WorldWideScience

Sample records for beta sources

  1. Dosimetry of {beta} extensive sources; Dosimetria de fuentes {beta} extensas

    Energy Technology Data Exchange (ETDEWEB)

    Rojas C, E.L.; Lallena R, A.M. [Departamento de Fisica Moderna, Universidad de Granada, E-18071 Granada (Spain)

    2002-07-01

    In this work, we have been studied, making use of the Penelope Monte Carlo simulation code, the dosimetry of {beta} extensive sources in situations of spherical geometry including interfaces. These configurations are of interest in the treatment of the called cranealfaringyomes of some synovia leisure of knee and other problems of interest in medical physics. Therefore, its application can be extended toward problems of another areas with similar geometric situation and beta sources. (Author)

  2. Beta-Excited Sources of Electromagnetic Radiation; Sources de rayonnements electromagnetiques excites par des particules beta; Vozbuzhdennye beta-chastitsami istochniki ehlektromagnitnogo izlucheniya; Fuentes de radiacion electromagnetica excitadas por particulas beta

    Energy Technology Data Exchange (ETDEWEB)

    Cameron, J F; Rhodes, J R [Physics Group, Isotope Research Division, (AERE), Wantage Research Laboratory, Wantage, Berks (United Kingdom)

    1962-01-15

    Beta-excited sources of electromagnetic radiation covering the energy region 1-200 keV and suitable for industrial use are described. H{sup 3}, Pm{sup 147}, Kr{sup 85}, Tl{sup 204} and (Sr+Y){sup 90} were chosen as sources of beta particles by the criteria of long half-life, low price, ready availability and high specific activity. The {beta}-excited sources have been designed on the basis of a compromise between practical source construction and the best theoretical efficiency in a given energy region. In their paper, the authors calculate the number of photons produced per beta particle and consider how the results must be corrected for self-absorption of the X-rays. In the calculations account is taken of both bremsstrahlung and characteristic {alpha}-radiation; optimum characteristic X-ray yield is achieved for targets with an atomic number between 40 and 60. ''Sandwich'' targets of 1-2 beta half-value thicknesses are found to give maximum photon-yields in the desired energy region. Al, Ag and Au are suitable from the manufacturing point of view as source coverings. They were also found to give satisfactory bremsstrahlung and X-ray yields and distribution for various energy regions in the range 1-200 keV when correctly combined with the above-mentioned D-emitters. Some energy spectra are given and absorption curves in Al and Fe are shown for the best source-target combinations. The difference between sources constructed of {beta}-emitters sandwiched between target foils and intimate source-target mixtures was found to be small. Tables are given as a guide to the best source to be used for a particular absorber thickness range. (author) [French] Les auteurs decrivent des sources de rayonnements electromagnetiques excites par des particules beta, couvrant une gamme d'energies allant de 1 a 200 keV et convenant aux usages industriels. Comme sources de particules beta on a choisi le tritium, le {sup 147}Pm, le {sup 85}Kr, le {sup 204}Tl et le {sup 90}(Sr+Y), en

  3. Construction of a high beta plasma source

    International Nuclear Information System (INIS)

    Naraghi, M.; Torabi-Fard, A.

    1976-02-01

    A high beta plasma source has been designed and constructed. This source will serve as a means of developing and exercising different diagnostic techniques as required for ALVAND I, linear theta pinch experiment. Also, it will serve to acquaint the technicians with some of the techniques and safety rules of high voltage and capacitor discharge experiments. The operating parameters of the theta pinch and Z-pinch preionization is presented and the program of diagnostic measurements on the high beta plasma source is discussed

  4. Source preparations for alpha and beta measurements

    Energy Technology Data Exchange (ETDEWEB)

    Holm, E. [Risoe National Lab., Roskilde (Denmark)

    2001-01-01

    Regarding alpha particle emitters subject for environmental studies, electrodeposition or co-precipitation as fluorides are the most common methods. For electro deposition stainless steel is generally used as cathode material but also other metals such as Ni, Ag, and Cu showed promising results. The use of other anode material than platinum, such as graphite should be investigated. For other purposes such as optimal resolution other more sophisticated methods are used but often resulting in poorer recovery. For beta particle emitters the type of detection system will decide the source preparation. Similar methods as for alpha particle emitters, electrodeposition or precipitation techniques can be used. Due to the continuous energy distribution of the beta pulse height distribution a high resolution is not required. Thicker sources from the precipitates or a stable isotopic carrier can be accepted but correction for absorption in the source must be done. (au)

  5. Dosimetry of beta sources utilized in nuclear medicine and biomedicine

    International Nuclear Information System (INIS)

    Bergoc, R.M.; Rivera, E.; Cricco, G.; Martin, G.; Cocca, C.; Caro, R.A.

    1998-01-01

    Full text: The use of high energy pure beta sources (i.e., 32 P= 1.71 MeV/des) is common in medicine (intratumoral therapy or treatment of non-malignant illness as restenosis) and in biochemistry (molecular biology). The external dosimetry of these sources offers some important points that must be considered: 1) beta particles emitted by the source are not monoenergetic; 2) the range (R 0 ) vary with the source energy and the Z of the absorber; 3) below an energy of 1 MeV, the specific ionization in the absorbent medium (air, water, lucite) increases as the beta energy (E β ) decreases; 4) the range of beta particles, R β , is independent from Z of the material, provided Z is low and the material has no hydrogen; in this case, the expression: R β δ 1 = R β δ 2 is valid; 5) the calculation of the external beta dosimetry must consider that since the used sources are not punctual there is self-absorption which should be taken into account. However, in the range of the fractions of activities for the above mentioned practices a theoretical model for punctual sources can be used; in this case, it is valid to use the expression: Dose Rate: = A (S/δ)E β e -S/δ δx /4 π d 2 , where: (S/δ) is the absorbent Mass Stopping Power and represents the loss of energy by unit mass thickness; it depends from E β and it is independent from Z; (δx) is the mass thickness of the absorber. By this way, e -S/δ δx is the attenuation of the beta particles flow. From the application of this formula it can be deduced that, for sources of 1 mCi of 32 P activities, as those employed in biochemistry, a small thickness of lucite is enough shield. When the source has higher activities, as those used in radiotherapy, the operator should take into account the regulations for a strict dosimetric control. These formulae allow a simplified calculation of the 32 P dosimetry of sources used in nuclear medicine and biomedical practices. (author) [es

  6. Procedure for the elaboration of extended sources beta and/or gamma emitting

    International Nuclear Information System (INIS)

    Tejera R, A.; Cortes P, A.; Becerril V, A.

    1991-12-01

    In the laboratory of radioactive standards they have been come manufacturing punctual sources gauged gamma emitting during several years. Before the demand of extended radioactive homogeneous sources of beta particles emitting, in particular with nuclides that are simultaneously gamma and beta emitting, it was designed a procedure for it elaboration based on the one that we use at the moment for the elaboration of the punctual gamma sources. This procedure consists on the integration of a compact group of this type of sources on a single extended support, sealed one of its faces with a film of transparent material in satisfactory grade to the beta particles. In this work this procedure is described and it is applied in the elaboration of two sources that its were requested by the Laguna Verde Central (CFE), one with area of 20 cm 2 and the other one of 100 cm 2 . The homogeneity, measure as the dispersion of the activities of the aliquot ones distributed in the active surfaces was inside 2%. The percentage of attenuation of the beta particles was also measured by the film (window) with the one that the sources were sealed. (Author)

  7. Automatic device for measuring {beta}-emitting sources: P.A.P.A. {beta}-meters; Dispositif automatique pour la mesure de sources emettrices de rayonnement {beta}: P.A.P.A. {beta} metres

    Energy Technology Data Exchange (ETDEWEB)

    Colomer, J; Valentin, M [Commissariat a l' Energie Atomique, Bruyeres-le-Chatel (France). Centre d' Etudes

    1969-07-01

    The apparatus described is designed for measuring {beta}-emitting elements by the absorption method; it is suitable for carrying out a large number of routine analyses. A mechanical device pushes an aluminium absorption set automatically between the source and the detector; the movement is programmed for cutting on and off by a transistorized electronic unit, with printing out and punching of the results on tape; then this can be mathematically processed by a computer (tracing of absorption spectra, extrapolation and calculation of the activity). The detector is either a {beta}-probe or a proportional counter with a specially designed loop. For routine measurements, the accuracy obtained, with all corrections made, is from 5 to 8 per cent; the reproducibility is about 2 per cent. (authors) [French] L'appareillage decrit est destine aux mesures des elements emetteurs {beta} par la methode d'absorption et il permet d'effectuer, en routine, un nombre important de mesures. Un ensemble mecanique effectue le passage automatique, sous vide primaire, d'un jeu d'absorption en aluminium entre la source et le detecteur, ce passage est programme en pre-temps ou pre-coup par un ensemble electronique a transistors, avec impression et perforation sur bandes des resultats des mesures pour traitement mathematique par un ordinateur (trace du spectre d'absorption, extrapolation et calcul d'activite). Le detecteur est soit une sonde {beta}, soit un compteur proportionnel a boucle specialement realise. Sur des mesures de routine, la precision obtenue, toutes corrections effectuees, est de 5 a 8 pour cent et la reproductibilite de l'ordre de 2 pour cent. (auteur)

  8. The genus Rhodosporidium: a potential source of beta-carotene.

    Science.gov (United States)

    de Miguel, T; Calo, P; Díaz, A; Villa, T G

    1997-03-01

    Four wild-type species of the genus Rhodosporidium have been studied as as possible sources for the industrial production of beta-carotene. HPLC-based studies showed that their carotenoid composition consisted of almost pure beta-carotene at concentrations ranging from 226 to 685 micrograms/g of dried yeast biomass. These results are consistent with those obtained by spectrophotometry at 480 nm.

  9. Guidelines for the calibration of low energy photon sources at beta-ray brachytherapy sources

    International Nuclear Information System (INIS)

    2000-01-01

    Kerma Rate. In this document the latter recommendation is adopted. Both of the quantities give the same numerical value for the source strength and differ only in the units they are expressed. The recommended dose calculation method is discussed further in the text. Sealed beta-ray sources for brachytherapy treatments have been in use for few decades already. An example is application of 90 Sr/ 90 Y planar sources for ophthalmic brachytherapy treatments. For these types of treatments, a precise dose distribution within the eye globe is needed. Modern diagnostic techniques permit the determination of all volumes of interest in the eye, i.e. tumor and critical structures such as optic disc and iris with a high precision. It is therefore of importance to optimize the treatment by limiting the dose to these critical structures. A relatively new and rapidly developing field in brachytherapy is the use of beta-ray sources for prevention of restenosis, i.e. re-closing of artery, following coronary and peripheral artery interventional procedures such as angioplasty, atherectomy and stent implantation. The dosimetry of beta-ray sources for therapeutic applications is particularly difficult due to the short distances involved, being at the millimeter range, and the high dose gradients at such short distances. Further difficulties are caused by the non-uniform distribution of activity in the source itself, causing a highly irregular dose distribution. The aim of this report is to recommend methods for calibration of low energy photon sources and beta-ray sources used in brachytherapy treatments and to propose suitable detectors for this purpose. Dose calculation methods are given both for the photon sources and beta-ray sources covered in this report. The present report has been developed in close collaboration with the ICRU Report Committee on this subject. The ICRU is planning to publish a report on the calibration of the type of sources discussed here. The present report is to

  10. Radioactive check sources for alpha and beta sensitive radiological instrumentation

    International Nuclear Information System (INIS)

    Barnett, J.M.; Kane, J.E. II.

    1994-06-01

    Since 1991, the Westinghouse Hanford Company has examined the construction and use of alpha and beta radioactive check sources for calibrating instruments and for performing response checks of instruments used for operational and environmental radiation detection. The purpose of using a radioactive check source is to characterize the response of a radiation monitoring instrument in the presence of radioactivity. To accurately calibrate the instrument and check its response, the check source used must emulate as closely as possible the actual physical and isotopic conditions being monitored. The isotope employed and the physical methods used to fabricate the check source (among other factors) determine instrument response. Although information from applicable national and international standards, journal articles, books, and government documents was considered, empirical data collected is most valuable when considering the type of source to use for a particular application. This paper presents source construction methods, use considerations, and standard recommendations. The results of a Hanford Site evaluation of several types of alpha and beta sources are also given

  11. The Technology and Applications of Large Fission Product Beta Sources; Technologie et applications des grandes sources beta de fission; Tekhnologiya i primenenie krupnykh istochnikov beta-izluchenij, ispuskaemykh produktami deleniya; Tecnologia y utilizacion de los productos de fision como fuentes de irradiacion beta de elevada intensidad

    Energy Technology Data Exchange (ETDEWEB)

    Silverman, Joseph [Radiation Applications Incorporated (United States)

    1960-07-15

    Beta emitters have not received consideration as large sources of radiation power because in the past, the radiation processes of interest have been based on particles with high penetration power; hence the great emphasis on gammas and artificially accelerated electrons. About four years ago, it became apparent that a broad field of potential applications involving surface radiation treatment was developing, e. g. surface modification of formed plastics by graft copolymerization and surface pasteurization of food. For these applications, penetration in depth is wasteful and potentially harmful. Also there are two other areas for which machine electrons were not well suited: radiation-induced chemical syntheses in pressure vessels, and certain types of free radical chain reactions for which the production rate per kilowatt decreases with the square root of the dose rate. Broad area beta sources showed obvious potential advantages in all these categories and, since they are available in good yield from the fission process, merited a careful re-appraisal. On the basics of these considerations an AEC sponsored study of the applications and technology of fission product beta sources was performed. The results indicate the following: 1. There are promising areas for commercial application of fission product beta emitters in the radiation processing field, particularly in the graft copolymerization modification of formed plastic surfaces and textiles. 2. Massive, rugged, inert, safe, inexpensive beta sources may be fabricated by suitable extensions of existing techniques. Source-bearing glass formulations show particular promise. 3. Beta absorption calculations indicate that extended sources can be designed with power utilization efficiencies as high as 20 per cent. Equations and curves describing dosage and beta utilization efficiency as a function of the geometry and composition of various source-target systems were developed. An experimental program is in progress to

  12. A new irradiated quartz for beta source calibration

    DEFF Research Database (Denmark)

    Hansen, Vicki; Murray, Andrew Sean; Buylaert, Jan-Pieter

    2015-01-01

    For luminescence dating to be an accurate absolute dating technique it is very important that we are able to deliver absolutely known radiation doses in the laboratory. This is normally done using a radiation source (alpha, beta, X-ray) calibrated against an absolutely known reference source. Man...... doses from a standardised gamma source to in-built irradiation sources....... from south-western Denmark (Rømø). Two grain sizes (4-11μm and 180-250μm) have been examined in detail. These were pre-treated (annealed, dosed and annealed again) to sensitise and stabilise the luminescence signals before being given an absolutely known gamma dose from a point 137Cs source in scatter...

  13. Elaboration of supports for beta emitting sources (with vyns); Elaboracion de soportes para fuentes emisoras beta (con vyns)

    Energy Technology Data Exchange (ETDEWEB)

    Cortes P, A.; Torre O, J. De la; Tejera R, A.; Becerril V, A.; Bribiesca S, L

    1990-04-15

    The Laboratory of Radioactive patterns account with a 4 {pi}{beta}-{gamma} coincidence system of recent acquisition with which absolute measures of radioactive activity with uncertainties of the order of 0.1% can be made. Since the coincidence method for the activity measure consists on detecting to the particle and the photon corresponding to oneself nuclear disintegration, it is necessary to elaborate special radioactive sources on thin supports, in order to allowing the maximum possible fluence of {beta} particles ({approx} 100%). This work a technique for the elaboration of these sources and for the measure of the thickness of the walls of the support is presented. (Author)

  14. Design and characteristics of beta-excited X-ray sources; Caracteristiques des sources de rayons X excitees par des particules beta; Konstruktsiya i kharakteristiki beta-vozbuzhdennykh istochnikov rentgenovskikh luchej; Diseno y caracteristicas de las fuentes de rayos X excitadas por particulas beta

    Energy Technology Data Exchange (ETDEWEB)

    Filosofo, I; Reiffel, L; Stone, C A; Voyvodic, L [Physics Division, Armour Research Foundation, Chicago, IL (United States)

    1962-01-15

    The paper reports on recent work on beta-excited X-ray sources. Results of detailed experimental investigation on the X-rays produced by the fission products Pm{sup 147}, Kr{sup 85} and Sr{sup 90} are described. X-ray yields and spectral distributions have been studied for target materials ranging from copper to uranium and in a variety of source-target geometries (transmission target, reflection target, sandwich target, intimate source-target mixtures). To interpret the experimental results, an analytical treatment of the processes involved in X-ray production by beta particles has been developed and is outlined. By taking into account bremsstrahlung, K-shell ionization, and fluorescent X-ray excitation, a convenient mathematical formulation may be derived for photon spectra and yields as functions of maximum {beta}-energy, target thickness and source configuration. The agreement between calculated and experimentally determined yields is excellent and confirms the merit of the analysis. It thus becomes possible to optimize the design of isotopic X-ray sources for specific applications. Kr{sup 85} and Pm{sup 147} prototype sources have been designed and 'their performance in thickness and composition-analysis measurements is discussed. A high level Pm{sup 147} source for industrial radiography has also been designed and its performance, along with the utility of image intensifiers to extend its applicability, is considered. Finally, a general review of potentialities, advantages and limitations of isotopic X-ray sources is given. (author) [French] Le memoire rend compte des recents travaux sur les sources de rayons X excitees par des particules beta. Il donne les resultats d'une etude experimentale detaillee sur les rayons X emis par les produits de fission {sup 147}Pm, {sup 85}Kr et {sup 90}Sr. Les auteurs ont etudie l'emission et la distribution spectrale des rayons X pour des cibles allant du cuivre a l'uranium, et ce dans plusieurs geometries source

  15. Response-surface models for deterministic effects of localized irradiation of the skin by discrete {beta}/{gamma} -emitting sources

    Energy Technology Data Exchange (ETDEWEB)

    Scott, B.R.

    1995-12-01

    Individuals who work at nuclear reactor facilities can be at risk for deterministic effects in the skin from exposure to discrete {Beta}- and {gamma}-emitting ({Beta}{gamma}E) sources (e.g., {Beta}{gamma}E hot particles) on the skin or clothing. Deterministic effects are non-cancer effects that have a threshold and increase in severity as dose increases (e.g., ulcer in skin). Hot {Beta}{gamma}E particles are {sup 60}Co- or nuclear fuel-derived particles with diameters > 10 {mu}m and < 3 mm and contain at least 3.7 kBq (0.1 {mu}Ci) of radioactivity. For such {Beta}{gamma}E sources on the skin, it is the beta component of the dose that is most important. To develop exposure limitation systems that adequately control exposure of workers to discrete {Beta}{gamma}E sources, models are needed for systems that adequately control exposure of workers to discrete {Beta}{gamma}E sources, models are needed for evaluating the risk of deterministic effects of localized {Beta} irradiation of the skin. The purpose of this study was to develop dose-rate and irradiated-area dependent, response-surface models for evaluating risks of significant deterministic effects of localized irradiation of the skin by discrete {Beta}{gamma}E sources and to use modeling results to recommend approaches to limiting occupational exposure to such sources. The significance of the research results as follows: (1) response-surface models are now available for evaluating the risk of specific deterministic effects of localized irradiation of the skin; (2) modeling results have been used to recommend approaches to limiting occupational exposure of workers to {Beta} radiation from {Beta}{gamma}E sources on the skin or on clothing; and (3) the generic irradiated-volume, weighting-factor approach to limiting exposure can be applied to other organs including the eye, the ear, and organs of the respiratory or gastrointestinal tract and can be used for both deterministic and stochastic effects.

  16. Factors affecting quality for beta dose rate measurements using ISO 6980 series I reference sources

    Energy Technology Data Exchange (ETDEWEB)

    Burns, R.E. Jr.; O`Brien, J.M. Jr. [Atlan-Tech, Rosewll, GA (United States)

    1993-12-31

    Atlan-Tech, Inc. has performed several calibrations of ISO 6980 Series 1 reference beta sources over the past two to three years. There were many problems encountered in attempting to compare the results of these calibrations with those from other laboratories, indicating the need for more standardization in the methodology employed for the measurement of the absorbed dose rate from ISO 6980 Series 1 reference beta sources. This document describes some of the problems encountered in attempting to intercompare results of beta dose-rate measurements. It proposes some solutions in an attempt to open a dialogue among facilities using reference beta standards for the purpose of promoting better measurement quality assurance through data intercomparison.

  17. Factors affecting quality for beta dose rate measurements using ISO 6980 series I reference sources

    International Nuclear Information System (INIS)

    Burns, R.E. Jr.; O'Brien, J.M. Jr.

    1993-01-01

    Atlan-Tech, Inc. has performed several calibrations of ISO 6980 Series 1 reference beta sources over the past two to three years. There were many problems encountered in attempting to compare the results of these calibrations with those from other laboratories, indicating the need for more standardization in the methodology employed for the measurement of the absorbed dose rate from ISO 6980 Series 1 reference beta sources. This document describes some of the problems encountered in attempting to intercompare results of beta dose-rate measurements. It proposes some solutions in an attempt to open a dialogue among facilities using reference beta standards for the purpose of promoting better measurement quality assurance through data intercomparison

  18. Procedure to carry out leakage test in beta radiation sealed sources emitters of 90Sr/90Y

    International Nuclear Information System (INIS)

    Alvarez R, J. T.

    2010-09-01

    In the alpha-beta room of the Secondary Laboratory of Dosimetric Calibration of the Metrology Department of Ionizing Radiations ophthalmic applicators are calibrated in absorbed dose terms in water D w ; these applicators, basically are emitter sealed sources of pure beta radiation of 90 Sr / 90 Y. Concretely, the laboratory quality system indicates to use the established procedure for the calibration of these sources, which establishes the requirement of to carry out a leakage test, before to calibrate the source. However, in the Laboratory leakage test certificates sent by specialized companies in radiological protection services have been received, in which are used gamma spectrometry equipment s for beta radiation leakage tests, since it is not reliable to detect pure beta radiation with a scintillating detector with NaI crystal, (because it could detect the braking radiation produced in the detector). Therefore the Laboratory has had to verify the results of the tests with a correct technique, with the purpose of determining the presence of sources with their altered integrity and radioactive material leakage. The objective of this work is to describe a technique for beta activity measurement - of the standard ISO 7503, part 1 (1988) - and its application with a detector Gm plane (type pankage) in the realization of leakage tests in emitter sources of pure beta radiation, inside the mark of quality assurance indicated by the report ICRU 76. (Author)

  19. Standardization method for alpha and beta surface sources

    Energy Technology Data Exchange (ETDEWEB)

    Sahagia, M; Grigorescu, E L; Razdolescu, A C; Ivan, C [Institute of Physics and Nuclear Engineering, Institute of Atomic Physics, PO Box MG-6, R-76900 Bucharest, (Romania)

    1994-01-01

    The installation and method of standardization of large surface alpha and beta sources are presented. A multiwire, flow-type proportional counter and the associated electronics is used. The counter is placed in a lead-shield. The response of the system in (s[sup -1]/Bq) or (s[sup -1]/(particle x s[sup -1])) was determined for [sup 241] Am, [sup 239] Pu, [sup 147] Pm, [sup 204] Tl, [sup 90](Sr+Y) and [sup 137] Cs using standard sources with different dimensions, from some mm[sup 2] to 180 x 220 mm[sup 2]. The system was legally attested for expanded uncertainties of +7%. (Author).

  20. Calibrated radioactive sources - absolute measurements using a 4{pi} {beta}-{gamma} apparatus; Sources etalons de radioactivite - mesures absolues au moyen d'un ensemble 4{pi} {beta}-{gamma}

    Energy Technology Data Exchange (ETDEWEB)

    Benoit, P; Philis, C [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1965-07-01

    In this paper, the principle of the standardization of the radioisotopes by the 4{pi} {beta} - {gamma} coincidence method is reminded. Some theoretical examples are given emphasizing on instrumental coincidences and their corrections. The experimental apparatus is described: one discusses the choice of the experimental conditions for the many isotopes measured. Results are given and discussed. In appendix we describe the preparation of the sources. (authors) [French] Dans ce rapport, nous rappelons d'abord le principe de la methode d'etalonnage 4{pi} {beta} - {gamma} en donnant quelques exemples theoriques et en insistant sur la correction des erreurs instrumentales. Une description critique de l'appareillage utilise est donnee. On discute le choix des conditions experimentales pour divers isotopes mesures et les resultats obtenus. En annexe, nous decrivons la fabrication des sources que nous mesurons.

  1. A simple method for determining the activity of large-area beta sources constructed from anodized aluminum foils

    International Nuclear Information System (INIS)

    Stanga, D.

    2014-01-01

    A simple method has been developed for determining the activity of large-area beta reference sources in anodized aluminum foils. It is based on the modeling of the transmission of beta rays through thin foils in planar geometry using Monte Carlo simulation. The method was checked experimentally and measurement results show that the activity of large-area beta reference sources in anodized aluminum foils can be measured with standard uncertainties smaller than the limit of 10% required by ISO 8769. - Highlights: • A method for determining the activity of large-area beta sources is presented. • The method is based on a model of electron transport in planar geometry. • The method makes use of linear programming for determining the activity. • The uncertainty of the method is smaller than 10%

  2. Endovascular Irradiations with beta sources

    Energy Technology Data Exchange (ETDEWEB)

    Scmidt, W F.O.; Hawliczek, R [Inst of Radiooncology IRO, Donauspital, Vienna (Austria); Mueck, K [Austrian Research Centre, Siebersdorf ARCS (Austria); Lehmann, D [Inst of Radiotherapy, Univ. Dresden (Germany); Pichler, L [Ludwig Boltzmann Institute for Endovascular Radiotherapy, Donauspital, Vienna (Austria)

    1999-12-31

    For treatment of restenoses tubes (inner/outer diameter 1 and 2 mm; length 3 or 5 mm) with Y-90 foils, shielded by Ti-layers on all sides have been developed (activity 0.5 - 2 GBq). Quality checks with plastic scintillators have been developed and are correlated to absolute dose measurements performed with TLDs (1x1 mm2; 40 mg/cm2). TLD-handling and calibration for beta-dosimetry are described. Additional measurements for depth-dose and dose distribution around the tubes were done with GAFCHROMIC- films and compared to Monte-Carlo calculations with the MCNP4-code, yielding a half-value depth of 0.8 mm from the tube-surface. Manufacturing and delivery of the sources including leakage tests has been standardized, treatments (irradiation times <5min; irradiation length <30mm) are planned to start in spring `98. (authors) 1 refs., 5 figs.

  3. A new treatment planning formalism for catheter-based beta sources used in intravascular brachytherapy.

    Science.gov (United States)

    Patel, N S; Chiu-Tsao, S T; Tsao, H S; Harrison, L B

    2001-01-01

    Intravascular brachytherapy (IVBT) is an emerging modality for the treatment of atherosclerotic lesions in the artery. As part of the refinement in this rapidly evolving modality of treatment, the current simplistic dosimetry approach based on a fixed-point prescription must be challenged by future rigorous dosimetry method employing image-based three-dimensional (3D) treatment planning. The goals of 3D IVBT treatment planning calculations include (1) achieving high accuracy in a slim cylindrical region of interest, (2) accounting for the edge effect around the source ends, and (3) supporting multiple dwell positions. The formalism recommended by Task Group 60 (TG-60) of the American Association of Physicists in Medicine (AAPM) is applicable for gamma sources, as well as short beta sources with lengths less than twice the beta particle range. However, for the elongated beta sources and/or seed trains with lengths greater than twice the beta range, a new formalism is required to handle their distinctly different dose characteristics. Specifically, these characteristics consist of (a) flat isodose curves in the central region, (b) steep dose gradient at the source ends, and (c) exponential dose fall-off in the radial direction. In this paper, we present a novel formalism that evolved from TG-60 in maintaining the dose rate as a product of four key quantities. We propose to employ cylindrical coordinates (R, Z, phi), which are more natural and suitable to the slim cylindrical shape of the volume of interest, as opposed to the spherical coordinate system (r, theta, phi) used in the TG-60 formalism. The four quantities used in this formalism include (1) the distribution factor, H(R, Z), (2) the modulation function, M(R, Z), (3) the transverse dose function, h(R), and (4) the reference dose rate at 2 mm along the perpendicular bisector, D(R0=2 mm, Z0=0). The first three are counterparts of the geometry factor, the anisotropy function and the radial dose function in the

  4. [Dietary sources of vitamin A, C, E and beta-carotene in a adult Mediterranean population].

    Science.gov (United States)

    Gascón-Vila, P; Ribas, L; García-Closas, R; Farrán Codina, A; Serra-Majem, L

    1999-01-01

    Estimation of vitamin A, C, E and beta-carotene food sources, as well as its nutritional intake and density in adult Catalonian population. A cross-sectional study was conducted over 2,346 individuals obtained from the sample of Catalonian Survey of Nutritional Status aged 18 to 75 years old to estimate usual dietary intake of vitamins A, C, E and beta-carotene using two 24 hour dietary recalls administered in two periods (june-july and november-december of 1992). Replicated 24 hour Recalls allowed for estimation of usual intake. Calculation of food sources for vitamins encompassed three phases: foods transformation into nutrients, aggregation of foods in categories and sum of nutrients by food categories. Intake of vitamin A (equivalents of retinol of provitamin A and vitamin A), E, C were closely near or higher than RDA. Nutritional density of vitamin C, E and beta-carotene were higher in female group. Nutritional density was positively associated to age for vitamins C, E and beta-carotene. Addition fat was the first source of vitamin E and it reached 33.8% of total vitamin E intake. Vegetables contributed in 17.3 % to the total vitamin C, whereas fruits accounted for 57.9%. Fruits recached 40.6% of the total beta-carotene intake, whereas vegetables accounted for 34.8%. The major contributors of vitamin A were milk and dairy products. Nutritional intake of vitamin A, C and E are over the RDA parameters suggesting an healthy nutritional status that must be confirmed and ratify by biochemical assessment. Nutritional densities were higher in female gender than in males in vitamins C, E, and beta-carotene possibly due to a higher intake of total lipids in male gender than in females. Nutritional density was positively associated to age in the same group of vitamins, suggesting a higher intake of empty calories in younger group. Fruits and Vegetables accounted for more than 70% of vitamin C and beta-carotene and major contributors were citrics, carrots, tomatoes

  5. Preliminary design of experiment ALVAND 1 and low beta plasma source

    International Nuclear Information System (INIS)

    Anvari, A.; Azodi, H.; Naraghi, M.; Taherzadeh, M.; Torabi-Fard, A.

    1975-12-01

    The ultimate goal of a two years program, namely ''ALVAND PROJECT'' and problems concerned with the achievement of controlled thermonuclear reactions in Iran is covered. The report consists of six sections. The introduction deals with the advantages of a linear theta pinch and its comparison with toroidal and mirror devices. Attention has been paid to two important properties of the ALVAND 1 device, namely, its property of carrying out important missions in support of high beta controlled thermonuclear research and also its acting as a source for developing different diagnostic apparatus and excercising different measurement techniques. Expected plasma parameters for ALVAND 1 are given in the third section. In the fourth section the low beta plasma source and the important diagnostic techniques that may be developed are discussed. References are given in the fifth section. The calculation of the minimum required radius of a toroidal theta pinch reactor has been given in an appendix, which covers at the same time 2 schematic figures. Finally a program schedule is presented in section six

  6. Absorbed dose from a beta source as shown by thermoluminescence dosimetry

    International Nuclear Information System (INIS)

    Wintle, A.G.; Aitken, M.J.

    1977-01-01

    The depth-dose curve was obtained for a 90 Sr- 90 Y beta source using a fine grain TL phosphor to measure the observed dose, aluminium absorbers being interposed between the source and the detector; the curve went through a maximum at an absorber thickness of about 40 mg cm -2 . This curve was then used to predict the average dose rate to various thicknesses of calcium fluoride which has a similar absorption characteristic to aluminium; these values were compared with experimentally determined dose rates. This work was done in connection with thermoluminescence dating of flint and calcite in archaeology and geology. (author)

  7. Response of a multi-element dosimeter to calibrated beta sources with E/sub max/ from 0.23 to 3.5 MeV

    International Nuclear Information System (INIS)

    Endres, G.W.R.; Scherpelz, R.I.; Roberson, P.L.

    1982-06-01

    The responses of several different dosimeter absorber systems were studied to determine their usefulness in beta radiation fields. Exposures to several different beta emitters were conducted at the PNL Calibrations Laboratory. The sources used are: 147 Pm, 85 Kr, U(nat), 90 Sr- 90 Y, and 106 Ru- 106 Rh. The maximum energy of these beta emitters varies from 0.23 to 3.5 MeV. The beta sources are calibrated for absorbed dose to tissue at a depth of 0.007 cm. Measurements of response for 4, 5, and 7 element versions of the dosimeter were made. All data reported were obtained from sets of three TLDs exposed under each absorber and for each of the radiation sources

  8. Reference sources for the calibration of surface contamination monitors - Beta-emitters (maximum beta energy greater than MeV) and alpha-emitters (International Standard Publication ISO 8769:1988)

    International Nuclear Information System (INIS)

    Stefanik, J.

    2001-01-01

    This International Standard specifies the characteristics of reference sources of radioactive surface contamination, traceable to national measurement standards, for the calibration of surface contamination monitors. This International Standard relates to alpha-emitters and to beta-emitters of maximum beta energy greater than 0,15 MeV. It does not describe the procedures involved in the use of these reference sources for the calibration of surface contamination monitors. Such procedures are specified in IEC Publication 325 and other documents. This International Standard specifies reference radiations for the calibration of surface contamination monitors which take the form of adequately characterized large area sources specified, without exception, in terms of activity and surface emission rate, the evaluation of these quantities being traceable to national standards

  9. Microglia and macrophages are major sources of locally produced transforming growth factor-beta1 after transient middle cerebral artery occlusion in rats

    DEFF Research Database (Denmark)

    Lehrmann, E; Kiefer, R; Christensen, Thomas

    1998-01-01

    The potentially neurotrophic cytokine transforming growth factor-beta1 (TGF-beta1) is locally expressed following human stroke and experimental ischemic lesions, but the cellular source(s) and profile of induction have so far not been established in experimental focal cerebral ischemia. This stud...

  10. Radioactivity determination of sealed pure beta-sources by surface dose measurements and Monte Carlo simulations

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Chang Heon [Interdisciplinary Program in Radiation Applied Life Science, Seoul National University College of Medicine, Seoul (Korea, Republic of); Jung, Seongmoon [Program in Biomedical Radiation Sciences, Department of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University, Seoul (Korea, Republic of); Choi, Kanghyuk; Son, Kwang-Jae; Lee, Jun Sig [Hanaro Applications Research, Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Ye, Sung-Joon, E-mail: sye@snu.ac.kr [Interdisciplinary Program in Radiation Applied Life Science, Seoul National University College of Medicine, Seoul (Korea, Republic of); Program in Biomedical Radiation Sciences, Department of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University, Seoul (Korea, Republic of); Center for Convergence Research on Robotics, Advance Institutes of Convergence Technology, Seoul National University, Suwon (Korea, Republic of)

    2016-04-21

    This study aims to determine the activity of a sealed pure beta-source by measuring the surface dose rate using an extrapolation chamber. A conversion factor (cGy s{sup −1} Bq{sup −1}), which was defined as the ratio of surface dose rate to activity, can be calculated by Monte Carlo simulations of the extrapolation chamber measurement. To validate this hypothesis the certified activities of two standard pure beta-sources of Sr/Y-90 and Si/P-32 were compared with those determined by this method. In addition, a sealed test source of Sr/Y-90 was manufactured by the HANARO reactor group of KAERI (Korea Atomic Energy Research Institute) and used to further validate this method. The measured surface dose rates of the Sr/Y-90 and Si/P-32 standard sources were 4.615×10{sup −5} cGy s{sup −1} and 2.259×10{sup −5} cGy s{sup −1}, respectively. The calculated conversion factors of the two sources were 1.213×10{sup −8} cGy s{sup −1} Bq{sup −1} and 1.071×10{sup −8} cGy s{sup −1} Bq{sup −1}, respectively. Therefore, the activity of the standard Sr/Y-90 source was determined to be 3.995 kBq, which was 2.0% less than the certified value (4.077 kBq). For Si/P-32 the determined activity was 2.102 kBq, which was 6.6% larger than the certified activity (1.971 kBq). The activity of the Sr/Y-90 test source was determined to be 4.166 kBq, while the apparent activity reported by KAERI was 5.803 kBq. This large difference might be due to evaporation and diffusion of the source liquid during preparation and uncertainty in the amount of weighed aliquot of source liquid. The overall uncertainty involved in this method was determined to be 7.3%. We demonstrated that the activity of a sealed pure beta-source could be conveniently determined by complementary combination of measuring the surface dose rate and Monte Carlo simulations.

  11. Monte Carlo Simulations Validation Study: Vascular Brachytherapy Beta Sources

    International Nuclear Information System (INIS)

    Orion, I.; Koren, K.

    2004-01-01

    During the last decade many versions of angioplasty irradiation treatments have been proposed. The purpose of this unique brachytherapy is to administer a sufficient radiation dose into the vein walls in order to prevent restonosis, a clinical sequel to balloon angioplasty. The most suitable sources for this vascular brachytherapy are the β - emitters such as Re-188, P-32, and Sr-90/Y-90, with a maximum energy range of up to 2.1 MeV [1,2,3]. The radioactive catheters configurations offered for these treatments can be a simple wire [4], a fluid filled balloon or a coated stent. Each source is differently positioned inside the blood vessel, and the emitted electrons ranges therefore vary. Many types of sources and configurations were studied either experimentally or with the use of the Monte Carlo calculation technique, while most of the Monte Carlo simulations were carried out using EGS4 [5] or MCNP [6]. In this study we compared the beta-source absorbed-dose versus radial-distance of two treatment configurations using MCNP and EGS4 simulations. This comparison was aimed to discover the differences between the MCNP and the EGS4 simulation code systems in intermediate energies electron transport

  12. Preliminary Results of Nuclear Fluorescence Imaging of Alpha and Beta Emitting Sources

    International Nuclear Information System (INIS)

    Feener, Jessica S.; Charlton, William S.

    2013-06-01

    The preliminary results from a series of nuclear fluorescence imaging experiments using a variety of radioactive sources and shielding are given. These experiments were done as part of a proof of concept to determine if nuclear fluorescence imaging could be used as a safeguards measurements tool or for nuclear warhead verification for nuclear arms control treaties such as the New Strategic Arms Reduction Treaty and the Fissile Material Cut-Off Treaty. An off-the-shelf Princeton Instruments charged coupled device camera system was used to image the emission of fluorescence photons from the de-excitation of nitrogen molecules in air that have been excited by ionizing radiation. The fluorescence emissions are primarily in the near ultraviolet range; between the wavelengths of 300 and 400 nm. Fluorescent imaging techniques are currently being investigated in a number of applications. A French research team has successfully demonstrated this concept for remote imaging of alpha contamination. It has also been shown that the phenomenon can be seen through translucent materials and that alpha radiation can be seen in the presence of large gamma backgrounds. Additionally, fluorescence telescopes and satellites utilize the de-excitation of nitrogen molecules to observe cosmic ray showers in the atmosphere. In cosmic ray shower detection, electrons are the main contributor to the excitation of the of nitrogen molecules in air. The experiments presented in this paper were designed to determine if the imaging system could observe beta emitting sources, differentiate between beta emitters and alpha emitting materials such as uranium oxide and uranium metal, and to further investigate the phenomenon through translucent and non-translucent materials. The initial results show that differentiation can be made between beta and alpha emitting sources and that the device can observe the phenomenon through very thin non-transparent material. Additionally, information is given on the

  13. Development of beta reference radiations

    International Nuclear Information System (INIS)

    Wan Zhaoyong; Cai Shanyu; Li Yanbo; Yin Wei; Feng Jiamin; Sun Yuhua; Li Yongqiang

    1997-09-01

    A system of beta reference radiation has been developed, that is composed of 740 MBq 147 Pm beta source, 74 MBq and 740 MBq 90 Sr + 90 Y β sources, compensation filters, a source handling tool, a source jig, spacing bars, a shutter, a control unit and a beta dose meter calibration stand. For 740 MBq 147 Pm and 74 MBq 90 Sr + 90 Y beta reference radiations with compensation filters and 740 MBq 90 Sr + 90 Y beta reference radiation without compensation filter, at 20 cm, 30 cm and 30 cm distance separately; the residual energy of maximum is 0.14 MeV, 1.98 MeV and 2.18 MeV separately; the absorbed dose to tissue D (0.07) is 1.547 mGy/h (1996-05-20), 5.037 mGy/h (1996-05-10) and 93.57 mGy/h (1996-05-15) separately; the total uncertainty is 3.0%, 1.7% and 1.7% separately. For the first and the second beta reference radiation, the dose rate variability in the area of 18 cm diameter in the plane perpendicular to the beta-ray beam axis is within +-6% and +-3% separately. (3 refs., 2 tabs., 8 figs.)

  14. Use of gaseous tritium light sources (Beta lights) with respect to nocturnal illumination

    International Nuclear Information System (INIS)

    Solomon, D.E.

    1988-01-01

    A number/letter plate for use in, for example darkened buildings has spaced apart gaseous tritium light sources (beta lights) arranged centrally along the indicia on a reflective background sealed in clear translucent plastics. Uses include house numbers, name plates, telephone numbers, notices, product advertisements, vehicle registration plates and names or trade marks on products. (author)

  15. Radiation protection during brachytherapy, radiosynoviorthesis or radioimmunotherapy using liquid beta sources. Statement of the SSK; Strahlenschutz bei der Therapie mit Beta-Strahlern in fluessiger Form im Rahmen einer Brachytherapie, Radiosynoviorthese und einer Radioimmuntherapie. Empfehlung der Strahlenschutzkommission

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2005-07-01

    Unsealed liquid beta sources (Sr-89, Y-90, I-131, Er-169, Re-186, Re-188) are used increasingly in nuclear medicine for therapeutic purposes. In contrast to radioiodine therapy of thyroid diseases, interdisciplinary cooperation may be necessary (cardiology, orthopedic, rheumatology, oncology etc.), e.g. during applicaiton outside nuclear medicine or in case of non-nuclear invasive application methods. During preparation and application of beta sources, enhanced radiation exposure of the medical staff, especially doctors, is possible both in consequence of external exposure and in case of contaminations. Routine applications of unsealed liquid beta sources therefore necessitate specified radiation protection measures as specified in the guideline ''Strahlenschutz in der Medizin''. (orig.)

  16. Development of a gas-ionization {beta}-spectrometer; Etude et realisation d'un spectrometre {beta} a ionisation gazeuse

    Energy Technology Data Exchange (ETDEWEB)

    Le Du, R [Commissariat a l' Energie Atomique, Bruyeres-le-Chatel (France). Centre d' Etudes

    1968-05-15

    We intend to develop in our laboratory a {beta}-spectrometer. This apparatus will have two main objectives: 1 - the determination of the nature and the degree of purity of certain {beta}-emitting radioactive substances; 2 - the study of an activity calibration process for {beta}-emitting radioactive sources. (author) [French] Nous nous proposons d'etudier et de realiser dans notre laboratoire un spectrometre {beta}. Cet appareil aura deux buts principaux: 1 - determiner la nature et le degre de purete de certains corps radioactifs emetteurs {beta}; 2 - permettre l'etude d'un procede d'etalonnage en activite de sources radioactives emetteurs {beta}. (auteur)

  17. Procedure to carry out leakage test in beta radiation sealed sources emitters of {sup 90}Sr/{sup 90}Y; Procedimiento para realizar prueba de fuga en fuentes selladas de radiacion beta emisoras de {sup 90}Sr/{sup 90}Y

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez R, J. T., E-mail: trinidad.alvarez@inin.gob.m [ININ, Departamento de Metrologia de Radiaciones Ionizantes, Laboratorio Secundario de Calibracion Dosimetrica, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2010-09-15

    In the alpha-beta room of the Secondary Laboratory of Dosimetric Calibration of the Metrology Department of Ionizing Radiations ophthalmic applicators are calibrated in absorbed dose terms in water D{sub w}; these applicators, basically are emitter sealed sources of pure beta radiation of {sup 90}Sr / {sup 90}Y. Concretely, the laboratory quality system indicates to use the established procedure for the calibration of these sources, which establishes the requirement of to carry out a leakage test, before to calibrate the source. However, in the Laboratory leakage test certificates sent by specialized companies in radiological protection services have been received, in which are used gamma spectrometry equipment s for beta radiation leakage tests, since it is not reliable to detect pure beta radiation with a scintillating detector with NaI crystal, (because it could detect the braking radiation produced in the detector). Therefore the Laboratory has had to verify the results of the tests with a correct technique, with the purpose of determining the presence of sources with their altered integrity and radioactive material leakage. The objective of this work is to describe a technique for beta activity measurement - of the standard ISO 7503, part 1 (1988) - and its application with a detector Gm plane (type pankage) in the realization of leakage tests in emitter sources of pure beta radiation, inside the mark of quality assurance indicated by the report ICRU 76. (Author)

  18. Design of a neutrino source based on beta beams

    Directory of Open Access Journals (Sweden)

    E. Wildner

    2014-07-01

    Full Text Available “Beta beams” produce collimated pure electron (antineutrino beams by accelerating beta active ions to high energies and having them decay in a racetrack shaped storage ring of 7 km circumference, the decay ring. EUROnu beta beams are based on CERN infrastructures and existing machines. Using existing machines may be an advantage for the cost evaluation, but will also constrain the physics performance. The isotope pair of choice for the beta beam is ^{6}He and ^{18}Ne. However, before the EUROnu studies one of the required isotopes, ^{18}Ne, could not be produced in rates that satisfy the needs for physics of the beta beam. Therefore, studies of alternative beta emitters, ^{8}Li and ^{8}B, with properties interesting for a beta beam have been proposed and have been studied within EUROnu. These alternative isotopes could be produced by using a small storage ring, in which the beam traverses a target, creating the ^{8}Li and ^{8}B isotopes. This production ring, the injection linac and the target system have been evaluated. Measurements of the cross section of the reactions to produce the beta beam isotopes show interesting results. A device to collect the produced isotopes from the target has been developed and tested. However, the yields of ^{8}Li and ^{8}B, using the production ring for production of ^{8}Li and ^{8}B, is not yet, according to simulations, giving the rates of isotopes that would be needed. Therefore, a new method of producing the ^{18}Ne isotope has been developed and tested giving good production rates. A 60 GHz ECRIS prototype, the first in the world, was developed and tested for ion production with contributions from EUROnu. The decay ring lattices for the ^{8}Li and ^{8}B have been developed and the lattice for ^{6}He and ^{18}Ne has been optimized to ensure the high intensity ion beam stability.

  19. Source analysis of beta-synchronisation and cortico-muscular coherence after movement termination based on high resolution electroencephalography.

    Directory of Open Access Journals (Sweden)

    Muthuraman Muthuraman

    Full Text Available We hypothesized that post-movement beta synchronization (PMBS and cortico-muscular coherence (CMC during movement termination relate to each other and have similar role in sensorimotor integration. We calculated the parameters and estimated the sources of these phenomena.We measured 64-channel EEG simultaneously with surface EMG of the right first dorsal interosseus muscle in 11 healthy volunteers. In Task1, subjects kept a medium-strength contraction continuously; in Task2, superimposed on this movement, they performed repetitive self-paced short contractions. In Task3 short contractions were executed alone. Time-frequency analysis of the EEG and CMC was performed with respect to the offset of brisk movements and averaged in each subject. Sources of PMBS and CMC were also calculated.High beta power in Task1, PMBS in Task2-3, and CMC in Task1-2 could be observed in the same individual frequency bands. While beta synchronization in Task1 and PMBS in Task2-3 appeared bilateral with contralateral predominance, CMC in Task1-2 was strictly a unilateral phenomenon; their main sources did not differ contralateral to the movement in the primary sensorimotor cortex in 7 of 11 subjects in Task1, and in 6 of 9 subjects in Task2. In Task2, CMC and PMBS had the same latency but their amplitudes did not correlate with each other. In Task2, weaker PMBS source was found bilaterally within the secondary sensory cortex, while the second source of CMC was detected in the premotor cortex, contralateral to the movement. In Task3, weaker sources of PMBS could be estimated in bilateral supplementary motor cortex and in the thalamus. PMBS and CMC appear simultaneously at the end of a phasic movement possibly suggesting similar antikinetic effects, but they may be separate processes with different active functions. Whereas PMBS seems to reset the supraspinal sensorimotor network, cortico-muscular coherence may represent the recalibration of cortico-motoneuronal and

  20. Source analysis of beta-synchronisation and cortico-muscular coherence after movement termination based on high resolution electroencephalography.

    Science.gov (United States)

    Muthuraman, Muthuraman; Tamás, Gertrúd; Hellriegel, Helge; Deuschl, Günther; Raethjen, Jan

    2012-01-01

    We hypothesized that post-movement beta synchronization (PMBS) and cortico-muscular coherence (CMC) during movement termination relate to each other and have similar role in sensorimotor integration. We calculated the parameters and estimated the sources of these phenomena.We measured 64-channel EEG simultaneously with surface EMG of the right first dorsal interosseus muscle in 11 healthy volunteers. In Task1, subjects kept a medium-strength contraction continuously; in Task2, superimposed on this movement, they performed repetitive self-paced short contractions. In Task3 short contractions were executed alone. Time-frequency analysis of the EEG and CMC was performed with respect to the offset of brisk movements and averaged in each subject. Sources of PMBS and CMC were also calculated.High beta power in Task1, PMBS in Task2-3, and CMC in Task1-2 could be observed in the same individual frequency bands. While beta synchronization in Task1 and PMBS in Task2-3 appeared bilateral with contralateral predominance, CMC in Task1-2 was strictly a unilateral phenomenon; their main sources did not differ contralateral to the movement in the primary sensorimotor cortex in 7 of 11 subjects in Task1, and in 6 of 9 subjects in Task2. In Task2, CMC and PMBS had the same latency but their amplitudes did not correlate with each other. In Task2, weaker PMBS source was found bilaterally within the secondary sensory cortex, while the second source of CMC was detected in the premotor cortex, contralateral to the movement. In Task3, weaker sources of PMBS could be estimated in bilateral supplementary motor cortex and in the thalamus. PMBS and CMC appear simultaneously at the end of a phasic movement possibly suggesting similar antikinetic effects, but they may be separate processes with different active functions. Whereas PMBS seems to reset the supraspinal sensorimotor network, cortico-muscular coherence may represent the recalibration of cortico-motoneuronal and spinal systems.

  1. A new mini-extrapolation chamber for beta source uniformity measurements

    International Nuclear Information System (INIS)

    Oliveira, M.L.; Caldas, L.V.E.

    2006-01-01

    According to recent international recommendations, beta particle sources should be specified in terms of absorbed dose rates to water at the reference point. However, because of the clinical use of these sources, additional information should be supplied in the calibration reports. This additional information include the source uniformity. A new small volume extrapolation chamber was designed and constructed at the Calibration Laboratory at Instituto de Pesquisas Energeticas e Nucleares, IPEN, Brazil, for the calibration of 90 Sr+ 90 Y ophthalmic plaques. This chamber can be used as a primary standard for the calibration of this type of source. Recent additional studies showed the feasibility of the utilization of this chamber to perform source uniformity measurements. Because of the small effective electrode area, it is possible to perform independent measurements by varying the chamber position by small steps. The aim of the present work was to study the uniformity of a 90 Sr+ 90 Y plane ophthalmic plaque utilizing the mini extrapolation chamber developed at IPEN. The uniformity measurements were performed by varying the chamber position by steps of 2 mm in the source central axis (x-and y-directions) and by varying the chamber position off-axis by 3 mm steps. The results obtained showed that this small volume chamber can be used for this purpose with a great advantage: it is a direct method, being unnecessary a previously calibration of the measurement device in relation to a reference instrument, and it provides real -time results, reducing the time necessary for the study and the determination of the uncertainties related to the measurements. (authors)

  2. Sources of beta diversity in estuarine benthic macro-invertebrate communities in the Baltic Sea - North Sea transition

    DEFF Research Database (Denmark)

    Josefson, Alf B.; Göke, Cordula

    Identification of sources of beta diversity, the change of diversity, is important to understand regulation of overall diversity. Additive partitioning of diversity (species richness and expH) compared to random, was performed on a quantitative benthic macro-invertebrate collection of > 400 speci...

  3. Calibrating instrument of plane sources of alpha and beta

    International Nuclear Information System (INIS)

    Liu Hongquan

    1988-12-01

    The instrument is standard instrument for measuring emissivity of plane sources of alpha and beta under 2π geometry in radionuclide metrologic technique. It is composed of box-type detector and truck-type NIM (made in China) to make up integral equipment. Its detector is composed of multivire proportion counter with electrostatic screen of zero potential and unique anticoincidence multiwire proportion counter in lead chamber. The characteristics of the instrument are as follows: Low background (α≤ 0.006 C · P · M/cm 2 , β≤ 0.03 C · P · M/cm 2 ), low work voltage, low noise, high detective efficiency (>99%), large sensitive area (150 x 100 mm), less dead time, possessing micro accidental anticoincidences, better property of high voltage plateau and discriminating. It has fulfiled the requirements of standard which possesses wide rang (50 C · M · M ∼ 10 6 C · P · M), high precision (± 5 ∼ 6% for 50 C · P · M ∼ 220 C · P · M, ≤ ± 0.6% for 200 C · P · M ∼ 10 6 C · P · M); besides, have solved the problem of instability which usualy occurs in same kind of equipments for measuring a sources with less face conductivity

  4. Monte Carlo dosimetry of a tandem positioned beta-emitting intravascular brachytherapy source train

    International Nuclear Information System (INIS)

    Wallace, Steven A.; Schumer, Wendy; Horrigan, Mark

    2002-01-01

    Prevention of restenosis following interventional coronary procedures with catheter based beta-emitting sources is currently under clinical trial investigations. Systems utilizing fixed length source trains limit the clinician's ability to increase the radiation source length as required. A technique known as 'pull back' is used when the segment of artery requiring radiation is longer than the available fixed length source train. In this instance, tandem positioning of the fixed length source is used to treat the longer length of artery. The aim of this study was to examine the dosimetry of the junction region associated with pull back treatments using a commercially available 90 Sr/Y catheter based intravascular brachytherapy source train. Dose profiles were calculated, using the Monte Carlo code MCNP4B, at radial distances of 1.5, 2.0, and 2.5 mm for pull back techniques using 2.5 mm overlapping, abutting, and 2.5 mm spaced source trains. Results at the protocol prescription radius of 2 mm showed a junction dose elevated 61% above prescription for 2.5 mm overlapping source trains. For 2.5 mm spaced trains, this figure falls to 64% below prescription dose. In contrast, abutted source trains exhibited only a 1% depression below prescription dose in the junction region. The reference point dose rate per unit activity of this source was found to be consistent with previous studies

  5. Determination of the dose rapidity of a 90 Sr beta radiation source using thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Gonzalez M, P.R.; Azorin N, J.; Rivera M, T.

    2000-01-01

    The thermoluminescent dosemeters developed in Mexico, have been used efficiently in environmental and personal dosimetry. When the dose rate of some source is not known can be estimated with the use of thermoluminescent dosemeters taking in account the geometrical array used in the irradiations for reproducibility of the results in posterior irradiations. In this work it was estimated the dose rate of a 90 Sr- 90 Y beta radiation source which is property of the Nuclear Sciences Institute, UNAM, therefore it was l ended to the Metropolitan Autonomous University- Iztapalapa Unit for the characterization of new Tl materials, taking account of the institutional collaboration agreements. (Author)

  6. Determination of the direction to a source of antineutrinos via inverse beta decay in Double Chooz

    Science.gov (United States)

    Nikitenko, Ya.

    2016-11-01

    To determine the direction to a source of neutrinos (and antineutrinos) is an important problem for the physics of supernovae and of the Earth. The direction to a source of antineutrinos can be estimated through the reaction of inverse beta decay. We show that the reactor neutrino experiment Double Chooz has unique capabilities to study antineutrino signal from point-like sources. Contemporary experimental data on antineutrino directionality is given. A rigorous mathematical approach for neutrino direction studies has been developed. Exact expressions for the precision of the simple mean estimator of neutrinos' direction for normal and exponential distributions for a finite sample and for the limiting case of many events have been obtained.

  7. SOURCE 1ST 2.0: development and beta testing

    International Nuclear Information System (INIS)

    Barber, D.H.; Iglesias, F.C.; Hoang, Y.; Dickson, L.W.; Dickson, R.S.; Richards, M.J.; Gibb, R.A.

    1999-01-01

    SOURCE 1ST 2.0 is the Industry Standard fission product release code that is being developed by Ontario Power Generation, New Brunswick Power, Hydro-Quebec, and Atomic Energy of Canada Ltd. This paper is a report on recent progress on requirement specification, code development, and module verification and validation activities. The theoretical basis for each model in the code is described in a module Software Theory Manual. The development of SOURCE IST 2.0 has required code design decisions about how to implement the software requirements. Development and module testing of the β1 release of SOURCE IST 2.0 (released in July 1999) have led to some interesting insights into fission product release modelling. The beta testing process has allowed code developers and analysts to refine the software requirements for the code. The need to verify physical reference data has guided some decisions on the code and data structure design. Examples of these design decisions are provided. Module testing, and verification and validation activities are discussed. These activities include code-targeted testing, stress testing, code inspection, comparison of code with requirements, and comparison of code results with independent algebraic, numerical, or semi-algebraic calculations. The list of isotopes to be modelled by SOURCE IST 2.0 provides an example of a subset of a reference data set. Isotopes are present on the list for a variety of reasons: personnel or public dose, equipment dose (for environmental qualification), fission rate and actinide modelling, or stable (or long-lived) targets for activation processes. To accommodate controlled changes to the isotope list, the isotope list and associated nuclear data are contained in a reference data file. The questions of multiple computing platforms, and of Year 2000 compliance have been addressed by programming rules for the code. By developing and testing modules on most of the different platforms on which the code is intended

  8. The Beta Israel: Return to the source? | Zegeye | Africa Insight

    African Journals Online (AJOL)

    Even after more than two decades, over 70 000 Ethiopian Jews - the Beta Israel - have still not been fully accepted in Israel, in danger of becoming an ethnically defined 'under-class'. The potential of Beta Israel contributions to both Israeli and Ethiopian society should be recognised. Africa Insight Vol.34(1) 2004: 69-75 ...

  9. Peculiarities of the clinical course of radiation sickness and organizational decisions for radiation accidents with beta-gamma sources

    International Nuclear Information System (INIS)

    Guskova, A.K.; Gusev, I.A.

    1998-01-01

    The analysis of a number of recent large scale accidents involving beta-gamma sources in the last 40 years, such as those of the Marshall Islands (1954); Windscale, UK (1957); Chernobyl, USSR (1986) and Goiania, Brazil (1987) demonstrates the predominance and importance of health and social impacts. (author)

  10. A new method for characterizing beta-ray ophthalmic applicator sources

    International Nuclear Information System (INIS)

    Sayeg, J.A.; Gregory, R.C.

    1991-01-01

    A technique is described which enables one to obtain detailed dose characteristics of 90Sr beta-ray ophthalmic applicators. A radiochromic radiation detector which is a solid-state solution of hexahydroxyethyl pararosaniline cyanide in a nylon polymer (i.e., thin foil), has been used to determine the surface dose rate and dose distribution of these sources. The detectors are rugged, easily handled, have an equivalent response (optical density per unit absorbed dose) to photons and electrons, and produce high-resolution images. They have been found useful for this application due to the high surface dose rates [0.10-1.0 Gy (H2O)/s] and their low sensitivity (approximately 10(4) Gy for an optical density of 1.0). The foils have been evaluated on a He-Ne scanning laser densitometer with a resolution of 0.3 mum. Comparison with NIST (formerly NBS) extrapolation ionization chamber measurements indicates surface dose-rate agreement within 6%. Spectral dosimetric characteristics are presented and discussed

  11. Micro-battery Development using beta radioisotope

    International Nuclear Information System (INIS)

    Jung, H. K.; Cheong, Y. M.; Lee, N. H.; Choi, Y. S.; Joo, Y. S.; Lee, J. S.; Jeon, B. H.

    2007-06-01

    Nuclear battery which use the beta radiation sources emitting the low penetration radiation energy from radioisotope can be applied as the long term (more than 10 years) micro power source in MEMS and nano components. This report describes the basic concept and principles of nuclear micro-battery and its fabrication in space and military field. In particular direct conversion method is described by investigating the electron-hole generation and recombination in p-n junction of silicon betavoltaics with beta radiation

  12. A beta skin dose monitor using an Eberline RO-2 ion chamber

    International Nuclear Information System (INIS)

    Jester, W.A.; Levine, S.H.; Lin, T.J.; Hock, R.

    1994-01-01

    The authors have developed a portable beta skin dose monitor that uses an Eberline RO-2trademark ion chamber. The development was based, in part, upon the previous development of a beta skin dose monitor employing silicon detectors. In this current work, the two entrance windows of the RO-2 were replaced by windows having a total mass thickness of 1.74 mg/cm 2 . A two section source-detector holder was constructed. One section fastens to the RO-2 and holds the detector at the right position to determine the contact skin dose from beta emitters located on surfaces. A second section attaches to the first, and provides fixed counting geometry for radioactive samples such as hot particles. The first section also contains a slide mechanism that allows the placement of absorbers of zero (0), 8.38, and 1000 mg/cm 2 between the detector window and the beta source. The detector response to these absorbers allows for the determination of beta skin dose. The system was modeled using a Monte Carlo beta attenuation code computing the beta skin dose to RO-2 detector response as a function of absorber thickness, average beta energy, source diameter and source position. Using the RO-2 reading from each of the three absorber configurations allows the calculation of beta skin dose and the average beta energy. The results of these calculations were confirmed through the use of three massless radioactive beta sources, traceable to the National Institute of Standards and Technology, and several utility-supplied hot particles having well-established contact skin doses. An extrapolation chamber was also used to confirm the results obtained from this monitor. This system is now use at the Pennsylvania Power and Light (PP and L) Company, the project sponsor. ((orig.))

  13. Multiple Beta Spectrum Analysis Method Based on Spectrum Fitting

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Uk Jae; Jung, Yun Song; Kim, Hee Reyoung [UNIST, Ulsan (Korea, Republic of)

    2016-05-15

    When the sample of several mixed radioactive nuclides is measured, it is difficult to divide each nuclide due to the overlapping of spectrums. For this reason, simple mathematical analysis method for spectrum analysis of the mixed beta ray source has been studied. However, existing research was in need of more accurate spectral analysis method as it has a problem of accuracy. The study will describe the contents of the separation methods of the mixed beta ray source through the analysis of the beta spectrum slope based on the curve fitting to resolve the existing problem. The fitting methods including It was understood that sum of sine fitting method was the best one of such proposed methods as Fourier, polynomial, Gaussian and sum of sine to obtain equation for distribution of mixed beta spectrum. It was shown to be the most appropriate for the analysis of the spectrum with various ratios of mixed nuclides. It was thought that this method could be applied to rapid spectrum analysis of the mixed beta ray source.

  14. Generation of Transplantable Beta Cells for Patient-Specific Cell Therapy

    Directory of Open Access Journals (Sweden)

    Xiaojie Wang

    2012-01-01

    Full Text Available Islet cell transplantation offers a potential cure for type 1 diabetes, but it is challenged by insufficient donor tissue and side effects of current immunosuppressive drugs. Therefore, alternative sources of insulin-producing cells and isletfriendly immunosuppression are required to increase the efficiency and safety of this procedure. Beta cells can be transdifferentiated from precursors or another heterologous (non-beta-cell source. Recent advances in beta cell regeneration from somatic cells such as fibroblasts could circumvent the usage of immunosuppressive drugs. Therefore, generation of patient-specific beta cells provides the potential of an evolutionary treatment for patients with diabetes.

  15. Elaboration of Co-60 sources on gilding vyns, with beta efficiencies 80 % or better and its activity measure by the coincidences method

    International Nuclear Information System (INIS)

    Cortes P, A.; Tejera R, A.; Becerril V, A.; Ortiz C, A.

    1991-12-01

    The measuring technique of radioactive activity by the coincidences method 4 π β - γ it requires of the elaboration of radioactive sources on thin supports in order to flows the biggest percentage of beta particles, those of the order of the 80 % or but. In this work a procedure for the elaboration of this type of sources, with gilding Vyns is reported. (Author)

  16. Elaboration of Co-60 sources on gilding vyns, with beta efficiencies 80 % or better and its activity measure by the coincidences method; Elaboracion de fuentes de Co-60 sobre vyns dorado, con eficiencias beta del 80 % o mejor y su medida de actividad por el metodo de coincidencias

    Energy Technology Data Exchange (ETDEWEB)

    Cortes P, A.; Tejera R, A.; Becerril V, A.; Ortiz C, A

    1991-12-15

    The measuring technique of radioactive activity by the coincidences method 4 {pi} {beta}{sup -} {gamma} it requires of the elaboration of radioactive sources on thin supports in order to flows the biggest percentage of beta particles, those of the order of the 80 % or but. In this work a procedure for the elaboration of this type of sources, with gilding Vyns is reported. (Author)

  17. Calibration of TLD cards to beta ray spectra of 32P

    International Nuclear Information System (INIS)

    Ben-Shachar, B.; German, U.; Naim, E.

    1994-01-01

    The results of the evaluation of TLD chips are received in nC, and we need to transform these values to mGy, in order to obtain the penetrating and the non-penetrating dose. The calibration factors were determined experimentally by irradiation the TLD chips with an uranium source. Beta rays having other spectra can cause incorrect values when estimating the non-penetrating dose. If the spectrum of the beta source is known, a specific evaluation of the calibration factor can be performed. In this report, the estimation of the calibration factor for a 32 P source is presented. LiF:Ti,Mg TLD cards were irradiated calibrated source of 90 Sr/ 90 Y and 204 Tl and non-calibrated source of 32 P, in order to find the beta correction factor for the spectrum of 32 P. Calculations of the beta correction factor were performed too, by applying the Loevinger equations to the geometry of the TLD chips used in our routine measurements. The calculated values of the beta correction factors are lower than the experimental ones. When comparing the ratios, between the beta factors of 32 P and 90 Sr/ 90 Y received from the experiments and from the calculation, we found them to be constant up to ±5%. (authors) 15 refs, 2 figs, 6 tabs

  18. MINIMUM VARIANCE BETA ESTIMATION WITH DYNAMIC CONSTRAINTS,

    Science.gov (United States)

    developed (at AFETR ) and is being used to isolate the primary error sources in the beta estimation task. This computer program is additionally used to...determine what success in beta estimation can be achieved with foreseeable instrumentation accuracies. Results are included that illustrate the effects on

  19. Absolute measurement of {beta} activities and application to the determination of neutronic densities; Mesure absolue d'activites {beta} et application a la determination des densites neutronique

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, R [Commissariat a l' Energie Atomique, Lab. du Fort de Chatillon, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1951-01-15

    M. Berthelot, to my entrance to the ''Commissariat a l 'Energie Atomique'', proposed me to study the absolute measurement of neutron densities. Very quickly the problem of the absolute activity of {beta} sources became the central object of this work. In a first part, we will develop the methods of absolute determination for {beta} activities. The use of a 4{pi} counter permits to get the absolute activity of all beta radioactive source, susceptible to be put as thin leaf and of period superior than some minutes. The method is independent of the spectra of the measured radioelement. we will describe in the second part some applications which use neutron densities measurement, neutron sources intensities and ratio of cross sections of capture of thermal neutrons. (M.B.) [French] M. Berthelot, a mon entree au ''Commissariat a l 'Energie Atomique'', m'a propose d'etudier la mesure absolue des densites neutroniques. Tres rapidement le probleme de l'activite absolue des sources beta est devenu l'objet central de ce travail. Dans une premiere partie, on abordera les methodes de determination absolue des activites beta. L'utilisation d'un compteur 4{pi} permet d 'obtenir l'activite absolue de toute source radioactive beta, susceptible d'etre mise sous forme de feuille mince et de periode superieure a quelques minutes. La methode est independante du spectre du radioelement mesure. On decrira dans la seconde partie quelques applications a des mesures de densites neutroniques, d'intensites de sources de neutrons et de rapport de sections efficaces de capture de neutrons thermiques. (M.B.)

  20. Theoretical study, and construction, of a spherical electrostatic beta spectrometer; Etude theorique et realisation d'un spectrometre beta electrostatique spherique

    Energy Technology Data Exchange (ETDEWEB)

    Moret, R [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1964-03-15

    After a literature survey showing the importance of an electrostatic spectrometer with spherical electrodes for studying disintegration processes, the theoretical characteristics of such an apparatus are derived (determination of the trajectory equations calculation of the transmission and of the resolving power the case of a point source and of an extended source). The apparatus built as a result of these calculations is described. The electrostatic field distribution outside the electrodes is derived. As well as giving electron spectra ({beta} disintegration and conversion electrons) the apparatus make s it possible to study e-{gamma}, e-{beta}, e-e-{gamma} and e-e-{beta} coincidences. In the last part are given experimental characteristics and the results of the first measurements made on conversion electron spectra ({sup 161}Tb, {sup 151}Pm, {sup 155}Eu) and on coincidences ({sup 170}Tm) using this spectrometer. (author) [French] Apres une etude bibliographique montrant l'interet que presente un spectrometre electrostatique a electrodes spheriques pour l'etude des schemas de desintegration, l'auteur etablit les caracteristiques theoriques d'un tel appareil (determination de l'equation des trajectoires calcul de la transmission et du pouvoir de resolution cas d'une source ponctuelle et d'une source etendue). On decrit l'appareil realise d'apres ces calculs. On etablit la repartition du champ electrostatique a l'exterieur des electrodes. Outre le trace des spectres d'electrons (desintegration {beta} et electrons de conversion), l'appareil permet l'etude de coincidences e-{gamma}, e-{beta}, e-e-{gamma} and e-e-{beta}. Dans la derniere partie, sont donnees les caracteristiques experimentales et les premieres etudes de spectres d'electrons de conversion ({sup 161}Tb, {sup 151}Pm, {sup 155}Eu) et de coincidences ({sup 170}Tm) faites a l'aide de ce spectrometre. (auteur)

  1. MetroBeta: Beta Spectrometry with Metallic Magnetic Calorimeters in the Framework of the European Program of Ionizing Radiation Metrology

    Science.gov (United States)

    Loidl, M.; Beyer, J.; Bockhorn, L.; Enss, C.; Györi, D.; Kempf, S.; Kossert, K.; Mariam, R.; Nähle, O.; Paulsen, M.; Rodrigues, M.; Schmidt, M.

    2018-05-01

    MetroBeta is a European project aiming at the improvement of the knowledge of the shapes of beta spectra, both in terms of theoretical calculations and measurements. It is part of a common European program of ionizing radiation metrology. Metallic magnetic calorimeters (MMCs) with the beta emitter embedded in the absorber have in the past proven to be among the best beta spectrometers, in particular for low-energy beta transitions. Within this project, new designs of MMCs optimized for five different beta energy ranges were developed. A new detector module with thermal decoupling of MMC and SQUID chips was designed. An important aspect of the research and development concerns the source/absorber preparation techniques. Four beta spectra with maximum energies ranging from 76 to 709 keV will be measured. Improved theoretical calculation methods and complementary measurement techniques complete the project.

  2. Beta induced Bremsstrahlung dose rate in concrete shielding

    International Nuclear Information System (INIS)

    Manjunatha, H.C.

    2013-01-01

    Dosimetric study of beta-induced Bremsstrahlung in concrete is importance in the field of radiation protection. The efficiency, intensity and dose rate of beta induced Bremsstrahlung by 113 pure beta nuclides in concrete shielding is computed. The Bremsstrahlung dosimetric parameters such as the efficiency (yield), Intensity and dose rate of Bremsstrahlung are low for 199 Au and high for 104 Tc in concrete. The efficiency, Intensity and dose rate of Bremsstrahlung increases with maximum energy of beta nuclide (Emax) and modified atomic number (Zmod) of the target. The estimated Bremsstrahlung efficiency, Intensity and dose rate are useful in the calculations photon track-length distributions. These parameters are useful to determine the quality and quantity of the radiation (known as the source term). Precise estimation of this source term is very important in planning of radiation shielding. (author)

  3. The need for international standardization in clinical beta dosimetry for brachytherapy

    International Nuclear Information System (INIS)

    Quast, U.; Boehm, J.; Kaulich, T.W.

    2002-01-01

    Beta radiation has found increasing interest in radiotherapy. Besides the curative treatment of small and medium-sized intraocular tumors by means of ophthalmic beta radiation plaques, intravascular brachytherapy has proven to successfully overcome the severe problem of restenosis after interventional treatment of arterial stenosis in coronaries and peripheral vessels in many clinical trials with a large number of patients. Prior to initiating procedures applying beta radiation in radiotherapy, however, there is a common need to specify methods for the determination and specification of the absorbed dose to water or tissue and their spatial distributions. The IAEA-TECDOC-1274 Calibration of photon and beta ray sources used in brachytherapy (2002) is a help for photon brachytherapy calibration. But, for beta seed and line sources, IAEA recommends well type ionization chambers as working standards which are far from measuring absorbed dose to water of the radiation clinically used. Although the application of such working standards seems to be more precise, large errors can occur when the medical physicist has to convert the calibration data to absorbed dose to water of the beta radiation emitted. The user must believe that the source is equally activated and that the manufacturer did not change the design and construction of the source encapsulation. With the DGMP Report 16 (2001) Guidelines for medical physical aspects of intravascular brachytherapy a very detailed code of practice is given, especially for the calibration and clinical dosimetry of intravascular beta radiation sources. As there is a global need for standardization in clinical dosimetry for intravascular brachytherapy utilizing beta radiation, the DIN-NAR, the German committee on standardization in radiology, task group dosimetry, has initiated an international adhoc working group for a new ISO work item proposal on the standardization of procedures in clinical dosimetry to guarantee reliable

  4. Field measurement and interpretation of beta doses and dose rates

    International Nuclear Information System (INIS)

    Selby, J.M.; Swinth, K.L.; Hooker, C.D.; Kenoyer, J.L.

    1983-01-01

    A wide variety of portable survey instruments employing GM, ionization chamber and scintillation detectors exist for the measurement of gamma exposure rates. Often these same survey instruments are used for monitoring beta fields. This is done by making measurements with and without a removable shield which is intended to shield out the non-penetrating component (beta) of the radiation field. The difference does not correspond to an absorbed dose rate for the beta field due to a variety of factors. Among these factors are the dependence on beta energy, source-detector geometries, mixed fields and variable ambient conditions. Attempting to use such measurements directly can lead to errors as high as a factor of 100. In many instances correction factors have been derived, that if properly applied, can reduce these errors substantially. However, this requires some knowledge of the beta spectra, calibration techniques and source geometry. This paper discusses some aspects of the proper use of instruments for beta measurements including the application of appropriate correction factors. Ionization type instruments are commonly used to measure beta dose rates. Through design and calibration these instruments will give an accurate reading only for uniform irradiation of the detection volume. Often in the field it is not feasible to meet these conditions. Large area uniform distributions of activity are not generally encountered and it is not possible to use large source-to-detector distances due to beta particle absorption in air. An example of correction factors required for various point sources is presented when a cutie pie ionization chamber is employed. The instrument reading is multiplied by the appropriate correction factor to obtain the dose rate at the window. When a different detector is used or for other geometries, a different set of correction factors must be used

  5. Beta ray backscattering studies for thickness measurements

    Energy Technology Data Exchange (ETDEWEB)

    Singh, M; Sharma, K K [Punjabi Univ., Patiala (India). Nuclear Science Labs.

    1979-01-01

    Back-scattering of beta rays from /sup 204/Tl (Esub(..beta..)max = 740 keV) and /sup 90/Sr-/sup 90/Y (Esub(..beta..)max =550 and 2250 keV) has been studied in an improved reflection geometry, using annular sources, from a number of elemental targets with Z values ranging from 13 to 82. Source to target and target to detector geometry factors are 0.0225 and 0.0282 respectively. Values of saturation back scattering thickness obtained in the two cases are 72 +- 10 and 190 +- 40 mg/cm/sup 2/ respectively. It is observed that the intensity of back scattered radiation varies linearly with thickness upto a value of 12 +- 2 mg/cm/sup 2/ in /sup 204/Tl and 17 +- 3 mg/cm/sup 2/ in /sup 90/Sr-/sup 90/Y.

  6. Methodology to determine the efficiency of a beta emitter gases monitor; Metodologia para determinacao da eficiencia de um monitor de gases emissores de particulas beta

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, Marcos Rodrigues de

    1995-07-01

    This work presents a methodology developed to determinate the efficiency of air monitors used to measure the concentration of beta emitters noble gases in nuclear power stations. Efficiency values, obtained by means of theoretical computation are compared with experimental values. The experimental part of the work was performed using three different point beta source, to simulate small amounts of gas uniformly distributed in small volume. The comparison shows that theoretical an experimental values agree within 4,2 % for {sup 90}Sr + {sup 90}Y, {sup 204}Tl and {sup 45}Ca beta sources. (author)

  7. Absolute measurement of {beta} activities and application to the determination of neutronic densities; Mesure absolue d'activites {beta} et application a la determination des densites neutronique

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, R. [Commissariat a l' Energie Atomique, Lab. du Fort de Chatillon, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1951-01-15

    M. Berthelot, to my entrance to the ''Commissariat a l 'Energie Atomique'', proposed me to study the absolute measurement of neutron densities. Very quickly the problem of the absolute activity of {beta} sources became the central object of this work. In a first part, we will develop the methods of absolute determination for {beta} activities. The use of a 4{pi} counter permits to get the absolute activity of all beta radioactive source, susceptible to be put as thin leaf and of period superior than some minutes. The method is independent of the spectra of the measured radioelement. we will describe in the second part some applications which use neutron densities measurement, neutron sources intensities and ratio of cross sections of capture of thermal neutrons. (M.B.) [French] M. Berthelot, a mon entree au ''Commissariat a l 'Energie Atomique'', m'a propose d'etudier la mesure absolue des densites neutroniques. Tres rapidement le probleme de l'activite absolue des sources beta est devenu l'objet central de ce travail. Dans une premiere partie, on abordera les methodes de determination absolue des activites beta. L'utilisation d'un compteur 4{pi} permet d 'obtenir l'activite absolue de toute source radioactive beta, susceptible d'etre mise sous forme de feuille mince et de periode superieure a quelques minutes. La methode est independante du spectre du radioelement mesure. On decrira dans la seconde partie quelques applications a des mesures de densites neutroniques, d'intensites de sources de neutrons et de rapport de sections efficaces de capture de neutrons thermiques. (M.B.)

  8. Laser and beta source setup characterization of 3D-DDTC detectors fabricated at FBK-irst

    Energy Technology Data Exchange (ETDEWEB)

    Zoboli, A. [INFN, Sezione di Padova (Gruppo Collegato di Trento), and Dipartimento di Ingegneria e Scienza dell' Informazione, Universita di Trento, Via Sommarive, 14, I-38050 Povo (Trento) (Italy)], E-mail: zoboli@disi.unitn.it; Dalla Betta, G.-F. [INFN, Sezione di Padova (Gruppo Collegato di Trento), and Dipartimento di Ingegneria e Scienza dell' Informazione, Universita di Trento, Via Sommarive, 14, I-38050 Povo (Trento) (Italy); Boscardin, M. [Fondazione Bruno Kessler, Centro per i Materiali e i Microsistemi, Via Sommarive, 18, I-38050 Povo (Trento) (Italy); Bosisio, L. [Dip. di Fisica e INFN, Universita di Trieste, I-34127, Trieste (Italy); Eckert, S.; Kuehn, S.; Parzefall, U. [Institute of Physics, University of Freiburg, Hermann-Herder-Str. 3, 79104 Freiburg (Germany); Piemonte, C.; Ronchin, S.; Zorzi, N. [Fondazione Bruno Kessler, Centro per i Materiali e i Microsistemi, Via Sommarive, 18, I-38050 Povo (Trento) (Italy)

    2009-06-01

    We report on the functional characterization of the first batch of 3D Double-Sided Double Type Column (3D-DDTC) detectors fabricated at FBK, Trento. This detector concept represents the evolution of the previous 3D-STC detectors towards full 3D detectors, and is expected to achieve a performance which is comparable to standard 3D detectors, but with a simpler fabrication process. Measurements were performed on detectors in the microstrip configuration coupled to the ATLAS ABCD3T binary readout. This paper reports spatially resolved signal efficiency tests made with a pulsed infrared laser setup and charge collection efficiency tests made with a Beta source.

  9. Laser and beta source setup characterization of 3D-DDTC detectors fabricated at FBK-irst

    International Nuclear Information System (INIS)

    Zoboli, A.; Dalla Betta, G.-F.; Boscardin, M.; Bosisio, L.; Eckert, S.; Kuehn, S.; Parzefall, U.; Piemonte, C.; Ronchin, S.; Zorzi, N.

    2009-01-01

    We report on the functional characterization of the first batch of 3D Double-Sided Double Type Column (3D-DDTC) detectors fabricated at FBK, Trento. This detector concept represents the evolution of the previous 3D-STC detectors towards full 3D detectors, and is expected to achieve a performance which is comparable to standard 3D detectors, but with a simpler fabrication process. Measurements were performed on detectors in the microstrip configuration coupled to the ATLAS ABCD3T binary readout. This paper reports spatially resolved signal efficiency tests made with a pulsed infrared laser setup and charge collection efficiency tests made with a Beta source.

  10. Relation between the 2{nu}{beta}{beta} and 0{nu}{beta}{beta} nuclear matrix elements

    Energy Technology Data Exchange (ETDEWEB)

    Vogel, Petr [Kellogg Radiation Laboratory, Caltech, Pasadena, CA 91125 (United States); Simkovic, Fedor [Department of Nuclear Physics and Biophysics, Comenius University, Mlynska dolina F1, SK-84248 Bratislava (Slovakia)

    2011-12-16

    A formal relation between the GT part of the nuclear matrix elements M{sub GT}{sup 0{nu}} of 0{nu}{beta}{beta} decay and the closure matrix elements M{sub cl}{sup 2{nu}} of 2{nu}{beta}{beta} decay is established. This relation is based on the integral representation of these quantities in terms of their dependence on the distance r between the two nucleons undergoing transformation. We also discuss the difficulties in determining the correct values of the closure 2{nu}{beta}{beta} decay matrix elements.

  11. Reference beta radiations for calibrating dosemeters and dose ratemeters and for determining their response as a function of beta radiation energy. 1. ed.

    International Nuclear Information System (INIS)

    1984-01-01

    This International Standard specifies the requirements for reference beta radiations produced by radionuclide sources to be used for the calibration of protection level dosemeters and dose ratemeters, and for the determination of their response as a function of beta energy. It gives the characteristics of radionuclides which have been used to produce reference beta radiations, gives examples of suitable source constructions and describes methods for the measurement of the residual maximum beta energy and the absorbed dose rate at a depth of 7 mg·cm -2 in a semi-infinite tissue-equivalent medium. The energy range involved lies between 66 keV and 3.6 MeV and the absorbed dose rates are in the range from about 10 μGy·h -1 (1 mrad·h -1 ) to at least 10 Gy·h -1 (10 3 rad·h -1 ). This International Standard proposes two series of beta reference radiations from which the radiation necessary for determining the characteristics (calibration and energy response) of an instrument shall be selected. Series 1 reference radiations are produced by radionuclide sources used with beam flattening filters designed to give uniform dose rates over a large area at a specific distance. The proposed sources of 90 Sr+ 90 Y, 204 TI and 147 Pm produce maximum dose rates of approximately 5mGy·h -1 (0.5 rad·h -1 ). Series 2 reference radiations are produced without the use of beam flattening filters which allows a range of source-to-calibration plane distances to be used. Close to the sources only relatively small areas of uniform dose rate are produced but this Series has the advantage of extending the energy and dose rate ranges beyond those of Series 1. The radionuclides used are those of Series 1 with the addition of the radionuclides 14 C and 106 Ru+ 106 Rh; these sources produce dose rates of up to 10 Gy·h -1 (10 3 rad·h -1 )

  12. Methodology to determine the efficiency of a beta emitter gases monitor

    International Nuclear Information System (INIS)

    Carvalho, Marcos Rodrigues de

    1995-01-01

    This work presents a methodology developed to determinate the efficiency of air monitors used to measure the concentration of beta emitters noble gases in nuclear power stations. Efficiency values, obtained by means of theoretical computation are compared with experimental values. The experimental part of the work was performed using three different point beta source, to simulate small amounts of gas uniformly distributed in small volume. The comparison shows that theoretical an experimental values agree within 4,2 % for 90 Sr + 90 Y, 204 Tl and 45 Ca beta sources. (author)

  13. Design and dosimetry of a novel 90y beta source to prevent restenosis after angioplasty

    International Nuclear Information System (INIS)

    Mueck, Konrad; Schmidt, Werner; Wexberg, Paul; Goerz, Walter; Maurer, Gerald; Gottsauner-Wolf, Michael

    2000-01-01

    Purpose: Post-dilatation irradiation of the vessel wall is currently under investigation for prevention of restenosis after balloon dilatation. For the irradiation, special sources were designed for animal experiments which would give equivalent irradiation conditions and doses to the vessel wall that would later be employed for human application. Methods and Materials: For the planned irradiations, a specially designed yttrium-wire of 0.45-mm diameter coated with a thin shrink tube to prevent contamination was deployed. Several leakage tests applied before and after application proved that the irradiation source was leakproof. Dosimetry was performed by using 0.1-mm-thick thermoluminescent dosimeters (TLD-100) calibrated against a primary standard. A shielding transport and application container was designed to facilitate the handling of the source during use, while reducing exposure of the medical personnel. Results: The designed source proves to be flexible for the insertion into proximal coronary vessels, and positioning at the site of stenosis. It provides an optimum protection of the animal and requires little radiation protection efforts on behalf of the medical staff. Dosimetric calculations and measurements showed that a centering of the source inside the vessel could be achieved with a maximum deviation of 50% between maximum and average dose levels. Conclusion: A yttrium-90 beta brachytherapy source was designed which provides high flexibility within proximal coronary arteries, ensures an adequate centering inside the artery, and provides irradiation conditions to the vessel wall of the experimental animal comparable to the application inside a human artery

  14. A Novel Dimeric Inhibitor Targeting Beta2GPI in Beta2GPI/Antibody Complexes Implicated in Antiphospholipid Syndrome

    Energy Technology Data Exchange (ETDEWEB)

    A Kolyada; C Lee; A De Biasio; N Beglova

    2011-12-31

    {beta}2GPI is a major antigen for autoantibodies associated with antiphospholipid syndrome (APS), an autoimmune disease characterized by thrombosis and recurrent pregnancy loss. Only the dimeric form of {beta}2GPI generated by anti-{beta}2GPI antibodies is pathologically important, in contrast to monomeric {beta}2GPI which is abundant in plasma. We created a dimeric inhibitor, A1-A1, to selectively target {beta}2GPI in {beta}2GPI/antibody complexes. To make this inhibitor, we isolated the first ligand-binding module from ApoER2 (A1) and connected two A1 modules with a flexible linker. A1-A1 interferes with two pathologically important interactions in APS, the binding of {beta}2GPI/antibody complexes with anionic phospholipids and ApoER2. We compared the efficiency of A1-A1 to monomeric A1 for inhibition of the binding of {beta}2GPI/antibody complexes to anionic phospholipids. We tested the inhibition of {beta}2GPI present in human serum, {beta}2GPI purified from human plasma and the individual domain V of {beta}2GPI. We demonstrated that when {beta}2GPI/antibody complexes are formed, A1-A1 is much more effective than A1 in inhibition of the binding of {beta}2GPI to cardiolipin, regardless of the source of {beta}2GPI. Similarly, A1-A1 strongly inhibits the binding of dimerized domain V of {beta}2GPI to cardiolipin compared to the monomeric A1 inhibitor. In the absence of anti-{beta}2GPI antibodies, both A1-A1 and A1 only weakly inhibit the binding of pathologically inactive monomeric {beta}2GPI to cardiolipin. Our results suggest that the approach of using a dimeric inhibitor to block {beta}2GPI in the pathological multivalent {beta}2GPI/antibody complexes holds significant promise. The novel inhibitor A1-A1 may be a starting point in the development of an effective therapeutic for antiphospholipid syndrome.

  15. On the influence of the finite thickness of sources on the internal conversion lines observed in beta spectrometer

    International Nuclear Information System (INIS)

    Pecequilo, B.R.S.

    1976-01-01

    Electron lines are simulated by a Monte Carlo method in a digital computer in order to obtain an analytical formula to calculate the energy and the relative intensity of electron conversion lines when observed by beta spectrometry. The electrons come from the own thickness of the source. Computer program that simulate these lines is presented. In order to test the method, a direct comparison of the K-line of Hg-198 with the same line as simulated by the computer, is done [pt

  16. T-odd momentum correlation in radiative {beta} decay

    Energy Technology Data Exchange (ETDEWEB)

    Gardner, Susan, E-mail: gardner@pa.uky.edu; He, Daheng [University of Kentucky, Department of Physics and Astronomy (United States)

    2013-03-15

    The triple-product correlations observable in ordinary neutron or nuclear beta decay are all naively T violating and can connect, through an assumption of CPT invariance, to constraints on sources of CP violation beyond the Standard Model. They are also spin dependent. In this context the study of radiative beta decay opens a new possibility, in that a triple-product correlation can be constructed from momenta alone. Consequently its measurement would constrain new spin-independent sources of CP violation. We will describe these in light of the size of the triple momentum correlation in the decay rate arising from electromagnetic final-state interactions in the Standard Model. Our expression for the corresponding T-odd asymmetry is exact in O({alpha}) up to terms of recoil order, and we evaluate it numerically under various kinematic conditions. We consider the pattern of the asymmetries in nuclear {beta} decays and show that the asymmetry can be suppressed in particular cases, facilitating searches for new sources of CP violation in such processes.

  17. Purification and properties of beta-galactosidase from Aspergillus nidulans.

    Science.gov (United States)

    Díaz, M; Pedregosa, A M; de Lucas, J R; Torralba, S; Monistrol, I F; Laborda, F

    1996-12-01

    Beta-Galactosidase from mycelial extract of Aspergillus nidulans has been purified by substrate affinity chromatography and used to obtain anti-beta-galactosidase polyclonal antibodies. A. nidulans growing in lactose as carbon source synthesizes one active form of beta-galactosidase which seems to be a multimeric enzyme of 450 kDa composed of monomers with 120 and 97 kDa. Although the enzyme was not released to the culture medium, some enzymatic activity was detected in a cell-wall extract, thus suggesting that it can be an extracellular enzyme. Beta-Galactosidase of A. nidulans is a very unstable enzyme with an optimum pH value of 7.5 and an optimum temperature of 30 degrees C. It was only active against beta-galactoside substrates like lactose and p-nitrophenyl-beta-D-galactoside (PNPG).

  18. Proposal of a dosemeter for skin beta radiation dose assessment

    International Nuclear Information System (INIS)

    Rosa, L.A.R. da; Caldas, L.V.E.

    1987-08-01

    Beta radiation is, undoubtedly, less penetrating than X or gamma radiation. Thus, beta radiation sources external to the human body do not cause a significant irradiation of its deeper tissues. However, in some cases, they may contribute in a very important way to the irradiation of the lens of the eyes and, mainly, of the skin. Specially, the hands and finger tips may receive a high dose. In this work some relevant aspects of the individual monitoring in beta radiation fields are discussed and the importance of monitoring this kind of radiation in some activities where the skin absorbed dose may be a limiting factor is evidenced. The main characteristics of the thermoluminescent (TL) response of ultra-thin CaSO 4 : Dy detectors (UT-CaSO 4 : Dy) in the detection of this kind of radiation are also studied. The irradiation are performed with 90 Sr 90 Y, 204 TI and 147 Pm sources. The reproducibility, linearity, dependence on the absorbed dose rate, optical fading, energy and angular dependences of the detector TL responce are investigated. Transmission factors for different thicknesses of tissue equivalent material are obtained for the TL detectors using the three available beta sources. Based on the results obtained, a dosemeter for skin beta radiation absorbed dose assessment with an energy dependence better than 12% is proposed. (Author) [pt

  19. Energy response of an imaging plate exposed to standard beta sources

    International Nuclear Information System (INIS)

    Gonzalez, A.L.; Li, H.; Mitch, M.; Tolk, N.; Duggan, D.M.

    2002-01-01

    Imaging plates (IPs) are a reusable media, which when exposed to ionizing radiation, store a latent image that can be read out with a red laser as photostimulated luminescence (PSL). They are widely used as a substitute for X-ray films for diagnostic studies. In diagnostic radiology this technology is known as computed radiography. In this work, the energy response of a commercial IP to beta-particle reference radiation fields used for calibrations at the National Institute of Standards and Technology was investigated. The absorbed dose in the active storage phosphor layer was calculated following the scaling procedure for depth dose for high Z materials with reference to water. It was found that the beta particles from Pm-147 and Kr-85 gave 68% and 24% higher PSL responses than that induced by Sr-90, respectively, which was caused by the different PSL detection efficiencies. In addition, normalized response curves of the IPs as a function of depth in polystyrene were measured and compared with the data measured using extrapolation chamber techniques. The difference between both sets of data resulted from the continuous energy change as the beta particle travels across the material, which leads to a different PSL response

  20. 4{pi} proportional counter for absolute measurement of {beta}-emitters; Compteur 4{pi} proportionnel destine a la mesure absolue d'emetteurs {beta}

    Energy Technology Data Exchange (ETDEWEB)

    Perolat, J P; Laine, M [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-07-01

    The 4{pi} counter is commonly used to measure the activity of {beta} sources, the one we describe does not advance a new conception but the issue of several years of investigations. The apparatus presents good performances about the qualities commonly required in that kind of counter: detection efficiency, plateau and dead time. Moreover technical characteristics give a great flexibility in use, particularly a possibility of adaptation in a {beta},{gamma} coincidence unit. (authors) [French] Le compteur 4{pi} proportionnel est couramment, utilise pour mesurer l'activite de sources {beta}, celui que nous decrivons ne represente pas une conception nouvelle, mais plutot l'aboutissement de plusieurs annees d'etudes. Cette installation presente des performances satisfaisantes en ce qui concerne les qualites habituellement requises dans ce type de compteur: l'efficacite de detection, le palier et le temps mort. En outre, certaines caracteristiques techniques qui lui sont propres lui conferent une grande souplesse d'utilisation, en particulier la possibilite d'adaptation a un ensemble de mesures par coincidences 4{pi} {beta} {gamma}. (auteurs)

  1. A method of preserving and testing the acceptability of gac fruit oil, a good source of beta-carotene and essential fatty acids.

    Science.gov (United States)

    Vuong, L T; King, J C

    2003-06-01

    Gac fruit (Momordica cochinchinensis Spreng) is indigenous to Vietnam and other countries in Southeast Asia. Its seed pulp contains high concentrations of carotenoids, especially the provitamin A, beta-carotene. In northern Vietnam, gac fruits are seasonal and are mainly used in making a rice dish called xoi gac. The purpose of this study was to develop a method to collect and preserve gac fruit oil, to evaluate the nutritional composition of the oil, and to assess the acceptability of the gac oil by typical Vietnamese homemakers. One hundred women participated in training to learn how to prepare the fruits and operate the oil press. The women also participated in a survey of gac fruit use and their habitual use of animal fat and vegetable oil. Among all the participants in the training and surveys, 35 women actually produced oil from gac fruits grown in the village, using manual oil presses and locally available materials. The total carotene concentration in gac fruit oil was 5,700 micrograms/ml. The concentration of beta-carotene was 2,710 micrograms/ml. Sixty-nine percent of total fat was unsaturated, and 35% of that was polyunsaturated. The average daily consumption of gac fruit oil was estimated at 2 ml per person. The daily beta-carotene intake (from gac fruit oil) averaged approximately 5 mg per person. It was found that gac oil can be produced locally by village women using manual presses and locally available materials. The oil is a rich source of beta-carotene, vitamin E, and essential fatty acids. Although the beta-carotene concentration declines with time without a preservative or proper storage, it was still high after three months. The oil was readily accepted by the women and their children, and consumption of the oil increased the intake of beta-carotene and reduced the intake of lard.

  2. Pulse shape analyzer/timing-SCA application to beta measurement

    International Nuclear Information System (INIS)

    Selvi, S.; Celiktas, C.

    2001-01-01

    Electrical noise contribution to pulse height distributions from beta sources due to BC-400 plastic scintillator(PS), preamplifier and spectroscopy amplifier was rejected by setting the electronic set-up processing of the modified beta spectrometer consisted of pulse shape analyzer/timing single channel analyzer (PSA/SCA) and related complementary equipments. Improved noise rejection performance was evaluated in terms of elimination practically only all of the noise band of C-14 and Tl-204 spectra obtained using the two alternate beta spectrometer

  3. Dosimetric characteristics of the Novoste Beta-Cath 90Sr/Y source trains at submillimeter distances

    International Nuclear Information System (INIS)

    Roa, Dante E.; Song Haijun; Yue Ning; D'Errico, Francesco; Nath, Ravinder

    2004-01-01

    Measurements were performed on the 30, 40, and 60 mm 90 Sr/Y β-emitter source trains used in the Novoste Beta-Cath system to determine their dosimetric characteristics at submillimeter distances and provide the necessary TG-60 parameters for mapping their dose distributions. These measurements were carried out in a Solid Water TM phantom where MD55-2 Gafchromic TM films were placed in direct contact with a 5 French (F) catheter used for the 30 and 60 mm source trains and a 3.5F catheter used for thinner 30 and 40 mm source trains. A data set consisted of three pieces of Gafchromic film irradiated for periods of 1.5, 5, and 10 minutes, respectively. This 3-film irradiation technique provided reliable dose data at short, intermediate and long distances from a source train. Three data sets per source train were collected in this study. For the 30 mm source train with a 5F catheter, data were collected with the source axis at proximal (0.41 mm) and distal (1.19 mm) positions to the film surface in order to investigate dosimetric effects due to the off centering of the source train lumen within the catheter. Absolute doses were determined by calibrating the Gafchromic film in a high-energy electron beam from a radiotherapy accelerator. The absolute dose rates at a distance of 2 mm along the source trains transverse axis were found to be within 13.7% of the values provided by Novoste. Radial dose functions were within 13% compared to 90 Sr/Y source train data constructed from Soares' 90 Sr/Y single seed data and within 17% and 25% compared to Monte Carlo data by Ye et al., and Wang et al., respectively. Discrepancies of 33% and 19% were observed at short radial distances (≤1 mm) between the Novoste Monte Carlo and the 3.5F and 5F catheter measured data, respectively. The source off centering data showed higher dose contribution from the source train at its distal rather than proximal position. Radial dose function comparisons between the Novoste Monte Carlo and the

  4. Beta-decay of {sup 56}Cu

    Energy Technology Data Exchange (ETDEWEB)

    Ramdhane, M.; Baumann, P.; Knipper, A.; Walter, G. [Institute de Recherches Subatomiques, 67 - Strasbourg (France); Janas, Z.; Plochocki, A. [Warsaw Univ. (Poland). Inst. of Experimental Physics; Aeystoe, J.; Dendooven, P.; Jokinen, A.; Oinonen, M.; Pentilae, H. [Jyvaeskylae Univ. (Finland); Liu, W.; Grawe, H.; Hu, Z.; Kirchner, R.; Klepper, O.; Roeckl, E. [Gesellschaft fuer Schwerionenforschung mbH, Darmstadt (Germany); Gorska, M. [Warsaw Univ. (Poland). Inst. of Experimental Physics]|[Gesellschaft fuer Schwerionenforschung mbH, Darmstadt (Germany); Fujita, Y. [Osaka Univ. (Japan); Brown, B.A. [Michigan State Univ., East Lansing, MI (United States)

    1998-02-01

    By measuring positrons and {beta}-delayed {gamma}-rays emitted from mass-separated sources, the decay of {sup 56}Cu(4{sup +},T{sub z}=-1,T=1) to states in the doubly-magic nucleus {sup 56}Ni was studied for the first time. The half-life of {sup 56}Cu was measured to be 78(15) ms, and four {beta}-delayed {gamma}-rays were assigned to its decay. The resulting experimental data on Fermi and Gamow-Teller strength are compared with shell-model predictions. (orig.)

  5. Beta Beams for Precision Measurements of Neutrino Oscillation Parameters

    CERN Document Server

    Wildner, E; Hansen, C; De Melo Mendonca, T; Stora, T; Damjanovic, S; Payet, J; Chancé, A; Zorin, V; Izotov, I; Rasin, S; Sidorov, A; Skalyga, V; De Angelis, G; Prete, G; Cinausero, M; Kravchuk, V; Gramegna, F; Marchi, T; Collazuol, G; Mezzetto, M; Delbar, T; Loiselet, M; Keutgen, T; Mitrofanov, S; Burt, G; Dexter, A; Lamy, T; Latrasse, L; Marie-Jeanne, M; Sortais, P; Thuillier, T; Debray, F; Trophime, C; Hass, M; Hirsh, T; Berkovits, D; Stahl, A; Vardaci, E; Di Nitto, A; Brondi, A; La Rana, G; Moro, R; De Rosa, G; Palladino, V

    2012-01-01

    Neutrino oscillations have implications for the Standard Model of particle physics. The CERN Beta Beam has outstanding capabilities to contribute to precision measurements of the parameters governing neutrino oscillations. The FP7 collaboration EUROnu (2008-2012) is a design study that will review three facilities (Super-Beams, Beta Beams and Neutrino Factories) and perform a cost assessment that, coupled with the physics performance, will give means to the European research authorities to make decisions on future European neutrino oscillation facilities. ”Beta Beams” produce collimated pure electron (anti)neutrinos by accelerating beta active ions to high energies and having them decay in a storage ring. Using existing machines and infrastructure is an advantage for the cost evaluation; however, this choice is also constraining the Beta Beams. Recent work to make the Beta Beam facility a solid option will be described: production of Beta Beam isotopes, the 60 GHz pulsed ECR source development, integratio...

  6. BETA digital beta radiometer

    International Nuclear Information System (INIS)

    Borovikov, N.V.; Kosinov, G.A.; Fedorov, Yu.N.

    1989-01-01

    Portable transportable digital beta radiometer providing for measuring beta-decay radionuclide specific activity in the range from 5x10 -9 up to 10 -6 Cu/kg (Cu/l) with error of ±25% is designed and introduced into commercial production for determination of volume and specific water and food radioactivity. The device specifications are given. Experience in the BETA radiometer application under conditions of the Chernobyl' NPP 30-km zone has shown that it is convenient for measuring specific activity of the order of 10 -8 Cu/kg, and application of a set of different beta detectors gives an opportunity to use it for surface contamination measurement in wide range of the measured value

  7. LHCb: $2\\beta_s$ measurement at LHCb

    CERN Multimedia

    Conti, G

    2009-01-01

    A measurement of $2\\beta_s$, the phase of the $B_s-\\bar{B_s}$ oscillation amplitude with respect to that of the ${\\rm b} \\rightarrow {\\rm c^{+}}{\\rm W^{-}}$ tree decay amplitude, is one of the key goals of the LHCb experiment with first data. In the Standard Model (SM), $2\\beta_s$ is predicted to be $0.0360^{+0.0020}_{-0.0016} \\rm rad$. The current constraints from the Tevatron are: $2\\beta_{s}\\in[0.32 ; 2.82]$ at 68$\\%$CL from the CDF experiment and $2\\beta_{s}=0.57^{+0.24}_{-0.30}$ from the D$\\oslash$ experiment. Although the statistical uncertainties are large, these results hint at the possible contribution of New Physics in the $B_s-\\bar{B_s}$ box diagram. After one year of data taking at LHCb at an average luminosity of $\\mathcal{L}\\sim2\\cdot10^{32}\\rm cm^{-2} \\rm s^{-1}$ (integrated luminosity $\\mathcal{L}_{\\rm int}\\sim 2 \\rm fb^{-1}$), the expected statistical uncertainty on the measurement is $\\sigma(2\\beta_s)\\simeq 0.03$. This uncertainty is similar to the $2\\beta_s$ value predicted by the SM.

  8. Implantation of a new Beta Secondary Standard system at Centro de Desenvolvimento da Tecnologia Nuclear

    International Nuclear Information System (INIS)

    Reynaldo, Sibele Reis

    2005-01-01

    The crescent use of beta radiation sources in medical, industrial and research applications has increased the need for higher accuracy in beta dosimetry. As the first Beta Secondary Standard system (BSS1) was developed about 20 years ago, a new BSS2 system was made commercially available to fulfill new metrological demands and to follow the technological development. The BSS2 has a new positioning set-up, high activity and long half-life beta radiation sources and a special safety system. The Centro de Desenvolvimento da Tecnologia Nuclear is the first laboratory in Latin America that has got a BSS2. This work describes the BSS2 and it compares its advantages in relation to BSS1; results of the beam uniformity tests of the radiation fields from 90 Sr/ 90 Y, 85 Kr and 147 Pm sources, that were measured with an ionization chamber and with thermoluminescent detectors, are also shown. Results show that the beta radiation fields are considered to be uniform for diameters between 8 and 20 cm according to the chosen source. (author)

  9. Current status of personnel monitoring for beta particles

    International Nuclear Information System (INIS)

    Plato, P.; Miklos, J.

    1983-01-01

    From 1975 to 1982, a concerted effort was made to develop a uniform procedure to test the performance of personnel dosimetry processors throughout the United States. The heart of this effort is a standard developed by the Health Physics Society Standards Committee (HPSSC) and adopted by the American National Standards Institute (ANSI) as ANSI N13.11-1982. The US Nuclear Regulatory Commission (NRC) sponsored a five year pilot study of this Standard which included three trial tests in which approximately 80 dosimetry processors participated. The Standard has made several contributions to the art and science of personnel monitoring for beta particles. First, the Standard defines test categories for beta particles and mixtures of beta particles plus gamma rays in addition to test categories for other types of radiation. Second, it defines a reference beta-particle source for test purposes. Third, it provides test criteria which are used to determine acceptable performance by a processor. The pilot study provided information on the state of the art of personnel monitoring within the bounds of the Standard. In addition, since the pilot study was advertised as the forerunner of a future mandatory certification program for dosimetry processors throughout the United States, considerable attention was given to personnel monitoring in general, and beta particles in particular. This paper discusses specific contibutions of the HPSSC/ANSI Standard and the pilot study to beta-particle dosimetry. The results of the three tests of the pilot study are summarized. The paper also amplifies on the needs to define the monitoring particle sources clearly

  10. Calibration of photon and beta ray sources used in brachytherapy. Guidelines on standardized procedures at Secondary Standards Dosimetry Laboratories

    International Nuclear Information System (INIS)

    2004-03-01

    It has generally been recognized that international harmonization in radiotherapy dosimetry is essential. Consequently, the IAEA has given much effort to this, for example by publishing a number of reports in the Technical Reports Series (TRS) for external beam dosimetry, most notably TRS-277 and more recently TRS-398. Both of these reports describe in detail the steps to be taken for absorbed dose determination in water and they are often referred to as 'dosimetry protocols'. Similar to TRS-277, it is expected that TRS-398 will be adopted or used as a model by a large number of countries as their national protocol. In 1996, the IAEA established a calibration service for low dose rate (LDR) 137 Cs brachytherapy sources, which is the most widely used source for treatment of gynecological cancer. To further enhance harmonization in brachytherapy dosimetry, the IAEA published in 1999 IAEA-TECDOC-1079 entitled 'Calibration of Brachytherapy Sources. Guidelines on Standardized Procedures for the Calibration of Brachytherapy Sources at Secondary Standard Dosimetry Laboratories (SSDLs) and Hospitals'. The report was well received and was distributed in a large number of copies to the members of the IAEA/WHO network of SSDLs and to medical physicists working with brachytherapy. The present report is an update of the aforementioned TECDOC. Whereas TECDOC-1079 described methods for calibrating brachytherapy sources with photon energies at or above those of 192 Ir, the current report has a wider scope in that it deals with standardization of calibration of all the most commonly used brachytherapy sources, including both photon and beta emitting sources. The latter sources have been in use for a few decades already, but their calibration methods have been unclear. Methods are also described for calibrating sources used in the rapidly growing field of cardiovascular angioplasty. In this application, irradiation of the vessel wall is done in an attempt to prevent restenosis after

  11. Design and operation of dust measuring instrumentation based on the beta-radiation method

    International Nuclear Information System (INIS)

    Lilienfeld, P.

    1975-01-01

    The theory, instrument design aspects and applications of beta-radiation attenuation for the measurement of the mass concentration of airborne particulates are reviewed. Applicable methods of particle collection, beta sensing configurations, source ( 63 Ni, 14 C, 147 Pr, 85 Kr) and detector design criteria, electronic signal processing, digital control and instrument programming techniques are treated. Advantages, limitations and error sources of beta-attenuation instrumentation are analyzed. Applications to industrial dust measurements, source testing, ambient monitoring, and particle size analysis are the major areas of practical utilization of this technique, and its inherent capability for automated and unattended operation provides compatibility with process control synchronization and alarm, telemetry, and incorporation into pollution monitoring network sensing stations. (orig.) [de

  12. Field measurement and interpretation of beta doses and dose rates

    International Nuclear Information System (INIS)

    Selby, J.M.; Swinth, K.L.; Hooker, C.D.; Kenoyer, J.L.

    1983-01-01

    A large number of portable survey instruments employing G.M., ionization chamber, and scintillation detectors used for gamma measurements are also used for monitoring in beta fields by using removable shields to separate the beta and gamma components of the radiation field. The difference does not correspond to an absorbed dose rate for the beta field due to a variety of factors. Among these factors are the dependence on beta energy, source-detector geometries, mixed fields and variable ambient conditions. Attempting to use such measurements directly can lead to errors as high as a factor of 100. Appropriate calibrations and correction factors can be used to reduce the errors in beta measurements to a tolerable level

  13. Beta decay to the second 2+ excited state of 122Te

    International Nuclear Information System (INIS)

    Hayashi, Takeo; Yamada, Shigeru

    1976-01-01

    The first-forbidden beta transition in Sb-122 was studied by the angular correlation experiment and the beta-spectra. The special precautions were paid for counting the beta particles having energy lower than 750 keV in the beta-gamma angular correlation measurement. The sources of Sb-122 were obtained by irradiating enriched Sb-121 in the Kyoto University reactor. The reduced beta coefficient R(E) was obtained from the angular correlation function. The beta spectrum measurement was performed with a sector type double focusing beta-ray spectrometer. The R(E) values for the beta transitions were analyzed by using the simplex method as used by Manthuruthil and Poirier to compare the angular correlation data with the exact formula given by Morita and Morita. Sets of the nuclear matrix parameters thus obtained show that the condition for the cancellation effect is satisfied in the beta transition. (Kato, T.)

  14. Interactions between two beta-sheets. Energetics of beta/beta packing in proteins.

    Science.gov (United States)

    Chou, K C; Némethy, G; Rumsey, S; Tuttle, R W; Scheraga, H A

    1986-04-20

    The analysis of the interactions between regularly folded segments of the polypeptide chain contributes to an understanding of the energetics of protein folding. Conformational energy-minimization calculations have been carried out to determine the favorable ways of packing two right-twisted beta-sheets. The packing of two five-stranded beta-sheets was investigated, with the strands having the composition CH3CO-(L-Ile)6-NHCH3 in one beta-sheet and CH3CO-(L-Val)6-NHCH3 in the other. Two distinct classes of low-energy packing arrangements were found. In the class with lowest energies, the strands of the two beta-sheets are aligned nearly parallel (or antiparallel) with each other, with a preference for a negative orientation angle, because this arrangement corresponds to the best complementary packing of the two twisted saddle-shaped beta-sheets. In the second class, with higher interaction energies, the strands of the two beta-sheets are oriented nearly perpendicular to each other. While the surfaces of the two beta-sheets are not complementary in this arrangement, there is good packing between the corner of one beta-sheet and the interior part of the surface of the other, resulting in a favorable energy of packing. Both classes correspond to frequently observed orientations of beta-sheets in proteins. In proteins, the second class of packing is usually observed when the two beta-sheets are covalently linked, i.e. when a polypeptide strand passes from one beta-sheet to the other, but we have shown here that a large contribution to the stabilization of this packing arrangement arises from noncovalent interactions.

  15. Interaction with beta-arrestin determines the difference in internalization behavor between beta1- and beta2-adrenergic receptors.

    Science.gov (United States)

    Shiina, T; Kawasaki, A; Nagao, T; Kurose, H

    2000-09-15

    The beta(1)-adrenergic receptor (beta(1)AR) shows the resistance to agonist-induced internalization. As beta-arrestin is important for internalization, we examine the interaction of beta-arrestin with beta(1)AR with three different methods: intracellular trafficking of beta-arrestin, binding of in vitro translated beta-arrestin to intracellular domains of beta(1)- and beta(2)ARs, and inhibition of betaAR-stimulated adenylyl cyclase activities by beta-arrestin. The green fluorescent protein-tagged beta-arrestin 2 translocates to and stays at the plasma membrane by beta(2)AR stimulation. Although green fluorescent protein-tagged beta-arrestin 2 also translocates to the plasma membrane, it returns to the cytoplasm 10-30 min after beta(1)AR stimulation. The binding of in vitro translated beta-arrestin 1 and beta-arrestin 2 to the third intracellular loop and the carboxyl tail of beta(1)AR is lower than that of beta(2)AR. The fusion protein of beta-arrestin 1 with glutathione S-transferase inhibits the beta(1)- and beta(2)AR-stimulated adenylyl cyclase activities, although inhibition of the beta(1)AR-stimulated activity requires a higher concentration of the fusion protein than that of the beta(2)AR-stimulated activity. These results suggest that weak interaction of beta(1)AR with beta-arrestins explains the resistance to agonist-induced internalization. This is further supported by the finding that beta-arrestin can induce internalization of beta(1)AR when beta-arrestin 1 does not dissociate from beta(1)AR by fusing to the carboxyl tail of beta(1)AR.

  16. A practical method for in-situ thickness determination using energy distribution of beta particles

    International Nuclear Information System (INIS)

    Yalcin, S.; Gurler, O.; Gundogdu, O.; Bradley, D.A.

    2012-01-01

    This paper discusses a method to determine the thickness of an absorber using the energy distribution of beta particles. An empirical relationship was obtained between the absorber thickness and the energy distribution of beta particles transmitted through. The thickness of a polyethylene radioactive source cover was determined by exploiting this relationship, which has largely been left unexploited allowing us to determine the in-situ cover thickness of beta sources in a fast, cheap and non-destructive way. - Highlights: ► A practical and in-situ unknown cover thickness determination ► Cheap and readily available compared to other techniques. ► Beta energy spectrum.

  17. A practical method for in-situ thickness determination using energy distribution of beta particles

    Energy Technology Data Exchange (ETDEWEB)

    Yalcin, S., E-mail: syalcin@kastamonu.edu.tr [Kastamonu University, Education Faculty, 37200 Kastamonu (Turkey); Gurler, O. [Physics Department, Faculty of Arts and Sciences, Uludag University, Gorukle Campus, 16059 Bursa (Turkey); Gundogdu, O. [Kocaeli University, Umuttepe Campus, 41380 Kocaeli (Turkey); Bradley, D.A. [CNRP, Department of Physics, Faculty of Engineering and Physical Sciences, University of Surrey, Guildford GU2 7XH (United Kingdom)

    2012-01-15

    This paper discusses a method to determine the thickness of an absorber using the energy distribution of beta particles. An empirical relationship was obtained between the absorber thickness and the energy distribution of beta particles transmitted through. The thickness of a polyethylene radioactive source cover was determined by exploiting this relationship, which has largely been left unexploited allowing us to determine the in-situ cover thickness of beta sources in a fast, cheap and non-destructive way. - Highlights: Black-Right-Pointing-Pointer A practical and in-situ unknown cover thickness determination Black-Right-Pointing-Pointer Cheap and readily available compared to other techniques. Black-Right-Pointing-Pointer Beta energy spectrum.

  18. Beta-gradient isochron dating of thin tooth enamel layers using ESR

    International Nuclear Information System (INIS)

    Marsh, R.E.Rebeccah E.; Rink, W.J.W. Jack

    2000-01-01

    The theoretical and experimental basis for the development of a new dating technique using beta-gradient isochrons and ESR is presented. For uranium-free portions of enamel adjacent to sediment, we can determine a beta-dose gradient due to sources in the nearest 2 mm layer of the sediment. If the equivalent dose to successive layers of enamel is plotted against the beta dose rate to each layer, an estimate of the age (equal to the slope of the line) that depends only on the environmental beta dose rate can be determined. Experimental methods and results for four teeth are discussed. The significance of this approach lies in its ability to isolate an age estimate that is independent of the uranium uptake model, since only portions of the enamel which are far away enough from internal sources of uranium, such as dentine, are used. In addition, this technique provides a time-averaged estimate of the actual gamma plus cosmic dose rate provided that a reasonable estimate of the average moisture content is used to calculate the environmental beta dose rate

  19. Application of gel dosimetry - A preliminary study on verification of uniformity of activity and length of source used in Beta-Cath system

    International Nuclear Information System (INIS)

    Subramaniam, S.; Rabi Raja Singh, I.; Visalatchi, S.; Paul Ravindran, B.

    2002-01-01

    Recently the intraluminal irradiation of coronary arteries following balloon angioplasty is found to reduce proliferation of smooth muscle cells and restenosis. Among the isotopes used for the intracoronary irradiation, 90 Sr/Y appears to be ideal (H I Almos et al, 1996). In 1984 Gore et al proposed that radiation induced changes in the well-established Fricke solution could be probed with Nuclear Magnetic Resonance (NMR) relaxation measurements rather than using conventional spectrophotometry measurements. This was a major step in the development of gel dosimetry and since then gel dosimetry has been one of the major advances in the dosimetry of complex radiation fields has been in the area of gel dosimetry. In this preliminary work on gel dosimetry we present the verification of uniformity of activity along the length of the source train and verification of the length of the source used in the Beta-Cath system used for intracoronary brachytherapy with ferrous gel dosimeter. The Beta-Cath system obtained from Novoste, Norcross, GA was used in this study. It consists of a source train of 16 90 Sr/Y sources each of length 2.5mm. The total length of the source train is 40mm. For preparation of the Ferrous-Gelatin Gel, the recipe provided by the London Regional Cancer Center, London Ontario, Canada was used. Stock solutions of 50mM H 2 SO 4 , 0.3 mM ferrous ammonium sulphate, 0.05mM Xylenol orange was first prepared. The gel was prepared by mixing 4% gelatin with distilled water while stirring in a water bath at 40-42 deg. C. Acid solution, Ferrous ammonium sulphate solution and Xylenol orange were added and stirred in the water bath for about an hour to allow aeration. The mixture was poured in to three 20ml syringes to form the gel and stored in the refrigerator at 5 deg. C. For irradiation with Beta-Cath, the gel was prepared in three cylindrical 20ml syringes. A nylon tube having the same dimension as that of the delivery catheter used in intra-coronary was placed

  20. Eukaryotic beta-alanine synthases are functionally related but have a high degree of structural diversity

    DEFF Research Database (Denmark)

    Gojkovic, Zoran; Sandrini, Michael; Piskur, Jure

    2001-01-01

    no pyrimidine catabolic pathway, it enabled growth on N-carbamyl- beta -alanine as the sole nitrogen source. The D. discoideum and D. melanogaster PYD3 gene products are similar to mammalian beta -alanine synthases. In contrast, the S. kluyveri protein is quite different from these and more similar to bacterial......beta -Alanine synthase (EC 3.5.1.6), which catalyzes the final step of pyrimidine catabolism, has only been characterized in mammals. A Saccharomyces kluyveri pyd3 mutant that is unable to grow on N-carbamy-beta -alanine as the sole nitrogen source and exhibits diminished beta -alanine synthase...... N- carbamyl amidohydrolases. All three beta -alanine synthases are to some degree related to various aspartate transcarbamylases, which catalyze the second step of the de novo pyrimidine biosynthetic pathway. PYD3 expression in yeast seems to be inducible by dihydrouracil and N...

  1. Properties of an extrapolation chamber for beta radiation dosimetry

    International Nuclear Information System (INIS)

    Caldas, L.V.E.

    The properties of a commercial extrapolation chamber were studied, and the possibility is shown of its use in beta radiation dosimetry. The chamber calibration factors were determined for several sources ( 90 Sr, 90 Y- 204 Tl and 147 Pm) making known the dependence of its response on the energy of the incident radiation. Extrapolation curves allow to obtain independence on energy for each source. One of such curves, shown for the 90 Sr- 90 Y source at 50 cm from the detector, is obtained through the variation of the chamber window thickness and the extrapolation to the null distance (determined graphically). Different curves shown also: 1) the dependence of the calibration factor on the average energy of beta radiation; 2) the variation of ionization current with the distance between the chamber and the sources; 3) the effect of the collecting electrode area on the value of calibration factors for the different sources. (I.C.R.) [pt

  2. Measurement of the 2{nu}{beta}{beta} decay of {sup 100}Mo to the excited 0{sub 1}{sup +} state in the NEMO3 experiment

    Energy Technology Data Exchange (ETDEWEB)

    Vala, L

    2003-09-01

    The NEMO3 detector was designed for the study of double beta decay and in particular to search for the neutrinoless double beta decay process (0{nu}{beta}{beta}). The intended sensitivity in terms of a half-life limit for the 0{nu}{beta}{beta} decay is of the order of 10{sup 25} y which corresponds to an effective neutrino mass m{sub {nu}} on the level of (0.3 - 0.1) eV. The 0{nu}{beta}{beta} process is today the most promising test of the Majorana nature of the neutrino. The detector was constructed in the Modane Underground Laboratory (LSM) in France by an international collaboration including France, Russia, the Czech Republic, the USA, the UK, Finland, and Japan. The experiment has been taking data since May 2002. The quantity of {sup 100}Mo in the detector (7 kg) allows an efficient measurement of the two-neutrino double beta decay (2{nu}{beta}{beta}) of {sup 100}Mo to the excited 0{sub 1}{sup +} state (eeN{gamma} channel). Monte-Carlo simulations of the effect and of all the relative sources of background have been produced in order to define a set of appropriate selection criteria. Both Monte-Carlo simulations and special runs with sources of {sup 208}Tl and {sup 214}Bi showed that the only significant background in the eeN{gamma} channel comes from radon that penetrated inside the wire chamber of NEMO3. The experimental data acquired from May 2002 to May 2003 have been analysed in order to determine the signal from the 2{nu}{beta}{beta} decay of {sup 100}Mo to the excited 0{sub 1}{sup +} state and the corresponding background level. The physical result, which was obtained at the level of four standard deviations, is given in the form of an interval of half-life values at 95% confidence level: [5.84*10{sup 20}, 2.26*10{sup 21}] y for method A and [5.83*10{sup 20}, 1.71*10{sup 21}] y for method B. (author)

  3. Beta adrenergic receptors in human cavernous tissue

    Energy Technology Data Exchange (ETDEWEB)

    Dhabuwala, C.B.; Ramakrishna, C.V.; Anderson, G.F.

    1985-04-01

    Beta adrenergic receptor binding was performed with /sup 125/I iodocyanopindolol on human cavernous tissue membrane fractions from normal tissue and transsexual procedures obtained postoperatively, as well as from postmortem sources. Isotherm binding studies on normal fresh tissues indicated that the receptor density was 9.1 fmoles/mg. with a KD of 23 pM. Tissue stored at room temperature for 4 to 6 hours, then at 4C in saline solution for 19 to 20 hours before freezing showed no significant changes in receptor density or affinity, and provided evidence for the stability of postmortem tissue obtained within the same time period. Beta receptor density of 2 cavernous preparations from transsexual procedures was not significantly different from normal control tissues, and showed that high concentrations of estrogen received by these patients had no effect on beta adrenergic receptor density. Displacement of /sup 125/iodocyanopindolol by 5 beta adrenergic agents demonstrated that 1-propranolol had the greatest affinity followed by ICI 118,551, zinterol, metoprolol and practolol. When the results of these displacement studies were subjected to Scatfit, non- linear regression line analysis, a single binding site was described. Based on the relative potency of the selective beta adrenergic agents it appears that these receptors were of the beta 2 subtype.

  4. {beta} {gamma} porch detector; Detecteur portique {beta} {gamma}

    Energy Technology Data Exchange (ETDEWEB)

    Roulet, R [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1963-07-01

    This device is to be placed at the outside of reactors, hot laboratories and others where radioactive products are treated; it is intended to give the alarm when someone, passing through the porch is greatly contaminated, or carries, without his knowing, a radioactive substance. Being to be used in places where there might be an important ground noise, this device is provided with an automatic offset of this noise; an adjusting system of sensitivity allows to obtain a 15 {mu}Ci in {gamma} and 10 {mu}Ci in {beta} radioactive source, passing through the porch at the normal speed at which man is walking. A battery, set in buffer, allows working of the device, even when current is off. (author) [French] Cet appareil est destine a etre place a la sortie des reacteurs, laboratoires chauds ou autres laboratoires travaillant sur des produits radioactifs; son but est de donner une alarme lorsque quelqu'un, passant sous le portique, presente une forte contamination, ou surtout transporte par inadvertance un corps radioactif. Cet appareil devant etre utilise dans les lieux ou peut regner un bruit de fond important, possede une compensation automatique de ce bruit de fond; un reglage de la sensibilite permet d'obtenir au mieux un declenchement pour une source. de 15 {mu}Ci en {gamma} et 10 {mu}Ci en {beta} passant sous le portique a la vitesse normale d'un homme qui marche. Une batterie montee en tampon permet a l'appareil de fonctionner meme en cas de coupure de courant. (auteur)

  5. Electret dosemeter for beta radiation

    International Nuclear Information System (INIS)

    Campos, L.L.; Caldas, L.V.E.; Mascarenhas, S.

    The response characteristics of an electret dosemeter for beta radiation are studied. Experiments were performed using different geometries and walls, and it was verified for which geometry the dosemeter sensitivity is greater. Sources of 90 Sr - 90 Y, 204 Tl and 85 Kr were used in the experiments. (I.C.R.) [pt

  6. Sequence swapping does not result in conformation swapping for the beta4/beta5 and beta8/beta9 beta-hairpin turns in human acidic fibroblast growth factor.

    Science.gov (United States)

    Kim, Jaewon; Lee, Jihun; Brych, Stephen R; Logan, Timothy M; Blaber, Michael

    2005-02-01

    The beta-turn is the most common type of nonrepetitive structure in globular proteins, comprising ~25% of all residues; however, a detailed understanding of effects of specific residues upon beta-turn stability and conformation is lacking. Human acidic fibroblast growth factor (FGF-1) is a member of the beta-trefoil superfold and contains a total of five beta-hairpin structures (antiparallel beta-sheets connected by a reverse turn). beta-Turns related by the characteristic threefold structural symmetry of this superfold exhibit different primary structures, and in some cases, different secondary structures. As such, they represent a useful system with which to study the role that turn sequences play in determining structure, stability, and folding of the protein. Two turns related by the threefold structural symmetry, the beta4/beta5 and beta8/beta9 turns, were subjected to both sequence-swapping and poly-glycine substitution mutations, and the effects upon stability, folding, and structure were investigated. In the wild-type protein these turns are of identical length, but exhibit different conformations. These conformations were observed to be retained during sequence-swapping and glycine substitution mutagenesis. The results indicate that the beta-turn structure at these positions is not determined by the turn sequence. Structural analysis suggests that residues flanking the turn are a primary structural determinant of the conformation within the turn.

  7. Study and industrial applications of the external slowing-down {beta}{sup -} radiation of the yttrium - 90; Etude et applications industrielles du rayonnement de freinage externe des {beta}{sup -} de l'yttrium - 90

    Energy Technology Data Exchange (ETDEWEB)

    Leveque, P; Martinelli, P; Chauvin, R [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1955-07-01

    Inelastic scattering of the {beta}{sup -} particles on the nucleus gives place to the emission of a X-ray Bremsstrahlung radiation. In view of possible industrial applications, we studied the slowing-down radiation of {sup 90}(Sr + Y) sources in various materials. This pure {beta}{sup -} emitter of long period is in the fission products of uranium. Among of the industrial applications, these sources of weak X-rays energy can be used for the radiography of thin pieces, for measuring the thickness, or for the analysis by fluorescence. (M.B.) [French] La diffusion inelastique des particules {beta}{sup -} sur les noyaux donne lieu a l'emission d'un rayonnement X de freinage. En vue de possibles applications industrielles, nous avons etudie le rayonnement de freinage des sources {sup 90}(Sr + Y) dans divers materiaux. Cet emetteur {beta}{sup -} pur a longue periode se trouve dans les produits de fission de l'uranium. Parmi les applications industrielles a l'etude, ces sources de rayons X de faible energie peuvent etre utilisees pour la radiographie de pieces minces, la mesure d'epaisseurs, ou encore pour l'analyse par fluorescence. (M.B.)

  8. Dosimetry studies with 32P source and correlation of skin and eye lens doses

    International Nuclear Information System (INIS)

    Kumar, Munish; Gaonkar, U.P.; Koul, D.K.; Datta, D.; Saxena, S.K.; Kumar, Yogendra; Dash, A.

    2018-01-01

    Beta particles are one of the major contributors toward skin and eye lens doses at facilities handling beta sources. These sources find applications in industry, pharmaceuticals as well as in brachytherapy applications. The beta particles having maximum (E max ) energy > 0.07 MeV are capable of delivering skin dose whereas beta particles having maximum (E max ) energy > 0.7 MeV may also contribute towards dose to eye lens. Studies are performed using 32 P beta source as its maximum beta energy (E max ) is such that for sources having (E max ) of 1.71 MeV or beyond, there can be substantial contribution towards dose to eye lens even the dose limit recommended for skin is followed

  9. High energy beta rays and vectors of Bilharzia and Fasciola

    International Nuclear Information System (INIS)

    Fletcher, J.J.; Akpa, T.C.; Dim, L.A.; Ogunsusi, R.

    1988-01-01

    Preliminary investigations of the effects of high energy beta rays on Lymnea natalensis, the snail vector of Schistosoma haematobium have been conducted. Results show that in both stream and tap water, about 70% of the snails die when irradiated for up to 18 hours using a 15m Ci Sr-90 beta source. The rest of the snails die without further irradiation in 24 hours. It may then be possible to control the vectors of Bilharzia and Fasciola by using both the direct and indirect effects of high energy betas. (author)

  10. High energy beta rays and vectors of Bilharzia and Fasciola

    Energy Technology Data Exchange (ETDEWEB)

    Fletcher, J.J.; Akpa, T.C.; Dim, L.A.; Ogunsusi, R.

    1988-01-01

    Preliminary investigations of the effects of high energy beta rays on Lymnea natalensis, the snail vector of Schistosoma haematobium have been conducted. Results show that in both stream and tap water, about 70% of the snails die when irradiated for up to 18 hours using a 15m Ci Sr-90 beta source. The rest of the snails die without further irradiation in 24 hours. It may then be possible to control the vectors of Bilharzia and Fasciola by using both the direct and indirect effects of high energy betas.

  11. Monte Carlo dose calculations of beta-emitting sources for intravascular brachytherapy: a comparison between EGS4, EGSnrc, and MCNP.

    Science.gov (United States)

    Wang, R; Li, X A

    2001-02-01

    The dose parameters for the beta-particle emitting 90Sr/90Y source for intravascular brachytherapy (IVBT) have been calculated by different investigators. At a distant distance from the source, noticeable differences are seen in these parameters calculated using different Monte Carlo codes. The purpose of this work is to quantify as well as to understand these differences. We have compared a series of calculations using an EGS4, an EGSnrc, and the MCNP Monte Carlo codes. Data calculated and compared include the depth dose curve for a broad parallel beam of electrons, and radial dose distributions for point electron sources (monoenergetic or polyenergetic) and for a real 90Sr/90Y source. For the 90Sr/90Y source, the doses at the reference position (2 mm radial distance) calculated by the three code agree within 2%. However, the differences between the dose calculated by the three codes can be over 20% in the radial distance range interested in IVBT. The difference increases with radial distance from source, and reaches 30% at the tail of dose curve. These differences may be partially attributed to the different multiple scattering theories and Monte Carlo models for electron transport adopted in these three codes. Doses calculated by the EGSnrc code are more accurate than those by the EGS4. The two calculations agree within 5% for radial distance <6 mm.

  12. Expression of transforming growth factor beta (TGF beta) receptors and expression of TGF beta 1, TGF beta 2 and TGF beta 3 in human small cell lung cancer cell lines

    DEFF Research Database (Denmark)

    Damstrup, L; Rygaard, K; Spang-Thomsen, M

    1993-01-01

    A panel of 21 small cell lung cancer cell (SCLC) lines were examined for the presence of Transforming growth factor beta receptors (TGF beta-r) and the expression of TGF beta mRNAs. By the radioreceptor assay we found high affinity receptors to be expressed in six cell lines. scatchard analysis......(r) = 65,000 and 90,000 and the betaglycan (type III) with M(r) = 280,000. Northern blotting showed expression of TGF beta 1 mRNA in ten, TGF beta 2 mRNA in two and TGF beta 3 mRNA in seven cell lines. Our results provide, for the first time, evidence that a large proportion of a broad panel of SCLC cell...... lines express TGF beta-receptors and also produce TGF beta mRNAs....

  13. Results of the BiPo-1 prototype for radiopurity measurements for the SuperNEMO double beta decay source foils

    Energy Technology Data Exchange (ETDEWEB)

    Argyriades, J. [LAL, Universite Paris-Sud, CNRS/IN2P3, F-91405 Orsay (France); Arnold, R. [IPHC, Universite de Strasbourg, CNRS/IN2P3, F-67037 Strasbourg (France); Augier, C. [LAL, Universite Paris-Sud, CNRS/IN2P3, F-91405 Orsay (France); Baker, J. [INL, Idaho Falls, ID 83415 (United States); Barabash, A.S. [Institute of Theoretical and Experimental Physics, 117259 Moscow (Russian Federation); Basharina-Freshville, A. [University College London, WC1E 6BT London (United Kingdom); Bongrand, M.; Bourgeois, C.; Breton, D.; Briere, M.; Broudin-Bay, G. [LAL, Universite Paris-Sud, CNRS/IN2P3, F-91405 Orsay (France); Brudanin, V.B. [Joint Institute for Neear Research, 141980 Dubna (Russian Federation); Caffrey, A.J. [INL, Idaho Falls, ID 83415 (United States); Carcel, S. [Instituto de Fisica Corpuscular, CSIC, Universidad de Valencia, Valencia (Spain); Cebrian, S. [Instituto de Fisica Nuclear y Altas Energias, Universidad de Zaragoza, Zaragoza (Spain); Chapon, A. [LPC Caen, ENSICAEN, Universite de Caen, CNRS/IN2P3, F-14032 Caen (France); Chauveau, E. [CNRS/IN2P3, Centre d' Etudes Nucleaires de Bordeaux Gradignan, UMR 5797, F-33175 Gradignan (France); Universite de Bordeaux, Centre d' Etudes Nucleaires de Bordeaux Gradignan, UMR 5797, F-33175 Gradignan (France); Dafni, Th. [Instituto de Fisica Nuclear y Altas Energias, Universidad de Zaragoza, Zaragoza (Spain); Diaz, J. [Instituto de Fisica Corpuscular, CSIC, Universidad de Valencia, Valencia (Spain); Durand, D. [LPC Caen, ENSICAEN, Universite de Caen, CNRS/IN2P3, F-14032 Caen (France)

    2010-10-01

    The development of BiPo detectors is dedicated to the measurement of extremely high radiopurity in {sup 208}Tl and {sup 214}Bi for the SuperNEMO double beta decay source foils. A modular prototype, called BiPo-1, with 0.8 m{sup 2} of sensitive surface area, has been running in the Modane Underground Laboratory since February, 2008. The goal of BiPo-1 is to measure the different components of the background and in particular the surface radiopurity of the plastic scintillators that make up the detector. The first phase of data collection has been dedicated to the measurement of the radiopurity in {sup 208}Tl. After more than one year of background measurement, a surface activity of the scintillators of A({sup 208}Tl)=1.5{mu}Bq/m{sup 2} is reported here. Given this level of background, a larger BiPo detector having 12 m{sup 2} of active surface area, is able to qualify the radiopurity of the SuperNEMO selenium double beta decay foils with the required sensitivity of A({sup 208}Tl)<2{mu}Bq/kg (90% C.L.) with a six month measurement.

  14. Beta-energy averaging and beta spectra

    International Nuclear Information System (INIS)

    Stamatelatos, M.G.; England, T.R.

    1976-07-01

    A simple yet highly accurate method for approximately calculating spectrum-averaged beta energies and beta spectra for radioactive nuclei is presented. This method should prove useful for users who wish to obtain accurate answers without complicated calculations of Fermi functions, complex gamma functions, and time-consuming numerical integrations as required by the more exact theoretical expressions. Therefore, this method should be a good time-saving alternative for investigators who need to make calculations involving large numbers of nuclei (e.g., fission products) as well as for occasional users interested in restricted number of nuclides. The average beta-energy values calculated by this method differ from those calculated by ''exact'' methods by no more than 1 percent for nuclides with atomic numbers in the 20 to 100 range and which emit betas of energies up to approximately 8 MeV. These include all fission products and the actinides. The beta-energy spectra calculated by the present method are also of the same quality

  15. Speculative Betas

    OpenAIRE

    Harrison Hong; David Sraer

    2012-01-01

    We provide a model for why high beta assets are more prone to speculative overpricing than low beta ones. When investors disagree about the common factor of cash-flows, high beta assets are more sensitive to this macro-disagreement and experience a greater divergence-of-opinion about their payoffs. Short-sales constraints for some investors such as retail mutual funds result in high beta assets being over-priced. When aggregate disagreement is low, expected return increases with beta due to r...

  16. Electrets for beta radiation detection

    International Nuclear Information System (INIS)

    Campos, L.L.; Caldas, L.V.E.; Mascarenhas, S.

    1983-01-01

    Electret dosimetry has been reviewed by Gross. A cylindrical electret ionization-chamber type dosimeter has been studied for X and gamma rays and neutrons. The principle of the dosimeter is electret charge compensation due to ionization in the chamber volume. Electret ionization chambers can be designed with one or more electrets and in various shapes. This study is concerned with a simple system, similar to a cylindrical ionization chamber (sensitive volume: 3,5 cm 3 ) using teflon electrets. Aluminum and lucite were used as wall-materials. Other experiences were performed using chambers without wall, i.e., without defined sensitive volume. The teflon electrets were obtained by Corona discharge in the gas surrounding them. The measurement of the electret charge was made by induction using a co-axial insulated metal chamber connected to an electrometer Keithley 610C. By measuring the charge before and after irradiation it is possible to obtain a calibration curve: charge (Q) versus absorbed dose (D) for the dosimeter. The irradiation setup used was the Beta Secondary Standard System of IPEN calibration laboratory with four beta sources: 90 Sr 90 Y (74 and 1850 MBq), 204 Tl (18,5 MBq) and 147 Pm (518 MBq). In some cases a 85 Kr source was also used. The electrets were tested in different radiation field geometries: electret axis parallel and perpendicular to the field. In conclusion, depending on the wall material and radiation field geometry, the teflon electret detector can be used for different dose interval determinations, using beta radiation

  17. Analysis of radionuclide mixtures by {alpha}-{gamma} and {beta}-{gamma} coincidences using a simple device; Analyse de melanges de radionucleides par un dispositif simple de coincidences {alpha}-{gamma} et {beta}-{gamma}

    Energy Technology Data Exchange (ETDEWEB)

    Pottier, R; Berger, R [Commissariat a l' Energie Atomique, Centre d' Etudes Nucleaires de Fontenay-aux-Roses, 92 (France)

    1966-06-01

    A procedure is described for the qualitative and quantitative spectrographic analysis of radioactive sources containing two alpha-gamma emitters having the same alpha energy or two beta-gamma emitters having the same gamma energy. The main apparatus is a multichannel pulse-height analyzer including a coincidence circuit. The principle of the method, the synoptic scheme, the electronic device, the type of sources, and the precautions to be taken or the corrections to take into account are reported. The results obtained in solving the three following problems are discussed as examples of applications of the method: analysis of {sup 241}Am in alpha-gamma sources containing {sup 238}Pu; analysis of {sup 237}Np in beta-gamma sources containing {sup 239}Pu; and analysis of {sup 106}Ru-{sup 106}Rh in beta-gamma sources containing {sup 95}Zr-{sup 95}Nb. (authors) [French] Dans ce. rapport, on presente une methode d'analyse spectrographique qualitative et quantitative de sources radioactives contenant deux emetteurs alpha-gamma de meme energie alpha et deux emetteurs beta-gamma de meme energie gamma. L'organe principal est un analyseur d'amplitude a 400 canaux comprenant un circuit de coincidence. On decrit le principe de la methode, le schema synoptique, l'appareillage, le type des sources, les precautions a prendre ou les corrections a faire. On discute les resultats obtenus dans la solution des trois problemes suivants traites a titre d'application de la methode: 1. analyse d'americium 241 en presence de plutonium 238; 2. analyse de neptunium 237 en presence de plutonium 239; 3. analyse de ruthenium 106-rhodium 106 en presence de zirconium 95-niobium 95. (auteurs)

  18. Labelling of. beta. -endorphin (. beta. -END) and. beta. -lipotropin (. beta. -LPH) by /sup 125/I

    Energy Technology Data Exchange (ETDEWEB)

    Deby-Dupont, G.; Joris, J.; Franchimont, P. (Universite de Liege (Belgique)); Reuter, A.M.; Vrindts-Gevaert, Y. (Institut des Radioelements, Fleurus (Belgique))

    1983-01-01

    5 ..mu..g of human ..beta..-endorphin were labelled with 2 mCi /sup 125/I by the chloramine T technique. After two gel filtrations on Sephadex G-15 and on Sephadex G-50 in phosphate buffer with EDTA, Trasylol and mercapto-ethanol, a pure tracer was obtained with a specific activity about 150 ..mu..Ci/..mu..g.Kept at + 4/sup 0/C, the tracer remained utilizable for 30 days without loss of immunoreactivity. The labelling with lactoperoxydase and the use of another gel filtration method (filtration on Aca 202) gave a /sup 125/I ..beta..-END tracer with the same immunoreactivity. The binding of this tracer to the antibody of an anti-..beta..-END antiserum diluted at 1/8000 was 32% with a non specific binding of 2%. 5 ..mu..g of human ..beta..-lipotropin were labelled with 0.5 mCi /sup 125/I by the lactoperoxydase method. After two gel filtrations on Sephadex G-25 and on Sephadex G-75 in phosphate buffer with EDTA, Trasylol and mercapto-ethanol, a pure tracer with a specific activity of 140 ..mu..Ci/..mu..g was obtained. It remained utilizable for 30 days when kept at + 4/sup 0/C. Gel filtration on Aca 202 did not give good purification, while gel filtration on Aca 54 was good but slower than on Sephadex G-75. The binding to antibody in absence of unlabelled ..beta..-LPH was 32% for an anti-..beta..-LPH antiserum diluted at 1/4000. The non specific binding was 2.5%.

  19. Study of the background of the neutrinoless double {beta} decay with the detector NEMO 2: contribution arising from the radon diffusion and internal pollution of the source {sup 214}Bi have been estimated; Etude du bruit de fond de la double-desintegration {beta} sans emission de neutrino dans le detecteur NEMO 2: contribution du radon ambiant et mesure de la pollution interne de la source en {sup 214}Bi

    Energy Technology Data Exchange (ETDEWEB)

    Mauger, F.

    1995-02-01

    The NEMO experiment is designed to understand the nature of the neutrino by studying the double beta decay of Mo-100 which is related to the Majorana neutrino effective mass. In this kind of experiment a good understanding of the different sources of background is crucial as only few events are expected per year at the required level of sensitivity. In this thesis we present the main theoretical and experimental aspects of the measurement of the neutrinoless double beta decay of Mo-100 with the prototype detector NEMO2. The goal of this study is to obtain a realistic interpretation of the few events detected at high energy in the two-electron channel as a background to neutrinoless double beta decay. In particular, the contribution arising from Bi-214 has been investigated. These events have been selected and analysed by means of the beta-alpha decays of Bi-214 into Pb-210. The events are characterized by a delayed track in the wire chamber and the corresponding signal is rather clean. The study has demonstrated the diffusion of Rn-222 into the detector and its contribution to Bi-214 pollution has been estimated. A measurement of the Bi-214 internal contamination of the source has been made as well as an estimation of the Bi-214 deposit due to Rn-222. As a result of this study it appears that, under the conditions of the NEMO2 experiment, the Bi and Rn contributions are of the same order of magnitude as the background induced at high energy by two-neutrino double beta decay. In conclusion, the backgrounds of the neutrinoless double beta decay of Mo-100 are well understood in the NEMO2 experiment leading to an extrapolation for the NEMO3 experiment. (authors).

  20. Theoretical study and construction of a multichannel {beta} spectrometer with uniform magnetic field; Etude et realisation d'un spectrometre {beta} multivoies a champ magnetique uniforme

    Energy Technology Data Exchange (ETDEWEB)

    Schussler, F [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1965-09-01

    After a brief survey of the interest of a multichannel beta spectrometer for studying decay schemes of short lived nuclides (30 seconds minimum, the theoretically well known characteristics of uniform magnetic field analyser (image of a large source, transmission and resolution) are briefly remembered. In the second part, the apparatus built as a result of these calculations is described. This apparatus allows the determination of beta spectra by simultaneous determination of the beta spectra in coincidence with four gamma rays predetermined in the gamma spectrum of the studied nuclide. Finally, in the last part, the experimental characteristics of the spectrometer (calibration in energy and transmission) and the first measurement of beta spectra ({sup 155}Sm) and of coincidences ({sup 24}Na), are given. (author) [French] Apres avoir brievement souligne l'interet pratique que presente un spectrometre multivoies pour l'etude des schemas de desintegration des corps radioactifs de courtes periodes (30 secondes au maximum), l'auteur effectue un rappel des caracteristiques theoriques bien connues d'un analyseur magnetique a champ uniforme (image d'une source etendue) calcul de la transmission et du pouvoir de resolution. Une deuxieme partie est consacree a la description de l'appareil realise d'apres ces calculs. Cet appareil permet le releve des spectres beta par detection, simultanee de dix groupes d'electrons d'energies differentes; il permet egalement le releve simultane des spectres beta en coincidence avec quatre rayonnements gammas preselectionnes a l'avance dans le spectre gamma du corps etudie. Dans une derniere partie enfin, sont donnees les caracteristiques experimentales du spectrometre (etalonnage en energie et en transmission) ainsi que les premiers resultats des etudes de spectre beta ({sup 155}Sm) et de coincidence ({sup 24}Na). (auteur)

  1. Development of 63Ni sources for defence related applications

    International Nuclear Information System (INIS)

    Udhayakumar, J.; Pardeshi, G.S.; Gandhi, Shyamala S.; Dash, A.; Venkatesh, Meera

    2004-01-01

    63 Ni is seen as a good substitute for the conventional sources of ionization used in electron capture detectors in Gas Chromatography applications. It has advantages such as source stability, reasonably long shelf life due to its long half-life and viable for safe and easy handling due to low energy beta emission. At the special request from the Defence Establishments in India for supply of 63 Ni beta source on special dimension of a curved inner copper ring area, the new electro-deposition cell was designed and used for routine preparation and supply of such sources. The paper describes the procedure for fabrication of 63 Ni beta sources by electro-deposition method. Activity up to ∼370 MBq (∼10 mCi) was electrodeposited exclusively on inner curved area of ∼4 sq.cm. Copper annular ring, using Boric acid electrolyte bath solution at a temperature range of 50 deg - 60 deg C with a current density of ∼ 6 ma/sq.cm. For this purpose, a new electro depositing cell was specially designed and used. The paper discusses the details regarding source requirement, source preparation parameters, film thickness and its impact on beta output, source quality control aspects and other applications of the sources. The paper also highlights the demand and supply scenario of such electrodeposited sources, in terms of commercial supply sale value, as an import substitute. (author)

  2. Effect of Sertraline on Current-Source Distribution of the High Beta Frequency Band: Analysis of Electroencephalography under Audiovisual Erotic Stimuli in Healthy, Right-Handed Males.

    Science.gov (United States)

    Lee, Seung Hyun; Hyun, Jae Seog; Kwon, Oh-Young

    2010-08-01

    The purpose of this study was to examine the cerebral changes in high beta frequency oscillations (22-30 Hz) induced by sertraline and by audiovisual erotic stimuli in healthy adult males. Scalp electroencephalographies (EEGs) were conducted twice in 11 healthy, right-handed males, once before sertraline intake and again 4 hours thereafter. The EEGs included four sessions recorded sequentially while the subjects were resting, watching a music video, resting, and watching an erotic video for 3 minutes, 5 minutes, 3 minutes, and 5 minutes, respectively. We performed frequency-domain analysis using the EEGs with a distributed model of current-source analysis. The statistical nonparametric maps were obtained from the sessions of watching erotic and music videos (perotic stimuli decreased the current-source density of the high beta frequency band in the middle frontal gyrus, the precentral gyrus, the postcentral gyrus, and the supramarginal gyrus of the left cerebral hemisphere in the baseline EEGs taken before sertraline intake (perotic stimuli did not induce any changes in current-source distribution of the brain 4 hours after sertraline intake. It is speculated that erotic stimuli may decrease the function of the middle frontal gyrus, the precentral gyrus, the postcentral gyrus, and the supramarginal gyrus of the left cerebral hemisphere in healthy adult males. This change may debase the inhibitory control of the brain against erotic stimuli. Sertraline may reduce the decrement in inhibitory control.

  3. Atmospheric deposition of long-lived Beta radionuclides over the territory of Bulgaria during the last decades

    Energy Technology Data Exchange (ETDEWEB)

    Veleva, B. [National Institute of Meteorology and Hydrology, Bulgarian Academy of Sciences, Sofia (Bulgaria)

    2013-07-01

    The sources of atmospheric radioactivity are discussed and compared. Radon isotopes and their daughters' dominate the natural background of beta activity in the surface air. The man-made radionuclides, much of them beta emitters, started to contaminate regionally and globally the environment after 1940's due to the atmospheric nuclear bomb tests. Additional significant sources of technogenic radionuclides in the atmosphere were nuclear accidents with pronounced examples of Chernobyl and Fukushima. The Bulgarian network for atmospheric radioactivity monitoring has been developing since 1959 in the frame of the state Hydro-meteorological service, now National Institute of Meteorology and Hydrology. It includes daily measurements of aerosol beta activity and deposition immediately and 120h after the sampling. The time and space variations of deposited beta activity, based on long term data records are presented and impact assessment of the different sources is given. The role of precipitation in deposition of radionuclides is evaluated. (author)

  4. Beta-spectrometer with Si-detectors for the study of 144Ce-144Pr decays

    Science.gov (United States)

    Alexeev, I. E.; Bakhlanov, S. V.; Bazlov, N. V.; Chmel, E. A.; Derbin, A. V.; Drachnev, I. S.; Kotina, I. M.; Muratova, V. N.; Pilipenko, N. V.; Semyonov, D. A.; Unzhakov, E. V.; Yeremin, V. K.

    2018-05-01

    Here we present the specifications of a newly developed beta-spectrometer, based on full absorption Si(Li) detector and thin transmission detector, allowing one to perform efficient separation beta-radiation and accompanying X-rays and gamma radiation. Our method is based on registration of coincident events from both detectors. The spectrometer can be used for precision measurements of various beta-spectra, namely for the beta-spectrum shape study of 144Pr, which is considered to be an advantageous anti-neutrino source for sterile neutrino searches.

  5. The change of transforming growth factor {beta} 1 (TGF- {beta} 1) expression by melatonin in irradiated lung

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Seong Soon; Choi, Ihl Bohng [College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of)

    2005-09-15

    The changed expressions of TGF- {beta} 1, as a key cytokine in the fibrotic process, due to melatonin with potent antioxidative effects, were investigated in the irradiated lung using fibrosis-sensitive C57BL/6 mice. Female C57BL/6 mice were divided into control irradiation-only, and melatonin (300 mg/kg i.p. 1 hr before irradiation) pretreatment groups. The thoraces of the mice were irradiated with a single dose of 12 Gy. The mRNA expressions of TGF-{beta} 1 in the lung tissue 2 and 4 weeks after irradiation were quantified using semiquantitive RT-PCR, and the cellular origin and expression levels of TGF- {beta} 1 protein were identified using immunohistochemical staining. The relative mRNA expression levels in the irradiation-only and melatonin pretreatment group 2 and 4 weeks after irradiation were 1.92- and 1.80-fold ({rho} = 0.064) and 2.38- and 1.94-fold ({rho} = 0.004) increased, respectively compared to those in the control group. Increased expressions of TGF- {beta} 1 protein were prominently detected in regions of histopathological radiation injury, with alveolar macrophages and septal epithelial cells serving as important sources of TGF- {beta} 1 expression. At 2 and 4 weeks after irradiation, the expression levels of protein were 15.8% vs. 16.9% ({rho} = 0.565) and 36.1% vs. 25.7% ({rho} = 0.009), respectively. The mRNA and protein expressions of TGF- {beta} 1 in the lung tissue following thoracic irradiation with 12 Gy were significantly decreased by melatonin pretreatment at 4 weeks. These results indicate that melatonin may have a possible application as an antifibrotic agent in radiation-induced lung injury.

  6. Radioisotope Power Sources

    International Nuclear Information System (INIS)

    Culwell, J. P.

    1963-01-01

    The radioisotope power programme of the US Atomic Energy Commission has brought forth a whole new technology of the use of radioisotopes as energy sources in electric power generators. Radioisotope power systems are particularly suited for remote applications where long-lived, compact, reliable power is needed. Able to perform satisfactorily under extreme environmental conditions of temperature, sunlight and electromagnetic radiations, these ''atomic batteries'' are attractive power sources for remote data collecting devices, monitoring systems, satellites and other space missions. Radioisotopes used as fuels generally are either alpha or beta emitters. Alpha emitters are the preferable fuels but are more expensive and less available than beta fuels and are generally reserved for space applications. Beta fuels separated from reactor fission wastes are being used exclusively in land and sea applications at the present. It can be expected, however, that beta emitters such as stiontium-90 eventually will be used in space. Development work is being carried out on generators which will use mixed fission products as fuel. This fuel will be less expensive than the pure radioisotopes since the costs of isotope separation and purification are eliminated. Prototype thermoelectric generators, fuelled with strontium-90 and caesium-137, are now in operation or being developed for use in weather stations, marine navigation aids and deep sea monitoring devices. A plutonium-238 thermoelectric generator is in orbit operating as electric power source in a US Navy TRANSIT satellite. Generators are under development for use on US National Aeronautics and Space Administration missions. The large quantities of radioactivity involved in radioisotope power sources require that special attention be given to safety aspects of the units. Rigid safety requirements have been established and extensive tests have been conducted to insure that these systems can be employed without creating undue

  7. Effect of mixing rate on Beta-carotene production and extraction by dunaliella salina in two-phase bioreactors

    NARCIS (Netherlands)

    Hejazi, M.; Andrysiewicz, E.; Tramper, J.; Wijffels, R.H.

    2003-01-01

    beta-Carotene has many applications in the food, cosmetic, and pharmaceutical industries; Dunaliella salina is currently the main source for natural beta-carotene. We have investigated the effect of mixing rate and whether it leads to the facilitated release of beta-carotene from the cells of

  8. Assessment of affinities of beta-CIT, beta-CIT-FE, and beta-CIT-FP for monoamine transporters permanently expressed in cell lines

    International Nuclear Information System (INIS)

    Okada, Tomoya; Fujita, Masahiro; Shimada, Shoichi; Sato, Kohji; Schloss, Patrick; Watanabe, Yoshiyuki; Itoh, Yasushi; Tohyama, Masaya; Nishimura, Tsunehiko

    1998-01-01

    We investigated the effects of three cocaine analogs, beta-CIT (2-beta-carbomethoxy-3-beta-(4-iodophenyl)-tropane), beta-CIT-FE (2-beta-carbomethoxy-3-beta-(4-iodophenyl)-N-(2-fluoroethyl)-nortropane), and beta-CIT-FP (2-beta-carbomethoxy-3-beta-(4-iodophenyl)-N-(3-fluoropropyl)-nortropane), on the uptake of [ 3 H]dopamine(DA), serotonin(5-HT), and 1-norepinephrine (NE) using cell lines permanently expressing DA, 5-HT, and NE transporters, respectively, to determine their affinities for these three transporters. We generated cell lines stably expressing DA, 5-HT, and NE transporters, respectively, by the Chen-Okayama method, and then tested the abilities of (-)cocaine, beta-CIT, beta-CIT-FE, beta-CIT-FP, and clomipramine to inhibit the uptake of [ 3 H]DA, 5-HT, and 1-NE. Ki values of beta-CIT, beta-CIT-FE, and beta-CIT-FP for [ 3 H]DA, 5-HT, 1-NE uptake were 6, 29, and 33 nM, 91, 133, and 130 nM, and 28, 113 and 70 nM, respectively, whereas those of cocaine and clomipramine were 316, 581, and 176 nM and > 10,000, 437, and 851 nM, respectively. Beta-CIT, beta-CIT-FE, and beta-CIT-FP were shown to be potent DA, 5-HT, and NE uptake inhibitors. Beta-CIT and beta-CIT-FP were highly potent and selective dopamine uptake inhibitors, and therefore might be useful for imaging of DA transporter with single photon emission computed tomography (SPECT) or positron emission tomography (PET)

  9. Calibration of photon and beta ray sources used in brachytherapy. Guidelines on standardized procedures at Secondary Standards Dosimetry Laboratories (SSDLs) and hospitals

    International Nuclear Information System (INIS)

    2002-03-01

    It has generally been recognized that international harmonization in radiotherapy dosimetry is essential. Consequently, the IAEA has given much effort to this, for example by publishing a number of reports in the Technical Reports Series (TRS) for external beam dosimetry, most notably TRS-277 and more recently TRS-398. Both of these reports describe in detail the steps to be taken for absorbed dose determination in water and they are often referred to as 'dosimetry protocols'. Similar to TRS-277, it is expected that TRS-398 will be adopted or used as a model by a large number of countries as their national protocol. In 1996, the IAEA established a calibration service for low dose rate (LDR) 137 Cs brachytherapy sources, which is the most widely used source for treatment of gynecological cancer. To further enhance harmonization in brachytherapy dosimetry, the IAEA published in 1999 IAEA-TECDOC-1079 entitled 'Calibration of Brachytherapy Sources. Guidelines on Standardized Procedures for the Calibration of Brachytherapy Sources at Secondary Standard Dosimetry Laboratories (SSDLs) and Hospitals'. The report was well received and was distributed in a large number of copies to the members of the IAEA/WHO network of SSDLs and to medical physicists working with brachytherapy. The present report is an update of the aforementioned TECDOC. Whereas TECDOC-1079 described methods for calibrating brachytherapy sources with photon energies at or above those of 192 Ir, the current report has a wider scope in that it deals with standardization of calibration of all the most commonly used brachytherapy sources, including both photon and beta emitting sources. The latter sources have been in use for a few decades already, but their calibration methods have been unclear. Methods are also described for calibrating sources used in the rapidly growing field of cardiovascular angioplasty. In this application, irradiation of the vessel wall is done in an attempt to prevent restenosis after

  10. Measurement system study using beta radiation for determining different paper superficial density

    International Nuclear Information System (INIS)

    Vieira, Thais Molina; Madi Filho, Tufic

    2000-01-01

    Radioisotopes are used now in some areas of the industry. For quality control purposes, they are used in non-destructive analysis (NDA) which is applied to the materials examination verifying if they are adequate to the patterns demanded by technical rules or the market. Gamma, beta or neutron radiation sources may be used to do NDA, depending on material to be analyzed and the industrial process. In this work, the study of measurement system applied to quality control area was conceived and, in the evaluation of the material in test, a radioactive beta source was used. A system was designed and mounted, using a plastic scintillator detector developed in the laboratories of the Centro de Tecnologia das Radiacoes from IPEN-CNEN/SP. Two beta sources were used in the operational test: 90 Sr/ 90 Y and 204 Tl. Measures were obtained using several paper samples with different superficial density in g/m 2 . With the results, an equation correlating the relative activity with the superficial density in g/m 2 was established. (author)

  11. Characteristic tests of ionization chamber and GM counter survey meters for beta-rays, (2)

    International Nuclear Information System (INIS)

    Suga, Shin-ichi; Bingo, Kazuyoshi; Kajimoto, Yoichi

    1979-03-01

    To estimate a beta-ray absorbed dose rate of contaminated skin, measurements were done twice by a survey meter without and with a filter, keeping the distance from the contaminated skin surface to the survey meter at 10 mm. The absorbed dose rate was obtained multiplying a net reading (equals a reading of survey meter's indicator measured without the filter minus that measured with the filter) by a multiplying factor. Calibrations were made with reference plane sources of natural uranium, 198 Au and 204 Tl, varying their area. The five types of ionization chamber survey meters had nearly same multiplying factors when the diameter of source was larger than the diameter of the chamber cylinder. Estimation of the absorbed doses due to beta-emitting nuclides was possible when the measured value without filter was larger by 20% or more than that of with filter. In the case of small sources, the multiplying factor varied significantly with area of the source. The multiplying factors agreed within +-30% in the respective types i.e. manufacturers and in maximum beta-ray energies from 0.7 up to 2.5 MeV. In the source to detector distance of 1 cm +-0.2 cm, the multiplying factor varied within +-20%. The multiplying factor of a GM counter survey meter varied with beta-ray energy, the multiplying factor for uranium was 1/3 that of 204 Tl. (author)

  12. $\\beta$-decay studies using total-absorption spectroscopy

    CERN Document Server

    Algora, A; García-Borge, M J; Cano-Ott, D; Collatz, R; Courtin, S; Dessagne, P; Fraile-Prieto, L M; Gadea, A; Gelletly, W; Hellström, M; Janas, Z; Jungclaus, A; Kirchner, R; Karny, M; Le Scornet, G; Miehé, C; Maréchal, F; Moroz, F; Nacher, E; Poirier, E; Roeckl, E; Rubio, B; Rykaczewski, K; Taín, J L; Tengblad, O; Wittmann, V

    2004-01-01

    $\\beta$-decay experiments are a primary source of information for nuclear-structure studies and at the same time complementary to in- beam investigations of nuclei far from stability. Although both types of experiment are mainly based on $\\gamma$-ray spectroscopy, they face different experimental problems. The so-called " Pandemonium effect " is a critical problem in $\\beta$-decay if we are to test theoretically calculated transition probabilities. In this contribution we will present a solution to this problem using total absorption spectroscopy methods. We will also present some examples of experiments carried out with the Total Absorption Spectrometer (TAS) at GSI and describe a new device LUCRECIA recently installed at CERN.

  13. Performance of a parallel plate ionization chamber in beta radiation dosimetry

    International Nuclear Information System (INIS)

    Antonio, Patricia L.; Caldas, Linda V.E.

    2011-01-01

    A homemade parallel plate ionization chamber with graphite collecting electrode, and developed for use in mammography beams, was tested in relation to its usefulness in beta radiation dosimetry at the Calibration Laboratory of IPEN. Characterization tests of this ionization chamber were performed, using the Sr-90 + Y-90, Kr-85 and Pm-147 sources of a beta secondary standard system. The results of saturation, leakage current, stabilization time, response stability, linearity, angular dependence, and calibration coefficients are within the recommended limits of international recommendations that indicate that this chamber may be used for beta radiation dosimetry. (author)

  14. Performance of a parallel plate ionization chamber in beta radiation dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Antonio, Patricia L.; Caldas, Linda V.E., E-mail: patrilan@ipen.b, E-mail: lcaldas@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    A homemade parallel plate ionization chamber with graphite collecting electrode, and developed for use in mammography beams, was tested in relation to its usefulness in beta radiation dosimetry at the Calibration Laboratory of IPEN. Characterization tests of this ionization chamber were performed, using the Sr-90 + Y-90, Kr-85 and Pm-147 sources of a beta secondary standard system. The results of saturation, leakage current, stabilization time, response stability, linearity, angular dependence, and calibration coefficients are within the recommended limits of international recommendations that indicate that this chamber may be used for beta radiation dosimetry. (author)

  15. Radiation thickness gauge using beta particle sensitivity controlled open air corona streamer counter

    International Nuclear Information System (INIS)

    Fouad, L.; El-Hazek, S.; El-Araby, S.

    1999-01-01

    Beta particles have been used extensively in radio gauging applications when measurements of foil thicknesses are desired. Using beta particle open air corona streamer counter (point-grid-plane) as a thickness gauge is presented. This gauge consists of two similar counters with two similar Sr-90 beta sources. One counter-source combination is called standard unit, and the other counter-source combination is called measuring unit in which the required foil thickness can be measured by inserting it between the source and the counter. The signals from the counters are amplified with the same gain factor and the net difference between their responses is measured using specially designed electronic circuit. By this way any change that takes place in the operating medium (variation of parameters of open air i.e. temperature, humidity...etc) can similarly affect the two units, the errors in the measurements caused by them are cancelled, and the only response is due to the measured foil thickness. A theoretical model is suggested to explain and analyze the overall response of the gauge system and calculate the calibration thickness gauge constant. All theoretical findings are confirmed by experiments

  16. Biosynthesis and release of beta-endorphin-, N-acetyl beta-endorphin-, beta-endorphin-(1-27)-, and N-acetyl beta-endorphin-(1-27)-like peptides by rat pituitary neurointermediate lobe: beta-endorphin is not further processed by anterior lobe

    International Nuclear Information System (INIS)

    Liotta, A.S.; Yamaguchi, H.; Krieger, D.T.

    1981-01-01

    Continuous labeling and pulse-chase techniques were employed to study the synthesis and secretion of multiple forms of immunoreactive beta-endorphin by cultured dispersed rat anterior lobe cells and intact neurointermediate pituitary lobe. Intact neurointermediate lobes incorporated radiolabeled amino acids into four to six forms of immunoreactive beta-endorphin. Four of these forms were physicochemically similar to authentic beta-endorphin, N-acetylated beta-endorphin, beta-endorphin-(1-27), and N-acetylated beta-endorphin-(1-27). Pulse-chase studies indicated that a beta-lipotropin-like molecule served as a metabolic intermediate for a beta-endorphin-like molecule. As beta-endorphin-like material accumulated in the cell, some of it was N-acetylated (approximately 18% at 2 hr chase and approximately 65% at 18 hr chase). At later chase times, beta-endorphin-(1-27)- and N-acetylated beta-endorphin-(1-27)-like peptides were the predominant molecular species detected. All endorphin forms were detected in unlabeled tissue maintained in culture or tissue continuously labeled for 72 hr and were released into the medium under basal, stimulatory (10(-8) M norepinephrine), or inhibitory (10(-7) M dopamine) incubation conditions. In all cases, beta-endorphin-(1-27)-like species were the predominant forms (more than 70% of total) present in the cells and released into the medium. In contrast, approximately 90% of radiolabeled immunoreactive beta-endorphin extracted from anterior lobe cells and medium similarly incubated appeared to represent the authentic beta-endorphin molecule. Continuous labeling (72 hr) revealed the beta-lipotropin/beta-endorphin molar ratio to be approximately 4. We conclude that, in anterior lobe, most of the beta-endorphin is not processed further and is released intact, while in neurointermediate lobe, it serves as a biosynthetic intermediate

  17. Research Applications of Beta-Particle Techniques: Back-Scattering and X-Ray Excitation; Applications de l'irradiation beta dans la recherche: retrodiffusion et excitation de rayons X; Primenenie metodov beta-chastits v issledovatel'skoj rabote: obratnoe rasseyanie i vozbuzhdenie rentgenovskikh luchej; Aplicacion de la irradiacion beta en la investigacion: retrodispersion y excitacion de rayos X

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, R H [Los Alamos Scientific Laboratory, University of California, Los Alamos, NM (United States)

    1962-01-15

    Studies in this Laboratory during the past seven years have established precise relationships for the back-scattering of beta-particles and these methods have been supplemented by techniques using isotope-excited X-rays. Such X-ray techniques have received wide attention and in many cases have revolutionized industrial gauging practices. This report is concerned with applications to precise absorptiometry, thickness of films, the identification and quantitative estimation of substances by absorption-edge measurements, and to paper chromatography. In the latter, chromatograms can be evaluated by beta-absorption, by X-ray absorption, or by excitation of X-rays in the various zones by beta-bombardment. These alternative approaches are compared and evaluated. Some microchemical techniques have been examined, and, either by beta-absorption or by beta-excitation of X-rays, small amounts of substances can be identified and determined. The lower limits of detection are not as small as one can achieve by tracer techniques, but there are numerous advantages, the primary one being that one deals with sealed sources from which contamination is virtually impossible. For all these phenomena precise equations have been developed from the data - some empirical, and others substantially fundamental. It is interesting that these equations accurately predict optimum source parameters as established by other investigators both in the United States and abroad. It is believed that these techniques confirm the opinion that radioactive isotopes have tremendous scientific and technical promise. As far as X-ray sources are concerned, it may be said that everything in X-ray technology, other than crystal-structure elucidation, can be done more simply by these means. With multi-curie sources, even the latter may eventually be possible. (author) [French] Les etudes qui se poursuivent depuis sept ans au Laboratoire de Los Alamos ont permis d'etablir des rapports precis pour la retrodiffusion

  18. Time reversal violation in radiative beta decay: experimental plans

    Science.gov (United States)

    Behr, J. A.; McNeil, J.; Anholm, M.; Gorelov, A.; Melconian, D.; Ashery, D.

    2017-01-01

    Some explanations for the excess of matter over antimatter in the universe involve sources of time reversal violation (TRV) in addition to the one known in the standard model of particle physics. We plan to search for TRV in a correlation between the momenta of the beta, neutrino, and the radiative gamma sometimes emitted in nuclear beta decay. Correlations involving three (out of four) momenta are sensitive at lowest order to different TRV physics than observables involving spin, such as electric dipole moments and spin-polarized beta decay correlations. Such experiments have been done in radiative kaon decay, but not in systems involving the lightest generation of quarks. An explicit low-energy physics model being tested produces TRV effects in the Fermi beta decay of the neutron, tritium, or some positron-decaying isotopes. We will present plans to measure the TRV asymmetry in radiative beta decay of laser-trapped 38mK at better than 0.01 sensitivity, including suppression of background from positron annihilation. Supported by NSERC, D.O.E., Israel Science Foundation. TRIUMF receives federal funding via a contribution agreement with the National Research Council of Canada.

  19. Effects of sertraline on brain current source of the high beta frequency band: analysis of electroencephalography during audiovisual erotic stimulation in males with premature ejaculation.

    Science.gov (United States)

    Kwon, O Y; Kam, S C; Choi, J H; Do, J M; Hyun, J S

    2011-01-01

    To identify the effects of sertraline, a selective serotonin reuptake inhibitor, for the treatment of premature ejaculation (PE), changes in brain current-source density (CSD) of the high beta frequency band (22-30 Hz) induced by sertraline administration were investigated during audiovisual erotic stimulation. Eleven patients with PE (36.9±7.8 yrs) and 11 male volunteers (24.2±1.9 years) were enrolled. Scalp electroencephalography (EEG) was conducted twice: once before sertraline administration and then again 4 h after the administration of 50 mg sertraline. Statistical non-parametric maps were obtained using the EEG segments to detect the current-density differences in the high beta frequency bands (beta-3, 22-30 Hz) between the EEGs before and after sertraline administration in the patient group and between the patient group and controls after the administration of sertraline during the erotic video sessions. Comparing between before and after sertraline administration in the patients with PE, the CSD of the high beta frequency band at 4 h after sertraline administration increased significantly in both superior frontal gyri and the right medial frontal gyrus (P<0.01). The CSD of the beta-3 band of the patients with PE were less activated significantly in the middle and superior temporal gyrus, lingual and fusiform gyrus, inferior occipital gyrus and cuneus of the right cerebral hemisphere compared with the normal volunteers 4 h after sertraline administration (P<0.01). In conclusion, sertraline administration increased the CSD in both the superior frontal and right middle temporal gyrus in patients with PE. The results suggest that the increased neural activity in these particular cerebral regions after sertraline administration may be associated with inhibitory effects on ejaculation in patients with PE.

  20. Optimization of plastic scintillator thicknesses for online beta/gamma detection

    Directory of Open Access Journals (Sweden)

    Pourtangestani K.

    2012-04-01

    Full Text Available For efficient beta detection in a mixed beta gamma field, Monte Carlo simulation models have been built to optimize the thickness of a plastic scintillator, used in a whole body monitor. The simulation has been performed using the MCNP/X code for different thicknesses of plastic scintillator from 150 μm to 600 μm. The relationship between the thickness of the scintillator and the efficiency of the detector has been analyzed. For 150 μm thickness, an experimental investigation has been conducted with different beta sources at different positions on the scintillator and the counting efficiency of the unit has been measured. Evaluated data along with experimental ones have been discussed. A thickness of 300 μm to 500 μm has been found to be the optimum thickness for high efficiency beta detection in the presence of low energy gamma-rays.

  1. Purification of beta-acetylglucosaminase and beta-galactosidase from ram testis.

    Science.gov (United States)

    Caygill, J C; Roston, C P; Jevons, F R

    1966-02-01

    1. The presence of beta-galactosidase (EC 3.2.1.23) in an acetic acid extract of ram testis is reported. Some properties of the crude enzyme preparation were studied. 2. The purification of beta-acetylglucosaminase (EC 3.2.1.30) and of beta-galactosidase from the ram-testis extract by ammonium sulphate precipitation and chromatography on a CM-cellulose column is described. 3. The final purifications of the separated enzymes achieved were for the beta-acetylglucosaminase 35 times and for the beta-galactosidase 99 times. 4. The possibility of using DEAE-cellulose and Sephadex G-200 to purify the enzymes was investigated.

  2. Performance testing of beta dosimeters used at Department of Energy facilities

    International Nuclear Information System (INIS)

    Roberson, P.L.; Holbrook, K.L.; Pappin, J.L.

    1983-01-01

    A performance test based on the American national draft standard N13.11 was conducted for dosimeter systems in use at Department of Energy facilities. The large differences in dosimeter response found were due to use of different calibration source standards and different dosimeter designs. Differences in 90 Sr/ 90 Y calibrations were approximately 20% or less for all but one participant. The differences observed were attributed to variable thicknesses of dosimeter elements and variable source irradiation geometries. Improved beta calibration standards will result if irradiation specifications include acceptable ranges from the depth-dose characteristics. The low-energy beta responses observed were consistent with the thicknesses of dosimeter sensitive elements and overlying filtration

  3. Betting Against Beta

    DEFF Research Database (Denmark)

    Frazzini, Andrea; Heje Pedersen, Lasse

    We present a model with leverage and margin constraints that vary across investors and time. We find evidence consistent with each of the model’s five central predictions: (1) Since constrained investors bid up high-beta assets, high beta is associated with low alpha, as we find empirically for U...... of the BAB factor is low; (4) Increased funding liquidity risk compresses betas toward one; (5) More constrained investors hold riskier assets........S. equities, 20 international equity markets, Treasury bonds, corporate bonds, and futures; (2) A betting-against-beta (BAB) factor, which is long leveraged low beta assets and short high-beta assets, produces significant positive risk-adjusted returns; (3) When funding constraints tighten, the return...

  4. Conversion of beta-methylbutyric acid to beta-hydroxy-beta-methylbutyric acid by Galactomyces reessii.

    OpenAIRE

    Lee, I Y; Nissen, S L; Rosazza, J P

    1997-01-01

    beta-Hydroxy-beta-methylbutyric acid (HMB) has been shown to increase strength and lean mass gains in humans undergoing resistance-exercise training. HMB is currently marketed as a calcium salt of HMB, and thus, environmentally sound and inexpensive methods of manufacture are being sought. This study investigates the microbial conversion of beta-methylbutyric acid (MBA) to HMB by cultures of Galactomyces reessii. Optimal concentrations of MBA were in the range of 5 to 20 g/liter for HMB produ...

  5. Forward-Looking Betas

    DEFF Research Database (Denmark)

    Christoffersen, Peter; Jacobs, Kris; Vainberg, Gregory

    Few issues are more important for finance practice than the computation of market betas. Existing approaches compute market betas using historical data. While these approaches differ in terms of statistical sophistication and the modeling of the time-variation in the betas, they are all backward......-looking. This paper introduces a radically different approach to estimating market betas. Using the tools in Bakshi and Madan (2000) and Bakshi, Kapadia and Madan (2003) we employ the information embedded in the prices of individual stock options and index options to compute our forward-looking market beta...

  6. The calculation of the detection efficiency in the calibration of gross alpha-beta systems

    International Nuclear Information System (INIS)

    Marian Romeo Calin; Ileana Radulescu; Alexandru Erminiu Druker

    2013-01-01

    This paper presents a method for efficiency calibration of a measuring alpha-beta system PROTEAN ORTEC, MPC-2000-DP, using standard radioactive sources. The system is used to measure gross alpha-beta activity concentrations in environmental samples. The calculated efficiencies of detection were subsequently introduced in the system for two working geometries: measuring geometry-gross alpha-beta ε α g = 31,37 ± 0.25 (%)-the alpha efficiency and ε β g 44.94 ± 0.69 (%)-the beta efficiency, where the spillover factor is X talk g = 25.59 ± 0.50 (%) and measuring geometry up alpha-beta ε α u 36.23 ± 0.29 (%)-the alpha efficiency and ε β u = 48.53 ± 0.74 (%)-the beta efficiency, where the spillover factor is X talk u 31.08 ± 0.60 (%). (author)

  7. The Mechanism of $\\beta$-Delayed Two-Proton Emission

    CERN Multimedia

    2002-01-01

    The nucleus $^{31}$Ar seems to be the most prolific ${\\beta}$-2p precursor known to date and is at the same time the one with the largest production yields at ISOLDE, where the most sensitive experiments can be done. Our purpose with this experiment is to study the ${\\beta}$-2p branches in detail, search for ${\\beta}$-3p events, place them in the decay scheme and obtain information on the decay mechanism for ${\\beta}$-2p via the energy distribution and the angular correlation between the two protons. As a by product we shall also resolve existing inconsistencies in the level scheme.\\\\ \\\\ The nucleus $^{31}$Ar, produced in a cold plasma ion source unit by the impact of a 1 GeV proton beam of 0.5 Hz frequency, had an average yield over one week of 1.5 $^{31}$Ar atoms/s. The beam passed through the central hole of an annular Si detector ($\\Omega$ = 4.3~\\%) and stopped in a thin carbon foil tilted 45$^o$ with respect to the beam direction. A 70~\\% coaxial HPGe-detector ($\\Omega$~=~7.4~\\%) was located opposite to ...

  8. Self Absorbed Fraction for Electrons and Beta Particles in Small Spherical Volumes

    International Nuclear Information System (INIS)

    Grosev, D.

    2003-01-01

    Absorbed fraction and target organ mass are important parameters of internal dosimetry calculations that define the geometry of the system. Standard MIRD (Medical Internal Radiation Dosimetry) formalism assumes that the absorbed fraction for non-penetrating radiations (e.g., electrons, beta particles) is 1. This may not be correct in cases where dimensions of organs/tissues are comparable with the ranges of electrons/beta particles. Such is the case for example in radiodine ablation of thyroid remnant tissue. In this work the self-absorbed fraction (source and target volumes are the same) for monoenergetic electrons and beta particles is calculated for small spherical volumes of various sizes and unit density. Absorbed fraction can be expressed as an integral of the product of two quantities: (a) Scaled beta dose point kernel (mean absorbed dose rate per activity of the point source in infinite homogenous medium), F β ; (b) special geometrical reduction factor (GRF). F β is calculated using EGS4 Monte Carlo (MC) code for transport of electrons and photons. MC source code calculates the deposition of energy inside concentric spherical shells around the isotropic point source of electrons/beta particles in infinite medium (water). Shell thickness was δr=0.02·X 90 , where X 90 represents the radius of the sphere inside which 90% of the source energy is absorbed. Number of concentric spherical shells was 100, 10000 electron histories were started in each program run, and 10 runs were repeated for statistical reason. Numerical integration of the product of F β , calculated by MC program, and GRF for sphere was done using Simpson method. Absorbed fractions were calculated for spheres with mass from 0.01-20 g (r = 0.13 - 1.68 cm). Results are given for monoenergetic electrons with kinetic energy T=0.2, 0.4, 1.0 MeV, and for three beta emitters 1 31I , 3 2P , 9 0Y . For quantitative dosimetric protocols in radioiodine ablation therapy, results for 1 31I are of

  9. Computational methods for analyzing the transmission characteristics of a beta particle magnetic analysis system

    Science.gov (United States)

    Singh, J. J.

    1979-01-01

    Computational methods were developed to study the trajectories of beta particles (positrons) through a magnetic analysis system as a function of the spatial distribution of the radionuclides in the beta source, size and shape of the source collimator, and the strength of the analyzer magnetic field. On the basis of these methods, the particle flux, their energy spectrum, and source-to-target transit times have been calculated for Na-22 positrons as a function of the analyzer magnetic field and the size and location of the target. These data are in studies requiring parallel beams of positrons of uniform energy such as measurement of the moisture distribution in composite materials. Computer programs for obtaining various trajectories are included.

  10. Enantioselective synthesis of alpha,beta-disubstituted-beta-amino acids.

    Science.gov (United States)

    Sibi, Mukund P; Prabagaran, Narayanasamy; Ghorpade, Sandeep G; Jasperse, Craig P

    2003-10-01

    Highly diastereoselective and enantioselective addition of N-benzylhydroxylamine to imides 17 and 20-30 produces alpha,beta-trans-disubstituted N-benzylisoxazolidinones 19 and 31-41. These reactions proceed in 60-96% ee with 93-99% de's using 5 mol % of Mg(NTf2)2 and ligand 18. The product isoxazolidinones can be hydrogenolyzed directly to provide alpha,beta-disubstituted-beta-amino acids.

  11. [Effect of sulfonation of polyethersulfone sheets on the adsorption of beta2-microglobulin].

    Science.gov (United States)

    Cheng, Liping; Sun, Shudong; Yue, Yilun; Huang, Jia; Mao, Huayi; Liang, Bo

    2005-06-01

    This study was performed to evaluate the adsorption of beta2-microglobulin(beta2 M) by blood dialysis membrane materials which are polyethersulfone (PES), sulfonated polyethersulfones, (PES-SO3Na-I and PES-SO3Na-I ) in vitro incubated in human serum and radiolabeled beta2M (125I-beta2 M) solution respectively. In these experiments, the materials were incubated in 125I-beta2 M solution and human serum at the appointed time ranging from 15 minutes to four hours at 37 degrees C, and then the amounts of 125I-beta2M and serum beta2M adsorbed by materials were measured by radioimmunoassay (RIA). In the 125I-beta2 M system, amounts of 125I-beta2M adsorbed by the materials decreased in sequence of PES-SO3 Na-II > PES-SO3Na-I > PES. In the serum system, amounts of beta2M adsorbed reached maximums at 30 minutes and the final adsorptions decreased in sequence of PES-SO3Na-II > PES-SO3Na-I > PES. Sulfonated PES removes beta2M more than PES does and the adsorption of beta2M increases with the increase in the degree of sulfonation. Its ability to remove significant amount of beta2M may result in less beta2M available for incorporation into amyloid. The use of PES-SO3Na membranes lessens the likelihood of dialysis-related amyloidosis (DRA) development, which remains a major source of morbidity for patients treated with long-term hemodialysis.

  12. Clinical Significance of Retinoic Acid Receptor Beta Promoter Methylation in Prostate Cancer: A Meta-Analysis.

    Science.gov (United States)

    Dou, MengMeng; Zhou, XueLiang; Fan, ZhiRui; Ding, XianFei; Li, LiFeng; Wang, ShuLing; Xue, Wenhua; Wang, Hui; Suo, Zhenhe; Deng, XiaoMing

    2018-01-01

    Retinoic acid receptor beta (RAR beta) is a retinoic acid receptor gene that has been shown to play key roles during multiple cancer processes, including cell proliferation, apoptosis, migration and invasion. Numerous studies have found that methylation of the RAR beta promoter contributed to the occurrence and development of malignant tumors. However, the connection between RAR beta promoter methylation and prostate cancer (PCa) remains unknown. This meta-analysis evaluated the clinical significance of RAR beta promoter methylation in PCa. We searched all published records relevant to RAR beta and PCa in a series of databases, including PubMed, Embase, Cochrane Library, ISI Web of Science and CNKI. The rates of RAR beta promoter methylation in the PCa and control groups (including benign prostatic hyperplasia and normal prostate tissues) were summarized. In addition, we evaluated the source region of available samples and the methods used to detect methylation. To compare the incidence and variation in RAR beta promoter methylation in PCa and non-PCa tissues, the odds ratio (OR) and 95% confidence interval (CI) were calculated accordingly. All the data were analyzed with the statistical software STATA 12.0. Based on the inclusion and exclusion criteria, 15 articles assessing 1,339 samples were further analyzed. These data showed that the RAR beta promoter methylation rates in PCa tissues were significantly higher than the rates in the non-PCa group (OR=21.65, 95% CI: 9.27-50.57). Subgroup analysis according to the source region of samples showed that heterogeneity in Asia was small (I2=0.0%, P=0.430). Additional subgroup analysis based on the method used to detect RAR beta promoter methylation showed that the heterogeneity detected by MSP (methylation-specific PCR) was relatively small (I2=11.3%, P=0.343). Although studies reported different rates for RAR beta promoter methylation in PCa tissues, the total analysis demonstrated that RAR beta promoter methylation

  13. Clinical Significance of Retinoic Acid Receptor Beta Promoter Methylation in Prostate Cancer: A Meta-Analysis

    Directory of Open Access Journals (Sweden)

    MengMeng Dou

    2018-03-01

    Full Text Available Background/Aims: Retinoic acid receptor beta (RAR beta is a retinoic acid receptor gene that has been shown to play key roles during multiple cancer processes, including cell proliferation, apoptosis, migration and invasion. Numerous studies have found that methylation of the RAR beta promoter contributed to the occurrence and development of malignant tumors. However, the connection between RAR beta promoter methylation and prostate cancer (PCa remains unknown. This meta-analysis evaluated the clinical significance of RAR beta promoter methylation in PCa. Materials and Methods: We searched all published records relevant to RAR beta and PCa in a series of databases, including PubMed, Embase, Cochrane Library, ISI Web of Science and CNKI. The rates of RAR beta promoter methylation in the PCa and control groups (including benign prostatic hyperplasia and normal prostate tissues were summarized. In addition, we evaluated the source region of available samples and the methods used to detect methylation. To compare the incidence and variation in RAR beta promoter methylation in PCa and non-PCa tissues, the odds ratio (OR and 95% confidence interval (CI were calculated accordingly. All the data were analyzed with the statistical software STATA 12.0. Results: Based on the inclusion and exclusion criteria, 15 articles assessing 1,339 samples were further analyzed. These data showed that the RAR beta promoter methylation rates in PCa tissues were significantly higher than the rates in the non-PCa group (OR=21.65, 95% CI: 9.27-50.57. Subgroup analysis according to the source region of samples showed that heterogeneity in Asia was small (I2=0.0%, P=0.430. Additional subgroup analysis based on the method used to detect RAR beta promoter methylation showed that the heterogeneity detected by MSP (methylation-specific PCR was relatively small (I2=11.3%, P=0.343. Conclusion: Although studies reported different rates for RAR beta promoter methylation in PCa

  14. In-trap decay spectroscopy for {beta}{beta} decays

    Energy Technology Data Exchange (ETDEWEB)

    Brunner, Thomas

    2011-01-18

    The presented work describes the implementation of a new technique to measure electron-capture (EC) branching ratios (BRs) of intermediate nuclei in {beta}{beta} decays. This technique has been developed at TRIUMF in Vancouver, Canada. It facilitates one of TRIUMF's Ion Traps for Atomic and Nuclear science (TITAN), the Electron Beam Ion Trap (EBIT) that is used as a spectroscopy Penning trap. Radioactive ions, produced at the radioactive isotope facility ISAC, are injected and stored in the spectroscopy Penning trap while their decays are observed. A key feature of this technique is the use of a strong magnetic field, required for trapping. It radially confines electrons from {beta} decays along the trap axis while X-rays, following an EC, are emitted isotropically. This provides spatial separation of X-ray and {beta} detection with almost no {beta}-induced background at the X-ray detector, allowing weak EC branches to be measured. Furthermore, the combination of several traps allows one to isobarically clean the sample prior to the in-trap decay spectroscopy measurement. This technique has been developed to measure ECBRs of transition nuclei in {beta}{beta} decays. Detailed knowledge of these electron capture branches is crucial for a better understanding of the underlying nuclear physics in {beta}{beta} decays. These branches are typically of the order of 10{sup -5} and therefore difficult to measure. Conventional measurements suffer from isobaric contamination and a dominating {beta} background at theX-ray detector. Additionally, X-rays are attenuated by the material where the radioactive sample is implanted. To overcome these limitations, the technique of in-trap decay spectroscopy has been developed. In this work, the EBIT was connected to the TITAN beam line and has been commissioned. Using the developed beam diagnostics, ions were injected into the Penning trap and systematic studies on injection and storage optimization were performed. Furthermore, Ge

  15. BetaTPred: prediction of beta-TURNS in a protein using statistical algorithms.

    Science.gov (United States)

    Kaur, Harpreet; Raghava, G P S

    2002-03-01

    beta-turns play an important role from a structural and functional point of view. beta-turns are the most common type of non-repetitive structures in proteins and comprise on average, 25% of the residues. In the past numerous methods have been developed to predict beta-turns in a protein. Most of these prediction methods are based on statistical approaches. In order to utilize the full potential of these methods, there is a need to develop a web server. This paper describes a web server called BetaTPred, developed for predicting beta-TURNS in a protein from its amino acid sequence. BetaTPred allows the user to predict turns in a protein using existing statistical algorithms. It also allows to predict different types of beta-TURNS e.g. type I, I', II, II', VI, VIII and non-specific. This server assists the users in predicting the consensus beta-TURNS in a protein. The server is accessible from http://imtech.res.in/raghava/betatpred/

  16. Roughing up Beta

    DEFF Research Database (Denmark)

    Bollerslev, Tim; Li, Sophia Zhengzi; Todorov, Viktor

    -section. An investment strategy that goes long stocks with high jump betas and short stocks with low jump betas produces significant average excess returns. These higher risk premiums for the discontinuous and overnight market betas remain significant after controlling for a long list of other firm characteristics......Motivated by the implications from a stylized equilibrium pricing framework, we investigate empirically how individual equity prices respond to continuous, or \\smooth," and jumpy, or \\rough," market price moves, and how these different market price risks, or betas, are priced in the cross......-section of expected returns. Based on a novel highfrequency dataset of almost one-thousand individual stocks over two decades, we find that the two rough betas associated with intraday discontinuous and overnight returns entail significant risk premiums, while the intraday continuous beta is not priced in the cross...

  17. Plasma beta-endorphin, beta-lipotropin and corticotropin in polycystic ovarian disease.

    Science.gov (United States)

    Laatikainen, T; Salminen, K; Virtanen, T; Apter, D

    1987-04-01

    In 9 women with polycystic ovarian disease (PCOD) and in 11 control subjects at the follicular phase of the normal cycle, blood samples were collected at 15-min intervals during a 2 h period of bed rest for the assay of beta-endorphin, beta-lipotropin, corticotropin, cortisol and prolactin. During the study period, the plasma levels of these hormones decreased more significantly in the PCOD than in the control group, suggesting that the PCOD patients had a more significant stress response to the puncture of the vein than the control subjects. The second hour of the study period was considered to represent resting levels of hormones. The mean resting levels (+/- S.E.) of the hormones between the PCOD and control groups, respectively, were as follows: beta-E, 2.0 +/- 0.4 vs. 1.1 +/- 0.1 pmol/l, p less than 0.05; beta-LPH, 3.4 +/- 0.6 vs. 2.1 +/- 0.5 pmol/l, N.S.; corticotropin, 2.0 +/- 0.3 vs. 1.1 +/- 0.5 pmol/l, p less than 0.05; cortisol, 176 +/- 24 vs. 128 +/- 16, N.S.; and prolactin; 3.9 +/- 0.6 vs. 5.6 +/- 1.2 ng/ml, N.S. These results confirm the previous findings on increased circulating levels of beta-E in PCOD. A concomitant increase of the plasma level of corticotropin suggests that the basal secretion of both beta-E and corticotropin from the anterior pituitary gland is increased in women with PCOD.

  18. On Fuzzy {beta}-I-open sets and Fuzzy {beta}-I-continuous functions

    Energy Technology Data Exchange (ETDEWEB)

    Keskin, Aynur [Department of Mathematics, Faculty of Science and Arts, Selcuk University, Campus, 42075 Konya (Turkey)], E-mail: akeskin@selcuk.edu.tr

    2009-11-15

    In this paper, first of all we obtain some properties and characterizations of fuzzy {beta}-I-open sets. After that, we also define the notion of {beta}-I-closed sets and obtain some properties. Lastly, we introduce the notions of fuzzy {beta}-I-continuity with the help of fuzzy {beta}-I-open sets to obtain decomposition of fuzzy continuity.

  19. Clusters of conserved beta cell marker genes for assessment of beta cell phenotype

    DEFF Research Database (Denmark)

    Martens, Geert A; Jiang, Lei; Hellemans, Karine H

    2011-01-01

    The aim of this study was to establish a gene expression blueprint of pancreatic beta cells conserved from rodents to humans and to evaluate its applicability to assess shifts in the beta cell differentiated state. Genome-wide mRNA expression profiles of isolated beta cells were compared to those...... of a large panel of other tissue and cell types, and transcripts with beta cell-abundant and -selective expression were identified. Iteration of this analysis in mouse, rat and human tissues generated a panel of conserved beta cell biomarkers. This panel was then used to compare isolated versus laser capture...... microdissected beta cells, monitor adaptations of the beta cell phenotype to fasting, and retrieve possible conserved transcriptional regulators....

  20. N-Benzylhydroxylamine addition to beta-aryl enoates. Enantioselective synthesis of beta-aryl-beta-amino acid precursors

    Science.gov (United States)

    Sibi; Liu

    2000-10-19

    Chiral Lewis acid catalyzed N-benzylhydroxylamine addition to pyrrolidinone-derived enoates afforded beta-aryl-beta-amino acid derivatives in high enantiomeric purity with moderate to very good chemical efficiency.

  1. Beta Emission and Bremsstrahlung

    Energy Technology Data Exchange (ETDEWEB)

    Karpius, Peter Joseph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-11-13

    Bremsstrahlung is continuous radiation produced by beta particles decelerating in matter; different beta emitters have different endpoint energies; high-energy betas interacting with high-Z materials will more likely produce bremsstrahlung; depending on the data, sometimes all you can say is that a beta emitter is present.

  2. Personal monitoring for external sources of beta and low energy photon radiations

    Energy Technology Data Exchange (ETDEWEB)

    Christensen, P.; Herbaut, Y.; Marshall, T.O.

    1987-01-01

    In general, the dosemeters currently used for personal monitoring of beta and low energy photon doses suffer from an energy threshold problem because the detector and/or filter is too thick. Furthermore, current non-tissue-equivalent dosemeters, e.g. film dosemeters, are not provided with the filters needed to evaluate beta ray and low energy photon doses separately. To improve the present state of film dosemeters the thickness of the film wrapping paper should be reduced significantly and the badge should be provided with a number of pairs of thin filters. The dose evaluation from such a dosemeter is, however, complex and inaccurate and it seems unlikely that the required improvement is achievable at a reasonable cost. Improvement of tissue-equivalent dosemeters is possible by further development of multi-element dosemeters and thin detectors. The multi-element method has the advantage of using existing detectors, however the dose estimation is encumbered with high random error and the dosemeter design may become prohibitively expensive. The use of thin tissue-equivalent detectors implies a very simple badge design and an inherently accurate and uncomplicated dose evaluation. The development of adequate, thin, tissue-equivalent detectors suited for automated processing should therefore be encouraged.

  3. Personal monitoring for external sources of beta and low energy photon radiations

    International Nuclear Information System (INIS)

    Christensen, P.; Herbaut, Y.; Marshall, T.O.

    1987-01-01

    In general, the dosemeters currently used for personal monitoring of beta and low energy photon doses suffer from an energy threshold problem because the detector and/or filter is too thick. Furthermore, current non-tissue-equivalent dosemeters, e.g. film dosemeters, are not provided with the filters needed to evaluate beta ray and low energy photon doses separately. To improve the present state of film dosemeters the thickness of the film wrapping paper should be reduced significantly and the badge should be provided with a number of pairs of thin filters. The dose evaluation from such a dosemeter is, however, complex and inaccurate and it seems unlikely that the required improvement is achievable at a reasonable cost. Improvement of tissue-equivalent dosemeters is possible by further development of multi-element dosemeters and thin detectors. The multi-element method has the advantage of using existing detectors, however the dose estimation is encumbered with high random error and the dosemeter design may become prohibitively expensive. The use of thin tissue-equivalent detectors implies a very simple badge design and an inherently accurate and uncomplicated dose evaluation. The development of adequate, thin, tissue-equivalent detectors suited for automated processing should therefore be encouraged. (author)

  4. Nuclear Matrix Elements for the $\\beta\\beta$ Decay of the $^{76}$Ge

    CERN Document Server

    Brown, B A; Horoi, M

    2015-01-01

    The nuclear matrix elements for two-neutrino double-beta (2 n$\\beta\\beta$ ) and zero-neutrino double-beta (0 n$\\beta\\beta$) decay of 76 Ge are evaluated in terms of the configuration interaction (CI), quasiparticle random phase approximation (QRPA) and interacting boson model (IBM) methods. We show that the decomposition of the matrix elements in terms of interemediate states in 74 Ge is dominated by ground state of this nucleus. We consider corrections to the CI results that arise from configurations admixtures involving orbitals out-side of the CI configuration space by using results from QRPA, many-body-perturbation theory, and the connections to related observables. The CI two-neutrino matrix element is reduced due to the inclusion of spin-orbit partners, and to many-body correlations connected with Gamow-Teller beta decay. The CI zero-neutrino matrix element for the heavy neutrino is enhanced due to particle-particle correlations that are connected with the odd-even oscillations in the nuclear masse...

  5. A digital instrument for nondestructive measurements of coating thicknesses by beta backscattering

    Science.gov (United States)

    Farcasiu, D. M.; Apostolescu, T.; Bozdog, H.; Badescu, E.; Bohm, V.; Stanescu, S. P.; Jianu, A.; Bordeanu, C.; Cracium, M. V.

    1992-02-01

    The elements of nondestructive gauging of coatings applied on various metal bases are presented. The intensity of the backscattered beta radiations is related to the thickness of the coating. With a fixed measuring geometry and radioactive sources (147Pm, 204Tl, 90Sr+90Y) the intensity of the backscattered beta particles is dependent on the following parameters: coating thickness, atomic number of the coating material and of the base, the beta particle energy and the surface finish. It can be used for the measurement of a wide range of coating thicknesses provided that the difference between the coating and the support atomic numbers is at least 20%. Fields of application include electronics, electrotechnique and so on.

  6. A digital instrument for nondestructive measurements of coating thicknesses by beta backscattering

    International Nuclear Information System (INIS)

    Farcasiu, D.M.; Apostolescu, T.; Bozdog, H.; Badescu, E.; Bohm, V.; Stanescu, S.P.; Jianu, A.; Bordeanu, C.; Craciun, M.V.

    1992-01-01

    The elements of nondestructive gauging of coatings applied on various metal bases are presented. The intensity of the backscattered beta radiations is related to the thickness of the coating. With a fixed measuring geometry and radioactive sources ( 147 Pm, 204 Tl, 90 Sr+ 90 Y) the intensity of the backscattered beta particles is dependent on the following parameters: Coating thickness, atomic number of the coating material and of the base, the beta particle energy and the surface finish. It can be used for the measurement of a wide range of coating thicknesses provided that the difference between the coating and the support atomic numbers is at least 20%. Fields of application include electronics, electrotechnique and so on. (orig.)

  7. NADPH-dependent glutamate dehydrogenase in Penicillium chrysogenum is involved in regulation of beta-lactam production

    DEFF Research Database (Denmark)

    Thykær, Jette; Kildegaard, Kanchana Rueksomtawin; Noorman, H.

    2008-01-01

    was detected in either of the Delta gdhA strains. Supplementation with glutamate restored growth but no beta-lactam production was detected for the constructed strains. Cultures with high ammonium concentrations (repressing conditions) and with proline as nitrogen source (de-repressed conditions) showed......The interactions between the ammonium assimilatory pathways and beta-lactam production were investigated by disruption of the NADPH-dependent glutamate dehydrogenase gene (gdhA) in two industrial beta-lactam-producing strains of Penicillium chrysogenum. The strains used were an adipoyl-7-ADCA...... continued beta-lactam production for the reference strains whereas the Delta gdhA strains remained non-productive under all conditions. By overexpressing the NAD-dependent glutamate dehydrogenase, the specific growth rate could be restored, but still no beta-lactam production was detected. The results...

  8. Production of beta-xylanase and beta-xylosidase by the extremely halophilic archaeon Halorhabdus utahensis

    DEFF Research Database (Denmark)

    Wainø, M.; Ingvorsen, K.

    2003-01-01

    -xylosidase stabilities, approximately 55% and 83% of the initial beta-xylanase and beta-xylosidase activities, respectively, remained after 24 h incubation at 20% NaCl. The enzymes were also shown to be slightly thermophilic: P-xylanase activity exhibiting two optima at 55degrees and 70degreesC, while beta......The extremely halophilic archaeon, Halorhabdus utahensis, isolated from the Great Salt Lake, Utah, produced beta-xylanase and beta-xylosidase activities. Both enzymes were active over a broad NaCl range from near zero to 30% NaCl when tested with culture broth. A broad NaCl optimum was observed...... for beta-xylanase activity between 5% and 15% NaCl, while beta-xylosidase activity was highest at 5% NaCl. Almost half of the maximum activities remained at 27%-30% NaCl for both enzyme activities. When dialyzed culture supernatant and culture broth were employed for determination of beta-xylanase and beta...

  9. Role of beta-adrenoceptors in memory consolidation: beta3-adrenoceptors act on glucose uptake and beta2-adrenoceptors on glycogenolysis.

    Science.gov (United States)

    Gibbs, Marie E; Hutchinson, Dana S; Summers, Roger J

    2008-09-01

    Noradrenaline, acting via beta(2)- and beta(3)-adrenoceptors (AR), enhances memory formation in single trial-discriminated avoidance learning in day-old chicks by mechanisms involving changes in metabolism of glucose and/or glycogen. Earlier studies of memory consolidation in chicks implicated beta(3)- rather than beta(2)-ARs in enhancement of memory consolidation by glucose, but did not elucidate whether stimulation of glucose uptake or of glycolysis was responsible. This study examines the role of glucose transport in memory formation using central injection of the nonselective facilitative glucose transporter (GLUT) inhibitor cytochalasin B, the endothelial/astrocytic GLUT-1 inhibitor phloretin and the Na(+)/energy-dependent endothelial glucose transporter (SGLT) inhibitor phlorizin. Cytochalasin B inhibited memory when injected into the mesopallium (avian cortex) either close to or between 25 and 45 min after training, whereas phloretin and phlorizin only inhibited memory at 30 min. This suggested that astrocytic/endothelial (GLUT-1) transport is critical at the time of consolidation, whereas a different transporter, probably the neuronal glucose transporter (GLUT-3), is important at the time of training. Inhibition of glucose transport by cytochalasin B, phloretin, or phlorizin also interfered with beta(3)-AR-mediated memory enhancement 20 min posttraining, whereas inhibition of glycogenolysis interfered with beta(2)-AR agonist enhancement of memory. We conclude that in astrocytes (1) activities of both GLUT-1 and SGLT are essential for memory consolidation 30 min posttraining; (2) neuronal GLUT-3 is essential at the time of training; and (3) beta(2)- and beta(3)-ARs consolidate memory by different mechanisms; beta(3)-ARs stimulate central glucose transport, whereas beta(2)-ARs stimulate central glycogenolysis.

  10. Low-beta investment strategies

    OpenAIRE

    Korn, Olaf; Kuntz, Laura-Chloé

    2015-01-01

    This paper investigates investment strategies that exploit the low-beta anomaly. Although the notion of buying low-beta stocks and selling high-beta stocks is natural, a choice is necessary with respect to the relative weighting of high-beta stocks and low-beta stocks in the investment portfolio. Our empirical results for US large-cap stocks show that this choice is very important for the risk-return characteristics of the resulting portfolios and their sensitivities to common risk factors. W...

  11. Ellagic acid promotes A{beta}42 fibrillization and inhibits A{beta}42-induced neurotoxicity

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Ying [Department of Histology and Embryology, College of Basic Medical Science, China Medical University, Shenyang 110001 (China); Tsinghua University School of Medicine, Haidian District, Beijing 100084 (China); Yang, Shi-gao; Du, Xue-ting; Zhang, Xi; Sun, Xiao-xia; Zhao, Min [Tsinghua University School of Medicine, Haidian District, Beijing 100084 (China); Sun, Gui-yuan, E-mail: sungy2004@sohu.com [Department of Histology and Embryology, College of Basic Medical Science, China Medical University, Shenyang 110001 (China); Liu, Rui-tian, E-mail: rtliu@tsinghua.edu.cn [Tsinghua University School of Medicine, Haidian District, Beijing 100084 (China)

    2009-12-25

    Smaller, soluble oligomers of {beta}-amyloid (A{beta}) play a critical role in the pathogenesis of Alzheimer's disease (AD). Selective inhibition of A{beta} oligomer formation provides an optimum target for AD therapy. Some polyphenols have potent anti-amyloidogenic activities and protect against A{beta} neurotoxicity. Here, we tested the effects of ellagic acid (EA), a polyphenolic compound, on A{beta}42 aggregation and neurotoxicity in vitro. EA promoted A{beta} fibril formation and significant oligomer loss, contrary to previous results that polyphenols inhibited A{beta} aggregation. The results of transmission electron microscopy (TEM) and Western blot displayed more fibrils in A{beta}42 samples co-incubated with EA in earlier phases of aggregation. Consistent with the hypothesis that plaque formation may represent a protective mechanism in which the body sequesters toxic A{beta} aggregates to render them harmless, our MTT results showed that EA could significantly reduce A{beta}42-induced neurotoxicity toward SH-SY5Y cells. Taken together, our results suggest that EA, an active ingredient in many fruits and nuts, may have therapeutic potential in AD.

  12. Highly effective portable beta spectrometer for precise depth selective electron Moessbauer spectroscopy

    International Nuclear Information System (INIS)

    Aldiyarov, N.U.; Kadyrzhanov, K.K.; Seytimbetov, A.M.; Zhdanov, V.S.

    2007-01-01

    Full text: More broad application of the nuclear-physical method of precise Depth Selective Electron Moessbauer Spectroscopy (DS EMS) is limited by insufficient accessibility of highly-effective beta spectrometers with acceptable resolution. It should be mentioned that the method DS EMS is realized at a combined installation that consists of a highly-effective beta spectrometer and a conventional portable nuclear gamma-resonance spectrometer. Yet few available beta spectrometers have sophisticated design and controlling; in most cases they are cumbersome. All the attempts to simplify beta spectrometers resulted in noticeable worsening of depth resolution for the DS EMS method making the measurements non precise. There is currently an obvious need in a highly-effective portable easily controlled beta spectrometer. While developing such portable beta spectrometer, it is more promising to use as basis a simpler spectrometer, which has ratio of sample size to spectrometer size of about five times. The paper presents an equal-arm version of a highly-effective portable beta spectrometer with transverse heterogeneous sector magnetic field that assures double focusing. The spectrometer is equipped with a large-area non-equipotential source (a sample under investigation) and a position-sensitive detector. This portable spectrometer meets all requirements for achievement of the DS EMS depth resolution close to the physical limit and demonstrates the following main characteristics: equilibrium orbit radius ρ 0 = 80 mm, instrumental energy resolution 0.6 % at solid angle 1 % of 4π steradian, area of non-equipotential source ∼ 80 mm 2 , registration by position-sensitive detector of ∼ 10 % of the energy interval. Highly-effective portable beta spectrometer assures obtaining Moessbauer data with depth resolution close to physical limit of the DS EMS method. So in measurements at conversion and Auger electrons with energies of about units of keV and above, the achieved

  13. Tritium power source for long-lived sensors

    Science.gov (United States)

    Litz, M. S.; Katsis, D. C.; Russo, J. A.; Carroll, J. J.

    2014-06-01

    A tritium-based indirect converting photovoltaic (PV) power source has been designed and prototyped as a long-lived (~15 years) power source for sensor networks. Tritium is a biologically benign beta emitter and low-cost isotope acquired from commercial vendors for this purpose. The power source combines tritium encapsulated with a radioluminescent phosphor coupled to a commercial PV cell. The tritium, phosphor, and PV components are packaged inside a BA5590-style military-model enclosure. The package has been approved by the nuclear regulatory commission (NRC) for use by DOD. The power source is designed to produce 100μW electrical power for an unattended radiation sensor (scintillator and avalanche photodiode) that can detect a 20 μCi source of 137Cs at three meters. This beta emitting indirect photon conversion design is presented as step towards the development of practical, logistically acceptable, lowcost long-lived compact power sources for unattended sensor applications in battlefield awareness and environmental detection.

  14. $\\beta$-decay studies using total absorption techniques some recent results

    CERN Document Server

    Algora, A; García-Borge, M J; Cano-Ott, D; Collatz, R; Courtin, S; Dessagne, P; Fraile-Prieto, L M; Gadea, A; Gelletly, W; Hellström, M; Janas, Z; Jungclaus, A; Karny, M; Kirchner, R; Maréchal, F; Miehé, C; Moroz, F; Nacher, E; Poirier, E; Roeckl, E; Rubio, B; Rykaczewski, K; Scornet, G L; Taín, J L; Tengblad, O; Wittmann, V

    2004-01-01

    $\\beta$-decay experiments, are a primary source of information for nuclear structure studies and at the same time complementary to in-beam investigations far from stability. Although both types of experiment are mainly based on $\\gamma$-ray spectroscopy, they face different experimental problems. The so-called $\\textit{Pandemonium effect}$ is a critical problem in $\\beta$-decay. In this contribution we will present a solution to this problem using total absorption spectroscopy methods. We will also present some examples of experiments carried out with the total absorption spectrometers TAS at GSI and Lucrecia recently installed at CERN. (25 refs).

  15. Beta-decay studies using total absorption techniques: some recent results

    Energy Technology Data Exchange (ETDEWEB)

    Algora, A.; Rubio, B.; Nacher, E.; Cano O, D.; Tain, J.L.; Gadea, A. [lnstituto de Fisica Corpuscular, Apartado Oficial 22085, 46071 Valencia (Spain); Batist, L.; Moroz, F.; Wittmann, V. [St. Petersburg Nuclear Physics Institute, RU-188-350 Gatchina, (Russian Federation); Borge, M.J.G.; Jungclaus, A.; Tengblad, O. [Instituto Estructura de la Materia, E-28006 Madrid (Spain); Collatz, R.; Hellstrom, M.; Kirchner, R.; Roeckl, E. [Gesellschaft fur Schwerionenforschung, D-64291 Darmstadt (Germany); Courtin, H.; Dessagne, Ph.; Miehe, C.; Marechal, F.; Poirier, E. [lnstitut de Recherches Subatomiques, IN2P3-CNRS, F-67037 Strassbourg Cedex 2 (France); Fraile, L.M. [ISOLDE, Division EP, CERN, CH-1211 Geneva (Switzerland); Gelletly, W. [University of Surrey, Guildford GU2 7XH (United Kingdom); Janas, Z.; Karny, M.; Rykaczewski, K. [University of Warsaw, PL-00-681, Warsaw (Poland); Le Scornet, G. [CSNSM, 91405 Orsay (France)

    2004-12-01

    Beta-decay experiments are a primary source of information for nuclear structure studies and at the same time complementary to in-beam investigations far from stability. Although both types of experiment are mainly based on {gamma} ray spectroscopy, they face different experimental problems. The so called Pandemonium effect [1] is a critical problem in {beta}-decay. In this contribution we will present a solution to this problem using total absorption spectroscopy methods. We will also present some examples of experiments carried out with the total absorption spectrometers TAS at GSI and Lucrecia recently installed at CERN. (Author) 25 refs., 4 figs.

  16. Beta attenuation transmission system (BATS)

    Energy Technology Data Exchange (ETDEWEB)

    Hagan, R.C.; Fullbright, H.J.

    1977-01-01

    The beta attenuation transmission system (BATS) is an automated radiation gauge designed for quantitative measurement of component thickness in explosive detonators. The BATS was designed and built by Group M-1, the Nondestructive Testing Group, of the Los Alamos Scientific Laboratory to measure the areal thickness, in mg/cm/sup 2/, of a cylinder of high explosive (HE) enclosed within a plastic holder. The problem is to determine the density of the HE. A /sup 90/Sr source is collimated by a 0.25 x 1.59-mm slit, and the transmitted beta-particle flux is detected by a plastic scintillator, coupled to a photomultiplier tube. The detonator is transported through the radiation beam by a leadscrew, ballnut, stepping-motor combination. Continuous analog position data are available, derived from the output from a linear-actuated potentiometer attached to the scanner. A linear electrometer amplifies the detected signal, which is then integrated for a preselected time, to obtain the desired statistical accuracy. A microprocessor (..mu..P) is used to control the scanner position and to make the data readings at the assigned positions. The data are stored, and, at the completion of the scan, are processed into the desired format. The final answer is displayed to the operator or output to a peripheral device for permanent record. The characteristics of the radiation source, the collimator, the signal detection and conditioning, and the final results are described in detail. The scanner and the microprocessor control system are briefly outlined.

  17. Beta attenuation transmission system (BATS)

    International Nuclear Information System (INIS)

    Hagan, R.C.; Fullbright, H.J.

    1977-01-01

    The beta attenuation transmission system (BATS) is an automated radiation gauge designed for quantitative measurement of component thickness in explosive detonators. The BATS was designed and built by Group M-1, the Nondestructive Testing Group, of the Los Alamos Scientific Laboratory to measure the areal thickness, in mg/cm 2 , of a cylinder of high explosive (HE) enclosed within a plastic holder. The problem is to determine the density of the HE. A 90 Sr source is collimated by a 0.25 x 1.59-mm slit, and the transmitted beta-particle flux is detected by a plastic scintillator, coupled to a photomultiplier tube. The detonator is transported through the radiation beam by a leadscrew, ballnut, stepping-motor combination. Continuous analog position data are available, derived from the output from a linear-actuated potentiometer attached to the scanner. A linear electrometer amplifies the detected signal, which is then integrated for a preselected time, to obtain the desired statistical accuracy. A microprocessor (μP) is used to control the scanner position and to make the data readings at the assigned positions. The data are stored, and, at the completion of the scan, are processed into the desired format. The final answer is displayed to the operator or output to a peripheral device for permanent record. The characteristics of the radiation source, the collimator, the signal detection and conditioning, and the final results are described in detail. The scanner and the microprocessor control system are briefly outlined

  18. Effects of beta/gamma radiation on nuclear waste glasses

    Energy Technology Data Exchange (ETDEWEB)

    Weber, W.J. [Pacific Northwest National Lab., Richland, WA (United States)

    1997-07-01

    A key challenge in the disposal of high-level nuclear waste (HLW) in glass waste forms is the development of models of long-term performance based on sound scientific understanding of relevant phenomena. Beta decay of fission products is one source of radiation that can impact the performance of HLW glasses through the interactions of the emitted {beta}-particles and g-rays with the atoms in the glass by ionization processes. Fused silica, alkali silicate glasses, alkali borosilicate glasses, and nuclear waste glasses are all susceptible to radiation effects from ionization. In simple glasses, defects (e.g., non-bridging oxygen and interstitial molecular oxygen) are observed experimentally. In more complex glasses, including nuclear waste glasses, similar defects are expected, and changes in microstructure, such as the formation of bubbles, have been reported. The current state of knowledge regarding the effects of {beta}/{gamma} radiation on the properties and microstructure of nuclear waste glasses are reviewed. (author)

  19. Optimization of Plastic Scintillator Thicknesses for Online Beta Detection in Mixed Fields

    Energy Technology Data Exchange (ETDEWEB)

    Pourtangestani, K.; Machrafi, R. [University of Ontario Institute of Technology, Oshawa, ON (Canada)

    2013-07-15

    For efficient beta detection in a mixed beta-gamma field, Monte Carlo simulation models have been developed to optimize the thickness of a plastic scintillator used in whole body monitor. The simulation has been performed using MCNP/X code and different thicknesses of plastic scintillators ranging from 150 to 600 {mu}m have been used. The relationship between the thickness of the scintillator and the efficiency of the detector has been analysed. For 150 {mu}m thickness, an experimental investigation has been conducted with different beta sources at different positions on the scintillator and the counting efficiency of the unit has been measured. Evaluated data along with experimental ones have been discussed. A thickness of 300 {mu}m to 500 {mu}m has been found to be an optimum thickness for better beta detection efficiency in the presence of low energy gamma ray. (author)

  20. Rapid synthesis of beta zeolites

    Science.gov (United States)

    Fan, Wei; Chang, Chun -Chih; Dornath, Paul; Wang, Zhuopeng

    2015-08-18

    The invention provides methods for rapidly synthesizing heteroatom containing zeolites including Sn-Beta, Si-Beta, Ti-Beta, Zr-Beta and Fe-Beta. The methods for synthesizing heteroatom zeolites include using well-crystalline zeolite crystals as seeds and using a fluoride-free, caustic medium in a seeded dry-gel conversion method. The Beta zeolite catalysts made by the methods of the invention catalyze both isomerization and dehydration reactions.

  1. Active-site-directed inactivation of Aspergillus oryzae beta-galactosidase with beta-D-galactopyranosylmethyl-p-nitrophenyltriazene.

    Science.gov (United States)

    Mega, T; Nishijima, T; Ikenaka, T

    1990-04-01

    beta-D-Galactopyranosylmethyl-p-nitrophenyltriazene (beta-GalMNT), a specific inhibitor of beta-galactosidase, was isolated as crystals by HPLC and its chemical and physicochemical characteristics were examined. Aspergillus oryzae beta-galactosidase was inactivated by the compound. We studied the inhibition mechanism in detail. The inhibitor was hydrolyzed by the enzyme to p-nitroaniline and an active intermediate (beta-galactopyranosylmethyl carbonium or beta-galactopyranosylmethyldiazonium), which inactivated the enzyme. The efficiency of inactivation of the enzyme (the ratio of moles of inactivated enzyme to moles of beta-GalMNT hydrolyzed by the enzyme) was 3%; the efficiency of Escherichia coli beta-galactosidase was 49%. In spite of the low efficiency, the rate of inactivation of A. oryzae enzyme was not very different from that of the E. coli enzyme, because the former hydrolyzed beta-GalMNT faster than the latter did. A. oryzae beta-galactosidase was also inactivated by p-chlorophenyl, p-tolyl, and m-nitrophenyl derivatives of beta-galactopyranosylmethyltriazene. However, E. coli beta-galactosidase was not inactivated by these triazene derivatives. The results showed that the inactivation of A. oryzae and E. coli beta-galactosidases by beta-GalMNT was an enzyme-activated and active-site-directed irreversible inactivation. The possibility of inactivation by intermediates produced nonenzymatically was ruled out for E. coli, but not for the A. oryzae enzyme.

  2. Radiolytical oxidation of gaseous iodine by beta radiation

    International Nuclear Information System (INIS)

    Kaerkelae, Teemu; Auvinen, Ari; Kekki, Tommi; Kotiluoto, Petri; Lyyraenen, Jussi; Jokiniemi, Jorma

    2015-01-01

    Iodine is one of the most radiotoxic fission product released from fuel during a severe nuclear power plant accident. Within the containment building, iodine compounds can react e.g. on the painted surfaces and form gaseous organic iodides. In this study, it was found out that gaseous methyl iodide (CH 3 I) is oxidised when exposed to beta radiation in an oxygen containing atmosphere. As a result, nucleation of aerosol particles takes place and the formation of iodine oxide particles is suggested. These particles are highly hygroscopic. They take up water from the air humidity and iodine oxides dissolve within the droplets. In order to mitigate the possible source term, it is of interest to understand the effect of beta radiation on the speciation of iodine.

  3. Radiolytical oxidation of gaseous iodine by beta radiation

    Energy Technology Data Exchange (ETDEWEB)

    Kaerkelae, Teemu; Auvinen, Ari; Kekki, Tommi; Kotiluoto, Petri; Lyyraenen, Jussi [VTT Technical Research Centre of Finland, Espoo (Finland); Jokiniemi, Jorma [VTT Technical Research Centre of Finland, Espoo (Finland); Eastern Finland Univ., Kuopio (Finland)

    2015-07-01

    Iodine is one of the most radiotoxic fission product released from fuel during a severe nuclear power plant accident. Within the containment building, iodine compounds can react e.g. on the painted surfaces and form gaseous organic iodides. In this study, it was found out that gaseous methyl iodide (CH{sub 3}I) is oxidised when exposed to beta radiation in an oxygen containing atmosphere. As a result, nucleation of aerosol particles takes place and the formation of iodine oxide particles is suggested. These particles are highly hygroscopic. They take up water from the air humidity and iodine oxides dissolve within the droplets. In order to mitigate the possible source term, it is of interest to understand the effect of beta radiation on the speciation of iodine.

  4. The potential contribution of bread buns fortified with beta-carotene-rich sweet potato in Central Mozambique.

    Science.gov (United States)

    Low, Jan W; van Jaarsveld, Paul J

    2008-06-01

    Orange-fleshed sweet potato is an efficacious source of vitamin A. Substituting wheat flour with orange-fleshed sweet potato in processed products could reduce foreign exchange outlays, create new markets for producers, and result in increased vitamin A consumption among consumers provided there is adequate retention of beta-carotene during processing. To explore whether substituting 38% of wheat flour (by weight) in bread buns ("golden bread") with boiled and mashed orange-fleshed sweet potato from fresh roots or rehydrated chips would produce economically viable beta-carotene-rich products acceptable to Mozambican rural consumers. Modified local recipes maximized sweet potato content within the limits of consumer acceptability. Sensitivity analysis determined parameters underlying economic viability. Two samples each of buns from five varieties of orange-fleshed sweet potato were analyzed for beta-carotene content. Processed products with at least 15 microg/g product of trans-beta-carotene were considered good sources of vitamin A. Golden bread made from fresh roots of medium-intensity orange-fleshed sweet potato varieties met the good source criterion, but bread from lighter-intensity sweet potato varieties did not. Bread from rehydrated dried chips was not economically viable. Consumers strongly preferred golden bread over pure wheat flour bread because of its heavier texture and attractive appearance. The ratio of the price of wheat flour to that of raw sweet potato root varied from 3.1 to 3.5 among the bakers, whose increase in profit margins ranged from 54% to 92%. Golden bread is a good source of beta-carotene and is economically viable when the price ratio of wheat flour to raw orange-fleshed sweet potato root is at least 1.5. Widespread adoption during sweet potato harvesting periods is feasible; year-round availability requires storage.

  5. Maternal plasma concentrations of beta-lipotrophin, beta-endorphin and gamma-lipotrophin throughout pregnancy.

    Science.gov (United States)

    Browning, A J; Butt, W R; Lynch, S S; Shakespear, R A

    1983-12-01

    Plasma beta-LPH, beta-EP and gamma-LPH concentrations were measured by radioimmunoassay in 10 pregnant women from 12 weeks gestation until term and in nine women in the early follicular phase of the cycle. There was a progressive and significant rise in the concentration of all three peptides throughout pregnancy and by 32 weeks the concentrations of beta-LPH and beta-EP were greater than the corresponding concentrations in the follicular phase: gamma-LPH was greater than in the follicular phase by the end of pregnancy in those women who were delivered after 40 weeks. The ratio of beta-LPH to gamma-LPH did not change significantly throughout pregnancy, but there was a progressive fall in the beta-LPH/beta-EP ratio. The possible presence of a 'big LPH' to explain this finding is discussed.

  6. Some methods for calibration and beta radiation dosimetry

    International Nuclear Information System (INIS)

    Caldas, Linda V. Ehlin

    1980-01-01

    The calibration of beta radiation was studied from the point of view of primary and secondary standardization, using extrapolation chambers and examining several effects. The properties of a commercial ionization chamber were investigated, and the possibility of its use in calibration and dosimetry of 90 Sr- 90 Y beta radiation was demonstrated . A secondary standard calibration facility was developed and the results obtained with this facility were compared with those obtained from a primary system directly or indirectly. Nearly energy independent response was obtained in.the range 60 keV to 0,8 MeV with this secondary standard. Two solid state techniques namely thermoluminescence (TL) and thermally stimulated exoelectron emission (TSEE) were also used for beta dosimetry. Various characteristics like reproducibility, response with dose,energy dependence, etc. were studied for the materials: LiF, CaF 2 ,Li 2 B 4 O 7 , Be O, CaSO 4 and Al 2 O 3 . TL detectors of thickness 0,9 mm underestimate the dose 60 μm thick CaSO 4 :Tm embedded on a thin aluminium plate gave energy independent response behind skin layers of 7 mg/cm 2 . Mixed field of beta, X and gamma radiation was analysed using this detector. Quartz based Be O and graphite based alpha beta-Al 2 O 3 were found to be good beta radiation detectors when the TSEE technique is used. Energy independent CaSO 4 :Tm TL dosimeters were used in international comparison for dose measurements and the results obtained were in agreement with the actual given doses within 10%. The TL detectors were also used for dose rate measurements from glazed painted tiles used in construction industry and a 85 Kr source used in textile and metal industries. Results obtained in the later case were Q compared with those using the secondary standard facility. (author)

  7. Optimized formation of detergent micelles of beta-carotene and retinal production using recombinant human beta,beta-carotene 15,15'-monooxygenase.

    Science.gov (United States)

    Kim, Nam-Hee; Kim, Yeong-Su; Kim, Hye-Jung; Oh, Deok-Kun

    2008-01-01

    The formation of beta-carotene detergent micelles and their conversion into retinal by recombinant human beta,beta-carotene 15,15'-monooxygenase was optimized under aqueous conditions. Toluene was the most hydrophobic among the organic solvents tested; thus, it was used to dissolve beta-carotene, which is a hydrophobic compound. Tween 80 was selected as the detergent because it supported the highest level of retinal production among all of the detergents tested. The maximum production of retinal was achieved in detergent micelles containing 200 mg/L of beta-carotene and 2.4% (w/v) Tween 80. Under these conditions, the recombinant enzyme produced 97 mg/L of retinal after 16 h with a conversion yield of 48.5% (w/w). The amount of retinal produced, which is the highest ever reported, is a result of the ability of our system to dissolve large amounts of beta-carotene.

  8. Beta cell adaptation in pregnancy

    DEFF Research Database (Denmark)

    Nielsen, Jens Høiriis

    2016-01-01

    Pregnancy is associated with a compensatory increase in beta cell mass. It is well established that somatolactogenic hormones contribute to the expansion both indirectly by their insulin antagonistic effects and directly by their mitogenic effects on the beta cells via receptors for prolactin...... and growth hormone expressed in rodent beta cells. However, the beta cell expansion in human pregnancy seems to occur by neogenesis of beta cells from putative progenitor cells rather than by proliferation of existing beta cells. Claes Hellerström has pioneered the research on beta cell growth for decades...... in the expansion of the beta cell mass in human pregnancy, and the relative roles of endocrine factors and nutrients....

  9. Beta spectrometry

    International Nuclear Information System (INIS)

    Dryak, P.; Zderadicka, J.; Plch, J.; Kokta, L.; Novotna, P.

    1977-01-01

    For the purpose of beta spectrometry, a semiconductor spectrometer with one Si(Li) detector cooled with liquid nitrogen was designed. Geometrical detection efficiency is about 10% 4 sr. The achieved resolution for 624 keV conversion electrons of sup(137m)Ba is 2.6 keV (FWHM). A program was written in the FORTRAN language for the correction of the deformation of the measured spectra by backscattering in the analysis of continuous beta spectra. The method permits the determination of the maximum energy of the beta spectrum with an accuracy of +-5 keV. (author)

  10. DMPD: Immunoreceptor-like signaling by beta 2 and beta 3 integrins. [Dynamic Macrophage Pathway CSML Database

    Lifescience Database Archive (English)

    Full Text Available 17913496 Immunoreceptor-like signaling by beta 2 and beta 3 integrins. Jakus Z, Fod...) Show Immunoreceptor-like signaling by beta 2 and beta 3 integrins. PubmedID 17913496 Title Immunoreceptor-...like signaling by beta 2 and beta 3 integrins. Authors Jakus Z, Fodor S, Abram CL

  11. Identification of active anti-inflammatory principles of beta- beta ...

    African Journals Online (AJOL)

    chromatography. Components of the extracts were identified by thin layer chromatography (TLC) scanner and UV-visible spectroscopy, using scopoletin as standard. Results: ... basic coumarin skeleton ring structure reduce ... Figure 2: Thin-layer chromatogram: (1) Ethanol extract; (2) Dichloromethane fraction; (3) Beta-beta.

  12. Dimers of beta 2-glycoprotein I mimic the in vitro effects of beta 2-glycoprotein I-anti-beta 2-glycoprotein I antibody complexes

    NARCIS (Netherlands)

    Lutters, B. C.; Meijers, J. C.; Derksen, R. H.; Arnout, J.; de Groot, P. G.

    2001-01-01

    Anti-beta(2)-glycoprotein I antibodies are thought to cause lupus anticoagulant activity by forming bivalent complexes with beta(2)-glycoprotein I (beta(2)GPI). To test this hypothesis, chimeric fusion proteins were constructed of the dimerization domain (apple 4) of factor XI and beta(2)GPI. Both a

  13. Exercise- and cold-induced changes in plasma beta-endorphin and beta-lipotropin in men and women.

    Science.gov (United States)

    Viswanathan, M; Van Dijk, J P; Graham, T E; Bonen, A; George, J C

    1987-02-01

    The plasma beta-endorphin (beta-EP) and beta-lipotropin (beta-LPH) response of men, eumenorrheic women, and amenorrheic women (n = 6) to 1 h of rest or to a bicycle ergometer test [20 min at 30% maximum O2 uptake (VO2max), 20 min at 60% VO2max, and at 90% VO2max to exhaustion] was studied in both normal (22 degrees C) and cold (5 degrees C) environments. beta-EP and beta-LPH was measured by radioimmunoassay in venous samples collected every 20 min during rest or after each exercise bout. Exhaustive exercise at ambient temperature (Ta) 22 degrees C induced significant increases in plasma beta-EP and beta-LPH in all subjects as did work at 60% VO2max in amenorrheic and eumenorrheic women. During work at Ta 5 degrees C, the relative increase in beta-EP and beta-LPH was suppressed in eumenorrheic women and completely prevented in amenorrheic women. Although significant lowering of beta-EP and beta-LPH was observed in men and eumenorrheic women during rest at 5 degrees C, amenorrheic women maintained precold exposure levels. These findings suggest that plasma beta-EP and beta-LPH may reflect a thermoregulatory response to heat load. There appears to be a sexual dimorphism in exercise- and cold-induced release of beta-EP and beta-LPH and amenorrhea may be accompanied by alterations in these responses.

  14. Beta-decay of {sup 103}In: evidence for the Gamow-Teller resonance near {sup 100}Sn

    Energy Technology Data Exchange (ETDEWEB)

    Karny, M. [Warsaw Univ. (Poland). Inst. of Experimental Physics; Batist, L.; Brown, B.A. [and others

    1998-04-01

    The {beta} decay of the neutron-deficient isotope {sup 103}In was investigated by using total absorption {gamma}-ray spectrometry on mass-separated sources. The measurement reveals a high-lying resonance of the {beta}-decay strength in striking disagreement with high-resolution {gamma}-ray data. The result is discussed in comparison with shell-model predictions. (orig.)

  15. A 4{pi} Anticoincidence Arrangement for Measurements of Beta-Ray Emitting Isotopes; Montage a Anticoiencidence 4{pi} pour la Mesure des Radioisotopes Emetteurs Beta; 4{pi} sistema schetchikov antisovpadenij dlya izmerenij beta-izluchayushchikh izotopov; Aparato de Recuento 4{pi} en Anticoincidencia para Medir Emisores Beta

    Energy Technology Data Exchange (ETDEWEB)

    Srdoc, D. [Institute ' ' Ruder Boskovic' ' , Zagreb, Yugoslavia (Croatia)

    1965-10-15

    A 4{pi} anticoincidence, low-background counting system consisting of two specially designed parallel plate counters and a bridge anticoincidence circuit is described. Each counter is of a flat, mica window ''pancake'' type. The diameter of the counters is much larger than the gap between the plates. Good counting properties are obtained in spite of the unusual counter geometry, owing to the flexibility of the counter shape design when a neon-halogen mixture is used. The counters are so arranged that both windows face the sample, leaving a narrow slit for the sample holder. The sample is spread on a thin metalized plastic film. The pulses from both counters due to beta-particles coming from the sample are recorded, giving a 4{pi} counting geometry. The pulses due to cosmic particles triggering both counters simultaneously cancel out in a simple bridge anticoincidence arrangement, thus eliminating the need for an electronic circuit. Furthermore, the parallel plate counters used here for beta-particle counting possess a markedly reduced sensitivity to gamma-rays near the threshold voltage, resulting in a further lowering of the background. Sources of beta-particles of higher energies, as well as gamma-ray sources, can also be measured by the described system, because in the proposed geometry there is no possibility of triggering both counters simultaneously, as is the case with the conventional guard-counter arrangements. (author) [French] Le memoire decrit un ensemble de mesure a anticolhcidence 4{pi}, ayant un faible bruit de fond, compose de deux compteurs speciaux a plateaux paralleles relies par un pont d'anticofncidence. Ces deux compteurs sont de type circulaire plat a fenetre de mica. Le diametre du compteur est tres superieur a l'espace entre les plaques. Malgre sa geometrie inusitee, l'appareil a des proprietes de comptage satisfaisantes en raison de la souplesse que lui conferent ses caracteristiques lorsqu'on utilise un melange halogene-neon. Les

  16. beta-Thalassemia present in cis to a new beta-chain structural variant, Hb Vicksburg [beta 75 (E19)Leu leads to 0].

    Science.gov (United States)

    Adams, J G; Steinberg, M H; Newman, M V; Morrison, W T; Benz, E J; Iyer, R

    1981-01-01

    Hemoglobin Vicksburg was discovered in a 6-year-old Black boy who had been anemic since infancy. Examination of his hemolysate revealed 87.5% Hb F, 2.4% Hb A2, and 7.6% Hb Vicksburg, which had the electrophoretic and chromatographic properties of Hb A. Structural analysis of Hb Vicksburg demonstrated a deletion of leucine at beta 75(E19), a new variant. Hb Vicksburg was neither unstable nor subject to posttranslational degradation. The alpha/non-alpha biosynthetic ratio was 2.6. Because the proband appeared to be a mixed heterozygote for Hb Vicksburg and beta 0-thalassemia, Hb Vicksburg should have comprised the major portion of the hemolysate. Thus, Hb Vicksburg was synthesized at a rate considerably lower than would be expected on the basis of gene dosage. There was no reason to suspect abnormal translation of beta Vicksburg mRNA; in individuals with Hb St. Antoine (beta 74 and beta 75 deleted), the abnormal hemoglobin comprised 25% of the hemolysate in the simple heterozygote yet was unstable. Deletion of beta 75, therefore, would not in itself appear to lead to diminished synthesis. There was a profound deficit of beta Vicksburg mRNA when measured by liquid hybridization analysis with beta cDNA. The most plausible explanation for the low output of Hb Vicksburg is that a mutation for beta +-thalassemia is present in cis to the structural mutation.

  17. Clusters of conserved beta cell marker genes for assessment of beta cell phenotype

    DEFF Research Database (Denmark)

    Martens, Geert A; Jiang, Lei; Hellemans, Karine H

    2011-01-01

    The aim of this study was to establish a gene expression blueprint of pancreatic beta cells conserved from rodents to humans and to evaluate its applicability to assess shifts in the beta cell differentiated state. Genome-wide mRNA expression profiles of isolated beta cells were compared to those...... of a large panel of other tissue and cell types, and transcripts with beta cell-abundant and -selective expression were identified. Iteration of this analysis in mouse, rat and human tissues generated a panel of conserved beta cell biomarkers. This panel was then used to compare isolated versus laser capture...

  18. beta-Carotene in breast milk and serum is increased after a single beta-carotene dose.

    Science.gov (United States)

    Canfield, L M; Giuliano, A R; Neilson, E M; Yap, H H; Graver, E J; Cui, H A; Blashill, B M

    1997-07-01

    Normal lactating mothers were administered a single dose of 60 or 210 mg beta-carotene and changes in serum and milk retinol, alpha-tocopherol, and carotenoids were monitored for 8 d. Average serum beta-carotene concentrations increased 4.1- and 4.0-fold after the 60- and 210-mg doses, respectively. Milk beta-carotene concentrations increased 4.1- and 3.0-fold after the 60- and 210-mg doses, respectively. Maximum serum concentrations were reached 24 h after both supplements, although concentrations of milk beta-carotene continued to rise for 2-3 d. After 8 d, both serum and milk beta-carotene continued to rise for 2-3 d. After 8 d, both serum and milk beta-carotene concentrations remained about twofold higher than baseline concentrations. Increases in serum or milk beta-carotene concentrations were not dose-dependent. Initial serum and milk concentrations of beta-carotene predicted increases after supplementation, and increases in serum beta-carotene concentrations predicted those in milk. Concentrations of milk carotenoids were less than one-tenth their respective concentrations in serum. Lutein, beta-cryptoxanthin, lycopene, alpha-carotene, retinol, and alpha-tocopherol concentrations in serum or milk did not change significantly after beta-carotene supplementation. Retinol esters account for most of the retinol equivalents in the milk of well-nourished mothers. Initial and maximum concentrations of beta-carotene in serum and milk were strongly correlated for individual mothers. Collectively, the data showed that a single 60-mg supplement of beta-carotene sustained elevated beta-carotene concentrations in serum and milk for > 1 wk in normal mothers but did not affect concentrations of other major carotenoids, retinol, or alpha-tocopherol.

  19. Neutrinoless double beta decay in type I+II seesaw models

    Energy Technology Data Exchange (ETDEWEB)

    Borah, Debasish [Department of Physics, Tezpur University,Tezpur-784028 (India); Dasgupta, Arnab [Institute of Physics, Sachivalaya Marg,Bhubaneshwar-751005 (India)

    2015-11-30

    We study neutrinoless double beta decay in left-right symmetric extension of the standard model with type I and type II seesaw origin of neutrino masses. Due to the enhanced gauge symmetry as well as extended scalar sector, there are several new physics sources of neutrinoless double beta decay in this model. Ignoring the left-right gauge boson mixing and heavy-light neutrino mixing, we first compute the contributions to neutrinoless double beta decay for type I and type II dominant seesaw separately and compare with the standard light neutrino contributions. We then repeat the exercise by considering the presence of both type I and type II seesaw, having non-negligible contributions to light neutrino masses and show the difference in results from individual seesaw cases. Assuming the new gauge bosons and scalars to be around a TeV, we constrain different parameters of the model including both heavy and light neutrino masses from the requirement of keeping the new physics contribution to neutrinoless double beta decay amplitude below the upper limit set by the GERDA experiment and also satisfying bounds from lepton flavor violation, cosmology and colliders.

  20. Beta Thalassemia (For Parents)

    Science.gov (United States)

    ... Safe Videos for Educators Search English Español Beta Thalassemia KidsHealth / For Parents / Beta Thalassemia What's in this ... Symptoms Diagnosis Treatment Print en español Beta talasemia Thalassemias Thalassemias are a group of blood disorders that ...

  1. Ser2 is the autophosphorylation site in the beta subunit from bicistronically expressed human casein kinase-2 and from native rat liver casein kinase-2 beta

    DEFF Research Database (Denmark)

    Boldyreff, B; James, P; Staudenmann, W

    1993-01-01

    Human casein kinase-2 (CK-2) subunits alpha and beta were bicistronically expressed in bacteria. The recombinant holoenzyme shared all investigated properties with the native CK-2 from mammalian sources (rat liver, Krebs II mouse ascites tumour cells). Contrary to recombinant human CK-2 produced...

  2. High-precision thickness measurements using beta backscatter

    International Nuclear Information System (INIS)

    Heckman, R.V.

    1978-11-01

    A two-axis, automated fixture for use with a high-intensity Pm-147 source and a photomultiplier-scintillation beta-backscatter probe for making thickness measurements has been designed and built. A custom interface was built to connect the system to a minicomputer, and software was written to position the tables, control the probe, and make the measurements. Measurements can be made in less time with much greater precision than by the method previously used

  3. Comparison of iodine-123 labelled 2{beta}-carbomethoxy-3{beta}-(4-iodophenyl)tropane and 2{beta}-carbomethoxy-3{beta}-(4-iodophenyl)-N-(3-fluoropropyl)nortropane for imaging of the dopamine transporter in the living human brain

    Energy Technology Data Exchange (ETDEWEB)

    Kuikka, J.T. [Dept. of Clinical Physiology, Kuopio Univ. Hospital (Finland); Bergstroem, K.A. [Dept. of Clinical Physiology, Kuopio Univ. Hospital (Finland); Ahonen, A. [Dept. of Clinical Chemistry, Oulu Univ. Central Hospital (Finland); Hiltunen, J. [MAP Medical Technologies Oy, Tikkakoski (Finland); Haukka, J. [MAP Medical Technologies Oy, Tikkakoski (Finland); Laensimies, E. [Dept. of Clinical Physiology, Kuopio Univ. Hospital (Finland); Wang Shaoyin [Research Biochemicals International (RBI), Natick, MA (United States); Neumeyer, J.L. [Research Biochemicals International (RBI), Natick, MA (United States)

    1995-04-01

    Several cocaine congeners are of potential for imaging the dopamine transporter (DAT). Previous studies have shown that iodine-123 labelled 2{beta}-carbomethoxy-3{beta}-(4-iodophenyl)tropane ([{sup 123}I]{beta}-CIT) is a promising radiotracer for imaging the serotonin (5-HT) and dopamine (DA) transporters in the living human brain with single-photon emission tomography (SPET). [{sup 123}I]{beta}-CIT was found to be not very practical for 1-day DAT imaging protocols since peak DAT uptake occurs later than 8 h. Here we report a pilot comparison of [{sup 123}I]{beta}-CIT and 2{beta}-carbomethoxy-3{beta}-(4-iodophenyl)-N-(3-fluoropropyl)nortropane ([{sup 123}I]{beta}-CIT-FP), using SPET imaging in four healthy male subjects. Peak uptake of [{sup 123}I]{beta}-CIT-FP into the basal ganglia occurred earlier (3-4 h after injection of tracer) than that of [{sup 123}I]{beta}-CIT (>8 h). However, the specific DAT binding of [{sup 123}I]{beta}-CIT-FP in the basal ganglia was somewhat less (0.813{+-}0.047) than that of [{sup 123}I]{beta}-CIT (0.922{+-}0.004). Imaging quality is excellent with both tracers and they are potentially of value for brain imaging in various neuropsychiatric disorders. (orig.)

  4. Systematic Risk on Istanbul Stock Exchange: Traditional Beta Coefficient Versus Downside Beta Coefficient

    Directory of Open Access Journals (Sweden)

    Gülfen TUNA

    2013-03-01

    Full Text Available The aim of this study is to test the validity of Downside Capital Asset Pricing Model (D-CAPM on the ISE. At the same time, the explanatory power of CAPM's traditional beta and D-CAPM's downside beta on the changes in the average return values are examined comparatively. In this context, the monthly data for seventy three stocks that are continuously traded on the ISE for the period 1991-2009 is used. Regression analysis is applied in this study. The research results have shown that D-CAPM is valid on the ISE. In addition, it is obtained that the power of downside beta coefficient is higher than traditional beta coefficient on explaining the return changes. Therefore, it can be said that the downside beta is superior to traditional beta in the ISE for chosen period.

  5. Purification and characterisation of an extracellular fructan beta-fructosidase from a Lactobacillus pentosus strain isolated from fermented fish

    DEFF Research Database (Denmark)

    Paludan-Müller, Christine; Gram, Lone; Rattray, F.P.

    2002-01-01

    Lactobacillus pentosus B235, which was isolated as part of the dominant microflora from a garlic containing fermented fish product, was grown in a chemically defined medium With inulin as the sole carbohydrate source. An extracellular fructan beta- fructosidase was purified to homogeneity from...... fructan), but also hydrolysed garlic extract, (a beta(2-->1)-linked fructan with beta(2-->6)-linked fructosyl sidechains), 1,1,1-kestose, 1,1-kestose, 1-kestose, inulin (beta(2-->1)-linked fructans) and Sucrose at 60, 45, 39, 12, 9 and 3%, respectively, of the activity observed for levan. Melezitose...

  6. Integrins beta 5, beta 3 and alpha v are apically distributed in endometrial epithelium.

    Science.gov (United States)

    Aplin, J D; Spanswick, C; Behzad, F; Kimber, S J; Vićovac, L

    1996-07-01

    Several adhesion molecules have been shown to occur at the surface of endometrial cells. One of these is the integrin alpha v subunit which associates with various beta chains including beta 5. We demonstrate the presence of integrin beta 5 polypeptide in human endometrial epithelial cells throughout the menstrual cycle using immunocytochemistry with monospecific antibodies, and at the mRNA level by thermal amplification from endometrial cDNA. Integrin beta 5 is also found in a population of bone marrow-derived cells. A notable feature of the distribution of the beta 5 subunit in the glandular and luminal epithelium is its apical localization, which may suggest an involvement in implantation. However, no evidence was found for regulated expression of epithelial beta 5. In mouse, the beta 5 subunit is found at both the apical and basal surface of epithelial cells and expression is essentially oestrous cycle-independent. Comparisons are made in both species with the distribution of the alpha v and beta 3 subunits which also localize to the apical epithelium.

  7. Origin of fecal contamination in waters from contrasted areas: Stanols as Microbial Source Tracking markers

    OpenAIRE

    Derrien, M.; Jarde, E.; Gruau, G.; Pourcher, A. M.; Gourmelon, Michele; Jadas-hecart, Alain; Wickmann, A. C. Pierson

    2012-01-01

    Improving the microbiological quality of coastal and river waters relies on the development of reliable markers that are capable of determining sources of fecal pollution. Recently, a principal component analysis (PCA) method based on six stanol compounds (i.e. 5 beta-cholestan-3 beta-ol (coprostanol), 5 beta-cholestan-3 alpha-ol (epicoprostanol), 24-methyl-5 alpha-cholestan-3 beta-ol (campestanol), 24-ethyl-5 alpha-cholestan-3 beta-ol (sitostanol), 24-ethyl-5 beta-cholestan-3 beta-ol (24-eth...

  8. Cryogenic micro-calorimeters for beta spectroscopy: A status report

    International Nuclear Information System (INIS)

    Lowry, M.M.; Deptuck, D.; Girit, I.C.; Calaprice, F.P.

    1992-01-01

    Status of efforts to develop a cryogenic micro-calorimeter as a beta spectrometer for 17 keV neutrino searches is given. Experimental requirements are derived. Using NTD germanium thermometry, adequate detector performance (1.5 keV resolution at a base temperature of 130 mK) is demonstrated. Exploration of source deposition and encapsulation is underway. (orig.)

  9. Verification dosimetry of intravascular 90Sr/90Y source trains

    International Nuclear Information System (INIS)

    Sharma, S.D.; Shanta, A.; Tripathi, U.B.; Bhatt, B.C.

    2001-01-01

    90 Sr/ 90 Y source trains (Novoste Beta-Cath System) are currently under clinical trials in India and abroad for intracoronary brachytherapy for prevention of restenosis. Each source train of the Beta-Cath system is supplied with a source certificate giving dose rate at the reference distance of 2 mm from the centerline of the source train. It is essential that the user should check dose rates of brachytherapy sources before its application on the patients. Dose rates and depth dose measurements for 90 Sr/ 90 Y source trains of active length 40 mm using radiochromic films in a tissue equivalent phantom have been carried out. The objectives of these measurements were (1) to verify the dose rates stated in the source certificate, and (2) to obtain relative depth dose data for treatment planning. This paper presents the results of these measurements

  10. Regulation of glycogen synthase kinase-3{beta} (GSK-3{beta}) after ionizing radiation; Regulation der Glykogen Synthase Kinase-3{beta} (GSK-3{beta}) nach ionisierender Strahlung

    Energy Technology Data Exchange (ETDEWEB)

    Boehme, K.A.

    2006-12-15

    Glycogen Synthase Kinase-3{beta} (GSK-3{beta}) phosphorylates the Mdm2 protein in the central domain. This phosphorylation is absolutely required for p53 degradation. Ionizing radiation inactivates GSK-3{beta} by phosphorylation at serine 9 and in consequence prevents Mdm2 mediated p53 degradation. During the work for my PhD I identified Akt/PKB as the kinase that phosphorylates GSK-3{beta} at serine 9 after ionizing radiation. Ionizing radiation leads to phosphorylation of Akt/PKB at threonine 308 and serine 473. The PI3 Kinase inhibitor LY294002 completely abolished Akt/PKB serine 473 phosphorylation and prevented the induction of GSK-3{beta} serine 9 phosphorylation after ionizing radiation. Interestingly, the most significant activation of Akt/PKB after ionizing radiation occurred in the nucleus while cytoplasmic Akt/PKB was only weakly activated after radiation. By using siRNA, I showed that Akt1/PKBa, but not Akt2/PKB{beta}, is required for phosphorylation of GSK- 3{beta} at serine 9 after ionizing radiation. Phosphorylation and activation of Akt/PKB after ionizing radiation depends on the DNA dependent protein kinase (DNA-PK), a member of the PI3 Kinase family, that is activated by free DNA ends. Both, in cells from SCID mice and after knockdown of the catalytic subunit of DNA-PK by siRNA in osteosarcoma cells, phosphorylation of Akt/PKB at serine 473 and of GSK-3{beta} at serine 9 was completely abolished. Consistent with the principle that phosphorylation of GSK-3 at serine 9 contributes to p53 stabilization after radiation, the accumulation of p53 in response to ionizing radiation was largely prevented by downregulation of DNA-PK. From these results I conclude, that ionizing radiation induces a signaling cascade that leads to Akt1/PKBa activation mediated by DNA-PK dependent phosphorylation of serine 473. After activation Akt1/PKBa phosphorylates and inhibits GSK-3{beta} in the nucleus. The resulting hypophosphorylated form of Mdm2 protein is no longer

  11. High beta experiments in CHS

    International Nuclear Information System (INIS)

    Okamura, S.; Matsuoka, K.; Nishimura, K.

    1994-09-01

    High beta experiments were performed in the low-aspect-ratio helical device CHS with the volume-averaged equilibrium beta up to 2.1 %. These values (highest for helical systems) are obtained for high density plasmas in low magnetic field heated with two tangential neutral beams. Confinement improvement given by means of turning off gas puffing helped significantly to make high betas. Magnetic fluctuations increased with increasing beta, but finally stopped to increase in the beta range > 1 %. The coherent modes appearing in the magnetic hill region showed strong dependence on the beta values. The dynamic poloidal field control was applied to suppress the outward plasma movement with the plasma pressure. Such an operation gave fixed boundary operations of high beta plasmas in helical systems. (author)

  12. Calibration of a scintillation dosemeter for beta rays using an extrapolation ionization chamber

    International Nuclear Information System (INIS)

    Hakanen, A.T.; Sipilae, P.M.; Kosunen, A.

    2004-01-01

    A scintillation dosemeter is calibrated for 90 Sr/ 90 Y beta rays from an ophthalmic applicator, using an extrapolation ionization chamber as a reference instrument. The calibration factor for the scintillation dosemeter agrees with that given by the manufacturer of the dosemeter within ca. 2%. The estimated overall uncertainty of the present calibration is ca. 6% (2 sd). A calibrated beta-ray ophthalmic applicator can be used as a reference source for further calibrations performed in the laboratory or in the hospital

  13. Primary 4{pi}{beta}-{gamma} coincidence system for standardization of radionuclides by means of plastic scintillators; Sistema primario por coincidencias 4{pi}{beta}-{gamma} para a padronizacao de radionuclideos empregando cintiladores plasticos

    Energy Technology Data Exchange (ETDEWEB)

    Baccarelli, Aida Maria

    2003-07-01

    The present work describes a 4{pi}({alpha},{beta})-{gamma} coincidence system for absolute measurement of radionuclide activity using a plastic scintillator in 4{pi} geometry for charged particles detection and a Nal (Tl) crystal for gamma-ray detection. Several shapes and dimensions of the plastic scintillator have been tried in order to obtain the best system configuration. Radionuclides which decay by alpha emission, {beta}{sup -}, {beta}{sup +} and electron capture have been standardized. The results showed excellent agreement with other conventional primary system which makes use of a 4{pi} proportional counter for X-ray and charged particle detection. The system developed in the present work have some advantages when compared with the conventional systems, namely; it does not need metal coating on the films used as radioactive source holders. When compared to liquid scintillators, is showed the advantage of not needing to be kept in dark for more than 24 h to allow phosphorescence decay of ambient light. Therefore it can be set to count immediately after the sources are placed inside of it. (author)

  14. Conformation, molecular packing and field effect mobility of regioregular beta,beta'-dihexylsexithiophiophene

    DEFF Research Database (Denmark)

    Kiriy, N.; Kiriy, A.; Bocharova, V.

    2004-01-01

    by the pulse-radiolysis time-resolved microwave conductivity (PR-TRMC) technique was found to be Sigmamu(min) = 3.9 x 10(-3) cm(2) V-1 s(-1), which is comparable with the PR-TRMC mobility found for alpha,omega-DH6T. The field-effect mobility (FEM) of beta,beta'-DH6T was found to be on the order of 10(-5) cm(2......) V-1 s(-1), which is considerably less than the FEM of alpha,omega-DH6T. To understand the reason for such poor macroscopic electrical properties, the conformation and the molecular packing of beta,beta'-DH6T were systematically studied by means of UV-vis spectroscopy, scanning electron microscopy...... less dense crystalline packing than alpha,omega-DH6T. In contrast to the almost upright orientation of alpha,omega-DH6T molecules against the substrate (tilt angle about 68), the long axis of beta,beta'-DH6T molecules and the surface plane form an angle of similar to20degrees. Thus, the crystalline...

  15. Levered and unlevered Beta

    OpenAIRE

    Fernandez, Pablo

    2003-01-01

    We prove that in a world without leverage cost the relationship between the levered beta ( L) and the unlevered beta ( u) is the No-costs-of-leverage formula: L = u + ( u - d) D (1 - T) / E. We also analyze 6 alternative valuation theories proposed in the literature to estimate the relationship between the levered beta and the unlevered beta (Harris and Pringle (1985), Modigliani and Miller (1963), Damodaran (1994), Myers (1974), Miles and Ezzell (1980), and practitioners) and prove that all ...

  16. Construction of a 1 MeV Electron Accelerator for High Precision Beta Decay Studies

    Science.gov (United States)

    Longfellow, Brenden

    2014-09-01

    Beta decay energy calibration for detectors is typically established using conversion sources. However, the calibration points from conversion sources are not evenly distributed over the beta energy spectrum and the foil backing of the conversion sources produces perturbations in the calibration spectrum. To improve this, an external, tunable electron beam coupled by a magnetic field can be used to calibrate the detector. The 1 MeV electron accelerator in development at Triangle Universities Nuclear Laboratory (TUNL) utilizes a pelletron charging system. The electron gun shoots 104 electrons per second with an energy range of 50 keV to 1 MeV and is pulsed at a 10 kHz rate with a few ns width. The magnetic field in the spectrometer is 1 T and guiding fields of 0.01 to 0.05 T for the electron gun are used to produce a range of pitch angles. This accelerator can be used to calibrate detectors evenly over its energy range and determine the detector response over a range of pitch angles. Beta decay energy calibration for detectors is typically established using conversion sources. However, the calibration points from conversion sources are not evenly distributed over the beta energy spectrum and the foil backing of the conversion sources produces perturbations in the calibration spectrum. To improve this, an external, tunable electron beam coupled by a magnetic field can be used to calibrate the detector. The 1 MeV electron accelerator in development at Triangle Universities Nuclear Laboratory (TUNL) utilizes a pelletron charging system. The electron gun shoots 104 electrons per second with an energy range of 50 keV to 1 MeV and is pulsed at a 10 kHz rate with a few ns width. The magnetic field in the spectrometer is 1 T and guiding fields of 0.01 to 0.05 T for the electron gun are used to produce a range of pitch angles. This accelerator can be used to calibrate detectors evenly over its energy range and determine the detector response over a range of pitch angles

  17. High-$\\gamma$ Beta Beams within the LAGUNA design study

    CERN Document Server

    Orme, Christopher

    2010-01-01

    Within the LAGUNA design study, seven candidate sites are being assessed for their feasibility to host a next-generation, very large neutrino observatory. Such a detector will be expected to feature within a future European accelerator neutrino programme (Superbeam or Beta Beam), and hence the distance from CERN is of critical importance. In this article, the focus is a $^{18}$Ne and $^{6}$He Beta Beam sourced at CERN and directed towards a 50 kton Liquid Argon detector located at the LAGUNA sites: Slanic (L=1570 km) and Pyh\\"{a}salmi (L=2300 km). To improve sensitivity to the neutrino mass ordering, these baselines are then combined with a concurrent run with the same flux directed towards a large Water \\v{C}erenkov detector located at Canfranc (L=650 km). This degeneracy breaking combination is shown to provide comparable physics reach to the conservative Magic Baseline Beta Beam proposals. For $^{18}$Ne ions boosted to $\\gamma=570$ and $^{6}$He ions boosted to $\\gamma=350$, the correct mass ordering can be...

  18. Boosted beta regression.

    Directory of Open Access Journals (Sweden)

    Matthias Schmid

    Full Text Available Regression analysis with a bounded outcome is a common problem in applied statistics. Typical examples include regression models for percentage outcomes and the analysis of ratings that are measured on a bounded scale. In this paper, we consider beta regression, which is a generalization of logit models to situations where the response is continuous on the interval (0,1. Consequently, beta regression is a convenient tool for analyzing percentage responses. The classical approach to fit a beta regression model is to use maximum likelihood estimation with subsequent AIC-based variable selection. As an alternative to this established - yet unstable - approach, we propose a new estimation technique called boosted beta regression. With boosted beta regression estimation and variable selection can be carried out simultaneously in a highly efficient way. Additionally, both the mean and the variance of a percentage response can be modeled using flexible nonlinear covariate effects. As a consequence, the new method accounts for common problems such as overdispersion and non-binomial variance structures.

  19. Regulation of beta cell replication

    DEFF Research Database (Denmark)

    Lee, Ying C; Nielsen, Jens Høiriis

    2008-01-01

    Beta cell mass, at any given time, is governed by cell differentiation, neogenesis, increased or decreased cell size (cell hypertrophy or atrophy), cell death (apoptosis), and beta cell proliferation. Nutrients, hormones and growth factors coupled with their signalling intermediates have been...... suggested to play a role in beta cell mass regulation. In addition, genetic mouse model studies have indicated that cyclins and cyclin-dependent kinases that determine cell cycle progression are involved in beta cell replication, and more recently, menin in association with cyclin-dependent kinase...... inhibitors has been demonstrated to be important in beta cell growth. In this review, we consider and highlight some aspects of cell cycle regulation in relation to beta cell replication. The role of cell cycle regulation in beta cell replication is mostly from studies in rodent models, but whether...

  20. Determination of transmission factors for beta radiation at different experimental conditions

    International Nuclear Information System (INIS)

    Albuquerque, M. da P.P.; Caldas, L.V.E.

    1988-06-01

    During the transmission factors determination of beta radiation in air, using an ionization chamber with variable volume (extrapolation chamber), connected to a digital electrometer, and the secondary standard system constituted by the 90 Sr + 90 Y, 204 Tl and 147 Pm sources, the positioning of absorber materials equivalent to tissue, in relation to the detector and to the radiation sources is fundamental. In this work the absorbers were positioned in front of the sources, as well in front of the chamber, in different experiments, and the data were compared. (author) [pt

  1. Measurement of gross alpha and beta in air filter samples by using liquid scintillation counter

    International Nuclear Information System (INIS)

    Sudheendran, V.; Baburajan, A.; Gaikwad, R.H.; Ravi, P.M.; Tripathi, R.M.

    2015-01-01

    The determination of gross alpha and gross beta in particulate air filter samples was carried out by alpha, beta discrimination method using Liquid Scintillation Analyzer by setting the PSA value at 55 for 5 ml 0.1 HCl plus 15 ml of Ultima Gold AB cocktail by using 241 Am and 90 Sr/ 90 Y sources. The standardized method was compared with the gross alpha and gross beta activity determined by conventional method of direct counting with end window G.M. counter and ZnS (Ag). The minimum detectable activity of LSA method was found to be 9.3 mBq and 17.7 mBq for gross alpha and gross beta respectively for 6000 sec compared to the conventional method of 9.8 mBq and 189 mBq respectively at the same counting time. The result of analysis by both method indicate that the alpha, beta discrimination set up of LSA method is highly effective in the determination of low level alpha, beta activity in air filter samples. (author)

  2. Complement activation by the amyloid proteins A beta peptide and beta 2-microglobulin

    DEFF Research Database (Denmark)

    Nybo, Mads; Nielsen, E H; Svehag, S E

    1999-01-01

    component nor heparan sulfate did significantly alter the A beta-induced CA. The results indicate that not only fibrillar A beta but also oligomers of, in particular, beta 2M from patients with dialysis-associated amyloidosis are capable of inducing CA at supra-physiological concentrations....

  3. Supplementation of Carrot (Daucus carrota as Natural Source of Beta-carotene prepared by Several Methods in Feed to Increase Blue Colour of Freshwater Crayfish Red Claw (Cherax quadricarinatus

    Directory of Open Access Journals (Sweden)

    Woro H. Satyantini

    2012-02-01

    Full Text Available Red claw (Cherax quadricarinatus is one kind of freshwater crayfish that can cultured as consumption or ornamental fish commodities.  The colour of body was important character for performance of red claw as ornamental fish commodity.  Red claw with blue body colour is more expensive than brown.  The purpose of  this experiment was to know the influence addition of carrot with several methods in feed on blue colour  of freshwater crayfish red claw and which was the best preparation method to increase blue colour of freshwater crayfish red claw. The experiment used Completely Randomized Design with four treatments: A (control, B (extract, C (juice and D (shreeded of carrot with 45 ppm dose and five time replicates.  Data was analysed with Kruskal-Wallis and continued with Z test. Result of the experiment was showed that addition of carrot as natural source of beta-carotene with several preparation in feed increase significantly (P Keywords: freshwater crayfish, colour of red claw, carrot, beta-carotene   ABSTRAK Red claw (Cherax quadricarinatus adalah salah satu jenis lobster air tawar yang dapat dibudidayakan sebagai komoditas konsumsi maupun hias.  Sebagai komoditas ikan hias, warna tubuh merupakan karakter penting untuk menunjang penampilan red claw.  Red claw ukuran konsumsi yang memiliki warna biru akan memiliki nilai jual yang lebih tinggi daripada red claw berwarna coklat.  Tujuan penelitian ini untuk mengetahui pengaruh penambahan wortel sebagai sumber beta karoten alami dengan beberapa metoda pengolahan pada pakan terhadap peningkatan warna biru lobster red claw. Penelitian menggunakan Rancangan Acak Lengkap dengan 4 perlakuan : A (kontrol, B (ekstrak, C (jus dan D (serutan wortel dengan menggunakan dosis 45 ppm beta karoten dan ulangan 5 kali.  Data dianalisis dengan uji Kruskal-Wallis dan dilanjutkan dengan uji Z.  Hasil penelitian menunjukkan bahwa penambahan wortel sebagai sumber beta karoten alami dengan beberapa metode

  4. Dosimetry considerations in the replacement of Radon-222 sources by gold-198 sources for the treatment of patients

    International Nuclear Information System (INIS)

    Swindon, T.N.

    1978-10-01

    Radon-222 sources have been used in Australia for the treatment of patients since 1929 and the calculation of absorbed doses from such sources is well established. An alternative to radon-222 is gold-198 which, in suitable form, may be used for permanent implantations and for surface, interstitial or intra-cavitary applications. Because radon-222 and gold-198 have different characteristics, the data to be used in calculating the absorbed dose to a point in a treatment volume will depend on the particular source used. The data are related to the energies and abundances of the beta and gamma rays emitted from the nuclei and on their half-lives (Tsub(1/2)). The energies of the beta and gamma rays emitted by radon-222 (in equilibrium with its decay products) and by gold-198 are given

  5. Improved limits on beta(-) and beta(-) decays of Ca-48

    Czech Academy of Sciences Publication Activity Database

    Bakalyarov, A.; Balysh, A.; Barabash, AS.; Beneš, P.; Briancon, C.; Brudanin, V. B.; Čermák, P.; Egorov, V.; Hubert, F.; Hubert, P.; Korolev, NA.; Kosjakov, VN.; Kovalík, Alojz; Lebedev, NA.; Novgorodov, A. F.; Rukhadze, NI.; Štekl, NI.; Timkin, VV.; Veleshko, IE.; Vylov, T.; Umatov, VI.

    2002-01-01

    Roč. 76, č. 9 (2002), s. 545-547 ISSN 0021-3640 Institutional research plan: CEZ:AV0Z1048901 Keywords : beta decay * double beta decay * Ca-48 Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 1.483, year: 2002

  6. Double-beta decay measurement of 100Mo to the excited 01+ state of 100Ru in the NEMO3 experiment - R/D program for SuperNEMO: development of a BiPo detector to measure ultra low contaminations in the source foils

    International Nuclear Information System (INIS)

    Chapon, A.

    2011-10-01

    The NEMO3 detector was designed for the study of double beta decay and in particular the search for neutrinoless double beta decay (ββ0ν). The quantity of 100 Mo in the detector (7 kg) allows also a competitive measurement of the two-neutrino double beta decay (ββ2ν) of 100 Mo to the excited 0 1 + state of 100 Ru (eeNγ channel). Monte-Carlo simulations of the effect and of all the possible sources of background have been studied in order to determine their contributions to the full NEMO3 experimental data (2003-2011). These one have then been analysed: the ββ2ν decay half-life has been measured, and a limit on the ββ0ν decay has been obtained. Moreover, the SuperNEMO experiment aims to reach a sensitivity up to 10 26 years on the half-life of neutrinoless double beta decay. The SuperNEMO detector radioactivity has to be as low as possible. Especially radio-purity levels of 2 μBq*kg -1 in 208 Tl and 10 μBq*kg -1 in 214 Bi are required for the source foils. The gamma-spectrometry can not measure such low contamination levels. Hence, a BiPo dedicated detector has been developed to measure 208 Tl and 214 Bi contaminations, identifying the Bi→Po→Pb β-α chains. A proof of principle has been performed and the detector background has been measured. Assuming these values, a full BiPo detector of 3.6 m 2 can achieve the required sensitivities for the SuperNEMO source foils within six months of measurement. (author)

  7. Adrenocorticotropin, beta-endorphin, and beta-lipotropin in normal thyroid and lung: possible implications for ectopic hormone secretion.

    Science.gov (United States)

    Clements, J A; Funder, J W; Tracy, K; Morgan, F J; Campbell, D J; Lewis, P; Hearn, M T

    1982-12-01

    The expression of the proopiomelanocortin (POMC) gene by normal lung and thyroid was examined by measurement of the content of ACTH, beta-lipotropin (beta LPH), and beta-endorphin (beta EP) in porcine lung and thyroid tissue. Acid extracts of normal porcine lung and thyroid tissue each contained appreciable amounts of immunoreactive (ir) ACTH, ir-beta LPH, and ir-beta EP. The content of ir-beta LPH in both tissues exceeded by severalfold, on a molar basis, the content of ir-ACTH and ir-beta EP, suggesting that the common precursor POMC was processed predominantly to peptides other than ir-ACTH and ir-beta EP. A porcine thyroid extract (Calcitare, porcine calcitonin, Armour) showed equivalent levels of beta EP-like immunoreactivity and bioactivity, measured by opiate radioreceptor assay; in contrast, ACTH-like bioactivity, measured by rat zona fasciculata steroidogenesis, was only 4% of ACTH-like immunoreactivity. On reversed phase high performance liquid chromatography, Calcitare showed multiple peaks of ACTH-like immunoreactivity, one of which coeluted with porcine ACTH-(1-39), and two much smaller peaks of beta EP-like immunoreactivity, of which the smaller coeluted with porcine beta EP. These data suggest that both lung and thyroid gland synthesize POMC, which in normal tissue is usually predominantly processed to species other than ACTH and beta EP. Ectopic secretion of ACTH and beta EP by lung and thyroid neoplasms may thus represent the loss of a system(s) normally responsible for processing the precursor beyond ACTH and beta EP.

  8. Silencing of beta-carotene hydroxylase increases total carotenoid and beta-carotene levels in potato tubers

    Directory of Open Access Journals (Sweden)

    Pizzichini Daniele

    2007-03-01

    Full Text Available Abstract Background Beta-carotene is the main dietary precursor of vitamin A. Potato tubers contain low levels of carotenoids, composed mainly of the xanthophylls lutein (in the beta-epsilon branch and violaxanthin (in the beta-beta branch. None of these carotenoids have provitamin A activity. We have previously shown that tuber-specific silencing of the first step in the epsilon-beta branch, LCY-e, redirects metabolic flux towards beta-beta carotenoids, increases total carotenoids up to 2.5-fold and beta-carotene up to 14-fold. Results In this work, we silenced the non-heme beta-carotene hydroxylases CHY1 and CHY2 in the tuber. Real Time RT-PCR measurements confirmed the tuber-specific silencing of both genes . CHY silenced tubers showed more dramatic changes in carotenoid content than LCY-e silenced tubers, with beta-carotene increasing up to 38-fold and total carotenoids up to 4.5-fold. These changes were accompanied by a decrease in the immediate product of beta-carotene hydroxylation, zeaxanthin, but not of the downstream xanthophylls, viola- and neoxanthin. Changes in endogenous gene expression were extensive and partially overlapping with those of LCY-e silenced tubers: CrtISO, LCY-b and ZEP were induced in both cases, indicating that they may respond to the balance between individual carotenoid species. Conclusion Together with epsilon-cyclization of lycopene, beta-carotene hydroxylation is another regulatory step in potato tuber carotenogenesis. The data are consistent with a prevalent role of CHY2, which is highly expressed in tubers, in the control of this step. Combination of different engineering strategies holds good promise for the manipulation of tuber carotenoid content.

  9. Can pancreatic duct-derived progenitors be a source of islet regeneration?

    Energy Technology Data Exchange (ETDEWEB)

    Xia, Bing [Department of Endocrinology, First Hospital of Harbin Medical University, Harbin, Hei Long Jiang Province 150001 (China); Zhan, Xiao-Rong, E-mail: xiaorongzhan@sina.com [Department of Endocrinology, First Hospital of Harbin Medical University, Harbin, Hei Long Jiang Province 150001 (China); Yi, Ran [Department of Endocrinology, First Hospital of Harbin Medical University, Harbin, Hei Long Jiang Province 150001 (China); Yang, Baofeng [Department of Pharmacology, State Key Laboratory of Biomedicine and Pharmacology, Harbin Medical University, Harbin, Hei Long Jiang Province 150001 (China)

    2009-06-12

    The regenerative process of the pancreas is of interest because the main pathogenesis of diabetes mellitus is an inadequate number of insulin-producing {beta}-cells. The functional mass of {beta}-cells is decreased in type 1 diabetes, so replacing missing {beta}-cells or triggering their regeneration may allow for improved type 1 diabetes treatment. Therefore, expansion of the {beta}-cell mass from endogenous sources, either in vivo or in vitro, represents an area of increasing interest. The mechanism of islet regeneration remains poorly understood, but the identification of islet progenitor sources is critical for understanding {beta}-cell regeneration. One potential source is the islet proper, via the dedifferentiation, proliferation, and redifferentiation of facultative progenitors residing within the islet. Neogenesis, or that the new pancreatic islets can derive from progenitor cells present within the ducts has been reported, but the existence and identity of the progenitor cells have been debated. In this review, we focus on pancreatic ductal cells, which are islet progenitors capable of differentiating into islet {beta}-cells. Islet neogenesis, seen as budding of hormone-positive cells from the ductal epithelium, is considered to be one mechanism for normal islet growth after birth and in regeneration, and has suggested the presence of pancreatic stem cells. Numerous results support the neogenesis hypothesis, the evidence for the hypothesis in the adult comes primarily from morphological studies that have in common the production of damage to all or part of the pancreas, with consequent inflammation and repair. Although numerous studies support a ductal origin for new islets after birth, lineage-tracing experiments are considered the 'gold standard' of proof. Lineage-tracing experiments show that pancreatic duct cells act as progenitors, giving rise to new islets after birth and after injury. The identification of differentiated pancreatic ductal

  10. Metrological characteristics of the new BSS2 beta secondary standard system

    International Nuclear Information System (INIS)

    Reynaldo, Sibele R.

    2005-01-01

    Due to the increased interest and the importance of beta radiation dosimetry for radiation protection purposes, the Centro de Desenvolvimento da Tecnologia Nuclear. MG, Brazil, acquired the newest Beta Secondary Standard system (BSS2) in order to replace the old BSS1 model, with the goal of implement a beta radiation metrology laboratory and provide the corresponding reference radiation. The new system BSS2, unique in Latin America, requires operational testing and metrological characterization for reliability purposes. For this, some comparative investigations of the two systems were made. The influence of opening and closing the shutter in the final dose of radiation was identified as the highest in the BSS2 in relation to the one founded in BSS1, justified by the structural difference of the shutters of the systems and the reproducibility of source-detector geometry was better in BSS2, because of the robustness of the same

  11. Determinants of RNA polymerase alpha subunit for interaction with beta, beta', and sigma subunits: hydroxyl-radical protein footprinting.

    OpenAIRE

    Heyduk, T; Heyduk, E; Severinov, K; Tang, H; Ebright, R H

    1996-01-01

    Escherichia coli RNA polymerase (RNAP) alpha subunit serves as the initiator for RNAP assembly, which proceeds according to the pathway 2 alpha-->alpha 2-->alpha 2 beta-->alpha 2 beta beta'-->alpha 2 beta beta' sigma. In this work, we have used hydroxyl-radical protein footprinting to define determinants of alpha for interaction with beta, beta', and sigma. Our results indicate that amino acids 30-75 of alpha are protected from hydroxyl-radical-mediated proteolysis upon interaction with beta ...

  12. The Evaluation of the 0.07 and 3 mm Dose Equivalent with a Portable Beta Spectrometer

    Science.gov (United States)

    Hoshi, Katsuya; Yoshida, Tadayoshi; Tsujimura, Norio; Okada, Kazuhiko

    Beta spectra of various nuclide species were measured using a commercially available compact spectrometer. The shape of the spectra obtained via the spectrometer was almost similar to that of the theoretical spectra. The beta dose equivalent at any depth was obtained as a product of the measured pulse height spectra and the appropriate conversion coefficients of ICRP Publication 74. The dose rates evaluated from the spectra were comparable with the reference dose rates of standard beta calibration sources. In addition, we were able to determine the dose equivalents with a relative error of indication of 10% without the need for complicated correction.

  13. A study on the beta voltaic micro-nuclear battery based on the planar technology silicon detector

    International Nuclear Information System (INIS)

    Zhang Kai; He Gaokui; Huang Xiaojian; Liu Yang; Meng Xin; Hao Xiaoyong

    2011-01-01

    It describes briefly the beta voltaic micro-nuclear battery based on the planar technology silicon detector and radioisotope. Different sensitive area of silicon detectors are used to cooperate with 63 Ni source to buildup of beta voltaic micro-nuclear batteries. The experimental data show that the larger sensitive area the silicon detector has, the higher open circuit voltage it produces, and the open circuit voltage of single cell has reached an excellent result from 0.15 V to 0.30 V. It is possible to get high output power by series or parallel connecting the beta voltaic micro-nuclear batteries. (authors)

  14. {beta} - amyloid imaging probes

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Jae Min [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2007-04-15

    Imaging distribution of {beta} - amyloid plaques in Alzheimer's disease is very important for early and accurate diagnosis. Early trial of the {beta} -amyloid plaques includes using radiolabeled peptides which can be only applied for peripheral {beta} - amyloid plaques due to limited penetration through the blood brain barrier (BBB). Congo red or Chrysamine G derivatives were labeled with Tc-99m for imaging {beta} - amyloid plaques of Alzheimer patient's brain without success due to problem with BBB penetration. Thioflavin T derivatives gave breakthrough for {beta} - amyloid imaging in vivo, and a benzothiazole derivative [C-11]6-OH-BTA-1 brought a great success. Many other benzothiazole, benzoxazole, benzofuran, imidazopyridine, and styrylbenzene derivatives have been labeled with F-18 and I-123 to improve the imaging quality. However, [C-11]6-OH-BTA-1 still remains as the best. However, short half-life of C-11 is a limitation of wide distribution of this agent. So, it is still required to develop an Tc-99m, F-18 or I-123 labeled agent for {beta} - amyloid imaging agent.

  15. Isotope Effects in the Bonds of beta-CrOOH and beta-CrOOD

    DEFF Research Database (Denmark)

    Nørlund Christensen, A.; Hansen, P.; Lehmann, M. S.

    1976-01-01

    Samples of orthorhombic chromium oxide hydroxide, beta -CrOOH, and the deuterated compound, beta -CrOOD, were prepared hydrothermally. The crystal structures were determined by powder profile refinement technique using neutron diffraction data. Unit cells are: beta -CrOOH: a equals 4. 862(2) A, b...... equals 4. 298(a) A, c equals 2. 995(1) A; beta -CrOOD: a equals 4. 873(5) A, b equals 4. 332(7) A, c equals 2. 963(2) A, with Z equals 2. The space group is P2//1nm or Pnnm....

  16. Development of Simultaneous Beta-and-Coincidence-Gamma Imager for Plant Imaging Research

    Energy Technology Data Exchange (ETDEWEB)

    Tai, Yuan-Chuan [Washington Univ., St. Louis, MO (United States). School of Medicine

    2016-09-30

    The goal of this project is to develop a novel imaging system that can simultaneously acquire beta and coincidence gamma images of positron sources in thin objects such as leaves of plants. This hybrid imager can be used to measure carbon assimilation in plants quantitatively and in real-time after C-11 labeled carbon-dioxide is administered. A better understanding of carbon assimilation, particularly under the increasingly elevated atmospheric CO2 level, is extremely critical for plant scientists who study food crop and biofuel production. Phase 1 of this project is focused on the technology development with 3 specific aims: (1) develop a hybrid detector that can detect beta and gamma rays simultaneously; (2) develop an imaging system that can differentiate these two types of radiation and acquire beta and coincidence gamma images in real-time; (3) develop techniques to quantify radiotracer distribution using beta and gamma images. Phase 2 of this project is to apply technologies developed in phase 1 to study plants using positron-emitting radionuclide such as 11C to study carbon assimilation in biofuel plants.

  17. Antibodies against chromosomal beta-lactamase

    DEFF Research Database (Denmark)

    Giwercman, B; Rasmussen, J W; Ciofu, Oana

    1994-01-01

    A murine monoclonal anti-chromosomal beta-lactamase antibody was developed and an immunoblotting technique was used to study the presence of serum and sputum antibodies against Pseudomonas aeruginosa chromosomal group 1 beta-lactamase in patients with cystic fibrosis (CF). The serum antibody...... 1 cephalosporinase. We found a wide range of chromosomal beta-lactamase activity in the sputum samples, with no correlation with basal or induced activity of beta-lactamase expression. The presence of anti-beta-lactamase antibodies in endobronchial sputum could be an important factor in the defense...

  18. International Standardization of the Clinical Dosimetry of Beta Radiation Brachytherapy Sources: Progress of an ISO Standard

    Science.gov (United States)

    Soares, Christopher

    2006-03-01

    In 2004 a new work item proposal (NWIP) was accepted by the International Organization for Standardization (ISO) Technical Committee 85 (TC85 -- Nuclear Energy), Subcommittee 2 (Radiation Protection) for the development of a standard for the clinical dosimetry of beta radiation sources used for brachytherapy. To develop this standard, a new Working Group (WG 22 - Ionizing Radiation Dosimetry and Protocols in Medical Applications) was formed. The standard is based on the work of an ad-hoc working group initiated by the Dosimetry task group of the Deutsches Insitiut für Normung (DIN). Initially the work was geared mainly towards the needs of intravascular brachytherapy, but with the decline of this application, more focus has been placed on the challenges of accurate dosimetry for the concave eye plaques used to treat ocular melanoma. Guidance is given for dosimetry formalisms, reference data to be used, calibrations, measurement methods, modeling, uncertainty determinations, treatment planning and reporting, and clinical quality control. The document is currently undergoing review by the ISO member bodies for acceptance as a Committee Draft (CD) with publication of the final standard expected by 2007. There are opportunities for other ISO standards for medical dosimetry within the framework of WG22.

  19. Metalo-beta-lactamases Metallo-beta-lactamases

    Directory of Open Access Journals (Sweden)

    Rodrigo Elisandro Mendes

    2006-04-01

    Full Text Available Nos últimos anos tem sido observada maior incidência de bacilos Gram-negativos resistentes a cefalosporinas de espectro ampliado no ambiente hospitalar, ocasionando, assim, maior uso de betalactâmicos mais potentes, como os carbapenens. A utilização de carbapenens exerce maior pressão seletiva sobre a microbiota hospitalar, o que pode ocasionar aumento da resistência a esses agentes. Entre os mecanismos de resistência a carbapenens mais comumente identificados estão a produção de betalactamases, como, por exemplo, as pertencentes à classe D de Ambler e as que pertencem à classe B de Ambler, ou metalo-beta-lactamases (MbetaL. Essas últimas hidrolisam todos betalactâmicos comercialmente disponíveis, sendo a única exceção o monobactam aztreonam. Desde o início da década de 1990, novos genes que codificam MbetaLs têm sido descritos em microrganismos clinicamente importantes, como Pseudomonas spp., Acinetobacter spp. e membros da família Enterobacteriaceae. O encontro desses microrganismos não-sensíveis a carbapenens pode ser submetido a metodologias fenotípicas para detecção da produção de MbetaL com o intuito de auxiliar a Comissão de Controle de Infecção Hospitalar (CCIH e prevenir a disseminação desses determinantes de resistência, uma vez que genes que codificam MbetaLs estão contidos em estruturas genéticas que propiciam sua mobilidade de forma muito efetiva, sendo então facilmente disseminados.Increase isolation of Gram-negative bacilli resistant to broad-spectrum cephalosporin has been observed during the last few years, thus determining the use of more potent beta-lactams, such as carbapenems. The use of these antimicrobial agents may lead to the emergence of carbapenem resistant Gram-negative bacilli in the nosocomial environment. Carbapenem resistance may be due to the production of Ambler class D beta-lactamase or Ambler class B beta-lactamase, also called metallo-beta-lactamase (MbetaL. Apart from

  20. Beta limits for ETF

    International Nuclear Information System (INIS)

    Helton, F.J.; Miller, R.L.

    1982-01-01

    ETF (Engineering Test Facility) one-dimensional transport simulations indicate that a volume-average beta of 4% is required for ignition. It is therefore important that theoretical beta limits, determined by requiring equilibria to be stable to all ideal modes, exceed 4%. This paper documents an ideal MHD analysis wherein it is shown that, with appropriate plasma cross-sectional shape and current profile optimization, operation near 5% is possible. The critical beta value, however, depends on the functional form used for ff', which suggests that higher critical betas could be achieved by directly optimizing the safety factor profile. (author)

  1. Calibration of photon and beta ray sources used in brachytherapy. Guidelines on standardized procedures at Secondary Standards Dosimetry Laboratories; Calibracion de fuentes de fotones y rayos beta usadas en braquiterapia. Guia de procedimiento estandarizados en Laboratorios Secundarios de Calibracion Dosimetrica (LSCD) y en hospitales

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-03-01

    It has generally been recognized that international harmonization in radiotherapy dosimetry is essential. Consequently, the IAEA has given much effort to this, for example by publishing a number of reports in the Technical Reports Series (TRS) for external beam dosimetry, most notably TRS-277 and more recently TRS-398. Both of these reports describe in detail the steps to be taken for absorbed dose determination in water and they are often referred to as 'dosimetry protocols'. Similar to TRS-277, it is expected that TRS-398 will be adopted or used as a model by a large number of countries as their national protocol. In 1996, the IAEA established a calibration service for low dose rate (LDR) 137 Cs brachytherapy sources, which is the most widely used source for treatment of gynecological cancer. To further enhance harmonization in brachytherapy dosimetry, the IAEA published in 1999 IAEA-TECDOC-1079 entitled 'Calibration of Brachytherapy Sources. Guidelines on Standardized Procedures for the Calibration of Brachytherapy Sources at Secondary Standard Dosimetry Laboratories (SSDLs) and Hospitals'. The report was well received and was distributed in a large number of copies to the members of the IAEA/WHO network of SSDLs and to medical physicists working with brachytherapy. The present report is an update of the aforementioned TECDOC. Whereas TECDOC-1079 described methods for calibrating brachytherapy sources with photon energies at or above those of {sup 192}Ir, the current report has a wider scope in that it deals with standardization of calibration of all the most commonly used brachytherapy sources, including both photon and beta emitting sources. The latter sources have been in use for a few decades already, but their calibration methods have been unclear. Methods are also described for calibrating sources used in the rapidly growing field of cardiovascular angioplasty. In this application, irradiation of the vessel wall is done in an attempt to prevent restenosis

  2. Activity measurement of phosphorus-32 in the presence of pure beta-emitting impurities

    CSIR Research Space (South Africa)

    Simpson, B

    2006-02-27

    Full Text Available Activity measurements undertaken at the CSIR's National Metrology Laboratory (NML) on a solution of the pure beta-emitting radionuclide phosphorus-32, which formed part of an international key comparison, are described. Since exploratory source...

  3. Derivatives of the Incomplete Beta Function

    Directory of Open Access Journals (Sweden)

    Robert J. Boik

    1998-03-01

    Full Text Available The incomplete beta function is defined as where Beta(p, q is the beta function. Dutka (1981 gave a history of the development and numerical evaluation of this function. In this article, an algorithm for computing first and second derivatives of Ix,p,q with respect to p and q is described. The algorithm is useful, for example, when fitting parameters to a censored beta, truncated beta, or a truncated beta-binomial model.

  4. BetaShape: A new code for improved analytical calculations of beta spectra

    Directory of Open Access Journals (Sweden)

    Mougeot Xavier

    2017-01-01

    Full Text Available The new code BetaShape has been developed in order to improve the nuclear data related to beta decays. An analytical model was considered, except for the relativistic electron wave functions, for ensuring fast calculations. Output quantities are mean energies, log ft values and beta and neutrino spectra for single and multiple transitions. The uncertainties from the input parameters, read from an ENSDF file, are propagated. A database of experimental shape factors is included. A comparison over the entire ENSDF database with the standard code currently used in nuclear data evaluations shows consistent results for the vast majority of the transitions and highlights the improvements that can be expected with the use of BetaShape.

  5. Preventive Effects of Beta-Hydroxy-Beta-Methyl Butyrate

    OpenAIRE

    N. Ravanbakhsh; N. Torabi; M. Foadoddini

    2016-01-01

    Aims: One of the major factors in sudden cardiac arrest is the initiation and continuation of deadly arrhythmias during ischemia. It is known that beta-hydroxy-beta-methylbutyrate (HMB) has useful effects such as anti-inflammatory and anti-apoptosis effects in the skeletal muscles. The aim of this study was to investigate the preventive effects of HMB on the ventricular arrhythmias due to the ischemia. Materials & Methods: In the experimental study, 30 Wistar male rats were randomly div...

  6. Beta-thalassemia

    Directory of Open Access Journals (Sweden)

    Origa Raffaella

    2010-05-01

    Full Text Available Abstract Beta-thalassemias are a group of hereditary blood disorders characterized by anomalies in the synthesis of the beta chains of hemoglobin resulting in variable phenotypes ranging from severe anemia to clinically asymptomatic individuals. The total annual incidence of symptomatic individuals is estimated at 1 in 100,000 throughout the world and 1 in 10,000 people in the European Union. Three main forms have been described: thalassemia major, thalassemia intermedia and thalassemia minor. Individuals with thalassemia major usually present within the first two years of life with severe anemia, requiring regular red blood cell (RBC transfusions. Findings in untreated or poorly transfused individuals with thalassemia major, as seen in some developing countries, are growth retardation, pallor, jaundice, poor musculature, hepatosplenomegaly, leg ulcers, development of masses from extramedullary hematopoiesis, and skeletal changes that result from expansion of the bone marrow. Regular transfusion therapy leads to iron overload-related complications including endocrine complication (growth retardation, failure of sexual maturation, diabetes mellitus, and insufficiency of the parathyroid, thyroid, pituitary, and less commonly, adrenal glands, dilated myocardiopathy, liver fibrosis and cirrhosis. Patients with thalassemia intermedia present later in life with moderate anemia and do not require regular transfusions. Main clinical features in these patients are hypertrophy of erythroid marrow with medullary and extramedullary hematopoiesis and its complications (osteoporosis, masses of erythropoietic tissue that primarily affect the spleen, liver, lymph nodes, chest and spine, and bone deformities and typical facial changes, gallstones, painful leg ulcers and increased predisposition to thrombosis. Thalassemia minor is clinically asymptomatic but some subjects may have moderate anemia. Beta-thalassemias are caused by point mutations or, more rarely

  7. Dry-boxes for manipulation of high-energy {beta} emitters; Bottes pour manipulation d'emetteurs {beta} energiques

    Energy Technology Data Exchange (ETDEWEB)

    Boclet, K; Laurent, H [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    Because of the thinners of latex or neoprene gloves and the high intensity of Bremsstrahlung radiation, manipulation of pure high-energy {beta}{sup -} emitters is impossible in ordinary dry-boxes. There are many types of box equipped with heavy lead or steel protection, but their use for radioelements such as {sup 32}P, {sup 90}Sr, {sup 90}Y is not justified. We have devised units known as 'tong boxes' which, while retaining much of the flexibility of operation found in dry-boxes, provide adequate protection. 1 curie of {sup 32}P placed in the centre of the enclosure gives about 15 mR/ 8 h. at the part of the wall closest to the source. (author) [French] La faible epaisseur des gants de latex ou de neoprene et l'importance du rayonnement de freinage rendent impossible la manipulation des emetteurs {beta}{sup -} purs energiques dans des boites a gants normales. Il existe de nombreux types d'enceintes dotees d'une forte protection de plomb ou d'acier dont l'emploi n'est pas justifie pour des radioelements tels que {sup 32}P, {sup 90}Sr, {sup 90}Y. Nous avons realise des ensembles appeles 'Boites a Pinces', qui tout en conservant une grande partie de la souplesse d'utilisation des boites a gants sont dotees d'une protection suffisante. 1 curie de {sup 32}P place au centre de l'enceinte donne environ 15 mR/ 8 h au contact de la paroi la plus rapprochee de la source. (auteur)

  8. Investigation of beta ray attenuation in CaSO4:Dy(Tm)-teflon rods

    International Nuclear Information System (INIS)

    Szabo, P.P.

    1990-12-01

    Ultrathin discs were prepared from CaSO 4 :Dy(Tm)-teflon rods by cutting them with a microtom. The effect of cutting was studied experimentally. It was found that the cutting does not affect the TL signal of the discs, so one will be able to irradiate the rod and cut it afterwards which means that this method can be applied in the dosimetry of boundaries or to establish the energy of beta radiation. Depth dose distribution measurements were carried out by irradiating the rods with beta sources. (K.A.) 5 refs.; 6 figs

  9. 17Beta-hydroxysteroid dehydrogenase (17beta-HSD) in scleractinian corals and zooxanthellae.

    Science.gov (United States)

    Blomquist, Charles H; Lima, P H; Tarrant, A M; Atkinson, M J; Atkinson, S

    2006-04-01

    Steroid metabolism studies have yielded evidence of 17beta-hydroxysteroid dehydrogenase (17beta-HSD) activity in corals. This project was undertaken to clarify whether there are multiple isoforms of 17beta-HSD, whether activity levels vary seasonally, and if zooxanthellae contribute to activity. 17Beta-HSD activity was characterized in zooxanthellate and azooxanthellate coral fragments collected in summer and winter and in zooxanthellae cultured from Montipora capitata. More specifically, 17beta-HSD activity was characterized with regard to steroid substrate and inhibitor specificity, coenzyme specificity, and Michaelis constants for estradiol (E2) and NADP+. Six samples each of M. capitata and Tubastrea coccinea (three summers, three winters) were assayed with E2 and NADP+. Specific activity levels (pmol/mg protein) varied 10-fold among M. capitata samples and 6-fold among T. coccinea samples. There was overlap of activity levels between summer and winter samples. NADP+/NAD+ activity ratios varied from 1.6 to 22.2 for M. capatita, 2.3 to 3.8 for T. coccinea and 0.7 to 1.1 for zooxanthellae. Coumestrol was the most inhibitory of the steroids and phytoestrogens tested. Our data confirm that corals and zooxanthellae contain 17beta-HSD and are consistent with the presence of more than one isoform of the enzyme.

  10. Blood flow measurements in the irradiated pig skin using {beta} emitters radionuclides; Mesure de la circulation sanguine cutanee chez le porc irradie a l`aide de radioisotopes emetteurs {beta}

    Energy Technology Data Exchange (ETDEWEB)

    Daburon, F; Lefaix, J L; Leplat, J J; Fayart, G; Delacroix, D; Le Thanh, P

    1997-01-01

    Non invasive methods of study of the skin blood flow are numerous, but generally do not give any indication on the cutaneous micro-circulatory flow, except for cutaneous laser Doppler. The isotopic exploration of the skin with injected {gamma} radionuclides, even of weak energy, doe snot allow to characterize the skin blood flow, because of the important contribution of the subcutaneous tissues. The use of {beta} emitters energy spectrum, analyzed by different quantitative methods, are proportional to the thickness of the screen localized between the radioactive source and detector. Using simple and complex phantoms composed of tissue equivalent screens, with {sup 32}P sources placed at different depths, it was possible to study the degradation of {beta} spectra, simulating respectively the sub-epidermis and sub-dermis vascular levels. A modelization and an experimental study in-vivo are proposed in this work, with {sup 32}P phosphate administered intravenously in pigs. (author).

  11. Dose point kernels for beta-emitting radioisotopes

    International Nuclear Information System (INIS)

    Prestwich, W.V.; Chan, L.B.; Kwok, C.S.; Wilson, B.

    1986-01-01

    Knowledge of the dose point kernel corresponding to a specific radionuclide is required to calculate the spatial dose distribution produced in a homogeneous medium by a distributed source. Dose point kernels for commonly used radionuclides have been calculated previously using as a basis monoenergetic dose point kernels derived by numerical integration of a model transport equation. The treatment neglects fluctuations in energy deposition, an effect which has been later incorporated in dose point kernels calculated using Monte Carlo methods. This work describes new calculations of dose point kernels using the Monte Carlo results as a basis. An analytic representation of the monoenergetic dose point kernels has been developed. This provides a convenient method both for calculating the dose point kernel associated with a given beta spectrum and for incorporating the effect of internal conversion. An algebraic expression for allowed beta spectra has been accomplished through an extension of the Bethe-Bacher approximation, and tested against the exact expression. Simplified expression for first-forbidden shape factors have also been developed. A comparison of the calculated dose point kernel for 32 P with experimental data indicates good agreement with a significant improvement over the earlier results in this respect. An analytic representation of the dose point kernel associated with the spectrum of a single beta group has been formulated. 9 references, 16 figures, 3 tables

  12. Beta irradiation as a method of the static MOS RAM memories processing and circuit design verification

    International Nuclear Information System (INIS)

    Wislowski, J.; Jagusztyn, M.

    1985-01-01

    1K NMOS RAM's in plastic packages were investigated after beta irradiation up to 100 Gy (Si) total dose. The memory samples differed as regards processing details and circuit design. Radioisotope beta sources were used for irradiation as the most safe and least expensive. A new version of the model of radiation-induced functional degradation of MOS RAM's has been proposed. 19 refs., 8 figs., 5 tabs. (author)

  13. Rapid method of identification of {beta}-ray emitters and of {beta}-radioactive impurity dosage (1961); Methode rapide d'identification des emetteurs-{beta} et de dosage d'impuretes radioactives-{beta} (1961)

    Energy Technology Data Exchange (ETDEWEB)

    Le Gallic, Y; Legrand, J; Grinberg, B [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1961-07-01

    We describe a simple method of radioactive analysis, which allows an accurate determination of maximal energies of {beta}-emitters, and detection and titration of radioactive impurities in radionuclides as well. The method described, which uses a plastic scintillator, is based on the fact that the curve obtained by plotting the number of pulses measured against the threshold is a straight line, in the case of pure {beta}-emitters. We then derive a simple relation between the data of this straight line and the maximal energy of the {beta}-spectrum of the radionuclide under consideration. (authors) [French] Description d'une methode simple d'analyse radioactive, permettant de determiner avec precision l'energie maximum des emetteurs-{beta}, ainsi que de deceler et de doser les impuretes radioactives dans un radionuclide. La technique decrite utilise un scintillateur plastique. On exploite le fait que la courbe du nombre d'impulsions mesurees, en fonction du seuil de discrimination, est une droite, pour un emetteur-{beta} pur. Une relation simple entre les caracteristiques de cette droite et l'energie maximum du spectre-{beta} du radionuclide, correspondant, a ete etablie. (auteurs)

  14. Human APC sequesters beta-catenin even in the absence of GSK-3beta in a Drosophila model.

    Science.gov (United States)

    Rao, P R; Makhijani, K; Shashidhara, L S

    2008-04-10

    There have been conflicting reports on the requirement of GSK-3beta-mediated phosphorylation of the tumor suppressor adenomatous polyposis coli (APC) vis-à-vis its ability to bind and degrade beta-catenin. Using a unique combination of loss of function for Shaggy/GSK-3beta and a gain of function for human APC in Drosophila, we show that misexpressed human APC (hAPC) can still sequester Armadillo/beta-catenin. In addition, human APC could suppress gain of Wnt/Wingless phenotypes associated with loss of Shaggy/GSK-3beta activity, suggesting that sequestered Armadillo/beta-catenin is non-functional. Based on these studies, we propose that binding per se of beta-catenin by APC does not require phosphorylation by GSK-3beta.

  15. Genetics Home Reference: beta thalassemia

    Science.gov (United States)

    ... Facebook Twitter Home Health Conditions Beta thalassemia Beta thalassemia Printable PDF Open All Close All Enable Javascript to view the expand/collapse boxes. Description Beta thalassemia is a blood disorder that reduces the production ...

  16. The effects of beta-carotene and vitamin E on erythrocytes lipid peroxidation in beta-thalassemia patients

    Directory of Open Access Journals (Sweden)

    Soleiman Mahjoub

    2007-12-01

    Full Text Available BACKGROUND: Thalassemia is the most common hereditary disease in the world. Thalassemic erythrocytes are exposed to higher oxidative stress and lipid peroxidation. The aim of this study was to investigate the effects of beta-carotene and vitamin E on erythrocytes lipid peroxidation in beta-thalassemia patients.
    METHODS: A prospective double-blind, placebo-controlled study of the effect of beta-carotene and vitamin E on lipid peroxidation in erythrocytes membranes was performed on 120 beta-thalassemia major patients in four groups. The patients were supplemented for 4 weeks as follows: group 1 with beta-carotene (13 mg/day, group 2 with vitamin E (550 mg/day, group 3 with beta-carotene plus vitamin E and group 4 with placebo. We prepared all capsules for 4 roups in the same shape and color. Measurements of serum beta-carotene and vitamin E were performed by high performance
    liquid chromatography. After preparation of ghost cells from blood specimens, malondialdehyde (MDA was determined as index of lipid peroxidation in erythrocytes membranes before and after treatment. RESULTS: The levels of serum beta-carotene and vitamin E were significantly lower and MDA concentrations in erythrocytes membranes were significantly higher in beta-thalassemia patients compared to controls (P<0.001. In groups that treated with vitamin supplements for 4-weeks, lipid peroxidation rates were significantly reduced after treatment (P<0.001, but in placebo group there was not significant difference (P>0.05.
    CONCLUSIONS: Our findings provide evidence that an oral treatment with beta-carotene and vitamin E can significantly reduce lipid peroxidation of erythrocytes membranes and could be useful in management of beta-thalassemia major patients. KEYWORDS: Beta-thalassemia major, beta-carotene, vitamin E, malondialdehyde, lipid peroxidation.

  17. Source of monoenergetic electrons for beta dosimetry

    International Nuclear Information System (INIS)

    Graham, C.L.; Elliott, J.H.

    1983-01-01

    We have developed an electron spectrometer which can produce a continuous beam of monoenergetic electrons. The spectrometer uses 20 millicuries of Cs-137 as a source of electrons which can be magnetically focused at the exit port. Various electron energies can be selected by changing the magnetic field. The maximum electron energy and dose rate for the present design are approximately 630 keV and 1.5 rads per hour, respectively

  18. Measurement of the energy dependent beta asymmetry in the decay of 8Li

    International Nuclear Information System (INIS)

    Bigelow, R.A.; Quin, P.A.; Freedman, S.J.; Napolitano, J.

    1985-01-01

    Progress is reported on a new measurement of the beta decay asymmetry in 8 Li. Polarized 8 Li is produced via the reaction 7 Li(d,p) 8 Li using vector polarized deuterons from a crossed beam polarized source. Plastic scintillation electron counters are used to measure asymmetry, tensor polarization correlation and to monitor beam current. Results are graphed and systematic error sources are discussed. 4 refs

  19. Low Horizontal Beta Function In Long Straights Of The NSLS-II Lattice

    International Nuclear Information System (INIS)

    Fanglei, L.; Bengtsson, J.; Guo, W.; Krinsky, S.; Li, Y.; Yang, L.

    2011-01-01

    The NSLS-II storage ring lattice is comprised of 30 DBA cells arranged in 15 superperiods. There are 15 long straight sections (9.3m) for injection, RF and insertion devices and 15 short straights (6.6m) for insertion devices. In the baseline lattice, the short straights have small horizontal and vertical beta functions but the long straights have large horizontal beta function optimized for injection. In this paper, we explore the possibility of maintaining three long straights with large horizontal beta function while providing the other 12 long straights with smaller horizontal beta function to optimize the brightness of insertion devices. Our study considers the possible linear lattice solutions as well as characterizing the nonlinear dynamics. Results are reported on optimization of dynamic aperture required for good injection efficiency and adequate Touschek lifetime. This paper discusses dynamic aperture optimization for the NSLS-II lattice with alternate high and low horizontal beta function in the long straights, which is proposed for the optimization of the brightness of insertion devices. The linear optics is optimized to meet the requirements of lattice function and source properties. Nonlinear optimization for a lattice with working point at (37.18, 16.2) is performed. Considering the realistic magnets errors and physical apertures, we calculate the frequency maps and plot the tune footprint. The results show that the lattice with high-low beta function has adequate dynamic aperture for good injection efficiency and sufficient Touschek lifetime.

  20. Inhibitory effect of different product analogues on {beta}-alanine synthase: A thermodynamic and fluorescence analysis

    Energy Technology Data Exchange (ETDEWEB)

    Andujar-Sanchez, Montserrat; Martinez-Gomez, Ana Isabel; Martinez-Rodriguez, Sergio; Clemente-Jimenez, Josefa Maria; Heras-Vazquez, Francisco Javier Las; Rodriguez-Vico, Felipe [Departamento de Quimica Fisica, Bioquimica y Quimica Inorganica, Facultad de Ciencias Experimentales, Universidad de Almeria, Carretera de Sacramento s/n, La Canada de San Urbano, Almeria 04120 (Spain); Jara-Perez, Vicente [Departamento de Quimica Fisica, Bioquimica y Quimica Inorganica, Facultad de Ciencias Experimentales, Universidad de Almeria, Carretera de Sacramento s/n, La Canada de San Urbano, Almeria 04120 (Spain)], E-mail: vjara@ual.es

    2009-02-15

    The enzyme N-carbamoyl-{beta}-alanine amidohydrolase catalyse the hydrolysis of N-carbamoyl-{beta}-alanine or N-carbamoyl-{beta}-aminoisobutyric acid to {beta}-alanine or 3-aminoisobutyric acid, under the release of carbon-dioxide and ammonia. This work studies the inhibition of N-carbamoyl-{beta}-alanine amidohydrolase from Agrobacterium tumefaciens C58 (At{beta}car) by different carboxylic acid compounds that differ in number of carbons, and position and size of ramification, while the binding thermodynamics of the inhibitors are studied by isothermal titration calorimetry (ITC) and fluorescence. From the binding constants and inhibition studies, we conclude that propionate is the most efficient inhibitor among those tested. Substitution of the linear alkyl acids in positions 2 and 3 resulted in a drastic decrease of the affinity. The thermodynamic parameters show that a conformational change is triggered upon ligand binding. Binding enthalpy {delta}H{sub b} is negative in all cases for all ligands, and thus, Van der Waals interactions and hydrogen bonding are most probably the major sources for this term. The process is entropically favoured at all temperatures and pH studied, most probably due to the liberation of water molecules accompanying the conformational change of the enzyme.

  1. Hanford beta-gamma personnel dosimeter prototypes and evaluation

    International Nuclear Information System (INIS)

    Fix, J.J.; Holbrook, K.L.; Soldat, K.L.

    1983-04-01

    Upgraded and modified Hanford dosimeter prototypes were evaluated for possible use at Hanford as a primary beta-gamma dosimeter. All prototypes were compatible with the current dosimeter card and holder design, as well as processing with the automated Hanford readers. Shallow- and deep-dose response was determined for selected prototypes using several beta sources, K-fluorescent x rays and filtered x-ray techniques. All prototypes included a neutron sensitive chip. A progressive evaluation of the performance of each of the upgrades to the current dosimeter is described. In general, the performance of the current dosimeter can be upgraded using individual chip sensitivity factors to improve precision and an improved algorithm to minimize bias. The performance of this dosimeter would be adequate to pass all categories of the ANSI N13.11 performance criteria for dosimeter procesors, provided calibration techniques compatible with irradiations adopted in the standard were conducted. The existing neutron capability of the dosimeter could be retained. Better dosimeter performance to beta-gamma radiation can be achieved by modifying the Hanford dosimeter so that four of the five chip positions are devoted to calculating these doses instead of the currently used two chip positions. A neutron sensitive chip was used in the 5th chip position, but all modified dosimeter prototypes would be incapable of discriminating between thermal and epithermal neutrons. An improved low energy beta response can be achieved for the current dosimeter and all prototypes considered by eliminating the security credential. Further improvement can be obtained by incorporating the 15-mil thick TLD-700 chips

  2. Latin American food sources of carotenoids.

    Science.gov (United States)

    Rodriguez-Amaya, D B

    1999-09-01

    Latin America has a wide variety of carotenogenic foods, notable for the diversity and high levels of carotenoids. A part of this natural wealth has been analyzed. Carrot, red palm oil and some cultivars of squash and pumpkin are sources of both beta-carotene and alpha-carotene. beta-carotene is the principal carotenoid of the palm fruits burití, tucumã and bocaiuva, other fruits such as loquat, marolo and West Indian cherry, and sweet potato. Buriti also has high amounts of alpha-carotene and gamma-carotene. beta-Cryptoxanthin is the major carotenoid in caja, nectarine, orange-fleshed papaya, orange, peach, tangerine and the tree tomato. Lycopene predominates in tomato, red-fleshed papaya, guava, pitanga and watermelon. Pitanga also has substantial amounts of beta-cryptoxanthin, gamma-carotene and rubixanthin. Zeaxanthin, principal carotenoid of corn, is also predominant only in piquí. delta-Carotene is the main carotenoid of the peach palm and zeta-carotene of passion fruit. Lutein and beta-carotene, in high concentrations, are encountered in the numerous leafy vegetables of the region, as well as in other green vegetables and in some varieties of squash and pumpkin. Violaxanthin is the principal carotenoid of mango and mamey and is also found in appreciable amounts in green vegetables. Quantitative, in some cases also qualitative, differences exist among cultivars of the same food. Generally, carotenoids are in greater concentrations in the peel than in the pulp, increase considerably during ripening and are in higher levels in foods produced in hot places. Other Latin America indigenous carotenogenic foods must be investigated before they are supplanted by introduced crops, which are often poorer sources of carotenoids.

  3. Constraining the Mass Loss Geometry of Beta Lyrae

    Directory of Open Access Journals (Sweden)

    Jamie R. Lomax

    2012-03-01

    Full Text Available Massive binary stars lose mass by two mechanisms: jet-driven mass loss during periods of active mass transfer and by wind-driven mass loss. Beta Lyrae is an eclipsing, semi-detached binary whose state of active mass transfer provides a unique opportunity to study how the evolution of binary systems is affected by jet-driven mass loss. Roche lobe overflow from the primary star feeds the thick accretion disk which almost completely obscures the mass-gaining star. A hot spot predicted to be on the edge of the accretion disk may be the source of beta Lyrae’s bipolar outflows. I present results from spectropolarimetric data taken with the University of Wisconsin’s Half-Wave Spectropolarimeter and the Flower and Cook Observatory’s photoelastic modulating polarimeter instrument which have implications for our current understanding of the system’s disk geometry. Using broadband polarimetric analysis, I derive new information about the structure of the disk and the presence and location of a hot spot. These results place constraints on the geometrical distribution of material in beta Lyrae and can help quantify the amount of mass lost from massive interacting binary systems during phases of mass transfer and jet-driven mass loss.

  4. Evaluation of partial beta-adrenoceptor agonist activity.

    Science.gov (United States)

    Lipworth, B J; Grove, A

    1997-01-01

    A partial beta-adrenoceptor (beta-AR) agonist will exhibit opposite agonist and antagonist activity depending on the prevailing degree of adrenergic tone or the presence of a beta-AR agonist with higher intrinsic activity. In vivo partial beta-AR agonist activity will be evident at rest with low endogenous adrenergic tone, as for example with chronotropicity (beta 1/beta 2), inotropicity (beta 1) or peripheral vasodilatation and finger tremor (beta 2). beta-AR blocking drugs which have partial agonist activity may exhibit a better therapeutic profile when used for hypertension because of maintained cardiac output without increased systemic vascular resistance, along with an improved lipid profile. In the presence of raised endogenous adrenergic tone such as exercise or an exogenous full agonist, beta-AR subtype antagonist activity will become evident in terms of effects on exercise induced heart rate (beta 1) and potassium (beta 2) responses. Reduction of exercise heart rate will occur to a lesser degree in the case of a beta-adrenoceptor blocker with partial beta 1-AR agonist activity compared with a beta-adrenoceptor blocker devoid of partial agonist activity. This may result in reduced therapeutic efficacy in the treatment of angina on effort when using beta-AR blocking drugs with partial beta 1-AR agonist activity. Effects on exercise hyperkalaemia are determined by the balance between beta 2-AR partial agonist activity and endogenous adrenergic activity. For predominantly beta 2-AR agonist such as salmeterol and salbutamol, potentiation of exercise hyperkalaemia occurs. For predominantly beta 2-AR antagonists such as carteolol, either potentiation or attenuation of exercise hyperkalaemia occurs at low and high doses respectively. beta 2-AR partial agonist activity may also be expressed as antagonism in the presence of an exogenous full agonist, as for example attenuation of fenoterol induced responses by salmeterol. Studies are required to investigate whether

  5. Development of a low-energy and high-current pulsed neutral beam injector with a washer-gun plasma source for high-beta plasma experiments.

    Science.gov (United States)

    Ii, Toru; Gi, Keii; Umezawa, Toshiyuki; Asai, Tomohiko; Inomoto, Michiaki; Ono, Yasushi

    2012-08-01

    We have developed a novel and economical neutral-beam injection system by employing a washer-gun plasma source. It provides a low-cost and maintenance-free ion beam, thus eliminating the need for the filaments and water-cooling systems employed conventionally. In our primary experiments, the washer gun produced a source plasma with an electron temperature of approximately 5 eV and an electron density of 5 × 10(17) m(-3), i.e., conditions suitable for ion-beam extraction. The dependence of the extracted beam current on the acceleration voltage is consistent with space-charge current limitation, because the observed current density is almost proportional to the 3/2 power of the acceleration voltage below approximately 8 kV. By optimizing plasma formation, we successfully achieved beam extraction of up to 40 A at 15 kV and a pulse length in excess of 0.25 ms. Its low-voltage and high-current pulsed-beam properties enable us to apply this high-power neutral beam injection into a high-beta compact torus plasma characterized by a low magnetic field.

  6. Beta2- and beta3-adrenoceptors activate glucose uptake in chick astrocytes by distinct mechanisms: a mechanism for memory enhancement?

    Science.gov (United States)

    Hutchinson, Dana S; Summers, Roger J; Gibbs, Marie E

    2007-11-01

    Isoprenaline, acting at beta-adrenoceptors (ARs), enhances memory formation in single trial discriminated avoidance learning in day-old chicks by mechanisms involving alterations in glucose and glycogen metabolism. Earlier studies of memory consolidation in chicks indicated that beta3-ARs enhanced memory by increasing glucose uptake, whereas beta2-ARs enhance memory by increasing glycogenolysis. This study examines the ability of beta-ARs to increase glucose uptake in chick forebrain astrocytes. The beta-AR agonist isoprenaline increased glucose uptake in a concentration-dependent manner, as did insulin. Glucose uptake was increased by the beta2-AR agonist zinterol and the beta3-AR agonist CL316243, but not by the beta1-AR agonist RO363. In chick astrocytes, reverse transcription-polymerase chain reaction studies showed that beta1-, beta2-, and beta3-AR mRNA were present, whereas radioligand-binding studies showed the presence of only beta2- and beta3-ARs. beta-AR or insulin-mediated glucose uptake was inhibited by phosphatidylinositol-3 kinase and protein kinase C inhibitors, suggesting a possible interaction between the beta-AR and insulin pathways. However beta2- and beta3-ARs increase glucose uptake by two different mechanisms: beta2-ARs via a Gs-cAMP-protein kinase A-dependent pathway, while beta3-ARs via interactions with Gi. These results indicate that activation of beta2- and beta3-ARs causes glucose uptake in chick astrocytes by distinct mechanisms, which may be relevant for memory enhancement.

  7. Beta response of CaSO4:Dy based TLD badge and its angular dependence studies for personnel monitoring applications

    International Nuclear Information System (INIS)

    Kumar, Munish; Rakesh, R.B.; Sneha, C.; Ratna, P.; Bakshi, A.K.; Datta, D.

    2016-01-01

    In India, shallow/skin doses received by radiation workers from beta particles are measured using CaSO 4 :Dy based Teflon embedded TLD badge. The beta particles having maximum energy E max > 0.6 MeV - ≥ 3.54 MeV are monitored. The ratio of the response of discs under open and plastic regions (D Open/ D Perspex ) is used to estimate the energy of the beta source and to apply response correction factor. This is required as the disc dosimeters are thick and exhibit energy dependent response. Due to lack of comprehensive information regarding disc ratios and associated beta multiplication/response correction factors, present study was performed

  8. BETA (Bitter Electromagnet Testing Apparatus)

    Science.gov (United States)

    Bates, Evan M.; Birmingham, William J.; Rivera, William F.; Romero-Talamas, Carlos A.

    2017-10-01

    The Bitter Electromagnet Testing Apparatus (BETA) is a 1-Tesla (T) prototype of the 10-T Adjustable Long Pulse High-Field Apparatus (ALPHA). These water-cooled resistive magnets use high DC currents to produce strong uniform magnetic fields. Presented here is the successful completion of the BETA project and experimental results validating analytical magnet designing methods developed at the Dusty Plasma Laboratory (DPL). BETA's final design specifications will be highlighted which include electromagnetic, thermal and stress analyses. The magnet core design will be explained which include: Bitter Arcs, helix starters, and clamping annuli. The final version of the magnet's vessel and cooling system are also presented, as well as the electrical system of BETA, which is composed of a unique solid-state breaker circuit. Experimental results presented will show the operation of BETA at 1 T. The results are compared to both analytical design methods and finite element analysis calculations. We also explore the steady state maximums and theoretical limits of BETA's design. The completion of BETA validates the design and manufacturing techniques that will be used in the succeeding magnet, ALPHA.

  9. Prevalence of Co-Inheritance of Alpha-Thalassemia with Beta-Thalassemia and Beta-Hemoglobinopathy in Ahvaz City

    Directory of Open Access Journals (Sweden)

    Najmaddin Saki

    2013-09-01

    Full Text Available Background: Co-inheritance of hemoglobin gene defects is a rare important status that can lead to double heterozygote or homozygote with significant clinical manifestations. Such conditions can be observed in co-inheritance of alpha-thalassemia with beta-thalassemia or hemoglobinopathy. The aim of this study was to evaluate the prevalence of alpha-thalassemia with beta-thalassemia and hemoglobinopathy co-inheritance in a considerable number of Iranian.   Methods: This descriptive study was performed on patients with abnormal hematological findings in favor of alpha-thalassemia, beta-thalassemia or beta-hemoglobinopathies. Patients with low MCV and MCH levels and high HbA2 (>3.5 and those with low MCV and MCH and normal or low HbA2 were candidate for molecular analysis for beta and alpha thalassemia respectively. Abnormal Hb electrophoresis was diagnostic criteria for molecular analysis of beta-hemoglobinopathies.   Results: Study revealed that more than half of the patients with alpha-thalassemia affected simultaneously by beta-thalassemia and about thirty percent inherited beta-hemoglobinopathies. Among patients with beta-thalassemia, HbSCd6 (A-T was the most common mutation and in alpha-thalassemic patients α 3.7 was the commonest mutation.   Conclusion: Relatively high prevalence of co-inheritance of alfa-thalassemia with beta-thalassemia and hemoglobinopathies reflect the necessity of genetic consulting and molecular analysis in diagnosis of such conditions.

  10. Betting against Beta

    DEFF Research Database (Denmark)

    Frazzini, Andrea; Heje Pedersen, Lasse

    2014-01-01

    We present a model with leverage and margin constraints that vary across investors and time. We find evidence consistent with each of the model's five central predictions: (1) Because constrained investors bid up high-beta assets, high beta is associated with low alpha, as we find empirically...

  11. GERDA - a new neutrinoless double beta experiment using 76Ge

    International Nuclear Information System (INIS)

    Meierhofer, G

    2011-01-01

    The search for neutrinoless double beta decay (0νssss) has been a very active field for the last decades. While double beta decay has been observed, 0νssss decay still waits for its experimental proof. The GErmanium Detector Array (GERDA) uses 76 Ge, an ideal candidate as it is acting as source and detector simultaneously. Germanium detectors, isotopically enriched in 76 Ge are submerged directly into an ultra pure cryo liquid, which serves as coolant and radiation shield. This concept will allow to reduce the background by up to two orders of magnitude with respect to earlier experiments. GERDA has been constructed in hall A of the underground laboratory LNGS of the INFN in Italy. The experiment started recently with a test run.

  12. The evaluation of the 0.07 mm and 3 mm dose equivalent with a portable beta spectrometer

    International Nuclear Information System (INIS)

    Hoshi, Katsuya; Yoshida, Tadayoshi; Tsujimura, Norio; Okada, Kazuhiko

    2016-01-01

    Beta spectra of various nuclide species were measured using a commercially available compact spectrometer. The shape of the spectra obtained via the spectrometer was almost similar to that of the theoretical spectra. The beta dose equivalent at any depth was obtained as a product of the measured pulse height spectra and the appropriate conversion coefficients of ICRP Publication 74. The dose rates evaluated from the spectra were comparable with the reference dose rates of standard beta calibration sources. In addition, we were able to determine the dose equivalents with a relative error of indication of 10% without the need for complicated correction. (author)

  13. Activity of beta-lactam beta-lactamase inhibitor combinations against extended spectrum beta-lactamase producing enterobacteriaceae in urinary isolates

    International Nuclear Information System (INIS)

    Iqbal, F.I.; Farooqi, B.J.

    2012-01-01

    Objective: To determine the susceptibility pattern of beta-lactam beta-lactamase inhibitor combinations against extended-spectrum beta-lactamase (ESBL) producing Enterobacteriaceae in urinary isolates. Study Design: Observational study. Place and Duration of Study: Ziauddin University Hospital, Karachi, from February to October 2008. Methodology: A total of 190 consecutive non-duplicate isolates of ESBL producing Enterobacteriaceae from urine samples of in-patients were included in the study. Urinary samples from out-patients, repeat samples and non-ESBL producing isolates were excluded. Detection of ESBL was carried out by double disk diffusion technique. Antimicrobial susceptibility testing was performed using modified Kirby Bauer's disk diffusion method according to CLSI guidelines. Statistical analysis was performed by SPSS version 10. Results: Of the 190 ESBL isolates tested, 88 cases (46.31%) were sensitive and 6 cases (3.15%) were resistant to all three combinations, the rest 96 cases (50.52%) were resistant to at least one of the combinations. Susceptibility pattern of cefoperazone/sulbactam, piperacillin/tazobactam, and amoxicillin/clavulanic acid was 95.26, 92.10, and 44.31 percent respectively. Conclusion: Cefoperazone/sulbactam exhibited the best activity against ESBL producing Enterobacteriaceae followed by piperacillin/tazobactam. Hospital antibiotic policies should be reviewed periodically to reduce the usage of extended spectrum cephalosporins and replace them with beta-lactam beta-lactamase inhibitor combinations agent for treating urinary tract infections. (author)

  14. Tables of double beta decay data

    Energy Technology Data Exchange (ETDEWEB)

    Tretyak, V.I. [AN Ukrainskoj SSR, Kiev (Ukraine)]|[Strasbourg-1 Univ., 67 (France). Centre de Recherches Nucleaires; Zdesenko, Y.G. [AN Ukrainskoj SSR, Kiev (Ukraine)

    1995-12-31

    A compilation of experimental data on double beta decay is presented. The tables contain the most stringent known experimental limits or positive results of 2{beta} transitions of 69 natural nuclides to ground and excited states of daughter nuclei for different channels (2{beta}{sup -}; 2{beta}{sup +}; {epsilon}{beta}{sup +}; 2{epsilon}) and modes (0{nu}; 2{nu}; 0{nu}M) of decay. (authors). 189 refs., 9 figs., 3 tabs.

  15. Development of dose calibrators Tandem systems and establishment of beta dosimetry in nuclear medicine

    International Nuclear Information System (INIS)

    Cecatti, Sonia Garcia Pereira

    2004-01-01

    A quality control program at Nuclear Medicine Services includes the checking of all equipment used for diagnostics and treatment, and the individual monitoring of the workers occupationally exposed to ionizing radiations. In this work the main quality control tests were performed with three dose calibrators using standard radiation sources of 57 Co, 133 Ba, 137 Cs and 60 Co. Tandem systems of dose calibrators were established and characterized using four cylindrical absorbers of different materials for an additional quality control test in Nuclear Medicine. The main utility of this new test is the possibility of impurity detection in radiopharmaceuticals, when the ratio of the measurements with different absorbers is different from that obtained at the laboratory in ideal conditions. The dosimetric characteristics of three types of CaS0 4 :Dy + Teflon pellets were studied for an appropriate choice of the material to be used for individual monitoring of workers. The thermoluminescent detectors were irradiated using beta sources of 90 Sr+ 90 Y, 204 TI, 147 Pm, 153 Sm and 32 P. A wrist badge for beta individual monitoring was developed for workers that handle beta radiopharmaceuticals in Nuclear Medicine Services. (author)

  16. Astrocytic beta 2 Adrenergic Receptor Gene Deletion Affects Memory in Aged Mice

    NARCIS (Netherlands)

    Jensen, Cathy Joanna; Demol, Frauke; Bauwens, Romy; Kooijman, Ron; Massie, Ann; Villers, Agnes; Ris, Laurence; De Keyser, Jacques

    2016-01-01

    In vitro and in vivo studies suggest that the astrocytic adrenergic signalling enhances glycogenolysis which provides energy to be transported to nearby cells and in the form of lactate. This energy source is important for motor and cognitive functioning. While it is suspected that the beta

  17. Neutrophil beta-2 microglobulin: an inflammatory mediator

    DEFF Research Database (Denmark)

    Bjerrum, O W; Nissen, Mogens Holst; Borregaard, N

    1990-01-01

    Beta-2 microglobulin (beta 2m) constitutes the light invariant chain of HLA class I antigen, and is a constituent of mobilizable compartments of neutrophils. Two forms of beta 2m exist: native beta 2m and proteolytically modified beta 2m (Des-Lys58-beta 2m), which shows alpha mobility in crossed ...

  18. Low level GAMMA0 spectrometry by beta-gamma coincidence

    International Nuclear Information System (INIS)

    Grigorescu, E.L.; Luca, A.; Razdolescu, A.C.; Ivan, C.

    1999-01-01

    Low level gamma spectrometry has a wide application, especially in environmental monitoring. Two variants, based on a beta-gamma coincidence technique, were studied. The equipment was composed of a beta detector and a Ge(Li) gamma detector (6% - relative efficiency), with the associated electronics. The gamma rays are recorded by the multichannel analyzer (4096 channels) only if the associated beta particles, which precede the gamma transitions, are registered in coincidence. Two types of beta detectors were used: plastic and liquid scintillators. In both cases, an external lead shield of 5 cm thick was used. The integral gamma background (50-1700 KeV) was reduced about 85 and 50 times, respectively. The corresponding MDA (Minimum Detectable Activity) values decreased about 1.5 and (3-7) times, respectively. The 2π sr plastic beta detector was placed on top the Ge(Li). The sample was inserted between the two detectors. The measurement time was 10 4 s. A 4π sr detector, built of the same material, was also studied, but it proved to be less advantageous because the background was reduced only 16 times; for a MDA reduction similar with that of the 2π sr variant, a longer measurement was needed (3.10 4 s). The other type of beta detector used, was a liquid scintillator. The dissolving of the samples in scintillator ensures a 4π sr measurement geometry. The vials with scintillator (10 ml volume) were placed on top the Ge(Li) and visualised by the photocathode of a phototube. This setup was surrounded by an enclosure which prevent the light penetration. The measurement time was 10 4 s. The only difficulty encountered in this low level measurement method is the accurate determination of the beta efficiency. A limitation is the possibility to measure only small mass samples. These variants are more simple and cheaper than others, previously studied. The advantage of the method is obvious when, instead of low MDA values, shorter measurement times are preferred. The

  19. Beta-decay rate and beta-delayed neutron emission probability of improved gross theory

    Science.gov (United States)

    Koura, Hiroyuki

    2014-09-01

    A theoretical study has been carried out on beta-decay rate and beta-delayed neutron emission probability. The gross theory of the beta decay is based on an idea of the sum rule of the beta-decay strength function, and has succeeded in describing beta-decay half-lives of nuclei overall nuclear mass region. The gross theory includes not only the allowed transition as the Fermi and the Gamow-Teller, but also the first-forbidden transition. In this work, some improvements are introduced as the nuclear shell correction on nuclear level densities and the nuclear deformation for nuclear strength functions, those effects were not included in the original gross theory. The shell energy and the nuclear deformation for unmeasured nuclei are adopted from the KTUY nuclear mass formula, which is based on the spherical-basis method. Considering the properties of the integrated Fermi function, we can roughly categorized energy region of excited-state of a daughter nucleus into three regions: a highly-excited energy region, which fully affect a delayed neutron probability, a middle energy region, which is estimated to contribute the decay heat, and a region neighboring the ground-state, which determines the beta-decay rate. Some results will be given in the presentation. A theoretical study has been carried out on beta-decay rate and beta-delayed neutron emission probability. The gross theory of the beta decay is based on an idea of the sum rule of the beta-decay strength function, and has succeeded in describing beta-decay half-lives of nuclei overall nuclear mass region. The gross theory includes not only the allowed transition as the Fermi and the Gamow-Teller, but also the first-forbidden transition. In this work, some improvements are introduced as the nuclear shell correction on nuclear level densities and the nuclear deformation for nuclear strength functions, those effects were not included in the original gross theory. The shell energy and the nuclear deformation for

  20. Beta measurement evaluation and upgrade

    International Nuclear Information System (INIS)

    Swinth, K.L.; Rathbun, L.A.; Roberson, P.L.; Endres, G.W.R.

    1986-01-01

    This program focuses on the resolution of problems associated with the field measurement of the beta dose component at Department of Energy (DOE) facilities. The change in DOE programs, including increased efforts in improved waste management and decontamination and decommissioning (D and D) of facilities, coupled with beta measurement problems identified at Three Mile Island has increased the need to improve beta measurements. In FY 1982, work was initiated to provide a continuing effort to identify problems associated with beta dose assessment at DOE facilities. The problems identified resulted in the development of this program. The investigation includes (1) an assessment of measurement systems now in use, (2) development of improved calibration systems and procedures, (3) application of innovative beta dosimetry concepts, (4) investigation of new instruments or concepts for monitoring and spectroscopy, and (5) development of recommendations to assure an adequate beta measurement program within DOE facilities

  1. Radiation resistant PIDECα cell using photon intermediate direct energy conversion and a 210Po source.

    Science.gov (United States)

    Weaver, Charles L; Schott, Robert J; Prelas, Mark A; Wisniewski, Denis A; Rothenberger, Jason B; Lukosi, Eric D; Oh, Kyuhak

    2018-02-01

    Radiation damage is a significant concern with both alphavoltaic and betavoltaic cells because their performance degrades, especially with high-energy - (>200keV) beta and alpha particles. Indirect excitation methods, such as the Photon Intermediate Direct Energy Conversion (PIDEC) framework, can protect the transducer from radiation. A nuclear battery using a 90 Sr beta source was constructed by the author's research group, which demonstrated the radiation resistance of a PIDEC cell driven by beta particles (PIDECβ cell). Use of alpha sources to drive nuclear batteries would appear to be much more attractive than beta sources due to higher potential power density. However, they are also subject to higher rates of radiation damage. This paper describes the successful incorporation of alpha particles into the PIDEC framework using the alpha emitter 210 Po to form a PIDECα cell. The PIDECα cell transducer was exposed to alpha particles for over one year without experiencing adverse effects from radiation damage. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Research, development and application of noncombustible Beta fiber structures. [for Apollo

    Science.gov (United States)

    Dillon, J. J.; Cobb, E. S.

    1975-01-01

    Beta fiber was selected as the primary material for flexible fibrous structures used in spacecraft and crew systems applications in the Apollo program because it was noncombustible in a 100 percent oxygen atmosphere up to 16.5 psia. It met NASA criteria for outgassing, toxicity, odor, and crew comfort, and possessed sufficient durability to last through the mission. Topics discussed include: study of spacecraft applications; design of Beta fiber textile structures to meet the requirements; selection of surface treatments (finishes, coatings, and printing systems) to impart the required durability and special functional use to the textile structures; development of sewing and fabrication techniques; and testing and evaluation programs, and development of production sources.

  3. Interactions between an alpha-helix and a beta-sheet. Energetics of alpha/beta packing in proteins.

    Science.gov (United States)

    Chou, K C; Némethy, G; Rumsey, S; Tuttle, R W; Scheraga, H A

    1985-12-05

    Conformational energy computations have been carried out to determine the favorable ways of packing a right-handed alpha-helix on a right-twisted antiparallel or parallel beta-sheet. Co-ordinate transformations have been developed to relate the position and orientation of the alpha-helix to the beta-sheet. The packing was investigated for a CH3CO-(L-Ala)16-NHCH3 alpha-helix interacting with five-stranded beta-sheets composed of CH3CO-(L-Val)6-NHCH3 chains. All internal and external variables for both the alpha-helix and the beta-sheet were allowed to change during energy minimization. Four distinct classes of low-energy packing arrangements were found for the alpha-helix interacting with both the parallel and the anti-parallel beta-sheet. The classes differ in the orientation of the axis of the alpha-helix relative to the direction of the strands of the right-twisted beta-sheet. In the class with the most favorable arrangement, the alpha-helix is oriented along the strands of the beta-sheet, as a result of attractive non-bonded side-chain-side-chain interactions along the entire length of the alpha-helix. A class with nearly perpendicular orientation of the helix axis to the strands is also of low energy, because it allows similarly extensive attractive interactions. In the other two classes, the helix is oriented diagonally relative to the strands of the beta-sheet. In one of them, it interacts with the convex surface near the middle of the saddle-shaped twisted beta-sheet. In the other, it is oriented along the concave diagonal of the beta-sheet and, therefore, it interacts only with the corner regions of the sheet, so that this packing is energetically less favorable. The packing arrangements involving an antiparallel and a parallel beta-sheet are generally similar, although the antiparallel beta-sheet has been found to be more flexible. The major features of 163 observed alpha/beta packing arrangements in 37 proteins are accounted for in terms of the computed

  4. Kinematic shifts of beta -delayed particles as a probe of beta - nu angular correlations

    CERN Document Server

    Clifford, E T H; Evans, H C; Fästermann, T; Hagberg, E; Hardy, J C; Jackson, K P; Koslowsky, V T; Schmeing, H; Schrewe, U J

    1981-01-01

    Beta-delayed particles undergo a kinematic shift in energy due to recoil motion of the daughter nucleus following beta decay. A careful measurement of this energy shift can be used to establish the ratio of vector to axial vector components in beta transitions. Alpha-beta coincidence data for the beta-delayed alpha decay of /sup 20/Na have been obtained. Component ratios for 6 transitions including the superallowed branch are found. Limits on charge dependent mixing with the analogue state are deduced for 5 states in /sup 20/Ne*. For the superallowed branch the axial vector component is found; the polar vector component is deduced and establishes a value for the vector weak coupling constant of G/sub V/=(1.355+or-0.036)*10/sup -49/ erg cm /sup 3/. (13 refs).

  5. RESEARCH OF BETA AS ADEQUATE RISK MEASURE-IS BETA STILL ALIVE?

    Directory of Open Access Journals (Sweden)

    Ante Perković

    2011-02-01

    Full Text Available The capital asset pricing model (CAPM is one of the most important models in financial economics and it has a long history of theoretical and empirical investigations. The main underlying concept of the CAPM model is that assets with a high risk (high beta should earn a higher return than assets with a low risk (low beta and vice versa. The implication which can be drawn out of this is that all assets with a beta above zero bear some risk and therefore their expected return is above the return of the risk-free rate. In this research observation on monthly stock prices on Croatian stock market from January 1st 2005 until December 31st 2009 is used to form our sample. CROBEX index is used as proxy of the market portfolio. The results demonstrate that beta can not be trusted in making investment decisions and rejects the validity of the whole CAPM model on Croatian stock market.

  6. Natural radioactivity in groundwater sources in Ireland

    Energy Technology Data Exchange (ETDEWEB)

    Currivan, L.; Dowdall, A.; Mcginnity, P.; Ciara, M. [Radiological Protection Institute of Ireland (Ireland); Craig, M. [Environmental Protection Agency (Ireland)

    2014-07-01

    The Radiological Protection Institute of Ireland (RPII) in collaboration with the Irish Environmental Protection Agency (EPA) undertook a national survey of radioactivity in groundwater sources for compliance with parameters set out in the European Communities Drinking Water Directive. The Directive outlines the minimum requirements for the quality of drinking water and water intended for human consumption. Over two hundred samples were screened for radioactivity. Where indicated, analysis for individual radionuclide activity was undertaken and the radiation dose arising calculated. Furthermore, samples were analysed for radon concentration. This survey is the first comprehensive national survey of radioactivity in groundwater sources in Ireland. Approximately 18 per cent of drinking water in Ireland originates from groundwater and springs with the remainder from surface water. Between 2007 and 2011, water samples from a representative network of groundwater sources were analysed and assessed for compliance with the radioactivity parameters set out in the Drinking Water Directive. The assessment was carried out using the methodology for screening drinking water set out by the WHO. For practical purposes the WHO recommended screening levels for drinking water below which no further action is required of 100 mBq/l for gross alpha activity and 1000 mBq/l for gross beta activity were applied. Of the 203 groundwater sources screened for gross alpha and gross beta all met the gross beta activity criteria of less than 1000 mBq/l and 175 supplies had gross alpha activity concentrations of less than 100 mBq/l. For these sources no further analysis was required. The remaining 28 sources required further (radionuclide-specific) analysis from an alpha activity perspective. Results on ranges and distributions of radionuclide concentrations in groundwater as well as ingestion doses estimated for consumers of these water supplies will be presented. Document available in abstract

  7. Beta decay heat following U-235, U-238 and Pu-239 neutron fission

    Science.gov (United States)

    Li, Shengjie

    1997-09-01

    This is an experimental study of beta-particle decay heat from 235U, 239Pu and 238U aggregate fission products over delay times 0.4-40,000 seconds. The experimental results below 2s for 235U and 239Pu, and below 20s for 238U, are the first such results reported. The experiments were conducted at the UMASS Lowell 5.5-MV Van de Graaff accelerator and 1-MW swimming-pool research reactor. Thermalized neutrons from the 7Li(p,n)7Be reaction induced fission in 238U and 239Pu, and fast neutrons produced in the reactor initiated fission in 238U. A helium-jet/tape-transport system rapidly transferred fission fragments from a fission chamber to a low background counting area. Delay times after fission were selected by varying the tape speed or the position of the spray point relative to the beta spectrometer that employed a thin-scintillator-disk gating technique to separate beta-particles from accompanying gamma-rays. Beta and gamma sources were both used in energy calibration. Based on low-energy(energies 0-10 MeV. Measured beta spectra were unfolded for their energy distributions by the program FERD, and then compared to other measurements and summation calculations based on ENDF/B-VI fission-product data performed on the LANL Cray computer. Measurements of the beta activity as a function of decay time furnished a relative normalization. Results for the beta decay heat are presented and compared with other experimental data and the summation calculations.

  8. Regulation of the friction coefficient of articular cartilage by TGF-beta1 and IL-1beta.

    Science.gov (United States)

    DuRaine, Grayson; Neu, Corey P; Chan, Stephanie M T; Komvopoulos, Kyriakos; June, Ronald K; Reddi, A Hari

    2009-02-01

    Articular cartilage functions to provide a low-friction surface for joint movement for many decades of life. Superficial zone protein (SZP) is a glycoprotein secreted by chondrocytes in the superficial layer of articular cartilage that contributes to effective boundary lubrication. In both cell and explant cultures, TGF-beta1 and IL-1beta have been demonstrated to, respectively, upregulate and downregulate SZP protein levels. It was hypothesized that the friction coefficient of articular cartilage could also be modulated by these cytokines through SZP regulation. The friction coefficient between cartilage explants (both untreated and treated with TGF-beta1 or IL-1beta) and a smooth glass surface due to sliding in the boundary lubrication regime was measured with a pin-on-disk tribometer. SZP was quantified using an enzyme-linked immunosorbant assay and localized by immunohistochemistry. Both TGF-beta1 and IL-1beta treatments resulted in the decrease of the friction coefficient of articular cartilage in a location- and time-dependent manner. Changes in the friction coefficient due to the TGF-beta1 treatment corresponded to increased depth of SZP staining within the superficial zone, while friction coefficient changes due to the IL-1beta treatment were independent of SZP depth of staining. However, the changes induced by the IL-1beta treatment corresponded to changes in surface roughness, determined from the analysis of surface images obtained with an atomic force microscope. These findings demonstrate that the low friction of articular cartilage can be modified by TGF-beta1 and IL-1beta treatment and that the friction coefficient depends on multiple factors, including SZP localization and surface roughness.

  9. A semiconductor beta ray spectrometer

    International Nuclear Information System (INIS)

    Bom, V.R.

    1987-01-01

    Measurement of energy spectra of beta particles emitted from nuclei in beta-decay processes provides information concerning the mass difference of these nuclei between initial and final state. Moreover, experimental beta spectra yield information on the feeding of the levels in the daughter nucleus. Such data are valuable in the construction and checking of the level schemes. This thesis describes the design, construction, testing and usage of a detector for the accurate measurement of the mentioned spectra. In ch. 2 the design and construction of the beta spectrometer, which uses a hyper-pure germanium crystal for energy determination, is described. A simple wire chamber is used to discriminate beta particles from gamma radiation. Disadvantages arise from the large amounts of scattered beta particles deforming the continua. A method is described to minimize the scattering. In ch. 3 some theoretical aspects of data analysis are described and the results of Monte-Carlo simulations of the summation of annihilation radiation are compared with experiments. Ch. 4 comprises the results of the measurements of the beta decay energies of 103-108 In. 87 refs.; 34 figs.; 7 tabs

  10. Influence of food acidulants and antioxidant spices on the bioaccessibility of beta-carotene from selected vegetables.

    Science.gov (United States)

    Veda, Supriya; Platel, Kalpana; Srinivasan, Krishnapura

    2008-09-24

    Four common food acidulants--amchur, lime, tamarind, and kokum--and two antioxidant spices--turmeric and onion--were examined for their influence on the bioaccessibility of beta-carotene from two fleshy and two leafy vegetables. Amchur and lime generally enhanced the bioaccessibility of beta-carotene from these test vegetables in many instances. Such an improved bioaccessibility was evident in both raw and heat-processed vegetables. The effect of lime juice was generally more pronounced than that of amchur. Turmeric significantly enhanced the bioaccessibility of beta-carotene from all of the vegetables tested, especially when heat-processed. Onion enhanced the bioaccessibility of beta-carotene from pressure-cooked carrot and amaranth leaf and from open-pan-boiled pumpkin and fenugreek leaf. Lime juice and the antioxidant spices turmeric and onion minimized the loss of beta-carotene during heat processing of the vegetables. In the case of antioxidant spices, improved bioaccessibility of beta-carotene from heat-processed vegetables is attributable to their role in minimizing the loss of this provitamin. Lime juice, which enhanced the bioaccessibility of this provitamin from both raw and heat-processed vegetables, probably exerted this effect by some other mechanism in addition to minimizing the loss of beta-carotene. Thus, the presence of food acidulants (lime juice/amchur) and antioxidant spices (turmeric/onion) proved to be advantageous in the context of deriving maximum beta-carotene from the vegetable sources.

  11. Single fiber beta detector for stereotactic biopsy and intraoperative lumpectomy of breast cancer

    International Nuclear Information System (INIS)

    Atac, M.; Nalcioglu, O.; Roeck, W.W.

    1996-10-01

    We have developed an intraoperative probe for use in early detection of breast cancer and aiding lumpectomy. The probe consists of a small plastic scintillator, 0.8mm dia and 3mm long, coupled to a single clear optical-fiber strand, and solid state photomultiplier. Due to the small size of the probe, it can be placed inside of a small gauge biopsy needle. The scintillator is very efficient in detecting betas and positrons while being very in efficient to energetic gammas due to small size and low density. High quantum efficiency, 80%, and high gain obtainable, solid state photomultiplier makes the probe very low noise device in detecting beta particles. Intrinsic resolution of the probe is expected to be around 1 mm. Preliminary results using beta sources and a rat bearing R320 adenocarcinoma tumor were very successful

  12. Synthesis of the {beta}-phenethyl-mercaptan ({sup 35}S); Synthese du {beta}-phenethylmercaptan ({sup 35}S)

    Energy Technology Data Exchange (ETDEWEB)

    Wolff, R [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1957-07-01

    {beta}-phenethyl-mercaptan ({sup 35}S) has been synthesized by action of elementary radioactive sulphur ({sup 35}S) on {beta}-phenethyl-magnesium-bromide, with a 90 per cent yield. (author) [French] Le {beta}-phenethylmercaptan ({sup 35}S) a ete synthetise par action du soufre radioactif elementaire ({sup 35}S) sur le bromure de {beta}-phenethylmagnesium, avec un rendement de 90 pour cent. (auteur)

  13. Precision Study of the $\\beta$-decay of $^{62}$Ga

    CERN Multimedia

    2002-01-01

    It is proposed to perform a precision study of the $\\beta$-decay of $\\,^{62}$Ga taking advantage of recent developments of the ISOLDE Laser Ion Source. The goal is to eventually extend the high-precision knowledge of superallowed $\\beta$-decays beyond the nine decays that presently are used for extracting the V$_{ud}$ quark mixing matrix element of the CKM matrix. The scientific motivations are the current deviation of more than 2$\\sigma$ of the unitary condition of this matrix, which could be an indication of non-standard-model physics, and a test of the theoretical corrections applied to the experimental data. The experiment will utilise the Total Absorption $\\gamma$-ray (TAG) spectrometer in order to determine weak branchings to excited states in $^{62}$Zn and the ISOLDE spectroscopy station to perform half-life measurements and detailed spectroscopy of this nucleus.

  14. Protocol for characterization and intercomparison of alpha beta measurement between detectors, surface barrier and proportional sealed in fixed and field laboratories; Protocolo para caracterização e intercomparação da medição alfa beta entre detectores, barreira de superfície e proporcional selado em laboratórios fixo e de campo

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, M.S.; Cardoso, D.O.; Guimarães Junior, W.J., E-mail: soarescarvalho.mariana@gmail.com [Instituto Militar de Engenharia (IME), Rio de Janeiro, RJ (Brazil); Santos, A.D.; Amorim, A.S. de; Balthar, M.C.V.; Oliveira, L.S.R., E-mail: domingosoliveiralvr71@gmail.com [Instituto de Defesa Química Biológica Radiológica Nuclear (IDQBRN), Rio de Janeiro, RJ (Brazil); Arbach, M.N. [Instituto de Radioproteção e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    In this work, alpha and beta particle measurements were performed with the purpose of intercomparison the results from two different equipment, namely: a sealed proportional (NT-200) and a surface barrier detector (iMatic). Both equipment are already installed in the Institute of Chemical Biological Radiological Defense (IDQBRN), located in the Technological Center of the Army (CTEx). In situations that result in accidental or intentional exposure or contamination to alpha beta-emitting materials, such equipment is used in the analysis of samples from the above-mentioned situations. The NT-200 is initially used for analysis of the field samples, in case there is a need for a better evaluation or a proof of results these measurements will be carried out with iMatic. By exposing the equipment to the same emitting source and under the same conditions of use, the alpha efficiency from an {sup 241}Am source is 16.4 and 38% for the beta from the {sup 90}Sr source of 13.8% and 28%, respectively, for the NT-200 and iMatic. By exposing the equipment to the same emitting source and under the same conditions of use, the efficiency for alpha coming from an {sup 241}Am source are 16.4 and 38%, for beta from the {sup 90}Sr source are 13.8% and 28%, respectively, for the NT-200 and iMatic.

  15. Beta Instability and Stochastic Market Weights

    OpenAIRE

    David H. Goldenberg

    1985-01-01

    An argument is given for individual firm beta instability based upon the stochastic character of the market weights defining the market portfolio and the constancy of its beta. This argument is generalized to market weighted portfolios and the form of the stochastic process generating betas is linked to that of the market return process. The implications of this analysis for adequacy of models of beta nonstationarity and estimation of betas are considered in light of the available empirical e...

  16. The effects of lower than conventional doses of oral nadolol on relative beta 1/beta 2-adrenoceptor blockade.

    Science.gov (United States)

    Wheeldon, N M; McDevitt, D G; Lipworth, B J

    1994-08-01

    1. The aim of the present study was to evaluate the relative beta 1/beta 2 antagonist selectivity of the beta-adrenoceptor blocker nadolol, in lower than conventional clinical doses. 2. Eight normal volunteers received single oral doses of either placebo (PL), nadolol 5 mg (N5), 20 mg (N20) or 80 mg (N80) in a single-blind, randomised crossover design. beta 1-adrenoceptor antagonism was assessed by attenuation of exercise tachycardia, and beta 2-adrenoceptor blockade by effects on salbutamol-induced chronotropic, hypokalaemic and finger tremor responses. The relative percentage attenuation of beta 2 and beta 1-mediated responses was calculated and expressed as beta 2:beta 1 selectivity ratios. 3. Nadolol produced dose-related reductions in exercise tachycardia in keeping with increasing beta 1-adrenoceptor blockade; mean % reduction (95% CI) compared with placebo: N5 10.7 (6.6 to 14.8), N20 21.4 (17.3 to 25.4), N80 38.9 (34.8 to 42.9). However, even the lowest dose of nadolol (5 mg) produced almost complete blunting of beta 2-mediated effects and significantly increase exercise hyperkalaemia; peak exercise hyperkalaemia (mmol l-1) (means and 95% CI): PL 4.88 (4.68 to 5.07), N5 5.36 (5.17 to 5.55), N20 5.48 (5.28 to 5.67), N80 5.42 (5.22 to 5.61). beta 2:beta 1 selectivity ratios significantly increased as the dose of nadolol was reduced. 4. These data suggest that whereas in the clinical dose range nadolol behaves as a non-selective beta-adrenoceptor antagonist, as the dose is reduced this drug demonstrates an increasing degree of selectivity for the beta 2-adrenoceptor.(ABSTRACT TRUNCATED AT 250 WORDS)

  17. Energy Calibration of a Silicon Detector Using Pure Beta-Emitters; Calibracion Energetica de un Detector de Silicio Mediante Emisores Beta Puros

    Energy Technology Data Exchange (ETDEWEB)

    Borras, C; Arcos, J M. los

    1992-07-01

    Energy calibration of SI detectors used in electron spectroscopy 13 commonly performed with conversion electron sources or monoenergetic electrons beams, which are preferred against beta emitters due to the problems arising from their continuous spectra. This paper presents a simple calibration procedure for a PIP-type silicon detector, using 14C, 147Pm, 99{sup T}c and 45Ca sources, that is based on the correspondence between the average channel observed in the experimental spectrum and the mean energy evaluated from the theoretical Fermi distribution for each nuclide. First, a method for evaluating the average channel in the experimental spectrum distorted by the electronic noise is described and its uncertainty estimated. Then, the channel-energy relation ship is established by least squares fitting modified to account for uncertainties in both variables.The calibration has been successfully verified with 147Pm and '09cd sources, showing discrepaneles not greater than 2.5%, within the uncertainties due to the detector resolution and the sources features. (Author)

  18. Energy Calibration of a Silicon Detector Using Pure Beta-Emitters; Calibracion Energetica de un Detector de Silicio Mediante Emisores Beta Puros

    Energy Technology Data Exchange (ETDEWEB)

    Borras, C.; Arcos, J. M. los

    1992-07-01

    Energy calibration of SI detectors used in electron spectroscopy 13 commonly performed with conversion electron sources or monoenergetic electrons beams, which are preferred against beta emitters due to the problems arising from their continuous spectra. This paper presents a simple calibration procedure for a PIP-type silicon detector, using 14C, 147Pm, 99{sup T}c and 45Ca sources, that is based on the correspondence between the average channel observed in the experimental spectrum and the mean energy evaluated from the theoretical Fermi distribution for each nuclide. First, a method for evaluating the average channel in the experimental spectrum distorted by the electronic noise is described and its uncertainty estimated. Then, the channel-energy relation ship is established by least squares fitting modified to account for uncertainties in both variables.The calibration has been successfully verified with 147Pm and '09cd sources, showing discrepaneles not greater than 2.5%, within the uncertainties due to the detector resolution and the sources features. (Author)

  19. Studies of insulin secretory responses and of arachidonic acid incorporation into phospholipids of stably transfected insulinoma cells that overexpress group VIA phospholipase A2 (iPLA2beta ) indicate a signaling rather than a housekeeping role for iPLA2beta.

    Science.gov (United States)

    Ma, Z; Ramanadham, S; Wohltmann, M; Bohrer, A; Hsu, F F; Turk, J

    2001-04-20

    A cytosolic 84-kDa group VIA phospholipase A(2) (iPLA(2)beta) that does not require Ca(2+) for catalysis has been cloned from several sources, including rat and human pancreatic islet beta-cells and murine P388D1 cells. Many potential iPLA(2)beta functions have been proposed, including a signaling role in beta-cell insulin secretion and a role in generating lysophosphatidylcholine acceptors for arachidonic acid incorporation into P388D1 cell phosphatidylcholine (PC). Proposals for iPLA(2)beta function rest in part on effects of inhibiting iPLA(2)beta activity with a bromoenol lactone (BEL) suicide substrate, but BEL also inhibits phosphatidate phosphohydrolase-1 and a group VIB phospholipase A(2). Manipulation of iPLA(2)beta expression by molecular biologic means is an alternative approach to study iPLA(2)beta functions, and we have used a retroviral construct containing iPLA(2)beta cDNA to prepare two INS-1 insulinoma cell clonal lines that stably overexpress iPLA(2)beta. Compared with parental INS-1 cells or cells transfected with empty vector, both iPLA(2)beta-overexpressing lines exhibit amplified insulin secretory responses to glucose and cAMP-elevating agents, and BEL substantially attenuates stimulated secretion. Electrospray ionization mass spectrometric analyses of arachidonic acid incorporation into INS-1 cell PC indicate that neither overexpression nor inhibition of iPLA(2)beta affects the rate or extent of this process in INS-1 cells. Immunocytofluorescence studies with antibodies directed against iPLA(2)beta indicate that cAMP-elevating agents increase perinuclear fluorescence in INS-1 cells, suggesting that iPLA(2)beta associates with nuclei. These studies are more consistent with a signaling than with a housekeeping role for iPLA(2)beta in insulin-secreting beta-cells.

  20. Energy response of imaging plates to radiation beams from standard beta sources, ortho-voltage and cobalt-60 units and linear accelerators

    Science.gov (United States)

    Gonzalez, Albin Leonel

    The response to different types of radiation beams of commercial imaging plates used for diagnostic computed radiography has been investigated in this work. Imaging plates are designed with a phosphor layer which after been irradiated; information is stored in the form of photostimulable luminescence (PSL) centers. Initial measurements of the dose distribution of a radioactive stent with the imaging plates showed similar results to those with radiochromic films, but with much shorter exposure time due to their higher sensitivity. In order to investigate further their response, the imaging plates were irradiated with calibrated beams from: standard beta sources, orthovoltage and Co-60 units and therapy linear accelerator. Initially it was found that the energy to create the storage centers (generation efficiency) when irradiated with the three standard beta sources (225 keV to 2.28 MeV) was the same. For the rest of the calibrated beams an in house reader system was built in order to perform the bleaching of the plates with a He-Ne laser (632.8 nm) and to measure the absolute number of the emitted PSL photons (storage centers produced). Bleaching curves were then obtained for different exposure times for each beam. From the graph of the calculated area under the bleaching curves (total number of storage center) versus the absorbed dose to the phosphor layer it was possible to calculate the energy to create the storage centers (generation efficiency) for photon and electron beams. The dose to the phosphor layer was calculated in the case of the electron beams following a scaling procedure, while in the case of the photon beams Monte Carlo simulations were performed. For the photons beams the measurement of the generation efficiency energy of 126 +/- 8% eV per PSL storage center, coincide with measurements using a different approach (˜148 eV) by previous investigators. The generation efficiency for the electron beam was 807 +/- 3% eV, no reference was found in the

  1. Atualizações sobre beta-hidroxi-beta-metilbutirato: suplementação e efeitos sobre o catabolismo de proteínas New findings on beta-hydroxy-beta-methylbutyirate: supplementation and effects on the protein catabolism

    Directory of Open Access Journals (Sweden)

    Everson Araújo Nunes

    2008-04-01

    Full Text Available O beta-hidroxi-beta-metilbutirato, metabólito do aminoácido leucina, vem sendo utilizado como suplemento alimentar, em situações específicas, com o intuito de aumentar ou manter a massa isenta de gordura. Os relatos dos efeitos do beta-hidroxi-beta-metilbutirato em estudos recentes fizeram crescer as expectativas sobre sua utilização em casos patológicos. Também foram demonstrados melhores resultados, quando da sua ingestão, no treinamento de força em indivíduos iniciantes e em idosos. Em humanos o beta-hidroxi-beta-metilbutirato tem sido usado como agente anti-catabólico, e em modelos animais foi demonstrado ser eficaz em inibir a atividade de vias proteolíticas em células musculares de indivíduos caquéticos in vitro e in vivo. Os mecanismos participantes desses processos envolvem: a inibição da atividade do sistema ubiquitina proteossoma ATP-dependente, a inibição de vias de sinalização com participação da proteína quinase C-alfa e a diminuição da concentração citoplasmática do fator nuclear - kappa B livre, eventos relacionados ao decréscimo da proteólise em células musculares.The leucine metabolite beta-hydroxy-beta-methylbutyrate has been used as a nutritional supplement in specific situations to prevent losing or to increase lean mass. Recent studies showed interesting results of beta-hydroxy-beta-methylbutyrate supplementation in certain disease states. Better results have also been demonstrated when it is taken by starters or old individuals doing strength training. In humans, beta-hydroxy-beta-methylbutyrate has been used as an anticatabolic agent and in animal models it has been demonstrated to be effective in inhibiting the activity of the proteolytic pathways in muscle cells of extremely weak individuals in vivo and in vitro. The mechanisms that participate in this process involve: inhibition of the ATP-ubiquitin-proteasome pathway, inhibition of the signalization pathways involving protein kinase C

  2. High beta tokamaks

    International Nuclear Information System (INIS)

    Dory, R.A.; Berger, D.P.; Charlton, L.A.; Hogan, J.T.; Munro, J.K.; Nelson, D.B.; Peng, Y.K.M.; Sigmar, D.J.; Strickler, D.J.

    1978-01-01

    MHD equilibrium, stability, and transport calculations are made to study the accessibility and behavior of ''high beta'' tokamak plasmas in the range β approximately 5 to 15 percent. For next generation devices, beta values of at least 8 percent appear to be accessible and stable if there is a conducting surface nearby

  3. Characterization of a beta-glycosidase highly active on disaccharides and of a beta-galactosidase from Tenebrio molitor midgut lumen.

    Science.gov (United States)

    Ferreira, Alexandre H P; Terra, Walter R; Ferreira, Clélia

    2003-02-01

    The midgut of the yellow mealworm, Tenebrio molitor L. (Coleoptera: Tenebrionidae) larvae has four beta-glycosidases. The properties of two of these enzymes (betaGly1 and betaGly2) have been described elsewhere. In this paper, the characterization of the other two glycosidases (betaGly3 and betaGly4) is described. BetaGly3 has one active site, hydrolyzes disaccharides, cellodextrins, synthetic substrates and beta-glucosides produced by plants. The enzyme is inhibited by amygdalin, cellotriose, cellotetraose and cellopentaose in high concentrations, probably due to transglycosylation. betaGly3 hydrolyzes beta 1,4-glycosidic linkages with a catalytic rate independent of the substrate polymerization degree (k(int)) of 11.9 s(-1). Its active site is formed by four subsites, where subsites +1 and -1 bind glucose residues with higher affinity than subsite +2. The main role of betaGly3 seems to be disaccharide hydrolysis. BetaGly4 is a beta-galactosidase, since it has highest activity against beta-galactosides. It can also hydrolyze fucosides, but not glucosides, and has Triton X-100 as a non-essential activator (K(a)=15 microM, pH 4.5). betaGly4 has two active sites that can hydrolyze p-nitrophenyl beta-galactoside (NPbetaGal). The one hydrolyzing NPbetaGal with more efficiency is also active against methylumbellipheryl beta-D-galactoside and lactose. The other active site hydrolyzes NPbetaFucoside and binds NPbetaGal weakly. BetaGly4 hydrolyzes hydrophobic substrates with high catalytical efficiency and is able to bind octyl-beta-thiogalactoside in its active site with high affinity. The betaGly4 physiological role is supposed to be the hydrolysis of galactolipids that are found in membranes from vegetal tissues. As the enzyme has a hydrophobic site where Triton X-100 can bind, it might be activated by membrane lipids, thus becoming fully active only at the surface of cell membranes.

  4. Non-stochastic effects of different energy beta emitters on pig and mouse skin

    International Nuclear Information System (INIS)

    Peel, D.M.; Hopewell, J.W.; Hansen, L.S.; Coggle, J.E.; Charles, M.W.; Wells, J.

    1982-01-01

    In this collaborative study skin areas of various sizes were irradiated with different energy beta emitters. In the post-irradiation period fields were examined for erythema, desquamation, ulceration and dermal necrosis. The aim of the study is to determine the threshold doses for the different biological reactions as a function of the energy of the radiation and the size of skin field irradiated. At St. Bartholomew's Hospital and Oxford the irradiation of mouse and pig skin was carried out using strontium-90 and thulium-170 sources. In addition, mice were irradiated with thallium-204, a slightly lower energy beta emitter than thulium. (author)

  5. Radioisotope Power Sources; Sources d'energie utilisant les radiobotopes; Radioizotopnye istochniki ehnergii; Fuentes radio isotopicas de energia

    Energy Technology Data Exchange (ETDEWEB)

    Culwell, J. P. [USAEC, Washington, D.C (United States)

    1963-11-15

    The radioisotope power programme of the US Atomic Energy Commission has brought forth a whole new technology of the use of radioisotopes as energy sources in electric power generators. Radioisotope power systems are particularly suited for remote applications where long-lived, compact, reliable power is needed. Able to perform satisfactorily under extreme environmental conditions of temperature, sunlight and electromagnetic radiations, these ''atomic batteries'' are attractive power sources for remote data collecting devices, monitoring systems, satellites and other space missions. Radioisotopes used as fuels generally are either alpha or beta emitters. Alpha emitters are the preferable fuels but are more expensive and less available than beta fuels and are generally reserved for space applications. Beta fuels separated from reactor fission wastes are being used exclusively in land and sea applications at the present. It can be expected, however, that beta emitters such as stiontium-90 eventually will be used in space. Development work is being carried out on generators which will use mixed fission products as fuel. This fuel will be less expensive than the pure radioisotopes since the costs of isotope separation and purification are eliminated. Prototype thermoelectric generators, fuelled with strontium-90 and caesium-137, are now in operation or being developed for use in weather stations, marine navigation aids and deep sea monitoring devices. A plutonium-238 thermoelectric generator is in orbit operating as electric power source in a US Navy TRANSIT satellite. Generators are under development for use on US National Aeronautics and Space Administration missions. The large quantities of radioactivity involved in radioisotope power sources require that special attention be given to safety aspects of the units. Rigid safety requirements have been established and extensive tests have been conducted to insure that these systems can be employed without creating undue

  6. Microbial flora analysis for the degradation of beta-cypermethrin.

    Science.gov (United States)

    Qi, Zhang; Wei, Zhang

    2017-03-01

    In the Xinjiang region of Eurasia, sustained long-term and continuous cropping of cotton over a wide expanse of land is practiced, which requires application of high levels of pyrethroid and other classes of pesticides-resulting in high levels of pesticide residues in the soil. In this study, soil samples were collected from areas of long-term continuous cotton crops with the aim of obtaining microbial resources applicable for remediation of pyrethroid pesticide contamination suitable for the soil type and climate of that area. Soil samples were first used to culture microbial flora capable of degrading beta-cypermethrin using an enrichment culture method. Structural changes and ultimate microbial floral composition during enrichment were analyzed by high-throughput sequencing. Four strains capable of degrading beta-cypermethrin were isolated and preliminarily classified. Finally, comparative rates and speeds of degradation of beta-cypermethrin between relevant microbial flora and single strains were determined. After continuous subculture for 3 weeks, soil sample microbial flora formed a new type of microbial flora by rapid succession, which showed stable growth by utilizing beta-cypermethrin as the sole carbon source (GXzq). This microbial flora mainly consisted of Pseudomonas, Hyphomicrobium, Dokdonella, and Methyloversatilis. Analysis of the microbial flora also permitted separation of four additional strains; i.e., GXZQ4, GXZQ6, GXZQ7, and GXZQ13 that, respectively, belonged to Streptomyces, Enterobacter, Streptomyces, and Pseudomonas. Under culture conditions of 37 °C and 180 rpm, the degradation rate of beta-cypermethrin by GXzq was as high as 89.84% within 96 h, which exceeded that achieved by the single strains GXZQ4, GXZQ6, GXZQ7, and GXZQ13 and their derived microbial flora GXh.

  7. Dynamic returns of beta arbitrage

    OpenAIRE

    Nascimento, Mafalda

    2017-01-01

    This thesis studies the patterns of the abnormal returns of the beta strategy. The topic can be helpful for professional investors, who intend to achieve a better performance in their portfolios. Following the methodology of Lou, Polk, & Huang (2016), the COBAR measure is computed in order to determine the levels of beta arbitrage in the market in each point in time. It is argued that beta arbitrage activity can have impact on the returns of the beta strategy. In fact, it is demonstrated that...

  8. Dosimetry of β extensive sources

    International Nuclear Information System (INIS)

    Rojas C, E.L.; Lallena R, A.M.

    2002-01-01

    In this work, we have been studied, making use of the Penelope Monte Carlo simulation code, the dosimetry of β extensive sources in situations of spherical geometry including interfaces. These configurations are of interest in the treatment of the called cranealfaringyomes of some synovia leisure of knee and other problems of interest in medical physics. Therefore, its application can be extended toward problems of another areas with similar geometric situation and beta sources. (Author)

  9. Equine endometrial fibrosis correlates with 11beta-HSD2, TGF-beta1 and ACE activities.

    Science.gov (United States)

    Ganjam, V K; Evans, T J

    2006-03-27

    Endometrial periglandular fibrosis (EPF) contributes to embryonic and fetal loss in mares. Equine EPF correlates inversely with conception and successful gestation. In the modified Kenney endometrial biopsy classification system, EPF categories I, IIA, IIB, and III correspond to minimal, mild, moderate, and severe fibrosis (+/-inflammation), respectively. Paraffin sections of biopsy specimens were stained with H&E, and picrosirius red (specific for fibrillar collagens types I and III), to determine %EPCVF. Endometrial ACE-binding activity, TGF-beta1 and 11beta-HSD2 activities were also measured. Ultrastructural changes in EPF categories IIB and III endometria strongly suggested myofibroblastic transformation. ACE-binding activity was highest in EPF category IIB; however, endometrial TGF-beta1 and 11beta-HSD2 activities were significantly correlated to the severity of EPF (P<0.05). We conclude that, locally generated angiotensin II initiates the expression of TGF-beta1 resulting in myofibroblastic transformation. 11Beta-HSD2 in concert appears to modulate the severity of endometrial fibrosis.

  10. The GERDA Neutrinoless Double Beta-Decay Experiment

    International Nuclear Information System (INIS)

    Majorovits, Bela A.

    2007-01-01

    Neutrinoless double beta (0νββ)-decay is the key process to gain understanding of the nature of neutrinos. The GErmanium Detector Array (GERDA) is designed to search for 0νββ-decay of the isotope 76 Ge. Germanium crystals enriched in 76 Ge, acting as source and detector simultaneously, will be submerged directly into an ultra pure cooling medium that also serves as a radiation shield. This concept will allow for a reduction of the background by up to two orders of magnitudes with respect to earlier experiments

  11. [{sup 125}I]{beta}-CIT-FE and [{sup 125}I]{beta}-CIT-FP are superior to [{sup 125}I]{beta}-CIT for dopamine transporter visualization: Autoradiographic evaluation in the human brain

    Energy Technology Data Exchange (ETDEWEB)

    Guenther, Ilonka; Hall, Haakan; Halldin, Christer; Swahn, Carl-Gunnar; Farde, Lars; Sedvall, Goeran

    1997-10-01

    The binding of the three dopamine transporter radioligands ([{sup 125}I]{beta}-CIT, [{sup 125}I]{beta}-CIT-FE, and [{sup 125}I]{beta}-CIT-FP) was studied using whole-hemisphere autoradiography on postmortem human brains. The autoradiograms revealed an intense and homogeneous labeling of the nucleus caudatus and putamen but also to varying extent to serotonergic and noradrenergic transporters of neocortex and thalamus. The order of specificity estimated (striatum over neocortex ratios) was {beta}-CIT-FP > {beta}-CIT-FE >> {beta}-CIT, suggesting that {beta}-CIT-FE and {beta}-CIT-FP should be preferred for in vivo studies of the dopamine transporter in the human brain.

  12. The P1approximation in the transport of beta rays

    International Nuclear Information System (INIS)

    Legarda, F.; Idoeta, R.; Herranz, M.

    1994-01-01

    A validation test for the p1 approximation to the linear transport of electrons in planar geometry has been performed. The p1 approximation is shown to be a good option for the description of the transport of beta rays with endpoint energies between 400kev and 3.5Mev through aluminium foils . This approximation together with the use of only elastic interactions of electrons with atoms has found good agreement with experimental results . A calculation has been made of the fraction of transmitted electrons through foils, solving the transport equation for planar geometry in the p1 approximation and assuming that only elastic scattering processes take place. The boundary condition at the entrance of the foil was a collimated beta source, while at the end of the foil has been adopted a vaccum boundary condition.Sources considered are those for which experimental and calculated spectrum shapes are known to agree. The calculated fractional transmission through different absorber thicknesses is found to have an exponential shape . Besides this fact the attenuation coefficients found ,when compared with those empirically obtained, agree to within 5%. 1 fig.; 4 refs. (author)

  13. National pattern for the realization of the unit of the dose speed absorbed in air for beta radiation. (Method: Ionometer, cavity of Bragg-Gray implemented in an extrapolation chamber with electrodes of variable separation, exposed to a field of beta radiation of 90Sr/90Y)

    International Nuclear Information System (INIS)

    Alvarez R, M. T.; Morales P, J. R.

    2001-01-01

    From the year of 1987 the Department of Metrology of the ININ, in their Secondary Laboratory of Calibration Dosimetric, has a patron group of sources of radiation beta and an extrapolation chamber of electrodes of variable separation.Their objective is to carry out of the unit of the dose speed absorbed in air for radiation beta. It uses the ionometric method, cavity Bragg-Gray in the extrapolation chamber with which it counts. The services that offers are: i) it Calibration : Radioactive Fuentes of radiation beta, isotopes: 90 Sr/ 90 Y; Ophthalmic applicators 9 0 S r/ 90 Y; Instruments for detection of beta radiation with to the radiological protection: Ionization chambers, Geiger-Muller, etc.; Personal Dosemeters. ii) Irradiation with beta radiation of materials to the investigation. (Author)

  14. A comparison of heart function and arrhythmia in clinically asymptomatic patients with beta thalassemia intermedia and beta thalassemia major.

    Science.gov (United States)

    Amoozgar, Hamid; Zeighami, Samaneh; Haghpanah, Sezaneh; Karimi, Mehran

    2017-01-01

    The goal of this study was to compare heart function and arrhythmia in clinically asymptomatic patients with beta thalassemia intermedia and beta thalassemia major. In this cross-sectional study, 60 patients with beta thalassemia major and 60 patients with beta thalassemia intermedia who had clinically no symptoms of arrhythmia and clinically normal heart function were evaluated using 24-hour ambulatory electrocardiogram monitoring and echocardiography. For data analysis SPSS ver.20 software was used. A P-value of less than 0.05 was considered statistically significant. The mean age of the beta thalassemia intermedia patients was 24.18 ± 7.9 years and the mean age in beta thalassemia major was 24.38 ± 7.7 years (P>0.05). Premature atrial contractions (PACs) were observed in 14 (23.3%) patients with beta thalassemia intermedia and in 22 (36.6%) beta thalassemia major patients. Premature ventricular contractions (PVCs) were detected in 8 (13.3%) patients in the beta thalassemia intermediate group and 16 (26.6) patients in the beta thalassemia major group, respectively. The left ventricular diastolic dimension, end-diastolic volume, and stroke volume were significantly higher in beta thalassemia intermedia group (Pintermedia group. Both atrial and ventricular arrhythmias were more common in the beta thalassemia major group. Higher end-diastolic volume and stroke volume were detected in the beta thalassemia intermedia group. Pulmonary acceleration time was lower in the beta thalassemia intermedia group, which can be an indicator of higher pulmonary pressure.

  15. Integration of BETA with Eclipse

    DEFF Research Database (Denmark)

    Andersen, Peter; Madsen, Ole Lehrmann; Enevoldsen, Mads Brøgger

    2004-01-01

    This paper presents language interoperability issues appearing in order to implement support for the BETA language in the Java-based Eclipse integrated development environment. One of the challenges is to implement plug-ins in BETA and be able to load them in Eclipse. In order to do this, some fo...... it is possible to implement plug-ins in BETA and even inherit from Java classes. In the paper the two approaches are described together with part of the mapping from BETA to Java class files. http://www.sciencedirect.com/science/journal/15710661...

  16. Methodology development for dosimetry of 90Sr + 90Y beta therapy applicators

    International Nuclear Information System (INIS)

    Coelho, T.S.; Yoriyaz, H.; Fernandes, M.A.R.

    2009-01-01

    The 9 0Sr+ 9 0Y applicators, used in beta therapy for prevention of keloids and pterigio, are imported and its dosimetric features are only illustrated by the manufacturers. The exhaustive routine of the medical physicists in the clinic do not make possible the accomplishment of procedures for the confirmation of these parameters. This work presents a methodology development for dosimetry in two 9 0Sr+ 9 0Y beta therapy applicators of the Amersham brand. The Monte Carlo code MCNP 4 C was used for the simulation of the percentage depth dose curves. The experimental measurements of the radiation attenuation had been done with a mini-extrapolation chamber. The results of the experimental measures had been compared with the simulated values. Both percentage deep dose curves, the theoretical and the experimental ones, had presented similar behavior, which may validate the use of the MCNP 4 C for these simulations, strengthening the usage of this method at procedures of dosimetry of these beta radiation sources. (author)

  17. Thymosin beta 4 and thymosin beta 10 expression in hepatocellular carcinoma

    Directory of Open Access Journals (Sweden)

    W. Theunissen

    2014-03-01

    Full Text Available Thymosin beta 4 (Tβ4 and thymosin beta 10 (Tβ10 are two members of the beta-thymosin family involved in many cellular processes such as cellular motility, angiogenesis, inflammation, cell survival and wound healing. Recently, a role for beta-thymosins has been proposed in the process of carcinogenesis as both peptides were detected in several types of cancer. The aim of the present study was to investigate the expression pattern of Tβ4 and Tβ10 in hepatocellular carcinoma (HCC. To this end, the expression pattern of both peptides was analyzed in liver samples obtained from 23 subjects diagnosed with HCC. Routinely formalin-fixed and paraffin-embedded liver samples were immunostained by indirect immunohistochemistry with polyclonal antibodies to Tβ4 and Tβ10. Immunoreactivity for Tβ4 and Tβ10 was detected in the liver parenchyma of the surrounding tumor area. Both peptides showed an increase in granular reactivity from the periportal to the periterminal hepatocytes. Regarding HCC, Tβ4 reactivity was detected in 7/23 cases (30% and Tβ10 reactivity in 22/23 (97% cases analyzed, adding HCC to human cancers that express these beta-thymosins. Intriguing finding was seen looking at the reactivity of both peptides in tumor cells infiltrating the surrounding liver. Where Tβ10 showed a strong homogeneous expression, was Tβ4 completely absent in cells undergoing stromal invasion. The current study shows expression of both beta-thymosins in HCC with marked differences in their degree of expression and frequency of immunoreactivity. The higher incidence of Tβ10 expression and its higher reactivity in tumor cells involved in stromal invasion indicate a possible major role for Tβ10 in HCC progression.

  18. Development of the Dutch primary standard for beta-emitting brachytherapy sources

    International Nuclear Information System (INIS)

    Marel, J. an der; Dijk, E. van

    2002-01-01

    The application of β-radiation emitting radioactive sources in medicine is rapidly expanding. An important new application is the use of β-radiation emitting radioactive sources in endovascular brachytherapy to avoid restenosis. Another well-known application is the use of the ophthalmic applicator (flat or concave surface source) for the treatment of tumors in the eye. Dose and dose distributions are very important characteristics of brachytherapy sources. The absorbed dose in the treated tissue should be known accurately to assure a good quality of the treatment and to develop new treatment methods and source configurations. At the Nederland s Meetinstituut (NMi) a project is going on for the development of a primary standard for betadosimetry. With this standard, dose and dose distributions of β-sources as used in brachytherapy can be measured in terms of absorbed dose to water. The primary standard is based on an extrapolation chamber. The extrapolation chamber will become part of a quality assurance system in Dutch hospitals for endovascular brachytherapy sources. The quality assurance system will further consist of transfer standards like well-type ionisation chambers, plastic scintillator systems and radiochromic film dosimetry. Apart from the endovascular sources the extrapolation chamber will be used to characterize ophthalmic applicators

  19. In vitro effects of beta-lactams combined with beta-lactamase inhibitors against methicillin-resistant Staphylococcus aureus.

    Science.gov (United States)

    Kobayashi, S; Arai, S; Hayashi, S; Sakaguchi, T

    1989-01-01

    The effects of combinations of beta-lactams with two beta-lactamase inhibitors, sulbactam and clavulanic acid, were determined in vitro against 22 clinical isolates of methicillin-resistant Staphylococcus aureus. Combinations of cefpirome, cefotaxime, and cefazolin with sulbactam (10 micrograms/ml) showed synergistic effects against more than 70% of the strains. Combinations of methicillin and penicillin G with sulbactam also showed synergistic effects against 50 and 68% of the strains, respectively, while cefotiam, moxalactam, flomoxef, and cefmetazole in combination with sulbactam showed such effects against only 40% or fewer. Clavulanic acid was synergistic only when combined with penicillin G, the effect probably being due to the beta-lactamase inhibition by the inhibitor. Sulbactam did not improve the antimicrobial activities of the beta-lactams against methicillin-susceptible S. aureus strains. At 42 degrees C the MICs of cefotaxime, methicillin, and flomoxef alone were markedly decreased from the values at 35 degrees C, and no synergy between these beta-lactams and sulbactam appeared. The resistance to penicillin G was not inhibited by incubation at 42 degrees C, and combinations of penicillin G with sulbactam and clavulanic acid showed synergy. The amounts of beta-lactamase produced were not related to the decreases in the MICs of the beta-lactams, except for penicillin G combined with sulbactam. Clavulanic acid showed slightly stronger beta-lactamase-inhibiting activity than sulbactam did. These results suggest that the synergy between sulbactam and the beta-lactams, except for penicillin G, may not be due to beta-lactamase inhibition but to suppression of the methicillin-resistant S. aureus-specific resistance based on other factors. PMID:2786369

  20. Alpha and beta detection and spectrometry

    International Nuclear Information System (INIS)

    Saro, S.

    1984-01-01

    The theory of alpha and beta radioactive decay, the interaction of alpha and beta particles with matter, and their detection and spectrometry are dealt with in seven chapters: 1. Alpha transformation of atomic nuclei; 2. Basic properties of detectors and statistics of detection; 3. Alpha detectors and spectrometers; 4. Applications of alpha detection and spectrometry; 5. Beta transformation of atomic nuclei; 6. Beta particle detectors and spectrometers; 7. Detection of low energy beta particles. Chapter 8 is devoted to sampling and preparation of samples for radiometry. (E.F.)

  1. The interaction of beta 2-microglobulin (beta 2m) with mouse class I major histocompatibility antigens and its ability to support peptide binding. A comparison of human and mouse beta 2m

    DEFF Research Database (Denmark)

    Pedersen, L O; Stryhn, A; Holter, T L

    1995-01-01

    of class I molecules are involved in peptide binding, whereas most of class I molecules are involved in beta 2m binding. We propose that mouse beta 2m interacts with the minor peptide binding (i.e. the "empty") fraction with a lower affinity than human beta 2m does, whereas mouse and human beta 2m interact......The function of major histocompatibility complex (MHC) class I molecules is to sample peptides derived from intracellular proteins and to present these peptides to CD8+ cytotoxic T lymphocytes. In this paper, biochemical assays addressing MHC class I binding of both peptide and beta 2-microglobulin...... (beta 2m) have been used to examine the assembly of the trimolecular MHC class I/beta 2m/peptide complex. Recombinant human beta 2m and mouse beta 2ma have been generated to compare the binding of the two beta 2m to mouse class I. It is frequently assumed that human beta 2m binds to mouse class I heavy...

  2. Misleading Betas: An Educational Example

    Science.gov (United States)

    Chong, James; Halcoussis, Dennis; Phillips, G. Michael

    2012-01-01

    The dual-beta model is a generalization of the CAPM model. In the dual-beta model, separate beta estimates are provided for up-market and down-market days. This paper uses the historical "Anscombe quartet" results which illustrated how very different datasets can produce the same regression coefficients to motivate a discussion of the…

  3. Beta-glucosidase variants and polynucleotides encoding same

    Science.gov (United States)

    Wogulis, Mark; Harris, Paul; Osborn, David

    2017-06-27

    The present invention relates to beta-glucosidase variants, e.g. beta-glucosidase variants of a parent Family GH3A beta-glucosidase from Aspergillus fumigatus. The present invention also relates to polynucleotides encoding the beta-glucosidase variants; nucleic acid constructs, vectors, and host cells comprising the polynucleotides; and methods of using the beta-glucosidase variants.

  4. Characterization of the inclusion complex ropivacaine: {beta}-cyclodextrin; Caracterizacao do complexo de inclusso ropivacaina: {beta}-ciclodextrina

    Energy Technology Data Exchange (ETDEWEB)

    Fraceto, Leonardo Fernandes [Universidade Estadual Paulista Julio de Mesquita Filho, Sorocaba, SP (Brazil). Dept. de Engenharia Ambiental]. E-mail: leonardo@sorocaba.unesp.br; Goncalves, Marcos Moises [Universidade de Sorocaba, SP (Brazil); Moraes, Carolina Morales; Araujo, Daniele Ribeiro de; Zanella, Luciana; Paula, Eneida de [Universidade Estadual de Campinas (UNICAMP), Campinas, SP (Brazil). Inst. de Biologia. Dept. de Bioquimica; Pertinhez, Thelma de Aguiar [Universidade de Parma (Italy). Dept. de Medicina Experimental

    2007-09-15

    Ropivacaine (RVC) is a widely used local anesthetic. The complexation of RVC with {beta}-cyclodextrin ({beta}-CD) is of great interest for the development of more efficient local anesthetic formulations. The present work focuses on the characterization of the RVC:{beta}-CD complex by nuclear magnetic resonance (NMR). The stoichiometry of the complex is 1:2 RVC:{beta}-CD. DOSY-NMR shows that the association constant is 55.5 M{sup -1}. Longitudinal relaxation time results show that RVC changes its mobility in the presence of {beta}-CD. This study is focused on the physicochemical characterization of inclusion complexes that are potentials options for pain treatment. (author)

  5. Monte Carlo simulation of {beta}-{gamma} coincidence system using plastic scintillators in 4{pi} geometry

    Energy Technology Data Exchange (ETDEWEB)

    Dias, M.S. [Instituto de Pesquisas Energeticas e Nucleares: IPEN-CNEN/SP, Av. Prof. Lineu Prestes 2242, 05508-000 Sao Paulo, SP (Brazil)], E-mail: msdias@ipen.br; Piuvezam-Filho, H. [Instituto de Pesquisas Energeticas e Nucleares: IPEN-CNEN/SP, Av. Prof. Lineu Prestes 2242, 05508-000 Sao Paulo, SP (Brazil); Baccarelli, A.M. [Departamento de Fisica-PUC/SP-Rua Marques de Paranagua 111, 01303-050 Sao Paulo, SP (Brazil); Takeda, M.N. [Universidade Santo Amaro, UNISA-Rua Prof. Eneas da Siqueira Neto 340, 04829-300 Sao Paulo, SP (Brazil); Koskinas, M.F. [Instituto de Pesquisas Energeticas e Nucleares: IPEN-CNEN/SP, Av. Prof. Lineu Prestes 2242, 05508-000 Sao Paulo, SP (Brazil)

    2007-09-21

    A modified version of a Monte Carlo code called Esquema, developed at the Nuclear Metrology Laboratory in IPEN, Sao Paulo, Brazil, has been applied for simulating a 4{pi}{beta}(PS)-{gamma} coincidence system designed for primary radionuclide standardisation. This system consists of a plastic scintillator in 4{pi} geometry, for alpha or electron detection, coupled to a NaI(Tl) counter for gamma-ray detection. The response curves for monoenergetic electrons and photons have been calculated previously by Penelope code and applied as input data to code Esquema. The latter code simulates all the disintegration processes, from the precursor nucleus to the ground state of the daughter radionuclide. As a result, the curve between the observed disintegration rate as a function of the beta efficiency parameter can be simulated. A least-squares fit between the experimental activity values and the Monte Carlo calculation provided the actual radioactive source activity, without need of conventional extrapolation procedures. Application of this methodology to {sup 60}Co and {sup 133}Ba radioactive sources is presented and showed results in good agreement with a conventional proportional counter 4{pi}{beta}(PC)-{gamma} coincidence system.

  6. Activities of beta-lactam antibiotics against Escherichia coli strains producing extended-spectrum beta-lactamases.

    Science.gov (United States)

    Jacoby, G A; Carreras, I

    1990-01-01

    Seven extended-spectrum beta-lactamases related to TEM and four enzymes derived from SHV-1 were transferred to a common Escherichia coli host so that the activity of a variety of beta-lactams could be tested in a uniform genetic environment. For most derivatives, penicillinase activity was 10% or less than that of strains making TEM-1, TEM-2, or SHV-1 beta-lactamase, suggesting that reduced catalytic efficiency accompanied the broader substrate spectrum. Despite this deficit, resistance to aztreonam, carumonam, cefdinir, cefepime, cefixime, cefmenoxime, cefotaxime, cefotiam, cefpirome, cefpodoxime, ceftazidime, ceftibuten, ceftizoxime, ceftriaxone, cefuroxime, and E1040 was enhanced. For strains producing TEM-type enzymes, however, MICs of carumonam, cefepime, cefmenoxime, cefotiam, cefpirome, and ceftibuten were 8 micrograms/ml or less. Susceptibilities of cefmetazole, cefotetan, cefoxitin, flomoxef, imipenem, meropenem, moxalactam, temocillin, FCE 22101, and Sch 34343 were unaffected. FCE 22101, imipenem, meropenem, and Sch 34343 were inhibitory for all strains at 1 microgram/ml or less. In E. coli an OmpF- porin mutation in combination with an extended-spectrum beta-lactamase enhanced resistance to many of these agents, but generally by only fourfold. Hyperproduction of chromosomal AmpC beta-lactamase increased resistance to 7-alpha-methoxy beta-lactams but not that to temocillin. When tested at 8 micrograms/ml, clavulanate was more potent than sulbactam or tazobactam in overcoming resistance to ampicillin, while cefoperazone-sulbactam was more active than ticarcillin-clavulanate or piperacillin-tazobactam, especially against TEM-type extended-spectrum beta-lactamases. PMID:2193623

  7. TGF-{beta}-stimulated aberrant expression of class III {beta}-tubulin via the ERK signaling pathway in cultured retinal pigment epithelial cells

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Eun Jee [Department of Ophthalmology, National Health Insurance Corporation Ilsan Hospital, Gyeonggi-do (Korea, Republic of); Chun, Ji Na; Jung, Sun-Ah [Konyang University Myunggok Medical Research Institute, Kim' s Eye Hospital, Konyang University College of Medicine, Seoul (Korea, Republic of); Cho, Jin Won [Department of Biology, Yonsei University, 134 Shinchon-dong, Seodaemun-gu, Seoul 120-749 (Korea, Republic of); Lee, Joon H., E-mail: joonhlee@konyang.ac.kr [Konyang University Myunggok Medical Research Institute, Kim' s Eye Hospital, Konyang University College of Medicine, Seoul (Korea, Republic of)

    2011-11-18

    Highlights: Black-Right-Pointing-Pointer TGF-{beta} induces aberrant expression of {beta}III in RPE cells via the ERK pathway. Black-Right-Pointing-Pointer TGF-{beta} increases O-GlcNAc modification of {beta}III in RPE cells. Black-Right-Pointing-Pointer Mature RPE cells have the capacity to express a neuron-associated gene by TGF-{beta}. -- Abstract: The class III {beta}-tubulin isotype ({beta}{sub III}) is expressed exclusively by neurons within the normal human retina and is not present in normal retinal pigment epithelial (RPE) cells in situ or in the early phase of primary cultures. However, aberrant expression of class III {beta}-tubulin has been observed in passaged RPE cells and RPE cells with dedifferentiated morphology in pathologic epiretinal membranes from idiopathic macular pucker, proliferative vitreoretinopathy (PVR) and proliferative diabetic retinopathy (PDR). Transforming growth factor-{beta} (TGF-{beta}) has been implicated in dedifferentiation of RPE cells and has a critical role in the development of proliferative vitreoretinal diseases. Here, we investigated the potential effects of TGF-{beta} on the aberrant expression of class III {beta}-tubulin and the intracellular signaling pathway mediating these changes. TGF-{beta}-induced aberrant expression and O-linked-{beta}-N-acetylglucosamine (O-GlcNac) modification of class III {beta}-tubulin in cultured RPE cells as determined using Western blotting, RT-PCR and immunocytochemistry. TGF-{beta} also stimulated phosphorylation of ERK. TGF-{beta}-induced aberrant expression of class III {beta}-tubulin was significantly reduced by pretreatment with U0126, an inhibitor of ERK phosphorylation. Our findings indicate that TGF-{beta} stimulated aberrant expression of class III {beta}-tubulin via activation of the ERK signaling pathway. These data demonstrate that mature RPE cells have the capacity to express a neuron-associated gene in response to TGF-{beta} stimulation and provide useful information

  8. Milk Intolerance, Beta-Casein and Lactose.

    Science.gov (United States)

    Pal, Sebely; Woodford, Keith; Kukuljan, Sonja; Ho, Suleen

    2015-08-31

    True lactose intolerance (symptoms stemming from lactose malabsorption) is less common than is widely perceived, and should be viewed as just one potential cause of cows' milk intolerance. There is increasing evidence that A1 beta-casein, a protein produced by a major proportion of European-origin cattle but not purebred Asian or African cattle, is also associated with cows' milk intolerance. In humans, digestion of bovine A1 beta-casein, but not the alternative A2 beta-casein, releases beta-casomorphin-7, which activates μ-opioid receptors expressed throughout the gastrointestinal tract and body. Studies in rodents show that milk containing A1 beta-casein significantly increases gastrointestinal transit time, production of dipeptidyl peptidase-4 and the inflammatory marker myeloperoxidase compared with milk containing A2 beta-casein. Co-administration of the opioid receptor antagonist naloxone blocks the myeloperoxidase and gastrointestinal motility effects, indicating opioid signaling pathway involvement. In humans, a double-blind, randomized cross-over study showed that participants consuming A1 beta-casein type cows' milk experienced statistically significantly higher Bristol stool values compared with those receiving A2 beta-casein milk. Additionally, a statistically significant positive association between abdominal pain and stool consistency was observed when participants consumed the A1 but not the A2 diet. Further studies of the role of A1 beta-casein in milk intolerance are needed.

  9. Milk Intolerance, Beta-Casein and Lactose

    Directory of Open Access Journals (Sweden)

    Sebely Pal

    2015-08-01

    Full Text Available True lactose intolerance (symptoms stemming from lactose malabsorption is less common than is widely perceived, and should be viewed as just one potential cause of cows’ milk intolerance. There is increasing evidence that A1 beta-casein, a protein produced by a major proportion of European-origin cattle but not purebred Asian or African cattle, is also associated with cows’ milk intolerance. In humans, digestion of bovine A1 beta-casein, but not the alternative A2 beta-casein, releases beta-casomorphin-7, which activates μ-opioid receptors expressed throughout the gastrointestinal tract and body. Studies in rodents show that milk containing A1 beta-casein significantly increases gastrointestinal transit time, production of dipeptidyl peptidase-4 and the inflammatory marker myeloperoxidase compared with milk containing A2 beta-casein. Co-administration of the opioid receptor antagonist naloxone blocks the myeloperoxidase and gastrointestinal motility effects, indicating opioid signaling pathway involvement. In humans, a double-blind, randomized cross-over study showed that participants consuming A1 beta-casein type cows’ milk experienced statistically significantly higher Bristol stool values compared with those receiving A2 beta-casein milk. Additionally, a statistically significant positive association between abdominal pain and stool consistency was observed when participants consumed the A1 but not the A2 diet. Further studies of the role of A1 beta-casein in milk intolerance are needed.

  10. TL glow curve analysis of UV, beta and gamma induced limestone collected from Amarnath holy cave

    Directory of Open Access Journals (Sweden)

    Vikas Dubey

    2015-01-01

    Full Text Available The paper reports themoluminescence glow curve analysis of UV (ultraviolet, β (beta and γ (gamma induced limestone collected from Amarnath holy cave. The collected natural sample was characterized by X-ray diffraction (XRD technique and crystallite size calculated by Scherer's formula. Surface morphology and particle size was calculated by transmission electron microscopy (TEM study. Effect of annealing temperature on collected lime stone examined by TL glow curve study. The limestone was irradiated by UV radiation (254 nm source and the TL glow curve recorded for different UV exposure time. For beta irradiation Sr90 source was used and is shows intense peak at 256 °C with a shoulder peak at higher temperature range. For gamma radiation Co60 source and TL glow curve recorded for different doses of gamma. The kinetic parameters calculation was performed for different glow curve by computerized glow curve deconvolution (CGCD technique. The chemical composition of natural limestone was analyzed by energy dispersive X-ray spectroscopy (EDXS.

  11. National pattern for the realization of the unit of the dose speed absorbed in air for beta radiation. (Method: Ionometer, cavity of Bragg-Gray implemented in an extrapolation chamber with electrodes of variable separation, exposed to a field of beta radiation of {sup 90}Sr/{sup 90}Y); Patron Nacional para la realizacion de la unidad de la rapidez de dosis absorbida en aire para radiacion beta. (Metodo: Ionometrico, cavidad de Bragg-Gray implementada en una camara de extrapolacion con electrodos de separacion variable, expuesta a un campo de radiacion beta de {sup 90}Sr/{sup 90}Y)

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez R, M T; Morales P, J R [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    2001-01-15

    From the year of 1987 the Department of Metrology of the ININ, in their Secondary Laboratory of Calibration Dosimetric, has a patron group of sources of radiation beta and an extrapolation chamber of electrodes of variable separation.Their objective is to carry out of the unit of the dose speed absorbed in air for radiation beta. It uses the ionometric method, cavity Bragg-Gray in the extrapolation chamber with which it counts. The services that offers are: i) it Calibration : Radioactive Fuentes of radiation beta, isotopes: {sup 90}Sr/{sup 90}Y; Ophthalmic applicators {sup 9}0{sup S}r/{sup 90}Y; Instruments for detection of beta radiation with to the radiological protection: Ionization chambers, Geiger-Muller, etc.; Personal Dosemeters. ii) Irradiation with beta radiation of materials to the investigation. (Author)

  12. Cross-class resistance to non-beta-lactam antimicrobials in extended-spectrum beta-lactamase-producing Klebsiella pneumoniae.

    Science.gov (United States)

    Procop, Gary W; Tuohy, Marion J; Wilson, Deborah A; Williams, Delisa; Hadziyannis, Emilia; Hall, Gerri S

    2003-08-01

    Extended spectrum beta-lactamases are modified beta-lactamase enzymes that impart resistance to third-generation cephalosporins and make all beta-lactam antibiotics and cephalosporins useless for therapy. We compared the antimicrobial susceptibility profiles of extended-spectrum beta-lactamase (ESBL)-producing and non-ESBL-producing isolates of Klebsiella pneumoniae. The ESBL producers had significantly diminished susceptibility compared with the non-ESBL producers for gentamicin (P < .001), tobramycin (P < .001), amikacin (P < .005), trimethoprim-sulfamethoxazole (P < .01), ciprofloxacin (P < .001), and nitrofurantoin (P < .001). All isolates were susceptible to imipenem. ESBL-producing K pneumoniae may also be resistant to non-beta-lactam antibiotics. Therefore, susceptibility testing of these isolates is critical for guiding therapy.

  13. Shape-coexistence and shape-evolution studies for bismuth isotopes by insource laser spectroscopy and $\\beta$-delayed fission in $^{188}$Bi

    CERN Multimedia

    The proposal aims at the two main goals: \\\\ \\\\1) the studies of shape-coexistence and shape-evolution phenomena in the long chain of bismuth isotopes (Z=83) by in-source laser spectroscopy measurements of isotopic shifts (IS) and hyperfine structures (hfs), and \\\\ 2) $\\beta$-delayed fission ($\\beta$DF) of two isomeric states in $^{188}$Bi. \\\\ \\\\Isomer-selective $\\beta$DF studies for $^{188m1, 188m2}$Bi isomers will enable us for the first time to investigate the spin-dependence of the $\\beta$DF process and to check theoretical predictions of asymmetrical fission fragment mass-distribution in this region of nuclei. The measurements will be performed with the well-proven Windmill and MR-TOF MS/Penning Trap techniques.

  14. Optimized computational method for determining the beta dose distribution using a multiple-element thermoluminescent dosimeter system

    International Nuclear Information System (INIS)

    Shen, L.; Levine, S.H.; Catchen, G.L.

    1987-01-01

    This paper describes an optimization method for determining the beta dose distribution in tissue, and it describes the associated testing and verification. The method uses electron transport theory and optimization techniques to analyze the responses of a three-element thermoluminescent dosimeter (TLD) system. Specifically, the method determines the effective beta energy distribution incident on the dosimeter system, and thus the system performs as a beta spectrometer. Electron transport theory provides the mathematical model for performing the optimization calculation. In this calculation, parameters are determined that produce calculated doses for each of the chip/absorber components in the three-element TLD system. The resulting optimized parameters describe an effective incident beta distribution. This method can be used to determine the beta dose specifically at 7 mg X cm-2 or at any depth of interest. The doses at 7 mg X cm-2 in tissue determined by this method are compared to those experimentally determined using an extrapolation chamber. For a great variety of pure beta sources having different incident beta energy distributions, good agreement is found. The results are also compared to those produced by a commonly used empirical algorithm. Although the optimization method produces somewhat better results, the advantage of the optimization method is that its performance is not sensitive to the specific method of calibration

  15. Beta-1-Selective Beta-Blockers and Cognitive Functions in Patients With Coronary Artery Disease: A Cross-Sectional Study.

    Science.gov (United States)

    Burkauskas, Julius; Noreikaite, Aurelija; Bunevicius, Adomas; Brozaitiene, Julija; Neverauskas, Julius; Mickuviene, Narseta; Bunevicius, Robertas

    2016-01-01

    The association between current beta-1-selective beta-blocker use and cognitive function was evaluated in 722 patients with coronary artery disease without dementia. Beta-1-selective beta-blocker use was associated with worse incidental learning independently of sociodemographic characteristics, clinical coronary artery disease severity, and depression/anxiety.

  16. Patterns of alpha, beta and gamma diversity of the herpetofauna in Mexico’s Pacific lowlands and adjacent interior valleys

    Directory of Open Access Journals (Sweden)

    García, A.

    2007-12-01

    Full Text Available The latitudinal distribution patterns of alpha, beta and gamma diversity of reptiles, amphibians and herpetofauna were analyzed using individual binary models of potential distribution for 301 species predicted by ecological modelling for a grid of 9,932 quadrants of ~25 km2 each. We arranged quadrants in 312 latitudinal bands in which alpha, beta and gamma values were determined. Latitudinal trends of all scales of diversity were similar in all groups. Alpha and gamma responded inversely to latitude whereas beta showed a high latitudinal fluctuation due to the high number of endemic species. Alpha and gamma showed a strong correlation in all groups. Beta diversity is an important component of the herpetofauna distribution patterns as a continuous source of species diversity throughout the region.

  17. A comparison of the activities of three beta-galactosidases in aqueous-organic solvent mixtures

    NARCIS (Netherlands)

    Yoon, JH; Mckenzie, D

    2005-01-01

    The hydrolytic activities of beta-galactosidases from three different sources have been determined in various 50% (v/v) organic solvent-buffer mixtures with a view to finding solvent systems of reduced water content suitable for the synthesis of glycosides and oligosaccharides. K. fragilis

  18. Superconducting tests of beta = 0.1 and beta = 0.2 resonators

    International Nuclear Information System (INIS)

    Storm, D.W.; Amsbaugh, J.F.; Corcoran, D.T.; Howe, M.A.

    1985-01-01

    Several low beta (0.10) and two high beta (0.21) lead plated copper quarter wave resonators were cooled down, multipactor conditioned, tested, helium conditioned, and retested. The choice of the quarter wave resonator and of the lead plated copper technology is discussed. The fabrication is described and techniques for conditioning the resonators are presented. Performances are presented. 5 refs., 4 figs

  19. A mini X-ray generator as an alternative to a 90Sr/90Y beta source in luminescence dating

    DEFF Research Database (Denmark)

    Andersen, C.E.; Bøtter-Jensen, L.; Murray, A.S.

    2003-01-01

    We have carried out an investigation to test whether mini X-ray generators are a suitable alternative to radioactive sources in luminescence dating. The study has mainly been motivated by the need for high dose rates (similar to 1 Gy/s) to make dating of older samples using regeneration protocols...... with a sample of thermally sensitized sedimentary quartz suggest that we can use beta and X-ray irradiation interchangeably from the point of view of construction of growth curves by the single-aliquot regenerative-dose protocol. (C) 2003 Elsevier Science Ltd. All rights reserved....

  20. Elaboration of supports for beta emitting sources (with vyns)

    International Nuclear Information System (INIS)

    Cortes P, A.; Torre O, J. De la; Tejera R, A.; Becerril V, A.; Bribiesca S, L.

    1990-04-01

    The Laboratory of Radioactive patterns account with a 4 πβ-γ coincidence system of recent acquisition with which absolute measures of radioactive activity with uncertainties of the order of 0.1% can be made. Since the coincidence method for the activity measure consists on detecting to the particle and the photon corresponding to oneself nuclear disintegration, it is necessary to elaborate special radioactive sources on thin supports, in order to allowing the maximum possible fluence of β particles (∼ 100%). This work a technique for the elaboration of these sources and for the measure of the thickness of the walls of the support is presented. (Author)

  1. Measurement of the beta-neutrino correlation in laser trapped 21Na

    Energy Technology Data Exchange (ETDEWEB)

    Scielzo, Nicholas David [Univ. of California, Berkeley, CA (United States)

    2003-01-01

    Trapped radioactive atoms are an appealing source for precise measurements of the beta-neutrino correlation coefficient, a, since the momentum of the neutrino can be inferred from the detection of the unperturbed low-energy recoil daughter nucleus. Sodium-21 is produced on-line at the 88'' cyclotron at Lawrence Berkeley National Laboratory, and 8e5 atoms have been maintained in a magneto-optical trap. A static electric field draws daughter Neon-21 ions to a microchannel plate detector and betas are detected in coincidence with a plastic scintillator beta detector. The Neon-21 time-of-flight distribution determines the beta neutrino correlation coefficient, a. The resulting charge-state distribution is compared to a simple model based on the sudden approximation which suggests a small but important contribution from nuclear recoil-induced ionization. A larger than expected fraction of the daughters are detected in positive charge-states, but no dependence on either the beta or recoil nucleus energy was observed. We find a = 0.5243 plus or minus 0.0092, which is in 3.6 sigma disagreement with the Standard Model prediction of a = 0.559 plus or minus 0.003. Aside from a deviation from the Standard Model, a possible explanation for the discrepancy is that the branching ratio to the first excited state is in error.

  2. Realisation of a {beta} spectrometer solenoidal and a double {beta} spectrometer at coincidence; Realisation d'un spectrometre {beta} solenoidal et d'un double spectrometre {beta} a coincidence

    Energy Technology Data Exchange (ETDEWEB)

    Moreau, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1955-06-15

    The two spectrometers have been achieved to tackle numerous problems of nuclear spectrometry. They possess different fields of application that complete themselves. The solenoidal spectrometer permits the determination of the energy limits of {beta} spectra and of their shape; it also permits the determination of the coefficients of internal conversion and reports {alpha}{sub K} / {alpha}{sub L} and it is especially efficient for the accurate energy levels of the {gamma} rays by photoelectric effect. The double coincidence spectrometer has been conceived to get a good efficiency in coincidence: indeed, the sum of the solid angles used for the {beta} and {gamma} emission is rather little lower to 4{pi} steradians. To get this efficiency, one should have sacrificed a little the resolution that is lower to the one obtained with the solenoidal spectrometer for a same brightness. Each of the elements of the double spectrometer can also be adapted to the study of angular correlations {beta}{gamma} and e{sup -}{gamma}. In this use, it is superior to the thin magnetic lens used up to here. The double spectrometer also permits the survey of the coincidences e{sup -}e{sup -}, e{sup -}{beta} of a equivalent way to a double lens; it can also be consider some adaptation for the survey of the angular correlations e{sup -}e{sup -}, e{sup -}{beta}. Finally, we applied the methods by simple spectrometry and by coincidence spectrometry, to the study of the radiances of the following radioelements: {sup 76}As (26 h), {sup 122}Sb (2,8 j), {sup 124}Sb (60 j), {sup 125}Sb (2,7 years). (M.B.) [French] Les deux spectrometres qui ont ete realises permettent d'aborder un grand nombre de problemes de spectrometrie nucleaire. Ils possedent des champs d'application tres differents qui se completent. Le spectrometre solenoidal permet la determination des energies limites des spectres {beta} et de leur forme; il permet aussi la determination des coefficients de conversion interne et des rapports

  3. Requirement of radiochemical recovery determination for gross alpha and gross beta estimation in drinking water

    International Nuclear Information System (INIS)

    Raveendran, Nanda; Rao, D.D.; Hegde, A.G.

    2010-01-01

    Presence of radionuclides in drinking water which emits Alpha and Beta particles are the potential sources of internal exposure in drinking water. Gross alpha and gross beta determination in drinking water and packaged drinking water (PDW) as per BIS (Bureau of Indian standards) standards is discussed here. The methods have been tested to account for losses in the radiochemical procedures using radionuclides such as 137 Cs, 90 Sr, 226 Ra, 239 Pu, 243 Am, 232 U. The methods have also been validated in an IAEA proficiency test conducted during 2009. Monitoring of gross alpha and gross beta activity observed in drinking water/packaged drinking water from various states of India were within the limits set by BIS. Average radiochemical recoveries of 84% and 63% were obtained for gross α and gross β respectively. (author)

  4. Beta strength distributions in neutron-deficient Kr and Sr isotopes using a total absorption spectrometer

    CERN Document Server

    Maréchal, F

    2003-01-01

    Far from the line of stability, beta -decay studies are often a primary source of information on nuclear structure. The measured beta -strength distribution for a given decay can be used to verify the accuracy of our theoretical description of the parent nucleus ground state and the states populated in the daughter nucleus. Total absorption spectrometers based on large NaI crystals are well suited tools to determine the beta -strength distribution over the whole Q /sub EC/ decay window. The newly built spectrometer TAgS, dedicated to such studies, is presented and its performances and possibilities are discussed in the light of experiments performed at the ISOLDE /CERN mass separator. The resulting information on ground state deformations for the /sup 74/Kr and /sup 76/Sr isotopes are discussed. (22 refs).

  5. BETA SPECTRA. I. Negatrons spectra; ESPECTROS BETA. I. Espectros simples de negatrones

    Energy Technology Data Exchange (ETDEWEB)

    Grau Malonda, A; Garcia-Torano, E

    1978-07-01

    Using the Fermi theory of beta decay, the beta spectra for 62 negatrons emitters have been computed introducing a correction factor for unique forbidden transitions. These spectra are plotted vs. energy, once normal i sed, and tabulated with the related Fermi functions. The average and median energies are calculated. (Author)

  6. Simultaneous beta and gamma spectroscopy

    Science.gov (United States)

    Farsoni, Abdollah T.; Hamby, David M.

    2010-03-23

    A phoswich radiation detector for simultaneous spectroscopy of beta rays and gamma rays includes three scintillators with different decay time characteristics. Two of the three scintillators are used for beta detection and the third scintillator is used for gamma detection. A pulse induced by an interaction of radiation with the detector is digitally analyzed to classify the type of event as beta, gamma, or unknown. A pulse is classified as a beta event if the pulse originated from just the first scintillator alone or from just the first and the second scintillator. A pulse from just the third scintillator is recorded as gamma event. Other pulses are rejected as unknown events.

  7. In vitro proliferation of adult human beta-cells.

    Directory of Open Access Journals (Sweden)

    Sabine Rutti

    Full Text Available A decrease in functional beta-cell mass is a key feature of type 2 diabetes. Glucagon-like peptide 1 (GLP-1 analogues induce proliferation of rodent beta-cells. However, the proliferative capacity of human beta-cells and its modulation by GLP-1 analogues remain to be fully investigated. We therefore sought to quantify adult human beta-cell proliferation in vitro and whether this is affected by the GLP-1 analogue liraglutide.Human islets from 7 adult cadaveric organ donors were dispersed into single cells. Beta-cells were purified by FACS. Non-sorted cells and the beta-cell enriched ("beta-cells" population were plated on extracellular matrix from rat (804G and human bladder carcinoma cells (HTB9 or bovine corneal endothelial ECM (BCEC. Cells were maintained in culture+/-liraglutide for 4 days in the presence of BrdU.Rare human beta-cell proliferation could be observed either in the purified beta-cell population (0.051±0.020%; 22 beta-cells proliferating out of 84'283 beta-cells counted or in the non-sorted cell population (0.055±0.011%; 104 proliferating beta-cells out of 232'826 beta-cells counted, independently of the matrix or the culture conditions. Liraglutide increased human beta-cell proliferation on BCEC in the non-sorted cell population (0.082±0.034% proliferating beta-cells vs. 0.017±0.008% in control, p<0.05.These results indicate that adult human beta-cell proliferation can occur in vitro but remains an extremely rare event with these donors and particular culture conditions. Liraglutide increases beta-cell proliferation only in the non-sorted cell population and only on BCEC. However, it cannot be excluded that human beta-cells may proliferate to a greater extent in situ in response to natural stimuli.

  8. Ionization detector with improved radiation source

    International Nuclear Information System (INIS)

    Solomon, E.F.

    1977-01-01

    The detector comprises a chamber having at least one radiation source disposed therein. The chamber includes spaced collector plates which form a part of a detection circuit for sensing changes in the ionization current in the chamber. The radiation source in one embodiment is in the form of a wound wire or ribbon suitably supported in the chamber and preferably a source of beta particles. The chamber may also include an adjustable electrode and the source may function as an adjustable current source by forming the wire or ribbon in an eliptical shape and rotating the structure. In another embodiment the source has a random shape and is homogeneously disposed in the chamber. 13 claims, 5 drawing figures

  9. Standardization of 56Co had been carried out using 4 pi beta-gamma coincidence methods

    International Nuclear Information System (INIS)

    Wardiyanto, Gatot; Pujadi

    2000-01-01

    Standardization of exp.56 Co had been carried out using 4 pi beta-gamma coincidence methods. The radionuclide use for calibration of nuclear instruments on range of energy over 1500 keV. The exp.56 Co had been produced by irradiation of proton by using a cyclotron with 15 MeV of energy and 300 mb of cross-section to natural iron target (99,5% of purity) at the Institute for Nuclear Study, University of Tokyo. Source preparation had been done by gravimetry method after the irradiated source was dissolved in 8N HCI solution. The disintegration rate had been measured using 4 pi beta-gamma coincidence apparatus, where the gamm gets sets on 511 and 847 keV gamma-rays. The result measurement is fairly good with the specific activity is 3078 n 15 Bq/mg

  10. Beta-Catenin Stability in Breast Cancer

    National Research Council Canada - National Science Library

    Baswaran, Vijay

    1999-01-01

    .... beta-catenin also binds the adenomatous polyposis coli protein (APC). The tumor suppressor function of APC is suggested to depend in part on its ability to bind beta-catenin and to facilitate beta-catenin degradation by an unknown mechanism...

  11. Determination of the Absolute Disintegration Rate of Cs-137 sources by the Tracer Method

    Energy Technology Data Exchange (ETDEWEB)

    Hellstroem, S; Brune, D

    1963-07-15

    {sup 137}Cs - sources were absolutely measured by the 'tracer method', with {sup 82}Br as a tracer nuclide and with application of the 4{pi} {beta}-{gamma} coincidence technique. A self-absorption of 6 % was found in sources obtained from a solution with a carrier-content of 400 {mu}g/ml. The precision of the method for the determination of the {beta}-emission rate was estimated to {+-} 1 %. The results were compared with those of other works.

  12. Transgenic overexpression of active calcineurin in beta-cells results in decreased beta-cell mass and hyperglycemia.

    Directory of Open Access Journals (Sweden)

    Ernesto Bernal-Mizrachi

    2010-08-01

    Full Text Available Glucose modulates beta-cell mass and function through an initial depolarization and Ca(2+ influx, which then triggers a number of growth regulating signaling pathways. One of the most important downstream effectors in Ca(2+ signaling is the calcium/Calmodulin activated serine threonine phosphatase, calcineurin. Recent evidence suggests that calcineurin/NFAT is essential for beta-cell proliferation, and that in its absence loss of beta-cells results in diabetes. We hypothesized that in contrast, activation of calcineurin might result in expansion of beta-cell mass and resistance to diabetes.To determine the role of activation of calcineurin signaling in the regulation of pancreatic beta-cell mass and proliferation, we created mice that expressed a constitutively active form of calcineurin under the insulin gene promoter (caCn(RIP. To our surprise, these mice exhibited glucose intolerance. In vitro studies demonstrated that while the second phase of Insulin secretion is enhanced, the overall insulin secretory response was conserved. Islet morphometric studies demonstrated decreased beta-cell mass suggesting that this was a major component responsible for altered Insulin secretion and glucose intolerance in caCn(RIP mice. The reduced beta-cell mass was accompanied by decreased proliferation and enhanced apoptosis.Our studies identify calcineurin as an important factor in controlling glucose homeostasis and indicate that chronic depolarization leading to increased calcineurin activity may contribute, along with other genetic and environmental factors, to beta-cell dysfunction and diabetes.

  13. Pengaruh Downside Beta, Upside Beta, Dan Beta Terhadap Expected Return (Studi Pada Saham Yang Termasuk Dalam 50 Leading Market Capitalization Di Bursa Efek Indonesia Periode 2012-2015)

    OpenAIRE

    Sinaga, Maria Goretty; Sulasmiyati, Sri

    2017-01-01

    Return or return on an investment is required by the investor. Most investors currently prefer shares in emerging markets. Return in the emerging market is not always symmetrical, it shows return in the emerging market is not normally distributed. The purposive of this research want to learn, compare, and explain about some model of stock risk. On this research downside risk expressed with beta downside. The models used in this research among others, dowside beta, upside beta, and beta. The k...

  14. Developments for the 6He beta - nu angular correlation experiment

    Science.gov (United States)

    Zumwalt, David W.

    This thesis describes developments toward the measurement of the angular correlation between the beta and the antineutrino in the beta decay of 6He. This decay is a pure Gamow-Teller decay which is described in the Standard Model as a purely axial vector weak interaction. The angular correlation is characterized by the parameter abetanu = -1/3 in the Standard Model. Any deviation from this value would be evidence for tensor components in the weak interaction and would constitute new physics. A new method will be used to measure the parameter a betanu from 6He decays, featuring a magneto-optical trap that will measure the beta particle in coincidence with the recoiling 6Li daughter ion. This neutral atom trapping scheme provides cold, tightly confined atoms which will reduce systematic uncertainties related to the initial position of the decay. By knowing the initial position of the decay and measuring the time of flight of the recoiling 6Li daughter ion in coincidence with the beta, the angular correlation between the beta and the antineutrino can be deduced. We aim to measure a betanu first to the level of 1%, and eventually to the 0.1% level, which would represent an order of magnitude improvement in precision over past experiments. Towards this goal, we have designed, built, and successfully tested a liquid lithium target to provide >2×10. {10} 6He atoms/sto a low-background environment, which is the most intense source of 6He presently available. This allowed for an additional measurement of the 6He half-life (806.89 +/- 0.11stat +0.23-0.19syst ms) to be made with unprecedented precision, resolving discrepancies in past measurements. We have also tested our trapping and detection apparatus and have begun to record preliminary coincidence events.

  15. Progress report on the Los Alamos tritium beta decay experiment

    International Nuclear Information System (INIS)

    Wilkerson, J.F.; Bowles, T.J.; Knapp, D.A.; Robertson, R.G.H.; Wark, D.L.

    1988-01-01

    Measurements near the endpoint of the tritium beta-decay spectrum using a gaseous molecular tritium source yield an essentially model-independent upper limit of 27 eV on the /ovr ν//sub e/ mass at the 95% confidence level. Since demonstrating from this initial measurement the successful operation of a gaseous source based system, most of our effort has been concentrated towards the upgrade and optimization of the experimental apparatus. The emphasis of this work has been to eliminate or further reduce effects that generate systematic errors. Based on realistic projections from our initial measurement, an ultimate sensitivity to neutrino mass of 10 eV is expected. 12 refs., 1 fig

  16. Selectivity of beta-adrenergic stimulating and blocking agents.

    Science.gov (United States)

    Löfdahl, C G; Svedmyr, N

    1984-01-01

    Studies have been performed to answer two questions: whether there are subgroups of beta 2-receptors separating effects in bronchial and skeletal muscle and whether beta 1-receptors in asthmatic airways mediate bronchoconstriction. Asthmatic patients have been studied in randomised cross-over trials. Effects on FEV1, heart rate and skeletal muscle tremor have been monitored. In some experimental studies, two new compounds, D2343 and QH-25, have shown a selectivity for beta 2-receptors in bronchial muscle compared to skeletal muscle. Studies in asthmatics did not confirm this. Thus, the beta 2-receptors in the two organs appear to be identical. The clinical effect of beta 1-receptors in the the airways was studied by giving selective beta 1-receptor blocking agents. It was shown that pafenolol , a beta-blocker more beta 1-selective than metoprolol, had less effect on FEV1 than metoprolol given in equipotent beta 1-blocking doses. Beta 1-receptor stimulation with a new selective beta 1-stimulating agent, prenalterol, did not give bronchodilation in doses which gave a significant increase of heart rate. Thus, beta 1-receptors do not contribute to bronchodilation in asthmatic patients.

  17. Sorting out Downside Beta

    NARCIS (Netherlands)

    G.T. Post (Thierry); P. van Vliet (Pim); S.D. Lansdorp (Simon)

    2009-01-01

    textabstractDownside risk, when properly defined and estimated, helps to explain the cross-section of US stock returns. Sorting stocks by a proper estimate of downside market beta leads to a substantially larger cross-sectional spread in average returns than sorting on regular market beta. This

  18. The best-beta CAPM

    NARCIS (Netherlands)

    Zou, L.

    2006-01-01

    The issue of 'best-beta' arises as soon as potential errors in the Sharpe-Lintner-Black capital asset pricing model (CAPM) are acknowledged. By incorporating a target variable into the investor preferences, this study derives a best-beta CAPM (BCAPM) that maintains the CAPM's theoretical appeal and

  19. Dosimetric methodology for extremities of individuals occupationally exposed to beta radiation using the optically stimulated luminescence technique

    International Nuclear Information System (INIS)

    Pinto, Teresa Cristina Nathan Outeiro

    2010-01-01

    A dosimetric methodology was established for the determination of extremity doses of individuals occupationally exposed to beta radiation, using Al 2 O 3 :C detectors and the optically stimulated luminescence (OSL) reader system microStar, Landauer. The main parts of the work were: characterization of the dosimetric material Al 2 O 3 :C using the OSL technique; establishment of the dose evaluation methodology; dose rate determination of beta radiation sources; application of the established method in a practical test with individuals occupationally exposed to beta radiation during a calibration simulation of clinical applicators; validation of the methodology by the comparison between the dose results of the practical test using the OSL and the thermoluminescence (TL) techniques. The results show that both the OSL Al-2O 3 :C detectors and the technique may be utilized for individual monitoring of extremities and beta radiation. (author)

  20. Beta genus papillomaviruses and skin cancer.

    Science.gov (United States)

    Howley, Peter M; Pfister, Herbert J

    2015-05-01

    A role for the beta genus HPVs in keratinocyte carcinoma (KC) remains to be established. In this article we examine the potential role of the beta HPVs in cancer revealed by the epidemiology associating these viruses with KC and supported by oncogenic properties of the beta HPV proteins. Unlike the cancer associated alpha genus HPVs, in which transcriptionally active viral genomes are invariably found associated with the cancers, that is not the case for the beta genus HPVs and keratinocyte carcinomas. Thus a role for the beta HPVs in KC would necessarily be in the carcinogenesis initiation and not in the maintenance of the tumor. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Beta thalassemia - a review

    Directory of Open Access Journals (Sweden)

    R Jha

    2014-09-01

    Full Text Available Thalassemia is a globin gene disorder that results in a diminished rate of synthesis of one or more of the globin chains. About 1.5% of the global population (80 to 90 million people are carriers of beta Thalassemia. More than 200 mutations are described in beta thalassemia. However not all mutations are common in different ethnic groups. The only effective way to reduce burden of thalassemia is to prevent birth of homozygotes. Diagnosis of beta thalassemia can be done by fetal DNA analysis for molecular defects of beta thalassemia or by fetal blood analysis. Hematopoietic stem cell transplantation is the only available curative approach for Thalassemia. Many patients with thalassemia in underdeveloped nations die in childhood or adolescence. Programs that provide acceptable care, including transfusion of safe blood and supportive therapy including chelation must be established.DOI: http://dx.doi.org/10.3126/jpn.v4i8.11609 Journal of Pathology of Nepal; Vol.4,No. 8 (2014 663-671

  2. The changes in beta-adrenoceptor-mediated cardiac function in experimental hypothyroidism: the possible contribution of cardiac beta3-adrenoceptors.

    Science.gov (United States)

    Arioglu, E; Guner, S; Ozakca, I; Altan, V M; Ozcelikay, A T

    2010-02-01

    Thyroid hormone deficiency has been reported to decrease expression and function of both beta(1)- and beta(2)-adrenoceptor in different tissues including heart. The purpose of this study was to examine the possible contribution of beta(3)-adrenoceptors to cardiac dysfunction in hypothyroidism. In addition, effect of this pathology on beta(1)- and beta(2)-adrenoceptor was investigated. Hypothyroidism was induced by adding methimazole (300 mg/l) to drinking water of rats for 8 weeks. Cardiac hemodynamic parameters were measured in anesthetised rats in vivo. Responses to beta-adrenoceptor agonists were examined in rat papillary muscle in vitro. We also studied the effect of hypotyroidism on mRNA expression of beta-adrenoceptors, Gialpha, GRK, and eNOS in rat heart. All of the hemodynamic parameters (systolic, diastolic and mean arterial pressure, left ventricular pressure, heart rate, +dp/dt, and -dp/dt) were significantly reduced by the methimazole treatment. The negative inotropic effect elicited by BRL 37344 (a beta(3)-adrenoceptor preferential agonist) and positive inotropic effects produced by isoprenaline and noradrenaline, respectively, were significantly decreased in papillary muscle of hypothyroid rats as compared to those of controls. On the other hand, hypothyroidism resulted in increased cardiac beta(2)- and beta(3)-adrenoceptor, Gialpha(2), Gialpha(3), GRK3, and eNOS mRNA expressions. However, beta(1)-adrenoceptor and GRK2 mRNA expressions were not changed significantly in this pathology. These results show that mRNA expression of beta(3)-adrenoceptors as well as the signalling pathway components mediated through beta(3)-adrenoceptors are significantly increased in hypothyroid rat heart. Since we could not correlate these alternates with the decreased negative inotropic response mediated by this receptor subtype, it is not clear whether these changes are important for hypothyroid induced reduction in cardiac function.

  3. TLD DRD dose discrepancy: role of beta radiation fields

    International Nuclear Information System (INIS)

    Munish Kumar; Pradhan, S.M.; Bihari, R.R.; Bakshi, A.K.; Chougaonkar, M.P.; Babu, D.A.R.; Gupta, Anil

    2014-01-01

    Ionization chamber based direct reading/pocket dosimeters (DRDs), are used along with the legal dosimeters (thermoluminescent dosimeters-TLDs) for day to day monitoring and control of radiation doses received by radiation workers. The DRDs are routinely used along with the passive dosimeters (TLDs) in nuclear industry at different radiation installations where radiation levels could vary significantly and the possibility of receiving doses beyond investigation levels by radiation workers is not ruled out. Recently, recommendations for dealing with discrepancies between personal dosimeter systems used in parallel were issued by ISO. The present study was performed to measure the response of ionization chamber based pocket dosimeters to various beta sources having energy (E max ) ranging from 0.224 MeV-3.54 MeV. It is expected that the above study will be useful in resolving the disparity between TLD and DRD doses at those radiation installations where radiation workers are likely to be exposed simultaneously from photons and beta particles

  4. Primary and scattering contributions to beta scaled dose point kernels by means of Monte Carlo simulations; Contribuicoes primaria e espalhada para dosimetria beta calculadas pelo dose point kernels empregando simulacoes pelo Metodo Monte Carlo

    Energy Technology Data Exchange (ETDEWEB)

    Valente, Mauro [CONICET - Consejo Nacional de Investigaciones Cientificas y Tecnicas de La Republica Argentina (Conicet), Buenos Aires, AR (Brazil); Botta, Francesca; Pedroli, Guido [European Institute of Oncology, Milan (Italy). Medical Physics Department; Perez, Pedro, E-mail: valente@famaf.unc.edu.ar [Universidad Nacional de Cordoba, Cordoba (Argentina). Fac. de Matematica, Astronomia y Fisica (FaMAF)

    2012-07-01

    Beta-emitters have proved to be appropriate for radioimmunotherapy. The dosimetric characterization of each radionuclide has to be carefully investigated. One usual and practical dosimetric approach is the calculation of dose distribution from a unit point source emitting particles according to any radionuclide of interest, which is known as dose point kernel. Absorbed dose distributions are due to primary and radiation scattering contributions. This work presented a method capable of performing dose distributions for nuclear medicine dosimetry by means of Monte Carlo methods. Dedicated subroutines have been developed in order to separately compute primary and scattering contributions to the total absorbed dose, performing particle transport up to 1 keV or least. Preliminarily, the suitability of the calculation method has been satisfactory, being tested for monoenergetic sources, and it was further applied to the characterization of different beta-minus radionuclides of nuclear medicine interests for radioimmunotherapy. (author)

  5. Standardization of low energy beta and beta-gamma complex emitters by the tracer and the efficiency extrapolation methods

    International Nuclear Information System (INIS)

    Sahagia, M.

    1978-01-01

    The absolute standardization of radioactive solutions of low energy beta emitters and beta-gamma emitters with a high probability of disintegration to the ground state is described; the tracer and the efficiency extrapolation methods were used. Both types of radionuclides were mathematically and physically treated in an unified manner. The theoretical relations between different beta spectra were calculated according to Williams' model and experimentally verified for: 35 S + 60 Co, 35 S + 95 Nb, 147 Pm + 60 Co, 14 C + 95 Nb and two beta branches of 99 Mo. The optimum range of beta efficiency variation was indicated. The basic supposition that all beta efficieny tend to unity in the same time was experimentally verified, using two 192 Ir beta branches. Four computer programs, written in the FORTRAN IV language, were elaborated, for the adequate processing of the experimental data. Good precision coefficients according to international standards were obtained in the absolute standardization of 35 S, 147 Pm, 99 Mo solutions. (author)

  6. Beta-lactamases in Enterobacteriaceae in broilers

    NARCIS (Netherlands)

    Dierikx, C.M.

    2013-01-01

    Resistance to cephalosprins due to the production of extended spectrum beta-lactamases (ESBLs) or plasmid mediated AmpC beta-lactamases is increasingly found in infections in humans outside the hospital. The genes encoding for these beta-lactamases are located on mobile DNA (plasmids), which can be

  7. Simultaneous determination of F-beta-alanine and beta-alanine in plasma and urine with dual-column reversed-phase high-performance liquid chromatography

    NARCIS (Netherlands)

    van Kuilenburg, A. B.; Stroomer, A. E.; Peters, G. J.; van Gennip, A. H.

    2001-01-01

    F-beta-Alanine and beta-alanine were detected in plasma and urine samples with fluorescence detection of orthophthaldialdehyde derivatives of F-beta-alanine and beta-alanine after separation with dual-column reversed-phase HPLC. The detection limits of F-beta-alanine and beta-alanine in the HPLC

  8. Rat beta-LPH, gamma-LPH and beta-endorphin biosynthesized by isolated cells of pars intermedia and pars distalis

    International Nuclear Information System (INIS)

    Gianoulakis, C.; Seidah, N.G.; Routhier, R.; Chretien, M.

    1980-01-01

    Rats pars intermedia cells were incubated for 3 h with the following amino-acids: a) 35 S-methionine and 3 H-phenylalamine; b) 3 H-valine; and c) 3 H-valine and 3 H-lysine. Radioactive gamma-lipotropin, beta-lipotropin and beta-endorphin were purified on carboxy- methyl-cellulose and characterized by polyacrylamide disc gel electrophoresis af pH 4.5, molecular weight estimation and microsequencing. Rat gamma-lipotropin was shown to differ slightly from ovine gamma-lipotropin in its NH 2 -terminal amino acid sequence, in containing no methionine and having phenylalanine at position 6, valine at positions 13 and 27, and lysine at position 20. The same variations were observed in the sequence of rat beta-lipotropin, while rat beta-endorphin was shown to be identical to the ovine beta-endorphin. Following a 3-h pulse of rat pars distalis, the cells were extracted with care to avoid beta-lipotropin degradation by proteolytic enzymes. A peptide was purified and identified to be rat beta-endorphin, thus demonstrating that beta-endorphin is biosynthesized in pars distalis and is not an extraction artifact. (author)

  9. El factor de crecimiento transformante beta como blanco terapéutico Transforming growth factor-beta as a therapeutic target

    Directory of Open Access Journals (Sweden)

    Francisco Javier Gálvez-Gastélum

    2004-08-01

    Full Text Available El factor de crecimiento transformante beta (TGF-beta es una familia de proteínas que incluye al TGF-beta, activinas y a la proteína morfogénica de hueso (BMP, por sus siglas en inglés, citocinas que son secretadas y se relacionan estructuralmente en diferentes especies de metazoarios. Los miembros de la familia del TGF-beta regulan diferentes funciones celulares como proliferación, apoptosis, diferenciación, migración, y tienen un papel clave en el desarrollo del organismo. El TGF-beta está implicado en varias patologías humanas, incluyendo desórdenes autoinmunes y vasculares, así como enfermedades fibróticas y cáncer. La activación del receptor del TGF-beta propicia su fosforilación en residuos de serina/treonina y dispara la fosforilación de proteínas efectoras intracelulares (smad, que una vez activas se translocan al núcleo para inducir la transcripción de genes blanco, y así regular procesos y funciones celulares. Se están desarrollando novedosas estrategias terapéuticas encaminadas a corregir las alteraciones presentes en patologías que involucran al TGF-beta como actor principal.Transforming growth factor-beta (TGF-beta family members include TGF-beta, activins, and bone morphogenetic proteins (BMP. These proteins are structurally related cytokines secreted in diverse Metazoans. TGF-beta family members regulate cellular functions such as proliferation, apoptosis, differentiation, and migration, and play an important role in organism development. Deregulated TGF-beta family signaling participates in various human pathologies including auto-immune diseases, vascular disorders, fibrotic disease, and cancer. Ligand-induced activation of TGF-beta family receptors with intrinsic serine/threonine kinase activity, triggers phosphorylation of the intracellular effectors of TGF-beta signaling, the Smads proteins. Once these proteins are activated they translocate into the nucleus, where they induce transcription of target

  10. PERIPHERAL LIPOPOLYSACCHARIDE STIMULATION INDUCES INTERLEUKIN-1-BETA MESSENGER-RNA IN RAT-BRAIN MICROGLIAL CELLS

    NARCIS (Netherlands)

    BUTTINI, M; BODDEKE, H

    The inflammatory cytokine interleukin-1 acts as an endogenous pyrogen in organisms affected by infectious diseases and has been shown to influence the activity of the central nervous system. Using in situ hybridization histochemistry, we have examined the cellular source of interleukin-1 beta in rat

  11. Appraisal of beta-Phellandrene in Callus Cultures of Momordica charantia L. Cultivars, Jaunpuri and Jhalri

    International Nuclear Information System (INIS)

    Ali, S.; Tariq, A.; Ajaib, M.

    2015-01-01

    Secondary metabolite beta-phellandrene was analyze in callus cultures of two varieties of Momordica charantia L. i.e. Jaunpuri and Jhalri. Conditions for seed germination and callus induction were optimized. Seedlings grown under aseptic conditions served as explant sources. 6-Benzylaminopurine (BAP) and 2,4-dichlorophenoxyacetic acid (2,4-D) supplemented in Murashige and Skoog's (MS) medium were scrutinized as the most suitable combination of plant growth regulators with different concentrations for callus induction in both the varieties. Cotyledon explant of (cultivars) cv. Jaunpuri revealed maximum callus induction with 1.0 mgl/sup -1/ BAP and 1.5 mgl/sup -1/ 2,4-D in eight days as compared to internode, apical bud and leaf. Cotyledon and leaf explants of cv. Jhalri responded to 1.5 mgl/sup -1/ BAP and 1.0 mgl/sup -1/ 2,4-D in nine days for callus and internode and apical bud with 1.0 mgl-l BAP and 1.5 mgl-l 2,4-D. Best grown calli from different explants were analyzed through GC-MS for production of secondary metabolites. Along with other secondary metabolites beta-phellandrene was the most prominent secondary metabolites found in in vitro grown callus cultures of both the varieties. The callus cultures of cv. Jaunpuri produced substantial amount of beta-phellandrene i.e. up to 30 percent of the total secondary metabolites as compared to calli from cv. Jhalri explants. The callus cultures of M. charantia can prove the best alternative, rapid and uninterrupted source for natural beta-phellandrene production. (author)

  12. Transforming growth factor. beta. sub 1 is present at sites of extracellular matrix gene expression in human pulmonary fibrosis

    Energy Technology Data Exchange (ETDEWEB)

    Broekelmann, T.J.; Limper, A.H.; McDonald, J.A. (Washington Univ., St. Louis, MO (United States)); Colby, T.V. (Mayo Clinic, Rochester, MN (United States))

    1991-08-01

    Idiopathic pulmonary fibrosis is an inexorably fatal disorder characterized by connective tissue deposition within the terminal air spaces resulting in loss of lung function and eventual respiratory failure. Previously, the authors demonstrated that foci of activated fibroblasts expressing high levels of fibronectin, procollagen, and smooth muscle actin and thus resembling those found in healing wounds are responsible for the connective tissue deposition and scarring in idiopathic pulmonary fibrosis. Using in situ hybridization and immunohistochemistry, they now demonstrate the presence of transforming growth factor {beta}{sub 1} (TGF-{beta}{sub 1}), a potent profibrotic cytokine, in the foci containing these activated fibroblasts. These results suggest that matrix-associated TGF-{beta}{sub 1} may serve as a stimulus for the persistent expression of connective tissue genes. One potential source of the TGF-{beta}{sub 1} is the alveolar macrophage, and they demonstrate the expression of abundant TGF-{beta}{sub 1} mRNA in alveolar macrophages in lung tissue from patients with idiopathic pulmonary fibrosis.

  13. An application of Brookhaven National Laboratory's hot particle methodology for determining the most effective beta particle energy in causing skin ulcers

    International Nuclear Information System (INIS)

    Schaefer, C.

    1994-11-01

    The purpose of this project was to compare the effectiveness of hot particles with different energy betas in producing ulcers on skin. The sources were man-made hot particles similar in size and activity to those found in the commercial nuclear power industry. Four different particle types were used. These were thulium (Tm-170) with a 0.97 MeV maximum energy beta, ytterbium (Yb-175) with a maximum beta energy of 0.47 MeV, scandium (Sc-46) with a 0.36 MeV beta, which was used as a surrogate for cobalt-60 (0.31 MeV beta) and uranium (in the carbide form) with an average maximum beta energy of about 2.5 MeV. Since higher energy beta particles penetrate further in skin, they will affect a higher number and different populations of target cells. The experiments were designed as threshold studies such that the dose needed to produce ulcers ten percent of the time (ED 10%) for each particle type could be compared against each other

  14. Beta particle measurement fundamentals

    International Nuclear Information System (INIS)

    Alvarez, J.L.

    1986-01-01

    The necessary concepts for understanding beta particle behavior are stopping power, range, and scattering. Dose as a consequence of beta particle interaction with tissue can be derived and explained by these concepts. Any calculations of dose, however, assume or require detailed knowledge of the beta spectrum at the tissue depth of calculation. A rudimentary knowledge of the incident spectrum can be of use in estimating dose, interpretating dose measuring devices and designing protection. The stopping power and range based on the csda will give a conservative estimate in cases of protection design, as scattering will reduce the range. Estimates of dose may be low because scattering effects were neglected

  15. Direct ethanol production from barley beta-glucan by sake yeast displaying Aspergillus oryzae beta-glucosidase and endoglucanase.

    Science.gov (United States)

    Kotaka, Atsushi; Bando, Hiroki; Kaya, Masahiko; Kato-Murai, Michiko; Kuroda, Kouichi; Sahara, Hiroshi; Hata, Yoji; Kondo, Akihiko; Ueda, Mitsuyoshi

    2008-06-01

    Three beta-glucosidase- and two endoglucanase-encoding genes were cloned from Aspergillus oryzae, and their gene products were displayed on the cell surface of the sake yeast, Saccharomyces cerevisiae GRI-117-UK. GRI-117-UK/pUDB7 displaying beta-glucosidase AO090009000356 showed the highest activity against various substrates and efficiently produced ethanol from cellobiose. On the other hand, GRI-117-UK/pUDCB displaying endoglucanase AO090010000314 efficiently degraded barley beta-glucan to glucose and smaller cellooligosaccharides. GRI-117-UK/pUDB7CB codisplaying both beta-glucosidase AO090009000356 and endoglucanase AO090010000314 was constructed. When direct ethanol fermentation from 20 g/l barley beta-glucan as a model substrate was performed with the codisplaying strain, the ethanol concentration reached 7.94 g/l after 24 h of fermentation. The conversion ratio of ethanol from beta-glucan was 69.6% of the theoretical ethanol concentration produced from 20 g/l barley beta-glucan. These results showed that sake yeast displaying A. oryzae cellulolytic enzymes can be used to produce ethanol from cellulosic materials. Our constructs have higher ethanol production potential than the laboratory constructs previously reported.

  16. Analysis of interleukin (IL)-1 beta and transforming growth factor (TGF)-beta-induced signal transduction pathways in IL-2 and TGF-beta secretion and proliferation in the thymoma cell line EL4.NOB-1.

    Science.gov (United States)

    Siese, A; Jaros, P P; Willig, A

    1999-02-01

    In the present study we investigated the interleukin (IL)-1beta and transforming growth factor-beta1 (TGF-beta1)-mediated proliferation, and production of IL-2 and TGF-beta, in the murine T-cell line, EL4.NOB-1. This cell line is resistant to TGF-beta concerning growth arrest but not autoinduction or suppression of IL-1-induced IL-2 production. When cocultured with IL-1beta, TGF-beta showed growth-promoting activity that could be antagonized by adding the phosphatidyl choline-dependent phospholipase C (PC-PLC) inhibitor, D609. Using specific enzyme inhibitors of protein kinases (PK) C and A, mitogen-activated protein kinase (MAPK), phospholipase A2 (PLA2), phosphatidylinositol-dependent (PI)-PLC and PC-PLC, we showed that IL-1beta-induced IL-2 synthesis was dependent on all investigated kinases and phospholipases, except PC-PLC. TGF-beta1 was able to inhibit IL-2 synthesis by the activation of PKA and MAPK. The same kinases are involved in TGF-beta autoinduction that is accompanied by a secretion of the active but not the latent growth factor and is antagonized by IL-1beta. Addition of the PI-PLC inhibitor, ET 18OCH3, or the PLA2 inhibitor (quinacrine) alone, resulted in secretion of latent TGF-beta and, in the case of ET 18OCH3, active TGF-beta. These data implicate a role for PI-PLC and PLA2 in the control of latency and secretion. Analysis of specific tyrosine activity and c-Fos expression showed synergistic but no antagonistic effects. These events are therefore not involved in IL- and TGF-beta-regulated IL-2 and TGF-beta production, but might participate in IL-1/TGF-beta-induced growth promotion.

  17. Monitor for alpha beta contamination of hands; Moniteur de contamination alpha beta des mains

    Energy Technology Data Exchange (ETDEWEB)

    Guitton, J

    1958-07-01

    The following specifications of hands alpha beta contamination monitor are presented: the position of the hands, the detection and separation of alpha and beta, the information processing, the programming, the results presentation and general characteristics. (A.L.B.)

  18. Determination of the neutrino mass from the beta decay of gaseous molecular tritium

    International Nuclear Information System (INIS)

    Decman, D.J.; Stoeffl, W.

    1992-06-01

    We set an upper limit of 8 eV for the mass of the electron antineutrino from studying the beta decay of tritium. We use a gaseous molecular tritium source, a high resolution magnetic spectrometer and a low background counting system to minimize the systematic errors encountered in these measurements. Our calibration data with radioactive 83m Kr enables us to measure our system response function and a good deal of atomic physics data. In addition to our end point results we have made the first measurement of the tritium beta decay spectrum below 200 keV. We find an excess of very low energy electrons which arise from molecular processes of the 3 He-T + ion

  19. Determining the hierarchy of neutrino masses with high density magnetized detectors at the Beta Beams

    International Nuclear Information System (INIS)

    Donini, A.; Fernandez-Martinez, E.; Rigolin, S.; Migliozzi, P.; Lavina, L. Scotto; Selvi, M.; De Fatis, T. Tabarelli; Terranova, F.

    2008-01-01

    Multi-kton iron detectors can be simultaneously exploited as far detectors for high energy Beta Beams and to determine the atmospheric ν μ flux in the multi-GeV range. These measurements can be combined in a highly non trivial manner to improve the sensitivity to the hierarchy of neutrino masses. Considering a Super-SPS based Beta Beam and a 40 kton far detector located ∼700 km from the source (CERN to Gran Sasso distance), we demonstrate that even with moderate detector granularities the sign of Δm 13 2 can be determined for θ 13 values greater than 4 deg.

  20. Does Beta Explain Global Equity Market Volatility – Some Empirical Evidence

    Directory of Open Access Journals (Sweden)

    Radosław Kurach

    2013-06-01

    Full Text Available The purpose of this study is to assess the diversification benefits resulting from international asset allocation. In this study, we examine Capital Asset Pricing Model (CAPM in its international context (ICAPM using the monthly equity returns for 26 countries (18 developed and 8 emerging markets between July 1996 and June 2011 and adopting the US investor’s perspective. We verify the beta-return trade-off employing two approaches: the unconditional trade-off and the conditional relationship. In this latter case, we find the country beta to be a significant variable explaining the cross-country variation of returns. Next, we test the degree of market integration in the light of the ICAPM. The results of this test indicate that country-idiosyncratic risks are generally not priced. In the subsidiary outcomes of our verification procedure, we argue that country betas are time-varying and that currently, global factors are the dominant source of equity market volatility. Consequently, the opinion regarding emerging market assets and their role in global portfolio management should be reconsidered. The results of the entire study may provide essential implications for fund managers because the decreasing international diversification gains have been identified.

  1. Beta-structures in fibrous proteins.

    Science.gov (United States)

    Kajava, Andrey V; Squire, John M; Parry, David A D

    2006-01-01

    The beta-form of protein folding, one of the earliest protein structures to be defined, was originally observed in studies of silks. It was then seen in early studies of synthetic polypeptides and, of course, is now known to be present in a variety of guises as an essential component of globular protein structures. However, in the last decade or so it has become clear that the beta-conformation of chains is present not only in many of the amyloid structures associated with, for example, Alzheimer's Disease, but also in the prion structures associated with the spongiform encephalopathies. Furthermore, X-ray crystallography studies have revealed the high incidence of the beta-fibrous proteins among virulence factors of pathogenic bacteria and viruses. Here we describe the basic forms of the beta-fold, summarize the many different new forms of beta-structural fibrous arrangements that have been discovered, and review advances in structural studies of amyloid and prion fibrils. These and other issues are described in detail in later chapters.

  2. Overview of light sources powered by tritium

    International Nuclear Information System (INIS)

    Wu Jian; Lei Jiarong; Liu Wenke

    2012-01-01

    Due to their long lifespan and stable intensity, light sources initiated by tritium instead of electricity or batteries are suitable for low level lighting applications. Therefore, tritium-based radioluminescent (RL) light sources are widely used in both military and civil applications. However, traditional tritium lights with the gas tube structure have several shortcomings: (1) the phosphors are opaque; (2) the glass tube is fragile and easily broken; and (3) the beta kinetic energy is attenuated due to the sorption by the gas; etc. As a result, further application of the tritium lights is limited. In this paper, the lighting mechanism and radiation safety of tritium-based RL light sources are briefly reviewed. Besides, the history and prospects of the development of tritium-based RL light source are discussed. Due to their long lifespan and stable intensity, light sources initiated by tritium instead of electricity or batteries are suitable for low level lighting applications. Therefore, tritium- based radioluminescent (RL) light sources are widely used in both military and civil applications. However, traditional tritium lights with the gas tube structure have several short- comings: (1) the phosphors are opaque; (2) the glass tube is fragile and easily broken; and (3) the beta kinetic energy is attenuated due to the sorption by the gas; etc. As a result, further application of the tritium lights is limited. In this paper, the lighting mechanism and radiation safety of tritium-based RL, light sources are briefly reviewed. Besides, the history and prospects of the development of tritium-based RL light source are discussed. (authors)

  3. Crystal scintillators for use in check-light source for thermoluminescent systems

    Science.gov (United States)

    Nagpal, J. S.; Sabharwal, S. C.; Chougaonkar, M. P.; Godbole, S. V.

    1999-08-01

    Beta ( 63Ni, Emax 0.063 MeV) excited radioluminescence of indigenously grown crystal scintillators CsI(Tl), Bi 4Ge 3O 12 and CdWO 4 has been studied for its use in check-light source needed for thermoluminescence systems. Temperature coefficient of the light output over 298-323 K and the beta-induced TL of the scintillators over 298-553 K are reported.

  4. Partitioning diversity into independent alpha and beta components.

    Science.gov (United States)

    Jost, Lou

    2007-10-01

    Existing general definitions of beta diversity often produce a beta with a hidden dependence on alpha. Such a beta cannot be used to compare regions that differ in alpha diversity. To avoid misinterpretation, existing definitions of alpha and beta must be replaced by a definition that partitions diversity into independent alpha and beta components. Such a unique definition is derived here. When these new alpha and beta components are transformed into their numbers equivalents (effective numbers of elements), Whittaker's multiplicative law (alpha x beta = gamma) is necessarily true for all indices. The new beta gives the effective number of distinct communities. The most popular similarity and overlap measures of ecology (Jaccard, Sorensen, Horn, and Morisita-Horn indices) are monotonic transformations of the new beta diversity. Shannon measures follow deductively from this formalism and do not need to be borrowed from information theory; they are shown to be the only standard diversity measures which can be decomposed into meaningful independent alpha and beta components when community weights are unequal.

  5. A fitness cost associated with the antibiotic resistance enzyme SME-1 beta-lactamase.

    Science.gov (United States)

    Marciano, David C; Karkouti, Omid Y; Palzkill, Timothy

    2007-08-01

    The bla(TEM-1) beta-lactamase gene has become widespread due to the selective pressure of beta-lactam use and its stable maintenance on transferable DNA elements. In contrast, bla(SME-1) is rarely isolated and is confined to the chromosome of carbapenem-resistant Serratia marcescens strains. Dissemination of bla(SME-1) via transfer to a mobile DNA element could hinder the use of carbapenems. In this study, bla(SME-1) was determined to impart a fitness cost upon Escherichia coli in multiple genetic contexts and assays. Genetic screens and designed SME-1 mutants were utilized to identify the source of this fitness cost. These experiments established that the SME-1 protein was required for the fitness cost but also that the enzyme activity of SME-1 was not associated with the fitness cost. The genetic screens suggested that the SME-1 signal sequence was involved in the fitness cost. Consistent with these findings, exchange of the SME-1 signal sequence for the TEM-1 signal sequence alleviated the fitness cost while replacing the TEM-1 signal sequence with the SME-1 signal sequence imparted a fitness cost to TEM-1 beta-lactamase. Taken together, these results suggest that fitness costs associated with some beta-lactamases may limit their dissemination.

  6. Conditional Betas and Investor Uncertainty

    OpenAIRE

    Fernando D. Chague

    2013-01-01

    We derive theoretical expressions for market betas from a rational expectation equilibrium model where the representative investor does not observe if the economy is in a recession or an expansion. Market betas in this economy are time-varying and related to investor uncertainty about the state of the economy. The dynamics of betas will also vary across assets according to the assets' cash-flow structure. In a calibration exercise, we show that value and growth firms have cash-flow structures...

  7. [{sup 18}F]{beta}-CIT-FP is superior to [{sup 11}C]{beta}-CIT-FP for quantitation of the dopamine transporter

    Energy Technology Data Exchange (ETDEWEB)

    Lundkvist, Camilla; Halldin, Christer; Ginovart, Nathalie; Swahn, Carl-Gunnar; Farde, Lars

    1997-10-01

    {beta}-CIT-FP [N-(3-fluoropropyl)-2{beta}-carbomethoxy-3{beta}-(4-iodophenyl)nortropane] is a cocaine analogue with high affinity for the dopamine transporter. Positron emission tomography (PET) studies with [O-methyl-{sup 11}C]{beta}-CIT-FP ([{sup 11}C]{beta}-CIT-FP) has shown that equilibrium conditions were approached but, however, not reached at the end of measurement. Moreover, metabolite studies of [{sup 11}C]{beta}-CIT-FP in monkey plasma demonstrated a lipophilic-labelled metabolite that may enter the brain. We therefore labelled {beta}-CIT-FP with fluorine-18 in a position that may avoid the formation of labelled lipophilic metabolites. The more long-lived radionuclide ({sup 18}F) was used to allow for measurements over longer time. [N-fluoropropyl-{sup 18}F]{beta}-CIT-FP ([{sup 18}F]{beta}-CIT-FP) was prepared by N-alkylation of nor-{beta}-CIT with [{sup 18}F]fluoropropyl bromide. PET studies were performed in cynomolgus monkeys. [{sup 18}F]{beta}-CIT-FP entered the brain rapidly. There was a high concentration of radioactivity in the striatum and much lower in the thalamus, neocortex, and cerebellum. The striatum-to-cerebellum ratio was about 5 at time of transient equilibrium, which occurred after 60 to 100 min. After pretreatment with GBR 12909, radioactivity in the striatum was markedly reduced, thus indicating specific [{sup 18}F]{beta}-CIT-FP binding to the dopamine transporter. The fraction of unchanged [{sup 18}F]{beta}-CIT-FP determined by HPLC was 10-15% after 140 min. No lipophilic labelled metabolites were detected. The absence of measurable lipophilic labelled metabolites and the occurrence of transient equilibrium within the time of the PET measurement indicate that [{sup 18}F]{beta}-CIT-FP is superior to [{sup 11}C]{beta}-CIT-FP as a PET radioligand for quantification of the dopamine transporter in the human brain.

  8. Reduced beta-adrenergic receptor activation decreases G-protein expression and beta-adrenergic receptor kinase activity in porcine heart.

    OpenAIRE

    Ping, P; Gelzer-Bell, R; Roth, D A; Kiel, D; Insel, P A; Hammond, H K

    1995-01-01

    To determine whether beta-adrenergic receptor agonist activation influences guanosine 5'-triphosphate-binding protein (G-protein) expression and beta-adrenergic receptor kinase activity in the heart, we examined the effects of chronic beta 1-adrenergic receptor antagonist treatment (bisoprolol, 0.2 mg/kg per d i.v., 35 d) on components of the myocardial beta-adrenergic receptor-G-protein-adenylyl cyclase pathway in porcine myocardium. Three novel alterations in cardiac adrenergic signaling as...

  9. The {beta}-decay Paul trap: A radiofrequency-quadrupole ion trap for precision {beta}-decay studies

    Energy Technology Data Exchange (ETDEWEB)

    Scielzo, N.D., E-mail: scielzo1@llnl.gov [Physics Division, Argonne National Laboratory, Argonne, Illinois 60439 (United States); Physical and Life Sciences Directorate, Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); Li, G. [Physics Division, Argonne National Laboratory, Argonne, Illinois 60439 (United States); Department of Physics, McGill University, Montreal, Quebec, Canada H3A 2T8 (Canada); Sternberg, M.G.; Savard, G. [Physics Division, Argonne National Laboratory, Argonne, Illinois 60439 (United States); Department of Physics, University of Chicago, Chicago, Illinois 60637 (United States); Bertone, P.F. [Physics Division, Argonne National Laboratory, Argonne, Illinois 60439 (United States); Buchinger, F. [Department of Physics, McGill University, Montreal, Quebec, Canada H3A 2T8 (Canada); Caldwell, S. [Physics Division, Argonne National Laboratory, Argonne, Illinois 60439 (United States); Department of Physics, University of Chicago, Chicago, Illinois 60637 (United States); Clark, J.A. [Physics Division, Argonne National Laboratory, Argonne, Illinois 60439 (United States); Crawford, J. [Department of Physics, McGill University, Montreal, Quebec, Canada H3A 2T8 (Canada); Deibel, C.M. [Physics Division, Argonne National Laboratory, Argonne, Illinois 60439 (United States); Joint Institute for Nuclear Astrophysics, Michigan State University, East Lansing, Michigan 48824 (United States); Fallis, J. [Physics Division, Argonne National Laboratory, Argonne, Illinois 60439 (United States); Department of Physics and Astronomy, University of Manitoba, Winnipeg, Manitoba, Canada R3T 2N2 (Canada); Greene, J.P. [Physics Division, Argonne National Laboratory, Argonne, Illinois 60439 (United States); and others

    2012-07-21

    The {beta}-decay Paul trap is a linear radiofrequency-quadrupole ion trap that has been developed for precision {beta}-decay studies. The design of the trap electrodes allows a variety of radiation detectors to surround the cloud of trapped ions. The momentum of the low-energy recoiling daughter nuclei following {beta} decay is negligibly perturbed by scattering and is available for study. This advantageous property of traps allows the kinematics of particles that are difficult or even impossible to directly detect to be precisely reconstructed using conservation of energy and momentum. An ion-trap system offers several advantages over atom traps, such as higher trapping efficiencies and element-independent capabilities. The first precision experiment using this system is a measurement of {beta}-decay angular correlations in the decay of {sup 8}Li performed by inferring the momentum of the neutrino from the kinematic shifts imparted to the breakup {alpha} particles. Many other {beta}-decay studies that would benefit from a determination of the nuclear recoil can be performed with this system.

  10. Adverse CNS-effects of beta-adrenoceptor blockers.

    Science.gov (United States)

    Gleiter, C H; Deckert, J

    1996-11-01

    In 1962 propranolol, the first beta adrenoceptor antagonist (beta blocker), was brought on to the market. There is now a host of different beta blockers available, and these compounds are among the most commonly prescribed groups of drugs. The efficacy of beta blockers has been proven predominantly for the treatment of cardiovascular diseases. Beta blockers are also used for certain types of CNS disorders, such as anxiety disorders, essential tremor and migraine. While low toxicity means that they have a favorable risk-benefit ratio, given the high intensity of use, it is essential to have a comprehensive knowledge of adverse events. Adverse events of beta blockers that can be related to the CNS are quite often neglected, even in textbooks of clinical pharmacology or review articles, and thus often misdiagnosed. The following article, therefore, after summarizing the use of beta blockers for CNS indications, critically reviews the literature on centrally mediated adverse events. General pharmacological features of beta blockers and their molecular basis of action will briefly be addressed to the extent that they are or may become relevant for central nervous pharmacotherapy and side-effects.

  11. $\\beta$ decay of $^{47}$Ar

    CERN Document Server

    Weissman, L; Bergmann, U C; Brown, B A; Catherall, R; Cederkäll, J; Dillmann, I; Hallmann, O; Fraile-Prieto, L M; Franchoo, S; Gaudefroy, L; Köster, U; Kratz, K L; Pfeiffer, B; Sorlin, O; 10.1103/PhysRevC.70.024304

    2004-01-01

    Information on beta -decay properties of neutron-rich /sup 47/Ar was obtained at the ISOLDE facility at CERN using isobaric selectivity. This was achieved by a combination of a plasma-ion source with a cooled transfer line and subsequent mass separation. A doubly charged beam was used in order to improve the signal-to-background ratio associated with multi-charged noble gas fission products. The identification of the /sup 47/Ar gamma -ray transitions was performed by comparing the spectra obtained from direct proton bombardment of the target and of the neutron converter. New excited levels in the daughter /sup 47/K nucleus corresponding to the negative-parity states were observed. The obtained data are compared to the result of large-scale shell model calculations and quasiparticle random-phase approximation predictions. (29 refs).

  12. Interactions between beta subunits of the KCNMB family and Slo3: beta4 selectively modulates Slo3 expression and function.

    Directory of Open Access Journals (Sweden)

    Cheng-Tao Yang

    2009-07-01

    Full Text Available The pH and voltage-regulated Slo3 K(+ channel, a homologue of the Ca(2+- and voltage-regulated Slo1 K(+ channel, is thought to be primarily expressed in sperm, but the properties of Slo3 studied in heterologous systems differ somewhat from the native sperm KSper pH-regulated current. There is the possibility that critical partners that regulate Slo3 function remain unidentified. The extensive amino acid identity between Slo3 and Slo1 suggests that auxiliary beta subunits regulating Slo1 channels might coassemble with and modulate Slo3 channels. Four distinct beta subunits composing the KCNMB family are known to regulate the function and expression of Slo1 Channels.To examine the ability of the KCNMB family of auxiliary beta subunits to regulate Slo3 function, we co-expressed Slo3 and each beta subunit in heterologous expression systems and investigated the functional consequences by electrophysiological and biochemical analyses. The beta4 subunit produced an 8-10 fold enhancement of Slo3 current expression in Xenopus oocytes and a similar enhancement of Slo3 surface expression as monitored by YFP-tagged Slo3 or biotin labeled Slo3. Neither beta1, beta2, nor beta3 mimicked the ability of beta4 to increase surface expression, although biochemical tests suggested that all four beta subunits are competent to coassemble with Slo3. Fluorescence microscopy from beta4 KO mice, in which an eGFP tag replaced the deleted exon, revealed that beta4 gene promoter is active in spermatocytes. Furthermore, quantitative RT-PCR demonstrated that beta4 and Slo3 exhibit comparable mRNA abundance in both testes and sperm.These results argue that, for native mouse Slo3 channels, the beta4 subunit must be considered as a potential interaction partner and, furthermore, that KCNMB subunits may have functions unrelated to regulation of the Slo1 alpha subunit.

  13. In vitro digestibility of beta-casein and beta-lactoglobulin under simulated human gastric and duodenal conditions: A multi-laboratory evaluation

    DEFF Research Database (Denmark)

    Mandalari, G.; Adel-Patient, K.; Barkholt, Vibeke

    2009-01-01

    Initially the resistance to digestion of two cow's milk allergens, beta-casein, and beta-lactoglobulin (beta-Lg), was compared using a "high-protease assay" and a "low-protease assay" in a single laboratory. The low-protease assay represents an alternative standardised protocol mimicking conditions...... found in the gastrointestinal tract. For the high-protease assay, both proteins were incubated with either pepsin or pancreatin and digestion monitored by sodium dodecyl sulphate-polyacrylamide gel electrophoresis and reverse phase-high performance liquid chromatography. The low-protease assay involved...... gastroduodenal digestion in the presence or absence of phosphatidylcholine (PC). Both beta-casein and beta-Lg were susceptible to hydrolysis by pepsin and pancreatin in the high-protease assay. In contrast, the kinetics of beta-casein digestion in the low-protease assay were slower, beta-Lg being pepsin...

  14. Energy Calibration of a Silicon Detector Using Pure Beta-Emitters

    International Nuclear Information System (INIS)

    Borras, C.; Arcos, J. M. los

    1992-01-01

    Energy calibration of SI detectors used in electron spectroscopy 13 commonly performed with conversion electron sources or monoenergetic electrons beams, which are preferred against beta emitters due to the problems arising from their continuous spectra. This paper presents a simple calibration procedure for a PIP-type silicon detector, using 14C, 147Pm, 99 T c and 45Ca sources, that is based on the correspondence between the average channel observed in the experimental spectrum and the mean energy evaluated from the theoretical Fermi distribution for each nuclide. First, a method for evaluating the average channel in the experimental spectrum distorted by the electronic noise is described and its uncertainty estimated. Then, the channel-energy relation ship is established by least squares fitting modified to account for uncertainties in both variables.The calibration has been successfully verified with 147Pm and '09cd sources, showing discrepaneles not greater than 2.5%, within the uncertainties due to the detector resolution and the sources features. (Author)

  15. Murrayafoline A attenuates the Wnt/{beta}-catenin pathway by promoting the degradation of intracellular {beta}-catenin proteins

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Hyuk; Gwak, Jungsug; Cho, Munju; Ryu, Min-Jung [PharmacoGenomics Research Center, Inje University, Busan 614-735 (Korea, Republic of); Lee, Jee-Hyun; Kim, Sang Kyum; Kim, Young Ho [College of Pharmacy, Chungnam National University, Daejeon 305-764 (Korea, Republic of); Lee, Gye Won [Department of Pharmaceutical Engineering, Konyang University, Nonsan 320-711 (Korea, Republic of); Yun, Mi-Young [Department of Beauty Health Care, Daejeon University, Daejeon 305-764 (Korea, Republic of); Cuong, Nguyen Manh [Institute of Natural Products Chemistry, Vietnam Academy of Science and Technology, Hanoi (Viet Nam); Shin, Jae-Gook [PharmacoGenomics Research Center, Inje University, Busan 614-735 (Korea, Republic of); Song, Gyu-Yong, E-mail: gysong@cnu.ac.kr [College of Pharmacy, Chungnam National University, Daejeon 305-764 (Korea, Republic of); Oh, Sangtaek, E-mail: ohsa@inje.ac.kr [PharmacoGenomics Research Center, Inje University, Busan 614-735 (Korea, Republic of)

    2010-01-01

    Molecular lesions in Wnt/{beta}-catenin signaling and subsequent up-regulation of {beta}-catenin response transcription (CRT) occur frequently during the development of colon cancer. To identify small molecules that suppress CRT, we screened natural compounds in a cell-based assay for detection of TOPFalsh reporter activity. Murrayafoline A, a carbazole alkaloid isolated from Glycosmis stenocarpa, antagonized CRT that was stimulated by Wnt3a-conditioned medium (Wnt3a-CM) or LiCl, an inhibitor of glycogen synthase kinase-3{beta} (GSK-3{beta}), and promoted the degradation of intracellular {beta}-catenin without altering its N-terminal phosphorylation at the Ser33/37 residues, marking it for proteasomal degradation, or the expression of Siah-1, an E3 ubiquitin ligase. Murrayafoline A repressed the expression of cyclin D1 and c-myc, which is known {beta}-catenin/T cell factor (TCF)-dependent genes and thus inhibited the proliferation of various colon cancer cells. These findings indicate that murrayafoline A may be a potential chemotherapeutic agent for use in the treatment of colon cancer.

  16. Coexistence of beta 1- and beta 2-adrenoceptors in the rabbit heart: quantitative analysis of the regional distribution by (-)-/sup 3/H-dihydroalprenolol binding

    Energy Technology Data Exchange (ETDEWEB)

    Brodde, O.E.; Leifert, F.J.; Krehl, H.J.

    1982-01-01

    We determined the amount of beta 1- and beta 2-adrenoceptors in right and left atria and ventricles of rabbits. For this purpose inhibition of specific (-)-/sup 3/H-dihydroalprenolol ((-)-/sup 3/H-DHA) binding (5 nM) by beta 1-selective (practolol, metoprolol) and beta 2-selective (zinterol, IPS 339) adrenergic drugs was determined and analyzed by pseudo-Scatchard (Hofstee) plots. For both atria, inhibition of binding by the four selective beta-adrenergic drugs resulted in non-linear Hofstee plots, suggesting the coexistence of both beta-adrenoceptor subtypes. From these plots we calculated a beta 1:beta 2-adrenoceptor ratio of 72:28 for the right atrium and of 82:18 for the left. In contrast, only a very small amount of beta 2-adrenoceptors (approximately 5-7% of the total beta-adrenoceptor population) could be detected in the ventricles. For comparison we analyzed the inhibition of specific (-)-/sup 3/H-DHA binding in tissues with homogeneous population of beta-adrenoceptors (beta 1:guinea pig left ventricle; beta 2: cerebellum of mature rats). For both tissues the four selective beta-adrenergic drugs showed linear Hofstee plots, demonstrating that in tissues with homogeneous beta-receptor population interaction of each drug with the receptor followed simple mass-action kinetics. We conclude that beta 1- and beta 2-adrenoceptors coexist in rabbit atria while the ventricles are predominantly endowed the beta 1-adrenoceptors.

  17. The GSF secondary standard dosimetry laboratory for photon and beta radiation

    International Nuclear Information System (INIS)

    Eckerl, H.; Nahrstedt, U.

    1986-03-01

    A brief outline of the laboratory's tasks and a detailed description of its layout and equipment is given. The laboratory contains a Co-60 irradiation unit, a Cs-137 irradiation unit, a panoramic irradiation unit for different nuclide sources, a 160- and 420 kV X-ray unit, a beta-irradiation unit and a measuring and control room. The calibration laboratory is equipped with reference and field dosemeters. (DG)

  18. Development and applications of beta and near beta titanium alloys

    International Nuclear Information System (INIS)

    Takemura, A.; Ohyama, H.; Nishimura, T.; Abumiya, T.

    1993-01-01

    In this report the authors introduced application of beta and near beta titanium alloys also development and processing of these alloys at Kobe Steel LTD. Ti-15Mo-5Zr-3Al is an alloy developed by Kobe Steel which has been applied for variety of sporting goods, also used as an erosion shield of steam turbine blades. Ti-15Mo-5Zr-3Al high strength wire for valve springs is under development. New beta alloys(Ti-V-Nb-Sn-Al) are under development which have lower flow stress at room temperature than Ti 15V-3Cr-3Sn-3Al, expected to improve productivity of cold forging. NNS forging and thermo mechanical treatment of Ti-10V-2Fe-3Al were studied. Ti-10V-2Fe3Al steam turbine blades and structural parts for aircraft were developed. Fine grain cold strips of Ti 15V-3Cr-3Sn-3Al are produced by annealing and pickling process. These cold strips are used for parts of a fishing rod

  19. BETASCAN: probable beta-amyloids identified by pairwise probabilistic analysis.

    Directory of Open Access Journals (Sweden)

    Allen W Bryan

    2009-03-01

    Full Text Available Amyloids and prion proteins are clinically and biologically important beta-structures, whose supersecondary structures are difficult to determine by standard experimental or computational means. In addition, significant conformational heterogeneity is known or suspected to exist in many amyloid fibrils. Recent work has indicated the utility of pairwise probabilistic statistics in beta-structure prediction. We develop here a new strategy for beta-structure prediction, emphasizing the determination of beta-strands and pairs of beta-strands as fundamental units of beta-structure. Our program, BETASCAN, calculates likelihood scores for potential beta-strands and strand-pairs based on correlations observed in parallel beta-sheets. The program then determines the strands and pairs with the greatest local likelihood for all of the sequence's potential beta-structures. BETASCAN suggests multiple alternate folding patterns and assigns relative a priori probabilities based solely on amino acid sequence, probability tables, and pre-chosen parameters. The algorithm compares favorably with the results of previous algorithms (BETAPRO, PASTA, SALSA, TANGO, and Zyggregator in beta-structure prediction and amyloid propensity prediction. Accurate prediction is demonstrated for experimentally determined amyloid beta-structures, for a set of known beta-aggregates, and for the parallel beta-strands of beta-helices, amyloid-like globular proteins. BETASCAN is able both to detect beta-strands with higher sensitivity and to detect the edges of beta-strands in a richly beta-like sequence. For two proteins (Abeta and Het-s, there exist multiple sets of experimental data implying contradictory structures; BETASCAN is able to detect each competing structure as a potential structure variant. The ability to correlate multiple alternate beta-structures to experiment opens the possibility of computational investigation of prion strains and structural heterogeneity of amyloid

  20. Specific radioimmunoassay of human. beta. -endorphin in unextracted plasma

    Energy Technology Data Exchange (ETDEWEB)

    Wiedemann, E. (Univ. of California, Berkeley); Saito, T.; Linfoot, J.A.; Li, C.H.

    1979-09-01

    With an antiserum against human ..beta..-endorphin (..beta..-EP) crossreacting <2% with human ..beta..-lipotropin (..beta..-LPH) by weight we have developed a radioimmunoassay that can detect 1 pg ..beta..-EP in diluted raw plasma. In a.m. fasting plasma of 14 normal subjects ..beta..-EP ranged from <5 to 45 pg/ml. ..beta..-EP was elevated in untreated, but normal in successfully treated Cushing's disease; undetectable in a patient with adrenal adenoma; extremely high in Nelson's syndrome; and elevated in a patient with bronchogenic carcinoma before, but undetectable after tumor resection. In subjects with intact hypothalamic-pituitary-adrenal axis, ..beta..-EP was undectectable after dexamethasone and increased after metyrapone administration and insulin-induced hypoglycemia. ..beta..-EP concentration was considerably lower in serum than in simultaneously collected plasma, but increased in serum left unfrozen for several hours after clot removal. Thus, ..beta..-EP behaves like a hormone responding to the same stimuli as ACTH and ..beta..-LPH and blood appears to contain enzymes both generating and destroying immunoreactive ..beta..-EP.

  1. Research and development of a beta skin-dose monitor using silicon detectors

    International Nuclear Information System (INIS)

    Chung Manho.

    1991-01-01

    The purpose of the research is to develop improved ways to computer and measure the beta skin dose. Beta spectra for the various sources were calculated based on the Fermi beta decay theory. The calculated average energies of the spectra agreed with the literature values within 6%. Monte Carlo electron transport codes have been developed for use on microcomputers. The one-dimensional code ZEBRA has been converted to a microcomputer version called Eltran2 which runs on the Macintosh or any IBM compatible microcomputers. Eltran2 has then been modified into a two-dimensional program called Eltran3. Using Eltran2 and Eltran3, different source distributions and the hot particle dose have been studied. It has been found that the VARSKIN code overestimates the skin dose from hot particles by about 10 to 40% in comparison with Eltran3 calculations, because the VARSKIN code is based on the data tables for an unbounded medium. An ion-implanted silicon detector was selected because of its small size, high sensitivity, and low leakage current. To cover a wide range of dose rate, both the pulse and current mode operations of the silicon detector were used, with an overlap of one order of magnitude in the measurable dose rate ranges. By using a gradient shield of about 7 mg/cm 2 on the detector, dose gradient measurements have been performed. Five 60 Co hot particles received from GPU Nuclear Corporation have been measured by the silicon detector and the measurements agreed well with Eltran3 calculations. In the pulse mode, variation of the depletion depth of the silicon detector due to the changes of bias voltage was confirmed. Based on this research, a prototype beta skin dose monitor has been constructed. The device includes an 8-bit analogue-to-digital converter and a Z-80 microprocessor with a machine-coded program, to calculate the skin dose

  2. The potential role of SOCS-3 in the interleukin-1beta-induced desensitization of insulin signaling in pancreatic beta-cells

    DEFF Research Database (Denmark)

    Emanuelli, Brice; Glondu, Murielle; Filloux, Chantal

    2004-01-01

    insulin signaling is required for the optimal beta-cell function, we assessed the effect of IL-1beta on the insulin pathway in a rat pancreatic beta-cell line. We show that IL-1beta decreases insulin-induced tyrosine phosphorylation of the insulin receptor (IR) and insulin receptor substrate (IRS...

  3. Molecular analysis of the beta-thalassemia phenotype associated with inheritance of hemoglobin E (alpha 2 beta2(26)Glu leads to Lys).

    OpenAIRE

    Benz, E J; Berman, B W; Tonkonow, B L; Coupal, E; Coates, T; Boxer, L A; Altman, A; Adams, J G

    1981-01-01

    Inheritance of the gene for betaE-globin is associated with hypochromia and microcytosis, reminiscent of typical heterozygous beta-thalassemia. Patients with hemoglobin (Hb)E-beta-thalassemia exhibit clinical phenotypes of severe beta-thalassemia, a circumstance not encountered in other compound heterozygous states for structural beta-chain mutations and beta-thalassemia. We have analyzed the kinetics of globin synthesis and the levels of globin messenger (m) RNA accumulation in patients with...

  4. Lack of systematic topographic difference between attention and reasoning beta correlates.

    Directory of Open Access Journals (Sweden)

    Luis F H Basile

    Full Text Available Based on previous evidence for individual-specific sets of cortical areas active during simple attention tasks, in this work we intended to perform within individual comparisons of task-induced beta oscillations between visual attention and a reasoning task. Since beta induced oscillations are not time-locked to task events and were first observed by Fourier transforms, in order to analyze the cortical topography of attention induced beta activity, we have previously computed corrected-latency averages based on spontaneous peaks of band-pass filtered epochs. We then used Independent Component Analysis (ICA only to single out the significant portion of averaged data, above noise levels. In the present work ICA served as the main, exhaustive means for decomposing beta activity in both tasks, using 128-channel EEG data from 24 subjects. Given the previous observed similarity between tasks by visual inspection and by simple descriptive statistics, we now intended another approach: to quantify how much each ICA component obtained in one task could be explained by a linear combination of the topographic patterns from the other task in each individual. Our hypothesis was that the major psychological difference between tasks would not be reflected as important topographic differences within individuals. Results confirmed the high topographic similarity between attention and reasoning beta correlates in that few components in each individual were not satisfactorily explained by the complementary task, and if those could be considered "task-specific", their scalp distribution and estimated cortical sources were not common across subjects. These findings, along with those from fMRI studies preserving individual data and conventional neuropsychological and neurosurgical observations, are discussed in support of a new functional localization hypothesis: individuals use largely different sets of cortical association areas to perform a given task, but those

  5. Retention levels of vegetable extractable beta-carotene preserved in virgin coconut oil and unadulterated honey

    Directory of Open Access Journals (Sweden)

    Mungai, Z. M.,

    2017-06-01

    Full Text Available Dark green leafy vegetables such as Amaranthus spp. are known to be good sources of beta-carotene, a pro-vitamin A carotenoid with highly potent antioxidant property. As an antioxidant, beta-carotene scavenges for electron and thus terminates chain reactions, prevents recurrence and formation of unstable oxygen which otherwise initiate a chain reaction leading to such cases as cancer. While beta-carotene is supplied from consuming vegetables to provide vitamin A, it is also given as a supplement in cases of deficiency. However, it is highly degraded in the presence of light, heat, and oxygen posing a challenge to the methods of its preservation. Coconut oil and honey are popularly consumed in many countries facing vitamin A deficiency as good antioxidants and yet their role in preservation is largely unknown. The study reports the retention of beta-carotene extracted from Amaranthus spp. and separately preserved in virgin coconut oil (VCO and unadulterated honey for up to six months. HPLC and DPPH assay were used to determine beta-carotene and antioxidant activity respectively. Virgin coconut oil and honey had significantly different (p<0.001 antioxidant activities of 65.12±0.70 and 81.51±1.39 % radical scavenging activity respectively that compared well with those of BHT and ascorbic acid. The concentration of beta-carotene preserved in VCO and unadulterated honey degraded by 90%, though the final retention provided higher than the recommended daily allowance of retinol (0.216±0.001 and 0.312±0.003 retinol activity equivalent respectively when 100 mg is consumed. Virgin coconut oil and unadulterated honey can preserve beta-carotene if high amounts are used.

  6. Automation of electrostatic and magnetic beta-spectrometers; Avtomatizatsiya ehlektrostaticheskogo i magnitnogo {beta}-spektrometra

    Energy Technology Data Exchange (ETDEWEB)

    Sidorov, V T; Petev, P A

    1996-12-31

    Paper describes control units of voltage and current NM respectively, for electrostatic and magnetic beta-spectrometers. These units may be designed on the basis of either SPELMAN company voltage devider ensuring 0.5 accuracy or using a computer modification of feedback. Software for automated electrostatic beta-spectrometer made according to CAMAC standards is considered. 5 figs.

  7. Experiments on double beta decay

    Energy Technology Data Exchange (ETDEWEB)

    Busto, J [Neuchatel Univ. (Switzerland). Inst. de Physique

    1996-11-01

    The Double Beta Decay, and especially ({beta}{beta}){sub 0{nu}} mode, is an excellent test of Standard Model as well as of neutrino physics. From experimental point of view, a very large number of different techniques are or have been used increasing the sensitivity of this experiments quite a lot (the factor of 10{sup 4} in the last 20 years). In future, in spite of several difficulties, the sensitivity would be increased further, keeping the interest of this very important process. (author) 4 figs., 5 tabs., 21 refs.

  8. Maternal and cord plasma concentrations of beta-lipotrophin, beta-endorphin and gamma-lipotrophin at delivery; effect of analgesia.

    Science.gov (United States)

    Browning, A J; Butt, W R; Lynch, S S; Shakespear, R A; Crawford, J S

    1983-12-01

    Maternal venous plasma concentrations of beta-LPH, beta-EP and gamma-LPH were compared in (i) patients undergoing vaginal delivery, 11 with an epidural block and 13 with pethidine and nitrous oxide or no analgesics; (ii) patients delivered by caesarean section, 7 under epidural block and 8 under general anaesthesia. Patients delivered by either method under epidural block had significantly lower levels of all three peptides than those receiving no epidural. There were significant negative correlations between umbilical vein beta-LPH, beta-EP and gamma-LPH concentrations and umbilical artery pH and positive correlations between beta-LPH and beta-EP but not gamma-LPH and cord PCO2 in 29 patients. There was no relation between cord levels of any of the three peptides and the method of analgesia or the route of delivery. Although concentrations of all three peptides were closely correlated to one another in either maternal or cord plasma, there was no relationship between maternal and fetal levels.

  9. Abstraction Mechanisms in the BETA Programming Language

    DEFF Research Database (Denmark)

    Kristensen, Bent Bruun; Madsen, Ole Lehrmann; Møller-Pedersen, Birger

    1983-01-01

    . It is then necessary that the abstraction mechanisms are powerful in order to define more specialized constructs. BETA is an object oriented language like SIMULA 67 ([SIMULA]) and SMALLTALK ([SMALLTALK]). By this is meant that a construct like the SIMULA class/subclass mechanism is fundamental in BETA. In contrast......]) --- covering both data, procedural and control abstractions, substituting constructs like class, procedure, function and type. Correspondingly objects, procedure activation records and variables are all regarded as special cases of the basic building block of program executions: the entity. A pattern thus......The BETA programming language is developed as part of the BETA project. The purpose of this project is to develop concepts, constructs and tools in the field of programming and programming languages. BETA has been developed from 1975 on and the various stages of the language are documented in [BETA...

  10. Prediction of beta-turns with learning machines.

    Science.gov (United States)

    Cai, Yu-Dong; Liu, Xiao-Jun; Li, Yi-Xue; Xu, Xue-biao; Chou, Kuo-Chen

    2003-05-01

    The support vector machine approach was introduced to predict the beta-turns in proteins. The overall self-consistency rate by the re-substitution test for the training or learning dataset reached 100%. Both the training dataset and independent testing dataset were taken from Chou [J. Pept. Res. 49 (1997) 120]. The success prediction rates by the jackknife test for the beta-turn subset of 455 tetrapeptides and non-beta-turn subset of 3807 tetrapeptides in the training dataset were 58.1 and 98.4%, respectively. The success rates with the independent dataset test for the beta-turn subset of 110 tetrapeptides and non-beta-turn subset of 30,231 tetrapeptides were 69.1 and 97.3%, respectively. The results obtained from this study support the conclusion that the residue-coupled effect along a tetrapeptide is important for the formation of a beta-turn.

  11. Ranking beta sheet topologies of proteins

    DEFF Research Database (Denmark)

    Fonseca, Rasmus; Helles, Glennie; Winter, Pawel

    2010-01-01

    One of the challenges of protein structure prediction is to identify long-range interactions between amino acids. To reliably predict such interactions, we enumerate, score and rank all beta-topologies (partitions of beta-strands into sheets, orderings of strands within sheets and orientations...... of paired strands) of a given protein. We show that the beta-topology corresponding to the native structure is, with high probability, among the top-ranked. Since full enumeration is very time-consuming, we also suggest a method to deal with proteins with many beta-strands. The results reported...... in this paper are highly relevant for ab initio protein structure prediction methods based on decoy generation. The top-ranked beta-topologies can be used to find initial conformations from which conformational searches can be started. They can also be used to filter decoys by removing those with poorly...

  12. T Cell-Mediated Beta Cell Destruction: Autoimmunity and Alloimmunity in the Context of Type 1 Diabetes

    Directory of Open Access Journals (Sweden)

    Adam L. Burrack

    2017-12-01

    Full Text Available Type 1 diabetes (T1D results from destruction of pancreatic beta cells by T cells of the immune system. Despite improvements in insulin analogs and continuous blood glucose level monitoring, there is no cure for T1D, and some individuals develop life-threatening complications. Pancreas and islet transplantation have been attractive therapeutic approaches; however, transplants containing insulin-producing cells are vulnerable to both recurrent autoimmunity and conventional allograft rejection. Current immune suppression treatments subdue the immune system, but not without complications. Ideally a successful approach would target only the destructive immune cells and leave the remaining immune system intact to fight foreign pathogens. This review discusses the autoimmune diabetes disease process, diabetic complications that warrant a transplant, and alloimmunity. First, we describe the current understanding of autoimmune destruction of beta cells including the roles of CD4 and CD8 T cells and several possibilities for antigen-specific tolerance induction. Second, we outline diabetic complications necessitating beta cell replacement. Third, we discuss transplant recognition, potential sources for beta cell replacement, and tolerance-promoting therapies under development. We hypothesize that a better understanding of autoreactive T cell targets during disease pathogenesis and alloimmunity following transplant destruction could enhance attempts to re-establish tolerance to beta cells.

  13. Strain-dependent differences in sensitivity of rat beta-cells to interleukin 1 beta in vitro and in vivo

    DEFF Research Database (Denmark)

    Reimers, J I; Andersen, H U; Mauricio, D

    1996-01-01

    /kg) or vehicle for 5 days. All the strains investigated were susceptible to IL-1 beta-induced changes in body weight, food intake, temperature, and plasma glucagon and corticosterone. However, IL-1 beta induced hyperglycemia and impairment of beta-cell glucose responsiveness in WK/Mol and LS/Mol rats...

  14. Techniques involved in the preparation of radioluminescent sources with promethium-147 and gaseous tritium radionuclides

    International Nuclear Information System (INIS)

    Seshadri, N.K.; Subramanian, T.K.; Ravi, S.; Mathew, K.M.; Chinnayan, C.

    2001-01-01

    Beta radiation emanating from promethium-147 and gaseous tritium in close proximity with zinc sulphide phosphor will provide self sustained light sources and are used for, nocturnal illumination of liquid crystal display digital watches and clocks, product advertisements, telephone numbers, exit signs etc. In this paper a procedure for activation of zinc sulphide phosphor with promethium-147 and development of gaseous tritium light sources with respect to thickness of phosphor coating and its effect on light output is described. A typical light source was constructed with promethium-147 activated zinc sulphide to find the overall efficiency of conversion of beta energy to visible light. (author)

  15. Primary and scattering contributions to beta scaled dose point kernels by means of Monte Carlo simulations

    International Nuclear Information System (INIS)

    Valente, Mauro; Botta, Francesca; Pedroli, Guido

    2012-01-01

    Beta-emitters have proved to be appropriate for radioimmunotherapy. The dosimetric characterization of each radionuclide has to be carefully investigated. One usual and practical dosimetric approach is the calculation of dose distribution from a unit point source emitting particles according to any radionuclide of interest, which is known as dose point kernel. Absorbed dose distributions are due to primary and radiation scattering contributions. This work presented a method capable of performing dose distributions for nuclear medicine dosimetry by means of Monte Carlo methods. Dedicated subroutines have been developed in order to separately compute primary and scattering contributions to the total absorbed dose, performing particle transport up to 1 keV or least. Preliminarily, the suitability of the calculation method has been satisfactory, being tested for monoenergetic sources, and it was further applied to the characterization of different beta-minus radionuclides of nuclear medicine interests for radioimmunotherapy. (author)

  16. Feasibility of in situ beta ray measurements in underwater environment.

    Science.gov (United States)

    Park, Hye Min; Park, Ki Hyun; Kang, Sung Won; Joo, Koan Sik

    2017-09-01

    We describe an attempt at the development of an in situ detector for beta ray measurements in underwater environment. The prototype of the in situ detector is based on a CaF2: Eu scintillator using crystal light guide and Si photomultiplier. Tests were conducted using various reference sources for evaluating the linearity and stability of the detector in underwater environment. The system is simple and stable for long-term monitoring, and consumes low power. We show here an effective detection distance of 7 mm and a 2.273 MeV end-point energy spectrum of 90 Sr/ 90 Y when using the system underwater. The results demonstrate the feasibility of in situ beta ray measurements in underwater environment and can be applied for designing an in situ detector for radioactivity measurement in underwater environment. The in situ detector can also have other applications such as installation on the marine monitoring platform and quantitative analysis of radionuclides. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Simulations of Bunch Merging in a Beta Beam Decay Ring

    CERN Document Server

    Heinrich, Daniel Christopher; Chance, Antoine

    2011-01-01

    To further study neutrino oscillation properties a Beta Beam facility has been proposed. Beta decaying ions with high kinetic energy are stored in a storage ring ("Decay Ring") with straight sections to create pure focused (anti) electron neutrino beams. However to reach high sensitivity to neutrino oscillation parameters in the experiment the bunched beam intensity and duty cycle in the DR have to be optimized. The first CERN-based scenario, using 6He and 18Ne as neutrino sources, has been studied using a bunch merging RF scheme. Two RF cavities at different frequencies are used to capture newly injected bunches and then merge them into the stored bunches. It was shown that this scheme could satisfy the requirements on intensity and duty cycle set by the experiment. This merging scheme has now been revised with new simulation software providing new results for 6He and 18Ne. Furthermore bunch merging has been studied for the second CERN-based scenario using 8Li and 8B.

  18. Generating Low Beta Regions with Quadrupoles for Final Muon Cooling

    Energy Technology Data Exchange (ETDEWEB)

    Acosta, J. G. [Mississippi U.; Cremaldi, L. M. [Mississippi U.; Hart, T. L. [Mississippi U.; Oliveros, S. J. [Mississippi U.; Summers, D. J. [Mississippi U.; Neuffer, D. V. [Fermilab

    2017-05-01

    Muon beams and colliders are rich sources of new physics, if muons can be cooled. A normalized rms transverse muon emittance of 280 microns has been achieved in simulation with short solenoids and a betatron function of 3 cm. Here we use ICOOL, G4beamline, and MAD-X to explore using a 400 MeV/c muon beam and strong focusing quadrupoles to approach a normalized transverse emittance of 100 microns and finish 6D muon cooling. The low beta regions produced by the quadrupoles are occupied by dense, low Z absorbers, such as lithium hydride or beryllium, that cool the beam. Equilibrium transverse emittance is linearly proportional to the beta function. Reverse emittance exchange with septa and/or wedges is then used to decrease transverse emittance from 100 to 25 microns at the expense of longitudinal emittance for a high energy lepton collider. Work remains to be done on chromaticity correction.

  19. $\\beta$-delayed fission, laser spectroscopy and shape-coexistence studies with radioactive At beams

    CERN Multimedia

    We propose to study the $\\beta$-delayed fission, laser spectroscopy and radioactive decay of the newly available pure beams of neutron-deficient and neutron-rich astatine (Z=85) isotopes. The fission probability and the fission fragment distribution of the even-even isotopes $^{194,196}$Po following the $\\beta$-decay of the isotopes $^{194,196}$At will be studied with the Windmill setup. In-source laser spectroscopy will be performed on the entire astatine isotopic chain, using a combination of the Windmill setup, ISOLTRAP MR-ToF and ISOLDE Faraday. Radioactive decay data will be acquired at the Windmill setup throughout those studies and contribute to the global understanding of the phenomenon of shape coexistence in the neutron-deficient lead region.

  20. Search for $\\beta$-delayed protons from $^{11}$Be

    CERN Multimedia

    $\\beta$-delayed proton emission from $^{11}$Be will be a very rare process. It is believed to decay directly into continuum states. This would imply that it will be a sensitive probe of the halo structure of the one-neutron halo nucleus $^{11}$Be. We propose to improve existing (unpublished) limits on this decay mode by two orders of magnitude. Our earlier experience at ISOLDE indicates that the required intensity and purity of the source can be obtained. The branching ratio will be measured by counting the number of $^{10}$Be atoms produced via accelerator mass spectrometry.

  1. Selective inhibition of sheep kidney 11 beta-hydroxysteroid dehydrogenase isoform 2 activity by 5 alpha-reduced (but not 5 beta) derivatives of adrenocorticosteroids.

    Science.gov (United States)

    Latif, S A; Sheff, M F; Ribeiro, C E; Morris, D J

    1997-02-01

    We have previously reported that 5 alpha and 5 beta pathways of steroid metabolism are controlled in vivo by dietary Na+ and glycyrrhetinic acid, see Gorsline et al. 1988; Latif et al. 1990. The present investigations provide evidence supporting the suggestion that endogenous substances may regulate the glucocorticoid inactivating isoenzymes, 11 beta-HSD (hydroxysteroid dehydrogenase) 1 (liver) and 11 beta-HSD2 (kidney). The activity of 11 beta-HSD is impaired in essential hypertension, following licorice ingestion, and in patients with apparent mineralocorticoid excess where 11 beta-HSD2 is particularly affected. In all three conditions, excretion of the less common 5 alpha metabolites is elevated in urine. We now report on the differential abilities of a series of Ring A reduced (5 alpha and 5 beta) adrenocorticosteroid and progesterone metabolites to inhibit these isoenzymes. Using liver microsomes with NADP+ as co-factor (11 beta-HSD1), and sheep kidney microsomes with NAD+ as co-factor (11 beta-HSD2), we have systematically investigated the abilities of a number of adrenocorticosteroids and their derivatives to inhibit the individual isoforms of 11 beta-HSD. A striking feature is the differential sensitivity of the two isoenzymes to inhibition by 5 alpha and 5 beta derivatives. 11 beta-HSD1 is inhibited by both 5 alpha and certain 5 beta derivatives. 11 beta-HSD-2 was selectively inhibited only by 5 alpha derivatives: 5 beta derivatives were without inhibitory activity toward this isoform of 11 beta-HSD. These results indicate the importance of the structural conformation of the A and B Rings in conferring specific inhibitory properties on these compounds. In addition, we discuss the effects of additions or substitutions of other functional groups on the inhibitory potency of these steroid molecules against 11 beta-HSD1 and 11 beta-HSD2.

  2. The continuous monitoring of the artificial beta aerosol activity by measuring the alpha and beta activity in aerosol simultaneously

    International Nuclear Information System (INIS)

    Hayakawa, Hironobu; Oonishi, Masaki; Matsuura, Hiroyuki

    1990-01-01

    We have constructed the system to monitor the artificial beta aerosol activity around the nuclear power plants continuously in real time. The smaller releases of artificial radionuclides from the nuclear power plants can be lost in the fluctuations of the natural background of the beta aerosol activity, when only the beta activity of the aerosol is measured. This method to discriminate the artificial and the natural beta activity of the aerosol is based on the fact that the ratio of the natural alpha and beta activities of the aerosol is almost constant. The detection limit of this system is below 3 Bq/m 3 . (author)

  3. Review of present beta dosimetry problems in radiation protection; to day's answers and future trends

    International Nuclear Information System (INIS)

    Fracas, P.

    1986-01-01

    The large use of pure beta radionuclides needs to be develop beta dosimetry methods for radiation protection. The different types of present dosimetry assessments are reviewed. In all the cases the quantity to take into account is the absorbed dose rate in human tissus and more particularly in skin. In the case of point sources of known nature and activity this quantity can be worked out. This calculation is achieved either by incident beta spectrum analysis or theoretical considerations based on Kernel point. The absorbed dose rate can also be measured by extrapolation ionization chamber which characteristics and working are detailed here. All present survey meter were not initially planned for such a beta dosimetry, as this performed with the extrapolation ionization chamber which is taken here as a reference. So responses of usual dosimeters compared to this reference need to be estimated. Responses of personal film badges used in CEA, portable ionization chambers as babyline, pocket dosimeters SEQ7 and the thermoluminescent dosimeters TLD700 are exposed here. Results show that all these survey meters are not completely suitable for routine beta dosimetry. Consequently other operational dosimetry techniques have to be pursued. In particular some thermoluminescence dosimeters for instance boron diffused in surface layer and multi-elements, and furthermore Thermally Stimulated Exoelectron Emission (TSEE) and surface barrier detectors are described [fr

  4. Experimental study on source efficiencies for estimating surface contamination level

    International Nuclear Information System (INIS)

    Ichiji, Takeshi; Ogino, Haruyuki

    2008-01-01

    Source efficiency was measured experimentally for various materials, such as metals, nonmetals, flooring materials, sheet materials and other materials, contaminated by alpha and beta emitter radioactive nuclides. Five nuclides, 147 Pm, 60 Co, 137 Cs, 204 Tl and 90 Sr- 90 Y, were used as the beta emitters, and one nuclide 241 Am was used as the alpha emitter. The test samples were prepared by placing drops of the radioactive standardized solutions uniformly on the various materials using an automatic quantitative dispenser system from Musashi Engineering, Inc. After placing drops of the radioactive standardized solutions, the test materials were allowed to dry for more than 12 hours in a draft chamber with a hood. The radioactivity of each test material was about 30 Bq. Beta rays or alpha rays from the test materials were measured with a 2-pi gas flow proportional counter from Aloka Co., Ltd. The source efficiencies of the metals, nonmetals and sheet materials were higher than 0.5 in the case of contamination by the 137 Cs, 204 Tl and 90 Sr- 90 Y radioactive standardized solutions, higher than 0.4 in the case of contamination by the 60 Co radioactive standardized solution, and higher than 0.25 in the case of contamination by the alpha emitter the 241 Am radioactive standardized solution. These values were higher than those given in Japanese Industrial Standards (JIS) documents. In contrast, the source efficiencies of some permeable materials were lower than those given in JIS documents, because source efficiency varies depending on whether the materials or radioactive sources are wet or dry. This study provides basic data on source efficiency, which is useful for estimating the surface contamination level of materials. (author)

  5. Characterization of beta radiation fields using radiochromic films; Caracterizacao de campos de radiacao beta utilizando filmes radiocromicos

    Energy Technology Data Exchange (ETDEWEB)

    Benavente, Jhonny A.; Silva, Teogenes A. da, E-mail: jabc@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil). Programa de Pos-Graduacao em Ciencia e Tecnologia das Radiacoes, Minerais e Materiais; Meira-Belo, Luiz C.; Reynaldo, Sibele R. [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2011-07-01

    The objective of this work was to study the response of radiochromic films for beta radiation fields in terms of absorbed dose. The reliability of the EBT model Gafchromic radiochromic film was studied. A 9800 XL model Microtek, transmission scanner, a 369 model X-Rite optical densitometer and a Mini 1240 Shimadzu UV spectrophotometer were used for measurement comparisons. Calibration of the three systems was done with irradiated samples of radiochromic films with 0.1; 0.3; 0.5; 0.8; 1.0; 1.5; 2.0; 2.5; 3.0; 3.5; 4.5 e 5.0 Gy in beta radiation field from a Sr-90/Y-90 source. Calibration was performed by establishing a correlation between the absorbed dose values and the corresponding radiochromic responses. Results showed significant differences in the absorbed dose values obtained with the three methods. Absorbed dose values showed errors from 0.6 to 4.4%, 0.3 to 31.8% and 0.2 to 47.3% for the Microtek scanner, the X-Rite Densitometer and the Shimadzu spectrophotometer, respectively. Due to the easy acquisition and use for absorbed dose measurements, the densitometer and the spectrophotometer showed to be suitable techniques to evaluate radiation dose in relatively homogeneous fields. In the case of inhomogeneous fields or for a two dimension mapping of radiation fields to identify anisotropies, the scanner technique is the most recommended. (author)

  6. Beta-lactamases of Mycobacterium tuberculosis and Mycobacterium kansasii.

    Science.gov (United States)

    Segura, C; Salvadó, M

    1997-09-01

    Re-emergence of infectious diseases caused by mycobacteria as well as the emergence of multiresistant strains of Mycobacterium has promoted the research on the use of beta-lactames in the treatment of such diseases. Mycobacteria produce beta-lactamases: M. tuberculosis produces a wide-spectrum beta-lactamase whose behaviour mimicks those of Gram-negative bacteria. M. kansasii produces also beta-lactamase which can be inhibited by clavulanic acid. An overview on beta-lactamases from both species is reported.

  7. The application of {beta}-ray excitation fluorescence to the measurement of the thickness of deposits and to analysis; Applications de la fluorescence excitee au moyen des rayons {beta} a la mesure des epaisseurs des depots et a l'analyse

    Energy Technology Data Exchange (ETDEWEB)

    Martinelli, P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires; Seibel, G [Institut de Recherches de la Siderurgie Francaise (IRSID), 78 - Saint-Germain-en-Laye (France)

    1961-07-01

    Principles of the method are first outlined and the instrumentation used is described. The different types of radiation detectors are subject of a detailed study. As a source of {beta}-radiation {sup 90}(Sr + Y) was used as well as {sup 147}Pm. Great care was taken to eliminate back-diffused electrons by deflection by a strong permanent magnet. The method was applied to the measurement of the thickness of deposits of Cr, Zn, Sn, Cd and Cu on iron as well as Zn, Cr, Ag and Au on copper and the results obtained are discussed. An attempt was made, to use {beta}-X-ray fluorescence for the analysis of minerals, iron ore and glass and for routine control of Si-Mn, Si-Ca, Fe-Mn and Fe-W. Finally the method of {beta}-X-ray fluorescence is compared with normal-X-ray fluorescence and possibilities of further development are cited. (author) [French] Les principes de la methode et l'instrumentation utilisee sont presentes. On decrit en particulier les detecteurs de rayonnement utilises. Comme source de rayonnement on utilise {sup 90}(Sr + Y) et {sup 147}Pm. Pour eliminer les electrons retrodiffuses on utilise un aimant permanent place sur le trajet du faisceau. La methode est appliquee a la mesure des epaisseurs des depots metalliques tels que le Cr, Zn, Sn, Cd et Cu sur fer et le Zn, Cr, Ag et Au sur cuivre. D'autre part, la fluorescence {beta}-X etait utilisee pour l'analyse des minerais et des verres et pour le controle des alliages Fe-Mn, Fe-W, Si-Mn, Si-Ca. Enfin, on passe a une comparaison entre la fluorescence {beta}-X et la fluorescence X normale et on discute les possibilites d'un developpement futur. (auteur)

  8. Alpha and beta-adrenoceptors in hypertension. I. Cardiac and renal alpha 1-, beta 1-, and beta 2-adrenoceptors in rat models of acquired hypertension

    NARCIS (Netherlands)

    Michel, M. C.; Kanczik, R.; Khamssi, M.; Knorr, A.; Siegl, H.; Beckeringh, J. J.; Brodde, O. E.

    1989-01-01

    To determine whether adrenoceptor changes in genetic hypertension occur primary or secondary to blood pressure elevation, we measured cardiac and renal alpha 1- (by [125I]Be 2254 binding) and beta 1- and beta 2-adrenoceptors (by (-)-[125I]iodocyanopindolol binding) densities in various rat models of

  9. Imaging of alpha(v)beta(3) expression by a bifunctional chimeric RGD peptide not cross-reacting with alpha(v)beta(5).

    Science.gov (United States)

    Zannetti, Antonella; Del Vecchio, Silvana; Iommelli, Francesca; Del Gatto, Annarita; De Luca, Stefania; Zaccaro, Laura; Papaccioli, Angela; Sommella, Jvana; Panico, Mariarosaria; Speranza, Antonio; Grieco, Paolo; Novellino, Ettore; Saviano, Michele; Pedone, Carlo; Salvatore, Marco

    2009-08-15

    To test whether a novel bifunctional chimeric peptide comprising a cyclic Arg-Gly-Asp pentapeptide covalently bound to an echistatin domain can discriminate alpha(v)beta(3) from alpha(v)beta(5) integrin, thus allowing the in vivo selective visualization of alpha(v)beta(3) expression by single-photon and positron emission tomography (PET) imaging. The chimeric peptide was preliminarily tested for inhibition of alpha(v)beta(3)-dependent cell adhesion and competition of 125I-echistatin binding to membrane of stably transfected K562 cells expressing alpha(v)beta(3) (Kalpha(v)beta(3)) or alpha(v)beta(5) (Kalpha(v)beta(5)) integrin. The chimeric peptide was then conjugated with diethylenetriaminepentaacetic acid and labeled with 111In for single-photon imaging, whereas a one-step procedure was used for labeling the full-length peptide and a truncated derivative, lacking the last five C-terminal amino acids, with 18F for PET imaging. Nude mice bearing tumors from Kalpha(v)beta(3), Kalpha(v)beta(5), U87MG human glioblastoma, and A431 human epidermoid cells were subjected to single-photon and PET imaging. Adhesion and competitive binding assays showed that the novel chimeric peptide selectively binds to alpha(v)beta(3) integrin and does not cross-react with alpha(v)beta(5). In agreement with in vitro findings, single-photon and PET imaging studies showed that the radiolabeled chimeric peptide selectively localizes in tumor xenografts expressing alphavbeta3 and fails to accumulate in those expressing alpha(v)beta(5) integrin. When 18F-labeled truncated derivative was used for PET imaging, alphavbeta3- and alpha(v)beta(5)-expressing tumors were visualized, indicating that the five C-terminal amino acids are required to differentially bind the two integrins. Our findings indicate that the novel chimeric Arg-Gly-Asp peptide, having no cross-reaction with alphavbeta5 integrin, allows highly selective alphavbeta3 expression imaging and monitoring.

  10. Measurement of Gross Alpha and Beta Emission Rates from Ceramic Tiles

    International Nuclear Information System (INIS)

    Wudthicharoonpun, Piyasak; Chankow, Nares

    2007-08-01

    Full text: Ceramic tiles normally used to cover floors and walls contain naturally occurring radioactive elements i.e. potassium-40, uranium, thorium and their daughters from raw materials. Thus, radioactivity was dependent upon source of raw materials and the amount used. The objective of this research was to measure gross alpha and beta emission rates to be used as a database for safety assessment and for selection of rooms to measure radioactive radon-222 gas

  11. Silent ischemia and beta-blockade

    DEFF Research Database (Denmark)

    Egstrup, K

    1991-01-01

    and should also be directed at the other coronary artery risk factors of the patients. The effects of beta-blockers, which reduce the duration and frequency of silent ischemic episodes, is well described. The effect is most pronounced in the morning, when the frequency of ischemia is highest......, and the mechanism of action seems mainly mediated through a reduction in myocardial oxygen demand. beta-Blockers have shown effectiveness in both effort-induced angina and mixed angina, and increased anti-ischemic potency may be achieved by combination therapy with a calcium antagonist. Abrupt withdrawal of beta-blockers...

  12. Crystal scintillators for use in check-light source for thermoluminescent systems

    Energy Technology Data Exchange (ETDEWEB)

    Nagpal, J.S.; Sabharwal, S.C.; Chougaonkar, M.P.; Godbole, S.V

    1999-08-11

    Beta ({sup 63}Ni, E{sub max} 0.063 MeV) excited radioluminescence of indigenously grown crystal scintillators CsI(Tl), Bi{sub 4}Ge{sub 3}O{sub 12} and CdWO{sub 4} has been studied for its use in check-light source needed for thermoluminescence systems. Temperature coefficient of the light output over 298-323 K and the beta-induced TL of the scintillators over 298-553 K are reported. (author)

  13. Thermoluminescence studies of Nd doped Bi_4Ge_3O_1_2 crystals irradiated by UV and beta sources

    International Nuclear Information System (INIS)

    Karabulut, Y.; Canimoglu, A.; Ekdal, E.; Ayvacikli, M.; Can, N.; Karali, T.

    2016-01-01

    Thermoluminescence (TL) glow curves of pure and rare earth doped bismuth germanate (BGO) were investigated under UV and beta radiation. The glow curves of pure BGO crystal present different patterns for both kinds of radiation. The TL glow curves of BGO crystals doped with Nd ions are similar to that of pure BGO under UV radiation. The kinetic parameters, kinetic order (b), activation energy (E) and frequency factor (s) of the TL glow curves of pure BGO crystal have been determined by peak shape method. Activation energies of 3 peaks obtained by PS were found to be 1.81, 1.15 and 1.78, respectively. - Highlights: • Thermoluminescence properties of pure and Nd doped BGO crystals. • Irradiated by UV and beta for TL glow curve analysis. • Evaluation of kinetic parameters by PS method.

  14. Towards Alzheimer's beta-amyloid vaccination.

    Science.gov (United States)

    Frenkel, D; Solomon, B

    2001-01-01

    Beta-amyloid pathology, the main hallmark of Alzheimer's disease (AD), has been linked to its conformational status and aggregation. We recently showed that site-directed monoclonal antibodies (mAbs) towards the N-terminal region of the human beta-amyloid peptide bind to preformed beta-amyloid fibrils (Abeta), leading to disaggregation and inhibition of their neurotoxic effect. Here we report the development of a novel immunization procedure to raise effective anti-aggregating amyloid beta-protein (AbetaP) antibodies, using as antigen filamentous phages displaying the only EFRH peptide found to be the epitope of these antibodies. Due to the high antigenicity of the phage no adjuvant is required to obtain high affinity anti-aggregating IgG antibodies in animals model, that exhibit identity to human AbetaP. Such antibodies are able to sequester peripheral AbetaP, thus avoiding passage through the blood brain barrier (BBB) and, as recently shown in a transgenic mouse model, to cross the BBB and dissolve already formed beta-amyloid plaques. To our knowledge, this is the first attempt to use as a vaccine a self-anti-aggregating epitope displayed on a phage, and this may pave the way to treat abnormal accumulation-peptide diseases, such as Alzheimer's disease or other amyloidogenic diseases. Copyright 2001 The International Association for Biologicals.

  15. Hydrolyses of alpha-naphthyl acetate, beta-naphthyl acetate, and acetyl-DL-phenylalanine beta-naphthyl ester

    DEFF Research Database (Denmark)

    Kirkeby, S; Moe, D

    1983-01-01

    Using simultaneous coupling azo dye techniques kidney enzymes active against alpha-naphthyl acetate, beta-naphthyl acetate, and acetyl-DL-phenylalanine beta-naphthyl ester are characterized. The enzymes show identical distribution in the section. The banding patterns in zymograms are the same after...

  16. Cloning and characterization of human liver cytosolic beta-glycosidase

    NARCIS (Netherlands)

    De Graaf, M; Van Veen, IC; Van Der Meulen-Muileman, IH; Gerritsen, WR; Pinedo, HM; Haisma, HJ

    2001-01-01

    Cytosolic beta -glucosidase (EC 3.2.1.21) from mammalian liver is a member of the family 1 glycoside hydrolases and is known for its ability to hydrolyse a range of beta -D-glycosides. including beta -D-glucoside acid beta -D-galactoside. We therefore refer to this enzyme as cytosolic beta

  17. Manufacturing of neutral beam sources at Lawrence Livermore Laboratory

    International Nuclear Information System (INIS)

    Baird, E.D.; Duffy, T.J.; Harter, G.A.; Holland, E.D.; Kloos, W.A.; Pastrone, J.A.

    1979-01-01

    Over 50 neutral beam sources (NBS) of the joint Lawrence Berkeley Laboratory (LBL)/Lawrence Livermore Laboratory (LLL) design have been manufactured, since 1973, in the LLL Neutral Beam Source Facility. These sources have been used to provide start-up and sustaining neutral beams for LLL mirror fusion experiments, including 2XIIB, TMX, and Beta II. Experimental prototype 20-kV and 80-kV NBS have also been designed, built, and tested for the Mirror Fusion Test Facility (MFTF)

  18. Few remarks on the absolute counting of {beta} emitters using 4 {pi} counter; Quelques remarques sur la mesure absolue des emetteurs {beta} au compteur 4 {pi}

    Energy Technology Data Exchange (ETDEWEB)

    Grinberg, B; Le Gallic, Y [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    This study looks to determinate the optimum experimental conditions which allow the best accuracy possible for the absolute counting of {beta} emitters when using a 4 {pi} counter. The study has been done with a 4 {pi} counter using source supports of 30 {mu}m thickness. The associated electronic circuit includes: high-voltage, a 1000 scale and a dead time preafier of 4x10{sup -4} {mu}s. In addition, a coincidence preamplifier - with 1 {mu}s resolution time - was added which permits to count the coincidence between the measuring channels. It compares the measurement accuracy and the absorption correction needed for different source supports including polymers thin films with and without metal coating. (M.P.)

  19. High beta-Lactamase Levels Change the Pharmacodynamics of beta-Lactam Antibiotics in Pseudomonas aeruginosa Biofilms

    DEFF Research Database (Denmark)

    Wang, Hengzhuang; Ciofu, Oana; Yang, Liang

    2013-01-01

    the role of beta-lactamase in the pharmacokinetics (PK) and pharmacodynamics (PD) of ceftazidime and imipenem on P. aeruginosa biofilms. P. aeruginosa PAO1 and its corresponding beta-lactamase-overproducing mutant, PA Delta DDh2Dh3, were used in this study. Biofilms of these two strains in flow chambers......, microtiter plates, and on alginate beads were treated with different concentrations of ceftazidime and imipenem. The kinetics of antibiotics on the biofilms was investigated in vitro by time-kill methods. Time-dependent killing of ceftazidime was observed in PAO1 biofilms, but concentration-dependent killing...... activity of ceftazidime was observed for beta-lactamase-overproducing biofilms of P. aeruginosa in all three models. Ceftazidime showed time-dependent killing on planktonic PAO1 and PA Delta DDh2Dh3. This difference is probably due to the special distribution and accumulation in the biofilm matrix of beta...

  20. Serum 11 beta-hydroxyandrostenedione as an indicator of the source of excess androgen production in women with polycystic ovaries.

    Science.gov (United States)

    Polson, D W; Reed, M J; Franks, S; Scanlon, M J; James, V H

    1988-05-01

    Serum 11 beta-hydroxyandrostenedione levels (11-OHA) were measured in normal women and women with polycystic ovaries (PCO) to assess their value in localizing the source of excessive androgen production in women with PCO. Serum 11-OHA was undetectable (less than 1.5 nmol/L) in an adrenalectomized woman, a woman with 11-hydroxylase deficiency, and a woman receiving chronic dexamethasone therapy, confirming the specificity of the antiserum used in this study. Serum 11-OHA concentrations were similar in normal women [mean, 5.0 +/- 2.3 (+/- SD) nmol/L] and women with PCO (5.0 +/- 2.1 nmol/L); serum androstenedione concentrations were increased in women with PCO. Thus, the ratio of androstenedione to 11-OHA was significantly higher (P less than 0.001) in women with PCO (2.0 +/- 0.7) than in normal women (1.1 +/- 0.5). Serum 11-OHA levels after adrenal suppression or stimulation were similar in women with PCO who had an ovulatory response and those who failed to ovulate after clomiphene administration. Administration of dexamethasone (1 mg) and injection of ACTH (250 micrograms) were associated with marked suppression and subsequent stimulation of serum 11-OHA levels in both normal women and women with PCO, and the responses were similar in the two groups. Also, the hour to hour and diurnal variations in serum 11-OHA were similar to those of androstenedione and cortisol during a 24-h period, indicating the adrenal origin of 11-OHA. Our finding of similar serum 11-OHA levels in the presence of increased serum androstenedione levels in women with PCO supports the concept that the ovary is the major source of excess androgen production in women with PCO.

  1. Characterization of a Full-Length Endogenous Beta-Retrovirus, EqERV-Beta1, in the Genome of the Horse (Equus caballus

    Directory of Open Access Journals (Sweden)

    Antoinette C. van der Kuyl

    2011-06-01

    Full Text Available Information on endogenous retroviruses fixed in the horse (Equus caballus genome is scarce. The recent availability of a draft sequence of the horse genome enables the detection of such integrated viruses by similarity search. Using translated nucleotide fragments from gamma-, beta-, and delta-retroviral genera for initial searches, a full-length beta-retrovirus genome was retrieved from a horse chromosome 5 contig. The provirus, tentatively named EqERV-beta1 (for the first equine endogenous beta-retrovirus, was 10434 nucleotide (nt in length with the usual retroviral genome structure of 5’LTR-gag-pro-pol-env-3’LTR. The LTRs were 1361 nt long, and differed approximately 1% from each other, suggestive of a relatively recent integration. Coding sequences for gag, pro and pol were present in three different reading-frames, as common for beta-retroviruses, and the reading frames were completely open, except that the env gene was interrupted by a single stopcodon. No reading frame was apparent downstream of the env gene, suggesting that EqERV-beta1 does not encode a superantigen like mouse mammary tumor virus (MMTV. A second proviral genome of EqERV-beta1, with no stopcodon in env, is additionally integrated on chromosome 5 downstream of the first virus. Single EqERV-beta1 LTRs were abundantly present on all chromosomes except chromosome 24. Phylogenetically, EqERV-beta1 most closely resembles an unclassified retroviral sequence from cattle (Bos taurus, and the murine beta-retrovirus MMTV.

  2. International Society of Sports Nutrition Position Stand: beta-hydroxy-beta-methylbutyrate (HMB)

    OpenAIRE

    Wilson, Jacob M; Fitschen, Peter J; Campbell, Bill; Wilson, Gabriel J; Zanchi, Nelo; Taylor, Lem; Wilborn, Colin; Kalman, Douglas S; Stout, Jeffrey R; Hoffman, Jay R; Ziegenfuss, Tim N; Lopez, Hector L; Kreider, Richard B; Smith-Ryan, Abbie E; Antonio, Jose

    2013-01-01

    Abstract Position Statement: The International Society of Sports Nutrition (ISSN) bases the following position stand on a critical analysis of the literature on the use of beta-hydroxy-beta-methylbutyrate (HMB) as a nutritional supplement. The ISSN has concluded the following. 1. HMB can be used to enhance recovery by attenuating exercise induced skeletal muscle damage in trained and untrained populations. 2. If consuming HMB, an athlete will benefit from consuming the supplement in close pro...

  3. Evaluation of blue light exposure to beta brainwaves on simulated night driving

    Science.gov (United States)

    Purawijaya, Dandri Aly; Fitri, Lulu Lusianti; Suprijanto

    2015-09-01

    Numbers of night driving accident in Indonesia since 2010 are exponentially rising each year with total of loss more than 50 billion rupiah. One of the causes that contribute to night driving accident is drowsiness. Drowsiness is affected by circadian rhythm resulted from the difference of blue light quality and quantity between night and day. Blue light may effect on human physiology through non-visual pathway by suppressing melatonin hormone suppression that influence drowsiness. Meanwhile, the production of hormones and other activities in brain generate bioelectrical activity such as brainwaves and can be recorded using Electroencephalograph (EEG). Therefore, this research objective is to evaluate the effect of blue light exposure to beta brainwave emergence during night driving simulation to a driver. This research was conducted to 4 male subjects who are able to drive and have a legitimate car driving license. The driving simulator was done using SCANIA Truck Driving Simulator on freeform driving mode in dark environment. Subjects drove for total 32 minutes. The data collections were taken in 2 days with 16 minutes for each day. The 16 minutes were divided again into 8 minutes adaptation in dark and 8 minutes for driving either in blue light exposure or in total darkness. While driving the simulation, subjects' brainwaves were recorded using EEG EMOTIV 14 Channels, exposed by LED monochromatic blue light with 160 Lux from source and angle 45o and sat 1 m in front of the screen. Channels used on this research were for visual (O1; O2), cognition (F3; F4; P7; P8), and motor (FC5; FC6). EEG brainwave result was filtered with EEGLab to obtain beta waves at 13 - 30 Hz frequencies. Results showed that beta waves response to blue light varied for each subject. Blue light exposure either increased or decreased beta waves in 2 minutes pattern and maintaining beta waves on cognition and motor area in 3 out of 4 subjects. Meanwhile, blue light exposure did not maintain

  4. Role of the nitric oxide/cyclic GMP/Ca2+ signaling pathway in the pyrogenic effect of interleukin-1beta.

    Science.gov (United States)

    Palmi, Mitri; Meini, Antonella

    2002-04-01

    Interleukin-1beta (IL-1beta) has a wide spectrum of inflammatory, metabolic, haemopoietic, and immunological properties. Because it produces fever when injected into animals and humans, it is considered an endogenous pyrogen. There is evidence to suggest that Ca2+ plays a critical role in the central mechanisms of thermoregulation, and in the intracellular signaling pathways controlling fever induced by IL-1beta and other pyrogens. Data from different labs indicate that Ca2+ and Na+ determine the temperature set point in the posterior hypothalamus (PH) of various mammals and that changes in Ca2+ and PGE2 concentrations in the cerebrospinal fluid (CSF) of these animals are associated with IL-1beta-induced fever. Antipyretic drugs such as acetylsalicylic acid, dexamethasone, and lipocortin 5-(204-212) peptide counteract IL-1beta-induced fever and abolish changes in Ca2+ and PGE2 concentrations in CSF. In vitro studies have established that activation of the nitric oxide (NO)/cyclic GMP (cGMP) pathway is part of the signaling cascade transducing Ca2+ mobilization in response to IL-1beta and that the ryanodine (RY)- and inositol-(1,4,5)-trisphosphate (IP3)-sensitive pools are the main source of the mobilized Ca2+. It is concluded that the NO/cGMP/Ca2+ pathway is part of the signaling cascade subserving some of the multiple functions of IL-1beta.

  5. Structure of beta-diketiminates and beta-aminoketones made from anisidines or chloroanilines: tin and lithium complexes

    Czech Academy of Sciences Publication Activity Database

    Olejník, R.; Padělková, Z.; Horáček, Michal; Růžička, A.

    2012-01-01

    Roč. 35, 1-2 (2012), s. 13-27 ISSN 0334-7575 Institutional support: RVO:61388955 Keywords : beta-diketimines * beta-enaminones * lithium Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 0.207, year: 2011

  6. Beta activity in the premotor cortex is increased during stabilized as compared to normal walking

    Directory of Open Access Journals (Sweden)

    Sjoerd M. Bruijn

    2015-10-01

    Full Text Available Walking on two legs is inherently unstable. Still, we humans perform remarkable well at it, mostly without falling. To gain more understanding of the role of the brain in controlling gait stability we measured brain activity using electro-encephalography (EEG during stabilized and normal walking.Subjects walked on a treadmill in two conditions, each lasting 10 minutes; normal, and while being laterally stabilized by elastic cords. Kinematics of trunk and feet, electro-myography (EMG of neck muscles, as well as 64-channel EEG were recorded. To assess gait stability the local divergence exponent, step width, and trunk range of motion were calculated from the kinematic data. We used independent component analysis to remove movement, EMG, and eyeblink artifacts from the EEG, after which dynamic imaging of coherent sources beamformers were determined to identify cortical sources that showed a significant difference between conditions. Stabilized walking led to a significant increase in gait stability, i.e. lower local divergence exponents. Beamforming analysis of the beta band activity revealed significant sources in bilateral pre-motor cortices. Projection of sensor data on these sources showed a significant difference only in the left premotor area, with higher beta power during stabilized walking, specifically around push-off, although only significant around contralateral push-off. It appears that even during steady gait the cortex is involved in the control of stability.

  7. Topical beta-blockers and mortality

    NARCIS (Netherlands)

    Müskens, Rogier P. H. M.; Wolfs, Roger C. W.; Witteman, Jacqueline C. M.; Hofman, Albert; de Jong, Paulus T. V. M.; Stricker, Bruno H. C.; Jansonius, Nomdo M.

    2008-01-01

    To study the associations between long-term and short-term use of topical beta-blockers and mortality. Prospective population-based cohort study. To examine long-term effects, 3842 participants aged 55 years and older were recruited. To examine short-term effects, 484 incident beta-blocker users and

  8. Predicting Bond Betas using Macro-Finance Variables

    DEFF Research Database (Denmark)

    Aslanidis, Nektarios; Christiansen, Charlotte; Cipollini, Andrea

    We conduct in-sample and out-of-sample forecasting using the new approach of combining explanatory variables through complete subset regressions (CSR). We predict bond CAPM betas and bond returns conditioning on various macro-fi…nance variables. We explore differences across long-term government ...... bonds, investment grade corporate bonds, and high-yield corporate bonds. The CSR method performs well in predicting bond betas, especially in-sample, and, mainly high-yield bond betas when the focus is out-of-sample. Bond returns are less predictable than bond betas....

  9. Central beta-adrenergic modulation of cognitive flexibility.

    Science.gov (United States)

    Beversdorf, David Q; White, Dawn M; Chever, Daquesha C; Hughes, John D; Bornstein, Robert A

    2002-12-20

    Situational stressors and anxiety impede performance on creativity tests requiring cognitive flexibility. Preliminary research revealed better performance on a task requiring cognitive flexibility, the anagram task, after propranolol (beta-adrenergic antagonist) than after ephedrine (beta-adrenergic agonist). However, propranolol and ephedrine have both peripheral and central beta-adrenergic effects. In order to determine whether noradrenergic modulation of cognitive flexibility is a centrally or peripherally mediated phenomenon, we compared the effects of propranolol (peripheral and central beta-blocker), nadolol (peripheral beta-blocker), and placebo on anagram task performance. Solution latency scores for each subject were compared across the drug conditions. Anagram solution latency scores after propranolol were significantly lower than after nadolol. This suggests a centrally mediated modulatory influence of the noradrenergic system on cognitive flexibility.

  10. Beta calibration and dosimetry at IPEN

    International Nuclear Information System (INIS)

    Caldas, L.V.E.

    1983-01-01

    A commercial extrapolation chamber (PTW, Germany) was tested in different beta radiation fields and its properties investigated. Its usefullness for beta radiation calibration and dosimetry was demonstrated. (Author) [pt

  11. Beta adrenoreceptors in the rabbit bladder detrusor muscle

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, G.F.; Marks, B.H.

    1984-02-01

    This study examines the beta adrenergic receptors of the rabbit detrusor smooth muscle, employing (/sup 125/I)iodocyanopindolol (ICYP) as a ligand for the binding of beta adrenergic receptors. Saturation binding experiments on the isolated membrane fraction yielded a KD for ICYP of 14.7 pM and a maximum binding of 147.6 fmol/mg of protein. Displacement of labeled ICYP by a series of beta adrenergic agents yielded the following KD values for the combined high and low affinity binding sites: I-propranolol, 0.76 nM; ICI 118,551, 1.7 nM; zinterol, 38.0 nM; metoprolol, 3.5 microM; and practolol, 61.4 microM. When these displacement experimental results were compared to KD values from other reported binding studies with ICYP for beta adrenoreceptors, both the order of potency and the KD values indicated primarily beta-2 adrenergic receptor subtypes. Computer program Scatfit analysis of the displacement curves indicated a single slope and affinity constant for all five beta adrenergic agents. Hofstee plots for zinterol, ICI 118,551 and metoprolol, however, were not linear and indicated that minor populations of beta-1 adrenoreceptors were also present as both high and low affinity binding sites could be defined. It is concluded that the primary receptor population is beta-2 and that this tissue is heterogenous with a small population of beta-1 adrenoreceptors representing approximately 13 to 23% of the total beta adrenoreceptor population.

  12. Beta adrenoreceptors in the rabbit bladder detrusor muscle

    International Nuclear Information System (INIS)

    Anderson, G.F.; Marks, B.H.

    1984-01-01

    This study examines the beta adrenergic receptors of the rabbit detrusor smooth muscle, employing [ 125 I]iodocyanopindolol (ICYP) as a ligand for the binding of beta adrenergic receptors. Saturation binding experiments on the isolated membrane fraction yielded a KD for ICYP of 14.7 pM and a maximum binding of 147.6 fmol/mg of protein. Displacement of labeled ICYP by a series of beta adrenergic agents yielded the following KD values for the combined high and low affinity binding sites: I-propranolol, 0.76 nM; ICI 118,551, 1.7 nM; zinterol, 38.0 nM; metoprolol, 3.5 microM; and practolol, 61.4 microM. When these displacement experimental results were compared to KD values from other reported binding studies with ICYP for beta adrenoreceptors, both the order of potency and the KD values indicated primarily beta-2 adrenergic receptor subtypes. Computer program Scatfit analysis of the displacement curves indicated a single slope and affinity constant for all five beta adrenergic agents. Hofstee plots for zinterol, ICI 118,551 and metoprolol, however, were not linear and indicated that minor populations of beta-1 adrenoreceptors were also present as both high and low affinity binding sites could be defined. It is concluded that the primary receptor population is beta-2 and that this tissue is heterogenous with a small population of beta-1 adrenoreceptors representing approximately 13 to 23% of the total beta adrenoreceptor population

  13. Reduced Expression of the Liver/Beta-Cell Glucose Transporter Isoform in Glucose-Insensitive Pancreatic Beta Cells of Diabetic Rats

    Science.gov (United States)

    Thorens, Bernard; Weir, Gordon C.; Leahy, John L.; Lodish, Harvey F.; Bonner-Weir, Susan

    1990-09-01

    Rats injected with a single dose of streptozocin at 2 days of age develop non-insulin-dependent diabetes 6 weeks later. The pancreatic beta islet cells of these diabetic rats display a loss of glucose-induced insulin secretion while maintaining sensitivity to other secretagogues such as arginine. We analyzed the level of expression of the liver/beta-cell glucose transporter isoform in diabetic islets by immunofluorescence staining of pancreas sections and by Western blotting of islet lysates. Islets from diabetic animals have a reduced expression of this beta-cell-specific glucose transporter isoform and the extent of reduction is correlated with the severity of hyperglycemia. In contrast, expression of this transporter isoform in liver is minimally modified by the diabetes. Thus a decreased expression of the liver/beta-cell glucose transporter isoform in beta cells is associated with the impaired glucose sensing characteristic of diabetic islets; our data suggest that this glucose transporter may be part of the beta-cell glucose sensor.

  14. Beta spectra. II-Positron spectra

    International Nuclear Information System (INIS)

    Grau, A.; Garcia-Torano, E.

    1981-01-01

    Using the Fermi theory of beta decay, the beta spectra for 30 positron emitters have been computed, introducing a correction factor for unique forbidden transitions. The spectra are ploted vs. energy, once normalised, and tabulated with the related Fermi functions. The average and median energies are calculated. (author)

  15. Beta Blockers

    Science.gov (United States)

    ... may not work as effectively for people of African heritage and older people, especially when taken without ... conditions/high-blood-pressure/in-depth/beta-blockers/ART-20044522 . Mayo Clinic Footer Legal Conditions and Terms ...

  16. Beta-Carotene

    Science.gov (United States)

    ... disease (COPD). It is also used to improve memory and muscle strength. Some people use beta-carotene ... to reduce the chance of death and night blindness during pregnancy, as well as diarrhea and fever ...

  17. Superconducting Prototype Cavities for the Spallation Neutron Source (SNS) Project

    International Nuclear Information System (INIS)

    Ciovati, G.; Kneisel, P.; Brawley, J.; Bundy, R.; Campisi, I.; Davis, K.; Macha, K.; Machie, D.; Mammosser, J.; Morgan, S.; Sundelin, R.; Turlington, L.; Wilson, K.; Doleans, M.; Kim, S.H.; Barni, D.; Pagani, C.; Pierini, P.; Matsumoto, K.; Mitchell, R.; Schrage, D.; Parodi, R.; Sekutowicz, J.; Ylae-Oijala, P.

    2001-01-01

    The Spallation Neutron Source project includes a superconducting linac section in the energy range from 192 MeV to 1000 MeV, operating at a frequency of 805 MHz at 2.1 K. For this energy range two types of cavities are needed with geometrical beta - values of beta= 0.61 and beta= 0.81. An aggressive cavity prototyping program is being pursued at Jlab, which calls for fabricating and testing of four beta= 0.61 cavities and two beta= 0.81 cavities. Both types consist of six cells made from high purity niobium and feature one HOM coupler on each beam pipe and a port for a high power coaxial input coupler. Three of the four beta= 0.61 cavities will be used for a cryomodule test in early 2002. At this time four medium beta cavities and one high beta cavity have been completed at JLab. The first tests on the beta=0.61 cavity and the beta= 0.81 exceeded the design values for gradient and Q - value: E acc = 1 0.3 MV/m and Q = 5 x 10 9 at 2.1K for beta= 0.61 and E acc = 12.3 MV/m and Q = 5 x 10 9 at 2.1K for beta= 0.81. One of the medium beta cavities has been equipped with an integrated helium vessel and measurements of the static and dynamic Lorentz force detuning will be done and compared to the ''bare'' cavities. In addition two single cell cavities have been fabricated, equipped with welded-on HOM couplers. They are being used to evaluate the HOM couplers with respect to multipacting, fundamental mode rejection and HOM damping as far as possible in a single cell. This paper will describe the cavity design with respect to electrical and mechanical features, the fabrication efforts and the results obtained with the different cavities existing at the time of this workshop

  18. Do factors related to combustion-based sources explain ...

    Science.gov (United States)

    Introduction: Spatial heterogeneity of effect estimates in associations between PM2.5 and total non-accidental mortality (TNA) in the United States (US), is an issue in epidemiology. This study uses rate ratios generated from the Multi-City/Multi-Pollutant study (1999-2005) for 313 core-based statistical areas (CBSA) and their metropolitan divisions (MD) to examine combustion-based sources of heterogeneity.Methods: For CBSA/MDs, area-specific log rate ratios (betas) were derived from a model adjusting for time, an interaction with age-group, day of week, and natural splines of current temperature, current dew point, and unconstrained temperature at lags 1, 2, and 3. We assessed the heterogeneity in the betas by linear regression with inverse variance weights, using average NO2, SO2, and CO, which may act as a combustion source proxy, and these pollutants’ correlations with PM2.5. Results: We found that weighted mean PM2.5 association (0.96 percent increase in total non-accidental mortality for a 10 µg/m3 increment in PM2.5) increased by 0.26 (95% confidence interval 0.08 , 0.44) for an interquartile change (0.2) in the correlation of SO2 and PM2.5., but betas showed less dependence on the annual averages of SO2 or NO2. Spline analyses suggest departures from linearity, particularly in a model that examined correlations between PM2.5 and CO.Conclusions: We conclude that correlations between SO2 and PM2.5 as an indicator of combustion sources explains some hete

  19. Hydroxyurea responses in clinically varied beta, HbE-beta thalassaemia and sickle cell anaemia patients of Eastern India.

    Science.gov (United States)

    Chatterjee, Tridip; Chakravarty, Amit; Chakravarty, Sudipa

    2018-05-01

    The haematological and clinical response to hydroxyurea was estimated in HbE-beta, beta thalassaemia and sickle cell anaemia patients of Eastern India, with variable clinical severity and transfusion requirement to determine whether hydroxyurea can help these patients to maintain their steady haemoglobin level without blood transfusions. Three hundred patients (189 HbE-beta thalassaemia, 95 beta thalassaemia and 16 other haemoglobinopathies including sickle cell anaemia) were selected for hydroxyurea therapy and were followed up for 48-60 months. Results suggest significant response to hydroxyurea therapy in 19 beta and 99 HbE-beta patients in the transfusion-dependent group (GR-I). All of them became transfusion-independent while on hydroxyurea therapy. The majority of responding patients were IVS1-5(G-C) in one of their alleles in HbE-beta cases (83 out of 119). Though IVS1-5(G-C) was found to be the commonest mutation in our selected patients, the mutational background of the patients does not found to have any significant correlation with the response category towards hydroxyurea as per the results observed in our study. But, the drug works pretty well in most of the transfusion-dependent patients, as these patients were withdrawn from regular blood transfusion. At the same time, partial or no response to the drug hydroxyurea was also recorded in our study.

  20. Optimization of point sources on thin films using a statistical design approach. Application to {sup 60}Co sources; Optimisation des sources ponctuelles sur film mince par une approche experimentale de type plan d'experiences. Application aux sources de {sup 60}Co

    Energy Technology Data Exchange (ETDEWEB)

    Sanoit, J.; Leprince, B. [CEA Saclay, Dept. d' Instrumentation et de Metrologie des Rayonnements Ionisants, 91 - Gif sur Yvette (France); Vailhen, D. [CEA Saclay, Dir. de la Surete Nucleaire et de la Qualite, 91 - Gif sur Yvette (France)

    2001-07-01

    Radioactive point sources prepared by depositing weighed drops on thin membranes are commonly used in ionizing radiation metrology for 47{pi}{beta}-{gamma} coincidence counting or for low energy electrons spectrometry. The present study deals with the preparation of good quality sources having high detection yields. Some influential parameters on the source quality are studied using {sup 60}Co as radioactive tracer. An approach based on experimental statistical designs has been chosen. This approach allows us to obtain reliable results with a number of experiences lower than in the case of a systematic approach. Homogeneous {sup 60}Co sources with high metrological qualifies (R{sub {beta}}> 96 %) can be prepared using a direct deposit of {approx} 5 mg drops of {sup 60}Co solution ([Co] = 12 {mu}g/g, [HCl] = 0,5 mol/I) and dried at 60 deg C. The support of the radioactive spot is constituted with a gold coated (130 {mu}g/cm{sup 2} of Au) Vyns films (thickness 45 {mu}g/cm{sup 2}) on which a pad (diameter = 7 - 8 mm) of polystyrene microspheres (Estapor K-007) is prepared by an electro-spraying technique under 7,5 kV during 10 minutes. The alcoholic solution used for the electro-spraying step has the following chemical composition [Estapor K-007] 2.5 10{sup -2} wt % and [Tween 20] = 2.7 10{sup -2} wt %. (authors)

  1. Formulary considerations in selection of beta-blockers.

    Science.gov (United States)

    Yedinak, K C

    1993-08-01

    Selection of beta-adrenergic blockers for formulary addition can be a difficult task, especially with the increasing availability of new beta-blockers, as well as the numerous differences in pharmacodynamic and pharmacokinetic properties of currently available agents. Nevertheless, appropriate evaluation of the important characteristics of beta-blockers should allow selection of the most cost-effective agents for formulary addition. Most importantly, differences in efficacy, product formulation and cost should be carefully considered when making formulary decisions. Notably, evidence from clinical trials indicates differences in efficacy among beta-blockers for post-myocardial infarction prophylaxis, situational anxiety, essential tremor, thyrotoxicosis, migraine prophylaxis and prevention of bleeding associated with oesophageal varices. For many clinical situations, it is also important to select an effective agent that is available in both an oral and intravenous formulation, especially for cardioprotection after acute myocardial infarction and for use in supraventricular arrhythmias. In addition, availability of sustained release products and generic formulations should be considered for their potential to increase compliance and decrease cost, respectively. Comparative drug costs, as well as costs associated with decreased compliance, should also be carefully evaluated. Differences in beta-receptor selectivity, duration of action and presence of intrinsic sympathomimetic activity (ISA) are also important considerations in the selection of beta-blockers for formulary consideration. Although degree of selectivity is relative, beta 1-selective agents may be less likely to induce bronchospasm in patients with chronic obstructive pulmonary disease (COPD) and may be less likely to affect glucose homeostasis in patients with diabetes mellitus. Duration of action of a beta-blocker is an important consideration for evaluation of efficacy throughout the recommended

  2. Iodine-123 labelled N-(2-fluoroethyl)-2{beta}-carbomethoxy-3{beta}-(4-iodophenyl)nortropane for dopamine transporter imaging in the living human brain

    Energy Technology Data Exchange (ETDEWEB)

    Kuikka, J.T. [Dept. of Clinical Physiology, Kuopio Univ. Hospital (Finland); AAkerman, K. [Dept. of Clinical Physiology, Kuopio Univ. Hospital (Finland); Bergstroem, K.A. [Dept. of Clinical Physiology, Kuopio Univ. Hospital (Finland); Karhu, J. [Dept. of Clinical Neurophysiology, Kuopio Univ. Hospital (Finland); Hiltunen, J. [MAP Medical Technologies Oy, Tikkakoski (Finland); Haukka, J. [MAP Medical Technologies Oy, Tikkakoski (Finland); Heikkinen, J. [Dept. of Clinical Physiology, Kuopio Univ. Hospital (Finland); Tiihonen, J. [Dept. of Forensic Psychiatry, Niuvanniemi Hospital, Kuopio (Finland); Wang, S. [Research Biochemical International (RBI), Natick, MA (United States); Neumeyer, J.L. [Research Biochemical International (RBI), Natick, MA (United States)

    1995-07-01

    Here we report a pilot comparison of [{sup 123}I]{beta}-CIT and [{sup 123}I]{beta}-CIT-FP with a new tropane derivative, [{sup 123}I]N-(2-fluoroethyl)-2{beta}-carbomethoxy-3{beta}-(4-iodophenyl)nortropane ([{sup 123}I]{beta}-CIT-FE), using SPET imaging in four healthy male subjects. Peak uptake of [{sup 123}I]{beta}-CIT-FE into the basal ganglia occurred very rapidly (0.5 h after injection of tracer), after which the striatal washout obeyed a bi-exponential form. The specific DAT binding of [{sup 123}I]{beta}-CIT-FE into the basal ganglia was somewhat less (0.785{+-}0.117) than that of [{sup 123}I]{beta}-CIT (0.922{+-}0.004) or [{sup 123}I]{beta}-CIT-FP (0.813{+-}0.047). All these tracers have excellent imaging quality in healthy control subjects. However, the relatively fast washout of [{sup 123}I]{beta}-CIT-FE and low temporal resolution of older SPET cameras may limit the use of this tracer to the measurement of the DAT density. (orig./UG)

  3. Synthesis of electroplated 63Ni source and betavoltaic battery

    International Nuclear Information System (INIS)

    Uhm, Young Rang; Yoo, Kwon Mo; Choi, Sang Mu; Kim, Jin Joo; Son, Kwang Jae

    2015-01-01

    Radioisotope (Nuclear) battery using 63 Ni was prepared as beta cell. The electroplated 63 Ni on Ni foil is fabricated, and beta cell and photovoltaic hybrid battery was designed to use at both day and night in space project. A Ni-plating solution is prepared by dissolving metal particles including 62 Ni and 63 Ni from neutron irradiation of (n,γ). Electroplating solution of a chloride bath consists on nickel ions in HCl, H 3 BO 3 , and KOH. The deposition was carried out at current density of 10 mA cm -2 . The prepared beta source was attached on a PN junction and measured I-V properties. The power output at activity of 0.07 mCi and 0.45 mCi were 0.55 pW and 2.69 nW, respectively

  4. Design and optimization of beta-cell temperature sensor based on 63Ni–Si

    International Nuclear Information System (INIS)

    Ghasemi Nejad, Gholam Reza; Rahmani, Faezeh; Abaeiani, Gholam Reza

    2014-01-01

    A theoretical study of the use of a beta-cell as a temperature sensor using MCNP4C Monte Carlo code is presented in this paper. Nickel-63 and silicon were selected as the beta source and semiconductor material, respectively. The maximum open-circuit voltage (V OC ) is equal to 0.445 V with doping concentrations of N A =4×10 18 #/cm 3 and N D =8×10 19 #/cm 3 in the base and the emitter region, respectively, which, depending on the source activity, enables measurement in a wide range of temperature. The effects of the activity and its change over time on V OC were also studied. The results demonstrated that V OC exhibited smaller changes for higher activities. The temperature sensitivity of this sensor ranges from −2.42 mV/K to −3.41 mV/K for source activities from 100 mCi to 0.001 mCi, respectively, so the optimal activity can be determined according to the desired temperature range and sensitivity. - Highlights: • A silicon p–n junction using 63 Ni is used as a temperature sensor. • The rate of electron–hole generation in silicon was simulated using Monte Carlo MCNP4c code. • The effects of the structural properties of the semiconductor, such as doping concentration and the thickness of the emitter, on the sensitivity and temperature range were studied. • The source thickness and the effect of the activity and its change over time on V OC were investigated at various temperatures

  5. Interleukin-1 beta Attenuates Myofibroblast Formation and Extracellular Matrix Production in Dermal and Lung Fibroblasts Exposed to Transforming Growth Factor-beta 1

    NARCIS (Netherlands)

    Mia, Masum M.; Boersema, Miriam; Bank, Ruud A.

    2014-01-01

    One of the most potent pro-fibrotic cytokines is transforming growth factor (TGF beta). TGF beta is involved in the activation of fibroblasts into myofibroblasts, resulting in the hallmark of fibrosis: the pathological accumulation of collagen. Interleukin-1 beta (IL1 beta) can influence the

  6. Calibration of thermoluminescence skin dosemeter response to beta emitters found in Ontario Hydro nuclear power stations

    International Nuclear Information System (INIS)

    Walsh, M.L.; Agnew, D.A.; Donnelly, K.E.

    1984-01-01

    The response of the Ontario Hydro Thermoluminescence Dosimetry System to beta radiation in nuclear power station environments was evaluated. Synthetic beta spectra were constructed, based on activity samples from heat transport systems and fuelling machine contamination smears at nuclear power stations. Using these spectra and dosemeter energy response functions, an overall response factor for the skin dosemeter relative to skin dose at 7 mg.cm -2 was calculated. This calculation was done assuming three specific geometries: (1) an infinite uniformly contaminated plane source at a distance of 33 cm (50 mg.cm -2 total shielding) from the receptor; (2) an infinite cloud surrounding the receptor; (3) a point source at 33 cm. Based on these calculations, a conservative response factor of 0.7 has been chosen. This provides an equation for skin dose assignment, i.e. Skin Dose = 1.4 x Skin Dosemeter Reading when the skin dosemeter is directly calibrated in mGy(gamma). (author)

  7. Metallo-beta-lactamases of Pseudomonas aeruginosa--a novel mechanism resistance to beta-lactam antibiotics.

    Directory of Open Access Journals (Sweden)

    Dorota Olszańska

    2008-06-01

    Full Text Available Since about twenty years, following the introduction into therapeutic of news beta-lactam antibiotics (broad-spectrum cephalosporins, monobactams and carbapenems, a very significant number of new beta-lactamases appeared. These enzymes confer to the bacteria which put them, the means of resisting new molecules. The genetic events involved in this evolution are of two types: evolution of old enzymes by mutation and especially appearance of new genes coming for some, from bacteria of the environment. Numerous mechanisms of enzymatic resistance to the carbapenems have been described in Pseudomonas aeruginosa. The important mechanism of inactivation carbapenems is production variety of b-lactam hydrolysing enzymes associated to carbapenemases. The metallo-beta-enzymes (IMP, VIM, SPM, GIM types are the most clinically significant carbapenemases. P. aeruginosa posses MBLs and seem to have acquired them through transmissible genetic elements (plasmids or transposons associated with integron and can be transmission to other bacteria. They have reported worldwide but mostly from South East Asia and Europe. The enzymes, belonging to the molecular class B family, are the most worrisome of all beta-lactamases because they confer resistance to carbapenems and all the beta-lactams (with the exception of aztreonam and usually to aminoglycosides and quinolones. The dissemination of MBLs genes is thought to be driven by regional consumption of extended--spectrum antibiotics (e.g. cephalosporins and carbapenems, and therefore care must be taken that these drugs are not used unnecessarily.

  8. Covalent labeling of the beta-adrenergic ligand-binding site with para-(bromoacetamidyl)benzylcarazolol. A highly potent beta-adrenergic affinity label

    International Nuclear Information System (INIS)

    Dickinson, K.E.; Heald, S.L.; Jeffs, P.W.; Lefkowitz, R.J.; Caron, M.G.

    1985-01-01

    Para-(Bromoacetamidyl)benzylcarazolol (pBABC) was synthesized and found to be an extremely potent affinity label for beta-adrenergic receptors. Its interaction with mammalian (rabbit and hamster lung) and nonmammalian (turkey and frog erythrocyte) beta-adrenergic receptors was similar, displaying EC 50 values of 400-900 pM for inhibiting 125 I-cyanopindolol binding to these receptors. pBABC reduced the number of beta-adrenergic receptors in frog erythrocyte membranes, without any change in the affinity of the remaining sites for [ 125 I]iodocyanopindolol. pBABC has been radioiodinated. As assessed by sodium dodecyl sulfate-polyacrylamide gel electrophoresis, this affinity probe specifically labeled the beta-adrenergic peptide of a purified preparation of hamster lung, with high efficiency (approximately 40%) and with a pharmacological specificity characteristic of an interaction at the beta 2-adrenergic receptor ligand-binding site. Comparison of the proteolyzed products derived from purified receptor labeled with [ 125 I]pBABC and with the photoaffinity agent [ 125 I]p-azidobenzylcarazolol suggested that covalent labeling of the beta-adrenergic receptor by these probes occurs at similar domains of the beta-adrenergic receptor

  9. BETA SPECTRA. I. Negatrons spectra

    International Nuclear Information System (INIS)

    Grau Malonda, A.; Garcia-Torano, E.

    1978-01-01

    Using the Fermi theory of beta decay, the beta spectra for 62 negatrons emitters have been computed introducing a correction factor for unique forbidden transitions. These spectra are plotted vs. energy, once normal i sed, and tabulated with the related Fermi functions. The average and median energies are calculated. (Author)

  10. Integrin {alpha}{beta}1, {alpha}{sub v}{beta}, {alpha}{sub 6}{beta} effectors p130Cas, Src and talin regulate carcinoma invasion and chemoresistance

    Energy Technology Data Exchange (ETDEWEB)

    Sansing, Hope A. [Department of Oral and Craniofacial Biology, Louisiana State University Health Sciences Center-New Orleans, School of Dentistry, New Orleans, LA (United States); Sarkeshik, Ali; Yates, John R. [Department of Chemical Physiology, Scripps Research Institute, La Jolla, CA (United States); Patel, Vyomesh; Gutkind, J. Silvio [Oral and Pharyngeal Cancer Branch, National Institute of Dental and Craniofacial Research, National Institutes of Health, Bethesda, MD (United States); Yamada, Kenneth M. [Laboratory of Cell and Developmental Biology, National Institute of Dental and Craniofacial Research, National Institutes of Health, Bethesda, MD (United States); Berrier, Allison L., E-mail: allison.berrier@gmail.com [Department of Oral and Craniofacial Biology, Louisiana State University Health Sciences Center-New Orleans, School of Dentistry, New Orleans, LA (United States)

    2011-03-11

    Research highlights: {yields} Proteomics of clustered integrin {alpha}{beta}1, {alpha}{sub v}{beta}, {alpha}{sub 6}{beta} receptors in oral carcinoma. {yields} p130Cas, Dek, Src and talin regulate oral carcinoma invasion. {yields} p130Cas, talin, Src and zyxin regulate oral carcinoma resistance to cisplatin. -- Abstract: Ligand engagement by integrins induces receptor clustering and formation of complexes at the integrin cytoplasmic face that controls cell signaling and cytoskeletal dynamics critical for adhesion-dependent processes. This study searches for a subset of integrin effectors that coordinates both tumor cell invasion and resistance to the chemotherapeutic drug cisplatin in oral carcinomas. Candidate integrin effectors were identified in a proteomics screen of proteins recruited to clustered integrin {alpha}{beta}1, {alpha}{sub v}{beta} or {alpha}{sub 6}{beta} receptors in oral carcinomas. Proteins with diverse functions including microtubule and actin binding proteins, and factors involved in trafficking, transcription and translation were identified in oral carcinoma integrin complexes. Knockdown of effectors in the oral carcinoma HN12 cells revealed that p130Cas, Dek, Src and talin were required for invasion through Matrigel. Disruption of talin or p130Cas by RNA interference increased resistance to cisplatin, whereas targeting Dek, Src or zyxin reduced HN12 resistance to cisplatin. Analysis of the spreading of HN12 cells on collagen I and laminin I revealed that a decrease in p130Cas or talin expression inhibited spreading on both matrices. Interestingly, a reduction in zyxin expression enhanced spreading on laminin I and inhibited spreading on collagen I. Reduction of Dek, Src, talin or zyxin expression reduced HN12 proliferation by 30%. Proliferation was not affected by a reduction in p130Cas expression. We conclude that p130Cas, Src and talin function in both oral carcinoma invasion and resistance to cisplatin.

  11. How Should Beta-Diversity Inform Biodiversity Conservation?

    Science.gov (United States)

    Socolar, Jacob B; Gilroy, James J; Kunin, William E; Edwards, David P

    2016-01-01

    To design robust protected area networks, accurately measure species losses, or understand the processes that maintain species diversity, conservation science must consider the organization of biodiversity in space. Central is beta-diversity--the component of regional diversity that accumulates from compositional differences between local species assemblages. We review how beta-diversity is impacted by human activities, including farming, selective logging, urbanization, species invasions, overhunting, and climate change. Beta-diversity increases, decreases, or remains unchanged by these impacts, depending on the balance of processes that cause species composition to become more different (biotic heterogenization) or more similar (biotic homogenization) between sites. While maintaining high beta-diversity is not always a desirable conservation outcome, understanding beta-diversity is essential for protecting regional diversity and can directly assist conservation planning. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Augmented Beta rectangular regression models: A Bayesian perspective.

    Science.gov (United States)

    Wang, Jue; Luo, Sheng

    2016-01-01

    Mixed effects Beta regression models based on Beta distributions have been widely used to analyze longitudinal percentage or proportional data ranging between zero and one. However, Beta distributions are not flexible to extreme outliers or excessive events around tail areas, and they do not account for the presence of the boundary values zeros and ones because these values are not in the support of the Beta distributions. To address these issues, we propose a mixed effects model using Beta rectangular distribution and augment it with the probabilities of zero and one. We conduct extensive simulation studies to assess the performance of mixed effects models based on both the Beta and Beta rectangular distributions under various scenarios. The simulation studies suggest that the regression models based on Beta rectangular distributions improve the accuracy of parameter estimates in the presence of outliers and heavy tails. The proposed models are applied to the motivating Neuroprotection Exploratory Trials in Parkinson's Disease (PD) Long-term Study-1 (LS-1 study, n = 1741), developed by The National Institute of Neurological Disorders and Stroke Exploratory Trials in Parkinson's Disease (NINDS NET-PD) network. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Absolute measurement of {beta} emitters with a 4 {pi} counter; Mesure absolue des emetteurs {beta} au compteur 4 {pi}

    Energy Technology Data Exchange (ETDEWEB)

    Le Gallic, Y [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1959-06-15

    The object of this work is to investigate the conditions under which the activity of {beta}-emitting radionuclides may be measured with a maximum of precision, and as a result to study the relevant corrections. The various problems relating to activity measurements with a 4 {pi} counter have been examined successively: - comparison of 4 {pi}, GM and proportional counters; - study of the preparation of sources; - corrections on the counting of sources; - self-absorption; - correction for absorption. The precision obtained on these measurements varies from 1.2 to 3 per cent, with the result that the 4 {pi} counter can be considered a very satisfactory calibration instrument. (author) [French] Le but de ce travail est de rechercher les conditions permettant d'obtenir avec le maximum de precision, la mesure de l'activite des radionuclides se desintegrant par emission et par consequent d'etudier les corrections qui s'y rapportent. Nous avons examine successivement les differents problemes se rapportant aux mesures d'activite au compteur 4 {pi}: - Comparaison des compteurs 4 {pi}, GM et proportionnel; - etude de la preparation des sources; - corrections sur la numeration des sources; - auto-absorption; - correction d'absorption. La precision obtenue dans ces mesures, variant de 1,2 a 3 pour cent, on peut donc considerer le compteur 4 {pi} comme un instrument d'etalonnage tres satisfaisant. (auteur)

  14. Absolute measurement of {beta} emitters with a 4 {pi} counter; Mesure absolue des emetteurs {beta} au compteur 4 {pi}

    Energy Technology Data Exchange (ETDEWEB)

    Le Gallic, Y. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1959-06-15

    The object of this work is to investigate the conditions under which the activity of {beta}-emitting radionuclides may be measured with a maximum of precision, and as a result to study the relevant corrections. The various problems relating to activity measurements with a 4 {pi} counter have been examined successively: - comparison of 4 {pi}, GM and proportional counters; - study of the preparation of sources; - corrections on the counting of sources; - self-absorption; - correction for absorption. The precision obtained on these measurements varies from 1.2 to 3 per cent, with the result that the 4 {pi} counter can be considered a very satisfactory calibration instrument. (author) [French] Le but de ce travail est de rechercher les conditions permettant d'obtenir avec le maximum de precision, la mesure de l'activite des radionuclides se desintegrant par emission et par consequent d'etudier les corrections qui s'y rapportent. Nous avons examine successivement les differents problemes se rapportant aux mesures d'activite au compteur 4 {pi}: - Comparaison des compteurs 4 {pi}, GM et proportionnel; - etude de la preparation des sources; - corrections sur la numeration des sources; - auto-absorption; - correction d'absorption. La precision obtenue dans ces mesures, variant de 1,2 a 3 pour cent, on peut donc considerer le compteur 4 {pi} comme un instrument d'etalonnage tres satisfaisant. (auteur)

  15. Other characterizations of $\\beta$-$\\theta$-R0 topological spaces

    OpenAIRE

    Miguel Caldas Cueva

    2013-01-01

    In this paper we give other characterizations of $\\beta$-$\\theta$-$%R_0$ and also introduce a new separation axiom called$\\beta$-$\\theta$-$R_1$. It turns out that $\\beta$-$\\theta$-$R_1$ isstronger that $\\beta$-$\\theta$-$R_0$

  16. The LPCTrap experiment: measurement of the {beta}-{nu} angular correlation in {sup 6}He{sup +} decay using a transparent Paul trap

    Energy Technology Data Exchange (ETDEWEB)

    Velten, Ph., E-mail: velten@lpccaen.in2p3.fr; Ban, G.; Durand, D.; Flechard, X.; Lienard, E.; Mauger, F.; Mery, A.; Naviliat-Cuncic, O.; Rodriguez, D.; Thomas, J. C. [Universite de Caen, LPC Caen, ENSICAEN (France)

    2011-07-15

    The LPCTrap experiment is devoted to the precise measurement of the {beta}-{nu} angular correlation parameter, a{sub {beta}{nu}}, in the pure Gamow-Teller decay of {sup 6}He{sup +}. This experiment is motivated by the search of the presence of tensor type contributions in the weak interaction. The radioactive source is confined in a transparent Paul trap installed at LIRAT, the low energy beam line of the SPIRAL facility. The {beta}-{nu} correlation is studied by measuring the time of flight of the recoil ions detected in coincidence with the {beta} particles. During the last experiment, a total of 4 Multiplication-Sign 10{sup 6} coincidence events have been recorded which would enable to determine the coefficient with a statistical uncertainty of 0.5%. The status of the analysis is presented in this contribution.

  17. Field transportable beta spectrometer. Innovative technology summary report

    International Nuclear Information System (INIS)

    1998-12-01

    The objective of the Large-Scale Demonstration Project (LSDP) is to select and demonstrate potentially beneficial technologies at the Argonne National Laboratory-East (ANL) Chicago Pile-5 Test Reactor (CP-5). The purpose of the LSDP is to demonstrate that by using innovative and improved deactivation and decommissioning (D and D) technologies from various sources, significant benefits can be achieved when compared to baseline D and D technologies. One such capability being addressed by the D and D Focus Area is rapid characterization for facility contaminants. The technology was field demonstrated during the period January 7 through January 9, 1997, and offers several potential benefits, including faster turn-around time, cost reduction, and reduction in secondary waste. This report describes a PC controlled, field-transportable beta counter-spectrometer which uses solid scintillation coincident counting and low-noise photomultiplier tubes to count element-selective filters and other solid media. The dry scintillation counter used in combination with an element-selective technology eliminates the mess and disposal costs of liquid scintillation cocktails. Software in the instrument provides real-time spectral analysis. The instrument can detect and measure Tc-99, Sr-90, and other beta emitters reaching detection limits in the 20 pCi range (with shielding). Full analysis can be achieved in 30 minutes. The potential advantages of a field-portable beta counter-spectrometer include the savings gained from field generated results. The basis for decision-making is provided with a rapid turnaround analysis in the field. This technology would be competitive with the radiometric analysis done in fixed laboratories and the associated chain of custody operations

  18. Beta-agonists and animal welfare

    Science.gov (United States)

    The use of beta-agonists in animal feed is a high profile topic within the U.S. as consumers and activist groups continue to question its safety. The only beta-agonist currently available for use in swine is ractopamine hydrochloride (RAC). This is available as Paylean™ (Elanco Animal Health – FDA a...

  19. Review of the beta situation

    International Nuclear Information System (INIS)

    Sheffield, J.

    1982-01-01

    This note lists some of the possible causes of beta limitation in tokamak and discusses what is known and what is involved in investigating them. The motivation for preparing this note is the observed degradation of confinement with increasing beta poloidal β/sub p/ and beam power P/sub b/ in ISX-B

  20. Differential Recognition of CD1d-[alpha]-Galactosyl Ceramide by the V[beta]8.2 and V[beta]7 Semi-invariant NKT T Cell Receptors

    Energy Technology Data Exchange (ETDEWEB)

    Pellicci, Daniel G.; Patel, Onisha; Kjer-Nielsen, Lars; Pang, Siew Siew; Sullivan, Lucy C.; Kyparissoudis, Konstantinos; Brooks, Andrew G.; Reid, Hugh H.; Gras, Stephanie; Lucet, Isabelle S.; Koh, Ruide; Smyth, Mark J.; Mallevaey, Thierry; Matsuda, Jennifer L.; Gapin, Laurent; McCluskey, James; Godfrey, Dale I.; Rossjohn, Jamie; PMCI-A; Monash; UCHSC; Melbourne

    2009-09-02

    The semi-invariant natural killer T cell receptor (NKT TCR) recognizes CD1d-lipid antigens. Although the TCR{alpha} chain is typically invariant, the {beta} chain expression is more diverse, where three V{beta} chains are commonly expressed in mice. We report the structures of V{alpha}14-V{beta}8.2 and V{alpha}14-V{beta}7 NKT TCRs in complex with CD1d-{alpha}-galactosylceramide ({alpha}-GalCer) and the 2.5 {angstrom} structure of the human NKT TCR-CD1d-{alpha}-GalCer complex. Both V{beta}8.2 and V{beta}7 NKT TCRs and the human NKT TCR ligated CD1d-{alpha}-GalCer in a similar manner, highlighting the evolutionarily conserved interaction. However, differences within the V{beta} domains of the V{beta}8.2 and V{beta}7 NKT TCR-CD1d complexes resulted in altered TCR{beta}-CD1d-mediated contacts and modulated recognition mediated by the invariant {alpha} chain. Mutagenesis studies revealed the differing contributions of V{beta}8.2 and V{beta}7 residues within the CDR2{beta} loop in mediating contacts with CD1d. Collectively we provide a structural basis for the differential NKT TCR V{beta} usage in NKT cells.

  1. Structure of the T cell receptor in a Ti alpha V beta 2, alpha V beta 8-positive T cell line

    DEFF Research Database (Denmark)

    Hou, X; Dietrich, J; Kuhlmann, J

    1994-01-01

    not known; however, it has been suggested that each TcR contains two Ti dimers. To gain insight into the structure of the TcR we constructed a Ti alpha V beta 2, alpha V beta 8-positive T cell line which expressed the endogenous human TiV beta 8 and the transfected mouse TiV beta 2 both in association......The T cell receptor (TcR) is composed of at least six different polypeptide chains consisting of the clonotypic Ti heterodimer (Ti alpha beta or Ti gamma delta) and the noncovalently associated CD3 chains (CD3 gamma delta epsilon zeta). The exact number of subunits constituting the TcR is still...... with the endogenous Ti alpha and CD3 chains at the cell surface. Preclearing experiments with radioiodinated cell lysate prepared with digitonin lysis buffer demonstrated that depleting the lysate of Ti alpha V beta 8 by immunoprecipitation with anti V beta 8 monoclonal antibody (mAb) did not reduce the amount of Ti...

  2. Desensitization in patients with beta-lactam drug allergy.

    Science.gov (United States)

    Yusin, J S; Klaustermeyer, W; Simmons, C W; Baum, M

    2013-01-01

    Patients with a history of beta-lactam antibiotic allergy are often admitted to the hospital with severe or life-threatening infections requiring beta-lactam antibiotics. Strict avoidance of beta lactams to such patients may prevent them from getting adequate coverage and can lead to an increase in the use of alternative antibiotics, which can predispose to antibiotic resistance. Past studies revealed a lower incidence of pen allergy then patients' histories suggest. Fortunately today, there are three options for patients presenting with a history of beta-lactam allergy. Penicillin skin testing, beta-lactam challenge or beta-lactam desensitization. Recently Pre Pen has been FDA re-approved and when combined with Pen G is a valid way to determine if patients are able to tolerate beta-lactam antibiotic. When these agents are not available one must decide about desensitization or challenge. When a patient has a positive penicillin skin test, desensitization or beta-lactam avoidance are the only options. This paper reviews the safety of beta-lactam desensitization. To perform a chart review on patients desensitised with beta lactam to determine if desensitizations can be performed safely without minimal complications. A retrospective chart review was performed on allergy and immunology inpatient consultations for beta-lactam desensitization between September 2003 and August 2006 at the Cedars-Sinai Medical Centre in Los Angeles. Patient data and outcomes of desensitization were analysed. A total of 13 intravenous desensitizations were performed on 12 patients. The patients consisted of eight females and four males with an average age of 65 years. Age range was 36-92 years old. All 13 intravenous desensitizations were completed without complications. No patient required a slower rate of desensitization or discontinuance of the desensitization. Patients were able to tolerate the initial therapeutic dose of their beta-lactam antibiotic and were then able to complete full

  3. Evaluation of the RSG-GAS Alpha-Beta Aerosol Contaminant Monitor Performance Under Reactor Operation Condition

    International Nuclear Information System (INIS)

    Hartoyo, Unggul; Setiawanto, Anto; Sumarno, Yulius

    2000-01-01

    Analysis to evaluate the RSG-GAS alpha-beta aerosol contaminant monitor performance was done. The high potential radiation working area such as in RSG-GAS is important to monitored for personal safety. Further it is necessary to assure that the system monitor is reliable enough under normal conditions as well as emergency condition. The method uses in this analysis are monitoring and comparing with the standard source. The standard course indicator and panel in main control room indicate that the result is 1 x 110 exp 9 Ci/m exp 3. Based on data monitor observation, the RSG-GAS alpha-beta aerosol contaminant monitor system under reactor operation condition has a good enough performance

  4. Theoretical aspects of double beta decay

    International Nuclear Information System (INIS)

    Haxton, W.C.

    1984-01-01

    Considerable effort has been expended recently in theoretical studies of double beta decay. Much of this work has focussed on the constraints this process places on gauge theories of the weak interaction, in general, and on the neutrino mass matrix, in particular. In addition, interesting nuclear structure questions have arisen in studies of double beta decay matrix elements. After briefly reviewing the theory of double beta decay, some of the progress that has been made in these areas is summarized. 25 references

  5. Cytokines interleukin-1beta and tumor necrosis factor-alpha regulate different transcriptional and alternative splicing networks in primary beta-cells

    DEFF Research Database (Denmark)

    Ortis, Fernanda; Naamane, Najib; Flamez, Daisy

    2010-01-01

    by the cytokines interleukin (IL)-1beta + interferon (IFN)-gamma and tumor necrosis factor (TNF)-alpha + IFN-gamma in primary rat beta-cells. RESEARCH DESIGN AND METHODS: Fluorescence-activated cell sorter-purified rat beta-cells were exposed to IL-1beta + IFN-gamma or TNF-alpha + IFN-gamma for 6 or 24 h......-cells, with temporal differences in the number of genes modulated by IL-1beta + IFNgamma or TNF-alpha + IFN-gamma. These cytokine combinations induced differential expression of inflammatory response genes, which is related to differential induction of IFN regulatory factor-7. Both treatments decreased the expression...... of genes involved in the maintenance of beta-cell phenotype and growth/regeneration. Cytokines induced hypoxia-inducible factor-alpha, which in this context has a proapoptotic role. Cytokines also modified the expression of >20 genes involved in RNA splicing, and exon array analysis showed cytokine...

  6. Beta-binomial regression and bimodal utilization.

    Science.gov (United States)

    Liu, Chuan-Fen; Burgess, James F; Manning, Willard G; Maciejewski, Matthew L

    2013-10-01

    To illustrate how the analysis of bimodal U-shaped distributed utilization can be modeled with beta-binomial regression, which is rarely used in health services research. Veterans Affairs (VA) administrative data and Medicare claims in 2001-2004 for 11,123 Medicare-eligible VA primary care users in 2000. We compared means and distributions of VA reliance (the proportion of all VA/Medicare primary care visits occurring in VA) predicted from beta-binomial, binomial, and ordinary least-squares (OLS) models. Beta-binomial model fits the bimodal distribution of VA reliance better than binomial and OLS models due to the nondependence on normality and the greater flexibility in shape parameters. Increased awareness of beta-binomial regression may help analysts apply appropriate methods to outcomes with bimodal or U-shaped distributions. © Health Research and Educational Trust.

  7. Fabrication of beta particles detector for RMS

    International Nuclear Information System (INIS)

    Lee, W. G.; Kim, Y. G.; Kim, J. B.; Jeong, J. E.; Hong, S. B.

    2003-01-01

    The beta particles detector for RMS (radiation monitoring system) was fabricated to detect charged beta particles. The plastic scintillator was cutted, shaped, polished to make plastic disk for beta particles. The diameter of completed plastic scintillator disk is 40 mm and thickness is 1.5 mm. The mylar film and aluminium foil were used the front of plastic scintillator to intercept light and moisture. The completed plastic detector for RMS consist of the discriminator and counter were made by ULS (Co.). The absolute efficiency of plastic detector was 45.51% for beta particles (Sr/Y - 90)

  8. Localization of thymosin beta-4 in tumors

    DEFF Research Database (Denmark)

    Larsson, L. -I.; Holck, Susanne

    2007-01-01

    in colorectal carcinomas. The degree of staining of breast cancer cells for thymosin beta-4 correlated neither to histological grade nor to endothelial cell staining. However, there was a tendency toward correlation (P = 0.07) between staining of endothelial cells and histological grade. Treatment of cultured......Overexpression of thymosin beta-4 has been linked to malignant progression but the localization of this polypeptide within tumors is incompletely known. We therefore examined breast cancers for thymosin beta-4 using immunofluorescence. Reactive cells were identified with monoclonal cell marker...... breast cancer cells (SK-BR-3) with 1-4 microg thymosin beta-4/mL significantly increased cell numbers, as determined by MTT-assays. These data reveal an unexpected cellular heterogeneity of thymosin beta-4 expression in breast and colonic carcinomas and suggest that local release of this polypeptide...

  9. PDX1, Neurogenin-3, and MAFA: critical transcription regulators for beta cell development and regeneration

    Directory of Open Access Journals (Sweden)

    Yaxi Zhu

    2017-11-01

    Full Text Available Abstract Transcription factors regulate gene expression through binding to specific enhancer sequences. Pancreas/duodenum homeobox protein 1 (PDX1, Neurogenin-3 (NEUROG3, and V-maf musculoaponeurotic fibrosarcoma oncogene homolog A (MAFA are transcription factors critical for beta cell development and maturation. NEUROG3 is expressed in endocrine progenitor cells and controls islet differentiation and regeneration. PDX1 is essential for the development of pancreatic exocrine and endocrine cells including beta cells. PDX1 also binds to the regulatory elements and increases insulin gene transcription. Likewise, MAFA binds to the enhancer/promoter region of the insulin gene and drives insulin expression in response to glucose. In addition to those natural roles in beta cell development and maturation, ectopic expression of PDX1, NEUROG3, and/or MAFA has been successfully used to reprogram various cell types into insulin-producing cells in vitro and in vivo, such as pancreatic exocrine cells, hepatocytes, and pluripotent stem cells. Here, we review biological properties of PDX1, NEUROG3, and MAFA, and their applications and limitations for beta cell regenerative approaches. The primary source literature for this review was acquired using a PubMed search for articles published between 1990 and 2017. Search terms include diabetes, insulin, trans-differentiation, stem cells, and regenerative medicine.

  10. Energy calibration of a silicon detector using pure beta-emitters

    International Nuclear Information System (INIS)

    Borras, C.; Los Arcos, J.M.

    1992-01-01

    Energy calibration of Si detectors used in electron spectroscopy is commonly performed with conversion electron sources or monoenergetic electrons beams, which are preferred against beta emitters due to the problems arising from their continuous spectra. This paper presents a simple calibration procedure for a PIP-type silicon detector, using 1 4C, 1 47m, 9 9Tc and 4 5Ca, that is based on the correspondence between the average channel observed in the experimental spectrum and the mean energy evaluated from the theoretical Fermi distribution for each nuclide. First, a method for evaluating the average channel in the experimental spectrum distorted by the electronic noise is described and its uncertainty estimated. Then, the channel-energy relation ship is established by least squares fitting modified to account for uncertainties in both variables. The calibration has been successfully verified with 147Pm and 109Cs source, showing discrepancies not greater than 2.5%, within the uncertainties due to the detector resolution and the sources features. (author)

  11. A scandium calibration source for the SNO+ experiment

    Energy Technology Data Exchange (ETDEWEB)

    Boeltzig, Axel; Barros, Nuno; Krueger, Felix; Krosigk, Belina von; Lozza, Valentina; Neumann, Laura; Petzoldt, Johannes; Soerensen, Arnd; Zuber, Kai [TU Dresden (Germany)

    2013-07-01

    The SNO+ experiment is the successor of SNO (Sudbury Neutrino Observatory), for which the detector will be filled with liquid scintillator. Located 2 km underground (equivalent to a shielding of about 6 km of water) in a mine near Sudbury, Canada, SNO+ will be a low-background experiment studying different aspects of neutrinos. The SNO+ detector calibration is scheduled to begin in mid-2013 with a water-filled detector and in 2014 filled with liquid scintillator. One of the sources designated for this calibration will use the γ rays following the beta decay of {sup 48}Sc. The sum of their energies is 3.333 MeV for the main decay branch, which is close to Q=3.371 MeV for the neutrino-less double beta decay of {sup 150}Nd that SNO+ plans to investigate. Due to the {sup 48}Sc half-life of 43.67 h, the source has to be produced shortly before the calibration via (n,p) reactions on {sup 48}Ti. Safety, radiopurity and cleanliness are further important issues for its application. The current status of the source development will be presented.

  12. Peginterferon beta-1a – nowa postać interferonu beta-1a

    Directory of Open Access Journals (Sweden)

    Zdzisław Maciejek

    2015-11-01

    Full Text Available W 2014 roku, po zakończeniu próby klinicznej III fazy ADVANCE, do leczenia postaci rzutowo-remisyjnej stwardnienia rozsianego wprowadzono nową pegylowaną postać interferonu beta-1a o wydłużonym czasie działania. Do badania zakwalifikowano 1512 chorych ze 183 ośrodków z 26 krajów (500 uczestników przyjmowało placebo, 512 – peginterferon beta-1a w dawce 125 µg podawany podskórnie co 2 tygodnie, 500 – peginterferon beta-1a w dawce 125 µg podawany podskórnie co 4 tygodnie. Grupy były zbliżone pod względem wieku, płci, czasu trwania choroby i niepełnosprawności ocenianej w Expanded Disability Status Scale. Cel badania stanowiła ocena skuteczności i bezpieczeństwa pegylowanego interferonu beta-1a po 2 latach terapii w porównaniu z grupą placebo, która w drugim roku również otrzymywała ten lek. Skuteczność peginterferonu beta-1a podawanego co 2 tygodnie w porównaniu z placebo przejawiała się redukcją rocznego wskaźnika rzutów (o 37%, liczby nowych lub powiększonych ognisk T2-zależnych (o 67%, ryzyka wystąpienia rzutu (o 39% i ryzyka utrwalonej 12-tygodniowej progresji niepełnosprawności (o 33%. Najczęstsze działania niepożądane towarzyszące kuracji (94% chorych to odczyn w miejscu wkłucia, objawy grypopodobne, gorączka i bóle głowy. U 16% osób przyjmujących lek co 2 tygodnie i 22% otrzymujących go co 4 tygodnie odnotowano poważne objawy niepożądane (rzuty, zapalenie płuc, infekcje dróg moczowych. Reasumując: leczenie peginterferonem beta-1a cechowały skuteczność, dobra tolerancja i bezpieczeństwo.

  13. Beta decay of Cu-56

    NARCIS (Netherlands)

    Borcea, R; Aysto, J; Caurier, E; Dendooven, P; Doring, J; Gierlik, M; Gorska, M; Grawe, H; Hellstrom, M; Janas, Z; Jokinen, A; Karny, M; Kirchner, R; La Commara, M; Langanke, K; Martinez-Pinedo, G; Mayet, P; Nieminen, A; Nowacki, F; Penttila, H; Plochocki, A; Rejmund, M; Roeckl, E; Schlegel, C; Schmidt, K; Schwengner, R; Sawicka, M

    2001-01-01

    The proton-rich isotope Cu-56 was produced at the GSI On-Line Mass Separator by means of the Si-28(S-32, p3n) fusion-evaporation reaction. Its beta -decay properties were studied by detecting beta -delayed gamma rays and protons. A half-Life of 93 +/- 3 ms was determined for Cu-56. Compared to the

  14. Coexistence of Extended Spectrum Beta-Lactamases, AmpC Beta-Lactamases and Metallo-Beta-Lactamases in Acinetobacter baumannii from burns patients: a report from a tertiary care centre of India

    OpenAIRE

    Gupta, V.; Garg, R.; Garg, S.; Chander, J.; Attri, A.K.

    2013-01-01

    Multidrug-resistant Acinetobacter baumanii is a major pathogen encountered in pyogenic infections, especially from burns patients in hospital settings. Often there is also coexistence of multiple beta-lactamase enzymes responsible for beta-lactam resistance in a single isolate, which further complicates treatment options. We conducted a study on burn wound pus samples obtained from the burns unit of our hospital. Phenotypic tests were used to determine the Extended Spectrum Beta-Lactamase, Am...

  15. Systematic risk variations (beta convertible debenture brazilian companies

    Directory of Open Access Journals (Sweden)

    Renata Drumond Pinto Coelho Antonino

    2010-01-01

    Full Text Available purpose of this article is to analyze the impact of issuing convertible debentures on the systematic risk of Brazilian companies. Some applied researches in the U.S. capital market (STEIN, 1992; LEWIS et al, 2002; RAI, 2005 indicate that convertible debentures may be used as an alternative financing source when adverse selection problem makes stock issuing unattractive financing source. The analysis of Brazilian companies that issued convertible debentures recorded in the period from 1998 to 2006 and that presented liquidity on the market indicated that variation in beta, on average, is positive. These results are coherent with the signaling hypothesis and with the absence of convertible debenture issuing in 2005 and 2006 on the Brazilian market. They also may be related to the precarious financial situation of issuing companies, observed by the analysis of some financial indicators in year of issue and in two pre- e post-issuing years.

  16. Cholesterol enhances amyloid {beta} deposition in mouse retina by modulating the activities of A{beta}-regulating enzymes in retinal pigment epithelial cells

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jiying [Department of Ophthalmology and Visual Science, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8519 (Japan); Ohno-Matsui, Kyoko, E-mail: k.ohno.oph@tmd.ac.jp [Department of Ophthalmology and Visual Science, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8519 (Japan); Morita, Ikuo [Section of Cellular Physiological Chemistry, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8519 (Japan)

    2012-08-10

    Highlights: Black-Right-Pointing-Pointer Cholesterol-treated RPE produces more A{beta} than non-treated RPE. Black-Right-Pointing-Pointer Neprilysin expression and activity decreased in cholesterol-treated RPE. Black-Right-Pointing-Pointer {alpha}-Secretase expression and activity decreased in cholesterol-treated RPE. Black-Right-Pointing-Pointer Cholesterol-enriched diet induced subRPE deposits in aged mice. Black-Right-Pointing-Pointer A{beta} were present in cholesterol-enriched-diet-induced subRPE deposits in aged mice. -- Abstract: Subretinally-deposited amyloid {beta} (A{beta}) is a main contributor of developing age-related macular degeneration (AMD). However, the mechanism causing A{beta} deposition in AMD eyes is unknown. Hypercholesterolemia is a significant risk for developing AMD. Thus, we investigated the effects of cholesterol on A{beta} production in retinal pigment epithelial (RPE) cells in vitro and in the mouse retina in vivo. RPE cells isolated from senescent (12-month-old) C57BL/6 mice were treated with 10 {mu}g/ml cholesterol for 48 h. A{beta} amounts in culture supernatants were measured by ELISA. Activity and expression of enzymes and proteins that regulate A{beta} production were examined by activity assay and real time PCR. The retina of mice fed cholesterol-enriched diet was examined by transmission electron microscopy. Cholesterol significantly increased A{beta} production in cultured RPE cells. Activities of A{beta} degradation enzyme; neprilysin (NEP) and anti-amyloidogenic secretase; {alpha}-secretase were significantly decreased in cell lysates of cholesterol-treated RPE cells compared to non-treated cells, but there was no change in the activities of {beta}- or {gamma}-secretase. mRNA levels of NEP and {alpha}-secretase (ADAM10 and ADAM17) were significantly lower in cholesterol-treated RPE cells than non-treated cells. Senescent (12-month-old) mice fed cholesterol-enriched chow developed subRPE deposits containing A{beta}, whereas

  17. Determination of $\\gamma$ and $-2\\beta_s$ from charmless two-body decays of beauty mesons

    CERN Document Server

    Aaij, Roel; Adeva, Bernardo; Adinolfi, Marco; Affolder, Anthony; Ajaltouni, Ziad; Akar, Simon; Albrecht, Johannes; Alessio, Federico; Alexander, Michael; Ali, Suvayu; Alkhazov, Georgy; Alvarez Cartelle, Paula; Alves Jr, Antonio Augusto; Amato, Sandra; Amerio, Silvia; Amhis, Yasmine; An, Liupan; Anderlini, Lucio; Anderson, Jonathan; Andreassen, Rolf; Andreotti, Mirco; Andrews, Jason; Appleby, Robert; Aquines Gutierrez, Osvaldo; Archilli, Flavio; Artamonov, Alexander; Artuso, Marina; Aslanides, Elie; Auriemma, Giulio; Baalouch, Marouen; Bachmann, Sebastian; Back, John; Badalov, Alexey; Baesso, Clarissa; Baldini, Wander; Barlow, Roger; Barschel, Colin; Barsuk, Sergey; Barter, William; Batozskaya, Varvara; Battista, Vincenzo; Bay, Aurelio; Beaucourt, Leo; Beddow, John; Bedeschi, Franco; Bediaga, Ignacio; Belogurov, Sergey; Belous, Konstantin; Belyaev, Ivan; Ben-Haim, Eli; Bencivenni, Giovanni; Benson, Sean; Benton, Jack; Berezhnoy, Alexander; Bernet, Roland; Bettler, Marc-Olivier; van Beuzekom, Martinus; Bien, Alexander; Bifani, Simone; Bird, Thomas; Bizzeti, Andrea; Bjørnstad, Pål Marius; Blake, Thomas; Blanc, Frédéric; Blouw, Johan; Blusk, Steven; Bocci, Valerio; Bondar, Alexander; Bondar, Nikolay; Bonivento, Walter; Borghi, Silvia; Borgia, Alessandra; Borsato, Martino; Bowcock, Themistocles; Bowen, Espen Eie; Bozzi, Concezio; Brambach, Tobias; Bressieux, Joël; Brett, David; Britsch, Markward; Britton, Thomas; Brodzicka, Jolanta; Brook, Nicholas; Brown, Henry; Bursche, Albert; Busetto, Giovanni; Buytaert, Jan; Cadeddu, Sandro; Calabrese, Roberto; Calvi, Marta; Calvo Gomez, Miriam; Campana, Pierluigi; Campora Perez, Daniel; Carbone, Angelo; Carboni, Giovanni; Cardinale, Roberta; Cardini, Alessandro; Carson, Laurence; Carvalho Akiba, Kazuyoshi; Casse, Gianluigi; Cassina, Lorenzo; Castillo Garcia, Lucia; Cattaneo, Marco; Cauet, Christophe; Cenci, Riccardo; Charles, Matthew; Charpentier, Philippe; Chefdeville, Maximilien; Chen, Shanzhen; Cheung, Shu-Faye; Chiapolini, Nicola; Chrzaszcz, Marcin; Ciba, Krzystof; Cid Vidal, Xabier; Ciezarek, Gregory; Clarke, Peter; Clemencic, Marco; Cliff, Harry; Closier, Joel; Coco, Victor; Cogan, Julien; Cogneras, Eric; Cojocariu, Lucian; Collins, Paula; Comerma-Montells, Albert; Contu, Andrea; Cook, Andrew; Coombes, Matthew; Coquereau, Samuel; Corti, Gloria; Corvo, Marco; Counts, Ian; Couturier, Benjamin; Cowan, Greig; Craik, Daniel Charles; Cruz Torres, Melissa Maria; Cunliffe, Samuel; Currie, Robert; D'Ambrosio, Carmelo; Dalseno, Jeremy; David, Pascal; David, Pieter; Davis, Adam; De Bruyn, Kristof; De Capua, Stefano; De Cian, Michel; De Miranda, Jussara; De Paula, Leandro; De Silva, Weeraddana; De Simone, Patrizia; Decamp, Daniel; Deckenhoff, Mirko; Del Buono, Luigi; Déléage, Nicolas; Derkach, Denis; Deschamps, Olivier; Dettori, Francesco; Di Canto, Angelo; Dijkstra, Hans; Donleavy, Stephanie; Dordei, Francesca; Dorigo, Mirco; Dosil Suárez, Alvaro; Dossett, David; Dovbnya, Anatoliy; Dreimanis, Karlis; Dujany, Giulio; Dupertuis, Frederic; Durante, Paolo; Dzhelyadin, Rustem; Dziurda, Agnieszka; Dzyuba, Alexey; Easo, Sajan; Egorychev, Victor; Eidelman, Semen; Eisenhardt, Stephan; Eitschberger, Ulrich; Ekelhof, Robert; Eklund, Lars; El Rifai, Ibrahim; Elsasser, Christian; Ely, Scott; Esen, Sevda; Evans, Hannah Mary; Evans, Timothy; Falabella, Antonio; Färber, Christian; Farinelli, Chiara; Farley, Nathanael; Farry, Stephen; Fay, Robert; Ferguson, Dianne; Fernandez Albor, Victor; Ferreira Rodrigues, Fernando; Ferro-Luzzi, Massimiliano; Filippov, Sergey; Fiore, Marco; Fiorini, Massimiliano; Firlej, Miroslaw; Fitzpatrick, Conor; Fiutowski, Tomasz; Fol, Philip; Fontana, Marianna; Fontanelli, Flavio; Forty, Roger; Francisco, Oscar; Frank, Markus; Frei, Christoph; Frosini, Maddalena; Fu, Jinlin; Furfaro, Emiliano; Gallas Torreira, Abraham; Galli, Domenico; Gallorini, Stefano; Gambetta, Silvia; Gandelman, Miriam; Gandini, Paolo; Gao, Yuanning; García Pardiñas, Julián; Garofoli, Justin; Garra Tico, Jordi; Garrido, Lluis; Gaspar, Clara; Gauld, Rhorry; Gavardi, Laura; Gavrilov, Gennadii; Geraci, Angelo; Gersabeck, Evelina; Gersabeck, Marco; Gershon, Timothy; Ghez, Philippe; Gianelle, Alessio; Gianì, Sebastiana; Gibson, Valerie; Giubega, Lavinia-Helena; Gligorov, Vladimir; Göbel, Carla; Golubkov, Dmitry; Golutvin, Andrey; Gomes, Alvaro; Gotti, Claudio; Grabalosa Gándara, Marc; Graciani Diaz, Ricardo; Granado Cardoso, Luis Alberto; Graugés, Eugeni; Graziani, Giacomo; Grecu, Alexandru; Greening, Edward; Gregson, Sam; Griffith, Peter; Grillo, Lucia; Grünberg, Oliver; Gui, Bin; Gushchin, Evgeny; Guz, Yury; Gys, Thierry; Hadjivasiliou, Christos; Haefeli, Guido; Haen, Christophe; Haines, Susan; Hall, Samuel; Hamilton, Brian; Hampson, Thomas; Han, Xiaoxue; Hansmann-Menzemer, Stephanie; Harnew, Neville; Harnew, Samuel; Harrison, Jonathan; He, Jibo; Head, Timothy; Heijne, Veerle; Hennessy, Karol; Henrard, Pierre; Henry, Louis; Hernando Morata, Jose Angel; van Herwijnen, Eric; Heß, Miriam; Hicheur, Adlène; Hill, Donal; Hoballah, Mostafa; Hombach, Christoph; Hulsbergen, Wouter; Hunt, Philip; Hussain, Nazim; Hutchcroft, David; Hynds, Daniel; Idzik, Marek; Ilten, Philip; Jacobsson, Richard; Jaeger, Andreas; Jalocha, Pawel; Jans, Eddy; Jaton, Pierre; Jawahery, Abolhassan; Jing, Fanfan; John, Malcolm; Johnson, Daniel; Jones, Christopher; Joram, Christian; Jost, Beat; Jurik, Nathan; Kaballo, Michael; Kandybei, Sergii; Kanso, Walaa; Karacson, Matthias; Karbach, Moritz; Karodia, Sarah; Kelsey, Matthew; Kenyon, Ian; Ketel, Tjeerd; Khanji, Basem; Khurewathanakul, Chitsanu; Klaver, Suzanne; Klimaszewski, Konrad; Kochebina, Olga; Kolpin, Michael; Komarov, Ilya; Koopman, Rose; Koppenburg, Patrick; Korolev, Mikhail; Kozlinskiy, Alexandr; Kravchuk, Leonid; Kreplin, Katharina; Kreps, Michal; Krocker, Georg; Krokovny, Pavel; Kruse, Florian; Kucewicz, Wojciech; Kucharczyk, Marcin; Kudryavtsev, Vasily; Kurek, Krzysztof; Kvaratskheliya, Tengiz; La Thi, Viet Nga; Lacarrere, Daniel; Lafferty, George; Lai, Adriano; Lambert, Dean; Lambert, Robert W; Lanfranchi, Gaia; Langenbruch, Christoph; Langhans, Benedikt; Latham, Thomas; Lazzeroni, Cristina; Le Gac, Renaud; van Leerdam, Jeroen; Lees, Jean-Pierre; Lefèvre, Regis; Leflat, Alexander; Lefrançois, Jacques; Leo, Sabato; Leroy, Olivier; Lesiak, Tadeusz; Leverington, Blake; Li, Yiming; Likhomanenko, Tatiana; Liles, Myfanwy; Lindner, Rolf; Linn, Christian; Lionetto, Federica; Liu, Bo; Lohn, Stefan; Longstaff, Iain; Lopes, Jose; Lopez-March, Neus; Lowdon, Peter; Lu, Haiting; Lucchesi, Donatella; Luo, Haofei; Lupato, Anna; Luppi, Eleonora; Lupton, Oliver; Machefert, Frederic; Machikhiliyan, Irina V; Maciuc, Florin; Maev, Oleg; Malde, Sneha; Malinin, Alexander; Manca, Giulia; Mancinelli, Giampiero; Mapelli, Alessandro; Maratas, Jan; Marchand, Jean François; Marconi, Umberto; Marin Benito, Carla; Marino, Pietro; Märki, Raphael; Marks, Jörg; Martellotti, Giuseppe; Martens, Aurelien; Martín Sánchez, Alexandra; Martinelli, Maurizio; Martinez Santos, Diego; Martinez Vidal, Fernando; Martins Tostes, Danielle; Massafferri, André; Matev, Rosen; Mathe, Zoltan; Matteuzzi, Clara; Mazurov, Alexander; McCann, Michael; McCarthy, James; McNab, Andrew; McNulty, Ronan; McSkelly, Ben; Meadows, Brian; Meier, Frank; Meissner, Marco; Merk, Marcel; Milanes, Diego Alejandro; Minard, Marie-Noelle; Moggi, Niccolò; Molina Rodriguez, Josue; Monteil, Stephane; Morandin, Mauro; Morawski, Piotr; Mordà, Alessandro; Morello, Michael Joseph; Moron, Jakub; Morris, Adam Benjamin; Mountain, Raymond; Muheim, Franz; Müller, Katharina; Mussini, Manuel; Muster, Bastien; Naik, Paras; Nakada, Tatsuya; Nandakumar, Raja; Nasteva, Irina; Needham, Matthew; Neri, Nicola; Neubert, Sebastian; Neufeld, Niko; Neuner, Max; Nguyen, Anh Duc; Nguyen, Thi-Dung; Nguyen-Mau, Chung; Nicol, Michelle; Niess, Valentin; Niet, Ramon; Nikitin, Nikolay; Nikodem, Thomas; Novoselov, Alexey; O'Hanlon, Daniel Patrick; Oblakowska-Mucha, Agnieszka; Obraztsov, Vladimir; Oggero, Serena; Ogilvy, Stephen; Okhrimenko, Oleksandr; Oldeman, Rudolf; Onderwater, Gerco; Orlandea, Marius; Otalora Goicochea, Juan Martin; Owen, Patrick; Oyanguren, Maria Arantza; Pal, Bilas Kanti; Palano, Antimo; Palombo, Fernando; Palutan, Matteo; Panman, Jacob; Papanestis, Antonios; Pappagallo, Marco; Pappalardo, Luciano; Parkes, Christopher; Parkinson, Christopher John; Passaleva, Giovanni; Patel, Girish; Patel, Mitesh; Patrignani, Claudia; Pazos Alvarez, Antonio; Pearce, Alex; Pellegrino, Antonio; Pepe Altarelli, Monica; Perazzini, Stefano; Perez Trigo, Eliseo; Perret, Pascal; Perrin-Terrin, Mathieu; Pescatore, Luca; Pesen, Erhan; Petridis, Konstantin; Petrolini, Alessandro; Picatoste Olloqui, Eduardo; Pietrzyk, Boleslaw; Pilař, Tomas; Pinci, Davide; Pistone, Alessandro; Playfer, Stephen; Plo Casasus, Maximo; Polci, Francesco; Poluektov, Anton; Polycarpo, Erica; Popov, Alexander; Popov, Dmitry; Popovici, Bogdan; Potterat, Cédric; Price, Eugenia; Price, Joseph David; Prisciandaro, Jessica; Pritchard, Adrian; Prouve, Claire; Pugatch, Valery; Puig Navarro, Albert; Punzi, Giovanni; Qian, Wenbin; Rachwal, Bartolomiej; Rademacker, Jonas; Rakotomiaramanana, Barinjaka; Rama, Matteo; Rangel, Murilo; Raniuk, Iurii; Rauschmayr, Nathalie; Raven, Gerhard; Redi, Federico; Reichert, Stefanie; Reid, Matthew; dos Reis, Alberto; Ricciardi, Stefania; Richards, Sophie; Rihl, Mariana; Rinnert, Kurt; Rives Molina, Vincente; Robbe, Patrick; Rodrigues, Ana Barbara; Rodrigues, Eduardo; Rodriguez Perez, Pablo; Roiser, Stefan; Romanovsky, Vladimir; Romero Vidal, Antonio; Rotondo, Marcello; Rouvinet, Julien; Ruf, Thomas; Ruiz, Hugo; Ruiz Valls, Pablo; Saborido Silva, Juan Jose; Sagidova, Naylya; Sail, Paul; Saitta, Biagio; Salustino Guimaraes, Valdir; Sanchez Mayordomo, Carlos; Sanmartin Sedes, Brais; Santacesaria, Roberta; Santamarina Rios, Cibran; Santovetti, Emanuele; Sarti, Alessio; Satriano, Celestina; Satta, Alessia; Saunders, Daniel Martin; Savrie, Mauro; Savrina, Darya; Schiller, Manuel; Schindler, Heinrich; Schlupp, Maximilian; Schmelling, Michael; Schmidt, Burkhard; Schneider, Olivier; Schopper, Andreas; Schune, Marie Helene; Schwemmer, Rainer; Sciascia, Barbara; Sciubba, Adalberto; Seco, Marcos; Semennikov, Alexander; Sepp, Indrek; Serra, Nicola; Serrano, Justine; Sestini, Lorenzo; Seyfert, Paul; Shapkin, Mikhail; Shapoval, Illya; Shcheglov, Yury; Shears, Tara; Shekhtman, Lev; Shevchenko, Vladimir; Shires, Alexander; Silva Coutinho, Rafael; Simi, Gabriele; Sirendi, Marek; Skidmore, Nicola; Skwarnicki, Tomasz; Smith, Anthony; Smith, Edmund; Smith, Eluned; Smith, Jackson; Smith, Mark; Snoek, Hella; Sokoloff, Michael; Soler, Paul; Soomro, Fatima; Souza, Daniel; Souza De Paula, Bruno; Spaan, Bernhard; Sparkes, Ailsa; Spradlin, Patrick; Sridharan, Srikanth; Stagni, Federico; Stahl, Marian; Stahl, Sascha; Steinkamp, Olaf; Stenyakin, Oleg; Stevenson, Scott; Stoica, Sabin; Stone, Sheldon; Storaci, Barbara; Stracka, Simone; Straticiuc, Mihai; Straumann, Ulrich; Stroili, Roberto; Subbiah, Vijay Kartik; Sun, Liang; Sutcliffe, William; Swientek, Krzysztof; Swientek, Stefan; Syropoulos, Vasileios; Szczekowski, Marek; Szczypka, Paul; Szilard, Daniela; Szumlak, Tomasz; T'Jampens, Stephane; Teklishyn, Maksym; Tellarini, Giulia; Teubert, Frederic; Thomas, Christopher; Thomas, Eric; van Tilburg, Jeroen; Tisserand, Vincent; Tobin, Mark; Tolk, Siim; Tomassetti, Luca; Topp-Joergensen, Stig; Torr, Nicholas; Tournefier, Edwige; Tourneur, Stephane; Tran, Minh Tâm; Tresch, Marco; Tsaregorodtsev, Andrei; Tsopelas, Panagiotis; Tuning, Niels; Ubeda Garcia, Mario; Ukleja, Artur; Ustyuzhanin, Andrey; Uwer, Ulrich; Vacca, Claudia; Vagnoni, Vincenzo; Valenti, Giovanni; Vallier, Alexis; Vazquez Gomez, Ricardo; Vazquez Regueiro, Pablo; Vázquez Sierra, Carlos; Vecchi, Stefania; Velthuis, Jaap; Veltri, Michele; Veneziano, Giovanni; Vesterinen, Mika; Viaud, Benoit; Vieira, Daniel; Vieites Diaz, Maria; Vilasis-Cardona, Xavier; Vollhardt, Achim; Volyanskyy, Dmytro; Voong, David; Vorobyev, Alexey; Vorobyev, Vitaly; Voß, Christian; Voss, Helge; de Vries, Jacco; Waldi, Roland; Wallace, Charlotte; Wallace, Ronan; Walsh, John; Wandernoth, Sebastian; Wang, Jianchun; Ward, David; Watson, Nigel; Websdale, David; Whitehead, Mark; Wicht, Jean; Wiedner, Dirk; Wilkinson, Guy; Williams, Matthew; Williams, Mike; Wilschut, Hans; Wilson, Fergus; Wimberley, Jack; Wishahi, Julian; Wislicki, Wojciech; Witek, Mariusz; Wormser, Guy; Wotton, Stephen; Wright, Simon; Wyllie, Kenneth; Xie, Yuehong; Xing, Zhou; Xu, Zhirui; Yang, Zhenwei; Yuan, Xuhao; Yushchenko, Oleg; Zangoli, Maria; Zavertyaev, Mikhail; Zhang, Liming; Zhang, Wen Chao; Zhang, Yanxi; Zhelezov, Alexey; Zhokhov, Anatoly; Zhong, Liang; Zvyagin, Alexander

    2015-01-01

    Using the latest LHCb measurements of time-dependent $C\\!P$ violation in the $B^0_s \\to K^+K^-$ decay, a U-spin relation between the decay amplitudes of $B^0_s \\to K^+K^-$ and $B^0\\to \\pi^+\\pi^-$ decay processes allows constraints to be placed on the angle $\\gamma$ of the unitarity triangle and on the $B^0_s$ mixing phase $-2\\beta_s$. Results from an extended approach, which uses additional inputs on $B^0\\to \\pi^0\\pi^0$ and $B^+\\to \\pi^+\\pi^0$ decays from other experiments and exploits isospin symmetry, are also presented. The dependence of the results on the maximum allowed amount of U-spin breaking is studied. At 68% probability, the value $\\gamma = \\left( 63.5^{\\,+\\, 7.2}_{\\,-\\,6.7} \\right)^\\circ~\\mathrm{modulo}~180^\\circ$ is determined. In an alternative analysis, the value $-2\\beta_s = -0.12 ^{\\,+\\,0.14}_{\\,-\\,0.16}\\,\\,\\mathrm{rad}$ is found. In both measurements, the uncertainties due to U-spin breaking effects up to 50% are included.

  18. Determination of $\\gamma$ and $-2\\beta_s$ from charmless two-body decays of beauty mesons

    CERN Document Server

    Aaij, Roel; Adeva, Bernardo; Adinolfi, Marco; Affolder, Anthony; Ajaltouni, Ziad; Akar, Simon; Albrecht, Johannes; Alessio, Federico; Alexander, Michael; Ali, Suvayu; Alkhazov, Georgy; Alvarez Cartelle, Paula; Alves Jr, Antonio Augusto; Amato, Sandra; Amerio, Silvia; Amhis, Yasmine; An, Liupan; Anderlini, Lucio; Anderson, Jonathan; Andreassen, Rolf; Andreotti, Mirco; Andrews, Jason; Appleby, Robert; Aquines Gutierrez, Osvaldo; Archilli, Flavio; Artamonov, Alexander; Artuso, Marina; Aslanides, Elie; Auriemma, Giulio; Baalouch, Marouen; Bachmann, Sebastian; Back, John; Badalov, Alexey; Baesso, Clarissa; Baldini, Wander; Barlow, Roger; Barschel, Colin; Barsuk, Sergey; Barter, William; Batozskaya, Varvara; Battista, Vincenzo; Bay, Aurelio; Beaucourt, Leo; Beddow, John; Bedeschi, Franco; Bediaga, Ignacio; Belogurov, Sergey; Belous, Konstantin; Belyaev, Ivan; Ben-Haim, Eli; Bencivenni, Giovanni; Benson, Sean; Benton, Jack; Berezhnoy, Alexander; Bernet, Roland; Bettler, Marc-Olivier; van Beuzekom, Martinus; Bien, Alexander; Bifani, Simone; Bird, Thomas; Bizzeti, Andrea; Bjørnstad, Pål Marius; Blake, Thomas; Blanc, Frédéric; Blouw, Johan; Blusk, Steven; Bocci, Valerio; Bondar, Alexander; Bondar, Nikolay; Bonivento, Walter; Borghi, Silvia; Borgia, Alessandra; Borsato, Martino; Bowcock, Themistocles; Bowen, Espen Eie; Bozzi, Concezio; Brambach, Tobias; Bressieux, Joël; Brett, David; Britsch, Markward; Britton, Thomas; Brodzicka, Jolanta; Brook, Nicholas; Brown, Henry; Bursche, Albert; Busetto, Giovanni; Buytaert, Jan; Cadeddu, Sandro; Calabrese, Roberto; Calvi, Marta; Calvo Gomez, Miriam; Campana, Pierluigi; Campora Perez, Daniel; Carbone, Angelo; Carboni, Giovanni; Cardinale, Roberta; Cardini, Alessandro; Carson, Laurence; Carvalho Akiba, Kazuyoshi; Casse, Gianluigi; Cassina, Lorenzo; Castillo Garcia, Lucia; Cattaneo, Marco; Cauet, Christophe; Cenci, Riccardo; Charles, Matthew; Charpentier, Philippe; Chefdeville, Maximilien; Chen, Shanzhen; Cheung, Shu-Faye; Chiapolini, Nicola; Chrzaszcz, Marcin; Ciba, Krzystof; Cid Vidal, Xabier; Ciezarek, Gregory; Clarke, Peter; Clemencic, Marco; Cliff, Harry; Closier, Joel; Coco, Victor; Cogan, Julien; Cogneras, Eric; Cojocariu, Lucian; Collins, Paula; Comerma-Montells, Albert; Contu, Andrea; Cook, Andrew; Coombes, Matthew; Coquereau, Samuel; Corti, Gloria; Corvo, Marco; Counts, Ian; Couturier, Benjamin; Cowan, Greig; Craik, Daniel Charles; Cruz Torres, Melissa Maria; Cunliffe, Samuel; Currie, Robert; D'Ambrosio, Carmelo; Dalseno, Jeremy; David, Pascal; David, Pieter; Davis, Adam; De Bruyn, Kristof; De Capua, Stefano; De Cian, Michel; De Miranda, Jussara; De Paula, Leandro; De Silva, Weeraddana; De Simone, Patrizia; Decamp, Daniel; Deckenhoff, Mirko; Del Buono, Luigi; Déléage, Nicolas; Derkach, Denis; Deschamps, Olivier; Dettori, Francesco; Di Canto, Angelo; Dijkstra, Hans; Donleavy, Stephanie; Dordei, Francesca; Dorigo, Mirco; Dosil Suárez, Alvaro; Dossett, David; Dovbnya, Anatoliy; Dreimanis, Karlis; Dujany, Giulio; Dupertuis, Frederic; Durante, Paolo; Dzhelyadin, Rustem; Dziurda, Agnieszka; Dzyuba, Alexey; Easo, Sajan; Egorychev, Victor; Eidelman, Semen; Eisenhardt, Stephan; Eitschberger, Ulrich; Ekelhof, Robert; Eklund, Lars; El Rifai, Ibrahim; Elsasser, Christian; Ely, Scott; Esen, Sevda; Evans, Hannah Mary; Evans, Timothy; Falabella, Antonio; Färber, Christian; Farinelli, Chiara; Farley, Nathanael; Farry, Stephen; Fay, Robert; Ferguson, Dianne; Fernandez Albor, Victor; Ferreira Rodrigues, Fernando; Ferro-Luzzi, Massimiliano; Filippov, Sergey; Fiore, Marco; Fiorini, Massimiliano; Firlej, Miroslaw; Fitzpatrick, Conor; Fiutowski, Tomasz; Fol, Philip; Fontana, Marianna; Fontanelli, Flavio; Forty, Roger; Francisco, Oscar; Frank, Markus; Frei, Christoph; Frosini, Maddalena; Fu, Jinlin; Furfaro, Emiliano; Gallas Torreira, Abraham; Galli, Domenico; Gallorini, Stefano; Gambetta, Silvia; Gandelman, Miriam; Gandini, Paolo; Gao, Yuanning; García Pardiñas, Julián; Garofoli, Justin; Garra Tico, Jordi; Garrido, Lluis; Gaspar, Clara; Gauld, Rhorry; Gavardi, Laura; Gavrilov, Gennadii; Geraci, Angelo; Gersabeck, Evelina; Gersabeck, Marco; Gershon, Timothy; Ghez, Philippe; Gianelle, Alessio; Gianì, Sebastiana; Gibson, Valerie; Giubega, Lavinia-Helena; Gligorov, V.V.; Göbel, Carla; Golubkov, Dmitry; Golutvin, Andrey; Gomes, Alvaro; Gotti, Claudio; Grabalosa Gándara, Marc; Graciani Diaz, Ricardo; Granado Cardoso, Luis Alberto; Graugés, Eugeni; Graziani, Giacomo; Grecu, Alexandru; Greening, Edward; Gregson, Sam; Griffith, Peter; Grillo, Lucia; Grünberg, Oliver; Gui, Bin; Gushchin, Evgeny; Guz, Yury; Gys, Thierry; Hadjivasiliou, Christos; Haefeli, Guido; Haen, Christophe; Haines, Susan; Hall, Samuel; Hamilton, Brian; Hampson, Thomas; Han, Xiaoxue; Hansmann-Menzemer, Stephanie; Harnew, Neville; Harnew, Samuel; Harrison, Jonathan; He, Jibo; Head, Timothy; Heijne, Veerle; Hennessy, Karol; Henrard, Pierre; Henry, Louis; Hernando Morata, Jose Angel; van Herwijnen, Eric; Heß, Miriam; Hicheur, Adlène; Hill, Donal; Hoballah, Mostafa; Hombach, Christoph; Hulsbergen, Wouter; Hunt, Philip; Hussain, Nazim; Hutchcroft, David; Hynds, Daniel; Idzik, Marek; Ilten, Philip; Jacobsson, Richard; Jaeger, Andreas; Jalocha, Pawel; Jans, Eddy; Jaton, Pierre; Jawahery, Abolhassan; Jing, Fanfan; John, Malcolm; Johnson, Daniel; Jones, Christopher; Joram, Christian; Jost, Beat; Jurik, Nathan; Kaballo, Michael; Kandybei, Sergii; Kanso, Walaa; Karacson, Matthias; Karbach, Moritz; Karodia, Sarah; Kelsey, Matthew; Kenyon, Ian; Ketel, Tjeerd; Khanji, Basem; Khurewathanakul, Chitsanu; Klaver, Suzanne; Klimaszewski, Konrad; Kochebina, Olga; Kolpin, Michael; Komarov, Ilya; Koopman, Rose; Koppenburg, Patrick; Korolev, Mikhail; Kozlinskiy, Alexandr; Kravchuk, Leonid; Kreplin, Katharina; Kreps, Michal; Krocker, Georg; Krokovny, Pavel; Kruse, Florian; Kucewicz, Wojciech; Kucharczyk, Marcin; Kudryavtsev, Vasily; Kurek, Krzysztof; Kvaratskheliya, Tengiz; La Thi, Viet Nga; Lacarrere, Daniel; Lafferty, George; Lai, Adriano; Lambert, Dean; Lambert, Robert W; Lanfranchi, Gaia; Langenbruch, Christoph; Langhans, Benedikt; Latham, Thomas; Lazzeroni, Cristina; Le Gac, Renaud; van Leerdam, Jeroen; Lees, Jean-Pierre; Lefèvre, Regis; Leflat, Alexander; Lefrançois, Jacques; Leo, Sabato; Leroy, Olivier; Lesiak, Tadeusz; Leverington, Blake; Li, Yiming; Likhomanenko, Tatiana; Liles, Myfanwy; Lindner, Rolf; Linn, Christian; Lionetto, Federica; Liu, Bo; Lohn, Stefan; Longstaff, Iain; Lopes, Jose; Lopez-March, Neus; Lowdon, Peter; Lu, Haiting; Lucchesi, Donatella; Luo, Haofei; Lupato, Anna; Luppi, Eleonora; Lupton, Oliver; Machefert, Frederic; Machikhiliyan, Irina V; Maciuc, Florin; Maev, Oleg; Malde, Sneha; Malinin, Alexander; Manca, Giulia; Mancinelli, Giampiero; Mapelli, Alessandro; Maratas, Jan; Marchand, Jean François; Marconi, Umberto; Marin Benito, Carla; Marino, Pietro; Märki, Raphael; Marks, Jörg; Martellotti, Giuseppe; Martens, Aurelien; Martín Sánchez, Alexandra; Martinelli, Maurizio; Martinez Santos, Diego; Martinez Vidal, Fernando; Martins Tostes, Danielle; Massafferri, André; Matev, Rosen; Mathe, Zoltan; Matteuzzi, Clara; Mazurov, Alexander; McCann, Michael; McCarthy, James; McNab, Andrew; McNulty, Ronan; McSkelly, Ben; Meadows, Brian; Meier, Frank; Meissner, Marco; Merk, Marcel; Milanes, Diego Alejandro; Minard, Marie-Noelle; Moggi, Niccolò; Molina Rodriguez, Josue; Monteil, Stephane; Morandin, Mauro; Morawski, Piotr; Mordà, Alessandro; Morello, Michael Joseph; Moron, Jakub; Morris, Adam Benjamin; Mountain, Raymond; Muheim, Franz; Müller, Katharina; Mussini, Manuel; Muster, Bastien; Naik, Paras; Nakada, Tatsuya; Nandakumar, Raja; Nasteva, Irina; Needham, Matthew; Neri, Nicola; Neubert, Sebastian; Neufeld, Niko; Neuner, Max; Nguyen, Anh Duc; Nguyen, Thi-Dung; Nguyen-Mau, Chung; Nicol, Michelle; Niess, Valentin; Niet, Ramon; Nikitin, Nikolay; Nikodem, Thomas; Novoselov, Alexey; O'Hanlon, Daniel Patrick; Oblakowska-Mucha, Agnieszka; Obraztsov, Vladimir; Oggero, Serena; Ogilvy, Stephen; Okhrimenko, Oleksandr; Oldeman, Rudolf; Onderwater, Gerco; Orlandea, Marius; Otalora Goicochea, Juan Martin; Owen, Patrick; Oyanguren, Maria Arantza; Pal, Bilas Kanti; Palano, Antimo; Palombo, Fernando; Palutan, Matteo; Panman, Jacob; Papanestis, Antonios; Pappagallo, Marco; Pappalardo, Luciano; Parkes, Christopher; Parkinson, Christopher John; Passaleva, Giovanni; Patel, Girish; Patel, Mitesh; Patrignani, Claudia; Pazos Alvarez, Antonio; Pearce, Alex; Pellegrino, Antonio; Pepe Altarelli, Monica; Perazzini, Stefano; Perez Trigo, Eliseo; Perret, Pascal; Perrin-Terrin, Mathieu; Pescatore, Luca; Pesen, Erhan; Petridis, Konstantin; Petrolini, Alessandro; Picatoste Olloqui, Eduardo; Pietrzyk, Boleslaw; Pilař, Tomas; Pinci, Davide; Pistone, Alessandro; Playfer, Stephen; Plo Casasus, Maximo; Polci, Francesco; Poluektov, Anton; Polycarpo, Erica; Popov, Alexander; Popov, Dmitry; Popovici, Bogdan; Potterat, Cédric; Price, Eugenia; Price, Joseph David; Prisciandaro, Jessica; Pritchard, Adrian; Prouve, Claire; Pugatch, Valery; Puig Navarro, Albert; Punzi, Giovanni; Qian, Wenbin; Rachwal, Bartolomiej; Rademacker, Jonas; Rakotomiaramanana, Barinjaka; Rama, Matteo; Rangel, Murilo; Raniuk, Iurii; Rauschmayr, Nathalie; Raven, Gerhard; Redi, Federico; Reichert, Stefanie; Reid, Matthew; dos Reis, Alberto; Ricciardi, Stefania; Richards, Sophie; Rihl, Mariana; Rinnert, Kurt; Rives Molina, Vincente; Robbe, Patrick; Rodrigues, Ana Barbara; Rodrigues, Eduardo; Rodriguez Perez, Pablo; Roiser, Stefan; Romanovsky, Vladimir; Romero Vidal, Antonio; Rotondo, Marcello; Rouvinet, Julien; Ruf, Thomas; Ruiz, Hugo; Ruiz Valls, Pablo; Saborido Silva, Juan Jose; Sagidova, Naylya; Sail, Paul; Saitta, Biagio; Salustino Guimaraes, Valdir; Sanchez Mayordomo, Carlos; Sanmartin Sedes, Brais; Santacesaria, Roberta; Santamarina Rios, Cibran; Santovetti, Emanuele; Sarti, Alessio; Satriano, Celestina; Satta, Alessia; Saunders, Daniel Martin; Savrie, Mauro; Savrina, Darya; Schiller, Manuel; Schindler, Heinrich; Schlupp, Maximilian; Schmelling, Michael; Schmidt, Burkhard; Schneider, Olivier; Schopper, Andreas; Schune, Marie Helene; Schwemmer, Rainer; Sciascia, Barbara; Sciubba, Adalberto; Seco, Marcos; Semennikov, Alexander; Sepp, Indrek; Serra, Nicola; Serrano, Justine; Sestini, Lorenzo; Seyfert, Paul; Shapkin, Mikhail; Shapoval, Illya; Shcheglov, Yury; Shears, Tara; Shekhtman, Lev; Shevchenko, Vladimir; Shires, Alexander; Silva Coutinho, Rafael; Simi, Gabriele; Sirendi, Marek; Skidmore, Nicola; Skwarnicki, Tomasz; Smith, Anthony; Smith, Edmund; Smith, Eluned; Smith, Jackson; Smith, Mark; Snoek, Hella; Sokoloff, Michael; Soler, Paul; Soomro, Fatima; Souza, Daniel; Souza De Paula, Bruno; Spaan, Bernhard; Sparkes, Ailsa; Spradlin, Patrick; Sridharan, Srikanth; Stagni, Federico; Stahl, Marian; Stahl, Sascha; Steinkamp, Olaf; Stenyakin, Oleg; Stevenson, Scott; Stoica, Sabin; Stone, Sheldon; Storaci, Barbara; Stracka, Simone; Straticiuc, Mihai; Straumann, Ulrich; Stroili, Roberto; Subbiah, Vijay Kartik; Sun, Liang; Sutcliffe, William; Swientek, Krzysztof; Swientek, Stefan; Syropoulos, Vasileios; Szczekowski, Marek; Szczypka, Paul; Szilard, Daniela; Szumlak, Tomasz; T'Jampens, Stephane; Teklishyn, Maksym; Tellarini, Giulia; Teubert, Frederic; Thomas, Christopher; Thomas, Eric; van Tilburg, Jeroen; Tisserand, Vincent; Tobin, Mark; Tolk, Siim; Tomassetti, Luca; Topp-Joergensen, Stig; Torr, Nicholas; Tournefier, Edwige; Tourneur, Stephane; Tran, Minh Tâm; Tresch, Marco; Tsaregorodtsev, Andrei; Tsopelas, Panagiotis; Tuning, Niels; Ubeda Garcia, Mario; Ukleja, Artur; Ustyuzhanin, Andrey; Uwer, Ulrich; Vacca, Claudia; Vagnoni, Vincenzo; Valenti, Giovanni; Vallier, Alexis; Vazquez Gomez, Ricardo; Vazquez Regueiro, Pablo; Vázquez Sierra, Carlos; Vecchi, Stefania; Velthuis, Jaap; Veltri, Michele; Veneziano, Giovanni; Vesterinen, Mika; Viaud, Benoit; Vieira, Daniel; Vieites Diaz, Maria; Vilasis-Cardona, Xavier; Vollhardt, Achim; Volyanskyy, Dmytro; Voong, David; Vorobyev, Alexey; Vorobyev, Vitaly; Voß, Christian; Voss, Helge; de Vries, Jacco; Waldi, Roland; Wallace, Charlotte; Wallace, Ronan; Walsh, John; Wandernoth, Sebastian; Wang, Jianchun; Ward, David; Watson, Nigel; Websdale, David; Whitehead, Mark; Wicht, Jean; Wiedner, Dirk; Wilkinson, Guy; Williams, Matthew; Williams, Mike; Wilschut, Hans; Wilson, Fergus; Wimberley, Jack; Wishahi, Julian; Wislicki, Wojciech; Witek, Mariusz; Wormser, Guy; Wotton, Stephen; Wright, Simon; Wyllie, Kenneth; Xie, Yuehong; Xing, Zhou; Xu, Zhirui; Yang, Zhenwei; Yuan, Xuhao; Yushchenko, Oleg; Zangoli, Maria; Zavertyaev, Mikhail; Zhang, Liming; Zhang, Wen Chao; Zhang, Yanxi; Zhelezov, Alexey; Zhokhov, Anatoly; Zhong, Liang; Zvyagin, Alexander

    2015-02-04

    Using the latest LHCb measurements of time-dependent $C\\!P$ violation in the $B^0_s \\to K^+K^-$ decay, a U-spin relation between the decay amplitudes of $B^0_s \\to K^+K^-$ and $B^0\\to \\pi^+\\pi^-$ decay processes allows constraints to be placed on the angle $\\gamma$ of the unitarity triangle and on the $B^0_s$ mixing phase $-2\\beta_s$. Results from an extended approach, which uses additional inputs on $B^0\\to \\pi^0\\pi^0$ and $B^+\\to \\pi^+\\pi^0$ decays from other experiments and exploits isospin symmetry, are also presented. The dependence of the results on the maximum allowed amount of U-spin breaking is studied. At 68% probability, the value $\\gamma = \\left( 63.5^{\\,+\\, 7.2}_{\\,-\\,6.7} \\right)^\\circ~\\mathrm{modulo}~180^\\circ$ is determined. In an alternative analysis, the value $-2\\beta_s = -0.12 ^{\\,+\\,0.14}_{\\,-\\,0.16}\\,\\,\\mathrm{rad}$ is found. In both measurements, the uncertainties due to U-spin breaking effects up to 50% are included.

  19. The ENSDF based radionuclide source for MCNP

    International Nuclear Information System (INIS)

    Berlizov, A.N.; Tryshyn, V.V.

    2003-01-01

    A utility for generating source code of the Source subroutine of MCNP (a general Monte Carlo NxParticle transport code) on the basis of ENSDF (Evaluated Nuclear Structure Data File) is described. The generated code performs statistical simulation of processes, accompanying radioactive decay of a chosen radionuclide through a specified decay branch, providing characteristics of emitted correlated particles on its output. At modeling the following processes are taken into account: emission of continuum energy electrons at beta - -decay to different exited levels of a daughter nucleus; annihilation photon emission accompanying beta + -decay; gamma-ray emission; emission of discrete energy electrons resulted from internal conversion process on atomic K- and L I,II,III -shells; K and LX-ray emission at single and double fluorescence, accompanying electron capture and internal conversion processes. Number of emitted particles, their types, energies and emission times are sampled according to characteristics of a decay scheme of a particular radionuclide as well as characteristics of atomic shells of mother and daughter nuclei. Angular correlations, calculated for a particular combination of nuclear level spins, mixing ratios and gamma-ray multipolarities, are taken into account at sampling of directional cosines of emitted gamma-rays. The paper contains examples of spectrometry system response simulation at measurements with real radionuclide sources. (authors)

  20. Monte Carlo dose characterization of a new 90Sr/90Y source with balloon for intravascular brachytherapy

    International Nuclear Information System (INIS)

    Wang Ruqing; Li, X. Allen; Lobdell, John

    2003-01-01

    Beta emitting source wires or seeds have been adopted in clinical practice of intravascular brachytherapy for coronary vessels. Due to the limitation of penetration depth, this type of source is normally not applicable to treat vessels with large diameter, e.g., peripheral vessel. In the effort to extend application of its beta source for peripheral vessels, Novoste has recently developed a new catheter-based system, the Corona trade mark sign 90 Sr/ 90 Y system. It is a source train of 6 cm length and is jacketed by a balloon. The existence of the balloon increases the penetration of the beta particles and maintains the source within a location away from the vessel wall. Using the EGSnrc Monte Carlo system, we have calculated the two-dimensional (2-D) dose rate distribution of the Corona trade mark sign system in water for a balloon diameter of 5 mm. The dose rates on the transverse axis obtained in this study are in good agreement with calibration results of the National Institute of Standards and Technology for the same system for balloon diameters of 5 and 8 mm. Features of the 2-D dose field were studied in detail. The dose parameters based on AAPM TG-60 protocol were derived. For a balloon diameter of 5 mm, the dose rate at the reference point (defined as r 0 =4.5 mm, 2 mm from the balloon surface) is found to be 0.010 28 Gy min -1 mCi -1 . A new formalism for a better characterization of this long source is presented. Calculations were also performed for other balloon diameters. The dosimetry for this source is compared with a 192 Ir source, commonly used for peripheral arteries. In conclusion, we have performed a detailed dosimetric characterization for a new beta source for peripheral vessels. Our study shows that, from dosimetric point of view, the Corona trade mark sign system can be used for the treatment of an artery with a large diameter, e.g., peripheral vessel