WorldWideScience

Sample records for bepc ii positron

  1. BEPC II positron source

    International Nuclear Information System (INIS)

    Pei Guoxi; Sun Yaolin; Liu Jintong; Chi Yunlong; Liu Yucheng; Liu Nianzong

    2006-01-01

    BEPC II-an upgrade project of the Beijing Electron Positron Collider (BEPC) is a factory type of e + e - collider. The fundamental requirements for its injector linac are the beam energy of 1.89 GeV for on-energy injection and a 40 mA positron beam current at the linac end with a low beam emittance of 1.6 μm and a low energy spread of ±0.5% so as to guarantee a higher injection rate (≥50 mA/min) to the storage ring. Since the positron flux is proportional to the primary electron beam power on the target, the authors will increase the electron gun current from 4A to 10A by using a new electron gun system and increase the primary electron energy from 120 MeV to 240 MeV. The positron source itself is an extremely important system for producing more positrons, including a positron converter target chamber, a 12kA flux modulator, the 7m focusing module with DC power supplies and the support. The new positron production linac from the electron gun to the positron source has been installed into the tunnel. In what follows, the authors will emphasize the positron source design, manufacture and tests. (authors)

  2. Energy determination at BEPC-II

    International Nuclear Information System (INIS)

    Achasov, M.N.; Blinov, V.E.; Bogomyagkov, A.V.; Fu ChengDong; Harris, F.A.; Kaminsky, V.V.; Liu, Q.; Mo Xiaohu; Muchnoi, N.Yu.; Nikitin, S.A.; Nikolaev, I.B.; Qin Qing; Qu Huamin; Olsen, S.L.; Pyata, E.E.; Shamov, A.G.; Shen, C.P.; Varner, G.S.; Wang Yifang; Xu Jinqiang

    2009-01-01

    The BEPC-II collider beam energy calibration system is discussed. The system is based on the Compton backscattering method. The expected precision of the electron and positron beam energy ε determination is δε/ε∼3.10 -5 .

  3. Simulation of the electron cloud density in BEPC II

    International Nuclear Information System (INIS)

    Liu Yudong; Guo Zhiyuan; Wang Jiuqing

    2004-01-01

    Electron Cloud Instability (ECI) may take place in positron storage ring when the machine is operated with multi-bunch positron beam. According to the actual shape of the vacuum chamber in the BEPC II, a program has been developed. With the code, authors can calculate the electron density in the chamber with different length of antechamber and the different secondary electron yield respectively. By the simulation, the possibility to put clearing electrodes in the chamber to reduce the electron density in the central region of the chamber is investigated. The simulation provides meaningful and important results for the BEPC II project and electron cloud instability research

  4. Design and field measurement of the BEPC-II interaction region dual-aperture quadrupoles

    International Nuclear Information System (INIS)

    Yin, Z.S.; Wu, Y.Z.; Zhang, J.F.; Chen, W.; Li, Y.J.; Li, L.; Hou, R.; Yin, B.G.; Sun, X.J.; Ren, F.L.; Wang, F.A.; Chen, F.S.; Yu, C.H.; Chen, C.

    2007-01-01

    With the Beijing Electron Positron Collider upgrade project (BEPC-II), two dual-aperture septum-style quadrupole magnets are used in the interaction region for the final focusing of the electron and positron beams. The BEPC-II lattice design calls for the same high quality integral quadrupole field and large good field region in both apertures for each magnet. Two-dimensional contour optimization and pole-end chamfer iteration are used to minimize the systematic harmonic errors. Unexpected non-systematic errors induced by the unsymmetrical structure and the manufacturing errors are compensated with the pole-end shimming. Magnet measurements with rotating coils are performed to guide and confirm the magnet design. This paper discusses the design consideration, optimizing procedure and measurement results of these dual-aperture magnets

  5. Logic of quench protection assembly for BEPC II interaction region superconducting magnet

    International Nuclear Information System (INIS)

    Chen Fusan; Cheng Jian

    2006-01-01

    Two superconducting magnet complexes are used in BEPC II interaction region. The corresponding quench protection system divides all related faults into two classes and takes different protection actions according to the urgency degree. Since BEPC II has two operating modes and the superconducting magnets use different power supplies in different operating modes, the quench protection system must take the mode switching into consideration. (authors)

  6. J/psi physics at BEPC

    International Nuclear Information System (INIS)

    Chanowitz, M.S.

    1984-06-01

    J/psi physics is discussed which will be of interest at T > 1988, the period of operation of the Beijing Electron Positron Collider. Emphasis is placed on the gluonic states which are best studied in radiative J/psi decay. The difficulties of these studies are discussed and the need for very high statistics is stressed. In particular it is essential to partial-wave-analyze the hadronic final states produced in J/psi → γX. An estimate using fixed target data suggests that 0(10 8 ) J/psi decays are needed to do an unambiguous partial wave analysis for hadron masses up to about 2 GeV. This requirement is an excellent match to the BEPC design parameters, which imply production of 0(10 8 ) J/psi's per year. With a J/psi production rate an order of magnitude greater than other electron-positron storage rings, BEPC will be a unique world facility for these studies. 58 references

  7. Committee Report of the BEPC-II Project Design Review May 13-15, 2002, SLAC

    Energy Technology Data Exchange (ETDEWEB)

    Kawakami, Traci M.

    2002-08-26

    As part of the US-China Cooperative Program in High Energy Physics for the year 2002, a BEPC-II Upgrade Review meeting was held at SLAC, May 13-15, 2002. The upgrade is aimed at improving the luminosity and performance of the BEPC facility at IHEP in Beijing, China with major upgrades to the injector linac, storage ring, and detector. This review addresses mainly the accelerator related issues. Prior to the review, an updated Draft Design Report was made available to the review team. Most important technical change since April 2001 has been a change from a single-ring configuration to a doublering. The goal of the review is to determine whether BEPC-II, if built as described, will meet the operations and physics goals. The charge to the review team is attached as Appendix A.

  8. Status report of BEPC and BES

    International Nuclear Information System (INIS)

    Zheng Zhipeng; Qi Nading

    1990-01-01

    A new era in China's scientific history started in October 1988, when the nation became a new member of high energy e + e - collider club. On 16th and 23rd of that month, the first e + e - collision at 1.6 Gev for each beam with peak luminosity of 4 x 10 27 cm -2 s -1 was realized in BEPC (Beijing Electron Positron Collider) and the first graphic display of cosmic ray was obtained by BES (Beijing Spectrometer). Now, the BES sits at the intersection point of the BEPC and is collecting data. BEPC is composed of a 202 m long LANAC (electron preinjector; positron generator; main accelerator of 1.5 GeV) and SR (storage ring) of circumference of 240 meter with 2 intersection points. The BES is a general purpose magnetic spectrometer, which is designed to provide particle identification and energy measurement. The main parts of the BES described here include the beam pipe of thin aluminum, CDC (central drift chamber), MDC (main drift chamber), time-of-flight counter, shower counter, solenoid magnet, muon counter, luminosity monitor, readout electronics, on-line data acquisition, trigger, and off-line data analysis system. Synchrotron radiation facilities are now being built. (N.K.)

  9. New BEPC interlock system

    International Nuclear Information System (INIS)

    Tang Shuming; Na Xiangyin; Chen Jiansong; Yu Yulan; Cai Guangyu; Wu Jingmin; Li Tiehui

    1998-01-01

    A new interlock system for BEPC (Beijing Electron Positron Collider) has been developed in order to improve the reliability of the personal safety and the subsystem's interlocks. Another role of the system is to update the BEPC TV status screen once every 6 seconds. The hardware for the new interlock system is based on industrial Programmable logic controllers (PLC). By means of the PC-links, the interlock system is composed as a distributed control system. One inexpensive multimedia IBM/486 PC is used as the host computer of the PLCs. The application programs dedicated for the system is written in visual C++ language under Chinese MS-Windows. In case there is a failure in a subsystem, the message is displayed visually, supplemented by a voice message, which causes the operators to pay attention

  10. Application software for new BEPC interlock system

    International Nuclear Information System (INIS)

    Tang Shuming; Na Xiangyin; Chen Jiansong; Yu Yulan

    1997-01-01

    New BEPC (Beijing electron Positron collider) interlock system has been built in order to improve the reliability of personnel safety and interlock functions. Moreover, the system updates BEPC operation message once every 6 seconds, which are displayed on TV screens at the major entrances. Since March of 1996, new BEPC interlock system has been operating reliably. The hardware of the system is based on Programmable Logic Controllers (PLC). A multimedia IBM/PC-586 as the host computer of the PLCs, monitors the PLC system via serial port COM2. The PC communicates with the central computer VAX-4500 of BEPC control system and gets operating massage of the accelerator through serial port COM3. The application software on the host computer has been developed. Visual C++ for MS-Windows 3.2 TM is selected as the work bench. It provides nice tools for building programs, such as APP STUDIO, CLASS WIZARD, APP WIZARD and debugger tool. The author describes the design idea and the structure of the application software. Error tolerance is taken into consideration. The author also presents a small database and its data structure for the application

  11. The beam energy measurement system for the Beijing electron-positron collider

    International Nuclear Information System (INIS)

    Zhang, J.Y.; Abakumova, E.V.; Achasov, M.N.; Blinov, V.E.; Cai, X.; Dong, H.Y.; Fu, C.D.; Harris, F.A.; Kaminsky, V.V.; Krasnov, A.A.; Liu, Q.; Mo, X.H.; Muchnoi, N.Yu.; Nikolaev, I.B.; Qin, Q.; Qu, H.M.; Olsen, S.L.; Pyata, E.E.; Shamov, A.G.; Shen, C.P.

    2012-01-01

    The beam energy measurement system (BEMS) for the upgraded Beijing electron-positron collider BEPC-II is described. The system is based on measuring the energies of Compton back-scattered photons. The relative systematic uncertainty of the electron and positron beam energy determination is estimated as 2⋅10 -5 .

  12. A study on the front-end VME system of BEPC II

    International Nuclear Information System (INIS)

    Wang Chunhong

    2004-01-01

    The front-end VME system is not only the heart of the control system, but also a real-time system. This paper describes the component of the front-end VME (Versa Module Eurocard) system including control computer and some related I/O modules. Particularly, the authors present a best solution for the problems about Vx-Works kernel and BSP running on MVME5100. This is a fundamental setup of the BEPC II control system. (author)

  13. The beam energy measurement system for the Beijing electron-positron collider

    International Nuclear Information System (INIS)

    Abakumova, E.V.; Achasov, M.N.; Blinov, V.E.; Cai, X.; Dong, H.Y.; Fu, C.D.; Harris, F.A.; Kaminsky, V.V.; Krasnov, A.A.; Liu, Q.; Mo, X.H.; Muchnoi, N.Yu.; Nikolaev, I.B.; Qin, Q.; Qu, H.M.; Olsen, S.L.; Pyata, E.E.; Shamov, A.G.; Shen, C.P.; Todyshev, K.Yu.

    2011-01-01

    The beam energy measurement system (BEMS) for the upgraded Beijing electron-positron collider BEPC-II is described. The system is based on measuring the energies of Compton back-scattered photons. The relative systematic uncertainty of the electron and positron beam energy determination is estimated as 2×10 -5 . The relative uncertainty of the beam's energy spread is about 6%.

  14. Optimization studies on BEPC II future pre-injector with two SHBs

    International Nuclear Information System (INIS)

    Pei Shilun; Wang Shuhong; Gu Pengda; Liu Bo

    2004-01-01

    The BEPC II future pre-injector consists of a thermionic gun followed by two subharmonic bunchers (SHB), a travelling wave prebuncher and a travelling wave buncher. All components downstream of the gun are immersed in a solenoid field for transverse focusing. Beam dynamics simulation and optimization have been carried out with programs PARMELA and EGUN. SHBs' bunching voltage and bunching drift distance, prebuncher and buncher's phase and acceleration gradient, and solenoid field profile have been studied. The bunch charge limitation for 10 ps bunch length at the buncher exit is also investigated

  15. A test beam upgrade based on the BEPC-LINAC

    International Nuclear Information System (INIS)

    Li Jiacai; Wu Yuanming; Cui Xiangzong; Zhang Liangsheng; Zhou Baoqing; Liu Zhengquan; Zhang Shaoping; Sun Changchun; Zhang Zhuxiang; Zhang Caidi; Zheng Linsheng; Liu Shixing; Shen Ji; Yin Zejie; Zhang Yongming; Chen Ziyu

    2004-01-01

    A total of three beam lines, E1, E2 and E3 have based on the LINAC of BEPC. The E1 beam is to be used for intense slow-positron facility. The E2 is a primary positron or electron beam with an energy of 1.3-1.5 GeV. The E3 is a secondary electron or pion test beam with a momentum can be adjustable continuously. The position accuracy of a detected particle is 0.2-0.4 mm with an event rate of 3 - 4 Hz. This beam has been successfully used for some detectors beam test. (author)

  16. Transverse blowup along bunch train caused by electron cloud in BEPC

    International Nuclear Information System (INIS)

    Liu Yudong; Guo Zhiyuan; Qin Qing; Wang Jiuqing; Zhao Zheng

    2006-01-01

    Electron cloud instability (ECI) may take place in a storage ring when the machine is operated with a multi-bunch positively charged beam. Transverse blowup due to electron cloud has been observed in some machines and is considered to be a major limit factor in the development of high current and high luminosity electron positron colliders. With a streak camera, the transverse blowup along the bunch train was first observed in an experiment at the Beijing Electron-Positron Collider (BEPC) and the simulation results were used to compared with the observation. (authors)

  17. [Commissioning of the newly constructed Beijing electron-positron collider BEPC, Beijing, China, and visit to SRRC to discuss magnet manufacturing and measurement methods, Taipei, Taiwan, November 11--27, 1988]: Foreign trip report

    International Nuclear Information System (INIS)

    Weng, W.T.

    1988-01-01

    The traveller was invited to IHEP to participate in the commissioning of the newly constructed Beijing electron-positron collider BEPC, give a status report on the AGS Booster Project and to assess the feasibility of sub-contracting booster sextupoles to IHEP. The trip to SRRC was undertaken to discuss magnet manufacturing and measurement methods

  18. Status of the BEPC control system

    International Nuclear Information System (INIS)

    Zhao Jijiu; Yan Yonghe; Zhan Mingchuan; Yu Yulan; Luo Huiying; Wang Yaru; Geng Xiaosong

    1994-01-01

    The control system of the Beijing Electron Positron Collider (BEPC) was built by the end of 1987. Since then, it has been running safely and reliably. Due to the tight construction schedule, we adopted the control system structure of the new SPEAR of SLAC, which was a centralized control system. The system was not performing very well due to various problems such as low CPU power, limited memory of the VAX-11/750 control computer, a bottle-neck of the VAX-CAMAC-Channel etc. Since 1991 we have therefore been working on upgrading it to a distributed control system based on DECnet. The old console will be replaced by VAX-4090 workstations. The status of the system and the progress of the upgrading work are presented in this paper. ((orig.))

  19. Development of rapid detection system on BEPC Ⅱ magnet power supply

    International Nuclear Information System (INIS)

    Chen Suying; Zhan Mingchuan; Long Fengli; Ye Weidong

    2014-01-01

    To quickly find the causes of the accelerator unstable or lost beam caused by magnet power supply in Beijing Electron Positron Collider (BEPC Ⅱ) running, the rapid detection system for magnet power supply was developed. The stability of the system in 8 h is about 0.005%, and it can acquire over nearly 500 sets of magnet power supply current values most quickly in 0.33 ms. All data were written to the MySQL database in real time, so as to be able to quickly troubleshoot magnet power supply problem through historical data analysis and comparison. (authors)

  20. Two-pulse acceleration for BEPCII injector linac

    International Nuclear Information System (INIS)

    Pei Shilun; Wang Shuhong; Lu Weibin

    2007-01-01

    In order to double the injection rate of positron beam from the linac to the storage ring of BEPC II, a two-pulse generation and acceleration scheme has been proposed. The two-pulse simulation by programs including LIAR, PARMELA, EGUN and TRANSPORT is described first and the method is applied in the beam dynamics studies of BEPC II linac. The experiment of two-pulse acceleration was performed in BEPC II linac and some preliminary results are obtained, which provides a good reference for further upgrading of BEPC II injector linac. (authors)

  1. Upgrading the BEPC control system

    International Nuclear Information System (INIS)

    Yang Liping; Wang Lizheng; Liu Shiyao

    1992-01-01

    The BEPC control system has been put into operation and operated normally since the end of 1987. Three years's experience shows this system can satisfy basically the operation requirements, also exhibits some disadvantages araised from the original centralized system architecture based on the VAX-VCC-CAMAC, such as slow response, bottle neck of VCC, less CPU power for control etc.. This paper describes the method and procedure for upgrading the BEPC control system which will be based on DEC net and DEC-WS, and thus intend to upgrade the control system architecture from the centralized to the distributed and improve the integral system performance. (author)

  2. On the average luminosity of electron positron collider and positron-producing energy

    International Nuclear Information System (INIS)

    Xie Jialin

    1985-01-01

    In this paper, the average luminosity of linac injected electron positron collider is investigated from the positron-producing energy point of view. When the energy of the linac injector is fixed to be less than the operating energy of the storage ring, it has been found that there exists a positron-producing energy to give optimum average luminosity. Two cases have been studied, one for an ideal storage ring with no single-beam instability and the other for practical storage ring with fast head-tail instability. The result indicates that there is a positron-producing energy corresponding to the minimum injection time, but this does not correspond to the optimum average luminosity for the practical storage rings. For Beijing Electron Positron Collider (BEPC), the positron-producing energy corresponding to the optimum average luminosity is about one tenth of the total injector energy

  3. Application of multiwire proportional chamber in BEPC test beam

    International Nuclear Information System (INIS)

    Shen Ji; Chen Ziyu; Ye Yunxiu; Cuiu Xiangzong; Li Jiacai

    2006-01-01

    This paper describes a Multiwire Proportional Chamber (MWPC) for the Test Beam on BEPC (Beijing Electron Positron Colider). The distance between the anode surface and the cathode surface of the MWPC is 6 mm. Both surfaces are made of gold-plated tungsten wires, the anode wires are 20 μm in diameter and 2 mm apart, and the cathode wires are 50 μm indiameter and 0.7 mm apart. Six adjacent wires are connected together to form a 4.2 mm wide cathode strip. The MWPC can localize the particles of e, π by cathode-induced charge centre-of-gravity read-out. For 5.9 keV γ photon, the positional resolution is less than 0.3 mm (FWHM) and for 1.1 GeV beam electron, 0.224 mm (FWHM) positional resolution is attained. (authors)

  4. Design of BEPCII bunch current monitor system

    International Nuclear Information System (INIS)

    Zhang Lei; Ma Huizhou; Yue Junhui; Lei Ge; Cao Jianshe; Ma Li

    2008-01-01

    BEPC II is an electron-positron collider designed to run under multi-bunches and high beam current condition. The accelerator consists of an electron ring, a positron ring and a linear injector. In order to achieve the target luminosity and implement the equal bunch charge injection, the Bunch Current Monitor (BCM) system is built on BEPC II. The BCM system consists of three parts: the front-end circuit, the bunch current acquisition system and the bucket selection system. The control software of BCM is based on VxWorks and EPICS. With the help of BCM system, the bunch current in each bucket can be monitored in the Central Control Room. The BEPC II timing system can also use the bunch current database to decide which bucket needs to refill to implement 'top-off' injection. (authors)

  5. The network communication of BEPC control system

    International Nuclear Information System (INIS)

    Xu Jingwei

    1997-01-01

    The author introduces the application of network communication of BEPC control system. The authors use non-transparent communication to transfer the data and command information from node VAX750 to VAX4500

  6. MWPC for the test beam on BEPC-LINAC

    International Nuclear Information System (INIS)

    Shen Ji; Chen Ziyu; Ye Zhenyu; Jiang Linli; Pan Jianjun; Ye Yunxiu; Cui Xiangzhong; Li Jiacai

    2004-01-01

    This paper introduces the MWPC developed for the test on BEPC, which localizes the particles of e, π by center of gravity of the signals induced on the cathodes of the chamber, and describes its configuration, structure and the investigation of properties. (authors)

  7. Virtual photon impulse of bunch, beampipe response, coherent RF Beamstrahlung; and BEPC bunch length, BES jam, virtual acceleration

    International Nuclear Information System (INIS)

    Jing Shen

    1993-01-01

    A brief EEE view of signal QED is presented. The research has been concentrated on the virtual photon modes of ultra relativistic shock wave in a bunch-beampipe system, and real photon modes of Coherent RF Beamstrahlung CRFB. Physically, the virtual photons emitted by a bunch were treated as a travelling pseudo wave packet in a flight coaxial cavity constructed by bunch-wakefield core and beampipe. Mathematically, it is a boundary solution of shock wave excited by ultra relativistic impulse of bunch. The new modes of solution: VTA, VTEM, VTM, VLE are virtual photon packets and RTE, RTM, RTEM are real photon modes of CRFB. By these results the author measured and corrected BEPC bunch length from signals of : (1) TOF reference of BES, (2) BPM of BEPC, (3) Colliding CRFB of BEPC - BES coupling signal, as well as (4) the ordinary method of Synchrotron Radiation. All results of the measured bunch lengths are in accordance with the design length of BEPC, and were verified by the BES data of vertex reconstruction of hadron events. The author also found that CRFB is the unknown jam source of BES electronics. VLE virtual photons can accelerate particles

  8. IHEP S-band 45 MW pulse power klystron development

    International Nuclear Information System (INIS)

    Dong Dong; Zhou Zusheng; Zhang Liang; Li Gangying; Tian Shuangmin

    2006-01-01

    S-band 45 MW pulse power klystron has been developed in the Institute of High Energy Physics (IHEP) for the Beijing Electron Positron Collider (BEPC) upgrade projects (BEPC-II). This new klystron has 5 cavities in its RF-beam interaction and single RF output window, and the RF output power is 45 MW at 310 kV, the gain is 50 dB, the efficiency 40%. The manufacturing, training and testing of a prototype klystron has been finished in IHEP and RF power 45 MW at 300 kV has been reached. The testing results show that all the parameters of the 45 MW klystron reach the design goal. (authors)

  9. Solvated Positron Chemistry. II

    DEFF Research Database (Denmark)

    Mogensen, O. E.

    1979-01-01

    The reaction of the hydrated positron, eaq+ with Cl−, Br−, and I− ions in aqueous solutions was studied by means of positron The measured angular correlation curves for [Cl−, e+], [Br−, e+, and [I−, e+] bound states were in good agreement with th Because of this agreement and the fact...... that the calculated positron wavefunctions penetrate far outside the X− ions in the [X−, e+] sta propose that a bubble is formed around the [X−, e+] state, similar to the Ps bubble found in nearly all liquids. F−ions did not react w Preliminary results showed that CN− ions react with eaq+ while OH−ions are non...... in the Cl− case) at higher concentrations. This saturation and the high-concentration effects-in the angular correlation results were interpreted as caused by rather complicated spur effects, wh It is proposed that spur electrons may pick off the positron from the [X−, e+ states with an efficiency which...

  10. BES-II fast data reconstruction

    International Nuclear Information System (INIS)

    Rong Gang; Zhang Jiawen; Guo Yiqing; Zhang Shaoqiang; Zhao Dixin

    2002-01-01

    The BES-II fast data reconstruction is reported. Based on PC FARM and/or a 'Distributed Clustered Linux PC System', BES-II fast data reconstruction system is set up. With this system the BES-II data can be fully reconstructed in about 20 minutes after data collection. It takes only 12 minutes to fully reconstruct 30000 events, collected with BES-II detector at BEPC Collider, with a P III-800 PC. The detector performance can be examined based on fully reconstructed data in about 20 minutes after data taking in the BES-II experiment

  11. PRC/US collaboration in SSC construction

    International Nuclear Information System (INIS)

    Shou-xian, F.

    1994-01-01

    In the past decade, China has made great progress in developing high energy physics research. Since Beijing Electron Positron Collider (BEPC), the first high energy accelerator in China, realized collision in October 1988, it has experienced constant upgrading in performance. In the second half of 1991, the performance of BEPC reached a record high since its inception. The luminosity of BEPC at the energy of 2 GeV is 6 x 10 cm -2 s -1 with a lifetime of 8 to 10 hours. Operation has been very stable, trouble rate is less than 10% of the total operation time. The above fact shows that Chinese industry is able to meet the requirements of BEPC and BES (Beijing Spectrometer). Many components of BEPC and BES proved to be very reliable after long time operation. By the construction of BEPC, a batch of experienced and high-caliber scientists have been cultivated and an experienced operation team trained. All these have laid a good foundation for today's international cooperation

  12. Charm physics at BES III

    International Nuclear Information System (INIS)

    Wang Yifang

    2011-01-01

    Since the discovery of J/Ψ and the τ lepton in 70's, the study of τ-charm physics became very active: several dedicated e + e - colliders were built and tremendous progress were obtained. In this paper, the main reasoning,the content and the characteristics of the τ-charm physics study are discussed, together with the scientific motivations and the latest results of the recently completed upgrade of the Beijing Electron-Positron Collider (BEPC II) and the new Beijing Spectrometer (BES III). (authors)

  13. Early positron emission tomography response-adapted treatment in stage I and II hodgkin lymphoma

    DEFF Research Database (Denmark)

    André, Marc P.E.; Girinsky, Théodore; Federico, Massimo

    2017-01-01

    Purpose Patients who receive combined modality treatment for stage I and II Hodgkin lymphoma (HL) have an excellent outcome. Early response evaluation with positron emission tomography (PET) scan may improve selection of patients who need reduced or more intensive treatments. Methods We performed...

  14. Spectroscopic, Elemental and Thermal Analysis, and Positron Annihilation Studies on Ca(II), Sr(II), Ba(II), Pb(II), and Fe(III) Penicillin G Potassium Complexes

    Science.gov (United States)

    Refat, M. S.; Sharshara, T.

    2015-11-01

    The [Pb(Pin)2] · 3H2O, [M(Pin)(H2O)2(Cl)] · nH2O (M = SrII, CaII or BaII; n = 0-1), and [Fe(Pin)2(Cl)(H2O)] · H2O penicillin G potassium (Pin) complexes were synthesized and characterized using elemental analyses, molar conductivity, thermal analysis and electronic spectroscopy techniques. The positron annihilation lifetime (PAL) and Doppler broadening (DB) techniques have been employed to probe the defects and structural changes of Pin ligand and its complexes. The PAL and DB line-shape parameters were discussed in terms of the structure, molecular weight, ligand-metal molar ratio, and other properties of the Pin complexes.

  15. Fast and Precise Beam Energy Measurement using Compton Backscattering at e+e- Colliders

    CERN Document Server

    Kaminskiy, V V; Muchnoi, N Yu; Zhilich, V N

    2017-01-01

    The report describes a method for a fast and precise beam energy measurement in the beam energy range 0.5-2 GeV and its application at various e+e- colliders. Low-energy laser photons interact head-on with the electron or positron beam and produce Compton backscattered photons whose energy is precisely measured by HPGe detector. The method allows measuring the beam energy with relative accuracy of ∼2-5.10-5. The method was successfully applied at VEPP-4M, VEPP-3, VEPP-2000 (BINP, Russia) and BEPC-II (IHEP, China).

  16. CFD ANALYSES ON THE COOLING FOR SCQ MAGNETS IN BEPC II UPGRADE

    International Nuclear Information System (INIS)

    HE, Z.H.; WANG, L.; TANK, H.M.; ZHANG, X.B.; JIA, L.X.

    2003-01-01

    A pair of superconducting interaction region quadrupole magnets in Beijing Electron-Positron Collider Upgrade (BEPCII) are to be cooled by supercritical helium in order to eliminate the flow instabilities in the constrained cooling channels. The fluid flow is simulated by the commercial computational dynamics fluid software. The heat loads to the superconducting quadrupole (SCQ) magnets from the radiation shields at 80 K and from the thermal conduction of mechanical supports are considered. The temperature distribution of the fluid in the liquid helium cooling channels, and the heat transfer in the SCQ magnet and by its supports are presented. The influence of mass flow rate on pressure drop in the cooling passage is analyzed

  17. Beta spectra. II-Positron spectra

    International Nuclear Information System (INIS)

    Grau, A.; Garcia-Torano, E.

    1981-01-01

    Using the Fermi theory of beta decay, the beta spectra for 30 positron emitters have been computed, introducing a correction factor for unique forbidden transitions. The spectra are ploted vs. energy, once normalised, and tabulated with the related Fermi functions. The average and median energies are calculated. (author)

  18. The electronic system of Beijing spectrometer

    International Nuclear Information System (INIS)

    Xi Deming

    1990-01-01

    Beijing Spectrometer (BES) in an experimental facility of high energy physics on Beijing Electron Positron Collider (BEPC). A brief description including the global design, the read out circuits, the performances and the recent status of its electronic system is presented

  19. Positrons in biomolecular systems. II

    International Nuclear Information System (INIS)

    Glass, J.C.; Graf, G.; Costabal, H.; Ewert, D.H.; English, L.

    1982-01-01

    Pickoff-annihilation parameters, as related to the free volume model, are shown to be indicators of structural fluctuations in membranes and membrane bound proteins. Nitrous oxide anesthetic induces lateral rigidity in a membrane, and an anesthetic mechanism is suggested. Conformational changes of (Na + ,K + )ATPase in natural membrane are observed with ATP and Mg-ion binding. New positron applications to active transport and photosynthetic systems are suggested. (Auth.)

  20. Online beam energy measurement of Beijing electron positron collider II linear accelerator

    Science.gov (United States)

    Wang, S.; Iqbal, M.; Liu, R.; Chi, Y.

    2016-02-01

    This paper describes online beam energy measurement of Beijing Electron Positron Collider upgraded version II linear accelerator (linac) adequately. It presents the calculation formula, gives the error analysis in detail, discusses the realization in practice, and makes some verification. The method mentioned here measures the beam energy by acquiring the horizontal beam position with three beam position monitors (BPMs), which eliminates the effect of orbit fluctuation, and is much better than the one using the single BPM. The error analysis indicates that this online measurement has further potential usage such as a part of beam energy feedback system. The reliability of this method is also discussed and demonstrated in this paper.

  1. Prospect of Particle Physics in China

    CERN Multimedia

    CERN. Geneva

    2008-01-01

    The Beijing Electron Positron Collider (BEPC) finished its running July 2005, with great success in both the Tau-Charm physics experiment and the synchrotron radiation light source. The latest Charm physics results from BEPC are reviewed, including the observation of the new resonance of X1835 with a possible explanation of the PPbar bound state. The major upgrade of BEPC into a double ring collider, so called BEPCII, will increase its luminosity by two orders of magnitude. The physics window of BEPCII is mainly the precision measurements in the Charm physics and the search for new phenomena. The construction of BEPCII is finished. The tuning of the storage ring goes smoothly. The synchrotron radiation facility of BEPCII opened to users with high performance since the end of 2006. The new detector BESIII has been moved into the interaction region June, and the joint commissioning started. The non-accelerator experiments in China are ...

  2. Microemulsion systems studied by positron annihilation techniques. II

    International Nuclear Information System (INIS)

    Lopez, R.; Olea, O.; Fucugauchi, L.A.

    1982-01-01

    The positron annihilation technique was applied to assess the effect of the double bond of the surfactant molecule on the microemulsion formation mechanism by replacing sodium stearate by sodium oleate in surfactant-cosurfactant-solvent-water systems. Diameters of microemulsions were measured by dynamic laser light scattering, and the obtained values concur with the present positron annihilation data. Structures of these microemulsions have been assessed by considering the available conformation and shapes of the surfactant-cosurfactant-solvent-assemblies. Volumes of the same aggregates have been calculated by taking into consideration the packing constraint imposed upon kink formation. (Auth.)

  3. Calculation of the detection efficiency in liquid scintillators. II. Single positron emitters

    International Nuclear Information System (INIS)

    Grau Malonda, A.; Garcia Torano, E.

    1982-01-01

    Counting efficiency as a function of the figure of merit for 30 positron emitters has been computed from the positron energy spectrum. Only the efficiency contribution of positrons has been taken into consideration. The contribution of the annihilation photons depending on the volume of the scintillator will be investigated in a near future. Efficiency vs figure of merit is plotted and tabulated. (Author) 19 refs

  4. Measurements of $\\jpsi$ decays into $\\omega\\pio$, $\\omega\\eta$, and $\\omega\\etap$

    OpenAIRE

    Ablikim, M.

    2005-01-01

    Based on $5.8 \\times 10^7 \\jpsi$ events collected with BESII at the Beijing Electron-Positron Collider (BEPC), the decay branching fractions of $\\jpsi\\to\\omega\\pio$, $\\omega\\eta$, and $\\omega\\etap$ are measured using different $\\eta$ and $\\etap$ decay modes. The results are higher than previous measurements. The $\\omega\\pio$ electromagnetic form factor is also obtained.

  5. Calculation of the detection efficiency in liquid scintillators. II. Single positron emitters; Calculo de la eficiencia de deteccion en liquidos centelleadores. II Nucleidos que se desintegran por emision simple de positrones

    Energy Technology Data Exchange (ETDEWEB)

    Grau Malonda, A.; Garcia Torano, E.

    1982-07-01

    Counting efficiency as a function of the figure of merit for 30 positron emitters has been computed from the positron energy spectrum. Only the efficiency contribution of positrons has been taken into consideration. The contribution of the annihilation photons depending on the volume of the scintillator will be investigated in a near future. Efficiency vs figure of merit is plotted and tabulated. (Author) 19 refs.

  6. BID-F1 and BID-F2 domains of Bartonella henselae effector protein BepF trigger together with BepC the formation of invasome structures.

    Science.gov (United States)

    Truttmann, Matthias C; Guye, Patrick; Dehio, Christoph

    2011-01-01

    The gram-negative, zoonotic pathogen Bartonella henselae (Bhe) translocates seven distinct Bartonella effector proteins (Beps) via the VirB/VirD4 type IV secretion system (T4SS) into human cells, thereby interfering with host cell signaling [1], [2]. In particular, the effector protein BepG alone or the combination of effector proteins BepC and BepF trigger massive F-actin rearrangements that lead to the establishment of invasome structures eventually resulting in the internalization of entire Bhe aggregates [2], [3]. In this report, we investigate the molecular function of the effector protein BepF in the eukaryotic host cell. We show that the N-terminal [E/T]PLYAT tyrosine phosphorylation motifs of BepF get phosphorylated upon translocation but do not contribute to invasome-mediated Bhe uptake. In contrast, we found that two of the three BID domains of BepF are capable to trigger invasome formation together with BepC, while a mutation of the WxxxE motif of the BID-F1 domain inhibited its ability to contribute to the formation of invasome structures. Next, we show that BepF function during invasome formation can be replaced by the over-expression of constitutive-active Rho GTPases Rac1 or Cdc42. Finally we demonstrate that BID-F1 and BID-F2 domains promote the formation of filopodia-like extensions in NIH 3T3 and HeLa cells as well as membrane protrusions in HeLa cells, suggesting a role for BepF in Rac1 and Cdc42 activation during the process of invasome formation.

  7. The task-to-task communication between computers

    International Nuclear Information System (INIS)

    Lin Shuzi; Zhang Bingyun; Zhao Weiren

    1992-01-01

    The task-to-task communication is used in the Institute of High Energy Physics. The BES (Beijing Spectrometer) uses the communication mode to take some of the BEPC (Beijing Electron Positron Collider) running parameters needed by BES experiments in a periodic time. The authors describe the principle of transparent task-to-task communication and how to use it in BES on-line data acquisition system

  8. The Upgrade of the Neutron Induced Positron Source NEPOMUC

    Science.gov (United States)

    Hugenschmidt, C.; Ceeh, H.; Gigl, T.; Lippert, F.; Piochacz, C.; Pikart, P.; Reiner, M.; Weber, J.; Zimnik, S.

    2013-06-01

    In summer 2012, the new NEutron induced POsitron Source MUniCh (NEPOMUC) was installed and put into operation at the research reactor FRM II. At NEPOMUC upgrade 80% 113Cd enriched Cd is used as neutron-gamma converter in order to ensure an operation time of 25 years. A structure of Pt foils inside the beam tube generates positrons by pair production. Moderated positrons leaving the Pt front foil are electrically extracted and magnetically guided to the outside of the reactor pool. The whole design, including Pt-foils, the electric lenses and the magnetic fields, has been improved in order to enhance both the intensity and the brightness of the positron beam. After adjusting the potentials and the magnetic guide and compensation fields an intensity of about 3·109 moderated positrons per second is expected. During the first start-up, the measured temperatures of about 90°C ensure a reliable operation of the positron source. Within this contribution the features and the status of NEPOMUC upgrade are elucidated. In addition, an overview of recent positron beam experiments and current developments at the spectrometers is given.

  9. Positron emission tomography with Positome, 2

    International Nuclear Information System (INIS)

    Nukui, Hideaki; Yamamoto, Y.L.; Thompson, C.J.; Feindel, W.

    1979-01-01

    Positron emission tomography with Positome II using 68 Ga-EDTA was performed in cases with brain tumor and cerebral arteriovenous malformation. A significant focal uptake in static study and hemodynamic changes in dynamic study were noted in all cases except one case with intracranial lipoma. Comparing this method with sup(99m) Tc-pertechnetate cerebral image study and computerized axial tomography, the diagnostic rate for detecting brain tumor was almost equal in all of these three methods. However, detecting and localizing was easier and clearer in static positron emission tomography with 68 Ga-EDTA than in sup(99m) Tc-pertechnetate cerebral image and computerized axial tomography without infusion of contrast medium. Furthermore, static positron emission tomography with 68 Ga-EDTA was superior to computerized axial tomography without infusion of contrast medium for detecting cerebral arteriovenous malformation. Concerning dynamic positron emission tomography with 68 Ga-EDTA, semiquantitative values obtained by this method correlated well with findings of computerized axial tomography and was thought to be more precise and in detail than the findings of sup(99m) Tc-pertechnetate cerebral image study. Summation of the previous studies about dynamic positron emission tomography with 77 Kr in occlusive cerebrovascular disease is also reported. In conclusion, static positron emission tomography with 68 Ga-EDTA is a very useful diagnostic method for detecting and localizing brain tumor and cerebral arteriovenous malformation without any attendant complications. Furthermore, a good combination of static and dynamic positron emission tomography and computerized axial tomography appear to be outstandingly effective for not only detecting the lesion but also understanding the pathophysiological aspect in cases with various intracranial lesions. (author)

  10. Positron annihilation in low-temperature rare gases. II. Argon and neon

    International Nuclear Information System (INIS)

    Canter, K.F.; Roellig, L.O.

    1975-01-01

    Lifetime measurements of slow-positron and ortho-positronium (o-Ps) annihilation were made in argon and neon gases at room temperature and below. The argon experiments cover the temperature range 115 to 300 0 K and the density range 0.0356 to 0.0726 g/cm 3 (approximately equal to 20 to 40 amagat). The slow-positron spectra in argon exhibit a departure from free-positron annihilation below 200 0 K. The departure becomes more marked as the temperature is lowered. No deviation from free o-Ps pickoff annihilation is observed in argon at low temperatures. The neon measurements cover the temperature range 30 to 300 0 K and the density range 0.032 to 0.89 g/cm 3 (approximately equal to 35 to 980 amagat). No effect of temperature on the slow-positron spectra throughout the temperature and density ranges investigated in neon is observed. The spectra are very exponential with a corresponding decay rate which is temperature as well as time independent and is directly proportional to density over the ranges investigated. The o-Ps data are more eventful in that the o-Ps lifetime at near-liquid densities is approximately 20 nsec, a factor of nearly 4 greater than the value obtained using the pickoff-annihilation coefficient obtained at lower densities. This is evidence for positronium-induced cavities in low-temperature neon. A brief discussion of the argon and neon results is given in the context of the explanations offered for the low-temperature effects observed in helium gas

  11. BID-F1 and BID-F2 domains of Bartonella henselae effector protein BepF trigger together with BepC the formation of invasome structures.

    Directory of Open Access Journals (Sweden)

    Matthias C Truttmann

    Full Text Available The gram-negative, zoonotic pathogen Bartonella henselae (Bhe translocates seven distinct Bartonella effector proteins (Beps via the VirB/VirD4 type IV secretion system (T4SS into human cells, thereby interfering with host cell signaling [1], [2]. In particular, the effector protein BepG alone or the combination of effector proteins BepC and BepF trigger massive F-actin rearrangements that lead to the establishment of invasome structures eventually resulting in the internalization of entire Bhe aggregates [2], [3]. In this report, we investigate the molecular function of the effector protein BepF in the eukaryotic host cell. We show that the N-terminal [E/T]PLYAT tyrosine phosphorylation motifs of BepF get phosphorylated upon translocation but do not contribute to invasome-mediated Bhe uptake. In contrast, we found that two of the three BID domains of BepF are capable to trigger invasome formation together with BepC, while a mutation of the WxxxE motif of the BID-F1 domain inhibited its ability to contribute to the formation of invasome structures. Next, we show that BepF function during invasome formation can be replaced by the over-expression of constitutive-active Rho GTPases Rac1 or Cdc42. Finally we demonstrate that BID-F1 and BID-F2 domains promote the formation of filopodia-like extensions in NIH 3T3 and HeLa cells as well as membrane protrusions in HeLa cells, suggesting a role for BepF in Rac1 and Cdc42 activation during the process of invasome formation.

  12. Positron-molecule interactions and corresponding positron attachment to molecules. As a basis for positron emission tomography (PET)

    International Nuclear Information System (INIS)

    Tachikawa, Masanori; Kimura, Mineo; Pichl, Lukas

    2007-01-01

    Through positron and electron interactions, they annihilate emitting primarily two gamma rays with 180-degree opposite directions. Positron spectroscopy using the characteristics of these gamma rays has been employed for analyzing various properties of material as well as for positron emission tomography (PET). However, its fundamental physics of positron-electron interactions and resulting features of emitting gamma rays are not well understood. By obtaining better understanding of positron interactions, it should become possible to provide the firm bases for positron spectroscopy in finer accuracy and quality. Here, we propose a significant mechanism for positron annihilation through positron attachment process, which may help increase the quality of positron spectroscopy. (author)

  13. Recent status and results from BES

    International Nuclear Information System (INIS)

    Wang, P.

    1994-01-01

    Recent results on the τ leptonic mass by the analysis of several one prong decay channels, the search of gluonium state near J/ψ which was proposed to explain the so-called ρπ puzzle, and some preliminary results of D s meson from BES (Beijing Electron Spectrometer) are reported. Future plans of upgrading BEPC (Beijing Electron-Positron Collider) and BES are also described. (author). 3 refs., 1 fig., 1 tab

  14. Positron-containing systems and positron diagnostics

    International Nuclear Information System (INIS)

    1978-01-01

    The results of the experimental and theoretical investigations are presented. Considered are quantum-mechanical calculations of wave functions describing the states of positron-containing atomic systems and of cross-sections of the processes characterizing different interactions, and also the calculations of the behaviour of positrons in gases in the presence of an electric field. The results of experimental tests are presented by the data describing the behaviour of positrons and positronium in liquids, polymers and elastomers, complex oxides and in different solids. New equipment and systems developed on the basis of current studies are described. Examined is a possibility of applying the methods of model and effective potentials for studying the bound states of positron systems and for calculating cross-sections of elementary processes of elastic and inelastic collisions with a positron involved. The experimental works described indicate new possibilities of the positron diagnosis method: investigation of thin layers and films of semiconductor materials, defining the nature of chemical bonds in semiconductors, determination of the dislocation density in deformed semiconductors, derivation of important quantitative information of the energy states of radiation defects in them

  15. Accelerator control systems in China

    International Nuclear Information System (INIS)

    Yao Chihyuan

    1992-01-01

    Three accelerator facilities were built in the past few years, the 2.8 GeV electron positron collider BEPC, the heavy ion SSC cyclotron accelerator HIRFL and the 800 MeV synchrotron radiation storage ring HESYRL. Aimed at different research areas, they represent a new generation of accelerator in China. This report describes the design philosophy, the structure, performance as well as future improvements of the control systems of the these facilities. (author)

  16. Free-volume characterization of nanostructurized substances by positron annihilation lifetime spectroscopy

    Science.gov (United States)

    Shpotyuk, O.; Ingram, A.; Shpotyuk, Ya.

    2018-02-01

    Methodological possibilities of positron annihilation lifetime (PAL) spectroscopy are examined to parameterize free-volume structural evolution processes in some nanostructurized substances obeying conversion from positronium (Ps) decaying to positron trapping. Unlike conventional x3-term fitting analysis based on admixed positron trapping and Ps decaying, the effect of nanostructurization is considered as occurring due to conversion from preferential Ps decaying in initial host matrix to positron trapping in modified (nanostructurized) host-guest matrix. The developed approach referred to as x3-x2-CDA (coupling decomposition algorithm) allows estimation defect-free bulk and defect-specific positron lifetimes of free-volume elements responsible for nanostructurization. The applicability of this approach is proved for some nanostructurized materials allowing free-volume changes through Ps-to-positron trapping conversion, such as (i) metallic Ag nanoparticles embedded in polymer matrix, (ii) structure-modification processes caused by swift heavy ions irradiation in polystyrene, and (iii) host-guest chemistry problems like water immersion in alumomagnesium spinel ceramics. This approach is considered to be used as test-indicator, separating processes of host-matrix nanostructurization due to embedded nanoparticles from uncorrelated changes in positron-trapping and Ps-decaying channels.

  17. High-resolution tomography of positron emitters with clustered pinhole SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Goorden, Marlies C; Beekman, Freek J [Section of Radiation Detection and Medical Imaging, Applied Sciences, Delft University of Technology, Mekelweg 15, 2629 JB Delft (Netherlands)], E-mail: m.c.goorden@tudelft.nl

    2010-03-07

    State-of-the-art small-animal single photon emission computed tomography (SPECT) enables sub-half-mm resolution imaging of radio-labelled molecules. Due to severe photon penetration through pinhole edges, current multi-pinhole SPECT is not suitable for high-resolution imaging of photons with high energies, such as the annihilation photons emitted by positron emitting tracers (511 keV). To deal with this edge penetration, we introduce here clustered multi-pinhole SPECT (CMP): each pinhole in a cluster has a narrow opening angle to reduce photon penetration. Using simulations, CMP is compared with (i) a collimator with traditional pinholes that is currently used for sub-half-mm imaging of SPECT isotopes (U-SPECT-II), and (ii), like (i) but with collimator thickness adapted to image high-energy photons (traditional multi-pinhole SPECT, TMP). At 511 keV, U-SPECT-II is able to resolve the 0.9 mm rods of an iteratively reconstructed Jaszczak-like capillary hot rod phantom, and while TMP only leads to small improvements, CMP can resolve rods as small as 0.7 mm. Using a digital tumour phantom, we show that CMP resolves many details not assessable with standard USPECT-II and TMP collimators. Furthermore, CMP makes it possible to visualize uptake of positron emitting tracers in sub-compartments of a digital mouse striatal brain phantom. This may open up unique possibilities for analysing processes such as those underlying the function of neurotransmitter systems. Additional potential of CMP may include (i) the imaging of other high-energy single-photon emitters (e.g. I-131) and (ii) localized imaging of positron emitting tracers simultaneously with single photon emitters, with an even better resolution than coincidence PET.

  18. Planned Positron Factory project

    International Nuclear Information System (INIS)

    Okada, Sohei

    1990-01-01

    The Japan Atomic Energy Research Institute, JAERI, has started, drafting a construction plan for the 'Positron Factory', in which intense energy-controllable monoenergetic positron beams are produced from pair-production reactions caused by high-energy electrons from a linac. The JAERI organized a planning committee to provide a basic picture for the Positron Factory. This article presents an overview of the interactions of positrons, intense positron sources and the research program and facilities planned for the project. The interactions of positrons and intense positron sources are discussed focusing on major characteristics of positrons in different energy ranges. The research program for the Positron Factory is then outlined, focusing on advanced positron annihilation techniques, positron spectroscopy (diffraction, scattering, channeling, microscopy), basic positron physics (exotic particle science), and positron beam technology. Discussion is also made of facilities required for the Positron Factory. (N.K.)

  19. Positron sources

    International Nuclear Information System (INIS)

    Chehab, R.

    1989-01-01

    A tentative survey of positron sources is given. Physical processes on which positron generation is based are indicated and analyzed. Explanation of the general features of electromagnetic interactions and nuclear β + decay makes it possible to predict the yield and emittance for a given optical matching system between the positron source and the accelerator. Some kinds of matching systems commonly used - mainly working with solenoidal fields - are studied and the acceptance volume calculated. Such knowledge is helpful in comparing different matching systems. Since for large machines, a significant distance exists between the positron source and the experimental facility, positron emittance has to be preserved during beam transfer over large distances and methods used for that purpose are indicated. Comparison of existing positron sources leads to extrapolation to sources for future linear colliders

  20. Positron-acoustic waves in an electron-positron plasma with an electron beam

    International Nuclear Information System (INIS)

    Nejoh, Y.N.

    1996-01-01

    The nonlinear wave structures of large-amplitude positron-acoustic waves are studied in an electron-positron plasma in the presence of an electron beam with finite temperature and hot electrons and positrons. The region where positron-acoustic waves exist is presented by analysing the structure of the pseudopotential. The region depends sensitively on the positron density, the positron temperature and the electron beam temperature. It is shown that the maximum amplitude of the wave decreases as the positron temperature increases, and the region of positron-acoustic waves spreads as the positron temperature increases. 11 refs., 5 figs

  1. Performance tests of a full scale prototype of the Belle II TOP counter with cosmic muons and 2.1 GeV/c positron beam

    Energy Technology Data Exchange (ETDEWEB)

    Hayakawa, Tomokatsu

    2014-12-01

    A time-of-propagation detector named TOP is a hadronic particle identification system for the Belle II experiment. We have produced a full scale prototype of the Belle II TOP counter and tested with cosmic muons at KEK and the 2.1 GeV/c positrons at SPring-8 LEPS beamline. The procedures for the quartz acceptance test and assembly worked well and the first quartz radiator was successfully fabricated. The obtained test data shows good agreement with Monte Carlo expectation. - Highlights: • We have successfully produced a full scale prototype of the Belle II TOP counter. • The prototype counter has been tested at KEK and SPring-8 LEPS beamline. • The obtained test data shows good agreement with Monte Carlo expectation.

  2. Positron sources

    International Nuclear Information System (INIS)

    Chehab, R.

    1994-01-01

    A tentative survey of positron sources is given. Physical processes on which positron generation is based are indicated and analyzed. Explanation of the general features of electromagnetic interactions and nuclear β + decay makes it possible to predict the yield and emittance for a given optical matching system between the positron source and the accelerator. Some kinds of matching systems commonly used - mainly working with solenoidal field - are studied and the acceptance volume calculated. Such knowledge is helpful in comparing different matching systems. Since for large machines, a significant distance exists between the positron source and the experimental facility, positron emittance has to be preserved during beam transfer over large distances and methods used for that purpose are indicated. Comparison of existing positron sources leads to extrapolation to sources for future linear colliders. Some new ideas associated with these sources are also presented. (orig.)

  3. Transmission positron microscopes

    International Nuclear Information System (INIS)

    Doyama, Masao; Kogure, Yoshiaki; Inoue, Miyoshi; Kurihara, Toshikazu; Yoshiie, Toshimasa; Oshima, Ryuichiro; Matsuya, Miyuki

    2006-01-01

    Immediate and near-future plans for transmission positron microscopes being built at KEK, Tsukuba, Japan, are described. The characteristic feature of this project is remolding a commercial electron microscope to a positron microscope. A point source of electrons kept at a negative high voltage is changed to a point source of positrons kept at a high positive voltage. Positional resolution of transmission microscopes should be theoretically the same as electron microscopes. Positron microscopes utilizing trapping of positrons have always positional ambiguity due to the diffusion of positrons

  4. Positron production in heavy ion collisions: Current status of the problem - II

    International Nuclear Information System (INIS)

    Ahmad, I.; Back, B.B.; Betts, R.R.; Dunford, R.W.; Last, J.; Kutschera, W.; Rhein, M.D.; Schiffer, J.P.; Wilt, P.; Wuosmaa, A.H.

    1994-01-01

    Narrow peaks have been observed at GSI Darmstadt in the energy spectra of positrons and sum-energy spectra of positron-electron pairs, produced in collisions of very heavy ions. To date, there is no satisfactory explanation of the origin of these lines although many differing models have been proposed. In this contribution, the authors describe the features of a new experiment aimed at the study of the line phenomenon and present the results of their first experiments. The specific goals of their experiment are to clarify the experimental situation regarding the lines through high-resolution, high-statistics data and, by direct measurement of the vector momenta of the peak pairs, to determine their kinematics

  5. BES detector

    International Nuclear Information System (INIS)

    Bai, J.Z.; Bian, Q.; Chen, G.M.; Chen, L.J.; Chen, S.N.; Chen, Y.Q.; Chen, Z.Q.; Chi, Y.K.; Cui, H.C.; Cui, X.Z.; Deng, S.S.; Deng, Y.W.; Ding, H.L.; Dong, B.Z.; Dong, X.S.; Du, X.; Du, Z.Z.; Feng, C.; Feng, Z.; Fu, Z.S.; Gao, C.S.; Gao, M.L.; Gao, S.Q.; Gao, W.X.; Gao, Y.N.; Gu, S.D.; Gu, W.X.; Guan, Y.Z.; Guo, H.F.; Guo, Y.N.; Guo, Y.Y.; Han, S.W.; Han, Y.; Hao, W.; He, J.; He, K.R.; He, M.J.; Hou, X.J.; Hu, G.Y.; Hu, J.S.; Hu, J.W.; Huang, D.Q.; Huang, Y.Z.; Jia, Q.P.; Jiang, C.H.; Ju, Q.; Lai, Y.F.; Lang, P.F.; Li, D.S.; Li, F.; Li, H.; Li Jia; Li, J.T.; Li Jin; Li, L.L.; Li, P.Q.; Li, Q.M.; Li, R.B.; Li, S.Q.; Li, W.; Li, W.G.; Li, Z.X.; Liang, G.N.; Lin, F.C.; Lin, S.Z.; Lin, W.; Liu, Q.; Liu, R.G.; Liu, W.; Liu, X.; Liu, Z.A.; Liu, Z.Y.; Lu, C.G.; Lu, W.D.; Lu, Z.Y.; Lu, J.G.; Ma, D.H.; Ma, E.C.; Ma, J.M.; Mao, H.S.; Mao, Z.P.; Meng, X.C.; Ni, H.L.; Nie, J.; Nie, Z.D.; Niu, W.P.; Pan, L.J.; Qi, N.D.; Qian, J.J.; Qu, Y.H.; Que, Y.K.; Rong, G.; Ruan, T.Z.; Shao, Y.Y.; Shen, B.W.; Shen, D.L.; Shen, J.; Sheng, H.Y.; Sheng, J.P.; Shi, H.Z.; Song, X.F.; Sun, H.S.; Tang, F.K.; Tang, S.Q.; Tian, W.H.; Wang, F.; Wang, G.Y.; Wang, J.G.; Wang, J.Y.; Wang, L.S.; Wang, L.Z.; Wang, M.; Wang, P.; Wang, P.L.; Wang, S.M.; Wang, S.Q.; Wang, T.J.; Wang, X.W.; Wang, Y.Y.; Wang, Z.H.; Wang, Z.J.; Wei, C.L.; Wei, Z.Z.; Wu, J.W.; Wu, S.H.; Wu, S.Q.; Wu, W.M.; Wu, X.D.; Wu, Z.D.; Xi, D.M.; Xia, X.M.; Xiao, J.; Xie, P.P.; Xie, X.X.; Xu, J.G.; Xu, R.S.; Xu, Z.Q.; Xuan, B.C.; Xue, S.T.; Yan, J.; Yan, S.P.; Yan, W.G.; Yang, C.Z.; Yang, C.M.; Yang, C.Y.; Yang, X.F.; Yang, X.R.; Ye, M.H.; Yu, C.H.; Yu, C.S.; Yu, Z.Q.; Zhang, B.Y.; Zhang, C.D.; Zhang, C.C.; Zhang, C.Y.; Zhang, D.H.; Zhang, G.; Zhang, H.Y.; Zhang, H.L.; Zhang, J.W.; Zhang, L.S.; Zhang, S.Q.; Zhang, Y.P.; Zhang, Y.; Zhang, Y.M.; Zhao, D.X.; Zhao, J.W.; Zhao, M.; Zhao, P.D.; Zhao, P.P.; Zhao, W.R.; Zhao, Z.G.; Zhao, Z.Q.; Zheng, J.P.; Zheng, L.S.; Zheng, M.; Zheng, W.S.; Zheng, Z.P.; Zhong, G.P.; Zhou, G.P.; Zhou, H.S.; Zhou, J.; Zhou Li; Zhou Lin; Zhou, M.; Zhou, Y.S.; Zhou, Y.H.; Zhu, G.S.; Zhu, Q.M.; Zhu, S.G.; Zhu, Y.C.; Zhu, Y.S.; Zhuang, B.A.

    1994-01-01

    The Beijing Spectrometer (BES) is a general purpose solenoidal detector at the Beijing Electron Positron Collider (BEPC). It is designed to study exclusive final states in e + e - annihilations at the center of mass energy from 3.0 to 5.6 GeV. This requires large solid angle coverage combined with good charged particle momentum resolution, good particle identification and high photon detection efficiency at low energies. In this paper we describe the construction and the performance of BES detector. (orig.)

  6. Development of an Electron-Positron Source for Positron Annihilation Lifetime Spectroscopy

    Science.gov (United States)

    2009-12-19

    REPORT Development of an electron- positron source for positron annihilation lifetime spectroscopy : FINAL REPORT 14. ABSTRACT 16. SECURITY...to generate radiation, to accelerate particles, and to produce electrons and positrons from vacuum. From applications using existing high-repetition...theoretical directions. This report reviews work directed toward the application of positron generation from laser interaction with matter 1. REPORT DATE

  7. Large-dimension configuration-interaction calculations of positron binding to the group-II atoms

    International Nuclear Information System (INIS)

    Bromley, M. W. J.; Mitroy, J.

    2006-01-01

    The configuration-interaction (CI) method is applied to the calculation of the structures of a number of positron binding systems, including e + Be, e + Mg, e + Ca, and e + Sr. These calculations were carried out in orbital spaces containing about 200 electron and 200 positron orbitals up to l=12. Despite the very large dimensions, the binding energy and annihilation rate converge slowly with l, and the final values do contain an appreciable correction obtained by extrapolating the calculation to the l→∞ limit. The binding energies were 0.00317 hartree for e + Be, 0.0170 hartree for e + Mg, 0.0189 hartree for e + Ca, and 0.0131 hartree for e + Sr

  8. Investigation of positron moderator materials for electron-linac-based slow positron beamlines

    International Nuclear Information System (INIS)

    Suzuki, Ryoichi; Ohdaira, Toshiyuki; Uedono, Akira

    1998-01-01

    Positron re-emission properties were studied on moderator materials in order to improve the positron moderation system of electron-linac-based intense slow positron beamlines. The re-emitted positron fraction was measured on tungsten, SiC, GaN, SrTiO 3 , and hydrogen-terminated Si with a variable-energy pulsed positron beam. The results suggested that tungsten is the best material for the primary moderator of the positron beamlines while epitaxially grown n-type 6H-SiC is the best material for the secondary moderator. Defect characterization by monoenergetic positron beams and surface characterization by Auger electron spectroscopy were carried out to clarify the mechanism of tungsten moderator degradation induced by high-energy electron irradiation. The characterization experiments revealed that the degradation is due to both radiation-induced vacancy clusters and surface carbon impurities. For the restoration of degraded tungsten moderators, oxygen treatment at ∼900degC is effective. Furthermore, it was found that oxygen at the tungsten surface inhibits positronium formation; as a result, it can increase the positron re-emission fraction. (author)

  9. Positron astrophysics and areas of relation to low-energy positron physics

    Science.gov (United States)

    Guessoum, Nidhal

    2014-05-01

    I briefly review our general knowledge of positron astrophysics, focusing mostly on the theoretical and modelling aspects. The experimental/observational aspects of the topic have recently been reviewed elsewhere [E. Churazov et al., Mon. Nat. R. Astron. Soc. 411, 1727 (2011); N. Prantazos et al., Rev. Mod. Phys. 83, 1001 (2011)]. In particular, I highlight the interactions and cross sections of the reactions that the positrons undergo in various cosmic media. Indeed, these must be of high interest to both the positron astrophysics community and the low-energy positron physics community in trying to find common areas of potential collaboration for the future or areas of research that will help the astrophysics community make further progress on the problem. The processes undergone by positrons from the moments of their birth to their annihilation (in the interstellar medium or other locations) are thus examined. The physics of the positron interactions with gases and solids (dust grains) and the physical conditions and characteristics of the environments where the processes of energy loss, positronium formation, and annihilation take place, are briefly reviewed. An explanation is given about how all the relevant physical information is taken into account in order to calculate annihilation rates and spectra of the 511 keV emission in the ISM; special attention is paid to positron interactions with dust and with polycyclic aromatic hydrocarbons. In particular, an attempt is made to show to what extent the interactions between positrons and interstellar dust grains are similar to laboratory experiments in which beams of low-energy positrons impinge upon solids and surfaces. Sample results are shown for the effect of dust grains on positron annihilation spectra in some phases of the ISM which, together with high resolution spectra measured by satellites, can be used to infer useful knowledge about the environment where the annihilation is predominantly taking place

  10. Positron-atom collisions

    International Nuclear Information System (INIS)

    Drachman, R.J.

    1984-01-01

    The past decade has seen the field of positron-atom collisions mature into an important sub-field of atomic physics. Increasingly intense positron sources are leading towards a situation in which electron and positron collision experiments will be on almost an equal footing, challenging theory to analyze their similarities and differences. The author reviews the advances made in theory, including dispersion theory, resonances, and inelastic processes. A survey of experimental progress and a brief discussion of astrophysical positronics is also included. (Auth.)

  11. Positron astrophysics and areas of relation to low-energy positron physics

    International Nuclear Information System (INIS)

    Guessoum, N.

    2014-01-01

    I briefly review our general knowledge of positron astrophysics, focusing mostly on the theoretical and modelling aspects. The experimental/observational aspects of the topic have recently been reviewed elsewhere [E. Churazov et al., Mon. Nat. R. Astron. Soc. 411, 1727 (2011); N. Prantazos et al., Rev. Mod. Phys. 83, 1001 (2011)]. In particular, I highlight the interactions and cross sections of the reactions that the positrons undergo in various cosmic media. Indeed, these must be of high interest to both the positron astrophysics community and the low-energy positron physics community in trying to find common areas of potential collaboration for the future or areas of research that will help the astrophysics community make further progress on the problem. The processes undergone by positrons from the moments of their birth to their annihilation (in the interstellar medium or other locations) are thus examined. The physics of the positron interactions with gases and solids (dust grains) and the physical conditions and characteristics of the environments where the processes of energy loss, positronium formation, and annihilation take place, are briefly reviewed. An explanation is given about how all the relevant physical information is taken into account in order to calculate annihilation rates and spectra of the 511 keV emission in the ISM; special attention is paid to positron interactions with dust and with polycyclic aromatic hydrocarbons. In particular, an attempt is made to show to what extent the interactions between positrons and interstellar dust grains are similar to laboratory experiments in which beams of low-energy positrons impinge upon solids and surfaces. Sample results are shown for the effect of dust grains on positron annihilation spectra in some phases of the ISM which, together with high resolution spectra measured by satellites, can be used to infer useful knowledge about the environment where the annihilation is predominantly taking place

  12. Synthesis and characterization of magnesium oxide nanocrystallites and probing the vacancy-type defects through positron annihilation studies

    Science.gov (United States)

    Das, Anjan; Mandal, Atis Chandra; Roy, Soma; Prashanth, Pendem; Ahamed, Sk Izaz; Kar, Subhrasmita; Prasad, Mithun S.; Nambissan, P. M. G.

    2016-09-01

    Magnesium oxide nanocrystallites exhibit certain abnormal characteristics when compared to those of other wide band gap oxide semiconductors in the sense they are most prone to water absorption and formation of a hydroxide layer on the surface. The problem can be rectified by heating and pure nanocrystallites can be synthesized with controllable sizes. Inevitably the defect properties are distinctly divided between two stages, the one with the hydroxide layer (region I) and the other after the removal of the layer by annealing (region II). The lattice parameters, the optical band gap and even the positron annihilation characteristics are conspicuous by their distinct behavior in the two stages of the surface configurations of nanoparticles. While region I was specific with the formation of positronium-hydrogen complexes that drastically altered the defect-specific positron lifetimes, pick-off annihilation of orthopositronium atoms marked region II. The vacancy clusters within the nanocrystallites also trapped positrons. They agglomerated due to the effect of the higher temperatures and resulted in the growth of the nanocrystallites. The coincidence Doppler broadening spectroscopic measurements supported these findings and all the more indicated the trapping of positrons additionally into the neutral divacancies and negatively charged trivacancies. This is apart from the Mg2+ monovacancies which acted as the dominant trapping centers for positrons.

  13. Positrons and positronium

    International Nuclear Information System (INIS)

    Jean, Y.C.; Lambrecht, R.M.

    1988-01-01

    This bibliography includes articles, proceedings, abstracts, reports and patents published between 1930 and 1984 on the subject of positrons, positron annihilation and positronium. The subject covers experimental and theoretical results in the areas of physics and chemistry of low and intermediate energy (< 0.6 MeV) positrons and positronium. The topics of interest are: fundamental properties, interactions with matter, nuclear technology, the history and philosophy of antimatter, the theory of the universe, and the applications of positrons in the chemical, physical, and biomedical sciences

  14. Application of positron annihilation spectroscopy for investigation of reactor steels

    International Nuclear Information System (INIS)

    Sojak, S.; Slugen, V.; Petriska, M.; Stacho, M.; Veternikova, J.; Sabelova, V.; Egger, W.; Ravelli, L.

    2013-01-01

    Our work is focused on the study of radiation damage simulated by ion implantations and thermal treatment evaluation of RAFM steels in the form of binary Fe-Cr model alloys. In order to study the microstructure recovery after ion irradiation, we applied an approach for restoration of initial physical and mechanical characteristics of structural materials in the form of thermal annealing, with the goal to decrease the size and amount of accumulated defects. The experimental analysis of material damage at microstructural level was performed by the pulsed low energy positron system (PLEPS) [1] at the high intensity positron source NEPOMUC at the Munich research reactor FRM-II. (authors)

  15. The proposed INEL intense slow positron source, beam line, and positron microscope facility

    International Nuclear Information System (INIS)

    Makowitz, H.; Denison, A.B.; Brown, B.

    1993-01-01

    A program is currently underway at the Idaho National Engineering Laboratory (INEL) to design and construct an Intense Slow Positron Beam Facility with an associated Positron Microscope. Positron beams have been shown to be valuable research tools and have potential application in industrial processing and nondestructive evaluation (microelectronics, etc.). The limit of resolution or overall usefulness of the technique has been limited because of lack of sufficient intensity. The goal of the INEL positron beam is ≥ 10 12 slow e+/s over a 0.03 cm diameter which represents a 10 3 to 10 4 advancement in beam current over existing beam facilities. The INEL is an ideal site for such a facility because of the nuclear reactors capable of producing intense positron sources and the personnel and facilities capable of handling high levels of radioactivity. A design using 58 Co with moderators and remoderators in conjunction with electrostatic positron beam optics has been reached after numerous computer code studies. Proof-of-principle electron tests have demonstrated the feasibility of the large area source focusing optics. The positron microscope development is occurring in conjunction with the University of Michigan positron microscope group. Such a Beam Facility and associated Intense Slow Positron Source (ISPS) can also be utilized for the generation and study of positron, and positron electron plasmas at ≤ 10 14 particles/cm 3 with plasma temperatures ranging from an eV to many keV, as well as an intense x-ray source via positron channeling radiation. The possibility of a tunable x-ray laser based on channeling positron radiation also exists. In this discussion the authors will present a progress report on various activities associated with the INEL ISPS

  16. Positron emission tomography

    International Nuclear Information System (INIS)

    Reivich, M.; Alavi, A.

    1985-01-01

    This book contains 24 selections. Some of the titles are: Positron Emission Tomography Instrumentation, Generator Systems for Positron Emitters, Reconstruction Algorithms, Cerebral Glucose Consumption: Methodology and Validation, Cerebral Blood Flow Tomography Using Xenon-133 Inhalation: Methods and Clinical Applications, PET Studies of Stroke, Cardiac Positron Emission Tomography, and Use of PET in Oncology

  17. Work station for low temperature positron annihilation studies

    International Nuclear Information System (INIS)

    Chaturvedi, T.P.; Venkiteswaran, S.; Pujari, P.K.

    1999-05-01

    This report describes the automation implemented in the low temperature Positron Annihilation Spectroscopy studies system. Temperature programmer and controller (Lakeshore 330) is interfaced to PC-AT through an IEEE-488 add-on card. Through this data can be read and written to the temperature controller and it can be handled remotely. The PC- AT also houses the PCA-II card. Software (TEMP330.EXE) was developed to communicate with the temperature controller. A master software is also developed under which TEMP330.EXE and PCAII.EXE should run. Another program DATASEG.EXE creates a user file to store the temperature points given by user over which data acquisition is required. This has not only widened the scope of the positron research, but also helps achieve result with better precision. (author)

  18. Cardiac positron emission tomography

    International Nuclear Information System (INIS)

    Eftekhari, M.; Ejmalian, G.

    2003-01-01

    Positron emission tomography is an intrinsically tool that provide a unique and unparalleled approach for clinicians and researchers to interrogate the heart noninvasively. The ability to label substances of physiological interest with positron-emitting radioisotopes has permitted insight into normal blood flow and metabolism and the alterations that occur with disease states. Positron emission tomography of the heart has evolved as a unique, noninvasive approach for the assessment of myocardial perfusion, metabolism, and function. Because of the intrinsic quantitative nature of positron emission tomography measurements as well as the diverse compounds that can be labeled with positron- emitting radioisotopes, studies with positron emission tomography have provided rich insight into the physiology of the heart under diverse conditions

  19. Positron studies of defected metals, metallic surfaces

    International Nuclear Information System (INIS)

    Bansil, A.

    1991-01-01

    Specific problems proposed under this project included the treatment of electronic structure and momentum density in various disordered and defected systems. Since 1987, when the new high-temperature superconductors were discovered, the project focused extensively on questions concerning the electronic structure and Fermiology of high-T c superconductors, in particular, (i) momentum density and positron experiments, (ii) angle-resolved photoemission intensities, (iii) effects of disorder and substitutions in the high-T c 's

  20. Positron annihilation studies on bulk metallic glass and high intensity positron beam developments

    International Nuclear Information System (INIS)

    Asoka-Kumar, P.; Stoeffl, W.

    2003-01-01

    Positron annihilation spectroscopy is an ideal probe to examine atomic scale open-volume regions in materials. Below, we summarize the recent results on studies of open-volume regions of a multicomponent Zr-Ti-Ni-Cu-Be bulk metallic glass. Our studies establish two types of open-volume regions, one group that is too shallow to trap positrons at room temperature and becomes effective only at low temperatures and the other group that localizes positrons at room temperature and is large enough to accommodate hydrogen. The second half of the paper will concentrate on the high intensity positron program at Lawrence Livermore National Laboratory. A new positron production target is under development and we are constructing two experimental end stations to accommodate a pulsed positron microprobe and an experiment on positron diffraction and holography. Important design considerations of these experiments will be described. (author)

  1. Positron emission tomography

    International Nuclear Information System (INIS)

    Paans, A.M.J.

    1981-01-01

    Positron emitting radiopharmaceuticals have special applications in in-vivo studies of biochemical processes. The combination of a cyclotron for the production of radionuclides and a positron emission tomograph for the registration of the distribution of radioactivity in the body enables the measurement of local radioactivity concentration in tissues, and opens up new possibilities in the diagnosis and examination of abnormalities in the metabolism. The principles and procedures of positron emission tomography are described and the necessary apparatus considered, with emphasis on the positron camera. The first clinical applications using 55 Co bloemycine for tumor detection are presented. (C.F.)

  2. New techniques of positron annihilation

    International Nuclear Information System (INIS)

    1983-02-01

    Studies on new techniques of positron annihilation and its application to various fields are presented. First, production of slow positron and its characteristic features are described. The slow positron can be obtained from radioisotopes by using a positron moderator, proton beam bombardment on a boron target, and pair production by using an electron linear accelerator. Bright enhancement of the slow positron beam is studied. Polarized positron beam can be used for the study of the momentum distribution of an electron in ferromagnetic substances. Production of polarized positrons and measurements of polarization are discussed. Various phases of interaction between slow positrons and atoms (or molecules) are described. A comparative study of electron scavenging effects on luminescence and on positronium formation in cyclohexane is presented. The positron annihilation phenomena are applicable for the surface study. The microscopic information on the surface of porous material may be obtained. The slow positrons are also useful for the surface study. Production and application of slow muon (positive and negative) are presented in this report. (Kato, T.)

  3. Solvated Positron Chemistry - Positron Reactions with Pseudo-Halide Ions in Water

    DEFF Research Database (Denmark)

    Mogensen, O. E.; Pedersen, Niels Jørgen; Andersen, Jan Rud

    1982-01-01

    The hydrated positron e+aq reactions with SCN−, OCN−, CN−, S2− were studied by means of the angular correlation technique. The positron forms bound states with SCN−, CN−, and S2− but not with OCN−. Apparently, the e+aq reaction with SH− results in a positron bound state with S2−. It was difficult...

  4. Direct measurement of the Ds branching fraction to φπ

    International Nuclear Information System (INIS)

    Bai, J.Z.; Bardon, O.; Blum, I.; Breakstone, A.; Burnett, T.; Chen, G.P.; Chen, H.F.; Chen, J.; Chen, S.J.; Chen, S.M.; Chen, Y.; Chen, Y.B.; Chen, Y.Q.; Cheng, B.S.; Cowan, R.F.; Cui, H.C.; Cui, X.Z.; Ding, H.L.; Du, Z.Z.; Dunwoodie, W.; Fan, X.L.; Fang, J.; Fero, M.; Gao, C.S.; Gao, M.L.; Gao, S.Q.; Gao, W.X.; Gratton, P.; Gu, J.H.; Gu, S.D.; Gu, W.X.; Gu, Y.F.; Guo, Y.N.; Han, S.W.; Han, Y.; Harris, F.A.; Hatanaka, M.; He, J.; He, K.R.; He, M.; Hitlin, D.G.; Hu, G.Y.; Hu, H.B.; Hu, T.; Hu, X.Q.; Huang, D.Q.; Huang, Y.Z.; Izen, J.M.; Jia, Q.P.; Jiang, C.H.; Jin, Y.; Jones, L.; Kang, S.H.; Kelsey, M.H.; Kim, B.K.; Lai, Y.F.; Lan, H.B.; Lang, P.F.; Lankford, A.; Li, F.; Li, J.; Li, P.Q.; Li, Q.; Li, R.B.; Li, W.; Li, W.D.; Li, W.G.; Li, X.; Li, X.N.; Lin, S.Z.; Liu, H.M.; Liu, J.H.; Liu, Q.; Liu, R.G.; Liu, Y.; Liu, Z.A.; Lou, X.C.; Lowery, B.; Lu, J.G.; Ma, A.M.; Ma, E.C.; Ma, J.M.; Mao, H.S.; Mao, Z.P.; Malchow, R.; Mandelkern, M.; Meng, X.C.; Ni, H.L.; Nie, J.; Olsen, S.L.; Oyang, J.; Paluselli, D.; Pan, L.J.; Panetta, J.; Porter, F.; Prabhakar, E.; Qi, N.D.; Que, Y.K.; Quigley, J.; Rong, G.; Schernau, M.; Schmid, B.; Schultz, J.; Shao, Y.Y.; Shen, D.L.; Shen, H.; Shen, X.Y.; Sheng, H.Y.; Shi, H.Z.; Shi, X.R.; Smith, A.; Soderstrom, E.; Song, X.F.; Standifird, J.; Stoker, D.; Sun, F.; Sun, H.S.; Sun, S.J.; Synodinos, J.; Tan, Y.P.; Tang, S.Q.; Toki, W.; Tong, G.L.; Torrence, E.; Wang, F.; Wang, L.S.; Wang, L.Z.; Wang, M.; Wang, P.; Wang, P.L.; Wang, S.M.; Wang, T.J.; Wang, W.; Wang, Y.Y.; Whittaker, S.; Wilson, R.; Wisniewski, W.J.; Xi, D.M.; Xia, X.M.; Xie, P.P.; Xu, D.Z.; Xu, R.S.; Xu, Z.Q.; Xue, S.T.; Yamamoto, R.; Yan, J.; Yan, W.G.; Yang, C.M.; Yang, C.Y.; Yang, W.; Yao, H.B.; Ye, M.H.; Ye, S.Z.; Yu, C.S.; Yu, C.X.; Yu, Z.Q.; Yuan, C.Z.; Zhang, B.Y.; Zhang, C.C.; Zhang, D.H.; Zhang, H.L.; Zhang, J.; Zhang, J.W.; Zhang, L.S.; Zhang, S.Q.; Zhang, Y.; Zhang, Y.Y.; Zhao, D.X.; Zhao, J.W.; Zhao, M.; Zhao, P.D.; Zhao, W.R.; Zhao, W.X.; Zheng, J.H.

    1995-01-01

    The Beijing Spectrometer (BES) Collaboration has observed exclusive pair production of D s mesons at the Beijing Electron-Positron Collider (BEPC) at a center-of-mass energy of 4.03 GeV. The D s mesons are detected in the φπ + , bar K *0 K + , and bar K 0 K + decay modes; two fully reconstructed events yield the value (3.9 -1.9-1.1 +5.1+1.8 )% for the D s branching fraction to φπ. This is the first direct, model-independent measurement of this quantity

  5. Positron-Induced Luminescence

    Science.gov (United States)

    Stenson, E. V.; Hergenhahn, U.; Stoneking, M. R.; Pedersen, T. Sunn

    2018-04-01

    We report on the observation that low-energy positrons incident on a phosphor screen produce significantly more luminescence than electrons do. For two different wide-band-gap semiconductor phosphors (ZnS:Ag and ZnO:Zn), we compare the luminescent response to a positron beam with the response to an electron beam. For both phosphors, the positron response is significantly brighter than the electron response, by a factor that depends strongly on incident energy (0-5 keV). Positrons with just a few tens of electron-volts of energy (for ZnS:Ag) or less (for ZnO:Zn) produce as much luminescence as is produced by electrons with several kilo-electron-volts. We attribute this effect to valence band holes and excited electrons produced by positron annihilation and subsequent Auger processes. These results demonstrate a valuable approach for addressing long-standing questions about luminescent materials.

  6. Positron Factory project

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Sohei; Sunaga, Hiromi; Kaneko, Hirohisa; Kawasuso, Atsuo; Masuno, Shin-ichi; Takizawa, Haruki; Yotsumoto, Keiichi [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

    1997-03-01

    We have started drafting a construction program for the Positron Factory, in which linac-based intense monoenergetic positron beams are planned to be applied for materials science, biotechnology and basic physics and chemistry. A technical survey study confirmed the feasibility of manufacturing a dedicated electron linac of 100 kW class with a beam energy of 100 MeV, which will produce a world-highest monoenergetic positron beam of more than 10{sup 10}/sec in intensity. A self-driven rotating converter (electrons to positrons and photons) suitable for the high power electron beam was devised and successfully tested. The practicability of simultaneous extraction of multi-channel monoenergetic positron beams with multiple moderator assemblies, which had been originated on the basis of a Monte Carlo simulation, was demonstrated by an experiment using an electron linac. An efficient moderator structure, which is composed of honeycomb-like assembled moderator foils and reflectors, is also proposed. (author)

  7. KEK-IMSS Slow Positron Facility

    Energy Technology Data Exchange (ETDEWEB)

    Hyodo, T; Wada, K; Yagishita, A; Kosuge, T; Saito, Y; Kurihara, T; Kikuchi, T; Shirakawa, A; Sanami, T; Ikeda, M; Ohsawa, S; Kakihara, K; Shidara, T, E-mail: toshio.hyodo@kek.jp [High Energy Accelerator Research Organization (KEK) 1-1 Oho, Tsukuba, Ibaraki, 305-0801 (Japan)

    2011-12-01

    The Slow Positron Facility at the Institute of Material Structure Science (IMSS) of High Energy Accelerator Research Organization (KEK) is a user dedicated facility with an energy tunable (0.1 - 35 keV) slow positron beam produced by a dedicated 55MeV linac. The present beam line branches have been used for the positronium time-of-flight (Ps-TOF) measurements, the transmission positron microscope (TPM) and the photo-detachment of Ps negative ions (Ps{sup -}). During the year 2010, a reflection high-energy positron diffraction (RHEPD) measurement station is going to be installed. The slow positron generator (converter/ moderator) system will be modified to get a higher slow positron intensity, and a new user-friendly beam line power-supply control and vacuum monitoring system is being developed. Another plan for this year is the transfer of a {sup 22}Na-based slow positron beam from RIKEN. This machine will be used for the continuous slow positron beam applications and for the orientation training of those who are interested in beginning researches with a slow positron beam.

  8. Positron deposition in plasmas by positronium beam ionization and transport of positrons in tokamak plasmas

    International Nuclear Information System (INIS)

    Murphy, T.J.

    1986-11-01

    In a recently proposed positron transport experiment, positrons would be deposited in a fusion plasma by forming a positronium (Ps) beam and passing it through the plasma. Positrons would be deposited as the beam is ionized by plasma ions and electrons. Radial transport of the positrons to the limiter could then be measured by detecting the gamma radiation produced by annihilation of positrons with electrons in the limiter. This would allow measurements of the transport of electron-mass particles and might shed some light on the mechanisms of electron transport in fusion plasmas. In this paper, the deposition and transport of positrons in a tokamak are simulated and the annihilation signal determined for several transport models. Calculations of the expected signals are necessary for the optimal design of a positron transport experiment. There are several mechanisms for the loss of positrons besides transport to the limiter. Annihilation with plasma electrons and reformation of positronium in positron-hydrogen collisions are two such processes. These processes can alter the signal and place restrictions ons on the plasma conditions in which positron transport experiments can be effectively performed

  9. Defect identification using positrons

    International Nuclear Information System (INIS)

    Beling, C.D.; Fung, S.

    2001-01-01

    The current use of the lifetime and Doppler broadening techniques in defect identification is demonstrated with two studies, the first being the identification of carbon vacancy in n-6H SiC through lifetime spectroscopy, and the second the production of de-hydrogenated voids in α-Si:H through light soaking. Some less conventional ideas are presented for more specific defect identification, namely (i) the amalgamation of lifetime and Doppler techniques with conventional deep level transient spectroscopy in what may be called ''positron-deep level transient spectroscopy'', and (ii) the extraction of more spatial information on vacancy defects by means of what may be called ''Fourier transform Doppler broadening of annihilation radiation spectroscopy'' (orig.)

  10. A transmission positron microscope and a scanning positron microscope being built at KEK, Japan

    International Nuclear Information System (INIS)

    Doyama, M.; Inoue, M.; Kogure, Y.; Kurihara, T.; Yagishita, A.; Shidara, T.; Nakahara, K.; Hayashi, Y.; Yoshiie, T.

    2001-01-01

    This paper reports the plans of positron microscopes being built at KEK (High Energy Accelerator Research Organization), Tsukuba, Japan improving used electron microscopes. The kinetic energies of positron produced by accelerators or by nuclear decays have not a unique value but show a spread over in a wide range. Positron beam will be guided near electron microscopes, a transmission electron microscope (JEM100S) and a scanning electron microscope (JSM25S). Positrons are slowed down by a tungsten foil, accelerated and focused on a nickel sheet. The monochromatic focused beam will be injected into an electron microscope. The focusing of positrons and electrons is achieved by magnetic system of the electron microscopes. Imaging plates are used to record positron images for the transmission electron microscope. (orig.)

  11. Positron emission computed tomography

    International Nuclear Information System (INIS)

    Grover, M.; Schelbert, H.R.

    1985-01-01

    Regional mycardial blood flow and substrate metabolism can be non-invasively evaluated and quantified with positron emission computed tomography (Positron-CT). Tracers of exogenous glucose utilization and fatty acid metabolism are available and have been extensively tested. Specific tracer kinetic models have been developed or are being tested so that glucose and fatty acid metabolism can be measured quantitatively by Positron-CT. Tracers of amino acid and oxygen metabolism are utilized in Positron-CT studies of the brain and development of such tracers for cardiac studies are in progress. Methods to quantify regional myocardial blood flow are also being developed. Previous studies have demonstrated the ability of Positron-/CT to document myocardial infarction. Experimental and clinical studies have begun to identify metabolic markers of reversibly ischemic myocardium. The potential of Positron-CT to reliably detect potentially salvageable myocardium and, hence, to identify appropriate therapeutic interventions is one of the most exciting applications of the technique

  12. Theory, development, and applications of the scanning positron microbeam and positron reemission microscope

    International Nuclear Information System (INIS)

    Brandes, G.R.

    1990-01-01

    The theory, design, development, and applications of two new imaging instruments, the scanning positron microbeam (SPM) and positron reemission microscope (PRM), are discussed. The SPM consists of a sectored lens which focuses and rasters the positrons from the beam across the sample. The results of rastering the 10μm x 50μm beam across a test grid demonstrate the SPM's ability to scan a 500μm diameter region and to resolve features with ∼ 5μm resolution. The SPM was used to examine the location of defects in a Si-on-SiO 2 sample. Possible applications to three dimensional defect spectroscopy and the observation of small samples are considered. In the PRM, the positrons from the brightness-enhanced beam are focused at 5keV to an 8/Am diameter spot (FWHM) onto a thin metal single crystal. An image of the opposing side of the film is formed by accelerating and focusing the reemitted thermalized positrons with a cathode lens objective and a projector lens. The final image (real) is a record of the thermal positron emission intensity versus position. Images of surface and subsurface defect structures, taken at magnifications up to 4400x and with a resolution up to 80nm, are presented and discussed. The ultimate resolution capabilities and possible applications of the PRM are examined. The implantation and diffusion process of positrons was studied with the PRM by examining the positron emission profile of 3-9keV positrons implanted into a 2200 angstrom thick Ni single crystal

  13. Positron studies in catalysis research

    International Nuclear Information System (INIS)

    1994-01-01

    During the past eight months, the authors have made progress in several areas relevant to the eventual use of positron techniques in catalysis research. They have come closer to the completion of their positron microscope, and at the same time have performed several studies in their non-microscopic positron spectrometer which should ultimately be applicable to catalysis. The current status of the efforts in each of these areas is summarized in the following sections: Construction of the positron microscope (optical element construction, data collection software, and electronic sub-assemblies); Doppler broadening spectroscopy of metal silicide; Positron lifetime spectroscopy of glassy polymers; and Positron lifetime measurements of pore-sizes in zeolites

  14. 22 Na positron source for annihilation positron spectroscopy

    International Nuclear Information System (INIS)

    Cimpeanu, Catalina; Craciun, L.; Dragulescu, E.; Dudu, D.; Racolta, P. M.; Voiculescu, Dana; Miron, N.

    2003-01-01

    To extend the nuclear physics applications and to perform the study of vacancy - type defects in metals, semiconductors, polymers etc., we decided to promote positron annihilation techniques. In order to achieve this goal we started a project of dedicated positron sources produced at the IFIN-HH U-120 Cyclotron. We have used the nuclear reaction: 24 Mg(d,α) 22 Na with deuterons of 13 MeV energy. The paper presents the main characteristics of this procedure, as follows: general conditions asked for 22 NaCl sources, reactive chamber and characteristics of Mg target, parameters for the irradiation, radiochemical procedures for separating Na from Mg after the irradiation and geometrical or mechanical requirements for dedicated NaCl source for positron annihilation spectrometry. In the e + lifetime measurements, the e + end - start signals may be obtained from prompt γ -quanta emitted from the NaCl source (1. 275 MeV photons). The 22 NaCl stock solution obtained by radiochemical separation will be kept in quartz sealed ampoules in dry places and will be dropped between the study materials before the use in positron spectrometry. (authors)

  15. Slow positron applications at slow positron facility of institute of materials structure science, KEK

    Science.gov (United States)

    Hyodo, Toshio; Mochizuki, Izumi; Wada, Ken; Toge, Nobukazu; Shidara, Tetsuo

    2018-05-01

    Slow Positron Facility at High Energy Accelerator Research Organization (KEK) is a user dedicated facility with an energy-tunable (0.1 - 35 keV) slow positron beam created by a dedicated ˜ 50 MeV linac. It operates in a short pulse (width 1-12 ns, variable, 5×106 e+/s) and a long pulse (width 1.2 µs, 5×107 e+/s) modes of 50 Hz. High energy positrons from pair creation are moderated by reemission after thermalization in W foils. The reemitted positrons are then electrostatically accelerated to a desired energy up to 35 keV and magnetically transported. A pulse-stretching section (pulse stretcher) is installed in the middle of the beamline. It stretches the slow positron pulse for the experiments where too many positrons annihilating in the sample at the same time has to be avoided. Four experiment stations for TRHEPD (total-reflection high-energy positron diffraction), LEPD (low-energy positron diffraction), Ps- (positronium negative ion), and Ps-TOF (positronium time-of-flight) experiments are connected to the beamline branches, SPF-A3, SPF-A4, SPF-B1 and SPF-B2, respectively. Recent results of these stations are briefly described.

  16. SPEAR II performance

    International Nuclear Information System (INIS)

    Paterson, J.M.

    1975-01-01

    The single beam and colliding beam performance of the SLAC electron-positron storage ring SPEAR II is described. The sevenfold increase in harmonic number in SPEAR II in comparison to SPEAR I has made significant changes in single beam behavior. Strong synchrobetatron resonances and a new transverse instability are observed, and our first studies of these phenomena are described. Measurements on current dependent bunch lengthening are presented. (auth)

  17. Positron and positronium studies of irradiation-induced defects and microvoids in vitreous metamict silica

    International Nuclear Information System (INIS)

    Hasegawa, M.; Saneyasu, M.; Tabata, M.; Tang, Z.; Nagai, Y.; Chiba, T.; Ito, Y.

    2000-01-01

    To study irradiation-induced defects and structural microvoids in vitreous silica (v-SiO 2 ), positron lifetime, angular correlation of positron annihilation radiation (ACAR), and electron spin resonance (ESR) were measured on v-SiO 2 and quartz (c-SiO 2 ) samples irradiated with fast neutrons up to a dose of 4.1x10 20 n/cm 2 . Two kinds of positron-trapping defects have been found to form in v-SiO 2 by fast neutron irradiation: type-I and type-II defects. Similar defects also appear in the irradiated c-SiO 2 , indicating that both the defects are common in v-SiO 2 and c-SiO 2 . The detailed annealing and photo-illumination studies of positron annihilation and ESR for these two defects suggest that the type-I defects are non-bridging oxygen hole centers (NBOHC), while the type-II defects are oxygen molecules which cannot be detected by ESR. Higher dose irradiation than 1.0x10 20 n/cm 2 causes c-SiO 2 to change to metamict (amorphous) phase (m-SiO 2 ). Positronium (Ps) atoms are found to form in microvoids with an average radius of about 0.3 nm in the v-SiO 2 and m-SiO 2 . This suggests that microvoids proved by Ps are structurally intrinsic open spaces and reflect the topologically disordered structure of these phases in the subnanometer scale

  18. Positron effective mass in silicon

    International Nuclear Information System (INIS)

    Panda, B.K.; Shan, Y.Y.; Fung, S.; Beling, C.D.

    1995-01-01

    The positron effective mass in Si is obtained from the first-principles calculations along various crystallographic directions. The effect of electron-positron correlation on the band mass is examined in this work. A positron pseudopotential scheme is worked out to calculate the isotropic band mass without explicitly solving the band energy. The effective mass 1.46m obtained as a sum of band mass and the positron-plasmon interaction compares very well with 1.5m obtained from the positron mobility data

  19. Beam induced vacuum measurement error in BEPC II

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    When the beam in BEPCII storage ring aborts suddenly, the measured pressure of cold cathode gauges and ion pumps will drop suddenly and decrease to the base pressure gradually. This shows that there is a beam induced positive error in the pressure measurement during beam operation. The error is the difference between measured and real pressures. Right after the beam aborts, the error will disappear immediately and the measured pressure will then be equal to real pressure. For one gauge, we can fit a non-linear pressure-time curve with its measured pressure data 20 seconds after a sudden beam abortion. From this negative exponential decay pumping-down curve, real pressure at the time when the beam starts aborting is extrapolated. With the data of several sudden beam abortions we have got the errors of that gauge in different beam currents and found that the error is directly proportional to the beam current, as expected. And a linear data-fitting gives the proportion coefficient of the equation, which we derived to evaluate the real pressure all the time when the beam with varied currents is on.

  20. Positron emission tomography

    International Nuclear Information System (INIS)

    Iio, Masahiro

    1982-01-01

    Utilization of positron emission tomography was reviewed in relation to construction and planned construction of small-size medical cyclotrons, planned construction of positron cameras and utilization of short-lived radionuclides. (Chiba, N.)

  1. Generation of a high-brightness pulsed positron beam for the Munich scanning positron microscope

    Energy Technology Data Exchange (ETDEWEB)

    Piochacz, Christian

    2009-11-20

    Within the present work the prerequisites for the operation of the Munich scanning positron microscope (SPM) at the high intense neutron induced positron source Munich (NEPOMUC) were established. This was accomplished in two steps: Firstly, a re-moderation device was installed at the positron beam facility NEPOMUC, which enhances the brightness of the positron beam for all connected experiments. The second step was the design, set up and initial operation of the SPM interface for the high efficient conversion of the continuous beam into a bunched beam. The in-pile positron source NEPOMUC creates a positron beam with a diameter of typically 7 mm, a kinetic energy of 1 keV and an energy spread of 50 eV. The NEPOMUC re-moderator generates from this beam a low energy positron beam (20 - 200 eV) with a diameter of less than 2 mm and an energy spread well below 2.5 eV. This was achieved with an excellent total efficiency of 6.55{+-}0.25 %. The re-moderator was not only the rst step to implement the SPM at NEPOMUc, it enables also the operation of the pulsed low energy positron beam system (PLEPS). Within the present work, at this spectrometer rst positron lifetime measurements were performed, which revealed the defect types of an ion irradiated uranium molybdenum alloy. Moreover, the instruments which were already connected to the positron beam facility bene ts considerably of the high brightness enhancement. In the new SPM interface an additional re-moderation stage enhances the brightness of the beam even more and will enable positron lifetime measurements at the SPM with a lateral resolution below 1 {mu}m. The efficiency of the re-moderation process in this second stage was 24.5{+-}4.5 %. In order to convert high efficiently the continuous positron beam into a pulsed beam with a repetition rate of 50 MHz and a pulse duration of less than 50 ps, a sub-harmonic pre-bucher was combined with two sine wave bunchers. Furthermore, the additional re-moderation stage of the

  2. Generation of a high-brightness pulsed positron beam for the Munich scanning positron microscope

    International Nuclear Information System (INIS)

    Piochacz, Christian

    2009-01-01

    Within the present work the prerequisites for the operation of the Munich scanning positron microscope (SPM) at the high intense neutron induced positron source Munich (NEPOMUC) were established. This was accomplished in two steps: Firstly, a re-moderation device was installed at the positron beam facility NEPOMUC, which enhances the brightness of the positron beam for all connected experiments. The second step was the design, set up and initial operation of the SPM interface for the high efficient conversion of the continuous beam into a bunched beam. The in-pile positron source NEPOMUC creates a positron beam with a diameter of typically 7 mm, a kinetic energy of 1 keV and an energy spread of 50 eV. The NEPOMUC re-moderator generates from this beam a low energy positron beam (20 - 200 eV) with a diameter of less than 2 mm and an energy spread well below 2.5 eV. This was achieved with an excellent total efficiency of 6.55±0.25 %. The re-moderator was not only the rst step to implement the SPM at NEPOMUc, it enables also the operation of the pulsed low energy positron beam system (PLEPS). Within the present work, at this spectrometer rst positron lifetime measurements were performed, which revealed the defect types of an ion irradiated uranium molybdenum alloy. Moreover, the instruments which were already connected to the positron beam facility bene ts considerably of the high brightness enhancement. In the new SPM interface an additional re-moderation stage enhances the brightness of the beam even more and will enable positron lifetime measurements at the SPM with a lateral resolution below 1 μm. The efficiency of the re-moderation process in this second stage was 24.5±4.5 %. In order to convert high efficiently the continuous positron beam into a pulsed beam with a repetition rate of 50 MHz and a pulse duration of less than 50 ps, a sub-harmonic pre-bucher was combined with two sine wave bunchers. Furthermore, the additional re-moderation stage of the SPM

  3. Elementary particle physics. Progress report, July 1992--October 1994

    International Nuclear Information System (INIS)

    Izen, J.M.

    1994-10-01

    The University of Texas at Dallas (UTD) is participating in two e + e - , experiments, Beijing Spectrometer (BES) and BABAR, the PEP-11 B Factory detector. The UTD group consists of Profs. Joseph M. Izen and Xinchou Lou, seven Ph.D. students. A post-doc is requested to join them in this work. BES explores the physics of the τ-charm threshold region. Associated production of τ and charmed mesons allow for absolute branching fraction measurements with good control of backgrounds. BES is uniquely positioned to study the leptonic and hadronic decays of quarkonia. The Beijing Electron Positron Collider (BEPC) delivers luminosities an order of magnitude higher than earlier facilities. BES and BEPC will be upgraded following the 1994-5 run, and will resume data taking in Fall, 1996 with an improved detector and a Three-fold increase in luminosity. The raison d'etre of BABAR is the exploration of CP violation in the B meson system. An asymmetric storage ring is required to observe the time-dependence of the CP asymmetry. Other BABAR physics includes measurements of CKM matrix elements, rare B decays, penguin diagrams, B s decays, and precision measurements of τ and D meson decays. The scheduled BABAR turn-on in 1999 provides the UTD group with a natural evolution with continuous physics during this period. Professors Joseph M. Izen and Xinchou Lou are leading the BES and BABAR program at UTD. Both have specialized in e + e - collider experiments and share 22 years of experience at the SPEAR, BEPC, CESR, PETRA, SLC and LEP rings

  4. Positron sources for electron-positron colliders application to the ILC and CLIC

    CERN Multimedia

    CERN. Geneva

    2008-01-01

    The increased demanding qualities for positron sources dedicated to e+e- colliders pushed on investigations oriented on new kinds of e+ sources. The different kinds of positron sources polarized and no polarized are considered. Their main features (intensity, emittance) are described and analysed. Comparison between the different sources is worked out. The characteristics of the positron beam available in the collision point are greatly depending on the capture device and on the positron accelerator. Different kinds of capture systems are considered and their qualities, compared. Intense positron sources which are necessary for the colliders require intense incident beams (electrons or photons). The large number of pairs created in the targets leads to important energy deposition and so, thermal heating, which associated to temperature gradients provoke mechanical stresses often destructive. Moreover, the important Coulomb collisions, can affect the atomic structure in crystal targets and the radiation resist...

  5. High current pulsed positron microprobe

    International Nuclear Information System (INIS)

    Howell, R.H.; Stoeffl, W.; Kumar, A.; Sterne, P.A.; Cowan, T.E.; Hartley, J.

    1997-01-01

    We are developing a low energy, microscopically focused, pulsed positron beam for defect analysis by positron lifetime spectroscopy to provide a new defect analysis capability at the 10 10 e + s -l beam at the Lawrence Livermore National Laboratory electron linac. When completed, the pulsed positron microprobe will enable defect specific, 3-dimensional maps of defect concentrations with sub-micron resolution of defect location. By coupling these data with first principles calculations of defect specific positron lifetimes and positron implantation profiles we will both map the identity and concentration of defect distributions

  6. Efficient Cryosolid Positron Moderators

    Science.gov (United States)

    2012-08-01

    table layout Figure 21 shows the integration of the IR spectroscopy optics with the positron Moderation and Annihilation vacuum chambers on the...Characterization of Cryogenic Moderators The application of Matrix Isolation Spectroscopy (MIS) to characterizing cryogenic solid positron ...Matrix Isolation Spectroscopy capability into our Positron Moderation apparatus, which enables spectroscopic characterization of the cryogenic

  7. Positron annihilation in a metal-oxide semiconductor studied by using a pulsed monoenergetic positron beam

    Science.gov (United States)

    Uedono, A.; Wei, L.; Tanigawa, S.; Suzuki, R.; Ohgaki, H.; Mikado, T.; Ohji, Y.

    1993-12-01

    The positron annihilation in a metal-oxide semiconductor was studied by using a pulsed monoenergetic positron beam. Lifetime spectra of positrons were measured as a function of incident positron energy for a polycrystalline Si(100 nm)/SiO2(400 nm)/Si specimen. Applying a gate voltage between the polycrystalline Si film and the Si substrate, positrons implanted into the specimen were accumulated at the SiO2/Si interface. From the measurements, it was found that the annihilation probability of ortho-positronium (ortho-Ps) drastically decreased at the SiO2/Si interface. The observed inhibition of the Ps formation was attributed to an interaction between positrons and defects at the SiO2/Si interface.

  8. 22 Na positron source for annihilation positron spectroscopy

    International Nuclear Information System (INIS)

    Cimpeanu, Catalina; Craciun, L.; Dragulescu, E.; Dudu, D.; Racolta, P.M.; Voiculescu, Dana; Miron, N.

    2002-01-01

    To extend the nuclear physics applications and to perform the study of vacancy - type defects in metals, semiconductors, polymers etc., we decided to promote positron annihilation techniques. In order to achieve this goal we started a project of dedicated positron sources produced at the IFIN-HH U-120 Cyclotron. We have used the nuclear reaction 24 Mg(d,α) 22 Na and deuterons of 13 MeV energy. The paper presents the main steps of this procedure like: general conditions required for 22 NaCl sources, reactive chamber and characteristics of Mg target, parameters for the irradiation, radiochemical procedures to separate Na from Mg after the irradiation and geometrical or mechanical requirements for dedicated NaCl source for positron annihilation spectrometry. In the e + lifetime measurements the e + 'death - stop' signals are always provided by γ - quanta generated by the e + e - annihilation and the 'birth - start' signals may be obtained from 'prompt' γ - quanta emitted from the NaCl source (the 1.275 MeV photons). The 22 NaCl stock solution obtained by radiochemical separation will be kept in the sealed quartz vials in dry places and will be dropped between the studied materials before use in positron spectrometry. (authors)

  9. Positron Beam Characteristics at NEPOMUC Upgrade

    Science.gov (United States)

    Hugenschmidt, C.; Ceeh, H.; Gigl, T.; Lippert, F.; Piochacz, C.; Reiner, M.; Schreckenbach, K.; Vohburger, S.; Weber, J.; Zimnik, S.

    2014-04-01

    In 2012, the new neutron induced positron source NEPOMUC upgrade was put into operation at FRMII. Major changes have been made to the source which consists of a neutron-γ-converter out of Cd and a Pt foil structure for electron positron pair production and positron moderation. The new design leads to an improvement of both intensity and brightness of the mono-energetic positron beam. In addition, the application of highly enriched 113Cd as neutron-γ-converter extends the lifetime of the positron source to 25 years. A new switching and remoderation device has been installed in order to allow toggling from the high-intensity primary beam to a brightness enhanced remoderated positron beam. At present, an intensity of more than 109 moderated positrons per second is achieved at NEPOMUC upgrade. The main characteristics are presented which comprise positron yield and beam profile of both the primary and the remoderated positron beam.

  10. Positron emission tomography

    International Nuclear Information System (INIS)

    Wienhard, K.; Heiss, W.D.

    1984-01-01

    The principles and selected clinical applications of positron emission tomography are described. In this technique a chemical compound is labeled with a positron emitting isotope and its biochemical pathway is traced by coincidence detection of the two annihilation photons. The application of the techniques of computed tomography allows to reconstruct the spatial distribution of the radioactivity within a subject. The 18 F-deoxyglucose method for quantitative measurement of local glucose metabolism is discussed in order to illustrate the possibilities of positron emission tomography to record physiological processes in vivo. (orig.) [de

  11. Application of mathematical removal of positron range blurring in positron emission tomography

    International Nuclear Information System (INIS)

    Haber, S.F.; Derenzo, S.E.; Uber, D.

    1990-01-01

    The range of positrons in tissue is an important limitation to the ultimate spatial resolution achievable in positron emission tomography. In this work the authors have applied a Fourier deconvolution technique to remove range blurring in images taken by the Donner 600-crystal positron tomograph. Using phantom data, the authors have found significant improvement in the image quality and the FWHM for both 68 Ga and 82 Rb. These were successfully corrected so that the images and FWHM almost matched those of 18 F which has negligible positron range. However, statistical noise was increased by the deconvolution process and it was not practical to recover the full spatial resolution of the tomograph

  12. Positron Annihilation in Insulating Materials

    International Nuclear Information System (INIS)

    Asoka-Kumar, P; Sterne, PA

    2002-01-01

    We describe positron results from a wide range of insulating materials. We have completed positron experiments on a range of zeolite-y samples, KDP crystals, alkali halides and laser damaged SiO 2 . Present theoretical understanding of positron behavior in insulators is incomplete and our combined theoretical and experimental approach is aimed at developing a predictive understanding of positrons and positronium annihilation characteristics in insulators. Results from alkali halides and alkaline-earth halides show that positrons annihilate with only the halide ions, with no apparent contribution from the alkali or alkaline-earth cations. This contradicts the results of our existing theory for metals, which predicts roughly equal annihilation contributions from cation and anion. We also present result obtained using Munich positron microprobe on laser damaged SiO 2 samples

  13. Applications of slow positrons to cancer research: Search for selectivity of positron annihilation to skin cancer

    International Nuclear Information System (INIS)

    Jean, Y.C.; Li Ying; Liu Gaung; Chen, Hongmin; Zhang Junjie; Gadzia, Joseph E.

    2006-01-01

    Slow positrons and positron annihilation spectroscopy (PAS) have been applied to medical research in searching for positron annihilation selectivity to cancer cells. We report the results of positron lifetime and Doppler broadening energy spectroscopies in human skin samples with and without cancer as a function of positron incident energy (up to 8 μm depth) and found that the positronium annihilates at a significantly lower rate and forms at a lower probability in the samples having either basal cell carcinoma (BCC) or squamous cell carcinoma (SCC) than in the normal skin. The significant selectivity of positron annihilation to skin cancer may open a new research area of developing positron annihilation spectroscopy as a novel medical tool to detect cancer formation externally and non-invasively at the early stages

  14. Applications of slow positrons to cancer research: Search for selectivity of positron annihilation to skin cancer

    Energy Technology Data Exchange (ETDEWEB)

    Jean, Y.C. [Department of Chemistry, University of Missouri-Kansas City, 205 Spenscer Chemistry Building, 5009 Rockhill Road, Kansas City, MO 64110 (United States)]. E-mail: jeany@umkc.edu; Li Ying [Department of Chemistry, University of Missouri-Kansas City, 205 Spenscer Chemistry Building, 5009 Rockhill Road, Kansas City, MO 64110 (United States); Liu Gaung [Department of Chemistry, University of Missouri-Kansas City, 205 Spenscer Chemistry Building, 5009 Rockhill Road, Kansas City, MO 64110 (United States); Chen, Hongmin [Department of Chemistry, University of Missouri-Kansas City, 205 Spenscer Chemistry Building, 5009 Rockhill Road, Kansas City, MO 64110 (United States); Zhang Junjie [Department of Chemistry, University of Missouri-Kansas City, 205 Spenscer Chemistry Building, 5009 Rockhill Road, Kansas City, MO 64110 (United States); Gadzia, Joseph E. [Dermatology, Department of Internal Medicine, University of Kansas Medical Center, Kansas City, KS 66103 (United States); Kansas Medical Clinic, Topeka, KS 66614 (United States)

    2006-02-28

    Slow positrons and positron annihilation spectroscopy (PAS) have been applied to medical research in searching for positron annihilation selectivity to cancer cells. We report the results of positron lifetime and Doppler broadening energy spectroscopies in human skin samples with and without cancer as a function of positron incident energy (up to 8 {mu}m depth) and found that the positronium annihilates at a significantly lower rate and forms at a lower probability in the samples having either basal cell carcinoma (BCC) or squamous cell carcinoma (SCC) than in the normal skin. The significant selectivity of positron annihilation to skin cancer may open a new research area of developing positron annihilation spectroscopy as a novel medical tool to detect cancer formation externally and non-invasively at the early stages.

  15. Positron Survival in Type II Supernovae

    Science.gov (United States)

    1989-05-01

    B: Computer Program and Flow Diagram 53 References 59 I. Introduction Since the discovery of Supernova 1987A (a Type II supernova) in February of 1987...the fewer number of decays depositing energy within the supernova. The rate of this cooling is unknown because it is uncertain whether a pulsar was

  16. Positron lifetime measurements and positron-annihilation induced auger electron spectroscpy using slow positron beams; Teisoku yodenshi bimu wo mochiita yodenshi jumyo sokutei oyobi yodenshi shometsu reiki oje denshi bunko

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, R. [Electrotechnical Lab., Tsukuba (Japan)

    1996-02-20

    Slow positron beam with less than several eV can be controlled freely such as accelerating, throttling the beam size, shortening the pulse or making pulse with short time width and so forth. These low positron beams are applied to various measurements like Doppler broadening measurement of annihilation {gamma} rays or lifetime measurement of positron, and secondary particle measurements using positron microscope, positron electron ray diffraction, flight time method and so forth. In particular, these recent years, high intensity slow positron beams were possible using accelerators like electron linac and its application is increasing. In this report, pulse shortening method for high intensity slow positron beam, and incidence energy variable positron lifetime measurement method using this slow pulsed beam and flight time type positron-annihilation-induced auger electron spectroscopy are outlined. In future, these measurements can be possible to carry out with high resolution and also with high counting rate if higher intensity monochromatic excellent positron beam than present one is produced. 31 refs., 5 figs.

  17. LLNL pure positron plasma program

    International Nuclear Information System (INIS)

    Hartley, J.H.; Beck, B.R.; Cowan, T.E.; Howell, R.H.; McDonald, J.L.; Rohatgi, R.R.; Fajans, J.; Gopalan, R.

    1995-01-01

    Assembly and initial testing of the Positron Time-of-Flight Trap at the Lawrence Livermore National Laboratory (LLNL) Increase Pulsed Positron Facility has been completed. The goal of the project is to accumulate at high-density positron plasma in only a few seconds., in order to facilitate study that may require destructive diagnostics. To date, densities of at least 6 x 10 6 positrons per cm 3 have been achieved

  18. Bruno Touschek: From Betatrons to Electron-Positron Colliders

    Science.gov (United States)

    Bernardini, Carlo; Pancheri, Giulia; Pellegrini, Claudio

    Bruno Touschek’s life as a physicist spanned the period from World War II to the 1970s. He was a key figure in the developments of electron-positron colliders and storage rings, and made important contributions to theoretical high energy physics. Storage rings, initially developed for high energy physics, are being widely used in many countries as synchrotron radiation sources and are a tool for research in physics, chemistry, biology, environmental sciences and cultural heritage studies. We describe Touschek’s life in Austria, where he was born, in Germany, where he participated in the construction of a betatron during WWII, and in Italy, where he proposed and led to completion the first electron-positron storage ring in 1960, in Frascati. We highlight how his central European culture influenced his lifestyle and work, and his main contributions to physics, such as the discovery of the Touschek effect and beam instabilities in the larger storage ring ADONE.

  19. High resolution positron tomography

    International Nuclear Information System (INIS)

    Brownell, G.L.; Burnham, C.A.

    1982-01-01

    The limits of spatial resolution in practical positron tomography are examined. The four factors that limit spatial resolution are: positron range; small angle deviation; detector dimensions and properties; statistics. Of these factors, positron range may be considered the fundamental physical limitation since it is independent of instrument properties. The other factors are to a greater or lesser extent dependent on the design of the tomograph

  20. Positron emission tomography

    NARCIS (Netherlands)

    Paans, AMJ

    Positron Emission Tomography (PET) is a method for determining biochemical and physiological processes in vivo in a quantitative way by using radiopharmaceuticals labelled with positron emitting radionuclides as C-11, N-13, O-15 and F-18 and by measuring the annihilation radiation using a

  1. Beam test of CSES silicon strip detector module

    Science.gov (United States)

    Zhang, Da-Li; Lu, Hong; Wang, Huan-Yu; Li, Xin-Qiao; Xu, Yan-Bing; An, Zheng-Hua; Yu, Xiao-xia; Wang, Hui; Shi, Feng; Wang, Ping; Zhao, Xiao-Yun

    2017-05-01

    The silicon-strip tracker of the China Seismo-Electromagnetic Satellite (CSES) consists of two double-sided silicon strip detectors (DSSDs) which provide incident particle tracking information. A low-noise analog ASIC VA140 was used in this study for DSSD signal readout. A beam test on the DSSD module was performed at the Beijing Test Beam Facility of the Beijing Electron Positron Collider (BEPC) using a 400-800 MeV/c proton beam. The pedestal analysis results, RMSE noise, gain correction, and intensity distribution of incident particles of the DSSD module are presented. Supported by the XXX Civil Space Programme

  2. Positron confinement in embedded lithium nanoclusters

    Science.gov (United States)

    van Huis, M. A.; van Veen, A.; Schut, H.; Falub, C. V.; Eijt, S. W.; Mijnarends, P. E.; Kuriplach, J.

    2002-02-01

    Quantum confinement of positrons in nanoclusters offers the opportunity to obtain detailed information on the electronic structure of nanoclusters by application of positron annihilation spectroscopy techniques. In this work, positron confinement is investigated in lithium nanoclusters embedded in monocrystalline MgO. These nanoclusters were created by means of ion implantation and subsequent annealing. It was found from the results of Doppler broadening positron beam analysis that approximately 92% of the implanted positrons annihilate in lithium nanoclusters rather than in the embedding MgO, while the local fraction of lithium at the implantation depth is only 1.3 at. %. The results of two-dimensional angular correlation of annihilation radiation confirm the presence of crystalline bulk lithium. The confinement of positrons is ascribed to the difference in positron affinity between lithium and MgO. The nanocluster acts as a potential well for positrons, where the depth of the potential well is equal to the difference in the positron affinities of lithium and MgO. These affinities were calculated using the linear muffin-tin orbital atomic sphere approximation method. This yields a positronic potential step at the MgO||Li interface of 1.8 eV using the generalized gradient approximation and 2.8 eV using the insulator model.

  3. Simulation of the annihilation emission of galactic positrons; Modelisation de l'emission d'annihilation des positrons Galactiques

    Energy Technology Data Exchange (ETDEWEB)

    Gillard, W

    2008-01-15

    Positrons annihilate in the central region of our Galaxy. This has been known since the detection of a strong emission line centered on an energy of 511 keV in the direction of the Galactic center. This gamma-ray line is emitted during the annihilation of positrons with electrons from the interstellar medium. The spectrometer SPI, onboard the INTEGRAL observatory, performed spatial and spectral analyses of the positron annihilation emission. This thesis presents a study of the Galactic positron annihilation emission based on models of the different interactions undergone by positrons in the interstellar medium. The models are relied on our present knowledge of the properties of the interstellar medium in the Galactic bulge, where most of the positrons annihilate, and of the physics of positrons (production, propagation and annihilation processes). In order to obtain constraints on the positrons sources and physical characteristics of the annihilation medium, we compared the results of the models to measurements provided by the SPI spectrometer. (author)

  4. Mining the bulk positron lifetime

    International Nuclear Information System (INIS)

    Aourag, H.; Guittom, A.

    2009-01-01

    We introduce a new approach to investigate the bulk positron lifetimes of new systems based on data-mining techniques. Through data mining of bulk positron lifetimes, we demonstrate the ability to predict the positron lifetimes of new semiconductors on the basis of available semiconductor data already studied. Informatics techniques have been applied to bulk positron lifetimes for different tetrahedrally bounded semiconductors in order to discover computational design rules. (copyright 2009 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  5. Solvated Positron Chemistry. Competitive Positron Reactions with Halide Ions in Water

    DEFF Research Database (Denmark)

    Christensen, Palle; Pedersen, Niels Jørgen; Andersen, J. R.

    1979-01-01

    It is shown by means of the angular correlation technique that the binding of positrons to halides is strongly influenced by solvation effects. For aqueous solutions we find increasing values for the binding energies between the halide and the positron with increasing mass of the halide...

  6. Development of a transmission positron microscope

    Energy Technology Data Exchange (ETDEWEB)

    Matsuya, M., E-mail: matsuya@jeol.co.jp [JEOL Ltd., 1-2 Musashino, 3-Chome, Akishima, Tokyo 196-8558 (Japan); Jinno, S. [Department of Applied Chemistry, Chiba University, Yayoi, Inage, Chiba, Chiba 263-8552 (Japan); Ootsuka, T.; Inoue, M. [JEOL Ltd., 1-2 Musashino, 3-Chome, Akishima, Tokyo 196-8558 (Japan); Kurihara, T. [High Energy Accelerator Research Organization, Oho, Tsukuba, Ibaraki 305-0801 (Japan); Doyama, M.; Inoue, M. [Teikyo University of Science and Technology, Uenohara, Yamanashi 409-0913 (Japan); Fujinami, M. [Department of Applied Chemistry, Chiba University, Yayoi, Inage, Chiba, Chiba 263-8552 (Japan)

    2011-07-21

    A practical transmission positron microscope (TPM) JEM-1011B has been developed to survey differences in the interaction of positron and electron beams with materials, and is installed in the Slow Positron Facility of High Energy Accelerator Research Organization (KEK). The TPM can share positron and electron beams, and can also be used as a transmission electron microscope (TEM). Positron transmission images up to magnification 10,000x (resolution: 50 nm) and positron diffraction patterns up to 044 family were successfully obtained by the TPM comparing them with those of electrons. The differences in material transmittances for both beams have been measured, and can be explained by the calculated results of the Monte Carlo simulation code PENELOPE-2008.

  7. Energy variable monoenergetic positron beam study of oxygen atoms in Czochralski grown Si

    International Nuclear Information System (INIS)

    Tanigawa, S.; Wei, L.; Tabuki, Y.; Nagai, R.; Takeda, E.

    1992-01-01

    A monoenergetic positron beam has been used to investigate the state of interstitial oxygen in Czochralski-grown Si with the coverage of SiO 2 (100 nm) and poly-Si (200 nm)/SiO 2 (100 nm), respectively. It was found that (i) the growth of SiO 2 gives rise to a strong Doppler broadening of positron annihilation radiations in the bulk of Si, (ii) such a broadening can be recovered to the original level by annealing at 450degC, by the removal of overlayers using chemical etching and long-term aging at room temperature, (iii) the film stress over the CZ-grown Si is responsible for the rearrangement of oxygen atoms in S and (iv) only tensile stress gives rise to the clustering of oxygen atoms. The observed broadening was assigned to arise from the positron trapping by oxygen interstitial clusters. It was concluded that film stress is responsible for the rearrangement of oxygen atoms in CZ-grown Si. (author)

  8. Positron annihilation microprobe

    Energy Technology Data Exchange (ETDEWEB)

    Canter, K F [Brandeis Univ., Waltham, MA (United States)

    1997-03-01

    Advances in positron annihilation microprobe development are reviewed. The present resolution achievable is 3 {mu}m. The ultimate resolution is expected to be 0.1 {mu}m which will enable the positron microprobe to be a valuable tool in the development of 0.1 {mu}m scale electronic devices in the future. (author)

  9. Positron lifetimes in deformed copper

    International Nuclear Information System (INIS)

    Hinode, Kenji; Tanigawa, Shoichiro; Doyama, Masao

    1976-01-01

    Positron lifetime measurements were performed for Cu samples with different densities of lattice defects. The lifetime spectra were successfully resolved into two components with the help of the well established analysis program. Obtained results were quite consistent with those expected from the trapping model. The positron trapping mechanism from free to trapped states and the initial condition of the model were especially checked. Deduced values obtained for tau sub(c) (lifetime of free positrons) and tau sub(t) (lifetime of trapped positrons) were 122+-5 psec and 176+-5 psec, respectively. (auth.)

  10. Positron annihilation near fractal surfaces

    International Nuclear Information System (INIS)

    Lung, C.W.; Deng, K.M.; Xiong, L.Y.

    1991-07-01

    A model for positron annihilation in the sub-surface region near a fractal surface is proposed. It is found that the power law relationship between the mean positron implantation depth and incident positron energy can be used to measure the fractal dimension of the fractal surface in materials. (author). 10 refs, 2 figs

  11. High energy positron imaging

    International Nuclear Information System (INIS)

    Chen Shengzu

    2003-01-01

    The technique of High Energy Positron Imaging (HEPI) is the new development and extension of Positron Emission Tomography (PET). It consists of High Energy Collimation Imaging (HECI), Dual Head Coincidence Detection Imaging (DHCDI) and Positron Emission Tomography (PET). We describe the history of the development and the basic principle of the imaging methods of HEPI in details in this paper. Finally, the new technique of the imaging fusion, which combined the anatomical image and the functional image together are also introduced briefly

  12. High intensity positron program at LLNL

    International Nuclear Information System (INIS)

    Asoka-Kumar, P.; Howell, R.; Stoeffl, W.; Carter, D.

    1999-01-01

    Lawrence Livermore National Laboratory (LLNL) is the home of the world's highest current beam of keV positrons. The potential for establishing a national center for materials analysis using positron annihilation techniques around this capability is being actively pursued. The high LLNL beam current will enable investigations in several new areas. We are developing a positron microprobe that will produce a pulsed, focused positron beam for 3-dimensional scans of defect size and concentration with submicron resolution. Below we summarize the important design features of this microprobe. Several experimental end stations will be available that can utilize the high current beam with a time distribution determined by the electron linac pulse structure, quasi-continuous, or bunched at 20 MHz, and can operate in an electrostatic or (and) magnetostatic environment. Some of the planned early experiments are: two-dimensional angular correlation of annihilation radiation of thin films and buried interfaces, positron diffraction holography, positron induced desorption, and positron induced Auger spectroscopy

  13. High intensity positron program at LLNL

    International Nuclear Information System (INIS)

    Asoka-Kumar, P.; Howell, R.H.; Stoeffl, W.

    1998-01-01

    Lawrence Livermore National Laboratory (LLNL) is the home of the world's highest current beam of keV positrons. The potential for establishing a national center for materials analysis using positron annihilation techniques around this capability is being actively pursued. The high LLNL beam current will enable investigations in several new areas. We are developing a positron microprobe that will produce a pulsed, focused positron beam for 3-dimensional scans of defect size and concentration with submicron resolution. Below we summarize the important design features of this microprobe. Several experimental end stations will be available that can utilize the high current beam with a time distribution determined by the electron linac pulse structure, quasi-continuous, or bunched at 20 MHz, and can operate in an electrostatic or (and) magnetostatic environment. Some of the planned early experiments are: two-dimensional angular correlation of annihilation radiation of thin films and buried interfaces, positron diffraction holography, positron induced desorption, and positron induced Auger spectra

  14. Positron and positronium annihilation in silica-based thin films studied by a pulsed positron beam

    International Nuclear Information System (INIS)

    Suzuki, R.; Ohdaira, T.; Kobayashi, Y.; Ito, K.; Shioya, Y.; Ishimaru, T.

    2003-01-01

    Positron and positronium annihilation in silica-based thin films has been investigated by means of measurement techniques with a monoenergetic pulsed positron beam. The age-momentum correlation study revealed that positron annihilation in thermally grown SiO 2 is basically the same as that in bulk amorphous SiO 2 while o-Ps in the PECVD grown SiCOH film predominantly annihilate with electrons of C and H at the microvoid surfaces. We also discuss time-dependent three-gamma annihilation in porous low-k films by two-dimensional positron annihilation lifetime spectroscopy

  15. Positron astronomy with SPI/INTEGRAL

    International Nuclear Information System (INIS)

    Weidenspointner, G.; Diehl, R.; Strong, A.; Weidenspointner, G.; Skinner, G.K.; Skinner, G.K.; Jean, P.; Knoedlseder, J.; Von Ballmoos, P.; Cordier, B.; Schanne, S.; Winkler, C.

    2008-01-01

    We provide an overview of positron astronomy results that have been obtained using the INTEGRAL spectrometer SPI, and discuss their implications for the still mysterious origin of positrons in our Galaxy. It has long been known that the 511 keV positron annihilation emission is strongest from the central region of our Galaxy. Recently, it has been discovered with the SPI spectrometer that the weaker 511 keV line emission from the inner Galactic disk appears to be asymmetric, with the emission to the west of the Galactic center being about twice as strong than that to the east. This distribution of positron annihilation resembles that of low mass X-ray binaries as observed with the INTEGRAL imager IBIS at hard X-ray energies, suggesting that these systems could provide a significant portion of the positrons in our Galaxy. In addition, the spectrometer SPI has permitted unprecedented spectroscopy of annihilation radiation from the bulge and disk regions of the Galaxy, which commences to yield important insights into the conditions of the medium in which the positrons annihilate. (authors)

  16. New approaches for a time- and position-resolved detector for positron annihilation spectroscopy at PLEPS

    Energy Technology Data Exchange (ETDEWEB)

    Ackermann, Ulrich; Egger, Werner; Sperr, Peter; Loewe, Benjamin; Ravelli, Luca; Koegel, Gottfried; Dollinger, Guenther [Universitaet der Bundeswehr Muenchen, LRT2 (Germany); Jagutzki, Ottmar [Universitaet Frankfurt, RoentDek GmbH (Germany)

    2013-07-01

    The pulsed low energy positron system PLEPS at NEPOMUC at the FRM II is a tool for depth resolved positron lifetime measurements. Besides positron lifetime measurements 2D-AMOC (two dimensional age momentum correlation) experiments are also possible. 2D-AMOC provides in coincidence the lifetime of the positron and the longitudinal momentum distribution of the annihilating electron. It would be of great scientific concern to measure simultaneously the entire 3D-momentum distribution of the annihilating electron and the corresponding lifetime of the positron (4D-AMOC). To perform 4D-AMOC measurements, a time and spatially resolving detector with a time resolution of about 100 ps (FWHM) and a spatial resolution of circa 2 mm over an area of about 12 cm{sup 2} is required in coincidence with a pixelated Ge-detector and currently under development at our institute. It is intended to use a MCP-based UV-light detector with two MCP-stages coupled to a BaF{sub 2} scintillator. To achieve the spatial resolution the centroid information of the photoelectron-cloud is detected with a position sensitive anode installed outside the housing of the MCP detector. As an alternative to a MCP-based detector, silicon photomultipliers are also envisaged.

  17. Positron implantation profile in kapton

    International Nuclear Information System (INIS)

    Plotkowski, K.; Panek, T.J.; Kansj, J.

    1988-01-01

    Measurements of positrons' implantation profile were made with geometry as in the majority of PAT experiments, making use of the difference in values of mean lifetimes of positrons in the absorber and in the detector. The function describing the absorption of positrons in the absorber taking into account measurement geometry was fitted to the experimental data. The correction to the exponential relation occurring in this function is the dominating factor for small thicknesses of the absorber. In this analysis various values of positrons' backscatter coefficients of the nickel and of the kapton were also taken into account

  18. The Positron-Electron Correlation Energy In ZnO Calculated With The Modified Single Wave Function Of Positron

    International Nuclear Information System (INIS)

    Chau Van Tao; Trinh Hoa Lang; Le Hoang Chien; Nguyen Huu Loc; Nguyen Anh Tuan

    2011-01-01

    Positron-electron correlation energy of the ZnO - positron system is studied on assumption that positron binds with the outer shell electrons of Zinc and Oxygen to form the pseudo ZnO - positron molecule before it annihilates with one of these electrons. In this work, the single wave function for positron is form by LCAO approximation and is modified according to the principle of linear superposition, and by using Variational Quantum Monte Carlo method (VQMC) [7] the correlation energy of this system is estimated with the value E c e-p = - 9.3 ± 1.1 eV. In the theoretical aspect it turns out that this result is more reasonable and closer to those of other methods [3] than the one which is done without modifying the wave function of positron [1]. To confirm this legitimate approach, however, the further calculations of positron annihilation rate in ZnO have to be carried out in our next work. (author)

  19. A Southern African positron beam

    International Nuclear Information System (INIS)

    Britton, D.T.; Haerting, M.; Teemane, M.R.B.; Mills, S.; Nortier, F.M.; Van der Walt, T.N.

    1997-01-01

    The first stage of a state of the art positron beam, being constructed at the University of Cape Town, is currently being brought into operation. This is the first positron beam on the African continent, as well as being the first positron beam dedicated to solid and surface studies in the southern hemisphere. The project also contains a high proportion of local development, including the encapsulated 22 Na positron source developed by our collaboration. Novel features in the design include a purely magnetic in-line deflector, working in the solenoidal guiding field, to eliminate unmoderated positrons and block the direct line of sight to the source. A combined magnetic projector and single pole probe forming lens is being implemented in the second phase of construction to achieve a spot size of 10 μm without remoderation

  20. Positron Transport and Annihilation in the Galactic Bulge

    Directory of Open Access Journals (Sweden)

    Fiona Helen Panther

    2018-03-01

    Full Text Available The annihilation of positrons in the Milky Way Galaxy has been observed for ∼50 years; however, the production sites of these positrons remains hard to identify. The observed morphology of positron annihilation gamma-rays provides information on the annihilation sites of these Galactic positrons. It is understood that the positrons responsible for the annihilation signal originate at MeV energies. The majority of sources of MeV positrons occupy the star-forming thin disk of the Milky Way. If positrons propagate far from their sources, we must develop accurate models of positron propagation through all interstellar medium (ISM phases in order to reveal the currently uncertain origin of these Galactic positrons. On the other hand, if positrons annihilate close to their sources, an alternative source of MeV positrons with a distribution that matches the annihilation morphology must be identified. In this work, I discuss the various models that have been developed to understand the origin of the 511 keV line from the direction of the Galactic bulge, and the propagation of positrons in the ISM.

  1. Positron emission tomography

    International Nuclear Information System (INIS)

    Yamamoto, Y.L.; Thompson, C.J.; Diksic, M.; Meyer, E.; Feindel, W.H.

    1984-01-01

    One of the most exciting new technologies introduced in the last 10 yr is positron emission tomography (PET). PET provides quantitative, three-dimensional images for the study of specific biochemical and physiological processes in the human body. This approach is analogous to quantitative in-vivo autoradiography but has the added advantage of permitting non-invasive in vivo studies. PET scanning requires a small cyclotron to produce short-lived positron emitting isotopes such as oxygen-15, carbon-11, nitrogen-13 and fluorine-18. Proper radiochemical facilities and advanced computer equipment are also needed. Most important, PET requires a multidisciplinary scientific team of physicists, radiochemists, mathematicians, biochemists and physicians. The most recent trends are reviewed in the imaging technology, radiochemistry, methodology and clinical applications of positron emission tomography. (author)

  2. High intensity positron program at LLNL

    International Nuclear Information System (INIS)

    Asoka-Kumar, P.; Howell, R.; Stoeffl, W.; Carter, D.

    1999-01-01

    Lawrence Livermore National Laboratory (LLNL) is the home of the world close-quote s highest current beam of keV positrons. The potential for establishing a national center for materials analysis using positron annihilation techniques around this capability is being actively pursued. The high LLNL beam current will enable investigations in several new areas. We are developing a positron microprobe that will produce a pulsed, focused positron beam for 3-dimensional scans of defect size and concentration with submicron resolution. Below we summarize the important design features of this microprobe. Several experimental end stations will be available that can utilize the high current beam with a time distribution determined by the electron linac pulse structure, quasi-continuous, or bunched at 20 MHz, and can operate in an electrostatic or (and) magnetostatic environment. Some of the planned early experiments are: two-dimensional angular correlation of annihilation radiation of thin films and buried interfaces, positron diffraction holography, positron induced desorption, and positron induced Auger spectroscopy. copyright 1999 American Institute of Physics

  3. PF slow positron source

    International Nuclear Information System (INIS)

    Shirakawa, A.; Enomoto, A.; Kurihara, T.

    1993-01-01

    A new slow-positron source is under construction at the Photon Factory. Positrons are produced by bombarding a tantalum rod with high-energy electrons; they are moderated in multiple tungsten vanes. We report here the present status of this project. (author)

  4. Positron spectroscopy of 2D materials using an advanced high intensity positron beam

    Science.gov (United States)

    McDonald, A.; Chirayath, V.; Lim, Z.; Gladen, R.; Chrysler, M.; Fairchild, A.; Koymen, A.; Weiss, A.

    An advanced high intensity variable energy positron beam(~1eV to 20keV) has been designed, tested and utilized for the first coincidence Doppler broadening (CDB) measurements on 6-8 layers graphene on polycrystalline Cu sample. The system is capable of simultaneous Positron annihilation induced Auger electron Spectroscopy (PAES) and CDB measurements giving it unparalleled sensitivity to chemical structure at external surfaces, interfaces and internal pore surfaces. The system has a 3m flight path up to a micro channel plate (MCP) for the Auger electrons emitted from the sample. This gives a superior energy resolution for PAES. A solid rare gas(Neon) moderator was used for the generation of the monoenergetic positron beam. The positrons were successfully transported to the sample chamber using axial magnetic field generated with a series of Helmholtz coils. We will discuss the PAES and coincidence Doppler broadening measurements on graphene -Cu sample and present an analysis of the gamma spectra which indicates that a fraction of the positrons implanted at energies 7-60eV can become trapped at the graphene/metal interface. This work was supported by NSF Grant No. DMR 1508719 and DMR 1338130.

  5. Geneva University - The AX-PET experiment : A demonstrator for an axial Positron Emission Tomography

    CERN Multimedia

    Université de Genève

    2012-01-01

    Geneva University École de physique Département de physique nucléaire et corspusculaire 24, quai Ernest-Ansermet 1211 Genève 4 Tél.: (022) 379 62 73 Fax: (022) 379 69 92   Wednesday 14 March 2012 SEMINAIRE DE PHYSIQUE CORPUSCULAIRE 11.15 a.m. - Science II, Auditoire 1S081, 30, quai Ernest-Ansermet, 1211 Genève 4 The AX-PET experiment : A demonstrator for an axial Positron Emission Tomography Dr Chiara CASELLA   ETH Zurich   PET (Positron Emission Tomography) is a tool for in-vivo functional imaging, successfully used since the earliest days of nuclear medicine. It is based on the detection of the two coincident 511 keV photons from the annihilation of a positron, emitted from a radiotracer injected into the body. Tomographic analysis of the coincidence data allows for a 3D reconstructed image of the source distribution. The AX-PET experiment proposes a novel geometrical approach for a PET scanner, in which l...

  6. Positron depth profiling

    International Nuclear Information System (INIS)

    Coleman, P.

    2001-01-01

    Wide-ranging studies of defects below the surface of semiconductor structures have been performed at the University of Bath, in collaboration with the University of Surrey Centre for Ion Beam Applications and with members of research teams at a number of UK universities. Positron implantation has been used in conjunction with other spectroscopies such as RBS-channeling and SIMS, and electrical characterisation methods. Research has ranged from the development of a positron-based technique to monitor the in situ annealing of near-surface open-volume defects to the provision of information on defects to comprehensive diagnostic investigations of specific device structures. We have studied Si primarily but not exclusively; e.g., we have investigated ion-implanted SiC and SiO 2 /GaAs structures. Of particular interest are the applications of positron annihilation spectroscopy to ion-implanted semiconductors, where by linking ion dose to vacancy-type defect concentration one can obtain information on ion dose and uniformity with a sensitivity not achievable by standard techniques. A compact, user-friendly positron beam system is currently being developed at Bath, in collaboration with SCRIBA, with the intention of application in an industrial environment. (orig.)

  7. Positron annihilation induced Auger electron spectroscopy and its implementation at accelerator based low energy positron factories

    International Nuclear Information System (INIS)

    Weiss, A.; Koeymen, A.R.; Mehl, D.; Lee, K.H.; Yang Gimo; Jensen, K.

    1991-01-01

    Positron annihilation induced auger electron spectroscopy (PAES) makes use of a beam of low energy positrons to excite Auger transitions by annihilating core electrons. The large secondary electron background usually present in Auger spectra can be eliminated by setting the positron beam energy well below the Auger electron energy. This allows true Auger lineshapes to be obtained. Further, because the positron is localized just outside the surface before it annihilates, PAES is extremely sensitive to the topmost atomic layer. Recent PAES results obtained at the University of Texas at Arlington will be presented. In addition, the use of high resolution energy analyzers with multichannel particle detection schemes to prevent problems due to the high data rates associated with accelerator based positron beams will be discussed. (orig.)

  8. Nonlinear positron acoustic solitary waves

    International Nuclear Information System (INIS)

    Tribeche, Mouloud; Aoutou, Kamel; Younsi, Smain; Amour, Rabia

    2009-01-01

    The problem of nonlinear positron acoustic solitary waves involving the dynamics of mobile cold positrons is addressed. A theoretical work is presented to show their existence and possible realization in a simple four-component plasma model. The results should be useful for the understanding of the localized structures that may occur in space and laboratory plasmas as new sources of cold positrons are now well developed.

  9. Positron emission tomography. Basic principles

    International Nuclear Information System (INIS)

    Rodriguez, Jose Luis; Massardo, Teresa; Gonzalez, Patricio

    2001-01-01

    The basic principles of positron emission tomography (PET) technique are reviewed. lt allows to obtain functional images from gamma rays produced by annihilation of a positron, a positive beta particle. This paper analyzes positron emitters production in a cyclotron, its general mechanisms, and the various detection systems. The most important clinical applications are also mentioned, related to oncological uses of fluor-l8-deoxyglucose

  10. Compressive effect of the magnetic field on the positron range in commonly used positron emitters simulated using Geant4

    Science.gov (United States)

    Li, Chong; Cao, Xingzhong; Liu, Fuyan; Tang, Haohui; Zhang, Zhiming; Wang, Baoyi; Wei, Long

    2017-11-01

    The compressive effect of a magnetic field on the positron range from commonly used positron emitters in PET (Positron Emission Tomography) was simulated using the Geant4 toolkit with H2O as the environmental material. The compression of the positron range, which was different in the directions parallel and perpendicular to the magnetic field, showed finite final variation of relative change rate versus the magnetic field. The variation greatly depended on the positron-emission energy spectrum in the same medium. Furthermore, the volume of the positron annihilation point was dramatically compressed as the magnetic field was set in the range of 3-6T. It was more prominent for 82Rb , which is generally used as a positron source in PET technology.

  11. Positron annihilation studies of mesoporous silica films using a slow positron beam

    International Nuclear Information System (INIS)

    He Chunqing; Muramatsu, Makoto; Ohdaira, Toshiyuki; Kinomura, Atsushi; Suzuki, Ryoichi; Ito, Kenji; Kabayashi, Yoshinori

    2006-01-01

    Positron annihilation lifetime spectra were measured for mesoporous silica films, which were synthesized using triblock copolymer (EO 106 PO 70 EO 106 ) as a structure-directing agent. Different positron lifetime spectra for the deposited and calcined films indicated the formation of meso-structure after calcination, which was confirmed by Fourier transform infrared (FTIR) spectra and field emission-scanning electron microscopy (FE-SEM) observation. Open porosity or pore interconnectivity of a silica film might be evaluated by a two-dimensional positron annihilation lifetime spectrum of an uncapped film. Pore sizes and their distributions in the silica films were found to be affected by thermal treatments

  12. Positron annihilation spectroscopy

    International Nuclear Information System (INIS)

    Sundar, C.S.; Viswanathan, B.

    1996-01-01

    An overview of positron annihilation spectroscopy, the experimental techniques and its application to studies on defects and electronic structure of materials is presented. The scope of this paper is to present the requisite introductory material, that will enable a better appreciation of the subsequent specialized articles on the applications of positron annihilation spectroscopy to investigate various problems in materials science. (author). 31 refs., 3 figs

  13. Positron Studies of Oxide-Semiconductor Structures

    OpenAIRE

    Uedono , A.; Wei , L.; Kawano , T.; Tanigawa , S.; Suzuki , R.; Ohgaki , H.; Mikado , T.

    1995-01-01

    The annihilation characteristics of positrons in SiO2 films grown on Si substrates were studied by using monoenergetic positron beams. Doppler broadening profiles of the annihilation radiation and lifetime spectra of positrons were measured as a function of incident positron energy for SiO2/Si structures fabricated by various oxidation techniques. From the measurements, it was found that the formation probability of positronium (Ps) atoms in SiO2 films strongly depends on the growth condition...

  14. Depth-dependent positron annihilation in different polymers

    Energy Technology Data Exchange (ETDEWEB)

    Yang, J.; Zhang, P.; Cheng, G.D.; Li, D.X.; Wu, H.B.; Li, Z.X.; Cao, X.Z. [Key Laboratory of Nuclear Analysis Techniques, Institute of High Energy Physics, Chinese Academy of Sciences, No. 19 Yuquan Lu, Beijing 100049 (China); Jia, Q.J. [Beijing Synchrotron Radiation Facility, Institute of High Energy Physics, Chinese Academy of Sciences, No. 19 Yuquan Lu, Beijing 100049 (China); Yu, R.S. [Key Laboratory of Nuclear Analysis Techniques, Institute of High Energy Physics, Chinese Academy of Sciences, No. 19 Yuquan Lu, Beijing 100049 (China); Wang, B.Y., E-mail: wangboy@ihep.ac.cn [Key Laboratory of Nuclear Analysis Techniques, Institute of High Energy Physics, Chinese Academy of Sciences, No. 19 Yuquan Lu, Beijing 100049 (China)

    2013-09-01

    Depth-dependent positron annihilation Doppler broadening measurements were conducted for polymers with different chemical compositions. Variations of the S parameter with respect to incident positron energy were observed. For pure hydrocarbons PP, HDPE and oxygen-containing polymer PC, S parameter rises with increasing positron implantation depth. While for PI and fluoropolymers like PTFE, ETFE and PVF, S parameter decreases with higher positron energy. For chlorine-containing polymer PVDC, S parameter remains nearly constant at all incident positron energies. It is suggested that these three variation trends are resulted from a competitive effect between the depth-dependent positronium formation and the influence of highly electronegative atoms on positron annihilation characteristics.

  15. Simulation of the annihilation emission of galactic positrons; Modelisation de l'emission d'annihilation des positrons Galactiques

    Energy Technology Data Exchange (ETDEWEB)

    Gillard, W

    2008-01-15

    Positrons annihilate in the central region of our Galaxy. This has been known since the detection of a strong emission line centered on an energy of 511 keV in the direction of the Galactic center. This gamma-ray line is emitted during the annihilation of positrons with electrons from the interstellar medium. The spectrometer SPI, onboard the INTEGRAL observatory, performed spatial and spectral analyses of the positron annihilation emission. This thesis presents a study of the Galactic positron annihilation emission based on models of the different interactions undergone by positrons in the interstellar medium. The models are relied on our present knowledge of the properties of the interstellar medium in the Galactic bulge, where most of the positrons annihilate, and of the physics of positrons (production, propagation and annihilation processes). In order to obtain constraints on the positrons sources and physical characteristics of the annihilation medium, we compared the results of the models to measurements provided by the SPI spectrometer. (author)

  16. Experimentation with low-energy positron beams

    International Nuclear Information System (INIS)

    Mills, A.P. Jr.

    1983-01-01

    The capability of studying the interactions of positrons with surfaces has recently been exploited by using ultra-high-vacuum techniques. The result has been a new understanding of how positrons interact with surfaces and because of this we are now able to make much stronger fluxes of slow positrons. The higher beam strengths in turn are opening up new possibilities for experimentation on surfaces and solids and for studying the atomic physics of positronium and positron-molecule scattering at low energies. The lectures are intended to review some of the history of this subject and to outline the present state of our knowledge of experimentation with low-energy positron beams. (orig./TW)

  17. Positron annihilation in vitreous silica glasses

    International Nuclear Information System (INIS)

    Uedono, Akira; Tanigawa, Shoichiro

    1993-01-01

    The annihilation characteristics of positrons in vitreous silica glasses (v-SiO 2 ) were studied by measurements of two-dimensional angular correlation of positron annihilation radiations and positron lifetime spectra. From the measurements, it was found that positrons and positronium (Ps) atoms mainly annihilate from trapped states by vacancy-type defects in v-SiO 2 . For v-SiO 2 specimens with cylindrical porous structures, annihilations of Ps with anisotropic momentum distributions were observed. This fact was attributed to the momentum uncertainty due to localization of Ps in a finite dimension of pores. This investigation showed possibilities for the detection of microstructures in v-SiO 2 by the positron annihilation technique. (author)

  18. Positrons in ionic crystals

    International Nuclear Information System (INIS)

    Pareja, R.

    1988-01-01

    Positron annihilation experiments in ionic crystals are reviewed and their results are arranged. A discussion about the positron states in these materials is made in the light of these results and the different proposed models. The positronium in alkali halides is specially considered. (Author)

  19. Positron annihilation in SiO 2-Si studied by a pulsed slow positron beam

    Science.gov (United States)

    Suzuki, R.; Ohdaira, T.; Uedono, A.; Kobayashi, Y.

    2002-06-01

    Positron and positronium (Ps) behavior in SiO 2-Si have been studied by means of positron annihilation lifetime spectroscopy (PALS) and age-momentum correlation (AMOC) spectroscopy with a pulsed slow positron beam. The PALS study of SiO 2-Si samples, which were prepared by a dry-oxygen thermal process, revealed that the positrons implanted in the Si substrate and diffused back to the interface do not contribute to the ortho-Ps long-lived component, and the lifetime spectrum of the interface has at least two components. From the AMOC study, the momentum distribution of the ortho-Ps pick-off annihilation in SiO 2, which shows broader momentum distribution than that of crystalline Si, was found to be almost the same as that of free positron annihilation in SiO 2. A varied interface model was proposed to interpret the results of the metal-oxide-semiconductor (MOS) experiments. The narrow momentum distribution found in the n-type MOS with a negative gate bias voltage could be attributed to Ps formation and rapid spin exchange in the SiO 2-Si interface. We have developed a two-dimensional positron lifetime technique, which measures annihilation time and pulse height of the scintillation gamma-ray detector for each event. Using this technique, the positronium behavior in a porous SiO 2 film, grown by a sputtering method, has been studied.

  20. Theoretical calculations of positron lifetimes for metal oxides

    International Nuclear Information System (INIS)

    Mizuno, Masataka; Araki, Hideki; Shirai, Yasuharu

    2004-01-01

    Our recent positron lifetime measurements for metal oxides suggest that positron lifetimes of bulk state in metal oxides are shorter than previously reported values. We have performed theoretical calculations of positron lifetimes for bulk and vacancy states in MgO and ZnO using first-principles electronic structure calculations and discuss the validity of positron lifetime calculations for insulators. By comparing the calculated positron lifetimes to the experimental values, it wa found that the semiconductor model well reproduces the experimental positron lifetime. The longer positron lifetime previously reported can be considered to arise from not only the bulk but also from the vacancy induced by impurities. In the case of cation vacancy, the calculated positron lifetime based on semiconductor model is shorter than the experimental value, which suggests that the inward relaxation occurs around the cation vacancy trapping the positron. (author)

  1. Production and applications of positron microbeams

    International Nuclear Information System (INIS)

    Brandes, G.R.; Canter, K.F.; Horsky, T.N.; Lippel, P.H.; Mills, A.P. Jr.

    1989-01-01

    The production of a positron microbeam using the high-brightness beam developed at Brandeis University and possible applications of this microbeam to spatially resolved defect studies and positron microscopy are reviewed. The high-brightness beam consists of a W(110) primary moderator and two remoderation stages which provide a 500-fold increase in brightness. With this brightness increase and microbeam optics, we are able to form a 12 μm FWHM beam (48 mrad pencil half-angle) at 5 keV beam energy. The well characterised small-diameter beam is particularly adaptable for determining defect concentration and structure, both laterally and in a depth-profiling mode. In the case of a transmission positron microscope or a positron re-emission microscope operating in a high-magnification mode, efficient image formation requires the use of a microbeam to maximise the number of positrons in the area being imaged. Results of the scanning microbeam tests and the application of a microbeam to positron microscopy and defect studies are reviewed. (author)

  2. Detection of tokamak plasma positrons using annihilation photons

    Energy Technology Data Exchange (ETDEWEB)

    Guanying, Yu; Liu, Jian; Xie, Jinlin [University of Science and Technology, Hefei, Anhui, 230027 (China); Li, Jiangang, E-mail: j_li@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui 230031 (China)

    2017-05-15

    Highlights: • A design for detection of tokamak plasma positrons is given. • Identify the main obstacle toward experimental confirmation of fusion plasma positrons. • Signal to noise ratio in a plasma disruption is estimated. • Unique potential applications of fusion plasma positrons are discussed. - Abstract: A massive amount of positrons (plasma positrons), produced by the collision between runaway electrons and nuclei during fusion plasma disruption, was first predicted theoretically in 2003. To help confirm this prediction, we report here the design of an experimental system to detect tokamak plasma positrons. Because a substantial amount of positrons (material positrons) are produced when runaway electrons impact plasma-facing materials, we proposed maximizing the ratio of plasma to material positrons by inserting a thin carbon target at the plasma edge as a plasma positron bombing target and producing a plasma disruption scenario triggered by massive gas injection. Meanwhile, the coincidence detection of positron annihilation photons was used to filter out the noise of annihilation photons from locations other than the carbon target and that of bremsstrahlung photons near 511 keV. According to our simulation, the overall signal-to-noise ratio should be more than 10:1.

  3. Time-dependent behavior of positrons in noble gases

    International Nuclear Information System (INIS)

    Wadehra, J.M.

    1990-01-01

    Both equilibrium and nonequilibrium behaviors of positrons in several noble gases are reviewed. Our novel procedure for obtaining the time-dependent behavior of various swarm parameters -- such as the positron drift velocity, average positron energy, positron annihilation rate (or equivalently Z eff ) etc. -- for positrons in pure ambient gases subjected to external electrostatic fields is described. Summaries of time-dependent as well as electric field-dependent results for positron swarms in various noble gases are presented. New time-dependent results for positron swarms in neon are also described in detail. 36 refs., 4 figs., 3 tabs

  4. Radiation damage of polymers studied by positron annihilation. Positron and gamma-ray irradiation effects

    International Nuclear Information System (INIS)

    Suzuki, T.; Oki, Y.; Numajiri, M.; Miura, T.; Kondo, K.; Ito, Y.

    1995-01-01

    Positron irradiation effects on polypropylene (PP) have been studied using positron sources ( 22 Na) during positron annihilation (PA) experiments. The irradiation effect was measured by the intensity (I 3 ) of the long-lived component of positronium (Ps). At a low temperature of around 100 K, I 3 for unirradiated PP samples increased due to a termination of the thermal motion of the -CH 3 groups. However, the increase in I 3 for γ-ray irradiated samples was reduced in inverse proportion to the amount of irradiation. Although no increase in I 3 was observed for 1 MGy-irradiated PP with γ-rays, an increase was observed again after a 48 h irradiation by positrons emitted from 22 Na. This may be due to a reconstructing of the polymer chains. (author)

  5. PEP-II Alignment

    CERN Document Server

    Gaydosh, M

    2003-01-01

    The PEP-II Asymmetric B-factory consists of two independent storage rings, one located atop the other in the 2200m-circumference PEP tunnel. The high-energy ring, which stores a 9-GeV electron beam, is an upgrade of the existing PEP collider. It re-utilizes all of the PEP magnets and incorporates a state-of-the-art copper vacuum chamber and a new RF system capable of supporting a one-amp stored beam. The low-energy ring, which stores 3.1-GeV positrons, is new construction. Injection is achieved by extracting electrons and positrons at collision energies from the SLC and transporting them each in a dedicated bypass line. The low-emittance SLC beams will be used for the injection process.

  6. Effects of positron density and temperature on large amplitude ion-acoustic waves in an electron-positron-ion plasma

    International Nuclear Information System (INIS)

    Nejoh, Y.N.

    1997-01-01

    The nonlinear wave structures of large amplitude ion-acoustic waves are studied in a plasma with positrons. We have presented the region of existence of the ion-acoustic waves by analysing the structure of the pseudopotential. The region of existence sensitively depends on the positron to electron density ratio, the ion to electron mass ratio and the positron to electron temperature ratio. It is shown that the maximum Mach number increases as the positron temperature increases and the region of existence of the ion-acoustic waves spreads as the positron temperature increases. 12 refs., 6 figs

  7. Importance of non-local electron-positron correlations for positron annihilation characteristics in solids

    International Nuclear Information System (INIS)

    Rubaszek, A.

    2001-01-01

    Several methods to describe the electron-positron (e-p) correlation effects are used in calculations of positron annihilation characteristics in solids. The weighted density approximation (WDA), giving rise to the non-local, state-selective e-p correlation functions, is applied to calculate positron annihilation rates and e-p momentum densities in a variety of metals and silicon. The WDA results are compared to the results of other methods such as the independent particle model, local density approximation, generalised gradient approximation, and also to experiments. The importance of non-locality and state-dependence of the e-p correlation functions is discussed. (orig.)

  8. Positron source based on the 48V isotope dedicated to positron lifetime spectroscopy

    International Nuclear Information System (INIS)

    Dryzek, Jerzy

    2009-01-01

    In the paper we consider application of the 48 V isotope as a source in the positron lifetime spectroscopy. The isotope was produced in the 48 Ti(p,n) 48 V reaction using 15 MeV proton beam. As a target the natural titanium thin plate was used. The measurements using the typical positron lifetime spectrometer have shown the usefulness of the source obtained for this application. Due to its properties, the source may be used for measurements of positron annihilation characteristics in high temperature or aggressive environments. (copyright 2009 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  9. Applications of positron depth profiling

    Energy Technology Data Exchange (ETDEWEB)

    Hakvoort, R A

    1993-12-23

    In this thesis some contributions of the positron-depth profiling technique to materials science have been described. Following studies are carried out: Positron-annihilation measurements on neon-implanted steel; Void creation in silicon by helium implantation; Density of vacancy-type defects present in amorphous silicon prepared by ion implantation; Measurements of other types of amorphous silicon; Epitaxial cobalt disilicide prepared by cobalt outdiffusion. Positron-annihilation experiments on low-pressure CVD silicon-nitride films. (orig./MM).

  10. Applications of positron depth profiling

    International Nuclear Information System (INIS)

    Hakvoort, R.A.

    1993-01-01

    In this thesis some contributions of the positron-depth profiling technique to materials science have been described. Following studies are carried out: Positron-annihilation measurements on neon-implanted steel; Void creation in silicon by helium implantation; Density of vacancy-type defects present in amorphous silicon prepared by ion implantation; Measurements of other types of amorphous silicon; Epitaxial cobalt disilicide prepared by cobalt outdiffusion. Positron-annihilation experiments on low-pressure CVD silicon-nitride films. (orig./MM)

  11. Positron emission tomography

    International Nuclear Information System (INIS)

    Lindback, Stig

    1995-01-01

    Positron Emission Tomography (PET) is an advanced nuclear medicine technique used for research at major centres. Unique diagnostic information is obtained from tomographic measurements of the biochemistry and physiology of tissues and organs. In theory, diseases are related to biochemical changes and these can be observed with PET long before any anatomical changes are detectable. In PET the radioactive component is a positron-emitting isotope or 'tracer'. The positrons annihilate with electrons in the body to produce two gamma rays 180° apart; coincidence detection of these gammas provides a very efficient method of determining the spatial distribution of the radioisotope tracer. Because physiological measurements are usually required in a single imaging session, very short-lived isotopes are used to label the tracer molecules; isotope production and labelling is usually carried out in situ. The most commonly used radionuclides are carbon- 11 (half-life 20 minutes), nitrogen-13 (10 minutes), oxygen-15 (2 minutes), and fluorine-18 (110 minutes). A PET system has three major components: - a particle accelerator with targets for production of the positron-emitting isotopes; - chemistry modules for synthesis and labelling of the desired tracers; - and a PET camera for in-vivo measurements of the distribution of the tracer in the body

  12. Positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lindback, Stig [GEMS PET Systems AB, Uppsala (Sweden)

    1995-07-15

    Positron Emission Tomography (PET) is an advanced nuclear medicine technique used for research at major centres. Unique diagnostic information is obtained from tomographic measurements of the biochemistry and physiology of tissues and organs. In theory, diseases are related to biochemical changes and these can be observed with PET long before any anatomical changes are detectable. In PET the radioactive component is a positron-emitting isotope or 'tracer'. The positrons annihilate with electrons in the body to produce two gamma rays 180° apart; coincidence detection of these gammas provides a very efficient method of determining the spatial distribution of the radioisotope tracer. Because physiological measurements are usually required in a single imaging session, very short-lived isotopes are used to label the tracer molecules; isotope production and labelling is usually carried out in situ. The most commonly used radionuclides are carbon- 11 (half-life 20 minutes), nitrogen-13 (10 minutes), oxygen-15 (2 minutes), and fluorine-18 (110 minutes). A PET system has three major components: - a particle accelerator with targets for production of the positron-emitting isotopes; - chemistry modules for synthesis and labelling of the desired tracers; - and a PET camera for in-vivo measurements of the distribution of the tracer in the body.

  13. Positron probes of the Ge(1 0 0) surface: The effects of surface reconstructions and electron-positron correlations on positron trapping and annihilation characteristics

    International Nuclear Information System (INIS)

    Fazleev, N.G.; Jung, E.; Weiss, A.H.

    2007-01-01

    Positron annihilation induced Auger electron spectroscopy (PAES) has been applied to study the Ge(1 0 0) surface. The high-resolution PAES spectrum from the Ge(1 0 0) surface displays several strong Auger peaks corresponding to M 4,5 N 1 N 2,3 , M 2,3 M 4,5 M 4,5 , M 2,3 M 4,5 V and M 1 M 4,5 M 4,5 Auger transitions. The integrated peak intensities of Auger transitions are used to obtain experimental annihilation probabilities for the Ge 3d and 3p core level electrons. These experimental results are analyzed by performing calculations of positron surface states and annihilation characteristics of surface trapped positrons with relevant Ge core-level electrons for the non-reconstructed and reconstructed Ge(1 0 0)-p(2 x 1), Ge(1 0 0)-p(2 x 2) and Ge(1 0 0)-c(4 x 2) surfaces. It is found that the positron surface state wave function extends into the Ge lattice in the regions where atoms are displaced from their ideal terminated positions due to reconstructions. Estimates of the positron binding energy and the positron annihilation characteristics reveal their sensitivity to the specific atomic structure of the topmost layers of Ge(1 0 0). A comparison with PAES data reveals an agreement with theoretical core annihilation probabilities for the Auger transitions considered

  14. The cryogenic source of slow monochromatic positrons

    International Nuclear Information System (INIS)

    Meshkov, I.N.; Pavlov, V.N.; Sidorin, A.O.; Yakovenko, S.L.

    2008-01-01

    The cryogenic source of slow monochromatic positrons based on the 22 Na isotope has been designed and constructed at JINR. Positrons emitted from radioactive source 22 Na have a very broad energy spectrum up to 0.5 MeV. To generate monochromatic beam of slow positrons the solid neon is used as a moderator. The solid neon allows forming slow positron beam of the energy of 1.2 eV at the spectrum width of 1 eV. The efficiency of moderation is 1 % of total positron flux

  15. Pep for PEP-II

    International Nuclear Information System (INIS)

    Anon.

    1995-01-01

    The major B-factory project at the Stanford Linear Accelerator Center have(SLAC) is well underway and moving along smartly, en route to commencement of operations in September 1998. Called PEP-II, the new facility is a joint venture of three California laboratories: Lawrence Berkeley Laboratory (LBL), Lawrence Livermore Laboratory (LLNL) and SLAC. Housed at SLAC in the tunnels and buildings built for the original PEP electron-positron collider in the late 1970s, it involves no conventional civil engineering. In fact, PEP-II is a recycling project in more ways than one: for example, most of the original PEP magnets have been renovated for reuse in the PEP-II high-energy ring. While some of them require substantial rework (to change their length, for instance), many of them merely require repainting and remeasuring. The work of building the hardware is divided up among the three laboratories. LBL is primarily responsible for the low-energy ring; LLNL is building most of the interaction region, the complicated part where the high and low energy rings come together; and SLAC is responsible for the rest. Proposed by President Clinton as a ''presidential initiative'' (December 1993, page 2), the project was given a four-year funding profile. The total cost of $177 million, excluding the BaBar detector (September, page 16), was planned by the US government to be entirely provided during the present administration, the last increment coming in the final quarter of 1997. Happily, the first two increments have been forthcoming as planned and the third is faring well in US Congress. The PEP-II design is based on two intersecting storage rings, one carrying 9 GeV electrons and the other 3.1 GeV positrons, operating with high beam currents (a few amperes) to produce a luminosity of 3 x 10 33 per sq cm per s. The asymmetry in the energies of the colliding particles means that the centre-ofmass of the electron-positron annihilation system moves rapidly in the

  16. Probing the positron moderation process using high-intensity, highly polarized slow-positron beams

    Science.gov (United States)

    Van House, J.; Zitzewitz, P. W.

    1984-01-01

    A highly polarized (P = 0.48 + or - 0.02) intense (500,000/sec) beam of 'slow' (Delta E = about 2 eV) positrons (e+) is generated, and it is shown that it is possible to achieve polarization as high as P = 0.69 + or - 0.04 with reduced intensity. The measured polarization of the slow e+ emitted by five different positron moderators showed no dependence on the moderator atomic number (Z). It is concluded that only source positrons with final kinetic energy below 17 keV contribute to the slow-e+ beam, in disagreement with recent yield functions derived from low-energy measurements. Measurements of polarization and yield with absorbers of different Z between the source and moderator show the effects of the energy and angular distributions of the source positrons on P. The depolarization of fast e+ transmitted through high-Z absorbers has been measured. Applications of polarized slow-e+ beams are discussed.

  17. High efficiency positron moderation

    International Nuclear Information System (INIS)

    Taqqu, D.

    1990-01-01

    A new positron moderation scheme is proposed. It makes use of electric and magnetic fields to confine the β + emitted by a radioactive source forcing them to slow down within a thin foil. A specific arrangement is described where an intermediary slowed-down beam of energy below 10 keV is produced. By directing it towards a standard moderator optimal conversion into slow positrons is achieved. This scheme is best applied to short lived β + emitters for which a 25% moderation efficiency can be reached. Within the state of the art technology a slow positron source intensity exceeding 2 x 10 10 e + /sec is achievable. (orig.)

  18. Positron emission tomography

    International Nuclear Information System (INIS)

    Chandrasekhar, Preethi; Himabindu, Pucha

    2000-01-01

    Positron Emission Tomography (PET) is a non-invasive nuclear imaging technique used to study different molecular pathways and anatomical structures. PET has found extensive applications in various fields of medicine viz. cardiology, oncology, psychiatry/psychology, neuro science and pulmonology. This study paper basically deals with the physics, chemistry and biology behind the PET technique. It discusses the methodology for generation of the radiotracers responsible for emission of positrons and the annihilation and detection techniques. (author)

  19. Positron emission tomography

    International Nuclear Information System (INIS)

    Dvorak, O.

    1989-01-01

    The principle is briefly described of positron emission tomography, and its benefits and constraints are listed. It is emphasized that positron emission tomography (PET) provides valuable information on metabolic changes in the organism that are otherwise only very difficult to obtain, such as brain diagnosis including relationships between mental disorders and the physiology and pathophysiology of the brain. A PET machine is to be installed in Czechoslovakia in the near future. (L.O.)

  20. Relevance of slow positron beam research to astrophysical studies of positron interactions and annihilation in the interstellar medium

    International Nuclear Information System (INIS)

    Guessoum, N.; Jean, P.; Gillard, W.

    2006-01-01

    The processes undergone by positrons in the interstellar medium (ISM) from the moments of their birth to their annihilation are examined. Both the physics of the positron interactions with gases and solids (dust grains), and the physical conditions and characteristics of the environments where the processes of energy loss, positronium formation, and annihilation taking place, are reviewed. An explanation is given as to how all the relevant physical information are taken into account in order to calculate annihilation rates and spectra of the 511 keV emission for the various phases of the ISM; special attention is paid to positron interactions with dust and with polycyclic aromatic hydrocarbons. An attempt is made to show to what extent the interactions between positrons and interstellar dust grains are similar to laboratory experiments in which beams of slow positrons impinge upon solids and surfaces. Sample results are shown for the effect of dust grains on positron annihilation spectra in some phases of the ISM which, together with high resolution spectra measured by satellites, can be used to infer useful knowledge about the environment where the annihilation is predominantly taking place and ultimately about the birth place and history of positrons in the Galaxy. The important complementarity between work done by the astrophysical and the solid-state positron communities is strongly emphasized and specific experimental work is suggested which could assist the modeling of the interaction and annihilation of positrons in the ISM

  1. Relevance of slow positron beam research to astrophysical studies of positron interactions and annihilation in the interstellar medium

    Energy Technology Data Exchange (ETDEWEB)

    Guessoum, N. [American University of Sharjah, Physics Department, P.O. Box 26666, Sharjah (United Arab Emirates)]. E-mail: nguessoum@aus.ac.ae; Jean, P. [Centre d' Etude Spatiale des Rayonnements, Toulouse (France); Gillard, W. [Centre d' Etude Spatiale des Rayonnements, Toulouse (France)

    2006-02-28

    The processes undergone by positrons in the interstellar medium (ISM) from the moments of their birth to their annihilation are examined. Both the physics of the positron interactions with gases and solids (dust grains), and the physical conditions and characteristics of the environments where the processes of energy loss, positronium formation, and annihilation taking place, are reviewed. An explanation is given as to how all the relevant physical information are taken into account in order to calculate annihilation rates and spectra of the 511 keV emission for the various phases of the ISM; special attention is paid to positron interactions with dust and with polycyclic aromatic hydrocarbons. An attempt is made to show to what extent the interactions between positrons and interstellar dust grains are similar to laboratory experiments in which beams of slow positrons impinge upon solids and surfaces. Sample results are shown for the effect of dust grains on positron annihilation spectra in some phases of the ISM which, together with high resolution spectra measured by satellites, can be used to infer useful knowledge about the environment where the annihilation is predominantly taking place and ultimately about the birth place and history of positrons in the Galaxy. The important complementarity between work done by the astrophysical and the solid-state positron communities is strongly emphasized and specific experimental work is suggested which could assist the modeling of the interaction and annihilation of positrons in the ISM.

  2. Three dimensional positron-CT: 3D-PET

    International Nuclear Information System (INIS)

    Ishii, K.

    2000-01-01

    Positron-CT, namely the positron emission tomograph (PET) provides us the metabolism images obtained by the administration of the drug labeled by the positron emission nuclide in the human body. For example, the carbohydrate metabolism image is obtained by the administration of glucose labelled by 18 F-radioisotopes, and it can be applied to early detection of the cancer and research of high-order function of the brain. As well as X-ray CT, the examine receives the exposure in the positron CT. 3D-PET is based on the solid measurement of γ-rays, therefore, the detection sensitivity of 3D-PET becomes very high and it is possible to drastically reduce the dose of the positron emission nuclide. Because the exposure is reduced to the utmost, the positron CT diagnosis would be possible for the child and the exposure of positron CT doctor in charge can be also reduced. This ideal functional diagnostic imaging equipment, namely, 3D-PET is introduced here. (author)

  3. Positron lifetime technique with applications in materials science

    International Nuclear Information System (INIS)

    Vries, J. de.

    1987-01-01

    This thesis deals with the positron lifetime technique as a method to measure extremely low concentrations of extremely small cavities in materials. The method is based upon the fact that the positron lieftime decreases as the electron density increases and upon the fact that a positron preferably annihilates in cavity-like defects in lattices. The theory of positron behaviour in materials and technical aspects of measuring positron liefetimes are described in ch.'s 2 and 3 respectively. Three methods for increasing the time resolution are discussed and some positron sources are described (ch.4). Some applications of the positron lifetime technique and experimental results are shown in chapter 5. 125 refs.; 61 figs.; 18 tabs

  4. Results on positron diffusion in Si

    International Nuclear Information System (INIS)

    Nielsen, B.; Lynn, K.G.; Vehanen, A.; Schultz, P.J.

    1984-10-01

    Positron diffusion in Si(100) and Si(111) has been measured using a variable energy positron beam. The diffusion related parameter, E 0 is found to be 4.2 +- 0.2 keV, significantly longer than previously reported values. The positron diffusion coefficient is estimated at D/sub +/ = 2.3 +- 0.4 cm 2 /sec, the uncertainty arising mainly from the characteristics of the assumed positron implantation profile. A drastic reduction in E 0 is found after heating the sample to 1300 0 K, showing that previously reported low values of E 0 are associated with the thermal history of the sample. A high sensitivity to defects introduced by low energy ion bombardment is found, and the defect recovery was followed during heat treatments. Reconstruction of the Si(111) surface into the so-called 7 x 7 structure had no detectable influence on the positron diffusion behavior. No changes in the positron diffusion was observed after covering the surface with atomic hydrogen. However the yield of positronium formation at the surface was enhanced, attributed to an increased density of states at the surface

  5. Positrons from supernova and the origin of the galactic-center positron-annihilation radiation

    International Nuclear Information System (INIS)

    Colgate, S.A.

    1983-01-01

    The emission of positrons from supernova ejecta is dicussed in terms of the galactic-center annihilation radiation. The positrons from the radioactive sequences 56 Ni→ 56 Co→ 56 Fe are the most numerous source from supernova. Only type I supernova will allow a significant fraction to escape the expanding ejecta. For a neutron star model of a type I SN a fraction 4 x 10 -3 of the escaped positron is enough to create the observed several year fluctuation of the annihilation radiation. The likelihood of this model is discussed in terms of other astrophysical evidence as well as the type I SN light curve

  6. Theoretical aspects of positrons in imperfect solids

    International Nuclear Information System (INIS)

    Puska, M.J.

    1987-01-01

    The efficient use of positron annihilation in defect studies requires a deep understanding of the basic processes of positron-imperfect solid interaction. Three stages, i.e. thermalization, trapping by a defect, and the annihilation can be separated during the evolution of the interaction. The last two processes are the most relevant ones for the positron lifetime spectroscopy and they will be discussed in detail in this review. The complete solution of the problem of a localized positron interacting with the electrons around a defect requires the simultaneous self-consistent calculation of the electronic structure and the positron state. This is in principle possible in the two component density functional theory. However, the approximation, in which the electronic structure without the positron influence is used and the electron-positron correlation effects are described by local enhancement factors, has turned out to be feasible in practice and also accurate enough in predicting positron annihilation characteristics. Moreover, a non-self-consistent electron structure is sufficient in many cases. This enables an efficient calculation method in which the positron wave function can be solved in three dimensions for arbitrary defect geometries. Enhancement models for simple metals, transition metals, and semiconductors are represented. Thereafter, applications to vacancies, vacancy clusters, and vacancy-impurity complexes are shown. The positron trapping by defects is mediated by the transfer of the positron binding energy to the solid in the form of electron-hole pairs and phonons. The trapping phenomenon is discussed in the case of metals and semiconductors. Semiconductors are especially challenging because the existence of the energy gap makes the low energy electron-hole excitations impossible and because the defects have different charge states effecting strongly on the trapping rate. (author)

  7. Design of a transmission electron positron microscope

    International Nuclear Information System (INIS)

    Doyama, Masao; Inoue, M.; Kogure, Y.; Hayashi, Y.; Yoshii, T.; Kurihara, T.; Tsuno, K.

    2003-01-01

    This paper reports the plans and design of positron-electron microscopes being built at KEK (High Energy Accelerator Research Organization), Tsukuba, Japan. A used electron microscope is altered. The kinetic energies of positrons produced by accelerators or by nuclear decays are not a unique value but show a spread over in a wide range. Positron beam is guided to a transmission electron microscope (JEM100SX). Positrons are moderated by a tungsten foil, are accelerated and are focused on a nickel sheet. The monochromatic focused beam is injected into an electron microscope. The focusing and aberration of positrons are the same as electrons in a magnetic system which are used in commercial electron microscopes. Imaging plates are used to record positron images for the transmission electron microscope. (author)

  8. Positron deep level transient spectroscopy — a new application of positron annihilation to semiconductor physics

    Science.gov (United States)

    Beling, C. D.; Fung, S.; Au, H. L.; Ling, C. C.; Reddy, C. V.; Deng, A. H.; Panda, B. K.

    1997-05-01

    Recent positron mobility and lifetime measurements made on ac-biased metal on semi-insulating GaAs junctions, which have identified the native EL2 defect through a determination of the characteristic ionization energy of the donor level, are reviewed. It is shown that these measurements point towards a new spectroscopy, tentatively named positron-DLTS (deep level transient spectroscopy), that is the direct complement to conventional DLTS in that it monitors transients in the electric field of the depletion region rather than the inversely related depletion width, as deep levels undergo ionization. In this new spectroscopy, which may be applied to doped material by use of a suitable positron beam, electric field transients are monitored through the Doppler shift of the annihilation radiation resulting from the drift velocity of the positron in the depletion region. Two useful extensions of the new spectroscopy beyond conventional capacitance-DLTS are suggested. The first is that in some instances information on the microstructure of the defect causing the deep level may be inferred from the sensitivity of the positron to vacancy defects of negative and neutral charge states. The second is that the positron annihilation technique is intrinsically much faster than conventional DLTS with the capability of observing transients some 10 6 times faster, thus allowing deep levels (and even shallow levels) to be investigated without problems associated with carrier freeze-out.

  9. Positron probes of the Ge(1 0 0) surface: The effects of surface reconstructions and electron-positron correlations on positron trapping and annihilation characteristics

    Energy Technology Data Exchange (ETDEWEB)

    Fazleev, N.G. [Department of Physics, University of Texas at Arlington, Box 19059, Arlington, TX 76019-0059 (United States) and Department of Physics, Kazan State University, Kazan 420008 (Russian Federation)]. E-mail: Fazleev@uta.edu; Jung, E. [Department of Physics, University of Texas at Arlington, Box 19059, Arlington, TX 76019-0059 (United States); Weiss, A.H. [Department of Physics, University of Texas at Arlington, Box 19059, Arlington, TX 76019-0059 (United States)

    2007-08-15

    Positron annihilation induced Auger electron spectroscopy (PAES) has been applied to study the Ge(1 0 0) surface. The high-resolution PAES spectrum from the Ge(1 0 0) surface displays several strong Auger peaks corresponding to M{sub 4,5}N{sub 1}N{sub 2,3}, M{sub 2,3}M{sub 4,5}M{sub 4,5}, M{sub 2,3}M{sub 4,5}V and M{sub 1}M{sub 4,5}M{sub 4,5} Auger transitions. The integrated peak intensities of Auger transitions are used to obtain experimental annihilation probabilities for the Ge 3d and 3p core level electrons. These experimental results are analyzed by performing calculations of positron surface states and annihilation characteristics of surface trapped positrons with relevant Ge core-level electrons for the non-reconstructed and reconstructed Ge(1 0 0)-p(2 x 1), Ge(1 0 0)-p(2 x 2) and Ge(1 0 0)-c(4 x 2) surfaces. It is found that the positron surface state wave function extends into the Ge lattice in the regions where atoms are displaced from their ideal terminated positions due to reconstructions. Estimates of the positron binding energy and the positron annihilation characteristics reveal their sensitivity to the specific atomic structure of the topmost layers of Ge(1 0 0). A comparison with PAES data reveals an agreement with theoretical core annihilation probabilities for the Auger transitions considered.

  10. Dynamic behavior of ion acoustic waves in electron-positron-ion magnetoplasmas with superthermal electrons and positrons

    Science.gov (United States)

    Saha, Asit; Pal, Nikhil; Chatterjee, Prasanta

    2014-10-01

    The dynamic behavior of ion acoustic waves in electron-positron-ion magnetoplasmas with superthermal electrons and positrons has been investigated in the framework of perturbed and non-perturbed Kadomtsev-Petviashili (KP) equations. Applying the reductive perturbation technique, we have derived the KP equation in electron-positron-ion magnetoplasma with kappa distributed electrons and positrons. Bifurcations of ion acoustic traveling waves of the KP equation are presented. Using the bifurcation theory of planar dynamical systems, the existence of the solitary wave solutions and the periodic traveling wave solutions has been established. Two exact solutions of these waves have been derived depending on the system parameters. Then, using the Hirota's direct method, we have obtained two-soliton and three-soliton solutions of the KP equation. The effect of the spectral index κ on propagations of the two-soliton and the three-soliton has been shown. Considering an external periodic perturbation, we have presented the quasi periodic behavior of ion acoustic waves in electron-positron-ion magnetoplasmas.

  11. Dynamic behavior of ion acoustic waves in electron-positron-ion magnetoplasmas with superthermal electrons and positrons

    Energy Technology Data Exchange (ETDEWEB)

    Saha, Asit, E-mail: asit-saha123@rediffmail.com, E-mail: prasantachatterjee1@rediffmail.com [Department of Mathematics, Sikkim Manipal Institute of Technology, Majitar, Rangpo, East-Sikkim 737136 (India); Department of Mathematics, Siksha Bhavana, Visva Bharati University, Santiniketan-731235 (India); Pal, Nikhil; Chatterjee, Prasanta, E-mail: asit-saha123@rediffmail.com, E-mail: prasantachatterjee1@rediffmail.com [Department of Mathematics, Siksha Bhavana, Visva Bharati University, Santiniketan-731235 (India)

    2014-10-15

    The dynamic behavior of ion acoustic waves in electron-positron-ion magnetoplasmas with superthermal electrons and positrons has been investigated in the framework of perturbed and non-perturbed Kadomtsev-Petviashili (KP) equations. Applying the reductive perturbation technique, we have derived the KP equation in electron-positron-ion magnetoplasma with kappa distributed electrons and positrons. Bifurcations of ion acoustic traveling waves of the KP equation are presented. Using the bifurcation theory of planar dynamical systems, the existence of the solitary wave solutions and the periodic traveling wave solutions has been established. Two exact solutions of these waves have been derived depending on the system parameters. Then, using the Hirota's direct method, we have obtained two-soliton and three-soliton solutions of the KP equation. The effect of the spectral index κ on propagations of the two-soliton and the three-soliton has been shown. Considering an external periodic perturbation, we have presented the quasi periodic behavior of ion acoustic waves in electron-positron-ion magnetoplasmas.

  12. Simulation of the annihilation emission of galactic positrons

    International Nuclear Information System (INIS)

    Gillard, W.

    2008-01-01

    Positrons annihilate in the central region of our Galaxy. This has been known since the detection of a strong emission line centered on an energy of 511 keV in the direction of the Galactic center. This gamma-ray line is emitted during the annihilation of positrons with electrons from the interstellar medium. The spectrometer SPI, onboard the INTEGRAL observatory, performed spatial and spectral analyses of the positron annihilation emission. This thesis presents a study of the Galactic positron annihilation emission based on models of the different interactions undergone by positrons in the interstellar medium. The models are relied on our present knowledge of the properties of the interstellar medium in the Galactic bulge, where most of the positrons annihilate, and of the physics of positrons (production, propagation and annihilation processes). In order to obtain constraints on the positrons sources and physical characteristics of the annihilation medium, we compared the results of the models to measurements provided by the SPI spectrometer. (author)

  13. Positron probes for mechanical fatigue detection system

    International Nuclear Information System (INIS)

    Holt, W.H.; Mock, W. Jr.

    1976-01-01

    The invention comprises positron-emitting probes for use in testing samples of metals for fatique by positron annihilation techniques comprising a substrate made from the same material as the test sample, positron-emitting material supported by one surface of the substrate, and a cover for the emitting material, the cover is sealed to the substrate and is of such thinness and density as to provide a window through which positron passage is unimpeded

  14. 4.5 Tesla magnetic field reduces range of high-energy positrons -- Potential implications for positron emission tomography

    International Nuclear Information System (INIS)

    Wirrwar, A.; Vosberg, H.; Herzog, H.; Halling, H.; Weber, S.; Mueller-Gaertner, H.W.; Forschungszentrum Juelich GmbH

    1997-01-01

    The authors have theoretically and experimentally investigated the extent to which homogeneous magnetic fields up to 7 Tesla reduce the spatial distance positrons travel before annihilation (positron range). Computer simulations of a noncoincident detector design using a Monte Carlo algorithm calculated the positron range as a function of positron energy and magnetic field strength. The simulation predicted improvements in resolution, defined as full-width at half-maximum (FWHM) of the line-spread function (LSF) for a magnetic field strength up to 7 Tesla: negligible for F-18, from 3.35 mm to 2.73 mm for Ga-68 and from 3.66 mm to 2.68 mm for Rb-82. Also a substantial noise suppression was observed, described by the full-width at tenth-maximum (FWTM) for higher positron energies. The experimental approach confirmed an improvement in resolution for Ga-68 from 3.54 mm at 0 Tesla to 2.99 mm FWHM at 4.5 Tesla and practically no improvement for F-18 (2.97 mm at 0 Tesla and 2.95 mm at 4.5 Tesla). It is concluded that the simulation model is appropriate and that a homogeneous static magnetic field of 4.5 Tesla reduces the range of high-energy positrons to an extent that may improve spatial resolution in positron emission tomography

  15. Defect characterization with positron annihilation

    International Nuclear Information System (INIS)

    Granatelli, L.; Lynn, K.G.

    1980-01-01

    Positron annihilation in metal crystals is reviewed. A brief introduction to the positron annihilation technique is presented first. Then the ability of the positron technique to perform microstructural characterization of four types of lattice defects (vacancies, voids, dislocations, grain boundaries) is discussed. It is frequently not possible to obtain samples that contain only one type of defect in nonnegligible concentrations. Such situations exist for some alloys and for fatigued metal samples. Finally, the current limitations and some future prospects of the technique are presented. 79 references, 14 figures, 1 table

  16. Fundamentals of positron emission tomography

    International Nuclear Information System (INIS)

    Ostertag, H.

    1989-01-01

    Positron emission tomography is a modern radionuclide method of measuring physiological quantities or metabolic parameters in vivo. The methods is based on: (1) Radioactive labelling with positron emitters; (2) the coincidence technique for the measurement of the annihilation radiation following positron decay; (3) analysis of the data measured using biological models. The basic aspects and problems of the method are discussed. The main fields of future research are the synthesis of new labelled compounds and the development of mathematical models of the biological processes to be investigated. (orig.) [de

  17. Atomic collisions involving pulsed positrons

    DEFF Research Database (Denmark)

    Merrison, J. P.; Bluhme, H.; Field, D.

    2000-01-01

    Conventional slow positron beams have been widely and profitably used to study atomic collisions and have been instrumental in understanding the dynamics of ionization. The next generation of positron atomic collision studies are possible with the use of charged particle traps. Not only can large...... instantaneous intensities be achieved with in-beam accumulation, but more importantly many orders of magnitude improvement in energy and spatial resolution can be achieved using positron cooling. Atomic collisions can be studied on a new energy scale with unprecedented precion and control. The use...

  18. Construction report of the PF slow-positron source. 1

    International Nuclear Information System (INIS)

    Enomoto, Atsushi; Kurihara, Toshikazu; Kobayashi, Hitoshi

    1993-12-01

    The slow positron source utilizing the electron beam of the 2.5 GeV electron beam accelerator which is the synchrotron radiation injector is being constructed. The outline of the project and the present state of construction are reported. As of November, 1993, by injecting the electron beam of about 10 W to the targets for producing positrons, the slow positrons of 4 x 10 4 e + /s has been obtained in the laboratory. Finally, with the electron beam of 30 kW, it is aimed at to obtain the slow positron beam of 2 x 10 9 e + /s. In the slow positron source, the electron beam from the 2.5 GeV linear accelerator is used as the primary beam. This beam is led to the target with electromagnets. Radiation shields were strengthened, and the electrostatic lens system was attached to efficiently extract and send out slow positrons. The conveying system for slow positrons is explained. Primary electron beam, target and moderator for producing slow positrons, the change to continuous current of pulsed slow positron beam and the heightening of luminance of slow positron beam, and the experiment on the utilization of slow positron beam, and the control system for positron conveyance path are reported. (K.I.)

  19. A study of positron irradiated porous silicon

    International Nuclear Information System (INIS)

    Huang Yuanming; Xue Qing; Zhai Baogai; Xu Aijun; Liu Shewen; Yu Weizhong

    1998-01-01

    The effect of positron irradiation on photoluminescence (PL) of porous silicon has been studied. After four hour positron irradiation, the red PL spectrum of porous silicon blue shifts into greenish spectral region, and a higher energy luminescence band is introduced into this blueshifted spectrum. The fourier transform infrared absorption experiment shows that the positron irradiation can cause further oxidization of porous silicon. A possible mechanism causing this change of PL spectra after positron irradiation is suggested

  20. Nuclear-charge and positron-energy dependence of the single-quantum annihilation of positrons

    International Nuclear Information System (INIS)

    Palathingal, J.C.; Asoka-Kumar, P.; Lynn, K.G.; Wu, X.Y.

    1995-01-01

    We report an experimental study of the single-quantum annihilation of positrons in a number of elements having atomic numbers between 49 and 90, utilizing a monoenergetic positron beam. Measurements were made of the differential cross sections for the forward direction for the K, L, and M atomic shells in targets of Th, Pb, Au, Hf, Gd, and In, having thicknesses that vary between 2.7 and 4.4 mg/cm 2 . A shielded HPGe detector of high relative photopeak efficiency was used for recording the photon spectrum. Values for the individual atomic shells were obtained in the positron kinetic-energy range 1.02--2.24 MeV. It was observed that the differential cross sections measured for the forward direction varied with energy for each major shell almost alike so that the shell ratios appeared to remain constant while the positron energy varied. The dependence of the cross section on the atomic number Z of the target element was tested for each of the major shells at various energies of measurement. It was seen that the cross sections follow a Z ν relation with ν∼5.1 as the exponent for the K shell. For the higher shells, the exponent is approximately 6.4, which is significantly larger. It was also noted that this pattern is fairly independent of the positron energy. The results on the Z dependence are seen to be clearly at variance with the most updated theoretical predictions

  1. Bulk Materials Analysis Using High-Energy Positron Beams

    International Nuclear Information System (INIS)

    Glade, S C; Asoka-Kumar, P; Nieh, T G; Sterne, P A; Wirth, B D; Dauskardt, R H; Flores, K M; Suh, D; Odette, G.R.

    2002-01-01

    This article reviews some recent materials analysis results using high-energy positron beams at Lawrence Livermore National Laboratory. We are combining positron lifetime and orbital electron momentum spectroscopic methods to provide electron number densities and electron momentum distributions around positron annihilation sites. Topics covered include: correlation of positron annihilation characteristics with structural and mechanical properties of bulk metallic glasses, compositional studies of embrittling features in nuclear reactor pressure vessel steel, pore characterization in Zeolites, and positron annihilation characteristics in alkali halides

  2. Investigation and realization of a slow-positron beam

    International Nuclear Information System (INIS)

    Ruiz, Nicolas

    2011-01-01

    This research thesis first proposes a presentation of the GBAR project (Gravitational Behaviour of Anti-hydrogen at Rest) within which this research took place, and which aims at performing the first direct test of the Weak Equivalence Principle on anti-matter by studying the free fall of anti-hydrogen atoms in the Earth gravitational field. The author presents different aspects of this project: scientific objective, experiment principle and structure, detailed structure (positron beam, positron trap, positron/positronium conversion, anti-proton beam, trapping, slowing down and neutralisation of anti-hydrogen ions). The author then reports the design of the positron beam: study of source technology, studies related to the fast positron source, design of the low positron line (approach, functions, simulations, technology). The two last chapters report the construction and the characterization of the slow-positron line [fr

  3. Ultrarelativistic electron and positron radiation in planar channeling

    International Nuclear Information System (INIS)

    Kalashnikov, N.P.; Olchack, A.S.

    1980-01-01

    The coherent electromagnetic radiation from channeling electrons and positrons is given by similar expression. However for the channeling positrons the close collisions are suppressed due to the fact that the positron wave function is exponentially small near the atoms of the crystal lattice. It follows that the coherent bremsstrahlung decreases for the channeling positrons. We have investigated the ultrarelativistic channeling electron and positron radiations, connected with the electromagnetic transitions from the continuum spectrum states to the quasi-bound spectrum states and between the different quasi-bound spectrum states. The radiation probabilities are calculated by using the model continuum planar potential. It is shown that the radiation from the channeling electrons is several orders of magnitude larger than the positron radiation, while the electron and positron radiation have similar characteristics such as frequency limitation and angular distribution of the radiation. (orig.)

  4. Evaluation of scintillators and semiconductor detectors to image three-photon positron annihilation for positron emission tomography

    International Nuclear Information System (INIS)

    Abuelhia, E.; Spyrou, N.M.; Kacperski, K.; College University, Middlesex Hospital, London

    2008-01-01

    Positron emission tomography (PET) is rapidly becoming the main nuclear imaging modality of the present century. The future of PET instrumentation relies on semiconductor detectors because of their excellent characteristics. Three-photon positron annihilation has been recently investigated as a novel imaging modality, which demands the crucial high energy resolution of semiconductor detector. In this work the evaluation of the NaI(Tl) scintillator and HPGe and CdZTe semiconductor detectors, to construct a simple three-photon positron annihilation scanner has been explored. The effect of detector and scanner size on spatial resolution (FWHM) is discussed. The characteristics: energy resolution versus count rate and point-spread function of the three-photon positron annihilation image profile from triple coincidence measurements were investigated. (author)

  5. Positron age-momentum correlation in metal oxide powders as catalytic materials

    International Nuclear Information System (INIS)

    Kishimoto, Y.; Ito, K.; Tanigawa, S.; Tsuda, N.

    1982-01-01

    Annihilation characteristics of positrons in fine particles of various types of metal oxides (MgO, SiO 2 , #betta#-Al 2 O 3 , TiO 2 , ZnO and NiO) were studied by the two parameter correlation measurements between the positron age and the momentum of annihilating pairs. It was found that the momentum dependence of lifetime can be classified into three types, that is, the bell shape tau-E relation (Type I : #betta#-Al 2 O 3 ), the W-like one (Type II : ZnO, NiO, MgO and TiO 2 ) and the M-like one (Type III : SiO 2 ). This variation may be due to the difference in the formation and reaction of positroniums at the surface of fine particles of different oxides reflecting the nature of acid points or basic points in catalytic reactions. Particularly, the frequent occurrence of the conversion process of ortho-Ps was observed. (Auth.)

  6. The rise in the positron fraction. Distance limits on positron point sources from cosmic ray arrival directions and diffuse gamma-rays

    Energy Technology Data Exchange (ETDEWEB)

    Gebauer, Iris; Bentele, Rosemarie [Karlsruhe Institute of Technology, Karlsruhe (Germany)

    2016-07-01

    The rise in the positron fraction as observed by AMS and previously by PAMELA, cannot be explained by the standard paradigm of cosmic ray transport in which positrons are produced by cosmic-ray-gas interactions in the interstellar medium. Possible explanations are pulsars, which produce energetic electron-positron pairs in their rotating magnetic fields, or the annihilation of dark matter. Here we assume that these positrons originate from a single close-by point source, producing equal amounts of electrons and positrons. The propagation and energy losses of these electrons and positrons are calculated numerically using the DRAGON code, the source properties are optimized to best describe the AMS data. Using the FERMI-LAT limits on a possible dipole anisotropy in electron and positron arrival directions, we put a limit on the minimum distance of such a point source. The energy losses that these energetic electrons and positrons suffer on their way through the galaxy create gamma ray photons through bremsstrahlung and Inverse Compton scattering. Using the measurement of diffuse gamma rays from Fermi-LAT we put a limit on the maximum distance of such a point source. We find that a single electron positron point source powerful enough to explain the locally observed positron fraction must reside between 225 pc and 3.7 kpc distance from the sun and compare to known pulsars.

  7. Studies of positron induced luminescence from polymers

    International Nuclear Information System (INIS)

    Xu, J.; Hulett, L.D. Jr.; Lewis, T.A.; Tolk, N.H.

    1994-01-01

    Light emission from polymers (anthracene dissolved in polystryrene) induced by low-energy positrons and electrons has been studied. Results indicate a clear difference between optical emissions under positron and electron bombardment. The positron-induced luminescence spectrum is believed to be generated by both collisional and annihilation processes

  8. Cardiac positron tomography

    International Nuclear Information System (INIS)

    Geltmann, E.M.; Roberts, R.; Sobel, B.E.

    1980-01-01

    Positron emission tomography (PET) performed after the administration of the positron-emitting radionuclides carbon-11 ( 11 C), nitrogen-13 ( 13 N), oxygen-15 ( 15 O) and fluorine-18 ( 18 F) has permitted the improved noninvasive assessment of the regional myocardial metabolism of normal physiologic substrates and intermediates and their cogeners. In experimental animals, the rate of oxidation of 11 C-palmitate correlates closely with other indexes of oxygen consumption, and the extraction of 11 C-palmitate (like that of 18 F-fatty acids and 18 F-fluoredoxyglucose) ist markedly diminished in regions of myocardial ischemia. In both experimental animals and in patients, myocardial infarct site and size, determined by positron emission tomography after the intravenous injection of 11 C-palmitate, correlate closely with the electrocardiographic infarct locus and enzymatically estimated infarct size as well as with the location and extent of regional left ventricular wall motion abnormalities. PET offers promise for assessment of flow as well despite the complexities involved. PET with 13 NH 3 appears to provide one useful qualitative index, although this tracer ist actively metabolized. Because of the quantitative capabilities of positron emission tomography and the rapid progress which is being made in the development of fast scan, multi-slice, and gated instrumentation, this technique is likely to facilitate improved understanding and characterization of regional myocardial metabolism and blood flow in man under physiological and pathophysiological conditions. (orig.) [de

  9. Positron lifetime experiments in indium selenide

    International Nuclear Information System (INIS)

    Cruz, R.M. de la; Pareja, R.

    1988-01-01

    Positron lifetime experiments have been performed on as-grown samples which had been isochronally annealed up to 820 K and plastically deformed and these experiments yield a constant lifetime of 282 ± 2 ps which is attributed to bulk positron states in InSe. Electron-irradiated samples exhibit a two-component spectrum, revealing the presence of positron traps which anneal out at about 330 K. The nature of the native shallow donors in InSe is discussed in the light of the results, which support the idea that native donor centres are probably interstitial In atoms rather than Se vacancies. Positron trapping observed in the electron-irradiated samples is attributed to defects related to In vacancies. (author)

  10. Cosmic Ray Positrons from Pulsars

    Science.gov (United States)

    Harding, Alice K.

    2010-01-01

    Pulsars are potential Galactic sources of positrons through pair cascades in their magnetospheres. There are, however, many uncertainties in establishing their contribution to the local primary positron flux. Among these are the local density of pulsars, the cascade pair multiplicities that determine the injection rate of positrons from the pulsar, the acceleration of the injected particles by the pulsar wind termination shock, their rate of escape from the pulsar wind nebula, and their propagation through the interstellar medium. I will discuss these issues in the context of what we are learning from the new Fermi pulsar detections and discoveries.

  11. Undulator-based production of polarized positrons

    Energy Technology Data Exchange (ETDEWEB)

    Alexander, G. [Tel-Aviv Univ. (Israel); Barley, J. [Cornell Univ., Ithaca, NY (United States); Batygin, Y. [SLAC, Menlo Park, CA (US)] (and others)

    2009-05-15

    Full exploitation of the physics potential of a future International Linear Collider will require the use of polarized electron and positron beams. Experiment E166 at the Stanford Linear Accelerator Center (SLAC) has demonstrated a scheme in which an electron beam passes through a helical undulator to generate photons (whose first-harmonic spectrum extended to 7.9 MeV) with circular polarization, which are then converted in a thin target to generate longitudinally polarized positrons and electrons. The experiment was carried out with a one-meter-long, 400-period, pulsed helical undulator in the Final Focus Test Beam (FFTB) operated at 46.6 GeV. Measurements of the positron polarization have been performed at five positron energies from 4.5 to 7.5 MeV. In addition, the electron polarization has been determined at 6.7MeV, and the effect of operating the undulator with a ferrofluid was also investigated. To compare the measurements with expectations, detailed simulations were made with an upgraded version of GEANT4 that includes the dominant polarization-dependent interactions of electrons, positrons, and photons with matter. The measurements agree with calculations, corresponding to 80% polarization for positrons near 6 MeV and 90% for electrons near 7 MeV. (orig.)

  12. Positron lifetime study of neutron-irradiated molybdenum

    International Nuclear Information System (INIS)

    Hinode, Kenji; Tanigawa, Shoichiro; Kumakura, Hiroaki; Doyama, Masao; Shiraishi, Kensuke.

    1978-01-01

    Annealing behavior of fast-neutron-irradiated molybdenum was studied by means of positron lifetime technique. It was found that Stage III annealing can be mainly identified as the vacancy migration process from the detailed analyses of data. The void growth after successive high temperature annealings was clearly detected through the changes of positron lifetime parameters. An attempt to analyse the size distribution of voids from positron lifetime spectra was presented, and discussions on the evaluation of void concentration from positron data are also given. (author)

  13. Positron annihilation spectroscopy in materials structure studies

    International Nuclear Information System (INIS)

    Grafutin, Viktor I; Prokop'ev, Evgenii P

    2002-01-01

    A relatively new method of materials structure analysis - positron annihilation spectroscopy (PAS) - is reviewed. Measurements of positron lifetimes, the determination of positron 3γ- and 2γ-annihilation probabilities, and an investigation of the effects of different external factors on the fundamental characteristics of annihilation constitute the basis for this promising method. The ways in which the positron annihilation process operates in ionic crystals, semiconductors, metals and some condensed matter systems are analyzed. The scope of PAS is described and its prospects for the study of the electronic and defect structures are discussed. The applications of positron annihilation spectroscopy in radiation physics and chemistry of various substances as well as in physics and chemistry of solutions are exemplified. (instruments and methods of investigation)

  14. Examination of the e{sup +} and e{sup +}e{sup -} pair emission from heavy ion collisions at the EPoS II spectrometer; Untersuchung der e{sup +}- und e{sup +}e{sup -}-Paaremission aus Schwerionenkollisionen mit dem EPoS II Spektrometer

    Energy Technology Data Exchange (ETDEWEB)

    Baumann, J.

    1996-12-01

    In the course of examination of the positron and positron-electron pair emission from heavy ion collisions at the Coulomb barrier, the research groups EPOS I and ORANGE have found a number of line structures in the measured positron energy and cumulative pair energy spectra which up to present could not be fully explained, as theoretical interpretations so far remain inconsistent in some respects. For clarification, further measurements have been made at the completely new designed EPoS II spectrometer. Reproducibility of the lines is possible at a high level of statistical significance. (orig./CB) [Deutsch] Bei Untersuchungen der Positron- und Positron- Elektron- Paaremissionaus Schwerionenkollisionen an der Coulombbarriere wurde von den Gruppen EPOS I und ORANGE eine Reihe von Linienstrukturen in den gemessenen Positronenenergie- und Paarsummenenergiespektren beobachtet, fuer die bislang keine in allen Punkten konsistente, theoretische Erklaerunggefunden werden konnte. Um ihre Ursachen zu klaeren, wurden mit dem voellig neu aufgebauten EPoS II Spektrometer weitere Messreihen durgefuehrt. Die Reproduzierbarkeit der Linien ist auf einem hohen statistischen Signifikanzniveau moeglich.

  15. Digital positron annihilation spectrometer

    International Nuclear Information System (INIS)

    Cheng Bin; Weng Huimin; Han Rongdian; Ye Bangjiao

    2010-01-01

    With the high speed development of digital signal process, the technique of the digitization and processing of signals was applied in the domain of a broad class of nuclear technique. The development of digital positron lifetime spectrometer (DPLS) is more promising than the conventional positron lifetime spectrometer equipped with nuclear instrument modules. And digital lifetime spectrometer has many advantages, such as low noise, long term stability, flexible online or offline digital processing, simple setup, low expense, easy to setting, and more physical information. Digital constant fraction discrimination is for timing. And a new method of optimizing energy windows setting for digital positron lifetime spectrometer is also developed employing the simulated annealing for the convenient use. The time resolution is 220ps and the count rate is 200cps. (authors)

  16. Positron emission tomography imaging--technical considerations

    International Nuclear Information System (INIS)

    Muehllehner, G.; Karp, J.S.

    1986-01-01

    Positron imaging instrumentation has improved rapidly in the last few years. Scanners currently under development are beginning to approach fundamental limits set by positron range and noncolinearity effects. This report reviews the latest developments in positron emission tomography (PET) instrumentation, emphasizing the development of coding schemes that reduce the complexity and cost of high-resolution scanners. The relative benefits of using time-of-flight (TOF) information is discussed as well. 68 references

  17. Generation and application of slow positrons based on a electron LINAC

    International Nuclear Information System (INIS)

    Kurihara, Toshikazu

    2002-01-01

    History of slow positron in Institute of Materials Structure Science High Energy Accelerator Research Organization is explained. The principle of generation and application of intense positron beam is mentioned. Two sources of intense positron are radioactive decay of radioactive isotopes emitting positron and electron-positron pair creation. The radioactive decay method uses 58 Co, 64 Cu, 11 C, 13 N, 15 O and 18 F. The electron-positron pair creation method uses nuclear reactor or electron linear accelerator (LINAC). The positron experimental facility in this organization consists of electron LINAC, slow positron beam source, positron transport and experimental station. The outline of this facility is started. The intense slow positron beam is applied to research positronium work function, electron structure of surface. New method such as combination of positron lifetime measurement and slow positron beam or Auger electron spectroscopy by positron annihilation excitation and positron reemission microscope are developed. (S.Y.)

  18. Experimental Study of a Positron\\\\ Source Using Channeling

    CERN Multimedia

    Gavrykov, V; Kulibaba, V; Baier, V; Beloborodov, K; Bojenok, A; Bukin, A; Burdin, S; Dimova, T; Druzhinin, V; Dubrovin, M; Seredniakov, S; Shary, V; Strakhovenko, V; Keppler, P; Major, J; Bogdanov, A V; Potylitsin, A; Vnoukov, I; Artru, X; Lautesse, P; Poizat, J-C; Remillieux, J

    2002-01-01

    Many simulations have predicted that the yield of positrons, resulting from the interaction of fast electrons in a solid target, increases if the target is a crystal oriented with a major axis parallel to the electron beam. Tests made at Orsay and Tokyo confirmed these expectations. The experiment WA 103 concerns the determination of the main characteristics (emittance, energy spread) of a crystal positron source which could replace advantageously the conventional positron converters foreseen in some linear collider projects. The main element of the set-up is a magnetic spectrometer, using a drift chamber, where the positron trajectories are reconstructed (see Figure 1) A first run has been operated in july 2000 and the first results showed, as expected, a significant enhancement in photon and positron generation along the $$ axis of the tungsten crystal. Indications about a significant increase in the number of soft photons and positrons were also gathered : this point is of importance for the positron colle...

  19. Toward a European Network of Positron Laboratories

    Directory of Open Access Journals (Sweden)

    Karwasz Grzegorz P.

    2015-12-01

    Full Text Available Some applications of controlled-energy positron beams in material studies are discussed. In porous organic polysilicates, measurements of 3γ annihilation by Doppler broadening (DB method at the Trento University allowed to trace pore closing and filling by water vapor. In silicon coimplanted by He+ and H+, DB data combined with positron lifetime measurements at the München pulsed positron beam allowed to explain Si blistering. Presently measured samples of W for applications in thermonuclear reactors, irradiated by W+ and electrons, show vast changes of positron lifetimes, indicating complex dynamics of defects.

  20. Recent developments in the theory of positrons at surfaces

    International Nuclear Information System (INIS)

    Walker, A.B.

    1989-01-01

    Positron beams of ever brighter intensity are now establishing themselves as a novel surface probe enabling a wide variety of spectroscopies. The production of high positron intensities and exploitation of the beams depends critically on our understanding of the complex behaviour of positrons at and near surfaces. I will review progress on the theory of positron-surface interactions and of the implantation and diffusion of low energy positrons. Applications of this theory to a variety of experimental techniques such as ACAR (Angular Correlation by Annihilation Radiation) spectra, angle resolved positronium (Ps) spectroscopy, REPELS (Reemitted Positron Energy Loss Spectroscopy), LEPD (Low Energy Positron Diffraction) and measurements of defect profiles will be discussed. 24 refs. (author)

  1. Simulation of the longitudinal instabilities of the asymmetric bunches

    International Nuclear Information System (INIS)

    Dai Jianping; Zhao Zhentang

    2002-01-01

    The computational model of the code used to simulate the longitudinal instabilities of the asymmetric bunches was introduced. The growth rates of the longitudinal instabilities of the symmetric bunches got by this code were compared with those got by the code ZAP, and they were almost the same. As an example, the simulation results of the BEPC-II were presented

  2. Design and Characterization of a Three-Dimensional Positron Annihilation Spectroscopy System Using a Low-Energy Positron Beam

    Science.gov (United States)

    2012-03-22

    Technique Applied to Measure Oxygen -Atom Defects in 6H Silicon Carbide”. 2010. [31] Y. C. Jean , P. E. Mallon and D. M. Schrader. Principles and Applications...that result in β+ emission, by photon interactions with nuclei and subsequent pair production, or by β+ decays from radioactive isotopes made by...reactions for creating positrons [7], some of which are used to to create radioactive isotopes that β+ decay. Regardless of the positron source, positrons

  3. Cyclotrons and positron emitting radiopharmaceuticals

    International Nuclear Information System (INIS)

    Wolf, A.P.; Fowler, J.S.

    1984-01-01

    The state of the art of Positron Emission Tomography (PET) technology as related to cyclotron use and radiopharmaceutical production is reviewed. The paper discusses available small cyclotrons, the positron emitters which can be produced and the yields possible, target design, and radiopharmaceutical development and application. 97 refs., 12 tabs

  4. Positron emission tomography now and in the future

    International Nuclear Information System (INIS)

    Vaalburg, W.

    1987-01-01

    A survey is given of positron emission tomography used in nuclear medicine. The production of positron emitting radionuclides is discussed. The development of positron detectors is described. The application of positron emission tomography in cardiology, oncology and neurology is treated. The authors conclude that PET is a unique method to examine metabolic processes, although the method is still in its infancy. 7 refs.; 1 table

  5. Positron creation in superheavy quasi-molecules

    International Nuclear Information System (INIS)

    Mueller, B.

    1976-01-01

    The review of positron creation in superheavy quasi-molecules includes spontaneous positron emission from superheavy atoms, supercritical quasi-molecules, background effects, and some implications of the new ground state. 66 references

  6. Progress toward magnetic confinement of a positron-electron plasma: nearly 100% positron injection efficiency into a dipole trap

    Science.gov (United States)

    Stoneking, Matthew

    2017-10-01

    The hydrogen atom provides the simplest system and in some cases the most precise one for comparing theory and experiment in atomics physics. The field of plasma physics lacks an experimental counterpart, but there are efforts underway to produce a magnetically confined positron-electron plasma that promises to represent the simplest plasma system. The mass symmetry of positron-electron plasma makes it particularly tractable from a theoretical standpoint and many theory papers have been published predicting modified wave and stability properties in these systems. Our approach is to utilize techniques from the non-neutral plasma community to trap and accumulate electrons and positrons prior to mixing in a magnetic trap with good confinement properties. Ultimately we aim to use a levitated superconducting dipole configuration fueled by positrons from a reactor-based positron source and buffer-gas trap. To date we have conducted experiments to characterize and optimize the positron beam and test strategies for injecting positrons into the field of a supported permanent magnet by use of ExB drifts and tailored static and dynamic potentials applied to boundary electrodes and to the magnet itself. Nearly 100% injection efficiency has been achieved under certain conditions and some fraction of the injected positrons are confined for as long as 400 ms. These results are promising for the next step in the project which is to use an inductively energized high Tc superconducting coil to produce the dipole field, initially in a supported configuration, but ultimately levitated using feedback stabilization. Work performed with the support of the German Research Foundation (DFG), JSPS KAKENHI, NIFS Collaboration Research Program, and the UCSD Foundation.

  7. Positron studies of metal-oxide-semiconductor structures

    Science.gov (United States)

    Au, H. L.; Asoka-Kumar, P.; Nielsen, B.; Lynn, K. G.

    1993-03-01

    Positron annihilation spectroscopy provides a new probe to study the properties of interface traps in metal-oxide semiconductors (MOS). Using positrons, we have examined the behavior of the interface traps as a function of gate bias. We propose a simple model to explain the positron annihilation spectra from the interface region of a MOS capacitor.

  8. In-situ positron emission of CO oxidation

    NARCIS (Netherlands)

    Vonkeman, K.A.; Jonkers, G.; Wal, van der S.W.A.; Santen, van R.A.

    1993-01-01

    Using a Neuro ECAT positron tomog., the Positron Emission computed Tomog. (PET) was utilized to image the catalytic oxidn. of CO by using CO and CO2, labeled with short lived positron emitting nuclides. Studies were performed over highly dispersed CeO2/g-Al2O3 supported Pt and Rh catalysts. With a

  9. Low-energy positron and electron diffraction and positron-stimulated secondary electron emission from Cu(100)

    International Nuclear Information System (INIS)

    Weiss, A.H.

    1983-01-01

    The results of two series of experiments are reported. In the first, an electrostatically guided beam of low-energy (40-400 eV) positrons, delta/sub p/ was used to study low-energy positron diffraction (LEPD) from a Cu(100) surface under ultrahigh-vacuum conditions. Low-energy electron diffraction (LEED) data were obtained from the same sample in the same apparatus. Comparison of LEPD and LEED intensity versus energy data with model calculations made using computer programs developed by C.B. Duke and collaborators indicated that: LEPD data is adequately modeled using potentials with no exchange-correlation term. The inelastic mean free path, lambda/sub ee/, is shorter for positrons than for electrons at low (< approx.80 eV). LEED is better than LEPD at making a determination of the first-layer spacing of Cu(100) for the particular data set reported. In the second set of experiments, the same apparatus and sample were used to compare positron- and electron-stimulated secondary-electron emission (PSSEE and ESSEE). The results were found to be consistent with existing models of secondary-electron production for metals. The energy distributions of secondary-electrons had broad low-energy (<10 eV) peaks for both positron and electron stimulation. But the PSEE distribution showed no elastic peak. Measurements of secondary-electron angular distributions, found to be cosine-like in both the PSSEE and ESSEE case, were used to obtain total secondary yield ratios, delta, at four beam energies ranging from 40-400 eV. The secondary yield ratio for primary positrons and the yield for primary electrons, delta/sub e/, were similar at these energies. For 400-eV primary particles the secondary yields were found to be delta/sub p/ = 0.94 +/- 0.12 and delta/sub e/ = 0.94 +/- 0./12, giving a ratio of unity for positron-stimulated secondary yield to electron-stimulated secondary yield

  10. Positron emission tomography

    International Nuclear Information System (INIS)

    Bolwig, T.G.; Haunsoe, S.; Dahlgaard Hove, J.; Hesse, B.; Hoejgard, L.; Jensen, M.; Paulson, O.B.; Hastrup Svendsen, J.; Soelvsten Soerensen, S.

    1994-01-01

    Positron emission tomography (PET) is a method for quantitative imaging of regional physiological and biochemical parameters. Positron emitting radioactive isotopes can be produced by a cyclotron, eg. the biologically important carbon ( 11 C), oxygen ( 15 O), and nitrogen ( 13 N) elements. With the tomographic principles of the PET scanner the quantitative distribution of the administered isotopes can be determined and images can be provided as well as dynamic information on blood flow, metabolism and receptor function. In neurology PET has been used for investigations on numerous physiological processes in the brain: circulation, metabolism and receptor studies. In Parkinson's disease PET studies have been able to localize the pathology specifically, and in early stroke PET technique can outline focal areas with living but non-functioning cells, and this could make it possible to intervene in this early state. With positron emission tomography a quantitative evaluation of myocardial blood flow, glucose and fatty acid metabolism can be made as well as combined assessments of blood flow and metabolism. Combined studies of blood flow and metabolism can determine whether myocardial segments with abnormal motility consist of necrotic or viable tissue, thereby delineating effects of revascularisation. In the future it will probably be possible to characterize the myocardial receptor status in different cardiac diseases. The PET technique is used in oncology for clinical as well as more basic research on tumor perfusion and metabolism. Further, tumor uptake of positron labelled cytotoxic drugs might predict the clinical benefit of treatment. (au) (19 refs.)

  11. Positron-attachment to small molecules: Vibrational enhancement of positron affinities with configuration interaction level of multi-component molecular orbital approach

    Energy Technology Data Exchange (ETDEWEB)

    Tachikawa, Masanori [Quantum Chemistry Division, Graduate School of NanoBioScience, Yokohama City University, 22-2 Seto, Kanazawa, Yokohama 236-0027 (Japan)

    2015-12-31

    To theoretically demonstrate the binding of a positron to small polarized molecules, we have calculated the vibrational averaged positron affinity (PA) values along the local vibrational contribution with the configuration interaction level of multi-component molecular orbital method. This method can take the electron-positron correlation contribution into account through single electronic - single positronic excitation configurations. The PA values are enhanced by including the local vibrational contribution from vertical PA values due to the anharmonicity of the potential.

  12. Cyclotrons and positron emitting radiopharmaceuticals

    Energy Technology Data Exchange (ETDEWEB)

    Wolf, A.P.; Fowler, J.S.

    1984-01-01

    The state of the art of Positron Emission Tomography (PET) technology as related to cyclotron use and radiopharmaceutical production is reviewed. The paper discusses available small cyclotrons, the positron emitters which can be produced and the yields possible, target design, and radiopharmaceutical development and application. 97 refs., 12 tabs. (ACR)

  13. Automatic sup sup 1 sup sup 8 F positron source supply system for a monoenergetic positron beam

    CERN Document Server

    Saito, F; Itoh, Y; Goto, A; Fujiwara, I; Kurihara, T; Iwata, R; Nagashima, Y; Hyodo, T

    2000-01-01

    A system which supplies an intense sup sup 1 sup sup 8 F (half life 110 min) positron source produced by an AVF cyclotron through sup sup 1 sup sup 8 O(p,n) sup sup 1 sup sup 8 F reaction has been constructed. Produced sup sup 1 sup sup 8 F is transferred to a low background experiment hall through a capillary. It is electro-deposited on a graphite rod and used for a source of a slow positron beam. In the meantime the next batch of target sup sup 1 sup sup 8 O water is loaded and proton irradiation proceeds. This system makes it possible to perform continuous positron beam experiments using the 18 F positron source.

  14. Generation and application of slow positrons based on a electron LINAC

    CERN Document Server

    Kurihara, T

    2002-01-01

    History of slow positron in Institute of Materials Structure Science High Energy Accelerator Research Organization is explained. The principle of generation and application of intense positron beam is mentioned. Two sources of intense positron are radioactive decay of radioactive isotopes emitting positron and electron-positron pair creation. The radioactive decay method uses sup 5 sup 8 Co, sup 6 sup 4 Cu, sup 1 sup 1 C, sup 1 sup 3 N, sup 1 sup 5 O and sup 1 sup 8 F. The electron-positron pair creation method uses nuclear reactor or electron linear accelerator (LINAC). The positron experimental facility in this organization consists of electron LINAC, slow positron beam source, positron transport and experimental station. The outline of this facility is started. The intense slow positron beam is applied to research positronium work function, electron structure of surface. New method such as combination of positron lifetime measurement and slow positron beam or Auger electron spectroscopy by positron annihil...

  15. Simulation of a Positron Source for CEBAF

    International Nuclear Information System (INIS)

    S. Golge; A. Freyberger; C. Hyde-Wright

    2007-01-01

    A positron source for the 6 GeV (or the proposed 12 GeV upgrade) recirculating linacs at Jefferson Lab is presented. The proposed 100nA CW positron source has several unique characteristics; high incident beam power (100kW), 10 MeV incident electron beam energy, CW incident beam and CW production. Positron production with 10 MeV electrons has several advantages; the energy is below neutron threshold so the production target will not become activated during use and the absolute energy spread is bounded by the low incident energy. These advantages are offset by the large angular distribution of the outgoing positrons. Results of simulations of the positron production, capture, acceleration and injection into the recirculating linac are presented. Energy flow and thermal management of the production target present a challenge and are included in the simulations

  16. Development of slow positron beam lines and applications

    Science.gov (United States)

    Mondal, Nagendra Nath

    2018-05-01

    A positron is an antiparticle of an electron that can be formed in diverse methods: natural or artificial β-decay process, fission and fusion reactions, and a pair production of electron-positron occurred in the reactor and the high energy accelerator centers. Usually a long-lifetime radio isotope is customized for the construction of a slow positron beam lines in many laboratories. The typical intensity of this beam depends upon the strength of the positron source, moderator efficiency, and guiding, pulsing, focusing and detecting systems. This article will review a few positron beam lines and their potential applications in research, especially in the Positronium Bose-Einstein Condensation.

  17. Intense positron beam and its application to surface science

    International Nuclear Information System (INIS)

    Ito, Y.; Hirose, M.; Kanazawa, I.; Sueoka, O.; Takamura, S.; Okada, S.

    1992-01-01

    Intense pulsed slow positron beam has been produced using the 100 MeV electron LINAC of JAERI · Tokai. In order to use the beam for surface studies such as positron diffraction and positron microscopy, it was transferred from the solenoid magnetic field to field free region and then was brightness-enhanced. The beam size was reduced from 10 mmφ (in the magnetic field) to 0.5 mmφ after two stages of re-moderation. Using the intense brightness-enhanced positron beam we have observed for the first time RHEPD (Reflection High-Energy Positron Diffraction) patterns. A design of re-emission positron microscopy is also described. (author)

  18. Study of a positron generation

    International Nuclear Information System (INIS)

    Nakahara, Kazuo; Enomoto, A.; Ikeda, M.; Ohsawa, S.; Kamitani, T.; Hosoyama, K.; Takei, H.; Emoto, T.; Tani, S.

    1998-03-01

    In the Power Reactor and Nuclear Fuel Development Corporation (PNC), the following are examined as part of an application technology using a high power electron linac: monochromatic gamma ray sources, free electron lasers, and intense positron sources. This report presents the study of an intense positron source, which has been developed jointly by High Energy Accelerator Research Organization (KEK) and PNC. In this report, we describe following items for an adaptive estimate of a superconducting magnet in order to efficiently converge a positron beam. (1) The cryostat which included the superconducting magnet is manufactured. (2) An excitement test of the superconducting magnet is carried out with a magnetic substance such as the electromagnet yoke. (author)

  19. The influence of positron trapping at vacancies on a pattern of the Fermi surface of #betta#-brass studied by positron annihilation

    International Nuclear Information System (INIS)

    Rozenfeld, B.; Chabik, S.; Pajak, J.

    1982-01-01

    Angular correlations of positron annihilation quanta (ACPAQ) have been measured for differently oriented monocrystalline samples of the ordered #betta#-brass under conditions permitting the neglecting of the trapping of positrons at vacancies as well as in the case when almost all the positrons annihilate being trapped at vacancies. It has been shown that trapping of positrons at vacancies can make the observation of the directional anisotropy in electron momentum distribution impossible. (Auth.)

  20. Positron beam studies of transients in semiconductors

    International Nuclear Information System (INIS)

    Beling, C.D.; Ling, C.C.; Cheung, C.K.; Naik, P.S.; Zhang, J.D.; Fung, S.

    2006-01-01

    Vacancy-sensing positron deep level transient spectroscopy (PDLTS) is a positron beam-based technique that seeks to provide information on the electronic ionization levels of vacancy defects probed by the positron through the monitoring of thermal transients. The experimental discoveries leading to the concept of vacancy-sensing PDLTS are first reviewed. The major problem associated with this technique is discussed, namely the strong electric fields establish in the near surface region of the sample during the thermal transient which tend to sweep positrons into the contact with negligible defect trapping. New simulations are presented which suggest that under certain conditions a sufficient fraction of positrons may be trapped into ionizing defects rendering PDLTS technique workable. Some suggestions are made for techniques that might avoid the problematic electric field problem, such as optical-PDLTS where deep levels are populated using light and the use of high forward bias currents for trap filling

  1. Positron lifetime measurements on electron irradiated amorphous alloys

    International Nuclear Information System (INIS)

    Moser, P.; Hautojaervi, P.; Chamberod, A.; Yli-Kauppila, J.; Van Zurk, R.

    1981-08-01

    Great advance in understanding the nature of point defects in crystalline metals has been achieved by employing positron annihilation technique. Positrons detect vacancy-type defects and the lifetime value of trapped positrons gives information on the size of submicroscopic vacancy aglomerates and microvoids. In this paper it is shown that low-temperature electron irradiations can result in a considerable increase in the positron lifetimes in various amorphous alloys because of the formation of vacancy-like defects which, in addition of the pre-existing holes, are able to trap positrons. Studied amorphous alloys were Fe 80 B 20 , Pd 80 Si 20 , Cu 50 Ti 50 , and Fe 40 Ni 40 P 14 B 6 . Electron irradiations were performed with 3 MeV electrons at 20 K to doses around 10 19 e - /cm 2 . After annealing positron lifetime spectra were measured at 77 K

  2. Polarized positron sources for the future linear colliders

    International Nuclear Information System (INIS)

    Chaikovska, I.

    2012-01-01

    This thesis introduces the polarized positron source as one of the key element of the future Linear Collider (LC). In this context, the different schemes of the polarized positron source are described highlighting the main issues in this technology. In particular, the main focus is on the Compton based positron source adopted by the CLIC as a preferred option for the future positron source upgrade. In this case, the circularly polarized high energy gamma rays resulting from Compton scattering are directed to a production target where an electromagnetic cascade gives rise to the production of positrons by e + -e - pair conversion. To increase the efficiency of the gamma ray production stage, a multiple collision point line integrated in energy recovery linac is proposed. The simulations of the positron production, capture and primary acceleration allow to estimate the positron production efficiency and provide a simple parametrization of the Compton based polarized positron source in the view of the future LC requirements. The storage ring based Compton source option, so-called Compton ring, is also described. The main constraint of this scheme is given by the beam dynamics resulting in the large energy spread and increased bunch length affecting the gamma ray production rate. An original theoretical contribution is shown to calculate the energy spread induced by Compton scattering. Moreover, an experiment to test the gamma ray production by Compton scattering using a state-of-art laser system developed at LAL has been conducted in the framework of the 'Mighty Laser' project at the ATF, KEK. The experimental layout as well as the main results obtained are discussed in details. The studies carried out in this thesis show that the polarized positron source based on Compton scattering is a promising candidate for the future LC polarized positron source. (author)

  3. Theory of the temperature dependence of positron bulk lifetimes-implications for vacancy formation enthalpy measurements via positron experiments

    International Nuclear Information System (INIS)

    Tam, S.W.; Sinha, S.K.; Siegel, R.W.

    1977-02-01

    Temperature dependent effects, which may have a bearing on determinations of vacancy formation enthalpies in metals by positron annihilation, have been observed in certain metals. These effects have been observed to occur both at temperatures below those at which positron annihilation is most sensitive to equilibrium vacancies and at temperatures well within the vacancy-sensitive region. The effect of thermal lattice displacements on positron lifetimes in metals was investigated to help understand these phenomena

  4. New Possibilities of Positron-Emission Tomography

    Science.gov (United States)

    Volobuev, A. N.

    2018-01-01

    The reasons for the emergence of the angular distribution of photons generated as a result of annihilation of an electron and a positron in a positron-emission tomograph are investigated. It is shown that the angular distribution of the radiation intensity (i.e., the probability of photon emission at different angles) is a consequence of the Doppler effect in the center-of-mass reference system of the electron and the positron. In the reference frame attached to the electron, the angular distribution of the number of emitted photons does not exists but is replaced by the Doppler shift of the frequency of photons. The results obtained in this study make it possible to extend the potentialities of the positron-emission tomograph in the diagnostics of diseases and to obtain additional mechanical characteristics of human tissues, such as density and viscosity.

  5. Observation of magnetic resonances in electron clouds in a positron storage ring

    International Nuclear Information System (INIS)

    Pivi, M.T.F.; Ng, J.S.T.; Cooper, F.; Kharakh, D.; King, F.; Kirby, R.E.; Kuekan, B.; Spencer, C.M.; Raubenheimer, T.O.; Wang, L.F.

    2010-01-01

    The first experimental observation of magnetic resonances in electron clouds is reported. The resonance was observed as a modulation in cloud intensity for uncoated as well as TiN-coated aluminum surfaces in the positron storage ring of the PEP-II collider at SLAC. Electron clouds frequently arise in accelerators of positively charged particles, and severely impact the machines' performance. The TiN coating was found to be an effective remedy, reducing the cloud intensity by three orders of magnitude.

  6. Porous silicon investigated by positron annihilation

    International Nuclear Information System (INIS)

    Cruz, R.M. de la; Pareja, R.

    1989-01-01

    The effect of the anodic conversion in silicon single crystals is investigated by positron lifetime measurements. Anodization at constant current induces changes in the positron lifetime spectrum of monocrystalline silicon samples. It is found that theses changes are primarily dependent on the silicon resistivity. The annihilation parameter behaviour of anodized samples, treated at high temperature under reducing conditions, is also investigated. The results reveal that positron annihilation can be a useful technique to characterize porous silicon formed by anodizing as well as to investigate its thermal behaviour. (author)

  7. New Developments in Positron Scintigraphy and the Application of Cyclotron-Produced Positron Emitters

    Energy Technology Data Exchange (ETDEWEB)

    Brownell, G. L.; Burnham, C. A.; Wilensky, S.; Aronow, S.; Kazemi, H.; Strieder, D. [Massachusetts General Hospital. Boston, MA (United States)

    1969-01-15

    The use of positron-emitting radioisotopes offers unique advantages inscintigraphy and dynamic function studies. The detection of the two annihilation quanta provides, in principle, the possibility of utilization of all the positron annihilations with good resolution. In practice, very high efficiencies can be achieved with large area annihilation quanta detectors. The use of multi-detector matrices as large area detectors permits high levels o f activity and yields very high data acquisition rates. The independence of attenuation with depth of a source offers marked advantages for quantitative measurement. The use of time-of-flight techniques opens the possibility of true three-dimensional visualization. Finally, a number of very short-lived positron emitting radioisotopes such as {sup 15}O, {sup 19}N and {sup 11}C are available. A hybrid positron scanner has been constructed and is undergoing tests for brain tumour localization using {sup 74}As. The scanner uses two rows of detectors each containing 9 Nal scintillators and phototubes. The detector array moves continuously in the horizontal direction and in steps in the vertical direction, producing a scintigram with no line structure. The data is recorded on tape for replay or for computer processing. In either case, the plane of best focus can be positioned at will. The techniques developed for the hybrid scanner will be used in a stationary device employing two two-dimensional arrays of detectors. The design will emphasize the very rapid collection of data and the sequential production of scintigrams. The advantages and techniques of positron annihilation detection are also applicable to devices for study of dynamic function. We have constructed and are testing a fast six-detector coincidence system for pulmonary function studies. The measurement of time-of-flight offers the possibility of three-dimensional visualization of a distribution of positron-emitting radioisotope. We a re studying systems with

  8. Techniques for slow positron beam generation and the applications

    International Nuclear Information System (INIS)

    Okada, Sohei

    1994-01-01

    Slow positron beams have been expected to be a powerful tool for observation of nature in wide range of research fields from materials science to basic physics, chemistry and biology. In this paper, at first, the beam technology is reviewed, which includes the positron generation, the transformation to slow positron beams and the beam manipulation such as beam stretching, bunching and brightness enhancement. Next, the present status of the slow positron beam applications to a variety of fields is demonstrated in terms of special characteristics of positron, that is, depth controllability, surface sensitivity, unique ionization channels and elemental anti-particle properties. Finally, prospects to produce intense slow positron beams are described. (author) 65 refs

  9. Positron emission tomography

    CERN Document Server

    Paans, A M J

    2006-01-01

    Positron Emission Tomography (PET) is a method for measuring biochemical and physiological processes in vivo in a quantitative way by using radiopharmaceuticals labelled with positron emitting radionuclides such as 11C, 13N, 15O and 18F and by measuring the annihilation radiation using a coincidence technique. This includes also the measurement of the pharmacokinetics of labelled drugs and the measurement of the effects of drugs on metabolism. Also deviations of normal metabolism can be measured and insight into biological processes responsible for diseases can be obtained. At present the combined PET/CT scanner is the most frequently used scanner for whole-body scanning in the field of oncology.

  10. Low-energy positron interactions with atoms and molecules

    International Nuclear Information System (INIS)

    Surko, C M; Gribakin, G F; Buckman, S J

    2005-01-01

    This paper is a review of low-energy positron interactions with atoms and molecules. Processes of interest include elastic scattering, electronic and vibrational excitation, ionization, positronium formation and annihilation. An overview is presented of the currently available theoretical and experimental techniques to study these phenomena, including the use of trap-based positron beam sources to study collision processes with improved energy resolution. State-resolved measurements of electronic and vibrational excitation cross sections and measurement of annihilation rates in atoms and molecules as a function of incident positron energy are discussed. Where data are available, comparisons are made with analogous electron scattering cross sections. Resonance phenomena, common in electron scattering, appear to be less common in positron scattering. Possible exceptions include the sharp onsets of positron-impact electronic and vibrational excitation of selected molecules. Recent energy-resolved studies of positron annihilation in hydrocarbons containing more than a few carbon atoms provide direct evidence that vibrational Feshbach resonances underpin the anomalously large annihilation rates observed for many polyatomic species. We discuss open questions regarding this process in larger molecules, as well as positron annihilation in smaller molecules where the theoretical picture is less clear. (topical review)

  11. Probing the defects in nano-semiconductors using positrons

    Energy Technology Data Exchange (ETDEWEB)

    Nambissan, P M G, E-mail: pmg.nambissan@saha.ac.in [Nuclear and Atomic Physics Division, Saha Institute of Nuclear Physics, 1/AF Bidhannagar, Kolkata 700064 (India)

    2011-01-10

    Positron annihilation spectroscopy (PAS) is a very useful tool to study the defect properties of nanoscale materials. The ability of thermalized positrons to diffuse over to the surfaces of nanocrystallites prior to annihilation helps to explore the disordered atomic arrangement over there and is very useful in understanding the structure and properties of nanomaterials. As examples, the results of studies on FeS{sub 2} nanorods and ZnS nanoparticles are presented. In semiconductor nanoparticles, there are positron trapping sites within the grains also and these are characterised by using appropriate models on the measured positron lifetimes. We have observed vivid changes in the measured positron lifetimes and Doppler broadened gamma ray spectral lineshapes during structural transformations prompted by substitutional effects in Mn{sup 2+}-doped ZnS nanorods. Interestingly, the nanoparticles did not exhibit the transformation, implying the morphologies of the nanosystems playing a decisive role. Quantum confinement effect in CdS nanoparticles was another phenomenon that could be seen through positron annihilation experiments. Coincidence Doppler broadening measurements have been useful to identify the elemental environment around the vacancy clusters that trap positrons. Recent studies on nanocrystalline oxide and sulphide semiconductors are also discussed.

  12. Probing the defects in nano-semiconductors using positrons

    International Nuclear Information System (INIS)

    Nambissan, P M G

    2011-01-01

    Positron annihilation spectroscopy (PAS) is a very useful tool to study the defect properties of nanoscale materials. The ability of thermalized positrons to diffuse over to the surfaces of nanocrystallites prior to annihilation helps to explore the disordered atomic arrangement over there and is very useful in understanding the structure and properties of nanomaterials. As examples, the results of studies on FeS 2 nanorods and ZnS nanoparticles are presented. In semiconductor nanoparticles, there are positron trapping sites within the grains also and these are characterised by using appropriate models on the measured positron lifetimes. We have observed vivid changes in the measured positron lifetimes and Doppler broadened gamma ray spectral lineshapes during structural transformations prompted by substitutional effects in Mn 2+ -doped ZnS nanorods. Interestingly, the nanoparticles did not exhibit the transformation, implying the morphologies of the nanosystems playing a decisive role. Quantum confinement effect in CdS nanoparticles was another phenomenon that could be seen through positron annihilation experiments. Coincidence Doppler broadening measurements have been useful to identify the elemental environment around the vacancy clusters that trap positrons. Recent studies on nanocrystalline oxide and sulphide semiconductors are also discussed.

  13. Probing the defects in nano-semiconductors using positrons

    Science.gov (United States)

    Nambissan, P. M. G.

    2011-01-01

    Positron annihilation spectroscopy (PAS) is a very useful tool to study the defect properties of nanoscale materials. The ability of thermalized positrons to diffuse over to the surfaces of nanocrystallites prior to annihilation helps to explore the disordered atomic arrangement over there and is very useful in understanding the structure and properties of nanomaterials. As examples, the results of studies on FeS2 nanorods and ZnS nanoparticles are presented. In semiconductor nanoparticles, there are positron trapping sites within the grains also and these are characterised by using appropriate models on the measured positron lifetimes. We have observed vivid changes in the measured positron lifetimes and Doppler broadened gamma ray spectral lineshapes during structural transformations prompted by substitutional effects in Mn2+-doped ZnS nanorods. Interestingly, the nanoparticles did not exhibit the transformation, implying the morphologies of the nanosystems playing a decisive role. Quantum confinement effect in CdS nanoparticles was another phenomenon that could be seen through positron annihilation experiments. Coincidence Doppler broadening measurements have been useful to identify the elemental environment around the vacancy clusters that trap positrons. Recent studies on nanocrystalline oxide and sulphide semiconductors are also discussed.

  14. Descriptions of positron defect analysis capabilities

    International Nuclear Information System (INIS)

    Howell, R.H.

    1994-10-01

    A series of descriptive papers and graphics appropriate for distribution to potential collaborators has been assembled. These describe the capabilities for defect analysis using positron annihilation spectroscopy. The application of positrons to problems in the polymer and semiconductor industries is addressed

  15. Positron annihilation studies on high temperature superconductors

    International Nuclear Information System (INIS)

    Sundar, C.S.; Bharathi, A.

    1996-01-01

    A survey of the positron annihilation studies on high temperature superconductors (HTSC), with results drawn mainly from our work, is presented. These include results of the studies on the temperature dependence of positron lifetime across T c , which have been carried out in the whole gamut of oxide superconductors. These experimental results are discussed in conjunction with the results of theoretically calculated positron density distribution, and it is shown that the observed temperature dependence of lifetime is intimately linked to the probing of the Cu-O network by the positrons. Results on the investigation of oxygen defects, which play a crucial role in HTSC, are presented. The most significant contribution of positrons to HTSC relates to the investigation of Fermi surface and the results of these studies, drawn from literature, are indicated. Some of our recent results in other novel superconducting materials, viz., the fullerenes and borocarbides are also presented. (author). 69 refs., 15 figs

  16. Electron-positron correlations in an electron liquid

    International Nuclear Information System (INIS)

    Stachowiak, H.

    1980-01-01

    The importance of studying electron-positron interaction for the interpretation of angular correlation data obtained for metallic systems is emphasized. The most successful approaches to electron-positron correlations in jellium are presented. Those include the Bethe-Goldstone two-body equation proposed by Kahana, the charge-density-dielectric function approach connected with the names of Singwi, Sjolander, Stott and Bhattacharyya and the Sawada boson-generalized Tamm-Dancoff approach elaborated recently by Arponen and Pajanne. In conclusion, it is reported that one can consider that the behaviour of a positron at rest in jellium is relatively well understood, though the problem of the optimal choice of a two-body electron-positron phenomenological equation is still open. Also, the behaviour of a positron in a real metal is not well understood and so far, serious calculations in this field have been performed only on very simple models while realistic calculations of the ACPAQ curves tend to minimize the importance of the problems which remain to be solved. (K.B.)

  17. Development of positron emitting radionuclides for imaging with improved positron detectors

    International Nuclear Information System (INIS)

    Yano, Y.

    1976-10-01

    Recent advances in positron cameras and positron ring detectors for transverse section reconstruction have created renewed interest in positron emitting radionuclides. This paper reports on: generator-produced 82 Rb; cyclotron-produced 62 Zn; and reactor-produced 64 Cu. Investigation of the 82 Sr (25 d)-- 82 Rb (75 s) generator determined the elution characteristics for Bio-Rex 70, a weakly acidic carboxylic cation exchanger, using 2% NaCl as the eluent. The yield of 82 Rb and the breakthrough of 82 Sr were determined for newly prepared columns and for long term elution conditions. Spallation-produced 82 Sr was used to charge a compact 82 Rb generator to obtain multi-millicurie amounts of 82 Rb for myocardial imaging. Zinc accumulates in the islet cells of the pancreas and in the prostate. Zinc-62 was produced by protons on Cu foil and separated by column chromatography. Zinc-62 was administered as the amino acid chelates and as the ZnCl 2 to tumor and normal animals. Tissue distribution was determined for various times after intravenous injection. Pancreas-liver images of 62 Zn-histidine uptake were obtained in animals with the gamma camera and the liver uptake of /sup 99m/Tc sulfur colloid was computer subtracted to image the pancreas alone. The positron camera imaged uptake of 62 Zn-histidine in the prostate of a dog at 20 h. 64 Cu was chelated to asparagine, a requirement of leukemic cells, and administered to lymphoma mice. Uptake in tumor and various tissues was determined and compared with the uptake of 67 Ga citrate under the same conditions. 64 Cu-asparagine had better tumor-to-soft tissue ratios than 67 Ga-citrate

  18. Preliminary Conceptual Design Report for the FACET-II Project at SLAC National Accelerator Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Hogan, Mark [SLAC National Accelerator Lab., Menlo Park, CA (United States)

    2016-04-22

    Plasma wakefield acceleration has the potential to dramatically shrink the size and cost of particle accelerators. Research at the SLAC National Accelerator Laboratory has demonstrated that plasmas can provide 1,000 times the acceleration in a given distance compared with current technologies. Developing revolutionary and more efficient acceleration techniques that allow for an affordable high-energy collider is the focus of FACET, a National User Facility at SLAC. The existing FACET National User Facility uses part of SLAC’s two-mile-long linear accelerator to generate high-density beams of electrons and positrons. FACET-II is a new test facility to develop advanced acceleration and coherent radiation techniques with high-energy electron and positron beams. It is the only facility in the world with high energy positron beams. FACET-II provides a major upgrade over current FACET capabilities and the breadth of the potential research program makes it truly unique. It will synergistically pursue accelerator science that is vital to the future of both advanced acceleration techniques for High Energy Physics, ultra-high brightness beams for Basic Energy Science, and novel radiation sources for a wide variety of applications. The design parameters for FACET-II are set by the requirements of the plasma wakefield experimental program. To drive the plasma wakefield requires a high peak current, in excess of 10kA. To reach this peak current, the electron and positron design bunch size is 10μ by 10μ transversely with a bunch length of 10μ. This is more than 200 times better than what has been achieved at the existing FACET. The beam energy is 10 GeV, set by the Linac length available and the repetition rate is up to 30 Hz. The FACET-II project is scheduled to be constructed in three major stages. Components of the project discussed in detail include the following: electron injector, bunch compressors and linac, the positron system, the Sector 20 sailboat and W chicanes

  19. Positron Spectroscopy of Hydrothermally Grown Actinide Oxides

    Science.gov (United States)

    2014-03-27

    actinide oxides . The work described here is an attempt to characterize the quality of crystals using positron annihilation spectroscopy (PALS). The...Upadhyaya, R. V. Muraleedharan, B. D. Sharma and K. G. Prasad, " Positron lifetime studies on thorium oxide powders," Philosohical Magazine A, vol. 45... crystals . A strong foundation for actinide PALS studies was laid, but further work is required to build a more effective system. Positron Spectroscopy

  20. Positron beam studies of solids and surfaces: A summary

    International Nuclear Information System (INIS)

    Coleman, P.G.

    2006-01-01

    A personal overview is given of the advances in positron beam studies of solids and surfaces presented at the 10th International Workshop on Positron Beams, held in Doha, Qatar, in March 2005. Solids studied include semiconductors, metals, alloys and insulators, as well as biophysical systems. Surface studies focussed on positron annihilation-induced Auger electron spectroscopy (PAES), but interesting applications of positron-surface interactions in fields as diverse as semiconductor technology and studies of the interstellar medium serve to illustrate once again the breadth of scientific endeavour covered by slow positron beam investigations

  1. Positron beam studies of solids and surfaces: A summary

    Science.gov (United States)

    Coleman, P. G.

    2006-02-01

    A personal overview is given of the advances in positron beam studies of solids and surfaces presented at the 10th International Workshop on Positron Beams, held in Doha, Qatar, in March 2005. Solids studied include semiconductors, metals, alloys and insulators, as well as biophysical systems. Surface studies focussed on positron annihilation-induced Auger electron spectroscopy (PAES), but interesting applications of positron-surface interactions in fields as diverse as semiconductor technology and studies of the interstellar medium serve to illustrate once again the breadth of scientific endeavour covered by slow positron beam investigations.

  2. Low-energy positron-argon collisions by using parameter-free positron correlation polarization potentials

    International Nuclear Information System (INIS)

    Jain, A.

    1990-01-01

    We report differential, integral, and momentum-transfer cross sections and the scattering length (A 0 ) for positron (e + )-argon scattering at low energies below the positronium formation threshold. An optical-potential approach is employed in which the repulsive Coulombic interaction is calculated exactly at the Hartree-Fock level and the attractive polarization and correlation effects are included approximately via a parameter-free positron correlation polarization (PCP) potential recently proposed by us. The PCP model is based on the correlation energy var-epsilon corr of one positron in a homogeneous electron gas; in the outside region, the var-epsilon corr is joined smoothly with the correct asymptotic form of the polarization interaction (-α 0 /2r 4 , where α 0 is the target polarizability) where they cross each other for the first time. The total optical potential of the e + -argon system is treated exactly in a partial-wave analysis to extract the scattering parameters. It is found that the PCP potential gives much better qualitative results, particularly for the differential cross sections and the scattering length, than the corresponding results obtained from an electron polarization potential used as such for the positron case. We also discuss the ''critical'' points (representing the minima in the differential scattering) in the low-energy e + -Ar scattering. The present results involve no fitting procedure

  3. Binding matter with antimatter: the covalent positron bond.

    Science.gov (United States)

    Charry, Jorge Alfonso; Varella, Marcio T Do N; Reyes, Andrés

    2018-05-16

    We report sufficient theoretical evidence of the energy stability of the e⁺H₂²⁻ molecule, formed by two H⁻ anions and one positron. Analysis of the electronic and positronic densities of the latter compound undoubtedly points out the formation of a positronic covalent bond between the otherwise repelling hydride anions. The lower limit for the bonding energy of the e⁺H₂²⁻ molecule is 74 kJ/mol (0.77 eV), accounting for the zero-point vibrational correction. The formation of a non electronic covalent bond is fundamentally distinct from positron attachment to stable molecules, as the latter process is characterized by a positron affinity, analogous to the electron affinity. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Positron annihilation spectroscopy using high-energy photons

    International Nuclear Information System (INIS)

    Butterling, Maik; Jungmann, Marco; Krause-Rehberg, Reinhard; Krille, Arnold; Anwand, Wolfgang; Brauer, Gerhard; Cowan, Thomas E.; Hartmann, Andreas; Kosev, Krasimir; Schwengner, Ronald; Wagner, Andreas

    2010-01-01

    The superconducting electron accelerator ELBE (Electron Linac with high Brilliance and low Emittance) at the Research Centre Dresden-Rossendorf (Germany) serves as a high-intensity bremsstrahlung photon-source delivering a pulsed beam (26 MHz) with very short bunches (<5 ps). The photons are being converted into positrons by means of pair production inside the target material thus forming an intense positron source. The accelerator machine pulse is used as time reference allowing positron lifetime spectroscopy. We performed positron annihilation spectroscopy by pair production in different sample materials and used coincidence techniques to reduce the background due to scattered photons significantly in order resulting in spectra of extraordinary high quality. (Abstract Copyright [2010], Wiley Periodicals, Inc.)

  5. Polymeric membrane studied using slow positron beam

    International Nuclear Information System (INIS)

    Hung, W.-S.; Lo, C.-H.; Cheng, M.-L.; Chen Hongmin; Liu Guang; Chakka, Lakshmi; Nanda, D.; Tung, K.-L.; Huang, S.-H.; Lee, Kueir-Rarn; Lai, J.-Y.; Sun Yiming; Yu Changcheng; Zhang Renwu; Jean, Y.C.

    2008-01-01

    A radioisotope slow positron beam has been built at the Chung Yuan Christian University in Taiwan for the research and development in membrane science and technology. Doppler broadening energy spectra and positron annihilation lifetime have been measured as a function of positron energy up to 30 keV in a polyamide membrane prepared by the interfacial polymerization between triethylenetetraamine (TETA) and trimesoyl chloride (TMC) on modified porous polyacrylonitrile (PAN) asymmetric membrane. The multilayer structures and free-volume depth profile for this asymmetric membrane system are obtained. Positron annihilation spectroscopy coupled with a slow beam could provide new information about size selectivity of transporting molecules and guidance for molecular designs in polymeric membranes

  6. A Magnetic Transport Middle Eastern Positron Beam

    International Nuclear Information System (INIS)

    Al-Qaradawi, I.Y.; Britton, D.T.; Rajaraman, R.; Abdulmalik, D.

    2008-01-01

    A magnetically guided slow positron beam is being constructed at Qatar University and is currently being optimised for regular operation. This is the first positron beam in the Middle East, as well as being the first Arabic positron beam. Novel features in the design include a purely magnetic in-line deflector, working in the solenoid guiding field, to eliminate un-moderated positrons and block the direct line of sight to the source. The impact of this all-magnetic transport on the Larmor radius and resultant beam characteristics are studied by SIMION simulations for both ideal and real life magnetic field variations. These results are discussed in light of the coupled effect arising from electrostatic beam extraction

  7. Characteristics of the positron annihilation process in the matter

    International Nuclear Information System (INIS)

    Dryzek, J.

    2000-01-01

    In this report the positrons annihilation spectroscopy, as a method for the matter study is described. The interaction of positrons of high as well as thermal energies are discussed and different models of mentioned interactions are presented. Special attention is paid for positrons interaction with crystal lattice and its defects. The influence of positron beams characteristics on measured values are also discussed

  8. Positron annihilation studies on high temperature superconductors

    International Nuclear Information System (INIS)

    Sundar, C.S.; Bharathi, A.

    1991-01-01

    The results of positron annihilation measurements as a function of temperature, across Tc, in a variety of high temperature superconductors such as Y-Ba-Cu-O (Y1237), Y-Ba-Cu-O (Y1248), Bi-Sr-Ca-Cu-O, Tl-Ba-Ca-Cu-O, Ba-K-Bi-O and Nd-Ce-Cu-O are presented. It is shown that the variation of annihilation parameters in the superconducting state is correlated with the diposition of the positron density distribution with respect to the superconducting CuO planes. An increase in positron lifetime is observed below Tc when the positrons probe the CuO planes whereas a decrease in lifetime is observed when the positron density overlaps predominantly with the apical oxygen atom. With this correlation, the different temperature variation of annihilation parameters, seen in the various high temperature superconductors, is understood in terms of a local charge transfer from the planar oxygen atom to the apical oxygen atom. The significance of these results in the context of various theoretical models of high temperature superconductivity is discussed. In addition, the application of positron annihilation spectroscopy to the study of oxygen defects in the Y-Ba-Cu-O, Bi-Sr-Ca-Cu-O and Nd-Ce-Cu-O is presented. (author). 53 refs., 17 figs., 2 tabs

  9. Radiation damage analysis by positron annihilation spectroscopy

    International Nuclear Information System (INIS)

    Siegel, R.W.

    1982-01-01

    Positron annihilation spectroscopy (PAS) has in recent years become a valuable new tool for investigating defects in metals. The ability of the positron to localize in a trapped state at various defect sites, in which the positron annihilates with unique characteristics, has enabled the positron to be used as a localized probe of these defect sites. Several reviews of the application of PAS to the study of defects in metals have been published, as have more general treatises on the applications of positron annihilation to the study of solids. PAS has made, and has considerably greater potential for, a significant contribution to radiation damage analysis in two areas of importance: (1) the determination of atomic-defect properties, a knowledge of which is necessary for the modeling required to couple the results of model experiments using electron and ion irradiation with the expected irradiation conditions of reactor systems, and (2) the monitoring and characterization of irradiation-induced microstructure development. A unique aspect of PAS for radiation damage analysis is the defect specificity of the annihilation characteristics of a trapped positron. In addition to its value as an independent analytical tool, PAS can be a useful complement to more traditional techniques for defect studies

  10. Use of fluorine-18 fluorodeoxyglucose positron emission tomography in the detection of silent metastases from malignant melanoma

    DEFF Research Database (Denmark)

    Jakobsen, Annika Loft; Andersson, A P; Dahlstrøm, K

    2000-01-01

    Correct staging is crucial for the management and prognosis of patients with malignant melanoma. The aim of this prospective study was to compare staging by whole-body positron emission tomography using fluorine-18 fluorodeoxyglucose (18F-FDG) with staging by conventional methods. Thirty......-eight patients with malignant melanoma of clinical stage II (local recurrence, in-transit and regional lymph node metastases) or III (metastases to other sites than in stage II) were included in the study. The results of the PET scans were compared with those obtained by clinical examination, computed tomography...

  11. Polarization Study for NLC Positron Source Using EGS4

    Energy Technology Data Exchange (ETDEWEB)

    Liu, James C

    2000-09-20

    SLAC is exploring a polarized positron source to study new physics for the NLC project. The positron source envisioned in this paper consists of a polarized electron source, a 50-MeV electron accelerator, a thin target less-than-or-equal-to 0.2 radiation length for positron production, and a capture system for high-energy, small angular divergence positrons. The EGS4 code was used to study the yield, energy spectra, emission-angle distribution, and the mean polarization of the positrons emanating from W-Re and Ti targets hit by longitudinally polarized electron and photon beams. To account for polarization within the EGS4 code a method devised by Flottmann was used, which takes into account polarization transfer for pair production, bremsstrahlung, and Compton interactions. A mean polarization of 0.85 for positrons with energies greater than 25 MeV was obtained. Most of the high-energy positrons were emitted within a forward angle of 20 degrees. The yield of positrons above 25 MeV per incident photon was 0.034, which was about 70 times higher than that obtained with an electron beam.

  12. Generation of an intense pulsed positron beam and its applications

    International Nuclear Information System (INIS)

    Suzuki, Ryoichi; Mikado, Tomohisa; Ohgaki, Hideaki; Chiwaki, Mitsukuni; Yamazaki, Tetsuo; Kobayashi, Yoshinori.

    1994-01-01

    A positron pulsing system for an intense positron beam generated by an electron linac has been developed at the Electrotechnical Laboratory. The pulsing system generates an intense pulsed positron beam of variable energy and variable pulse period. The pulsed positron beam is used as a non destructive probe for various materials researches. In this paper, we report the present status of the pulsed positron beam and its applications. (author)

  13. Matrix Isolation Spectroscopy Applied to Positron Moderatioin in Cryogenic Solids

    Science.gov (United States)

    2011-07-01

    Current Positron Applications • 2-γ decay exploited in Positron Emission Tomography (PET) scanners. • Positrons localize & annihilate preferentially at...Air Force  Eglin Air Force Base AFRL-RW-EG-TP-2011-024 Matrix Isolation Spectroscopy Applied to Positron Moderation in Cryogenic Solids Distribution... Spectroscopy Applied to Positron Moderation in Cryogenic Solids 5a. CONTRACT NUMBER 5b. GRANT NUMBER 62602F 5c. PROGRAM ELEMENT NUMBER 6

  14. Positron annihilation spectroscopy: Applications to Si, ZnO, and multilayer semiconductor structures

    Science.gov (United States)

    Schaffer, J. P.; Rohatgi, A.; Dewald, A. B.; Frost, R. L.; Pang, S. K.

    1989-11-01

    The potential of positron annihilation spectroscopy (PAS) for defect characterization at the atomic scale in semiconductors is demonstrated for Si, ZnO, and multilayer structures, such as an AlGaAs/GaAs solar cell. The types of defects discussed include: i) vacancy complexes, oxygen impurities and dopants, ii) the influence of cooling rates on spatial non-uniformities in defects, and iii) characterization of buried interfaces. In sev-eral instances, the results of the PAS investigations are correlated with data from other established semiconductor characterization techniques.

  15. Advanced characterization of lithium battery materials with positrons

    International Nuclear Information System (INIS)

    Barbiellini, Bernardo; Kuriplach, Jan

    2017-01-01

    Cathode materials are crucial to improved battery performance, in part because there are not yet materials that can maintain high power and stable cycling with a capacity comparable to that of anode materials. Our parameter-free, gradient-corrected model for electron-positron correlations predicts that spectroscopies based on positron annihilation can be deployed to study the effect of lithium intercalation in the oxide matrix of the cathode. The positron characteristics in oxides can be reliably computed using methods based on first-principles. Thus, we can enable a fundamental characterization of lithium battery materials involving positron annihilation spectroscopy and first-principles calculations. The detailed information one can extract from positron experiments could be useful for understanding and optimizing both battery materials and bi-functional catalysts for oxygen reduction and evolution. (paper)

  16. Defects in Czochralski-grown silicon crystals investigated by positron annihilation

    Energy Technology Data Exchange (ETDEWEB)

    Ikari, Atsushi; Kawakami, Kazuto; Haga, Hiroyo [Nippon Steel Corp., Sagamihara, Kanagawa (Japan). Electronics Research Labs.; Uedono, Akira; Wei, Long; Kawano, Takao; Tanigawa, Shoichiro

    1994-10-01

    Positron lifetime and Doppler broadening experiments were performed on Czochralski-grown silicon crystals. A monoenergetic positron beam was also used to measure the diffusion length of positrons in the wafer. From the measurements, it was observed that the value of diffusion length of positrons decreased at the region where microdefects were formed during the crystal growth process. It was also found that the line shape parameter S decreased and the lifetime of positrons increased at the region. These results can be attributed to the annihilation of positrons trapped by vacancy oxygen complexes which are formed in association with the microdefects. (author).

  17. Stress evaluation at the ILC positron source

    Energy Technology Data Exchange (ETDEWEB)

    Ushakov, Andriy; Moortgat-Pick, Gudrid [Universitaet Hamburg, II. Institut fuer Theoretische Physik, Luruper Chaussee 149, 22761 Hamburg (Germany); Riemann, Sabine; Dietrich, Felix [Deutsches Elektronen-Synchrotron (DESY), Standort Zeuthen, Platanenallee 6, 15738 Zeuthen (Germany); Aulenbacher, Kurt; Tyukin, Valery; Heil, Philipp [Johannes Gutenberg-Universitaet Mainz, Institut fuer Kernphysik, Johann-Joachim-Becher-Weg 45, 55128 Mainz (Germany)

    2016-07-01

    High luminosity is required at future Linear Colliders which is particularly challenging for all corresponding positron sources. At the International Linear Collider (ILC), polarized positrons are obtained from electron-positron pairs by converting high-energy photons produced by passing the high-energy main electron beam through a helical undulator. The conversion target undergoes cyclic stress with high peak values. To distribute the thermal load, the target is designed as wheel spinning in vacuum with 100 m/s. However, the cyclic stress over long time at high target temperatures could exceed the fatigue stress limit. In the talk, an overview of the ILC positron source is given. The prospects to study material parameters under conditions as expected at the ILC are discussed.

  18. Ionization and positron emission in giant quasiatoms

    International Nuclear Information System (INIS)

    Soff, G.; Reinhardt, J.; Reus, T. de; Wietschorke, K.H.; Schaefer, A.; Mueller, B.; Greiner, W.; Mueller, U.; Schlueter, P.

    1985-07-01

    Electron excitation processes in superheavy quasiatoms are treated within a relativistic framework. Theoretical results on K-hole production rates as well as delta-electron and positron spectra are compared with experimental data. It is demonstrated that the study of heavy ion collisions with nuclear time delay promises a signature for the spontaneous positron formation in overcritical systems. Corresponding experimental results are confronted with our theoretical hypothesis. Recent speculations on the origin of the observed peak structures in positron spectra are critically reviewed. Atomic excitations are also employed to obtain information on the course of a nuclear reaction. Using a semiclassical picture we calculate the emission of delta-electrons and positrons in deep-inelastic nuclear reactions. Furthermore some consequences of conversion processes in giant systems are investigated. (orig.)

  19. Development of a Simple Positron Age-Momentum Setup

    Science.gov (United States)

    Sheffield, Thomas; Quarles, C. A.

    2009-04-01

    A positron age-momentum setup that uses NIM Bin electronic modules and a conventional multichannel analyzer (MCA) is described. The essential idea is to accumulate a Doppler broadened spectrum (sensitive to the annihilation electron momentum) using a high purity Germanium detector in coincidence with a BaF2 scintillation counter, which also serves as the stop signal in a conventional positron lifetime setup. The MCA that collects the Doppler spectrum is gated by a selected region of the lifetime spectrum. Thus we can obtain Doppler broadening spectra as a function of positron lifetime: an age-momentum spectrum. The apparatus has been used so far to investigate a ZnO sample where the size of different vacancy trapping sites may affect the positron lifetime and the Doppler broadening spectrum. We are also looking at polymer and rubber carbon-black composite samples where differences in the Doppler spectrum may arise from positron trapping or positronium formation in the samples. Correction for background and contribution from the positron source itself to the Doppler spectrum will be discussed.

  20. Channeling crystals for positron production

    International Nuclear Information System (INIS)

    Decker, F.J.

    1991-05-01

    Particles traversing at small angles along a single crystal axis experience a collective scattering force of many crystal atoms. The enormous fields can trap the particles along an axis or plane, called channeling. High energy electrons are attracted by the positive nuclei and therefore produce strongly enhanced so called coherent bremsstrahlung and pair production. These effects could be used in a positron production target: A single tungsten crystal is oriented to the incident electron beam within 1 mrad. At 28 GeV/c the effective radiation length is with 0.9 mm about one quarter of the amorphous material. So the target length can be shorter, which yields a higher conversion coefficient and a lower emittance of the positron beam. This makes single crystals very interesting for positron production targets. 18 refs., 2 figs

  1. Positron spectroscopy for materials characterization

    International Nuclear Information System (INIS)

    Schultz, P.J.; Snead, C.L. Jr.

    1988-01-01

    One of the more active areas of research on materials involves the observation and characterization of defects. The discovery of positron localization in vacancy-type defects in solids in the 1960's initiated a vast number of experimental and theoretical investigations which continue to this day. Traditional positron annihilation spectroscopic techniques, including lifetime studies, angular correlation, and Doppler broadening of annihilation radiation, are still being applied to new problems in the bulk properties of simple metals and their alloys. In addition new techniques based on tunable sources of monoenergetic positron beams have, in the last 5 years, expanded the horizons to studies of surfaces, thin films, and interfaces. In the present paper we briefly review these experimental techniques, illustrating with some of the important accomplishments of the field. 40 refs., 19 figs

  2. 50 years of positrons

    International Nuclear Information System (INIS)

    Anon.

    1982-01-01

    This year marks the 50th anniversary of one of the major landmarks of modern physics - the discovery of the positron, the antimatter counterpart of the electron. This provided the first evidence for antimatter, and it was also unprecedented for the existence of a new particle to have been predicted by theory. The positron and the concepts behind it were to radically change our picture of Nature. It led to the rapid advancement or our understanding, culminating some fifteen years later with the formulation of quantum electrodynamics as we now know it. (orig./HSI).

  3. Positron studies of defected metals, metallic surfaces. Final report, July 1, 1985--December 1, 1991

    Energy Technology Data Exchange (ETDEWEB)

    Bansil, A.

    1991-12-31

    Specific problems proposed under this project included the treatment of electronic structure and momentum density in various disordered and defected systems. Since 1987, when the new high-temperature superconductors were discovered, the project focused extensively on questions concerning the electronic structure and Fermiology of high-{Tc} superconductors, in particular, (i) momentum density and positron experiments, (ii) angle-resolved photoemission intensities, (iii) effects of disorder and substitutions in the high-{Tc}`s.

  4. Positron annihilation in metallic glasses - a general survey

    International Nuclear Information System (INIS)

    Brauer, G.; Kajcsos, Zs.; Kemeny, T.

    1981-08-01

    This report presents a review of the literature on positron annihilation studies concerning metallic glasses. After some general information and overview on structural models of metallic glasses as well as a short description of the positron annihilation method itself are added. Conclusions regarding information on the structure of metallic glasses obtainable by positron annihilation are also given. (author)

  5. PREFACE: The International Workshop on Positron Studies of Defects 2014

    Science.gov (United States)

    Sugita, Kazuki; Shirai, Yasuharu

    2016-01-01

    The International Workshop on Positron Studies of Defects 2014 (PSD-14) was held in Kyoto, Japan from 14-19 September, 2014. The PSD Workshop brought together positron scientists interested in studying defects to an international platform for presenting and discussing recent results and achievements, including new experimental and theoretical methods in the field. The workshop topics can be characterized as follows: • Positron studies of defects in semiconductors and oxides • Positron studies of defects in metals • New experimental methods and equipment • Theoretical calculations and simulations of momentum distributions, positron lifetimes and other characteristics for defects • Positron studies of defects in combination with complementary methods • Positron beam studies of defects at surfaces, interfaces, in sub-surface regions and thin films • Nanostructures and amorphous materials

  6. Positron annihilation in germanium in thermal equilibrium at high temperature

    Energy Technology Data Exchange (ETDEWEB)

    Uedono, Akira; Moriya, Tsuyoshi; Komuro, Naoyuki; Tanigawa, Shoichiro [Tsukuba Univ., Ibaraki (Japan). Inst. of Materials Science; Kawano, Takao; Ikari, Atsushi

    1996-09-01

    Annihilation characteristics of positrons in Ge in thermal equilibrium at high temperature were studied using a monoenergetic positron beam. Precise measurements of Doppler broadening profiles of annihilation radiation were performed in the temperature range between 300 K and 1211 K. The line shape parameters of Doppler broadening profiles were found to be almost constant at 300-600 K. The changes in these parameters were observed to start above 600 K. This was attributed to both the decrease in the fraction of positrons annihilating with core electrons and the lowering of the crystal symmetry around the region detected by positron-electron pairs. This suggests that behaviors of positrons are dominated by some form of positron-lattice coupling in Ge at high temperatures. The temperature dependence of the diffusion length of positrons was also discussed. (author)

  7. A simulation study of a method to reduce positron annihilation spread distributions using a strong magnetic field in positron emission tomography

    International Nuclear Information System (INIS)

    Iida, H.; Kanno, I.; Miura, S.; Murakami, M.; Takahashi, V.; Kemura, K.

    1986-01-01

    The positron trajectories have been three-dimensionally simulated using a Monte-Carlo method under various strength of the magnetic field. More than 5 tesla of the field confined the positrons effectively, resulting in increase of the probability of the annihilation within a limited small region, hence the higher spatial resolution in positron emission tomography

  8. Formation of a high intensity low energy positron string

    Science.gov (United States)

    Donets, E. D.; Donets, E. E.; Syresin, E. M.; Itahashi, T.; Dubinov, A. E.

    2004-05-01

    The possibility of a high intensity low energy positron beam production is discussed. The proposed Positron String Trap (PST) is based on the principles and technology of the Electron String Ion Source (ESIS) developed in JINR during the last decade. A linear version of ESIS has been used successfully for the production of intense highly charged ion beams of various elements. Now the Tubular Electron String Ion Source (TESIS) concept is under study and this opens really new promising possibilities in physics and technology. In this report, we discuss the application of the tubular-type trap for the storage of positrons cooled to the cryogenic temperatures of 0.05 meV. It is intended that the positron flux at the energy of 1-5 eV, produced by the external source, is injected into the Tubular Positron Trap which has a similar construction as the TESIS. Then the low energy positrons are captured in the PST Penning trap and are cooled down because of their synchrotron radiation in the strong (5-10 T) applied magnetic field. It is expected that the proposed PST should permit storing and cooling to cryogenic temperature of up to 5×109 positrons. The accumulated cooled positrons can be used further for various physics applications, for example, antihydrogen production.

  9. Formation of a high intensity low energy positron string

    International Nuclear Information System (INIS)

    Donets, E.D.; Donets, E.E.; Syresin, E.M.; Itahashi, T.; Dubinov, A.E.

    2004-01-01

    The possibility of a high intensity low energy positron beam production is discussed. The proposed Positron String Trap (PST) is based on the principles and technology of the Electron String Ion Source (ESIS) developed in JINR during the last decade. A linear version of ESIS has been used successfully for the production of intense highly charged ion beams of various elements. Now the Tubular Electron String Ion Source (TESIS) concept is under study and this opens really new promising possibilities in physics and technology. In this report, we discuss the application of the tubular-type trap for the storage of positrons cooled to the cryogenic temperatures of 0.05 meV. It is intended that the positron flux at the energy of 1-5 eV, produced by the external source, is injected into the Tubular Positron Trap which has a similar construction as the TESIS. Then the low energy positrons are captured in the PST Penning trap and are cooled down because of their synchrotron radiation in the strong (5-10 T) applied magnetic field. It is expected that the proposed PST should permit storing and cooling to cryogenic temperature of up to 5x10 9 positrons. The accumulated cooled positrons can be used further for various physics applications, for example, antihydrogen production

  10. Application of positron annihilation to polymer and development of a radioisotopes-based pulsed slow positron beam apparatus

    International Nuclear Information System (INIS)

    Suzuki, Takenori

    2004-01-01

    Positrons injected into polymer behave as nanometer probes, which can detect the size and amount of intermolecular spaces among polymer structures. Although positrons can probe the characteristics of polymer, they induce a radiation effect on polymer samples. At low temperature, the radiation effect induces free electrons, which can be trapped in a shallow potential created among intermolecular structures after freezing molecular motions. These trapped electrons can be released after the disappearance of the shallow potential due to the reappearance of molecular motion above the relaxation temperature. Thus, positrons can be used as a probe for relaxation studies. Coincidence of Doppler broadening spectroscopy (CDBS) can improve the S/N ratio to 10 7 , which makes it possible to detect trace elements, since CDBS can separate the high-momentum component of core electrons. A pulsed slow positron beam apparatus is necessary for measuring holes in the polymer film and allows the measurement of the characteristics of thin film coated on semiconductors used widely in electronics industries. (author)

  11. The Optical Design of the PEP-II Injection Beamlines

    CERN Document Server

    Fieguth, T

    1996-01-01

    The optical design of the PEP-II electron and positron Injection Beamlines is described. Use of the existing high power, low emittance beams available from the SLC damping rings require that pulsed extraction of 9.0 GeV electrons and 3.1 GeV positrons for injection into the PEP-II rings occur in the early sectors of the accelerator. More than 5 kilometers of new beam transport lines have been designed and are being constructed to bring these beams to their respective rings. The optical design maximizes the tolerance to errors especially to those contributing to beam size and position jitter. Secondly, the design minimizes costs by utilizing existing components or component designs and minimizing the number required. Here we discuss important attributes including choice of lattice, specification of error tolerances, including errors in construction, alignment, field errors, power supply stability, and orbit correction.

  12. The Optical Design of the PEP-II Injection Beamlines

    Energy Technology Data Exchange (ETDEWEB)

    Fieguth, Ted

    2003-05-23

    The optical design of the PEP-II electron and positron Injection Beamlines is described. Use of the existing high power, low emittance beams available from the SLC damping rings require that pulsed extraction of 9.0 GeV electrons and 3.1 GeV positrons for injection into the PEP-II rings occur in the early sectors of the accelerator. More than 5 kilometers of new beam transport lines have been designed and are being constructed to bring these beams to their respective rings. The optical design maximizes the tolerance to errors especially to those contributing to beam size and position jitter. Secondly, the design minimizes costs by utilizing existing components or component designs and minimizing the number required. Here we discuss important attributes including choice of lattice, specification of error tolerances, including errors in construction, alignment, field errors, power supply stability, and orbit correction.

  13. Ice and Atoms: experiments with laboratory-based positron beams

    International Nuclear Information System (INIS)

    Coleman, P G

    2011-01-01

    This short review presents results of new positron and positronium (Ps) experiments in condensed matter and atomic physics, as an illustration of the satisfying variety of scientific endeavours involving positron beams which can be pursued with relatively simple apparatus in a university laboratory environment. The first of these two studies - on ice films - is an example of how positrons and Ps can provide new insights into an important system which has been widely interrogated by other techniques. The second is an example of how simple positron beam systems can still provide interesting information - here on a current interesting fundamental problem in positron atomic physics.

  14. Positron annihilation studies on nasicon analogues containing cation vacancies

    International Nuclear Information System (INIS)

    Sreeramalu, V.; Sreepad, H.R.; Chandrashekara, A.; Ravindrachary, V.; Gopal, S.

    1990-01-01

    Positron annihilation studies were carried out on the Nasicon analogue Na 2 (La, Al)Zr(PO 4 ) 3 compound for three different concentrations (2.2, 2.8 and 5.2 by wt.%) of ZrO 2 in the nutrient. Angular correlation study of annihilated photons reveals that the defect concentration is maximum for 2.8(wt.%) of ZrO 2 . Further, positron lifetime studies indicate that the positrons are trapped at cation vacancies. Application of a two state trapping model to this system made it possible to evaluate the lifetime of positrons in the Bloch state and of positrons trapped at cation vacancies. (author). 16 refs., 4 figs

  15. Is the positron a light proton. Contrasts of positron/proton analogies in small molecules

    International Nuclear Information System (INIS)

    Cade, P.E.; Kao, C.-M.

    1982-01-01

    The nature of positron behavior in [M - :e + ] systems is explored. Here M - is a molecular anion which combines with a proton to form a stable system, HM. The sharp distinction between the positron and proton dynamics does not entirely remove common characteristics of these systems. Examples are given for HM versus [M - :e + ] systems with M - = (H - , SH - , CN - , and N 3- ). In addition, the possibilities of a 'positronium' bond versus a hydrogen bond are discussed. (Auth.)

  16. Electron-positron pair creation in heavy ion collisions

    International Nuclear Information System (INIS)

    Kienle, P.

    1987-08-01

    We review here the status of experiments to study the electron positron pair creation in heavy ion atom collisions at bombarding energies close to the Coulomb barrier. The disentanglement and characterisation of various sources of positrons observed in such collisions are described with a focus on the monoenergetic electron positron pairs observed. They seem to originate from the two-body decay of a family of neutral particles with masses of about 3 m e and life times in the range of 6x10 -14 s -10 s, produced by high Coulomb fields. First attempts were made to create these particles by resonant Bhabha scattering. First we present some experimental methods for high efficiency positron spectroscopy in heavy ion collisions. Then we describe the discovery of positron creation induced by strong time changing Coulomb fields. (orig./HSI)

  17. The generation and development of the moderators for slow positron beam

    International Nuclear Information System (INIS)

    Yu Weizhong; Yuan Jiaping

    2001-01-01

    The positron annihilation technique is a sensitive tool for studying microdefects and phase transitions in various materials. Usually the energy of positrons is on the order of MeV and the implantation depth about 100 microns, so the bulk average defect density can be studied. In a slow positron beam the positron energy is about keV and the implantation depth a few microns, so surface defects can be detected. Positron moderator is the key device for obtaining a slow positron beam. The authors review the history and development of the positron moderator, including four methods that convert fast positrons into slow mono-energetic positrons and five array types. The tungsten moderator is the most widely used one while the inert gas solid moderator is the most efficient. Field-enhanced moderators with their high efficiency have great potential but need to be developed. The vane arrangement is the most commonly found

  18. Origin and annihilation physics of positrons in the Galaxy

    International Nuclear Information System (INIS)

    Alexis, Anthony

    2014-01-01

    A gamma radiation at 511 keV is observed since the early 1970's toward the Galactic bulge region. This emission is the signature of a large number of electron-positron annihilations, the positron being the electron's antiparticle. Unfortunately, the origin of the positrons responsible for this emission is still a mystery. Many positron-source candidates have been suggested but none of them can account for the galactic annihilation emission. The spatial distribution of this emission is indeed very atypical. Since 2002, the SPI spectrometer onboard the INTEGRAL space laboratory revealed an emission strongly concentrated toward the galactic bulge and a weaker emission from the galactic disk. This morphology is unusual because it does not correspond to any of the known galactic astrophysical-object or interstellar-matter distributions. The assumption that positrons annihilate close to their sources (i.e. the spatial distribution of the annihilation emission reflects the spatial distribution of the sources) has consequently been called into question. Recent studies suggest that positrons could propagate far away from their sources before annihilating. This physical aspect could be the key point to solve the riddle of the galactic positron origin. This thesis is devoted to the modelling of the propagation and annihilation of positrons in the Galaxy, in order to compare simulated spatial models of the annihilation emission with recent measurements provided by SPI/INTEGRAL. This method allows to put constraints on the origin of galactic positrons. We therefore developed a propagation Monte-Carlo code of positrons within the Galaxy in which we implemented all the theoretical and observational knowledge about positron physics (sources, transport modes, energy losses, annihilation modes) and the interstellar medium of our Galaxy (interstellar gas distributions, galactic magnetic fields, structures of the gaseous phases). Due to uncertainties in several physical parameters

  19. Positron radiography of ignition-relevant ICF capsules

    Science.gov (United States)

    Williams, G. J.; Chen, Hui; Field, J. E.; Landen, O. L.; Strozzi, D. J.

    2017-12-01

    Laser-generated positrons are evaluated as a probe source to radiograph in-flight ignition-relevant inertial confinement fusion capsules. Current ultraintense laser facilities are capable of producing 2 × 1012 relativistic positrons in a narrow energy bandwidth and short time duration. Monte Carlo simulations suggest that the unique characteristics of such positrons allow for the reconstruction of both capsule shell radius and areal density between 0.002 and 2 g/cm2. The energy-downshifted positron spectrum and angular scattering of the source particles are sufficient to constrain the conditions of the capsule between preshot and stagnation. We evaluate the effects of magnetic fields near the capsule surface using analytic estimates where it is shown that this diagnostic can tolerate line integrated field strengths of 100 T mm.

  20. The Effects of Surface Reconstruction and Electron-Positron Correlation on the Annihilation Characteristics of Positrons Trapped at Semiconductor Surfaces

    International Nuclear Information System (INIS)

    Fazleev, N. G.; Jung, E.; Weiss, A. H.

    2009-01-01

    Experimental positron annihilation induced Auger electron spectroscopy (PAES) data from Ge(100) and Ge(111) surfaces display several strong Auger peaks corresponding to M 4,5 N 1 N 2,3 , M 2,3 M 4,5 M 4,5 , M 2,3 M 4,5 V, and M 1 M 4,5 M 4,5 Auger transitions. The integrated peak intensities of Auger transitions have been used to obtain experimental annihilation probabilities for the Ge 3d and 3p core electrons. The experimental data were analyzed by performing theoretical studies of the effects of surface reconstructions and electron-positron correlations on image potential induced surface states and annihilation characteristics of positrons trapped at the reconstructed Ge(100) and Ge(111) surfaces. Calculations of positron surface states and annihilation characteristics have been performed for Ge(100) surface with (2x1), (2x2), and (4x2) reconstructions, and for Ge(111) surface with c(2x8) reconstruction. Estimates of the positron binding energy and annihilation characteristics reveal their sensitivity to the specific atomic structure of the topmost layers of the semiconductor and to the approximations used to describe electron-positron correlations. The results of these theoretical studies are compared with the ones obtained for the reconstructed Si(100)-(2x1) and Si(111)-(7x7) surfaces.

  1. Brucella ovis PA mutants for outer membrane proteins Omp10, Omp19, SP41, and BepC are not altered in their virulence and outer membrane properties.

    Science.gov (United States)

    Sidhu-Muñoz, Rebeca S; Sancho, Pilar; Vizcaíno, Nieves

    2016-04-15

    Mutants in several genes have been obtained on the genetic background of virulent rough (lacking O-polysaccharide) Brucella ovis PA. The target genes encode outer membrane proteins previously associated with the virulence of smooth (bearing O-polysaccharide chains in the lipopolysaccharide) Brucella strains. Multiple attempts to delete omp16, coding for a homologue to peptidoglycan-associated lipoproteins, were unsuccessful, which suggests that Omp16 is probably essential for in vitro survival of B. ovis PA. Single deletion of omp10 or omp19-that encode two other outer membrane lipoproteins--was achieved, but the simultaneous removal of both genes failed, suggesting an essential complementary function between both proteins. Two other deletion mutants, defective in the Tol-C-homologue BepC or in the SP41 adhesin, were also obtained. Surprisingly when compared to previous results obtained with smooth Brucella, none of the B. ovis mutants showed attenuation in the virulence, either in the mouse model or in cellular models of professional and non-professional phagocytes. Additionally, and in contrast to the observations reported with smooth Brucella strains, several properties related to the outer membrane remained almost unaltered. These results evidence new distinctive traits between naturally rough B. ovis and smooth brucellae. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Positron emitter labeled enzyme inhibitors

    International Nuclear Information System (INIS)

    Fowler, J.S.; MacGregor, R.R.; Wolf, A.P.; Langstrom, B.

    1990-01-01

    This invention involves a new strategy for imagining and mapping enzyme activity in the living human and animal body using positron emitter-labeled suicide enzyme inactivators or inhibitors which become covalently bound to the enzyme as a result of enzymatic catalysis. Two such suicide inactivators for monoamine oxidase have been labeled with carbon-11 and used to map the enzyme subtypes in the living human and animal body using PET. By using positron emission tomography to image the distribution of radioactivity produced by the body penetrating radiation emitted by carbon-11, a map of functionally active monoamine oxidase activity is obtained. Clorgyline and L-deprenyl are suicide enzyme inhibitors and irreversibly inhibit monoamine oxidase. When these inhibitors are labeled with carbon-11 they provide selective probes for monoamine oxidase localization and reactivity in vivo using positron emission tomography

  3. Instrumentation for positron emission tomography

    International Nuclear Information System (INIS)

    Budinger, T.F.; Derenzo, S.E.; Huesman, R.H.

    1984-01-01

    Positron emission tomography with a spatial resolution of 2 mm full width at half maximum for quantitation in regions of interest 4 mm in diameter will become possible with the development of detectors that achieve ultrahigh resolution. Improved resolution will be possible using solid-state photodetectors for crystal identification or photomultiplier tubes with many small electron multipliers. Temporal resolution of 2 seconds and gating of cyclic events can be accomplished if statistical requirements are met. The major physical considerations in achieving high-resolution positron emission tomography are the degradation in resolution resulting from positron range, emission angle, parallax error, detector sampling density, the sensitivity of various detector materials and packing schemes, and the tradeoff between temporal resolution and statistical accuracy. The accuracy of data required for physiological models depends primarily on the fidelity of spatial sampling independent of statistical constraints

  4. Nanometer cavities studied by positron annihilation

    International Nuclear Information System (INIS)

    Mogensen, O.E.

    1992-01-01

    Positronium (Ps) is trapped in cavities in insulating solids, and the lifetime of ortho Ps is determined by the size of the cavity. The information on the properties of the cavities obtained by use of the standard slow positron beam and the 'normal' positron annihilation techniques is compared for several selected cases. (author)

  5. A new slow positron beam facility using a compact cyclotron

    International Nuclear Information System (INIS)

    Hirose, Masafumi

    1998-01-01

    In 1993, Sumitomo Heavy Industries became the first in the world to successfully produce a slow positron beam using a compact cyclotron. Slow positron beam production using an accelerator had mainly consisted of using an electron linear accelerator (LINAC). However, the newly developed system that uses a compact cyclotron enabled cost reduction, downsizing of equipment, production of a DC slow positron beam, a polarized slow positron beam, and other benefits. After that, a genuine slow positron beam facility was developed with the construction of compact cyclotron No.2, and beam production in the new facility has already been started. The features of this new slow positron beam facility are explained below. 1) It is the world's first compact slow positron beam facility using a compact cyclotron. 2) It is the only genuine slow positron beam facility in the world which incorporates the production and use of a slow positron beam in the design stage of the cyclotron. To use a slow positron beam for non-destructive detection of lattice defects in semiconductor material, it is necessary to convert the beam into ultra-short pulses of several hundreds of pico-seconds. Sumitomo Heavy Industries has devised a new short-pulsing method (i.e. an induction bunching method) that enables the conversion of a slow positron beam into short pulses with an optimum pulsing electric field change, and succeeded in converting a slow positron beam into short pulses using this method for the first time in the world. Non-destructive detection of lattice defects in semiconductor material using this equipment has already been started, and some information about the depth distribution, size, density, etc. of lattice defects has already been obtained. (J.P.N.)

  6. Plasma Wakefield Acceleration of an Intense Positron Beam

    Energy Technology Data Exchange (ETDEWEB)

    Blue, B

    2004-04-21

    The Plasma Wakefield Accelerator (PWFA) is an advanced accelerator concept which possess a high acceleration gradient and a long interaction length for accelerating both electrons and positrons. Although electron beam-plasma interactions have been extensively studied in connection with the PWFA, very little work has been done with respect to positron beam-plasma interactions. This dissertation addresses three issues relating to a positron beam driven plasma wakefield accelerator. These issues are (a) the suitability of employing a positron drive bunch to excite a wake; (b) the transverse stability of the drive bunch; and (c) the acceleration of positrons by the plasma wake that is driven by a positron bunch. These three issues are explored first through computer simulations and then through experiments. First, a theory is developed on the impulse response of plasma to a short drive beam which is valid for small perturbations to the plasma density. This is followed up with several particle-in-cell (PIC) simulations which study the experimental parameter (bunch length, charge, radius, and plasma density) range. Next, the experimental setup is described with an emphasis on the equipment used to measure the longitudinal energy variations of the positron beam. Then, the transverse dynamics of a positron beam in a plasma are described. Special attention is given to the way focusing, defocusing, and a tilted beam would appear to be energy variations as viewed on our diagnostics. Finally, the energy dynamics imparted on a 730 {micro}m long, 40 {micro}m radius, 28.5 GeV positron beam with 1.2 x 10{sup 10} particles in a 1.4 meter long 0-2 x 10{sup 14} e{sup -}/cm{sup 3} plasma is described. First the energy loss was measured as a function of plasma density and the measurements are compared to theory. Then, an energy gain of 79 {+-} 15 MeV is shown. This is the first demonstration of energy gain of a positron beam in a plasma and it is in good agreement with the predictions

  7. High efficiency cyclotron trap assisted positron moderator

    OpenAIRE

    Gerchow, L.; Cooke, D. A.; Braccini, S.; Döbeli, M.; Kirch, K.; Köster, U.; Müller, A.; Van Der Meulen, N. P.; Vermeulen, C.; Rubbia, A.; Crivelli, P.

    2017-01-01

    We report the realisation of a cyclotron trap assisted positron tungsten moderator for the conversion of positrons with a broad keV- few MeV energy spectrum to a mono-energetic eV beam with an efficiency of 1.8(2)% defined as the ratio of the slow positrons divided by the $\\beta^+$ activity of the radioactive source. This is an improvement of almost two orders of magnitude compared to the state of the art of tungsten moderators. The simulation validated with this measurement suggests that usi...

  8. Positron emission tomography. Positronemisionstomografi

    Energy Technology Data Exchange (ETDEWEB)

    Bolwig, T G; Haunsoe, S; Dahlgaard Hove, J; Hesse, B; Hoejgard, L; Jensen, M; Paulson, O B; Hastrup Svendsen, J; Soelvsten Soerensen, S

    1994-10-01

    Positron emission tomography (PET) is a method for quantitative imaging of regional physiological and biochemical parameters. Positron emitting radioactive isotopes can be produced by a cyclotron, eg. the biologically important carbon ([sup 11]C), oxygen ([sup 15]O), and nitrogen ([sup 13]N) elements. With the tomographic principles of the PET scanner the quantitative distribution of the administered isotopes can be determined and images can be provided as well as dynamic information on blood flow, metabolism and receptor function. In neurology PET has been used for investigations on numerous physiological processes in the brain: circulation, metabolism and receptor studies. In Parkinson's disease PET studies have been able to localize the pathology specifically, and in early stroke PET technique can outline focal areas with living but non-functioning cells, and this could make it possible to intervene in this early state. With positron emission tomography a quantitative evaluation of myocardial blood flow, glucose and fatty acid metabolism can be made as well as combined assessments of blood flow and metabolism. Combined studies of blood flow and metabolism can determine whether myocardial segments with abnormal motility consist of necrotic or viable tissue, thereby delineating effects of revascularisation. In the future it will probably be possible to characterize the myocardial receptor status in different cardiac diseases. The PET technique is used in oncology for clinical as well as more basic research on tumor perfusion and metabolism. Further, tumor uptake of positron labelled cytotoxic drugs might predict the clinical benefit of treatment. (au) (19 refs.).

  9. Study of radiation damage in metals by positron annihilation

    International Nuclear Information System (INIS)

    Gauster, W.B.

    1977-01-01

    Positron annihilation is a sensitive technique for probing defects in metals and it has recently been shown to be a valuable tool for the study of radiation damage. After an introduction to the three basic experimental methods (angular correlation, Doppler broadening, and lifetime measurements), the interaction of positrons with lattice defects is reviewed. Results for the annealing of damage after low temperature irradiation are used to show that positron annihilation has provided new information on annealing kinetics. The role of positron techniques in characterizing complex defect structures resulting from high-temperature neutron irradiation is reviewed and the possible utility of positron annihilation as a nondestructive monitor of property changes is pointed out

  10. Imaging optimizations with non-pure and high-energy positron emitters in small animal positron computed tomography

    International Nuclear Information System (INIS)

    Harzmann, Sophie

    2014-01-01

    The contribution on imaging optimizations with non-pure and high-energy positron emitters in small animal positron emission tomography (PET) covers the following topics: physical fundamentals of PET, mathematical image reconstruction and data analyses, Monte-Carlo simulations and implemented correction scheme, quantification of cascade gamma coincidences based on simulations and measurements, sinogram based corrections, restoration of the spatial resolution, implementation of full corrections.

  11. Application of position-sensitive detectors to positron imaging

    International Nuclear Information System (INIS)

    Yamashita, Takaji; Uchida, Hiroshi; Watanabe, Mitsuo; Omura, Tomohide

    1994-01-01

    Positron imaging including positron emission tomography (PET) is expected to be a promising tool for basic and clinical research, because it makes possible the study of regional chemistry within multiple organs of the body in living human beings and experimental animals. New schemes of high resolution block detectors have been developed to improve the performance of positron imaging systems, which employ small segments of bismuth germanate (BGO) arrays and position-sensitive photomultiplier tubes (PS-PMT). The coincidence detector resolution of less than 2.0 mm in full width at half maximum was achieved with the detectors, which is very close to the theoretical resolution limit in positron imaging. (author)

  12. The MEG positron spectrometer

    International Nuclear Information System (INIS)

    Nishiguchi, Hajime

    2007-01-01

    We have been developing an innovative spectrometer for the MEG experiment at the Paul Scherrer Institute (PSI) in Switzerland. This experiment searches for a lepton flavour violating decay μ + →e + γ with a sensitivity of 10 -13 in order to explore the region predicted by supersymmetric extensions of the standard model. The MEG positron spectrometer consists of a specially designed superconducting solenoidal magnet with a highly graded field, an ultimate low-mass drift chamber system, and a precise time measuring counter system. This innovative positron spectrometer is described here focusing on the drift chamber system

  13. Depth profiling of boron implanted silicon by positron beam

    International Nuclear Information System (INIS)

    Oevuenc, S.

    2004-01-01

    Positron depth profiling analyses of low energy implants of silicon aim to observe tbe structure and density of the vacancies generating by implantation and the effect of annealing. This work present the results to several set of data starting S and W parameters. Boron implanted Silicon samples with different implantation energies,20,22,24,and 26 keV are analyzed by Slow positron beam (0-40 keV and 10 5 e + /s )(Variable Energy Positron) at the Positron Centre Delf-HOLLAND

  14. Characterization of lacunar defects by positrons annihilation

    CERN Document Server

    Barthe, M F; Blondiaux, G

    2003-01-01

    Among the nondestructive methods for the study of matter, the positrons annihilation method allows to sound the electronic structure of materials by measuring the annihilation characteristics. These characteristics depend on the electronic density as seen by the positon, and on the electron momentums distribution which annihilate with the positon. The positon is sensible to the coulombian potential variations inside a material and sounds preferentially the regions away from nuclei which represent potential wells. The lacunar-type defects (lack of nuclei) represent deep potential wells which can trap the positon up to temperatures close to the melting. This article describes the principles of this method and its application to the characterization of lacunar defects: 1 - positrons: matter probes (annihilation of electron-positon pairs, annihilation characteristics, positrons sources); 2 - positrons interactions in solids (implantation profiles, annihilation states, diffusion and trapping, positon lifetime spec...

  15. Positron annihilation spectroscopic studies of 6H silicon carbide

    International Nuclear Information System (INIS)

    Hu, Y.F.; Lam, C.H.; Ling, C.C.; Fung, S.; Beling, C.D.; Weng, H.M.

    2001-01-01

    Positron lifetime measurements have been performed on p-type and n-type 6H-SiC with temperatures varying from 10 K to 290 K. The V C V Si divacancy is observed in both types of 6H-SiC where the V Si related defect is only found in the n-type material. Positron trapping into a defect with lifetime value close to the bulk was found to compete with positron trapping into V Si or V C V Si at temperatures lower than 80 K. The positron diffusion length of the 1400 C annealed n-type 6H-SiC has also been measured at different temperatures with the use of a positron beam. Positron diffusion was found to be limited by acoustic phonon scattering at T=150-300 K. However, at T=50-150 K, D + follows T 2.12±0.02 and the details of the physical process is not yet known. (orig.)

  16. The effects of low-energy scattering on positron implantation

    Energy Technology Data Exchange (ETDEWEB)

    Ritley, K.A. (Dept. of Physics and Materials Research Laboratory, Univ. of Illinois, Urbana, IL (United States)); Lynn, K.G.; Ghosh, V.; Welch, D.O. (Brookhaven National Lab., Upton, NY (United States))

    1992-01-01

    Existing Monte Carlo models are capable of simulating the behavior of positrons incident at keV energies, then following the energy loss process to arbitrary final kinetic energies of from 20 eV to 100 eV. This work describes a Monte Carlo simulation of the final stages of positron thermalization in Al, from 25 eV to thermal energies, via the mechanisms of conduction-electron and longitudinal acoustic phonon scattering. The latter stages of thermalization can have important effects on the stopping profiles and mean depth. A novel way to obtain information about positron energy loss by considering the time-evolution of a point-concentration (delta-function distribution) of positrons is described. The effects of a positive positron work function are examined for the first time in the context of a positron Monte Carlo calculation. Finally, some issues relating to the agreement of Monte Carlo calculations with experimental data are discussed. 6 figs., 16 refs.

  17. The effects of low-energy scattering on positron implantation

    Energy Technology Data Exchange (ETDEWEB)

    Ritley, K.A. [Dept. of Physics and Materials Research Laboratory, Univ. of Illinois, Urbana, IL (United States); Lynn, K.G.; Ghosh, V.; Welch, D.O. [Brookhaven National Lab., Upton, NY (United States)

    1992-12-31

    Existing Monte Carlo models are capable of simulating the behavior of positrons incident at keV energies, then following the energy loss process to arbitrary final kinetic energies of from 20 eV to 100 eV. This work describes a Monte Carlo simulation of the final stages of positron thermalization in Al, from 25 eV to thermal energies, via the mechanisms of conduction-electron and longitudinal acoustic phonon scattering. The latter stages of thermalization can have important effects on the stopping profiles and mean depth. A novel way to obtain information about positron energy loss by considering the time-evolution of a point-concentration (delta-function distribution) of positrons is described. The effects of a positive positron work function are examined for the first time in the context of a positron Monte Carlo calculation. Finally, some issues relating to the agreement of Monte Carlo calculations with experimental data are discussed. 6 figs., 16 refs.

  18. Temperature dependence of positron trapping by vacancies, loops and voids in molybdenum

    International Nuclear Information System (INIS)

    Bentzon, M.D.; Linderoth, S.; Petersen, K.

    1985-01-01

    The temperature dependence of positron trapping by defects in molybdenum has been studied. By resolving positron lifetime spectra into three components, it has been possible to distinguish the temperature dependence of positron trapping into loops and voids. The results show that the positron trapping rate into voids depends linearly on temperature. The temperature dependence of positron trapping by loops can be interpreted as positrons being trapped by jogs, directly or via the dislocation line. The temperature dependence of positrons trapped by loops is argued mainly to be due to the trapping at the dislocation line, and not to detrapping. The observed temperature dependence of positron annihilation parameters in an electron irradiated sample (below stage III), is explained by competitive positron trapping in interstitial loops at low temperatures

  19. Temperature dependence of the fraction of re-emitted positrons, the positron work function, and the positronium fraction for Cu(III)+S

    International Nuclear Information System (INIS)

    Schultz, P.J.; Lynn, K.G.

    1982-01-01

    A beam of 1 keV positrons incident on a Cu(111)+S surface has been used to study the dependence on temperature of the positron work function (phi/sub +/), the yield of re-emitted positrons (Y) and of the positronium (Ps) fraction. A positive dependence of the slow-positron yield on temperature is found which is attributed in part to a reduction in the magnitude of phi/sub +/ (approx. 25%) at 50 K relative to its value at 300 K. A similar, though weaker, positive dependence on temperature was seen for the Ps fraction down to 40 K. We present a suggestion for the apparent lack of reflection

  20. Positron-trapping mechanism at dislocations in Zn

    DEFF Research Database (Denmark)

    Hidalgo, Carlos; Linderoth, Søren; Diego, Nieves de

    1987-01-01

    the average lifetime and the intensity of the long component decrease with increasing temperature. The experimental results are very well described in terms of a generalized trapping model where it is assumed that positrons become trapped in deep traps (jogs) via shallow traps (dislocation lines......). The temperature dependence of the positron-lifetime spectra below 120 K is attributed to the temperature dependence of the trapping rate to the dislocation line. The experimental results have demonstrated that detrapping processes from the dislocation line take place above 120 K. The positron binding energy...

  1. In-situ positron emission of CO oxidation

    OpenAIRE

    Vonkeman, K.A.; Jonkers, G.; Wal, van der, S.W.A.; Santen, van, R.A.

    1993-01-01

    Using a Neuro ECAT positron tomog., the Positron Emission computed Tomog. (PET) was utilized to image the catalytic oxidn. of CO by using CO and CO2, labeled with short lived positron emitting nuclides. Studies were performed over highly dispersed CeO2/g-Al2O3 supported Pt and Rh catalysts. With a math. model of the reaction kinetics, based on the elementary steps of the catalytic reaction and partially on literature surface science data, the effect of CeO2 promotion and the presence of NO we...

  2. Positron emission tomography studies of brain receptors

    International Nuclear Information System (INIS)

    Maziere, B.; Maziere, M.

    1991-01-01

    Probing the regional distribution and affinity of receptors in the brain, in vivo, in human and non human primates has become possible with the use of selective ligands labelled with positron emitting radionuclides and positron emission tomography (PET). After describing the techniques used in positron emission tomography to characterize a ligand receptor binding and discussing the choice of the label and the limitations and complexities of the in vivo approach, the results obtained in the PET studies of various neurotransmission systems: dopaminergic, opiate, benzodiazepine, serotonin and cholinergic systems are reviewed

  3. Positron-emitting raionuclides: present and future status

    International Nuclear Information System (INIS)

    Lambrecht, R.M.

    1979-01-01

    A tabulation of 157 positron-emitting radionuclides that have the physical characteristics deemed appropriate for radiopharmaceutical use in conjunction with positron emission tomography is provided. The most promising radionuclides are within the production capabilities of a variable-energy cyclotron accelerating protons to about 40 MeV and deuterons, helium-3, and helium-4 to compatable energies. To data only 27 positron-emitting radionuclides have been subjected to radiopharmaceutical consideration, whereas only 11 C, 13 N, 15 O, 18 F, 38 K, and 68 Ga have proved to be especially promising. 2 tables

  4. Positron reemission microscopy

    International Nuclear Information System (INIS)

    Brandes, G.F.; Canter, K.F.; Mills, A.P. Jr.

    1991-01-01

    The positron reemission microscope (PRM), originally proposed by Hulett, Dale and Pendyala, operates on principles fundamentally different from those utilized in existing microscopes and offers sensitivity and contrast not available in conventional microscopes

  5. Probing Positron Gravitation at HERA

    International Nuclear Information System (INIS)

    Gharibyan, Vahagn

    2015-07-01

    An equality of particle and antiparticle gravitational interactions holds in general relativity and is supported by indirect observations. Here I develop a method based on high energy Compton scattering to measure the gravitational interaction of accelerated charged particles. Within that formalism the Compton spectra measured at HERA rule out the positron's anti-gravity and hint for a positron's 1.3(0.2)% weaker coupling to the gravitational field relative to an electron.

  6. Probing Positron Gravitation at HERA

    Energy Technology Data Exchange (ETDEWEB)

    Gharibyan, Vahagn

    2015-07-15

    An equality of particle and antiparticle gravitational interactions holds in general relativity and is supported by indirect observations. Here I develop a method based on high energy Compton scattering to measure the gravitational interaction of accelerated charged particles. Within that formalism the Compton spectra measured at HERA rule out the positron's anti-gravity and hint for a positron's 1.3(0.2)% weaker coupling to the gravitational field relative to an electron.

  7. Multi-pair states in electron–positron pair creation

    Directory of Open Access Journals (Sweden)

    Anton Wöllert

    2016-09-01

    Full Text Available Ultra strong electromagnetic fields can lead to spontaneous creation of single or multiple electron–positron pairs. A quantum field theoretical treatment of the pair creation process combined with numerical methods provides a description of the fermionic quantum field state, from which all observables of the multiple electron–positron pairs can be inferred. This allows to study the complex multi-particle dynamics of electron–positron pair creation in-depth, including multi-pair statistics as well as momentum distributions and spin. To illustrate the potential benefit of this approach, it is applied to the intermediate regime of pair creation between nonperturbative Schwinger pair creation and perturbative multiphoton pair creation where the creation of multi-pair states becomes nonnegligible but cascades do not yet set in. Furthermore, it is demonstrated how spin and helicity of the created electrons and positrons are affected by the polarization of the counterpropagating laser fields, which induce the creation of electron–positron pairs.

  8. Multi-pair states in electron–positron pair creation

    Energy Technology Data Exchange (ETDEWEB)

    Wöllert, Anton, E-mail: woellert@mpi-hd.mpg.de; Bauke, Heiko, E-mail: heiko.bauke@mpi-hd.mpg.de; Keitel, Christoph H.

    2016-09-10

    Ultra strong electromagnetic fields can lead to spontaneous creation of single or multiple electron–positron pairs. A quantum field theoretical treatment of the pair creation process combined with numerical methods provides a description of the fermionic quantum field state, from which all observables of the multiple electron–positron pairs can be inferred. This allows to study the complex multi-particle dynamics of electron–positron pair creation in-depth, including multi-pair statistics as well as momentum distributions and spin. To illustrate the potential benefit of this approach, it is applied to the intermediate regime of pair creation between nonperturbative Schwinger pair creation and perturbative multiphoton pair creation where the creation of multi-pair states becomes nonnegligible but cascades do not yet set in. Furthermore, it is demonstrated how spin and helicity of the created electrons and positrons are affected by the polarization of the counterpropagating laser fields, which induce the creation of electron–positron pairs.

  9. Multi-pair states in electron–positron pair creation

    International Nuclear Information System (INIS)

    Wöllert, Anton; Bauke, Heiko; Keitel, Christoph H.

    2016-01-01

    Ultra strong electromagnetic fields can lead to spontaneous creation of single or multiple electron–positron pairs. A quantum field theoretical treatment of the pair creation process combined with numerical methods provides a description of the fermionic quantum field state, from which all observables of the multiple electron–positron pairs can be inferred. This allows to study the complex multi-particle dynamics of electron–positron pair creation in-depth, including multi-pair statistics as well as momentum distributions and spin. To illustrate the potential benefit of this approach, it is applied to the intermediate regime of pair creation between nonperturbative Schwinger pair creation and perturbative multiphoton pair creation where the creation of multi-pair states becomes nonnegligible but cascades do not yet set in. Furthermore, it is demonstrated how spin and helicity of the created electrons and positrons are affected by the polarization of the counterpropagating laser fields, which induce the creation of electron–positron pairs.

  10. Organic synthesis with short-lived positron-emitting radioisotopes

    International Nuclear Information System (INIS)

    Pike, V.W.

    1988-01-01

    Chemistry with short-lived positron-emitting radioisotopes of the non-metals, principally 11 C, 13 N and 18 F, has burgeoned over the last decade. This has been almost entirely because of the emergence of positron emission tomography (PET) as a powerful non-invasive technique for investigating pathophysiology in living man. PET is essentially an external technique for the rapid serial reconstruction of the spatial distribution of any positron-emitting radioisotope that has been administered in vivo. Such a distribution is primarily governed by the chemical form in which the positron-emitting radioisotope is incorporated, and importantly for clinical research, is often perturbed by physical, biological or clinical factors. Judicious choice of the chemical form enables specific biological information to be obtained. For example, the labelling of glucose with a positron-emitting radioisotope could be expected to provide a radiopharmaceutical for the study of glucose utilisation in both health and disease. (author)

  11. Positron trapping at defects in copper oxide superconductors

    International Nuclear Information System (INIS)

    McMullen, T.; Jena, P.; Khanna, S.N.; Li, Y.; Jensen, K.O.

    1991-01-01

    Positron states and lifetimes at defects in the copper oxide superconductors La 2-x Sr x CuO 4 , YBa 2 Cu 3 O 7-x , and Bi 2 Sr 2 CaCu 2 O 8+x are calculated with use of the superposed-atom model. In the Bi 2 Sr 2 CaCu 2 O 8+x compound, we find that the smaller metal-ion vacancies appear to only bind positrons weakly, while missing oxygens do not trap positrons. In contrast, metal-ion vacancies in La 2-x Sr x CuO 4 and YBa 2 Cu 3 O 7-x bind positrons by ∼1 eV, and oxygen-related defects appear to be the weak-binding sites in these materials. The sites that bind positrons only weakly, by energies ∼k BT , are of particular interest in view of the complex temperature dependences of the annihilation characteristics that are observed in these materials

  12. Positrons trapped in polyethylene: Electric field effect

    International Nuclear Information System (INIS)

    Bertolaccini, M.; Bisi, A.; Gambarini, G.; Zappa, L.

    1978-01-01

    The intensity of the iot 2 -component of positrons annihilated in polyethylene is found to increase with increasing electric field, while the formation probability of the positron state responsible for this component remains independent of the field. (orig.) 891 HPOE [de

  13. ANTICOOL: Simulating positron cooling and annihilation in atomic gases

    Science.gov (United States)

    Green, D. G.

    2018-03-01

    The Fortran program ANTICOOL, developed to simulate positron cooling and annihilation in atomic gases for positron energies below the positronium-formation threshold, is presented. Given positron-atom elastic scattering phase shifts, normalised annihilation rates Zeff, and γ spectra as a function of momentum k, ANTICOOL enables the calculation of the positron momentum distribution f(k , t) as a function of time t, the time-varying normalised annihilation rate Z¯eff(t) , the lifetime spectrum and time-varying annihilation γ spectra. The capability and functionality of the program is demonstrated via a tutorial-style example for positron cooling and annihilation in room temperature helium gas, using accurate scattering and annihilation cross sections and γ spectra calculated using many-body theory as input.

  14. Irradiation damage of alkali halide crystals during positron bombardment

    International Nuclear Information System (INIS)

    Arefiev, K.P.; Arefiev, V.P.; Vorobiev, S.A.

    1978-01-01

    The bleaching effect of positron irradiation of KCl and KBr single crystals previously coloured with electrons or protons was investigated. Positrons injection in the coloured alkali halide samples reduced the F-centres concentration considerably. For KCl crystals thicker than the positrons range the appearance of additional bands in the absorption spectra is noticeable. The experimental data show that the bleaching phenomenon should be observed merely throughout the positron exposure both for irradiated and non-irradiated regions of the sample. Irradiation effects, due to positron source, on the peak counting rate of (γ-γ) angular correlation in KCl crystals under applied magnetic field were also investigated. The growth of peak counting rate shows the increase of positronium-like states formation near defects of cation sublattice. (author)

  15. A question of balance: Kinetic balance for electrons and positrons

    International Nuclear Information System (INIS)

    Dyall, Kenneth G.

    2012-01-01

    Graphical abstract: Kinetic balance for both electrons and positrons is achieved by applying the correct relation for positive and negative energy states separately and then using the electron and positron eigensolutions from the separate diagonalizations of the Hamiltonian as a dual basis. Highlights: ► Kinetic balance for electrons and positrons is achieved in a dual atomic basis. ► Dual atomic balance alleviates, but does not eliminate, energy prolapse. ► Positron affinities converge quicker with basis set size with dual atomic balance. - Abstract: The kinetic balance criterion used in current relativistic basis set codes is satisfied by the electron solutions of the Dirac equation, but not the positron solutions. A proposal for applying kinetic balance to both sets of solutions is presented. The method is applied along with “normal” kinetic balance to one-electron systems, to investigate its possible relation to prolapse, and to the positron affinity of F − , to investigate the kinetic energy deficiency for positron solutions. The new method reduces but does not eliminate prolapse for energy-optimized basis sets, and provides faster and smoother convergence with basis set size for the positron affinity.

  16. Positron production in heavy-ion collisions. II. Application of the formalism to the case of the U+U collision

    International Nuclear Information System (INIS)

    Tomoda, T.

    1982-01-01

    The method developed in the preceding paper is applied to the calculation of the spectra of positrons produced in the U + U collision. Matrix elements of the radial derivative operator between adiabatic basis states are calculated in the monopole approximation, with the finite nuclear size taken into account. These matrix elements are then modified for the supercritical case with the use of the analytical method presented in paper I of this series. The coupled differential equations for the occupation amplitudes of the basis states are solved and the positron spectra are obtained for the U + U collision. It is shown that the decomposition of the production probability into a spontaneous and an induced part depends on the definition of the resonance state and cannot be given unambiguously. The results are compared with those obtained by Reinhardt et al

  17. Vacancy-type defects induced by grinding of Si wafers studied by monoenergetic positron beams

    Energy Technology Data Exchange (ETDEWEB)

    Uedono, Akira; Yoshihara, Nakaaki [Division of Applied Physics, Faculty of Pure and Applied Science, University of Tsukuba, Tsukuba, Ibaraki 305-8573 (Japan); Mizushima, Yoriko [Devices and Materials Labs Fujitsu Laboratories Ltd., Atsugi, Kanagawa 243-0197 (Japan); ICE Cube Center, Tokyo Institute of Technology, Yokohama 226-8503 (Japan); Kim, Youngsuk [ICE Cube Center, Tokyo Institute of Technology, Yokohama 226-8503 (Japan); Disco Corporation, Ota, Tokyo 143-8580 (Japan); Nakamura, Tomoji [Devices and Materials Labs Fujitsu Laboratories Ltd., Atsugi, Kanagawa 243-0197 (Japan); Ohba, Takayuki [ICE Cube Center, Tokyo Institute of Technology, Yokohama 226-8503 (Japan); Oshima, Nagayasu; Suzuki, Ryoichi [Research Institute of Instrumentation Frontier, National Institute of Advanced Industrial Science and Technology, Tsukuba, Ibaraki 305-8568 (Japan)

    2014-10-07

    Vacancy-type defects introduced by the grinding of Czochralski-grown Si wafers were studied using monoenergetic positron beams. Measurements of Doppler broadening spectra of the annihilation radiation and the lifetime spectra of positrons showed that vacancy-type defects were introduced in the surface region (<98 nm), and the major defect species were identified as (i) relatively small vacancies incorporated in dislocations and (ii) large vacancy clusters. Annealing experiments showed that the defect concentration decreased with increasing annealing temperature in the range between 100 and 500°C. After 600–700°C annealing, the defect-rich region expanded up to about 170 nm, which was attributed to rearrangements of dislocation networks, and a resultant emission of point defects toward the inside of the sample. Above 800°C, the stability limit of those vacancies was reached and they started to disappear. After the vacancies were annealed out (900°C), oxygen-related defects were the major point defects and they were located at <25 nm.

  18. Digital positron lifetime spectroscopy: present status and outlook

    International Nuclear Information System (INIS)

    Becvar, F.

    2007-01-01

    This contribution summarizes achievements in instrumentation for positron lifetime measurements with emphasis on digital spectrometric systems. A significant part of the data presented are based on a long-term exploitation of a conventional positron lifetime spectrometer developed at Charles University in early 90s, on bench-mark testing measurements with this spectrometer working temporarily in conjunction with a pair of 8-bit, 4 GS/s digitizers and on analogous measurements with a recently assembled digital positron lifetime spectrometer. In addition, results from testing experiments with microchannel plate photomultipliers are briefly reported. Further development of positron lifetime technique is discussed. (copyright 2007 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  19. Quality control procedures in positron tomography

    International Nuclear Information System (INIS)

    Spinks, T.; Jones, T.; Heather, J.; Gilardi, M.

    1989-01-01

    The derivation of physiological parameters in positron tomography relies on accurate calibration of the tomograph. Normally, the calibration relates image pixel count density to the count rate from an external blood counter per unit activity concentration in each device. The quality control of the latter is simple and relies on detector stability assessed by measurement of a standard source of similar geometry to a blood sample. The quality control of the tomographic data depends on (i) detector stability, (ii) uniformity of calibration and normalisation sources and (iii) reproducibility of the attenuation correction procedure. A quality control procedure has been developed for an 8 detector ring (15 transaxial plane) tomograph in which detector response is assessed by acquiring data from retractable transmission ring sources. These are scanned daily and a print out of detector efficiencies is produced as well as changes from a given data. This provides the raw data from which decisions on recalibration or renormalisation are made. (orig.)

  20. TOP counter for particle identification at the Belle II experiment

    Energy Technology Data Exchange (ETDEWEB)

    Inami, Kenji

    2014-12-01

    Ring imaging Cherenkov counter, named TOP counter, utilizing precise photon detection timing has been developed as a particle identification detector for the Belle II experiment. The real size prototype has been produced and tested with 2 GeV positrons at Spring-8 LEPS beam line. The quartz radiator production and assembling with microchannel plate photomultipliers was successfully carried out. The beam test data shows good agreement with full Monte-Carlo simulation results in the ring image and the distribution of number of detected photons and timing information. - Highlights: • TOP counter was developed as a particle identification detector for the Belle II experiment. • The real size prototype was produced and tested with 2 GeV positrons. • The quartz radiator production and assembling with MCP-PMT was successfully carried out. • The beam test data shows good agreement with full Monte-Carlo simulation results.

  1. Positron annihilation studies on BeO powders

    International Nuclear Information System (INIS)

    Brauer, G.; Kerbe, F.; Kajcsos, Z.; Ashry, A.

    1984-01-01

    The sintering behaviour of two differently produced BeO powders is studied by positron annihilation. The positron lifetime in dislocations is found to be tau/sub d/ = (185 +- 2) ps, whereas for the perfect lattice tau/sub c/ = (130 +- 2) ps. (author)

  2. CO2 absorption of perovskites as seen by positron lifetime spectroscopy

    International Nuclear Information System (INIS)

    Suevegh, K.; Nomura, K.; Juhasz, G.; Homonnay, Z.; Vertes, A.

    2000-01-01

    The CO 2 absorption of several ABO 3 type perovskites was studied by positron lifetime spectroscopy. The longer positron lifetime was associated with positrons trapped by A site vacancies. The evaluated positron lifetime data indicated the relative stability of the crystal structure of Sr(Co 0.5 Fe 0.5 )O 3-δ against Ca doping at low Ca concentrations. Oxygen desorption and CO 2 absorption/desorption could also be followed by positron lifetime spectroscopy. It was shown that the concentration of oxygen vacancies has a large effect on positron lifetime data through the electron density of A site vacancies.

  3. Positron annihilation study in La2CuO4

    International Nuclear Information System (INIS)

    Kubo, Y.; Asano, S.

    1992-01-01

    The positron annihilation study for La 2 CuO 4 are performed using the full-potential linearized augmented-plane-wave(FLAPW) calculated electron and positron densities. The electron-positron momentum density(EPMD) is computed, and the well known Lock-Crisp-West(LCW) zone folding of the EPMD is produced. In the LCW analysis, small residual variations of order about 3 % are observed. The calculations show that the relative weights of the Fermi surface discontinuities are substantially altered due to the positron preferentially sampling the Cu-O plane region

  4. Secondary Electron Yield Measurements and Groove Chambers Tests in the PEP-II Beam Line Straights Sections

    International Nuclear Information System (INIS)

    Pivi, M

    2008-01-01

    Beam instability caused by the electron cloud has been observed in positron and proton storage rings and it is expected to be a limiting factor in the performance of the positron Damping Ring (DR) of future Linear Colliders such as ILC and CLIC [1, 2]. In the Positron Low Energy Ring (LER) of the PEP-II accelerator, we have installed vacuum chambers with rectangular grooves in a straight magnetic-free section to test this promising possible electron cloud mitigation technique. We have also installed a special chamber to monitor the secondary electron yield of TiN and TiZrV (NEG) coating, Copper, Stainless Steel and Aluminum under the effect of electron and photon conditioning in situ in the beam line. In this paper, we describe the ongoing R and D effort to mitigate the electron cloud effect for the ILC damping ring, the latest results on in situ secondary electron yield conditioning and recent update on the groove tests in PEP-II

  5. Positron kinetics in an idealized PET environment

    Science.gov (United States)

    Robson, R. E.; Brunger, M. J.; Buckman, S. J.; Garcia, G.; Petrović, Z. Lj.; White, R. D.

    2015-08-01

    The kinetic theory of non-relativistic positrons in an idealized positron emission tomography PET environment is developed by solving the Boltzmann equation, allowing for coherent and incoherent elastic, inelastic, ionizing and annihilating collisions through positronium formation. An analytic expression is obtained for the positronium formation rate, as a function of distance from a spherical source, in terms of the solutions of the general kinetic eigenvalue problem. Numerical estimates of the positron range - a fundamental limitation on the accuracy of PET, are given for positrons in a model of liquid water, a surrogate for human tissue. Comparisons are made with the ‘gas-phase’ assumption used in current models in which coherent scattering is suppressed. Our results show that this assumption leads to an error of the order of a factor of approximately 2, emphasizing the need to accurately account for the structure of the medium in PET simulations.

  6. Monte Carlo simulation of positron induced secondary electrons in thin carbon foils

    International Nuclear Information System (INIS)

    Cai, L H; Yang, B; Ling, C C; Beling, C D; Fung, S

    2011-01-01

    Emission of secondary electrons induced by the passage of low energy positrons through thin carbon foils was studied by the Monte Carlo method. The positron and electron elastic cross sections were calculated by partial wave analysis. The inelastic positron-valence-electron was described by the energy loss function obtained from dielectric theory. The positron-core-electron interaction was modelled by the Gryzinski's excitation function. Positron transport inside the carbon foil was simulated in detail. Secondary electrons created by positrons and high energy secondary electrons through inelastic interactions were tracked through the foil. The positron transmission coefficient and secondary electron yielded in forward and backward geometry are calculated and dependences on positron energy and carbon foil thickness are discussed.

  7. Positron energy distributions from a hybrid positron source based on channeling radiation

    International Nuclear Information System (INIS)

    Azadegan, B.; Mahdipour, A.; Dabagov, S.B.; Wagner, W.

    2013-01-01

    A hybrid positron source which is based on the generation of channeling radiation by relativistic electrons channeled along different crystallographic planes and axes of a tungsten single crystal and subsequent conversion of radiation into e + e − -pairs in an amorphous tungsten target is described. The photon spectra of channeling radiation are calculated using the Doyle–Turner approximation for the continuum potentials and classical equations of motion for channeled particles to obtain their trajectories, velocities and accelerations. The spectral-angular distributions of channeling radiation are found applying classical electrodynamics. Finally, the conversion of radiation into e + e − -pairs and the energy distributions of positrons are simulated using the GEANT4 package

  8. Positron collisions with helium and alkaline earth-like atoms

    International Nuclear Information System (INIS)

    Campbell, C.P.

    1998-09-01

    This doctoral thesis is subdivided into: 1. Theory of positron collisions with helium and alkaline earth-like atoms, 2. Positron collisions with helium, magnesium, calcium, zinc, 3. Intercomparison of positron scattering by all those elements. The appendix of this work gives details of the numerical calculations and expands on the wavefunctions used

  9. Design studies for the Positron Factory

    International Nuclear Information System (INIS)

    Okada, S.; Sunaga, H.; Kaneko, H.; Masuno, S.; Kawasuso, A.; Sakai, T.; Takizawa, H.; Yotsumoto, K.; Honda, Y.; Tagawa, S.

    1996-01-01

    In the design study for the Positron Factory, a feasibility of simultaneous extraction of multi-channel monoenergetic positron beams, which had been proposed at the previous conference (Linac 94), was demonstrated by an experiment using an electron linac. On the basis of the experimental result, an efficient moderator structure, which is composed of honeycomb-like assembled moderator foils and reflectors, is proposed. (author)

  10. Positron emission tomography of the heart

    International Nuclear Information System (INIS)

    Budinger, T.F.; Yano, Y.; Mathis, C.A.; Moyer, B.R.; Huesman, R.H.; Derenzo, S.E.

    1983-01-01

    Positron emission tomography (PET) offers the opportunity to noninvasively measure heart muscle blood perfusion, oxygen utilization, metabolism of fatty acids, sugars and amino acids. This paper reviews physiological principles which are basic to PET instrumentation for imaging the heart and gives examples of the application of positron emission tomography for measuring myocardial flow and metabolism. 33 references, 11 figures, 1 table

  11. Hydrogen interaction with oxidized Si(111) probed with positrons

    International Nuclear Information System (INIS)

    Lynn, K.G.; Nielsen, B.; Welch, D.O.

    1989-01-01

    A variable-energy positron beam was utilized to study the interface action of hydrogen with Si(111) covered by an ultrahigh-vacuum thermally grown oxide of 2-3 nm thickness. It was observed that positrons implanted at shallow depth (< 100 nm) after diffusion are trapped either at the interface between the oxide and the Si or in the oxide. The positron-annihilation characteristics of these trapped positrons are found to be very sensitive to hydrogen exposure. The momentum distribution of the annihilating positron-electron pair, as observed in the Doppler broadening of the annihilation line, broadens considerably after exposure to hydrogen. The effect recovers after annealing at ≅ 1100 K, suggesting a hydrogen binding at the interface of ∼ 3 ± 0.3 eV. (author). 18 refs., 3 figs

  12. LEP - Large Electron Positron Exhibition LEPFest 2000

    CERN Multimedia

    2000-01-01

    The Large Electron-Positron Collider (LEP) is 27 km long. Its four detectors (ALEPH, DELPHI, L3, OPAL) measure precisely what happens in the collisions of electrons and positrons. These conditions only exist-ed in the Universe when it was about 10 -10 sec old.

  13. Applications and advances of positron beam spectroscopy: appendix a

    Energy Technology Data Exchange (ETDEWEB)

    Howell, R. H., LLNL

    1997-11-05

    Over 50 scientists from DOE-DP, DOE-ER, the national laboratories, academia and industry attended a workshop held on November 5-7, 1997 at Lawrence Livermore National Laboratory jointly sponsored by the DOE-Division of Materials Science, The Materials Research Institute at LLNL and the University of California Presidents Office. Workshop participants were charged to address two questions: Is there a need for a national center for materials analysis using positron techniques and can the capabilities at Lawrence Livermore National Laboratory serve this need. To demonstrate the need for a national center the workshop participants discussed the technical advantages enabled by high positron currents and advanced measurement techniques, the role that these techniques will play in materials analysis and the demand for the data. There were general discussions lead by review talks on positron analysis techniques, and their applications to problems in semiconductors, polymers and composites, metals and engineering materials, surface analysis and advanced techniques. These were followed by focus sessions on positron analysis opportunities in these same areas. Livermore now leads the world in materials analysis capabilities by positrons due to developments in response to demands of science based stockpile stewardship. There was a detailed discussion of the LLNL capabilities and a tour of the facilities. The Livermore facilities now include the worlds highest current beam of keV positrons, a scanning pulsed positron microprobe under development capable of three dimensional maps of defect size and concentration, an MeV positron beam for defect analysis of large samples, and electron momentum spectroscopy by positrons. This document is a supplement to the written summary report. It contains a complete schedule, list of attendees and the vuegraphs for the presentations in the review and focus sessions.

  14. Analysis of experimental positron-molecule binding energies

    International Nuclear Information System (INIS)

    Danielson, J R; Surko, C M; Young, J A

    2010-01-01

    Experiments show that positron annihilation on molecules frequently occurs via capture into vibrational Feshbach resonances. In these cases, the downshifts in the annihilation spectra from the vibrational mode spectra provide measures of the positron-molecule binding energies. An analysis of these binding energy data is presented in terms of the molecular dipole polarizability, the permanent dipole moment, and the number of π bonds in aromatic molecules. The results of this analysis are in reasonably good agreement with other information about positron-molecule bound states. Predictions for other targets and promising candidate molecules for further investigation are discussed.

  15. Positron production in heavy ion-atom collisions

    International Nuclear Information System (INIS)

    Kienle, P.

    1985-08-01

    Following an introduction into the concept of an atom with an overcritical field, established by a nucleus with a charge larger than 173, the spontaneous positron emission from such an atom with an 1s binding energy exceeding 2mc 2 is presented. Such a process, in which an electron is bound and a monoenergetic positron emitted turns the neutral into a charged vacuum. In a U-U di-nuclear system (Z=184) the spontaneous positron emission proceeds with an energy of about 300 keV corresponding to a decay time of 3x10 -19 sec. (orig./WL)

  16. Millimeter positron focusing using a hybrid lens design

    International Nuclear Information System (INIS)

    Cheung, C.K.; Kwan, P.Y.; Shan, Y.Y.; Naik, P.S.; Weng, H.M.; Beling, C.D.; Fung, S.

    2004-01-01

    The study of metal-semiconductor and metal-oxide-semiconductor systems with low energy positrons is made considerably easier if structures of millimeter dimension can be studied. For this reason the production of a positron beam of sub-millimeter dimension has been a long-term goal of the positron research group at the university of Hong Kong. The hybrid lens system employed consists of a standard Soa extraction lens in a magnetic field free region followed by a gridded Einzel lens that focuses positrons into a 100G magnetic funnel at an energy of 10keV for transportation to the target. Here we report on the present progress, by showing the capability of obtaining millimeter diameter focusing at a preliminary 7.5 kV beam energy. (orig.)

  17. Proposal for a slow positron facility at Jefferson National Laboratory

    Science.gov (United States)

    Mills, Allen P.

    2018-05-01

    One goal of the JPos-17 International Workshop on Physics with Positrons was to ascertain whether it would be a good idea to expand the mission of the Thomas Jefferson National Accelerator Facility (JLab) to include science with low energy (i.e. "slow") spin polarized positrons. It is probably true that experimentation with slow positrons would potentially have wide-ranging benefits comparable to those obtained with neutron and x-ray scattering, but it is certain that the full range of these benefits will never be fully available without an infrastructure comparable to that of existing neutron and x-ray facilities. The role for Jefferson Laboratory would therefore be to provide and maintain (1) a dedicated set of machines for making and manipulating high intensity, high brightness beams of polarized slow positrons; (2) a suite of unique and easily used instruments of wide utility that will make efficient use of the positrons; and (3) a group of on-site positron scientists to provide scientific leadership, instrument development, and user support. In this note some examples will be given of the science that might make a serious investment in a positron facility worthwhile. At the same time, the lessons learned from various proposed and successful positron facilities will be presented for consideration.

  18. A combined matrix isolation spectroscopy and cryosolid positron moderation apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Molek, Christopher D.; Michael Lindsay, C.; Fajardo, Mario E. [Air Force Research Laboratory, Munitions Directorate, Ordnance Division, Energetic Materials Branch, AFRL/RWME, 2306 Perimeter Road, Eglin AFB, Florida 32542-5910 (United States)

    2013-03-15

    We describe the design, construction, and operation of a novel apparatus for investigating efficiency improvements in thin-film cryogenic solid positron moderators. We report results from solid neon, argon, krypton, and xenon positron moderators which illustrate the capabilities and limitations of our apparatus. We integrate a matrix isolation spectroscopy diagnostic within a reflection-geometry positron moderation system. We report the optical thickness, impurity content, and impurity trapping site structures within our moderators determined from infrared absorption spectra. We use a retarding potential analyzer to modulate the flow of slow positrons, and report positron currents vs. retarding potential for the different moderators. We identify vacuum ultraviolet emissions from irradiated Ne moderators as the source of spurious signals in our channel electron multiplier slow positron detection channel. Our design is also unusual in that it employs a sealed radioactive Na-22 positron source which can be translated relative to, and isolated from, the cryogenic moderator deposition substrate. This allows us to separate the influences on moderator efficiency of surface contamination by residual gases from those of accumulated radiation damage.

  19. Production of slow-positron beams with an electron linac

    International Nuclear Information System (INIS)

    Howell, R.H.; Alvarez, R.A.; Stanek, M.

    1982-01-01

    Intense, pulsed beams of low-energy positrons have been produced by a high-energy beam from an electron linac. The production efficiency for low-energy positrons has been determined for electrons with 60 to 120 MeV energy, low-energy positron beams from a linac can be of much higher intensity than those beams currently derived from radioactive sources

  20. Development of positron diffraction and holography at LLNL

    International Nuclear Information System (INIS)

    Hamza, A.; Asoka-Kumar, P.; Stoeffl, W.; Howell, R.; Miller, D.; Denison, A.

    2003-01-01

    A low-energy positron diffraction and holography spectrometer is currently being constructed at the Lawrence Livermore National Laboratory (LLNL) to study surfaces and adsorbed structures. This instrument will operate in conjunction with the LLNL intense positron beam produced by the 100 MeV LINAC allowing data to be acquired in minutes rather than days. Positron diffraction possesses certain advantages over electron diffraction which are discussed. Details of the instrument based on that of low-energy electron diffraction are described

  1. Positron lifetime spectroscopy of internally oxidised Ag-In alloys

    International Nuclear Information System (INIS)

    Wegner, D.; Lieb, K.P.

    1989-01-01

    The effects of In 2 O 3 precipitates on positron lifetimes after internal oxidation of α-Ag-In alloys have been investigated. A positron trap associated with the lifetime τ 205(3) ps was detected. On the basis of the experimental results obtained for different oxidation kinetics parameters, a trapping model is proposed according to which positrons thermalised in a dislocation field around oxide precipitates are trapped at the oxide/metal phase boundary. The transition from internal to external oxidation of Ag-In was also studied. The positron lifetime in In 2 O 3 was measured to be τ = 263(8) ps. (author)

  2. Observation of Beam Size Flip-Flop in PEP-II

    International Nuclear Information System (INIS)

    Holtzapple, Robert luther

    2002-01-01

    The asymmetric B-factory, PEP-II, has delivered a peak luminosity of 4.6 x 10 33 cm -2 s -1 with less than half the design number of bunches, requiring a luminosity per bunch crossing more than three times larger than the design. As a result, strong beam-beam effects are present. The strong beam-beam forces between colliding electron and positron bunches can result in a ''flip-flop'' of the transverse beam size of some bunches. Focusing on one positron-electron colliding bunch pair, a flip-flop occurs when the transverse size of the positron bunch shrinks and the electron bunch grows. The flip-flop accounts for a reduction in luminosity, a lower positron lifetime, and increased background in the BABAR detector. The flip-flop phenomenon occurs not for all of the colliding bunches, but for the bunches at the front of a mini-train. Once a colliding pair has flipped to its reduced luminosity state it can be changed back to its normal state by raising the horizontal tune in the low-energy ring (LER, positrons) by 0.01. Afterwards the LER x-tune can be reduced nearly back to its original point, resulting in higher luminosity. These observations were verified and quantified with a new time-gated camera with a resolution of 2 ns, making it possible to observe single bunches

  3. Positron and positronium annihilation in low-dielectric-constant films studied by a pulsed positron beam

    International Nuclear Information System (INIS)

    Suzuki, R.; Ohdaira, T.; Kobayashi, Y.; Ito, K.; Yu, R.S.; Shioya, Y.; Ichikawa, H.; Hosomi, H.; Ishikiriyama, K.; Shirataki, H.; Matsuno, S.; Xu, J.

    2004-01-01

    Positron and positronium annihilation in porous low-dielectric-constant (low-k) films deposited by plasma-enhanced chemical vapor deposition (PECVD) and spin-on dielectric (SOD) have been investigated by means of positron annihilation lifetime spectroscopy (PALS) and age-momentum correlation (AMOC) spectroscopy with a pulsed slow positron beam. The ortho-positronium (o-Ps) lifetime strongly depends on the deposition condition. In general, PECVD low-k films have shorter o-Ps lifetimes than SOD low-k films, indicating PECVD low-k films have smaller pores. Since o-Ps diffusion and escaping from the surface occurs in most of porous SOD films, three-gamma annihilation measurement is important. To investigate o-Ps behavior in SOD films, we have carried out two-dimensional (2D) PALS measurement, which measures annihilation time and pulse-height of the scintillation detector simultaneously. Monte-Carlo simulation of the o-Ps diffusion and escaping in porous films has been carried out to simulate the 2D-PALS results. (orig.)

  4. Bremsstrahlung Based Positron Annihilation Spectroscopy for Material Defect Analysis

    International Nuclear Information System (INIS)

    Selim, F.A.; Wells, D.P.; Harmon, F.; Kwofie, J.; Lancaster, G.; Jones, J.L.

    2003-01-01

    The Idaho Accelerator Center (IAC) has developed new techniques for Positron Annihilation Spectroscopy (PAS) using highly penetrating γ-rays to create positrons inside the material via pair production. γ-Ray induced positron annihilation spectroscopy can provide highly penetrating probes for material characterization and defect analysis. Bremsstrahlung beams from small, pulsed electron Linacs (6 MeV) have been used to bombard the materials to generate positrons, which annihilate with the material electrons emitting 511 keV radiation. We have also synchronized bremsstrahlung pulses with laser irradiation pulses to study dynamic structural changes in material. In addition, we have developed another method using (p,γ) reactions from a 2 MeV proton beam, which induce coincident γ-rays to perform positron life-time spectroscopy. We have showed the feasibility of extending PAS into thick samples and a wide variety of materials and industrial applications

  5. On new developments in the physics of positron swarms

    International Nuclear Information System (INIS)

    Petrovic, Z Lj; Bankovic, A; Dujko, S; Marjanovic, S; Suvakov, M; Malovic, G; Marler, J P; Buckman, S J; White, R D; Robson, R E

    2010-01-01

    Recently a new wave of swarm studies of positrons was initiated based on more complete scattering cross section sets. Initially some interesting and new physics was discovered, most importantly negative differential conductivity (NDC) that occurs only for the bulk drift velocity while it does not exist for the flux property. However the ultimate goal was to develop tools to model positron transport in realistic applications and the work that is progressing along these lines is reviewed here. It includes studies of positron transport in molecular gases, thermalization in generic swarm situations and in realistic gas filled traps and transport of positrons in crossed electric and magnetic fields. Finally we have extended the same technique of simulation (Monte Carlo) to studies of thermalization of positronium molecule. In addition, recently published first steps towards including effects of dense media on positron transport are summarized here.

  6. Positron annihilation in corrosion protective polymeric coatings. Pt. 2

    International Nuclear Information System (INIS)

    Szeles, C.; Vertes, A.; White, M.L.; Leidheiser, H. Jr.; Lehigh Univ., Bethlehem, PA

    1988-01-01

    Positron annihilation was studied in four commercial polymeric coatings on iron. Positron lifetime measurements were performed before and after exposure of the coatings to boiling water for 1 h. A correlation was observed between the effect of water exposure on the lifetime spectra and the protective properties of the coatings when exposed to 0.1M sulfuric acid at 60 0 C for 1010 h. The coatings that provided good corrosion protection in the acid showed minor changes in the positron lifetime spectra upon exposure to water. The spectra of coatings that showed poor corrosion protection in the acid showed minor changes in the positron lifetime spectra upon exposure to water. The spectra of coatings that showed poor corrosion protection, on the other hand, exhibited considerable changes in the positron lifetime spectra upon exposure to water. (orig.)

  7. F-18-fluorodeoxyglucose-positron emission tomography in colorectal cancer

    International Nuclear Information System (INIS)

    Joerg, L.; Langsteger, W.

    2002-01-01

    Whole-body positron emission tomography (PET) with the radiolabeled glucose analog F-18-fluorodeoxyglucose (F-18-FDG) is a sensitive diagnostic tool that images tumors based on increased uptake of glucose. Several recent publications have shown that F-18-fluorodeoxyglucose-positron emission tomography is more sensitive than computed-tomography (CT) in detecting colorectal cancer. In patients with increasing CEA (carcinoembryonic antigen) and no evidence of recurrent disease on CT F-18-fluorodeoxyglucose-positron emission tomography often detects recurrent cancer. In all, patient management seems to be changed in about 25 % of patients who undergo F-18-fluorodeoxyglucose-positron emission tomography in addition to standard staging procedure. Limited reports to date on both chemotherapy and radiotherapy support the role of F-18-fluorodeoxyglucose-positron emission tomography in assessing treatment response. Also regarding preoperative staging of primary colorectal cancer the literature is very limited. (author)

  8. 22 Na positron source for annihilation positron spectroscopy

    International Nuclear Information System (INIS)

    Cimpeanu, Catalina; Craciun, Liviu; Dragulescu, Emilian; Dudu, Dorin; Racolta, Petre Mihai; Voiculescu, Dana; Miron, N.

    2005-01-01

    To extend the nuclear physics applications and to perform the study of vacancy - type defects in metals, semiconductors, polymers, etc., we developed new positron annihilation techniques. In line with this goal we started a project for production of positron sources at the IFIN-HH U-120 Cyclotron. We made use of the nuclear reaction: 24 Mg(d,α) 22 Na with deuterons of 13 MeV energy. The paper present the main steps of this procedure which are: establishing the conditions required for 22 NaCl sources, for the parameters of reaction chamber and the characteristics of Mg target, parameters for the irradiation, radiochemical procedures for separation of Na from Mg after irradiation as well as the geometrical and mechanical requirements for the NaCl source. In the e + lifetime measurements the e + 'stop' signals are always provided by gamma - quanta generated by the e + e - annihilation and the 'start' signals are obtained from 'prompt' gamma - quanta emitted by the NaCl source (1.275 MeV photons). The 22 NaCl stock solution obtained by radiochemical separation will be kept in quartz sealed ampoules. (authors)

  9. Electron-positron interactions

    International Nuclear Information System (INIS)

    Wiik, B.; Wolf, G.

    1979-01-01

    This book is an introduction into the physics of electron-positron interactions. After a description of electron-positron storage rings pure electromagnetic e + e - interactions, and the total cross section are considered. Then low energy processes, the production of the J/psi and psi' particles including their radiative decay as well as the search for other narrow vector states are described. Then after the quark model interpretation of J/psi and psi' charmed mesons, the heavy lepton t, and the upsilon resonances are described. Thereafter inclusive hadron production and jet formation is discussed. Finally the next generation of e + e - colliding rings is described, and the first results from PETRA are presented. This book is suited for all physicists, who want to get a general review about e + e - physics. (HSI) 891 HSI/HSI 892 RKD

  10. Positron transport: The plasma-gas interface

    International Nuclear Information System (INIS)

    Marler, J. P.; Petrovic, Z. Lj.; Bankovic, A.; Dujko, S.; Suvakov, M.; Malovic, G.; Buckman, S. J.

    2009-01-01

    Motivated by an increasing number of applications, new techniques in the analysis of electron transport have been developed over the past 30 years or so, but similar methods had yet to be applied to positrons. Recently, an in-depth look at positron transport in pure argon gas has been performed using a recently established comprehensive set of cross sections and well-established Monte Carlo simulations. The key novelty as compared to electron transport is the effect of positronium formation which changes the number of particles and has a strong energy dependence. This coupled with spatial separation by energy of the positron swarm leads to counterintuitive behavior of some of the transport coefficients. Finally new results in how the presence of an applied magnetic field affects the transport coefficients are presented.

  11. Positrons as imaging agents and probes in nanotechnology

    International Nuclear Information System (INIS)

    Smith, Suzanne V

    2009-01-01

    Positron emission tomography (PET) tracks a positron emitting radiopharmaceutical injected into the body and generates a 3-dimensional image of its location. Introduced in the early 70s, it has now developed into a powerful medical diagnostic tool for routine clinical use as well as in drug development. Unrivalled as a highly sensitive, specific and non-invasive imaging tool, PET unfortunately lacks the resolution of Computer Tomography (CT) and Magnetic Resonance Imaging (MRI). As the resolution of PET depends significantly on the energy of the positron incorporated in the radiopharmaceutical and its interaction with its surrounding tissue, there is growing interest in expanding our understanding of how positrons interact at the atomic and molecular level. A better understanding of these interactions will contribute to improving the resolution of PET and assist in the design of better imaging agents. Positrons are also used in Positron Annihilation Lifetime Spectroscopy (PALS) to determine electron density and or presence and incidence of micro- and mesopores (0.1 to 10 nm) in materials. The control of porosity in engineered materials is crucial for applications such as controlled release or air and water resistant films. Equally important to the design of nano and microtechnologies, is our understanding of the microenvironments within these pores and on surfaces. Hence as radiopharmaceuticals are designed to track disease, nuclear probes (radioactive molecules) are synthesized to investigate the chemical properties within these pores. This article will give a brief overview of the present role of positrons in imaging as well as explore its potential to contribute in the engineering of new materials to the marketplace.

  12. The Correlation Between Dislocations and Vacancy Defects Using Positron Annihilation Spectroscopy

    Science.gov (United States)

    Pang, Jinbiao; Li, Hui; Zhou, Kai; Wang, Zhu

    2012-07-01

    An analysis program for positron annihilation lifetime spectra is only applicable to isolated defects, but is of no use in the presence of defective correlations. Such limitations have long caused problems for positron researchers in their studies of complicated defective systems. In order to solve this problem, we aim to take a semiconductor material, for example, to achieve a credible average lifetime of single crystal silicon under plastic deformation at different temperatures using positron life time spectroscopy. By establishing reasonable positron trapping models with defective correlations and sorting out four lifetime components with multiple parameters, as well as their respective intensities, information is obtained on the positron trapping centers, such as the positron trapping rates of defects, the density of the dislocation lines and correlation between the dislocation lines, and the vacancy defects, by fitting with the average lifetime with the aid of Matlab software. These results give strong grounds for the existence of dislocation-vacancy correlation in plastically deformed silicon, and lay a theoretical foundation for the analysis of positron lifetime spectra when the positron trapping model involves dislocation-related defects.

  13. Observation of exclusive electron-positron production in hadron-hadron collisions.

    Science.gov (United States)

    Abulencia, A; Adelman, J; Affolder, T; Akimoto, T; Albrow, M G; Ambrose, D; Amerio, S; Amidei, D; Anastassov, A; Anikeev, K; Annovi, A; Antos, J; Aoki, M; Apollinari, G; Arguin, J-F; Arisawa, T; Artikov, A; Ashmanskas, W; Attal, A; Azfar, F; Azzi-Bacchetta, P; Azzurri, P; Bacchetta, N; Badgett, W; Barbaro-Galtieri, A; Barnes, V E; Barnett, B A; Baroiant, S; Bartsch, V; Bauer, G; Bedeschi, F; Behari, S; Belforte, S; Bellettini, G; Bellinger, J; Belloni, A; Benjamin, D; Beretvas, A; Beringer, J; Berry, T; Bhatti, A; Binkley, M; Bisello, D; Blair, R E; Blocker, C; Blumenfeld, B; Bocci, A; Bodek, A; Boisvert, V; Bolla, G; Bolshov, A; Bortoletto, D; Boudreau, J; Boveia, A; Brau, B; Brigliadori, L; Bromberg, C; Brubaker, E; Budagov, J; Budd, H S; Budd, S; Budroni, S; Burkett, K; Busetto, G; Bussey, P; Byrum, K L; Cabrera, S; Campanelli, M; Campbell, M; Canelli, F; Canepa, A; Carillo, S; Carlsmith, D; Caron, B; Carosi, R; Casarsa, M; Castro, A; Catastini, P; Cauz, D; Cavalli-Sforza, M; Cerri, A; Cerrito, L; Chang, S H; Chen, Y C; Chertok, M; Chiarelli, G; Chlachidze, G; Chlebana, F; Cho, I; Cho, K; Chokheli, D; Chou, J P; Choudalakis, G; Chuang, S H; Chung, K; Chung, W H; Chung, Y S; Ciljak, M; Ciobanu, C I; Ciocci, M A; Clark, A; Clark, D; Coca, M; Compostella, G; Convery, M E; Conway, J; Cooper, B; Copic, K; Cordelli, M; Cortiana, G; Crescioli, F; Almenar, C Cuenca; Cuevas, J; Culbertson, R; Cully, J C; Cyr, D; Daronco, S; D'Auria, S; Davies, T; D'Onofrio, M; Dagenhart, D; de Barbaro, P; Cecco, S De; Deisher, A; Lentdecker, G De; Dell'orso, M; Paoli, F Delli; Demortier, L; Deng, J; Deninno, M; Pedis, D De; Derwent, P F; Giovanni, G P Di; Dionisi, C; Ruzza, B Di; Dittmann, J R; Dituro, P; Dörr, C; Donati, S; Donega, M; Dong, P; Donini, J; Dorigo, T; Dube, S; Efron, J; Erbacher, R; Errede, D; Errede, S; Eusebi, R; Fang, H C; Farrington, S; Fedorko, I; Fedorko, W T; Feild, R G; Feindt, M; Fernandez, J P; Field, R; Flanagan, G; Foland, A; Forrester, S; Foster, G W; Franklin, M; Freeman, J C; Furic, I; Gallinaro, M; Galyardt, J; Garcia, J E; Garberson, F; Garfinkel, A F; Gay, C; Gerberich, H; Gerdes, D; Giagu, S; Giannetti, P; Gibson, A; Gibson, K; Gimmell, J L; Ginsburg, C; Giokaris, N; Giordani, M; Giromini, P; Giunta, M; Giurgiu, G; Glagolev, V; Glenzinski, D; Gold, M; Goldschmidt, N; Goldstein, J; Gomez, G; Gomez-Ceballos, G; Goncharov, M; González, O; Gorelov, I; Goshaw, A T; Goulianos, K; Gresele, A; Griffiths, M; Grinstein, S; Grosso-Pilcher, C; Grundler, U; da Costa, J Guimaraes; Gunay-Unalan, Z; Haber, C; Hahn, K; Hahn, S R; Halkiadakis, E; Hamilton, A; Han, B-Y; Han, J Y; Handler, R; Happacher, F; Hara, K; Hare, M; Harper, S; Harr, R F; Harris, R M; Hartz, M; Hatakeyama, K; Hauser, J; Heijboer, A; Heinemann, B; Heinrich, J; Henderson, C; Herndon, M; Heuser, J; Hidas, D; Hill, C S; Hirschbuehl, D; Hocker, A; Holloway, A; Hou, S; Houlden, M; Hsu, S-C; Huffman, B T; Hughes, R E; Husemann, U; Huston, J; Incandela, J; Introzzi, G; Iori, M; Ishizawa, Y; Ivanov, A; Iyutin, B; James, E; Jang, D; Jayatilaka, B; Jeans, D; Jensen, H; Jeon, E J; Jindariani, S; Jones, M; Joo, K K; Jun, S Y; Jung, J E; Junk, T R; Kamon, T; Karchin, P E; Kato, Y; Kemp, Y; Kephart, R; Kerzel, U; Khotilovich, V; Kilminster, B; Kim, D H; Kim, H S; Kim, J E; Kim, M J; Kim, S B; Kim, S H; Kim, Y K; Kimura, N; Kirsch, L; Klimenko, S; Klute, M; Knuteson, B; Ko, B R; Kondo, K; Kong, D J; Konigsberg, J; Korytov, A; Kotwal, A V; Kovalev, A; Kraan, A C; Kraus, J; Kravchenko, I; Kreps, M; Kroll, J; Krumnack, N; Kruse, M; Krutelyov, V; Kubo, T; Kuhlmann, S E; Kuhr, T; Kusakabe, Y; Kwang, S; Laasanen, A T; Lai, S; Lami, S; Lammel, S; Lancaster, M; Lander, R L; Lannon, K; Lath, A; Latino, G; Lazzizzera, I; Lecompte, T; Lee, J; Lee, J; Lee, Y J; Lee, S W; Lefèvre, R; Leonardo, N; Leone, S; Levy, S; Lewis, J D; Lin, C; Lin, C S; Lindgren, M; Lipeles, E; Lister, A; Litvintsev, D O; Liu, T; Lockyer, N S; Loginov, A; Loreti, M; Loverre, P; Lu, R-S; Lucchesi, D; Lujan, P; Lukens, P; Lungu, G; Lyons, L; Lys, J; Lysak, R; Lytken, E; Mack, P; Macqueen, D; Madrak, R; Maeshima, K; Makhoul, K; Maki, T; Maksimovic, P; Malde, S; Manca, G; Margaroli, F; Marginean, R; Marino, C; Marino, C P; Martin, A; Martin, M; Martin, V; Martínez, M; Maruyama, T; Mastrandrea, P; Masubuchi, T; Matsunaga, H; Mattson, M E; Mazini, R; Mazzanti, P; McFarland, K S; McIntyre, P; McNulty, R; Mehta, A; Mehtala, P; Menzemer, S; Menzione, A; Merkel, P; Mesropian, C; Messina, A; Miao, T; Miladinovic, N; Miles, J; Miller, R; Mills, C; Milnik, M; Mitra, A; Mitselmakher, G; Miyamoto, A; Moed, S; Moggi, N; Mohr, B; Moore, R; Morello, M; Fernandez, P Movilla; Mülmenstädt, J; Mukherjee, A; Muller, Th; Mumford, R; Murat, P; Nachtman, J; Nagano, A; Naganoma, J; Nakano, I; Napier, A; Necula, V; Neu, C; Neubauer, M S; Nielsen, J; Nigmanov, T; Nodulman, L; Norniella, O; Nurse, E; Oh, S H; Oh, Y D; Oksuzian, I; Okusawa, T; Oldeman, R; Orava, R; Osterberg, K; Pagliarone, C; Palencia, E; Papadimitriou, V; Paramonov, A A; Parks, B; Pashapour, S; Patrick, J; Pauletta, G; Paulini, M; Paus, C; Pellett, D E; Penzo, A; Phillips, T J; Piacentino, G; Piedra, J; Pinera, L; Pinfold, J; Pitts, K; Plager, C; Pondrom, L; Portell, X; Poukhov, O; Pounder, N; Prakoshyn, F; Pronko, A; Proudfoot, J; Ptohos, F; Punzi, G; Pursley, J; Rademacker, J; Rahaman, A; Ranjan, N; Rappoccio, S; Reisert, B; Rekovic, V; Renton, P; Rescigno, M; Richter, S; Rimondi, F; Ristori, L; Robson, A; Rodrigo, T; Rogers, E; Rolli, S; Roser, R; Rossi, M; Rossin, R; Ruiz, A; Russ, J; Rusu, V; Saarikko, H; Sabik, S; Safonov, A; Sakumoto, W K; Salamanna, G; Saltó, O; Saltzberg, D; Sánchez, C; Santi, L; Sarkar, S; Sartori, L; Sato, K; Savard, P; Savoy-Navarro, A; Scheidle, T; Schlabach, P; Schmidt, E E; Schmidt, M P; Schmitt, M; Schwarz, T; Scodellaro, L; Scott, A L; Scribano, A; Scuri, F; Sedov, A; Seidel, S; Seiya, Y; Semenov, A; Sexton-Kennedy, L; Sfyrla, A; Shapiro, M D; Shears, T; Shepard, P F; Sherman, D; Shimojima, M; Shochet, M; Shon, Y; Shreyber, I; Sidoti, A; Sinervo, P; Sisakyan, A; Sjolin, J; Slaughter, A J; Slaunwhite, J; Sliwa, K; Smith, J R; Snider, F D; Snihur, R; Soderberg, M; Soha, A; Somalwar, S; Sorin, V; Spalding, J; Spinella, F; Spreitzer, T; Squillacioti, P; Stanitzki, M; Staveris-Polykalas, A; Denis, R St; Stelzer, B; Stelzer-Chilton, O; Stentz, D; Strologas, J; Stuart, D; Suh, J S; Sukhanov, A; Sun, H; Suzuki, T; Taffard, A; Takashima, R; Takeuchi, Y; Takikawa, K; Tanaka, M; Tanaka, R; Tecchio, M; Teng, P K; Terashi, K; Thom, J; Thompson, A S; Thomson, E; Tipton, P; Tiwari, V; Tkaczyk, S; Toback, D; Tokar, S; Tollefson, K; Tomura, T; Tonelli, D; Torre, S; Torretta, D; Tourneur, S; Trischuk, W; Tsuchiya, R; Tsuno, S; Turini, N; Ukegawa, F; Unverhau, T; Uozumi, S; Usynin, D; Vallecorsa, S; van Remortel, N; Varganov, A; Vataga, E; Vázquez, F; Velev, G; Veramendi, G; Veszpremi, V; Vidal, R; Vila, I; Vilar, R; Vine, T; Vollrath, I; Volobouev, I; Volpi, G; Würthwein, F; Wagner, P; Wagner, R G; Wagner, R L; Wagner, J; Wagner, W; Wallny, R; Wang, S M; Warburton, A; Waschke, S; Waters, D; Wester, W C; Whitehouse, B; Whiteson, D; Wicklund, A B; Wicklund, E; Williams, G; Williams, H H; Wilson, P; Winer, B L; Wittich, P; Wolbers, S; Wolfe, C; Wright, T; Wu, X; Wynne, S M; Yagil, A; Yamamoto, K; Yamaoka, J; Yamashita, T; Yang, C; Yang, U K; Yang, Y C; Yao, W M; Yeh, G P; Yoh, J; Yorita, K; Yoshida, T; Yu, G B; Yu, I; Yu, S S; Yun, J C; Zanello, L; Zanetti, A; Zaw, I; Zhang, X; Zhou, J; Zucchelli, S

    2007-03-16

    We present the first observation of exclusive e(+)e(-) production in hadron-hadron collisions, using pp[over] collision data at (square root) s = 1.96 TeV taken by the run II Collider Detector at Fermilab, and corresponding to an integrated luminosity of 532 pb(-1). We require the absence of any particle signatures in the detector except for an electron and a positron candidate, each with transverse energy E(T) > 5 GeV and pseudorapidity |eta| p + e(+)e(-) + p[over] through two-photon exchange. The measured cross section is 1.6(-0.3)(+0.5)(stat) +/- 0.3(syst) pb. This agrees with the theoretical prediction of 1.71+/-0.01 pb.

  14. Measurement of characteristic X-rays by positron impact

    International Nuclear Information System (INIS)

    Nagashima, Y.; Saito, F.; Itoh, Y.; Goto, A.; Hyodo, T.

    2004-01-01

    An X-ray detector with thin Si(Li) crystals has been fabricated and employed to detect the characteristic X-rays by positron impact. Use of thin detector crystals is essential for the measurements of the characteristic X-rays induced by positron impact. Otherwise the background produced in the crystals by the annihilation γ-rays is too large to isolate the X-ray peaks. The data has been analyzed to obtain the inner-shell ionization cross sections by positron impact. (orig.)

  15. Positron emission tomography - a new approach to brain chemistry

    International Nuclear Information System (INIS)

    Jacobson, H.G.

    1988-01-01

    Positron emission tomography permits examination of the chemistry of the brain in living beings. Until recently, positron emission tomography had been considered a research tool, but it is rapidly moving into clinical practice. This report describes the uses and applications of positron emission tomography in examinations of patients with strokes, epilepsy, malignancies, dementias, and schizophrenia and in basic studies of synaptic neurotransmission

  16. Measurement of positron range in matter in strong magnetic fields

    International Nuclear Information System (INIS)

    Hammer, B.E.; Christensen, N.L.

    1995-01-01

    Positron range is one factor that places a limitation on Positron Emission Tomography (PET) resolution. The distance a positron travels through matter before it annihilates with an electron is a function of its initial energy and the electron density of the medium. A strong magnetic field limits positron range when momentum components are transverse to the field. Measurement of positron range was determined by deconvolving the effects of detector response and radioactive distribution from the measured annihilation spread function. The annihilation spread function for a 0.5 mm bead of 68 Ga was measured with 0.2 and 1.0 mm wide slit collimators. Based on the annihilation spread function FWHM (Full Width at Half Maximum) for a 1.0 mm wide slit the median positron range in tissue equivalent material is 0.87, 0.50, 0.22 mm at 0, 5.0 and 9.4 T, respectively

  17. Measurement of positron reemission from thin single-crystal W(100) films

    International Nuclear Information System (INIS)

    Chen, D.M.; Lynn, K.G.; Pareja, R.; Nielsen, B.

    1985-01-01

    Epitaxial thin single-crystal (100) tungsten films 1000, 2500, and 5000 A thick have been fabricated by high-vacuum electron-beam evaporation. These films were subsequently used as thin-film moderators for the study of the positron-transmission-reemission process with a variable-energy (0--80 keV) monoenergetic positron beam in an ultrahigh-vacuum system. The films were shown to be routinely cleanable by heating first in oxygen (10 -6 Torr) and then in vacuum (10 -9 Torr). Transmission and back reemission of slow positrons from these surfaces was observed. The positron work function, phi/sub +/ has been determined to be approx. =3.0 eV ( +- 0.3 eV). The transmission slow positrons were emitted in a narrow cone with a full width at half maximum of approx. =30 0 consistent with the angular distribution of back-reemission positrons. The reemitted yields as a function of incident positron energy were found to be very different between forward reemission and back reemission. The maximum forward-reemission yields were 18% for 1000-A-thick W film and 12% for 2500-A-thick W film at 5 and 10 keV optimum incident positron energies, respectively. These results show that one can use thin single-crystal tungsten films as positron moderators or remoderators

  18. Threshold law for positron-atom impact ionisation

    International Nuclear Information System (INIS)

    Temkin, A.

    1982-01-01

    The threshold law for ionisation of atoms by positron impact is adduced in analogy with the author's approach to the electron-atom ionisation. It is concluded the Coulomb-dipole region of potential gives the essential part of the interaction in both cases and leads to the same kind of result: a modulated linear law. An additional process which enters positron ionisation is positronium formation in the continuum, but that will not dominate the threshold yield. The result is in sharp contrast to the positron threshold law as recently derived by Klar (J. Phys. B.; 14:4165 (1981)) on the basis of a Wannier-type (Phys. Rev.; 90:817 (1953)) analysis. (author)

  19. Application of positron annihilation techniques for semiconductor studies

    International Nuclear Information System (INIS)

    Karwasz, G.P.; Zecca, A.; Brusa, R.S.; Pliszka, D.

    2004-01-01

    Positron annihilation techniques, being non-destructive, allowing depth profiling down to a few micrometers and detecting open-volume defects (vacancies, dislocations etc.) at single ppm concentrations constitute a valuable and complementary method, compared to other solid-state-physics studies. We give examples of investigation in the field of semiconductors with different techniques, both with and without use of positron low-energy beams. The Doppler broadening of the 511 keV annihilation line method and the slow positron beam were used to study helium-implanted silicon and the surface reduction processes in semiconducting glasses. The positron lifetime technique and coincidence spectra of the Doppler broadening were used for systematic studies of metals and semiconductors. Doppler-coincidence method was then used to identify the kinetics of oxygen precipitates in Czochralski-grown silicon

  20. Developments on positron scattering experiments including beam production and detection

    International Nuclear Information System (INIS)

    Selim, F.A.; Golovchenko, J.A.

    2001-01-01

    Positron scattering and channeling experiments require high quality (low emittance) beams. A new electrostatic optics system for extracting positrons from a moderator is presented. The system features improved efficiency of focusing and beam transport of moderated positrons emitted with angular spreads up to ± 30 , with good phase space characteristics. The presented optics also provides a high degree of freedom in controlling exit beam trajectories. The system has been installed in the LLNL Pelletron accelerator and showed great enhancement on the beam quality. On the detection side, image plates were used to measure the angular distributions of positrons transmitted through the gold crystals. The measurements demonstrate the advantages of image plates as quantitative position sensitive detectors for positrons. (orig.)

  1. Positron prevacancy effects in pure annealed metals

    International Nuclear Information System (INIS)

    Smedskjaer, L.C.

    1981-06-01

    The low-temperature prevacancy effects sometimes observed with positrons in well-annealed high-purity metals are discussed. It is shown that these effects are not experimental artifacts, but are due to trapping of the positrons. It is suggested that dislocations are responsible for these trapping effects. 46 references, 5 figures

  2. A multicrystal positron scanner for quantitative studies with positron-emitting radionuclides

    International Nuclear Information System (INIS)

    Ostertag, H.; Kuebler, W.; Kubesch, R.; Lorenz, W.J.

    1981-01-01

    A non-tomographic multicrystal whole-body scanner for quantitative positron imaging has been designed. The detector system consists of 64 coincidence detector pairs arranged in two opposing detector banks. NaI crystals of 38-mm diameter and 76-mm length are used. The patient moves linearly between the stationary transverse detector banks. The scanning area is 64-cm wide and up to 192-cm long. The spatial resolution is 2 cm at a sampling distance of 1 cm. The plane sensitivity amounts to 6400 counts/s for a pure positron emitter of 1 μCi/cm 2 . The accuracy of quantitative activity measurements is better than +- 15% for activities up to a few μCi/cm 2 . The design of the instrument, and its capabilities and limitations, are discussed. Initial experimental and clinical results are presented. (author)

  3. Characterization of a transmission positron/positronium converter for antihydrogen production

    Science.gov (United States)

    Aghion, S.; Amsler, C.; Ariga, T.; Bonomi, G.; Brusa, R. S.; Caccia, M.; Caravita, R.; Castelli, F.; Cerchiari, G.; Comparat, D.; Consolati, G.; Demetrio, A.; Di Noto, L.; Doser, M.; Ereditato, A.; Evans, C.; Ferragut, R.; Fesel, J.; Fontana, A.; Gerber, S.; Giammarchi, M.; Gligorova, A.; Guatieri, F.; Haider, S.; Hinterberger, A.; Holmestad, H.; Kellerbauer, A.; Krasnický, D.; Lagomarsino, V.; Lansonneur, P.; Lebrun, P.; Malbrunot, C.; Mariazzi, S.; Matveev, V.; Mazzotta, Z.; Müller, S. R.; Nebbia, G.; Nedelec, P.; Oberthaler, M.; Pacifico, N.; Pagano, D.; Penasa, L.; Petracek, V.; Povolo, L.; Prelz, F.; Prevedelli, M.; Ravelli, L.; Resch, L.; Rienäcker, B.; Robert, J.; Røhne, O. M.; Rotondi, A.; Sacerdoti, M.; Sandaker, H.; Santoro, R.; Scampoli, P.; Simon, M.; Smestad, L.; Sorrentino, F.; Testera, G.; Tietje, I. C.; Widmann, E.; Yzombard, P.; Zimmer, C.; Zmeskal, J.; Zurlo, N.; Andersen, S. L.; Chevallier, J.; Uggerhøj, U. I.; Lyckegaard, F.

    2017-09-01

    In this work a characterization study of forward emission from a thin, meso-structured silica positron/positronium (Ps) converter following implantation of positrons in light of possible antihydrogen production is presented. The target consisted of a ∼1 μm thick ultraporous silica film e-gun evaporated onto a 20 nm carbon foil. The Ps formation and emission was studied via Single Shot Positron Annihilation Lifetime Spectroscopy measurements after implantation of pulses with 3 - 4 ·107 positrons and 10 ns temporal width. The forward emission of implanted positrons and secondary electrons was investigated with a micro-channel plate - phosphor screen assembly, connected either to a CCD camera for imaging of the impinging particles, or to a fast photomultiplier tube to extract information about their time of flight. The maximum Ps formation fraction was estimated to be ∼10%. At least 10% of the positrons implanted with an energy of 3.3 keV are forward-emitted with a scattering angle smaller than 50° and maximum kinetic energy of 1.2 keV. At least 0.1-0.2 secondary electrons per implanted positron were also found to be forward-emitted with a kinetic energy of a few eV. The possible application of this kind of positron/positronium converter for antihydrogen production is discussed.

  4. NMF on positron emission tomography

    DEFF Research Database (Denmark)

    Bödvarsson, Bjarni; Hansen, Lars Kai; Svarer, Claus

    2007-01-01

    In positron emission tomography, kinetic modelling of brain tracer uptake, metabolism or binding requires knowledge of the cerebral input function. Traditionally, this is achieved with arterial blood sampling in the arm or as shown in (Liptrot, M, et al., 2004) by non-invasive K-means clustering....... We propose another method to estimate time-activity curves (TAC) extracted directly from dynamic positron emission tomography (PET) scans by non-negative matrix factorization (NMF). Since the scaling of the basis curves is lost in the NMF the estimated TAC is scaled by a vector alpha which...

  5. Positron emission tomography in oncology

    International Nuclear Information System (INIS)

    Anon.

    1988-01-01

    This report describes the current and potential uses of positron emission tomography in clinical medicine and research related to oncology. Assessment will be possible of metabolism and physiology of tumors and their effects on adjacent tissues. Specific probes are likely to be developed for target sites on tumors, including monoclonal antibodies and specific growth factors that recognize tumors. To date, most oncological applications of positron emission tomography tracers have been qualitative; in the future, quantitative metabolic measurements should aid in the evaluation of tumor biology and response to treatment

  6. Electron and positron interaction with pyrimidine: A theoretical investigation

    Science.gov (United States)

    Sinha, Nidhi; Antony, Bobby

    2018-03-01

    Pyrimidine (C4H4N2) is considered as the building block of nucleobases, viz., cytosine, thymine and uracil. They provide a blueprint for probing the scattering of radiation by DNA and RNA bases. In this article, we report the elastic and total scattering cross-sections for electron and positron scattering from the pyrimidine molecule, employing a spherical complex optical potential (SCOP) formalism for an extensive energy range of 10 eV to 5 keV. In the case of positron scattering, the original SCOP formalism is modified to adequately solve the positron-target dynamics. Moreover, a reasonable agreement is observed between the present results and other available datasets, for both electron and positron scattering. The cross-sections for electron and positron impact scattering by pyrimidine are necessary input data for codes that seek to simulate radiation damage, and hence are useful to model biomolecular systems.

  7. Design of an intense positron source for linear colliders

    International Nuclear Information System (INIS)

    Ida, H.; Yamada, K.; Funahashi, Y.

    1994-01-01

    The Japan Linear Collider (JLC) requires an intense positron source of 8x10 11 particles per rf-pulse. A computer simulation reveals the possibility of such an intense positron source using 'conventional' technology. In order to relax the limitation of the incident electron energy density due to thermal stress in the converter target, the incident beam radius is enlarged within the range so as not to reduce the positron capture efficiency. A pre-damping ring and beam transport system to the pre-damping ring, which have a large transverse acceptance, play important roles for a high capture efficiency. A prototype positron source has been designed and installed at downstream of 1.54 GeV S-band linac in Accelerator Test Facility (ATF) in order to carry out experiments to develop the essential technology for JLC. The simulated results will be tested in experiments with the prototype positron source. (author)

  8. Search for positron anisotropies in cosmic rays with AMS

    Energy Technology Data Exchange (ETDEWEB)

    Machate, Fabian [1. Physikalisches Institut B, RWTH Aachen University (Germany)

    2016-07-01

    The Alpha Magnetic Spectrometer (AMS-02) on the International Space Station has observed a significant excess of cosmic ray positrons over the background expected from secondary production at energies above 10 GeV. Nearby pulsars and annihilating dark matter particles as a primary source of electrons and positrons have been discussed as an explanation. A possible way of distinguishing between pulsar and dark matter origin is the measurement of dipole anisotropies in the positron flux or the positron to electron ratio. Any anisotropy will be reduced by diffusion in galactic magnetic fields to below the percent level. AMS-02 is the leading space-based experiment for cosmic ray detection and well suited for this search. A new analysis procedure for anisotropies using an event sample with large acceptance is presented. It relies on the ability of the Transition Radiation Detector (TRD) to separate positrons from the proton background.

  9. Variable-energy positron-beam studies of Ni implanted with He

    International Nuclear Information System (INIS)

    Lynn, K.G.; Chen, D.M.; Nielsen, B.; Pareja, R.; Myers, S.

    1986-01-01

    Variable-energy positron-beam studies have been made on well-annealed polycrystalline Ni samples implanted with 30-, 90-, and 180-keV 4 He ions. The positron-annihilation characteristics were measured with a solid-state Ge detector at a number of different incident-positron energies and after isochronal annealing at various temperatures. The Doppler broadening of the annihilation photons was found to be strongly influenced by the 4 He implantations. The data indicate that trapping of the positrons occurred predominantly at small He bubbles. The variation of the broadening with incident-positron energy was sensitive to the depth distribution of the traps. A diffusion model assuming a square concentration-defect profile was developed and analytically fitted to the parametrized momentum data. These fitted results were compared to Monte Carlo range calculations for 4 He in Ni, and fairly good agreement was found. This investigation demonstrates the capabilities of positron annihilation for nondestructive depth profiling in ion-implanted systems. In addition, it establishes parallels between the trapping behavior of positrons and that reported elsewhere for hydrogen, thereby augmenting the present level of understanding of the technologically important trapping of hydrogen by the bubbles

  10. Bremsstrahlung pair-production of positrons with low neutron background

    International Nuclear Information System (INIS)

    Lessner, E.

    1998-01-01

    Minimization of component activation is highly desirable at accelerator-based positron sources. Electrons in the 8- to 14-MeV energy range impinging on a target produce photons energetic enough to create electron-positron pairs; however, few of the photons are energetic enough to produce photoneutrons. Slow positron production by low-energy electrons impinging on a multilayer tungsten target with and without electromagnetic extraction between the layers was studied by simulation. The neutron background from 14-MeV electrons is expected to be significantly lower than that encountered with higher-energy electron beams. Numerical results are presented and some ideas for a low-activation slow-positron source are discussed

  11. Muon, positron and antiproton interactions with atoms and molecules

    Energy Technology Data Exchange (ETDEWEB)

    Armour, Edward A G, E-mail: edward.armour@nottingham.ac.u [School of Mathematical Sciences, University of Nottingham, Nottingham NG7 2RD (United Kingdom)

    2010-04-01

    In this paper, a description is given of some interesting processes involving the interaction of a muon, a positron, or an antiproton with atoms and molecules. The process involving a muon is the resonant formation of the muonic molecular ion, dt{mu}, in the muon catalyzed fusion cycle. In the case of a positron, the process considered is positron annihilation in low-energy positron scattering by the hydrogen molecule. The antiproton is considered as the nucleus of an antihydrogen atom interacting with simple atoms. Attention is given to antiproton annihilation through the strong interaction. An outline is given of proposed tests of fundamental physics to be carried out using antihydrogen.

  12. Implantation profile of low-energy positrons in solids

    International Nuclear Information System (INIS)

    Asoka-Kumar, P.; Lynn, K.G.

    1990-01-01

    A simple form for an implantation profile of monoenergetic, low-energy (1--10 keV) positrons in solids is presented. Materials studied include aluminum, copper, molybdenum, palladium, and gold with atomic number ranging from 13 to 79. A simple set of parameters can describe the currently used Makhov profile in slow positron studies of solids. We provide curves and tables for the parameters that can be used to describe the implantation profiles of positrons in any material with atomic number in between 13 and 79

  13. Positron cross-field transport due to quasibound states of antihydrogen

    International Nuclear Information System (INIS)

    Ahat, Y.; Correa, C.E.; Ordonez, C.A.

    2007-01-01

    Within the past few years, experiments have been reported in which antiprotons produced at the CERN Antiproton Decelerator facility were slowed, trapped in nested Penning traps and made to interact with a positron plasma such that antihydrogen was formed. Classical trajectory simulations of the interactions between the antiprotons and positrons have been reported to indicate that positive-energy, quasibound states of antihydrogen can form at a rate that exceeds the rate of formation of stable Rydberg states. The formation of quasibound states may affect the rate of diffusion of positrons across the magnetic field that confines them in the nested Penning trap. Simulations indicate that a binary interaction associated with the formation and disintegration of a quasibound state can cause a shift of the positron's guiding center that is much larger than the positron cyclotron radius before the interaction. A theory is presented that describes positron cross-magnetic-field diffusion due to quasibound states of antihydrogen

  14. Basic principles of 18F-fluoro-deoxyglucose positron emission tomography

    International Nuclear Information System (INIS)

    Standke, R.

    2002-01-01

    Positron emission tomography uses photons to receive regional information about dynamic, physiologic, and biochemical processes in the living body. A positron decay is measured indirectly by the simultaneous registration of both gamma rays created by the annihilation. The event is counted, if two directly opposite located detectors register gamma rays in coincidence. Unfortunately the detectors of a positron emission tomography system do not register only true coincident events. There are also scattered and random coincidences. Different types of positron tomographs are presented and scintillation crystals, which are in use for positron emission tomography are discussed. The 2D- and 3D-acquisition methods are described as well as preprocessing methods, such as correction for attenuation, scatter and dead time. For quantification the relative parameter standard uptake value (SUV) is explained. Finally hybrid systems, such as combined positron emission tomography/computed tomography scanners and the use of computed tomography data for attenuation correction are introduced. (author)

  15. Positron study of negative charge states in order-disorder ferroelectrics

    Energy Technology Data Exchange (ETDEWEB)

    Troev, T.; Berovsky, K.; Peneva, S. [Bulgarian Academy of Sciences, Sofia (Bulgaria). Inst. for Nuclear Research and Nuclear Energy

    2001-07-01

    The positive positron charge opens the possibility for determining the changes in charge states in technologically important order-disorder ferroelectrics. Here we show that dipole polarization disordering within domains affects the positron annihilation mechanism. The positron lifetime parameters in triglycine sulphate (TGS) (NH{sub 3}CH{sub 2}COOH){sub 3}H{sub 2}SO{sub 4}, Rochelle salt (RS) NaKC{sub 4}H{sub 4}O{sub 6}.4H{sub 2}O and Potassium dihydrogen phosphate (KDP) KH{sub 2}PO{sub 4}, at different temperatures and gamma-irradiation doses depend on the charge point defects. The increase of the positron long lifetime component {tau}{sub 2} is proportional to the temperature and gamma-irradiation dose. In gamma irradiated TGS positrons are trapped in defect electron states of oxigen ions of two radicals CH{sub 2}COO{sup -} and NH{sub 3}CHCOO{sup -}. In RS positrons are trapped also in defect electron states of oxygen ions and OH groups. (orig.)

  16. Evidence of shallow positron traps in ion-implanted InP observed by maximum entropy reconstruction of positron lifetime distribution: a test of MELT

    International Nuclear Information System (INIS)

    Chen, Z.Q.; Wang, S.J.

    1999-01-01

    A newly developed maximum entropy method, which was realized by the computer program MELT introduced by Shukla et al., was used to analyze positron lifetime spectra measured in semiconductors. Several simulation studies were done to test the performance of this algorithm. Reliable reconstruction of positron lifetime distributions can be extracted at relatively lower counts, which shows the applicability and superiority of this method. Two positron lifetime spectra measured in ion-implanted p-InP(Zn) at 140 and 280 K, respectively were analyzed by this program. The lifetime distribution differed greatly for the two temperatures, giving direct evidence of the existence of shallow positron traps at low temperature

  17. Present status of positron factory project

    International Nuclear Information System (INIS)

    Okada, S.; Sunaga, H.; Kaneko, H.; Tachibana, H.; Yotsumoto, K.; Okamoto, J.

    1992-01-01

    The Japan Atomic Energy Research Institute, JAERI, has been promoting design studies for the 'Positron Factory', in which linac-based intense monoenergetic positron beams are planned to be applied to advanced materials characterization and new fields of basic research. A tentative goal of the beam intensity is 10 10 s -1 , which is assumed to be realized with an electron linac of 100 kW class with a beam energy around 100 to 150 MeV. We performed a technical survey on the dedicated linac. It confirmed technical feasibility of manufacturing the state-of-the-art machine. We have been carrying out a design study of the target. A new concept of the target design is proposed, which is expected to supply intense slow positron beams simultaneously for multiple beam channels, on the basis of Monte Carlo simulations. (author)

  18. Measurement of the positron polarization at an helical undulator based positron source for the international linear collider ILC. The E-166 experiment at SLAC

    Energy Technology Data Exchange (ETDEWEB)

    Karim, Laihem

    2008-06-05

    A helical undulator based polarized positron source is forseen at a future International Linear Collider (ILC). The E-166 experiment has tested this scheme using a one meter long, short-period, pulsed helical undulator installed in the Final Focus Test Beam (FFTB) at SLAC. A low-emittance 46.6 GeV electron beam passing through this undulator generated circularly polarized photons with energies up to about 8 MeV. The generated photons of several MeV with circular polarization are then converted in a relatively thin target to generate longitudinally polarized positrons. Measurements of the positron polarization have been performed at 5 different energies of the positrons. In addition electron polarization has been determined for one energy point. For a comparison of the measured asymmetries with the expectations detailed simulations were necessary. This required upgrading GEANT4 to include the dominant polarization dependent interactions of electrons, positrons and photons in matter. The measured polarization of the positrons agrees with the expectations and is for the energy point with the highest polarization at 6MeV about 80%. (orig.)

  19. Positron deep-level transient spectroscopy in semi-insulating-GaAs using the positron velocity transient method

    International Nuclear Information System (INIS)

    Tsia, M.; Fung, S.; Beling, C.D.

    2001-01-01

    Recently a new semiconductor defect spectroscopy, namely positron deep level transient spectroscopy (PDLTS) has been proposed that combines the energy selectivity of deep level transient spectroscopy with the structural sensitivity of positron annihilation spectroscopy. This paper focuses on one variant of PDLTS, namely positron velocity PDLTS, which has no sensitivity towards vacancy defects but nevertheless is useful in studying deep levels in semi-insulators. In the present study the electric field within the depletion region of semi-insulating GaAs is monitored through the measurement of the small Doppler shift in the annihilation radiation that comes from this region as a result of positron drift. The drift is the result of an increasing electric field produced by space charge building up from ionizing deep level defects. Doppler shift transients are measured between 50-300 K. The EL2 level emission transients are clearly seen at temperatures around 300 K that yield E C -0.78±0.08eV for the energy of EL2. The EL2 electron capture rate is found to have an activation energy of 0.61±0.08eV which most probably arises from freeze out of conduction electrons. We find the surprising result that emission and capture transients can be seen at temperatures below 200 K. Possible reasons for these transients are discussed. (orig.)

  20. Water-sensitive positron trapping modes in nanoporous magnesium aluminate ceramics

    International Nuclear Information System (INIS)

    Filipecki, J; Ingram, A; Klym, H; Shpotyuk, O; Vakiv, M

    2007-01-01

    The water-sensitive positron trapping modes in nanoporous MgAl 2 O 4 ceramics with a spinel structure are studied. It is shown that water-sorption processes in magnesium aluminate ceramics leads to corresponding increase in positron trapping rates of extended defects located near intergranual boundaries. This catalytic affect has reversible nature, being strongly dependent on sorption water fluxes in ceramics. The fixation of all water-dependent positron trapping inputs allow to refine the most significant changes in positron trapping rate of extended defects

  1. Water-sensitive positron trapping modes in nanoporous magnesium aluminate ceramics

    Energy Technology Data Exchange (ETDEWEB)

    Filipecki, J [Institute of Physics of Jan Dlugosz University, 13/15, al. Armii Krajowej, Czestochowa, PL 42201 (Poland); Ingram, A [Opole University of Technology, 75, Ozimska str., Opole, PL 45370 (Poland); Klym, H [Institute of Materials of SRC ' Carat' , 202, Stryjska str., Lviv, UA 79031 (Ukraine); Shpotyuk, O [Institute of Materials of SRC ' Carat' , 202, Stryjska str., Lviv, UA 79031 (Ukraine); Vakiv, M [Institute of Materials of SRC ' Carat' , 202, Stryjska str., Lviv, UA 79031 (Ukraine)

    2007-08-15

    The water-sensitive positron trapping modes in nanoporous MgAl{sub 2}O{sub 4} ceramics with a spinel structure are studied. It is shown that water-sorption processes in magnesium aluminate ceramics leads to corresponding increase in positron trapping rates of extended defects located near intergranual boundaries. This catalytic affect has reversible nature, being strongly dependent on sorption water fluxes in ceramics. The fixation of all water-dependent positron trapping inputs allow to refine the most significant changes in positron trapping rate of extended defects.

  2. Ultrashort megaelectronvolt positron beam generation based on laser-accelerated electrons

    Science.gov (United States)

    Xu, Tongjun; Shen, Baifei; Xu, Jiancai; Li, Shun; Yu, Yong; Li, Jinfeng; Lu, Xiaoming; Wang, Cheng; Wang, Xinliang; Liang, Xiaoyan; Leng, Yuxin; Li, Ruxin; Xu, Zhizhan

    2016-03-01

    Experimental generation of ultrashort MeV positron beams with high intensity and high density using a compact laser-driven setup is reported. A high-density gas jet is employed experimentally to generate MeV electrons with high charge; thus, a charge-neutralized MeV positron beam with high density is obtained during laser-accelerated electrons irradiating high-Z solid targets. It is a novel electron-positron source for the study of laboratory astrophysics. Meanwhile, the MeV positron beam is pulsed with an ultrashort duration of tens of femtoseconds and has a high peak intensity of 7.8 × 1021 s-1, thus allows specific studies of fast kinetics in millimeter-thick materials with a high time resolution and exhibits potential for applications in positron annihilation spectroscopy.

  3. Electron-positron plasma generation in a pulsar magnetosphere

    International Nuclear Information System (INIS)

    Gurevich, A.V.; Istomin, Ya.N.

    1985-01-01

    The generation of an electron-positron plasma in vacuum (vacuum ''breakdown'') in the presence of an inhomogeneous electric field and strong curvilinear magnetic field is considered. A situation of this type may occur in the magnetosphere of a rotating neutron star. A general set of kinetic equations for electrons, positrons and γ quanta in a curvilinear magnetic field is derived by taking into account electron-positron pair production and emission of curvicur and synchrotron photons. The conditions for appearance of ''breakdown'' are determined and the threshold value of the elec tric field discontinuity at the surface of the star is found. Multiplication of particles in the magnetosphere is investigated and the electron, positron and γ quantum distribution functions are found. The extinction limit of pulsars is determined. The theory is shown to be in accordance with the observation results

  4. Concerning the trapping of positrons in ionic solids

    International Nuclear Information System (INIS)

    Kunz, A.B.; Waber, J.T.

    1982-01-01

    The total energy of several ionic crystals which contain lattice defects plus a positron were studied in the Hartree-Fock limit. Large uncontracted basis sets of GTO's were used to ensure binding if it would occur. Specifically, the attraction of a positron to a cation vacancy was sought for alkali halides as well as for nickel oxide. While the binding energy to nickel oxide was 8.1 eV, there was very little tendency for the positron to be trapped in the alkali halides. The trapping at a Vsub(k) site was also investigated using similar restricted HF approximation with large sets of GTO's. This defect in LiF was shown to be stable by 0.73 eV, by itself but was unable to bind a positron. These two results are not compatible with qPs being localized in such crystals. (Auth.)

  5. Study on energy and position resolution of MWPC for the Beijing e/π test beam

    International Nuclear Information System (INIS)

    Shen Ji; Chen Ziyu; Ye Yunxiu; Cui Xiangzong; Li Jiacai

    2006-01-01

    This paper describes the research on the energy and position resolution of the MWPC used in the e/π Test Beam on BEPC (Beijing Electron Positron Collider), which localizes the particles of e/π by the readout method of gravity center of the induced charges on the cathode strips. The spatial resolution of about 0.24 mm and energy resolution of 17% for 5.9 keV γ photons are attained at the 3700 V anode voltage. For the 1.1 GeV electrons, the spatial resolution of 0.3 mm is obtained. The contributions of various factors to energy resolution are analysed. It is found that energy resolution is changed with the anode voltage and there exists a least energy resolution. The reasons for these are discussed. (authors)

  6. Positron diffusion in zinc-blende-type semiconductors

    International Nuclear Information System (INIS)

    Singh, R.P.; Singh, M.

    1992-01-01

    A theory of positron diffusion in the presence of positron scattering with acoustic, piezoelectric-acoustic, and optical phonons in zinc-blende-type semiconductors is developed. The velocity-velocity correlation function is used to calculate the diffusion coefficient and the Green's function is used to calculate the correlation function. In this formulation the relaxation time automatically appears through the imaginary part of the self-energy. The effect of screening is included within the Thomas-Fermi approximation. The theory is used to calculate the energy relaxation time and diffusion length of positrons in GaAs. It is shown that the transverse and longitudinal phonons contribute almost the same amount towards the relaxation time in the piezoelectric-acoustic-phonon scattering of positrons. It is also found that the contribution of piezoelectric-acoustic-phonon scattering is about 10% to that of acoustic-phonon scattering at low temperatures. We obtained a fairly good agreement between our theory and experimental results available to us. It is found that optical-phonon scattering plays an important role in getting good agreement between theory and experiment at high temperatures

  7. Electrostatic solitons in unmagnetized hot electron-positron-ion plasmas

    International Nuclear Information System (INIS)

    Mahmood, S.; Ur-Rehman, H.

    2009-01-01

    Linear and nonlinear electrostatic waves in unmagnetized electron-positron-ion (e-p-i) plasmas are studied. The electrons and positrons are assumed to be isothermal and dynamic while ions are considered to be stationary to neutralize the plasma background only. It is found that both upper (fast) and lower (slow) Langmuir waves can propagates in such a type of pair (e-p) plasma in the presence of ions. The small amplitude electrostatic Korteweg-de Vries (KdV) solitons are also obtained using reductive perturbation method. The electrostatic potential hump structures are found to exist when the temperature of the electrons is larger than the positrons, while the electrostatic potential dips are obtained in the reverse temperature conditions for electrons and positrons in e-p-i plasmas. The numerical results are also shown for illustration. The effects of different ion concentration and temperature ratios of electrons and positrons, on the formation of nonlinear electrostatic potential structures in e-p-i plasmas are also discussed.

  8. Modeling of positron states and annihilation in solids

    International Nuclear Information System (INIS)

    Puska, M.J.

    2003-01-01

    Theoretical models and computational aspects to describe positron states and to predict positron annihilation characteristics in solids are discussed. The comparison of the calculated positron lifetimes, core annihilation lineshapes, and two-dimensional angular correlation maps with experimental results are used in identifying the structure (including the chemical composition) of vacancy-type defects and their development e.g. during thermal annealing. The basis of the modeling is the two-component density-functional theory. The ensuing approximations and the state-of-the-art electronic-structure computation methods enable practical schemes with a quantitative predicting power. (author)

  9. A fully automated and scalable timing probe-based method for time alignment of the LabPET II scanners

    Science.gov (United States)

    Samson, Arnaud; Thibaudeau, Christian; Bouchard, Jonathan; Gaudin, Émilie; Paulin, Caroline; Lecomte, Roger; Fontaine, Réjean

    2018-05-01

    A fully automated time alignment method based on a positron timing probe was developed to correct the channel-to-channel coincidence time dispersion of the LabPET II avalanche photodiode-based positron emission tomography (PET) scanners. The timing probe was designed to directly detect positrons and generate an absolute time reference. The probe-to-channel coincidences are recorded and processed using firmware embedded in the scanner hardware to compute the time differences between detector channels. The time corrections are then applied in real-time to each event in every channel during PET data acquisition to align all coincidence time spectra, thus enhancing the scanner time resolution. When applied to the mouse version of the LabPET II scanner, the calibration of 6 144 channels was performed in less than 15 min and showed a 47% improvement on the overall time resolution of the scanner, decreasing from 7 ns to 3.7 ns full width at half maximum (FWHM).

  10. Synthesis of positron labeled photoactive compounds: 18F labeled aryl azides for positron labeling of biochemical molecules

    International Nuclear Information System (INIS)

    Hashizume, Kazunari; Hashimoto, Naota; Miyake, Yoshihiro

    1995-01-01

    The authors have prepared various [ 18 F] fluorine labeled aryl azides as a novel photoactive compounds suitable for positron labeling of biochemical molecules. The introduction of fluorine substituents to aryl azides can be expected to have dramatic effects on their nature and reactivity toward photolysis. Positron labeled reagents for labeling proteins or peptides have recently attracted considerable attention due to their wide applicability in biochemistry and positron emission tomography (PET). Various labeled azide compounds are often used in biochemistry for radiolabeling biological molecules by photolysis, but there have been no reports on the preparation or use of fluorine-18 labeled azides. The authors now report a novel synthesis of 18 F-labeled aryl azides which will have wide application in the biochemistry and nuclear medicine as a means for 18 F-fluorine labeling for proteins, peptides, and nucleic acids. 2 tabs

  11. Automation of low temperature positron annihilation spectroscopy system

    International Nuclear Information System (INIS)

    Chaturvedi, T.P.; Venkiteswaran, S.; Pujari, P.K.

    1997-01-01

    This paper describes the automation implemented in the low temperature measurements in positron annihilation spectroscopic studies. This has not only widened the scope of the positron research, but also helps achieve result with better precision. (author). 3 refs., 1 fig

  12. Electron-Positron Accumulator (EPA)

    CERN Multimedia

    Photographic Service

    1986-01-01

    After acceleration in the low-current linac LIL-W, the electrons and positrons are accumulated in EPA to obtain a sufficient intensity and a suitable time-structure, before being passed on to the PS for further acceleration to 3.5 GeV. Electrons circulate from right to left, positrons in the other direction. Dipole bending magnets are red, focusing quadrupoles blue, sextupoles for chromaticity-control orange. The vertical tube at the left of the picture belongs to an optical transport system carrying the synchrotron radiation to detectors for beam size measurement. Construction of EPA was completed in spring 1986. LIL-W and EPA were conceived for an energy of 600 MeV, but operation was limited to 500 MeV.

  13. Positron emission tomography camera

    International Nuclear Information System (INIS)

    Anon.

    1986-01-01

    A positron emission tomography camera having a plurality of detector rings positioned side-by-side or offset by one-half of the detector cross section around a patient area to detect radiation therefrom. Each ring contains a plurality of scintillation detectors which are positioned around an inner circumference with a septum ring extending inwardly from the inner circumference along each outer edge of each ring. An additional septum ring is positioned in the middle of each ring of detectors and parallel to the other septa rings, whereby the inward extent of all the septa rings may be reduced by one-half and the number of detectors required in each ring is reduced. The additional septa reduces the costs of the positron camera and improves its performance

  14. Low-cost positron computed tomography

    International Nuclear Information System (INIS)

    Ott, R.J.; Batty, V.; Bateman, T.E.; Clack, R.; Flower, M.A.; Leach, M.O.; Marsden, P.; Webb, S.; McCready, V.R.

    1986-01-01

    After briefly describing the technique of positron emission tomography (PET) and the types of detectors used, the operational experience of a recently developed multi-wire proportional chamber positron camera which can be used to provide images using radionuclides such as 68 Ga, 124 I, 82 Rb, 55 Co, 18 F and 11 C is discussed. Clinical applications included PET imaging of the thyroid and the brain and possible future applications include PET imaging of the liver and tumour localization using antigen-specific monoclonal antibodies. Future developments to improve the sensitivity and spatial resolution of the detectors used in PET are discussed. (U.K.)

  15. An adiabatic matching device for the Orsay linear positron accelerator

    International Nuclear Information System (INIS)

    Chehab, R.; Le Meur, G.; Mouton, B.; Renard, M.

    1983-03-01

    An adiabatically tapered solenoidal magnetic field is used to match positron beam source emittance to accelerating section acceptance. Such a matching system improves the accepted energy band which has been accurately computed and compared with analytical determination. The tapered field is provided by stacked pancakes and solenoids of various radii; total lens length is about 0.75m. The adiabatic matching system took place of a quarter wave transformer system and has been in operation for two years. Positron conversion ratio is 3.3% for a 1 GeV incident beam and presents a factor of nearly two of improvement for the positron yield. Energy bandwidth of positron beam has also been increased by a factor of nearly 2.5; the output positron beam energy is of 1.2 GeV

  16. First image from a combined positron emission tomography and field-cycled MRI system.

    Science.gov (United States)

    Bindseil, Geron A; Gilbert, Kyle M; Scholl, Timothy J; Handler, William B; Chronik, Blaine A

    2011-07-01

    Combining positron emission tomography and MRI modalities typically requires using either conventional MRI with a MR-compatible positron emission tomography system or a modified MR system with conventional positron emission tomography. A feature of field-cycled MRI is that all magnetic fields can be turned off rapidly, enabling the use of conventional positron emission tomography detectors based on photomultiplier tubes. In this demonstration, two photomultiplier tube-based positron emission tomography detectors were integrated with a field-cycled MRI system (0.3 T/4 MHz) by placing them into a 9-cm axial gap. A positron emission tomography-MRI phantom consisting of a triangular arrangement of positron-emitting point sources embedded in an onion was imaged in a repeating interleaved sequence of ∼1 sec MRI then 1 sec positron emission tomography. The first multimodality images from the combined positron emission tomography and field-cycled MRI system show no additional artifacts due to interaction between the systems and demonstrate the potential of this approach to combining positron emission tomography and MRI. Copyright © 2010 Wiley-Liss, Inc.

  17. CO sub 2 absorption of perovskites as seen by positron lifetime spectroscopy

    CERN Document Server

    Suevegh, K; Juhasz, G; Homonnay, Z; Vertes, A

    2000-01-01

    The CO sub 2 absorption of several ABO sub 3 type perovskites was studied by positron lifetime spectroscopy. The longer positron lifetime was associated with positrons trapped by A site vacancies. The evaluated positron lifetime data indicated the relative stability of the crystal structure of Sr(Co sub 0 sub . sub 5 Fe sub 0 sub . sub 5)O sub 3 sub - subdelta against Ca doping at low Ca concentrations. Oxygen desorption and CO sub 2 absorption/desorption could also be followed by positron lifetime spectroscopy. It was shown that the concentration of oxygen vacancies has a large effect on positron lifetime data through the electron density of A site vacancies.

  18. Application of positron annihilation techniques in non-destructive testing

    International Nuclear Information System (INIS)

    Zeng Hui; Chen Zhiqiang; Jiang Jing; Xue Xudong; Wu Yichu; Liang Jianping; Liu Xiangbing; Wang Rongshan

    2014-01-01

    Background: The investigation of the material damage state is very important for industrial application. Most mechanical damage starts with a change in the microstructure of the material. Positron annihilation techniques are very sensitive probes for detecting defects and damage on an atomic scale in materials, which are of great concern in the engineering applications. Additionally they are apparatus of non-destruction, high-sensitivity and easy-use. Purpose: Our goal is to develop a system to exploit new non-destructive testing (NDT) methods using positron annihilation spectroscopy, a powerful tool to detect vacancy-type defects and their chemical environment. Methods: A positron NDT system was designed and constructed by modifying the 'sandwich structure' of sample-source-sample in conventional Doppler broadening and positron lifetime spectrometers. Doppler broadening and positron lifetime spectra of a single sample can be measured and analyzed by subtracting the contribution of a reference sample. Results: The feasibility and reliability of positron NDT system have been tested by analyzing nondestructively deformation and damage caused by mechanical treatment or by irradiation of metal alloys. This system can be used for detecting defects and damage in thick or large-size samples, as well as for measuring the two-dimension distribution of defects in portable, sensitive, fast way. Conclusion: Positron NDT measurement shows changes in real atomic-scale defects prior to changes in the mechanical properties, which are detectable by other methods of NDT, such as ultrasonic testing and eddy current testing. This system can be developed for use in both the laboratory and field in the future. (authors)

  19. Beam Collimation Studies for the ILC Positron Source

    Energy Technology Data Exchange (ETDEWEB)

    Drozhdin, A.; /Fermilab; Nosochkov, Y.; Zhou, F.; /SLAC

    2008-06-26

    Results of the collimation studies for the ILC positron source beam line are presented. The calculations of primary positron beam loss are done using the ELEGANT code. The secondary positron and electron beam loss, the synchrotron radiation along the beam line and the bremsstrahlung radiation in the collimators are simulated using the STRUCT code. The first part of the collimation system, located right after the positron source target (0.125 GeV), is used for protection of the RF Linac sections from heating and radiation. The second part of the system is used for final collimation before the beam injection into the Damping Ring at 5 GeV. The calculated power loss in the collimation region is within 100 W/m, with the loss in the collimators of 0.2-5 kW. The beam transfer efficiency from the target to the Damping Ring is 13.5%.

  20. New parameter-free polarization potentials in low-energy positron collisions

    Science.gov (United States)

    Jain, Ashok

    1990-01-01

    The polarization potential plays a decisive role in shaping up the cross sections in low energy positron collisions with atoms and molecules. However, its inclusion without involving any adjustable parameter, is still a challenge. Various other techniques employed so far for positron collisions are summarized, and a new, nonadjustable and very simple form of the polarization potential for positron-atom (molecule) collisions below the threshold of positronium formation is discussed. This new recently proposed potential is based on the correlation energy of a single positron in a homogeneous electron gas. The correlation energy was calculated by solving the Schrodinger equation of the positron-electron system and fitted to an analytical form in various ranges of the density parameter. In the outside region, the correlation energy is joined smoothly with the correct asymptotic form. This new positron correlation polarization (PCOP) potential was tested on several atomic and molecular targets such as the Ar, CO, and CH4. The results on the total and differential cross sections on these targets are shown along with the experimental data where available.

  1. First on-line positron experiments en route to pair-plasma creation

    Energy Technology Data Exchange (ETDEWEB)

    Stanja, Juliane; Hergenhahn, Uwe; Stenson, Eve V. [Max-Planck-Institut fuer Plasmaphysik (Germany); Niemann, Holger; Sunn Pedersen, Thomas [Max-Planck-Institut fuer Plasmaphysik (Germany); Ernst-Moritz-Arndt Universitaet Greifswald (Germany); Saitoh, Haruhiko [Max-Planck-Institut fuer Plasmaphysik (Germany); The University of Tokyo (Japan); Stoneking, Matthew R. [Lawrence University (United States); Hugenschmidt, Christoph; Piochacz, Christian [Technische Universitaet Muenchen (Germany); Schweikhard, Lutz [Ernst-Moritz-Arndt Universitaet Greifswald (Germany)

    2016-07-01

    Electron-positron plasmas are predicted to show a fundamentally different behavior from traditional ion-electron plasmas, because of the equal masses of the two species. Using up to 10{sup 9} positrons per second provided by the NEPOMUC (Neutron-Induced Positron Source Munich) facility, the APEX/PAX team aims to create the first such plasma confined in a toroidal magnetic trap. Positron beam parameters as well as efficient injection and confinement schemes for both species in toroidal geometries are fundamental to the project. In this contribution we present results from first on-line positron experiments. Besides characterizing the NEPOMUC beam we conducted positron injection experiments into a dipole magnetic field configuration. Using static electric fields, a 5-eV positron beam was transported across magnetic field lines into the confinement region. With this method, up to 38% of the incoming particles reach the confinement region and make at least a 180 revolution around the magnet. Under dedicated experimental conditions confinement on the order of 1 ms was realized.

  2. Positron emitters for in vivo plant research

    International Nuclear Information System (INIS)

    Fares, Y.; Goeschl, J.D.; Emran, A.M.; Drew, M.C.; McKinney, C.E.; Musser, R.L.; Strain, B.R.; Jaeger, C.H.

    1993-01-01

    Adopting a systems approach in analysis of the behavior of a biological system is a prime importance because all factors are considered simultaneously. Feedback is an important phenomenon occurring in dynamic biological systems, enabling appropriate regulatory and control functions to be maintained. In plants, the question whether photosynthesis or translocation controls carbon partitioning and hence productivity is of great agronomic importance, because many efforts are directed at selecting plant varieties with high rates of photosynthesis via genetic engineering and/or selective breeding. By use of short-lived positron emitting isotopes, such as C-11 and N-13, coupled with time-dependent and steady-state compartmental kinetic models, such dynamic biophysical plant problems are being unravelled. Questions such as: (i) source-sink complexities, (ii) experimental tests of the Munich-Horwitz theory of phloem transport (iii) uptake, transport and kinetics of nitrate and ammonium ions, and (iv) effects of ecological factors on growth rates were answered

  3. Study of four-lepton final states in electron-positron interactions at 29 GeV

    International Nuclear Information System (INIS)

    Petradza, A.

    1989-08-01

    This thesis presents a study of electron-positron scattering to four light leptons. The motivations behind it are twofold. Firstly, the study is a test of the theory of electron-positron interactions to 4th order in the fine structure constant α. A deviation from the theory could indicate the existence of a heavy new particle. Secondly, a measurement of these processes may prove useful in the understanding of other QED-type reactions. The method for simulating the four-lepton processes by the Monte Carlo event generator of Berends, Daverveldt and Kleiss is described. Theoretical predictions are compared to data from the Mark II and HRS experiments at the PEP storage ring. The observed events consist of four leptons at large angles. Data for all three e + e - e + e - , e + e - μ + μ - and μ + μ - μ + μ - processes are well described by the QED Monte Carlo calculation. The various kinematical distributions are in good agreement with QED to order α 4 . 18 refs., 64 figs., 19 tabs

  4. Manipulation of positron orbits in a dipole magnetic field with fluctuating electric fields

    Science.gov (United States)

    Saitoh, H.; Horn-Stanja, J.; Nißl, S.; Stenson, E. V.; Hergenhahn, U.; Pedersen, T. Sunn; Singer, M.; Dickmann, M.; Hugenschmidt, C.; Stoneking, M. R.; Danielson, J. R.; Surko, C. M.

    2018-01-01

    We report the manipulation of positron orbits in a toroidal dipole magnetic field configuration realized with electric fields generated by segmented electrodes. When the toroidal circulation motion of positrons in the dipole field is coupled with time-varying electric fields generated by azimuthally segmented outer electrodes, positrons undergo oscillations of their radial positions. This enables quick manipulation of the spatial profiles of positrons in a dipole field trap by choosing appropriate frequency, amplitude, phase, and gating time of the electric fields. According to numerical orbit analysis, we applied these electric fields to positrons injected from the NEPOMUC slow positron facility into a prototype dipole field trap experiment with a permanent magnet. Measurements with annihilation γ-rays clearly demonstrated the efficient compression effects of positrons into the strong magnetic field region of the dipole field configuration. This positron manipulation technique can be used as one of essential tools for future experiments on the formation of electron-positron plasmas.

  5. Electron and Positron Stopping Powers of Materials

    Science.gov (United States)

    SRD 7 NIST Electron and Positron Stopping Powers of Materials (PC database for purchase)   The EPSTAR database provides rapid calculations of stopping powers (collisional, radiative, and total), CSDA ranges, radiation yields and density effect corrections for incident electrons or positrons with kinetic energies from 1 keV to 10 GeV, and for any chemically defined target material.

  6. New positron annihilation spectroscopy techniques for thick materials

    International Nuclear Information System (INIS)

    Selim, F.A.; Wells, D.P.; Harmon, J.F.; Kwofie, J.; Erikson, G.; Roney, T.

    2003-01-01

    The Idaho Accelerator Center (IAC) has developed new techniques for positron annihilation spectroscopy (PAS) by using highly penetrating γ-rays to create positrons inside the material via pair production. Two sources of γ-rays have been employed. Bremsstrahlung beams from small-electron linacs (6 MeV) were used to generate positrons inside the material to perform Doppler-broadening spectroscopy. A 2 MeV proton beam was used to obtain coincident γ-rays from 27 Al target and enable lifetime and Doppler-broadening spectroscopy. This technique successfully measured stress/strain in thick samples, and showed promise to extend PAS into a variety of applications

  7. Electron-positron pair creation in heavy ion collisions

    International Nuclear Information System (INIS)

    Kienle, P.

    1987-01-01

    The authors review the status of experiments to study the electron positron pair creation in heavy ion atom collisions at bombarding energies close to the Coulomb barrier. The disentanglement and characterization of various sources of positrons observed in such collisions are described with a focus on the monoenergetic electron positron pairs observed. They seem to originate from the two-body decay of a family of neutral particles with masses of about 3m and lifetimes in the range of 6 x 10 - 14 s, produced by high Coulomb fields. First attempts were made to create these particles by resonant Bhabha scattering

  8. Near-Threshold Ionization of Argon by Positron Impact

    Science.gov (United States)

    Babij, T. J.; Machacek, J. R.; Murtagh, D. J.; Buckman, S. J.; Sullivan, J. P.

    2018-03-01

    The direct single-ionization cross section for Ar by positron impact has been measured in the region above the first ionization threshold. These measurements are compared to semiclassical calculations which give rise to a power law variation of the cross section in the threshold region. The experimental results appear to be in disagreement with extensions to the Wannier theory applied to positron impact ionization, with a smaller exponent than that calculated by most previous works. In fact, in this work, we see no difference in threshold behavior between the positron and electron cases. Possible reasons for this discrepancy are discussed.

  9. Positron annihilation lifetime spectroscopy study of Kapton thin foils

    Science.gov (United States)

    Kanda, G. S.; Ravelli, L.; Löwe, B.; Egger, W.; Keeble, D. J.

    2016-01-01

    Variable energy positron annihilation lifetime spectroscopy (VE-PALS) experiments on polyimide material Kapton are reported. Thin Kapton foils are widely used in a variety of mechanical, electronic applications. PALS provides a sensitive probe of vacancy-related defects in a wide range of materials, including open volume in polymers. Varying the positron implantation energy enables direct measurement of thin foils. Thin Kapton foils are also commonly used to enclose the positron source material in conventional PALS measurements performed with unmoderated radionuclide sources. The results of depth-profiled positron lifetime measurements on 7.6 μm and 25 μm Kapton foils are reported and determine a dominant 385(1) ps lifetime component. The absence of significant nanosecond lifetime component due to positronium formation is confirmed.

  10. Thermal equilibrium defects in anthracene probed by positron annihilation

    International Nuclear Information System (INIS)

    Uedono, Akira; Tanigawa, Shoichiro; Tachibana, Masaru; Shimizu, Mikio; Satoh, Masaaki; Kojima, Kenichi; Ishibashi, Shoji; Kawano, Takao.

    1996-01-01

    Defects in anthracene were investigated by the positron annihilation technique. Doppler broadening profiles of the annihilation radiation and lifetime spectra of positrons were measured in the temperature range between 305 K and 516 K. The lifetime of positrons annihilated from the delocalized state was determined to be 0.306 ns around room temperature. Below the melting point, the observed temperature dependence of the line shape parameter S was explained assuming the formation energy of thermal equilibrium defects was 1 eV. Above the melting point, the pick-off annihilation of ortho-positronium in open spaces was observed, where the size of these spaces was estimated to be 0.2 nm 3 . The annihilation of positrons from the self-trapped state was also discussed. (author)

  11. Thermal equilibrium defects in anthracene probed by positron annihilation

    Energy Technology Data Exchange (ETDEWEB)

    Uedono, Akira; Tanigawa, Shoichiro [Tsukuba Univ., Ibaraki (Japan). Inst. of Materials Science; Tachibana, Masaru; Shimizu, Mikio; Satoh, Masaaki; Kojima, Kenichi; Ishibashi, Shoji; Kawano, Takao

    1996-06-01

    Defects in anthracene were investigated by the positron annihilation technique. Doppler broadening profiles of the annihilation radiation and lifetime spectra of positrons were measured in the temperature range between 305 K and 516 K. The lifetime of positrons annihilated from the delocalized state was determined to be 0.306 ns around room temperature. Below the melting point, the observed temperature dependence of the line shape parameter S was explained assuming the formation energy of thermal equilibrium defects was 1 eV. Above the melting point, the pick-off annihilation of ortho-positronium in open spaces was observed, where the size of these spaces was estimated to be 0.2 nm{sup 3}. The annihilation of positrons from the self-trapped state was also discussed. (author)

  12. Physical and technical basis of positron emission tomography (PET)

    International Nuclear Information System (INIS)

    Bauer, R.

    1994-01-01

    Positron emission tomography utilizes the annihilation of positrons, generating pairs of gamma quanta which are emitted in opposing directions. 'Electronic collimation' is performed by coincident detection of both quanta. Thus, there is no need for mechanical collimators and no limiting connection between sensitivity and spatial resolution. Transversal tomograms are reconstructed from the projection data by means of highly sophisticated data processing. The half life of the most positron emitters used in medical applications is short and of the order of some minutes. Therefore, many positron emitters have to be produced on-side by means of a cyclotron. PET is superior to SPECT with respect to physical and technical aspects, but the high costs of PET limit its wide-spread use up to now. (orig.) [de

  13. Positron Interactions with Atoms and Ions

    Science.gov (United States)

    Bhatia, Anand K.

    2012-01-01

    Dirac, in 1928, combining the ideas of quantum mechanics and the ideas of relativity invented the well-known relativistic wave equation. In his formulation, he predicted an antiparticle of the electron of spin n-bar/2. He thought that this particle must be a proton. Dirac published his interpretation in a paper 'A theory of electrons and protons.' It was shown later by the mathematician Hermann Weyl that the Dirac theory was completely symmetric between negative and positive particles and the positive particle must have the same mass as that of the electron. In his J. Robert Oppenheimer Memorial Prize Acceptance Speech, Dirac notes that 'Blackett was really the first person to obtain hard evidence for the existence of a positron but he was afraid to publish it. He wanted confirmation, he was really over cautious.' Positron, produced by the collision of cosmic rays in a cloud chamber, was detected experimentally by Anderson in 1932. His paper was published in Physical Review in 1933. The concept of the positron and its detection were the important discoveries of the 20th century. I have tried to discuss various processes involving interactions of positrons with atoms and ions. This includes scattering, bound states and resonances. It has not been possible to include the enormous work which has been carried out during the last 40 or 50 years in theory and measurements.

  14. Positron Spectroscopy of Nanodiamonds after Hydrogen Sorption

    Directory of Open Access Journals (Sweden)

    Lyudmila Nikitina

    2018-01-01

    Full Text Available The structure and defects of nanodiamonds influence the hydrogen sorption capacity. Positronium can be used as a sensor for detecting places with the most efficient capture of hydrogen atoms. Hydrogenation of carbon materials was performed from gas atmosphere. The concentration of hydrogen absorbed by the sample depends on the temperature and pressure. The concentration 1.2 wt % is achieved at the temperature of 243 K and the pressure of 0.6 MPa. The hydrogen saturation of nanodiamonds changes the positron lifetime. Increase of sorption cycle numbers effects the positron lifetime, as well as the parameters of the Doppler broadening of annihilation line. The electron-positron annihilation being a sensitive method, it allows detecting the electron density fluctuation of the carbon material after hydrogen saturation.

  15. Prospects for the creation of positron-electron plasmas in a non-neutral stellarator

    International Nuclear Information System (INIS)

    Pedersen, T Sunn; Boozer, A H; Dorland, W; Kremer, J P; Schmitt, R

    2003-01-01

    The prospects of creating positron-electron plasmas confined in a stellarator are discussed. A pure electron plasma would be created before the positrons are introduced, to facilitate efficient injection and a long confinement time of the positrons. Gyrokinetic simulations are presented suggesting that a positron-electron plasma may be stable to low-frequency microturbulence if operated well below the Brillouin limit, and transport may be neoclassical. If this is the case, significant positron-electron plasma densities can be reached with positron sources that exist today

  16. Applications of positron annihilation spectroscopy to polymeric and biological systems

    International Nuclear Information System (INIS)

    Jean, Y.C.; Chen, Hongmin; Liu, Guang; Chakka, Lakshmi; Gadzia, Joseph E.

    2007-01-01

    Positron annihilation spectroscopy (PAS) is a novel radio-analytical technique which uses the positron (anti-electron) and is capable of probing the atomic and molecular scale (0.2-2 nm) free-volume and hole properties in polymeric and biological materials. Recently, we developed positron annihilation lifetime and Doppler broadening of energy spectroscopies coupled with a variable mono-energetic positron beam to measure the free-volume depth profile from the surface, interfaces, and to the bulk. This paper presents applications of PAS to determine multi-layer structures, glass transition temperatures in nano-scale polymeric films and to detect cancer in the human skin. (author)

  17. Positron emission tomography

    International Nuclear Information System (INIS)

    Pavuk, M.

    2003-12-01

    The aim of this project is to provide a simple summary of new trends in positron emission tomography and its basic physical principles. It provides thereby compendious introduction of the trends of the present development in diagnostics using PET systems. A review of available literature was performed. (author)

  18. Positron emission tomography: a new paradigm in cancer management

    International Nuclear Information System (INIS)

    Paez Gutierrez, Diana Isabel; De los Reyes, Amelia; Llamas Olier, Augusto

    2007-01-01

    The National Cancer Institute (NCI) is currently building a positron emission tomography facility that will house a cyclotron and a PET fusion scanner. lt should be operational as of december 2007, being a cancer dedicated national referral center, the NCI should provide both positron-emitting radiopharmaceuticals and medical services to institutions and patients nationwide. PET technology provides metabolic information that has been documented to be useful in patient care. The properties of positron decay allow accurate imaging of the in vivo distribution of positron-emitting radiopharmaceuticals. a wide array of positron-emitting radiopharmaceuticals has been used to characterize multiple physiologic and pathologic states. The major clinical PET applications are in cancer patients using fluorine-18 fluorodeoxyglucose (FDG). FDG, an analogue of glucose, accumulates in most tumors in a greater amount than it does in normal tissue. PET is being used in diagnosis and follow-up of several malignancies, and the list of articles supporting its use continues to grow. in this article, the instrumentation aspects of PET are described and most of the clinical applications in oncology are described

  19. Positron annihilation lifetime study of oxide dispersion strengthened steels

    International Nuclear Information System (INIS)

    Krsjak, V.; Szaraz, Z.; Hähner, P.

    2012-01-01

    A comparative positron annihilation lifetime study has been performed on various commercial ferritic and ferritic/martensitic oxide dispersion strengthened (ODS) steels. Both as-extruded and recrystallized materials were investigated. In the materials with recrystallized coarse-grained microstructures, only the positron trapping at small vacancy clusters and yttria nanofeatures was observed. Materials which had not undergone recrystallization treatment clearly showed additional positron trapping which is associated with dislocations. Dislocation densities were calculated from a two-component decomposition of the positron lifetime spectra by assuming the first component to be a superposition of the bulk controlled annihilation rate and the dislocation controlled trapping rate. The second component (which translates into lifetimes of 240–260 ps) was found to be well separated in all those ODS materials. This paper presents the potentialities and limitations of the positron annihilation lifetime spectroscopy, and discusses the results of the experimental determination of the defect concentrations and sensitivity of this technique to the material degradation due to thermally induced precipitation of chromium-rich α′ phases.

  20. Studies of glasses by positron annihilation

    International Nuclear Information System (INIS)

    Brauer, G.; Boden, G.

    1981-04-01

    Investigations of silica glasses, pyrocerams and metallic glasses by positron annihilation (lifetime, Doppler broadening) are presented. The measurements on silica glasses showed, that silica glass fused from naturally occuring quartz exhibits a higher order than that one produced from SiCl 4 . Furthermore it was found that the order of silica glasses increases after heat treatment above 900 0 C. Thus the X-amorphous state of silica glasses could be characterized by positron annihilation what is impossible at present by diffraction methods. (author)

  1. Generation of slow positron beam and beam bunching

    International Nuclear Information System (INIS)

    Azuma, O.; Satoh, T.; Shitoh, M.; Kaneko, N.; Kawaratani, T.; Hara, O.

    1994-01-01

    Two items are described in this report. One is about the outline of our slow positron beam system, which has been fabricated as a commercial prototype. The other is about the calculation result of positron beam bunching, which will be an additional function to the system. (author)

  2. PEP-II status report

    International Nuclear Information System (INIS)

    Dorfan, J.M.

    1998-06-01

    The main design features of the PEP-II asymmetric two-ring electron-positron B Factory collider, built at the Stanford Linear Accelerator Center, are described. This facility will complete construction in June 1998. The high energy ring, completed in May 1997, has had 3 months of commissioning and successfully stored 0.75 A of electrons. The success of the high energy ring testing validates not only its ring components, but also the injection system, the RF system and the control system all of which are common to the two rings

  3. Description of the intense, low energy, monoenergetic positron beam at Brookhaven

    International Nuclear Information System (INIS)

    Lynn, K.G.; Mills, A.P. Jr.; Roellig, L.O.; Weber, M.

    1985-01-01

    An intense (4 x 10 7 s -1 ), low energy (approx. =1.0 eV), monoenergetic (ΔE approx. = 75 MeV) beam of positrons has been built at the Brookhaven National Laboratory. This flux is more than 10 times greater than any existing beam from radioactive sources. Plans are underway to increase further the flux by more than an order of magnitude. The intense low energy positron beam is made by utilizing the High Flux Beam Reactor at Brookhaven to produce the isotope 64 Cu with an activity of 40 curies of positrons. Source moderation techniques are utilized to produce the low energy positron beam from the high energy positrons emitted from 64 Cu. 31 refs., 7 figs

  4. Positron production using a 1.7 MV pelletron accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Alcantara, K. F.; Santos, A. C. F. [Instituto de Fisica, Universidade Federal do Rio de Janeiro, Caixa Postal 68528, Rio de Janeiro, RJ 21941-972 (Brazil); Crivelli, P. [Institute for Particle Physics, ETH Zurich (Switzerland)

    2013-04-19

    We report the foremost phase of a fourth generation positron source, being constructed at the Federal University of Rio de Janeiro. Positron yields are reported by making use of the {sup 19}F(p,{alpha}e{sup +}e{sup -}){sup 16}O reaction, where the fluorine target is in the form of a CaF{sub 2} pellet. Positron production has been observed by detecting 511 keV annihilation gamma rays emerging from the irradiated CaF{sub 2} target.

  5. Ion-irradiated polymer studied by a slow positron beam

    International Nuclear Information System (INIS)

    Kobayashi, Yoshinori; Kojima, Isao; Hishita, Shunichi; Suzuki, Takenori.

    1995-01-01

    Poly (aryl-ether-ether ketone) (PEEK) films were irradiated with 1MeV and 2MeV 0 + ions and the positron annihilation Doppler broadening was measured as a function of the positron energy. The annihilation lines recorded at relatively low positron energies were found to become broader with increasing the irradiation dose, suggesting that positronium (Ps) formation may be inhibited in the damaged regions. A correlation was observed between the Doppler broadening and spin densities determined by electron spin resonance (ESR). (author)

  6. Positron Annihilation Study of Radiation Defects in Zinc Oxide

    OpenAIRE

    Tomiyama, Noriyuki; Takenaka, Minoru; Kuramoto, Eiichi

    1992-01-01

    Positron annihilation studies have been carried out to clarify the radiation induced defects in ZnO single crystals. Vapor-grown ZnO crystals were irradiated at 77 K with 28 MeV electrons. Before irradiation as-grown specimens showed the mean positron lifetime in the range of 160-195 ps. Electron irradiation increased the mean positron lifetime up to 205-210 ps.This long-lifetime disappeared until 473 K during successive isochronal annealing steps. The radiation-induced coloration was anneale...

  7. Positron annihilation studies in lysozyme and catalase

    International Nuclear Information System (INIS)

    Rohilla, Y.; Singh, K.P.; Roy Choudhury, S.; Jain, P.C.

    1992-01-01

    Positron annihilation studies have been carried out in two enzymes, lysozyme and catalase. Temperature dependence of the positron lifetimes in these two enzymes has been investigated. The results explained in terms of the free volume model and fluctuations between different conformational micro states of enzyme structures provide a new insight into the mechanism of bio-activity of these enzymes. (author). 15 refs., 4 figs

  8. Applications of positron annihilation spectroscopy in materials research

    Science.gov (United States)

    Singh, Jag J.

    1988-01-01

    Positron Annihilation Spectroscopy (PAS) has emerged as a powerful technique for research in condensed matter. It has been used extensively in the study of metals, ionic crystals, glasses and polymers. The present review concentrates on applications of positron lifetime measurements for elucidation of the physicochemical structure of polymers.

  9. Recent developments in positron emission tomography (PET) instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Derenzo, S.E.; Budinger, T.F.

    1986-04-01

    This paper presents recent detector developments and perspectives for positron emission tomography (PET) instrumentation used for medical research, as well as the physical processes in positron annihilation, photon scattering and detection, tomograph design considerations, and the potentials for new advances in detectors. 117 refs., 4 figs., 4 tabs.

  10. Recent developments in positron emission tomography (PET) instrumentation

    International Nuclear Information System (INIS)

    Derenzo, S.E.; Budinger, T.F.

    1986-04-01

    This paper presents recent detector developments and perspectives for positron emission tomography (PET) instrumentation used for medical research, as well as the physical processes in positron annihilation, photon scattering and detection, tomograph design considerations, and the potentials for new advances in detectors. 117 refs., 4 figs., 4 tabs

  11. The stationary non-equilibrium plasma of cosmic-ray electrons and positrons

    Science.gov (United States)

    Tomaschitz, Roman

    2016-06-01

    The statistical properties of the two-component plasma of cosmic-ray electrons and positrons measured by the AMS-02 experiment on the International Space Station and the HESS array of imaging atmospheric Cherenkov telescopes are analyzed. Stationary non-equilibrium distributions defining the relativistic electron-positron plasma are derived semi-empirically by performing spectral fits to the flux data and reconstructing the spectral number densities of the electronic and positronic components in phase space. These distributions are relativistic power-law densities with exponential cutoff, admitting an extensive entropy variable and converging to the Maxwell-Boltzmann or Fermi-Dirac distributions in the non-relativistic limit. Cosmic-ray electrons and positrons constitute a classical (low-density high-temperature) plasma due to the low fugacity in the quantized partition function. The positron fraction is assembled from the flux densities inferred from least-squares fits to the electron and positron spectra and is subjected to test by comparing with the AMS-02 flux ratio measured in the GeV interval. The calculated positron fraction extends to TeV energies, predicting a broad spectral peak at about 1 TeV followed by exponential decay.

  12. A random walk approach to the diffusion of positrons in gaseous media

    International Nuclear Information System (INIS)

    Girardi-Schappo, M.; Tenfen, W.; Arretche, F.

    2013-01-01

    In this work, we present a random walk model to study the positron diffusion in gaseous media. The positron-atom interaction is described through positron-target cross sections. The main idea is to obtain how much energy a positron transfer to the environment atoms, through ionizations and electronic excitations until its annihilation, taking the ratio between each energetically available collision channel to the total one as the probability for each process to occur. As a first application, we studied how the positron diffuse in gases of helium, neon, argon and their mixtures. To characterize the positron dynamics in each system, we calculated the radiation profile generated from the annihilation, their diffusion profiles and the most probable distances for excitation and ionization. (authors)

  13. Mark-II Data Acquisition and Trigger system

    International Nuclear Information System (INIS)

    Breidenbach, M.

    1984-06-01

    The Mark-II Data Acquisition and Trigger system requirements and general solution are described. The solution takes advantage of the synchronous crossing times and low event rates of an electron positron collider to permit a very highly multiplexed analog scheme to be effective. The system depends on a two level trigger to operate with acceptable dead time. The trigger, multiplexing, data reduction, calibration, and CAMAC systems are described

  14. Development of a Positron Source for JLab at the IAC

    Energy Technology Data Exchange (ETDEWEB)

    Forest, Tony [Idaho State Univ., Pocatello, ID (United States)

    2013-10-12

    We report on the research performed towards the development of a positron sour for Jefferson Lab's (JLab) Continuous Electron Beam Accelerator Facility (CEBAF) in Newport News, VA. The first year of work was used to benchmark the predictions of our current simulation with positron production efficiency measurements at the IAC. The second year used the benchmarked simulation to design a beam line configuration which optimized positron production efficiency while minimizing radioactive waste as well as design and construct a positron converter target. The final year quantified the performance of the positron source. This joint research and development project brought together the experiences of both electron accelerator facilities. Our intention is to use the project as a spring board towards developing a program of accelerator based research and education which will train students to meet the needs of both facilities as well as provide a pool of trained scientists.

  15. Development of a Slow Positron Facility at Hebrew University of Jerusalem

    Science.gov (United States)

    Kelleher, Aidan

    2013-03-01

    Positron annihilation spectroscopy provides both depth of penetration to study bulk defects in materials as well as nano-scale resolution. This measurement range is achieved by slowing positrons from a radioactive source, typically 22Na, by sending them through a moderator, typically W or solid Ne. The nearly thermal positrons are then accelerated to the desired energy by means of an electrostatic potential. The SPOT project at The Hebrew University of Jerusalem proposes to increase the luminosity of the beam by applying the best practices currently in us, as well as using a short-lived source of positrons, 18F. Simulations based on our current designs indicate this project will be able to deliver positrons in the energy range of 50-50000eV with an energy resolution of 1eV is possible. We will present the unique technical challenges of using this source of positrons, how we plan to overcome them, the results of simulations, and facility construction progress.

  16. The positron accumulator ring for the APS

    International Nuclear Information System (INIS)

    Crosbie, E.A.

    1989-01-01

    The Positron Accumulator Ring (PAR) is designed to accumulate and damp positrons from the 450-MeV linac during the 0.5-s cycle time of the injector synchrotron for the APS 7-GeV storage ring. During 0.4 s of each synchrotron cycle, up to 24 linac pulses are injected into the horizontal phase space of the PAR at a 60-Hz rate. Each injected pulse occupies about 1.3 of the circumference of the accumulator ring. After 0.1 s for longitudinal damping, the single accumulated bunch is transferred to one of the 353-MHz buckets of the injector synchrotron RF system. The bunch is accelerated to 7 GeV and transferred to the storage ring, while the PAR accumulates the next bunch of positrons. 2 refs., 3 figs., 2 tabs

  17. The positron accumulator ring for the APS

    International Nuclear Information System (INIS)

    Crosbie, E.A.

    1989-01-01

    The Positron Accumulator Ring (PAR) is designed to accumulate and damp positrons from the 450-MeV linac during the 0.5-s cycle time of the injector synchrotron for the APS 7-GeV storage ring. During 0.4 s of each synchrotron cycle, up to 24 linac pulses are injected into the horizontal phase space of the PAR at a 60-Hz rate. Each injected pulse occupies about 1/3 of the circumference of the accumulator ring. After 0.1 s for longitudinal damping, the single accumulated bunch is transferred to one of the 353-MHz buckets of the injector synchrotron RF system. The bunch is accelerated to 7 GeV and transferred to the storage ring, while the PAR accumulates the next bunch of positrons. 2 refs., 3 figs., 2 tabs

  18. Metastable self-trapping of positrons in MgO

    Science.gov (United States)

    Monge, M. A.; Pareja, R.; González, R.; Chen, Y.

    1997-01-01

    Low-temperature positron annihilation measurements have been performed on MgO single crystals containing either cation or anion vacancies. The temperature dependence of the S parameter is explained in terms of metastable self-trapped positrons which thermally hop through the crystal lattice. The experimental results are analyzed using a three-state trapping model assuming transitions from both delocalized and self-trapped states to deep trapped states at vacancies. The energy level of the self-trapped state was determined to be (62+/-5) meV above the delocalized state. The activation enthalpy for the hopping process of self-trapped positrons appears to depend on the kind of defect present in the crystals.

  19. Beijing: Green light for feasibility studies on tau-charm factory

    International Nuclear Information System (INIS)

    Anon.

    1995-01-01

    Full text: Since first collisions were achieved at the Beijing Institute of High Energy Physics BEPC electronpositron collider in October 1989, nine million J/psi and 1.4 million psi primes have been collected, as well as integrated luminosities of five and 23 inverse picobarns collected from respectively the tau threshold and a collision energy of 4.03 GeV. In addition, the BES spectrometer group has obtained several important tau results, including a precise measurement of the tau mass and precision studies of important tau decays. These results were a focus of interest at major meetings last summer. With many physicists across the world interested in the future of the BEPC/BES complex, in October, came the good news that the Chinese leadership had promised to support Beijing's feasibility study project for a Tau-Charm Factory (tauCF) on the BEPC site. BEPC's working energy, in the range 3 - 5.6 GeV, covers a high density region of resonances including charmonium, its excited states and production thresholds of many particles, such as the tau lepton pairs and charmed particles(mesons and baryons). The present experimental statistics and detection resolution at BEPC/ BES are not up to the task of testing the Standard Model to its limit and searching for new physics. The tauCF would be a logical continuation of BEPC/BES. With a hundred times greater luminosity and tenfold detection accuracy, tauCF could play a decisive role in ongoing physics goals. A SLAC (Stanford) workshop last summer on tauCF in the B-Factory Era underlined the importance of tauCF, with conclusion that a Bfactory cannot replace tauCF. Many scientists have observed that Beijing is one of the best places for a taucharm factory

  20. Applications of positron annihilation spectroscopy in materials research

    International Nuclear Information System (INIS)

    Singh, J.J.

    1988-01-01

    Positron Annihilation Spectroscopy (PAS) has emerged as a powerful technique for research in condensed matter. It has been used extensively in the study of metals, ionic crystals, glasses and polymers. The present review concentrates on applications of positron lifetime measurements for elucidation of the physicochemical structure of polymers. 10 references

  1. Positron Annihilation Ratio Spectroscopy (PsARS) Applied to Positronium Formation Studies

    Science.gov (United States)

    2010-03-01

    Positron Annihilation Ratio Spectroscopy (PsARS). These experimental techniques have been used for a variety of military and civilian applications ... POSITRON ANNIHILATION RATIO SPECTROSCOPY (PsARS) APPLIED TO POSITRONIUM FORMATION STUDIES THESIS...of Defense, or the United States Government. AFIT/GNE/ENP/10-M07 POSITRON ANNIHILATION RATIO SPECTROSCOPY

  2. Slow positrons in single-crystal samples of Al and Al-AlxOy

    Science.gov (United States)

    Lynn, K. G.; Lutz, H.

    1980-11-01

    Well-characterized Al(111) and Al(100) samples were studied with monoenergetic positrons before and after exposure to oxygen. Both positronium-formation and positron-emission curves were obtained for various incident positron energies at sample temperatures ranging from 160-900 K. The orthopositronium decay signal provides a unique signature that the positron has emerged from the surface region of a clean metal. In the clean Al crystals part of the positronium formed near the surface is found to be associated with a temperature-activated process described as the thermally activated detrapping of a positron from a surface state. A simple positron diffusion model, including surface and vacancy trapping, is fitted to the positronium data and an estimate of the binding energy of the positron in this trap is made. The positron diffusion constant is found to have a negative temperature dependence before the onset of positron trapping at thermally generated monovacancies (>500 K), in reasonable agreement with theoretical predictions. The depth of the positron surface state is reduced or positronium is formed in the chemisorbed layer as oxygen is adsorbed on both Al sample surfaces, thus increasing the positronium fraction and decreasing the positron emission. At higher oxygen exposures [>500 L (1 L = 10-6 torr sec)] positron or positronium traps are generated in the overlayer and the positronium fraction is reduced. The amorphous-to-crystalline surface transition of AlxOy on Al is observed between 650 and 800 K by the change in the positronium fraction and is interpreted as the removal of trapping centers in the metal-oxide overlayer. At the higher temperatures and incident energies vacancy trapping is observed by the decrease in the positron diffusion length in both the clean and the underlying Al of the oxygen-exposed samples. Similar vacancy formation enthalpies for Al are extracted in both the clean and oxygen-covered samples by a simple model and are in good

  3. Positron annihilation in superconducting 123 compounds

    International Nuclear Information System (INIS)

    Peter, M.; Manuel, A.A.; Erb, A.

    1998-01-01

    After a brief review of the theory of angular correlation of positron annihilation radiation (ACAR), the authors illustrate experimental principles and give examples of successful determination of electron momentum density (EMD) and of positron lifetime in solids. The central question which the authors try to answer concerns the contribution of positron spectroscopy to the knowledge and understanding of the new high temperature superconducting oxides. They find that in these oxides also, partially filled bands exist and they can observe parts of their Fermi surface and measure lifetimes in accordance with band theoretical calculations. There are characteristic differences, however. The intensity of the anisotropy of the ACAR signal is below theoretical expectation and signals depend on sample preparation. Recent studies by the Geneva group have concerned dependence of the signals on impurities, on oxygen content and on the thermal history of preparation. Of particular interest are correlations between the variations of these signals and between the variations of structural and transport properties in these substances. Besides deliberate additions of impurities, the Geneva group also reports progress in the preparations of samples of highest purity (barium zirconate crucibles). The alloy series Pr x Y 1-x Ba 2 Cu 3 O 7-δ is of special interest because of exceptional transport properties. The recent positron results on these materials will be presented and commented in the light of theoretical models and in the light of the reported superconductivity of the Pr-compound

  4. Positron annihilation spectroscopy in condensed matter

    International Nuclear Information System (INIS)

    Brauer, G.

    1982-09-01

    The topic of positron annihilation spectroscopy (PAS) is the investigation of all aspects connected with the annihilation of slow positrons. This work deals with the application of PAS to different problems of materials science. The first chapter is an introduction to fundamental aspects of positron annihilation, as far as they are important to the different experimental techniques of PAS. Chapter 2 is concerned with the information obtainable by PAS. The three main experimental techniques of PAS (2γ-angular correlation, positron lifetime and Doppler broadening) are explained and problems in the application of these methods are discussed. Chapter 3 contains experimental results. According to the different fields of application it was subgrouped into: 1. Investigations of crystalline solids. Detection of structural defects in Cu, estimation of defect concentrations, study of the sintering of Cu powders as well as lattice defects in V 3 Si. 2. Chemical investigations. Structure of mixed solvents, selective solvation of mixed solvents by electrolytes as well as the micellization of sodium dodecylsulphate in aqueous solutions. 3. Investigations of glasses. Influence of heat treatment and production technology on the preorder of X-amorphous silica glass as well as preliminary measurements of pyrocerams. 4. Investigations of metallic glasses. Demonstration of the influence of production technology on parameters measurable by PAS. Chapter 4 contains a summary as well as an outlook of further applications of PAS to surface physics, medicine, biology and astrophysics. (author)

  5. Positron emission tomography of the lung

    International Nuclear Information System (INIS)

    Wollmer, P.

    1984-01-01

    Positron emission tomography enables the distribution of positron emitting isotopes to be imaged in a transverse plane through the body and the regional concentration of the isotope to be measured quantitatively. This thesis reports some applications of positron emission tomography to studies of pulmonary pathophysiology. Measurements in lung phantoms showed that regional lung density could be measured from a transmission tomogram obtained with an external source of positron emitting isotope. The regional, fractional blood volume was measured after labelling the blood with carbon-11-monoxide. Regional extravascular lung density (lung tissue and interstitial water per unit thoracic volume) was obtained by subtracting fractional blood volume from lung density. Measurements in normal subjects revealed large regional variations in lung density and fractional blood volume in the supine posture. Extravascular lung density showed a more uniform distribution. The technique has been used to study patients with chronic interstitial pulmonary oedema, pulmonary sarcoidosis and fibrosis, pulmonary arterial hypertension and patients with intracardiac, left-to-right shunt. Tomographic measurements of pulmonary tissue concentration of radionuclides are difficult, since corrections for the blood content and the inflation of the lung must be applied. A simultaneous measurement of lung density and fractional blood volume allows such corrections to be made and the extravascular tracer concentration to be calculated. This has been applied to measurements of the tissue penetration of carbon-11-labelled erythromycin in patients with lobar pneumonia. (author)

  6. Radiation damage analysis by positron annihilation spectroscopy

    International Nuclear Information System (INIS)

    Siegel, R.W.

    1979-01-01

    The application of positron annihilation spectroscopy (PAS) to the characterization and study of defects in metals produced by radiation damage is discussed. The physical basis for the positron annihilation techniques (lifetime, Doppler broadening, angular correlation) is introduced and the techniques briefly described. Some examples of the application of PAS to radiation damage analysis are presented with a view toward elucidating the particular advantages of PAS over more traditional defect characterization techniques

  7. Anomalous positron emission in heavy ion-collisions

    International Nuclear Information System (INIS)

    Kienle, P.

    1986-09-01

    In section two we shortly present the experimental methods and first results on positron lines. Section three deals with the dependence of the positron line production on the charge of the collision system, bombarding energy and scattering angle. The results of the first e + -e - -coincidence studies are reviewed in section 4. In the last paragraph we make some remarks on future developments of the experimental methods. (orig./HSI)

  8. Metal/oxide/semiconductor interface investigated by monoenergetic positrons

    Science.gov (United States)

    Uedono, A.; Tanigawa, S.; Ohji, Y.

    1988-10-01

    Variable-energy positron-beam studies have been carried out for the first time on a metal/oxide/semiconductor (MOS) structure of polycrystalline Si/SiO 2/Si-substrate. We were successful in collecting injected positrons at the SiO 2/Si interface by the application of an electric field between the MOS electrodes.

  9. Positron beams: The journey from fundamental physics to industrial application

    International Nuclear Information System (INIS)

    Coleman, P.G.

    2002-01-01

    Monoenergetic beams of positrons developed for fundamental atomic physics experiments have evolved - via basic and applied research in condensed matter physics and chemistry - to a phase in which possibilities for commercial exploitation are becoming apparent. The evolution of positron beam technology, from table-top laboratory-based apparatus with positrons of energies controllable in the 10 0 -10 2 eV energy range and beam intensities of ∼1 s -1 , to systems capable of delivering positrons of energies from 0.02 eV to MeV at intensities as high as 10 8 s -1 , has been both steady and saltatory. The journey from fundamental research to industrial application is a classic example of scientific development; a brief summary of steps on the way is followed by an example in which an attempt is being made to harness the efficacy of positron beams applied to defect spectroscopy of semiconductor structures to create an instrument of value to the ion implantation industry

  10. Positron spectroscopy analysis of vacancy-solute nanoaggregates in Al-Cu

    International Nuclear Information System (INIS)

    Ferragut, R.; Ferro, G.; Biasini, M.; Dupasquier, A.; Somoza, A.

    2004-01-01

    This work addresses the process of ageing in Al-4wt.% Cu at two temperatures (150 C, 180 C) and in conditions of secondary ageing at temperatures up to 60 C, after artificial ageing treatment at 150 C, Positron lifetime and coincidence Doppler broadening measurements are reported. The analysis shows an initial association of positron trapping sites with Cu (about 9 at.% Cu at the annihilation site) that decreases to 7/6% in the initial stages of ageing, but then increases sharply (up to 25 at.% Cu after 300 hours at 180 C). The positron lifetime also displays an initial decrease followed by a final increase. The results confirm the hypothesis that positrons are not trapped in GP[1] zones, but show that trapping occurs in GP[2] zones formed at 150 C. During secondary ageing, the vacancy-Cu association as well as the positron lifetime decrease with the ageing time. This is attributed to the formation of GP[1] zones due to residual supersaturation. (orig.)

  11. Two-site Hubbard molecule with a spinless electron-positron pair

    KAUST Repository

    Cossu, Fabrizio

    2012-12-19

    We determine the eigenvalues of the two-site Hubbard molecule with one electron and one positron to describe the characteristics of electron-positron interactions in solids. While the effect of hopping is, in general, opposite to the effect of on-site interaction, we find a complex scenario for the electron-positron pair with a non-vanishing potential drop. We give analytical solutions and discuss the combined effects of the model parameters.

  12. Two-site Hubbard molecule with a spinless electron-positron pair

    KAUST Repository

    Cossu, Fabrizio; Schuster, Cosima; Schwingenschlö gl, Udo

    2012-01-01

    We determine the eigenvalues of the two-site Hubbard molecule with one electron and one positron to describe the characteristics of electron-positron interactions in solids. While the effect of hopping is, in general, opposite to the effect of on-site interaction, we find a complex scenario for the electron-positron pair with a non-vanishing potential drop. We give analytical solutions and discuss the combined effects of the model parameters.

  13. Positron lifetime in vanadium oxide bronzes

    International Nuclear Information System (INIS)

    Dryzek, J.; Dryzek, E.

    2003-01-01

    The positron lifetime (PL) and Doppler broadening (DB) of annihilation line measurements have been performed in vanadium oxide bronzes M x V 2 O 5 . The dependence of these annihilation characteristics on the kind and concentration of the metal M donor has been observed. In the PL spectrum only one lifetime component has been detected in all studied bronzes. The results indicate the positron localization in the structural tunnels present in the crystalline lattice of the vanadium oxide bronzes. (copyright 2003 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  14. Positron annihilation study on ZnO-based scintillating glasses

    Science.gov (United States)

    Nie, Jiaxiang; Yu, Runsheng; Wang, Baoyi; Ou, Yuwen; Zhong, Yurong; Xia, Fang; Chen, Guorong

    2009-04-01

    Positron lifetime of ZnO-based scintillating glasses (55 - x)SiO 2-45ZnO- xBaF 2 ( x = 5, 10, 15 mol%) were measured with a conventional fast-fast spectrometer. Three positron lifetime components τ1, τ 2, and τ3 are ˜0.23 ns, ˜0.45 ns, and ˜1.6 ns, respectively. All the three positron lifetime components first increase with increasing BaF 2 concentration from 5 mol% to 10 mol%, then decreases as BaF 2 further increases to 15 mol%. The result suggests that the glass sample with 10 mol% BaF 2 contains the highest defect density, and is in excellent agreement with glass chemistry, glass density, thermal properties, and calculated crystallinity. Therefore, positron annihilation lifetime measurement is an effective tool for analyzing defects in ZnO-based scintillating glasses.

  15. Characterization of point defects in CdTe by positron annihilation spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Elsharkawy, M. R. M. [Carnegie Laboratory of Physics, SUPA, School of Science and Engineering, University of Dundee, Dundee DD1 4HN (United Kingdom); Physics Department, Faculty of Science, Minia University, P.O. Box 61519, Minia (Egypt); Kanda, G. S.; Keeble, D. J., E-mail: d.j.keeble@dundee.ac.uk [Carnegie Laboratory of Physics, SUPA, School of Science and Engineering, University of Dundee, Dundee DD1 4HN (United Kingdom); Abdel-Hady, E. E. [Physics Department, Faculty of Science, Minia University, P.O. Box 61519, Minia (Egypt)

    2016-06-13

    Positron lifetime measurements on CdTe 0.15% Zn-doped by weight are presented, trapping to monovacancy defects is observed. At low temperatures, localization at shallow binding energy positron traps dominates. To aid defect identification density functional theory, calculated positron lifetimes and momentum distributions are obtained using relaxed geometry configurations of the monovacancy defects and the Te antisite. These calculations provide evidence that combined positron lifetime and coincidence Doppler spectroscopy measurements have the capability to identify neutral or negative charge states of the monovacancies, the Te antisite, A-centers, and divacancy defects in CdTe.

  16. Tomography by positrons emission

    International Nuclear Information System (INIS)

    Mosconi, Sergio L.

    1999-01-01

    The tomography by positrons emission is a technology that allows to measure the concentration of positrons emission in a tri dimensional body through external measurements. Among the isotope emissions have carbon isotopes are ( 11 C), of the oxygen ( 15 O), of the nitrogen ( 13 N) that are three the element that constitute the base of the organic chemistry. Theses have on of the PET's most important advantages, since many biological interesting organic molecules can be tracer with these isotopes for the metabolism studies 'in vivo' through PET, without using organic tracers that modify the metabolism. The mentioned isotopes, also possess the characteristic of having short lifetime, that constitute on of PET's advantages from the dosimetric point of view. Among 11 C, 15 O, and 13 N, other isotopes that can be obtained of a generator as the 68 Ga and 82 Rb

  17. SiO 2/SiC interface proved by positron annihilation

    Science.gov (United States)

    Maekawa, M.; Kawasuso, A.; Yoshikawa, M.; Itoh, H.

    2003-06-01

    We have studied positron annihilation in a Silicon carbide (SiC)-metal/oxide/semiconductor (MOS) structure using a monoenergetic positron beam. The Doppler broadening of annihilation quanta were measured as functions of the incident positron energy and the gate bias. Applying negative gate bias, significant increases in S-parameters were observed. This indicates the migration of implanted positrons towards SiO 2/SiC interface and annihilation at open-volume type defects. The behavior of S-parameters depending on the bias voltage was well correlated with the capacitance-voltage ( C- V) characteristics. We observed higher S-parameters and the interfacial trap density in MOS structures fabricated using the dry oxidation method as compared to those by pyrogenic oxidation method.

  18. SiO2/SiC interface proved by positron annihilation

    International Nuclear Information System (INIS)

    Maekawa, M.; Kawasuso, A.; Yoshikawa, M.; Itoh, H.

    2003-01-01

    We have studied positron annihilation in a Silicon carbide (SiC)-metal/oxide/semiconductor (MOS) structure using a monoenergetic positron beam. The Doppler broadening of annihilation quanta were measured as functions of the incident positron energy and the gate bias. Applying negative gate bias, significant increases in S-parameters were observed. This indicates the migration of implanted positrons towards SiO 2 /SiC interface and annihilation at open-volume type defects. The behavior of S-parameters depending on the bias voltage was well correlated with the capacitance-voltage (C-V) characteristics. We observed higher S-parameters and the interfacial trap density in MOS structures fabricated using the dry oxidation method as compared to those by pyrogenic oxidation method

  19. Positron lifetime calculation for the elements of the periodic table.

    Science.gov (United States)

    Campillo Robles, J M; Ogando, E; Plazaola, F

    2007-04-30

    Theoretical positron lifetime values have been calculated systematically for most of the elements of the periodic table. Self-consistent and non-self-consistent schemes have been used for the calculation of the electronic structure in the solid, as well as different parametrizations for the positron enhancement factor and correlation energy. The results obtained have been studied and compared with experimental data, confirming the theoretical trends. As is known, positron lifetimes in bulk show a periodic behaviour with atomic number. These calculations also confirm that monovacancy lifetimes follow the same behaviour. The effects of enhancement factors used in calculations have been commented upon. Finally, we have analysed the effects that f and d electrons have on positron lifetimes.

  20. Positron lifetime calculation for the elements of the periodic table

    International Nuclear Information System (INIS)

    Robles, J M Campillo; Ogando, E; Plazaola, F

    2007-01-01

    Theoretical positron lifetime values have been calculated systematically for most of the elements of the periodic table. Self-consistent and non-self-consistent schemes have been used for the calculation of the electronic structure in the solid, as well as different parametrizations for the positron enhancement factor and correlation energy. The results obtained have been studied and compared with experimental data, confirming the theoretical trends. As is known, positron lifetimes in bulk show a periodic behaviour with atomic number. These calculations also confirm that monovacancy lifetimes follow the same behaviour. The effects of enhancement factors used in calculations have been commented upon. Finally, we have analysed the effects that f and d electrons have on positron lifetimes

  1. Improved Slow-Positron Yield using a Single Crystal Tungsten Moderator

    DEFF Research Database (Denmark)

    Vehanen, A.; Lynn, K. G.; Schultz, P. J.

    1983-01-01

    A well-annealed W(110) single crystal was used as a fast-to-slow positron moderator. The measured moderator efficiency at room temperature using a58Co positron source in the backscattering geometry isɛ =(3.2±0.4)×10−3, roughly a factor of three better thanɛ for the best previously reported Cu(111......)+S moderator. We find a stable positron moderation efficiency over a period of several weeks when maintained at pressures around 10−9 Torr and an energy spreadΔE = 0.7 eV of the emitted slow positrons. An initial attempt was made to fabricate a hybrid Cu on W(110) moderator, which yieldedɛ of about 1...

  2. Electron-positron pair production in Coulomb collisions at ultrarelativistic energies

    International Nuclear Information System (INIS)

    Vane, C.R.; Datz, S.; Dittner, P.F.; Krause, H.F.; Bottcher, C.; Strayer, M.; Schuch, R.; Gao, H.; Hutton, R.

    1993-01-01

    We have measured angular and momentum distributions for electrons and positrons created as pairs in peripheral collisions of 6.4 TeV bare sulfur ions with fixed targets of Al, Pd, and Au. Singly- and doubly-differential cross sections have been determined for 1--17 MeV/c electrons and positrons detected independently and in coincidence as pairs. Integrated yields for pair production are found to vary as the square of the target nuclear charge. Relative angular and momentum differential cross sections are effectively target independent. Probability distributions for the pair total momentum, the positron fraction of the pair momentum, and the pair traverse momentum have been derived from the coincident electron-positron data

  3. Positrons annihilation and the Galactic center

    International Nuclear Information System (INIS)

    Wallyn, Pierre

    1992-01-01

    The Galactic center has been observed in gamma rays, many times since more than two decades and we do not still have a full comprehensive picture of this region. It is fairly well established that the 511 keV annihilation line has two origins: a steady diffuse emission, which follows more or less the type I supernovae distribution along the Galactic plane and a variable emission coming from the positrons emitted by (at least) one compact object and annihilating in a nearby cold molecular cloud. We present here an analysis of the profiles and intensifies of the 511 keV annihilation line observed in the direction of the Galactic center. We find that a warm medium (temperature of 8000 K) can describe the annihilation of positrons from the diffuse component of the line. The high state observations of the 511 keV line can be explained if the time-variable component is coming from the annihilation of the positrons in a cold medium (temperature around 80 K). This constraint on the annihilation medium temperature supports the association with the molecular cloud G-0.86-0.08 in the direction of 1E1740.7-2942. On may 22, 1989, HEXAGONE detected a narrow 511 keV line and also a broad emission around 170 keV in the direction of the Galactic center. Two weeks before, EXITE observed in the same direction a new transient source EXS 1737.9-2952 which showed a bump around 102 keV. We propose a simple semi-quantitative model which can mimic the bumps as well as its time variations and emphasize the strong similarities between EXS1737.9-2952 and Nova Muscae. We study the behaviour of positron annihilation by charge exchange in the cold phase of the interstellar medium. We calculate formula for the slowing-down time before thermalization of positrons of a given initial energy, for different medium densities. Our scenario explains the lack of detection of the recombination lines from positronium and gives new constraints on their possible observation. (author) [fr

  4. Characterization of lacunar defects by positrons annihilation

    International Nuclear Information System (INIS)

    Barthe, M.F.; Corbel, C.; Blondiaux, G.

    2003-01-01

    Among the nondestructive methods for the study of matter, the positrons annihilation method allows to sound the electronic structure of materials by measuring the annihilation characteristics. These characteristics depend on the electronic density as seen by the positon, and on the electron momentums distribution which annihilate with the positon. The positon is sensible to the coulombian potential variations inside a material and sounds preferentially the regions away from nuclei which represent potential wells. The lacunar-type defects (lack of nuclei) represent deep potential wells which can trap the positon up to temperatures close to the melting. This article describes the principles of this method and its application to the characterization of lacunar defects: 1 - positrons: matter probes (annihilation of electron-positon pairs, annihilation characteristics, positrons sources); 2 - positrons interactions in solids (implantation profiles, annihilation states, diffusion and trapping, positon lifetime spectrum: evolution with the concentration of defects); 3 - measurement of annihilation characteristics with two gamma photons (lifetime spectroscopy with the β + 22 Na isotope, spectroscopy of Doppler enlargement of the annihilation line); 4 - determination of the free volume of defects inside or at the surface of materials (annihilation signature in lacunar defects, lacuna, lacunar clusters and cavities, acceptors nature in semiconductors: ionic or lacunar, interface defects, precipitates in alloys); 5 - conclusions. (J.S.)

  5. Project of positron source at the U-120 Cyclotron, Bucharest. Status report

    International Nuclear Information System (INIS)

    Racolta, P.M.; Popa Simil, L.; Voiculescu, Dana; Miron, N.

    1999-01-01

    To extend the applications with our U-120 Cyclotron we started a project of off-line and on-line positron sources produced at the cyclotron. This machine may be successfully used for producing positron sources with few day half-life for off-line positron studies (eg. 48 V), or a cyclotron on-line intense positron beam (eg. 27 Si) with a variable energy for various materials study experiments, enough to cover a depth range from few micrometers down to tens of nanometers. Until now, using a 48 V positron source we performed experiments for determination of the Doppler broadening of the 511 KeV peak for different materials (copper, lead, indium). This research is carrier out on a cooperation agreement between IFIN-HH Bucharest and LISES-Chisinau. The positron source project is now in its initial stage. This stage consists of the experiments on the off-line version using positron sources produced in the cyclotron (eg. 48 V, 22 Na), to develop experience with detection chains (Doppler broadening and positron annihilation lifetime spectroscopy), to choose proper experiments in order to select moderator materials (W, Mo, Pt, etc.) and to study and design the different versions for the on-line production of positrons with the cyclotron. Slow positrons are valuable tools in atomic physics, materials science and solid state physics research. The controlled energy beam facility can be used to probe defects in metals, to study Fermi surfaces and materials surfaces and interfaces and to obtain detailed information about the electronic structure of materials. The aim of this project is to perform applications in the semiconductor industry, for coating materials, polymers, biomaterials etc. (authors)

  6. Project of positron source at the U-120 cyclotron Bucharest status report

    International Nuclear Information System (INIS)

    Racolta, P.M.; Simil Popa, L.; Voiculescu, Dana; Miron, N.

    2000-01-01

    To extend the applications with our U-120 Cyclotron we started a project of off-line positron sources produced at the cyclotron. This machine may be successfully used for producing positron sources with few day half-life for off-line positron studies (e.g. 48 V), or a cyclotron on-line intense positron beam (e.g. 27 Si) with a variable energy for various materials study experiments, enough to cover a depth range from a few micrometers down to tens of nanometers. Until now, using a 48 V positron source we performed experiments for determination of the Doppler broadening of the 511 keV peak for different materials (copper, lead, indium). This research is carried out on a cooperation agreement between IFIN-HH Bucharest and LISES-Chisinau. The positron source project is now in its initial stage. This stage consists of the experiments on the off-line version using positron source produced in the cyclotron (e.g. 48 V, 22 Na), to develop experience with detection chains (Doppler broadening and positron annihilation lifetime spectroscopy) to choose proper experiments in order to select moderator materials (W, Mo, Pt, etc.) and to study and design the different versions for the on-line positron production by cyclotron. Slow positrons are valuable tools in atomic physics, materials science and solid state physics research. The controlled energy beam facility can be used to probe defects in metals, to study Fermi surfaces and materials surfaces and interfaces and to obtained detailed information about electronic structures of materials. The aim of this project is to perform applications in the semiconductor industry, for coating materials, polymers, biomaterials, etc. (authors)

  7. Effects of positron density and temperature on ion-acoustic solitary waves in a magnetized electron-positron-ion plasma: Oblique propagation

    International Nuclear Information System (INIS)

    Esfandyari-Kalejahi, A.; Akbari-Moghanjoughi, M.; Mehdipoor, M.

    2009-01-01

    Ion-acoustic (IA) solitary waves are investigated in a magnetized three-component plasma consisting of cold ions, isothermal hot electrons, and positrons. The basic set of fluid equations is reduced to the Korteweg de Vries equation using the standard reductive perturbation (multiple-scale) technique. Theoretical and numerical analyses confirm significant effects of the presence of positrons and the dependence of the electron to positron temperature ratio on the amplitude and the width of IA solitary waves. It is shown that the rarefactive and compressive IA solitary excitations can propagate when the propagation angle θ satisfies 0≤θ 0 , whereas their width depends strictly on B 0 . The numerical analysis has been done based on the typical numerical data from a pulsar magnetosphere.

  8. Investigation of the crystal lattice defects by means of the positrons annihilations

    International Nuclear Information System (INIS)

    Dryzek, J.

    1994-01-01

    In this report the positrons annihilation methods as a tool for the crystal defects studies is presented. The short description of the positron - crystal interactions and different positron capture models are discussed. 192 refs, 67 figs, 6 tabs

  9. Positron annihilation studies of China's and Japan's magnesite refractory in different degree

    International Nuclear Information System (INIS)

    Zou Lin-Juan; Zhang Cai-Guo; Zhu Xiu-Ying; Sun Quin-Ying

    1989-01-01

    Studying the magnesite refractories by positron annihilation technique, the obtained results show that China's and Japan's magnesite refractories in different degree form positron lifetime results have no obvious differences in microscopical properties. According to the positron annihilation lifetime results it was found that 1650 0 C is the best sintering temperature for this material. At this temperature positive ions in MgO are replaced by impurities, the solid solubility is higher. The positron average lifetime is more even and smooth with crystallization grain size changing. When grains increase, the positron average lifetime trends towards decreasing, which is in agreement with the crystal boundary theory of ceramic material. (author)

  10. Application of positron annihilation to the characterization of polymer structure

    International Nuclear Information System (INIS)

    Suzuki, T.; Yu, R.S.; Ito, Y.; Kondo, K.; Shantarovich, V.

    2005-01-01

    Positron annihilation has been applied to study characteristics of polymers last many years. Positron behaves as a nano-meter probe and brings out information of chemical structures, geometric structures, and momentum of electrons through the annihilation gamma-rays. Positrons injected in polymers tends to form positronium, which is similar structure to hydrogen atom and consists of electron and positron. Positronium diffuses through polymer structures and preferentially trapped by intermolecular spaces, if there is not any strong polar group in the chemical structure. Inside the spaces positronium annihilates through pick-off annihilation with electrons constituting walls of the spaces. Thus the pick-off annihilation brings out information about the interaction with electrons on the walls forming the spaces. These information can be measured by the positron annihilation lifetime spectroscopy (PALS) and Doppler broadening spectroscopy: from the former lifetimes and intensities of positronium can be measured and from the latter energy spectrum of the positron annihilation gamma-rays. The lifetimes are connected with the nano-meter size of the spaces and, using an empirical formula, the pore size can be estimated quantitatively. However the intensities bring out many kinds of information. Knowing the sample chemical structures, the values can be simply connected with the amount of spaces and often reflect the polar effect and temperature effect. In the positron annihilation technique, the energy distribution of-positron annihilation gamma-rays plays important role in the investigation of positron interaction with atoms constituting polymer chemical structures. The energy distribution can be measured using a high pure Ge detector. Although the spectrum obtained by one Ge detector has a large peak to back-ground ratio, using a coincidence technique of two Ge detectors, the coincidence Doppler broadening spectrum (CDBS) can improve the ratio from the order of 10-2 to 10

  11. The PEP [positron-electron-proton] electron-positron ring: An update

    International Nuclear Information System (INIS)

    1975-03-01

    The first stage of the positron-electron-protron (PEP) colliding-beam system, which has been under joint study by a Lawrence Berkeley Laboratory--Stanford Linear Accelerator Center team for the past two years, will be the electron-positron storage ring. The physics justification for the e + e/sup /minus// ring is summarized briefly and the proposed facility is described. The ring will have six arcs having gross radii of about 220 m and six interaction regions located at the centers of straight sections about 130 m long. The longitudinal distance left free for experimental apparatus around the interaction regions was set provisionally at 20 m. The range of operating beam energies will be from 5 GeV to 15 GeV. The design luminosity at 15 GeV will be 10 32 cm/sup /minus/2/s/sup /minus/1/, and the luminosity will vary approximately as the square of the beam energy. Alternative methods under consideration for adjusting the beam cross section are discussed. The designs of the storage ring subsystems and of the conventional facilities including the experimental halls at the interaction regions are described. 7 figs., 3 tabs

  12. Analytical treatment of the nonlinear electron cloud effect and the combined effects with beam-beam and space charge nonlinear forces in storage rings

    International Nuclear Information System (INIS)

    Gao Jie

    2009-01-01

    In this paper we treat first some nonlinear beam dynamics problems in storage rings, such as beam dynamic apertures due to magnetic multipoles, wiggles, beam-beam effects, nonlinear space charge effect, and then nonlinear electron cloud effect combined with beam-beam and space charge effects, analytically. This analytical treatment is applied to BEPC II. The corresponding analytical expressions developed in this paper are useful both in understanding the physics behind these problems and also in making practical quick hand estimations. (author)

  13. Embedded design based virtual instrument program for positron beam automation

    International Nuclear Information System (INIS)

    Jayapandian, J.; Gururaj, K.; Abhaya, S.; Parimala, J.; Amarendra, G.

    2008-01-01

    Automation of positron beam experiment with a single chip embedded design using a programmable system on chip (PSoC) which provides easy interfacing of the high-voltage DC power supply is reported. Virtual Instrument (VI) control program written in Visual Basic 6.0 ensures the following functions (i) adjusting of sample high voltage by interacting with the programmed PSoC hardware, (ii) control of personal computer (PC) based multi channel analyzer (MCA) card for energy spectroscopy, (iii) analysis of the obtained spectrum to extract the relevant line shape parameters, (iv) plotting of relevant parameters and (v) saving the file in the appropriate format. The present study highlights the hardware features of the PSoC hardware module as well as the control of MCA and other units through programming in Visual Basic

  14. Application of positron emitters to studies on plants

    Energy Technology Data Exchange (ETDEWEB)

    Ishioka, N S; Matsuoka, H [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment; Sekine, T [and others

    1998-10-01

    A newly developed positron emitting tracer imaging system enables us to study dynamically the physiological function of plants, although this system covers, at present, a limited area in a plant. Production of the positron emitters {sup 11}C, {sup 13}N, {sup 18}F and {sup 48}V for this application, using an AVF cyclotron, is described. (author)

  15. Synthesis of the radiopharmaceuticals for positron emission tomography

    International Nuclear Information System (INIS)

    Biricova, V.; Kuruc, J.

    2007-01-01

    In this paper is shown a short overview of the biogenic positron radiopharmaceuticals production and a brief summary of some PET preparation synthesis. At the end the overview of some forward-looking positron radionuclides, which can be used for a preparation of the PET radiopharmaceuticals is said. A short review of diagnostic use of PET radiopharmaceuticals is presented (authors)

  16. Study of CT-based positron range correction in high resolution 3D PET imaging

    Energy Technology Data Exchange (ETDEWEB)

    Cal-Gonzalez, J., E-mail: jacobo@nuclear.fis.ucm.es [Grupo de Fisica Nuclear, Dpto. Fisica Atomica, Molecular y Nuclear, Universidad Complutense de Madrid (Spain); Herraiz, J.L. [Grupo de Fisica Nuclear, Dpto. Fisica Atomica, Molecular y Nuclear, Universidad Complutense de Madrid (Spain); Espana, S. [Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Vicente, E. [Grupo de Fisica Nuclear, Dpto. Fisica Atomica, Molecular y Nuclear, Universidad Complutense de Madrid (Spain); Instituto de Estructura de la Materia, Consejo Superior de Investigaciones Cientificas (CSIC), Madrid (Spain); Herranz, E. [Grupo de Fisica Nuclear, Dpto. Fisica Atomica, Molecular y Nuclear, Universidad Complutense de Madrid (Spain); Desco, M. [Unidad de Medicina y Cirugia Experimental, Hospital General Universitario Gregorio Maranon, Madrid (Spain); Vaquero, J.J. [Dpto. de Bioingenieria e Ingenieria Espacial, Universidad Carlos III, Madrid (Spain); Udias, J.M. [Grupo de Fisica Nuclear, Dpto. Fisica Atomica, Molecular y Nuclear, Universidad Complutense de Madrid (Spain)

    2011-08-21

    Positron range limits the spatial resolution of PET images and has a different effect for different isotopes and positron propagation materials. Therefore it is important to consider it during image reconstruction, in order to obtain optimal image quality. Positron range distributions for most common isotopes used in PET in different materials were computed using the Monte Carlo simulations with PeneloPET. The range profiles were introduced into the 3D OSEM image reconstruction software FIRST and employed to blur the image either in the forward projection or in the forward and backward projection. The blurring introduced takes into account the different materials in which the positron propagates. Information on these materials may be obtained, for instance, from a segmentation of a CT image. The results of introducing positron blurring in both forward and backward projection operations was compared to using it only during forward projection. Further, the effect of different shapes of positron range profile in the quality of the reconstructed images with positron range correction was studied. For high positron energy isotopes, the reconstructed images show significant improvement in spatial resolution when positron range is taken into account during reconstruction, compared to reconstructions without positron range modeling.

  17. Study of CT-based positron range correction in high resolution 3D PET imaging

    International Nuclear Information System (INIS)

    Cal-Gonzalez, J.; Herraiz, J.L.; Espana, S.; Vicente, E.; Herranz, E.; Desco, M.; Vaquero, J.J.; Udias, J.M.

    2011-01-01

    Positron range limits the spatial resolution of PET images and has a different effect for different isotopes and positron propagation materials. Therefore it is important to consider it during image reconstruction, in order to obtain optimal image quality. Positron range distributions for most common isotopes used in PET in different materials were computed using the Monte Carlo simulations with PeneloPET. The range profiles were introduced into the 3D OSEM image reconstruction software FIRST and employed to blur the image either in the forward projection or in the forward and backward projection. The blurring introduced takes into account the different materials in which the positron propagates. Information on these materials may be obtained, for instance, from a segmentation of a CT image. The results of introducing positron blurring in both forward and backward projection operations was compared to using it only during forward projection. Further, the effect of different shapes of positron range profile in the quality of the reconstructed images with positron range correction was studied. For high positron energy isotopes, the reconstructed images show significant improvement in spatial resolution when positron range is taken into account during reconstruction, compared to reconstructions without positron range modeling.

  18. Advances in positron and electron scattering*

    Science.gov (United States)

    Limão-Vieira, Paulo; García, Gustavo; Krishnakumar, E.; Petrović, Zoran; Sullivan, James; Tanuma, Hajime

    2016-10-01

    The topical issue on Advances in Positron and Electron Scattering" combines contributions from POSMOL 2015 together with others devoted to celebrate the unprecedented scientific careers of our loyal colleagues and trusted friends Steve Buckman (Australian National University, Australia) and Michael Allan (University of Fribourg, Switzerland) on the occasion of their retirements. POSMOL 2015, the XVIII International Workshop on Low-Energy Positron and Positronium Physics and the XIX International Symposium on Electron-Molecule Collisions and Swarms, was held at Universidade NOVA de Lisboa, Lisboa, Portugal, from 17-20 July 2015. The international workshop and symposium allowed to achieve a very privileged forum of sharing and developing our scientific expertise on current aspects of positron, positronium and antiproton interactions with electrons, atoms, molecules and solid surfaces, and related topics, as well as electron interactions with molecules in both gaseous and condensed phases. Particular topics include studies of electron interactions with biomolecules, electron induced surface chemistry and the study of plasma processes. Recent developments in the study of swarms are also fully addressed.

  19. Mathematical modeling of elementary trapping-reduction processes in positron annihilation lifetime spectroscopy: methodology of Ps-to-positron trapping conversion

    Science.gov (United States)

    Shpotyuk, Ya; Cebulski, J.; Ingram, A.; Shpotyuk, O.

    2017-12-01

    Methodological possibilities of positron annihilation lifetime (PAL) spectroscopy in application to nanostructurized substances treated within three-term fitting procedure are reconsidered to parameterize their atomic-deficient structural arrangement. In contrast to conventional three-term fitting analysis of the detected PAL spectra based on admixed positron trapping and positronium (Ps) decaying, the nanostructurization due to guest nanoparticles embedded in host matrix is considered as producing modified trapping, which involves conversion between these channels. The developed approach referred to as x3-x2-coupling decomposition algorithm allows estimation free volumes of interfacial voids responsible for positron trapping and bulk lifetimes in nanoparticle-embedded substances. This methodology is validated using experimental data of Chakraverty et al. [Phys. Rev. B71 (2005) 024115] on PAL study of composites formed by guest NiFe2O4 nanocrystals grown in host SiO2 matrix.

  20. Positron annihilation and pressure-induced electronic s-d transition

    International Nuclear Information System (INIS)

    McMahan, A.K.; Skriver, H.L.

    1985-06-01

    The polycrystalline, partial annihilation rates for positrons in compressed cesium have been calculated using the linear muffin-tin orbitals method. These results suggest that the pressure-induced electronic s-d transition in Cs should be directly observable by momentum sensitive positron annihilation experiments