WorldWideScience

Sample records for beta sources

  1. Dosimetry of {beta} extensive sources; Dosimetria de fuentes {beta} extensas

    Energy Technology Data Exchange (ETDEWEB)

    Rojas C, E.L.; Lallena R, A.M. [Departamento de Fisica Moderna, Universidad de Granada, E-18071 Granada (Spain)

    2002-07-01

    In this work, we have been studied, making use of the Penelope Monte Carlo simulation code, the dosimetry of {beta} extensive sources in situations of spherical geometry including interfaces. These configurations are of interest in the treatment of the called cranealfaringyomes of some synovia leisure of knee and other problems of interest in medical physics. Therefore, its application can be extended toward problems of another areas with similar geometric situation and beta sources. (Author)

  2. Source preparations for alpha and beta measurements

    Energy Technology Data Exchange (ETDEWEB)

    Holm, E. [Risoe National Lab., Roskilde (Denmark)

    2001-01-01

    Regarding alpha particle emitters subject for environmental studies, electrodeposition or co-precipitation as fluorides are the most common methods. For electro deposition stainless steel is generally used as cathode material but also other metals such as Ni, Ag, and Cu showed promising results. The use of other anode material than platinum, such as graphite should be investigated. For other purposes such as optimal resolution other more sophisticated methods are used but often resulting in poorer recovery. For beta particle emitters the type of detection system will decide the source preparation. Similar methods as for alpha particle emitters, electrodeposition or precipitation techniques can be used. Due to the continuous energy distribution of the beta pulse height distribution a high resolution is not required. Thicker sources from the precipitates or a stable isotopic carrier can be accepted but correction for absorption in the source must be done. (au)

  3. Source preparations for alpha and beta measurements

    International Nuclear Information System (INIS)

    Regarding alpha particle emitters subject for environmental studies, electrodeposition or co-precipitation as fluorides are the most common methods. For electro deposition stainless steel is generally used as cathode material but also other metals such as Ni, Ag, and Cu showed promising results. The use of other anode material than platinum, such as graphite should be investigated. For other purposes such as optimal resolution other more sophisticated methods are used but often resulting in poorer recovery. For beta particle emitters the type of detection system will decide the source preparation. Similar methods as for alpha particle emitters, electrodeposition or precipitation techniques can be used. Due to the continuous energy distribution of the beta pulse height distribution a high resolution is not required. Thicker sources from the precipitates or a stable isotopic carrier can be accepted but correction for absorption in the source must be done. (au)

  4. Sources of beta cells inside the pancreas.

    Science.gov (United States)

    De Groef, Sofie; Staels, Willem; Van Gassen, Naomi; Lemper, Marie; Yuchi, Yixing; Sojoodi, Mozhdeh; Bussche, Leen; Heremans, Yves; Leuckx, Gunter; De Leu, Nico; Van de Casteele, Mark; Baeyens, Luc; Heimberg, Harry

    2016-09-01

    The generation of beta(-like) cells to compensate for their absolute or relative shortage in type 1 and type 2 diabetes is an obvious therapeutic strategy. Patients first received grafts of donor islet cells over 25 years ago, but this procedure has not become routine in clinical practice because of a donor cell shortage and (auto)immune problems. Transplantation of differentiated embryonic and induced pluripotent stem cells may overcome some but not all the current limitations. Reprogramming exocrine cells towards functional beta(-like) cells would offer an alternative abundant and autologous source of beta(-like) cells. This review focuses on work by our research group towards achieving such a source of cells. It summarises a presentation given at the 'Can we make a better beta cell?' symposium at the 2015 annual meeting of the EASD. It is accompanied by two other reviews on topics from this symposium (by Amin Ardestani and Kathrin Maedler, DOI: 10.1007/s00125-016-3892-9 , and by Heiko Lickert and colleagues, DOI: 10.1007/s00125-016-3949-9 ) and a commentary by the Session Chair, Shanta Persaud (DOI: 10.1007/s00125-016-3870-2 ). PMID:27053238

  5. 21 CFR 886.5100 - Ophthalmic beta radiation source.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic beta radiation source. 886.5100 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5100 Ophthalmic beta radiation source. (a) Identification. An ophthalmic beta radiation source is a device intended to apply...

  6. The Technology and Applications of Large Fission Product Beta Sources

    International Nuclear Information System (INIS)

    Beta emitters have not received consideration as large sources of radiation power because in the past, the radiation processes of interest have been based on particles with high penetration power; hence the great emphasis on gammas and artificially accelerated electrons. About four years ago, it became apparent that a broad field of potential applications involving surface radiation treatment was developing, e. g. surface modification of formed plastics by graft copolymerization and surface pasteurization of food. For these applications, penetration in depth is wasteful and potentially harmful. Also there are two other areas for which machine electrons were not well suited: radiation-induced chemical syntheses in pressure vessels, and certain types of free radical chain reactions for which the production rate per kilowatt decreases with the square root of the dose rate. Broad area beta sources showed obvious potential advantages in all these categories and, since they are available in good yield from the fission process, merited a careful re-appraisal. On the basics of these considerations an AEC sponsored study of the applications and technology of fission product beta sources was performed. The results indicate the following: 1. There are promising areas for commercial application of fission product beta emitters in the radiation processing field, particularly in the graft copolymerization modification of formed plastic surfaces and textiles. 2. Massive, rugged, inert, safe, inexpensive beta sources may be fabricated by suitable extensions of existing techniques. Source-bearing glass formulations show particular promise. 3. Beta absorption calculations indicate that extended sources can be designed with power utilization efficiencies as high as 20 per cent. Equations and curves describing dosage and beta utilization efficiency as a function of the geometry and composition of various source-target systems were developed. An experimental program is in progress to

  7. A new irradiated quartz for beta source calibration

    DEFF Research Database (Denmark)

    Hansen, Vicki; Murray, Andrew Sean; Buylaert, Jan-Pieter; Yeo, Eun-Young; Thomsen, Kristina Jørkov

    2015-01-01

    For luminescence dating to be an accurate absolute dating technique it is very important that we are able to deliver absolutely known radiation doses in the laboratory. This is normally done using a radiation source (alpha, beta, X-ray) calibrated against an absolutely known reference source. Many...... laboratories have used the various different batches of Risø calibration quartz for the calibration of beta and X-ray sources, but these have been largely undescribed. Here we describe in detail the preparation and luminescence characteristics of a new quartz standard, based on a North Sea beach sand collected...... from south-western Denmark (Rømø). Two grain sizes (4-11μm and 180-250μm) have been examined in detail. These were pre-treated (annealed, dosed and annealed again) to sensitise and stabilise the luminescence signals before being given an absolutely known gamma dose from a point 137Cs source in scatter...

  8. Dosimetry of beta sources utilized in nuclear medicine and biomedicine

    International Nuclear Information System (INIS)

    Full text: The use of high energy pure beta sources (i.e., 32P= 1.71 MeV/des) is common in medicine (intratumoral therapy or treatment of non-malignant illness as restenosis) and in biochemistry (molecular biology). The external dosimetry of these sources offers some important points that must be considered: 1) beta particles emitted by the source are not monoenergetic; 2) the range (R0) vary with the source energy and the Z of the absorber; 3) below an energy of 1 MeV, the specific ionization in the absorbent medium (air, water, lucite) increases as the beta energy (Eβ) decreases; 4) the range of beta particles, Rβ, is independent from Z of the material, provided Z is low and the material has no hydrogen; in this case, the expression: Rβ δ1 = Rβ δ2 is valid; 5) the calculation of the external beta dosimetry must consider that since the used sources are not punctual there is self-absorption which should be taken into account. However, in the range of the fractions of activities for the above mentioned practices a theoretical model for punctual sources can be used; in this case, it is valid to use the expression: Dose Rate: = A (S/δ)Eβ e-S/δδx/4 π d2, where: (S/δ) is the absorbent Mass Stopping Power and represents the loss of energy by unit mass thickness; it depends from Eβ and it is independent from Z; (δx) is the mass thickness of the absorber. By this way, e -S/δδx is the attenuation of the beta particles flow. From the application of this formula it can be deduced that, for sources of 1 mCi of 32P activities, as those employed in biochemistry, a small thickness of lucite is enough shield. When the source has higher activities, as those used in radiotherapy, the operator should take into account the regulations for a strict dosimetric control. These formulae allow a simplified calculation of the 32P dosimetry of sources used in nuclear medicine and biomedical practices. (author)

  9. The treatment as tritium wastes of expired beta light sources

    International Nuclear Information System (INIS)

    After about 10 years of operation, the loss of luminance of the beta light sources amounts up to 75% and consequently, their replacement is required. The storage without conditioning of expired sources as radioactive wastes is not recommended due to the fragility of their glass envelope and to the gaseous state of the radioactive material. Different technological procedures for beta light source treatment were identified. Technological principles consist in breaking the expired sources in a vacuum chamber followed by: (a) 3 He-3 H mixture separation and selective absorption of tritium on the 238 U; (b) Na3H and NaB3H synthesis or; (c) catalytic oxidation at T2O and CH3COOT synthesis by hydrolysis of acetic anhydride. Resulting contaminated gases were oxidized at HTO (liquid tritium waste). The storage of HTO, as conditioned radioactive waste requires its incorporation in absorbed materials, the most utilized being silica gel and zeolites. Due to its high capacity for water absorption, the polyacrylic acids (PAA) represent an interesting alternative for HTO storage. Simulation of self radiolytic processes was realized using the gamma radiation field emitted by an irradiation source of 60 Co (IETI 10000 - NIPNE-HH) which ensures a maximum of absorbed dose rate of 3 kGy (0.3 Mrad/h). The test was performed on hydrogels with various swelling degrees (PAA:water from 1:1 to 1:300) and absorbed doses between 0.1 and 20 kGy. The gel/sol ratio variation of PAA hydrogels was analyzed. (authors)

  10. Calibrating instrument of plane sources of alpha and beta

    International Nuclear Information System (INIS)

    The instrument is standard instrument for measuring emissivity of plane sources of alpha and beta under 2π geometry in radionuclide metrologic technique. It is composed of box-type detector and truck-type NIM (made in China) to make up integral equipment. Its detector is composed of multivire proportion counter with electrostatic screen of zero potential and unique anticoincidence multiwire proportion counter in lead chamber. The characteristics of the instrument are as follows: Low background (α≤ 0.006 C · P · M/cm2, β≤ 0.03 C · P · M/cm2), low work voltage, low noise, high detective efficiency (>99%), large sensitive area (150 x 100 mm), less dead time, possessing micro accidental anticoincidences, better property of high voltage plateau and discriminating. It has fulfiled the requirements of standard which possesses wide rang (50 C · M · M ∼ 106 C · P · M), high precision (± 5 ∼ 6% for 50 C · P · M ∼ 220 C · P · M, ≤ ± 0.6% for 200 C · P · M ∼ 106 C · P · M); besides, have solved the problem of instability which usualy occurs in same kind of equipments for measuring a sources with less face conductivity

  11. SOURCE 1ST 2.0: development and beta testing

    International Nuclear Information System (INIS)

    SOURCE 1ST 2.0 is the Industry Standard fission product release code that is being developed by Ontario Power Generation, New Brunswick Power, Hydro-Quebec, and Atomic Energy of Canada Ltd. This paper is a report on recent progress on requirement specification, code development, and module verification and validation activities. The theoretical basis for each model in the code is described in a module Software Theory Manual. The development of SOURCE IST 2.0 has required code design decisions about how to implement the software requirements. Development and module testing of the β1 release of SOURCE IST 2.0 (released in July 1999) have led to some interesting insights into fission product release modelling. The beta testing process has allowed code developers and analysts to refine the software requirements for the code. The need to verify physical reference data has guided some decisions on the code and data structure design. Examples of these design decisions are provided. Module testing, and verification and validation activities are discussed. These activities include code-targeted testing, stress testing, code inspection, comparison of code with requirements, and comparison of code results with independent algebraic, numerical, or semi-algebraic calculations. The list of isotopes to be modelled by SOURCE IST 2.0 provides an example of a subset of a reference data set. Isotopes are present on the list for a variety of reasons: personnel or public dose, equipment dose (for environmental qualification), fission rate and actinide modelling, or stable (or long-lived) targets for activation processes. To accommodate controlled changes to the isotope list, the isotope list and associated nuclear data are contained in a reference data file. The questions of multiple computing platforms, and of Year 2000 compliance have been addressed by programming rules for the code. By developing and testing modules on most of the different platforms on which the code is intended

  12. Guidelines for the calibration of low energy photon sources at beta-ray brachytherapy sources

    International Nuclear Information System (INIS)

    Kerma Rate. In this document the latter recommendation is adopted. Both of the quantities give the same numerical value for the source strength and differ only in the units they are expressed. The recommended dose calculation method is discussed further in the text. Sealed beta-ray sources for brachytherapy treatments have been in use for few decades already. An example is application of 90Sr/90Y planar sources for ophthalmic brachytherapy treatments. For these types of treatments, a precise dose distribution within the eye globe is needed. Modern diagnostic techniques permit the determination of all volumes of interest in the eye, i.e. tumor and critical structures such as optic disc and iris with a high precision. It is therefore of importance to optimize the treatment by limiting the dose to these critical structures. A relatively new and rapidly developing field in brachytherapy is the use of beta-ray sources for prevention of restenosis, i.e. re-closing of artery, following coronary and peripheral artery interventional procedures such as angioplasty, atherectomy and stent implantation. The dosimetry of beta-ray sources for therapeutic applications is particularly difficult due to the short distances involved, being at the millimeter range, and the high dose gradients at such short distances. Further difficulties are caused by the non-uniform distribution of activity in the source itself, causing a highly irregular dose distribution. The aim of this report is to recommend methods for calibration of low energy photon sources and beta-ray sources used in brachytherapy treatments and to propose suitable detectors for this purpose. Dose calculation methods are given both for the photon sources and beta-ray sources covered in this report. The present report has been developed in close collaboration with the ICRU Report Committee on this subject. The ICRU is planning to publish a report on the calibration of the type of sources discussed here. The present report is to a

  13. Design of a neutrino source based on beta beams

    Science.gov (United States)

    Wildner, E.; Hansen, C.; Benedetto, E.; Jensen, E.; Stora, T.; Mendonca, T. Melo; Vlachoudis, V.; Bouquerel, E.; Marie-Jeanne, M.; Balint, P.; Fourel, C.; Giraud, J.; Jacob, J.; Lamy, T.; Latrasse, L.; Sortais, P.; Thuillier, T.; Mitrofanov, S.; Loiselet, M.; Keutgen, Th.; Delbar, Th.; Debray, F.; Trophime, C.; Veys, S.; Daversin, C.; Zorin, V.; Izotov, I.; Skalyga, V.; Chancé, A.; Payet, J.; Burt, G.; Dexter, A. C.; Kravchuk, V. L.; Marchi, T.; Cinausero, M.; Gramegna, F.; De Angelis, G.; Prete, G.; Collazuol, G.; Mezzetto, M.; Vardaci, E.; Di Nitto, A.; Brondi, A.; La Rana, G.; Moro, R.; Palladino, V.; Gelli, N.; Mazzocco, M.; Signorini, C.; Hirsh, T. Y.; Hass, M.; Berkovits, D.; Stahl, A.; Schaumann, M.; Wehner, J.

    2014-07-01

    "Beta beams" produce collimated pure electron (anti)neutrino beams by accelerating beta active ions to high energies and having them decay in a racetrack shaped storage ring of 7 km circumference, the decay ring. EUROnu beta beams are based on CERN infrastructures and existing machines. Using existing machines may be an advantage for the cost evaluation, but will also constrain the physics performance. The isotope pair of choice for the beta beam is He6 and Ne18. However, before the EUROnu studies one of the required isotopes, Ne18, could not be produced in rates that satisfy the needs for physics of the beta beam. Therefore, studies of alternative beta emitters, Li8 and B8, with properties interesting for a beta beam have been proposed and have been studied within EUROnu. These alternative isotopes could be produced by using a small storage ring, in which the beam traverses a target, creating the Li8 and B8 isotopes. This production ring, the injection linac and the target system have been evaluated. Measurements of the cross section of the reactions to produce the beta beam isotopes show interesting results. A device to collect the produced isotopes from the target has been developed and tested. However, the yields of Li8 and B8, using the production ring for production of Li8 and B8, is not yet, according to simulations, giving the rates of isotopes that would be needed. Therefore, a new method of producing the Ne18 isotope has been developed and tested giving good production rates. A 60 GHz ECRIS prototype, the first in the world, was developed and tested for ion production with contributions from EUROnu. The decay ring lattices for the Li8 and B8 have been developed and the lattice for He6 and Ne18 has been optimized to ensure the high intensity ion beam stability.

  14. Sources of Alpha and Beta in Property Funds

    OpenAIRE

    Baum, Andrew; Farrelly, Kieran

    2008-01-01

    This paper examines issues related to potential analytical performance systems for global property funds. These will include traditional attribution methods but will also cover the performance concepts of alpha and beta widely used in other asset classes. We look at issues including...what creates beta, and what drives alpha in real estate investment? How can it be measured and isolated? How do these concepts relate to traditional attribution systems? Can performance records and performanc...

  15. 2$\\pi$ proportional counting chamber for large-area-coated $\\beta$ sources

    Indian Academy of Sciences (India)

    DESAI SHRADDHA S

    2016-06-01

    Detection system for measuring absolute emission rate from large-area-coated $\\beta$ sources has been indigenously developed. The system consists of a multiwire-based proportional counter with gas flow and a source mounted within the sensitive volume of the detector. Design of the counter enables efficient counting of emissions in $2\\pi$ solid angle.A provision is made for change ofthe source and immediate measurement of source activity. These sources are used to calibrate the efficiency of contamination monitors at radiological facilities. Sensitive area of the detector covers 165◦ solid angle nearing $2\\pi$ of emission from the source of size $100 \\times 150$ mm. Performance of the chamber is tested using collimated $^{55}$Fe X-ray source and $^{90}$Sr / $^{90}$Y coated $\\beta$ sources of various activities. The activity measurement system is established as a national primary standard for calibration of coated $\\beta$ sources at Radiological Laboratory at BARC. Design and performanceof the chamber are presented.

  16. Numerical calculation of relative dose rates from spherical 106Ru beta sources used in ophthalmic brachytherapy

    Directory of Open Access Journals (Sweden)

    Eduardo de Paiva

    2015-01-01

    Full Text Available Concave beta sources of 106Ru/106Rh are used in radiotherapy to treat ophthalmic tumors. However, a problem that arises is the difficult determination of absorbed dose distributions around such sources mainly because of the small range of the electrons and the steep dose gradients. In this sense, numerical methods have been developed to calculate the dose distributions around the beta applicators. In this work a simple code in Fortran language is developed to estimate the dose rates along the central axis of 106Ru/106Rh curved plaques by numerical integration of the beta point source function and results are compared with other calculated data.

  17. Numerical calculation of relative dose rates from spherical 106Ru beta sources used in ophthalmic brachytherapy

    Science.gov (United States)

    de Paiva, Eduardo

    Concave beta sources of 106Ru/106Rh are used in radiotherapy to treat ophthalmic tumors. However, a problem that arises is the difficult determination of absorbed dose distributions around such sources mainly because of the small range of the electrons and the steep dose gradients. In this sense, numerical methods have been developed to calculate the dose distributions around the beta applicators. In this work a simple code in Fortran language is developed to estimate the dose rates along the central axis of 106Ru/106Rh curved plaques by numerical integration of the beta point source function and results are compared with other calculated data.

  18. Measurement of the output of ISO recommended beta sources with an extrapolation chamber

    International Nuclear Information System (INIS)

    Output measurements in terms of absorbed dose rate to tissue were carried out for the ISO (International Organization for Standardization) recommended beta sources 90Sr/90Y, 85Kr and 147Pm using an extrapolation chamber. A holder made of anodized aluminium for the extrapolation chamber for the output measurements was designed indigenously. The measured dose rates for three beta sources were compared with the corresponding values provided in the certificate by the Physikalisch-Technische Bundesanstalt (PTB), the National Standard Laboratory of Germany. Depending upon the source and source-to-chamber distance, the PTB certificate values have uncertainties in the range ±1.2–±1.5%. The measured dose rates have uncertainties of about ±0.3%. The deviations between the measured dose rates and the PTB certificate values compare well (maximum deviation is about 2%) considering the combined uncertainties associated with the measurements and the certificate values. The study suggests that the beta irradiation system comprising the above beta sources can be utilized for quality assurance programme related to personnel monitoring services in India. - Highlights: • Absorbed dose rates to tissue were measured for 90Sr/90Y, 85Kr and 147Pm ISO recommended beta sources with extrapolation chamber. • A holder made of aluminium was designed indigenously for the extrapolation chamber. • The measured dose rates agree well with the values provided in the PTB certificate. • The study suggests beta sources can be utilized for QA programme in personnel monitoring services

  19. Preparation of high activity HTO using recovered tritium from expired beta light sources

    International Nuclear Information System (INIS)

    In this paper the technological procedures for treatment of expired beta light sources as radioactive wastes with tritium recovering and use in synthesis of high specific activity HTO were analyzed. Technological procedures for treatment of beta light sources consist in: envelope breaking into vacuumed enclosure, the radioactive gaseous mixture pumping and its storing onto metallic sodium. The obtained 3T2-3He mixture was used in the synthesis of HTO with high radioactivity concentration. (authors)

  20. Multiwire-based 2π proportional chamber for large area beta sources

    International Nuclear Information System (INIS)

    The proportional counter for surface emission counting of large-area beta sources is indigenously developed. The detector is multiwire-based proportional counter with gas flow facility and is designed for 2π mode counting of planar beta sources. The detector is rugged, stable and convenient to operate. Complete detector assembly consists of a vacuum tight aluminum enclosure, multiwire grid, sliding source tray, vacuum system, gas flow system and pulse processing units. Qualitative position dependent behavior of detector over the sensitive region is initially tested using a collimated 55Fe X-ray source. Characterization of the detector is carried out using 90Sr extended beta sources of various emission activities. These sources are further used to calibrate efficiency of radiological contamination monitors located at various nuclear facilities. Details of design, fabrication and characterization of the chamber are presented. (author)

  1. Automatic device for measuring {beta}-emitting sources: P.A.P.A. {beta}-meters; Dispositif automatique pour la mesure de sources emettrices de rayonnement {beta}: P.A.P.A. {beta} metres

    Energy Technology Data Exchange (ETDEWEB)

    Colomer, J.; Valentin, M. [Commissariat a l' Energie Atomique, Bruyeres-le-Chatel (France). Centre d' Etudes

    1969-07-01

    The apparatus described is designed for measuring {beta}-emitting elements by the absorption method; it is suitable for carrying out a large number of routine analyses. A mechanical device pushes an aluminium absorption set automatically between the source and the detector; the movement is programmed for cutting on and off by a transistorized electronic unit, with printing out and punching of the results on tape; then this can be mathematically processed by a computer (tracing of absorption spectra, extrapolation and calculation of the activity). The detector is either a {beta}-probe or a proportional counter with a specially designed loop. For routine measurements, the accuracy obtained, with all corrections made, is from 5 to 8 per cent; the reproducibility is about 2 per cent. (authors) [French] L'appareillage decrit est destine aux mesures des elements emetteurs {beta} par la methode d'absorption et il permet d'effectuer, en routine, un nombre important de mesures. Un ensemble mecanique effectue le passage automatique, sous vide primaire, d'un jeu d'absorption en aluminium entre la source et le detecteur, ce passage est programme en pre-temps ou pre-coup par un ensemble electronique a transistors, avec impression et perforation sur bandes des resultats des mesures pour traitement mathematique par un ordinateur (trace du spectre d'absorption, extrapolation et calcul d'activite). Le detecteur est soit une sonde {beta}, soit un compteur proportionnel a boucle specialement realise. Sur des mesures de routine, la precision obtenue, toutes corrections effectuees, est de 5 a 8 pour cent et la reproductibilite de l'ordre de 2 pour cent. (auteur)

  2. Factors affecting quality for beta dose rate measurements using ISO 6980 series I reference sources

    Energy Technology Data Exchange (ETDEWEB)

    Burns, R.E. Jr.; O`Brien, J.M. Jr. [Atlan-Tech, Rosewll, GA (United States)

    1993-12-31

    Atlan-Tech, Inc. has performed several calibrations of ISO 6980 Series 1 reference beta sources over the past two to three years. There were many problems encountered in attempting to compare the results of these calibrations with those from other laboratories, indicating the need for more standardization in the methodology employed for the measurement of the absorbed dose rate from ISO 6980 Series 1 reference beta sources. This document describes some of the problems encountered in attempting to intercompare results of beta dose-rate measurements. It proposes some solutions in an attempt to open a dialogue among facilities using reference beta standards for the purpose of promoting better measurement quality assurance through data intercomparison.

  3. Synthesis of Estradiol-T-G using recovered tritium from expired Beta Light sources

    International Nuclear Information System (INIS)

    Full text: After about 10 years by utilisation, the Beta Light sources loss 75% luminescence and their replacement is required. The storage of expired sources as radioactive wastes is not recommended due to the fragility of their glass envelope and to the gaseous state of the radioactive material at high pressure. In this paper we analysed a technological modalities for Beta Light sources treatment as radioactive wastes with tritium recovering and its use in synthesis of tritiated Estradiol by isotopic exchange technique. The effect of 3He presence was analysed. (authors)

  4. Characterization of large-area reference sources for the calibration of beta-contamination monitors

    Science.gov (United States)

    Janßen, H.; Klein, R.

    1996-02-01

    A method has been developed whereby the activity of a large-area reference source for the calibration of beta-contamination monitors can be determined from a series of measured countrates in a suitable detection system as a function of the distance between the surface of the source and the front face of the detector.

  5. Effects of purified dietary fiber sources on beta-carotene utilization by the chick.

    Science.gov (United States)

    Erdman, J W; Fahey, G C; White, C B

    1986-12-01

    Effects of various purified dietary fiber components on beta-carotene utilization by the chick were investigated in two experiments (expt.). Eight-day-old Columbian X New Hampshire male (expt. 1) or female (expt. 2) chicks were fed a vitamin A-deficient diet for 1 wk and then fed beta-carotene-supplemented diets containing 0% fiber, 7% arenaceous flour or 7% of a purified fiber source for 4 wk. Results of expt. 1 showed that hemicellulose, lignin and citrus pectin, but not arenaceous flour or polygalacturonic acid, depressed beta-carotene utilization by the chick, as measured by percentage of consumed beta-carotene stored in liver as vitamin A relative to the 0% fiber control. In expt. 2, effects of the methoxyl content of pectin were studied. High and medium methoxyl apple pectin, citrus pectin and polygalacturonic acid reduced storage of vitamin A in liver. Low methoxyl apple pectin had no significant effect on beta-carotene utilization. Thus, several purified forms of dietary fiber significantly reduced beta-carotene utilization by chicks when fed at the 7% supplementary level. Moreover, with pectin, there was an inverse relationship between methoxyl content of pectin and beta-carotene utilization. PMID:3027282

  6. Prospects for Detecting a Neutrino Magnetic Moment with a Tritium Source and Beta-beams

    OpenAIRE

    McLaughlin, G. C.; Volpe, C.

    2003-01-01

    We compare the prospects for detecting a neutrino magnetic moment by the measurement of neutrinos from a tritium source, reactors and low-energy beta-beams. In all cases the neutrinos or antineutrinos are detected by scattering of electrons. We find that a large (20 MCurie) tritium source could improve the limit on the neutrino magnetic moment significantly, down to the level of a few $\\times 10^{-12}$ while low-energy beta-beams with sufficiently rapid production of ions could improve the li...

  7. Synthesis of labeled compounds using recovered tritium from expired beta light sources

    International Nuclear Information System (INIS)

    In this paper, the technological procedures for extracting tritium from beta light source are highlighted. The recovered tritium was used in the synthesis of organically labeled compounds and in the preparation of tritiated water (HTO) with high specific activity. Technological procedures for treatment of beta light sources consist of: envelope breaking into evacuated enclosure, the radioactive gaseous mixture pumping and its storage on metallic sodium. The mixtures of T2 and 3He were used in the synthesis of tritium labeled steroid hormones, nucleosides analogues and for the preparation of HTO with high radioactivity concentrations. (authors)

  8. Elaboration of supports for beta emitting sources (with vyns)

    International Nuclear Information System (INIS)

    The Laboratory of Radioactive patterns account with a 4 πβ-γ coincidence system of recent acquisition with which absolute measures of radioactive activity with uncertainties of the order of 0.1% can be made. Since the coincidence method for the activity measure consists on detecting to the particle and the photon corresponding to oneself nuclear disintegration, it is necessary to elaborate special radioactive sources on thin supports, in order to allowing the maximum possible fluence of β particles (∼ 100%). This work a technique for the elaboration of these sources and for the measure of the thickness of the walls of the support is presented. (Author)

  9. A novel method for the activity measurement of large-area beta reference sources.

    Science.gov (United States)

    Stanga, D; De Felice, P; Keightley, J; Capogni, M; Ioan, M R

    2016-03-01

    A novel method has been developed for the activity measurement of large-area beta reference sources. It makes use of two emission rate measurements and is based on the weak dependence between the source activity and the activity distribution for a given value of transmission coefficient. The method was checked experimentally by measuring the activity of two ((60)Co and (137)Cs) large-area reference sources constructed from anodized aluminum foils. Measurement results were compared with the activity values measured by gamma spectrometry. For each source, they agree within one standard uncertainty and also agree within the same limits with the certified values of the source activity. PMID:26701656

  10. Use of gaseous tritium light sources (Beta lights) with respect to nocturnal illumination

    International Nuclear Information System (INIS)

    A number/letter plate for use in, for example darkened buildings has spaced apart gaseous tritium light sources (beta lights) arranged centrally along the indicia on a reflective background sealed in clear translucent plastics. Uses include house numbers, name plates, telephone numbers, notices, product advertisements, vehicle registration plates and names or trade marks on products. (author)

  11. Interlaboratory beta source calibration using TL and OSL on natural quartz

    DEFF Research Database (Denmark)

    Goksu. H.Y.; Bailiff, I.K.; Bøtter-Jensen, L.;

    1995-01-01

    Laboratory at GSF using a Go-60 source as well as the in situ measurements with an ionization chamber, calibrated to the primary standards of PTB Braunschweig. Irradiated and unirradiated quartz was distributed to the five laboratories and although different procedures were used for thermoluminescence and......Laboratories using luminescence methods for dose reconstruction have to make interlaboratory source calibrations-initially this will be a single isotope beta or gamma source using one particular reference material. The procedure requires not only the administration of exact doses to the material...... but also the uniform handling of the dosimetric material and standardization of the procedures. An interlaboratory calibration of an Sr-90 beta source was recently carried out by our five laboratories which are involved in a retrospective project. The reference material was quartz but there were...

  12. Numerical modeling of large-area beta sources constructed from anodized-aluminum foils

    International Nuclear Information System (INIS)

    The numerical modeling of large-area beta sources constructed from anodized-aluminum foils is described in this paper. Based on a realistic model for the activity depth distribution, theoretical lower and upper bounds for the efficiency and the transmission coefficient were calculated and used to analyze the comparison method recommended by ISO 8769 for measuring the surface emission rate. The analysis shows that this method can provide measurement results with relative standard uncertainties smaller than 3% for high energy beta emitters such as 90Sr–90Y, 36Cl and 204Tl.

  13. An advanced method of activity determination of large area beta emitting sources

    International Nuclear Information System (INIS)

    The presented advanced method of activity determination of large area beta emitting sources is based on a version of efficiency tracing method using a test foil placed between the source and a conventional large area detector. It is shown that the total efficiency of the measuring system may depend on a dimensionless parameter derived from the difference in count rates caused by inserting the test foil while other disturbing effects are mostly reduced or compensated. - Highlights: • Efficiency tracing transmission method of beta activity determination. • Efficiency determined by means of a parameter independent of initial absorption conditions. • Parameter is derived from two counting results obtained with using a test foil. • Particularly useful for calibration and measurement of radionuclide standard sources

  14. Design and characteristics of beta-excited X-ray sources

    International Nuclear Information System (INIS)

    The paper reports on recent work on beta-excited X-ray sources. Results of detailed experimental investigation on the X-rays produced by the fission products Pm147, Kr85 and Sr90 are described. X-ray yields and spectral distributions have been studied for target materials ranging from copper to uranium and in a variety of source-target geometries (transmission target, reflection target, sandwich target, intimate source-target mixtures). To interpret the experimental results, an analytical treatment of the processes involved in X-ray production by beta particles has been developed and is outlined. By taking into account bremsstrahlung, K-shell ionization, and fluorescent X-ray excitation, a convenient mathematical formulation may be derived for photon spectra and yields as functions of maximum β-energy, target thickness and source configuration. The agreement between calculated and experimentally determined yields is excellent and confirms the merit of the analysis. It thus becomes possible to optimize the design of isotopic X-ray sources for specific applications. Kr85 and Pm147 prototype sources have been designed and 'their performance in thickness and composition-analysis measurements is discussed. A high level Pm147 source for industrial radiography has also been designed and its performance, along with the utility of image intensifiers to extend its applicability, is considered. Finally, a general review of potentialities, advantages and limitations of isotopic X-ray sources is given. (author)

  15. Accurate measurements of surface emission rate for large-area alpha and beta reference sources

    International Nuclear Information System (INIS)

    For alpha emitters and beta emitters with maximum beta energy greater than 0.150 MeV, the characteristics of reference sources for the calibration of surface contamination monitors are specified by the international standard ISO 8769. According to this standard, the surface emission rate of reference sources has to be measured by absolute methods or by using an instrument that has been calibrated by means of sources that has been measured absolutely. Moreover, the surface emission rate has to be measured by the national standards laboratory with an uncertainty which must not exceed 3% (one standard deviation). In this paper, the counting system and the experimental conditions needed for accurate measurements of the surface emission rate are presented. The uncertainty of such measurements is much smaller than 3%. The evaluation of this uncertainty is also described. The counting system used for absolute alpha and beta surface emission rate measurements is composed of a large area, gas-flow, windowless proportional detector, an integral and a spectrometric counting channels. The method of measurement for alpha and beta surface emission rate is very simple but it is necessary to achieve the optimum experimental conditions of counting for obtaining accurate measurement results. Thus, the proportional detector has to work under a continuous and stable gas-flow and its plateau has to be long with a very low slope. To obtain a counting efficiency of 100%, it has to use a tight detector and a very pure counting gas. Additionally, the detector must be flushed and then operated under a steady gas-flow for several hours prior to measurements in order to be cleaned of air impurities. To perform alpha and beta surface emission rate measurements we optimized first the conditions of counting. For beta sources, the discrimination level has been adjusted by means of a 55 Fe source. Using this spectrum, we checked the stability of the counting system because the peak, corresponding

  16. Analytical approximation of the dose distribution from point beta-sources

    International Nuclear Information System (INIS)

    A new method for analytical calculation of the beta-ray dose from point sources which accounts for the total beta-spectrum shape are presented and the results are compared to calculations of Loevinger and the Monte-Carlo groups. The most important feature is that it can be used for the resultant sum of several spectra and also for distorted or experimentally measured spectra. The method uses tabulated values for the specific energy lost and calculated or measured values for the shape of the total spectrum from nuclide or mixture of nuclides. The approach have been tested with isotopes with different beta-ray shapes(90Sr, 90Y) and in the presence of conversion electrons - 137Cs. 106Rh is included because of high Emax = 3.54 MeV. The agreement of the proposed method with the Monte-Carlo simulations is very good. The chosen spectra are with very different initial shape, which confirms the applicability of the approach. The major deviation is for the large distances due to the limited accuracy of the Loevinger method. The approach can be used for the soft biological tissue and for other than point sources. For the skin contamination it is necessary the backscattering electrons to be taken into account. An initial version of the approach has been used for calculations of beta-ray doses due to hot particles after the Chernobyl accident

  17. Prospects for Detecting a Neutrino Magnetic Moment with a Tritium Source and Beta-beams

    CERN Document Server

    McLaughlin, G C

    2003-01-01

    We compare the prospects for detecting a neutrino magnetic moment by the measurement of neutrinos from a tritium source, reactors and low-energy beta-beams. In all cases the neutrinos or antineutrinos are detected by scattering of electrons. We find that a large (20 MCurie) tritium source could improve the limit on the neutrino magnetic moment significantly, down to the level of a few $\\times 10^{-12}$ while low-energy beta-beams with sufficiently rapid production of ions could improve the limits to the level of a few $\\times 10^{-11}$. The latter would require ion production at the rate of at least $10^{15}$ s$^{-1}$.

  18. Spatial analysis and source profiling of beta-agonists and sulfonamides in Langat River basin, Malaysia.

    Science.gov (United States)

    Sakai, Nobumitsu; Yusof, Roslan Mohd; Sapar, Marni; Yoneda, Minoru; Mohd, Mustafa Ali

    2016-04-01

    Beta-agonists and sulfonamides are widely used for treating both humans and livestock for bronchial and cardiac problems, infectious disease and even as growth promoters. There are concerns about their potential environmental impacts, such as producing drug resistance in bacteria. This study focused on their spatial distribution in surface water and the identification of pollution sources in the Langat River basin, which is one of the most urbanized watersheds in Malaysia. Fourteen beta-agonists and 12 sulfonamides were quantitatively analyzed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). A geographic information system (GIS) was used to visualize catchment areas of the sampling points, and source profiling was conducted to identify the pollution sources based on a correlation between a daily pollutant load of the detected contaminant and an estimated density of human or livestock population in the catchment areas. As a result, 6 compounds (salbutamol, sulfadiazine, sulfapyridine, sulfamethazine, sulfadimethoxine and sulfamethoxazole) were widely detected in mid catchment areas towards estuary. The source profiling indicated that the pollution sources of salbutamol and sulfamethoxazole were from sewage, while sulfadiazine was from effluents of cattle, goat and sheep farms. Thus, this combination method of quantitative and spatial analysis clarified the spatial distribution of these drugs and assisted for identifying the pollution sources. PMID:26799806

  19. Radioactivity Determination of Sealed Beta-Emitting Sources by Surface Dose Measurements and Monte Carlo Simulations

    International Nuclear Information System (INIS)

    The four primary radiation measurement systems considered to be necessary for the modern radionuclide measurement laboratory are gas-flow proportional counters, liquid scintillation counters, Si spectrometer systems, and Ge spectrometer systems. A national institute of standards recognized by BIPM (Bureau International des Poids et Mesures) use these measurement systems have some limitation. For a gas-filled detector, the source size should not be larger than that determined by the counter geometry and the measurements are limited to sources with the activities of less than 20,000 Bq. A liquid scintillation detector can only be used to measure an activity of liquid mixture isotope. Therefore it can't be used to measure activities of sealed sources. Further it is quite difficult to measure a radioactivity of beta-isotope accurately due to self-absorption and scattering. In particular an radioactivity generated by a nuclear reactor is approximately calculated by using target material compositions, cross-sections, and neutron flux, which the nuclear reactor. However, the results from this approach involve a high uncertainty. We develop a Monte Carlo applied radioactivity determination for beta sources. The extrapolation ion-chamber was used to measure the surface dose rate for a standard source. The Sr/Y-90 standard source is calibrated by NIST used for this study. There was about 1.7% difference in the reference dose rates measured by the two techniques. These difference and relative errors were comparable to those of other studies. It should be noticed that the area of collecting electrode was nine times larger than that of radiation field. It the diameter of the source is smaller than the area of collecting electrode, the source should be located at a sufficiently large distance from the detector surface so that the radiation field at the detector surface was larger than the area of collecting electrode. In addition, beta particles from the applicator interact

  20. Determination of the dose rapidity of a 90 Sr beta radiation source using thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    The thermoluminescent dosemeters developed in Mexico, have been used efficiently in environmental and personal dosimetry. When the dose rate of some source is not known can be estimated with the use of thermoluminescent dosemeters taking in account the geometrical array used in the irradiations for reproducibility of the results in posterior irradiations. In this work it was estimated the dose rate of a 90 Sr-90 Y beta radiation source which is property of the Nuclear Sciences Institute, UNAM, therefore it was l ended to the Metropolitan Autonomous University- Iztapalapa Unit for the characterization of new Tl materials, taking account of the institutional collaboration agreements. (Author)

  1. Extrapolation ionisation chamber measurements on beta-emitting sources produced for the CEGB collaborative radiobiology programme

    International Nuclear Information System (INIS)

    This report describes the structure and application of an extrapolation ionisation chamber used for measuring dose-rates from plane and point beta-emitting sources. These measurements form the basis of the dosimetry for a collaborative radiobiological study of skin to study both stochastic and non-stochastic effects. A small sample from the wide range of measurements undertaken in the programme has been selected to illustrate the procedures involved. The extrapolation chamber is currently being automated and it is intended that this report should provide a source reference to the basis of the measurements made between 1977-86. (author)

  2. Standardization of large area alpha and beta sources with a windowless multi-wire proportional counter

    International Nuclear Information System (INIS)

    A measurement system was assembled and tested for the absolute standardization of large area alpha and beta sources. Such sources are employed to calibrate a variety of contaminometers. A window-less multi-wire proportional counter, donation of the Laboratoire National Henri Becquerel (LNHB), Saclay - France, was used, with pure methane as flowing gas. The needed electronics (high voltage, amplifier, discriminator, counter, clock, MCA) was a CANBERRA one. Point and extended sources of 241 Am, 90 Sr + 90 Y and 204 Tl were standardized. The variation of the counting rate with high voltage provided a 'plateau' at (300-500) V, with a slope of (0.1-1.5)% for 100 V. The efficiency of the counter for a point beta source and a central area of (100x150) mm2, varied with less than 0.2%. To avoid spurious pulses, adequate threshold and working high voltage were chosen, and an imposed 10 ms dead-time was inserted in the counting channel. A procedure for the threshold correction was established. A compound uncertainty of maximum 2% was obtained, a quite acceptable value for extended sources. These results, together with the results obtained at LNHB with an identical counter, but using argon/methane mixture, will be presented at the 2001 Symposium of ICRM (International Committee for Radionuclide Metrology) in Germany. (authors)

  3. Standardization of a large area alpha and beta sources with a windowless multiwire proportional counter

    International Nuclear Information System (INIS)

    In The Radionuclide Metrology Group of IFIN-HH, a measurement system was assembled and tested for the absolute standardization of large area alpha and beta sources. Such sources are employed to calibrate a variety of contaminometers. A windowless multi-wire proportional counter, a donation of the 'Laboratoire National Henri Becquerel' (LNHB), Saclay-France, was used, with pure methane as flowing gas. The needed electronics (high voltage supply, amplifier, discriminator, counter, clock, MCA) was a CANBERRA one. Point and extended sources of 241 Am, 90 (Sr+Y) and 204 Tl were standardized. The variation of the counting rate with high voltage provided 'plateaus' of (300-500) V, with a slope of (0.1-1.5)% for 100 V. The efficiency of the counter for a point beta source and a central area of (100 x 150) mm2, varied with less than 0.2%. To avoid spurious pulses, adequate threshold and working high voltage were chosen, and an imposed 10 μs dead-time was inserted in the counting channel. A procedure for the threshold correction was established. A combined uncertainty of maximum ± 2% was obtained, a quite acceptable value for extended sources. These results, together with the results obtained by Romanian specialists in LNHB, with an identical counter, but using argon/methane mixture will be published. The experiment was realised in the frame of the IFIN-HH long term collaboration agreement. (authors)

  4. Sources of beta diversity in estuarine benthic macro-invertebrate communities in the Baltic Sea - North Sea transition

    DEFF Research Database (Denmark)

    Josefson, Alf B.; Göke, Cordula

    Identification of sources of beta diversity, the change of diversity, is important to understand regulation of overall diversity. Additive partitioning of diversity (species richness and expH) compared to random, was performed on a quantitative benthic macro-invertebrate collection of > 400 species...... regions. The study indicates control of beta diversity by both environmental factors and factors related to invertebrate biology, operating at different spatial scales....... regimes (ca 100 km). Contributions of beta to total diversity were high among regions, but minor between sediment types. Thus controlling for the two environmental factors, salinity and sediment type, there was still an unexplained high beta among stations within regions. A significant distance...

  5. Radioactivity determination of sealed pure beta-sources by surface dose measurements and Monte Carlo simulations

    Science.gov (United States)

    Choi, Chang Heon; Jung, Seongmoon; Choi, Kanghyuk; Son, Kwang-Jae; Lee, Jun Sig; Ye, Sung-Joon

    2016-04-01

    This study aims to determine the activity of a sealed pure beta-source by measuring the surface dose rate using an extrapolation chamber. A conversion factor (cGy s-1 Bq-1), which was defined as the ratio of surface dose rate to activity, can be calculated by Monte Carlo simulations of the extrapolation chamber measurement. To validate this hypothesis the certified activities of two standard pure beta-sources of Sr/Y-90 and Si/P-32 were compared with those determined by this method. In addition, a sealed test source of Sr/Y-90 was manufactured by the HANARO reactor group of KAERI (Korea Atomic Energy Research Institute) and used to further validate this method. The measured surface dose rates of the Sr/Y-90 and Si/P-32 standard sources were 4.615×10-5 cGy s-1 and 2.259×10-5 cGy s-1, respectively. The calculated conversion factors of the two sources were 1.213×10-8 cGy s-1 Bq-1 and 1.071×10-8 cGy s-1 Bq-1, respectively. Therefore, the activity of the standard Sr/Y-90 source was determined to be 3.995 kBq, which was 2.0% less than the certified value (4.077 kBq). For Si/P-32 the determined activity was 2.102 kBq, which was 6.6% larger than the certified activity (1.971 kBq). The activity of the Sr/Y-90 test source was determined to be 4.166 kBq, while the apparent activity reported by KAERI was 5.803 kBq. This large difference might be due to evaporation and diffusion of the source liquid during preparation and uncertainty in the amount of weighed aliquot of source liquid. The overall uncertainty involved in this method was determined to be 7.3%. We demonstrated that the activity of a sealed pure beta-source could be conveniently determined by complementary combination of measuring the surface dose rate and Monte Carlo simulations.

  6. A comparison of intravascular source designs based on the beta particle emitter 114mIn/114In Line source versus stepping source

    International Nuclear Information System (INIS)

    Background: Catheter-based intravascular brachytherapy (IVB) sources of the next generation will have to meet high demands in terms of miniaturization, flexibility, safety, reliability, costs and versatility. The radionuclide pair 114mIn/114In (half-life 49.51 days, maximum beta energy 2.0 MeV, average beta energy 0.78 MeV) is an attractive beta emitter for application in such a source. Methods: Since metallic indium is unfit for the manufacture of a brachytherapy source, the feasibility, safety and dosimetric properties of a design concept comprising a linear array of ceramic In2O3 spheres within a thin-walled, superelastic Ni/Ti capsule are investigated. Results: Neutron activation of enriched In2O3 spheres yields a specific activity sufficiently high for the manufacture of a stepping source, keeping treatment times limited to a few minutes. Although 114mIn/114In also emits some gamma radiation, the effective doses received by members of the medical staff are an order of magnitude lower than those received from fluoroscopy. The dose distributions about a 40-mm line source and a 5-mm stepping source (outer diameter 0.36 mm) are calculated using MCNP4C. Dose-volume histograms (DVHs) are calculated for the line source (centered and noncentered) and the stepping source (centered) using the geometry of a human coronary artery. Conclusion: The results show that a centered stepping source with optimized dwell times delivers the most homogenous dose within the target volume

  7. A new technique for making large area beta reference sources required for calibration of surface contamination monitors

    International Nuclear Information System (INIS)

    A new technique has been developed for making large area reference beta sources required for the calibration of beta contamination monitors. Two 13 x 33 cm2 of 90Sr/90Y sources of surface activity 4-5 Bq/cm2 were prepared for testing of a typical large area contamination monitor developed by RSSD, BARC. Two 10 x 15 cm2 of 90Sr/90Y sources were also prepared as per ISO 8769. Surface non-uniformity of these sources was measured with the help of a specially designed jig. The non-uniformity in these sources was measured to be 15%. (author)

  8. Calibration System for Dosimetry and Radioactivity of Beta-Emitting Sources

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Chang Heon; Ye, Sungjoon [Seoul National Univ., Seoul (Korea, Republic of); Son, Kwangjae; Park, Uljae [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-07-01

    This study aims to develop a calibration system for radioactivity of beta sources using a calibration constant which derived from comparing measurement and simulation. It is hard to measure the activity of beta emitter isotope due to self absorption and scattering. So the activity involves high levels of uncertainty. The surface dose of Sr/Y-90 standard isotope was measured using extrapolation chamber and calculated using Monte Carlo. The activity (4.077 kBq) of source was measured by NIST measurement assurance program. And several correction factors were calculated Monte Carlo method. The measurement result was corrected by correction factors. The calibration constant was defined as the ratio of surface dose to activity. It was 4.5Χ10{sup -8} and 6.52Χ10{sup -8} for measurement and Monte Carlo, respectively. There was about 15.4% difference in the calibration constant determined by the two techniques. The depth uncertainty makes the difference because of high dose gradients. Some correction factors have error due to scattering by detector geometry. A test source will be produced by HANARO. The activity will be calculated using calibration constant. The activity will be performed cross-calibration with NIST. Finally, the system will provide accurate information of sources.

  9. Response-surface models for deterministic effects of localized irradiation of the skin by discrete {beta}/{gamma} -emitting sources

    Energy Technology Data Exchange (ETDEWEB)

    Scott, B.R.

    1995-12-01

    Individuals who work at nuclear reactor facilities can be at risk for deterministic effects in the skin from exposure to discrete {Beta}- and {gamma}-emitting ({Beta}{gamma}E) sources (e.g., {Beta}{gamma}E hot particles) on the skin or clothing. Deterministic effects are non-cancer effects that have a threshold and increase in severity as dose increases (e.g., ulcer in skin). Hot {Beta}{gamma}E particles are {sup 60}Co- or nuclear fuel-derived particles with diameters > 10 {mu}m and < 3 mm and contain at least 3.7 kBq (0.1 {mu}Ci) of radioactivity. For such {Beta}{gamma}E sources on the skin, it is the beta component of the dose that is most important. To develop exposure limitation systems that adequately control exposure of workers to discrete {Beta}{gamma}E sources, models are needed for systems that adequately control exposure of workers to discrete {Beta}{gamma}E sources, models are needed for evaluating the risk of deterministic effects of localized {Beta} irradiation of the skin. The purpose of this study was to develop dose-rate and irradiated-area dependent, response-surface models for evaluating risks of significant deterministic effects of localized irradiation of the skin by discrete {Beta}{gamma}E sources and to use modeling results to recommend approaches to limiting occupational exposure to such sources. The significance of the research results as follows: (1) response-surface models are now available for evaluating the risk of specific deterministic effects of localized irradiation of the skin; (2) modeling results have been used to recommend approaches to limiting occupational exposure of workers to {Beta} radiation from {Beta}{gamma}E sources on the skin or on clothing; and (3) the generic irradiated-volume, weighting-factor approach to limiting exposure can be applied to other organs including the eye, the ear, and organs of the respiratory or gastrointestinal tract and can be used for both deterministic and stochastic effects.

  10. Development of A phantom for ophthalmic beta source applicator quality control using TL dosimetry

    Science.gov (United States)

    Barbosa, N. A.; da Rosa, L. A. R.; Braz, D.

    2015-11-01

    Concave eye applicators with 90Sr/90Y and 106Ru/106Rh beta ray sources are usually used in brachytherapy for the treatment of superficial intraocular tumors as uveal melanoma with thickness up to 5 mm. The calculation of the dose delivered to the eye is carried out based on the data present in the beta source calibration certificate. Therefore, it would be interesting to have a system that could evaluate that dose. In this work, an eye phantom to be used with 106Ru/106Rh betatherapy applicators was developed in solid water. This phantom can hold nine micro-cube thermoluminescent (TL) dosimeters, TLD-100. The characteristics of the TL response of the dosimeters, namely reproducibility and individual sensitivity, were determined for a 60Co source. Using Monte Carlo code MCNPX, the dose to a water eye was determined at different depths. Exposing the eye phantom with TL dosimeters to the 106Ru/106Rh applicator, it is possible to assess calibration factors using the dose values obtained by Monte Carlo simulation to each depth. Using mean calibration factors, dose values obtained by TL dosimetry were compared to the data present in the applicators certificate. Mean differences for both applicators were lower than ±10%, maximum value 17% and minimum value 0.08%. Considering that the certificate values present an uncertainty of ±20%, the calibration procedure and the developed phantom are validated and can be applied.

  11. A simple method for determining the activity of large-area beta sources constructed from anodized aluminum foils

    International Nuclear Information System (INIS)

    A simple method has been developed for determining the activity of large-area beta reference sources in anodized aluminum foils. It is based on the modeling of the transmission of beta rays through thin foils in planar geometry using Monte Carlo simulation. The method was checked experimentally and measurement results show that the activity of large-area beta reference sources in anodized aluminum foils can be measured with standard uncertainties smaller than the limit of 10% required by ISO 8769. - Highlights: • A method for determining the activity of large-area beta sources is presented. • The method is based on a model of electron transport in planar geometry. • The method makes use of linear programming for determining the activity. • The uncertainty of the method is smaller than 10%

  12. Electrodeposition Techniques for the Preparation of Beta-Sprectroscopy Sources of Rare-Earth Elements

    DEFF Research Database (Denmark)

    Hansen, P. Gregers; Høgh, J.; Nielsen, H. L.

    1964-01-01

    Thin, uniform radioactive deposits of rare earths and related elements can be prepared by cathodic electrodeposition of their hydroxides. The main theoretical and experimental features of this process are reviewed and plating cell design and the choice of conditions are described together with the...... associated radio-chemical methods. The use of copper-backed nickel films is shown to allow the preparation of beta sources on quite thin (down to 45 μg cm−2) backings, if the copper layer is etched selectively after the radioactivity has been plated onto the nickel....

  13. Adult Pancreatic Alpha-Cells: A New Source of Cells for Beta-Cell Regeneration

    OpenAIRE

    Chung, Cheng-Ho; Levine, Fred

    2010-01-01

    Beta-cell deficit is the major pathological feature in type 1 and type 2 diabetes patients, and plays a key role in disease progression. In principle, beta-cell regeneration can occur by replication of pre-existing beta-cells, or by beta-cell neogenesis from stem/progenitors. Unfortunately, beta-cell replication is limited by the almost complete absence of beta-cells in patients with type 1 diabetes, and the increasing recognition that the beta-cell replicative capacity declines severely with...

  14. Characterisation of the radiation fields of beta secondary standards with extended area sources

    International Nuclear Information System (INIS)

    A new irradiation facility including beta secondary standards 147Pm and 204Tl has been established at the CEA-Fontenay aux Roses (IPSN-DPHD-SDOS). According to the recommendations of the ISO Standard 6980, for Series II sources, the available radiation fields can be used with or without flattening filters. In the latter case, irradiation of dosemeters can be performed closer to the source in order to take advantage of higher dose rates, but the characteristics of the radiation fields have to be determined for several distances from the source. Using a computer controlled extrapolation chamber, calibrations in terms of the quantity Hs(0.07; α) have been performed. Furthermore the homogeneity of the field has been determined for several points of calibration. Procedures for deriving the value of the calibration quantity have been carefully considered and an extensive analysis of the uncertainties involved at the different steps of the data treatment has been performed. A first series of results are presented for 204Tl. Similar measurements for 147Pm are in progress, complemented by intercomparisons with reference sources of other laboratories. (author)

  15. Monte Carlo dosimetry for beta source selection and design for endovascular irradiation

    International Nuclear Information System (INIS)

    Purpose/Objective: Low dose irradiation is emerging as an exciting and promising new treatment modality for the prevention of vessel restenosis, which occurs in about 40% of the percutaneous transluminal angioplasty cases. The most challenging aspect of this new vessel irradiation modality is the determination of an effective target dose, and selection of an optimal source and delivery system. There is still much work to be done in the areas of radiobiological mechanisms, optimal source selection and design, optimal delivery system design, and precise dosimetric evaluation. This particular study was undertaken to use Monte Carlo techniques to examine and compare dose characteristics of two different beta sources (P-32 and Sr-90/Y-90), and to examine the dosimetric effects of source design considerations and vessel heterogeneities, i.e. calcification buildup. Materials and Methods: All our dose calculations were made using the MCNP4A code (Monte Carlo N-Particle, version 4A). This code was originally developed at Los Alamos National Laboratory and is capable of simulating coupled neutron-photon-electron problems using a three dimensional geometry modeling package. To validate our code, we compared point dose distributions for P32 and Sr90/Y90 with published data. We also compared our Monte Carlo calculations with physical measurements made with LiF TLDs about a custom made P-32 source sealed in the end of a flexible NiTi wire. We precisely modeled the source, the detectors, and the phantom material for our calculations. Once validated, we used both conventional and lattice tally geometries to examine two dimensional dosimetric effects resulting from design considerations such as: source selection (P32 verses Sr90/Y90); source length (3mm verses 10mm); source encapsulation materials (NiTi verses Stainless Steel); and catheter material composition (Nylon12, Nylon12 with BaSO4, and PVC) and thicknesses (0.15, 1, and 2 mm), and centering balloon design. We are also

  16. A new mini-extrapolation chamber for beta source uniformity measurements

    International Nuclear Information System (INIS)

    According to recent international recommendations, beta particle sources should be specified in terms of absorbed dose rates to water at the reference point. However, because of the clinical use of these sources, additional information should be supplied in the calibration reports. This additional information include the source uniformity. A new small volume extrapolation chamber was designed and constructed at the Calibration Laboratory at Instituto de Pesquisas Energeticas e Nucleares, IPEN, Brazil, for the calibration of 90Sr+90Y ophthalmic plaques. This chamber can be used as a primary standard for the calibration of this type of source. Recent additional studies showed the feasibility of the utilization of this chamber to perform source uniformity measurements. Because of the small effective electrode area, it is possible to perform independent measurements by varying the chamber position by small steps. The aim of the present work was to study the uniformity of a 90Sr+90Y plane ophthalmic plaque utilizing the mini extrapolation chamber developed at IPEN. The uniformity measurements were performed by varying the chamber position by steps of 2 mm in the source central axis (x-and y-directions) and by varying the chamber position off-axis by 3 mm steps. The results obtained showed that this small volume chamber can be used for this purpose with a great advantage: it is a direct method, being unnecessary a previously calibration of the measurement device in relation to a reference instrument, and it provides real -time results, reducing the time necessary for the study and the determination of the uncertainties related to the measurements. (authors)

  17. Tests of MVD prototype pad detector with a beta sup - source

    CERN Document Server

    Yeol-Kim, S; SuRyu, S; Hwan-Kang, J; Simon-Gillo, J; Sullivan, J P; Heck, H W V; Xu Guang Hu

    1999-01-01

    The MVD group has been testing two versions of silicon pad detectors. One design uses a single metal layer for readout trace routing. The second type uses two layers of metal, allowing for greatly simplified signal routing. However, because the readout traces for the pads pass over the other pads in the same column (separated by an oxide layer), the double-metal design introduces crosstalk into the system. A simple test stand using a sup 9 sup 0 Sr beta sup - source with scintillator triggers was made to estimate the crosstalk. The crosstalk between pads in the same column of the pad detector was 1.6-3.1%. The values measured between pads in different columns were very close to zero. The measured crosstalk was below our maximum allowed value of 7.8%.

  18. A new method for determining the efficiency of large-area beta sources constructed from anodized aluminum foils

    International Nuclear Information System (INIS)

    A new method has been developed for determining the efficiency of large-area beta sources in anodized aluminum foils using transmission measurements. The method was applied to the efficiency measurement of a 90Sr-90Y large-area reference source. Measurement results show that the method can provide efficiency values for 90Sr-90Y reference sources with standard uncertainties smaller than 2.9%, which are far below the limit of 10% required by ISO 8769.

  19. A new method for determining the efficiency of large-area beta sources constructed from anodized aluminum foils.

    Science.gov (United States)

    Stanga, D; Maringer, F J; Ionescu, E

    2011-01-01

    A new method has been developed for determining the efficiency of large-area beta sources in anodized aluminum foils using transmission measurements. The method was applied to the efficiency measurement of a (90)Sr-(90)Y large-area reference source. Measurement results show that the method can provide efficiency values for (90)Sr-(90)Y reference sources with standard uncertainties smaller than 2.9%, which are far below the limit of 10% required by ISO 8769. PMID:20817476

  20. Determination of half-value thickness of aluminum foils for different beta sources by using fractional calculus

    International Nuclear Information System (INIS)

    Reduction of beta-ray intensity with respect to thickness of absorber material exhibits a non-exponential behavior due to the different types of the energy loss processes and many different fractal-like paths followed by beta particles in material. According to Caputo formalism of fractional calculus, the reduction process of beta-ray intensity is governed by using a simple fractional differential equation of order α ≈ 0.31. The solution is obtained in terms of Mittag–Leffler function which depends on a mass attenuation coefficient μm and a fractional order α that can be considered as a measure of fractality of absorbing material. In the experimental part of the study, 99Tc, 36Cl, 14C, 210Pb and 147Pm radioisotopes have been used as beta sources. In the framework of fractional calculus approach, the experimental and calculated half-value thicknesses of all samples have been obtained in agreement with each other

  1. Measuring dose profiles and surface dose rates of sealed pure-beta sources to determine radioactivity

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Seongmoon; Choi, Chang Heon; Ye, Sung-Joon [Seoul National University, Seoul (Korea, Republic of)

    2015-05-15

    A beta-emitter of radioisotope has been used for therapeutics and diagnostics in medicine. This radionuclide has been also used as fertilizer tracking, thickness gauges and nuclear battery in industrial application . In other words, the demand for associated radioisotope industry has been rising. One of the most important specifications of radioisotope is a radioactivity. Therefore, determining the methodology of radioactivity assay is also becoming an important procedure. The advancement of the sciences associated with radiation detection has contributed to the development of more sensitive, reliable and user friendly calibration systems. The gas-flow proportional counters, liquid scintillation counters, HP-Ge detectors and ionization chambers have been considered to be necessary for the primary calibration systems of radioactivity. The proportional counter is a type of gas-filled detector and designed to measure a detector output that is proportional to the incident radiation energy. The method developed in this study was applied to determine a radioactivity of Sr/Y-90 test source. The radioactivity determined by this method was about 39% lower than one reported by the manufacturer. This difference might result from the lack of accuracy in determining the radioactivity of the original source liquid and the amount of liquid dropped on the absorbent disk. Furthermore, accuracy in the calculated conversion factor mainly relies on how closely to simulate a sealed source and a detector in MCNP.

  2. Measuring dose profiles and surface dose rates of sealed pure-beta sources to determine radioactivity

    International Nuclear Information System (INIS)

    A beta-emitter of radioisotope has been used for therapeutics and diagnostics in medicine. This radionuclide has been also used as fertilizer tracking, thickness gauges and nuclear battery in industrial application . In other words, the demand for associated radioisotope industry has been rising. One of the most important specifications of radioisotope is a radioactivity. Therefore, determining the methodology of radioactivity assay is also becoming an important procedure. The advancement of the sciences associated with radiation detection has contributed to the development of more sensitive, reliable and user friendly calibration systems. The gas-flow proportional counters, liquid scintillation counters, HP-Ge detectors and ionization chambers have been considered to be necessary for the primary calibration systems of radioactivity. The proportional counter is a type of gas-filled detector and designed to measure a detector output that is proportional to the incident radiation energy. The method developed in this study was applied to determine a radioactivity of Sr/Y-90 test source. The radioactivity determined by this method was about 39% lower than one reported by the manufacturer. This difference might result from the lack of accuracy in determining the radioactivity of the original source liquid and the amount of liquid dropped on the absorbent disk. Furthermore, accuracy in the calculated conversion factor mainly relies on how closely to simulate a sealed source and a detector in MCNP

  3. Laser-Induced In-Source Decay Applied to the Determination of Amyloid-Beta in Alzheimer's Brains.

    Science.gov (United States)

    Kelley, Andrea R; Perry, George; Castellani, Rudolph J; Bach, Stephan B H

    2016-03-16

    A method for the analysis of amyloid-beta peptides in isolated plaques and intact tissue sections affected by Alzheimer's disease (AD) is presented. This method employs matrix-assisted laser desorption/ionization (MALDI) time-of-flight mass spectrometry and the inherent laser-induced in-source decay (ISD) that occurs coupled with imaging mass spectrometry (IMS) to investigate the composition of these samples eliminating the need for other confirmational MS/MS techniques. These results demonstrate this technique's usefulness for the identification of amyloid-beta peptides in tissue and isolated senile plaques from AD patients using the reproducible fragmentation pattern demonstrated via the laser-induced ISD of synthetic amyloid-beta peptide clips (1-40, 1-42). Clear differences between the hippocampal AD tissue and the control hippocampal tissue regarding the presence of amyloid-beta have been identified. These are based on laser-induced ISD of standard amyloid-beta clips as controls as well as the analysis of isolated senile plaques as a confirmation before tissue analysis. Using the resulting observed peptide clip masses from the control data, we present mass spectrometry based identification of the amyloid-beta peptides in both isolated plaques and hippocampal regions of those patients diagnosed with AD. PMID:26720297

  4. Peculiarities of the clinical course of radiation sickness and organizational decisions for radiation accidents with beta-gamma sources

    International Nuclear Information System (INIS)

    The analysis of a number of recent large scale accidents involving beta-gamma sources in the last 40 years, such as those of the Marshall Islands (1954); Windscale, UK (1957); Chernobyl, USSR (1986) and Goiania, Brazil (1987) demonstrates the predominance and importance of health and social impacts. (author)

  5. A new method for characterizing beta-ray ophthalmic applicator sources

    International Nuclear Information System (INIS)

    A technique is described which enables one to obtain detailed dose characteristics of 90Sr beta-ray ophthalmic applicators. A radiochromic radiation detector which is a solid-state solution of hexahydroxyethyl pararosaniline cyanide in a nylon polymer (i.e., thin foil), has been used to determine the surface dose rate and dose distribution of these sources. The detectors are rugged, easily handled, have an equivalent response (optical density per unit absorbed dose) to photons and electrons, and produce high-resolution images. They have been found useful for this application due to the high surface dose rates [0.10-1.0 Gy (H2O)/s] and their low sensitivity (approximately 10(4) Gy for an optical density of 1.0). The foils have been evaluated on a He-Ne scanning laser densitometer with a resolution of 0.3 mum. Comparison with NIST (formerly NBS) extrapolation ionization chamber measurements indicates surface dose-rate agreement within 6%. Spectral dosimetric characteristics are presented and discussed

  6. A novel method for large-area sources preparation for the calibration of beta- and alpha-contamination monitors.

    Science.gov (United States)

    Tsoupko-Sitniko, V; Picolo, J L; Carrier, M; Peulon, S; Moutard, G

    2002-01-01

    A method is proposed for the preparation of large-area reference sources for the calibration of beta- and alpha-contamination monitors. It is based on the incorporation, by the ion-exchange mechanism, of the radionuclide in a thin film of a conducting polymer ion-exchanger preliminarily grown on a metal support. Conducting pyrrole-based polymer functionalized by carboxylic cation-exchange groups is used to prepare 60Co and 90Sr-90Y beta-particle sources. Electrochemical polymerization of the corresponding monomer on different conducting supports is studied and a special electrochemical equipment developed permitting the preparation of large-area polymer films of controlled and reproducible thickness. The ion-exchanger obtained is characterized in terms of chemical affinity for cations Co2+ and Sr2+. Incorporation of the radionuclides in the large-area ion-exchanger films thus obtained is studied and optimized with respect to the uniform distribution of the radionuclide. The performance of the procedure is demonstrated using the example of circular sources 44 mm in diameter prepared on stainless steel supports. The sources obtained are characterized in terms of activity, beta-particle flux, uniformity and source efficiency. PMID:11839017

  7. Microglia and macrophages are major sources of locally produced transforming growth factor-beta1 after transient middle cerebral artery occlusion in rats

    DEFF Research Database (Denmark)

    Lehrmann, E; Kiefer, R; Christensen, Thomas;

    1998-01-01

    The potentially neurotrophic cytokine transforming growth factor-beta1 (TGF-beta1) is locally expressed following human stroke and experimental ischemic lesions, but the cellular source(s) and profile of induction have so far not been established in experimental focal cerebral ischemia. This study...... middle cerebral artery. Six hours after ischemia, an early and transient neuronal and microglial expression of TGF-beta1 mRNA was observed in the extraischemic cingulate and frontal cortices. Both early and protracted expression of TGF-beta1 mRNA in the caudate-putamen and neocortical infarcts and in the...

  8. EUV sources for EUV lithography in alpha-, beta-, and high volume chip manufacturing: an update on GDPP and LPP technology

    Science.gov (United States)

    Stamm, U.; Kleinschmidt, J.; Gabel, K.; Hergenhan, G.; Ziener, C.; Schriever, G.; Ahmad, I.; Bolshukhin, D.; Brudermann, J.; de Bruijn, R.; Chin, T. D.; Geier, A.; Gotze, S.; Keller, A.; Korobotchko, V.; Mader, B.; Ringling, J.; Brauner, T.

    2005-05-01

    In the paper we report about the progress made at XTREME technologies in the development of EUV sources based on gas discharge produced plasma (GDPP) technologies and laser produced plasma (LPP) technologies. First prototype xenon GDPP sources of the type XTS 13-35 based on the Z-pinch principle with 35 W power in 2π sr have been integrated into micro-exposure tools from Exitech, UK. Specifications of the EUV sources and experience of integration as well as data about component and optics lifetime are presented. In the source development program for Beta exposure tools and high volume manufacturing exposure tools both tin and xenon have been investigated as fuel for the EUV sources. Development progress in porous metal cooling technology as well as pulsed power circuit design has led to GDPP sources with xenon fuel continuous operating with an output power of 200 W in 2π sr at 4500 Hz repetition rate. With tin fuel an output power of 400 W in 2π sr was obtained leaving all other conditions unaltered with respect to the xenon based source. The performance of the xenon fueled sources is sufficiently good to fulfill all requirements up to the beta tool level. For both the xenon and the tin GDPP sources detailed data about source performance are reported, including component lifetime and optics lifetime. The status of the integration of the sources with grazing incidence collector optics is discussed. Theoretical estimations of collection efficiencies are compared with experimental data to determine the loss mechanisms in the beam path. Specifically contamination issues related to tin as target material as well as debris mitigation in tin sources is addressed. As driver lasers for the LPP source research diode-pumped Nd:YAG lasers have been used to generate EUV emitting plasma. As target material xenon has been employed. Conversion efficiencies have been measured and currently the maximum conversion efficiency amounts to 1 %. The laser driver power of 1.2 kW is

  9. Determination of half-value thickness of aluminum foils for different beta sources by using fractional calculus

    Energy Technology Data Exchange (ETDEWEB)

    Şen, Mürsel, E-mail: senmursel@hotmail.com [Department of Physics, Institute of Science and Technology, Dumlupınar University, Kütahya 43100 (Turkey); Çalık, Abdullah Engin, E-mail: aengin.calik@dpu.edu.tr [Department of Physics, Arts and Sciences Faculty, Dumlupınar University, Kütahya 43100 (Turkey); Ertik, Hüseyin, E-mail: huseyinertik@akdeniz.edu.tr [Department of Mathematics Education, Alanya Faculty of Education, Akdeniz University, Alanya, Antalya 07425 (Turkey)

    2014-09-15

    Reduction of beta-ray intensity with respect to thickness of absorber material exhibits a non-exponential behavior due to the different types of the energy loss processes and many different fractal-like paths followed by beta particles in material. According to Caputo formalism of fractional calculus, the reduction process of beta-ray intensity is governed by using a simple fractional differential equation of order α ≈ 0.31. The solution is obtained in terms of Mittag–Leffler function which depends on a mass attenuation coefficient μ{sub m} and a fractional order α that can be considered as a measure of fractality of absorbing material. In the experimental part of the study, {sup 99}Tc, {sup 36}Cl, {sup 14}C, {sup 210}Pb and {sup 147}Pm radioisotopes have been used as beta sources. In the framework of fractional calculus approach, the experimental and calculated half-value thicknesses of all samples have been obtained in agreement with each other.

  10. Determination of the K shell oscillator strengths and the imaginary form factors of atoms using a weak beta source

    Energy Technology Data Exchange (ETDEWEB)

    Hosur, Savita B; Badiger, N M; Naik, L R [Department of Physics, Karnatak University, Dharwad-580 003 (India)], E-mail: nagappa123@yahoo.co.in

    2008-05-14

    The K shell oscillator strengths and the imaginary form factors of Gd, Hf and Ta atoms have been determined using a novel method. In this method, bremsstrahlung photons produced by beta particles from a weak beta source of {sup 90}Sr-{sup 90}Y in a nickel foil are incident on an elemental target and the transmitted spectrum of photons emerging from the target is measured using an ORTEC make HPGe detector coupled to 8 K multichannel analyser. The recorded spectrum shows a sudden drop at the K shell binding energy of the target atom and an exponential decrease in the intensity above the K shell binding energy. These portions have been used to determine the K shell binding energy, photoelectric cross-section at the K edge, the K shell oscillator strength and the imaginary form factor of the elements Gd, Hf and Ta. Good agreement between the experimental and the theoretical values is observed.

  11. Determination of the K shell oscillator strengths and the imaginary form factors of atoms using a weak beta source

    International Nuclear Information System (INIS)

    The K shell oscillator strengths and the imaginary form factors of Gd, Hf and Ta atoms have been determined using a novel method. In this method, bremsstrahlung photons produced by beta particles from a weak beta source of 90Sr-90Y in a nickel foil are incident on an elemental target and the transmitted spectrum of photons emerging from the target is measured using an ORTEC make HPGe detector coupled to 8 K multichannel analyser. The recorded spectrum shows a sudden drop at the K shell binding energy of the target atom and an exponential decrease in the intensity above the K shell binding energy. These portions have been used to determine the K shell binding energy, photoelectric cross-section at the K edge, the K shell oscillator strength and the imaginary form factor of the elements Gd, Hf and Ta. Good agreement between the experimental and the theoretical values is observed

  12. Characterization of the Theta to Beta Ratio in ADHD: Identifying Potential Sources of Heterogeneity

    Science.gov (United States)

    Loo, Sandra K.; Cho, Alexander; Hale, T. Sigi; McGough, James; McCracken, James; Smalley, Susan L.

    2013-01-01

    Objective: The goal of this study is to characterize the theta to beta ratio (THBR) obtained from electroencephalogram (EEG) measures, in a large sample of community and clinical participants with regard to (a) ADHD diagnosis and subtypes, (b) common psychiatric comorbidities, and (c) cognitive correlates. Method: The sample includes 871…

  13. Energy response of an imaging plate exposed to standard beta sources

    International Nuclear Information System (INIS)

    Imaging plates (IPs) are a reusable media, which when exposed to ionizing radiation, store a latent image that can be read out with a red laser as photostimulated luminescence (PSL). They are widely used as a substitute for X-ray films for diagnostic studies. In diagnostic radiology this technology is known as computed radiography. In this work, the energy response of a commercial IP to beta-particle reference radiation fields used for calibrations at the National Institute of Standards and Technology was investigated. The absorbed dose in the active storage phosphor layer was calculated following the scaling procedure for depth dose for high Z materials with reference to water. It was found that the beta particles from Pm-147 and Kr-85 gave 68% and 24% higher PSL responses than that induced by Sr-90, respectively, which was caused by the different PSL detection efficiencies. In addition, normalized response curves of the IPs as a function of depth in polystyrene were measured and compared with the data measured using extrapolation chamber techniques. The difference between both sets of data resulted from the continuous energy change as the beta particle travels across the material, which leads to a different PSL response

  14. Source analysis of beta-synchronisation and cortico-muscular coherence after movement termination based on high resolution electroencephalography.

    Directory of Open Access Journals (Sweden)

    Muthuraman Muthuraman

    Full Text Available We hypothesized that post-movement beta synchronization (PMBS and cortico-muscular coherence (CMC during movement termination relate to each other and have similar role in sensorimotor integration. We calculated the parameters and estimated the sources of these phenomena.We measured 64-channel EEG simultaneously with surface EMG of the right first dorsal interosseus muscle in 11 healthy volunteers. In Task1, subjects kept a medium-strength contraction continuously; in Task2, superimposed on this movement, they performed repetitive self-paced short contractions. In Task3 short contractions were executed alone. Time-frequency analysis of the EEG and CMC was performed with respect to the offset of brisk movements and averaged in each subject. Sources of PMBS and CMC were also calculated.High beta power in Task1, PMBS in Task2-3, and CMC in Task1-2 could be observed in the same individual frequency bands. While beta synchronization in Task1 and PMBS in Task2-3 appeared bilateral with contralateral predominance, CMC in Task1-2 was strictly a unilateral phenomenon; their main sources did not differ contralateral to the movement in the primary sensorimotor cortex in 7 of 11 subjects in Task1, and in 6 of 9 subjects in Task2. In Task2, CMC and PMBS had the same latency but their amplitudes did not correlate with each other. In Task2, weaker PMBS source was found bilaterally within the secondary sensory cortex, while the second source of CMC was detected in the premotor cortex, contralateral to the movement. In Task3, weaker sources of PMBS could be estimated in bilateral supplementary motor cortex and in the thalamus. PMBS and CMC appear simultaneously at the end of a phasic movement possibly suggesting similar antikinetic effects, but they may be separate processes with different active functions. Whereas PMBS seems to reset the supraspinal sensorimotor network, cortico-muscular coherence may represent the recalibration of cortico-motoneuronal and

  15. Elaboration of Co-60 sources on gilding vyns, with beta efficiencies 80 % or better and its activity measure by the coincidences method

    International Nuclear Information System (INIS)

    The measuring technique of radioactive activity by the coincidences method 4 π β- γ it requires of the elaboration of radioactive sources on thin supports in order to flows the biggest percentage of beta particles, those of the order of the 80 % or but. In this work a procedure for the elaboration of this type of sources, with gilding Vyns is reported. (Author)

  16. Radioluminescence (RL) probe dosimetry using Al2O3:C for precise calibration of beta sources applied in luminescence dating

    International Nuclear Information System (INIS)

    The radioluminescence (RL) phenomenon is widely known as prompt luminescence or fluorescence of synthetic materials, like Al2O3 and LiF as well as of natural dosimeter materials, like feldspar and quartz, during interaction with ionising radiation, especially electron rays. Almost all of these materials show increasing RL flux with increasing absorbed beta dose. Only potassium rich feldspars (microcline and orthoclase) show a RL emission at 1.45 eV of decreasing intensity with rising delivered dose. For a number of reasons, this RL emission is suitable for dating purposes. Accuracy and reproducibility of the RL dating method are much more advantageous compared to TL and OSL methods. Carbon doped Al2O3 (TLD 500) shows a much more higher RL intensity than, e.g., feldspar and the stability of the stored electrons as well as the linearity of RL yield versus primary electron energy, qualifies this dosimeter material to be a useful tool in source calibration, using radioluminescence. However, the accuracy of a luminescence dating method depends largely on the calibration of the used irradiation sources. To prevent calibration uncertainties due to the use of natural dosimeters with a high scattering of luminescence yield, a new method is suggested. This method bases on probe dosimetry using a very small amount of Al2O3:C as probe and, consequently, the material that should be calibrated (e.g. feldspar). The amount of Al2O3:C may disturb the electron fluence within the material to be calibrated only insignificantly. The sample mix is irradiated by an exactly known Gamma or Beta radiation source and the absorbed dose is treated as absorbed dose in the appropriated material. In contrast to conventional calibration methods, the suggested performance uses the dose dependent RL signal of Al2O3:C at 3.00 eV. This shows a good reproducibility, even with a tiny amount of the applied synthetic probe material. (author)

  17. A primary standard for the measurement of alpha and beta particle surface emission rate from large area reference sources.

    Science.gov (United States)

    Ravindra, Anuradha; Kulkarni, D B; Joseph, Leena; Kulkarni, M S; Babu, D A R

    2016-01-01

    A large area windowless gas flow multi wire proportional counting system for the calibration of large area reference sources has been developed as a primary standard at Bhabha Atomic Research Centre (BARC). The counting system consists of a multi wire proportional counter (MWPC), vacuum system, gas flow system and pulse processing units. The MWPC detector assembly consists of a vacuum tight aluminum enclosure, multi wire grid and sliding source tray. Various detector characteristics like operating characteristics curve, Fe-55 spectrum for beta discriminator threshold setting and dead time of the measurement system were studied and determined in order to achieve an optimized detection capability. The surface emission rates of different source strengths were measured and their relative combined standard uncertainties were determined. Large Area Sources Comparison Exercise (LASCE) was organized by International Committee on Radionuclide Metrology (ICRM) working group and coordinated by National Institute for Ionising Radiation Metrology (ENEA), Italy, to demonstrate equivalence of surface emission rate measurements at the international platform. BARC participated in the programme and the results of LASCE are also discussed in this paper. PMID:26457924

  18. Calibration of photon and beta ray sources used in brachytherapy. Guidelines on standardized procedures at Secondary Standards Dosimetry Laboratories

    International Nuclear Information System (INIS)

    It has generally been recognized that international harmonization in radiotherapy dosimetry is essential. Consequently, the IAEA has given much effort to this, for example by publishing a number of reports in the Technical Reports Series (TRS) for external beam dosimetry, most notably TRS-277 and more recently TRS-398. Both of these reports describe in detail the steps to be taken for absorbed dose determination in water and they are often referred to as 'dosimetry protocols'. Similar to TRS-277, it is expected that TRS-398 will be adopted or used as a model by a large number of countries as their national protocol. In 1996, the IAEA established a calibration service for low dose rate (LDR) 137 Cs brachytherapy sources, which is the most widely used source for treatment of gynecological cancer. To further enhance harmonization in brachytherapy dosimetry, the IAEA published in 1999 IAEA-TECDOC-1079 entitled 'Calibration of Brachytherapy Sources. Guidelines on Standardized Procedures for the Calibration of Brachytherapy Sources at Secondary Standard Dosimetry Laboratories (SSDLs) and Hospitals'. The report was well received and was distributed in a large number of copies to the members of the IAEA/WHO network of SSDLs and to medical physicists working with brachytherapy. The present report is an update of the aforementioned TECDOC. Whereas TECDOC-1079 described methods for calibrating brachytherapy sources with photon energies at or above those of 192Ir, the current report has a wider scope in that it deals with standardization of calibration of all the most commonly used brachytherapy sources, including both photon and beta emitting sources. The latter sources have been in use for a few decades already, but their calibration methods have been unclear. Methods are also described for calibrating sources used in the rapidly growing field of cardiovascular angioplasty. In this application, irradiation of the vessel wall is done in an attempt to prevent restenosis after

  19. Interlaboratory beta source calibration using TL and OSL on natural quartz

    DEFF Research Database (Denmark)

    Goksu. H.Y.; Bailiff, I.K.; Bøtter-Jensen, L.; Brodski, L.; Hutt, G.; Stoneham, D.

    1995-01-01

    Laboratory at GSF using a Go-60 source as well as the in situ measurements with an ionization chamber, calibrated to the primary standards of PTB Braunschweig. Irradiated and unirradiated quartz was distributed to the five laboratories and although different procedures were used for thermoluminescence and...

  20. Elements of a thermic method of preparing beta-sources with fused carriers, including strontium-90

    International Nuclear Information System (INIS)

    Sources of ionizing radiation based on the radioisotope Sr90 are widely used in apparatus and systems of automatic control and regulation of industrial processes. The technology of the preparation of sources is based on dehydration of a mixture of a radioactive solution of strontium nitrate with components such as boric anhydride, silica, and alumina. Thermic treatment of the dehydrated mixture at a high temperature produces a very mobile melt. This cools to a vitreous mass containing the required quantity of the radioisotope Sr90. The paper gives data and discusses the results of dehydration of the system SrO - B2O3 - SiO2 within a temperature range of 100 - 1000oC and justifies the choice of the main parameters of the technological process. It summarizes a method of mounting a vitreous preparation containing the required quantity of the radioisotope Sr90 on bases of various shapes and sizes made of steel, ceramic and other materials. The authors discuss the main parameters, ensuring that various types of sources shall be reliable and safe in operation, and give data of Sr90 sources prepared by the thermic method. (author)

  1. Development of a {sup 147}Pm source for beta-backscatter thickness gauge applications

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Manoj; Udhayakumar, J. [Radiopharmaceuticals Division, Bhabha Atomic Research Center, Radiological Laboratory, Trombay, Mumbai 400 085 (India); Nuwad, J.; Shukla, Rakesh; Pillai, C.G.S. [Chemistry Division, Bhabha Atomic Research Center, Trombay, Mumbai 400 085 (India); Dash, Ashutosh, E-mail: adash@barc.gov.i [Radiopharmaceuticals Division, Bhabha Atomic Research Center, Radiological Laboratory, Trombay, Mumbai 400 085 (India); Venkatesh, Meera [Radiopharmaceuticals Division, Bhabha Atomic Research Center, Radiological Laboratory, Trombay, Mumbai 400 085 (India)

    2011-03-15

    This paper describes a method for the preparation of {sup 147}Pm sources, utilized in the determination of graphite coating thickness on the inner surface of the zircaloy cladding tube of nuclear fuels. {sup 147}Pm was adsorbed on a limited surface area [1.5 mm ({phi})x2 mm (l)] of a cylindrical aluminum rod [1.5 mm ({phi})x10 mm (l)]. In brief, the selected tip area [1.5 mm ({phi})x2 mm (l)] was anodized at a current density of 15 mA/cm{sup 2} at 15 {sup o}C in 3 M.H{sub 2}SO{sub 4} for 2 h followed by immersion of this area in 10 {mu}L of {sup 147}Pm solution containing 37 MBq (1 mCi) of activity at pH 6.0 for 24 h. The radioactive area was subsequently covered with a thin layer of Polymethyl Methacrylate (PMMA) to prevent leaching of {sup 147}Pm from the source. The quantity of incorporated {sup 147}Pm activity was assayed in a calibrated ion chamber. Quality control tests were carried out to ensure nonleachability, uniform distribution of activity and stability of the sources.

  2. Determination of the dose rapidity of a {sup 90} Sr beta radiation source using thermoluminescent dosemeters; Determinacion de la rapidez de dosis de una fuente de radiacion beta de {sup 90}Sr usando dosimetros termoluminiscentes

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez M, P.R.; Azorin N, J.; Rivera M, T. [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    2000-07-01

    The thermoluminescent dosemeters developed in Mexico, have been used efficiently in environmental and personal dosimetry. When the dose rate of some source is not known can be estimated with the use of thermoluminescent dosemeters taking in account the geometrical array used in the irradiations for reproducibility of the results in posterior irradiations. In this work it was estimated the dose rate of a {sup 90} Sr-{sup 90} Y beta radiation source which is property of the Nuclear Sciences Institute, UNAM, therefore it was l ended to the Metropolitan Autonomous University- Iztapalapa Unit for the characterization of new Tl materials, taking account of the institutional collaboration agreements. (Author)

  3. Monte Carlo-based Bragg-Gray tissue-to-air mass-collision-stopping power ratios for ISO beta sources

    International Nuclear Information System (INIS)

    Quantity of interest in external beta radiation protection is the absorbed dose rate to tissue at a depth of 7 mg/cm2 Dt (7 mg/cm2) in a 4-element ICRU (International Commission for Radiation Units and Measurements) unit density tissue phantom. ISO (International Organization for Standardization) 6980-2 provides guidelines to establish this quantity for beta emitters using an extrapolation chamber as a primary standard. ISO 6980-1 proposes two series of beta reference radiation fields, namely, series 1 and series 2. Series 1 covers 90Sr/90Y, 85Kr, 204Tl and 147Pm sources used with beam flattening filter and Series 2 covers 14C and 106Ru/106Rh sources used with beam flattening filter. Dt (7 mg/cm2) is realized based on measured current and set of corrections including Bragg-Gray tissue-to-air mass-stopping power ratio, (S/ρ)t,a. ISO provides (S/ρ)t,a values which are based on approximate methods. The present study is aimed at calculating (S/ρ)t,a for 90Sr/90Y, 85Kr, 106Ru/106Rh and 147Pm sources using the Monte Carlo (MC) methods and compare the same against the ISO values. By definition, (S/ρ)t,a should be independent of cavity length of the chamber which was verified in the work

  4. BETA-S, Multi-Group Beta-Ray Spectra

    International Nuclear Information System (INIS)

    1 - Description of program or function: BETA-S calculates beta-decay source terms and energy spectra in multigroup format for time-dependent radionuclide inventories of actinides, fission products, and activation products. Multigroup spectra may be calculated in any arbitrary energy-group structure. The code also calculates the total beta energy release rate from the sum of the average beta-ray energies as determined from the spectral distributions. BETA-S also provides users with an option to determine principal beta-decaying radionuclides contributing to each energy group. The CCC-545/SCALE 4.3 (or SCALE4.2) code system must be installed on the computer before installing BETA-S, which requires the SCALE subroutine library and nuclide-inventory generation from the ORIGEN-S code. 2 - Methods:Well-established models for beta-energy distributions are used to explicitly represent allowed, and 1., 2. - and 3. -forbidden transition types. Forbidden non-unique transitions are assumed to have a spectral shape of allowed transitions. The multigroup energy spectra are calculated by numerically integrating the energy distribution functions using an adaptive Simpson's Rule algorithm. Nuclide inventories are obtained from a binary interface produced by the ORIGEN-S code. BETA-S calculates the spectra for all isotopes on the binary interface that have associated beta-decay transition data in the ENSDF-95 library, developed for the BETA-S code. This library was generated from ENSDF data and contains 715 materials, representing approximately 8500 individual beta transition branches. 3 - Restrictions on the complexity of the problem: The algorithms do not treat positron decay transitions or internal conversion electrons. The neglect of positron transitions in inconsequential for most applications involving aggregate fission products, since most of the decay modes are via electrons. The neglect of internal conversion electrons may impact on the accuracy of the spectrum in the low

  5. Monte Carlo-based Spencer-Attix and Bragg-Gray tissue-to-air stopping power ratios for ISO beta sources

    International Nuclear Information System (INIS)

    Spencer-Attix (SA) and Bragg-Gray (BG) mass-collision-stopping-power ratios of tissue-to-air are calculated using a modified version of EGSnrc-based SPRRZnrc user-code for the International Organization for Standardization (ISO) beta sources such as 147Pm, 85Kr, 90Sr/90Y and 106Ru/106Rh. The ratios are calculated at 5 and 70 μm depths along the central axis of the unit density ICRU-4-element tissue phantom as a function of air-cavity lengths of the extrapolation chamber l = 0.025-0.25 cm. The study shows that the BG values are independent of l and agree well with the ISO-reported values for the above sources. The overall variation in the SA values is ∼0.3 % for all the investigated sources, when l is varied from 0.025 to 0.25 cm. As energy of the beta increases the SA stopping-power ratio for a given cavity length decreases. For example, SA values of 147Pm are higher by ∼2 % when compared with the corresponding values of 106Ru/106Rh source. SA stopping-power ratios are higher than the BG stopping-power ratios and the degree of variation depends on type of source and the value of l. For example, the difference is up to 0.7 % at l = 0.025 cm for the 90Sr/90Y source. (authors)

  6. Characteristics of a 85Kr beta-particle source applied in Series 1 reference irradiations of TMDIS-1 direct ion storage dosemeters

    International Nuclear Information System (INIS)

    Characteristics necessary to specify an ISO 6980 Series 1 reference radiation field were determined for a commercially available 85Kr beta-particle source, using a BEAM EGS4 Monte Carlo code. The characteristics include residual maximum beta energy, Eres, and the uniformity of the dose rate over the calibration area. The Eres and the uniformity were also determined experimentally, using an extrapolation ionization chamber (EC) and a 0.2 cm3 parallel plate ionization chamber, respectively. The depth-dose curve measured with the EC gave a value 0.62 MeV for the Eres. Series 2 90Sr + 90Y and Series 1 85Kr beta-particle sources calibrated for Hp(0.07) at the secondary standard dosimetry laboratory (SSDL) of STUK were used to determine the energy and angular responses of TMDIS-1 direct ion storage dosemeters. The averaged zero angle Hp(0.07) responses to the 90Sr + 90Y and 85Kr reference radiations were 135 and 80%, respectively. The responses were normalized to 100%, Hp (0.07) response to 137Cs photon radiation. (authors)

  7. Nucleotide excision repair DNA synthesis by excess DNA polymerase beta: a potential source of genetic instability in cancer cells.

    Science.gov (United States)

    Canitrot, Y; Hoffmann, J S; Calsou, P; Hayakawa, H; Salles, B; Cazaux, C

    2000-09-01

    The nucleotide excision repair pathway contributes to genetic stability by removing a wide range of DNA damage through an error-free reaction. When the lesion is located, the altered strand is incised on both sides of the lesion and a damaged oligonucleotide excised. A repair patch is then synthesized and the repaired strand is ligated. It is assumed that only DNA polymerases delta and/or epsilon participate to the repair DNA synthesis step. Using UV and cisplatin-modified DNA templates, we measured in vitro that extracts from cells overexpressing the error-prone DNA polymerase beta exhibited a five- to sixfold increase of the ultimate DNA synthesis activity compared with control extracts and demonstrated the specific involvement of Pol beta in this step. By using a 28 nt gapped, double-stranded DNA substrate mimicking the product of the incision step, we showed that Pol beta is able to catalyze strand displacement downstream of the gap. We discuss these data within the scope of a hypothesis previously presented proposing that excess error-prone Pol beta in cancer cells could perturb the well-defined specific functions of DNA polymerases during error-free DNA transactions. PMID:10973926

  8. Beta Thalassemia

    Science.gov (United States)

    ... South Asian (Indian, Pakistani, etc.), Southeast Asian and Chinese descent. 1 Beta Thalassemia ßß Normal beta globin ... then there is a 25% chance with each pregnancy that their child will inherit two abnormal beta ...

  9. Procedure to carry out leakage test in beta radiation sealed sources emitters of {sup 90}Sr/{sup 90}Y; Procedimiento para realizar prueba de fuga en fuentes selladas de radiacion beta emisoras de {sup 90}Sr/{sup 90}Y

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez R, J. T., E-mail: trinidad.alvarez@inin.gob.m [ININ, Departamento de Metrologia de Radiaciones Ionizantes, Laboratorio Secundario de Calibracion Dosimetrica, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2010-09-15

    In the alpha-beta room of the Secondary Laboratory of Dosimetric Calibration of the Metrology Department of Ionizing Radiations ophthalmic applicators are calibrated in absorbed dose terms in water D{sub w}; these applicators, basically are emitter sealed sources of pure beta radiation of {sup 90}Sr / {sup 90}Y. Concretely, the laboratory quality system indicates to use the established procedure for the calibration of these sources, which establishes the requirement of to carry out a leakage test, before to calibrate the source. However, in the Laboratory leakage test certificates sent by specialized companies in radiological protection services have been received, in which are used gamma spectrometry equipment s for beta radiation leakage tests, since it is not reliable to detect pure beta radiation with a scintillating detector with NaI crystal, (because it could detect the braking radiation produced in the detector). Therefore the Laboratory has had to verify the results of the tests with a correct technique, with the purpose of determining the presence of sources with their altered integrity and radioactive material leakage. The objective of this work is to describe a technique for beta activity measurement - of the standard ISO 7503, part 1 (1988) - and its application with a detector Gm plane (type pankage) in the realization of leakage tests in emitter sources of pure beta radiation, inside the mark of quality assurance indicated by the report ICRU 76. (Author)

  10. Application of gel dosimetry - A preliminary study on verification of uniformity of activity and length of source used in Beta-Cath system

    International Nuclear Information System (INIS)

    Recently the intraluminal irradiation of coronary arteries following balloon angioplasty is found to reduce proliferation of smooth muscle cells and restenosis. Among the isotopes used for the intracoronary irradiation, 90Sr/Y appears to be ideal (H I Almos et al, 1996). In 1984 Gore et al proposed that radiation induced changes in the well-established Fricke solution could be probed with Nuclear Magnetic Resonance (NMR) relaxation measurements rather than using conventional spectrophotometry measurements. This was a major step in the development of gel dosimetry and since then gel dosimetry has been one of the major advances in the dosimetry of complex radiation fields has been in the area of gel dosimetry. In this preliminary work on gel dosimetry we present the verification of uniformity of activity along the length of the source train and verification of the length of the source used in the Beta-Cath system used for intracoronary brachytherapy with ferrous gel dosimeter. The Beta-Cath system obtained from Novoste, Norcross, GA was used in this study. It consists of a source train of 16 90Sr/Y sources each of length 2.5mm. The total length of the source train is 40mm. For preparation of the Ferrous-Gelatin Gel, the recipe provided by the London Regional Cancer Center, London Ontario, Canada was used. Stock solutions of 50mM H2SO4, 0.3 mM ferrous ammonium sulphate, 0.05mM Xylenol orange was first prepared. The gel was prepared by mixing 4% gelatin with distilled water while stirring in a water bath at 40-42 deg. C. Acid solution, Ferrous ammonium sulphate solution and Xylenol orange were added and stirred in the water bath for about an hour to allow aeration. The mixture was poured in to three 20ml syringes to form the gel and stored in the refrigerator at 5 deg. C. For irradiation with Beta-Cath, the gel was prepared in three cylindrical 20ml syringes. A nylon tube having the same dimension as that of the delivery catheter used in intra-coronary was placed at

  11. Effects of anisotropic fluences and angular depended spectra of beta-particles in the use of large area reference sources

    International Nuclear Information System (INIS)

    Calibrations of instrument efficiency of surface contamination meters are usually made with extended reference sources which are standardized in terms of 2π surface β-particle emission rates from the source surface including backscattered particles. Extended sources supplied from various metrology institutes or calibration laboratories, but the source-types such as structure, preparation method, backing and covering materials vary between manufacturers. In this work first we show how the calibration results are dependent on the source type. Second, in order to clarify the possible reason of such discrepancy, we examined the isotropy of β-particle fluences by the use of a proportional counter and also observed the angular dependence of β-particle spectra by the use of small plastic scintillation spectrometer, where the source mount can rotate relative to the detector window at various obliquities. The discrepancy in the instrument-calibration of surface contamination meters, which are mainly used under the conditions of large source-to-detector geometry, can be explained. - Highlights: ► We show how the calibration results are dependent on the source type. ► We examined the isotropy of β-particle fluences and observed the angular dependence. ► Discrepancy of instrument efficiencies using different type of sources is explained.

  12. Radon Progenies as a Source of Gross Alpha-beta Activities in Drinking Water in Vinaninkarena, Antsirabe-Madagascar

    International Nuclear Information System (INIS)

    The village of Vinaninkarena, Antsirabe, Madagascar is located in a high radioactivity area. With the aim of assessing the health impact of radioactivity pollution, a survey was conducted around an abandoned radium mining. Waters from 24 sampling points, including 5 wells and 13 springs were sampled. The water radioactivity was measured using a portable Triathler LSC, model 425-034 from Hidex Turku. Each sample is counted more than 3 times: less than 2h after sampling, 4h to few days and more than 3 weeks after when 226Ra attains equilibrium with 222Rn and its short-lived daughters. Combination of water non miscible, radon extractive LS cocktail and water miscible one is used to reveal contribution of radium, radon and its short lived progenies to the gross alpha-beta activities. Maximum activity values found are : 3.6±0.3 Bq.L-1 for 226Ra, 554±9 Bq.L-1 for the excess of radon, and 408±8 Bq.L-1 for the excess of radon progenies. Based on these data, a daily consumption of 2 L of these waters by a standard person would produce an annual 226Ra ingestion well above the annual intake limit for 226Ra. Moreover, the increasing gross alpha-beta activity resulting from radon progenies raises the issue of health effects. The potential for rapid spring-to-mouth delivery, which is frequent in rural area, may expose the water consumer to the short-lived alpha particle emitters.

  13. Effects of anisotropic fluences and angular depended spectra of beta-particles in the use of large area reference sources.

    Science.gov (United States)

    Yamada, Takahiro; Kawada, Yasushi; Ishizu, Hidetake; Yamamoto, Shinich; Yunoki, Akira; Sato, Yasushi; Unno, Yasuhiro; Hino, Yoshio

    2012-09-01

    Calibrations of instrument efficiency of surface contamination meters are usually made with extended reference sources which are standardized in terms of 2π surface β-particle emission rates from the source surface including backscattered particles. Extended sources supplied from various metrology institutes or calibration laboratories, but the source-types such as structure, preparation method, backing and covering materials vary between manufacturers. In this work first we show how the calibration results are dependent on the source type. Second, in order to clarify the possible reason of such discrepancy, we examined the isotropy of β-particle fluences by the use of a proportional counter and also observed the angular dependence of β-particle spectra by the use of small plastic scintillation spectrometer, where the source mount can rotate relative to the detector window at various obliquities. The discrepancy in the instrument-calibration of surface contamination meters, which are mainly used under the conditions of large source-to-detector geometry, can be explained. PMID:22424745

  14. Results of the BiPo-1 prototype for radiopurity measurements for the SuperNEMO double beta decay source foils

    CERN Document Server

    Argyriades, J; Augier, C; Baker, J; Barabash, A S; Basharina-Freshville, A; Bongrand, M; Bourgeois, C; Breton, D; Briére, M; Broudin-Bay, G; Brudanin, V B; Caffrey, A J; Cebrián, S; Chapon, A; Chauveau, E; Dafni, Th; Díaz, J; Durand, D; Egorov, V G; Evans, J J; Flack, R; Fushima, K-I; Irastorza, I G; Garrido, X; Gómez, H; Guillon, B; Holin, A; Holy, K; Horkey, J J; Hubert, P; Hugon, C; Iguaz, F J; Ishihara, N; Jackson, C M; Jenzer, S; Jullian, S; Kauer, M; Kochetov, O I; Konovalov, S I; Kovalenko, V; Lamhamdi, T; Lang, K; Lemiére, Y; Lutter, G; Luzón, G; Mamedov, F; Marquet, Ch; Mauger, F; Monrabal, F; Nachab, A; Nemchenok, I B; Nguyen, C H; Nomachi, M; Nova, F; Ohsumi, H; Pahlka, R B; Perrot, F; Piquemal, F; Povinec, P P; Richards, B; Ricol, J S; Riddle, C L; Rodríguez, A; Saakyan, R; Sarazin, X; Sedgbeer, J K; Serra, L; Shitov, Yu A; Simard, L; Šimkovic, F; Söldner-Rembold, S; Štekl, I; Sutton, C S; Tamagawa, Y; Szklarz, G; Thomas, J; Timkin, V; Tretyak, V; Tretyak, Vl I; Umatov, V I; Vála, L; Vanyushin, I A; Vasiliev, R; Vasiliev, V A; Vorobel, V; Waters, D; Yahali, N; Žukauskas, A

    2010-01-01

    The development of BiPo detectors is dedicated to the measurement of extremely high radiopurity in $^{208}$Tl and $^{214}$Bi for the SuperNEMO double beta decay source foils. A modular prototype, called BiPo-1, with 0.8 $m^2$ of sensitive surface area, has been running in the Modane Underground Laboratory since February, 2008. The goal of BiPo-1 is to measure the different components of the background and in particular the surface radiopurity of the plastic scintillators that make up the detector. The first phase of data collection has been dedicated to the measurement of the radiopurity in $^{208}$Tl. After more than one year of background measurement, a surface activity of the scintillators of $\\mathcal{A}$($^{208}$Tl) $=$ 1.5 $\\mu$Bq/m$^2$ is reported here. Given this level of background, a larger BiPo detector having 12 m$^2$ of active surface area, is able to qualify the radiopurity of the SuperNEMO selenium double beta decay foils with the required sensitivity of $\\mathcal{A}$($^{208}$Tl) $<$ 2 $\\mu$...

  15. Results of the BiPo-1 prototype for radiopurity measurements for the SuperNEMO double beta decay source foils

    Energy Technology Data Exchange (ETDEWEB)

    Argyriades, J. [LAL, Universite Paris-Sud, CNRS/IN2P3, F-91405 Orsay (France); Arnold, R. [IPHC, Universite de Strasbourg, CNRS/IN2P3, F-67037 Strasbourg (France); Augier, C. [LAL, Universite Paris-Sud, CNRS/IN2P3, F-91405 Orsay (France); Baker, J. [INL, Idaho Falls, ID 83415 (United States); Barabash, A.S. [Institute of Theoretical and Experimental Physics, 117259 Moscow (Russian Federation); Basharina-Freshville, A. [University College London, WC1E 6BT London (United Kingdom); Bongrand, M.; Bourgeois, C.; Breton, D.; Briere, M.; Broudin-Bay, G. [LAL, Universite Paris-Sud, CNRS/IN2P3, F-91405 Orsay (France); Brudanin, V.B. [Joint Institute for Neear Research, 141980 Dubna (Russian Federation); Caffrey, A.J. [INL, Idaho Falls, ID 83415 (United States); Carcel, S. [Instituto de Fisica Corpuscular, CSIC, Universidad de Valencia, Valencia (Spain); Cebrian, S. [Instituto de Fisica Nuclear y Altas Energias, Universidad de Zaragoza, Zaragoza (Spain); Chapon, A. [LPC Caen, ENSICAEN, Universite de Caen, CNRS/IN2P3, F-14032 Caen (France); Chauveau, E. [CNRS/IN2P3, Centre d' Etudes Nucleaires de Bordeaux Gradignan, UMR 5797, F-33175 Gradignan (France); Universite de Bordeaux, Centre d' Etudes Nucleaires de Bordeaux Gradignan, UMR 5797, F-33175 Gradignan (France); Dafni, Th. [Instituto de Fisica Nuclear y Altas Energias, Universidad de Zaragoza, Zaragoza (Spain); Diaz, J. [Instituto de Fisica Corpuscular, CSIC, Universidad de Valencia, Valencia (Spain); Durand, D. [LPC Caen, ENSICAEN, Universite de Caen, CNRS/IN2P3, F-14032 Caen (France)

    2010-10-01

    The development of BiPo detectors is dedicated to the measurement of extremely high radiopurity in {sup 208}Tl and {sup 214}Bi for the SuperNEMO double beta decay source foils. A modular prototype, called BiPo-1, with 0.8 m{sup 2} of sensitive surface area, has been running in the Modane Underground Laboratory since February, 2008. The goal of BiPo-1 is to measure the different components of the background and in particular the surface radiopurity of the plastic scintillators that make up the detector. The first phase of data collection has been dedicated to the measurement of the radiopurity in {sup 208}Tl. After more than one year of background measurement, a surface activity of the scintillators of A({sup 208}Tl)=1.5{mu}Bq/m{sup 2} is reported here. Given this level of background, a larger BiPo detector having 12 m{sup 2} of active surface area, is able to qualify the radiopurity of the SuperNEMO selenium double beta decay foils with the required sensitivity of A({sup 208}Tl)<2{mu}Bq/kg (90% C.L.) with a six month measurement.

  16. Calibration of photon and beta ray sources used in brachytherapy. Guidelines on standardized procedures at Secondary Standards Dosimetry Laboratories (SSDLs) and hospitals

    International Nuclear Information System (INIS)

    It has generally been recognized that international harmonization in radiotherapy dosimetry is essential. Consequently, the IAEA has given much effort to this, for example by publishing a number of reports in the Technical Reports Series (TRS) for external beam dosimetry, most notably TRS-277 and more recently TRS-398. Both of these reports describe in detail the steps to be taken for absorbed dose determination in water and they are often referred to as 'dosimetry protocols'. Similar to TRS-277, it is expected that TRS-398 will be adopted or used as a model by a large number of countries as their national protocol. In 1996, the IAEA established a calibration service for low dose rate (LDR) 137 Cs brachytherapy sources, which is the most widely used source for treatment of gynecological cancer. To further enhance harmonization in brachytherapy dosimetry, the IAEA published in 1999 IAEA-TECDOC-1079 entitled 'Calibration of Brachytherapy Sources. Guidelines on Standardized Procedures for the Calibration of Brachytherapy Sources at Secondary Standard Dosimetry Laboratories (SSDLs) and Hospitals'. The report was well received and was distributed in a large number of copies to the members of the IAEA/WHO network of SSDLs and to medical physicists working with brachytherapy. The present report is an update of the aforementioned TECDOC. Whereas TECDOC-1079 described methods for calibrating brachytherapy sources with photon energies at or above those of 192Ir, the current report has a wider scope in that it deals with standardization of calibration of all the most commonly used brachytherapy sources, including both photon and beta emitting sources. The latter sources have been in use for a few decades already, but their calibration methods have been unclear. Methods are also described for calibrating sources used in the rapidly growing field of cardiovascular angioplasty. In this application, irradiation of the vessel wall is done in an attempt to prevent restenosis after

  17. Identification of alpha-beta unsaturated aldehydes as sources of toxicity to activated sludge biomass in polyester manufacturing wastewater.

    Science.gov (United States)

    Caffaro-Filho, R A; Wagner, R; Umbuzeiro, G A; Grossman, M J; Durrant, L R

    2010-01-01

    Wastewater generated in industrial production processes are often contaminated by hazardous chemicals. Characterization by means of toxicity-directed analysis is useful for identifying which fractions of a waste stream possess the most toxicity. We applied this approach to evaluate toxic components of a polyester manufacturing wastewater. Using the reduction in oxygen uptake rate of activated sludge as an indicator of toxicity, it was determined that increasing the pH from 3 to 11 followed by air stripping significantly reduced the toxicity of the wastewater. Comparative headspace GC/MS analysis of wastewater at different pHs selected a group of Volatile Organic Compounds (VOCs) associated with the observed effect of air stripping at pH 11. Ten of these compounds were identified as alpha,beta unsaturated aldehydes (acrolein (2-propenal) congeners); these compounds are known to be toxic as well as mutagenic. Confirmation that these compounds were a cause of toxicity was achieved by demonstrating that removal of these compounds by air stripping significantly reduced the wastewater mutagenic potency in a Salmonella mutagenicity assay. Formation of these volatile compounds by base catalyzed aldol condensation at pH 11 may account for the effectiveness of air stripping in reducing toxicity. To date there is no record in the literature about the toxicity and presence of acrolein congeners in polyester manufacturing wastewater. PMID:20418629

  18. Special Analysis for the Disposal of the Lawrence Livermore National Laboratory Low Activity Beta/Gamma Sources Waste Stream at the Area 5 Radioactive Waste Management Site, Nevada National Security Site, Nye County, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    Shott, Gregory J. [National Security Technologies, LLC

    2015-06-01

    This special analysis (SA) evaluates whether the Lawrence Livermore National Laboratory (LLNL) Low Activity Beta/Gamma Sources waste stream (BCLALADOEOSRP, Revision 0) is suitable for disposal by shallow land burial (SLB) at the Area 5 Radioactive Waste Management Site (RWMS) at the Nevada National Security Site (NNSS). The LLNL Low Activity Beta/Gamma Sources waste stream consists of sealed sources that are no longer needed. The LLNL Low Activity Beta/Gamma Sources waste stream required a special analysis because cobalt-60 (60Co), strontium-90 (90Sr), cesium-137 (137Cs), and radium-226 (226Ra) exceeded the NNSS Waste Acceptance Criteria (WAC) Action Levels (U.S. Department of Energy, National Nuclear Security Administration Nevada Field Office [NNSA/NFO] 2015). The results indicate that all performance objectives can be met with disposal of the LLNL Low Activity Beta/Gamma Sources in a SLB trench. The LLNL Low Activity Beta/Gamma Sources waste stream is suitable for disposal by SLB at the Area 5 RWMS. However, the activity concentration of 226Ra listed on the waste profile sheet significantly exceeds the action level. Approval of the waste profile sheet could potentially allow the disposal of high activity 226Ra sources. To ensure that the generator does not include large 226Ra sources in this waste stream without additional evaluation, a control is need on the maximum 226Ra inventory. A limit based on the generator’s estimate of the total 226Ra inventory is recommended. The waste stream is recommended for approval with the control that the total 226Ra inventory disposed shall not exceed 5.5E10 Bq (1.5 Ci).

  19. Detection of beta-class variability in Black Hole source GRS 1915+105 by Astrosat Scanning Sky Monitor

    Science.gov (United States)

    Ramadevi, M. C.; Ravishankar, B. T.; Nandi, Anuj; Girish, V.; Singh, Brajpal; Jain, Anand; Agrawal, Vivek Kumar; Agarwal, Anil; Bhattacharya, Dipankar; Seetha, S.; Sharma, M. Ramakrishna; Sharan, Vaishali; Babu, V. C.; Yadav, Reena; Meena, G.; Murthy, N. Sitarama; Kumar; Ashoka, B. N.; Kulkarni, Ravi; Iyer, Nirmal; Radhika, D.; Kushwaha, Ankur; Balaji, K.; Nagesh, G.; Kumar, Manoj; Gaan, Dhruti Ranjan; Kulshresta, Prashanth; Agarwal, Pankaj; Sebastin, Matthew; Rajarajan, A.; Rao, S. V. S. Subba; Pandiyan; R.; Rao, K. Subba; Rao, Chaitra; Sarma, K. Suryanarayana

    2015-10-01

    The Scanning Sky Monitor (SSM) on board ASTROSAT was made operational on October 12th, 2015, the 15th day after launch (September 28th, 2015). After initial observations of the Crab Nebula, on October 14th 2015, the SSM was maneuvered for a stare at the galactic Black Hole source GRS 1915+105.

  20. Development of a low-energy and high-current pulsed neutral beam injector with a washer-gun plasma source for high-beta plasma experiments.

    Science.gov (United States)

    Ii, Toru; Gi, Keii; Umezawa, Toshiyuki; Asai, Tomohiko; Inomoto, Michiaki; Ono, Yasushi

    2012-08-01

    We have developed a novel and economical neutral-beam injection system by employing a washer-gun plasma source. It provides a low-cost and maintenance-free ion beam, thus eliminating the need for the filaments and water-cooling systems employed conventionally. In our primary experiments, the washer gun produced a source plasma with an electron temperature of approximately 5 eV and an electron density of 5 × 10(17) m(-3), i.e., conditions suitable for ion-beam extraction. The dependence of the extracted beam current on the acceleration voltage is consistent with space-charge current limitation, because the observed current density is almost proportional to the 3/2 power of the acceleration voltage below approximately 8 kV. By optimizing plasma formation, we successfully achieved beam extraction of up to 40 A at 15 kV and a pulse length in excess of 0.25 ms. Its low-voltage and high-current pulsed-beam properties enable us to apply this high-power neutral beam injection into a high-beta compact torus plasma characterized by a low magnetic field. PMID:22938291

  1. Numerical methods of diffusion coefficients calculation. Diffusion from an instant beta-source (μ=100 1/cm)

    International Nuclear Information System (INIS)

    The paper discusses a numerical method of calculating the diffusion coefficient β of the radioactive elements for the case when diffusion occurs from an instantaneous source into a semi-infinite medium. A computer program has been compiled, using which the dependence has been tabulated of the quantity (Dxt) on the ratio of the values of the integrated activity J(xsub(n), t) J(o, t)=0.95 - 0.05 with a step of 0.02 and on the value xsub(n)=0.0005=0.0500 cm with a step of 0.0005 cm for the β-radioactive elements with the radiation absorption coefficient μ=100 1/cm

  2. $\\beta$-decay study of very neutron-rich Cd isotopes with a chemically selective laser ion source

    CERN Multimedia

    2002-01-01

    Following our test measurements of N=82-84 Cd isotopes with a specifically developed laser ion source (CERN/ISC 97-16, ISC/I 22), we now propose detailed spectroscopic studies of the decay of $^{130}$Cd to $\\,^{132}\\!$Cd, and at least the determination of some gross properties of the new N=85-86 nuclides $^{133}\\!$Cd and $\\,^{134}\\!$Cd. The main nuclear-structure objective of this experiment is the identification of the energies of the single-hole (SH) proton states in $^{131}$In. Nearly all of the other single-nucleon shell-model basis energies around doubly magic $^{132}$Sn are known by now, except those $\\pi$SH in Z=49 $\\,^{131}$In. Theoretical agreement on these values has not been achieved so far. Of particular interest is the depth of the $\\pi$f$_{5/3}$ hole and the p$_{3/2}$ - p$_{1/2}$ spin-orbit splitting. A second important goal is the determination of the position of the lowest-energy 1$^+\\,$ level in $^{130}$In predominantly populated in the Gamow-Teller (GT) decay of N=82 $^{130}\\!$Cd. Apart from...

  3. Status and Performance of New Silicon Stripixel Detector for the PHENIX Experiment at RHIC Beta Source, Cosmic-rays and Proton Beam at 120 GeV

    CERN Document Server

    Nouicer, Rachid

    2009-01-01

    We are constructing a Silicon Vertex Tracker detector (VTX) for the PHENIX experiment at RHIC. Our main motivation is to enable measurements of heavy flavor production (charm and beauty) in p+p, p+d and A+A collisions. Such data will illuminate the properties of the matter created in high-energy heavy-ion collisions. The measurements also will reveal the distribution of gluons in protons from p+p collisions. The VTX detector consists of four layers of barrel detectors and covers |eta|< 1.2, and almost a 2pi in azimuth. The inner two silicon barrels consist of silicon pixel sensors; their technology accords with that of the ALICE1LHCB sensor-readout hybrid. The outer two barrels are silicon stripixel detectors with a new "spiral" design, and a single-sided sensor with 2-dimensional (X, U) readout. In this paper, we describe the silicon stripixel detector and discuss its performance, including its response to electrons from a beta source (90Sr), muons from cosmic-rays, and a 120 GeV proton beam. The results ...

  4. Study of the background of the neutrinoless double {beta} decay with the detector NEMO 2: contribution arising from the radon diffusion and internal pollution of the source {sup 214}Bi have been estimated; Etude du bruit de fond de la double-desintegration {beta} sans emission de neutrino dans le detecteur NEMO 2: contribution du radon ambiant et mesure de la pollution interne de la source en {sup 214}Bi

    Energy Technology Data Exchange (ETDEWEB)

    Mauger, F.

    1995-02-01

    The NEMO experiment is designed to understand the nature of the neutrino by studying the double beta decay of Mo-100 which is related to the Majorana neutrino effective mass. In this kind of experiment a good understanding of the different sources of background is crucial as only few events are expected per year at the required level of sensitivity. In this thesis we present the main theoretical and experimental aspects of the measurement of the neutrinoless double beta decay of Mo-100 with the prototype detector NEMO2. The goal of this study is to obtain a realistic interpretation of the few events detected at high energy in the two-electron channel as a background to neutrinoless double beta decay. In particular, the contribution arising from Bi-214 has been investigated. These events have been selected and analysed by means of the beta-alpha decays of Bi-214 into Pb-210. The events are characterized by a delayed track in the wire chamber and the corresponding signal is rather clean. The study has demonstrated the diffusion of Rn-222 into the detector and its contribution to Bi-214 pollution has been estimated. A measurement of the Bi-214 internal contamination of the source has been made as well as an estimation of the Bi-214 deposit due to Rn-222. As a result of this study it appears that, under the conditions of the NEMO2 experiment, the Bi and Rn contributions are of the same order of magnitude as the background induced at high energy by two-neutrino double beta decay. In conclusion, the backgrounds of the neutrinoless double beta decay of Mo-100 are well understood in the NEMO2 experiment leading to an extrapolation for the NEMO3 experiment. (authors).

  5. Spectral parameters modulation and source localization of blink-related alpha and low-beta oscillations differentiate minimally conscious state from vegetative state/unresponsive wakefulness syndrome.

    Directory of Open Access Journals (Sweden)

    Luca Bonfiglio

    Full Text Available Recently, the cortical source of blink-related delta oscillations (delta BROs in resting healthy subjects has been localized in the posterior cingulate cortex/precuneus (PCC/PCu, one of the main core-hubs of the default-mode network. This has been interpreted as the electrophysiological signature of the automatic monitoring of the surrounding environment while subjects are immersed in self-reflecting mental activities. Although delta BROs were directly correlated to the degree of consciousness impairment in patients with disorders of consciousness, they failed to differentiate vegetative state/unresponsive wakefulness syndrome (VS/UWS from minimally conscious state (MCS. In the present study, we have extended the analysis of BROs to frequency bands other than delta in the attempt to find a biological marker that could support the differential diagnosis between VS/UWS and MCS. Four patients with VS/UWS, 5 patients with MCS, and 12 healthy matched controls (CTRL underwent standard 19-channels EEG recordings during resting conditions. Three-second-lasting EEG epochs centred on each blink instance were submitted to time-frequency analyses in order to extract the normalized Blink-Related Synchronization/Desynchronization (nBRS/BRD of three bands of interest (low-alpha, high-alpha and low-beta in the time-window of 50-550 ms after the blink-peak and to estimate the corresponding cortical sources of electrical activity. VS/UWS nBRS/BRD levels of all three bands were lower than those related to both CTRL and MCS, thus enabling the differential diagnosis between MCS and VS/UWS. Furthermore, MCS showed an intermediate signal intensity on PCC/PCu between CTRL and VS/UWS and a higher signal intensity on the left temporo-parieto-occipital junction and inferior occipito-temporal regions when compared to VS/UWS. This peculiar pattern of activation leads us to hypothesize that resting MCS patients have a bottom-up driven activation of the task positive network

  6. Recent double beta decay results

    Energy Technology Data Exchange (ETDEWEB)

    Balysh, A. (Kurchatov Institute, 123 182 Moscow (Russian Federation)); Beck, M. (Max-Planck-Institut fuer Kernphysik, W-6900 Heidelberg (Germany)); Belyaev, S.T. (Kurchatov Institute, 123 182 Moscow (Russian Federation)); Bensch, F.; Bockholt, J. (Max-Planck-Institut fuer Kernphysik, W-6900 Heidelberg (Germany)); Demehin, A.; Gurov, A. (Kurchatov Institute, 123 182 Moscow (Russian Federation)); Heusser, G.; Hirsch, M.; Klapdor-Kleingrothaus, H.V. (Max-Planck-Institut fuer Kernphysik, W-6900 Heidelberg (Germany)); Kondratenko, I.; Lebedev, V.I. (Kurchatov Institute, 123 182 Moscow (Russian Federation)); Maier, B. (Max-Planck-Institut fuer Kernphysik, W-6900 Heidelberg (Germany)); Mueller, A. (Istituto Nazionale di Fisica Nucleare LNGS, 67010 Assergi (Italy)); Petry, F.; Piepke, A.; Strecker, H.; Voellinger, M.; Zuber, K. (Max-Planck-Institut fuer Kernphysik, W-6900 Heidelberg (Germany))

    1992-02-01

    The status and recent results of second generation [beta][beta]-experiments using isotopically enriched source materials are described. These experiments are at present the most sensitive tools to distinguish Dirac from Majorana neutrinos. The at present most advanced experimental techniques, namely the use of high-resolution calorimetric detectors and of time projection chambers are compared. New limits on the Majorana neutrino mass as well as for the Majoron-neutrino coupling are presented.

  7. Sources

    International Nuclear Information System (INIS)

    This paper discusses the sources of radiation in the narrow perspective of radioactivity and the even narrow perspective of those sources that concern environmental management and restoration activities at DOE facilities, as well as a few related sources. Sources of irritation, Sources of inflammatory jingoism, and Sources of information. First, the sources of irritation fall into three categories: No reliable scientific ombudsman to speak without bias and prejudice for the public good, Technical jargon with unclear definitions exists within the radioactive nomenclature, and Scientific community keeps a low-profile with regard to public information. The next area of personal concern are the sources of inflammation. This include such things as: Plutonium being described as the most dangerous substance known to man, The amount of plutonium required to make a bomb, Talk of transuranic waste containing plutonium and its health affects, TMI-2 and Chernobyl being described as Siamese twins, Inadequate information on low-level disposal sites and current regulatory requirements under 10 CFR 61, Enhanced engineered waste disposal not being presented to the public accurately. Numerous sources of disinformation regarding low level radiation high-level radiation, Elusive nature of the scientific community, The Federal and State Health Agencies resources to address comparative risk, and Regulatory agencies speaking out without the support of the scientific community

  8. Effect of Sertraline on Current-Source Distribution of the High Beta Frequency Band: Analysis of Electroencephalography under Audiovisual Erotic Stimuli in Healthy, Right-Handed Males

    OpenAIRE

    Lee, Seung Hyun; Hyun, Jae Seog; Kwon, Oh-Young

    2010-01-01

    Purpose The purpose of this study was to examine the cerebral changes in high beta frequency oscillations (22-30 Hz) induced by sertraline and by audiovisual erotic stimuli in healthy adult males. Materials and Methods Scalp electroencephalographies (EEGs) were conducted twice in 11 healthy, right-handed males, once before sertraline intake and again 4 hours thereafter. The EEGs included four sessions recorded sequentially while the subjects were resting, watching a music video, resting, and ...

  9. Beta contamination monitor energy response

    International Nuclear Information System (INIS)

    Beta contamination is monitored at Los Alamos National Laboratory (LANL) with portable handheld probes and their associated counters, smear counters, air-breathing continuous air monitors (CAM), personnel contamination monitors (PCM), and hand and foot monitors (HFM). The response of these monitors was measured using a set of anodized-aluminum beta sources for the five isotopes: Carbon-14, Technetium-99, Cesium-137, Chlorine-36 and Strontium/Yttrium-90. The surface emission rates of the sources are traceable to the National Institute of Standards and Technology (NIST) with a precision of one relative standard deviation equal to 1.7%. All measurements were made in reproducible geometry, mostly using aluminum source holders. All counts, significantly above background, were collected to a precision of 1% or better. The study of the hand-held probes included measurements of six air gaps from 0.76 to 26.2 mm. The energy response of the detectors is well-parameterized as a function of the average beta energy of the isotopes (C14=50 keV, Tc99=85, Cs137=188, C136=246, and Sr/Y90=934). The authors conclude that Chlorine-36 is a suitable beta emitter for routine calibration. They recommend that a pancake Geiger-Mueller (GM) or gas-proportional counter be used for primarily beta contamination surveys with an air gap not to exceed 6 mm. Energy response varies about 30% from Tc99 to Sr/Y90 for the pancake GM detector. Dual alpha/beta probes have poor to negligible efficiency for low-energy betas. The rugged anodized sources represent partially imbedded contamination found in the field and they are provided with precise, NIST-traceable, emission rates for reliable calibration

  10. Beta particle monitor for surfaces

    International Nuclear Information System (INIS)

    A beta radiation detector which is capable of reliably detecting beta radiation emitted from a surface. An electrically conductive signal collector is adjustably mounted inside an electrically conductive enclosure which may define a single large opening for placing against a surface. The adjustable mounting of the electrically conductive signal collector can be based on the distance from the surface or on the expected beta energy range. A voltage source is connected to the signal collector through an electrometer or other display means for creating an electric field between the signal collector and the enclosure. Air ions created by the beta radiation are collected and the current produced is indicated on the electrometer or other display means. 2 figs

  11. Sources

    OpenAIRE

    2015-01-01

    Sources Fondation Pablo Iglesias. Alcala de Henares. Sections : Archives privées de Manuel ArijaArchives extérieuresArchives FNJS de EspañaPrensa Archives Générales de l’Administration. Alcala de Henares. Sections : Opposition au franquismeSig. 653 Sig TOP 82/68.103-68.602.Índice de las cartas colectivas, Relaciones, Cartas al Ministro de Información de Marzo de 1965. c.662. Sources cinématographiques Filmothèque Nationale d’Espagne.NO.DO. N° 1157C. 08/03/1965.aguirre Javier, Blanco vertical....

  12. Beta-dosimetry studies at LLNL

    International Nuclear Information System (INIS)

    This paper summarizes three beta-dosimetry studies made recently at the Lawrence Livermore National Laboratory. The first study was to determine the beta-gamma exposure rates at the Los Alamos Godiva IV Critical Assembly. The beta spectra from the assembly were evaluated using absorption curves and the beta-gamma dose-rate ratios were determined at various distances from the assembly. A comparison was made of the doses determined using two types of TLD personnel dosimeters and a film badge. The readings of an Eberline RO-7 instrument and the dose rates determined by TLDs were compared. Shielding provided by various metals, gloves, and clothing were measured. The second study was to determine the beta energy response of the Eberline RO-7 instrument based on measurements made with the PTB beta sources. This study required additional calibration points for the PTB sources which were made using extrapolation chamber measurements. The third study resulted in two techniques to determine the beta energy (E/sub max/) from the readings of this-window portable survey instruments. Both techniques are based on the readings obtained using aluminium filters. One technique is for field application, requires one filter, and provides a quick estimate of the beta energy in three energy groups: 1.5 MeV. The second technique is more complex requiring measurements with two or three filters, but gives the beta energy and the approximate shape of the beta spectrum. 9 references, 6 figures

  13. Dynamic radioactive particle source

    Energy Technology Data Exchange (ETDEWEB)

    Moore, Murray E.; Gauss, Adam Benjamin; Justus, Alan Lawrence

    2012-06-26

    A method and apparatus for providing a timed, synchronized dynamic alpha or beta particle source for testing the response of continuous air monitors (CAMs) for airborne alpha or beta emitters is provided. The method includes providing a radioactive source; placing the radioactive source inside the detection volume of a CAM; and introducing an alpha or beta-emitting isotope while the CAM is in a normal functioning mode.

  14. Sources

    OpenAIRE

    2011-01-01

    A. SOURCES STATISTIQUES 1. Statistiques générales Annuaire statistique international, SDN (à partir de 1926). Mémorandum sur le commerce international et sur les balances des paiements, annuel à partir de 1927 (numéros rétrospectifs 1912-1926, 1913-1927), [3 volumes : aperçu général ; balances des paiements ; statistiques du commerce extérieur ; utilise les données nationales disponibles. Très utile]. Annuaire statistique de la France. Annuaire statistique de la Belgique. Statistiques économi...

  15. Sources

    OpenAIRE

    2013-01-01

    I–SOURCES MANUSCRITES Archivio di Stato di Roma (ASR) Presidenza dell’Annona e Grascia : bb. 67-68, Lista dei misuratori del grano, 1658-1660. bb. 352-377, Nota dei grani introdotti e venduti in Roma, 1657-1715. bb. 412-419, Ristretto delle assegne dei grani date dai mercanti, 1680-1687. b. 1470, Registro delle lettere del Prefetto dell’Annona, 1659-1660. b. 1706, Libri di entrata e uscita dei grani dell’abbondanza (Ripetta), 16581670. bb. 1930-1931, Debiti e crediti dei fornai, 1658-1660. b....

  16. Sources

    OpenAIRE

    2014-01-01

    Sources éditées : ABADAL i de VINYALS, Ramon d', Catalunya carolingia, II, Els diplomes carolingis a Catalunya, 2 vol., Barcelone, 1926-1952, cit. CC. ACHERY, D', Luc, Spicilegium sive collectio veterum aliquot scriptorum..., E. Baluze et E. Martène éd., Paris, 1723, tome 3. ALART, Bernard, Privilèges et titres relatifs aux franchises, institutions et propriétés communales de Roussillon et de Cerdagne depuis le xie siècle jusqu 'à l'an 1660... Première partie, Perpignan, 1878. ALART, Bernard,...

  17. Study of tracking detector of NEMO experiment - Simulation of the measurement of the ultra low 208Tl radioactivity in the source foils used as neutrinoless double beta decay emitters in NEMO experiment

    International Nuclear Information System (INIS)

    The purpose of NEMO3 experiment is the research of the neutrinoless double beta decay. This low energy process can sign the massive and Majorana nature of neutrino. This experiment with a very low radioactive background and containing 10 kg of enriched isotopes, studies mainly 100Mo. Installed at the Frejus underground laboratory, NEMO3 is a cylindrical detector which consists in very thin central source foils in a tracking detector made up of vertical drift cells operating in Geiger mode in a calorimeter and in a suitable shielding. This thesis is divided in two different parts. The first part is a full study of the features of the tracking detector. With a prototype composed of 9 drift cells we characterised the longitudinal and transverse reconstruction of position of the ionisation created by a LASER. With the first 3 modules under operation we used radioactive external neutron sources to measure the transverse resolution of ionisation position in a drift cell for high energy electrons. To study the vertex reconstruction on the source foil, sources of 207Bi which produced conversion electrons, were used inside the 3 modules. The second part of this thesis we show with simulations that we can measure with NEMO3 detector itself, the ultra low level of contamination in 208Tl of the source foil which comes from the natural radioactive chain of thorium. Using electron-photons channels we can obtain the 208Tl activity in the sources. With an analysis on the energy and on the time of flight of particles, NEMO3 is able to reach a sensitivity of 20μBq/kg after only 2 months of measurement. This sensitivity is the maximum 208Tl activity which we accepted for the sources in the NEMO3 proposal. (author)

  18. Scintillator based beta batteries

    Science.gov (United States)

    Rensing, Noa M.; Tiernan, Timothy C.; Shirwadkar, Urmila; O'Dougherty, Patrick; Freed, Sara; Hawrami, Rastgo; Squillante, Michael R.

    2013-05-01

    Some long-term, remote applications do not have access to conventional harvestable energy in the form of solar radiation (or other ambient light), wind, environmental vibration, or wave motion. Radiation Monitoring Devices, Inc. (RMD) is carrying out research to address the most challenging applications that need power for many months or years and which have undependable or no access to environmental energy. Radioisotopes are an attractive candidate for this energy source, as they can offer a very high energy density combined with a long lifetime. Both large scale nuclear power plants and radiothermal generators are based on converting nuclear energy to heat, but do not scale well to small sizes. Furthermore, thermo-mechanical power plants depend on moving parts, and RTG's suffer from low efficiency. To address the need for compact nuclear power devices, RMD is developing a novel beta battery, in which the beta emissions from a radioisotope are converted to visible light in a scintillator and then the visible light is converted to electrical power in a photodiode. By incorporating 90Sr into the scintillator SrI2 and coupling the material to a wavelength-matched solar cell, we will create a scalable, compact power source capable of supplying milliwatts to several watts of power over a period of up to 30 years. We will present the latest results of radiation damage studies and materials processing development efforts, and discuss how these factors interact to set the operating life and energy density of the device.

  19. COBRA - Double beta decay searches using CdTe detectors

    OpenAIRE

    Zuber, K.

    2001-01-01

    A new approach (called COBRA) for investigating double beta decay using CdTe (CdZnTe) semiconductor detectors is proposed. It follows the idea that source and detector are identical. This will allow simultaneous measurements of 5 $\\beta^-\\beta^-$ - and 4 $\\beta^+\\beta^+$ - emitters at once. Half-life limits for neutrinoless double beta decay of Cd-116 and Te-130 can be improved by more than one order of magnitude with respect to current limits and sensitivities on the effective Majorana neutr...

  20. Micro-battery Development using beta radioisotope

    International Nuclear Information System (INIS)

    Nuclear battery which use the beta radiation sources emitting the low penetration radiation energy from radioisotope can be applied as the long term (more than 10 years) micro power source in MEMS and nano components. This report describes the basic concept and principles of nuclear micro-battery and its fabrication in space and military field. In particular direct conversion method is described by investigating the electron-hole generation and recombination in p-n junction of silicon betavoltaics with beta radiation

  1. Development of a multi-electrode extrapolation chamber as a prototype of a primary standard for the realization of the unit of the absorbed dose to water for beta brachytherapy sources

    CERN Document Server

    Bambynek, M

    2002-01-01

    The prototype of a primary standard has been developed, built and tested, which enables the realization of the unit of the absorbed dose to water for beta brachytherapy sources. In the course of the development of the prototype, the recommendations of the American Association of Physicists in Medicine (AAPM) Task Group 60 (TG60) and the Deutsche Gesellschaft fuer Medizinische Physik (DGMP) Arbeitskreis 18 (AK18) were taken into account. The prototype is based on a new multi-electrode extrapolation chamber (MEC) which meets, in particular, the requirements on high spatial resolution and small uncertainty. The central part of the MEC is a segmented collecting electrode which was manufactured in the clean room center of PTB by means of electron beam lithography on a wafer. A precise displacement device consisting of three piezoelectric macrotranslators has been incorporated to move the wafer collecting electrode against the entrance window. For adjustment of the wafer collecting electrode parallel to the entranc...

  2. Levered and unlevered Beta

    OpenAIRE

    Fernandez, Pablo

    2003-01-01

    We prove that in a world without leverage cost the relationship between the levered beta ( L) and the unlevered beta ( u) is the No-costs-of-leverage formula: L = u + ( u - d) D (1 - T) / E. We also analyze 6 alternative valuation theories proposed in the literature to estimate the relationship between the levered beta and the unlevered beta (Harris and Pringle (1985), Modigliani and Miller (1963), Damodaran (1994), Myers (1974), Miles and Ezzell (1980), and practitioners) and prove that all ...

  3. Betting Against Beta

    DEFF Research Database (Denmark)

    Frazzini, Andrea; Heje Pedersen, Lasse

    .S. equities, 20 international equity markets, Treasury bonds, corporate bonds, and futures; (2) A betting-against-beta (BAB) factor, which is long leveraged low beta assets and short high-beta assets, produces significant positive risk-adjusted returns; (3) When funding constraints tighten, the return of the...

  4. Forward-Looking Betas

    DEFF Research Database (Denmark)

    Christoffersen, Peter; Jacobs, Kris; Vainberg, Gregory

    Few issues are more important for finance practice than the computation of market betas. Existing approaches compute market betas using historical data. While these approaches differ in terms of statistical sophistication and the modeling of the time-variation in the betas, they are all backward-...

  5. Dosimetry of low-energy beta radiation

    Energy Technology Data Exchange (ETDEWEB)

    Borg, J.

    1996-08-01

    Useful techniques and procedures for determination of absorbed doses from exposure in a low-energy {beta} radiation field were studied and evaluated in this project. The four different techniques included were {beta} spectrometry, extrapolation chamber dosimetry, Monte Carlo (MC) calculations, and exoelectron dosimetry. As a typical low-energy {beta} radiation field a moderated spectrum from a {sup 14}C source (E{sub {beta}},{sub max} =156 keV) was chosen for the study. The measured response of a Si(Li) detector to photons (bremsstrahlung) showed fine agreement with the MC calculated photon response, whereas the difference between measured and MC calculated responses to electrons indicates an additional dead layer thickness of about 12 {mu}m in the Si(Li) detector. The depth-dose profiles measured with extrapolation chambers at two laboratories agreed very well, and it was confirmed that the fitting procedure previously reported for {sup 147}Pm depth-dose profiles is also suitable for {beta} radiation from {sup 14}C. An increasing difference between measured and MC calculated dose rates for increasing absorber thickness was found, which is explained by limitations of the EGS4 code for transport of very low-energy electrons (below 10-20 keV). Finally a study of the thermally stimulated exoelectron emission (TSEE) response of BeO thin film dosemeters to {beta} radiation for radiation fields with maximum {beta} energies ranging from 67 keV to 2.27 MeV is reported. For maximum {beta} energies below approximately 500 keV, a decrease in the response amounting to about 20% was observed. It is thus concluded that a {beta} dose higher than about 10 {mu}Gy can be measured with these dosemeters to within 0 to -20% independently of the {beta}energy for E{sub {beta}},{sub max} values down to 67 keV. (au) 12 tabs., 38 ills., 71 refs.

  6. Transforming growth factor beta 1 (TGF-beta 1) induced neutrophil recruitment to synovial tissues: implications for TGF-beta-driven synovial inflammation and hyperplasia

    International Nuclear Information System (INIS)

    We have studied the consequences of introducing human recombinant transforming growth factor beta 1 (hrTGF-beta 1) into synovial tissue of the rat, to begin to better understand the significance of the fact that biologically active TGF-beta is found in human arthritic synovial effusions. Within 4-6 h after the intra-articular injection of 1 microgram of hrTGF-beta 1 into rat knee joints, extensive recruitment of polymorphonuclear leukocytes (PMNs) was observed. Cytochemistry and high resolution histological techniques were used to quantitate the influx of PMNs, which peaked 6 h post-injection. In a Boyden chamber assay, hrTGF-beta 1 at 1-10 fg/ml elicited a chemotactic response from PMNs greater in magnitude than that evoked by FMLP, establishing that TGF-beta 1 is an effective chemotactic agent for PMNs in vitro as well as in vivo. That PMNs may represent an important source of TGF-beta in inflammatory infiltrates was strongly suggested by a demonstration that stored TGF-beta 1 was secreted during phorbol myristate acetate-stimulated degranulation in vitro. Acid/ethanol extracts of human PMNs assayed by ELISA contained an average of 355 ng of TGF/beta 1 per 10(9) cells potentially available for secretion during degranulation of PMNs. [3H]Thymidine incorporation in vivo and autoradiography of tissue sections revealed that widespread cell proliferation was triggered by TGF-beta 1 injection. Synovial lining cells and cells located deep within the subsynovial connective tissue were identified as sources of at least some of the new cells that contribute to TGF-beta 1-induced hyperplasia. Our results demonstrate that TGF-beta is capable of exerting pathogenic effects on synovial tissue and that PMNs may represent a significant source of the TGF-beta present in synovial effusions

  7. Search for $\\beta^+$EC and ECEC processes in $^{112}$Sn and $\\beta^-\\beta^-$ decay of $^{124}$Sn to the excited states of $^{124}$Te

    CERN Document Server

    Barabash, A S; Nachab, A; Konovalov, S I; Vanyushin, I A; Umatov, V I

    2008-01-01

    Limits on $\\beta^+$EC and ECEC processes in $^{112}$Sn and on $\\beta^-\\beta^-$ decay of $^{124}$Sn to the excited states of $^{124}$Te have been obtained using a 380 cm$^3$ HPGe detector and an external source consisting of natural tin. A limit with 90% C.L. on the $^{112}$Sn half-life of $0.92\\times 10^{20}$ y for the ECEC(0$\

  8. Abattoirs as non-hospital source of extended spectrum beta lactamase producers: confirmed by the double disc synergy test and characterized by matrix-assisted laser desorption/ionization time of flight mass spectrometry.

    Directory of Open Access Journals (Sweden)

    Moses Nkechukwu Ikegbunam

    Full Text Available In this study, the presence of extended spectrum beta lactamase (ESBL producing organisms in abattoirs, a non-hospital community was investigated. The presence of ESBL-producing phenotypes was confirmed by the Double Disc Synergy Test (DDST. Out of the 99 isolates screened for ESBL, 28 (28.3% were confirmed positive. The positive isolates were characterised by using Matrix-Assisted Laser Desorption/Ionization Time of flight Mass Spectrometry. 50% of the isolates were Pseudomonas spp., the rest were different species of Acinetobacter, Stenotrophomonas and Achromobacter. Pseudomonas monteilli and Pseudomonas putida were the most occurring in the intestine. The entire positive ESBL producers were subjected to plasmid curing to ascertain the location of the resistant marker. The result of the plasmid curing indicated that the resistant genes were chromosomally borne. The findings have therefore established the presence of ESBL producing organisms in the gut of animals from abattoirs and the table were the meat are sold, and its rate of occurrence is comparable to hospital ICUs. Abattoir communities could probably be a source of human infection with ESBL expressing pathogens and possible transfer to non-ESBL producers.

  9. Properties of a commercial extrapolation chamber in beta radiation fields

    International Nuclear Information System (INIS)

    A commercial extrapolation chamber (PTW, Germany) was tested in different beta radiation fields and its properties investigated. Its usefulness for beta radiation calibration and dosimetry was demonstrated. The Beta Secondary Standard setup of the IPEN calibration laboratory was utilized. This system, developed by the Physikalisch-Tecknische Bundesanstalt, Brunswick (Germany) and manufactured by Buchler and Co., consists of a source stand, a control unit with timer and four interchangeable beta sources: 90Sr-90Y (1850 and 74 MBq), 204Tl (18,5 MBq) ionization current detection. The variable volume ionization chamber of cylindrical form is provided with different collecting electrodes of tissue equivalent material and Mylar entrance windows of different thickesses

  10. Eukaryotic beta-alanine synthases are functionally related but have a high degree of structural diversity

    DEFF Research Database (Denmark)

    Gojkovic, Zoran; Sandrini, Michael; Piskur, Jure

    2001-01-01

    beta -Alanine synthase (EC 3.5.1.6), which catalyzes the final step of pyrimidine catabolism, has only been characterized in mammals. A Saccharomyces kluyveri pyd3 mutant that is unable to grow on N-carbamy-beta -alanine as the sole nitrogen source and exhibits diminished beta -alanine synthase a......-carbamyl-beta -alanine, but not by uracil. This wrork establishes S. kluyveri as a model organism for studying pyrimidine degradation and beta -alanine production in eukaryotes....

  11. Beta Beams for Precision Measurements of Neutrino Oscillation Parameters

    CERN Document Server

    Wildner, E; Hansen, C; De Melo Mendonca, T; Stora, T; Damjanovic, S; Payet, J; Chancé, A; Zorin, V; Izotov, I; Rasin, S; Sidorov, A; Skalyga, V; De Angelis, G; Prete, G; Cinausero, M; Kravchuk, V; Gramegna, F; Marchi, T; Collazuol, G; Mezzetto, M; Delbar, T; Loiselet, M; Keutgen, T; Mitrofanov, S; Burt, G; Dexter, A; Lamy, T; Latrasse, L; Marie-Jeanne, M; Sortais, P; Thuillier, T; Debray, F; Trophime, C; Hass, M; Hirsh, T; Berkovits, D; Stahl, A; Vardaci, E; Di Nitto, A; Brondi, A; La Rana, G; Moro, R; De Rosa, G; Palladino, V

    2012-01-01

    Neutrino oscillations have implications for the Standard Model of particle physics. The CERN Beta Beam has outstanding capabilities to contribute to precision measurements of the parameters governing neutrino oscillations. The FP7 collaboration EUROnu (2008-2012) is a design study that will review three facilities (Super-Beams, Beta Beams and Neutrino Factories) and perform a cost assessment that, coupled with the physics performance, will give means to the European research authorities to make decisions on future European neutrino oscillation facilities. ”Beta Beams” produce collimated pure electron (anti)neutrinos by accelerating beta active ions to high energies and having them decay in a storage ring. Using existing machines and infrastructure is an advantage for the cost evaluation; however, this choice is also constraining the Beta Beams. Recent work to make the Beta Beam facility a solid option will be described: production of Beta Beam isotopes, the 60 GHz pulsed ECR source development, integratio...

  12. Koedam {beta} factors revisited

    Energy Technology Data Exchange (ETDEWEB)

    Lawler, J.E. [Physics Department, University of Wisconsin, Madison, WI (United States); Doughty, D.A. [Perkin-Elmer Optoelectronics, Santa Clara, CA (United States); Lister, G.G. [OSRAM SYLVANIA Inc., Beverly, MA (United States)

    2002-07-21

    A Koedam {beta} factor makes it possible to compute the total output power in line radiation from a positive column discharge using a single radiance measurement normal to an aperture in the wall. The results of analytic derivations of {beta} factors are presented for columns with uniform ({beta}=1.0) and parabolic ({beta}=0.75) excitation rates per unit volume and with negligible opacity. A Monte Carlo code for simulating radiation trapping with a spatially uniform density of absorbing atoms is then used to determine {beta} factors as a function of opacity. The code includes partial frequency redistribution and a Voigt line shape with radiative broadening, resonance collisional broadening, and Doppler broadening. The resulting {beta} factors are found to be nearly independent of opacity over a wide range of column radii for spectral line shapes dominated by Doppler broadening or by resonance collisional broadening. Additional Monte Carlo simulations are used to study {beta} factors as a function of a non-uniform density of absorbing atoms from radial cataphoresis with line shapes dominated by Doppler broadening, foreign gas broadening, and resonance collisional broadening. Radial cataphoresis is found to increase {beta} factors in all cases. Geometrical effects, refraction, and imperfect transmission at the glass wall are studied and found to decrease {beta} factors. (author)

  13. Beta-energy averaging and beta spectra

    International Nuclear Information System (INIS)

    A simple yet highly accurate method for approximately calculating spectrum-averaged beta energies and beta spectra for radioactive nuclei is presented. This method should prove useful for users who wish to obtain accurate answers without complicated calculations of Fermi functions, complex gamma functions, and time-consuming numerical integrations as required by the more exact theoretical expressions. Therefore, this method should be a good time-saving alternative for investigators who need to make calculations involving large numbers of nuclei (e.g., fission products) as well as for occasional users interested in restricted number of nuclides. The average beta-energy values calculated by this method differ from those calculated by ''exact'' methods by no more than 1 percent for nuclides with atomic numbers in the 20 to 100 range and which emit betas of energies up to approximately 8 MeV. These include all fission products and the actinides. The beta-energy spectra calculated by the present method are also of the same quality

  14. Modeling the transmission of beta rays through thin foils in planar geometry.

    Science.gov (United States)

    Stanga, D; De Felice, P; Keightley, J; Capogni, M; Ionescu, E

    2016-01-01

    This paper is concerned with the modeling of the transmission of beta rays through thin foils in planar geometry based on the plane source concept, using Monte Carlo simulation of electron transport and least squares fitting. Applications of modeling results for calculating the efficiency of large-area beta sources, transmission coefficient of beta rays through thin foils and the beta detection efficiency of large-area detectors used in surface contamination measurements are also presented. PMID:26524407

  15. Evaluation of the instrument correction factors need in beta dosimetry

    International Nuclear Information System (INIS)

    A wide variety of portable survey instruments using Geiger-Mueller (GM) detectors, ionization chambers, or scintillation detectors exists for the measurement of gamma dose rates. Generally, the same instruments are used for beta monitoring, but the beta response of these instruments has been secondary to their development, calibration, and use; information on the beta response is difficult to obtain and seldom provided by the manufacturer. This paper summarizes observations on energy, angular, and source-geometry response of survey instruments

  16. Double beta decay experiments

    OpenAIRE

    Barabash, A. S.

    2011-01-01

    The present status of double beta decay experiments is reviewed. The results of the most sensitive experiments are discussed. Proposals for future double beta decay experiments with a sensitivity to the $$ at the level of (0.01--0.1) eV are considered.

  17. Negative Beta Encoder

    CERN Document Server

    Kohda, Tohru; Aihara, Kazuyuki

    2008-01-01

    A new class of analog-digital (A/D), digital-analog (D/A) converters as an alternative to conventional ones, called $\\beta$-encoder, has been shown to have exponential accuracy in the bit rates while possessing self-correction property for fluctuations of amplifier factor $\\beta$ and quantizer threshold $\

  18. Betting against Beta

    DEFF Research Database (Denmark)

    Frazzini, Andrea; Heje Pedersen, Lasse

    2014-01-01

    We present a model with leverage and margin constraints that vary across investors and time. We find evidence consistent with each of the model's five central predictions: (1) Because constrained investors bid up high-beta assets, high beta is associated with low alpha, as we find empirically for...

  19. Rapid synthesis of beta zeolites

    Energy Technology Data Exchange (ETDEWEB)

    Fan, Wei; Chang, Chun -Chih; Dornath, Paul; Wang, Zhuopeng

    2015-08-18

    The invention provides methods for rapidly synthesizing heteroatom containing zeolites including Sn-Beta, Si-Beta, Ti-Beta, Zr-Beta and Fe-Beta. The methods for synthesizing heteroatom zeolites include using well-crystalline zeolite crystals as seeds and using a fluoride-free, caustic medium in a seeded dry-gel conversion method. The Beta zeolite catalysts made by the methods of the invention catalyze both isomerization and dehydration reactions.

  20. Beta adrenergic receptors in human cavernous tissue

    International Nuclear Information System (INIS)

    Beta adrenergic receptor binding was performed with 125I iodocyanopindolol on human cavernous tissue membrane fractions from normal tissue and transsexual procedures obtained postoperatively, as well as from postmortem sources. Isotherm binding studies on normal fresh tissues indicated that the receptor density was 9.1 fmoles/mg. with a KD of 23 pM. Tissue stored at room temperature for 4 to 6 hours, then at 4C in saline solution for 19 to 20 hours before freezing showed no significant changes in receptor density or affinity, and provided evidence for the stability of postmortem tissue obtained within the same time period. Beta receptor density of 2 cavernous preparations from transsexual procedures was not significantly different from normal control tissues, and showed that high concentrations of estrogen received by these patients had no effect on beta adrenergic receptor density. Displacement of 125iodocyanopindolol by 5 beta adrenergic agents demonstrated that 1-propranolol had the greatest affinity followed by ICI 118,551, zinterol, metoprolol and practolol. When the results of these displacement studies were subjected to Scatfit, non- linear regression line analysis, a single binding site was described. Based on the relative potency of the selective beta adrenergic agents it appears that these receptors were of the beta 2 subtype

  1. Beta adrenergic receptors in human cavernous tissue

    Energy Technology Data Exchange (ETDEWEB)

    Dhabuwala, C.B.; Ramakrishna, C.V.; Anderson, G.F.

    1985-04-01

    Beta adrenergic receptor binding was performed with /sup 125/I iodocyanopindolol on human cavernous tissue membrane fractions from normal tissue and transsexual procedures obtained postoperatively, as well as from postmortem sources. Isotherm binding studies on normal fresh tissues indicated that the receptor density was 9.1 fmoles/mg. with a KD of 23 pM. Tissue stored at room temperature for 4 to 6 hours, then at 4C in saline solution for 19 to 20 hours before freezing showed no significant changes in receptor density or affinity, and provided evidence for the stability of postmortem tissue obtained within the same time period. Beta receptor density of 2 cavernous preparations from transsexual procedures was not significantly different from normal control tissues, and showed that high concentrations of estrogen received by these patients had no effect on beta adrenergic receptor density. Displacement of /sup 125/iodocyanopindolol by 5 beta adrenergic agents demonstrated that 1-propranolol had the greatest affinity followed by ICI 118,551, zinterol, metoprolol and practolol. When the results of these displacement studies were subjected to Scatfit, non- linear regression line analysis, a single binding site was described. Based on the relative potency of the selective beta adrenergic agents it appears that these receptors were of the beta 2 subtype.

  2. Beta-carotene

    Science.gov (United States)

    ... and deterioration of the lining of the mouth (oral mucositis). Taking beta-carotene by mouth doesn’t appear to prevent the development of oral mucositis during radiation therapy or chemotherapy. Pancreatic cancer. Taking ...

  3. Neutrinoless double beta decay

    International Nuclear Information System (INIS)

    The physics potential of neutrinoless double beta decay is discussed. Furthermore, experimental considerations as well as the current status of experiments are presented. Finally, an outlook towards the future, work on nuclear matrix elements and alternative processes is given. (author)

  4. Neutrinoless double beta decay

    Indian Academy of Sciences (India)

    Kai Zuber

    2012-10-01

    The physics potential of neutrinoless double beta decay is discussed. Furthermore, experimental considerations as well as the current status of experiments are presented. Finally, an outlook towards the future, work on nuclear matrix elements and alternative processes is given.

  5. Beta attenuation transmission system (BATS)

    International Nuclear Information System (INIS)

    The beta attenuation transmission system (BATS) is an automated radiation gauge designed for quantitative measurement of component thickness in explosive detonators. The BATS was designed and built by Group M-1, the Nondestructive Testing Group, of the Los Alamos Scientific Laboratory to measure the areal thickness, in mg/cm2, of a cylinder of high explosive (HE) enclosed within a plastic holder. The problem is to determine the density of the HE. A 90Sr source is collimated by a 0.25 x 1.59-mm slit, and the transmitted beta-particle flux is detected by a plastic scintillator, coupled to a photomultiplier tube. The detonator is transported through the radiation beam by a leadscrew, ballnut, stepping-motor combination. Continuous analog position data are available, derived from the output from a linear-actuated potentiometer attached to the scanner. A linear electrometer amplifies the detected signal, which is then integrated for a preselected time, to obtain the desired statistical accuracy. A microprocessor (μP) is used to control the scanner position and to make the data readings at the assigned positions. The data are stored, and, at the completion of the scan, are processed into the desired format. The final answer is displayed to the operator or output to a peripheral device for permanent record. The characteristics of the radiation source, the collimator, the signal detection and conditioning, and the final results are described in detail. The scanner and the microprocessor control system are briefly outlined

  6. Beta attenuation transmission system (BATS)

    Energy Technology Data Exchange (ETDEWEB)

    Hagan, R.C.; Fullbright, H.J.

    1977-01-01

    The beta attenuation transmission system (BATS) is an automated radiation gauge designed for quantitative measurement of component thickness in explosive detonators. The BATS was designed and built by Group M-1, the Nondestructive Testing Group, of the Los Alamos Scientific Laboratory to measure the areal thickness, in mg/cm/sup 2/, of a cylinder of high explosive (HE) enclosed within a plastic holder. The problem is to determine the density of the HE. A /sup 90/Sr source is collimated by a 0.25 x 1.59-mm slit, and the transmitted beta-particle flux is detected by a plastic scintillator, coupled to a photomultiplier tube. The detonator is transported through the radiation beam by a leadscrew, ballnut, stepping-motor combination. Continuous analog position data are available, derived from the output from a linear-actuated potentiometer attached to the scanner. A linear electrometer amplifies the detected signal, which is then integrated for a preselected time, to obtain the desired statistical accuracy. A microprocessor (..mu..P) is used to control the scanner position and to make the data readings at the assigned positions. The data are stored, and, at the completion of the scan, are processed into the desired format. The final answer is displayed to the operator or output to a peripheral device for permanent record. The characteristics of the radiation source, the collimator, the signal detection and conditioning, and the final results are described in detail. The scanner and the microprocessor control system are briefly outlined.

  7. [High beta tokamak research

    International Nuclear Information System (INIS)

    Our activities on High Beta Tokamak Research during the past 20 months of the present grant period can be divided into six areas: reconstruction and modeling of high beta equilibria in HBT; measurement and analysis of MHD instabilities observed in HBT; measurements of impurity transport; diagnostic development on HBT; numerical parameterization of the second stability regime; and conceptual design and assembly of HBT-EP. Each of these is described in some detail in the sections of this progress report

  8. High beta multipoles

    International Nuclear Information System (INIS)

    Multipoles are being employed as devices to study fusion issues and plasma phenomena at high values of beta (plasma pressure/magnetic pressure) in a controlled manner. Due to their large volume, low magnetic field (low synchrotron radiation) region, they are also under consideration as potential steady state advanced fuel (low neutron yield) reactors. Present experiments are investigating neoclassical (bootstrap and Pfirsch-Schlueter) currents and plasma stability at extremely high beta

  9. Autoregressive conditional beta

    OpenAIRE

    Yunmi Kim

    2012-01-01

    The capital asset pricing model provides various predictions about equilibrium expected returns on risky assets. One key prediction is that the risk premium on a risky asset is proportional to the nondiversifiable market risk measured by the asset's beta coefficient. This paper proposes a new method for estimating and drawing inferences from a time-varying capital asset pricing model. The proposed method, which can be considered a vector autoregressive model for multiple beta coefficients, is...

  10. A Novel Dimeric Inhibitor Targeting Beta2GPI in Beta2GPI/Antibody Complexes Implicated in Antiphospholipid Syndrome

    Energy Technology Data Exchange (ETDEWEB)

    A Kolyada; C Lee; A De Biasio; N Beglova

    2011-12-31

    {beta}2GPI is a major antigen for autoantibodies associated with antiphospholipid syndrome (APS), an autoimmune disease characterized by thrombosis and recurrent pregnancy loss. Only the dimeric form of {beta}2GPI generated by anti-{beta}2GPI antibodies is pathologically important, in contrast to monomeric {beta}2GPI which is abundant in plasma. We created a dimeric inhibitor, A1-A1, to selectively target {beta}2GPI in {beta}2GPI/antibody complexes. To make this inhibitor, we isolated the first ligand-binding module from ApoER2 (A1) and connected two A1 modules with a flexible linker. A1-A1 interferes with two pathologically important interactions in APS, the binding of {beta}2GPI/antibody complexes with anionic phospholipids and ApoER2. We compared the efficiency of A1-A1 to monomeric A1 for inhibition of the binding of {beta}2GPI/antibody complexes to anionic phospholipids. We tested the inhibition of {beta}2GPI present in human serum, {beta}2GPI purified from human plasma and the individual domain V of {beta}2GPI. We demonstrated that when {beta}2GPI/antibody complexes are formed, A1-A1 is much more effective than A1 in inhibition of the binding of {beta}2GPI to cardiolipin, regardless of the source of {beta}2GPI. Similarly, A1-A1 strongly inhibits the binding of dimerized domain V of {beta}2GPI to cardiolipin compared to the monomeric A1 inhibitor. In the absence of anti-{beta}2GPI antibodies, both A1-A1 and A1 only weakly inhibit the binding of pathologically inactive monomeric {beta}2GPI to cardiolipin. Our results suggest that the approach of using a dimeric inhibitor to block {beta}2GPI in the pathological multivalent {beta}2GPI/antibody complexes holds significant promise. The novel inhibitor A1-A1 may be a starting point in the development of an effective therapeutic for antiphospholipid syndrome.

  11. Survey instrument response to beta radiations

    International Nuclear Information System (INIS)

    Available survey instruments do not have the beta measurement characteristics needed for accurate dose rate assessments. Such instruments have severe angular and energy dependence. In addition, beta measurements often require corrections for the source geometry response of the detector to permit accurate assessments. Studies were performed to characterize present instruments and to determine optimum characteristics for a field instrument. Results of the studies were used to specify and procure an instrument with improved characteristics. The purpose of this paper is to describe the results of the studies and the design of the instrument

  12. Survey instrument response to beta radiations

    International Nuclear Information System (INIS)

    Available survey instruments do not have the beta measurement characteristics needed for accurate dose rate assessments. Such instruments have severe angular and energy dependence. In addition, beta measurements often require corrections for the source geometry response of the detector to permit accurate assessments. Studies were performed to characterize present instruments and to determine optimum characteristics for a field instrument. Results of the studies were used to specify and procure an instrument with improved characteristics. The purpose of this paper is to describe the results of the studies and the design of the instrument. 6 refs., 6 figs., 4 tabs

  13. T violation in radiative $\\beta$ decay and electric dipole moments

    CERN Document Server

    Dekens, W G

    2015-01-01

    In radiative $\\beta$ decay, $T$ violation can be studied through a spin-independent $T$-odd correlation. We consider contributions to this correlation by beyond the standard model (BSM) sources of $T$-violation, arising above the electroweak scale. At the same time such sources, parametrized by dimension-6 operators, can induce electric dipole moments (EDMs). As a consequence, the manifestations of the $T$-odd BSM physics in radiative $\\beta$ decay and EDMs are not independent. Here we exploit this connection to show that current EDM bounds already strongly constrain the spin-independent $T$-odd correlation in radiative $\\beta$ decay.

  14. Double beta decay experiments

    International Nuclear Information System (INIS)

    The great sensitivity of double beta decay to neutrino mass and right handed currents has motivated many new and exciting attempts to observe this elusive nuclear phenomenon directly. Experiments in operation and other coming on line in the next one or two years are expected to result in order-of-magnitude improvements in detectable half lives for both the two-neutrino and no-neutrino modes. A brief history of double beta decay experiments is presented together with a discussion of current experimental efforts, including a gas filled time projection chamber being used to study selenium-82. (author)

  15. Plasma beta HCG determination

    International Nuclear Information System (INIS)

    There are three important indications for the early diagnosis of pregnancy through the determination of the beta sub-unit of chorionic gonadotrophin using radioimmunoassay: 1) some patient's or doctor's anxiety to discover the problem; 2) when it will be necessary to employ diagnostic or treatment procedures susceptible to affect the ovum; and 3) in the differential diagnosis of amenorrhoea, uterine hemorrhage and abdominal tumors. Other user's are the diagnosis of missed absortion, and the diagnosis and follow-up of chrorioncarcinoma. The AA. studied 200 determinations of plasma beta-HCG, considering the main difficulties occuring in the clinical use of this relevant laboratory tool in actual Obstetrics. (author)

  16. Beta and Gamma Gradients

    DEFF Research Database (Denmark)

    Løvborg, Leif; Gaffney, C. F.; Clark, P. A.;

    1985-01-01

    Experimental and/or theoretical estimates are presented concerning, (i) attenuation within the sample of beta and gamma radiation from the soil, (ii) the gamma dose within the sample due to its own radioactivity, and (iii) the soil gamma dose in the proximity of boundaries between regions of...... differing radioactivity. It is confirmed that removal of the outer 2 mm of sample is adequate to remove influence from soil beta dose and estimates are made of the error introduced by non-removal. Other evaluations include variation of the soil gamma dose near the ground surface and it appears that the...

  17. Problems at the Development of personal Beta-particle dosemeters-Beta Particle dosemeters-

    International Nuclear Information System (INIS)

    Workplaces at which beta radiation might significantly contribute to the doses to the extremities are increasingly found in radiation therapy, radiation source production and nuclear plants. for the measurement of the individual beta-particle dose, personal dosemeters for fingers, arms and legs are needed. Intercomparison measurements organised from 1996 by the PTB have shown that some dosemeter types based on TLD are suitable for this purpose and can be used as legal dosemeters for both photon and beta radiation. Also, some electronic personal photon dosemeters are investigated in beta radiation fields. it turned out that a few types are also sensitive to beta radiation and measure the personal dose equivalent rate to the skin with a low energy dependence. Only their wearing position is by far not optimal foe extremity dosimetry because they are worn on the chest. Advantages and disadvantages are discussed. The characterisation of workplaces is carried out by measuring dose profiles using area dosemeters. Investigations performed with several commercial types of these dosemeters furnish information about the selection of the suitable measuring device and its correct practical use. the development of improved dosemeters has to towards smaller detectors and higher sensitivity. Personal dosemeters have to be robust and acceptable to the user, which generally is not achieved for beta extremity dosemeters. It is an additional problem that even such dosemeters cannot always be worn in the appropriate place. (Author)

  18. Abattoirs as Non-Hospital Source of Extended Spectrum Beta Lactamase Producers: Confirmed by the Double Disc Synergy Test and Characterized by Matrix-Assisted Laser Desorption/Ionization Time of Flight Mass Spectrometry

    OpenAIRE

    Ikegbunam, Moses Nkechukwu; Anagu, Linda Onyeka; Ifeanyi R Iroha; Ejikeugwu, Chika Ebiye; Esimone, Charles Okey

    2014-01-01

    In this study, the presence of extended spectrum beta lactamase (ESBL) producing organisms in abattoirs, a non-hospital community was investigated. The presence of ESBL-producing phenotypes was confirmed by the Double Disc Synergy Test (DDST). Out of the 99 isolates screened for ESBL, 28 (28.3%) were confirmed positive. The positive isolates were characterised by using Matrix-Assisted Laser Desorption/Ionization Time of flight Mass Spectrometry. 50% of the isolates were Pseudomonas spp., the ...

  19. Evaluation of neutrino masses from $m_{\\beta\\beta}$ values

    CERN Document Server

    Khrushchov, V V

    2008-01-01

    A neutrino mass matrix is considered under conditions of the CP invariance and the negligible reactor mixing $\\theta_{13}$ angle. Absolute mass values for three neutrinos are evaluated in normal and inverted hierarchy spectra on the ground of data for oscillation mixing neutrino parameters and effective neutrino mass entering into a probability of neutrinoless two beta decay $m_{\\beta\\beta}$ values.

  20. Low-beta structures

    OpenAIRE

    M. Vretenar(CERN, Geneva, Switzerland)

    2012-01-01

    'Low-beta' radio-frequency accelerating structures are used in the sections of a linear accelerator where the velocity of the particle beam increases with energy. The requirement for space periodicity to match the increasing particle velocity led to the development of a large variety of structures, both normal and superconducting, which are described in this lecture.

  1. Applied Beta Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Rich, B.L.

    1986-01-01

    Measurements of beta and/or nonpenetrating exposure results is complicated and past techniques and capabilities have resulted in significant inaccuracies in recorded results. Current developments have resulted in increased capabilities which make the results more accurate and should result in less total exposure to the work force. Continued development of works in progress should provide equivalent future improvements.

  2. Roughing up Beta

    DEFF Research Database (Denmark)

    Bollerslev, Tim; Li, Sophia Zhengzi; Todorov, Viktor

    Motivated by the implications from a stylized equilibrium pricing framework, we investigate empirically how individual equity prices respond to continuous, or \\smooth," and jumpy, or \\rough," market price moves, and how these different market price risks, or betas, are priced in the cross-section...

  3. Neutrinoless Double Beta Decay

    CERN Document Server

    Päs, Heinrich

    2015-01-01

    We review the potential to probe new physics with neutrinoless double beta decay $(A,Z) \\to (A,Z+2) + 2 e^-$. Both the standard long-range light neutrino mechanism as well as short-range mechanisms mediated by heavy particles are discussed. We also stress aspects of the connection to lepton number violation at colliders and the implications for baryogenesis.

  4. Applied Beta Dosimetry

    International Nuclear Information System (INIS)

    Measurements of beta and/or nonpenetrating exposure results is complicated and past techniques and capabilities have resulted in significant inaccuracies in recorded results. Current developments have resulted in increased capabilities which make the results more accurate and should result in less total exposure to the work force. Continued development of works in progress should provide equivalent future improvements

  5. Interferon Beta-1b Injection

    Science.gov (United States)

    Interferon beta-1b injection is used to reduce episodes of symptoms in patients with relapsing-remitting (course ... and problems with vision, speech, and bladder control). Interferon beta-1b is in a class of medications ...

  6. Genetics Home Reference: beta thalassemia

    Science.gov (United States)

    ... for Disease Control and Prevention Centre for Genetics Education (Australia) Cold Spring Harbor Laboratory: Your Genes Your Health Disease InfoSearch: Beta Thalassemia Genomics Education Programme (UK) MalaCards: dominant beta-thalassemia Merck Manual ...

  7. Beta gets better with age

    OpenAIRE

    Tomunen, Tuomas

    2015-01-01

    The objective of my thesis is to study the cause for the low beta anomaly, which is an observation that the high beta stocks perform poorly relative to the low beta stocks. Based on earlier findings, I hypothesize that if a stock has high investor attention, its price overreacts to market-wide shocks, which results in a positive measurement error in its beta. Simultaneously, high attention causes overpricing, because the stock overreacts more often to positive shocks than to negat...

  8. Misleading Betas: An Educational Example

    Science.gov (United States)

    Chong, James; Halcoussis, Dennis; Phillips, G. Michael

    2012-01-01

    The dual-beta model is a generalization of the CAPM model. In the dual-beta model, separate beta estimates are provided for up-market and down-market days. This paper uses the historical "Anscombe quartet" results which illustrated how very different datasets can produce the same regression coefficients to motivate a discussion of the…

  9. Precision mass measurements utilizing beta endpoints

    International Nuclear Information System (INIS)

    A technique for precise determination of beta endpoints with an intrinsic germanium detector has been developed. The energy calibration was derived from γ-ray photopeak measurements. This analysis procedure has been checked with a 27Si source produced in a (p,n) reaction on an 27Al target and subsequently applied to mass separated samples of 76Rb, 77Rb and 78Rb. Results indicate errors < 50 keV are obtainable. (orig.)

  10. High energy beta rays and vectors of Bilharzia and Fasciola

    International Nuclear Information System (INIS)

    Preliminary investigations of the effects of high energy beta rays on Lymnea natalensis, the snail vector of Schistosoma haematobium have been conducted. Results show that in both stream and tap water, about 70% of the snails die when irradiated for up to 18 hours using a 15m Ci Sr-90 beta source. The rest of the snails die without further irradiation in 24 hours. It may then be possible to control the vectors of Bilharzia and Fasciola by using both the direct and indirect effects of high energy betas. (author)

  11. High energy beta rays and vectors of Bilharzia and Fasciola

    Energy Technology Data Exchange (ETDEWEB)

    Fletcher, J.J.; Akpa, T.C.; Dim, L.A.; Ogunsusi, R.

    1988-01-01

    Preliminary investigations of the effects of high energy beta rays on Lymnea natalensis, the snail vector of Schistosoma haematobium have been conducted. Results show that in both stream and tap water, about 70% of the snails die when irradiated for up to 18 hours using a 15m Ci Sr-90 beta source. The rest of the snails die without further irradiation in 24 hours. It may then be possible to control the vectors of Bilharzia and Fasciola by using both the direct and indirect effects of high energy betas.

  12. Possible background reductions in double beta decay experiments

    CERN Document Server

    Arnold, R; Baker, J; Barabash, A S; Bing, O; Brudanin, V B; Caffrey, A J; Caurier, E; Errahmane, K; Etienvre, A I; Guyonnet, J L; Hubert, F; Hubert, P; Jollet, C; Jullian, S; Kochetov, O I; Kovalenko, V; Lalanne, D; Leccia, F; Longuemare, C; Marquet, C; Mauger, F; Nicholson, H W; Ohsumi, H; Piquemal, F; Reyss, J L; Sarazin, X; Shitov, Yu P; Simard, L C; Stekl, I; Suhonen, J; Sutton, C S; Szklarz, G; Timkin, V; Tretyak, V I; Umatov, V I; Vàla, L; Vanyushin, I A; Vasilyev, V; Vorobel, V; Vylov, T D; Hubert, Ph.; Marquet, Ch.; Shitov, Yu.; Vylov, Ts.

    2003-01-01

    The background induced by radioactive impurities of $^{208}\\rm Tl$ and $^{214}\\rm Bi$ in the source of the double beta experiment NEMO-3 has been investigated. New methods of data analysis which decrease the background from the above mentioned contamination are identified. The techniques can also be applied to other double beta decay experiments capable of measuring independently the energies of the two electrons.

  13. Beta-thalassemia

    Directory of Open Access Journals (Sweden)

    Origa Raffaella

    2010-05-01

    Full Text Available Abstract Beta-thalassemias are a group of hereditary blood disorders characterized by anomalies in the synthesis of the beta chains of hemoglobin resulting in variable phenotypes ranging from severe anemia to clinically asymptomatic individuals. The total annual incidence of symptomatic individuals is estimated at 1 in 100,000 throughout the world and 1 in 10,000 people in the European Union. Three main forms have been described: thalassemia major, thalassemia intermedia and thalassemia minor. Individuals with thalassemia major usually present within the first two years of life with severe anemia, requiring regular red blood cell (RBC transfusions. Findings in untreated or poorly transfused individuals with thalassemia major, as seen in some developing countries, are growth retardation, pallor, jaundice, poor musculature, hepatosplenomegaly, leg ulcers, development of masses from extramedullary hematopoiesis, and skeletal changes that result from expansion of the bone marrow. Regular transfusion therapy leads to iron overload-related complications including endocrine complication (growth retardation, failure of sexual maturation, diabetes mellitus, and insufficiency of the parathyroid, thyroid, pituitary, and less commonly, adrenal glands, dilated myocardiopathy, liver fibrosis and cirrhosis. Patients with thalassemia intermedia present later in life with moderate anemia and do not require regular transfusions. Main clinical features in these patients are hypertrophy of erythroid marrow with medullary and extramedullary hematopoiesis and its complications (osteoporosis, masses of erythropoietic tissue that primarily affect the spleen, liver, lymph nodes, chest and spine, and bone deformities and typical facial changes, gallstones, painful leg ulcers and increased predisposition to thrombosis. Thalassemia minor is clinically asymptomatic but some subjects may have moderate anemia. Beta-thalassemias are caused by point mutations or, more rarely

  14. Beta and muon decays

    International Nuclear Information System (INIS)

    These notes represent a series of lectures delivered by the authors in the Junta de Energia Nuclear, during the Spring term of 1965. They were devoted to graduate students interested in the Theory of Elementary Particles. Special emphasis was focussed into the computational problems. Chapter I is a review of basic principles (Dirac equation, transition probabilities, final state interactions.) which will be needed later. In Chapter II the four-fermion punctual Interaction is discussed, Chapter III is devoted to the study of beta-decay; the main emphasis is given to the deduction of the formulae corresponding to electron-antineutrino correlation, electron energy spectrum, lifetimes, asymmetry of electrons emitted from polarized nuclei, electron and neutrino polarization and time reversal invariance in beta decay. In Chapter IV we deal with the decay of polarized muons with radiative corrections. Chapter V is devoted to an introduction to C.V.C. theory. (Author)

  15. Integration of BETA with Eclipse

    DEFF Research Database (Denmark)

    Andersen, Peter; Madsen, Ole Lehrmann; Enevoldsen, Mads Brøgger

    2004-01-01

    This paper presents language interoperability issues appearing in order to implement support for the BETA language in the Java-based Eclipse integrated development environment. One of the challenges is to implement plug-ins in BETA and be able to load them in Eclipse. In order to do this, some form...... of language interoperability between Java and BETA is required. The first approach is to use the Java Native Interface and use C to bridge between Java and BETA. This results in a workable, but complicated solution. The second approach is to let the BETA compiler generate Java class files. With this...... approach it is possible to implement plug-ins in BETA and even inherit from Java classes. In the paper the two approaches are described together with part of the mapping from BETA to Java class files. http://www.sciencedirect.com/science/journal/15710661...

  16. COM Support in BETA

    DEFF Research Database (Denmark)

    Madsen, Ole Lehrmann

    1999-01-01

    Component technologies based on binary units of independent production are some of the most important contributions to software architecture and reuse during recent years. Especially the COM technologies and the CORBA standard from the Object Management Group have contributed new and interesting ...... principles for software architecture, and proven to be useful in parctice. In this paper ongoing work with component support in the BETA language is described....

  17. Beta decay for pedestrians

    CERN Document Server

    Lipkin, Harry Jeannot

    1962-01-01

    The ""pedestrian approach"" was developed to describe some essentially simple experimental results and their theoretical implications in plain language. In this graduate-level text, Harry J. Lipkin presents simply, but without oversimplification, the aspects of beta decay that can be understood without reference to the formal theory; that is, the reactions that follow directly from conservation laws and elementary quantum mechanics.The pedestrian treatment is neither a substitute for a complete treatment nor a watered-down version.

  18. LHCb: $2\\beta_s$ measurement at LHCb

    CERN Multimedia

    Conti, G

    2009-01-01

    A measurement of $2\\beta_s$, the phase of the $B_s-\\bar{B_s}$ oscillation amplitude with respect to that of the ${\\rm b} \\rightarrow {\\rm c^{+}}{\\rm W^{-}}$ tree decay amplitude, is one of the key goals of the LHCb experiment with first data. In the Standard Model (SM), $2\\beta_s$ is predicted to be $0.0360^{+0.0020}_{-0.0016} \\rm rad$. The current constraints from the Tevatron are: $2\\beta_{s}\\in[0.32 ; 2.82]$ at 68$\\%$CL from the CDF experiment and $2\\beta_{s}=0.57^{+0.24}_{-0.30}$ from the D$\\oslash$ experiment. Although the statistical uncertainties are large, these results hint at the possible contribution of New Physics in the $B_s-\\bar{B_s}$ box diagram. After one year of data taking at LHCb at an average luminosity of $\\mathcal{L}\\sim2\\cdot10^{32}\\rm cm^{-2} \\rm s^{-1}$ (integrated luminosity $\\mathcal{L}_{\\rm int}\\sim 2 \\rm fb^{-1}$), the expected statistical uncertainty on the measurement is $\\sigma(2\\beta_s)\\simeq 0.03$. This uncertainty is similar to the $2\\beta_s$ value predicted by the SM.

  19. Generation of Transplantable Beta Cells for Patient-Specific Cell Therapy

    Directory of Open Access Journals (Sweden)

    Xiaojie Wang

    2012-01-01

    Full Text Available Islet cell transplantation offers a potential cure for type 1 diabetes, but it is challenged by insufficient donor tissue and side effects of current immunosuppressive drugs. Therefore, alternative sources of insulin-producing cells and isletfriendly immunosuppression are required to increase the efficiency and safety of this procedure. Beta cells can be transdifferentiated from precursors or another heterologous (non-beta-cell source. Recent advances in beta cell regeneration from somatic cells such as fibroblasts could circumvent the usage of immunosuppressive drugs. Therefore, generation of patient-specific beta cells provides the potential of an evolutionary treatment for patients with diabetes.

  20. Xeroradiography in. beta. -thalassaemia

    Energy Technology Data Exchange (ETDEWEB)

    Scutellari, P.N.; Orzincolo, C.; Tamarozzi, R.

    1985-01-01

    Xeroradiographic investigations of the skull, hand, and elbow were performed on 27 patients with homozygous ..beta..-thalassaemia. The results were compared with plain radiographic examinations. Xeroradiography, because of its technical properties (i.e. edge contrast enhancement and wide latitude), was shown to demonstrate cortical thinning of long bones, swelling of the diploic space in the skull, and reticulated patterns in the elbow better than standard radiography. Moreover, the use of 'positive' mode imaging was shown to have advantages in the study of the skull and extremities.

  1. Realized Beta GARCH

    DEFF Research Database (Denmark)

    Hansen, Peter Reinhard; Lunde, Asger; Voev, Valeri Radkov

    2014-01-01

    particularly useful for modeling financial returns during periods of rapid changes in the underlying covariance structure. When applied to market returns in conjunction with returns on an individual asset, the model yields a dynamic model specification of the conditional regression coefficient that is known as...... conditional beta series during the financial crises.......We introduce a multivariate generalized autoregressive conditional heteroskedasticity (GARCH) model that incorporates realized measures of variances and covariances. Realized measures extract information about the current levels of volatilities and correlations from high-frequency data, which is...

  2. Double beta decay: present status

    OpenAIRE

    Barabash, A. S.

    2008-01-01

    The present status of double beta decay experiments (including the search for $2\\beta^{+}$, EC$\\beta^{+}$ and ECEC processes) are reviewed. The results of the most sensitive experiments are discussed. Average and recommended half-life values for two-neutrino double beta decay are presented. Conservative upper limits on effective Majorana neutrino mass and the coupling constant of the Majoron to the neutrino are established as $ < 0.75$ eV and $ < 1.9 \\cdot 10^{-4}$, respectively. Proposals fo...

  3. Simultaneous beta and gamma spectroscopy

    Science.gov (United States)

    Farsoni, Abdollah T.; Hamby, David M.

    2010-03-23

    A phoswich radiation detector for simultaneous spectroscopy of beta rays and gamma rays includes three scintillators with different decay time characteristics. Two of the three scintillators are used for beta detection and the third scintillator is used for gamma detection. A pulse induced by an interaction of radiation with the detector is digitally analyzed to classify the type of event as beta, gamma, or unknown. A pulse is classified as a beta event if the pulse originated from just the first scintillator alone or from just the first and the second scintillator. A pulse from just the third scintillator is recorded as gamma event. Other pulses are rejected as unknown events.

  4. Neutron bound {beta}- decay- BOB

    Energy Technology Data Exchange (ETDEWEB)

    Gabriel, M.; Berger, M.; Emmerich, R.; Faestermann, T.; Gutsmiedl, E.; Hartmann, F.J.; Paul, S.; Ruschel, S.; Schoen, J.; Schott, W.; Schubert, U.; Trautner, A. [Physik-Department, TUM, 85748 Garching (Germany); Engels, R. [Institut fuer Kernphysik, Forschungszentrum Juelich, 52425 Juelich (Germany); Fierlinger, P. [Excellence Cluster Universe, TUM, 85748 Garching (Germany); Hertenberger, R. [Sektion Physik, LMU, 85748 Garching (Germany); Roehrmoser, R. [FRM2, TUM, 85748 Garching (Germany); Udem, T. [Max-Planck-Institut fuer Quantenphysik, 85748 Garching (Germany)

    2011-07-01

    The bound neutron {beta}-decay(BOB) into a hydrogen atom and an electron antineutrino is investigated.The hyper-fine-state population of the monoenergetic hydrogen atoms (326.3 eV) yields the neutrino left-handed-ness or a possible right-handed admixture and possible small scalar and tensor contributions to the weak force. Preexperiments to measure the BOB H(2s) atoms have been done or are being set up using ionizer and RF discharge proton sources, a Wien filter, Cs and Ar cells, a spin filter, electric counter and accelerating fields, a double focusing magnet and a solar blind PM for the Lyman-{alpha} photons. In a first experiment, the charge exchange of the H(2s) atoms into H{sup -}, offering a selective method to discriminate these states against background, is investigated. In a second step the number of background H(2s) resulting from protons interacting with the walls of the experimental setup are determined. For this a quenching E field and a solar blind PM are used.

  5. BETA SPECTRA. I. Negatrons spectra

    International Nuclear Information System (INIS)

    Using the Fermi theory of beta decay, the beta spectra for 62 negatrons emitters have been computed introducing a correction factor for unique forbidden transitions. These spectra are plotted vs. energy, once normal i sed, and tabulated with the related Fermi functions. The average and median energies are calculated. (Author)

  6. The best-beta CAPM

    NARCIS (Netherlands)

    L. Zou

    2006-01-01

    The issue of 'best-beta' arises as soon as potential errors in the Sharpe-Lintner-Black capital asset pricing model (CAPM) are acknowledged. By incorporating a target variable into the investor preferences, this study derives a best-beta CAPM (BCAPM) that maintains the CAPM's theoretical appeal and

  7. RAVEN Beta Release

    Energy Technology Data Exchange (ETDEWEB)

    Rabiti, Cristian [Idaho National Lab. (INL), Idaho Falls, ID (United States); Alfonsi, Andrea [Idaho National Lab. (INL), Idaho Falls, ID (United States); Cogliati, Joshua Joseph [Idaho National Lab. (INL), Idaho Falls, ID (United States); Mandelli, Diego [Idaho National Lab. (INL), Idaho Falls, ID (United States); Kinoshita, Robert Arthur [Idaho National Lab. (INL), Idaho Falls, ID (United States); Wang, Congjian [Idaho National Lab. (INL), Idaho Falls, ID (United States); Maljovec, Daniel Patrick [Idaho National Lab. (INL), Idaho Falls, ID (United States); Talbot, Paul William [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-02-01

    This documents the release of the Risk Analysis Virtual Environment (RAVEN) code. A description of the RAVEN code is provided, and discussion of the release process for the M2LW-16IN0704045 milestone. The RAVEN code is a generic software framework to perform parametric and probabilistic analysis based on the response of complex system codes. RAVEN is capable of investigating the system response as well as the input space using Monte Carlo, Grid, or Latin Hyper Cube sampling schemes, but its strength is focused toward system feature discovery, such as limit surfaces, separating regions of the input space leading to system failure, using dynamic supervised learning techniques. RAVEN has now increased in maturity enough for the Beta 1.0 release.

  8. RAVEN Beta Release

    International Nuclear Information System (INIS)

    This documents the release of the Risk Analysis Virtual Environment (RAVEN) code. A description of the RAVEN code is provided, and discussion of the release process for the M2LW-16IN0704045 milestone. The RAVEN code is a generic software framework to perform parametric and probabilistic analysis based on the response of complex system codes. RAVEN is capable of investigating the system response as well as the input space using Monte Carlo, Grid, or Latin Hyper Cube sampling schemes, but its strength is focused toward system feature discovery, such as limit surfaces, separating regions of the input space leading to system failure, using dynamic supervised learning techniques. RAVEN has now increased in maturity enough for the Beta 1.0 release.

  9. Beta Beams Implementation at CERN

    CERN Document Server

    Hansen, Christian

    2011-01-01

    Beta Beam,the concept of generating a pure and intense (anti) neutrino beam by letting accelerated radioactive ions beta decay in a storage ring, called Decay Ring (DR), is the base of one of the proposed next generation neutrino oscillation facilities, necessary for a complete study of the neutrino oscillation parameter space. Sensitivities of the unknown neutrino oscillation parameters depend on the Decay Ring's ion intensity and of it's duty factor (the filled ratio of the ring). Therefore efficient ion production, stripping, bunching, acceleration and storing are crucial sub-projects under study and development within the Beta Beam collaboration. Specifically the feasibility of these tasks as parts of a Beta Beam implementation at CERN will be discussed in this report. The positive impact of the large {\\theta}13 indications from T2K on the Beta Beam performance will also be discussed.

  10. Design and operation of dust measuring instrumentation based on the beta-radiation method

    International Nuclear Information System (INIS)

    The theory, instrument design aspects and applications of beta-radiation attenuation for the measurement of mass concentration of airborne particulates are reviewed. Applicable methods of particle collection, beta sensing configurations, source and detector design criteria, and electronic signal processing are treated. Advantages, limitations, and error sources of beta-attenuation instrumentation are analysed. Applications to industrial dust measurements, source testing, ambient monitoring, and particle size analysis are the major areas of practical utilization of this technique, and its inherent capability for automated and unattended operation provides compatibility with process control surveillance and alarm, telemetry, and incorporation into pollution monitoring network sensing stations. (orig.)

  11. Simulation in double-beta decay experiments

    International Nuclear Information System (INIS)

    A detailed understanding of background radiation sources is a key to interpretation and enhanced sensitivity of double-beta decay experiments. Improvement of several techniques will be discussed. An implementation of the EGS4 code was developed to improve the accuracy of detector simulations, in particular for a 100Mo double-beta decay experiment. The efficiency modification due to the angular dependence of the 539 keV - 590 keV gamma-ray coincidence was successfully determined. The success of the 100Mo effort led to the modeling of uranium-thorium backgrounds found in an electroformed copper shield built for a 76Ge experiment. The large copper mass increased our sensitivity to contaminants present in copper produced this way, and led to changes in our cryostat electroforming technique. The original goal was the determination of the 210Pb content of the 450 year old lead shield previously used in 71Ge two-neutrino double-beta decay measurements. The results pertaining to low background materials and fabrication techniques will also be discussed

  12. A mini X-ray generator as an alternative to a 90Sr/90Y beta source in luminescence dating

    DEFF Research Database (Denmark)

    Andersen, C.E.; Bøtter-Jensen, L.; Murray, A.S.

    2003-01-01

    more practical. Furthermore, X-ray generators are more suited for field work and work in countries where regulations restrict the use of radioactive sources. The system tested here (a 50 kV I mA Varian VF-50J tube with tungsten target and a matched Spellman high-voltage power supply) was found to...

  13. Methodology to determine the efficiency of a beta emitter gases monitor; Metodologia para determinacao da eficiencia de um monitor de gases emissores de particulas beta

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, Marcos Rodrigues de

    1995-07-01

    This work presents a methodology developed to determinate the efficiency of air monitors used to measure the concentration of beta emitters noble gases in nuclear power stations. Efficiency values, obtained by means of theoretical computation are compared with experimental values. The experimental part of the work was performed using three different point beta source, to simulate small amounts of gas uniformly distributed in small volume. The comparison shows that theoretical an experimental values agree within 4,2 % for {sup 90}Sr + {sup 90}Y, {sup 204}Tl and {sup 45}Ca beta sources. (author)

  14. Intuitionistic Fuzzy Generalized Beta Closed Mappings

    OpenAIRE

    D. Jayanthi

    2014-01-01

    In this paper we introduce intuitionistic fuzzy generalized beta closed mappings and intuitionistic fuzzy generalized beta open mappings. We investigate some of their properties. We also introduce intuitionistic fuzzy M-generalized beta closed mappings as well as intuitionistic fuzzy M-generalized beta open mappings. We provide the relation between intuitionistic fuzzy M-generalized beta closed mappings and intuitionistic fuzzy generalized beta closed mappings.

  15. Derivatives of the Incomplete Beta Function

    Directory of Open Access Journals (Sweden)

    Robert J. Boik

    1998-03-01

    Full Text Available The incomplete beta function is defined as where Beta(p, q is the beta function. Dutka (1981 gave a history of the development and numerical evaluation of this function. In this article, an algorithm for computing first and second derivatives of Ix,p,q with respect to p and q is described. The algorithm is useful, for example, when fitting parameters to a censored beta, truncated beta, or a truncated beta-binomial model.

  16. Derivatives of the Incomplete Beta Function

    OpenAIRE

    Robison-Cox, James F.; Robert J. Boik

    1998-01-01

    The incomplete beta function is defined as where Beta(p, q) is the beta function. Dutka (1981) gave a history of the development and numerical evaluation of this function. In this article, an algorithm for computing first and second derivatives of Ix,p,q with respect to p and q is described. The algorithm is useful, for example, when fitting parameters to a censored beta, truncated beta, or a truncated beta-binomial model.

  17. Search for $\\beta^+$EC and ECEC processes in $^{74}$Se

    CERN Document Server

    Barabash, A S; Nachab, A; Umatov, V; Hubert, Ph.

    2006-01-01

    For the first time, limits on double-beta processes in $^{74}$Se have been obtained using a 400 cm$^3$ HPGe detector and an external source consisting of natural selenium powder. At a confidence level of 90%, they are $1.9\\times 10^{18}$ y for the $\\beta^+$EC$(0\

  18. New limits on the $\\beta^{+}$EC and ECEC processes in $^{120}$Te

    CERN Document Server

    Barabash, A S; Hubert, P; Umatov, V; Hubert, Ph

    2007-01-01

    New limits on the double beta processes for $^{120}$Te have been obtained using a 400 cm$^3$ HPGe detector and a source consisting of natural Te0$_2$ powder. At a confidence level of 90% the limits are $0.19\\times 10^{18}$ y for the $\\beta^+$EC$(0\

  19. High Temperature Stability of Potassium Beta Alumina

    Science.gov (United States)

    Williams, R. M.; Kisor, A.; Ryan, M. A.

    1996-01-01

    None. From Objectives section: Evaluate the stability of potassium beta alumina under potassium AMTEC operating conditions. Evaluate the stability regime in which potassium beta alumina can be fabricated.

  20. Beta decay measurements with ultracold neutrons: a review of recent measurements and the research program at Los Alamos National Laboratory

    International Nuclear Information System (INIS)

    We present a review of the motivation and results of recent experiments which utilize ultracold neutrons for measurements of neutron beta decay. Because these experiments hinge critically on the available ultracold neutron source technology, we also review the status of ultracold neutron source development, emphasizing the Los Alamos ultracold neutron facility and the ongoing beta decay research program sited there. (paper)

  1. Exposure of bremsstrahlung from beta-emitting therapeutic radionuclides

    Energy Technology Data Exchange (ETDEWEB)

    Manjunatha, H.C. [Department of Physics, Bangalore University, Bangalore-560056, Karnataka (India)], E-mail: manjunathhc@rediffmail.com; Rudraswamy, B. [Department of Physics, Bangalore University, Bangalore-560056, Karnataka (India)

    2009-02-15

    There has been an increased interest in beta therapeutic nuclear medicine, which emits relatively high-energy (>1 MeV) {beta}-rays and the production in vivo of Bremsstrahlung sufficient for external imaging, the produced Bremsstrahlung radiation hazard warrants evaluation. The Bremsstrahlung dose from patient administered {beta}-ray emitted radionuclide has been calculated by extending the national council on Radiation Protection and measurement model of a point source in air to account for biologic elimination of activity. We have estimated the probability of bremsstrahlung production, specific Bremsstrahlung constant (defined by Zanzonico et al.) and activity (A{sub release}) in bone cortical, bone compact, different regions of tooth enamel (enamel dentin junction (EDJ), enamel middle surface, enamel inner surface), different regions of dentin (outer surface, middle surface, enamel dentin junction (EDJ)), soft tissue, lungs and skeleton for different therapeutic beta-emitting radionuclide. In the present calculations we have used modified atomic number (Z{sub mod}) defined for bremsstrahlung process. Proper localization and quantification of incorporated beta emitters in bone and tooth are possible, because Bremsstrahlung production is greater in bone and tooth than soft tissue due to their high modified atomic number (Z{sub mod}). Radionuclide therapy with pure {beta}-ray emitters emitted in bone, tooth, soft tissue, lungs and skeleton does not require medical confinement of patients for radiation protection.

  2. History, biological effects, and dosimetry of beta radiation

    International Nuclear Information System (INIS)

    There has been a renewed interest in the dosimetry of beta radiation, particularly in the nuclear power industry. This interest is fueled by the current regulatory concern over exposure to hot particles. Hot particles are small, usually microscopic particles of fuel material or activated products produced as a result of neutron activation in a nuclear reactor. In addition, these particles are characterized as having very high specific activity and being composed primarily of beta-emitting radionuclides. Of primary interest in the dosimetry of hot particles is the absorbed dose and/or dose equivalent to the basal layer of the skin. Current federal regulations, as well as international and national radiation protection standards, do not address adequately the exposure of small areas of the skin from a single point source. In this paper, the history of beta dosimetry is reviewed with an emphasis on early beta-radiation exposures, such as those associated with fallout from nuclear weapons. Beta burns due to the black rain associated with the Japanese bombings and fallout studies at the Nevada test site and in the Pacific testing area provided much of the earliest data. Many survivors of the Japanese bombings were exposed to high-intensity beta radiation when they were caught in a rainout of material that had been sucked up into the fireball of the weapon

  3. A semiconductor beta ray spectrometer

    International Nuclear Information System (INIS)

    Measurement of energy spectra of beta particles emitted from nuclei in beta-decay processes provides information concerning the mass difference of these nuclei between initial and final state. Moreover, experimental beta spectra yield information on the feeding of the levels in the daughter nucleus. Such data are valuable in the construction and checking of the level schemes. This thesis describes the design, construction, testing and usage of a detector for the accurate measurement of the mentioned spectra. In ch. 2 the design and construction of the beta spectrometer, which uses a hyper-pure germanium crystal for energy determination, is described. A simple wire chamber is used to discriminate beta particles from gamma radiation. Disadvantages arise from the large amounts of scattered beta particles deforming the continua. A method is described to minimize the scattering. In ch. 3 some theoretical aspects of data analysis are described and the results of Monte-Carlo simulations of the summation of annihilation radiation are compared with experiments. Ch. 4 comprises the results of the measurements of the beta decay energies of 103-108In. 87 refs.; 34 figs.; 7 tabs

  4. Structural gene for beta-nerve growth factor not defective in familial dysautonomia.

    OpenAIRE

    Breakefield, X O; Orloff, G; Castiglione, C; Coussens, L.; Axelrod, F. B.; Ullrich, A

    1984-01-01

    The developmental loss of neurons in sympathetic, sensory, and some parasympathetic ganglia in familial dysautonomia suggests an inherited defect in the action of beta-nerve growth factor (beta-NGF). The role of this growth factor in dysautonomia has been difficult to resolve as there is no known source of authentic human beta-NGF. The availability of a cloned DNA probe for the human beta-NGF gene has allowed identification of some copies of the gene (alleles) in six affected families. Allele...

  5. Absorption of Beta Particles in Different Materials: An Undergraduate Experiment

    Science.gov (United States)

    La Rocca, Paola; Riggi, Francesco

    2009-01-01

    The absorption of beta rays from a radioactive source in different materials was investigated by the use of a simple setup based on a Geiger counter and a set of absorber sheets. The number of electrons traversing the material was measured as a function of its thickness. Detailed GEANT simulations were carried out to reproduce the obtained…

  6. Effect of beta blockade and beta stimulation on stage fright.

    Science.gov (United States)

    Brantigan, C O; Brantigan, T A; Joseph, N

    1982-01-01

    Stage fright, physiologically the "fight or flight" reaction, is a disabling condition to the professional musician. Because it is mediated by the sympathetic nervous system, we have investigated the effects of beta blockade on musical performance with propranolol in a double blind fashion and the effects of beta stimulation using terbutaline. Stage fright symptoms were evaluated in two trials, which included a total of 29 subjects, by questionnaire and by the State Trai Anxiety Inventory. Quality of musical performance was evaluated by experienced music critics. Beta blockade eliminates the physical impediments to performance caused by stage fright and even eliminates the dry mouth so frequently encountered. The quality of musical performance as judged by experienced music critics is significantly improved. This effect is achieved without tranquilization. Beta stimulating drugs increase stage fright problems, and should be used in performing musicians only after consideration of the detrimental effects which they may have on musical performance. PMID:6120650

  7. Beta decay of 31Ar

    International Nuclear Information System (INIS)

    A complete study of 31Ar beta decay has been made by high-resolution charged-particle and gamma-ray spectroscopy. Beta-delayed radiation was detected by an array of three charged-particle detectors and a large-volume germanium detector. Fifteen new energy levels were discovered in 31Cl. The beta-strength distribution, measured to 14.5 MeV, is compared with a shell-model calculation in the full sd space. The quenching of the Gamow-Teller strength and the isospin impurity of the IAS in 31Cl are discussed. (orig.)

  8. The Age of Beta Pic

    OpenAIRE

    Navascues, D. Barrado y; Stauffer, J. R.; Song, I.; Caillault, J-P.

    1999-01-01

    We have reanalyzed data for the proposed moving group associated with beta Pic in order to determine if the group (or part of it) is real, and, if so, to derive an improved age estimate for beta Pic. By using new, more accurate proper motions from PPM and Hipparcos and a few new radial velocities, we conclude that on kinematic grounds, two M dwarfs have space motions that coincide with that of beta Pic to within 1 km/s with small error bars. Based on a CM diagram derived from accurate photome...

  9. Smart Beta or Smart Alpha

    DEFF Research Database (Denmark)

    Winther, Kenneth Lillelund; Steenstrup, Søren Resen

    2016-01-01

    that smart beta investing probably will do better than passive market capitalization investing over time, we believe many are coming to a conclusion too quickly regarding active managers. Institutional investors are able to guide managers through benchmarks and risk frameworks toward the same well...... only superior to the common capitalization weighted index but also to their smart beta benchmark, even after cost for value, size, and low volatility funds. We encourage investors to increase the use of smart beta as benchmarks while still obtaining extra performance through active management—a concept...

  10. Experiments on double beta decay

    Energy Technology Data Exchange (ETDEWEB)

    Busto, J. [Neuchatel Univ. (Switzerland). Inst. de Physique

    1996-11-01

    The Double Beta Decay, and especially ({beta}{beta}){sub 0{nu}} mode, is an excellent test of Standard Model as well as of neutrino physics. From experimental point of view, a very large number of different techniques are or have been used increasing the sensitivity of this experiments quite a lot (the factor of 10{sup 4} in the last 20 years). In future, in spite of several difficulties, the sensitivity would be increased further, keeping the interest of this very important process. (author) 4 figs., 5 tabs., 21 refs.

  11. Resistance training & beta-hydroxy-beta-methylbutyrate supplementation on hormones

    OpenAIRE

    Hamid Arazi; Hadi Rohani; Ahmad Ghiasi; Nasrin Abdi Keikanloo

    2015-01-01

    RESUMOIntroduction:In recent years, there was an increased interest on the effects of beta-hydroxy-beta-methylbutyrate (HMB) supplementation on skeletal muscle due to its anti-catabolic effects.Objectives:To investigate the effect of HMB supplementation on body composition, muscular strength and anabolic-catabolic hormones after resistance training.Methods:Twenty amateur male athletes were randomly assigned to supplement and control groups in a double-blind crossover design and participated i...

  12. BEGe detector response to alpha and beta-radiation near its p{sup +} electrode

    Energy Technology Data Exchange (ETDEWEB)

    Bode, Tobias; Agostini, Matteo; Barnabe-Heider, Marik; Budjas, Dusan; Schoenert, Stefan [Technische Universitaet Muenchen (Germany); Collaboration: GERDA-Collaboration

    2012-07-01

    In Phase II of the GERDA (Germanium Detector Array) experiment Broad Energy Germanium (BEGe) detectors will continue the search for the neutrinoless double beta decay (0{nu}{beta}{beta}) of {sup 76}Ge. The main feature of these detectors is their small p{sup +} electrode used for signal read-out. Due to the thin dead layer of the p{sup +} contact, surface events close to this electrode represent a potential background for the search of 0{nu}{beta}{beta}. A study was conducted to determine the response of the detector to alpha and beta-radiation using movable collimated sources within a custom-build cryostat. Preliminary results of this study and a possible method to discriminate these events will be presented.

  13. Peginterferon Beta-1a Injection

    Science.gov (United States)

    ... symptoms such as headaches, bone or muscle aches, fever, chills, and tiredness during your treatment with peginterferon beta- ... not go away: headache muscle or joint pain fever chills weakness Some side effects can be serious. If ...

  14. Beta-gamma discriminator circuit

    International Nuclear Information System (INIS)

    The major difficulty encountered in the determination of beta-ray dose in field conditions is generally the presence of a relatively high gamma-ray component. Conventional dosimetry instruments use a shield on the detector to estimate the gamma-ray component in comparison with the beta-ray component. More accurate dosimetry information can be obtained from the measured beta spectrum itself. At Los Alamos, a detector and discriminator circuit suitable for use in a portable spectrometer have been developed. This instrument will discriminate between gammas and betas in a mixed field. The portable package includes a 256-channel MCA which can be programmed to give a variety of outputs, including a spectral display, and may be programmed to read dose directly

  15. Apollo applications of beta fiber glass

    Science.gov (United States)

    Naimer, J.

    1971-01-01

    The physical characteristics of Beta fiber glass are discussed. The application of Beta fiber glass for fireproofing the interior of spacecraft compartments is described. Tests to determine the flammability of Beta fiber glass are presented. The application of Beta fiber glass for commercial purposes is examined.

  16. Synthesis of Beta Pyridyl Carbinol Tartrate

    Directory of Open Access Journals (Sweden)

    S. K. Shukla

    1968-04-01

    Full Text Available A process for the synthesis of Beta pyridine carboxylic acid ethy1 ester starting from quinoline has been developed. Beta-pyridine carboxylic acid ethy1 ester on reduction with lithium aluminium hydride gave Beta-pyridy1 carbinol which on treatment tartaric acid yielded Beta-pyridy1 carbinol tartrate, a vaso dilator known in trade as "Ronicoltartrate".

  17. Phoswich Detector for Simultaneous Measuring Alpha/beta Particles

    International Nuclear Information System (INIS)

    The new type phoswich detector consisting of the ZnS(Ag) and plastic scintillator for alpha/beta-ray simultaneous counting was developed for monitoring radiological contamination inside pipes. The detection performance was estimated using the PSD (pulse shape discrimination) method as a function of distance between the scintillator and radioactive source. The attenuation of particles traveling through a thin film for preventing the detector from being contaminated was experimentally estimated. It is concluded from our investigation that the phoswich detector developed can provide a sufficient alpha/beta-ray discrimination. The application of a thin film for preventing the detector from being contaminated was proven to be feasible.

  18. Formation and Degradation of Beta-casomorphins in Dairy Processing

    OpenAIRE

    Nguyen, Duc Doan; Johnson, Stuart Keith; Busetti, Francesco; Solah, Vicky Ann

    2015-01-01

    Milk proteins including casein are sources of peptides with bioactivity. One of these peptides is beta-casomorphin (BCM) which belongs to a group of opioid peptides formed from β-casein variants. Beta-casomorphin 7 (BCM7) has been demonstrated to be enzymatically released from the A1 or B β-casein variant. Epidemiological evidence suggests the peptide BCM 7 is a risk factor for development of human diseases, including increased risk of type 1 diabetes and cardiovascular diseases but this has ...

  19. Methodology to determine the efficiency of a beta emitter gases monitor

    International Nuclear Information System (INIS)

    This work presents a methodology developed to determinate the efficiency of air monitors used to measure the concentration of beta emitters noble gases in nuclear power stations. Efficiency values, obtained by means of theoretical computation are compared with experimental values. The experimental part of the work was performed using three different point beta source, to simulate small amounts of gas uniformly distributed in small volume. The comparison shows that theoretical an experimental values agree within 4,2 % for 90Sr + 90Y, 204Tl and 45Ca beta sources. (author)

  20. Vasodilatory mechanisms of beta receptor blockade.

    OpenAIRE

    Rath, Géraldine; Balligand, Jean-Luc; Dessy, Chantal

    2012-01-01

    Beta-blockers are widely prescribed for the treatment of a variety of cardiovascular pathologies. Compared to traditional beta-adrenergic antagonists, beta-blockers of the new generation exhibit ancillary properties such as vasodilation through different mechanisms. This translates into a more favorable hemodynamic profile. The relative affinities of beta-adrenoreceptor antagonists towards the three beta-adrenoreceptor isotypes matter for predicting their functional impact on vasomotor contro...

  1. Tables of double beta decay data

    Energy Technology Data Exchange (ETDEWEB)

    Tretyak, V.I. [AN Ukrainskoj SSR, Kiev (Ukraine)]|[Strasbourg-1 Univ., 67 (France). Centre de Recherches Nucleaires; Zdesenko, Y.G. [AN Ukrainskoj SSR, Kiev (Ukraine)

    1995-12-31

    A compilation of experimental data on double beta decay is presented. The tables contain the most stringent known experimental limits or positive results of 2{beta} transitions of 69 natural nuclides to ground and excited states of daughter nuclei for different channels (2{beta}{sup -}; 2{beta}{sup +}; {epsilon}{beta}{sup +}; 2{epsilon}) and modes (0{nu}; 2{nu}; 0{nu}M) of decay. (authors). 189 refs., 9 figs., 3 tabs.

  2. Beta-ray dose assessment from skin contamination using a point kernel method

    International Nuclear Information System (INIS)

    In this study, a point kernel method to calculate beta-ray dose rate from skin contamination was introduced. The beta-ray doses rates were computed by performing numerical integration of the radial dose distribution around an isotropic point source of monoenergetic electrons called as point kernel. In this study, in-house code, based on MATLAB version 7.0.4 was developed to perform a numerical integration. The code generated dose distributions for beta-ray emitters from interpolated point kernel, and beta-ray dose rates from skin contamination were calculated by numerical integration. Generated dose distributions for selected beta-ray emitters agreed with those calculated by Cross et al within 20%, except at a longer distance where there are differences up to more than 100%. For a point source, calculated beta-ray doses were agreed well with those derived from Monte Carlo simulation. For a disk source, the differences were up to 17% at a deep region. Point kernel method underestimated beta-ray doses than Monte Carlo simulation. The code will be improved to deal with a three-dimensional source, shielding by cover material, air gap and contribution of photon to skin dose. For the sake of user's convenience, the code will be equipped with graphic user interface. (author)

  3. Effects of beta/gamma radiation on nuclear waste glasses

    Energy Technology Data Exchange (ETDEWEB)

    Weber, W.J. [Pacific Northwest National Lab., Richland, WA (United States)

    1997-07-01

    A key challenge in the disposal of high-level nuclear waste (HLW) in glass waste forms is the development of models of long-term performance based on sound scientific understanding of relevant phenomena. Beta decay of fission products is one source of radiation that can impact the performance of HLW glasses through the interactions of the emitted {beta}-particles and g-rays with the atoms in the glass by ionization processes. Fused silica, alkali silicate glasses, alkali borosilicate glasses, and nuclear waste glasses are all susceptible to radiation effects from ionization. In simple glasses, defects (e.g., non-bridging oxygen and interstitial molecular oxygen) are observed experimentally. In more complex glasses, including nuclear waste glasses, similar defects are expected, and changes in microstructure, such as the formation of bubbles, have been reported. The current state of knowledge regarding the effects of {beta}/{gamma} radiation on the properties and microstructure of nuclear waste glasses are reviewed. (author)

  4. In-trap decay spectroscopy for {beta}{beta} decays

    Energy Technology Data Exchange (ETDEWEB)

    Brunner, Thomas

    2011-01-18

    The presented work describes the implementation of a new technique to measure electron-capture (EC) branching ratios (BRs) of intermediate nuclei in {beta}{beta} decays. This technique has been developed at TRIUMF in Vancouver, Canada. It facilitates one of TRIUMF's Ion Traps for Atomic and Nuclear science (TITAN), the Electron Beam Ion Trap (EBIT) that is used as a spectroscopy Penning trap. Radioactive ions, produced at the radioactive isotope facility ISAC, are injected and stored in the spectroscopy Penning trap while their decays are observed. A key feature of this technique is the use of a strong magnetic field, required for trapping. It radially confines electrons from {beta} decays along the trap axis while X-rays, following an EC, are emitted isotropically. This provides spatial separation of X-ray and {beta} detection with almost no {beta}-induced background at the X-ray detector, allowing weak EC branches to be measured. Furthermore, the combination of several traps allows one to isobarically clean the sample prior to the in-trap decay spectroscopy measurement. This technique has been developed to measure ECBRs of transition nuclei in {beta}{beta} decays. Detailed knowledge of these electron capture branches is crucial for a better understanding of the underlying nuclear physics in {beta}{beta} decays. These branches are typically of the order of 10{sup -5} and therefore difficult to measure. Conventional measurements suffer from isobaric contamination and a dominating {beta} background at theX-ray detector. Additionally, X-rays are attenuated by the material where the radioactive sample is implanted. To overcome these limitations, the technique of in-trap decay spectroscopy has been developed. In this work, the EBIT was connected to the TITAN beam line and has been commissioned. Using the developed beam diagnostics, ions were injected into the Penning trap and systematic studies on injection and storage optimization were performed. Furthermore, Ge

  5. Study of pulse shape discrimination for beta events on the n{sup +} contact with BEGe detectors

    Energy Technology Data Exchange (ETDEWEB)

    Lazzaro, Andrea [Physik-Department E15, Technische Universitaet Muenchen (Germany); UNIMIB, Milano (Italy); Budjas, Dusan; Agostini, Matteo; Schoenert, Stefan [Physik-Department E15, Technische Universitaet Muenchen (Germany)

    2012-07-01

    For the second phase of the GERDA experiment, bare BEGe detectors will be deployed in liquid argon. In the GERDA commissioning runs it was observed that the {sup 42}Ar progeny ({sup 42}K) can create background at Q{sub {beta}{beta}}, if the ions are attracted on the detector surface. Beta particles from {sup 42}K decays (Q{sub {beta}}{approx}3.5 MeV) can penetrate the thick Li layer of the detectors n{sup +} contact surface and generate signals also at Q{sub {beta}{beta}}. With BEGe detectors these events can be identified and discriminated via pulse shape analysis. In this talk we present a study of surface beta events discrimination, using measurements of Sr and Ru sources with detectors in vacuum cryostats and the derived expected background suppression factor for {sup 42}K in LAr.

  6. Cardiac glycoside-like structure and function of 5 beta,14 beta-pregnanes

    International Nuclear Information System (INIS)

    5 beta-Reduction and 14 beta-substitution convert the planar progesterone molecule to the cardiac glycoside configuration--A and D rings of the steroid moiety are bent toward the alpha-face relative to the B and C rings. Potency of the 5 beta,14 beta-derivative in a [3H]ouabain binding assay or its ability to inhibit the sodium pump in red blood cells is enhanced by 3 beta-hydroxylation, 20 beta-hydroxylation, and 3 beta-glycosidation. Synthesis of 14,20 beta-dihydroxy-3 beta-(beta-D-glucopyranosyloxy)- 5 beta,14 beta-pregnane from digitoxin is described. The glucoside is 1/20 as potent as ouabain and elicits prominent, sustained, positive inotropy in isolated cardiac muscle

  7. Measurement of dose speed absorbed in depth imparted by sources external secondary patterns of beta radiation. Part 1 Measurement of dose speed absorbed in the surface of soft fabric for isotopes of 90Sr/90Y, 147Pm and 204TI

    International Nuclear Information System (INIS)

    The dose speed was measured absorbed for depth zero, (superficial) in soft equivalent fabric, for the secondary patterns four sources of beta radiation, (Nr. 86): 90Sr/90Y, (1850 MBq and 74 MBq respectively); 147Pm, (518 MBq) and 204TI, (18.5 MBq). The measurement is carried out to different distances of source-detecting separation, (11.0, 30.0 and 50.0 cm for the source of 1850 MBq, 30.0 cm for that of 74 MBq; 11.00 cm for the source of 147Pmand to contact for all the sources); maintaining the radiation sheaf aligned the one axis of symmetry of the detector, (α 0 degrees). The detector employed was a extrapolation chambers of variable electrodes and electrode fixed collector, (30 mm of diameter). In accordance with the principle of Bragg-Gray the volume of the chambers is varied and they register the variations of the current of collected ionization, correcting until for a maximum of thirteen correction factors that take into account the deviation to the suppositions that it establishes this principle. The certain values of the speed of superficial absorbed dose are in the following intervals: 90Sr/90Y, (1850 MBq, 0.0, 11.0, 30.0 and 50.0 cm): 43.164 mGy S-t, 0.544 mGy s-1 ,0.075 mGy s-1 and 0.027 mGy s-1, respectively, with a Global Analysis of the order of 1.17%, 1.17%, 1.14% and 1.66%, K J; 90Sr / 90Y, (74 MBq, 0.0 and 30 cm): 1.536 mGy s-1 and 0.002 mGy s-1, with Global Analysis of 1.19.0% and 5.22%, (K = 1) respectively, for the 147Pm, (0.0 and 11.0 in the interval of: 0.36 μGy s-1 and 0.43 μGy s-1, with one Global Analysis of 1 .42% and 4.28%, (K = 1), respectively; and finally for the 204TI, (0.0 cm) in the interval of 0.10 μGy s-1 with a Global Analysis of 1.27%. He calculates of the Global Analysis one carries out of agreement with those recommendations of the BIPM. In all the cases of source-detecting arrangement with separations different from zero, models of simple lineal regression were used. However for the case of the determination of the speed

  8. Thermoluminescent dosimeter-direct reading dosimeter dose discrepancy: studies on the role of beta radiation fields

    International Nuclear Information System (INIS)

    Dosimetry studies pertaining to thermoluminescent dosimeter (TLD) and direct reading dosimeter (DRD) have been performed for photons, beta fields and mixed field of photons and beta particles. In lab conditions, for pure photon radiation fields, the doses estimated using DRD and TLD match within the acceptable limits whereas in the mixed fields of photons and high energy beta particles, it has been found that the DRD doses are always higher than the corresponding whole body doses estimated by the TLD. This is due to the fact that DRD responds to high energy beta particles and the typical response of the DRD to high energy beta particles is observed to be in the range of 15-30%. This may lead to TLD-DRD dose discrepancy at workplaces where the skin doses received by the radiation workers from high energy beta sources in a given monitoring period are significant. The paper also provides a comparison of three different TLD-DRD discrepancy identification criteria available in literature for exposure conditions with a significant dose due to beta radiations. In addition, estimate of threshold beta dose which may lead to discrepancy as per the criteria have been studied. The results reported in this paper would be helpful in understanding the discrepancy arising out of variable response of DRD to beta radiations and will be useful in resolving the discrepancy in such cases. (author)

  9. Pax4 Expression does not Transduce Pancreatic Alpha Cells to Beta Cells

    Directory of Open Access Journals (Sweden)

    Ling Chen

    2015-07-01

    Full Text Available Background/Aims: The lack of available beta cells greatly limits the use of beta cell transplantation as a therapy for diabetes. Thus, generation of beta cells from other sources is substantially required. Pax4 has been shown to induce reprograming of alpha cells into beta cells during embryogenesis. Nevertheless, whether expression of Pax4 in adult alpha cells could trigger this alpha-to-beta cell reprogramming is unknown. Methods: Here we generated an adeno-associated virus carrying Pax4 and GFP under a CMV promoter (AAV-Pax4. We used AAV-Pax4 to transduce a mouse alpha cell line in vitro, and to transduce primary alpha cells in diabetic mice. Reprogramming was examined by double immunostaining and by changes in beta cell number. The effects on blood glucose were evaluated by fasting blood glucose and glucose response. Results: In vitro, Pax4 overexpression neither induced insulin expression, nor suppressed glucagon expression in alpha cells. In vivo, Pax4 overexpression failed to increase beta cell number, and did not alter hyperglycemia and glucose response in diabetic mice. Conclusion: Pax4 expression is not sufficient to transduce pancreatic alpha cells into beta cells. Overexpression of Pax4 in alpha cells may not increase functional beta cell number in diabetic patients.

  10. 50 years forward: beta cells.

    Science.gov (United States)

    Halban, Philippe A

    2015-08-01

    Our understanding of beta cell development and function has increased substantially these past 50 years but much remains to be learned before this knowledge can be put to clinical use. A comprehensive business plan will be necessary to develop a detailed molecular and functional blueprint of the beta cell in health and disease based on an integrated approach involving all necessary research disciplines. This blueprint will provide a platform for the development of novel therapeutic strategies for the treatment of both major forms of diabetes, foremost among them beta cell replacement therapy. This is one of a series of commentaries under the banner '50 years forward', giving personal opinions on future perspectives in diabetes, to celebrate the 50th anniversary of Diabetologia (1965-2015). PMID:25957776

  11. Predicting Neutrinoless Double Beta Decay

    CERN Document Server

    Hirsch, M; Valle, J W F; Moral, A V; Ma, Ernest

    2005-01-01

    We give predictions for the neutrinoless double beta decay rate in a simple variant of the A_4 family symmetry model. We show that there is a lower bound for the neutrinoless double beta decay amplitude even in the case of normal hierarchical neutrino masses, corresponding to an effective mass parameter |m_{ee}| >= 0.17 \\sqrt{\\Delta m^2_{ATM}}. This result holds both for the CP conserving and CP violating cases. In the latter case we show explicitly that the lower bound on |m_{ee}| is sensitive to the value of the Majorana phase. We conclude therefore that in our scheme, neutrinoless double beta decay may be accessible to the next generation of high sensitivity experiments.

  12. Radioisotope Power Sources

    International Nuclear Information System (INIS)

    The radioisotope power programme of the US Atomic Energy Commission has brought forth a whole new technology of the use of radioisotopes as energy sources in electric power generators. Radioisotope power systems are particularly suited for remote applications where long-lived, compact, reliable power is needed. Able to perform satisfactorily under extreme environmental conditions of temperature, sunlight and electromagnetic radiations, these ''atomic batteries'' are attractive power sources for remote data collecting devices, monitoring systems, satellites and other space missions. Radioisotopes used as fuels generally are either alpha or beta emitters. Alpha emitters are the preferable fuels but are more expensive and less available than beta fuels and are generally reserved for space applications. Beta fuels separated from reactor fission wastes are being used exclusively in land and sea applications at the present. It can be expected, however, that beta emitters such as stiontium-90 eventually will be used in space. Development work is being carried out on generators which will use mixed fission products as fuel. This fuel will be less expensive than the pure radioisotopes since the costs of isotope separation and purification are eliminated. Prototype thermoelectric generators, fuelled with strontium-90 and caesium-137, are now in operation or being developed for use in weather stations, marine navigation aids and deep sea monitoring devices. A plutonium-238 thermoelectric generator is in orbit operating as electric power source in a US Navy TRANSIT satellite. Generators are under development for use on US National Aeronautics and Space Administration missions. The large quantities of radioactivity involved in radioisotope power sources require that special attention be given to safety aspects of the units. Rigid safety requirements have been established and extensive tests have been conducted to insure that these systems can be employed without creating undue

  13. Mechanism of inactivation of alanine racemase by beta, beta, beta-trifluoroalanine

    International Nuclear Information System (INIS)

    The alanine racemases are a group of PLP-dependent bacterial enzymes that catalyze the racemization of alanine, providing D-alanine for cell wall synthesis. Inactivation of the alanine racemases from the Gram-negative organism Salmonella typhimurium and Gram-positive organism Bacillus stearothermophilus with beta, beta, beta-trifluoroalanine has been studied. The inactivation occurs with the same rate constant as that for formation of a broad 460-490-nm chromophore. Loss of two fluoride ions per mole of inactivated enzyme and retention of [1-14C]trifluoroalanine label accompany inhibition, suggesting a monofluoro enzyme adduct. Partial denaturation (1 M guanidine) leads to rapid return of the initial 420-nm chromophore, followed by a slower (t1/2 approximately 30 min-1 h) loss of the fluoride ion and 14CO2 release. At this point, reduction by NaB3H4 and tryptic digestion yield a single radiolabeled peptide. Purification and sequencing of the peptide reveals that lysine-38 is covalently attached to the PLP cofactor. A mechanism for enzyme inactivation by trifluoroalanine is proposed and contrasted with earlier results on monohaloalanines, in which nucleophilic attack of released aminoacrylate on the PLP aldimine leads to enzyme inactivation. For trifluoroalanine inactivation, nucleophilic attack of lysine-38 on the electrophilic beta-difluoro-alpha, beta-unsaturated imine provides an alternative mode of inhibition for these enzymes

  14. An ISPA-camera for $\\beta$-radiography

    CERN Document Server

    Puertolas, D; Leutz, H; Gys, Thierry; D'Ambrosio, C

    1996-01-01

    We have developed a new type of beta-camera based on an Imaging Silicon Pixel Array (ISPA)-tube combined with planar plastic scintillators or with SiY2O5(Ce)-scintillating powder. The ISPA-tube consists of a photocathode viewed at 3 cm distance by a silicon anode divided into 1024 rectangular (75 microm x 500 microm) detector pixels, each bump-bonded to its equally-sized electronic pixel. Depending on the beta-detector thickness we achieved spatial resolutions (FWHM) between 105 microm (63Ni source and 30 microm thick plastic scintillator) and 240 microm (90Sr-90Y source and 120 microm thick plastic scintillator) by covering the detectors with brass templates. With their four 60 microm wide slits oriented parallel to the long pixel edges we simulated small sized beta-strips. The impact of detector thickness is explained by multiple scattering, angular aperture of the template slits and scintillating light distribution at the ISPA-photocathode. Beta detection sensitivities were measured with calibrated...

  15. Measurement of the 2{nu}{beta}{beta} decay of {sup 100}Mo to the excited 0{sub 1}{sup +} state in the NEMO3 experiment

    Energy Technology Data Exchange (ETDEWEB)

    Vala, L

    2003-09-01

    The NEMO3 detector was designed for the study of double beta decay and in particular to search for the neutrinoless double beta decay process (0{nu}{beta}{beta}). The intended sensitivity in terms of a half-life limit for the 0{nu}{beta}{beta} decay is of the order of 10{sup 25} y which corresponds to an effective neutrino mass m{sub {nu}} on the level of (0.3 - 0.1) eV. The 0{nu}{beta}{beta} process is today the most promising test of the Majorana nature of the neutrino. The detector was constructed in the Modane Underground Laboratory (LSM) in France by an international collaboration including France, Russia, the Czech Republic, the USA, the UK, Finland, and Japan. The experiment has been taking data since May 2002. The quantity of {sup 100}Mo in the detector (7 kg) allows an efficient measurement of the two-neutrino double beta decay (2{nu}{beta}{beta}) of {sup 100}Mo to the excited 0{sub 1}{sup +} state (eeN{gamma} channel). Monte-Carlo simulations of the effect and of all the relative sources of background have been produced in order to define a set of appropriate selection criteria. Both Monte-Carlo simulations and special runs with sources of {sup 208}Tl and {sup 214}Bi showed that the only significant background in the eeN{gamma} channel comes from radon that penetrated inside the wire chamber of NEMO3. The experimental data acquired from May 2002 to May 2003 have been analysed in order to determine the signal from the 2{nu}{beta}{beta} decay of {sup 100}Mo to the excited 0{sub 1}{sup +} state and the corresponding background level. The physical result, which was obtained at the level of four standard deviations, is given in the form of an interval of half-life values at 95% confidence level: [5.84*10{sup 20}, 2.26*10{sup 21}] y for method A and [5.83*10{sup 20}, 1.71*10{sup 21}] y for method B. (author)

  16. Proteins differentially expressed in human beta-cells-enriched pancreatic islet cultures and human insulinomas

    DEFF Research Database (Denmark)

    Terra, Letícia F; Teixeira, Priscila C; Wailemann, Rosangela A M;

    2013-01-01

    In view of the great demand for human beta-cells for physiological and medical studies, we generated cell lines derived from human insulinomas which secrete insulin, C-peptide and express neuroendocrine and islet markers. In this study, we set out to characterize their proteomes, comparing them to...... molecular snapshot of the orchestrated changes in expression of proteins involved in key processes which could be correlated with the altered phenotype of human beta-cells. Collectively our observations prompt research towards the establishment of bioengineered human beta-cells providing a new and needed...... source of cultured human beta-cells for beta-cell research, along with the development of new therapeutic strategies for detection, characterization and treatment of insulinomas....

  17. IFN-beta gene deletion leads to augmented and chronic demyelinating experimental autoimmune encephalomyelitis

    DEFF Research Database (Denmark)

    Teige, Ingrid; Treschow, Alexandra; Teige, Anna; Mattsson, Ragnar; Navikas, Vaidrius; Leanderson, Tomas; Holmdahl, Rikard; Issazadeh-Navikas, Shohreh

    2003-01-01

    Since the basic mechanisms behind the beneficial effects of IFN-beta in multiple sclerosis (MS) patients are still obscure, here we have investigated the effects of IFN-beta gene disruption on the commonly used animal model for MS, experimental autoimmune encephalomyelitis (EAE). We show that IFN...... proliferate or produce IFN-gamma in response to recall Ag. Consequently, we addressed the effect of IFN-beta on encephalitogenic T cell development and the disease initiation phase by passive transfer of autoreactive T cells from KO or wt littermates to both groups of mice. Interestingly, IFN-beta KO mice...... acquired a higher incidence and augmented EAE regardless of the source of T cells. This shows that the anti-inflammatory effect of endogenous IFN-beta is predominantly exerted on the effector phase of the disease. Histopathological investigations of CNS in the effector phase revealed an extensive microglia...

  18. Screening of beta-glucan contents in commercially cultivated and wild growing mushrooms.

    Science.gov (United States)

    Sari, Miriam; Prange, Alexander; Lelley, Jan I; Hambitzer, Reinhard

    2017-02-01

    Mushrooms have unique sensory properties and nutritional values as well as health benefits due to their bioactive compounds, especially beta-glucans. Well-known edible and medicinal mushroom species as well as uncommon or unknown species representing interesting sources of bioactive beta-glucans have been widely studied. Commercially cultivated and wild growing mushrooms were analysed for their beta-glucan contents. Enzymatic determinations of all glucans, alpha-glucans and beta-glucans in 39 mushrooms species were performed, leading to very remarkable results. Many wild growing species present high beta-glucan contents, especially Bracket fungi. The well-known cultivated species Agaricus bisporus, Lentinula edodes and Cantharellus cibarius as well as most screened wild growing species show higher glucan contents in their stipes than caps. PMID:27596390

  19. Constraining neutrinoless double beta decay

    International Nuclear Information System (INIS)

    A class of discrete flavor-symmetry-based models predicts constrained neutrino mass matrix schemes that lead to specific neutrino mass sum-rules (MSR). We show how these theories may constrain the absolute scale of neutrino mass, leading in most of the cases to a lower bound on the neutrinoless double beta decay effective amplitude.

  20. *608440 LACTAMASE, BETA; LACTB [OMIM

    Lifescience Database Archive (English)

    Full Text Available FIELD NO 608440 FIELD TI 608440 LACTAMASE, BETA; LACTB ;;MITOCHONDRIAL RIBOSOMAL PROTEIN L56; MR ... Chen et al. (2008) recorded weight, fat mass, and lean ... mass for Lpl heterozygous null mice, Lactb transge ... ifferent from those of controls, with the fat mass/lean ... mass ratio difference generally increasing over ti ...

  1. Monitor for alpha beta contamination of hands

    International Nuclear Information System (INIS)

    The following specifications of hands alpha beta contamination monitor are presented: the position of the hands, the detection and separation of alpha and beta, the information processing, the programming, the results presentation and general characteristics. (A.L.B.)

  2. How Do Beta Blocker Drugs Affect Exercise?

    Science.gov (United States)

    ... Stroke More How do beta blocker drugs affect exercise? Updated:Aug 5,2015 Beta blockers are a ... about them: Do they affect your ability to exercise? The answer can vary a great deal, depending ...

  3. Interferon Beta-1a Intramuscular Injection

    Science.gov (United States)

    Interferon beta-1a intramuscular injection is used to reduce the number of episodes of symptoms and slow ... and problems with vision, speech, and bladder control). Interferon beta-1a is in a class of medications ...

  4. Interferon Beta-1a Subcutaneous Injection

    Science.gov (United States)

    Interferon beta-1a subcutaneous injection is used to reduce episodes of symptoms and slow the development of ... and problems with vision, speech, and bladder control). Interferon beta-1a is in a class of medications ...

  5. On some corrections to beta spectra measured by toroidal inron-free beta spectrometer

    International Nuclear Information System (INIS)

    In the investigations of the features of neutron-deficient isotopes to study low-intensity branches of positron decay ST-2 the iron-free beta spectrometer with toroidal magnetic field (light intensity approximately 20%, resolution ability approximately 1%) is used. The influence of the factors distorting β-spectra in case of the ST-2 spectrometer has been studied. In using the sources without the carriers the source thickness at Esub(β) > 100 keV doesn't distort the spectrum. The investigation of the dependence of 22Na positron counting at different energies on theckness of the substrate made it possible to determine the paremeters of backscattering. It was shown that the backgroud of the spectrometer in positron measuring regime at energies Esub(β) > 100 keV didn't depend on the energy. The measurements at the energies higher than maximum positron energy give directly the background value. According to experimental distribution of the lines of conversion electrons the analytical kind of response function of the spectrometer has been obtained. Spectral distribution of monochromatic electrons consists of the peak, described by Gauss distribution, and exponential ''tail'' in the direction of small energies. The investigations showed that with the help of the ST-2 beta spectrometer the decay positron btanches with the intensity up to 0.01% per decay may be determined with the accuracy 2-3 keV. There is principal possibility to study form factors of β-spectra

  6. The beta subunit of casein kinase II

    DEFF Research Database (Denmark)

    Boldyreff, B; Piontek, K; Schmidt-Spaniol, I; Issinger, O G

    1991-01-01

    cDNAs encoding the beta subunit of pig and mouse CKII were isolated. The porcine cDNA was expressed as a fusion protein in Escherichia coli and used for the production of anti-CKII-beta subunit specific antibodies.......cDNAs encoding the beta subunit of pig and mouse CKII were isolated. The porcine cDNA was expressed as a fusion protein in Escherichia coli and used for the production of anti-CKII-beta subunit specific antibodies....

  7. Beta adrenergic receptors in pigmented ciliary processes.

    OpenAIRE

    Trope, G. E.; Clark, B.

    1982-01-01

    Beta adrenergic receptors from membrane fragments of pigmented sheep eyes were studied and characterised by ligand binding techniques after the removal of melanin. In a representative experiment the beta max (total number of beta receptors) was 394.9 fmol/mg protein. The receptor affinity (Ka) was 440 pM. The potency series of drugs to displace 125I-HYP from the receptors was timolol = (-) propranolol greater than (+) propranolol greater than salbutamol greater than practolol. beta 1 Recepto...

  8. Some methods for calibration and beta radiation dosimetry

    International Nuclear Information System (INIS)

    The calibration of beta radiation was studied from the point of view of primary and secondary standardization, using extrapolation chambers and examining several effects. The properties of a commercial ionization chamber were investigated, and the possibility of its use in calibration and dosimetry of 90Sr- 90Y beta radiation was demonstrated . A secondary standard calibration facility was developed and the results obtained with this facility were compared with those obtained from a primary system directly or indirectly. Nearly energy independent response was obtained in.the range 60 keV to 0,8 MeV with this secondary standard. Two solid state techniques namely thermoluminescence (TL) and thermally stimulated exoelectron emission (TSEE) were also used for beta dosimetry. Various characteristics like reproducibility, response with dose,energy dependence, etc. were studied for the materials: LiF, CaF2,Li2B4O7, Be O, CaSO4 and Al2O3. TL detectors of thickness 0,9 mm underestimate the dose 60 μm thick CaSO4:Tm embedded on a thin aluminium plate gave energy independent response behind skin layers of 7 mg/cm2. Mixed field of beta, X and gamma radiation was analysed using this detector. Quartz based Be O and graphite based alpha beta-Al2O3 were found to be good beta radiation detectors when the TSEE technique is used. Energy independent CaSO4:Tm TL dosimeters were used in international comparison for dose measurements and the results obtained were in agreement with the actual given doses within 10%. The TL detectors were also used for dose rate measurements from glazed painted tiles used in construction industry and a 85Kr source used in textile and metal industries. Results obtained in the later case were Q compared with those using the secondary standard facility. (author)

  9. Theory of high-beta tokamaks

    International Nuclear Information System (INIS)

    The theoretical researches on high beta tokamak are reviewed. The ballooning mode instability is thought to be the most serious problem for the high beta tokamaks, and the theoretical results on the ballooning mode instability are discussed in detail. The experimental results in high beta belt pinch devices are also discussed. (author)

  10. Interferon Beta-1a Intramuscular Injection

    Science.gov (United States)

    Interferon beta-1a intramuscular injection is used to reduce the number of episodes of symptoms and slow the development of disability in patients ... Interferon beta-1a intramuscular injection comes as a powder in vials to be mixed into a solution for injection. Interferon beta-1a intramuscular ...

  11. Beta measurements at Department of Energy facilities

    International Nuclear Information System (INIS)

    Pacific Northwest Laboratory performed a two-step process to characterize the current beta measurement practices at DOE facilities. PNL issued a survey questionnaire on beta measurement practices to DOE facilities and reported the results. PNL measured beta doses and spectra at seven selected DOE facilities and compared selected measurement techniques in the facility environment. This report documents the results of the radiation field measurements and the comparison of measurement techniques at the seven facilities. Data collected included beta dose and spectral measurements at seven DOE facilities that had high beta-to-gamma ratios (using a silicon surface barrier spectrometer, a plastic scintillator spectrometer, and a multielement beta dosimeter). Other dosimeters and survey meters representative of those used at DOE facilities or under development were also used for comparison. Field spectra were obtained under two distinct conditions. Silicon- and scintillation-based spectrometer systems were used under laboratory conditions where high beta-to-gamma dose ratios made the beta spectra easier to observe and analyze. In the second case, beta spectrometers were taken into actual production and maintenance areas of DOE facilities. Analyses of beta and gamma spectra showed that 234Th- /sup 234m/Pa, 231Th, 137Cs, and 90Sr/90Y were the major nuclides contributing to beta doses at the facilities visited. Beta doses from other fission products and 60Co were also measured, but the potential for exposure was less significant. 21 refs., 64 figs., 18 tabs

  12. High-precision thickness measurements using beta backscatter

    International Nuclear Information System (INIS)

    A two-axis, automated fixture for use with a high-intensity Pm-147 source and a photomultiplier-scintillation beta-backscatter probe for making thickness measurements has been designed and built. A custom interface was built to connect the system to a minicomputer, and software was written to position the tables, control the probe, and make the measurements. Measurements can be made in less time with much greater precision than by the method previously used

  13. Enzymology of the beta-ketoadipate pathway in Trichosporon cutaneum.

    OpenAIRE

    Powlowski, J B; Ingebrand, J; Dagley, S

    1985-01-01

    Cell extracts were prepared from Trichosporon cutaneum grown with phenol or p-cresol, and activities were assayed for enzymes catalyzing conversion of these two carbon sources into 3-ketoadipate (beta-ketoadipate) and 3-keto-4-methyladipate, respectively. When activities of each enzyme were expressed as a ratio, the rate for methyl-substituted substrate being divided by that for the unsubstituted substrate, it was apparent that p-cresol-grown cells elaborated pairs of enzymes for hydroxylatio...

  14. Remote Sensing of Alpha and Beta Sources - Modeling Summary

    International Nuclear Information System (INIS)

    Evaluating the potential for optical detection of the products of interactions of energetic electrons or other particles with the background atmosphere depends on predictions of change in atmospheric concentrations of species which would generate detectable spectral signals within the range of observation. The solar blind region of the spectrum, in the ultra violet, would be the logical band for outdoor detection (see Figure 1). The chemistry relevant to these processes is composed of ion-molecule reactions involving the initially created N2+ and O2+ ions, and their subsequent interactions with ambient trace atmospheric constituents. Effective modeling of the atmospheric chemical system acted upon by energetic particles requires knowledge of the dominant mechanism that exchange charge and associate it with atmospheric constituents, kinetic parameters of the individual processes (see e.g. Brasseur and Solomon, 1995), and a solver for the coupled differential equations that is accurate for the very stiff set of time constants involved. The LLNL box model, VOLVO, simulates the diel cycle of trace constituent photochemistry for any point on the globe over the wide range of time scales present using a stiff Gear-type ODE solver, i.e. LSODE. It has been applied to problems such as tropospheric and stratospheric nitrogen oxides, stratospheric ozone production and loss, and tropospheric hydrocarbon oxidation. For this study we have included the appropriate ion flux

  15. Estimate of beta and gamma contamination in vegetable and animal biologic samples using GM detectors

    International Nuclear Information System (INIS)

    The paper presents the use of a large area Geiger-Mueller Detector (GMD) with aluminium window of 50 mm thickness (3,4 mg/cm2) in a measuring chain in order to estimate the beta and gamma contamination of biologic samples. The technical data for GMD are: - window area for gamma radiation: 300 cm2; - grid transmission: 80%; - operating voltage: 1100 - 1300 V; - minimum detectable beta energy: 125 keV; - dead time: 250 ms; - background (shielded with 100 mm Pb + 1 mm Cu): 6 pulses/s; - service life: 5 x 108 counts. Using this GMD together with a set of large area beta standard sources and a set of point gamma sources we could estimate beta and gamma contamination in the energy range 125 keV - 2.5 MeV for biologic samples. (authors)

  16. The change of transforming growth factor {beta} 1 (TGF- {beta} 1) expression by melatonin in irradiated lung

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Seong Soon; Choi, Ihl Bohng [College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of)

    2005-09-15

    The changed expressions of TGF- {beta} 1, as a key cytokine in the fibrotic process, due to melatonin with potent antioxidative effects, were investigated in the irradiated lung using fibrosis-sensitive C57BL/6 mice. Female C57BL/6 mice were divided into control irradiation-only, and melatonin (300 mg/kg i.p. 1 hr before irradiation) pretreatment groups. The thoraces of the mice were irradiated with a single dose of 12 Gy. The mRNA expressions of TGF-{beta} 1 in the lung tissue 2 and 4 weeks after irradiation were quantified using semiquantitive RT-PCR, and the cellular origin and expression levels of TGF- {beta} 1 protein were identified using immunohistochemical staining. The relative mRNA expression levels in the irradiation-only and melatonin pretreatment group 2 and 4 weeks after irradiation were 1.92- and 1.80-fold ({rho} = 0.064) and 2.38- and 1.94-fold ({rho} = 0.004) increased, respectively compared to those in the control group. Increased expressions of TGF- {beta} 1 protein were prominently detected in regions of histopathological radiation injury, with alveolar macrophages and septal epithelial cells serving as important sources of TGF- {beta} 1 expression. At 2 and 4 weeks after irradiation, the expression levels of protein were 15.8% vs. 16.9% ({rho} = 0.565) and 36.1% vs. 25.7% ({rho} = 0.009), respectively. The mRNA and protein expressions of TGF- {beta} 1 in the lung tissue following thoracic irradiation with 12 Gy were significantly decreased by melatonin pretreatment at 4 weeks. These results indicate that melatonin may have a possible application as an antifibrotic agent in radiation-induced lung injury.

  17. Purification and characterisation of an extracellular fructan beta-fructosidase from a Lactobacillus pentosus strain isolated from fermented fish

    DEFF Research Database (Denmark)

    Paludan-Müller, Christine; Gram, Lone; Rattray, F.P.

    2002-01-01

    Lactobacillus pentosus B235, which was isolated as part of the dominant microflora from a garlic containing fermented fish product, was grown in a chemically defined medium With inulin as the sole carbohydrate source. An extracellular fructan beta- fructosidase was purified to homogeneity from the...... fructan), but also hydrolysed garlic extract, (a beta(2-->1)-linked fructan with beta(2-->6)-linked fructosyl sidechains), 1,1,1-kestose, 1,1-kestose, 1-kestose, inulin (beta(2-->1)-linked fructans) and Sucrose at 60, 45, 39, 12, 9 and 3%, respectively, of the activity observed for levan. Melezitose...

  18. Purification and characterisation of an extracellular fructan beta-fructosidase from a Lactobacillus pentosus strain isolated from fermented fish

    DEFF Research Database (Denmark)

    Paludan-Müller, Christine; Gram, Lone; Rattray, Fergal P

    2002-01-01

    Lactobacillus pentosus B235, which was isolated as part of the dominant microflora from a garlic containing fermented fish product, was grown in a chemically defined medium with inulin as the sole carbohydrate source. An extracellular fructan beta-fructosidase was purified to homogeneity from the...... fructan), but also hydrolysed garlic extract, (a beta(2-->1)-linked fructan with beta(2-->6)-linked fructosyl sidechains), 1,1,1-kestose, 1,1-kestose, 1-kestose, inulin (beta(2-->1)-linked fructans) and sucrose at 60, 45, 39, 12, 9 and 3%, respectively, of the activity observed for levan. Melezitose...

  19. Absolute measurement of {beta} activities and application to the determination of neutronic densities; Mesure absolue d'activites {beta} et application a la determination des densites neutronique

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, R. [Commissariat a l' Energie Atomique, Lab. du Fort de Chatillon, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1951-01-15

    M. Berthelot, to my entrance to the ''Commissariat a l 'Energie Atomique'', proposed me to study the absolute measurement of neutron densities. Very quickly the problem of the absolute activity of {beta} sources became the central object of this work. In a first part, we will develop the methods of absolute determination for {beta} activities. The use of a 4{pi} counter permits to get the absolute activity of all beta radioactive source, susceptible to be put as thin leaf and of period superior than some minutes. The method is independent of the spectra of the measured radioelement. we will describe in the second part some applications which use neutron densities measurement, neutron sources intensities and ratio of cross sections of capture of thermal neutrons. (M.B.) [French] M. Berthelot, a mon entree au ''Commissariat a l 'Energie Atomique'', m'a propose d'etudier la mesure absolue des densites neutroniques. Tres rapidement le probleme de l'activite absolue des sources beta est devenu l'objet central de ce travail. Dans une premiere partie, on abordera les methodes de determination absolue des activites beta. L'utilisation d'un compteur 4{pi} permet d 'obtenir l'activite absolue de toute source radioactive beta, susceptible d'etre mise sous forme de feuille mince et de periode superieure a quelques minutes. La methode est independante du spectre du radioelement mesure. On decrira dans la seconde partie quelques applications a des mesures de densites neutroniques, d'intensites de sources de neutrons et de rapport de sections efficaces de capture de neutrons thermiques. (M.B.)

  20. Measurement of the beta asymmetry in neutron beta decay

    International Nuclear Information System (INIS)

    Neutron beta decay is the simplest semi-leptonic weak decay and described accurately by the standard model using the first CKM-matrix element and the ratio of vector and axial vector couplings, λ. With more than a dozen observables it is a sensitive probe for investigating the nature of weak interaction and to search for physics beyond the standard model. In the past, measuring the beta asymmetry A in polarized neutron decay has been the most precise way of determining λ and nowadays it allows - together with other observables - to derive limits on non-standard model interactions, such as scalar and tensor couplings. The neutron decay spectrometer Perkeo III was installed at the PF1B cold neutron beam site at the Institut Laue-Langevin to measure the beta asymmetry. By using a pulsed beam combined with an improved detector design a significant reduction of several systematic uncertainties has been achieved compared to the predecessor, Perkeo II. In this talk recent results of the measurements with Perkeo III will be presented. In particular, we show the energy distribution of the electrons together with the calibration tools for the detectors.

  1. Performance of a parallel plate ionization chamber in beta radiation dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Antonio, Patricia L.; Caldas, Linda V.E., E-mail: patrilan@ipen.b, E-mail: lcaldas@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    A homemade parallel plate ionization chamber with graphite collecting electrode, and developed for use in mammography beams, was tested in relation to its usefulness in beta radiation dosimetry at the Calibration Laboratory of IPEN. Characterization tests of this ionization chamber were performed, using the Sr-90 + Y-90, Kr-85 and Pm-147 sources of a beta secondary standard system. The results of saturation, leakage current, stabilization time, response stability, linearity, angular dependence, and calibration coefficients are within the recommended limits of international recommendations that indicate that this chamber may be used for beta radiation dosimetry. (author)

  2. Searches for heavy neutrinos from 35S, 14C, and 63Ni beta decay

    International Nuclear Information System (INIS)

    We have searched for the effect of a neutrino of mass 17 keV/c2 in the beta decay of 35S with an apparatus incorporating a high resolution solid state detector and a super conducting solenoid. The experimental mixing probability of the 17keV neutrino is consistent with zero. The experimental sensitivity is verified by measurements with a mixed source of 35S and 14C, which artificially produces a distortion in the beta spectrum similar to that expected from the massive neutrino. Recently, we have performed similar searches in the beta decay of 14C and 63Ni. Results of these new measurements will be presented

  3. Simulation of the dose rate per activity of beta-emitting radionuclides

    International Nuclear Information System (INIS)

    The dose rate per activity was simulated for 10 beta-emitting radionuclides and for different activity distributions (point source, areal sources and a semi-infinite volume source). The results are given for 7 different distances from the source (from 0.01 to 2 m) for both contributions: the beta- and electron-emission, and the X- and gamma-emission. Data are provided for both operational quantities and organ doses: Hp(0.07), Hp(3), Hp(10), Hskin and Hlens. Finally, a software application to interpolate the dose rate per activity due to the beta-emission of arbitrary radionuclides is presented and a simple superposition of these data and of gamma-ray dose constants to calculate the total dose rate is described. (authors)

  4. Beta thalassaemia mutations in Turkish Cypriots.

    OpenAIRE

    Sozuoz, A; Berkalp, A; A. Figus; Loi, A; Pirastu, M.; Cao, A

    1988-01-01

    Using oligonucleotide hybridisation or restriction endonuclease analysis, we have characterised the molecular defect in 94 patients with thalassaemia major and four with thalassaemia intermedia of Turkish Cypriot descent. We found that four mutations, namely beta+ IVS-1 nt 110, beta zero IVS-1 nt, beta+ IVS-1 nt 6, and beta+ IVS-2 nt 745 were prevalent, accounting for 69.9%, 11.7%, 8.7%, and 5.6% respectively of the beta thalassaemia chromosomes. This information may help in the organisation ...

  5. Design and building of an extrapolation ionization chamber for beta dosimetry

    International Nuclear Information System (INIS)

    An extrapolation chamber was designed and built to be used in beta dosimetry. The basic characteristics of an extrapolation chamber are discussed, together with fundamental principle of the dosimetric method used. Details of the chamber's design and properties of materials employed are presented. A full evaluation of extrapolation chamber under irradiation from two 90Sr + 90Y beta sources is done. The geometric parameters of the chamber, leakage current and ion collection efficiency are determined. (Author)

  6. Determination of transmission factors for beta radiation using Al 2O 3:C commercial OSL dosimeters

    Science.gov (United States)

    Pinto, T. N. O.; Caldas, L. V. E.

    2010-07-01

    In recent years, the optically stimulated luminescence (OSL) technique has been used in personal dosimetry, and aluminum oxide (Al 2O 3:C) has become a very useful material for this technique. The objective of this work was the determination of the transmission factors for beta radiation using Al 2O 3:C commercial dosimeters and the OSL method. The obtained results were similar to the transmission factors reported in the beta source calibration certificates.

  7. Plan beta: Core or Cusp?

    CERN Document Server

    Richardson, Thomas; Lehnert, Matt

    2013-01-01

    The inner profile of Dark Matter (DM) halos remains one of the central problems in small-scale cosmology. At present, the problem can not be resolved in dwarf spheroidal galaxies due to a degeneracy between the DM profile and the velocity anisotropy beta of the stellar population. We discuss a method which can break the degeneracy by exploiting 3D positions and 1D line-of-sight (LOS) velocities. With the full 3D spatial information, we can determine precisely what fraction of each stars LOS motion is in the radial and tangential direction. This enables us to infer the anisotropy parameter beta directly from the data. The method is particularly effective if the galaxy is highly anisotropic. Finally, we argue that such a test could be applied to Sagittarius and potentially other dwarfs with RR Lyrae providing the necessary depth information.

  8. Beta spectrum of 185W

    International Nuclear Information System (INIS)

    The measurement of the shape of the first forbidden beta transition of 185W is interesting from the point of view of the fact that this nucleus belongs to the deformed region 150185W is carried out employing an optimized Siegbahn-Slatis beta ray spectrometer and the result is compared with the theoretical shape factor incorporating Nilsson's wavefunctions using Simms formalism. The experimental shape factor is fitted to the correction factor C(W)=k(1+aW) with α=0.0026+-0.0432. The theoretical shape factor computed following the matrix elements due to Nilsson model is in good agreement with the present experimental shape factor. The value Λ(2.358) computed in the present measurement in the light of Nilsson model matrix elements of 185W is in agreement with the predicted value (2.4) of J.J. Fujita. (author)

  9. Dosimetry of β extensive sources

    International Nuclear Information System (INIS)

    In this work, we have been studied, making use of the Penelope Monte Carlo simulation code, the dosimetry of β extensive sources in situations of spherical geometry including interfaces. These configurations are of interest in the treatment of the called cranealfaringyomes of some synovia leisure of knee and other problems of interest in medical physics. Therefore, its application can be extended toward problems of another areas with similar geometric situation and beta sources. (Author)

  10. The Mechanism of $\\beta$-Delayed Two-Proton Emission

    CERN Multimedia

    2002-01-01

    The nucleus $^{31}$Ar seems to be the most prolific ${\\beta}$-2p precursor known to date and is at the same time the one with the largest production yields at ISOLDE, where the most sensitive experiments can be done. Our purpose with this experiment is to study the ${\\beta}$-2p branches in detail, search for ${\\beta}$-3p events, place them in the decay scheme and obtain information on the decay mechanism for ${\\beta}$-2p via the energy distribution and the angular correlation between the two protons. As a by product we shall also resolve existing inconsistencies in the level scheme.\\\\ \\\\ The nucleus $^{31}$Ar, produced in a cold plasma ion source unit by the impact of a 1 GeV proton beam of 0.5 Hz frequency, had an average yield over one week of 1.5 $^{31}$Ar atoms/s. The beam passed through the central hole of an annular Si detector ($\\Omega$ = 4.3~\\%) and stopped in a thin carbon foil tilted 45$^o$ with respect to the beam direction. A 70~\\% coaxial HPGe-detector ($\\Omega$~=~7.4~\\%) was located opposite to ...

  11. Calculating Capstone Depleted Uranium Aerosol Concentrations from Beta Activity Measurements

    International Nuclear Information System (INIS)

    Beta activity measurements were used as surrogate measurements of uranium mass in aerosol samples collected during the field testing phase of the Capstone Depleted Uranium (DU) Aerosol Study. These aerosol samples generated by the perforation of armored combat vehicles were used to characterize the depleted uranium (DU) source term for the subsequent human health risk assessment (HHRA) of Capstone aerosols. Establishing a calibration curve between beta activity measurements and uranium mass measurements is straightforward if the uranium isotopes are in equilibrium with their immediate short-lived, beta-emitting progeny. For DU samples collected during the Capstone study, it was determined that the equilibrium between the uranium isotopes and their immediate short lived, beta-emitting progeny had been disrupted when penetrators had perforated target vehicles. Adjustments were made to account for the disrupted equilibrium and for wall losses in the aerosol samplers. Correction factors for the disrupted equilibrium ranged from 0.16 to 1, and the wall loss correction factors ranged from 1 to 1.92

  12. Abstraction Mechanisms in the BETA Programming Language

    DEFF Research Database (Denmark)

    Kristensen, Bent Bruun; Madsen, Ole Lehrmann; Møller-Pedersen, Birger;

    1983-01-01

    The BETA programming language is developed as part of the BETA project. The purpose of this project is to develop concepts, constructs and tools in the field of programming and programming languages. BETA has been developed from 1975 on and the various stages of the language are documented in [BETA...... a]. The application area of BETA is programming of embedded as well as distributed computing systems. For this reason a major goal has been to develop constructs that may be efficiently implemented. Furthermore the BETA language is intended to have a few number of basic but general constructs...... to SMALLTALK, BETA is a language in the ALGOL 60 ([ALGOL]) family. SIMULA 67 is a system description and a programming language. The DELTA language ([DELTA]) is a system description language only, allowing description of full concurrency, continuous change and component interaction, developed from a SIMULA...

  13. Beta emitters and radiation protection

    DEFF Research Database (Denmark)

    Jødal, Lars

    2009-01-01

    , and 90Y, using data from a freely available database. Bremsstrahlung yields were calculated for 90Y shielded by lead, aluminium, or perspex. Bremsstrahlung spectrum from 90Y shielded by perspex was measured, and attenuation of spectrum by lead was calculated. Whole-body and finger doses to persons...... the outside of the primary shielding material. If suitable shielding is used and larger numbers of handlings are divided among several persons, then handling of beta emitters can be a safe procedure....

  14. Review of double beta experiments

    OpenAIRE

    Sarazin, X.

    2012-01-01

    C13-10-22.1 International audience This paper gives a review of the double beta experimental techniques and projects, in the search for the Majorana neutrino. The purpose of this review is to detail, for each technique, the different origins of background, how they can be identified, and how they can be reduced. Advantages and limitations of the different techniques are discussed. 1. Introduction The neutrino is one of the most puzzling elementary particle with very unique properties. I...

  15. Electrolytic hydrogen in beta titanium

    International Nuclear Information System (INIS)

    Permeation of electrolytic hydrogen through beta titanium foils with palladium coated surfaces was studied using Ti--11.5 Mo--6 Zr--4.5 Sn. Ion bombardment etching followed by thin film vapor deposition of palladium were used to produce oxide-free titanium specimens for electrochemical hydrogen permeation and embrittlement studies. A thin metallic foil is cathodically charged with hydrogen on one side while the other side is maintained at a sufficiently anodic potential so that all the diffusing hydrogen is oxidized and turned into an equivalent current. The current is analyzed to determine diffusivity and solubility of hydrogen. X-ray diffraction was also used to determine the effects of hydrogen on the lattice parameter. Permeation experiments conducted with basic cyanide solutions exhibited simple diffusion behavior. The diffusivity at 210C for hydrogen through the beta alloy was 5.60 (+-1.92) x 10-7 cm2/s. Anomalous permeation occurred with hydrogen chemical potentials in acidic and basic solutions without cyanide during the later stages of the approach to steady state in the charging. This behavior is consistent with the trapping model of hydrogen in metals of McNabb and Foster. Plastic deformation and spontaneous cracking at the wetted portion of the specimen were observed under extreme conditions during this anomalous behavior. Part of the deformation is found to be reversible. In the mandrel bend experiments on the embrittlement phenomenon, the transgranular cleavage mode of fracture occurred. Interstitially dissolved hydrogen expanded the bcc lattice of the beta titanium with accompanying diffraction line broadening. The lattice contracted upon removal of the hydrogen. The satisfactory performance of the beta alloy Ti--11.5 Mo--6 Zr--4.5 Sn, in moderate electrochemical environments results principally from the protective oxide film

  16. Neutrinoless Double Beta Decay Experiments

    OpenAIRE

    Zuber, K.

    2014-01-01

    Neutrinoless double beta decay is the only process known so far able to test the neutrino intrinsic nature: its experimental observation would imply that the lepton number is violated by two units and prove that neutrinos have a Majorana mass components, being their own anti-particle. While several experiments searching for such a rare decay have been performed in the past, a new generation of experiments using different isotopes and techniques have recently released their results or are taki...

  17. Myokardinfarkt und Beta-Blocker

    Directory of Open Access Journals (Sweden)

    Stühlinger H-G

    2003-01-01

    Full Text Available Im Rahmen eines akuten koronaren Syndroms (akuter Herzinfarkt, Angina pectoris kommt es, aufgrund eines Ungleichgewichtes zwischen Angebot und Bedarf, zu einem akuten Mangel an Sauerstoff im Herzmuskel. Ursache ist eine reduzierte Sauerstoffzufuhr durch verengte bzw. verschlossene Gefäße. Bis zur Behebung der Ursache vergehen oft mehrere Stunden. In dieser Phase muß - durch Verminderung des Sauerstoffbedarfs im Herzmuskel - eine Verlangsamung der Nekroseentwicklung erreicht werden. Das Ausmaß der Nekrose wird reduziert, somit die für die Langzeitprognose wichtige Linksventrikelfunktion verbessert. Eine Verminderung des Sauerstoffbedarfs erreicht man durch kontrollierte Frequenzsenkung mittels intravenöser Beta-Blockade. In optimaler Weise wird diese Methode durch die Anwendung eines kardioselektiven Beta-Blockers mit kurzer Halbwertszeit durchgeführt. Beta-Blocker haben nicht nur auf die Nekroseentwicklung, sondern auch auf die Inzidenz von Rhythmusstörungen - besonders in der Akutphase - Auswirkungen. Vor allem die mit dieser therapeutischen Maßnahme verbundene Reduktion von Kammerflimmern ist von großer Bedeutung.

  18. Metalo-beta-lactamases Metallo-beta-lactamases

    Directory of Open Access Journals (Sweden)

    Rodrigo Elisandro Mendes

    2006-04-01

    Full Text Available Nos últimos anos tem sido observada maior incidência de bacilos Gram-negativos resistentes a cefalosporinas de espectro ampliado no ambiente hospitalar, ocasionando, assim, maior uso de betalactâmicos mais potentes, como os carbapenens. A utilização de carbapenens exerce maior pressão seletiva sobre a microbiota hospitalar, o que pode ocasionar aumento da resistência a esses agentes. Entre os mecanismos de resistência a carbapenens mais comumente identificados estão a produção de betalactamases, como, por exemplo, as pertencentes à classe D de Ambler e as que pertencem à classe B de Ambler, ou metalo-beta-lactamases (MbetaL. Essas últimas hidrolisam todos betalactâmicos comercialmente disponíveis, sendo a única exceção o monobactam aztreonam. Desde o início da década de 1990, novos genes que codificam MbetaLs têm sido descritos em microrganismos clinicamente importantes, como Pseudomonas spp., Acinetobacter spp. e membros da família Enterobacteriaceae. O encontro desses microrganismos não-sensíveis a carbapenens pode ser submetido a metodologias fenotípicas para detecção da produção de MbetaL com o intuito de auxiliar a Comissão de Controle de Infecção Hospitalar (CCIH e prevenir a disseminação desses determinantes de resistência, uma vez que genes que codificam MbetaLs estão contidos em estruturas genéticas que propiciam sua mobilidade de forma muito efetiva, sendo então facilmente disseminados.Increase isolation of Gram-negative bacilli resistant to broad-spectrum cephalosporin has been observed during the last few years, thus determining the use of more potent beta-lactams, such as carbapenems. The use of these antimicrobial agents may lead to the emergence of carbapenem resistant Gram-negative bacilli in the nosocomial environment. Carbapenem resistance may be due to the production of Ambler class D beta-lactamase or Ambler class B beta-lactamase, also called metallo-beta-lactamase (MbetaL. Apart from

  19. Effect of tissue inhomogeneity on beta dose calculation

    International Nuclear Information System (INIS)

    Appropriate monoclonal antibodies labeled with beta-emitting nuclides of high specific activity have been suggested for treatment of specific tumors. In a homogeneous medium the radiation dose rate distribution R due to a distributed activity distribution C can be calculated by convolution of the beta dose point kernel of the radionuclide in soft tissue with C. Prototype computer programs using Fast Fourier Transform techniques have been developed to evaluate the three dimensional spatial convolution efficiently. To study the effect of tissue inhomogeneity on R, the authors simulated a soft tissue-bone interface by a polystyrene (PST)-aluminum (A1) interface and considered the backscattering of beta rays from a point source and a plane source of 32P. LiF thermoluminescent dosimeters were used. With the point source at the PST-A1 interface, R at 0-31, 125-156, and 283-314 mg/cm2 separations from the interface were increased by (12 +/- 3)%, (8 +/-2)%, and (3 +/- 2)%, respectively, compared with a PST-PST interface. With the plane source, the increases were (8 +/- 3)%, (6 +/- 3)%, and (5 +/- 5)% for separations of 23-58, 150-184, and 277-311 mg/cm2, respectively. With the point source at a PST-air interface to simulate soft tissue-air interface, R at 0-31, 139-170, and 283-314 mg/cm2 from the interface were decreased by (25 +/- 4)%, (11 +/- 7)%, and (5 +/-2)%, respectively. The changes in R have also been measured with degraded spectra of 32P. Comparison of the experimental data with Monte Carlo calculation and the Two-Group method of calculation will be discussed. 20 references, 6 figures, 2 tables

  20. Alpha and beta dose gradients in tooth enamel

    International Nuclear Information System (INIS)

    New results describing gradients in effective alpha and beta doses within a layer of tooth enamel in planar geometry are presented. The alpha (track) dose to an enamel layer is calculated using an algorithm similar to that of Aitken (Aitken, M.J., 1987. Alpha dose to a thin layer. Ancient TL 5, 1-3.). The code for ROSY version 1.4 incorporates this algorithm. The approach allows for variation of the alpha track dose near the edges of the enamel, and we describe the gradient of the alpha track dose within 40 μm of each edge of the enamel for natural sources. In ESR or luminescence dating of naturally thin layers, for which stripping of the surface layer containing the alpha dose gradients may not be feasible, age estimates may change by as much as 5-10% when the detailed alpha dose calculation is included. Modern Monte Carlo-based results for the variation of beta dose for depths up to 2 mm are compared with ROSY results. For external irradiation by different sources, the attenuation of the ROSY dose estimate with depth is usually less rapid than that of the Monte Carlo-based estimate. The ROSY estimate of average beta dose to a layer in this case is between 5 and 18% higher than the Monte Carlo estimate

  1. On gaps in Rényi $\\beta$-expansions of unity for $\\beta > 1$ an algebraic number.

    OpenAIRE

    Verger-Gaugry, Jean-Louis

    2006-01-01

    Let $\\beta> 1$ be an algebraic number. We study the strings of zeros (“gaps”) in the Rényi $\\beta$ -expansion $d_{\\beta}(1)$ of unity which controls the set $\\mathbb{Z}_{\\beta}$ of $\\beta$-integers. Using a version of Liouville's inequality which extends Mahler's and Güting's approximation theorems, the strings of zeros in $d_{\\beta}(1)$ are shown to exhibit a “gappiness” asymptotically bounded above by $log(M(\\beta ))/ log(\\beta)$, where $M(\\beta)$ is the Mahler measure of $\\beta$ . The proo...

  2. Analysis (Simulation) of Ni-63 beta-voltaic cells based on silicon solar cells

    Science.gov (United States)

    Gorbatsevich, A. A.; Danilin, A. B.; Korneev, V. I.; Magomedbekov, E. P.; Molin, A. A.

    2016-07-01

    Beta-voltaic cells based on standard silicon solar cells with bilateral coating with beta-radiation sources in the form of 63Ni isotope have been studied experimentally and by numerical simulation. The optimal parameters of the cell, including its thickness, the doping level of the substrate, the depth of the p- n junction on its front side, and the p + layer on the back side, as well as the activity of the source material, have been calculated. The limiting theoretical values of the open-circuit voltage (0.26 V), short-circuiting current (2.1 μA), the output power of the cell (0.39 μW), and the efficiency of the conversion of the radioactive energy onto the electric energy (4.8%) have been determined for a beta-source activity of 40 mCi. The results of numerical analysis have been compared with the experimental data.

  3. Resistance training & beta-hydroxy-beta-methylbutyrate supplementation on hormones

    Directory of Open Access Journals (Sweden)

    Hamid Arazi

    2015-10-01

    Full Text Available RESUMOIntroduction:In recent years, there was an increased interest on the effects of beta-hydroxy-beta-methylbutyrate (HMB supplementation on skeletal muscle due to its anti-catabolic effects.Objectives:To investigate the effect of HMB supplementation on body composition, muscular strength and anabolic-catabolic hormones after resistance training.Methods:Twenty amateur male athletes were randomly assigned to supplement and control groups in a double-blind crossover design and participated in four weeks resistance training. Before and after the test period fasting blood samples were obtained to determine anabolic (the growth hormone and testosterone and catabolic (cortisol hormones, and fat mass, lean body mass (LBM and muscular strength were measured. Dependent and independent t-tests were used to analyze data.Results:After the training period, there were no significant differen-ces between the groups with respect to fat mass, LBM and anabolic-catabolic hormones. HMB supplementation resulted in a significantly greater strength gain (p≤0.05.Conclusion:Greater increase in strength for HMB group was not accompanied by body composition and basal circulating anabolic-catabolic hormonal changes. It seems that HMB supplementation may have beneficial effects on neurological adaptations of strength gain.

  4. GSK3beta is involved in JNK2-mediated beta-catenin inhibition.

    Directory of Open Access Journals (Sweden)

    Dong Hu

    Full Text Available BACKGROUND: We have recently reported that mitogen-activated protein kinase (MAPK JNK1 downregulates beta-catenin signaling and plays a critical role in regulating intestinal homeostasis and in suppressing tumor formation. This study was designed to determine whether JNK2, another MAPK, has similar and/or different functions in the regulation of beta-catenin signaling. METHODOLOGY AND PRINCIPAL FINDINGS: We used an in vitro system with manipulation of JNK2 and beta-catenin expression and found that activated JNK2 increased GSK3beta activity and inhibited beta-catenin expression and transcriptional activity. However, JNK2-mediated downregulation of beta-catenin was blocked by the proteasome inhibitor MG132 and GSK3beta inhibitor lithium chloride. Moreover, targeted mutations at GSK3beta phosphorylation sites (Ser33 and Ser37 of beta-catenin abrogated JNK2-mediated suppression of beta-catenin. In vivo studies further revealed that JNK2 deficiency led to upregulation of beta-catenin and increase of GSK3-beta phosphorylation in JNK2-/- mouse intestinal epithelial cells. Additionally, physical interaction and co-localization among JNK2, beta-catenin and GSK3beta were observed by immunoprecipitation, mammalian two-hybridization assay and confocal microscopy, respectively. CONCLUSION AND SIGNIFICANCE: In general, our data suggested that JNK2, like JNK1, interacts with and suppresses beta-catenin signaling in vitro and in vivo, in which GSK3beta plays a key role, although previous studies have shown distinct functions of JNK1 and JNK2. Our study also provides a novel insight into the crosstalk between Wnt/beta-catenin and MAPK JNKs signaling.

  5. Hyper-beta-alaninemia associated with beta-aminoaciduria and gamma-aminobutyricaciduaia, somnolence and seizures.

    Science.gov (United States)

    Scriver, C R; Pueschel, S; Davies, E

    1966-03-24

    Hyper-beta-alaninemia was found in a somnolent, convulsing infant. Hyper-beta-aminoaciduria (beta-ala, betaAIB and taurine) was also observed, varying directly with plasma beta-alanine concentration. The beta-aminoaciduria is explained by the interaction between beta-alanine and a specific cellular-transport system with preference for beta-amino compounds. Gamma-aminobutyricaciduria was also observed, its excretion being independent of beta-alanine levels. Dietary modifications, pyridoxine, pantothenic acid and antibiotic therapy were not beneficial. Post-mortem tissues had elevated levels of beta-alanine and carnosine; GABA levels in brain were probably elevated for the age of the patient. A proposed block in beta-alanine-alpha-ketoglutarate transaminase would expand the free beta-alanine pool, thus increasing tissue carnosine. beta-Alanine is a central-nervous-system depressant. Associated inhibition of GABA transaminase and displacement of GABA from central-nervous-system binding sites would produce GABAuria and convulsions. PMID:17926374

  6. Beta-2-mikroglobulin ved medicinske sygdomme

    DEFF Research Database (Denmark)

    Hansen, P B; Olsen, Niels Vidiendal

    1989-01-01

    Beta-2-microglobulin (beta 2M) is a low-molecular protein which is filtered freely over the glomeruli. Under normal circumstances, more than 99.9% is resorbed in the proximal tubuli of the kidneys and is metabolized there. In renal disease with damage to this segment of the nephron, eg acute tubulo......-interstitial nephropathy, increased quantities of beta 2M are excreted in the urine. If the rate of glomerular filtration is reduced, serum-beta 2M is increased and this is also the case in persons with increased cell division despite normal renal function. Serum-beta 2M is, therefore, raised in numerous malignant...... diseases and reflects the size of the tumour mass. During cytostatic treatment of myelomatosis and chronic lymphatic leukaemia, the serum-beta 2M levels decrease on remission and increase on relapse. In acute leukaemia and malignant lymphoma with infiltration of the CNS, similar conditions prevail for CSF...

  7. GERDA - a new neutrinoless double beta experiment using 76Ge

    Science.gov (United States)

    Meierhofer, G.; GERDA Collaboration

    2011-09-01

    The search for neutrinoless double beta decay (0νßß) has been a very active field for the last decades. While double beta decay has been observed, 0νßß decay still waits for its experimental proof. The GErmanium Detector Array (GERDA) uses 76Ge, an ideal candidate as it is acting as source and detector simultaneously. Germanium detectors, isotopically enriched in 76Ge are submerged directly into an ultra pure cryo liquid, which serves as coolant and radiation shield. This concept will allow to reduce the background by up to two orders of magnitude with respect to earlier experiments. GERDA has been constructed in hall A of the underground laboratory LNGS of the INFN in Italy. The experiment started recently with a test run.

  8. GERDA - a new neutrinoless double beta experiment using 76Ge

    International Nuclear Information System (INIS)

    The search for neutrinoless double beta decay (0νssss) has been a very active field for the last decades. While double beta decay has been observed, 0νssss decay still waits for its experimental proof. The GErmanium Detector Array (GERDA) uses 76Ge, an ideal candidate as it is acting as source and detector simultaneously. Germanium detectors, isotopically enriched in 76Ge are submerged directly into an ultra pure cryo liquid, which serves as coolant and radiation shield. This concept will allow to reduce the background by up to two orders of magnitude with respect to earlier experiments. GERDA has been constructed in hall A of the underground laboratory LNGS of the INFN in Italy. The experiment started recently with a test run.

  9. Precision Study of the $\\beta$-decay of $^{62}$Ga

    CERN Multimedia

    2002-01-01

    It is proposed to perform a precision study of the $\\beta$-decay of $\\,^{62}$Ga taking advantage of recent developments of the ISOLDE Laser Ion Source. The goal is to eventually extend the high-precision knowledge of superallowed $\\beta$-decays beyond the nine decays that presently are used for extracting the V$_{ud}$ quark mixing matrix element of the CKM matrix. The scientific motivations are the current deviation of more than 2$\\sigma$ of the unitary condition of this matrix, which could be an indication of non-standard-model physics, and a test of the theoretical corrections applied to the experimental data. The experiment will utilise the Total Absorption $\\gamma$-ray (TAG) spectrometer in order to determine weak branchings to excited states in $^{62}$Zn and the ISOLDE spectroscopy station to perform half-life measurements and detailed spectroscopy of this nucleus.

  10. Dynamic Hysteresis Probes High-{\\beta} Nanolaser Emission Regimes

    CERN Document Server

    Pan, Si Hui; Amili, Abdelkrim El; Vallini, Felipe; Fainman, Yeshaiahu

    2016-01-01

    The quest for an integrated light source that promises high energy efficiency and fast modulation for high-performance photonic circuits has led to the development of room-temperature telecom-wavelength nanoscale laser with high spontaneous emission factors, \\beta. The coherence characterization of this type of lasers is inherently difficult with the conventional measurement of output light intensity versus input pump intensity due to the diminishing kink in the measurement curve. We demonstrate the transition from chaotic to coherent emission of a high-{\\beta} pulse-pump metallo-dielectric nanolaser can be determined by examining the width of a second order intensity correlation peak, which shrinks below and broadens above threshold. Photon fluctuation study, first one ever reported for this type of nanolaser, confirms the validity of this measurement technique. Additionally, we show that the width variation above threshold results from the delayed threshold phenomenon, providing the first indirect observati...

  11. Radiolytical oxidation of gaseous iodine by beta radiation

    Energy Technology Data Exchange (ETDEWEB)

    Kaerkelae, Teemu; Auvinen, Ari; Kekki, Tommi; Kotiluoto, Petri; Lyyraenen, Jussi [VTT Technical Research Centre of Finland, Espoo (Finland); Jokiniemi, Jorma [VTT Technical Research Centre of Finland, Espoo (Finland); Eastern Finland Univ., Kuopio (Finland)

    2015-07-01

    Iodine is one of the most radiotoxic fission product released from fuel during a severe nuclear power plant accident. Within the containment building, iodine compounds can react e.g. on the painted surfaces and form gaseous organic iodides. In this study, it was found out that gaseous methyl iodide (CH{sub 3}I) is oxidised when exposed to beta radiation in an oxygen containing atmosphere. As a result, nucleation of aerosol particles takes place and the formation of iodine oxide particles is suggested. These particles are highly hygroscopic. They take up water from the air humidity and iodine oxides dissolve within the droplets. In order to mitigate the possible source term, it is of interest to understand the effect of beta radiation on the speciation of iodine.

  12. A combined limit for neutrinoless double-beta decay

    CERN Document Server

    Guzowski, Pawel

    2015-01-01

    The search for neutrinoless double-beta decay is important in determining the Majorana nature of the neutrino, and also in establishing if lepton number is violated. In this work, we combine the published data from five independent neutrinoless double-beta decay experiments: CUORICINO, EXO, GERDA, KamLAND-Zen and NEMO-3. As these experiments use different isotope sources, the relative signal normalisation between them depends on the Nuclear Matrix Element (NME) calculations used. The combined limits for the Majorana neutrino mass for 5 different NME models range from 130-310 meV. The combined mass limits can offer an improvement over the individual experiments of up to 25%, depending on the NME model.

  13. Experiments on double beta decay

    International Nuclear Information System (INIS)

    The Double Beta Decay, and especially (ββ)0ν mode, is an excellent test of Standard Model as well as of neutrino physics. From experimental point of view, a very large number of different techniques are or have been used increasing the sensitivity of this experiments quite a lot (the factor of 104 in the last 20 years). In future, in spite of several difficulties, the sensitivity would be increased further, keeping the interest of this very important process. (author) 4 figs., 5 tabs., 21 refs

  14. Asymmetrically acting lycopene beta-cyclases (CrtLm) from non-photosynthetic bacteria.

    Science.gov (United States)

    Tao, L; Picataggio, S; Rouvière, P E; Cheng, Q

    2004-03-01

    Carotenoids have important functions in photosynthesis, nutrition, and protection against oxidative damage. Some natural carotenoids are asymmetrical molecules that are difficult to produce chemically. Biological production of carotenoids using specific enzymes is a potential alternative to extraction from natural sources. Here we report the isolation of lycopene beta-cyclases that selectively cyclize only one end of lycopene or neurosporene. The crtLm genes encoding the asymmetrically acting lycopene beta-cyclases were isolated from non-photosynthetic bacteria that produced monocyclic carotenoids. Co-expression of these crtLm genes with the crtEIB genes from Pantoea stewartii (responsible for lycopene synthesis) resulted in the production of monocyclic gamma-carotene in Escherichia coli. The asymmetric cyclization activity of CrtLm could be inhibited by the lycopene beta-cyclase inhibitor 2-(4-chlorophenylthio)-triethylamine (CPTA). Phylogenetic analysis suggested that bacterial CrtL-type lycopene beta-cyclases might represent an evolutionary link between the common bacterial CrtY-type of lycopene beta-cyclases and plant lycopene beta- and epsilon-cyclases. These lycopene beta-cyclases may be used for efficient production of high-value asymmetrically cyclized carotenoids. PMID:14740205

  15. Beta blockers: A new role in chemotherapy

    OpenAIRE

    Nagaraja, Archana S; Sadaoui, Nouara C.; Lutgendorf, Susan K.; Ramondetta, Lois M.; Sood, Anil K

    2013-01-01

    Beta-blockers are a class of drugs widely used to treat cardiac, respiratory and other ailments. They act by blocking beta-adrenergic receptor–mediated signalling. Studies in various cancers have shown that patients taking a beta-blocker have higher survival and lower recurrence and metastasis rates. This is supported by several preclinical and in vitro studies showing that adrenergic activation modulates apoptosis, promotes angiogenesis and other cancer hallmarks, and these effects can be ab...

  16. The pancreatic beta cell surface proteome

    OpenAIRE

    Stützer, I.; Esterházy, D.; Stoffel, M.

    2012-01-01

    The pancreatic beta cell is responsible for maintaining normoglycaemia by secreting an appropriate amount of insulin according to blood glucose levels. The accurate sensing of the beta cell extracellular environment is therefore crucial to this endocrine function and is transmitted via its cell surface proteome. Various surface proteins that mediate or affect beta cell endocrine function have been identified, including growth factor and cytokine receptors, transporters, ion channels and prote...

  17. Constructions for a bivariate beta distribution

    OpenAIRE

    Olkin, Ingram; Trikalinos, Thomas A.

    2014-01-01

    The beta distribution is a basic distribution serving several purposes. It is used to model data, and also, as a more flexible version of the uniform distribution, it serves as a prior distribution for a binomial probability. The bivariate beta distribution plays a similar role for two probabilities that have a bivariate binomial distribution. We provide a new multivariate distribution with beta marginal distributions, positive probability over the unit square, and correlations over the full ...

  18. Theoretical aspects of double beta decay

    International Nuclear Information System (INIS)

    Considerable effort has been expended recently in theoretical studies of double beta decay. Much of this work has focussed on the constraints this process places on gauge theories of the weak interaction, in general, and on the neutrino mass matrix, in particular. In addition, interesting nuclear structure questions have arisen in studies of double beta decay matrix elements. After briefly reviewing the theory of double beta decay, some of the progress that has been made in these areas is summarized. 25 references

  19. First forbidden beta decay in light nuclei

    Energy Technology Data Exchange (ETDEWEB)

    Millener, D.J.; Warburton, E.K.

    1984-01-01

    Beta decay matrix elements for the operators sigma dot del and sigma dot r are calculated for eight J/sup +/ ..-->.. J/sup -/ or J/sup -/ ..-->.. J/sup +/ beta transitions. Results using harmonic oscillator wave functions differ markedly from those using more realistic Woods-Saxon wave functions. A substantial contribution to the sigma dot del matrix elements from pion exchange currents is required to reproduce the experimental beta decay rates. 15 references.

  20. First forbidden beta decay in light nuclei

    International Nuclear Information System (INIS)

    Beta decay matrix elements for the operators sigma dot del and sigma dot r are calculated for eight J+ → J- or J- → J+ beta transitions. Results using harmonic oscillator wave functions differ markedly from those using more realistic Woods-Saxon wave functions. A substantial contribution to the sigma dot del matrix elements from pion exchange currents is required to reproduce the experimental beta decay rates. 15 references

  1. The Benchmark Beta, CAPM, and Pricing Anomalies.

    OpenAIRE

    Cheol S. Eun

    1994-01-01

    Recognizing that a part of the unobservable market portfolio is certainly observable, the author first reformulate the capital asset pricing model so that asset returns can be related to the 'benchmark' beta computed against a set of observable assets as well as the 'latent' beta computed against the remaining unobservable assets, and then shows that when the pricing effect of the latent beta is ignored, assets would appear to be systematically mispriced even if the capital asset pricing mode...

  2. C3 polymorphism in beta-thalassemia.

    Science.gov (United States)

    Germenis, A; Kalantzi, M; Karamerou, A; Politi, C; Fertakis, A

    1984-01-01

    The distribution of phenotypes and gene frequencies of the third component of complement (C3) were studied in 106 beta-thalassemic patients and in 112 carriers of the beta-thalassemia trait. A statistically significant association was found between the C3F gene and homozygous beta-thalassemia. It can be suggested that this association may be related with the high incidence of infections encountered in these patients. PMID:6419525

  3. Standardization of (18)F using the 4pi(beta+gamma) integral counting technique.

    Science.gov (United States)

    Yamada, T; Kawada, Y; Sato, Y; Yunoki, A; Hino, Y

    2008-01-01

    Alpha 4pi(beta+gamma) integral counting technique using a 4pibeta-4pigamma detector configuration was adopted for the standardization of (18)F. In this technique, the beta-detector is composed of two thin plastic scintillators sandwiching the source, coupled with a slender photomultiplier tube. The beta-detector part with the source was inserted into a large well-type NaI(Tl) scintillation detector for gamma-ray detection, making a 4pibeta-4pigamma coincidence counting system. In this work, positron particles were detected with high efficiency in the beta-channel and annihilation quanta were also detected with high efficiency in the 4pigamma channel. The very small inefficiency of the 4pi(beta+gamma) integral counter for the beta-plus branch has been confirmed by EGS5 Monte Carlo simulation. The result using this technique agreed within the uncertainties with the result obtained by the conventional 4pibeta-gamma coincidence counting with the efficiency extrapolation technique using the same detector configuration and a conventional 4pibeta-gamma coincidence counter. PMID:18378155

  4. Fabrication of beta particles detector for RMS

    International Nuclear Information System (INIS)

    The beta particles detector for RMS (radiation monitoring system) was fabricated to detect charged beta particles. The plastic scintillator was cutted, shaped, polished to make plastic disk for beta particles. The diameter of completed plastic scintillator disk is 40 mm and thickness is 1.5 mm. The mylar film and aluminium foil were used the front of plastic scintillator to intercept light and moisture. The completed plastic detector for RMS consist of the discriminator and counter were made by ULS (Co.). The absolute efficiency of plastic detector was 45.51% for beta particles (Sr/Y - 90)

  5. Sawtooth crashes at high beta on JET

    Energy Technology Data Exchange (ETDEWEB)

    Alper, B.; Huysmans, G.T.A.; Sips, A.C.C. [Commission of the European Communities, Abingdon (United Kingdom). JET Joint Undertaking; Nave, M.F.F. [Universidade Tecnica, Lisbon (Portugal). Inst. Superior Tecnico

    1994-07-01

    The sawtooth crashes on JET display features which depend on beta. The main observation is a transient bulging of flux surfaces (duration inferior to 30 microsec.), which is predominantly on the low field side and extends to larger radii as beta increases. This phenomenon reaches the plasma boundary when beta{sub N} exceeds 0.5 and in these cases is followed by an ELM within 50 microsec. These sawtooth/ELM events limit plasma performance. Modelling of mode coupling shows qualitative agreement between observations of the structure of the sawtooth precursor and the calculated internal kink mode at high beta. (authors). 6 refs., 5 figs.

  6. $\\beta$-decay study of $^{77}$Cu

    CERN Document Server

    Patronis, N; Górska, M; Huyse, M; Kruglov, K; Pauwels, D; Van de Vel, K; Van Duppen, P; Van Roosbroeck, J; Thomas, J-C; Franchoo, S; Cederkäll, J; Fedosseev, V; Fynbo, H; Georg, U; Jonsson, O; Köster, U; Materna, T; Mathieu, L; Serot, O; Weissman, L; Müller, W F; Mishin, V I; Fedorov, D

    2009-01-01

    A beta-decay study of Cu-77 has been performed at the ISOLDE mass separator with the aim to deduce its beta-decay properties and to obtain spectroscopic information on Zn-77. Neutron-rich copper isotopes were produced by means of proton- or neutron-induced fission reactions on U-238. After the production, Cu-77 was selectively laser ionized, mass separated and sent to different detection systems where beta-gamma and beta-n coincidence data were collected. We report on the deduced half-live, decay scheme, and possible spin assignment of 77Cu.

  7. Milk Intolerance, Beta-Casein and Lactose

    Directory of Open Access Journals (Sweden)

    Sebely Pal

    2015-08-01

    Full Text Available True lactose intolerance (symptoms stemming from lactose malabsorption is less common than is widely perceived, and should be viewed as just one potential cause of cows’ milk intolerance. There is increasing evidence that A1 beta-casein, a protein produced by a major proportion of European-origin cattle but not purebred Asian or African cattle, is also associated with cows’ milk intolerance. In humans, digestion of bovine A1 beta-casein, but not the alternative A2 beta-casein, releases beta-casomorphin-7, which activates μ-opioid receptors expressed throughout the gastrointestinal tract and body. Studies in rodents show that milk containing A1 beta-casein significantly increases gastrointestinal transit time, production of dipeptidyl peptidase-4 and the inflammatory marker myeloperoxidase compared with milk containing A2 beta-casein. Co-administration of the opioid receptor antagonist naloxone blocks the myeloperoxidase and gastrointestinal motility effects, indicating opioid signaling pathway involvement. In humans, a double-blind, randomized cross-over study showed that participants consuming A1 beta-casein type cows’ milk experienced statistically significantly higher Bristol stool values compared with those receiving A2 beta-casein milk. Additionally, a statistically significant positive association between abdominal pain and stool consistency was observed when participants consumed the A1 but not the A2 diet. Further studies of the role of A1 beta-casein in milk intolerance are needed.

  8. Milk Intolerance, Beta-Casein and Lactose

    OpenAIRE

    Sebely Pal; Keith Woodford; Sonja Kukuljan; Suleen Ho

    2015-01-01

    True lactose intolerance (symptoms stemming from lactose malabsorption) is less common than is widely perceived, and should be viewed as just one potential cause of cows’ milk intolerance. There is increasing evidence that A1 beta-casein, a protein produced by a major proportion of European-origin cattle but not purebred Asian or African cattle, is also associated with cows’ milk intolerance. In humans, digestion of bovine A1 beta-casein, but not the alternative A2 beta-casein, releases beta-...

  9. Milk Intolerance, Beta-Casein and Lactose.

    Science.gov (United States)

    Pal, Sebely; Woodford, Keith; Kukuljan, Sonja; Ho, Suleen

    2015-09-01

    True lactose intolerance (symptoms stemming from lactose malabsorption) is less common than is widely perceived, and should be viewed as just one potential cause of cows' milk intolerance. There is increasing evidence that A1 beta-casein, a protein produced by a major proportion of European-origin cattle but not purebred Asian or African cattle, is also associated with cows' milk intolerance. In humans, digestion of bovine A1 beta-casein, but not the alternative A2 beta-casein, releases beta-casomorphin-7, which activates μ-opioid receptors expressed throughout the gastrointestinal tract and body. Studies in rodents show that milk containing A1 beta-casein significantly increases gastrointestinal transit time, production of dipeptidyl peptidase-4 and the inflammatory marker myeloperoxidase compared with milk containing A2 beta-casein. Co-administration of the opioid receptor antagonist naloxone blocks the myeloperoxidase and gastrointestinal motility effects, indicating opioid signaling pathway involvement. In humans, a double-blind, randomized cross-over study showed that participants consuming A1 beta-casein type cows' milk experienced statistically significantly higher Bristol stool values compared with those receiving A2 beta-casein milk. Additionally, a statistically significant positive association between abdominal pain and stool consistency was observed when participants consumed the A1 but not the A2 diet. Further studies of the role of A1 beta-casein in milk intolerance are needed. PMID:26404362

  10. Atmospheric deposition of long-lived Beta radionuclides over the territory of Bulgaria during the last decades

    International Nuclear Information System (INIS)

    The sources of atmospheric radioactivity are discussed and compared. Radon isotopes and their daughters' dominate the natural background of beta activity in the surface air. The man-made radionuclides, much of them beta emitters, started to contaminate regionally and globally the environment after 1940's due to the atmospheric nuclear bomb tests. Additional significant sources of technogenic radionuclides in the atmosphere were nuclear accidents with pronounced examples of Chernobyl and Fukushima. The Bulgarian network for atmospheric radioactivity monitoring has been developing since 1959 in the frame of the state Hydro-meteorological service, now National Institute of Meteorology and Hydrology. It includes daily measurements of aerosol beta activity and deposition immediately and 120h after the sampling. The time and space variations of deposited beta activity, based on long term data records are presented and impact assessment of the different sources is given. The role of precipitation in deposition of radionuclides is evaluated. (author)

  11. Biodisponibilidade do beta-caroteno da folha desidratada de mandioca (Manihot esculenta Crantz Bioavailability of beta-carotene in dehydrated cassava leaves (manihot esculenta Crantz

    Directory of Open Access Journals (Sweden)

    Claudia Isabel Ortega-Flores

    2003-12-01

    Full Text Available Com o objetivo de verificar a biodisponibilidade do beta-caroteno da folha de mandioca (Manihot esculenta Crantz foi realizado um ensaio biológico baseado no modelo de esgotamento das reservas hepáticas de vitamina A em ratos. Um grupo de ratos depletados de vitamina A hepática recebeu folha desidratada de mandioca como fonte beta-caroteno durante 25 dias, e foram comparados com um grupo que recebeu ração com vitamina A, outro grupo com ração sem vitamina A e um último grupo com beta-caroteno. O grupo Zero foi constituído de 8 animais que receberam durante 15 dias ração à base de caseína, deficiente de vitamina A. Ao final do experimento todos os animais foram sacrificados e seus fígados e plasmas analisados por Cromatografia Líquida de Alta Eficiência (CLAE, sendo verificado que a biodisponibilidade do beta-caroteno da folha desidratada de mandioca foi baixa.The biological availability of beta-carotene in cassava leaves (Manihot esculenta Crantz, was verified by means of an assay based on the hepatic depletion of vitamin A reserves model in rats. Rats depleted of hepatic vitamin A received dehydrated cassava leaves as beta-carotene source for 25 days and were compared to groups that received diets with vitamin A, beta-carotene and without vitamin A. The Zero group was formed of 8 animals that received a diet based on casein, lacking vitamin A, during 15 days. At the end of the experiment, all animals were killed and their livers, serum and feces were analyzed by high performance liquid chromatography (HPLC, and it was verified that the bioavailability of beta-carotene of dehydrated cassava leaves was lower.

  12. Is Transforming Stem Cells to Pancreatic Beta Cells Still the Holy Grail for Type 2 Diabetes?

    Science.gov (United States)

    Kahraman, Sevim; Okawa, Erin R; Kulkarni, Rohit N

    2016-08-01

    Diabetes is a progressive disease affecting millions of people worldwide. There are several medications and treatment options to improve the life quality of people with diabetes. One of the strategies for the treatment of diabetes could be the use of human pluripotent stem cells or induced pluripotent stem cells. The recent advances in differentiation of stem cells into insulin-secreting beta-like cells in vitro make the transplantation of the stem cell-derived beta-like cells an attractive approach for treatment of type 1 and type 2 diabetes. While stem cell-derived beta-like cells provide an unlimited cell source for beta cell replacement therapies, these cells can also be used as a platform for drug screening or modeling diseases. PMID:27313072

  13. Angular dependence of thermoluminescent dosemeters for gamma and beta radiation in nuclear medicine

    International Nuclear Information System (INIS)

    The gamma and beta radiation sources are widely used in Nuclear Medicine for diagnostic and therapeutic purposes. Workers of these services receive dose of whole body and end due to the activities of the therapeutic dose preparation and testing, administration radiopharmaceuticals and obtention of image. Hands receive higher doses than other parts of the body. Currently the individual monitoring for the gamma radiation is already well established; However, the determination of the dose due to beta radiation still faces some difficulties. In this work it was studied the angular dependence of thermoluminescent dosemeters detectors in beams of gamma and beta radiation. Detectors of CaSO4:Dy + Teflon produced at IPEN - the Brazilian Institute for Nuclear and Energy Researches - were used. The angular dependence was studied varying the angle between 0 and 180 deg. The results obtained proved to be suitable for use in individual monitoring of workers exposed to beta and gamma radiation

  14. Optimization of Plastic Scintillator Thicknesses for Online Beta Detection in Mixed Fields

    International Nuclear Information System (INIS)

    For efficient beta detection in a mixed beta-gamma field, Monte Carlo simulation models have been developed to optimize the thickness of a plastic scintillator used in whole body monitor. The simulation has been performed using MCNP/X code and different thicknesses of plastic scintillators ranging from 150 to 600 μm have been used. The relationship between the thickness of the scintillator and the efficiency of the detector has been analysed. For 150 μm thickness, an experimental investigation has been conducted with different beta sources at different positions on the scintillator and the counting efficiency of the unit has been measured. Evaluated data along with experimental ones have been discussed. A thickness of 300 μm to 500 μm has been found to be an optimum thickness for better beta detection efficiency in the presence of low energy gamma ray. (author)

  15. [Production and some properties of a beta-glucanase from Trichoderma sp. GXC].

    Science.gov (United States)

    Sun, J; Li, W; Gu, S

    2001-08-01

    The factors affecting Trichoderma sp. GXC for beta-glucanase (1,3-1,4-beta-D-glucan 4-glucanohydrolase, EC 3.2.1.73) production have been investigated, the optimal conditions were that carbon and nitrogen sources were bran and ammonium sulfate, respectively, initial pH 4.0-5.0, shaken at 30 degrees C for 44 h. beta-glucanase was purified to electrophoretic homogeneity by using ammonium sulfate precipitation, Sephadex G-100 and DEAE-Sephadex A-50 chromatography. It's molecular weight was 35 kD by SDS-PAGE, and the enzyme functioned optimally at pH6.0 and 50 degrees C, respectively. In addition, the enzyme was stable at pH 4.0-5.0 and below 40 degrees C. The beta-glucanase activity was significantly inhibited by Fe3+ and stimulated by Co2+, respectively. PMID:12552912

  16. Pion beta decay at PILAC

    International Nuclear Information System (INIS)

    The proposal to build PILAC presents the possibility of making an improved measurement of the pion beta decay rate. The rate for the decay π+ → π0e+νe is predicted by the Standard Model (SM) to be R(π+ → π0e+νe) = 0.3999 ± 0.0005 s-1. The best experimental number, from LAMPF Experiment 32, using in-flight decays, is R(π+ → π0e+νe) = 0.394 ± 0.0015 s-1. A precise measurement would test the SM by testing the unitarity of the Cabibbo- Kobayashi-Maskawa matrix, for which one analysis of the nuclear beta decay data has shown a 0.4% discrepancy. Thus an experiment at the 0. 2% level would be a significant one. Detailed study of possible designs will be needed, as well as extensive testing of components. The reduction of systematic errors to the 0.1% level can only be done over a period of years with a highly stable apparatus and beam. At a minimum, three years of occupancy of a beam line, with 800 hours per year, would be required. 23 refs., 2 figs., 2 tabs

  17. Challenges in Double Beta Decay

    Directory of Open Access Journals (Sweden)

    Oliviero Cremonesi

    2014-01-01

    Full Text Available In the past ten years, neutrino oscillation experiments have provided the incontrovertible evidence that neutrinos mix and have finite masses. These results represent the strongest demonstration that the electroweak Standard Model is incomplete and that new Physics beyond it must exist. In this scenario, a unique role is played by the Neutrinoless Double Beta Decay searches which can probe lepton number conservation and investigate the Dirac/Majorana nature of the neutrinos and their absolute mass scale (hierarchy problem with unprecedented sensitivity. Today Neutrinoless Double Beta Decay faces a new era where large-scale experiments with a sensitivity approaching the so-called degenerate-hierarchy region are nearly ready to start and where the challenge for the next future is the construction of detectors characterized by a tonne-scale size and an incredibly low background. A number of new proposed projects took up this challenge. These are based either on large expansions of the present experiments or on new ideas to improve the technical performance and/or reduce the background contributions. In this paper, a review of the most relevant ongoing experiments is given. The most relevant parameters contributing to the experimental sensitivity are discussed and a critical comparison of the future projects is proposed.

  18. Association of heterocellular HPFH, beta(+)-thalassaemia, and delta beta(0)-thalassaemia: haematological and molecular aspects.

    OpenAIRE

    Cianetti, L; Care, A; Sposi, N M; Giampaolo, A; Calandrini, M; Petrini, M.; Massa, A.; Marinucci, M.; Mavilio, F; Ceccanti, M.

    1984-01-01

    An Italian family in which heterocellular hereditary persistence of fetal haemoglobin (HPFH) interacts with both beta(+)- and delta beta-thalassaemia is described. The index case was an 8 year old girl who was presumed to inherit both heterocellular HPFH and beta (+)-thalassaemia from her mother and delta beta-thalassaemia from her father. She was healthy and never needed blood transfusions. The possible contribution of heterocellular HPFH to the less severe expression of the compound delta b...

  19. Clusters of conserved beta cell marker genes for assessment of beta cell phenotype.

    Directory of Open Access Journals (Sweden)

    Geert A Martens

    Full Text Available BACKGROUND AND METHODOLOGY: The aim of this study was to establish a gene expression blueprint of pancreatic beta cells conserved from rodents to humans and to evaluate its applicability to assess shifts in the beta cell differentiated state. Genome-wide mRNA expression profiles of isolated beta cells were compared to those of a large panel of other tissue and cell types, and transcripts with beta cell-abundant and -selective expression were identified. Iteration of this analysis in mouse, rat and human tissues generated a panel of conserved beta cell biomarkers. This panel was then used to compare isolated versus laser capture microdissected beta cells, monitor adaptations of the beta cell phenotype to fasting, and retrieve possible conserved transcriptional regulators. PRINCIPAL FINDINGS: A panel of 332 conserved beta cell biomarker genes was found to discriminate both isolated and laser capture microdissected beta cells from all other examined cell types. Of all conserved beta cell-markers, 15% were strongly beta cell-selective and functionally associated to hormone processing, 15% were shared with neuronal cells and associated to regulated synaptic vesicle transport and 30% with immune plus gut mucosal tissues reflecting active protein synthesis. Fasting specifically down-regulated the latter cluster, but preserved the neuronal and strongly beta cell-selective traits, indicating preserved differentiated state. Analysis of consensus binding site enrichment indicated major roles of CREB/ATF and various nutrient- or redox-regulated transcription factors in maintenance of differentiated beta cell phenotype. CONCLUSIONS: Conserved beta cell marker genes contain major gene clusters defined by their beta cell selectivity or by their additional abundance in either neural cells or in immune plus gut mucosal cells. This panel can be used as a template to identify changes in the differentiated state of beta cells.

  20. In vivo evaluation of expression of TGF{beta}1 in the irradiated heart; Expressao da proteina TGF{beta}1 em coracao irradiado in vivo

    Energy Technology Data Exchange (ETDEWEB)

    Affonso Junior, Renato Jose [Universidade Federal de Sao Paulo (UNIFESP), SP (Brazil). Escola Paulista de Medicina. Dept. Diagnostico por Imagem; Oshima, Celina Tizuko Fujiyama; Silva, Maria Regina Regis [Universidade Federal de Sao Paulo (UNIFESP), SP (Brazil). Escola Paulista de Medicina. Setor de Anatomia Patologica; Kimura, Edna Teruko [Sao Paulo Univ., SP (Brazil). Inst. de Ciencias Biomedicas. Dept. de Histologia; Egami, Mizue Imoto [Universidade Federal de Sao Paulo (UNIFESP), SP (Brazil). Escola Paulista de Medicina. Dept. de Morfologia; Segreto, Roberto Araujo; Segreto, Helena Regina Comodo [Universidade Federal de Sao Paulo (UNIFESP), SP (Brazil). Escola Paulista de Medicina. Setor de Radioterapia]. E-mail: hrcs.dmed@unifesp.epm.br

    2004-04-01

    The objectives of this study were to assess the latent and active TGF{beta}1 localization in the heart, to evaluate whether or not radiation induces latent TGF{beta}1 activation, and to study the distribution of collagen fibers in the irradiated heart. Thirty-two C 57 BL mice were randomly assigned in two groups: GI (non irradiated animals) and GII (irradiated animals). The mice from G II received a single whole-body radiation dose of 7 Gy, using a {sup 60}Co source at a dose rate of 0.97 Gy/min. The animals were sacrificed by cervical dislocation at 1, 14, 30 and 90 days after irradiation. The irradiated hearts showed: nuclear changes and muscle cells with decreased striations; significant increase in the collagen deposition 90 days after irradiation; latent TGF{beta}1 activation in the cardio myocytes and connective tissue cells after irradiation. Our results show the importance of TGF{beta}1 protein in the process of radiation-induced heart fibrosis and suggest that cardio myocytes and connective cells may play a role in this mechanism acting as cellular sources of active TGF{beta}1. (author)

  1. An imidazoline compound completely counteracts interleukin-1[beta] toxic effects to rat pancreatic islet [beta] cells

    DEFF Research Database (Denmark)

    Papaccio, Gianpaolo; Nicoletti, Ferdinando; Pisanti, Francesco A; Galdieri, Michela; Bendtzen, Klaus

    2002-01-01

    In vitro studies have demonstrated that interleukin (IL)-1beta decreases insulin and DNA contents in pancreatic islet beta cells, causing structural damage, that it is toxic to cultured human islet beta cells and that it is able to induce apoptosis in these cells....

  2. Expressions of GSK-3beta, Beta-Catenin and PPAR-Gamma in Medulloblastoma

    Institute of Scientific and Technical Information of China (English)

    Xiong Zhang; Lu Si; Yu Li; Can Mi

    2009-01-01

    Objective: To investigate the expressions of GSK-3beta, Beta-catenin and PPAR-gamma, and their relationship in medulloblastoma, and to explore their value in clinic application.Methods: Immunohistochemical staining with SP method was conducted to determine the expressions of GSK-3beta, Beta-catenin and PPAR-gamma in 48 cases of medulloblastoma and 10 normal cerebellar tissues.Results: The rate of abnormal expressions of beta-catenin and PPAR-gamma in MB was higher than that in normal. Conversely, GSK-3beta in MB was lower than that in the normal (P<0.05). Furthermore, in medulloblastoma, beta-catenin and GSK-3beta showed a negative correlation, PPAR-gamma and beta-catenin had a positive correlation.Conclusion: Abnormal expression of beta-catenin plays a crucial role in the development of medulloblastoma. Meanwhile, PPAR-gamma and GSK-3beta which are tightly related with beta-catenin are both involved in the genesis and development of medulloblastoma.

  3. Evaluation of the instrument correction factors needed in beta dosimetry

    International Nuclear Information System (INIS)

    Generally, the same survey instruments used for the measurement of gamma dose rates are used for monitoring beta fields by making measurements with and without a shield over the detector to separate the penetrating and nonpenetrating components of the radiation field. Survey meters are calibrated using fields that uniformly irradiate the detector volume with the center of the volume used as a reference point. However, under field survey conditions, sources are frequently encountered that have irregular shape and large or small dimensions compared with the detector volume. When the distance from the source to the detector volume (reference point) is small such sources produce non-uniform radiation fields in the detector. Similarly, low energy beta sources cause non-uniform irradiation of the volume due to attenuation of the radiation. In addition, when survey meters are used close to the source, the surveyor is generally interested in dose rates at contact or within a few centimeters of the source. In these cases the reference point is the center front surface of the detector. The resulting readings from such fields are based on an average of the uneven distribution of energy deposition occurring within the detector. In general, this reading would be significantly less than the actual dose existing at the surface of the meter entrance window. To compensate for this discrepancy, correction factors are applied to the readings to give the actual dose. These factors can be in excess of a factor of 100. This paper summarizes observations on energy, angular and source geometry response of survey instruments

  4. Imperfect World of beta beta-decay Nuclear Data Sets

    Energy Technology Data Exchange (ETDEWEB)

    Pritychenko, B. [Brookhaven National Lab. (BNL), Upton, NY (United States). NNDC

    2015-01-03

    The precision of double-beta ββ-decay experimental half lives and their uncertainties is reanalyzed. The method of Benford's distributions has been applied to nuclear reaction, structure and decay data sets. First-digit distribution trend for ββ-decay T2v1/2 is consistent with large nuclear reaction and structure data sets and provides validation of experimental half-lives. A complementary analysis of the decay uncertainties indicates deficiencies due to small size of statistical samples, and incomplete collection of experimental information. Further experimental and theoretical efforts would lead toward more precise values of-decay half-lives and nuclear matrix elements.

  5. Regulation of lactose catabolism in Streptococcus mutans: purification and regulatory properties of phospho-beta-galactosidase.

    Science.gov (United States)

    Calmes, R; Brown, A T

    1979-01-01

    Phospho-beta-galactosidase (P-beta-gal), the enzyme which catalyzes the first step in the metabolism of intracellular lactose phosphate, occurred at high specific activity in the cytoplasm in 12 of 13 strains of streptococcus mutans grown on lactose but not other carbon sources. The P-beta-gal from S. mutans SL1 was purified 13-fold using diethylaminoethyl-cellulose ion exchange and agarose A--0.5 M molecular exclusion column chromatography. The molecualr weight of the enzyme was estimated to be 40,000, and its pH optimum was 6.5 in three different buffer systems. P-beta-gal activity was inhibited by Co2+, Zn2+, and Cu2+, but other cations, ethylenediaminetetraacetic acid, orthophosphate, and fluoride had no effect upon enzyme activity. The kinetic response of P-beta-gal to a model substrate, o-nitrophenyl-beta-D-galactopyranoside-6-phosphate, obeyed Michaelis-Menten kinetics, and the Km for this substrate was 0.19 mM. In addition to being under genetic control, P-beta-gal activity was regulated by a number of biologically active metabolites. Enzyme activity was inhibited in a sigmoidal fashion by phosphoenolpyruvate. The M 0.5 V value for phosphoenolpyruvate was 2.8 mM, and the Hill coefficient (n) was 3. In addition, P-beta-gal exhibited strong inhibition by ATP, galactose-6-phosphate, and glucose-6-phosphate. In contrast to inhibition of P-beta-gal activity by phosphoenolpyruvate, the inhibition exerted by ATP, galactose-6-phosphate, and glucose-6-phosphate obeyed classical Michaelis-Menten kinetics; the Ki values for these inhibitors were 0.55, 1.6, and 4.0 mM, respectively. PMID:33899

  6. [Hemoglobin C -- beta-thalassemia disease and homozygous beta-thalassemia in a black African family (author's transl)].

    Science.gov (United States)

    Basset, P; Fall, M; Oudart, J L

    1975-01-01

    The study of a Malian family has allowed to prove existence of two types of beta-thalassemia genes: the beta0 gene which suppresses the synthesis of the beta chain into cis position and the beta+ gene which slows down only partially this synthesis. The difference between this two genes has been possible owing to the hemoglobin C found in this family and induced by the betaC mutated gene. The segregation of the four genes betaA, betaC, beta0 thal, and beta+ thal. has allowed to compare all the possible phenotypes deriving from the combinations by two of these allelic genes. PMID:128735

  7. Search for beta sup - and beta sup -beta sup - decays of sup 4 sup 8 Ca

    CERN Document Server

    Bakalyarov, A; Barabash, A; Briançon, C; Brudanin, V; Egorov, V; Hubert, F; Hubert, P; Kovalik, A; Lebedev, V I; Rukhadze, N I; Stekl, I; Umatov, V; Vylov, T D

    2002-01-01

    A sup 4 sup 8 CaCO sub 3 powder sample containing 20.18 g of sup 4 sup 8 Ca was measured for 797 h with a 400 cm sup 3 low-background HPGe detector. New limits on decays of sup 4 sup 8 Ca were obtained. For single beta transitions to sup 4 sup 8 Sc the limits are equal to 0.71x10 sup 2 sup 0 y, 1.1x10 sup 2 sup 0 y, and 0.82x10 sup 2 sup 0 y for transitions to the ground state, excited 5 sup + and 4 sup + states, respectively. The new limits on double beta decay to excited states of sup 4 sup 8 Ti are equal to 0.47x10 sup 2 sup 0 y, 1.1x10 sup 2 sup 0 y, and 0.90x10 sup 2 sup 0 y for transitions to the first 2 sup + , second 2 sup + and first 0 sup + excited states, respectively. All limits are given at the 90% CL.

  8. Estimation of the response of ion chamber detectors to beta radiation

    International Nuclear Information System (INIS)

    A technique was developed to calculate the response of cylindrical ion chambers to large area beta sources. Beta particles were simulated as vectors originating from a point on a source plane. Response calculations were performed for various source-plane-to-detector distances. The data testified to the dependency of response on source position and size. The results were compared with measured data. The technique was then used to evaluate the response characteristics of two chamber designs. Results showed that a design with concentric dual chambers could provide a means to estimate source geometry and distance. In addition, a detector employing stacked thin chambers could directly measure the extent of non-uniform ionisation in the chamber. (author)

  9. Signaling from beta1- and beta2-adrenergic receptors is defined by differential interactions with PDE4

    DEFF Research Database (Denmark)

    Richter, Wito; Day, Peter; Agrawal, Rani; Bruss, Matthew D; Granier, Sébastien; Wang, Yvonne L; Rasmussen, Søren Gøgsig Faarup; Horner, Kathleen; Wang, Ping; Lei, Tao; Patterson, Andrew J; Kobilka, Brian; Conti, Marco

    2008-01-01

    Beta1- and beta2-adrenergic receptors (betaARs) are highly homologous, yet they play clearly distinct roles in cardiac physiology and pathology. Myocyte contraction, for instance, is readily stimulated by beta1AR but not beta2AR signaling, and chronic stimulation of the two receptors has opposing...

  10. Beta cell proliferation and growth factors

    DEFF Research Database (Denmark)

    Nielsen, Jens Høiriis; Svensson, C; Møldrup, Annette;

    1999-01-01

    Formation of new beta cells can take place by two pathways: replication of already differentiated beta cells or neogenesis from putative islet stem cells. Under physiological conditions both processes are most pronounced during the fetal and neonatal development of the pancreas. In adulthood litt...

  11. Beta-agonists and animal welfare

    Science.gov (United States)

    The use of beta-agonists in animal feed is a high profile topic within the U.S. as consumers and activist groups continue to question its safety. The only beta-agonist currently available for use in swine is ractopamine hydrochloride (RAC). This is available as Paylean™ (Elanco Animal Health – FDA a...

  12. Dosimetry of Low-Energy Beta Radiation

    DEFF Research Database (Denmark)

    Borg, Jette

    Useful techniques and procedures for derermination of absorbed doses from exposure in a low-energy beta radiation were studied and evaluated. The four techniques included were beta spectrometry, extrapolation chamber dosimetry, Monte Carlo (MC) calculations, and exoelectron dosimetry. As a typical...

  13. Beta spectra. II-Positron spectra

    International Nuclear Information System (INIS)

    Using the Fermi theory of beta decay, the beta spectra for 30 positron emitters have been computed, introducing a correction factor for unique forbidden transitions. The spectra are ploted vs. energy, once normalised, and tabulated with the related Fermi functions. The average and median energies are calculated. (author)

  14. A proportional-scintillation counter beta spectrometer

    International Nuclear Information System (INIS)

    Using a proportional counter for coincidence gating of events in a plastic scintillator provides selective registration of beta interactions in the scintillator. This technique has been used to construct a field instrument that can selectively collect beta spectra (coincidence gating) or gamma spectra (anticoincidence gating). Associated dose rates are calculated from the spectra

  15. Broad resonances and beta-decay

    DEFF Research Database (Denmark)

    Riisager, K.; Fynbo, H. O. U.; Hyldegaard, S.;

    2015-01-01

    Beta-decay into broad resonances gives a distorted lineshape in the observed energy spectrum. Part of the distortion arises from the phase space factor, but we show that the beta-decay matrix element may also contribute. Based on a schematic model for p-wave continuum neutron states it is argued...

  16. Adaptive changes in pancreatic beta cell fractional area and beta cell turnover in human pregnancy

    OpenAIRE

    Butler, A. E.; Cao-Minh, L.; Galasso, R; Rizza, R. A.; Corradin, A.; Cobelli, C; Butler, P C

    2010-01-01

    Aims/hypothesis We sought to establish the extent and basis for adaptive changes in beta cell numbers in human pregnancy. Methods Pancreas was obtained at autopsy from women who had died while pregnant (n = 18), post-partum (n = 6) or were not pregnant at or shortly before death (controls; n = 20). Pancreases were evaluated for fractional pancreatic beta cell area, islet size and islet fraction of beta cells, beta cell replication (Ki67) and apoptosis (TUNEL), and indirect markers of beta cel...

  17. Transition-edge microcalorimeter for tritium beta decay

    International Nuclear Information System (INIS)

    We are conducting a new tritium beta-decay experiment using a cryogenic microcalorimeter. The microcalorimeter consists of a copper foil with an implanted tritium source. The foil is soldered to a thin film gold pad on a silicon wafer that is in thermal contact with an aluminum/silver bilayer transition-edge sensor. The device is voltage biased with current pulses read out using a SQUID magnetometer. The device has been tested with external sources as well as an implanted tritium source. The device is currently too slow to set a meaningful limit on the square of the neutrino mass, but can be made fast enough to set a limit on the order of 10 eV

  18. Antibodies against chromosomal beta-lactamase

    DEFF Research Database (Denmark)

    Giwercman, B; Rasmussen, J W; Ciofu, Oana; Clemmentsen, I; Schumacher, H; Høiby, N

    1994-01-01

    A murine monoclonal anti-chromosomal beta-lactamase antibody was developed and an immunoblotting technique was used to study the presence of serum and sputum antibodies against Pseudomonas aeruginosa chromosomal group 1 beta-lactamase in patients with cystic fibrosis (CF). The serum antibody...... response was studied with serum samples collected in 1992 from 56 CF patients in a cross-sectional study and with serum samples from 18 CF patients in a longitudinal study. Anti-beta-lactamase immunoglobulin G antibodies were present in all of the serum samples from the patients with chronic...... bronchopulmonary P. aeruginosa infection (CF + P) but in none of the CF patients with no or intermittent P. aeruginosa infection. Anti-beta-lactamase antibodies were present in serum from CF + P patients after six antipseudomonal courses (median) and correlated with infection with a beta-lactam-resistant strain of...

  19. The search for neutrinoless double beta decay

    CERN Document Server

    Gomez-Cadenas, J J; Mezzetto, M; Monrabal, F; Sorel, M

    2011-01-01

    In the last few years the search for neutrinoless double beta decay has evolved from being almost a marginal activity in neutrino physics to one of the highest priorities for understanding neutrinos and the origin of mass. There are two main reasons for this paradigm shift: the discovery of neutrino oscillations, which clearly established the existence of massive neutrinos; and the existence of an unconfirmed, but not refuted, claim of evidence for neutrinoless double decay in 76Ge. As a consequence, a new generation of experiments, employing different detection techniques and {\\beta}{\\beta} isotopes, is being actively promoted by experimental groups across the world. In addition, nuclear theorists are making remarkable progress in the calculation of the neutrinoless double beta decay nuclear matrix elements, thus eliminating a substantial part of the theoretical uncertainties affecting the particle physics interpretation of this process. In this report, we review the main aspects of the double beta decay pro...

  20. Simultaneous beta/gamma digital spectroscopy

    Science.gov (United States)

    Farsoni, Abdollah T.

    A state-of-the-art radiation detection system for simultaneous spectroscopy of beta-particles and gamma-rays has been developed. The system utilizes a triple-layer phoswich detector and a customized Digital Pulse Processor (DPP) built in our laboratory. The DPP board was designed to digitally capture the analog signal pulses and, following several digital preprocessing steps, transfer valid pulses to the host computer for further digital processing. A MATLAB algorithm was developed to digitally discriminate beta and gamma events and reconstruct separate beta and gamma-ray energy spectra with minimum crosstalk. The spectrometer proved to be an effective tool for recording separate beta and gamma-ray spectra from mixed radiation fields. The system as a beta-gamma spectrometer will have broad-ranging applications in nuclear non-proliferation, radioactive waste management, worker safety, systems reliability, dose assessment, and risk analysis.

  1. Genetics Home Reference: dopamine beta-hydroxylase deficiency

    Science.gov (United States)

    ... Genetics Home Health Conditions dopamine beta-hydroxylase deficiency dopamine beta-hydroxylase deficiency Enable Javascript to view the ... boxes. Print All Open All Close All Description Dopamine beta (β)-hydroxylase deficiency is a condition that ...

  2. Clusters of conserved beta cell marker genes for assessment of beta cell phenotype

    DEFF Research Database (Denmark)

    Martens, Geert A; Jiang, Lei; Hellemans, Karine H;

    2011-01-01

    of a large panel of other tissue and cell types, and transcripts with beta cell-abundant and -selective expression were identified. Iteration of this analysis in mouse, rat and human tissues generated a panel of conserved beta cell biomarkers. This panel was then used to compare isolated versus laser......The aim of this study was to establish a gene expression blueprint of pancreatic beta cells conserved from rodents to humans and to evaluate its applicability to assess shifts in the beta cell differentiated state. Genome-wide mRNA expression profiles of isolated beta cells were compared to those...... capture microdissected beta cells, monitor adaptations of the beta cell phenotype to fasting, and retrieve possible conserved transcriptional regulators....

  3. The MAJORANA Neutrinoless Double-Beta Decay Experiment

    International Nuclear Information System (INIS)

    Majorana collaboration paper for the IEEE Nuclear Science Symposium held in Dresden, Germany. It includes many authors from 17 institutions. Neutrinoless double-beta decay searches play a major role in determining the nature of neutrinos, the existence of a lepton violating process, and the effective Majorana neutrino mass. The MAJORANA Collaboration proposes to assemble an array of HPGe detectors to search for neutrinoless double-beta decay in 76Ge. Our proposed method uses the well-established technique of searching for neutrinoless double-beta decay in high purity Ge-diode radiation detectors that play both roles of source and detector. The technique is augmented with recent improvements in signal processing and detector design, and advances in controlling intrinsic and external backgrounds. Initially, MAJORANA aims to construct a prototype module containing 60 kg of Ge detectors to demonstrate the potential of a future 1-tonne experiment. The design and potential reach of this prototype Demonstrator module will be presented. This paper will also discuss detector optimization and low-background requirements, such as material purity, background rejection, and identification of rare backgrounds required to reach the sensitivity goals of the MAJORANA experiment.

  4. Dose point kernels for beta-emitting radioisotopes

    International Nuclear Information System (INIS)

    Knowledge of the dose point kernel corresponding to a specific radionuclide is required to calculate the spatial dose distribution produced in a homogeneous medium by a distributed source. Dose point kernels for commonly used radionuclides have been calculated previously using as a basis monoenergetic dose point kernels derived by numerical integration of a model transport equation. The treatment neglects fluctuations in energy deposition, an effect which has been later incorporated in dose point kernels calculated using Monte Carlo methods. This work describes new calculations of dose point kernels using the Monte Carlo results as a basis. An analytic representation of the monoenergetic dose point kernels has been developed. This provides a convenient method both for calculating the dose point kernel associated with a given beta spectrum and for incorporating the effect of internal conversion. An algebraic expression for allowed beta spectra has been accomplished through an extension of the Bethe-Bacher approximation, and tested against the exact expression. Simplified expression for first-forbidden shape factors have also been developed. A comparison of the calculated dose point kernel for 32P with experimental data indicates good agreement with a significant improvement over the earlier results in this respect. An analytic representation of the dose point kernel associated with the spectrum of a single beta group has been formulated. 9 references, 16 figures, 3 tables

  5. The GERDA Neutrinoless Double Beta-Decay Experiment

    International Nuclear Information System (INIS)

    Neutrinoless double beta (0νββ)-decay is the key process to gain understanding of the nature of neutrinos. The GErmanium Detector Array (GERDA) is designed to search for 0νββ-decay of the isotope 76Ge. Germanium crystals enriched in 76Ge, acting as source and detector simultaneously, will be submerged directly into an ultra pure cooling medium that also serves as a radiation shield. This concept will allow for a reduction of the background by up to two orders of magnitudes with respect to earlier experiments

  6. Values of the phase space factors for double beta decay

    International Nuclear Information System (INIS)

    We report an up-date list of the experimentally most interesting phase space factors for double beta decay (DBD). The electron/positron wave functions are obtained by solving the Dirac equations with a Coulomb potential derived from a realistic proton density distribution in nucleus and with inclusion of the finite nuclear size (FNS) and electron screening (ES) effects. We build up new numerical routines which allow us a good control of the accuracy of calculations. We found several notable differences as compared with previous results reported in literature and possible sources of these discrepancies are discussed

  7. Search for $\\beta$-delayed protons from $^{11}$Be

    CERN Multimedia

    $\\beta$-delayed proton emission from $^{11}$Be will be a very rare process. It is believed to decay directly into continuum states. This would imply that it will be a sensitive probe of the halo structure of the one-neutron halo nucleus $^{11}$Be. We propose to improve existing (unpublished) limits on this decay mode by two orders of magnitude. Our earlier experience at ISOLDE indicates that the required intensity and purity of the source can be obtained. The branching ratio will be measured by counting the number of $^{10}$Be atoms produced via accelerator mass spectrometry.

  8. Methods of Fabricating Scintillators with Radioisotopes for Beta Battery Applications

    Science.gov (United States)

    Rensing, Noa M.; Squillante, Michael R.; Tieman, Timothy C.; Higgins, William; Shiriwadkar, Urmila

    2013-01-01

    Technology has been developed for a class of self-contained, long-duration power sources called beta batteries, which harvest the energy contained in the radioactive emissions from beta decay isotopes. The new battery is a significant improvement over the conventional phosphor/solar cell concept for converting this energy in three ways. First, the thin phosphor is replaced with a thick scintillator that is transparent to its own emissions. By using a scintillator sufficiently thick to completely stop all the beta particles, efficiency is greatly improved. Second, since the energy of the beta particles is absorbed in the scintillator, the semiconductor photodetector is shielded from radiation damage that presently limits the performance and lifetime of traditional phosphor converters. Finally, instead of a thin film of beta-emitting material, the isotopes are incorporated into the entire volume of the thick scintillator crystal allowing more activity to be included in the converter without self-absorption. There is no chemical difference between radioactive and stable strontium beta emitters such as Sr-90, so the beta emitter can be uniformly distributed throughout a strontium based scintillator crystal. When beta emitter material is applied as a foil or thin film to the surface of a solar cell or even to the surface of a scintillator, much of the radiation escapes due to the geometry, and some is absorbed within the layer itself, leading to inefficient harvesting of the energy. In contrast, if the emitting atoms are incorporated within the scintillator, the geometry allows for the capture and efficient conversion of the energy of particles emitted in any direction. Any gamma rays associated with secondary decays or Bremsstrahlung photons may also be absorbed within the scintillator, and converted to lower energy photons, which will in turn be captured by the photocell or photodiode. Some energy will be lost in this two-stage conversion process (high-energy particle

  9. USE OF GREEN MANURE CROPS AND SUGAR BEET VARIETIES TO CONTROL HETERODERA BETAE.

    Science.gov (United States)

    Raaijmakers, E

    2014-01-01

    Although it is less studied than the white beet cyst nematode (Heterodera schachtii), the yellow beet cyst nematode (H. betae) has been found in many countries in Europe. For example in The Netherlands, France and Spain. H. betae causes yield losses on sandy soils. A high infestation can result in loss of complete plants. In The Netherlands, this nematode is especially found in the south eastern and north eastern part, where it occurs on 18% and 5% of the fields, respectively. From a project of the Dutch Sugar beet Research Institute IRS (SUSY) on factors explaining differences in sugar yield, this nematode was one of the most important factors reducing sugar yields on sandy soils. Until 2008, the only way to control H. betae was by reducing the number of host crops in the crop rotation. Host crops are crops belonging to the families of Cruciferae, Chenopodiaceae, Polygonaceae, Caryophyllaceae and Leguminosea. In order to find more control measures, research was done to investigate the host status of different green manure crops and the resistance and tolerance of different sugar beet varieties to H. betae. White mustard (Sinapis alba) and oil seed radish (Raphanus sativus spp. oleiferus) varieties resistant to H. schachtii were investigated for their resistance against H. betae. A climate room trial and a field trial with white mustard and oil seed radish were conducted in 2007 and 2008, respectively. Results show that H. betae could multiply on susceptible white mustard and susceptible oil seed radish, but not on the H. schachtii resistant varieties. In climate room trials in 2009, 2010 and 2011 and field trials in 2010, 2011 and 2012, the effect of different sugar beet varieties on the multiplication of H. betae and the effect of H. betae on yield at different infestation levels was investigated. Sugar beet varieties with resistance genes to H. schachtii (from Beta procumbens or B. maritima) were selected. Varieties with resistance genes from these sources were

  10. Collective search by mobile robots using alpha-beta coordination

    Energy Technology Data Exchange (ETDEWEB)

    Goldsmith, S.Y.; Robinett, R. III

    1998-04-01

    One important application of mobile robots is searching a geographical region to locate the origin of a specific sensible phenomenon. Mapping mine fields, extraterrestrial and undersea exploration, the location of chemical and biological weapons, and the location of explosive devices are just a few potential applications. Teams of robotic bloodhounds have a simple common goal; to converge on the location of the source phenomenon, confirm its intensity, and to remain aggregated around it until directed to take some other action. In cases where human intervention through teleoperation is not possible, the robot team must be deployed in a territory without supervision, requiring an autonomous decentralized coordination strategy. This paper presents the alpha beta coordination strategy, a family of collective search algorithms that are based on dynamic partitioning of the robotic team into two complementary social roles according to a sensor based status measure. Robots in the alpha role are risk takers, motivated to improve their status by exploring new regions of the search space. Robots in the beta role are motivated to improve but are conservative, and tend to remain aggregated and stationary until the alpha robots have identified better regions of the search space. Roles are determined dynamically by each member of the team based on the status of the individual robot relative to the current state of the collective. Partitioning the robot team into alpha and beta roles results in a balance between exploration and exploitation, and can yield collective energy savings and improved resistance to sensor noise and defectors. Alpha robots waste energy exploring new territory, and are more sensitive to the effects of ambient noise and to defectors reporting inflated status. Beta robots conserve energy by moving in a direct path to regions of confirmed high status.

  11. Ser2 is the autophosphorylation site in the beta subunit from bicistronically expressed human casein kinase-2 and from native rat liver casein kinase-2 beta

    DEFF Research Database (Denmark)

    Boldyreff, B; James, P; Staudenmann, W; Issinger, O G

    1993-01-01

    Human casein kinase-2 (CK-2) subunits alpha and beta were bicistronically expressed in bacteria. The recombinant holoenzyme shared all investigated properties with the native CK-2 from mammalian sources (rat liver, Krebs II mouse ascites tumour cells). Contrary to recombinant human CK-2 produced by...... self-assembly in vitro, the bicistronically expressed beta subunit was autophosphorylated during formation of the holoenzyme in bacteria. Electrospray ionisation mass spectrometry (ESI) revealed Ser2 (second amino acid, first serine) as the only phosphate acceptor site. Kinetic data obtained with...... either the phosphorylated or the unphosphorylated form of CK-2 did not differ significantly, suggesting that the autophosphorylation had no influence on the kinetic parameters Km and Vmax. In parallel, native rat liver CK-2 beta subunit was shown to incorporate 0.1 mol phosphate/mol holoenzyme, which...

  12. Dose assessment of Bremsstrahlung induced by beta isotopes of Uranium-238 series in human tissues

    International Nuclear Information System (INIS)

    In the natural Uranium-238 decay series, pure beta isotopes such as 234Th, 234Pa, 214Pb, 214Bi, 210Pb and 210Bi are released. These beta isotopes having maximum beta energies and it induces the Bremsstrahlung radiation. The Bremsstrahlung component of these beta isotopes has been traditionally ignored in dosimetry calculations. This may be due to a lack of available methods for including this component in the calculations or to the belief that the contribution of this component is negligible compared to that of other emissions. The resulting hazard of Bremsstrahlung radiation may therefore be some of concern, at least theoretically, and should be systematically evaluated. In the present investigation, it has been estimated that the Bremsstrahlung dose of beta isotopes of Uranium-238 series such as 234Th, 234Pa, 214Pb, 214Bi, 210Pb and 210Bi in various body organs (Adrenals, Brain, Breasts, Gallbladder Wall, LLI Wall, Small Intestine, Stomach, ULI Wall, Heart Wall, Kidneys, Liver, Lungs, Muscle, Ovaries, Pancreas, Red Marrow, Bone Surfaces, Skin, Spleen, Testes, Thymus, Thyroid, Urine Bladder Wall, Uterus, Fetus, Placenta and Total Body). We have considered bone and muscle is target organs. These estimated values shows that the Bremsstrahlung radiation absorbed dose contribution from an organ to itself is very small compared to that from the beta source, but contribution to other organs is not always negligible. Hence the component of Bremsstrahlung dose to total dose should be considered in the environmental radioactivity dose calculations. (author)

  13. Measurement of gross alpha and beta in air filter samples by using liquid scintillation counter

    International Nuclear Information System (INIS)

    The determination of gross alpha and gross beta in particulate air filter samples was carried out by alpha, beta discrimination method using Liquid Scintillation Analyzer by setting the PSA value at 55 for 5 ml 0.1 HCl plus 15 ml of Ultima Gold AB cocktail by using 241Am and 90Sr/90Y sources. The standardized method was compared with the gross alpha and gross beta activity determined by conventional method of direct counting with end window G.M. counter and ZnS (Ag). The minimum detectable activity of LSA method was found to be 9.3 mBq and 17.7 mBq for gross alpha and gross beta respectively for 6000 sec compared to the conventional method of 9.8 mBq and 189 mBq respectively at the same counting time. The result of analysis by both method indicate that the alpha, beta discrimination set up of LSA method is highly effective in the determination of low level alpha, beta activity in air filter samples. (author)

  14. Inhibitory effect of different product analogues on {beta}-alanine synthase: A thermodynamic and fluorescence analysis

    Energy Technology Data Exchange (ETDEWEB)

    Andujar-Sanchez, Montserrat; Martinez-Gomez, Ana Isabel; Martinez-Rodriguez, Sergio; Clemente-Jimenez, Josefa Maria; Heras-Vazquez, Francisco Javier Las; Rodriguez-Vico, Felipe [Departamento de Quimica Fisica, Bioquimica y Quimica Inorganica, Facultad de Ciencias Experimentales, Universidad de Almeria, Carretera de Sacramento s/n, La Canada de San Urbano, Almeria 04120 (Spain); Jara-Perez, Vicente [Departamento de Quimica Fisica, Bioquimica y Quimica Inorganica, Facultad de Ciencias Experimentales, Universidad de Almeria, Carretera de Sacramento s/n, La Canada de San Urbano, Almeria 04120 (Spain)], E-mail: vjara@ual.es

    2009-02-15

    The enzyme N-carbamoyl-{beta}-alanine amidohydrolase catalyse the hydrolysis of N-carbamoyl-{beta}-alanine or N-carbamoyl-{beta}-aminoisobutyric acid to {beta}-alanine or 3-aminoisobutyric acid, under the release of carbon-dioxide and ammonia. This work studies the inhibition of N-carbamoyl-{beta}-alanine amidohydrolase from Agrobacterium tumefaciens C58 (At{beta}car) by different carboxylic acid compounds that differ in number of carbons, and position and size of ramification, while the binding thermodynamics of the inhibitors are studied by isothermal titration calorimetry (ITC) and fluorescence. From the binding constants and inhibition studies, we conclude that propionate is the most efficient inhibitor among those tested. Substitution of the linear alkyl acids in positions 2 and 3 resulted in a drastic decrease of the affinity. The thermodynamic parameters show that a conformational change is triggered upon ligand binding. Binding enthalpy {delta}H{sub b} is negative in all cases for all ligands, and thus, Van der Waals interactions and hydrogen bonding are most probably the major sources for this term. The process is entropically favoured at all temperatures and pH studied, most probably due to the liberation of water molecules accompanying the conformational change of the enzyme.

  15. Synthesis of zeolite beta with pretreated rice husk silica and its transformation to ZSM-12

    International Nuclear Information System (INIS)

    Silica with 98% purity was prepared from rice husk by acid leaching and used as a silica source for the syntheses of zeolite beta (Beta) under hydrothermal conditions with gel Si/Al ratios of 8, 13, 15, 20, 50, 100, 150, and 200. Based on powder X-ray diffraction patterns, samples with gel Si/Al ratios of 8-20 contained only the pure phase of Beta and the highest relative crystallinity was observed in the Beta with gel Si/Al ratio of 13. This sample was further characterized by scanning electron microscopy, particle size analyzer and N2 adsorption analysis. The Beta particles were sphere shaped with the average particle size of 1.5 μm and a surface area of 670 m2 g-1. The samples with gel Si/Al ratios ranging from 50 to 200 showed mixed phases of Beta and ZSM-12, and the latter phase was more dominant as the Si/Al ratio increased.

  16. Role of Ink4a/Arf Locus in Beta Cell Mass Expansion under Physiological and Pathological Conditions

    Directory of Open Access Journals (Sweden)

    Elisabet Salas

    2014-01-01

    Full Text Available The ARF/INK4A (Cdkn2a locus includes the linked tumour suppressor genes p16INK4a and p14ARF (p19ARF in mice that trigger the antiproliferative activities of both RB and p53. With beta cell self-replication being the primary source for new beta cell generation in adult animals, the network by which beta cell replication could be increased to enhance beta cell mass and function is one of the approaches in diabetes research. In this review, we show a general view of the regulation points at transcriptional and posttranslational levels of Cdkn2a locus. We describe the molecular pathways and functions of Cdkn2a in beta cell cycle regulation. Given that aging reveals increased p16Ink4a levels in the pancreas that inhibit the proliferation of beta cells and decrease their ability to respond to injury, we show the state of the art about the role of this locus in beta cell senescence and diabetes development. Additionally, we focus on two approaches in beta cell regeneration strategies that rely on Cdkn2a locus negative regulation: long noncoding RNAs and betatrophin.

  17. Role of Ink4a/Arf Locus in Beta Cell Mass Expansion under Physiological and Pathological Conditions

    Science.gov (United States)

    Salas, Elisabet; Rabhi, Nabil; Froguel, Philippe; Annicotte, Jean-Sébastien

    2014-01-01

    The ARF/INK4A (Cdkn2a) locus includes the linked tumour suppressor genes p16INK4a and p14ARF (p19ARF in mice) that trigger the antiproliferative activities of both RB and p53. With beta cell self-replication being the primary source for new beta cell generation in adult animals, the network by which beta cell replication could be increased to enhance beta cell mass and function is one of the approaches in diabetes research. In this review, we show a general view of the regulation points at transcriptional and posttranslational levels of Cdkn2a locus. We describe the molecular pathways and functions of Cdkn2a in beta cell cycle regulation. Given that aging reveals increased p16Ink4a levels in the pancreas that inhibit the proliferation of beta cells and decrease their ability to respond to injury, we show the state of the art about the role of this locus in beta cell senescence and diabetes development. Additionally, we focus on two approaches in beta cell regeneration strategies that rely on Cdkn2a locus negative regulation: long noncoding RNAs and betatrophin. PMID:24672805

  18. Optical Spectroscopy of Four Young Radio Sources

    CERN Document Server

    Fan, Xu-Liang; Hu, Chen; Wang, Jian-Guo

    2016-01-01

    We report the optical spectroscopy of four young radio sources which are observed with the Lijiang 2.4m telescope. The Eddington ratios of these sources are similar with those of narrow-line Seyfert 1 galaxies (NLS1s). Their Fe {\\sc ii} emission is strong while [O {\\sc iii}] strength is weak. These results confirm the NLS1 features of young radio sources, except that the width of broad H$\\beta$ of young radio sources is larger than that of NLS1s. We thus suggest that the young radio sources are the high black hole mass counterparts of steep-spectrum radio-loud NLS1s. In addition, the broad H$\\beta$ component of \\astrobj{4C 12.50} is the blue wing of the narrow component, but not from the broad line region.

  19. Conformation, molecular packing and field effect mobility of regioregular beta,beta'-dihexylsexithiophiophene

    DEFF Research Database (Denmark)

    Kiriy, N.; Kiriy, A.; Bocharova, V.;

    2004-01-01

    (SEM), atomic force microscopy (AFM), and X-ray techniques. Absorption spectra of a beta,beta'-DH6T spin-cast film indicate the planar conformation of the aromatic backbone. SEM and AFM reveal the formation of an ordered lamellar phase. As a single-crystal X-ray study shows, beta,beta'-DH6T exhibits......Improved synthesis, charge carrier mobility, conformation, crystalline structure, and molecular packing of the regiochemically pure 4',3""-dihexyl-2,2';5',2";5",2 "';5"',2"";5"",2""'-sexithiophene (beta,beta'-DH6T) are reported. The sum of charge carrier mobilities of beta,beta'-DH6T measured...... by the pulse-radiolysis time-resolved microwave conductivity (PR-TRMC) technique was found to be Sigmamu(min) = 3.9 x 10(-3) cm(2) V-1 s(-1), which is comparable with the PR-TRMC mobility found for alpha,omega-DH6T. The field-effect mobility (FEM) of beta,beta'-DH6T was found to be on the order of 10(-5) cm(2...

  20. Ellagic acid promotes A{beta}42 fibrillization and inhibits A{beta}42-induced neurotoxicity

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Ying [Department of Histology and Embryology, College of Basic Medical Science, China Medical University, Shenyang 110001 (China); Tsinghua University School of Medicine, Haidian District, Beijing 100084 (China); Yang, Shi-gao; Du, Xue-ting; Zhang, Xi; Sun, Xiao-xia; Zhao, Min [Tsinghua University School of Medicine, Haidian District, Beijing 100084 (China); Sun, Gui-yuan, E-mail: sungy2004@sohu.com [Department of Histology and Embryology, College of Basic Medical Science, China Medical University, Shenyang 110001 (China); Liu, Rui-tian, E-mail: rtliu@tsinghua.edu.cn [Tsinghua University School of Medicine, Haidian District, Beijing 100084 (China)

    2009-12-25

    Smaller, soluble oligomers of {beta}-amyloid (A{beta}) play a critical role in the pathogenesis of Alzheimer's disease (AD). Selective inhibition of A{beta} oligomer formation provides an optimum target for AD therapy. Some polyphenols have potent anti-amyloidogenic activities and protect against A{beta} neurotoxicity. Here, we tested the effects of ellagic acid (EA), a polyphenolic compound, on A{beta}42 aggregation and neurotoxicity in vitro. EA promoted A{beta} fibril formation and significant oligomer loss, contrary to previous results that polyphenols inhibited A{beta} aggregation. The results of transmission electron microscopy (TEM) and Western blot displayed more fibrils in A{beta}42 samples co-incubated with EA in earlier phases of aggregation. Consistent with the hypothesis that plaque formation may represent a protective mechanism in which the body sequesters toxic A{beta} aggregates to render them harmless, our MTT results showed that EA could significantly reduce A{beta}42-induced neurotoxicity toward SH-SY5Y cells. Taken together, our results suggest that EA, an active ingredient in many fruits and nuts, may have therapeutic potential in AD.

  1. A study on the beta voltaic micro-nuclear battery based on the planar technology silicon detector

    International Nuclear Information System (INIS)

    It describes briefly the beta voltaic micro-nuclear battery based on the planar technology silicon detector and radioisotope. Different sensitive area of silicon detectors are used to cooperate with 63Ni source to buildup of beta voltaic micro-nuclear batteries. The experimental data show that the larger sensitive area the silicon detector has, the higher open circuit voltage it produces, and the open circuit voltage of single cell has reached an excellent result from 0.15 V to 0.30 V. It is possible to get high output power by series or parallel connecting the beta voltaic micro-nuclear batteries. (authors)

  2. Total synthesis of human beta-lipotropin.

    OpenAIRE

    Blake, J; Li, C. H.

    1983-01-01

    The total synthesis of human beta-lipotropin has been accomplished by the new segment-coupling method in aqueous solution. The peptides Ac-Arg-beta-lipotropin-(61-89) (I) and [GlyS60]-beta-lipotropin-(1-60) (II) were synthesized by the solid-phase method. Reaction of peptide I with citraconic anhydride followed by brief digestion with trypsin to remove the acetylarginyl group, gave Ia. Reaction of peptide II with citraconic anhydride gave the citraconyl peptide IIa. Ia and IIa were coupled to...

  3. Rotational beta expansion: Ergodicity and Soficness

    OpenAIRE

    Akiyama, Shigeki; Caalim, Jonathan

    2015-01-01

    We study a family of piecewise expanding maps on the plane, generated by composition of a rotation and an expansive similitude of expansion constant $\\beta$. We give two constants $B_1$ and $B_2$ depending only on the fundamental domain that if $\\beta>B_1$ then the expanding map has a unique absolutely continuous invariant probability measure, and if $\\beta>B_2$ then it is equivalent to $2$-dimensional Lebesgue measure. Restricting to a rotation generated by $q$-th root of unity $\\zeta$ with ...

  4. Falsifying Baryogenesis with Neutrinoless Double Beta Decay

    CERN Document Server

    Graf, Lukas

    2016-01-01

    We discuss the relation between lepton number violation at high and low energies, particularly, the constraints on baryogenesis models, which would be implied by an observation of neutrinoless double beta decay. The primordial baryon asymmetry can be washed out by effective lepton number violating operators triggering neutrinoless double beta decay in combination with sphaleron processes. A generic conclusion is that popular models of baryogenesis are excluded if a non-standard mechanism of neutrinoless double beta decay, i.e., other than the standard light neutrino exchange, is observed. Apart from the effective field approach, we also outline the possible extension of our arguments to a general UV-completed model.

  5. Beta-alanine synthesis in Escherichia coli.

    OpenAIRE

    Cronan, J. E.

    1980-01-01

    The enzyme, aspartate 1-decarboxylase (L-aspartate 1-carboxy-lyase; EC 4.1.1.15), that catalyzes the reaction aspartate leads to beta-alanine + CO2 was found in extracts of Escherichia coli. panD mutants of E. coli are defective in beta-alanine biosynthesis and lack aspartate 1-decarboxylase. Therefore, the enzyme functions in the biosynthesis of the beta-alanine moiety of pantothenate. The genetic lesion in these mutants is closely linked to the other pantothenate (pan) loci of E. coli K-12.

  6. Review of modern double beta decay experiments

    Science.gov (United States)

    Barabash, A. S.

    2015-10-01

    The review of modern experiments on search and studying of double beta decay processes is done. Results of the most sensitive current experiments are discussed. The main attention is paid to EXO-200, KamLAND-Zen, GERDA-I and CUORE-0 experiments. Modern values of T1/2(2ν) and best present limits on neutrinoless double beta decay and double beta decay with Majoron emission are presented. Conservative limits on effective mass of a Majorana neutrino ( at the level of ˜ 0.01-0.1 eV are discussed.

  7. Alpha Beta Monitoring System Based on a Pair of Simultaneous Multi Wire Proportional Counters

    International Nuclear Information System (INIS)

    A new approach for a simultaneous alpha beta contamination monitoring system is presented. In nuclear environments or laboratories working with open radioactive sources there exists a risk of contamination. In order to avoid external contamination hazards, hand & foot alpha beta monitoring systems are needed. Usually, monitoring systems are based on large area Multi Wire Proportional Counters (MWPC).Generally, in the MWPC detectors the filling gas is supplied by a continuous gas supply system. The filling gas should not exhibit appreciable electron attachment coefficient. Typically, a noble gas such as Argon Methane, 90%Ar+10%CH4 is in use. This method of measurement is effective, yet it requires expensive maintenance costs due to gas flow control and periodical replacements. Several hand held commercial detectors such as Rotem Ind. PA-100, are based on free air flow alpha MWPC. Due to the energy released from the alpha particles in the filling gas a large number of ion pairs are formed. Despite the electron attachment coefficient of free air, a measurable pulse is obtained. Contrary to alpha sources, beta emitters deposit only a small part of their energy. In order to obtain a measurable pulse from beta interactions, oxygen free gas is required. Gas sealed detectors which are appropriate for beta measurements, require a relative thick entrance window in order to avoid gas leakage. Thick windows absorb alpha particles so that they are not appropriate for alpha measurement. The presented approach combines a pair of simultaneous MWPC assembled in a ôpancakeö type configuration; the sealed gas beta counter is located behind a free air alpha detector. This approach enables simultaneous alpha-beta measurement without needing continuous gas supply

  8. Evaluation of transmission factor in beta radiotherapy by MCNP-4A code

    International Nuclear Information System (INIS)

    Beta radiotherapy has been established as an alternative treatment of ocular diseases, including pterygium, keratitis, melanoma, carcinoma and cornea vascularisation. However this radiation can cause pernicious secondary effects such as eye lens cataract development. Therefore, it is of great interest to observe the doses limit in the eye lens, which must not compromise the therapeutic success of the cornea treatment. To achieve this objective, computational Monte Carlo techniques have been used in order to formulate a human eye representative geometrical model and to analyze dosimetry parameters under beta rays emission. A well-known radioactive source was utilized, 90Sr/90Y, and also a 147Pm source. Several evaluations have been made for different source-cornea length, and the cornea doses/eye lens doses ratio results were obtained and compared. Doses variation due to the insertion of stainless steel absorbers was also evaluated for the 90Sr/90Y source. (author)

  9. Beta cell count instead of beta cell mass to assess and localize growth in beta cell population following pancreatic duct ligation in mice.

    Directory of Open Access Journals (Sweden)

    Marie Chintinne

    Full Text Available BACKGROUND: Pancreatic-tail duct ligation (PDL in adult rodents has been reported to induce beta cell generation and increase beta cell mass but increases in beta cell number have not been demonstrated. This study examines whether PDL increases beta cell number and whether this is caused by neogenesis of small clusters and/or their growth to larger aggregates. METHODOLOGY: Total beta cell number and its distribution over small (100 µm clusters was determined in pancreatic tails of 10-week-old mice, 2 weeks after PDL or sham. PRINCIPAL FINDINGS: PDL increased total beta cell mass but not total beta cell number. It induced neogenesis of small beta cell clusters (2.2-fold higher number which contained a higher percent proliferating beta cells (1.9% Ki67+cells than sham tails (<0.2%; their higher beta cell number represented <5% of total beta cell number and was associated with a similar increase in alpha cell number. It is unknown whether the regenerative process is causally related to the inflammatory infiltration in PDL-tails. Human pancreases with inflammatory infiltration also exhibited activation of proliferation in small beta cell clusters. CONCLUSIONS/SIGNIFICANCE: The PDL model illustrates the advantage of direct beta cell counts over beta cell mass measurements when assessing and localizing beta cell regeneration in the pancreas. It demonstrates the ability of the adult mouse pancreas for neogenesis of small beta cell clusters with activated beta cell proliferation. Further studies should investigate conditions under which neoformed small beta cell clusters grow to larger aggregates and hence to higher total beta cell numbers.

  10. Energetic, Structural, and Antimicrobial Analyses of [beta]-Lactam Side Chain Recognition by [beta]-Lactamases

    Energy Technology Data Exchange (ETDEWEB)

    Caselli, E.; Powers, R.A.; Blaszczak, L.C.; Wu, C.Y.E.; Prati, F.; Shoichet, B.K. (NWU)

    2010-03-05

    Penicillins and cephalosporins are among the most widely used and successful antibiotics. The emergence of resistance to these {beta}-lactams, most often through bacterial expression of {beta}-lactamases, threatens public health. To understand how {beta}-lactamases recognize their substrates, it would be helpful to know their binding energies. Unfortunately, these have been difficult to measure because {beta}-lactams form covalent adducts with {beta}-lactamases. This has complicated functional analyses and inhibitor design. To investigate the contribution to interaction energy of the key amide (R1) side chain of {beta}-lactam antibiotics, eight acylglycineboronic acids that bear the side chains of characteristic penicillins and cephalosporins, as well as four other analogs, were synthesized. These transition-state analogs form reversible adducts with serine {beta}-lactamases. Therefore, binding energies can be calculated directly from K{sub i} values. The K{sub i} values measured span four orders of magnitude against the Group I {beta}-lactamase AmpC and three orders of magnitude against the Group II {beta}-lactamase TEM-1. The acylglycineboronic acids have K{sub i} values as low as 20 nM against AmpC and as low as 390 nM against TEM-1. The inhibitors showed little activity against serine proteases, such as chymotrypsin. R1 side chains characteristic of {beta}-lactam inhibitors did not have better affinity for AmpC than did side chains characteristic of {beta}-lactam substrates. Two of the inhibitors reversed the resistance of pathogenic bacteria to {beta}-lactams in cell culture. Structures of two inhibitors in their complexes with AmpC were determined by X-ray crystallography to 1.90 {angstrom} and 1.75 {angstrom} resolution; these structures suggest interactions that are important to the affinity of the inhibitors. Acylglycineboronic acids allow us to begin to dissect interaction energies between {beta}-lactam side chains and {beta}-lactamases. Surprisingly

  11. Bound beta-decay: BOB

    International Nuclear Information System (INIS)

    For many years exotic decay modes of the neutron have been investigated as possible doorways to the exploration of new physics. The bound beta-decay (BOB) of the neutron into a hydrogen atom and an anti-neutrino offers a very elegant method to study neutrino helicities. However, this rare decay has not yet been observed for the free neutron, owing to the challenge of measuring a decay involving only electrically neutral particles and with an estimated branching ratio of only a few 106 of the three-body decay mode. During the past few years scientists from the TUM E18 Group have developed a novel experimental scheme which addresses all necessary problems associated with the observation of this two-body neutron decay in a very coherent way. The BOB experiment shall be installed at a tangential beam tube of a powerful research reactor such as the SR6 at the FRMII in Garching or H6-H7 beam tube at ILL. This talk will provide insights and ideas on how such an experiment is to be performed.

  12. Dopamine beta-hydroxylase deficiency

    Directory of Open Access Journals (Sweden)

    Senard Jean-Michel

    2006-03-01

    Full Text Available Abstract Dopamine beta-hydroxylase (DβH deficiency is a very rare form of primary autonomic failure characterized by a complete absence of noradrenaline and adrenaline in plasma together with increased dopamine plasma levels. The prevalence of DβH deficiency is unknown. Only a limited number of cases with this disease have been reported. DβH deficiency is mainly characterized by cardiovascular disorders and severe orthostatic hypotension. First symptoms often start during a complicated perinatal period with hypotension, muscle hypotonia, hypothermia and hypoglycemia. Children with DβH deficiency exhibit reduced ability to exercise because of blood pressure inadaptation with exertion and syncope. Symptoms usually worsen progressively during late adolescence and early adulthood with severe orthostatic hypotension, eyelid ptosis, nasal stuffiness and sexual disorders. Limitation in standing tolerance, limited ability to exercise and traumatic morbidity related to falls and syncope may represent later evolution. The syndrome is caused by heterogeneous molecular alterations of the DBH gene and is inherited in an autosomal recessive manner. Restoration of plasma noradrenaline to the normal range can be achieved by therapy with the synthetic precursor of noradrenaline, L-threo-dihydroxyphenylserine (DOPS. Oral administration of 100 to 500 mg DOPS, twice or three times daily, increases blood pressure and reverses the orthostatic intolerance.

  13. Improved aqueous solubility of crystalline astaxanthin (3,3'-dihydroxy-beta, beta-carotene-4,4'-dione) by Captisol (sulfobutyl ether beta-cyclodextrin).

    Science.gov (United States)

    Lockwood, Samuel F; O'Malley, Sean; Mosher, Gerold L

    2003-04-01

    Carotenoids are the most widely distributed natural pigments, with over 600 individual compounds identified and characterized from natural sources. A few are commercially important molecules, having found utility as additions to animal feed in the aquaculture, poultry, and swine feed industries. The majority are lipophilic molecules with near zero inherent aqueous solubility. Many different methods have been developed to make the carotenoids "water dispersible," as true water solubility has not been described. Astaxanthin (3,3'-dihydroxy-beta, beta-carotene-4,4'-dione) is a commercially important oxygenated carotenoid that has gained wide acceptance as a feed additive in the $50 billion salmon and trout aquaculture industry. Recently, interest in the human health applications of astaxanthin has increased, with astaxanthin receiving approval as a dietary supplement in several countries, including the United States. Moving astaxanthin into a pharmaceutical application will require a chemical delivery system that overcomes the problems with parenteral administration of a highly lipophilic, low molecular weight compound. In the current study, the ability of sulfobutyl ether beta-cyclodextrin (sodium), as the Captisol(R) brand, to increase the aqueous water solubility of crystalline astaxanthin was evaluated. Complexation of crystalline astaxanthin with Captisol increased the apparent water solubility of crystalline astaxanthin approximately 71-fold, to a concentration in the 2 microg/mL range. It is unlikely that this increase in solubility will result in a pharmaceutically acceptable chemical delivery system for humans. However, the increased aqueous solubility of crystalline astaxanthin to the range achieved in the current study will likely find utility in the introduction of crystalline astaxanthin into mammalian cell culture systems that have previously been dependent upon liposomes, or toxic organic solvents, for the introduction of carotenoids into aqueous

  14. Measurement of the energy dependent beta asymmetry in the decay of 8Li

    International Nuclear Information System (INIS)

    Progress is reported on a new measurement of the beta decay asymmetry in 8Li. Polarized 8Li is produced via the reaction 7Li(d,p)8Li using vector polarized deuterons from a crossed beam polarized source. Plastic scintillation electron counters are used to measure asymmetry, tensor polarization correlation and to monitor beam current. Results are graphed and systematic error sources are discussed. 4 refs

  15. Pressure phase lines and enthalpies for the. cap alpha. -. beta. and. beta. -liquid transitions in beryllium

    Energy Technology Data Exchange (ETDEWEB)

    Abey, A.

    1984-10-31

    The effect of hydrostatic pressure on the ..cap alpha..-..beta.. and ..beta..-liquid transition temperatures in Be was measured in a gas pressure system. Differential thermal analysis was used in the pressure range from 0.1 MPa to 0.7 GPa. For the ..cap alpha..-..beta.. transition, dT/dP = 43 +- 7 K/GPa; for the ..beta..-liquid transition, dT/dP = 35 +- 7 K/GPa. Although it is possible that large systematic errors may arise from experimental procedures, our results are seriously at odds with those of other investigators. Transition enthalpies for the ..cap alpha..-..beta.. and ..beta..-liquid transitions were 1.9 +- 0.2 and 2.2 +- 0.2 kcal/g.m., respectively, at a pressure of 0.1 MPa.

  16. A comparison of enzymatic phosphorylation and phosphatidylation of beta-L- and beta-D-nucleosides.

    Science.gov (United States)

    Birichevskaya, Larisa L; Kvach, Sergei V; Sivets, Grigorii G; Kalinichenko, Elena N; Zinchenko, Anatoly I; Mikhailopulo, Igor A

    2007-04-01

    Enzymatic 5'-monophosphorylation and 5'-phosphatidylation of a number of beta-L- and beta-D-nucleosides was investigated. The first reaction, catalyzed by nucleoside phosphotransferase (NPT) from Erwinia herbicola, consisted of the transfer of the phosphate residue from p-nitrophenylphosphate (p-NPP) to the 5'-hydroxyl group of nucleoside; the second was the phospholipase D (PLD)-catalyzed transphosphatidylation of L-alpha-lecithin with a series of beta-L- and beta-D-nucleosides as the phosphatidyl acceptor resulted in the formation of the respective phospholipid-nucleoside conjugates. Some beta-L-nucleosides displayed similar or even higher substrate activity compared to the beta-D-enantiomers. PMID:17206374

  17. Systematic Risk on Istanbul Stock Exchange: Traditional Beta Coefficient Versus Downside Beta Coefficient

    Directory of Open Access Journals (Sweden)

    Gülfen TUNA

    2013-03-01

    Full Text Available The aim of this study is to test the validity of Downside Capital Asset Pricing Model (D-CAPM on the ISE. At the same time, the explanatory power of CAPM's traditional beta and D-CAPM's downside beta on the changes in the average return values are examined comparatively. In this context, the monthly data for seventy three stocks that are continuously traded on the ISE for the period 1991-2009 is used. Regression analysis is applied in this study. The research results have shown that D-CAPM is valid on the ISE. In addition, it is obtained that the power of downside beta coefficient is higher than traditional beta coefficient on explaining the return changes. Therefore, it can be said that the downside beta is superior to traditional beta in the ISE for chosen period.

  18. Review of modern double beta decay experiments

    International Nuclear Information System (INIS)

    The review of modern experiments on search and studying of double beta decay processes is done. Results of the most sensitive current experiments are discussed. The main attention is paid to EXO-200, KamLAND-Zen, GERDA-I and CUORE-0 experiments. Modern values of T1/2(2ν) and best present limits on neutrinoless double beta decay and double beta decay with Majoron emission are presented. Conservative limits on effective mass of a Majorana neutrino (〈mν〉 < 0.46 eV) and a coupling constant of Majoron to neutrino (〈gee〉 < 1.3 · 10−5) are obtained. Prospects of search for neutrinoless double beta decay in new experiments with sensitivity to 〈mν〉 at the level of ∼ 0.01-0.1 eV are discussed

  19. Neutrino potential for neutrinoless double beta decay

    CERN Document Server

    Iwata, Yoritaka

    2016-01-01

    Neutrino potential for neutrinoless double beta decay is studied with focusing on its statistical property. The statistics provide a gross view of understanding amplitude of constitutional components of the nuclear matrix element.

  20. Literature in Focus Beta Beams: Neutrino Beams

    CERN Document Server

    2009-01-01

    By Mats Lindroos (CERN) and Mauro Mezzetto (INFN Padova, Italy) Imperial Press, 2009 The beta-beam concept for the generation of electron neutrino beams was first proposed by Piero Zucchelli in 2002. The idea created quite a stir, challenging the idea that intense neutrino beams only could be produced from the decay of pions or muons in classical neutrino beams facilities or in future neutrino factories. The concept initially struggled to make an impact but the hard work by many machine physicists, phenomenologists and theoreticians over the last five years has won the beta-beam a well-earned position as one of the frontrunners for a possible future world laboratory for high intensity neutrino oscillation physics. This is the first complete monograph on the beta-beam concept. The book describes both technical aspects and experimental aspects of the beta-beam, providing students and scientists with an insight into the possibilities o...

  1. Genetics Home Reference: beta-mannosidosis

    Science.gov (United States)

    ... depression, or have behavioral problems such as hyperactivity, impulsivity or aggression. People with beta-mannosidosis may experience ... and management of various health conditions: Diagnostic Tests Drug Therapy Surgery and Rehabilitation Genetic Counseling Palliative Care ...

  2. Review of modern double beta decay experiments

    Energy Technology Data Exchange (ETDEWEB)

    Barabash, A. S., E-mail: barabash@itep.ru [Institute of Theoretical and Experimental Physics (NRC ”Kurchatov Institute”), B. Cheremushkinskaya 25, Moscow (Russian Federation)

    2015-10-28

    The review of modern experiments on search and studying of double beta decay processes is done. Results of the most sensitive current experiments are discussed. The main attention is paid to EXO-200, KamLAND-Zen, GERDA-I and CUORE-0 experiments. Modern values of T{sub 1/2}(2ν) and best present limits on neutrinoless double beta decay and double beta decay with Majoron emission are presented. Conservative limits on effective mass of a Majorana neutrino (〈m{sub ν}〉 < 0.46 eV) and a coupling constant of Majoron to neutrino (〈g{sub ee}〉 < 1.3 · 10{sup −5}) are obtained. Prospects of search for neutrinoless double beta decay in new experiments with sensitivity to 〈m{sub ν}〉 at the level of ∼ 0.01-0.1 eV are discussed.

  3. Beta decay of highly charged ions

    International Nuclear Information System (INIS)

    Ion storage rings and ion traps provide the very first opportunity to address nuclear beta decay under conditions prevailing in hot stellar plasmas during nucleosynthesis, i.e. at high atomic charge states. Experiments are summarized that were performed in this field during the last decade at the ion storage-cooler ring ESR in Darmstadt. Special emphasis is given to the first observation of bound-state beta decay, where the created electron remains bound in an inner orbital of the daughter atom. The impact of this specific 'stellar' decay mode for s-process nucleosynthesis as well as for nuclear 'eon clocks' is outlined. Finally, a new technique, single-ion decay spectroscopy, is presented, where one observes two-body beta decay characteristics (i.e. orbital electron capture or bound-state beta decay) of highly charged, single ions for well-defined nuclear and atomic quantum states of both the mother - and the daughter - ion.

  4. High-Beta and very high-beta optics studies for the LHC

    CERN Document Server

    Faus-Golfe, A

    2004-01-01

    New high-beta and very high-beta optics have been sought in order to find the best possible configuration for measuring elastic scattering at the LHC. They are based on the nominal powering scheme of the low-beta triplet. A list of the various possible solutions is given in this report. A particularly interesting solution has been found for a case where the phase advance in both planes at the detector are clore to pi/2.

  5. Adenoviruses Expressing PDX-1, BETA2/NeuroD and MafA Induces the Transdifferentiation of Porcine Neonatal Pancreas Cell Clusters and Adult Pig Pancreatic Cells into Beta-Cells

    Directory of Open Access Journals (Sweden)

    Young-Hye You

    2011-04-01

    Full Text Available BackgroundA limitation in the number of insulin-producing pancreatic beta-cells is a special feature of diabetes. The identification of alternative sources for the induction of insulin-producing surrogate beta-cells is a matter of profound importance. PDX-1/VP16, BETA2/NeuroD, and MafA overexpression have been shown to influence the differentiation and proliferation of pancreatic stem cells. However, few studies have been conducted using adult animal pancreatic stem cells.MethodsAdult pig pancreatic cells were prepared from the non-endocrine fraction of adult pig pancreata. Porcine neonatal pancreas cell clusters (NPCCs were prepared from neonatal pigs aged 1-2 days. The dispersed pancreatic cells were infected with PDX-1/VP16, BETA2/NeuroD, and MafA adenoviruses. After infection, these cells were transplanted under the kidney capsules of normoglycemic nude mice.ResultsThe adenovirus-mediated overexpression of PDX-1, BETA2/NeuroD and MafA induced insulin gene expression in NPCCs, but not in adult pig pancreatic cells. Immunocytochemistry revealed that the number of insulin-positive cells in NPCCs and adult pig pancreatic cells was approximately 2.6- and 1.1-fold greater than those in the green fluorescent protein control group, respectively. At four weeks after transplantation, the relative volume of insulin-positive cells in the grafts increased in the NPCCs, but not in the adult porcine pancreatic cells.ConclusionThese data indicate that PDX-1, BETA2/NeuroD, and MafA facilitate the beta-cell differentiation of NPCCs, but not adult pig pancreatic cells. Therefore PDX-1, BETA2/NeuroD, and MafA-induced NPCCs can be considered good sources for the induction of pancreatic beta-cells, and may also have some utility in the treatment of diabetes.

  6. Genetic counselling in the beta-thalassaemias

    OpenAIRE

    Ioannides, Adonis S.

    2013-01-01

    The beta-thalassaemias are very important genetic disorders of haemoglobin synthesis and are amongst the commonest monogenic disorders. In view of the severity of beta-thalassaemia major, a number of screening programmes have been developed aimed at reducing the number of individuals born with the condition. Genetic counsellingplays a vital role in this process supporting the successful implementation of screening and delineating available options to at risk individuals. This review assesses ...

  7. Searches for neutrinoless double beta decay

    Science.gov (United States)

    Schwingenheuer, Bernhard

    2012-07-01

    Neutrinoless double beta decay is a lepton number violating process whose observation would also establish that neutrinos are their own anti-particles. There are many experimental efforts with a variety of techniques. Some (EXO, Kamland-Zen, GERDA phase I and CANDLES) started take data in 2011 and EXO has reported the first measurement of the half life for the double beta decay with two neutrinos of 136Xe. The sensitivities of the different proposals are reviewed.

  8. Searches for neutrinoless double beta decay

    CERN Document Server

    Schwingenheuer, B

    2012-01-01

    Neutrinoless double beta decay is a lepton number violating process whose observation would also establish that neutrinos are their own anti-particles. There are many experimental efforts with a variety of techniques. Some (EXO, Kamland-Zen, GERDA phase I and CANDLES) started take data in 2011 and EXO has reported the first measurement of the half life for the double beta decay with two neutrinos of $^{136}$Xe. The sensitivities of the different proposals are reviewed.

  9. Conditionally parametric fits for CAPM betas

    OpenAIRE

    Abberger, Klaus

    2004-01-01

    The CAPM model assumes stock returns to be a linear function of the market return. However, there is considerable evidence that the beta stability assumption commonly used when estimating the model is invalid. Nonparametric regression methods are used to examine the stability of beta coefficients in German stock returns. Since local polynomial regression is used for estimation, known methods for testing the stability and for bandwidth choice can be used. For some returns the test indicates ti...

  10. Progress report on the Los Alamos tritium beta decay experiment

    International Nuclear Information System (INIS)

    Measurements near the endpoint of the tritium beta-decay spectrum using a gaseous molecular tritium source yield an essentially model-independent upper limit of 27 eV on the /ovr ν//sub e/ mass at the 95% confidence level. Since demonstrating from this initial measurement the successful operation of a gaseous source based system, most of our effort has been concentrated towards the upgrade and optimization of the experimental apparatus. The emphasis of this work has been to eliminate or further reduce effects that generate systematic errors. Based on realistic projections from our initial measurement, an ultimate sensitivity to neutrino mass of 10 eV is expected. 12 refs., 1 fig

  11. Unexpected pattern of beta-globin mutations in beta-thalassaemia patients from northern Portugal

    OpenAIRE

    Cabeda, J.; Correia, C.; Estevinho, A.; Simões, C.; Amorim, M; L. Pinho; Justiça, B

    1999-01-01

    We characterized the genetic nature of beta-thalassaemia in northern Portugal. Of the 164 patients studied three were beta-thalassaemia major cases (one IVS-1-6/beta degrees 39 and two homozygous IVS-1-110). The analysis of the frequency of each mutation in the families revealed that the codon 6(-A) mutation was unexpectedly frequent (40%) and associated with the beta-globin haplotype E, and not with the usual European and North African CD6(-A) haplotypes. In contrast, the frequency of IVS-1-...

  12. COMBUSTION AREA SOURCES: DATA SOURCES

    Science.gov (United States)

    The report identifies, documents, and evaluates data sources for stationary area source emissions, including solid waste and agricultural burning. Area source emissions of particulate matter, sulfur dioxide, oxides of nitrogen, reactive volatile organic compounds, and carbon mon...

  13. The effect of physical therapy on beta-endorphin levels.

    Science.gov (United States)

    Bender, Tamás; Nagy, György; Barna, István; Tefner, Ildikó; Kádas, Eva; Géher, Pál

    2007-07-01

    Beta-endorphin (betaE) is an important reliever of pain. Various stressors and certain modalities of physiotherapy are potent inducers of the release of endogenous betaE to the blood stream. Most forms of exercise also increase blood betaE level, especially when exercise intensity involves reaching the anaerobic threshold and is associated with the elevation of serum lactate level. Age, gender, and mental activity during exercise also may influence betaE levels. Publications on the potential stimulating effect of manual therapy and massage on betaE release are controversial. Sauna, mud bath, and thermal water increase betaE levels through conveying heat to the tissues. The majority of the techniques for electrical stimulation have a similar effect, which is exerted both centrally and--to a lesser extent--peripherally. However, the parameters of electrotherapy have not yet been standardised. The efficacy of analgesia and the improvement of general well-being do not necessarily correlate with betaE level. Although in addition to blood, increased brain and cerebrospinal fluid betaE levels are also associated with pain, the majority of studies have concerned blood betaE levels. In general, various modalities of physical therapy might influence endorphin levels in the serum or in the cerebrospinal fluid--this is usually manifested by elevation with potential mitigation of pain. However, a causal relationship between the elevation of blood, cerebrospinal fluid or brain betaE levels and the onset of the analgesic action cannot be demonstrated with certainty. PMID:17483960

  14. Genetic analysis of beta1 integrin "activation motifs" in mice

    DEFF Research Database (Denmark)

    Czuchra, Aleksandra; Meyer, Hannelore; Legate, Kyle R;

    2006-01-01

    /beta tails, leading to tail separation and integrin activation. We analyzed mice in which we mutated the tyrosines of the beta1 tail and the membrane-proximal aspartic acid required for the salt bridge. Tyrosine-to-alanine substitutions abolished beta1 integrin functions and led to a beta1 integrin...

  15. Non-stochastic effects of different energy beta emitters on pig and mouse skin

    International Nuclear Information System (INIS)

    In this collaborative study skin areas of various sizes were irradiated with different energy beta emitters. In the post-irradiation period fields were examined for erythema, desquamation, ulceration and dermal necrosis. The aim of the study is to determine the threshold doses for the different biological reactions as a function of the energy of the radiation and the size of skin field irradiated. At St. Bartholomew's Hospital and Oxford the irradiation of mouse and pig skin was carried out using strontium-90 and thulium-170 sources. In addition, mice were irradiated with thallium-204, a slightly lower energy beta emitter than thulium. (author)

  16. Simulation studies for Tin Bolometer Array for Neutrinoless Double Beta Decay

    CERN Document Server

    Singh, V; Mathimalar, S; Nanal, V; Pillay, R G

    2014-01-01

    It is important to identify and reduce the gamma radiation which can be a significant source of background for any double beta decay experiment. The TIN.TIN detector array, which is under development for the search of Neutrinoless Double Beta Decay in $^{124}$Sn, has the potential to utilize the hit multiplicity information to discriminate the gamma background from the events of interest. Monte Carlo simulations for optimizing the design of a Tin detector module has been performed by varying element sizes with an emphasis on the gamma background reduction capabilities of the detector array.

  17. Search for {beta}-delayed fission of the heavy neutron-rich isotope {sup 230}Ac

    Energy Technology Data Exchange (ETDEWEB)

    Shuanggui Yuan; Weifan Yang; Yanbing Xu; Qiangyan Pan; Bing Xiong; Jianjun He; Dong Wang; Yingjun Li; Taotao Ma; Zhenguo Yang [Academia Sinica, Lanzhou, GS (China). Inst. of Modern Physics

    2001-01-01

    The {sup 230}Ra has been produced via multinucleon transfer reaction and dissipative fragmentation by 60 MeV/u {sup 18}O ion irradiation of {sup 232}Th targets. The radium was radiochemically separated from the mixture of thorium and reaction products. Thin Ra sources were prepared and exposed to the mica fission track detectors, and measured by a HPGe gamma detector. It is likely that the {beta}-delayed fission of {sup 230}Ac was observed for the first time and the {beta}-delayed fission probability of {sup 230}Ac was tentatively found to be (1.19{+-}0.40) x 10{sup -8}. (orig.)

  18. The beta-adrenoceptors mediating relaxation of rat oesophageal muscularis mucosae are predominantly of the beta 3-, but also of the beta 2-subtype.

    OpenAIRE

    de Boer, R. E.; Brouwer, F.; Zaagsma, J

    1993-01-01

    1. beta-Adrenoceptor-mediated relaxation of rat oesophageal smooth muscle was investigated by studying the effects of beta 1- and beta 2-selective antagonists on the relaxation induced by (-)-isoprenaline, the beta 2-selective agonists fenoterol and clenbuterol and the beta 3-agonist, BRL 37344. 2. The highly beta 1-selective antagonist CGP 20721A did not antagonize (-)-isoprenaline- or BRL 37344-induced relaxations in concentrations up to 10 microM. Only at 100 microM of CGP 20712A were clea...

  19. News on $\\beta$-delayed particle emission from $^{14}$Be

    CERN Document Server

    Jeppesen, H; Borge, M J G; Cederkäll, J; Fynbo, H O U; Fedoseyev, V N; Hansper, V Y; Jonson, B; Markenroth, K; Mishin, V I; Nilsson, T; Nyman, G; Riisager, K; Tengblad, O; Wilhelmsen Rolander, K

    2002-01-01

    $\\beta$-delayed charged particles from $^{14}$Be have been measured and give an upper limit on $\\beta$-delayed $\\alpha$-particles of B($\\beta\\alpha$) < $\\,6.7\\times\\!10^{-5}$ and a tentative branching ratio on $\\beta$-delayed tritons of $7.5\\times\\!10^{-5}$ < B($\\beta$t) < $\\,3.9\\times\\!10^{-4}$. We combine the knowledge on $\\beta$-delayed particles from $^{14}$Be to deduce information on the $\\beta$-strength distribution.

  20. Sourcing Excellence

    DEFF Research Database (Denmark)

    Adeyemi, Oluseyi

    2011-01-01

    Sourcing Excellence is one of the key performance indicators (KPIs) in this world of ever changing sourcing strategies. Manufacturing companies need to access and diagnose the reliability and competencies of existing suppliers in order to coordinate and develop them. This would help in managing...... excellence in manufacturing companies. In addition, an advanced approach to sourcing involves integrating and coordinating suppliers, common materials, processes, designs and technologies across worldwide buying, design and operating locations. However, since most manufacturing companies do not have well...... integrating the models of JIT sourcing and global sourcing would also add value and enhance excellent sourcing practices. These and other possibilities of sourcing would be considered in this research....

  1. Thermoluminescence dating of stoneware - calibration of the beta dose

    International Nuclear Information System (INIS)

    Thermoluminescence dating involves the use of accurately calibrated beta sources. These sources (e.g. 90Sr) deliver standardized doses to samples which may take the form of coarse grains of quartz deposited on stainless steel discs, fine grains of crushed earthenware deposited on aluminium discs or thick slices of high-fired ceramics. The source needs to be calibrated against a γ-ray emitting source for each type of sample used. Differences in the absorbed dose arise from differences in the thickness of the samples and differences in the transparency of the materials being tested. In this note we consider the influence of transparency by comparing the dose absorbed in 200 μm slices of opaque stoneware with that absorbed in transparent slices of similar thickness. The differences are correlated with the percentage transmission of TL through the slices which is easily measured. A correction can be made to the standard dose rate, commonly stated as the dose rate to fine grains on aluminium, which avoids having to recalibrate the source for each different sample encountered in a dating programme. (author)

  2. Extensions to the Beta Secondary Standard BSS 2

    Science.gov (United States)

    Behrens, R.; Buchholz, G.

    2011-11-01

    Since several years, the irradiation facility for beta radiation, the Beta Secondary Standard BSS 2 developed at PTB, has been in worldwide use for the performance of irradiations with calibrated beta sources. Due to recent developments in eye tumor therapy, in eye lens dosimetry, and in soft- and hardware technology, several extensions have been added to the BSS 2. These extensions are described in this paper: 1. The possibility of using a 106Ru/106Rh beta source was added as this radionuclide is often used in tumor therapy. 2. The (small) contribution due to photon radiation was included in the dose (rate) reported by the BSS 2, as this was missing in the past. 3. The quantity personal dose equivalent at a depth of 3 mm, Hp(3), was implemented due to recent findings on the radio sensitivity of the eye lens regarding cataract induction and the subsequent lowering of the dose limit from 150 mSv down to 20 mSv per year; 4. The correction for ambient conditions (air temperature, pressure, and relative humidity) was improved in order to adequately handle the quantity Hp(3) and in order to extend the range of use beyond 25°C. 5. A checksum test was added to the software to secure the calibration data against (un)intended changes. 6. The connection of the PC and the BSS 2 has been changed to a network interface (TCP/IP) in order to be able to use up-to-date computers not containing a parallel and a serial port. 7. A rod phantom was added in order to make sure the mechanical set-up is of high quality. All these extensions have been implemented in the PTB's BSS 2 model. The routine implementation of extension 1 is still under investigation by the manufacturer. The commercially available BSS 2 will contain extensions 2 to 6 starting approximately in 2012, while extension 7 has already been incorporated since 2011. Extensions 2 to 4 will also be available for old BSS 2 versions via a software update, starting approximately at the beginning of 2012. Extension 6 will be

  3. Beta-Negative Binomial Process and Poisson Factor Analysis

    OpenAIRE

    Zhou, Mingyuan; Hannah, Lauren; Dunson, David; Carin, Lawrence

    2011-01-01

    A beta-negative binomial (BNB) process is proposed, leading to a beta-gamma-Poisson process, which may be viewed as a "multi-scoop" generalization of the beta-Bernoulli process. The BNB process is augmented into a beta-gamma-gamma-Poisson hierarchical structure, and applied as a nonparametric Bayesian prior for an infinite Poisson factor analysis model. A finite approximation for the beta process Levy random measure is constructed for convenient implementation. Efficient MCMC computations are...

  4. Reference beta radiations for calibrating dosemeters and dose ratemeters and for determining their response as a function of beta radiation energy. 1. ed.

    International Nuclear Information System (INIS)

    This International Standard specifies the requirements for reference beta radiations produced by radionuclide sources to be used for the calibration of protection level dosemeters and dose ratemeters, and for the determination of their response as a function of beta energy. It gives the characteristics of radionuclides which have been used to produce reference beta radiations, gives examples of suitable source constructions and describes methods for the measurement of the residual maximum beta energy and the absorbed dose rate at a depth of 7 mg·cm-2 in a semi-infinite tissue-equivalent medium. The energy range involved lies between 66 keV and 3.6 MeV and the absorbed dose rates are in the range from about 10 μGy·h-1 (1 mrad·h-1) to at least 10 Gy·h-1 (103 rad·h-1). This International Standard proposes two series of beta reference radiations from which the radiation necessary for determining the characteristics (calibration and energy response) of an instrument shall be selected. Series 1 reference radiations are produced by radionuclide sources used with beam flattening filters designed to give uniform dose rates over a large area at a specific distance. The proposed sources of 90Sr+90Y, 204TI and 147Pm produce maximum dose rates of approximately 5mGy·h-1 (0.5 rad·h-1). Series 2 reference radiations are produced without the use of beam flattening filters which allows a range of source-to-calibration plane distances to be used. Close to the sources only relatively small areas of uniform dose rate are produced but this Series has the advantage of extending the energy and dose rate ranges beyond those of Series 1. The radionuclides used are those of Series 1 with the addition of the radionuclides 14C and 106Ru+106Rh; these sources produce dose rates of up to 10 Gy·h-1 (103 rad·h-1)

  5. Oligomerization and toxicity of A{beta} fusion proteins

    Energy Technology Data Exchange (ETDEWEB)

    Caine, Joanne M., E-mail: Jo.Caine@csiro.au [CSIRO Materials Science and Engineering and the Preventive Health Flagship, Parkville, Victoria (Australia); Bharadwaj, Prashant R. [CSIRO Materials Science and Engineering and the Preventive Health Flagship, Parkville, Victoria (Australia); Centre for Excellence for Alzheimer' s Disease Research and Care, School of Exercise, Biomedical and Health Sciences, Edith Cowan University, Western Australia (Australia); Sankovich, Sonia E. [CSIRO Materials Science and Engineering and the Preventive Health Flagship, Parkville, Victoria (Australia); Ciccotosto, Giuseppe D. [The Department of Pathology and Bio21 Molecular Science and Biotechnology Institute, The University of Melbourne, Victoria 3010 (Australia); Streltsov, Victor A.; Varghese, Jose [CSIRO Materials Science and Engineering and the Preventive Health Flagship, Parkville, Victoria (Australia)

    2011-06-10

    Highlights: {yields} We expressed amyloid-{beta} (A{beta}) peptide as a soluble maltose binding protein fusion (MBP-A{beta}42 and MBP-A{beta}16). {yields} The full length A{beta} peptide fusion, MBP-A{beta}42, forms oligomeric species as determined by SDS-PAGE gels, gel filtration and DLS. {yields} The MBP-A{beta}42, but not MBP-A{beta}16 or MBP alone, is toxic to both yeast and mammalian cells as determined by toxicity assays. -- Abstract: This study has found that the Maltose binding protein A{beta}42 fusion protein (MBP-A{beta}42) forms soluble oligomers while the shorter MBP-A{beta}16 fusion and control MBP did not. MBP-A{beta}42, but neither MBP-A{beta}16 nor control MBP, was toxic in a dose-dependent manner in both yeast and primary cortical neuronal cells. This study demonstrates the potential utility of MBP-A{beta}42 as a reagent for drug screening assays in yeast and neuronal cell cultures and as a candidate for further A{beta}42 characterization.

  6. Beta Gyres in Global Analysis Fields

    Institute of Scientific and Technical Information of China (English)

    Sun-Hee KIM; H.Joe KWON; R.L.ELSBERRY

    2009-01-01

    A three-component decomposition is applied to global analysis data to show the existence of a beta gyre,which causes Tropical Cyclone (TC) to drift from a large-scale environmental steering current.Analyses from the Global Data Assimilation and Prediction System (GDAPS) of the Korea Meteorological Administration (KMA),the Global Forecast System (GFS) of NCEP,and the Navy Operational Global Atmospheric Prediction System (NOGAPS) are used in this study.The structure of the beta gyre obtained in our analyses is in good agreement with the theoretical structure,with a cyclonic circulation to the southwest of the TC center,an anticyclonic circulation to the northeast,and a ventilation flow directed northwestward near the center.The circulation of the beta gyre is strongest at the 850-hPa level where the cyclonically swirling primary circulation is strongest,and decreases with height,in a pyramid shape similar to the primary circulation.The individual structure of the beta gyre is case- and model-dependent.At a certain analysis time,one model may clearly reveal a well-defined beta gyre,but the other models may not.Within one model,the beta gyre may be well defined at some analysis times,but not at other times.The structure of the beta gyre in the analysis field is determined by the nature of the vortex initialization scheme and the model behavior during the 6-h forecast in the operational data assimilation cycle.

  7. Metrological characteristics of the new BSS2 beta secondary standard system

    International Nuclear Information System (INIS)

    Due to the increased interest and the importance of beta radiation dosimetry for radiation protection purposes, the Centro de Desenvolvimento da Tecnologia Nuclear. MG, Brazil, acquired the newest Beta Secondary Standard system (BSS2) in order to replace the old BSS1 model, with the goal of implement a beta radiation metrology laboratory and provide the corresponding reference radiation. The new system BSS2, unique in Latin America, requires operational testing and metrological characterization for reliability purposes. For this, some comparative investigations of the two systems were made. The influence of opening and closing the shutter in the final dose of radiation was identified as the highest in the BSS2 in relation to the one founded in BSS1, justified by the structural difference of the shutters of the systems and the reproducibility of source-detector geometry was better in BSS2, because of the robustness of the same

  8. Assessment of Base Line Concentrations for Trace Elements and Total Alpha, Beta Gross for Some Herbs

    International Nuclear Information System (INIS)

    Five marked brands of drinking herbs, commonly consumed by Egyptian population were collected from local market. Concentration of essential and toxic elements have been measured by atomic absorption spectrometry (AAS). Also, the total alpha and beta gross activities in all samples were measured using ultra low level liquid scintillation counting system (LSC). Cinnamon was found to contain relatively high amounts of essential as well as toxic elements but the measurement using LSC revealed no detection for both alpha and beta gross activity. The annual effective doses for different herbs were also calculated referring to the dose conversion factor (dose per unit intake) for both alpha and beta gross activity when dealing with naturally occurring radionuclides. The study also shows that these herbs are additional source of trace heavy elements intake

  9. Single fiber beta detector for stereotactic biopsy and intraoperative lumpectomy of breast cancer

    International Nuclear Information System (INIS)

    We have developed an intraoperative probe for use in early detection of breast cancer and aiding lumpectomy. The probe consists of a small plastic scintillator, 0.8mm dia and 3mm long, coupled to a single clear optical-fiber strand, and solid state photomultiplier. Due to the small size of the probe, it can be placed inside of a small gauge biopsy needle. The scintillator is very efficient in detecting betas and positrons while being very in efficient to energetic gammas due to small size and low density. High quantum efficiency, 80%, and high gain obtainable, solid state photomultiplier makes the probe very low noise device in detecting beta particles. Intrinsic resolution of the probe is expected to be around 1 mm. Preliminary results using beta sources and a rat bearing R320 adenocarcinoma tumor were very successful

  10. Application of whole-body personal TL dosemeters in mixed field beta-gamma radiation

    International Nuclear Information System (INIS)

    Application of whole-body personal TL dosemeters based on a high-sensitivity LiF:Mg,Cu,P (MCP-N) in mixed field beta-gamma radiation has been characterised. The measurements were carried out with 90Sr/90Y, 85Kr and 137Cs point sources to calculate the energy response and linearity of the TLD response in a dose range of 0.1-30 mSv. From the result, calibration curves were obtained, enabling the readout of individual dose equivalent Hp(10) from gamma radiation and Hp(0.07) from beta radiation in mixed field beta-gamma. Limitation of the methodology and its application are presented and discussed. (authors)

  11. Characterization of OSL commercial dosimeters using a hand phantom, in standard beta radiation beams

    International Nuclear Information System (INIS)

    In this study, a hand phantom was developed and tested with Al2O3:C detectors (nanodots, Landauer) and the optically stimulated luminescence (OSL) technique. This paper shows the results of a characterization study of Al2O3:C detectors at the hand phantom, to simulate operations at a nuclear medicine service. The OSL detectors were exposed to standard beta radiation beans of the beta secondary standard system of the Calibration Laboratory at IPEN, with 90Sr + 90Y, 85Kr and 147Pm sources. The detectors were optically treated prior each reutilization. The results obtained show that for monitoring of workers exposed to beta radiation, the technique and the material are useful, but the energy dependence of the OSL response of Al2O3: C has to be taken into consideration. (author)

  12. Computational methods for analyzing the transmission characteristics of a beta particle magnetic analysis system

    Science.gov (United States)

    Singh, J. J.

    1979-01-01

    Computational methods were developed to study the trajectories of beta particles (positrons) through a magnetic analysis system as a function of the spatial distribution of the radionuclides in the beta source, size and shape of the source collimator, and the strength of the analyzer magnetic field. On the basis of these methods, the particle flux, their energy spectrum, and source-to-target transit times have been calculated for Na-22 positrons as a function of the analyzer magnetic field and the size and location of the target. These data are in studies requiring parallel beams of positrons of uniform energy such as measurement of the moisture distribution in composite materials. Computer programs for obtaining various trajectories are included.

  13. A measurement system for alpha and beta surface emission rate using MWPC

    Science.gov (United States)

    Lin, Ye; Fang, Fang; Ren, Jia-Fu; He, Lin-Feng; Tang, Fang-Dong; Xu, Yi-He; Ding, Wei-Cheng

    2015-05-01

    We have developed a large area multi-wire proportional counter (MWPC) as a standard for the measurement of alpha and beta surface emission rate at the Shanghai Institute of Measurement and Testing Technology (SIMT). To shorten the preparation time for chamber gas refilling, a self-designed gas control unit was adopted. Various characteristics of the system have been studied. The uncertainties were analysed. Three certified alpha plane sources (Am-241) and six certified beta plane sources (Tl-204 and Sr-90/Y-90) were measured by this system. The results show excellent agreement with the surface emission rate reported by the National Institute of Measuring, China (NIM) that En values of all measured sources are within ±1. Supported by National Natural Science Foundation of China (41204133)

  14. Study of systematic effects in beta decay measurements with AgReO4 calorimeters

    CERN Document Server

    Monfardini, A; Cremonesi, O; Nucciotti, A; Sisti, M; Monfardini, Alessandro; Capozzi, Francesca; Cremonesi, Oliviero; Nucciotti, Angelo; Sisti, Monica

    2006-01-01

    AgReO4 microcalorimeters are planned to be used again in the next generation of calorimetric neutrino mass experiments with sensitivity down to 0.2 eV. The understanding and characterization of all possible sources of systematic uncertainties is crucial. In this work we focus on two of these sources, which have been studied in the 10 detectors of the Milano AgReO4 array experiment (MIBETA): a) the solid-state Beta Environmental Fine Structure (BEFS) observed for the first time in AgReO4; b) the detector energy response for internal beta events, which has been investigated with a dedicated measurement using a 44Ti gamma source. The possible effects on neutrino mass experiments due to the incomplete understanding of these two aspects are discussed.

  15. Detrimental effects of beta-blockers in COPD - A concern for nonselective beta-blockers

    NARCIS (Netherlands)

    van der Woude, HJ; Zaagsma, J; Postma, DS; Winter, TH; van Hulst, M; Aalbers, R

    2005-01-01

    Introduction: beta-Blockers are known to worsen FEV1 and airway hyperresponsiveness (AHR) in patients with asthma. Both characteristics determine the outcome of COPD, a disease with frequent cardiac comorbidity requiring beta-blocker treatment. Design: A double-blind, placebo-controlled, randomized,

  16. Mrp2 is essential for estradiol-17 beta(beta-D-glucuronide)-induced cholestasis in rats

    NARCIS (Netherlands)

    Huang, LY; Smit, JW; Meijer, DKF; Vore, M

    2000-01-01

    The present study evaluates the roles of the multidrug resistance-1 P-glycoprotein, Mdr1a/1b, the bile salt export pump (Bsep), and the multidrug resistance-associated protein-2 (Mrp2) in mediating cholestasis induced by estradiol-17 beta(beta-D-glucuronide) (E(2)17G). Administration of [H-3]E(2)17G

  17. Production of beta-xylanase and beta-xylosidase by the extremely halophilic archaeon Halorhabdus utahensis

    DEFF Research Database (Denmark)

    Wainø, M.; Ingvorsen, K.

    2003-01-01

    The extremely halophilic archaeon, Halorhabdus utahensis, isolated from the Great Salt Lake, Utah, produced beta-xylanase and beta-xylosidase activities. Both enzymes were active over a broad NaCl range from near zero to 30% NaCl when tested with culture broth. A broad NaCl optimum was observed f...

  18. On Gamow-Teller strength distributions for $\\beta\\beta$-decaying nuclei within continuum-QRPA

    CERN Document Server

    Igashov, S Yu; Faessler, Amand; Urin, M H

    2010-01-01

    An isospin-selfconsistent pn-continuum-QRPA approach is formulated and applied to describe the Gamow-Teller strength distributions for $\\beta\\beta$-decaying open-shell nuclei. The calculation results obtained for the pairs of nuclei $^{76}$Ge-Se, $^{100}$Mo-Ru, $^{116}$Cd-Sn, and $^{130}$Te-Xe are compared with available experimental data.

  19. SU-E-J-03: A Comprehensive Comparison Between Alpha and Beta Emitters for Cancer Radioimmunotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Huang, C.Y. [University of Sydney, Camperdown, NSW (Australia); Guatelli, S [University of Wollongong, Wollongong, NSW (Australia); Oborn, B [Illawarra Cancer Care Centre, Wollongong, NSW (Australia); Allen, B [University of Western Sydney, Liverpool, NSW (Australia)

    2014-06-01

    Purpose: The purpose of this study is to perform a comprehensive comparison of the therapeutic efficacy and cytotoxicity of alpha and beta emitters for Radioimmunotherapy (RIT). For each stage of cancer development, specific models were built for the separate objectives of RIT to be addressed:a) kill isolated cancer cells in transit in the lymphatic and vascular circulation,b) regress avascular cell clusters,c) regress tumor vasculature and tumors. Methods: Because of the nature of short range, high LET alpha and long energy beta radiation and heterogeneous antigen expression among cancer cells, the microdosimetric approach is essential for the RIT assessment. Geant4 based microdosimetric models are developed for the three different stages of cancer progression: cancer cells, cell clusters and tumors. The energy deposition, specific energy resulted from different source distribution in the three models was calculated separately for 4 alpha emitting radioisotopes ({sup 211}At, {sup 213}Bi, {sup 223}Ra and {sup 225}Ac) and 6 beta emitters ({sup 32}P, {sup 33}P, {sup 67}Cu, {sup 90}Y, {sup 131}I and {sup 177}Lu). The cell survival, therapeutic efficacy and cytotoxicity are determined and compared between alpha and beta emitters. Results: We show that internal targeted alpha radiation has advantages over beta radiation for killing isolated cancer cells, regressing small cell clusters and also solid tumors. Alpha particles have much higher dose specificity and potency than beta particles. They can deposit 3 logs more dose than beta emitters to single cells and solid tumor. Tumor control probability relies on deep penetration of radioisotopes to cancer cell clusters and solid tumors. Conclusion: The results of this study provide a quantitative understanding of the efficacy and cytotoxicity of RIT for each stage of cancer development.

  20. SU-E-J-03: A Comprehensive Comparison Between Alpha and Beta Emitters for Cancer Radioimmunotherapy

    International Nuclear Information System (INIS)

    Purpose: The purpose of this study is to perform a comprehensive comparison of the therapeutic efficacy and cytotoxicity of alpha and beta emitters for Radioimmunotherapy (RIT). For each stage of cancer development, specific models were built for the separate objectives of RIT to be addressed:a) kill isolated cancer cells in transit in the lymphatic and vascular circulation,b) regress avascular cell clusters,c) regress tumor vasculature and tumors. Methods: Because of the nature of short range, high LET alpha and long energy beta radiation and heterogeneous antigen expression among cancer cells, the microdosimetric approach is essential for the RIT assessment. Geant4 based microdosimetric models are developed for the three different stages of cancer progression: cancer cells, cell clusters and tumors. The energy deposition, specific energy resulted from different source distribution in the three models was calculated separately for 4 alpha emitting radioisotopes (211At, 213Bi, 223Ra and 225Ac) and 6 beta emitters (32P, 33P, 67Cu, 90Y, 131I and 177Lu). The cell survival, therapeutic efficacy and cytotoxicity are determined and compared between alpha and beta emitters. Results: We show that internal targeted alpha radiation has advantages over beta radiation for killing isolated cancer cells, regressing small cell clusters and also solid tumors. Alpha particles have much higher dose specificity and potency than beta particles. They can deposit 3 logs more dose than beta emitters to single cells and solid tumor. Tumor control probability relies on deep penetration of radioisotopes to cancer cell clusters and solid tumors. Conclusion: The results of this study provide a quantitative understanding of the efficacy and cytotoxicity of RIT for each stage of cancer development

  1. On the brightness of diluted photon source in synchrotron light facilities

    Energy Technology Data Exchange (ETDEWEB)

    Ivanyan, M. E-mail: ivanian@asls.candle.am; Martirosyan, Y.; Tsakanov, V

    2004-10-01

    The undulator radiation spectral brightness in storage ring is studied taking into account the effects of the electron beam oscillating trajectory and the beam transverse size variation along the undulator. The modified optimal beta function at the source point to reach maximum brightness is obtained that is in direct relation with the emitted photons wavelength. It is shown that the maximum spectral brightness in long wavelength range is achieved with low beta lattice, while in short wavelength range with larger beta.

  2. Competition of $\\beta$-delayed protons and $\\beta$-delayed $\\gamma$ rays in $^{56}$Zn and the exotic $\\beta$-delayed $\\gamma$-proton decay

    CERN Document Server

    Orrigo, S E A; Fujita, Y; Blank, B; Gelletly, W; Agramunt, J; Algora, A; Ascher, P; Bilgier, B; Cáceres, L; Cakirli, R B; Fujita, H; Ganioglu, E; Gerbaux, M; Giovinazzo, J; Grévy, S; Kamalou, O; Kozer, H C; Kucuk, L; Kurtukian-Nieto, T; Molina, F; Popescu, L; Rogers, A M; Susoy, G; Stodel, C; Suzuki, T; Tamii, A; Thomas, J C

    2016-01-01

    Remarkable results have been published recently on the $\\beta$ decay of $^{56}$Zn. In particular, the rare and exotic $\\beta$-delayed $\\gamma$-proton emission has been detected for the first time in the $fp$ shell. Here we focus the discussion on this exotic decay mode and on the observed competition between $\\beta$-delayed protons and $\\beta$-delayed $\\gamma$ rays from the Isobaric Analogue State.

  3. Regulation of glycogen synthase kinase-3{beta} (GSK-3{beta}) after ionizing radiation; Regulation der Glykogen Synthase Kinase-3{beta} (GSK-3{beta}) nach ionisierender Strahlung

    Energy Technology Data Exchange (ETDEWEB)

    Boehme, K.A.

    2006-12-15

    Glycogen Synthase Kinase-3{beta} (GSK-3{beta}) phosphorylates the Mdm2 protein in the central domain. This phosphorylation is absolutely required for p53 degradation. Ionizing radiation inactivates GSK-3{beta} by phosphorylation at serine 9 and in consequence prevents Mdm2 mediated p53 degradation. During the work for my PhD I identified Akt/PKB as the kinase that phosphorylates GSK-3{beta} at serine 9 after ionizing radiation. Ionizing radiation leads to phosphorylation of Akt/PKB at threonine 308 and serine 473. The PI3 Kinase inhibitor LY294002 completely abolished Akt/PKB serine 473 phosphorylation and prevented the induction of GSK-3{beta} serine 9 phosphorylation after ionizing radiation. Interestingly, the most significant activation of Akt/PKB after ionizing radiation occurred in the nucleus while cytoplasmic Akt/PKB was only weakly activated after radiation. By using siRNA, I showed that Akt1/PKBa, but not Akt2/PKB{beta}, is required for phosphorylation of GSK- 3{beta} at serine 9 after ionizing radiation. Phosphorylation and activation of Akt/PKB after ionizing radiation depends on the DNA dependent protein kinase (DNA-PK), a member of the PI3 Kinase family, that is activated by free DNA ends. Both, in cells from SCID mice and after knockdown of the catalytic subunit of DNA-PK by siRNA in osteosarcoma cells, phosphorylation of Akt/PKB at serine 473 and of GSK-3{beta} at serine 9 was completely abolished. Consistent with the principle that phosphorylation of GSK-3 at serine 9 contributes to p53 stabilization after radiation, the accumulation of p53 in response to ionizing radiation was largely prevented by downregulation of DNA-PK. From these results I conclude, that ionizing radiation induces a signaling cascade that leads to Akt1/PKBa activation mediated by DNA-PK dependent phosphorylation of serine 473. After activation Akt1/PKBa phosphorylates and inhibits GSK-3{beta} in the nucleus. The resulting hypophosphorylated form of Mdm2 protein is no longer

  4. Dosimetric methodology for extremities of individuals occupationally exposed to beta radiation using the optically stimulated luminescence technique; Metodologia dosimetrica para extremidades em individuos ocupacionalmente expostos a radiacao beta por meio da tecnica de luminescencia opticamente estimulada

    Energy Technology Data Exchange (ETDEWEB)

    Pinto, Teresa Cristina Nathan Outeiro

    2010-07-01

    A dosimetric methodology was established for the determination of extremity doses of individuals occupationally exposed to beta radiation, using Al{sub 2}O{sub 3}:C detectors and the optically stimulated luminescence (OSL) reader system microStar, Landauer. The main parts of the work were: characterization of the dosimetric material Al{sub 2}O{sub 3}:C using the OSL technique; establishment of the dose evaluation methodology; dose rate determination of beta radiation sources; application of the established method in a practical test with individuals occupationally exposed to beta radiation during a calibration simulation of clinical applicators; validation of the methodology by the comparison between the dose results of the practical test using the OSL and the thermoluminescence (TL) techniques. The results show that both the OSL Al-2O{sub 3}:C detectors and the technique may be utilized for individual monitoring of extremities and beta radiation. (author)

  5. Problems with packaged sources in foreign countries

    Energy Technology Data Exchange (ETDEWEB)

    Abeyta, Cristy L [Los Alamos National Laboratory; Matzke, James L [Los Alamos National Laboratory; Zarling, John [Los Alamos National Laboratory; Tompkin, J. Andrew [Los Alamos National Laboratory

    2010-01-01

    The Global Threat Reduction Initiative's (GTRI) Off-Site Source Recovery Project (OSRP), which is administered by the Los Alamos National Laboratory (LANL), removes excess, unwanted, abandoned, or orphan radioactive sealed sources that pose a potential threat to national security, public health, and safety. In total, GTRI/OSRP has been able to recover more than 25,000 excess and unwanted sealed sources from over 825 sites. In addition to transuranic sources, the GTRI/OSRP mission now includes recovery of beta/gamma emitting sources, which are of concern to both the U.S. government and the International Atomic Energy Agency (IAEA). This paper provides a synopsis of cooperative efforts in foreign countries to remove excess and unwanted sealed sources by discussing three topical areas: (1) The Regional Partnership with the International Atomic Energy Agency; (2) Challenges in repatriating sealed sources; and (3) Options for repatriating sealed sources.

  6. Field transportable beta spectrometer. Innovative technology summary report

    International Nuclear Information System (INIS)

    The objective of the Large-Scale Demonstration Project (LSDP) is to select and demonstrate potentially beneficial technologies at the Argonne National Laboratory-East (ANL) Chicago Pile-5 Test Reactor (CP-5). The purpose of the LSDP is to demonstrate that by using innovative and improved deactivation and decommissioning (D and D) technologies from various sources, significant benefits can be achieved when compared to baseline D and D technologies. One such capability being addressed by the D and D Focus Area is rapid characterization for facility contaminants. The technology was field demonstrated during the period January 7 through January 9, 1997, and offers several potential benefits, including faster turn-around time, cost reduction, and reduction in secondary waste. This report describes a PC controlled, field-transportable beta counter-spectrometer which uses solid scintillation coincident counting and low-noise photomultiplier tubes to count element-selective filters and other solid media. The dry scintillation counter used in combination with an element-selective technology eliminates the mess and disposal costs of liquid scintillation cocktails. Software in the instrument provides real-time spectral analysis. The instrument can detect and measure Tc-99, Sr-90, and other beta emitters reaching detection limits in the 20 pCi range (with shielding). Full analysis can be achieved in 30 minutes. The potential advantages of a field-portable beta counter-spectrometer include the savings gained from field generated results. The basis for decision-making is provided with a rapid turnaround analysis in the field. This technology would be competitive with the radiometric analysis done in fixed laboratories and the associated chain of custody operations

  7. Field transportable beta spectrometer. Innovative technology summary report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-12-01

    The objective of the Large-Scale Demonstration Project (LSDP) is to select and demonstrate potentially beneficial technologies at the Argonne National Laboratory-East (ANL) Chicago Pile-5 Test Reactor (CP-5). The purpose of the LSDP is to demonstrate that by using innovative and improved deactivation and decommissioning (D and D) technologies from various sources, significant benefits can be achieved when compared to baseline D and D technologies. One such capability being addressed by the D and D Focus Area is rapid characterization for facility contaminants. The technology was field demonstrated during the period January 7 through January 9, 1997, and offers several potential benefits, including faster turn-around time, cost reduction, and reduction in secondary waste. This report describes a PC controlled, field-transportable beta counter-spectrometer which uses solid scintillation coincident counting and low-noise photomultiplier tubes to count element-selective filters and other solid media. The dry scintillation counter used in combination with an element-selective technology eliminates the mess and disposal costs of liquid scintillation cocktails. Software in the instrument provides real-time spectral analysis. The instrument can detect and measure Tc-99, Sr-90, and other beta emitters reaching detection limits in the 20 pCi range (with shielding). Full analysis can be achieved in 30 minutes. The potential advantages of a field-portable beta counter-spectrometer include the savings gained from field generated results. The basis for decision-making is provided with a rapid turnaround analysis in the field. This technology would be competitive with the radiometric analysis done in fixed laboratories and the associated chain of custody operations.

  8. Thermoluminescence dosimetric characteristics of beta irradiated common salt

    International Nuclear Information System (INIS)

    Considering the usage of salt by the humans the Thermoluminescence (TL) dosimetric characteristics of common salt are studied. Common salt is known as good TL dosimetric material. The salt samples (NaCl) were collected from different countries like USA, UK, Italy, France, China, Singapore, Australia and Japan which are used for the cooking purpose. The present paper reports their usage as an, accidental dosimeter in case of accidental fallout of nuclear fragments. All the samples were given a beta dose of 1 Gy to 200 Gy from a 90Sr beta source with 50mCi strength (1.85GBq). TL of beta irradiated salt specimens is used in the form of disc. The disks are prepared using silicon spray sprayed on to a stainless steel disc of 10 mm diameter and 0.1 mm thickness and free flow salt is sprayed on to the disk, which are used in the present investigation. The average weight of salt grains stick to the stainless steel disc is around 1 mg. All the discs are kept in an oven maintained at 150 deg C for an hour to remove any water molecules absorbed by the sample. The TL glow curves were recorded immediately after excitation and also after 24, 50, 100, 200, 300, 400 and 500 hours of storage at room temperature in an air tight and light tight aluminum chamber. The humidity levels in the laboratory are around 50 to 60 % while performing the present experiment. TL was recorded using the Necleonix Systems, TL apparatus. Varieties of Tl peaks were observed in the range 125 to 325 deg C. Most of the peaks are well resolved having maximum intensity around 220 deg C. The TL exhibited by most of the salt samples exhibit good TL dosimetric properties. (author)

  9. Mechanical design and analysis for a low beta squeezed half-wave resonator

    CERN Document Server

    He, Shoubo; Zhang, Shenghu; Yue, Weiming; Zhang, Cong; Wang, Zhijun; Wang, Ruoxu; Xu, Mengxin; Huang, Shichun; Huang, Yulu; Jiang, Tiancai; Wang, Fengfeng; Zhang, Shengxue; Zhao, Hongwei

    2013-01-01

    A superconducting half-wave resonator (HWR) of frequency=162.5 MHz and {\\beta}=0.09 has been developed at Institute of Modern Physics. Mechanical stability of the low beta HWR cavity is a big challenge in cavity design and optimization. The mechanical deformations of a radio frequency superconducting cavity could be a source of instability, both in continues wave(CW) operation or in pulsed mode. Generally, the lower beta cavities have stronger Lorentz force detuning than that of the higher beta cavities. In this paper, a basic design consideration in the stiffening structure for the detuning effect caused by helium pressure and Lorentz force has been presented. The mechanical modal analysis has been investigated with finite element method(FEM). Based on these considerations, a new stiffening structure has been promoted for the HWR cavity. The computation results concerning the frequency shift show that the low beta HWR cavity with new stiffening structure has low frequency sensitivity coefficient, Lorentz for...

  10. Measurement of the beta-neutrino correlation in laser trapped {sup 21}Na

    Energy Technology Data Exchange (ETDEWEB)

    Scielzo, Nicholas David

    2003-06-01

    Trapped radioactive atoms are an appealing source for precise measurements of the beta-neutrino correlation coefficient, a, since the momentum of the neutrino can be inferred from the detection of the unperturbed low-energy recoil daughter nucleus. Sodium-21 is produced on-line at the 88'' cyclotron at Lawrence Berkeley National Laboratory, and 8e5 atoms have been maintained in a magneto-optical trap. A static electric field draws daughter Neon-21 ions to a microchannel plate detector and betas are detected in coincidence with a plastic scintillator beta detector. The Neon-21 time-of-flight distribution determines the beta neutrino correlation coefficient, a. The resulting charge-state distribution is compared to a simple model based on the sudden approximation which suggests a small but important contribution from nuclear recoil-induced ionization. A larger than expected fraction of the daughters are detected in positive charge-states, but no dependence on either the beta or recoil nucleus energy was observed. We find a = 0.5243 plus or minus 0.0092, which is in 3.6 sigma disagreement with the Standard Model prediction of a = 0.559 plus or minus 0.003. Aside from a deviation from the Standard Model, a possible explanation for the discrepancy is that the branching ratio to the first excited state is in error.

  11. Comparison of three enzyme immunoassays for measuring 17beta-estradiol in flushed dairy manure wastewater.

    Science.gov (United States)

    Hanselman, Travis A; Graetz, Donald A; Wilkie, Ann C

    2004-01-01

    Natural steroidal estrogens are an environmental concern because low nanogram per liter concentrations in water can adversely affect aquatic vertebrate species by disrupting the normal function of their endocrine systems. There is a critical need to accurately measure estrogens in dairy wastes, a potential source of estrogens such as 17beta-estradiol, to assess the risk of estrogen contamination of agricultural drainage waters resulting from land application. Commercially available enzyme immunoassay (EIA) kits have been used for measuring 17beta-estradiol in livestock manure, but it is not known if different EIAs provide similar results. We compared three EIAs by measuring 17beta-estradiol in two samples of flushed dairy manure wastewater (FDMW). The measured concentrations of 17beta-estradiol in FDMW differed according to the immunoassay used. The differences were attributed to a matrix interference associated with coextracted humic substances. Future research should develop methods that enable routine measurement of 17beta-estradiol in livestock wastes by more conclusive analytical techniques such as gas chromatography-mass spectrometry. PMID:15356254

  12. Multi-Cell Reduced-Beta Elliptical Cavities for a Proton Linac

    Energy Technology Data Exchange (ETDEWEB)

    Carneiro, J.-P.; Gonin, I.; Solyak, N.; Yakovlev, V.; /Fermilab; Mustapha, B.; Ostroumov, P.N.; /Argonne; Hartung, W.; /Michigan State U., NSCL

    2009-05-01

    A superconducting cavity has been designed for acceleration of particles traveling at 81% the speed of light ({beta} = 0.81). The application of interest is an 8 GeV proton linac proposed for a Fermilab upgrade; at present, the cavity is to be used from 420 MeV to 1.3 GeV. The cavity is similar to the 805 MHz high-{beta} cavity developed for the Spallation Neutron Source Linac, but the resonant frequency (1.3 GHz) and beam tube diameter (78 mm) are the same as for the {beta} = 1 cavities developed for the TESLA Test Facility. Four single-cell prototype cavities have been fabricated and tested. Two multi-cell prototypes have also been fabricated, but they have not yet been tested. The original concept was for an 8-cell cavity, but the final design and prototyping was done for 7-cells. An 11-cell cavity was proposed recently to allow the cryomodules for the {beta} = 0.81 cavity and downstream 9-cell {beta} = 1 cavities to be identical. The choice of number of cells per cavity affects the linac design in several ways. The impact of the number of cells in the 8 GeV linac design will be explored in this paper. Beam dynamics simulations from the ANL code TRACK will be presented.

  13. NADPH oxidase mediates glucolipotoxicity-induced beta cell dysfunction--clinical implications.

    Science.gov (United States)

    McCarty, Mark F; Barroso-Aranda, Jorge; Contreras, Francisco

    2010-03-01

    An impairment of glucose-stimulated insulin secretion--reflecting decreased glucokinase expression--and a moderate decrease in beta cell mass attributable to increased apoptosis, constitute the key features of beta cell failure in type 2 diabetes. Oxidative stress, provoked by prolonged exposure to excessive levels of glucose and/or fatty acids (glucolipotoxicity), appears to be a key mediator of these defects. Oxidant-provoked JNK activation induces nuclear export of the PDX-1 transcription factor, required for expression of glucokinase and other beta cell proteins. Conversely, increases in cAMP induced by incretin hormones promote the nuclear importation of PDX-1, counteracting the diabetogenic impact of oxidant stress; this may explain the utility of measures that slow dietary carbohydrate absorption for diabetes prevention. The ability of oxidative stress to boost apoptosis in beta cells is poorly understood, but may also entail JNK activation. Recent work establishes a phagocyte-type NADPH oxidase as the chief source of glucotoxicity-mediated oxidative stress in beta cells. Since bilirubin is now known to function physiologically as an inhibitor of NADPH oxidase, and phycocyanobilin (PCB) derived from spirulina likewise can inhibit this enzyme complex, supplemental PCB may have utility in the prevention and control of diabetes, and Gilbert syndrome, associated with chronically elevated free bilirubin, may be associated with decreased diabetes risk. PMID:19576699

  14. Dosimetric methodology for extremities of individuals occupationally exposed to beta radiation using the optically stimulated luminescence technique

    International Nuclear Information System (INIS)

    A dosimetric methodology was established for the determination of extremity doses of individuals occupationally exposed to beta radiation, using Al2O3:C detectors and the optically stimulated luminescence (OSL) reader system microStar, Landauer. The main parts of the work were: characterization of the dosimetric material Al2O3:C using the OSL technique; establishment of the dose evaluation methodology; dose rate determination of beta radiation sources; application of the established method in a practical test with individuals occupationally exposed to beta radiation during a calibration simulation of clinical applicators; validation of the methodology by the comparison between the dose results of the practical test using the OSL and the thermoluminescence (TL) techniques. The results show that both the OSL Al-2O3:C detectors and the technique may be utilized for individual monitoring of extremities and beta radiation. (author)

  15. Flight time beta spectrometer with position sensitive detectors for electronic structure investigation at points of hydrogen adsorption on surface

    International Nuclear Information System (INIS)

    The basis of flight time beta spectrometer for investigation of electronic emission with energy not over 500 eV have been created. This device will be used for carrying out the first study of electronic structure at the points of hydrogen adsorption through the measuring of spectra of Auger relaxation electrons emitted by the system investigated surface-tritium. The momentum resolution of beta spectrometer accounts for (0,1 - 0,2)% at 'traditional' solid angle equals to 0,25% from 4π sr owing to the use positron sensitive start and stop detectors on a basis of microchannel plates. Taking into consideration that the area of our beta source is minimum 100 times larger as compared to 'traditional' spectrometers and a spectrum here is registered simultaneously over all energy interval containing useful information, we obtain high quality beta spectrometer. (author)

  16. Patterns of alpha, beta and gamma diversity of the herpetofauna in Mexico’s Pacific lowlands and adjacent interior valleys

    Directory of Open Access Journals (Sweden)

    García, A.

    2007-12-01

    Full Text Available The latitudinal distribution patterns of alpha, beta and gamma diversity of reptiles, amphibians and herpetofauna were analyzed using individual binary models of potential distribution for 301 species predicted by ecological modelling for a grid of 9,932 quadrants of ~25 km2 each. We arranged quadrants in 312 latitudinal bands in which alpha, beta and gamma values were determined. Latitudinal trends of all scales of diversity were similar in all groups. Alpha and gamma responded inversely to latitude whereas beta showed a high latitudinal fluctuation due to the high number of endemic species. Alpha and gamma showed a strong correlation in all groups. Beta diversity is an important component of the herpetofauna distribution patterns as a continuous source of species diversity throughout the region.

  17. Synergistic effects of interleukin-1beta, interleukin-6, and tumor necrosis factor-alpha: central monoamine, corticosterone, and behavioral variations.

    Science.gov (United States)

    Brebner, K; Hayley, S; Zacharko, R; Merali, Z; Anisman, H

    2000-06-01

    The proinflammatory cytokines interleukin-1beta (IL-1beta), IL-6, and tumor necrosis factor-alpha (TNF-alpha) influence neuroendocrine activity, promote central neurotransmitter alterations, and induce a constellation of symptoms collectively referred to as sickness behaviors. These cytokines may also elicit anxiety and anhedonia, and have been associated with psychological disturbances in humans. In the present investigation, systemic IL-1beta and TNF-alpha dose-dependently and synergistically disrupted consumption of a highly palatable food source (chocolate milk), possibly reflecting anorexia or anhedonia engendered by the treatments. As well, these cytokines synergistically increased plasma corticosterone levels. Although IL-1beta and TNF-alpha provoked variations of amine turnover in the hypothalamus, locus coeruleus, and central amygdala, synergistic effects were not evident in this respect. Nevertheless, in view of the central amine variations induced by the cytokines, it is suggested that immune activation may come to influence complex behavioral processes, as well as affective state. PMID:10788757

  18. A separation method of 0ν- and 2ν-events in double beta decay experiments with DCBA

    International Nuclear Information System (INIS)

    A detector called Drift Chamber Beta-ray Analyzer (DCBA) will provide momentum information of each β-ray in double beta decay. The DCBA is expected to have good capabilities for particle identification, detection efficiency, background elimination and decay-source integration. Under the assumption of mass mechanism dominance in neutrinoless double beta decay, a simulation study shows that a combination method using both sum and single-energy distributions of double beta decay events can separate 0ν- and 2ν-events down to 0.05 eV of the effective neutrino mass with the help of a calculated nuclear matrix element, even though the DCBA has relatively poor energy resolution

  19. Dependência energética e angular de materiais termoluminescentes para monitoração beta Energy and angular dependence of thermoluminescent materials to beta monitoring

    Directory of Open Access Journals (Sweden)

    Sonia Garcia Pereira Cecatti

    2006-12-01

    Full Text Available As dependências energética e angular de diferentes materiais termoluminescentes foram estudadas com o objetivo de verificar que tipo de detector seria o mais adequado para a monitoração de trabalhadores envolvidos com a radiação beta. Três tipos de pastilhas de CaSO4:Dy + teflon foram estudados. A dependência energética foi verificada usando-se fontes padrões de radiação beta (147Pm, 204Tl e 90Sr+90Y. A dependência angular foi verificada irradiando-se as amostras com feixes de radiação beta, variando-se o ângulo de incidência entre 0° e 90°. Os dosímetros de CaSO4:Dy + teflon + 10% C mostram-se os mais adequados para uso na monitoração de trabalhadores expostos à radiação beta, em relação às características estudadas.Energy and angular dependences of different thermoluminescent materials were studied with the objective to verify which type of detector would be the most appropriate for beta monitoring of workers. Three types of CaSO4:Dy + teflon pellets were studied. The energy dependence was evaluated using standard beta radiation sources (147Pm, 204Tl and 90Sr+90Y. For the angular dependence study, the pellets were exposed to beta radiation of the 90Sr+90Y source, varying the incidence angle between 0° and 90°. In relation to the studied characteristics, the CaSO4:Dy + 10% C dosimeters were the most adequate for use in beta monitoring of workers.

  20. Closed-form expressions for moments of a class of beta generalized distributions

    OpenAIRE

    Cordeiro, Gauss M.; Nadarajah, Saralees

    2011-01-01

    For the first time, we derive explicit closed-form expressions for moments of some beta generalized distributions including the beta gamma, beta normal, beta beta, beta Student t and beta F distributions. These expressions are given as infinite weighted sums of well-known special functions for which numerical routines for computation are available.

  1. Neutrinoless double beta decay from lattice QCD

    CERN Document Server

    Nicholson, Amy; Chang, Chia Cheng; Clark, M A; Joo, Balint; Kurth, Thorsten; Rinaldi, Enrico; Tiburzi, Brian; Vranas, Pavlos; Walker-Loud, Andre

    2016-01-01

    While the discovery of non-zero neutrino masses is one of the most important accomplishments by physicists in the past century, it is still unknown how and in what form these masses arise. Lepton number-violating neutrinoless double beta decay is a natural consequence of Majorana neutrinos and many BSM theories, and many experimental efforts are involved in the search for these processes. Understanding how neutrinoless double beta decay would manifest in nuclear environments is key for understanding any observed signals. In these proceedings we present an overview of a set of one- and two-body matrix elements relevant for experimental searches for neutrinoless double beta decay, describe the role of lattice QCD calculations, and present preliminary lattice QCD results.

  2. Calibration of beta dosimeter and personal dosimeter

    International Nuclear Information System (INIS)

    This paper introduces ISO standard ISO 6980 which prepared especially for the calibration of beta dosimeter and personal dosimeter. The standard has three aspects including method of production of reference beta particle radiations, calibration fundamentals related to basic quantities characterizing the radiation field, and calibration of area and personal dosemters and the determination of their response as a function of beta radiation energy and angle of incidence. Here particular emphasis is placed on the determination of basic quantity of tissue absorbed dose at a depth of 0.07 mm in the tissue slab phantom and calibration procedure by mean of the calibration quantity of directional dose equivalent H'(0.07, Ω) and personal dose equivalent Hp (0.07, Ω). Finally, combined standard uncertainty for the determination of absorbed dose rate and component uncertainties of calibration is given as examples. (authors)

  3. Tevatron B0 low beta tuning report

    International Nuclear Information System (INIS)

    A detailed study of the low beta insertion for the B0 experimental area has been carried out and is described below. This insertion is similar to the Type C low beta previously report, anti p Note 169, although some changes have been made to the quadrupole lengths and positions. This insertion is designated Type E. The purpose of the study was to see if it is possible to turn the insertion on in a smooth and continuous manner and tune the insertion to a value of β* of less than one meter while maintaining the overall tune of the j Tevatron to a constant value. This was found to be possible. An examination of chromaticity corrections for the Tevatron with the low beta insertion on in various configurations was also undertaken

  4. BETASCAN: probable beta-amyloids identified by pairwise probabilistic analysis.

    Directory of Open Access Journals (Sweden)

    Allen W Bryan

    2009-03-01

    Full Text Available Amyloids and prion proteins are clinically and biologically important beta-structures, whose supersecondary structures are difficult to determine by standard experimental or computational means. In addition, significant conformational heterogeneity is known or suspected to exist in many amyloid fibrils. Recent work has indicated the utility of pairwise probabilistic statistics in beta-structure prediction. We develop here a new strategy for beta-structure prediction, emphasizing the determination of beta-strands and pairs of beta-strands as fundamental units of beta-structure. Our program, BETASCAN, calculates likelihood scores for potential beta-strands and strand-pairs based on correlations observed in parallel beta-sheets. The program then determines the strands and pairs with the greatest local likelihood for all of the sequence's potential beta-structures. BETASCAN suggests multiple alternate folding patterns and assigns relative a priori probabilities based solely on amino acid sequence, probability tables, and pre-chosen parameters. The algorithm compares favorably with the results of previous algorithms (BETAPRO, PASTA, SALSA, TANGO, and Zyggregator in beta-structure prediction and amyloid propensity prediction. Accurate prediction is demonstrated for experimentally determined amyloid beta-structures, for a set of known beta-aggregates, and for the parallel beta-strands of beta-helices, amyloid-like globular proteins. BETASCAN is able both to detect beta-strands with higher sensitivity and to detect the edges of beta-strands in a richly beta-like sequence. For two proteins (Abeta and Het-s, there exist multiple sets of experimental data implying contradictory structures; BETASCAN is able to detect each competing structure as a potential structure variant. The ability to correlate multiple alternate beta-structures to experiment opens the possibility of computational investigation of prion strains and structural heterogeneity of amyloid

  5. High beta and electron dose from 192Ir: implications for 'gamma' intravascular brachytherapy

    International Nuclear Information System (INIS)

    Purpose: Trains of multiple 192Ir seeds are used in many clinical trials for intravascular brachytherapy. 192Ir source is commonly considered as a gamma emitter, despite the understanding that this radionuclide also emits a wide range of electron and beta energies, with a similar range of energy. The high dose from betas and electrons in the submillimeter range due to unsealed ends of seed sources should be precisely quantified to fully understand the backdrop for complications associated with 192Ir coronary artery brachytherapy. Methods and Materials: Monte Carlo simulations (MCNP4C code) were performed for a model 5-seed 192Ir train used in SCRIPPS, GAMMA, and the Washington Radiation for In-Stent Restenosis (WRIST) randomized clinical trials. A stack of radiochromic films was also used to measure the dose distributions for an actual 6-seed train. Results: In the submillimeter range very close to the source, Monte Carlo results show that betas and electrons deposit a higher dose than 192Ir photons (gamma and X-rays) over the interseed gap. A high luminal dose from the combined effects of betas, electrons, and photons emitted from 192Ir can be deposited, particularly between seeds. When prescribing 15 Gy at 2 mm, the combined dose can be as high as 160 Gy at 0.5 mm. Different peak doses near the interseed gaps were noted, which may be due to variability of seed-end surfaces and nonuniformity of seed activity within a real multiseed train. Dose-volume histograms (DVH) of lumen surfaces were evaluated for an eccentric seed train. The DVH parameters indicating the extent of hot spots in the lumen wall, DV10, DV5, DV2, and DV1 (dose received by 10, 5, 2, 1% respectively of the total lumen surface), can be as high as 55, 76, 81, and 155 Gy for a lumen with 3-mm diameter, and 75, 80, 110, and 158 Gy for a narrow 2-mm lumen. Conclusion: 192Ir multiple seed trains used in the SCRIPPS, GAMMA, and WRIST trials can deposit a very high dose to the luminal wall. A particularly

  6. beta2-Agonists at the Olympic Games.

    Science.gov (United States)

    Fitch, Kenneth D

    2006-01-01

    The different approaches that the International Olympic Committee (IOC) had adopted to beta2-agonists and the implications for athletes are reviewed by a former Olympic team physician who later became a member of the Medical Commission of the IOC (IOC-MC). Steadily increasing knowledge of the effects of inhaled beta2-agonists on health, is concerned with the fact that oral beta2-agonists may be anabolic, and rapid increased use of inhaled beta2-agonists by elite athletes has contributed to the changes to the IOC rules. Since 2001, the necessity for athletes to meet IOC criteria (i.e., that they have asthma and/or exercise-induced asthma [EIA]) has resulted in improved management of athletes. The prevalence of beta2-agonist use by athletes mirrors the known prevalence of asthma symptoms in each country, although athletes in endurance events have the highest prevalence. The age-of-onset of asthma/EIA in elite winter athletes may be atypical. Of the 193 athletes at the 2006 Winter Olympics who met th IOC's criteria, only 32.1% had childhood asthma and 48.7% of athletes reported onset at age 20 yr or older. These findings lead to speculation that years of intense endurance training may be a causative factor in bronchial hyperreactivity. The distinction between oral (prohibited in sports) and inhaled salbutamol is possible, but athletes must be warned that excessive use of inhaled salbutamol can lead to urinary concentrations similar to those observed after oral administration. This article provides justification that athletes should provide evidence of asthma or EIA before being permitted to use inhaled beta2-agonists. PMID:17085798

  7. Reduced beta band connectivity during number estimation in autism

    Directory of Open Access Journals (Sweden)

    Katrin A. Bangel

    2014-01-01

    Full Text Available Recent evidence suggests that disruption of integrative processes in sensation and perception may play a critical role in cognitive and behavioural atypicalities characteristic of ASD. In line with this, ASD is associated with altered structural and functional brain connectivity and atypical patterns of inter-regional communication which have been proposed to contribute to cognitive difficulties prevalent in this group. The present MEG study used atlas-guided source space analysis of inter-regional phase synchronization in ASD participants, as well as matched typically developing controls, during a dot number estimation task. This task included stimuli with globally integrated forms (animal shapes as well as randomly-shaped stimuli which lacked a coherent global pattern. Early task-dependent increases in inter-regional phase synchrony in theta, alpha and beta frequency bands were observed. Reduced long-range beta-band phase synchronization was found in participants with ASD at 70–145 ms during presentation of globally coherent dot patterns. This early reduction in task-dependent inter-regional connectivity encompassed numerous areas including occipital, parietal, temporal, and frontal lobe regions. These results provide the first evidence for inter-regional phase synchronization during numerosity estimation, as well as its alteration in ASD, and suggest that problems with communication among brain areas may contribute to difficulties with integrative processes relevant to extraction of meaningful ‘Gestalt’ features in this population.

  8. Characterization of beta radiation fields using radiochromic films

    International Nuclear Information System (INIS)

    The objective of this work was to study the response of radiochromic films for beta radiation fields in terms of absorbed dose. The reliability of the EBT model Gafchromic radiochromic film was studied. A 9800 XL model Microtek, transmission scanner, a 369 model X-Rite optical densitometer and a Mini 1240 Shimadzu UV spectrophotometer were used for measurement comparisons. Calibration of the three systems was done with irradiated samples of radiochromic films with 0.1; 0.3; 0.5; 0.8; 1.0; 1.5; 2.0; 2.5; 3.0; 3.5; 4.5 e 5.0 Gy in beta radiation field from a Sr-90/Y-90 source. Calibration was performed by establishing a correlation between the absorbed dose values and the corresponding radiochromic responses. Results showed significant differences in the absorbed dose values obtained with the three methods. Absorbed dose values showed errors from 0.6 to 4.4%, 0.3 to 31.8% and 0.2 to 47.3% for the Microtek scanner, the X-Rite Densitometer and the Shimadzu spectrophotometer, respectively. Due to the easy acquisition and use for absorbed dose measurements, the densitometer and the spectrophotometer showed to be suitable techniques to evaluate radiation dose in relatively homogeneous fields. In the case of inhomogeneous fields or for a two dimension mapping of radiation fields to identify anisotropies, the scanner technique is the most recommended. (author)

  9. 2MTF V. Cosmography, Beta, and the residual bulk flow

    CERN Document Server

    Springob, Christopher M; Staveley-Smith, Lister; Masters, Karen L; Macri, Lucas M; Koribalski, Baerbel S; Jones, D Heath; Jarrett, Tom H; Magoulas, Christina; Erdogdu, Pirin

    2015-01-01

    Using the Tully-Fisher relation, we derive peculiar velocities for the 2MASS Tully-Fisher Survey and describe the velocity field of the nearby Universe. We use adaptive kernel smoothing to map the velocity field, and compare it to reconstructions based on the redshift space galaxy distributions of the 2MASS Redshift Survey (2MRS) and the IRAS Point Source Catalog Redshift Survey (PSCz). With a standard $\\chi^2$ minimization fit to the models, we find that the PSCz model provides a better fit to the 2MTF velocity field data than does the 2MRS model, and provides a value of $\\beta$ in greater agreement with literature values. However, when we subtract away the monopole deviation in the velocity zeropoint between data and model, the 2MRS model also produces a value of $\\beta$ in agreement with literature values. We also calculate the `residual bulk flow': the component of the bulk flow not accounted for by the models. This is $\\sim 250$ km/s when performing the standard fit, but drops to $\\sim 150$ km/s for both...

  10. Gestalt perception is associated with reduced parietal beta oscillations.

    Science.gov (United States)

    Zaretskaya, Natalia; Bartels, Andreas

    2015-05-15

    The ability to perceive composite objects as a whole is fundamental for visual perception in a complex and cluttered natural environment. This ability may be mediated by increased communication between neural representations of distinct object elements, and has been linked to increased synchronization of oscillatory brain activity in the gamma band. Previous studies of perceptual grouping either guided attention between local and global aspects of a given stimulus or manipulated its physical properties to achieve grouped and ungrouped perceptual conditions. In contrast to those studies, we fully matched the physical properties underlying global and local percepts using a bistable stimulus that causes the viewer to perceive either local motion of multiple elements or global motion of two illusory shapes without any external change. To test the synchronization hypothesis we recorded brain activity with EEG, while human participants viewed the stimulus and reported changes in their perception. In contrast to previous findings we show that power of the beta-band was lower during perception of global Gestalt than during that of local elements. Source localization places these differences in the posterior parietal cortex, overlapping with a site previously associated with both attention and Gestalt perception. These findings reveal a role of parietal beta-band activity in internally, rather than externally or attention-driven processes of Gestalt perception. They also add to the growing evidence for shared neural substrates of attention and Gestalt perception, both being linked to parietal cortex. PMID:25731988

  11. Total absorption study of beta decays relevant for nuclear applications

    International Nuclear Information System (INIS)

    In this contribution we will present an overview of recent studies of the beta decay of nuclei relevant for the calculation of the decay heat in nuclear reactors as a continuation of the work presented in (1). The measurements are performed using the best available technique to detect the beta feeding probability, the total absorption technique (TAS). In our studies we have combined the TAS technique with the use of a Penning Trap (JYFLTRAP, Univ. of Jyvaeskylae) as a high-resolution isobaric separator in order to guarantee high purity of the sources. A brief summary of the latest results of the measurements using a new segmented total absorption spectrometer, the faced challenges depending of the particular nuclei as well as new developments of the techniques of analysis will be discussed. The impact of the measurements on summation calculations of the decay heat in reactors, and in possible non-proliferation applications will be addressed. Future plans and the development of a new modular TAS detector (DTAS) for the DEcay SPECtroscopy (DESPCE) experiment at FAIR will also presented. (author)

  12. Beta/gamma test problems for ITS

    International Nuclear Information System (INIS)

    The Integrated Tiger Series of Coupled Electron/Photon Monte Carlo Transport Codes (ITS 3.0, PC Version) was used at Oak Ridge National Laboratory (ORNL) to compare with and extend the experimental findings of the beta/gamma response of selected health physics instruments. In order to assure that ITS gives correct results, several beta/gamma problems have been tested. ITS was used to simulate these problems numerically, and results for each were compared to the problem's experimental or analytical results. ITS successfully predicted the experimental or analytical results of all tested problems within the statistical uncertainty inherent in the Monte Carlo method

  13. Double-Beta Decay at TUNL

    Science.gov (United States)

    Kidd, Mary

    2007-10-01

    Studying double-beta decay at Triangle Universities Nuclear Laboratory (TUNL) is perhaps one of the most promising ways to pinpoint the neutrino mass. What they do not mention is that to study double-beta decay, you probably have to become a certified miner, and if you have a fear of goats, you should stay away. In this talk, I will tell you some of my experiences as a TUNL graduate student, and how I am now nearly qualified for a job in the mining industry.

  14. Microscopic calculations for rare beta decays

    OpenAIRE

    Mustonen, Mika

    2010-01-01

    In this thesis consisting of six publications and an overview part, three cases of rare beta decays are studied using microscopic nuclear models. Firstly, the half-lives and electron spectra of 113Cd and 115In fourth-forbidden nonunique ground-state-to-ground-state beta decays are studied using two closely related nuclear models: The microscopic quasiparticle-phonon model (MQPM) and the proton-neutron MQPM (pnMQPM), which has been developed as a part of this thesis work. Our...

  15. Nuclear beta decay after Les Houches

    International Nuclear Information System (INIS)

    Wilkinson's 1977 Les Houches lectures summarized in detail how nuclear beta decay can be used to investigate fundamental nuclear phenomena and the achievements of this utilization up to that time. In this short talk the subsequent activity is briefly summarized and one area of high activity, namely first-forbidden beta decay, is singled out for more lengthy discussion. Specifically, the subject of interest is the very large meson exchange contribution to the time-like component of the axial current and the efforts to isolate this enhancement by means of careful shell-model calculations. 19 refs., 4 figs., 2 tabs

  16. Why search for double beta decay?

    International Nuclear Information System (INIS)

    Searching for neutrinoless double beta decay is the only known practical method for trying to determine whether neutrinos are their own antiparticles. The theoretical motivation for supposing that they may indeed be their own antiparticles is described. The reason that it is so difficult to ascertain experimentally whether they are or are not is explained, as is the special sensitivity of neutrinoless double beta decay. The potential implications of the observation of this reaction for neutrino mass and for the physics of neutrinos is discussed

  17. Helicity and nuclear $\\beta$ decay correlations

    CERN Document Server

    Hong, Ran; García, Alejandro

    2016-01-01

    We present simple derivations of nuclear $\\beta$-decay correlations with an emphasis on the special role of helicity. This provides a good opportunity to teach students about helicity and chirality in particle physics through exercises using simple aspects of quantum mechanics. In addition, this paper serves as an introduction to nuclear $\\beta$-decay correlations from both a theoretical and experimental vantage. This article can be used to introduce students to ongoing experiments searching for hints of new physics in the low-energy precision frontier.

  18. Card controlled beta backscatter thickness measuring instrument

    International Nuclear Information System (INIS)

    An improved beta backscatter instrument for the nondestructive measurement of the thickness of thin coatings on a substrate is described. Included therein is the utilization of a bank of memory stored data representative of isotope, substrate, coating material and thickness range characteristics in association with a control card having predetermined indicia thereon selectively representative of a particular isotope, substrate material, coating material and thickness range for conditioning electronic circuit means by memory stored data selected in accord with the predetermined indicia on a control card for converting backscattered beta particle counts into indicia of coating thickness

  19. Supermultiplet of $\\beta-$deformations from twistors

    CERN Document Server

    Milián, Segundo P

    2016-01-01

    We consider the supermultiplet of linearized beta-deformation of $\\mathcal{N}=4$ Super Yang-Mills(SYM). It was previously studied on the gravitational side. We study the supermultiplet of beta-deformations on the field theory side and we compare two finite-dimensional representations of $psl(4|4,\\bf{R})$ algebra. We show that they are related by an intertwining operator. We develop a twistor-based approach which could be useful for studying other finite-dimensional and nonunitary representations in AdS/CFT correspondence.

  20. Symmetry violations in nuclear and neutron $\\beta$ decay

    CERN Document Server

    Vos, K K; Timmermans, R G E

    2015-01-01

    The role of $\\beta$ decay as a low-energy probe of physics beyond the Standard Model is reviewed. Traditional searches for deviations from the Standard Model structure of the weak interaction in $\\beta$ decay are discussed in the light of constraints from the LHC and the neutrino mass. Limits on the violation of time-reversal symmetry in $\\beta$ decay are compared to the strong constraints from electric dipole moments. Novel searches for Lorentz symmetry breaking in the weak interaction in $\\beta$ decay are also included, where we discuss the unique sensitivity of $\\beta$ decay to test Lorentz invariance. We end with a roadmap for future $\\beta$-decay experiments.

  1. Source Water Protection Contaminant Sources

    Data.gov (United States)

    Iowa State University GIS Support and Research Facility — Simplified aggregation of potential contaminant sources used for Source Water Assessment and Protection. The data is derived from IDNR, IDALS, and US EPA program...

  2. Molecular and chemical comparison of beta/sub 2/ and beta/sub 2/ adrenergic receptors

    Energy Technology Data Exchange (ETDEWEB)

    Shorr, R.G.L.; Gotlib, L.; Varrichio, A.; Strohsacker, M.; Minnich, M.; Crooke, S.T.

    1986-05-01

    Beta-adrenergic receptor proteins of 55,000M/sub r/ and 45,000M/sub r/ have been purified from rabbit lung, guinea pig lung, bovine lung and turkey red blood cell plasma membranes by affinity chromatography, size exclusion high performance liquid chromatography and preparative SDS polyacrylamide gel electrophoresis. Each purified receptor was characterized with agonists and selective antagonists in ligand binding competition experiments with (/sup 125/I) cyanopindolol as being of the ..beta../sub 1/ or ..beta../sub 2/ adrenergic receptor subclass. Purified rabbit lung, guinea pig lung and bovine lung were all found to be of the ..beta../sub 2/ receptor subclass. Purified turkey RBC receptor was of the ..beta../sub 1/ subclass. When compared by molecular weight, each of the receptor proteins was found to comigrate on SDS polyacylamide gels with its counterpart from the additional tissues. When the proteins were compared by amino acid composition similar results were obtained for each of the receptors. These results suggest significant levels of sequence homology between the avian ..beta../sub 1/ adrenergic receptor and the mammalian ..beta../sub 2/ adrenergic receptor preparations.

  3. Human liver alcohol dehydrogenase. 1. The primary structure of the beta 1 beta 1 isoenzyme.

    Science.gov (United States)

    Hempel, J; Bühler, R; Kaiser, R; Holmquist, B; de Zalenski, C; von Wartburg, J P; Vallee, B; Jörnvall, H

    1984-12-17

    Determination of the amino acid sequence of the beta 1 subunit from the class I (pyrazole-sensitive) human liver alcohol dehydrogenase isoenzyme beta 1 beta 1 revealed a 373-residue structure differing at 48 positions (including a gap) from that of the subunit of the well studied horse liver alcohol dehydrogenase EE isoenzyme. The structure deduced is compatible with known differences in composition, ultraviolet absorbance, electrophoretic mobility and catalytic properties between the horse and human enzymes. All zinc-liganding residues of the horse E subunit are strictly conserved in the human beta 1 subunit, despite an earlier report of a mutation involving Cys-46. This residue therefore remains conserved in all known alcohol dehydrogenase structures. However, the total cysteine content of the beta 1 structure is raised from 14 in the subunit of the horse enzyme to 15 by a Tyr----Cys exchange. Most exchanges are on the surface of the molecule and of a well conserved nature. Substitutions close to the catalytic centre are of interest to explain the altered substrate specificity and different catalytic activity of the beta 1 homodimer. Functionally, a Ser----Thr exchange at position 48 appears to be of special importance, since Thr-48 in beta 1 instead of Ser-48 in the horse enzyme can restrict available space. Four other substitutions also line the active-site pocket, and appear to constitute partly compensated exchanges. PMID:6391920

  4. Use of multi-element TL dosimeters for beta and mixed beta/gamma personnel monitoring

    International Nuclear Information System (INIS)

    Applied experience as well as theoretical considerations make it clear that traditional two-element TL dosimeters are not adequate for use in personnel dosimetry involving beta radiation fields. The principal shortcoming of such dosimeters is that the TL element measuring the beta dose normally under responds, and the readings of such elements must be multiplied by a correction factor, called the beta factor, to obtain the dose. The beta factor, however, is not a constant but varies with variations in the beta spectrum incident on the dosimeter. Experimental tests carried out using a number of multi-element TL dosimeter designs have shown that the element readouts can be used in conjunction with a suitable algorithm to determine a suitable beta factor for use under a variety of irradiation conditions. The precision attainable in calculating the beta factor in this manner depends on a number of dosimeter design parameters and is often quite poor unless special care is exercised both in the design of the dosimeter and also in the operation of the readout system

  5. Nuclear Matrix Elements for the $\\beta\\beta$ Decay of the $^{76}$Ge

    CERN Document Server

    Brown, B A; Horoi, M

    2015-01-01

    The nuclear matrix elements for two-neutrino double-beta (2 n$\\beta\\beta$ ) and zero-neutrino double-beta (0 n$\\beta\\beta$) decay of 76 Ge are evaluated in terms of the configuration interaction (CI), quasiparticle random phase approximation (QRPA) and interacting boson model (IBM) methods. We show that the decomposition of the matrix elements in terms of interemediate states in 74 Ge is dominated by ground state of this nucleus. We consider corrections to the CI results that arise from configurations admixtures involving orbitals out-side of the CI configuration space by using results from QRPA, many-body-perturbation theory, and the connections to related observables. The CI two-neutrino matrix element is reduced due to the inclusion of spin-orbit partners, and to many-body correlations connected with Gamow-Teller beta decay. The CI zero-neutrino matrix element for the heavy neutrino is enhanced due to particle-particle correlations that are connected with the odd-even oscillations in the nuclear masse...

  6. Design of a self-triggered liquid xenon drift chamber for double-beta decay experiments

    International Nuclear Information System (INIS)

    Nuclear double-beta decay is one of the rarest processes in nature with the half life of 1019 - 1024 years. Such process takes place only when a nucleus cannot undergo ordinary beta decay due to energy conservation, or the very strong suppression of energetically allowed transition exists. This process proceeds through the channels of standard second order weak decay (two neutrinos double-beta decay) and lepton number nonconserving, neutrinoless double-beta decay. An isotope of 136Xe possesses attractive properties for the studies on the nuclei subjected to nutrinoless mode. Gaseous or liquid xenon is an excellent working medium for drift chambers, and it can act as both source and detector providing so called active source technique of experiment. In order to search for the neutrinoless mode of 136Xe, the liquid xenon drift chamber was designed, which is composed of three electrodes and four photomultipliers. This drift chamber is described. Th gas handling and vacuum system consisting of a xenon gas purifier, a high vacuum pumping facility and gas storage reservoirs is explained. Event identification, charge division method, the estimation of signal rate and the present state of this study are reported. (K.I.)

  7. Segmented Ge detector rejection of internal beta activity produced by neutron irradiation

    Science.gov (United States)

    Varnell, L. S.; Callas, J. L.; Mahoney, W. A.; Pehl, R. H.; Landis, D. A.

    1991-01-01

    Future Ge spectrometers flown in space to observe cosmic gamma-ray sources will incorporate segmented detectors to reduce the background from radioactivity produced by energetic particle reactions. To demonstrate the effectiveness of a segmented Ge detector in rejecting background events due to the beta decay of internal radioactivity, a laboratory experiment has been carried out in which radioactivity was produced in the detector by neutron irradiation. A Cf-252 source of neutrons was used to produce, by neutron capture on Ge-74 (36.5 percent of natural Ge) in the detector itself, Ge-75 (t sub 1/2 = 82.78 min), which decays by beta emission with a maximum electron kinetic energy of 1188 keV. By requiring that an ionizing event deposit energy in two or more of the five segments of the detector, each about 1-cm thick, the beta particles, which have a range of about 1-mm, are rejected, while most external gamma rays incident on the detector are counted. Analysis of this experiment indicates that over 85 percent of the beta events from the decay of Ge-75 are rejected, which is in good agreement with Monte Carlo calculations.

  8. Alpha and beta particle induced scintillations in liquid and solid neon

    CERN Document Server

    Michniak, R A; McKinsey, D N; Doyle, J M

    2002-01-01

    Scintillations induced by alpha and beta particles in liquid and solid neon are studied and their light yield measured. Charged particle scintillation in neon is primarily in the extreme ultraviolet (EUV). We detect this EUV light by converting it to blue using a wavelength shifting fluor and detecting the blue light with a photomultiplier tube. It is observed that liquid neon is a somewhat less-efficient scintillator than liquid helium for both alpha and beta radiation while the light yield in solid neon is greater than in liquid helium. Based on our measurements of the relative light yields of liquid and solid neon to liquid helium whose absolute light yield has previously been determined, we find that an alpha source in liquid neon produces up to 5900 photons per MeV while a beta source produces up to 7400 photons per MeV. In solid neon, we find that an alpha particle produces up to 9300 photons per MeV while a beta particle produces up to 17,000 photons per MeV. We observe a significant dependence of the ...

  9. Absolutely connected sets of standard radiation sources for dissemination of the activity unit

    International Nuclear Information System (INIS)

    Sealed gamma sources and plane beta sources to be used as reference standards have been produced in such a way that in connecting measurements certain corrections have been avoided (e.g. self-absorption) or can be eliminated (e.g. backscattering). The production of the radiation sources and the technique of absolute connection to the primary standard of the activity unit are described for one set of gamma and beta radiation sources each, and a survey of the standard radiation source sets available is given, considering nuclides, type of source, activity and measuring accuracy. (author)

  10. Improved estimate of the cross section for inverse beta decay

    CERN Document Server

    Ankowski, Artur M

    2016-01-01

    The hypothesis of the conserved vector current, relating the vector weak and isovector electromagnetic currents, plays a fundamental role in quantitative description of neutrino interactions. Despite being experimentally confirmed with great precision, it is not fully implemented in existing calculations of the cross section for inverse beta decay, the dominant mechanism of antineutrino scattering at energies below a few tens of MeV. In this article, I estimate the corresponding cross section and its uncertainty, ensuring conservation of the vector current. While converging to previous calculations at energies of several MeV, the obtained result is appreciably lower and predicts more directional positron production near the reaction threshold. These findings suggest that in the current estimate of the flux of geologically produced antineutrinos the 232Th and 238U components may be underestimated by 6.1 and 3.7%, respectively. The proposed search for light sterile neutrinos using a 144Ce--144Pr source is predi...

  11. An experimental investigation of double beta decay of 100Mo

    International Nuclear Information System (INIS)

    New limits on half-lives for several double beta decay modes of 100Mo were obtained with a novel experimental system which included thin source films interleaved with a coaxial array of windowless silicon detectors. Segmentation and timing information allowed backgrounds originating in the films to be studied in some detail. Dummy films containing 96Mo were used to assess remaining backgrounds. With 0.1 mole years of 100Mo data collected, the lower half-life limits at 90% confidence were 2.7 /times/ 1018 years for decay via the two-neutrino mode, 5.2 /times/1019 years for decay with the emission of a Majoron, and 1.6 /times/ 1020 years and 2.2 /times/ 1021 years for neutrinoless 0+ → 2+ and 0+ → 0+ transitions, respectively. 50 refs., 38 figs., 11 tabs

  12. Effects of beta/gamma radiation on nuclear waste glasses

    International Nuclear Information System (INIS)

    A key challenge in the disposal of high-level nuclear waste (HLW) in glass waste forms is the development of models of long-term performance based on sound scientific understanding of relevant phenomena. Beta decay of fission products is one source of radiation that can impact the performance of HLW glasses through the interactions of the emitted β-particles and g-rays with the atoms in the glass by ionization processes. Fused silica, alkali silicate glasses, alkali borosilicate glasses, and nuclear waste glasses are all susceptible to radiation effects from ionization. In simple glasses, defects (e.g., non-bridging oxygen and interstitial molecular oxygen) are observed experimentally. In more complex glasses, including nuclear waste glasses, similar defects are expected, and changes in microstructure, such as the formation of bubbles, have been reported. The current state of knowledge regarding the effects of β/γ radiation on the properties and microstructure of nuclear waste glasses are reviewed. (author)

  13. Beta-induced luminescence of some crystalline inorganic materials

    International Nuclear Information System (INIS)

    The beta-particle-induced luminescence spectra of a number of crystalline solids have been recorded using a single-photon -counting spectrometer in the search for high-stability u.v. light sources for use in analytical instrumentation. Of particular interest are the emissions from CaF2,sapphire and spinel, all of which produce useful emission intensities below 300 nm. The kinetic behaviour of the emissions from 1:1 and 1.8:1 spinels have been studied in some detail, and it is found that the noise level of the emitted light is significantly reduced by the 'smoothing' action of a long luminescence decay time. The results are consistent with the view that the spinel emission is associated with the recombination of electrons trapped on [AL]+sub(Mg) with holes trapped on [Mg]-sub(Al) centres. (author)

  14. Status of the Los Alamos tritium beta decay experiment

    International Nuclear Information System (INIS)

    The Los Alamos tritium experiment employs a gaseous tritium source and a magnetic spectrometer to determine the mass of the electron antineutrino from the shape of the tritium beta spectrum. Since publication of the first result from this apparatus (m/sub nu/ < 27 eV at 95% confidence), work has concentrated on improving the data rates. A 96-element Si microstrip array detector has been installed to replace the single proportional counter at the spectrometer focus, resulting in greatly increased efficiency. Measurements of the 1s photoionization spectrum of Kr now obviate the need for reliance on the theoretical shakeup and shakeoff spectrum of Kr in determining the spectrometer resolution. 19 refs., 3 figs

  15. Anomalous diffusion and transport beta limits in dense tokamak plasmas

    International Nuclear Information System (INIS)

    For tokamak plasmas which are sufficiently large and/or dense that the ionization source on axis may be neglected, particle balance is achieved by the inward diffusion due to the Ware pinch compensating the outward flow due to both neoclassical and anomalous diffusion. Insertion of measured data into the particle flux balance relation determines the anomalous particle diffusion coefficient Dsub(A); comparison of the results from a variety of tokamaks implies that the dominant dependence on machine and/or plasma parameters is Dsub(A) proportional to 1/n. Particle flux balance also implies an upper bound on the central value of βsub(e), the limiting value being obtained when the plasma parameters are chosen such that Dsub(A)<< Dsub(NEO). This limit has been computed for circular-cross-section tokamaks, and the results so obtained are of the same order as magnetohydrodynamic beta limits. (author)

  16. Neutron sources

    International Nuclear Information System (INIS)

    As neutron scattering experiments have grown more and more demanding with respect to resolution and quality, it became more and more necessary to include the neutron source itself in the design of an experimental setup. In this sense the generic representation of a neutron scattering arrangement includes the primary neutron source and the associated spectrum shifter (or moderator). In fact, the design of a modern neutron source will start from a set of users requirements and will proceed 'inwards' through a selection of the moderators (spectrum shifters) to the primary source best suited to meet these often conflicting needs. This paper aims at explaining the options source designers have to match the neutron source performance to the users' demands. (author)

  17. Positron sources

    International Nuclear Information System (INIS)

    A tentative survey of positron sources is given. Physical processes on which positron generation is based are indicated and analyzed. Explanation of the general features of electromagnetic interactions and nuclear β+ decay makes it possible to predict the yield and emittance for a given optical matching system between the positron source and the accelerator. Some kinds of matching systems commonly used - mainly working with solenoidal field - are studied and the acceptance volume calculated. Such knowledge is helpful in comparing different matching systems. Since for large machines, a significant distance exists between the positron source and the experimental facility, positron emittance has to be preserved during beam transfer over large distances and methods used for that purpose are indicated. Comparison of existing positron sources leads to extrapolation to sources for future linear colliders. Some new ideas associated with these sources are also presented. (orig.)

  18. National pattern for the realization of the unit of the dose speed absorbed in air for beta radiation. (Method: Ionometer, cavity of Bragg-Gray implemented in an extrapolation chamber with electrodes of variable separation, exposed to a field of beta radiation of {sup 90}Sr/{sup 90}Y); Patron Nacional para la realizacion de la unidad de la rapidez de dosis absorbida en aire para radiacion beta. (Metodo: Ionometrico, cavidad de Bragg-Gray implementada en una camara de extrapolacion con electrodos de separacion variable, expuesta a un campo de radiacion beta de {sup 90}Sr/{sup 90}Y)

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez R, M. T.; Morales P, J. R. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    2001-01-15

    From the year of 1987 the Department of Metrology of the ININ, in their Secondary Laboratory of Calibration Dosimetric, has a patron group of sources of radiation beta and an extrapolation chamber of electrodes of variable separation.Their objective is to carry out of the unit of the dose speed absorbed in air for radiation beta. It uses the ionometric method, cavity Bragg-Gray in the extrapolation chamber with which it counts. The services that offers are: i) it Calibration : Radioactive Fuentes of radiation beta, isotopes: {sup 90}Sr/{sup 90}Y; Ophthalmic applicators {sup 9}0{sup S}r/{sup 90}Y; Instruments for detection of beta radiation with to the radiological protection: Ionization chambers, Geiger-Muller, etc.; Personal Dosemeters. ii) Irradiation with beta radiation of materials to the investigation. (Author)

  19. Background discrimination in neutrinoless double beta decay search with $\\textrm{TeO}_{2}$ bolometers using Neganov-Luke amplified cryogenic light detectors

    CERN Document Server

    Willers, M; Giuliani, A; Gütlein, A; Münster, A; Lanfranchi, J -C; Oberauer, L; Potzel, W; Roth, S; Schönert, S; Sivers, M v; Wawoczny, S; Zöller, A

    2014-01-01

    We demonstrate that Neganov-Luke amplified cryogenic light detectors with Transition Edge Sensor read-out can be applied for the background suppression in cryogenic experiments searching for the neutrinoless double beta decay of $^{130}\\text{Te}$ with $\\text{TeO}_{2}$ based bolometers. Electron and gamma induced events can be discriminated from $\\alpha$ events by detecting the Cherenkov light produced by the $\\beta$ particles emitted in the decay. We use the Cherenkov light produced by events in the full energy peak of $^{208}\\text{Tl}$ and by events from a $^{147}\\text{Sm}$ source to show that at the Q-value of the neutrinoless double beta decay of $^{130}\\text{Te}$ ($Q_{\\beta \\beta} = 2.53 \\,\\text{MeV}$), a separation of $e^{-}/\\gamma$ events from $\\alpha$ events can be achieved on an event-by-event basis with practically no reduction in signal acceptance.

  20. Massaspectrometrische analyse van enkele beta-agonisten

    OpenAIRE

    Traag, W.A.; Kienhuis, P.G.M.; Tuinstra, L.G.M.T.; Bennekom, van, C.A.M.; Huf, F.A.

    1990-01-01

    Zes beta-agonisten (isoproterenol, clenbuterol, cimaterol, terbutaline, salbutamol en fenoterol) zijn als TMS-derivaten onderzocht op hun GeMS-eigenschappen in zowel de Electron Impact (EI) als positieve Chemische Ionisatie mode (Cl). Tevens is clenbuterol-hexyl onderzocht. Deze component is geschikt om als interne standaard te fungeren.

  1. Association behavior of native beta-lactoglobulin

    DEFF Research Database (Denmark)

    Verheul, M.; Pedersen, J.S.; Roefs, S.P.F.M.; Kruif, K.G. de

    1999-01-01

    samples were obtained. These functions provided information on the maximum size, the weight-averaged molecular mass, and the z-averaged radius of gyration oo the the beta-lactoglobulin particles. Al room temperature and pH values below 4 and above IZ the protein consists predominantly of monomers and...

  2. Herwig++ 2.0beta Release Note

    OpenAIRE

    Gieseke, Stefan; Grellscheid, D.; Ribon, Alberto; Richardson, P.; Seymour, Michael H.; Stephens, Phil; Webber, Bryan R

    2006-01-01

    A new release of the Monte Carlo program Herwig++ (version 2.0beta) is now available. The main new feature is the extension of the program to include simple hadron-hadron processes including the initial-state parton shower.

  3. Characterization of a Commercial Silicon Beta Cell

    Energy Technology Data Exchange (ETDEWEB)

    Foxe, Michael P. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hayes, James C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Mayer, Michael F. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); McIntyre, Justin I. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Sivels, Ciara B. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Suarez, Rey [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-03-31

    Silicon detectors are of interest for the verification of the Comprehensive Nuclear-Test-Ban Treaty (CTBT) due to their enhanced energy resolution compared to plastic scintillators beta cells. Previous work developing a figure-of-merit (FOM) for comparison of beta cells suggests that the minimum detectable activity (MDA) could be reduced by a factor of two to three with the use of silicon detectors. Silicon beta cells have been developed by CEA (France) and Lares Ltd. (Russia), with the PIPSBox developed by CEA being commercially available from Canberra for approximately $35k, but there is still uncertainty about the reproducibility of the capabilities in the field. PNNL is developing a high-resolution beta-gamma detector system in the shallow underground laboratory, which will utilize and characterize the operation of the PIPSBox detector. Throughout this report, we examine the capabilities of the PIPSBox as developed by CEA. The lessons learned through the testing and use of the PIPSBox will allow PNNL to strategically develop a silicon detector optimized to better suit the communities needs in the future.

  4. Nuclear physics issues in double beta decay

    International Nuclear Information System (INIS)

    A number of issues in double beta decay are discussed: shell model estimates of 2nu matrix elements, a sum rule for the double Gamow-Teller operator, a comparison of shell model and quasiparticle RPA results, Pontecorvo's Te ratio argument, neutrinoless ββ decay mediated by heavy neutrinos, and the structure of O+ states in Ge isotopes. 24 refs., 3 figs

  5. Average beta measurement in EXTRAP T1

    International Nuclear Information System (INIS)

    Beginning with the ideal MHD pressure balance equation, an expression for the average poloidal beta, ΒΘ, is derived. A method for unobtrusively measuring the quantities used to evaluate ΒΘ in Extrap T1 is described. The results if a series of measurements yielding ΒΘ as a function of externally applied toroidal field are presented. (author)

  6. Topical beta-Blockers and Mortality

    NARCIS (Netherlands)

    Muskens, Rogier P. H. M.; Wolfs, Roger C. W.; Wittenian, Jacqueline C. M.; Hofman, Albert; de Jong, Paulus T. V. M.; Stricker, Bruno H. C.; Jansonius, Nomdo M.

    2008-01-01

    Purpose: To study the associations between long-term and short-term use of topical beta-blockers and mortality. Design: Prospective population-based cohort study. Participants: To examine long-term effects, 3842 participants aged 55 years and older were recruited. To examine short-term effects, 484

  7. Redox Homeostasis in Pancreatic beta Cells

    Czech Academy of Sciences Publication Activity Database

    Ježek, Petr; Dlasková, Andrea; Plecitá-Hlavatá, Lydie

    2012-01-01

    Roč. 2012, č. 2012 (2012), s. 932838. ISSN 1942-0900 R&D Projects: GA ČR(CZ) GAP302/10/0346; GA ČR(CZ) GPP304/10/P204 Institutional support: RVO:67985823 Keywords : beta cells * reactive oxygen species homeostasis * mitochondria Subject RIV: FB - Endocrinology, Diabetology, Metabolism, Nutrition Impact factor: 3.393, year: 2012

  8. Semiconductor detectors and double beta decay

    International Nuclear Information System (INIS)

    The underlying theory of double beta decay is discussed as well as some experimental observations. A class of second generation 76Ge detector experiments is then discussed. The design and physics considerations involved in the system used by LBL are explained, particularly the means of rejecting background activity. 24 references, 18 figures, 3 tables

  9. Multiple nerve palsies in beta thalassaemia major.

    OpenAIRE

    Lamabadusuriya, S. P.

    1989-01-01

    A patient with beta thalassaemia major is described who developed a lower motor neurone facial nerve palsy on the left side, together with a phrenic nerve palsy on the same side, during the course of the illness. This complication has not been reported before in haemoglobinopathies.

  10. LHC dijet constraints on double beta decay

    CERN Document Server

    Helo, J C

    2015-01-01

    We use LHC dijet data to derive constraints on neutrinoless double beta decay. Upper limits on cross sections for the production of "exotic" resonances, such as a right-handed W boson or a diquark, can be converted into lower limits on the double beta decay half-life for fixed choices of other parameters. Constraints derived from run-I data are already surprisingly strong and complementary to results from searches using same-sign dileptons plus jets. For the case of the left-right symmetric model, in case no new resonance is found in future runs of the LHC and assuming $g_L=g_R$, we estimate a lower limit on the double beta decay half-live larger than $10^{27}$ ys can be derived from future dijet data, except in the window of relatively light right-handed neutrino masses in the range $0.5$ MeV to $50$ GeV. Part of this mass window will be tested in the upcoming SHiP experiment. We also discuss current and future limits on possible scalar diquark contributions to double beta decay that can be derived from dije...

  11. Double beta decay: A theoretical overview

    Energy Technology Data Exchange (ETDEWEB)

    Rosen, S.P.

    1988-01-01

    This paper reviews the theoretical possibility of double beta decay. The titles of the main sections of this paper are: Nuclear physics setting; Particle physics requirements; Kinematical features of the decay modes; Nuclear matrix elements; the Shell model and two-neutrino decay; Quasi-particle random phase approximation; and Future considerations. 18 refs., 7 tabs. (LSP)

  12. Frameshift mutation events in beta-glucosidases.

    Science.gov (United States)

    Rojas, Antonio; Garcia-Vallvé, Santiago; Montero, Miguel A; Arola, Lluís; Romeu, Antoni

    2003-09-18

    Compensated frameshift mutation is a modification of the reading frame of a gene that takes place by way of various molecular events. It appears to be a widespread event that is only observed when homologous amino acid and nucleodotide sequences are compared. To identify these mutation events, the sequence analysis rationale was based on the search for short regions that would have much lower degrees of conservation in protein, but not in DNA, in well-conserved beta-glucosidase families. We have restricted our study to a seed set of sequences of O-glycoside hydrolase families 1 and 3. We found compensated frameshift mutation in the family of 1 beta-glucosidases for the Erwinia herbicola, Cellulomonas fimi, and (non-cyanogenic) Trifolium repens gene sequences, and in the family of 3 beta-glucosidases for the Clostridium thermocellum and Clostridium stercorarium gene sequences. By computational treatment, the observed mutation events in the gene frameshifting sub-sequence have been neutralised. Each nucleotide insertion must be eliminated and each nucleotide deletion must be substituted by the symbol N (any nucleotide). When the frameshifting fragments of the amino acid sequences were substituted by the computationally neutralised subsequences, the beta-glucosidase alignments were improved. We also discuss the structural implications of the compensated frameshift mutations events. PMID:14527732

  13. Three loop QCD MOM beta-functions

    CERN Document Server

    Gracey, J A

    2011-01-01

    We present the full expressions for the QCD beta-function in the MOMggg, MOMq and MOMh renormalization schemes at three loops for an arbitrary colour group in the Landau gauge. The results for all three schemes are in very good agreement with the SU(3) numerical estimates provided by Chetyrkin and Seidensticker.

  14. Lepton nonconservation and double beta decay

    International Nuclear Information System (INIS)

    This paper reviews the status of double beta decay as a test of lepton number conservation. Present limits on the mass of a Majorana neutrino are in the range of 10 to 50 eV. Experiments now in progress should substantially improve these limits

  15. Association behavior of native beta-lactoglobulin

    DEFF Research Database (Denmark)

    Verheul, M.; Pedersen, J.S.; Roefs, S.P.F.M.;

    1999-01-01

    The association behavior of beta-lactoglobulin has been studied by small-angle neutron scattering as a function of protein concentration, temperature, pH, and NaCl concentration of the solution. By indirect Fourier transformation of the spectra, pair-distance distribution functions for the various...

  16. Long term prospects for double beta decay

    OpenAIRE

    Zuber, K.

    2010-01-01

    In rather general terms the long term perspective of double beta decay is discussed. All important experimental parameters are investigated as well as the status of nuclear matrix element issues. The link with other neutrino physics results and options to disentangle the underlying physics process are presented.

  17. Weak interaction studies from nuclear beta decay

    International Nuclear Information System (INIS)

    The studies performed at the theoretical nuclear physics division of the Laboratory of Nuclear Studies, Osaka University, are reported. Electron spin density and internal conversion process, nuclear excitation by electron transition, beta decay, weak charged current, and beta-ray angular distributions in oriented nuclei have been studied. The relative intensity of internal conversion electrons for the case in which the radial wave functions of orbital electrons are different for electron spin up and down was calculated. The calculated value was in good agreement with the experimental one. The nuclear excitation following the transition of orbital electrons was studied. The calculated probability of the nuclear excitation of Os189 was 1.4 x 10-7 in conformity with the experimental value 1.7 x 10-7. The second class current and other problems on beta-decay have been extensively studied, and described elsewhere. Concerning weak charged current, the effects of all induced terms, the time component of main axial vector, all partial waves of leptons, Coulomb correction for the electrons in finite size nuclei, and radiative correction were studied. The beta-ray angular distribution for the 1+ -- 0+ transition in oriented B12 and N12 was investigated. In this connection, investigation on the weak magnetism to include all higher order corrections for the evaluation of the spectral shape factors was performed. Other works carried out by the author and his collaborators are also explained. (Kato, T.)

  18. Plastic bronchitis in beta thalassemia minor

    OpenAIRE

    Makaresh Yadav; Sneha Tirpude; Joshi, Jyotsna M.

    2013-01-01

    Plastic bronchitis is a rare pulmonary disorder associated with various conditions like cystic fibrosis, asthma, pulmonary infection and characterized by formation and expectoration of cast which assumes the shape of the bronchial tree. We report a case of a 33-year-old woman with beta thalassemia minor who developed plastic bronchitis.

  19. Cell therapies for pancreatic beta-cell replenishment.

    Science.gov (United States)

    Okere, Bernard; Lucaccioni, Laura; Dominici, Massimo; Iughetti, Lorenzo

    2016-01-01

    The current treatment approach for type 1 diabetes is based on daily insulin injections, combined with blood glucose monitoring. However, administration of exogenous insulin fails to mimic the physiological activity of the islet, therefore diabetes often progresses with the development of serious complications such as kidney failure, retinopathy and vascular disease. Whole pancreas transplantation is associated with risks of major invasive surgery along with side effects of immunosuppressive therapy to avoid organ rejection. Replacement of pancreatic beta-cells would represent an ideal treatment that could overcome the above mentioned therapeutic hurdles. In this context, transplantation of islets of Langerhans is considered a less invasive procedure although long-term outcomes showed that only 10 % of the patients remained insulin independent five years after the transplant. Moreover, due to shortage of organs and the inability of islet to be expanded ex vivo, this therapy can be offered to a very limited number of patients. Over the past decade, cellular therapies have emerged as the new frontier of treatment of several diseases. Furthermore the advent of stem cells as renewable source of cell-substitutes to replenish the beta cell population, has blurred the hype on islet transplantation. Breakthrough cellular approaches aim to generate stem-cell-derived insulin producing cells, which could make diabetes cellular therapy available to millions. However, to date, stem cell therapy for diabetes is still in its early experimental stages. This review describes the most reliable sources of stem cells that have been developed to produce insulin and their most relevant experimental applications for the cure of diabetes. PMID:27400873

  20. Sources management

    International Nuclear Information System (INIS)

    Organized by the section of technical protection of the French society of radiation protection ( S.F.R.P.), these two days had for objective to review the evolution of the rule relative to the sources of ionising radiations 'sealed and unsealed radioactive sources, electric generators'. They addressed all the actors concerned by the implementation of the new regulatory system in the different sectors of activities ( research, medicine and industry): Authorities, manufacturers, and suppliers of sources, holders and users, bodies involved in the approval of sources, carriers. (N.C.)