WorldWideScience

Sample records for beta-delayed proton emitters

  1. Beta-delayed proton emitter $^{113}Xe$

    CERN Document Server

    Hagberg, E; Jonson, B; Jørgensen, B; Kugler, E; Mowinckel, T

    1973-01-01

    The ISOLDE facility at the CERN synchrocyclotron has been used for extending the series of beta -delayed proton emitters in xenon to masses lighter than those previously observed (/sup 115,117/Xe). Owing to the rapid decrease of the yields, experiments with solid-state counters were inconclusive, and instead a new and much more sensitive method based on nuclear emulsions was developed. The mass range 111-114 showed one new activity, /sup 113/Xe, with a half-life of 2.8+or-0.2 sec. From measurements of the track lengths for a total of 1130 protons from /sup 113/Xe it was possible to determine the energy spectrum. The results extend the systematics of beta -strength functions in the light xenon isotopes. (19 refs).

  2. A detection system for very low-energy protons from {beta}-delayed proton decay

    Energy Technology Data Exchange (ETDEWEB)

    Spiridon, A.; Pollacco, E.; Trache, L.; Simmons, E.; McCleskey, M.; Roeder, B. T.; Tribble, R. E.; Pascovici, G.; Riallot, M.; Mols, J. P.; Kebbiri, M. [Cyclotron Institute, Texas A and M University, College Station, TX 77843-3366 (United States); CEA/IRFU Saclay, Gif-sur-Yvette (France); Cyclotron Institute, Texas A and M University, College Station, TX 77843-3366 (United States); Institut fuer Kernphysik der Universitaet zu Koeln, D-50937 Koeln (Germany); CEA/IRFU Saclay, Gif-sur-Yvette (France)

    2012-11-20

    We have recently developed a gas based detection system called AstroBox, motivated by nuclear astrophysics studies. The goal was to detect very low-energy protons from {beta}-delayed p-decay with reduced beta background and improved energy resolution. The detector was tested using the {beta}-delayed proton-emitter 23Al previously studied with a set-up based on thin double-sided Si strip detectors. The proton spectrum obtained with AstroBox showed no beta background down to {approx}80 keV. The low energy (206 keV, 267 keV) proton peaks were positively identified, well separated, and the resolution was improved.

  3. Beta-delayed proton activities: 147Dy and 149Er

    International Nuclear Information System (INIS)

    Toth, K.S.; Moltz, D.M.; Schloemer, E.C.; Cable, M.D.; Avignone, F.T. III; Ellis-Akovali, Y.A.

    1984-01-01

    The present paper discusses mainly the β-delayed proton spectra of 147 Dy and of the hitherto unknown isotope, 149 Er. However, following the submittal of the abstract for this conference we have now observed delayed protons following the decay of 145 Dy. Additionally, we have identified a 0.5-s delayed-proton emitter and tentatively assign it to the new isotope, 151 Yb

  4. Beta-delayed proton emission from {sup 20}Mg

    Energy Technology Data Exchange (ETDEWEB)

    Lund, M.V.; Fynbo, H.O.U.; Howard, A.M.; Kirsebom, O.S.; Munch, M.; Riisager, K. [Aarhus University, Department of Physics and Astronomy, Aarhus C (Denmark); Andreyev, A.; Wadsworth, R. [University of York, Department of Physics, York (United Kingdom); Borge, M.J.G. [CSIC, Instituto de Estructura de la Materia, Madrid (Spain); CERN, ISOLDE, PH Department, Geneva 23 (Switzerland); Cederkaell, J. [Lund University, Department of Nuclear Physics, Lund (Sweden); Witte, H. de; Huyse, M.; Duppen, P. van [Instituut voor Kern- en Stralingsfysica, KU-Leuven, Leuven (Belgium); Fraile, L.M.; Vedia, V. [Universidad Complutense de Madrid, CEI Moncloa, Facultad de Ciencias Fisicas, Madrid (Spain); Greenlees, P.T.; Konki, J.; Rahkila, P. [University of Helsinki, Helsinki Institute of Physics, Helsinki (Finland); University of Jyvaeskylae, Department of Physics, Jyvaeskylae (Finland); Harkness-Brennan, L.J.; Judson, D.S.; Page, R.D. [University of Liverpool, Department of Physics, Oliver Lodge Laboratory, Liverpool (United Kingdom); Jonson, B.; Lindberg, S.; Nilsson, T. [Chalmers University of Technology, Department of Physics, Goeteborg (Sweden); Kurcewicz, J.; Madurga, M.; Rapisarda, E. [CERN, ISOLDE, PH Department, Geneva (Switzerland); Lazarus, I.; Pucknell, V. [STFC Daresbury, Daresbury, Warrington (United Kingdom); Lica, R. [CERN, ISOLDE, PH Department, Geneva (Switzerland); ' ' Horia Hulubei' ' National Institute of Physics and Nuclear Engineering, Magurele (Romania); Marginean, N.; Marginean, R.; Mihai, C.; Negret, A.; Pascu, S.; Rotaru, F.; Stanoiu, M.; Turturica, A. [' ' Horia Hulubei' ' National Institute of Physics and Nuclear Engineering, Magurele (Romania); Marroquin, I.; Nacher, E.; Perea, A.; Tengblad, O. [CSIC, Instituto de Estructura de la Materia, Madrid (Spain); Sotty, C. [Instituut voor Kern- en Stralingsfysica, KU-Leuven, Leuven (Belgium); ' ' Horia Hulubei' ' National Institute of Physics and Nuclear Engineering, Magurele (Romania); Warr, N. [Universitaet Koeln, Institut fuer Kernphysik, Koeln (Germany); Collaboration: IDS Collaboration

    2016-10-15

    Beta-delayed proton emission from {sup 20} Mg has been measured at ISOLDE, CERN, with the ISOLDE Decay Station (IDS) setup including both charged-particle and gamma-ray detection capabilities. A total of 27 delayed proton branches were measured including seven so far unobserved. An updated decay scheme, including three new resonances above the proton separation energy in {sup 20}Na and more precise resonance energies, is presented. Beta-decay feeding to two resonances above the Isobaric Analogue State (IAS) in {sup 20}Na is observed. This may allow studies of the 4032.9(2.4) keV resonance in {sup 19}Ne through the beta decay of {sup 20}Mg, which is important for the astrophysically relevant reaction {sup 15}O(α, γ){sup 19}Ne. Beta-delayed protons were used to obtain a more precise value for the half-life of {sup 20}Mg, 91.4(1.0) ms. (orig.)

  5. A detection system for very low-energy protons from β-delayed proton decay

    International Nuclear Information System (INIS)

    Spiridon, A.; Pollacco, E.; Trache, L.; Simmons, E.; McCleskey, M.; Roeder, B. T.; Tribble, R. E.; Pascovici, G.; Riallot, M.; Mols, J. P.; Kebbiri, M.

    2012-01-01

    We have recently developed a gas based detection system called AstroBox, motivated by nuclear astrophysics studies. The goal was to detect very low-energy protons from β-delayed p-decay with reduced beta background and improved energy resolution. The detector was tested using the β-delayed proton-emitter 23Al previously studied with a set-up based on thin double-sided Si strip detectors. The proton spectrum obtained with AstroBox showed no beta background down to ∼80 keV. The low energy (206 keV, 267 keV) proton peaks were positively identified, well separated, and the resolution was improved.

  6. Selected aspects in the structure of beta-delayed particle spectra

    International Nuclear Information System (INIS)

    Honkanen, J.; Aeystoe, J.; Eskola, K.

    1986-01-01

    Some weak beta-delayed particle emitters in the T z =-3/2, -1, -1/2, +1/2 and +5/2 series are reviewed. Selected features of the delayed particle emission are discussed in terms of experimental delayed particle data and (p,γ), (p,p') and (p,n) reaction data. Experimental beta transition strengths are compared with the existing complete shell-model calculations for the sd-shell nuclei. The effect of the Gamow-Teller giant resonance on the structure of the delayed particle spectra is considered. The correlation between the widths of two decay channels, protons and alpha particles, and the preceeding beta decay is studied in the case of the 40 Sc decay. (orig.)

  7. Decay Spectroscopy for Nuclear Astrophysics: {beta}-delayed Proton Decay

    Energy Technology Data Exchange (ETDEWEB)

    Trache, L.; Simmons, E.; Spiridon, A.; McCleskey, M.; Roeder, B. T.; Tribble, R. E. [Texas A and M University, College Station, TX 77845 (United States); Saastamoinen, A.; Jokinen, A.; Aysto, J. [University of Jyvaskyla, Jyvaskyla (Finland); Davinson, T.; Woods, P. J. [University of Edinburgh, Edinburgh (United Kingdom); Pollacco, E.; Kebbiri, M. [CEA/IRFU Saclay (France); Pascovici, G. [IKP, Universitaet zu Koeln (Germany)

    2011-11-30

    Decay spectroscopy is one of the oldest indirect methods in nuclear astrophysics. We have developed at TAMU techniques to measure beta- and beta-delayed proton decay of sd-shell, proton-rich nuclei. The short-lived radioactive species are produced in-flight, separated, then slowed down (from about 40 MeV/u) and implanted in the middle of very thin Si detectors. These allowed us to measure protons with energies as low as 200 keV from nuclei with lifetimes of 100 ms or less. At the same time we measure gamma-rays up to 8 MeV with high resolution HPGe detectors. We have studied the decay of {sup 23}Al, {sup 27}P, {sup 31}Cl, all important for understanding explosive H-burning in novae. The technique has shown a remarkable selectivity to beta-delayed charged-particle emission and works even at radioactive beam rates of a few pps. The states populated are resonances for the radiative proton capture reactions {sup 22}Na(p,{gamma}){sup 23}Mg(crucial for the depletion of {sup 22}Na in novae), {sup 26m}Al(p,{gamma}){sup 27}Si and {sup 30}P(p,{gamma}){sup 31}S(bottleneck in novae and XRB burning), respectively. More recently we have radically improved the technique using a gas based detector we call AstroBox.

  8. Beta-delayed proton decay of 73Sr

    International Nuclear Information System (INIS)

    Batchelder, J.C.; Moltz, D.M.; Ognibene, T.J.; Rowe, M.W.; Tighe, R.J.; Cerny, J.

    1993-01-01

    The T z =-3/2, A=4n+1 nuclide 73 Sr produced in the 40 Ca( 36 Ar,3n) reaction has been observed via beta-delayed proton emission. A single proton group at a laboratory energy of 3.75±0.04 MeV has been observed, corresponding to decay of the T=3/2 isobaric analog state in 73 Rb to the ground state of 72 Kr. Combining this measurement with a Coulomb displacement energy calculation yields a mass excess for 73 Sr of -31.82±0.24 MeV based on a predicted mass for 72 Kr of -53.94±0.24 MeV

  9. Additional beta-delayed protons from the T/sub z/ = -3/2 nuclei 21Mg, 25Si, 29S, and 41Ti

    International Nuclear Information System (INIS)

    Zhou, Z.Y.; Schloemer, E.C.; Cable, M.D.; Ahmed, M.; Reiff, J.E.; Cerny, J.

    1985-01-01

    Beta-delayed proton emission has proven to be a useful tool for understanding nuclei far from stability. Most of the beta decay strength is concentrated at and below the isobaric analog state (IAS) of the parent nucleus (precursor) ground state. Identification of beta strength to states above the IAS is important not only because it provides additional tests of nuclear models of beta decay, but also because proton emission from such beta daughter nuclei frequently constitutes an important component of the background in searches for more exotic nuclei. Therefore the authors have re-measured the beta-delayed proton spectra of four T/sub z/ = -3/2 nuclei: 21 Mg, 25 Si, 29 S, and 41 Ti. Fourteen previously unreported proton groups were observed and beta decay branching ratios were derived for each

  10. Search for $\\beta$-delayed protons from $^{11}$Be

    CERN Multimedia

    $\\beta$-delayed proton emission from $^{11}$Be will be a very rare process. It is believed to decay directly into continuum states. This would imply that it will be a sensitive probe of the halo structure of the one-neutron halo nucleus $^{11}$Be. We propose to improve existing (unpublished) limits on this decay mode by two orders of magnitude. Our earlier experience at ISOLDE indicates that the required intensity and purity of the source can be obtained. The branching ratio will be measured by counting the number of $^{10}$Be atoms produced via accelerator mass spectrometry.

  11. Spherical proton emitters

    International Nuclear Information System (INIS)

    Berg, S.; Semmes, P.B.; Nazarewicz, W.

    1997-01-01

    Various theoretical approaches to proton emission from spherical nuclei are investigated, and it is found that all the methods employed give very similar results. The calculated decay widths are found to be qualitatively insensitive to the parameters of the proton-nucleus potential, i.e., changing the potential parameters over a fairly large range typically changes the decay width by no more than a factor of ∼3. Proton half-lives of observed heavy proton emitters are, in general, well reproduced by spherical calculations with the spectroscopic factors calculated in the independent quasiparticle approximation. The quantitative agreement with experimental data obtained in our study requires that the parameters of the proton-nucleus potential be chosen carefully. It also suggests that deformed proton emitters will provide invaluable spectroscopic information on the angular momentum decomposition of single-proton orbitals in deformed nuclei. copyright 1997 The American Physical Society

  12. Studies of $\\beta$-delayed two-proton emission : The cases of $^{31}$Ar and $^{35}$Ca

    CERN Multimedia

    Riisager, K; Jokinen, A; Canchel, G; Heinz, A M; Jonson, B N G; Dominguez reyes, R R; Koldste, G T; Fraile prieto, L M; Nilsson, T; Audirac, L L

    2008-01-01

    We propose to perform detailed studies of the decays of the two dripline nuclei $^{31}$Ar and $^{35}$Ca. This will allow an in-depth study in the process of $\\beta$-delayed two-proton emission ($\\beta$2p); as well as provide important information on resonances in $^{30}$S and $^{34}$Ar relevant for the astrophysical rp-process.

  13. Half-life calculation of one-proton emitters with a shell model potential

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, M. M.; Duarte, S. B. [Centro Brasileiro de Pesquisas Fisicas-CBPF/MCT Rua Dr. Xavier Sigaud, 150, 22290-180, Rio de Janeiro-RJ (Brazil); Teruya, N. [Departamento de Fisica, Universidade Federal da Paraiba - UFPB Campus de Joao Pessoa, 58051-970, Joao Pessoa - PB (Brazil)

    2013-03-25

    The accumulated amount of data for half-lives of proton emitters still remains a challenge to the ability of nuclear models to reproduce them consistently. These nuclei are far from beta stability line in a region where the validity of current nuclear models is not guaranteed. A nuclear shell model is introduced to the calculation of the nuclear barrier of less deformed proton emitters. The predictions using the proposed model are in good agreement with the data, with the advantage of have used only a single parameter in the model.

  14. Beta-delayed proton emission in neutron-deficient lanthanide isotopes

    International Nuclear Information System (INIS)

    Wilmarth, P.A.

    1988-01-01

    Forty-two β-delayed proton precursors with 56≤Z≤71 and 63≤N≤83 were produced in heavy-ion reactions at the Lawrence Berkeley Laboratory SuperHILAC and their radioactive decay properties studied at the on-line mass separation facility OASIS. Twenty-five isotopes and eight delayed proton branches were identified for the first time. Delayed proton energy spectra and proton coincident γ-ray and x-ray spectra were measured for all precursors. In a few cases, proton branching ratios were also determined. The precursor mass numbers were determined by the separator, while the proton coincident x-ray energies provided unambiguous Z identifications. The proton coincident γ-ray intensities were used to extract final state branching ratios. Proton emission from ground and isomeric states was observed in many cases. The majority of the delayed proton spectra exhibited the smooth bell-shaped distribution expected for heavy mass precursors. The experimental results were compared to statistical model calculations using standard parameter sets. Calculations using Nilsson model/RPA β-strength functions were found to reproduce the spectral shapes and branching ratios better than calculations using either constant or gross theory β-strength functions. Precursor half-life predictions from the Nilsson model/RPA β-strength functions were also in better agreement with the measured half-lives than were gross theory predictions. The ratios of positron coincident proton intensities to total proton intensities were used to determine Q/sub EC/-B/sub p/ values for several precursors near N=82. The statistical model calculations were not able to reproduce the experimental results for N=81 precursors. 154 refs., 82 figs., 19 tabs

  15. AstroBox: A novel detection system for very low-energy protons from β-delayed proton decay

    Energy Technology Data Exchange (ETDEWEB)

    Pollacco, E., E-mail: epollacco@cea.fr [IRFU, CEA Saclay, Gif-sur-Yvette (France); Trache, L. [Cyclotron Institute, Texas A and M University, College Station, TX 77843-3366 (United States); National Institute of Physics and Nuclear Engineering, Bucharest-Magurele, RO-077125 (Romania); Simmons, E.; Spiridon, A.; McCleskey, M. [Cyclotron Institute, Texas A and M University, College Station, TX 77843-3366 (United States); Roeder, B.T., E-mail: broeder@comp.tamu.edu [Cyclotron Institute, Texas A and M University, College Station, TX 77843-3366 (United States); Saastamoinen, A.; Tribble, R.E. [Cyclotron Institute, Texas A and M University, College Station, TX 77843-3366 (United States); Pascovici, G. [National Institute of Physics and Nuclear Engineering, Bucharest-Magurele, RO-077125 (Romania); Kebbiri, M.; Mols, J.P.; Raillot, M. [IRFU, CEA Saclay, Gif-sur-Yvette (France)

    2013-09-21

    An instrument, AstroBox, has been developed to perform low energy proton spectroscopy from β-delayed proton emitters of interest to astrophysics studies. Energetic precursor nuclei are identified and stopped in the gas volume of the detector. The subsequent β or β-proton decay traces ionized paths in the gas. The ionization electrons are drifted in an electric field and are amplified with a Micro Pattern Gas Amplifier Detector (MPGAD). The system was tested in-beam using the β-delayed proton-emitter {sup 23}Al, which was produced with the p({sup 24}Mg,{sup 23}Al)2n reaction and separated with the Momentum Achromat Recoil Spectrometer (MARS) at the Cyclotron Institute at Texas A and M University. Off-beam proton spectra have essentially no β background down to ∼100keV and have a resolution of ∼15keV (fwhm) for proton-decay lines at E{sub p}=197 and 255 keV. Lines with βp-branching as low as 0.02% are observed. In addition, the device also gives good mass and charge resolution for energetic heavy ions measured in-beam.

  16. The Mechanism of $\\beta$-Delayed Two-Proton Emission

    CERN Multimedia

    2002-01-01

    The nucleus $^{31}$Ar seems to be the most prolific ${\\beta}$-2p precursor known to date and is at the same time the one with the largest production yields at ISOLDE, where the most sensitive experiments can be done. Our purpose with this experiment is to study the ${\\beta}$-2p branches in detail, search for ${\\beta}$-3p events, place them in the decay scheme and obtain information on the decay mechanism for ${\\beta}$-2p via the energy distribution and the angular correlation between the two protons. As a by product we shall also resolve existing inconsistencies in the level scheme.\\\\ \\\\ The nucleus $^{31}$Ar, produced in a cold plasma ion source unit by the impact of a 1 GeV proton beam of 0.5 Hz frequency, had an average yield over one week of 1.5 $^{31}$Ar atoms/s. The beam passed through the central hole of an annular Si detector ($\\Omega$ = 4.3~\\%) and stopped in a thin carbon foil tilted 45$^o$ with respect to the beam direction. A 70~\\% coaxial HPGe-detector ($\\Omega$~=~7.4~\\%) was located opposite to ...

  17. Beta-delayed proton decay in the lanthanide region

    International Nuclear Information System (INIS)

    Nitschke, J.M.; Wilmarth, P.A.; Gilat, J.; Moeller, P.; Toth, K.S.

    1987-09-01

    A total of 24 new β-delayed proton precursors and several new decay branches in the region of 56 151 Yb, 149 Er, and 147 Dy, pronounced structure in the proton spectra has been observed. An interpretation of this structure in the framework of ''doorway'' states is proposed. 25 refs., 6 figs., 1 tab

  18. Measurement of the most exotic beta-delayed neutron emitters at N=50 and N=126

    Science.gov (United States)

    Dillmann, Iris

    2017-09-01

    Beta-delayed neutron (βn)-emission will be the dominant decay mechanism of neutron-rich nuclei and plays an important role in the stellar nucleosynthesis of heavy elements in the ``r process''. It leads to a detour of the material β-decaying back to stability and the released neutrons increase the neutron-to-seed ratio, and are re-captured during the freeze-out phase and thus influence the final solar r-abundance curve. Thus the neutron branching ratio of very neutron-rich isotopes is a crucial parameter in astrophysical simulations. In addition, β-decay half-lives can be deduced from the time-dependent detection of βn's. I will talk about two recent experimental campaigns. The neutron detector BELEN was used at GSI Darmstadt to measure half-lives and neutron-branching ratios of the heaviest presently accessible βn-emitters at N=126. For isotopes between 204Au and 220Bi nine half-lives and eight neutron-branching ratios were measured for the first time and provide an important input for benchmarking theoretical models in this mass region. Its successor is the BRIKEN detector (``Beta-delayed neutron measurements at RIKEN for nuclear structure, astrophysics, and applications''), the most efficient neutron detector used so far for nuclear structure studies. In conjunction with two clover detectors and the ``Advanced Implantation Detector Array'' (AIDA) the setup has been used a few months ago to measure the most neutron-rich isotopes around 78Ni, 132Sn, and the Rare Earth Region. Some preliminary results are shown from the campaign covering the 78Ni region where the neutron-branching ratio of 78Ni and 28 more isotopes were measured for the first time, as well as the half-lives of 20 isotopes. The BRIKEN campaign aims to (re-)measure almost all βn-emitters between 76Co and 167Eu, many of them for the first time. An extension of the campaign to lighter masses is planned. This work has been supported by the NSERC and NRC in Canada, the US DOE, the Spanish

  19. Decays of 22Al and 26P: discovery of beta-delayed two-proton radioactivity

    International Nuclear Information System (INIS)

    Cable, M.D.

    1983-02-01

    A helium-jet system and the 24 Mg( 3 He,p4n) 22 Al and 28 Si( 3 He,p4n) 26 P reactions have been used to discover the only known odd-odd, T/sub Z/ = -2 nuclides, 22 Al(t/sub 1/2/ approx. 70ms) and 26 P(t/sub 1/2/ approx. 20 ms). Observations of beta-delayed protons from each isotope (laboratory energies 7.839 +- 0.015 MeV and 8.149 +- 0.021 MeV for 22 Al and 7.269 +- 0.015 MeV and 6.827 +- 0.050 MeV for 26 P) established the existence of these nuclides and provided a measurement of the mass excesses of the lowest T = 2 states in their beta decay daughters, 22 Mg and 26 Si (13.650 +- 0.015 MeV and 5.936 +- 0.015 MeV, respectively). Measurement of these masses confirmed that these T = 2 states were unbound to two-proton emission as had been predicted theoretically

  20. Study of the time and space distribution of {beta}{sup +} emitters from 80MeV/u carbon ion beam irradiation on PMMA

    Energy Technology Data Exchange (ETDEWEB)

    Agodi, C. [Laboratori Nazionali del Sud dell' INFN, Catania (Italy); Bellini, F. [Dipartimento di Fisica, Sapienza Universita di Roma, Roma (Italy); INFN Sezione di Roma, Roma (Italy); Cirrone, G.A.P. [Laboratori Nazionali del Sud dell' INFN, Catania (Italy); Collamati, F. [Dipartimento di Fisica, Sapienza Universita di Roma, Roma (Italy); INFN Sezione di Roma, Roma (Italy); Cuttone, G. [Laboratori Nazionali del Sud dell' INFN, Catania (Italy); De Lucia, E. [Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); De Napoli, M. [Laboratori Nazionali del Sud dell' INFN, Catania (Italy); Di Domenico, A.; Faccini, R.; Ferroni, F. [Dipartimento di Fisica, Sapienza Universita di Roma, Roma (Italy); INFN Sezione di Roma, Roma (Italy); Fiore, S. [Dipartimento di Fisica, Sapienza Universita di Roma, Roma (Italy); Gauzzi, P. [Dipartimento di Fisica, Sapienza Universita di Roma, Roma (Italy); INFN Sezione di Roma, Roma (Italy); Iarocci, E. [Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); Dipartimento di Scienze di Base e Applicate per l' Ingegneria, Sapienza Universita di Roma, Roma (Italy); Marafini, M., E-mail: michela.marafini@roma1.infn.it [Museo Storico della Fisica e Centro Studi e Ricerche ' E. Fermi' , Roma (Italy); Mattei, I. [Dipartimento di Fisica, Roma Tre Universita di Roma, Roma (Italy); Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); Paoloni, A. [Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); and others

    2012-07-15

    Proton and carbon ion therapy is an emerging technique used for the treatment of solid cancers. The monitoring of the dose delivered during such treatments and the on-line knowledge of the Bragg peak position is still a matter of research. A possible technique exploits the collinear 511keV photons produced by positrons annihilation from {beta}{sup +} emitters created by the beam. This paper reports rate measurements of the 511keV photons emitted after the interactions of a 80MeV/u fully stripped carbon ion beam at the Laboratori Nazionali del Sud (LNS) of INFN, with a poly-methyl methacrylate target. The time evolution of the {beta}{sup +} rate was parametrized and the dominance of {sup 11}C emitters over the other species ({sup 13}N, {sup 15}O, {sup 14}O) was observed, measuring the fraction of carbon ions activating {beta}{sup +} emitters to be (10.3{+-}0.7) Multiplication-Sign 10{sup -3}. The average depth in the PMMA of the positron annihilation from {beta}{sup +} emitters was also measured, D{sub {beta}{sup +}}=5.3{+-}1.1mm, to be compared to the expected Bragg peak depth D{sub Bragg}=11.0{+-}0.5mm obtained from simulations.

  1. Simulation study of electron cloud induced instabilities and emittance growth for the CERN Large Hadron Collider proton beam

    CERN Document Server

    Benedetto, Elena; Schulte, Daniel; Rumolo, Giovanni

    2005-01-01

    The electron cloud may cause transverse single-bunch instabilities of proton beams such as those in the Large Hadron Collider (LHC) and the CERN Super Proton Synchrotron (SPS). We simulate these instabilities and the consequent emittance growth with the code HEADTAIL, which models the turn-by-turn interaction between the cloud and the beam. Recently some new features were added to the code, in particular, electric conducting boundary conditions at the chamber wall, transverse feedback, and variable beta functions. The sensitivity to several numerical parameters has been studied by varying the number of interaction points between the bunch and the cloud, the phase advance between them, and the number of macroparticles used to represent the protons and the electrons. We present simulation results for both LHC at injection and SPS with LHC-type beam, for different electron-cloud density levels, chromaticities, and bunch intensities. Two regimes with qualitatively different emittance growth are observed: above th...

  2. Decay spectroscopy for nuclear astrophysics: β- and β-delayed proton decay

    Science.gov (United States)

    Trache, L.; Banu, A.; Hardy, J. C.; Iacob, V. E.; McCleskey, M.; Roeder, B. T.; Simmons, E.; Spiridon, A.; Tribble, R. E.; Saastamoinen, A.; Jokinen, A.; Äysto, J.; Davinson, T.; Lotay, G.; Woods, P. J.; Pollacco, E.

    2012-02-01

    In several radiative proton capture reactions important in novae and XRBs, the resonant parts play the capital role. We use decay spectroscopy techniques to find these resonances and study their properties. We have developed techniques to measure beta- and beta-delayed proton decay of sd-shell, proton-rich nuclei produced and separated with the MARS recoil spectrometer of Texas A&M University. The short-lived radioactive species are produced in-flight, separated, then slowed down (from about 40 MeV/u) and implanted in the middle of very thin Si detectors. This allows us to measure protons with energies as low as 200 keV from nuclei with lifetimes of 100 ms or less. At the same time we measure gamma-rays up to 8 MeV with high resolution HPGe detectors. We have studied the decay of 23Al, 27P, 31Cl, all important for understanding explosive H-burning in novae. The technique has shown a remarkable selectivity to beta-delayed charged-particle emission and works even at radioactive beam rates of a few pps. The states populated are resonances for the radiative proton capture reactions 22Na(p,γ)23Mg (crucial for the depletion of 22Na in novae), 26mAl(p,γ)27Si and 30P(p,γ)31S (bottleneck in novae and XRB burning), respectively. Lastly, results with a new detector that allowed us to measure down to about 80 keV proton energy are announced.

  3. Decay spectroscopy for nuclear astrophysics: β- and β-delayed proton decay

    International Nuclear Information System (INIS)

    Trache, L; Banu, A; Hardy, J C; Iacob, V E; McCleskey, M; Roeder, B T; Simmons, E; Spiridon, A; Tribble, R E; Saastamoinen, A; Jokinen, A; Äysto, J; Davinson, T; Lotay, G; Woods, P J; Pollacco, E

    2012-01-01

    In several radiative proton capture reactions important in novae and XRBs, the resonant parts play the capital role. We use decay spectroscopy techniques to find these resonances and study their properties. We have developed techniques to measure beta- and beta-delayed proton decay of sd-shell, proton-rich nuclei produced and separated with the MARS recoil spectrometer of Texas A and M University. The short-lived radioactive species are produced in-flight, separated, then slowed down (from about 40 MeV/u) and implanted in the middle of very thin Si detectors. This allows us to measure protons with energies as low as 200 keV from nuclei with lifetimes of 100 ms or less. At the same time we measure gamma-rays up to 8 MeV with high resolution HPGe detectors. We have studied the decay of 23 Al, 27 P, 31 Cl, all important for understanding explosive H-burning in novae. The technique has shown a remarkable selectivity to beta-delayed charged-particle emission and works even at radioactive beam rates of a few pps. The states populated are resonances for the radiative proton capture reactions 22 Na(p,γ) 23 Mg (crucial for the depletion of 22 Na in novae), 26m Al(p,γ) 27 Si and 30 P(p,γ) 31 S (bottleneck in novae and XRB burning), respectively. Lastly, results with a new detector that allowed us to measure down to about 80 keV proton energy are announced.

  4. Proton radioactivity: the case for 53m Co proton-emitter isomer

    International Nuclear Information System (INIS)

    Tavares, O.A.P.; Medeiros, E.L.

    2010-01-01

    The partial proton emission half-life for 53m Co unstable isomer is re-examined in the framework of a semiempirical model based on tunneling through a Coulomb-plus centrifugal- plus-overlapping potential barrier within the spherical nucleus approximation. It is shown that the known measured half-life value of 17 s is compatible with a large prolate shape for 53m Co proton emitter and a high angular momentum ι = 11 assigned to the proton transition to the ground-state of 52 Fe. (author)

  5. Method validation to determine total alpha beta emitters in water samples using LSC

    International Nuclear Information System (INIS)

    Al-Masri, M. S.; Nashawati, A.; Al-akel, B.; Saaid, S.

    2006-06-01

    In this work a method was validated to determine gross alpha and beta emitters in water samples using liquid scintillation counter. 200 ml of water from each sample were evaporated to 20 ml and 8 ml of them were mixed with 12 ml of the suitable cocktail to be measured by liquid scintillation counter Wallac Winspectral 1414. The lower detection limit by this method (LDL) was 0.33 DPM for total alpha emitters and 1.3 DPM for total beta emitters. and the reproducibility limit was (± 2.32 DPM) and (±1.41 DPM) for total alpha and beta emitters respectively, and the repeatability limit was (±2.19 DPM) and (±1.11 DPM) for total alpha and beta emitters respectively. The method is easy and fast because of the simple preparation steps and the large number of samples that can be measured at the same time. In addition, many real samples and standard samples were analyzed by the method and showed accurate results so it was concluded that the method can be used with various water samples. (author)

  6. Development of new microencapsulated beta emitters for internal radiotherapy

    International Nuclear Information System (INIS)

    Perdrisot, R.; Monteil, J.; Le Jeune, J.J.; Pouliquen, D.; Jallet, P.; Beau, P.; Lepape, A.

    1993-01-01

    We have developed new microencapsulated beta emitter radiotracers which could be used in nuclear medicine for selective internal radiotherapy. Their efficacy was evaluated on B16 melanoma tumor model in mice, using phosphorus 31 spectroscopy. This kind of tracer would allow a precise targetting of beta irradiation

  7. Improvements to the on-line mass separator, RAMA, and the beta-delayed charged-particle emission of proton-rich sd shell nuclei

    International Nuclear Information System (INIS)

    Ognibene, T.J.

    1996-03-01

    To overcome the extreme difficulties encountered in the experimental decay studies of proton drip line nuclei, several techniques have been utilized, including a helium-jet transport system, particle identification detectors and mass separation. Improvements to the ion source/extraction region of the He-jet coupled on-line Recoil Atom Mass Analyzer (RAMA) and its target/ion source coupling resulted in significant increases in RAMA efficiencies and its mass resolution, as well as reductions in the overall transit time. At the 88-Inch Cyclotron at LBNL, the decays of 31 Cl, 27 P and 28 P, with half-lives of 150 msec, 260 msec and 270.3 msec, respectively, were examined using a he-jet and low-energy gas ΔE-gas ΔE-silicon E detector telescopes. Total beta-delayed proton branches of 0.3% and 0.07% in 31 Cl and 27 P, respectively, were estimated. Several proton peaks that had been previously assigned to the decay of 31 Cl were shown to be from the decay of 25 Si. In 27 P, two proton groups at 459 ± 14 keV and 610 ± 11 keV, with intensities of 7 ± 3% and 92 ± 4% relative to the main (100%) group were discovered. The Gamow-Teller component of the preceding beta-decay of each observed proton transition was compared to results from shell model calculations. Finally, a new proton transition was identified, following the β-decay of 28 P, at 1,444 ± 12 keV with a 1.7 ± 0.5% relative intensity to the 100% group. Using similar low-energy detector telescopes and the mass separator TISOL at TRIUMF, the 109 msec and 173 msec activities, 17 Ne and 33 Ar, were studied. A new proton group with energy 729 ± 15 keV was observed following the beta-decay of 17 Ne. Several discrepancies between earlier works as to the energies, intensities and assignments of several proton transitions from 17 Ne and 33 Ar were resolved

  8. Proton radioactivity: the case for {sup 53m} Co proton-emitter isomer

    Energy Technology Data Exchange (ETDEWEB)

    Tavares, O.A.P.; Medeiros, E.L., E-mail: emil@cbpf.b

    2010-07-01

    The partial proton emission half-life for {sup 53m}Co unstable isomer is re-examined in the framework of a semiempirical model based on tunneling through a Coulomb-plus centrifugal- plus-overlapping potential barrier within the spherical nucleus approximation. It is shown that the known measured half-life value of 17 s is compatible with a large prolate shape for {sup 53m}Co proton emitter and a high angular momentum {iota} = 11 assigned to the proton transition to the ground-state of {sup 52}Fe. (author)

  9. Search for beta-delayed protons from {sup 11}Be

    Energy Technology Data Exchange (ETDEWEB)

    Forstner, Oliver [VERA Laboratory, University of Vienna (Austria); Stefan-Meyer-Institut, Austrian Academy of Sciences, Vienna (Austria); CERN, Geneva (Switzerland); Collaboration: IS541-Collaboration

    2014-07-01

    The one-neutron halo nucleus {sup 11}Be can emit a proton in a beta decay of the halo neutron. However, due to the Q-value of this decay channel (280.7±0.3 keV) the expected branching ratio will be very low - most estimates are a few times 10{sup -8} - and the detection of the outgoing proton with a kinetic energy of a few hundred keV is challenging. Therefore our attempt was to detect the remaining nucleus {sup 10}Be with the help of accelerator mass spectrometry (AMS). AMS is a highly sensitive tool to detect radioisotopes at the ultra-trace level. A beam of {sup 11}Be ions was produced at the ISOLDE facility at CERN and implanted in a collection sample. The sample was transferred to the VERA AMS facility at the University of Vienna where the {sup 10}Be content was determined. In my talk I present details of the experiment and results of the successful detection of this rare decay channel.

  10. Standardization of low energy beta and beta-gamma complex emitters by the tracer and the efficiency extrapolation methods

    International Nuclear Information System (INIS)

    Sahagia, M.

    1978-01-01

    The absolute standardization of radioactive solutions of low energy beta emitters and beta-gamma emitters with a high probability of disintegration to the ground state is described; the tracer and the efficiency extrapolation methods were used. Both types of radionuclides were mathematically and physically treated in an unified manner. The theoretical relations between different beta spectra were calculated according to Williams' model and experimentally verified for: 35 S + 60 Co, 35 S + 95 Nb, 147 Pm + 60 Co, 14 C + 95 Nb and two beta branches of 99 Mo. The optimum range of beta efficiency variation was indicated. The basic supposition that all beta efficieny tend to unity in the same time was experimentally verified, using two 192 Ir beta branches. Four computer programs, written in the FORTRAN IV language, were elaborated, for the adequate processing of the experimental data. Good precision coefficients according to international standards were obtained in the absolute standardization of 35 S, 147 Pm, 99 Mo solutions. (author)

  11. $\\beta$-delayed fission in proton-rich nuclei in the lead region

    CERN Document Server

    AUTHOR|(CDS)2085005; Huyse, Mark; Popescu, Lucia

    Nuclear fission is the breakup of an atomic nucleus into two (sometimes three) fragments, thereby releasing a large amount of energy. Soon after its discovery in the late 1930’s, the gross properties of the fission phenomenon were explained by macroscopic nuclear models. Certain features however, such as asymmetric fission-fragment mass distributions in the actinide region, require the inclusion of microscopic effects. This interplay of the microscopic motion of individual nucleons on this macroscopic process is, until today, not yet fully understood. The phenomenon of fission has therefore been of recurring interest for both theoretical and experimental studies. This thesis work focuses on the $\\beta$-delayed fission ($\\beta$DF) process, an excellent tool to study low-energy fission of exotic nuclei, which was discovered in 1966 in the actinide region. In this two-step process, a precursor nucleus first undergoes $\\beta$-decay to an excited level in the daughter nucleus, which may subsequently fission. Rec...

  12. Transverse Emittance Measurement and Preservation at the LHC

    CERN Document Server

    AUTHOR|(CDS)2082907

    The Large Hadron Collider (LHC) at CERN is a high energy storage ring that provides proton and heavy ion collisions to study fundamental particle physics. The luminosity production is closely linked to emittance preservation in the accelerator. The transverse emittance is the phase space density of the beam and should be conserved when the particle beam is transformed through the accelerator. Perturbing effects, however, can lead to emittance increase and hence luminosity degradation. Measuring the emittance growth is a complex task with high intensity beams and changing energies. The machine optics and the transverse beam size have to be measured as accurately as possible. Beta function measurements with k-modulation will be discussed. With this method the quadrupole focussing strength is varied and the resulting tune change is traced to determine the beta function at the quadrupole. A new k-modulation measurement tool was developed for the LHC. The fully automatic and online measurement system takes constra...

  13. Reference sources for the calibration of surface contamination monitors - Beta-emitters (maximum beta energy greater than MeV) and alpha-emitters (International Standard Publication ISO 8769:1988)

    International Nuclear Information System (INIS)

    Stefanik, J.

    2001-01-01

    This International Standard specifies the characteristics of reference sources of radioactive surface contamination, traceable to national measurement standards, for the calibration of surface contamination monitors. This International Standard relates to alpha-emitters and to beta-emitters of maximum beta energy greater than 0,15 MeV. It does not describe the procedures involved in the use of these reference sources for the calibration of surface contamination monitors. Such procedures are specified in IEC Publication 325 and other documents. This International Standard specifies reference radiations for the calibration of surface contamination monitors which take the form of adequately characterized large area sources specified, without exception, in terms of activity and surface emission rate, the evaluation of these quantities being traceable to national standards

  14. A critical study of emittance measurements of intense low-energy proton beams

    CERN Document Server

    Evans, Lyndon R

    1972-01-01

    The measurement of emittance in low energy proton beams suffers from two perturbing effects: 1) the neutralisation of the beam by backstreaming secondary electrons and 2) the space charge blowup of the beam sample between defining and analysing apparatus. An experimental study shows a significant change of the emittance orientation when bias is used to eliminate the secondary electrons. Biased and non-biased cases are also compared with computed dynamics including space charge. Criteria for the slit size and drift distance which make the space charge blow-up negligible are derived. In addition a transverse coherent oscillation of the proton beam, which was revealed the measurements, is discussed briefly. (11 refs).

  15. Non-stochastic effects of different energy beta emitters on pig and mouse skin

    International Nuclear Information System (INIS)

    Peel, D.M.; Hopewell, J.W.; Hansen, L.S.; Coggle, J.E.; Charles, M.W.; Wells, J.

    1982-01-01

    In this collaborative study skin areas of various sizes were irradiated with different energy beta emitters. In the post-irradiation period fields were examined for erythema, desquamation, ulceration and dermal necrosis. The aim of the study is to determine the threshold doses for the different biological reactions as a function of the energy of the radiation and the size of skin field irradiated. At St. Bartholomew's Hospital and Oxford the irradiation of mouse and pig skin was carried out using strontium-90 and thulium-170 sources. In addition, mice were irradiated with thallium-204, a slightly lower energy beta emitter than thulium. (author)

  16. Transverse emittance measurement and preservation at the LHC

    Energy Technology Data Exchange (ETDEWEB)

    Kuhn, Maria

    2016-06-20

    The Large Hadron Collider (LHC) at CERN is a high energy storage ring that provides proton and heavy ion collisions to study fundamental particle physics. The luminosity production is closely linked to emittance preservation in the accelerator. The transverse emittance is the phase space density of the beam and should be conserved when the particle beam is transformed through the accelerator. Perturbing effects, however, can lead to emittance increase and hence luminosity degradation. Measuring the emittance growth is a complex task with high intensity beams and changing energies. The machine optics and the transverse beam size have to be measured as accurately as possible. Beta function measurements with k-modulation are discussed. With this method the quadrupole focussing strength is varied and the resulting tune change is traced to determine the beta function at the quadrupole. A new k-modulation measurement tool was developed for the LHC. The fully automatic and online measurement system takes constraints of various systems such as tune measurement precision and powering limitations of the LHC superconducting circuits into account. With sinusoidal k-modulation record low beta function measurement uncertainties in the LHC have been reached. 2015 LHC beta function and β*, which is the beta function at the collision point, measurements with k-modulation will be presented. Wire scanners and synchrotron light monitors are presently used in the LHC to measure the transverse beam size. Accuracy and limitations of the LHC transverse profile monitors are discussed. During the 2012 LHC proton run it was found that wire scanner photomultiplier saturation added significant uncertainty on all measurements. A large discrepancy between emittances from wire scanners and luminosity was discovered but not solved. During Long Shutdown 1 the wire scanner system was upgraded with new photomultipliers. A thorough study of LHC wire scanner measurement precision in 2015 is presented

  17. Methodology to determine the efficiency of a beta emitter gases monitor

    International Nuclear Information System (INIS)

    Carvalho, Marcos Rodrigues de

    1995-01-01

    This work presents a methodology developed to determinate the efficiency of air monitors used to measure the concentration of beta emitters noble gases in nuclear power stations. Efficiency values, obtained by means of theoretical computation are compared with experimental values. The experimental part of the work was performed using three different point beta source, to simulate small amounts of gas uniformly distributed in small volume. The comparison shows that theoretical an experimental values agree within 4,2 % for 90 Sr + 90 Y, 204 Tl and 45 Ca beta sources. (author)

  18. Delayed Proton Emission in the A=70 Region, a Strobe for Level Density and Particle Width

    CERN Multimedia

    2002-01-01

    The delayed particle emission, which is a characteristic signature of the most exotic nuclei decay, provides a wide variety of spectroscopic information among which level density, and gives in some cases access to selected microscopic structures. In regard to these two aspects the $\\beta^+$-EC delayed proton emission in the A=70 neutron deficient mass region is of special interest to be investigated. Indeed, in this area located close to the proton drip line and along the N=Z line, the delayed proton emission constitutes an access to level density in the Q$_{EC}$-S$_p$ window of the emitting nucleus. Moreover, the unbound states populated by the EC process are expected to exhibit lifetimes in the vicinity of the K electronic shell filling time ($\\tau\\!\\sim\\!2\\times10^{-16}$s) and so the particle widths can be reached via proton X-ray coincidence measurements (PXCT). From theoretical approaches strongly deformed low-spin proton unbound levels which may be populated in the T$_Z$ = 1/2 precursors decay are predi...

  19. Study of beta-delayed neutron with proton-neutron QRPA plus statistical model

    International Nuclear Information System (INIS)

    Minato, Futoshi; Iwamoto, Osamu

    2015-01-01

    β-delayed neutron is known to be important for safety operation of nuclear reactor and prediction of elemental abundance after freeze-out of r-process. A lot of researches on it have been performed. However, the experimental data are far from complete since the lifetime of most of the relevant nuclei is so short that one cannot measure in a high efficiency. In order to estimate half-lives and delayed neutron emission probabilities of unexplored nuclei, we developed a new theoretical method which combines a proton-neutron quasi-particle random-phase-approximation and the Hauser-Feshbach statistical model. The present method reproduces experimentally known β-decay half-lives within a factor of 10 and about 40% of within a factor of 2. However it fails to reproduce delayed neutron emission probabilities. We discuss the problems and remedy for them to be made in future. (author)

  20. Rotational states of odd Z rare earth proton emitter 131Eu

    International Nuclear Information System (INIS)

    Aggarwal, Mamta

    2013-01-01

    Recent observation of proton radioactivity and rotational bands in 131 Eu and 141 Ho with large deformations β ≈ 0.3 and γ softness have already proven the study of excited states of deformed proton emitters a source of valuable information on the structure of proton decaying states and response of proton emitters on the stress of rotation. The rare earth nuclei below the N = 82 shell closure form one of the few regions of the nuclear chart where nuclear shapes are expected to change rapidly with coexistence of oblate and prolate shapes in some nuclei. We evaluate shapes and deformation of 131 Eu by combining classical collective properties of the liquid drop model with the quantum corrections due to shell effects via Strutinsky formalism adequately described in. Excited states are treated using statistical theory. Nuclear shapes and deformation are traced by minimizing free energy (F = E-TS) w.r.t. deformation parameters β from 0 to 0.4 in steps of 0.01 and γ from -180° (oblate with symmetry axis parallel to the rotation axis) to -120° (prolate with symmetry axis perpendicular to rotation axis) and then to -60° (oblate collective) to 0° (prolate non-collective)

  1. Magnetic moment of short lived {beta}-emitter {sup 24m}Al

    Energy Technology Data Exchange (ETDEWEB)

    Nishimura, D., E-mail: daiki@vg.phys.sci.osaka-u.ac.jp; Komurasaki, J.; Matsuta, K.; Mihara, M.; Matsumiya, R. [Osaka University, Department of Physics (Japan); Momota, S. [Kochi University of Technology (Japan); Ohtsubo, T. [Niigata University, Department of Physics (Japan); Izumikawa, T. [Niigata University, RI Center (Japan); Hirano, H. [Niigata University, Department of Physics (Japan); Kitagawa, A.; Kanazawa, M.; Torikoshi, M.; Sato, S. [National Institute of Radiological Sciences (Japan); Fukuda, M.; Ishikawa, D. [Osaka University, Department of Physics (Japan); Minamisono, T. [Fukui University of Technology (Japan); Watanabe, R.; Kubo, T. [Niigata University, Department of Physics (Japan); Nojiri, Y. [Kochi University of Technology (Japan); Alonso, J. R. [Lawrence Berkeley Laboratory (United States)

    2007-11-15

    The magnetic moment of short lived {beta}-emitter {sup 24m}Al (426 keV, I{sup {pi}} = 1{sup +}, T{sub 1/2} = 131 ms) has been measured by means of {beta}-NMR technique, for the first time. From the {beta}-NMR spectrum, the magnetic moment was determined as |{mu}({sup 24m}Al)|=(2.99{+-}0.09){mu}{sub N}. Combined with the known magnetic moment of the mirror partner {sup 24m}Na, the expectation value of < S{sub z} > is obtained to be (0.08 {+-} 0.12). These values are reproduced well by the shell model calculation.

  2. Revisiting the level scheme of the proton emitter 151Lu

    International Nuclear Information System (INIS)

    Wang, F.; Sun, B.H.; Liu, Z.; Scholey, C.; Eeckhaudt, S.; Grahn, T.; Greenlees, P.T.; Jones, P.; Julin, R.; Juutinen, S.; Kettelhut, S.; Leino, M.; Nyman, M.; Rahkila, P.; Saren, J.; Sorri, J.; Uusitalo, J.; Ashley, S.F.; Cullen, I.J.; Garnsworthy, A.B.; Gelletly, W.; Jones, G.A.; Pietri, S.; Podolyak, Z.; Steer, S.; Thompson, N.J.; Walker, P.M.; Williams, S.; Bianco, L.; Darby, I.G.; Joss, D.T.; Page, R.D.; Pakarinen, J.; Rigby, S.; Cullen, D.M.; Khan, S.; Kishada, A.; Gomez-Hornillos, M.B.; Simpson, J.; Jenkins, D.G.; Niikura, M.; Seweryniak, D.; Shizuma, Toshiyuki

    2015-01-01

    An experiment aiming to search for new isomers in the region of proton emitter 151 Lu was performed at the Accelerator Laboratory of the University of Jyväskylä (JYFL), by combining the high resolution γ-ray array JUROGAM, gas-filled RITU separator and GREAT detectors with the triggerless total data readout acquisition (TDR) system. In this proceeding, we revisit the level scheme of 151 Lu by using the proton-tagging technique. A level scheme consistent with the latest experimental results is obtained, and 3 additional levels are identified at high excitation energies. (author)

  3. Half-lives of proton emitters using relativistic mean field theory

    International Nuclear Information System (INIS)

    Sahu, Bidhubhusan; Patra, S. K.; Agarwalla, S. K.

    2011-01-01

    The proton radioactivity lifetimes of proton emitters from the ground and the isomeric states are calculated using the microscopic M3Y + Ex and R3Y + Ex (proposed) nucleon-nucleus interaction potentials. These interaction potentials are obtained by single folding the densities of the daughter nuclei supplemented by a zero-range pseudopotential. The quantum-mechanical-tunneling probability is calculated within the WKB approximation. The calculated results are found to be in good agreement with the experimental data for both the M3Y and R3Y interactions.

  4. Rapid method of identification of {beta}-ray emitters and of {beta}-radioactive impurity dosage (1961); Methode rapide d'identification des emetteurs-{beta} et de dosage d'impuretes radioactives-{beta} (1961)

    Energy Technology Data Exchange (ETDEWEB)

    Le Gallic, Y; Legrand, J; Grinberg, B [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1961-07-01

    We describe a simple method of radioactive analysis, which allows an accurate determination of maximal energies of {beta}-emitters, and detection and titration of radioactive impurities in radionuclides as well. The method described, which uses a plastic scintillator, is based on the fact that the curve obtained by plotting the number of pulses measured against the threshold is a straight line, in the case of pure {beta}-emitters. We then derive a simple relation between the data of this straight line and the maximal energy of the {beta}-spectrum of the radionuclide under consideration. (authors) [French] Description d'une methode simple d'analyse radioactive, permettant de determiner avec precision l'energie maximum des emetteurs-{beta}, ainsi que de deceler et de doser les impuretes radioactives dans un radionuclide. La technique decrite utilise un scintillateur plastique. On exploite le fait que la courbe du nombre d'impulsions mesurees, en fonction du seuil de discrimination, est une droite, pour un emetteur-{beta} pur. Une relation simple entre les caracteristiques de cette droite et l'energie maximum du spectre-{beta} du radionuclide, correspondant, a ete etablie. (auteurs)

  5. Beta delayed particle emission in light nuclei

    International Nuclear Information System (INIS)

    Riisager, K.; Gabelmann, H.

    1991-01-01

    A short discussion of theoretical treatments of beta delayed particle emission is followed by a presentation of data on the newly found beta delayed deuteron decay of 6 He. This decay cannot be described properly with existing theories. (author) 8 refs.; 3 figs

  6. Beta-decay study of T{sub z}=-2 proton-rich nucleus {sup 24}Si

    Energy Technology Data Exchange (ETDEWEB)

    Ichikawa, Y.; Iwasaki, H.; Nakao, T.; Ong, H.J.; Onishi, T.K.; Suzuki, D.; Suzuki, H.; Suzuki, M.K. [University of Tokyo, Department of Physics, Tokyo (Japan); Kubo, T.; Aoi, N.; Fukuda, N.; Motobayashi, T.; Yamada, K.N.; Sakurai, H. [RIKEN, RIKEN Nishina Center, Saitama (Japan); Banerjee, V.; Chakrabarti, A. [Variable Energy Cyclotron Centre, Kolkata (India); Kubono, S.; Yamaguchi, H. [University of Tokyo, Center for Nuclear Study, Tokyo (Japan); Nakabayashi, T.; Nakamura, T.; Okumura, T. [Tokyo Institute of Technology, Department of Physics, Tokyo (Japan); Teranishi, T. [Kyushu University, Department of Physics, Fukuoka (Japan)

    2009-12-15

    {beta} -decay spectroscopy on a T{sub z}=-2 proton-rich nucleus {sup 24}Si was performed. The decay scheme of {sup 24}Si was reconstructed by the {beta} -delayed {gamma} -ray and proton measurements. Two {beta} branches to the bound 1{sub 1}{sup +} and 1{sub 2}{sup +} states in {sup 24}Al were observed for the first time. The observation of the allowed transition firmly established the spin-parity assignment for the 1{sub 2}{sup +} states. The branching ratios to the 1{sub 1}{sup +} and 1{sub 2}{sup +} states were determined to be 31(4)% and 23.9(15)%, respectively. The branching ratios to three unbound states in {sup 24}Al including a new level at 6.735MeV were also determined for the first time. The level structure of {sup 24}Al was compared with its mirror nucleus {sup 24}Na. The Thomas-Ehrman shift on the 1{sub 2}{sup +} state indicates s -wave dominance in the state as well as a characteristic behavior of the weakly bound s-wave proton in {sup 24}Al. (orig.)

  7. Monitoring tritium in air containing other beta-emitters using ion chambers

    International Nuclear Information System (INIS)

    Jalbert, R.A.

    1975-01-01

    A flow-through ionization chamber instrument is described which is capable of measuring tritium in air containing high concentrations of other beta emitters. The instrument employs a separate concentric chamber with a thin common wall opaque only to tritium betas. Currents produced in the two chambers are subtracted leaving only the current due to tritium. With a 1.6-l sampling chamber and an 18-s time constant, tritium concentrations of 10 -6 μCi/ml to 10 -4 μCi/ml are measured with 2 sigma confidence in background beta concentrations of 4 x 10 -5 μCi/ml to 0.4 muCi/ml, respectively. (auth)

  8. Discriminator setting and cocktail preparation for analysis of alpha and beta emitters in aqueous solution using liquid scintillation counter

    International Nuclear Information System (INIS)

    Zaini Hamzah; Masitah Alias; Zaharudin Ahmad

    2011-01-01

    Liquid scintillation counting (LSC) is not only being used to measure pure beta emitters, but it can be used to measure both alpha and beta emitters simultaneously. Measurement of alpha and beta emitters in aqueous solution is done using a single sample. For the sample preparation, colorless detergent or emulsifier was used to incorporate the water into an organic based scintillator to produce a clear homogeneous solution, since this is the best form to give the highest count rate and detection efficiency. The instrument also need some attention, where after calibration, the LSC was set for the discriminator level which is suitable for measurement of both alpha and beta radiations. In this study, the focus is on the development of the best scintillation cocktail and establishes the best discriminator setting. From this study the best proportion of scintillation cocktail is 2:4:4 for water, toluene, and Triton-N101 (emulsifier) respectively and the best discriminator setting for alpha and beta counting are 120. (author)

  9. Investigating proton emitters at the limits of stability with radioactive beams from the Oak Ridge facility

    Energy Technology Data Exchange (ETDEWEB)

    Toth, K.S. [Oak Ridge National Lab., TN (United States); Batchelder, J.C.; Zganjar, E.F. [Louisiana State Univ., Baton Rouge, LA (United States); Bingham, C.R.; Wauters, J. [Tennessee Univ., Knoxville, TN (United States); Davinson, T.; MacKenzie, J.A.; Woods, P.J. [Edinburgh Univ. (United Kingdom)

    1996-10-01

    By using beams from the Holifield Radioactive Ion Beam Facility at ORNL, it should be possible to identify many new ground-state proton emitters in the mass region from Sn to Pb. In these investigations nuclei produced in fusion-evaporation reactions will be separated from incident ions and dispersed in mass/charge with a recoil mass separator and then implanted into a double-sided Si strip detector for study of proton (and {alpha}-particle) radioactivity. This paper summarizes data presently extant on proton emitters and then focuses on tests and initial experiments that will be carried out with stable beams and with radioactive ions as they are developed at the Oak Ridge facility.

  10. International Standardization of Pure Beta Emitters

    International Nuclear Information System (INIS)

    Los Arcos, Jose Maria; Rodriguez, Leonor

    2006-01-01

    The paper describes the traditional methods of standardization of Pure Beta Emitters, their principal characteristics, advantage and drawbacks. It does comparisons between two metrological LSC methods: Triple to double coincidence ratio (TDCR) method and the CIEMAT/NIST method and presents the result obtained with several Key Comparisons serving as practical test of both methods. Both of them represent the siferrit of methods of standardization of pure (and mixed decay) radionuclides. ESIR WG of CCRI(II) is to implement a reference exchange system for the permanent equivalence of β, α and electron capture nuclides, similar to traditional SIR gamma. ESIR project is currently testing a new XAN scintillator and operational tests of the whole system at BIPM are expected by the end of 2006 (test restricted to ESIR NMI members)

  11. Hyperfine interactions of {beta}-emitter {sup 12}N in TiO{sub 2}

    Energy Technology Data Exchange (ETDEWEB)

    Maruyama, Yukiko [Osaka Univ., Toyonaka (Japan). Faculty of Science; Izumikawa, Takuji; Tanigaki, Minoru [and others

    1997-03-01

    Hyperfine interactions of {beta}-emitter {sup 12}N (I{sup {pi}} = 1{sup -}, T{sub 1/2} 11ms) in TiO{sub 2} has been studied. A {beta}-NMR spectrum on the polarized {sup 12}N implanted in TiO{sub 2} shows that {sup 12}N are located at two different sites and maintain about 100% of initial polarization. These are the first phenomena observed in ionic crystals. (author)

  12. Beta-delayed neutron decay of $^{33}$Na

    CERN Document Server

    Radivojevic, Z; Caurier, E; Cederkäll, J; Courtin, S; Dessagne, P; Jokinen, A; Knipper, A; Le Scornet, G; Lyapin, V G; Miehé, C; Nowacki, F; Nummela, S; Oinonen, M; Poirier, E; Ramdhane, M; Trzaska, W H; Walter, G; Äystö, J

    2002-01-01

    Beta-delayed neutron decay of /sup 33/Na has been studied using the on-line mass separator ISOLDE. The delayed neutron spectra were measured by time-of-flight technique using fast scintillators. Two main neutron groups at 800(60) and 1020(80) keV were assigned to the /sup 33/Na decay, showing evidence for strong feeding of states at about 4 MeV in /sup 33/Mg. By simultaneous beta - gamma -n counting the delayed neutron emission probabilities P/sub 1n/ = 47(6)% and P /sub 2n/ = 13(3)% were determined. The half-life value for /sup 33 /Na, T/sub 1/2/ = 8.0(3) ms, was measured by three different techniques, one employing identifying gamma transitions and two employing beta and neutron counting. (21 refs).

  13. Proton microprobe analysis of pancreatic. beta. cells

    Energy Technology Data Exchange (ETDEWEB)

    Lindh, U [Uppsala Univ. (Sweden). Gustaf Werner Inst.; Juntti-Berggren, L; Berggren, P O; Hellman, B [Uppsala Univ. (Sweden)

    1985-01-01

    Freeze-dried pancreas sections from obese hyperglycemic mice were subjected to proton bombardment and the elemental contents in the ..beta.. cells and the exocrine part were obtained from the characteristic X-rays emitted. Quantitative data were provided for 18 different elements. The mole ratio between K and Na exceeded 10, implying that neither the sample preparation nor the irradiation had induced significant diffuse changes. With the demonstration of this high K/Na ratio it seems likely that also the ..beta.. cells are equipped with an efficient Na/sup +//K/sup +/ pump. The ..beta.. cells contained about 70 mmoles Cl per litre cell water. Observed amounts of Ca and Mg were equivalent to those previously recorded by electrothermal atomic absorption spectroscopy. The significant role of Zn for the storage of insulin was emphasized by the demonstration of 3 times as much of this element in the ..beta.. cells as compared with the exocrine pancreas. In addition, the sensitivity of the proton microprobe enabled measurements of various trace elements such as Rb, Cr, Cu, Al and Pb not previously demonstrated in the pancreatic ..beta.. cells.

  14. Beta decay of Cu-56

    NARCIS (Netherlands)

    Borcea, R; Aysto, J; Caurier, E; Dendooven, P; Doring, J; Gierlik, M; Gorska, M; Grawe, H; Hellstrom, M; Janas, Z; Jokinen, A; Karny, M; Kirchner, R; La Commara, M; Langanke, K; Martinez-Pinedo, G; Mayet, P; Nieminen, A; Nowacki, F; Penttila, H; Plochocki, A; Rejmund, M; Roeckl, E; Schlegel, C; Schmidt, K; Schwengner, R; Sawicka, M

    2001-01-01

    The proton-rich isotope Cu-56 was produced at the GSI On-Line Mass Separator by means of the Si-28(S-32, p3n) fusion-evaporation reaction. Its beta -decay properties were studied by detecting beta -delayed gamma rays and protons. A half-Life of 93 +/- 3 ms was determined for Cu-56. Compared to the

  15. Measurement of the internal bremsstrahlung spectrum of a 89Sr beta emitter in the 1–100 keV photon energy regime

    International Nuclear Information System (INIS)

    Singh, Amrit; Dhaliwal, A.S.

    2015-01-01

    The internal bremsstrahlung (IB) spectrum of 89 Sr, which is a unique first forbidden beta emitter, is studied in the 1–100 keV photon energy regime. The IB spectrum is experimentally measured using a Si(Li) detector, which is efficient in this photon energy regime, and is compared with the IB distributions that are predicted by the Knipp, Uhlenbeck and Bloch (KUB), Nilsson, and Lewis and Ford theories. In the soft energy regime up to 15 keV, the measured results are in agreement with all the aforementioned theories. However, from 16–30 keV, the experimental results are in agreement with the Lewis and Ford theory, which applies to forbidden transitions, and at higher photon energies, the Nilsson theory best describes the measured results. The differences among the different theories also increase with the photon energy. The effect of the electrostatic Coulomb field on the IB process for beta emitters with different end-point energies is investigated by comparing the ratio of the IB probabilities predicted using the KUB and Nilsson theories for 35 S and 89 Sr, i.e., soft and hard beta emitters, respectively. The Coulomb effect is shown to be significant in the high photon energy regime and for beta emitters with low end-point energies. - Highlights: • Internal bremsstrahlung spectrum of 89 Sr, a unique first forbidden beta emitter, is studied. • The measurements are taken in the photon energy regions of 1–100 keV with Si(Li) detector. • The measured results are deviating from Lewis and Ford theory and are close to the Nilsson theory. • The effect of Coulomb field on the IB process for different end point energy sources is investigated. • Effect of Coulomb field is more for low energy beta emitter towards the high energy end

  16. {beta}-Delayed proton-decay study of {sup 20}Mg and its implications for the {sup 19}Ne(p,{gamma}){sup 20}Na breakout reaction in X-ray bursts

    Energy Technology Data Exchange (ETDEWEB)

    Wallace, J.P., E-mail: J.P.Wallace@sms.ed.ac.uk [University of Edinburgh, Edinburgh, EH9 3JZ (United Kingdom); Woods, P.J.; Lotay, G. [University of Edinburgh, Edinburgh, EH9 3JZ (United Kingdom); Alharbi, A.; Banu, A. [Cyclotron Institute, Texas A and M University, College Station, TX (United States); David, H.M.; Davinson, T. [University of Edinburgh, Edinburgh, EH9 3JZ (United Kingdom); McCleskey, M.; Roeder, B.T.; Simmons, E.; Spiridon, A.; Trache, L.; Tribble, R.E. [Cyclotron Institute, Texas A and M University, College Station, TX (United States)

    2012-05-30

    Under astrophysical conditions of high temperature and density, such as for example found in X-ray bursts, breakout can occur from the hot CNO cycles into the rapid proton capture process. A key breakout route is via the sequence {sup 15}O({alpha},{gamma}){sup 19}Ne(p,{gamma}){sup 20}Na. The {sup 19}Ne(p,{gamma}){sup 20}Na reaction rate is expected to be dominated by a single resonance at 457(3) keV. The identity of the resonance has been under discussion for a long time, with J{sup {pi}}=1{sup +} and 3{sup +} assignments suggested. In this study of the {beta}-delayed proton decay of {sup 20}Mg we report a new, significantly more stringent, upper limit on the {beta}-decay branch to this state of 0.02% with a confidence level of 90%. This makes a 1{sup +} assignment highly unlikely and favours a 3{sup +} assignment for which no branch is expected to be observed. The 3{sup +} state is predicted to have a significantly higher resonance strength, and to produce a proportionately higher {sup 19}Ne(p,{gamma}){sup 20}Na reaction rate in X-ray burst conditions.

  17. Emittance preservation

    Energy Technology Data Exchange (ETDEWEB)

    Kain, V; Arduini, G; Goddard, B; Holzer, B J; Jowett, J M; Meddahi, M; Mertens, T; Roncarolo, F; Schaumann, M; Versteegen, R; Wenninger, J [European Organization for Nuclear Research, Geneva (Switzerland)

    2012-07-01

    Emittance measurements during the LHC proton run 2011 indicated a blow-up of 20 % to 30 % from LHC injection to collisions. This presentation will show the emittance preservation throughout the different parts of the LHC cycle and discuss the current limitations on emittance determination. An overview of emittance preservation through the injector complex as function of bunch intensity will also be given. Possible sources for the observed blow-up and required tests in 2012 will be presented. Possible improvements of emittance diagnostics and analysis tools for 2012 will be shown.

  18. New neutron-deficient isotopes of barium and rare-earth elements

    CERN Document Server

    Bogdanov, D D; Karnaukhov, V A; Petrov, L A; Plochocki, A; Subbotin, V G; Voboril, J

    1976-01-01

    The authors present an investigation of the short-lived neutron- deficient isotopes of barium and rare-earth elements. By using the BEMS-2 isotope separator on a heavy ion beam, 19 new isotopes were produced with mass numbers ranging from 117 to 138. Five of these (/sup 117/Ba, /sup 129,131/Nd and /sup 133,135/Sm) turned out to be delayed proton emitters. The beta -decay probabilities for the new isotopes have been analyzed in terms of the beta -strength function. An analysis of the proton spectrum shape has been performed using the statistical model for delayed proton emission.

  19. Delayed protons and properties of proton-rich nuclei

    International Nuclear Information System (INIS)

    Karnaukhov, V.A.

    1976-01-01

    The object of the investigation is to study the properties of proton-rich nuclei. The emphasis in the proposed survey is made on investigations in the range of Z > 50. Measurement of the total energy in emission of delayed protons (DP) enables one to determine the difference between the masses of initial and final isotopes. The statistical model of the DP emission is used for describing the proton spectrum. A comparison of the DP experimental and theoretical spectra shows that the presence of local resonances in the strength functions of the β dacay is rather a rule than an exception. Studies into the fine structure of the proton spectra supply information of the density of nuclei considerably removed from the β-stability line at the excitation energies of 3-7 MeV. The aproaches for retrieval of nuclear information with the aid of proton radiators developed so far can serve as a good basis for systematic investigation over a wide range of A and Z

  20. $\\beta$-decay and $\\beta$-delayed Neutron Emission Measurements at GSI-FRS Beyond N=126, for r-process Nucleosynthesis

    CERN Document Server

    Caballero-Folch, R; Cortès, G; Taín, J L; Agramunt, J; Algora, A; Ameil, F; Ayyad, Y; Benlliure, J; Bowry, M; Calviño, F; Cano-Ott, D; Davinson, T; Dillmann, I; Estrade, A; Evdokimov, A; Faestermann, T; Farinon, F; Galaviz, D; García-Ríos, A; Geissel, H; Gelletly, W; Gernhäuser, R; Gómez-Hornillos, M B; Guerrero, C; Heil, M; Hinke, C; Knöbel, R; Kojouharov, I; Kurcewicz, J; Kurz, N; Litvinov, Y; Maier, L; Marganiec, J; Marta, M; Martínez, T; Montes, F; Mukha, I; Napoli, D R; Nociforo, C; Paradela, C; Pietri, S; Podolyák, Zs; Prochazka, A; Rice, S; Riego, A; Rubio, B; Schaffner, H; Scheidenberger, C; Smith, K; Sokol, E; Steiger, K; Sun, B; Takechi, M; Testov, D; Weick, H; Wilson, E; Winfield, J S; Wood, R; Woods, P J; Yeremin, A

    2014-01-01

    New measurements of very exotic nuclei in the neutron-rich region beyond N=126 have been performed at the GSI facility with the fragment separator (FRS). The aim of the experiment is to determine half-lives and beta-delayed neutron emission branching ratios of isotopes of Hg, Tl and Pb in this region. This contribution summarizes final counting statistics for identification and for implantation, as well as the present status of the data analysis of the half-lives. In summary, isotopes of Pt, Au, Hg, Ti, Pb, Bi, Po, At, Rn and Fr were clearly identified and several of them (Hg208-211, Tl211-215, Pb214-218) were implanted with enough statistics to determine their half-lives. About half of them are expected to be neutron emitters, in such cases it will become possible to obtain the neutron emission probabilities, P-n.

  1. An analytical model to calculate absorbed fractions for internal dosimetry with alpha, beta and gamma emitters

    Directory of Open Access Journals (Sweden)

    Ernesto Amato

    2014-03-01

    Full Text Available We developed a general model for the calculation of absorbed fractions in ellipsoidal volumes of soft tissue uniformly filled with alpha, beta and gamma emitting radionuclides. The approach exploited Monte Carlo simulations with the Geant4 code to determine absorbed fractions in ellipsoids characterized by a wide range of dimensions and ellipticities, for monoenergetic emissions of each radiation type. The so-obtained absorbed fractions were put in an analytical relationship with the 'generalized radius', calculated as 3V/S, where V is the ellipsoid volume and S its surface. Radiation-specific parametric functions were obtained in order to calculate the absorbed fraction of a given radiation in a generic ellipsoidal volume. The dose from a generic radionuclide can be calculated through a process of summation and integration over the whole radionuclide emission spectrum, profitably implemented in an electronic spreadsheet. We compared the results of our analytical calculation approach with those obtained from the OLINDA/EXM computer software, finding a good agreement in a wide range of sphere radii, for the high-energy pure beta emitter 90Y, the commonly employed beta-gamma emitter 131I, and the pure alpha emitter 213Po. The generality of our approach makes it useful an easy to implement in clinical dosimetry calculations as well as in radiation safety estimations when doses from internal radionuclide uptake are to be taken into account.

  2. Beta-decay rate and beta-delayed neutron emission probability of improved gross theory

    Science.gov (United States)

    Koura, Hiroyuki

    2014-09-01

    A theoretical study has been carried out on beta-decay rate and beta-delayed neutron emission probability. The gross theory of the beta decay is based on an idea of the sum rule of the beta-decay strength function, and has succeeded in describing beta-decay half-lives of nuclei overall nuclear mass region. The gross theory includes not only the allowed transition as the Fermi and the Gamow-Teller, but also the first-forbidden transition. In this work, some improvements are introduced as the nuclear shell correction on nuclear level densities and the nuclear deformation for nuclear strength functions, those effects were not included in the original gross theory. The shell energy and the nuclear deformation for unmeasured nuclei are adopted from the KTUY nuclear mass formula, which is based on the spherical-basis method. Considering the properties of the integrated Fermi function, we can roughly categorized energy region of excited-state of a daughter nucleus into three regions: a highly-excited energy region, which fully affect a delayed neutron probability, a middle energy region, which is estimated to contribute the decay heat, and a region neighboring the ground-state, which determines the beta-decay rate. Some results will be given in the presentation. A theoretical study has been carried out on beta-decay rate and beta-delayed neutron emission probability. The gross theory of the beta decay is based on an idea of the sum rule of the beta-decay strength function, and has succeeded in describing beta-decay half-lives of nuclei overall nuclear mass region. The gross theory includes not only the allowed transition as the Fermi and the Gamow-Teller, but also the first-forbidden transition. In this work, some improvements are introduced as the nuclear shell correction on nuclear level densities and the nuclear deformation for nuclear strength functions, those effects were not included in the original gross theory. The shell energy and the nuclear deformation for

  3. Prediction and design of efficient exciplex emitters for high-efficiency, thermally activated delayed-fluorescence organic light-emitting diodes.

    Science.gov (United States)

    Liu, Xiao-Ke; Chen, Zhan; Zheng, Cai-Jun; Liu, Chuan-Lin; Lee, Chun-Sing; Li, Fan; Ou, Xue-Mei; Zhang, Xiao-Hong

    2015-04-08

    High-efficiency, thermally activated delayed-fluorescence organic light-emitting diodes based on exciplex emitters are demonstrated. The best device, based on a TAPC:DPTPCz emitter, shows a high external quantum efficiency of 15.4%. Strategies for predicting and designing efficient exciplex emitters are also provided. This approach allow prediction and design of efficient exciplex emitters for achieving high-efficiency organic light-emitting diodes, for future use in displays and lighting applications. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Proton decay: spectroscopic probe beyond the proton drip line

    International Nuclear Information System (INIS)

    Seweryniak, D; Davids, C N; Robinson, A; Woods, P J; Blank, B; Carpenter, M P; Davinson, T; Freeman, S J; Hammond, N; Hoteling, N; Janssens, R V F; Khoo, T L; Liu, Z; Mukherjee, G; Shergur, J; Sinha, S; Sonzogni, A A; Walters, W B; Woehr, A

    2005-01-01

    Proton decay has been transformed in recent years from an exotic phenomenon into a powerful spectroscopic tool. The frontiers of experimental and theoretical proton-decay studies will be reviewed. Different aspects of proton decay will be illustrated with recent results on the deformed proton emitter 135 Tb, the odd-odd deformed proton emitter 130 Eu, the complex fine structure in the odd-odd 146 Tm nucleus and on excited states in the transitional proton emitter 145 Tm

  5. Kinematic shifts of beta -delayed particles as a probe of beta - nu angular correlations

    CERN Document Server

    Clifford, E T H; Evans, H C; Fästermann, T; Hagberg, E; Hardy, J C; Jackson, K P; Koslowsky, V T; Schmeing, H; Schrewe, U J

    1981-01-01

    Beta-delayed particles undergo a kinematic shift in energy due to recoil motion of the daughter nucleus following beta decay. A careful measurement of this energy shift can be used to establish the ratio of vector to axial vector components in beta transitions. Alpha-beta coincidence data for the beta-delayed alpha decay of /sup 20/Na have been obtained. Component ratios for 6 transitions including the superallowed branch are found. Limits on charge dependent mixing with the analogue state are deduced for 5 states in /sup 20/Ne*. For the superallowed branch the axial vector component is found; the polar vector component is deduced and establishes a value for the vector weak coupling constant of G/sub V/=(1.355+or-0.036)*10/sup -49/ erg cm /sup 3/. (13 refs).

  6. Studies and calculations of transverse emittance growth in high-energy proton storage rings

    International Nuclear Information System (INIS)

    Mane, S.R.; Jackson, G.

    1989-03-01

    In the operation of proton-antiproton colliders, an important goal is to maximize the integrated luminosity. During such operations in the Fermilab Tevatron, the transverse beam emittances were observed to grow unexpectedly quickly, thus causing a serious reduction of the luminosity. We have studied this phenomenon experimentally and theoretically. A formula for the emittance growth rate, due to random dipole kicks, is derived. In the experiment, RF phase noise of known amplitude was deliberately injected into the Tevatron to kick the beam randomly, via dispersion at the RF cavities. Theory and experiment are found to agree reasonably well. We also briefly discuss the problem of quadrupole kicks. 14 refs., 2 figs., 3 tabs

  7. Spectroscopy of proton-rich nuclei in the rare earth region

    International Nuclear Information System (INIS)

    Toth, K.S.; Nitschke, J.M.; Vierinen, K.S.; Wilmarth, P.A.; Firestone, R.B.; Kortelahti, M.O.

    1990-01-01

    The isotope separator facility OASIS, on-line at the Lawrence Berkeley Laboratory SuperHILAC, was used to investigate proton-rich rare earth nuclei. Single-particle states near the 82-neutron shell were delineated, numerous new isotopes, isomers, and β-delayed proton emitters were discovered and the α-decay properties of some nuclides with N > 84 were reexamined. In this contribution the experimental program is summarized briefly, the excitation energies of the s 1/2 and h 11/2 proton states in this mass region are discussed, and results on the β-delayed-proton spectra of 145 Dy and 147 Er are presented. 17 refs., 5 figs

  8. Procedure to carry out leakage test in beta radiation sealed sources emitters of 90Sr/90Y

    International Nuclear Information System (INIS)

    Alvarez R, J. T.

    2010-09-01

    In the alpha-beta room of the Secondary Laboratory of Dosimetric Calibration of the Metrology Department of Ionizing Radiations ophthalmic applicators are calibrated in absorbed dose terms in water D w ; these applicators, basically are emitter sealed sources of pure beta radiation of 90 Sr / 90 Y. Concretely, the laboratory quality system indicates to use the established procedure for the calibration of these sources, which establishes the requirement of to carry out a leakage test, before to calibrate the source. However, in the Laboratory leakage test certificates sent by specialized companies in radiological protection services have been received, in which are used gamma spectrometry equipment s for beta radiation leakage tests, since it is not reliable to detect pure beta radiation with a scintillating detector with NaI crystal, (because it could detect the braking radiation produced in the detector). Therefore the Laboratory has had to verify the results of the tests with a correct technique, with the purpose of determining the presence of sources with their altered integrity and radioactive material leakage. The objective of this work is to describe a technique for beta activity measurement - of the standard ISO 7503, part 1 (1988) - and its application with a detector Gm plane (type pankage) in the realization of leakage tests in emitter sources of pure beta radiation, inside the mark of quality assurance indicated by the report ICRU 76. (Author)

  9. The delayed proton emission in the A≃65-77 mass region, statistical aspects and structure effects

    CERN Document Server

    Giovinazzo, J; Miehé, C

    2000-01-01

    In the decay of the series of T sub Z =1/2 nuclei, sup 6 sup 5 Ge, sup 6 sup 9 Se, sup 7 sup 3 Kr and sup 7 sup 7 Sr, a statistical analysis was applied to the beta delayed proton emission to obtain nuclear structure information. New results emerge from this study, in the light of improvements in the experimental techniques and developments of the analysis method. Experimental results are analysed by comparison with a statistical model, in order to extract information on level densities and partial transition widths of the proton emitting nuclei. Limitations of the existing descriptions of processes for nuclei far from stability are pointed out.

  10. Beta-delayed proton and alpha emission from 36K

    International Nuclear Information System (INIS)

    Ewan, G.T.; Hagberg, E.; Hardy, J.C.; Jonson, B.; Mattsson, S.; Tidemand-Petersson, P.

    1980-01-01

    Protons and α-particles emitted from levels in 36 Ar following the β-decay of 36 K have been measured. Proton transitions were found from levels at 9217, 9493 and 9870 keV in 36 Ar and α-transitions from levels at 8860, 8890, 9680 and 10548 keV. Seven previously unreported β-transitions to highly excited states in 36 Ar have been identified. The assignments of spins and parities to the particle emitting levels are discussed. (orig.)

  11. Emittance growth induced by electron cloud in proton storage rings

    CERN Document Server

    Benedetto, Elena; Coppa, G

    2006-01-01

    In proton and positron storage rings with many closely spaced bunches, a large number of electrons can accumulate in the beam pipe due to various mechanisms (photoemission, residual gas ionization, beam-induced multipacting). The so-formed electron cloud interacts with the positively charged bunches, giving rise to instabilities, emittance growth and losses. This phenomenon has been observed in several existing machines such as the CERN Super Proton Synchrotron (SPS), whose operation has been constrained by the electron-cloud problem, and it is a concern for the Large Hadron Collider (LHC), under construction at CERN. The interaction between the beam and the electron cloud has features which cannot be fully taken into account by the conventional and known theories from accelerators and plasma physics. Computer simulations are indispensable for a proper prediction and understanding of the instability dynamics. The main feature which renders the beam-cloud interactions so peculiar is that the the electron cloud...

  12. Nuclei far from the beta stability line. High-energy beta decay and delayed-particle emission

    International Nuclear Information System (INIS)

    Hansen, R.G.; Hornshj, P.

    1976-01-01

    Progress in on-line mass separation together with improved proton accelerators now permit the production of secondary ion-beams of the order of 10 11 atoms per second. Applications to the study of delayed-proton and delayed-alpha emission are discussed. These effects have been used for the estimation of alpha-emission strength functions at 4-6 MeV excitation energy, and for the determination of level densities through fluctuation analysis

  13. Analysis of low energy beta-emitters

    International Nuclear Information System (INIS)

    Murphy, D.L.

    1979-10-01

    A survey was made of the instruments used for the determination of low energy beta radioactivity. Techniques commonly used are gas flow proportional counting, liquid scintillation counting, solid scintillation counting, and internal ionization chamber counting, solid state detector counting, and radiochemical separation followed by counting using one of the preceeding techniques. The first four techniques were examined and compared with each other. The sensitivities of the techniques were compared on the basis of the detection limits quoted for instruments described in the technical and reviewed literature. The detection limits were then related to the occupational and public individual maximum levels for air and water. Attention is focused primarily on the continuous monitoring of air for 3 H and 85 Kr, a medium energy β-emitter. It is clear that several continuous air monitoring instruments are readily available for measuring low energy β concentrations, even in presence of certain other activity, at occupational levels. However, these instruments do not typically have sensitivities comparable to the public individual levels. Moreover, their capabilities for giving results in real time and for differentiating among the radionuclides actually present is limited

  14. Methodology to determine the efficiency of a beta emitter gases monitor; Metodologia para determinacao da eficiencia de um monitor de gases emissores de particulas beta

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, Marcos Rodrigues de

    1995-07-01

    This work presents a methodology developed to determinate the efficiency of air monitors used to measure the concentration of beta emitters noble gases in nuclear power stations. Efficiency values, obtained by means of theoretical computation are compared with experimental values. The experimental part of the work was performed using three different point beta source, to simulate small amounts of gas uniformly distributed in small volume. The comparison shows that theoretical an experimental values agree within 4,2 % for {sup 90}Sr + {sup 90}Y, {sup 204}Tl and {sup 45}Ca beta sources. (author)

  15. Recent activities for β-decay half-lives and β-delayed neutron emission of very neutron-rich isotopes

    Energy Technology Data Exchange (ETDEWEB)

    Dillmann, Iris [TRIUMF, Vancouver BC, V6T 2A3, Canada and GSI Helmholtzzentrum für Schwerionenforschung GmbH, D-64291 Darmstadt (Germany); Abriola, Daniel [Laboratorio Tandar, Comisión Nacional de Energía Atómica, B1650KINA, San Martín, Buenos Aires (Argentina); Singh, Balraj [Department of Physics and Astronomy, McMaster University, Hamilton ON, L8S 4M1 (Canada)

    2014-05-02

    Beta-delayed neutron (βn) emitters play an important, two-fold role in the stellar nucleosynthesis of heavy elements in the 'rapid neutron-capture process' (r process). On one hand they lead to a detour of the material β-decaying back to stability. On the other hand, the released neutrons increase the neutron-to-seed ratio, and are re-captured during the freeze-out phase and thus influence the final solar r-abundance curve. A large fraction of the isotopes inside the r-process reaction path are not yet experimentally accessible and are located in the (experimental) 'Terra Incognita'. With the next generation of fragmentation and ISOL facilities presently being built or already in operation, one of the main motivation of all projects is the investigation of these very neutron-rich isotopes. A short overview of one of the planned programs to measure βn-emitters at the limits of the presently know isotopes, the BRIKEN campaign (Beta delayed neutron emission measurements at RIKEN) will be given. Presently, about 600 β-delayed one-neutron emitters are accessible, but only for a third of them experimental data are available. Reaching more neutron-rich isotopes means also that multiple neutron-emission becomes the dominant decay mechanism. About 460 β-delayed two-, three-or four-neutron emitters are identified up to now but for only 30 of them experimental data about the neutron branching ratios are available, most of them in the light mass region below A=30. The International Atomic and Energy Agency (IAEA) has identified the urgency and picked up this topic recently in a 'Coordinated Research Project' on a 'Reference Database for Beta-Delayed Neutron Emission Data'. This project will review, compile, and evaluate the existing data for neutron-branching ratios and half-lives of β-delayed neutron emitters and help to ensure a reliable database for the future discoveries of new isotopes and help to constrain astrophysical and

  16. Highly efficient electroluminescence from a solution-processable thermally activated delayed fluorescence emitter

    Energy Technology Data Exchange (ETDEWEB)

    Wada, Yoshimasa; Kubo, Shosei; Suzuki, Katsuaki; Kaji, Hironori, E-mail: kaji@scl.kyoto-u.ac.jp [Institute for Chemical Research, Kyoto University, Uji, Kyoto 611-0011 (Japan); Shizu, Katsuyuki [Institute for Chemical Research, Kyoto University, Uji, Kyoto 611-0011 (Japan); Center for Organic Photonics and Electronics Research (OPERA), Kyushu University, 744 Motooka, Nishi, Fukuoka 819-0395 (Japan); Tanaka, Hiroyuki [Center for Organic Photonics and Electronics Research (OPERA), Kyushu University, 744 Motooka, Nishi, Fukuoka 819-0395 (Japan); Adachi, Chihaya [Center for Organic Photonics and Electronics Research (OPERA), Kyushu University, 744 Motooka, Nishi, Fukuoka 819-0395 (Japan); Japan Science and Technology Agency (JST), ERATO, Adachi Molecular Exciton Engineering Project, 744 Motooka, Nishi, Fukuoka 819-0395 (Japan)

    2015-11-02

    We developed a thermally activated delayed fluorescence (TADF) emitter, 2,4,6-tris(4-(9,9-dimethylacridan-10-yl)phenyl)-1,3,5-triazine (3ACR-TRZ), suitable for use in solution-processed organic light-emitting diodes (OLEDs). When doped into 4,4′-bis(carbazol-9-yl)biphenyl (CBP) host at 16 wt. %, 3ACR-TRZ showed a high photoluminescence quantum yield of 98%. Transient photoluminescence decay measurements of the 16 wt. % 3ACR-TRZ:CBP film confirmed that 3ACR-TRZ exhibits efficient TADF with a triplet-to-light conversion efficiency of 96%. This high conversion efficiency makes 3ACR-TRZ attractive as an emitting dopant in OLEDs. Using 3ACR-TRZ as an emitter, we fabricated a solution-processed OLED exhibiting a maximum external quantum efficiency of 18.6%.

  17. A New Design Strategy for Efficient Thermally Activated Delayed Fluorescence Organic Emitters: From Twisted to Planar Structures

    KAUST Repository

    Chen, Xiankai

    2017-10-17

    In the traditional molecular design of thermally activated delayed fluorescence (TADF) emitters composed of electron-donor and electron-acceptor moieties, achieving a small singlet-triplet energy gap (ΔEST ) in strongly twisted structures usually translates into a small fluorescence oscillator strength, which can significantly decrease the emission quantum yield and limit efficiency in organic light-emitting diode devices. Here, based on the results of quantum-chemical calculations on TADF emitters composed of carbazole donor and 2,4,6-triphenyl-1,3,5-triazine acceptor moieties, a new strategy is proposed for the molecular design of efficient TADF emitters that combine a small ΔEST with a large fluorescence oscillator strength. Since this strategy goes beyond the traditional framework of structurally twisted, charge-transfer type emitters, importantly, it opens the way for coplanar molecules to be efficient TADF emitters. Here, a new emitter, composed of azatriangulene and diphenyltriazine moieties, is theoretically designed, which is coplanar due to intramolecular H-bonding interactions. The synthesis of this hexamethylazatriangulene-triazine (HMAT-TRZ) emitter and its preliminary photophysical characterizations point to HMAT-TRZ as a potential efficient TADF emitter.

  18. New β-delayed proton lines from 23Al

    DEFF Research Database (Denmark)

    Kirsebom, Oliver Sølund; Fynbo, H.; Jokinen, A.

    2011-01-01

    We report on a new measurement of the β -delayed proton spectrum of 23 Al. Higher statistics compared to previous measurements allow us to identify new proton lines in the energy range 1--2 MeV. A statistical analysis of the observed β strength shows that the B (GT) values are fully consistent...

  19. A possible island of beta-delayed neutron precursors in heavy nucleus region

    International Nuclear Information System (INIS)

    Zhang Li

    1991-01-01

    The possible Beta-Delayed neutron precursors in the elements Tl, Hg, and Au were predicted following a systematic research on the known Beta-Delayed neutron precursors. The masses of the unknown nuclei and neutron emission probabilities were calculated

  20. On the Proton Spectrum in Free Neutron beta-decay

    CERN Document Server

    Bunatian, G G

    2000-01-01

    We consider the calculations which are appropriate to acquire with a high precision, of ~1% or better, the general characteristics of weak interactions from the experiments on the free neutron beta-decay; the principle emphasis is placed on the phenomena associated with the recoil of protons. The part played by electromagnetic interactions in beta-decay is visualized, with special attention drawn to the influence of the gamma-radiation on the momentum distribution of the particles in the final state. The effect of electromagnetic interactions on the proton recoil spectrum is studied, in the light of the experiments which are carried out and planned for now. The results of the calculations, which are to be confronted with the experimental data, are presented upright in terms of the effective Lagrangian underlying the inquiry. Owing to electromagnetic interactions, the corrections to the energy distribution of protons prove to amount to the value of a few per cent. Nowadays, this is substantial to obtain with a...

  1. β-delayed proton decay of 28S

    International Nuclear Information System (INIS)

    Pougheon, F.; Borrel, V.; Jacmart, J.C.; Bazin, D.; Del Moral, R.; Dufour, J.P.; Hubert, F.; Pravikoff, M.S.; Brown, B.A.

    1989-01-01

    β-delayed proton radioactivity has been observed for the 28 S isotope (T x = -2), produced by projectile fragmentation of 85 MeV/u 36 Ar. The measured half-life of 28 S is 125 ± 10 ms. Energy spectra of β-delayed protons have been measured. The lowest T = 2 state in the daughter nucleus 28 P has been located at an excitation energy of 5900 ± 21 keV. A comparison of the experimental data to the quadratic form of the isobaric multiplet mass equation shows that the energies of the five T = 2 states of the A = 28 quintet are well represented by that relation. Shell-model predictions for the half-life, location and decay properties of the lowest T = 2 state of 28 P are in good agreement with experimental data

  2. Beta-delayed particle decay of 17Ne

    International Nuclear Information System (INIS)

    Morton, A.C.; Chow, J.C.; King, J.D.; Boyd, R.N.; Bateman, N.P.T.; Buchmann, L.; D'Auria, J.M.; Davinson, T.; Dombsky, M.; Galster, W.; Gete, E.; Giesen, U.; Iliadis, C.; Jackson, K.P.; Powell, J.; Roy, G.; Shotter, A.

    2002-01-01

    The β-delayed particle decay of 17 Ne has been studied via proton-γ coincidences, time-of-flight measurements and the ''ratio-cut technique'', allowing cleanly-separated proton and α-particle spectra to be obtained. A complete set of proton and α branching ratios for the decay of 14 excited states in 17 F to the ground and excited states of 16 O and 13 N has been determined and branching ratios for the β decay of 17 Ne to these states have been deduced. From the branching ratios, f A t values and reduced Gamow-Teller matrix elements were calculated; no indication of isospin mixing in the isobaric analog state in 17 F was observed. From the measurement of proton-γ angular correlations, combined with the selection rules for an allowed β decay, we obtain J π =((1)/(2)) - for states at 8.436 and 9.450 MeV and ((3)/(2)) - for the state at 10.030 MeV in 17 F. Probabilities for the β-delayed pα decay to 12 C through the tails of the subthreshold 7.117 and 6.917 MeV states in 16 O have been calculated and the feasibility of using such decays to provide information about the rates for the E1 and E2 components of the 12 C(α,γ) 16 O reaction is discussed

  3. Monte Carlo simulation of the spectral response of beta-particle emitters in LSC systems

    International Nuclear Information System (INIS)

    Ortiz, F.; Los Arcos, J.M.; Grau, A.; Rodriguez, L.

    1992-01-01

    This paper presents a new method to evaluate the counting efficiency and the effective spectra at the output of any dynodic stage, for any pure beta-particle emitter, measured in a liquid scintillation counting system with two photomultipliers working in sum-coincidence mode. The process is carried out by a Monte Carlo simulation procedure that gives the electron distribution, and consequently the counting efficiency, at any dynode, in response to the beta particles emitted, as a function of the figure of merit of the system and the dynodic gains. The spectral outputs for 3 H and 14 C have been computed and compared with experimental data obtained with two sets of quenched radioactive standards of these nuclides. (orig.)

  4. Beta Emission and Bremsstrahlung

    Energy Technology Data Exchange (ETDEWEB)

    Karpius, Peter Joseph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-11-13

    Bremsstrahlung is continuous radiation produced by beta particles decelerating in matter; different beta emitters have different endpoint energies; high-energy betas interacting with high-Z materials will more likely produce bremsstrahlung; depending on the data, sometimes all you can say is that a beta emitter is present.

  5. A New Design Strategy for Efficient Thermally Activated Delayed Fluorescence Organic Emitters: From Twisted to Planar Structures

    KAUST Repository

    Chen, Xiankai; Tsuchiya, Youichi; Ishikawa, Yuma; Zhong, Cheng; Adachi, Chihaya; Bredas, Jean-Luc

    2017-01-01

    In the traditional molecular design of thermally activated delayed fluorescence (TADF) emitters composed of electron-donor and electron-acceptor moieties, achieving a small singlet-triplet energy gap (ΔEST ) in strongly twisted structures usually

  6. Prospects for future proton studies at HRIBF

    International Nuclear Information System (INIS)

    Bingham, C.R.; Batchelder, J. C.; Ginter, T.N.; Gross, C.J.; Grzywacz, R.; Janas, Z.; Karny, M.; McConnell, J.W.; Toth, K.S.; Rykaczewski, K.; Zganjar, E. F.

    2000-01-01

    Great progress has been made in the last 20 years in the study of proton emission from unstable nuclei, but the prospects for additional strides in the next several years are bright. The present main limitations on the study of proton radioactivity are related to the inability to produce copious quantities of nuclides beyond the proton drip line, and the difficulty of measuring proton radioactivity of a mass-separated nucleus in the first few microseconds of its existence. At the Holifield Facility we will attack the second of these limitations by using new signal processing CAMAC modules DGF-4C. Digitizing of the preamplifier signals should enable the analysis of a proton decay occurring at times even less than 1 microsecond after an implant in a strip detector. In the same process, the threshold energy at which we can make measurements will be lowered. These two things will hopefully enable the measurement of lower-energy, but faster decays of isotopes in the 100 Sn region and below. For the latter region, the proton decays crucial for a rp-process scenario are of particular interest (e.g. 69 Br decay). Secondly, for very short-lived species, we plan to make measurements (without residue separation) at points much closer to the target, thus reducing the flight time between the target and detector. As more intense radioactive beams become available, eg. 56 Ni, we will utilize these to produce more neutron-deficient nuclides by use of colder reactions than is possible with stable beams. In some cases where delayed proton emitters are present in the same isobaric chain, the use of the cold reactions with radioactive beams can provide purer samples of the isotope of interest, with a reduction in background from the delayed proton emitters in the same mass chain

  7. Manipulating the Electronic Excited State Energies of Pyrimidine-Based Thermally Activated Delayed Fluorescence Emitters To Realize Efficient Deep-Blue Emission.

    Science.gov (United States)

    Komatsu, Ryutaro; Ohsawa, Tatsuya; Sasabe, Hisahiro; Nakao, Kohei; Hayasaka, Yuya; Kido, Junji

    2017-02-08

    The development of efficient and robust deep-blue emitters is one of the key issues in organic light-emitting devices (OLEDs) for environmentally friendly, large-area displays or general lighting. As a promising technology that realizes 100% conversion from electrons to photons, thermally activated delayed fluorescence (TADF) emitters have attracted considerable attention. However, only a handful of examples of deep-blue TADF emitters have been reported to date, and the emitters generally show large efficiency roll-off at practical luminance over several hundreds to thousands of cd m -2 , most likely because of the long delayed fluorescent lifetime (τ d ). To overcome this problem, we molecularly manipulated the electronic excited state energies of pyrimidine-based TADF emitters to realize deep-blue emission and reduced τ d . We then systematically investigated the relationships among the chemical structure, properties, and device performances. The resultant novel pyrimidine emitters, called Ac-XMHPMs (X = 1, 2, and 3), contain different numbers of bulky methyl substituents at acceptor moieties, increasing the excited singlet (E S ) and triplet state (E T ) energies. Among them, Ac-3MHPM, with a high E T of 2.95 eV, exhibited a high external quantum efficiency (η ext,max ) of 18% and an η ext of 10% at 100 cd m -2 with Commission Internationale de l'Eclairage chromaticity coordinates of (0.16, 0.15). These efficiencies are among the highest values to date for deep-blue TADF OLEDs. Our molecular design strategy provides fundamental guidance to design novel deep-blue TADF emitters.

  8. Beta-delayed fission and neutron emission calculations for the actinide cosmochronometers

    International Nuclear Information System (INIS)

    Meyer, B.S.; Howard, W.M.; Mathews, G.J.; Takahashi, K.; Moeller, P.; Leander, G.A.

    1989-01-01

    The Gamow-Teller beta-strength distributions for 19 neutron-rich nuclei, including ten of interest for the production of the actinide cosmochronometers, are computed microscopically with a code that treats nuclear deformation explicitly. The strength distributions are then used to calculate the beta-delayed fission, neutron emission, and gamma deexcitation probabilities for these nuclei. Fission is treated both in the complete damping and WKB approximations for penetrabilities through the nuclear potential-energy surface. The resulting fission probabilities differ by factors of 2 to 3 or more from the results of previous calculations using microscopically computed beta-strength distributions around the region of greatest interest for production of the cosmochronometers. The indications are that a consistent treatment of nuclear deformation, fission barriers, and beta-strength functions is important in the calculation of delayed fission probabilities and the production of the actinide cosmochronometers. Since we show that the results are very sensitive to relatively small changes in model assumptions, large chronometric ages for the Galaxy based upon high beta-delayed fission probabilities derived from an inconsistent set of nuclear data calculations must be considered quite uncertain

  9. Attenuation and Emittance Growth of 450 GeV and 7 TeV Proton Beams in Low-Z Absorber Elements

    CERN Document Server

    Kadi, Y; Goddard, B; Schmidt, R

    2004-01-01

    The intensity of the LHC beams will be several orders of magnitude above the damage thresholds for equipment. Passive protection of accelerator equipment against failures during beam transfer, injection and dumping of the beam with diluters and collimators is foreseen. These protection devices must be robust in case of beam impact, and low-Z materials such as carbon are favored. In these diluters, the reduction of the energy density is determined both by the attenuation due to inelastic nuclear collisions and by the emittance growth of the surviving protons due to elastic scattering processes. The physics principles leading to attenuation and emittance growth for a hadron beam traversing matter are summarised, and FLUKA simulation results for 450 GeV and 7 TeV proton beams on low-Z absorbers are compared with these predictions. Design criteria for the LHC absorbers are derived from these results.

  10. New β-delayed proton lines from 23Al

    International Nuclear Information System (INIS)

    Kirsebom, O.S.; Fynbo, H.O.U.; Riisager, K.; Jokinen, A.; Saastamoinen, A.; Aeystoe, J.; Madurga, M.; Tengblad, O.

    2011-01-01

    We report on a new measurement of the β-delayed proton spectrum of 23 Al. Higher statistics compared to previous measurements allow us to identify new proton lines in the energy range 1-2 MeV. A statistical analysis of the observed β strength shows that the B (GT) values are fully consistent with having a Porter-Thomas distribution. This is indicative of chaotic behaviour and implies that only the average β strength carries physical meaning. (orig.)

  11. Validation of FLUKA calculated cross-sections for radioisotope production in proton-on-target collisions at proton energies around 1 GeV

    CERN Document Server

    Felcini, M

    2006-01-01

    The production cross-sections of several radioisotopes induced by 1 GeV protons impinging on different target materials have been calculated using the FLUKA Monte Carlo and compared to measured cross-sections. The emphasis of this study is on the production of alpha and beta/gamma emitters of interest for activation evaluations at a research complex, such as the EURISOL complex, using several MW power proton driver at an energy of 1 GeV. The comparisons show that in most of the cases of interest for such evaluations, the FLUKA Monte Carlo reproduces radioisotope production cross-sections within less than a factor of two with respect to the measured values. This result implies that the FLUKA calculations are adequately accurate for proton induced activation estimates at a 1 GeV high power proton driver complex.

  12. β-particle energy-summing correction for β-delayed proton emission measurements

    Energy Technology Data Exchange (ETDEWEB)

    Meisel, Z., E-mail: meisel@ohio.edu [Institute of Nuclear and Particle Physics, Department of Physics and Astronomy, Ohio University, Athens, OH 45701 (United States); Joint Institute for Nuclear Astrophysics – Center for the Evolution of the Elements (United States); Santo, M. del [Joint Institute for Nuclear Astrophysics – Center for the Evolution of the Elements, National Superconducting Cyclotron Laboratory, Michigan State University, East Lansing, MI 48824 (United States); Crawford, H.L. [Nuclear Science Division, Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Cyburt, R.H. [Joint Institute for Nuclear Astrophysics – Center for the Evolution of the Elements, National Superconducting Cyclotron Laboratory, Michigan State University, East Lansing, MI 48824 (United States); Grinyer, G.F. [Grand Accélérateur National d' Ions Lourds (GANIL), CEA/DRF-CNRS/IN2P3, Bvd Henri Becquerel, Caen 14076 (France); Langer, C. [Joint Institute for Nuclear Astrophysics – Center for the Evolution of the Elements, Institute for Applied Physics, Goethe University Frankfurt am Main, 60438 Frankfurt am Main (Germany); Montes, F. [Joint Institute for Nuclear Astrophysics – Center for the Evolution of the Elements, National Superconducting Cyclotron Laboratory, Michigan State University, East Lansing, MI 48824 (United States); Schatz, H. [Joint Institute for Nuclear Astrophysics – Center for the Evolution of the Elements, National Superconducting Cyclotron Laboratory, Michigan State University, East Lansing, MI 48824 (United States); Department of Physics and Astronomy, Michigan State University, East Lansing, MI 48824 (United States); Smith, K. [Joint Institute for Nuclear Astrophysics – Center for the Evolution of the Elements, Department of Physics and Astronomy, University of Tennessee, Knoxville, TN 37996 (United States)

    2017-02-01

    A common approach to studying β-delayed proton emission is to measure the energy of the emitted proton and corresponding nuclear recoil in a double-sided silicon-strip detector (DSSD) after implanting the β-delayed proton-emitting (βp) nucleus. However, in order to extract the proton-decay energy, the measured energy must be corrected for the additional energy implanted in the DSSD by the β-particle emitted from the βp nucleus, an effect referred to here as β-summing. We present an approach to determine an accurate correction for β-summing. Our method relies on the determination of the mean implantation depth of the βp nucleus within the DSSD by analyzing the shape of the total (proton + recoil + β) decay energy distribution shape. We validate this approach with other mean implantation depth measurement techniques that take advantage of energy deposition within DSSDs upstream and downstream of the implantation DSSD.

  13. A background free double beta decay experiment

    International Nuclear Information System (INIS)

    Giomataris, I

    2011-01-01

    We present a new detection scheme for rejecting backgrounds in neutrino-less double beta decay experiments. It relies on the detection of Cherenkov light emitted by electrons in the MeV region. The momentum threshold is tuned to reach a good discrimination between background and good events. We consider many detector concepts and a range of target materials. The most promising is the high-pressure 136 Xe emitter where the required energy threshold is easily adjusted. Combination of this concept and a high pressure Time Projection Chamber could provide an optimal solution. A simple and low cost effective solution is the use of the Spherical Proportional Counter that provides, using a single read-out channel, two delayed signals from ionization and Cherenkov light. In solid-state double beta decay emitters, because of its higher density, the considered process is out of energy range. An escape will be the fabrication of double decay emitters having lower density by using for instance the aerogel technique. It is surprising that a technology used for particle identification in high-energy physics becomes a powerful tool for rejecting backgrounds in such low-energy experiments.

  14. Collateral sensitivity between aminoglycosides and beta-lactam antibiotics depends on active proton pumps.

    Science.gov (United States)

    Azimi, Leila; Rastegar Lari, Abdolaziz

    2017-11-01

    Selection inversion is the hypothesis for antibiotic resistant inhabitation in bacteria and collateral sensitivity is one of the proposed phenomena for achievement of this hypothesis. The presence of collateral sensitivity associated with the proton motivation pump between the aminoglycosides and beta-lactam group of antibiotics is one of the examples of collateral sensitivity in some studies. The aim of this study was to demonstrate that collateral sensitivity between aminoglycosides and beta-lactam antibiotics associated with proton motivation pump may not be true in all cases. In this study, 100 Pseudomonas aeruginosa were surveyed. Gentamicin and imipenem-resistant strains were confirmed by disc diffusion method and MIC. Active proton motivation pumps were screened by pumps inhibitor. Semi-quantitative Real-Time PCR assay was used to confirm gene overexpression. Seventy-six and 79 out of 100 strains were resistant to gentamicin and imipenem, respectively. Seventy-five strains were resistant to both gentamicin and imipenem. The results of proton pump inhibitor test showed the involvement of active proton motivation pump in 22 of 75 imipenem- and gentamicin-resistant strains. According to Real - Time PCR assay, mexX efflux gene was overexpressed in the majority of isolates tested. The collateral sensitivity effect cannot explain the involvement of active proton motivation pumps in both imipenem and gentamicin-resistant strains simultaneously. Active and/or inactive proton pump in gentamicin-sensitive and/or resistant strains cannot be a suitable example for explanation of collateral sensitivity between aminoglycosides and beta-lactam antibiotics. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Cherenkov radiation imaging of beta emitters: in vitro and in vivo results

    International Nuclear Information System (INIS)

    Spinelli, Antonello E.; Boschi, Federico; D'Ambrosio, Daniela; Calderan, Laura; Marengo, Mario; Fenzi, Alberto; Menegazzi, Marta; Sbarbati, Andrea; Del Vecchio, Antonella; Calandrino, Riccardo

    2011-01-01

    The main purpose of this work was to investigate both in vitro and in vivo Cherenkov radiation (CR) emission coming from 18 F and 32 P. The main difference between 18 F and 32 P is mainly the number of the emitted light photons, more precisely the same activity of 32 P emits more CR photons with respect to 18 F. In vitro results obtained by comparing beta counter measurements with photons average radiance showed that Cherenkov luminescence imaging (CLI) allows quantitative tracer activity measurements. In order to investigate in vivo the CLI approach, we studied an experimental xenograft tumor model of mammary carcinoma (BB1 tumor cells). Cherenkov in vivo dynamic whole body images of tumor bearing mice were acquired and the tumor tissue time activity curves reflected the well-known physiological accumulation of 18 F-FDG in malignant tissues with respect to normal tissues. The results presented here show that it is possible to use conventional optical imaging devices for in vitro or in vivo study of beta emitters.

  16. Cherenkov radiation imaging of beta emitters: in vitro and in vivo results

    Energy Technology Data Exchange (ETDEWEB)

    Spinelli, Antonello E., E-mail: spinelli.antonello@hsr.it [Medical Physics Department, S. Raffaele Scientific Institute, Via Olgettina N. 60, Milan (Italy); Boschi, Federico [Department of Morphological-Biomedical Sciences, University of Verona, Strada Le Grazie N. 8, Verona (Italy); D' Ambrosio, Daniela [Medical Physics Department, S. Orsola-Malpighi University Hospital, via Massarenti N. 9, Bologna (Italy); Calderan, Laura [Department of Morphological-Biomedical Sciences, University of Verona, Strada Le Grazie N. 8, Verona (Italy); Marengo, Mario [Medical Physics Department, S. Orsola-Malpighi University Hospital, via Massarenti N. 9, Bologna (Italy); Fenzi, Alberto [Department of Morphological-Biomedical Sciences, University of Verona, Strada Le Grazie N. 8, Verona (Italy); Menegazzi, Marta [Department of Life and Reproduction Sciences, University of Verona, Strada Le Grazie N. 8, Verona (Italy); Sbarbati, Andrea [Department of Morphological-Biomedical Sciences, University of Verona, Strada Le Grazie N. 8, Verona (Italy); Del Vecchio, Antonella; Calandrino, Riccardo [Medical Physics Department, S. Raffaele Scientific Institute, Via Olgettina N. 60, Milan (Italy)

    2011-08-21

    The main purpose of this work was to investigate both in vitro and in vivo Cherenkov radiation (CR) emission coming from {sup 18}F and {sup 32}P. The main difference between {sup 18}F and {sup 32}P is mainly the number of the emitted light photons, more precisely the same activity of {sup 32}P emits more CR photons with respect to {sup 18}F. In vitro results obtained by comparing beta counter measurements with photons average radiance showed that Cherenkov luminescence imaging (CLI) allows quantitative tracer activity measurements. In order to investigate in vivo the CLI approach, we studied an experimental xenograft tumor model of mammary carcinoma (BB1 tumor cells). Cherenkov in vivo dynamic whole body images of tumor bearing mice were acquired and the tumor tissue time activity curves reflected the well-known physiological accumulation of {sup 18}F-FDG in malignant tissues with respect to normal tissues. The results presented here show that it is possible to use conventional optical imaging devices for in vitro or in vivo study of beta emitters.

  17. Gamma/neutron competition above the neutron separation energy in delayed neutron emitters

    Directory of Open Access Journals (Sweden)

    Valencia E.

    2014-03-01

    Full Text Available To study the β-decay properties of some well known delayed neutron emitters an experiment was performed in 2009 at the IGISOL facility (University of Jyväskylä in Finland using Total Absorption γ-ray Spectroscopy (TAGS technique. The aim of these measurements is to obtain the full β-strength distribution below the neutron separation energy (Sn and the γ/neutron competition above. This information is a key parameter in nuclear technology applications as well as in nuclear astrophysics and nuclear structure. Preliminary results of the analysis show a significant γ-branching ratio above Sn.

  18. Validation the quantification of beta emitters activity in urine by scintillation spectrometry in the liquid phase

    International Nuclear Information System (INIS)

    Sierra, I.; Hernandez, C.; Benito, P.; Lopez, C.

    2013-01-01

    In this paper the methodology used in the validation of the technique for quantifying activity of some beta emitters in urine ( 3 H, 1 4C, 3 5S, 3 2P and 9 0Sr) by scintillation spectrometry Liquid Phase (Liquid Scintillation Counting, LSC) is described in bio elimination Laboratory Service CIEMAT Radiation Dosimetry accredited since last year for carrying out assays measure radiation dose based on ISO forth above. (Author)

  19. Study of $\\beta$-delayed neutron decay of $^{8}$He

    CERN Multimedia

    The goal of the present proposal is to study $\\beta$-delayed neutron decay branch of $^{8}$He. The energy spectra of the emitted neutrons will be measured in the energy range of 0.1 – 6 MeV using the VANDLE spectrometer. Using coincident $\\gamma$-ray measurement, components of the spectrum corresponding to transitions to the ground- and first- excited states of $^{7}$Li will be disentangled. The new data will allow us to get a more complete picture of the $\\beta$-decay of $^{8}$He and to clarify the discrepancy between the B(GT) distributions derived from the $\\beta$-decay and $^{8}$He(p, n)$^{8}$Li reaction studies.

  20. Energy calibration of a silicon detector using pure beta-emitters

    International Nuclear Information System (INIS)

    Borras, C.; Los Arcos, J.M.

    1992-01-01

    Energy calibration of Si detectors used in electron spectroscopy is commonly performed with conversion electron sources or monoenergetic electrons beams, which are preferred against beta emitters due to the problems arising from their continuous spectra. This paper presents a simple calibration procedure for a PIP-type silicon detector, using 1 4C, 1 47m, 9 9Tc and 4 5Ca, that is based on the correspondence between the average channel observed in the experimental spectrum and the mean energy evaluated from the theoretical Fermi distribution for each nuclide. First, a method for evaluating the average channel in the experimental spectrum distorted by the electronic noise is described and its uncertainty estimated. Then, the channel-energy relation ship is established by least squares fitting modified to account for uncertainties in both variables. The calibration has been successfully verified with 147Pm and 109Cs source, showing discrepancies not greater than 2.5%, within the uncertainties due to the detector resolution and the sources features. (author)

  1. Energy Calibration of a Silicon Detector Using Pure Beta-Emitters

    International Nuclear Information System (INIS)

    Borras, C.; Arcos, J. M. los

    1992-01-01

    Energy calibration of SI detectors used in electron spectroscopy 13 commonly performed with conversion electron sources or monoenergetic electrons beams, which are preferred against beta emitters due to the problems arising from their continuous spectra. This paper presents a simple calibration procedure for a PIP-type silicon detector, using 14C, 147Pm, 99 T c and 45Ca sources, that is based on the correspondence between the average channel observed in the experimental spectrum and the mean energy evaluated from the theoretical Fermi distribution for each nuclide. First, a method for evaluating the average channel in the experimental spectrum distorted by the electronic noise is described and its uncertainty estimated. Then, the channel-energy relation ship is established by least squares fitting modified to account for uncertainties in both variables.The calibration has been successfully verified with 147Pm and '09cd sources, showing discrepaneles not greater than 2.5%, within the uncertainties due to the detector resolution and the sources features. (Author)

  2. Particle unstable excited states in /sup 9/Be influence of beta recoil and width on delayed particle spectra

    CERN Document Server

    Nyman, G H; Jonson, B; Kratz, K L; Larsson, P O; Mattsson, S; Ziegert, W

    1981-01-01

    The light nucleus /sup 9/Be has been studied through the emission of beta-delayed neutrons and alpha particles from /sup 9/Li. The activity is produced at the ISOLDE facility in fragmentation reactions induced either by 600 MeV proton or 910 MeV /sup 3/He beams from the CERN Synchro-cyclotron. After mass separation neutron spectra are recorded using /sup 3/He-filled proportional counters, while surface barrier detectors are used for the spectroscopy of alpha particles. Effects on the spectrum shape induced by recoil and polarization phenomena as well as large widths of the intermediate states are discussed. (14 refs).

  3. Thermally Activated Delayed Fluorescence Emitters for Deep Blue Organic Light Emitting Diodes: A Review of Recent Advances

    Directory of Open Access Journals (Sweden)

    Thanh-Tuân Bui

    2018-03-01

    Full Text Available Organic light-emitting diodes offer attractive perspectives for the next generation display and lighting technologies. The potential is huge and the list of potential applications is almost endless. So far, blue emitters still suffer from noticeably inferior electroluminescence performances in terms of efficiency, lifespan, color quality, and charge injection/transport when compared to that of the other colors. Emitting materials matching the NTSC standard blue of coordinates (0.14, 0.08 are extremely rare and still constitutes the focus of numerous academic and industrial researches. In this context, we review herein the recent developments on highly emissive deep-blue thermally activated delayed fluorescence emitters that constitute the third-generation electroluminescent materials.

  4. Production of alpha emitters for therapy

    International Nuclear Information System (INIS)

    Vucina, J.; Orlic, M.; Lukic, D.

    2006-01-01

    The basis for the introduction of alpha emitters into nuclear medical practice are their radiobiological properties. High LET values and short ranges in biological tissues are advantageous in comparison with nowadays most often used beta emitters, primarily 90 Y and 131 I. Given are the most important criteria for the introduction of a given radionuclide in the routine use. Shown are the procedures for the production of the most important alpha emitters 211 At, 212 Bi and 213 Bi. (author)

  5. Internal bremsstrahlung spectra of the allowed. beta. emitters /sup 32/P, /sup 35/S and /sup 45/Ca

    Energy Technology Data Exchange (ETDEWEB)

    Powar, M S; Singh, M [Punjabi Univ., Patiala (India). Dept. of Physics

    1976-01-01

    A study of Coulomb field effects in internal bremsstrahlung (IB) has been undertaken by measuring the IB spectra for the allowed beta emitters /sup 32/P, /sup 35/S and /sup 45/Ca in the photon energy intervals of 50 to 1600 keV, 25 to 150 keV and 30 to 240 keV respectively. The experimental results show increasing positive departures from the KUB and Coulomb-corrected theories of Lewis and Ford, and Nilsson, with decreasing beta end-point energy. In the case of /sup 35/S the experimental results are 40 % higher than the more exact theory of Struzynski and Pollock for this isotope.

  6. Advanced low-beta cavity development for proton and ion accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Conway, Z. A.; Kelly, M. P.; Ostroumov, P. N.

    2015-05-01

    Recent developments in designing and processing low-beta superconducting cavities at Argonne National Laboratory are very encouraging for future applications requiring compact proton and ion accelerators. One of the major benefits of these accelerating structures is achieving real-estate accelerating gradients greater than 3 MV/m very efficiently either continuously or for long-duty cycle operation (>1%). The technology has been implemented in low-beta accelerator cryomodules for the Argonne ATLAS heavy-ion linac where the cryomodules are required to have real-estate gradients of more than 3 MV/m. In offline testing low-beta cavities with even higher gradients have already been achieved. This paper will review this work where we have achieved surface fields greater than 166 mT magnetic and 117 MV/m electric in a 72 MHz quarter-wave resonator optimized for beta = 0.077 ions.

  7. Study of proton radioactivities

    Energy Technology Data Exchange (ETDEWEB)

    Davids, C.N.; Back, B.B.; Henderson, D.J. [and others

    1995-08-01

    About a dozen nuclei are currently known to accomplish their radioactive decay by emitting a proton. These nuclei are situated far from the valley of stability, and mark the very limits of existence for proton-rich nuclei: the proton drip line. A new 39-ms proton radioactivity was observed following the bombardment of a {sup 96}Ru target by a beam of 420-MeV {sup 78}Kr. Using the double-sided Si strip detector implantation system at the FMA, a proton group having an energy of 1.05 MeV was observed, correlated with the implantation of ions having mass 167. The subsequent daughter decay was identified as {sup 166}Os by its characteristic alpha decay, and therefore the proton emitter is assigned to the {sup 167}Ir nucleus. Further analysis showed that a second weak proton group from the same nucleus is present, indicating an isomeric state. Two other proton emitters were discovered recently at the FMA: {sup 171}Au and {sup 185}Bi, which is the heaviest known proton radioactivity. The measured decay energies and half-lives will enable the angular momentum of the emitted protons to be determined, thus providing spectroscopic information on nuclei that are beyond the proton drip line. In addition, the decay energy yields the mass of the nucleus, providing a sensitive test of mass models in this extremely proton-rich region of the chart of the nuclides. Additional searches for proton emitters will be conducted in the future, in order to extend our knowledge of the location of the proton drip line.

  8. Advanced low-beta cavity development for proton and ion accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Conway, Z.A., E-mail: zconway@anl.gov; Kelly, M.P.; Ostroumov, P.N.

    2015-05-01

    Recent developments in designing and processing low-beta superconducting cavities at Argonne National Laboratory are very encouraging for future applications requiring compact proton and ion accelerators. One of the major benefits of these accelerating structures is achieving real-estate accelerating gradients greater than 3 MV/m very efficiently either continuously or for long-duty cycle operation (>1%). The technology has been implemented in low-beta accelerator cryomodules for the Argonne ATLAS heavy-ion linac where the cryomodules are required to have real-estate gradients of more than 3 MV/m. In offline testing low-beta cavities with even higher gradients have already been achieved. This paper will review this work where we have achieved surface fields greater than 166 mT magnetic and 117 MV/m electric in a 72 MHz quarter-wave resonator optimized for β = 0.077 ions.

  9. Advanced low-beta cavity development for proton and ion accelerators

    International Nuclear Information System (INIS)

    Conway, Z.A.; Kelly, M.P.; Ostroumov, P.N.

    2015-01-01

    Recent developments in designing and processing low-beta superconducting cavities at Argonne National Laboratory are very encouraging for future applications requiring compact proton and ion accelerators. One of the major benefits of these accelerating structures is achieving real-estate accelerating gradients greater than 3 MV/m very efficiently either continuously or for long-duty cycle operation (>1%). The technology has been implemented in low-beta accelerator cryomodules for the Argonne ATLAS heavy-ion linac where the cryomodules are required to have real-estate gradients of more than 3 MV/m. In offline testing low-beta cavities with even higher gradients have already been achieved. This paper will review this work where we have achieved surface fields greater than 166 mT magnetic and 117 MV/m electric in a 72 MHz quarter-wave resonator optimized for β = 0.077 ions

  10. Dry-boxes for manipulation of high-energy {beta} emitters; Bottes pour manipulation d'emetteurs {beta} energiques

    Energy Technology Data Exchange (ETDEWEB)

    Boclet, K; Laurent, H [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    Because of the thinners of latex or neoprene gloves and the high intensity of Bremsstrahlung radiation, manipulation of pure high-energy {beta}{sup -} emitters is impossible in ordinary dry-boxes. There are many types of box equipped with heavy lead or steel protection, but their use for radioelements such as {sup 32}P, {sup 90}Sr, {sup 90}Y is not justified. We have devised units known as 'tong boxes' which, while retaining much of the flexibility of operation found in dry-boxes, provide adequate protection. 1 curie of {sup 32}P placed in the centre of the enclosure gives about 15 mR/ 8 h. at the part of the wall closest to the source. (author) [French] La faible epaisseur des gants de latex ou de neoprene et l'importance du rayonnement de freinage rendent impossible la manipulation des emetteurs {beta}{sup -} purs energiques dans des boites a gants normales. Il existe de nombreux types d'enceintes dotees d'une forte protection de plomb ou d'acier dont l'emploi n'est pas justifie pour des radioelements tels que {sup 32}P, {sup 90}Sr, {sup 90}Y. Nous avons realise des ensembles appeles 'Boites a Pinces', qui tout en conservant une grande partie de la souplesse d'utilisation des boites a gants sont dotees d'une protection suffisante. 1 curie de {sup 32}P place au centre de l'enceinte donne environ 15 mR/ 8 h au contact de la paroi la plus rapprochee de la source. (auteur)

  11. Realizing Highly Efficient Solution-Processed Homojunction-Like Sky-Blue OLEDs by Using Thermally Activated Delayed Fluorescent Emitters Featuring an Aggregation-Induced Emission Property.

    Science.gov (United States)

    Wu, Kailong; Wang, Zian; Zhan, Lisi; Zhong, Cheng; Gong, Shaolong; Xie, Guohua; Yang, Chuluo

    2018-04-05

    Two new blue emitters, i.e., bis-[2-(9,9-dimethyl-9,10-dihydroacridine)-phenyl]-sulfone ( o-ACSO2) and bis-[3-(9,9-dimethyl-9,10-dihydroacridine)-phenyl]-sulfone ( m-ACSO2), with reserved fine thermally activated delayed fluorescent (TADF) nature and simply tuned thermal and optoelectronic properties, were synthesized by isomer engineering. The meta-linking compound, i.e., m-ACSO2, obtains the highest photoluminescence quantum yield with a small singlet-triplet energy gap, a moderate delayed fluorescent lifetime, excellent solubility, and neat film homogeneity. Due to its unique aggregation-induced emission (AIE) character, neat film-based heterojunction-like organic light-emitting diodes (OLEDs) are achievable. By inserting an excitonic inert exciton-blocking layer, the PN heterojunction-like emission accompanied by intefacial exciplex was shifted to a homojunction-like channel mainly from the AIE emitter itself, providing a new tactic to generate efficient blue color from neat films. The solution-processed nondoped sky-blue OLED employing m-ACSO2 as emitter with homojunction-like emission achieved a maximum external quantum efficiency of 17.2%. The design strategies presented herein provide practical methods to construct efficient blue TADF dyes and realize high-performance blue TADF devices.

  12. Helium burning: a further measurement of the beta-delayed alpha-particle emission of 16 Na

    International Nuclear Information System (INIS)

    Gai, Moshe

    1997-01-01

    The 12 C (α,γ) 16 O is a key (but still unknown) reaction in helium burning. Several attempts to constrain the p-wave S-factor at Helium burning temperatures (200 M K) using the beta-delayed alpha-particle emission of 16 N have been made. However, some discrepancy exists between the spectra measured at Settle and that of TRIUMF. We have improved our previous study of the beta-delayed alpha-particle emission of 16 N by improving our statistical sample (by more than a factor of 5), improving the energy resolution of the experiment (by 20%), and in understanding our line shape, deduced from measured quantities. Our newly measured spectrum of the beta-delayed alpha-particle emission of 16 N is consistent with the Seattle ('95) data, as well as an earlier experiment performed at Mains ('71) and is not consistent with the TRIUMF ('94) data. (author)

  13. Additional results from the β-delayed proton decays of 27P and 31Cl

    International Nuclear Information System (INIS)

    Ognibene, T.J.; Powell, J.; Moltz, D.M.; Rowe, M.W.; Cerny, J.

    1996-01-01

    β-delayed proton decays of the nuclides 27 P and 31 Cl were measured using the helium-jet recoil collection technique and low-energy particle identification detector telescopes. In 27 P, two new proton groups at 466±3 keV and 612±2 keV, with intensities of 9±2% and 97±3% relative to the main (100%) group at 731±2 keV, were discovered. Additionally, during the 27 P experiments, a new proton transition was identified following the β decay of 28 P. This group, at a proton energy of 1452±4 keV, had a 2±1% intensity relative to the 100% group at 679±1 keV. A total 27 P β-delayed proton branch of 0.07% was estimated. The experimental Gamow-Teller β-decay strengths of the observed transitions from 27 P were compared to results from shell model calculations. A search for new proton transitions in 31 Cl, the next member of this A=4n+3, T z =-3/2 series, was unsuccessful. However, several proton peaks that had been previously assigned to 31 Cl decay were shown to be from the decay of 25 Si. copyright 1996 The American Physical Society

  14. An experimental approach to improve the Monte Carlo modelling of offline PET/CT-imaging of positron emitters induced by scanned proton beams

    International Nuclear Information System (INIS)

    Bauer, J; Unholtz, D; Kurz, C; Parodi, K

    2013-01-01

    We report on the experimental campaign carried out at the Heidelberg Ion-Beam Therapy Center (HIT) to optimize the Monte Carlo (MC) modelling of proton-induced positron-emitter production. The presented experimental strategy constitutes a pragmatic inverse approach to overcome the known uncertainties in the modelling of positron-emitter production due to the lack of reliable cross-section data for the relevant therapeutic energy range. This work is motivated by the clinical implementation of offline PET/CT-based treatment verification at our facility. Here, the irradiation induced tissue activation in the patient is monitored shortly after the treatment delivery by means of a commercial PET/CT scanner and compared to a MC simulated activity expectation, derived under the assumption of a correct treatment delivery. At HIT, the MC particle transport and interaction code FLUKA is used for the simulation of the expected positron-emitter yield. For this particular application, the code is coupled to externally provided cross-section data of several proton-induced reactions. Studying experimentally the positron-emitting radionuclide yield in homogeneous phantoms provides access to the fundamental production channels. Therefore, five different materials have been irradiated by monoenergetic proton pencil beams at various energies and the induced β + activity subsequently acquired with a commercial full-ring PET/CT scanner. With the analysis of dynamically reconstructed PET images, we are able to determine separately the spatial distribution of different radionuclide concentrations at the starting time of the PET scan. The laterally integrated radionuclide yields in depth are used to tune the input cross-section data such that the impact of both the physical production and the imaging process on the various positron-emitter yields is reproduced. The resulting cross-section data sets allow to model the absolute level of measured β + activity induced in the investigated

  15. An experimental approach to improve the Monte Carlo modelling of offline PET/CT-imaging of positron emitters induced by scanned proton beams

    Science.gov (United States)

    Bauer, J.; Unholtz, D.; Kurz, C.; Parodi, K.

    2013-08-01

    We report on the experimental campaign carried out at the Heidelberg Ion-Beam Therapy Center (HIT) to optimize the Monte Carlo (MC) modelling of proton-induced positron-emitter production. The presented experimental strategy constitutes a pragmatic inverse approach to overcome the known uncertainties in the modelling of positron-emitter production due to the lack of reliable cross-section data for the relevant therapeutic energy range. This work is motivated by the clinical implementation of offline PET/CT-based treatment verification at our facility. Here, the irradiation induced tissue activation in the patient is monitored shortly after the treatment delivery by means of a commercial PET/CT scanner and compared to a MC simulated activity expectation, derived under the assumption of a correct treatment delivery. At HIT, the MC particle transport and interaction code FLUKA is used for the simulation of the expected positron-emitter yield. For this particular application, the code is coupled to externally provided cross-section data of several proton-induced reactions. Studying experimentally the positron-emitting radionuclide yield in homogeneous phantoms provides access to the fundamental production channels. Therefore, five different materials have been irradiated by monoenergetic proton pencil beams at various energies and the induced β+ activity subsequently acquired with a commercial full-ring PET/CT scanner. With the analysis of dynamically reconstructed PET images, we are able to determine separately the spatial distribution of different radionuclide concentrations at the starting time of the PET scan. The laterally integrated radionuclide yields in depth are used to tune the input cross-section data such that the impact of both the physical production and the imaging process on the various positron-emitter yields is reproduced. The resulting cross-section data sets allow to model the absolute level of measured β+ activity induced in the investigated

  16. Harvesting Triplet Excitons with Exciplex Thermally Activated Delayed Fluorescence Emitters toward High Performance Heterostructured Organic Light-Emitting Field Effect Transistors.

    Science.gov (United States)

    Song, Li; Hu, Yongsheng; Liu, Zheqin; Lv, Ying; Guo, Xiaoyang; Liu, Xingyuan

    2017-01-25

    The utilization of triplet excitons plays a key role in obtaining high emission efficiency for organic electroluminescent devices. However, to date, only phosphorescent materials have been implemented to harvest the triplet excitons in the organic light-emitting field effect transistors (OLEFETs). In this work, we report the first incorporation of exciplex thermally activated delayed fluorescence (TADF) emitters in heterostructured OLEFETs to harvest the triplet excitons. By developing a new kind of exciplex TADF emitter constituted by m-MTDATA (4,4',4″-tris(N-3-methylphenyl-N-phenylamino)triphenylamine) as the donor and OXD-7 (1,3-bis[2-(4-tert-butylphenyl)-1,3,4-oxadiazo-5-yl]benzene) as the acceptor, an exciton utilization efficiency of 74.3% for the devices was achieved. It is found that the injection barrier between hole transport layer and emission layer as well as the ratio between donor and acceptor would influence the external quantum efficiency (EQE) significantly. Devices with a maximum EQE of 3.76% which is far exceeding the reported results for devices with conventional fluorescent emitters were successfully demonstrated. Moreover, the EQE at high brightness even outperformed the result for organic light-emitting diode based on the same emitter. Our results demonstrate that the exciplex TADF emitters can be promising candidates to develop OLEFETs with high performance.

  17. A note on the relationship between the emittance, the beta function and the energy in a linear collider

    International Nuclear Information System (INIS)

    Rees, J.

    1986-11-01

    Scaling laws for linear colliders are considered for the case of laterally round Gaussian beams and for the case that mutual pinching of the beams can be ignored. Based on these assumptions, the relationship is found between the interaction area, beta function, beam emittance, and energy for a linear collider in order to show the need for substantial improvements in the feasible values of accelerator parameters to reach a center of mass energy of 0.7 TeV. Pinch is then taken into account

  18. Low emittance configuration for spear

    International Nuclear Information System (INIS)

    Blumberg, L.N.; Harris, J.; Stege, R.; Cerino, J.; Hettel, R.; Hofmann, A.; Liu, R.Z.; Wiedemann, H.; Winick, H.

    1985-01-01

    The quality of synchrotron radiation beams from SPEAR, in particular the brilliance of undulator radiation, can be improved significantly by reducing the emittance of the stored electron beam. A reduction of the horizontal emittance by a factor of 3.5 to a value of 130 nanometer-radians (nm-r) at 3 GeV has been achieved by using stronger focussing, mainly in the horizontal plane. The low emittance configuration also reduces the dispersion and vertical beta functions in the straight sections, making them more suitable for wigglers. The higher betatron tunes lead to a larger phase advance between the two kickers, which has to be corrected during injection by shunting current from some quadrupoles. The configuration was optimized within SPEAR hardware limitations and tested for dynamic aperture with the tracking program PATRICIA. After implementation of this scheme, beam was successfully injected and accumulated. The measured emittance of the stored beam was in agreement with calculations. Presently the configuration is being made operational

  19. First measurement of several $\\beta$-delayed neutron emitting isotopes beyond N=126

    CERN Document Server

    Caballero-Folch, R.; Agramunt, J.; Algora, A.; Ameil, F.; Arcones, A.; Ayyad, Y.; Benlliure, J.; Borzov, I.N.; Bowry, M.; Calvino, F.; Cano-Ott, D.; Cortés, G.; Davinson, T.; Dillmann, I.; Estrade, A.; Evdokimov, A.; Faestermann, T.; Farinon, F.; Galaviz, D.; García, A.R.; Geissel, H.; Gelletly, W.; Gernhäuser, R.; Gómez-Hornillos, M.B.; Guerrero, C.; Heil, M.; Hinke, C.; Knöbel, R.; Kojouharov, I.; Kurcewicz, J.; Kurz, N.; Litvinov, Y.; Maier, L.; Marganiec, J.; Marketin, T.; Marta, M.; Martínez, T.; Martínez-Pinedo, G.; Montes, F.; Mukha, I.; Napoli, D.R.; Nociforo, C.; Paradela, C.; Pietri, S.; Podolyák, Zs.; Prochazka, A.; Rice, S.; Riego, A.; Rubio, B.; Schaffner, H.; Scheidenberger, Ch.; Smith, K.; Sokol, E.; Steiger, K.; Sun, B.; Taín, J.L.; Takechi, M.; Testov, D.; Weick, H.; Wilson, E.; Winfield, J.S.; Wood, R.; Woods, P.; Yeremin, A.

    2016-01-01

    The $\\beta$-delayed neutron emission probabilities of neutron rich Hg and Tl nuclei have been measured together with $\\beta$-decay half-lives for 20 isotopes of Au, Hg, Tl, Pb and Bi in the mass region N$\\gtrsim$126. These are the heaviest species where neutron emission has been observed so far. These measurements provide key information to evaluate the performance of nuclear microscopic and phenomenological models in reproducing the high-energy part of the $\\beta$-decay strength distribution. In doing so, it provides important constraints to global theoretical models currently used in $r$-process nucleosynthesis.

  20. Up-Conversion Intersystem Crossing Rates in Organic Emitters for Thermally Activated Delayed Fluorescence: Impact of the Nature of Singlet vs Triplet Excited States

    KAUST Repository

    Samanta, Pralok Kumar; Kim, Dongwook; Coropceanu, Veaceslav; Bredas, Jean-Luc

    2017-01-01

    The rates for up-conversion intersystem crossing (UISC) from the T1 state to the S1 state are calculated for a series of organic emitters with an emphasis on thermally activated delayed fluorescence (TADF) materials. Both the spin-orbit coupling

  1. New Therapeutic Approaches to Prevent or Delay Beta-Cell Failure in Diabetes

    Directory of Open Access Journals (Sweden)

    Ionica Floriana Elvira

    2015-09-01

    Full Text Available Background and aims: The most recent estimates of International Diabetes Federation indicate that 382 million people have diabetes, and the incidence of this disease is increasing. While in type 1 diabetes mellitus (T1DM beta-cell death is autoimmunemediated, type 2 diabetes mellitus (T2DM results from an interaction between genetic and environmental factors that impair beta-cell function and insulin action. Many people with T2DM remain unaware of their illness for a long time because symptoms may take years to appear or be recognized, while the body is affected by excess blood glucose. These patients are often diagnosed only when diabetes complications have already developed. The aim of this article was to perform a review based on literature data on therapeutic modalities to prevent/delay beta cell function decline. Material and Methods: We searched MEDLINE from 2000 to the present to identify the therapeutic approaches to prevent or delay beta-cell failure in patients with T2DM. Results and conclusions: Several common polymorphisms in genes linked to monogenic forms of diabetes appear to influence the response to T2DM pharmacotherapy. Recent studies report the role of the G protein coupled receptor 40 (GPR40, also known as Free Fatty Acids Receptor 1 (FFAR1 in the regulation of beta-cell function- CNX-011-67 (a GPR40 agonist has the potential to provide good and durable glycemic control in T2DM patients.

  2. Procedure to carry out leakage test in beta radiation sealed sources emitters of {sup 90}Sr/{sup 90}Y; Procedimiento para realizar prueba de fuga en fuentes selladas de radiacion beta emisoras de {sup 90}Sr/{sup 90}Y

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez R, J. T., E-mail: trinidad.alvarez@inin.gob.m [ININ, Departamento de Metrologia de Radiaciones Ionizantes, Laboratorio Secundario de Calibracion Dosimetrica, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2010-09-15

    In the alpha-beta room of the Secondary Laboratory of Dosimetric Calibration of the Metrology Department of Ionizing Radiations ophthalmic applicators are calibrated in absorbed dose terms in water D{sub w}; these applicators, basically are emitter sealed sources of pure beta radiation of {sup 90}Sr / {sup 90}Y. Concretely, the laboratory quality system indicates to use the established procedure for the calibration of these sources, which establishes the requirement of to carry out a leakage test, before to calibrate the source. However, in the Laboratory leakage test certificates sent by specialized companies in radiological protection services have been received, in which are used gamma spectrometry equipment s for beta radiation leakage tests, since it is not reliable to detect pure beta radiation with a scintillating detector with NaI crystal, (because it could detect the braking radiation produced in the detector). Therefore the Laboratory has had to verify the results of the tests with a correct technique, with the purpose of determining the presence of sources with their altered integrity and radioactive material leakage. The objective of this work is to describe a technique for beta activity measurement - of the standard ISO 7503, part 1 (1988) - and its application with a detector Gm plane (type pankage) in the realization of leakage tests in emitter sources of pure beta radiation, inside the mark of quality assurance indicated by the report ICRU 76. (Author)

  3. $\\beta$-delayed neutrons from oriented $^{137,139}$I and $^{87,89}$Br nuclei

    CERN Multimedia

    We propose a world-first measurement of the angular distribution of $\\beta$‐delayed n and $\\gamma$-radiation from oriented $^{137, 139}$I and $^{87,89}$Br nuclei, polarised at low temperature at the NICOLE facility. $\\beta$­-delayed neutron emission is an increasingly important decay mechanism as the drip line is approached and its detailed understanding is essential to phenomena as fundamental as the r‐process and practical as the safe operation of nuclear power reactors. The experiments offer sensitive tests of theoretical input concerning the allowed and first­‐forbidden $\\beta$‐decay strength, the spin-density of neutron emitting states and the partial wave barrier penetration as a function of nuclear deformation. In $^{137}$I and $^{87}$Br the decay feeds predominantly the ground state of the daughters $^{136}$Xe and $^{86}$Kr whereas in $^{139}$I and $^{89}$Br we will explore the use of n-$\\gamma$- coincidence to study neutron transitions to the first and second excited states in the daughters...

  4. New type of asymmetric fission in proton-rich nuclei

    CERN Document Server

    Andreyev, A N; Huyse, M; Van Duppen, P; Antalic, S; Barzakh, A; Bree, N; Cocolios, T E; Comas, V F; Diriken, J; Fedorov, D; Fedosseev, V; Franchoo, S; Heredia, J A; Ivanov, O; Koster, U; Marsh, B A; Nishio, K; Page, R D; Patronis, N; Seliverstov, M; Tsekhanovich, I; Van den Bergh, P; Van De Walle, J; Venhart, M; Vermote, S; Veselsky, M; Wagemans, C; Ichikawa, T; Iwamoto, A; Moller, P; Sierk, A J

    2010-01-01

    A very exotic process of ${\\beta}$-delayed fission of $^{180}$Tl is studied in detail by using resonant laser ionization with subsequent mass separation at ISOLDE (CERN). In contrast to common expectations, the fission-fragment mass distribution of the post-${\\beta}$-decay daughter nucleus $^{180}$Hg (N/Z=1.25) is asymmetric. This asymmetry is more surprising since a mass-symmetric split of this extremely neutron-deficient nucleus would lead to two $^{90}$Zr fragments, with magic N=50 and semimagic Z=40. This is a new type of asymmetric fission, not caused by large shell effects related to fragment magic proton and neutron numbers, as observed in the actinide region. The newly measured branching ratio for $\\beta$-delayed fission of $^{180}$Tl is 3.6(7)×10$^{-3}$%, approximately 2 orders of magnitude larger than in an earlier study.

  5. Studies and calculations of transverse emittance growth in proton storage rings

    International Nuclear Information System (INIS)

    Mane, S.R.; Jackson, G.

    1989-01-01

    When high energy storage rings are used to collide beams of particles and antiparticles for high energy physics experiments, it is important to obtain as high an integrated luminosity as possible. Reduction of integrated luminosity can arise from several factors, in particular from growth of the transverse beam sizes (transverse emittances). We have studied the problem of transverse emittance growth in high energy storage rings caused by random dipole noise kicks to the beam. A theoretical formula for the emittance growth rate is derived, and agreement is obtained with experimental measurements where noise of known amplitude and power spectrum was deliberately injected into the Fermilab Tevatron, to kick the beam randomly. In the experiment, phase noise was introduced into the Tevatron rf system, and the measured dependence of horizontal emittance growth on phase noise amplitude is compared against the theoretically derived response. (orig.)

  6. A low emittance configuration for spear

    International Nuclear Information System (INIS)

    Blumberg, L.N.; Cerino, J.; Harris, J.; Hettel, R.; Hofmann, A.; Liu, R.Z.; Stego, R.; Wiedemann, H.; Winick, H.

    1985-01-01

    The quality of synchrotron radiation beams from SPEAR, in particular the brilliance of undulator radiation, can be improved significantly by reducing the emittance of the stored electron beam. A reduction of the horizontal emittance by a factor of 3.5 to a value of 130 nanometer-radians (nm-r) at 3 GeV has been achieved by using stronger focussing, mainly in the horizontal plane. The low emittance configuration also reduces the dispersion and vertical beta functions in the straight sections, making them more suitable for wigglers. The higher betatron tunes lead to a larger phase advance between the two kickers, which has to be corrected during injection by shunting current from some quadrupoles. The configuration was optimized within SPEAR hardware limitations and tested for dynamic aperture with the tracking program PATRICIA. After implementation of this scheme, beam was successfully injected and accumulated. The measured emittance of the stored beam was in agreement with calculations. Presently the configuration is being made operational

  7. $\\beta$-delayed neutrons from oriented $^{137,139}$I and $^{87,89}$Br nuclei

    CERN Document Server

    Grzywacz, Robert; Stone, Nicholas; Köster, Ulli; Singh, Barlaj; Bingham, Carrol; Gaulard, S; Kolos, Karolina; Madurga, Miguel; Nikolov, J; Otsubo, T; Roccia, S; Veskovic, Miroslav; Walker, Phil; Walters, William

    2013-01-01

    We propose a world-­‐first measurement of the angular distribution of $\\beta$-­‐delayed n and $\\gamma$- radiation from oriented $^{137, 139}$I and $^{87,89}$Br nuclei, polarised at low temperature at the NICOLE facility. $\\beta$-­‐delayed neutron emission is an increasingly important decay mechanism as the drip line is approached and its detailed understanding is essential to phenomena as fundamental as the r‐process and practical as the safe operation of nuclear power reactors. The experiments offer sensitive tests of theoretical input concerning the allowed and first-­‐forbidden $\\beta$‐decay strength, the spin-­‐density of neutron emitting states and the partial wave barrier penetration as a function of nuclear deformation. In $^{137}$I and $^{87}$Br the decay feeds predominantly the ground state of the daughters $^{136}$Xe and $^{86}$Kr whereas in $^{139}$I and $^{89}$Br we will explore the use of n-$\\gamma$- coincidence to study neutron transitions to the first and second excited state...

  8. $^{11}$Be($\\beta$p), a quasi-free neutron decay?

    CERN Document Server

    Riisager, K.; Borge, M.J.G.; Briz, J.A.; Carmona-Gallardo, M.; Fraile, L.M.; Fynbo, H.O.U.; Giles, T.; Gottberg, A.; Heinz, A.; Johansen, J.G.; Jonson, B.; Kurcewicz, J.; Lund, M.V.; Nilsson, T.; Nyman, G.; Rapisarda, E.; Steier, P.; Tengblad, O.; Thies, R.; Winkler, S.R.

    2014-01-01

    We have observed $\\beta$-delayed proton emission from the neutron-rich nucleus $^{11}$Be by analysing a sample collected at the ISOLDE facility at CERN with accelerator mass spectrometry (AMS). With a branching ratio of (8.4 $\\pm$ 0.6)$\\times$ 10$^{-6}$ the strength of this decay mode, as measured by the B$_\\mathrm{GT}$-value, is unexpectedly high. The result is discussed within a simple single-particle model and could be interpreted as a quasi-free decay of the $^{11}$Be halo neutron into a single-proton state.

  9. Hybrid white organic light-emitting devices consisting of a non-doped thermally activated delayed fluorescent emitter and an ultrathin phosphorescent emitter

    International Nuclear Information System (INIS)

    Zhao, Juan; Wang, Zijun; Wang, Run; Chi, Zhenguo; Yu, Junsheng

    2017-01-01

    Hybrid white organic light-emitting devices (OLEDs) are fabricated by employing non-doped emitting layers (EMLs), which are consisted of a blue thermally activated delayed fluorescent (TADF) emitter 9,9-dimethyl-9,10-dihydroacridine-diphenylsulfone (DMAC-DPS) and an ultrathin yellow iridium complex bis[2-(4-tertbutylphenyl)benzothiazolato-N,C 2′ ] iridium (acetylacetonate) [(tbt) 2 Ir(acac)]. With thickness optimization of DMAC-DPS, a white OLED achieves maximum current efficiency, power efficiency and external quantum efficiency of 34.9 cd/A, 29.2 lm/W and 11.4%, respectively, as well as warm white emission with relatively stable electroluminescence spectra. The results suggest that, bipolar charge carrier transport property and concentration independent property of DMAC-DPS, charge carrier trapping effect of the ultrathin (tbt) 2 Ir(acac), and balanced self-emission process and energy transfer process between DMAC-DPS and (tbt) 2 Ir(acac), contribute to high device performance.

  10. Delayed diagnosis of congenital adrenal hyperplasia with salt wasting due to type II 3beta-hydroxysteroid dehydrogenase deficiency

    DEFF Research Database (Denmark)

    Johannsen, Trine H; Mallet, Delphine; Dige-Petersen, Harriet

    2005-01-01

    Classical 3beta-hydroxysteroid dehydrogenase (3beta-HSD) deficiency is a rare cause of congenital adrenal hyperplasia. We report two sisters presenting with delayed diagnoses of classical 3beta-HSD, despite salt wasting (SW) episodes in infancy. Sibling 1 was referred for premature pubarche, slig...

  11. Nuclear spectroscopy in the rare earth region near the proton drip line

    International Nuclear Information System (INIS)

    Toth, K.S.; Nitschke, J.M.; Wilmarth, P.A.; Vierinen, K.S.

    1989-01-01

    We have used the isotope separator facility OASIS, on-line at the Lawrence Berkeley Laboratory SuperHILAC, to investigate rare earth nuclei close to the proton drip line. Single-particle states near the 82-neutron shell have been examined and their excitation energies determined. Numerous new isotopes, isomers, and β-delayed proton emitters have been discovered. In addition, the α-decay properties of nuclides with N ≥ 84 have been reexamined; this has led to the discovery of several previously unobserved α transitions. The overall experimental program is summarized and some recently obtained results on 145 Dy, 147 Er, 147 Tm, 153 Lu, 155 Lu, and 157 Lu are discussed. 20 refs., 11 figs., 11 tabs

  12. Beta Decay Study of the T{sub z}=−2{sup 56}Zn Nucleus and the Determination of the Half-Lives of a Few fp-shell Nuclei

    Energy Technology Data Exchange (ETDEWEB)

    Rubio, B., E-mail: Berta.Rubio@ific.uv.es [IFIC, CSIC-Universidad de Valencia, E-46071 Valencia (Spain); Orrigo, S.E.A. [IFIC, CSIC-Universidad de Valencia, E-46071 Valencia (Spain); Kucuk, L. [Department of Physics, Istanbul University, Istanbul (Turkey); Montaner-Pizá, A. [IFIC, CSIC-Universidad de Valencia, E-46071 Valencia (Spain); Fujita, Y. [Department of Physics, Osaka University, Toyonaka, Osaka 560-0043 (Japan); RCNP, Osaka University, Ibaraki, Osaka 567-0047 (Japan); Fujita, H. [RCNP, Osaka University, Ibaraki, Osaka 567-0047 (Japan); Blank, B. [CENBG, Université Bordeaux 1, UMR 5797 CNRS/IN2P3, BP 120, F-33175 Gradignan (France); Gelletly, W. [Department of Physics, University of Surrey, Guildford GU2 7XH, Surrey (United Kingdom); Adachi, T. [RCNP, Osaka University, Ibaraki, Osaka 567-0047 (Japan); Agramunt, J.; Algora, A. [IFIC, CSIC-Universidad de Valencia, E-46071 Valencia (Spain); Ascher, P. [CENBG, Université Bordeaux 1, UMR 5797 CNRS/IN2P3, BP 120, F-33175 Gradignan (France); Bilgier, B. [Department of Physics, Istanbul University, Istanbul (Turkey); Cáceres, L. [GANIL, CEA/DSM-CNRS/IN2P3, BP 55027, F-14076 Caen (France); Cakirli, R.B. [Department of Physics, Istanbul University, Istanbul (Turkey); France, G. de [GANIL, CEA/DSM-CNRS/IN2P3, BP 55027, F-14076 Caen (France); Ganioğlu, E. [Department of Physics, Istanbul University, Istanbul (Turkey); Gerbaux, M.; Giovinazzo, J.; Grevy, S. [CENBG, Université Bordeaux 1, UMR 5797 CNRS/IN2P3, BP 120, F-33175 Gradignan (France); and others

    2014-06-15

    This paper concerns the experimental study of the β decay properties of few proton-rich fp-shell nuclei. The nuclei were produced at GANIL in fragmentation reactions, separated with the LISE spectrometer and stopped in an implantation detector surrounded by Ge detectors. The β-delayed gammas, β-delayed protons and the exotic β-delayed gamma-proton emission have been studied. Preliminary results are presented. The decay of the T{sub z}=−2 nucleus {sup 56}Zn has been studied in detail. Information from the β-delayed protons and β-delayed gammas has been used to deduce the decay scheme. The exotic beta-delayed gamma-proton decay has been observed for the first time in the fp-shell. The interpretation of the data was made possible thanks to the detailed knowledge of the mirror Charge Exchange (CE) process and the gamma de-excitation of the states in {sup 56}Co, the mirror nucleus of {sup 56}Cu.

  13. AGS vertical beta function measurements for Run 15

    Energy Technology Data Exchange (ETDEWEB)

    Harper, C. [Brookhaven National Lab. (BNL), Upton, NY (United States); Ahrens, L. [Brookhaven National Lab. (BNL), Upton, NY (United States); Huang, H. [Brookhaven National Lab. (BNL), Upton, NY (United States); Schoefer, V. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2016-10-07

    One key parameter for running the AGS efficiently is by maintaining a low emittance. To measure emittance, one needs to measure the beta function throughout the cycle. This can be done by measuring the beta function at the ionization profile monitors (IPM) in the AGS. This tech note delves into the motivation, the measurement, and some strides that were made throughout Run15.

  14. β-delayed γ-proton decay in 56Zn: Analysis of the charged-particle spectrum

    International Nuclear Information System (INIS)

    Orrigo, S. E.A.; Ascher, P.; Cakirli, R. B.; Kozer, H. C.; Popescu, L.; Rogers, A. M.; Susoy, G.; Suzuki, T.

    2015-01-01

    A study of the β decay of the proton-rich T z = –2 nucleus 56 Zn has been reported in a recent publication. A rare and exotic decay mode, β-delayed γ-proton decay, has been observed there for the first time in the fp shell. Here, we expand on some of the details of the data analysis, focusing on the charged particle spectrum

  15. Hybrid white organic light-emitting devices consisting of a non-doped thermally activated delayed fluorescent emitter and an ultrathin phosphorescent emitter

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Juan [State Key Laboratory of Electronic Thin Film and Integrated Devices, School of Optoelectronic Information, University of Electronic Science and Technology of China, Chengdu 610054 (China); School of Chemistry, Sun Yat-sen University, Guangzhou 510275 (China); Wang, Zijun; Wang, Run [State Key Laboratory of Electronic Thin Film and Integrated Devices, School of Optoelectronic Information, University of Electronic Science and Technology of China, Chengdu 610054 (China); Chi, Zhenguo, E-mail: chizhg@mail.sysu.edu.cn [School of Chemistry, Sun Yat-sen University, Guangzhou 510275 (China); Yu, Junsheng, E-mail: jsyu@uestc.edu.cn [State Key Laboratory of Electronic Thin Film and Integrated Devices, School of Optoelectronic Information, University of Electronic Science and Technology of China, Chengdu 610054 (China)

    2017-04-15

    Hybrid white organic light-emitting devices (OLEDs) are fabricated by employing non-doped emitting layers (EMLs), which are consisted of a blue thermally activated delayed fluorescent (TADF) emitter 9,9-dimethyl-9,10-dihydroacridine-diphenylsulfone (DMAC-DPS) and an ultrathin yellow iridium complex bis[2-(4-tertbutylphenyl)benzothiazolato-N,C{sup 2′}] iridium (acetylacetonate) [(tbt){sub 2}Ir(acac)]. With thickness optimization of DMAC-DPS, a white OLED achieves maximum current efficiency, power efficiency and external quantum efficiency of 34.9 cd/A, 29.2 lm/W and 11.4%, respectively, as well as warm white emission with relatively stable electroluminescence spectra. The results suggest that, bipolar charge carrier transport property and concentration independent property of DMAC-DPS, charge carrier trapping effect of the ultrathin (tbt){sub 2}Ir(acac), and balanced self-emission process and energy transfer process between DMAC-DPS and (tbt){sub 2}Ir(acac), contribute to high device performance.

  16. $\\beta$3$p$-spectroscopy and proton-$\\gamma$ width determination in the decay of $^{31}$Ar

    CERN Multimedia

    We propose to perform a detailed study of the $\\beta$-decay of the dripline nucleus $^{31}$Ar. This will allow a detailed study of the $\\beta$-delayed 3$p$-decay as well as provide important information on the resonances of $^{30}$S and $^{29}$P, in particular the ratio between the $p$- and $\\gamma$- partial widths relevant for astrophysics.

  17. Prolixe-prototype reprocessing unit for irradiating wastes contamined with alpha emitters

    International Nuclear Information System (INIS)

    Madic, C.; Sontag, R.

    1987-01-01

    A large number of hot cells are employed for research on nuclear fuel reprocessing and the production of isotope of transuranium elements. These activities generate solid wastes highly contaminated with alpha, beta, gamma emitters. The Prolixe hot cell was built in order to: 1/ reprocess the solid wastes contaminated with alpha, beta, gamma emitters produced in the Radiochemistry building: 2/ produce package wastes storable in shallow-ground disposal sites: 3/ develop a process sufficiently flexible to make it applicable to waste produced in other installations. The process is based on waste leaching after grinding. Depending on the type of wastes the leaching reactant will have a different composition 1/ nitric acid solution for cellulose waste: 2/ nitric solutions containing Ag(II) for other material. The complete process should achieve: 1/ a high waste volume reduction factor: 2/ the production of immobilized waste packages storage in shallow-ground disposal sites: 3/ the recycling of transuranium elements: 4/ the generation of a minimal volume of effluents. This process can be considered as an alternative process to incineration for the reprocessing of solid wastes highly contaminated with alpha, beta, gamma emitters

  18. BETA SPECTRA. I. Negatrons spectra; ESPECTROS BETA. I. Espectros simples de negatrones

    Energy Technology Data Exchange (ETDEWEB)

    Grau Malonda, A; Garcia-Torano, E

    1978-07-01

    Using the Fermi theory of beta decay, the beta spectra for 62 negatrons emitters have been computed introducing a correction factor for unique forbidden transitions. These spectra are plotted vs. energy, once normal i sed, and tabulated with the related Fermi functions. The average and median energies are calculated. (Author)

  19. Energy Calibration of a Silicon Detector Using Pure Beta-Emitters; Calibracion Energetica de un Detector de Silicio Mediante Emisores Beta Puros

    Energy Technology Data Exchange (ETDEWEB)

    Borras, C; Arcos, J M. los

    1992-07-01

    Energy calibration of SI detectors used in electron spectroscopy 13 commonly performed with conversion electron sources or monoenergetic electrons beams, which are preferred against beta emitters due to the problems arising from their continuous spectra. This paper presents a simple calibration procedure for a PIP-type silicon detector, using 14C, 147Pm, 99{sup T}c and 45Ca sources, that is based on the correspondence between the average channel observed in the experimental spectrum and the mean energy evaluated from the theoretical Fermi distribution for each nuclide. First, a method for evaluating the average channel in the experimental spectrum distorted by the electronic noise is described and its uncertainty estimated. Then, the channel-energy relation ship is established by least squares fitting modified to account for uncertainties in both variables.The calibration has been successfully verified with 147Pm and '09cd sources, showing discrepaneles not greater than 2.5%, within the uncertainties due to the detector resolution and the sources features. (Author)

  20. Energy Calibration of a Silicon Detector Using Pure Beta-Emitters; Calibracion Energetica de un Detector de Silicio Mediante Emisores Beta Puros

    Energy Technology Data Exchange (ETDEWEB)

    Borras, C.; Arcos, J. M. los

    1992-07-01

    Energy calibration of SI detectors used in electron spectroscopy 13 commonly performed with conversion electron sources or monoenergetic electrons beams, which are preferred against beta emitters due to the problems arising from their continuous spectra. This paper presents a simple calibration procedure for a PIP-type silicon detector, using 14C, 147Pm, 99{sup T}c and 45Ca sources, that is based on the correspondence between the average channel observed in the experimental spectrum and the mean energy evaluated from the theoretical Fermi distribution for each nuclide. First, a method for evaluating the average channel in the experimental spectrum distorted by the electronic noise is described and its uncertainty estimated. Then, the channel-energy relation ship is established by least squares fitting modified to account for uncertainties in both variables.The calibration has been successfully verified with 147Pm and '09cd sources, showing discrepaneles not greater than 2.5%, within the uncertainties due to the detector resolution and the sources features. (Author)

  1. Tsub(Z) = 1/2 β-delayed proton precursors. Pt. 2

    International Nuclear Information System (INIS)

    Hardy, J.C.; Faestermann, T.; Schmeing, H.; Macdonald, J.A.; Andrews, H.R.; Geiger, J.S.; Graham, R.L.; Jackson, K.P.

    1981-01-01

    The β-delayed proton decays of 65 Ge (tsub(1/2) = 30.8 +- 1.0 s) and 73 Kr (tsub(1/2) = 28.4 +- 0.7 s) have been studied in detail, proton spectra as well as p-γ and p-X coincidences being obtained. The fraction of 65 Ge β-decays populating proton-emitting states in 65 Ga is measured to be (1.3 +- 0.5) x 10 -4 , and the proton branch in the decay of 73 Kr that populates the first excited state in 72 Se is (18 +- 4)% of the total proton decay. Average γ-widths at 5.5 meV excitation have been established to be 200 +- 60 meV in 65 Ga and 320 +- 60 meV in 73 Br. Values for Qsub(EC)-Bsub(p) are measured to be 2300 +- 100 keV for 65 Ge decay and 3700 +- 150 keV for 73 Kr. The data for both decays have been subjected to statistical model analysis with considerable success. The back-shifted Fermi gas model gives better results for level densities than the Gilbert and Cameron formulas, although important numerical results extracted from the data are shown to be independent of the details of analysis. No evidence is found for local structure in the β-decay strength function. A Jsup(π) assignment of 5/2 + (or possibly 7/2 + ) for 73 Kr gives best agreement with the data. (orig.)

  2. Blood flow measurements in the irradiated pig skin using {beta} emitters radionuclides; Mesure de la circulation sanguine cutanee chez le porc irradie a l`aide de radioisotopes emetteurs {beta}

    Energy Technology Data Exchange (ETDEWEB)

    Daburon, F; Lefaix, J L; Leplat, J J; Fayart, G; Delacroix, D; Le Thanh, P

    1997-01-01

    Non invasive methods of study of the skin blood flow are numerous, but generally do not give any indication on the cutaneous micro-circulatory flow, except for cutaneous laser Doppler. The isotopic exploration of the skin with injected {gamma} radionuclides, even of weak energy, doe snot allow to characterize the skin blood flow, because of the important contribution of the subcutaneous tissues. The use of {beta} emitters energy spectrum, analyzed by different quantitative methods, are proportional to the thickness of the screen localized between the radioactive source and detector. Using simple and complex phantoms composed of tissue equivalent screens, with {sup 32}P sources placed at different depths, it was possible to study the degradation of {beta} spectra, simulating respectively the sub-epidermis and sub-dermis vascular levels. A modelization and an experimental study in-vivo are proposed in this work, with {sup 32}P phosphate administered intravenously in pigs. (author).

  3. A zero-to-few-hundred eV proton beam for calibrations of neutron beta decay experiments

    CERN Document Server

    Naab, F; Zech, W; García, A; Mumm, P

    2002-01-01

    We have constructed a system using a duoplasmatron source to produce a beam of low-energy (0 - few hundred eV) protons with the principal goal of testing and calibrating detectors used to detect protons from neutron beta decay. The system is stable and produces beams by simply turning on the associated power supplies without the need of careful tuning. As an example we show data from calibration of a surface barrier detector in the emiT apparatus. Protons from the system were scattered from an Al target and used to calibrate detectors in the emiT apparatus.

  4. Emittance measurements from the LLUMC proton accelerator

    International Nuclear Information System (INIS)

    Coutrakon, G.; Gillespie, G.H.; Hubbard, J.; Sanders, E.

    2005-01-01

    A new method of calculating beam emittances at the extraction point of a particle accelerator is presented. The technique uses the optimization programs NPSOL and MINOS developed at Stanford University in order to determine the initial values of beam size, divergence and correlation parameters (i.e. beam sigma matrix, σ ij ) that best fit measured beam parameters. These σ ij elements are then used to compute the Twiss parameters α, β, and the phase space area, ε, of the beam at the extraction point. Beam size measurements in X and Y throughout the transport line were input to the optimizer along with the magnetic elements of bends, quads, and drifts. The σ ij parameters were optimized at the accelerator's extraction point by finding the best agreement between these measured beam sizes and those predicted by TRANSPORT. This expands upon a previous study in which a 'trial and error' technique was used instead of the optimizer software, and which yielded similar results. The Particle Beam Optics Laboratory (PBO Lab TM ) program used for this paper integrates particle beam optics and other codes into a single intuitive graphically-based computing environment. This new software provides a seamless interface between the NPSOL and MINOS optimizer and TRANSPORT calculations. The results of these emittance searches are presented here for the eight clinical energies between 70 and 250 MeV currently being used at LLUMC

  5. Few remarks on the absolute counting of {beta} emitters using 4 {pi} counter; Quelques remarques sur la mesure absolue des emetteurs {beta} au compteur 4 {pi}

    Energy Technology Data Exchange (ETDEWEB)

    Grinberg, B; Le Gallic, Y [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    This study looks to determinate the optimum experimental conditions which allow the best accuracy possible for the absolute counting of {beta} emitters when using a 4 {pi} counter. The study has been done with a 4 {pi} counter using source supports of 30 {mu}m thickness. The associated electronic circuit includes: high-voltage, a 1000 scale and a dead time preafier of 4x10{sup -4} {mu}s. In addition, a coincidence preamplifier - with 1 {mu}s resolution time - was added which permits to count the coincidence between the measuring channels. It compares the measurement accuracy and the absorption correction needed for different source supports including polymers thin films with and without metal coating. (M.P.)

  6. Emittance measuring unit for 100% duty factor linac injector beams

    Energy Technology Data Exchange (ETDEWEB)

    Shubaly, M R; Pachner, J Jr; Ormrod, J H; Ungrin, J; Schriber, S O [ed.

    1976-11-01

    A description is given of a system to measure the emittance of a 750 keV 100 mA dc proton beam suitable for injection into a 100% duty factor linear accelerator. A relatively slowly pulsed 45/sup 0/ magnet switches the beam to a beam dump inside the emittance measuring unit for approx. 10 s. A fast pulsed 5/sup 0/ magnet then deflects the beam to a multiple aperture ''pepper-pot'' plate for 300 ..mu..s. Beamlets passing through the plate travel 520 mm and produce a pattern on a scintillator screen. A photograph of the pattern is analyzed to determine beam emittance. Preliminary results on low current beams show a gross increase in the emittance in the horizontal plane.

  7. Measurement of transverse emittance in the Fermilab booster

    Energy Technology Data Exchange (ETDEWEB)

    Graves, William Sproull [Wisconsin U., Madison

    1994-01-01

    A new beam profile monitor has been built and installed in the Fermilab Booster synchrotron. It nondestructively measures the beam's vertical density distribution on a fast turn-by-turn basis. This enables one to measure the beam's transverse emittance and to observe emittance growth as it occurs. For high intensities (>2 times 10^{12 } protons), the normalized 95% emittance was observed to grow from 6pi mm-mrad at injection to 16pi mm-mrad at extraction. The initial (<5 msec) emittance growth and beam losses are shown to be caused by the space charge tune shift onto integer and 1/2 integer resonance lines. The growth near injection accounts for approximately 40% of the observed emittance increase throughout the acceleration cycle. The remaining 60% is due to two factors: slow linear growth due to betatron-motion driven by noise in the rf system; and faster growth after the transition energy that is caused by coupling of the longitudinal beam motion into the transverse planes.

  8. Development of high $\\beta^*$-optics for ALICE

    CERN Document Server

    Hermes, Pascal Dominik; Wessels, Johannes Peter

    This thesis describes a feasibility study for a special optical configuration in Insertion Region 2 (IR2) of the Large Hadron Collider (LHC), which is host of the ALICE detector. This configuration allows the study of elastic and diffractive scattering during LHC high-intensity proton operation, in parallel to the nominal physics studies in all LHC experiments at the design energy of 7 TeV per beam. Such measurements require the instal- lation of additional Roman Pot (RP) detectors in the very forward region, at longitudinal distances of 150 m to 220 m from the Interaction Point (IP). Apart from being adjusted for a specific betatron phase advance between the IP and the RP detectors, such a configuration must be optimized for the largest possible $\\beta^*$ -value, to be sensitive for the smallest possible four-momentum transfer $|t|$. A value of $\\beta^*$ = 18 m is compatible with a bunch spacing of 25 ns, considering the LHC design emittance of N = 3.75 μm rad, and a required bunch-bunch separation of $12 \\...

  9. Measurement of the absolute activity of alpha or beta emitters by measuring product nuclei (daughter) activity increase or by studing its radioactive decay

    International Nuclear Information System (INIS)

    Campos, L.C. de.

    1981-01-01

    A new method for determining absolute activity of alpha or beta emitters by measuring daughter product radioactive decay is presented. The separation method of UX from hexahydrated uranyl nitrate UO 2 (NO 3 ) 2 6H 2 O based on its dissolution in ethyl ether is described and the accuracy of this method is shown. The factors which accuate on total efficiency of a Geiger Mueller detector for beta particles are determined. The possibility to determine the mass of precursor element by daughter nuclei activity is shown. The results are compared with the one obtained by direct measurement of the mass (or number of atoms) of precursor radioactive substance and with theoretical values calculated for isotopes in secular equilibrium. (Author) [pt

  10. MONSTER: a TOF Spectrometer for beta-delayed Neutron Spetroscopy

    CERN Document Server

    Martinez, T; Castilla, J; Garcia, A R; Marin, J; Martinez, G; Mendoza, E; Santos, C; Tera, F; Jordan, M D; Rubio, B; Tain, J L; Bhattacharya, C; Banerjee, K; Bhattacharya, S; Roy, P; Meena, J K; Kundu, S; Mukherjee, G; Ghosh, T K; Rana, T K; Pandey, R; Saxena, A; Behera, B; Penttila, H; Jokinen, A; Rinta-Antila, S; Guerrero, C; Ovejero, M C; Villamarin, D; Agramunt, J; Algora, A

    2014-01-01

    Beta-delayed neutron (DN) data, including emission probabilities, P-n, and energy spectrum, play an important role in our understanding of nuclear structure, nuclear astrophysics and nuclear technologies. A MOdular Neutron time-of-flight SpectromeTER (MONSTER) is being built for the measurement of the neutron energy spectra and branching ratios. The TOF spectrometer will consist of one hundred liquid scintillator cells covering a significant solid angle. The MONSTER design has been optimized by using Monte Carlo (MC) techniques. The response function of the MONSTER cell has been characterized with mono-energetic neutron beams and compared to dedicated MC simulations.

  11. Internal Auger emitters: effects on spermatogenesis and oogenesis in mice

    International Nuclear Information System (INIS)

    Rao, D.V.; Mylavarapu, V.B.; Sastry, K.S.R.; Howell, R.W.

    1988-01-01

    The in vivo biological effects of Auger emitters are investigated using [A] spermatogenesis in mouse testis, and [B] oogenesis in mouse ovary as experimental models. Spermhead survival and induction of abnormal sperm, following intratesticular administration of radiopharmaceuticals, were the end points in Model A. Of interest in Model B is primary oocyte survival after intraperitoneal injection of the radiochemicals. The effectiveness of the Auger emitter is determined relative to its beta emitting companion or external X-rays in the absence of such an analogue. Results reveal pronounced effects of Auger emitters on all end points, not dependent on mode of administration. The efficacy of the Auger emitter is related intimately to its subcellular distribution, which, is governed by the chemical form of the carrier molecule. Conventional dosimetry is inadequate and biophysically meaningful dosimetric approaches are needed to understand in vivo effects of Auger emitters. (author)

  12. Validation the quantification of beta emitters activity in urine by scintillation spectrometry in the liquid phase; Validacion de la cuantificacion de actividad de emisores beta en orina mediante espectrometria de centelleo en fase liquida

    Energy Technology Data Exchange (ETDEWEB)

    Sierra, I.; Hernandez, C.; Benito, P.; Lopez, C.

    2013-07-01

    In this paper the methodology used in the validation of the technique for quantifying activity of some beta emitters in urine ({sup 3}H, {sup 1}4C, {sup 3}5S, {sup 3}2P and {sup 9}0Sr) by scintillation spectrometry Liquid Phase (Liquid Scintillation Counting, LSC) is described in bio elimination Laboratory Service CIEMAT Radiation Dosimetry accredited since last year for carrying out assays measure radiation dose based on ISO forth above. (Author)

  13. Beta-delayed gamma and neutron emission near the double shell closure at 78Ni

    International Nuclear Information System (INIS)

    Rykaczewski, Krzysztof Piotr; Mazzocchi, C.; Grzywacz, R.; Batchelder, J. C.; Bingham, C.R.; Fong, D.; Hamilton, J.H.; Hwang, J.K.; Karny, M.; Krolas, W.; Liddick, S. N.; Morton, A. C.; Mantica, P. F.; Mueller, W. F.; Steiner, M.; Stolz, A.; Winger, J.A.

    2005-01-01

    An experiment was performed at the National Superconducting Cyclotron Laboratory at Michigan State University to investigate β decay of very neutron-rich cobalt isotopes. Beta-delayed neutron emission from 71-74 Co has been observed for the first time. Preliminary results are reported

  14. Beta spectra. II-Positron spectra

    International Nuclear Information System (INIS)

    Grau, A.; Garcia-Torano, E.

    1981-01-01

    Using the Fermi theory of beta decay, the beta spectra for 30 positron emitters have been computed, introducing a correction factor for unique forbidden transitions. The spectra are ploted vs. energy, once normalised, and tabulated with the related Fermi functions. The average and median energies are calculated. (author)

  15. New Beta-delayed Neutron Measurements in the Light-mass Fission Group

    Energy Technology Data Exchange (ETDEWEB)

    Agramunt, J. [Instituto de Física Corpuscular, CSIC-Univ. Valencia, Apdo. Correos 22085, E-46071 Valencia (Spain); García, A.R. [Centro de Investigaciones Energéticas, Medioambientales y Tecnológicas, E-28040 Madrid (Spain); Algora, A. [Instituto de Física Corpuscular, CSIC-Univ. Valencia, Apdo. Correos 22085, E-46071 Valencia (Spain); Äystö, J. [University of Jyväskylä, FI-40014 Jyväskyä (Finland); Caballero-Folch, R.; Calviño, F. [Secció d' Enginyeria Nuclear, Universitat Politécnica de Catalunya, E-08028 Barcelona (Spain); Cano-Ott, D. [Centro de Investigaciones Energéticas, Medioambientales y Tecnológicas, E-28040 Madrid (Spain); Cortés, G. [Secció d' Enginyeria Nuclear, Universitat Politécnica de Catalunya, E-08028 Barcelona (Spain); Domingo-Pardo, C. [Instituto de Física Corpuscular, CSIC-Univ. Valencia, Apdo. Correos 22085, E-46071 Valencia (Spain); Eronen, T. [University of Jyväskylä, FI-40014 Jyväskyä (Finland); Gelletly, W. [Department of Physics, University of Surrey, Guildford GU2 7XH (United Kingdom); Gómez-Hornillos, M.B. [Secció d' Enginyeria Nuclear, Universitat Politécnica de Catalunya, E-08028 Barcelona (Spain); and others

    2014-06-15

    A new accurate determination of beta-delayed neutron emission probabilities from nuclei in the low mass region of the light fission group has been performed. The measurements were carried out using the BELEN 4π neutron counter at the IGISOL-JYFL mass separator in combination with a Penning trap. The new results significantly improve the uncertainties of neutron emission probabilities for {sup 91}Br, {sup 86}As, {sup 85}As, and {sup 85}Ge nuclei.

  16. Generating Low Beta Regions with Quadrupoles for Final Muon Cooling

    Energy Technology Data Exchange (ETDEWEB)

    Acosta, J. G. [Mississippi U.; Cremaldi, L. M. [Mississippi U.; Hart, T. L. [Mississippi U.; Oliveros, S. J. [Mississippi U.; Summers, D. J. [Mississippi U.; Neuffer, D. V. [Fermilab

    2017-05-01

    Muon beams and colliders are rich sources of new physics, if muons can be cooled. A normalized rms transverse muon emittance of 280 microns has been achieved in simulation with short solenoids and a betatron function of 3 cm. Here we use ICOOL, G4beamline, and MAD-X to explore using a 400 MeV/c muon beam and strong focusing quadrupoles to approach a normalized transverse emittance of 100 microns and finish 6D muon cooling. The low beta regions produced by the quadrupoles are occupied by dense, low Z absorbers, such as lithium hydride or beryllium, that cool the beam. Equilibrium transverse emittance is linearly proportional to the beta function. Reverse emittance exchange with septa and/or wedges is then used to decrease transverse emittance from 100 to 25 microns at the expense of longitudinal emittance for a high energy lepton collider. Work remains to be done on chromaticity correction.

  17. Scintillation detector for dosing unknown {beta} emitters deposited on large-surface filters (1963); Detecteur a scintillation pour la dosimetrie d'emetteurs beta inconnus deposes sur filtre de grande surface (1963)

    Energy Technology Data Exchange (ETDEWEB)

    Soudain, G; Cercy, J; Geoffre, B [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1963-07-01

    The apparatus described has been specially studied for direct counting, using a plastic scintillator, of unknown emitters occurring in atmospheric samples collected on large-surface filters (10 cm diameter). In view of the fairly large contribution of low-energy fission products to the overall {beta}-activity of radio-active fallout, the adjustments have been chosen so as to obtain the best yield in an energy range as wide as possible. This has led to the acceptance of a certain background noise which is later reduced by the anti-coincidence method. The quality of the apparatus depends largely on the uniformity of the photocathode in the photomultiplier used. The counter which was built had a counting efficiency for a 10 cm diameter source of 30 per cent for S-35, 88 per cent for P-32, 45 per cent for unknown emitters and a background noise of 56 cpm. (authors) [French] L'appareil decrit a ete specialement etudie pour le comptage direct, a l'aide d'un scintillateur plastique d'emetteurs inconnus recueillis dans les prelevements atmospheriques sur des filtres de grande surface (10 cm de diametre). Etant donne la participation assez importante des produits de fission de faible energie a l'activite globale {beta} des retombees radioactives, les reglages ont ete choisis de maniere a obtenir le meilleur rendement dans une gamme d'energie aussi etendue que possible. Cela a conduit a admettre un certain bruit de fond que l'on reduit ensuite par la methode d'anticoincidence. La qualite de l'appareil depend en grande partie de l'uniformite de la photocathode du photomultiplicateur utilise. Le compteur que l'on a construit possede une efficacite de comptage pour une source de 10 cm de diametre de 30 pour cent pour {sup 35}S, 88 pour cent pour {sup 32}P, 45 pour des emetteurs {beta} inconnus et un bruit de fond de 56 cpm. (auteurs)

  18. BETA SPECTRA. I. Negatrons spectra

    International Nuclear Information System (INIS)

    Grau Malonda, A.; Garcia-Torano, E.

    1978-01-01

    Using the Fermi theory of beta decay, the beta spectra for 62 negatrons emitters have been computed introducing a correction factor for unique forbidden transitions. These spectra are plotted vs. energy, once normal i sed, and tabulated with the related Fermi functions. The average and median energies are calculated. (Author)

  19. Enantioselective rhodium enolate protonations. A new methodology for the synthesis of beta2-amino acids.

    Science.gov (United States)

    Sibi, Mukund P; Tatamidani, Hiroto; Patil, Kalyani

    2005-06-23

    [reaction: see text] Rhodium-catalyzed conjugate addition of an aryl boronic acid to alpha-methylamino acrylates followed by enantioselective protonation of the oxa-pi-allylrhodium intermediate provides access to aryl-substituted beta(2)-amino acids. The impact of the different variables of the reaction on the levels of enantioselectivity has been assessed.

  20. Matrix metalloproteinase inhibition delays wound healing and blocks the latent transforming growth factor-beta1-promoted myofibroblast formation and function

    DEFF Research Database (Denmark)

    Mirastschijski, Ursula; Schnabel, Reinhild; Claes, Juliane

    2010-01-01

    applied topically to full-thickness skin excisional wounds in rats and its ability to inhibit the promotion of myofibroblast formation and function by the latent transforming-growth factor-beta1 (TGF-beta1). BB-94 delayed wound contraction, as well as all other associated aspects of wound healing examined......, including myofibroblast formation, stromal cell proliferation, blood vessel formation, and epithelial wound coverage. Interestingly, BB-94 dramatically increased the level of latent and active MMP-9. The increased levels of active MMP-9 may eventually overcome the ability of BB-94 to inhibit this MMP...... and may explain why wound contraction and other associated events of wound healing were only delayed and not completely inhibited. BB-94 was also found to inhibit the ability of latent TGF-beta1 to promote the formation and function of myofibroblasts. These results suggest that BB-94 could delay wound...

  1. Measuring Beam Sizes and Ultra-Small Electron Emittances Using an X-ray Pinhole Camera.

    Science.gov (United States)

    Elleaume, P; Fortgang, C; Penel, C; Tarazona, E

    1995-09-01

    A very simple pinhole camera set-up has been built to diagnose the electron beam emittance of the ESRF. The pinhole is placed in the air next to an Al window. An image is obtained with a CCD camera imaging a fluorescent screen. The emittance is deduced from the size of the image. The relationship between the measured beam size and the electron beam emittance depends upon the lattice functions alpha, beta and eta, the screen resolution, pinhole size and photon beam divergence. The set-up is capable of measuring emittances as low as 5 pm rad and is presently routinely used as both an electron beam imaging device and an emittance diagnostic.

  2. Emittance Measurement for Beamline Extension at the PET Cyclotron

    Directory of Open Access Journals (Sweden)

    Sae-Hoon Park

    2016-01-01

    Full Text Available Particle-induced X-ray emission is used for determining the elemental composition of materials. This method uses low-energy protons (of several MeV, which can be obtained from high-energy (of tens MeV accelerators. Instead of manufacturing an accelerator for generating the MeV protons, the use of a PET cyclotron has been suggested for designing the beamline for multipurpose applications, especially for the PIXE experiment, which has a dedicated high-energy (of tens MeV accelerator. The beam properties of the cyclotron were determined at this experimental facility by using an external beamline before transferring the ion beam to the experimental chamber. We measured the beam profile and calculated the emittance using the pepper-pot method. The beam profile was measured as the beam current using a wire scanner, and the emittance was measured as the beam distribution at the beam dump using a radiochromic film. We analyzed the measurement results and are planning to use the results obtained in the simulations of external beamline and aligned beamline components. We will consider energy degradation after computing the beamline simulation. The experimental study focused on measuring the emittance from the cyclotron, and the results of this study are presented in this paper.

  3. Formation of short-lived positron emitters in reactions of protons of energies up to 200 MeV with the target elements carbon, nitrogen and oxygen

    CERN Document Server

    Kettern, K; Qaim, S M; Shubin, Yu N; Steyn, G F; Van der Walt, T N; 10.1016/j.apradiso.2004.02.007

    2004-01-01

    Excitation functions were measured by the stacked-foil technique for proton induced reactions on carbon, nitrogen and oxygen leading to the formation of the short-lived positron emitters /sup 11/C (T/sub 1 /2/=20.38 min) and /sup 13/N (T/sub 1/2/=9.96 min). The energy region covered extended up to 200 MeV. The product activity was measured non-destructively via gamma -ray spectrometry. A careful decay curve analysis of the positron annihilation radiation was invariably performed. The experimental results were compared with theoretical data obtained using the modified hybrid nuclear model code ALICE-IPPE for intermediate energies. The agreement was found to be generally satisfactory. The data are of importance in proton therapy.

  4. Emittance growth in coast in the SPS

    CERN Document Server

    Alekou, A; Bartosik, H; Calaga, R

    2017-01-01

    The CERN SPS will be used as a test-bed for the LHCprototype crab-cavities, which will be installed and testedin the SPS in 2018. As the time available for experimen-tal beam dynamics studies with the crab cavities installedin the machine will be limited, a very good preparation isrequired in advance. One of the main concerns is the in-duced emittance growth, driven by phase jitter in the crabcavities. In this respect, several machine development (MD)studies were performed during the past years to quantifyand characterize the emittance evolution of proton beamsin coast in the SPS. In these proceedings, the experimentalobservations from past years are summarized and the MDstudies from 2016 are presented. Finally, a proposal for anexperimental program for 2017 is discussed.

  5. Proton radioactivity lifetimes using Skyrme interactions

    International Nuclear Information System (INIS)

    Routray, T.R.; Tripathy, S.K.; Mishra, Abhishek; Basu, D.N.

    2011-01-01

    The phenomena of proton radioactivity is recent and has been possible with the advent of the radioactive ion beams facilities. The neutron deficient nuclei lying above the proton drip line has positive Q values for protons and are spontaneous proton emitters. This limits the possibilities of the creation of ever more exotic nuclei in the proton rich side of the β stability valley. Limited number of works have been done in calculating the half lives of proton emitting nuclei using different models. But calculation of lifetimes of the proton emitting nuclei using Skyrme interaction has not yet been reported. More than 110 Skyrme sets are available, constructed for different purposes, all having the common feature of giving finite nuclei ground state properties and saturation conditions in nuclear matter. Skyrme sets constructed in the late 90's, particularly the construction of SLy sets and others Skyrme sets developed thereafter, have additional care in constraining the parameters for applications to nuclear matter under extreme conditions. Stone et al. have analyzed the Skyrme sets on the basis of available constraints and have sorted out finally 27 Skyrmes sets which can be admitted for calculation of isospin rich dense nuclear matter. The objective of the work is to examine the predictions of the Skyrme sets on the half lives of the proton emitters

  6. Delayed fission

    Energy Technology Data Exchange (ETDEWEB)

    Hatsukawa, Yuichi [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1997-07-01

    Delayed fission is a nuclear decay process that couples {beta} decay and fission. In the delayed fission process, a parent nucleus undergoes {beta} decay and thereby populates excited states in the daughter. If these states are of energies comparable to or greater than the fission barrier of the daughter, then fission may compete with other decay modes of the excited states in the daughter. In this paper, mechanism and some experiments of the delayed fission will be discussed. (author)

  7. $\\beta$-decay study of neutron-rich Tl and Pb isotopes

    CERN Multimedia

    It is proposed to study the structure of neutron-rich nuclei beyond $^{208}$Pb. The one-proton hole $^{211-215}$Tl and the semi magic $^{213}$Pb will be produced and studied via nuclear and atomic spectroscopy searching for long-lived isomers and investigating the $\\beta$-delayed $\\gamma$- emission to build level schemes. Information on the single particle structure in $^{211-215}$Pb, especially the position of the g$_{9/2}$ and i$_{11/2}$ neutron orbitals, will be extracted along with lifetimes. The $\\beta$-decay will be complemented with the higher spin selectivity that can be obtained by resonant laser ionization to single-out the decay properties of long-living isomers in $^{211,213}$Tl and $^{213}$Pb.

  8. Alpha particle emitters in medicine

    International Nuclear Information System (INIS)

    Fisher, D.R.

    1989-09-01

    Radiation-induced cancer of bone, liver and lung has been a prominent harmful side-effect of medical applications of alpha emitters. In recent years, however, the potential use of antibodies labeled with alpha emitting radionuclides against cancer has seemed promising because alpha particles are highly effective in cell killing. High dose rates at high LET, effectiveness under hypoxic conditions, and minimal expectancy of repair are additional advantages of alpha emitters over antibodies labeled with beta emitting radionuclides for cancer therapy. Cyclotron-produced astatine-211 ( 211 At) and natural bismuth-212 ( 212 Bi) have been proposed and are under extensive study in the United States and Europe. Radium-223 ( 223 Ra) also has favorable properties as a potential alpha emitting label, including a short-lived daughter chain with four alpha emissions. The radiation dosimetry of internal alpha emitters is complex due to nonuniformly distributed sources, short particle tracks, and high relative specific ionization. The variations in dose at the cellular level may be extreme. Alpha-particle radiation dosimetry, therefore, must involve analysis of statistical energy deposition probabilities for cellular level targets. It must also account fully for nonuniform distributions of sources in tissues, source-target geometries, and particle-track physics. 18 refs., 4 figs

  9. Source preparations for alpha and beta measurements

    Energy Technology Data Exchange (ETDEWEB)

    Holm, E. [Risoe National Lab., Roskilde (Denmark)

    2001-01-01

    Regarding alpha particle emitters subject for environmental studies, electrodeposition or co-precipitation as fluorides are the most common methods. For electro deposition stainless steel is generally used as cathode material but also other metals such as Ni, Ag, and Cu showed promising results. The use of other anode material than platinum, such as graphite should be investigated. For other purposes such as optimal resolution other more sophisticated methods are used but often resulting in poorer recovery. For beta particle emitters the type of detection system will decide the source preparation. Similar methods as for alpha particle emitters, electrodeposition or precipitation techniques can be used. Due to the continuous energy distribution of the beta pulse height distribution a high resolution is not required. Thicker sources from the precipitates or a stable isotopic carrier can be accepted but correction for absorption in the source must be done. (au)

  10. $\\beta$-delayed fission, laser spectroscopy and shape-coexistence studies with radioactive At beams

    CERN Multimedia

    We propose to study the $\\beta$-delayed fission, laser spectroscopy and radioactive decay of the newly available pure beams of neutron-deficient and neutron-rich astatine (Z=85) isotopes. The fission probability and the fission fragment distribution of the even-even isotopes $^{194,196}$Po following the $\\beta$-decay of the isotopes $^{194,196}$At will be studied with the Windmill setup. In-source laser spectroscopy will be performed on the entire astatine isotopic chain, using a combination of the Windmill setup, ISOLTRAP MR-ToF and ISOLDE Faraday. Radioactive decay data will be acquired at the Windmill setup throughout those studies and contribute to the global understanding of the phenomenon of shape coexistence in the neutron-deficient lead region.

  11. Interactive session: alpha emitters, fashion or reality? radionuclides and molecules availability

    International Nuclear Information System (INIS)

    Zimmermann, R.

    2015-01-01

    Full text of publication follows. This introduction to the interactive session will simply be based on statements related to the future of therapy in nuclear medicine with some emphasis on the use of alpha-emitters. Some hypotheses will be developed on topics such as 'How will look nuclear medicine in 2025?', 'Do we have enough information to support the use of alpha in therapy?' 'Does it make sense to develop alpha-labelled molecules without long term financial commitment?', 'Will sufficient amounts of radionuclides available when the drugs will be ready for marketing?', 'Do we know enough about alpha emitters toxicity?', 'Is personalized medicine really the solution of the future of health care?', 'How can we convince authorities about the advantages of alpha labelled molecules?', 'Is the development of alpha RIT more expensive or more difficult than beta RIT?', 'Where are all the beta-emitter under development gone?', 'With alpha-emitters, are we speaking about 2025 or 2050?', 'Will Xofigo be a success?', 'What will be the real role of pharmaceutical companies in radiotherapy?', 'Who are the most afraid about radioactivity, the patients or the authorities?'. The speaker will provide his own opinion about each topic. Will you agree or not with him? What is your opinion? (author)

  12. Study of the $\\beta$-delayed Particle Emission of $^{17}$Ne

    CERN Multimedia

    2002-01-01

    We intend to investigate the charged particle decay modes from the excited states of $^{17}$F populated in the $\\beta^+$- decay of $^{17}$Ne. In particular, we propose to study the proton decay branches to $^{16}$O states which are unstable to $\\alpha$- decay. We plan to use the recently developed ISOLDE Si-ball detector array in order to efficiently detect the charged particles in a wide solid angle. We ask for a total of 12 shifts, including 9 shifts for $^{17}$Ne and 3 shifts for stable beam and calibrations. We request the use of a Mg oxide target coupled to a plasma ion source with cooled transfer line or, if possible, to the new MINIMONOECRIS. We would like to make use of the ISOLDE VME DAQ and CERN data storage system.

  13. Suppression of emittance growth caused by mechanical vibrations of magnetic elements in presence of beam-beam effects in the SSC

    International Nuclear Information System (INIS)

    Lebedev, V.A.; Parkhomchuk, V.V.; Shil'tsev, V.D.; Skrinskij, A.N.

    1991-01-01

    A ground motion produces shifts of storage ring quadrupoles. It strongly influences on the beam behaviour in large proton (anti)proton colliders due to the closed orbit distortion and due to the transverse emittance growth. Calculations of both effects are presented in this paper. An active feedback system is useful for the emittance growth suppression. It is shown that in this case the main parameter which determines the emittance growth is the betatron tune spread due to the beam-beam effects. A simple analytical model is considered which results are in good coincidence with computer simulations. All calculations are adapted to the Superconducting Super Collider (SSC). 13 refs.; 9 figs.; 3 tabs

  14. β-delayed p-decay of proton-rich nuclei ^23Al and ^31Cl and explosive H-burning in novae

    Science.gov (United States)

    Trache, L.; Banu, A.; Hardy, J. C.; McCleskey, M.; Simmons, E.; Tabacaru, G.; Tribble, R. E.; Aysto, J.; Jokinen, A.; Saastamoinen, A.; Davinson, T.; Woods, P. J.; Achouri, L.; Roeder, B.

    2008-10-01

    We developed a technique to measure β-delayed proton-decay of proton-rich nuclei produced and separated with MARS at TAMU. In particular, we studied the decay of ^23Al and ^31Cl, both important for understanding explosive H-burning in novae. We have pulsed the beam, implanting the source nuclei moving at about 40 MeV/u in a thin Si strip detector, and then measured β-p and β-γ coincidences simultaneously. The states populated above the proton threshold in ^23Mg and ^31S, respectively, may proton decay. They are resonances in the reaction ^22Na(p,γ)^23Mg (crucial for the depletion of ^22Na in ONe novae) and in ^30P(p,γ)^31S (critical point in explosive H-burning in novae), but the protons emitted have very low energies, starting at about 200 keV, an experimental challenge. The setup and the results are described. The β-decay schemes were established for both nuclei, and IAS identified. The technique has shown a remarkable selectivity to β-delayed charged particle emission and shown to work even at radioactive beam rates of a few pps, for rare isotopes with lifetimes as low as 10s msec.

  15. Non-adiabatic description of proton emission from the odd-odd nucleus 130Eu

    Directory of Open Access Journals (Sweden)

    Patial Monika

    2014-03-01

    Full Text Available We discuss the non-adiabatic quasiparticle approach for calculating the rotational spectra and decay width of odd-odd proton emitters. The Coriolis effects are incorporated in both the parent and daughter wave functions. Results for the two probable ground states (1+ and 2+ of the proton emitter 130Eu are discussed. With our calculations, we confirm the proton emitting state to be the Iπ = 1+ state, irrespective of the strength of the Coriolis interaction. This study provides us with an opportunity to look into the details of wave functions of deformed odd-odd nuclei to which the proton emission halflives are quite sensitive.

  16. Elastic proton-proton scattering at RHIC

    Energy Technology Data Exchange (ETDEWEB)

    Yip, K.

    2011-09-03

    Here we describe elastic proton+proton (p+p) scattering measurements at RHIC in p+p collisions with a special optics run of {beta}* {approx} 21 m at STAR, at the center-of-mass energy {radical}s = 200 GeV during the last week of the RHIC 2009 run. We present preliminary results of single and double spin asymmetries.

  17. Overview of laserwire beam profile and emittance measurements for high power proton accelerators

    CERN Document Server

    Gibson, S M; Bosco, A; Gabor, C; Pozimski, J; Savage, P; Hofmann, T

    2013-01-01

    Laserwires were originally developed to measure micron-sized electron beams via Compton scattering, where traditional wire scanners are at the limit of their resolution. Laserwires have since been applied to larger beamsize, high power H$^-$ ion beams, where the non-invasive method can probe beam densities that would damage traditional diagnostics. While photo-detachment of H$^-$ ions is now routine to measure beam profiles, extending the technique to transverse and longitudinal emittance measurements is a key aim of the laserwire emittance scanner under construction at the Front End Test Stand (FETS) at the RAL. A pulsed, 30 kHz, 8kW peak power laser is fibrecoupled to motorized collimating optics, which controls the position and thickness of the laserwire delivered to the H- interaction chamber. The laserwire slices out a beamlet of neutralized particles, which propagate to a downstream scintillator and camera. The emittance is reconstructed from 2D images as the laserwire position is scanned. Results from ...

  18. Beta/alpha continuous air monitor

    Science.gov (United States)

    Becker, G.K.; Martz, D.E.

    1988-06-27

    A single deep layer silicon detector in combination with a microcomputer, recording both alpha and beta activity and the energy of each pulse, distinquishing energy peaks using a novel curve fitting technique to reduce the natural alpha counts in the energy region where plutonium and other transuranic alpha emitters are present, and using a novel algorithm to strip out radon daughter contribution to actual beta counts. 7 figs.

  19. First Accurate Normalization of the $\\beta$-delayed $\\alpha$ Decay of $^{16}$N and Implications for the $^{12}$C$(\\alpha,\\gamma)^{16}$O Astrophysical Reaction Rate arXiv

    CERN Document Server

    Kirsebom, O.S.; Lica, R.; Munch, M.; Riisager, K.; Fynbo, H.O.U.; Borge, M.J.G.; Madurga, M.; Marroquin, I.; Andreyev, A.N.; Berry, T.A.; Christensen, E.R.; Fernández, P. Díaz; Doherty, D.T.; Van Duppen, P.; Fraile, L.M.; Gallardo, M.C.; Greenlees, P.T.; Harkness-Brennan, L.J.; Hubbard, N.; Huyse, M.; Jensen, J.H.; Johansson, H.; Jonson, B.; Judson, D.S.; Konki, J.; Lazarus, I.; Lund, M.V.; Marginean, N.; Marginean, R.; Perea, A.; Mihai, C.; Negret, A.; Page, R.D.; Pucknell, V.; Rahkila, P.; Sorlin, O.; Sotty, C.; Swartz, J.A.; Sørensen, H.B.; Törnqvist, H.; Vedia, V.; Warr, N.; De Witte, H.

    The $^{12}$C$(\\alpha,\\gamma)^{16}$O reaction plays a central role in astrophysics, but its cross section at energies relevant for astrophysical applications is only poorly constrained by laboratory data. The reduced $\\alpha$ width, $\\gamma_{11}$, of the bound $1^-$ level in $^{16}$O is particularly important to determine the cross section. The magnitude of $\\gamma_{11}$ is determined via sub-Coulomb $\\alpha$-transfer reactions or the $\\beta$-delayed $\\alpha$ decay of $^{16}$N, but the latter approach is presently hampered by the lack of sufficiently precise data on the $\\beta$-decay branching ratios. Here we report improved branching ratios for the bound $1^-$ level and for $\\beta$-delayed $\\alpha$ emission. In the case of the $\\beta$-delayed $\\alpha$ branch, we find a $5\\sigma$ deviation from the literature value. With our new branching ratios, the constraints imposed on $\\gamma_{11}$ by the $\\beta\\alpha$-decay and $\\alpha$-transfer data are of similar precision and, for the first time, in good agreement. Th...

  20. Spectroscopic factor and proton formation probability for the d3/2 proton emitter 151mLu

    Directory of Open Access Journals (Sweden)

    F. Wang

    2017-07-01

    Full Text Available The quenching of the experimental spectroscopic factor for proton emission from the short-lived d3/2 isomeric state in 151mLu was a long-standing problem. In the present work, proton emission from this isomer has been reinvestigated in an experiment at the Accelerator Laboratory of the University of Jyväskylä. The proton-decay energy and half-life of this isomer were measured to be 1295(5 keV and 15.4(8 μs, respectively, in agreement with another recent study. These new experimental data can resolve the discrepancy in the spectroscopic factor calculated using the spherical WKB approximation. Using the R-matrix approach it is found that the proton formation probability indicates no significant hindrance for the proton decay of 151mLu.

  1. Summary Report of Consultants' Meeting on Beta-Delayed Neutron Emission Evaluation

    International Nuclear Information System (INIS)

    Abriola, Daniel; Singh, Balraj; Dillmann, Iris

    2011-12-01

    A summary is given of a Consultants' Meeting assembled to assess the viability of a new IAEA Co-ordinated Research Project (CRP) on Beta-delayed neutron emission evaluation. The current status of the field was reviewed, cases in which new measurements are needed were identified and the current theoretical models were examined. The best known cases were selected as standards and were assessed and preliminary best values of the emission probabilities were obtained. The need of such a CRP was strongly agreed. Both the technical discussions and the expected outcome of such a project are described, along with detailed recommendations for its implementation. (author)

  2. Solar Wind Proton Temperature Anisotropy: Linear Theory and WIND/SWE Observations

    Science.gov (United States)

    Hellinger, P.; Travnicek, P.; Kasper, J. C.; Lazarus, A. J.

    2006-01-01

    We present a comparison between WIND/SWE observations (Kasper et al., 2006) of beta parallel to p and T perpendicular to p/T parallel to p (where beta parallel to p is the proton parallel beta and T perpendicular to p and T parallel to p are the perpendicular and parallel proton are the perpendicular and parallel proton temperatures, respectively; here parallel and perpendicular indicate directions with respect to the ambient magnetic field) and predictions of the Vlasov linear theory. In the slow solar wind, the observed proton temperature anisotropy seems to be constrained by oblique instabilities, by the mirror one and the oblique fire hose, contrary to the results of the linear theory which predicts a dominance of the proton cyclotron instability and the parallel fire hose. The fast solar wind core protons exhibit an anticorrelation between beta parallel to c and T perpendicular to c/T parallel to c (where beta parallel to c is the core proton parallel beta and T perpendicular to c and T parallel to c are the perpendicular and parallel core proton temperatures, respectively) similar to that observed in the HELIOS data (Marsch et al., 2004).

  3. Description of proton radioactivity using the Coulomb and proximity potential model for deformed nuclei

    Science.gov (United States)

    Santhosh, K. P.; Sukumaran, Indu

    2017-09-01

    Half-life predictions have been performed for the proton emitters with Z >50 in the ground state and isomeric state using the Coulomb and proximity potential model for deformed nuclei (CPPMDN). The agreement of the calculated values with the experimental data made it possible to predict some proton emissions that are not verified experimentally yet. For a comparison, the calculations also are performed using other theoretical models, such as the Gamow-like model of Zdeb et al. [Eur. Phys. J. A 52, 323 (2016), 10.1140/epja/i2016-16323-7], the semiempirical relation of Hatsukawa et al. [Phys. Rev. C 42, 674 (1990), 10.1103/PhysRevC.42.674], and the CPPM of Santhosh et al. [Pramana 58, 611 (2002)], 10.1007/s12043-002-0019-2. The Geiger-Nuttall law, originally observed for α decay, studied for proton radioactivity is found to work well provided it is plotted for the isotopes of a given proton emitter nuclide with the same ℓ value. The universal curve is found to be valid for proton radioactivity also as we obtained a single straight line for all proton emissions irrespective of the parents. Through the analysis of the experimentally measured half-lives of 44 proton emitters, the study revealed that the present systematic study lends support to a unified description for studying α decay, cluster radioactivity, and proton radioactivity.

  4. Modeling and analysis of all the positron emitters simulation steps generated during the treatment phase in proton-therapy - from the beam to the PET camera - for the follow-up of the irradiations

    International Nuclear Information System (INIS)

    Ty, C.V.N.

    2012-01-01

    The proton-therapy is an innovative technique for cancer treatment in critical areas, such as the eye or the head. Even though the interaction of protons with human tissues is a well-known physical phenomenon which gives rise to the proton-therapy, there are uncertainties on the proton trajectory due to heterogeneities in the irradiated tissue, the calculation of the beam parameters in the planning treatment affects the theoretical benefits of the protons and the chosen dose delivery process. Thus, methods for irradiation quality control have been suggested. Most of them rely on utilizing the mapping of the positron emitters generated during the irradiation. They are detectable and quantifiable thanks to the use of the PET (positron emitter tomography), a medical imaging technique mainly used for the cancer expansion assessment. PET acquisitions were proposed and then realized on phantoms and patients after proton-therapy. The quality control relies on comparing the measured radioactive distribution to the simulated β + distribution. The modeling of the positron activity generated by protons in the irradiated area can be divided into three steps: the simulation of the proton beam, the modeling of the proton interactions in the irradiated object and the modeling of the PET acquisition. Different ways of simulating these steps are possible. This PhD work suggests different ways of modeling the three steps and evaluates theirs benefits for the irradiation quality control. We have restrained our evaluation to the verification of the proton range and to the uncertainties related to the proton range. This research work utilizes on irradiations in homogenous and inhomogeneous areas in a head model. We have compared the uncertainties on the proton range measured thanks to the following β + distributions: 1) A β + distribution obtained by modeling the irradiation with a proton beam simulated analytically and simulated using the complete Monte Carlo method; 2) A Monte

  5. The differences in delay times for air showers initiated by 100 TeV gamma rays and protons

    International Nuclear Information System (INIS)

    Mikocki, S.; Poirier, J.; Linsley, J.; Consiglio Nazionale delle Ricerche, Palermo; Wrotniak, A.; Maryland Univ., College Park

    1987-01-01

    The purpose of this study is to investigate whether there are any differences in the time delay distributions between showers initiated by gamma rays and by protons. The results of Monte Carlo calculations of atmospheric showers initiated by gamma rays and protons at an energy of 100 TeV show systematic differences. These differences are negligible at small distances from the core of the showers; at larger distances the effects become large. However, at large distances the particle densities are small at an energy of 100 TeV and the subsequent statistical fluctuations would make an identification of gamma-ray showers unreliable. However, these large effects should be included in corrections for the curvature of gamma-ray and proton shower fronts. (author)

  6. Mirror decay of $^{75}$Sr

    CERN Document Server

    Huikari, J; Algora, A; Cederkäll, J; Courtin, S; Dessagne, P; Fraile-Prieto, L M; Franchoo, S; Fynbo, H O U; Huang Wan Xia; Jokinen, A; Knipper, A; Maréchal, F; Miehé, C; Nácher, E; Peräjärvi, K; Poirier, E; Weissman, L; Äystö, J

    2003-01-01

    The beta -decay of /sup 75/Sr to its mirror nucleus /sup 75/Rb was studied at the ISOLDE PSB facility at CERN by means of beta -delayed gamma and proton spectroscopy. The decay Q-value and beta -delayed gamma intensity were measured for the first time. These results, 10.60+or-0.22 MeV and 4.5/sub -0.7//sup +1.9/%, together with accurate measurements of the beta -decay half-life and beta -delayed proton branching ratio yielded the Gamow-Teller strength 0.35+or-0.05 for the mirror transition. Implications of the results on studies of deformation effects and on the path of the rapid proton capture process are discussed. (24 refs).

  7. Asymmetrical field emitter

    Science.gov (United States)

    Fleming, J.G.; Smith, B.K.

    1995-10-10

    A method is disclosed for providing a field emitter with an asymmetrical emitter structure having a very sharp tip in close proximity to its gate. One preferred embodiment of the present invention includes an asymmetrical emitter and a gate. The emitter having a tip and a side is coupled to a substrate. The gate is connected to a step in the substrate. The step has a top surface and a side wall that is substantially parallel to the side of the emitter. The tip of the emitter is in close proximity to the gate. The emitter is at an emitter potential, and the gate is at a gate potential such that with the two potentials at appropriate values, electrons are emitted from the emitter. In one embodiment, the gate is separated from the emitter by an oxide layer, and the emitter is etched anisotropically to form its tip and its asymmetrical structure. 17 figs.

  8. Lower Emittance Lattice for the Advanced Photon Source Upgrade Using Reverse Bending Magnets

    Energy Technology Data Exchange (ETDEWEB)

    Borland, M.; Berenc, T.; Sun, Y.; Sajaev, V.

    2017-06-01

    The Advanced Photon Source (APS) is pursuing an upgrade to the storage ring to a hybrid seven-bend-achromat design [1]. The nominal design provides a natural emittance of 67 pm [2]. By adding reverse dipole fields to several quadrupoles [3, 4] we can reduce the natural emittance to 41 pm while simultaneously providing more optimal beta functions in the insertion devices and increasing the dispersion function at the chromaticity sextupole magnets. The improved emittance results from a combination of increased energy loss per turn and a change in the damping partition. At the same time, the nonlinear dynamics performance is very similar, thanks in part to increased dispersion in the sextupoles. This paper describes the properties, optimization, and performance of the new lattice.

  9. Proton drip-line studies at HRIBF

    International Nuclear Information System (INIS)

    Rykaczewski, K.P.; Batchelder, J.C.; Bingham, C.R.; Bryan, R.E.; Davinson, T.; Woods, P.J.; Ginter, T.N.; Hamilton, J. H.; Gross, C.J.; Grzywacz, R.; Janas, Z.; Karny, M.; MacDonald, B.D.; McConnell, J.W.; Toth, K.S.; Piechaczek, A.; Zganjar, E.F.; Szerypo, J.; Walters, W. B.

    2000-01-01

    Proton radioactivity studies performed at the Holifield Radioactive Ion Beam Facility (HFBR) within the last few years are reviewed. The discovery of five new proton radioactivities 140 Ho, 141m Ho, 145 Tm, 150m Lu and 151m Lu is presented together with a recent observation of fine structure in proton emission from 146gs,m Tm. These proton emitters were produced by means of fusion-evaporation reactions and studied with the HFBR Recoil Mass Separator and detection system based on a Double-sided Silicon Strip Detector. For 113 Cs and 151 Lu, the studies of level structure were extended beyond the proton-emitting states via the measurements with a clover array Clarion using Recoil Decay Tagging

  10. Study of the Beta-Decay Properties of Extremely Proton-Rich Nuclei

    CERN Multimedia

    2002-01-01

    The most proton-rich nuclei known to date have isospin projections $ T _{Z} $ ~=~-3/2, -2 and -5/2. \\\\ \\\\ We propose to carry out a study of their superallowed beta decays, a phenomenon that can only be studied in this region of the nuclear chart. The main aim is to determine the ``effective charge'' in nuclei of the axial vector coupling, the quantity $ ( g'_{A} / g _{A} ) ^{2} $ , which in a recent first experiment on a ~~ $ T _{Z} $~~=~-2 nucleus was determined to be 0.49~$\\pm$~0.05. \\\\ \\\\ Because of the problems connected with the production and acceleration of radioactive ions, our proposal aims at selected elements: neon, argon and rubidium (production runs), magnesium (test and production runs) and calcium (test). Data have so far been taken for $^1

  11. Nearly constant ratio between the proton inertial scale and the spectrum break length scale in the plasma beta range from 0.2 to 1.4 in the solar wind turbulence

    Science.gov (United States)

    Wang, X.; Tu, C. Y.; He, J.; Wang, L.

    2017-12-01

    The spectrum break at the ion scale of the solar wind magnetic fluctuations are considered to give important clue on the turbulence dissipation mechanism. Among several possible mechanisms, the most notable ones are the two mechanisms that related respectively with proton thermal gyro-radius and proton inertial length. However, no definite conclusion has been given for which one is more reasonable because the two parameters have similar values in the normal plasma beta range. Here we do a statistical study for the first time to see if the two mechanism predictions have different dependence on the solar wind velocity and on the plasma beta in the normal plasma beta range in the solar wind at 1 AU. From magnetic measurements by Wind, Ulysses and Messenger, we select 60 data sets with duration longer than 8 hours. We found that the ratio between the proton inertial scale and the spectrum break scale do not change considerably with both varying the solar wind speed from 300km/s to 800km/s and varying the plasma beta from 0.2 to 1.4. The average value of the ratio times 2pi is 0.46 ± 0.08. However, the ratio between the proton gyro-radius and the break scale changes clearly. This new result shows that the proton inertial scale could be a single factor that determines the break length scale and hence gives a strong evidence to support the dissipation mechanism related to it in the normal plasma beta range. The value of the constant ratio may relate with the dissipation mechanism, but it needs further theoretical study to give detailed explanation.

  12. Shape-coexistence and shape-evolution studies for bismuth isotopes by insource laser spectroscopy and $\\beta$-delayed fission in $^{188}$Bi

    CERN Multimedia

    The proposal aims at the two main goals: \\\\ \\\\1) the studies of shape-coexistence and shape-evolution phenomena in the long chain of bismuth isotopes (Z=83) by in-source laser spectroscopy measurements of isotopic shifts (IS) and hyperfine structures (hfs), and \\\\ 2) $\\beta$-delayed fission ($\\beta$DF) of two isomeric states in $^{188}$Bi. \\\\ \\\\Isomer-selective $\\beta$DF studies for $^{188m1, 188m2}$Bi isomers will enable us for the first time to investigate the spin-dependence of the $\\beta$DF process and to check theoretical predictions of asymmetrical fission fragment mass-distribution in this region of nuclei. The measurements will be performed with the well-proven Windmill and MR-TOF MS/Penning Trap techniques.

  13. $\\beta$-delayed neutron spectroscopy of $^{130-132}$ Cd isotopes with the ISOLDE decay station and the VANDLE array

    CERN Multimedia

    We propose to use the new ISOLDE decay station and the neutron detector VANDLE to measure the $\\beta$-delayed neutron emission of N=82-84 $^{130-132}$Cd isotopes. The large delayed neutron emission probability observed in a previous ISOLDE measurement is indicative of the Gamow-Teller transitions due to the decay of deep core neutrons. Core Gamow-Teller decay has been experimentally proven in the $^{78}$Ni region for the N>50 nuclei using the VANDLE array. The spectroscopic measurement of delayed neutron emission along the cadmium isotopic chain will allow us to track the evolution of the single particle states and the shell gap.

  14. Experimental and theoretical study of two-proton and proton-deuteron correlations at very small relative momenta

    International Nuclear Information System (INIS)

    Martin, Lilian

    1993-01-01

    In this research thesis, the author first reports the analysis of light particle correlations by two theoretical approaches. The first one is the classical approximation of correlations: formulation, characteristics of the emitter nucleus and initial conditions, construction of the correlation function with notably the comparison with experimental proton-proton and proton-deuteron correlation functions measured in the 40 Ar + 108 Ag at 44 MeV/nucleon. The second one is the quantum approach of correlations: formulations, predictions of the quantum model with the same comparison as above. The second part addresses the measurement and analysis of the proton-proton correlation function at very small relative momenta: presentation of the studied reaction, description of the experiment (sensors, magnetic spectrometer, event recording), analysis of protons detected within the spectrometer) [fr

  15. Study on design of proton linacs

    International Nuclear Information System (INIS)

    Yu Qingchang

    2000-01-01

    Two important directions in the development of proton linacs are high-current proton linacs (mainly applied in nuclear power field) and compact proton linacs (for proton therapy). There are some common characteristics in them: (1) Employment of the novel accelerating structures, which are combination and evolution of the conventional ones; (2) Accelerating beam with small emittance; (3) Requirement for high reliability. The construction of the former is, however, much more difficult because it still needs low beam lose rate and as high power transformation efficiency as possible. Some important problems in the design of these accelerators are discussed and some schemes designed are presented

  16. Highly efficient exciplex organic light-emitting diodes using thermally activated delayed fluorescent emitters as donor and acceptor materials

    Science.gov (United States)

    Jeon, Sang Kyu; Yook, Kyoung Soo; Lee, Jun Yeob

    2016-06-01

    Highly efficient exciplex type organic light-emitting diodes were developed using thermally activated delayed fluorescent emitters as donors and acceptors of an exciplex. Blue emitting bis[4-(9,9-dimethyl-9,10-dihydroacridine)phenyl]sulfone (DMAC-DPS) was a donor and 9,9‧-(5-(4,6-diphenyl-1,3,5-triazin-2-yl)-1,3-phenylene)bis(9H-carbazole) (DDCzTrz) and 9,9‧,9″-(5-(4,6-diphenyl-1,3,5-triazin-2-yl)benzene-1,2,3-triyl)tris(9H-carbazole) (TCzTrz) were acceptor materials. The exciplexes of DMAC-DPS:TCzTrz and DMAC-DPS:DDCzTrz resulted in high photoluminescence quantum yield and high quantum efficiency in the green exciplex organic light-emitting diodes. High quantum efficiencies of 13.4% and 15.3% were obtained in the DMAC-DPS:DDCzTrz and DMAC-DPS:TCzTrz exciplex devices.

  17. Preliminary results of an in-beam PET prototype for proton therapy

    Energy Technology Data Exchange (ETDEWEB)

    Attanasi, F.; Belcari, N.; Camarda, M. [Department of Physics, University of Pisa and INFN Sezione di Pisa, Pisa (Italy); Cirrone, G.A.P.; Cuttone, G. [INFN Laboratori Nazionali del Sud, Catania (Italy); Del Guerra, A. [Department of Physics, University of Pisa and INFN Sezione di Pisa, Pisa (Italy); Di Rosa, F. [INFN Laboratori Nazionali del Sud, Catania (Italy); Lanconelli, N. [Department of Physics, University of Bologna and INFN Sezione di Bologna, Bologna (Italy); Rosso, V. [Department of Physics, University of Pisa and INFN Sezione di Pisa, Pisa (Italy)], E-mail: valeria.rosso@pi.infn.it; Russo, G. [INFN Laboratori Nazionali del Sud, Catania (Italy); Vecchio, S. [Department of Physics, University of Pisa and INFN Sezione di Pisa, Pisa (Italy)

    2008-06-11

    Proton therapy can overcome the limitations of conventional radiotherapy due to the more selective energy deposition in depth and to the increased biological effectiveness. Verification of the delivered dose is desirable, but the complete stopping of the protons in patient prevents the application of electronic portal imaging methods that are used in conventional radiotherapy During proton therapy {beta}{sup +} emitters like {sup 11}C, {sup 15}O, {sup 10}C are generated in irradiated tissues by nuclear reactions. The measurement of the spatial distribution of this activity, immediately after patient irradiation, can lead to information on the effective delivered dose. First, results of a feasibility study of an in-beam PET for proton therapy are reported. The prototype is based on two planar heads with an active area of about 5x5 cm{sup 2}. Each head is made up of a position sensitive photomultiplier coupled to a square matrix of same size of LYSO scintillating crystals (2x2x18 mm{sup 3} pixel dimensions). Four signals from each head are acquired through a dedicated electronic board that performs signal amplification and digitization. A 3D reconstruction of the activity distribution is calculated using an expectation maximization algorithm. To characterize the PET prototype, the detection efficiency and the spatial resolution were measured using a point-like radioactive source. The validation of the prototype was performed using 62 MeV protons at the CATANA beam line of INFN LNS and PMMA phantoms. Using the full energy proton beam and various range shifters, a good correlation between the position of the activity distal edge and the thickness of the beam range shifter was found along the axial direction.

  18. Magnetic resonance imaging and proton magnetic resonance spectroscopy of the brain in the diagnostic evaluation of developmental delay

    NARCIS (Netherlands)

    Verbruggen, Krijn T.; Meiners, Linda C.; Sijens, Paul E.; Lunsing, Roelineke J.; van Spronsen, Francjan J.; Brouwer, Oebele F.

    Aim: To assess the contribution of MRI and proton spectroscopy (1HMRS) in establishing an etiological diagnosis in children with developmental delay (DD) and to assess whether the chance of finding specific abnormalities correlates with the presence of neurological signs and/or abnormal head

  19. Linac4 45 keV Proton Beam Measurements

    CERN Document Server

    Bellodi, G; Hein, L M; Lallement, J-B; Lombardi, A M; Midttun, O; Scrivens, R; Posocco, P A

    2013-01-01

    Linac4 is a 160 MeV normal-conducting H- linear accelerator, which will replace the 50 MeV proton Linac2 as injector for the CERN proton complex. Commissioning of the low energy part - comprising the H - source, a 45 keV Low Energy Beam Transport line (LEBT), a 3 MeV Radiofrequency Quadrupole (RFQ) and a Medium Energy Beam Transport (MEBT) - will start in fall 2012 on a dedicated test stand installation. In preparation to this, preliminary measurements were taken using a 45 keV proton source and a temporary LEBT setup, with the aim of characterising the output beam by comparison with the predictions of simulations. At the same time this allowed a first verification of the functionalities of diagnostics instrumentation and acquisition software tools. Measurements of beam profile, emittance and intensity were taken in three different setups: right after the source, after the first and after the second LEBT solenoids respectively. Particle distributions were reconstructed from emittance scan...

  20. Cancer therapy with alpha-emitters labeled peptides.

    Science.gov (United States)

    Dadachova, Ekaterina

    2010-05-01

    Actively targeted alpha-particles offer specific tumor cell killing action with less collateral damage to surrounding normal tissues than beta-emitters. During the last decade, radiolabeled peptides that bind to different receptors on the tumors have been investigated as potential therapeutic agents both in the preclinical and clinical settings. Advantages of radiolabeled peptides over antibodies include relatively straightforward chemical synthesis, versatility, easier radiolabeling, rapid clearance from the circulation, faster penetration and more uniform distribution into tissues, and less immunogenicity. Rapid internalization of the radiolabeled peptides with equally rapid re-expression of the cell surface target is a highly desirable property that enhances the total delivery of these radionuclides into malignant sites. Peptides, such as octreotide, alpha-melanocyte-stimulating hormone analogues, arginine-glycine-aspartic acid-containing peptides, bombesin derivatives, and others may all be feasible for use with alpha-emitters. The on-going preclinical work has primarily concentrated on octreotide and octreotate analogues labeled with Bismuth-213 and Astatine-211. In addition, alpha-melanocyte-stimulating hormone analogue has been labeled with Lead-212/Bismuth-212 in vivo generator and demonstrated the encouraging therapeutic efficacy in treatment of experimental melanoma. Obstacles that continue to obstruct widespread acceptance of alpha-emitter-labeled peptides are primarily the supply of these radionuclides and concerns about potential kidney toxicity. New sources and methods for production of these medically valuable radionuclides and better understanding of mechanisms related to the peptide renal uptake and clearance should speed up the introduction of alpha-emitter-labeled peptides into the clinic. Copyright 2010 Elsevier Inc. All rights reserved.

  1. Energy measurement and longitudinal beam emittance reconstruction in L4T line

    CERN Document Server

    Meng, C; Garoby, R; Lallement, JB; Lombardi, A; Tang, J Y; Yarmohammadi Satri, M; CERN. Geneva. ATS Department

    2013-01-01

    LINAC4 is a new linear accelerator for H- ion which will replace proton Linac2 as injector for the CERN proton accelerator complex. LINAC4 accelerates H− ions from 45 keV to 160 MeV in a sequence of normal conducting structures. Then, H- ions with a kinetic energy of 160 MeV will be sent to the PS Booster. This note describes two energy measurement methods and a improved method that will be used for longitudinal emittance reconstruction with space charge by multi-particle tracking code and the expected results.

  2. Study of the Nuclear Structure of 39P Using Beta-Delayed Gamma Spectroscopy

    Science.gov (United States)

    Abromeit, Brittany; NSCL Experiment E14063 Team Team

    2016-03-01

    Investigation of nuclei with neutron and proton imbalance is at the forefront of nuclear physics research today. This is driven by the fact that the structure in these regimes may vary with that seen near the valley of stability. With eight neutrons more than the stable isotope of phosphorous, 39P is a neutron-rich exotic nucleus that has very limited information on it: previous studies of 39P produce only three known energy levels and gamma rays. The fragmentation of a 48Ca primary beam on a 564mg/cm2 thick Be target at the National Superconducting Cyclotron Laboratory (NSCL) was used to produce exotic 39Si. Using the NSCL Beta Counting System (BCS), consisting of a thick planner germanium double-sided strip detector (GeDSSD) and 16 High-purity germanium detectors in an array, SeGA, the beta-gamma coincidences from the decay of 39Si to 39P were analyzed. The resulting level scheme of 39P, including over 12 new gamma rays and energy states, confirmation of the previously measured half-life, and first-time logft values will be presented. This work was supported by the NSF under Grant No. 1401574.

  3. Semi-empirical model to determine pure β--emitters in closed waste packages using Bremsstrahlung radiation

    International Nuclear Information System (INIS)

    Takacs, S.; Hermanne, A.

    2001-01-01

    Medical establishments and research laboratories use many different type of radionuclides for diagnostic, therapeutic and research purposes. As a final by product large amount of medical waste are produced. This waste represents both biological and radiation hazards, therefore it requires special treatments in both point of view. Biomedical waste is usually best managed on site by decay storage, with minimal transport risk and ALARA (as low as reasonably achieved) exposure levels. The nuclear medical waste has characteristics fundamentally different from the nuclear fuel cycle waste. In medical practice radioactive material is used both in sealed and unsealed form, but major part of the medical waste is produced by using unsealed isotopes of relatively short half-life in most cases less than 100 days and of low specific activity. There are gamma-emitter, position-emitter and pure beta-knitter among these isotopes. The positron-emitter isotopes have usually less than 2 hours half-life; therefore they do not contribute too much to the volume of the radioactive waste since they decay rapidly. Among the γ- and pure β - - emitters there are isotopes with half-life from seconds to several hundred days. Waste containing isotopes with longer half-life contributes mainly to that large volume of waste produced regularly at biomedical sites. On site decay storage requires accurate determination of activity levels. Since quantitative estimation of isotope activity can be difficult where waste packages contain a mixed combination of β - -γ-emitters, segregation at the time of waste production is essential. Accurate identification and quantitative measurement of γ-emitter isotopes is possible with a large volume, reverse electrode, high purity germanium detector even those cases when the isotope emits only low energy gamma photons. However, there is problem with the pure β - emitting isotopes to measure. In biological health care and pharmaceutical research a range of

  4. Beam dynamics studies and emittance optimization in the CTF3 linac at CERN

    CERN Document Server

    Urschütz, Peter; Corsini, Roberto; Döbert, Steffen; Ferrari, Arnaud; Tecker, Frank

    2006-01-01

    Small transverse beam emittances and well-known lattice functions are crucial for the 30 GHz power production in the Power Extraction and Transfer Structure (PETS) and for the commissioning of the Delay Loop of the CLIC Test Facility 3 (CTF3). Following beam dynamics simulation results, two additional solenoids were installed in the CTF3 injector in order to improve the emittance. During the runs in 2005 and 2006, an intensive measurement campaign to determine Twiss parameters and beam sizes was launched. The results obtained by means of quadrupole scans for different modes of operation suggest emittances well below the nominal .n,rms = 100 ?Î?Êm and a good agreement with PARMELA simulations.

  5. Relaxation dynamics of a quantum emitter resonantly coupled to a metal nanoparticle

    DEFF Research Database (Denmark)

    Nerkararyan, K. V.; Bozhevolnyi, S. I.

    2014-01-01

    consequence of this relaxation process is that the emission, being largely determined by the MNP, comes out with a substantial delay. A large number of system parameters in our analytical description opens new possibilities for controlling quantum emitter dynamics. (C) 2014 Optical Society of America......The presence of a metal nanoparticle (MNP) near a quantum dipole emitter, when a localized surface plasmon mode is excited via the resonant coupling with an excited quantum dipole, dramatically changes the relaxation dynamics: an exponential decay changes to step-like behavior. The main physical...

  6. MetroBeta: Beta Spectrometry with Metallic Magnetic Calorimeters in the Framework of the European Program of Ionizing Radiation Metrology

    Science.gov (United States)

    Loidl, M.; Beyer, J.; Bockhorn, L.; Enss, C.; Györi, D.; Kempf, S.; Kossert, K.; Mariam, R.; Nähle, O.; Paulsen, M.; Rodrigues, M.; Schmidt, M.

    2018-05-01

    MetroBeta is a European project aiming at the improvement of the knowledge of the shapes of beta spectra, both in terms of theoretical calculations and measurements. It is part of a common European program of ionizing radiation metrology. Metallic magnetic calorimeters (MMCs) with the beta emitter embedded in the absorber have in the past proven to be among the best beta spectrometers, in particular for low-energy beta transitions. Within this project, new designs of MMCs optimized for five different beta energy ranges were developed. A new detector module with thermal decoupling of MMC and SQUID chips was designed. An important aspect of the research and development concerns the source/absorber preparation techniques. Four beta spectra with maximum energies ranging from 76 to 709 keV will be measured. Improved theoretical calculation methods and complementary measurement techniques complete the project.

  7. Proton Radioactivity Measurements at HRIBF: Ho, Lu, and Tm Isotopes

    International Nuclear Information System (INIS)

    Akovali, Y.; Batchelder, J.C.; Bingham, C.R.; Davinson, T.; Ginter, T.N.; Gross, C.J.; Grzywacz, R.; Hamilton, J.H.; Janas, Z.; Karny, M.; Kim, S.H.; MacDonald, B.D.; Mas, J.F.; McConnell, J.W.; Piechaczek, A.; Ressler, J.J.; Rykaczewski, K.; Slinger, R.C.; Szerypo, J.; Toth, K.S.; Weintraub, W.; Woods, P.J.; Yu, C.-H.; Zganjar, E.F.

    1998-01-01

    Two new isotopes, 145 Tm and 140 Ho and three isomers in previously known isotopes, 141m Ho, 150m Lu and 151m Lu have been discovered and studied via their decay by proton emission. These proton emitters were produced at the Holifield Radioactive Ion Beam Facility (HRIBF) by heavy-ion fusion-evaporation reactions, separated in A/Q with a recoil mass spectrometer (RMS), and detected in a double-sided silicon strip detector (DSSD). The decay energy and half-life was measured for each new emitter. An analysis in terms of a spherical shell model is applied to the Tm and Lu nuclei, but Ho is considerably deformed and requires a collective model interpretation

  8. On evaluated nuclear data for beta-delayed gamma rays following of special nuclear materials

    Energy Technology Data Exchange (ETDEWEB)

    Mencarini, Leonardo de H.; Caldeira, Alexandre D., E-mail: mencarini@ieav.cta.b, E-mail: alexdc@ieav.cta.b [Instituto de Estudos Avancados (IEAv/CTA), Sao Jose dos Campos, SP (Brazil)

    2011-07-01

    In this paper, a new type of information available in ENDF is discussed. During a consistency check of the evaluated nuclear data library ENDF/B-VII.0 performed at the Nuclear Data Subdivision of the Institute for Advanced Studies, the size of the files for some materials drew the attention of one of the authors. Almost 94 % of all available information for these special nuclear materials is used to represent the beta-delayed gamma rays following fission. This is the first time this information is included in an ENDF version. (author)

  9. On evaluated nuclear data for beta-delayed gamma rays following of special nuclear materials

    International Nuclear Information System (INIS)

    Mencarini, Leonardo de H.; Caldeira, Alexandre D.

    2011-01-01

    In this paper, a new type of information available in ENDF is discussed. During a consistency check of the evaluated nuclear data library ENDF/B-VII.0 performed at the Nuclear Data Subdivision of the Institute for Advanced Studies, the size of the files for some materials drew the attention of one of the authors. Almost 94 % of all available information for these special nuclear materials is used to represent the beta-delayed gamma rays following fission. This is the first time this information is included in an ENDF version. (author)

  10. Noninterceptive transverse emittance measurements using BPM for Chinese ADS R&D project

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Zhi-Jun, E-mail: wangzj@impcas.ac.cn [Institute of Modern Physics, The Chinese Academy of Sciences, Lanzhou 73000 (China); Feng, Chi [Institute of Modern Physics, The Chinese Academy of Sciences, Lanzhou 73000 (China); He, Yuan, E-mail: hey@impcas.ac.cn [Institute of Modern Physics, The Chinese Academy of Sciences, Lanzhou 73000 (China); Dou, Weiping [Institute of Modern Physics, The Chinese Academy of Sciences, Lanzhou 73000 (China); Tao, Yue; Chen, Wei-long [Institute of Modern Physics, The Chinese Academy of Sciences, Lanzhou 73000 (China); University of the Chinese Academy of Sciences, Beijing 100049 (China); Jia, Huan; Liu, Shu-hui; Wang, Wang-sheng; Zhang, Yong; Wu, Jian-qiang; Zhang, Sheng-hu; Zhang, X.L. [Institute of Modern Physics, The Chinese Academy of Sciences, Lanzhou 73000 (China)

    2016-04-21

    The noninterceptive four-dimensional transverse emittance measurements are essential for commissioning the high power continue-wave (CW) proton linacs as well as their operations. The conventional emittance measuring devices such as slits and wire scanners are not well suited under these conditions due to sure beam damages. Therefore, the method of using noninterceptive Beam Position Monitor (BPM) is developed and demonstrated on Injector Scheme II at the Chinese Accelerator Driven Sub-critical System (China-ADS) proofing facility inside Institute of Modern Physics (IMP) [1]. The results of measurements are in good agreements with wire scanners and slits at low duty-factor pulsed (LDFP) beam. In this paper, the detailed experiment designs, data analysis and result benchmarking are presented.

  11. Application of activity pencil beam algorithm using measured distribution data of positron emitter nuclei for therapeutic SOBP proton beam

    International Nuclear Information System (INIS)

    Miyatake, Aya; Nishio, Teiji

    2013-01-01

    Purpose: Recently, much research on imaging the clinical proton-irradiated volume using positron emitter nuclei based on target nuclear fragment reaction has been carried out. The purpose of this study is to develop an activity pencil beam (APB) algorithm for a simulation system for proton-activated positron-emitting imaging in clinical proton therapy using spread-out Bragg peak (SOBP) beams.Methods: The target nuclei of activity distribution calculations are 12 C nuclei, 16 O nuclei, and 40 Ca nuclei, which are the main elements in a human body. Depth activity distributions with SOBP beam irradiations were obtained from the material information of ridge filter (RF) and depth activity distributions of compounds of the three target nuclei measured by BOLPs-RGp (beam ON-LINE PET system mounted on a rotating gantry port) with mono-energetic Bragg peak (MONO) beam irradiations. The calculated data of depth activity distributions with SOBP beam irradiations were sorted in terms of kind of nucleus, energy of proton beam, SOBP width, and thickness of fine degrader (FD), which were verified. The calculated depth activity distributions with SOBP beam irradiations were compared with the measured ones. APB kernels were made from the calculated depth activity distributions with SOBP beam irradiations to construct a simulation system using the APB algorithm for SOBP beams.Results: The depth activity distributions were prepared using the material information of RF and the measured depth activity distributions with MONO beam irradiations for clinical therapy using SOBP beams. With the SOBP width widening, the distal fall-offs of depth activity distributions and the difference from the depth dose distributions were large. The shapes of the calculated depth activity distributions nearly agreed with those of the measured ones upon comparison between the two. The APB kernels of SOBP beams were prepared by making use of the data on depth activity distributions with SOBP beam

  12. Low emittance optics of photon factory storage ring at KEK

    International Nuclear Information System (INIS)

    Kamiya, Y.; Katoh, M.; Honjo, I.; Araki, A.; Kihara, M.

    1987-01-01

    A new optics is being successfully tested at the Photon Factory Storage Ring (PF-RING) in order to reduce the emittance to 0.13 mm mrad, about one third of the present value. This optics with four additional quadrupole magnets is a modified version of one of the optics designed as an option at the early period of PF construction. One advantage of this new optics is that the beta-function at RF-sections is smaller than that of the old option. The other advantage is that the dispersion function is zero at the long straight sections for insertion devices and RF cavities. The aim of this paper is to describe the new low-emittance optics as well as the parameters of the new quadrupole magnets and power supplies. Some preliminary results of machine study are also presented

  13. Nuclear spectroscopy of very proton rich nuclei through HI induced reactions; the 14s high spin isomer in /sup 95/Pd

    CERN Document Server

    Nolte, E; Geier, R; Gui, S Z; Heim, U; Hick, H; Komninos, P; Korschinek, G; Kubik, P; Morinaga, H; Schollmeier, W

    1981-01-01

    /sup 40/Ca, /sup 58/Ni and /sup 60/Ni beams from the Munich tandem and the Munich heavy ion postaccelerator have been used to produce very proton rich nuclei in the N=50 N=82 regions. The residual nuclei have been studied with the help of gamma and particle spectroscopy. The level schemes of /sup 95/Rh, /sup 146/Dy and /sup 150/Er and the beta -decay schemes, /sup 95/Pd/sup m/ to /sup 95/Rh, /sup 144/Tb to /sup 144/Gd, /sup 146/Ho to /sup 146/Dy to /sup 146/Tb to /sup 146/Gd, /sup 148/Er to /sup 148/Ho to /sup 148/Dy and /sup 150/Tm to /sup 150/Er to /sup 150/Dy have been investigated. beta delayed proton emission from a J/sup pi / approximately=21/sup +/ isomeric state in /sup 95/Pd has been observed. (12 refs).

  14. Low-emittance Storage Rings

    CERN Document Server

    Wolski, Andrzej

    2014-01-01

    The effects of synchrotron radiation on particle motion in storage rings are discussed. In the absence of radiation, particle motion is symplectic, and the beam emittances are conserved. The inclusion of radiation effects in a classical approximation leads to emittance damping: expressions for the damping times are derived. Then, it is shown that quantum radiation effects lead to excitation of the beam emittances. General expressions for the equilibrium longitudinal and horizontal (natural) emittances are derived. The impact of lattice design on the natural emittance is discussed, with particular attention to the special cases of FODO-, achromat- and theoretical-minimum-emittance-style lattices. Finally, the effects of betatron coupling and vertical dispersion (generated by magnet alignment and lattice tuning errors) on the vertical emittance are considered.

  15. submitter Proton therapy treatment monitoring with the DoPET system: activity range, positron emitters evaluation and comparison with Monte Carlo predictions

    CERN Document Server

    Muraro, S; Belcari, N; Bisogni, M G; Camarlinghi, N; Cristoforetti, L; Guerra, A Del; Ferrari, A; Fracchiolla, F; Morrocchi, M; Righetto, R; Sala, P; Schwarz, M; Sportelli, G; Topi, A; Rosso, V

    2017-01-01

    Ion beam irradiations can deliver conformal dose distributions minimizing damage to healthy tissues thanks to their characteristic dose profiles. Nevertheless, the location of the Bragg peak can be affected by different sources of range uncertainties: a critical issue is the treatment verification. During the treatment delivery, nuclear interactions between the ions and the irradiated tissues generate β+ emitters: the detection of this activity signal can be used to perform the treatment monitoring if an expected activity distribution is available for comparison. Monte Carlo (MC) codes are widely used in the particle therapy community to evaluate the radiation transport and interaction with matter. In this work, FLUKA MC code was used to simulate the experimental conditions of irradiations performed at the Proton Therapy Center in Trento (IT). Several mono-energetic pencil beams were delivered on phantoms mimicking human tissues. The activity signals were acquired with a PET system (DoPET) based on two plana...

  16. Alpha/beta pulse shape discrimination in plastic scintillation using commercial scintillation detectors

    International Nuclear Information System (INIS)

    Bagan, H.; Tarancon, A.; Rauret, G.; Garcia, J.F.

    2010-01-01

    Activity determination in different types of samples is a current need in many different fields. Simultaneously analysing alpha and beta emitters is now a routine option when using liquid scintillation (LS) and pulse shape discrimination. However, LS has an important drawback, the generation of mixed waste. Recently, several studies have shown the capability of plastic scintillation (PS) as an alternative to LS, but no research has been carried out to determine its capability for alpha/beta discrimination. The objective of this study was to evaluate the capability of PS to discriminate alpha/beta emitters on the basis of pulse shape analysis (PSA). The results obtained show that PS pulses had lower energy than LS pulses. As a consequence, a lower detection efficiency, a shift to lower energies and a better discrimination of beta and a worst discrimination of alpha disintegrations was observed for PS. Colour quenching also produced a decrease in the energy of the particles, as well as the effects described above. It is clear that in PS, the discrimination capability was correlated with the energy of the particles detected. Taking into account the discrimination capabilities of PS, a protocol for the measurement and the calculation of alpha and beta activities in mixtures using PS and commercial scintillation detectors has been proposed. The new protocol was applied to the quantification of spiked river water samples containing a pair of radionuclides ( 3 H- 241 Am or 90 Sr/ 90 Y- 241 Am) in different activity proportions. The relative errors in all determinations were lower than 7%. These results demonstrate the capability of PS to discriminate alpha/beta emitters on the basis of pulse shape and to quantify mixtures without generating mixed waste.

  17. Half-lives of ground and isomeric states in {sup 97}Cd and the astrophysical origin of {sup 96}Ru

    Energy Technology Data Exchange (ETDEWEB)

    Lorusso, G., E-mail: lorusso@ribf.riken.j [National Superconducting Cyclotron Laboratory, Michigan State University, East Lansing, MI 48824 (United States); Joint Institute for Nuclear Astrophysics, Michigan State University, East Lansing, MI 48824 (United States); Department of Physics and Astronomy, Michigan State University, East Lansing, MI 48824 (United States); Becerril, A.; Amthor, A. [National Superconducting Cyclotron Laboratory, Michigan State University, East Lansing, MI 48824 (United States); Joint Institute for Nuclear Astrophysics, Michigan State University, East Lansing, MI 48824 (United States); Department of Physics and Astronomy, Michigan State University, East Lansing, MI 48824 (United States); Baumann, T.; Bazin, D. [National Superconducting Cyclotron Laboratory, Michigan State University, East Lansing, MI 48824 (United States); Berryman, J.S. [National Superconducting Cyclotron Laboratory, Michigan State University, East Lansing, MI 48824 (United States); Department of Chemistry, Michigan State University, East Lansing, MI 48824 (United States); Brown, B.A. [National Superconducting Cyclotron Laboratory, Michigan State University, East Lansing, MI 48824 (United States); Joint Institute for Nuclear Astrophysics, Michigan State University, East Lansing, MI 48824 (United States); Department of Physics and Astronomy, Michigan State University, East Lansing, MI 48824 (United States); Cyburt, R.H. [National Superconducting Cyclotron Laboratory, Michigan State University, East Lansing, MI 48824 (United States); Joint Institute for Nuclear Astrophysics, Michigan State University, East Lansing, MI 48824 (United States); Crawford, H.L. [National Superconducting Cyclotron Laboratory, Michigan State University, East Lansing, MI 48824 (United States); Department of Chemistry, Michigan State University, East Lansing, MI 48824 (United States)

    2011-05-09

    First experimental evidence for a high-spin isomer (25/2{sup +}) in {sup 97}Cd, a waiting point in the astrophysical rapid proton capture process, is presented. The data were obtained in {beta}-decay studies at NSCL using the new RF Fragment Separator system and detecting {beta}-delayed protons and {beta}-delayed {gamma} rays. Decays from ground and isomeric states were disentangled, and proton emission branches were determined for the first time. We find half-lives of 1.10(8) s and 3.8(2) s, and {beta}-delayed proton emission branches of 12(2)% and 25(4)% were deduced for the ground and isomeric states, respectively. With these results, the nuclear data needed to determine an rp-process contribution to the unknown origin of solar {sup 96}Ru are in place. When the new data are included in astrophysical rp-process calculations, one finds that an rp-process origin of {sup 96}Ru is unlikely.

  18. Direct-current proton-beam measurements at Los Alamos

    International Nuclear Information System (INIS)

    Sherman, J.; Stevens, R.R.; Schneider, J.D.; Zaugg, T.

    1994-01-01

    Recently, a CW proton accelerator complex was moved from Chalk River Laboratories (CRL) to Los Alamos National Laboratory. This includes a 50-keV dc proton injector with a single-solenoid low-energy beam transport system (LEBT) and a CW 1.25-MeV, 267-MHz radiofrequency quadrupole (RFQ). The move was completed after CRL had achieved 55-mA CW operation at 1.25 MeV using 250-kW klystrode tubes to power the RFQ. These accelerator components are prototypes for the front end of a CW linac required for an accelerator-driven transmutation linac, and they provide early confirmation of some CW accelerator components. The injector (ion source and LEBT) and emittance measuring unit are installed and operational at Los Alamos. The dc microwave ion source has been operated routinely at 50-keV, 75-mA hydrogen-ion current. This ion source has demonstrated very good discharge and H 2 gas efficiencies, and sufficient reliability to complete CW RFQ measurements at CRL. Proton fraction of 75% has been measured with 550-W discharge power. This high proton fraction removes the need for an analyzing magnet. Proton LEBT emittance measurements completed at Los Alamos suggest that improved transmission through the RFQ may be achieved by increasing the solenoid focusing current. Status of the final CW RFQ operation at CRL and the installation of the RFQ at Los Alamos is given

  19. Rare Earth Garnet Selective Emitter

    Science.gov (United States)

    Lowe, Roland A.; Chubb, Donald L.; Farmer, Serene C.; Good, Brian S.

    1994-01-01

    Thin film Ho-YAG and Er-YAG emitters with a platinum substrate exhibit high spectral emittance in the emission band (epsilon(sub lambda) approx. = 0.75, sup 4)|(sub 15/2) - (sup 4)|(sub 13/2),for Er-YAG and epsilon(sub lambda) approx. = 0.65, (sup 5)|(sub 7) - (sup 5)|(sub 8) for Ho-YAG) at 1500 K. In addition, low out-of-band spectral emittance, epsilon(sub lambda) less than 0.2, suggest these materials would be excellent candidates for high efficiency selective emitters in thermophotovoltaic (TPV) systems operating at moderate temperatures (1200-1500 K). Spectral emittance measurements of the thin films were made (1.2 less than lambda less than 3.0 microns) and compared to the theoretical emittances calculated using measured values of the spectral extinction coefficient. In this paper we present the results for a new class of rare earth ion selective emitters. These emitters are thin sections (less than 1 mm) of yttrium aluminum garnet (YAG) single crystal with a rare earth substitutional impurity. Selective emitters in the near IR are of special interest for thermophotovoltaic (TPV) energy conversion. The most promising solid selective emitters for use in a TPV system are rare earth oxides. Early spectral emittance work on rare earth oxides showed strong emission bands in the infrared (0.9 - 3 microns). However, the emittance outside the emission band was also significant and the efficiency of these emitters was low. Recent improvements in efficiency have been made with emitters fabricated from fine (5 - 10 microns) rare earth oxide fibers similar to the Welsbach mantle used in gas lanterns. However, the rare earth garnet emitters are more rugged than the mantle type emitters. A thin film selective emitter on a low emissivity substrate such as gold, platinum etc., is rugged and easily adapted to a wide variety of thermal sources. The garnet structure and its many subgroups have been successfully used as hosts for rare earth ions, introduced as substitutional

  20. Proton-conducting beta"-alumina via microwave-assisted synthesis and mechanism of enhanced corrosion prevention of a zinc rich coating with electronic control

    Science.gov (United States)

    Kirby, Brent William

    Proton Conducting beta-alumina via Microwave Assisted Synthesis. The microwave assisted synthesis of proton conducting Mg- and Li-stabilized NH4+/H3O+ beta-alumina from a solution based gel precursor is reported. beta-alumina is a ceramic fast ion conductor containing two-dimensional sheets of mobile cations. Na +-beta-alumina is the most stable at the sintering temperatures (1740°C) reached in a modified microwave oven, and can be ion exchanged to the K+ form and then to the NH4+/H 3O+ form. beta-phase impurity is found to be 20% for Mg-stabilized material and 30-40% for Li-stabilized material. The composition of the proton conducting form produced here is deficient in NH4 + as compared to the target composition (NH4)1.00 (H3O)0.67Mg0.67Al10.33O 17. Average grain conductivity for Li-stabilized material at 150°C is 6.6x10-3 +/- 1.6x10-3 S/cm with 0.29 +/- 0.05 eV activation energy, in agreement with single crystal studies in the literature. Grain boundary conductivity is found to be higher in the Li-stabilized material. A hydrogen bond energy hypothesis is presented to explain these differences. Li-stabilized NH4+/H3O + beta-alumina is demonstrated as a fuel cell electrolyte, producing 28 muA/cm2 of electrical current at 0.5 V. Mechanism of Enhanced Corrosion Prevention of a Zinc Rich Coating with Electronic Control. A corrosion inhibition system consisting of high weight-loading zinc rich coating applied to steel panels is examined. An electronic control unit (ECU) consisting of a battery and a large capacitor in series with the panel is shown to improve corrosion protection upon immersion in 3% NaCl solution. Weekly solution changes to avoid zinc saturation in solution system were necessary to see well differentiated results. The corrosion product, hydrozincite [Zn5(CO3) 2(OH)6] is observed to deposit within the pores of the coating and on the surface as a barrier layer. Simonkolleite [Zn5(OH) 8Cl2·H2O] is found to form in place of the original zinc particles

  1. Modeling the effects of repeated systemic administrations of small activity amounts In radionuclide therapy with beta emitters

    International Nuclear Information System (INIS)

    Calderon, Carlos; Gonzalez, Joaquin; Cepero, Janet; Colom, Camila; Rodriguez, Juan C.

    2008-01-01

    Full text: Good results for radionuclide therapy treatments where repeated short time spaced systemic injection of small activity amounts are given have been reported. Bone marrow and kidneys are usually considered as dose-limiting organs in radionuclide therapy. The treatments in radionuclide therapy with repeated administration could be optimized if irradiation effects in those one might be estimated. Xeno-grafted mice is the often biological model used during the evaluation of candidates for radionuclide therapy. A mathematical model of tumor cell kinetics was combined with another one reported for marrow cell kinetics which allows the calculation of marrow cell survival and proliferation in response to different irradiation schemes. Radionuclide therapy treatment with repeated administrations with radiopharmaceuticals labeled with beta emitters were simulated. The effects on fast-growing and slow-growing tumors were evaluated, as well as radiosensitive and radioresistant tumors. For more realistic estimation of absorbed dose in mice organs the cross-irradiation due to high energy beta particles was included into the MIRD's formula. Tumor and kidneys responses to the irradiation were estimated on the linear-quadratic model framework which was adapted for a multi-exponential dose rate function describing radionuclide therapy treatments with repeated administrations. Published values for murine tumors kinetics, marrows cellular turnover rates and radiosensitivities were used during the calculations. Iso-effective schemes were also determined varying the interval between fractions and the number of administration. For a given tolerated level of thrombocytopenia and absorbed dose in kidneys an optimal regime of radionuclide therapy with repeated administration could be found. The mathematical model presented here allows the prediction of the nadir and duration of thrombocytopenia, the effects on kidneys and the tumor cell response to various treatment schemes

  2. The electric potential of particles in interstellar space released from a nuclear waste payload

    Science.gov (United States)

    Williams, A. C.

    1980-01-01

    Mechanisms for charging a grain in the interplanetary medium include: (1) capture of solar wind electrons; (2) capture of solar wind protons; (3) ejection of electrons through the photoelectric effect due to the solar radiation; (4) escape of beta particles from beta emitters in the grain; and (5) escape of alpha particles from alpha emitters in the grain. The potentials on both nonradioactive and radioactive grains are considered with relation to particle size and time, and the distance from the Sun. Numerical results are presented where the waste mix is assumed to be PW-4b.

  3. Measurement of the proton recoil spectrum in neutron beta decay with the spectrometer aSPECT. Study of systematic effects

    Energy Technology Data Exchange (ETDEWEB)

    Konrad, Gertrud Emilie

    2012-01-24

    Free neutron decay, n{yields}pe anti {nu}{sub e}, is the simplest nuclear beta decay, well described as a purely left-handed, vector minus axial-vector interaction within the framework of the Standard Model (SM) of elementary particles and fields. Due to its highly precise theoretical description, neutron beta decay data can be used to test certain extensions to the SM. Possible extensions require, e.g., new symmetry concepts like left-right symmetry, new particles, leptoquarks, supersymmetry, or the like. Precision measurements of observables in neutron beta decay address important open questions of particle physics and cosmology, and are generally complementary to direct searches for new physics beyond the SM in high-energy physics. In this doctoral thesis, a measurement of the proton recoil spectrum with the neutron decay spectrometer aSPECT is described. From the proton spectrum the antineutrinoelectron angular correlation coefficient a can be derived. In our first beam time at the Forschungs-Neutronenquelle Heinz Maier-Leibnitz in Munich, Germany (2005-2006), background instabilities due to particle trapping and the electronic noise level of the proton detector prevented us from presenting a new value for a. In the latest beam time at the Institut Laue-Langevin (ILL) in Grenoble, France (2007-2008), the trapped particle background has been reduced sufficiently and the electronic noise problem has essentially been solved. For the first time, a silicon drift detector was used. As a result of the data analysis, we identified and fixed a problem in the detector electronics which caused a significant systematic error. The target figure of the latest beam time was a new value for a with a total relative error well below the present literature value of 4 %. A statistical accuracy of about 1.4% was reached, but we could only set upper limits on the correction of the problem in the detector electronics, which are too high to determine a meaningful result. The present

  4. Measurement of the proton recoil spectrum in neutron beta decay with the spectrometer aSPECT. Study of systematic effects

    International Nuclear Information System (INIS)

    Konrad, Gertrud Emilie

    2012-01-01

    Free neutron decay, n→pe anti ν e , is the simplest nuclear beta decay, well described as a purely left-handed, vector minus axial-vector interaction within the framework of the Standard Model (SM) of elementary particles and fields. Due to its highly precise theoretical description, neutron beta decay data can be used to test certain extensions to the SM. Possible extensions require, e.g., new symmetry concepts like left-right symmetry, new particles, leptoquarks, supersymmetry, or the like. Precision measurements of observables in neutron beta decay address important open questions of particle physics and cosmology, and are generally complementary to direct searches for new physics beyond the SM in high-energy physics. In this doctoral thesis, a measurement of the proton recoil spectrum with the neutron decay spectrometer aSPECT is described. From the proton spectrum the antineutrinoelectron angular correlation coefficient a can be derived. In our first beam time at the Forschungs-Neutronenquelle Heinz Maier-Leibnitz in Munich, Germany (2005-2006), background instabilities due to particle trapping and the electronic noise level of the proton detector prevented us from presenting a new value for a. In the latest beam time at the Institut Laue-Langevin (ILL) in Grenoble, France (2007-2008), the trapped particle background has been reduced sufficiently and the electronic noise problem has essentially been solved. For the first time, a silicon drift detector was used. As a result of the data analysis, we identified and fixed a problem in the detector electronics which caused a significant systematic error. The target figure of the latest beam time was a new value for a with a total relative error well below the present literature value of 4 %. A statistical accuracy of about 1.4% was reached, but we could only set upper limits on the correction of the problem in the detector electronics, which are too high to determine a meaningful result. The present doctoral

  5. Response of a multi-element dosimeter to calibrated beta sources with E/sub max/ from 0.23 to 3.5 MeV

    International Nuclear Information System (INIS)

    Endres, G.W.R.; Scherpelz, R.I.; Roberson, P.L.

    1982-06-01

    The responses of several different dosimeter absorber systems were studied to determine their usefulness in beta radiation fields. Exposures to several different beta emitters were conducted at the PNL Calibrations Laboratory. The sources used are: 147 Pm, 85 Kr, U(nat), 90 Sr- 90 Y, and 106 Ru- 106 Rh. The maximum energy of these beta emitters varies from 0.23 to 3.5 MeV. The beta sources are calibrated for absorbed dose to tissue at a depth of 0.007 cm. Measurements of response for 4, 5, and 7 element versions of the dosimeter were made. All data reported were obtained from sets of three TLDs exposed under each absorber and for each of the radiation sources

  6. In-beam spectroscopy study of the proton emitter 151Lu

    International Nuclear Information System (INIS)

    Yu, C.; Rykaczewski, K.; Toth, K.S.; Akovali, Y.; Baktash, C.; Galindo-Uribarri, A.; Gross, C.J.; Paul, S.D.; Radford, D.C.; Batchelder, J.C.; Gross, C.J.; Bingham, C.R.; Grzywacz, R.; Kim, S.H.; Weintraub, W.; Ginter, T.N.; Grzywacz, R.; Rykaczewski, K.; Karny, M.; MacDonald, B.D.; Szerypo, J.

    1998-01-01

    Gamma rays decaying from the excited states of the proton-unbound 151 Lu were observed for the first time in an experiment using the 96 Ru( 58 Ni,p2n) 151 Lu reaction. These γ rays were identified by correlating prompt γ radiations at the target position with 151 Lu proton radioactivities at the focal plane of a recoil mass separator. Systematic data on N=80 isotones suggest a possible isomeric level at high spin in 151 Lu. Our measurement was unable to observe such an isomer, but provided an upper limit on its half-life. The observed γ rays in 151 Lu can be interpreted in terms of two possible level structures. copyright 1998 The American Physical Society

  7. Summary Report of 1st Research Coordination Meeting on Development of Reference Database for Beta-delayed Neutron Emission

    International Nuclear Information System (INIS)

    Dillmann, Iris; Dimitriou, Paraskevi; Singh, Balraj

    2014-03-01

    A summary is given of the 1st Research Coordination Meeting of the new IAEA Coordinated Research Project (CRP) on Development of a Reference Database for Beta-delayed neutron emission data. Participants presented their work, reviewed the current status of the field with regards to individual precursors and aggregate data, and discussed the scope of the work to be undertaken. A list of priorities and task assignments was produced. (author)

  8. Status report on a dc 130-mA, 75-keV proton injector

    International Nuclear Information System (INIS)

    Sherman, J.; Arvin, A.; Hodgkins, D.

    1997-01-01

    A 110-mA, 75-keV dc proton injector is being developed at Los Alamos. We use a microwave proton source coupled to a two solenoid, space-charge neutralized, low-energy beam transport (LEBT) system. The ion source produces 110-mA proton current at 75 keV using 600 - 800 W of 2.45 GHz input discharge power. Typical proton fraction is 85-90% of the total extracted ion current, and the rms normalized beam emittance after transport through a prototype 2.1 m LEBT is 0.20 (πmm-mrad). Beam space-charge neutralization is measured to be > 98% which enables the solenoid magnetic transport to successfully match the injector beam into a radio-frequency quadrupole (RFQ). Beam simulations indicate small emittance growth in the proposed 2.8 m low-energy demonstration accelerator (LEDA) LEBT. The LEBT also contains beam diagnostics, steering, and a beam deflector for variable duty factor and accelerator fast protect functions. The injector computer controls and reliability status are also discussed

  9. A detection system for charged-particle decay studies with a continuous-implantation method

    Energy Technology Data Exchange (ETDEWEB)

    Sun, L.J. [China Institute of Atomic Energy, Beijing 102413 (China); Xu, X.X., E-mail: xuxinxing@ciae.ac.cn [China Institute of Atomic Energy, Beijing 102413 (China); Lin, C.J., E-mail: cjlin@ciae.ac.cn [China Institute of Atomic Energy, Beijing 102413 (China); Wang, J.S. [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); Fang, D.Q. [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China); Li, Z.H. [School of Physic and State Key Laboratory of Nuclear Physics and Technology, Peking University, Beijing 100871 (China); Wang, Y.T. [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China); Li, J. [School of Physic and State Key Laboratory of Nuclear Physics and Technology, Peking University, Beijing 100871 (China); Yang, L.; Ma, N.R. [China Institute of Atomic Energy, Beijing 102413 (China); Wang, K. [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China); Zang, H.L. [School of Physic and State Key Laboratory of Nuclear Physics and Technology, Peking University, Beijing 100871 (China); Wang, H.W.; Li, C.; Shi, C.Z.; Nie, M.W.; Li, X.F.; Li, H. [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800 (China); Ma, J.B.; Ma, P. [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); and others

    2015-12-21

    A new detection system with high detection efficiency and low detection threshold has been developed for charged-particle decay studies, including β-delayed proton, α decay or direct proton emission from proton-rich nuclei. The performance was evaluated by using the β-delayed proton emitter {sup 24}Si produced by projectile fragmentation at the First Radioactive Ion Beam Line in Lanzhou. Under a continuous-beam mode, the isotopes of interest were implanted into two double-sided silicon strip detectors, where the subsequent decays were measured and correlated to the preceding implantations by using position and time information. The system allows us to measure protons with energies down to about 200 keV without obvious β background in the proton spectrum. Further application of the detection system can be extended to the measurements of β-delayed proton decay and the direct proton emission of more exotic proton-rich nuclei.

  10. Emittance measurements for optimum operation of the J-PARC RF-driven H{sup −} ion source

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, A., E-mail: akira.ueno@j-parc.jp; Ohkoshi, K.; Ikegami, K.; Takagi, A.; Yamazaki, S.; Oguri, H. [J-PARC Center, Tokai-mura, Naka-gun, Ibaraki-ken 319-1195 (Japan)

    2015-04-08

    In order to satisfy the Japan Proton Accelerator Research Complex (J-PARC) second stage requirements of an H{sup −} ion beam of 60mA within normalized emittances of 1.5πmm•mrad both horizontally and vertically, a flat top beam duty factor of 1.25% (500μs×25Hz) and a life-time of longer than 1month, the J-PARC cesiated RF-driven H{sup −} ion source was developed by using an internal-antenna developed at the Spallation Neutron Source (SNS). The transverse emittances of the source were measured with various conditions to find out the optimum operation conditions minimizing the horizontal and vertical rms normalized emittances. The transverse emittances were most effectively reduced by operating the source with the plasma electrode temperature lower than 70°C. The optimum value of the cesium (Cs) density around the beam hole of the plasma electrode seems to be proportional to the plasma electrode temperature. The fine control of the Cs density is indispensable, since the emittances seem to increase proportionally to the excessiveness of the Cs density. Furthermore, the source should be operated with the Cs density beyond a threshold value, since the plasma meniscus shape and the ellipse parameters of the transverse emittances seem to be changed step-function-likely on the threshold Cs value.

  11. Calculation of the detection efficiency in liquid scintillators. I.- Single negatrons emitters; Calculo de la eficiencia de deteccion en liquidos centelleadores. I. Nucleidos que se desintegran por emision simple de negatrones

    Energy Technology Data Exchange (ETDEWEB)

    Grau Malonda, A.; Garcia-torano, E.

    1981-07-01

    Counting efficiency for 62 single beta emitters has been computed from the beta energy distribution, the figure of merit and the ionization quenching. Efficiency v.s. figure of merit is plotted and tabulated. (Author) 16 refs.

  12. Development of a pepper-pot emittance meter for diagnostics of low-energy multiply charged heavy ion beams extracted from an ECR ion source

    Energy Technology Data Exchange (ETDEWEB)

    Nagatomo, T., E-mail: nagatomo@riken.jp; Kase, M.; Kamigaito, O.; Nakagawa, T. [Nishina Center for Accelerator Based Science, RIKEN, Wako, Saitama 351-0198 (Japan); Tzoganis, V. [Nishina Center for Accelerator Based Science, RIKEN, Wako, Saitama 351-0198 (Japan); Cockcroft Institute, Daresbury, Warrington WA4 4AD (United Kingdom); Department of Physics, University of Liverpool, Liverpool, Merseyside L69 3BX (United Kingdom)

    2016-02-15

    Several fluorescent materials were tested for use in the imaging screen of a pepper-pot emittance meter that is suitable for investigating the beam dynamics of multiply charged heavy ions extracted from an ECR ion source. SiO{sub 2} (quartz), KBr, Eu-doped CaF{sub 2}, and Tl-doped CsI crystals were first irradiated with 6.52-keV protons to determine the effects of radiation damage on their fluorescence emission properties. For such a low-energy proton beam, only the quartz was found to be a suitable fluorescent material, since the other materials suffered a decay in fluorescence intensity with irradiation time. Subsequently, quartz was irradiated with heavy {sup 12}C{sup 4+}, {sup 16}O{sup 4+}, and {sup 40}Ar{sup 11+} ions, but it was found that the fluorescence intensity decreased too rapidly to measure the emittance of these heavy-ion beams. These results suggest that a different energy loss mechanism occurs for heavier ions and for protons.

  13. Quenching-free fluorescence signal from plastic-fibres in proton dosimetry: understanding the influence of Čerenkov radiation

    DEFF Research Database (Denmark)

    Christensen, Jeppe Brage; Almhagen, Erik; Nyström, Håkan

    2018-01-01

    The origin of photons emitted in optical fibres under proton irradiation has been attributed to either entirely Čerenkov radiation or light consisting of fluorescence with a substantial amount of Čerenkov radiation. The source of the light emission is assessed in order to understand why the signal...... from optical fibres irradiated with protons is reportedly quenching-free. The present study uses the directional emittance of Čerenkov photons in 12 MeV and 20 MeV electron beams to validate a Monte Carlo model for simulating the emittance and transmission of Čerenkov radiation in optical fibres. We...

  14. Efficiency enhancements for MCP-based beta autoradiography imaging

    CERN Document Server

    Lees, J E

    2002-01-01

    We describe three approaches to increase the beta detection efficiency of microchannel plate detectors for biological beta autoradiography:(a)reversing the microchannel plate (MCP) bias polarity, changing the conventional high negative voltage on the input MCP to a grounded input, (b) a reduction in MCP pore size from 12.5 to 6 mu m, (c) using a CsI coating as an efficient secondary electron emitter. We also present our first measurements of double-tracer ( sup 3 H and sup 1 sup 4 C) imaging using pulse height analysis to distinguish between isotopes.

  15. Total absorption γ -ray spectroscopy of the β -delayed neutron emitters Br87 , Br88 , and Rb94

    Energy Technology Data Exchange (ETDEWEB)

    Valencia, E.; Tain, J. L.; Algora, A.; Agramunt, J.; Estevez, E.; Jordan, M. D.; Rubio, B.; Rice, S.; Regan, P.; Gelletly, W.; Podolyák, Z.; Bowry, M.; Mason, P.; Farrelly, G. F.; Zakari-Issoufou, A.; Fallot, M.; Porta, A.; Bui, V. M.; Rissanen, J.; Eronen, T.; Moore, I.; Penttilä, H.; Äystö, J.; Elomaa, V. -V.; Hakala, J.; Jokinen, A.; Kolhinen, V. S.; Reponen, M.; Sonnenschein, V.; Cano-Ott, D.; Garcia, A. R.; Martínez, T.; Mendoza, E.; Caballero-Folch, R.; Gomez-Hornillos, B.; Gorlichev, V.; Kondev, F. G.; Sonzogni, A. A.; Batist, L.

    2017-02-01

    We investigate the decay of Br-87,Br-88 and Rb-94 using total absorption gamma-ray spectroscopy. These important fission products are beta-delayed neutron emitters. Our data show considerable beta gamma intensity, so far unobserved in high-resolution gamma-ray spectroscopy, from states at high excitation energy. We also find significant differences with the beta intensity that can be deduced from existing measurements of the beta spectrum. We evaluate the impact of the present data on reactor decay heat using summation calculations. Although the effect is relatively small it helps to reduce the discrepancy between calculations and integral measurements of the photon component for U-235 fission at cooling times in the range 1-100 s. We also use summation calculations to evaluate the impact of present data on reactor antineutrino spectra. We find a significant effect at antineutrino energies in the range of 5 to 9 MeV. In addition, we observe an unexpected strong probability for. emission from neutron unbound states populated in the daughter nucleus. The. branching is compared to Hauser-Feshbach calculations, which allow one to explain the large value for bromine isotopes as due to nuclear structure. However the branching for Rb-94, although much smaller, hints of the need to increase the radiative width gamma by one order of magnitude. This increase in gamma would lead to a similar increase in the calculated (n, gamma) cross section for this very neutron-rich nucleus with a potential impact on r process abundance calculations.

  16. Nuclear Science Division annual report, July 1, 1981-September 30, 1982

    Energy Technology Data Exchange (ETDEWEB)

    Mahoney, J. (ed.)

    1983-06-01

    This report summarizes the scientific research carried out within the Nuclear Science Division between July 1, 1981, and September 30, 1982. Heavy-ion investigations continue to dominate the experimental and theoretical research efforts. Complementary programs in light-ion nuclear science, in nuclear data evaluation, and in the development of advanced instrumentation are also carried out. Results from Bevalac experiments employing a wide variety of heavy ion beams, along with new or upgraded detector facilities (HISS, the Plastic Ball, and the streamer chamber) are contained in this report. These relativistic experiments have shed important light on the degree of equilibration for central collisions, the time evolution of a nuclear collision, the nuclear density and compressional energy of these collisions, and strange particle production. Reaction mechanism work dominates the heavy-ion research at the 88-Inch Cyclotron and the SuperHILAC. Recent experiments have contributed to our understanding of the nature of light-particle emission in deep-inelastic collisions, of peripheral reactions, incomplete fusion, fission, and evaporation. Nuclear structure investigations at these accelerators continue to be directed toward the understanding of the behavior of nuclei at high angular momentum. Research in the area of exotic nuclei has led to the observation at the 88-Inch Cyclotron of the ..beta..-delayed proton decay of odd-odd T/sub z/ = -2 nuclides; ..beta..-delayed proton emitters in the rare earth region are being investigated at the SuperHILAC.

  17. Final Report for DUSEL R&D: BetaCage: A Screener of Ultra-Low-Level Radioactive Surface Contamination

    Energy Technology Data Exchange (ETDEWEB)

    Golwala, Sunil R. [California Institute of Technology

    2013-12-20

    The eventual full-size, radiopure BetaCage will be a low-background, atmospheric-pressure neon drift chamber with unprecedented sensitivity to emitters of low-energy electrons and alpha particles. We expect that the prototype BetaCage already developed will be an excellent screener of alpha particles. Both the prototype and final BetaCage will provide new infrastructure for rare-event science.

  18. Two-proton energy spectra of 12O nucleus

    International Nuclear Information System (INIS)

    Teruya, N.

    2010-01-01

    Full text: The two-proton radioactivity has attracted stimulating discussion concerning the competing mechanisms for the decay process. Some nuclei (like 45 Fe, 41 Ni and 54 Zn are considered as genuine ground-state two-proton emitter because the only possibility is the simultaneous channel, but others nuclei (as 12 O) can also have the sequential decay, in this case, the energy levels of the intermediary one-proton emitter nuclei plays an important role to the competition with the simultaneous decay mode. In this work we have calculated the energy spectra of 12 O, including ground state and excited states up to 5 MeV of energy, and the two-proton energy difference spectrum for the ground state decay. Our preliminary results estimates the energy peak and width of resonant excited states and contributions of simultaneous and sequential channels for ground state decay. The calculation method is based on the statistical analysis for two-proton decaying modes presented in previous work. For events generated by sequential channels, the energy levels of intermediary 11 N nucleus can dominate the first proton emission, depending on the proximity between the ground states of both nuclei, 11 N and 12 O , in particular, if the ground state of 11 N is broad and its energy is far away from that of 12 O, the sequential decay occurs via the tail of the ground state of 11 O. The decay of 12 O resonant ground state and higher energy excited resonances are investigated through the analysis of the experimental data for the two-proton emission process. The two proton decay spectra have been considered in a statistical calculation framework, by using the decay energy distribution and taken into account the intermediate states of 11 N resonant structures for the sequential channels. For simultaneous decay channel we construct a symmetric distribution similarly to Goldansky's proposition in Nucl. Phys. A19, 482 (1960). (author)

  19. Charged-particle activation analysis

    International Nuclear Information System (INIS)

    Schweikert, E.A.

    1978-01-01

    The paper discusses the methodology and application of nuclear activation with ion beams (1 9 via 16 O( 3 He,p) 18 F, 12 C( 3 He,α) 11 C and 14 N(p,α) 11 C respectively. Recently, triton activation has been shown to be inherently still superior to 3 He activation for the determination of oxygen [ 16 O( 3 H,n) 18 F]. Lithium, boron, carbon and sulphur can be detected rapidly, nondestructively and with high sensitivity (approximately 0.25ppm for Li and B) via ''quasi-prompt'' activation based on the detection of short-lived, high-energy beta emitters (10ms 1 H( 7 Li,n) 7 Be for example. Nondestructive multielement analysis: Proton activation has the inherent potential for meeting requirements of broad elemental coverage, sensitivity (ppm and sub-ppm range) and selectivity. Up to 30 elements have been determined in Al, Co, Ag, Nb, Rh, Ta and biological samples, using 12-MeV proton activation followed by gamma-ray spectrometry. These capabilities are further enhanced with the counting of X-ray emitters, 28 elements (26 9 ) and accuracy using proton activation. 204 Pb/ 206 Pb ratios can also be determined with a relative precision of a few per cent. Although charged-particle activation analysis is a well-established trace analysis technique, broad potential capabilities remain to be explored, e.g. those arising from ultrashort-lived nuclides, heavy ion interactions and the combination of delayed and prompt methods. (author)

  20. Proton therapy treatment monitoring with the DoPET system: activity range, positron emitters evaluation and comparison with Monte Carlo predictions

    Science.gov (United States)

    Muraro, S.; Battistoni, G.; Belcari, N.; Bisogni, M. G.; Camarlinghi, N.; Cristoforetti, L.; Del Guerra, A.; Ferrari, A.; Fracchiolla, F.; Morrocchi, M.; Righetto, R.; Sala, P.; Schwarz, M.; Sportelli, G.; Topi, A.; Rosso, V.

    2017-12-01

    Ion beam irradiations can deliver conformal dose distributions minimizing damage to healthy tissues thanks to their characteristic dose profiles. Nevertheless, the location of the Bragg peak can be affected by different sources of range uncertainties: a critical issue is the treatment verification. During the treatment delivery, nuclear interactions between the ions and the irradiated tissues generate β+ emitters: the detection of this activity signal can be used to perform the treatment monitoring if an expected activity distribution is available for comparison. Monte Carlo (MC) codes are widely used in the particle therapy community to evaluate the radiation transport and interaction with matter. In this work, FLUKA MC code was used to simulate the experimental conditions of irradiations performed at the Proton Therapy Center in Trento (IT). Several mono-energetic pencil beams were delivered on phantoms mimicking human tissues. The activity signals were acquired with a PET system (DoPET) based on two planar heads, and designed to be installed along the beam line to acquire data also during the irradiation. Different acquisitions are analyzed and compared with the MC predictions, with a special focus on validating the PET detectors response for activity range verification.

  1. Shielding in ungated field emitter arrays

    Energy Technology Data Exchange (ETDEWEB)

    Harris, J. R. [U.S. Navy Reserve, Navy Operational Support Center New Orleans, New Orleans, Louisiana 70143 (United States); Jensen, K. L. [Code 6854, Naval Research Laboratory, Washington, D.C. 20375 (United States); Shiffler, D. A. [Directed Energy Directorate, Air Force Research Laboratory, Albuquerque, New Mexico 87117 (United States); Petillo, J. J. [Leidos, Billerica, Massachusetts 01821 (United States)

    2015-05-18

    Cathodes consisting of arrays of high aspect ratio field emitters are of great interest as sources of electron beams for vacuum electronic devices. The desire for high currents and current densities drives the cathode designer towards a denser array, but for ungated emitters, denser arrays also lead to increased shielding, in which the field enhancement factor β of each emitter is reduced due to the presence of the other emitters in the array. To facilitate the study of these arrays, we have developed a method for modeling high aspect ratio emitters using tapered dipole line charges. This method can be used to investigate proximity effects from similar emitters an arbitrary distance away and is much less computationally demanding than competing simulation approaches. Here, we introduce this method and use it to study shielding as a function of array geometry. Emitters with aspect ratios of 10{sup 2}–10{sup 4} are modeled, and the shielding-induced reduction in β is considered as a function of tip-to-tip spacing for emitter pairs and for large arrays with triangular and square unit cells. Shielding is found to be negligible when the emitter spacing is greater than the emitter height for the two-emitter array, or about 2.5 times the emitter height in the large arrays, in agreement with previously published results. Because the onset of shielding occurs at virtually the same emitter spacing in the square and triangular arrays, the triangular array is preferred for its higher emitter density at a given emitter spacing. The primary contribution to shielding in large arrays is found to come from emitters within a distance of three times the unit cell spacing for both square and triangular arrays.

  2. Search for Long-Lived Neutral Particles in Final states with Delayed Photon and Missing Transverse Energy from Proton-Proton Collisions using the CMS detector

    CERN Document Server

    AUTHOR|(CDS)2080019; Kubota, Yuichi; Kao, Shih-Chuan; Kubota, Yuichi

    2016-12-01

    We perform a search for long-lived neutral particles in final state with delayed photons and large missing transverse energy produced in LHC proton-proton collisions at center-of-mass energy, $\\sqrt{s} = 8\\TeV$. Capitalizing on the excellent timing resolution of the CMS Electromagnetic Calorimeter the search uses photon time measurements made by the Electromagnetic Calorimeter as the main search quantity. We found a single event consistent with our background expectations from the Standard Model and set a model-independent upper limit of 4.37 on number of signal events. We also interpret our results in the context of the SPS8 benchmark GMSB model and show that neutralinos with mean lifetime, $\\tau \\leq 45$ns, and mass, $m \\leq 300\\GeV/c^{2}$, or effective Supersymmetry breaking energy scale, $\\Lambda \\leq 220\\TeV$, are ruled out of existence at 95% $CL_{S}$ confidence level. The exclusion limit on the product of the production cross-section and branching ratio of the neutralino to photon and gravitino decay ...

  3. Precipitation in Zr-2.5Nb enhanced by proton irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Cann, C. D.; So, C. B.; Styles, R. C.; Coleman, C. E.

    1993-08-15

    A 3.6 MeV proton irradiation of annealed Zr-2.5Nb has been performed to determine whether proton irradiation will enhance the precipitation of Nb-rich {beta}-phase precipitates within the {alpha}-grains. a transmission electron microscope examination of a foil after irradiation at 770 K for 18 h and at 720 K for 264.5 h to a total damage of 0.94 dpa revealed a fine dispersion of precipitates within the {alpha}-grains. Electron diffraction analysis of the precipitates found they have lattice plane spacings consistent with the Nb-rich {beta}-phase. This result is in agreement with the {beta}phase precipitation observed following neutron irradiation, and thus it supports the use of proton irradiation to simulate neutron-irradiation effects in Zr-2.5Nb.

  4. Coherent single-photon absorption by single emitters coupled to one-dimensional nanophotonic waveguides

    Energy Technology Data Exchange (ETDEWEB)

    Chen Yuntian; Wubs, Martijn; Moerk, Jesper [DTU Fotonik, Department of Photonics Engineering, Oersteds Plads, DK-2800 Kgs Lyngby (Denmark); Koenderink, A Femius, E-mail: yche@fotonik.dtu.dk [Center for Nanophotonics, FOM Institute for Atomic and Molecular Physics (AMOLF), Science Park 104, 1098 XG Amsterdam (Netherlands)

    2011-10-15

    We study the dynamics of single-photon absorption by a single emitter coupled to a one-dimensional waveguide that simultaneously provides channels for spontaneous emission (SE) decay and a channel for the input photon. We have developed a time-dependent theory that allows us to specify any input single-photon wavepacket guided by the waveguide as the initial condition, and calculate the excitation probability of the emitter, as well as the time evolution of the transmitted and reflected fields. For single-photon wavepackets with a Gaussian spectrum and temporal shape, we obtain analytical solutions for the dynamics of absorption, with maximum atomic excitation {approx}40%. We furthermore propose a terminated waveguide to aid the single-photon absorption. We found that for an emitter placed at an optimal distance from the termination, the maximum atomic excitation due to an incident single-photon wavepacket can exceed 70%. This high value is a direct consequence of the high SE {beta}-factor for emission into the waveguide. Finally, we have also explored whether waveguide dispersion could aid single-photon absorption by pulse shaping. For a Gaussian input wavepacket, we found that the absorption efficiency can be improved by a further 4% by engineering the dispersion. Efficient single-photon absorption by a single emitter has potential applications in quantum communication and quantum computation. (paper)

  5. Development of a Laser-based Emittance Monitor for Negative Hydrogen Beams

    CERN Document Server

    AUTHOR|(CDS)2078368; Schmauss, Bernhard; Gibson, Stephen; Boorman, Gary; Bosco, Alessio

    High energy particle accelerators are designed to collide charged particle beams and thus study the collision products. Maximising the collision rate, to generate sufficient statistics for precise measurements of rare processes, is one of the key parameters for optimising the overall collider performance. The CERN Large Hadron Collider (LHC) Injectors Upgrade (LIU) includes the construction of LINAC4, a completely new machine working as a first linear acceleration stage for the LHC beam. By accelerating a negative hydrogen beam (H-) instead of protons, it aims to double the beam brightness via a more efficient transfer to the first circular accelerator and subsequently boost the LHC collision rate. To achieve this, a precise knowledge of the transverse beam characteristics in terms of beam emittance is essential. This thesis work covers the development of a laser-based monitor meant to measure non-destructively the LINAC4 beam transverse profile and emittance. This included the implementation of dif...

  6. The decay modes of proton drip-line nuclei with A between 42 and 47

    International Nuclear Information System (INIS)

    Borrel, V.; Dogny, S.; Guillemaud-Mueller, D.; Mueller, A.C.; Pougheon, F.; Sorlin, O.; Bazin, D.; Del Moral, R.; Dufour, J.P.; Faux, L.; Fleury, A.; Hubert, F.; Marchand, C.; Pravikoff, M.S.; Chubarian, G.G.

    1992-01-01

    Neutron-deficient isotopes with Z = 21 to 26 have been produced as projectile-like fragments of an intense 58 Ni GANIL beam of 69 MeV/nucleon. The nuclei selected by the upgraded LISE3 spectrometer were identified and implanted in a silicon detector telescope. The 43 Cr, 47 Fe and 46 Fe isotopes were identified for the first time whereas 45 Fe, 45 Mn, 44 Mn and 42 V were not observed, indicating probable instability of these nuclei against particle emission. Measurements of the half-lives of 43 Cr and 46 Mn have been performed and the analysis of their measured beta-delayed proton spectra has given, through the Isobaric Multiplet Mass Equation, an empirical estimation of their masses. Half-lives of 44 Cr, 43 V, 47 Fe and 46 Fe have also been measured. A discussion of various mass predictions for nuclei at the proton drip-line is given

  7. Nuclear properties for astrophysical applications

    Energy Technology Data Exchange (ETDEWEB)

    Moeller, P.; Nix, J.R. [Los Alamos National Lab., NM (United States); Kratz, K.L. [Mainz Univ. (Germany). Inst. fuer Kernchemie

    1994-09-23

    We tabulate the ground-state odd-proton and odd-neutron spins, proton and neutron pairing gaps, binding energies, neuton separation energies, quantities related to {beta}-delayed one, two and three neutron emission probabilities, {beta}-decay Q values and half-lives with respect to Gamow-Teller decay, proton separation energies, and {alpha}-decay Q values and half-lives. The starting point of the calculations is a calculation of nuclear ground-states and (information based on the finite-range droplet model and the folded-Yukawa single-particle model published in a previous issue of ATOMIC DATA AND NUCLEAR DATA TABLES. The {beta}-delayed neutron-emission probabilities and Gamow-Teller {beta}-decay rates are obtained from a QRPA model that uses single-particle levels and wave-functions at the calculated nuclear ground-state shape as the starting point.

  8. Recent technologic developments on high-resolution beta imaging systems for quantitative autoradiography and double labeling applications

    CERN Document Server

    Barthe, N; Chatti, K; Coulon, P; Maitrejean, S; 10.1016/j.nima.2004.03.014

    2004-01-01

    Two novel beta imaging systems, particularly interesting in the field of radiopharmacology and molecular biology research, were developed these last years. (1) a beta imager was derived from research conducted by Pr Charpak at CERN. This parallel plate avalanche chamber is a direct detection system of beta radioactivity, which is particularly adapted for qualitative and quantitative autoradiography. With this detector, autoradiographic techniques can be performed with emitters such as /sup 99m/Tc because this radionuclide emits many low-energy electrons and the detector has a very low sensitivity to low-range gamma -rays. Its sensitivity (smallest activity detected: 0.007 cpm/mm/sup 2/ for /sup 3/H and 0.01 for /sup 14/C), linearity (over a dynamic range of 10/sup 4/) and spatial resolution (50 mu m for /sup 3/H or /sup 99m/Tc to 150 mu m for /sup 32/P or /sup 18/F ( beta /sup +/)) gives a real interest to this system as a new imaging device. Its principle of detection is based on the analysis of light emitte...

  9. Estimation of radiation exposures due to the exemption of beta-contaminated radioactive materials

    International Nuclear Information System (INIS)

    Beltz, D.; Botsch, W.; Huettig, M.; Boerchers, F.

    2005-01-01

    The authors have checked the individual clearance levels of pure beta-emitters (Sr 89, Sr 90+) according to Anlage III, Table 1, column 8 and 10 StrlSchV for the clearance of buildings. According to Monte-Carlo simulations the direct exposure coming from contaminated parts of a building can exceed the range of trivial doses significantly, although the clearance levels are met. Furthermore, the high radiation level outside a barrel of beta-emitting waste showed that even the mass-specific clearance levels for the disposal of beta-contaminated waste need to be reviewed. (orig.)

  10. Prospects for studies of ground-state proton decays with the Holifield Radioactive Ion Beam Facility

    International Nuclear Information System (INIS)

    Toth, K.S.

    1994-01-01

    By using radioactive ions from the Holifield Radioactive Ion Beam Facility at Oak Ridge National Laboratory it should be possible to identify many new ground-state proton emitters in the mass region from Sn to Pb. During this production and search process the limits of stability on the proton-rich side of the nuclidic chart will be delineated for a significant fraction of medium-weight elements and our understanding of the proton-emission process will be expanded and improved

  11. Monolithic multinozzle emitters for nanoelectrospray mass spectrometry

    Science.gov (United States)

    Wang, Daojing [Daly City, CA; Yang, Peidong [Kensington, CA; Kim, Woong [Seoul, KR; Fan, Rong [Pasadena, CA

    2011-09-20

    Novel and significantly simplified procedures for fabrication of fully integrated nanoelectrospray emitters have been described. For nanofabricated monolithic multinozzle emitters (NM.sup.2 emitters), a bottom up approach using silicon nanowires on a silicon sliver is used. For microfabricated monolithic multinozzle emitters (M.sup.3 emitters), a top down approach using MEMS techniques on silicon wafers is used. The emitters have performance comparable to that of commercially-available silica capillary emitters for nanoelectrospray mass spectrometry.

  12. Diffractive Deep-Inelastic Scattering with a Leading Proton at HERA

    CERN Document Server

    Aktas, A.; Anthonis, T.; Antunovic, B.; Aplin, S.; Asmone, A.; Astvatsatourov, A.; Babaev, A.; Backovic, S.; Baghdasaryan, A.; Baranov, P.; Barrelet, E.; Bartel, W.; Baudrand, S.; Baumgartner, S.; Beckingham, M.; Behnke, O.; Behrendt, O.; Belousov, A.; Berger, N.; Bizot, J.C.; Boenig, M.-O.; Boudry, V.; Bracinik, J.; Brandt, G.; Brisson, V.; Bruncko, D.; Busser, F.W.; Bunyatyan, A.; Buschhorn, G.; Bystritskaya, L.; Campbell, A.J.; Cassol-Brunner, F.; Cerny, K.; Cerny, V.; Chekelian, V.; Contreras, J.G.; Coughlan, J.A.; Cox, B.E.; Cozzika, G.; Cvach, J.; Dainton, J.B.; Dau, W.D.; Daum, K.; de Boer, Y.; Delcourt, B.; Del Degan, M.; De Roeck, A.; De Wolf, E.A.; Diaconu, C.; Dodonov, V.; Dubak, A.; Eckerlin, Guenter; Efremenko, V.; Egli, S.; Eichler, R.; Eisele, F.; Eliseev, A.; Elsen, E.; Essenov, S.; Falkewicz, A.; Faulkner, P.J.W.; Favart, L.; Fedotov, A.; Felst, R.; Feltesse, J.; Ferencei, J.; Finke, L.; Fleischer, M.; Flucke, G.; Fomenko, A.; Franke, G.; Frisson, T.; Gabathuler, E.; Garutti, E.; Gayler, J.; Gerlich, C.; Ghazaryan, Samvel; Ginzburgskaya, S.; Glazov, A.; Glushkov, I.; Goerlich, L.; Goettlich, M.; Gogitidze, N.; Gorbounov, S.; Grab, C.; Greenshaw, T.; Gregori, M.; Grell, B.R.; Grindhammer, G.; Gwilliam, C.; Haidt, D.; Hansson, M.; Heinzelmann, G.; Henderson, R.C.W.; Henschel, H.; Herrera, G.; Hildebrandt, M.; Hiller, K.H.; Hoffmann, D.; Horisberger, R.; Hovhannisyan, A.; Hreus, T.; Hussain, S.; Ibbotson, M.; Ismail, M.; Jacquet, M.; Janssen, X.; Jemanov, V.; Jonsson, L.; Johnson, D.P.; Jung, Andreas Werner; Jung, H.; Kapichine, M.; Katzy, J.; Kenyon, I.R.; Kiesling, Christian M.; Klein, M.; Kleinwort, C.; Klimkovich, T.; Kluge, T.; Knies, G.; Knutsson, A.; Korbel, V.; Kostka, P.; Krastev, K.; Kretzschmar, J.; Kropivnitskaya, A.; Kruger, K.; Landon, M.P.J.; Lange, W.; Lastovicka-Medin, G.; Laycock, P.; Lebedev, A.; Leibenguth, G.; Lendermann, V.; Levonian, S.; Lindfeld, L.; Lipka, K.; Liptaj, A.; List, B.; List, J.; Lobodzinska, E.; Loktionova, N.; Lopez-Fernandez, R.; Lubimov, V.; Lucaci-Timoce, A.-I.; Lueders, H.; Lux, T.; Lytkin, L.; Makankine, A.; Malden, N.; Malinovski, E.; Marage, P.; Marshall, R.; Marti, L.; Martisikova, M.; Martyn, H.-U.; Maxfield, S.J.; Mehta, A.; Meier, K.; Meyer, A.B.; Meyer, H.; Meyer, J.; Michels, V.; Mikocki, S.; Milcewicz-Mika, I.; Milstead, D.; Mladenov, D.; Mohamed, A.; Moreau, F.; Morozov, A.; Morris, J.V.; Mozer, Matthias Ulrich; Muller, K.; Murin, P.; Nankov, K.; Naroska, B.; Naumann, Th.; Newman, Paul R.; Niebuhr, C.; Nikiforov, A.; Nowak, G.; Nowak, K.; Nozicka, M.; Oganezov, R.; Olivier, B.; Olsson, J.E.; Osman, S.; Ozerov, D.; Palichik, V.; Panagoulias, I.; Papadopoulou, T.; Pascaud, C.; Patel, G.D.; Peng, H.; Perez, E.; Perez-Astudillo, D.; Perieanu, A.; Petrukhin, A.; Pitzl, D.; Placakyte, R.; Portheault, B.; Povh, B.; Prideaux, P.; Rahmat, A.J.; Raicevic, N.; Reimer, P.; Rimmer, A.; Risler, C.; Rizvi, E.; Robmann, P.; Roland, B.; Roosen, R.; Rostovtsev, A.; Rurikova, Z.; Rusakov, S.; Salvaire, F.; Sankey, D.P.C.; Sauter, M.; Sauvan, E.; Schilling, F.-P.; Schmidt, S.; Schmitt, S.; Schmitz, C.; Schoeffel, L.; Schoning, A.; Schultz-Coulon, H.-C.; Sefkow, F.; Shaw-West, R.N.; Sheviakov, I.; Shtarkov, L.N.; Sloan, T.; Smirnov, P.; Soloviev, Y.; South, D.; Spaskov, V.; Specka, Arnd E.; Steder, M.; Stella, B.; Stiewe, J.; Stoilov, A.; Straumann, U.; Sunar, D.; Tchoulakov, V.; Thompson, G.; Thompson, P.D.; Toll, T.; Tomasz, F.; Traynor, D.; Trinh, T.N.; Truol, P.; Tsakov, I.; Tsipolitis, G.; Tsurin, I.; Turnau, J.; Tzamariudaki, E.; Urban, K.; Urban, Marcel; Usik, A.; Utkin, D.; Valkarova, A.; Vallee, C.; Van Mechelen, P.; Vargas Trevino, A.; Vazdik, Y.; Veelken, C.; Vinokurova, S.; Volchinski, V.; Wacker, K.; Weber, G.; Weber, R.; Wegener, D.; Werner, C.; Wessels, M.; Wessling, B.; Wissing, Ch.; Wolf, R.; Wunsch, E.; Xella, S.; Yan, W.; Yeganov, V.; Zacek, J.; Zalesak, J.; Zhang, Z.; Zhelezov, A.; Zhokin, A.; Zhu, Y.C.; Zimmermann, J.; Zimmermann, T.; Zohrabyan, H.; Zomer, F.

    2006-01-01

    The cross section for the diffractive deep-inelastic scattering process $ep \\to e X p$ is measured, with the leading final state proton detected in the H1 Forward Proton Spectrometer. The data analysed cover the range \\xpom <0.1 in fractional proton longitudinal momentum loss, 0.08 < |t| < 0.5 GeV^{-2} in squared four-momentum transfer at the proton vertex, 2 < Q^2 < 50 GeV^2 in photon virtuality and 0.004 < \\beta = x / \\xpom < 1, where x is the Bjorken scaling variable. For $\\xpom \\lapprox 10^{-2}$, the differential cross section has a dependence of approximately ${\\rm d} \\sigma / {\\rm d} t \\propto e^{6 t}$, independently of \\xpom, \\beta and Q^2 within uncertainties. The cross section is also measured triple differentially in \\xpom, \\beta and Q^2. The \\xpom dependence is interpreted in terms of an effective pomeron trajectory with intercept $\\alpha_{\\pom}(0)=1.114 \\pm 0.018 ({\\rm stat.}) \\pm 0.012 ({\\rm syst.}) ^{+0.040}_{-0.020} ({\\rm model})$ and a sub-leading exchange. The data are in...

  13. Study of proton polarization in charge exchange process on optically oriented sodium atoms

    International Nuclear Information System (INIS)

    Zelenskij, A.N.; Kokhanovskij, S.A.

    1984-01-01

    Using high-power adjustable dye lasers for electron spin orientation in a charge-exchange target enables to significantly increase the proton polarization efficiency. A device is described that permits to avoid growth of the polarized proton beam emittance in a charge-exchange process in a strong magnetic field. The devise main feature is the use of an intensive source of neutral hydrogen atoms and the presence of a helium additional charge-exchange target which actualy is a proton ''source''. The helium charge-exchange cell is placed in the same magnetic field of a solenoid where a cell with oriented sodium is placed, a polarized electron being captured by a proton in the latter cell. In this case the beam at the solenoid inlet and outlet is in a neutral state; emittance growth related to the effect of end magnetic fields is not observed. The device after all prouduces polarized protons, their polarization degree is measured and the effect of various factors on polarization degree is studied. The description of the laser source and laser system is given. Measurement results have shown the beam intensity of neutral 7 keV atoms which passed through a polarizer to be 2 mA. The proton current doesn't depend. On the beeld fin the region of chrge exchange for the 8 kGs magnetic field. The degree of sodium polarization was 80% and polarized proton current approximately 70 μA at a temperature of the polarized sodium cell corresponding to the density of sodium vapar approximately 3x10 13 at/cm 2

  14. Beta-decay of {sup 56}Cu

    Energy Technology Data Exchange (ETDEWEB)

    Ramdhane, M.; Baumann, P.; Knipper, A.; Walter, G. [Institute de Recherches Subatomiques, 67 - Strasbourg (France); Janas, Z.; Plochocki, A. [Warsaw Univ. (Poland). Inst. of Experimental Physics; Aeystoe, J.; Dendooven, P.; Jokinen, A.; Oinonen, M.; Pentilae, H. [Jyvaeskylae Univ. (Finland); Liu, W.; Grawe, H.; Hu, Z.; Kirchner, R.; Klepper, O.; Roeckl, E. [Gesellschaft fuer Schwerionenforschung mbH, Darmstadt (Germany); Gorska, M. [Warsaw Univ. (Poland). Inst. of Experimental Physics]|[Gesellschaft fuer Schwerionenforschung mbH, Darmstadt (Germany); Fujita, Y. [Osaka Univ. (Japan); Brown, B.A. [Michigan State Univ., East Lansing, MI (United States)

    1998-02-01

    By measuring positrons and {beta}-delayed {gamma}-rays emitted from mass-separated sources, the decay of {sup 56}Cu(4{sup +},T{sub z}=-1,T=1) to states in the doubly-magic nucleus {sup 56}Ni was studied for the first time. The half-life of {sup 56}Cu was measured to be 78(15) ms, and four {beta}-delayed {gamma}-rays were assigned to its decay. The resulting experimental data on Fermi and Gamow-Teller strength are compared with shell-model predictions. (orig.)

  15. Efficient, deep-blue TADF-emitters for OLED display applications (Conference Presentation)

    Science.gov (United States)

    Volz, Daniel; Baumann, Thomas

    2016-09-01

    Currently, the mobile display market is strongly shifting towards AMOLED technology, in order to enable curved and flexible displays. This leads to a growing demand for highly efficient OLED emitters to reduce the power consumption and increase display resolution at the same time. While highly efficient green and red OLEDs already found their place in commercial OLED-displays, the lack of efficient blue emitters is still an issue. Consequently, the active area for blue is considerably larger than for green and red pixels, to make up for the lower efficiency. We intend to close this efficiency-gap with novel emitters based on thermally activated delayed fluorescence (TADF) technology. Compared to state-of-the-art fluorescent dopants, the efficiency of TADF-emitters is up to four times higher. At the same time, it is possible to design them in a way to maintain deep blue emission, i.e. CIE y < 0.2. These aspects are relevant to produce efficient high resolution AMOLED displays. Apart from these direct customer benefits, our TADF technology does not contain any rare elements, which allows for the fabrication of sustainable OLED technology. In this work, we highlight one of our recently developed blue TADF materials. Basic material properties as well as first device results are discussed. In a bottom-emitting device, a CIEx/CIEy coordinate of (0.16/0.17) was achieved with efficiency values close to 20% EQE.

  16. Laser based stripping system for measurement of the transverse emittance of H-beams at the CERN Linac4

    CERN Document Server

    Hofmann, T; Raich, U; Roncarolo, F; Cheymol, B

    2013-01-01

    The new LINAC4 at CERN will accelerate H- particles to 160 MeV and allow high brightness proton beam transfers to the Proton Synchrotron Booster, via a charge-exchange injection scheme. This paper describes the conceptual design of a laser system proposed for transverse profile and emittance measurements based on photon detachment of electrons from the H- ions. The binding energy of the outer electron is only 0.75 eV and can easily be stripped with a laser beam. Measuring the electron signal as function of the laser position allows the transverse beam profile to be reconstructed. A downstream dipole can also be used to separate the laser neutralized H0 atoms from the main H- beam. By imaging these H0 atoms as a function of laser position the transverse emittance can be reconstructed in the same way as in traditional slit-and-grid systems. By properly dimensioning the laser power and spot size, this method results in negligible beam losses and is therefore non-destructive. In addition, the absence of material ...

  17. Spectroscopy at the two-proton drip line: Excited states in 158W

    Directory of Open Access Journals (Sweden)

    D.T. Joss

    2017-09-01

    Full Text Available Excited states have been identified in the heaviest known even-Z N=84 isotone 158W, which lies in a region of one-proton emitters and the two-proton drip line. The observation of γ-ray transitions feeding the ground state establishes the excitation energy of the yrast 6+ state confirming the spin-gap nature of the α-decaying 8+ isomer. The 8+ isomer is also expected to be unbound to two-proton emission but no evidence for this decay mode was observed. An upper limit for the two-proton decay branch has been deduced as b2p≤ 0.17% at the 90% confidence level. The possibility of observing two-proton emission from multiparticle isomers in nearby nuclides is considered.

  18. Spectroscopy at the two-proton drip line: Excited states in 158W

    Science.gov (United States)

    Joss, D. T.; Page, R. D.; Herzán, A.; Donosa, L.; Uusitalo, J.; Carroll, R. J.; Darby, I. G.; Andgren, K.; Cederwall, B.; Eeckhaudt, S.; Grahn, T.; Greenlees, P. T.; Hadinia, B.; Jakobsson, U.; Jones, P. M.; Julin, R.; Juutinen, S.; Leino, M.; Leppanen, A.-P.; Nyman, M.; O'Donnell, D.; Pakarinen, J.; Rahkila, P.; Sandzelius, M.; Sarén, J.; Scholey, C.; Seweryniak, D.; Simpson, J.; Sorri, J.

    2017-09-01

    Excited states have been identified in the heaviest known even-Z N = 84 isotone 158W, which lies in a region of one-proton emitters and the two-proton drip line. The observation of γ-ray transitions feeding the ground state establishes the excitation energy of the yrast 6+ state confirming the spin-gap nature of the α-decaying 8+ isomer. The 8+ isomer is also expected to be unbound to two-proton emission but no evidence for this decay mode was observed. An upper limit for the two-proton decay branch has been deduced as b2p ≤ 0.17% at the 90% confidence level. The possibility of observing two-proton emission from multiparticle isomers in nearby nuclides is considered.

  19. Beta-Delayed Neutron Spectroscopy of 72Co with VANDLE

    Science.gov (United States)

    Keeler, Andrew; Grzywacz, Robert; King, Thomas; Taylor, Steven; Paulauskas, Stanley; Zachary, Christopher; Vandle Collaboration

    2017-09-01

    Measurements of simple, closed-shell isotopes far from stability provide important benchmarks for nuclear models and are a key constraint in r-process calculations. In particular, r-process models are sensitive to beta decay lifetimes and branching ratios of these neutron-rich isotopes. In this experiment, the Versatile Array of Neutron Detectors at Low Energy (VANDLE) was used to observe decays of nuclei produced by the fragmentation of 82Se at the National Superconducting Cyclotron Laboratory (NSCL). The neutron and gamma emissions of 72Co were measured to map the beta strength distribution (S_beta) above the neutron separation energy and infer the size of the Z = 28 shell gap in the 78Ni region. An implantation detector made of a radiation-hardened, inorganic scintillator was used to correlate implanted ions with beta decays as well as provide a start signal for the neutron Time of Flight measurement. Funded by the National Nuclear Security Administration under the Stewardship Science Academic Alliances program through DOE Award No. DE-NA0002132 and by the Office of Nuclear Physics, U.S. Department of Energy under Awards No. DE-FG02-96ER40983 (UTK).

  20. Collective centroid oscillations as an emittance preservation diagnostic in linear collider linacs

    International Nuclear Information System (INIS)

    Adolphsen, C.E.; Bane, K.L.F.; Spence, W.L.; Woodley, M.D.

    1997-08-01

    Transverse bunch centroid oscillations, induced at operating beam currents at which transverse wakefields are substantial, and observed at Beam Position Monitors, are sensitive to the actual magnetic focusing, energy gain, and rf phase profiles in a linac, and are insensitive to misalignments and jitter sources. In the pulse stealing set-up implemented at the SLC, they thus allow the frequent monitoring of the stability of the in-place emittance growth inhibiting or mitigating measures--primarily the energy scaled magnetic lattice and the rf phases necessary for BNS damping--independent of the actual emittance growth as driven by misalignments and jitter. The authors have developed a physically based analysis technique to meaningfully reduce the data. Oscillation beta-beating is a primary indicator of beam energy errors; shifts in the invariant amplitude reflect differential internal motion along the longitudinally extended bunch and thus are a sensitive indicator of the real rf phases in the machine; shifts in betatron phase advance contain corroborative information sensitive to both effects

  1. Determination of 131mXe and 133mXe in the presence of 133gXe via combined beta-spectroscopy and delayed coincidence

    International Nuclear Information System (INIS)

    Reeder, P.L.; Bowyer, T.W.; McIntyre, J.I.; Pitts, W.K.

    2001-01-01

    The International Monitoring System for the Comprehensive Nuclear-Test-Ban Treaty will include measurements of Xe fission products. Pacific Northwest National Laboratory has developed an automated system for separating Xe from air which detects Xe fission products using a beta-gamma counting system for 131m Xe, 133m Xe, 133g Xe, and 135g Xe. Betas and conversion electrons are detected in a plastic scintillation cell containing the Xe sample. Gamma and X-rays are detected in a NaI(Tl) scintillation detector which surrounds the plastic scintillator sample cell. Two-dimensional pulse-height spectra of gamma-energy versus beta-energy are obtained. The plastic scintillator spectrum in coincidence with the 31-keV X-rays from 131m Xe. 133m Xe, and 133g Xe is a complex mixture of conversion electrons and betas. A new technique to simultaneously measure the delayed coincidence (T 1/2 = 6.27 ns) between beta-particles from 133g Xe and conversion electrons depopulating the 81-keV state in 133 Cs is being developed. This technique allows separation of the 133g Xe beta spectrum from the conversion electrons due to 131m Xe and 133m Xe and uniquely quantifies all three nuclides. (author)

  2. Assessment of beta-emitter radionuclides in biological samples using liquid scintillation counting. Application to the study of internal doses in molecular and cellular biology techniques

    International Nuclear Information System (INIS)

    Sierra, I.; Delgado, A.; Navarro, T.; Macias, M. T.

    2007-01-01

    The radioisotopic techniques used in Molecular and Cellular Biology involve external and internal irradiation risk. It is necessary to control the possible internal contamination associated to the development of these techniques. The internal contamination risk can be due to physical and chemical properties of the labelled compounds, aerosols generated during the performance technique. The aim of this work was to estimate the possible intake of specific beta emitters during the technique development and to propose the required criterions to perform Individual Monitoring. The most representative radioisotopic techniques were selected attending their potential risk of internal contamination. Techniques were analysed applying IAEA methodology according to the used activity in each technique. It was necessary to identify the worker groups that would require individual monitoring on the base of their specific risk. Different measurement procedures were applied to study the possible intake in group risk and more than 160 persons were measured by in vitro bioassay. (Author) 96 refs

  3. Proton therapy

    International Nuclear Information System (INIS)

    Jongen, Y.

    1995-01-01

    Ideal radiotherapy deposits a large amount of energy in the tumour volume, and none in the surrounding healthy tissues. Proton therapy comes closer to this goal because of a greater concentration of dose, well defined proton ranges and points of energy release which are precisely known - the Bragg peak1. In the past, the development of clinical proton therapy has been hampered by complexity, size, and cost. To be clinically effective, energies of several hundred MeV are required; these were previously unavailable for hospital installations, and pioneering institutions had to work with complex, inadequate equipment originally intended for nuclear physics research. Recently a number of specialist organizations and commercial companies have been working on dedicated systems for proton therapy. One, IBA of Belgium, has equipment for inhouse hospital operation which encompasses a complete therapy centre, delivered as a turnkey package and incorporating a compact, automated, higher energy cyclotron with isocentric gantries. Their system will be installed at Massachusetts General Hospital, Boston. The proton therapy system comprises: - a 235 MeV isochronous cyclotron to deliver beams of up to 1.5 microamps, but with a hardware limitation to restrict the maximum possible dose; - variable energy beam (235 to 70 MeV ) with energy spread and emittance verification; - a beam transport and switching system to connect the exit of the energy selection system to the entrances of a number of gantries and fixed beamlines. Along the beam transport system, the beam characteristics are monitored with non-interceptive multiwire ionization chambers for automatic tuning; - gantries fitted with nozzles and beamline elements for beam control; both beam scattering and beam wobbling techniques are available for shaping the beam;

  4. FACET Emittance Growth

    Energy Technology Data Exchange (ETDEWEB)

    Frederico, J; Hogan, M.J.; Nosochkov, Y.; Litos, M.D.; Raubenheimer, T.; /SLAC

    2011-04-05

    FACET, the Facility for Advanced Accelerator and Experimental Tests, is a new facility being constructed in sector 20 of the SLAC linac primarily to study beam driven plasma wakefield acceleration. The FACET beamline consists of a chicane and final focus system to compress the 23 GeV, 3.2 nC electron bunches to {approx}20 {micro}m long and {approx}10 {micro}m wide. Simulations of the FACET beamline indicate the short-duration and large, 1.5% rms energy spread beams may suffer a factor of four emittance growth from a combination of chromaticity, incoherent synchrotron radiation (ISR), and coherent synchrotron radiation (CSR). Emittance growth is directly correlated to head erosion in plasma wakefield acceleration and is a limiting factor in single stage performance. Studies of the geometric, CSR, and ISR components are presented. Numerical calculation of the rms emittance can be overwhelmed by long tails in the simulated phase space distributions; more useful definitions of emittance are given. A complete simulation of the beamline is presented as well, which agrees with design specifications.

  5. FACET Emittance Growth

    International Nuclear Information System (INIS)

    Frederico, Joel

    2011-01-01

    FACET, the Facility for Advanced Accelerator and Experimental Tests, is a new facility being constructed in sector 20 of the SLAC linac primarily to study beam driven plasma wakefield acceleration. The FACET beamline consists of a chicane and final focus system to compress the 23 GeV, 3.2 nC electron bunches to ∼20 (micro)m long and ∼10 (micro)m wide. Simulations of the FACET beamline indicate the short-duration and large, 1.5% rms energy spread beams may suffer a factor of four emittance growth from a combination of chromaticity, incoherent synchrotron radiation (ISR), and coherent synchrotron radiation (CSR). Emittance growth is directly correlated to head erosion in plasma wakefield acceleration and is a limiting factor in single stage performance. Studies of the geometric, CSR, and ISR components are presented. Numerical calculation of the rms emittance can be overwhelmed by long tails in the simulated phase space distributions; more useful definitions of emittance are given. A complete simulation of the beamline is presented as well, which agrees with design specifications.

  6. Excitation functions of proton-induced reactions on natural Nd and production of radionuclides relevant for double beta decay: Completing measurement in 5-35 MeV energy range

    Czech Academy of Sciences Publication Activity Database

    Lebeda, Ondřej; Lozza, V.; Petzoldt, J.; Štursa, Jan; Zdychová, Vlasta; Zuber, K.

    2014-01-01

    Roč. 929, SEP (2014), s. 129-142 ISSN 0375-9474 R&D Projects: GA MŠk(XE) LM2011019 Institutional support: RVO:61389005 Keywords : proton activation * double beta decay * cross-section * production rates * natural neodymium Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 2.202, year: 2014

  7. Status of the anti-proton production beam in the CERN PS

    International Nuclear Information System (INIS)

    Cappi, R.; Evans, B.J.; Garoby, R.

    1990-01-01

    A new scheme was put into operation in November 1988 to upgrade the proton beam delivered by the 26 GeV Proton Synchrotron (PS) for anti-proton production. It makes use of quasi-adiabatic manipulations of the RF parameters to squeeze a beam filling 1/2 of the PS circumference into a 1/4 turn and can in theory preserve the longitudinal emittance. A maximum intensity of 1.68 e 13 ppp in 5 bunches at 26 GeV has been reached in the course of 22 weeks of operation. The limitations of the performance are analysed together with possible improvements. (author) 6 refs., 9 figs

  8. Nuclear structure at the proton dripline

    International Nuclear Information System (INIS)

    Maglione, Enrico; Ferreira, Lidia S.; Costa Lopes, Miguel

    2007-01-01

    Recent studies with exotic nuclei far from the stability region, lead to the discovery of one and two proton radioactivity, from ground state of spherical, as well as deformed nuclei. Isomeric decay and fine structure were also measured, and in some cases, a prompt proton and alpha particle emission was observed. It was established that, the majority of prompt particle decays proceeds from superdeformed initial states, into spherical daughter states, revealing a change of deformation during the decay. Proton radioactivity has been the unique way to probe nuclear structure mechanisms in this region of stability. Since proton emitters lie beyond the proton drip-line, they also give the possibility of observing Nilsson resonances. In fact, the experimental data on proton radioactivity in regionswhere theoretical models predict a certain deformation for the nucleus is consistent with the idea that the proton was in a single particle resonance state, in the field of the daughter nucleus. An important aspect of such calculations is the inclusion of the nuclear structure properties of the core,like the rotational spectrum of the daughter nucleus, and the pairing residual interaction. We will address various questions concerning what we have learned from the data and how far our theoretical models have taken us in the region of neutron deficient nuclei at the borders of stability. (Author)

  9. Observation and spectroscopy of new proton-unbound isotopes {sup 30}Ar and {sup 29}Cl - an interplay of prompt two-proton and sequential decay

    Energy Technology Data Exchange (ETDEWEB)

    Mukha, Ivan [Helmholzzentrum GSI, Darmstadt (Germany)

    2016-07-01

    Previously unknown isotopes {sup 30}Ar and {sup 29}Cl have been identified by measurement of the trajectories of their in-flight decay products {sup 28}S+p+p and {sup 28}S+p, respectively. The analysis of angular correlations of the fragments provided information on decay energies and structure of the parent states. The lowest states in {sup 30}Ar, {sup 29}Cl point to a violation of isobaric symmetry in structure of these unbound nuclei. The two-proton decay has been identified in a transition region between simultaneous two-proton and sequential proton emissions from the {sup 30}Ar ground state, which is characterized by an interplay of three-body and two-body decay mechanisms. Such a phenomenon, never observed before, may be common in 2p-unbound nuclei, and could be of interest for other disciplines dealing with few-body systems. In addition, the dramatic change of odd-even mass staggering in 2p-unbound nuclei and the fine structure in the 2p decay of the {sup 30}Ar*(2.9 MeV) state were indicated. An Optical Time-Projection Chamber was used in the same experiment to observe beta decays of stopped {sup 31}Ar ions, which passed the secondary target intact. With this detector, β-delayed 3p emission from {sup 31}Ar was observed.

  10. Up-Conversion Intersystem Crossing Rates in Organic Emitters for Thermally Activated Delayed Fluorescence: Impact of the Nature of Singlet vs Triplet Excited States

    KAUST Repository

    Samanta, Pralok Kumar

    2017-02-28

    The rates for up-conversion intersystem crossing (UISC) from the T1 state to the S1 state are calculated for a series of organic emitters with an emphasis on thermally activated delayed fluorescence (TADF) materials. Both the spin-orbit coupling and the energy difference between the S1 and T1 states (ΔEST) are evaluated, at the density functional theory (DFT) and time-dependent DFT levels. The calculated UISC rates and ΔEST values are found to be in good agreement with available experimental data. Our results underline that small ΔEST values and sizable spin-orbit coupling matrix elements have to be simultaneously realized in order to facilitate UISC and ultimately TADF. Importantly, the spatial separation of the highest occupied and lowest unoccupied molecular orbitals of the emitter, a widely accepted strategy for the design of TADF molecules, does not necessarily lead to a sufficient reduction in ΔEST; in fact, either a significant charge-transfer (CT) contribution to the T1 state or a minimal energy difference between the local-excitation and charge-transfer triplet states is required to achieve a small ΔEST. Also, having S1 and T1 states of a different nature is found to strongly enhance spin-orbit coupling, which is consistent with the El-Sayed rule for ISC rates. Overall, our results indicate that having either similar energies for the local-excitation and charge-transfer triplet states or the right balance between a substantial CT contribution to T1 and somewhat different natures of the S1 and T1 states, paves the way toward UISC enhancement and thus TADF efficiency improvement.

  11. QEC Values of the Superallowed β Emitters 50Mn and 54Co

    International Nuclear Information System (INIS)

    Eronen, T.; Elomaa, V.-V.; Hager, U.; Hakala, J.; Jokinen, A.; Kankainen, A.; Moore, I. D.; Penttilae, H.; Rahaman, S.; Rissanen, J.; Saastamoinen, A.; Sonoda, T.; Weber, C.; Aeystoe, J.; Hardy, J. C.; Rinta-Antila, S.

    2008-01-01

    Using a new fast cleaning procedure to prepare isomerically pure ion samples, we have measured the beta-decay Q EC values of the superallowed β emitters 50 Mn and 54 Co to be 7634.48(7) and 8244.54(10) keV, respectively, results which differ significantly from the previously accepted values. The corrected Ft values derived from our results strongly support new isospin-symmetry-breaking corrections that lead to a higher value of the up-down quark mixing element V ud and improved confirmation of the unitarity of the Cabibbo-Kobayashi-Maskawa matrix

  12. Alpha-beta-gamma spectrometer as an aid in directing decontamination of soils

    International Nuclear Information System (INIS)

    Berger, C.D.

    1981-01-01

    This technique permits rapid assessment of alpha-beta-gamma-emitter contamination in soils at sufficiently low concentrations to direct field operations. Of particular importance is its applicability during initial decommissioning and decontamination surveys when characterization of alpha and beta contamination in the presence of a high gamma background is necessary. This system has not yet been made portable for in-situ use, but it is expected that results willbe favorable when operated as a field instrument, resulting in simplified standard decontamination operation

  13. Trends in the study of light proton rich nuclei

    International Nuclear Information System (INIS)

    Moltz, D.M.; Aysto, J.; Hotchkis, M.A.C.; Cerny, J.

    1985-09-01

    Recent work in light proton-rich nuclei is reviewed. Evidence for the first T/sub z/ = -5/2 nuclide, 35 Ca, is presented. The mechanisms of two-proton emission following beta-decay is investigated. Future directions in this field are discussed. 23 refs., 5 figs

  14. Low emittance photoinjectors

    International Nuclear Information System (INIS)

    Ferrario, Massimo

    2001-01-01

    Photon colliders require high charge polarized electron beams with very low normalized emittances, possibly lower than the actual damping rings design goals. Recent analytical and numerical efforts in understanding beam dynamics in RF photoinjectors have raised again the question as to whether the performances of an RF electron gun based injector could be competitive with respect to a damping ring. As a matter of discussion we report in this paper the most recent results concerning low emittance photoinjector designs: the production of polarized electron beams by DC and/or RF guns is illustrated together with space charge compensation techniques and thermal emittance effects. New ideas concerning multi-gun injection system and generation of flat beams by RF gun are also discussed

  15. RHIC polarized proton-proton operation at 100 GeV in Run 15

    International Nuclear Information System (INIS)

    Schoefer, V.; Aschenauer, E. C.; Atoian, G.; Blaskiewicz, M.; Brown, K. A.; Bruno, D.; Connolly, R.; D Ottavio, T.; Drees, K. A.; Dutheil, Y.; Fischer, W.; Gardner, C.; Gu, X.; Hayes, T.; Huang, H.; Laster, J.; Liu, C.; Luo, Y.; Makdisi, Y.; Marr, G.; Marusic, A.; Meot, F.; Mernick, K.; Michnoff, R.; Marusic, A.; Minty, M.; Montag, C.; Morris, J.; Narayan, G.; Nemesure, S.; Pile, P.; Poblaguev, A.; Ranjbar, V.; Robert-Demolaize, G.; Roser, T.; Schmidke, W. B.; Severino, F.; Shrey, T.; Smith, K.; Steski, D.; Tepikian, S.; Trbojevic, D.; Tsoupas, N.; Tuozzolo, J.; Wang, G.; White, S.; Yip, K.; Zaltsman, A.; Zelenski, A.; Zeno, K.; Zhang, S. Y.

    2015-01-01

    The first part of RHIC Run 15 consisted of ten weeks of polarized proton on proton collisions at a beam energy of 100 GeV at two interaction points. In this paper we discuss several of the upgrades to the collider complex that allowed for improved performance. The largest effort consisted in commissioning of the electron lenses, one in each ring, which are designed to compensate one of the two beam-beam interactions experienced by the proton bunches. The e-lenses raise the per bunch intensity at which luminosity becomes beam-beam limited. A new lattice was designed to create the phase advances necessary for a beam-beam compensation with the e-lens, which also has an improved off-momentum dynamic aperture relative to previous runs. In order to take advantage of the new, higher intensity limit without suffering intensity driven emittance deterioration, other features were commissioned including a continuous transverse bunch-by-bunch damper in RHIC and a double harmonic RF cature scheme in the Booster. Other high intensity protections include improvements to the abort system and the installation of masks to intercept beam lost due to abort kicker pre-fires.

  16. Identification and systematical studies of the electron-capture delayed fission (ECDF) in the lead region

    CERN Multimedia

    Pauwels, D B; Lane, J

    2008-01-01

    In our recent experiment (March 2007) at the velocity filter SHIP(GSI) we observed the electron-capture delayed fission of the odd-odd isotope $^{194}$At. This is the first unambiguous identification of this phenomenon in the very neutron-deficient nuclei in the vicinity of the proton shell closure at Z=82. In addition, the total kinetic energy (TKE) for the daughter nuclide $^{194}$Po was measured, despite the fact that this isotope does not decay via spontaneous fission. Semi-empirical analysis of the electron-capture Q$_{EC}$ values and fission barriers B$_{f}$ shows that a relatively broad island of ECDF must exist in this region of the Nuclide Chart, with some of the nuclei having unusually high ECDF probabilities. Therefore, this Proposal is intended to initiate the systematic identification and study of $\\beta$-delayed fission at ISOLDE in the very neutron-deficient lead region. Our aim is to provide unique low-energy fission data (e.g. probabilities, TKE release, fission barriers and their isospin dep...

  17. Nonstochastic effects of different energy beta emitters on pig skin

    International Nuclear Information System (INIS)

    Peel, D.M.; Hopewell, J.W.; Wells, J.; Charles, M.W.

    1984-01-01

    Circular areas of pig skin from 1- to 40-mm diameter were irradiated with β emitters of high, medium, and low energies, 90 Sr, 170 Tm, and 147 Pm, respectively. The study provides information for radiological protection problems of localized skin exposures. During the first 16 weeks after irradiation 90 Sr produced a first reaction due to epithelial cell death followed by a second reaction attributable to damage to the dermal blood vessels. 170 Tm and 147 Pm produced the epithelial reaction only. The epithelial dose response varied as a function of β energy. The doses required to produce moist desquamation in 50% of 15- to 22.5-mm fields (ED 50 ) were 30-45 Gy from 90 Sr, approx.80 Gy from 170 Tm, and approx.500 Gy from 147 Pm. An area effect was observed in the epithelial response to 90 Sr irradiation. The ED 50 for moist desquamation ranged from approx.25 Gy for a 40-mm source to approx.450 Gy for a 1-mm source. It is also suggested that the area effects could be explained by different modes of epithelial repopulation after irradiation

  18. Advanced Time-Delayed Coincidence Studies of $^{31,32}$Mg from the $\\beta$-decays of $^{31,32}$Na

    CERN Multimedia

    Marechal, F; Plociennik, W A

    2002-01-01

    It is proposed to study the lifetime of the 2$_{1}^{+}$ 885.4 keV state in $^{32}$Mg by means of Advanced Time-Delayed $\\beta \\gamma \\gamma$(t) method with the precision in the half-life value of about $\\pm$ 1.5 ps. This would be an independent verification of the B(E2; 0$_{1}^{+} \\rightarrow$ 2$_{1}^{+}$) values obtained so far in a few studies using Coulomb excitations at intermediate beam energies. The advantage of time-delayed coincidence measurements is that they are free of corrections used in the Coulex studies, which strongly affect the deduced B(E2) results. In addition, we propose to study the lifetimes or lifetime limits of other states in nuclei populated in the decays of $^{31}$Na and $^{32}$Na, specifically focusing on the intruder negative parity band in $^{31}$Mg. As a side benefit to this investigation we expect high-quality $\\gamma \\gamma$ coincidences to reveal new excited states in both $^{31}$Mg and $^{32}$Mg. Our results from a brief test-measurement yield a lifetime of T$_{1/2}$ = 10.5(...

  19. Isochoric heating of DT fuels through PW-laser-produced proton beams

    International Nuclear Information System (INIS)

    Maynard, G.; Barriga-Carrasco, M.D.

    2005-01-01

    Laser Proton Source (LPS) can generate short bunch of energetic protons with a nearly zero initial emittance. It is thus expected that LPS can deposit a very high density of energy inside dense matter, in particular, in the context of fast ignition of an inertial fusion target. We investigate here one of the factors that can limit the density of deposited energy. It concerns the transverse diffusion, occurring during the transport between the LPS and DT. As the rear surface of LPS should be efficiently protected, the proton along its path has to interact with a substantial amount of high-Z material. Therefore the induced transverse dispersion can become significant. The transport of the proton beam inside a plasma target is calculated using a numerical code, which main features are presented

  20. Isochoric heating of DT fuels through PW-laser-produced proton beams

    Energy Technology Data Exchange (ETDEWEB)

    Maynard, G. [Laboratoire de Physique des Gaz et des Pasmas, CNRS UMR8578, bat. 210, Universite Paris XI, F-91405, Orsay (France)]. E-mail: gilles.maynard@pgp.u-psud.fr; Barriga-Carrasco, M.D. [Laboratoire de Physique des Gaz et des Pasmas, CNRS UMR8578, bat. 210, Universite Paris XI, F-91405, Orsay (France)

    2005-05-21

    Laser Proton Source (LPS) can generate short bunch of energetic protons with a nearly zero initial emittance. It is thus expected that LPS can deposit a very high density of energy inside dense matter, in particular, in the context of fast ignition of an inertial fusion target. We investigate here one of the factors that can limit the density of deposited energy. It concerns the transverse diffusion, occurring during the transport between the LPS and DT. As the rear surface of LPS should be efficiently protected, the proton along its path has to interact with a substantial amount of high-Z material. Therefore the induced transverse dispersion can become significant. The transport of the proton beam inside a plasma target is calculated using a numerical code, which main features are presented.

  1. Determination of 131m Xe and 133m Xe in the presence of 133gXe via combined beta-spectroscopy and delayed coincidence

    International Nuclear Information System (INIS)

    Reeder, Paul L.; Bowyer, Ted W.; McIntyre, Justin I.; Pitts, W K.

    2001-01-01

    The International Monitoring System for the Comprehensive Nuclear-Test-Ban Treaty will include measurements of Xe fission products. Pacific Northwest National Laboratory has developed an automated system for separating Xe from air which detects Xe fission products using a beta-gamma counting system for 131mXe, 133mXe, 133Xe, and 135Xe. Betas and conversion electrons are detected in a plastic scintillation cell containing the Xe sample. Gamma and X-rays are detected in a NaI(Tl) scintillation detector which surrounds the plastic scintillator sample cell. Two-dimensional pulse height spectra of gamma energy versus beta energy are obtained. The plastic scintillator spectrum in coincidence with the 31-keV X-rays from 131mXe. 133mXe, and 133Xe is a complex mixture of conversion electrons and betas. A new technique to simultaneously measure the delayed coincidence (t1/2 = 6.27 ns) between beta particles from 133Xe and conversion electrons depopulating the 81-keV state in 133Cs is being developed. This technique will allow separation of the 133Xe spectrum from the conversion electrons due to 131mXe and 133mXe and will uniquely quantify all three nuclides

  2. On Tuning PI Controllers for Integrating Plus Time Delay Systems

    Directory of Open Access Journals (Sweden)

    David Di Ruscio

    2010-10-01

    Full Text Available Some analytical results concerning PI controller tuning based on integrator plus time delay models are worked out and presented. A method for obtaining PI controller parameters, Kp=alpha/(k*tau, and, Ti=beta*tau, which ensures a given prescribed maximum time delay error, dtau_max, to time delay, tau, ratio parameter delta=dau_max/tau, is presented. The corner stone in this method, is a method product parameter, c=alpha*beta. Analytical relations between the PI controller parameters, Ti, and, Kp, and the time delay error parameter, delta, is presented, and we propose the setting, beta=c/a*(delta+1, and, alpha=a/(delta+1, which gives, Ti=c/a*(delta+1*tau, and Kp=a/((delta+1*k*tau, where the parameter, a, is constant in the method product parameter, c=alpha*beta. It also turns out that the integral time, Ti, is linear in, delta, and the proportional gain, Kp, inversely proportional to, delta+1. For the original Ziegler Nichols (ZN method this parameter is approximately, c=2.38, and the presented method may e.g., be used to obtain new modified ZN parameters with increased robustness margins, also documented in the paper.

  3. Production of high-brightness continuous wave proton beams with very high proton fractions (abstract)a

    International Nuclear Information System (INIS)

    Spence, D.; McMichael, G.; Lykke, K.R.; Schneider, J.D.; Sherman, J.; Stevens, R. Jr.; Hodgkins, D.

    1996-01-01

    This article demonstrates a new technique to significantly enhance the proton fraction of an ion beam extracted from a plasma ion source. We employ a magnetically confined microwave driven source, though the technique is not source specific and can probably be applied equally effectively to other plasma sources such as Penning and multicusp types. Specifically, we dope the plasma with about 1% H 2 O, which increases the proton fraction of a 45 keV 45 mA beam from 75% to 90% with 375 W 2.45 GHz power to the source and from 84% to 92% for 500 W when the source is operated under nonresonant conditions. Much of the remaining fraction of the beam comprises a heavy mass ion we believe to be N + impurity ions resulting from the conditions under which the experiments were performed. If so, this impurity can easily be removed and much higher proton fractions could be expected. Preliminary measurements show the additive has no adverse effect on the emittance of the extracted beam, and source stability is greatly improved

  4. [Comparison of initial and delayed myocardial imaging with beta-methyl-p-[123I]-iodophenylpentadecanoic acid in acute myocardial infarction].

    Science.gov (United States)

    Naruse, H; Yoshimura, N; Yamamoto, J; Morita, M; Fukutake, N; Ohyanagi, M; Iwasaki, T; Fukuchi, M

    1994-01-01

    Myocardial imaging using beta-methyl-p-[123I]-iodophenylpentadecanoic acid (BMIPP) of 15 patients with acute myocardial infarction was performed to assess "fill-in" and "washout" defects in the delayed myocardial image. The initial and delayed images were evaluated by a visual and quantitative washout rate method. Visual judgement found 8/180 (4%) segments showed "fill-in" defects, and 24/180 segments (13%) showed "washout" defects. There was no relationship between days from onset to the study and the frequency of fill-in and washout defects. The mean washout rate in the segments with "fill-in" defects was 9.0 +/- 16.6%, and that of "washout" defects was 24.9 +/- 18.1% which was significantly higher than in controls (8.7 +/- 15.4%, p < 0.05). There was no correlation between mean washout rate and total blood lipids, total cholesterol, triglyceride and HDL-cholesterol. Therefore, neither time from onset nor blood lipids level was related to changes from the initial image to the delayed image. These changes may be due to relative (false) findings due to changes in circumference, and may be based on myocardial characteristics after myocardial infarction and/or reperfusion.

  5. Electric quadrupole moments of {beta}-emitter {sup 21}F and {sup 23}Mg

    Energy Technology Data Exchange (ETDEWEB)

    Onishi, Takashi; Matsuta, Kensaku; Fukuda, Mitsunori [Osaka Univ., Toyonaka (Japan). Faculty of Science] [and others

    1997-03-01

    For the systematic study of nuclear electromagnetic moments, electric quadrupole moments Q of {beta}-emitting nuclei {sup 21}F and {sup 23}Mg have been measured for the first time through combined technique of the polarized nuclear beams and {beta}-NMR technique. From the quadrupole coupling constants of {sup 21}F and {sup 23}Mg in MgF{sub 2} single crystal, the ratios of the Q`s with the known Q were determined as |Q({sup 21}F)|/|Q({sup 19}F{sup *})|=1.001{+-}0.034 and |Q({sup 23}Mg)|/|Q({sup 25}Mg)|=0.571{+-}0.017. (author)

  6. Advances in the helium-jet coupled on-line mass seperator RAMA

    International Nuclear Information System (INIS)

    Moltz, D.M.; Aeystoe, J.; Cable, M.D.; Parry, R.F.; Haustein, P.E.; Wouters, J.M.; Cerny, J.; California Univ., Berkeley

    1981-01-01

    General improvements to the on-line mass separator RAMA have yielded a greater reliability and efficiency for some elements. A new utilitarian helium-jet chamber has been installed to facilitate quick target and degrader foil changes in addition to a new ion source holder. A higher efficiency hollow-cathode, cathode-extraction ion source for lower melting point elements ( 0 C) has also been designed. Tests with the beta-delayed proton emitter 37 Ca showed a factor of five increase in yield over the old hollow-cathode, anode-extraction source. A differentially-pumped tape drive system compatible with both γ-γ and β-γ experiments has been incorporated into the general detection system. All major operating parameters will soon be monitored by a complete stand-alone microprocessor system which will eventually be upgraded to a closed-loop control system. (orig.)

  7. Advances in the helium-jet coupled on-line mass separator RAMA

    International Nuclear Information System (INIS)

    Moltz, D.M.; Aysto, J.; Cable, M.D.; Parry, R.F.; Haustein, P.E.; Wouters, J.M.; Cerny, J.

    1980-01-01

    General improvements to the on-line mass separator RAMA (Recoil Atom Mass Analyzer) have yielded a greater reliability and efficiency for some elements. A new utilitarian helium-jet chamber has been installed to facilitate quick target and degrader foil changes in addition to a new ion source holder. A higher efficiency hollow-cathode, cathode-extraction ion source, for lower melting point elements ( 0 C) has also been designed. Tests with the beta-delayed proton emitter 37 Ca showed a factor of five increase in yield over the old hollow-cathode, anode-extraction source. A differentially-pumped-tape drive system compatible with both γ-γ and β-γ experiments has been incorporated into the general detection system. All major operating parameters will soon be monitored by a complete stand-alone microprocessor system which will eventually be upgraded to a closed-loop control system

  8. High brightness fiber laser pump sources based on single emitters and multiple single emitters

    Science.gov (United States)

    Scheller, Torsten; Wagner, Lars; Wolf, Jürgen; Bonati, Guido; Dörfel, Falk; Gabler, Thomas

    2008-02-01

    Driven by the potential of the fiber laser market, the development of high brightness pump sources has been pushed during the last years. The main approaches to reach the targets of this market had been the direct coupling of single emitters (SE) on the one hand and the beam shaping of bars and stacks on the other hand, which often causes higher cost per watt. Meanwhile the power of single emitters with 100μm emitter size for direct coupling increased dramatically, which also pushed a new generation of wide stripe emitters or multi emitters (ME) of up to 1000μm emitter size respectively "minibars" with apertures of 3 to 5mm. The advantage of this emitter type compared to traditional bars is it's scalability to power levels of 40W to 60W combined with a small aperture which gives advantages when coupling into a fiber. We show concepts using this multiple single emitters for fiber coupled systems of 25W up to 40W out of a 100μm fiber NA 0.22 with a reasonable optical efficiency. Taking into account a further efficiency optimization and an increase in power of these devices in the near future, the EUR/W ratio pushed by the fiber laser manufacturer will further decrease. Results will be shown as well for higher power pump sources. Additional state of the art tapered fiber bundles for photonic crystal fibers are used to combine 7 (19) pump sources to output powers of 100W (370W) out of a 130μm (250μm) fiber NA 0.6 with nominal 20W per port. Improving those TFB's in the near future and utilizing 40W per pump leg, an output power of even 750W out of 250μm fiber NA 0.6 will be possible. Combined Counter- and Co-Propagated pumping of the fiber will then lead to the first 1kW fiber laser oscillator.

  9. Emittance reconstruction technique for the Linac4 high energy commissioning

    CERN Document Server

    Lallement, JB; Posocco, PA

    2012-01-01

    Linac4 is a new 160 MeV linear accelerator for negative Hydrogen ions (H-) presently under construction which will replace the 50 MeV proton Linac2 as injector for the CERN proton accelerator complex. Linac4 is 80 meters long and comprises a Low Energy Beam Transport line, a 3 MeV RFQ, a MEBT, a 50 MeV DTL, a 100 MeV CCDTL and a PIMS up to 160 MeV. The commissioning of the Linac is scheduled to start in 2013. It will be divided into several steps corresponding to the commissioning of the different accelerating structures. A temporary measurement bench will be dedicated to the high energy commissioning from 30 to 100 MeV (DTL tanks 2 and 3, and CCDTL). The commissioning of the PIMS will be done using the permanent equipment installed in between the end of the Linac and the main dump. This note describes the technique we will use for reconstructing the transverse emittances and the expected results.

  10. Simulation of turn-by-turn passage of protons through the H-minus stripping foil in booster

    Energy Technology Data Exchange (ETDEWEB)

    Gardner, C. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2017-07-06

    Equations for transverse emittance growth due to multiple passes of circulating proton beam through the H-minus stripping foil in Booster were developed in [1]. These were based on simple principles of statistics and simple assumptions about the initial distribution of particles incident on the foil. It was assumed there that the foil dimensions and position of the incoming beam are such that all particles hit the foil on every turn around the machine. In the present note we assume only that all incoming H-minus ions from Linac hit the foil and are stripped of their electrons. The resulting protons circulate indefinitely around the machine. Setups in which the foil width is reduced so that not all protons hit the foil on every turn are studied here by simulation. The aim is to determine the effectiveness of such setups in reducing the emittance growth of circulating proton beam during the injection of H-minus beam. The simulations also serve as a check of the equations developed in [1], and vice versa. The particulars of the simulation setup are given in Sections 1 through 11. Figures 1 through 12 show simulation results for the case in which all particles hit the foil on every turn. The results are in good agreement with those obtained from the equations of reference [1]. Figures 13 through 19 show simulation results for various setups in which the foil width is reduced. These results are summarized in Section 12. In all gures the horizontal axis gives the turn number. The unit of the vertical axis is micrometers ( m) in all plots of emittance.

  11. Low emittance electron storage rings

    Science.gov (United States)

    Levichev, E. B.

    2018-01-01

    Low-emittance electron (positron) beams are essential for synchrotron light sources, linear collider damping rings, and circular Crab Waist colliders. In this review, the principles and methods of emittance minimization are discussed, prospects for developing relativistic electron storage rings with small beam phase volume are assessed, and problems related to emittance minimization are examined together with their possible solutions. The special features and engineering implementation aspects of various facilities are briefly reviewed.

  12. Accounting for beta-particle energy loss to cortical bone via paired-image radiation transport (PIRT)

    International Nuclear Information System (INIS)

    Shah, Amish P.; Rajon, Didier A.; Patton, Phillip W.; Jokisch, Derek W.; Bolch, Wesley E.

    2005-01-01

    Current methods of skeletal dose assessment in both medical physics (radionuclide therapy) and health physics (dose reconstruction and risk assessment) rely heavily on a single set of bone and marrow cavity chord-length distributions in which particle energy deposition is tracked within an infinite extent of trabecular spongiosa, with no allowance for particle escape to cortical bone. In the present study, we introduce a paired-image radiation transport (PIRT) model which provides a more realistic three-dimensional (3D) geometry for particle transport in the skeletal site at both microscopic and macroscopic levels of its histology. Ex vivo CT scans were acquired of the pelvis, cranial cap, and individual ribs excised from a 66-year male cadaver (BMI of 22.7 kg m -2 ). For the three skeletal sites, regions of trabecular spongiosa and cortical bone were identified and segmented. Physical sections of interior spongiosa were taken and subjected to microCT imaging. Voxels within the resulting microCT images were then segmented and labeled as regions of bone trabeculae, endosteum, active marrow, and inactive marrow through application of image processing algorithms. The PIRT methodology was then implemented within the EGSNRC radiation transport code whereby electrons of various initial energies are simultaneously tracked within both the ex vivo CT macroimage and the CT microimage of the skeletal site. At initial electron energies greater than 50-200 keV, a divergence in absorbed fractions to active marrow are noted between PIRT model simulations and those estimated under existing techniques of infinite spongiosa transport. Calculations of radionuclide S values under both methodologies imply that current chord-based models may overestimate the absorbed dose to active bone marrow in these skeletal sites by 0% to 27% for low-energy beta emitters ( 33 P, 169 Er, and 177 Lu), by ∼4% to 49% for intermediate-energy beta emitters ( 153 Sm, 186 Re, and 89 Sr), and by ∼14% to

  13. Modified theoretical minimum emittance lattice for an electron storage ring with extreme-low emittance

    Directory of Open Access Journals (Sweden)

    Yi Jiao

    2011-05-01

    Full Text Available In the continuing efforts to reduce the beam emittance of an electron storage ring composed of theoretical minimum emittance (TME lattice, down to a level of several tens of picometers, nonlinear dynamics grows to be a great challenge to the performance of the storage ring because of the strong sextupoles needed to compensate for its large global natural chomaticities coupled with its small average dispersion function. To help in dealing with the challenge of nonlinear optimization, we propose a novel variation of theoretical minimum emittance (TME lattice, named as “modified-TME” lattice, with minimal emittance about 3 times of the exact theoretical minimum, while with more compact layout, lower phase advance per cell, smaller natural chromaticities, and more relaxed optical functions than that in a TME cell, by using horizontally defocusing quadrupole closer to the dipole or simply combined-function dipole with horizontally defocusing gradient. We present approximate scaling formulas to describe the relationships of the design parameters in a modified-TME cell. The applications of modified-TME lattice in the PEP-X storage ring design are illustrated and the proposed lattice appears a good candidate for synchrotron radiation light source with extremely low emittance.

  14. Delayed neutron emission near the shell-closures

    Directory of Open Access Journals (Sweden)

    Borzov Ivan

    2016-01-01

    Full Text Available The self-consistent Density Functional + Continuum QRPA approach (DF+CQRPA provides a good description of the recent experimental beta-decay half-lives and delayed neutron emission branchings for the nuclei approaching to (and beyond the neutron closed shells N = 28; 50; 82. Predictions of beta-decay properties are more reliable than the ones of standard global approaches traditionally used for the r-process modelling. An impact of the quasi-particle phonon coupling on the delayed multi-neutron emission rates P2n, P3n,… near the closed shells is also discussed.

  15. A device for electron gun emittance measurement

    International Nuclear Information System (INIS)

    Aune, B.; Corveller, P.; Jablonka, M.; Joly, J.M.

    1985-05-01

    In order to improve the final emittance of the beam delivered by the ALS electron linac a new gun is going to be installed. To measure its emittance and evaluate the contribution of different factors to emittance growth we have developed an emittance measurement device. We describe the experimental and mathematical procedure we have followed, and give some results of measurements

  16. Studies of internal bremsstrahlung spectrum of 35S beta emitter in the photon energy region of 1–100 keV

    International Nuclear Information System (INIS)

    Singh, Amrit; Dhaliwal, A.S.

    2014-01-01

    The internal bremsstrahlung (IB) spectral photon distribution, produced by soft beta particles of 35 S (W max =164 keV), in the photon energy region of 1–100 keV, is measured by using a Si(Li) detector, having high energy resolution and efficiency at low energy region. The measured spectral IB photon distribution is compared with KUB theory and Coulomb corrected IB theories given by Nilsson, and Lewis and Ford. After applying the necessary corrections, the experimental and theoretical IB spectral photon distributions are compared in terms of the number of IB photon of energy k per m o c 2 per unit photon yield. In the low energy region (below 10 keV), the experimental results are in agreement with all the theories. However, in photon energy region of 10–50 keV, experimental results are in agreement with Coulomb corrected Nilsson theory only, within the experimental errors. Further, beyond 50 keV, the Nilsson theory is more close to the experimental results than the KUB, and the Lewis and Ford theories. Hence, the Nilsson theory is more accurate than the other theories given by KUB and Lewis and Ford, particularly at a high energy end. The experimental results reported here with Si(Li) detector are free from number of ambiguities in earlier measurements reported with NaI(Tl) and HPGe detectors. The present results are indicating a relook into the theoretical considerations, given by different theories, while taking into account the Coulomb corrections for predicting the IB spectrum, particularly at high photon energy region. - Highlights: • The internal bremsstrahlung spectrum of 35 S beta emitter, in the photon energy region of 1–100 keV. • These measurement are taken by using a Si(Li) detector. • Theoretical and experimental results are reported in terms of number of photons of energy k per m 0 c 2 per unit photon yield. • The Nilsson theory for IB is more accurate than KUB and Lewis and Ford, particularly at high photon energy region

  17. 4{pi} proportional counter for absolute measurement of {beta}-emitters; Compteur 4{pi} proportionnel destine a la mesure absolue d'emetteurs {beta}

    Energy Technology Data Exchange (ETDEWEB)

    Perolat, J P; Laine, M [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-07-01

    The 4{pi} counter is commonly used to measure the activity of {beta} sources, the one we describe does not advance a new conception but the issue of several years of investigations. The apparatus presents good performances about the qualities commonly required in that kind of counter: detection efficiency, plateau and dead time. Moreover technical characteristics give a great flexibility in use, particularly a possibility of adaptation in a {beta},{gamma} coincidence unit. (authors) [French] Le compteur 4{pi} proportionnel est couramment, utilise pour mesurer l'activite de sources {beta}, celui que nous decrivons ne represente pas une conception nouvelle, mais plutot l'aboutissement de plusieurs annees d'etudes. Cette installation presente des performances satisfaisantes en ce qui concerne les qualites habituellement requises dans ce type de compteur: l'efficacite de detection, le palier et le temps mort. En outre, certaines caracteristiques techniques qui lui sont propres lui conferent une grande souplesse d'utilisation, en particulier la possibilite d'adaptation a un ensemble de mesures par coincidences 4{pi} {beta} {gamma}. (auteurs)

  18. Study of Beta-Delayed Neutron Emission by Neutron-Rich Nuclei and Analysis of the Nuclear Reaction Mechanism responsible for the Yields of these Nuclei

    International Nuclear Information System (INIS)

    Bazin, D.

    1987-07-01

    Among the nuclear mechanisms used for the production of nuclei far from stability, the projectile fragmentation process has recently proved its efficiency. However, at Fermi energies, one has to take into account some collective and relaxation effects which drastically modify the production cross-sections. The spectroscopic study of very neutron-rich nuclei is very dependent of these production rates. A study of beta-delayed neutron emission which leads to new measurements of half-lives and neutron delayed emission probabilities is achieved with a liquid scintillator detector. The results which are then compared to different theories are of interest for the understanding of natural production of heavy elements (r processus) [fr

  19. Multiwire secondary-emission monitor and the emittance measurement of the AGS beam

    International Nuclear Information System (INIS)

    Weng, W.T.; Chiang, I.H.; Smith, G.A.; Soukas, A.

    1983-01-01

    For CBA injection the transverse emittances and the Twiss parameters of the AGS beam have to be well defined to minimize the phase space dilution in CBA. Althoug there exists a profile monitor device at U165, there are three reasons why construction of multiwire profile monitor system at three locations from U500 to U168 is required: (1) the dispersion function is not zero at U165 which makes it harder to interpret the measurement; (2) the original single wire device takes five minutes to traverse the whole beam; (3) a three station multiwire system can provide the profile information at all locations in one pulse which makes on-line analysis possible. In summary, a set of three stations of Multiwire Secondary Emission Monitor (MSEM) has been built and installed in the fast external beam line for the measurement of beam profiles. Each unit consists of two planes each with 30 nickel wires having a diameter of 5 mils. The signal is linear within the range of 10 10 to 10 13 incident protons on the wire and the resolution of the signal is well within a few percent. A least-square fitting routine has been used to extract the emittance and phase space parameters of the beam. The emittances obtained at various intensities will help us to understand the AGS acceleration process and to choose the optimal injection scheme for CBA

  20. Enhanced proton acceleration by intense laser interaction with an inverse cone target

    International Nuclear Information System (INIS)

    Bake, Muhammad Ali; Aimidula, Aimierding; Xiaerding, Fuerkaiti; Rashidin, Reyima

    2016-01-01

    The generation and control of high-quality proton bunches using focused intense laser pulse on an inverse cone target is investigated with a set of particle-in-cell simulations. The inverse cone is a high atomic number conical frustum with a thin solid top and open base, where the laser impinges onto the top surface directly, not down the open end of the cone. Results are compared with a simple planar target, where the proton angular distribution is very broad because of transverse divergence of the electromagnetic fields behind the target. For a conical target, hot electrons along the cone wall surface induce a transverse focusing sheath field. This field can effectively suppress the spatial spreading of the protons, resulting in a high-quality small-emittance, low-divergence proton beam. A slightly lower proton beam peak energy than that of a conventional planar target was also found.

  1. Enhanced proton acceleration by intense laser interaction with an inverse cone target

    Energy Technology Data Exchange (ETDEWEB)

    Bake, Muhammad Ali; Aimidula, Aimierding, E-mail: amir@mail.bnu.edu.cn; Xiaerding, Fuerkaiti; Rashidin, Reyima [School of Physics Science and Technology, Xinjiang University, Urumqi 830046 (China)

    2016-08-15

    The generation and control of high-quality proton bunches using focused intense laser pulse on an inverse cone target is investigated with a set of particle-in-cell simulations. The inverse cone is a high atomic number conical frustum with a thin solid top and open base, where the laser impinges onto the top surface directly, not down the open end of the cone. Results are compared with a simple planar target, where the proton angular distribution is very broad because of transverse divergence of the electromagnetic fields behind the target. For a conical target, hot electrons along the cone wall surface induce a transverse focusing sheath field. This field can effectively suppress the spatial spreading of the protons, resulting in a high-quality small-emittance, low-divergence proton beam. A slightly lower proton beam peak energy than that of a conventional planar target was also found.

  2. Observation and Study of Proton Aurora by using Scanning Photometer

    Science.gov (United States)

    Mochizuki, T.; Ono, T.; Kadokura, A.; Sato, N.

    2009-12-01

    The proton auroras have significant differences from electron auroras in their spectral shape. They show Doppler-shifted and broadened spectra: the spectra have Doppler-shifted (~0.5 nm shorter) peak and both bluewing (~2-4 nm) and redwing (~1.5 nm) extending. Energy spectra of precipitating protons have been estimated from this shape. Recently it is found that the intensity in the extent of the blue wing reflects more effectively by the change of the mean energy of precipitating protons than the shift of peak wavelength [Lanchester et al., 2003]. Another character of the H-beta aurora is that it is diffuse form because a proton becomes hydrogen atom due to a charge-exchange reaction with atmospheric constituent and then possible to move across the magnetic field line. By using a scanning photometer, the movement of the proton auroral belt and change of a spectrum shape associated with the variation of proton source region due to storm and substorm were reported, however, not discussed in detail yet [Deehr and Lummerzheim, 2001]. The purpose of this study is to obtain the detail characteristics of H-beta aurora for understanding of source region of energetic protons in the magnetosphere. For this purpose, a new meridian-scanning photometer (SPM) was installed at Husafell station in Iceland in last summer season and Syowa Station, Antarctica. It will contribute to investigate the distribution of energetic protons and plasma waves which cause the pitch angle scattering in the magnetosphere. The meridian-scanning photometer is able to observe at five wavelengths for H-beta emission. One channel is to measure the background level. By analyzing the data obtained by the SPM, the H-beta spectrum can be estimated by fitting a model function with it. Then it is possible to obtain distribution of precipitating protons in north-south direction. It is also possible to estimate an energy spectrum of precipitating proton, simultaneously. The instrumental parameters of the SPM is

  3. Resonant beam behavior studies in the Proton Storage Ring

    Directory of Open Access Journals (Sweden)

    S. Cousineau

    2003-07-01

    Full Text Available We present studies of space-charge-induced beam profile broadening at high intensities in the Proton Storage Ring (PSR at Los Alamos National Laboratory. We investigate the profile broadening through detailed particle-in-cell simulations of several experiments and obtain results in good agreement with the measurements. We interpret these results within the framework of coherent resonance theory. With increasing intensity, our simulations show strong evidence for the presence of a quadrupole-mode resonance of the beam envelope with the lattice in the vertical plane. Specifically, we observe incoherent tunes crossing integer values, and large amplitude, nearly periodic envelope oscillations. At the highest operating intensities, we observe a continuing relaxation of the beam through space charge forces leading to emittance growth. The increase of emittance commences when the beam parameters encounter an envelope stop band. Once the stop band is reached, the emittance growth balances the intensity increase to maintain the beam near the stop band edge. Additionally, we investigate the potential benefit of a stop band correction to the high intensity PSR beam.

  4. Positioning in a flat two-dimensional space-time: The delay master equation

    International Nuclear Information System (INIS)

    Coll, Bartolome; Ferrando, Joan Josep; Morales-Lladosa, Juan Antonio

    2010-01-01

    The basic theory on relativistic positioning systems in a two-dimensional space-time has been presented in two previous papers [B. Coll, J. J. Ferrando, and J. A. Morales, Phys. Rev. D 73, 084017 (2006); ibid.74, 104003 (2006)], where the possibility of making relativistic gravimetry with these systems has been analyzed by considering specific examples. Here, generic relativistic positioning systems in the Minkowski plane are studied. The information that can be obtained from the data received by a user of the positioning system is analyzed in detail. In particular, it is shown that the accelerations of the emitters and of the user along their trajectories are determined by the sole knowledge of the emitter positioning data and of the acceleration of only one of the emitters. Moreover, as a consequence of the so-called master delay equation, the knowledge of this acceleration is only required during an echo interval, i.e., the interval between the emission time of a signal by an emitter and its reception time after being reflected by the other emitter. These results are illustrated with the obtention of the dynamics of the emitters and of the user from specific sets of data received by the user.

  5. Part I: $\\beta$-delayed fission, laser spectroscopy and shape-coexistence studies with astatine beams; Part II: Delineating the island of deformation in the light gold isotopes by means of laser spectroscopy

    CERN Document Server

    Andreyev, Andrei

    2013-01-01

    Part I: $\\beta$-delayed fission, laser spectroscopy and shape-coexistence studies with astatine beams; Part II: Delineating the island of deformation in the light gold isotopes by means of laser spectroscopy

  6. Search for Long-Lived Neutral Particles in Final States with Delayed Photon and Missing Transverse Energy from Proton-Proton Collisions Using the CMS detector

    Science.gov (United States)

    Tambe Ebai, Norbert

    We perform a search for long-lived neutral particles in final state with delayed photons and large missing transverse energy produced in LHC proton-proton collisions at center-of-mass energy, √s = 8 TeV. Capitalizing on the excellent timing resolution of the CMS Electromagnetic Calorimeter the search uses photon time measurements made by the Electromagnetic Calorimeter as the main search quantity. We found a single event consistent with our background expectations from the Standard Model and set a model-independent upper limit of 4.37 on number of signal events. We also interpret our results in the context of the SPS8 benchmark GMSB model and show that neutralinos with mean lifetime, tau PSneutralinoOne ≤ 45 ns, and mass, mPSneutralinoOne ≤ 300 GeV/c2, or effective Supersymmetry breaking energy scale, Lambda ≤ 220TeV, are ruled out of existence at 95% CLS confidence level. The exclusion limit on the product of the production cross-section and branching ratio of the neutralino to photon and gravitino decay channel, sigma(PSneutralinoOne → gamma + G˜) x BR, for different lifetimes and masses is derived. Our results confirm for the first time that the CMS Electromagnetic Calorimeter provides good sensitivity to search for long-lived neutral particles with lifetimes up to 40 ns and masses up to 300 GeV/c2 using only timing measurements.

  7. Study of the time and space distribution of β+ emitters from 80MeV/u carbon ion beam irradiation on PMMA

    International Nuclear Information System (INIS)

    Agodi, C.; Bellini, F.; Cirrone, G.A.P.; Collamati, F.; Cuttone, G.; De Lucia, E.; De Napoli, M.; Di Domenico, A.; Faccini, R.; Ferroni, F.; Fiore, S.; Gauzzi, P.; Iarocci, E.; Marafini, M.; Mattei, I.; Paoloni, A.

    2012-01-01

    Proton and carbon ion therapy is an emerging technique used for the treatment of solid cancers. The monitoring of the dose delivered during such treatments and the on-line knowledge of the Bragg peak position is still a matter of research. A possible technique exploits the collinear 511keV photons produced by positrons annihilation from β + emitters created by the beam. This paper reports rate measurements of the 511keV photons emitted after the interactions of a 80MeV/u fully stripped carbon ion beam at the Laboratori Nazionali del Sud (LNS) of INFN, with a poly-methyl methacrylate target. The time evolution of the β + rate was parametrized and the dominance of 11 C emitters over the other species ( 13 N, 15 O, 14 O) was observed, measuring the fraction of carbon ions activating β + emitters to be (10.3±0.7)×10 -3 . The average depth in the PMMA of the positron annihilation from β + emitters was also measured, D β + =5.3±1.1mm, to be compared to the expected Bragg peak depth D Bragg =11.0±0.5mm obtained from simulations.

  8. Diamond-based single-photon emitters

    International Nuclear Information System (INIS)

    Aharonovich, I; Castelletto, S; Simpson, D A; Su, C-H; Greentree, A D; Prawer, S

    2011-01-01

    The exploitation of emerging quantum technologies requires efficient fabrication of key building blocks. Sources of single photons are extremely important across many applications as they can serve as vectors for quantum information-thereby allowing long-range (perhaps even global-scale) quantum states to be made and manipulated for tasks such as quantum communication or distributed quantum computation. At the single-emitter level, quantum sources also afford new possibilities in terms of nanoscopy and bio-marking. Color centers in diamond are prominent candidates to generate and manipulate quantum states of light, as they are a photostable solid-state source of single photons at room temperature. In this review, we discuss the state of the art of diamond-based single-photon emitters and highlight their fabrication methodologies. We present the experimental techniques used to characterize the quantum emitters and discuss their photophysical properties. We outline a number of applications including quantum key distribution, bio-marking and sub-diffraction imaging, where diamond-based single emitters are playing a crucial role. We conclude with a discussion of the main challenges and perspectives for employing diamond emitters in quantum information processing.

  9. Measurement of the activity of beta emitting gases using an ionisation chamber; Mesure de l'activite des gaz emetteurs beta au moyen d'une chambre d'ionisation

    Energy Technology Data Exchange (ETDEWEB)

    Lebouleux, P [Commissariat a l' Energie Atomique. Centre d' Etudes Nucleaires de Saclay, 91 - Gif-sur-Yvette (France)

    1962-07-01

    An ionization chamber was developed for measuring directly the activity of a {beta}-emitting gas whatever the gas may be. The following two parameters are defined and determined: p, the average specific ionization produced by a {beta} disintegration, and i, the average {beta} path in the chamber. It was shown, during the determination of i, that the {beta} particles are reflected on the walls of the ionization chamber when the latter are made of a high atomic number material. It was possible to eliminate this effect by constructing an electrode chamber made of graphite. With this chamber a direct measurement can be made of the activity of a gaseous {beta} emitter with a precision of about {+-}10%. Some applications are given of the graphite electrode chamber (calibration of the chambers built industrially and determination of the activation cross section of a gaseous emitter). It was possible to determine the activation cross section of {sup 134}Xe; a value of 0.18 {+-} 0.03 barn was found. (author) [French] Le but de l'etude est de realiser une chambre d'ionisation permettant d'effectuer une mesure directe de l'activite d'un gaz emetteur {beta} quel que soit l'emetteur considere. On definit et l'on determine les deux parametres suivants: p: ionisation specifique moyenne produite par une desintegration {beta}. La determination est effectuee par une methode graphique, i: moyenne des parcours des {beta} dans la chambre. La determination est effectuee experimentalement par introduction dans la chambre d'un gaz radioactif dont on peut calculer l'activite. On a mis en evidence, au cours de la determination de i, la reflexion des particules {beta} sur les parois des chambres d'ionisation lorsque celles-ci sont constituees d'un materiau de numero atomique eleve. La construction d'une chambre a electrodes de graphite nous a permis d'eliminer ce phenomene. Avec cette chambre, on effectue une mesure directe de l'activite d'un emetteur {beta} gazeux avec une precision de l

  10. The Fermilab Collider D/Phi/ low BETA system

    Energy Technology Data Exchange (ETDEWEB)

    McInturff, A.D.; Carson, J.; Collins, T.; Koepke, K.; Malamud, E.; Mantsch, P.; Niemann, R.; Riddiford, A.

    1988-06-01

    A new low BETA system has been designed to serve the detector facility under construction at the D/Phi/ location of the Fermilab Superconducting Collider. The low BETA system consists of 18 special cold iron quadrupoles powered as 11 independent circuits that can adjust the BETA value at the intersection point down to 25 cm. Low beta is achieved with a set of 1.4 T/cm, two shell, high current quadrupoles. Smaller 0.7 T/cm, single shell trim quadrupoles are used to match the low beta insertion to the rest of the accelerator lattice. Gaps have been left in the lattice for electrostatic separators to separate the proton and antiproton beams everywhere except at the desired collision points. 6 refs., 6 figs., 3 tabs.

  11. Emittance compensation of CW DC-gun photoinjector

    International Nuclear Information System (INIS)

    Li Peng; Wu Dai; Xu Zhou; Li Ming; Yang Xingfan

    2011-01-01

    Emittance growth induced by space charge effect is very important, especially for CW DC-gun photoinjector. In this work, the linear space charge force and its effect on electron beam transverse emittance are studied, and the principle and properties of emittance compensation by solenoid are analyzed. The CAEP DC-gun photoinjector with a solenoid is also simulated by code Parmela. Simulated results indicate that the normalized transverse emittance of an 80 pC bunch at the 350 keV DC-gun ex-it is 5.14 mm · mrad. And after compensated by a solenoid, it becomes 1.27 mm · mrad. The emittance of beam is well compensated. (authors)

  12. A low-emittance lattice for SPEAR

    International Nuclear Information System (INIS)

    Safranek, J.; Wiedemann, H.

    1992-01-01

    The design and implementation of a low emittance lattice for the SPEAR storage ring including measurements of the performance of the lattice are presented (J. Safranek, Ph. D. thesis, Stanford University, 1991). The low emittance lattice is designed to optimize the performance of SPEAR as a synchrotron radiation source while keeping SPEAR hardware changes at a minimum. The horizontal emittance of the electron beam in the low emittance lattice is reduced by a factor of 4 from the previous lattice. This reduces the typical horizontal source size and divergence of the photon beams by a factor of 2 each and increases the photon beam brightness. At 3 GeV the horizontal emittance is 129 π nm rad, which makes the low emittance lattice the lowest emittance, runnning synchroton radiation source in the world in the 1.5 to 4.0 GeV energy range for the emittance scaled to 3 GeV. The measured vertical emittance was reduced to half that typically seen at SPEAR in the past. The brightness of the photon beams was further incrased by reducing β y at the insertion devices to 1.1 m and reducing the energy dispersion at the insertion devices by more than a factor of 2 on average. The horizontal despersion at the rf cavities was reduced by a factor of nearly 4 which gives much less problems with synchrobetatron resonances. The dynamic and physical apertures of the lattice are large, giving long beam lifetimes and easy injection of electrons. The measurements of the linear optics and intensity dependent phenomena gave resonable agreement with the design . The overall performance of the machine was very good. Injection rates of 10 to 20 mA/min and larger were achieved routinely, and 100 mA total current was stored. Repeated ramping of stored beam from the injection energy of 2.3 GeV to the running energy of 3.0 GeV was achieved with very little beam loss. This low emittance configuration is expected to be the operating configuration for SPEAR starting in January 1992. (orig.)

  13. Space-Charge Experiments at the CERN Proton Synchrotron

    CERN Document Server

    Franchetti, Giuliano; Hofmann, I; Martini, M; Métral, E; Qiang, J; Ryne, D; Steerenberg, R; CFA Beam Dynamics Workshop “High Intensity and Brightness Hadron Beams”

    2005-01-01

    Benchmarking of the simulation codes used for the design of the next generation of high beam power accelerators is of paramount importance due to the very demanding requirements on the level of beam losses. This is usually accomplished by comparing simulation results against available theories, and more importantly, against experimental observations. To this aim, a number of well-defined test cases, obtained by accurate measurements made in existing machines, are of great interest. Such measurements have been made in the CERN Proton Synchrotron to probe three space-charge effects: (i) transverse emittance blow-up due to space-charge induced crossing of the integer or half-integer stop-band, (ii) space-charge and octupole driven resonance trapping, and (iii) intensity-dependent emittance transfer between the two transverse planes. The last mechanism is discussed in detail in this paper and compared to simulation predictions.

  14. Radiation emitter-detector package

    International Nuclear Information System (INIS)

    O'Brien, J.T.; Limm, A.C.; Nyul, P.; Tassia, V.S. Jr.

    1978-01-01

    Mounted on the metallic base of a radiation emitter-detector is a mounting block is a first projection, and a second projection. A radiation detector is on the first projection and a semiconductor electroluminescent device, i.e., a radiation emitter, is on the second projection such that the plane of the recombination region of the electroluminescent device is perpendicular to the radiation incident surface of the radiation detector. The electroluminescent device has a primary emission and a secondary emission in a direction different from the primary emission. A radiation emitter-detector package as described is ideally suited to those applications wherein the secondary radiation of the electroluminescent device is fed into a feedback circuit regulating the biasing current of the electroluminescent device

  15. Emittance investigation of RF photo-injector

    CERN Document Server

    Yang Mao Rong; Li Zheng; Li Ming; Xu Zhou

    2002-01-01

    A high-power laser beam illuminates a photocathode surface placed on an end wall of an RF cavity. The emitted electrons are accelerated immediately to a relativistic energy by the strong RF find in the cavity. But space charge effect induces beam emittance growth especially near the cathode where the electrons are still nonrelativistic. The author analyzes the factors which lead the transverse emittance growth and method how to resolve this problem. After introducing solenoidal focusing near the photocathode, the beam emittance growth is suppressed dramatically. The beam emittance is given also after compensation and simulation results. The measurements show these results are coincident

  16. Criteria for emittance compensation in high-brightness photoinjectors

    Directory of Open Access Journals (Sweden)

    Chun-xi Wang

    2007-10-01

    Full Text Available A critical process in high-brightness photoinjectors is emittance compensation, which brings under control the correlated transverse emittance growth due to the linear space-charge force. Although emittance compensation has been used and studied for almost two decades, the exact criteria to achieve emittance compensation is not as clear as it should be. In this paper, a perturbative analysis of slice envelopes and emittance evolution close to any reference envelope is developed, via which space-charge and chromatic effects are investigated. A new criterion for emittance compensation is found, which is complementary to the well-known matching condition for the invariant envelope and agrees very well with simulations.

  17. Lactam hydrolysis catalyzed by mononuclear metallo-beta-lactamases: A density functional study

    DEFF Research Database (Denmark)

    Hemmingsen, Lars Bo Stegeager; Olsen, L.; Antony, J.

    2003-01-01

    Two central steps in the hydrolysis of lactam antibiotics catalyzed by mononuclear metallo-beta-lactamases, formation of the tetrahedral intermediate and its breakdown by proton transfer, are studied for model systems using the density functional B3LYP method. Metallo-beta-lactamases have two metal...

  18. Sizeable beta-strength in 31Ar (beta 3p) decay

    DEFF Research Database (Denmark)

    T. Koldste, G.; Blank, B.; J. G. Borge, M.

    2014-01-01

    We present for the first time precise spectroscopic information on the recently discovered decay mode beta-delayed 3p-emission. The detection of the 3p events gives an increased sensitivity to the high energy part of the Gamow-Teller strength distribution from the decay of 31Ar revealing that as ...... that as much as 30% of the strength resides in the beta-3p decay mode. A simplified description of how the main decay modes evolve as the excitation energy increases in 31Cl is provided....

  19. A formula for half-life of proton radioactivity

    Science.gov (United States)

    Zhang, Zhi-Xing; Dong, Jian-Min

    2018-01-01

    We present a formula for proton radioactivity half-lives of spherical proton emitters with the inclusion of the spectroscopic factor. The coefficients in the formula are calibrated with the available experimental data. As an input to calculate the half-life, the spectroscopic factor that characterizes the important information on nuclear structure should be obtained with a nuclear many-body approach. This formula is found to work quite well, and in better agreement with experimental measurements than other theoretical models. Therefore, it can be used as a powerful tool in the investigation of proton emission, in particular for experimentalists. Supported by National Natural Science Foundation of China (11435014, 11405223, 11675265, 11575112), the 973 Program of China (2013CB834401, 2013CB834405), National Key Program for S&T Research and Development (2016YFA0400501), the Knowledge Innovation Project (KJCX2-EW-N01) of Chinese Academy of Sciences, the Funds for Creative Research Groups of China (11321064) and the Youth Innovation Promotion Association of Chinese Academy of Sciences

  20. Small horizontal emittance in the TESLA damping ring

    International Nuclear Information System (INIS)

    Decking, W.

    2001-01-01

    The present TESLA damping ring is designed for a normalized horizontal emittance of 8x10 -6 m. γ-γ collisions at the TESLA linear collider will benefit from a further decrease of the horizontal emittance. This paper reviews the processes which limit the horizontal emittance in the damping ring. Preliminary estimates on the smallest horizontal emittance for the present TESLA damping ring design as well as an ultimate limit of the emittance reachable with the TESLA damping ring concept will be given

  1. Simulation and quasilinear theory of proton firehose instability

    Energy Technology Data Exchange (ETDEWEB)

    Seough, Jungjoon [Korean Astronomy and Space Science Institute, Daejeon (Korea, Republic of); Faculty of Human Development, University of Toyama, 3190, Gofuku, Toyama City, Toyama, 930-8555 (Japan); Yoon, Peter H. [University of Maryland, College Park, Maryland 20742 (United States); School of Space Research, Kyung Hee University, Yongin, Gyeonggi 446-701 (Korea, Republic of); Hwang, Junga [Korean Astronomy and Space Science Institute, Daejeon (Korea, Republic of); Korea, University of Science and Technology, Daejeon (Korea, Republic of)

    2015-01-15

    The electromagnetic proton firehose instability is driven by excessive parallel temperature anisotropy, T{sub ∥} > T{sub ⊥} (or more precisely, parallel pressure anisotropy, P{sub ∥} > P{sub ⊥}) in high-beta plasmas. Together with kinetic instabilities driven by excessive perpendicular temperature anisotropy, namely, electromagnetic proton cyclotron and mirror instabilities, its role in providing the upper limit for the temperature anisotropy in the solar wind is well-known. A recent Letter [Seough et al., Phys. Rev. Lett. 110, 071103 (2013)] employed quasilinear kinetic theory for these instabilities to explain the observed temperature anisotropy upper bound in the solar wind. However, the validity of quasilinear approach has not been rigorously tested until recently. In a recent paper [Seough et al., Phys. Plasmas 21, 062118 (2014)], a comparative study is carried out for the first time in which quasilinear theory of proton cyclotron instability is tested against results obtained from the particle-in-cell simulation method, and it was demonstrated that the agreement was rather excellent. The present paper addresses the same issue involving the proton firehose instability. Unlike the proton cyclotron instability, however, it is found that the quasilinear approximation enjoys only a limited range of validity, especially for the wave dynamics and for the relatively high-beta regime. Possible causes and mechanisms responsible for the discrepancies are speculated and discussed.

  2. Beam diagnostics using an emittance measurement device

    International Nuclear Information System (INIS)

    Sarstedt, M.; Becker, R.; Klein, H.; Maaser, A.; Mueller, J.; Thomae, R.; Weber, M.

    1995-01-01

    For beam diagnostics aside from Faraday cups for current measurements and analysing magnets for the determination of beam composition and energy the most important tool is an emittance measurement device. With such a system the distribution of the beam particles in phase-space can be determined. This yields information not only on the position of the particles but also on their angle with respect to the beam axis. There are different kinds of emittance measurement devices using either circular holes or slits for separation of part of the beam. The second method (slit-slit measurement), though important for the determination of the rms-emittance, has the disadvantage of integrating over the y- and y'-coordinate (measurement in xx'-plane assumed). This leads to different emittance diagrams than point-point measurements, since in xx'-plane for each two corresponding points of rr'-plane there exists a connecting line. With regard to beam aberrations this makes xx'-emittances harder to interpret. In this paper the two kinds of emittance diagrams are discussed. Additionally the influence of the slit height on the xx'-emittance is considered. The analytical results are compared to experimental measurements in rr'-, rx'- and xx'-phase-space. (orig.)

  3. Spectroscopy of light neutron deficient nuclei: 31Ar and 27S decays

    International Nuclear Information System (INIS)

    Borrel, V.

    1991-01-01

    Light neutron-deficient nuclei exhibit several interesting decay modes. In some cases, beta-delayed alpha emission becomes possible, and beta-delayed three-proton emission can be allowed. The energy spectra of the emitted protons should give informations on the position of the isobaric analog state and on its deexcitation modes. Experimental results obtained at GANIL with the LISE spectrometer on the decay of the isotopes 31 Ar and 27 S are presented. These data are discussed and compared with the predicted isobaric analog state excitation energies and with shell-model calculations. (G.P.) 13 refs.; 7 figs.; 1 tab

  4. Study of the irradiation effects on thorium phosphate diphosphate ({beta}-TPD): consequences on its chemical durability; Etude des effets d'irradiation sur le phosphate diphosphate de thorium ({beta}-PDT): consequences sur la durabilite chimique

    Energy Technology Data Exchange (ETDEWEB)

    Tamain, C

    2005-12-15

    Since Thorium Phosphate Diphosphate (beta-TPD) can be considered as a potential host matrix for long-term storage in underground repository, it is necessary to study the irradiation effects on the structure of this ceramics and the consequences on its chemical durability. Sintered samples of beta-TPD and of associated solid solutions of beta-TUPD were irradiated under ion beams and then altered in aqueous solutions. Depending on the electronic LET value, beta-TPD can be completely or partly amorphized. Furthermore, the ability of recrystallization of the amorphous material by thermal annealing was also demonstrated. Some leaching tests, realized on these irradiated samples, have shown a significant effect of the amorphous fraction on the normalized dissolution rate which was increased by a factor of 10 from the crystallized to the fully amorphized material. Correlatively, the amorphous fraction also modified the delay to reach the saturation conditions associated to the thermodynamic equilibria involved. On the other hand, it exhibited no influence neither on other kinetic parameters, such as activation energy of the dissolution process or partial order related to the proton concentration, nor on the nature of the neo-formed phase formed at the saturation of the leachate and identified as Thorium Phosphate Hydrogeno-Phosphate Hydrate (TPHPH). Beta-TUPD samples were also irradiated by gamma and alpha rays during leaching tests to study the effects of radiolysis in the leaching medium on the normalized leaching rate. It appeared that the radiolytic species occurring in the dissolution mechanism were unstable, disappearing quickly when stopping the irradiation. (author)

  5. The Electroluminescence Mechanism of Solution-Processed TADF Emitter 4CzIPN Doped OLEDs Investigated by Transient Measurements

    Directory of Open Access Journals (Sweden)

    Peng Wang

    2016-10-01

    Full Text Available High efficiency, solution-processed, organic light emitting devices (OLEDs, using a thermally-activated delayed fluorescent (TADF emitter, 1,2,3,5-tetrakis(carbazol-9-yl-4,6-dicyanobenzene (4CzIPN, are fabricated, and the transient electroluminescence (EL decay of the device with a structure of [ITO/PEDOT: PSS/4CzIPN 5 wt % doped 4,40-N,N0-dicarbazolylbiphenyl(CBP/bis-4,6-(3,5-di-4-pyridylphenyl-2-methylpyrimidine (B4PyMPM/lithium fluoride (LiF/Al], is systematically studied. The results shed light on the dominant operating mechanism in TADF-based OLEDs. Electroluminescence in the host–guest system is mainly produced from the 4CzIPN emitter, rather than the exciplex host materials.

  6. Beta decay of {sup 97}Ag: evidence for the Gamow-Teller resonance near {sup 100}Sn

    Energy Technology Data Exchange (ETDEWEB)

    Hu Zhiqiang

    1999-03-01

    In two complementary measurements, a cube like array of 6 Euroball-Cluster germanium detectors and a total-absorption {gamma}-spectrometer were used to investigate the {beta} decay of {sup 97}Ag, a three proton-hole nucleus with respect to the {sup 100}Sn core. The half-life and Q{sub EC} value of the decay of the 9/2{sup +} ground-state of {sup 97}Ag were determined to be 25.9(4) s and 6.98(11) MeV respectively. A total of 603 {gamma} rays (578 new) was observed, and 151 levels (132 new) in {sup 97}Pd have been identified. An interesting {beta}-delayed {gamma} cascade was observed, which comprises 6 {gamma}-transitions with a de-excitation pattern involving an initial increase of the level spin. The Gamow-Teller (GT) {beta}-decay strength distributions from the two measurements reveal a large GT resonance around 4 MeV with a width of about 1.8 MeV. The hindrance factor for the total GT strength summed from the ground-state up to 6 MeV excitation energy in {sup 97}Pd, amounts to 4.3(6) with reference to a shell-model prediction. This factor is discussed in comparison with a core-polarization and a Monte-Carlo shell-model calculation. (orig.)

  7. Considerations of beta and electron transport in internal dose calculations. Final progress report, 1994 -1998

    International Nuclear Information System (INIS)

    Bolch, W.E.

    1998-01-01

    This research focused on the following major tasks: improved dosimetric models of the head and brain; development of improved skeletal dosimetry models; development of dosimetric techniques for nonuniform activity distributions; pediatric dosimetry phantoms and radionuclide S values; microdosimetry of beta emitters in radioimmunotherapy; and mechanisms of molecular radiation damage

  8. Nonintercepting emittance monitor

    International Nuclear Information System (INIS)

    Miller, R.H.; Clendenin, J.E.; James, M.B.; Sheppard, J.C.

    1983-08-01

    A nonintercepting emittance monitor is a helpful device for measuring and improving particle beams in accelerators and storage rings as it allows continuous monitoring of the beam's distribution in phase space, and perhaps closed loop computer control of the distributions. Stripline position monitors are being investigated for use as nonintercepting emittance monitors for a beam focused by a FODO array in the first 100 meters of our linear accelerator. The technique described here uses the signal from the four stripline probes of a single position monitor to measure the quadrupole mode of the wall current in the beam pipe. This current is a function of the quadrupole moment of the beam, sigma 2 /sub x/ - sigma 2 /sub y/. In general, six independent measurements of the quadrupole moment are necessary to determine the beam emittance. This technique is dependent on the characteristically large variations of sigma 2 /sub x/ - sigma 2 /sub y/ in a FODO array. It will not work in a focusing system where the beam is round at each focusing element

  9. Study of once and twice forbidden {beta} transitions; Contribution a l'etude de transitions {beta} une fois et deux fois interdites

    Energy Technology Data Exchange (ETDEWEB)

    Hocquenghem, J C [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1967-09-01

    The realisation of an experimental set up for directional angular correlation measurements allowed us to determine {beta} - {gamma} angular correlations. These measurements together with the determination of the {beta} shape-factor have been made for the following transitions: the first forbidden {beta}{sup -} transitions of 386 keV in the {sup 177}Lu disintegration and of 352 keV in the {sup 175}Yb disintegration. The experimental results have been compared with theoretical predictions of the Nilsson's model; the twice forbidden {beta}{sup -} transition of 473 keV in the {sup 94}Nb disintegration. The {beta} transition nuclear matrix elements have been extracted from the experimental results. Comparison have been made with the theoretical values calculated by taking for nuclear wavefunctions those obtained by diagonalization of the residual interaction and assuming that protons and neutrons outside the {sup 90}Zr core are respectively on the 1 g 9/2 and 2 d 5/2 orbits. (author) [French] La realisation d'un ensemble de mesures de correlations angulaires directionnelles nous a permis la mesure de correlations {beta} - {gamma} en fonction de l'energie. En completant celles-ci par la mesure du facteur de forme du spectre {beta}, nous avons pu etudier ainsi: d'une part, les transitions {beta}{sup -} une fois interdites de 386 keV de la desintegration de {sup 177}Lu et de 352 keV de la desintegration de {sup 175}Yb, Les resultats experimentaux ont ete compares aux valeurs calculees dans le modele de Nilsson; d'autre part, la transition {beta}- deux fois interdite de 473 keV de la desintegration de {sup 94}Nb. Les elements de matrice nucleaire de la transition {beta}, extraits des resultats experimentaux, ont ete compares aux valeurs theoriques calculees. Les fonctions d'ondes nucleaires utilisees ont ete obtenues par diagonalisation de l'interaction residuelle en supposant que les protons et les neutrons, en dehors du coeur forme par le {sup 90}Zr, sont respectivement

  10. Emittance measurements by variable quadrupole method

    International Nuclear Information System (INIS)

    Toprek, D.

    2005-01-01

    The beam emittance is a measure of both the beam size and beam divergence, we cannot directly measure its value. If the beam size is measured at different locations or under different focusing conditions such that different parts of the phase space ellipse will be probed by the beam size monitor, the beam emittance can be determined. An emittance measurement can be performed by different methods. Here we will consider the varying quadrupole setting method.

  11. Simultaneous Two-Proton Emission Process of Neutron Deficient Nuclei

    International Nuclear Information System (INIS)

    Rodrigues, M. M. N.; Duarte, S. B.; Leite, T. N.; Teruya, N.

    2011-01-01

    In a previous work, we have calculated the one-proton emission rate of nuclei near the proton drip line, by using an analytical barrier parametrization. The calculation is based on the WKB-approximation and half-lives are obtained in good agreement with the existing experimental data for one-proton emitters. Motivated by these results, in present work, we have eliminated the artificial barrier parametrization previously used, constructing a realistic barrier composed by the superposition of a nuclear Wood-Saxon potential form plus the coulomb and centrifugal barrier. The purpose here is to see if the simple WKB-calculation is still able to reproduce recent observed experimental results for two-proton emission from 45 Fe. This decay mode has been observed by Miernik et al., reporting the proton energy distribution and half-life energy dependence for 45 Fe simultaneous 2p-emission. For theoretical determination of the half-life and these energy distributions we evoked a statistical assumption of a pioneering Goldansky's work for discussing simultaneous two-proton emission. We have shown that our calculation reproduce in quite good agreement the energy distribution and is also able to offer good half-life result with an appropriated composition of involved values of the angular momentum decay.

  12. DoPET: an in-treatment monitoring system for proton therapy at 62 MeV

    Science.gov (United States)

    Rosso, V.; Belcari, N.; Bisogni, M. G.; Camarlinghi, N.; Cirrone, G. A. P.; Collini, F.; Cuttone, G.; Del Guerra, A.; Milluzzo, G.; Morrocchi, M.; Raffaele, L.; Romano, F.; Sportelli, G.; Zaccaro, E.

    2016-12-01

    Proton beam radiotherapy is highly effective in treating cancer thanks to its conformal dose deposition. This superior capability in dose deposition has led to a massive growth of the treated patients around the world, raising the need of treatment monitoring systems. An in-treatment PET system, DoPET, was constructed and tested at CATANA beam-line, LNS-INFN in Catania, where 62 MeV protons are used to treat ocular melanoma. The PET technique profits from the beta+ emitters generated by the proton beam in the irradiated body, mainly 15-O and 11-C. The current DoPET prototype consists of two planar 15 cm × 15 cm LYSO-based detector heads. With respect to the previous versions, the system was enlarged and the DAQ up-graded during the years so now also anthropomorphic phantoms, can be fitted within the field of view of the system. To demonstrate the capability of DoPET to detect changes in the delivered treatment plan with respect to the planned one, various treatment plans were used delivering a standard 15 Gy fraction to an anthropomorphic phantom. Data were acquired during and after the treatment delivery up to 10 minutes. When the in-treatment phase was long enough (more than 1 minute), the corresponding activated volume was visible just after the treatment delivery, even if in presence of a noisy background. The after-treatment data, acquired for about 9 minutes, were segmented finding that few minutes are enough to be able to detect changes. These experiments will be presented together with the studies performed with PMMA phantoms where the DoPET response was characterized in terms of different dose rates and in presence of range shifters: the system response is linear up to 16.9 Gy/min and has the ability to see a 1 millimeter range shifter.

  13. DoPET: an in-treatment monitoring system for proton therapy at 62 MeV

    International Nuclear Information System (INIS)

    Rosso, V.; Belcari, N.; Bisogni, M.G.; Camarlinghi, N.; Guerra, A. Del; Morrocchi, M.; Sportelli, G.; Zaccaro, E.; Cirrone, G.A.P.; Cuttone, G.; Milluzzo, G.; Raffaele, L.; Romano, F.; Collini, F.

    2016-01-01

    Proton beam radiotherapy is highly effective in treating cancer thanks to its conformal dose deposition. This superior capability in dose deposition has led to a massive growth of the treated patients around the world, raising the need of treatment monitoring systems. An in-treatment PET system, DoPET, was constructed and tested at CATANA beam-line, LNS-INFN in Catania, where 62 MeV protons are used to treat ocular melanoma. The PET technique profits from the beta+ emitters generated by the proton beam in the irradiated body, mainly 15-O and 11-C. The current DoPET prototype consists of two planar 15 cm × 15 cm LYSO-based detector heads. With respect to the previous versions, the system was enlarged and the DAQ up-graded during the years so now also anthropomorphic phantoms, can be fitted within the field of view of the system. To demonstrate the capability of DoPET to detect changes in the delivered treatment plan with respect to the planned one, various treatment plans were used delivering a standard 15 Gy fraction to an anthropomorphic phantom. Data were acquired during and after the treatment delivery up to 10 minutes. When the in-treatment phase was long enough (more than 1 minute), the corresponding activated volume was visible just after the treatment delivery, even if in presence of a noisy background. The after-treatment data, acquired for about 9 minutes, were segmented finding that few minutes are enough to be able to detect changes. These experiments will be presented together with the studies performed with PMMA phantoms where the DoPET response was characterized in terms of different dose rates and in presence of range shifters: the system response is linear up to 16.9 Gy/min and has the ability to see a 1 millimeter range shifter.

  14. Multinozzle emitter arrays for ultrahigh-throughput nanoelectrospray mass spectrometry

    Science.gov (United States)

    Wang, Daojing; Mao, Pan; Wang, Hung-Ta; Yang, Peidong

    2017-10-17

    The present invention provides for a structure comprising a plurality of emitters, wherein a first nozzle of a first emitter and a second nozzle of a second emitter emit in two directions that are not or essentially not in the same direction; wherein the walls of the nozzles and the emitters form a monolithic whole. The present invention also provides for a structure comprising an emitter with a sharpened end from which the emitter emits; wherein the emitters forms a monolithic whole. The present invention also provides for a fully integrated separation of proteins and small molecules on a silicon chip before the electrospray mass spectrometry analysis.

  15. Design and device construction for plane tables preparation for counter alpha/beta total; Diseno y construccion de dispositivo para preparacion de planchetas para contador alfa/beta total

    Energy Technology Data Exchange (ETDEWEB)

    Galicia C, F. J.; Monroy G, F., E-mail: fgalicia82@yahoo.com [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2014-10-15

    This work presents the design and assembly of a device for plane tables preparation for quantification alpha/beta total of radioactive waste samples. The determination of the activity index alpha/beta total is used to detect a wide variety of matrices quickly and the concentration of alpha and/or beta emitters of the contained radionuclides in different samples. In particular, the determination of the activity index alpha and beta total of radioactive wastes involves the digestion of samples in aggressive means that will be evaporated to dryness for its quantification. With the purpose of controlling the emission of corrosive gases during the preparation of the plane tables for the quantification of the index alpha and beta total, was designed and built the device in the Radioactive Waste Laboratory that allows to prepare plane tables for proportional counters in a sure and efficient way. The device is constituted by heating equipment, evaporation cylinder and a gases cleaning system. The self-absorption curve got ready starting from the device. (Author)

  16. Hybrid emitter all back contact solar cell

    Science.gov (United States)

    Loscutoff, Paul; Rim, Seung

    2016-04-12

    An all back contact solar cell has a hybrid emitter design. The solar cell has a thin dielectric layer formed on a backside surface of a single crystalline silicon substrate. One emitter of the solar cell is made of doped polycrystalline silicon that is formed on the thin dielectric layer. The other emitter of the solar cell is formed in the single crystalline silicon substrate and is made of doped single crystalline silicon. The solar cell includes contact holes that allow metal contacts to connect to corresponding emitters.

  17. The acute effects of alpha and beta irradiation of mouse skin and the factors affecting the response

    International Nuclear Information System (INIS)

    Needham, S.G.; Coggle, J.E.

    1991-01-01

    Several problems regarding acute effects of alpha and beta irradiation were investigated in order to clarify protection problems of localised doses to the skin. A study into the acute biological effects of different energy beta emitters and the effects of energy and area on the response showed direct relationships between these criteria for a range of different acute responses with different time courses. Three different types of acute response were found and these are described as 'moist desquamation', 'acute ulceration' and 'acute epidermal necrosis'. An unexpected finding was that the lower energy beta emitter 170 Tm was as efficient at inducing scab formation as the higher energy 90 Sr sources for the same area of exposure. Experiments using 2x4 cm 2 exposures to 224 Cm alpha particles showed that the response to this poorly penetrating radiation was minimal after doses as high as 180 Gy measured at 10 μm into the skin. In comparison, large area exposure to 170 Tm produced areas of prolonged scabbing after doses up to 100 Gy. However, the intensity of the reaction varied between strains. (author)

  18. Emittance measurements of the CLIO electron beam

    Science.gov (United States)

    Chaput, R.; Devanz, G.; Joly, P.; Kergosien, B.; Lesrel, J.

    1997-02-01

    We have designed a setup to measure the transverse emittance at the CLIO accelerator exit, based on the "3 gradients" method. The beam transverse size is measured simply by scanning it with a steering coil across a fixed jaw and recording the transmitted current, at various quadrupole strengths. A code then performs a complete calculation of the emittance using the transfer matrix of the quadrupole instead of the usual classical lens approximation. We have studied the influence of various parameters on the emittance: Magnetic field on the e-gun and the peak current. We have also improved a little the emittance by replacing a mismatched pipe between the buncher and accelerating section to avoid wake-field effects; The resulting improvements of the emittance have led to an increase in the FEL emitted power.

  19. Comparison of initial and delayed myocardial imaging with beta-methyl-p-[[sup 123]I]-iodophenylpentadecanoic acid in acute myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Naruse, Hitoshi; Yoshimura, Noriko; Yamamoto, Juro; Morita, Masato; Fukutake, Naoshige; Ohyanagi, Mitsumasa; Iwasaki, Tadaaki; Fukuchi, Minoru (Hyogo Coll. of Medicine, Nishinomiya (Japan))

    Myocardial imaging using [beta]-methyl-p-[[sup 123]I]-iodophenylpentadecanoic acid (BMIPP) of 15 patients with acute myocardial infarction was performed to assess 'fill-in' and 'washout' defects in the delayed myocardial image. The initial and delayed images were evaluated by a visual and quantitative washout rate method. Visual judgement found 8/180 (4%) segments showed 'fill-in' defects, and 24/180 segments (13%) showed 'washout' defects. There was no relationship between days from onset to the study and the frequency of fill-in and washout defects. The mean washout rate in the segments with 'fill-in' defects was 9.0[+-]16.6%, and that of 'washout' defects was 24.9[+-]18.1% which was significantly higher than in controls (8.7[+-]15.4%, p<0.05). There was no correlation between mean washout rate and total blood lipids, total cholesterol, triglyceride and HDL-cholesterol. Therefore, neither time from onset nor blood lipids level was related to changes from the initial image to the delayed image. These changes may be due to relative (false) findings due to changes in circumference, and may be based on myocardial characteristics after myocardial infarction and/or reperfusion. (author).

  20. Mechanisms of proton relay and product release by Class A β-lactamase at ultrahigh resolution

    Energy Technology Data Exchange (ETDEWEB)

    Lewandowski, Eric M. [Department of Molecular Medicine, University of South Florida College of Medicine, Tampa FL USA; Lethbridge, Kathryn G. [Department of Molecular Medicine, University of South Florida College of Medicine, Tampa FL USA; Sanishvili, Ruslan [GMCA@APS, X-ray Science Division, Advanced Photon Source, Argonne National Laboratory, IL USA; Skiba, Joanna [Department of Organic Chemistry, Faculty of Chemistry, University of Lodz, Poland; Kowalski, Konrad [Department of Organic Chemistry, Faculty of Chemistry, University of Lodz, Poland; Chen, Yu [Department of Molecular Medicine, University of South Florida College of Medicine, Tampa FL USA

    2017-11-20

    The beta-lactam antibiotics inhibit penicillin-binding proteins (PBPs) by forming a stable, covalent, acyl-enzyme complex. During the evolution from PBPs to Class A beta-lactamases, the beta-lactamases acquired Glu166 to activate a catalytic water and cleave the acyl-enzyme bond. Here we present three product complex crystal structures of CTX-M-14 Class A beta-lactamase with a ruthenocene-conjugated penicillin-a 0.85 angstrom resolution structure of E166A mutant complexed with the penilloate product, a 1.30 angstrom resolution complex structure of the same mutant with the penicilloate product, and a 1.18 angstrom resolution complex structure of S70G mutant with a penicilloate product epimer-shedding light on the catalytic mechanisms and product inhibition of PBPs and Class A beta-lactamases. The E166A-penilloate complex captured the hydrogen bonding network following the protonation of the leaving group and, for the first time, unambiguously show that the ring nitrogen donates a proton to Ser130, which in turn donates a proton to Lys73. These observations indicate that in the absence of Glu166, the equivalent lysine would be neutral in PBPs and therefore capable of serving as the general base to activate the catalytic serine. Together with previous results, this structure suggests a common proton relay network shared by Class A beta-lactamases and PBPs, from the catalytic serine to the lysine, and ultimately to the ring nitrogen. Additionally, the E166A-penicilloate complex reveals previously unseen conformational changes of key catalytic residues during the release of the product, and is the first structure to capture the hydrolyzed product in the presence of an unmutated catalytic serine.

  1. Delayed luminescence in a multiparameter approach to evaluation and reduction of radiobiological risks

    Science.gov (United States)

    Grasso, Rosaria; Cammarata, Francesco Paolo; Minafra, Luigi; Marchese, Valentina; Russo, Giorgio; Manti, Lorenzo; Musumeci, Francesco; Scordino, Agata

    2017-07-01

    In the framework of the research project ETHICS "Pre-clinical experimental and theoretical studies to improve treatment and protection by charged particles" funded by the National Nuclear Physics Institute, Italy, we studied the phenomenon called delayed luminescence emitted by non-tumorigenic breast epithelial MCF10A cell line after proton irradiation at different doses (0.5, 2, 6, 9 Gy). The aim is to found possible correlations between delayed luminescence and in vitro damaging induced by ion irradiation. The first results of this research show that the delayed luminescence kinetics is proton dose dependent. An interesting correlation between delayed luminescence and clonogenic potential was observed.

  2. 2-D emittance equation with acceleration and compression

    International Nuclear Information System (INIS)

    Hahn, K.D.; Smith, L.

    1988-10-01

    Since both acceleration and compression are required for an Inertial Fusion Driver, the understanding of their effect on the beam quality, emittance, is important. This report attempts to generalize the usual emittance formula for the drifting beam to include these effects. The derivation of the 2-D emittance equation is carried out and a comparison with the particle code results is given. The 2-D emittance at a given axial location is reasonable to consider for a long beam, particularly with velocity tilt; transverse emittance averaged over the entire bunch is not a useful quantity. 6 refs., 2 figs., 1 tab

  3. The rates and time-delay distribution of multiply imaged supernovae behind lensing clusters

    Science.gov (United States)

    Li, Xue; Hjorth, Jens; Richard, Johan

    2012-11-01

    Time delays of gravitationally lensed sources can be used to constrain the mass model of a deflector and determine cosmological parameters. We here present an analysis of the time-delay distribution of multiply imaged sources behind 17 strong lensing galaxy clusters with well-calibrated mass models. We find that for time delays less than 1000 days, at z = 3.0, their logarithmic probability distribution functions are well represented by P(log Δt) = 5.3 × 10-4Δttilde beta/M2502tilde beta, with tilde beta = 0.77, where M250 is the projected cluster mass inside 250 kpc (in 1014M⊙), and tilde beta is the power-law slope of the distribution. The resultant probability distribution function enables us to estimate the time-delay distribution in a lensing cluster of known mass. For a cluster with M250 = 2 × 1014M⊙, the fraction of time delays less than 1000 days is approximately 3%. Taking Abell 1689 as an example, its dark halo and brightest galaxies, with central velocity dispersions σ>=500kms-1, mainly produce large time delays, while galaxy-scale mass clumps are responsible for generating smaller time delays. We estimate the probability of observing multiple images of a supernova in the known images of Abell 1689. A two-component model of estimating the supernova rate is applied in this work. For a magnitude threshold of mAB = 26.5, the yearly rate of Type Ia (core-collapse) supernovae with time delays less than 1000 days is 0.004±0.002 (0.029±0.001). If the magnitude threshold is lowered to mAB ~ 27.0, the rate of core-collapse supernovae suitable for time delay observation is 0.044±0.015 per year.

  4. Emittance growth in rf linacs

    International Nuclear Information System (INIS)

    Jameson, R.A.

    1979-01-01

    As the space-charge limit is approached, the current that can be accelerated in an rf linac and the output emittance that can be expected are discussed. The role of the envelope equations to estimate limits is outlined. The results of numerical experiments to explore general properties of emittance growth are given

  5. Study of 2 proton radioactivity of 54Zn with a time projection chamber

    International Nuclear Information System (INIS)

    Ascher, P.

    2011-11-01

    The study of nuclei at the proton drip-line is a recent and efficient tool to prove the nuclear structure far from stability. In particular, the two-proton radioactivity phenomenon predicted in 1960 has been discovered in 2002. This work concerns an experiment performed at GANIL, in order to study the two-proton radioactivity of 54 Zn with a time projection chamber, developed for the individual detection of each proton and the reconstruction of their tracks in three dimensions. The data analysis allowed to determine the correlations in energy and angle between the two protons. They have been compared to a theoretical model, which takes into account the dynamics of the emission, giving information about the structure of the emitter. However, due to the very low statistics, the interpretation of the results is limited but these results open very interesting prospects for further studies of nuclei at the limits of the existence. (author)

  6. Observation of Octupole Driven Resonance Phenomena with Space Charge at the CERN Proton Synchrotron

    CERN Document Server

    Métral, E; Martini, M; Steerenberg, R; Franchetti, Giuliano; Hofmann, I

    2006-01-01

    Several benchmarking space charge experiments have been performed during the last few years in the CERN Proton Synchrotron. These controlled experiments are of paramount importance to validate the present very powerful simulation codes. The observations of the combined effect of space charge and nonlinear resonance on beam loss and emittance, using a single controllable octupole during ~ 1 s at 1.4 GeV kinetic energy, are discussed in some detail in the present paper. By lowering the working point towards the octupolar resonance, a gradual transition from a regime of loss-free core emittance blow-up to a regime of continuous loss was found.

  7. Development of a high current H- injector for the proton storage ring at LAMPF

    International Nuclear Information System (INIS)

    York, R.L.; Stevens, R.R.; DeHaven, R.A.; McConnell, J.R.; Chamberlin, E.P.; Kandarian, R.

    1984-01-01

    A new high-current H - injector has been installed at LAMPF for the Proton Storage Ring. The injector is equipped with a multicusp surface-production H - ion source that was developed at LAMPF. The ion source is capable of long-term operation at 20 mA of H - current at 10% duty factor and with normalized beam emittance of 0.08 cm-mrad (95% beam fraction). Details of the development program, the injector design, and initial operating experience are discussed. Included in the discussion is a comparison of intensity and emittance measurements of the same H - beam at 100 keV and 750 keV. 4 references, 6 figures

  8. Practical Radiobiology for Proton Therapy Planning

    Science.gov (United States)

    Jones, Bleddyn

    2017-12-01

    Practical Radiobiology for Proton Therapy Planning covers the principles, advantages and potential pitfalls that occur in proton therapy, especially its radiobiological modelling applications. This book is intended to educate, inform and to stimulate further research questions. Additionally, it will help proton therapy centres when designing new treatments or when unintended errors or delays occur. The clear descriptions of useful equations for high LET particle beam applications, worked examples of many important clinical situations, and discussion of how proton therapy may be optimized are all important features of the text. This important book blends the relevant physics, biology and medical aspects of this multidisciplinary subject. Part of Series in Physics and Engineering in Medicine and Biology.

  9. Preliminary design of a dedicated proton therapy linac

    International Nuclear Information System (INIS)

    Hamm, R.W.; Crandall, K.R.; Potter, J.M.

    1991-01-01

    The preliminary design has been completed for a low current, compact proton linac dedicated to cancer therapy. A 3 GHz side-coupled structure accelerates the beam from a 70 MeV drift tube linac using commercially available S-band rf power systems and accelerating cavities. This significantly reduces the linac cost and allows incremental energies up to 250 MeV. The short beam pulse width and high repetition rate make the linac similar to the high energy electron linacs now used for cancer therapy, yet produce a proton flux sufficient for treatment of large tumors. The high pulse repetition rate permits raster scanning, and the small output beam size and emittance result in a compact isocentric gantry design. Such a linac will reduce the facility and operating costs for a dedicated cancer therapy system

  10. Minimum emittance in TBA and MBA lattices

    Science.gov (United States)

    Xu, Gang; Peng, Yue-Mei

    2015-03-01

    For reaching a small emittance in a modern light source, triple bend achromats (TBA), theoretical minimum emittance (TME) and even multiple bend achromats (MBA) have been considered. This paper derived the necessary condition for achieving minimum emittance in TBA and MBA theoretically, where the bending angle of inner dipoles has a factor of 31/3 bigger than that of the outer dipoles. Here, we also calculated the conditions attaining the minimum emittance of TBA related to phase advance in some special cases with a pure mathematics method. These results may give some directions on lattice design.

  11. Minimum emittance in TBA and MBA lattices

    International Nuclear Information System (INIS)

    Xu Gang; Peng Yuemei

    2015-01-01

    For reaching a small emittance in a modern light source, triple bend achromats (TBA), theoretical minimum emittance (TME) and even multiple bend achromats (MBA) have been considered. This paper derived the necessary condition for achieving minimum emittance in TBA and MBA theoretically, where the bending angle of inner dipoles has a factor of 3 1/3 bigger than that of the outer dipoles. Here, we also calculated the conditions attaining the minimum emittance of TBA related to phase advance in some special cases with a pure mathematics method. These results may give some directions on lattice design. (authors)

  12. Cancer from internal emitters

    International Nuclear Information System (INIS)

    Boecker, B.B.; Griffith, W.C. Jr.

    1995-01-01

    Irradiation from internal emitters, or internally deposited radionuclides, is an important component of radiation exposures encountered in the workplace, home, or general environment. Long-term studies of human populations exposed to various internal emitters by different routes of exposure are producing critical information for the protection of workers and members of the general public. The purpose of this report is to examine recent developments and discuss their potential importance for understanding lifetime cancer risks from internal emitters. The major populations of persons being studied for lifetime health effects from internally deposited radionuclides are well known: Lung cancer in underground miners who inhaled Rn progeny, liver cancer from persons injected with the Th-containing radiographic contrast medium Thorotrast, bone cancer from occupational or medical intakes of 226 Ra or medical injections of 224 Ra, and thyroid cancer from exposures to iodine radionuclides in the environment or for medical purposes

  13. Method validation for simultaneous counting of Total α , β in Drinking Water using Liquid Scintillation Counter

    International Nuclear Information System (INIS)

    Al-Masri, M. S.; Nashawati, A.

    2014-05-01

    In this work, Method Validation Methods and Pulse Shape Analysis were validated to determine gross Alpha and Beta Emitters in Drinking Water using Liquid Scintillation Counter Win spectral 1414. Validation parameters include Method Detection Limit, Method Quantitation Limit, Repeatability Limit, Intermediate Precision, Trueness) Bias), Recovery Coefficient, Linearity and Uncertainty Budget in analysis. The results show that the Method Detection Limit and Method Quantitation Limit were 0.07, 0.24 Bq/l for Alpha emitters respectively, and 0.42, 1.4 Bq/l for Beta emitters, respectively. The relative standard deviation of Repeatability Limit reached 2.81% for Alpha emitters and 3.96% for Beta emitters. In addition to, the relative standard deviation of Intermediate Precisionis was 0.54% for Alpha emitters and 1.17% for Beta emitters. Moreover, the trueness was - 7.7% for Alpha emitters and - 4.5% for Beta emitters. Recovery Coefficient ranged between 87 - 96% and 88-101 for Alpha and Beta emitters, respectively. Linearity reached 1 for both Alpha and Beta emitters. on the other hand, Uncertainty Budget for all continents was 96.65% ,83.14% for Alpha and Beta emitters, respectively (author).

  14. High Intensity Beam Issues in the CERN Proton Synchrotron

    CERN Document Server

    Aumon, Sandra; Rivkin, Leonid

    This PhD work is about limitations of high intensity proton beams observed in the CERN Proton Synchrotron (PS) and, in particular, about issues at injection and transition energies. With its 53 years, the CERN PS would have to operate beyond the limit of its performance to match the future requirements. Beam instabilities driven by transverse impedance and aperture restrictions are important issues for the operation and for the High-Luminosity LHC upgrade which foresees an intensity increase delivered by the injectors. The main subject of the thesis concerns the study of a fast transverse instability occurring at transition energy. The proton beams crossing this energy range are particularly sensitive to wake forces because of the slow synchrotron motion. This instability can cause a strong vertical emittance blow-up and severe losses in less than a synchrotron period. Experimental observations show that the particles at the peak density of the beam longitudinal distribution oscillate in the vertical plane du...

  15. Development of Emittance Analysis Software for Ion Beam Characterization

    International Nuclear Information System (INIS)

    Padilla, M.J.; Liu, Yuan

    2007-01-01

    Transverse beam emittance is a crucial property of charged particle beams that describes their angular and spatial spread. It is a figure of merit frequently used to determine the quality of ion beams, the compatibility of an ion beam with a given beam transport system, and the ability to suppress neighboring isotopes at on-line mass separator facilities. Generally, a high-quality beam is characterized by a small emittance. In order to determine and improve the quality of ion beams used at the Holifield Radioactive Ion Beam Facility (HRIBF) for nuclear physics and nuclear astrophysics research, the emittances of the ion beams are measured at the off-line Ion Source Test Facilities. In this project, emittance analysis software was developed to perform various data processing tasks for noise reduction, to evaluate root-mean-square emittance, Twiss parameters, and area emittance of different beam fractions. The software also provides 2D and 3D graphical views of the emittance data, beam profiles, emittance contours, and RMS. Noise exclusion is essential for accurate determination of beam emittance values. A Self-Consistent, Unbiased Elliptical Exclusion (SCUBEEx) method is employed. Numerical data analysis techniques such as interpolation and nonlinear fitting are also incorporated into the software. The software will provide a simplified, fast tool for comprehensive emittance analysis. The main functions of the software package have been completed. In preliminary tests with experimental emittance data, the analysis results using the software were shown to be accurate

  16. DEVELOPMENT OF EMITTANCE ANALYSIS SOFTWARE FOR ION BEAM CHARACTERIZATION

    Energy Technology Data Exchange (ETDEWEB)

    Padilla, M. J.; Liu, Y.

    2007-01-01

    Transverse beam emittance is a crucial property of charged particle beams that describes their angular and spatial spread. It is a fi gure of merit frequently used to determine the quality of ion beams, the compatibility of an ion beam with a given beam transport system, and the ability to suppress neighboring isotopes at on-line mass separator facilities. Generally a high quality beam is characterized by a small emittance. In order to determine and improve the quality of ion beams used at the Holifi eld Radioactive Ion beam Facility (HRIBF) for nuclear physics and nuclear astrophysics research, the emittances of the ion beams are measured at the off-line Ion Source Test Facilities. In this project, emittance analysis software was developed to perform various data processing tasks for noise reduction, to evaluate root-mean-square emittance, Twiss parameters, and area emittance of different beam fractions. The software also provides 2D and 3D graphical views of the emittance data, beam profi les, emittance contours, and RMS. Noise exclusion is essential for accurate determination of beam emittance values. A Self-Consistent, Unbiased Elliptical Exclusion (SCUBEEx) method is employed. Numerical data analysis techniques such as interpolation and nonlinear fi tting are also incorporated into the software. The software will provide a simplifi ed, fast tool for comprehensive emittance analysis. The main functions of the software package have been completed. In preliminary tests with experimental emittance data, the analysis results using the software were shown to be accurate.

  17. Status of international benchmark experiment for effective delayed neutron fraction ({beta}eff)

    Energy Technology Data Exchange (ETDEWEB)

    Okajima, S.; Sakurai, T.; Mukaiyama, T. [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1997-03-01

    To improve the prediction accuracy of the {beta}eff, the program of the international benchmark experiment (Beta Effect Reactor Experiment for a New International Collaborative Evaluation: BERNICE) was planned. This program composed of two parts; BERNICE-MASURCA and BERNICE-FCA. The former one was carried out in the fast critical facility MASURCA of CEA, FRANCE between 1993 and 1994. The latter one started in the FCA, JAERI in 1995 and still is going. In these benchmark experiments, various experimental techniques have been applied for in-pile measurements of the {beta}eff. The accuracy of the measurements was better than 3%. (author)

  18. Detailed Analysis of Apoptosis and Delayed Luminescence of Human Leukemia Jurkat T Cells after Proton Irradiation and Treatments with Oxidant Agents and Flavonoids

    Directory of Open Access Journals (Sweden)

    Irina Baran

    2012-01-01

    Full Text Available Following previous work, we investigated in more detail the relationship between apoptosis and delayed luminescence (DL in human leukemia Jurkat T cells under a wide variety of treatments. We used menadione and hydrogen peroxide to induce oxidative stress and two flavonoids, quercetin, and epigallocatechin gallate, applied alone or in combination with menadione or H2O2. 62 MeV proton beams were used to irradiate cells under a uniform dose of 2 or 10 Gy, respectively. We assessed apoptosis, cell cycle distributions, and DL. Menadione, H2O2 and quercetin were potent inducers of apoptosis and DL inhibitors. Quercetin decreased clonogenic survival and the NAD(PH level in a dose-dependent manner. Proton irradiation with 2 Gy but not 10 Gy increased the apoptotic rate. However, both doses induced a substantial G2/M arrest. Quercetin reduced apoptosis and prolonged the G2/M arrest induced by radiation. DL spectroscopy indicated that proton irradiation disrupted the electron flow within Complex I of the mitochondrial respiratory chain, thus explaining the massive necrosis induced by 10 Gy of protons and also suggested an equivalent action of menadione and quercetin at the level of the Fe/S center N2, which may be mediated by their binding to a common site within Complex I, probably the rotenone-binding site.

  19. Feasibility of proton-activated implantable markers for proton range verification using PET

    Science.gov (United States)

    Cho, Jongmin; Ibbott, Geoffrey; Gillin, Michael; Gonzalez-Lepera, Carlos; Titt, Uwe; Paganetti, Harald; Kerr, Matthew; Mawlawi, Osama

    2013-11-01

    Proton beam range verification using positron emission tomography (PET) currently relies on proton activation of tissue, the products of which decay with a short half-life and necessitate an on-site PET scanner. Tissue activation is, however, negligible near the distal dose fall-off region of the proton beam range due to their high interaction energy thresholds. Therefore Monte Carlo simulation is often supplemented for comparison with measurement; however, this also may be associated with systematic and statistical uncertainties. Therefore, we sought to test the feasibility of using long-lived proton-activated external materials that are inserted or infused into the target volume for more accurate proton beam range verification that could be performed at an off-site PET scanner. We irradiated samples of ≥98% 18O-enriched water, natural Cu foils, and >97% 68Zn-enriched foils as candidate materials, along with samples of tissue-equivalent materials including 16O water, heptane (C7H16), and polycarbonate (C16H14O3)n, at four depths (ranging from 100% to 3% of center of modulation (COM) dose) along the distal fall-off of a modulated 160 MeV proton beam. Samples were irradiated either directly or after being embedded in Plastic Water® or balsa wood. We then measured the activity of the samples using PET imaging for 20 or 30 min after various delay times. Measured activities of candidate materials were up to 100 times greater than those of the tissue-equivalent materials at the four distal dose fall-off depths. The differences between candidate materials and tissue-equivalent materials became more apparent after longer delays between irradiation and PET imaging, due to the longer half-lives of the candidate materials. Furthermore, the activation of the candidate materials closely mimicked the distal dose fall-off with offsets of 1 to 2 mm. Also, signals from the foils were clearly visible compared to the background from the activated Plastic Water® and balsa wood

  20. Quantum efficiency and thermal emittance of metal photocathodes

    Directory of Open Access Journals (Sweden)

    David H. Dowell

    2009-07-01

    Full Text Available Modern electron beams have demonstrated the brilliance needed to drive free electron lasers at x-ray wavelengths with major advances occurring since the invention of the photocathode gun and the realization of emittance compensation. These state-of-the-art electron beams are now becoming limited by the intrinsic thermal emittance of the cathode. In both dc and rf photocathode guns details of the cathode emission physics strongly influence the quantum efficiency and the thermal emittance. Therefore improving cathode performance is essential to increasing the brightness of beams. It is especially important to understand the fundamentals of cathode quantum efficiency and thermal emittance. This paper investigates the relationship between the quantum efficiency and the thermal emittance for metal cathodes using the Fermi-Dirac model for the electron distribution. We use a consistent theory to derive the quantum efficiency and thermal emittance, and compare our results to those of others.

  1. Superconducting Radio-Frequency Cavities for Low-Beta Particle Accelerators

    Science.gov (United States)

    Kelly, Michael

    2012-01-01

    High-power proton and ion linac projects based on superconducting accelerating cavities are driving a worldwide effort to develop and build superconducting cavities for beta < 1. Laboratories and institutions building quarter-wave, halfwave and single- or multi-spoke cavities continue to advance the state of the art for this class of cavities, and the common notion that low-beta SRF cavities fill a need in niche applications and have low performance is clearly no longer valid. This article reviews recent developments and results for SC cavity performance for cavities with beta up to approximately 0.5. The considerable ongoing effort on reduced beta elliptical cell cavities is not discussed. An overview of associated subsystems required to operate low-beta cavities, including rf power couplers and fast and slow tuners, is presented.

  2. Beam phase space and emittance

    International Nuclear Information System (INIS)

    Buon, J.

    1990-12-01

    The classical and elementary results for canonical phase space, the Liouville theorem and the beam emittance are reviewed. Then, the importance of phase portraits to obtain a geometrical description of motion is emphasized, with examples in accelerator physics. Finally, a statistical point of view is used to define beam emittance, to study its law of approximate conservation and to treat two particular examples

  3. SU-C-204-01: A Fast Analytical Approach for Prompt Gamma and PET Predictions in a TPS for Proton Range Verification

    International Nuclear Information System (INIS)

    Kroniger, K; Herzog, M; Landry, G; Dedes, G; Parodi, K; Traneus, E

    2015-01-01

    Purpose: We describe and demonstrate a fast analytical tool for prompt-gamma emission prediction based on filter functions applied on the depth dose profile. We present the implementation in a treatment planning system (TPS) of the same algorithm for positron emitter distributions. Methods: The prediction of the desired observable is based on the convolution of filter functions with the depth dose profile. For both prompt-gammas and positron emitters, the results of Monte Carlo simulations (MC) are compared with those of the analytical tool. For prompt-gamma emission from inelastic proton-induced reactions, homogeneous and inhomogeneous phantoms alongside with patient data are used as irradiation targets of mono-energetic proton pencil beams. The accuracy of the tool is assessed in terms of the shape of the analytically calculated depth profiles and their absolute yields, compared to MC. For the positron emitters, the method is implemented in a research RayStation TPS and compared to MC predictions. Digital phantoms and patient data are used and positron emitter spatial density distributions are analyzed. Results: Calculated prompt-gamma profiles agree with MC within 3 % in terms of absolute yield and reproduce the correct shape. Based on an arbitrary reference material and by means of 6 filter functions (one per chemical element), profiles in any other material composed of those elements can be predicted. The TPS implemented algorithm is accurate enough to enable, via the analytically calculated positron emitters profiles, detection of range differences between the TPS and MC with errors of the order of 1–2 mm. Conclusion: The proposed analytical method predicts prompt-gamma and positron emitter profiles which generally agree with the distributions obtained by a full MC. The implementation of the tool in a TPS shows that reliable profiles can be obtained directly from the dose calculated by the TPS, without the need of full MC simulation

  4. Generalized superradiant assembly for nanophotonic thermal emitters

    Science.gov (United States)

    Mallawaarachchi, Sudaraka; Gunapala, Sarath D.; Stockman, Mark I.; Premaratne, Malin

    2018-03-01

    Superradiance explains the collective enhancement of emission, observed when nanophotonic emitters are arranged within subwavelength proximity and perfect symmetry. Thermal superradiant emitter assemblies with variable photon far-field coupling rates are known to be capable of outperforming their conventional, nonsuperradiant counterparts. However, due to the inability to account for assemblies comprising emitters with various materials and dimensional configurations, existing thermal superradiant models are inadequate and incongruent. In this paper, a generalized thermal superradiant assembly for nanophotonic emitters is developed from first principles. Spectral analysis shows that not only does the proposed model outperform existing models in power delivery, but also portrays unforeseen and startling characteristics during emission. These electromagnetically induced transparency like (EIT-like) and superscattering-like characteristics are reported here for a superradiant assembly, and the effects escalate as the emitters become increasingly disparate. The fact that the EIT-like characteristics are in close agreement with a recent experimental observation involving the superradiant decay of qubits strongly bolsters the validity of the proposed model.

  5. Internal emitter research and standard setting

    International Nuclear Information System (INIS)

    Stannard, J.N.

    1981-01-01

    The history of the use of data from internal emitter research in the derivation of safety standards is reviewed. At first, observed biological effects were correlated with body burdens or exposure levels. This direct approach is illustrated by detailed accounts of the cases of uranium and plutonium. In the 1950's, when it was decided to provide standards for over 200 isotopes, the direct approach was replaced by a system of calculations. This necessitated changes in internal emitter research programs to provide metabolic data, and the development of models such as Reference Man and the Lung and Gastrointestinal Tract models. The continuing contribution of internal emitter research to standard setting can be seen in the references quoted in the metabolic data section of the new ICRP report (ICRP Publication 30). Present trends suggest a possible return to the direct use of internal emitter effects data for obtaining risk estimates. (U.K.)

  6. Is it possible to verify directly a proton-treatment plan using positron emission tomography?

    International Nuclear Information System (INIS)

    Vynckier, S.; Derreumaux, S.; Richard, F.; Wambersie, A.; Bol, A.; Michel, C.

    1993-01-01

    A PET camera is used to visualize the positron activity induced during protonbeam therapy in order to verify directly the proton-treatment plans. The positron emitters created are predominantly the 15 O and 11 C, whose total activity amounts to 12 MBq after an irradiation with 85 MeV protons, delivering 3 Gy in a volume of approximately 300 cm 3 . Although this method is a useful verification of patient setup, care must be taken when deriving dose distributions from activity distributions. Correlation between both quantities is difficult, moreover at the last millimeters of their range, protons will no longer activate tissue. Due to the short half-lives the PET camera must be located close to the treatment facility. (author) 17 refs

  7. Kinematic shifts of β-delayed particles as a probe of β-ν angular correlations

    International Nuclear Information System (INIS)

    Clifford, E.T.H.; Azuma, R.E.; Jackson, K.P.; Koslowsky, V.T.; Hardy, J.C.; Schmeing, H.; Faestermann, T.; Schrewe, U.J.; Evans, H.C.; Hagberg, E.; Toronto Univ., Ontario; Queen's Univ., Kingston, Ontario

    1981-01-01

    Beta-delayed particles undergo a kinematic shift in energy due to recoil motion of the daughter nucleus following beta decay. A careful measurement of this energy shift can be used to establish the ratio of vector to axial vector components in beta transitions. Alpha-beta coincidence data for the beta-delayed alpha decay of 20 Na have been obtained. Component ratios for 6 transitions including the super-allowed branch were found. Limits on charge dependent mixing with the analogue state were deduced for 5 states in 20 Nesup(*). For the superallowed branch the axial vector component was found; the polar vector component was deduced and establishes a value for the vector weak coupling constant of Gsub(V) = (1.355 +- 0.036) x 10 -49 erg cm 3 . (orig.)

  8. Analysis of radionuclide mixtures by {alpha}-{gamma} and {beta}-{gamma} coincidences using a simple device; Analyse de melanges de radionucleides par un dispositif simple de coincidences {alpha}-{gamma} et {beta}-{gamma}

    Energy Technology Data Exchange (ETDEWEB)

    Pottier, R; Berger, R [Commissariat a l' Energie Atomique, Centre d' Etudes Nucleaires de Fontenay-aux-Roses, 92 (France)

    1966-06-01

    A procedure is described for the qualitative and quantitative spectrographic analysis of radioactive sources containing two alpha-gamma emitters having the same alpha energy or two beta-gamma emitters having the same gamma energy. The main apparatus is a multichannel pulse-height analyzer including a coincidence circuit. The principle of the method, the synoptic scheme, the electronic device, the type of sources, and the precautions to be taken or the corrections to take into account are reported. The results obtained in solving the three following problems are discussed as examples of applications of the method: analysis of {sup 241}Am in alpha-gamma sources containing {sup 238}Pu; analysis of {sup 237}Np in beta-gamma sources containing {sup 239}Pu; and analysis of {sup 106}Ru-{sup 106}Rh in beta-gamma sources containing {sup 95}Zr-{sup 95}Nb. (authors) [French] Dans ce. rapport, on presente une methode d'analyse spectrographique qualitative et quantitative de sources radioactives contenant deux emetteurs alpha-gamma de meme energie alpha et deux emetteurs beta-gamma de meme energie gamma. L'organe principal est un analyseur d'amplitude a 400 canaux comprenant un circuit de coincidence. On decrit le principe de la methode, le schema synoptique, l'appareillage, le type des sources, les precautions a prendre ou les corrections a faire. On discute les resultats obtenus dans la solution des trois problemes suivants traites a titre d'application de la methode: 1. analyse d'americium 241 en presence de plutonium 238; 2. analyse de neptunium 237 en presence de plutonium 239; 3. analyse de ruthenium 106-rhodium 106 en presence de zirconium 95-niobium 95. (auteurs)

  9. Radiation dosimetry in radiotherapy with internal emitters

    International Nuclear Information System (INIS)

    Stabin, Michael G.

    1997-01-01

    Full text. Radiation dosimetry radionuclides are currently being labeled to various biological agents used in internal emitter radiotherapy. This talk will review the various technologies and types of radiolabel in current use, with focus on the characterization of the radiation dose to the various important tissues of the body. Methods for obtaining data, developing kinetic models, and calculating radiation doses will be reviewed. Monoclonal antibodies are currently being labeled with both alpha and beta emitting radionuclides in attempts to find effective agents against cancer. Several radionuclides are also being used as bone pain palliation agents. These agents must be studied in clinical trials to determine the biokinetics and radiation dosimetry prior to approval for general use. In such studies, it is important to ensure the collection of the appropriate kinds of data and to collect the data at appropriate time intervals. The uptake and retention of activity in all significant source organs and in excreta be measured periodically (with at least 2 data points phase of uptake or clearance). Then, correct dosimetry methods must be applied - the best available methods for characterizing the radionuclide kinetic and for estimating the dosimetry in the various organs of the body especially the marrow, should be used. Attempts are also under way to develop methods for estimating true patient-specific dosimetry. Cellular and animal studies are also. Valuable in evaluating the efficacy of the agents in shrinking or eliminating tumors; some results from such studies will also be discussed. The estimation of radiation doses to patients in therapy with internal emitters involves several complex phases of analysis. Careful attention to detail and the use of the best available methods are essential to the protection of the patient and a successful outcome

  10. The synthesis of (R)- and (S)-[N-methyl-{sup 11}C]{beta}, {beta}-difluoromethamphetamine for the investigation of the binding mechanism of biogenic amines in vivo

    Energy Technology Data Exchange (ETDEWEB)

    Gillings, N.M.; Gee, A.D. [PET Centre, Aarhus University Hospital, Aarhus C (Denmark); Inoue, O. [School of Allied Health Sciences, Osaka University Medical School, Osaka (Japan)

    1999-04-01

    In an attempt to elucidate the contribution of the extent of nitrogen protonation on the in vivo binding of methamphetamine in the brain, the enantiomers of [N-methyl-{sup 11}C]{beta},{beta}-difluoroamphetamine (4) were prepared for use in positron emission tomography (PET) studies. Thus, the enantiomers of {beta},{beta}-difluoroamphetamine were prepared from trans-{beta}-methylstyrene, via bromination, conversion into the azirine, fluorination and resolution as the tartrate salts. (R)- and (S)-{beta},{beta}-difluoroamphetamine (3) were then each labelled with carbon-11 (t{sub 1/2}=20.4 min) by N-methylation of the corresponding homochiral {beta},{beta}-difluoroamphetamine with [{sup 11}C]methyl iodide. The labelled products were each synthesised, purified and formulated in 35 min, starting from [{sup 11}C]carbon dioxide in 15-16% decay-corrected radiochemical yield, with a radiochemical purity of >99% and specific radioactivity of 50-150 GBq {mu}mol{sup -1} at end of synthesis.

  11. Solid-state single-photon emitters

    Science.gov (United States)

    Aharonovich, Igor; Englund, Dirk; Toth, Milos

    2016-10-01

    Single-photon emitters play an important role in many leading quantum technologies. There is still no 'ideal' on-demand single-photon emitter, but a plethora of promising material systems have been developed, and several have transitioned from proof-of-concept to engineering efforts with steadily improving performance. Here, we review recent progress in the race towards true single-photon emitters required for a range of quantum information processing applications. We focus on solid-state systems including quantum dots, defects in solids, two-dimensional hosts and carbon nanotubes, as these are well positioned to benefit from recent breakthroughs in nanofabrication and materials growth techniques. We consider the main challenges and key advantages of each platform, with a focus on scalable on-chip integration and fabrication of identical sources on photonic circuits.

  12. Emittance growth rates for displaced beams

    International Nuclear Information System (INIS)

    Anderson, O.A.

    1993-05-01

    Emittance growth rates have been previously analyzed for nonuniform beams in linear channels and for initially uniform mismatched beams in nonlinear channels. These studies were for centered beams. Additional emittance growth can arise in cases where the beam is initially displaced. The purpose of this study is to obtain growth rates for displaced beams. This work differs from studies involving random displacement of electrodes. Our analysis assumes instead that the focusing system is perfectly aligned but that the beam is initially displaced with respect to the equilibrium axis. If the focusing force is slightly nonlinear, we find a gradual transfer of the potential energy of beam displacement into kinetic energy associated with emittance growth. We present explicit results for the emittance growth distance as a function of the nonlinearity of the channel. These results will have practical importance for designers of accelerators and transport systems when setting realistic tolerances for initial beam alignment. These tolerances will depend on the nonlinearity and the length of the system

  13. Emittance variations in current-amplifying ion induction linacs

    International Nuclear Information System (INIS)

    Fessenden, T.J.

    1991-01-01

    Since 1985 the Heavy Ion Fusion Accelerator Research program at the Lawrence Berkeley Laboratory has been studying current amplification and emittance variations in MBE-4, a four-cesium-beam induction linac. This experiment models much of the accelerator physics of the electrostatically focused section of a fusion driver. Four space-charge dominated Cs + beams, initially about one meter in length at currents of 5-10 mA, are focused by electrostatic quadrupoles and accelerated in parallel from approximately 200 keV up to one MeV by 24 accelerating gaps. Final currents of 20-40 mA per beam are typical. Recent experiments with extremely low emittance beams (var-epsilon n =0.03 mm-mRad) have investigated variations of transverse and longitudinal normalized emittance for drifting and accelerating beams. These very strongly tune-depressed beams (σ 0 =72 degree, σ∼6 degree) are difficult to match to the accelerator so as to avoid emittance growth during acceleration. During transport strong emittance fluctuations are observed in good qualitative agreement with simulations. Warmer beams with less tune depression exhibit little to no emittance growth, show smaller emittance fluctuations, and are much easier to match. A summary of findings from the MBE-4 studies is presented

  14. Emittance variations in current-amplifying ion induction linacs

    International Nuclear Information System (INIS)

    Fessenden, T.J.

    1991-04-01

    Since 1985 the Heavy Ion Fusion Accelerator Research program at the Lawrence Berkeley Laboratory has been studying current amplification and emittance variations in MBE-4, a four-cesium-beam induction linac. This experiment models much of the accelerator physics of the electrostatically focused section of a fusion driver. Four space-charge dominated Cs + beams, initially about one meter in length at currents of 5--10 mA, are focused by electrostatic quadrupoles and accelerated in parallel from approximately 200 keV up to one MeV by 24 accelerating gaps. Final currents of 20--40 mA per beam are typical. Recent experiments with extremely low emittance beams (ε n = 0.03 mm-mRad) have investigated variations of transverse and longitudinal normalized emittance for drifting and accelerating beams. These very strongly tune-depressed beams (σ o = 72 degrees, σ∼6 degree) are difficult to match the accelerator so as to avoid emittance growth during acceleration. During transport strong emittance fluctuations are observed in good qualitative agreement with simulations. Warmer beams with less tune depression exhibit little to no emittance growth, show smaller emittance fluctuations, and are much easier to match. A summary of findings from the MBE-4 studies is presented. 12 refs., 8 figs

  15. Design and device construction for plane tables preparation for counter alpha/beta total

    International Nuclear Information System (INIS)

    Galicia C, F. J.; Monroy G, F.

    2014-10-01

    This work presents the design and assembly of a device for plane tables preparation for quantification alpha/beta total of radioactive waste samples. The determination of the activity index alpha/beta total is used to detect a wide variety of matrices quickly and the concentration of alpha and/or beta emitters of the contained radionuclides in different samples. In particular, the determination of the activity index alpha and beta total of radioactive wastes involves the digestion of samples in aggressive means that will be evaporated to dryness for its quantification. With the purpose of controlling the emission of corrosive gases during the preparation of the plane tables for the quantification of the index alpha and beta total, was designed and built the device in the Radioactive Waste Laboratory that allows to prepare plane tables for proportional counters in a sure and efficient way. The device is constituted by heating equipment, evaporation cylinder and a gases cleaning system. The self-absorption curve got ready starting from the device. (Author)

  16. Immuno-vectorization of radioelements emitters of alpha particles: a new therapy in cancerology

    International Nuclear Information System (INIS)

    Bourgeois, M.

    2007-05-01

    The radio-immunotherapy is an anti cancerous therapy which consists in vectorising with immuno-specific agents very radio toxic radioelements on tumors or in their environment to destroy them. The first part of this report presents the different characteristics of antibodies as well as their means of production under monoclonal shapes specifically steered against a tumoral antigen of interest. The second part of this report replaces the importance of the immunological vectors in the context of the nuclear medicine. It is notably described that the different methods which allow to radio-label the vector, as well as the different ways of optimization which were envisaged to improve the targeting of radioelements on a tumor. These different developments allow to define the potential place of the alpha radio-immunotherapy in treatments and so re-place the interest of the experimental part. If the radio-immunotherapy, using beta emitters isotopes as the 131 iodine or the 90 yttrium, is today current in anti cancerous therapy, it finds limits because of the disintegration characteristics of the isotopes it uses. Indeed, compared with alpha particles, the beta particles deposit less energy by unit of length in the crossed material.The experimental part of this report aims at studying the feasibility of the coupling between an immunological vector and an alpha emitter isotope.The different tests led on the bismuth 213, the bismuth 212, the lead 212 and the astatine 211 demonstrated that the fixation of these radionuclides was possible. This research theme is strengthened by the construction in Nantes of a cyclotron with high energy ( A.R.R.O.N.A.X.) and the optimization of the obtained promising results should allow a therapeutic use in oncology of the alpha radio-immunotherapy. (N.C.)

  17. Gamma flux responsive self-powered detector with a tubular emitter

    International Nuclear Information System (INIS)

    Goldstein, N.P.; Todt, W.H.

    1982-01-01

    A gamma-sensitive flux detector comprises tubular emitter, an insulating core within the emitter and an insulating layer about the emitter, and a tubular conductive collector electrode about the insulating layer. The emitter material may be platinum, lead, bismuth, tantalum, tungsten; platinum preferred

  18. Improved Delayed-Neutron Spectroscopy Using Trapped Ions

    Energy Technology Data Exchange (ETDEWEB)

    Norman, Eric

    2018-04-24

    The neutrons emitted following the  decay of fission fragments (known as delayed neutrons because they are emitted after fission on a timescale of the -decay half-lives) play a crucial role in reactor performance and control. Reviews of delayed-neutron properties highlight the need for high-quality data for a wide variety of delayed-neutron emitters to better understand the timedependence and energy spectrum of the neutrons as these properties are essential for a detailed understanding of reactor kinetics needed for reactor safety and to understand the behavior of these reactors under various accident and component-failure scenarios. For fast breeder reactors, criticality calculations require accurate delayed-neutron energy spectra and approximations that are acceptable for light-water reactors such as assuming the delayed-neutron and fission-neutron energy spectra are identical are not acceptable and improved -delayed neutron data is needed for safety and accident analyses for these reactors. With improved nuclear data, the delayedneutrons flux and energy spectrum could be calculated from the contributions from individual isotopes and therefore could be accurately modeled for any fuel-cycle concept, actinide mix, or irradiation history. High-quality -delayed neutron measurements are also critical to constrain modern nuclear-structure calculations and empirical models that predict the decay properties for nuclei for which no data exists and improve the accuracy and flexibility of the existing empirical descriptions of delayed neutrons from fission such as the six-group representation

  19. Emergence of White Organic Light-Emitting Diodes Based on Thermally Activated Delayed Fluorescence

    Directory of Open Access Journals (Sweden)

    Peng Xiao

    2018-02-01

    Full Text Available Recently, thermally activated delayed fluorescence (TADF organic light-emitting diodes (OLEDs have attracted both academic and industrial interest due to their extraordinary characteristics, such as high efficiency, low driving voltage, bright luminance, lower power consumption and potentially long lifetime. In this invited review, the fundamental concepts of TADF have been firstly introduced. Then, main approaches to realize WOLEDs based on TADF have been summarized. More specifically, the recent development of WOLEDs based on all TADF emitters, WOLEDs based on TADF and conventional fluorescence emitters, hybrid WOLEDs based on blue TADF and phosphorescence emitters and WOLEDs based on TADF exciplex host and phosphorescence dopants is highlighted. In particular, design strategies, device structures, working mechanisms and electroluminescent processes of the representative WOLEDs based on TADF are reviewed. Finally, challenges and opportunities for further enhancement of the performance of WOLEDs based on TADF are presented.

  20. Emittance Growth in the NLCTA First Chicane

    International Nuclear Information System (INIS)

    Sun, Yipeng

    2011-01-01

    In this paper, the emittance growth in the NLCTA (Next Linear Collider Test Accelerator) first chicane region is evaluated by simulation studies. It is demonstrated that the higher order fields of the chicane dipole magnet and the dipole corrector magnet (which is attached on the quadrupoles) are the main contributions for the emittance growth, especially for the case with a large initial emittance (γε 0 = 5 (micro)m for instance). These simulation results agree with the experimental observations.

  1. A combined emitter threat assessment method based on ICW-RCM

    Science.gov (United States)

    Zhang, Ying; Wang, Hongwei; Guo, Xiaotao; Wang, Yubing

    2017-08-01

    Considering that the tradition al emitter threat assessment methods are difficult to intuitively reflect the degree of target threaten and the deficiency of real-time and complexity, on the basis of radar chart method(RCM), an algorithm of emitter combined threat assessment based on ICW-RCM (improved combination weighting method, ICW) is proposed. The coarse sorting is integrated with fine sorting in emitter combined threat assessment, sequencing the emitter threat level roughly accordance to radar operation mode, and reducing task priority of the low-threat emitter; On the basis of ICW-RCM, sequencing the same radar operation mode emitter roughly, finally, obtain the results of emitter threat assessment through coarse and fine sorting. Simulation analyses show the correctness and effectiveness of this algorithm. Comparing with classical method of emitter threat assessment based on CW-RCM, the algorithm is visual in image and can work quickly with lower complexity.

  2. Charged particle induced delayed X-rays (DEX) for the analysis of intermediate and heavy elements

    Science.gov (United States)

    Pillay, A. E.; Erasmus, C. S.; Andeweg, A. H.; Sellschop, J. P. F.; Annegarn, H. J.; Dunn, J.

    1988-12-01

    The emission of K X-rays from proton-rich and metastable radionuclides, following proton activation of the stable isotopes of the elements of interest, has not been widely used as a means of analysis. The thrust of this paper proposes a nuclear technique using delayed X-rays for the analysis of low concentrations of intermediate and heavy elements. The method is similar to the delayed gamma-ray technique. Proton bombardment induces mainly (p, n) reactions whereas the delayed X-rays originate largely from e --capture and isomeric transition. Samples of rare earth and platinum group elements (PGE), in the form of compacted powders, were irradiated with an 11 MeV proton beam and delayed X-rays detected with a 100 mm 2 Ge detector. Single element spectra for a range of rare earths and PGEs are presented. Analytical conditions are demonstrated for Pd in the range 0.1-5%. Spectra from actual geological samples of a PGE ore, preconcentrated by fire-assay, and monazite are presented. All six platinum group elements are visible and interference-free in a single spectrum, a marked advance on other nuclear techniques for these elements, including PIXE and neutron activation analysis (NAA).

  3. One-proton emission from the Li6Λ hypernucleus

    Science.gov (United States)

    Oishi, Tomohiro

    2018-02-01

    One-proton (1 p ) radioactive emission under the influence of the Λ0-hyperon inclusion is discussed. I investigate the hyper-1 p emitter, Li6Λ, with a time-dependent three-body model. Two-body interactions for α -proton and α -Λ0 subsystems are determined consistently to their resonant and bound energies, respectively. For a proton-Λ0 subsystem, a contact interaction, which can be linked to the vacuum-scattering length of the proton-Λ0 scattering, is employed. A noticeable sensitivity of the 1 p -emission observables to the scattering length of the proton-Λ0 interaction is shown. The Λ0-hyperon inclusion leads to a remarkable fall of the 1 p -resonance energy and width from the hyperonless α -proton resonance. For some empirical values of the proton-Λ0 scattering length, the 1 p -resonance width is suggested to be of the order of 0.1 -0.01 MeV. Thus, the 1 p emission from Li6Λ may occur in the time scale of 10-20-10-21 seconds, which is sufficiently shorter than the self-decay lifetime of Λ0,10-10 seconds. By taking the spin-dependence of the proton-Λ0 interaction into account, a remarkable split of the Jπ=1- and 2- 1 p -resonance states is predicted. It is also suggested that, if the spin-singlet proton-Λ0 interaction is sufficiently attractive, the 1 p emission from the 1- ground state is forbidden. From these results, I conclude that the 1 p emission can be a suitable phenomenon to investigate the basic properties of the hypernuclear interaction, for which a direct measurement is still difficult.

  4. NMR detection of short-lived β-emitter {sup 12}N implanted in water

    Energy Technology Data Exchange (ETDEWEB)

    Sugihara, T., E-mail: sugihara@vg.phys.sci.osaka-u.ac.jp; Mihara, M.; Shimaya, J.; Matsuta, K.; Fukuda, M.; Ohno, J.; Tanaka, M.; Yamaoka, S.; Watanabe, K.; Iwakiri, S.; Yanagihara, R.; Tanaka, Y.; Du, H.; Onishi, K.; Kambayashi, S.; Minamisono, T. [Osaka University, Department of Physics (Japan); Nishimura, D. [Tokyo University of Science, Department of Physics (Japan); Izumikawa, T. [Niigata University, Radioisotope Center (Japan); Ozawa, A. [University of Tsukuba, Department of Physics (Japan); Ishibashi, Y. [RIKEN Nishina Center for Accelerator-Based Science (Japan); and others

    2017-11-15

    The beta-detected nuclear magnetic resonance (β-NMR) in liquid H{sub 2}O has been observed for the first time using a short-lived β-ray emitter {sup 12}N (I{sup π} = 1{sup +},T{sub 1/2}=11 ms). A nuclear spin polarized {sup 12}N beam with an energy of about 20 MeV/nucleon was implanted into an enclosed water sample. About 50 % of implanted {sup 12}N ions maintained nuclear polarization and exhibited a β-NMR spectrum. The chemical shift of {sup 12}N in H{sub 2}O relative to {sup 12}N in Pt was deduced to be −(3.6±0.5) × 10{sup 2} ppm.

  5. SOLAR WIND PROTONS AT 1 AU: TRENDS AND BOUNDS, CONSTRAINTS AND CORRELATIONS

    Energy Technology Data Exchange (ETDEWEB)

    Hellinger, Petr; Trávníček, Pavel M., E-mail: petr.hellinger@asu.cas.cz [Astronomical Institute, AS CR, Bocni II/1401,CZ-14100 Prague (Czech Republic)

    2014-03-20

    The proton temperature anisotropy in the solar wind exhibits apparent bounds which are compatible with the theoretical constraints imposed by temperature-anisotropy-driven kinetic instabilities. Recent statistical analyses based on conditional averaging indicate that near these theoretical constraints the solar wind protons typically have enhanced temperatures and a weaker collisionality. Here we carefully analyze the solar wind data and show that these results are a consequence of superposition of multiple correlations in the solar wind, namely, they mostly result from the correlation between the proton temperature and the solar wind velocity and from the superimposed anti-correlation between the proton temperature anisotropy and the proton parallel beta in the fast solar wind. Colder and more collisional data are distributed around temperature isotropy whereas hotter and less collisional data have a wider range of the temperature anisotropy anti-correlated with the proton parallel beta with signatures of constraints owing to the temperature-anisotropy-driven instabilities. However, most of the hot and weakly collisional data, including the hottest and least collisional ones, lies far from the marginal stability regions. Consequently, we conclude that there is no clear relation between the enhanced temperatures and instability constraints and that the conditional averaging used for these analyses must be used carefully and need to be well tested.

  6. 213Bi-DOTATOC receptor-targeted alpha-radionuclide therapy induces remission in neuroendocrine tumours refractory to beta radiation: a first-in-human experience

    International Nuclear Information System (INIS)

    Kratochwil, C.; Giesel, F.L.; Mier, W.; Haberkorn, U.; Bruchertseifer, F.; Apostolidis, C.; Morgenstern, A.; Boll, R.; Murphy, K.

    2014-01-01

    Radiopeptide therapy using a somatostatin analogue labelled with a beta emitter such as 90 Y/ 177 Lu-DOTATOC is a new therapeutic option in neuroendocrine cancer. Alternative treatments for patients with refractory disease are rare. Here we report the first-in-human experience with 213 Bi-DOTATOC targeted alpha therapy (TAT) in patients pretreated with beta emitters. Seven patients with progressive advanced neuroendocrine liver metastases refractory to treatment with 90 Y/ 177 Lu-DOTATOC were treated with an intraarterial infusion of 213 Bi-DOTATOC, and one patient with bone marrow carcinosis was treated with a systemic infusion of 213 Bi-DOTATOC. Haematological, kidney and endocrine toxicities were assessed according to CTCAE criteria. Radiological response was assessed with contrast-enhanced MRI and 68 Ga-DOTATOC-PET/CT. More than 2 years of follow-up were available in seven patients. The biodistribution of 213 Bi-DOTATOC was evaluable with 440 keV gamma emission scans, and demonstrated specific tumour binding. Enduring responses were observed in all treated patients. Chronic kidney toxicity was moderate. Acute haematotoxicity was even less pronounced than with the preceding beta therapies. TAT can induce remission of tumours refractory to beta radiation with favourable acute and mid-term toxicity at therapeutic effective doses. (orig.)

  7. FEASIBILITY OF POSITRON EMISSION TOMOGRAPHY OF DOSE DISTRIBUTION IN PROTON BEAM CANCER THERAPY

    International Nuclear Information System (INIS)

    BEEBE-WANG, J.J.; DILMANIAN, F.A.; PEGGS, S.G.; SCHLYEER, D.J.; VASKA, P.

    2002-01-01

    Proton therapy is a treatment modality of increasing utility in clinical radiation oncology mostly because its dose distribution conforms more tightly to the target volume than x-ray radiation therapy. One important feature of proton therapy is that it produces a small amount of positron-emitting isotopes along the beam-path through the non-elastic nuclear interaction of protons with target nuclei such as 12 C, 14 N, and 16 O. These radioisotopes, mainly 11 C, 13 N and 15 O, allow imaging the therapy dose distribution using positron emission tomography (PET). The resulting PET images provide a powerful tool for quality assurance of the treatment, especially when treating inhomogeneous organs such as the lungs or the head-and-neck, where the calculation of the dose distribution for treatment planning is more difficult. This paper uses Monte Carlo simulations to predict the yield of positron emitters produced by a 250 MeV proton beam, and to simulate the productions of the image in a clinical PET scanner

  8. Measurements of Thermal Emittance for Cesium Telluride Photocathodes at PITZ

    CERN Document Server

    Miltchev, V; Grabosch, H J; Han, J H; Krasilnikov, M; Oppelt, A; Petrosian, B; Staykov, L; Stephan, F

    2005-01-01

    The thermal emittance determines the lower emittance limit and its measurement is of high importance to understand the ultimate injector performance. In this contribution we present results of thermal emittance measurements under rf operation conditions for various Cs2Te cathodes and different accelerating gradients. Measurements of thermal emittance scaling with the cathode laser spot size are presented and analysed. The significance of the Schottky effect in the emittance formation process is discussed.

  9. Optics measurement and correction during beam acceleration in the Relativistic Heavy Ion Collider

    Energy Technology Data Exchange (ETDEWEB)

    Liu, C. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Marusic, A. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Minty, M. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.

    2014-09-09

    To minimize operational complexities, setup of collisions in high energy circular colliders typically involves acceleration with near constant β-functions followed by application of strong focusing quadrupoles at the interaction points (IPs) for the final beta-squeeze. At the Relativistic Heavy Ion Collider (RHIC) beam acceleration and optics squeeze are performed simultaneously. In the past, beam optics correction at RHIC has taken place at injection and at final energy with some interpolation of corrections into the acceleration cycle. Recent measurements of the beam optics during acceleration and squeeze have evidenced significant beta-beats which if corrected could minimize undesirable emittance dilutions and maximize the spin polarization of polarized proton beams by avoidance of higher-order multipole fields sampled by particles within the bunch. In this report the methodology now operational at RHIC for beam optics corrections during acceleration with simultaneous beta-squeeze will be presented together with measurements which conclusively demonstrate the superior beam control. As a valuable by-product, the corrections have minimized the beta-beat at the profile monitors so reducing the dominant error in and providing more precise measurements of the evolution of the beam emittances during acceleration.

  10. Electron emitter pulsed-type cylindrical IEC

    International Nuclear Information System (INIS)

    Miley, G.H.; Gu, Y.; Stubbers, R.; Zich, R.; Anderl, R.; Hartwell, J.

    1997-01-01

    A cylindrical version of the single grid Inertial Electrostatic Confinement (IEC) device (termed the C-device) has been developed for use as a 2.5-MeV D-D fusion neutron source for neutron activation analysis. The C-device employs a hollow-tube type cathode with similar anodes backed up by ''reflector'' dishes. The resulting discharge differs from a conventional hollow cathode discharge, by creating an explicit ion beam which is ''pinched'' in the cathode region. Resulting fusion reactions generate ∼10 6 neutron/s. A pulsed version is under development for applications requiring higher fluxes. Several pulsing techniques are under study, including an electron emitter (e-emitter) assisted discharge in a thorated tungsten wire emitter located behind a slotted area in the reflector dishes. Pulsing is initiated after establishing a low power steady-state discharge by pulsing the e-emitter current using a capacitor switch type circuit. The resulting electron jet, coupled with the discharge by the biased slot array, creates a strong pulse in the pinched ion beam. The pulse length/repetition rate are controlled by the e-emitter pulse circuit. Typical parameters in present studies are ∼30micros, 10Hz and 1-amp ion current. Corresponding neutron measurements are an In-foil type activation counter for time averaged rates. Results for a wide variety of operating conditions are presented

  11. Emittance and beam size distortion due to linear coupling

    International Nuclear Information System (INIS)

    Parzen, G.

    1993-01-01

    At injection, the presence of linear coupling may result in an increased beam emittance and in increased beam dimensions. Results for the emittance in the presence of linear coupling will be found. These results for the emittance distortion show that the harmonics of the skew quadrupole field close to ν x + ν y are the important harmonics. Results will be found for the important driving terms for the emittance distortion. It will be shown that if these driving terms are corrected, then the total emittance is unchanged, var-epsilon x + var-epsilon y = var-epsilon 1 + var-epsilon 2 . Also, the increase in the beam dimensions will be limited to a factor which is less than 1.414. If the correction is good enough, see below for details, one can achieve var-epsilon 1 = var-epsilon x , var-epsilon 2 = var-epsilon where var-epsilon 1 , var-epsilon 2 are the emittances in the presence of coupling, and the beam dimensions are unchanged. Global correction of the emittance and beam size distortion appears possible

  12. The Quantum Efficiency and Thermal Emittance of Metal Photocathodes

    International Nuclear Information System (INIS)

    Dowell, D.

    2009-01-01

    Modern electron beams have demonstrated the brilliance needed to drive free electron lasers at x-ray wavelengths, with the principle improvements occurring since the invention of the photocathode gun. The state-of-the-art normalized emittance electron beams are now becoming limited by the thermal emittance of the cathode. In both DC and RF photocathode guns, details of the cathode emission physics strongly influence the quantum efficiency and the thermal emittance. Therefore improving cathode performance is essential to increasing the brightness of beams. It is especially important to understand the fundamentals of cathode quantum efficiency and thermal emittance. This paper investigates the relationship between the quantum efficiency and the thermal emittance of metal cathodes using the Fermi-Dirac model for the electron distribution. We derive the thermal emittance and its relationship to the quantum efficiency, and compare our results to those of others

  13. Etude de la mesure des emittances transverses d'un faisceau par la methode des gradients. Application au cas d'une focalisation par solenoide

    CERN Document Server

    M'Garrech, S

    2002-01-01

    Within the framework of the ALTO project (Linear Accelerator near the Orsay Tandem), IPNO will recover the LAL station NEPAL, which will be used as the ALTO injecting system. To calculate the beam optics through the linear accelerator, it is necessary to determine the electron beam emittance at the exit of the buncher station. There are several methods to determine this emittance: direct methods, like the Pepper Pot technique, and indirect ones, like the three distances method and the three gradients one. The latter requires a variable optic element (quadrupole, solenoid...). In the case of the use of a solenoid, the horizontal and vertical motions are coupled, which implies an additional difficulty for the analysis of the measurements. The main goal of this report is to identify and to solve these mathematical difficulties, so as to determine at last the initial emittance. The treated example comes from a paper by R.Chehab et al [12], the code used is BETA, and resolution is done using the last square method...

  14. Cooperative spontaneous emission of nano-emitters with inter-emitter coupling in a leaky microcavity

    International Nuclear Information System (INIS)

    Hong, Suc-Kyoung; Nam, Seog Woo; Yang, Hyung Jin

    2015-01-01

    We study the spontaneous emission from a few two-level nano-emitters placed in a leaky microcavity with Lorentzian spectral density near a critically damped regime. Collective features of the spontaneous emission are investigated by numerical analysis of the excitation dynamics when initially one nano-emitter is totally excited but we do not know which one. The results show that there are three decay rates in the excitation dynamics, two for simple exponential decays and one for damped oscillatory decay. The excitation dynamics is found to critically depend on the regime of the system. It is shown that the spontaneous emission is enhanced or suppressed depending on whether the system is in the underdamped or overdamped regime, respectively. On the other hand, the cooperative spontaneous emission is suppressed in the underdamped while it is enhanced in the overdamped regime. Furthermore, the effect of the direct inter-emitter coupling on the breaking of the cooperativeness of the spontaneous emission is shown as well. (paper)

  15. $\\sin(2\\beta)$ with $B^0 \\rightarrow\\!J/\\!\\psi K_\\text{S}$ at the LHCb experiment

    CERN Multimedia

    Niet, Ramon

    2015-01-01

    The poster presents the recent measurement of $\\sin(2\\beta)$ using $B^0$ decays to the $J/\\!\\psi K_\\text{S}$ final state. The measurement is based on a dataset corresponding to an integrated luminosity of 3.0$\\,\\text{fb}^{-1}$ collected with the LHCb experiment in proton-proton collisions at center-of-mass energies of 7 and 8 TeV. To control penguin pollutions in the determination of $\\sin(2\\beta)$, $B_s^0$ decays to the same final state can be analysed. The results of the corresponding analysis are presented as well.

  16. Statistical effects in beta-delayed neutron emission from fission product nuclides

    International Nuclear Information System (INIS)

    McElroy, R.D. Jr.

    1986-01-01

    The delayed neutron spectra for the precursors Rb-93, 94, 95, 96, 97 and Cs-145 were measured by use of the on-line isotope separator facility TRISTAN and a time-of-flight (TOF) spectrometer. Flight paths were used that provided, for energies below 70 keV, a FWHM energy resolution between 2 and 4 percent. Each spectrum showed discrete neutron peaks below 156 keV, with as many as 26 in the Rb-95 spectra. Level densities near the neutron binding energy in the neutron-emitting nuclide were deduced using a missing-level indicator based on a Porter-Thomas distribution of neutron peak intensities. The resulting level density data were compared to the predictions of the Gilbert and Cameron formulism and to those of Dilg, Schantl, Vonach and Uhl. Comparisons were made between the empirically-based level parameter a and the values predicted by each model for Sr-93, 94, 95, 97 and Ba-145. The two models appear, within the uncertainties, to be equally capable of describing these neutron-rich nuclides and equally as capable for them as they are for nuclides in the valley of beta stability. Measurements of the neutron strength function are sometimes possible with the present TOF system for neutron decays with competing neutron branches to levels in the grandchild nucleus. A value for the d-wave strength function of Sr-96 is found to be (4.2 +- 1.1)/10 4 . Improvements in the TOF system, allowing the measurement of the neutron strength function for the more general case, are discussed. 72 refs., 56 figs., 16 tabs

  17. Beta decay of 72Co and excited levels in 72Ni

    International Nuclear Information System (INIS)

    Grzywacz, R.; Rykaczewski, K.; Sawicka, M.; Pfuetzner, M.; Daugas, J.M.; Belier, G.; Sauvestre, J.E.; Meot, V.; Roig, O.; Giovinazzo, J.; Grawe, H.; Mayet, P.; Matea, I.; Georgiev, G.; Lewitowicz, M.; Olivieira, F. de; Stodel, C.; Saint-Laurent, M. G.; Stanoiu, M.; Verney, D.

    2003-01-01

    An experiment was performed at GANIL to observe isomeric- and beta-delayed gamma rays from very neutron-rich nuclei around 74Ni. Fragmentation products of the 86Kr beam at 58 AMeV were studied using new devices: the LISE 2000 spectrometer and detectors from the EXOGAM germanium array. The primary aim of the experiment was to find the 8+ microsecond isomer in 76Ni and to perform beta decay spectroscopy of Co nuclei. We have successfully measured the beta delayed gammas from the decay of 72Co to 72Ni. The energies for the lowest excited states in 72Ni are proposed, with the first 2+ state at 1096 keV. These findings suggest a solution of the problem of the disappearance of the 8+ isomer in 72Ni. We also measured beta decay of other neutron-rich Co isotopes including 70Co. First evidence was found for a new short lived isomer, most likely the Iπ=8+ state, in 76Ni

  18. Proton irradiation and endometriosis

    International Nuclear Information System (INIS)

    Wood, D.H.; Yochmowitz, M.G.; Salmon, Y.L.; Eason, R.L.; Boster, R.A.

    1983-01-01

    It was found that female rhesus monkeys given single total-body exposures of protons of varying energies developed endometriosis at a frequency significantly higher than that of nonirradiated animals of the same age. The minimum latency period was determined to be 7 years after the proton exposure. The doses and energies of the radiation received by the experimental animals were within the range that could be received by an aircrew member in near-earth orbit during a random solar flare event. It is concluded that endometriosis should be a consideration in assessing the risk of delayed radiation effects in female crew members. 15 references

  19. {sup 213}Bi-DOTATOC receptor-targeted alpha-radionuclide therapy induces remission in neuroendocrine tumours refractory to beta radiation: a first-in-human experience

    Energy Technology Data Exchange (ETDEWEB)

    Kratochwil, C.; Giesel, F.L.; Mier, W.; Haberkorn, U. [University Hospital Heidelberg, Department of Nuclear Medicine, Heidelberg (Germany); Bruchertseifer, F.; Apostolidis, C.; Morgenstern, A. [European Commission, Institute for Transuranium Elements, Karlsruhe (Germany); Boll, R.; Murphy, K. [Oak Ridge National Laboratory, Oak Ridge, TN (United States)

    2014-11-15

    Radiopeptide therapy using a somatostatin analogue labelled with a beta emitter such as {sup 90}Y/{sup 177}Lu-DOTATOC is a new therapeutic option in neuroendocrine cancer. Alternative treatments for patients with refractory disease are rare. Here we report the first-in-human experience with {sup 213}Bi-DOTATOC targeted alpha therapy (TAT) in patients pretreated with beta emitters. Seven patients with progressive advanced neuroendocrine liver metastases refractory to treatment with {sup 90}Y/{sup 177}Lu-DOTATOC were treated with an intraarterial infusion of {sup 213}Bi-DOTATOC, and one patient with bone marrow carcinosis was treated with a systemic infusion of {sup 213}Bi-DOTATOC. Haematological, kidney and endocrine toxicities were assessed according to CTCAE criteria. Radiological response was assessed with contrast-enhanced MRI and {sup 68}Ga-DOTATOC-PET/CT. More than 2 years of follow-up were available in seven patients. The biodistribution of {sup 213}Bi-DOTATOC was evaluable with 440 keV gamma emission scans, and demonstrated specific tumour binding. Enduring responses were observed in all treated patients. Chronic kidney toxicity was moderate. Acute haematotoxicity was even less pronounced than with the preceding beta therapies. TAT can induce remission of tumours refractory to beta radiation with favourable acute and mid-term toxicity at therapeutic effective doses. (orig.)

  20. Diamondoid monolayers as electron emitters

    Science.gov (United States)

    Yang, Wanli [El Cerrito, CA; Fabbri, Jason D [San Francisco, CA; Melosh, Nicholas A [Menlo Park, CA; Hussain, Zahid [Orinda, CA; Shen, Zhi-Xun [Stanford, CA

    2012-04-10

    Provided are electron emitters based upon diamondoid monolayers, preferably self-assembled higher diamondoid monolayers. High intensity electron emission has been demonstrated employing such diamondoid monolayers, particularly when the monolayers are comprised of higher diamondoids. The application of such diamondoid monolayers can alter the band structure of substrates, as well as emit monochromatic electrons, and the high intensity electron emissions can also greatly improve the efficiency of field-effect electron emitters as applied to industrial and commercial applications.

  1. Nanodiamond Emitters of Single Photons

    Directory of Open Access Journals (Sweden)

    Vlasov I.I.

    2015-01-01

    Full Text Available Luminescence properties of single color centers were studied in nanodiamonds of different origin. It was found that single photon emitters could be realized even in molecularsized diamond (less than 2 nm capable of housing stable luminescent center “silicon-vacancy.” First results on incorporation of single-photon emitters based on luminescent nanodiamonds in plasmonic nanoantennas to enhance the photon count rate and directionality, diminish the fluorescence decay time, and provide polarization selectivity are presented.

  2. Tolerances for the vertical emittance in damping rings

    International Nuclear Information System (INIS)

    Raubenheimer, T.O.

    1991-11-01

    Future damping rings for linear colliders will need to have very small vertical emittances. In the limit of low beam current, the vertical emittance is primarily determined by the vertical dispersion and the betatron coupling. In this paper, the contributions to these effects from random misalignments are calculated and tolerances are derived to limit the vertical emittance with a 95% confidence level. 10 refs., 5 figs

  3. Beam emittance measurements on multicusp ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Sarstedt, M.; Lee, Y.; Leung, K.N. [and others

    1995-08-01

    Multicusp ion sources are used for various applications. Presently, the implementation of this type of ion source planned for the development of an ion beam lithography machine, which will be used for the projection of sub-0.2 {mu}m patterns onto a wafer substrate. Since, for this application, a very good beam quality and a small ion energy spread are required, emittance measurements have been performed on a multicusp ion source for various source conditions. It is shown that the installation of proper capacitors between the extraction electrodes is necessary to avoid rf-pickup, which otherwise leads to a distortion of the beam emittance. The influence of the magnetic filter field on the beam emittance has been investigated, and the beam emittance of a dc filament-discharge plasma has also been compared to that of an rf-generated plasma.

  4. Beam emittance measurements on multicusp ion sources

    International Nuclear Information System (INIS)

    Sarstedt, M.; Lee, Y.; Leung, K.N.

    1995-08-01

    Multicusp ion sources are used for various applications. Presently, the implementation of this type of ion source planned for the development of an ion beam lithography machine, which will be used for the projection of sub-0.2 μm patterns onto a wafer substrate. Since, for this application, a very good beam quality and a small ion energy spread are required, emittance measurements have been performed on a multicusp ion source for various source conditions. It is shown that the installation of proper capacitors between the extraction electrodes is necessary to avoid rf-pickup, which otherwise leads to a distortion of the beam emittance. The influence of the magnetic filter field on the beam emittance has been investigated, and the beam emittance of a dc filament-discharge plasma has also been compared to that of an rf-generated plasma

  5. Test results on two thermionic converters with cermet emitters

    International Nuclear Information System (INIS)

    Saunders, M.; Danielson, L.; Huffman, F.

    1983-01-01

    An emitter made of a directionally solidified Mo-Al 2 O 3 , Cr 2 O 3 eutectic was provided by Eindhoven University of Technology in Eindhoven, The Netherlands. Although the high temperature braze cycle used in bonding this electrode to the emitter substrate destroyed its characteristic needle microstructure, the converter gave good performance. Apparently, chemical species evaporated from the emitter onto the collector provided a low collector work function. The resulting low barrier indices suggest that this surface is a promising emitter

  6. Detection of the sulfhydryl groups in proteins with slow hydrogen exchange rates and determination of their proton/deuteron fractionation factors using the deuterium-induced effects on the 13C(beta) NMR signals.

    Science.gov (United States)

    Takeda, Mitsuhiro; Jee, JunGoo; Terauchi, Tsutomu; Kainosho, Masatsune

    2010-05-05

    A method for identifying cysteine (Cys) residues with sulfhydryl (SH) groups exhibiting slow hydrogen exchange rates has been developed for proteins in aqueous media. The method utilizes the isotope shifts of the C(beta) chemical shifts induced by the deuteration of the SH groups. The 18.2 kDa E. coli peptidyl prolyl cis-trans isomerase b (EPPIb), which was selectively labeled with [3-(13)C;3,3-(2)H(2)]Cys, showed much narrower line widths for the (13)C(beta) NMR signals, as compared to those of the proteins labeled with either [3-(13)C]Cys or (3R)-[3-(13)C;3-(2)H]Cys. The (13)C(beta) signals of the two Cys residues of EPPIb, i.e. Cys-31 and Cys-121, labeled with [3-(13)C;3,3-(2)H(2)]Cys, split into four signals in H(2)O/D(2)O (1:1) at 40 degrees C and pH 7.5, indicating that the exchange rates of the side-chain SH's and the backbone amides are too slow to average the chemical shift differences of the (13)C(beta) signals, due to the two- and three-bond isotope shifts. By virtue of the well-separated signals, the proton/deuteron fractional factors for both the SH and amide groups of the two Cys residues in EPPIb could be directly determined, as approximately 0.4-0.5 for [SD]/[SH] and 0.9-1.0 for [ND]/[NH], by the relative intensities of the NMR signals for the isotopomers. The proton NOE's of the two slowly exchanging SH's were clearly identified in the NOESY spectra and were useful for the determining the local structure of EPPIb around the Cys residues.

  7. Basic leaching tests for pure beta long-lived emitters in radioactive wastes

    International Nuclear Information System (INIS)

    Murillo, R.; Almodovar, A.; Gonzalez de la Huebra, A.

    1995-09-01

    Specimens for the two first leaching stages were manufactured using samples of virgin resins saturated in simulated conditions. EPIFLOC 21H resin was 50% saturated with NaCl and DUOLITE ARM-9381 resin was 100% saturated with NaCl+H 3 BO 3 . Previously both resins were doped with Ni-63 and Sr-90. As far as the third leaching stage is concerning, samples of real resins from two Spanish nuclear power plants were used for manufacturing of leaching specimens. Because Sr-90 and Ni-63 radioactivity in these samples was not high enough to be detectable in leachate, samples were additionally loaded with Sr-90 and Ni-63 before mixing with cement. Leaching procedure was adapted to the French one (the same duration of leaching renewal steps and cumulative leaching time and also the same analytical preparation for chemical and radiochemical analysis). Specimens were hanged into leachant with nylon yarn and were surrounded by a leachant layer of 3 cm thickness. Additionally to Sr-90 and Ni-63, the main chemical elements present in cements used for manufacturing of specimens were analyzed in leachates from the two first leaching stages and the main gamma emitters present in the samples of real resins were analyzed in leachates from the third leaching stages. (Author)

  8. Transverse emittance growth in staged laser-wakefield acceleration

    Directory of Open Access Journals (Sweden)

    T. Mehrling

    2012-11-01

    Full Text Available We present a study on the emittance evolution of electron bunches, externally injected into laser-driven plasma waves using the three-dimensional particle-in-cell (PIC code OSIRIS. Results show order-of-magnitude transverse emittance growth during the injection process, if the electron bunch is not matched to its intrinsic betatron motion inside the wakefield. This behavior is supported by analytic theory reproducing the simulation data to a percent level. The length over which the full emittance growth develops is found to be less than or comparable to the typical dimension of a single plasma module in current multistage designs. In addition, the analytic theory enables the quantitative prediction of emittance degradation in two consecutive accelerators coupled by free-drift sections, excluding this as a scheme for effective emittance-growth suppression, and thus suggests the necessity of beam-matching sections between acceleration stages with fundamental implications on the overall design of staged laser-wakefield accelerators.

  9. Emittance measurements in Grumman 1 MeV beamline

    International Nuclear Information System (INIS)

    Debiak, T.; Gammel, G.; Melnychuk, S.

    1992-01-01

    The emittance of a 30 keV H - beam has been measured with an Allison type electrostatic analyser at two positions separated by 85 cm along the Grumman 1 MeV beamline LEBT at low currents (about 4 mA, no Cs 2 O additive in the source) and at higher currents (10-15 mA, with Cs 2 O additive in the source). No emittance growth was observed between the two positions, but, at the higher current level, the emittance was about 60% higher than at the low current level (Σ n ,rms = .0045 π cm-mrad vs. 0070 π cm-mrad). Argon was then introduced up to a partial pressure of 4x10 -5 torr, and the emittance decreased back to a range corresponding to that found at the lower currents. However, beam noise was observed at the downstream position, and there is evidence for a small amount of emittance growth (<20%) between the two positions

  10. Beta-gamma contaminated solid waste incinerator facility

    International Nuclear Information System (INIS)

    Hootman, H.E.

    1979-10-01

    This technical data summary outlines a reference process to provide a 2-stage, 400 lb/hour incinerator to reduce the storage volume of combustible process waste contaminated with low-level beta-gamma emitters in response to DOE Manual 0511. This waste, amounting to more than 200,000 ft 3 per year, is presently buried in trenches in the burial ground. The anticipated storage volume reduction from incineration will be a factor of 20. The incinerator will also dispose of 150,000 gallons of degraded solvent from the chemical separations areas and 5000 gallons per year of miscellaneous nonradioactive solvents which are presently being drummed for storage

  11. Delayed Neutron Fraction (beta-effective) Calculation for VVER 440 Reactor

    International Nuclear Information System (INIS)

    Hascik, J.; Michalek, S.; Farkas, G.; Slugen, V.

    2008-01-01

    Effective delayed neutron fraction (β eff ) is the main parameter in reactor dynamics. In the paper, its possible determination methods are summarized and a β eff calculation for a VVER 440 power reactor as well as for training reactor VR1 using stochastic transport Monte Carlo method based code MCNP5 is made. The uncertainties in determination of basic delayed neutron parameters lead to the unwished conservatism in the reactor control system design and operation. Therefore, the exact determination of the β eff value is the main requirement in the field of reactor dynamics. The interest in the delayed neutron data accuracy improvement started to increase at the end of 80-ties and the beginning of 90-ties, after discrepancies among the results of experiments and measurements what do you mean differences between different calculation approaches and experimental results. In consequence of difficulties in β eff experimental measurement, this value in exact state is determined by calculations. Subsequently, its reliability depends on the calculation method and the delayed neutron data used. An accurate estimate of β eff is essential for converting reactivity, as measured in dollars, to an absolute reactivity and/or to an absolute k eff . In the past, k eff has been traditionally calculated by taking the ratio of the adjoint- and spectrum-weighted delayed neutron production rate to the adjoint- and spectrum-weighted total neutron production rate. An alternative method has also been used in which β eff is calculated from simple k-eigenvalue solutions. The summary of the possible β eff determination methods can be found in this work and also a calculation of β eff first for the training reactor VR1 in one operation state and then for VVER 440 power reactor in two different operation states are made using the prompt method, by MCNP5 code.(author)

  12. Gamow-Teller beta decay of proton-rich nuclei

    International Nuclear Information System (INIS)

    Klepper, O.; Rykaczewski, K.

    1990-11-01

    The beta decays of 48 Mn and of even-even nuclei near the double shell-closures at 100 Sn and 146 Gd are currently investigated at the GSI on-line mass separator. Their Gamow-Teller strength are surveyed in their present experimental status, together with related results from the ISOLDE (CERN) and ISOCELE (Orsay) separators, and are compared with predictions from different nuclear models. The strength of the 0 + → 1 + Gamow-Teller transitions is compiled in tables and graphs. (orig.)

  13. Emittance Growth during Bunch Compression in the CTF-II

    Energy Technology Data Exchange (ETDEWEB)

    Raubenheimer, Tor O

    1999-02-26

    Measurements of the beam emittance during bunch compression in the CLIC Test Facility (CTF-II) are described. The measurements were made with different beam charges and different energy correlations versus the bunch compressor settings which were varied from no compression through the point of full compression and to over-compression. Significant increases in the beam emittance were observed with the maximum emittance occurring near the point of full (maximal) compression. Finally, evaluation of possible emittance dilution mechanisms indicate that coherent synchrotron radiation was the most likely cause.

  14. Electrohydrodynamic emitters of ion beams

    International Nuclear Information System (INIS)

    Dudnikov, V.G.; Shabalin, A.L.

    1990-01-01

    Physical processes determining generation of ion beams with high emission current density in electrohydrodynamic emitters are considered. Electrohydrodynamic effects developing in ion emission features and kinetics of ion interaction in beams with high density are discussed. Factors determining the size of the emission zone, emission stability at high and low currents, cluster generation, increase of energy spread and decrease of brightness are analyzed. Problems on practical provision of stable EHD emitter functioning are considered. 94 refs.; 8 figs.; 1 tab

  15. Emittance measurements in low energy ion storage rings

    Science.gov (United States)

    Hunt, J. R.; Carli, C.; Resta-López, J.; Welsch, C. P.

    2018-07-01

    The development of the next generation of ultra-low energy antiproton and ion facilities requires precise information about the beam emittance to guarantee optimum performance. In the Extra-Low ENergy Antiproton storage ring (ELENA) the transverse emittances will be measured by scraping. However, this diagnostic measurement faces several challenges: non-zero dispersion, non-Gaussian beam distributions due to effects of the electron cooler and various systematic errors such as closed orbit offsets and inaccurate rms momentum spread estimation. In addition, diffusion processes, such as intra-beam scattering might lead to emittance overestimates. Here, we present algorithms to efficiently address the emittance reconstruction in presence of the above effects, and present simulation results for the case of ELENA.

  16. Improvements in emittance wake field optimization for the SLAC Linear Collider

    CERN Document Server

    Decker, Franz Josef

    2003-01-01

    The transverse emittances in the SLAC Linear Collider can be severely diluted by collective wakefield effects and dispersion. For the 1997/98 SLC/SLD run important changes were implemented in the way the emittance is optimized. Early in the linac, where the energy spread is large due to BNS damping, the emittance growth is dominated by dispersion. In this regime emittance tuning bumps may introduce additional wakefield tails and their use is now avoided. At the end of the linac the energy spread is minimal and the emittance measurement is most sensitive to wakefield emittance dilution. In previous years, the emittances were tuned on wire scanners located near but not at the end of the linac (after about 90% of its length). Simulations show that emittance growth of up to 100% can occur in the remaining 10%. In this run wire scanners at the entrance of the Final Focus, the last place where the emittances can be measured, were used for the optimization. Screens at the end of the linac allow additional real time ...

  17. Field emission characteristics of a small number of carbon fiber emitters

    Directory of Open Access Journals (Sweden)

    Wilkin W. Tang

    2016-09-01

    Full Text Available This paper reports an experiment that studies the emission characteristics of small number of field emitters. The experiment consists of nine carbon fibers in a square configuration. Experimental results show that the emission characteristics depend strongly on the separation between each emitter, providing evidence of the electric field screening effects. Our results indicate that as the separation between the emitters decreases, the emission current for a given voltage also decreases. The authors compare the experimental results to four carbon fiber emitters in a linear and square configurations as well as to two carbon fiber emitters in a paired array. Voltage-current traces show that the turn-on voltage is always larger for the nine carbon fiber emitters as compared to the two and four emitters in linear configurations, and approximately identical to the four emitters in a square configuration. The observations and analysis reported here, based on Fowler-Nordheim field emission theory, suggest the electric field screening effect depends critically on the number of emitters, the separation between them, and their overall geometric configuration.

  18. Neutron Diffraction Studies of a Class A beta-Lactamase Toho-1 E166A/R274N/R276N Triple Mutant

    International Nuclear Information System (INIS)

    Blakeley, Matthew P.; Chen, Yu; Afonine, Pavel

    2010-01-01

    beta-Lactam antibiotics have been used effectively over several decades against many types of bacterial infectious diseases. However, the most common cause of resistance to the beta-lactam antibiotics is the production of beta-lactamase enzymes that inactivate beta-lactams by rapidly hydrolyzing the amide group of the beta-lactam ring. Specifically, the class A extended-spectrum beta-lactamases (ESBLs) and inhibitor-resistant enzymes arose that were capable of hydrolyzing penicillins and the expanded-spectrum cephalosporins and monobactams in resistant bacteria, which lead to treatment problems in many clinical settings. A more complete understanding of the mechanism of catalysis of these ESBL enzymes will impact current antibiotic drug discovery efforts. Here, we describe the neutron structure of the class A, CTX-M-type ESBL Toho-1 E166A/R274N/R276N triple mutant in its apo form, which is the first reported neutron structure of a beta-lactamase enzyme. This neutron structure clearly reveals the active-site protonation states and hydrogen-bonding network of the apo Toho-1 ESBL prior to substrate binding and subsequent acylation. The protonation states of the active-site residues Ser70, Lys73, Ser130, and Lys234 in this neutron structure are consistent with the prediction of a proton transfer pathway from Lys73 to Ser130 that is likely dependent on the conformation of Lys73, which has been hypothesized to be coupled to the protonation state of Glu166 during the acylation reaction. Thus, this neutron structure is in agreement with a proposed mechanism for acylation that identifies Glu166 as the general base for catalysis.

  19. Emittance calculations for the Stanford Linear Collider injector

    International Nuclear Information System (INIS)

    Sheppard, J.C.; Clendenin, J.E.; Helm, R.H.; Lee, M.J.; Miller, R.H.; Blocker, C.A.

    1983-03-01

    A series of measurements have been performed to determine the emittance of the high intensity, single bunch beam that is to be injected into the Stanford Linear Collider. On-line computer programs were used to control the Linac for the purpose of data acquisition and to fit the data to a model in order to deduce the beam emittance. This paper will describe the method of emittance calculation and present some of the measurement results

  20. Beam emittance measurement from CERN thermionic guns

    International Nuclear Information System (INIS)

    Kester, O.; Rao, R.; Rinolfi, L.

    1992-01-01

    In the LEP Injector Linacs (LIL) a thermionic gun provides electron beams with different peak intensities at an energy of 80 keV. The beam emittances were estimated from the EGUN programme. Since the gun is of triode type, the main contribution to the emittance comes from the grid. The simulation programme does not model the real geometry by assuming a cylindrical symmetry, while the grid does not have such symmetry. A Gun Test Facility (GTF), allowing emittance measurements, based on the 3-gradients-method was installed. The experimental results are presented. (author) 6 refs.; 6 figs

  1. Multi-dimensional beam emittance and β-functions

    International Nuclear Information System (INIS)

    Buon, J.

    1993-05-01

    The concept of r.m.s. emittance is extended to the case of several degrees of freedom that are coupled. That multi-dimensional emittance is lower than the product of the emittances attached to each degree of freedom, but is conserved in a linear motion. An envelope-hyperellipsoid is introduced to define the β-functions of the beam envelope. On the contrary of an one-degree of freedom motion, it is emphasized that these envelope functions differ from the amplitude functions of the normal modes of motion as a result of the difference between the Liouville and Lagrange invariants. (author) 4 refs

  2. Design of fast extraction system for the KEK proton synchrotron

    International Nuclear Information System (INIS)

    McCarthy, J.D.; Kimura, Yoshitaka.

    1975-03-01

    A fast beam extraction system is designed for the KEK 12 GeV Proton Synchrotron. The extraction is performed by the multi-turn beam shaving method in which hyper thin electrostatic septum inflectors are used as shaving elements. The beam loss and the emittance of the extracted beam are analyzed numerically as a function of thickness of the electrostatic septum wires. Specifications of the extraction elements, electrostatic septa, fast and slow bumps, and septum magnets, are given for the configuration of the designed system. (auth.)

  3. Beam phase space and emittance

    International Nuclear Information System (INIS)

    Buon, J.

    1992-02-01

    The classical and elementary results for canonical phase space, the Liouville theorem and the beam emittance are reviewed. Then, the importance of phase portraits to obtain a geometrical description of motion is emphasized, with examples in accelerator physics. Finally, a statistical point of view is used to define beam emittance, to study its law of approximate conservation, with three particular examples, and to introduce a beam envelope-ellipse and the β-function, emphasing the statistical features of its properties. (author) 14 refs.; 11 figs

  4. Combustion powered thermophotovoltaic emitter system

    Energy Technology Data Exchange (ETDEWEB)

    McHenry, R.S. [Naval Academy, Annapolis, MD (United States). Naval Architecture, Ocean and Marine Engineering

    1995-07-01

    The US Naval Academy (USNA) has recently completed an engineering design project for a high temperature thermophotovoltaic (TPV) photon emitter. The final apparatus was to be portable, completely self contained, and was to incorporate cycle efficiency optimization such as exhaust stream recuperation. Through computer modeling and prototype experimentation, a methane fueled emitter system was designed from structural ceramic materials to fulfill the high temperature requirements necessary for high system efficiency. This paper outlines the engineering design process, discusses obstacles and solutions encountered, and presents the final design.

  5. Beam optics on the Melbourne proton microprobe

    International Nuclear Information System (INIS)

    Jamieson, D.N.; Colman, R.A.; Allan, G.L.; Legge, G.J.F.

    1985-01-01

    This review paper summarises results of ion optics development work conducted on the Melbourne Proton Microprobe and the associated Pelletron accelerator. The properties of a field ionization ion source have been investigated with the aim of replacing the existing R.F. ion source in the accelerator in order to obtain a brighter beam for the microprobe. The electrostatic emitter lens in the terminal of the accelerator has also been investigated with the aim of improving the focus of the accelerated beam. Finally, the aberrations of the probe forming lens system have been studied and it is shown how some of these may be corrected with an octupole lens

  6. Coupling single emitters to quantum plasmonic circuits

    DEFF Research Database (Denmark)

    Huck, Alexander; Andersen, Ulrik Lund

    2016-01-01

    In recent years, the controlled coupling of single-photon emitters to propagating surface plasmons has been intensely studied, which is fueled by the prospect of a giant photonic nonlinearity on a nanoscaled platform. In this article, we will review the recent progress on coupling single emitters...

  7. Structure-activity relationships of N-beta-phenylpropionyl-L-tyrosine and its derivatives on the inhibition of an identifiable giant neurone of an African giant snail (Achatina fulica Férussac).

    Science.gov (United States)

    Ariyoshi, Y.; Takeuchi, H.

    1982-01-01

    1 Inhibitory effects of N-beta-phenylpropionyl-L-tyrosine, N-beta-phenylpropionyl-L-tryptophan and their derivatives on an identifiable giant neurone, TAN (tonically autoactive neurone) of an African giant snail (Achatina fulica Férussac) were examined in an attempt to elucidate which structural features are necessary to produce the effect. 2 Of the compounds examined, N-beta-cyclohexylpropionyl-L-tyrosine showed the strongest effect. Its critical concentration (c.c.) was 3 X 10(-8)-10(-7)M, about ten times lower than that of N-beta-phenylpropionyl-L-tyrosine (c.c., 3 X 10(-7)-10(-6)M). N-beta-cyclohexylpropionyl-L-tryptophan (c.c., 10(-6)M) had an effect almost similar to that of N-beta-phenylpropionyl-L-tryptophan (c.c., 10(-6)M). 3 N-beta-Phenylpropionyl-N-methyl-L-tyrosine had no effect at a high concentration. 4 Effects of N-beta-phenylpropionyl-L-tyrosine amide (c.c., 3 X 10(-7)-10(-6)M) and N-beta-phenylpropionyl-L-tryptophan amide (c.c., 10(-6)M) were very similar to those of N-beta-phenylpropionyl-L-tyrosine and N-beta-phenylpropionyl-L-tryptophan respectively. 5 N-beta-Phenylpropionyl-p-amino-L-phenylalanine (c.c., 3 X 10(-5)-10(-4)M) and N-beta-phenylpropionyl-p-chloro-L-phenylalanine (c.c., 10(-4)M) had only a weak effect. 6 It is proposed that the structural features producing the effect are as follows: the active compound has a phenyl or a cyclohexyl group (hydrophobic binding group), after a suitable distance a peptide bond (proton donor and proton acceptor), adjacently a carbonyl group (proton acceptor), and a phenolic hydroxyl or an indolyl imino group (proton donor) in the molecule. PMID:7150871

  8. Implantation of β-emitters on biomedical implants: 32 P isotropic ion implantation using a coaxial plasma reactor

    International Nuclear Information System (INIS)

    Fortin, M.A.; Paynter, R.W.; Sarkissian, A.; Stansfield, B.L.; Terreault, B.; Dufresne, V.

    2003-01-01

    The development of endovascular brachytherapy and the treatment of certain types of cancers (liver, lung, prostate) often require the use of beta-emitters, sometimes in the form of radioisotope-implanted devices. Among the most commonly used isotopes figures 32 P, a pure beta-emitter (maximum energy: 1.7 MeV), of which the path in biological tissues is of a few cm, restricting the impact of electron bombardment to the immediate environment of the implant. Several techniques and processes have been tried to elaborate surfaces and devices showing strongly bonded, or implanted 32 P. Anodizing, vapor phase deposition, grafting of oligonucleotides, as well as ion implantation processes have been investigated by several research groups as methods to implant beta-radioisotopes into surfaces. A coaxial plasma reactor was developed at INRS to implant radioisotopes into cylindrical metallic objects, such as coronary stents commonly used in angioplasty procedures. The dispersion of 32 P atoms on the interior surfaces of the chamber can be investigated using radiographs, contributing to image the plasma ion transport mechanisms that guide the efficiency of the implantation procedure. The amount of radioactivity on the wall liner, on the internal components, and on the biomedical implants are quantified using a surface barrier detector. A comparative study establishes a relationship between the gray scale of the radiographs, and dose measurements. A program was developed to convert the digitized images into maps showing surface dose density in mCi/cm 2 . An integration process allows the quantification of the doses on the walls and components of the reactor. Finally, the resulting integral of the 32 P dose is correlated to the initial amount of radioactivity inserted inside the implanter before the dismantling procedure. This method could be introduced as a fast and reliable way to test, qualify and assess the amount of radioactivity present on the as-produced implants

  9. Purely Organic Thermally Activated Delayed Fluorescence Materials for Organic Light-Emitting Diodes.

    Science.gov (United States)

    Wong, Michael Y; Zysman-Colman, Eli

    2017-06-01

    The design of thermally activated delayed fluorescence (TADF) materials both as emitters and as hosts is an exploding area of research. The replacement of phosphorescent metal complexes with inexpensive organic compounds in electroluminescent (EL) devices that demonstrate comparable performance metrics is paradigm shifting, as these new materials offer the possibility of developing low-cost lighting and displays. Here, a comprehensive review of TADF materials is presented, with a focus on linking their optoelectronic behavior with the performance of the organic light-emitting diode (OLED) and related EL devices. TADF emitters are cross-compared within specific color ranges, with a focus on blue, green-yellow, orange-red, and white OLEDs. Organic small-molecule, dendrimer, polymer, and exciplex emitters are all discussed within this review, as is their use as host materials. Correlations are provided between the structure of the TADF materials and their optoelectronic properties. The success of TADF materials has ushered in the next generation of OLEDs. © 2017 The Authors. Published by WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Theory and measurements of emittance preservation in plasma wakefield acceleration

    Energy Technology Data Exchange (ETDEWEB)

    Frederico, Joel

    2016-12-01

    In this dissertation, we examine the preservation and measurement of emittance in the plasma wakefield acceleration blowout regime. Plasma wakefield acceleration (PWFA) is a revolutionary approach to accelerating charged particles that has been demonstrated to have the potential for gradients orders of magnitude greater than traditional approaches. The application of PWFA to the design of a linear collider will make new high energy physics research possible, but the design parameters must first be shown to be competitive with traditional methods. Emittance preservation is necessary in the design of a linear collider in order to maximize luminosity. We examine the conditions necessary for circular symmetry in the PWFA blowout regime, and demonstrate that current proposals meet these bounds. We also present an application of beam lamentation which describes the process of beam parameter and emittance matching. We show that the emittance growth saturates as a consequence of energy spread in the beam. The initial beam parameters determine the amount of emittance growth, while the contribution of energy spread is negligible. We also present a model for ion motion in the presence of a beam that is much more dense than the plasma. By combining the model of ion motion and emittance growth, we find the emittance growth due to ion motion is minimal in the case of marginal ion motion. In addition, we present a simulation that validates the ion motion model, which is under further development to examine emittance growth of both marginal and pronounced ion motion. Finally, we present a proof-of-concept of an emittance measurement which may enable the analysis of emittance preservation in future PWFA experiments.

  11. A system for monitoring the radiation effects of a proton linear accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Skorkin, V. M., E-mail: skorkin@inr.ru; Belyanski, K. L.; Skorkin, A. V. [Russian Academy of Sciences, Institute for Nuclear Research (Russian Federation)

    2016-12-15

    The system for real-time monitoring of radioactivity of a high-current proton linear accelerator detects secondary neutron emission from proton beam losses in transport channels and measures the activity of radionuclides in gas and aerosol emissions and the radiation background in the environment affected by a linear accelerator. The data provided by gamma, beta, and neutron detectors are transferred over a computer network to the central server. The system allows one to monitor proton beam losses, the activity of gas and aerosol emissions, and the radiation emission level of a linear accelerator in operation.

  12. An interspecies comparison of the biological effects of an inhaled, relatively insoluble beta emitter

    International Nuclear Information System (INIS)

    Griffith, W.C.; Lundgren, D.L.; Hahn, F.F.; Boecker, B.B.; McClellan, R.O.

    1986-01-01

    Mice, rats, Syrian hamsters, and beagle dogs were exposed by inhalation to graded levels of 144 Ce in relatively insoluble forms to demonstrate species similarities and differences regarding patterns of deposition, fate, dosimetry, and dose-response relationships. All animals were serially evaluated to determine lung burdens, held for life-span observation, necropsied at death, and examined histopathologically to characterize the lesions present and to determine the cause of death. The primary malignant lung tumors observed in rodents were predominantly squamous-cell carcinomas and adenocarcinomas, whereas those in dogs at earlier times were primarily hemangiosarcomas and those in dogs that died at later times were pulmonary carcinomas. The relationship between the incidence of lung cancer and absorbed beta dose to the lung differed among species. The results of modeling these data provide a better understanding of how the choice of species can influence the outcome of a life-span study. The data are used to estimate the risk of lung cancer in man from an inhaled beta-emitting radionuclide. 26 refs., 5 figs., 6 tabs

  13. Electromagnetic compatibility of implantable neurostimulators to RFID emitters.

    Science.gov (United States)

    Pantchenko, Oxana S; Seidman, Seth J; Guag, Joshua W; Witters, Donald M; Sponberg, Curt L

    2011-06-09

    The objective of this study is to investigate electromagnetic compatibility (EMC) of implantable neurostimulators with the emissions from radio frequency identification (RFID) emitters. Six active implantable neurostimulators with lead systems were tested for susceptibility to electromagnetic fields generated by 22 RFID emitters. These medical devices have been approved for marketing in the U.S. for a number of intended uses that include: epilepsy, depression, incontinence, Parkinsonian tremor and pain relief. Each RFID emitter had one of the following carrier frequencies: 125 kHz, 134 kHz, 13.56 MHz, 433 MHz, 915 MHz and 2.45 GHz. The test results showed the output of one of the implantable neurostimulators was inhibited by 134 kHz RFID emitter at separation distances of 10 cm or less. The output of the same implantable neurostimulator was also inhibited by another 134 kHz RFID emitter at separation distances of 10 cm or less and also showed inconsistent pulsing rate at a separation distance of 15 cm. Both effects occurred during and lasted through out the duration of the exposure. The clinical significance of the effects was assessed by a clinician at the U.S. Food and Drug Administration. The effects were determined to be clinically significant only if they occurred for extended period of time. There were no observed effects from the other 5 implantable neurostimulators or during exposures from other RFID emitters.

  14. Hanbury–Brown–Twiss measurements at large rapidity separations, or can we measure the proton radius in p-A collisions?

    Energy Technology Data Exchange (ETDEWEB)

    Altinoluk, Tolga [Departamento de Fíõsica de Partículas and IGFAE, Universidade de Santiago de Compostela, 15706 Santiago de Compostela, Galicia-Spain (Spain); Armesto, Néstor, E-mail: nestor.armesto@usc.es [Departamento de Fíõsica de Partículas and IGFAE, Universidade de Santiago de Compostela, 15706 Santiago de Compostela, Galicia-Spain (Spain); Beuf, Guillaume [Department of Physics, Ben-Gurion University of the Negev, Beer Sheva 84105 (Israel); Kovner, Alex [Physics Department, University of Connecticut, 2152 Hillside Road, Storrs, CT 06269-3046 (United States); Lublinsky, Michael [Department of Physics, Ben-Gurion University of the Negev, Beer Sheva 84105 (Israel)

    2016-01-10

    We point out that current calculations of inclusive two-particle correlations in p-A collisions based on the Color Glass Condensate approach exhibit a contribution from Hanbury–Brown–Twiss correlations. These HBT correlations are quite distinct from the standard ones, in that they are apparent for particles widely separated in rapidity. The transverse size of the emitter which is reflected in these correlations is the gluonic size of the proton. This raises an interesting possibility of measuring the proton size directly by the HBT effect of particle pairs produced in p-A collisions.

  15. Study and design of a very high spatial resolution beta imaging system

    International Nuclear Information System (INIS)

    Donnard, J.

    2008-01-01

    The b autoradiography is a widely used technique in pharmacology or biological fields. It is able to locate in two dimensions molecules labeled with beta emitters. The development of a gaseous detector incorporating micro-mesh called PIM in the Subatech laboratory leads to the construction of a very high spatial resolution apparatus dedicated to b imaging. This device is devoted to small analysis surface of a half microscope slide in particular of 3 H or 14 C and the measured spatial resolution is 20 μm FWHM. The recent development of a new reconstruction method allows enlarging the field of investigation to high energy beta emitters such as 131 I, 18 F or 46 Sc. A new device with a large active area of 18*18 cm 2 has been built with a user friendly design. This allows to image simultaneously 10 microscope slides. Thanks to a multi-modality solution, it retains the good characteristics of spatial resolution obtained previously on a small surface. Moreover, different kinds of samples, like microscope slides or scotches can be analysed. The simulation and experimentation work achieved during this thesis led to an optimal disposition of the inner structure of the detector. These results and characterization show that the PIM structure has to be considered for a next generation of b-Imager. (author)

  16. Two-nucleon emitters within a pseudostate method: The case of 6Be and 16Be

    Science.gov (United States)

    Casal, J.

    2018-03-01

    Background: Since the first experimental observation, two-nucleon radioactivity has gained renewed attention since the early 2000s. The 6Be system is the lightest two-proton ground-state emitter, while 16Be was recently proposed to be the first two-neutron ground-state emitter ever observed. A proper understanding of their properties and decay modes requires a reasonable description of the three-body continuum. Purpose: Study the ground-state properties of 6Be and 16Be within a general three-body model and investigate their nucleon-nucleon correlations in the continuum. Method: The pseudostate (PS) method in hyperspherical coordinates, using the analytical transformed harmonic oscillator (THO) basis for three-body systems, is used to construct the 6Be and 16Be ground-state wave functions. These resonances are approximated as a stable PS around the known two-nucleon separation energy. Effective core-N potentials, constrained by the available experimental information on the binary subsystems 5Li and 15Be, are employed in the calculations. Results: The ground state of 16Be is found to present a strong dineutron configuration, with the valence neutrons occupying mostly an l =2 state relative to the core. The results are consistent with previous R -matrix calculations for the actual continuum. The case of 6Be shows a clear symmetry with respect to its mirror partner, the two-neutron halo 6He: The diproton configuration is dominant, and the valence protons occupy an l =1 orbit. Conclusions: The PS method is found to be a suitable tool in describing the properties of unbound core+N +N ground states. For both 16Be and 6Be, the results are consistent with previous theoretical studies and confirm the dominant dinucleon configuration. This favors the picture of a correlated two-nucleon emission.

  17. Srna - Monte Carlo codes for proton transport simulation in combined and voxelized geometries

    Directory of Open Access Journals (Sweden)

    Ilić Radovan D.

    2002-01-01

    Full Text Available This paper describes new Monte Carlo codes for proton transport simulations in complex geometrical forms and in materials of different composition. The SRNA codes were developed for three dimensional (3D dose distribution calculation in proton therapy and dosimetry. The model of these codes is based on the theory of proton multiple scattering and a simple model of compound nucleus decay. The developed package consists of two codes: SRNA-2KG and SRNA-VOX. The first code simulates proton transport in combined geometry that can be described by planes and second order surfaces. The second one uses the voxelized geometry of material zones and is specifically adopted for the application of patient computer tomography data. Transition probabilities for both codes are given by the SRNADAT program. In this paper, we will present the models and algorithms of our programs, as well as the results of the numerical experiments we have carried out applying them, along with the results of proton transport simulation obtained through the PETRA and GEANT programs. The simulation of the proton beam characterization by means of the Multi-Layer Faraday Cup and spatial distribution of positron emitters obtained by our program indicate the imminent application of Monte Carlo techniques in clinical practice.

  18. Self-powered detectors with thulium emitter

    International Nuclear Information System (INIS)

    Haller, P.; Klar, E.

    1978-01-01

    In addition to fission chambers, prompt-indicating self-powered (SPN) detectors are used for measuring the neutron flux density in the core of power reactors. Although current SPN detectors with a cobalt emitter give satisfactora results, detectors with other emitter materials have been analyzed and tested. The author describes the properties and decay pattern of the nuclide thulium and presents the results of measurements made while testing thulium detectors. (orig.) [de

  19. Localization of Narrowband Single Photon Emitters in Nanodiamonds.

    Science.gov (United States)

    Bray, Kerem; Sandstrom, Russell; Elbadawi, Christopher; Fischer, Martin; Schreck, Matthias; Shimoni, Olga; Lobo, Charlene; Toth, Milos; Aharonovich, Igor

    2016-03-23

    Diamond nanocrystals that host room temperature narrowband single photon emitters are highly sought after for applications in nanophotonics and bioimaging. However, current understanding of the origin of these emitters is extremely limited. In this work, we demonstrate that the narrowband emitters are point defects localized at extended morphological defects in individual nanodiamonds. In particular, we show that nanocrystals with defects such as twin boundaries and secondary nucleation sites exhibit narrowband emission that is absent from pristine individual nanocrystals grown under the same conditions. Critically, we prove that the narrowband emission lines vanish when extended defects are removed deterministically using highly localized electron beam induced etching. Our results enhance the current understanding of single photon emitters in diamond and are directly relevant to fabrication of novel quantum optics devices and sensors.

  20. Innovative energy efficient low-voltage electron beam emitters

    International Nuclear Information System (INIS)

    Felis, Kenneth P.; Avnery, Tovi; Berejka, Anthony J.

    2002-01-01

    Advanced electron beams (AEB) has developed a modular, low voltage (80-125 keV), high beam current (up to 40 ma), electron emitter with typically 25 cm of beam width, that is housed in an evacuated, returnable chamber that is easy to plug in and connect. The latest in nanofabrication enables AEB to use an ultra-thin beam window. The power supply for AEB's emitter is based on solid-state electronics. This combination of features results in a remarkable electrical efficiency. AEB's electron emitter relies on a touch screen, computer control system. With 80 μm of unit density beam penetration, AEB's electron emitter has gained market acceptance in the curing of opaque, pigmented inks and coatings used on flexible substrates, metals and fiber composites and in the curing of adhesives in foil based laminates

  1. Innovative energy efficient low-voltage electron beam emitters

    Science.gov (United States)

    Felis, Kenneth P.; Avnery, Tovi; Berejka, Anthony J.

    2002-03-01

    Advanced electron beams (AEB) has developed a modular, low voltage (80-125 keV), high beam current (up to 40 ma), electron emitter with typically 25 cm of beam width, that is housed in an evacuated, returnable chamber that is easy to plug in and connect. The latest in nanofabrication enables AEB to use an ultra-thin beam window. The power supply for AEB's emitter is based on solid-state electronics. This combination of features results in a remarkable electrical efficiency. AEB's electron emitter relies on a touch screen, computer control system. With 80 μm of unit density beam penetration, AEB's electron emitter has gained market acceptance in the curing of opaque, pigmented inks and coatings used on flexible substrates, metals and fiber composites and in the curing of adhesives in foil based laminates.

  2. Active interrogation using energetic protons

    International Nuclear Information System (INIS)

    Morris, Christopher L.; Chung, Kiwhan; Greene, Steven J.; Hogan, Gary E.; Makela, Mark; Mariam, Fesseha; Milner, Edward C.; Murray, Matthew; Saunders, Alexander; Spaulding, Randy; Wang, Zhehui; Waters, Laurie; Wysocki, Frederick

    2010-01-01

    Energetic proton beams provide an attractive alternative when compared to electromagnetic and neutron beams for active interrogation of nuclear threats because they have large fission cross sections, long mean free paths and high penetration, and they can be manipulated with magnetic optics. We have measured time-dependent cross sections and neutron yields for delayed neutrons and gamma rays using 800 MeV and 4 GeV proton beams with a set of bare and shielded targets. The results show significant signals from both unshielded and shielded nuclear materials. Measurements of neutron energies yield suggest a signature unique to fissile material. Results are presented in this paper.

  3. Monitoring of gross alpha, gross beta and tritium activities in portuguese drinking waters

    International Nuclear Information System (INIS)

    Lopes, I.; Madruga, M.J.; Ferrador, G.O.; Sequeira, M.M.; Oliveira, E.J.; Gomes, A.R.; Rodrigues, F.D.; Carvalho, F.P.

    2006-01-01

    The gross beta and tritium activities in the forty Portuguese drinking waters analyzed using the ISO standard methods (Portuguese Guidelines) are below the guidance levels proposed in the Portuguese Drinking Water Quality Guidelines. In what concerns the gross alpha activity only 18% exceeded the recommended level. In general, it can be concluded that the ingestion of these drinking waters does not create a radiological hazard to the human consumption, however, more detailed analyses will be necessary mainly the determinations of the individual alpha emitters radionuclide concentrations. The minimum gross alpha and gross beta detectable activities by L.S.C. methodology are higher than for the proportional counting technique (ISO method). Higher concentration factors will be needed to reach lower required detection limits. (authors)

  4. Evaluations of carbon nanotube field emitters for electron microscopy

    Science.gov (United States)

    Nakahara, Hitoshi; Kusano, Yoshikazu; Kono, Takumi; Saito, Yahachi

    2009-11-01

    Brightness of carbon nanotube (CNT) emitters was already reported elsewhere. However, brightness of electron emitter is affected by a virtual source size of the emitter, which strongly depends on electron optical configuration around the emitter. In this work, I- V characteristics and brightness of a CNT emitter are measured under a practical field emission electron gun (e-gun) configuration to investigate availability of CNT for electron microscopy. As a result, it is obtained that an emission area of MWNT is smaller than its tip surface area, and the emission area corresponds to a five-membered-ring with 2nd nearest six-membered-rings on the MWNT cap surface. Reduced brightness of MWNT is measured as at least 2.6×109 A/m 2 sr V. It is concluded that even a thick MWNT has enough brightness under a practical e-gun electrode configuration and suitable for electron microscopy.

  5. Very bright, near-infrared single photon emitters in diamond

    Directory of Open Access Journals (Sweden)

    D. W. M. Lau

    2013-09-01

    Full Text Available We demonstrate activation of bright diamond single photon emitters in the near infrared range by thermal annealing alone, i.e., without ion implantation. The activation is crucially dependent on the annealing ambient. The activation of the single photon emitters is only observed when the sample is annealed in forming gas (4% H2 in Ar above temperatures of 1000 °C. By contrast, no emitters are activated by annealing in vacuum, oxygen, argon or deuterium. The emitters activated by annealing in forming gas exhibit very bright emission in the 730-760 nm wavelength range and have linewidths of ∼1.5-2.5 nm at room temperature.

  6. Characterization of commercial proton exchange membrane materials after exposure to beta and gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Thomson, S.N.; Carson, R.; Muirhead, C.; Li, H.; Castillo, I.; Boniface, H.; Suppiah, S. [Canadian Nuclear Laboratories, Chalk River, ON (Canada); Ratnayake, A.; Robinson, J. [Tyne Engineering Inc., Burlington, ON (Canada)

    2015-03-15

    Proton Exchange Membrane (PEM) type electrolysis cells have a potential use for tritium removal and heavy water upgrading. AECL is currently exposing various commercial PEM materials to both gamma (Cobalt-60 source) and beta (tritiated water) radiation to study the effects of radiation on these materials. This paper summarizes the testing methods and results that have been collected to date. The PEM materials that are or have been exposed to radiation are: Nafion 112, 212, 117 and 1110. Membrane characterization pre- and post- exposure consists of non-destructive inspection (FTIR, SEM/XPS), mechanical (tensile strength, percentage elongation, and modulus), electrical (resistance), or chemical (ion-exchange capacity - IEC). It has appeared that the best characterization techniques to compare exposed versus unexposed membranes were IEC, ultimate tensile strength and percent elongation. These testing techniques are easy and cheap to perform. The non-destructive tests, such as SEM and FTIR did not provide particularly useful information on radiation-induced degradation. Where changes in material properties were measured after radiation exposure, they would be expected to result in poorer cell performance. However, for modest γ-radiation exposure, all membranes showed a slight decrease in cell voltage (better performance). In contrast, the one β-radiation exposed membrane did show the expected increase in cell voltage. The counterintuitive trend for γ-radiation exposed membranes is not yet understood. Based on these preliminary results, it appears that γ- and β-radiation exposures have different effects.

  7. Beta-endorphin and alpha-n-acetyl beta-endorphin; synthesis, conformation and binding parameter

    Energy Technology Data Exchange (ETDEWEB)

    Lovegren, E.S.

    1986-01-01

    Beta-endorphin (EP) is a 31-residue opioid peptide found in many tissues, including the pituitary, brain and reproductive tract. Alpha-amino-acetyl beta-endorphin (AcEP) was characterized spectroscopically by proton nuclear magnetic resonance (NMR) and circular dichroism in deuterated water and trifluoroethanol (TFE). Both EP and AcEP bind to neuroblastoma N2a cells. This binding was not mediated through opiate receptors, and both peptides seemed to bind at common sites. Ovarian immunoreactive-EP levels were determined for immature and mature rates. These levels were found to be responsive to exogenous gonadotropin treatment in immature animals. A large percentage of the immunoreactive-EP is present in follicular fluid, and most of the endorphin-like peptides were acetylated, as measured by radioimmunoassay. Chromatogaphic analysis suggested at least three EP-like species: EP, a carboxy-terminally cleaved and an amino-terminally acetylated EP.

  8. Measurement of emittance of metal interface in molten salt

    International Nuclear Information System (INIS)

    Araki, N.; Makino, A.; Nakamura, Y.

    1995-01-01

    A new technique for measuring the total normal emittance of a metal in a semi-transparent liquid has been proposed and this technique has been applied to measure the emittance of stainless steel (SUS304), nickel, and gold in molten potassium nitrate KNO 3 . These emittance data are indispensable to analyzing the radiative heat transfer between a metal and a semitransparent liquid, such as a molten salt

  9. Atmospheric deposition of long-lived Beta radionuclides over the territory of Bulgaria during the last decades

    Energy Technology Data Exchange (ETDEWEB)

    Veleva, B. [National Institute of Meteorology and Hydrology, Bulgarian Academy of Sciences, Sofia (Bulgaria)

    2013-07-01

    The sources of atmospheric radioactivity are discussed and compared. Radon isotopes and their daughters' dominate the natural background of beta activity in the surface air. The man-made radionuclides, much of them beta emitters, started to contaminate regionally and globally the environment after 1940's due to the atmospheric nuclear bomb tests. Additional significant sources of technogenic radionuclides in the atmosphere were nuclear accidents with pronounced examples of Chernobyl and Fukushima. The Bulgarian network for atmospheric radioactivity monitoring has been developing since 1959 in the frame of the state Hydro-meteorological service, now National Institute of Meteorology and Hydrology. It includes daily measurements of aerosol beta activity and deposition immediately and 120h after the sampling. The time and space variations of deposited beta activity, based on long term data records are presented and impact assessment of the different sources is given. The role of precipitation in deposition of radionuclides is evaluated. (author)

  10. Role of quenching on alpha/beta separation in liquid scintillation counting for several high capacity cocktails

    International Nuclear Information System (INIS)

    Pujol, L.; Sanchez-Cabeza, J.-A.

    1997-01-01

    The optimization of alpha/beta separation in liquid scintillation using pulse shape analysis is convenient for the simultaneous determination of alpha and beta emitters in natural water and other samples. In this work, alpha/beta separation was studied for different scintillant/vial combinations and it was observed that both the optimum pulse shape discrimination level and the total interference value (that is, the summed relative interference between alpha and beta spectra) were dependent on the sample quenching and independent of the scintillant/vial combination. These results provide a simple method for modifying the counting configuration, such as a change in the cocktail, vial or sample characteristics, without the need to perform exhaustive parameter optimizations. Also, it was observed that, for our counting conditions, the combination of Ultima Gold AB scintillation cocktail with Zinsser low diffusion vials presented the lowest total interference, namely 0.94 ± 0.28%, which is insignificant for the counting of environmental samples. (Author)

  11. Boundary conditions on the plasma emitter surface in the presence of a particle counter flow: I. Ion emitter

    Energy Technology Data Exchange (ETDEWEB)

    Astrelin, V. T., E-mail: V.T.Astrelin@inp.nsk.su; Kotelnikov, I. A. [Russian Academy of Sciences, Budker Institute of Nuclear Physics, Siberian Branch (Russian Federation)

    2017-02-15

    Emission of positively charged ions from a plasma emitter irradiated by a counterpropagating electron beam is studied theoretically. A bipolar diode with a plasma emitter in which the ion temperature is lower than the electron temperature and the counter electron flow is extracted from the ion collector is calculated in the one-dimensional model. An analog of Bohm’s criterion for ion emission in the presence of a counterpropagating electron beam is derived. The limiting density of the counterpropagating beam in a bipolar diode operating in the space-charge-limited-emission regime is calculated. The full set of boundary conditions on the plasma emitter surface that are required for operation of the high-current optics module in numerical codes used to simulate charged particle sources is formulated.

  12. Delayed photoneutrons of the of the Dalat Nuclear Research Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Huy, Ngo Quang [Centre for Nuclear Technique Application, Ho Chi Minh City (Viet Nam); Thong, Ha Van; Long, Vu Hai; Khang, Ngo Phu; Dien, Nguyen Nhi; Lam, Pham Van; Phuong, Huynh Dong; Vien, Luong Ba; Vinh, Le Vinh [Nuclear Research Inst., Da Lat (Viet Nam)

    1994-10-01

    Time spectrum of delayed neutrons of the Dalat nuclear research reactor is measured and analyzed. It corresponds to a shut-down neutron fluxes of about 10{sup 5}/10{sup 8} n/cm{sup 2}/sec after 100 hours continuous reactor operation at steady power level of 500 kW. Data processing of experimental time neutron spectrum gives 16 exponents, of which 10, resulting from photoneutrons due to ({gamma},n) reactions on beryllium used inside the reactor core, are obtained by using successive exponential stripping fitting method. For the Dalat reactor, the effective delayed photoneutron fraction relative to the total effective delayed neutron fraction is {beta}{sup B}e{sub eff}=0.49%{beta}{sub eff} for a beryllium weight relative to U{sup 235} fuel of m{sub B}e/m{sub U} = 8.5. This result is acceptable in comparison to those obtained for other Be-U{sup 235} media. (author). 5 refs., 2 figs., 4 tabs.

  13. Electromagnetic compatibility of implantable neurostimulators to RFID emitters

    Directory of Open Access Journals (Sweden)

    Guag Joshua W

    2011-06-01

    Full Text Available Abstract Background The objective of this study is to investigate electromagnetic compatibility (EMC of implantable neurostimulators with the emissions from radio frequency identification (RFID emitters. Methods Six active implantable neurostimulators with lead systems were tested for susceptibility to electromagnetic fields generated by 22 RFID emitters. These medical devices have been approved for marketing in the U.S. for a number of intended uses that include: epilepsy, depression, incontinence, Parkinsonian tremor and pain relief. Each RFID emitter had one of the following carrier frequencies: 125 kHz, 134 kHz, 13.56 MHz, 433 MHz, 915 MHz and 2.45 GHz Results The test results showed the output of one of the implantable neurostimulators was inhibited by 134 kHz RFID emitter at separation distances of 10 cm or less. The output of the same implantable neurostimulator was also inhibited by another 134 kHz RFID emitter at separation distances of 10 cm or less and also showed inconsistent pulsing rate at a separation distance of 15 cm. Both effects occurred during and lasted through out the duration of the exposure. Conclusions The clinical significance of the effects was assessed by a clinician at the U.S. Food and Drug Administration. The effects were determined to be clinically significant only if they occurred for extended period of time. There were no observed effects from the other 5 implantable neurostimulators or during exposures from other RFID emitters.

  14. Emittance growth and tune spectra at PETRA III

    International Nuclear Information System (INIS)

    Wanzenberg, R.

    2011-08-01

    At DESY the PETRA ring has been converted into a synchrotron radiation facility, called PETRA III. 20 damping wigglers have been installed to achieve an emittance of 1 nm. The commissioning with beam started in April 2009 and user runs have been started in 2010. The design current is 100 mA and the bunch to bunch distance is 8 ns for one particular filling pattern with 960 bunches. At a current of about 50 mA a strong vertical emittance increase has been observed. During machine studies it was found that the emittance increase depends strongly on the bunch filling pattern. For the user operation a filling scheme has been found which mitigates the increase of the vertical emittance. In August 2010 PETRA III has been operated without damping wigglers for one week. The vertical emittance growth was not significantly smaller without wigglers. Furthermore tune spectra at PETRA III show characteristic lines which have been observed at other storage rings in the connection with electron clouds. Measurements at PETRA III are presented for different bunch filling patterns and with and without wiggler magnets. (orig.)

  15. Simulation study on beam loss in the alpha bucket regime during SIS-100 proton operation

    Science.gov (United States)

    Sorge, S.

    2018-02-01

    Crossing the transition energy γt in synchrotrons for high intensity proton beams requires well tuned jump schemes and is usually accompanied by longitudinal emittance growth. In order to avoid γt crossing during proton operation in the projected SIS-100 synchrotron special high-γt lattice settings have been developed, in order to keep γt above the beam extraction energy. A further advantage of this scheme is the formation of alpha buckets which naturally lead to short proton bunches, required for the foreseen production and storage of antiprotons for the FAIR facility. Special attention is turned on the imperfections of the superconducting SIS-100 magnets because together with the high-γt lattice settings, they could potentially lead to enhanced beam loss. The aim of the present work is to estimate the beam loss by means of particle tracking simulations.

  16. Formation cross-sections and chromatographic separation of protactinium isotopes formed in proton-irradiated thorium metal

    Energy Technology Data Exchange (ETDEWEB)

    Radchenko, Valery; Engle, Jonathan W.; Wilson, Justin J.; Maassen, Joel R.; Nortier, Meiring F.; Birnbaum, Eva R.; John, Kevin D.; Fassbender, Michael E. [Los Alamos National Laboratory, NM (United States)

    2016-08-01

    Targeted alpha therapy (TAT) is a treatment method of increasing interest to the clinical oncology community that utilizes α-emitting radionuclides conjugated to biomolecules for the selective killing of tumor cells. Proton irradiation of thorium generates a number of α-emitting radionuclides with therapeutic potential for application via TAT. In particular, the radionuclide {sup 230}Pa is formed via the {sup 232}Th(p, 3n) nuclear reaction and partially decays to {sup 230}U, an α emitter which has recently received attention as a possible therapy nuclide. In this study, we estimate production yields for {sup 230}Pa and other Pa isotopes from proton-irradiated thorium based on cross section measurements. We adopt existing methods for the chromatographic separation of protactinium isotopes from proton irradiated thorium matrices to combine and optimize them for effective fission product decontamination.

  17. A polarization-insensitive plasmonic photoconductive terahertz emitter

    KAUST Repository

    Li, Xurong

    2017-11-16

    We present a polarization-insensitive plasmonic photoconductive terahertz emitter that uses a two-dimensional array of nanoscale cross-shaped apertures as the plasmonic contact electrodes. The geometry of the cross-shaped apertures is set to maximize optical pump absorption in close proximity to the contact electrodes. The two-dimensional symmetry of the cross-shaped apertures offers a polarization-insensitive interaction between the plasmonic contact electrodes and optical pump beam. We experimentally demonstrate a polarization-insensitive terahertz radiation from the presented emitter in response to a femtosecond optical pump beam and similar terahertz radiation powers compared to previously demonstrated polarization-sensitive photoconductive emitters with plasmonic contact electrode gratings at the optimum optical pump polarization.

  18. Emittance measurement for high-brightness electron guns

    International Nuclear Information System (INIS)

    Kobayashi, H.; Kurihara, T.; Sato, I.; Asami, A.; Yamazaki, Y.; Otani, S.; Ishizawa, Y.

    1992-01-01

    An emittance measurement system based on a high-precision pepper-pot technique has been developed for electron guns with low emittance of around πmm-mrad. Electron guns with a 1 mmφ cathode, the material of which is impregnated tungsten or single-crystal lanthanum hexaboride (La 1-x Ce x )B 6 , have been developed. The performance has been evaluated by putting stress on cathode roughness, which gives rise to an angular divergence, according to the precise emittance measurement system. A new type of cathode holder, which is a modified version of the so called Vogel type, was developed and the beam uniformity has been improved. (Author) 5 figs., tab., 9 refs

  19. Evaluations of carbon nanotube field emitters for electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Nakahara, Hitoshi, E-mail: nakahara@nagoya-u.jp [Department of Quantum Engineering, Graduate School of Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603 (Japan); Kusano, Yoshikazu; Kono, Takumi; Saito, Yahachi [Department of Quantum Engineering, Graduate School of Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603 (Japan)

    2009-11-30

    Brightness of carbon nanotube (CNT) emitters was already reported elsewhere. However, brightness of electron emitter is affected by a virtual source size of the emitter, which strongly depends on electron optical configuration around the emitter. In this work, I-V characteristics and brightness of a CNT emitter are measured under a practical field emission electron gun (e-gun) configuration to investigate availability of CNT for electron microscopy. As a result, it is obtained that an emission area of MWNT is smaller than its tip surface area, and the emission area corresponds to a five-membered-ring with 2nd nearest six-membered-rings on the MWNT cap surface. Reduced brightness of MWNT is measured as at least 2.6x10{sup 9} A/m{sup 2} sr V. It is concluded that even a thick MWNT has enough brightness under a practical e-gun electrode configuration and suitable for electron microscopy.

  20. Few emitters in a cavity: from cooperative emission to individualization

    International Nuclear Information System (INIS)

    Auffeves, A; Portolan, S; Gerace, D; Drezet, A; Franca Santos, M

    2011-01-01

    We study the temporal correlations of the field emitted by an electromagnetic resonator coupled to a mesoscopic number of two-level emitters that are incoherently pumped by a weak external drive. We solve the master equation of the system for increasing number of emitters and as a function of the cavity quality factor, and we identify three main regimes characterized by well-distinguished statistical properties of the emitted radiation. For small cavity decay rates, the emission events are uncorrelated and the number of photons in the emitted field becomes larger than one, resembling the build-up of a laser field inside the cavity. At intermediate decay rates (as compared with the emitter-cavity coupling) and for a few emitters, the statistics of the emitted radiation is bunched and strikingly dependent on the parity of the number of emitters. The latter property is related to the cooperativity of the emitters mediated by their coupling to the cavity mode, and its connection with steady-state subradiance is discussed. Finally, in the bad cavity regime the typical situation of emission from a collection of individual emitters is recovered. We also analyze how the cooperative behavior evolves as a function of pure dephasing, which allows us to recover the case of a classical source made of an ensemble of independent emitters, similar to what is obtained for a very leaky cavity. State-of-the-art techniques of Q-switch of resonant cavities, allied with the recent capability of tuning single emitters in and out of resonance, suggest this system to be a versatile source of different quantum states of light.

  1. Few emitters in a cavity: from cooperative emission to individualization

    Energy Technology Data Exchange (ETDEWEB)

    Auffeves, A; Portolan, S [CEA/CNRS/UJF Joint Team ' Nanophysics and Semiconductors' , Institut Neel-CNRS, BP 166, 25 Rue des Martyrs, 38042 Grenoble Cedex 9 (France); Gerace, D [Dipartimento di Fisica ' Alessandro Volta' and UdR CNISM, Universita di Pavia, via Bassi 6, 27100 Pavia (Italy); Drezet, A [Institut Neel-CNRS, BP 166, 25 Rue des Martyrs, 38042 Grenoble Cedex 9 (France); Franca Santos, M, E-mail: msantos@fisica.ufmg.br [Departamento de Fisica, Universidade Federal de Minas Gerais, Belo Horizonte, CP 702, 30123-970 (Brazil)

    2011-09-15

    We study the temporal correlations of the field emitted by an electromagnetic resonator coupled to a mesoscopic number of two-level emitters that are incoherently pumped by a weak external drive. We solve the master equation of the system for increasing number of emitters and as a function of the cavity quality factor, and we identify three main regimes characterized by well-distinguished statistical properties of the emitted radiation. For small cavity decay rates, the emission events are uncorrelated and the number of photons in the emitted field becomes larger than one, resembling the build-up of a laser field inside the cavity. At intermediate decay rates (as compared with the emitter-cavity coupling) and for a few emitters, the statistics of the emitted radiation is bunched and strikingly dependent on the parity of the number of emitters. The latter property is related to the cooperativity of the emitters mediated by their coupling to the cavity mode, and its connection with steady-state subradiance is discussed. Finally, in the bad cavity regime the typical situation of emission from a collection of individual emitters is recovered. We also analyze how the cooperative behavior evolves as a function of pure dephasing, which allows us to recover the case of a classical source made of an ensemble of independent emitters, similar to what is obtained for a very leaky cavity. State-of-the-art techniques of Q-switch of resonant cavities, allied with the recent capability of tuning single emitters in and out of resonance, suggest this system to be a versatile source of different quantum states of light.

  2. Emittance formula for slits and pepper-pot measurement

    International Nuclear Information System (INIS)

    Zhang, M.

    1996-10-01

    In this note, a rigid formula for slits and pepper-pot emittance measurement is derived. The derivation is based on the one- dimensional slit measurement setup. A mathematical generalization of the slit emittance formula to the pepper-pot measurement is discussed

  3. MEV Energy Electrostatic Accelerator Ion Beam Emittance Measurement

    OpenAIRE

    I.G. Ignat’ev; M.I. Zakharets; S.V. Kolinko; D.P. Shulha

    2014-01-01

    The testing equipment was designed, manufactured and tried out permitting measurements of total current, current profile and emittance of an ion beam extracted from the ion beam. MeV energy electrostatic accelerator ion H + beam emittance measurement results are presented.

  4. A beta skin dose monitor using an Eberline RO-2 ion chamber

    International Nuclear Information System (INIS)

    Jester, W.A.; Levine, S.H.; Lin, T.J.; Hock, R.

    1994-01-01

    The authors have developed a portable beta skin dose monitor that uses an Eberline RO-2trademark ion chamber. The development was based, in part, upon the previous development of a beta skin dose monitor employing silicon detectors. In this current work, the two entrance windows of the RO-2 were replaced by windows having a total mass thickness of 1.74 mg/cm 2 . A two section source-detector holder was constructed. One section fastens to the RO-2 and holds the detector at the right position to determine the contact skin dose from beta emitters located on surfaces. A second section attaches to the first, and provides fixed counting geometry for radioactive samples such as hot particles. The first section also contains a slide mechanism that allows the placement of absorbers of zero (0), 8.38, and 1000 mg/cm 2 between the detector window and the beta source. The detector response to these absorbers allows for the determination of beta skin dose. The system was modeled using a Monte Carlo beta attenuation code computing the beta skin dose to RO-2 detector response as a function of absorber thickness, average beta energy, source diameter and source position. Using the RO-2 reading from each of the three absorber configurations allows the calculation of beta skin dose and the average beta energy. The results of these calculations were confirmed through the use of three massless radioactive beta sources, traceable to the National Institute of Standards and Technology, and several utility-supplied hot particles having well-established contact skin doses. An extrapolation chamber was also used to confirm the results obtained from this monitor. This system is now use at the Pennsylvania Power and Light (PP and L) Company, the project sponsor. ((orig.))

  5. Alpha-emitters for medical therapy workshop

    International Nuclear Information System (INIS)

    Feinendegen, L.E.; McClure, J.J.

    1996-01-01

    A workshop on ''Alpha-Emitters for Medical Therapy'' was held May 30-31, 1996 in Denver Colorado to identify research goals and potential clinical needs for applying alpha-particle emitters and to provide DOE with sufficient information for future planning. The workshop was attended by 36 participants representing radiooncology, nuclear medicine, immunotherapy, radiobiology, molecular biology, biochemistry, radiopharmaceutical chemistry, dosimetry, and physics. This report provides a summary of the key points and recommendations arrived at during the conference

  6. Alpha-emitters for medical therapy workshop

    Energy Technology Data Exchange (ETDEWEB)

    Feinendegen, L.E.; McClure, J.J.

    1996-12-31

    A workshop on ``Alpha-Emitters for Medical Therapy`` was held May 30-31, 1996 in Denver Colorado to identify research goals and potential clinical needs for applying alpha-particle emitters and to provide DOE with sufficient information for future planning. The workshop was attended by 36 participants representing radiooncology, nuclear medicine, immunotherapy, radiobiology, molecular biology, biochemistry, radiopharmaceutical chemistry, dosimetry, and physics. This report provides a summary of the key points and recommendations arrived at during the conference.

  7. Covariant density functional theory for decay of deformed proton emitters: A self-consistent approach

    Directory of Open Access Journals (Sweden)

    L.S. Ferreira

    2016-02-01

    Full Text Available Proton radioactivity from deformed nuclei is described for the first time by a self-consistent calculation based on covariant relativistic density functionals derived from meson exchange and point coupling models. The calculation provides an important new test to these interactions at the limits of stability, since the mixing of different angular momenta in the single particle wave functions is probed.

  8. Beta-Excited Sources of Electromagnetic Radiation; Sources de rayonnements electromagnetiques excites par des particules beta; Vozbuzhdennye beta-chastitsami istochniki ehlektromagnitnogo izlucheniya; Fuentes de radiacion electromagnetica excitadas por particulas beta

    Energy Technology Data Exchange (ETDEWEB)

    Cameron, J F; Rhodes, J R [Physics Group, Isotope Research Division, (AERE), Wantage Research Laboratory, Wantage, Berks (United Kingdom)

    1962-01-15

    Beta-excited sources of electromagnetic radiation covering the energy region 1-200 keV and suitable for industrial use are described. H{sup 3}, Pm{sup 147}, Kr{sup 85}, Tl{sup 204} and (Sr+Y){sup 90} were chosen as sources of beta particles by the criteria of long half-life, low price, ready availability and high specific activity. The {beta}-excited sources have been designed on the basis of a compromise between practical source construction and the best theoretical efficiency in a given energy region. In their paper, the authors calculate the number of photons produced per beta particle and consider how the results must be corrected for self-absorption of the X-rays. In the calculations account is taken of both bremsstrahlung and characteristic {alpha}-radiation; optimum characteristic X-ray yield is achieved for targets with an atomic number between 40 and 60. ''Sandwich'' targets of 1-2 beta half-value thicknesses are found to give maximum photon-yields in the desired energy region. Al, Ag and Au are suitable from the manufacturing point of view as source coverings. They were also found to give satisfactory bremsstrahlung and X-ray yields and distribution for various energy regions in the range 1-200 keV when correctly combined with the above-mentioned D-emitters. Some energy spectra are given and absorption curves in Al and Fe are shown for the best source-target combinations. The difference between sources constructed of {beta}-emitters sandwiched between target foils and intimate source-target mixtures was found to be small. Tables are given as a guide to the best source to be used for a particular absorber thickness range. (author) [French] Les auteurs decrivent des sources de rayonnements electromagnetiques excites par des particules beta, couvrant une gamme d'energies allant de 1 a 200 keV et convenant aux usages industriels. Comme sources de particules beta on a choisi le tritium, le {sup 147}Pm, le {sup 85}Kr, le {sup 204}Tl et le {sup 90}(Sr+Y), en

  9. High-quality electron beam generation in a proton-driven hollow plasma wakefield accelerator

    Science.gov (United States)

    Li, Y.; Xia, G.; Lotov, K. V.; Sosedkin, A. P.; Hanahoe, K.; Mete-Apsimon, O.

    2017-10-01

    Simulations of proton-driven plasma wakefield accelerators have demonstrated substantially higher accelerating gradients compared to conventional accelerators and the viability of accelerating electrons to the energy frontier in a single plasma stage. However, due to the strong intrinsic transverse fields varying both radially and in time, the witness beam quality is still far from suitable for practical application in future colliders. Here we demonstrate the efficient acceleration of electrons in proton-driven wakefields in a hollow plasma channel. In this regime, the witness bunch is positioned in the region with a strong accelerating field, free from plasma electrons and ions. We show that the electron beam carrying the charge of about 10% of 1 TeV proton driver charge can be accelerated to 0.6 TeV with a preserved normalized emittance in a single channel of 700 m. This high-quality and high-charge beam may pave the way for the development of future plasma-based energy frontier colliders.

  10. The relative effectiveness of inhaled alpha- and beta-emitting radionuclides in producing lung cancer

    International Nuclear Information System (INIS)

    Boecker, B.B.; Hahn, F.F.; Muggenburg, B.A.; Guilmetter, R.A.; Griffith, W.C.; McClellan, R.O.

    1988-01-01

    Proper assessment of a long-term human health risks associated with inhaled radionuclides requires knowledge of dose to critical cells and tissues and relationships between dose and effect for different biological end points. Results from epidemiological studies of exposed human populations provided important information for such assessments. However, because the types of exposures are limited, these results need to be supplemented with more detailed information on dosimetry and biological effects available through studies in laboratory animals and in vitro systems. To provide health risk information for inhaled fission product and actinide aerosols, life-span studies are being conducted using beagle dogs and other species at the Lovelace Inhalation Toxicology Research Institute (ITRI). Results of two life-span studies in dogs involving inhalation of the beta emitter 91 Y in fused aluminosilicate particles or the alpha emitter 239 PuO 2 are reported here

  11. Experimental investigation of thermal emittance components of copper photocathode

    Directory of Open Access Journals (Sweden)

    H. J. Qian

    2012-04-01

    Full Text Available With progress of photoinjector technology, thermal emittance has become the primary limitation of electron beam brightness. Extensive efforts have been devoted to study thermal emittance, but experiment results differ between research groups and few can be well interpreted. Besides the ambiguity of photoemission mechanism, variations of cathode surface conditions during cathode preparation, such as work function, field enhancement factor, and surface roughness, will cause thermal emittance differences. In this paper, we report an experimental study of electric field dependence of copper cathode quantum efficiency (QE and thermal emittance in a radio frequency (rf gun, through which in situ cathode surface parameters and thermal emittance contributions from photon energy, Schottky effect, and surface roughness are extracted. It is found the QE of a copper cathode illuminated by a 266 nm UV laser increased substantially to 1.5×10^{-4} after cathode cleaning during rf conditioning, and a copper work function of 4.16 eV, which is much lower than nominal value (4.65 eV, was measured. Experimental results also show a thermal emittance growth as much as 0.92  mm mrad/mm at 50  MV/m due to the cathode surface roughness effect, which is consistent with cathode surface morphology measurements.

  12. Design for a practical, low-emittance damping ring

    International Nuclear Information System (INIS)

    Krejcik, P.

    1988-01-01

    The luminosity requirements for future high-energy linear colliders calls for very low emittances in the two beams. These low emittances can be achieved with damping rings, but, in order to reach the design goal of a factor 10 improvement over present day machines, great care must be taken in their design. This paper emphasizes the need to address simultaneously all of the factors which limit the operational emittance in the ring. Particularly since in standard designs there is a conflict between different design parameters which makes it difficult to extrapolate such designs to very low emittances. The approach chosen here is to resolve such conflicts by separating their design solutions. Wigglers are used predominantly in zero-dispersion regions to achieve the desired damping rate, whereas in the arcs high dispersion insertions are made in regions of zero curvature to allow for easier chromaticity control

  13. Status report on the Los Alamos proton storage ring

    International Nuclear Information System (INIS)

    Colton, E.; Neuffer, D.; Thiessen, H.A.

    1988-01-01

    The proton storage ring currently operates at an average current of 30 μA corresponding to 1.25 /times/ 10 13 protons per pulse (ppp) at a repetition rate of 15 Hz. The design operating current for the machine is 100 μA. We are limited to running at the reduced yield because of beam losses during the accumulation period. These losses are understood and arise mainly from emittance growths during the injection and multiple scattering in the stripping foil during the storage. During beam studies we have succeeded in accumulating in excess of 3.7 /times/ 10 13 ppp. We have also observed a coherent transverse instability at high charge levels. The signature for the instability is rapid coherent growth of the transverse beam size followed by a loss of beam in the machine. The threshold for the instability depends most strongly upon rf voltage and beam size. 3 refs., 1 fig., 1 tab

  14. Design of a minimum emittance nBA lattice

    Science.gov (United States)

    Lee, S. Y.

    1998-04-01

    An attempt to design a minimum emittance n-bend achromat (nBA) lattice has been made. One distinct feature is that dipoles with two different lengths were used. As a multiple bend achromat, five bend achromat lattices with six superperiod were designed. The obtained emittace is three times larger than the theoretical minimum. Tunes were chosen to avoid third order resonances. In order to correct first and second order chromaticities, eight family sextupoles were placed. The obtained emittance of five bend achromat lattices is almost equal to the minimum emittance of five bend achromat lattice consisting of dipoles with equal length.

  15. Remote detection of single emitters via optical waveguides

    Science.gov (United States)

    Then, Patrick; Razinskas, Gary; Feichtner, Thorsten; Haas, Philippe; Wild, Andreas; Bellini, Nicola; Osellame, Roberto; Cerullo, Giulio; Hecht, Bert

    2014-05-01

    The integration of lab-on-a-chip technologies with single-molecule detection techniques may enable new applications in analytical chemistry, biotechnology, and medicine. We describe a method based on the reciprocity theorem of electromagnetic theory to determine and optimize the detection efficiency of photons emitted by single quantum emitters through truncated dielectric waveguides of arbitrary shape positioned in their proximity. We demonstrate experimentally that detection of single quantum emitters via such waveguides is possible, confirming the predicted behavior of the detection efficiency. Our findings blaze the trail towards efficient lensless single-emitter detection compatible with large-scale optofluidic integration.

  16. Tritium Sequestration in Gen IV NGNP Gas Stream via Proton Conducting Ceramic Pumps

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Fanglin Frank [Univ. of South Carolina, Columbia, SC (United States); Adams, Thad M. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Brinkman, Kyle [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Reifsnider, Kenneth [Univ. of South Carolina, Columbia, SC (United States)

    2011-09-30

    Several types of high-temperature proton conductors based on SrCeO3 and BaCeO3 have been systematically investigated in this project for tritium separation in NGNP applications. One obstacle for the field application is the chemical stability issues in the presence of steam and CO2 for these proton conductors. Several strategies to overcome such issues have been evaluated, including A site doping and B site co-doping method for perovskite-structured proton conductors. Novel zirconium-free proton conductors have also been developed with improved electrical conductivity and enhanced chemical stability. Novel catalytic materials for the proton-conducting separation membranes have been investigated. A tubular geometry proton-conducting membrane has been developed for the proton separation membranes. Total dose rate estimated from tritium decay (beta emission) under realistic membrane operating conditions, combined with electron irradiation experiments, indicates that proton ceramic materials possess the appropriate radiation stability for this application.

  17. In Vitro Studies on Space Radiation-Induced Delayed Genetic Responses: Shielding Effects

    Science.gov (United States)

    Kadhim, Munira A.; Green, Lora M.; Gridley, Daila S.; Murray, Deborah K.; Tran, Da Thao; Andres, Melba; Pocock, Debbie; Macdonald, Denise; Goodhead, Dudley T.; Moyers, Michael F.

    2003-01-01

    Understanding the radiation risks involved in spaceflight is of considerable importance, especially with the long-term occupation of ISS and the planned crewed exploration missions. Several independent causes may contribute to the overall risk to astronauts exposed to the complex space environment, such as exposure to GCR as well as SPES. Protons and high-Z energetic particles comprise the GCR spectrum and may exert considerable biological effects even at low fluence. There are also considerable uncertainties associated with secondary particle effects (e.g. HZE fragments, neutrons etc.). The interaction of protons and high-LET particles with biological materials at all levels of biological organization needs to be investigated fully in order to establish a scientific basis for risk assessment. The results of these types of investigation will foster the development of appropriately directed countermeasures. In this study, we compared the biological responses to proton irradiation presented to the target cells as a monoenergetic beam of particles of complex composition delivered to cells outside or inside a tissue phantom head placed in the United States EVA space suit helmet. Measurements of chromosome aberrations, apoptosis, and the induction of key proteins were made in bone marrow from CBA/CaJ and C57BL/6 mice at early and late times post exposure to radiation at 0, 0.5, 1 and 2 Gy while inside or outside of the helmet. The data showed that proton irradiation induced transmissible chromosomal/genomic instability in haematopoietic stem cells in both strains of mice under both irradiation conditions and especially at low doses. Although differences were noted between the mouse strains in the degree and kinetics of transforming growth factor-beta 1 and tumor necrosis factor-alpha secretion, there were no significant differences observed in the level of the induced instability under either radiation condition, or for both strains of mice. Consequently, when

  18. Delayed coherent quantum feedback from a scattering theory and a matrix product state perspective

    Science.gov (United States)

    Guimond, P.-O.; Pletyukhov, M.; Pichler, H.; Zoller, P.

    2017-12-01

    We study the scattering of photons propagating in a semi-infinite waveguide terminated by a mirror and interacting with a quantum emitter. This paradigm constitutes an example of coherent quantum feedback, where light emitted towards the mirror gets redirected back to the emitter. We derive an analytical solution for the scattering of two-photon states, which is based on an exact resummation of the perturbative expansion of the scattering matrix, in a regime where the time delay of the coherent feedback is comparable to the timescale of the quantum emitter’s dynamics. We compare the results with numerical simulations based on matrix product state techniques simulating the full dynamics of the system, and extend the study to the scattering of coherent states beyond the low-power limit.

  19. Movement of Irrigation Water in Soil from a Surface Emitter

    Directory of Open Access Journals (Sweden)

    Ibrahim Abbas Dawood

    2016-09-01

    Full Text Available rickle irrigation is one of the most conservative irrigation techniques since it implies supplying water directly on the soil through emitters. Emitters dissipate energy of water at the end of the trickle irrigation system and provide water at emission points. The area wetted by an emitter depends upon the discharge of emitter, soil texture, initial soil water content, and soil permeability. The objectives of this research were to predict water distribution profiles through different soils for different conditions and quantify the distribution profiles in terms of main characteristics of soil and emitter. The wetting patterns were simulated at the end of each hour for a total time of application of 12 hrs, emitter discharges of 0.5, 0.75, 1, 2, 3, 4, and 5 lph, and five initial volumetric soil water contents. Simulation of water flow from a single surface emitter was carried out by using the numerically-based software Hydrus-2D/3D, Version 2.04. Two approaches were used in developing formulas to predict the domains of the wetted pattern. In order to verify the results obtained by implementing the software Hydrus-2D/3D a field experiment was conducted to measure the wetted diameter and compare measured values with simulated ones. The results of the research showed that the developed formulas to express the wetted diameter and depth in terms of emitter discharge, time of application, and initial soil water content are very general and can be used with very good accuracy.

  20. Development of methodology for detection of long lived alpha emitters in air based on simultaneous alpha and beta activity measurement

    International Nuclear Information System (INIS)

    Kaushik, Vivek; Rath, D.P.; Vinayagami, Bhakti; Ashokkumar, P.; Umashankar, C.; Gopalakrishnan, R.K.; Kulkarni, M.S.

    2018-01-01

    Interference of the radon and thoron progeny co-deposited on the filtration media is the long-standing problem related to prompt analyses in continuous air sampling or monitoring of any potential suspect radionuclides. The solutions to this problem have been quite diverse, and included, for example, simple gross-alpha counting, the use of beta-to-alpha ratios, and the use of alpha spectrum analyses. The techniques based on beta to alpha disintegration ratios make use of the naturally occurring alpha to beta disintegration ratios and departures therefrom. This ratio is found empirically to be relatively constant. With the help of the solution of differential equation, which govern the deposition of radionuclide on filter paper, one can easily estimate theoretically the behavior of the radon progeny alpha to beta disintegration (or count) rate ratio

  1. Jamming of Quantum Emitters by Active Coated Nanoparticles

    DEFF Research Database (Denmark)

    Arslanagic, Samel; Ziolkowski, Richard W.

    2013-01-01

    to effectively cloak the emitters to a far-field observer is reported and explained through thorough near- and far-field investigations. This property offers an interesting route toward the jamming of quantum emitters/nanoantennas that might be of potential use, for instance, in biological fluorescence assays...

  2. Measurement of elastic proton-proton scattering at $\\sqrt{s} = 7$ TeV with the ALFA sub-detector of ATLAS at the LHC

    CERN Document Server

    Kreutzfeldt, Kristof; Stenzel, Hasko

    The ATLAS experiment with the ALFA sub-detector, provides a unique opportunity to measure elastic proton--proton scattering at the LHC at a centre-of-mass energy of $\\sqrt{s} = 7$ TeV, that has never been reached before. The ALFA detector is a tracking detector housed in Roman Pots, which makes it possible to measure elastically scattered protons down to very small scattering angles. From the proton tracks, measured during a LHC fill with special $\\beta^{*} = 90$ m beam optics, the differential elastic cross-section as a function of the four-momentum transfer squared $t$ is determined, and the total hadronic cross-section $\\sigma_\\text{tot}$, the nuclear slope parameter $B$ and further derived quantities are extracted by utilizing the optical theorem. The total hadronic cross-section is a fundamental parameter of strong interaction depending on the centre-of-mass energy. It has been measured for more than 50 years at different energies and accelerators, where a rise with energy was observed. A newly developed...

  3. Electro-optical properties of dislocations in silicon and their possible application for light emitters

    Energy Technology Data Exchange (ETDEWEB)

    Arguirov, Tzanimir Vladimirov

    2007-10-14

    This thesis addresses the electro-optical properties of silicon, containing dislocations. The work demonstrates that dislocation specific radiation may provide a means for optical diagnostics of solar cell grade silicon. It provides insight into the mechanisms governing the dislocation recombination activity, their radiation, and how are they influenced by other defects present in silicon. We demonstrate that photoluminescence mapping is useful for monitoring the recombination activity in solar cell grade silicon and can be applied for identification of contaminants, based on their photoluminescence signatures. It is shown that the recombination at dislocations is strongly influenced by the presence of metals at the dislocation sites. The dislocation radiation activity correlates with their electrical activity. It is shown that the dislocation and band-to-band luminescence are essentially anti-correlated. {beta}FeSi{sub 2} precipitates, with a luminescence at 0.8 eV, were detected within the grains of block cast materials. They exhibit a characteristic feature of quantum dots, namely blinking. The second aspect of the thesis concerns the topic of silicon based light emitters for on-chip optical interconnects. The goal is an enhancement of sub-band-gap or band-to-band radiation by controlled formation of dislocation-rich areas in microelectronics-grade silicon as well as understanding of the processes governing such enhancement. For light emitters based on band-to-band emission it is shown, that internal quantum efficiency of nearly 2 % can be achieved, but the emission is essentially generated in the bulk of the wafer. On the other hand, light emitters utilizing the emission from dislocation-rich areas of a well localized wafer depth were explored. Three different methods for reproducible formation of a dislocation-rich region beneath the wafer surface were investigated and evaluated in view of their room temperature sub-band-gap radiation: (1) silicon implantation

  4. Fluorescence and room temperature phosphorescence of 6-bromo-2-naphthol in {beta}-cyclodextrin solution and its selective molecular recognition for cyclohexane

    Energy Technology Data Exchange (ETDEWEB)

    Zhai Yanqiang; Zhang Shuzhen; Xie Jianwei; Liu Changsong

    2003-10-08

    The room temperature phosphorescence (RTP) and fluorescence behavior of 6-bromo-2-naphthol (BN) in water and {beta}-cyclodextrin ({beta}-CD) aerated aqueous solution was investigated. The study of fluorescence behavior at different pH values indicated that three kinds of species of BN (protonated, uncharged and anionic species) formed 1:1 inclusion complexes with {beta}-CD, and RTP and fluorescence emission depended on the pH of the solution. The inclusion complex constants were 430{+-}25 l mol{sup -1} (pH 1.80), 840{+-}25 l mol{sup -1} (pH 5.80), 1850{+-}75 l mol{sup -1} (pH 11.50), respectively. Experimental results elucidated that RTP of the BN/{beta}-CD/cyclohexane solution came from the protonated and uncharged species of BN, but not from the anionic species, though the inclusion constant of the anionic species of BN with {beta}-CD was larger than that of the other two species of BN Selective molecular recognition of BN/{beta}-CD as an RTP sensor for 28 small organic molecules was studied, it was shown that BN/{beta}-CD could be develop as a new RTP sensor with high selectivity molecular recognition ability for cyclohexane.

  5. Emittance increase caused by core depletion in collisions

    CERN Document Server

    Bruce, R

    2009-01-01

    A new effect is presented, which changes the emittance during colliding-beam operation in circular colliders. If the initial transverse distribution is Gaussian, the collision probability is much higher for particles in the core of the beam than in the tails. When small-amplitude particles are removed, the remaining ones therefore have a larger transverse emittance. This effect, called core depletion, may cause a decrease in luminosity. An approximate analytic model is developed to study the effect and benchmarked against a multiparticle tracking simulation. Finally, the time evolution of the intensity and emittances of a Pb bunch in the Large Hadron Collider (LHC) at CERN is calculated, taking into account also other processes than collisions. The results show that integrated luminosity drops by 3--4% if core depletion is taken into account. It is also found that core depletion causes the transverse emittance to be larger when more experiments are active. This observation could be checked against experimenta...

  6. Selective solar absorber emittance measurement at elevated temperature

    Science.gov (United States)

    Giraud, Philémon; Braillon, Julien; Raccurt, Olivier

    2017-06-01

    Durability of solar components for CSP (Concentrated Solar Power Plant) technologies is a key point to lower cost and ensure their large deployment. These technologies concentrated the solar radiation by means of mirrors on a receiver tube where it is collected as thermal energy. The absorbers are submitted to strong environmental constraints and the degradation of their optical properties (emittance and solar absorbance) have a direct impact on performance. The characterization of a material in such condition is complicated and requires advanced apparatuses, and different measurement methods exist for the determination of the two quantities of relevance regarding an absorber, which are its emittance and its solar absorbance. The objective is to develop new optical equipment for measure the emittance of this solar absorber at elevated temperature. In this paper, we present an optical bench developed for emittance measurement on absorbers is conditions of use. Results will be shown, with a discussion of some factors of influence over this measurement and how to control them.

  7. Physics with tagged forward protons at RHIC

    Energy Technology Data Exchange (ETDEWEB)

    Yip,K.

    2009-08-30

    The physics reach of the STAR detector at RHIC has been extended to include elastic and inelastic diffraction measurements with tagged forward protons. This program has started at RHIC in p+p collisions with a special optics run of {beta}* {approx} 21 m at STAR, at the center-of-mass energy {radical}s = 200 GeV during the last week of the RHIC 2009 run.

  8. Strong coupling of collection of emitters on hyperbolic meta-material

    Science.gov (United States)

    Biehs, Svend-Age; Xu, Chenran; Agarwal, Girish S.

    2018-04-01

    Recently, considerable effort has been devoted to the realization of a strong coupling regime of the radiation matter interaction in the context of an emitter at a meta surface. The strong interaction is well realized in cavity quantum electrodynamics, which also show that strong coupling is much easier to realize using a collection of emitters. Keeping this in mind, we study if emitters on a hyperbolic meta materials can yield a strong coupling regime. We show that strong coupling can be realized for densities of emitters exceeding a critical value. A way to detect strong coupling between emitters and hyperbolic metamaterials is to use the Kretschman-Raether configuration. The strong coupling appears as the splitting of the reflectivity dip. In the weak coupling regime, the dip position shifts. The shift and splitting can be used to sense active molecules at surfaces.

  9. High intensity proton linac activities at Los Alamos

    International Nuclear Information System (INIS)

    Rusnak, B.; Chan, K.C.; Campbell, B.

    1998-01-01

    High-current proton linear accelerators offer an attractive alternative for generating the intense neutron fluxes needed for transmutations technologies, tritium production and neutron science. To achieve the fluxes required for tritium production, a 100-mA, 1700-MeV cw proton accelerator is being designed that uses superconducting cavities for the high-energy portion of the linac, from 211 to 1,700 MeV. The development work supporting the linac design effort is focused on three areas: superconducting cavity performance for medium-beta cavities at 700 MHz, high power rf coupler development, and cryomodule design. An overview of the progress in these three areas is presented

  10. Proton acceleration: new developments for focusing and energy selection, and applications in plasma physics

    Science.gov (United States)

    Audebert, P.

    2007-11-01

    In the last few years, intense research has been conducted on laser-accelerated ion sources and their applications. These sources have exceptional properties, i.e. high brightness and high spectral cut-off, high directionality and laminarity, short burst duration. We have shown that for proton energies >10 MeV, the transverse and longitudinal emittance are respectively example point-projection radiography with unprecedented resolution. We will show example of such time and space-resolved radiography of fast evolving fields, either of associated with the expansion of a plasma in vacuum [*] or with the propagation of a ICF-relevant laser beam in an underdense plasma. These proton sources also open new opportunities for ion beam generation and control, and could stimulate development of compact ion accelerators for many applications.

  11. Radial arrays of nano-electrospray ionization emitters and methods of forming electrosprays

    Science.gov (United States)

    Kelly, Ryan T [West Richland, WA; Tang, Keqi [Richland, WA; Smith, Richard D [Richland, WA

    2010-10-19

    Electrospray ionization emitter arrays, as well as methods for forming electrosprays, are described. The arrays are characterized by a radial configuration of three or more nano-electrospray ionization emitters without an extractor electrode. The methods are characterized by distributing fluid flow of the liquid sample among three or more nano-electrospray ionization emitters, forming an electrospray at outlets of the emitters without utilizing an extractor electrode, and directing the electrosprays into an entrance to a mass spectrometry device. Each of the nano-electrospray ionization emitters can have a discrete channel for fluid flow. The nano-electrospray ionization emitters are circularly arranged such that each is shielded substantially equally from an electrospray-inducing electric field.

  12. The cataphoretic emitter effect exhibited in high intensity discharge lamp electrodes

    Science.gov (United States)

    Mentel, Juergen

    2018-01-01

    A mono-layer of atoms, electropositive with respect to the substrate atoms, forms a dipole layer, reducing its work function. Such a layer is generated by diffusion of emitter material from the interior of the substrate, by vapour deposition or by deposition of emitter material onto arc electrodes by cataphoresis. This cataphoretic emitter effect is investigated within metal halide lamps with transparent YAG ceramic burners, and within model lamps. Within the YAG lamps, arcs are operated with switched-dc current between rod shaped tungsten electrodes in high pressure Hg vapour seeded with metal iodides. Within the model lamps, dc arcs are operated between rod-shaped tungsten electrodes—one doped—in atmospheric pressure Ar. Electrode temperatures are determined by 1λ -pyrometry, combined with simulation of the electrode heat balance. Plasma temperatures, atom and ion densities of emitter material are determined by emission and absorption spectroscopy. Phase resolved measurements in YAG lamps seeded with CeI3, CsI, DyI3, TmI3 and LaI3 show, within the cathodic half period, a reduction of the electrode temperature and an enhanced metal ion density in front of the electrode, and an opposite behavior after phase reversal. With increasing operating frequency, the state of the cathode overlaps onto the anodic phase—except for Cs, being low in adsorption energy. Generally, the phase averaged electrode tip temperature is reduced by seeding a lamp with emitter material; its height depends on admixtures. Measurements at tungsten electrodes doped with ThO2, La2O3 and Ce2O3 within the model lamp show that evaporated emitter material is redeposited by an emitter ion current onto the electrode surface. It reduces the work function of tungsten cathodes above the evaporation temperature of the emitter material, too; and also of cold anodes, indicating a field reversal in front of them. The formation of an emitter spot at low cathode temperature and high emitter material

  13. Low emittance lattices for electron storage rings revisited

    International Nuclear Information System (INIS)

    Trbojevic, D.; Courant, E.

    1994-01-01

    Conditions for the lowest possible emittance of the lattice for electron storage rings are obtained by a simplified analytical approach. Examples of electron storage lattices with minimum emittances are presented. A simple graphical presentation in the normalized dispersion space (Floquet's transformation) is used to illustrate the conditions and results

  14. Double beta decay of Uranium-238: Proton reactions of 238U in 5--12 MeV range. Final report, April 15, 1987--March 31, 1992

    International Nuclear Information System (INIS)

    Turkevich, A.; Economou, T.E.

    1993-01-01

    This report is in two parts. The first part reports on the experimental work determining the half-life for double beta decay of 238 U to 238 PU to be (2.0 ± 0.6) x 10 21 years. This is the first evidence for a third mode of decay of this heaviest naturally occurring nucleus. This rate is about 10 6 times slower than spontaneous fission, which itself is about 10 6 times slower than alpha decay. The implication of this double beta decay to neutrino masses depends on uncertain theoretical calculations of the rate for such a heavy nucleus. The second part reports on yields of principal fission products from 5.6, 7.3, 9.4, and 11.5 MeV proton interactions with 238 U. The yields at 11.5 MeV are similar to those from 14 MeV neutron fission of 238 U. At the same time, the production cross sections of 238 Np at the same energies are determined. This nuclide is produced as often as fission at the lowest energy but only 3.8% as often at the highest energy

  15. Combined inclusive diffractive cross sections measured with forward proton spectrometers in deep inelastic ep scattering at HERA

    CERN Document Server

    Aaron, F.D.; Abt, I.; Adamczyk, L.; Adamus, M.; Aggarwal, R.; Alexa, C.; Andreev, V.; Antonelli, S.; Antonioli, P.; Antonov, A.; Arneodo, M.; Arslan, O.; Aushev, V.; Aushev, Y.; Bachynska, O.; Backovic, S.; Baghdasaryan, A.; Baghdasaryan, S.; Bamberger, A.; Barakbaev, A.N.; Barbagli, G.; Bari, G.; Barreiro, F.; Barrelet, E.; Bartel, W.; Bartosik, N.; Bartsch, D.; Basile, M.; Begzsuren, K.; Behnke, O.; Behr, J.; Behrens, U.; Bellagamba, L.; Belousov, A.; Belov, P.; Bertolin, A.; Bhadra, S.; Bindi, M.; Bizot, J.C.; Blohm, C.; Bokhonov, V.; Bondarenko, K.; Boos, E.G.; Borras, K.; Boscherini, D.; Bot, D.; Boudry, V.; Bozovic-Jelisavcic, I.; Bold, T.; Brummer, N.; Bracinik, J.; Brandt, G.; Brinkmann, M.; Brisson, V.; Britzger, D.; Brock, I.; Brownson, E.; Brugnera, R.; Bruncko, D.; Bruni, A.; Bruni, G.; Brzozowska, B.; Bunyatyan, A.; Bussey, P.J.; Bylinkin, A.; Bylsma, B.; Bystritskaya, L.; Caldwell, A.; Campbell, A.J.; Cantun Avila, K.B.; Capua, M.; Carlin, R.; Catterall, C.D.; Ceccopieri, F.; Cerny, K.; Cerny, V.; Chekanov, S.; Chekelian, V.; Chwastowski, J.; Ciborowski, J.; Ciesielski, R.; Cifarelli, L.; Cindolo, F.; Contin, A.; Contreras, J.G.; Cooper-Sarkar, A.M.; Coppola, N.; Corradi, M.; Corriveau, F.; Costa, M.; Coughlan, J.A.; Cvach, J.; D'Agostini, G.; Dainton, J.B.; Dal Corso, F.; Daum, K.; Delcourt, B.; Delvax, J.; Dementiev, R.K.; Derrick, M.; Devenish, R.C.E.; De Pasquale, S.; De Wolf, E.A.; del Peso, J.; Diaconu, C.; Dobre, M.; Dobur, D.; Dodonov, V.; Dolgoshein, B.A.; Dolinska, G.; Dossanov, A.; Doyle, A.T.; Drugakov, V.; Dubak, A.; Durkin, L.S.; Dusini, S.; Eckerlin, G.; Egli, S.; Eisenberg, Y.; Eliseev, A.; Elsen, E.; Ermolov, P.F.; Eskreys, A.; Fang, S.; Favart, L.; Fazio, S.; Fedotov, A.; Felst, R.; Feltesse, J.; Ferencei, J.; Ferrando, J.; Ferrero, M.I.; Figiel, J.; Fischer, D.J.; Fleischer, M.; Fomenko, A.; Forrest, M.; Foster, B.; Gabathuler, E.; Gach, G.; Galas, A.; Gallo, E.; Garfagnini, A.; Gayler, J.; Geiser, A.; Ghazaryan, S.; Gialas, I.; Gizhko, A.; Gladilin, L.K.; Gladkov, D.; Glasman, C.; Glazov, A.; Goerlich, L.; Gogitidze, N.; Gogota, O.; Golubkov, Yu.A.; Gottlicher, P.; Gouzevitch, M.; Grab, C.; Grabowska-Bold, I.; Grebenyuk, A.; Grebenyuk, J.; Greenshaw, T.; Gregor, I.; Grigorescu, G.; Grindhammer, G.; Grzelak, G.; Gueta, O.; Guzik, M.; Gwenlan, C.; Huttmann, A.; Haas, T.; Habib, S.; Haidt, D.; Hain, W.; Hamatsu, R.; Hart, J.C.; Hartmann, H.; Hartner, G.; Henderson, R.C.W.; Hennekemper, E.; Henschel, H.; Herbst, M.; Herrera, G.; Hildebrandt, M.; Hilger, E.; Hiller, K.H.; Hladky, J.; Hochman, D.; Hoffmann, D.; Hori, R.; Horisberger, R.; Hreus, T.; Huber, F.; Ibrahim, Z.A.; Iga, Y.; Ingbir, R.; Ishitsuka, M.; Jacquet, M.; Jakob, H.P.; Janssen, X.; Januschek, F.; Jones, T.W.; Jonsson, L.; Jungst, M.; Jung, H.; Kadenko, I.; Kahle, B.; Kananov, S.; Kanno, T.; Kapichine, M.; Karshon, U.; Karstens, F.; Katkov, I.I.; Kaur, P.; Kaur, M.; Kenyon, I.R.; Keramidas, A.; Khein, L.A.; Kiesling, C.; Kim, J.Y.; Kisielewska, D.; Kitamura, S.; Klanner, R.; Klein, M.; Klein, U.; Kleinwort, C.; Koffeman, E.; Kogler, R.; Kondrashova, N.; Kononenko, O.; Kooijman, P.; Korol, Ie.; Korzhavina, I.A.; Kostka, P.; Kotanski, A.; Kotz, U.; Kowalski, H.; Kramer, M.; Kretzschmar, J.; Kruger, K.; Kuprash, O.; Kuze, M.; Landon, M.P.J.; Lange, W.; Lastovicka-Medin, G.; Laycock, P.; Lebedev, A.; Lee, A.; Lendermann, V.; Levchenko, B.B.; Levonian, S.; Levy, A.; Libov, V.; Limentani, S.; Ling, T.Y.; Lipka, K.; Lisovyi, M.; List, B.; List, J.; Lobodzinska, E.; Lobodzinski, B.; Lohmann, W.; Lohr, B.; Lohrmann, E.; Long, K.R.; Longhin, A.; Lontkovskyi, D.; Lopez-Fernandez, R.; Lubimov, V.; Lukina, O.Yu.; Maeda, J.; Magill, S.; Makarenko, I.; Malinovski, E.; Malka, J.; Mankel, R.; Margotti, A.; Marini, G.; Martin, J.F.; Martyn, H.U.; Mastroberardino, A.; Mattingly, M.C.K.; Maxfield, S.J.; Mehta, A.; Melzer-Pellmann, I.A.; Mergelmeyer, S.; Meyer, A.B.; Meyer, H.; Meyer, J.; Miglioranzi, S.; Mikocki, S.; Milcewicz-Mika, I.; Idris, F.Mohamad; Monaco, V.; Montanari, A.; Moreau, F.; Morozov, A.; Morris, J.V.; Morris, J.D.; Mujkic, K.; Muller, K.; Musgrave, B.; Nagano, K.; Namsoo, T.; Nania, R.; Naumann, Th.; Newman, P.R.; Niebuhr, C.; Nigro, A.; Nikitin, D.; Ning, Y.; Nobe, T.; Notz, D.; Nowak, G.; Nowak, K.; Nowak, R.J.; Nuncio-Quiroz, A.E.; Oh, B.Y.; Okazaki, N.; Olkiewicz, K.; Olsson, J.E.; Onishchuk, Yu.; Ozerov, D.; Pahl, P.; Palichik, V.; Pandurovic, M.; Papageorgiu, K.; Parenti, A.; Pascaud, C.; Patel, G.D.; Paul, E.; Pawlak, J.M.; Pawlik, B.; Pelfer, P.G.; Pellegrino, A.; Perez, E.; Perlanski, W.; Perrey, H.; Petrukhin, A.; Picuric, I.; Piotrzkowski, K.; Pirumov, H.; Pitzl, D.; Placakyte, R.; Plucinski, P.; Pokorny, B.; Pokrovskiy, N.S.; Polifka, R.; Polini, A.; Povh, B.; Proskuryakov, A.S.; Przybycien, M.; Radescu, V.; Raicevic, N.; Raval, A.; Ravdandorj, T.; Reeder, D.D.; Reimer, P.; Reisert, B.; Ren, Z.; Repond, J.; Ri, Y.D.; Rizvi, E.; Robertson, A.; Robmann, P.; Roloff, P.; Roosen, R.; Rostovtsev, A.; Rotaru, M.; Rubinsky, I.; Ruiz Tabasco, J.E.; Rusakov, S.; Ruspa, M.; Sacchi, R.; Salek, D.; Samson, U.; Sankey, D.P.C.; Sartorelli, G.; Sauter, M.; Sauvan, E.; Savin, A.A.; Saxon, D.H.; Schioppa, M.; Schlenstedt, S.; Schleper, P.; Schmidke, W.B.; Schmitt, S.; Schneekloth, U.; Schoeffel, L.; Schonberg, V.; Schoning, A.; Schorner-Sadenius, T.; Schultz-Coulon, H.C.; Schwartz, J.; Sciulli, F.; Sefkow, F.; Shcheglova, L.M.; Shehzadi, R.; Shimizu, S.; Shtarkov, L.N.; Shushkevich, S.; Singh, I.; Skillicorn, I.O.; Slominski, W.; Sloan, T.; Smith, W.H.; Sola, V.; Solano, A.; Soloviev, Y.; Son, D.; Sopicki, P.; Sosnovtsev, V.; South, D.; Spaskov, V.; Specka, A.; Spiridonov, A.; Stadie, H.; Stanco, L.; Staykova, Z.; Steder, M.; Stefaniuk, N.; Stella, B.; Stern, A.; Stewart, T.P.; Stifutkin, A.; Stoicea, G.; Stopa, P.; Straumann, U.; Suchkov, S.; Susinno, G.; Suszycki, L.; Sykora, T.; Sztuk-Dambietz, J.; Szuba, J.; Szuba, D.; Tapper, A.D.; Tassi, E.; Terron, J.; Theedt, T.; Thompson, P.D.; Tiecke, H.; Tokushuku, K.; Tomaszewska, J.; Tran, T.H.; Traynor, D.; Truol, P.; Trusov, V.; Tsakov, I.; Tseepeldorj, B.; Tsurugai, T.; Turcato, M.; Turkot, O.; Turnau, J.; Tymieniecka, T.; Vazquez, M.; Valkarova, A.; Vallee, C.; Van Mechelen, P.; Vazdik, Y.; Verbytskyi, A.; Viazlo, O.; Vlasov, N.N.; Walczak, R.; Wan Abdullah, W.A.T.; Wegener, D.; Whitmore, J.J.; Wichmann, K.; Wiggers, L.; Wing, M.; Wlasenko, M.; Wolf, G.; Wolfe, H.; Wrona, K.; Wunsch, E.; Yagues-Molina, A.G.; Yamada, S.; Yamazaki, Y.; Yoshida, R.; Youngman, C.; Zabiegalov, O.; Zacek, J.; Zalesak, J.; Zawiejski, L.; Zenaiev, O.; Zeuner, W.; Zhang, Z.; Zhautykov, B.O.; Zhmak, N.; Zhokin, A.; Zichichi, A.; Zlebcik, R.; Zohrabyan, H.; Zolkapli, Z.; Zomer, F.; Zotkin, D.S.; Zarnecki, A.F.

    2012-10-10

    A combination of the inclusive diffractive cross section measurements made by the H1 and ZEUS Collaborations at HERA is presented. The analysis uses samples of diffractive deep inelastic ep scattering data at a centre-of-mass energy sqrt(s) = 318 GeV where leading protons are detected by dedicated spectrometers. Correlations of systematic uncertainties are taken into account, resulting in an improved precision of the cross section measurement which reaches 6% for the most precise points. The combined data cover the range 2.5 < Q2 < 200 GeV2 in photon virtuality, 0.00035 < xIP < 0.09 in proton fractional momentum loss, 0.09 < |t| < 0.55 GeV2 in squared four-momentum transfer at the proton vertex and 0.0018 < beta < 0.816 in beta = x/xIP, where x is the Bjorken scaling variable.

  16. BEAM EMITTANCE MEASUREMENT TOOL FOR CEBAF OPERATIONS

    International Nuclear Information System (INIS)

    Chevtsov, Pavel; Tiefenback, Michael

    2008-01-01

    A new software tool was created at Jefferson Lab to measure the emittance of the CEBAF electron beams. The tool consists of device control and data analysis applications. The device control application handles the work of wire scanners and writes their measurement results as well as the information about accelerator settings during these measurements into wire scanner data files. The data analysis application reads these files and calculates the beam emittance on the basis of a wire scanner data processing model. Both applications are computer platform independent but are mostly used on LINUX PCs recently installed in the accelerator control room. The new tool significantly simplifies beam emittance measurement procedures for accelerator operations and contributes to a very high availability of the CEBAF machine for the nuclear physics program at Jefferson Lab.

  17. Decay of the high-spin isomer in 160Re: Changing single-particle structure beyond the proton drip line

    International Nuclear Information System (INIS)

    Darby, I.G.; Page, R.D.; Joss, D.T.; Simpson, J.; Bianco, L.; Cooper, R.J.; Eeckhaudt, S.; Ertuerk, S.; Gall, B.; Grahn, T.; Greenlees, P.T.; Hadinia, B.; Jones, P.M.; Judson, D.S.; Julin, R.; Juutinen, S.; Ketelhut, S.; Leino, M.; Leppaenen, A.-P.; Nyman, M.

    2011-01-01

    A new high-spin isomeric state (t 1/2 =2.8±0.1 μs) in 160 Re has been identified. This high-spin isomer is unique in that it only decays by γ-decay and not by proton or α-particle emission as is the case in every other proton emitter between Z=64 and 80. Shell model calculations indicate how the convergence of the h 9/2 and f 7/2 neutron levels in this region could open up a γ-decay path from the high-spin isomer to the low-spin ground state of 160 Re, providing a natural explanation for this anomalous absence of charged-particle emission. The consequences of these observations for future searches for proton emission from even more exotic nuclei and in-beam spectroscopic studies are considered.

  18. Low energy proton irradiation effects on InP/InGaAs DHBTs and InP-base frequency dividers

    Science.gov (United States)

    Zhang, Xingyao; Li, Yudong; Guo, Qi; Feng, Jie

    2018-03-01

    InP/InGaAs DHBTs and frequency dividers are irradiated by low energy proton, and displacement damage effect of the devices are analyzed. InP/InGaAs DHBTs has been made DC characteristics measurements, and the function measurement for frequency dividers has been done both before and after proton irradiation. The breakdown voltage of InP DHBTs drop to 3.7V When the fluence up to 5x1013 protons/cm2. Meanwhile, the function of frequency dividers get out of order. Degradation of DC characteristics of DHBTs are due to the radiation-induced defects in the quasi neutral base and the space charge region of base-collector and base-emitter junctions. The performance deterioration of DHBTs induce the fault of frequency dividers, and prescaler may be the most sensitive circuit.

  19. Achievement of ultralow emittance coupling in the Australian Synchrotron storage ring

    Directory of Open Access Journals (Sweden)

    R. Dowd

    2011-01-01

    Full Text Available Investigations into producing an electron beam with ultralow vertical emittance have been conducted using the Australian Synchrotron 3 GeV storage ring. A method of tuning the emittance coupling (ϵ_{y}/ϵ_{x} has been developed using a machine model calibrated through the linear optics from closed orbits method. Direct measurements of the beam emittance have not been possible due to diagnostic limitations, however two independent indirect measurements both indicate a vertical emittance of 1.2–1.3 pm rad (ϵ_{y}/ϵ_{x}=0.01%. Other indirect measurements support the validity of these results. This result is the smallest vertical emittance currently achieved in a storage ring.

  20. Measurements of Transverse Emittance for RF Photocathode Gun at the PAL

    CERN Document Server

    Park Jang Ho; Park, Sung-Ju; Soo Ko In; Wang, Xijie; Woon Parc, Yong; Xiang, Dao

    2005-01-01

    A BNL GUN-IV type RF photo-cathode gun is under fabrication for use in the FIR (Far Infra-Red) facility being built at the Pohang Accelerator Laboratory (PAL). Performance test of the gun will include the measurement of transverse emittance profile along the longitudinal direction. Successful measurement of the emittance profile will provide powerful tool for the commissioning of the 4GLS (4th generation light source) injectors based on the emittance compensation principle. We are going to achieve this withthe use of pepper-pot based emittance meters that can be moved along the longitudinal direction. In this article, we present design considerations on the emittance meter with the resolution of 1 mm mrad.