WorldWideScience

Sample records for berkeley power station

  1. Stanwell power station project

    Energy Technology Data Exchange (ETDEWEB)

    Mills, David R; J Dey, Christopher [University of Sidney, Sidney (Australia); Morrison, Graham L [University of New South Wales, Sidney (Australia)

    2000-07-01

    This paper describes the Compact Linear Fresnel Reflector (CLFR) being developed for installation at the Stanwell power station in Queensland Australia. Stanwell Corporation Limited (SCL). Solahart International, Solsearch Pty. Ltd. And the universities of Sidney and New South Wales are cooperating in the project, and this first plant being partly funded by the Australian Greenhouse Office. The solar plant will be attached to a 1440 MW(e) coal fired plant. The 17000 m{sup 2} array will be the largest array in Australia, producing a peak of 13 MW of thermal energy which will offset the use of coal in the generation of electricity. It will use direct steam generation and will feed either steam or hot water at 265 Celsius degrees directly into the power station preheating cycle. The CLFR system, first developed by the University of Sidney and Solsearch Pty. Ltd., is simple and offers small reflector size, low structural cost, fixed receiver geometry. Initial installed plant costs are approximately US$1000 per kWe, but this includes the effect of high up-front design costs and the cost should drop substantially in the second and subsequent plants. [Spanish] Proyecto de la Planta Electrica Stanwell este articulo describe el Reflector Lineal Compacto Fresnel (CLFR, siglas en ingles) que se esta desarrollando para la instalacion de la planta electrica Stanwell en Queensland, Australia. La Corporacion Stanwell Limited (SCL), Solahart International, Solsearch Pty. Ltd., las universidades de Sidney y de New South Wales estan cooperando en este proyecto, y esta primera planta esta parcialmente auspiciada por la Australian Greenhouse Office. La planta solar sera anexa a una planta de carbon de 1440 MW(e). Este arreglo de 17000 m{sup 2} sera el mayor en Australia y producira un maximo de 13 MW en energia termica la cual contrarrestara el uso del carbon en la generacion de electricidad. Utilizara generacion con vapor directo y alimentara ya sea vapor o agua caliente a 265 grados

  2. Package power stations for export

    Energy Technology Data Exchange (ETDEWEB)

    1985-01-01

    The cheap and efficient generation of power is an essential requirement for the success and prosperity of any community and is especially important to third world countries. It is therefore logical that the more technologically advanced nations should seek to produce power stations for the developing countries. Power plant can now be designed into a packaged form that may be readily exported and commissioned. This valuable and interesting collection of papers were originally presented at a seminar organised by the Power Industries Division of the Institution of Mechanical Engineers. Topics considered include the developing world market for packaged power stations using indigenous fuels; multi-fuel systems for power generation; packaging, modularisation, and containerisation of equipment for power boilers for export; compact coal-fired industrial plant; rural woodburning power stations; biomass gasification based power generation technology and potential; gas fed reciprocating engine development; packaged heavy duty gas turbines for power generation; and criteria for assessing the appropriateness of package power technologies in developing countries.

  3. Earthquake alarm; operating the seismograph station at the University of California, Berkeley.

    Science.gov (United States)

    Stump, B.

    1980-01-01

    An alarm bell rings at the seismographic station and at the office of the campus police. It is 3:00 on a foggy San Francisco morning. Somewhere in the world an earthquake has occurred. The police telephone the duty seismologist at home telling him that the alarm has triggered. He makes his way into the seismograph station, bathrobe and all, to locate the earthquake and determine its magnitude. In this way, many seismology graduate students have been initiated into the responsibilities of running a seismographic station

  4. Thermoelectrical power stations in 1967

    Energy Technology Data Exchange (ETDEWEB)

    Medici, M. (University of Padova, Italy)

    1968-01-01

    In Italy in 1967, geothermal electric power production was 2.66% of the national energy production. The implementation of traditional and nuclear power plants is described. The trend in conventional thermoelectric power plants is characterized by ever-increasing block capacities (100-160 MW at present), they are expected to increase to 600 MW in Europe and to 1200 MW in the USA 10 years from now. Nuclear power plants with pressurized-water reactors, boiling-water reactors, and graphite-gas reactors have been built recently in Italy. Studies are being conducted in the area of high-speed reactors and breeder reactors. A description is presented of a power station using geothermal energy. At the end of 1967, geothermal power plants with an electrical capacity of 340 MW were in operation. Generally, U.S. thermoelectrical engine blocks with high productivity were used. The thermodynamic characteristics of these blocks are described in detail. The most powerful engine in the field in Italy- a turbocompressore Franco Tosi- was constructed in the ENEL central Castlenuovo Val Cecina in the Larderello region. The compressor is fed by a combined flow of steam, CO/sub 2/ and H/sub 2/S. It is characterized by a load of 22 t/h and an input pressure of 0.0905 atm at the outlet. The absorbed power is 2.28 MW at a velocity of 50 rotations/sec. Thirty figures are presented.

  5. Nagymaros power station on the River Danube

    Energy Technology Data Exchange (ETDEWEB)

    Kobilka, J.

    1987-02-01

    This article deals with the economic aspects of Austrian cooperation in power station construction as practised in the consulting activities of Oesterreichische Donaukraftwerke AG, and discusses in detail this company's participation in the construction of the main structure for the Nagymaros power station on the Danube under a general contract.

  6. Micro hydro-electric power stations

    Energy Technology Data Exchange (ETDEWEB)

    Monition, L.; Le Nir, M.; Roux, J.

    1984-01-01

    This book provides a discussion of all aspects of hydro-power exploitation using micro-power stations. It offers guidance to techniques for assessing the power available from a given stream, designing and building siteworks, selecting the appropriate turbine types for given conditions, and measuring and controlling environmental hazards associated with micro-hydro installations.

  7. case study of afam power station

    African Journals Online (AJOL)

    NIJOTECH

    checking of emergency failure of components or .... 1, 2002. Madueme. 87. Table 7: History of Afam generating plans from 1962 to 1997 ... was no maintenance management section in the power station ... Training School, 1998. 5. Clifton, R.N. ...

  8. Power electronic applications for Space Station Freedom

    Science.gov (United States)

    Pickrell, Roy L.; Lazbin, Igor

    1990-01-01

    NASA plans to orbit a permanently manned space station in the late 1990s, which requires development and assembly of a photovoltaic (PV) power source system to supply up to 75 kW of electrical power average during the orbital period. The electrical power requirements are to be met by a combination of PV source, storage, and control elements for the sun and eclipse periods. The authors discuss the application of power electronics and controls to manage the generation, storage, and distribution of power to meet the station loads, as well as the computer models used for analysis and simulation of the PV power system. The requirements for power source integrated controls to adjust storage charge power during the insolation period current limiting, breaker interrupt current values, and the electrical fault protection approach are defined. Based on these requirements, operating concepts have been defined which then become drivers for specific system and element design.

  9. Nuclear power generation modern power station practice

    CERN Document Server

    1971-01-01

    Nuclear Power Generation focuses on the use of nuclear reactors as heat sources for electricity generation. This volume explains how nuclear energy can be harnessed to produce power by discussing the fundamental physical facts and the properties of matter underlying the operation of a reactor. This book is comprised of five chapters and opens with an overview of nuclear physics, first by considering the structure of matter and basic physical concepts such as atomic structure and nuclear reactions. The second chapter deals with the requirements of a reactor as a heat source, along with the diff

  10. Lunar Base Thermoelectric Power Station Study

    Science.gov (United States)

    Determan, William; Frye, Patrick; Mondt, Jack; Fleurial, Jean-Pierre; Johnson, Ken; Stapfer, Gerhard; Brooks, Michael; Heshmatpour, Ben

    2006-01-01

    Under NASA's Project Prometheus, the Nuclear Space Power Systems Program, the Jet Propulsion Laboratory, Pratt & Whitney Rocketdyne, and Teledyne Energy Systems have teamed with a number of universities, under the Segmented Thermoelectric Multicouple Converter (STMC) Task, to develop the next generation of advanced thermoelectric converters for space reactor power systems. Work on the STMC converter assembly has progressed to the point where the lower temperature stage of the segmented multicouple converter assembly is ready for laboratory testing, and promising candidates for the upper stage materials have been identified and their properties are being characterized. One aspect of the program involves mission application studies to help define the potential benefits from the use of these STMC technologies for designated NASA missions such as a lunar base power station where kilowatts of power would be required to maintain a permanent manned presence on the surface of the moon. A modular 50 kWe thermoelectric power station concept was developed to address a specific set of requirements developed for this particular mission concept. Previous lunar lander concepts had proposed the use of lunar regolith as in-situ radiation shielding material for a reactor power station with a one kilometer exclusion zone radius to minimize astronaut radiation dose rate levels. In the present concept, we will examine the benefits and requirements for a hermetically-sealed reactor thermoelectric power station module suspended within a man-made lunar surface cavity. The concept appears to maximize the shielding capabilities of the lunar regolith while minimizing its handling requirements. Both thermal and nuclear radiation levels from operation of the station, at its 100-m exclusion zone radius, were evaluated and found to be acceptable. Site preparation activities are reviewed as well as transport issues for this concept. The goal of the study was to review the entire life cycle of the

  11. Water turbine technology for small power stations

    Science.gov (United States)

    Salovaara, T.

    1980-02-01

    The paper examines hydro-power stations and the efficiency and costs of using water turbines to run them. Attention is given to different turbine types emphasizing the use of Kaplan-turbines and runners. Hydraulic characteristics and mechanical properties of low head turbines and small turbines, constructed of fully fabricated steel plate structures, are presented.

  12. Toluene stability Space Station Rankine power system

    Science.gov (United States)

    Havens, V. N.; Ragaller, D. R.; Sibert, L.; Miller, D.

    1987-01-01

    A dynamic test loop is designed to evaluate the thermal stability of an organic Rankine cycle working fluid, toluene, for potential application to the Space Station power conversion unit. Samples of the noncondensible gases and the liquid toluene were taken periodically during the 3410 hour test at 750 F peak temperature. The results obtained from the toluene stability loop verify that toluene degradation will not lead to a loss of performance over the 30-year Space Station mission life requirement. The identity of the degradation products and the low rates of formation were as expected from toluene capsule test data.

  13. Numerical flow analysis of hydro power stations

    Science.gov (United States)

    Ostermann, Lars; Seidel, Christian

    2017-07-01

    For the hydraulic engineering and design of hydro power stations and their hydraulic optimisation, mainly experimental studies of the physical submodel or of the full model at the hydraulics laboratory are carried out. Partially, the flow analysis is done by means of computational fluid dynamics based on 2D and 3D methods and is a useful supplement to experimental studies. For the optimisation of hydro power stations, fast numerical methods would be appropriate to study the influence of a wide field of optimisation parameters and flow states. Among the 2D methods, especially the methods based on the shallow water equations are suitable for this field of application, since a lot of experience verified by in-situ measurements exists because of the widely used application of this method for the problems in hydraulic engineering. As necessary, a 3D model may supplement subsequently the optimisation of the hydro power station. The quality of the results of the 2D method for the optimisation of hydro power plants is investigated by means of the results of the optimisation of the hydraulic dividing pier compared to the results of the 3D flow analysis.

  14. Practical design considerations for photovoltaic power station

    Science.gov (United States)

    Swanson, T. D.

    Aspects of photovoltaic (PV) technology are discussed along with generic PV design considerations, taking into account the resource sunlight, PV modules and their reliability, questions of PV system design, the support structure subsystem, and a power conditioning unit subsystem. A description is presented of two recent projects which demonstrate the translation of an idea into actual working PV systems. A privately financed project in Denton, Maryland, went on line in early December, 1982, and began providing power to the local utility grid. It represents the first intermediate size, grid-connected, privately financed power station in the U.S. Based on firm quotes, the actual cost of this system is about $13/W peak. The other project, called the PV Breeder, is an energy independent facility which utilizes solar power to make new solar cells. It is also the first large industrial structure completely powered by the sun.

  15. Growing the Space Station's electrical power plant

    Science.gov (United States)

    Sundberg, Gale R.

    For over a decade NASA LeRC has been defining, demonstrating, and evaluating power electronic components and multi-kilowatt, multiply redundant, electrical power systems as part of OAST charter. Whether one considers aircraft (commercial transport/military), Space Station Freedom, growth station, launch vehicles, or the new Human Exploration Initiative, the conclusions remain the same: high frequency AC power distribution and control is superior to all other approaches for achieving a fast, smart, safe, versatile, and growable electrical power system that will meet a wide range of mission options. To meet the cost and operability goals of future aerospace missions that require significantly higher electrical power and longer durations, we must learn to integrate multiple technologies in ways that enhance overall system synergisms. The way NASA is doing business in space electric power is challenged and some approaches for evolving large space vehicles and platforms in well constructed steps to provide safe, ground testable, growable, smart systems that provide simple, replicative logic structures, which enable hardware and software verification, validation, and implementation are proposed. Viewgraphs are included.

  16. Space Station Freedom secondary power wiring requirements

    Science.gov (United States)

    Sawyer, C. R.

    1994-09-01

    Secondary power is produced by DDCU's (direct current to direct current converter units) and routed to and through secondary power distribution assemblies (SPDA's) to loads or tertiary distribution assemblies. This presentation outlines requirements of Space Station Freedom (SSF) EEE (electrical, electronic, and electromechanical) parts wire and the approved electrical wire and cable. The SSF PDRD (Program Definition and Requirements Document) language problems and resolution are reviewed. The cable routing to and from the SPDA's is presented as diagrams and the wire recommendations and characteristics are given.

  17. Special Protection Scheme at BTPS Power Station

    Science.gov (United States)

    Ballal, Makarand Sudhakar; Suryawanshi, Hiralal Murlidhar; Ballal, Deepali Makarand; Mishra, Mahesh Kumar

    2016-03-01

    After 2003 free licensees' act in power sector, it is observed that many power plants from public sector as well as from private sectors are going to be commissioned. The load growth in India is about more than 10% pa. As these plants are going to connect to the power grid, therefore the grid is going to become more complicated. Also the problems related to grid stability are enhanced. There shall be possibilities regarding failure of grid system and under such circumstance it is always desirable to island minimum single generating unit in power plant of specified geographical area. After islanding the generating unit, this unit has to survive not only for the restoration of grid but also for power supply to important consumers. For the grid stability and effective survival of islanded generating unit, it is mandatory to maintain the power balance equation. This paper focuses on the lacunae's observed in implementation of special protection scheme to carry out islanding operation at Bhusawal Thermal Power Station (BTPS) by considering the case studies. The concepts of islanding, load shedding, generator tripping and along with importance of power balance equation is discussed. Efforts are made to provide the solution for the survival of islanding scheme.

  18. Waste heat rejection from geothermal power stations

    Energy Technology Data Exchange (ETDEWEB)

    Robertson, R.C.

    1978-12-01

    This study of waste heat rejection from geothermal power stations is concerned only with the heat rejected from the power cycle. The heat contained in reinjected or otherwise discharged geothermal fluids is not included with the waste heat considered here. The heat contained in the underflow from the flashtanks in such systems is not considered as part of the heat rejected from the power cycle. By following this definition of the waste heat to be rejected, various methods of waste heat dissipation are discussed without regard for the particular arrangement to obtain heat from the geothermal source. Recent conceptual design studies made for 50-MW(e) geothermal power stations at Heber and Niland, California, are of particular interst. The former uses a flashed-steam system and the latter a binary cycle that uses isopentane. In last-quarter 1976 dollars, the total estimated capital costs were about $750/kW and production costs about 50 mills/kWhr. If wet/dry towers were used to conserve 50% of the water evaporation at Heber, production costs would be about 65 mills/kWhr.

  19. Retrofitting automated process control systems at Ukrainian power stations

    Energy Technology Data Exchange (ETDEWEB)

    B.E. Simkin; V.S. Naumchik; B.D. Kozitskii (and others) [OAO L' vovORGRES, Lviv (Ukraine)

    2008-04-15

    Approaches and principles for retrofitting automated process control systems at Ukrainian power stations are considered. The results obtained from retrofitting the monitoring and control system of Unit 9 at the Burshtyn thermal power station are described.

  20. Electrical Power Station Theory. A Course of Technical Information for Electrical Power Station Wireman Apprentices. Revised Edition.

    Science.gov (United States)

    Lane Community Coll., Eugene, OR.

    This third-year course for electrical power station wirer apprentices is a foundation for the study of all aspects of installation and maintenance of power station equipment. It also provides a good technical background as well as the general knowledge essential to power station operator trainees. The course is intended to be equivalent to a…

  1. Solar Powered Radioactive Air Monitoring Stations

    Energy Technology Data Exchange (ETDEWEB)

    Barnett, J. Matthew; Bisping, Lynn E.; Gervais, Todd L.

    2013-10-30

    Environmental monitoring of ambient air for radioactive material is required as stipulated in the PNNL Site radioactive air license. Sampling ambient air at identified preferred locations could not be initially accomplished because utilities were not readily available. Therefore, solar powered environmental monitoring systems were considered as a possible option. PNNL purchased two 24-V DC solar powered environmental monitoring systems which consisted of solar panels, battery banks, and sampling units. During an approximate four month performance evaluation period, the solar stations operated satisfactorily at an on-site test location. They were subsequently relocated to their preferred locations in June 2012 where they continue to function adequately under the conditions found in Richland, Washington.

  2. Conversion options for Peterhead Power Station

    Energy Technology Data Exchange (ETDEWEB)

    Dibble, I.R.; O' Donnell, I.H. [Scottish Hydro-Electric plc, Perth (United Kingdom); Hunt, G.F. [Thermoflow Ltd., Tewkesbury (United Kingdom)

    1999-07-01

    The two gas/oil-fired 660 MW generating sets at Scottish Hydro-Electric's Peterhead Power Station were originally commissioned in 1981/2 and in order to remain competitive it was essential to upgrade the plant. This paper describes the plant performance aspects of a study carried out by Scottish Hydro-Electric to identify the possible routes for plant modification and the associated efficiency of each option. Scottish Hydro-Electric employed the suite of Thermoflow programs to carry out the performance study. These programs had sufficient flexibility to model the performance of the original plant and then to analyse the variety of re-powering options available, using the original accurate modes as the basis. (author)

  3. Commentary: childhood cancer near nuclear power stations

    Directory of Open Access Journals (Sweden)

    Fairlie Ian

    2009-09-01

    Full Text Available Abstract In 2008, the KiKK study in Germany reported a 1.6-fold increase in solid cancers and a 2.2-fold increase in leukemias among children living within 5 km of all German nuclear power stations. The study has triggered debates as to the cause(s of these increased cancers. This article reports on the findings of the KiKK study; discusses past and more recent epidemiological studies of leukemias near nuclear installations around the world, and outlines a possible biological mechanism to explain the increased cancers. This suggests that the observed high rates of infant leukemias may be a teratogenic effect from incorporated radionuclides. Doses from environmental emissions from nuclear reactors to embryos and fetuses in pregnant women near nuclear power stations may be larger than suspected. Hematopoietic tissues appear to be considerably more radiosensitive in embryos/fetuses than in newborn babies. Recommendations for advice to local residents and for further research are made.

  4. Baseline Testing of the Ultracapacitor Enhanced Photovoltaic Power Station

    Science.gov (United States)

    Eichenberg, Dennis J.; Kolacz, John S.; Tavernelli, Paul F.

    2001-01-01

    The NASA John H. Glenn Research Center is developing an advanced ultracapacitor enhanced photovoltaic power station. Goals of this effort include maximizing photovoltaic power generation efficiency and extending the life of photovoltaic energy storage systems. Unique aspects of the power station include the use of a solar tracker, and ultracapacitors for energy storage. The photovoltaic power station is seen as a way to provide electric power in remote locations that would otherwise not have electric power, provide independence form utility systems, reduce pollution, reduce fossil fuel consumption, and reduce operating costs. The work was done under the Hybrid Power Management (HPM) Program, which includes the Hybrid Electric Transit Bus (HETB), and the E-Bike. The power station complements the E-Bike extremely well in that it permits the charging of the vehicle batteries in remote locations. Other applications include scientific research and medical power sources in isolated regions. The power station is an inexpensive approach to advance the state of the art in power technology in a practical application. The project transfers space technology to terrestrial use via nontraditional partners, and provides power system data valuable for future space applications. A description of the ultracapacitor enhanced power station, the results of performance testing and future power station development plans is the subject of this report. The report concludes that the ultracapacitor enhanced power station provides excellent performance, and that the implementation of ultracapacitors in the power system can provide significant performance improvements.

  5. Coal fired power stations and the environment

    Energy Technology Data Exchange (ETDEWEB)

    Jenkins, S.H.

    1982-12-01

    Environmental problems resulting from the use of coal in power stations were discussed in a conference in Copenhagen in August, 1982. Topics included: 1) Discussions of the adverse temperature effects of cooling tower water. The pathogenic amoeba Naegleria fowleri has been isolated in two of eight cooling tower systems; 2) Uses of power plant ash. Dense blocks of the ash have been used to build artificial reefs with, as yet, not adverse effects on the marine community; 3) Long-range transport of particulates which bind heavy metals in the ash; and 4) The effects of acid rain. An examination of the fish status of Scandanavian lakes did not reveal a simple relationship between pH and fishlessness. It was concluded that levels of calcium and aluminum, food supply, genetically determined tolerance and ecological factors have also played a part in the fish regime of acid-affected lakes. The Norwegian attitude is that there are good grounds for thinking acid rain is a global problem implicating the discharge of nitrogen and sulfur oxides and either micropollutants. (JMT)

  6. Modern power station practice incorporating modern power system practice

    CERN Document Server

    Reynolds, PM

    1992-01-01

    This volume contains two additional features which enhance the value of Modern Power Station Practice as a whole: a cumulative subject index and a detailed list of tables of contents for the entire work. The cumulative index provides access to the vast body of information presented in the set, and also indicates at a glance the breadth and depth of the treatment through the use of inclusive page ranges for major topics. In order to allow the reader the greatest flexibility in using the index there are many cross-references. The entries themselves are qualified by up to two descriptive subheadi

  7. User Context Aware Base Station Power Flow Model

    OpenAIRE

    Walsh, Barbara; Farrell, Ronan

    2005-01-01

    At present the testing of power amplifiers within base station transmitters is limited to testing at component level as opposed to testing at the system level. While the detection of catastrophic failure is possible, that of performance degradation is not. This paper proposes a base station model with respect to transmitter output power with the aim of introducing system level monitoring of the power amplifier behaviour within the base station. Our model reflects the expe...

  8. Solar Fridges and Personal Power Grids: How Berkeley Lab is Fighting Global Poverty (LBNL Science at the Theater)

    Energy Technology Data Exchange (ETDEWEB)

    Buluswar, Shashi [Director, LBNL Institute for Globally Transformative Technologies; Gadgil, Ashok

    2012-11-26

    At this November 26, 2012 Science at the Theater, scientists discussed the recently launched LBNL Institute for Globally Transformative Technologies (LIGTT) at Berkeley Lab. LIGTT is an ambitious mandate to discover and develop breakthrough technologies for combating global poverty. It was created with the belief that solutions will require more advanced R&D and a deep understanding of market needs in the developing world. Berkeley Lab's Ashok Gadgil, Shashi Buluswar and seven other LIGTT scientists discussed what it takes to develop technologies that will impact millions of people. These include: 1) Fuel efficient stoves for clean cooking: Our scientists are improving the Berkeley Darfur Stove, a high efficiency stove used by over 20,000 households in Darfur; 2) The ultra-low energy refrigerator: A lightweight, low-energy refrigerator that can be mounted on a bike so crops can survive the trip from the farm to the market; 3) The solar OB suitcase: A low-cost package of the five most critical biomedical devices for maternal and neonatal clinics; 4) UV Waterworks: A device for quickly, safely and inexpensively disinfecting water of harmful microorganisms.

  9. Automated electric power management and control for Space Station Freedom

    Science.gov (United States)

    Dolce, James L.; Mellor, Pamela A.; Kish, James A.

    1990-01-01

    A comprehensive automation design is being developed for Space Station Freedom's electric power system. It strives to increase station productivity by applying expert systems and conventional algorithms to automate power system operation. An integrated approach to the power system command and control problem is defined and used to direct technology development in: diagnosis, security monitoring and analysis, battery management, and cooperative problem-solving for resource allocation. The prototype automated power system is developed using simulations and test-beds.

  10. Modernisation work commences at the Moabit power station

    Energy Technology Data Exchange (ETDEWEB)

    1988-09-01

    A major part of the modernisation programme for existing power stations is the replacement of combustion block 2 at the Moabit power station by a new circulating fluidised-bed combustor, whose reduced emissions of sulphur dioxide, nitrogen oxides and dust eliminate the need for downstream flue-gas desulphurisation.

  11. Electric power management for the International Space Station experiment racks

    Energy Technology Data Exchange (ETDEWEB)

    Burcham, M. [Boeing Missile and Space, Huntsville, AL (United States); Darty, M.A.; Thibodeau, P.E. [McDonnell Douglas Aerospace, Huntsville, AL (United States); Coe, R. [SCI Systems, Inc., Huntsville, AL (United States); Dunn, M. [Europa Ltd., Glenrothes (United Kingdom)

    1995-12-31

    An intelligent, all solid state, electric power management system for International Space Station experiment racks is described. This power system is implemented via redundant internal microcomputers, controlling hybridized solid state power controllers in response to 1553B data bus commands. The solid state power controllers are programmable for current trip level and for normally-open or normally-closed operation.

  12. Technology Being Developed at Lawrence Berkeley National Laboratory: Ultra-Low- Emission Combustion Technologies for Heat and Power Generation

    Science.gov (United States)

    Cheng, Robert K.

    2001-01-01

    The Combustion Technologies Group at Lawrence Berkeley National Laboratory has developed simple, low-cost, yet robust combustion technologies that may change the fundamental design concept of burners for boilers and furnaces, and injectors for gas turbine combustors. The new technologies utilize lean premixed combustion and could bring about significant pollution reductions from commercial and industrial combustion processes and may also improve efficiency. The technologies are spinoffs of two fundamental research projects: An inner-ring burner insert for lean flame stabilization developed for NASA- sponsored reduced-gravity combustion experiments. A low-swirl burner developed for Department of Energy Basic Energy Sciences research on turbulent combustion.

  13. 47 CFR 74.793 - Digital low power TV and TV translator station protection of broadcast stations.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Digital low power TV and TV translator station... DISTRIBUTIONAL SERVICES Low Power TV, TV Translator, and TV Booster Stations § 74.793 Digital low power TV and TV... TV or TV translator station or change the facilities of an existing station will not be accepted...

  14. Station planning and design incorporating modern power system practice

    CERN Document Server

    Martin, PC

    1991-01-01

    The planning and design of new power stations can involve complex interaction between the many engineering disciplines involved as well as environmental, planning, economical, political and social pressures. This volume aims to provide a logical review of the procedures involved in power station development. The engineering aspects are outlined in detail, with examples, showing the basis of the relationships involved together with ""non-engineering"" factors so that the engineer can draw on the information provided for specific projects. The civil engineering and building of power stations are

  15. 75 FR 43915 - Basin Electric Power Cooperative: Deer Creek Station

    Science.gov (United States)

    2010-07-27

    ... purchasing power on the volatile open electric market. The Action Alternative at White Site 1 would be... Rural Utilities Service Basin Electric Power Cooperative: Deer Creek Station AGENCY: Rural Utilities... CFR Part 1794), and the Western Area Power Administration's (Western) NEPA implementing regulations...

  16. SCAP optimization of the Pasajes de San Juan power station

    Energy Technology Data Exchange (ETDEWEB)

    Perez, L.; Perez, J.M.; Cerezo, J.; Catediano, J.; Martin-Sanchez, J.M. [Iberdrola, Bilbao (Spain)

    1995-08-01

    In July 1990 the company Iberduero, now Iberdrola, decided to carry out a development project using the Spanish technology SCAP in the Pasajes de San Juan power plant. This methodology, featured by the utilization of adaptive predictive control methodology, had been successfully applied in order to achieve the optimization of other industrial processes. The ultimate aim of this project was the replacement of the power station conventional control system, with a SCAP control system with a distributed structure able to optimize the electric energy generation process by optimizing power station operation, maximizing efficiency and working life, reducing maintenance costs, and increasing safety and availability. The project was divided into two stages to evaluate the quality of SCAP technology in the control and optimization of a power station. In the present report, the results obtained in the control of the most critical variables during the power station operation are gathered together. Beforehand, and in order to place these results in a suitable context, the project proceedings summarized in the following phases are considered: the SCAP technology; problems in a thermal power plant; and the Pasajes de San Juan power plant and its control system. The results are presented through comparative graphs that show the performance of the SCAP system as compared to the power station conventional control. 17 figs., 4 tabs., 11 refs.

  17. Design of photovoltaic central power station concentrator array

    Energy Technology Data Exchange (ETDEWEB)

    1984-02-01

    A design for a photovoltaic central power station using tracking concentrators has been developed. The 100 MW plant is assumed to be located adjacent to the Saguaro Power Station of Arizona Public Service. The design assumes an advanced Martin Marietta two-axis tracking fresnel lens concentrator. The concentrators are arrayed in 5 MW subfields, each with its own power conditioning unit. The photovoltaic plant output is connected to the existing 115 kV switchyard. The site specific design allows detailed cost estimates for engineering, site preparation, and installation. Collector and power conditioning costs have been treated parametrically.

  18. Pipe rupture incident of Hamaoka Nuclear Power Station Unit-1

    Energy Technology Data Exchange (ETDEWEB)

    Ono, Yushi; Nakagami, Motonori; Hayashi, Haruhisa; Ichikawa, Yoshihiro [Chubu Electric Power Co. Inc., Nagoya (Japan)

    2002-11-01

    At the Hamaoka Nuclear Power Station Unit-1 (540 MWe of electric output; BWR-4 type) of the Chubu Electric Power Co., Ltd., an incident of pipe rupture of residual heat removal system on steam condenser system occurred on November, 2001. This incident gave no effects on outer parts of the station, because safety system apparatuses in the station worked adequately from a standpoint of accidental phenomenon. On the other hand, on its forming processes, as it is no similar case at the nuclear power stations in and out of Japan, to securely carry out countermeasures for preventing a recurrence of the incidence, its cause was striven to elucidate thoroughly. This paper was introduced about contents and results on site surveys, and surveys such as tests, analysis, and so on performed for about a half year after the incident, for preventing a recurrence of similar incidents. (G.K.)

  19. Optimal Selection of Floating Platform for Tidal Current Power Station

    Directory of Open Access Journals (Sweden)

    Fengmei Jing

    2013-06-01

    Full Text Available With continuous development of marine engineering, more and more new structures are used in the exploring of tidal current energy. Three are there different kinds of support structures for tidal current power station, which are sea-bed mounted/gravity based system, pile mounted system and floating moored platform. Comparison with them, the floating mooring system is suit for deep water and the application of which will be widely. In this study, catamaran and semi-submersible as floating platform of tidal current power station are studied. And they are compared with its economic, efficiency of turbine and stability of station. It is found that the catamaran is optimal choice. Based on basic ship theory and using software MOSES, the stability of Catamaran tidal current power station is also calculated. The research of this study is significant and it will be as the reference for the future study.

  20. Space Station Freedom power - A reliability, availability, and maintainability assessment of the proposed Space Station Freedom electric power system

    Science.gov (United States)

    Turnquist, S. R.; Twombly, M.; Hoffman, D.

    1989-01-01

    A preliminary reliability, availability, and maintainability (RAM) analysis of the proposed Space Station Freedom electric power system (EPS) was performed using the unit reliability, availability, and maintainability (UNIRAM) analysis methodology. Orbital replacement units (ORUs) having the most significant impact on EPS availability measures were identified. Also, the sensitivity of the EPS to variations in ORU RAM data was evaluated for each ORU. Estimates were made of average EPS power output levels and availability of power to the core area of the space station. The results of assessments of the availability of EPS power and power to load distribution points in the space stations are given. Some highlights of continuing studies being performed to understand EPS availability considerations are presented.

  1. Power Factor Improvement for Pumping Stations using Capacitor Banks

    Science.gov (United States)

    Mohamad, M. M.; Abd El-gawad, Amal F.; Ramadan, H. S.

    2016-10-01

    One of the fundamental problems affects the performance of pumping stations is its relative high operational cost. As three-phase induction motors are the main prime mover of pumping stations and considered the most widely used electrical motors due to their reliability, ease of maintenance. However, its major problem is the low power factor which results in high electric energy consumption. Energy will be saved when power factor is improved. The main objective of this paper is studying the power factor improvement in El sadaa Pumping Station because of its low operating efficiency which goes from 20 % to 25 %and calculating penalty, ponus and savings in each cases. The correction is achieved by the addition of capacitor banks in parallel with the connected motor circuits and can be applied to the starter, applied at the switchboard or the distribution panel. A model of this station is created using MatlabTM Simulink. Then the determination of induction motor parameters is performed. The station model is discussed. From the simulation results, the power factor enhancement of the pumping station is highlighted.

  2. Physics Experiments at the Agesta Power Station

    Energy Technology Data Exchange (ETDEWEB)

    Apelqvist, G. [State Power Board, Stockholm (Sweden); Bliselius, P. Aa.; Blomberg, P.E.; Jonsson, E.; Aakerhielm, F. [AB Atomenergi, Nykoeping (Sweden)

    1966-09-15

    Part A. Dynamic measurements have been performed at the Aagesta reactor at power levels from 0.3 to 65 MW(th). The purposes of the experiments have been both to develop experimental methods and equipment for the dynamic studies and to measure the dynamic characteristics of the reactor in order to check the dynamic model. The experiments have been performed with four different perturbation functions: trapezoidal and step functions and two types of periodic multifrequency signals. Perturbations were introduced in the reactivity and in the load. The recordings were made of the responses of nuclear power, coolant inlet and outlet temperature and control rod position. The results are presented as step responses and transfer functions (Bode diagrams). Inmost cases the relative accuracy is {+-} 0.5 dB in amplitude and {+-} 5 deg in phase. The results from the experiments in general show rather good agreement with the results obtained from a dynamic model, which successively has been improved. Experience on reactor noise analysis based on measurements in the Agesta power reactor is discussed. It is shown that the noise measurements have given complementary dynamic information of the reactor. Part B. Static measurements of the physics parameters in the Agesta reactor are carried out to confirm theoretical methods for reactor calculations and to form a good basis for safe operation of the reactor. The reactivity worth of groups of control rods are determined with different methods and compared with calculations with the three-dimensional code HETERO. The excess reactivity as a function of burn up is obtained from the control rod positions. The temperature coefficient of the moderator is measured by lowering the moderator temperature at constant power and observing the change in control rod insertion. As burn up increases the experiments are repeated in order to follow the changes in the coefficient. The xenon poisoning effects are measured by changing the power level and

  3. GHG PSD Permit: Cheyenne Light, Fuel & Power / Black Hills Power, Inc. – Cheyenne Prairie Generating Station

    Science.gov (United States)

    This page contains the final PSD permit for the Cheyenne Light, Fuel & Power / Black Hills Power, Inc. Cheyenne Prairie Generating Station, located in Laramie, Wyoming, and operated by Black Hills Service Company.

  4. Milliwatt radioisotope power supply for the PASCAL Mars surface stations

    Science.gov (United States)

    Allen, Daniel T.; Murbach, Marcus S.

    2001-02-01

    A milliwatt power supply is being developed based on the 1 watt Light-Weight Radioisotope Heater Unit (RHU), which has already been used to provide heating alone on numerous spacecraft. In the past year the power supply has been integrated into the design of the proposed PASCAL Mars Network Mission, which is intended to place 24 surface climate monitoring stations on Mars. The PASCAL Mars mission calls for the individual surface stations to be transported together in one spacecraft on a trajectory direct from launch to orbit around Mars. From orbit around Mars each surface station will be deployed on a SCRAMP (slotted compression ramp) probe and, after aerodynamic and parachute deceleration, land at a preselected location on the planet. During descent sounding data and still images will be accumulated, and, once on the surface, the station will take measurements of pressure, temperature and overhead atmospheric optical depth for a period of 10 Mars years (18.8 Earth years). Power for periodic data acquisition and transmission to orbital then to Earth relay will come from a bank of ultracapacitors which will be continuously recharged by the radioisotope power supply. This electronic system has been designed and a breadboard built. In the ultimate design the electronics will be arrayed on the exterior surface of the radioisotope power supply in order to take advantage of the reject heat. This assembly in turn is packaged within the SCRAMP, and that assembly comprises the surface station. An electrically heated but otherwise prototypical power supply was operated in combination with the surface station breadboard system, which included the ultracapacitors. Other issues addressed in this work have been the capability of the generator to withstand the mechanical shock of the landing on Mars and the effectiveness of the generator's multi-foil vacuum thermal insulation. .

  5. A Series Dissertation on Tianwan Nuclear Power Station--Summary of Tianwan Nuclear Power Station Project

    Institute of Scientific and Technical Information of China (English)

    Li Qiankun

    2006-01-01

    This is a summary in relation to the construction and operation of Tianwan Nuclear Power Station (the Project) at Lianyungang, Jiangsu Province, the People' s Republic of China. The breakdown specialty topic shall been given in times to come. In this report, the author attempted to give some general description of the Project, including the Project site' s general layout and geographical conditions. A description of its exposure to the elements is also provided, supported by some data made available to us. The key component parts of the Project are described, namely, the nuclear island which includes the reactor, steam generator and so on; the conventional island and the balance of plant. Wherever possible, the improvements to the reactor design over the operating V320 are highlighted, which result in the V428 reactor model. The supplier and contractor for the major equipment such as the reactor and the turbine is the Russian company, namely Atomstroyexport (ASE). There are third country suppliers who provide other equipment. For instance, Siemens supplies the full digital I&C system and Framatome ANP supplies the emergency diesel generators; the metal-clad switchgear cabinet by ABB of Australia; the main steam isolation valve unit by CCI AG of Switzerland. All these foreign suppliers are well known globally. Their experience and quality of the equipment supplied by them are well recognized by the people in the respective fields. As for the civil work and erection work, the most experienced and trustworthy local contractors have been selected. These contractors have proven their competence in similar contract work before. For the testing of the equipment, stringent and proper procedures which meet international standards are adopted. Finally, the author wished on this report could provide the world a safety and advanced Nuclear Project building in China.

  6. A Renewably Powered Hydrogen Generation and Fueling Station Community Project

    Science.gov (United States)

    Lyons, Valerie J.; Sekura, Linda S.; Prokopius, Paul; Theirl, Susan

    2009-01-01

    The proposed project goal is to encourage the use of renewable energy and clean fuel technologies for transportation and other applications while generating economic development. This can be done by creating an incubator for collaborators, and creating a manufacturing hub for the energy economy of the future by training both white- and blue-collar workers for the new energy economy. Hydrogen electrolyzer fueling stations could be mass-produced, shipped and installed in collaboration with renewable energy power stations, or installed connected to the grid with renewable power added later.

  7. Environmental research at Berkeley

    CERN Multimedia

    1973-01-01

    The information concerning the Energy and Environment Programme at the Lawrence Berkeley Laboratory is based on a talk given at CERN by A.M. Sessler, one of the initiators of the Programme. (Dr. Sessler has been appointed Director of the Lawrence Berkeley Laboratory, in succession to Prof. E. M. McMillan, from 1 November.) Many of the topics mentioned merit an extended story in themselves but the purpose of this article is simply to give a sketch of what is happening.

  8. Solar Power Station Output Inverter Control Design

    Directory of Open Access Journals (Sweden)

    J. Bauer

    2011-04-01

    Full Text Available The photovoltaic applications spreads in these days fast, therefore they also undergo great development. Because the amount of the energy obtained from the panel depends on the surrounding conditions, as intensity of the sun exposure or the temperature of the solar array, the converter must be connected to the panel output. The Solar system equipped with inverter can supply small loads like notebooks, mobile chargers etc. in the places where the supplying network is not present. Or the system can be used as a generator and it shall deliver energy to the supply network. Each type of the application has different requirements on the converter and its control algorithm. But for all of them the one thing is common – the maximal efficiency. The paper focuses on design and simulation of the low power inverter that acts as output part of the whole converter. In the paper the design of the control algorithm of the inverter for both types of inverter application – for islanding mode and for operation on the supply grid – is discussed. Attention is also paid to the design of the output filter that should reduce negative side effects of the converter on the supply network.

  9. Bioremediation for coal-fired power stations using macroalgae.

    Science.gov (United States)

    Roberts, David A; Paul, Nicholas A; Bird, Michael I; de Nys, Rocky

    2015-04-15

    Macroalgae are a productive resource that can be cultured in metal-contaminated waste water for bioremediation but there have been no demonstrations of this biotechnology integrated with industry. Coal-fired power production is a water-limited industry that requires novel approaches to waste water treatment and recycling. In this study, a freshwater macroalga (genus Oedogonium) was cultivated in contaminated ash water amended with flue gas (containing 20% CO₂) at an Australian coal-fired power station. The continuous process of macroalgal growth and intracellular metal sequestration reduced the concentrations of all metals in the treated ash water. Predictive modelling shows that the power station could feasibly achieve zero discharge of most regulated metals (Al, As, Cd, Cr, Cu, Ni, and Zn) in waste water by using the ash water dam for bioremediation with algal cultivation ponds rather than storage of ash water. Slow pyrolysis of the cultivated algae immobilised the accumulated metals in a recalcitrant C-rich biochar. While the algal biochar had higher total metal concentrations than the algae feedstock, the biochar had very low concentrations of leachable metals and therefore has potential for use as an ameliorant for low-fertility soils. This study demonstrates a bioremediation technology at a large scale for a water-limited industry that could be implemented at new or existing power stations, or during the decommissioning of older power stations.

  10. Efficiency of Modern Power Plants of Thermal Power Stations

    Directory of Open Access Journals (Sweden)

    B. V. Yakovlev

    2007-01-01

    Full Text Available The paper considers efficiency and prospects in development of different types of fossil-fuel power plants – gas turbine, steam turbine and combined (gas and steam cycles.The paper provides information on plant selection, fuel consumption, specific output cost. It describes main advantages of various power plants.

  11. FUEL CELL OPERATION ON LANDFILL GAS AT PENROSE POWER STATION

    Science.gov (United States)

    This demonstration test successfully demonstrated operation of a commercial phosphoric acid fuel cell (FC) on landfill gas (LG) at the Penrose Power Station in Sun Valley, CA. Demonstration output included operation up to 137 kW; 37.1% efficiency at 120 kW; exceptionally low sec...

  12. Thermal control system for Space Station Freedom photovoltaic power module

    Science.gov (United States)

    Hacha, Thomas H.; Howard, Laura

    1994-01-01

    The electric power for Space Station Freedom (SSF) is generated by the solar arrays of the photovoltaic power modules (PVM's) and conditioned, controlled, and distributed by a power management and distribution system. The PVM's are located outboard of the alpha gimbals of SSF. A single-phase thermal control system is being developed to provide thermal control of PVM electrical equipment and energy storage batteries. This system uses ammonia as the coolant and a direct-flow deployable radiator. The description and development status of the PVM thermal control system is presented.

  13. Tampa Electric Company Polk Power Station IGCC project: Project status

    Energy Technology Data Exchange (ETDEWEB)

    McDaniel, J.E.; Carlson, M.R.; Hurd, R.; Pless, D.E.; Grant, M.D. [Tampa Electric Co., FL (United States)

    1997-12-31

    The Tampa Electric Company Polk Power Station is a nominal 250 MW (net) Integrated Gasification Combined Cycle (IGCC) power plant located to the southeast of Tampa, Florida in Polk County, Florida. This project is being partially funded under the Department of Energy`s Clean Coal Technology Program pursuant to a Round II award. The Polk Power Station uses oxygen-blown, entrained-flow IGCC technology licensed from Texaco Development Corporation to demonstrate significant reductions of SO{sub 2} and NO{sub x} emissions when compared to existing and future conventional coal-fired power plants. In addition, this project demonstrates the technical feasibility of commercial scale IGCC and Hot Gas Clean Up (HGCU) technology. The Polk Power Station achieved ``first fire`` of the gasification system on schedule in mid-July, 1996. Since that time, significant advances have occurred in the operation of the entire IGCC train. This paper addresses the operating experiences which occurred in the start-up and shakedown phase of the plant. Also, with the plant being declared in commercial operation as of September 30, 1996, the paper discusses the challenges encountered in the early phases of commercial operation. Finally, the future plans for improving the reliability and efficiency of the Unit in the first quarter of 1997 and beyond, as well as plans for future alternate fuel test burns, are detailed. The presentation features an up-to-the-minute update on actual performance parameters achieved by the Polk Power Station. These parameters include overall Unit capacity, heat rate, and availability. In addition, the current status of the start-up activities for the HGCU portion of the plant is discussed.

  14. El idealismo de Berkeley

    Directory of Open Access Journals (Sweden)

    David Sobrevilla

    1995-12-01

    Full Text Available En esta conferencia se examina en qué consiste el idealismo de Berkeley. Para ello se sigue el mismo camino propuesto por G .J. Warnock: se indaga contra qué se opone Berkeley, el materialismo, y cómo lo entiende, y por qué está en contra del mismo. A continuación se reexamina el idealismo berkeleyano, y en la consideración final se juzgan sus virtudes y defectos: algunas de las críticas fundadas que se le han formulado y la visión de la ciencia que se desprende de los escritos de Berkeley. A este respecto se pone en conexión las ideas del autor con algunos planteamientos del último Husserl y con una interpretación de Popper sobre la sorprendente modernidad de algunas de las ideas berkeleyanas sobre la ciencia.

  15. Efficient ways for setting up the operation of nuclear power stations in power systems in the base load mode

    Science.gov (United States)

    Aminov, R. Z.; Shkret, A. F.; Burdenkova, E. Yu.; Garievskii, M. V.

    2011-05-01

    The results obtained from studies of efficient ways and methods for organizing the operation of developing nuclear power stations in the base load mode are presented. We also show comparative efficiency of different scenarios for unloading condensing thermal power stations, cogeneration stations, combined-cycle power plants, nuclear power stations, and using off-peak electric energy for electricity-intensive loads: pumped-hydroelectric storage, electric-powered heat supply, and electrolysis of water for producing hydrogen and oxygen.

  16. TEDS Base Station Power Amplifier using Low-Noise Envelope Tracking Power Supply

    DEFF Research Database (Denmark)

    Høyerby, Mikkel Christian Wendelboe; Andersen, Michael A. E.

    2009-01-01

    This paper demonstrates a highly linear and efficient TETRA enhanced data service (TEDS) base-station RF power amplifier (RFPA). Based on the well-known combination of an envelope tracking (ET) power supply and a linear class-A/B RFPA, adequate adjacent channel power ratio (ACPR) and wideband noise...

  17. Floating tidal power station. Schwimmkoerper-Gezeiten-Kraftwerk

    Energy Technology Data Exchange (ETDEWEB)

    Muenzner, H.J.

    1987-03-19

    This is a floating tidal power station, characterized by the fact that water stores are lifted by the tide by float lifts in the form of docks; on the flood tide they are supported mechanically at the height reached by support members or hydraulically, until after several tides a favourable and economically justifiable height for the technical efficiency of water turbines is reached by the first water store. The stored water is then released through water turbines to obtain energy. This emptied water store is then lowered to the initial position with the support members with the aid of emptied float lifts built like ship's lifting equipment (which only require a slight movement of a weight for lifting and lowering). The filling and lifting is then repeated. During this regeneration, the energy is obtained from the next water store. A whole floating tidal power station consists of as many water stores as are required for uninterrupted continuous operation.

  18. FLAME MONITORING IN POWER STATION BOILERS USING IMAGE PROCESSING

    OpenAIRE

    K Sujatha; VENMATHI, M.; N. Pappa

    2012-01-01

    Combustion quality in power station boilers plays an important role in minimizing the flue gas emissions. In the present work various intelligent schemes to infer the flue gas emissions by monitoring the flame colour at the furnace of the boiler are proposed here. Flame image monitoring involves capturing the flame video over a period of time with the measurement of various parameters like Carbon dioxide (CO2), excess oxygen (O2), Nitrogen dioxide (NOx), Sulphur dioxide (SOx) and Carbon monox...

  19. Legionella control in power station cooling towers using oxidising biocides

    Energy Technology Data Exchange (ETDEWEB)

    Sailer, Christian; Rawlinson, Julia; Killeen, Paul [Ecolab PTY LTD, Ascot, WA (Australia)

    2009-02-15

    Power stations have used oxidising biocides such as chlorine or bromine for many years to control microbial growth in their cooling towers. In this paper Ecolab trademark looks at the direct effect halogen concentration has on Legionella populations in order to determine the most effective halogenation rate required to ensure that the site key performance indicator (KPI) of < 100 colony-forming units (cfu) per mL can be maintained. (orig.)

  20. 47 CFR 74.707 - Low power TV and TV translator station protection.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Low power TV and TV translator station... SERVICES Low Power TV, TV Translator, and TV Booster Stations § 74.707 Low power TV and TV translator station protection. (a)(1) A low power TV or TV translator will be protected from interference from...

  1. Station normal : the power of the Stave River

    Energy Technology Data Exchange (ETDEWEB)

    Stanley, M.; Wilson, H. [BC Hydro, Vancouver, BC (Canada)

    2001-07-01

    This book documented the history of power development along the Stave River and Stave Falls in British Columbia. The book was compiled from memories of employees and retired employees who helped to build the power station along the Stave River. The book provided details of the technical achievements accomplished during the construction of the hydro-electric project, and described the roles and functions of BC Hydro workers at the plant. The book also chronicled the project's growth over time, and discussed its impact on communities in the region. The book included over 100 photographs, as well as a chronology. refs., tabs., figs.

  2. Application of ORC power station to increase electric power of gas compression ignition engine

    Directory of Open Access Journals (Sweden)

    Mocarski Szymon

    2017-01-01

    Full Text Available The paper presents the calculation results of efficiency of the subcritical low temperature ORC power station powered by waste heat resulting from the process of cooling a stationary compression ignition engine. The source of heat to supply the ORC power station is the heat in a form of water jet cooling the engine at a temperature of 92°C, and the exhaust gas stream at a temperature of 420°C. The study considers three variants of systems with the ORC power stations with different ways of using heat source. The first variant assumes using just engine cooling water to power the ORC station. In the second variant the ORC system is powered solely by a heat flux from the combustion gases by means of an intermediary medium - thermal oil, while the third variant provides the simultaneous management of both heat fluxes to heat the water stream as a source of power supply to the ORC station. The calculations were made for the eight working media belonging both to groups of so-called dry media (R218, R1234yf, R227ea and wet media (R32, R161, R152a, R134a, R22.

  3. Renewable Power for the Swedish Antarctic Station Wasa

    Energy Technology Data Exchange (ETDEWEB)

    Henryson, Mattias; Svensson, Martin [Royal Inst. of Technology, Stockholm (Sweden). Dept. of Energy Technology

    2004-07-01

    As the debate on fossil fuel usage in Antarctica has been more and more highlighted, the participating countries, bound by the Antarctic treaty, have encouraged changes in their power systems. Some of the stations or research stations in Antarctica are very large, constituting smaller towns with all conceivable service, and hence very energy consuming. Focus is put on partly or completely replacing fossil fuelled energy with renewable energy such as wind and solar power, supported by either batteries or fuel cells. Today there are a number of both successful and unsuccessful installations of renewable energy systems in Antarctica. Implementing a power system in remote areas where continuous access is limited comprises great technical challenges and Antarctica fulfils by all means every difficulty involved. The objective of this thesis is to propose ways of meeting power and energy demands for the Swedish Antarctic Research Program (SWEDARP) under the strict environmental legislations by as far as possible utilising the free renewable energy resources. A new power system is aimed at supplying 1 kW of electric power for continuous monitoring and collection of research data. The station is manned for three months, which implies a need of an autonomous system with high reliability. The following was based on a technical viability and economical feasibility study. Results are based upon analyses and computer simulations (HOMER) on how each fundamental system component is expected to work in the harsh climate conditions found at the station Wasa in Antarctica. It was found that wind power has the greatest potential as primary energy source in Antarctica. Supported by appropriate batteries, a reliable and in many ways feasible system can be obtained. Nevertheless, for the chosen techniques to endure the harsh climate conditions, sufficient modifications and developments of each component are needed. Based on the analyses the survey results in a proposal for a final system

  4. Station power supply by residual steam of Fugen

    Energy Technology Data Exchange (ETDEWEB)

    Kamiya, Y.; Kato, H.; Hattori, S. (Power Reactor and Nuclear Fuel Development Corp., Tokyo (Japan))

    1981-09-01

    In the advanced thermal reactor ''Fugen'', when the sudden decrease of load more than 40% occurs due to the failure of power system, the turbine regulating valve is rapidly shut, and the reactor is brought to scrum. However, the operation of turbo-generators is continued with the residual steam in the reactor, and the power for inside the station is supplied for 30 sec by the limiting timer, then the power-generating plant is automatically stopped. The reasons why such design was adopted are to reduce manual operation at the time of emergency, to continue water supply for cooling the reactor and to maintain the water level in the steam drum, and to reduce steam release from the safety valve and the turbine bypass valve. The output-load unbalance relay prevents the everspeed of the turbo-generator when load decreased suddenly, but when the failure of power system is such that recovers automatically in course of time, it does not work. The calculation for estimating the dynamic characteristics at the time of the sole operation within the station is carried out by the analysis code FATRAC. The input conditions for the calculation and the results are reported. Also the dynamic characteristics were actually tested to confirm the set value of the limiting timer and the safe working of turbine and generator trips. The estimated and tested results were almost in agreement.

  5. Floating type ocean wave power station equipped with hydroelectric unit

    Science.gov (United States)

    Okamoto, Shun; Kanemoto, Toshiaki; Umekage, Toshihiko

    2013-10-01

    The authors have invented the unique ocean wave power station, which is composed of the floating type platform with a pair of the floats lining up at the interval of one wave pitch and the counter-rotating type wave power unit, its runners are submerged in the seawater at the middle position of the platform. Such profiles make the flow velocity at the runner is twice faster than that of the traditional fixed/caisson type OWC, on the ideal flow conditions. Besides, the runners counter-rotate the inner and the outer armatures of the peculiar generator, respectively, and the relative rotational speed is also twice faster than the speed of the single runner/armature. Such characteristics make the runner diameter large, namely the output higher, as requested, because the torque of the power unit never act on the floating type platform. At the preliminary reseach, this paper verifies to get the power using a Wells type single runner installed in the model station. The runner takes the output which is affected by the oscillating amplitude of the platform, the rotational speed and the inertia force of the runner, etc.

  6. Optimized Envelope Tracking Power Supply for Tetra2 Base Station RF Power Amplifier

    DEFF Research Database (Denmark)

    Høyerby, Mikkel Christian Wendelboe; Andersen, Michael Andreas E.

    2008-01-01

    An ultra-fast tracking power supply (UFTPS) for envelope tracking in a 50kHz 64-QAM Tetra2 base station power amplification system is demonstrated. A simple method for optimizing the step response of the PID+PD sliding-mode control system is presented and demonstrated, along with a PLL-based scheme...

  7. GT power generation stations in noise sensitive areas

    Energy Technology Data Exchange (ETDEWEB)

    Gambino, V.; Richarz, W. [Aercoustics Engineering Ltd., Toronto, ON (Canada)

    2009-07-01

    Noise impact must be quantified during the initial planning phase of a power plant because it may play a part in potential land acquisitions and system configuration. Noise control measures are required at gas turbine power generating stations located in noise sensitive areas. This study used graphs to illustrate that assigning noise control priorities may be complicated. Noise ranking with respect to the contribution of sound power was plotted against the ranking with respect to the contribution of sound pressure levels. Noise impact estimates based on a simplistic source model tend to over-predict the actual sound levels. More detailed emission models are needed during the initial planning phase to help assess the cost of any noise controls. The methodology described in this paper was developed to help the developer during the planning phases to determine the relative contribution of various components to the overall sound and to mitigate excessive noise. 4 tabs., 7 figs.

  8. Berkeley, California: Solar in Action (Brochure)

    Energy Technology Data Exchange (ETDEWEB)

    2011-10-01

    This brochure provides an overview of the challenges and successes of Berkeley, CA, a 2007 Solar America City awardee, on the path toward becoming a solar-powered community. Accomplishments, case studies, key lessons learned, and local resource information are given.

  9. Operating Experience at the Aagesta Nuclear Power Station

    Energy Technology Data Exchange (ETDEWEB)

    Sandstroem, S. (ed.)

    1966-09-15

    Sweden's first nuclear power reactor Agesta, achieved criticality on July 17, 1963. Full power (65 MW{sub t}) was attained on March 20, 1964. Aagesta is a heavy water cooled and moderated pressure vessel reactor used for production of electricity as well as for district heating. The design, assembly and construction etc, of the reactor was described in detail in a staff report by AB Atomenergi, 'The Aagesta Nuclear Power Station' edited by B McHugh, which was published in September, 1964. In the book experiences from the commissioning and the first operation of the reactor were reported as well as findings from the extensive reactor physics studies made during this period. The report now presented is written by members of the operating team at Aagesta since its start. It reflects in general the experiences up to the end of 1965. The Aagesta Log, however, covers the period up to the normal summer stop 1966. The reactor has hitherto produced 506,000 MWh power of which 48,700 MWh have been electric power. In July 1965 the responsibility for the reactor operation was taken over by the Swedish State Power Board from AB Atomenergi, which company had started the reactor and operated it until the summer break 1965.

  10. Performance of International Space Station Alpha electric power systems

    Energy Technology Data Exchange (ETDEWEB)

    Hill, R.; Lu, C.Y.; Padhye, V.; Hajela, G.; Hague, L. [Rockwell International, Canoga Park, CA (United States). Rocketdyne Division

    1995-12-31

    The International Space Station Alpha (ISSA) will be an Earth-orbiting laboratory in space. It will house experimental payloads, distribute resource utilities, and support human habitation for conducting research and science experiments in a microgravity environment. Electrical power is a major utility to support successful achievement of the mission goal. The ISSA United States On-Orbit Segment (USOS) Electric Power System (EPS) power generation capability will vary with orbital parameters, natural and induced environment, and hardware aging/replacement throughout the ISSA life. Power capability will be further restricted by various assembly configurations during ISSA buildup, by various flight attitudes, by shadowing on the solar arrays, by EPS operational constraints, such as pointing accuracy, battery charging, as well as operating voltage setpoints, and by ISSA operational constraints either to avoid long-term solar array shadowing from the adjacent solar array or to accommodate ISSA maneuver during proximity operations with other space vehicles, mating, and departing. Design of the ISSA USOS EPS takes into consideration the various equipment degradation modes, operation constraints, and orbital conditions to make it compatible with the environments and to meet power, lifetime, and performance requirements.

  11. Biofouling surveillance at a power station with seawater intake gates

    Energy Technology Data Exchange (ETDEWEB)

    Sasikumar, N.; Nair, K.V.K. [Indira Gandhi Centre for Atomic Research, Kalpakkam (India)

    1997-04-01

    Biofouling monitoring of the seawater intake gates of Madras` atomic power station (MAPS) in India was carried out for a period of two years. The settlement and growth rates, composition, and biomass of fouling between the intake filter gates and the test panels exposed in the coastal waters were compared and the results showed significant differences. The major foulant of the tunnel -green mussel, Perna viridis, and barnacle, Megabalanus tintinnabulum - though generally absent on test panels, was present on the intake gates. Relatively-high growth rates with heavy biomass were found at the intake gates as compared to the test panel. The study suggests that the intake gates can be used for a reliable fouling prediction in coastal power plants. (Author).

  12. High pressure axial flow fans for modern coal power stations

    Energy Technology Data Exchange (ETDEWEB)

    Cyrus, Vaclav [AHT Energetika s.r.o., Praha (Czech Republic); Koci, Petr [ZVVZ Milevsko a.s. (Czech Republic)

    2008-07-01

    Brown coal fired power stations, located in Northern Bohemia, have mostly older boiler blocks with an output of 110 and 200 MWe. Flue gases are cleaned by the desulphurization plants installed between 1993 and 1997. Usually, each boiler block has two air fans and one to three flue gas fans. Flue gas fans operate in severe conditions; fan blades should be resistant to the flue gases containing sulphur and acid drops with the operating temperature at 170 C to 190 C. Additionally, flue gas also often contains ash particles. Currently, some boiler blocks are gradually being refurbished. New blocks with an electrical power output of 600 to 700 MWe are at the design stage. Submitted paper shows our design study of one stage axial flow fan for the new blocks. Results from the new aerodynamic research of the axial flow stages were used in the fan design. (orig.)

  13. Flyash disposal problems at thermal power stations - an experimental study

    Energy Technology Data Exchange (ETDEWEB)

    Reddy, E.S.; Peter, E.C.N.; Sastri, K.R.; Kura, B. [JNTU College of Engineering, Hyderabad (India). Dept. of Civil Engineering

    1999-06-10

    Disposal of fly ash at coal-fired power stations is carried out in the form of ash slurry by mixing the ash with water. The ash slurry is stored in an ash pond. The water in the slurry is gradually drained out, through decanting wells, earthen embankments and over spillways, leaving the ash to deposit in the pond. The design of decanting wells presently being used in power stations, such as Vijayawada in India allows a considerable amount of flyash to flow out with water, leading to the contamination of soil and the water courses. Further, the failure of earthen bunds of ash ponds, which results in a major damage to the environment, is mainly due to ineffective functioning of filters in the bunds. This paper presents the details of an experimental investigation carried out to study the role of geotextiles in improving the performance of decanting wells and earthen bunds. Two series of experiments were carried out. In the first series two model decanting wells were tested with geotextile lining. In the second series, a number of model earthen bunds were tested with and without geotextiles. Economics of providing geotextiles in earthen bunds is studied. The results indicated that, the use of geotextiles is economical and effective in improving the performance of decanting wells and the earthen bunds of an ash pond. 15 refs., 10 figs., 6 tabs.

  14. Developing the concept of maintenance and repairs in projects of power units for new-generation nuclear power stations

    Science.gov (United States)

    Gurinovich, V. D.; Yanchenko, Yu. A.

    2012-05-01

    Results from conceptual elaboration of individual requirements for the system of maintenance and repairs that must be implemented in the projects of new-generation nuclear power stations are presented taking as an example the power unit project for a nuclear power station equipped with a standard optimized VVER reactor with enhanced information support (the so-called VVER TOI reactor). Implementation of these concepts will help to achieve competitiveness of such nuclear power stations in the domestic and international markets.

  15. Berkeley Nuclear Data Cloud

    Energy Technology Data Exchange (ETDEWEB)

    2017-04-27

    The software was developed to serve and curate arbitrarily large datasets comprising data acquired from various mobile platforms. The software is contained in a number of server and client libraries. The former manage the ingestion, indexing, querying, and serving of the data. The latter libraries are distributed for Linux, Mac OSX, and Windows and enable users to interact with data downloaded from the service either in the form of an HDF5 file or streamed in a BSON data chunk. Using the Berkeley Data Cloud, researchers from varying fields can collaborate, compare results and curate both their raw data and the derived products of their analysis.

  16. 75 FR 63766 - Digital Low Power Television, Television Translator, and Television Booster Stations and Digital...

    Science.gov (United States)

    2010-10-18

    ... COMMISSION 47 CFR Parts 73 and 74 Digital Low Power Television, Television Translator, and Television Booster Stations and Digital Class A Television Stations AGENCY: Federal Communications Commission. ACTION... that need to be resolved to complete the low power television station digital transition....

  17. SOARCA Peach Bottom Atomic Power Station Long-Term Station Blackout Uncertainty Analysis: Knowledge Advancement.

    Energy Technology Data Exchange (ETDEWEB)

    Gauntt, Randall O.; Mattie, Patrick D.; Bixler, Nathan E.; Ross, Kyle W.; Cardoni, Jeffrey N; Kalinich, Donald A.; Osborn, Douglas.; Sallaberry, Cedric Jean-Marie; Ghosh, S. Tina

    2014-02-01

    This paper describes the knowledge advancements from the uncertainty analysis for the State-of- the-Art Reactor Consequence Analyses (SOARCA) unmitigated long-term station blackout accident scenario at the Peach Bottom Atomic Power Station. This work assessed key MELCOR and MELCOR Accident Consequence Code System, Version 2 (MACCS2) modeling uncertainties in an integrated fashion to quantify the relative importance of each uncertain input on potential accident progression, radiological releases, and off-site consequences. This quantitative uncertainty analysis provides measures of the effects on consequences, of each of the selected uncertain parameters both individually and in interaction with other parameters. The results measure the model response (e.g., variance in the output) to uncertainty in the selected input. Investigation into the important uncertain parameters in turn yields insights into important phenomena for accident progression and off-site consequences. This uncertainty analysis confirmed the known importance of some parameters, such as failure rate of the Safety Relief Valve in accident progression modeling and the dry deposition velocity in off-site consequence modeling. The analysis also revealed some new insights, such as dependent effect of cesium chemical form for different accident progressions. (auth)

  18. Energy Sharing Framework for Microgrid-Powered Cellular Base Stations

    KAUST Repository

    Farooq, Muhammad Junaid

    2017-02-07

    Cellular base stations (BSs) are increasingly becoming equipped with renewable energy generators to reduce operational expenditures and carbon footprint of wireless communications. Moreover, advancements in the traditional electricity grid allow two-way power flow and metering that enable the integration of distributed renewable energy generators at BS sites into a microgrid. In this paper, we develop an optimized energy management framework for microgrid-connected cellular BSs that are equipped with renewable energy generators and finite battery storage to minimize energy cost. The BSs share excess renewable energy with others to reduce the dependency on the conventional electricity grid. Three cases are investigated where the renewable energy generation is unknown, perfectly known, and partially known ahead of time. For the partially known case where only the statistics of renewable energy generation are available, stochastic programming is used to achieve a conservative solution. Results show the time varying energy management behaviour of the BSs and the effect of energy sharing between them.

  19. Retrieval of Intermediate Level Waste at Trawsfyndd Nuclear Power Station

    Energy Technology Data Exchange (ETDEWEB)

    Wall, S.; Shaw, I.

    2002-02-25

    In 1996 RWE NUKEM Limited were awarded two contracts by BNFL Magnox Generation as part of the decommissioning programme for the Trawsfynydd power station. From the normal operations of the two Magnox reactors, intermediate level waste (ILW) had accumulated on site, this was Miscellaneous Activated Components (MAC) and Fuel Element Debris (FED). The objective of these projects is retrieval of the waste from storage vaults, monitoring, packaging and immobilization in a form suitable for on site storage in the medium term and eventual disposal to a waste repository. The projects involve the design, supply, commissioning and operation of equipment to retrieve, pack and immobilize the waste, this includes recovery from vaults in both reactor and pond locations and final decommissioning and removal of plant from site after completion of waste recovery.

  20. Aquatic impacts from operation of three midwestern nuclear power stations: Fort Calhoun station, Unit No. 1 environmental appraisal report

    Energy Technology Data Exchange (ETDEWEB)

    El-Shamy, F.

    1981-10-01

    Fort Calhoun Station, Unit 1, is located on the west bank of the Missouri River in Washington County, Nebraska. The station, a nuclear powered generating facility producing 475 net megawatts, utilizes a once-through cooling design. The station influences the aquatic biota of the Missouri River vicinity in several ways. The heated discharges of the station were found to have no significant impacts to fish, periphyton, and benthic macroinvertebrates. Minor effects to phytoplankton were noted in warm summer months at the point of discharge. An estimated 227,900,000 fish larvae were entrained annually from the river's ichthyoplankton community, the majority identified as freshwater drum. Fort Calhoun Station impinged an estimated 170,882 fish annually, large numbers of which were freshwater drum and gizzard shad with potential losses to channel and flathead catfish. The station was shown to have little impact on the zooplankton community.

  1. Small geothermic heat and power station with power plants on organic fluid

    Energy Technology Data Exchange (ETDEWEB)

    Nowak, W.; Wos, M. [Szczecin Univ. of Tech. (Poland). Chair of Heat Engineering

    2006-07-01

    The results of the calculations of heat-flow heats and power stations were introduced in the work geothermic with one circulation, with two circulations and with three circulations. They are reinforced network water heated up in the geothermic heat exchanger to temperatures 100 C and stream. In this solution the temperature of water force to the geothermic hest exchanger changes and amount out suitably 39,35 C (one circulation), 49,83 C (two circulations), 58,91 C (three circulations). He results that the solution of heat and power station is the most profitable variant with three circulations from the analysis of the received results of calculations. He keeps the highest power of the circulation C.R. from three considered variants. (orig.)

  2. Power transmission cable development for the Space Station Freedom electrical power system

    Science.gov (United States)

    Schmitz, Gregory V.; Biess, John J.

    1989-01-01

    Power transmission cable is presently being evaluated under a NASA Lewis Research Center advanced development contract for application in the Space Station Freedom (SSF) electrical power system (EPS). Evaluation testing has been performed by TRW and NASA Lewis Research Center. The results of this development contract are presented. The primary cable design goals are to provide (1) a low characteristic inductance to minimize line voltage drop at 20 kHz, (2) electromagnetic compatibility control of the 20-kHz ac power current, (3) a physical configuration that minimizes ac resistance and (4) release of trapped air for corona-free operation.

  3. Radicals in Berkeley?

    Science.gov (United States)

    Linn, Stuart

    2015-04-03

    In a previous autobiographical sketch for DNA Repair (Linn, S. (2012) Life in the serendipitous lane: excitement and gratification in studying DNA repair. DNA Repair 11, 595-605), I wrote about my involvement in research on mechanisms of DNA repair. In this Reflections, I look back at how I became interested in free radical chemistry and biology and outline some of our bizarre (at the time) observations. Of course, these studies could never have succeeded without the exceptional aid of my mentors: my teachers; the undergraduate and graduate students, postdoctoral fellows, and senior lab visitors in my laboratory; and my faculty and staff colleagues here at Berkeley. I am so indebted to each and every one of these individuals for their efforts to overcome my ignorance and set me on the straight and narrow path to success in research. I regret that I cannot mention and thank each of these mentors individually.

  4. Carbon burnout of pulverised coal in power station furnaces

    Energy Technology Data Exchange (ETDEWEB)

    R.I. Backreedy; L.M. Fletcher; J.M. Jones; L. Ma; M. Pourkashanian; A. Williams; K. Johnson; D.J. Waldron; P. Stephenson [University of Leeds, Leeds (United Kingdom)

    2003-07-01

    The degree of carbon burnout in pulverised fuel fired power stations is important because it is linked with power plant efficiency and coal ash suitability for construction purposes. The use of computational methods to calculate carbon burnout in such systems has been aided by the increasing availability of fast computers and improvements in computational methodologies. Despite recent advances in fluid flow, coal devolatilisation and coal combustion models, the use of CFD methods for detailed design purposes or for the selection of commercial coals is still limited. In parallel, industrial engineering codes, which combine simplified thermal models with advanced coal combustion models, are still undergoing development since they provide economic advantages over detailed CFD analysis. Although the major coal combustion processes are well established, an understanding regarding the role of coal macerals and the influence of ash on the combustion process is still lacking. A successful coal model must be able to handle all the complexities of combustion, from the details of the burner geometry through to the formation of unburnt carbon as well as NOx. The development of such a model is described here.

  5. Integrated Power and Attitude Control Systems for Space Station

    Science.gov (United States)

    Oglevie, R. E.; Eisenhaure, D. B.

    1985-01-01

    Integrated Power and Attitude Control Systems (IPACS) studies performed over a decade ago established the feasibility of simultaneously storing electrical energy in wheels and utilizing the resulting momentum for spacecraft attitude control. It was shown that such a system possessed many advantages over other contemporary energy storage and attitude control systems in many applications. More recent technology advances in composite rotors, magnetic bearings, and power control electronics have triggered new optimism regarding the feasibility and merits of such a system. The paper presents the results of a recent study whose focus was to define an advanced IPACS and to evaluate its merits for the Space Station application. A system and component design concept is developed to establish the system performance capability. A system level trade study, including life-cycle costing, is performed to define the merits of the system relative to two other candidate systems. It is concluded that an advanced IPACS concept is not only feasible, but offers substantial savings in mass, and life-cycle cost.

  6. International Space Station power module thermal control system hydraulic performance

    Energy Technology Data Exchange (ETDEWEB)

    Goldberg, V. [Boeing North American, Inc., Canoga Park, CA (United States). Rocketdyne Div.

    1997-12-31

    The International Space Station (ISS) uses four photovoltaic power modules (PVMs) to provide electric power for the US On-Orbit Segment. The PVMs consist of photovoltaic arrays (PVAs), orbit replaceable units (ORUs), photovoltaic radiators (PVRs), and a thermal control system (TCS). The PVM TCS function is to maintain selected PVM components within their specified operating ranges. The TCS consists of the pump flow control subassembly (PFCS), piping system, including serpentine tubing for individual component heat exchangers, headers/manifolds, fluid disconnect couplings (FQDCs), and radiator (PVR). This paper describes the major design requirements for the TCS and the results of the system hydraulic performance predictions in regard to these requirements and system component sizing. The system performance assessments were conducted using the PVM TCS fluid network hydraulic model developed for predicting system/component pressure losses and flow distribution. Hardy-Cross method of iteration was used to model the fluid network configuration. Assessments of the system hydraulic performance were conducted based on an evaluation of uncertainties associated with the manufacturing and design tolerances. Based on results of the analysis, it was concluded that all design requirements regarding system performance could be met. The hydraulic performance range, enveloping possible system operating parameter variations was determined.

  7. Gas-turbine expander power generating systems for internal needs of compressor stations of gas-main pipelines

    Science.gov (United States)

    Shimanov, A. A.; Biryuk, V. V.; Sheludko, L. P.; Shabanov, K. Yu.

    2017-08-01

    In the framework of this paper, there have been analyzed power station building methods to construct a power station for utilities for gas-main pipelines compressor stations. The application efficiency of turbo expanders in them to expand the power gas of compressor stations' gas compressor units has been shown. New schemes for gas-turbine expander power generating systems have been proposed.

  8. DC-DC power converter research for Orbiter/Station power exchange

    Science.gov (United States)

    Ehsani, M.

    1993-01-01

    This project was to produce innovative DC-DC power converter concepts which are appropriate for the power exchange between the Orbiter and the Space Station Freedom (SSF). The new converters must interface three regulated power buses on SSF, which are at different voltages, with three fuel cell power buses on the Orbiter which can be at different voltages and should be tracked independently. Power exchange is to be bi-directional between the SSF and the Orbiter. The new converters must satisfy the above operational requirements with better weight, volume, efficiency, and reliability than is available from the present conventional technology. Two families of zero current DC-DC converters were developed and successfully adapted to this application. Most of the converters developed are new and are presented.

  9. Determination of Technological Electric Power Consumption for Its Transportation while Using Block-Stations

    Directory of Open Access Journals (Sweden)

    V. V. Pavlovets

    2010-01-01

    Full Text Available The paper proposes a method for calculation of the technological electric power consumption for its transportation in the elements of power network while using block-stations under conditions of differently-directed electric power transfer.The calculation of technological electric power consumption for its transportation can be applied while supplying several consumers with one element of power network simultaneously with block-station operation. 

  10. Space Station Freedom electric power system photovoltaic power module integrated launch package

    Science.gov (United States)

    Nathanson, Theodore H.; Clemens, Donald D.; Spatz, Raymond R.; Kirch, Luke A.

    1990-01-01

    The launch of the Space Station Freedom solar power module requires a weight efficient structure that will include large components within the limited load capacity of the Space Shuttle cargo bay. The design iterations to meet these requirements have evolved from a proposal concept featuring a separate cradle and integrated equipment assembly (IEA), to a package that interfaces directly with the Shuttle. Size, weight, and cost have been reduced as a result.

  11. Measurements and Modelling of Base Station Power Consumption under Real Traffic Loads

    Directory of Open Access Journals (Sweden)

    Goran Petrovic

    2012-03-01

    Full Text Available Base stations represent the main contributor to the energy consumption of a mobile cellular network. Since traffic load in mobile networks significantly varies during a working or weekend day, it is important to quantify the influence of these variations on the base station power consumption. Therefore, this paper investigates changes in the instantaneous power consumption of GSM (Global System for Mobile Communications and UMTS (Universal Mobile Telecommunications System base stations according to their respective traffic load. The real data in terms of the power consumption and traffic load have been obtained from continuous measurements performed on a fully operated base station site. Measurements show the existence of a direct relationship between base station traffic load and power consumption. According to this relationship, we develop a linear power consumption model for base stations of both technologies. This paper also gives an overview of the most important concepts which are being proposed to make cellular networks more energy-efficient.

  12. 75 FR 8153 - Nebraska Public Power District; Cooper Nuclear Station Environmental Assessment and Finding of No...

    Science.gov (United States)

    2010-02-23

    ... COMMISSION Nebraska Public Power District; Cooper Nuclear Station Environmental Assessment and Finding of No... District (NPPD, the licensee), for operation of the Cooper Nuclear Station (CNS), located in Nemaha County... Statement for the Cooper Nuclear Station dated February 1973. Agencies and Persons Consulted In...

  13. C. Judson King of UC Berkeley

    Energy Technology Data Exchange (ETDEWEB)

    Prausnitz, John

    2005-06-01

    In the middle of the UC Berkeley campus, next to the Main Library, South Hall is the last surviving building from the original campus, founded about 135 years ago. A tiny tree-shaded appendix to this venerated classical building houses Berkeley's Center for Studies in Higher Education, directed by C. Judson King, former Provost and Senior Vice President--Academic Affairs of the ten-campus University of California and long-time Professor of Chemical Engineering at Berkeley. Jud came to Berkeley in 1963 as assistant professor of chemical engineering, following receipt of a doctor's degree from MIT and a subsequent short appointment as director of the MIT chemical engineering practice school station at what was then Esso (now Exxon) in New Jersey. His undergraduate degree is from Yale. Starting with his MIT doctoral dissertation on gas absorption, Jud has devoted much of his professional career to separation processes. His teaching and research activities have been primarily concerned with separation of mixtures with emphasis on liquid-liquid extraction and drying. As a consultant to Procter and Gamble, he contributed to the technology of making instant coffee. His life-long activities in hiking and camping stimulated Jud's interest in the manufacture of freeze-dried foods (e.g. turkey meat) to minimize the weight of his hiking back-pack. Jud is internationally known not only for his many research publications but even more, for his acclaimed textbook ''Separation Processses'' (McGraw-Hill, second edition 1980) that is used in standard chemical engineering courses in the US and abroad.

  14. Flyash disposal problems at thermal power stations - an experimental study

    Energy Technology Data Exchange (ETDEWEB)

    Reddy, E.S.; Peter, E.C. Nirmala; Sastri, K. Rama [JNTU Coll. of Engineering, Dept. of Civil Engineering, Hyderabad (India); Kura, Bhaskar [New Orleans Univ., Dept. of Civil and Environmental Engineering, New Orleans, LA (United States)

    1999-07-01

    Disposal of flyash at thermal power stations is carried out in the form of ash slurry by mixing the ash with water. The ash slurry is stored in an ash pond. The water in the slurry is gradually drained out, through decanting wells, earthen embankments and over spillways, leaving the ash to deposit in the pond. It is observed that, the design of decanting wells presently being used allows a considerable amount of flyash to flow out with water, leading to the contamination of soil and the water courses. Further, it is observed that, the failure of earthen bunds of ash ponds, which results in a major damage to the environment, is mainly due to ineffective functioning of filters in the bunds. This paper presents the details of an experimental investigation carried out to study the role of geotextiles in improving the performance of decanting wells and earthen bunds. Two series of experiments were carried out. In the first series two model decanting wells were tested with geotextile lining. In the second series, a number of model earthen bunds were tested with and without geotextiles. Economics of providing geotextiles in earthen bunds is studied. The results indicated that, the use of geotextiles is economical and effective improving the performance of decanting wells and the earthen bunds of an ash pond. (Author)

  15. The Fukushima Nuclear Power Station incident and marine pollution.

    Science.gov (United States)

    Chang, Yen-Chiang; Zhao, Yue

    2012-05-01

    Based on the facts relating to the radioactive wastewater discharged by the Fukushima Nuclear Power Station in Japan, this paper intends to explore the international legal obligations for Japan from three perspectives, namely, the immediate notification, the prevention of transboundary harm and the prevention of dumping. Furthermore, this article defines and compares two types of international legal liabilities, the traditional state responsibility and the responsibility for transboundary harm. Through comparison, the international legal liability of Japan is discussed. After detailed analysis, the conclusion is that Japan should be responsible for the obligation of immediate notification and since Japan unilaterally discharge the wastes without prior specific permits of other contracting countries, it should also be responsible for the violation of prevention of dumping. Since so far, no material injury has emerged and there would appear to be no culpability as regards the prevention of transboundary harm. Finally, this paper stresses the necessity to develop a worldwide agreement concerning the liability for transboundary harm and to establish an institutional framework for the enforcement of a state's obligations, and also the great significance of international cooperation between nations and organisations in relation to marine environmental protection. Copyright © 2012 Elsevier Ltd. All rights reserved.

  16. Insulating brick from fly ash of thermal power stations

    Energy Technology Data Exchange (ETDEWEB)

    Mukherjee, S.N.; Majumdar, A.; Majumdar, S.K.

    1986-04-01

    Disposal of fly ash, a major byproduct of thermal power stations burning high ash pulverized fuel, has posed a serious problem of storage space required on one hand and the cost involved on the other. Fly ash possesses pozzolanic property. R and D work on utilization of fly ash in the form of sand-lime brick or cellular concrete has been already done. Other avenues of utilization are cement and concrete industry. All these are based on pozzolanic property of fly ash which decreases with the increase of unburnt carbon content in the same. The overall present consumption of fly ash is barely 5-7 per cent of the total production. A process has been developed to utilize fly ash with comparatively higher amount of carbonaceous matter in particular, to make insulating/semi-insulating bricks of standard size through use of other normal ingredients like clay (a plastic material), sulphite lye, molasses, etc. as binder along with some propertion of saw dust. The bricks made so far have been tested for their normal properties and these conform to a product of semi-insulating type. 21 refs., 2 tabs.

  17. Optimization and Feasibility Analysis of Satellite Earth Station Power System Using Homer

    Directory of Open Access Journals (Sweden)

    Hassen T. Dorrah

    2012-06-01

    Full Text Available Satellite earth stations which located in remote areas are one of many applications powered by the renewable energy sources. Ground system consists of ground station and control centers working together to support the spacecraft and the data user. Earth station consists of major subsystems, transmitter, receiver, antenna, tracking equipment, terrestrial interface equipment and power supply. Power subsystem is an important part that required for supplying the earth station with electrical power to continue communicating with its remote sensing satellite. This paper deals with simulation and optimal sizing of earth station power system using HOMER software. A combination of two energy sources (solar, and wind to provide a continuous electric power production is used to determine the optimum system operation. Three system configurations are compared with respect to the total net present cost (NPC and levelized cost of energy (COE. Also, economical study will be analyzed for energy demand and sensitivity analysis will be performed.

  18. Optimization and Feasibility Analysis of Satellite Earth Station Power System Using Homer

    Directory of Open Access Journals (Sweden)

    Hassen T. Dorrah

    2012-06-01

    Full Text Available Satellite earth stations which located in remote areas are one of many applications powered by the renewable energy sources. Ground system consists of ground station and control centers working together to support the spacecraft and the data user. Earth station consists of major subsystems, transmitter, receiver, antenna, tracking equipment, terrestrial interface equipment and power supply. Power subsystem is an important part that required for supplying the earth station with electrical power to continue communicating with its remote sensing satellite. This paper deals with simulation and optimal sizing of earth station power system using HOMER software. A combination of two energy sources (solar, and wind to provide a continuous electric power production is used to determine the optimum system operation. Three system configurations are compared with respect to the total net present cost (NPC and levelized cost of energy (COE. Also, economical study will be analyzed for energy demand and sensitivity analysis will be performed.

  19. Power system monitoring and source control of the Space Station Freedom DC power system testbed

    Science.gov (United States)

    Kimnach, Greg L.; Baez, Anastacio N.

    1992-01-01

    Unlike a terrestrial electric utility which can purchase power from a neighboring utility, the Space Station Freedom (SSF) has strictly limited energy resources; as a result, source control, system monitoring, system protection, and load management are essential to the safe and efficient operation of the SSF Electric Power System (EPS). These functions are being evaluated in the DC Power Management and Distribution (PMAD) Testbed which NASA LeRC has developed at the Power System Facility (PSF) located in Cleveland, Ohio. The testbed is an ideal platform to develop, integrate, and verify power system monitoring and control algorithms. State Estimation (SE) is a monitoring tool used extensively in terrestrial electric utilities to ensure safe power system operation. It uses redundant system information to calculate the actual state of the EPS, to isolate faulty sensors, to determine source operating points, to verify faults detected by subsidiary controllers, and to identify high impedance faults. Source control and monitoring safeguard the power generation and storage subsystems and ensure that the power system operates within safe limits while satisfying user demands with minimal interruptions. System monitoring functions, in coordination with hardware implemented schemes, provide for a complete fault protection system. The objective of this paper is to overview the development and integration of the state estimator and the source control algorithms.

  20. Study of wet blasting of components in nuclear power stations

    Energy Technology Data Exchange (ETDEWEB)

    Hall, J

    1999-12-01

    This report looks at the method of wet blasting radioactive components in nuclear power stations. The wet blaster uses pearl shaped glass beads with the dimensions of 150-250 {mu}m mixed with water as blasting media. The improved design, providing outer operator's positions with proper radiation protection and more efficient blasting equipment has resulted in a lesser dose taken by the operators. The main reason to decontaminate components in nuclear power plants is to enable service on these components. On components like valves, pump shafts, pipes etc. oxides form and bind radiation. These components are normally situated at some distance from the reactor core and will mainly suffer from radiation from so called activation products. When a component is to be decontaminated it can be decontaminated to a radioactive level where it will be declassified. This report has found levels ranging from 150-1000 Bq/kg allowing declassification of radioactive materials.This difference is found between different countries and different organisations. The report also looks at the levels of waste generated using wet blasting. This is done by tracking the contamination to determine where it collects. It is either collected in the water treatment plant or collected in the blasting media. At Barsebaeck the waste levels, from de-contaminating nearly 800 components in one year, results in a waste volume of about 0,250 m{sup 3}. This waste consists of low and medium level waste and will cost about 3 600 EURO to store. The conclusions of the report are that wet blasting is an indispensable way to treat contaminated components in modern nuclear power plants. The wet blasting equipment can be improved by using a robot enabling the operators to remotely treat components from the outer operator's positions. There they will benefit from better radiation protection thus further reduce their taken dose. The wet blasting equipment could also be used to better control the levels of

  1. Novel Radio on Fiber Access Eliminating External Electric Power Supply at Base Station

    Institute of Scientific and Technical Information of China (English)

    Tetsuya; Miki; Katsuyasu; Kawano; Nobuo; Nakajima; Naoto; Kishi; Masaru; Miyamoto; Tetsu; Aoki

    2003-01-01

    A novel Radio On Fiber(ROF) access is proposed and demonstrated which enables the pico-cell Base Station (BS) for high-speed wireless communications to eliminate external electric power supply facilities. We demonstrated 2.4-GHz band radio signal transmission through the BS without external electric power supply. The electrical power used for BS circuit is feeded by optical power over optical fiber from central station.

  2. 76 FR 11680 - Digital Low Power Television, Television Translator, and Television Booster Stations and Digital...

    Science.gov (United States)

    2011-03-03

    ... COMMISSION 47 CFR Parts 73 and 74 Digital Low Power Television, Television Translator, and Television Booster Stations and Digital Class A Television Stations AGENCY: Federal Communications Commission. ACTION: Final... 73 and 74 of the Commission's Rules to Establish Rules for Digital Low Power, Television...

  3. Construction of a nuclear power station in one's locality: attitudes and salience

    NARCIS (Netherlands)

    van der Pligt, J.; Eiser, J.R.; Spears, R.

    1986-01-01

    Examined the attitudes toward the building of a nuclear power station in one's locality by surveying 290 residents (mean age 47.5 yrs) of 3 small rural communities that were listed as possible locations for a new nuclear power station. Results show that a large majority of Ss opposed the building of

  4. 76 FR 72849 - Digital Low Power Television, Television Translator, and Television Booster Stations and To Amend...

    Science.gov (United States)

    2011-11-28

    ... COMMISSION 47 CFR Parts 73 and 74 Digital Low Power Television, Television Translator, and Television Booster... Rules to Establish Rules for Digital Low Power Television, Television Translator, and Television Booster Stations and to Amend Rules for Digital Class A Television Stations, MB Docket No. 03-185; FCC 11-110,...

  5. 78 FR 66385 - Omaha Public Power District Fort Calhoun Station, Unit 1; Exemption

    Science.gov (United States)

    2013-11-05

    ... From the Federal Register Online via the Government Publishing Office NUCLEAR REGULATORY COMMISSION Omaha Public Power District Fort Calhoun Station, Unit 1; Exemption 1.0 Background Omaha Public Power District (OPPD, the licensee) is the holder of Renewed Facility Operating License No. DPR-40, which authorizes operation of Fort Calhoun Station...

  6. 78 FR 37592 - Omaha Public Power District, Fort Calhoun Station, Unit 1; Exemption

    Science.gov (United States)

    2013-06-21

    ... From the Federal Register Online via the Government Publishing Office NUCLEAR REGULATORY COMMISSION Omaha Public Power District, Fort Calhoun Station, Unit 1; Exemption 1.0 Background Omaha Public Power District (OPPD, the licensee) is the holder of Facility Operating License, which authorizes operation of Fort Calhoun Station (FCS), Unit 1....

  7. Using plasma-fuel systems at Eurasian coal-fired thermal power stations

    Science.gov (United States)

    Karpenko, E. I.; Karpenko, Yu. E.; Messerle, V. E.; Ustimenko, A. B.

    2009-06-01

    The development of plasma technology for igniting solid fuels at coal-fired thermal power stations in Russia, Kazakhstan, China, and other Eurasian countries is briefly reviewed. Basic layouts and technical and economic characteristics of plasma-fuel systems installed in different coal-fired boiles are considered together with some results from using these systems at coal-fired thermal power stations.

  8. Using plasma-fuel systems at Eurasian coal-fired thermal power stations

    Energy Technology Data Exchange (ETDEWEB)

    E.I. Karpenko; Y.E. Karpenko; V.E. Messerle; A.B. Ustimenko [RAO Unified Energy Systems of Russia, Gusinoozersk (Russian Federation). Russia Sectional Center for Plasma-Power Technologies

    2009-07-01

    The development of plasma technology for igniting solid fuels at coal-fired thermal power stations in Russia, Kazakhstan, China, and other Eurasian countries is briefly reviewed. Basic layouts and technical and economic characteristics of plasma-fuel systems installed in different coal-fired boiles are considered together with some results from using these systems at coal-fired thermal power stations.

  9. Local opposition to the construction of a nuclear power station: differential salience of impacts

    NARCIS (Netherlands)

    Eiser, J.R.; van der Pligt, J.; Spears, R.

    1988-01-01

    Surveyed attitudes among 290 residents of 3 villages in southwest England toward proposals to build a nuclear power station nearby. Ss were grouped according to being neutral or in favor of a new power station either locally or elsewhere (Group PN), against one locally but neutral or pro elsewhere (

  10. International lunar observatory / power station: from Hawaii to the Moon

    Science.gov (United States)

    Durst, S.

    Astronomy's great advantages from the Moon are well known - stable surface, diffuse atmosphere, long cool nights (14 days), low gravity, far side radio frequency silence. A large variety of astronomical instruments and observations are possible - radio, optical and infrared telescopes and interferometers; interferometry for ultra- violet to sub -millimeter wavelengths and for very long baselines, including Earth- Moon VLBI; X-ray, gamma-ray, cosmic ray and neutrino detection; very low frequency radio observation; and more. Unparalleled advantages of lunar observatories for SETI, as well as for local surveillance, Earth observation, and detection of Earth approaching objects add significant utility to lunar astronomy's superlatives. At least nine major conferences in the USA since 1984 and many elsewhere, as well as ILEWG, IAF, IAA, LEDA and other organizations' astronomy-from-the-Moon research indicate a lunar observatory / power station, robotic at first, will be one of the first mission elements for a permanent lunar base. An international lunar observatory will be a transcending enterprise, highly principled, indispensable, soundly and broadly based, and far- seeing. Via Astra - From Hawaii to the Moon: The astronomy and scie nce communities, national space agencies and aerospace consortia, commercial travel and tourist enterprises and those aspiring to advance humanity's best qualities, such as Aloha, will recognize Hawaii in the 21st century as a new major support area and pan- Pacific port of embarkation to space, the Moon and beyond. Astronomical conditions and facilities on Hawaii's Mauna Kea provide experience for construction and operation of observatories on the Moon. Remote and centrally isolated, with diffuse atmosphere, sub-zero temperature and limited working mobility, the Mauna Kea complex atop the 4,206 meter summit of the largest mountain on the planet hosts the greatest collection of large astronomical telescopes on Earth. Lunar, extraterrestrial

  11. 2009 SCDNR Berkeley County Lidar

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Sanborn Map Company completed the original classification of the multiple return LiDAR of Berkeley County, South Carolina in 2009. In 2013, Dewberry was tasked with...

  12. The Environment Friendly Power Source for Power Supply of Mobile Communication Base Stations

    Science.gov (United States)

    Rudenko, N. V.; Ershov, V. V.; Evstafiev, V. V.

    2017-05-01

    The article describes the technical proposals to improve environmental and resource characteristics of the autonomous power supply systems of mobile communication base stations based on renewable energy sources, while ensuring the required reliability and security of power supply. These include: the replacement of diesel-generator with clean energy source - an electrochemical generator based on hydrogen fuel cells; the use of wind turbines with a vertical axis; use of specialized batteries. Based on the analysis of the know technical solutions, the structural circuit diagram of the hybrid solar-wind-hydrogen power plant and the basic principles of the algorithm of its work were proposed. The implementation of these proposals will improve the environmental and resource characteristics.

  13. Photocatalytic degradation of pollutants from Elcogas IGCC power station effluents.

    Science.gov (United States)

    Durán, A; Monteagudo, J M; San Martín, I; García-Peña, F; Coca, P

    2007-06-01

    The aim of this work is to improve the quality of water effluents coming from Elcogas IGCC power station (Puertollano, Spain) with the purpose of fulfilling future more demanding normative, using heterogeneous photocatalytic oxidation processes (UV/H(2)O(2)/TiO(2) or ZnO). The efficiency of photocatalytic degradation for the different catalysts (TiO(2) and ZnO) was determined from the analysis of the following parameters: cyanides, formates and ammonia content. In a first stage, the influence of two parameters (initial concentration of H(2)O(2) and amount of catalyst) on the degradation kinetics of cyanides and formates was studied based on a factorial experimental design. pH was always kept in a value >9.5 to avoid gaseous HCN formation. The degradation of cyanides and formates was found to follow pseudo-first order kinetics. Experimental kinetic constants were fitted using neural networks (NNs). The mathematical model reproduces experimental data within 90% of confidence and allows the simulation of the process for any value of parameters in the experimental range studied. Moreover, a measure of the saliency of the input variables was made based upon the connection weights of the neural networks, allowing the analysis of the relative relevance of each variable with respect to the others. Results showed that the photocatalytic process was effective, being the degradation rate of cyanides about five times higher when compared to removal of formates. Finally, the effect of lowering pH on the degradation of formates was evaluated after complete cyanides destruction was reached (10 min of reaction). Under the optimum conditions (pH 5.2, [H(2)O(2)]=40 g/l; [TiO(2)]=2g/l), 100% of cyanides and 92% of initial NH(3) concentration are degraded after 10 min, whereas 35 min are needed to degrade 98% of formates.

  14. FLAME MONITORING IN POWER STATION BOILERS USING IMAGE PROCESSING

    Directory of Open Access Journals (Sweden)

    K. Sujatha

    2012-05-01

    Full Text Available Combustion quality in power station boilers plays an important role in minimizing the flue gas emissions. In the present work various intelligent schemes to infer the flue gas emissions by monitoring the flame colour at the furnace of the boiler are proposed here. Flame image monitoring involves capturing the flame video over a period of time with the measurement of various parameters like Carbon dioxide (CO2, excess oxygen (O2, Nitrogen dioxide (NOx, Sulphur dioxide (SOx and Carbon monoxide (CO emissions plus the flame temperature at the core of the fire ball, air/fuel ratio and the combustion quality. Higher the quality of combustion less will be the flue gases at the exhaust. The flame video was captured using an infrared camera. The flame video is then split up into the frames for further analysis. The video splitter is used for progressive extraction of the flame images from the video. The images of the flame are then pre-processed to reduce noise. The conventional classification and clustering techniques include the Euclidean distance classifier (L2 norm classifier. The intelligent classifier includes the Radial Basis Function Network (RBF, Back Propagation Algorithm (BPA and parallel architecture with RBF and BPA (PRBFBPA. The results of the validation are supported with the above mentioned performance measures whose values are in the optimal range. The values of the temperatures, combustion quality, SOx, NOx, CO, CO2 concentrations, air and fuel supplied corresponding to the images were obtained thereby indicating the necessary control action taken to increase or decrease the air supply so as to ensure complete combustion. In this work, by continuously monitoring the flame images, combustion quality was inferred (complete/partial/incomplete combustion and the air/fuel ratio can be automatically varied. Moreover in the existing set-up, measurements like NOx, CO and CO2 are inferred from the samples that are collected periodically or by

  15. Structural Design and Protective Methods for the 100 kW Shoreline Wave Power Station

    Institute of Scientific and Technical Information of China (English)

    游亚戈; 郑永红; 马玉久; 余志; 蒋念东

    2003-01-01

    The structural design and protective methods for the 100 kW shoreline wave power station in China are described in detail. The proper structural type is designed for effective minimization of wave loads and bending stress. Various protective devices are adopted to protect the station in the extreme conditions against excessive power of airflow, excessive torsion of the shaft, over-pressure of the chamber, over-speed of rotation, power failure, and so on. It turns out that the structural design and protective methods for the 100 kW shoreline wave power station are successful.

  16. Influence of Mobile Users' Density Distribution on the CDMA Base Station Power

    Science.gov (United States)

    Lebl, Aleksandar; Mitić, Dragan; Popović, Miroslav; Markov, Žarko; Mileusnić, Mladen; Matić, Vladimir

    2016-12-01

    In this paper we analyze the influence of users' density distribution in one cell of CDMA mobile network (ie adjusted power control on the forward link) on base station emission power. This influence is analyzed for different circles radii around base station within which same emission power is generated for all mobile users, and for different values of propagation loss coefficient. It is proved that emission power in this cell must be increased comparing to the similar cell, which uses complete power control. The power increase is greater when greater number of users are situated near base station, and for greater values of propagation loss coefficient. The results are presented, illustrated by numerical examples and verified by simulation for three users' density distributions: uniform, decreasing and increasing density from the base station to the cell rim. The simulation process, which is based on random traffic process, is presented briefly.

  17. 76 FR 37650 - Safety Zone; 4th of July Festival Berkeley Marina Fireworks Display Berkeley, CA

    Science.gov (United States)

    2011-06-28

    ... SECURITY Coast Guard 33 CFR Part 165 RIN 1625-AA00 Safety Zone; 4th of July Festival Berkeley Marina... Berkeley Pier, Berkeley, CA in support of the 4th of July Festival Berkeley Marina Fireworks Display... used in the fireworks display. Background and Purpose The City of Berkeley Marina will sponsor the 4th...

  18. Dynamic characteristics of power-tower space stations with 15-foot truss bays

    Science.gov (United States)

    Dorsey, J. T.

    1986-01-01

    A power tower space station concept which generates power with photovoltaic arrays and where the truss structure has a bay size of 15 ft is described. Rigid body and flexible body dynamic characteristics are presented for a 75-kW Initial Operating Capability (IOC) and 150-kW and 300-kW growth stations. The transient response of the IOC and 300-kW growth stations to shuttle dock, orbit reboost, and mobile remote manipulator system translation loads are studied. Displacements, accelerations, and bending moments at various locations on the IOC and 300-kW growth stations are presented.

  19. Fuel Characteristics of Thermal Power Station as Index of Its Thermal Efficiency

    Directory of Open Access Journals (Sweden)

    A. E. Piir

    2006-01-01

    Full Text Available It is proposed to calculate values of specific consumptions of conventional fuel for generating heat and electric power in a combined electrical installation (Thermal Power Station on the basis of a thermal and dynamic approach or an exergetic balance of a turbine plant. It is shown that a fuel characteristic of Thermal Power Station is an objective index of a thermal electrical installation

  20. Mission Analysis for LEO Microwave Power-Beaming Station in Orbital Launch of Microwave Lightcraft

    Science.gov (United States)

    Myrabo, L. N.; Dickenson, T.

    2005-01-01

    A detailed mission analysis study has been performed for a 1 km diameter, rechargeable satellite solar power station (SPS) designed to boost 20m diameter, 2400 kg Micr,oWave Lightcraft (MWLC) into low earth orbit (LEO) Positioned in a 476 km daily-repeating oi.bit, the 35 GHz microwave power station is configured like a spinning, thin-film bicycle wheel covered by 30% efficient sola cells on one side and billions of solid state microwave transmitter elements on the other, At the rim of this wheel are two superconducting magnets that can stor,e 2000 G.J of energy from the 320 MW, solar array over a period of several orbits. In preparation for launch, the entire station rotates to coarsely point at the Lightcraft, and then phases up using fine-pointing information sent from a beacon on-board the Lightcraft. Upon demand, the station transmits a 10 gigawatt microwave beam to lift the MWLC from the earth surface into LEO in a flight of several minutes duration. The mission analysis study was comprised of two parts: a) Power station assessment; and b) Analysis of MWLC dynamics during the ascent to orbit including the power-beaming relationships. The power station portion addressed eight critical issues: 1) Drag force vs. station orbital altitude; 2) Solar pressure force on the station; 3) Station orbital lifetime; 4) Feasibility of geo-magnetic re-boost; 5) Beta angle (i..e., sola1 alignment) and power station effective area relationship; 6) Power station percent time in sun vs, mission elapsed time; 7) Station beta angle vs.. charge time; 8) Stresses in station structures.. The launch dynamics portion examined four issues: 1) Ascent mission/trajecto1y profile; 2) MWLC/power-station mission geometry; 3) MWLC thrust angle vs. time; 4) Power station pitch rate during power beaming. Results indicate that approximately 0 58 N of drag force acts upon the station when rotated edge-on to project the minimum frontal area of 5000 sq m. An ion engine or perhaps an electrodynamic

  1. Mathematical modeling of vibrations in turbogenerator sets of Sayano-Shushenskaya Hydroelectric Power Station

    Science.gov (United States)

    Leonov, G. A.; Kuznetsov, N. V.; Solovyeva, E. P.

    2016-02-01

    Oscillations in turbogenerator sets, which consist of a synchronous generator, a hydraulic turbine, and an automatic speed regulator, are investigated. This study was motivated by the emergency that took place at the Sayano-Shushenskaya Hydroelectric Power Station in 2009. During modeling of the parameters of turbogenerator sets of the Sayano-Shushenskaya Hydroelectric Power Station, the ranges corresponding to undesired oscillation regimes were determined. These ranges agree with the results of the full-scale tests of the hydropower units of the Sayano-Shushenskaya Hydroelectric Power Station performed in 1988.

  2. Estimate of arsenic emission amount from the coal power stations in China

    Institute of Scientific and Technical Information of China (English)

    LUO Kunli; ZHANG Xinmin; CHEN Changhe; LU Yilun

    2004-01-01

    To study the amount of arsenic emission from the coal power stations (mainly Permo-Carboniferous coal) in China in different combustion conditions, the arsenic content of the coal, the fly ash and the cinder in high- temperature power stations as well as mid-low temperature power stations have been analyzed. This note provides a rough estimate of the total amount of arsenic emission as well as emission ratio from steam coal combustion in China. The results show that by combustion of 1 t of Permo-Carbonif- erous coal (containing roughly 5 mg/kg arsenic), high-tem- perature power stations emit roughly 0.40 g arsenic into the atmosphere and the arsenic emission rate is about 7.70%; mid-low power stations emit roughly 0.15 g arsenic into the atmosphere and the arsenic emission rate is about 2.97%. A total of 600 million tons coal is burnt annually in China power stations, and the coal comes mainly from Permo- Carboniferous depositing in the North China Plate and northwest China coal mines. Taking the average arsenic content of the coal used at the value of 5 mg/kg, the total annual arsenic emission from steam coal combustion into the atmosphere is about 195.0 t. Most of the arsenic in coal can be released in the process of coal combustion, and the most of the released arsenic can be seized by the fly ash and then both of them are seized by the dust catcher of power station, so the arsenic emission ratio to the atmosphere is declined; in addition, research on the arsenic emission amount and emission rules from the coal power stations in China should go on the coal power stations with the dry-process dust catchers by the experiments results. In the wet process of dust catcher, 20% of the arsenic in the fly ash is dissolved in the water of sedimentation tank in high-temperature power station; in the mid-low temperature power station there are 70% of the arsenic in the fly ash dissolved in the water of sedimentation tank, this is an important source of arsenic pollution in

  3. 47 CFR 73.6019 - Digital Class A TV station protection of low power TV, TV translator, digital low power TV and...

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Digital Class A TV station protection of low power TV, TV translator, digital low power TV and digital TV translator stations. 73.6019 Section 73... BROADCAST SERVICES Class A Television Broadcast Stations § 73.6019 Digital Class A TV station protection...

  4. Harmonic incursion at the point of common coupling due to small grid-connected power stations

    Directory of Open Access Journals (Sweden)

    Majid Mumtaz

    2015-12-01

    Full Text Available The orthodox electric power distribution systems used to be generally radial and direction of flow of power was often from grid towards consumer. Sometimes, the transmission of power generated from newly set small power stations by using transmission network is not feasible due to the transmission losses, service cost on transmission lines and other related issues. That is why, in many cases, small power stations are connected directly to the local distribution network. These small power stations inject active and reactive power to the existing network, badly disturbing the flow of power hence injecting harmonics in the system at the point of common coupling (PCC. This harmonic injection at PCC due to a direct grid-connection of small power stations to the existing large electric power systems is identified. Also, the impact of harmonic incursion by these small generation units is analysed using a straightforward and an effortless method. This simulation based method uses power system components simplified to basic inductive and capacitive elements and can be very helpful for a fast assessment of harmonic incursion at PCC if extended to the practical large inter-connected electric power systems.

  5. 77 FR 52765 - Dominion Nuclear Connecticut, Inc. Millstone Power Station, Unit 3; Exemption

    Science.gov (United States)

    2012-08-30

    ... Millstone Power Station Unit 1, a permanently defueled boiling water reactor nuclear unit, and Millstone...-water nuclear power reactors,'' requires that each power reactor meet the acceptance criteria for ECCS... Reactions at High Temperatures, III. Experimental and Theoretical Studies of the Zirconium-Water...

  6. 75 FR 52997 - Nebraska Public Power District; Cooper Nuclear Station; Exemption

    Science.gov (United States)

    2010-08-30

    ... From the Federal Register Online via the Government Publishing Office NUCLEAR REGULATORY COMMISSION Nebraska Public Power District; Cooper Nuclear Station; Exemption 1.0 Background Nebraska Public... authorizes operation of the Cooper Nuclear Station (CNS). The license provides, among other things, that...

  7. 75 FR 47856 - Nebraska Public Power District: Cooper Nuclear Station; Notice of Availability of the Final...

    Science.gov (United States)

    2010-08-09

    ... From the Federal Register Online via the Government Publishing Office NUCLEAR REGULATORY COMMISSION Nebraska Public Power District: Cooper Nuclear Station; Notice of Availability of the Final... operation for the Cooper Nuclear Station (CNS). CNS is located near Brownville, Nebraska, on the...

  8. 75 FR 10517 - Nebraska Public Power District, Cooper Nuclear Station; Exemption

    Science.gov (United States)

    2010-03-08

    ... From the Federal Register Online via the Government Publishing Office NUCLEAR REGULATORY COMMISSION Nebraska Public Power District, Cooper Nuclear Station; Exemption 1.0 Background Nebraska Public... authorizes operation of the Cooper Nuclear Station (CNS). The license provides, among other things, that...

  9. 75 FR 76055 - Nebraska Public Power District Cooper Nuclear Station; Notice of Issuance of Renewed Facility...

    Science.gov (United States)

    2010-12-07

    ... From the Federal Register Online via the Government Publishing Office NUCLEAR REGULATORY COMMISSION Docket No. 50-298; NRC-2008-0617] Nebraska Public Power District Cooper Nuclear Station; Notice of... operator of the Cooper Nuclear Station (CNS). Renewed facility operating license No. DPR-46...

  10. Inmaterialismo y realismo en Berkeley

    Directory of Open Access Journals (Sweden)

    Antoni Defez

    2016-01-01

    Full Text Available En este trabajo se analizan los argumentos de Berkeley a favor del inmaterialismo. Especial atención se dedica al argumento a priori que subyace en el lema esse est percipi, y sobre todo a la manera en que Berkeley entiende el concepto de existencia y el valor metafísico que otorga a su significación. Asimismo, se explica también cómo este inmaterialismo es un espiritualismo o realismo teológico puesto al servicio de causas apologéticas.

  11. Techno-economic assessments of oxy-fuel technology for South African coal-fired power stations

    CSIR Research Space (South Africa)

    Oboirien, BO

    2014-03-01

    Full Text Available at the technical and economic viability of oxy-fuel technology for CO(sub2) capture for South African coal-fired power stations. This study presents a techno-economic analysis for six coal fired power stations in South Africa. Each of these power stations has a...

  12. 75 FR 16517 - Dominion Nuclear Connecticut, Inc.; Millstone Power Station, Unit Nos 1, 2, and 3; Exemption

    Science.gov (United States)

    2010-04-01

    ... alarm station requirements by September 30, 2010, and certain uninterruptible power supply requirements... certain uninterruptible power requirements and September 30, 2010, for certain alarm station requirements... COMMISSION Dominion Nuclear Connecticut, Inc.; Millstone Power Station, Unit Nos 1, 2, and 3; Exemption...

  13. Electric Power Plants and Generation Stations, KernRiver, Published in 2007, Millard County.

    Data.gov (United States)

    NSGIC GIS Inventory (aka Ramona) — This Electric Power Plants and Generation Stations dataset, was produced all or in part from Other information as of 2007. It is described as 'KernRiver'. Data by...

  14. Development of an HTS hydroelectric power generator for the hirschaid power station

    Science.gov (United States)

    Fair, Ruben; Lewis, Clive; Eugene, Joseph; Ingles, Martin

    2010-06-01

    This paper describes the development and manufacture of a 1.7MW, 5.25kV, 28pole, 214rpm hydroelectric power generator consisting of superconducting HTS field coils and a conventional stator. The generator is to be installed at a hydro power station in Hirschaid, Germany and is intended to be a technology demonstrator for the practical application of superconducting technology for sustainable and renewable power generation. The generator is intended to replace and uprate an existing conventional generator and will be connected directly to the German grid. The HTS field winding uses Bi-2223 tape conductor cooled to about 30K using high pressure helium gas which is transferred from static cryocoolers to the rotor via a bespoke rotating coupling. The coils are insulated with multi-layer insulation and positioned over laminated iron rotor poles which are at room temperature. The rotor is enclosed within a vacuum chamber and the complete assembly rotates at 214rpm. The challenges have been significant but have allowed Converteam to develop key technology building blocks which can be applied to future HTS related projects. The design challenges, electromagnetic, mechanical and thermal tests and results are presented and discussed together with applied solutions.

  15. Development of an HTS hydroelectric power generator for the hirschaid power station

    Energy Technology Data Exchange (ETDEWEB)

    Fair, Ruben; Lewis, Clive; Eugene, Joseph; Ingles, Martin, E-mail: ruben.fair@converteam.co [Advanced Technology Group, Converteam, Rugby, CV21 1BD (United Kingdom)

    2010-06-01

    This paper describes the development and manufacture of a 1.7MW, 5.25kV, 28pole, 214rpm hydroelectric power generator consisting of superconducting HTS field coils and a conventional stator. The generator is to be installed at a hydro power station in Hirschaid, Germany and is intended to be a technology demonstrator for the practical application of superconducting technology for sustainable and renewable power generation. The generator is intended to replace and uprate an existing conventional generator and will be connected directly to the German grid. The HTS field winding uses Bi-2223 tape conductor cooled to about 30K using high pressure helium gas which is transferred from static cryocoolers to the rotor via a bespoke rotating coupling. The coils are insulated with multi-layer insulation and positioned over laminated iron rotor poles which are at room temperature. The rotor is enclosed within a vacuum chamber and the complete assembly rotates at 214rpm. The challenges have been significant but have allowed Converteam to develop key technology building blocks which can be applied to future HTS related projects. The design challenges, electromagnetic, mechanical and thermal tests and results are presented and discussed together with applied solutions.

  16. Differential permeability behaviour of P9 and T22 power station Steels

    OpenAIRE

    Karimian, N a; Wilson, JWa; Peyton, AJa; Yin, W a; Liu, J. B.; Davis, CLb

    2014-01-01

    Analysis of the electromagnetic (EM) properties of power station steels, measured using a non-contact magnetic sensor, is of significance as such properties are indicative of the microstructure of the material and can be potentially exploited for non-destructive testing. In this paper, we present EM measurements of cylindrical power station steel samples (P9 and T22 grades) with different microstructures: normalised and tempered (representative of the initial condition), as normalised and aft...

  17. Assesment of Carbon Credits for Power Generation Systems at GSM Base Station Site

    OpenAIRE

    Ani, Vincent Anayochukwu; Ani, Emmanuel Onyeka

    2016-01-01

    Electricity production is often a source of CO2 emissions, for instance when fossil fuel is combusted in power plants. Therefore the root cause of pollution coming from telecommunication industry is the source of energy (diesel genset) the network operators used in running their Base station sites. Energy consumption of using diesel to power base station by telecom networks is a contributor to global greenhouse gas (GHG) emissions. This paper presents the comparative carbon credits of hybrid ...

  18. Approach to reducing the effect of bone-coal power station on radiation environment

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    The effect of two bone-coal power stations (6 MWe) on environment wasinvestigated within the scope of the dose contribution caused by various radionucildes in different ways. It is found that the best measures to reduce the effect of bone-coal power station on radiation environment include to select a fine boiler system and a comprehensive utilization of the bone-coal cinder (BCC), soot and ash in the catchers.

  19. Approach to reducing the effect of bone—coal power station on radiation environment

    Institute of Scientific and Technical Information of China (English)

    NIShi-Ying; GUPei-Long; 等

    2002-01-01

    The effect of two bone-coal power stations(6MWe) on environment was investigated within the scope of the dose contribution caused by various radionucildes in different ways.It is found that the best measures to reduce the effect of bone-coal power station on radiation environment include to select a fine boiler system and a comprehensive utilization of the bone-coal cinder(BCC),soot and ash in the catchers.

  20. The Berkeley Serendip Project

    Science.gov (United States)

    Bowyer, S.; Werthimer, D.; Tarter, J.; Buhse, R.

    1986-01-01

    An automated system was designed to perform a real time search for narrow band radio signals in the spectra of sources in a regularly scheduled, non-SETI astronomical observing program. The system will compute the power spectrum using a 65,536 channel fast Fourier transform processor with a real time bandwidth of 128 KHz and 2 Hz per channel resolution. After search for peaks in a 100 KHz portion of the IF band of the radio telescope, the system will move to the next 100 KHz portion using a programmable frequency synthesizer. When the whole IF band is scanned, the process will start again. Unidentified peaks in the power spectra are candidates for further study and their celestial coordinates will be recorded along with the time and power, IF and RF frequency, and bandwidth of the peak. Most of the hardware was developed and the machine software is in the process of being finalized. A number of means for identifying and rejecting power spectra peaks which have a high likelihood of being nonuseful are being investigated.

  1. Berkeley Proton Linear Accelerator

    Science.gov (United States)

    Alvarez, L. W.; Bradner, H.; Franck, J.; Gordon, H.; Gow, J. D.; Marshall, L. C.; Oppenheimer, F. F.; Panofsky, W. K. H.; Richman, C.; Woodyard, J. R.

    1953-10-13

    A linear accelerator, which increases the energy of protons from a 4 Mev Van de Graaff injector, to a final energy of 31.5 Mev, has been constructed. The accelerator consists of a cavity 40 feet long and 39 inches in diameter, excited at resonance in a longitudinal electric mode with a radio-frequency power of about 2.2 x 10{sup 6} watts peak at 202.5 mc. Acceleration is made possible by the introduction of 46 axial "drift tubes" into the cavity, which is designed such that the particles traverse the distance between the centers of successive tubes in one cycle of the r.f. power. The protons are longitudinally stable as in the synchrotron, and are stabilized transversely by the action of converging fields produced by focusing grids. The electrical cavity is constructed like an inverted airplane fuselage and is supported in a vacuum tank. Power is supplied by 9 high powered oscillators fed from a pulse generator of the artificial transmission line type.

  2. Design of a photovoltaic central power station: flat-plate array

    Energy Technology Data Exchange (ETDEWEB)

    1984-02-01

    A design for a photovoltaic central power station using fixed flat-panel arrays has been developed. The 100 MW plant is assumed to be located adjacent to the Saguaro Power Station of Arizona Public Service. The design assumes high-efficiency photovoltaic modules using dendritic web cells. The modules are arranged in 5 MW subfields, each with its own power conditioning unit. The photovoltaic output is connected to the existing 115 kV utility switchyard. The site specific design allows detailed cost estimates for engineering, site preparation, and installation. Collector and power conditioning costs have been treated parametrically.

  3. Using MapReduce to Improve the Power Generation of the International Space Station

    Science.gov (United States)

    Marchetto, William R., II

    The International Space Station (ISS) spends approximately 98% of its time in orbits that experience Earth eclipse. Since the station's solar arrays produce no power when in Earth's shadow, the total power generated decreases substantially, lowering the power budget available to experimental payloads. Therefore, increasing the power output during these eclipsed orbits would be of great benefit to the space station's scientific endeavors. The ISS's current solar array configuration tracks the Sun throughout each orbit, keeping each of its 16 solar panels perpendicular to the Sun at all times. While this is the optimal orientation for solar panels with unobstructed views of the Sun, the space station's solar arrays experience shadowing from the spacecraft's structure as well as from the other solar panels. Deviating from the Sun-tracking scheme at strategic points in certain orbits can provide an increase in power output. The goal of this research was to provide a programmatic solution that increases the power generation capabilities of the ISS in orbits experiencing Earth-eclipse without requiring any physical modifications to the space station's structure. To achieve this goal, a simulator was developed to model the ISS-Earth-Sun environment and calculate the power output of the station's solar arrays based on each panel's orientation and shadowing. Many combinations of array configurations were analyzed, taking into account the physical constraints of the gimbals responsible for rotating the solar panels. The power output of the ISS was improved for the subset of Earth-eclipsed orbits that experience a high degree of shadowing from the station's structure, resulting in an average energy increase of 1.08 kWh per orbit. The power gains were achieved by quickly rotating the solar arrays through the points in each orbit that experienced the highest degree of shadowing.

  4. Molecular Foundry, Berkeley, California (Revised)

    Energy Technology Data Exchange (ETDEWEB)

    Carlisle, N.

    2008-03-01

    This case study provides information on the Molecular Foundry, which incorporates Labs21 principles in its design and construction. The design includes many of the strategies researched at Lawrence Berkeley Laboratory for energy efficient cleanroom and data centers. The result is an energy efficient high-performing sustainable laboratory.

  5. Application of Hybrid Optimization-Expert System for Optimal Power Management on Board Space Power Station

    Science.gov (United States)

    Momoh, James; Chattopadhyay, Deb; Basheer, Omar Ali AL

    1996-01-01

    The space power system has two sources of energy: photo-voltaic blankets and batteries. The optimal power management problem on-board has two broad operations: off-line power scheduling to determine the load allocation schedule of the next several hours based on the forecast of load and solar power availability. The nature of this study puts less emphasis on speed requirement for computation and more importance on the optimality of the solution. The second category problem, on-line power rescheduling, is needed in the event of occurrence of a contingency to optimally reschedule the loads to minimize the 'unused' or 'wasted' energy while keeping the priority on certain type of load and minimum disturbance of the original optimal schedule determined in the first-stage off-line study. The computational performance of the on-line 'rescheduler' is an important criterion and plays a critical role in the selection of the appropriate tool. The Howard University Center for Energy Systems and Control has developed a hybrid optimization-expert systems based power management program. The pre-scheduler has been developed using a non-linear multi-objective optimization technique called the Outer Approximation method and implemented using the General Algebraic Modeling System (GAMS). The optimization model has the capability of dealing with multiple conflicting objectives viz. maximizing energy utilization, minimizing the variation of load over a day, etc. and incorporates several complex interaction between the loads in a space system. The rescheduling is performed using an expert system developed in PROLOG which utilizes a rule-base for reallocation of the loads in an emergency condition viz. shortage of power due to solar array failure, increase of base load, addition of new activity, repetition of old activity etc. Both the modules handle decision making on battery charging and discharging and allocation of loads over a time-horizon of a day divided into intervals of 10

  6. Mercury emissions from South Africa’s coal-fired power stations

    Directory of Open Access Journals (Sweden)

    Belinda L. Garnham

    2016-12-01

    Full Text Available Mercury is a persistent and toxic substance that can be bio-accumulated in the food chain. Natural and anthropogenic sources contribute to the mercury emitted in the atmosphere. Eskom’s coal-fired power stations in South Africa contributed just under 93% of the total electricity produced in 2015 (Eskom 2016. Trace amounts of mercury can be found in coal, mostly combined with sulphur, and can be released into the atmosphere upon combustion. Coal-fired electricity generation plants are the highest contributors to mercury emissions in South Africa. A major factor affecting the amount of mercury emitted into the atmosphere is the type and efficiency of emission abatement equipment at a power station. Eskom employs particulate emission control technology at all its coal-fired power stations, and new power stations will also have sulphur dioxide abatement technology. A co-beneficial reduction of mercury emissions exists as a result of emission control technology. The amount of mercury emitted from each of Eskom’s coal-fired power stations is calculated, based on the amount of coal burnt and the mercury content in the coal. Emission Reduction Factors (ERF’s from two sources are taken into consideration to reflect the co-benefit received from the emission control technologies at the stations. Between 17 and 23 tons of mercury is calculated to have been emitted from Eskom’s coal-fired power stations in 2015. On completion of Eskom’s emission reduction plan, which includes fabric filter plant retrofits at two and a half stations and a flue gas desulphurisation retrofit at one power station, total mercury emissions from the fleet will potentially be reduced by 6-13% by 2026 relative to the baseline. Mercury emission reduction is perhaps currently not the most pressing air quality problem in South Africa. While the focus should then be on reducing emissions of other pollutants which have a greater impact on human health, mercury emission reduction

  7. On Variable Reverse Power Flow-Part I: Active-Reactive Optimal Power Flow with Reactive Power of Wind Stations

    Directory of Open Access Journals (Sweden)

    Aouss Gabash

    2016-02-01

    Full Text Available It has recently been shown that using battery storage systems (BSSs to provide reactive power provision in a medium-voltage (MV active distribution network (ADN with embedded wind stations (WSs can lead to a huge amount of reverse power to an upstream transmission network (TN. However, unity power factors (PFs of WSs were assumed in those studies to analyze the potential of BSSs. Therefore, in this paper (Part-I, we aim to further explore the pure reactive power potential of WSs (i.e., without BSSs by investigating the issue of variable reverse power flow under different limits on PFs in an electricity market model. The main contributions of this work are summarized as follows: (1 Introducing the reactive power capability of WSs in the optimization model of the active-reactive optimal power flow (A-R-OPF and highlighting the benefits/impacts under different limits on PFs. (2 Investigating the impacts of different agreements for variable reverse power flow on the operation of an ADN under different demand scenarios. (3 Derivation of the function of reactive energy losses in the grid with an equivalent-π circuit and comparing its value with active energy losses. (4 Balancing the energy curtailment of wind generation, active-reactive energy losses in the grid and active-reactive energy import-export by a meter-based method. In Part-II, the potential of the developed model is studied through analyzing an electricity market model and a 41-bus network with different locations of WSs.

  8. Pumped storage power stations. Overview of new projects in Austria

    Energy Technology Data Exchange (ETDEWEB)

    Berger, G. [KELAG-Kaerntner Elektrizitaets-Aktiengesellschaft, Klagenfurt (Austria). Production Div.; Puerer, E. [Vorarlberger Illwerke AG, Schruns (Austria). Engineering Div.

    2008-07-01

    New framework conditions, due to the liberalisation of the electricity market and the development of renewable energy, especially wind energy with its stochastic production, led to a renaissance of pump storage technology in central Europe. Austria is lucky, first of all in providing natural water resources as well as in topography highly suitable for hydro power plants. Pump storage power plants represent even today an essential asset of the Austrian energy production. A boom for the planning and the construction of new power plants can be also observed. Currently there are pump storage power plants with a total capacity of approximately 1.100 MW under construction as well as others of approximately 1.200 MW in the stage of concrete planning. (orig.)

  9. 78 FR 29022 - Safety Zone; Fourth of July Fireworks, Berkeley Marina, Berkeley, CA

    Science.gov (United States)

    2013-05-17

    ... SECURITY Coast Guard 33 CFR Part 165 Safety Zone; Fourth of July Fireworks, Berkeley Marina, Berkeley, CA... enforce the safety zone for the Berkeley Marina Fourth of July Fireworks display in the Captain of the... Berkeley Pier in approximate position 37 51'40'' N, 122 19'19'' W (NAD 83) from 9:30 p.m. until 10:15...

  10. Construction and preoperational test of Kashiwasaki-Kariwa Nuclear Power Station Unit No. 6

    Energy Technology Data Exchange (ETDEWEB)

    Natsume, Nobuo; Noda, Hiroshi [Tokyo Electric Power Co. (Japan)

    1996-12-31

    Unit 6 of the Kashiwazaki-Kariwa nuclear power station of Tokyo Electric Power Company, the world`s first advanced boiling water reactor (ABWR), is progressing ahead of the originally established schedule since the start of its construction in September 1991, and commercial operation is scheduled to start before the end of 1996.

  11. 75 FR 15744 - Omaha Public Power District; Fort Calhoun Station, Unit 1; Exemption

    Science.gov (United States)

    2010-03-30

    ... From the Federal Register Online via the Government Publishing Office NUCLEAR REGULATORY COMMISSION Omaha Public Power District; Fort Calhoun Station, Unit 1; Exemption 1.0 Background Omaha Public Power District (OPPD, the licensee) is the holder of Renewed Facility Operating License No. DPR-40 which authorizes operation of the Fort...

  12. 75 FR 42790 - Exelon Generation Company, LLC; Clinton Power Station; Environmental Assessment and Finding of No...

    Science.gov (United States)

    2010-07-22

    ... COMMISSION Exelon Generation Company, LLC; Clinton Power Station; Environmental Assessment and Finding of No...-62, issued to Exelon Generation Company, LLC (the licensee), for operation of the Clinton Power... have access to ADAMS or who encounter problems in accessing the documents located in ADAMS...

  13. Magnetic sensing for microstructural assessment of power station steels: Magnetic Barkhausen noise and minor loop measurements

    Science.gov (United States)

    Wilson, J. W.; Karimian, N.; Yin, W.; Liu, J.; Davis, C. L.; Peyton, A. J.

    2013-06-01

    There are currently no techniques available to monitor the microstructural condition of power station steel components in-service (at elevated temperatures). Electromagnetic (EM) inspection methods have the potential to provide a solution to this problem. Tests have been carried out on power generation steel (P9 and T22) samples with different microstructural states using major and minor B-H loop measurements and correlations established between EM properties and material properties such as Vickers hardness. These correlations will be used to develop a field deployable tool for the quantification of degradation in power station steels.

  14. Efforts toward enhancing seismic safety at Kashiwazaki Kariwa nuclear power station

    Energy Technology Data Exchange (ETDEWEB)

    Yamashita, Kazuhiko

    2010-09-15

    Kashiwazaki-Kariwa Nuclear Power Station, 8212MW, was struck by M6.8 quakes in July 2007. TEPCO has steadily been conducting restoration and post-earthquake equipment integrity assessment, aiming to make it a disaster-resistant power station. 2 units among 7 resumed commercial operation by June 2010. This earthquake has provided a great deal of knowledge and information useful for nuclear safety improvement. It has also served as a valuable reference for the IAEA in developing earthquake-related guidelines. TEPCO would like to share the knowledge and information thereby contributing to improving the safety of nuclear power generation. We will introduce some of our activities.

  15. Transient Processes in Electric Power Supply System for Oil Terminal with Own Gas-Turbine Power Station

    Directory of Open Access Journals (Sweden)

    A. M. Hаshimov

    2009-01-01

    Full Text Available The paper contains results of the investigations concerning influence of symmetrical and non-symmetrical short circuits at main power network on electric power supply system of a huge oil terminal which is powered by own gas-turbine power station. Calculations have been made in accordance with the IEC and IEEЕ requirements. Estimations for voltage level and distribution of short circuit current in the electric power supply system of the Sangachal oil terminal being operated in parallel with the AzerEnerji grid are presented in the paper

  16. Improving the Transient States Caused by Switching of Capacitor Banks in Power Dispatching Stations

    Directory of Open Access Journals (Sweden)

    Seyed Sajjad Salehi Ghaleh SEFID

    2014-09-01

    Full Text Available The high reactive power demand on the electrical power grid reduces the power factor and increases voltage drop. One of the compensation methods of required reactive power is the application of capacitor banks. Among the major problems with this equipment is shock, created at the moment of connection to the grid, which can cause accidents in power stations. While studying the statistical analysis of the incidents due to use of capacitor banks, this paper analyzes the shock caused by their connection, and realistically simulates a sample power station in the EMTP / WORKS software. Finally, this paper suggests useful and efficient methods to reduce the transient conditions caused by transient capacitor banks switching to the grid.

  17. In situ monitoring of animal micronuclei before the operation of Daya Bay Nuclear Power Station

    Energy Technology Data Exchange (ETDEWEB)

    Y.N. Cai; H.Y. He; L.M. Qian; G.C. Sun; J.Y. Zhao [Guangzhou College of Education, Guangzhou (China)

    1994-12-31

    Daya Bay Nuclear Power Station, a newly-built nuclear power station in southern mainland China, started its operation in 1993. We examined micro-nucleated cells of Invertibrate (Bivalves) and Vertibrate (Fish and Amphibia) in different spots within the 50km surroundings of the Power Station during 1986-1993. This paper reports the results of the investigation carried out in Dong Shan, a place 4.7km to the Power Station:Bivalves; Pteria martensil 5.1(1986),4.8(1988),4.8(1991),5,0(1993),Mytilus smardinus 4.7(1987),4.6(1988); Chamys nobilis 4.9(1987);4.9(1991),4.5(1992),4.5(1993). Fish; Therapon jarbua 0.48(1991),0.67(1992),0.47(1993). Amphibia; Bufo melanostictus 0.29 (1987), 0.34(1988),0.39(1992),0.39(1993). These results showed that the environmental situation, estimated by using the frequencies of micronucleated cells, was stable-there was no obvious chromosome damage in the animals studied. It was found that the incidence of micronucleated cells of Bivalves was higher than that of Fish and Amphibia, suggesting the epithelial cells to be more sensitive than peripheral erythrocytes to environmental genotoxic effects. The results of our studies for other spots will be reported afterward. These data can be used as the original background information to monitor the environment when the Nuclear Power Station is in operation.

  18. IMPLEMENTATION OF ENERGY LAW OF HYBRID POWER STATION FOR SOCIAL WELFARE

    Directory of Open Access Journals (Sweden)

    Dyah Ayu Widowati

    2014-11-01

    Full Text Available This study was aimed to investigate the Implementation of Energy Law of Hybrid Power Station for Social Welfare in Pantai Baru. The problem formulations are the management and utilization of hybrid power station in Pantai Baru and implementation of energy law of hybrid power station for social welfare in the fields of economy and information in Pantai Baru. Based on data analysis it is concluded that the management of hybrid power station in Pantai Baru is performed collaboratively between government and the society. The existence of hybrid power station in pantai baru has positive impacts in economy and information. Penelitian ini meneliti Pelaksanaan Hukum Energi Pembangkit Listrik Tenaga Hibrid untuk Kesejahteraan Rakyat di Bidang Ekonomi dan Informasi di Pantai Baru. Masalah yang diteliti adalah bentuk pengelolaan dan pemanfaatan pembangkit listrik tenaga hibrid di Pantai Baru dan pelaksanaan hukum energi pembangkit listrik tenaga hibrid untuk kesejahteraan rakyat di bidang ekonomi dan informasi di Pantai Baru. Berdasarkan analisis data dapat disimpulkan bahwa pengelolaan pembangkit listrik tenaga hibrid yang ada di pantai baru dilakukan secara kolaboratif, antara pemerintah dengan masyarakat. Kehadiran pembangkit listrik tenaga hibrid yang ada di pantai baru telah memberikan dampak positif di bidang ekonomi dan informasi.

  19. Berkeley Phylogenomics Group web servers: resources for structural phylogenomic analysis.

    Science.gov (United States)

    Glanville, Jake Gunn; Kirshner, Dan; Krishnamurthy, Nandini; Sjölander, Kimmen

    2007-07-01

    Phylogenomic analysis addresses the limitations of function prediction based on annotation transfer, and has been shown to enable the highest accuracy in prediction of protein molecular function. The Berkeley Phylogenomics Group provides a series of web servers for phylogenomic analysis: classification of sequences to pre-computed families and subfamilies using the PhyloFacts Phylogenomic Encyclopedia, FlowerPower clustering of proteins sharing the same domain architecture, MUSCLE multiple sequence alignment, SATCHMO simultaneous alignment and tree construction and SCI-PHY subfamily identification. The PhyloBuilder web server provides an integrated phylogenomic pipeline starting with a user-supplied protein sequence, proceeding to homolog identification, multiple alignment, phylogenetic tree construction, subfamily identification and structure prediction. The Berkeley Phylogenomics Group resources are available at http://phylogenomics.berkeley.edu.

  20. The Berkeley SETI program - SERENDIP IV instrumentation

    Science.gov (United States)

    Werthimer, Dan; Bowyer, Stuart; Ng, David; Donnelly, Charles; Cobb, Jeff; Lampton, Michael; Airieau, Sabine

    1997-01-01

    We discuss the hardware design of SERENDIP IV, which will be deployed in early 1997 for a 21-cm sky survey at the National Astronomy and Ionospheric Center's 305-m radio telescope in Arecibo, Puerto Rico. SERENDIP IV is a 167 million channel spectrum analyzer, covering a 100-Mhz bandwidth, with 0.6-Hz resolution and a 1.7-s integration time. SERENDIP IV's modular design incorporates a bank of digital mixers and filters to separate the 100 MHz band into 40 2.5 MHz subbands. Each 2.5 MHz subband is further broken down into 0.6 Hz bins by means of a four million point fast Fourier transform. The resulting power spectra are analyzed by 40 high-speed processors. Narrowband signals having power significantly above background noise levels are recorded along with telescope coordinates, time, and frequency. The data are sent in real time to Berkeley for analysis.

  1. Monitoring of Power Station Steels Using Electromagnetic Sensors

    OpenAIRE

    Karimian, Noushin

    2014-01-01

    With the world’s aging power generation network, especially in Europe and the United States, life-extension of steel plant components is increasingly a critical issue, as components are exposed to high temperatures and pressures during their lifetime, potentially resulting in carbide coarsening, making them prone to creep cavitation, possibly leading to component failure. Therefore, in order to evaluate the likelihood of component failure, non-destructive testing and evaluation procedures mus...

  2. Improving energy performance power station of ship with integrated electric propulsion

    Directory of Open Access Journals (Sweden)

    Dar’enkov Andrey

    2017-01-01

    Full Text Available The article presents the method of calculating the power plant fuel consumption on the basis of diesel-generating installation (DGI with variable speed for ships with integrated electric propulsion. Application DGI with variable speed allows saving fuel and therefore reducing harmful emissions into the atmosphere. In the paper calculated the fuel efficiency of unified power station on the basis of a variable speed DGI power of 1000 kW.

  3. Analysis of electromagnetic interference from power system processing and transmission components for Space Station Freedom

    Science.gov (United States)

    Barber, Peter W.; Demerdash, Nabeel A. O.; Hurysz, B.; Luo, Z.; Denny, Hugh W.; Millard, David P.; Herkert, R.; Wang, R.

    1992-01-01

    The goal of this research project was to analyze the potential effects of electromagnetic interference (EMI) originating from power system processing and transmission components for Space Station Freedom. The approach consists of four steps: (1) developing analytical tools (models and computer programs); (2) conducting parameterization (what if?) studies; (3) predicting the global space station EMI environment; and (4) providing a basis for modification of EMI standards.

  4. Central station applications planning activities and supporting studies. [application of photovoltaic technology to power generation plants

    Science.gov (United States)

    Leonard, S. L.; Siegel, B.

    1980-01-01

    The application of photovoltaic technology in central station (utility) power generation plants is considered. A program of data collection and analysis designed to provide additional information about the subset of the utility market that was identified as the initial target for photovoltaic penetration, the oil-dependent utilities (especially muncipals) of the U.S. Sunbelt, is described along with a series of interviews designed to ascertain utility industry opinions about the National Photovoltaic Program as it relates to central station applications.

  5. Avian radioecology on a nuclear power station site. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Levy, C.K.; Maletskos, C.J.; Youngstrom, K.A.

    1975-01-01

    A summary of a six-year avian radioecology study at the site of a nuclear power plant in Massachusetts is reported. A completed historical summary is followed by a description of mathematical models developed to calculate the effects on bird body burdens of various changes in environmental radionuclide levels. Examples are presented. Radionuclide metabolism studies in which acute doses of /sup 131/I and /sup 137/Cs were administered to four species of wild birds are presented. Radionuclides were administered both intravenously and orally; no apparent differences in uptake or elimination rates were observed between the two methods.

  6. Counter rotating type hydroelectric unit suitable for tidal power station

    Energy Technology Data Exchange (ETDEWEB)

    Kanemoto, T [Faculty of Engineering, Kyushu Institute of Technology, Sensui 1-1, Tobata, Kitakyushu 804-8550 (Japan); Suzuki, T, E-mail: turbo@tobata.isc.kyutech.ac.j [Graduate School of Engineering, Kyushu Institute of Technology, Sensui 1-1, Tobata, Kitakyushu 804-8550 (Japan)

    2010-08-15

    The counter rotating type hydroelectric unit, which is composed of the axial flow type tandem runners and the peculiar generator with double rotational armatures,was proposed to utilize effectively the tidal power. In the unit, the front and the rear runners counter drive the inner and the outer armatures of the generator, respectively. Besides, the flow direction at the rear runner outlet must coincide with the flow direction at the front runner inlet, because the angular momentum through the rear runner must coincides with that through the front runner. That is, the flow runs in the axial direction at the rear runner outlet while the axial inflow at the front runner inlet. Such operations are suitable for working at the seashore with rising and falling tidal flows, and the unit may be able to take place of the traditional bulb type turbines. The tandem runners were operated at the on-cam conditions, in keeping the induced frequency constant. The output and the hydraulic efficiency are affected by the adjustment of the front and the blade setting angles. The both optimum angles giving the maximum output and/or efficiency were presented at the various discharges/heads. To promote more the tidal power generation by this type unit, the runners were also modified so as to be suitable for both rising and falling flows. The hydraulic performances are acceptable while the output is determined mainly by the trailing edge profiles of the runner blades.

  7. Computer-integrated quality management system for power stations. Computer-integriertes Qualitaetsmanagementsystem fuer Kraftwerke

    Energy Technology Data Exchange (ETDEWEB)

    Durst, K.H.; Scheurer, K.; Meinhardt, H. (Siemens AG, Offenbach (Germany). Abt. Qualitaetssicherung)

    1993-03-01

    Conventional CAQ systems, which were developed for monitoring mass production, are not very suitable for quality assurance in the construction and operation of plant and power stations. Long life products have to be monitored in plant and power station construction, which were manufactured in small batches for individually. So that the quality of these products can be monitored and can be assured economically and reliably by preventive maintenance measures, it is necessary to combine the plant documentation, repeated tests and repair or replacement measures in a 'computer-integrated quality management system'. For large complex plants, such as power stations, an operation guidance system was developed which includes all important plant information and makes it available in a user-friendly way to the concern's management. The article introduces this system. (orig.).

  8. Macro mechanical parameters' size effect of surrounding rock of Shuibuya project's underground power station

    Institute of Scientific and Technical Information of China (English)

    GUO Zhi-hua; ZHOU Chuang-bing; ZHOU Huo-ming; SHENG Qian; LENG Xian-lun

    2005-01-01

    Scale effect is one of the important aspects in the macro mechanical parameters' research of rock mass, from a new point of view, by means of lab and field rock mechanics test, establishment of E~Vp relation, classification of engineering rock mass, numerical simulation test and back analysis based on surrounding rock's displacement monitoring results of Shuibuya Project's underground power station, rock mass deformation module's size effect of surrounding rock of Shuibuya Project's undegroud power station was studied. It's shown that rock mass deformation module's scale effect of surrounding rock of Shuibuya Project's undeground power station is obvious, the rock mass deformation module to tranquilization is 20% of intact rock's. Finally the relation between rock mass deformation modules and the scale of research was established.

  9. Small proton exchange membrane fuel cell power station by using bio-hydrogen

    Institute of Scientific and Technical Information of China (English)

    刘志祥; 毛宗强; 王诚; 任南琪

    2006-01-01

    In fermentative organic waste water treatment process, there was hydrogen as a by-product. After some purification,there was about 50% ~ 70% hydrogen in the bio-gas, which could be utilized for electricity generation with fuel cell. Half a year ago, joint experiments between biological hydrogen production in Harbin Institute of Technology (HIT) and proton exchange membrane fuel cell (PEMFC) power station in Tsinghua University were conducted for electricity generation with bio-hydrogen from the pilot plant in HIT. The results proved the feasibility of the bio-hydrogen as a by-product utilization with PEMFC power station and revealed some problems of fuel cell power station for this application.

  10. Design of Three Phase Solar-Based 4.5kw Ac Power Inverter Station

    Directory of Open Access Journals (Sweden)

    Dr.J.C. Onuegbu

    2013-07-01

    Full Text Available The design model of a 4.50Kilowatt, 3-phase, 50 hertz solar-based power generating station was examined by the paper. The power station is a dual source input generating station using 8 series connected 100A, 12V batteries per phase as backup, the solar panels being the main frame. An inverter of 12Volt direct current input voltage was incorporated to supply an output of 3-phase, 220Volts and 50 hertz alternating current. A charging circuit was installed to monitor charging level and to preserve the accumulator’s life span. The paper also looked into the solar-based power station component design model. The batteries therein are back-up and the system will ensure 24-hours reliable power supply. The setup has a normally closed switching relay ready to pickup the auxiliary battery supply within a few milliseconds after the solar source voltage drops below a stipulated level. The three phase a.c. voltage was achieved using standby on-line circuit with cascaded 741-based flip-flop at the base of the transistor drivers of the 3-phase power transformer. This model circuit reduced the load on each phase winding and facilitated reliable and uninterruptible power supply. The delta-wyeconnected transformer will guarantee proper phase shift of 120 degrees that will emulate alternating current voltage similar to the conventional generator voltage.

  11. Natural Disasters and Safety Risks at Nuclear Power Stations

    Science.gov (United States)

    Tutnova, T.

    2012-04-01

    In the aftermath of Fukushima natural-technological disaster the global opinion on nuclear energy divided even deeper. While Germany, Italy and the USA are currently reevaluating their previous plans on nuclear growth, many states are committed to expand nuclear energy output. In China and France, where the industry is widely supported by policymakers, there is little talk about abandoning further development of nuclear energy. Moreover, China displays the most remarkable pace of nuclear development in the world: it is responsible for 40% of worldwide reactors under construction, and aims at least to quadruple its nuclear capacity by 2020. In these states the consequences of Fukushima natural-technological accident will probably result in safety checks and advancement of new reactor technologies. Thus, China is buying newer reactor design from the USA which relies on "passive safety systems". It means that emergency power generators, crucial for reactor cooling in case of an accident, won't depend on electricity, so that tsunami won't disable them like it happened in the case of Fukushima. Nuclear energy managed to draw lessons from previous nuclear accidents where technological and human factors played crucial role. But the Fukushima lesson shows that the natural hazards, nevertheless, were undervalued. Though the ongoing technological advancements make it possible to increase the safety of nuclear power plants with consideration of natural risks, it is not just a question of technology improvement. A necessary action that must be taken is the reevaluation of the character and sources of the potential hazards which natural disasters can bring to nuclear industry. One of the examples is a devastating impact of more than one natural disaster happening at the same time. This subject, in fact, was not taken into account before, while it must be a significant point in planning sites for new nuclear power plants. Another important lesson unveiled is that world nuclear

  12. Control strategy for multi-pump emulsion power station in coal mine face

    Institute of Scientific and Technical Information of China (English)

    LI Wen-ying; WEI Jin-hong

    2011-01-01

    Shearer and hydraulic support are matching equipments.To increase the operating speed of the shearer,the following speed of hydraulic support must be increased.This means increasing the volume of flow from emulsion power station.Analyzing the operating characteristics of hydraulic supports,the number of simultaneously operating supports is obtained by means of pressure parameter and time history at a certain time,which is a theory base for development of control system to multi-pump emulsion power station.

  13. Automating security monitoring and analysis for Space Station Freedom's electric power system

    Science.gov (United States)

    Dolce, James L.; Sobajic, Dejan J.; Pao, Yoh-Han

    1990-01-01

    Operating a large, space power system requires classifying the system's status and analyzing its security. Conventional algorithms are used by terrestrial electric utilities to provide such information to their dispatchers, but their application aboard Space Station Freedom will consume too much processing time. A novel approach for monitoring and analysis using adaptive pattern techniques is presented. This approach yields an on-line security monitoring and analysis algorithm that is accurate and fast; and thus, it can free the Space Station Freedom's power control computers for other tasks.

  14. IMPROVEMENT OF EFFICIENCY AND ECONOMY OF STEAM TURBINE POWER STATIONS BY INTEN-SIFICATION OF HEAT TRANSFER

    Directory of Open Access Journals (Sweden)

    R. F. Kelbaliev

    2005-01-01

    Full Text Available Problem concerning improvement of operational efficiency of thermal power stations by intensification of heat transfer in various elements of equipment is of current concern in power engineering. The paper contains a large body of experimental data and some proposals are given how to apply them for operating equipment at thermal power stations.

  15. 75 FR 14634 - Dominion Nuclear Connecticut, Inc.; Millstone Power Station, Unit Nos. 1, 2, and 3; Environmental...

    Science.gov (United States)

    2010-03-26

    ... part 73, for certain uninterruptible power supply requirements. The proposed action, an extension of... COMMISSION Dominion Nuclear Connecticut, Inc.; Millstone Power Station, Unit Nos. 1, 2, and 3; Environmental... Power Station, Unit Nos. 1, 2, and 3 (MPS1, MPS2, and MPS3, respectively), located in New London...

  16. Decontamination of control rod housing from Palisades Nuclear Power Station.

    Energy Technology Data Exchange (ETDEWEB)

    Kaminski, M.D.; Nunez, L.; Purohit, A.

    1999-05-03

    Argonne National Laboratory has developed a novel decontamination solvent for removing oxide scales formed on ferrous metals typical of nuclear reactor piping. The decontamination process is based on the properties of the diphosphonic acids (specifically 1-hydroxyethane-1,1-diphosphonic acid or HEDPA) coupled with strong reducing-agents (e.g., sodium formaldehyde sulfoxylate, SFS, and hydroxylamine nitrate, HAN). To study this solvent further, ANL has solicited actual stainless steel piping material that has been recently removed from an operating nuclear reactor. On March 3, 1999 ANL received segments of control rod housing from Consumers Energy's Palisades Nuclear Plant (Covert, MI) containing radioactive contamination from both neutron activation and surface scale deposits. Palisades Power plant is a PWR type nuclear generating plant. A total of eight segments were received. These segments were from control rod housing that was in service for about 6.5 years. Of the eight pieces that were received two were chosen for our experimentation--small pieces labeled Piece A and Piece B. The wetted surfaces (with the reactor's pressurized water coolant/moderator) of the pieces were covered with as a scale that is best characterized visually as a smooth, shiny, adherent, and black/brown in color type oxide covering. This tenacious oxide could not be scratched or removed except by aggressive mechanical means (e.g., filing, cutting).

  17. The behaviour of coal blends in power station boilers

    Energy Technology Data Exchange (ETDEWEB)

    Livingston, W.R.; Horne, P.A.; McGhee, B.F.; Gibson, J.R. [Mitsui Babcock Energy Ltd., Renfrew (United Kingdom)

    1998-12-31

    The milling characteristics of coal blends were studied to provide quantitative information which allows the calculation of the Hardgrove Index (HGI) values of coal blends from those of the constituent coals; to provide data on the power requirement to produce a given mill output fineness, and abrasion rates of mill components when milling coal blends, relative to the behaviour of the constituent coals; to investigate the combustion behaviour of coal blends in pulverized fuel-fired systems by carrying out testwork in a semi-industrial combustion test facility, and to assess the deposition characteristics and the potential for utilization of the ashes produced by the combustion of coal blends. It was found that both the HGI and the Abrasion Index values of coals are additive properties. There were linear correlations between the slope of the Rosin-Rammler plot of the Mini-mill product size distribution and both the blend compositions and the HGI values of the coals and coal blends. Investigations showed that the fusion behaviour of the coal ash blends is rather complex, and that the characteristic ash fusion temperature are not additive in a simple way. A number of correlations were found between the ash fusion temperatures of the coals and coal ash blends. 1 ref., 45 figs., 10 tabs., 1 app.

  18. Time Averaged Transmitter Power and Exposure to Electromagnetic Fields from Mobile Phone Base Stations

    Directory of Open Access Journals (Sweden)

    Alfred Bürgi

    2014-08-01

    Full Text Available Models for exposure assessment of high frequency electromagnetic fields from mobile phone base stations need the technical data of the base stations as input. One of these parameters, the Equivalent Radiated Power (ERP, is a time-varying quantity, depending on communication traffic. In order to determine temporal averages of the exposure, corresponding averages of the ERP have to be available. These can be determined as duty factors, the ratios of the time-averaged power to the maximum output power according to the transmitter setting. We determine duty factors for UMTS from the data of 37 base stations in the Swisscom network. The UMTS base stations sample contains sites from different regions of Switzerland and also different site types (rural/suburban/urban/hotspot. Averaged over all regions and site types, a UMTS duty factor  for the 24 h-average is obtained, i.e., the average output power corresponds to about a third of the maximum power. We also give duty factors for GSM based on simple approximations and a lower limit for LTE estimated from the base load on the signalling channels.

  19. Time averaged transmitter power and exposure to electromagnetic fields from mobile phone base stations.

    Science.gov (United States)

    Bürgi, Alfred; Scanferla, Damiano; Lehmann, Hugo

    2014-08-07

    Models for exposure assessment of high frequency electromagnetic fields from mobile phone base stations need the technical data of the base stations as input. One of these parameters, the Equivalent Radiated Power (ERP), is a time-varying quantity, depending on communication traffic. In order to determine temporal averages of the exposure, corresponding averages of the ERP have to be available. These can be determined as duty factors, the ratios of the time-averaged power to the maximum output power according to the transmitter setting. We determine duty factors for UMTS from the data of 37 base stations in the Swisscom network. The UMTS base stations sample contains sites from different regions of Switzerland and also different site types (rural/suburban/urban/hotspot). Averaged over all regions and site types, a UMTS duty factor for the 24 h-average is obtained, i.e., the average output power corresponds to about a third of the maximum power. We also give duty factors for GSM based on simple approximations and a lower limit for LTE estimated from the base load on the signalling channels.

  20. Scheduled Operation of PV Power Station Considering Solar Radiation Forecast Error

    Science.gov (United States)

    Takayama, Satoshi; Hara, Ryoichi; Kita, Hiroyuki; Ito, Takamitsu; Ueda, Yoshinobu; Saito, Yutaka; Takitani, Katsuyuki; Yamaguchi, Koji

    Massive penetration of photovoltaic generation (PV) power stations may cause some serious impacts on a power system operation due to their volatile and unpredictable output. Growth of uncertainty may require larger operating reserve capacity and regulating capacity. Therefore, in order to utilize a PV power station as an alternative for an existing power plant, improvement in controllability and adjustability of station output become very important factor. Purpose of this paper is to develop the scheduled operation technique using a battery system (NAS battery) and the meteorological forecast. The performance of scheduled operation strongly depends on the accuracy of solar radiation forecast. However, the solar radiation forecast contains error. This paper proposes scheduling method and rescheduling method considering the trend of forecast error. More specifically, the forecast error scenario is modeled by means of the clustering analysis of the past actual forecast error. Validity and effectiveness of the proposed method is ascertained through computational simulations using the actual PV generation data monitored at the Wakkanai PV power station and solar radiation forecast data provided by the Japan Weather Association.

  1. Environmental Survey preliminary report, Lawrence Berkeley Laboratory, Berkeley, California

    Energy Technology Data Exchange (ETDEWEB)

    1988-07-01

    The purpose of this report is to present the preliminary findings made during the Environmental Survey, February 22--29, 1988, at the US Department of Energy (DOE) Lawrence Berkeley Laboratory (LBL) in Berkeley, California. The University of California operates the LBL facility for DOE. The LBL Survey is part of the larger DOE-wide Environmental Survey announced by Secretary John S. Herrington on September 18, 1985. The purpose of this effort is to identify, via no fault'' baseline Surveys, existing environmental problems and areas of environmental risk at DOE facilities, and to rank them on a DOE wide basis. This ranking will enable DOE to more effectively establish priorities for addressing environmental problems and allocate the resources necessary to correct them. Because the Survey is no fault'' and is not an audit,'' it is not designed to identify specific isolated incidents of noncompliance or to analyze environmental management practices. Such incidents and/or management practices will, however, be used in the Survey as a means of identifying existing and potential environmental problems. The LBL Survey was conducted by a multidisciplinary team of technical specialists headed and managed by a Team Leader and Assistant Team Leader from DOE's Office of Environmental Audit. A complete list of the LBL Survey participants and their affiliations is provided in Appendix A. 80 refs., 27 figs., 37 tabs.

  2. Two amateur astronomers at Berkeley

    CERN Document Server

    Sparavigna, Amelia Carolina

    2012-01-01

    The book on Mechanics of the Physics at Berkeley, by C. Kittel, W.D. Knight and M.A. Ruderman, is proposing at the end of its first chapter some problems of simple astronomy within the solar system. The discussion begins with two amateur astronomers who set for themselves the goal of determining the diameter and mass of the Sun. Here we discuss the problems proposed by the book and some other matters on ancient and modern astronomical studies of the solar system.

  3. Measuring Atmospheric Emissions of CH4 from Permafrost with Remote Low-Power Automated Stations

    Science.gov (United States)

    Burba, G. G.; Anderson, T.; Haapanala, S.; Mammarella, I.; McDermitt, D. K.; Oechel, W. C.; Peltola, O.; Rinne, J.; Schreiber, P.; Sturtevant, C. S.; Zulueta, R. C.

    2012-12-01

    Permafrost regions accumulate considerable amounts of organic materials held in anaerobic conditions. This leads to production and storage of CH4 in the upper layers of bedrock and soil, under the ice, and at lake bottoms. Presently, the permafrost is undergoing significant change in response to warming trends, and may become a significant source of CH4 release into the atmosphere. Direct measurements of CH4 emission in permafrost regions have most often been made with static chambers, and few were made using closed-path eddy flux stations. Although both approaches have advantages, they also have significant limitations. Static chamber measurements are discrete in time and space, and are particularly difficult to use over a polygonal tundra with highly non-uniform micro-topography and an active water layer. Closed-path gas analyzers for measuring CH4 eddy fluxes employ advanced laser technologies, but require high flow rates at significantly reduced optical cell pressures to provide adequate response time and sharpen absorption features. As a result, they require vacuum pumps and 400-1500 Watts of system power and can weigh over 100-200 lbs, restricting practical applicability for remote studies. As a result, spatial coverage of eddy flux measurements of CH4 in cold regions remains limited. Alternatively, open-path stations allow CH4 flux measurements at normal pressure without the need for a pump. As a result, the measurements can be done with very low-power (7-10 Watts) lightweight (11-12 lbs) arrangement permitting solar- and wind-powered deployments in remote sites using small automated stations. Such stations are important for a number of ecosystems (rice fields, landfills, wetlands, cattle yards), but are especially important for permafrost regions where grid power and access roads are generally not available. Emerging new research on CH4 flux measurements using automated low-power stations equipped with high-speed open-path CH4 analyzers are presented for a

  4. Diversion at small hydro-electric power stations; Forbislipping ved smaa vannkraftverk

    Energy Technology Data Exchange (ETDEWEB)

    Noren, Knut E.; Elstad, Ivar K.

    2008-07-01

    At a shut down caused by, for instance, a power shortage at a power station, the electric aggregate will stop and there will be a quick change in the flow of water downstream of the power station. This situation gives undesirable environmental effects, especially with regards to fish. The fish must have the opportunity to withdraw to deep pools, to avoid running aground. The goal of this report is to present good ideas to design diversion stations that reduce the environmental effects to an acceptable level, which is especially important in anadromous waterways, simultaneously not costing too much. The demand for diversion should be clarified with the authorities as soon as possible. By taking into account the power stations dimensions and foundation needs early on in the planning phase, the cost will be minimized. As a rule NVE currently demand that a diversion installation must have a capacity of 50 % of the turbines full flow of water. This is to avoid large changes in the flow of water downstream of the power station. In addition to the demand on the maximum capacity of the diversion installation, there should also be posed a demand that the calculation of the rate of flow should be kept within 50 % of the total rate of flow before the shut down. This is possible to achieve with the help of software control without the operational drawbacks caused by slow regulation being too great. Calculations carried out show that also with loading operation after shut down should have a relatively slow rate of flow. It is recommended that the short term rate of flow increase should be no more than 50 % of the rate of flow before the shut down or the stationary rate of flow before the turbines are started. To ensure the diversion with loading operation at small power stations it is recommended to use standard valves as much as possible, possibly with an energy dissipater that often can be manufactured locally. The installation should be arranged in such a way that the

  5. On the possibility of generation of cold and additional electric energy at thermal power stations

    Science.gov (United States)

    Klimenko, A. V.; Agababov, V. S.; Borisova, P. N.

    2017-06-01

    A layout of a cogeneration plant for centralized supply of the users with electricity and cold (ECCG plant) is presented. The basic components of the plant are an expander-generator unit (EGU) and a vapor-compression thermotransformer (VCTT). At the natural-gas-pressure-reducing stations, viz., gas-distribution stations and gas-control units, the plant is connected in parallel to a throttler and replaces the latter completely or partially. The plant operates using only the energy of the natural gas flow without burning the gas; therefore, it can be classified as a fuelless installation. The authors compare the thermodynamic efficiencies of a centralized cold supply system based on the proposed plant integrated into the thermal power station scheme and a decentralized cold supply system in which the cold is generated by electrically driven vapor-compression thermotransformers installed on the user's premises. To perform comparative analysis, the exergy efficiency was taken as the criterion since in one of the systems under investigation the electricity and the cold are generated, which are energies of different kinds. It is shown that the thermodynamic efficiency of the power supply using the proposed plant proves to be higher within the entire range of the parameters under consideration. The article presents the results of investigating the impact of the gas heating temperature upstream from the expander on the electric power of the plant, its total cooling capacity, and the cooling capacities of the heat exchangers installed downstream from the EGU and the evaporator of the VCTT. The results of calculations are discussed that show that the cold generated at the gas-control unit of a powerful thermal power station can be used for the centralized supply of the cold to the ventilation and conditioning systems of both the buildings of the power station and the neighboring dwelling houses, schools, and public facilities during the summer season.

  6. Reactive Power Support of Electrical Vehicle Charging Station Upgraded with Flywheel Energy Storage System

    DEFF Research Database (Denmark)

    SUN, BO; Dragicevic, Tomislav; Savaghebi, Mehdi

    2015-01-01

    the operation of each component in the system. As a result, the charging station could supply the reactive power support to the utility grid without compromising the charging algorithm and preserve the battery’s lifetime. Finally, the real-time simulation results based on dSPACE1006 verifies the proposed......Electrical vehicles (EVs) are presenting increasingly potential to replace the conventional fossil fuel based vehicles due to environmental friendly characteristic. Accordingly, Charging Stations (CS), as an intermediate between grid and large numbers of EVs, are supposed to have more critical...... influence on future smart transportation network. This paper explores an off-board charging station upgraded with flywheel energy storage system that could provide a reactive power support to the grid utility. A supervisory control scheme based on distributed bus signaling is proposed to coordinate...

  7. Magnetic sensing for microstructural assessment of power station steels: Magnetic Barkhausen noise and minor loop measurements

    OpenAIRE

    Wilson, JWa; Karimian, N a; Yin, W a; Liu, J. B.; Davis, CLb; Peyton, AJa

    2013-01-01

    There are currently no techniques available to monitor the microstructural condition of power station steel components in-service (at elevated temperatures). Electromagnetic (EM) inspection methods have the potential to provide a solution to this problem. Tests have been carried out on power generation steel (P9 and T22) samples with different microstructural states using major and minor B-H loop measurements and correlations established between EM properties and material properties such as V...

  8. New fossil-fired power stations in Europe. Status and perspectives

    Energy Technology Data Exchange (ETDEWEB)

    Benesch, Wolfgang A. [Evonik Energy Services, Essen (Germany); Pasini, Sauro [Enel Engineering and Innovation Research, Pisa (Italy)

    2011-07-01

    The security of electricity supply in Europe can only be assured by a well-balanced energy mix. To ensure the increasing amount of stochastic renewable sources like e.g. wind and solar power, economically competitive coal- and gas-fired power stations are needed. Nevertheless, currently more and more projects are stopped and postponed. In that context questions like: What is the background? What is the current situation? What should be? What are the causes? What is needed? are discussed. (orig.)

  9. Study of mercury in by-products from a Dutch co-combustion power station

    OpenAIRE

    Rallo, Manuela; López Antón, María Antonia; Meij, Ruud; Perry, Ron; Maroto Valer, Mercedes

    2010-01-01

    [EN] Fly ashes and gypsum are one of the main wastes produced in coal-fired power stations which may be sent to landfills for their disposal. In this work, leaching and speciation of mercury in fly ashes and gypsum from a modern co-combustion power plant equipped with a selective catalytic reduction (SCR) unit in the Netherlands were studied. The mercury leachable contents were checked against different regulations, including Dutch, German and the Council Directive 2003/33/EC. The speciation ...

  10. Test on the 30kW Vibrating Wave-power Station Accepted in China

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    To meet the demand of island residents on the electric power for their daily lives, a 30kW vibrating wavepower station, designed and built by the Oceanic Technology Research Institute of China National Bureau of Ocean, is presently conducted with test in Jimo city of Shangdong province, and accepted by China National Bureau of Ocean and China's Academy of Science.

  11. 75 FR 16523 - FirstEnergy Nuclear Operating Company; Davis-Besse Nuclear Power Station; Exemption

    Science.gov (United States)

    2010-04-01

    ... COMMISSION FirstEnergy Nuclear Operating Company; Davis-Besse Nuclear Power Station; Exemption 1.0 Background FirstEnergy Nuclear Operating Company (FENOC, the licensee) is the holder of Facility Operating License... M.S. Fertel, Nuclear Energy Institute). The licensee's request for an exemption is...

  12. Influence of Frequency Converters on Insulation of Power Supply Cables at Oil-Producing Stations

    Directory of Open Access Journals (Sweden)

    D. I. Zalizny

    2011-01-01

    Full Text Available The paper considers consequences of negative frequency converter influence on insulation of  power supply cables used for submersible installations of electric-centrifugal pumps at oil-producing stations. The possible approaches to the solution of the problem are proposed on the basis of a harmonic analysis of actually measured voltages and currents in a cable.  

  13. MODELING OF WIND LOADS ACTING ON THE WIND POWER STATION CONSTRUCTION OF THE COMBINED TYPE

    Directory of Open Access Journals (Sweden)

    Bukhtoyarova E. S.

    2014-04-01

    Full Text Available The article presents the solution of questions about the intensity of wind loads acting on the wind power station of the combined type in relation to the conditions of the Rostov region on the basis of the structural dynamic simulation

  14. Fatigue Life Prediction of Mooring Chains for a Floating Tidal Current Power Station

    Institute of Scientific and Technical Information of China (English)

    Fengmei Jing; Liang Zhang; Zhong Yang

    2012-01-01

    As a kind of clean and renewable energy,tidal current energy is becoming increasingly popular all over the world with the shortage of energy and environmental problems becoming more and more severe.A floating tidal current power station is a typical type of tidal current power transformers which can sustain the loads of wind,waves,and current,and even the extreme situation of a typhoon.Therefore,the mooring system must be reliable enough to keep the station operating normally and to survive in extreme situations.The power station examined in this paper was installed at a depth of 40 m.A 44 mm-diameter R4-RQ4 chain was chosen,with a 2 147 kN minimum break strength and 50 kN pretension.Common studless link chain was used in this paper.Based on the Miner fatigue cumulative damage rule,S-N curves of chains,and MOSES software,a highly reliable mooring system was designed and analyzed.The calculation results show that the mooring system designed is reliable throughout a 10-year period.It can completely meet the design requirements of American Petroleum institution (API).Therefore,the presented research is significant for advancing the design of this kind of power station.

  15. The NASA-Lewis terrestrial photovoltaics program. [solar cell power system for weather station

    Science.gov (United States)

    Bernatowicz, D. T.

    1973-01-01

    Research and technology efforts on solar cells and arrays having relevance to terrestrial uses are outline. These include raising cell efficiency, developing the FEP-covered module concept, and exploring low cost cell concepts. Solar cell-battery power systems for remote weather stations have been built to demonstrate the capabilities of solar cells for terrestrial applications.

  16. 77 FR 59679 - Central Vermont Public Service Corporation (Millstone Power Station, Unit 3); Order Approving...

    Science.gov (United States)

    2012-09-28

    .... (DNC), Central Vermont Public Service Corporation (CVPS) and Massachusetts Municipal Wholesale Electric Company (MMWE) (collectively ``the licensees'' or ``DNC, Inc., et al.'') are the co-holders of the Renewed... Power Station, Unit 3 (MPS3). CVPS is a non-operating owner of a 1.7303% interest in MPS3. DNC is...

  17. 77 FR 35080 - Entergy Nuclear Operations, Inc., Pilgrim Nuclear Power Station; Record of Decision and Issuance...

    Science.gov (United States)

    2012-06-12

    ... fossil fuel generation, renewable energy sources, demand-side measures such as energy conservation, and... From the Federal Register Online via the Government Publishing Office NUCLEAR REGULATORY COMMISSION Entergy Nuclear Operations, Inc., Pilgrim Nuclear Power Station; Record of Decision and Issuance...

  18. Technological scheme for the waste-free treatment of thermal power station ash

    Energy Technology Data Exchange (ETDEWEB)

    Tyurnikova, V.I.; Krasnikova, N.A.; Panin, A.S.; Konovalenko, P.F.

    1979-01-01

    Flotation is used to process fly ash. In an example given, an ash containing 9% carbon is treated with an apolar collecting agent which gives a product with a calorific value of 4,000 kcal/kg, suitable for combustion in a power station. The ash content of the refuse is 98.6%.

  19. Model Predictive Control of Offshore Power Stations With Waste Heat Recovery

    DEFF Research Database (Denmark)

    Pierobon, Leonardo; Chan, Richard; Li, Xiangan;

    2016-01-01

    The implementation of waste heat recovery units on oil and gas offshore platforms demands advances in both design methods and control systems. Model-based control algorithms can play an important role in the operation of offshore power stations. A novel regulator based on a linear model predictive...

  20. [Risk of electromagnetic fields in electric power stations and substations of a petrochemical plant].

    Science.gov (United States)

    Castagnoli, A; Fabri, G; Romeo, A

    2003-01-01

    Authors evaluate electromagnetic field exposure in the low-frequency range (5-30,000 Hz) in electric power stations and substations of petroleum processing plant. According to the measured values and the reference exposure limits considered, they conclude that operators should be exposed without adverse effects.

  1. Analysis of the Use of Wind Energy to Supplement the Power Needs at McMurdo Station and Amundsen-Scott South Pole Station, Antarctica (Poster)

    Energy Technology Data Exchange (ETDEWEB)

    Baring-Gould, E. I.; Robichaud, R.; McLain, K.

    2005-05-01

    This poster summarizes the analysis of the inclusion of wind-driven power generation technology into the existing diesel power plants at two U.S. Antarctic research stations, McMurdo and Amundsen-Scott South Pole Station. Staff at the U.S. Department of Energy's National Renewable Energy Laboratory (NREL) conducted the analysis. Available data were obtained on the wind resources, power plant conditions, load, and component cost. We then used NREL's Hybrid2 power system modeling software to analyze the potential and cost of using wind turbine generators at the two aforementioned facilities.

  2. 77 FR 37604 - Safety Zone; Fourth of July Fireworks, Berkeley Marina, Berkeley, CA

    Science.gov (United States)

    2012-06-22

    ... SECURITY Coast Guard 33 CFR Part 165 Safety Zone; Fourth of July Fireworks, Berkeley Marina, Berkeley, CA... enforce the safety zone for the Berkeley Marina Fourth of July Fireworks display in the Captain of the... Berkeley Pier in position 37 51'40'' N, 122 19'19'' W (NAD 83) from 9:30 p.m. until 10:15 p.m. on July...

  3. Observations of Earth space by self-powered stations in Antarctica.

    Science.gov (United States)

    Mende, S B; Rachelson, W; Sterling, R; Frey, H U; Harris, S E; McBride, S; Rosenberg, T J; Detrick, D; Doolittle, J L; Engebretson, M; Inan, U; Labelle, J W; Lanzerotti, L J; Weatherwax, A T

    2009-12-01

    Coupling of the solar wind to the Earth magnetosphere/ionosphere is primarily through the high latitude regions, and there are distinct advantages in making remote sensing observations of these regions with a network of ground-based observatories over other techniques. The Antarctic continent is ideally situated for such a network, especially for optical studies, because the larger offset between geographic and geomagnetic poles in the south enables optical observations at a larger range of magnetic latitudes during the winter darkness. The greatest challenge for such ground-based observations is the generation of power and heat for a sizable ground station that can accommodate an optical imaging instrument. Under the sponsorship of the National Science Foundation, we have developed suitable automatic observing platforms, the Automatic Geophysical Observatories (AGOs) for a network of six autonomous stations on the Antarctic plateau. Each station housed a suite of science instruments including a dual wavelength intensified all-sky camera that records the auroral activity, an imaging riometer, fluxgate and search-coil magnetometers, and ELF/VLF and LM/MF/HF receivers. Originally these stations were powered by propane fuelled thermoelectric generators with the fuel delivered to the site each Antarctic summer. A by-product of this power generation was a large amount of useful heat, which was applied to maintain the operating temperature of the electronics in the stations. Although a reasonable degree of reliability was achieved with these stations, the high cost of the fuel air lift and some remaining technical issues necessitated the development of a different type of power unit. In the second phase of the project we have developed a power generation system using renewable energy that can operate automatically in the Antarctic winter. The most reliable power system consists of a type of wind turbine using a simple permanent magnet rotor and a new type of power

  4. Observations of Earth space by self-powered stations in Antarctica

    Science.gov (United States)

    Mende, S. B.; Rachelson, W.; Sterling, R.; Frey, H. U.; Harris, S. E.; McBride, S.; Rosenberg, T. J.; Detrick, D.; Doolittle, J. L.; Engebretson, M.; Inan, U.; Labelle, J. W.; Lanzerotti, L. J.; Weatherwax, A. T.

    2009-12-01

    Coupling of the solar wind to the Earth magnetosphere/ionosphere is primarily through the high latitude regions, and there are distinct advantages in making remote sensing observations of these regions with a network of ground-based observatories over other techniques. The Antarctic continent is ideally situated for such a network, especially for optical studies, because the larger offset between geographic and geomagnetic poles in the south enables optical observations at a larger range of magnetic latitudes during the winter darkness. The greatest challenge for such ground-based observations is the generation of power and heat for a sizable ground station that can accommodate an optical imaging instrument. Under the sponsorship of the National Science Foundation, we have developed suitable automatic observing platforms, the Automatic Geophysical Observatories (AGOs) for a network of six autonomous stations on the Antarctic plateau. Each station housed a suite of science instruments including a dual wavelength intensified all-sky camera that records the auroral activity, an imaging riometer, fluxgate and search-coil magnetometers, and ELF/VLF and LM/MF/HF receivers. Originally these stations were powered by propane fuelled thermoelectric generators with the fuel delivered to the site each Antarctic summer. A by-product of this power generation was a large amount of useful heat, which was applied to maintain the operating temperature of the electronics in the stations. Although a reasonable degree of reliability was achieved with these stations, the high cost of the fuel air lift and some remaining technical issues necessitated the development of a different type of power unit. In the second phase of the project we have developed a power generation system using renewable energy that can operate automatically in the Antarctic winter. The most reliable power system consists of a type of wind turbine using a simple permanent magnet rotor and a new type of power

  5. STUDY ON POWER SPARE COEFFICIENT OF ELECTRICAL MOTOR IN LARGE PUMP STATION BASED ON RELIABILITY

    Institute of Scientific and Technical Information of China (English)

    Qiu Baoyun; Huang Jiyan; Yuan Shouqi

    2004-01-01

    Characters of head of low head pump station and the pump shaft power are analyzed. Influence of each single factor on pump shaft power is expressed as change of specific shaft power (non-dimensional) and the probability density function is determined. Influences of multiple factors on pump shaft power are analyzed. Method of calculating none over-loaded probability of motor by integration by successive reductions is put forward and then relation between power spare coefficient and none over-loaded reliability of electric motor is established. Influences of all factors on pump shaft power being considered completely; power spare coefficients of motor are calculated in three kinds of heads (changing and unchanging), two kinds of dirty-out conditions. Electrical motor power spare coefficients should be chosen as 1.20~1.44, 1.11~1.19, 1.09~1.14 respectively when pump heads are 4, 7, 9.5 m. The results mean much to reasonable choose of electrical motors in large pump stations, increasing reliability of pump units and saving equipment investment.

  6. Implicit attitudes toward nuclear power and mobile phone base stations: support for the affect heuristic.

    Science.gov (United States)

    Siegrist, Michael; Keller, Carmen; Cousin, Marie-Eve

    2006-08-01

    The implicit association test (IAT) measures automatic associations. In the present research, the IAT was adapted to measure implicit attitudes toward technological hazards. In Study 1, implicit and explicit attitudes toward nuclear power were examined. Implicit measures (i.e., the IAT) revealed negative attitudes toward nuclear power that were not detected by explicit measures (i.e., a questionnaire). In Study 2, implicit attitudes toward EMF (electro-magnetic field) hazards were examined. Results showed that cell phone base stations and power lines are judged to be similarly risky and, further, that base stations are more closely related to risk concepts than home appliances are. No differences between experts and lay people were observed. Results of the present studies are in line with the affect heuristic proposed by Slovic and colleagues. Affect seems to be an important factor in risk perception.

  7. Allowable Residual Contamination Levels in soil for decommissioning the Shippingport Atomic Power Station site

    Energy Technology Data Exchange (ETDEWEB)

    Kennedy, W.E. Jr.; Napier, B.A.; Soldat, J.K.

    1983-09-01

    As part of decommissioning the Shippingport Atomic Power Station, a fundamental concern is the determination of Allowable Residual Contamination Levels (ARCL) for radionuclides in the soil at the site. The ARCL method described in this report is based on a scenario/exposure-pathway analysis and compliance with an annual dose limit for unrestricted use of the land after decommissioning. In addition to naturally occurring radionuclides and fallout from weapons testing, soil contamination could potentially come from five other sources. These include operation of the Shippingport Station as a pressurized water reactor, operations of the Shippingport Station as a light-water breeder, operation of the nearby Beaver Valley reactors, releases during decommissioning, and operation of other nearby industries, including the Bruce-Mansfield coal-fired power plants. ARCL values are presented for 29 individual radionculides and a worksheet is provided so that ARCL values can be determined for any mixture of the individual radionuclides for any annual dose limit selected. In addition, a worksheet is provided for calculating present time soil concentration value that will decay to the ARCL values after any selected period of time, such as would occur during a period of restricted access. The ARCL results are presented for both unconfined (surface) and confined (subsurface) soil contamination. The ARCL method and results described in this report provide a flexible means of determining unrestricted-use site release conditions after decommissioning the Shippingport Atomic Power Station.

  8. Development of a Cost-Effective Solar/Diesel Independent Power Plant for a Remote Station

    Directory of Open Access Journals (Sweden)

    Okeolu Samuel Omogoye

    2015-01-01

    Full Text Available The paper discusses the design, simulation, and optimization of a solar/diesel hybrid power supply system for a remote station. The design involves determination of the station total energy demand as well as obtaining the station solar radiation data. This information was used to size the components of the hybrid power supply system (HPSS and to determine its configuration. Specifically, an appropriate software package, HOMER, was used to determine the number of solar panels, deep-cycle batteries, and rating of the inverter that comprise the solar section of the HPSS. A suitable diesel generator was also selected for the HPSS after careful technical and cost analysis of those available in the market. The designed system was simulated using the HOMER software package and the simulation results were used to carry out the optimization of the system. The final design adequately meets the station energy requirement. Based on a life expectancy of twenty-five years, a cost-benefit analysis of the HPSS was carried out. This analysis shows that the HPSS has a lower cost as compared to a conventional diesel generator power supply, thus recommending the HPSS as a more cost-effective solution for this application.

  9. The effects of solar-geomagnetically induced currents on electrical systems in nuclear power stations

    Energy Technology Data Exchange (ETDEWEB)

    Subudhi, M. [Brookhaven National Lab., Upton, NY (United States); Carroll, D.P. [Florida Univ., Gainesville, FL (United States); Kasturi, S. [MOS, Inc., Melville, NY (United States)

    1994-01-01

    This report presents the results of a study to evaluate the potential effects of geomagnetically induced currents (GICs) caused by the solar disturbances on the in-plant electrical distribution system and equipment in nuclear power stations. The plant-specific electrical distribution system for a typical nuclear plant is modeled using the ElectroMagnetic Transient Program (EMTP). The computer model simulates online equipment and loads from the station transformer in the switchyard of the power station to the safety-buses at 120 volts to which all electronic devices are connected for plant monitoring. The analytical model of the plant`s electrical distribution system is studied to identify the transient effects caused by the half-cycle saturation of the station transformers due to GIC. This study provides results of the voltage harmonics levels that have been noted at various electrical buses inside the plant. The emergency circuits appear to be more susceptible to high harmonics due to the normally light load conditions. In addition to steady-state analysis, this model was further analyzed simulating various plant transient conditions (e.g., loss of load or large motor start-up) occurring during GIC events. Detail models of the plant`s protective relaying system employed in bus transfer application were included in this model to study the effects of the harmonic distortion of the voltage input. Potential harmonic effects on the uniterruptable power system (UPS) are qualitatively discussed as well.

  10. Project risk control of underground engineering geological disaster in pumped-storage power station

    Institute of Scientific and Technical Information of China (English)

    Luo Shaoji

    2014-01-01

    This paper introduced the construction of the pumped-storage power station (PSPS). In the excava- tion of underground power house, the principle of excavation in thin layer and support in time with real time monitoring are adopted. The excavation blasting parameters are adjusted timely. Through these, the excavation quality can be guaranteed, the surrounding rock can be prevented from being damaged and the deformation of power house side wall can be controlled. Five security defense lines have been adopted to solve anti-seepage and drainage in the major underground projects.

  11. Project risk control of underground engineering geological disaster in pumped-storage power station

    Institute of Scientific and Technical Information of China (English)

    Luo Shaoji

    2014-01-01

    This paper introduced the construction of the pumped-storage power station (PSPS). In the excava-tion of underground power house,the principle of excavation in thin layer and support in time with real time monitoring are adopted. The excavation blasting parameters are adjusted timely. Through these,the excavation quality can be guaranteed,the surrounding rock can be prevented from being damaged and the deformation of power house side wall can be controlled. Five security defense lines have been adopted to solve anti-seepage and drainage in the major underground projects.

  12. MHD-steam thermal power plant electrical stations with zero stack emission

    Energy Technology Data Exchange (ETDEWEB)

    Borghi, C.A.; Botti, M.; Ribani, P.L. [Univ. of Bologna (Italy)

    1994-12-31

    In the present work a system study of a combined cycle MHD-steam thermal power plant electrical station with zero stack emission through recirculation of CO{sub 2}, is presented. The design of the MHD generator of the topper is done by means of a quasi-one-dimensional optimisation model. The thermodynamic of the combustion gas, typical of this cycle, is considered. The technology of the components is conventional. An overall efficiency larger than 41% for power plants with electrical power inputs above 600 MWe, are obtained.

  13. The European fossil-fuelled power station database used in the SEI CASM model

    Energy Technology Data Exchange (ETDEWEB)

    Bailey, P. [comp.] [Stockholm Environment Inst. at York (United Kingdom)

    1996-06-01

    The database contains details of power stations in Europe that burn fossil-fuels. All countries are covered from Ireland to the European region of Russia as far as the Urals. The following data are given for each station: Location (country and EMEP square), capacity (net MW{sub e} and boiler size), year of commissioning, and fuels burnt. A listing of the database is included in the report. The database is primarily used for estimation of emissions and abatement costs of sulfur and nitrogen oxides in the SEI acid rain model CASM. 24 refs, tabs

  14. Proceedings of scientific-technical seminar: materials investigation for power stations and power grid; Seminarium naukowo-techniczne: Badania materialowe na potrzeby elektrowni i sieci elektroenergetycznych

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-05-01

    This report is an assembly of the papers concerning the material problems occurring during the exploitation of power stations as well as power grid. The diagnostic methods are also discussed. (author).

  15. Estimation of Power Production Potential from Natural Gas Pressure Reduction Stations in Pakistan Using ASPEN HYSYS

    Directory of Open Access Journals (Sweden)

    Imran Nazir Unar

    2015-07-01

    Full Text Available Pakistan is a gas rich but power poor country. It consumes approximately 1, 559 Billion cubic feet of natural gas annually. Gas is transported around the country in a system of pressurized transmission pipelines under a pressure range of 600-1000 psig exclusively operated by two state owned companies i.e. SNGPL (Sui Northern Gas Pipelines Limited and SSGCL (Sui Southern Gas Company Limited. The gas is distributed by reducing from the transmission pressure into distribution pressure up to maximum level of 150 psig at the city gate stations normally called SMS (Sales Metering Station. As a normal practice gas pressure reduction at those SMSs is accomplished in pressure regulators (PCVs or in throttle valves where isenthalpic expansion takes place without producing any energy. Pressure potential of natural gas is an untapped energy resource which is currently wasted by its throttling. This pressure reduction at SMS (pressure drop through SMS may also be achieved by expansion of natural gas in TE, which converts its pressure into the mechanical energy, which can be transmitted any loading device for example electric generator. The aim of present paper is to explore the expected power production potential of various Sales Metering Stations of SSGCL company in Pakistan. The model of sales metering station was developed in a standard flow sheeting software Aspen HYSYS®7.1 to calculate power and study other parameters when an expansion turbine is used instead of throttling valves. It was observed from the simulation results that a significant power (more than 140 KW can be produced at pressure reducing stations of SSGC network with gas flows more than 2.2 MMSCFD and pressure ration more than 1.3.

  16. 47 CFR 73.6012 - Protection of Class A TV, low power TV and TV translator stations.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Protection of Class A TV, low power TV and TV... of Class A TV, low power TV and TV translator stations. An application to change the facilities of an existing Class A TV station will not be accepted if it fails to protect other authorized Class A TV,...

  17. 76 FR 23846 - Virginia Electric Power Company, LLC, North Anna Power Station, Unit No. 1; Exemption

    Science.gov (United States)

    2011-04-28

    ... licensee described elements of their fire protection program that provide their justification that the... source is effectively eliminated. In addition, guidance in the ``Station Lubrication Manual'' outlines... Lubrication Manual is procedurally controlled and requires authorization to be changed. With the exception...

  18. SOARCA Peach Bottom Atomic Power Station Long-Term Station Blackout Uncertainty Analysis: Convergence of the Uncertainty Results

    Energy Technology Data Exchange (ETDEWEB)

    Bixler, Nathan E.; Osborn, Douglas.; Sallaberry, Cedric Jean-Marie; Eckert-Gallup, Aubrey Celia; Mattie, Patrick D.; Ghosh, S. Tina

    2014-02-01

    This paper describes the convergence of MELCOR Accident Consequence Code System, Version 2 (MACCS2) probabilistic results of offsite consequences for the uncertainty analysis of the State-of-the-Art Reactor Consequence Analyses (SOARCA) unmitigated long-term station blackout scenario at the Peach Bottom Atomic Power Station. The consequence metrics evaluated are individual latent-cancer fatality (LCF) risk and individual early fatality risk. Consequence results are presented as conditional risk (i.e., assuming the accident occurs, risk per event) to individuals of the public as a result of the accident. In order to verify convergence for this uncertainty analysis, as recommended by the Nuclear Regulatory Commission’s Advisory Committee on Reactor Safeguards, a ‘high’ source term from the original population of Monte Carlo runs has been selected to be used for: (1) a study of the distribution of consequence results stemming solely from epistemic uncertainty in the MACCS2 parameters (i.e., separating the effect from the source term uncertainty), and (2) a comparison between Simple Random Sampling (SRS) and Latin Hypercube Sampling (LHS) in order to validate the original results obtained with LHS. Three replicates (each using a different random seed) of size 1,000 each using LHS and another set of three replicates of size 1,000 using SRS are analyzed. The results show that the LCF risk results are well converged with either LHS or SRS sampling. The early fatality risk results are less well converged at radial distances beyond 2 miles, and this is expected due to the sparse data (predominance of “zero” results).

  19. Life sciences: Lawrence Berkeley Laboratory, 1988

    Energy Technology Data Exchange (ETDEWEB)

    1989-07-01

    Life Sciences Research at LBL has both a long history and a new visibility. The physics technologies pioneered in the days of Ernest O. Lawrence found almost immediate application in the medical research conducted by Ernest's brother, John Lawrence. And the tradition of nuclear medicine continues today, largely uninterrupted for more than 50 years. Until recently, though, life sciences research has been a secondary force at the Lawrence Berkeley Laboratory (LBL). Today, a true multi-program laboratory has emerged, in which the life sciences participate as a full partner. The LBL Human Genome Center is a contribution to the growing international effort to map the human genome. Its achievements represent LBL divisions, including Engineering, Materials and Chemical Sciences, and Information and Computing Sciences, along with Cell and Molecular Biology and Chemical Biodynamics. The Advanced Light Source Life Sciences Center will comprise not only beamlines and experimental end stations, but also supporting laboratories and office space for scientists from across the US. This effort reflects a confluence of scientific disciplines --- this time represented by individuals from the life sciences divisions and by engineers and physicists associated with the Advanced Light Source project. And finally, this report itself, the first summarizing the efforts of all four life sciences divisions, suggests a new spirit of cooperation. 30 figs.

  20. Provision of Continuity in Power Supply of Wind Power Stations by Improvement of Methods for Control of Oil Transformer Serviceability

    Directory of Open Access Journals (Sweden)

    Y. A. Rolik

    2010-01-01

    Full Text Available The paper considers problems pertaining to reduction of time for restoration of a wind power station (WPS by development of a method and control means according to informative parameter. A high-voltage oil transformer has been selected as a control WPS object.  The paper shows that the most informative parameter determining continuity in WPS power supply is an over-heating temperature of oil transformer elements. A method and means for control of WPS oil transformer serviceability are proposed in the paper.

  1. Numerical analysis of transient pressure variation in the condenser of a nuclear power station

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Xinjun; Zhou, Zijie; Song, Zhao [Xi' an Jiaotong University, Xi' an (China); Lu, Qiankui; Li, Jiafu [Dong Fang Turbine Co., Ltd, Deyang (China)

    2016-02-15

    To research the characteristics of the transient variation of pressure in a nuclear power station condenser under accident condition, a mathematical model was established which simulated the cycling cooling water, heat transfer and pressure in the condenser. The calculation program of transient variation characteristics was established in Fortran language. The pump's parameter, cooling line's organization, check valve's feature and the parameter of siphonic water-collecting well are involved in the cooling water flow's mathematical model. The initial conditions of control volume are determined by the steady state of the condenser. The transient characteristics of a 1000 MW nuclear power station's condenser and cooling water system were examined. The results show that at the condition of plant-power suspension of pump, the cooling water flow rate decreases rapidly and refluxes, then fluctuates to 0. The variation of heat transfer coefficient in the condenser has three stages: at start it decreases sharply, then increases and decreases, and keeps constant in the end. Under three conditions (design, water and summer), the condenser pressure goes up in fluctuation. The time intervals between condenser's pressure signals under three conditions are about 26.4 s, which can fulfill the requirement for safe operation of nuclear power station.

  2. Modeling of a Photovoltaic-Powered Electric Vehicle Charging Station with Vehicle-to-Grid Implementation

    Directory of Open Access Journals (Sweden)

    Azhar Ul-Haq

    2016-12-01

    Full Text Available This paper is aimed at modelling of a distinct smart charging station for electric vehicles (EVs that is suitable for DC quick EV charging while ensuring minimum stress on the power grid. Operation of the charging station is managed in such a way that it is either supplied by photovoltaic (PV power or the power grid, and the vehicle-to-grid (V2G is also implemented for improving the stability of the grid during peak load hours. The PV interfaced DC/DC converter and grid interfaced DC/AC bidirectional converter share a DC bus. A smooth transition of one operating mode to another demonstrates the effectiveness of the employed control strategy. Modelling and control of the different components are explained and are implemented in Simulink. Simulations illustrate the feasible behaviour of the charging station under all operating modes in terms of the four-way interaction among PV, EVs and the grid along with V2G operation. Additionally, a business model is discussed with comprehensive analysis of cost estimation for the deployment of charging facilities in a residential area. It has been recognized that EVs bring new opportunities in terms of providing regulation services and consumption flexibility by varying the recharging power at a certain time instant. The paper also discusses the potential financial incentives required to inspire EV owners for active participation in the demand response mechanism.

  3. Operation and maintenance of thermal power stations best practices and health monitoring

    CERN Document Server

    Chanda, Pradip

    2016-01-01

    This book illustrates operation and maintenance practices/guidelines for economic generation and managing health of a thermal power generator beyond its regulatory life. The book provides knowledge for professionals managing power station operations, through its unique approach to chemical analysis of water, steam, oil etc. to identify malfunctioning/defects in equipment/systems much before the physical manifestation of the problem. The book also contains a detailed procedure for conducting performance evaluation tests on different equipment, and for analyzing test results for predicting maintenance requirements, which has lent a new dimension to power systems operation and maintenance practices. A number of real life case studies also enrich the book. This book will prove particularly useful to power systems operations professionals in the developing economies, and also to researchers and students involved in studying power systems operations and control. .

  4. Thermal-hydraulic tests of a recirculation cooling installation for the Rostov nuclear power station

    Science.gov (United States)

    Balunov, B. F.; Balashov, V. A.; Il'in, V. A.; Krayushnikov, V. V.; Lychakov, V. D.; Meshalkin, V. V.; Ustinov, A. N.; Shcheglov, A. A.

    2013-09-01

    Results obtained from thermal-hydraulic tests of the recirculation cooling installation used as part of the air cooling system under the containments of the Rostov nuclear power station Units 3 and 4 are presented. The operating modes of the installation during normal operation (air cooling on the surface of finned tubes), under the conditions of anticipated operational occurrences (air cooling and steam condensation from a steam-air mixture), and during an accident (condensation of pure steam) are considered. Agreement is obtained between the results of tests and calculations carried out according to the recommendations given in the relevant regulatory documents. A procedure of carrying out thermal calculation for the case of steam condensation from a steam-air mixture on the surface of fins is proposed. The possibility of efficient use of the recirculation cooling installation in the system for reducing emergency pressure under the containment of a nuclear power station is demonstrated.

  5. Solar-assisted MED treatment of Eskom power station waste water

    Science.gov (United States)

    Roos, Thomas H.; Rogers, David E. C.; Gericke, Gerhard

    2017-06-01

    The comparative benefits of multi-effect distillation (MED) used in conjunction with Nano Filtration (NF), Reverse Osmosis (RO) and Eutectic Freeze Crystallization (EFC) are determined for waste water minimization for inland coal fired power stations for Zero Liquid Effluent Discharge (ZLED). A sequence of technologies is proposed to achieve maximal water recovery and brine concentration: NF - physico-chemical treatment - MED - EFC. The possibility of extending the concentration of RO reject arising from minewater treatment at the Lethabo power station with MED alone is evaluated with mineral formation modelling using the thermochemical modelling software Phreeq-C. It is shown that pretreatment is essential to extend the amount of water that can be recovered, and this can be beneficially supported by NF.

  6. Magnetic sensing for microstructural assessment of power station steels: Differential permeability and magnetic hysteresis

    Science.gov (United States)

    Karimian, N.; Wilson, J. W.; Yin, W.; Liu, J.; Davis, C. L.; Peyton, A. J.

    2013-06-01

    Failure of power station steel components can have severe economic impacts and also present significant risks to life and the environment. Currently components are inspected during costly shut-downs as no in-situ technique exists to monitor changes in microstructure of in-service steel components. Electromagnetic inspection has the potential to provide information on microstructure changes in power station steels in-situ. In this paper, tests have been carried out on pipe and tube samples in different microstructural conditions, using a lab-based closed magnetic circuit and impedance measurement systems. EM properties have been identified with correlations to material properties, which can quantify degradation in-situ and at elevated temperatures.

  7. Cooling tower restoration in the joint nuclear power station Neckar 1; Kuehlturmsanierung im Gemeinschaftskernkraftwerk Neckar 1

    Energy Technology Data Exchange (ETDEWEB)

    Ernst, G. [Karlsruhe Univ. (T.H.) (Germany). Inst. fuer Technische Thermodynamik; Braeuning, G. [Karlsruhe Univ. (T.H.) (Germany). Inst. fuer Technische Thermodynamik; Dekker, G. [Marley Kuehlturm GmbH, Duesseldorf (Germany). Bereich Vertrieb neuer Kuhlturm-Anlagen

    1996-11-01

    Since the starting operation of the Power Station GKN I (Joint Nuclear Power Station Neckar I) in the year 1976, the cell cooler of the plant was, except for those cases in which continuous-flow cooling was possible, continually in operation. Aim of the restoration, after an operational time of 17 years, is a further constructional and thermal service life of about 15 to 20 years. (orig.) [Deutsch] Seit der Inbetriebnahme des Kraftwerkes GKN I im Jahr 1976 war der Zellenkuehler der Anlage bis auf die Faelle, in denen Durchlaufkuehlung moeglich war, ununterbrochen in Betrieb. Ziel der Sanierung nach ueber 17jaehriger Betriebszeit ist eine weitere bauliche und thermische Nutzungsdauer von etwa 15 bis 20 Jahren. (orig.)

  8. Combined Base Station Association and Power Control in Multi-channel Cellular Networks

    CERN Document Server

    Singh, Chandramani; Sundaresan, Rajesh

    2011-01-01

    A combined base station association and power control problem is studied for the uplink of multichannel multicell cellular networks, in which each channel is used by exactly one cell (i.e., base station). A distributed association and power update algorithm is proposed and shown to converge to a Nash equilibrium of a noncooperative game. We consider network models with discrete mobiles (yielding an atomic congestion game), as well as a continuum of mobiles (yielding a population game). We find that the equilibria need not be Pareto efficient, nor need they be system optimal. To address the lack of system optimality, we propose pricing mechanisms. It is shown that these mechanisms can be implemented in a distributed fashion.

  9. Functions and concept of the process information system for a power station

    Energy Technology Data Exchange (ETDEWEB)

    Woyke, W. [E.ON Energie AG, Neue Technologien, Muenchen (Germany). Regenerative Energieumwandlung

    2001-07-01

    Methods of archiving, evaluation and compression in connection with measured values of the process information system is a link between control system and office application. The applications and tasks, functions and concept of the process information system of a power station will be explained. Practical examples of the introduction of the process information system for a power station of E.ON Kraftwerke GmbH, real applications in the field of process optimization, process analysis and reporting will demonstrate the system. (orig.) [German] Durch Archivierung, Auswertung und Komprimierung von Messwerten schafft das Prozessinformationssystem ein Bindeglied zwischen Leittechnik auf der einen und Office-Anwendungen auf der anderen Seite, Ausgehend von Anwendungen und Aufgaben werden Funktionen und Konzept fuer das Prozessinformationssystem in einem Kraftwerk dargestellt. Anhand von praktischen Beispielen aus der Einfuehrung eines Prozessinformationssystems in einem Kraftwerk der E.ON Kraftwerke GmbH werden konkrete Anwendungen aus dem Bereich von Prozessoptimierung, Prozessanalyse und Berichtswesen mit einem Prozessinformationssystem erlaeutert. (orig.)

  10. Generating power stations and optimization energetic of processes; Centrales generadoras y optimacion energetica de procesos

    Energy Technology Data Exchange (ETDEWEB)

    Gutierrez Ramirez, Ranulfo; Fernandez Montiel, Manuel Francisco [Instituto de Investigaciones Electricas, Temixco, Morelos (Mexico)

    1999-07-01

    Some recent experiences of the Management of Thermal Processes of the Instituto de Investigaciones Electricas (IIE) related to the works on generating power stations of electricity, plants of cogeneration and energy saving are presented. [Spanish] Se presentan algunas experiencias recientes de la Gerencia de Procesos Termicos del Instituto de Investigaciones Electricas (IIE) relacionadas con los trabajos sobre centrales generadoras de electricidad, plantas de cogeneracion y ahorro de energia.

  11. 280 burners reduce NOx emissions and improve boiler performance at Nanticoke power station

    Energy Technology Data Exchange (ETDEWEB)

    Burpee, J.; Tigges, K.-D.; Baehner, J. [Ontario Power Generation, Inc. (Canada)

    1999-07-01

    Describes work undertaken at the Nanticoke coal-fired power station (Canada), to convert the existing burners to low NO{sub x} burners to meet NO{sub x} reduction requirements and improve boiler performance. The burners on four units have already been modified and conversion work is been carried out on three other units. 280 modified coal burners are expected to be in operation by the end of 1999. 17 figs.

  12. Augmentation of coal handling plant for Nasik Thermal Power Station, India

    Energy Technology Data Exchange (ETDEWEB)

    Thakkar, M.C.; Bandhu, K.K.; Vyas, M.R.

    1989-08-01

    The augmentation of the coal handling plant at Nasik Thermal Power Station, India, was necessary, because the volume of coal to be handled increased due to the poor coal quality. The Maharashtra State Electricity Board therefore decided to install an additional conveying system consisting of a rotary-type wagon tippler (car dumper), a three-stage crushing plant, stacking and reclaiming equipment, and a motorized tripper bunkering system. 5 figs., 1 tab.

  13. Toess weir with small power station Pfungen; Toesswehr mit Kleinkraftwerk Pfungen

    Energy Technology Data Exchange (ETDEWEB)

    Haerri, R.W. [Amt fuer Gewaesserschutz und Wasserbau, Abt. Gewaesserkorrektionen, Zurich (Switzerland)

    1995-12-31

    Near Pfungen on the River Toess the Canton of Zurich replaced a dilapidated weir and utilises the available falling gradient with a small power station. Besides the production of renewable energy the assistance of a fish ladder has been made available. (orig.) [Deutsch] Bei Pfungen an der Toess ersetzte der Kanton Zuerich ein baufaelliges Wehr und nutzt das vorhandene Gefaelle mit einem Kleinkraftwerk. Neben der Erzeugung von erneuerbarer Energie kann nun mit Hilfe einer Treppe auch der Fischaufstieg gewaehrleistet werden. (orig.)

  14. [The evaluation of hazardous cinder wastes in Ulan Ude thermal power stations].

    Science.gov (United States)

    Borisenkova, R V; Dik, E P; Soboleva, A N; Lutsenko, L A

    2000-01-01

    Considering possibility of waste materials use in building materials production, the authors evaluated toxicity of ash and clinker waste of electric power stations in Ulan-Ude city. The ash dust and its tincture in water, when injected even in maximal amounts, induced no intoxication symptoms and death in experimental animals, therefore bear no toxicity. Using toxicity indexes to compare ash and clinker waste dust with nontoxic dust proved the studied waste to be nontoxic and acceptable for use in building industry.

  15. [Vegetation distribution in coal cinder yard of Wuhu thermal power station].

    Science.gov (United States)

    Wang, Youbao; Zhang, Li; Liu, Dengyi

    2002-12-01

    There are 30 species of natural colonized plants in the coal cinder yard of Wuhu thermal power station, and they are subordinate to 14 families and 29 genera. The main families are Compositae (7 species), Gramineae (6 species) and Leguminesae, among which, 18 species are annual plant, 9 species are perennial plant, and 2 species are woody plants. The chief factors limiting the vegetation distribution are extreme infertility and high concentration of heavy metals.

  16. Differential permeability behaviour of P9 and T22 power station Steels

    Energy Technology Data Exchange (ETDEWEB)

    Karimian, N., E-mail: Noushin.Karimian@Manchester.ac.uk [School of Electrical and Electronic Engineering, University of Manchester, M60 1QD (United Kingdom); Wilson, J.W.; Peyton, A.J.; Yin, W. [School of Electrical and Electronic Engineering, University of Manchester, M60 1QD (United Kingdom); Liu, J.; Davis, C.L. [School of Metallurgy and Materials, University of Birmingham, Edgbaston, Birmingham B15 2TT (United Kingdom)

    2014-02-15

    Analysis of the electromagnetic (EM) properties of power station steels, measured using a non-contact magnetic sensor, is of significance as such properties are indicative of the microstructure of the material and can be potentially exploited for non-destructive testing. In this paper, we present EM measurements of cylindrical power station steel samples (P9 and T22 grades) with different microstructures: normalised and tempered (representative of the initial condition), as normalised and after service exposure. In order to obtain the magnetic properties the B–H curves of these samples were measured. Cylindrical air-cored and printed circuit board (PCB) coil integrated sensors were used to measure the incremental permeability. Analytical and numerical methods (Finite Elements Methods) were employed to calculate the sensor response of these samples. The electromagnetic properties of the different steels were inferred by fitting the finite element models to the measured results. In addition, sensitivity and error analysis were carried out to evaluate the accuracy of the method. - Highlights: • We analysed the electromagnetic (EM) properties of power station steels. • The B–H curves, differential and incremental permeability were measured. • We established correlations between EM properties and microstructure changes. • This technique will be used to develop a tool for in-situ inspection of steels.

  17. Tampa Electric Company`s Polk Power Station Integrated Gasification Combined Cycle Project

    Energy Technology Data Exchange (ETDEWEB)

    Jenkins, S.D.; Shafer, J.R.

    1994-12-31

    Tampa Electric Company (TEC) is in the construction phase for the new Polk Power Station, Unit {number_sign}1. This will be the first unit at a new site and will use Integrated Gasification Combined Cycle (IGCC) technology for power generation. The unit will utilize oxygen-blown entrained-flow coal gasification, along with combined cycle technology, to provide nominal net 26OMW of generation. As part of the environmental features of this process, the sulfur species in the coal will be recovered as a commercial grade sulfuric acid by-product. The sulfur will be removed from the synthesis gas utilizing a cold gas clean-up system (CGCU).

  18. Life is Short: The Impact of Power States on Base Station Lifetime

    Directory of Open Access Journals (Sweden)

    Luca Chiaraviglio

    2015-12-01

    Full Text Available We study the impact of power state transitions on the lifetime of base stations (BSs in mobile networks. In particular, we propose a model to estimate the lifetime decrease/increase as a consequence of the application of power state changes. The model takes into account both hardware (HW parameters, which depend on the materials used to build the device, and power state parameters, that instead depend on how and when power state transitions take place. More in depth, we consider the impact of different power states when a BS is active, and one sleep mode state when a BS is powered off. When a BS reduces the power consumption, its lifetime tends to increase. However, when a BS changes the power state, its lifetime tends to be decreased. Thus, there is a tradeoff between these two effects. Our results, obtained over universal mobile telecommunication system (UMTS and long term evolution (LTE case studies, indicate the need of a careful management of the power state transitions in order to not deteriorate the BS lifetime, and consequently to not increase the associated reparation/replacement costs.

  19. Feasibility Study of a Solar-Powered Electric Vehicle Charging Station Model

    Directory of Open Access Journals (Sweden)

    Bin Ye

    2015-11-01

    Full Text Available In China, the power sector is currently the largest carbon emitter and the transportation sector is the fastest-growing carbon emitter. This paper proposes a model of solar-powered charging stations for electric vehicles to mitigate problems encountered in China’s renewable energy utilization processes and to cope with the increasing power demand by electric vehicles for the near future. This study applies the proposed model to Shenzhen City to verify its technical and economic feasibility. Modeling results showed that the total net present value of a photovoltaic power charging station that meets the daily electricity demand of 4500 kWh is $3,579,236 and that the cost of energy of the combined energy system is $0.098/kWh. In addition, the photovoltaic powered electric vehicle model has pollutant reduction potentials of 99.8%, 99.7% and 100% for carbon dioxide, sulfur dioxide, and nitrogen oxides, respectively, compared with a traditional gasoline-fueled car. Sensitivity analysis results indicated that interest rate has a relatively strong influence on COE (Cost of Energy. An increase in the interest rate from 0% to 6% increases COE from $0.027/kWh to $0.097/kWh. This analysis also suggests that carbon pricing promotes renewable energy only when the price of carbon is above $20/t.

  20. Computerized training program usage at the Fort Calhoun Nuclear Power Station

    Energy Technology Data Exchange (ETDEWEB)

    Ruzic, D.H.; Reed, W.H.; Lawton, R.K.; Fluehr, J.J.

    1987-01-01

    The increased US Nuclear Regulatory Commission and Institute of Nuclear Power Operations (INPO) interest in the nuclear power industry training programs resulted in the Omaha Public Power District staff at the Fort Calhoun Nuclear Power Station investigating the potential for computerizing their recently accredited training records, student training requirements, and the process of determining student certification status. Additional areas that were desirable were a computerized question data bank with random test generation, maintaining history of question usage, and tracking of the job task analysis process and course objectives. SCI Software's online personnel training information management system (OPTIM) was selected, subsequent to a bid evaluation, to provide these features while operating on the existing corporate IBM mainframe.

  1. Development of low head Kaplan turbine for power station rehabilitation project

    Science.gov (United States)

    Lim, S. M.; Ohtake, N.; Kurosawa, S.; Suzuki, T.; Yamasaki, T.; Nishi, H.

    2012-11-01

    This paper presents the latest Kaplan turbine rehabilitation project for Funagira Power Station in Japan completed by J-POWER Group in collaboration with Toshiba Corporation. Area of rehabilitation was restricted to guide vane and runner. The main goal of the rehabilitation project was to expand the operating range of the existing turbine in terms of discharge and power with high operational stability, low noise as well as high cavitation performance. Computational Fluids Dynamics and model test were used to optimize the shape of guide vane and runner in development stage. Finally, field tests and runner inspection were carried out to confirm the performance of the new turbine. It was found that the new turbine has excellent performance in efficiency, power output, operational stability compared with existing turbine. Moreover, no sign of cavitation on the runner blade surface was observed after 5078 hours of operation near 100% load.

  2. Business Models for Solar Powered Charging Stations to Develop Infrastructure for Electric Vehicles

    Directory of Open Access Journals (Sweden)

    Jessica Robinson

    2014-10-01

    Full Text Available Electric power must become less dependent on fossil fuels and transportation must become more electric to decrease carbon emissions and mitigate climate change. Increasing availability and accessibility of charging stations is predicted to increase purchases of electric vehicles. In order to address the current inadequate charging infrastructure for electric vehicles, major entities must adopt business models for solar powered charging stations (SPCS. These SPCS should be located in parking lots to produce electricity for the grid and provide an integrated infrastructure for charging electric vehicles. Due to the lack of information related to SPCS business models, this manuscript designs several models for major entities including industry, the federal and state government, utilities, universities, and public parking. A literature review of the available relevant business models and case studies of constructed charging stations was completed to support the proposals. In addition, a survey of a university’s students, staff, and faculty was conducted to provide consumer research on people’s opinion of SPCS construction and preference of business model aspects. Results showed that 69% of respondents would be more willing to invest in an electric vehicle if there was sufficient charging station infrastructure at the university. Among many recommendations, the business models suggest installing level 1 charging for the majority of entities, and to match entities’ current pricing structures for station use. The manuscript discusses the impacts of fossil fuel use, and the benefits of electric car and SPCS use, accommodates for the present gap in available literature on SPCS business models, and provides current consumer data for SPCS and the models proposed.

  3. Stability of large DC power systems using switching converters, with application to the international space station

    Science.gov (United States)

    Manners, B.; Gholdston, E. W.; Karimi, K.; Lee, F. C.; Rajagopalan, J.; Panov, Y.

    1996-01-01

    As space direct current (dc) power systems continue to grow in size, switching power converters are playing an ever larger role in power conditioning and control. When designing a large dc system using power converters of this type, special attention must be placed on the electrical stability of the system and of the individual loads on the system. In the design of the electric power system (EPS) of the International Space Station (ISS), the National Aeronautics and Space Administration (NASA) and its contractor team led by Boeing Defense & Space Group has placed a great deal of emphasis on designing for system and load stability. To achieve this goal, the team has expended considerable effort deriving a dear concept on defining system stability in both a general sense and specifically with respect to the space station. The ISS power system presents numerous challenges with respect to system stability, such as high power, complex sources and undefined loads. To complicate these issues, source and load components have been designed in parallel by three major subcontractors (Boeing, Rocketdyne, and McDonnell Douglas) with interfaces to both sources and loads being designed in different countries (Russia, Japan, Canada, Europe, etc.). These issues, coupled with the program goal of limiting costs, have proven a significant challenge to the program. As a result, the program has derived an impedance specification approach for system stability. This approach is based on the significant relationship between source and load impedances and the effect of this relationship on system stability. This approach is limited in its applicability by the theoretical and practical limits on component designs as presented by each system segment. As a result, the overall approach to system stability implemented by the ISS program consists of specific hardware requirements coupled with extensive system analysis and hardware testing. Following this approach, the ISS program plans to begin

  4. Simulations of thermal-hydraulic processes in heat exchangers- station of the cogeneration power plant

    Energy Technology Data Exchange (ETDEWEB)

    Studovic, M.; Stevanovic, V.; Ilic, M.; Nedeljkovic, S. [Faculty of Mechanical Engineering of Belgrade (Croatia)

    1995-12-31

    Design of the long district heating system to Belgrade (base load 580 MJ/s) from Thermal Power Station `Nikola Tesla A`, 30 km southwest from the present gas/oil burning boilers in New Belgrade, is being conducted. The mathematical model and computer code named TRP are developed for the prediction of the design basis parameters of heat exchangers station, as well as for selection of protection devices and formulation of operating procedures. Numerical simulations of heat exchangers station are performed for various transient conditions: up-set and abnormal. Physical model of multi-pass, shell and tube heat exchanger in the station represented is by unique steam volume, and with space discretised nodes both for water volume and tube walls. Heat transfer regimes on steam and water side, as well as hydraulic calculation were performed in accordance with TEMA standards for transient conditions on both sides, and for each node on water side. Mathematical model is based on balance equations: mass and energy for lumped parameters on steam side, and energy balances for tube walls and water in each node. Water mass balance is taken as boundary/initial condition or as specified control function. The physical model is proposed for (s) heat exchangers in the station and (n) water and wall volumes. Therefore, the mathematical model consists of 2ns+2, non-linear differential equations, including equations of state for water, steam and tube material, and constitutive equations for heat transfer on steam and water side, solved by the Runge-Kutt method. Five scenarios of heat exchangers station behavior have been simulated with the TRP code and obtained results are presented. (author)

  5. Berkeley-Madonna implementation of Ikeda's model.

    Science.gov (United States)

    Fontecave-Jallon, J; Baconnier, P

    2007-01-01

    Starting from one model, we check the possibility of using Berkeley-Madonna software to transpose and simulate some existing biological integrated models. The considered model is the one of Ikeda et al., proposed in 1979, which treats of fluid regulation and which is very well described mathematically in the original paper. Despite a few mistakes or bugs, the model has been easily and successfully implemented under Berkeley-Madonna. We recover the same simulation results as Ikeda and new simulations can now easily be carried out, thanks to the user-friendly qualities of Berkeley-Madonna.

  6. Analysis of the Use of Wind Energy to Supplement the Power Needs at McMurdo Station and Amundsen-Scott South Pole Station, Antarctica

    Energy Technology Data Exchange (ETDEWEB)

    Baring-Gould, I.; Robichaud, R.; McLain, K.

    2005-05-01

    This report summarizes an analysis of the inclusion of wind-driven power generation technology into the existing diesel power plants at two U.S. Antarctic research stations, McMurdo and Amundsen-Scott South Pole Station. Staff at the U.S. Department of Energy's National Renewable Energy Laboratory (NREL) conducted the analysis. Raytheon Polar Services, which currently holds the private sector support contract for the two research stations, was a major contributor to this report. To conduct the analysis, available data were obtained on the wind resources, power plant conditions, load, and component cost. Whenever possible, we validated the information. We then used NREL's Hybrid2 power system modeling software to analyze the potential and cost of using wind turbine generators at the two aforementioned facilities. Unfortunately, the power systems and energy allocations at McMurdo and South Pole Station are being redeveloped, so it is not possible to validate future fuel use. This report is an initial assessment of the potential use of wind energy and should be followed by further, more detailed analysis if this option is to be considered further.

  7. The anticentre old open clusters Berkeley 27, Berkeley 34, and Berkeley 36: new additions to the BOCCE project

    CERN Document Server

    Donati, P; Cignoni, M; Cocozza, G; Tosi, M

    2012-01-01

    In this paper we present the investigation of the evolutionary status of three open clusters: Berkeley 27, Berkeley 34, and Berkeley 36, all located in the Galactic anti-centre direction. All of them were observed with SUSI2@NTT using the Bessel B, V, and I filters. The cluster parameters have been obtained using the synthetic colour-magnitude diagram (CMD) method i.e. the direct comparison of the observational CMDs with a library of synthetic CMDs generated with different evolutionary sets (Padova, FRANEC, and FST). This analysis shows that Berkeley 27 has an age between 1.5 and 1.7 Gyr, a reddening E(B-V) in the range 0.40 and 0.50, and a distance modulus (m-M)_0 between 13.1 and 13.3; Berkeley 34 is older with an age in the range 2.1 and 2.5 Gyr, E(B-V) between 0.57 and 0.64, and (m-M)_0 between 14.1 and 14.3; Berkeley 36, with an age between 7.0 and 7.5 Gyr, has a reddening E(B-V)~0.50 and a distance modulus (m-M)_0 between 13.1 and 13.2. For all the clusters our analysis suggests a sub-solar metallicity ...

  8. The potential impact of new power system technology on the design of a manned Space Station

    Science.gov (United States)

    Fordyce, J. S.; Schwartz, H. J.

    1984-01-01

    Larger, more complex spacecraft of the future such as a manned Space Station will require electric power systems of 100 kW and more, orders of magnitude greater than the present state of the art. Power systems at this level will have a significant impact on the spacecraft design. Historically, long-lived spacecraft have relied on silicon solar cell arrays, a nickel-cadmium storage battery and operation at 28 V dc. These technologies lead to large array areas and heavy batteries for a Space Station application. This, in turn, presents orbit altitude maintenance, attitude control, energy management and launch weight and volume constraints. Size (area) and weight of such a power system can be reduced if new higher efficiency conversion and lighter weight storage technologies are used. Several promising technology options including concentrator solar photovoltaic arrays, solar thermal dynamic and ultimately nuclear dynamic systems to reduce area are discussed. Also, higher energy storage systems such as nickel-hydrogen and the regenerative fuel cell (RFC) and higher voltage power distribution which add system flexibility, simplicity and reduce weight are examined. Emphasis placed on the attributes and development status of emerging technologies that are sufficiently developed so that they could be available for flight use in the early to mid 1990's.

  9. Comparison and evaluation of nuclear power plant options for geosynchronous power stations

    Science.gov (United States)

    Williams, J. R.

    1975-01-01

    The suitability of eleven types of nuclear fission reactors in combination with five potential energy conversion systems for use in geosynchronous power plants is evaluated. Gas turbine, potassium Rankine liquid metal MHD, and thermionic energy conversion systems are considered. The existing technology of reactors in near-term, intermediate-term, and long-term classes is discussed, together with modifications for use in large-scale power production in space. Unless the temperature is high enough for MHD, reactors which heat gases are generally more suitable for use with gas turbines. Those which heat liquid metals will be more useful for potassium Rankine or liquid metal MHD conversion systems.

  10. Berkeley Lab Laser Accelerator (BELLA) facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Berkeley Lab Laser Accelerator (BELLA) facility (formerly LOASIS) develops advanced accelerators and radiation sources. High gradient (1-100 GV/m) laser-plasma...

  11. Program for the thermal design and simulation of the operation of a steam condenser for thermal and nuclear power stations and its application to the condenser at the Cofrentes nuclear power station

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Bartual, R.; Pallares Huici, E.

    A program is being developed for an IBM-PC or AT computer based on a calculation system which synthesises the heat transfer process which takes place in the steam condensors at conventional thermal power stations. The program incorporates a useful tool capable of representing characteristic operating curves for a given condensor. Describes its application to the steam condenser at the Cofrentes nuclear power station. 4 refs., 5 tabs., 8 figs.

  12. Research on H2 speed governor for diesel engine of marine power station

    Institute of Scientific and Technical Information of China (English)

    HUANG Man-lei

    2007-01-01

    The frequency stability of a marine power system is determined by the dynamic characteristic of the diesel engine speed regulation system in a marine power station. In order to reduce the effect of load disturbances and improve the dynamic precision of a diesel engine speed governor, a controller was designed for a diesel engine speed regulation system using H2 control theory. This transforms the specifications of the system into a standard H2 control problem. Firstly, the mathematical model of a diesel engine speed regulation system using an H2 speed governor is presented. To counter external disturbances and model uncertainty, the design of an H2 speed governor rests on the problem of mixed sensitivity. Computer simulation verified that the H2 speed governor improves the dynamic precision of a system and the ability to adapt to load disturbances, thus enhancing the frequency stability of marine power systems.

  13. Seismic margin review of the Maine Yankee Atomic Power Station: Fragility analysis

    Energy Technology Data Exchange (ETDEWEB)

    Ravindra, M. K.; Hardy, G. S.; Hashimoto, P. S.; Griffin, M. J.

    1987-03-01

    This Fragility Analysis is the third of three volumes for the Seismic Margin Review of the Maine Yankee Atomic Power Station. Volume 1 is the Summary Report of the first trial seismic margin review. Volume 2, Systems Analysis, documents the results of the systems screening for the review. The three volumes are part of the Seismic Margins Program initiated in 1984 by the Nuclear Regulatory Commission (NRC) to quantify seismic margins at nuclear power plants. The overall objectives of the trial review are to assess the seismic margins of a particular pressurized water reactor, and to test the adequacy of this review approach, quantification techniques, and guidelines for performing the review. Results from the trial review will be used to revise the seismic margin methodology and guidelines so that the NRC and industry can readily apply them to assess the inherent quantitative seismic capacity of nuclear power plants.

  14. In-orbit assembly mission for the Space Solar Power Station

    Science.gov (United States)

    Cheng, ZhengAi; Hou, Xinbin; Zhang, Xinghua; Zhou, Lu; Guo, Jifeng; Song, Chunlin

    2016-12-01

    The Space Solar Power Station (SSPS) is a large spacecraft that utilizes solar power in space to supply power to an electric grid on Earth. A large symmetrical integrated concept has been proposed by the China Academy of Space Technology (CAST). Considering its large scale, the SSPS requires a modular design and unitized general interfaces that would be assembled in orbit. Facilities system supporting assembly procedures, which include a Reusable Heavy Lift Launch Vehicle, orbital transfer and space robots, is introduced. An integrated assembly scheme utilizing space robots to realize this platform SSPS concept is presented. This paper tried to give a preliminary discussion about the minimized time and energy cost of the assembly mission under best sequence and route This optimized assembly mission planning allows the SSPS to be built in orbit rapidly, effectively and reliably.

  15. Year Round Operation of Autonomous, Low Power Geophysical Stations in Antarctica

    Science.gov (United States)

    Beaudoin, B. C.; White, S.; Bonnett, B.; Parker, T.; Johns, B.; Anderson, K. R.

    2009-12-01

    Year round operation of autonomous, low power geophysical stations in Antarctica presents both technical and logistical challenges. Prior to 2005, few if any autonomous seismic or GPS stations operated continuously throughout the austral winter. There are two basic environmental challenges in Antarctica beyond the logistical challenge: the margins with relatively mild temperatures but extreme winds and the Polar Plateau with extreme temperatures but relatively little wind. Large caches of lead-acid batteries can operate stations on the Antarctic margins where temperatures are relatively high, but are logistically expensive and will not survive the extreme temperatures of the Polar Plateau. Primary lithium thionyl chloride batteries have been proven to be successful and economical for use in the extreme plateau environment. These technical and logistical challenges were the focus of an IRIS/PASSCAL-UNAVCO collaboration to design power and communications for a < 5W system capable of continuous operation without intervention for two years. This collaboration has resulted in the successful operation of close to 100 GPS and seismic stations on several IPY projects with better than 80% data return. Our systems were designed to challenging logistical constrains for increased efficiency in polar operations. These year-round systems can now be deployed in a single twin otter flight. The IRIS/PASSCAL-UNAVCO collaboration has resulted in deployable systems backed by facilities with proven track records of longevity of technical field support. Our expertise and sustained engineering has resulted in a robust community product. We have significantly lowered the barriers of entry to scientists who desire year-round autonomous data collection in the Polar regions. A transparent development process with broad community support and input has resulted in a new generation of GPS and seismic systems fielded on several major IPY projects. The challenge now is how to keep the development

  16. Electric Power Plants and Generation Stations, Published in 1992, 1:1200 (1in=100ft) scale, County of Lexington.

    Data.gov (United States)

    NSGIC GIS Inventory (aka Ramona) — This Electric Power Plants and Generation Stations dataset, published at 1:1200 (1in=100ft) scale, was produced all or in part from Orthoimagery information as of...

  17. Intermediate photovoltaic system application experiment operational performance report. Volume 13. For Newman Power Station, El Paso, Texas

    Energy Technology Data Exchange (ETDEWEB)

    1982-09-01

    Presented are the data accumulated during June at the intermediate photovoltaic project at Newman Power Station, El Paso, Texas. Generated energy and environmental (weather) data are presented graphically. Explanations of irregularities not attributable to weather are provided.

  18. 78 FR 11904 - Zion Nuclear Power Station, Units 1 and 2; ZionSolutions, LLC; Consideration of Indirect Transfer

    Science.gov (United States)

    2013-02-20

    ... From the Federal Register Online via the Government Publishing Office NUCLEAR REGULATORY COMMISSION Zion Nuclear Power Station, Units 1 and 2; ZionSolutions, LLC; Consideration of Indirect Transfer AGENCY: Nuclear Regulatory Commission. ACTION: Request for license transfer; opportunity to...

  19. 75 FR 7628 - Davis-Besse Nuclear Power Station; Notice of Consideration of Issuance of Amendment to Facility...

    Science.gov (United States)

    2010-02-22

    ... COMMISSION Davis-Besse Nuclear Power Station; Notice of Consideration of Issuance of Amendment to Facility Operating License, Proposed No Significant Hazards Consideration Determination, and Opportunity for a... determination that the amendment request involves no significant hazards consideration. Under the...

  20. Methane Emissions from Permafrost Regions using Low-Power Eddy Covariance Stations

    Science.gov (United States)

    Burba, G.; Sturtevant, C.; Schreiber, P.; Peltola, O.; Zulueta, R.; Mammarella, I.; Haapanala, S.; Rinne, J.; Vesala, T.; McDermitt, D.; Oechel, W.

    2012-04-01

    result, spatial coverage of eddy covariance methane flux measurements remains limited. Remote permafrost wetlands of Arctic tundra, northern boreal peatlands of Canada and Siberia, and other highly methanogenic ecosystems have few eddy covariance methane measurement stations. Those existing are often located near grid power sources and roads rather than in the middle of the methane-producing ecosystem, while those that are placed appropriately may require extraordinary efforts to build and maintain them, with large investments into man-power and infrastructure. Alternatively, open-path approach allows methane flux measurements at ambient pressure without the need for a pump. As a result, the measurements can be done with very low-power (e.g. 5-10 Watts), light (5 .2 kg) instruments permitting solar- and wind- powered remote deployments in hard-to-reach sites from permanent, portable or mobile stations, and cost-effective additions of a methane measurement to the present array of CO2 and H2O measurements. The low-power operation and light weight of open-path eddy covariance stations is important for a number of ecosystems (rice fields, landfills, wetlands, cattle yards), but it is especially important for permafrost regions where grid power and access roads are generally not available, and the logistics of running the experiments are particularly expensive. Emerging research on methane flux measurements using low-power stations equipped with LI-7700 open-path methane analyzer (LI-COR Biosciences) are presented from several permafrost ecosystems with contrasting setups, and weather conditions. Principles of operation, station characteristics and requirements are also discussed.

  1. Reliability measurement for mixed mode failures of 33/11 kilovolt electric power distribution stations.

    Directory of Open Access Journals (Sweden)

    Faris M Alwan

    Full Text Available The reliability of the electrical distribution system is a contemporary research field due to diverse applications of electricity in everyday life and diverse industries. However a few research papers exist in literature. This paper proposes a methodology for assessing the reliability of 33/11 Kilovolt high-power stations based on average time between failures. The objective of this paper is to find the optimal fit for the failure data via time between failures. We determine the parameter estimation for all components of the station. We also estimate the reliability value of each component and the reliability value of the system as a whole. The best fitting distribution for the time between failures is a three parameter Dagum distribution with a scale parameter [Formula: see text] and shape parameters [Formula: see text] and [Formula: see text]. Our analysis reveals that the reliability value decreased by 38.2% in each 30 days. We believe that the current paper is the first to address this issue and its analysis. Thus, the results obtained in this research reflect its originality. We also suggest the practicality of using these results for power systems for both the maintenance of power systems models and preventive maintenance models.

  2. Morbidity Profile of Employees Working in a Thermal Power Station Parali

    Directory of Open Access Journals (Sweden)

    U G Kawalkar; V A Kakrani; A S Nagaonkar; V L Vedpathak; P L Dahire; P G Kogade

    2014-01-01

    Full Text Available Introduction: Health is multi factorial. An individual’s biological makeup influences health through interaction with social and physical environments as well as behavior. In Thermal power station different groups of employees are exposed to different working conditions and environmental factors at their work place; so an attempt has been made to conduct a study on the morbid conditions in employees of Thermal power station. Material and Method: Cross- sectional descriptive study was done. Total 400 employees were studied. History taking included personal and socio-demographic details occupational history, presenting complaints, past history, family history and history of accidents. Interview was followed by thorough clinical examination. Result: Majority of employees worked in Coal Handling Plant 90(22.5%. Respiratory system morbidities were maximum i.e. chronic bronchitis in 53 (13.25% study subjects. Digestive system morbidities were observed in the form of acid peptic disease in 39 (9.75% employees. Morbidities of circulatory system were hypertension was diagnosed in 55 (13.75% study subjects. Under musculoskeletal system, common morbidities present were back pain i.e. in 22 (5.50%, followed by arthritis in 19 (4.75%. Respiratory morbidity viz. chronic bronchitis and bronchial asthma was most common morbidity. Conclusion: For employee working in a power plant, it is highly advised that they must have regular health checkups.

  3. Performance Analyses of Renewable and Fuel Power Supply Systems for Different Base Station Sites

    Directory of Open Access Journals (Sweden)

    Josip Lorincz

    2014-11-01

    Full Text Available Base station sites (BSSs powered with renewable energy sources have gained the attention of cellular operators during the last few years. This is because such “green” BSSs impose significant reductions in the operational expenditures (OPEX of telecom operators due to the possibility of on-site renewable energy harvesting. In this paper, the green BSSs power supply system parameters detected through remote and centralized real time sensing are presented. An implemented sensing system based on a wireless sensor network enables reliable collection and post-processing analyses of many parameters, such as: total charging/discharging current of power supply system, battery voltage and temperature, wind speed, etc. As an example, yearly sensing results for three different BSS configurations powered by solar and/or wind energy are discussed in terms of renewable energy supply (RES system performance. In the case of powering those BSS with standalone systems based on a fuel generator, the fuel consumption models expressing interdependence among the generator load and fuel consumption are proposed. This has allowed energy-efficiency comparison of the fuel powered and RES systems, which is presented in terms of the OPEX and carbon dioxide (CO2 reductions. Additionally, approaches based on different BSS air-conditioning systems and the on/off regulation of a daily fuel generator activity are proposed and validated in terms of energy and capital expenditure (CAPEX savings.

  4. Semi-quantitative characterisation of ambient ultrafine aerosols resulting from emissions of coal fired power stations.

    Science.gov (United States)

    Hinkley, J T; Bridgman, H A; Buhre, B J P; Gupta, R P; Nelson, P F; Wall, T F

    2008-02-25

    Emissions from coal fired power stations are known to be a significant anthropogenic source of fine atmospheric particles, both through direct primary emissions and secondary formation of sulfate and nitrate from emissions of gaseous precursors. However, there is relatively little information available in the literature regarding the contribution emissions make to the ambient aerosol, particularly in the ultrafine size range. In this study, the contribution of emissions to particles smaller than 0.3 mum in the ambient aerosol was examined at a sampling site 7 km from two large Australian coal fired power stations equipped with fabric filters. A novel approach was employed using conditional sampling based on sulfur dioxide (SO(2)) as an indicator species, and a relatively new sampler, the TSI Nanometer Aerosol Sampler. Samples were collected on transmission electron microscope (TEM) grids and examined using a combination of TEM imaging and energy dispersive X-ray (EDX) analysis for qualitative chemical analysis. The ultrafine aerosol in low SO(2) conditions was dominated by diesel soot from vehicle emissions, while significant quantities of particles, which were unstable under the electron beam, were observed in the high SO(2) samples. The behaviour of these particles was consistent with literature accounts of sulfate and nitrate species, believed to have been derived from precursor emissions from the power stations. A significant carbon peak was noted in the residues from the evaporated particles, suggesting that some secondary organic aerosol formation may also have been catalysed by these acid seed particles. No primary particulate material was observed in the minus 0.3 mum fraction. The results of this study indicate the contribution of species more commonly associated with gas to particle conversion may be more significant than expected, even close to source.

  5. Electric Power Plants and Generation Stations, Power_plants, Published in 2007, 1:600 (1in=50ft) scale, Buffalo County.

    Data.gov (United States)

    NSGIC GIS Inventory (aka Ramona) — This Electric Power Plants and Generation Stations dataset, published at 1:600 (1in=50ft) scale, was produced all or in part from Orthoimagery information as of...

  6. Radioactivity level of the ambient environment of Anren bone-coal power station

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    The radioactivity level of the ambient environment of Anren Bonc-coalPower Station (BCPS) was investigated systematically. The γ radiation dose ratelevel in the environment, the content of 238U and 226Ra in the ambient soil and thefarmland in the direction of downwind, the concentrations of 238U, 232Th, 226Ra, 40Kand 222Rn, as well as α potential energy in air, and the concentrations of natural Uand Th in effluent are all higher than the corresponding values of the reference site.The additional annual effective dose equivalent to the residents living in the housesmade of bone-coal cinder brick is 2.7mSv.

  7. PID Controller Parameters Tuning Based-on Satisfaction for Superheated Steam Temperature of Power Station Boiler

    Directory of Open Access Journals (Sweden)

    Benxian Xiao

    2014-06-01

    Full Text Available Proposed the PID controller parameters tuning method based-on New Luus-Jaakola (NLJ algorithm and satisfaction idea. According to the different requirements of each performance index, designed the satisfaction function with fuzzy constraint attributes, and then determined the comprehensive satisfaction function for PID tuning by NLJ algorithm. Provided the steps of PID controller parameters tuning based on the NLJ algorithm and satisfaction, and applied this tuning method to the cascade control system of superheated steam temperature for Power Station Boiler. Finally the simulation and experiment results have shown the proposed method has good dynamic and static control performances for this complicated superheated steam temperature control system.

  8. Safety research of insulating materials of cable for nuclear power generating station

    Science.gov (United States)

    Lee, C. K.; Choi, J. H.; Kong, Y. K.; Chang, H. S.

    1988-01-01

    The polymers PE, EPR, PVC, Neoprene, CSP, CLPE, EP and other similar substances are frequently used as insulation and protective covering for cables used in nuclear power generating stations. In order to test these materials for flame retardation, environmental resistance, and cable specifications, they were given the cable normal test, flame test, chemical tests, and subjected to design analysis and loss of coolant accident tests. Material was collected on spark tests and actual experience standards were established through these contributions and technology was accumulated.

  9. TOF SIMS Study on PAHs in Individual Particle from a Power Station

    Institute of Scientific and Technical Information of China (English)

    梁汉东; 于春海; 周强; 李艳芳

    2001-01-01

    The individual particles collected from a power station were analyzed by time of flight secondary ion mass spectrometry (TOF SIMS). The result indicates the presence of the polycyclic aromatic hydrocarbon (PAHs) as well as the oxygenated one. They might be derived from the incomplete combustion of coals. SIMS has proved to be a rapid method for the qualitative analysis of PAHs and OPAHs absorbed on the aerosol particles. New perspectives for better understanding the SIMS spectra obtained from complex mixture such as environmental samples have been opened.

  10. Modern power station practice mechanical boilers, fuel-, and ash-handling plant

    CERN Document Server

    Sherry, A; Cruddace, AE

    2014-01-01

    Modern Power Station Practice, Second Edition, Volume 2: Mechanical (Boilers, Fuel-, and Ash-Handling Plant) focuses on the design, manufacture and operation of boiler units and fuel-and ash-handling plants.This book is organized into five main topics-furnace and combustion equipment, steam and water circuits, ancillary plant and fittings, dust extraction and draught plant, and fuel-and ash-handling plant.In these topics, this text specifically discusses the influence of nature of coal on choice of firing equipment; oil-burner arrangements, ignition and control; disposition of the heating surf

  11. Vapor Online Monitor Model of Vapor Power Station Based on UML

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    We presents a vapor online monitor system model of vapor power station developed by visual tool rational rose2000. Use cases such as on line instrument (onlineinstr), control, query, report, real database (realdb) and alarm are generated according to the system requirements. Use case view and class view of the system are formed at the same time. As for all the UML models of the system, this paper focuses the discussion on the class view, the component diagram of the control class and the sequence diagram of the query class. Corresponding C++ codes are produced and finally transferred into the spot running software.

  12. Study of variations of radiofrequency power density from mobile phone base stations with distance.

    Science.gov (United States)

    Ayinmode, B O; Farai, I P

    2013-10-01

    The variations of radiofrequency (RF) radiation power density with distance around some mobile phone base stations (BTSs), in ten randomly selected locations in Ibadan, western Nigeria, were studied. Measurements were made with a calibrated hand-held spectrum analyser. The maximum Global System of Mobile (GSM) communication 1800 signal power density was 323.91 µW m(-2) at 250 m radius of a BTS and that of GSM 900 was 1119.00 µW m(-2) at 200 m radius of another BTS. The estimated total maximum power density was 2972.00 µW m(-2) at 50 m radius of a different BTS. This study shows that the maximum carrier signal power density and the total maximum power density from a BTS may be observed averagely at 200 and 50 m of its radius, respectively. The result of this study demonstrates that exposure of people to RF radiation from phone BTSs in Ibadan city is far less than the recommended limits by International scientific bodies.

  13. Modeling of interior noise levels in large combustion turbine power stations

    Energy Technology Data Exchange (ETDEWEB)

    Hedeen, R.A. [GE Global Research, Niskayuna, NY (United States); Loud, R.L. [GE Energy, Schenectady, NY (United States)

    2007-07-01

    A study was conducted to predict noise emissions from power generating stations. In particular, the SoundPLAN4 ray-tracing program originally designed for exterior environmental noise propagation analysis, was used to predict the sound levels coming from inside combustion turbines and combined-cycle power plants. Although exterior sound levels are of interest due to their propagation into nearby communities, interior sound levels are important because of their influence on occupational noise exposure. Most regulations are concerned with an 85 dBA, 8 hour exposure. Therefore, plant designers, operators, and owners must be able to predict and control the areas in their plants where these regulations must be considered. In this study, the Raynoise 5 program was also used to analyze sound propagation. The ray-trace model considered the known sound power levels of the major pieces of equipment and was able to predict the sound distribution through the turbine hall with acceptable accuracy. The models used in this study were suitable for both compliance evaluation and noise target optimization of the individual power train components. It was concluded that the location and arrangement of the power train, off-base skids, and stand-alone equipment can be altered to control the sound level in desired areas of the plant. 7 refs., 4 figs.

  14. Optimization Study of Shaft Tubular Turbine in a Bidirectional Tidal Power Station

    Directory of Open Access Journals (Sweden)

    Xinfeng Ge

    2013-01-01

    Full Text Available The shaft tubular turbine is a form of tidal power station which can provide bidirectional power. Efficiency is an important turbine performance indicator. To study the influence of runner design parameters on efficiency, a complete 3D flow-channel model of a shaft tubular turbine was developed, which contains the turbine runner, guide vanes, and flow passage and was integrated with hybrid grids calculated by steady-state calculation methods. Three aspects of the core component (turbine runner were optimized by numerical simulation. All the results were then verified by experiments. It was shown that curved-edge blades are much better than straight-edge blades; the optimal blade twist angle is 7°, and the optimal distance between the runner and the blades is 0.75–1.25 times the diameter of the runner. Moreover, the numerical simulation results matched the experimental data very well, which also verified the correctness of the optimal results.

  15. Reliability Analysis of a 3-Machine Power Station Using State Space Approach

    Directory of Open Access Journals (Sweden)

    WasiuAkande Ahmed

    2014-07-01

    Full Text Available With the advent of high-integrity fault-tolerant systems, the ability to account for repairs of partially failed (but still operational systems become increasingly important. This paper presents a systemic method of determining the reliability of a 3-machine electric power station, taking into consideration the failure rates and repair rates of the individual component (machine that make up the system. A state-space transition process for a 3-machine with 23 states was developed and consequently, steady state equations were generated based on Markov mathematical modeling of the power station. Important reliability components were deduced from this analysis. This research simulation was achieved with codes written in Excel® -VBA programming environment. System reliability using state space approach proofs to be a viable and efficient technique of reliability prediction as it is able to predict the state of the system under consideration. For the purpose of neatness and easy entry of data, Graphic User Interface (GUI was designed.

  16. The EURISOL Multi Megawatt Target Station, a liquid metal target for a High Power spallation source.

    CERN Document Server

    Kharoua, C; Blumenfeld, L; Milenkovich, R; Wagner, W; Thomsen, K; Dementjevs, S; Platacis, E; Kravalis, K; Zik, A

    The European Isotope Separation On-Line Radioactive Ion Beam Facility (EURISOL) is set to be the ‘next-generation’ European Isotope Separation On-Line (ISOL) Radioactive Ion Beam (RIB) facility. It will extend and amplify current research in nuclear physics, nuclear astrophysics and fundamental interactions beyond the year 2013.In EURISOL, four target stations are foreseen, three direct targets of approximately 100 kW of beam power and one multi-MW liquid metal proton-to-neutron converter, all driven by a high-power particle accelerator. In the aforementioned multi-MW target assembly, high-intensity RIBs of neutron-rich isotopes will be obtained by inducing fission in several actinide targets surrounding a liquid metal spallation neutron source.This presentation summarises the work carried out for the Multi Megawatt target station of the EURISOL Design Study with particular attention to the coupled neutronic of the liquid converter and the overall performance of the facility, which will sustain fast neutr...

  17. Lichens as biomonitors around a coal-fired power station in Israel

    Energy Technology Data Exchange (ETDEWEB)

    Garty, J.; Tomer, S.; Levin, T.; Lehr, H. [Tel Aviv University, Tel Aviv (Israel). Dept. of Plant Science

    2003-03-01

    In the present study epiphytic lichens were applied as biomonitors of air pollution to determine the environmental impact of a coal-fired power station. Thalli of the lichen Ramalina lacera (With.) J.R. Laund. growing on carob twigs (Ceratonia siliqua L.) were collected with their substrate in July 2000 in a relatively unpolluted forest near HaZorea, Ramoth Menashe, Northeast Israel, and transplanted to 10 biomonitoring sites in the vicinity of the coal-fired power station Oroth Rabin near the town of Hadera. The lichens were retrieved in January 2001. The following parameters of lichen vitality were examined: (a) potential quantum yield of photosynthesis expressed as fluorescence ratio F{sub v}/F{sub m}, (b) stress-ethylene production, and (c) electric conductivity expressing integrity of cell membranes. Following an exposure of 7 months, the lichens were retrieved and physiological parameters and data of elemental content were analyzed comparatively. Electric conductivity values correlated positively with B, Fe, Mg, Mn, Na, Pb, S, Sn, and Ti content. Concentrations of stress-ethylene correlated positively with Al, Ba, Pb, S, and V content and negatively with Cu and Sn. F{sub v}/F{sub m} ratios correlated negatively with S content. Some of the heavy metals reached lower levels than those reported in the relevant literature despite a wind regime that should have blown pollutants toward the biomonitoring sites.

  18. Pressure-dependent fragilities for piping components: Pilot study on Davis-Besse Nuclear Power Station

    Energy Technology Data Exchange (ETDEWEB)

    Wesley, D.A.; Nakaki, D.K.; Hadidi-Tamjed, H. (ABB Impell Corp., Mission Viejo, CA (USA)); Kipp, T.R. (EQE, Inc., Costa Mesa, CA (USA))

    1990-10-01

    The capacities of four, low-pressure fluid systems to withstand pressures and temperatures above the design levels were established for the Davis-Besse Nuclear Power Station. The results will be used in evaluating the probability of plant damage from Interfacing System Loss of Coolant Accidents (ISLOCA) as part of the probabilistic risk assessment of the Davis-Besse nuclear power station undertaken by EG G Idaho, Inc. Included in this evaluation are the tanks, heat exchangers, filters, pumps, valves, and flanged connections for each system. The probabilities of failure, as a function of internal pressure, are evaluated as well as the variabilities associated with them. Leak rates or leak areas are estimated for the controlling modes of failure. The pressure capacities for the pipes and vessels are evaluated using limit-state analyses for the various failure modes considered. The capacities are dependent on several factors, including the material properties, modeling assumptions, and the postulated failure criteria. The failure modes for gasketed-flange connections, valves, and pumps do not lend themselves to evaluation by conventional structural mechanics techniques and evaluation must rely primarily on the results from ongoing gasket research test programs and available vendor information and test data. 21 refs., 7 figs., 52 tabs.

  19. A modernized high-pressure heater protection system for nuclear and thermal power stations

    Science.gov (United States)

    Svyatkin, F. A.; Trifonov, N. N.; Ukhanova, M. G.; Tren'kin, V. B.; Koltunov, V. A.; Borovkov, A. I.; Klyavin, O. I.

    2013-09-01

    Experience gained from operation of high-pressure heaters and their protection systems serving to exclude ingress of water into the turbine is analyzed. A formula for determining the time for which the high-pressure heater shell steam space is filled when a rupture of tubes in it occurs is analyzed, and conclusions regarding the high-pressure heater design most advisable from this point of view are drawn. A typical structure of protection from increase of water level in the shell of high-pressure heaters used in domestically produced turbines for thermal and nuclear power stations is described, and examples illustrating this structure are given. Shortcomings of components used in the existing protection systems that may lead to an accident at the power station are considered. A modernized protection system intended to exclude the above-mentioned shortcomings was developed at the NPO Central Boiler-Turbine Institute and ZioMAR Engineering Company, and the design solutions used in this system are described. A mathematical model of the protection system's main elements (the admission and check valves) has been developed with participation of specialists from the St. Petersburg Polytechnic University, and a numerical investigation of these elements is carried out. The design version of surge tanks developed by specialists of the Central Boiler-Turbine Institute for excluding false operation of the high-pressure heater protection system is proposed.

  20. Lichens as biomonitors around a coal-fired power station in Israel.

    Science.gov (United States)

    Garty, Jacob; Tomer, Sharon; Levin, Tal; Lehr, Haya

    2003-03-01

    In the present study epiphytic lichens were applied as biomonitors of air pollution to determine the environmental impact of a coal-fired power station. Thalli of the lichen Ramalina lacera (With.) J.R. Laund. growing on carob twigs (Ceratonia siliqua L.) were collected with their substrate in July 2000 in a relatively unpolluted forest near HaZorea, Ramoth Menashe, Northeast Israel, and transplanted to 10 biomonitoring sites in the vicinity of the coal-fired power station Oroth Rabin near the town of Hadera. The lichens were retrieved in January 2001. We examined the following parameters of lichen vitality: (a) potential quantum yield of photosynthesis expressed as fluorescence ratio F(v)/F(m), (b) stress-ethylene production, and (c) electric conductivity expressing integrity of cell membranes. Following an exposure of 7 months, the lichens were retrieved and physiological parameters and data of elemental content were analyzed comparatively. Electric conductivity values correlated positively with B, Fe, Mg, Mn, Na, Pb, S, Sn, and Ti content. Concentrations of stress-ethylene correlated positively with Al, Ba, Pb, S, and V content and negatively with Cu and Sn. F(v)/F(m) ratios correlated negatively with S content. Some of the heavy metals reached lower levels than those reported in the relevant literature despite a wind regime that should have blown pollutants toward the biomonitoring sites.

  1. Differential permeability behaviour of P9 and T22 power station Steels

    Science.gov (United States)

    Karimian, N.; Wilson, J. W.; Peyton, A. J.; Yin, W.; Liu, J.; Davis, C. L.

    2014-02-01

    Analysis of the electromagnetic (EM) properties of power station steels, measured using a non-contact magnetic sensor, is of significance as such properties are indicative of the microstructure of the material and can be potentially exploited for non-destructive testing. In this paper, we present EM measurements of cylindrical power station steel samples (P9 and T22 grades) with different microstructures: normalised and tempered (representative of the initial condition), as normalised and after service exposure. In order to obtain the magnetic properties the B-H curves of these samples were measured. Cylindrical air-cored and printed circuit board (PCB) coil integrated sensors were used to measure the incremental permeability. Analytical and numerical methods (Finite Elements Methods) were employed to calculate the sensor response of these samples. The electromagnetic properties of the different steels were inferred by fitting the finite element models to the measured results. In addition, sensitivity and error analysis were carried out to evaluate the accuracy of the method.

  2. Personnel exposure control system with auto thermoluminescence dosimeter in Shimane Nuclear Power Station

    Energy Technology Data Exchange (ETDEWEB)

    Matsubayashi, Hideo; Ochi, Susumu (Chugoku Electric Power Co. Inc., Hiroshima (Japan))

    1982-03-01

    In the past, film badges and pocket dosimeters were put on the persons who entered a controlled area in a nuclear power station to measure the external radiation exposure. For these, read out error or mistake, delay in taking out the result, trouble for monitoring many persons, etc. were problems. To solve these problems, the auto thermoluminescence dosimeter (ATLD) system has been introduced in Shimane Nuclear Power Station in place of pocket dosimeters since the second half of fiscal 1978. The outline of the system and the composition and software of the TLD automatic readout system are described. For the control of access to controlled areas, workers are forced to pass the check point where watchmen check everyone's ID card, and subjected to the check-up with the TLD automatic readout device. The checking items in the case of entering the areas are: (1) confirmation of licensee, (2) confirmation of the term of validity for the medical examination on ionizing radiation, (3) checking for exposure dose compared to the controlled exposure level, (4) confirmation of time limit to stay in controlled areas, and (5) TLD element annealing condition. The checking items in the case of leaving the areas are: (1) checking for identifying the TLD element that the personnel has brought in, (2) exposure dose compared to the controlled exposure level, (3) time for which the personnel stayed in controlled areas.

  3. Asthma in the vicinity of power stations: II. Outdoor air quality and symptoms

    Energy Technology Data Exchange (ETDEWEB)

    Henry, R.L.; Bridgman, H.A.; Wlodarczyk, J.; Abramson, R.; Adler, J.A.; Hensley, M.J. (Disciplines of Paediatrics, University of Newcastle, New South Wales (Australia))

    1991-01-01

    To assess longitudinally the effect of living in the vicinity of coal-fired power stations on children with asthma, 99 schoolchildren with a history of wheezing in the previous 12 months were studied for 1 year, using daily diaries and measurements of air quality. The children had been identified in a cross-sectional survey of two coastal areas: Lake Munmorah (LM), within 5 km of two power stations, and Nelson Bay (NB), free from major industry. Daily air quality (sulphur dioxide (SO2) and nitrogen oxides (NOx)), respiratory symptoms, and treatment for asthma were recorded throughout the year. Measurements of SO2 and NOx at LM were well within recommended guidelines although they were several times higher than at NB: maximum daily levels in SO2 (micrograms/m3) were 26 at LM, 11 at NB (standard, 365); yearly average SO2 was 2 at LM, 0.3 at NB (standard, 60); yearly average NOx (micrograms/m3) was 2 at LM, 0.4 at NB (standard, 94). Marked weekly fluctuations occurred in the prevalence of cough, wheezing, and breathlessness, without any substantial differences between LM and NB. Overall, the prevalence of symptoms was low (10% for wheezing, 20% for any symptom). Whether the daily SO2 and NOx levels affected the occurrence of respiratory symptoms was investigated in children at LM using a logistic regression (Korn and Whittemore technique). For these children as a group, air quality measurements were not associated with the occurrence of symptoms.

  4. Artificial neural network application for space station power system fault diagnosis

    Science.gov (United States)

    Momoh, James A.; Oliver, Walter E.; Dias, Lakshman G.

    1995-01-01

    This study presents a methodology for fault diagnosis using a Two-Stage Artificial Neural Network Clustering Algorithm. Previously, SPICE models of a 5-bus DC power distribution system with assumed constant output power during contingencies from the DDCU were used to evaluate the ANN's fault diagnosis capabilities. This on-going study uses EMTP models of the components (distribution lines, SPDU, TPDU, loads) and power sources (DDCU) of Space Station Alpha's electrical Power Distribution System as a basis for the ANN fault diagnostic tool. The results from the two studies are contrasted. In the event of a major fault, ground controllers need the ability to identify the type of fault, isolate the fault to the orbital replaceable unit level and provide the necessary information for the power management expert system to optimally determine a degraded-mode load schedule. To accomplish these goals, the electrical power distribution system's architecture can be subdivided into three major classes: DC-DC converter to loads, DC Switching Unit (DCSU) to Main bus Switching Unit (MBSU), and Power Sources to DCSU. Each class which has its own electrical characteristics and operations, requires a unique fault analysis philosophy. This study identifies these philosophies as Riddles 1, 2 and 3 respectively. The results of the on-going study addresses Riddle-1. It is concluded in this study that the combination of the EMTP models of the DDCU, distribution cables and electrical loads yields a more accurate model of the behavior and in addition yielded more accurate fault diagnosis using ANN versus the results obtained with the SPICE models.

  5. Development of a power electronics unit for the Space Station plasma contactor

    Science.gov (United States)

    Hamley, John A.; Hill, Gerald M.; Patterson, Michael J.; Saggio, Joseph, Jr.; Terdan, Fred; Mansell, Justin D.

    1994-02-01

    A hollow cathode plasma contactor has been baselined as a charge control device for the Space Station (SS) to prevent deleterious interactions of coated structural components with the ambient plasma. NASA LeRC Work Package 4 initiated the development of a plasma contactor system comprised of a Power Electronics Unit (PEU), an Expellant Management Unit (EMU), a command and data interface, and a Plasma Contactor Unit (PCU). A breadboard PEU was designed and fabricated. The breadboard PEU contains a cathode heater and discharge power supply, which were required to operate the PCU, a control and auxiliary power converter, an EMU interface, a command and telemetry interface, and a controller. The cathode heater and discharge supplies utilized a push-pull topology with a switching frequency of 20 kHz and pulse-width-modulated (PWM) control. A pulse ignition circuit derived from that used in arcjet power processors was incorporated in the discharge supply for discharge ignition. An 8088 based microcontroller was utilized in the breadboard model to provide a flexible platform for controller development with a simple command/data interface incorporating a direct connection to SS Mulitplexer/Demultiplexer (MDM) analog and digital I/O cards. Incorporating this in the flight model would eliminate the hardware and software overhead associated with a 1553 serial interface. The PEU autonomously operated the plasma contactor based on command inputs and was successfully integrated with a prototype plasma contactor unit demonstrating reliable ignition of the discharge and steady-state operation.

  6. Maximizing power saving with state transition overhead for multiple mobile subscriber stations in WiMAX

    Institute of Scientific and Technical Information of China (English)

    Bo LI; Sung-kwon PARK

    2016-01-01

    In the IEEE 802.16e/m standard, three power saving classes (PSCs) are defined to save the energy of a mobile sub-scriber station (MSS). However, how to set the parameters of PSCs to maximize the power saving and guarantee the quality of service is not specified in the standard. Thus, many algorithms were proposed to set the PSCs in IEEE 802.16 networks. However, most of the proposed algorithms consider only the power saving for a single MSS. In the algorithms designed for multiple MSSs, the sleep state, which is set for activation of state transition overhead power, is not considered. The PSC setting for real-time connections in multiple MSSs with consideration of the state transition overhead is studied. The problem is non-deterministic polynomial time hard (NP-hard), and a suboptimal algorithm for the problem is proposed. Simulation results demonstrate that the energy saving of the proposed algorithm is higher than that of state-of-the-art algorithms and approaches the optimum limit.

  7. Development of a Power Electronics Unit for the Space Station Plasma Contactor

    Science.gov (United States)

    Hamley, John A.; Hill, Gerald M.; Patterson, Michael J.; Saggio, Joseph, Jr.; Terdan, Fred; Mansell, Justin D.

    1994-01-01

    A hollow cathode plasma contactor has been baselined as a charge control device for the Space Station (SS) to prevent deleterious interactions of coated structural components with the ambient plasma. NASA LeRC Work Package 4 initiated the development of a plasma contactor system comprised of a Power Electronics Unit (PEU), an Expellant Management Unit (EMU), a command and data interface, and a Plasma Contactor Unit (PCU). A breadboard PEU was designed and fabricated. The breadboard PEU contains a cathode heater and discharge power supply, which were required to operate the PCU, a control and auxiliary power converter, an EMU interface, a command and telemetry interface, and a controller. The cathode heater and discharge supplies utilized a push-pull topology with a switching frequency of 20 kHz and pulse-width-modulated (PWM) control. A pulse ignition circuit derived from that used in arcjet power processors was incorporated in the discharge supply for discharge ignition. An 8088 based microcontroller was utilized in the breadboard model to provide a flexible platform for controller development with a simple command/data interface incorporating a direct connection to SS Mulitplexer/Demultiplexer (MDM) analog and digital I/O cards. Incorporating this in the flight model would eliminate the hardware and software overhead associated with a 1553 serial interface. The PEU autonomously operated the plasma contactor based on command inputs and was successfully integrated with a prototype plasma contactor unit demonstrating reliable ignition of the discharge and steady-state operation.

  8. The micro power station of Verbois; Ouvrage Micro-centrale de Verbois

    Energy Technology Data Exchange (ETDEWEB)

    Quercia, P.; Martinez, J.-L. [Services industriels de Geneve, Service de l' electricite, Geneva (Switzerland)

    2005-07-01

    The policy of the public utilities of the City of Geneva includes the promotion of renewable energy and the conservation of the environment. The erection of the most important hydroelectric power plant in the canton of Geneva at Verbois, on the Rhone River dates back to the years 1938 to 1944. Several retrofits have been made since then, the last dating from 1996 to 1998. In 2000, due to ecological considerations, a fish ladder was added, resulting in a loss of generated power equivalent to a water flow of 2 m{sup 3}/s at a height of 18.35 meters. In order to compensate for this energy loss, a micro hydropower station with a maximum output power of 316 kW was added. It is fitted with a Francis turbine with horizontal axis and fixed opening; the rotation speed is 605 rpm. A reduced power output could be traced back to the deposition of solids on the grids upstream of the water supply duct. The necessary modifications are discussed.

  9. Electric Power Supply of Meat Processing Enterprise through Utilization Heat of Compressor Station Secondary Energy Sources in Main Gasline

    Directory of Open Access Journals (Sweden)

    A. Nesenchuk

    2013-01-01

    Full Text Available The paper considers a structure of power consumption by a meat processing enterprise with indication of specific power consumption norms in accordance with product nomenclature. Schemes for supply of the enterprise with heat and cold through utilization of compressor station secondary energy sources in main gasline have been presented in the paper.

  10. Models for the transient stability of conventional power generating stations connected to low inertia systems

    Science.gov (United States)

    Zarifakis, Marios; Coffey, William T.; Kalmykov, Yuri P.; Titov, Sergei V.

    2017-06-01

    An ever-increasing requirement to integrate greater amounts of electrical energy from renewable sources especially from wind turbines and solar photo-voltaic installations exists and recent experience in the island of Ireland demonstrates that this requirement influences the behaviour of conventional generating stations. One observation is the change in the electrical power output of synchronous generators following a transient disturbance especially their oscillatory behaviour accompanied by similar oscillatory behaviour of the grid frequency, both becoming more pronounced with reducing grid inertia. This behaviour cannot be reproduced with existing mathematical models indicating that an understanding of the behaviour of synchronous generators, subjected to various disturbances especially in a system with low inertia requires a new modelling technique. Thus two models of a generating station based on a double pendulum described by a system of coupled nonlinear differential equations and suitable for analysis of its stability corresponding to infinite or finite grid inertia are presented. Formal analytic solutions of the equations of motion are given and compared with numerical solutions. In particular the new finite grid model will allow one to identify limitations to the operational range of the synchronous generators used in conventional power generation and also to identify limits, such as the allowable Rate of Change of Frequency which is currently set to ± 0.5 Hz/s and is a major factor in describing the volatility of a grid as well as identifying requirements to the total inertia necessary, which is currently provided by conventional power generators only, thus allowing one to maximise the usage of grid connected non-synchronous generators, e.g., wind turbines and solar photo-voltaic installations.

  11. Modern concepts of thermodynamic optimization in Mexican thermoelectric power stations; Conceptos modernos de optimacion termodinamica en centrales termoelectricas mexicanas

    Energy Technology Data Exchange (ETDEWEB)

    Cervantes de Gortari, J.; Vidal Santo, A.; Mendez Lavielle, F.; Bautista Godinez, O. [Facultad de Ingenieria, UNAM, Mexico, D.F. (Mexico)

    2002-03-01

    In this paper, a summary review of the current thermodynamic concepts to the maximum power generation and minimum entropy production are presented. The results of the analysis are considered in Mexican power stations using conventional cycles and are compared with other power stations around the world. [Spanish] En este trabajo se revisa el analisis de maxima generacion de potencia que implica la minimizacion de la produccion de entropia en centrales generadoras de potencia, de acuerdo con los lineamientos mas recientes publicados en la literatura. Los conceptos y resultados del analisis se aplican a varias centrales mexicanas y se comparan con otras centrales en el mundo.

  12. LIGHTWEIGHT CONCRETES WITH FLY–ASH OF PRYDNIPROVSK THERMAL POWER STATION

    Directory of Open Access Journals (Sweden)

    M. I. Netesa

    2013-08-01

    Full Text Available Purpose. Determination of conformities to law of influence of expense of components of easy concretes, which turn out on the basis of local afterproducts of industry, on their basic properties under conditions of enhanceable efficiency of the use of cement. Methodology. Experimental studies on optimization of structures and properties of concrete were carried out with use of mathematical planning experiments methods. All experiments were carried out on orthogonal design with three variables. Cement, water and additives PLKP-2 consumption were taken as varied factors. Findings. Vast experimental studies on determination of rational compositions of concrete mixtures were conducted with the use as fillers of granulated slag from iron and steel plant named after Petrovskiy and Dnepr sand, as binding agent Krivoy Rog portland-cement II/B-Ш-400, as filler fly-ash of Pridneprovsk Thermal Power Station. Efficiency coefficient of cement use was adopted as basic criterion of concrete composition rationality, it is determined on the relation of the attained durability per unit weight of used cement. For greater efficiency coefficient of cement use regularity of rational grain composition of components previously obtained was adopted, it is provided at a ratio of a large fraction consumption to medium and small 52:23:25, and their sizes are approximately 100:10:1. Experimental studies with use of mathematical planning experiments method were carried out. By results of their processing isofields were constructed according to the strength and effectiveness of the use of cement ratio of the studied factors. Originality. By strength comparative tests of hardened concrete with various local secondary resources, modified with complex plasticizer PLKP-2 additive, it was found that lightweight concrete with the density of 1700…1800 kg/m3 and concrete compressive strength from 5 to 20 MPa on the basis of granulated slag from the iron and steel plant named after

  13. Evaluation of Wind Power Resources in Yanhu Wind Power Station%新疆盐湖风电场风能资源评估分析

    Institute of Scientific and Technical Information of China (English)

    于丽洁

    2014-01-01

    Yanhu wind power station is a new planned project for wind power development .An evaluation of the wind power resources in Yanhu wind power station is carried out .Based on measured data from anemometer tower #2794-1a, the annual wind power parameter , wind direction frequency , distribution of wind power density direction , wind speed frequency , wind power frequency , turbulence intensity and wind shear index are analyzed .Results show that the wind power density of Yanhu wind power station is about grade four .The main wind direction is consistent with the wind power density direction .The wind power frequency is also mainly distributed in intermediate wind speed interval .It shows that the wind power resources in Yanhu wind power station is abundant and profitable for development .%盐湖风电场是规划建设的新风电场,为了更好地利用其风能资源,对盐湖风电场的风能资源进行了评估分析。依据测风塔2794号1 a的测风数据,主要分析了年风能参数、风向频率和风能密度方向分布、风速频率及风能频率、湍流强度以及风切变指数。结果表明:盐湖风电场风功率密度达到4级;主风向与风能密度分布主方向一致;风能频率主要分布在中等风速段;盐湖风电场的风能资源丰富,具有很好的开发价值。

  14. A fault diagnosis system for PV power station based on global partitioned gradually approximation method

    Science.gov (United States)

    Wang, S.; Zhang, X. N.; Gao, D. D.; Liu, H. X.; Ye, J.; Li, L. R.

    2016-08-01

    As the solar photovoltaic (PV) power is applied extensively, more attentions are paid to the maintenance and fault diagnosis of PV power plants. Based on analysis of the structure of PV power station, the global partitioned gradually approximation method is proposed as a fault diagnosis algorithm to determine and locate the fault of PV panels. The PV array is divided into 16x16 blocks and numbered. On the basis of modularly processing of the PV array, the current values of each block are analyzed. The mean current value of each block is used for calculating the fault weigh factor. The fault threshold is defined to determine the fault, and the shade is considered to reduce the probability of misjudgments. A fault diagnosis system is designed and implemented with LabVIEW. And it has some functions including the data realtime display, online check, statistics, real-time prediction and fault diagnosis. Through the data from PV plants, the algorithm is verified. The results show that the fault diagnosis results are accurate, and the system works well. The validity and the possibility of the system are verified by the results as well. The developed system will be benefit for the maintenance and management of large scale PV array.

  15. The Opportunity Analyses of Using Thermosyphons in Cooling Systems of Power Transformers on Thermal Stations

    Directory of Open Access Journals (Sweden)

    Nurpeiis Аtlant

    2016-01-01

    Full Text Available The opportunity analyses of using the thermosyphons as the main elements in the systems of thermal regime supplying has been conducted under the conditions of their usage in power transformers on thermal stations. Mathematical modeling of jointly proceeding processes of conduction, forced convection and phase transitions (evaporation and condensation of coolant in the thermosyphon of rectangular cross section has been carried out. The problem of conjugated conductive-convective heat transfer was formulated in dimensionless variables “vorticity/stream function/temperature” and solved by finite difference method. The effect of the heat flux density supplied to the bottom cover of the thermosyphon from a transformer tank on the temperature drop in the steam channel was shown based on the analysis of numerical simulation results (temperature fields and velocities of steam. The parameters of energy-saturated equipment of thermal stations were found to be controlled by an intensification of heat removal from the top cover surface of the thermosyphon.

  16. Hybrid wind-PV grid connected power station case study: Al Tafila, Jordan

    Energy Technology Data Exchange (ETDEWEB)

    El-Tous, Yousif [Department of Electrical Engineering/Faculty of Engineering Technology/ Al-Balqa' Applied University, Amman, P.O.Box (15008), Marka Ashamalia (Jordan); Al-Battat, Saleh [Department of substation maintenance and protection, National Electric Power Company (NEPCO), Amman (Jordan); Abdel Hafith, Sandro [Department of technical support and project supervision/Integrated power systems co., Amman (Jordan)

    2012-07-01

    In this paper, we are providing an attempt to highlight the importance of renewable energy, more specifically, the one produced from a wind-solar hybrid system. This purpose will be achieved through providing a detailed case study for such system that would be applied in Al-Tafila, Jordan. First and foremost site assessment has been conducted based on an intensive literature review for the data available regarding the availability of wind and solar energy in Jordan and resulted in the selection of Al-Tafila 2 district as the best option among all. Then, the components of the power station and its size have been selected based on specific criteria that make the station as much efficient and competitive as possible. To obtain the output of the different components with respect to the demand for a period of 25 years, a system model was built using HOMER. Finally, the total capital cost of the system was calculated and resulted to be (63400168) $ and with a cost of energy of (0.053) $/kWh which is a very competitive and feasible cost compared to similar international projects and to the conventional energy price.

  17. The International Remote Monitoring Project -- First results of the Argentina nuclear power station field trial

    Energy Technology Data Exchange (ETDEWEB)

    Bonino, A.; Pizarro, L.; Perez, A. [Ente Nacional Regulador Nuclear, Buenos Aires (Argentina); Schoeneman, J.L.; Dupree, S.A.; Martinez, R.L. [Sandia National Labs., Albuquerque, NM (United States); Maxey, C. [Oak Ridge National Lab., TN (United States)

    1995-12-31

    As part of the International Remote Monitoring Project field trials, during the month of March, 1995 a Remote Monitoring System (RMS) was installed at the Embalse Nuclear Power Station in Embalse, Argentina. This system monitors the status of four typical Candu spent fuel dry storage silos. The monitoring equipment for each silo consists of analog temperature and gamma radiation sensors and digital motion and electronic fiber-optic seals connected to a wireless Authenticate Item Monitoring System (AIMS). All sensor data are authenticated and transmitted via RF link to Receiver Processor Units (RPU) coupled to Remote Monitoring System equipment located in a nearby IAEA/ENREN inspector office. One of these RPUs is connected to Remote Monitoring equipment capable of information transmission (via commercial telephone links) to Data Review Stations (DRS) at ENREN laboratories in Buenos Aires, Argentina, and at Sandia National Laboratories, Albuquerque, New Mexico. The other RPU is used for on-site data storage and analysis. It is anticipated that this information will soon be transmitted to a DRS at the ABACC facility in Rio de Janeiro, Brazil. During these trials site data will be collected and analyzed periodically from Buenos Aires, Albuquerque, and Rio de Janeiro. Installation detail and data analysis will be presented in this paper.

  18. Trace elements emission from coal-fired power stations in Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Altamirano-Bedolla, J.A.; Wong-Moreno, A.; Romo-Millares, C.A.

    1999-07-01

    This paper presents partial results of work currently in progress to determine trace elements emissions associated with the coal combustion from coal-fired power stations in Mexico. It shows the progress of the first year of a five-year project, supported by the Mexican Ministry of Energy with the aim of developing methods to obtain representative samples, perform reliable analysis and produce accurate quantification and classification of these emissions. A description of the sampling procedures and analysis performed to the coal, bottom ash, fly ash and total suspended particles in flue gas are given. Some results are provided and discussed as an example of the large amount of information that will be analyzed in the future to produce conclusions regarding trace elements from coal fired stations in Mexico. Elements such as Mercury, Arsenic, Lead, Nickel, Chromium, Cadmium, Copper, Zinc, Manganese, Cobalt, Selenium, Atimony, Vanadium, Barium, Strontium, Boron and Molybdenum were analyzed by Atomic Absorption Spectroscopy (AAS) using Flame AAS, Hydride Generation AAS and Cold Vapor AAS. Scanning Electron Microscopy and Electron Probe Microanalysis (SEM-EDX) was also used to identify some of the elements.

  19. Hybrid wind-PV grid connected power station case study: Al Tafila, Jordan

    Directory of Open Access Journals (Sweden)

    Yousif El-Tous, Saleh Al-Battat, Sandro Abdel Hafith

    2012-01-01

    Full Text Available In this paper, we are providing an attempt to highlight the importance of renewable energy, more specifically, the one produced from a wind-solar hybrid system. This purpose will be achieved through providing a detailed case study for such system that would be applied in Al-TafilaJordan. First and foremost site assessment has been conducted based on an intensive literature review for the data available regarding the availability of wind and solar energy in Jordan and resulted in the selection of Al-Tafila 2 district as the best option among all. Then, the components of the power station and its size have been selected based on specific criteria that make the station as much efficient and competitive as possible. To obtain the output of the different components with respect to the demand for a period of 25 years, a system model was built using HOMER. Finally, the total capital cost of the system was calculated and resulted to be (63400168 $ and with a cost of energy of (0.053 $/kWh which is a very competitive and feasible cost compared to similar international projects and to the conventional energy price.

  20. Ticks (Acari: Ixodidae on wild animals from the Porto-Primavera Hydroelectric power station area, Brazil

    Directory of Open Access Journals (Sweden)

    Marcelo B Labruna

    2002-12-01

    Full Text Available From June 2000 to June 2001, a total of 741 ticks were collected from 51 free-living wild animals captured at the Porto-Primavera Hydroelectric power station area, located alongside an approximately 180 km course of the Paraná river, between the states of São Paulo and Mato Grosso do Sul, comprising 9 species of 3 genera: Ambly-omma (7 species, Boophilus (1 and Anocentor (1. A total of 421 immature Amblyomma ticks were reared in laboratory until the adult stage, allowing identification of the species. A. cajennense was the most frequent tick species (mostly immature stages collected on 9 host species: Myrmecophaga tridactyla, Tamandua tetradactyla,Cerdocyon thous, Puma concolor,Tayassu tajacu, Mazama gouazoubira,Hydrochaeris hydrochaeris,Alouatta caraya, Cebus apella. Other tick species were less common, generally restricted to certain host taxa.

  1. Analysis and evaluation of "noise" of occupational hazards in pumped storage power station

    Science.gov (United States)

    Zhao, Xin; Yang, Hongjian; Zhang, Huafei; Chen, Tao

    2017-05-01

    Aiming at the influence of "noise" of occupational hazards on the physical health of workers, the noise intensity of a working area of a hydropower station in China was evaluated comprehensively. Under the condition of power generation, noise detection is conducted on the main patrol area of the operator, and the noise samples in different regions are analyzed and processed by the single factor analysis of variance. The results show that the noise intensity of different working areas is significantly different, in which the overall noise level of the turbine layer is the highest and beyond the national standard, the protection measures need to be strengthened and the noise intensity of the rest area is normal

  2. Construction of a cooling water inlet system with settling basin of Derna power plant station (Libya)

    Energy Technology Data Exchange (ETDEWEB)

    Glissmann, R.; Heimburg, A.M. von; Sinner, H.

    1985-03-01

    Construction of a cooling water intake system with settling basin. The extension of the power station at Derna, in Libya, necessitated the construction of a new cooling water intake system including screening facilities and a settling basin. Construction based on extensive prefabrication (precast concrete) was chosen. The precast reinforced units, ranging up to about 4000 t in weight, were towed on barges to the site of erection. At Derna these units were temporarily stored on the sea bed for several months, during which they were exposed to winter storms and rough sea. The major precast portion of the settling basin was constructed direct on the barge. On arrival at the site, the barge was sunk, allowing the precast unit, which was designed with sufficient buoyancy, to be floated off. The open unprotected coast required special arrangements for the protection of personnel, structures and equipment.

  3. Characterization of Fly Ash Generated from Matla Power Station in Mpumalanga, South Africa

    Directory of Open Access Journals (Sweden)

    Olushola S. Ayanda

    2012-01-01

    Full Text Available In this study, fly ash was obtained from Matla power station and the physicochemical properties investigated. The fly ash was characterized by x-ray fluorescence, x-ray diffraction, scanning electron microscopy, and inductively coupled plasma mass spectrometry. Surface area, particle size, ash and carbon contents, pH, and point of zero charge were also measured. The results showed that the fly ash is alkaline and consists mainly of mullite (Al6Si2O13 and quartz (SiO2. Highly toxic metals As, Sb, Cd, Cr, and Pb as well as metals that are essential to health in trace amounts were also present. The storage and disposal of coal fly ash can thus lead to the release of leached metals into soils, surface and ground waters, find way into the ecological systems and then cause harmful effect to man and its environments.

  4. A contribution to the problems of utilizing coal combustion wastes from the EVO Vojany power station

    Directory of Open Access Journals (Sweden)

    Marta Benková

    2006-04-01

    Full Text Available In the contribution the procedures mineral processing technologies are presented. By their application, individual valuable components are of gained from the solid waste of black coalfired in a power station. The flotation product of unburned coal rests is characterized by 85 – 86 % loss ignition. The magnetic product (usually is it a new mineral formation of magnetite includes 47 – 49 % Fe. The fly ash which is free of the unburned coal rests and magnetite iron includes only 1.02 – 1.34 % loss ignition and 5.38 – 4.71 % Fe. The products from the can be usable in several industrial areas (building industry, metallurgy, etc.

  5. Combustion Quality Estimation in Power Station Boilers using Median Threshold Clustering Algorithms

    Directory of Open Access Journals (Sweden)

    K.Sujatha

    2010-07-01

    Full Text Available The estimation of combustion quality in power station boilers is of great importance in the present scenario as it plays an important role in controlling the air pollution. The harmful gases like NOx and CO from the chimney causes air pollution. The amount of NOx and CO concentration in flue gas can be maintained within admissible limits by analyzing the flame colour. The colour of the flame is affected by combustion quality. When complete combustion takes place the amount these gases at the exit are within tolerance. Hence if the quality of combustion was estimated from the flame using image processing technique, it is possible to minimize the air pollution. This new strategy developed uses median threshold for feature reduction and various clustering algorithms to estimate the quality of combustion.

  6. Mast material test program (MAMATEP). [for Solar Array Assembly of Space Station Photovoltaic Power Module

    Science.gov (United States)

    Ciancone, Michael L.; Rutledge, Sharon K.

    1988-01-01

    The MAMATEP program, which is aimed at verifying the need for and evaluating the performance of various protection techniques for the solar array assembly mast of the Space Station photovoltaic power module, is discussed. Coated and uncoated mast material samples have been environmentally tested and evaluated, before and after testing, in terms of mass and bending modulus. The protective coatings include CV-1144 silicone, a Ni/Al/InSn eutectic, and an open-weave Al braid. Long-term plasma asher results from unprotected samples indicate that, even though fiberglass-epoxy samples degrade, a protection technique may not be necessary to ensure structural integrity. A protection technique, however, may be desirable to limit or contain the amount of debris generated by the degradation of the fiberglass-epoxy.

  7. Ticks (Acari: Ixodidae) on wild animals from the Porto-Primavera Hydroelectric power station area, Brazil.

    Science.gov (United States)

    Labruna, Marcelo B; de Paula, Cátia D; Lima, Thiago F; Sana, Dênis A

    2002-12-01

    From June 2000 to June 2001, a total of 741 ticks were collected from 51 free-living wild animals captured at the Porto-Primavera Hydroelectric power station area, located alongside an approximately 180 km course of the Paran river, between the states of S o Paulo and Mato Grosso do Sul, comprising 9 species of 3 genera: Ambly-omma (7 species), Boophilus (1) and Anocentor (1). A total of 421 immature Amblyomma ticks were reared in laboratory until the adult stage, allowing identification of the species. A. cajennense was the most frequent tick species (mostly immature stages) collected on 9 host species: Myrmecophaga tridactyla, Tamandua tetradactyla,Cerdocyon thous, Puma concolor,Tayassu tajacu, Mazama gouazoubira,Hydrochaeris hydrochaeris,Alouatta caraya, Cebus apella. Other tick species were less common, generally restricted to certain host taxa.

  8. Evaluation of activated nuclides for Fugen Nuclear Power Station's decommissioning

    Energy Technology Data Exchange (ETDEWEB)

    Shiratori, Yoshitake; Kawagoe, Shinji; Matsui, Yuji; Higashiura, Norikazu [Japan Nuclear Cycle Development Inst., Tsuruga Head Office, Tsuruga, Fukui (Japan); Iwasaki, Seiji [Nuclear Energy System Inc., Tokyo (Japan)

    2002-09-01

    The density and amount of radioactive nuclides in equipment or concrete including the reactor core need to be evaluated for the decommissioning of the Fugen Nuclear Power Station. To prepare for decommissioning, measurement and evaluation of the neutron flux density have been executed mainly during the reactor operation, because neutron flux density is measured under that condition. Activation evaluation is mainly executed by the calculation method, and the results are checked by the sampling measurements. All of the equipments is divided into three parts, inner core part, shielding part, outer shielding part. The neutron flux distribution of two former parts can be evaluated by calculation, but the last part cannot; it is evaluated by measuring the activation foil for many points. These evaluation methods are checked by a small number of sampling measurements. (author)

  9. International Remote Monitoring Project Embalse Nuclear Power Station, Argentina Embalse Remote Monitoring System

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, Sigfried L.; Glidewell, Donnie D.; Bonino, Anibal; Bosler, Gene; Mercer, David; Maxey, Curt; Vones, Jaromir; Martelle, Guy; Busse, James; Kadner, Steve; White, Mike; Rovere, Luis

    1999-07-21

    The Autoridad Regulatoria Nuclear of Argentina (ARN), the International Atomic Energy Agency (IAEA), ABACC, the US Department of Energy, and the US Support Program POTAS, cooperated in the development of a Remote Monitoring System for nuclear nonproliferation efforts. This system was installed at the Embalse Nuclear Power Station last year to evaluate the feasibility of using radiation sensors in monitoring the transfer of spent fuel from the spent fuel pond to dry storage. The key element in this process is to maintain continuity of knowledge throughout the entire transfer process. This project evaluated the fundamental design and implementation of the Remote Monitoring System in its application to regional and international safeguard efficiency. New technology has been developed to enhance the design of the system to include storage capability on board sensor platforms. This evaluation has led to design enhancements that will assure that no data loss will occur during loss of RF transmission of the sensors.

  10. Indian Point Nuclear Power Station: verification analysis of County Radiological Emergency-Response Plans

    Energy Technology Data Exchange (ETDEWEB)

    Nagle, J.; Whitfield, R.

    1983-05-01

    This report was developed as a management tool for use by the Federal Emergency Management Agency (FEMA) Region II staff. The analysis summarized in this report was undertaken to verify the extent to which procedures, training programs, and resources set forth in the County Radiological Emergency Response Plans (CRERPs) for Orange, Putnam, and Westchester counties in New York had been realized prior to the March 9, 1983, exercise of the Indian Point Nuclear Power Station near Buchanan, New York. To this end, a telephone survey of county emergency response organizations was conducted between January 19 and February 22, 1983. This report presents the results of responses obtained from this survey of county emergency response organizations.

  11. Photocatalytic treatment of IGCC power station effluents in a UV-pilot plant.

    Science.gov (United States)

    Durán, A; Monteagudo, J M; San Martín, I; Sánchez-Romero, R

    2009-08-15

    The aim of this work is to improve the quality of water effluents coming from an Integrated Gasification Combined Cycle (IGCC) power station to meet with future environmental legislation. This study has been made using an homogeneous photocatalytic oxidation process (UV/Fe(II)/H(2)O(2)) in a pilot plant. The efficiency of the process was determined from the analysis of the following parameters: cyanides, formates and TOC content. In the first stage, a factorial experimental design allowed to determine the influence of operation variables (initial concentration of H(2)O(2) and Fe(II), pH and temperature) on the degradation kinetics. pH was always kept in a value >9.5 during cyanides destruction to avoid gaseous HCN formation and lowered later to enhance formates degradation. Experimental kinetic constants were fitted using neural networks (NNs). Under the optimum conditions ([H(2)O(2)]=1700 ppm, [Fe(II)]=2 ppm, pH 2 after cyanides destruction, and T=30 degrees C), it is possible to degrade 100% of cyanides in 15 min and 76% of formates in 120 min. The use of an homogeneous process with UV light can offer an economical and practical alternative to heterogeneous photocatalysis for the destruction of environmental pollutants present in thermoelectric power stations effluents, since it can treat very high flowrates using a lower H(2)O(2) concentration. Furthermore, it does not require additional operations to recover the solid catalyst and regenerate it due to deactivation as occurs in heterogeneous catalysis.

  12. Environmental radiological studies downstream from Rancho Seco Nuclear Power Generating Station

    Energy Technology Data Exchange (ETDEWEB)

    Noshkin, V.E.; Wong, K.M.; Eagle, R.J.; Dawson, J.W.; Brunk, J.L.; Jokela, T.A.

    1985-03-22

    This report summarizes the information compiled in 1984 while assessing the environmental impact of radionuclides in aquatic releases from the Rancho Seco Nuclear Power Generating Station. Gamma-emitting radionuclides discharged since 1981 are found in many of the dietary components derived from the creeks receiving the effluent wastewater. Some soils and crops are found to contain radionuclides that originate from the contaminated water that was transferred to land during the irrigation season. /sup 134/Cs and /sup 137/Cs are the primary gamma-emitting radionuclides detected in the edible flesh of fish from the creeks. Concentrations in the flesh of fish decreased exponentially with distance from the plant. No significant differences in the /sup 137/Cs activity were found between male and female fish of equal size, but concentrations may vary in fish of different size, with the season and diet. 21% of the total /sup 137/Cs and /sup 134/Cs discharged between 1981 and 1984 is associated with the creek sediments to a distance of 27 km from the plant. Fractions of the missing inventory have been transferred to land during the irrigation season or to downstream regions more distant than 27 km from the plant. The radiocesium content of the sediments in 1984 decreased significantly in a downstream direction, much in the same manner as concentrations decreased in fish. Radioactivity originating from the plant was not above detection limits in any terrestrial food item sampled beyond 6.5 km from the plant. Based on the usage factors provided by individuals interviewed in a 1984 survey, the fish and aquatic-organism ingestion pathway contributed the largest radiological dose to humans utilizing products contaminated with the radionuclides in the liquid wastes discharged from the Rancho Seco Nuclear Power Generating Station in 1984.

  13. Realisation and instrumentation of high current power station for superconducting cables testing; Realisation et instrumentation d'une station fort courant pour le test de cables supraconducteurs

    Energy Technology Data Exchange (ETDEWEB)

    Regnaud, S

    2000-05-01

    This report deals with the designing of a high current station able to test electric properties of superconductors. This test station will be used for testing the superconducting wires of large hadron collider detectors in CERN. The high current test station will have to generate high intensity continuous current in a magnetic field of 0 to 5 tesla and in temperature conditions of 4.2 K. The length of wire samples submitted to the uniform magnetic field is 300 mm and the installation is fitted with equipment able to measure the magnetic field perpendicular to either faces of the wire. The peculiarity of this station is to use a superconducting transformer in order to generate the high current. The first part of this work recalls important notions concerning superconductivity. The second part presents the high current station by describing the superconducting transformer and the sample-holder. We have studied the designing of a transformer able to yield a secondary current whose intensity reaches 100 kA, such intensity generates powerful electromagnetic forces (566 kN/m) in case of defect, so the sample-holder has to be carefully design to bear them. The third part presents the cryogenic component of the station, the instrumentation of the sample-holder and the method used to measure secondary currents. In the last part we present the performance of a prototype transformer, this prototype is able to deliver a 22 kA secondary current for a 160 A primary current, the uncertainty on the measured value of the secondary current is about 3%.

  14. Electron Microscope Center Opens at Berkeley.

    Science.gov (United States)

    Robinson, Arthur L.

    1981-01-01

    A 1.5-MeV High Voltage Electron Microscope has been installed at the Lawrence Berkeley Laboratory which will help materials scientists and biologists study samples in more true-to-life situations. A 1-MeV Atomic Resolution Microscope will be installed at the same location in two years which will allow scientists to distinguish atoms. (DS)

  15. Secondary electrical design of station service power supply system for Lunzua Power Station in Zambia%赞比亚Lunzua水电站厂用电系统二次设计

    Institute of Scientific and Technical Information of China (English)

    袁艳艳; 黄卫平

    2015-01-01

    介绍了赞比亚Lunzua水电站厂用电系统二次设计思路,针对国外工程的特殊要求,将建筑电气常用的自动转换开关的自动化功能应用于水电站厂用电的自动化设计中,并研究了一套自动转换开关和柴油机自动投退相配合的厂用电自动化方案,实现了母线电源的自动切换和恢复,柴油发电机的自动启动、投入和停止。工程投运后,运行正常。%An introduction was made on the secondary electrical design ideas of station service power supply system of Lunzua Power Station in Zambia. In view of the special requirements of overseas projects, automatic transfer switch frequently used in architectural electric system was adopted in the station service power supply system of power station. Cooperation between automatic transfer switch and diesel generator under automatic on/off control permits automatic transfer and recovery of bus power, automatic start, operating or shutdown of diesel generator.The project has been operating normally since it was put into operation.

  16. Tampa Electric Company Polk Power Station Unit Number 1. Annual report, January--December, 1993

    Energy Technology Data Exchange (ETDEWEB)

    1994-08-01

    This report satisfies the requirements of Cooperative Agreement DE-FC21-91MC27363, novated as of March 5, 1992, to provide an annual update report on the year`s activities associated with Tampa Electric Company`s 250 MW IGCC demonstration project for the year 1993. Tampa Electric Company`s Polk Power Station Unit 1 (PPS-1) Integrated Gasification Combined Cycle (IGCC) demonstration project will use a Texaco pressurized, oxygen-blown, entrained-flow coal gasifier to convert approximately 2,000 tons per day of coal (dry basis) coupled with a combined cycle power block to produce a net 250 MW electrical power output. Approximately 50% of the raw, hot syngas is cooled to 900 F and passed through a moving bed of zinc-based sorbent which removes sulfur containing compounds from the syngas. The remaining portion of the raw, hot syngas is cooled to 400 F for conventional acid gas removal. Sulfur-bearing compounds from both cleanup systems are sent to a conventional sulfuric acid plant to produce a marketable, high-purity sulfuric acid by-product. The cleaned medium-BTU syngas from these processes is routed to the combined cycle power generation system where it is mixed with air and burned in the combustion section of the combustion turbine. Heat is extracted from the expanded exhaust gases in a heat recovery steam generator (HRSG) to produce steam at three pressure levels for use throughout the integrated process. A highly modular, microprocessor-based distributed control system (DCS) is being developed to provide continuous and sequential control for most of the equipment on PPS-1.

  17. The assessment of external photon dose rate in the vicinity of nuclear power stations. An intercomparison of different monitoring systems

    DEFF Research Database (Denmark)

    Thompson, I.M.G.; Bøtter-Jensen, L.; Lauterbach, U.

    1993-01-01

    to a nuclear power station. The responses of each of these detectors to the natural radiation and to the radiation from the power station are given. Estimations by three of the dose rate instruments of the air kerma from all the radiation components are intercompared with the results from three different types...... of thermoluminescence dosemeter. The results clearly demonstrate that accurate estimations of doses in the environment arising from a nuclear facility can only be obtained if the responses of the detectors used to the different radiation components at that location are accurately evaluated. By correcting the measured...

  18. Space Station Power Generation in Support of the Beta Gimbal Anomaly Resolution

    Science.gov (United States)

    Delleur, Ann M.; Propp, Timothy W.

    2003-01-01

    The International Space Station (ISS) is the largest and most complex spacecraft ever assembled and operated in orbit. The first U.S. photovoltaic (PV) module, containing two solar arrays, was launched, installed, and activated in early December 2000. After the first week of continuously rotating the U.S. solar arrays, engineering personnel in the ISS Mission Evaluation Room (MER) observed higher than expected electrical currents on the drive motor in one of the Beta Gimbal Assemblies (BGA), the mechanism used to maneuver a U.S. solar array. The magnitude of the motor currents continued to increase over time on both BGA's, creating concerns about the ability of the gimbals to continue pointing the solar arrays towards the sun, a function critical for continued assembly of the ISS. A number of engineering disciplines convened in May 2001 to address this on-orbit hardware anomaly. This paper reviews the ISS electrical power system (EPS) analyses performed to develop viable operational workarounds that would minimize BGA use while maintaining sufficient solar array power to continue assembly of the ISS. Additionally, EPS analyses performed in support of on-orbit BGA troubleshooting exercises is reviewed. EPS capability analyses were performed using SPACE, a computer code developed by NASA Glenn Research Center (GRC) for the ISS program office.

  19. Space Station Module Power Management and Distribution System (SSM/PMAD)

    Science.gov (United States)

    Miller, William; Britt, Daniel; Elges, Michael; Myers, Chris

    1994-05-01

    This report provides an overview of the Space Station Module Power Management and Distribution (SSM/PMAD) testbed system and describes recent enhancements to that system. Four tasks made up the original contract: (1) common module power management and distribution system automation plan definition; (2) definition of hardware and software elements of automation; (3) design, implementation and delivery of the hardware and software making up the SSM/PMAD system; and (4) definition and development of the host breadboard computer environment. Additions and/or enhancements to the SSM/PMAD test bed that have occurred since July 1990 are reported. These include: (1) rehosting the MAESTRO scheduler; (2) reorganization of the automation software internals; (3) a more robust communications package; (4) the activity editor to the MAESTRO scheduler; (5) rehosting the LPLMS to execute under KNOMAD; implementation of intermediate levels of autonomy; (6) completion of the KNOMAD knowledge management facility; (7) significant improvement of the user interface; (8) soft and incipient fault handling design; (9) intermediate levels of autonomy, and (10) switch maintenance.

  20. CFD Ventilation Study for the Human Powered Centrifuge at the International Space Station

    Science.gov (United States)

    Son, Chang H.

    2011-01-01

    The Human Powered Centrifuge (HPC) is a hyper gravity facility that will be installed on board the International Space Station (ISS) to enable crew exercises under the artificial gravity conditions. The HPC equipment includes a bicycle for long-term exercises of a crewmember that provides power for rotation of HPC at a speed of 30 rpm. The crewmember exercising vigorously on the centrifuge generates the amount of carbon dioxide of several times higher than a crewmember in ordinary conditions. The goal of the study is to analyze the airflow and carbon dioxide distribution within Pressurized Multipurpose Module (PMM) cabin. The 3D computational model included PMM cabin. The full unsteady formulation was used for airflow and CO2 transport modeling with the so-called sliding mesh concept is considered in the rotating reference frame while the rest of the cabin volume is considered in the stationary reference frame. The localized effects of carbon dioxide dispersion are examined. Strong influence of the rotating HPC equipment on the CO2 distribution is detected and discussed.

  1. Evaluation of Lyse wind power station 1992-1995. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Thor, S.E. [comp.] [National Defence Research Establishment (Sweden)

    1996-11-01

    The main aim of the project was to test and evaluate a new wind power technique, partly through detailed measurements of the NWP 400 and partly through comparisons with the Danish standard unit. At the same time, it was a demand that the two units of the Power Station could be run as a production plant once the evaluation was complete. The overall conclusion from operation, and from the various measurements and studies carried out, is that the new technique functions as intended and that the calculations and estimates made in connection with design work were largely correct. The evaluation confirms that the unit can meet expected production levels, that it can cope with different operation situations and that it can be expected to meet the demands set for loads and safety with regard to fatigue. The evaluation has also shown that the calculation tools used to design the unit and calculate the production capacity have given correct results and good estimates. Certain sub-systems did not, however, function as intended and modifications were required. Additional modifications may be required in a series production of NWP 400. In its present form the unit has difficulties at high wind speeds due to large teeter movements. According to calculations, it should be possible to further reduce these teeter movements and thus increase the availability. The comparison between the units shows that both of the units have largely achieved the expected production capacity. 83 figs, 17 tabs

  2. Medium Powered Sound Broadcasting Station ZS-82 (“The Decorator” as a Weapon of Propagandists

    Directory of Open Access Journals (Sweden)

    Aleksey A. Romanchuk

    2016-06-01

    Full Text Available This article considers tactical and technical characteristics of a Russian army’s propaganda weapon – the medium powered sound broadcasting station ZS-82 (“The Decorator” on a base of open sources. The sources used for the compilation of this article were various open source data, such as official news websites, forums, educational and scientific literature. Despite some thematic diversity, this topic is presented quite limitedly in the open access. We used general scientific methods, analysis and synthesis methods, concretization and generalization in solving research problems. The use of these techniques allowed us to create a complete picture of combat use of this technology in local conflicts at the end of XX – beginning of XXI centuries. In conclusion, it is indicated that the Russian army arsenal possesses an effective means of advocacy – the medium powered ZS-82 “The Decorator”. Despite its limited combat use, practice showed that this equipment can be used for conducting negotiations (agitation, as well for performing disinformation activities.

  3. Computational Fluid Dynamics Ventilation Study for the Human Powered Centrifuge at the International Space Station

    Science.gov (United States)

    Son, Chang H.

    2012-01-01

    The Human Powered Centrifuge (HPC) is a facility that is planned to be installed on board the International Space Station (ISS) to enable crew exercises under the artificial gravity conditions. The HPC equipment includes a "bicycle" for long-term exercises of a crewmember that provides power for rotation of HPC at a speed of 30 rpm. The crewmember exercising vigorously on the centrifuge generates the amount of carbon dioxide of about two times higher than a crewmember in ordinary conditions. The goal of the study is to analyze the airflow and carbon dioxide distribution within Pressurized Multipurpose Module (PMM) cabin when HPC is operating. A full unsteady formulation is used for airflow and CO2 transport CFD-based modeling with the so-called sliding mesh concept when the HPC equipment with the adjacent Bay 4 cabin volume is considered in the rotating reference frame while the rest of the cabin volume is considered in the stationary reference frame. The rotating part of the computational domain includes also a human body model. Localized effects of carbon dioxide dispersion are examined. Strong influence of the rotating HPC equipment on the CO2 distribution detected is discussed.

  4. Gallium Nitride -based Microwave Power Varactors for Wireless Base Station Applications

    Science.gov (United States)

    Lu, Wei

    With the development of wireless communication systems, the demand for providing tunability in the wireless communication circuits becomes more and more intense. Among the technologies, semiconductor varactor is the critical component that is capable of implementing tunable and adaptive characteristics, particularly for the frond-end components of the wireless communication systems. For base station applications, high voltage handling capability, typically of 100 V or greater, high quality factor (Q), typically of above 100 at operation frequency, and high linearity, OIP3 > 65 dBm, are required. This work will mainly discuss in detail the design, fabrication and characterization to achieve the high-voltage high-Q and high-linearity microwave power varactors for wireless base station applications. Some preliminary varactor applications in the test tunable circuits will be demonstrated too. In this dissertation, we first introduce the physics of the semiconductor varactors and the motivation for choosing GaN as the candidate material for this microwave power varactor. Then we elucidate the critical design considerations for achieving high breakdown voltage, high quality factor and high linearity. The novel Schottky barrier engineered design using a thin InGaN surface layer on top of GaN to enhance the breakdown voltage of GaN-based Schottky diodes is therefore introduced. We then show the theoretical and experimental studies on the suppression mechanisms for electron tunneling in the InGaN/GaN Schottky barriers. The detailed material characterization for the InGaN/GaN material system and its application for the enhancement-mode HEMTs are also presented. Next, we discuss the initial device fabrication procedure and the improving methods based on the initial DC and RF measurement results. Thereafter, we report the detailed characterizations of the fabricated devices including the high-voltage I-V and C-V, S-parameters for 1-port and 2-port devices, linearity and

  5. Forecasting New Hampshire Power Outages through the Analysis of Weather Station Observations

    Science.gov (United States)

    Fessenden, Ross T.

    Eversource Energy, formerly Public Service of New Hampshire (PSNH), has worked closely with Plymouth State University (PSU) in the past, and present, to better predict weather-related power outage events and maximize the efficiency with which Eversource responds to them. This research paired weather data from thirteen stations throughout New Hampshire, Vermont, and Massachusetts with Eversource Trouble Report and Unsatisfactory Performance of Equipment Report (TRUPER) data in an effort to quantify weather situations that lead to power outages. The ultimate goal involved developing a predictive model that uses weather data to forecast the magnitude of power outages. The study focused on the Eversource Western/Central service territory and utilized data from 2006-2010. The first four years, 2006-2009, were analyzed using Classification and Regression Tree (CART) statistical analysis. The results of this CART analysis trained a predictive model, while the fifth year, 2010, served as the testing set for the predictive model. To conduct the statistical analysis, a database was created pairing TRUPER reports with the closest available hourly weather observations. The database included nine weather variables matched with three variables from the TRUPER data: 1) customers, 2) customer minutes, and 3) outage duration. While the entire Eversource service territory saw 91,286 TRUPERs from 2006-2010, the Western/Central service territory, the focus of this study, accounted for 29,430. Before conducting the CART analysis, correlations between single weather variables and TRUPER data were calculated and, in general, proved xi weak. In addition to analyzing the complete four-year training data set, many portions/variations of the data set were analyzed. The analyses included a yearly analysis, time lag analysis, cold/warm-season analysis, and a single-station analysis. Although individual years and smaller data sets showed moderately higher correlations between weather and outage

  6. Fundamental assumptions for development of small water power stations and resulting indications for standarization of their generating sets

    Energy Technology Data Exchange (ETDEWEB)

    Hoffmann, M.

    1983-01-01

    According to the criterion of simple technical construction and no regular personnel, the concept of Small Water Power Stations (SWPS) covers power stations with output capacity less than 5 MW. It follows that for economical reasons these plants should: make use of so far existing dams with total head greater than or equal to 3 m, and have simple technical solutions (1 generating set with high rotating speed and no high voltage switchboard). It is assumed that SWPS will consist mostly of flow power plants capable to operate in their own network. It is suggested that 950 SWPS with Kaplan turbines in concrete chambers or vertical and horizontal pipe turbines (H greater than or equal to 20 m) and 70 power stations with Francis turbines (H > 20 m) should be put in operation by 2000. Some results of a review, carried out recently in Poland, of structures suitable for installing small water power stations are presented. Also, some of the most important foreign companies manufacturing water turbines of small capacity are specified.

  7. A novel concentrator with zero-index metamaterial for space solar power station

    Science.gov (United States)

    Huang, Jin; Chu, Xue-mei; Fan, Jian-yu; Jin, Qi-bao; Duan, Zhu-zhu

    2017-03-01

    Space solar power station (SSPS) is a comprehensive system that continuously collects solar energy in space and transmits it to ground with a wireless power transmission (WPT) system. These systems have great potential to provide large-scale energy. To increase the efficiency and reduce the weight and cost of the photovoltaic (PV) components, a huge light-weighted concentrator was introduced in the latest SSPS concepts, such as integrated symmetrical concentrator (ISC) and arbitrarily large phased array (ALPHA). However, for typical SSPS running in Geostationary Earth Orbit (GEO), the sunlight direction varies with time, leading to a great challenge for concentrator design. In ISC, the two-dimensional mast is used to realize sun-tracking. However, a multi-thousand-ton structure is difficult to control precisely in space. For this reason, ALPHA comprises a large number of individually pointed thin-film reflectors to intercept sunlight, mounted on the non-moving structure. However, the real-time adjustment of the thousands of reflectors is still an open problem. Furthermore, the uniformity of the time of the power generation (UTPG) is another factor evaluating the system. Therefore, this paper proposes a novel concentrator based on zero-index metamaterial (ZIM) called Thin-film Energy Terminator (SSPS-TENT). This will aid the control of the massive reflectors while avoiding the rotation of the overall system, the control of the massive reflectors and the influence of the obliquity of the ecliptic. Also, an optimization design method is proposed to increase its solar energy collecting efficiency (ECE) and flux distribution (FD). The ray-tracing simulation results show that the ECE is more than 96% of the day. In terms of the FD, the uniformity varies from 0.3057 to 0.5748. Compared with ALPHA, the UTPG is more stable.

  8. Report of examination of the ruptured pipe at the Hamaoka Nuclear Power Station Unit-1

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-12-01

    In order to investigate root cause of the pipe rupture, which took place at the Hamaoka Nuclear Power Station Unit-1 of Chubu Electric Power Company on November 7, 2001, a task force was established within the Nuclear and Industrial Safety Agency (NISA) and initiated a detailed investigation of the ruptured pipe. The Japan Atomic Energy Research Institute (JAERI) was asked from the Ministry of Education, Culture, Sports, Science and Technology (MEXT) in response to the request from NISA to cooperate as an independent neutral organization with NISA and perform an examination of the ruptured pipe independently from Chubu Electric Power Company. JAERI accepted the request by considering the fact that JAERI is an integrated research institution for nuclear research and development, a prime research institution for nuclear safety research, a research institution with experience of root-cause investigation of various nuclear incidents and accidents of domestic as well as overseas, and a research institution provided with advanced examination facilities necessary for examination of the ruptured pipe. The JAERI examination group was formed at the Tokai Research Establishment and conducted detailed and thorough examination of the pieces taken from the ruptured pipe primarily in the Reactor Fuel Examination Facility (RFEF) with the use of tools such as scanning electron microscopes and other equipments. Purpose of examination was to provide technical information in order to identify causes of the pipe rupture through examination of the pieces taken from the ruptured region of the pipe. The following findings and conclusion were made as the result of the present examination. (1) Wall thickness of the pipe was significantly reduced in the ruptured region. (2) Dimple pattern resulting from ductile fracture by shearing was observed in the fracture surfaces of nearly all of the pieces and no indication of fatigue crack growth was found. (3) Microstructure showed a typical carbon

  9. Second periodic safety review of Angra Nuclear Power Station, unit 1

    Energy Technology Data Exchange (ETDEWEB)

    Martins, Carlos F.O.; Crepaldi, Roberto; Freire, Enio M., E-mail: ottoncf@tecnatom.com.br, E-mail: emfreire46@gmail.com, E-mail: robcrepaldi@hotmail.com [Tecnatom do Brasil Engenharia e Servicos Ltda, Rio de Janeiro, RJ (Brazil); Campello, Sergio A., E-mail: sacampe@eletronuclear.gov.br [Eletrobras Termonuclear S.A. (ELETRONUCLEAR), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    This paper describes the second Periodic Safety Review (PSR2-A1) of Angra Nuclear Power Station, Unit 1, prepared by Eletrobras Eletronuclear S.A. and Tecnatom do Brasil Engenharia e Servicos Ltda., during Jul.2013-Aug.2014, covering the period of 2004-2013. The site, in Angra dos Reis-RJ, Brazil, comprises: Unit 1, (640 MWe, Westinghouse PWR, operating), Unit 2 (1300 MWe, KWU/Areva, operating) and Unit 3 (1405 MWe, KWU/Areva, construction). The PSR2-A1 attends the Standards 1.26-Safety in Operation of Nuclear Power Plants, Brazilian Nuclear Regulatory Commission (CNEN), and IAEA.SSG.25-Periodic Safety Review of Nuclear Power Plants. Within 18 months after each 10 years operation, the operating organization shall perform a plant safety review, to investigate the evolution consequences of safety code and standards, regarding: Plant design; structure, systems and components behavior; equipment qualification; plant ageing management; deterministic and probabilistic safety analysis; risk analysis; safety performance; operating experience; organization and administration; procedures; human factors; emergency planning; radiation protection and environmental radiological impacts. The Review included 6 Areas and 14 Safety Parameters, covered by 33 Evaluations.After document evaluations and discussions with plant staff, it was generated one General and 33 Specific Guide Procedures, 33 Specific and one Final Report, including: Description, Strengths, Deficiencies, Areas for Improvement and Conclusions. An Action Plan was prepared by Electronuclear for the recommendations. It was concluded that the Unit was operated within safety standards and will attend its designed operational lifetime, including possible life extensions. The Final Report was submitted to CNEN, as one requisite for renewal of the Unit Permanent Operation License. (author)

  10. Optimal Dispatch Strategy of a Virtual Power Plant Containing Battery Switch Stations in a Unified Electricity Market

    Directory of Open Access Journals (Sweden)

    Hao Bai

    2015-03-01

    Full Text Available A virtual power plant takes advantage of interactive communication and energy management systems to optimize and coordinate the dispatch of distributed generation, interruptible loads, energy storage systems and battery switch stations, so as to integrate them as an entity to exchange energy with the power market. This paper studies the optimal dispatch strategy of a virtual power plant, based on a unified electricity market combining day-ahead trading with real-time trading. The operation models of interruptible loads, energy storage systems and battery switch stations are specifically described in the paper. The virtual power plant applies an optimal dispatch strategy to earn the maximal expected profit under some fluctuating parameters, including market price, retail price and load demand. The presented model is a nonlinear mixed-integer programming with inter-temporal constraints and is solved by the fruit fly algorithm.

  11. Ground based observations of Pc3-Pc5 geomagnetic pulsation power at Antarctic McMurdo station

    Directory of Open Access Journals (Sweden)

    C. G. Maclennan

    1998-06-01

    Full Text Available The two horizontal geomagnetic components and, measured by a fluxgate magnetometer at Antarctic McMurdo station (corrected geomagnetic coordinates 80.0° S, 327.5° E, are analyzed for the period May-June 1994; the spectral powers are calculated and integrated over three frequency intervals corresponding to the nominal ranges. The time dependence of those integrated powers and their correlations with northern auroral indices and solar wind speed are considered. The observations are compared with previous results reported from Terra Nova Bay station (located near McMurdo at the same corrected geomagnetic latitude during Antarctic summer intervals. The differences found between the two stations are discussed in terms of the seasonal dependence of geomagnetic field line configurations in the near cusp region.

  12. Measurement of the Magnetic Properties of P9 and T22 Steel Taken from Service in Power Station

    OpenAIRE

    Wilson, JWa; Karimian, N a; Liu, J. B.; Yin, W a; Davis, CLb; Peyton, AJa

    2014-01-01

    With the UK's aging power generation network, life-extension of steel plant components is a critical issue. However, in order to evaluate the likelihood of component failure, techniques must be developed to properly assess the level of degradation in power station steels. Electromagnetic inspection has the potential to quantify the level of degradation through in-situ measurements at elevated temperatures. This paper reports the results of tests carried out on thermally treated P9 and T22 ste...

  13. Assessing the relationship between leadership styles, coping and employee attitudes at a power station / Mthunzi Freedom Lushozi

    OpenAIRE

    Lushozi, Mthunzi Freedom

    2014-01-01

    The study was conducted to assess the state of leadership characteristics and the impact these variables have on employee self-esteem and employee work-related outcomes in a South African power utility in particular power station environment. The inquiry was conducted in a natural working environment of an organisation where respondents are situated/ located (i.e. a field study). A stratified convenience sampling approach was used to carry out the study using a structured questionnaire develo...

  14. Technology, safety and costs of decommissioning a Reference Boiling Water Reactor Power Station. Main report. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Oak, H.D.; Holter, G.M.; Kennedy, W.E. Jr.; Konzek, G.J.

    1980-06-01

    Technology, safety and cost information is given for the conceptual decommissioning of a large (1100MWe) boiling water reactor (BWR) power station. Three approaches to decommissioning, immediate dismantlement, safe storage with deferred dismantlement and entombment, were studied to obtain comparisons between costs, occupational radiation doses, potential dose to the public and other safety impacts. It also shows the sensitivity of decommissioning safety and costs to the power rating of a BWR in the range of 200 to 1100 MWe.

  15. Building of Analytic Model for ST-35-90/10 Turbine Energy Characteristic at the Vitebsk Thermal Power Station

    Directory of Open Access Journals (Sweden)

    Y. B. Popova

    2007-01-01

    Full Text Available The paper contains a methodology of building an analytical model for an ST-35-90/10 extraction turbine with two regulated extractions at the Vitebsk Thermal Power Station. This methodology makes it possible to decrease the time for mode calculation. The obtained characteristic can be used for solution of optimization problems.

  16. Addressing Obsolescence in Operating Power Stations by Implementation of Safety Related Digital Upgrades Paper for Spanish Nuclear Society

    Energy Technology Data Exchange (ETDEWEB)

    Legrand, R.

    2014-07-01

    Obsolescence of Instrumentation and Controls is a major problem facing operating Nuclear Power Stations globally. AREVA is the only supplier that has supported the successful licensing, engineering, procurement, installation and commissioning of a full-scope digital Instrumentation and Control (I and C) Protection System in the United States. (Author)

  17. 78 FR 79017 - Zion Solutions, LLC; Zion Nuclear Power Station, Units 1 and 2; Exemption From Certain Physical...

    Science.gov (United States)

    2013-12-27

    ... COMMISSION Zion Solutions, LLC; Zion Nuclear Power Station, Units 1 and 2; Exemption From Certain Physical... shut down facility and responsibility for its decommissioning was transferred to ZionSolutions (ZS), a subsidiary of EnergySolutions. ZS was established solely for the purpose of acquiring and decommissioning...

  18. On the building of Momoyama hydraulic power station on Kiso river. Kisogawa Momoyama suiryoku hatsudensho no kenchiku ni tsuite

    Energy Technology Data Exchange (ETDEWEB)

    Kotera, T. (Nagoya University, Nagoya (Japan). Faculty of Engineering)

    1991-09-30

    This paper investigates Momoyama hydraulic power station built on the middle reaches of the Kiso River in Uematsu-cho, Kiso-gun, Nagano Prefecture in Japan, in 1923 by relating to the feature of the building of the hydraulic power station and the architect, Shiro Sato. The hydraulic power station originally was a functional and industrial building which puts a priority on the efficiency of business economy, at the same time it was often required to present a beautiful appearance. The building of Momoyama hydraulic power station was founded on the crane girder structure covered with reinforced concrete(RC) walls. A Hat roof of RC slab was applied to the roof of the building. It was generally designed in Neo-Gothic style. More specifically, however, the wall surface was designed in church style and the upper part was like a castle in the middle ages. Therefore the total design was eclectic. The outer surfaces of the building were remained to be bare concrete as cast. Such a multiple building symbolizes the situation of Japanes architecture in the 1920s. 4 figs.

  19. 75 FR 10833 - In the Matter of Entergy Nuclear Operations; Vermont Yankee Nuclear Power Station; Demand for...

    Science.gov (United States)

    2010-03-09

    ... From the Federal Register Online via the Government Publishing Office NUCLEAR REGULATORY COMMISSION In the Matter of Entergy Nuclear Operations; Vermont Yankee Nuclear Power Station; Demand for... this Demand for Information, the following information, in writing, and under oath or affirmation: 1...

  20. THE YOUNG OPEN CLUSTER BERKELEY 55

    Energy Technology Data Exchange (ETDEWEB)

    Negueruela, Ignacio; Marco, Amparo, E-mail: ignacio.negueruela@ua.es, E-mail: amparo.marco@ua.es [Departamento de Fisica, Ingenieria de Sistemas y Teoria de la Senal, Universidad de Alicante, Apdo. 99, E-03080 Alicante (Spain)

    2012-02-15

    We present UBV photometry of the highly reddened and poorly studied open cluster Berkeley 55, revealing an important population of B-type stars and several evolved stars of high luminosity. Intermediate-resolution far-red spectra of several candidate members confirm the presence of one F-type supergiant and six late supergiants or bright giants. The brightest blue stars are mid-B giants. Spectroscopic and photometric analyses indicate an age 50 {+-} 10 Myr. The cluster is located at a distance d Almost-Equal-To 4 kpc, consistent with other tracers of the Perseus Arm in this direction. Berkeley 55 is thus a moderately young open cluster with a sizable population of candidate red (super)giant members, which can provide valuable information about the evolution of intermediate-mass stars.

  1. Berkeley Lab Computing Sciences: Accelerating Scientific Discovery

    OpenAIRE

    Hules, John A.

    2009-01-01

    Scientists today rely on advances in computer science, mathematics, and computational science, as well as large-scale computing and networking facilities, to increase our understanding of ourselves, our planet, and our universe. Berkeley Lab's Computing Sciences organization researches, develops, and deploys new tools and technologies to meet these needs and to advance research in such areas as global climate change, combustion, fusion energy, nanotechnology, biology, and astrophysics.

  2. Lawrence Berkeley Laboratory 1993 Site Environmental Report

    Energy Technology Data Exchange (ETDEWEB)

    1994-05-01

    This annual Site Environmental Report summarizes Lawrence Berkeley Laboratory`s (LBL`s) environmental activities in calendar year (CY) 1993. The purpose of this report is to characterize site environmental management performance, confirm compliance status with environmental standards and requirements, and highlight significant programs and efforts. Its format and content are consistent with the requirements of the US Department of Energy (DOE) Order 5400.1, General Environmental Protection Program.

  3. Complex use of waste in wastewater and circulating water treatment from oil in heat power stations

    Science.gov (United States)

    Nikolaeva, L. A.; Iskhakova, R. Ya.

    2017-06-01

    Sewage and circulating water from oil of thermal power plants (TPP) generated in fuel-oil shops during washing of electrical equipment and its running into the storm drainage system from the industrial site has been considered in the paper. It has been suggested to use the carbonate sludge of water treatment modified with hydrophobing emulsion as a sorption material for waste and circulating water treatment in thermal power plants. The carbonate sludge is waste accumulated in clarifiers at the stage of natural water pretreatment. General technical characteristics of the sludge, such as moisture, bulk density, total pore volume, ash, etc., have been determined. It has been found that the sludge without additional treatment is a hydrophilic material that has low adsorption capacity and wettability with nonpolar compounds. Therefore, the sludge is treated with organosilicon compounds to reduce the moisture capacity and increase its floatation. Several types of sorption materials based on the carbonate sludge subjected to surface and volume hydrophobization have been developed. During the volume treatment, the hydrophobing compound has been introduced into the material along with the plastifier. In case of the surface treatment, heat-treated granules have been soaked into hydrophobing emulsion. It has been shown that surface hydrophobization is most economically advantageous, because it reduces the consumption of water-repelling agent, wherein the total pore volume and sorption capacity during surface hydrophobization increase by 45 and 25% compared to that during volume hydrophobization. Based on the obtained results, the most effective sorption material has been chosen. To produce this material, it is necessary to sequentially carry out mixing of carbonate sludge with the binder, granulation, calcination, impregnation with a waterrepellent emulsion, and drying of the finished material. The suggested technology to produce the material and use it as a sorbent allows

  4. Trace elements in solid waste products from coal burning at some Bulgarian thermoelectric power stations

    Energy Technology Data Exchange (ETDEWEB)

    Vassilev, S.V. [Bulgarian Academy of Sciences, Sofia (Bulgaria). Institute of Applied Mineralogy

    1994-03-01

    The content, concentration trend and mode of occurrence of 40 trace elements in coal mixtures (coals and host rocks), fly ash, bottom ash and lagooned ash at four Bulgarian thermoelectric power stations (TPS) have been characterized. A complex of methods: separation, atomic emission and ICP spectroscopy, neutron activation, XRF, SEM, TEM, XRD, etc., was used. Trace elements in coal mixtures are concentrated mainly in the heavy fractions (above 2.9 g cm{sup -3}), authigenic minerals and organic matter; and to a lesser extent are present in the major detrital minerals and host rocks. A number of elements in the waste products, like coal mixtures (ash), exceed known Clarke contents. These are mostly the siderophilic, some lithophilic (Rb, Nb, Mo, Ba, REE, Hf) and chalcophilic (Cu, Zn, As) elements and U. The trace elements show different concentration trends in fly ash, but are more typical for non-magnetic, heavy and fine-grained fractions. They are commonly present as impurities in the glass phases, and are included in the structure of mineral phases. The accessory crystalline phases, element-organic compounds, liquid and gas forms, are of subordinate importance. Some elements, mostly from the chalcophilic (Cu, Zn, Ga, As, Sn, Sb) and lithophilic (Be, Y, Zr, Nb, Mo) groups, plus Co and U, show scattering trends into the atmosphere. For others, the combustion process appears to be a powerful factor causing relative increase in the fly ash. Considerable amounts of trace elments from stack emissions (Hf, As, Tl, Pb, etc.) have probably entered the soil near TPS. Trace elements can also occur in watersoluble forms (Li, Mo, Cs, halogen elements, V, As, Bi, etc.) in waste products and accumulate (Sr, Ba, Pb, etc.) in dump vegetation. 35 refs., 5 tabs.

  5. Rancang Bangun Maximum Power Point Tracking pada Panel Photovoltaic Berbasis Logika Fuzzy di Buoy Weather Station

    Directory of Open Access Journals (Sweden)

    Bayu Prima Juliansyah Putra

    2013-09-01

    Full Text Available Salah satu aplikasi yang sering digunakan dalam bidang energi terbarukan adalah panel photovoltaic. Panel ini memiliki prinsip kerja berdasarkan efek photovoltaic dimana lempengan logam akan menghasilkan energi listrik apabila diberi intensitas cahaya. Untuk menghasilkan daya keluaran panel yang maksimal, maka diperlukan suatu algoritma yang biasa disebut Maximum Power Point Tracking (MPPT.MPPT yang diterapkan pada sistem photovoltaic berfungsi untuk mengatur nilai tegangan keluaran panel sehingga titik ker-janya beroperasi pada kondisi maksimal. Algoritma MPPT pada panel ini telah dilakukan dengan menggunakan logika fuzzy melalui mikrokontroler Arduino Uno sebagai pem-bangkit sinyal Pulse Width Modulation (PWM yang akan dikirimkan menuju DC-DC Buck Boost Converter. Keluaran dari buck boost converterakan dihubungkan secara langsung dengan buoy weather station untuk menyuplai energi listrik tiap komponen yang berada di dalamnya. Untuk menguji performansi dari algoritma MPPT yang telah dirancang, maka sistem akan diuji menggunakan variasi beban antara metode direct-coupled dengan MPPT menggunakan logika fuzzy. Hasil pengujian menunjukkan bahwa MPPT dengan logika fuzzy dapat menghasilkan daya maksimum daripada direct-coupled. Pada sistem panel photovoltaic ini memiliki range efisiensi 33.07589 % hingga 74.25743 %. Daya mak-simal dapat dicapai oleh sistem untuk tiap variasi beban dan efisiensi maksimal dapat dicapai pada beban 20 Ohm dari hasil pengujian sistem MPPT.

  6. Microbiological Contamination at Workplaces in a Combined Heat and Power (CHP Station Processing Plant Biomass

    Directory of Open Access Journals (Sweden)

    Justyna Szulc

    2017-01-01

    Full Text Available The aim of the study was to evaluate the microbial contamination at a plant biomass processing thermal power station (CHP. We found 2.42 × 103 CFU/m3 of bacteria and 1.37 × 104 CFU/m3 of fungi in the air; 2.30 × 107 CFU/g of bacteria and 4.46 × 105 CFU/g of fungi in the biomass; and 1.61 × 102 CFU/cm2 bacteria and 2.39 × 101 CFU/cm2 fungi in filtering facepiece respirators (FFRs. Using culture methods, we found 8 genera of mesophilic bacteria and 7 of fungi in the air; 10 genera each of bacteria and fungi in the biomass; and 2 and 5, respectively, on the FFRs. Metagenomic analysis (Illumina MiSeq revealed the presence of 46 bacterial and 5 fungal genera on the FFRs, including potential pathogens Candida tropicalis, Escherichia coli, Prevotella sp., Aspergillus sp., Penicillium sp.. The ability of microorganisms to create a biofilm on the FFRs was confirmed using scanning electron microscopy (SEM. We also identified secondary metabolites in the biomass and FFRs, including fumigaclavines, quinocitrinines, sterigmatocistin, and 3-nitropropionic acid, which may be toxic to humans. Due to the presence of potential pathogens and mycotoxins, the level of microbiological contamination at workplaces in CHPs should be monitored.

  7. Radiation dose reduction efficiency of buildings after the accident at the Fukushima Daiichi Nuclear Power Station.

    Directory of Open Access Journals (Sweden)

    Satoru Monzen

    Full Text Available Numerous radionuclides were released from the Fukushima Daiichi Nuclear Power Station (F1-NPS in Japan following the magnitude 9.0 earthquake and tsunami on March 11, 2011. Local residents have been eager to calculate their individual radiation exposure. Thus, absorbed dose rates in the indoor and outdoor air at evacuation sites in the Fukushima Prefecture were measured using a gamma-ray measuring devices, and individual radiation exposure was calculated by assessing the radiation dose reduction efficiency (defined as the ratio of absorbed dose rate in the indoor air to the absorbed dose rate in the outdoor air of wood, aluminum, and reinforced concrete buildings. Between March 2011 and July 2011, dose reduction efficiencies of wood, aluminum, and reinforced concrete buildings were 0.55 ± 0.04, 0.15 ± 0.02, and 0.19 ± 0.04, respectively. The reduction efficiency of wood structures was 1.4 times higher than that reported by the International Atomic Energy Agency. The efficiency of reinforced concrete was similar to previously reported values, whereas that of aluminum structures has not been previously reported. Dose reduction efficiency increased in proportion to the distance from F1-NPS at 8 of the 18 evacuation sites. Time variations did not reflect dose reduction efficiencies at evacuation sites although absorbed dose rates in the outdoor air decreased. These data suggest that dose reduction efficiency depends on structure types, levels of contamination, and evacuee behaviors at evacuation sites.

  8. Fiber-distributed Ultra-wideband noise radar with steerable power spectrum and colorless base station.

    Science.gov (United States)

    Zheng, Jianyu; Wang, Hui; Fu, Jianbin; Wei, Li; Pan, Shilong; Wang, Lixian; Liu, Jianguo; Zhu, Ninghua

    2014-03-10

    A fiber-distributed Ultra-wideband (UWB) noise radar was achieved, which consists of a chaotic UWB noise source based on optoelectronic oscillator (OEO), a fiber-distributed transmission link, a colorless base station (BS), and a cross-correlation processing module. Due to a polarization modulation based microwave photonic filter and an electrical UWB pass-band filter embedded in the feedback loop of the OEO, the power spectrum of chaotic UWB signal could be shaped and notch-filtered to avoid the spectrum-overlay-induced interference to the narrow band signals. Meanwhile, the wavelength-reusing could be implemented in the BS by means of the distributed polarization modulation-to-intensity modulation conversion. The experimental comparison for range finding was carried out as the chaotic UWB signal was notch-filtered at 5.2 GHz and 7.8 GHz or not. Measured results indicate that space resolution with cm-level could be realized after 3-km fiber transmission thanks to the excellent self-correlation property of the UWB noise signal provided by the OEO. The performance deterioration of the radar raised by the energy loss of the notch-filtered noise signal was negligible.

  9. Risk Assessment Strategy for Decommissioning of Fukushima Daiichi Nuclear Power Station

    Directory of Open Access Journals (Sweden)

    Akira Yamaguchi

    2017-03-01

    Full Text Available Risk management of the Fukushima Daiichi Nuclear Power Station decommissioning is a great challenge. In the present study, a risk management framework has been developed for the decommissioning work. It is applied to fuel assembly retrieval from Unit 3 spent fuel pool. Whole retrieval work is divided into three phases: preparation, retrieval, and transportation and storage. First of all, the end point has been established and the success path has been developed. Then, possible threats, which are internal/external and technical/societal/management, are identified and selected. “What can go wrong?” is a question about the failure scenario. The likelihoods and consequences for each scenario are roughly estimated. The whole decommissioning project will continue for several decades, i.e., long-term perspective is important. What should be emphasized is that we do not always have enough knowledge and experience of this kind. It is expected that the decommissioning can make steady and good progress in support of the proposed risk management framework. Thus, risk assessment and management are required, and the process needs to be updated in accordance with the most recent information and knowledge on the decommissioning works.

  10. Technology, safety, and costs of decommissioning a reference pressurized water reactor power station

    Energy Technology Data Exchange (ETDEWEB)

    Smith, R.I.; Konzek, G.J.; Kennedy, W.E. Jr.

    1978-05-01

    Safety and cost information was developed for the conceptual decommissioning of a large (1175 MW(e)) pressurized water reactor (PWR) power station. Two approaches to decommissioning, Immediate Dismantlement and Safe Storage with Deferred Dismantlement, were studied to obtain comparisons between costs, occupational radiation doses, potential radiation dose to the public, and other safety impacts. Immediate Dismantlement was estimated to require about six years to complete, including two years of planning and preparation prior to final reactor shutdown, at a cost of $42 million, and accumulated occupational radiation dose, excluding transport operations, of about 1200 man-rem. Preparations for Safe Storage were estimated to require about three years to complete, including 1/sup 1///sub 2/ years for planning and preparation prior to final reactor shutdown, at a cost of $13 million and an accumulated occupational radiation dose of about 420 man-rem. The cost of continuing care during the Safe Storage period was estimated to be about $80 thousand annually. Accumulated occupational radiation dose during the Safe Storage period was estimated to range from about 10 man-rem for the first 10 years to about 14 man-rem after 30 years or more. The cost of decommissioning by Safe Storage with Deferred Dismantlement was estimated to be slightly higher than Immediate Dismantlement. Cost reductions resulting from reduced volumes of radioactive material for disposal, due to the decay of the radioactive containments during the deferment period, are offset by the accumulated costs of surveillance and maintenance during the Safe Storage period.

  11. Outbreak of Legionnaires' disease from a cooling water system in a power station (Heysham)

    Energy Technology Data Exchange (ETDEWEB)

    Morton, S.; Dyer, J.V.; Bartlett, C.L.R.; Bibby, L.F.; Hutchinson, D.N.; Dennis, P.J.

    1986-09-01

    In September and October 1981 six cases of pneumonia occurred among men working in a power station under construction. Three were identified as cases of legionella pneumonia and two others had serology suggestive of legionella infection. In a sample of 92 men from the site 10 had low levels of antibodies to legionella; a similar sample of men working on an adjacent site showed none with positive serology. In a case control study it was found that cases of pneumonia were more likely than controls to have worked on a part of the site where four small capacity cooling towers were located. Legionella pneumophila serogroup 1 was isolated from the water systems of these four towers but was not found in samples from any other cooling towers or hot or cold water outlets on the site. It would appear that there was airborne spread of the organism from these cooling water systems which had not received conventional treatment to inhibit corrosion and organic growth. This is the first outbreak of legionnaires' disease to be recorded in an industrial setting in the United Kingdom. No cases of legionella infection have occurred on the site since the introduction of control measures.

  12. Application of seismic isolation technology to computer system in nuclear power stations

    Energy Technology Data Exchange (ETDEWEB)

    Gunyasu, Kenzou; Takamatsu, Naotaka; Fujimoto, Shigeru; Fukui, Hidehiro (Toshiba Corp., Kawasaki, Kanagawa (Japan))

    1994-08-01

    In the current aseismatic design, the rigid structures that withstand earthquakes by own strength have been adopted. However recently, seismically isolated structures were devised, and begin to be applied to buildings and others. It is characterized by that the basic structures as the object of seismic isolation are not changed, and by using special seismic isolators, the structures are made flexible to avoid the resonance with the eminent period of earthquakes and reduce the earthquake force acting on the structures. As the concrete example of seismic isolation, in Japan, seismically isolated floors have been introduced for the computer centers of banks. Also in nuclear power stations, the application of seismic isolation to computer systems has been considered. The function, constitution, structure and the method of increasing the aseismatic capability of computer system are explained. The function required for seismic isolation floors, the seismic isolation structure of rolling type composed of coil springs, dampers and ball bearings, its principle of action, and the vibration test on the seismic isolation floor are reported. (K.I.).

  13. The network architecture and site test of DCIS in Lungmen nuclear power station

    Energy Technology Data Exchange (ETDEWEB)

    Lee, C. K. [Instrument and Control Section, Lungmen Nuclear Power Station, Taiwan Power Company, Taipei County Taiwan (China)

    2006-07-01

    The Lungmen Nuclear Power Station (LMNPS) is located in North-Eastern Seashore of Taiwan. LMNPP has two units. Each unit generates 1350 Megawatts. It is the first ABWR Plant in Taiwan and is under-construction now. Due to contractual arrangement, there are seven large I and C suppliers/designers, which are GE NUMAC, DRS, Invensys, GEIS, Hitachi, MHI, and Stone and Webster company. The Distributed Control and Information System (DCIS) in Lungmen are fully integrated with the state-of-the-art computer and network technology. General Electric is the leading designer for integration of DCIS. This paper presents Network Architecture and the Site Test of DCIS. The network architectures are follows. GE NUMAC System adopts the point to point architecture, DRS System adopts Ring type architecture with SCRAMNET protocol, Inevnsys system adopts IGiga Byte Backbone mesh network with Rapid Spanning Tree Protocol, GEIS adopts Ethernet network with EGD protocol, Hitachi adopts ring type network with proprietary protocol. MHI adopt Ethernet network with UDP. The data-links are used for connection between different suppliers. The DCIS architecture supports the plant automation, the alarm prioritization and alarm suppression, and uniform MMI screen for entire plant. The Test Program regarding the integration of different network architectures and Initial DCIS architecture Setup for 161KV Energization will be discussed. Test tool for improving site test schedule, and lessons learned from FAT will be discussed too. And conclusions are at the end of this paper. (authors)

  14. Microbiological Contamination at Workplaces in a Combined Heat and Power (CHP) Station Processing Plant Biomass

    Science.gov (United States)

    Szulc, Justyna; Otlewska, Anna; Okrasa, Małgorzata; Majchrzycka, Katarzyna; Sulyok, Michael; Gutarowska, Beata

    2017-01-01

    The aim of the study was to evaluate the microbial contamination at a plant biomass processing thermal power station (CHP). We found 2.42 × 103 CFU/m3 of bacteria and 1.37 × 104 CFU/m3 of fungi in the air; 2.30 × 107 CFU/g of bacteria and 4.46 × 105 CFU/g of fungi in the biomass; and 1.61 × 102 CFU/cm2 bacteria and 2.39 × 101 CFU/cm2 fungi in filtering facepiece respirators (FFRs). Using culture methods, we found 8 genera of mesophilic bacteria and 7 of fungi in the air; 10 genera each of bacteria and fungi in the biomass; and 2 and 5, respectively, on the FFRs. Metagenomic analysis (Illumina MiSeq) revealed the presence of 46 bacterial and 5 fungal genera on the FFRs, including potential pathogens Candida tropicalis, Escherichia coli, Prevotella sp., Aspergillus sp., Penicillium sp.). The ability of microorganisms to create a biofilm on the FFRs was confirmed using scanning electron microscopy (SEM). We also identified secondary metabolites in the biomass and FFRs, including fumigaclavines, quinocitrinines, sterigmatocistin, and 3-nitropropionic acid, which may be toxic to humans. Due to the presence of potential pathogens and mycotoxins, the level of microbiological contamination at workplaces in CHPs should be monitored. PMID:28117709

  15. Design of FPGA Based Neural Network Controller for Earth Station Power System

    Directory of Open Access Journals (Sweden)

    Hassen T. Dorrah

    2012-06-01

    Full Text Available Automation of generating hardware description language code from neural networks models can highly decrease time of implementation those networks into a digital devices, thus significant money savings. To implement the neural network into hardware designer, it is required to translate generated model into device structure. VHDL language is used to describe those networks into hardware. VHDL code has been proposed to implement ANNs as well as to present simulation results with floating point arithmetic of the earth station and the satellite power systems using ModelSim® PE 6.6 simulator tool. Integration between MATLAB® and VHDL is used to save execution time of computation. The results shows that a good agreement between MATLAB and VHDL and a fast/flexible feed forward NN which is capable of dealing with floating point arithmetic operations; minimum number of CLB slices; and good speed of performance. FPGA synthesis results are obtained with view RTL schematic and technology schematic from Xilinix tool. Minimum number of utilized resources is obtained by using Xilinix VERTIX5.

  16. Microbiological Contamination at Workplaces in a Combined Heat and Power (CHP) Station Processing Plant Biomass.

    Science.gov (United States)

    Szulc, Justyna; Otlewska, Anna; Okrasa, Małgorzata; Majchrzycka, Katarzyna; Sulyok, Michael; Gutarowska, Beata

    2017-01-21

    The aim of the study was to evaluate the microbial contamination at a plant biomass processing thermal power station (CHP). We found 2.42 × 10³ CFU/m³ of bacteria and 1.37 × 10⁴ CFU/m³ of fungi in the air; 2.30 × 10⁷ CFU/g of bacteria and 4.46 × 10⁵ CFU/g of fungi in the biomass; and 1.61 × 10² CFU/cm² bacteria and 2.39 × 10¹ CFU/cm² fungi in filtering facepiece respirators (FFRs). Using culture methods, we found 8 genera of mesophilic bacteria and 7 of fungi in the air; 10 genera each of bacteria and fungi in the biomass; and 2 and 5, respectively, on the FFRs. Metagenomic analysis (Illumina MiSeq) revealed the presence of 46 bacterial and 5 fungal genera on the FFRs, including potential pathogens Candida tropicalis, Escherichia coli, Prevotella sp., Aspergillus sp., Penicillium sp.). The ability of microorganisms to create a biofilm on the FFRs was confirmed using scanning electron microscopy (SEM). We also identified secondary metabolites in the biomass and FFRs, including fumigaclavines, quinocitrinines, sterigmatocistin, and 3-nitropropionic acid, which may be toxic to humans. Due to the presence of potential pathogens and mycotoxins, the level of microbiological contamination at workplaces in CHPs should be monitored.

  17. Problems of adhering organisms in power stations. Hatsudensho ni okeru fuchaku seibutsu no mondai

    Energy Technology Data Exchange (ETDEWEB)

    Sakaguchi, Isamu (Central Research Inst. of Electric Power Industry, Tokyo (Japan))

    1989-01-05

    Much seawater is used in thermal power station in Japan to cool condensers but organisms adhered on the water channel system result many troubles such as increase of flowing resistance, reduction of thermal transfer efficiendy, corrosion or erosion-corrosion of condenser pipes, and cleaning difficulty for periodic inspection. Living organisms range from micro bacteria of 2 mum to oysters and others of about 10cm size. For these reasons, the intake open channel is previously designed to larger size and this margin is called the shellfish allowance. Mussels which adhere most on circulating water channels, are one of Bivalvia, grow to 3-6cm and in maximum case to 9cm in a year. These adhere on the surface base by secreting adhesive disc consisting of byssus. Barnacles are one of Crustacea and their larvas search preferable places as to light, roughness and water flow and can adhere on a place in considerably rapid water flow. Other organisms are bacteria and Hydrozoa. Many problems are caused by these organisms even now. 8 refs., 3 figs., 2 tabs.

  18. Utilization direction of industrial raw products built-up in power station ash dumps

    Directory of Open Access Journals (Sweden)

    Lihach Snejana A.

    2017-01-01

    Full Text Available Nowadays hundreds million tons of ash and slag waste (ASW is produced in Russia yearly. Large territories are needed in order to store such a big waste volume. Besides, it is necessary to conduct special engineering and ecological work at the design and usage stages of this structure. The goal of the research is to outline acceptable ASW utilization methods accumulated in coal burning power station ash dumps and to determine the order of activities to solve the problem. The research methods: experimental where Kansk-Achinsk and Kuznetsk coals are the object of the research. Besides, review of relevant to the problem literature and normative documentation was done to determine activities order, possible ways and limitations of the problem solving. We elucidated that ASW transportation to depleted coal quarries to restore them is essential to arrange in order to solve the problem of ASW utilization. As to new produced ASW, they should be divided into groups according to application field (mostly in construction. The groups correspond to boiler unit load operation. After coal combustion ash is stored in special places (reservoirs, silos. Therefore modern boiler unit might be seen as a production complex of steam and ash and slag material of an adequate quality.

  19. Risk assessment strategy for decommissioning of Fukushima Daiichi Nuclear Power Station

    Energy Technology Data Exchange (ETDEWEB)

    Yamaguchi, Akira; Jang, Sung Hoon [The University of Tokyo, Tokyo (Japan); Hida, Kazuki [Nuclear Damage Compensation and Decommissioning Facilitation Corporation, Tokyo (Japan); Yamanaka, Yasunori [Tokyo Electric Power Company Holdings, Tokyo (Japan); Narumiya, Yoshiyuki [The Kansai Electric Power Co., Inc., Osaka (Japan)

    2017-03-15

    Risk management of the Fukushima Daiichi Nuclear Power Station decommissioning is a great challenge. In the present study, a risk management framework has been developed for the decommissioning work. It is applied to fuel assembly retrieval from Unit 3 spent fuel pool. Whole retrieval work is divided into three phases: preparation, retrieval, and transportation and storage. First of all, the end point has been established and the success path has been developed. Then, possible threats, which are internal/external and technical/societal/management, are identified and selected. “What can go wrong?” is a question about the failure scenario. The likelihoods and consequences for each scenario are roughly estimated. The whole decommissioning project will continue for several decades, i.e., long-term perspective is important. What should be emphasized is that we do not always have enough knowledge and experience of this kind. It is expected that the decommissioning can make steady and good progress in support of the proposed risk management framework. Thus, risk assessment and management are required, and the process needs to be updated in accordance with the most recent information and knowledge on the decommissioning works.

  20. Peach Bottom Atomic Power Station recirc pipe dose rates with zinc injection and condenser replacement

    Energy Technology Data Exchange (ETDEWEB)

    DiCello, D.C.; Odell, A.D.; Jackson, T.J. [PECO Energy Co., Delta, PA (United States)

    1995-03-01

    Peach Bottom Atomic Power Station (PBAPS) is located near the town of Delta, Pennsylvania, on the west bank of the Susquehanna River. It is situated approximately 20 miles south of Lancaster, Pennsylvania. The site contains two boiling water reactors of General Electric design and each rated at 3,293 megawatts thermal. The units are BWR 4s and went commercial in 1977. There is also a decommissioned high temperature gas-cooled reactor on site, Unit 1. PBAPS Unit 2 recirc pipe was replaced in 1985 and Unit 3 recirc pipes replaced in 1988 with 326 NGSS. The Unit 2 replacement pipe was electropolished, and the Unit 3 pipe was electropolished and passivated. The Unit 2 brass condenser was replaced with a Titanium condenser in the first quarter of 1991, and the Unit 3 condenser was replaced in the fourth quarter of 1991. The admiralty brass condensers were the source of natural zinc in both units. Zinc injection was initiated in Unit 2 in May 1991, and in Unit 3 in May 1992. Contact dose rate measurements were made in standard locations on the 28-inch recirc suction and discharge lines to determine the effectiveness of zinc injection and to monitor radiation build-up in the pipe. Additionally, HPGe gamma scans were performed to determine the isotopic composition of the oxide layer inside the pipe. In particular, the specific ({mu}Ci/cm{sup 2}) of Co-60 and Zn-65 were analyzed.

  1. Electric Power Plants and Generation Stations, Power Plants mapped and maintained by PR Power Authority, Published in 2009, 1:1200 (1in=100ft) scale, Office of Management and Budget.

    Data.gov (United States)

    NSGIC GIS Inventory (aka Ramona) — This Electric Power Plants and Generation Stations dataset, published at 1:1200 (1in=100ft) scale, was produced all or in part from Field Observation information as...

  2. Design of battery storage power station for power balance%用于电力平衡的蓄电池储能电站的设计

    Institute of Scientific and Technical Information of China (English)

    孟彦京; 刘圆圆; 商晓英

    2013-01-01

    利用蓄电池储能电站调整负荷来保持电力平衡,是解决电力供需矛盾的一种有效途径.建立蓄电池储能电站,蓄电池的选型很重要,因为电池是电站的核心元件.根据机组调峰容量比的概念,建立了调荷容量的数学模型,再结合蓄电池组的调荷容量比,以满足电网综合调荷容量比最小为目标,计算出蓄电池组容量.储能电站的设计中,往往忽略蓄电池连接方式的选择问题,通过多种蓄电池组并串联方案的比较,找出最佳的蓄电池组连接方式,完成锂离子蓄电池储能电站的宏观设计.%It is an effective measure to use battery storage power station to regulate load and keep power balance. For setting up battery storage station, the type selection of batteries which are heart components of the power station is important. The mathematical model of load regulation capacity was built according to the ratio of peak regulation capacity. Then, combined with load regulation capacity ratio of batteries, the capacity of batteries was computed to minimize the integrate load regulation capacity ratio of electricity grid. In design of storage power station, the choice of connection mode is often neglected. Through comparing several schemes of serial-parallel batteries, the best scheme was found to finish the whole design of lithium-ion battery storage power station.

  3. Capacity Calculation of Shunt Active Power Filters for Electric Vehicle Charging Stations Based on Harmonic Parameter Estimation and Analytical Modeling

    Directory of Open Access Journals (Sweden)

    Niancheng Zhou

    2014-08-01

    Full Text Available The influence of electric vehicle charging stations on power grid harmonics is becoming increasingly significant as their presence continues to grow. This paper studies the operational principles of the charging current in the continuous and discontinuous modes for a three-phase uncontrolled rectification charger with a passive power factor correction link, which is affected by the charging power. A parameter estimation method is proposed for the equivalent circuit of the charger by using the measured characteristic AC (Alternating Current voltage and current data combined with the charging circuit constraints in the conduction process, and this method is verified using an experimental platform. The sensitivity of the current harmonics to the changes in the parameters is analyzed. An analytical harmonic model of the charging station is created by separating the chargers into groups by type. Then, the harmonic current amplification caused by the shunt active power filter is researched, and the analytical formula for the overload factor is derived to further correct the capacity of the shunt active power filter. Finally, this method is validated through a field test of a charging station.

  4. Experimental investigations of overvoltages in 6kV station service cable networks of thermal power plants

    Energy Technology Data Exchange (ETDEWEB)

    Vukelja, P.I.; Naumov, R.M.; Drobnjak, G.V.; Mrvic, J.D. [Nikola Tesla Inst., Belgrade (Yugoslavia)

    1996-12-31

    The paper presents the results of experimental investigations of overvoltages on 6kV isolated neutral station service cable networks of thermal power plants. The overvoltages were recorded with capacitive voltage measurement systems made at the Nikola Tesla Institute. Wideband capacitive voltage measurement systems recorded a flat response from below power frequencies to 10MHz. Investigations of overvoltages were performed for appearance and interruption of metal earth faults, intermittent earth faults, switching operation of HV motors switchgear, switching operation of transformers switchgear, and transfer of the network supply from one transformer to another. On the basis of these investigations, certain measures are proposed for limiting overvoltages and for the reliability of station service of thermal power plants.

  5. Probabilistic Physics-Based Risk Tools Used to Analyze the International Space Station Electrical Power System Output

    Science.gov (United States)

    Patel, Bhogila M.; Hoge, Peter A.; Nagpal, Vinod K.; Hojnicki, Jeffrey S.; Rusick, Jeffrey J.

    2004-01-01

    This paper describes the methods employed to apply probabilistic modeling techniques to the International Space Station (ISS) power system. These techniques were used to quantify the probabilistic variation in the power output, also called the response variable, due to variations (uncertainties) associated with knowledge of the influencing factors called the random variables. These uncertainties can be due to unknown environmental conditions, variation in the performance of electrical power system components or sensor tolerances. Uncertainties in these variables, cause corresponding variations in the power output, but the magnitude of that effect varies with the ISS operating conditions, e.g. whether or not the solar panels are actively tracking the sun. Therefore, it is important to quantify the influence of these uncertainties on the power output for optimizing the power available for experiments.

  6. Investigation of potential driver modules and transmission lines for a high frequency power system on the space station

    Science.gov (United States)

    Brush, Harold T.

    1986-01-01

    The feasibility of using Series Resonant Inverter as the driver module for high frequency power system on the Space Station was assessed. The performance of the Series Resonant Inverter that was used in the testing of the single-phase, 2.0-kw resonant AC power system breadboard is summarized. The architecture is descirbed and the driver modules of the 5.0 kw AC power system breadboard are analyzed. An investigation of the various types of transmission lines is continued. Measurements of equivalent series resistor and inductor and equivalent parallel capacitors are presented. In particular, a simplified approach is utilized to describe the optimal transmission line.

  7. Behavior study of trace elements in pulverized lignite, bottom ash, and fly ash of Amyntaio power station, Greece.

    Science.gov (United States)

    Megalovasilis, Pavlos; Papastergios, Georgios; Filippidis, Anestis

    2013-07-01

    The Kozani-Ptolemais-Amyntaio basin constitutes the principal coal field of Greece. Approximately 50% of the total power production of Greece is generated by five power stations operating in the area. Lignite samples, together with the corresponding fly ash and bottom ash were collected, over a period of 3 months, from the power plant of Amyntaio and analyzed for their content in 16 trace elements. The results indicate that Y, Nb, U, Rb, Zr, Ni, Pb, Ba, Zn, Sr, Cu, and Th demonstrate an organic affinity during the combustion of lignite, while V has an inorganic affinity. Three elements (Co, Cr, and Sc) show an intermediate affinity.

  8. A comprehensive approach to selecting the water chemistry of the secondary coolant circuit in the projects of nuclear power stations equipped with VVER-1200 reactors

    Science.gov (United States)

    Tyapkov, V. F.

    2011-05-01

    The paper presents the results obtained from studies on selecting the water chemistry of the secondary coolant circuit carried out for the project of a nuclear power station equipped with a new-generation VVER-1200 reactor on the basis of case calculations and an analysis of field experience gained at operating nuclear power stations.

  9. Station blackout at nuclear power plants: Radiological implications for nuclear war

    Energy Technology Data Exchange (ETDEWEB)

    Shapiro, C.S.

    1986-12-01

    Recent work on station blackout is reviewed its radiological implications for a nuclear war scenario is explored. The major conclusion is that the effects of radiation from many nuclear weapon detonations in a nuclear war would swamp those from possible reactor accidents that result from station blackout.

  10. OFFSET - RAY TRACING OPTICAL ANALYSIS OF OFFSET SOLAR COLLECTOR FOR SPACE STATION SOLAR DYNAMIC POWER SYSTEM

    Science.gov (United States)

    Jefferies, K.

    1994-01-01

    OFFSET is a ray tracing computer code for optical analysis of a solar collector. The code models the flux distributions within the receiver cavity produced by reflections from the solar collector. It was developed to model the offset solar collector of the solar dynamic electric power system being developed for Space Station Freedom. OFFSET has been used to improve the understanding of the collector-receiver interface and to guide the efforts of NASA contractors also researching the optical components of the power system. The collector for Space Station Freedom consists of 19 hexagonal panels each containing 24 triangular, reflective facets. Current research is geared toward optimizing flux distribution inside the receiver via changes in collector design and receiver orientation. OFFSET offers many options for experimenting with the design of the system. The offset parabolic collector model configuration is determined by an input file of facet corner coordinates. The user may choose other configurations by changing this file, but to simulate collectors that have other than 19 groups of 24 triangular facets would require modification of the FORTRAN code. Each of the roughly 500 facets in the assembled collector may be independently aimed to smooth out, or tailor, the flux distribution on the receiver's wall. OFFSET simulates the effects of design changes such as in receiver aperture location, tilt angle, and collector facet contour. Unique features of OFFSET include: 1) equations developed to pseudo-randomly select ray originating sources on the Sun which appear evenly distributed and include solar limb darkening; 2) Cone-optics technique used to add surface specular error to the ray originating sources to determine the apparent ray sources of the reflected sun; 3) choice of facet reflective surface contour -- spherical, ideal parabolic, or toroidal; 4) Gaussian distributions of radial and tangential components of surface slope error added to the surface normals at

  11. Usability value and heavy metals accumulation in forage grasses grown on power station ash deposit

    Directory of Open Access Journals (Sweden)

    Simić Aleksandar S.

    2015-01-01

    Full Text Available The study of five forage grasses (Lolium multiflorum, Festuca rubra, Festuca arundinacea, Arrhenatherum elatius and Dactylis glomerata was conducted on an uncontaminated cultivated land, of leached chernozem type, and on “Nikola Tesla A” (TENT A thermal power station ash deposit. The concentrations of: As, Pb, Cd, Zn, Ni, Fe i Cu in grasses grown on two media were compared. Grass samples have been collected in tillering stage, when they were in full development. During the vegetative period three replications cut was conducted at about 3-5 cm height, imitating mowing and grazing. The concentrations of As and Ni were elevated in media samples collected from TENT A ash deposit, while the level of all studied elements in soil samples collected from cultivated land were within allowed limits. The variance of certain elements amounts in plant material collected from TENT A ash deposit was less homogeneous; the concentrations of As, Fe and Ni were higher in grasses collected from ash deposit, but Pb and Cu concentrations were higher in grasses grown on cultivated land. The concentrations of Zn were approximately the same in plants collected from the sites, whereas Cd concentrations were slightly increased in grasses grown on ash deposit. In general, it can be concluded from the results of this study that the concentrations of heavy metals in plants collected from both sites do not exceed maximal tolerant levels for fodder. The use of grasses grown on ash deposit for forage production should be taken with reserve. [Projekat Ministarstva nauke Republike Srbije, br. TR 31016: Unapređenje tehnologije gajenja krmnih biljaka na oranicama i travnjacima

  12. Treatment of IGCC power station effluents by physico-chemical and advanced oxidation processes.

    Science.gov (United States)

    Durán, A; Monteagudo, J M; Sanmartín, I; García-Peña, F; Coca, P

    2009-03-01

    The aim of this work was to improve the quality of aqueous effluents coming from the Gasification Unit in an Integrated Gasification Combined Cycle (IGCC) Thermoelectric Power Station, with the purpose of fulfilling the future more demanding normative. To this end, an integral wastewater treatment including coagulation, flocculation, neutralization, photocatalytic oxidation, and ion-exchange has been studied. A final scheme has been proposed to remove pollutants. All the parameters of the treated wastewater are below pouring specifications. In the first stage, the wastewater was treated with CaCl2 (optimal dose=11 g CaCl2/g F-) as coagulant and a commercial anionic polyelectrolyte (optimal dose=0.02 g/g F-) as flocculant to remove fluoride ions (99%) and suspended solids (92%). The water was then neutralized, improving the degree of transmission of ultraviolet light, allowing the faster photo-degradation of pollutants. The photochemical study included different systems (H2O2, UV/H2O2, Fenton, Fenton-like, UV/Fenton, UV/Fenton-like and UV/H2O2/O2). In the Fenton-like system, the influence of two parameters (initial concentration of H2O2 and amount of Cu(II)) on the degradation of cyanide and formate (taken as the reference of the process) was studied. Experimental results were fit using neural networks (NNs). Results showed that the photocatalytic process was effective for total cyanide destruction after 60 min, while 180 min was needed to remove 80% of formates. However, a more simple system with UV/H2O2/O2 yields similar results and is preferred for industrial application due to fewer complications. Finally, an ion-exchange process with Amberlite IRA-420 was proposed to remove the excess of chlorides added as a consequence of the initial coagulation process.

  13. Results of the first year of operation at Embalse Nuclear Power Station in Argentina

    Energy Technology Data Exchange (ETDEWEB)

    Bonino, A.; Pizarro, L.; Higa, Z. [Ente Nacional Regulador Nuclear, Buenos Aires (Argentina); Dupree, S.A.; Schoeneman, J.L. [Sandia National Labs., Albuquerque, NM (United States)

    1996-07-16

    As a part of the International Remote Monitoring Project, during March 1995, a Remote Monitoring System (RMS) was installed at the Embalse Nuclear Power Station in Embalse, Argentina. This system monitors the status of four typical Candu spent fuel dry storage silos. The monitoring equipment for each silo consists of analog sensors for temperature and gamma radiation measurement; digital sensors for motion detection; and electronic fiber-optic seals. The monitoring system for each silo is connected to a wireless Authenticate Item Monitoring System (AIMS). This paper describes the operation of the RMS during the first year of the trial and presents the results of the signals reported by the system compared with the on site inspections conducted by the regulatory bodies, ABACC, IAEA, ENREN. As an additional security feature, each sensor periodically transmits authenticated State-of-Health (SOH) messages. This feature provides assurance that all sensors are operational and have not been tampered with. The details of the transmitted information and the incidents of loss of SOH, referred to as Missing SOH Event, and the possible causes which produced the MSOHE are described. The RMS at the embalse facility uses gamma radiation detectors in a strong radiation field of spent fuel dry storage silos. The detectors are Geiger Muller tubes and Silicon solid state diodes. The study of the thermal drift of electronics in GM detectors and the possible radiation damage in silicon detectors is shown. Since the initial installation, the system has been successfully interrogated from Buenos Aires and Albuquerque. The experience gained, and the small changes made in the hardware in order to improve the performance of the system is presented.

  14. Effects of interactions between stations on the calculation of geomagnetically induced currents in an electric power transmission system

    Science.gov (United States)

    Pirjola, R.

    2008-07-01

    "Geomagnetically induced currents" (GIC) in ground-based technological networks are a manifestation of space weather. GIC are a potential source of problems to the systems and therefore important in practice. GIC in a power system (or in principle in any other discretely-earthed system) can be calculated conveniently by using matrix equations presented earlier. Since temporal variations associated with GIC are slow compared to the 50/60 Hz frequency used in power transmission, a dc treatment is acceptable. An essential quantity in calculations of GIC in a power grid is the earthing impedance matrix, which is the transfer function coupling GIC flowing to (from) the Earth with the voltages between the earthing points, called nodes or (sub)stations, and a remote earth. The diagonal elements of the matrix equal the earthing resistances of the nodes whereas an off-diagonal element expresses how much GIC at one earthing point affects the voltage at another node. In GIC calculations, except for some special treatments of individual sites, the off-diagonal elements are usually neglected by saying simply that the earthing points (are assumed to) lie distantly enough. In this paper, we examine the effects of off-diagonal elements of the earthing impedance matrix, i.e. the effects of interactions between different stations, on GIC calculations in greater detail and more quantitatively than before. We consider a fictitious system that represents a high-voltage power grid and a simple "network" consisting of two stations with a line connecting them. For both systems, the conclusion can be drawn that the off-diagonal elements do not play a major role in practice. Modelling them only approximately, or even ignoring them, is not of great significance compared to other shortcomings involved in GIC calculations. This is particularly true when looking at a power grid as a whole although at some individual stations the neglect may lead to larger errors in GIC values.

  15. Test and evaluation of load converter topologies used in the Space Station Freedom power management and distribution dc test bed

    Science.gov (United States)

    Lebron, Ramon C.; Oliver, Angela C.; Bodi, Robert F.

    1991-01-01

    Power components hardware in support of the Space Station freedom dc Electric Power System were tested. One type of breadboard hardware tested is the dc Load Converter Unit, which constitutes the power interface between the electric power system and the actual load. These units are dc to dc converters that provide the final system regulation before power is delivered to the load. Three load converters were tested: a series resonant converter, a series inductor switch-mode converter, and a switching full-bridge forward converter. The topology, operation principles, and test results are described, in general. A comparative analysis of the three units is given with respect to efficiency, regulation, short circuit behavior (protection), and transient characteristics.

  16. Test and evaluation of load converter topologies used in the Space Station Freedom power management and distribution dc test bed

    Science.gov (United States)

    Lebron, Ramon C.; Oliver, Angela C.; Bodi, Robert F.

    1991-01-01

    Power components hardware in support of the Space Station freedom dc Electric Power System were tested. One type of breadboard hardware tested is the dc Load Converter Unit, which constitutes the power interface between the electric power system and the actual load. These units are dc to dc converters that provide the final system regulation before power is delivered to the load. Three load converters were tested: a series resonant converter, a series inductor switch-mode converter, and a switching full-bridge forward converter. The topology, operation principles, and test results are described, in general. A comparative analysis of the three units is given with respect to efficiency, regulation, short circuit behavior (protection), and transient characteristics.

  17. Conditioning of cooling water in power stations. Feedback from twenty years of experience with acid feeding

    Energy Technology Data Exchange (ETDEWEB)

    Goffin, C.; Duvivier, L.; Girasa, E. [LABORELEC, Chemistry of Water (Belgium); Brognez, J. [ELECTRABEL, TIHANGE Nuclear Power Station (Belgium)

    2002-07-01

    In the late 1970's and early 1980's, with the development of the nuclear programme in many European countries, the recirculation of cooling water in power stations became an issue which required urgent attention. The concentration of several plants of 1000 MW or more on sites along inland waterways actually made simple once-through cooling impossible, owing to the risk of an unacceptable rise in the river's water temperature. The chemical composition of natural freshwater in western European waterways is such that when it becomes slightly concentrated, scale is rapidly formed. The relatively low solubility of calcium carbonate and the degassing of the carbon dioxide during close contact between the water and air in the heat exchangers of the cooling tower explain this precipitation tendency. Fairly soon, experts in the electricity power generation companies highlighted the need for on-site, pilot loop simulations, in order to foresee the physico-chemical phenomena that could arise in industrial installations. The number of financially justifiable processing possibilities could be briefly summarised by the following three solutions: to adapt the concentration factor in order to be under the calcium carbonate solubility limit and thereby avoid the need for any water conditioning; to accept concentration factors of between 1.4 and 1.9 and control the calcium carbonate precipitation through controlled acid injection in the circulation water; to raise the concentration factor over 5 and soften the makeup water through the addition of lime and flocculant. The last of these solutions was rarely ever used in Belgium and France. It was however widely used in Germany. Its application requires a greater investment and leads to higher operating costs than acid injection. Furthermore, it leads to the problem of daily drying and disposal of several dozen tonnes of sludge, which have to be recycled or dumped. In an increasingly stringent environmental context, this

  18. Cogeneration in large processing power stations; Cogeneracion en grandes centrales de proceso

    Energy Technology Data Exchange (ETDEWEB)

    Munoz, Jose Manuel [Observatorio Ciudadano de la Energia A. C., (Mexico)

    2004-06-15

    In this communication it is spoken of the cogeneration in large processing power stations with or without electricity surplus, the characteristics of combined cycle power plants and a comparative analysis in a graph entitled Sale price of electricity in combined cycle and cogeneration power plants. The industrial plants, such as refineries, petrochemical, breweries, paper mills and cellulose plants, among others, with steam necessities for their processes, have the technical and economical conditions to cogenerate, that is, to produce steam and electricity simultaneously. In fact, many of such facilities that exist at the moment in any country, count on cogeneration equipment that allows them to obtain their electricity at a very low cost, taking advantage of the existence steam generators that anyway are indispensable to satisfy their demand. In Mexico, given the existing legal frame, the public services of electricity as well as the oil industry are activities of obligatory character for the State. For these reasons, the subject should be part of the agenda of planning of this power sector. The opportunities to which we are referring to, are valid for the small industries, but from the point of view of the national interest, they are more important for the large size facilities and in that rank, the most numerous are indeed in PEMEX, whereas large energy surplus and capacity would result into cogenerations in refineries and petrochemical facilities and they would be of a high value, precisely for the electricity public service, that is, for the Comision Federal de Electricidad (CFE). [Spanish] En esta ponencia se habla de la cogeneracion en grandes centrales de proceso con o sin excedentes de electricidad, las caracteristicas de plantas de ciclo combinado y se muestra el analisis comparativo en una grafica titulada precio de venta de electricidad en plantas de ciclo combinado y de cogeneracion. Las plantas industriales, tales como refinerias, petroquimicas

  19. Air pollution reduction in thermoelectric power stations - case study: Iquitos power plant; Reducao do impacto da poluicao do ar em usinas termeletricas - estudo de caso: usina termeletrica Iquitos

    Energy Technology Data Exchange (ETDEWEB)

    Dondero, Luz [Sao Paulo Univ., SP (Brazil). Inst. de Energia e Eletrotecnica. Programa Interunidades de Pos-graduacao em Energia]. E-mail: luz@iee.usp.br

    2000-07-01

    This work studies the environmental impacts of atmospheric emissions sent out by the Iquito's thermoelectric power station in Peru. Initially, we compute the quantitative flows (in g/s) of major gas pollutants (SO{sub 2}, SO{sub 3}, NOx, CO, CO{sub 2} and MP) emitted by the power plant. Then, we calculate the station's emission rates per kWh generated (in kilogram of pollutant /kWh). Having those inputs, we adopt EPA's SCREEN3.0 dispersion model to simulate the SO{sub 2} and NOx into the local atmosphere. We also forecast the future evolution of SO{sub 2} emissions considering the potential growth of electricity generation in the power plant. Since the Iquito's power station is located within the city's urban area, with gas emissions having direct impacts upon the local population, we study different strategies for emissions reduction from the plant. Firstly, we consider the upgrading of the existing plant with additional equipment for a more strict emission control. Then, we analyze the option of shutting down the most critical machine (in terms of atmospheric emission) in the old plant, and its substitution by a new and more efficient machine. We concluded that, although the addition of more strict control equipment is more efficient on reducing total emission, the strategy of exchanging machines is less costly and should be consider as the preferable option. (author)

  20. Load converter interactions with the secondary system in the Space Station Freedom power management and distribution dc test bed

    Science.gov (United States)

    Lebron, Ramon C.

    1992-01-01

    The NASA LeRC in Cleveland, Ohio, is responsible for the design, development, and assembly of the Space Station Freedom (SSF) Electrical Power System (EPS). In order to identify and understand system level issues during the SSF program design and development phases, a system Power Management and Distribution (PMAD) dc test bed was assembled. Some of the objectives of this test bed facility are the evaluation of, system efficiency, power quality, system stability, and system protection and reconfiguration schemes. In order to provide a realistic operating scenario, dc Load Converter Units are used in the PMAD dc test bed to characterize the user interface with the power system. These units are dc to dc converters that provide the final system regulation before power is delivered to the load. This final regulation is required on the actual space station because the majority of user loads will require voltage levels different from the secondary bus voltage. This paper describes the testing of load converters in an end to end system environment (from solar array to loads) where their interactions and compatibility with other system components are considered. Some of the system effects of interest that are presented include load converters transient behavior interactions with protective current limiting switchgear, load converters ripple effects, and the effects of load converter constant power behavior with protective features such as foldback.

  1. Load converter interactions with the secondary system in the Space Station Freedom power management and distribution DC test bed

    Science.gov (United States)

    Lebron, Ramon C.

    1992-01-01

    The NASA LeRC in Cleveland, Ohio, is responsible for the design, development, and assembly of the Space Station Freedom (SSF) Electrical Power System (EPS). In order to identify and understand system level issues during the SSF Program design and development phases, a system Power Management and Distribution (PMAD) DC test bed was assembled. Some of the objectives of this test bed facility are the evaluation of, system efficiency, power quality, system stability, and system protection and reconfiguration schemes. In order to provide a realistic operating scenario, dc Load Converter Units are used in the PMAD dc test bed to characterize the user interface with the power system. These units are dc to dc converters that provide the final system regulation before power is delivered to the load. This final regulation is required on the actual space station because the majority of user loads will require voltage levels different from the secondary bus voltage. This paper describes the testing of load converters in an end to end system environment (from solar array to loads) where their interactions and compatibility with other system components are considered. Some of the system effects of interest that are presented include load converters transient behavior interactions with protective current limiting switchgear, load converters ripple effects, and the effects of load converter constant power behavior with protective features such as foldback.

  2. Lawrence Berkeley Laboratory 1994 site environmental report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-05-01

    The 1994 Site Environmental Report summarizes environmental activities at Lawrence Berkeley Laboratory (LBL) for the calendar year (CY) 1994. The report strives to present environmental data in a manner that characterizes the performance and compliance status of the Laboratory`s environmental management programs when measured against regulatory standards and DOE requirements. The report also discusses significant highlight and planning efforts of these programs. The format and content of the report are consistent with the requirements of the U.S. Department of Energy (DOE) Order 5400.1, General Environmental Protection Program.

  3. Effects of thermal discharge on marine ecosystems. A case study from a coastal power station in Southern Italy

    Energy Technology Data Exchange (ETDEWEB)

    Marano, G.; De Zio, V.; Pastorelli, A. M.; Rizzi, E.; Rositani, L.; Ungaro, N. [Laboratorio Provinciale di Biologia Marina, Molo Pizzoli, Bari (Italy)

    2000-07-01

    Environmental impact of thermal effluent from a fuel power station (potential production 660x4 MW) was monitored during 1998, when the production was 50%; the thermal discharge area was located on the south-western Adriatic coast (Mediterranean Sea) and two sampling surveys were carried out (February and November) in order to analyze the composition and distribution of phytoplankton and macrobenthos communities. The biological assemblages seemed to be poorly influenced by heat diffusion. Some differences were observed among macrozoobenthos species distribution, nearby the discharge point, probably due to the influence of strong water flow coming out of the discharge duct; in fact, the strong flowing current could affect the bottom features (sedimentation) of the nearest areas. Because of the monitoring design (sampling scheme, short and seasonal time period), the reported results have a preliminary character; additional information from other surveys (to be carried out during the hot seasons and at maximum power station capacity) is needed.

  4. Small hydro power stations, a way to secure electricity supply in Colombia. A policy evaluation using a system dynamics model

    OpenAIRE

    Perez, Vanessa Margarita

    2013-01-01

    After its deregulation in 1994, the Colombian Electricity Market (CEM) has developed satisfactorily in some sectors, especially in terms of generation and sales to large costumers and to household sector. However, around 70 % of its production capacity is based on hydroelectric power stations that are built using one or more dams. The available water in the dam (considered potential electricity) is from time to time affected by severe weather conditions which might reduce the water inflow by...

  5. Feasibility assessment of a solar-powered charging station for electric vehicles in the North Central region of Bulgaria

    Directory of Open Access Journals (Sweden)

    Ilieva Liliya Mihaylova

    2016-01-01

    Full Text Available The paper discusses the topical issue related to the prospects of widespread deployment of electric vehicles and their associated infrastructure in Bulgaria. The main problems hindering the development of electric vehicle transport are summarized and the current status of charging infrastructure in the country is discussed. An approach is proposed for analysis and evaluation of the financial feasibility of investment in a solar-powered charging station for electric vehicles in North Central region of Bulgaria.

  6. Degradation of Phosphate Ester Hydraulic Fluid in Power Station Turbines Investigated by a Three-Magnet Unilateral Magnet Array

    OpenAIRE

    Pan Guo; Wei He; García-Naranjo, Juan C.

    2014-01-01

    A three-magnet array unilateral NMR sensor with a homogeneous sensitive spot was employed for assessing aging of the turbine oils used in two different power stations. The Carr-Purcell-Meiboom-Gill (CPMG) sequence and Inversion Recovery-prepared CPMG were employed for measuring the 1H-NMR transverse and longitudinal relaxation times of turbine oils with different service status. Two signal components with different lifetimes were obtained by processing the transverse relaxation curves with a ...

  7. Results from installation of waterlance soot blowers at Dairyland Power Cooperative`s JPM station

    Energy Technology Data Exchange (ETDEWEB)

    Hill, D.L. [Dairyland Power Cooperative, La Crosse, WI (United States)

    1995-06-01

    Waterlance soot blowers were installed at the John P. Madgett (JPM) Station in 1992. Improvements in cleaning the furnace and wing wall areas have reduced furnace exit temperature, superheat and reheat sprays, the gas temperature entering the hot side precipitator and NO{sub x} emissions from the Boiler. Overall savings from the waterlances exceeds $11,000,000 in avoided costs and fuel savings. This paper discusses the installation and savings realized from the waterlances at the JPM station.

  8. Three new bricks in the wall: Berkeley 23, Berkeley 31, and King 8

    CERN Document Server

    Cignoni, Michele; Bragaglia, Angela; Tosi, Monica

    2011-01-01

    A comprehensive census of Galactic open cluster properties places unique constraints on the Galactic disc structure and evolution. In this framework we investigate the evolutionary status of three poorly-studied open clusters, Berkeley 31, Berkeley 23 and King 8, all located in the Galactic anti-centre direction. To this aim, we make use of deep LBT observations, reaching more than 6 mag below the main sequence Turn- Off. To determine the cluster parameters, namely age, metallicity, distance, reddening and binary fraction, we compare the observational colour-magnitude diagrams (CMDs) with a library of synthetic CMDs generated with different evolutionary sets (Padova, FRANEC and FST) and metallicities. We find that Berkeley 31 is relatively old, with an age between 2.3 and 2.9 Gyr, and rather high above the Galactic plane, at about 700 pc. Berkeley 23 and King 8 are younger, with best fitting ages in the range 1.1-1.3 Gyr and 0.8-1.3 Gyr, respectively. The position above the Galactic plane is about 500- 600 pc...

  9. Total SO2 Emissions from Power Stations and Evaluation of their Impact in Kuwait Using a Gaussian Plume Dispersion Model

    Directory of Open Access Journals (Sweden)

    A. A. Ramadan

    2008-01-01

    Full Text Available In Kuwait, most of the power stations use fuel oil as the prime source of energy. The sulphur content (S% of the fuel used as well as other factors have a direct impact on the ground level concentration of sulphur dioxide (SO2 released by power stations into the atmosphere. The SO2 ground level concentration has to meet the environmental standards set by Kuwait Environment Public Authority (KEPA. In this communication we present results obtained using the Industrial Sources Complex Short Term (ISCST3 model to calculate the SO2 concentration resulting from existing power stations in Kuwait assuming zero background SO2 concentration and entire reliance on Heavy Fuel Oil. 1, 2, 3 and 4S% scenarios were simulated for three emission cycle cases. The computed annual SO2 concentrations were always less than KEPA standards for all scenarios. The daily SO2 concentrations were within KEPA standards for 1S% but violated KEPA standards for higher S%. In general, the concentrations obtained from the combined hourly and seasonal cycle were the lowest and those obtained from the no cycle case were the highest. The comparison between the results of the three cycles revealed that the violation times cannot be solely attributed to the increase in emissions and the meteorological conditions have to be taken into consideration.

  10. The shallow water equations as a hybrid flow model for the numerical and experimental analysis of hydro power stations

    Energy Technology Data Exchange (ETDEWEB)

    Ostermann, Lars; Seidel, Christian [AG Regenerative Energien, Institut für Statik, TU Braunschweig, Beethovenstrasse 51, 38106 Braunschweig (Germany)

    2015-03-10

    The numerical analysis of hydro power stations is an important method of the hydraulic design and is used for the development and optimisation of hydro power stations in addition to the experiments with the physical submodel of a full model in the hydraulic laboratory. For the numerical analysis, 2D and 3D models are appropriate and commonly used.The 2D models refer mainly to the shallow water equations (SWE), since for this flow model a large experience on a wide field of applications for the flow analysis of numerous problems in hydraulic engineering already exists. Often, the flow model is verified by in situ measurements. In order to consider 3D flow phenomena close to singularities like weirs, hydro power stations etc. the development of a hybrid fluid model is advantageous to improve the quality and significance of the global model. Here, an extended hybrid flow model based on the principle of the SWE is presented. The hybrid flow model directly links the numerical model with the experimental data, which may originate from physical full models, physical submodels and in-situ measurements. Hence a wide field of application of the hybrid model emerges including the improvement of numerical models and the strong coupling of numerical and experimental analysis.

  11. Electric Power Plants and Generation Stations, Power Plants - is a seperate layer, however, we have them included in local building layer as well, Published in 2010, 1:2400 (1in=200ft) scale, Effingham County Government.

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — Electric Power Plants and Generation Stations dataset current as of 2010. Power Plants - is a seperate layer, however, we have them included in local building layer...

  12. The Article Deals with the Improvement of Professional Activity Efficiency of Operational Personnel for Boiler-Turbine Department of Power Stations

    OpenAIRE

    Dmitriev, P.

    2012-01-01

    Human factor is one of the main determining factors in providing stability and reliability of power systems operation. In this context it is significant to estimate the level of professional activity efficiency of operational staff for boiler-turbine department of power stations.The article presents developed by the author algorithm of carrying out such research as well as the results of experimental research, carried out in one of the power stations of the state industrial unity “Belenergo” ...

  13. Atmospheric pollution from power stations: current situation and prospects with regard to legislation. Contaminacion atmosferica de las centrales termicas: situacion actual y perspectivas legislativas

    Energy Technology Data Exchange (ETDEWEB)

    Castiella Villacampa, E.; Asuar Alonso, O.

    1989-11-01

    The monitoring of emissions into the atmosphere from thermal power plants is of vital importance. The recently published Board Directive of 24 November 1988 is therefore one step further towards the protection of the environment. As a consequence, power stations need to make a great effort to adapt. We have also seen that power stations have the technology to quantify their emissions and that they appear to have sufficient time available to reduce them. 5 refs., 3 figs., 1 tab.

  14. Berkeley Lab's ALS generates femtosecond synchrotron radiation

    CERN Document Server

    Robinson, A L

    2000-01-01

    A team at Berkeley's Advanced Light Source has shown how a laser time-slicing technique provides a path to experiments with ultrafast time resolution. A Lawrence Berkeley National Laboratory team has succeeded in generating 300 fs pulses of synchrotron radiation at the ALS synchrotron radiation machine. The team's members come from the Materials Sciences Division (MSD), the Center for Beam Physics in the Accelerator and Fusion Research Division and the Advanced Light Source (ALS). Although this proof-of principle experiment made use of visible light on a borrowed beamline, the laser "time-slicing" technique at the heart of the demonstration will soon be applied in a new bend magnet beamline that was designed specially for the production of femtosecond pulses of X-rays to study long-range and local order in condensed matter with ultrafast time resolution. An undulator beamline based on the same technique has been proposed that will dramatically increase the flux and brightness. The use of X-rays to study the c...

  15. Careers in Data Science: A Berkeley Perspective

    Science.gov (United States)

    Koy, K.

    2015-12-01

    Last year, I took on an amazing opportunity to serve as the Executive Director of the new Berkeley Institute for Data Science (BIDS). After a 15-year career working with geospatial data to advance our understanding of the environment, I have been presented with a unique opportunity through BIDS to work with talented researchers from a wide variety of backgrounds. Founded in 2013, BIDS is a central hub of research and education at UC Berkeley designed to facilitate and nurture data-intensive science. We are building a community centered on a cohort of talented data science fellows and senior fellows who are representative of the world-class researchers from across our campus and are leading the data science revolution within their disciplines. Our initiatives are designed to bring together broad constituents of the data science community, including domain experts from the life, social, and physical sciences and methodological experts from computer science, statistics, and applied mathematics. While many of these individuals rarely cross professional paths, BIDS actively seeks new and creative ways to engage and foster collaboration across these different research fields. In this presentation, I will share my own story, along with some insights into how BIDS is supporting the careers of data scientists, including graduate students, postdocs, faculty, and research staff. I will also describe how these individuals we are helping support are working to address a number of data science-related challenges in scientific research.

  16. Effectiveness of The Development And Expansion of The Steam Power Station Condensate To Centers Thermoelectric Dedicated To The Production of Electric Power And Water Desalination

    Directory of Open Access Journals (Sweden)

    Gamal Yaseen Salman

    2014-04-01

    Full Text Available This research includes a mathematical form to study the effectiveness of development of basic design form condensation steam powers to dual pressure thermoelectric centers allocated for production of electric power and distillation water with the aspect of thermal effectiveness scale and preserving the lowest level of pollution for the surrounding media, in this study the scale of saving is used in the amount of fuel saved in the electric network due to the joint process of production for electric power and distillation water in suggested design compared to a separate production process for electric power and distillation water via a replacement station and distillation unit from the type of reverse osmosis. Hence the effect of design the multiple effect evaporation distillation unit and the gas turbine unit were studied, and so basic thermodynamic characteristics for this unit on the scale of effectiveness for development of basic design of steam st ation. Study findings provided the following:

  17. STUDY THE EFFECT OF ERROSION ON THE BREAKAGE OF STEAM TURBINE BLADE AT BAIJI POWER STATION

    Directory of Open Access Journals (Sweden)

    Mohaned A. Daher

    2013-05-01

    Full Text Available The last stage endured on obvious erosion especially the front and the end of the blade. The erosion caused the appearance some cracks in this place. These remarks coincided with the theoretic   al results, which were acquired according to the condition of the turbine of station which showed that the droplet, which collided with the blade ends, caused high pressure on the surface of the blade and caused the occurrence of the corrosion. The danger of the erosion unavoidable due to its relationship with tae station efficiency and the only to avoid that is the use of the blade made of erosion resistance ingots.

  18. Design of an off-grid hybrid PV/wind power system for remote mobile base station: A case study

    Directory of Open Access Journals (Sweden)

    Mulualem T. Yeshalem

    2017-01-01

    Full Text Available There is a clear challenge to provide reliable cellular mobile service at remote locations where a reliable power supply is not available. So, the existing Mobile towers or Base Transceiver Station (BTSs uses a conventional diesel generator with backup battery banks. This paper presents the solution to utilizing a hybrid of photovoltaic (PV solar and wind power system with a backup battery bank to provide feasibility and reliable electric power for a specific remote mobile base station located at west arise, Oromia. All the necessary modeling, simulation, and techno-economic evaluation are carried out using Hybrid Optimization Model for Electric Renewable (HOMER software. The best optimal system configurations namely PV/Battery and PV/Wind/Battery hybrid systems are compared with the conventional stand-alone diesel generator (DG system. Findings indicated that PV array and battery is the most economically viable option with the total net present cost (NPC of $\\$$57,508 and per unit cost of electricity (COE of $\\$$0.355. Simulation results show that the hybrid energy systems can minimize the power generation cost significantly and can decrease CO2 emissions as compared to the traditional diesel generator only. The sensitivity analysis is also carried out to analysis the effects of probable variation in solar radiation, wind speed, diesel price and average annual energy usage of the system load in the optimal system configurations.

  19. Simultaneous transient operation of a high head hydro power plant and a storage pumping station in the same hydraulic scheme

    Science.gov (United States)

    Bucur, D. M.; Dunca, G.; Cervantes, M. J.; Cǎlinoiu, C.; Isbǎşoiu, E. C.

    2014-03-01

    This paper presents an on-site experimental analysis of a high head hydro power plant and a storage pumping station, in an interconnected complex hydraulic scheme during simultaneous transient operation. The investigated hydropower site has a unique structure as the pumping station discharges the water into the hydropower plant penstock. The operation regimes were chosen for critical scenarios such as sudden load rejections of the turbines as well as start-ups and stops with different combinations of the hydraulic turbines and pumps operation. Several parameters were simultaneously measured such as the pumped water discharge, the pressure at the inlet pump section, at the outlet of the pumps and at the vane house of the hydraulic power plant surge tank. The results showed the dependence of the turbines and the pumps operation. Simultaneous operation of the turbines and the pumps is possible in safe conditions, without endangering the machines or the structures. Furthermore, simultaneous operation of the pumping station together with the hydropower plant increases the overall hydraulic efficiency of the site since shortening the discharge circuit of the pumps.

  20. Impact Assessment of Changing Fuel on Water Consumption in Kuwait’s Power Station

    Directory of Open Access Journals (Sweden)

    Fahad Alhajri

    2017-04-01

    Full Text Available Demands on electricity are in continuous increase and as a result an increase on water consumption and withdrawal. A huge expansion is done by Kuwait seven stations to meet the need of water and electricity using different combinations of four types of fuel (natural gas, gas oil, heavy fuel oil and crude oil. This study aims to determine the optimum fuel for reducing water consumption and cost without changing the capacity of electricity production in Kuwait. To attain that water consumption and/or withdrawal factor had been calculated for each fuel in each station depending on electricity and water consumption and production values, then cost of each mega watt produced had been determined using calculated cost of each fuel. It is concluded that natural gas is the least consuming water and least productivity for electricity where heavy fuel oil is the cheapest one and gas oil is the most expensive and most consuming water. However more time and detailed analysis are needed to determine the optimum fuel. Three scenarios had been assumed on different stations, best one was in Az-zour station when we decreased natural gas percentage and it was compensated by crude oil with keeping gas oil as it was. Consequently, it was noticed there was increase in water consumption and decrease in the cost: about 2 million Kuwait dinars.

  1. The Berkeley gas-filled separator

    CERN Document Server

    Ninov, V; McGrath, C A

    1998-01-01

    The BGS is being constructed at the 88-Inch Cyclotron at LBNL in Berkeley. The magnetic configuration of the BGS will allow a large angular acceptance and good suppression of primary beam particles. BGS operates as a mass spectrometer with a A/ Delta A approximately =200 and as a gas filled separator at pressures between 0.1-50 hPa. The reaction products recoiling off a thin target will be collected with efficiencies from 10-80at the focal plane. A Monte Carlo simulation program of the ion transport through the gas-filled magnets in combination of 3-dimensional TOSCA field maps has been developed and reproduces closely the experimental behavior of BGS. (9 refs).

  2. The Berkeley extreme ultraviolet calibration facility

    Science.gov (United States)

    Welsh, Barry Y.; Jelinsky, Patrick; Malina, Roger F.

    1988-01-01

    The vacuum calibration facilities of the Space Sciences Laboratory, University of California at Berkeley are designed for the calibration and testing of EUV and FUV spaceborne instrumentation (spectral range 44-2500 A). The facility includes one large cylindrical vacuum chamber (3 x 5 m) containing two EUV collimators, and it is equipped with a 4-axis manipulator of angular-control resolution 1 arcsec for payloads weighing up to 500 kg. In addition, two smaller cylindrical chambers, each 0.9 x 1.2 m, are available for vacuum and thermal testing of UV detectors, filters, and space electronics hardware. All three chambers open into class-10,000 clean rooms, and all calibrations are referred to NBS secondary standards.

  3. Telescience at the University of California, Berkeley

    Science.gov (United States)

    Chakrabarti, S.; Marchant, W. T.; Kaplan, G. C.; Dobson, C. A.; Jernigan, J. G.; Lampton, M. L.; Malina, R. F.

    1989-01-01

    The University of California at Berkeley (UCB) is a member of a university consortium involved in telescience testbed activities under the sponsorship of NASA. Our Telescience Testbed Project consists of three experiments using flight hardware being developed for the Extreme Ultraviolet Explorer project at UCB's Space Sciences Laboratory. The first one is a teleoperation experiment investigating remote instrument control using a computer network such as the Internet. The second experiment is an effort to develop a system for operation of a network of remote workstations allowing coordinated software development, evaluation, and use by widely dispersed groups. The final experiment concerns simulation as a method to facilitate the concurrent development of instrument hardware and support software. We describe our progress in these areas.

  4. Lawrence Berkeley Laboratory Affirmative Action Program. Revised

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-06-01

    The Lawrence Berkeley Laboratory`s Affirmative Action Program (AAP) serves as a working document that describes current policies, practices, and results in the area of affirmative action. It represents the Laboratory`s framework for an affirmative approach to increasing the representation of people of color and women in segments of our work force where they have been underrepresented and taking action to increase the employment of persons with disabilities and special disabled and Vietnam era veterans. The AAP describes the hierarchy of responsibility for Laboratory affirmative action, the mechanisms that exist for full Laboratory participation in the AAP, the policies and procedures governing recruitment at all levels, the Laboratory`s plan for monitoring, reporting, and evaluating affirmative action progress, and a description of special affirmative action programs and plans the Laboratory has used and will use in its efforts to increase the representation and retention of groups historically underrepresented in our work force.

  5. COMBINED CYCLE GAS TURBINE FOR THERMAL POWER STATIONS: EXPERIENCE IN DESIGNING AND OPERATION, PROSPECTS IN APPLICATION

    Directory of Open Access Journals (Sweden)

    N. V. Karnitsky

    2014-01-01

    Full Text Available The paper has reviewed main world tendencies in power consumption and power system structure. Main schemes of combined cycle gas turbines have been considered in the paper. The paper contains an operational analysis of CCGT blocks that are operating within the Belarusian energy system. The analysis results have been given in tables showing main operational indices of power blocks

  6. Integrated Gasification Combined Cycle (IGCC) demonstration project, Polk Power Station -- Unit No. 1. Annual report, October 1993--September 1994

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-05-01

    This describes the Tampa Electric Company`s Polk Power Station Unit 1 (PPS-1) Integrated Gasification Combined Cycle (IGCC) demonstration project which will use a Texaco pressurized, oxygen-blown, entrained-flow coal gasifier to convert approximately 2,300 tons per day of coal (dry basis) coupled with a combined cycle power block to produce a net 250 MW electrical power output. Coal is slurried in water, combined with 95% pure oxygen from an air separation unit, and sent to the gasifier to produce a high temperature, high pressure, medium-Btu syngas with a heat content of about 250 Btu/scf (LHV). The syngas then flows through a high temperature heat recovery unit which cools the syngas prior to its entering the cleanup systems. Molten coal ash flows from the bottom of the high temperature heat recovery unit into a water-filled quench chamber where it solidifies into a marketable slag by-product.

  7. Junior High Schools of Berkeley, California. Bulletin, 1923, No. 4

    Science.gov (United States)

    Preston, James T.; Clark, W. B.; Glessner, H. H.; Hennessey, D. L.

    1923-01-01

    This bulletin demonstrates that Berkeley, California's educational problem is and has been that of meeting the varied needs of a population such as may be found in any typical American city. The varied population needs, together with the rapid growth, have brought many difficult problems to Berkeley, just has they have to other cities. Based on…

  8. Dispersion of As and selected heavy metals around a coal-burning power station in central Slovakia

    Energy Technology Data Exchange (ETDEWEB)

    Keegan, T.J.; Farago, M.E.; Thornton, I.; Hong, Bing; Colvile, R.N.; Nieuwenhuijsen, M.J. [Imperial College of Science, Technology and Medicine, London (United Kingdom); Pesch, B. [Institut fur Umweltmedizinische Forschung and der Heinrich-Heine-Universitat, Dusseldorf, Dusseldorf (Germany); Jakubis, P. [State Health Institute, Prievidza (Slovakia)

    2006-04-01

    A power station in central Slovakia emitted arsenic (As) in large quantities for over 30 years as a result of burning As-rich brown coal. Nowadays emissions of As are low. Over the lifetime of the plant's operation over 3000 tonne of As have been emitted into the environment. This paper aims to examine the concentrations of As in the soil around the power station, and also to investigate whether the coal burnt in the plant, and consequently the emissions from it, contained raised levels of six further heavy metals. Soil concentrations were compared to ground level air As concentrations predicted by an air dispersion model. Coal samples were taken from the power station and analysed to determine concentrations of As, Zn, Pb, Cu, Cr, Ni and Cd. Soil samples (n=113) were taken up to 12 km from the plant along a transect designed to follow the valley floor in which the power station is situated. Soil samples were analysed for concentrations of those elements for which coal was tested. Concentrations of As in coal were high (AM 518 {mu}g/g). Those of other heavy metals were, in general, low. Concentrations of soil As were substantially raised in the near vicinity of the plant but decreased within 5 km to concentrations similar to those in the rest of the district. Overall, levels within 10 km of the plant were slightly above those recommended for residential levels in the UK. Soil concentrations of other heavy metals were higher in the vicinity of the plant but none, overall was raised. Comparison of results from a previous air dispersion model of ground level air arsenic concentrations showed a moderate correlation (r=0.6) between modelled and measured values. Over its period of operation the power plant has contributed to raised levels of soil As in the local soils, though not substantially of other elements. Though now airborne As emissions are controlled, concern remains regarding soil arsenic concentrations and fugitive emissions from the plant that could be

  9. Evaluation of environmental data relating to selected nuclear power plant sites. The Zion Nuclear Power Station site

    Energy Technology Data Exchange (ETDEWEB)

    Murarka, I.P.; Policastro, A.; Daniels, E.; Ferrante, J.; Vaslow, F.

    1976-11-01

    Environmental monitoring data for the years 1972 through 1975 pertaining to the Zion Station, which began commercial operation in 1974, were analyzed by the most practical qualitative and quantitative methods. Thermal plume, water chemistry and aquatic biota data were evaluated and the results are presented. The results showed no significant immediate deleterious effects, thus confirming preoperational predictions. Although the plant has not operated long enough to reveal long-term deleterious effects, the present indications do not lead to a concerned prediction that any are developing. The data utilized, the methods of analysis, and the results obtained are presented in detail, along with recommendations for improving monitoring techniques.

  10. Process engineering and design aspects for oxyfuel retrofits of existing state-of-the-art power stations - bringing 'capture ready' to reality

    Energy Technology Data Exchange (ETDEWEB)

    Tigges, K.-D.; Klauke, F.; Bergins, C.; Busekrus, K.; Niesbach, J.; Ehmann, M. (and others) [Hitachi Power Europe GmbH (Germany)

    2008-07-01

    The plant modifications and new components required for retrofitting oxyfuel firing to an existing power station is described, along with changes in firing and flue gas cleaning processes. 6 refs., 10 figs., 3 tabs.

  11. 拟定蒙西电网风电与蓄能电站配合运行规模的简化方法%A Simplified Determination Method for Capacity Combination of Wind Power Stations and Pumped Storage Power Stations in West Inner Mongolia Power Grid

    Institute of Scientific and Technical Information of China (English)

    曾非同; 陈初龙; 唐修波

    2015-01-01

    大规模风电接入对电网影响较大,而抽水蓄能电站启停迅速,可以较好的配合风电运行,减小对电网的影响. 结合内蒙古西部电网(简称蒙西电网)风电基地出力特性和典型日负荷特性,从风电与用电负荷的吻合程度、对电网调峰容量的影响、弃风电量的经济比较分析,抓住了影响风电与抽水蓄能电站配合运行规模的主要因素:在负荷低谷时段风电的上网(容量)率,提出了合理的简化方法. 该方法简单直观、实用有效,需要的资料少,对合理开发利用风电资源的规模估算具有实际指导意义,对风电与抽水蓄能电站配合运行规模的规划设计具有参考价值.%Large-scale use of wind power raises many problems in integration into the existing power grid .While the pumped storage power stations are of advantages such as quick startup and shutdown , which could cooperate with wind power stations and reduce their negative influence to the power grid .In this paper , capacity planning for the wind power base in the West Inner Mongolia Power Grid is discussed .Based on the characteristics of output power and typical daily load, major factors that would affect the capacity combination of wind power stations and pumped storage power stations in the power grid are analyzed , including the agreement between the wind power output and the power load , the influ-ence on the peak regulating capacity , and the cost of abandoned wind power .A simplified method is then proposed for the determination of wind power capacity rate in the low load period .This effective and practical method is of great use to the wind power capacity planning , and also could be a useful reference for the capacity planning of power grid with combination of wind power stations and pumped storage power stations .

  12. 建设蓄能电站解决风电消纳经济性分析%Economic Analysis on Constructing Storage Stations for Consuming Wind Power

    Institute of Scientific and Technical Information of China (English)

    靳亚东; 董化宏; 马登清

    2011-01-01

    用电市场对风电消纳能力不足已经成为制约风电发展的“瓶颈”,建设抽水蓄能电站被认为是水电缺乏地区调整电源结构、解决风电消纳能力问题的有效途径,但建设抽水蓄能电站解决风电消纳的经济性问题一直是个疑问,通过详细的方案测算认为在一定的条件下,电网企业或发电公司建设抽水蓄能电站解决风电消纳是经济可行的.%The capacity shortage of electricity market for consuming wind power has been regarded as the "bottleneck" of wind power development, and the construction of pumped-storage power stations has been also considered to be an effective way to adjust power source structure and solve wind power consumption for the areas without sufficient hydropower sources, but the economy of constructing pumped -storage power stations has been a question. The economy is analyzed for constructing pumped-storage power stations to consume wind power, and the case study shows that, in certain conditions, constructing pumped-storage power stations to consume wind power by power grid and generation enterprises is feasible in economy.

  13. What Made Berkeley Great? The Sources of Berkeley's Sustained Academic Excellence. Research & Occasional Paper Series CSHE.3.11

    Science.gov (United States)

    Breslauer, George W.

    2011-01-01

    University of California (UC) Berkeley's chief academic officer explores the historical sources of Berkeley' academic excellence. He identifies five key factors: (1) wealth from many sources; (2) supportive and skilled governors; (3) leadership from key UC presidents; (4) the pioneering ethos within the State of California; and (5) a process of…

  14. Cooperating expert systems for Space Station - Power/thermal subsystem testbeds

    Science.gov (United States)

    Wong, Carla M.; Weeks, David J.; Sundberg, Gale R.; Healey, Kathleen L.; Dominick, Jeffrey S.

    1988-01-01

    The Systems Autonomy Demonstration Project (SADP) is a NASA-sponsored series of increasingly complex demonstrations to show the benefits of integrating knowledge-based systems with conventional process control in real-time, real-world problem domains that can facilitate the operations and availability of major Space Station distributed systems. This paper describes the system design, objectives, approaches, and status of each of the testbed knowledge-based systems. Simplified schematics of the systems are shown.

  15. Universal turbine for drinking-water power stations; Universell einsetzbare Turbine fuer Wasserversorgungen. Nutzung von Druckreduzierenergie im Gegendruckbereich - Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Schindelholz, B.; Fritschi, M.

    2009-03-15

    This final report for the Swiss Federal Office of Energy (SFOE) takes a look at a universal turbine for use in drinking-water power stations. The aims of the project are discussed and the importance of the turbine's axle seal is stressed. The use of this Pelton turbine operating in a cushion of compressed air is discussed. Counter-pressure control is discussed, as is the air inflow which is needed to replace the air carried out by the water. Industry-partners involved in the project are noted. The importance of using such small-hydro schemes to help meet energy needs is discussed.

  16. Change in plant cycle chemistry from hydrazine/phosphate to amine/polyamine treatment in an industrial power station

    Energy Technology Data Exchange (ETDEWEB)

    Vogt, T.; Besl, G. [TUeV SUeD Industrie Service GmbH, Muenchen (Germany); Stecklina, M. [MD Papier GmbH, Dachau (Germany)

    2007-08-15

    In an industrial power station with several natural circulation boilers (permissible operation pressure 13.6 MPa), raw water treatment via demineralization, condensate polishing and thermal feedwater degasification, the cycle chemistry was changed from hydrazine/phosphate to amine/polyamine treatment. The modification was supervised by TUeV SUeD with several water chemical analyses of the water/steam circuit. No problematic water conditions were found during the investigations. Fewer condensate impurities and a reduced amount of boiler blowdown can be stated as positive results of the transition to the polyamine treatment. (orig.)

  17. The features of ceramic materials structure formation when using hard-melting wastes of thermal power stations in charge stock

    Science.gov (United States)

    Skripnikova, Nelli; Yuriev, Ivan; Lutsenko, Alexander; Litvinova, Viktoriya

    2016-01-01

    The paper presents the analysis of aluminum silicate waste generated by thermal power station of the city of Seversk, Tomsk region, Russia. The chemical compositions of aluminum silicate waste are detected and the efficient mixture compositions with the addition of aluminum silicate waste are suggested herein. Ceramic brick structure formation is studied in this paper using X-ray phase and SEM analyses. It is identified that the formed vitreous phase facilitates such strengthening structural modifications as sintering out of pores and shrinkage of unmelted aluminum silicate particles with the following formation of a monolithic product.

  18. Self-Oscillating Soft Switching Envelope Tracking Power Supply for Tetra2 Base Station

    DEFF Research Database (Denmark)

    Høyerby, Mikkel Christian Wendelboe; Andersen, Michael Andreas E.

    2007-01-01

    ) implemented with a series inductor and an external clamping power supply. Combined with advanced power stage components (die-size MOSFETs), a high-performance fixed-frequency self-oscillating (sliding mode) control strategy and a 4th-order output filter, this leads to a compact, effective and efficient...

  19. Predictability of PV power grid performance on insular sites without weather stations: use of artificial neural networks

    CERN Document Server

    Voyant, Cyril; Paoli, Christophe; Nivet, Marie Laure; Poggi, Philippe; Haurant, P; 10.4229/24thEUPVSEC2009-5BV.2.35

    2010-01-01

    The official meteorological network is poor on the island of Corsica: only three sites being about 50 km apart are equipped with pyranometers which enable measurements by hourly and daily step. These sites are Ajaccio (41\\degree 55'N and 8\\degree 48'E, seaside), Bastia (42\\degree 33'N, 9\\degree 29'E, seaside) and Corte (42\\degree 30'N, 9\\degree 15'E average altitude of 486 meters). This lack of weather station makes difficult the predictability of PV power grid performance. This work intends to study a methodology which can predict global solar irradiation using data available from another location for daily and hourly horizon. In order to achieve this prediction, we have used Artificial Neural Network which is a popular artificial intelligence technique in the forecasting domain. A simulator has been obtained using data available for the station of Ajaccio that is the only station for which we have a lot of data: 16 years from 1972 to 1987. Then we have tested the efficiency of this simulator in two places w...

  20. Electric Power Plants and Generation Stations - POWER_HAZUS_IN: Electric Power Facilities in Indiana, Derived from HAZUS (Federal Emergency Management Agency, Point Shapefile)

    Data.gov (United States)

    NSGIC GIS Inventory (aka Ramona) — POWER_HAZUS_IN is a point shapefile that shows locations of electric power facilities in Indiana. POWER_HAZUS_IN was derived from the shapefile named "ELECTRIC." A...

  1. Measurement of the magnetic properties of P9 and T22 steel taken from service in power station

    Science.gov (United States)

    Wilson, J. W.; Karimian, N.; Liu, J.; Yin, W.; Davis, C. L.; Peyton, A. J.

    2014-06-01

    With the UK's aging power generation network, life-extension of steel plant components is a critical issue. However, in order to evaluate the likelihood of component failure, techniques must be developed to properly assess the level of degradation in power station steels. Electromagnetic inspection has the potential to quantify the level of degradation through in-situ measurements at elevated temperatures. This paper reports the results of tests carried out on thermally treated P9 and T22 steel samples with different microstructural states using major and minor B-H loop measurements and magnetic Barkhausen noise measurements. The results show that by careful selection of minor loop parameters, specific to the material under inspection and the material change under consideration, correlations can established between EM properties and material properties such as Vickers hardness. These results will be used as a basis for the further development of a fully field deployable device.

  2. Management and construction of a major zero discharge water supply and treatment scheme at Mount Piper Power Station, Australia

    Energy Technology Data Exchange (ETDEWEB)

    Wong, P.; Docker, P.; Gabbrielli, E.; Wade, P. [Pacific Power, Sydney, NSW (Australia)

    1994-09-01

    Excellence in the organisation and management of a large multi-disciplinary design and construct project such as the zero discharge water supply and treatment scheme for Mount Piper coal-fired power station was essential to its successful execution. This paper discusses the management philosophies and strategies of Pacific Power and Transfield-PWT Asia/Pacific that resulted in this project being completed to the satisfaction of the client in the minimum time without delays and cost increases caused by interfaces between the parties. It highlights the advantages of contract packaging and placing the total responsibility for the performance and integration of a complex project system on one organisation. 2 refs., 6 figs.

  3. 75 FR 80546 - Virginia Electric and Power Company; Surry Power Station Unit Nos. 1 and 2; Exemption

    Science.gov (United States)

    2010-12-22

    ... systems for light-water nuclear power reactors,'' and Appendix K to 10 CFR Part 50, ``ECCS Evaluation... or ZIRLO TM fuel rod cladding. Thus, an exemption from the requirements of 10 CFR 50.46 and Appendix K is needed to support the use of different fuel rod cladding material. Therefore, the...

  4. MODEL PREDICTIVE CONTROL FOR PHOTOVOLTAIC STATION MAXIMUM POWER POINT TRACKING SYSTEM

    Directory of Open Access Journals (Sweden)

    I. Elzein

    2015-01-01

    Full Text Available The purpose of this paper is to present an alternative maximum power point tracking, MPPT, algorithm for a photovoltaic module, PVM, to produce the maximum power, Pmax, using the optimal duty ratio, D, for different types of converters and load matching.We present a state-based approach to the design of the maximum power point tracker for a stand-alone photovoltaic power generation system. The system under consideration consists of a solar array with nonlinear time-varying characteristics, a step-up converter with appropriate filter.The proposed algorithm has the advantages of maximizing the efficiency of the power utilization, can be integrated to other MPPT algorithms without affecting the PVM performance, is excellent for Real-Time applications and is a robust analytical method, different from the traditional MPPT algorithms which are more based on trial and error, or comparisons between present and past states. The procedure to calculate the optimal duty ratio for a buck, boost and buck-boost converters, to transfer the maximum power from a PVM to a load, is presented in the paper. Additionally, the existence and uniqueness of optimal internal impedance, to transfer the maximum power from a photovoltaic module using load matching, is proved.

  5. Cluster Control of Offshore Wind Power Plants Connected to a Common HVDC Station

    DEFF Research Database (Denmark)

    Göksu, Ömer; Sakamuri, Jayachandra N.; Rapp, C. Andrea;

    2016-01-01

    In this paper a coordinated control for cluster of offshore WPPs connected to the same HVDC connection is being implemented and analyzed. The study is targeting two cases as; coordination of reactive power flow between HVDC converter and the WPP cluster while providing offshore AC grid voltage...... control, and coordinated closed loop control between the HVDC and the WPPs while the cluster is providing Power Oscillation Damping ( POD) via active power modulation. It is shown that the coordinated cluster control helps to improve the steady-state and dynamic response of the offshore AC grid in case...

  6. Capacity control of power stations by O 2/H 2 rocket combustor technology

    Science.gov (United States)

    Sternfeld, Ing. H. J.

    1995-10-01

    The concept of a hydrogen/oxygen spinning reserve system is described. The novel component of this concept is a socalled hydrogen/oxygen steam generator derived from modern H 2/O 2 rocket combustor technology. With the HYDROSS-project the DLR and German power plant industries as well as electric utilities have converted the rocket combustor technology to a power plant component. The status of the project as well as technical problems encountered with the conversion are described. Finally, future options for utilizing H 2/O 2 steam generator technology for stand-by and peak-load power plants are discussed.

  7. Degradation of Phosphate Ester Hydraulic Fluid in Power Station Turbines Investigated by a Three-Magnet Unilateral Magnet Array

    Directory of Open Access Journals (Sweden)

    Pan Guo

    2014-04-01

    Full Text Available A three-magnet array unilateral NMR sensor with a homogeneous sensitive spot was employed for assessing aging of the turbine oils used in two different power stations. The Carr-Purcell-Meiboom-Gill (CPMG sequence and Inversion Recovery-prepared CPMG were employed for measuring the 1H-NMR transverse and longitudinal relaxation times of turbine oils with different service status. Two signal components with different lifetimes were obtained by processing the transverse relaxation curves with a numeric program based on the Inverse Laplace Transformation. The long lifetime components of the transverse relaxation time T2eff and longitudinal relaxation time T1 were chosen to monitor the hydraulic fluid aging. The results demonstrate that an increase of the service time of the turbine oils clearly results in a decrease of T2eff,long and T1,long. This indicates that the T2eff,long and T1,long relaxation times, obtained from the unilateral magnetic resonance measurements, can be applied as indices for degradation of the hydraulic fluid in power station turbines.

  8. Estimating the effect of air pollution from a coal-fired power station on the development of children's pulmonary function.

    Science.gov (United States)

    Dubnov, Jonathan; Barchana, Micha; Rishpon, Shmuel; Leventhal, Alex; Segal, Isaac; Carel, Rafael; Portnov, Boris A

    2007-01-01

    Using geographical information systems (GIS) tools, the present study analyzed the association between children's lung function development and their long-term exposure to air pollution. The study covered the cohort of 1492 schoolchildren living in the vicinity of a major coal-fired power station in the Hadera sub-district of Israel. In 1996 and 1999, the children underwent subsequent pulmonary function tests (PFT) (forced vital capacity (FVC) and forced expiratory volume during the first second (FEV(1))), and the children's parents completed a detailed questionnaire on their health status and household characteristics. A negative association was found between changes in the results of PFT and the estimated individual levels of air pollution. A sensitivity test revealed a FEV(1) decline from -4.3% for the average pollution level to -10.2% for the high air pollution level. The results of a sensitivity test for FVC were found to be similar. Association with the reported health status was found to be insignificant. As we conclude, air pollution from a coal-fired power station, although not exceeding local pollution standards, had a negative effect on children's lung function development. As argued, previous studies carried out in the region failed to show the above association because they were based on zone approaches that assign average concentration levels of air pollutants to all individuals in each zone, leading to a misclassification bias of individual exposure.

  9. DS-CDMA Cellular Systems Performance with Base Station Assignment, Power Control Error and Beamforming over Multipath Fading

    Directory of Open Access Journals (Sweden)

    Mohamad Dosaranian Moghadam

    2011-01-01

    Full Text Available The interference reduction capability of antenna arrays, base station assignment and the power controlalgorithms have been considered separately as means to increase the capacity in wireless communicationnetworks. In this paper, we propose base station assignment method based on minimizing the transmitterpower (BSA-MTP technique in a direct sequence-code division multiple access (DS-CDMA receiver inthe presence of frequency-selective Rayleigh fading and power control error (PCE. This receiverconsists of constrained least mean squared (CLMS algorithm, matched filter (MF, and maximal ratiocombining (MRC in three stages. Also, we present switched-beam (SB technique in the first stage of theRAKE receiver for enhancing signal to interference plus noise ratio (SINR in DS-CDMA cellularsystems. The simulation results indicate that BSA-MTP technique can significantly improve the networkbit error rate (BER in comparison with the conventional case. Finally, we discuss on three parameters ofthe PCE, number of resolvable paths, and channel propagation conditions (path-loss exponent andshadowing and their effects on capacity of the system via some computer simulations.

  10. Transmit Power Minimization and Base Station Planning for High-Speed Trains with Multiple Moving Relays in OFDMA Systems

    KAUST Repository

    Ghazzai, Hakim

    2016-03-15

    High-speed railway system equipped with moving relay stations placed on the middle of the ceiling of each train wagon is investigated. The users inside the train are served in two hops via the orthogonal frequency-division multiple access (OFDMA) technology. In this work, we first focus on minimizing the total downlink power consumption of the base station (BS) and the moving relays while respecting specific quality of service (QoS) constraints. We first derive the optimal resource allocation solution in terms of OFDMA subcarriers and power allocation using the dual decomposition method. Then, we propose an efficient algorithm based on the Hungarian method in order to find a suboptimal but low complexity solution. Moreover, we propose an OFDMA planning solution for high-speed train by finding the maximal inter-BS distance given the required user data rates in order to perform seamless handover. Our simulation results illustrate the performance of the proposed resource allocation schemes in the case of the 3GPP Long Term Evolution-Advanced (LTE-A) and compare them with previously developed algorithms as well as with the direct transmission scenario. Our results also highlight the significant planning gain obtained thanks to the use of multiple relays instead of the conventional single relay scenario.

  11. Selection of site coolant intake and discharge of shore based power stations - coastal oceanographic considerations

    Digital Repository Service at National Institute of Oceanography (India)

    Swamy, G.N.; Suryanarayana, A.; Krishnakumar, V.

    Many new nuclear power plants, reactors are proposed along coastal area of Indian coastline apart from the existing ones. All these, being ultimately a heat exchange process, necessitate enormous quantity of cooling water drawn from the sea...

  12. Design Analysis of SNS Target StationBiological Shielding Monoligh with Proton Power Uprate

    Energy Technology Data Exchange (ETDEWEB)

    Bekar, Kursat B. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Ibrahim, Ahmad M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-05-01

    This report documents the analysis of the dose rate in the experiment area outside the Spallation Neutron Source (SNS) target station shielding monolith with proton beam energy of 1.3 GeV. The analysis implemented a coupled three dimensional (3D)/two dimensional (2D) approach that used both the Monte Carlo N-Particle Extended (MCNPX) 3D Monte Carlo code and the Discrete Ordinates Transport (DORT) two dimensional deterministic code. The analysis with proton beam energy of 1.3 GeV showed that the dose rate in continuously occupied areas on the lateral surface outside the SNS target station shielding monolith is less than 0.25 mrem/h, which complies with the SNS facility design objective. However, the methods and codes used in this analysis are out of date and unsupported, and the 2D approximation of the target shielding monolith does not accurately represent the geometry. We recommend that this analysis is updated with modern codes and libraries such as ADVANTG or SHIFT. These codes have demonstrated very high efficiency in performing full 3D radiation shielding analyses of similar and even more difficult problems.

  13. Evaluation of the prompt alerting systems at four nuclear power stations

    Energy Technology Data Exchange (ETDEWEB)

    Towers, D.A.; Anderson, G.S.; Keast, D.N.; Kenoyer, J.L.; Desrosiers, A.E.

    1982-09-01

    This report presents evaluations of the prompt notification siren systems at the following four US nuclear power facilities: Trojan, Three Mile Island, Indian Point, and Zion. The objective of these evaluations was to provide examples of an analytical procedure for predicting siren-system effectiveness under specific conditions in the 10-mile emergency planning zone (EPZ) surrounding nuclear power plants. This analytical procedure is discussed in report No. PNL-4227.

  14. Construction and environmental aspects of hydroelectric power stations; Bauliche Gestaltung und Umweltaspekte von Wasserkraftanlagen

    Energy Technology Data Exchange (ETDEWEB)

    Giesecke, J. [Stuttgart Univ. (Germany). Inst. fuer Wasserbau

    1997-12-31

    In terms of environmental-friendliness, inexhaustibility, availability, non-pollution and cost conditions, hydro power is the most obvious renewable energy source. Harnessing of hydro power does interfere with nature. But there are ways of reconciling economic and ecological concerns. (orig.) [Deutsch] Im Hinblick auf Umweltfreundlichkeit, Unerschoepflichkeit, Verfuegbarkeit, Schadstofffreiheit und Kostenlage stellt die Wasserkraft die vorrangige erneuerbare Energiequelle dar. Ihre Nutzung fuehrt zu Eingriffen in die Natur. Es gibt jedoch Wege, die Belange der Oekonomie und der Oekologie ausgewogen aufeinander abzustimmen. (orig.)

  15. Efficiency Enhancement of Pico-cell Base Station Power Amplifier MMIC in Gallium Nitride HFET Technology Using the Doherty technique

    Science.gov (United States)

    Seneviratne, Sashieka

    With the growth of smart phones, the demand for more broadband, data centric technologies are being driven higher. As mobile operators worldwide plan and deploy 4th generation (4G) networks such as LTE to support the relentless growth in mobile data demand, the need for strategically positioned pico-sized cellular base stations known as 'pico-cells' are gaining traction. In addition to having to design a transceiver in a much compact footprint, pico-cells must still face the technical challenges presented by the new 4G systems, such as reduced power consumptions and linear amplification of the signals. The RF power amplifier (PA) that amplifies the output signals of 4G pico-cell systems face challenges to minimize size, achieve high average efficiencies and broader bandwidths while maintaining linearity and operating at higher frequencies. 4G standards as LTE use non-constant envelope modulation techniques with high peak to average ratios. Power amplifiers implemented in such applications are forced to operate at a backed off region from saturation. Therefore, in order to reduce power consumption, a design of a high efficiency PA that can maintain the efficiency for a wider range of radio frequency signals is required. The primary focus of this thesis is to enhance the efficiency of a compact RF amplifier suitable for a 4G pico-cell base station. For this aim, an integrated two way Doherty amplifier design in a compact 10mm x 11.5mm2 monolithic microwave integrated circuit using GaN device technology is presented. Using non-linear GaN HFETs models, the design achieves high effi-ciencies of over 50% at both back-off and peak power regions without compromising on the stringent linearity requirements of 4G LTE standards. This demonstrates a 17% increase in power added efficiency at 6 dB back off from peak power compared to conventional Class AB amplifier performance. Performance optimization techniques to select between high efficiency and high linearity operation are

  16. Radioactive ion beam development in Berkeley

    CERN Document Server

    Wutte, D C; Leitner, M A; Xie, Z Q

    1999-01-01

    Two radioactive ion beam projects are under development at the 88" Cyclotron, BEARS (Berkeley Experiment with accelerated radioactive species) and the 14O experiment. The projects are initially focused on the production of 11C and 14O, but it is planned to expand the program to 17F, 18F, 13N and 76Kr. For the BEARS project, the radioactivity is produced in form of either CO2 or N2O in a small medical 10 MeV proton cyclotron. The activity is then transported through a 300 m long He-jet line to the 88" cyclotron building, injected into the AECR-U ion source and accelerated through the 88" cyclotron to energies between 1 to 30 MeV/ nucleon. The 14O experiment is a new experiment at the 88" cyclotron to measure the energy-shape of the beta decay spectrum. For this purpose, a target transfer line and a radioactive ion beam test stand has been constructed. The radioactivity is produced in form of CO in a hot carbon target with a 20 MeV 3He from the 88" Cyclotron. The activity diffuses through an 8m long stainless s...

  17. Laser orbital energy moduleâ'the first step to space power station

    Science.gov (United States)

    Babaev, Igor K.; Leontiev, Alexandr I.; Samsonov, Vladimir L.; Schmidt, Konstantin L.; Katorgin, Boris I.; Ponomarov-Stepney, Niokolay N.

    1995-01-01

    The possibility of power module development as the first step for the development of an orbital power state (OPS) is reviewed in this report. The most probable OPS scheme is a laser system with direct nuclear pumping. Since this task is not yet been defined well enough in its technical form, a better developed prototype has been selected in the form of a free electron laser with the power system on the basis of a gas core nuclear reactor (MGD)—generator and multi-modular closed gas turbine system. Taking into consideration that many of the elements of this orbital complex are in the stage of advanced development within current programs in different countries, we propose to continue the research and development of the remainder of the key elements. This work was carried out earlier for military purposes but was halted after the end of the cold war. It is proposed to perform this work within the framework of international cooperation, and a lot of the achievements of the Russian nuclear and aerospace technology will be utilized in the project. It will be a worthwhile task to achieve within 6-8 years the development of an orbital power module with a shortwave laser having the power of NL=100 kW for short-time periodical energy transmision from the 500 km orbital to a stationary site in Eastern Siberia. The power supply for this laser is based upon a closed high temperature gas turbine system with a graphite heat accumulator, which is charged with electricity generated by the ``Topaz''-type nuclear power system.

  18. Magnetic Surveys for Mapping of Ultramafic Bodies on the Site of the Ohi Nuclear Power Station, Central Japan

    Science.gov (United States)

    Okuma, S.; Makino, M.; Miyakawa, A.; Nakatsuka, T.; Iwamori, A.; Tanaka, Y.; Kudo, S.; Yanagida, M.; Sasaki, T.; Sugimori, T.; Kitao, H.; Asahi, N.; Shiomi, T.; Higashida, Y.

    2016-12-01

    The Ohi nuclear power station is located at the northern Oshima Peninsula in the Wakasa Bay on the coast of Japan Sea, central Japan. The geology of the site of the power station is composed mainly of shales, diabases, gabbros and ultramafic rocks of the Paleozoic Yakuno Ophiolite. An evaluation of the power station on conformity to the new regulatory requirements for nuclear power plants has been conducted. Various surveys such as tectonic geomorphological, trenching and drilling were conducted to better understand the fracture zones in the gabbro and ultramafic complex. As a result, the fracture zones can be classified into two types: faults found only in the complex and landslides seen in the upper parts of the ultramafic bodies. Whereas, magnetic susceptibilities were measured for whole cores from drilling and the upper parts of the ultramafic bodies showed high magnetic susceptibilities (> 10-2 SI). To map the distribution of ultramafic bodies, we conducted magnetic surveys on ground and at sea around Daibahama beach in December 2015. A ground magnetic survey was carried out on a grid and along a specified line on a small peninsula and some reeves by using a proton magnetometer. A seaborne magnetic survey was also conducted by a small rubber boat on which a Cesium magnetometer was mounted. Both observed data were merged and an IGRF residual magnetic anomaly map was compiled. According to the map, several positive magnetic anomalies lie over the southeastern edge of the estimated distribution area of ultramafic bodies on land, while negative magnetic anomalies are dominant at the northwestern edge. Magnetic susceptibility and NRM measurements were carried out for columnar specimens sampled from drill cores. As a preliminary analysis, we conducted 2D modeling of the specific survey line on a basis of the rock magnetic measurements. A thin dipping-dike with a reverse magnetization can account for the observed magnetic anomalies. However there still remain

  19. 光伏电站功率预测系统开发与设计%Development and Design of Power Prediction System for Photovoltaic Power Station

    Institute of Scientific and Technical Information of China (English)

    王知嘉; 崔方; 程序

    2016-01-01

    为减轻光伏电站电能波动性和随机性对电网安全带来的影响,提出光伏电站功率预测系统基本方案,介绍该系统的技术要求、系统结构和各模块主要功能,阐述平台软件开发的主要技术特点;通过将该方案应用在我国西北多个光伏电站,其现场验证表明,方案具有较好的预测效果,对电网调度及光伏电站经济运行具有较好的指导意义。%In order to reduce the impact of power’s volatility and randomness of the photovoltaic power plant upon power grid safety, this paper puts forward a basic scheme of power prediction system for photovoltaic power station, and introduces the technical requirements, system configuration and main function of each module of the system, and discusses the main technical features of platform software development. The scheme has been applied in many PV power plants in the northwest of China. The field verification shows that the proposed scheme can produce reasonable prediction results, and it provides important guiding significance for power grid dispatching and economic operation of PV power plant.

  20. Electric Power Plants and Generation Stations, Power Plants - is a seperate layer, however, we have them included in local building layer as well, Published in 2010, 1:2400 (1in=200ft) scale, Effingham County Board Of Commissioners.

    Data.gov (United States)

    NSGIC GIS Inventory (aka Ramona) — This Electric Power Plants and Generation Stations dataset, published at 1:2400 (1in=200ft) scale, was produced all or in part from Orthoimagery information as of...

  1. Torrevaldaliga Nord power plant: one of the cleanest and most efficient coal-fired power stations worldwide

    Energy Technology Data Exchange (ETDEWEB)

    Arrighi, L.; Dentini, A. [Enel Generation, Rome (Italy); Pasini, S.; Toschi, M. [Enel Generation, Pisa (Italy); Guardiani, G.M. [Enel Generaton, Piacenza (Italy)

    2008-07-01

    In the light of market liberalisation Enel decided to switch the Torrevaldaliga Nord Power Plant from oil to coal firing. The new plant comprises three coal-fired units with a total capacity of about 1980 MW. Also in international comparison the project is among the most ambitious and advanced projects of its kind, both in terms of its technical and environmental characteristics. Construction activity started in March 2004 and the first unit will be in commercial operation at the end of 2008. (orig.)

  2. Practical experiences with animal fat as added fuel in the Ingolstadt power station; Praktische Erfahrungen bei der versuchsweisen Mitverbrennung von Tierfett im Kraftwerk Ingolstadt

    Energy Technology Data Exchange (ETDEWEB)

    Gerischer, C.N. [E.ON Kraftwerke GmbH, Kraftwerksgruppe Ingolstadt/Irsching, Grossmehring (Germany)

    2004-07-01

    In 2001 the market was overflowing with animal fat due to the discussion about the bovine spongiform encephalopathy disease. One solution was the use as additional fuel in power plants. The fundamental technical requirements existed in Ingolstadt power station. Economical considerations led to the decision to test animal fat as added fuel. The main experiences are presented and discussed. (orig.)

  3. Feasibility study and energy efficiency estimation of geothermal power station based on medium enthalpy water

    Directory of Open Access Journals (Sweden)

    Borsukiewicz-Gozdur Aleksandra

    2007-01-01

    Full Text Available In the work presented are the results of investigations regarding the effectiveness of operation of power plant fed by geothermal water with the flow rate of 100, 150, and 200 m3/h and temperatures of 70, 80, and 90 °C, i. e. geothermal water with the parameters available in some towns of West Pomeranian region as well as in Stargard Szczecinski (86.4 °C, Poland. The results of calculations regard the system of geothermal power plant with possibility of utilization of heat for technological purposes. Analyzed are possibilities of application of different working fluids with respect to the most efficient utilization of geothermal energy. .

  4. Electromembrane recycling of highly mineralized alkaline blowdown water from evaporative water treatment plants at thermal power stations

    Science.gov (United States)

    Chichirova, N. D.; Chichirov, A. A.; Lyapin, A. I.; Minibaev, A. I.; Silov, I. Yu.; Tolmachev, L. I.

    2016-12-01

    Thermal power stations (TPS) are the main source of highly mineralized effluents affecting the environment. An analysis of their water systems demonstrates that alkaline effluents prevail at TPSs. Extraction of an alkali from highly mineralized effluents can make the recycling of effluents economically feasible. A method is proposed of electromembrane recycling of liquid alkaline highly mineralized wastes from TPSs. The process includes electromembrane apparatuses of two types, namely, a diffusion dialysis extractor (DDE) intended for extraction of the alkali from a highly mineralized solution having a complex composition and an electrodialysis concentrator for increasing the concentration of the extracted solution to a value suitable for use in water treatment plants at TPSs. For implementation of the first process (i.e. the extraction of alkali from alkaline-salt solution) various membranes from various manufacturers were studied: CM-PAD and AM-PAD (Ralex, Czechia), MK-40, MA-40, MA-41, MA-414, and MB-2 (OOO OKhK "Shchekinoazot", Russia), AR103-QDF and CR61-CMP (Ionies Inc., USA). The experiments demonstrate that the acceptable degree of separation of the alkali and the salt is achieved in a pair of cation-exchange membranes with the efficiency of separation being higher without an electric field. The highest efficiency was attained with Russian-made membranes (MK-40, OOO OKhK "Shchekinoazot"). A full scale experiment on recycling of highly-mineralized blowdown water from the evaporating water treatment system at the Kazan cogeneration power station No. 3 (TETs-3) was performed in a pilot unit consisting of two electromembrane apparatuses made by UAB "Membraninės Technologijos LT". In the experiments every ton of blowdown water yielded 0.1 t of concentrated alkaline solution with an alkali content of up to 4 wt % and 0.9 t of the softened salt solution suitable for the reuse in the TPS cycle. The power rate is 6 kWh / ton of blowdown water.

  5. Energy and Resources Group, University of California, Berkeley.

    Science.gov (United States)

    Christensen, Mark N.

    1987-01-01

    Describes an interdisciplinary program at the University of California (Berkeley) that addresses the multifaceted problems of energy and resources through a teaching and resource program. Discusses the program's structure, curriculum, research activities, students, resources, and problems and possibilities. (TW)

  6. Energy and Resources Group, University of California, Berkeley.

    Science.gov (United States)

    Christensen, Mark N.

    1987-01-01

    Describes an interdisciplinary program at the University of California (Berkeley) that addresses the multifaceted problems of energy and resources through a teaching and resource program. Discusses the program's structure, curriculum, research activities, students, resources, and problems and possibilities. (TW)

  7. Former Fermilab boss to lead Lawrence Berkeley National Laboratory

    Science.gov (United States)

    Gwynne, Peter

    2016-03-01

    Particle physicist Michael Witherell - current vice-chancellor for research at the University of California, Santa Barbara (UCSB) - has been appointed the next director of the Lawrence Berkeley National Laboratory (LBL).

  8. 76 FR 48184 - Exelon Nuclear, Peach Bottom Atomic Power Station, Unit 1; Exemption From Certain Security...

    Science.gov (United States)

    2011-08-08

    ... a permanently shut down nuclear reactor facility. PBAPS Unit 1 was a high-temperature, gas-cooled... nuclear power reactors against radiological sabotage,'' paragraph (b)(1) states, ``The licensee shall... its objective to provide high assurance that activities involving special nuclear material are...

  9. 77 FR 50533 - Dominion Nuclear Connecticut, Inc.; Millstone Power Station, Unit 3

    Science.gov (United States)

    2012-08-21

    ... the ECCS for reactors that have fuel rods fabricated either with Zircaloy or ZIRLO\\TM\\. Appendix K to... systems for light-water nuclear power reactors,'' and Appendix K to 10 CFR Part 50, ``ECCS Evaluation Models,'' to allow the use of Optimized ZIRLO\\TM\\ fuel rod cladding in future core reload...

  10. Tampa Electric Company, Polk Power Station Unit No. 1. Annual report, January--December 1992

    Energy Technology Data Exchange (ETDEWEB)

    None

    1993-10-01

    As part of the Tampa Electric Polk Power Unit No. 1, a Texaco pressurized, oxygen-blown entrained-flow coal gasifier will convert approximately 2300 tons per day of coal (dry basis) into a medium-BTU fuel gas with a heat content of about 250 BTU/scf (LHV). Syngas produced in the gasifier flows through a high-temperature heat recovery unit which cools the gases prior to entering two parallel clean-up areas. A portion (up to 50%) of the hot syngas is cooled to 1000{degrees}F and passed through a moving bed of zinc titanate sorbent which removed sulfur containing components of the fuel gas. The project will be the first in the world to demonstrate this advanced metal oxide hot gas desulfurization technology at a commercial scale. The remaining portion of the syngas is cooled to 400{degrees}F for conventional acid gas removal. This portion of the plant is capable of processing between 50% and 100% of the dirty syngas. The cleaned low-BTU syngas is then routed to the combined cycle power generation system where it is mixed with air and burned in the gas turbine combustor. Heat is extracted from the expanded exhaust gases by a heat recovery steam generator to produce high pressure steam. This steam, along with the steam generated in the gasification process, drives a steam turbine to generate an additional 132MW of power. Internal process power consumption is approximately 62MW, and includes power for coal grinding, air separation, and feed pumps. Net output from the IGCC demonstration plant will be 260MW.

  11. Annual environmental monitoring report of the Lawrence Berkeley Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Schleimer, G.E.; Pauer, R.O. (eds.)

    1990-08-01

    The Lawrence Berkeley Laboratory (LBL) is a multiprogram national laboratory managed by the University of California (UC) for the US Department of Energy (DOE). LBL's major role is to conduct basic and applied science research that is appropriate for an energy research laboratory. The Environmental Monitoring Program of the Lawrence Berkeley Laboratory is described. Data for 1989 are presented, and general trends are discussed. 17 refs., 12 figs., 23 tabs.

  12. A study of the old galactic star cluster Berkeley 32

    CERN Document Server

    Richtler, T; Richtler, Tom; Sagar, Ram

    2001-01-01

    We present new CCD photometry of the distant old open star cluster Berkeley 32 in Johnson V and Cousins I passbands. A total of about 3200 stars have been observed in a field of 13X13 arcmin**2. The colour-magnitude diagram in V, (V-I) has been generated down to V = 22 mag. A broad but well defined main sequence is clearly visible. Some blue stragglers, a well developed subgiant branch and a Red Clump are also seen. By fitting isochrones to this CMD as well as to other CMDs available in the literature, and using the Red Clump location, the reddening, distance and age of the star cluster have been determined. The cluster has a distance of 3.3 kpc, its radius is about 2.4 pc; the reddening E(B-V) is 0.08 mag and the age is 6.3 Gyr. By comparison with theoretical isochrones, a metallicity of [Fe/H]= -0.2 dex has been estimated. We find a much flatter mass function than what has been found for young clusters. If the mass function is a power law dN/dm = const.*m**alpha, then we get alpha = -0.5+-0.3 in the mass ra...

  13. The berkeley wavelet transform: a biologically inspired orthogonal wavelet transform.

    Science.gov (United States)

    Willmore, Ben; Prenger, Ryan J; Wu, Michael C-K; Gallant, Jack L

    2008-06-01

    We describe the Berkeley wavelet transform (BWT), a two-dimensional triadic wavelet transform. The BWT comprises four pairs of mother wavelets at four orientations. Within each pair, one wavelet has odd symmetry, and the other has even symmetry. By translation and scaling of the whole set (plus a single constant term), the wavelets form a complete, orthonormal basis in two dimensions. The BWT shares many characteristics with the receptive fields of neurons in mammalian primary visual cortex (V1). Like these receptive fields, BWT wavelets are localized in space, tuned in spatial frequency and orientation, and form a set that is approximately scale invariant. The wavelets also have spatial frequency and orientation bandwidths that are comparable with biological values. Although the classical Gabor wavelet model is a more accurate description of the receptive fields of individual V1 neurons, the BWT has some interesting advantages. It is a complete, orthonormal basis and is therefore inexpensive to compute, manipulate, and invert. These properties make the BWT useful in situations where computational power or experimental data are limited, such as estimation of the spatiotemporal receptive fields of neurons.

  14. Implications of climate change on the heat budget of lentic systems used for power station cooling: Case study Clinton Lake, Illinois

    Science.gov (United States)

    Quijano, Juan C; Jackson, P. Ryan; Santacruz, Santiago; Morales, Viviana M; Garcia, Marcelo H.

    2016-01-01

    We use a numerical model to analyze the impact of climate change--in particular higher air temperatures--on a nuclear power station that recirculates the water from a reservoir for cooling. The model solves the hydrodynamics, the transfer of heat in the reservoir, and the energy balance at the surface. We use the numerical model to (i) quantify the heat budget in the reservoir and determine how this budget is affected by the combined effect of the power station and climate change and (ii) quantify the impact of climate change on both the downstream thermal pollution and the power station capacity. We consider four different scenarios of climate change. Results of simulations show that climate change will reduce the ability to dissipate heat to the atmosphere and therefore the cooling capacity of the reservoir. We observed an increase of 25% in the thermal load downstream of the reservoir, and a reduction in the capacity of the power station of 18% during the summer months for the worst-case climate change scenario tested. These results suggest that climate change is an important threat for both the downstream thermal pollution and the generation of electricity by power stations that use lentic systems for cooling.

  15. Implications of Climate Change on the Heat Budget of Lentic Systems Used for Power Station Cooling: Case Study Clinton Lake, Illinois.

    Science.gov (United States)

    Quijano, Juan C; Jackson, P Ryan; Santacruz, Santiago; Morales, Viviana M; García, Marcelo H

    2016-01-05

    We use a numerical model to analyze the impact of climate change-in particular higher air temperatures-on a nuclear power station that recirculates the water from a reservoir for cooling. The model solves the hydrodynamics, the transfer of heat in the reservoir, and the energy balance at the surface. We use the numerical model to (i) quantify the heat budget in the reservoir and determine how this budget is affected by the combined effect of the power station and climate change and (ii) quantify the impact of climate change on both the downstream thermal pollution and the power station capacity. We consider four different scenarios of climate change. Results of simulations show that climate change will reduce the ability to dissipate heat to the atmosphere and therefore the cooling capacity of the reservoir. We observed an increase of 25% in the thermal load downstream of the reservoir, and a reduction in the capacity of the power station of 18% during the summer months for the worst-case climate change scenario tested. These results suggest that climate change is an important threat for both the downstream thermal pollution and the generation of electricity by power stations that use lentic systems for cooling.

  16. VIBRATION SENSOR FOR HEALTH MONITORING OF ELECTRICAL MACHINES IN POWER STATION

    Directory of Open Access Journals (Sweden)

    Neha Gupta

    2012-04-01

    Full Text Available Vibration monitoring in high power electric machines, such as generators and transformers, presents some difficulties due to the insulation and EM immunity requirements .However, the negative influence of the electromagnetic interference (EMI can be a real problem when electrical signals are used to detect and transmitphysical parameters in noisy environments such as electric power generator plants with high levels of EMI. Such problems can be solved using optical fiber sensors, which allow in situ measurements and remote control without electrical wires. The present paper describes a novel fiber optic vibration sensor for health monitoring of electrical machines, which utilizes relatively simple technologies and offers moderate costs. The sensor is optimized for detection of mechanical vibrations in the frequency range 20-100 Hz. Design details and experimental results are reported.

  17. Rancang Bangun Maximum Power Point Tracking pada Panel Photovoltaic Berbasis Logika Fuzzy di Buoy Weather Station

    OpenAIRE

    Bayu Prima Juliansyah Putra; Aulia Siti Aisjah; Syamsul Arifin

    2013-01-01

    Salah satu aplikasi yang sering digunakan dalam bidang energi terbarukan adalah panel photovoltaic. Panel ini memiliki prinsip kerja berdasarkan efek photovoltaic dimana lempengan logam akan menghasilkan energi listrik apabila diberi intensitas cahaya. Untuk menghasilkan daya keluaran panel yang maksimal, maka diperlukan suatu algoritma yang biasa disebut Maximum Power Point Tracking (MPPT).MPPT yang diterapkan pada sistem photovoltaic berfungsi untuk mengatur nilai tegangan keluaran panel se...

  18. [Hygienic problems in the location of modern wind electric power stations in their design].

    Science.gov (United States)

    Kireeva, I S; Makhniuk, V M; Akimenko, V Ia; Dumanskiĭ, Iu D; Semashko, P V

    2013-01-01

    Hygienic aspects of the placement of wind power plants (WPP) in connection with the intensive development of wind power and the lack of systematic information on their effects of the environment and living conditions of the population are becoming more actual. In the article there are considered results of the sanitary-epidemiological expertise of the construction project of three modern large wind farm (the South - Ukrainian, Tiligulskaya and Pokrovskaya) with a total capacity offrom 180 to 500 MW of wind farms with 2.3 MW power generators of wind turbines. It is shown that in the process of wind farm construction a contamination of the environment (air soil, ground water) may take place due to the working of construction equipment and vehicle, excavation, welding and other operations, in the exploitation of wind farm there can be created elevated levels of acoustic and electromagnetic pollution in the neighborhood and emergencies with the destruction of WPP in adverse weather conditions. Based on the calculations presented in the projects, and the analysis of data on the impact offoreign windfarm on the environment it was found that the limiting factor of the influence is the wind farm noise pollution in the audio frequency range that extends beyond the territory of wind fields, electromagnetic radiation is recorded within the hygienic standards and below only in the immediate vicinity of its sources (electrical equipment and power lines). For considered modern wind farms there was grounded sanitary protective zone with dimensions of 700 mfrom the outermost wind turbines by the noise and it was recommended compliance distance of200 mfrom the wind turbine to limit any activity and people staying in times of possible emergency situations in adverse weather conditions.

  19. Organohalogen products from chlorination of cooling water at nuclear power stations

    Energy Technology Data Exchange (ETDEWEB)

    Bean, R.M.

    1983-10-01

    Eight nuclear power units at seven locations in the US were studied to determine the effects of chlorine, added as a biocide, on the composition of cooling water discharge. Water, sediment and biota samples from the sites were analyzed for total organic halogen and for a variety of organohalogen compounds. Haloforms were discharged from all plants studied, at concentrations of a few ..mu..g/L (parts-per-billion). Evidence was obtained that power plants with cooling towers discharge a significant portion of the haloforms formed during chlorination to the atmosphere. A complex mixture of halogenated phenols was found in the cooling water discharges of the power units. Cooling towers can act to concentrate halogenated phenols to levels approaching those of the haloforms. Examination of samples by capillary gas chromatography/mass spectrometry did not result in identification of any significant concentrations of lipophilic base-neutral compounds that could be shown to be formed by the chlorination process. Total concentrations of lipophilic (Bioabsorbable) and volatile organohalogen material discharged ranged from about 2 to 4 ..mu..g/L. Analysis of sediment samples for organohalogen material suggests that certain chlorination products may accumulate in sediments, although no tissue bioaccumulation could be demonstrated from analysis of a limited number of samples. 58 references, 25 figures, 31 tables.

  20. Prediction of SO{sub 2} pollution incidents near a power station using partially linear models and an historical matrix of predictor-response vectors

    Energy Technology Data Exchange (ETDEWEB)

    Prada-Sanchez, J.M.; Febrero-Bande, M.; Gonzalez-Manteiga, W. [Universidad de Santiago de Compostela, Dept. de Estadistica e Investigacion Operativa, Santiago de Compostela (Spain); Costos-Yanez, T. [Universidad de Vigo, Dept. de Estadistica e Investigacion Operativa, Orense (Spain); Bermudez-Cela, J.L.; Lucas-Dominguez, T. [Laboratorio, Central Termica de As Pontes, La Coruna (Spain)

    2000-07-01

    Atmospheric SO{sub 2} concentrations at sampling stations near the fossil fuel fired power station at As Pontes (La Coruna, Spain) were predicted using a model for the corresponding time series consisting of a self-explicative term and a linear combination of exogenous variables. In a supplementary simulation study, models of this kind behaved better than the corresponding pure self-explicative or pure linear regression models. (Author)

  1. The collective dose equivalent in evaluated region of bone-coal power stations and bone-coal shafts

    Institute of Scientific and Technical Information of China (English)

    ZHANG Liang; JIANG Shan; KONG Ling-Li; LI Ying; YE Ji-Da; SHI Jin-Hua; WU Zong-Mei

    2005-01-01

    During 1991-1993, the radioactivity levels of the bone-coal mines were investigated in Hubei, Hunan, Jiangxi, Zhejiang and Anhui Provinces, respectively, where the reserve of bone-coal is about 90% of our country's total reserve. The annual additional collective dose equivalent within 80km evaluated region of bone-coal power stations in Nijiangkou and Anren is 1.7 and 1.9 man .mSv,respectively,and that of Zhuantanyan bone-coal shaft is 1.4 man.mSv.The collective dose equivalent caused by bone-coal cinder brick produced for 25 years in the provinces is 1.6×105 man.Sv.

  2. Organic Rankine Cycle for Residual Heat to Power Conversion in Natural Gas Compressor Station. Part I: Modelling and Optimisation Framework

    Science.gov (United States)

    Chaczykowski, Maciej

    2016-06-01

    Basic organic Rankine cycle (ORC), and two variants of regenerative ORC have been considered for the recovery of exhaust heat from natural gas compressor station. The modelling framework for ORC systems has been presented and the optimisation of the systems was carried out with turbine power output as the variable to be maximized. The determination of ORC system design parameters was accomplished by means of the genetic algorithm. The study was aimed at estimating the thermodynamic potential of different ORC configurations with several working fluids employed. The first part of this paper describes the ORC equipment models which are employed to build a NLP formulation to tackle design problems representative for waste energy recovery on gas turbines driving natural gas pipeline compressors.

  3. Discussion on water pump installation of thermal power station%谈热力站内水泵的安装

    Institute of Scientific and Technical Information of China (English)

    钱景

    2014-01-01

    结合工作实践经验,对热力站内常见水泵的安装过程作了较详细的叙述,并就水泵底数安装、电动机安装、管路安装等环节总结了几点安装注意事项,对类似工程有一定的参考价值。%Combining with working practice,the paper illustrates common water pump installation process of thermal power station,summarizes water pump bottom value installation,electrical machine installation and pipeline installation and other installation matters,which has certain guiding meaning for similar engineering.

  4. Process visualisation and multimedia for power station control of the future; Prozessvisualisierung und Multimedia fuer die Kraftwerksfuehrung von morgen

    Energy Technology Data Exchange (ETDEWEB)

    Herbst, L. [ABB Kraftwerksleittechnik GmbH, Mannheim (Germany)

    1994-11-14

    Advanced process control and modern process management require integration of many partial tasks. Advanced process control will include modern multi-media and communication technologies. The next generation of process control, developed by ABB had already been presented on trade fairs and includes large-screen projection, mass data visualisation and multimedia. This offers efficient, target-oriented and reliable power station control and integration of tasks. (orig.) [Deutsch] Fortschrittliche Prozessfuehrung und modernes Prozessmanagement erfordern die Integration vieler Teilaufgaben. Die Prozessfuehrung der Zukunft wird moderne Multimedia- und Kommunikationstechnologien enthalten. Die von ABB derzeit konzipierte, in Teilen bereits entwickelte und auf Messen praesentierte naechste Generation der Prozessfuehrung mit Grossbildprojektionen, Moeglichkeiten zur Massendatenvisualisierung und Multimedia ermoeglicht wirtschaftliche, zielgerichtete und zuverlaessige Kraftwerksfuehrung durch aufgabenvernetzte Zusammenarbeit. (orig.)

  5. Placement of Base Stations in Broadband Power Line Communications Access Networks by Means of Multi-criteria Optimization

    Science.gov (United States)

    Haidine, Abdelfatteh; Lehnert, Ralf

    Broadband Power Line Communications (B-PLC) technology is an alternative for broadband access networks, allowing bit rates up to currently 200Mbps. This technique uses the wiring of the low-voltage grid in order to offer to the users the telecommunications services, such as Internet, VoIP, VoD, etc. The B-PLC design process is sub-divided into two parts: the Generalized Base Station Placement (GBSP) problem and the PLC Channel Allocation Problem (P-CAP). This paper focuses on GBSP that is modeled as multi-criteria combinatorial optimization problem. Based on our published mathematical modeling, this paper supplies more numerical experiments for the evaluation of Multi-Objective Evolutionary Algorithms (MOEAs) in solving GBSP. Their performance is compared with the single-objective optimization.

  6. Investigation of Main Radiation Source above Shield Plug of Unit 3 at Fukushima Daiichi Nuclear Power Station

    Science.gov (United States)

    Hiratama, Hideo; Kondo, Kenjiro; Suzuki, Seishiro; Tanimura, Yoshihiko; Iwanaga, Kohei; Nagata, Hiroshi

    2017-09-01

    Pulse height distributions were measured using a CdZnTe detector inside a lead collimator to investigate main source producing high dose rates above the shield plugs of Unit 3 at Fukushima Daiichi Nuclear Power Station. It was confirmed that low energy photons are dominant. Concentrations of Cs-137 under 60 cm concrete of the shield plug were estimated to be between 8.1E+9 and 5.7E+10 Bq/cm2 from the measured peak count rate of 0.662 MeV photons. If Cs-137 was distributed on the surfaces of the gaps with radius 6m and with the averaged concentration of 5 points, 2.6E+10 Bq/cm2, total amount of Cs-137 is estimated to be 30 PBq.

  7. Investigation of Main Radiation Source above Shield Plug of Unit 3 at Fukushima Daiichi Nuclear Power Station

    Directory of Open Access Journals (Sweden)

    Hiratama Hideo

    2017-01-01

    Full Text Available Pulse height distributions were measured using a CdZnTe detector inside a lead collimator to investigate main source producing high dose rates above the shield plugs of Unit 3 at Fukushima Daiichi Nuclear Power Station. It was confirmed that low energy photons are dominant. Concentrations of Cs-137 under 60 cm concrete of the shield plug were estimated to be between 8.1E+9 and 5.7E+10 Bq/cm2 from the measured peak count rate of 0.662 MeV photons. If Cs-137 was distributed on the surfaces of the gaps with radius 6m and with the averaged concentration of 5 points, 2.6E+10 Bq/cm2, total amount of Cs-137 is estimated to be 30 PBq.

  8. Predictions of U.K. regulated power station contributions to regional air pollution and deposition: a model comparison exercise.

    Science.gov (United States)

    Chemel, Charles; Sokhi, Ranjeet S; Dore, Anthony J; Sutton, Paul; Vincent, Keith J; Griffiths, Stephen J; Hayman, Garry D; Wright, Raymond D; Baggaley, Matthew; Hallsworth, Stephen; Prain, H Douglas; Fisher, Bernard E A

    2011-11-01

    Contributions of the emissions from a U.K. regulated fossil-fuel power station to regional air pollution and deposition are estimated using four air quality modeling systems for the year 2003. The modeling systems vary in complexity and emphasis in the way they treat atmospheric and chemical processes, and include the Community Multiscale Air Quality (CMAQ) modeling system in its versions 4.6 and 4.7, a nested modeling system that combines long- and short-range impacts (referred to as TRACK-ADMS [Trajectory Model with Atmospheric Chemical Kinetics-Atmospheric Dispersion Modelling System]), and the Fine Resolution Atmospheric Multi-pollutant Exchange (FRAME) model. An evaluation of the baseline calculations against U.K. monitoring network data is performed. The CMAQ modeling system version 4.6 data set is selected as the reference data set for the model footprint comparison. The annual mean air concentration and total deposition footprints are summarized for each modeling system. The footprints of the power station emissions can account for a significant fraction of the local impacts for some species (e.g., more than 50% for SO2 air concentration and non-sea-salt sulfur deposition close to the source) for 2003. The spatial correlation and the coefficient of variation of the root mean square error (CVRMSE) are calculated between each model footprint and that calculated by the CMAQ modeling system version 4.6. The correlation coefficient quantifies model agreement in terms of spatial patterns, and the CVRMSE measures the magnitude of the difference between model footprints. Possible reasons for the differences between model results are discussed. Finally, implications and recommendations for the regulatory assessment of the impact of major industrial sources using regional air quality modeling systems are discussed in the light of results from this case study.

  9. Damodar Valley Corporation, Chandrapura Unit 2 Thermal Power Station Residual Life Assessment Summary report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-02-01

    The BHEL/NTPC/PFC/TVA teams assembled at the DVC`s Chadrapura station on July 19, 1994, to assess the remaining life of Unit 2. The workscope was expanded to include major plant systems that impact the unit`s ability to sustain generation at 140 MW (Units 1-3 have operated at average rating of about 90 MW). Assessment was completed Aug. 19, 1994. Boiler pressure parts are in excellent condition except for damage to primary superheater header/stub tubes and economizer inlet header stub tubes. The turbine steam path is in good condition except for damage to LP blading; the spar rotor steam path is in better condition and is recommended for Unit 2. Nozzle box struts are severely cracked from the flame outs; the cracks should not be repaired. HP/IP rotor has surface cracks at several places along the steam seal areas; these cracks are shallow and should be machined out. Detailed component damage assessments for above damaged components have been done. The turbine auxiliary systems have been evaluated; cooling tower fouling/blockage is the root cause for the high turbine back pressure. The fuel processing system is one of the primary root causes for limiting unit capacity. The main steam and hot reheat piping systems were conservatively designed and have at least 30 years left;deficiencies needing resolution include restoration of insulation, replacement of 6 deformed hanger clamp/bolts, and adjustment of a few hanger settings. The cold reheat piping system is generally in good condition; some areas should be re-insulated and the rigid support clamps/bolts should be examined. The turbine extraction piping system supports all appeared to be functioning normally.

  10. Techno-Economic Evaluation of a Stand-Alone Power System Based on Solar Power/Batteries for Global System for Mobile Communications Base Stations

    Directory of Open Access Journals (Sweden)

    Mohammed H. Alsharif

    2017-03-01

    Full Text Available Energy consumption in cellular networks is receiving significant attention from academia and the industry due to its significant potential economic and ecological influence. Energy efficiency and renewable energy are the main pillars of sustainability and environmental compatibility. Technological advancements and cost reduction for photovoltaics are making cellular base stations (BSs; a key source of energy consumption in cellular networks powered by solar energy sources a long-term promising solution for the mobile cellular network industry. This paper addresses issues of deployment and operation of two solar-powered global system for mobile communications (GSM BSs that are being deployed at present (GSM BS 2/2/2 and GSM BS 4/4/4. The study is based on the characteristics of South Korean solar radiation exposure. The optimum criteria as well as economic and technical feasibility for various BSs are analyzed using a hybrid optimization model for electric renewables. In addition, initial capital, replacement, operations, maintenance, and total net present costs for various solar-powered BSs are discussed. Furthermore, the economic feasibility of the proposed solar system is compared with conventional energy sources in urban and remote areas.

  11. Rebuilding the Chalberhoeni small hydro power station in Saanen, Switzerland; Chalberhoeni - Rapport Final

    Energy Technology Data Exchange (ETDEWEB)

    Cavin, G. [Stucky SA, Renens (Switzerland); Wagner, T. [Sigmaplan, Berne (Switzerland)

    2009-07-01

    These two final illustrated reports for the Swiss Federal Office of Energy (SFOE) deal with various aspects of the Chalberhoeni small hydro project in Saanen, Switzerland. The first report presents data on the catchment area involved, available head, residual water quantities, installed power and annual production figures. Investments and operating costs are looked at. The second report describes the project and discusses regional planning aspects, hydrological basics and environmental issues in connection with the renewal project, including details on invertebrates found in the stream and their relevance to fishing and nature protection issues.

  12. Ernest Orlando Berkeley National Laboratory - Fundamental and applied research on lean premixed combustion

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Robert K.

    1999-07-07

    Ernest Orland Lawrence Berkeley National Laboratory (Berkeley Lab) is the oldest of America's national laboratories and has been a leader in science and engineering technology for more than 65 years, serving as a powerful resource to meet Us national needs. As a multi-program Department of Energy laboratory, Berkeley Lab is dedicated to performing leading edge research in the biological, physical, materials, chemical, energy, environmental and computing sciences. Ernest Orlando Lawrence, the Lab's founder and the first of its nine Nobel prize winners, invented the cyclotron, which led to a Golden Age of particle physics and revolutionary discoveries about the nature of the universe. To this day, the Lab remains a world center for accelerator and detector innovation and design. The Lab is the birthplace of nuclear medicine and the cradle of invention for medical imaging. In the field of heart disease, Lab researchers were the first to isolate lipoproteins and the first to determine that the ratio of high density to low density lipoproteins is a strong indicator of heart disease risk. The demise of the dinosaurs--the revelation that they had been killed off by a massive comet or asteroid that had slammed into the Earth--was a theory developed here. The invention of the chemical laser, the unlocking of the secrets of photosynthesis--this is a short preview of the legacy of this Laboratory.

  13. Discussion on the management mode of unattended thermal power station%无人值守热力站管理模式探讨

    Institute of Scientific and Technical Information of China (English)

    孟慧秀

    2015-01-01

    介绍了集中供热系统无人值守热力站自动定压补水系统的设置流程,并从设备设施、定期巡视、供热调节、监测数据等角度出发,探讨了无人值守热力站的管理模式,以保证无人值守热力站高效、安全、平稳地运行。%This paper introduced the setting process of automatic constant pressure water supply system of unattended thermal power station of central heating system,and from the equipment and facilities,regular inspection,heating regulation,monitoring data etc. ,discussed the man-agement mode of unattended thermal power station,to ensure the efficiency,security,stability operation of unattended thermal power station.

  14. Implementation of the BayBIS process information system in a power station at minimal cost; Die kostenminimale Realisierung des Prozessinformationssystems BayBIS fuer einen Kraftwerksbetreiber

    Energy Technology Data Exchange (ETDEWEB)

    Woyke, W.

    2000-07-01

    BKW are currently introducing the process information system BayBIS (Bayernwerk Betriebsinformationssystem) in three of their power stations. It was developed for a BKW medium-capacity power station where it was installed one year ago. The measuring and data acquisition systems of the power stations can be utilized for BayBIS. It is based on well-establilshed methods and makes use of the available IT systems. It is applied for process monitoring, process analysis, billing, controlling and reporting. [German] Die BKW fuehrt derzeit fuer drei Kraftwerke das Prozessinformationssystem BayBIS (Bayernwerk Betriebsinformationssystem) ein. Es wurde fuer ein Mittellastkraftwerk der BKW entwickelt und ist dort bereits seit einem Jahr im Einsatz. Messtechnik und prozessnahe Datenerfassung der Leittechnik in den Kraftwerken koennen fuer BayBIS genutzt werden. Es baut auf Methoden auf, die sich in der Praxis bewaehrt haben, und nutzt die vorhandene IT-Ausstattung des Unternehmens. Anwendung findet es fuer Prozessbeobachtung, Prozessanalyse, Abrechnung, Controlling und Berichtswesen. (orig.)

  15. Lawrence Berkeley Laboratory, Berkeley, California solar energy system performance evaluation, July 1980-June 1981

    Energy Technology Data Exchange (ETDEWEB)

    Wetzel, P.E.

    1981-01-01

    The Lawrence Berkeley Laboratory site is an office building in California with an active solar energy system designed to supply from 23 to 33% of the space heating load and part of the hot water load. The solar heating system is equipped with 1428 square feet of flat-plate collectors, a 2000-gallon water storage tank, and two gas-fired boilers to supply auxiliary heat for both space heating and domestic hot water. Poor performance is reported, with the solar fraction being only 4%. Also given are the solar savings ratio, conventional fuel savings, system performance factor, and the coefficient of performance. The performance data are given for the collector, storage, solar water heating and solar space heating subsystems as well as the total system. Typical system operation and solar energy utilization are briefly described. The system design, performance evaluation techniques, weather data, and sensor technology are presented. (LEW)

  16. Techniques to determine ignition, flame stability and burnout of blended coals in p.f. power station boilers

    Energy Technology Data Exchange (ETDEWEB)

    Su, S.; Pohl, J.H.; Holcombe, D.; Hart, J.A. [University of Queensland, Brisbane, Qld. (Australia). Dept. of Chemical Engineering

    2001-07-01

    The blending of coals has become popular to improve the performance of coals, to meet specifications of power plants and to reduce the cost of coals. This article reviews the results and provides new information on ignition, flame stability, and carbon burnout studies of blended coals. The reviewed studies were conducted in laboratory-, pilot-, and full-scale facilities. The new information was taken in pilot-scale studies. The results generally show that blending a high-volatile coal with a low-volatile coal or anthracite can improve the ignition, flame stability and burnout of the blends. This paper discusses two general methods to predict the performance of blended coals: (1) experiment; and (2) indices. Laboratory- and pilot-scale tests, at least, provide a relative ranking of the combustion performance of coal/blends in power station boilers. Several indices, volatile matter content, heating value and a maceral index, can be used to predict the relative ranking of ignitability and flame stability of coals and blends. The maceral index, fuel ratio, and vitrinite reflectance can also be used to predict the absolute carbon burnout of coal and blends within limits. 59 refs., 20 figs., 4 tabs.

  17. Measurement of the magnetic properties of P9 and T22 steel taken from service in power station

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, J.W., E-mail: John.Wilson@manchester.ac.uk [School of Electrical and Electronic Engineering, University of Manchester, Manchester M13 9PL (United Kingdom); Karimian, N. [School of Electrical and Electronic Engineering, University of Manchester, Manchester M13 9PL (United Kingdom); Liu, J. [School of Metallurgy and Materials, University of Birmingham, Edgbaston, Birmingham B15 2TT (United Kingdom); Yin, W. [School of Electrical and Electronic Engineering, University of Manchester, Manchester M13 9PL (United Kingdom); Davis, C.L. [School of Metallurgy and Materials, University of Birmingham, Edgbaston, Birmingham B15 2TT (United Kingdom); Peyton, A.J. [School of Electrical and Electronic Engineering, University of Manchester, Manchester M13 9PL (United Kingdom)

    2014-06-01

    With the UK's aging power generation network, life-extension of steel plant components is a critical issue. However, in order to evaluate the likelihood of component failure, techniques must be developed to properly assess the level of degradation in power station steels. Electromagnetic inspection has the potential to quantify the level of degradation through in-situ measurements at elevated temperatures. This paper reports the results of tests carried out on thermally treated P9 and T22 steel samples with different microstructural states using major and minor B–H loop measurements and magnetic Barkhausen noise measurements. The results show that by careful selection of minor loop parameters, specific to the material under inspection and the material change under consideration, correlations can established between EM properties and material properties such as Vickers hardness. These results will be used as a basis for the further development of a fully field deployable device. - Highlights: • T22 and P9 steel samples thermally treated to create different microstructures. • Major and minor BH loop and Barkhausen noise signals measured. • Permeability curves derived from three different types of minor loop. • Minor loop Barkhausen noise shows loop amplitude required to overcome pinning sites. • Correlations established between EM signal features and Vickers hardness.

  18. The bioaccumulation of heavy metals in Brassica napus L. in the area around Turów Power Station, Poland

    Directory of Open Access Journals (Sweden)

    Niedźwiecka Alicja

    2017-01-01

    Full Text Available Brassica napus L. is a known bioaccumulator of copper, zinc, cadmium, lead, chromium, nickel and arsenic from soils. The metal ions are accumulated in the roots, stems, leaves and seeds of the oilseed rape. The samples of soils and plants were collected in the area around the Turów power station (Bogatynia city, Lower Silesia. The soil samples were collected from the surface layer of 0-25 cm. Roots, stems and pods of the oilseed rape were used in the study. The environmental samples were digested in HNO3, 60%, using the Microwave Digestion System. Metal concentrations have been dermined through the FAAS method. Three heavy metals - zinc, copper and lead – have been analyzed. The content of zinc was higher than the content of copper in all samples (plants and soils. In the roots of the oilseed rape higher concentration of metals compared to other parts of the plant was observed. In the soil samples, there was no correlation between the concentration of pollution and the distance from the power plant. Permissible concentrations of heavy metals relative to the standard according to the Polish Ministry of Environment Regulation from September 1st, 2016, have not been exceeded. The permissible pollution indexes (Wn in soils were exceeded compared to the geochemical background in uncontaminated soils of Poland. The bioaccumulation coefficients of heavy metals indicate lower metal concentrations in plants than in soils

  19. MEASUREMENTS OF THE CONFINEMENT LEAKTIGHTNESS AT THE KOLA NUCLEAR POWER STATION (UNIT 2) IN RUSSIA

    Energy Technology Data Exchange (ETDEWEB)

    GREENE,G.A.; GUPPY,J.G.

    1998-08-01

    This is the final report on the INSP project entitled, ``Kola Confinement Leaktightness'' conducted by BNL under the authorization of Project Work Plan WBS 1.2.2.1. This project was initiated in February 1993 to assist the Russians to reduce risks associated with the continued operation of older Soviet-designed nuclear power plants, specifically the Kola VVER-440/230 Units 1 and 2, through upgrades in the confinement performance to reduce the uncontrolled leakage rate. The major technical objective of this-project was to improve the leaktightness of the Kola NPP VVER confinement boundaries, through the application of a variety of sealants to penetrations, doors and hatches, seams and surfaces, to the extent that current technology permitted. A related objective was the transfer, through training of Russian staff, of the materials application procedures to the staff of the Kola NPP. This project was part of an overall approach to minimizing uncontrolled releases from the Kola NPP VVER440/230s in the event of a serious accident, and to thereby significantly mitigate the consequences of such an accident. The US provided materials, application technology, and applications equipment for application of sealant materials, surface coatings, potting materials and gaskets, to improve the confinement leaktightness of the Kola VVER-440/23Os. The US provided for training of Russian personnel in the applications technology.

  20. Performance Assessment of a Solar powered Air Quality and Weather Station Placed on a School Rooftop in Hong Kong

    Science.gov (United States)

    Summary of compact, roof version of a Village Green Project station installed on a secondary school rooftop in Hong Kong. Preliminary comparison of the station's data against nearby regulatory monitors are summarized.

  1. 700-MW coal fired sliding pressure operation boiler with improving operational characteristics. ; Chubu Electric Power Co. Inc. Hekinan thermal power station

    Energy Technology Data Exchange (ETDEWEB)

    Matsuda, J.; Kiyama, K. (Babcock-Hitachi K.K., Tokyo (Japan))

    1993-02-01

    In response to requirements of improvements of efficiency and operability to provide demand control and environmental preservation in coal fired boilers, Babcock-Hitachi has endeavored to develop a large capacity coal fired boiler. As a result, Babcock-Hitachi has installed a 700MW supercritical sliding pressure operation coal fired once through boiler at the Hekinan Thermal Power Station Unit No.2 of Chubu Electric Power Co. For this coal fired boiler, spiral water wall construction was adopted to stabilize the furnace outlet water temperature via uniform heat absorption at the furnace. A three-stage spray-type attemperator was also applied to the main steam temperature control to improve load controllability and to correspond to a fluctuation of heat absorption at the furnace and the convection pass zone. Moreover, gas recirculation system, parallel gas damper, and intermediate spray attemperator were used to control the reheat steam temperature. The present article describes design summary and results of trial operation of this large capacity coal fired boiler. 11 figs., 3 tabs.

  2. Control system for the 2nd generation Berkeley automounters (BAM2) at GM/CA-CAT macromolecular crystallography beamlines

    Energy Technology Data Exchange (ETDEWEB)

    Makarov, O., E-mail: makarov@anl.gov [GM/CA-CAT, Biosciences Division, Argonne National Laboratory, Argonne, IL 60439 (United States); Hilgart, M.; Ogata, C.; Pothineni, S. [GM/CA-CAT, Biosciences Division, Argonne National Laboratory, Argonne, IL 60439 (United States); Cork, C. [Physical Biosciences Division, Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States)

    2011-09-01

    GM/CA-CAT at Sector 23 of the Advanced Photon Source (APS) is an NIH funded facility for crystallographic structure determination of biological macromolecules by X-ray diffraction. A second-generation Berkeley automounter is being integrated into the beamline control system at the 23BM experimental station. This new device replaces the previous all-pneumatic gripper motions with a combination of pneumatics and XYZ motorized linear stages. The latter adds a higher degree of flexibility to the robot including auto-alignment capability, accommodation of a larger capacity sample Dewar of arbitrary shape, and support for advanced operations such as crystal washing, while preserving the overall simplicity and efficiency of the Berkeley automounter design.

  3. Control structures design for fossil power station units; Diseno de estructuras de control para unidades termoelectricas

    Energy Technology Data Exchange (ETDEWEB)

    Palomares Gonzalez, Daniel; Ricano Castillo, Juan Manuel [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1989-12-31

    In this paper are designed an analyzed the control ties of a 300MW fossil unit at different operation levels. The design and analysis were developed on an operation range of 50% to 100% load. The main control ties were studied among which are the feedwater flow, the superheating zone temperatures and the generated output. The technique used for the design is the decomposition in singular values (DSV) of the plant transference matrix. This is a recent technique that permits finding the most important interactions among output-input variables, over a significative frequencies range for the transference matrix of the plant. For this purpose utilizes the control properties of the transference matrix, such as: control effort, output-input interaction and ruggedness with respect to uncertainties. The control structures obtained were tested in a digital model of a fossil plant unit. A comparison study of both structures (original and modified) showed enhancement in the performance of the power plant with modified structure. [Espanol] En este trabajo se disenan y analizan los lazos de control de una unidad termoelectrica de 300 MW, a diferentes niveles de operacion. El diseno y analisis se desarrollo sobre un rango de operacion de 50 a 100 por ciento de carga. Se estudiaron los principales lazos de control entre los que se encuentran el flujo de agua de alimentacion, las temperaturas de la zona de sobrecalentamiento y la potencia generada. La tecnica utilizada para el diseno es la descomposicion en valores singulares (DVS) de la matriz de transferencia de la planta. Esta es una tecnica reciente que permite encontrar las interacciones mas importantes entre variables entrada-salida, sobre un rango de frecuencias significativas para la matriz de transferencia de la planta. Utiliza para ello las propiedades de control de la matriz de transferencia, como son: esfuerzo de control, interaccion entrada-salida y robustez con respecto a incertidumbres. Las estructuras de control

  4. Short-term pressure and temperature MSLB response analyses for large dry containment of the Maanshan nuclear power station

    Energy Technology Data Exchange (ETDEWEB)

    Dai, Liang-Che, E-mail: lcdai@iner.gov.tw; Chen, Yen-Shu; Yuann, Yng-Ruey

    2014-12-15

    Highlights: • The GOTHIC code is used for the PWR dry containment pressure and temperature analysis. • Boundary conditions are hot standby and 102% power main steam line break accidents. • Containment pressure and temperature responses of GOTHIC are similar with FSAR. • The capability of the developed model to perform licensing calculation is assessed. - Abstract: Units 1 and 2 of the Maanshan nuclear power station are the typical Westinghouse three-loop PWR (pressurized water reactor) with large dry containments. In this study, the containment analysis program GOTHIC is adopted for the dry containment pressure and temperature analysis. Free air space and sump of the PWR dry containment are individually modeled as control volumes. The containment spray system and fan cooler unit are also considered in the GOTHIC model. The blowdown mass and energy data of the main steam line break (hot standby condition and various reactor thermal power levels) are tabulated in the Maanshan Final Safety Analysis Report (FSAR) 6.2 which could be used as the boundary conditions for the containment model. The calculated containment pressure and temperature behaviors of the selected cases are in good agreement with the FSAR results. In this study, hot standby and 102% reactor thermal power main steam line break accidents are selected. The calculated peak containment pressure is 323.50 kPag (46.92 psig) for hot standby MSLB, which is a little higher than the FSAR value of 311.92 kPag (45.24 psig). But it is still below the design value of 413.69 kPag (60 psig). The calculated peak vapor temperature inside the containment is 187.0 °C (368.59 F) for 102% reactor thermal power MSLB, which is lower than the FSAR result of 194.42 °C (381.95 F). The effects of the containment spray system and fan cooler units could be clearly observed in the GOTHIC analysis. The calculated containment pressure and temperature behaviors of the selected cases are in good agreement with the FSAR

  5. The combined heating and power station of Moabit. Circulating fluidized-bed combustion for better air in Berlin; Das Heizkraftwerk Moabit. Zirkulierende Wirbelschichtfeuerung fuer bessere Luft in Berlin

    Energy Technology Data Exchange (ETDEWEB)

    Bade, H.

    1993-08-01

    One main focus of the comprehensive environmental protection programme of the BEWAG (Berliner Kraft- und Licht Aktiengesellschaft) in order to reduce the emissions of the power stations was the modernisation of the combined heating and power station of Moabit. One heating block that had been erected in the middle of the fifties was replaced by a modern plant with the new technique of circulating fluidized bed combustion. The tradition of using the oldest power station of Berlin as a testing field for new directional technologies was carried on. Hence a new power station was erected that did not achieve the reduction of emissions by an additionally connected flue gas dust collector plant but by an environmentally harmless fuel engineering. Since the plant works according to the method of a combined heat and power generation the fuel utilisation is considerably higher than in the case of a pure current generation. The 100-MW heating and power station block with the circulating fluidized bed combustion is the largest plant of this kind in Germany at the present. (orig./KO). [Deutsch] Ein Schwerpunkt des umfassenden Umweltschutzprogrammes der BEWAG zur Senkung der Emissionen der Kraftwerke war die Modernisierung des Heizkraftwerkes Moabit. Als Ersatz fuer einen aus der Mitte der fuenfziger Jahre stammenden Block wurde hier mit der neuen Technik der zirkulierenden Wirbelschichtfeuerung (ZWS) eine moderne Anlage errichtet. Der Tradition des aeltesten Kraftwerkes Berlins als Versuchsfeld fuer neue richtungsweisende Techniken folgend entstand ein Kraftwerk, in dem die Emissionsreduzierung nicht durch nachgeschaltete Rauchgasreinigungsanlagen, sondern durch eine besonders umweltschonende Feuerungstechnik erreicht wurde. Da die Anlage nach dem Prinzip der Kraft-Waerme-Kopplung arbeitet, ist auch die Brennstoffausnutzung bedeutend hoeher als bei reiner Stromerzeugung. Der 100-MW-Heizkraftwerksblock mit ZWS-Feuerung ist die gegenwaertig groesste Anlage dieser Art in

  6. Near IR photometry of the old open clusters Berkeley 17 and Berkeley 18 Probing the age of the galactic disc

    CERN Document Server

    Carraro, G; Girardi, L; Richichi, A; Carraro, Giovanni; Vallenari, Antonella; Girardi, Leo; Richichi, Andrea

    1998-01-01

    We report on near IR ($J$ and $K$ bands) observations of two $8 \\times 8 Berkeley~18, for which only optical photometry (in $B$,$V$ and $I$ bands) exists. $J$ and $K$ photometry allows us to obtain an independent estimate of cluster metallicity by means of the relationship between the spectroscopic metallicity and the Red Giant Branch (RGB) slope calibrated by Tiede et al (1997). From the analysis of the colour magnitude diagram (CMD) and luminosity function (LF), Berkeley~17 turns out to have a metal content $[Fe/H]~\\sim~-0.35$. It is $9~Gyr$ old, suffers from a reddening $E(B-V) = 0.58 mag$ and has an heliocentric distance of $2.5 kpc$. Berkeley~17 comes out to be substantially younger than in previous work (age $\\approx 13~Gyr$). On the other hand Berkeley~18 is found to have solar metal abundance, and to be younger than Berkeley~17, with an age of about $4~Gyr$. While we confirm Kaluzny (1997) reddening estimate, we significantly revise the distance of the cluster, which lies $4.5 kpc$ from the Sun. These...

  7. Woody biomass-based bioenergy development at the Atikokan Power Generating Station: Local perceptions and public opinions

    Science.gov (United States)

    Baten, Cassia Sanzida

    To tackle climate change, reduce air pollution and promote development of renewable energy, the Ontario government is investing in the conversion of the coal-based Atikokan Power Generating Station (APGS) in Atikokan, Ontario, to woody biomass feedstock. This research offers one of the first looks at the perspectives of different individuals and groups on converting woody biomass to energy. Using a combination of study instruments which include literature review, surveys, interviews with key informants, semi-structured interviews, and focus group discussions, this dissertation uses qualitative research to provide a picture of the public's opinions and attitudes towards the APGS biomass energy development. Given Ontario's huge and sustainably managed forest resource, woody biomass is expected to be a major component of renewable energy production in Ontario. The move towards renewable energy that replaces fossil fuels with woody biomass will have considerable socio-economic implications for local and First Nation communities living in and around the bioenergy power generating station. Findings indicate that there is wide support for biomass utilization at the APGS by local people, especially since the project would create sustainable employment. The connection of woody biomass-based energy generation and rural community development provides opportunities and challenges for Atikokan's economic development. Respondents identified economic, environmental and social barriers to biomass utilization, and emphasized trust and transparency as key elements in the successful implementation of the APGS project. As demand for woody biomass-based energy increases, special attention will be needed to ensure and maintain the social, economic and environmental sustainability of biomass use at the APGS. In this research, respondents' views about biomass utilization for energy mainly focused on forest-related issues rather than energy. In Atikokan much of the project's social

  8. The pollution intensity of Australian power stations: a case study of the value of the National Pollutant Inventory (NPI).

    Science.gov (United States)

    Tang, Minmeng; Mudd, Gavin M

    2015-12-01

    This paper presents a comprehensive analysis of the pollutant emissions from electrical generation facilities reported to Australia's National Pollutant Inventory (NPI). The data, in terms of pollutant intensity with respect to generation capacity and fuel source, show significant variability. Based on reported data, the dominant pathway and environmental segment for emissions is point-source air emissions. Surprisingly, pollutant emissions from power stations are generally a very small fraction of Australia's facility and diffuse emissions, except for F, HCl, NO(x), PM2.5, SO2 and H2SO4 (where it constitutes between 30 and 90% of emissions). In general, natural gas and diesel facilities have higher organic pollutant intensities, while black and brown coal have higher metal/metalloid pollutant intensities and there is a wide variability for inorganic pollutant intensities. When examining pollutant intensities with respect to capacity, there is very little evidence to show that increased scale leads to more efficient operation or lower pollutant intensity. Another important finding is that the pollutant loads associated with transfers and reuse are substantial, and often represent most of the reported pollutants from a given generation facility. Finally, given the issues identified with the NPI data and its use, some possible improvements include the following: (i) linking site generation data to NPI data (especially generation data, i.e., MWh); (ii) better validation and documentation of emissions factors, especially the methods used to derive and report estimates to the NPI; (iii) using NPI data to undertake comparative life cycle impact assessment studies of different power stations and fuel/energy sources, or even intensive industrial regions (especially from a toxicity perspective) and (iv) linking NPI data in a given region to ongoing environmental monitoring, so that loads can be linked to concentrations for particular pollutants and the relevant guidelines

  9. Technology, safety and costs of decommissioning a reference boiling water reactor power station. Volume 1. Main report. Technical report, September 1977-October 1979

    Energy Technology Data Exchange (ETDEWEB)

    Oak, H.D.; Holter, G.M.; Kennedy, W.E. Jr.; Konzek, G.J.

    1980-06-01

    Technology, safety and cost information is given for the conceptual decommissioning of a large (1100MWe) boiling water reactor (BWR) power station. Three approaches to decommissioning, immediate dismantlement, safe storage with deferred dismantlement and entombment, were studied to obtain comparisons between costs, occupational radiation doses, potential dose to the public and other safety impacts. It also shows the sensitivity of decommissioning safety and costs to the power rating of a BWR in the range of 200 to 1100 MWE.

  10. A novel static frequency converter based on multilevel cascaded H-bridge used for the startup of synchronous motor in pumped-storage power station

    Energy Technology Data Exchange (ETDEWEB)

    Wang Feng, E-mail: sjtuwfeng@hotmail.co [Key Lab of Control of Power Transmission and Transformation, Ministry of Education, Department of Electrical Engineering, Shanghai Jiaotong University, Minhang District, Shanghai 200240 (China); Jiang Jianguo, E-mail: jiang@sjtu.edu.c [Key Lab of Control of Power Transmission and Transformation, Ministry of Education, Department of Electrical Engineering, Shanghai Jiaotong University, Minhang District, Shanghai 200240 (China)

    2011-05-15

    Research highlights: {yields} A novel Static Frequency Converter (SFC) based on multilevel cascaded H-bridge (CHB) topology is proposed and used for the reversible pump-generating units in pumped-storage power station. {yields} The novel SFC based on CHB has compact configuration, low current harmonic distortion and fast speed response. {yields} Rotor position and Grid connection are realized successfully by the novel SFC. -- Abstract: A novel static frequency converter (SFC) is proposed and is used firstly to start the reversible pump-generating units in pumped-storage power station. Multilevel cascaded H-bridge (CHB) topology and Insulated Gate Bipolar Transistor (IGBT) are applied in the novel SFC. In comparison with the conventional SFC adopting load-commutated inverter (LCI) which is composed of silicon-controlled rectifier (SCR), the novel one has plenty of advantages such as compact configuration, low current harmonic distortion and fast speed response, and these advantages have been verified during 2-year operation at Xiang Hong Dian Pumped-storage power station in China. This application shows that the novel SFC greatly enhances the reliability and success rate of connecting to grid for starting up the pump-generating units. The principle, characteristic and performance of the novel SFC are described in this paper, and some key issues related to the startup of the units of the pumped-storage power station are also presented.

  11. Mercury concentrations in water resources potentially impacted by coal-fired power stations and artisanal gold mining in Mpumalanga, South Africa

    CSIR Research Space (South Africa)

    Williams

    2010-09-01

    Full Text Available impacted by major anthropogenic mercury (Hg) sources (i.e coal-fired power stations and artisanal gold mining activities). Aqueous TotHg concentrations were found to be elevated above the global average (5.0 ng/L) in 38% of all aqueous samples, while...

  12. [Experience in organization of joint actions of expert divisions during the accident at P.S. Podporozniy Sayano-Shushenskaya hydroelectric power station].

    Science.gov (United States)

    Kolkutin, V V; Ivanov, P L; Fetisov, V A; Afanas'ev, S A; Dorozhkin, O A; Vognerubov, R N; Kuznetsov, T L

    2010-01-01

    The authors illustrate positive experience in organization and coordination of joint actions of expert divisions of different sectors during the accident at P.S. Podporozniy Sayano-Shushenskaya hydroelectric power station in August 2009. Special emphasis is laid on the participation of experts of quick-reaction teams formed by territorial forensic medical bureaus, mobile and supporting forces from the adjacent regions.

  13. Application of positive matrix factorization, multi-linear engine and back trajectory techniques to the quantification of coal-fired power station pollution in metropolitan Sydney

    Science.gov (United States)

    Cohen, David D.; Crawford, Jagoda; Stelcer, Eduard; Atanacio, Armand J.

    2012-12-01

    Over 900 fine particle Teflon filters were collected within the Sydney Basin between 1 January 2001 and 31 December 2011 and analyzed using simultaneous PIXE, PIGE, RBS and PESA techniques to determine 21 different elements between hydrogen and lead. These elements were used in positive matrix factorization (PMF) and multi-linear engine (ME) techniques together with HYSPLIT wind back trajectory techniques to quantitatively determine source fingerprints and their contributions from coal-fired power stations. The power stations were many kilometers outside the greater Sydney metropolitan area but still had a significant impact on the fine particle mass loadings measured at the sampling site within this metropolitan area. The PM2.5 eleven year average mass at the sampling site was 6.48 μg m-3. The corresponding ammonium sulfate estimate was 1.65 μg m-3 or 26% of the PM2.5 mass. By applying back trajectory data and (ME) analysis methods, two power related fingerprints, secondary sulfate (2ndrySPower) and aged industrial sulfur (IndSagedPower) were determined. These two power related fingerprints were responsible for between 14 and 18% of the total PM2.5 mass and 34-47% of the total sulfate measured at the sampling site. That is on average somewhere between a third and a half of all the sulfate measured in the greater Sydney region could be attributed to coal-fired power station emissions.

  14. Improved sampling and analytical techniques for characterization of very-low-level radwaste materials from commercial nuclear power stations

    Energy Technology Data Exchange (ETDEWEB)

    Robertson, D.E. [Pacific Northwest Labs., Richland, WA (United States); Robinson, P.J. [Electric Power Research Inst., Palo Alto, CA (United States)

    1989-11-01

    This paper summarizes the unique sampling methods that were utilized in a recently completed project sponsored by the Electric Power Research Institute (EPRI) to perform accurate and precise radiological characterizations of several very-low-level radwaste materials from commercial nuclear power stations. The waste types characterized during this project included dry active waste (DAW), oil, secondary-side ion exchange resin, and soil. Special precautions were taken to insure representative sampling of the DAW. This involved the initial direct, quantitative gamma spectrometric analyses of bulk quantities (208-liter drums) of DAW utilizing a specially constructed barrel scanner employing a collimated intrinsic germanium detector assembly. Subsamples of the DAW for destructive radiochemical analyses of the difficult-to-measure 10CF61 radionuclides were then selected which had the same isotopic composition (to within {+-}25%) as that measured for the entire drum of DAW. The techniques for accomplishing this sampling are described. Oil samples were collected from the top, middle and bottom sections of 208-liter drums for radiochemical analyses. These samples were composited to represent the entire drum of oil. The accuracy of this type of sampling was evaluated by comparisons with direct, quantitative assays of a number of the drums using the barrel scanning gamma-ray spectrometer. The accuracy of sampling drums of spent secondary-side ion exchange resin was evaluated by comparing the radionuclide contents of grab samples taken from the tops of the drums with direct assays performed with the barrel scanner. The results of these sampling evaluations indicated that the sampling methods used were generally adequate for providing a reasonably representative subsample from bulk quantities of DAW, oil, and resin. The study also identified a number of potential pitfalls, in sampling of these materials.

  15. Improved sampling and analytical techniques for characterization of very-low-level radwaste materials from commercial nuclear power stations

    Energy Technology Data Exchange (ETDEWEB)

    Robertson, D.E. [Pacific Northwest Labs., Richland, WA (United States); Robinson, P.J. [Electric Power Research Inst., Palo Alto, CA (United States)

    1989-11-01

    This paper summarizes the unique sampling methods that were utilized in a recently completed project sponsored by the Electric Power Research Institute (EPRI) to perform accurate and precise radiological characterizations of several very-low-level radwaste materials from commercial nuclear power stations. The waste types characterized during this project included dry active waste (DAW), oil, secondary-side ion exchange resin, and soil. Special precautions were taken to insure representative sampling of the DAW. This involved the initial direct, quantitative gamma spectrometric analyses of bulk quantities (208-liter drums) of DAW utilizing a specially constructed barrel scanner employing a collimated intrinsic germanium detector assembly. Subsamples of the DAW for destructive radiochemical analyses of the difficult-to-measure 10CF61 radionuclides were then selected which had the same isotopic composition (to within {+-}25%) as that measured for the entire drum of DAW. The techniques for accomplishing this sampling are described. Oil samples were collected from the top, middle and bottom sections of 208-liter drums for radiochemical analyses. These samples were composited to represent the entire drum of oil. The accuracy of this type of sampling was evaluated by comparisons with direct, quantitative assays of a number of the drums using the barrel scanning gamma-ray spectrometer. The accuracy of sampling drums of spent secondary-side ion exchange resin was evaluated by comparing the radionuclide contents of grab samples taken from the tops of the drums with direct assays performed with the barrel scanner. The results of these sampling evaluations indicated that the sampling methods used were generally adequate for providing a reasonably representative subsample from bulk quantities of DAW, oil, and resin. The study also identified a number of potential pitfalls, in sampling of these materials.

  16. Effect of water chemistry upsets on the dynamics of corrective reagent dosing systems at thermal power stations

    Science.gov (United States)

    Voronov, V. N.; Yegoshina, O. V.; Bolshakova, N. A.; Yarovoi, V. O.; Latt, Aie Min

    2016-12-01

    Typical disturbances in the dynamics of a corrective reagent dosing system under unsteady-state conditions during the unsatisfactory operation of a chemical control system with some water chemistry upsets at thermal and nuclear power stations are considered. An experimental setup representing a physical model for the water chemistry control system is described. The two disturbances, which are most frequently encountered in water chemistry control practice, such as a breakdown or shutdown of temperature compensation during pH measurement and an increase in the heat-transfer fluid flow rate, have been modeled in the process of study. The study of the effect produced by the response characteristics of chemical control analyzers on the operation of a reagent dosing system under unsteady-state conditions is important for the operative control of a water chemistry regime state. The effect of temperature compensation during pH measurement on the dynamics of an ammonia-dosing system in the manual and automatic cycle chemistry control modes has been studied. It has been demonstrated that the reading settling time of a pH meter in the manual ammonia- dosing mode grows with a breakdown in temperature compensation and a simultaneous increase in the temperature of a heat-transfer fluid sample. To improve the efficiency of water chemistry control, some systems for the quality control of a heat-transfer fluid by a chemical parameter with the obligatory compensation of a disturbance in its flow rate have been proposed for use. Experimental results will possibly differ from industrial data due to a great length of sampling lines. For this reason, corrective reagent dosing systems must be adapted to the conditions of a certain power-generating unit in the process of their implementation.

  17. The accident at TEPCO's Fukushima-Daiichi Nuclear Power Station: What went wrong and what lessons are universal?

    Science.gov (United States)

    Omoto, Akira

    2013-12-01

    After a short summary of the nuclear accident at the Fukushima Daiichi Nuclear Power Station, this paper discusses “what went wrong” by illustrating the problems of the specific layers of defense-in-depth (basic strategy for assuring nuclear safety) and “what lessons are universal.” Breaches in the multiple layers of defense were particularly significant in respective protection (a) against natural disasters (first layer of defense) as well as (b) against severe conditions, specifically in this case, a complete loss of AC/DC power and isolation from the primary heat sink (fourth layer of defense). Confusion in crisis management by the government and insufficient implementation of offsite emergency plans revealed problems in the fifth layer of defense. By taking into consideration managerial and safety culture that might have relevance to this accident, in the author's view, universal lessons are as follows: Resilience: the need to enhance organizational capabilities to respond, monitor, anticipate, and learn in changing conditions, especially to prepare for the unexpected. This includes increasing distance to cliff edge by knowing where it exists and how to increase safety margin. Responsibility: the operator is primarily responsible for safety, and the government is responsible for protecting public health and environment. For both, their right decisions are supported by competence, knowledge, and an understanding of the technology, as well as humble attitudes toward the limitations of what we know and what we can learn from others. Social license to operate: the need to avoid, as much as possible regardless of its probability of occurrence, the reasonably anticipated environmental impact (such as land contamination), as well as to build public confidence/trust and a renewed liability scheme.

  18. 基于双层 BP 神经网络的光伏电站输出功率预测%Photovoltaic power station output power prediction based on the double BP neural network

    Institute of Scientific and Technical Information of China (English)

    张立影; 孟令甲; 王泽忠

    2015-01-01

    光伏电站输出功率对电网调度有很大影响,但受到太阳辐射强度和气象因素的影响,光伏电站输出功率具有随机性和不可控性。为合理利用光伏发电系统,建立一种基于气象预测信息以及BP神经网络的光伏电站输出功率预测模型。通过相关性分析确定影响光伏出力的影响因子,结合历史数据和气象因素进行模型训练和功率预测。文中主要提出一种新的预测模型-双层BP神经网络模型,通过对某光伏电站预测结果与实测值对比,结果表明该方法能有效提高光伏电站输出功率预测精度,对发电计划的制定有较好的参考价值和实用价值。%Photovoltaic power station output power has a great influence on power grid dispatching , but the photovolta-ic power station output power is random and uncontrollable due to the intensity of solar radiation and meteorological factors.In order to make reasonable use of the photovoltaic power generation system , a photovoltaic power station out-put power model based on weather forecast information and the BP neural network was proposed in the paper .The in-fluential factors of PV station output power were determined through correlation analysis .The model training and power prediction were processed by combination with historical data and meteorological factors .A new forecasting model , the double BP neural network model , was proposed in this paper .The predicted results of a photovoltaic power station were compared with the measured values .The results showed that the method could effectively improve the predictive accuracy of the PV station output power and had good reference values and practical values to power generation plan -ning.

  19. Intra- and inter-unit variation in fly ash petrography and mercury adsorption: Examples from a western Kentucky power station

    Science.gov (United States)

    Hower, J.C.; Finkelman, R.B.; Rathbone, R.F.; Goodman, J.

    2000-01-01

    Fly ash was collected from eight mechanical and 10 baghouse hoppers at each of the twin 150-MW wall-fired units in a western Kentucky power station. The fuel burned at that time was a blend of many low-sulfur, high-volatile bituminous Central Appalachian coals. The baghouse ash showed less variation between units than the mechanical hoppers. The mechanical fly ash, coarser than the baghouse ash, showed significant differences in the amount of total carbon and in the ratio of isotropic coke to both total carbon and total coke - the latter excluding inertinite and other unburned, uncoked coal. There was no significant variation in proportions of inorganic fly ash constituents. The inter-unit differences in the amount and forms of mechanical fly ash carbon appear to be related to differences in pulverizer efficiency, leading to greater amounts of coarse coal, therefore unburned carbon, in one of the units. Mercury capture is a function of both the total carbon content and the gas temperature at the point of fly ash separation, mercury content increasing with an increase in carbon for a specific collection system. Mercury adsorption on fly ash carbon increases at lower flue-gas temperatures. Baghouse fly ash, collected at a lower temperature than the higher-carbon mechanically separated fly ash, contains a significantly greater amount of Hg.

  20. Effect of phase and size characteristics of fly ash from power station on properties of bitumen composites

    Science.gov (United States)

    Lebedev, M. S.; Kozhukhova, N. I.; Chulkova, I. L.

    2017-07-01

    Fly ash from power stations is one of the effective fillers in bitumen binders due to its high specific surface area in origin state. This paper is focused on study of effect of phase and size characteristics of fly ashes on properties of bitumen binder. In this work a high-calcium (FA1) and low-calcium (FA2) fly ashes are used. According to chemical and mineral composition of FA1 is reactive in water medium because it contains hydraulic minerals. FA2 is hydraulically inert mainly consisting of aluminosilicate vitreous phase. FA1 is characterized by higher specific surface vs. FA2 according to Blain method data but lower specific surface measured with BET method. It can be associated with high porosity of FA2 that significantly influent on bitumen content in binding system. Lower packing density of FA2 particles leads to reducing of strength characteristics in bitumen composite. Low adsorption of bitumen to surface of FA1 particles initiates hydration process of reactive minerals as well as formation of ettringite phase that leads to extension of the binder system and structure decompaction. Bitumen composites based on FA2 with higher adsorptive capacity is characterized by more stable structure.