WorldWideScience

Sample records for benign pulmonary nodules

  1. Clinical application and progress of PET and PET-CT for differential diagnosis of the benign or malignant pulmonary nodules

    International Nuclear Information System (INIS)

    Wang Xuemei; Wang Meiling; Wang Xiangcheng

    2010-01-01

    To differential diagnosis the benign or malignant of pulmonary nodules is a medical difficult problem. As the development of medical imaging equipment and technology, PET-CT can identified benign or malignant lesions of pulmonary nodules though changes of metabolism. Researches about PET-CT for differential diagnosis pulmonary nodules benign or malignant are reviewed. (authors)

  2. Benign pulmonary nodule. Morphological features and contrast enhancement evaluated with contiguous thin-section CT

    Energy Technology Data Exchange (ETDEWEB)

    Matsuo, Hisayasu; Murata, Kiyoshi; Takahashi, Masashi; Morita, Rikushi [Shiga Univ. of Medical Science, Otsu (Japan)

    1998-10-01

    The morphological changes in 54 benign lung nodules, including 8 histologically proven nodules of tuberculoma, 10 of focal organizing pneumonia (FOP), 1 of lung abscess and 35 other benign nodules, were evaluated with contiguous thin-section (3 mm) CT. In addition, incremental dynamic studies were carried out in 25 of these nodules. The three-dimensional shapes of the nodules were found to be quite varied and were classified into four types: round mass (n=18), polygonal mass with concave or straight margins (n=20), oval or band-like mass extending along the bronchovascular bundle (n=7), and oval mass attached to the pleura with broad contact (n=9). Forty-two (78%) of the 54 nodules were located along the bronchovascular bundle. The maximum increments in CT values over 20 HU were observed after contrast enhancement in 18 (72%) of the 25 benign nodules, among which all tuberculomas showed little or no contrast enhancement. The number of small vessels quantified microscopically in the center of the nodules were minimal in tuberculomas with little enhancement and plentiful in lesions of FOP and abscess which showed marked enhancement. Our results suggest that the differentiation between benign and malignant pulmonary nodules is not possible simply on the basis of the degree of contrast enhancement. Therefore, morphological features and the anatomical relation to the bronchovascular bundles should also be taken into consideration in the diagnosis of pulmonary nodules. (author)

  3. Benign pulmonary nodule. Morphological features and contrast enhancement evaluated with contiguous thin-section CT

    International Nuclear Information System (INIS)

    Matsuo, Hisayasu; Murata, Kiyoshi; Takahashi, Masashi; Morita, Rikushi

    1998-01-01

    The morphological changes in 54 benign lung nodules, including 8 histologically proven nodules of tuberculoma, 10 of focal organizing pneumonia (FOP), 1 of lung abscess and 35 other benign nodules, were evaluated with contiguous thin-section (3 mm) CT. In addition, incremental dynamic studies were carried out in 25 of these nodules. The three-dimensional shapes of the nodules were found to be quite varied and were classified into four types: round mass (n=18), polygonal mass with concave or straight margins (n=20), oval or band-like mass extending along the bronchovascular bundle (n=7), and oval mass attached to the pleura with broad contact (n=9). Forty-two (78%) of the 54 nodules were located along the bronchovascular bundle. The maximum increments in CT values over 20 HU were observed after contrast enhancement in 18 (72%) of the 25 benign nodules, among which all tuberculomas showed little or no contrast enhancement. The number of small vessels quantified microscopically in the center of the nodules were minimal in tuberculomas with little enhancement and plentiful in lesions of FOP and abscess which showed marked enhancement. Our results suggest that the differentiation between benign and malignant pulmonary nodules is not possible simply on the basis of the degree of contrast enhancement. Therefore, morphological features and the anatomical relation to the bronchovascular bundles should also be taken into consideration in the diagnosis of pulmonary nodules. (author)

  4. Relation between nodule size and 18F-FDG-PET SUV for malignant and benign pulmonary nodules.

    Directory of Open Access Journals (Sweden)

    Shao Yiping

    2008-09-01

    Full Text Available Abstract The most common semiquantitative method of evaluation of pulmonary lesions using 18F-FDG PET is FDG standardized uptake value (SUV. An SUV cutoff of 2.5 or greater has been used to differentiate between benign and malignant nodules. The goal of our study was to investigate the correlation between the size of pulmonary nodules and the SUV for benign as well as for malignant nodules. Methods Retrospectively, 173 patients were selected from 420 referrals for evaluation of pulmonary lesions. All patients selected had a positive CT and PET scans and histopathology biopsy. A linear regression equation was fitted to a scatter plot of size and SUVmax for malignant and benign nodules together. A dot diagram was created to calculate the sensitivity, specificity, and accuracy using an SUVmax cutoff of 2.5. Results The linear regression equations and (R2s as well as the trendlines for malignant and benign nodules demonstrated that the slope of the regression line is greater for malignant than for benign nodules. Twenty-eight nodules of group one (≤ 1.0 cm are plotted in a dot diagram using an SUVmax cutoff of 2.5. The sensitivity, specificity, and accuracy were calculated to be 85%, 36% and 54% respectively. Similarly, sensitivity, specificity, and accuracy were calculated for an SUVmax cutoff of 2.5 and found to be 91%, 47%, and 79% respectively for group 2 (1.1–2.0 cm; 94%, 23%, and 76%, respectively for group 3 (2.1–3.0 cm; and 100%, 17%, and 82%,, respectively for group 4 (> 3.0 cm. The previous results of the dot diagram indicating that the sensitivity and the accuracy of the test using an SUVmax cutoff of 2.5 are increased with an increase in the diameter of pulmonary nodules. Conclusion The slope of the regression line is greater for malignant than for benign nodules. Although, the SUVmax cutoff of 2.5 is a useful tool in the evaluation of large pulmonary nodules (> 1.0 cm, it has no or minimal value in the evaluation of small

  5. Benign metastasizing leiomyoma presenting as multiple cystic pulmonary nodules: a case report.

    Science.gov (United States)

    Choe, Yeong Hun; Jeon, So Yeon; Lee, Yoon Chae; Chung, Myung Ja; Park, Seung Yong; Lee, Yong Chul; Kim, So Ri

    2017-09-12

    Benign metastatic leiomyoma (BML) is an extremely rare disease. Although uterine leiomyomas are benign histologically, they can metastasize to distant sites. While the incidence is very low, the lung is the organ most frequently affected by BML. Pulmonary BML usually presents as numerous well-defined nodules of various sizes, while the cavitary or cystic features in the nodules are rarely observed on radiologic images. A 52-year-old woman complained of cough and dyspnea for one month. She had been previously diagnosed with uterine leiomyoma and had undergone total hysterectomy about 14 years prior. High-resolution computed tomography (CT) images showed that there were multiple cystic nodules of various sizes in both lungs. Pathologic examination revealed that the pulmonary nodule had complex branching glandular structures lined by a single layer of simple cuboidal to columnar epithelium that was surrounded by abundant spindle cells. Additional immunohistochemistry data suggested that pulmonary nodule diagnosis was BML-associated uterine leiomyoma. In this report, we introduce an interesting case of pulmonary BML that presented as a combination of various kinds of nodules including simple round nodules, simple cysts, and cysts with a solid portion, which are very rare radiologic features of BML in lung. In addition, when the patient is a woman of reproductive age, physicians should meticulously review the gynecological history and suspect BML when there are various cystic pulmonary lesions.

  6. Automated computerized scheme for distinction between benign and malignant solitary pulmonary nodules on chest images

    International Nuclear Information System (INIS)

    Aoyama, Masahito; Li Qiang; Katsuragawa, Shigehiko; MacMahon, Heber; Doi, Kunio

    2002-01-01

    A novel automated computerized scheme has been developed to assist radiologists for their distinction between benign and malignant solitary pulmonary nodules on chest images. Our database consisted of 55 chest radiographs (33 primary lung cancers and 22 benign nodules). In this method, the location of a nodule was indicated first by a radiologist. The difference image with a nodule was produced by use of filters and then represented in a polar coordinate system. The nodule was segmented automatically by analysis of contour lines of the gray-level distribution based on the polar-coordinate representation. Two clinical parameters (age and sex) and 75 image features were determined from the outline, the image, and histogram analysis for inside and outside regions of the segmented nodule. Linear discriminant analysis (LDA) and knowledge about benign and malignant nodules were used to select initial feature combinations. Many combinations for subgroups of 77 features were evaluated as input to artificial neural networks (ANNs). The performance of ANNs with the selected 7 features by use of the round-robin test showed Az=0.872, which was greater than Az=0.854 obtained previously with the manual method (P=0.53). The performance of LDA (Az=0.886) was slightly improved compared to that of ANNs (P=0.59) and was greater than that of the manual method (Az=0.854) reported previously (P=0.40). The high level of its performance indicates the potential usefulness of this automated computerized scheme in assisting radiologists as a second opinion for distinction between benign and malignant solitary pulmonary nodules on chest images

  7. Incidental multiple pulmonary nodules: benign metastasizing leiomyoma and 18F-FDG PET/CT

    International Nuclear Information System (INIS)

    Lee, Seok Mo

    2007-01-01

    Benign metastasizing leiomyoma(BML) is a rare condition affecting women with a history of having undergone hysterectomy or myomectomy for a benign uterine fibroid, that is found to have metastasized to extrauterine sites, usually many years after hysterectomy. 1,2) Patient with BML almost always asymptomatic, although if the lesions are large enough, they can cause compressive symptoms. Among several hypothesis of pathogenesis, most plausible theory is that these tumors represent a true metastatic lesion but are very low-grade sarcoma. 3) Because the tumor is responsive to estrogen, menopause and pregnancy have slowed the growth of these lesion 4) and it seems reasonable to perform hysterectomy in patients with a uterine mass and, at the same time, perform oophorectomy for hormonal control. BML is an unusual cause of diffuse pulmonary nodules which should be considered in females with unexplained nodules and a history of surgery for uterine leiomyoma

  8. Incidental multiple pulmonary nodules: benign metastasizing leiomyoma and {sup 18}F-FDG PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seok Mo [Kosin University Medical School, Busan (Korea, Republic of)

    2007-06-15

    Benign metastasizing leiomyoma(BML) is a rare condition affecting women with a history of having undergone hysterectomy or myomectomy for a benign uterine fibroid, that is found to have metastasized to extrauterine sites, usually many years after hysterectomy. 1,2) Patient with BML almost always asymptomatic, although if the lesions are large enough, they can cause compressive symptoms. Among several hypothesis of pathogenesis, most plausible theory is that these tumors represent a true metastatic lesion but are very low-grade sarcoma. 3) Because the tumor is responsive to estrogen, menopause and pregnancy have slowed the growth of these lesion 4) and it seems reasonable to perform hysterectomy in patients with a uterine mass and, at the same time, perform oophorectomy for hormonal control. BML is an unusual cause of diffuse pulmonary nodules which should be considered in females with unexplained nodules and a history of surgery for uterine leiomyoma.

  9. The usefulness of F-18 FDG PET to discriminate between malignant and benign nodule in idiopathic pulmonary fibrosis

    International Nuclear Information System (INIS)

    Kim, Bom Sahn; Kang, Won Jun; Lee, Dong Soo; Chung, June Key; Lee, Myung Chul

    2006-01-01

    Incidence of lung cancer in patients with idiopathic pulmonary fibrosis (IPF) is known to be higher than that in general population. However, it is difficult to discriminate pulmonary nodule in patients with IPF, because underlying IPF can be expressed as lung nodules. We evaluated the diagnostic performance of FDG PET in discriminating lung nodule in patients with IPF. We retrospectively reviewed 28 lung nodules in 16 subjects (age; 67.53 ± 9.83, M:F = 14:2). Two patients had previous history of malignant cancer (small cell lung cancer and subglottic cancer). The diagnostic criteria on chest CT were size, morphology and serial changes of size. FDG PET was visually interpreted, and maximal SUV was calculated for quantitative analysis. From 28 nodules, 18 nodules were interpreted as benign nodules, 10 nodules as malignant nodules by histopathology or follow-up chest CT. The sensitivity and specificity of FDG PET were 100% and 94.4%, while those of CT were 70.0% and 44.4% respectively. Malignant nodule was higher maxSUV than that of benign lung nodules (7.68 ± 3.96 vs 1.22 ± 0.65, p < 0.001). Inflammatory lesion in underlying IPF was significantly lower masSUV than that of malignant nodules (1.80 ± 0.43, p < 0.001). The size of malignant and benign nodule were 23.95 ± 10.15 mm and 10.83 ± 5.23 mm p < 0.01) FDG PET showed superior diagnostic performance to chest CT in differentiating lung nodules in patients with underlying IPF. FDG PET could be used to evaluate suspicious malignant nodule detected by chest in patients with IPF

  10. The usefulness of F-18 FDG PET to discriminate between malignant and benign nodule in idiopathic pulmonary fibrosis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bom Sahn; Kang, Won Jun; Lee, Dong Soo; Chung, June Key; Lee, Myung Chul [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2006-06-15

    Incidence of lung cancer in patients with idiopathic pulmonary fibrosis (IPF) is known to be higher than that in general population. However, it is difficult to discriminate pulmonary nodule in patients with IPF, because underlying IPF can be expressed as lung nodules. We evaluated the diagnostic performance of FDG PET in discriminating lung nodule in patients with IPF. We retrospectively reviewed 28 lung nodules in 16 subjects (age; 67.53 {+-} 9.83, M:F = 14:2). Two patients had previous history of malignant cancer (small cell lung cancer and subglottic cancer). The diagnostic criteria on chest CT were size, morphology and serial changes of size. FDG PET was visually interpreted, and maximal SUV was calculated for quantitative analysis. From 28 nodules, 18 nodules were interpreted as benign nodules, 10 nodules as malignant nodules by histopathology or follow-up chest CT. The sensitivity and specificity of FDG PET were 100% and 94.4%, while those of CT were 70.0% and 44.4% respectively. Malignant nodule was higher maxSUV than that of benign lung nodules (7.68 {+-} 3.96 vs 1.22 {+-} 0.65, p < 0.001). Inflammatory lesion in underlying IPF was significantly lower masSUV than that of malignant nodules (1.80 {+-} 0.43, p < 0.001). The size of malignant and benign nodule were 23.95 {+-} 10.15 mm and 10.83 {+-} 5.23 mm p < 0.01) FDG PET showed superior diagnostic performance to chest CT in differentiating lung nodules in patients with underlying IPF. FDG PET could be used to evaluate suspicious malignant nodule detected by chest in patients with IPF.

  11. Differentiation of malignant and benign pulmonary nodules with first-pass dual-input perfusion CT

    International Nuclear Information System (INIS)

    Yuan, Xiaodong; Quan, Changbin; Cao, Jianxia; Ao, Guokun; Tian, Yuan; Li, Hong; Zhang, Jing

    2013-01-01

    To assess diagnostic performance of dual-input CT perfusion for distinguishing malignant from benign solitary pulmonary nodules (SPNs). Fifty-six consecutive subjects with SPNs underwent contrast-enhanced 320-row multidetector dynamic volume CT. The dual-input maximum slope CT perfusion analysis was employed to calculate the pulmonary flow (PF), bronchial flow (BF), and perfusion index (PI,=PF/(PF+BF)). Differences in perfusion parameters between malignant and benign tumours were assessed with histopathological diagnosis as the gold standard. Diagnostic value of the perfusion parameters was calculated using the receiver-operating characteristic (ROC) curve analysis. Amongst 56 SPNs, statistically significant differences in all three perfusion parameters were revealed between malignant and benign tumours. The PI demonstrated the biggest difference between malignancy and benignancy: 0.30 ± 0.07 vs. 0.51 ± 0.13, P < 0.001. The area under the PI ROC curve was 0.92, the largest of the three perfusion parameters, producing a sensitivity of 0.95, specificity of 0.83, positive likelihood ratio (+LR) of 5.59, and negative likelihood ratio (-LR) of 0.06 in identifying malignancy. The PI derived from the dual-input maximum slope CT perfusion analysis is a valuable biomarker for identifying malignancy in SPNs. PI may be potentially useful for lung cancer treatment planning and forecasting the therapeutic effect of radiotherapy treatment. (orig.)

  12. Computed tomography of pulmonary nodules

    International Nuclear Information System (INIS)

    Nakata, Hajime; Honda, Hiroshi; Nakayama, Chikashi; Kimoto, Tatsuya; Nakayama, Takashi

    1983-01-01

    We have evaluated the value of computed tomography (CT) in distinguishing benign and malignant pulmonary nodules. CT was performed on 30 cases of solitary pulmonary nodules consisting of 17 primary lung cancers, 3 metastatic tumors and 10 benign nodules. The CT number was calculated for each lesion. Three benign nodules showed CT numbers well above the range of malignant nodules, and only in one of them was calcification visible on conventional tomography. In 6 benign nodules, the CT numbers overlapped those of malignant lesion and could not be differentiated. Thus the measurement of CT number can be useful to confirm the benign nature of certain nodules when calcification is unclear or not visible on conventional tomography. As for the morphological observation of the nodule, CT was not superior to conventional tomography and its value seems to be limited. (author)

  13. Role of baseline nodule density and changes in density and nodule features in the discrimination between benign and malignant solid indeterminate pulmonary nodules

    NARCIS (Netherlands)

    Xu, D.M.; van Klaveren, R.J.; de Bock, G.H.; Leusveld, A.L.M.; Dorrius, M.D.; Zhao, Y.; Wang, Y.; de Koning, H.J.; Scholten, E.T.; Verschakelen, J.; Prokop, M.; Oudkerk, M.

    Purpose: To retrospectively evaluate whether baseline nodule density or changes in density or nodule features could be used to discriminate between benign and malignant solid indeterminate nodules. Materials and methods: Solid indeterminate nodules between 50 and 500 mm(3) (4.6-9.8 mm) were assessed

  14. Differentiation of benign and malignant solitary pulmonary nodules : value of contrast-enhanced dynamic MR imaging

    International Nuclear Information System (INIS)

    Kim, Jeong Ho; Kim, Hyung Jin; Han, Heon; Lee, Hong Lyeol; Kim, Kwang Ho; Suh, Chang Hae

    1999-01-01

    To evaluate the usefulness of contrast-enhanced dynamic MR imaging for differentiation of benign and malignant solitary pulmonary nodules (SPNs). Twenty-three patients with histologically or radiologically provened SPNs smaller than 40mm (14 benign, 9 malignant) underwent MR examination using the breath-hold fast multiplanar spoiled gradient echo (FMPSPGR) technique. Pre-enhancement MR examination was followed by serial scans obtained at one-minute intervals, beginning one-minute after the onset of bolus injection of paramagnetic contrast agent for a total of five scans. Signal intensities of SPNs were measured from pre- and post-contrast enhanced MR images and peak percentage increase in signal intensity (p%SI) was calculated. Mean percentage increase in signal intensity (m%SI) was also calculated and the time-m%SI curve was plotted. The enhancement patterns of SPNs were classified as homogeneous, peripheral rim-like, inhomogeneous, or no (or minimal) enhancement. We compared differences in p%SI, the pattern of the time-m%SI curve, and the pattern of enhancement between benign and malignant SPNs. On dynamic MR images, alignant SPNs (n=9) showed a significantly higher p%SI than benign SPNs (n=14) (malignant : mean 120.6, range 81.8-171.6; benign : mean 29.5, range 3.7-78.9)(p<0.0001). With 80 p%SI as the threshold for malignancy-positive, both sensitivity and specificity were 100%. The m%SI of malignant SPNs rapidly increased at one minute after enhancement and decreased gradually thereafter, whereas that of benign SPNs increased more slowly to form a plateau. Eighty-nine percent (8/9) of malignant SPNs showed homogeneous enhancement. In contrast, among benign SPNs, peripheral rim-like enhancement and no (or minimal) enhancement occurred in the same proportion of cases : 50%(7/14). The superb demonstration of different enhancement characteristics obtained using dynamic contrast-enhanced MR imaging is useful to discriminate malignant from benign SPNs

  15. Evaluation of PET/CT combined with HRCT in differentiating malignant from benign solitary pulmonary nodules

    International Nuclear Information System (INIS)

    Ge Quanxu; Zhu Renjuan; Liu Qingwei; Lv Shouchen; Yao Shuzhan; Li Xin

    2005-01-01

    Objective: To investigate the clinical value of 18 F-fluorodeoxyglucose (FDG) PET/CT combined with high resolution CT (HRCT) to differentiate solitary pulmonary nodule (SPN). Methods: 25 patients with 27 SPN were examined with 18 F-FDG PET/CT and HRCT, all of them were proved pathologically or by follow-up. The differential diagnosis of SPN were made using visual method and semi-quantitative method on PET/CT and morphological characteristics on HRCT. The results of 18 F-FDG PET/CT and 18 F-FDG PET/CT combined with HRCT were compared with pathological results. Results: 15 were malignant and 12 benign among the 27 SPN. 14 SPN were positive on PET/CT among 15 malignant SPN with only one negative less than 10 mm in size. 3 benign were positive on PET/CT, but 2 of them were correctly diagnosed as benign by PET/CT combined with HRCT. The specificity, negative predictive value and accuracy of 18 F-FDG PET/CT combined with HRCT were higher than that of PET/CT (91.7%, 93.3%, 91.7% and 93.7% vs 75.0%, 82.4%, 90.0% and 85.2% ). The sensitivity of PET/CT combined with HRCT and PET/CT alone was same (93.3%). Conclusion: 18 F-FDG PET/CT combined with HRCT is a effective no-invasive method in differentiating malignant SPN from benign. (authors)

  16. Solitary pulmonary nodule

    Science.gov (United States)

    ... Adenocarcinoma - chest x-ray Pulmonary nodule - front view chest x-ray Pulmonary nodule, solitary - CT scan Respiratory system References Gotway MB, Panse PM, Gruden JF, Elicker BM. Thoracic radiology: noninvasive diagnostic imaging. In: Broaddus VC, Mason RJ, ...

  17. Usefulness of dynamic MR imaging for the evaluation of the solitary pulmonary nodules smaller than 15 mm: differentiation between benign and malignant nodules

    International Nuclear Information System (INIS)

    Park, Sang Hee; Jin, Gong Yong; Han, Young Min; Chung, Gyung Ho; Kwon, Keun Sang

    2005-01-01

    We wanted to evaluate the usefulness of dynamic magnetic resonance (MR) imaging for differentiating between benign and malignant solitary pulmonary nodules (SPNs). Sixteen patients who had an undetermined SPN (< 15mm) upon chest computed tomography (8 males and 8 females; mean age: 55 years; age range: 40-76 years) underwent dynamic MR imaging. After the bolus injection of contrast material, the arterial (20-35 seconds), portal (45-60 seconds) and equilibrium (3-5 minutes) phase T1-weighted axial images were obtained with using a volumetric interpolated breath-hold examination. For discriminating the benign from malignant SPNs, the maximum relative enhancement ratio (MER) and the slope of the enhancement (SLE) were calculated and then they were statistically compared. With varying the threshold of the two indexes, the sensitivity, specificity, positive predictive value, negative predictive value and accuracy were calculated. The mean MER of the malignant SPN group was significantly higher than that of the benign SPN group (malignant; 0.56 ± 0.17, benign; 0.43 ± 0.17). With 0.33 as the threshold of MER for distinguishing the malignant SPN group from the benign SPN group, the sensitivity, specificity, positive predictive value and negative predictive value were 100%, 70%, 50%, and 100%, respectively. The mean SLE for the benign SPN group was higher than that for the malignant SPN group (malignant; m= 0.008 ± 0.006/sec, benign; m=0.013 ±0.008/sec). With 0.025 as the threshold of the SLE, the sensitivity, specificity, positive predictive value, negative predictive value and accuracy were 100%, 60%, 62.5%, 100% and 69.2%, respectively. Dynamic MRI was useful for differentiating between benign and malignant SPNs. Moreover, MER and SLE might be good indexes for distinguishing benign SPNs from malignant SPNs

  18. Analysis of the discriminative methods for diagnosis of benign and malignant solitary pulmonary nodules based on serum markers.

    Science.gov (United States)

    Wang, Wanping; Liu, Mingyue; Wang, Jing; Tian, Rui; Dong, Junqiang; Liu, Qi; Zhao, Xianping; Wang, Yuanfang

    2014-01-01

    Screening indexes of tumor serum markers for benign and malignant solitary pulmonary nodules (SPNs) were analyzed to find the optimum method for diagnosis. Enzyme-linked immunosorbent assays, an automatic immune analyzer and radioimmunoassay methods were used to examine the levels of 8 serum markers in 164 SPN patients, and the sensitivity for differential diagnosis of malignant or benign SPN was compared for detection using a single plasma marker or a combination of markers. The results for serological indicators that closely relate to benign and malignant SPNs were screened using the Fisher discriminant analysis and a non-conditional logistic regression analysis method, respectively. The results were then verified by the k-means clustering analysis method. The sensitivity when using a combination of serum markers to detect SPN was higher than that using a single marker. By Fisher discriminant analysis, cytokeratin 19 fragments (CYFRA21-1), carbohydrate antigen 125 (CA125), squamous cell carcinoma antigen (SCC) and breast cancer antigen (CA153), which relate to the benign and malignant SPNs, were screened. Through non-conditional logistic regression analysis, CYFRA21-1, SCC and CA153 were obtained. Using the k-means clustering analysis, the cophenetic correlation coefficient (0.940) obtained by the Fisher discriminant analysis was higher than that obtained with logistic regression analysis (0.875). This study indicated that the Fisher discriminant analysis functioned better in screening out serum markers to recognize the benign and malignant SPN. The combined detection of CYFRA21-1, CA125, SCC and CA153 is an effective way to distinguish benign and malignant SPN, and will find an important clinical application in the early diagnosis of SPN. © 2014 S. Karger GmbH, Freiburg.

  19. Management of Pulmonary Nodules

    OpenAIRE

    Arvin Aryan

    2010-01-01

    Pulmonary nodule characterization is currently being redefined as new clinical, radiological and pathological data are reported, necessitating a reevaluation of the clinical management."nIn approach to an incidentally detected pulmonary nodule, we should consider that there are different risk situations, different lesion morphologies, and different sizes with various management options."nIn this session we will review the different risk situations for patients with pulmonary nodules...

  20. Indeterminate Pulmonary Nodules at Colorectal Cancer Staging

    DEFF Research Database (Denmark)

    Nordholm-Carstensen, Andreas; Wille-Jørgensen, Peer A; Jorgensen, Lars N

    2013-01-01

    This study aimed to estimate the prevalence of indeterminate pulmonary nodules and specific radiological and clinical characteristics that predict malignancy of these at initial staging chest computed tomography (CT) in patients with colorectal cancer. A considerable number of indeterminate...... pulmonary nodules, which cannot readily be classified as either benign or malignant, are detected at initial staging chest CT in colorectal cancer patients....

  1. Management of an incidentally discovered pulmonary nodule

    International Nuclear Information System (INIS)

    Beigelman-Aubry, Catherine; Hill, Catherine; Grenier, Philippe A.

    2007-01-01

    The incidental finding of a pulmonary nodule on computed tomography (CT) is becoming an increasingly frequent event. The discovery of such a nodule should evoke the possibility of a small bronchogenic carcinoma, for which excision is indicated without delay. However, invasive diagnostic procedures should be avoided in the case of a benign lesion. The objectives of this review article are: (1) to analyze the CT criteria defining benign nodules, nodules of high suspicion of malignancy and indeterminate nodules, (2) to analyze the diagnostic performances and limitations of complementary investigations requested to characterize indeterminate lung nodules, (3) to review the criteria permitting to assess the probability of malignancy of indeterminate nodules and (4) to report on the new guidelines provided by the Fleischner Society for the management of small indeterminate pulmonary nodules, according to their prior probability of malignancy. (orig.)

  2. Visual and semiquantitative analysis of 18F-fluorodeoxyglucose positron emission tomography using a partial-ring tomograph without attenuation correction to differentiate benign and malignant pulmonary nodules

    International Nuclear Information System (INIS)

    Skehan, S.J.; Coates, G.; Otero, C.; O'Donovan, N.; Pelling, M.; Nahmias, C.

    2001-01-01

    Many studies have reported the use of attenuation-corrected positron emission tomography with 18 F-fluorodeoxyglucose (FDG PET) with full-ring tomographs to differentiate between benign and malignant pulmonary nodules. We sought to evaluate FDG PET using a partial-ring tomograph without attenuation correction. A retrospective review of PET images from 77 patients (range 38-84 years of age) with proven benign or malignant pulmonary nodules was undertaken. All images were obtained using a Siemens/CTI ECAT ART tomograph, without attenuation correction, after 185 MBq 18 F-FDG was injected. Images were visually graded on a 5-point scale from 'definitely malignant' to 'definitely benign,' and lesion-to-background (LB) ratios were calculated using region of interest analysis. Visual and semiquantitative analyses were compared using receiver operating characteristic analysis. Twenty lesions were benign and 57 were malignant. The mean LB ratio for benign lesions was 1.5 (range 1.0-5.7) and for malignant lesions 5.7 (range 1.2-14.1) (p < 0.001). The area under the ROC curve for LB ratio analysis was 0.95, and for visual analysis 0.91 (p = 0.39). The optimal cut-off ratio with LB ratio analysis was 1.8, giving a sensitivity of 95% and a specificity of 85%. For lesions thought to be 'definitely malignant' on visual analysis, the sensitivity was 93% and the specificity 85%. Three proven infective lesions were rated as malignant by both techniques (LB ratio 2.6-5.7). FDG PET without attenuation correction is accurate for differentiating between benign and malignant lung nodules. Results using simple LB ratios without attenuation correction compare favourably with the published sensitivity and specificity for standard uptake ratios. Visual analysis is equally accurate. (author)

  3. Detection of pulmonary nodules

    International Nuclear Information System (INIS)

    Vanzulli, A.; Zanello, A.; DelMaschio, M.; Paesano, P.; Panizza, P.; DelMaschio, A.

    1989-01-01

    The authors have prospectively studied 203 pulmonary nodules in 91 patients, selected by CT (gold standard), with both subtraction digital radiography (SDR) and conventional plain film. Subtracted images were obtained by using copper filter inserted between two photostimulable imaging plates. Five radiologists randomly analyzed all conventional and subtracted images. The authors calculated sensitivity, specificity, and positive and negative predictive values for both conventional radiography and SDR. Receiver operating characteristics (ROC) curves were calculated by plotting the number of nodules detected with different degrees of confidence. SDR detected 12% more nodules than conventional radiography. ROC curves demonstrated that the level of confidence was better for SDR (P <.05)

  4. Dynamic contrast-enhanced MRI versus 18F-FDG PET/CT: Which is better in differentiation between malignant and benign solitary pulmonary nodules?

    Science.gov (United States)

    Feng, Feng; Qiang, Fulin; Shen, Aijun; Shi, Donghui; Fu, Aiyan; Li, Haiming; Zhang, Mingzhu; Xia, Ganlin; Cao, Peng

    2018-02-01

    To prospectively compare the discriminative capacity of dynamic contrast enhanced-magnetic resonance imaging (DCE-MRI) with that of 18 F-fluorodeoxyglucose ( 18 F-FDG) positron emission tomography/computed tomography (PET/CT) in the differentiation of malignant and benign solitary pulmonary nodules (SPNs). Forty-nine patients with SPNs were included in this prospective study. Thirty-two of the patients had malignant SPNs, while the other 17 had benign SPNs. All these patients underwent DCE-MRI and 18 F-FDG PET/CT examinations. The quantitative MRI pharmacokinetic parameters, including the trans-endothelial transfer constant (K trans ), redistribution rate constant (K ep ), and fractional volume (V e ), were calculated using the Extended-Tofts Linear two-compartment model. The 18 F-FDG PET/CT parameter, maximum standardized uptake value (SUV max ), was also measured. Spearman's correlations were calculated between the MRI pharmacokinetic parameters and the SUV max of each SPN. These parameters were statistically compared between the malignant and benign nodules. Receiver operating characteristic (ROC) analyses were used to compare the diagnostic capability between the DCE-MRI and 18 F-FDG PET/CT indexes. Positive correlations were found between K trans and SUV max , and between K ep and SUV max (P0.05). DCE-MRI can be used to differentiate between benign and malignant SPNs and has the advantage of being radiation free.

  5. Dynamic contrast-enhanced MRI versus 18F-FDG PET/CT: Which is better in differentiation between malignant and benign solitary pulmonary nodules?

    Science.gov (United States)

    Feng, Feng; Qiang, Fulin; Shen, Aijun; Shi, Donghui; Fu, Aiyan; Li, Haiming; Zhang, Mingzhu; Xia, Ganlin; Cao, Peng

    2018-01-01

    Objective To prospectively compare the discriminative capacity of dynamic contrast enhanced-magnetic resonance imaging (DCE-MRI) with that of 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography/computed tomography (PET/CT) in the differentiation of malignant and benign solitary pulmonary nodules (SPNs). Methods Forty-nine patients with SPNs were included in this prospective study. Thirty-two of the patients had malignant SPNs, while the other 17 had benign SPNs. All these patients underwent DCE-MRI and 18F-FDG PET/CT examinations. The quantitative MRI pharmacokinetic parameters, including the trans-endothelial transfer constant (Ktrans), redistribution rate constant (Kep), and fractional volume (Ve), were calculated using the Extended-Tofts Linear two-compartment model. The 18F-FDG PET/CT parameter, maximum standardized uptake value (SUVmax), was also measured. Spearman’s correlations were calculated between the MRI pharmacokinetic parameters and the SUVmax of each SPN. These parameters were statistically compared between the malignant and benign nodules. Receiver operating characteristic (ROC) analyses were used to compare the diagnostic capability between the DCE-MRI and 18F-FDG PET/CT indexes. Results Positive correlations were found between Ktrans and SUVmax, and between Kep and SUVmax (P0.05). Conclusions DCE-MRI can be used to differentiate between benign and malignant SPNs and has the advantage of being radiation free. PMID:29545716

  6. Differentiation between malignant and benign solitary pulmonary nodules: Use of volume first-pass perfusion and combined with routine computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Shan, Fei, E-mail: shanfeiqz@gmail.com [Department of Radiology, Third Affiliated Hospital of Suzhou University, 185, Juqian Road, Changzhou, Zip Code: 213003 (China); Zhang, Zhiyong, E-mail: zhangzy@fudan.edu.cn [Department of Radiology, Zhongshan Hospital Fudan University, 180, Fenglin Road, Shanghai, Zip Code: 200032 (China); Xing, Wei, E-mail: suzhxingwei@126.com [Department of Radiology, Third Affiliated Hospital of Suzhou University, 185, Juqian Road, Changzhou, Zip Code: 213003 (China); Qiu, Jianguo, E-mail: step9999@sina.com [Department of Radiology, Third Affiliated Hospital of Suzhou University, 185, Juqian Road, Changzhou, Zip Code: 213003 (China); Yang, Shan, E-mail: yang.shan@zs-hospital.sh.cn [Department of Radiology, Zhongshan Hospital Fudan University, 180, Fenglin Road, Shanghai, Zip Code: 200032 (China); Wang, Jian, E-mail: wang.jian@zs-hospital.sh.cn [Department of Radiology, Zhongshan Hospital Fudan University, 180, Fenglin Road, Shanghai, Zip Code: 200032 (China); Jiang, Yaping, E-mail: jiang.yaping@zs-hospital.sh.cn [Department of Radiology, Zhongshan Hospital Fudan University, 180, Fenglin Road, Shanghai, Zip Code: 200032 (China); Chen, Gang, E-mail: chen.gang@zs-hospital.sh.cn [Department of Radiology, Zhongshan Hospital Fudan University, 180, Fenglin Road, Shanghai, Zip Code: 200032 (China)

    2012-11-15

    Purpose: To evaluate the capability of first-pass volume perfusion computed tomography (PCT) for differentiation of solitary pulmonary nodules (SPNs) and to compare that of combination of PCT and routine CT with CT alone for the differentiation. Materials and methods: Our institutional review board approved this study and informed consent was obtained. With nine excluded, 65 consecutive patients having a SPN with histopathologic proof or follow-up underwent a 30 s PCT using the deconvolution model were evaluated. Kruskal-Wallis tests and receiver operating characteristics (ROC) analysis were underwent. Four radiologists assessed nodules independently and retrospectively. Diagnostic capability was compared for CT alone and PCT plus CT. ROC analysis, McNemar test, and weighted kappa statistics were performed. Results: Significant differences were found in parameters between malignant and benign nodules (p < 0.0001 for blood flow, blood volume, and permeability surface area product), SPNs were more likely to be malignant by using threshold values of more than 55 ml/100 g/min, 2.5 ml/100 g, and 10 ml/100 g/min, respectively. PCT plus CT was significantly better in overall sensitivity (93%, p = 0.004) and accuracy (94%, p = 0.003) compared to CT alone, not specificity (96%). Area under the curve for ROC analyses of PCT plus CT was significantly larger than that of CT alone (p = 0.018). Mean weighted kappa for PCT plus CT was 0.715, that for CT alone was 0.447. Conclusion: Volume first-pass PCT can distinguish SPNs. Using PCT plus routine CT may be more sensitive and accurate for differentiating malignant from benign nodules than CT alone and allows more confidence and constancy.

  7. Differentiation between malignant and benign solitary pulmonary nodules: Use of volume first-pass perfusion and combined with routine computed tomography

    International Nuclear Information System (INIS)

    Shan, Fei; Zhang, Zhiyong; Xing, Wei; Qiu, Jianguo; Yang, Shan; Wang, Jian; Jiang, Yaping; Chen, Gang

    2012-01-01

    Purpose: To evaluate the capability of first-pass volume perfusion computed tomography (PCT) for differentiation of solitary pulmonary nodules (SPNs) and to compare that of combination of PCT and routine CT with CT alone for the differentiation. Materials and methods: Our institutional review board approved this study and informed consent was obtained. With nine excluded, 65 consecutive patients having a SPN with histopathologic proof or follow-up underwent a 30 s PCT using the deconvolution model were evaluated. Kruskal–Wallis tests and receiver operating characteristics (ROC) analysis were underwent. Four radiologists assessed nodules independently and retrospectively. Diagnostic capability was compared for CT alone and PCT plus CT. ROC analysis, McNemar test, and weighted kappa statistics were performed. Results: Significant differences were found in parameters between malignant and benign nodules (p < 0.0001 for blood flow, blood volume, and permeability surface area product), SPNs were more likely to be malignant by using threshold values of more than 55 ml/100 g/min, 2.5 ml/100 g, and 10 ml/100 g/min, respectively. PCT plus CT was significantly better in overall sensitivity (93%, p = 0.004) and accuracy (94%, p = 0.003) compared to CT alone, not specificity (96%). Area under the curve for ROC analyses of PCT plus CT was significantly larger than that of CT alone (p = 0.018). Mean weighted kappa for PCT plus CT was 0.715, that for CT alone was 0.447. Conclusion: Volume first-pass PCT can distinguish SPNs. Using PCT plus routine CT may be more sensitive and accurate for differentiating malignant from benign nodules than CT alone and allows more confidence and constancy.

  8. Pulmonary nodule: new concepts of an Old Problem

    International Nuclear Information System (INIS)

    Diederich, S.; Wormanns, D.

    2003-01-01

    In the past, a pulmonary nodule was considered malignant until proven otherwise, usually histologically, which frequently required invasive diagnostic procedures. The nodule was mostly detected on conventional chest radiographs and usually larger than 10 mm. Recently, modern (multi-slice) helical CT detects an increasing number of very small (≤ 10 mm) nodules, which are benign in > 95%. Consequently, the exclusion of malignancy demands different diagnostic procedures, which should be predominantly non-invasive. This article presents the current data as well as imaging techniques for the determination of the nature of pulmonary nodules and suggests concepts for the diagnostic approach to small pulmonary nodules. (orig.) [de

  9. Proton MR spectroscopy in solitary pulmonary nodules: a preliminary study

    International Nuclear Information System (INIS)

    Yang Chunshan; Xiao Xiangsheng; Li Huimin; Liu Shiyuan; Li Chengzhou; Li Shenjiang

    2005-01-01

    Objective: To study the characteristics and the regularities of the metabolites in solitary pulmonary nodules with proton MR spectroscopy, and to investigate the clinical value of MR spectroscopy in differentiating benign from malignant pulmonary nodules. Methods: Sixty-nine patients with solitary pulmonary nodules underwent routine MRI and single-voxel MR spectroscopy using Siemens Vision 1.5 T MR system. MR spectroscopy characteristics and parameters of the metabolites were observed and recorded. Ten pathologic specimens were examined with single-voxel MR spectroscopy. The MR spectroscopy results of the pathologic specimens were compared with those of the solitary pulmonary nodules in vivo. Results: The Cho peak (2.86 ± 1.89) of the malignant nodules was higher than that of the inflammatory (0.87 ± 0.74), tuberculous nodules (0.97 ± 1.09), and hamartoma (0.42 ± 0.53) (P 0.05). Conclusion: MR spectroscopy is reliable in evaluating pulmonary nodules in vivo. The Cho peak, Cho/Cr, and Lac peak of the malignant nodules were higher than those of inflammatory, tuberculous nodules, and hamartoma. MR spectroscopy is helpful in differentiating benign from malignant pulmonary nodules. (authors)

  10. Isolate pulmonary nodule. CT-guided biopsy

    International Nuclear Information System (INIS)

    Bruneton, J.N.; Ettore, F.; Rogopoulos, A.; Geoffray, A.; Balu-Maestro, C.; Le Houcq, M.

    1989-01-01

    Transparietal CT-guided biopsy location can be successfully performed for isolate pulmonary nodules, defined as lesions with a maximal diameter of 3 cm, without any other parenchymal or mediastinal abnormality. A 21 G needle has been used according to an identical protocole in 64 cases (10 benign, 54 malignant). The biopsy was successful in 77.7% of the malignant cases. In relation to the diameter of the nodules, biopsy was successful in 66.7% of the nodules smaller than 2 cm and in 76% of the nodules ranging from 2 to 3 cm. The complications observed were rare (1 case of pneumothorax requiring drainage, 9 cases of pneumothorax without clinical signs and simply followed up, 4 cases of minor hemoptysis requiring no treatment and 5 cases of hematomas smaller than 5 cm on CT) [fr

  11. Improved pulmonary nodule classification utilizing quantitative lung parenchyma features.

    Science.gov (United States)

    Dilger, Samantha K N; Uthoff, Johanna; Judisch, Alexandra; Hammond, Emily; Mott, Sarah L; Smith, Brian J; Newell, John D; Hoffman, Eric A; Sieren, Jessica C

    2015-10-01

    Current computer-aided diagnosis (CAD) models for determining pulmonary nodule malignancy characterize nodule shape, density, and border in computed tomography (CT) data. Analyzing the lung parenchyma surrounding the nodule has been minimally explored. We hypothesize that improved nodule classification is achievable by including features quantified from the surrounding lung tissue. To explore this hypothesis, we have developed expanded quantitative CT feature extraction techniques, including volumetric Laws texture energy measures for the parenchyma and nodule, border descriptors using ray-casting and rubber-band straightening, histogram features characterizing densities, and global lung measurements. Using stepwise forward selection and leave-one-case-out cross-validation, a neural network was used for classification. When applied to 50 nodules (22 malignant and 28 benign) from high-resolution CT scans, 52 features (8 nodule, 39 parenchymal, and 5 global) were statistically significant. Nodule-only features yielded an area under the ROC curve of 0.918 (including nodule size) and 0.872 (excluding nodule size). Performance was improved through inclusion of parenchymal (0.938) and global features (0.932). These results show a trend toward increased performance when the parenchyma is included, coupled with the large number of significant parenchymal features that support our hypothesis: the pulmonary parenchyma is influenced differentially by malignant versus benign nodules, assisting CAD-based nodule characterizations.

  12. [Role of MRI for detection and characterization of pulmonary nodules].

    Science.gov (United States)

    Sommer, G; Koenigkam-Santos, M; Biederer, J; Puderbach, M

    2014-05-01

    Due to physical and technical limitations, magnetic resonance imaging (MRI) has hitherto played only a minor role in image-based diagnostics of the lungs. However, as a consequence of important methodological developments during recent years, MRI has developed into a technically mature and clinically well-proven method for specific pulmonary questions. The purpose of this article is to provide an overview on the currently available sequences and techniques for assessment of pulmonary nodules and analyzes the clinical significance according to the current literature. The main focus is on the detection of lung metastases, the detection of primary pulmonary malignancies in high-risk individuals and the differentiation between pulmonary nodules of benign and malignant character. The MRI technique has a sensitivity of approximately 80 % for detection of malignant pulmonary nodules compared to the reference standard low-dose computed tomography (CT) and is thus somewhat inferior to CT. Advantages of MRI on the other hand are a higher specificity in differentiating malignant and benign pulmonary nodules and the absence of ionizing radiation exposure. A systematic use of MRI as a primary tool for detection and characterization of pulmonary nodules is currently not recommended due to insufficient data. The diagnostic potential of MRI for early detection and staging of malignant pulmonary diseases, however, seems promising. Therefore, further evaluation of MRI as a secondary imaging modality in clinical trials is highly warranted.

  13. Unusual CT findings of a benign metastasizing leiomyoma presenting with multiple cavitary nodules: a case report

    International Nuclear Information System (INIS)

    Ahn, Ji Eun; Do, Kyung Hyun; Chae, Eun Jin; Seo, Joon Beom; Lee, Jin Seong; Song, Koun Sik; Song, Jae Wo; Kim, Kyu Rae; Lim, Tae Hwan

    2007-01-01

    A benign metastasizing leiomyoma is a rare condition that affects women with a history of uterine leiomyoma, usually after a myomectomy or hysterectomy. Typical radiographic findings include well-circumscribed solitary or multiple pulmonary nodules ranging from a few millimeters to several centimeters in diameter and scattered among the normal interstitium. We report a case of a benign metastasizing leiomyoma that manifested with multiple cavitary nodules in a 46-year-old woman with no previous history of a myomectomy or hysterectomy

  14. Unusual CT findings of a benign metastasizing leiomyoma presenting with multiple cavitary nodules: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Ji Eun; Do, Kyung Hyun; Chae, Eun Jin; Seo, Joon Beom; Lee, Jin Seong; Song, Koun Sik; Song, Jae Wo; Kim, Kyu Rae; Lim, Tae Hwan [University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2007-09-15

    A benign metastasizing leiomyoma is a rare condition that affects women with a history of uterine leiomyoma, usually after a myomectomy or hysterectomy. Typical radiographic findings include well-circumscribed solitary or multiple pulmonary nodules ranging from a few millimeters to several centimeters in diameter and scattered among the normal interstitium. We report a case of a benign metastasizing leiomyoma that manifested with multiple cavitary nodules in a 46-year-old woman with no previous history of a myomectomy or hysterectomy.

  15. On the computed tomographic diagnosis of pulmonary nodules

    International Nuclear Information System (INIS)

    Higashi, Yuuichirou

    1988-01-01

    Computed tomography (CT) was used to examine 53 pulmonary nodules which were considered not definitely calcified on plain radiographs or conventional tomograms. An average CT number was calculate for each lesion. For the primary lung cancers, the average CT number was 36 HU with a standard deviation of 6.6 HU, while the benign lesions had the mean CT number of 69 HU, with a standard deviation of 42.8 HU. The mean CT number separating lung malignancies from benign lesions was 78.8 HU. To evaluate the attenuation values within each nodule, iso-CT value map was obtained by using Siemens therapy planning system, MEVAPLAN. Nodules were classified into five categories, Type I to V. All of three nodules classified as Type IV were benign. Iso-CT value map was effective in establishing the benignancy of nodules. The quantitative computed tomographic analysis of pulmonary nodules was evaluated by dual-energy CT. Dual-energy CT has the potential to eliminate the effect of spectral hardening by use of monoenergic images derived from dual-kV data and to separate high CT numbers due to calcium from those due to high density organic material. (author)

  16. Management of solid pulmonary nodules

    International Nuclear Information System (INIS)

    Poschenrieder, F.; Beyer, L.; Stroszczynski, C.; Hamer, O.W.; Rehbock, B.; Diederich, S.; Wormanns, D.

    2014-01-01

    The increasing availability of computed tomography has meant that the number of incidentally detected solitary pulmonary nodules (SPN) has greatly increased in recent years. A reasonable management of these SPN is necessary in order to firstly be able to detect malignant lesions early on and secondly to avoid upsetting the patient unnecessarily or carrying out further stressful diagnostic procedures. This review article shows how the dignity of SPNs can be estimated and based on this how the management can be accomplished taking established guidelines into consideration. (orig.) [de

  17. Fusariosis as solitary pulmonary nodule

    International Nuclear Information System (INIS)

    Moreno, Nelson; Saavedra R, Alfredo; Sanchez Edgar A

    2008-01-01

    Invasive fungal infections are common cause of morbidity and mortality in immunocompromised patients. Of these the most frequents are: aspergillosis and Fusariosis, both grouped under the term Hyalohyphomycosis. One of the organs most commonly affected is the lung.Unfortunately the clinical manifestations as cough, pain and bleeding pleuritic such are none specific. The chest Rx may show since alveolar infiltration, or nodular lesions until cavitaciones. This is the first report on Colombia of a single pulmonary nodule by Fusarium fungi in an immunocompetent patient.

  18. Pulmonary nodule characterization, including computer analysis and quantitative features.

    Science.gov (United States)

    Bartholmai, Brian J; Koo, Chi Wan; Johnson, Geoffrey B; White, Darin B; Raghunath, Sushravya M; Rajagopalan, Srinivasan; Moynagh, Michael R; Lindell, Rebecca M; Hartman, Thomas E

    2015-03-01

    Pulmonary nodules are commonly detected in computed tomography (CT) chest screening of a high-risk population. The specific visual or quantitative features on CT or other modalities can be used to characterize the likelihood that a nodule is benign or malignant. Visual features on CT such as size, attenuation, location, morphology, edge characteristics, and other distinctive "signs" can be highly suggestive of a specific diagnosis and, in general, be used to determine the probability that a specific nodule is benign or malignant. Change in size, attenuation, and morphology on serial follow-up CT, or features on other modalities such as nuclear medicine studies or MRI, can also contribute to the characterization of lung nodules. Imaging analytics can objectively and reproducibly quantify nodule features on CT, nuclear medicine, and magnetic resonance imaging. Some quantitative techniques show great promise in helping to differentiate benign from malignant lesions or to stratify the risk of aggressive versus indolent neoplasm. In this article, we (1) summarize the visual characteristics, descriptors, and signs that may be helpful in management of nodules identified on screening CT, (2) discuss current quantitative and multimodality techniques that aid in the differentiation of nodules, and (3) highlight the power, pitfalls, and limitations of these various techniques.

  19. Diagnosis and management of solitary pulmonary nodules.

    Science.gov (United States)

    Jeong, Yeon Joo; Lee, Kyung Soo; Kwon, O Jung

    2008-12-01

    The advent of computed tomography (CT) screening with or without the help of computer-aided detection systems has increased the detection rate of solitary pulmonary nodules (SPNs), including that of early peripheral lung cancer. Helical dynamic (HD)CT, providing the information on morphologic and hemodynamic characteristics with high specificity and reasonably high accuracy, can be used for the initial assessment of SPNs. (18)F-fluorodeoxyglucose PET/CT is more sensitive at detecting malignancy than HDCT. Therefore, PET/CT may be selectively performed to characterize SPNs when HDCT gives an inconclusive diagnosis. Serial volume measurements are currently the most reliable methods for the tissue characterization of subcentimeter nodules. When malignant nodule is highly suspected for subcentimeter nodules, video-assisted thoracoscopic surgery nodule removal after nodule localization using the pulmonary nodule-marker system may be performed for diagnosis and treatment.

  20. Radio-guided thoracoscopic surgery (RGTS) of small pulmonary nodules.

    Science.gov (United States)

    Ambrogi, Marcello Carlo; Melfi, Franca; Zirafa, Carmelina; Lucchi, Marco; De Liperi, Annalisa; Mariani, Giuliano; Fanucchi, Olivia; Mussi, Alfredo

    2012-04-01

    The demand for adequate tissue sampling to determine individual tumor behavior is increasing the number of lung nodule resections, even when the diagnosis is already recognized. Video-assisted thoracic surgery (VATS) is the procedure of choice for diagnosis and treatment of small pulmonary nodules. Difficulties in localizing smaller and deeper nodules have been approached with different techniques. Herein we report our 13-years' experience with radio-guided thoracoscopic resection. Patients with pulmonary nodules smaller than 1 cm and/or deeper than 1 cm, below the visceral pleura, underwent computed tomography (CT)-guided injection of a solution, composed of 0.2 ml (99)Tc-labeled human serum albumin microspheres and 0.1 ml nonionic contrast, into the nodule. During the VATS procedure, an 11-mm-diameter collimated probe connected to a gamma ray detector was introduced to scan the lung surface. The area of major radioactivity, which matched with the area of the nodule, was resected. From 1997 to 2009, 573 patients underwent thoracoscopic resection of small pulmonary nodules, 211 with the radio-guided technique. There were 159 men and 52 women, with an average age of 60.6 years (range = 12-83). The mean duration of the surgical procedure was 41 min (range = 20-100). The procedure was successful in 208/211 cases. Three patients (0.5%) required conversion to a minithoracotomy. The mean length of pleural drainage and hospital stay was 2.3 and 3.7 days, respectively. Histological examination showed 98 benign lesions and 113 malignant lesions (61 metastases and 52 primary lung cancers). This study confirms that radio-guided localization of small pulmonary nodules is a feasible, safe, and quick procedure, with a high rate of success. The spread of the sentinel lymph node technique has increased the availability of technology required for RGTS.

  1. Thermal Ablation for Benign Thyroid Nodules: Radiofrequency and Laser

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Jung Hwan; Lee, Jeong Hyun [University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of); Valcavi, Roberto [Endocrinology Division and Thyroid Disease Center, Arcispedale Santa Maria Nuova, Reggio Emilia (Italy); Pacella, Claudio M. [Diagnostic Imaging and Interventional Radiology Department, Ospedale Regina Apostolorum, Albano Laziale-Rome (IT); Rhim, Hyun Chul [Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Na, Dong Kyu [Human Medical Imaging and Intervention Center, Seoul (Korea, Republic of)

    2011-10-15

    Although ethanol ablation has been successfully used to treat cystic thyroid nodules, this procedure is less effective when the thyroid nodules are solid. Radiofrequency (RF) ablation, a newer procedure used to treat malignant liver tumors, has been valuable in the treatment of benign thyroid nodules regardless of the extent of the solid component. This article reviews the basic physics, techniques, applications, results, and complications of thyroid RF ablation, in comparison to laser ablation.

  2. Pulmonary nodules secondary to total parenteral alimentation

    International Nuclear Information System (INIS)

    Landry, B.A.; Melhem, R.E.

    1989-01-01

    A seven-year-old male, who had a retroperitoneal alveolar rhabdomyosarcoma and was on total parenteral alimentation (TPN) developed muliple pulmonary nodules, indistinguishable from metastases. These proved to be multiple lipid emboli on open biopsy. (orig.)

  3. Computed tomographic diagnosis of pulmonary nodules

    International Nuclear Information System (INIS)

    Onoue, Masataka

    1986-01-01

    One hundred and fifty-two pulmonary nodules (PNs) were examined by thin-section computed tomography (CT) and conventional tomography (tomography). In this study, 109 PNs were analyzed to assess tissue density by calculating the representative CT number (RCT no.) from a computer printout. For the primary malignancies, the mean RCT no. was 72 HU, with a standard deviation (SD) of 21 HU, and for metastases, it was 66 ± 19 HU. The RCT no. separating primary malignancy from benign lesions was 157 HU, the one including metastasis was 183 HU. In addition, dual-energy CT scan was performed to evaluate capability of diagnosing calcification in 35 PNs. Dual-energy CT scan had increased the reliability of CT diagnosis for PNs with RCT no. between 100 HU and 300 HU. The descriptive criteria of CT and tomography for 127 PNs were analyzed and statistical diagnoses by CT and tomography were compared with the results of their final diagnoses. CT and tomography had domonstrated similar sensitivities in the evaluation of primary malignancies; 86 % in CT and 90 % in tomography, and the same sensitivities (86 %) in diagnosing metastases. In evaluating benign PNs, CT was superior to tomography with capability to detect minimal calcification and fat density; the specificity was 80 % with CT, and 52 % with tomography (p < 0.025). Overall accuracy in the diagnosis for PNs was 82 % with CT, and 73 % with tomography, which was not different statistically. It can be concluded that CT is a reliable examination in the evaluation of PNs, and there is an advantage to the use of CT over tomography in diagnosing benign lesions. (author)

  4. Percutaneous radiofrequency ablation for benign nodules of the thyroid gland

    International Nuclear Information System (INIS)

    Baek, Jung Hwan; Jeong, Hyun Jo; Kim, Yoon Suk; Kwak, Min Sook; Chang, Sun Hee; Rhim, Hyun Chul

    2005-01-01

    We wanted to evaluate the efficacy and safety of using ultrasound guided percutaneous radiofrequency ablation for the benign nodules of the thyroid gland. We studied 148 patients with benign thyroid nodules (200 total nodules) that were confirmed histopathologically, and we performed ultrasound guided radiofrequency ablation. The radiofrequency ablation was done 1 to 5 times per one nodule, and follow-up ultrasonography was performed one to nineteen months after the ablation procedures. The physical changes and the decrease of volume of the nodules were evaluated, and the complications related to radiofrequency ablation were observed. The mean initial nodule volume was 0.01-95.61 ml (mean; 6.83 ± SD of 10.63 ml) and the nodule volume after radiofrequency ablation was decreased to 0.00-46.56 ml (mean; 1.83 ± SD of 4.69 ml). The mean volume reduction rate was 73.2%. Reduction of more than 50% was noted in 90% of all cases. For 180 nodules (90%), the decrease was 50% or more, in 20 nodules (10%), the decrease was 49% or less. On gray-scale ultrasonogram obtained after ablation, the echogenicity of the nodules changed to darker, and on the doppler-sonogram, the vascular flow within the nodules disappeared in all cases. Most patients complained pain during or right after the procedure, but the pain was transient and subsided after medication. Two patients developed hoarseness that was improved in 1 week and 2 months, respectively. Sonoguided percutaneous radiofrequency ablation can be one of the treatments for benign nodules of the thyroid gland

  5. Thyroid carcinoma masquerading as a solitary benign hyperfunctioning nodule

    Energy Technology Data Exchange (ETDEWEB)

    Sandler, M.P.; Fellmeth, B.; Salhany, K.E.; Patton, J.A.

    1988-06-01

    Focal hot nodules on iodine thyroid images are associated with an exceedingly low incidence of malignancy. Most previously reported hot carcinomas represent the coexistence of small malignancies in or adjacent to a benign hot lesion. Described here is a 3-cm papillary carcinoma that fulfilled the criteria for benignancy on Tc-99m and I-123 imaging. Coincidental carcinoma within a benign lesion was excluded by detailed scintigraphic-pathologic correlation of the tumor. The implications of this case on the management of the solitary hot nodule are discussed and the literature reviewed.

  6. Thyroid carcinoma masquerading as a solitary benign hyperfunctioning nodule

    International Nuclear Information System (INIS)

    Sandler, M.P.; Fellmeth, B.; Salhany, K.E.; Patton, J.A.

    1988-01-01

    Focal hot nodules on iodine thyroid images are associated with an exceedingly low incidence of malignancy. Most previously reported hot carcinomas represent the coexistence of small malignancies in or adjacent to a benign hot lesion. Described here is a 3-cm papillary carcinoma that fulfilled the criteria for benignancy on Tc-99m and I-123 imaging. Coincidental carcinoma within a benign lesion was excluded by detailed scintigraphic-pathologic correlation of the tumor. The implications of this case on the management of the solitary hot nodule are discussed and the literature reviewed

  7. Histoplasmosis presenting with solitary pulmonary nodule: Two ...

    African Journals Online (AJOL)

    Pulmonary histoplasmosis is a granulomatous disease, whose diagnosis is not always easy, as it may simulate metastatic lesions due to similar radiographic findings. We herein report two cases of histoplasmosis with solitary pulmonary nodule in asymptomatic patients with histories of cancer surgeries, whose diagnoses ...

  8. Effects of Different Reconstruction Parameters on CT Volumetric Measurement 
of Pulmonary Nodules

    Directory of Open Access Journals (Sweden)

    Rongrong YANG

    2012-02-01

    Full Text Available Background and objective It has been proven that volumetric measurements could detect subtle changes in small pulmonary nodules in serial CT scans, and thus may play an important role in the follow-up of indeterminate pulmonary nodules and in differentiating malignant nodules from benign nodules. The current study aims to evaluate the effects of different reconstruction parameters on the volumetric measurements of pulmonary nodules in chest CT scans. Methods Thirty subjects who underwent chest CT scan because of indeterminate pulmonary nodules in General Hospital of Tianjin Medical University from December 2009 to August 2011 were retrospectively analyzed. A total of 52 pulmonary nodules were included, and all CT data were reconstructed using three reconstruction algorithms and three slice thicknesses. The volumetric measurements of the nodules were performed using the advanced lung analysis (ALA software. The effects of the reconstruction algorithms, slice thicknesses, and nodule diameters on the volumetric measurements were assessed using the multivariate analysis of variance for repeated measures, the correlation analysis, and the Bland-Altman method. Results The reconstruction algorithms (F=13.6, P<0.001 and slice thicknesses (F=4.4, P=0.02 had significant effects on the measured volume of pulmonary nodules. In addition, the coefficients of variation of nine measurements were inversely related with nodule diameter (r=-0.814, P<0.001. The volume measured at the 2.5 mm slice thickness had poor agreement with the volumes measured at 1.25 mm and 0.625 mm, respectively. Moreover, the best agreement was achieved between the slice thicknesses of 1.25 mm and 0.625 mm using the bone algorithm. Conclusion Reconstruction algorithms and slice thicknesses have significant impacts on the volumetric measurements of lung nodules, especially for the small nodules. Therefore, the reconstruction setting in serial CT scans should be consistent in the follow

  9. Benign and malignant thyroid nodules after neck irradiation

    International Nuclear Information System (INIS)

    Fjaelling, M.T.; Tisell, L.E.; Carlsson, S.; Hansson, G.; Lundberg, L.M.; Oden, A.

    1986-01-01

    A total of 444 persons were examined for the presence of thyroid nodules on average of 43 years after having been treated with x-rays for cervical tuberculous adenitis. Of this total, 101 subjects had undergone surgery for thyroid nodules: 25 for carcinoma (6%) and 76 for benign nodules (17%). Carcinoma occurred with the same frequency in multinodular and uninodular glands. Because of the uneven age distribution in the current series, it could not be decided whether there was a higher susceptibility of the young thyroid to the induction of thyroid carcinoma or benign nodules. The dosage range for the whole series was 0.40 to 50.90 Gy (40-5090 rad). There was a positive correlation between the absorbed radiation dose and the probability of developing benign and malignant thyroid nodules, even after doses of 20 Gy or more. The risk of developing thyroid carcinoma was equal for men and women, while the female-to-male ratio for benign nodules was 2.9:1, indicating that risk factors associated with females are of less importance in irradiated than in nonirradiated populations. The median latency for carcinoma was 40 years, suggesting that the increased risk of thyroid carcinoma after irradiation remains for the rest of the patient's life

  10. Multilevel binomial logistic prediction model for malignant pulmonary nodules based on texture features of CT image

    International Nuclear Information System (INIS)

    Wang Huan; Guo Xiuhua; Jia Zhongwei; Li Hongkai; Liang Zhigang; Li Kuncheng; He Qian

    2010-01-01

    Purpose: To introduce multilevel binomial logistic prediction model-based computer-aided diagnostic (CAD) method of small solitary pulmonary nodules (SPNs) diagnosis by combining patient and image characteristics by textural features of CT image. Materials and methods: Describe fourteen gray level co-occurrence matrix textural features obtained from 2171 benign and malignant small solitary pulmonary nodules, which belongs to 185 patients. Multilevel binomial logistic model is applied to gain these initial insights. Results: Five texture features, including Inertia, Entropy, Correlation, Difference-mean, Sum-Entropy, and age of patients own aggregating character on patient-level, which are statistically different (P < 0.05) between benign and malignant small solitary pulmonary nodules. Conclusion: Some gray level co-occurrence matrix textural features are efficiently descriptive features of CT image of small solitary pulmonary nodules, which can profit diagnosis of earlier period lung cancer if combined patient-level characteristics to some extent.

  11. Solitary pulmonary nodule by pulmonary hematoma under warfarin therapy

    International Nuclear Information System (INIS)

    Scheppach, W.; Kulke, H.; Liebau, G.; Braun, H.; Wuerzburg Univ.

    1983-01-01

    Pulmonary hematoma is a rare cause of a pulmonary nodule. Mostly it results from penetrating or blunt chest injuries. The case of a patient is reported, whose chest X-ray showed a pulmonary nodule suspected of malignancy. This patient was maintained permanently on anticoagulants (warfarin derivates) after cardiac valve replacement with a prosthesis. A definite diagnosis could not be established by non-invasive methods. A needle biopsy of the lung was impracticable because of the location of the pulmonary lesion; an exploratory thoracotomy could not be carried out due to a general indication of nonoperability. Control examinations showed that the pulmonary nodule had vanished completely within four months. In consideration of the patient's clinical situation it can be concluded that the pulmonary lesion was caused by a hematoma of the lung. (orig.) [de

  12. Solitary pulmonary nodule by pulmonary hematoma under warfarin therapy

    Energy Technology Data Exchange (ETDEWEB)

    Scheppach, W.; Kulke, H.; Liebau, G.; Braun, H.

    1983-06-01

    Pulmonary hematoma is a rare cause of a pulmonary nodule. Mostly it results from penetrating or blunt chest injuries. The case of a patient is reported, whose chest X-ray showed a pulmonary nodule suspected of malignancy. This patient was maintained permanently on anticoagulants (warfarin derivates) after cardiac valve replacement with a prosthesis. A definite diagnosis could not be established by non-invasive methods. A needle biopsy of the lung was impracticable because of the location of the pulmonary lesion; an exploratory thoracotomy could not be carried out due to a general indication of nonoperability. Control examinations showed that the pulmonary nodule had vanished completely within four months. In consideration of the patient's clinical situation it can be concluded that the pulmonary lesion was caused by a hematoma of the lung.

  13. Usefulness of CT-guided automatic needle biopsy of solitary pulmonary nodule smaller than 15 mm

    International Nuclear Information System (INIS)

    Jin, Gong Yong; Lim, Yeong Su

    2004-01-01

    To evaluate the usefulness of the CT-guided percutaneous lung biopsy for the solitary pulmonary nodules smaller than 15 mm in diameter. Between April 2002 and May 2003, we evaluated twenty-five patients (11 men, 14 women, mean ages: 52.5 years) who had solitary pulmonary nodules, which we could not discriminate as being benign or malignant on the CT findings. All the subjects had CT-guided percutaenous cutting needle biopsy (PCNB) performed on them at our institution. A definitive diagnosis of benignity or malignancy was established to retrospectively analyze the patient's records. We evaluated the accuracy, sensitivity, specificity and complications of PCNB for the definitive diagnosis of benignity or malignancy. The sensitivity and specificity of PCNB were determined using the Chi-square test, and the correlations with pneumothorax and emphysema after biopsy were analyzed using Spearman's rank correlation coefficient. In two nodules of the twenty-five nodules, no definitive diagnosis could be established. Of the remaining twenty-three nodules, 7 (30.4%) were malignant and 16 (69.6%) were benign. Twenty (87%) of the twenty-three definitively diagnosed nodules were correctly diagnosed with PCNB. Of the twenty nodules, 6 (30%) were malignant and 14 (70%) were benign. The sensitivity and specificity of the malignant nodules were 85.7% (6/7) and 100% (16/16), respectively. The sensitivity and specificity of the benign nodules were 87.5% (14/16) and 85.7% (6/7), respectively. Post-biopsy complication occurred in nine patients (36%): Hemoptysis (n=4, 16%) and pneumothorax (n=5, 20%). However, there was not a statistical significance between pneumothorax and emphysema after biopsy (r=0.3, p=0.15). When CT-guided percutaneous lung biopsy of the solitary pulmonary nodules smaller than 15 mm in diameter was performed without an on-site cytopathologist, we know that PCNB can yield high diagnostic accuracy and very few complications

  14. Ultrasound assistance in differentiating malignant thyroid nodules from benign ones

    International Nuclear Information System (INIS)

    Zahir, S.T.; Sefidrokh, S.; Heidari, F.; Vakili, M.; Ghaneei, A.

    2017-01-01

    The search is ongoing for simple, effective ways to identify and differentiate thyroid nodules in order to avoid invasive procedures. This study aims to perform an ultrasound assessment of clinically suspected patients with malignant nodules, to perform a fine needle biopsy on them, and to compare the results obtained. Methods: In total, 135 patients with thyroid nodules suspected to be malignant in the ultrasound underwent ultrasound-guided fine needle biopsies. The patients' gender, age, ultrasound views (echogenicity, shape, and calcification type), nodule size, number of nodules, and needle biopsy results were retrospectively evaluated. Results: Of the 135 patients, 117 (86.7 percent) were female and 18 (13.3 percent) were male. In terms of age, 67 (49.16 percent) were younger than 40 and the rest were older. According to the Chi-square test, a significant relationship was found between the type of nodule and calcification found in the ultrasound views (p=0.001). The nodule type was not significantly related to gender (p=0.563) or to the number of nodules (p=0.128); however, there was a significant relationship between nodule size and type (p=0.001). Ultrasound specificity, sensitivity, positive and negative predictive values, and accuracy for differentiating benign from malignant nodules were 93.2 percent, 93.8 percent, 81.1 percent, 98 percent, and 93.3 percent, respectively. Conclusions: Ultrasound views (comet tail artefact and linear echogenic foci) were better predictors of benign nodules than of malignant ones, while round, echogenic foci, brighter and larger than typical micro-calcifications without any visible echoes and multiple punctuate round echogenic foci were better predicted malignancy. (author)

  15. Evaluation of percutaneous ethanol injections in benign thyroid nodules.

    Science.gov (United States)

    Perez, Camila Luhm Silva; Fighera, Tayane Muniz; Miasaki, Fabiola; Mesa Junior, Cleo Otaviano; Paz Filho, Gilberto Jorge da; Graf, Hans; Carvalho, Gisah Amaral de

    2014-12-01

    The objective of this study was to evaluate the efficacy and safety of percutaneous ethanol injection (PEI) in the treatment of benign thyroid nodules. We evaluated 120 patients with benign thyroid nodules. Patients underwent evaluation of serum TSH and free T4, cervical ultrasound, and thyroid scintigraphy (in those with suppressed TSH levels). The application of sterile ethanol 99% was guided by ultrasound, with the injected volume amounting to one-third of the nodule volume. Response was considered complete (reduction of 90%); partial (reduction between 50 and 90%); or none (reduction of nodules were evaluated for normalization of TSH levels. Among the nodules studied, 30.8% were solid, 56.7% were mixed, 12.5% were cystic, and 21.6% were hyperfunctioning. The initial volume of the treated nodules ranged from 0.9 to 74.8 mL (mean 13.1 ± 12.4 mL). We performed 1-8 sessions of PEI, applying an average of 6.2 mL of ethanol for patient. After 2 years of follow-up, 17% of patients achieved a complete response (94% reduction); 53%, a partial response (70% reduction); and 30%, no response. A reduction in the volume of autonomous nodules was noted in 70% of cases, and 54% had a normalized value of TSH. The main side effect is local pain, lasting less than 24 hours in most cases. This study showed that PEI is a safe and effective procedure for treatment of benign, solid or mixed thyroid nodules. Most cases resulted in significant reduction in nodule volume, with normalization of thyroid function.

  16. Proposal to utilize simplified Swensen protocol in diagnosis of isolated pulmonary nodule

    Energy Technology Data Exchange (ETDEWEB)

    Ribeiro, Sergio Marrone [Dept. of Tropical Diseases and Diagnostic Imaging, Botucatu Medical School, Univ. Estadual Paulista, Botucatu, Sao Paulo (Brazil)], e-mail: sribeiro@fmb.unesp.br; Ruiz, Raul Lopes; Cataneo, Daniele Cristina; Cataneo, Antonio Jose Maria [Dept. of Surgery, Botucatu Medical School, Univ. Estadual Paulista, Botucatu, Sao Paulo (Brazil); Yoo, Hugo Hyung Bok [Dept. of Internal Medicine, Botucatu Medical School, Univ. Estadual Paulista, Botucatu, Sao Paulo (Brazil)

    2013-09-15

    Background: The problem of diagnosing whether a solitary pulmonary nodule is benign or malignant is even greater in developing countries due to a higher prevalence of infectious diseases. These infections generate a large number of patients who are generally asymptomatic and with a pulmonary nodule that cannot be accurately defined as having benign or malignant etiology. Purpose: To verify the percentages of benign versus malignant non-calcified nodules, the length of time after contrast agent injection is spiral computed tomography (CT) most sensitive and specific, and whether three postcontrast phases are necessary. Material and Methods: We studied 23 patients with solitary pulmonary nodules identified on chest radiographs or CT. Spiral scans were obtained with Swensen protocol, but at 3, 4, and 5 min after contrast injection onset. Nodules were classified as benign or malignant by histopathological examination or by an absence or presence of growth after 2 years of follow-up CT. Results: Of the 23 patients studied, 18 (78.2%) showed a final diagnosis of benign and five (21.7%) malignant nodules. Despite the small sample size, we obtained results similar to those of Swensen et al., with 80.0% sensitivity, 55.5% specificity, and 60.8% accuracy. Four minutes gave the greatest mean enhancement in both malignant and benign lesions. Conclusion: Small non-calcified benign nodules were much more frequent than malignant nodules. The best time for dynamic contrast-enhanced CT density analysis was 4 min postcontrast. As well as saving time and money, this simplified Swensen protocol with only precontrast and 4 min postcontrast phases also reduces patient exposure to ionizing radiation.

  17. Proposal to utilize simplified Swensen protocol in diagnosis of isolated pulmonary nodule

    International Nuclear Information System (INIS)

    Ribeiro, Sergio Marrone; Ruiz, Raul Lopes; Cataneo, Daniele Cristina; Cataneo, Antonio Jose Maria; Yoo, Hugo Hyung Bok

    2013-01-01

    Background: The problem of diagnosing whether a solitary pulmonary nodule is benign or malignant is even greater in developing countries due to a higher prevalence of infectious diseases. These infections generate a large number of patients who are generally asymptomatic and with a pulmonary nodule that cannot be accurately defined as having benign or malignant etiology. Purpose: To verify the percentages of benign versus malignant non-calcified nodules, the length of time after contrast agent injection is spiral computed tomography (CT) most sensitive and specific, and whether three postcontrast phases are necessary. Material and Methods: We studied 23 patients with solitary pulmonary nodules identified on chest radiographs or CT. Spiral scans were obtained with Swensen protocol, but at 3, 4, and 5 min after contrast injection onset. Nodules were classified as benign or malignant by histopathological examination or by an absence or presence of growth after 2 years of follow-up CT. Results: Of the 23 patients studied, 18 (78.2%) showed a final diagnosis of benign and five (21.7%) malignant nodules. Despite the small sample size, we obtained results similar to those of Swensen et al., with 80.0% sensitivity, 55.5% specificity, and 60.8% accuracy. Four minutes gave the greatest mean enhancement in both malignant and benign lesions. Conclusion: Small non-calcified benign nodules were much more frequent than malignant nodules. The best time for dynamic contrast-enhanced CT density analysis was 4 min postcontrast. As well as saving time and money, this simplified Swensen protocol with only precontrast and 4 min postcontrast phases also reduces patient exposure to ionizing radiation

  18. Clinical significance of pulmonary nodules detected on abdominal CT in pediatric patients

    International Nuclear Information System (INIS)

    Breen, Micheal; Lee, Edward Y.; Zurakowski, David

    2015-01-01

    The clinical significance of a pulmonary nodule that is detected incidentally on CT studies in children is unknown. In addition, there is limited information regarding the management of incidentally detected pulmonary nodules discovered on abdominal CT studies in children. The purpose of this study was to investigate the clinical significance of incidental pulmonary nodules detected on abdominal CT studies in children. This was a retrospective study performed following institutional review board approval. Abdominal CT reports in patients younger than 18 years of age from July 2004 to June 2011 were reviewed for the terms ''nodule,'' ''nodular'' or ''mass'' in reference to the lung bases. The study population included those pediatric patients in whom pulmonary nodules were initially detected on abdominal CT studies. The largest pulmonary nodules detected on CT studies were evaluated for their features (size, shape, margin, attenuation, location, and presence of calcification and cavitation). Follow-up CT studies and clinical records were reviewed for demographic information, history of underlying malignancies and the clinical outcome of the incidental pulmonary nodules. Comparison of malignant versus benign pulmonary nodules was performed with respect to the size of the nodule, imaging features on CT, and patient history of malignancy using the Student's t-test and Fisher exact test. Youden J-index in receiver operating characteristic (ROC) analysis was used to determine the optimal cut-off size for suggesting a high risk of malignancy of incidentally detected pulmonary nodules. Pulmonary nodules meeting inclusion criteria were detected in 62 (1.2%) of 5,234 patients. The mean age of patients with nodules was 11.2 years (range: 5 months-18 years). Thirty-one patients (50%) had follow-up CT studies and two of these patients (6%) were subsequently found to have malignant pulmonary nodules. Both of these

  19. Clinical significance of pulmonary nodules detected on abdominal CT in pediatric patients

    Energy Technology Data Exchange (ETDEWEB)

    Breen, Micheal; Lee, Edward Y. [Boston Children' s Hospital and Harvard Medical School, Department of Radiology, Boston, MA (United States); Zurakowski, David [Boston Children' s Hospital and Harvard Medical School, Departments of Anesthesiology and Surgery, Boston, MA (United States)

    2015-11-15

    The clinical significance of a pulmonary nodule that is detected incidentally on CT studies in children is unknown. In addition, there is limited information regarding the management of incidentally detected pulmonary nodules discovered on abdominal CT studies in children. The purpose of this study was to investigate the clinical significance of incidental pulmonary nodules detected on abdominal CT studies in children. This was a retrospective study performed following institutional review board approval. Abdominal CT reports in patients younger than 18 years of age from July 2004 to June 2011 were reviewed for the terms ''nodule,'' ''nodular'' or ''mass'' in reference to the lung bases. The study population included those pediatric patients in whom pulmonary nodules were initially detected on abdominal CT studies. The largest pulmonary nodules detected on CT studies were evaluated for their features (size, shape, margin, attenuation, location, and presence of calcification and cavitation). Follow-up CT studies and clinical records were reviewed for demographic information, history of underlying malignancies and the clinical outcome of the incidental pulmonary nodules. Comparison of malignant versus benign pulmonary nodules was performed with respect to the size of the nodule, imaging features on CT, and patient history of malignancy using the Student's t-test and Fisher exact test. Youden J-index in receiver operating characteristic (ROC) analysis was used to determine the optimal cut-off size for suggesting a high risk of malignancy of incidentally detected pulmonary nodules. Pulmonary nodules meeting inclusion criteria were detected in 62 (1.2%) of 5,234 patients. The mean age of patients with nodules was 11.2 years (range: 5 months-18 years). Thirty-one patients (50%) had follow-up CT studies and two of these patients (6%) were subsequently found to have malignant pulmonary nodules. Both of these

  20. Solitary pulmonary nodule and {sup 18}F-FDG PET/CT. Part 1: epidemiology, morphological evaluation and cancer probability

    Energy Technology Data Exchange (ETDEWEB)

    Mosmann, Marcos Pretto; Borba, Marcelle Alves; Macedo, Francisco Pires Negromonte; Liguori, Adriano de Araujo Lima; Villarim Neto, Arthur, E-mail: mosmann@gmail.com [Liga Norte Riograndense Contra o Cancer, Natal, RN (Brazil); Lima, Kenio Costa de [Universidade Federal do Rio Grande do Norte (UFRN), Natal, RN (Brazil). Programa de Pos-Graduacao em Saude Coletiva

    2016-01-15

    Solitary pulmonary nodule corresponds to a common radiographic finding, which is frequently detected incidentally. The investigation of this entity remains complex, since characteristics of benign and malignant processes overlap in the differential diagnosis. Currently, many strategies are available to evaluate solitary pulmonary nodules with the main objective of characterizing benign lesions as best as possible, while avoiding to expose patients to the risks inherent to invasive methods, besides correctly detecting cases of lung cancer so as the potential curative treatment is not delayed. This first part of the study focuses on the epidemiology, the morphological evaluation and the methods to determine the likelihood of cancer in cases of indeterminate solitary pulmonary nodule. (author)

  1. Quantitation of pulmonary nodule's border structure by means of Fourier transform by using chest X-ray CT images

    International Nuclear Information System (INIS)

    Shikata, Hidenori; Masuyama, Hiroshi; Kido, Shoji

    1998-01-01

    In order to evaluate quantitatively the border structure of pulmonary nodules by using chest X-ray CT images, we investigated whether the sum of high-frequency elements of the power spectrum in a Fourier-transformed nodule's contour line becomes a valuable measure of the border structure of pulmonary nodules. We expect that this measure clearly reflects the radiologic characteristics of a nodule, that is, the contour line is clear or unclear in benign or malignant nodules, respectively. We evaluated and analyzed images statistically for 31 patients (15 benign, 16 malignant), and we were able to recognize a measurable difference between the benign and malignant cases. We conclude that we can evaluate the border structure of a nodule by our proposed measure, and that this measure is valuable for quantitative differential diagnosis. (author)

  2. Chinese herbal medicines for benign thyroid nodules in adults.

    Science.gov (United States)

    Wu, Wenxun; Yin, Detao; Yang, Weimin; Kan, Quancheng; Liu, Zhangsuo; Ren, Xiaoyan; Zhai, Chenguang; Zhang, Shengjun

    2014-03-04

    A thyroid nodule is a discrete lesion within the thyroid gland that might be palpable and is ultrasonographically distinct from the surrounding thyroid parenchyma. Thyroid nodules are more common as age increases and occur more frequently in women. Benign thyroid nodules often cause pressure symptoms and cosmetic complaints. In China and many other countries, doctors use Chinese herbal medicines (CHM) to treat thyroid nodules. To assess the effects of Chinese herbal medicines in the treatment of benign thyroid nodules in adults. Review authors searched the following electronic databases: The Cochrane Library, MEDLINE, EMBASE, the Chinese Biomedical Literature Database (CBM), the China National Knowledge Infrastructure (CNKI), VIP information (a Chinese database), WANFANG Data (a Chinese database), the Chinese Conference Papers Database and the Chinese Dissertation Database (all searched up to April 2013). Randomised controlled trials comparing CHM or CHM plus levothyroxine versus levothyroxine, placebo or no treatment in adults with benign thyroid nodules. Two review authors independently extracted data, assessed studies for risk of bias and evaluated overall study quality according to GRADE (Grading of Recommendations Assessment, Development and Evaluation), with differences resolved by consensus. We included one randomised trial involving 152 participants with a randomisation ratio of 2:1 (CHM vs no treatment). The trial applied adequate sequence generation; however, allocation concealment was unclear. Duration of treatment was three months, and follow-up six months. Our a priori defined outcomes of interest (i.e. nodule volume reduction ≥ 50%; pressure symptoms, cosmetic complaints or both; health-related quality of life; all-cause mortality; cancer occurrence; changes in number and size of thyroid nodules; changes in thyroid volume; and socioeconomic effects) were not investigated in the included study. Thyrotropin (TSH), thyroxine (T4) and tri

  3. Percutaneous laser ablation of benign and malignant thyroid nodules.

    Science.gov (United States)

    Papini, Enrico; Bizzarri, Giancarlo; Pacella, Claudio M

    2008-10-01

    Percutaneous image-guided procedures, largely based on thermal ablation, are at present under investigation for achieving a nonsurgical targeted cytoreduction in benign and malignant thyroid lesions. In several uncontrolled clinical trials and in two randomized clinical trials, laser ablation has demonstrated a good efficacy and safety for the shrinkage of benign cold thyroid nodules. In hyperfunctioning nodules, laser ablation induced a nearly 50% volume reduction with a variable frequency of normalization of thyroid-stimulating hormone levels. Laser ablation has been tested for the palliative treatment of poorly differentiated thyroid carcinomas, local recurrences or distant metastases. Laser ablation therapy is indicated for the shrinkage of benign cold nodules in patients with local pressure symptoms who are at high surgical risk. The treatment should be performed only by well trained operators and after a careful cytological evaluation. Laser ablation does not seem to be consistently effective in the long-term control of hyperfunctioning thyroid nodules and is not an alternative treatment to 131I therapy. Laser ablation may be considered for the cytoreduction of tumor tissue prior to external radiation therapy or chemotherapy of local or distant recurrences of thyroid malignancy that are not amenable to surgical or radioiodine treatment.

  4. Deep learning aided decision support for pulmonary nodules diagnosing: a review.

    Science.gov (United States)

    Yang, Yixin; Feng, Xiaoyi; Chi, Wenhao; Li, Zhengyang; Duan, Wenzhe; Liu, Haiping; Liang, Wenhua; Wang, Wei; Chen, Ping; He, Jianxing; Liu, Bo

    2018-04-01

    Deep learning techniques have recently emerged as promising decision supporting approaches to automatically analyze medical images for different clinical diagnosing purposes. Diagnosing of pulmonary nodules by using computer-assisted diagnosing has received considerable theoretical, computational, and empirical research work, and considerable methods have been developed for detection and classification of pulmonary nodules on different formats of images including chest radiographs, computed tomography (CT), and positron emission tomography in the past five decades. The recent remarkable and significant progress in deep learning for pulmonary nodules achieved in both academia and the industry has demonstrated that deep learning techniques seem to be promising alternative decision support schemes to effectively tackle the central issues in pulmonary nodules diagnosing, including feature extraction, nodule detection, false-positive reduction, and benign-malignant classification for the huge volume of chest scan data. The main goal of this investigation is to provide a comprehensive state-of-the-art review of the deep learning aided decision support for pulmonary nodules diagnosing. As far as the authors know, this is the first time that a review is devoted exclusively to deep learning techniques for pulmonary nodules diagnosing.

  5. Computer-aided diagnosis and volumetry of pulmonary nodules: current concepts and future perspectives

    International Nuclear Information System (INIS)

    Marten, K.; Rummeny, E.J.; Engelke, C.

    2005-01-01

    For computer-aided detection (CAD) and volumetry of small pulmonary nodules, a number of algorithms have been developed for multislice CT data sets in recent years, with the goal of improving the diagnostic work-up and the follow-up of findings. Recent data show that the detection of small lesions may improve with CAD, suggesting that especially experienced readers may benefit from using CAD systems. This has lead to the recommendation of CAD as a replacement of the second reader in clinical practice. Furthermore, computer-aided volumetry of pulmonary nodules allows a precise determination of nodular growth rates as a prerequisite for a better classification of nodules as benign or malignant. In this article, we review recent developments of CAD and volumetry tools for pulmonary nodules, and address open questions regarding the use of these software tools in clinical routine. (orig.)

  6. [The clinical characteristics of pulmonary benign metastasizing leiomyoma].

    Science.gov (United States)

    Wang, H P; Shi, J H; Zhang, L

    2017-07-01

    Objective: Pulmonary benign metastasizing leiomyoma (PBML) is a rare entity that leiomyoma of uterus metastasized to the lung. The clinical characteristics of this rare disease were analyzed in this article. Methods: The detailed clinical records of 7 patients diagnosed as PBML at Peking Union Medical College Hospital between January 2001 and June 2015 were reviewed. Results: All patients were women with median age of 44 years (range 28-62). Symptoms included dyspnea (2/7), chest pain (1/7), cyanosis (1/7), cough (1/7) and bloody sputum (1/7), while 4/7 cases were asymptomatic. Six patients had the past-history of leiomyoma of uterus 20 months to 14 years ago among whom 5 patients received hysterectomy. Chest CT showed bilateral, random-distributed multiple round solid nodules, or diffuse-distributed miliary nodules, or single solid nodule, even some small cavities. Extra-pulmonary metastasis was found in left superclavicular lymph node (1 case) and right heart (1 case). Histological tissues were obtained by video-assisted thoracic surgery lung biopsy (4/7), mass resection on tricuspid valve (1/7), transbronchil lung biopsy (1/7), and CT-guided percutaneous lung biopsy (1/7). Pathology showed an interlacing pattern by spindle cells having elongated nuclei without cellular atypia. Ki-67 index was less than 1%. Molecules such as smooth muscle antibody, estrogen receptor (ER) and progestrone receptor (PR) were positive in immunohistochemistry staining. Neither letrozole nor zoladex was effective. Two patients responded to bilateral adnexectomy, presenting as shrunk nodules. No relapsed disease was seen in one patient with single nodule after resection. There was only one patient with disease-related mortality, whose chest CT showed milliary nodules. Conclusion: Although CT findings of PBML are similar to malignancies, the clinical outcome is good. Despite the positive expression of ER and PR, the effectiveness of hormone related treatment is limited. And periodical

  7. Visualization of pulmonary nodules with magnetic resonance imaging (MRI)

    International Nuclear Information System (INIS)

    Plathow, C.; Deutsches Krebsforschungszentrum; Meinzer, H.-P.; Kauczor, H.-U.

    2006-01-01

    Visualization of pulmonary nodules using magnetic resonance imaging (MRI) plays a minor role compared with computed tomography (CT). Technical developments made it possible to apply MRI more and more frequently in functional imaging. Imaging of the motion of pulmonary nodules during respiration, e.g., to optimize high precision therapy techniques, is a new field of research. This paper describes developments in analysis and visualization of pulmonary nodules during respiration using MRI. Besides actual 2D techniques new 3D techniques to quantify motion of pulmonary nodules during respiration are presented. (orig.) [de

  8. Interstitial laser photocoagulation for benign thyroid nodules: time to treat large nodules.

    Science.gov (United States)

    Amabile, Gerardo; Rotondi, Mario; Pirali, Barbara; Dionisio, Rosa; Agozzino, Lucio; Lanza, Michele; Buonanno, Luciano; Di Filippo, Bruno; Fonte, Rodolfo; Chiovato, Luca

    2011-09-01

    Interstitial laser photocoagulation (ILP) is a new therapeutic option for the ablation of non-functioning and hyper-functioning benign thyroid nodules. Amelioration of the ablation procedure currently allows treating large nodules. Aim of this study was to evaluate the therapeutic efficacy of ILP, performed according to a modified protocol of ablation, in patients with large functioning and non-functioning thyroid nodules and to identify the best parameters for predicting successful outcome in hyperthyroid patients. Fifty-one patients with non-functioning thyroid nodules (group 1) and 26 patients with hyperfunctioning thyroid nodules (group 2) were enrolled. All patients had a nodular volume ≥40 ml. Patients were addressed to 1-3 cycles of ILP. A cycle consisted of three ILP sessions, each lasting 5-10 minutes repeated at an interval of 1 month. After each cycle of ILP patients underwent thyroid evaluation. A nodule volume reduction, expressed as percentage of the basal volume, significantly occurred in both groups (F = 190.4; P nodule volume; (iii) total amount of energy delivered expressed in Joule. ROC curves identified the percentage of volume reduction as the best parameter predicting a normalized serum TSH (area under the curve 0.962; P thyroid nodules, both in terms of nodule size reduction and cure of hyperthyroidism (87% of cured patients after the last ILP cycle). ILP should not be limited to patients refusing or being ineligible for surgery and/or radioiodine. Copyright © 2011 Wiley-Liss, Inc.

  9. The limitation and coordination of CT and positron emission tomography in the diagnosis of pulmonary nodules

    International Nuclear Information System (INIS)

    Zhang Jin'e; Liang Changhong; Zhao Zhenjun; Wang Shuxia; Qiao Suixian; He Hui; Zhang Jia; Ru Guangteng

    2005-01-01

    Objective: To Analyze the limitation and coordination of CT and positron emission tomography (PET) in the diagnosis of pulmonary nodules. Methods: A retrospective study was undertaken in 118 patients with pulmonary nodules which had CT and PET scan. The interval between examinations of various imaging equipment was less than 2 weeks. The diameter of nodules ranged from 2 cm to 4 cm with an average of 2.7 cm. The nodules were proved as lung cancer by pathology in 85 cases and metastatic tumor in 2 cases, benign nodules in 31 cases, including 8 cases of tuberculosis, 6 cases of hamartoma, 6 cases of inflammatory pseudotumor, 4 cases of chronic nonspecific inflammation, 3 cases of inflammation granuloma, 2 cases of mycosis, 1 case of abscess, and 1 case of globular atelectasis. Results: 93 cases were correctly diagnosed and 25 cases were misdiagnosed with CT in 118 cases of pulmonary nodules. The misdiagnosis rate of CT was 21.2%. 12 cases of lung cancer were misdiagnosed as benign and 13 cases of benign nodules were misdiagnosed as lung cancer. 96 cases were correctly diagnosed and 22 cases were misdiagnosed with PET. The misdiagnosis rate of PET was 18.6%. 10 cases of malignant nodules were misdiagnosed as benign and 12 cases of benign nodules were misdiagnosed as lung cancer. 108 cases were correctly diagnosed and 10 cases were misdiagnosed with CT coordinated with PET. The misdiagnosis rate was 8.5%. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of CT, PET, and CT coordinated with PET were 86.2%, 58.1%, 85.2%, 60.0%, 78.8% and 88.5%, 61.3%, 86.5%, 65.5%, 81.4%, and 97.7%, 74.2%, 91.4%, 92.0%, 91.5% respectively. The accuracy showed no significant difference between CT and PET (χ 2 =0.625, P=0.239), but there were significant difference between CT coordinated with PET and CT or PET (χ 2 =7.762 and 5.318, P=0.005 and 0021). Conclusion: The features of CT and PET in benign and malignant pulmonary nodules are partly

  10. Triple-phase enhanced MSCT in evaluating solitary pulmonary nodules

    International Nuclear Information System (INIS)

    Zhang Jin'e; Zhao Zhenjun; Liang Changhong; He Hui; Zhang Jia; Ru Guangteng

    2005-01-01

    Objective: An evaluation of the triple-phase enhanced MSCT in the assessment of solitary pulmonary nodules (SPN). Methods: Prospective study was made on 102 SPN using triple-phase enhanced MSCT, and the net elevation of the CT value of nodules as well as the neoplastic blood vessels were assessed. In total 102 patients were enrolled, including 63 males and 39 females, aged from 17 to 87 years (57.2 years in average). The nodules sized from 2.1 to 4.0 cm (3.3cm in average). Pulmonary carcinoma was proved in 71 cases and benign SPN in 31 cases(including 11 inflammatory pseudo tumors, 6 tuberculosis, 3 inflammatory granulomas, 3 lesions of acute nonspecific inflammation, 3 hamartomas, 3 mycosis and 2 abscesses). The spiral scan was performed on an 8-row detector spiral CT (GE/light speed Qx/I Extra) with 5mm/4 slices. The scan time was 1 second per circle. The 5mm sliced imaging was done for CT value measurement and 1.25mm sliced imaging was for MPR(multiplanar reconstruction) or VR(volume rendering), 20ml Ultravist(300 mg/I) was administered at first at a rate of 4ml/s via forearm superficial vein by a power injector. The peak CT values in pulmonary artery and aorta were to determine the delay time for the acquisition in pulmonary phase and aortal phase. Then Ultravist in a volume of lml/ body kilogram was injected, followed by 50 ml of sodium chloride. Delay phase was 3 minutes. Results: The differences of net increased CT value in three phases were statistically significant respectively between lung cancer and benign nodules (F=30.668, 4.495 and 56.141, respectively, P=0.000, 0.036 and 0. 000, respectively). When the net increased CT value≥20 HU was set as a diagnostic threshold, the sensitivity, specificity, positive predict value, negative predict value and veracity were 93%, 29%, 75%, 64.3% and 73.5%. When net increased CT value ≥20 HU in aortal phase while net increased CT value < 20 HU in pulmonary phase was set as a di- agnostic threshold, those values

  11. Surgical resection of highly suspicious pulmonary nodules without a tissue diagnosis

    International Nuclear Information System (INIS)

    Heo, Eun-Young; Lee, Kyung-Won; Jheon, Sanghoon; Lee, Jae-Ho; Lee, Choon-Taek; Yoon, Ho-II

    2011-01-01

    The safety and efficacy of surgical resection of lung nodule without tissue diagnosis is controversial. We evaluated direct surgical resection of highly suspicious pulmonary nodules and the clinical and radiological predictors of malignancy. Retrospective analyses were performed on 113 patients who underwent surgical resection without prior tissue diagnosis for highly suspicious pulmonary nodules. Clinical and radiological characteristics were compared between histologically proven benign and malignant nodules after resection. Total costs, length of hospitalization and waiting time to surgery were compared with those of patients who had tissue diagnosis prior to surgery. Among 280 patients with pulmonary nodules suspicious for lung cancer, 113 (40.4%) underwent operation without prior tissue diagnosis. Lung nodules were diagnosed as malignant in 96 (85%) of the 113 patients. Except for forced expiratory volume in 1 s, clinical characteristics were not significantly different according to the pathologic results. Forty-five (90%) of 50 patients with ground-glass opacity nodules had a malignancy. Mixed ground-glass opacity, bubble lucency, irregular margin and larger size correlated with malignancy in ground-glass opacity nodules (P<0.05). Fifty-one (81%) of 67 patients with solid nodules had a malignancy. Spiculation, pre-contrast attenuation and contrast enhancement significantly correlated with malignancy in solid nodules (P<0.05). Surgical resection without tissue diagnosis significantly decreased total costs, hospital stay and waiting time (P<0.05). Direct surgical resection of highly suspicious pulmonary nodules can be a valid procedure. However, careful patient selection and further investigations are required to justify direct surgical resection. (author)

  12. Indeterminate Pulmonary Nodules in Colorectal-Cancer

    DEFF Research Database (Denmark)

    Nordholm-Carstensen, Andreas; Jorgensen, Lars N; Wille-Jørgensen, Peer A

    2015-01-01

    BACKGROUND: The clinical significance of indeterminate pulmonary nodules (IPN) at staging computed tomography (CT) for colorectal cancer (CRC), and the optimal diagnostic approach, are debated. This study aimed to analyse variability in radiologists' detection of IPN at staging CT for CRC. METHODS......: All patients with CRC referred to our center between 2006 and 2011 were included. Primary staging CT scans were re-evaluated by an experienced thoracic radiologist whose findings were entered into a dedicated database and merged with data from the Danish Colorectal Cancer Group database, the National...... investigated radiological characteristics or clinicopathological factors were significantly associated with malignancy of IPN. CONCLUSION: The characterization of pulmonary findings on staging CT for CRC varied greatly between the radiologists, and double-reading of scans with IPN is recommended prior...

  13. 3D pulmonary nodules detection using fast marching segmentation ...

    African Journals Online (AJOL)

    This paper proposes an automated computer aided diagnosis system for detection of pulmonary nodules based on three dimensional (3D) structures. Lung ... The proposed detection methodology can give the accuracy of 92%. Keywords: lung cancer; pulmonary nodule; fast marching; 3D features; random forest classifier.

  14. Pattern classification approach to characterizing solitary pulmonary nodules imaged on high-resolution computed tomography

    Science.gov (United States)

    McNitt-Gray, Michael F.; Hart, Eric M.; Goldin, Jonathan G.; Yao, Chih-Wei; Aberle, Denise R.

    1996-04-01

    The purpose of our study was to characterize solitary pulmonary nodules (SPN) as benign or malignant based on pattern classification techniques using size, shape, density and texture features extracted from HRCT images. HRCT images of patients with a SPN are acquired, routed through a PACS and displayed on a thoracic radiology workstation. Using the original data, the SPN is semiautomatically contoured using a nodule/background threshold. The contour is used to calculate size and several shape parameters, including compactness and bending energy. Pixels within the interior of the contour are used to calculate several features including: (1) nodule density-related features, such as representative Hounsfield number and moment of inertia, and (2) texture measures based on the spatial gray level dependence matrix and fractal dimension. The true diagnosis of the SPN is established by histology from biopsy or, in the case of some benign nodules, extended follow-up. Multi-dimensional analyses of the features are then performed to determine which features can discriminate between benign and malignant nodules. When a sufficient number of cases are obtained two pattern classifiers, a linear discriminator and a neural network, are trained and tested using a select subset of features. Preliminary data from nine (9) nodule cases have been obtained and several features extracted. While the representative CT number is a reasonably good indicator, it is an inconclusive predictor of SPN diagnosis when considered by itself. Separation between benign and malignant nodules improves when other features, such as the distribution of density as measured by moment of inertia, are included in the analysis. Software has been developed and preliminary results have been obtained which show that individual features may not be sufficient to discriminate between benign and malignant nodules. However, combinations of these features may be able to discriminate between these two classes. With

  15. Diagnostic value of contrast-enhanced dynamic CT in predicting the malignancy of solitary pulmonary nodules

    International Nuclear Information System (INIS)

    Goo, Hyun Woo; Song, Koun Sik; Lee, Eun Hye; Kim, Ji Hoon; Lee, Jin Seong; Lim, Tae Hwan

    1997-01-01

    To determine whether the maximal enhancement time in dynamic CT is different between benign and malignant solitary pulmonary nodules (SPN)s, and to evaluate the value of densitometry on dynamic CT in predicting the malignancy of SPN. Fifty-six patients with SPN of less than 4cm in diameter as seen on chest radiograph and SPN without benign pattern of calcification or fat, as seen on pre-enhance-ment spiral CT scans were included in this study. SPN with small cavitation sufficient to measure CT density, were also included. Thirty-four SPNs were diagnosed pathologically or radiologically as 20 malignant nodules and 14 benign nodules. Dynamic CT was performed by two techniques after injection of 50ml of nonionic contrast media at the rate of 2ml/sec. In 28 patients, incremental dynamic CT was performed before and of 15 seconds, 1 minute, 2 minutes, 3 minutes, and 4 minutes after injection of contrast media during shallow respiration. In 28 patients, double spiral CT was performed 2 minutes and 3 minutes after injection of contrast media during single breath hold. CT readings were taken at the central portion of SPNs, with a circular region of interest. The degree and time of maximal enhancement were recorded. In dynamic CT the maximal enhancement time of SPNs was not significantly different between malignant (2.73±1.27 minute) and benign nodules (2.56±1.24 minute). The enhancement of malignant nodules was significantly greater (21.42±12.17 HU) than of benign nodules (5.15±5.25 HU) (p<.0001). In dynamic CT of SPNs, there is no difference in maximal enhancement time between benign and malignant nodules;enhancement of the latter is significantly greater than that of the former. Maximal enhancement greater than 15 HU can be a good predictor of malignancy of SPNs

  16. CT Fluoroscopy-Guided Core Biopsy for Diagnosis of Small ({<=} 20 mm) Pulmonary Nodules

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hye Larn; Kim, Yoon Kyung; Woo, Ok Hee; Yong, Hwan Seok; Kang, Eun Young [Dept. of Radiology, Korea University Guro Hospital, Korea University College of Medicine, Seoul (Korea, Republic of); Kim, Hyun Koo [Dept. of Thoracic Surgery, Korea University Guro Hospital, Korea University College of Medicine, Seoul (Korea, Republic of); Shin, Bong Kyung [Dept. of Pathology, Korea University Guro Hospital, Korea University College of Medicine, Seoul (Korea, Republic of)

    2011-10-15

    To evaluate the efficacy of CT fluoroscopy-guided core biopsy of small pulmonary nodules. This study included 62 patients (35 men, 27 women; age range, 36-85 years) that had a small ({<=} 20 mm) pulmonary nodule and underwent CT fluoroscopy-guided core biopsy. The overall diagnostic accuracy and complication rate were calculated. The diagnostic accuracy was compared between two groups according to the nodule size ({<=} 10 mm vs. > 10 mm), and nodule density (solid vs. subsolid). Malignant or premalignant lesions were finally diagnosed in 39 patients; 36 true-positive and three false-negative findings (sensitivity, 92%). A benign lesion was finally diagnosed in 23 patients, with no false-positive results (specificity, 100%). The overall diagnostic accuracy was 95%. The sensitivity and diagnostic accuracy were 85% and 91% for nodules {<=} 10 mm, and 96% and 97% for nodules > 10 mm (p > 0.05). The sensitivity and diagnostic accuracy were 93% and 96% in the solid group and 90% and 92% in the subsolid group (p > 0.05). Seventeen (27%) patients had a pneumothorax and two (3%) required a closed thoracostomy. CT fluoroscopy-guided core biopsy of small pulmonary nodules yields high diagnostic accuracy with acceptable complication rates.

  17. CT SCAN EVALUATION OF PULMONARY NODULE

    Directory of Open Access Journals (Sweden)

    A. Ravi Kumar

    2016-06-01

    Full Text Available BACKGROUND Lung carcinomas are quite commonly diagnosed. Thanks to the ever increasing smokers’ population. Majority of the city dwellers are at a higher risk of having this disease when compared to the village counterparts. The stigma through which the person and the family have to undergo before confirming the diagnosis is enormous. So the radiographic methods of diagnosing the malignancies have to improve. Before confirming the diagnosis, the radiologists, the treating physicians should be somewhat confident about the diagnosis so as to prepare the patients and their relatives for the most probable diagnosis before the confirmatory report. The confirmatory procedures include the PET scan and the Histopathology. Both are time consuming procedures and in an economy like ours, finding a PET scanning centre is rather difficult. So the most probable diagnosis has to be thought of using minimal resource. This study puts in a sincere effort to understand and evaluate the pulmonary nodule when identified by a CT scan. This paper is intended to help the practicing radiologists and also make life easy for a practicing physician to identify correctly the lesions and also help the patients to prevent further progression of the disease. METHODS The study was a cross-sectional study. The sample size of the study consisted of thirty patients. CT scan was done in thirty patients who were identified to have lung nodules either by other mode of radiological studies or first time identified in a CT scan itself. The study was conducted in Fathima Institute of Medical Sciences, Kadapa. The study was conducted from 2014 to 2015. RESULT Non-solid nodules were more in number when compared to the solid nodules. All the non-solid nodules were confirmed to be adenomas. Eighty percent of the nodules which were more than 8 mm in size were confirmed to be malignant. One hundred percent of the spiculated border on CT was confirmed to be malignant. In the present study

  18. Excavated pulmonary nodules: an unusual clinical presentation of lung metastasis in two cases

    Directory of Open Access Journals (Sweden)

    Lalya Issam

    2010-06-01

    Full Text Available Abstract Background Excavated pulmonary metastasis are rare. We present two cases of excavated pulmonary nodules proved to be metastases from osteosarcoma and gallblader lymphoma. Case presentation The first one is 39-year-old man in whom cholecystectomy made the diagnosis of primary non-Hodgkin's lymphoma of the gallbladder. He presented in chest CT scan excavated nodules that had been biopsied and confirmed the diagnosis of non hodgkin lymphoma. He underwent 8 courses of chemotherapy CHOP 21 with complete remission. The second one is an 21 years old man who presented a right leg osteoblastic osteosarcoma with only excavated pulmonary nodules in extension assessment. He had 3 courses of polychemotherapy API (doxorubicin, platinum, and ifosfamide with partial response. Unfortunately, he died following a septic shock. Review of the literature shows that excavated pulmonary nodules as metastasis are rare but we should consider this diagnosis every time we are in front of a cancer. Chest computed tomography is the best diagnosis imaging that could make this diagnosis. Differential diagnosis between benign and malignant bullous lesions is important because surgical excision affects survival in some malignancies. Conclusions Although pulmonary nodules are the most common cancer metastasis, a differential diagnosis of a concurrent primary malignancy should always be considered every time we have excavated lesions, even in patients with known malignant disease. Thorough chest evaluation is important, as multiple primary malignancies may occur concomitantly.

  19. Subcentimeter Pulmonary Nodules Detected in Patients with Sarcoma

    Directory of Open Access Journals (Sweden)

    Michelle S. Ginsberg

    2000-01-01

    Full Text Available Background. Subcentimeter pulmonary nodules are being detected with increasing frequency in patients with sarcoma due to the greater use of chest CT, the advent of helical (spiral CT scanning and multidetector scanners, and the attendant decrease in image section thickness.Assessing the clinical significance of these pulmonary nodules is of particular importance in sarcoma patients, due to the frequent occurrence of pulmonary metastasis from sarcomas.

  20. Initial application of digital tomosynthesis for detection of pulmonary nodules

    International Nuclear Information System (INIS)

    Sun Zhiyuan; Su Hong; Zhao Yane; Ju Bing; Chang Shuanghui; Hu Qiuju; Lu Guangming

    2010-01-01

    Objective: To discuss the value of digital tomosynthesis for detection of pulmonary nodules. Methods: Thirty patients suspected of having pulmonary nodules underwent chest radiography, digital tomosynthesis and CT examination. Above image data were transferred to postprocessing work station and were reviewed by 2 radiologists with 3 years of chest-radiology diagnosis experience in a double-blind method. The number, location and size of nodules were recorded. Then, 2 radiologists reviewed the all images once more, and discuss in consensus. The sensitivities of chest radiography and digital tomosynthesis for detection of pulmonary nodules were respectively calculated according to the CT results. Chi-square test was used for radiography, digital tomosynthesis and CT examination. Results: Of 30 patients, 21 were detected having pulmonary nodules by X-ray radiography and 9 were negative, the total number of 40 nodules was detected, while 89 nodules in 26 patients were detected by digital tomosynthesis, and only 4 patients were negative. CT demonstrated 102 nodules in 27 patients, and 3 patients were negative. Taking CT as 'gold standard', the sensitivities of X-ray radiography and digital tomosynthesis were 27.4%(28/102)and 87.2%(89/102), X 2 =4.35, P<0.05, respectively. Conclusion: Digital tomosynthesis has a high sensitivity for detection of pulmonary nodules compared with X-ray radiography, and could be an excellent and necessary supplementary technique of X-ray radiography. (authors)

  1. Diagnostic work-up of pulmonary nodules. Management of pulmonary nodules detected with low-dose CT screening; Abklaerung von Lungenrundherden. Management durch Frueherkennungsuntersuchungen detektierter pulmonaler Rundherde

    Energy Technology Data Exchange (ETDEWEB)

    Wormanns, D. [Evangelische Lungenklinik Berlin, Berlin (Germany)

    2016-09-15

    Pulmonary nodules are the most frequent pathological finding in low-dose computed tomography (CT) scanning for early detection of lung cancer. Early stages of lung cancer are often manifested as pulmonary nodules; however, the very commonly occurring small nodules are predominantly benign. These benign nodules are responsible for the high percentage of false positive test results in screening studies. Appropriate diagnostic algorithms are necessary to reduce false positive screening results and to improve the specificity of lung cancer screening. Such algorithms are based on some of the basic principles comprehensively described in this article. Firstly, the diameter of nodules allows a differentiation between large (>8 mm) probably malignant and small (<8 mm) probably benign nodules. Secondly, some morphological features of pulmonary nodules in CT can prove their benign nature. Thirdly, growth of small nodules is the best non-invasive predictor of malignancy and is utilized as a trigger for further diagnostic work-up. Non-invasive testing using positron emission tomography (PET) and contrast enhancement as well as invasive diagnostic tests (e.g. various procedures for cytological and histological diagnostics) are briefly described in this article. Different nodule morphology using CT (e.g. solid and semisolid nodules) is associated with different biological behavior and different algorithms for follow-up are required. Currently, no obligatory algorithm is available in German-speaking countries for the management of pulmonary nodules, which reflects the current state of knowledge. The main features of some international and American recommendations are briefly presented in this article from which conclusions for the daily clinical use are derived. (orig.) [German] Lungenrundherde sind die haeufigsten pathologischen Befunde bei Untersuchungen mit der Niedrigdosis-CT zur Lungenkrebsfrueherkennung. Fruehstadien des Lungenkarzinoms manifestieren sich meist als Rundherd

  2. Qualitative ultrasound elastography assessment of benign thyroid nodules: Patterns and intra-observer acquisition variability

    International Nuclear Information System (INIS)

    Lacout, Alexis; Chevenet, Carole; Thariat, Juliette; Figl, Andrea; Marcy, Pierre-Yves

    2013-01-01

    To report and evaluate qualitative elastography patterns by using gray-scale and Doppler ultrasound (US) in patients presenting with benign thyroid nodules and to evaluate the reproducibility of US elastography examinations. Institutional review board approval was obtained, and all patients provided informed consent. Over a 3-month time period, all consecutive adult patients were referred to our institution to undergo a thyroid nodule fine-needle aspiration biopsy (FNAB) procedure. Patients presenting with benign cytology according to the Bethesda 2008 classification were prospectively enrolled in the study. Each thyroid nodule was assessed by using gray-scale, Doppler US, and elastography acquisitions by a single operator (A. L.). Multiple elastography acquisitions per thyroid nodule were performed and elastography scorings of the nodules were compared with each other. Nineteen patients (16 women and 3 men, mean age 58 years) with 22 thyroid nodules were included in the present study. Elastographic patterns 1, 2, and 3 were reported (23% nodules showed pattern 3). The elastography pattern showed a strong variability in 13 nodules (59%). The elastography acquisition result variability involved the “malignant” pattern 3 in 36% of cases. Almost one-third of benign thyroid nodules displayed pattern 3 on qualitative US elastography. The intra-observer variability of the benign thyroid elastography scoring is wide, thus limiting the thyroid nodule US examination accuracy. In FNAB-proven benign thyroid nodules, elastography pattern 3 is frequent and cannot be used as a strong indicator of thyroid malignancy

  3. Correlation study of multislice spiral CT and pathology in relationship between solitary pulmonary nodule and bronchus

    International Nuclear Information System (INIS)

    Qiang Jinwei; Ye Xuanguang; Zhou Kangrong; Jiang Yaping; Wang Qun; Xu Songtao; Tan Lijie

    2003-01-01

    Objective: To investigate the relationship between solitary pulmonary nodule (SPN) and bronchus and its value in predicting the nature of nodule. Methods: Continuous volume targeted scans of 0.5 mm collimation were prospectively performed with multislice spiral CT (MSCT) and reconstructed images of MPR, CPR, and SSD in workstation in 75 patients of SPN with ≤3 cm in diameter were acquired. The emphasis was paid on the manifestation of the shapes and patterns of SPN with related bronchi. The results were correlated with macroscopic and microscopic specimens. Results: (1) The SPN-bronchus relationship was shown very clearly in all patients by the designed protocol. CT demonstrated the relations between SPN and bronchus in 44 (86.3%) malignant and 16 (66.7%) benign nodules. There was no statistically significant difference (P=0.065). (2) Five types of SPN-bronchus relationship were identified with MSCT. Type I: bronchus was obstructed abruptly by the SPN, type II: bronchus penetrated into SPN with tapered narrow and interruption, type III: bronchus lumen shown within SPN was patent and intact, type IV: bronchus ran at the periphery of SPN with intact lumen, and type V: bronchus was displaced, compressed, and narrowed by SPN. (3) With respect to the nature of SPN, malignant nodule most commonly showed type I, secondly type IV, and rarely type V. Benign nodule most often showed type V, secondly type I, and no type II. With respect to the pattern, type I, II, and IV patterns were more commonly seen in malignant nodule, whereas type V pattern was seen frequently in benign nodule. Type III pattern was slightly more common in benign cases. Conclusion: Spiral targeted scan of ultra-thin section with MSCT and followed by MPR, CPR, and SSD reconstruction can greatly improve the manifestation of the bronchioles and accurately demonstrate the patterns of SPN-bronchus relationship. Varied patterns are corresponding to certain nodule and reflect definite pathologic changes

  4. Subsolid pulmonary nodules: imaging evaluation and strategic management.

    Science.gov (United States)

    Godoy, Myrna C B; Sabloff, Bradley; Naidich, David P

    2012-07-01

    Given the higher rate of malignancy of subsolid pulmonary nodules and the considerably lower growth rate of ground-glass nodules (GGNs), dedicated standardized guidelines for management of these nodules have been proposed, including long-term low-dose computed tomography (CT) follow-up (≥3 years). Physicians must be familiar with the strategic management of subsolid pulmonary nodules, and should be able to identify imaging features that suggest invasive adenocarcinoma requiring a more aggressive management. Low-dose CT screening studies for early detection of lung cancer have increased our knowledge of pulmonary nodules, and in particular our understanding of the strong although imperfect correlation of the subsolid pulmonary nodules, including pure GGNs and part-solid nodules, with the spectrum of preinvasive to invasive lung adenocarcinoma. Serial CT imaging has shown stepwise progression in a subset of these nodules, characterized by increase in size and density of pure GGNs and development of a solid component, the latter usually indicating invasive adenocarcinoma. There is close correlation between the CT features of subsolid nodules (SSNs) and the spectrum of lung adenocarcinoma. Standardized guidelines are suggested for management of SSNs.

  5. VATS intraoperative tattooing to facilitate solitary pulmonary nodule resection

    Directory of Open Access Journals (Sweden)

    Boutros Cherif

    2008-03-01

    Full Text Available Abstract Introduction Video-assisted thoracic surgery (VATS has become routine and widely accepted for the removal of solitary pulmonary nodules of unknown etiology. Thoracosopic techniques continue to evolve with better instruments, robotic applications, and increased patient acceptance and awareness. Several techniques have been described to localize peripheral pulmonary nodules, including pre-operative CT-guided tattooing with methylene blue, CT scan guided spiral/hook wire placement, and transthoracic ultrasound. As pulmonary surgeons well know, the lung and visceral pleura may appear featureless on top of a pulmonary nodule. Case description This paper presents a rapid, direct and inexpensive approach to peripheral lung lesion resection by marking the lung parenchyma on top of the nodule using direct methylene blue injection. Methods In two patients with peripherally located lung nodules (n = 3 scheduled for VATS, we used direct methylene blue injection for intraoperative localization of the pulmonary nodule. Our technique was the following: After finger palpation of the lung, a spinal 25 gauge needle was inserted through an existing port and 0.1 ml of methylene blue was used to tattoo the pleura perpendicular to the localized nodule. The methylene blue tattoo immediately marks the lung surface over the nodule. The surgeon avoids repeated finger palpation, while lining up stapler, graspers and camera, because of the visible tattoo. Our technique eliminates regrasping and repalpating the lung once again to identify a non marked lesion. Results Three lung nodules were resected in two patients. Once each lesion was palpated it was marked, and the area was resected with security of accurate localization. All lung nodules were resected in totality with normal lung parenchymal margins. Our technique added about one minute to the operative time. The two patients were discharged home on the second postoperative day, with no morbidity. Conclusion

  6. The Effects of Iodine Attenuation on Pulmonary Nodule Volumetry using Novel Dual-Layer Computed Tomography Reconstructions.

    Science.gov (United States)

    den Harder, A M; Bangert, F; van Hamersvelt, R W; Leiner, T; Milles, Julien; Schilham, A M R; Willemink, M J; de Jong, P A

    2017-12-01

    To assess the effect of iodine attenuation on pulmonary nodule volumetry using virtual non-contrast (VNC) and mono-energetic reconstructions. A consecutive series of patients who underwent a contrast-enhanced chest CT scan were included. Images were acquired on a novel dual-layer spectral CT system. Conventional reconstructions as well as VNC and mono-energetic images at different keV levels were used for nodule volumetry. Twenty-four patients with a total of 63 nodules were included. Conventional reconstructions showed a median (interquartile range) volume and diameter of 174 (87 - 253) mm 3 and 6.9 (5.4 - 9.9) mm, respectively. VNC reconstructions resulted in a significant volume reduction of 5.5% (2.6 - 11.2%; p<0.001). Mono-energetic reconstructions showed a correlation between nodule attenuation and nodule volume (Spearman correlation 0.77, (0.49 - 0.94)). Lowering the keV resulted in increased volumes while higher keV levels resulted in decreased pulmonary nodule volumes compared to conventional CT. Novel dual-layer spectral CT offers the possibility to reconstruct VNC and mono-energetic images. Those reconstructions show that higher pulmonary nodule attenuation results in larger nodule volumes. This may explain the reported underestimation in nodule volume on non-contrast enhanced compared to contrast-enhanced acquisitions. • Pulmonary nodule volumes were measured on virtual non-contrast and mono-energetic reconstructions • Mono-energetic reconstructions showed that higher attenuation results in larger volumes • This may explain the reported nodule volume underestimation on non-contrast enhanced CT • Mostly metastatic pulmonary nodules were evaluated, results might differ for benign nodules.

  7. Multidetector computed tomography analysis of benign and malignant nodules in patients with chronic lymphocytic thyroiditis.

    Science.gov (United States)

    Zhu, Caisong; Liu, Wei; Yang, Jun; Yang, Jing; Shao, Kangwei; Yuan, Lixin; Chen, Hairong; Lu, Wei; Zhu, Ying

    2016-07-01

    The aim of the present study was to compare the multidetector computed tomography (MDCT) features of benign and malignant nodules in patients with chronic lymphocytic thyroiditis (CLT). MDCT findings, including the size, solid percentage, calcification, margin, capsule, anteroposterior-transverse diameter ratio as well as the mode and the degree of enhancement of 137 thyroid nodules in 127 CLT cases were retrospectively analyzed. Furthermore, the correlation between MDCT findings and pathological results combined with the CT perfusion imaging was analyzed for the differences between benign and malignant nodules. A total of 77.5% (31/40) of malignant nodules were completely solid, and 33% (32/97) of benign nodules were predominantly cystic. Compared with the benign nodules, micro-calcification and internal calcification were more frequently observed in the malignant nodules (Pbenign and malignant nodules (P>0.05). MDCT features are useful in differentiating the benign and malignant nodules in CLT patients, and it may be essential for a radiologist to review the MDCT characteristics of nodules in the clinical practice.

  8. Volumetry of Artificial Pulmonary Nodules in Ex Vivo Porcine Lungs: Comparison of Semi-automated Volumetry and Radiologists' Performance

    International Nuclear Information System (INIS)

    Jeong, Ju Hyeon; Kim, Jin Hwan; Kim, Song Soo; Jeon, Ho Sang; Lee, Hyun Ju; Park, Noh Hyuck; Cho, Gyu Seong

    2010-01-01

    With the advent of MSCT, the detection rate of small pulmonary nodules is markedly greater. However, there is no definite diagnostic clue to differentiate between malignant and benign nodules, except for the interval growth in small nodule less than 1 cm in diameter. We evaluated the accuracy of computer aided volumetry (CAV) and compared it with 4 radiologists' measurement. Fifteen artificial nodules that were embedded in the ex vivo porcine lung were scanned by MSCT. The diameters and volumes of nodules were independently measured three times, at 5-day intervals, and by four radiologists as well as by CAV. We evaluated the accuracy of the measurements on the basis of the true diameter and volume of the nodules. Using a paired t-test and a Bland-Altman plot, we evaluated whether there was a statistically significant difference between the radiologists' measurements and the CAV. The accuracy of the manual measurements by radiologists revealed a statistically significant difference from the true diameter and volume of the artificial nodules (p 0.01) The results of this study suggest that CAV is an accurate and useful tool to evaluate the volume of pulmonary nodules and can eventually be used to differentiate malignant and benign nodules as well as evaluate the therapeutic response of lung cancer

  9. Solitary pulmonary nodule: radiologic features and diagnostic approach

    International Nuclear Information System (INIS)

    Rodriguez Cambronero, Luis Enrique

    2012-01-01

    A literature review is conducted on the solitary pulmonary nodule, to determine the diagnostic methods and specific characteristics. The diagnostic methods used have been: chest radiography, computed tomography, positron emission tomography and magnetic resonance imaging. The radiological features are defined: location, size, definition of contours or edges (margins), densitometric and attenuation characteristics, cavitation, air bronchogram, growth, doubling time, satellite nodules, nutrient vessels [es

  10. The inhomogeneous perfusion of the solitary pulmonary nodules

    International Nuclear Information System (INIS)

    Li Shenjiang; Xiao Xiangsheng; Liu Shiyuan; Li Chengzhou; Zhang Chenshi

    2008-01-01

    Objective: To investigate whether the perfusion of the solitary pulmonary nodules (SPNs) is homogeneous derived with 16-slice spiral CT and 64-slice spiral CT. Methods: Eight-five patients with. SPNs (diameter≤4 cm; 57 maliagnant; 15 active inflammatory; 13 benign) underwent multi- location dynamic contrast material-enhanced serial CT. One scan was obtained every 1 seconds during 11-- 41 seconds without scanning interval after injection, one scan was obtained at 90 seconds. TOSHIBA AquilionMarconi 16: The section thickness was 8.0 mm for lesions 3.0-4.0 cm, 6.0 mm for 2.0- 3.0 cm, 4.0 mm for 1.5-2.0 cm, 3.0 mm for 1.0-1.5 cm and 2.0 mm for lesions -1 ·100 g -1 , the ratios of peak height of the SPN to that of the aorta (13.58±6.41)%, (10.95±5.76)%, (13.64± 6.20)% and the mean transit times (11.61±5.74), (11.97±3.55), (13.44±3.74) s. Statistically significant differences were found among three sections in the peak height (F=5.913, P=0.003), perfusion (F=6.464,P=0.002), ratio of peak height of the SPN to that of the aorta(F=5.333,P=0.005) and mean transit time (F=3.837, P=0.023). No statistically significant differences were found among three sections in precontrast attenuation (F=0.032, P=0.968). Conclusion: The volume perfusion of the SPNs is inhomogeneous, it is suggested to evaluate blood flow patterns of the solitary pulmonary nodules with CT volume perfusion imaging. (authors)

  11. Computer-aided detection of pulmonary nodules: influence of nodule characteristics on detection performance

    International Nuclear Information System (INIS)

    Marten, K.; Engelke, C.; Seyfarth, T.; Grillhoesl, A.; Obenauer, S.; Rummeny, E.J.

    2005-01-01

    AIM: To evaluate prospectively the influence of pulmonary nodule characteristics on detection performances of a computer-aided diagnosis (CAD) tool and experienced chest radiologists using multislice CT (MSCT). MATERIALS AND METHODS: MSCT scans of 20 consecutive patients were evaluated by a CAD system and two independent chest radiologists for presence of pulmonary nodules. Nodule size, position, margin, matrix characteristics, vascular and pleural attachments and reader confidence were recorded and data compared with an independent standard of reference. Statistical analysis for predictors influencing nodule detection or reader performance included chi-squared, retrograde stepwise conditional logistic regression with odds ratios and nodule detection proportion estimates (DPE), and ROC analysis. RESULTS: For 135 nodules, detection rates for CAD and readers were 76.3, 52.6 and 52.6%, respectively; false-positive rates were 0.55, 0.25 and 0.15 per examination, respectively. In consensus with CAD the reader detection rate increased to 93.3%, and the false-positive rate dropped to 0.1/scan. DPEs for nodules ≤5 mm were significantly higher for ICAD than for the readers (p<0.05). Absence of vascular attachment was the only significant predictor of nodule detection by CAD (p=0.0006-0.008). There were no predictors of nodule detection for reader consensus with CAD. In contrast, vascular attachment predicted nodule detection by the readers (p=0.0001-0.003). Reader sensitivity was higher for nodules with vascular attachment than for unattached nodules (sensitivities 0.768 and 0.369; 95% confidence intervals=0.651-0.861 and 0.253-0.498, respectively). CONCLUSION: CAD increases nodule detection rates, decreases false-positive rates and compensates for deficient reader performance in detection of smallest lesions and of nodules without vascular attachment

  12. Pulmonary Nodules with Cutaneous Manifestations: A Case Report and Discussion

    Directory of Open Access Journals (Sweden)

    Ardiles T

    2012-04-01

    Full Text Available The differential diagnosis of multiple pulmonary nodules is large and includes congenital and inherited disorders, malignancy, infectious etiologies, noninfectious granulomatous and inflammatory conditions,among many others. Diagnostic evaluation is aided by attention to extrapulmonary symptoms and features. We herein describe an unusual case of multiple pulmonary nodules attributed to cysticercosis and present a discussion of pathophysiologic changes related to medications and highlight the diagnostic value of extrapulmonary cutaneous features.

  13. Pulmonary Benign Metastasizing Leiomyoma from the Uterine Leiomyoma: A Case Report

    International Nuclear Information System (INIS)

    Kołaczyk, Katarzyna; Chamier-Ciemińska, Katarzyna; Walecka, Anna; Chosia, Maria; Szydłowska, Iwona; Starczewski, Andrzej; Grodzki, Tomasz; Smereczyński, Andrzej; Sawicki, Marcin

    2015-01-01

    Benign metastasizing leiomyoma (BML) is a rare condition described as multiple well-differentiated leiomyomas at sites distant from the uterus. Apart from lungs it has also been reported in lymph nodes, heart, brain, bone, skin, eye and spinal cord. We present a case of pulmonary benign metastasizing leiomyoma in a female patient admitted to our hospital with suspicion of left adnexal tumor. A 45-year-old woman was referred to our hospital with suspicion of left adnexal tumor. The control transvaginal ultrasound examination performed at admission to the Gynecological Department excluded adnexal neoplasm. However, a large amount of fluid within the Douglas pouch raised the oncological concern. The patient underwent myomectomy in 2005. In the same year she was diagnosed with multiple lung nodules and underwent pulmonary wedge resection with the diagnosis of pulmonary benign metastasizing leiomyoma being stated. The decision of reevaluation of the specimen, control CT and puncture of the Douglas pouch fluid was made. Computed tomography performed at the Department of Diagnostic Imaging and Interventional Radiology of the Pomeranian Medical University Hospital revealed multiple, bilateral nodules. The microscopic examination of the samples confirmed the initial diagnosis of benign metastasizing leiomyoma with no evidence of neoplastic cells within the fluid. Pulmonary benign metastasizing leiomyoma is a rare entity. However, it should be always taken into consideration in women with a previous or coincident history of uterine leiomyoma, especially when no evidence of other malignancy is present

  14. Solitary pulmonary nodule and 18F-FDG PET/CT. Part 1: epidemiology, morphological evaluation and cancer probability

    Directory of Open Access Journals (Sweden)

    Marcos Pretto Mosmann

    2016-02-01

    Full Text Available Abstract Solitary pulmonary nodule corresponds to a common radiographic finding, which is frequently detected incidentally. The investigation of this entity remains complex, since characteristics of benign and malignant processes overlap in the differential diagnosis. Currently, many strategies are available to evaluate solitary pulmonary nodules with the main objective of characterizing benign lesions as best as possible, while avoiding to expose patients to the risks inherent to invasive methods, besides correctly detecting cases of lung cancer so as the potential curative treatment is not delayed. This first part of the study focuses on the epidemiology, the morfological evaluation and the methods to determine the likelihood of cancer in cases of indeterminate solitary pulmonary nodule.

  15. Thallium 201 thyroid scan: differential diagnosis of benign and malignant nodules

    International Nuclear Information System (INIS)

    Oh, Jong Sub; Kim, Byong Geun; Park, Byung Ran; Kim, Se Jong; Ko, Kang Seok; Kim, Min Joong; Ji, Joo Yun

    1995-01-01

    To evaluate useful findings and diagnostic value of TI-201 thyroid scan in differentiating benign from malignant nodules. We studied 77 cold thyroid nodules proven histologically(27 malignant and 50 benign). Early (5-15 min) and delayed images(3-5 hours) were obtained after intravenous injection of thallium 201. In these nodules, we retrospectively analyzed the degree of TI-201 uptake in early and delayed images, histopathologic type, size, and presence or absence of cystic change in the sonograms of 22 malignant nodules. Useful finding for diagnosis of malignant nodules was strong uptake of TI-201 in early and delayed images(specificity: 98%, sensitivity: 63%, positive predictive value: 94.4%). Useful finding for benign nodules was no uptake of TI-201 in delayed image(specificity: 88.9%, sensitivity: 68%, positive predictive value: 91.9%). The accuracy of TI-201 thyroid scan in differentiating benign from malignant nodules was 66.2%. The nodules with strong TI-201 uptake in early image and low TI-201 uptake in delayed image were malignant in 29.4%. Cystic changes were found in 40% of malignant nodules with atypical TI-201 uptake. TI-201 thyroid scan showed high specificity in follicular neoplasm and adenomatous goiter in which differentiation of benignancy and malignancy is difficult with only cytologic examination. We consider that TI-201 thyroid scan is valuable in differentiating benign from malignant nodules and when combined with fine needle aspiration and ultrasound examination, it will enable more accurate differential diagnosis between benign and malignant thyroid nodules

  16. FDG uptake heterogeneity evaluated by fractal analysis improves the differential diagnosis of pulmonary nodules

    Energy Technology Data Exchange (ETDEWEB)

    Miwa, Kenta, E-mail: kenta5710@gmail.com [Department of Nuclear Medicine, Cancer Institute Hospital of Japanese Foundation for Cancer Research, 3-8-31 Ariake, Koto-ku, Tokyo 135-8550 (Japan); Division of Medical Quantum Science, Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan); Inubushi, Masayuki, E-mail: inubushi@med.kawasaki-m.ac.jp [Department of Nuclear Medicine, Kawasaki Medical School, 577 Matsushima Kurashiki, Okayama 701-0192 (Japan); Wagatsuma, Kei, E-mail: kei1192@hotmail.co.jp [Department of Nuclear Medicine, Cancer Institute Hospital of Japanese Foundation for Cancer Research, 3-8-31 Ariake, Koto-ku, Tokyo 135-8550 (Japan); Nagao, Michinobu, E-mail: minagao@radiol.med.kyushu-u.ac.jp [Department of Molecular Imaging and Diagnosis, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan); Murata, Taisuke, E-mail: taisuke113@gmail.com [Department of Nuclear Medicine, Cancer Institute Hospital of Japanese Foundation for Cancer Research, 3-8-31 Ariake, Koto-ku, Tokyo 135-8550 (Japan); Koyama, Masamichi, E-mail: masamichi.koyama@jfcr.or.jp [Department of Nuclear Medicine, Cancer Institute Hospital of Japanese Foundation for Cancer Research, 3-8-31 Ariake, Koto-ku, Tokyo 135-8550 (Japan); Koizumi, Mitsuru, E-mail: mitsuru@jfcr.or.jp [Department of Nuclear Medicine, Cancer Institute Hospital of Japanese Foundation for Cancer Research, 3-8-31 Ariake, Koto-ku, Tokyo 135-8550 (Japan); Sasaki, Masayuki, E-mail: msasaki@hs.med.kyushu-u.ac.jp [Division of Medical Quantum Science, Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan)

    2014-04-15

    Purpose: The present study aimed to determine whether fractal analysis of morphological complexity and intratumoral heterogeneity of FDG uptake can help to differentiate malignant from benign pulmonary nodules. Materials and methods: We retrospectively analyzed data from 54 patients with suspected non-small cell lung cancer (NSCLC) who were examined by FDG PET/CT. Pathological assessments of biopsy specimens confirmed 35 and 19 nodules as NSCLC and inflammatory lesions, respectively. The morphological fractal dimension (m-FD), maximum standardized uptake value (SUV{sub max}) and density fractal dimension (d-FD) of target nodules were calculated from CT and PET images. Fractal dimension is a quantitative index of morphological complexity and tracer uptake heterogeneity; higher values indicate increased complexity and heterogeneity. Results: The m-FD, SUV{sub max} and d-FD significantly differed between malignant and benign pulmonary nodules (p < 0.05). Although the diagnostic ability was better for d-FD than m-FD and SUV{sub max}, the difference did not reach statistical significance. Tumor size correlated significantly with SUV{sub max} (r = 0.51, p < 0.05), but not with either m-FD or d-FD. Furthermore, m-FD combined with either SUV{sub max} or d-FD improved diagnostic accuracy to 92.6% and 94.4%, respectively. Conclusion: The d-FD of intratumoral heterogeneity of FDG uptake can help to differentially diagnose malignant and benign pulmonary nodules. The SUV{sub max} and d-FD obtained from FDG-PET images provide different types of information that are equally useful for differential diagnoses. Furthermore, the morphological complexity determined by CT combined with heterogeneous FDG uptake determined by PET improved diagnostic accuracy.

  17. Diagnostic procedures of the solitary pulmonary nodule

    International Nuclear Information System (INIS)

    Aoe, Keisuke; Hiraki, Akio; Kohara, Hiroyuki

    2003-01-01

    The spread of computed tomography (CT) brought the frequent further examinations of the solitary pulmonary nodules (SPN). To aim the evaluation of initial data on examinations of SPN for differential diagnosis, we studied retrospective cases. Thirty-one cases of SPN less than 20 mm in diameter were compared in clinical findings and CT image findings and were examined the diagnostic procedures in recent three years in National Sanyo Hospital. The 31 patients consisted of 14 males and 17 females ranging 44 to 79 years old, median 65 years old. The causes of SPN were lung cancer (11 patients), cryptococcosis (4 patients), tuberculoma (3 patients), non-tuberculous mycobacteria (2 patients), pneumoconiosis (2 patients), pneumonia scar (one patient), hamartoma (one patient), and unknown (7 patients). There were no significant differences in laboratory findings between lung cancer and the others. CT findings showed significant differences in four categories. All patients underwent fiberoptic bronchoscopy (FB) examinations and 12 patients were determined the diagnosis initial FB. Five patients were established their diagnosis using videoassociated thoracoscopic surgeries. (author)

  18. Classification decision tree in CT imaging: application to the differential diagnosis of solitary pulmonary nodules

    International Nuclear Information System (INIS)

    Ma Hongxia; Guo Yulin; Wang Qiuping; Qiang Yongqian; Liu Min; Guo Xiaojuan; Guo Youmin; Chen Qihang

    2008-01-01

    Objective: To establish classification and regression tree (CART) for differentiating benign from malignant solitary pulmonary nudules (SPN). Methods: One hundred and sixteen consecutive cases with 116 solitary pulmonary nodules, which finally were pathologically proven 54 malignant nodules and 62 benign nodules, were prospectively registered in this research. Twelve clinical presentations and 22 CT findings were collected as predictors. A classification tree was established to distinguish benign SPNs from malignant ones. In the observer test, two groups (one made of junior radiologists and one of senior radiologists) were independently presented with clinical information and CT images without knowing the pathologic and machine-learning results. Performance of observers and CART were compared by receiver operating characteristic analysis. Results: Receiver operating characteristic analysis showed areas under the curve of CART, senior radiologists and junior radiologists respectively were 0.910±0.029, 0.827±0.038, 0.612±0.052. Difference between areas(DBF) between CART and junior radiologists was 0.297(P<0.01). DBF between CART and senior radiologists was 0.083 (P<0.05). DBF between senior and junior radiologists was 0.214 (P<0.01). CART showed a best diagnostic efficiency, followed by junior radiologists, and then senior radiologists. Conclusion: Our data mining techniques using CART prove a high accuracy in differentiating benign from malignant pulmonary nodules based on clinical variables and CT findings. It will be a potentially useful tool in further application of artificial intelligence in the imaging diagnosis. (authors)

  19. Diagnostic Accuracy of MRI-guided Percutaneous Transthoracic Needle Biopsy of Solitary Pulmonary Nodules

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Shangang, E-mail: 1198685580@qq.com [University of Jinan-Shandong Academy of Medical Science, Department of Radiation Oncology, Shandong Cancer Hospital and Institute, School of Medicine and Life Sciences (China); Li, Chengli, E-mail: chenglilichina@yeah.net [Shandong University, Department of Interventional MRI, Shandong Medical Imaging Research Institute (China); Yu, Xuejuan, E-mail: yuxuejuan2011@126.com [University of Jinan-Shandong Academy of Medical Science, Department of Radiation Oncology, Shandong Cancer Hospital and Institute, School of Medicine and Life Sciences (China); Liu, Ming, E-mail: mingliuyxs@163.com [Shandong University, Department of Interventional MRI, Shandong Medical Imaging Research Institute (China); Fan, Tingyong, E-mail: FTY681105@sohu.com; Chen, Dong, E-mail: 857984870@qq.com; Zhang, Pinliang, E-mail: zhangpinliang@163.com; Ren, Ruimei, E-mail: liusg708@qq.com [University of Jinan-Shandong Academy of Medical Science, Department of Radiation Oncology, Shandong Cancer Hospital and Institute, School of Medicine and Life Sciences (China)

    2015-04-15

    ObjectiveThe purpose of our study was to evaluate the diagnostic accuracy of MRI-guided percutaneous transthoracic needle biopsy (PTNB) of solitary pulmonary nodules (SPNs).MethodsRetrospective review of 69 patients who underwent MR-guided PTNB of SPNs was performed. Each case was reviewed for complications. The final diagnosis was established by surgical pathology of the nodule or clinical and imaging follow-up. Pneumothorax rate and diagnostic accuracy were compared between two groups according to nodule diameter (≤2 vs. >2 cm) using χ{sup 2} chest and Fisher’s exact test, respectively.ResultsThe success rate of single puncture was 95.6 %. Twelve (17.4 %) patients had pneumothorax, with 1 (1.4 %) requiring chest tube insertion. Mild hemoptysis occurred in 7 (7.2 %) patients. All of the sample material was sufficient for histological diagnostic evaluation. Pathological analysis of biopsy specimens showed 46 malignant, 22 benign, and 1 nondiagnostic nodule. The final diagnoses were 49 malignant nodules and 20 benign nodules basing on postoperative histopathology and clinical follow-up data. One nondiagnostic sample was excluded from calculating diagnostic performance. A sensitivity, specificity, accuracy, positive predictive value, and negative predictive value in diagnosing SPNs were 95.8, 100, 97.0, 100, and 90.9 %, respectively. Pneumothorax rate, diagnostic sensitivity, and accuracy were not significantly different between the two groups (P > 0.05).ConclusionsMRI-guided PTNB is safe, feasible, and high accurate diagnostic technique for pathologic diagnosis of pulmonary nodules.

  20. Comparative analysis between spiral CT and pathology of pulmonary nodules

    International Nuclear Information System (INIS)

    Wang Kaifu; Zhang Zhanqing

    2007-01-01

    Objective: To explore the value of spiral CT in the diagnosis of atypical pulmonary nodules. Methods: CT, clinic and histopathologic data of 72 patients with atypical pulmonary nodules confirmed by surgical resection in 41 cases and/or biopsy in 31 cases were retrospectively analyzed. Results: CT scans demonstrated slight lobulation in 34 cases, irregular margin in 50 cases, long speculate in 10 cases, air-bronchogram in 2 case, vacuole in 2 case. 38 pulmonary cancer, 22 pulmonary tuberculosis and 12 pulmonary inflammatory pseudotumors were diagnosed with spiral CT. However, 30 pulmonary cancer, 30 pulmonary tuberculosis and 12 pulmonary inflammatory pseudotumors were confirmed by histopathology. The overall accurate diagnostic rate of pulmonary cancer was 66.7% (20/30), pulmonary tuberculosis was 60%(18/30), pulmonary inflammatory pseudotumors was 16.7%(2/12). 40 cases were diagnosed correctly and 32 cases were misdiagnosed with CT in 72 cases of atypical pulmonary nodules. The misdiagnostic rate of CT was 44.4%. 10 cases of lung cancer were misdiagnosed, including 4 cases of tuberculosis (long speculate or irregular margin) and 6 cases of inflammatory pseudotumors (irregular margin or long speculate or air-bronchogram). 12 cases of tuberculosis were misdiagnosed, including 8 cases lung cancer (slight lobulation) and 4 cases of inflammatory pseudotumors (slight lobulation). 10 cases inflammatory pseudotumor were misdiagnosed as lung cancer (slight lobulation). Conclusion: Spiral CT was very useful in the localization and morphological describing, but difficult in qualitative diagnosing of atypical pulmonary nodules, exactly diagnosis was relied on surgery and biopsy. (authors)

  1. Feasibility of Intravoxel Incoherent Motion for Differentiating Benign and Malignant Thyroid Nodules.

    Science.gov (United States)

    Tan, Hui; Chen, Jun; Zhao, Yi Ling; Liu, Jin Huan; Zhang, Liang; Liu, Chang Sheng; Huang, Dongjie

    2018-06-13

    This study aimed to preliminarily investigate the feasibility of intravoxel incoherent motion (IVIM) theory in the differential diagnosis of benign and malignant thyroid nodules. Forty-five patients with 56 confirmed thyroid nodules underwent preoperative routine magnetic resonance imaging and IVIM diffusion-weighted imaging. The histopathologic diagnosis was confirmed by surgery. Apparent diffusion coefficient (ADC), perfusion fraction f, diffusivity D, and pseudo-diffusivity D* were quantified. Independent samples t test of IVIM-derived metrics were conducted between benign and malignant nodules. Receiver-operating characteristic analyses were performed to determine the optimal thresholds as well as the sensitivity and specificity for differentiating. Significant intergroup difference was observed in ADC, D, D*, and f (p < 0.001). Malignant tumors featured significantly lower ADC, D and D* values and a higher f value than that of benign nodules. The ADC, D, and D* could distinguish the benign from malignant thyroid nodules, and parameter f differentiate the malignant tumors from benign nodules. The values of the area under the curve for parameter ADC, D, and D* were 0.784 (p = 0.001), 0.795 (p = 0.001), and 0.850 (p < 0.001), separately, of which the area under the curve of f value was the maximum for identifying the malignant from benign nodules, which was 0.841 (p < 0.001). This study suggested that ADC and IVIM-derived metrics, including D, D*, and f, could potentially serve as noninvasive predictors for the preoperative differentiating of thyroid nodules, and f value performed best in identifying the malignant from benign nodules among these parameters. Copyright © 2018 Academic Radiology. Published by Elsevier Inc. All rights reserved.

  2. Solitary pulmonary nodule and {sup 18}F-FDG PET/CT. Part 2: accuracy, cost-effectiveness, and current recommendations

    Energy Technology Data Exchange (ETDEWEB)

    Mosmann, Marcos Pretto; Borba, Marcelle Alves; Macedo, Francisco Pires Negromonte de; Liguori, Adriano de Araujo Lima; Villarim Neto, Arthur [Liga Norte-Riograndense Contra o Cancer, Natal, RN (Brazil); Lima, Kenio Costa de, E-mail: mosmann@gmail.com [Universidade Federal do Rio Grande do Norte (UFRN), Natal, RN (Brazil). Programa de Pos-Graduacao em Saude Coletiva

    2016-03-15

    A solitary pulmonary nodule is a common, often incidental, radiographic finding. The investigation and differential diagnosis of solitary pulmonary nodules remain complex, because there are overlaps between the characteristics of benign and malignant processes. There are currently many strategies for evaluating solitary pulmonary nodules. The main objective is to identify benign lesions, in order to avoid exposing patients to the risks of invasive methods, and to detect cases of lung cancer accurately, in order to avoid delaying potentially curative treatment. The focus of this study was to review the evaluation of solitary pulmonary nodules, to discuss the current role of {sup 18}F fluorodeoxyglucose positron-emission tomography, addressing its accuracy and cost-effectiveness, and to detail the current recommendations for the examination in this scenario. (author)

  3. Application of Sonoelastography in Differential Diagnosis of Benign and Malignant Thyroid Nodules.

    Science.gov (United States)

    Esfahanian, Fatemeh; Aryan, Arvin; Ghajarzadeh, Mahsa; Yazdi, Meisam Hosein; Nobakht, Nasir; Burchi, Mehdi

    2016-01-01

    Sonoelastography is a new ultrasound method which could be helpful to determine which thyroid nodule is malignant. We designed this study to evaluate the accuracy of sonoelastography in differentiating of benign and malignant thyroid nodules in Iranian patients. Forty thyroid nodules in forty consecutive patients who had been referred for sonography-guided fine-needle aspiration biopsy were evaluated. Gray scale ultrasound and elastosonography by real-time, freehand technique applied for all patients. Elastography findings were classified into four groups. Nodules which were classified as patterns 1 or 2 in elastogram evaluation were classified as benign and probably malignant if elastogram scans were patterns 3 and 4 of elastogram scan. Mean age ± standard deviation (SD) was 42.2 ± 12.6 years, and mean ± SD thyroid-stimulating hormone level was 1.4 ± 1.9 IU/ml. Thirty-five cases (87.5%) were female and 5 (12.5%) were male. Histological examination indicated 27 (67.5%) benign and 13 (32.5%) malignant nodules. The most elastogram score was 2 (50%) followed by score 3. The cut-off point of 2 considered as the best value to differentiate benign and malignant thyroid nodules with sensitivity and specificity of 61% and 78% (area under the curve = 0.76, 95% confidence interval: 0.6-0.92, P = 0.007). Sonoelastography could help to differentiate benign and malignant thyroid nodules. As our sample size was limited, larger studies are recommended.

  4. Role of Duplex Power Doppler Ultrasound in Differentiation between Malignant and Benign Thyroid Nodules

    International Nuclear Information System (INIS)

    Algin, Oktay; Algin, Efnan; Gokalp, Gokhan; Ocakog, Gokhan; Erdog an, Cuneyt; Saraydaroglu, Ozlem; Ercan Tuncel, Prof

    2010-01-01

    To evaluate the usage of duplex power Doppler ultrasound (PDUS) for the differentiation of benign and malignant thyroid nodules. We prospectively examined 77 thyroid nodules in 60 patients undergoing ultrasound-guided fine needle aspiration biopsy (FNAB). Each nodule was described according to size, inner structure, borders, parenchymal echogenicity, peripheral halo formation, and the presence of calcification (Bmode ultrasound findings). Vascularity as determined by PDUS imaging was defined as non-vascular, peripheral, central, or of mixed type. For each nodule, the pulsatility index (PI) and resistive index (RI) values were obtained. Results of FNAB and surgical pathological examination (if available) were used as a proof of final diagnosis to categorize all nodules as benign or malignant. A receiver operating characteristic (ROC) curve analysis was performed to establish cut-off, sensitivity, and specificity values associated with RI-PI values. A significant relationship was observed between malignancy and irregular margins, microcalcifications, and hypoechogenicity on ultrasound examination (p 0.05). The central, peripheral, and mean RI-PI values were higher in malignant nodules when compared to the other cytologies (p < 0.05). Vascularity is not a useful parameter for distinguishing malignant from benign thyroid nodules. However, RI and PI values are useful in distinguishing malignant from benign thyroid nodules

  5. Comparison of muscle-to-nodule and parenchyma-to-nodule strain ratios in the differentiation of benign and malignant thyroid nodules: Which one should we use?

    Energy Technology Data Exchange (ETDEWEB)

    Aydin, Ramazan, E-mail: raydin1984@hotmail.com [Department of Radiology, Samsun Education and Research Hospital, Samsun (Turkey); Elmali, Muzaffer, E-mail: muzafel@yahoo.com.tr [Department of Radiology, Ondokuz Mayis University, Faculty of Medicine, Samsun (Turkey); Polat, Ahmet Veysel, E-mail: veyselp@hotmail.com [Department of Radiology, Ondokuz Mayis University, Faculty of Medicine, Samsun (Turkey); Danaci, Murat, E-mail: danacim55@yahoo.com [Department of Radiology, Ondokuz Mayis University, Faculty of Medicine, Samsun (Turkey); Akpolat, Ilkser, E-mail: ilkserakpolat@yahoo.com [Department of Pathology, Ondokuz Mayis University, Faculty of Medicine, Samsun (Turkey)

    2014-03-15

    Objective: The aim of this study is to investigate the diagnostic accuracy of muscle-to-nodule strain ratio (MNSR) in the differentiation of benign and malignant thyroid nodules and to see if there was a difference between MNSR and parenchyma-to-nodule strain ratios (PNSR) in diagnosis. Methods: A total of 106 consecutive patients (88 women and 18 men; age range 19–79 years) with thyroid nodules were prospectively examined using ultrasound and sonoelastography before the fine-needle aspiration biopsy. The mean MNSR and PNSR were calculated for each nodule and the elasticity score was determined according to four-point scoring system. Results: According to the four-point scoring system, 44 of the 83 benign nodules had a score of one or two while 22 of the 23 malignant nodules had a score of three or four (p < 0.001). Using ROC analysis, the best cutoff point for MNSR 1.85 and for PNSR 3.14 was calculated. The sensitivity and specificity for the MNSR were 95.6%, 92.8%, respectively; for the PNSR were 95.6%, 93.4%, respectively, when the best cutoff points were used (p < 0.001). The κ value for the PNSR and MNSR methods was 0.87, which indicated an almost perfect agreement (p < 0.001). Conclusions: Sonoelastography has a high diagnostic accuracy in the differentiation of benign and malignant thyroid nodules. There was no significant difference between MNSR and PNSR in the differentiation of benign and malignant thyroid nodules. Therefore, we think that MNSR could safely be used in situations where PNSR could not be used.

  6. Detection of pulmonary metastatic nodules: usefulness of low-dose multidetector CT in comparison with chest radiograph

    International Nuclear Information System (INIS)

    Kim, Ki Nam; Lee, Ki Nam; Yang, Doo Kyung; Lee, Soo Keol

    2006-01-01

    We wanted to evaluate the usefulness of low-dose multidetector CT for the detection and follow-up of pulmonary metastatic nodules in patients suffering with malignancy. We retrospectively reviewed the conventional chest radiographs and low-dose multidetector CT (low-dose CT) scans of 81 patients who had been under the diagnosis of malignancy. We reviewed the detection of pulmonary nodules and we counted the number of nodules detected by each method. The nodules were confirmed by surgical operation and by the radiologic criteria. The accuracy, sensitivity, specificity and positive and negative predictive values of each method for detecting metastatic nodules were compared with χ 2 tests. Low-dose CT depicted more nodules than did chest radiograph, and the indeterminate nodules seen on chest radiograph may be clearly benign on low-dose CT (eg. calcified granulomas or bony lesions). The accuracy of low-dose CT (75.3%) was significantly higher than that of chest radiograph (49.4%) for the detection for metastatic nodules (ρ < 0.05). Low-dose CT may provide better information than does chest radiograph for diagnosing pulmonary metastasis

  7. Agile convolutional neural network for pulmonary nodule classification using CT images.

    Science.gov (United States)

    Zhao, Xinzhuo; Liu, Liyao; Qi, Shouliang; Teng, Yueyang; Li, Jianhua; Qian, Wei

    2018-04-01

    To distinguish benign from malignant pulmonary nodules using CT images is critical for their precise diagnosis and treatment. A new Agile convolutional neural network (CNN) framework is proposed to conquer the challenges of a small-scale medical image database and the small size of the nodules, and it improves the performance of pulmonary nodule classification using CT images. A hybrid CNN of LeNet and AlexNet is constructed through combining the layer settings of LeNet and the parameter settings of AlexNet. A dataset with 743 CT image nodule samples is built up based on the 1018 CT scans of LIDC to train and evaluate the Agile CNN model. Through adjusting the parameters of the kernel size, learning rate, and other factors, the effect of these parameters on the performance of the CNN model is investigated, and an optimized setting of the CNN is obtained finally. After finely optimizing the settings of the CNN, the estimation accuracy and the area under the curve can reach 0.822 and 0.877, respectively. The accuracy of the CNN is significantly dependent on the kernel size, learning rate, training batch size, dropout, and weight initializations. The best performance is achieved when the kernel size is set to [Formula: see text], the learning rate is 0.005, the batch size is 32, and dropout and Gaussian initialization are used. This competitive performance demonstrates that our proposed CNN framework and the optimization strategy of the CNN parameters are suitable for pulmonary nodule classification characterized by small medical datasets and small targets. The classification model might help diagnose and treat pulmonary nodules effectively.

  8. Multiple Pulmonary Nodules in an Immunocompetent Adolescent with Infectious Mononucleosis.

    Science.gov (United States)

    Bhaskaran, Praveena Nediyara; Puliyel, Mammen; Myers, Melissa; Abughali, Nazha

    2018-02-15

    Infectious mononucleosis is usually a self-limiting illness, but can be rarely associated with complications. A 17-year-old boy with Epstein-Barr virus related infectious mononucleosis and cold antibody-mediated autoimmune hemolytic anemia with incidentally noted multiple pulmonary nodules. Nodules regressed over the next few weeks without specific therapy. Pediatricians need to be aware of this rare clinical presentation of infectious mononucleosis so that further invasive testing can be avoided.

  9. Mucoid impaction presenting as multiple pulmonary nodules in cystic fibrosis

    International Nuclear Information System (INIS)

    Carpenter, L.D.; Lambie, N.K.; Wilsher, M.L.

    1996-01-01

    Mucoid impaction has been described as a complication of asthma and more commonly in patients with allergic bronchopulmonary aspergillosis. In such cases, the impacted pools of mucus may present as discrete nodules on chest X-ray and hence simulate the appearance of metastatic malignancy. A case of mucoid impaction presenting as multiple pulmonary nodules in a patient with cystic fibrosis is described. The chest X-ray showed hyperinfiltration and scattered changes consistent with bronchiectasis. Computed tomography scan confirmed these and additional intra-pulmonary nodular densities. This report illustrates that mucus impaction as a cause of pulmonary nodules should be considered in any patient with chronic lung disease characterised by excess mucus production. 6 refs., 3 figs

  10. Giant Cell Tumor of the Thoracic Spine Presenting as a Posterior Mediastinal Tumor with Benign Pulmonary Metastases: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Hun [Daegu Fatima Hospital College of Medicine, Daegu (Korea, Republic of); Rho, Byung Hak; Bahn, Young Eun; Choi, Won Il [Dongsan Medical Center, Keimyung University School of Medicine, Daegu (Korea, Republic of)

    2010-11-15

    Giant cell tumor of bone is a benign, but potentially aggressive lesion that can show local recurrence and metastases. We report here on a case of a 29-year-old man who presented with an incidentally found mediastinal mass. Chest radiography and computed tomography showed a huge mediastinal mass with bilateral pulmonary nodules and the diagnosis of giant cell tumor with benign pulmonary metastasis was confirmed. To the best of our knowledge, this is the first reported case of primary thoracic spinal giant cell tumor manifesting as a huge mediastinal mass with pulmonary metastases

  11. Virtual touch tissue quantifications in the differential diagnosis of benign and malignant thyroid nodules

    International Nuclear Information System (INIS)

    Ha, Seung Mi; Cho, Seong Whi

    2016-01-01

    The aim of this study was to evaluate the diagnostic utility of the virtual touch tissue quantification (VTQ) technology for differentiating between benign and malignant thyroid nodules. 198 nodules (168 benign and 30 malignant nodules) identified in 164 patients with available VTQ velocity data and fine-needle aspiration cytology or post-surgical pathological results were included. The VTQ velocities of nodules and adjacent thyroid tissue were examined. Malignant nodules had a significantly higher VTQ velocity (3.06 ± 1.04 m/s, range: 1.90-6.46 m/s) than that of benign nodules (2.40 ± 0.85 m/s, range: 0.69-8.09 m/s) (p = 0.002). The VTQ velocity ratio between malignant nodules and adjacent thyroid tissue (1.39 ± 0.43, range: 0.89-2.65) was also statistically higher than that of benign nodules (1.15 ± 0.44, range: 0.26-3.47) (p = 0.008). The area under the receiver operating characteristic curve for the VTQ velocity was 0.72 with a cutoff point of 2.37 m/s and that of the VTQ velocity ratio was 0.68 with a cutoff point of 1.26. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy for the VTQ velocity were 86.7%, 50.6%, 23.9%, 95.5%, and 56.1%, respectively and 60.0%, 72.0%, 27.7%, 91.0%, and 70.2%, respectively for the VTQ velocity ratio. VTQ may be helpful in differentiating malignant and benign thyroid nodules with high negative predictive value

  12. Virtual touch tissue quantifications in the differential diagnosis of benign and malignant thyroid nodules

    Energy Technology Data Exchange (ETDEWEB)

    Ha, Seung Mi; Cho, Seong Whi [Dept. of Radiology, Kangwon National University Hospital, Chuncheon (Korea, Republic of)

    2016-06-15

    The aim of this study was to evaluate the diagnostic utility of the virtual touch tissue quantification (VTQ) technology for differentiating between benign and malignant thyroid nodules. 198 nodules (168 benign and 30 malignant nodules) identified in 164 patients with available VTQ velocity data and fine-needle aspiration cytology or post-surgical pathological results were included. The VTQ velocities of nodules and adjacent thyroid tissue were examined. Malignant nodules had a significantly higher VTQ velocity (3.06 ± 1.04 m/s, range: 1.90-6.46 m/s) than that of benign nodules (2.40 ± 0.85 m/s, range: 0.69-8.09 m/s) (p = 0.002). The VTQ velocity ratio between malignant nodules and adjacent thyroid tissue (1.39 ± 0.43, range: 0.89-2.65) was also statistically higher than that of benign nodules (1.15 ± 0.44, range: 0.26-3.47) (p = 0.008). The area under the receiver operating characteristic curve for the VTQ velocity was 0.72 with a cutoff point of 2.37 m/s and that of the VTQ velocity ratio was 0.68 with a cutoff point of 1.26. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy for the VTQ velocity were 86.7%, 50.6%, 23.9%, 95.5%, and 56.1%, respectively and 60.0%, 72.0%, 27.7%, 91.0%, and 70.2%, respectively for the VTQ velocity ratio. VTQ may be helpful in differentiating malignant and benign thyroid nodules with high negative predictive value.

  13. Ultrasound-guided microwave ablation in the treatment of benign thyroid nodules in 435 patients.

    Science.gov (United States)

    Liu, Yu-Jiang; Qian, Lin-Xue; Liu, Dong; Zhao, Jun-Feng

    2017-09-01

    The objective of the present study was to investigate the effectiveness and safety of ultrasound-guided microwave ablation in the treatment of benign thyroid nodules. A total of 474 benign thyroid nodules in 435 patients who underwent ultrasound-guided microwave ablation from September 2012 to August 2015 were included. Nodule volume and thyroid function were measured before treatment and at 1, 3, 6, and 12 months and subsequently after every 6 months. The nodule volume reduction rate and changes of thyroid function were evaluated. The volume of all thyroid nodules significantly decreased after ultrasound-guided microwave ablation. The average volume was 13.07 ± 0.95 ml before treatment, and 1.14 ± 0.26 ml at 12-months follow-up. The mean volume reduction rate was 90% and the final volume reduction rate was 94%. The volume reduction rate of mainly cystic nodules was significantly higher than that of simple solid and mainly solid nodules (all P microwave ablation is an effective and safe technique for treatment of benign thyroid nodules, and has the potential for clinical applications. Impact statement Ultrasound-guided MWA is an effective and safe technique for the treatment of benign thyroid nodules. It can significantly reduce the nodule volume, improve the patients' clinical symptoms, has less complication, guarantees quick recovery, meets patients' aesthetic needs, and shows less interference on the physiological and psychological aspects of the body. MWA should be a good complement to traditional open surgery and has potentials in clinical applications.

  14. 应用计算机人工神经网络系统结合CT与PET鉴别良、恶性肺结节%Computerized distinction of benign and malignant pulmonary nodules on PET and CT with an artificial neural network

    Institute of Scientific and Technical Information of China (English)

    聂永康; 赵绍宏; 王瑞民; 吴坚; 蔡祖龙; 杨立

    2011-01-01

    目的 利用肺结节CT、PET特征,开发计算机人工神经网络(ANN)辅助诊断系统,评价其对肺结节良恶性的鉴别能力.方法 连续收集112例肺内单发小结节(<3.0 cm)患者,均接受PET/CT及胸部CT检查,二者间隔小于1个月.112例患者中恶性肺结节52例,良性60例,均经组织学或临床随诊证实.利用结节的CT特征及PET特征开发计算机ANN辅助诊断系统.计算机ANN的训练及测试采用Round-Robin方法.采用ROC方法评价计算机ANN输出结果并进行统计学分析.结果 CT计算机ANN程序采用20个输入单元,包括4个临床特征及16个CT特征,ROC曲线下面积(Az)为0.83;PET计算机ANN程序采用4个临床特征及1个PET特征作为5个输入单元,Az值为0.91;CT+PET计算机ANN程序采用临床特征CT及PET所有21个输入单元.Az值为0.95.与CT计算机ANN程序、PET计算机ANN程序相比,CT+PET计算机ANN程序输出结果明显提高(p=0.015、0.037).结论 CT+PET ANN计算机辅助诊断程序输出结果优于单纯PET或CT计算机ANN结果.当PET对肺结节诊断有困难时,结节的CT特征有助于鉴别诊断.%Objective To develop computer-aided diagnostic system using artificial neural network (ANN) method which integrates pulmonary nodule features on CT image with that on PET image for differentiating malignancy from benign pulmonary nodules.Methods Totally 112 consecutive patients with pulmonary nodules (<3.0 cm) underwent both thoracic CT and whole-body PET/CT.The interval between CT and PET examinations was less than 1 month.There were 52 malignant and 60 benign lesions confirmed with pathology or clinical follow-up.ANN was used for differentiating benign from malignant nodules based on clinical information together with CT and PET features.Round-Robin method was applied for training and testing the ANN.The output from the computerized schemes were evaluated with receiver operating characteristic (ROC) analysis.Results When 20 input units including 4

  15. Correlation between the Quantifiable Parameters of Whole Solitary Pulmonary Nodules Perfusion Imaging Derived with Dynamic CT and Nodules Size

    Directory of Open Access Journals (Sweden)

    Shiyuan LIU

    2009-05-01

    Full Text Available Background and objective The solitary pulmonary nodules (SPNs is one of the most common findings on chest radiographs. The blood flow patterns of the biggest single SPNs level has been studied. This assessment may be only a limited sample of the entire region of interest (ROI and is unrepresentative of the SPNs as a volume. Ideally, SPNs volume perfusion should be measured. The aim of this study is to evaluate the correlation between the quantifiableparameters of SPNs volume perfusion imaging derived with 16-slice spiral CT and 64-slice spiral CT and nodules size. Methods Sixty-five patients with SPNs (diameter≤3 cm; 42 malignant; 12 active inflammatory; 11 benign underwent multi-location dynamic contrast material-enhanced serial CT scanning mode with stable table were performed; The mean values of valid sections were calculated, as the quantifiable parameters of volume SPNs perfusion imaging derived with16-slice spiral CT and 64-slice spiral CT. The correlation between the quantifiable parameters of SPNs volume perfusion imaging derived with 16-slice spiral CT and 64-slice spiral CT and nodules size were assessed by means of linear regression analysis. Results No significant correlations were found between the nodules size and each of the peak height (PHSPN (32.15 Hu±14.55 Hu,ratio of peak height of the SPN to that of the aorta (SPN-to-A ratio(13.20±6.18%, perfusion(PSPN (29.79±19.12 mLmin-1100 g-1 and mean transit time (12.95±6.53 s (r =0.081, P =0.419; r =0.089, P =0.487; r =0.167, P =0.077; r =0.023, P =0.880. Conclusion No significant correlations were found between the quantifiable parameters of SPNs volume perfusion imaging derived with 16-slice spiral CT and 64-slice spiral CT and nodules size.

  16. Diffusion-weighted MR imaging and ADC mapping in differentiating benign from malignant thyroid nodules

    International Nuclear Information System (INIS)

    Khizer, A.T.; Slehria, A.U.R.

    2015-01-01

    To determine the diagnostic accuracy of Diffusion-Weighted Imaging (DWI) and Apparent Diffusion Coefficient (ADC) mapping in differentiating benign from malignant thyroid nodules by taking histopathology as the gold standard. Study Design:Across-sectional analytical study. Place and Duration of Study: Department of Radiology at Combined Military Hospital (CMH), Lahore, from August 2012 to July 2013. Methodology: Thirty-five patients, who were referred to radiology department of CMH, Lahore, for ultrasound or Fine Needle Aspiration Cytology (FNAC) of thyroid gland, fulfilling the inclusion and exclusion criteria, were included in the study. They were evaluated on 1.5 Tesla MRI machine with T1- and T2-weighted imaging as well as fat-suppressed technique. DWI was done using b-values of 0 and 1000 s/mm2 and ADC values were calculated for the thyroid nodules. All of these patients were subjected to ultrasound guided core biopsy and histopathology results were correlated with ADC values. Results: The benign nodules showed facilitated diffusion while malignant nodules showed restricted diffusion. T-test was used to assess the difference in mean ADC values between benign and malignant nodules. The mean ADC value of the malignant thyroid nodules (0.94 ± 0.16 x 10/sup -3/mm2/s) was significantly lower than that of the benign thyroid nodules (1.93 ±0.13 x 10/sup -3/mm2/s) (p-value < 0.05). ADC value of 1.6 x 10/sup -3/mm2/s was used as a cut-off, for differentiating benign from malignant thyroid nodules. The sensitivity, specificity, PPV, NPV and diagnostic accuracy of DWI and ADC values in differentiating benign from malignant thyroid nodules were 93%, 95%, 93%, 95% and 92.3%, respectively. Conclusion: DWI is a non-invasive diagnostic tool for characterization and differentiation between benign and malignant thyroid nodules. It not only decreases the burden of unnecessary surgeries when pre-operative FNAC and biopsy are inconclusive, but is also helpful in reaching a

  17. Ultrasonographic Findings of the Prostatic Disease : Comparative Analysis of the Benign and Malignant Nodules

    International Nuclear Information System (INIS)

    Song, Yun Gyu; Kim, Ji Yang; Lee, Su Han; Kong, Su Jin; Sung, Young Soon; Kwon, Jae Soo

    1996-01-01

    We evaluated the characteristics of the benign and malignant nodules on transrectal ultrasound in diagnosis of prostatic disease. Histologic examination of the trans perineal prostatic biopsy of the total 47 cases resulted in 19 cases of BPH, 8 cases of prostatic cancer, and 20 cases of normal prostatic tissue group. The hypoechoic mass in peripheral zone on TRUS had high possibility of prostatic carcinoma and the isoechoic or mixed echogenic mass in central gland had high possibility of benign lesion. Hypoechoic haloes around nodules and cysts were noted in BPH and normal prostatic tissue group, that were compatible with benign lesion. The mean value of PSA was 12.0 ng/ ml in BPH, 8.5 ng / ml in normal prostatic tissue group, and 65.6 ng / ml in prostatic cancer, which was very high in prostatic cancer. Between BPH and normal prostatic tissue group, there was no demonstrable difference in location of nodule, pattern of calcification, and echogenicity of the nodules on TRUS. The size of prostatic gland was relatively smaller and mean value of PSA was lower in normal prostatic tissue group, compared with in BPH. In conclusion, the location of the nodules and PSA value are considered to be important in differentiation of the benign and malignant prostatic nodules

  18. Benign versus malignant solid nodules in subareolar area of the breast: Radiological, clinical and pathological correlation

    International Nuclear Information System (INIS)

    Je, Bo Kyung; Seo, Bo Kyoung; Lee, Nam Joon; Jeon, Hae Jeong; Park, Jeong Hee; Cho, Kyu Ran; Lee, Ji Young; Choi, Eun Jeong; Lee, June Young; Kim, In Sun; Kim, Seok Jin

    2003-01-01

    To investigate the general applicability of ultrasonography (US) and clinical findings in differentiating benign from malignant solid nodules in the subareolar area of the breast. From March 2001 to March 2003, pathologically proven 84 nodules from 78 patients were included in this study. Two radiologists evaluated the shape, margins, internal echotexture, internal echogenicity, posterior echo intensity and relation with the major ducts, and each nodule was then classified as benign or malignant. Clinical findings were divided into either or absence of symptom. The ultrasonographic, mammographic and clinical classifications were compared with the pathological results. The sensitivity (SE), specificity (SP), positive predictive values (PPV) and negative predictive values (NPV) were calculated for ultrasonographic, mammographic and clinical classifications. Sixteen nodules were proved to be malignant (7 ductal carcinoma in situ and 9 invasive ductal carcinoma), and the remaining 68 nodules were benign. SE, SP, PPV, and NPV of breast cancer according to the ultrasonographical classification were 100%, 61.8%, 38.1% and 100% while those of the clinical classification were 81.3%, 73.5%, 41.9% and 94.3%, respectively. Relation with the major ducts such as ductal communication or intraductal location demonstrated a high SE (87.5%) and NPV (92.0%). Ultrasonographic and clinical findings can be helpful in the differentiation of benign solid nodules from malignant lesions in the subareolar area of the breast.

  19. Dual time point FDG PET imaging in evaluating pulmonary nodules with low FDG avidity

    International Nuclear Information System (INIS)

    Chen Xiang; Zhao Jinhua; Song Jianhua; Xing Yan; Wang Taisong; Qiao Wenli

    2010-01-01

    A standardized uptake value (SUV) of 2.5 is frequently used as criteria to evaluate pulmonary lesions. However, false results may occur. Some studies have shown the usefulness of delayed PET for improving accuracy, while others recently have shown fewer promising results. This study was designed to investigate the accuracy of dual time point (DTP) FDG PET imaging in the evaluation of pulmonary lesions with an initial SUV less than 2.5. DTP FDG PET studies were conducted about 1 and 2 hours after FDG injection, and pulmonary lesions with an initial SUV less than 2.5 were identified. Nodules with pathologic results or imaging follow up were included. The differences in SUV and retention index (RI) between benign and malignant pulmonary lesions were analyzed. Receiver operating characteristics (ROC) analysis was performed to evaluate the discriminating validity of SUV and RI. 51 lesions were finally included. A RI greater than 0% was observed in 64% of the benign lesions; 56% had a RI greater than 10%. Among the malignancies, 80.8% had a RI greater than 0%, and 61.5% had a RI greater than 10%. We found no significant differences in SUV and RI between benign and malignant lesions. The area under the ROC curve did not differ from 0.5 whether using SUV or the retention index. Utilizing a SUV increase of 10%, the sensitivity was 61.5%, specificity 44% and accuracy was 52.9%. Dual time point FDG PET may not be of benefit in the evaluation of pulmonary nodules with low FDG avidity. (authors)

  20. Positron emission tomography of incidentally detected small pulmonary nodules

    DEFF Research Database (Denmark)

    Fischer, B M; Mortensen, J; Dirksen, A

    2004-01-01

    The aim of this study was to assess the value of fluorodeoxyglucose positron emission tomography (FDG PET) imaging of small pulmonary nodules incidentally detected by spiral computed tomography (CT) in a high-risk population. Ten patients (five females, five males, aged 54-72 years) were recruited...

  1. Application of artificial neural networks in the CT study of solitary pulmonary nodule

    International Nuclear Information System (INIS)

    Wang Xiaohua; Ma Daqing; Chen Hui; Gao Peiyi; Zhou Xinhua

    2006-01-01

    Objective: To establish a new-type discriminative method in differentiating benign from malignant solitary pulmonary nodule (SPN) on high-resolution CT/thin-section CT by using artificial neural networks theory in the CT diagnostic study of SPN. Methods: Two hundred SPNs pathologically proved by operation or biopsy (primary pulmonary carcinoma 135 eases, benign nodules 65 cases) were collected, 3 clinical characteristics (age, sex, with or without bloody sputum) and 9 high-resolution CT/thin-section CT characteristics (location, long and short diameter, contour, spiculation, halo sign, air-space, relation with the adjacent blood vessels and pleura) were analyzed. 140 cases were randomly selected to form the training samples, on which artificial neural networks model (BP networks) was built and compared with Logistic model from Statistical Package for the Social Science (SPSS) software. Results: The total consistent rate of BP neural networks (98.0%, 196/200) was higher than that of Logistic model (86.0%, 172/200) (P<0.001). Areas under ROC curve were 0.996±0.004 and 0.936±0.017, respectively, and the difference between the two was significant (P<0.001). Conclusion: Using high-resolution CT and thin-section CT in combination with artificial neural networks theory is feasible, and it is expected to become a useful and reliable clinical tool in differentiating benign from malignant SPN. (authors)

  2. Benign thyroid nodule unresponsive to radiofrequency ablation treated with laser ablation: a case report.

    Science.gov (United States)

    Oddo, Silvia; Balestra, Margherita; Vera, Lara; Giusti, Massimo

    2018-05-11

    Radiofrequency ablation and laser ablation are safe and effective techniques for reducing thyroid nodule volume, neck symptoms, and cosmetic complaints. Therapeutic success is defined as a nodule reduction > 50% between 6 and 12 months after the procedure, but a percentage of nodules inexplicably do not respond to thermal ablation. We describe the case of a young Caucasian woman with a solid benign thyroid nodule who refused surgery and who had undergone radiofrequency ablation in 2013. The nodule did not respond in terms of either volume reduction or improvement in neck symptoms. After 2 years, given the patient's continued refusal of thyroidectomy, we proposed laser ablation. The nodule displayed a significant volume reduction (- 50% from radiofrequency ablation baseline volume, - 57% from laser ablation baseline), and the patient reported a significant improvement in neck symptoms (from 6/10 to 1/10 on a visual analogue scale). We conjecture that some benign thyroid nodules may be intrinsically resistant to necrosis when one specific ablation technique is used, but may respond to another technique. To the best of our knowledge, this is the first description of the effect of performing a different percutaneous ablation technique in a nodule that does not respond to radiofrequency ablation.

  3. Predictive factors for malignancy in incidental pulmonary nodules detected in breast cancer patients at baseline CT

    Energy Technology Data Exchange (ETDEWEB)

    Hammer, Mark M.; Mortani Barbosa, Eduardo J. [University of Pennsylvania, Division of Cardiothoracic Imaging, Department of Radiology, Perelman School of Medicine, Philadelphia, PA (United States)

    2017-07-15

    Pulmonary nodules are commonly encountered at staging CTs in patients with extrathoracic malignancies, but their significance on a per-patient basis remains uncertain. We undertook a retrospective analysis of pulmonary nodules identified in patients with a diagnosis of breast cancer from 2010 - 2015, evaluating nodules present at a baseline CT (i.e. prevalent nodules). We reviewed 211 patients with 248 individual nodules. The rate of malignancy in prevalent nodules is low, approximately 13 %. Variables associated with metastasis include pleural studding, hilar lymphadenopathy and the presence of extrapulmonary metastasis, as well as number of nodules, nodule size and nodule shape. Using a combination of these factors, we have developed an evidence-based multivariate decision tree to predict which nodules are malignant in these patients, which is 91 % accurate and 100 % sensitive for metastasis. We propose a simplified clinical prediction algorithm to guide radiologists and oncologists in managing patients with breast cancer and incidental pulmonary nodules. (orig.)

  4. Computed tomographic fluoroscopy-guided transthoracic needle biopsy for diagnosis of pulmonary nodules

    International Nuclear Information System (INIS)

    Hirose, Takashi; Mori, Kiyoshi; Machida, Suguru; Tominaga, Keigo; Yokoi, Kohei; Adachi, Mitsuru

    2000-01-01

    The purpose of this study was to evaluate the usefulness of computed tomographic (CT) fluoroscopy-guided transthoracic needle biopsy (TTNB) with an 18-gauge automatic biopsy gun for the diagnosis of pulmonary nodules. Between March 1996 and January 1998, 50 patients in whom pulmonary lesions could not be diagnosed cytopathologically with fiberoptic bronchoscopy or were not clearly visualized with fluoroscopy underwent CT fluoroscopy-guided TTNB. Final pathological diagnoses were 23 lung carcinomas, five pulmonary metastases and 22 benign lesions. Sufficient tissue for analysis was obtained from 48 of the 50 lesions (96%). The overall diagnostic yield of CT fluoroscopy-guided TTNB was 90%. The sensitivity, specificity and accuracy for malignancy were 89%, 100% and 94%, respectively. In 20 of the 22 cases (91%) of benign lesions, histological analysis yielded correct and specific diagnoses. Complications occurred in 22 of the 50 cases (44%). The most common complication was pneumothorax, which occurred in 21 of the 50 cases (42%). Chest tube insertion was required in 6 (12%). Although CT fluoroscopy could not decrease the complication rate, CT fluoroscopy-guided TTNB with an automatic biopsy gun appears to be a promising technique for diagnosing pulmonary lesions, particularly benign lesions. (author)

  5. CT-Guided Percutaneous Transthoracic Localization of Pulmonary Nodules Prior to Video-Assisted Thoracoscopic Surgery Using Barium Suspension

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Nyoung Keun; Park, Chang Min; Kang, Chang Hyun; Jeon, Yoon Kyung; Choo, Ji Yung; Lee, Hyun Ju; Goo, Jin Mo [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2012-11-15

    To describe our initial experience with CT-guided percutaneous barium marking for the localization of small pulmonary nodules prior to video-assisted thoracoscopic surgery (VATS). From October 2010 to April 2011, 10 consecutive patients (4 men and 6 women; mean age, 60 years) underwent CT-guided percutaneous barium marking for the localization of 10 small pulmonary nodules (mean size, 7.6 mm; range, 3-14 mm): 6 pure ground-glass nodules, 3 part-solid nodules, and 1 solid nodule. A 140% barium sulfate suspension (mean amount, 0.2 mL; range, 0.15-0.25 mL) was injected around the nodules with a 21-gauge needle. The technical details, surgical findings and pathologic features associated with barium localizations were evaluated. All nodules were marked within 3 mm (mean distance, 1.1 mm; range, 0-3 mm) from the barium ball (mean diameter, 9.6 mm; range, 8-16 mm) formed by the injected barium suspension. Pneumothorax occurred in two cases, for which one needed aspiration. However, there were no other complications. All barium balls were palpable during VATS and visible on intraoperative fluoroscopy, and were completely resected. Both the whitish barium balls and target nodules were identifiable in the frozen specimens. Pathology revealed one invasive adenocarcinoma, five adenocarcinoma-in-situ, two atypical adenomatous hyperplasias, and two benign lesions. In all cases, there were acute inflammations around the barium balls which did not hamper the histological diagnosis of the nodules. CT-guided percutaneous barium marking can be an effective, convenient and safe pre-operative localization procedure prior to VATS, enabling accurate resection and diagnosis of small or faint pulmonary nodules.

  6. CT-Guided Percutaneous Transthoracic Localization of Pulmonary Nodules Prior to Video-Assisted Thoracoscopic Surgery Using Barium Suspension

    International Nuclear Information System (INIS)

    Lee, Nyoung Keun; Park, Chang Min; Kang, Chang Hyun; Jeon, Yoon Kyung; Choo, Ji Yung; Lee, Hyun Ju; Goo, Jin Mo

    2012-01-01

    To describe our initial experience with CT-guided percutaneous barium marking for the localization of small pulmonary nodules prior to video-assisted thoracoscopic surgery (VATS). From October 2010 to April 2011, 10 consecutive patients (4 men and 6 women; mean age, 60 years) underwent CT-guided percutaneous barium marking for the localization of 10 small pulmonary nodules (mean size, 7.6 mm; range, 3-14 mm): 6 pure ground-glass nodules, 3 part-solid nodules, and 1 solid nodule. A 140% barium sulfate suspension (mean amount, 0.2 mL; range, 0.15-0.25 mL) was injected around the nodules with a 21-gauge needle. The technical details, surgical findings and pathologic features associated with barium localizations were evaluated. All nodules were marked within 3 mm (mean distance, 1.1 mm; range, 0-3 mm) from the barium ball (mean diameter, 9.6 mm; range, 8-16 mm) formed by the injected barium suspension. Pneumothorax occurred in two cases, for which one needed aspiration. However, there were no other complications. All barium balls were palpable during VATS and visible on intraoperative fluoroscopy, and were completely resected. Both the whitish barium balls and target nodules were identifiable in the frozen specimens. Pathology revealed one invasive adenocarcinoma, five adenocarcinoma-in-situ, two atypical adenomatous hyperplasias, and two benign lesions. In all cases, there were acute inflammations around the barium balls which did not hamper the histological diagnosis of the nodules. CT-guided percutaneous barium marking can be an effective, convenient and safe pre-operative localization procedure prior to VATS, enabling accurate resection and diagnosis of small or faint pulmonary nodules.

  7. 99mTc-EDDA/HYNIC-TOC scintigraphy in the differential diagnosis of solitary pulmonary nodules.

    Science.gov (United States)

    Płachcińska, Anna; Mikołajczak, Renata; Maecke, Helmut R; Michalski, Andrzej; Rzeszutek, Katarzyna; Kozak, Józef; Kuśmierek, Jacek

    2004-07-01

    Forty-three consecutive patients with solitary pulmonary nodules (SPNs) on chest radiographs were studied scintigraphically after administration of the somatostatin analogue (99m)Tc-EDDA/HYNIC-TOC. The objective of the study was to assess the usefulness of the procedure for differentiation of SPNs as malignant or benign. The administered activity was 740-925 MBq, and a single-photon emission computed tomography imaging technique was employed. Verification of the nodule aetiology was based on histology or cytology and bacteriology. A stable tumour size on chest radiography for at least 3 years was accepted as an additional criterion of benignity. In 29 patients, nodules were found to be malignant. The diagnoses included ten adenocarcinomas, five squamous cell carcinomas, two large cell carcinomas, six non-small cell lung cancers without specification of the more detailed morphology, two small cell lung cancers, two typical carcinoids and two metastatic tumours (leiomyosarcoma and malignant melanoma). In 14 patients the following benign tumours were diagnosed: four tuberculomas, one other granuloma, three hamartomas, one non-specific inflammatory infiltrate, one abscess, one peripheral carcinoid with the morphological characteristics of a benign tumour, one ectopic lesion of thyroid tissue and two benign tumours of unspecified aetiology with a stable size over 3 and 5 years respectively. Positive scintigraphic results were obtained in 26 of the 29 patients (90%) with malignant SPNs; among these, 24 of the 25 (96%) cases of primary pulmonary carcinoma yielded positive results. The remaining two false negative cases were the metastatic tumours, liposarcoma and melanoma. Of the 14 benign lesions, ten (71%) did not accumulate the radiopharmaceutical. The remaining four benign tumours that were visible on scintigrams comprised one tuberculoma, one hamartoma, one abscess and one case in which the diagnosis could not be established (the tumour had a stable size over 3 years

  8. 99mTc-EDDA/HYNIC-TOC scintigraphy in the differential diagnosis of solitary pulmonary nodules

    International Nuclear Information System (INIS)

    Plachcinska, Anna; Kusmierek, Jacek; Mikolajczak, Renata; Maecke, Helmut R.; Michalski, Andrzej; Rzeszutek, Katarzyna; Kozak, Jozef

    2004-01-01

    Forty-three consecutive patients with solitary pulmonary nodules (SPNs) on chest radiographs were studied scintigraphically after administration of the somatostatin analogue 99m Tc-EDDA/HYNIC-TOC. The objective of the study was to assess the usefulness of the procedure for differentiation of SPNs as malignant or benign. The administered activity was 740-925 MBq, and a single-photon emission computed tomography imaging technique was employed. Verification of the nodule aetiology was based on histology or cytology and bacteriology. A stable tumour size on chest radiography for at least 3 years was accepted as an additional criterion of benignity. In 29 patients, nodules were found to be malignant. The diagnoses included ten adenocarcinomas, five squamous cell carcinomas, two large cell carcinomas, six non-small cell lung cancers without specification of the more detailed morphology, two small cell lung cancers, two typical carcinoids and two metastatic tumours (leiomyosarcoma and malignant melanoma). In 14 patients the following benign tumours were diagnosed: four tuberculomas, one other granuloma, three hamartomas, one non-specific inflammatory infiltrate, one abscess, one peripheral carcinoid with the morphological characteristics of a benign tumour, one ectopic lesion of thyroid tissue and two benign tumours of unspecified aetiology with a stable size over 3 and 5 years respectively. Positive scintigraphic results were obtained in 26 of the 29 patients (90%) with malignant SPNs; among these, 24 of the 25 (96%) cases of primary pulmonary carcinoma yielded positive results. The remaining two false negative cases were the metastatic tumours, liposarcoma and melanoma. Of the 14 benign lesions, ten (71%) did not accumulate the radiopharmaceutical. The remaining four benign tumours that were visible on scintigrams comprised one tuberculoma, one hamartoma, one abscess and one case in which the diagnosis could not be established (the tumour had a stable size over 3 years

  9. Volumetry of Artificial Pulmonary Nodules in Ex Vivo Porcine Lungs: Comparison of Semi-automated Volumetry and Radiologists' Performance

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Ju Hyeon; Kim, Jin Hwan; Kim, Song Soo [Chungnam National University Hospital, Daejeon (Korea, Republic of); Jeon, Ho Sang [Pusan National University Yangsan Hospital, Yangsan (Korea, Republic of); Lee, Hyun Ju [Seoul National University Hospital, Seoul (Korea, Republic of); Park, Noh Hyuck [Kwandong University College of Medicine, Myungji Hospital, Goyang (Korea, Republic of); Cho, Gyu Seong [KAIST, Daejeon (Korea, Republic of)

    2010-10-15

    With the advent of MSCT, the detection rate of small pulmonary nodules is markedly greater. However, there is no definite diagnostic clue to differentiate between malignant and benign nodules, except for the interval growth in small nodule less than 1 cm in diameter. We evaluated the accuracy of computer aided volumetry (CAV) and compared it with 4 radiologists' measurement. Fifteen artificial nodules that were embedded in the ex vivo porcine lung were scanned by MSCT. The diameters and volumes of nodules were independently measured three times, at 5-day intervals, and by four radiologists as well as by CAV. We evaluated the accuracy of the measurements on the basis of the true diameter and volume of the nodules. Using a paired t-test and a Bland-Altman plot, we evaluated whether there was a statistically significant difference between the radiologists' measurements and the CAV. The accuracy of the manual measurements by radiologists revealed a statistically significant difference from the true diameter and volume of the artificial nodules (p<0.01). Conversely, the accuracy of CAV did not show a statistically significant difference with the true nodule diameter and volume (p>0.01) The results of this study suggest that CAV is an accurate and useful tool to evaluate the volume of pulmonary nodules and can eventually be used to differentiate malignant and benign nodules as well as evaluate the therapeutic response of lung cancer.

  10. Value of Quantitative Three-dimensional Doppler Ultrasound in the Differentiation of Benign and Malignant Thyroid Nodules.

    Science.gov (United States)

    Li, Wen-Bo; Zhang, Bo; Jiang, Yu-Xin; Zhu, Qing-Li; Zhang, Qing; Sun, Jian

    2015-06-01

    To investigate the role of quantitative three-dimensional (3D) power Doppler ultrasound in differentiating malignant and benign thyroid nodule. A total of 92 lesions in 86 patients were preoperatively examined using 3D power Doppler ultrasound. The Virtual Organ Computer-aided Analysis(VOCAL)-imaging program was used to analyze the stored volume ultrasound. The differences in the mean gray value (MG), vascularization index (VI), flow index(FI), and vascularization flow index (VFI) were compared between benign and malignant lesions. The MG of the malignant thyroid nodules was significantly lower than that of the benign ones (28.27±7.21 vs. 32.89±8.73,P=0.007). The benign nodules had significantly higher VI,FI,and VFI than the malignant nodules [VI:(40.43±26.55)% vs. (26.87±23.06)%,P=0.011;FI:41.03±7.19 vs. 37.51±7.17,P=0.022;VFI:18.23±14.60 vs. 11.47±12.47, P=0.009]. Also,76.5% (39/51) of the malignant nodules and 92.7% (38/41) of the benign nodules had higher VIs in the shell of the lesion than that of the whole lesion,and 80.4%(41/51) of the malignant nodules and 95.1% (39/41) of the benign nodules had higher FIs in the shell of the lesion than that of the whole lesion. Quantitative 3D power Doppler ultrasound provides a useful tool in distinguishing benign and malignant thyroid nodules. The malignant thyroid nodules have lower echoes than the benign nodules, wherese the benign nodules have larger blood flow than the malignant nodules.

  11. Pulmonary hyalinizing granuloma: Bilateral pulmonary nodules associated with chronic idiopathic thrombocytopenic purpura

    International Nuclear Information System (INIS)

    Satti, Mohamed B.; Batouk, Abdelnasir; Ahmad, Mohamed F.; Abdelaal, Mohamed A.; Abdelaziz, Muntasir M.

    2005-01-01

    We report a case of a 30-year-old female who had been treated periodically with steroids for idiopathic thrombocytopenic purpura ICTP over the last 10 years. Recently, during the course of investigation, she was found to have incidental asymptomatic multiple pulmonary nodules on chest CT. Following a needle biopsy to exclude malignancy, 2 nodules were excised and were histologically confirmed as pulmonary hyalinizing granuloma PHG. The remaining 2 nodules regressed on increasing her dose of steroids. The case is discussed with emphasis on the histological and radiological differential diagnosis, in addition to including ITP among the spectrum of immunologic conditions associated with PHG. (author)

  12. Hypervascular hyperplastic nodules appearing in chronic alcoholic liver disease: benign intrahepatic nodules mimicking hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Park, Won Kyu; Chang, Jay Chun; Kim, Jae Woon

    2006-01-01

    Hypervascular hyperplastic nodules in those patients with chronic alcoholic liver disease and who are hepatitis B and C negative have recently been reported on. The purpose of this study was to correlate the radiologic and pathologic findings with the clinical significance of these hypervascular hyperplastic nodules in chronic alcoholic liver disease. The study included eight hypervascular nodules of seven patients with chronic alcoholic liver disease, and these patients abused alcohol for more than 20 years. Eight hypervascular nodules were seen on the arterial phase of dynamic CT scans, but the possibility of HCC was excluded pathologically (n=4) or clinically. The radiologic and pathologic findings, and the changes of these nodules on follow up CT scans were retrospectively analyzed. All nodules showed good enhancement on the arterial phase. The tissue equilibrium phase of the dynamic CT scans showed isodensity in seven patients and low density in one patient. Ultrasound scans revealed hypoechoic findings for three nodules, isoechoic findings for two nodules, hyperechoic findings for one nodules, and two nodules were not detected. Angiograms (n=6) showed late incremental tumor staining, and all the nodules were well seen on the sinusoidal phase. CT during hepatic angiography (n=4) showed well stained tumor. CT during arterial portography (n=4) showed no defect in three nodules and nodular defect in on nodule. The MR images (n=3) showed low signal intensity in two nodules and iso-signal intensity in one nodule on T2WI. Five of six cases for which follow up CT scans were performed showed decrease in size and one was disappeared. Radiologically, it is often difficult to differentiate the hypervascular hyperplastic nodules seen in the chronic alcoholic liver disease from hepatocellular carcinoma, and histological confirmation is needed for excluded hepatocellular carcinoma. However, late tumor staining during the sinusoidal phase without any blood supply by feeding

  13. Hypervascular hyperplastic nodules appearing in chronic alcoholic liver disease: benign intrahepatic nodules mimicking hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Park, Won Kyu; Chang, Jay Chun; Kim, Jae Woon [College of Medicine, Yeungnam University, Daegu (Korea, Republic of)] (and others)

    2006-02-15

    Hypervascular hyperplastic nodules in those patients with chronic alcoholic liver disease and who are hepatitis B and C negative have recently been reported on. The purpose of this study was to correlate the radiologic and pathologic findings with the clinical significance of these hypervascular hyperplastic nodules in chronic alcoholic liver disease. The study included eight hypervascular nodules of seven patients with chronic alcoholic liver disease, and these patients abused alcohol for more than 20 years. Eight hypervascular nodules were seen on the arterial phase of dynamic CT scans, but the possibility of HCC was excluded pathologically (n=4) or clinically. The radiologic and pathologic findings, and the changes of these nodules on follow up CT scans were retrospectively analyzed. All nodules showed good enhancement on the arterial phase. The tissue equilibrium phase of the dynamic CT scans showed isodensity in seven patients and low density in one patient. Ultrasound scans revealed hypoechoic findings for three nodules, isoechoic findings for two nodules, hyperechoic findings for one nodules, and two nodules were not detected. Angiograms (n=6) showed late incremental tumor staining, and all the nodules were well seen on the sinusoidal phase. CT during hepatic angiography (n=4) showed well stained tumor. CT during arterial portography (n=4) showed no defect in three nodules and nodular defect in on nodule. The MR images (n=3) showed low signal intensity in two nodules and iso-signal intensity in one nodule on T2WI. Five of six cases for which follow up CT scans were performed showed decrease in size and one was disappeared. Radiologically, it is often difficult to differentiate the hypervascular hyperplastic nodules seen in the chronic alcoholic liver disease from hepatocellular carcinoma, and histological confirmation is needed for excluded hepatocellular carcinoma. However, late tumor staining during the sinusoidal phase without any blood supply by feeding

  14. Treatment of benign cold thyroid nodule: efficacy and safety of US-guided percutaneous ethanol injection

    International Nuclear Information System (INIS)

    Kim, Jeong Kon; Lee, Ho Kyu; Lee, Myung Joon; Choi, Choong Gon; Suh, Dae Chul; Ahn, Il Min

    1998-01-01

    The purpose of this study was to evaluate the efficacy and safety of US-guided percutaneous ethanol injection for the treatent of benign cold thyroid nodules. Twenty-five patients with benign cold thyroid nodules (volume of each at least 2ml proven by PCNA to be adenomatous hyperplasia, and cold nodule by thyroid scan) underwent a total of one to three percutaneous ethanol injections (PEI) at intervals of one or two months. The mean amount of ethanol used was 6.2(range, 1.5-8)ml, depending on the volume of the nodule. Follow up ultrasonography was performed one to four months after the final session. The initial volume of nodules was 11.4±4.1(range, 2.5-41.4)ml, and in all cases this fell by 56.1±22.3%(range, 10.9-92.1%);in all cases, follow-up ultrasonography showed that echogeneity was lower and its pattern was heterogeneous. There were no important longstanding complications;the most common side effect was acute pain at the injection site(n=3D9), and in one case, transient vocal cord palsy occurred. Our results show that US-guided percutaneous injection of ethanol is an effective and a safe procedure for the treatment of benign cold thyroid nodules, and is thus an alternative to surgery or hormone therapy.=20

  15. Beneficial effect of combined aspiration and interstitial laser therapy in patients with benign cystic thyroid nodules

    DEFF Research Database (Denmark)

    Døssing, H; Bennedbaek, F N; Hegedüs, L

    2006-01-01

    nodule causing local discomfort were assigned to cyst aspiration followed by ultrasound-guided ILP and followed for 12 months. The ILP was performed under continuous ultrasound-guidance and with an output power of 2.5-3.5 W. The volume of the nodules was assessed by means of ultrasound and determination...... part. Both pressure symptoms and cosmetic complaints were significantly reduced. The only side effect was mild pain or tenderness for a few days. Our study suggests that complete cyst aspiration and subsequent ultrasound-guided ILP of benign cystic thyroid nodules is a feasible and safe technique...

  16. Innovative techniques for image-guided ablation of benign thyroid nodules: Combined ethanol and radiofrequency ablation

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hye Sun; Baek, Jung Hwan; Choi, Young Jun; Lee, Jeong Hyun [Dept. of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2017-06-15

    In the treatment of benign thyroid nodules, ethanol ablation (EA), and radiofrequency ablation (RFA) have been suggested for cystic and solid thyroid nodules, respectively. Although combining these ablation techniques may be effective, no guidelines for or reviews of the combination have been published. Currently, there are three ways of combining EA and RFA: additional RFA is effective for treatment of incompletely resolved symptoms and solid residual portions of a thyroid nodule after EA. Additional EA can be performed for the residual unablated solid portion of a nodule after RFA if it is adjacent to critical structures (e.g., trachea, esophagus, and recurrent laryngeal nerve). In the concomitant procedure, ethanol is injected to control venous oozing after aspiration of cystic fluid prior to RFA of the remaining solid nodule.

  17. Comparison of quantitatively analyzed dynamic area-detector CT using various mathematic methods with FDG PET/CT in management of solitary pulmonary nodules.

    Science.gov (United States)

    Ohno, Yoshiharu; Nishio, Mizuho; Koyama, Hisanobu; Fujisawa, Yasuko; Yoshikawa, Takeshi; Matsumoto, Sumiaki; Sugimura, Kazuro

    2013-06-01

    The objective of our study was to prospectively compare the capability of dynamic area-detector CT analyzed with different mathematic methods and PET/CT in the management of pulmonary nodules. Fifty-two consecutive patients with 96 pulmonary nodules underwent dynamic area-detector CT, PET/CT, and microbacterial or pathologic examinations. All nodules were classified into the following groups: malignant nodules (n = 57), benign nodules with low biologic activity (n = 15), and benign nodules with high biologic activity (n = 24). On dynamic area-detector CT, the total, pulmonary arterial, and systemic arterial perfusions were calculated using the dual-input maximum slope method; perfusion was calculated using the single-input maximum slope method; and extraction fraction and blood volume (BV) were calculated using the Patlak plot method. All indexes were statistically compared among the three nodule groups. Then, receiver operating characteristic analyses were used to compare the diagnostic capabilities of the maximum standardized uptake value (SUVmax) and each perfusion parameter having a significant difference between malignant and benign nodules. Finally, the diagnostic performances of the indexes were compared by means of the McNemar test. No adverse effects were observed in this study. All indexes except extraction fraction and BV, both of which were calculated using the Patlak plot method, showed significant differences among the three groups (p method, pulmonary arterial perfusion calculated using the dual-input method, and perfusion calculated using the single-input method were significantly larger than that of SUVmax (p method (69.8%, p method has better potential for the diagnosis of pulmonary nodules than dynamic area-detector CT analyzed using other methods and than PET/CT.

  18. Therapy: a new nonsurgical therapy option for benign thyroid nodules?

    DEFF Research Database (Denmark)

    Hegedüs, Laszlo

    2009-01-01

    Despite the increasing implementation of iodization programs, benign nodular thyroid disease will remain a prevalent therapeutic concern for decades. recent research suggests that nonsurgical therapy, including radioactive iodine, radiofrequency thermal ablation and percutaneous laser ablation, m...

  19. Treatment of Benign Thyroid Nodules: Comparison of Surgery with Radiofrequency Ablation.

    Science.gov (United States)

    Che, Y; Jin, S; Shi, C; Wang, L; Zhang, X; Li, Y; Baek, J H

    2015-07-01

    Nodular goiter is one of the most common benign lesions in thyroid nodule. The main treatment of the disease is still the traditional surgical resection, however there are many problems such as general anesthesia, surgical scar, postoperative thyroid or parathyroid function abnormalities, and high nodules recurrence rate in residual gland. The purpose of this study was to compare the efficacy, safety, and cost-effectiveness of 2 treatment methods, surgery and radiofrequency ablation, for the treatment of benign thyroid nodules. From May 2012 to September 2013, 200 patients with nodular goiters who underwent surgery (group A) and 200 patients treated by radiofrequency ablation (group B) were enrolled in this study. Inclusion criteria were the following: 1) cosmetic problem, 2) nodule-related symptoms, 3) hyperfunctioning nodules related to thyrotoxicosis, and 4) refusal of surgery (for group B). An internally cooled radiofrequency ablation system and an 18-ga internally cooled electrode were used. We compared the 2 groups in terms of efficacy, safety, and cost-effectiveness during a 1-year follow-up. After radiofrequency ablation, the nodule volume decreased significantly from 5.4 to 0.4 mL (P = .002) at the 12-month follow-up. The incidence of complications was significantly higher from surgery than from radiofrequency ablation (6.0% versus 1.0%, P = .002). Hypothyroidism was detected in 71.5% of patients after surgery but in none following radiofrequency ablation. The rate of residual nodules (11.9% versus 2.9%, P = .004) and hospitalization days was significantly greater after surgery (6.6 versus 2.1 days, P radiofrequency ablation are both effective treatments of nodular goiter. Compared with surgery, the advantages of radiofrequency ablation include fewer complications, preservation of thyroid function, and fewer hospitalization days. Therefore, radiofrequency ablation should be considered a first-line treatment for benign thyroid nodules. © 2015 by American

  20. Efficacy of 99mTc-EDDA/HYNIC-TOC scintigraphy in differential diagnosis of solitary pulmonary nodules.

    Science.gov (United States)

    Płachcińska, Anna; Mikołajczak, Renata; Maecke, Helmut; Kozak, Józef; Michalski, Andrzej; Rzeszutek, Katarzyna; Kuśmierek, Jacek

    2004-10-01

    Fifty consecutive patients with solitary pulmonary nodules (SPN) on chest radiographs were studied scintigraphically after the administration of a somatostatin analog 99mTc-EDDA/HYNIC-TOC. The activity amounted to 740-925 MBq and a single photon emission computed tomography (SPECT) technique was applied. Verification of the nodule etiology was based on histology or cytology and bacteriology. As additional criterion for nodule benignity, its stable size in a chest radiograph for at least 3 years was accepted. In 31 patients, malignant etiologies of nodules were found. The diagnoses included: 11 adenocarcinomas, 6 squamous-cell carcinomas, 2 large-cell carcinomas, 6 nonsmall-cell lung cancers (NSCLC) of unspecified, more detailed morphology, 2 small-cell lung cancers (SCLC), 2 typical carcinoids, and 2 metastatic tumors: leiomyosarcoma and malignant melanoma. In 19 patients, the following benign tumors were diagnosed: 6 tuberculomas, 2 other granulomas, 4 hamartomas, 2 nonspecific inflammatory infiltrates, 1 abscess, 1 peripheral carcinoid of morphological characteristics of a benign tumor, 1 ectopic lesion of thyroid tissue, and 2 benign tumors of unspecified etiology, with stable size over 3 and 5 years. Positive scintigraphic results were obtained in 28 of 31 patients (90%) with malignant SPNs; among these there were 26 of 27 (96%) cases of primary pulmonary carcinoma. The remaining 2 false-negative cases included metastatic tumors: liposarcoma and melanoma. Among 19 benign lesions, 15 (79%) did not accumulate the radiopharmaceutical. The remaining 4 tumors visible on scintigrams included: 1 tuberculoma, 1 hamartoma, 1 abscess, and 1 case of nonestablished diagnosis (with stable size over 3 years). In conclusion, scintigraphy with 99mTc-EDDA/HYNIC-TOC appears to be an effective procedure for differentiation between malignant and benign SPNs.

  1. Quantitative Evaluation for Differentiating Malignant and Benign Thyroid Nodules Using Histogram Analysis of Grayscale Sonograms.

    Science.gov (United States)

    Nam, Se Jin; Yoo, Jaeheung; Lee, Hye Sun; Kim, Eun-Kyung; Moon, Hee Jung; Yoon, Jung Hyun; Kwak, Jin Young

    2016-04-01

    To evaluate the diagnostic value of histogram analysis using grayscale sonograms for differentiation of malignant and benign thyroid nodules. From July 2013 through October 2013, 579 nodules in 563 patients who had undergone ultrasound-guided fine-needle aspiration were included. For the grayscale histogram analysis, pixel echogenicity values in regions of interest were measured as 0 to 255 (0, black; 255, white) with in-house software. Five parameters (mean, skewness, kurtosis, standard deviation, and entropy) were obtained for each thyroid nodule. With principal component analysis, an index was derived. Diagnostic performance rates for the 5 histogram parameters and the principal component analysis index were calculated. A total of 563 patients were included in the study (mean age ± SD, 50.3 ± 12.3 years;range, 15-79 years). Of the 579 nodules, 431 were benign, and 148 were malignant. Among the 5 parameters and the principal component analysis index, the standard deviation (75.546 ± 14.153 versus 62.761 ± 16.01; P histogram analysis was feasible for differentiating malignant and benign thyroid nodules but did not show better diagnostic performance than subjective analysis performed by radiologists. Further technical advances will be needed to objectify interpretations of thyroid grayscale sonograms. © 2016 by the American Institute of Ultrasound in Medicine.

  2. Pulmonary nodule size evaluation with chest tomosynthesis.

    Science.gov (United States)

    Johnsson, Åse A; Fagman, Erika; Vikgren, Jenny; Fisichella, Valeria A; Boijsen, Marianne; Flinck, Agneta; Kheddache, Susanne; Svalkvist, Angelica; Båth, Magnus

    2012-10-01

    To evaluate intra- and interobserver variability, as well as agreement for nodule size measurements on chest tomosynthesis and computed tomographic (CT) images. The Regional Ethical Review Board approved this study, and all participants gave written informed consent. Thirty-six segmented nodules in 20 patients were included in the study. Eight observers measured the left-to-right, inferior-to-superior, and longest nodule diameters on chest tomosynthesis and CT images. Intra- and interobserver repeatability, as well as agreement between measurements on chest tomosynthesis and CT images, were assessed as recommended by Bland and Altman. The difference between the mean manual and the segmented diameter was -2.2 and -2.3 mm for left-to-right and -2.6 and -2.2 mm for the inferior-to-superior diameter for measurements on chest tomosynthesis and CT images, respectively. Intraobserver 95% limits of agreement (LOA) for the longest diameter ranged from a lower limit of -1.1 mm and an upper limit of 1.0 mm to -1.8 and 1.8 mm for chest tomosynthesis and from -0.6 and 0.9 mm to -3.1 and 2.2 mm for axial CT. Interobserver 95% LOA ranged from -1.3 and 1.5 mm to -2.0 and 2.1 mm for chest tomosynthesis and from -1.8 and 1.1 mm to -2.2 and 3.1 mm for axial CT. The 95% LOA concerning the mean of the observers' measurements of the longest diameter at chest tomosynthesis and axial CT were ±2.1 mm (mean measurement error, 0 mm). For the different observers, the 95% LOA between the modalities ranged from -2.2 and 1.6 mm to -3.2 and 2.8 mm. Measurements on chest tomosynthesis and CT images are comparable, because there is no evident bias between the modalities and the repeatability is similar. The LOA between measurements for the two modalities raise concern if measurements from chest tomosynthesis and CT were to be used interchangeably. © RSNA, 2012.

  3. Benign mural nodules within fluid collections at MRI after soft-tissue sarcoma resection.

    Science.gov (United States)

    Lantos, Joshua E; Hwang, Sinchun; Panicek, David M

    2014-06-01

    The purpose of this study was to determine the prevalence and clinical significance of nodules within fluid collections on MRI after surgical resection of soft-tissue sarcoma. This retrospective study included 175 patients who underwent resection of primary soft-tissue sarcoma and whose postoperative MRI reports mentioned fluid. Images were reviewed to determine the presence of fluid collections of 1 cm or greater in diameter in the surgical bed and any nodule (measuring ≥ 0.7 cm) within the collection. Signal intensity and characteristics of each collection and rim and presence of septa or blood products were recorded. Size, signal intensity, and contrast enhancement of nodules were reviewed. Nodules were classified as benign or malignant on the basis of histologic results or clinical or MRI follow-up. Fluid collections were present in 75 patients. Of those, 45 collections (60%) showed homogeneous fluid signal intensity and 30 (40%) were heterogeneous; septa were present in 45 (60%) and blood products in 12 (16%). Most collections showed a thin rim (59%) and rim enhancement (88%). Nodules were present along the inner wall of six (8%) collections. Four (66%) nodules enhanced and two (33%) were T1 hyperintense. At follow-up MRI, two nodules were stable in size, one decreased, and three resolved. Nodules in three patients were biopsied; all were benign. Two other patients had no recurrence at follow-up, and another died at 3 months. A nodule within a postoperative fluid collection at MRI after soft-tissue sarcoma resection generally does not represent tumor recurrence; short-interval follow-up MRI is recommended rather than immediate biopsy.

  4. Granulomatous Bronchiolitis with Necrobiotic Pulmonary Nodules in Chrohn's Disease

    Directory of Open Access Journals (Sweden)

    Hugh J Freeman

    2004-01-01

    Full Text Available A 37-year-old man with extensive Crohn's disease of the stomach, small and large intestine for almost a decade developed respiratory symptoms and radiological findings suggestive of pneumonia that failed to resolve with antibiotic treatment. Computed tomography scanning of his lungs showed extensive changes with cavitated parenchymal nodules. Histological evaluation of an open lung biopsy showed granulomatous bronchiolitis and pulmonary necrobiosis. Treatment with steroids and immunosuppression resulted in complete resolution of his clinical symptoms of pneumonia and abnormal computed tomography imaging changes. Granulomatous bronchiolitis and necrobiotic nodules may be a manifestation of Crohn's disease in the absence of microbial agents, including mycobacteria or fungal agents. While a multiplicity of complex pulmonary changes may occur in Crohn's disease, their clinical recognition and precise pathological definition may be particularly important if treatment with a biological agent, such as infliximab, is being considered.

  5. Association of Pro-apoptotic Bad Gene Expression Changes with Benign Thyroid Nodules.

    Science.gov (United States)

    Gül, Nurdan; Temel, Berna; Ustek, Duran; Sirma-Ekmekçi, Sema; Kapran, Yersu; Tunca, Fatih; Giles-Şenyürek, Yasemin; Özbek, Uğur; Alagöl, Faruk

    2018-01-01

    This study aimed to investigate the role of the mitochondrial apoptotic pathway in benign thyroid nodules. Paired samples of nodular and normal tissues were collected from 26 patients with nodular goiters undergoing thyroidectomy. Variable expression of Bcl-2, Bax and Bad genes were evaluated by quantitative PCR. Expression level of Bad gene in nodules was found to be significantly decreased compared to normal tissues (p=0.049). A positive correlation was observed between nodule size and Bad expression levels (correlation coefficient=0.563, p=0.004); and this correlation was stronger in hot nodules (n=18, correlation coefficient=0.689, p=0.003). No significant difference was observed between nodular and normal tissue expressions of Bax and Bcl-2. These results suggest that Bad expression correlates with the size of benign thyroid nodules and also its relatively lower expression in nodules, warrant further investigation. Copyright© 2018, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  6. A Rare Cause of Pulmonary Nodules

    Directory of Open Access Journals (Sweden)

    Michael Tsuyoshi Chew

    2016-10-01

    Full Text Available Crohn’s disease is a chronic, idiopathic autoimmune disorder that primarily targets the gastrointestinal (GI system. It is characterized by transmural inflammation of the GI tract that can occur anywhere from the mouth to the anus. Not infrequently, the disease may also have extraintestinal manifestations (EIMs that can affect almost any organ system. It is estimated that EIMs affect up to 36% of patients with Crohn’s disease, but the incidence and prevalence of pulmonary involvement are variable in the literature and may be as low as 0.4%. There are few case reports documenting pulmonary manifestations, as they are often overlooked, especially if respiratory symptoms are present before the diagnosis of GI manifestations, as in the present case. A 44-year-old otherwise healthy woman presented with nonspecific respiratory complaints, recurrent pneumonias, and multiple computed tomography images showing diffuse, migratory, nodular, and consolidative parenchymal lung disease, with a largely unremarkable infectious and rheumatologic evaluation. Lung biopsy revealed necrotizing and nonnecrotizing granulomas, raising concern for sarcoidosis. Subsequent imaging revealed an incidental mass in the cecum. Biopsy of the cecum lesion revealed acute cryptitis, crypt abscess, and a single poorly formed granuloma, suggesting the possibility of Crohn’s disease. In this report, we present a patient whose pulmonary manifestations ultimately led to the diagnosis of Crohn’s disease.

  7. SU-F-R-22: Malignancy Classification for Small Pulmonary Nodules with Radiomics and Logistic Regression

    Energy Technology Data Exchange (ETDEWEB)

    Huang, W; Tu, S [Chang Gung University, Kwei-shan, Tao-Yuan, Taiwan (China)

    2016-06-15

    Purpose: We conducted a retrospective study of Radiomics research for classifying malignancy of small pulmonary nodules. A machine learning algorithm of logistic regression and open research platform of Radiomics, IBEX (Imaging Biomarker Explorer), were used to evaluate the classification accuracy. Methods: The training set included 100 CT image series from cancer patients with small pulmonary nodules where the average diameter is 1.10 cm. These patients registered at Chang Gung Memorial Hospital and received a CT-guided operation of lung cancer lobectomy. The specimens were classified by experienced pathologists with a B (benign) or M (malignant). CT images with slice thickness of 0.625 mm were acquired from a GE BrightSpeed 16 scanner. The study was formally approved by our institutional internal review board. Nodules were delineated and 374 feature parameters were extracted from IBEX. We first used the t-test and p-value criteria to study which feature can differentiate between group B and M. Then we implemented a logistic regression algorithm to perform nodule malignancy classification. 10-fold cross-validation and the receiver operating characteristic curve (ROC) were used to evaluate the classification accuracy. Finally hierarchical clustering analysis, Spearman rank correlation coefficient, and clustering heat map were used to further study correlation characteristics among different features. Results: 238 features were found differentiable between group B and M based on whether their statistical p-values were less than 0.05. A forward search algorithm was used to select an optimal combination of features for the best classification and 9 features were identified. Our study found the best accuracy of classifying malignancy was 0.79±0.01 with the 10-fold cross-validation. The area under the ROC curve was 0.81±0.02. Conclusion: Benign nodules may be treated as a malignant tumor in low-dose CT and patients may undergo unnecessary surgeries or treatments. Our

  8. Hashimoto thyroiditis: Part 2, sonographic analysis of benign and malignant nodules in patients with diffuse Hashimoto thyroiditis.

    Science.gov (United States)

    Anderson, Lauren; Middleton, William D; Teefey, Sharlene A; Reading, Carl C; Langer, Jill E; Desser, Terry; Szabunio, Margaret M; Mandel, Susan J; Hildebolt, Charles F; Cronan, John J

    2010-07-01

    The purpose of this article is to compare sonographic features of benign and malignant nodules in patients with diffuse Hashimoto thyroiditis. As part of an ongoing multiinstitutional study, patients who underwent ultrasound and fine-needle aspiration of one or more thyroid nodules were analyzed for a variety of predetermined sonographic features. Patients with a sonographic appearance consistent with diffuse Hashimoto thyroiditis and with coexisting nodules that could be confirmed to be benign or malignant by fine-needle aspiration or surgical pathologic analysis were included in the study. Among nodules within diffuse Hashimoto thyroiditis, 84% (69/82) were benign (35 nodular Hashimoto thyroiditis, 32 nodular hyperplasia, and two follicular adenoma), and 16% (13/82) were malignant (12 papillary carcinoma and one lymphoma). Malignant nodules were more likely to be solid and hypoechoic (62% vs 19%). All types of calcifications were more prevalent among malignant nodules, including microcalcifications (39% vs 0%), nonspecific tiny bright reflectors (39% vs 6%), macrocalcifications (15% vs 3%), and eggshell (15% vs 2%). Benign nodules were more likely to be hyperechoic (46% vs 9%), to have a halo (39% vs 15%), and to lack calcifications (88% vs 23%). Benign nodules more often had ill-defined margins (36% vs 8%). Sonographic features of benign and malignant nodules within diffuse Hashimoto thyroiditis are generally similar to the features typical of benign and malignant nodules in the general population. If calcifications of any type are added to the list of malignant sonographic features, the decision to biopsy a nodule in patients with diffuse Hashimoto thyroiditis can be based on recommendations that have been published previously.

  9. Diagnostic value of coincidence detection emission tomography using fluorine 18 2-fluoro-2-deoxy-D-glucose in patients with solitary pulmonary nodules

    International Nuclear Information System (INIS)

    Najjar, F.

    2008-12-01

    Solitary Pulmonary Nodules (size 18 FDG). The aim of this project was to establish the diagnostic role of this imaging modality with and without attenuation correction (AC) in correlation with computed tomography (CT) findings in patients with solitary pulmonary nodules and its efficacy for the distinction between benign and malignant nodules. Sixty-eight patients were included in this study. All patients presented with suspected pulmonary nodules on thoracic CT. In addition, they had CDET scan using a dual-head coincidence gamma-camera with and without measured attenuation using caesium-137 source. Corrected images were independently interpreted from non-attenuation corrected images in a blinded manner of any clinical data. For data analysis, 18 FDG-CDET findings were evaluated by histology when or the final clinical outcome. Our results showed that the diagnostic accuracy of CDET has not been ameliorated when a lower thresholds of 18 FDG uptake was considered for the evaluation of nodule's malignancy in image interpretation. A total of 66 suspected nodules were observed by CT. In addition, 5 pulmonary nodules have been detected by CDET only. Malignant pulmonary disease was found in 38 of these nodules whereas 33 pulmonary nodules were proved to be benign. The sensitivity of 18 FDG-CDET imaging with and without AC was 91%, whereas its specificity has been decreased to 81% with AC and only 69% without AC. These results could be explained by additional false positive findings obtained with non AC mode in 8% of patients. All malignant nodules >20 mm in diameter have been identified by 18 FDG-CDET. However, both modalities techniques failed to detect malignancy in 3 patients. In . general, the diagnostic accuracy of 18 FDG-CDET without AC was relatively comparable to that found with AC (83% to 87%, respectively). Our results indicate that 18 FDG-CDET imaging with and without AC is a reliable method for the diagnosis of solitary pulmonary nodules and the distinction

  10. Computed Tomography Features of Benign and Malignant Calcified Thyroid Nodules: A Single-Center Study.

    Science.gov (United States)

    Kim, Donghyun; Kim, Dong Wook; Heo, Young Jin; Baek, Jin Wook; Lee, Yoo Jin; Park, Young Mi; Baek, Hye Jin; Jung, Soo Jin

    No previous studies have investigated thyroid calcification on computed tomography (CT) quantitatively by using Hounsfield unit (HU) values. This study aimed to analyze quantitative HU values of thyroid calcification on preoperative neck CT and to assess the characteristics of benign and malignant calcified thyroid nodules (CTNs). Two hundred twenty patients who underwent neck CT before thyroid surgery from January 2015 to June 2016 were included. On soft-tissue window CT images, CTNs with calcified components of 3 mm or larger in minimum diameter were included in this study. The HU values and types of CTNs were determined and analyzed. Of 61 CTNs in 49 patients, there were 42 malignant nodules and 19 benign nodules. The mean largest diameter of the calcified component was 5.3 (2.5) mm (range, 3.1-17.1 mm). A statistically significant difference was observed in the HU values of calcified portions between benign and malignant CTNs, whereas there was no significant difference in patient age or sex or in the size, location, or type of each CTN. Of the 8 CTNs with pure calcification, 3 exhibited a honeycomb pattern on bone window CT images, and these 3 CTNs were all diagnosed as papillary thyroid carcinoma on histopathological examination. Hounsfield unit values of CTNs may be helpful for differentiating malignancy from benignity.

  11. Acoustic radiation force impulse elastography for differentiation of benign and malignant thyroid nodules with concurrent Hashimoto's thyroiditis.

    Science.gov (United States)

    Liu, Bo-Ji; Xu, Hui-Xiong; Zhang, Yi-Feng; Xu, Jun-Mei; Li, Dan-Dan; Bo, Xiao-Wan; Li, Xiao-Long; Guo, Le-Hang; Xu, Xiao-Hong; Qu, Shen

    2015-03-01

    The purpose of the study was to explore the diagnostic performance of acoustic radiation force impulse (ARFI) elastography in differential diagnosis between benign and malignant thyroid nodules in patients with coexistent Hashimoto's thyroiditis (HT). A total of 141 pathological proven nodules in 141 HT patients (7 males and 134 females, mean age 50.1 years, range 23-75 years) received conventional ultrasound (US), elasticity imaging (EI) and ARFI elastography, including virtual touch tissue imaging (VTI) and virtual touch tissue quantification (VTQ), before surgery. Shear wave velocity (SWV) and SWV ratio were measured for each nodule on VTQ. The US, EI and ARFI elastography features were compared between benign and malignant nodules in HT patients. Receiver operating characteristic curve (ROC) analyses and area under curve (AUC) were performed to assess the diagnostic performance. Pathologically, 70 nodules were benign and 71 nodules were malignant. Significant differences were found between benign and malignant nodules in HT patients for EI (EI score) and ARFI (VTI grade and SWV) (all P value benign and malignant thyroid nodules in HT patients. The diagnostic performance of ARFI elastography is better than EI.

  12. Inference method using bayesian network for diagnosis of pulmonary nodules

    International Nuclear Information System (INIS)

    Kawagishi, Masami; Iizuka, Yoshio; Yamamoto, Hiroyuki; Yakami, Masahiro; Kubo, Takeshi; Fujimoto, Koji; Togashi, Kaori

    2010-01-01

    This report describes the improvements of a naive Bayes model that infers the diagnosis of pulmonary nodules in chest CT images based on the findings obtained when a radiologist interprets the CT images. We have previously introduced an inference model using a naive Bayes classifier and have reported its clinical value based on evaluation using clinical data. In the present report, we introduce the following improvements to the original inference model: the selection of findings based on correlations and the generation of a model using only these findings, and the introduction of classifiers that integrate several simple classifiers each of which is specialized for specific diagnosis. These improvements were found to increase the inference accuracy by 10.4% (p<.01) as compared to the original model in 100 cases (222 nodules) based on leave-one-out evaluation. (author)

  13. Role of apparent diffusion coefficient values and diffusion weighted magnetic resonance imaging in differentiation between benign and malignant thyroid nodules

    International Nuclear Information System (INIS)

    Incedayi, M.; Sivrioglu, A.; Mutlu, H.; Sonmez, G.; Velioglu, M.; Sildiroglu, O.; Basekim, C.; Kizilkaya, E.

    2012-01-01

    Full text: Objective: The purpose of the study was to differentiate between benign and malignant thyroid nodules using nodule-spinal cord signal intensity and nodule apparent diffusion coefficient (ADC) ratios on diffusion weighted magnetic resonance imaging. Materials and methods: Forty-four patients (27 females, 17 males; mean age 49) with nodules who underwent diffusion weighted magnetic resonance imaging (DW-MRI) were included in this study. The images were acquired with 0, 50, 400 and 1000 s/mm 2 b values. ADC maps were calculated afterwards. Fine needle aspiration biopsies (FNAB) were performed at the same day with DW-MRI acquisition. The diagnosis in patients where malignity was detected after FNAB was confirmed by histopathologic analysis of the operation material. The signal intensities of the spinal cord and the nodule were measured additionally, over b-1000 diffusion weighted images. Nodule /cord signal intensity (SI) ratios were obtained and the digital values were calculated by dividing to ADC values estimated for each nodule. Statistical analysis was performed. Results: The (nodule SI-cord SI)/nodule ADC ratio is calculated in the DW images and a statistically significant relationship was found between this ratio and the histopathology of the nodules (p<0.001). The ratio was determined as 0.27 in benign, and 0.86 in malignant lesions. The result of ROC analysis was statistically significant, and the area under Receiver Operating Characteristic (ROC) curve (100%) was considerably high. The threshold value was calculated as 0.56 according to the ROC analysis. According to this threshold value, the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy rates for (nodule SI/cord SI)/ADC ratios in differentiating benign from malignant thyroid nodules are calculated as 100%, 97%, 83%, 100%, and 98%, respectively. Conclusion: We have found that (nodule/cord SI)/ nodule ADC ratio has the highest values for

  14. Computer-aided Detection Fidelity of Pulmonary Nodules in Chest Radiograph

    Directory of Open Access Journals (Sweden)

    Nikolaos Dellios

    2017-01-01

    Full Text Available Aim: The most ubiquitous chest diagnostic method is the chest radiograph. A common radiographic finding, quite often incidental, is the nodular pulmonary lesion. The detection of small lesions out of complex parenchymal structure is a daily clinical challenge. In this study, we investigate the efficacy of the computer-aided detection (CAD software package SoftView™ 2.4A for bone suppression and OnGuard™ 5.2 (Riverain Technologies, Miamisburg, OH, USA for automated detection of pulmonary nodules in chest radiographs. Subjects and Methods: We retrospectively evaluated a dataset of 100 posteroanterior chest radiographs with pulmonary nodular lesions ranging from 5 to 85 mm. All nodules were confirmed with a consecutive computed tomography scan and histologically classified as 75% malignant. The number of detected lesions by observation in unprocessed images was compared to the number and dignity of CAD-detected lesions in bone-suppressed images (BSIs. Results: SoftView™ BSI does not affect the objective lesion-to-background contrast. OnGuard™ has a stand-alone sensitivity of 62% and specificity of 58% for nodular lesion detection in chest radiographs. The false positive rate is 0.88/image and the false negative (FN rate is 0.35/image. From the true positive lesions, 20% were proven benign and 80% were malignant. FN lesions were 47% benign and 53% malignant. Conclusion: We conclude that CAD does not qualify for a stand-alone standard of diagnosis. The use of CAD accompanied with a critical radiological assessment of the software suggested pattern appears more realistic. Accordingly, it is essential to focus on studies assessing the quality-time-cost profile of real-time (as opposed to retrospective CAD implementation in clinical diagnostics.

  15. Short communication: Semiquantitative assessment of 99mTc-EDDA/HYNIC-TOC scintigraphy in differentiation of solitary pulmonary nodules--a complementary role to visual analysis.

    Science.gov (United States)

    Płachcińska, Anna; Mikołajczak, Renata; Kozak, Józef; Rzeszutek, Katarzyna; Kuśmierek, Jacek

    2006-02-01

    The aim of this study was the assessment of a value of a semiquantitative analysis of scintigrams obtained with (99m)Tc-EDDA/HYNIC-TOC as a radiopharmaceutical (RPH) in differential diagnosis of solitary pulmonary nodules (SPNs), as a method complementary to visual evaluation of scintigrams. Scintigraphic images of 59 patients (33 males and 26 females between 34 and 78 years of age, mean value, 57) with SPN on chest radiographs (39 malignant and 20 benign) were retrospectively assessed semiquantitatively. Visual scintigram analysis was made earlier, prospectively. Nodule diameters ranged from 1 to 4 (mean 2.2) cm. A single photon emission computed tomography (SPECT) acquisition was performed at 2-4 hours after administration of 740 to 925 MBq of a RPH. Verification of scintigraphic results was based on a pathological examination of tumor samples (histopathology or cytology) and, in some cases, on bacteriological studies. As an additional criterion for tumor benignity, its stable size in a time interval not shorter than 3 years was accepted. A simple, semiquantitative method for assessment of radiopharmaceutical uptake in SPNs was used, based on "count sample" taken from tumor center (T) in relation to radiopharmaceutical concentration in the background (B) measured in the contralateral lung. A criterion for optimal differentiation between malignant and benign nodules (T/B ratio threshold value) was introduced, based on a receiver operating characteristic (ROC) curve. Additionally, a value of T/B ratio was searched for, excluding tumor benignity with high probability. Visual analysis of scintigrams revealed enhanced uptake of RPH at 36 of 39 (92%) sites, corresponding to locations of malignant nodules (including 34 of 35-97% cases of lung cancer). In 13 of 20 (65%) benign nodules, true negative results were obtained. Accuracy of the method equalled 83%. Optimal differentiation between malignant and benign nodules was found for a value of a T/B ratio amounting to 2

  16. Local pulmonary structure classification for computer-aided nodule detection

    Science.gov (United States)

    Bahlmann, Claus; Li, Xianlin; Okada, Kazunori

    2006-03-01

    We propose a new method of classifying the local structure types, such as nodules, vessels, and junctions, in thoracic CT scans. This classification is important in the context of computer aided detection (CAD) of lung nodules. The proposed method can be used as a post-process component of any lung CAD system. In such a scenario, the classification results provide an effective means of removing false positives caused by vessels and junctions thus improving overall performance. As main advantage, the proposed solution transforms the complex problem of classifying various 3D topological structures into much simpler 2D data clustering problem, to which more generic and flexible solutions are available in literature, and which is better suited for visualization. Given a nodule candidate, first, our solution robustly fits an anisotropic Gaussian to the data. The resulting Gaussian center and spread parameters are used to affine-normalize the data domain so as to warp the fitted anisotropic ellipsoid into a fixed-size isotropic sphere. We propose an automatic method to extract a 3D spherical manifold, containing the appropriate bounding surface of the target structure. Scale selection is performed by a data driven entropy minimization approach. The manifold is analyzed for high intensity clusters, corresponding to protruding structures. Techniques involve EMclustering with automatic mode number estimation, directional statistics, and hierarchical clustering with a modified Bhattacharyya distance. The estimated number of high intensity clusters explicitly determines the type of pulmonary structures: nodule (0), attached nodule (1), vessel (2), junction (>3). We show accurate classification results for selected examples in thoracic CT scans. This local procedure is more flexible and efficient than current state of the art and will help to improve the accuracy of general lung CAD systems.

  17. Rheumatoid arthritis and pulmonary nodules: An unexpected final diagnosis.

    Science.gov (United States)

    Zurita Prada, Pablo Antonio; Urrego Laurín, Claudia Lía; Assyaaton Bobo, Sow; Faré García, Regina; Estrada Trigueros, Graciliano; Gallardo Romero, José Manuel; Borrego Pintado, Maria Henar

    We report the case of a 50-year-old female smoker with an 11-year history of seropositive rheumatoid arthritis (rheumatoid factor and anti-cyclic citrullinated peptide antibodies) receiving triple therapy. She developed pulmonary nodules diagnosed as Langerhans cell histiocytosis by lung biopsy. We found no reported cases of the coexistence of these two diseases. Smoking abstinence led to radiologic resolution without modifying the immunosuppressive therapy. Copyright © 2016 Elsevier España, S.L.U. and Sociedad Española de Reumatología y Colegio Mexicano de Reumatología. All rights reserved.

  18. Bag of frequencies: a descriptor of pulmonary nodules in Computed Tomography images

    NARCIS (Netherlands)

    Ciompi, F.; Jacobs, C.; Scholten, E.T.; Wille, M.M.W.; Jong, P.A. de; Prokop, M.; Ginneken, B. van

    2015-01-01

    We present a novel descriptor for the characterization of pulmonary nodules in computed tomography (CT) images. The descriptor encodes information on nodule morphology and has scale-invariant and rotation-invariant properties. Information on nodule morphology is captured by sampling intensity

  19. Effect of ultrasound-guided interstitial laser photocoagulation on benign solitary solid cold thyroid nodules

    DEFF Research Database (Denmark)

    Døssing, Helle; Bennedbaek, Finn Noe; Hegedüs, Laszlo

    2006-01-01

    with a cytologically benign solitary solid and scintigraphically cold thyroid nodule causing local discomfort were assigned to one session of ILP (ILP-1) (n = 15) or three monthly ILP sessions (ILP-3) (n = 15) and followed for 6 months. ILP was performed under continuous ultrasound (US)--guidance and with an output...... power of 2.5-3.5 W. Thyroid nodule volume was assessed by US. Pressure and cosmetic complaints were evaluated on a visual analogue scale. MAIN OUTCOME: In the ILP- 1 group, thyroid nodule volume decreased from 10.1 +/- 4.3 mL (mean +/- standard deviation [SD]) to 5.7 +/- 3.2 mL (p = 0...

  20. Usefulness of virtual images of the visceral pleura in identifying the localization of peripheral small pulmonary nodules intraoperatively

    International Nuclear Information System (INIS)

    Kambayashi, Takatoyo

    2011-01-01

    The objective of this study was to assess the usefulness of virtual images of the visceral pleura in identifying the localization of peripheral small pulmonary nodules intraoperatively. We examined 12 cases with 12 peripheral small pulmonary nodules between 2008 and 2010. All lesions were predicted to be difficult to identify during surgery, and virtual images of the visceral pleura were made and evaluated before surgery. We predicted the usefulness of virtual images of the visceral pleura in identifying the localization of peripheral small pulmonary nodules. The mean maximum dimensions were 10.5±4.36 mm. The mean depth from the visceral pleura was 4.0±4.67 mm. The lesions were the solid type in 6 cases and the ground-glass opacity type in 6 cases. In 7 cases primary lung cancer was present, while the other 5 cases had only benign lesions. In all cases, changes in the visceral pleura could be identified with virtual images of the visceral pleura before surgery. We identified 7 lesions out of 12 intraoperatively. The reasons for the failure to identify the lesions were an inability to adequately observe the visceral pleura because of pleural adhesion, or failure to perform single lung ventilation in 3 cases. Another reason was that the changes in the visceral pleura were too minor to identify intraoperatively (2 cases). Virtual images of the visceral pleura may be useful for identifying the localization of peripheral small pulmonary nodules, and the prediction of whether or not the identification of lesions is possible intraoperatively, without preoperative marking in order to identify peripheral pulmonary nodules. (author)

  1. Whether and under what conditions FDG-PET might be cost-effective in evaluating solitary pulmonary nodules depicted on lung cancer screening in Japan

    International Nuclear Information System (INIS)

    Tsushima, Yoshito; Aoki, Jun; Endo, Keigo

    2003-01-01

    The purpose of this study was to determine whether and under what conditions fluorine-18 fluorodeoxyglucose positron emission tomography (FDG-PET) may be cost-effective in evaluating solitary pulmonary nodules depicted on lung cancer screening in Japan. Three decision models for differentiating lung cancer from benign nodules were compared: CT alone, PET alone, and CT plus PET. The various paths of each strategy were dependent on variables determined from a review of the medical literature. Costs were based on Japanese health insurance. The prevalence of lung cancer among solitary pulmonary nodules detected on lung cancer screening was less than 10%. For this prevalence, the CT-plus-PET model was the cost-effective alternative to the CT-alone model (cost savings were 64,000 yen per patient) and provided greater accuracy (0.90 vs. 0.84). Both of these effects were the result of reducing the number of candidates who undergo unnecessary CT-guided or bronchofiberscopic biopsies or thoracotomy for a benign pulmonary nodule. The CT-plus-PET strategy is accurate and cost-effective for the characterization of solitary pulmonary nodules detected on lung cancer screening in Japan. (author)

  2. Application of texture analysis method for classification of benign and malignant thyroid nodules in ultrasound images.

    Science.gov (United States)

    Abbasian Ardakani, Ali; Gharbali, Akbar; Mohammadi, Afshin

    2015-01-01

    The aim of this study was to evaluate computer aided diagnosis (CAD) system with texture analysis (TA) to improve radiologists' accuracy in identification of thyroid nodules as malignant or benign. A total of 70 cases (26 benign and 44 malignant) were analyzed in this study. We extracted up to 270 statistical texture features as a descriptor for each selected region of interests (ROIs) in three normalization schemes (default, 3s and 1%-99%). Then features by the lowest probability of classification error and average correlation coefficients (POE+ACC), and Fisher coefficient (Fisher) eliminated to 10 best and most effective features. These features were analyzed under standard and nonstandard states. For TA of the thyroid nodules, Principle Component Analysis (PCA), Linear Discriminant Analysis (LDA) and Non-Linear Discriminant Analysis (NDA) were applied. First Nearest-Neighbour (1-NN) classifier was performed for the features resulting from PCA and LDA. NDA features were classified by artificial neural network (A-NN). Receiver operating characteristic (ROC) curve analysis was used for examining the performance of TA methods. The best results were driven in 1-99% normalization with features extracted by POE+ACC algorithm and analyzed by NDA with the area under the ROC curve ( Az) of 0.9722 which correspond to sensitivity of 94.45%, specificity of 100%, and accuracy of 97.14%. Our results indicate that TA is a reliable method, can provide useful information help radiologist in detection and classification of benign and malignant thyroid nodules.

  3. Advances in intelligent diagnosis methods for pulmonary ground-glass opacity nodules.

    Science.gov (United States)

    Yang, Jing; Wang, Hailin; Geng, Chen; Dai, Yakang; Ji, Jiansong

    2018-02-07

    Pulmonary nodule is one of the important lesions of lung cancer, mainly divided into two categories of solid nodules and ground glass nodules. The improvement of diagnosis of lung cancer has significant clinical significance, which could be realized by machine learning techniques. At present, there have been a lot of researches focusing on solid nodules. But the research on ground glass nodules started late, and lacked research results. This paper summarizes the research progress of the method of intelligent diagnosis for pulmonary nodules since 2014. It is described in details from four aspects: nodular signs, data analysis methods, prediction models and system evaluation. This paper aims to provide the research material for researchers of the clinical diagnosis and intelligent analysis of lung cancer, and further improve the precision of pulmonary ground glass nodule diagnosis.

  4. Evaluation of solitary pulmonary nodules by integrated PET/CT: improved accuracy by FDG uptake pattern and CT findings

    International Nuclear Information System (INIS)

    Joon Young Choi; Kyung Soo Lee; O Jung Kwon; Young Mog Shim; Kyung-Han Lee; Yong Choi; Yearn Seong Choe; Byung-Tae Kim

    2004-01-01

    Objective: FDG PET is useful to differentiate malignancy from benign lesions in the evaluation of solitary pulmonary nodules (SPNs). However, FDG PET showed false positive results in benign inflammatory lesions such as tuberculosis and organizing pneumonia. Furthermore, malignant tumors such as adenocarcinoma (AC) with bronchioloalveolar carcinoma (BAC) type had lower FDG uptake than other cell types of non-small cell lung cancer. We investigated whether FDG uptake pattern and image findings of CT for attenuation correction could improve accuracy for evaluating SPNs over SUV in integrated PET/CT imaging using FDG. Methods: Forty patients (M:F = 23:17, mean age 58.2±9.4 yrs) with non-calcified SPNs (diameter on CT 30 mm, no significant mediastinal node enlargement, no atelectasis) were included. All subjects underwent integrated PET/CT imaging using FDG. One nuclear medicine physician and 1 chest radiologist interpreted the PET and non-contrast CT images for attenuation correction, respectively. On PET images, maximum SUV of SPN was acquired, and FDG uptake pattern was categorized as diffusely increased or heterogeneously increased with upper threshold of window setting adjusted to maximum SUV of each nodule. A radiologist interpreted SPNs as benign or malignant based on CT images with lung and mediastinai window settings blinded to PET findings. Results: On pathological exam, 30 SPNs were confirmed to be malignant (11 AC with non-BAC type, 8 AC with BAC type, 8 squamous cell carcinoma, 1 adenosquamous cell carcinoma, 1 neuroendocrine carcinoma, 1 large cell carcinoma), and 10 were benign (4 tuberculosis, 3 organizing pneumonia, 2 sclerosing pneumocytoma, 1 non-specific inflammation). All 5 nodules with max SUV 7.0 except one with tuberculoma had malignancy. When only nodules with diffusely increased uptake were considered malignant in indeterminate group with max SUV of 4.0 to 7.0, PET could diagnose 5 of 9 malignant nodules with one false positive nodule. In 6 of

  5. Surgical Treatment of Small Pulmonary Nodules Under Video-assisted Thoracoscopy 
(A Report of 129 Cases

    Directory of Open Access Journals (Sweden)

    Tong WANG

    2017-01-01

    Full Text Available Background and objective The development of image technology has led to increasing detection of pulmonary small nodules year by year, but the determination of their nature before operation is difficult. This clinical study aimed to investigate the necessity and feasibility of surgical resection of pulmonary small nodules through a minimally invasive approach and the operational manner of non-small cell lung cancer (NSCLC. Methods The clinical data of 129 cases with pulmonary small nodule of 10 mm or less in diameter were retrospectively analyzed in our hospital from December 2013 to November 2016. Thin-section computed tomography (CT was performed on all cases with 129 pulmonary small nodules. CT-guided hook-wire precise localization was performed on 21 cases. Lobectomy, wedge resection, and segmentectomy with lymph node dissection might be performed in patients according to physical condition. Results Results of the pathological examination of 37 solid pulmonary nodules (SPNs revealed 3 primary squamous cell lung cancers, 3 invasive adenocarcinomas (IAs, 2 metastatic cancers, 2 small cell lung cancers (SCLCs, 16 hamartomas, and 12 nonspecific chronic inflammations. The results of pathological examination of 49 mixed ground glass opacities revealed 19 IAs, 6 micro invasive adenocarcinomas (MIAs, 4 adenocarcinomas in situ (AIS, 1 atypical adenomatous hyperplasia (AAH, 1 SCLC, and 18 nonspecific chronic inflammations. The results of pathological examination of 43 pure ground glass opacities revealed 19 AIS, 6 MIAs, 6 IA, 6 AAHs, and 6 nonspecific chronic inflammations. Wedge resection under video-assisted thoracoscopic surgery (VATS was performed in patients with 52 benign pulmonary small nodules. Lobectomy and systematic lymph node dissection under VATS were performed in 33 patients with NSCLC. Segmentectomy with selective lymph node dissection, wedge resection, and selective lymph node dissection under VATS were performed in six patients with

  6. Significance of pulmonary nodules in patients with colorectal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Pomerri, Fabio [Veneto Institute of Oncology IOV-IRCCS, Oncological Radiology Unit, Padua (Italy); University of Padua, Department of Medicine, Padua (Italy); Istituto Oncologico Veneto IOV-IRCCS, Radiologia, Padova (Italy); Pucciarelli, Salvatore; Nitti, Donato [University of Padua, Department of Oncological and Surgical Sciences, 2nd Surgical Clinic, Padua (Italy); Maretto, Isacco [Veneto Institute of Oncology IOV-IRCCS, Surgical Unit, Padua (Italy); Perrone, Ernesta; Pintacuda, Giovanna [Veneto Institute of Oncology IOV-IRCCS, Oncological Radiology Unit, Padua (Italy); Lonardi, Sara [Veneto Institute of Oncology IOV-IRCCS, Medical Oncology Unit 1, Padua (Italy); Muzzio, Pier Carlo [Veneto Institute of Oncology IOV-IRCCS, Padua (Italy)

    2012-08-15

    Radiographically small pulmonary nodules (PNs) in patients with colorectal cancer are troublesome because their discovery raises concern about metastases. This study sought to establish the appropriate timing of radiological follow-up for PNs detected at initial staging evaluation of colorectal carcinoma patients. The medical records of 376 consecutive colorectal cancer patients who underwent curative surgery and had baseline and follow-up chest X-rays (CXR) and computed tomography (CT) were reviewed. The study included 92 patients who had all CXR and chest CT available for review, at least one PN found on baseline imaging, and no synchronous neoplasms. On baseline chest CT, these 92 patients had 170 PNs altogether and 77 (45.2 %) of them were greater than 5 mm in size. Baseline CXR detected 13 PNs in 12 patients and all but 2 were larger than 5 mm. Nodule size greater than 5 mm and irregular margins were predictors of nodule growth. The mean doubling time of 24/170 (14.1 %) growing PNs was about 4 months. Our findings suggest that baseline and follow-up CXR are pointless, and short-interval CT follow-up is warranted when PNs larger than 5 mm with irregular margins are detected on preoperative chest CT. (orig.)

  7. Thyroid nodules with highly suspicious ultrasonographic features, but with benign cytology on two occasions: is malignancy still possible?

    International Nuclear Information System (INIS)

    Rosario, Pedro Weslley; Calsolari, Maria Regina

    2016-01-01

    There is no information about the frequency of malignancy specifically in the case of thyroid nodules with highly suspicious sonographic features, but with two fine needle aspiration (FNA) showing benign cytology. This was the objective of the study. Subjects and methods: We report the results of 105 patients with thyroid nodules considered 'highly suspicious' according to the ultrasonographic classification of American Thyroid Association, in whom FNA revealed benign cytology on two occasions (interval of 6 months). Results: Thyroidectomy was performed in 11 cases due to desire of the patient or significant growth of the nodule. In these patients, cytology continued to be benign in 9, was non-diagnostic in 1, and suspicious in 1. Histology revealed papillary carcinoma in only one nodule. In patients in whom a third FNA was obtained for this study (n = 94), cytology continued to be benign in 86, became non-diagnostic in 5, indeterminate in 2, and suspicious in 1. The last 8 patients (with non-benign cytology) were submitted to thyroidectomy and histology revealed malignancy in only one nodule. Conclusion: The rate of malignancy found here for nodules with highly suspicious sonographic features, even after two FNA showing benign cytology, was 2%. We believe that in these cases, the continuation of follow-up consisting of ultrasound at intervals of 2 years may still be adequate. (author)

  8. Thyroid nodules with highly suspicious ultrasonographic features, but with benign cytology on two occasions: is malignancy still possible?

    Energy Technology Data Exchange (ETDEWEB)

    Rosario, Pedro Weslley; Calsolari, Maria Regina, E-mail: pedrowsrosario@gmail.com [Santa Casa de Belo Horizonte, MG (Brazil)

    2016-11-01

    There is no information about the frequency of malignancy specifically in the case of thyroid nodules with highly suspicious sonographic features, but with two fine needle aspiration (FNA) showing benign cytology. This was the objective of the study. Subjects and methods: We report the results of 105 patients with thyroid nodules considered 'highly suspicious' according to the ultrasonographic classification of American Thyroid Association, in whom FNA revealed benign cytology on two occasions (interval of 6 months). Results: Thyroidectomy was performed in 11 cases due to desire of the patient or significant growth of the nodule. In these patients, cytology continued to be benign in 9, was non-diagnostic in 1, and suspicious in 1. Histology revealed papillary carcinoma in only one nodule. In patients in whom a third FNA was obtained for this study (n = 94), cytology continued to be benign in 86, became non-diagnostic in 5, indeterminate in 2, and suspicious in 1. The last 8 patients (with non-benign cytology) were submitted to thyroidectomy and histology revealed malignancy in only one nodule. Conclusion: The rate of malignancy found here for nodules with highly suspicious sonographic features, even after two FNA showing benign cytology, was 2%. We believe that in these cases, the continuation of follow-up consisting of ultrasound at intervals of 2 years may still be adequate. (author)

  9. Clinical Value of Coincidence Detection Emission Tomography Using Fluoine-18-2-Fluoro-2-Deoxy-D-Glucose in the Diagnosis of Solitary Pulmonary Nodules: Correlation with Computed Tomography Findings

    International Nuclear Information System (INIS)

    Najjar, F.; Moretti, J.

    2007-01-01

    Solitary Pulmonary Nodules (size 40 mm) is the most frequent indication of coincidence detection emission tomography (CDET) with fluorine-18 fluoro-2-deoxy-D-glucose (18FDG). The aim of the present study was to establish the efficacy of this system with and without attenuation correction (AC) in correlation with computed tomography (CT) findings for the distinction between benign and malignant pulmonary nodules. Material and methods: Sixty-eight patients were included in this study. All patients presented with suspected pulmonary nodules on thoracic CT. In addition, they had CDET scan using a dual-head coincidence gamma-camera with and without measured attenuation using caesium- 137 source. Corrected images were independently interpreted from non-attenuation corrected images in a blinded manner of any clinical data. 18FDG-CDET findings were evaluated by histology when it was available. Otherwise, the final clinical outcome has been considered in data analysis. Results: A total of 71 suspected nodules were observed by CT. Malignant pulmonary disease was found in 38 of these nodules whereas 33 pulmonary nodules were proved to be benign. In addition, one malignant nodule was confirmed with negative CT findings. 18FDG-CDET imaging without AC demonstrated 48 suspected pulmonary lesions included 4 nodules with negative CT findings (sensitivity, 92%; specificity, 68.4%) Versus 43 lesions identified with AC (sensitivity, 92%; specificity, 81.5%). All of the malignant nodules >20 mm in diameter by 18FDG-CDET. In 5 patients (8% of cases), uncorrected images were spotting benign nodules which were considered as negative on corrected images. So lower specificity rate was obtained by non AC mode in comparison with AC mode (68.4% versus 81.5% respectively). Both modalities techniques failed to detect malignancy in 3 patients. In general, the diagnostic accuracy of 18FDG-CDET without AC was relatively comparable to that found with AC (82.6% to 87%, respectively).

  10. Management of solid pulmonary nodules; Management solider pulmonaler Rundherde

    Energy Technology Data Exchange (ETDEWEB)

    Poschenrieder, F.; Beyer, L.; Stroszczynski, C.; Hamer, O.W. [Universitaetsklinikum Regensburg, Institut fuer Roentgendiagnostik, Regensburg (Germany); Rehbock, B. [Praxis fuer Diagnostische Radiologie am St.-Hedwig-Krankenhaus Berlin-Mitte, Diagnostische Radiologie, Berlin (Germany); Diederich, S. [Marienhospital Duesseldorf, Institut fuer Diagnostische und Interventionelle Radiologie, Duesseldorf (Germany); Wormanns, D. [Evangelische Lungenklinik Berlin, Radiologisches Institut, Berlin (Germany)

    2014-05-15

    The increasing availability of computed tomography has meant that the number of incidentally detected solitary pulmonary nodules (SPN) has greatly increased in recent years. A reasonable management of these SPN is necessary in order to firstly be able to detect malignant lesions early on and secondly to avoid upsetting the patient unnecessarily or carrying out further stressful diagnostic procedures. This review article shows how the dignity of SPNs can be estimated and based on this how the management can be accomplished taking established guidelines into consideration. (orig.) [German] Die steigende Verfuegbarkeit leistungsstarker Computertomographen hat dazu gefuehrt, dass die Anzahl inzidentell detektierter solitaerer Lungenrundherde (''solitary pulmonary nodule'', SPN) in den letzten Jahren deutlich gestiegen ist. Diese SPN muessen einem sinnvollen Management zugefuehrt werden, um einerseits fruehzeitig auf maligne Laesionen reagieren zu koennen und andererseits bei benignen Laesionen eine unnoetige Beunruhigung des Patienten oder eine belastende weiterfuehrende Diagnostik zu vermeiden. Der Uebersichtsartikel stellt dar, wie die Dignitaet eines SPN eingeschaetzt werden kann und wie darauf basierend unter Beruecksichtigung etablierter Leitlinien das Management zielfuehrend gestaltet wird. (orig.)

  11. Proposal of a technical guide for the evaluation and management of the solitary pulmonary nodule in function of the radiological characteristics obtained by computed tomography

    International Nuclear Information System (INIS)

    Clinton Hidalgo, Carolina

    2015-01-01

    A guide is proposed to guide clinical personnel in early diagnosis, assessment and management of the solitary pulmonary nodule, with high potential of to develop lung cancer, in function of the radiological characteristics obtained by computed tomography. The management of patients with diagnosis of solitary pulmonary nodule is standardized with the purpose of to unify diagnostic criteria in a multidisciplinary and institutional environment. Tomographic radiological characteristics are described to allow the suspicion of the solitary pulmonary nodule benignity or malignity. A flow diagram is developed to guide the physician to an adequate monitoring, control and eventual therapeutic treatment. A clear and structured perspective of the diagnostic and therapeutic process is provided to the treating physician and patient [es

  12. Radiofrequency ablation of benign symptomatic thyroid nodules: prospective safety and efficacy study.

    Science.gov (United States)

    Ugurlu, M Umit; Uprak, Kivilcim; Akpinar, Ihsan N; Attaallah, Wafi; Yegen, Cumhur; Gulluoglu, Bahadir M

    2015-04-01

    Radiofrequency ablation (RFA) is a relatively novel procedure in the management of benign nodular goiter. This study was conducted to evaluate the safety and efficacy of ultrasound (US)-guided percutaneous RFA for benign symptomatic thyroid nodules as an alternative to surgery. The study involved patients for whom a fine needle aspiration biopsy had proved a diagnosis of benign nodular goiter and had nodule-related symptoms such as dysphagia, cosmetic problems, sensation of foreign body in the neck, hyperthyroidism due to autonomous nodules or fear of malignancy. Percutaneous RFA was performed as an outpatient procedure under local anesthesia. The primary outcome was an evaluation of the changes in symptom scores (0-10) for pain, dysphagia and foreign body sensation at the 1st, 3rd, and 6th months after the RFA procedure. Secondary outcomes were assessing volume changes in nodules, complication rates, and changes in thyroid function status. A total of 33 patients (24% female, 76% male) and a total of 65 nodules were included into the study. More than one nodule was treated in 63.6% of the patients. We found a statistically significant improvement from baseline to values at the 1st, 3rd, and 6th months, respectively, as follows: pain scores (2.9 ± 2.7, 2.3 ± 2.01, 1.8 ± 1.7, and 1.5 ± 1.2, p 0.005), dysphagia scores (3.9 ± 2.7, 2.6 ± 1.9; 1.7 ± 1.6, and 1.1 ± 0.3, p 0.032), and foreign body sensation scores 3.6 ± 3, 2.5 ± 2.2; 1.6 ± 1.5, and 1.1 ± 0.4, p 0.002).The mean pre-treatment nodule volume was 7.3 ± 8.3 mL. There was a statistically significant size reduction in the nodules at the 1st, 3rd, and 6th months after RFA (3.5 ± 3.8, 2.7 ± 3.4, and 1.2 ± 1.7 mL, p 0.002). The volume reduction was found to be 74% at 6th months following the RFA (p 0.005). 8 patients had autonomously functioning nodules in the pre-treatment period, 50% (n: 4) became euthyroid at the 6th month after RFA. There were no complaints other than pain (12%). RFA can be an

  13. Ultrasound guided percutaneous microwave ablation of benign thyroid nodules: Safety and imaging follow-up in 222 patients

    Energy Technology Data Exchange (ETDEWEB)

    Yue, Wenwen [Binzhou Medical University, #346 Guan-hai Road, Lai-shan, Yantai, Shandong 264003 (China); Wang, Shurong, E-mail: 7762808@sina.com [Department of Ultrasound, Muping Area People' s Hospital, #629 Nan-hua Street, Mu-ping, Yantai, Shandong 264100 (China); Wang, Bin [Binzhou Medical University, #346 Guan-hai Road, Lai-shan, Yantai, Shandong 264003 (China); Xu, Qingling; Yu, Shoujun; Yonglin, Zhang; Wang, Xiju [Department of Ultrasound, Muping Area People' s Hospital, #629 Nan-hua Street, Mu-ping, Yantai, Shandong 264100 (China)

    2013-01-15

    Objective: Microwave ablation is a minimally invasive technique that has been used to treat benign and malignant tumors of liver, lung and kidney. Towards thyroid nodules, only a few cases are reported so far. The aim of the study was to investigate the effectiveness and safety of ultrasound-guided percutaneous microwave ablation in the treatment of benign thyroid nodules with a large sample. Materials and methods: A total of 477 benign thyroid nodules in 222 patients underwent microwave ablation in our department from July 2009 to March 2012. Microwave ablation was carried out using microwave antenna (16G) under local anesthesia. Nodule volume, thyroid function and clinical symptoms were evaluated before treatment and at 1, 3, more than 6 months. The study was ethics committee approved and written informed consents were obtained from all patients. Results: All thyroid nodules significantly decreased in size after microwave ablation. A 6-month follow-up was achieved in 254 of 477 nodules, and the mean decrease in the volume of thyroid nodules was from 2.13 ± 4.42 ml to 0.45 ± 0.90 ml, with a mean percent decrease of 0.65 ± 0.65. A volume-reduction ratio greater than 50% was observed in 82.3% (209/254) of index nodules, and 30.7% (78/254) of index nodules disappeared 6-month after the ablation. The treatment was well tolerated and no major complications were observed except pain and transient voice changes. Conclusions: Microwave ablation seems to be a safe and effective technique for the treatment of benign thyroid nodules. Further prospective randomized studies are needed to define the role of the procedure in the treatment of thyroid nodules.

  14. The effects of computed tomography with iterative reconstruction on solid pulmonary nodule volume quantification.

    Directory of Open Access Journals (Sweden)

    Martin J Willemink

    Full Text Available BACKGROUND: The objectives of this study were to evaluate the influence of iterative reconstruction (IR on pulmonary nodule volumetry with chest computed tomography (CT. METHODS: Twenty patients (12 women and 8 men, mean age 61.9, range 32-87 underwent evaluation of pulmonary nodules with a 64-slice CT-scanner. Data were reconstructed using filtered back projection (FBP and IR (Philips Healthcare, iDose(4-levels 2, 4 and 6 at similar radiation dose. Volumetric nodule measurements were performed with semi-automatic software on thin slice reconstructions. Only solid pulmonary nodules were measured, no additional selection criteria were used for the nature of nodules. For intra-observer and inter-observer variability, measurements were performed once by one observer and twice by another observer. Algorithms were compared using the concordance correlation-coefficient (pc and Friedman-test, and post-hoc analysis with the Wilcoxon-signed ranks-test with Bonferroni-correction (significance-level p<0.017. RESULTS: Seventy-eight nodules were present including 56 small nodules (volume<200 mm(3, diameter<8 mm and 22 large nodules (volume≥200 mm(3, diameter≥8 mm. No significant differences in measured pulmonary nodule volumes between FBP, iDose(4-levels 2, 4 and 6 were found in both small nodules and large nodules. FBP and iDose(4-levels 2, 4 and 6 were correlated with pc-values of 0.98 or higher for both small and large nodules. Pc-values of intra-observer and inter-observer variability were 0.98 or higher. CONCLUSIONS: Measurements of solid pulmonary nodule volume measured with standard-FBP were comparable with IR, regardless of the IR-level and no significant differences between measured volumes of both small and large solid nodules were found.

  15. US-guided percutaneous radiofrequency thermal ablation for the treatment of solid benign hyperfunctioning or compressive thyroid nodules.

    Science.gov (United States)

    Deandrea, Maurilio; Limone, Paolo; Basso, Edoardo; Mormile, Alberto; Ragazzoni, Federico; Gamarra, Elena; Spiezia, Stefano; Faggiano, Antongiulio; Colao, Annamaria; Molinari, Filippo; Garberoglio, Roberto

    2008-05-01

    The aim of the study was to define the effectiveness and safety of ultrasound-guided percutaneous radiofrequency (RF) thermal ablation in the treatment of compressive solid benign thyroid nodules. Thirty-one patients not eligible for surgery or radioiodine (131I) treatment underwent RF ablation for benign nodules; a total of 33 nodules were treated (2 patients had 2 nodules treated in the same session): 10 cold nodules and 23 hyperfunctioning. Fourteen patients complained of compressive symptoms. Nodule volume, thyroid function and compressive symptoms were evaluated before treatment and at 1, 3 and 6 mo. Ultrasound-guided RF ablation was performed using a Starbust RITA needle, with nine expandable prongs; total exposure time was 6 to 10 min at 95 degrees C in one area or more of the nodule. Baseline volume (measured at the time of RF ablation) was 27.7 +/- 21.5 mL (mean +/- SD), but significantly decreased during follow-up: 19.2 +/- 16.2 at 1 mo (-32.7%; p nodules remained euthyroid: five patients with hot nodules normalized thyroid function, and the remaining sixteen showed a partial remission of hyperthyroidism. Besides a sensation of heat and mild swelling of the neck, no major complications were observed. Improvement in compressive symptoms was reported by 13 patients, with a reduction on severity scale from 6.1 +/- 1.4 to 2.2 +/- 1.9 (p nodules. Hyperfunction was fully controlled in 24% of patients and partially reduced in the others.

  16. Solitary pulmonary nodules: Comparison of dynamic first-pass contrast-enhanced perfusion area-detector CT, dynamic first-pass contrast-enhanced MR imaging, and FDG PET/CT.

    Science.gov (United States)

    Ohno, Yoshiharu; Nishio, Mizuho; Koyama, Hisanobu; Seki, Shinichiro; Tsubakimoto, Maho; Fujisawa, Yasuko; Yoshikawa, Takeshi; Matsumoto, Sumiaki; Sugimura, Kazuro

    2015-02-01

    To prospectively compare the capabilities of dynamic perfusion area-detector computed tomography (CT), dynamic magnetic resonance (MR) imaging, and positron emission tomography (PET) combined with CT (PET/CT) with use of fluorine 18 fluorodeoxyglucose (FDG) for the diagnosis of solitary pulmonary nodules. The institutional review board approved this study, and written informed consent was obtained from each subject. A total of 198 consecutive patients with 218 nodules prospectively underwent dynamic perfusion area-detector CT, dynamic MR imaging, FDG PET/CT, and microbacterial and/or pathologic examinations. Nodules were classified into three groups: malignant nodules (n = 133) and benign nodules with low (n = 53) or high (n = 32) biologic activity. Total perfusion was determined with dual-input maximum slope models at area-detector CT, maximum and slope of enhancement ratio at MR imaging, and maximum standardized uptake value (SUVmax) at PET/CT. Next, all indexes for malignant and benign nodules were compared with the Tukey honest significant difference test. Then, receiver operating characteristic analysis was performed for each index. Finally, sensitivity, specificity, and accuracy were compared with the McNemar test. All indexes showed significant differences between malignant nodules and benign nodules with low biologic activity (P Dynamic perfusion area-detector CT is more specific and accurate than dynamic MR imaging and FDG PET/CT in the diagnosis of solitary pulmonary nodules in routine clinical practice. © RSNA, 2014.

  17. Usefulness of the CAD System for Detecting Pulmonary Nodule in Real Clinical Practice

    International Nuclear Information System (INIS)

    Song, Kyoung Doo; Chung, Myung Jin; Kim, Hee Cheol; Lee, Kyung Soo; Jeong, Sun Young

    2011-01-01

    We wanted to evaluate the usefulness of the computer-aided detection (CAD) system for detecting pulmonary nodules in real clinical practice by using the CT images. Our Institutional Review Board approved our retrospective study with a waiver of informed consent. This study included 166 CT examinations that were performed for the evaluation of pulmonary metastasis in 166 patients with colorectal cancer. All the CT examinations were interpreted by radiologists and they were also evaluated by the CAD system. All the nodules detected by the CAD system were evaluated with regard to whether or not they were true nodules, and they were classified into micro nodules (MN, diameter < 4 mm) and significant nodules (SN, 4 ≤ diameter ≤ 10 mm). The radiologic reports and CAD results were compared. The CAD system helped detect 426 nodules: 115 (27%) of the 426 nodules were classified as true nodules and 35 (30%) of the 115 nodules were SNs, and 83 (72%) of the 115 were not mentioned in the radiologists' reports and three (4%) of the 83 nodules were non-calcified SNs. One of three non-calcified SNs was confirmed as a metastatic nodule. According to the radiologists' reports, 60 true nodules were detected, and 28 of the 60 were not detected by the CAD system. Although the CAD system missed many SNs that are detected by radiologists, it helps detect additional nodules that are missed by the radiologists in real clinical practice. Therefore, the CAD system can be useful to support a radiologist's detection performance

  18. Bipolar radiofrequency ablation of benign thyroid nodules using a multiple overlapping shot technique in a 3-month follow-up.

    Science.gov (United States)

    Kohlhase, Konstantin David; Korkusuz, Yücel; Gröner, Daniel; Erbelding, Christian; Happel, Christian; Luboldt, Wolfgang; Grünwald, Frank

    2016-08-01

    Purpose The aim of this study was to evaluate the decrease of benign thyroid nodules after bipolar radiofrequency ablation (RFA) in a 3-month follow-up using a multiple overlapping shot technique ('MOST'). Methods A total of 18 patients with 20 symptomatic benign thyroid nodules (17 cold nodules, 3 hyperfunctioning nodules) were treated in one single session by bipolar RFA. Bipolar ablation was performed using MOST. The nodule volumes were measured prior to ablation and 3 months after the procedure using ultrasound. The population consisted of either solid (>80% solid tissue within the volume of interest), complex, or cystic nodules (nodule volume (ΔV), median 5.3 mL (range 0.13-43.1 mL), corresponding to a relative reduction in mean of 56 ± 17.9%. Median initial volume was 8 mL (range 0.48-62 mL); 3 months after ablation a median volume of 2.3 mL (range 0.3-32 mL) was measured. Nodule growth ≥50% occurred in 70% (14 nodules). At the follow-up no complications such as infections, persisting pain, nerve injuries or immunogen stimulation occurred. Patients with cold nodules (15) remained euthyroid, with hyperfunctioning nodules either euthyroid (2) or latent hypofunctional (1). Conclusion The use of bipolar RFA is an effective, safe and suitable thermoablative technique to treat benign thyroid nodules. Combined with the multiple overlapping shot technique it allows sufficient ablation.

  19. Return of the pulmonary nodule: the radiologist's key role in implementing the 2015 BTS guidelines on the investigation and management of pulmonary nodules.

    Science.gov (United States)

    Graham, Richard N J; Baldwin, David R; Callister, Matthew E J; Gleeson, Fergus V

    2016-01-01

    The British Thoracic Society has published new comprehensive guidelines for the management of pulmonary nodules. These guidelines are significantly different from those previously published, as they use two malignancy prediction calculators to better characterize the risk of malignancy. There are recommendations for a higher nodule size threshold for follow-up (≥5 mm or ≥80 mm(3)) and a reduction of the follow-up period to 1 year for solid pulmonary nodules; both of these will reduce the number of follow-up CT scans. PET-CT plays a crucial role in characterization also, with an ordinal scale being recommended for reporting. Radiologists will be the key in implementing these guidelines, and routine use of volumetric image-analysis software will be required to manage patients with pulmonary nodules correctly.

  20. Dual-energy CT in the evaluation of solitary pulmonary nodules by virtual non-enhanced images: initial experience

    International Nuclear Information System (INIS)

    Guo Xing; Ding Wei; Qin Huijuan

    2011-01-01

    Objective: To determine the accuracy and radiation dose of dual-energy computed tomography (CT) in evaluating solitary pulmonary nodules (SPNs) by virtual non-enhanced images. Methods: Sixty-one patients with SPNs including 39 malignant and 18 benign nodules proved by pathology underwent DECT scans. The CT values of SPNs on enhanced weighted average and virtual non-enhanced images were compared by using Liver VNC processing unit in terms of their diagnostic accuracy for distinguishing malignant and benign nodules with a 20 HU threshold. Diagnostic accuracy was compared. In 28 patients of all patients, image noise and quality score of the non-enhanced and virtual non-enhanced images were compared, and radiation doses of each patient were recorded. The paired t test was used to analyze the noise difference between the plain scan and virtual non-enhanced scan. The Mann-Whitney U test. was used to analyze statistically significant differences of the image quality score and radiation dose between the non-enhanced scan and virtual non-enhanced scan. Results: The sensitivity, specificity and accuracy for distinguishing benign and malignant nodules by using the virtual non-enhanced image of were 89.7% (35/39), 72.2% (13/18), 84.2% (48/57) respectively. The noise of common CT and virtual non- enhanced images were (8.49±1.94) HU and (10.14±2.18) HU, and there were statistically difference (t=9.45, P 0.05). The radiation doses of common CT and DECT were (3.72±0.48) mSv and (3.78±0.45) mSv, and there were no statistical difference (U= 350.50, P>0.05). Conclusion: DECT by using virtual non-enhanced images is useful tool to distinguish the benign and malignant SPN without additional radiation dose. (authors)

  1. {sup 99m}Tc-EDDA/HYNIC-TOC scintigraphy in the differential diagnosis of solitary pulmonary nodules

    Energy Technology Data Exchange (ETDEWEB)

    Plachcinska, Anna; Kusmierek, Jacek [Department of Nuclear Medicine, Medical University, ul.Czechoslowacka 8/10, 92-216, Lodz (Poland); Mikolajczak, Renata [Radioisotope Centre POLATOM, Otwock-Swierk (Poland); Maecke, Helmut R. [Radiological Chemistry Unit, Kantonspital Basel, Basel (Switzerland); Michalski, Andrzej; Rzeszutek, Katarzyna [Centre for Treatment of Pulmonary Diseases, Lodz (Poland); Kozak, Jozef [Thoracic Surgery Ward, Copernicus Hospital, Lodz (Poland)

    2004-07-01

    Forty-three consecutive patients with solitary pulmonary nodules (SPNs) on chest radiographs were studied scintigraphically after administration of the somatostatin analogue {sup 99m}Tc-EDDA/HYNIC-TOC. The objective of the study was to assess the usefulness of the procedure for differentiation of SPNs as malignant or benign. The administered activity was 740-925 MBq, and a single-photon emission computed tomography imaging technique was employed. Verification of the nodule aetiology was based on histology or cytology and bacteriology. A stable tumour size on chest radiography for at least 3 years was accepted as an additional criterion of benignity. In 29 patients, nodules were found to be malignant. The diagnoses included ten adenocarcinomas, five squamous cell carcinomas, two large cell carcinomas, six non-small cell lung cancers without specification of the more detailed morphology, two small cell lung cancers, two typical carcinoids and two metastatic tumours (leiomyosarcoma and malignant melanoma). In 14 patients the following benign tumours were diagnosed: four tuberculomas, one other granuloma, three hamartomas, one non-specific inflammatory infiltrate, one abscess, one peripheral carcinoid with the morphological characteristics of a benign tumour, one ectopic lesion of thyroid tissue and two benign tumours of unspecified aetiology with a stable size over 3 and 5 years respectively. Positive scintigraphic results were obtained in 26 of the 29 patients (90%) with malignant SPNs; among these, 24 of the 25 (96%) cases of primary pulmonary carcinoma yielded positive results. The remaining two false negative cases were the metastatic tumours, liposarcoma and melanoma. Of the 14 benign lesions, ten (71%) did not accumulate the radiopharmaceutical. The remaining four benign tumours that were visible on scintigrams comprised one tuberculoma, one hamartoma, one abscess and one case in which the diagnosis could not be established (the tumour had a stable size over 3

  2. Persistent pulmonary subsolid nodules: model-based iterative reconstruction for nodule classification and measurement variability on low-dose CT

    International Nuclear Information System (INIS)

    Kim, Hyungjin; Kim, Seong Ho; Lee, Sang Min; Lee, Kyung Hee; Park, Chang Min; Park, Sang Joon; Goo, Jin Mo

    2014-01-01

    To compare the pulmonary subsolid nodule (SSN) classification agreement and measurement variability between filtered back projection (FBP) and model-based iterative reconstruction (MBIR). Low-dose CTs were reconstructed using FBP and MBIR for 47 patients with 47 SSNs. Two readers independently classified SSNs into pure or part-solid ground-glass nodules, and measured the size of the whole nodule and solid portion twice on both reconstruction algorithms. Nodule classification agreement was analyzed using Cohen's kappa and compared between reconstruction algorithms using McNemar's test. Measurement variability was investigated using Bland-Altman analysis and compared with the paired t-test. Cohen's kappa for inter-reader SSN classification agreement was 0.541-0.662 on FBP and 0.778-0.866 on MBIR. Between the two readers, nodule classification was consistent in 79.8 % (75/94) with FBP and 91.5 % (86/94) with MBIR (p = 0.027). Inter-reader measurement variability range was -5.0-2.1 mm on FBP and -3.3-1.8 mm on MBIR for whole nodule size, and was -6.5-0.9 mm on FBP and -5.5-1.5 mm on MBIR for solid portion size. Inter-reader measurement differences were significantly smaller on MBIR (p = 0.027, whole nodule; p = 0.011, solid portion). MBIR significantly improved SSN classification agreement and reduced measurement variability of both whole nodules and solid portions between readers. (orig.)

  3. Pneumocystis Pneumonia Presenting as an Enlarging Solitary Pulmonary Nodule

    Directory of Open Access Journals (Sweden)

    Krunal Bharat Patel

    2016-01-01

    Full Text Available Pneumocystis pneumonia is a life threatening infection that usually presents with diffuse bilateral ground-glass infiltrates in immunocompromised patients. We report a case of a single nodular granulomatous Pneumocystis pneumonia in a male with diffuse large B-cell lymphoma after R-CHOP therapy. He presented with symptoms of productive cough, dyspnea, and right-sided pleuritic chest pain that failed to resolve despite treatment with multiple antibiotics. Chest X-ray revealed right lower lobe atelectasis and CT of chest showed development of 2 cm nodular opacity with ground-glass opacities. Patient underwent bronchoscopy and biopsy that revealed granulomatous inflammation in a background of organizing pneumonia pattern with negative cultures. Respiratory symptoms resolved but the solitary nodular opacity increased in size prompting a surgical wedge resection which revealed granulomatous Pneumocystis pneumonia infection. This case is the third documented report of Pneumocystis pneumonia infection within a solitary pulmonary nodule in an individual with hematologic neoplasm. Although Pneumocystis pneumonia most commonly occurs in patients with HIV/acquired immunodeficiency syndrome and with diffuse infiltrates, the diagnosis should not be overlooked when only a solitary nodule is present.

  4. Multicentre external validation of the BIMC model for solid solitary pulmonary nodule malignancy prediction

    Energy Technology Data Exchange (ETDEWEB)

    Soardi, Gian Alberto; Perandini, Simone; Motton, Massimiliano; Montemezzi, Stefania [AOUI Verona, UOC Radiologia, Ospedale Maggiore di Borgo Trento, Verona (Italy); Larici, Anna Rita; Del Ciello, Annemilia [Universita Cattolica del Sacro Cuore, Dipartimento di Scienze Radiologiche, Roma (Italy); Rizzardi, Giovanna [UO Chirurgia Toracica, Ospedale Humanitas Gavazzeni, Bergamo (Italy); Solazzo, Antonio [UO Radiologia, Ospedale Humanitas Gavazzeni, Bergamo (Italy); Mancino, Laura [UO Pneumologia, Ospedale dell' Angelo di Mestre, Mestre (Italy); Bernhart, Marco [UO Radiologia, Ospedale dell' Angelo di Mestre, Mestre (Italy)

    2017-05-15

    To provide multicentre external validation of the Bayesian Inference Malignancy Calculator (BIMC) model by assessing diagnostic accuracy in a cohort of solitary pulmonary nodules (SPNs) collected in a clinic-based setting. To assess model impact on SPN decision analysis and to compare findings with those obtained via the Mayo Clinic model. Clinical and imaging data were retrospectively collected from 200 patients from three centres. Accuracy was assessed by means of receiver-operating characteristic (ROC) areas under the curve (AUCs). Decision analysis was performed by adopting both the American College of Chest Physicians (ACCP) and the British Thoracic Society (BTS) risk thresholds. ROC analysis showed an AUC of 0.880 (95 % CI, 0.832-0.928) for the BIMC model and of 0.604 (95 % CI, 0.524-0.683) for the Mayo Clinic model. Difference was 0.276 (95 % CI, 0.190-0.363, P < 0.0001). Decision analysis showed a slightly reduced number of false-negative and false-positive results when using ACCP risk thresholds. The BIMC model proved to be an accurate tool when characterising SPNs. In a clinical setting it can distinguish malignancies from benign nodules with minimal errors by adopting current ACCP or BTS risk thresholds and guiding lesion-tailored diagnostic and interventional procedures during the work-up. (orig.)

  5. Level-set segmentation of pulmonary nodules in megavolt electronic portal images using a CT prior

    International Nuclear Information System (INIS)

    Schildkraut, J. S.; Prosser, N.; Savakis, A.; Gomez, J.; Nazareth, D.; Singh, A. K.; Malhotra, H. K.

    2010-01-01

    Purpose: Pulmonary nodules present unique problems during radiation treatment due to nodule position uncertainty that is caused by respiration. The radiation field has to be enlarged to account for nodule motion during treatment. The purpose of this work is to provide a method of locating a pulmonary nodule in a megavolt portal image that can be used to reduce the internal target volume (ITV) during radiation therapy. A reduction in the ITV would result in a decrease in radiation toxicity to healthy tissue. Methods: Eight patients with nonsmall cell lung cancer were used in this study. CT scans that include the pulmonary nodule were captured with a GE Healthcare LightSpeed RT 16 scanner. Megavolt portal images were acquired with a Varian Trilogy unit equipped with an AS1000 electronic portal imaging device. The nodule localization method uses grayscale morphological filtering and level-set segmentation with a prior. The treatment-time portion of the algorithm is implemented on a graphical processing unit. Results: The method was retrospectively tested on eight cases that include a total of 151 megavolt portal image frames. The method reduced the nodule position uncertainty by an average of 40% for seven out of the eight cases. The treatment phase portion of the method has a subsecond execution time that makes it suitable for near-real-time nodule localization. Conclusions: A method was developed to localize a pulmonary nodule in a megavolt portal image. The method uses the characteristics of the nodule in a prior CT scan to enhance the nodule in the portal image and to identify the nodule region by level-set segmentation. In a retrospective study, the method reduced the nodule position uncertainty by an average of 40% for seven out of the eight cases studied.

  6. Differential diagnosis of a solitary pulmonary nodule of the lung on the grounds of selected laboratory tests and radiological examination

    International Nuclear Information System (INIS)

    Szlachcinska, A.; Kozak, J.

    2011-01-01

    Objective: To present in detail the diagnosis of solitary pulmonary nodule and especially evaluation of: clinical data, analysis of radiological images, selected laboratory tests. Material and methods: There were 50 patients - 31 men and 19 women at the mean age 58.7 ± 11.4 years old who underwent surgical treatment because of a solitary pulmonary nodule. Interview, physical examination, computed tomography, bronchoscopy, spirometry, and laboratory tests needed for the operation were performed in all these patients. Additionally LDH, fibrinogen, ESR, and the tumour markers CEA, Ca 15-3, Ca 19-9, NSE, SCC, and Cyfra 21-1 were measured from the blood sample collected during admission. Results: Malignant tumour was diagnosed in 24 patients, benign in 26. There is a significant difference between patients with malignant and nonmalignant tumours in age (54.46 years vs. 63.33 years), size of the tumour in the lung scan of chest CT (1.53 cm vs. 1.91 cm) and location (lower right lobe vs. upper right lobe). There is no significant difference between type of tumour and sex, clinical symptoms and laboratory tests. Conclusions: 1. The risk factors of malignancy in patient with solitary pulmonary nodule are: age ≥ 56.5 years, size of the tumour in the lung scan of chest CT ≥ 1.45 cm, location in upper right lobe. 2. LDH, fibrinogen, ESR, and the tumour markers CEA, Ca 15-3, Ca 19-9, NSE, SCC, and Cyfra 21-1 are not useful in differential diagnosis of solitary pulmonary nodule. (authors)

  7. Prevalence and configuration of pulmonary nodules on multi-row CT in children without malignant diseases

    Energy Technology Data Exchange (ETDEWEB)

    Renne, Julius; Wacker, Frank; Berthold, Lars-Daniel; Weidemann, Juergen [Hannover Medical School, Institute for Diagnostic and Interventional Radiology, Hannover (Germany); Linderkamp, Christin [Hannover Medical School, Pediatric Oncology, Hannover (Germany)

    2015-09-15

    To assess the prevalence and morphologic characterization of pulmonary nodules in children on a chest computed tomography (CT). Two hundred and fifty-nine trauma chest CTs in children aged 0-18 years were retrospectively reviewed by two radiologists, each with more than 10 years of experience. Images were acquired on a 64-row CT. Pulmonary lobes with trauma affections such as contusion or haemorrhage were excluded. All pulmonary nodules were evaluated for distance from the pleural surface, location, calcification and size on axial slices. A total of 1,190/1,295 (92 %) pulmonary lobes without traumatic injury were included in this study. In 86 of 259 (33 %) patients, 131 pulmonary nodules were detected. Number of nodules per patient ranged from 1 to 4. Calcifications were seen in 19 % (25) of all nodules. Diameters ranged from 1 to 5 mm. 59 % (77) were located in the lower lobes, 9 % (12) in the middle lobe and 32 % (42) in the upper lobes. 84 % of the non-calcified nodules >2 mm showed a slightly angular or triangular (mostly pleural nodes) shape. Pulmonary nodules smaller than 5 mm can be detected frequently in children without malignant disease and are predominantly located in the lower lobes. (orig.)

  8. Severe Cushing's syndrome and bilateral pulmonary nodules: beyond ectopic ACTH.

    Science.gov (United States)

    Tavares Bello, Carlos; van der Poest Clement, Emma; Feelders, Richard

    2017-01-01

    Cushing's syndrome is a rare disease that results from prolonged exposure to supraphysiological levels of glucocorticoids. Severe and rapidly progressive cases are often, but not exclusively, attributable to ectopic ACTH secretion. Extreme hypercortisolism usually has florid metabolic consequences and is associated with an increased infectious and thrombotic risk. The authors report on a case of a 51-year-old male that presented with severe Cushing's syndrome secondary to an ACTH-secreting pituitary macroadenoma, whose diagnostic workup was affected by concurrent subclinical multifocal pulmonary infectious nodules. The case is noteworthy for the atypically severe presentation of Cushing's disease, and it should remind the clinician of the possible infectious and thrombotic complications associated with Cushing's syndrome. Severe Cushing's syndrome is not always caused by ectopic ACTH secretion.Hypercortisolism is a state of immunosuppression, being associated with an increased risk for opportunistic infections.Infectious pulmonary infiltrates may lead to imaging diagnostic dilemmas when investigating a suspected ectopic ACTH secretion.Cushing's syndrome carries an increased thromboembolic risk that may even persist after successful surgical management.Antibiotic and venous thromboembolism prophylaxis should be considered in every patient with severe Cushing's syndrome.

  9. Spontaneous Regression of Pulmonary Nodules Presenting as Epstein-Barr Virus-related Atypical Infectious Mononucleosis.

    Science.gov (United States)

    Shinozuka, Jun; Awaguni, Hitoshi; Tanaka, Shin-Ichiro; Makino, Shigeru; Maruyama, Rikken; Inaba, Tohru; Imashuku, Shinsaku

    2016-07-01

    Pulmonary nodules associated with Epstein-Barr virus (EBV)-related atypical infectious mononucleosis have rarely been described. A 12-year-old Japanese boy, upon admission, revealed multiple small round nodules (a total of 7 nodules in 4 to 8 mm size) in the lungs on computed tomography. The hemorrhagic pharyngeal tonsils with hot signals on 18F-fluorodeoxyglucose-positron emission tomography-computed tomography were biopsied revealing the presence of EBV-encoded small nuclear RNA (EBER)-positive cells; however, no lymphoma was noted. The patient was diagnosed as having atypical EBV-infectious mononucleosis associated with primary EBV infection. Pulmonary nodules markedly reduced in numbers and sizes spontaneously over a 2-year period. Differential diagnosis of pulmonary nodules in childhood should include atypical EBV infection.

  10. Prediction models for solitary pulmonary nodules based on curvelet textural features and clinical parameters.

    Science.gov (United States)

    Wang, Jing-Jing; Wu, Hai-Feng; Sun, Tao; Li, Xia; Wang, Wei; Tao, Li-Xin; Huo, Da; Lv, Ping-Xin; He, Wen; Guo, Xiu-Hua

    2013-01-01

    Lung cancer, one of the leading causes of cancer-related deaths, usually appears as solitary pulmonary nodules (SPNs) which are hard to diagnose using the naked eye. In this paper, curvelet-based textural features and clinical parameters are used with three prediction models [a multilevel model, a least absolute shrinkage and selection operator (LASSO) regression method, and a support vector machine (SVM)] to improve the diagnosis of benign and malignant SPNs. Dimensionality reduction of the original curvelet-based textural features was achieved using principal component analysis. In addition, non-conditional logistical regression was used to find clinical predictors among demographic parameters and morphological features. The results showed that, combined with 11 clinical predictors, the accuracy rates using 12 principal components were higher than those using the original curvelet-based textural features. To evaluate the models, 10-fold cross validation and back substitution were applied. The results obtained, respectively, were 0.8549 and 0.9221 for the LASSO method, 0.9443 and 0.9831 for SVM, and 0.8722 and 0.9722 for the multilevel model. All in all, it was found that using curvelet-based textural features after dimensionality reduction and using clinical predictors, the highest accuracy rate was achieved with SVM. The method may be used as an auxiliary tool to differentiate between benign and malignant SPNs in CT images.

  11. Resection of pulmonary nodule in a patient with subglottic stenosis under modified spontaneous ventilation anesthesia

    DEFF Research Database (Denmark)

    Shen, Jianfei; Chen, Xuewei; Liang, Lixia

    2017-01-01

    . Here we present a case of pulmonary nodule resection in a patient with subglottic stenosis using uniportal thoracoscopy under spontaneous ventilation anesthesia (SVA). Compared with traditional double lumen endotracheal intubation, we believe this modified technique can significantly reduce airway...

  12. Cost-effectiveness of alternative management strategies for patients with solitary pulmonary nodules.

    Science.gov (United States)

    Gould, Michael K; Sanders, Gillian D; Barnett, Paul G; Rydzak, Chara E; Maclean, Courtney C; McClellan, Mark B; Owens, Douglas K

    2003-05-06

    Positron emission tomography (PET) with 18-fluorodeoxyglucose (FDG) is a potentially useful but expensive test to diagnose solitary pulmonary nodules. To evaluate the cost-effectiveness of strategies for pulmonary nodule diagnosis and to specifically compare strategies that did and did not include FDG-PET. Decision model. Accuracy and complications of diagnostic tests were estimated by using meta-analysis and literature review. Modeled survival was based on data from a large tumor registry. Cost estimates were derived from Medicare reimbursement and other sources. All adult patients with a new, noncalcified pulmonary nodule seen on chest radiograph. Patient lifetime. Societal. 40 clinically plausible combinations of 5 diagnostic interventions, including computed tomography, FDG-PET, transthoracic needle biopsy, surgery, and watchful waiting. Costs, quality-adjusted life-years (QALYs), and incremental cost-effectiveness ratios. The cost-effectiveness of strategies depended critically on the pretest probability of malignancy. For patients with low pretest probability (26%), strategies that used FDG-PET selectively when computed tomography results were possibly malignant cost as little as 20 000 dollars per QALY gained. For patients with high pretest probability (79%), strategies that used FDG-PET selectively when computed tomography results were benign cost as little as 16 000 dollars per QALY gained. For patients with intermediate pretest probability (55%), FDG-PET strategies cost more than 220 000 dollars per QALY gained because they were more costly but only marginally more effective than computed tomography-based strategies. The choice of strategy also depended on the risk for surgical complications, the probability of nondiagnostic needle biopsy, the sensitivity of computed tomography, and patient preferences for time spent in watchful waiting. In probabilistic sensitivity analysis, FDG-PET strategies were cost saving or cost less than 100 000 dollars per QALY

  13. The influence of inspiratory effort and emphysema on pulmonary nodule volumetry reproducibility.

    Science.gov (United States)

    Moser, J B; Mak, S M; McNulty, W H; Padley, S; Nair, A; Shah, P L; Devaraj, A

    2017-11-01

    To evaluate the impact of inspiratory effort and emphysema on reproducibility of pulmonary nodule volumetry. Eighty-eight nodules in 24 patients with emphysema were studied retrospectively. All patients had undergone volumetric inspiratory and end-expiratory thoracic computed tomography (CT) for consideration of bronchoscopic lung volume reduction. Inspiratory and expiratory nodule volumes were measured using commercially available software. Local emphysema extent was established by analysing a segmentation area extended circumferentially around each nodule (quantified as percent of lung with density of -950 HU or less). Lung volumes were established using the same software. Differences in inspiratory and expiratory nodule volumes were illustrated using the Bland-Altman test. The influences of percentage reduction in lung volume at expiration, local emphysema extent, and nodule size on nodule volume variability were tested with multiple linear regression. The majority of nodules (59/88 [67%]) showed an increased volume at expiration. Mean difference in nodule volume between expiration and inspiration was +7.5% (95% confidence interval: -24.1, 39.1%). No relationships were demonstrated between nodule volume variability and emphysema extent, degree of expiration, or nodule size. Expiration causes a modest increase in volumetry-derived nodule volumes; however, the effect is unpredictable. Local emphysema extent had no significant effect on volume variability in the present cohort. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  14. Value of diffusion-weighted MR imaging using various parameters for assessment and characterization of solitary pulmonary nodules

    International Nuclear Information System (INIS)

    Koyama, Hisanobu; Ohno, Yoshiharu; Seki, Shinichiro; Nishio, Mizuho; Yoshikawa, Takeshi; Matsumoto, Sumiaki; Maniwa, Yoshimasa; Itoh, Tomoo; Nishimura, Yoshihiro; Sugimura, Kazuro

    2015-01-01

    Highlights: •Signal–intensity ratio evaluation between lesion and spinal cord is practical method. •Apparent diffusion coefficients may not contribute to the diagnosis of malignant. •True diffusion coefficients may have low potential for the differentiation. •Perfusion fractions may be less specific parameter of diagnosis of pulmonary nodule. •Choice of b values shows little impact for differentiation of pulmonary nodules. -- Abstract: Objectives: To determine the appropriate parameters and evaluation method for characterizing solitary pulmonary nodules (SPNs) using quantitative parameters of diffusion-weighted imaging (DWI). Methods: Thirty-two subjects with 36 SPNs underwent DWI with seven different b values (0, 50, 100, 150, 300, 500, and 1000 s/mm 2 ). Five quantitative parameters were obtained from the region of interest drawn over each SPN: apparent diffusion coefficients (ADCs), true diffusion coefficients (DCs), and perfusion fractions (PFs), and signal–intensity ratios between lesion and spinal cord from DWI (b values: 1000 [LSR 1000 ] and 500 [LSR 500 )]). All quantitative parameters and the diagnostic capabilities were statistically compared. Results: SPNs were diagnosed as follow: malignant (n = 27) and benign (n = 9). Parameter comparisons for malignant and benign showed both LSRs differed significantly (p < 0.05). Applying feasible threshold values showed LSR 500 specificity (88.9% [8/9]) and accuracy (77.8% [28/36]) were significantly higher than ADC, DC, and PF specificity and accuracy (p < 0.05). LSR 1000 accuracy (72.2% [26/36]) was significantly higher than DC accuracy, and its specificity (88.9% [8/9]) was significantly higher than ADC, DC, and PF specificities (p < 0.05). Conclusions: For quantitative differentiation of SPNs, LSR evaluation was more useful and practical than ADC, DC, and PF, and choice of b values showed little impact for the differentiation

  15. Value of flexible bronchoscopy in the pre-operative work-up of solitary pulmonary nodules.

    Science.gov (United States)

    Schwarz, Carsten; Schönfeld, Nicolas; Bittner, Roland C; Mairinger, Thomas; Rüssmann, Holger; Bauer, Torsten T; Kaiser, Dirk; Loddenkemper, Robert

    2013-01-01

    The diagnostic value of flexible bronchoscopy in the pre-operative work-up of solitary pulmonary nodules (SPN) is still under debate among pneumologists, radiologists and thoracic surgeons. In a prospective observational manner, flexible bronchoscopy was routinely performed in 225 patients with SPN of unknown origin. Of the 225 patients, 80.5% had lung cancer, 7.6% had metastasis of an extrapulmonary primary tumour and 12% had benign aetiology. Unsuspected endobronchial involvement was found in 4.4% of all 225 patients (or in 5.5% of patients with lung cancer). In addition, flexible bronchoscopy clarified the underlying aetiology in 41% of the cases. The bronchoscopic biopsy results from the SPN were positive in 84 (46.5%) patients with lung cancer. Surgery was cancelled due to the results of flexible bronchoscopy in four cases (involvement of the right main bronchus (impaired pulmonary function did not allow pneumonectomy) n=1, small cell lung cancer n=1, bacterial pneumonia n=2), and the surgical strategy had to be modified to bilobectomy in one patient. Flexible bronchoscopy changed the planned surgical approach in five cases substantially. These results suggest that routine flexible bronchoscopy should be included in the regular pre-operative work-up of patients with SPN.

  16. The Role of Insulin-Like Growth Factor 1 in the Development of Benign and Malignant Thyroid Nodules

    Directory of Open Access Journals (Sweden)

    Ayşe Karadayı

    2012-06-01

    Full Text Available Objective: This study aims to investigate the role of IGF-1 in the development of nodular thyroid disease. Material and Methods: A total number of 100 consecutive patients operated for nodular thyroid disease in our institution were included in this prospective study. In addition to classical pathological examinations, nodules and extranodular healthy tissues were sampled and immunochemically stained for IGF-1. The materials were independently evaluated using an Allred Scoring System ranging from 0 to 8. If the score was ≥1, the tissue was accepted as IGF-1 positive.Results: IGF-1 positivity was observed in 88% and 58% of the samples obtained from nodules and extranodular healthy tissues, respectively. Allred 8-unit scores were higher in benign nodules (n=89; 4.1±2.3 and papillary carcinomas (n=7; 6.7±1.3, than in extranodular healthy tissues in the same patients (2.3±2.3 and 3.3±1.9, respectively; and higher in papillary carcinomas than in benign nodules, when the scores were compared to each other (p<0.01 for all comparisons. Conclusions: Allred 8-unit scores for IGF-1 increase in the presence of benign thyroid nodules, papillary cancer. The results of our study support the findings of previous studies demonstrating the role of IGF-1 in the development of thyroidal nodules.

  17. An Unusual Radiologic Pattern of Cryptogenic Organizing Pneumonia: Diffuse Pulmonary Nodules in a Leukemia Patient

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Kai Hsiung; Hsu, Hsian He; Kao, Woei Yau; Chang, Ching Feng; Cheng, Ming Fang; Huang, Guo Shu [Tri-Service General Hospital, Taipei (China)

    2009-02-15

    The radiological appearance of diffuse discrete pulmonary nodules associated with cryptogenic organizing pneumonia (COP) has been rarely described. We describe a case of COP in 49-year-old woman with acute myeloid leukemia who developed diffuse pulmonary nodules during the second course of induction chemotherapy. The clinical status of the patient and imaging findings suggested the presence of a pulmonary metastasis or infectious disease. A video-assisted thoracoscopic lung biopsy resulted in the unexpected diagnosis of COP as an isolated entity. Steroid therapy led to dramatic improvement of the clinical symptoms and the pulmonary lesions.

  18. Long-term follow-up sonography of benign cystic thyroid nodules after a percutaneous ethanol injection: the incidence of malignancy-mimicking nodules

    International Nuclear Information System (INIS)

    Park, Ji Sung; Kim, Dong Wook; Eun, Choong Ki; Choi, Seok Jin; Rho, Myung Ho

    2008-01-01

    To evaluate the incidence of malignancy-mimicking sclerosed thyroid nodules, from long-term follow-up ultrasonography (US) after an US-guided percutaneous ethanol injection (PEI). We examined 86 benign cystic thyroid nodules from 80 patients. The nodules were classified into two groups based on whether an aspiration (Group A, n = 26) or non-aspiration (Group B, n 60) of infused ethanol was performed. The final follow-up US over 12 months was performed in all patients. Of the 86 nodules, the cystic portion of 82 (95.3%) cases, from 76 patients, completely disappeared subsequent to the first follow-up US (Group A, n = 24, Group B, n = 58) (Chi-square test, ρ > 0.05). Moreover, 46 sclerosed thyroid nodules showed two or more of the 'five sonographic criteria' upon a follow-up US (Group A, n = 13, 50.0%, Group B, n = 32, 53.3%). A higher ratio of the cystic portion of the nodules was associated with a higher incidence of the 'five sonographic criteria' for malignancies detected via a follow-up US (ρ < 0.01; Student's t-test). For the long-term follow-up US, the 'five sonographic criteria' were observed in half the patients who received US-guided PEI. Also, by acknowledging the possibility that sonographic findings mimic a malignancy, since the sclerosed thyroid nodule, patients may avoid an unnecessary biopsy

  19. Persistent pulmonary subsolid nodules: model-based iterative reconstruction for nodule classification and measurement variability on low-dose CT.

    Science.gov (United States)

    Kim, Hyungjin; Park, Chang Min; Kim, Seong Ho; Lee, Sang Min; Park, Sang Joon; Lee, Kyung Hee; Goo, Jin Mo

    2014-11-01

    To compare the pulmonary subsolid nodule (SSN) classification agreement and measurement variability between filtered back projection (FBP) and model-based iterative reconstruction (MBIR). Low-dose CTs were reconstructed using FBP and MBIR for 47 patients with 47 SSNs. Two readers independently classified SSNs into pure or part-solid ground-glass nodules, and measured the size of the whole nodule and solid portion twice on both reconstruction algorithms. Nodule classification agreement was analyzed using Cohen's kappa and compared between reconstruction algorithms using McNemar's test. Measurement variability was investigated using Bland-Altman analysis and compared with the paired t-test. Cohen's kappa for inter-reader SSN classification agreement was 0.541-0.662 on FBP and 0.778-0.866 on MBIR. Between the two readers, nodule classification was consistent in 79.8 % (75/94) with FBP and 91.5 % (86/94) with MBIR (p = 0.027). Inter-reader measurement variability range was -5.0-2.1 mm on FBP and -3.3-1.8 mm on MBIR for whole nodule size, and was -6.5-0.9 mm on FBP and -5.5-1.5 mm on MBIR for solid portion size. Inter-reader measurement differences were significantly smaller on MBIR (p = 0.027, whole nodule; p = 0.011, solid portion). MBIR significantly improved SSN classification agreement and reduced measurement variability of both whole nodules and solid portions between readers. • Low-dose CT using MBIR algorithm improves reproducibility in the classification of SSNs. • MBIR would enable more confident clinical planning according to the SSN type. • Reduced measurement variability on MBIR allows earlier detection of potentially malignant nodules.

  20. Effect of ultrasound-guided interstitial laser photocoagulation on benign solitary solid cold thyroid nodules - a randomised study

    DEFF Research Database (Denmark)

    Døssing, Helle; Bennedbaek, Finn Noe; Hegedüs, Laszlo

    2005-01-01

    AIM: To evaluate the efficacy of ultrasound (US)-guided interstitial laser photocoagulation (ILP) on thyroid function, nodule size and patient satisfaction in benign solitary solid cold thyroid nodules by comparing one ILP session with no treatment in a prospective randomised study. MATERIALS...... and thyroid function was determined by routine assays before and during follow-up. Pressure and cosmetic complaints before and at 6 months were evaluated on a visual analogue scale. ILP was performed under US guidance and with an output power of 2.5-3.5 W. RESULTS: In the ILP group, the nodule volume...

  1. Evaluation of benign pulmonary lesions less than 20 mm in diameter by thin-section computed tomography

    International Nuclear Information System (INIS)

    Shiotani, Seiji; Yamada, Kouzo; Oshita, Fumihiro

    1997-01-01

    To establish diagnostic criteria for small solitary pulmonary nodules, the findings of thin-section computed tomography (CT) were compared with pathological findings. We evaluated thin-section CT images and compared them with pathological findings in 23 specimens of resected benign lesions less than 20 mm in diameter located in the peripheral region. The thin-section CT images were reconstructed using 2 mm thick sections taken by TCT-900S, HELIX (Toshiba, Tokyo) and were examined with two different windows and level settings. In every case, the surgical specimens were sliced transversely to correlate with the CT findings. The thin-section CT images were classified into two types; solid and air-containing types. The former consisted of benign pulmonary tumors, granulomas and some focal fibrosis, while the latter all consisted of focal fibrosis. Both types were difficult to distinguish from peripheral lung cancer based only on margin analysis of the lesion, but analysis of how pulmonary vessels relate to the lesion can allow benign pulmonary lesions to be distinguished from peripheral lung cancer. (author)

  2. Volumetric measurements of pulmonary nodules at multi-row detector CT: in vivo reproducibility

    International Nuclear Information System (INIS)

    Wormanns, Dag; Marheine, Anke; Beyer, Florian; Heindel, Walter; Diederich, Stefan; Kohl, Gerhard; Klotz, Ernst

    2004-01-01

    The aim of this study was to assess the in vivo measurement precision of a software tool for volumetric analysis of pulmonary nodules from two consecutive low-dose multi-row detector CT scans. A total of 151 pulmonary nodules (diameter 2.2-20.5 mm, mean diameter 7.4±4.5 mm) in ten subjects with pulmonary metastases were examined with low-dose four-detector-row CT (120 kVp, 20 mAs (effective), collimation 4 x 1 mm, normalized pitch 1.75, slice thickness 1.25 mm, reconstruction increment 0.8 mm; Somatom VolumeZoom, Siemens). Two consecutive low-dose scans covering the whole lung were performed within 10 min. Nodule volume was determined for all pulmonary nodules visually detected in both scans using the volumetry tool included in the Siemens LungCare software. The 95% limits of agreement between nodule volume measurements on different scans were calculated using the Bland and Altman method for assessing measurement agreement. Intra- and interobserver agreement of volume measurement were determined using repetitive measurements of 50 randomly selected nodules at the same scan by the same and different observers. Taking into account all 151 nodules, 95% limits of agreement were -20.4 to 21.9% (standard error 1.5%); they were -19.3 to 20.4% (standard error 1.7%) for 105 nodules <10 mm. Limits of agreement were -3.9 to 5.7% for intraobserver and -5.5 to 6.6% for interobserver agreement. Precision of in vivo volumetric analysis of nodules with an automatic volumetry software tool was sufficiently high to allow for detection of clinically relevant growth in small pulmonary nodules. (orig.)

  3. Combined value of Virtual Touch tissue quantification and conventional sonographic features for differentiating benign and malignant thyroid nodules smaller than 10 mm.

    Science.gov (United States)

    Zhang, Huiping; Shi, Qiusheng; Gu, Jiying; Jiang, Luying; Bai, Min; Liu, Long; Wu, Ying; Du, Lianfang

    2014-02-01

    This study aimed to investigate the value of sonographic features including Virtual Touch tissue quantification (VTQ; Siemens Medical Solutions, Mountain View, CA) for differentiating benign and malignant thyroid nodules smaller than 10 mm. Seventy-one thyroid nodules smaller than 10 mm with pathologic diagnoses were included in this study. The conventional sonographic features and quantitative elasticity features (VTQ) were observed and compared between benign and malignant nodules. There were 39 benign and 32 malignant nodules according to histopathologic examination. When compared with benign nodules, malignant nodules were more frequently taller than wide, poorly defined, and markedly hypoechoic (P benign and malignant nodules. The VTQ value for malignant nodules (mean ± SD 3.260 ± 0.725 m/s) was significantly higher than that of benign ones (2.108 ± 0.455 m/s; P benign and malignant thyroid nodules smaller than 10 mm. When VTQ was combined with B-mode sonographic features, the sensitivity was improved significantly.

  4. Frequency and characteristics of pulmonary nodules in children at computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Samim, Atia; Littooij, Annemieke S.; Wessels, Frank J.; Nievelstein, Rutger A.J.; Jong, Pim A. de [University Medical Centre Utrecht/Wilhelmina Children' s Hospital, Department of Radiology, Utrecht (Netherlands); Heuvel-Eibrink, Marry M. van den [Princess Maxima Centre for Pediatric Oncology, Department of Pediatric Oncology, Utrecht (Netherlands)

    2017-12-15

    Normative data on pulmonary nodules in children without malignancy are limited. Knowledge of the frequency and characteristics of pulmonary nodules in healthy children can influence care decisions in children with malignant disease. To provide normative data concerning the frequency and characteristics of pulmonary nodules on computed tomography (CT) in young children. All children ages 1 year-12 years who underwent chest CT after high-energy trauma were retrospectively investigated. Exclusion criteria were a history of malignancy, thick image slices, motion artefacts and extensive post-traumatic pulmonary changes. Two radiologists were asked to independently identify all nodules and to characterize each nodule with respect to location, size, perifissural location and calcification. Discrepancies were adjudicated by a third reader, who set the reference standard in this study. Interobserver agreement in detection and characterization was assessed using the kappa coefficient (κ). Identified were 120 patients, of whom 72 (75% male; median age: 8.0 years [interquartile range: 4-11]) were included. A total of 59 pulmonary nodules were present in 27 patients (38%; 95% confidence interval: 26-49%; range: 1-5 nodules per patient, with a mean diameter of 3.2 mm [standard deviation: 0.9 mm]). For nodule detection, the per-patient interobserver agreement was substantial (κ=0.78) and per-lobe agreement was moderate (κ=0.40). For characterization, there was fair to substantial agreement (κ=0.36-0.74). Small pulmonary nodules on chest CT are a common finding in otherwise healthy children, but detection and characterization have only moderate interobserver agreement. (orig.)

  5. Frequency and characteristics of pulmonary nodules in children at computed tomography

    International Nuclear Information System (INIS)

    Samim, Atia; Littooij, Annemieke S.; Wessels, Frank J.; Nievelstein, Rutger A.J.; Jong, Pim A. de; Heuvel-Eibrink, Marry M. van den

    2017-01-01

    Normative data on pulmonary nodules in children without malignancy are limited. Knowledge of the frequency and characteristics of pulmonary nodules in healthy children can influence care decisions in children with malignant disease. To provide normative data concerning the frequency and characteristics of pulmonary nodules on computed tomography (CT) in young children. All children ages 1 year-12 years who underwent chest CT after high-energy trauma were retrospectively investigated. Exclusion criteria were a history of malignancy, thick image slices, motion artefacts and extensive post-traumatic pulmonary changes. Two radiologists were asked to independently identify all nodules and to characterize each nodule with respect to location, size, perifissural location and calcification. Discrepancies were adjudicated by a third reader, who set the reference standard in this study. Interobserver agreement in detection and characterization was assessed using the kappa coefficient (κ). Identified were 120 patients, of whom 72 (75% male; median age: 8.0 years [interquartile range: 4-11]) were included. A total of 59 pulmonary nodules were present in 27 patients (38%; 95% confidence interval: 26-49%; range: 1-5 nodules per patient, with a mean diameter of 3.2 mm [standard deviation: 0.9 mm]). For nodule detection, the per-patient interobserver agreement was substantial (κ=0.78) and per-lobe agreement was moderate (κ=0.40). For characterization, there was fair to substantial agreement (κ=0.36-0.74). Small pulmonary nodules on chest CT are a common finding in otherwise healthy children, but detection and characterization have only moderate interobserver agreement. (orig.)

  6. Discrimination method of large log-likelihood study in differential diagnosis of pulmonary diffuse mild micro-nodule

    International Nuclear Information System (INIS)

    Chen Budong; Ma Daqing; He Wen; Tang Hongqu; Qian Linxue; Zhou Ronglin

    2001-01-01

    Objective: To analyze HRCT and thin-slice CT scan findings in 150 patients with pulmonary diffuse mild micro-nodule, and to find the features with the purpose of identifying random micro-nodule, peri-lymphatic micro-nodule, and centrilobular micro-nodule. Methods: The useful features i 150 patients with pulmonary diffuse mild micro-nodule were translated into scores by means of discrimination method of large log-likelihood to identify the micro-nodular category. Results: The accuracy of diagnosis was 94.0% for random micro-nodule, 76.0% for peri-lymphatic micro-nodule, and 90.0% for centrilobular micro-nodule. Conclusion: HRCT and thin-slice CT scans were helpful in differential diagnosis of pulmonary diffuse mild micro-nodule. The discrimination method of large log-likelihood was propitious to diagnosis and differential diagnosis

  7. Does Lesion Size Affect the Value of Shear Wave Elastography for Differentiating Between Benign and Malignant Thyroid Nodules?

    Science.gov (United States)

    Wang, Fen; Chang, Cai; Chen, Min; Gao, Yi; Chen, Ya-Ling; Zhou, Shi-Chong; Li, Jia-Wei; Zhi, Wen-Xiang

    2018-03-01

    We aimed to investigate the diagnostic performance of shear wave elastography (SWE) combined with conventional ultrasonography (US) for differentiating between benign and malignant thyroid nodules of different sizes. A total of 445 thyroid nodules from 445 patients were divided into 3 groups based on diameter (group 1, ≤ 10 mm; group 2, 10-20 mm; and group 3, > 20 mm). The mean elasticity index of the whole lesion was automatically calculated, and the threshold for differentiation between benign and malignant nodules was constructed by a receiver operating characteristic curve analysis. Diagnostic performances of conventional US and SWE were compared by using pathologic results as reference standards. The mean elasticity was significantly higher in malignant versus benign nodules for all size groups. The differences in mean elasticity in the size groups were not statistically significant for malignant or benign nodules. The specificity of US combined with SWE for group 1 was significantly higher than that for groups 2 and 3 (77.8% versus 62.9% and 53.3%; P < .05), and compared with group 1, the sensitivity was significantly higher for groups 2 and 3 (92.4% and 94.3% versus 80.7%; P < .05). When SWE was added, the specificity increased and the sensitivity and diagnostic accuracy decreased for group 1, and the sensitivity increased and the specificity decreased for groups 2 and 3; however, the differences were not significant. Combined with SWE, US yielded higher specificity for nodules of 10 mm and smaller and higher sensitivity for nodules larger than 10 mm. © 2017 by the American Institute of Ultrasound in Medicine.

  8. Multilevel Contextual 3-D CNNs for False Positive Reduction in Pulmonary Nodule Detection.

    Science.gov (United States)

    Dou, Qi; Chen, Hao; Yu, Lequan; Qin, Jing; Heng, Pheng-Ann

    2017-07-01

    False positive reduction is one of the most crucial components in an automated pulmonary nodule detection system, which plays an important role in lung cancer diagnosis and early treatment. The objective of this paper is to effectively address the challenges in this task and therefore to accurately discriminate the true nodules from a large number of candidates. We propose a novel method employing three-dimensional (3-D) convolutional neural networks (CNNs) for false positive reduction in automated pulmonary nodule detection from volumetric computed tomography (CT) scans. Compared with its 2-D counterparts, the 3-D CNNs can encode richer spatial information and extract more representative features via their hierarchical architecture trained with 3-D samples. More importantly, we further propose a simple yet effective strategy to encode multilevel contextual information to meet the challenges coming with the large variations and hard mimics of pulmonary nodules. The proposed framework has been extensively validated in the LUNA16 challenge held in conjunction with ISBI 2016, where we achieved the highest competition performance metric (CPM) score in the false positive reduction track. Experimental results demonstrated the importance and effectiveness of integrating multilevel contextual information into 3-D CNN framework for automated pulmonary nodule detection in volumetric CT data. While our method is tailored for pulmonary nodule detection, the proposed framework is general and can be easily extended to many other 3-D object detection tasks from volumetric medical images, where the targeting objects have large variations and are accompanied by a number of hard mimics.

  9. CT Imaging Features in the Characterization of Non-Growing Solid Pulmonary Nodules in Non-Smokers

    International Nuclear Information System (INIS)

    Perandini, Simone; Soardi, Gian Alberto; Motton, Massimiliano; Augelli, Raffaele; Zantedeschi, Lisa; Montemezzi, Stefania

    2016-01-01

    A disappearing or persistent solid pulmonary nodule is a neglected clinical entity that still poses serious interpretative issues to date. Traditional knowledge deriving from previous reports suggests particular features, such as smooth edges or regular shape, to be significantly associated with benignity. A large number of benign nodules are reported among smokers in lung cancer screening programmes. The aim of this single-center retrospective study was to correlate specific imaging features to verify if traditional knowledge as well as more recent acquisitions regarding benign SPNs can be considered reliable in a current case series of nodules collected in a non-smoker cohort of patients. Fifty-three solid SPNs proven as non-growing during follow-up imaging were analyzed with regard to their imaging features at thin-section CT, their predicted malignancy risk according to three major risk assessment models, minimum density analysis and contrast enhanced-CT in the relative subgroups of nodules which underwent such tests. Eleven nodules disappeared during follow-up, 29 showed volume loss and 16 had a VDT of 1121 days or higher. There were 48 nodules located peripherally (85.71%). Evaluation of the enhancement after contrast media (n=29) showed mean enhancement ±SD of 25.72±35.03 HU, median of 18 HU, ranging from 0 to 190 HU. Minimum density assessment (n=30) showed mean minimum HU ±SD of −28.27±47.86 HU, median of −25 HU, ranging from −144 to 68 HU. Mean malignancy risk ±SD was 15.05±26.69% for the BIMC model, 17.22±19.00% for the Mayo Clinic model and 19.07±33.16% for the Gurney’s model. Our analysis suggests caution in using traditional knowledge when dealing with current small solid peripheral indeterminate SPNs and highlights how quantitative growth at follow-up should be the cornerstone of characterization

  10. Noninvasive Characterization of Indeterminate Pulmonary Nodules Detected on Chest High-Resolution Computed Tomography

    Science.gov (United States)

    2016-10-01

    Current Status ANALYZE Nodule Segmentation CANARY -PLUS ANALYZE AVW Surface Extraction In-house monolithic software ADMesh Surface Repair MATLAB...a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS. 1. REPORT DATE October 2016 2. REPORT TYPE Annual 3...we are currently developing a multivariate radiologic prediction model (radiologic model) using a population of benign and malignant lung nodules

  11. Diagnostic potential of real-time elastography (RTE) and shear wave elastography (SWE) to differentiate benign and malignant thyroid nodules

    Science.gov (United States)

    Hu, Xiangdong; Liu, Yujiang; Qian, Linxue

    2017-01-01

    Abstract Background: Real-time elastography (RTE) and shear wave elastography (SWE) are noninvasive and easily available imaging techniques that measure the tissue strain, and it has been reported that the sensitivity and the specificity of elastography were better in differentiating between benign and malignant thyroid nodules than conventional technologies. Methods: Relevant articles were searched in multiple databases; the comparison of elasticity index (EI) was conducted with the Review Manager 5.0. Forest plots of the sensitivity and specificity and SROC curve of RTE and SWE were performed with STATA 10.0 software. In addition, sensitivity analysis and bias analysis of the studies were conducted to examine the quality of articles; and to estimate possible publication bias, funnel plot was used and the Egger test was conducted. Results: Finally 22 articles which eventually satisfied the inclusion criteria were included in this study. After eliminating the inefficient, benign and malignant nodules were 2106 and 613, respectively. The meta-analysis suggested that the difference of EI between benign and malignant nodules was statistically significant (SMD = 2.11, 95% CI [1.67, 2.55], P benign and malignant thyroid nodules. PMID:29068996

  12. Mass Spectrometry Imaging Can Distinguish on a Proteomic Level Between Proliferative Nodules Within a Benign Congenital Nevus and Malignant Melanoma.

    Science.gov (United States)

    Lazova, Rossitza; Yang, Zhe; El Habr, Constantin; Lim, Young; Choate, Keith Adam; Seeley, Erin H; Caprioli, Richard M; Yangqun, Li

    2017-09-01

    Histopathological interpretation of proliferative nodules occurring in association with congenital melanocytic nevi can be very challenging due to their similarities with congenital malignant melanoma and malignant melanoma arising in association with congenital nevi. We hereby report a diagnostically challenging case of congenital melanocytic nevus with proliferative nodules and ulcerations, which was originally misdiagnosed as congenital malignant melanoma. Subsequent histopathological examination in consultation by one of the authors (R.L.) and mass spectrometry imaging analysis rendered a diagnosis of congenital melanocytic nevus with proliferative nodules. In this case, mass spectrometry imaging, a novel method capable of distinguishing benign from malignant melanocytic lesions on a proteomic level, was instrumental in making the diagnosis of a benign nevus. We emphasize the importance of this method as an ancillary tool in the diagnosis of difficult melanocytic lesions.

  13. Characterization of solitary pulmonary nodules with 18F-FDG PET/CT relative activity distribution analysis

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Liang; Lin, Jie; Tang, Kun; Zheng, SiSi; Yin, WeiWei; Zheng, XiangWu [The First Affiliated Hospital of Wenzhou Medical University, Division of PET/CT, Department of Radiology, Wenzhou (China); Tong, Li [The First People' s Hospital of Hefei, CT Department, Hefei (China); Li, WenFeng [The First Affiliated Hospital of Wenzhou Medical University, Department of Radiotherapy and Chemotherapy, Wenzhou (China); Cheng, DeZhi [The First Affiliated Hospital of Wenzhou Medical University, Department of Cardiothoracic Surgery, Wenzhou (China)

    2015-07-15

    To compare the capability of relative activity distribution (RAD), a new index of fluorodeoxyglucose F18 ({sup 18}F-FDG) uptake, with those of the typical markers for differentiating benign and malignant solitary pulmonary nodules (SPNs) by integrated positron emission tomography (PET)/computed tomography (CT). RAD, maximal standardised uptake value (SUV{sub max}), partial volume corrected SUV{sub max} (corrSUV{sub max}), and retention index (RI) were calculated prospectively for 115 malignant and 60 benign SPNs. Area under receiver operating characteristic curve (AUC), sensitivity, specificity, and accuracy were compared (P < 0.05). Malignant lesions (0.98 ± 0.03) had significantly lower RAD than benign lesions (1.01 ± 0.02). AUC (0.935) was significantly larger and specificity (96.67 %) was significantly higher for RAD than for SUV{sub max} (P ≤ 0.0001), corrSUV{sub max} (P < 0.0001), RI (P < 0.0001), and visual assessment (P = 0.01 and 0.002, respectively). Further, RAD had significantly higher sensitivity (92.17 %) than SUV{sub max} (P = 0.0007) and higher accuracy (93.71 %) than SUV{sub max} (P < 0.0001), corrSUV{sub max} (P < 0.0001), and RI (P = 0.002). RAD seems to be more specific and accurate than the typical markers for differentiating malignant and benign SPNs by {sup 18}F-FDG PET/CT. (orig.)

  14. Paediatric CT: the effects of increasing image noise on pulmonary nodule detection

    International Nuclear Information System (INIS)

    Punwani, Shonit; Davies, Warren; Greenhalgh, Rebecca; Humphries, Paul; Zhang, Jie

    2008-01-01

    A radiation dose of any magnitude can produce a detrimental effect manifesting as an increased risk of cancer. Cancer development may be delayed for many years following radiation exposure. Minimizing radiation dose in children is particularly important. However, reducing the dose can reduce image quality and may, therefore, hinder lesion detection. We investigated the effects of reducing the image signal-to-noise ratio (SNR) on CT lung nodule detection for a range of nodule sizes. A simulated nodule was placed at the periphery of the lung on an axial CT slice using image editing software. Multiple copies of the manipulated image were saved with various levels of superimposed noise. The image creation process was repeated for a range of nodule sizes. For a given nodule size, output images were read independently by four Fellows of The Royal College of Radiologists. The overall sensitivities in detecting nodules for the SNR ranges 0.8-0.99, 1-1.49, and 1.5-2.35 were 40.5%, 77.3% and 90.3%, respectively, and the specificities were 47.9%, 73.3% and 75%, respectively. The sensitivity for detecting lung nodules increased with nodule size and increasing SNR. There was 100% sensitivity for the detection of nodules of 4-10 mm in diameter at SNRs greater than 1.5. Reducing medical radiation doses in children is of paramount importance. For chest CT examinations this may be counterbalanced by reduced sensitivity and specificity combined with an increased uncertainty of pulmonary nodule detection. This study demonstrates that pulmonary nodules of 4 mm and greater in diameter can be detected with 100% sensitivity provided that the perceived image SNR is greater than 1.5. (orig.)

  15. Improvement of diagnostic efficiency in distinguishing the benign and malignant thyroid nodules via conventional ultrasound combined with ultrasound contrast and elastography.

    Science.gov (United States)

    Liu, Mei-Juan; Men, Yan-Ming; Zhang, Yong-Lin; Zhang, Yu-Xi; Liu, Hao

    2017-07-01

    We aimed to evaluate the diagnostic values of conventional ultrasound (US), ultrasound contrast (UC) and ultrasound elastography (UE) in distinguishing the benign and malignant thyroid nodules. A total of 100 patients with thyroid nodules receiving operative treatment were selected; they underwent the conventional US, UE and UC examinations before operation, respectively. The nodules received pathological examination after operation to distinguish benign from malignant lesions. The sensitivity, specificity and diagnostic accordance rate of each diagnostic method was evaluated by receiver operating characteristic (ROC) curve, and the area under the curve (AUC) of ROC was calculated. The manifestations of malignant thyroid nodules in conventional US examination were mostly the hypoecho, heterogeneous echo, irregular shape, unclear boundary, aspect ratio benign and malignant nodules in 2, 3 and 4 points were statistically significant (Pbenign and malignant thyroid nodules.

  16. Malignancy risk estimation of pulmonary nodules in screening CTs

    DEFF Research Database (Denmark)

    van Riel, Sarah J; Ciompi, Francesco; Winkler Wille, Mathilde M

    2017-01-01

    model (PanCan) assigned a malignancy probability score to each nodule. Performances were expressed by area under the ROC curve (AUC). Performance differences were tested using the Dorfman, Berbaum and Metz method. Seven observers assessed morphological nodule characteristics using a predefined list...

  17. Computer-aided detection and automated CT volumetry of pulmonary nodules

    International Nuclear Information System (INIS)

    Marten, Katharina; Engelke, Christoph

    2007-01-01

    With use of multislice computed tomography (MSCT), small pulmonary nodules are being detected in vast numbers, constituting the majority of all noncalcified lung nodules. Although the prevalence of lung cancers among such lesions in lung cancer screening populations is low, their isolation may contribute to increased patient survival. Computer-aided diagnosis (CAD) has emerged as a diverse set of diagnostic tools to handle the large number of images in MSCT datasets and most importantly, includes automated detection and volumetry of pulmonary nodules. Current CAD systems can significantly enhance experienced radiologists' performance and outweigh human limitations in identifying small lesions and manually measuring their diameters, augment observer consistency in the interpretation of such examinations and may thus help to detect significantly higher rates of early malignomas and give more precise estimates on chemotherapy response than can radiologists alone. In this review, we give an overview of current CAD in lung nodule detection and volumetry and discuss their relative merits and limitations. (orig.)

  18. Role of Computer Aided Diagnosis (CAD) in the detection of pulmonary nodules on 64 row multi detector computed tomography.

    Science.gov (United States)

    Prakashini, K; Babu, Satish; Rajgopal, K V; Kokila, K Raja

    2016-01-01

    To determine the overall performance of an existing CAD algorithm with thin-section computed tomography (CT) in the detection of pulmonary nodules and to evaluate detection sensitivity at a varying range of nodule density, size, and location. A cross-sectional prospective study was conducted on 20 patients with 322 suspected nodules who underwent diagnostic chest imaging using 64-row multi-detector CT. The examinations were evaluated on reconstructed images of 1.4 mm thickness and 0.7 mm interval. Detection of pulmonary nodules, initially by a radiologist of 2 years experience (RAD) and later by CAD lung nodule software was assessed. Then, CAD nodule candidates were accepted or rejected accordingly. Detected nodules were classified based on their size, density, and location. The performance of the RAD and CAD system was compared with the gold standard that is true nodules confirmed by consensus of senior RAD and CAD together. The overall sensitivity and false-positive (FP) rate of CAD software was calculated. Of the 322 suspected nodules, 221 were classified as true nodules on the consensus of senior RAD and CAD together. Of the true nodules, the RAD detected 206 (93.2%) and 202 (91.4%) by the CAD. CAD and RAD together picked up more number of nodules than either CAD or RAD alone. Overall sensitivity for nodule detection with the CAD program was 91.4%, and FP detection per patient was 5.5%. The CAD showed comparatively higher sensitivity for nodules of size 4-10 mm (93.4%) and nodules in hilar (100%) and central (96.5%) location when compared to RAD's performance. CAD performance was high in detecting pulmonary nodules including the small size and low-density nodules. CAD even with relatively high FP rate, assists and improves RAD's performance as a second reader, especially for nodules located in the central and hilar region and for small nodules by saving RADs time.

  19. A COMPREHENSIVE FRAMEWORK FOR AUTOMATIC DETECTION OF PULMONARY NODULES IN LUNG CT IMAGES

    Directory of Open Access Journals (Sweden)

    Mehdi Alilou

    2014-03-01

    Full Text Available Solitary pulmonary nodules may indicate an early stage of lung cancer. Hence, the early detection of nodules is the most efficient way for saving the lives of patients. The aim of this paper is to present a comprehensive Computer Aided Diagnosis (CADx framework for detection of the lung nodules in computed tomography images. The four major components of the developed framework are lung segmentation, identification of candidate nodules, classification and visualization. The process starts with segmentation of lung regions from the thorax. Then, inside the segmented lung regions, candidate nodules are identified using an approach based on multiple thresholds followed by morphological opening and 3D region growing algorithm. Finally, a combination of a rule-based procedure and support vector machine classifier (SVM is utilized to classify the candidate nodules. The proposed CADx method was validated on CT images of 60 patients, containing the total of 211 nodules, selected from the publicly available Lung Image Database Consortium (LIDC image dataset. Comparing to the other state of the art methods, the proposed framework demonstrated acceptable detection performance (Sensitivity: 0.80; Fp/Scan: 3.9. Furthermore, we visualize a range of anatomical structures including the 3D lung structure and the segmented nodules along with the Maximum Intensity Projection (MIP volume rendering method that will enable the radiologists to accurately and easily estimate the distance between the lung structures and the nodules which are frequently difficult at best to recognize from CT images.

  20. Combination of radiological and gray level co-occurrence matrix textural features used to distinguish solitary pulmonary nodules by computed tomography.

    Science.gov (United States)

    Wu, Haifeng; Sun, Tao; Wang, Jingjing; Li, Xia; Wang, Wei; Huo, Da; Lv, Pingxin; He, Wen; Wang, Keyang; Guo, Xiuhua

    2013-08-01

    The objective of this study was to investigate the method of the combination of radiological and textural features for the differentiation of malignant from benign solitary pulmonary nodules by computed tomography. Features including 13 gray level co-occurrence matrix textural features and 12 radiological features were extracted from 2,117 CT slices, which came from 202 (116 malignant and 86 benign) patients. Lasso-type regularization to a nonlinear regression model was applied to select predictive features and a BP artificial neural network was used to build the diagnostic model. Eight radiological and two textural features were obtained after the Lasso-type regularization procedure. Twelve radiological features alone could reach an area under the ROC curve (AUC) of 0.84 in differentiating between malignant and benign lesions. The 10 selected characters improved the AUC to 0.91. The evaluation results showed that the method of selecting radiological and textural features appears to yield more effective in the distinction of malignant from benign solitary pulmonary nodules by computed tomography.

  1. Shape based automated detection of pulmonary nodules with surface feature based false positive reduction

    International Nuclear Information System (INIS)

    Nomura, Y.; Itoh, H.; Masutani, Y.; Ohtomo, K.; Maeda, E.; Yoshikawa, T.; Hayashi, N.

    2007-01-01

    We proposed a shape based automated detection of pulmonary nodules with surface feature based false positive (FP) reduction. In the proposed system, the FP existing in internal of vessel bifurcation is removed using extracted surface of vessels and nodules. From the validation with 16 chest CT scans, we find that the proposed CAD system achieves 18.7 FPs/scan at 90% sensitivity, and 7.8 FPs/scan at 80% sensitivity. (orig.)

  2. Dynamic Gd-DTPA enhanced breath-hold 1.5 t MRI of normal lungs and patients with interstitial lung disease and pulmonary nodules: preliminary results

    International Nuclear Information System (INIS)

    Semelka, R.C.; Maycher, B.; Shoenut, J.P.; Kroeker, R.; Griffin, P.; Lertzman, M.

    1992-01-01

    A FLASH technique was used, which encompassed the entire thorax in the transverse plane, before and after dynamic intravenous injection of godalinium DTPA (Gd-DTPA) to study 7 patients with normal lungs, 12 patients with interstitial lung disease (ILD), and 11 patients with pulmonary nodules. Comparative CT studies were obtained within 2 weeks of the MRI study in the patients with lung disease. Quantitative signal intensity (SI) measurements were performed. Qualitative evaluation of lung parenchyma was determined in a prospective blinded fashion, and in the normal group comparison was made with the CT images. In normal patients, SI of lung parenchyma increased by 7.7±1.3%. On precontrast images, second-order pulmonary branchings were visible while post-contrast, fifth- to sixth-order branches were apparent. In patients with ILD, interstitial changes enhanced to a variable extent, increases in SI ranging from minimal (49.9%) to substantial (308.4%). Detection of pulmonary nodules improved following contrast injection. The minimum lesion size detectable decreased from 8 mm precontrast to 5 mm post-contrast. Percentage contrast enhancement was greater for malignant nodules (124.2±79.7%) than benign nodules (5.8±4.7%) (p<0.01). (orig.)

  3. Role of digital tomosynthesis and dual energy subtraction digital radiography in detecting pulmonary nodules

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Sarvana G. [Department of Radiodiagnosis and Imaging, Postgraduate Institute of Medical Education and Research (PGIMER), Sector 12, Chandigarh 160012 (India); Garg, Mandeep Kumar, E-mail: gargmandeep01@gmail.com [Department of Radiodiagnosis and Imaging, Postgraduate Institute of Medical Education and Research (PGIMER), Sector 12, Chandigarh 160012 (India); Khandelwal, Niranjan; Gupta, Pankaj [Department of Radiodiagnosis and Imaging, Postgraduate Institute of Medical Education and Research (PGIMER), Sector 12, Chandigarh 160012 (India); Gupta, Dheeraj; Aggarwal, Ashutosh Nath [Department of Pulmonary Medicine, Postgraduate Institute of Medical Education and Research (PGIMER), Sector 12, Chandigarh 160012 (India); Bansal, Subash Chand [Department of Radiodiagnosis and Imaging, Postgraduate Institute of Medical Education and Research (PGIMER), Sector 12, Chandigarh 160012 (India)

    2015-07-15

    Highlights: • Accuracy of digital tomosynthesis for nodule detection is substantially higher. • Improvement in diagnostic accuracy is most pronounced for nodules <10 mm. • There is five times increase in radiation dose compared to DR. - Abstract: Objective: Digital tomosynthesis (DT) and dual-energy subtraction digital radiography (DES-DR) are known to perform better than conventional radiography in the detection of pulmonary nodules. Yet the comparative diagnostic performances of DT, DES-DR and digital radiography (DR) is not known. The present study compares the diagnostic performances of DT, DES-DR and DR in detecting pulmonary nodules. Subjects and methods: The institutional Review Board approved the study and informed written consent was obtained. Fifty-five patients (30 with pulmonary nodules, 25 with non-nodular focal chest pathology) were included in the study. DT and DES-DR were performed within14 days of MDCT. Composite images acquired at high kVp as part of DES-DR were used as DR images. Images were analyzed for presence of nodules and calcification in nodules. Interpretations were assigned confidence levels from 1 to 5 according to Five-Point rating scale. Areas under the receiver operating characteristic curves were compared using Z test. Results: A total of 110 (88 non-calcified, 22 calcified) nodules were identified on MDCT. For detection of nodules, DR showed cumulative sensitivity and specificity of 25.45% and 67.97%, respectively. DT showed a cumulative sensitivity and specificity of 60.9% and 85.07%, respectively. The performance was significantly better than DR (p < 0.003). DES-DR showed sensitivity and specificity of 27.75% and 82.64%, not statistically different from those of DR (p—0.92). In detection of calcification, there was no statistically significant difference between DT, DES-DR and DR. Conclusions: DT performs significantly better than DES-DR and DR at the cost of moderate increase in radiation dose.

  4. Discriminative Localization in CNNs for Weakly-Supervised Segmentation of Pulmonary Nodules.

    Science.gov (United States)

    Feng, Xinyang; Yang, Jie; Laine, Andrew F; Angelini, Elsa D

    2017-09-01

    Automated detection and segmentation of pulmonary nodules on lung computed tomography (CT) scans can facilitate early lung cancer diagnosis. Existing supervised approaches for automated nodule segmentation on CT scans require voxel-based annotations for training, which are labor- and time-consuming to obtain. In this work, we propose a weakly-supervised method that generates accurate voxel-level nodule segmentation trained with image-level labels only. By adapting a convolutional neural network (CNN) trained for image classification, our proposed method learns discriminative regions from the activation maps of convolution units at different scales, and identifies the true nodule location with a novel candidate-screening framework. Experimental results on the public LIDC-IDRI dataset demonstrate that, our weakly-supervised nodule segmentation framework achieves competitive performance compared to a fully-supervised CNN-based segmentation method.

  5. Quantitative CT: technique dependence of volume estimation on pulmonary nodules

    Science.gov (United States)

    Chen, Baiyu; Barnhart, Huiman; Richard, Samuel; Colsher, James; Amurao, Maxwell; Samei, Ehsan

    2012-03-01

    Current estimation of lung nodule size typically relies on uni- or bi-dimensional techniques. While new three-dimensional volume estimation techniques using MDCT have improved size estimation of nodules with irregular shapes, the effect of acquisition and reconstruction parameters on accuracy (bias) and precision (variance) of the new techniques has not been fully investigated. To characterize the volume estimation performance dependence on these parameters, an anthropomorphic chest phantom containing synthetic nodules was scanned and reconstructed with protocols across various acquisition and reconstruction parameters. Nodule volumes were estimated by a clinical lung analysis software package, LungVCAR. Precision and accuracy of the volume assessment were calculated across the nodules and compared between protocols via a generalized estimating equation analysis. Results showed that the precision and accuracy of nodule volume quantifications were dependent on slice thickness, with different dependences for different nodule characteristics. Other parameters including kVp, pitch, and reconstruction kernel had lower impact. Determining these technique dependences enables better volume quantification via protocol optimization and highlights the importance of consistent imaging parameters in sequential examinations.

  6. Identification of benign and malignant thyroid nodules by in vivo iodine concentration measurement using single-source dual energy CT

    Science.gov (United States)

    Gao, Shun-Yu; Zhang, Xiao-Yan; Wei, Wei; Li, Xiao-Ting; Li, Yan-Ling; Xu, Min; Sun, Ying-Shi; Zhang, Xiao-Peng

    2016-01-01

    Abstract This study proposed to determine whether in vivo iodine concentration measurement by single-source dual energy (SSDE) CT can improve differentiation between benign and malignant thyroid nodules. In total, 53 patients presenting with thyroid nodules underwent SSDE CT scanning. Iodine concentrations were measured for each nodule and normal thyroid tissue using the GSI-viewer image analysis software. A total of 26 thyroid nodules were malignant in 26 patients and confirmed by surgery; 33 nodules from 27 patients were benign, with 10 confirmed by surgery and others after follow-up. Iodine concentrations with plain CT were significantly lower in malignant than benign nodules (0.47 ± 0.20 vs 1.17 ± 0.38 mg/mL, P = 0.00). Receiver operating characteristic (ROC) curve showed an area under the curve (AUC) of 0.93; with a cutoff of 0.67, iodine concentration showed 92.3% sensitivity and 88.5% specificity in diagnosing malignancy. Iodine concentration obtained by enhanced and plain CT were significantly higher in malignant than benign nodules (9.05 ± 3.35 vs 3.46 ± 2.24 mg/mL, P = 0.00). ROC curve analysis showed an AUC of 0.93; with a cutoff value of 3.37, iodine concentration displayed 78% sensitivity, 95% specificity in diagnosing malignancy. Combining unenhanced with enhanced iodine concentrations, the diagnostic equation was: Y = –8.641 × unenhanced iodine concentration + 0.663 × iodine concentration. ROC curve showed an AUC of 0.98 (95% CI, 0.94, 1.00). With Y ≥ –2 considered malignancy, diagnostic sensitivity and specificity were 96%, 96.3%, respectively. This study concluded that SSDE CT can detect the differences in iodine uptake and blood supply between benign and malignant thyroid lesions. PMID:27684811

  7. Research on a Pulmonary Nodule Segmentation Method Combining Fast Self-Adaptive FCM and Classification

    Directory of Open Access Journals (Sweden)

    Hui Liu

    2015-01-01

    Full Text Available The key problem of computer-aided diagnosis (CAD of lung cancer is to segment pathologically changed tissues fast and accurately. As pulmonary nodules are potential manifestation of lung cancer, we propose a fast and self-adaptive pulmonary nodules segmentation method based on a combination of FCM clustering and classification learning. The enhanced spatial function considers contributions to fuzzy membership from both the grayscale similarity between central pixels and single neighboring pixels and the spatial similarity between central pixels and neighborhood and improves effectively the convergence rate and self-adaptivity of the algorithm. Experimental results show that the proposed method can achieve more accurate segmentation of vascular adhesion, pleural adhesion, and ground glass opacity (GGO pulmonary nodules than other typical algorithms.

  8. Subtle pulmonary nodules: detection and identification with storage phosphor radiographs and conventional chest films

    International Nuclear Information System (INIS)

    Scheck, R.J.; Schaetzl, M.; Kandziora, C.; Panzer, M.; Rienmueller, R.

    1994-01-01

    To determine the value of digital storagephosphor radiography (SR) on the detection and identification of subtle lung nodules, postero-anterior (PA) and lateral (LAT) film-screen (FR) chest radiographs were compared with isodose SR images of 45 patients with metastatic malignancies. The SR postprocessing was done with a particular mode previously optimized for routine chest radiography. Pulmonary metastases were found in 34 patients and were proved or excluded by CT (n=28) or longterm follow-up FR (n=17). Chest images were divided into four regions for evaluation of image quality, number of lung nodules per region and marked pulmonary structures by receiver-operating characteristics (ROC) analysis (45 patients; 125 nodules; 2810 observations; five readers). Of the nodules selected for an ROC study 82% were 0.5-1.0 cm in diameter. Overall image quality was rated better for FR concerning lung fields (PA) and mediastinum/hilum (LAT). More lung-field nodules were detected on FR than on SR chest images. Use of FR was superior to SR in the general identification of nodules (PA chest), especially concerning intermediate and subtle abnormalities, whereas there was no significant difference for LAT chest images. Our results show, that currently FR still has advantages over SR in the detection and identification of subtle lung nodules in routine clinical radiography. (orig.)

  9. Effect of radiation dose reduction and iterative reconstruction on computer-aided detection of pulmonary nodules : Intra-individual comparison

    NARCIS (Netherlands)

    Den Harder, Annemarie M.; Willemink, Martin J.; Van Hamersvelt, Robbert W.; Vonken, Evert-Jan P A; Milles, Julien; Schilham, Arnold M R; Lammers, Jan Willem; De Jong, Pim A.; Leiner, Tim; Budde, Ricardo P J

    2016-01-01

    Objective To evaluate the effect of radiation dose reduction and iterative reconstruction (IR) on the performance of computer-aided detection (CAD) for pulmonary nodules. Methods In this prospective study twenty-five patients were included who were scanned for pulmonary nodule follow-up. Image

  10. An Unusual Radiologic Manifestation of Pulmonary Tuberculosis with Bilateral Multiple Lung Nodules and Diffuse Alveolar Hemorrhage: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Seo In; Seon, Hyun Ju; Kim, Yun Hyeon [Dept. of Radiology, Chunnam National University Hospital, Gwangju (Korea, Republic of); Choi, Sung [Dept. of Radiology, Chunnam National University Hwasun Hospital, Hwasun(Korea, Republic of)

    2011-12-15

    Pulmonary tuberculosis presenting as bilateral multiple lung nodules or diffuse alveolar hemorrhage is very rare. Here, we report a case of pulmonary tuberculosis presenting as bilateral multiple lung nodules and diffuse alveolar hemorrhage mimicking granulomatous vasculitis, such as Wegener's granulomatosis.

  11. Preliminary evaluation of lung care software of 16-slice helical CT in the study of pulmonary nodules

    International Nuclear Information System (INIS)

    Song Wei; Jin Zhengyu; Yan Hongzhen; Wang Yun; Zhang Yunqing; Wang Linhui; Zhu Haifeng; Liang Jixiang; Qi Bing

    2005-01-01

    Objective: To evaluate the auxiliary diagnostic ability and applicability of the Lung Care software for the study of the pulmonary nodules. Methods: Fifty-six patients underwent low-dose CT scan with 1.5 mm collimation, 4 mm reconstruction interval, and 4 mm reconstruction slice in group A, and with 1.5 mm collimation, 2 mm reconstruction interval, and 2 mm reconstruction slice in group B. 12 patients underwent low-dose CT with 0.75 mm collimation, 0.75 mm reconstruction interval, and 0.75 mm reconstruction slice in group C. The nodules detected in groups A, B, and C were analyzed by r-MPR or VOI of the Lung Care software to distinguish the true pulmonary nodules from the vessels. The volume and density distribution of the true pulmonary nodules in groups A, B, and C were measured with the Lung Care software. Results: It was difficult to observe the diffuse pulmonary nodules by r-MPR or VOI of the Lung Care software. The images of each patient in group C were too many to be applied in the clinic. There was statistically consistent in the observation of pulmonary nodules between r-MPR and VOI, but the coincidence was not good (Kappa=0.369, P=0.002). There was statistically significant difference in showing faint nodules between r-MPR and VOI (P=0.001), r-MPR was better than VOI. There was statistically significant difference between group A and B in showing = 3.886, P=0.045), but no statistically significant difference in showing 5-10 mm nodules (χ 2 =0.170, P=0.680). The volume and density distribution of most 5 - ≤20 mm nodules were successfully measured with the Lung Care software, whereas those of most 2 =5.811, P=0.016) and 5-10 mm nodules (χ 2 =13.500, P 10 - ≤20 mm nodules (χ 2 =0.000, P=1.000). Conclusion: For distinguishing the true pulmonary nodules from others, the Lung Care software is suitable for the well-edged pulmonary nodules and most faint nodules, but not suitable for the nodules such as ground-glass opacity. For measuring the volume and

  12. CT-guided marking of pulmonary nodules with a special lung marking wire before video-assisted thoracoscopic surgery. Review of 184 cases; CT-gestuetzte Drahtmarkierung vor videoassistierter thorakoskopischer OP von pulmonalen Rundherden. Eine Auswertung von 184 Faellen

    Energy Technology Data Exchange (ETDEWEB)

    Schulze, M.K.; Eichfeld, U.; Kahn, T.; Stumpp, P. [Universitaetsklinikum Leipzig AoeR (Germany). Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie

    2012-06-15

    Purpose: Minimally invasive techniques like video-assisted thoracoscopic surgery (VATS) are currently the method of choice for the resection of small pulmonary nodules, when they are located in the periphery of the lungs. To guarantee quick and safe intraoperative identification of the nodule, preoperative marking is necessary and sensible. We report about our experiences in 184 markings with a special lung marking wire, which is placed in or around the pulmonary nodule using CT guidance. Materials and Methods: In 184 patients (97 m, 87f, mean age: 58.1 {+-} 13.7 years) with pulmonary nodules, scheduled for resection with VATS, a special lung marking wire was placed preoperatively under CT guidance. We evaluated the technical success, safety, necessity of conversion to thoracotomy and histology in all patients. Results: The marking wire could be positioned successfully in 181 cases (98.4 %). There was one major complication (uncontrollable pneumothorax). Minor adverse events like small pneumothorax (53.3 %) or a perifocal bleeding (30.4 %) did not necessitate treatment. Complete resection of the marked nodule was successful in 98.4 % of the patients. Conversion to thoracotomy was necessary in 29 patients (15.9 %) due to bleeding, adhesions, malignancy or wire dislocation. Histology revealed a benign nodule in 96 cases (54.4 %) and a malignant lesion in 78 cases (45.6 %), of which only 21 nodules (11.5 %) turned out to present a primary pulmonary carcinoma. Conclusion: CT-guided marking of pulmonary nodules using a special marking wire followed by thoracoscopic resection is an efficient and safe method for diagnosing suspicious nodules in the periphery of the lung. (orig.)

  13. Clinical Experience of the Treatment of Solitary Pulmonary Nodules with Da Vinci Surgical System

    Directory of Open Access Journals (Sweden)

    Xiangdong TONG

    2014-07-01

    Full Text Available Background and objective A solitary pulmonary nodule (SPN is defined as a round intraparenchimal lung lesion less than 3 cm in size, not associated with atelectasis or adenopathy. The aim of this study is to learn clinical experience of the treatment of SPN with Da Vinci Surgical System. Methods A total of 9 patients with solitary pulmonary nodules (SPN less than 3 cm in diameter was treated with Da Vinci Surgical System (Intuitive Surgical, California in thoracic surgery department from General Hospital of Shenyang Militrary Region from November 2011 to March 2014. This group of patients included 3 males and 6 females, and the mean age was 51±9.9 yr (range: 41-74 yr. Most of the patients were no obvious clinical symptoms (7 cases were found by physical examination, others were with cough and expectoration. Their median medical history was 12 mo (range: 4 d-3 yr. All the lesions of patients were peripheral pulmonary nodules and the mean diameter of those was (1.4±0.6 cm(range: 0.8-2.8 cm. Wedge-shaped resection or lobectomy was performed depending on the result of rapid pathology and systemic lymph node dissection was done for malignant leision. We used general anesthesis with double lumens trachea cannula. We set the patients in lateral decubitus position with jackknife. The patient cart enter from top of the patient. The position of trocars would be set according to the position of lesion. A 12 mm incision was positioned at the 8th intercostal space in the posterior axillary line as vision port, and two 8 mm incisions were positioned at the 5th intercostal space between the anterior axillary line and midclavicular line, and the 8th infrascapular line as robotic instrument ports about 10 cm apart from the vision port. One additional auxiliary small incision for instrument without retracting ribs was set at the 7th intercostal space in the middle axillary line. Results There were 4 benign leisions and 5 malignancies identified. Wedge

  14. Pulmonary nodule registration in serial CT scans based on rib anatomy and nodule template matching

    International Nuclear Information System (INIS)

    Shi Jiazheng; Sahiner, Berkman; Chan, H.-P.; Hadjiiski, Lubomir; Zhou, C.; Cascade, Philip N.; Bogot, Naama; Kazerooni, Ella A.; Wu, Y.-T.; Wei, J.

    2007-01-01

    An automated method is being developed in order to identify corresponding nodules in serial thoracic CT scans for interval change analysis. The method uses the rib centerlines as the reference for initial nodule registration. A spatially adaptive rib segmentation method first locates the regions where the ribs join the spine, which define the starting locations for rib tracking. Each rib is tracked and locally segmented by expectation-maximization. The ribs are automatically labeled, and the centerlines are estimated using skeletonization. For a given nodule in the source scan, the closest three ribs are identified. A three-dimensional (3D) rigid affine transformation guided by simplex optimization aligns the centerlines of each of the three rib pairs in the source and target CT volumes. Automatically defined control points along the centerlines of the three ribs in the source scan and the registered ribs in the target scan are used to guide an initial registration using a second 3D rigid affine transformation. A search volume of interest (VOI) is then located in the target scan. Nodule candidate locations within the search VOI are identified as regions with high Hessian responses. The initial registration is refined by searching for the maximum cross-correlation between the nodule template from the source scan and the candidate locations. The method was evaluated on 48 CT scans from 20 patients. Experienced radiologists identified 101 pairs of corresponding nodules. Three metrics were used for performance evaluation. The first metric was the Euclidean distance between the nodule centers identified by the radiologist and the computer registration, the second metric was a volume overlap measure between the nodule VOIs identified by the radiologist and the computer registration, and the third metric was the hit rate, which measures the fraction of nodules whose centroid computed by the computer registration in the target scan falls within the VOI identified by the

  15. Quantitative evaluation of contrast-enhanced ultrasound after intravenous administration of a microbubble contrast agent for differentiation of benign and malignant thyroid nodules: assessment of diagnostic accuracy.

    Science.gov (United States)

    Nemec, Ursula; Nemec, Stefan F; Novotny, Clemens; Weber, Michael; Czerny, Christian; Krestan, Christian R

    2012-06-01

    To investigate the diagnostic accuracy, through quantitative analysis, of contrast-enhanced ultrasound (CEUS), using a microbubble contrast agent, in the differentiation of thyroid nodules. This prospective study enrolled 46 patients with solitary, scintigraphically non-functional thyroid nodules. These patients were scheduled for surgery and underwent preoperative CEUS with pulse-inversion harmonic imaging after intravenous microbubble contrast medium administration. Using histology as a standard of reference, time-intensity curves of benign and malignant nodules were compared by means of peak enhancement and wash-out enhancement relative to the baseline intensity using a mixed model ANOVA. ROC analysis was performed to assess the diagnostic accuracy in the differentiation of benign and malignant nodules on CEUS. The complete CEUS data of 42 patients (31/42 [73.8%] benign and 11/42 [26.2%] malignant nodules) revealed a significant difference (P benign and malignant nodules. Furthermore, based on ROC analysis, CEUS demonstrated sensitivity of 76.9%, specificity of 84.8% and accuracy of 82.6%. Quantitative analysis of CEUS using a microbubble contrast agent allows the differentiation of benign and malignant thyroid nodules and may potentially serve, in addition to grey-scale and Doppler ultrasound, as an adjunctive tool in the assessment of patients with thyroid nodules. • Contrast-enhanced ultrasound (CEUS) helps differentiate between benign and malignant thyroid nodules. • Quantitative CEUS analysis yields sensitivity of 76.9% and specificity of 84.8%. • CEUS may be a potentially useful adjunct in assessing thyroid nodules.

  16. Detection of pulmonary nodules at paediatric CT: maximum intensity projections and axial source images are complementary

    International Nuclear Information System (INIS)

    Kilburn-Toppin, Fleur; Arthurs, Owen J.; Tasker, Angela D.; Set, Patricia A.K.

    2013-01-01

    Maximum intensity projection (MIP) images might be useful in helping to differentiate small pulmonary nodules from adjacent vessels on thoracic multidetector CT (MDCT). The aim was to evaluate the benefits of axial MIP images over axial source images for the paediatric chest in an interobserver variability study. We included 46 children with extra-pulmonary solid organ malignancy who had undergone thoracic MDCT. Three radiologists independently read 2-mm axial and 10-mm MIP image datasets, recording the number of nodules, size and location, overall time taken and confidence. There were 83 nodules (249 total reads among three readers) in 46 children (mean age 10.4 ± 4.98 years, range 0.3-15.9 years; 24 boys). Consensus read was used as the reference standard. Overall, three readers recorded significantly more nodules on MIP images (228 vs. 174; P < 0.05), improving sensitivity from 67% to 77.5% (P < 0.05) but with lower positive predictive value (96% vs. 85%, P < 0.005). MIP images took significantly less time to read (71.6 ± 43.7 s vs. 92.9 ± 48.7 s; P < 0.005) but did not improve confidence levels. Using 10-mm axial MIP images for nodule detection in the paediatric chest enhances diagnostic performance, improving sensitivity and reducing reading time when compared with conventional axial thin-slice images. Axial MIP and axial source images are complementary in thoracic nodule detection. (orig.)

  17. Does the thinking aloud condition affect the search for pulmonary nodules?

    Science.gov (United States)

    Littlefair, Stephen; Brennan, Patrick; Reed, Warren; Williams, Mark; Pietrzyk, Mariusz W.

    2012-02-01

    Aim: To measure the effect of thinking aloud on perceptual accuracy and visual search behavior during chest radiograph interpretation for pulmonary nodules. Background: Thinking Aloud (TA) is an empirical research method used by researchers in cognitive psychology and behavioural analysis. In this pilot study we wanted to examine whether TA had an effect on the perceptual accuracy and search patterns of subjects looking for pulmonary nodules on adult posterioranterior chest radiographs (PA CxR). Method: Seven academics within Medical Radiation Sciences at The University of Sydney participated in two reading sessions with and without TA. Their task was to localize pulmonary nodules on 30 PA CxR using mouse clicks and rank their confidence levels of nodule presence. Eye-tracking recordings were collected during both viewing sessions. Time to first fixation, duration of first fixation, number of fixations, cumulative time of fixation and total viewing time were analysed. In addition, ROC analysis was conducted on collected outcome using DBM methodology. Results: Time to first nodule fixation was significantly longer (p=0.001) and duration of first fixation was significantly shorter (p=0.043). No significant difference was observed in ROC AUC scores between control and TA conditions. Conclusion: Our results confirm that TA has little effect on perceptual ability or performance, except for prolonging the task. However, there were significant differences in visual search behavior. Future researchers in radio-diagnosis could use the think aloud condition rather than silence so as to more closely replicate the clinical scenario.

  18. Pulmonary nodules and masses in lung transplant recipients: clinical and CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Morla, Olivier; Liberge, Renan; Arrigoni, Pierre Paul; Frampas, Eric [Service de Radiologie Centrale, C.H.U. Hotel Dieu, Nantes (France)

    2014-09-15

    The purpose of this study was to review the clinical and CT findings of pulmonary nodules and masses in lung transplant recipients and to determine distinguishing features among the various aetiologies. This retrospective study included 106 lung transplant recipients who had a chest CT performed over a 7-year period in a single institution. Twenty-four cases of pulmonary nodules and masses were observed on CT. Among the single lesions, three (50 %) were due to infections, one (17 %) to organizing pneumonia, and two (33 %) remained of undetermined origin. Among the multiple lesions, 14 (78 %) were due to infection, three to post-transplant lymphoproliferative disorder (17 %), and one to bronchogenic carcinoma (5 %). The two main microorganisms were P. aeruginosa and Aspergillus spp. Among 12 solid nodules > 1 cm, four (33 %) were due to malignancy: three post-transplant lymphoproliferative disorders (25 %), and one bronchogenic carcinoma (8 %). Among five cavitary nodules four (80 %) were due to aspergillosis. Infection is the most frequent aetiology of pulmonary nodules and masses in lung transplant recipients, but other causes such as post-transplant lymphoproliferative disorder, bronchogenic carcinoma, or organizing pneumonia should be considered. (orig.)

  19. Detection of the Single-Session Complete Ablation Rate by Contrast-Enhanced Ultrasound during Ultrasound-Guided Laser Ablation for Benign Thyroid Nodules: A Prospective Study

    Directory of Open Access Journals (Sweden)

    Shuhua Ma

    2016-01-01

    Full Text Available This study aimed to investigate the single-session complete ablation rate of ultrasound-guided percutaneous laser ablation (LA for benign thyroid nodules. LA was performed in 90 patients with 118 benign thyroid nodules. Contrast-enhanced ultrasound (CEUS was used to evaluate complete nodule ablation one day after ablation. Thyroid nodule volumes, thyroid functions, clinical symptoms and complications were evaluated 1, 3, 6, 12, and 18 months after ablation. Results showed that all benign thyroid nodules successfully underwent LA. The single-session complete ablation rates for nodules with maximum diameters ≤2 cm, 2-3 cm and ≥3 cm were 93.4%, 70.3% and 61.1%, respectively. All nodule volumes significantly decreased than that one day after ablation (P0.05. Three patients had obvious pain during ablation; one (1.1% had recurrent laryngeal nerve injury, but the voice returned to normal within 6 months after treatment. Thus, ultrasound-guided LA can effectively inactivate benign thyroid nodules. LA is a potentially viable minimally invasive treatment that offers good cosmetic effects.

  20. Performance of computer-aided detection of pulmonary nodules in low-dose CT: comparison with double reading by nodule volume

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Yingru; Vliegenthart, Rozemarijn; Wang, Ying; Ooijen, Peter M.A. van; Oudkerk, Matthijs [University of Groningen/University Medical Center Groningen, Center for Medical Imaging - North East Netherlands, Department of Radiology, P.O. Box 30.001, Groningen (Netherlands); Bock, Geertruida H. de [University of Groningen/University Medical Center Groningen, Department of Epidemiology, P.O. Box 30.001, Groningen (Netherlands); Klaveren, Rob J. van [Lievensberg Hospital, Department of Pulmonology, P.O. Box 135, Bergen op Zoom (Netherlands); Bogoni, Luca [CAD Group, Siemens Medical Solutions USA, Inc., Malvern, PA (United States); Jong, Pim A. de; Mali, Willem P. [University of Utrecht, Department of Radiology, University Medical Center Utrecht, P.O. Box 85500, Utrecht (Netherlands)

    2012-10-15

    To evaluate performance of computer-aided detection (CAD) beyond double reading for pulmonary nodules on low-dose computed tomography (CT) by nodule volume. A total of 400 low-dose chest CT examinations were randomly selected from the NELSON lung cancer screening trial. CTs were evaluated by two independent readers and processed by CAD. A total of 1,667 findings marked by readers and/or CAD were evaluated by a consensus panel of expert chest radiologists. Performance was evaluated by calculating sensitivity of pulmonary nodule detection and number of false positives, by nodule characteristics and volume. According to the screening protocol, 90.9 % of the findings could be excluded from further evaluation, 49.2 % being small nodules (less than 50 mm{sup 3}). Excluding small nodules reduced false-positive detections by CAD from 3.7 to 1.9 per examination. Of 151 findings that needed further evaluation, 33 (21.9 %) were detected by CAD only, one of them being diagnosed as lung cancer the following year. The sensitivity of nodule detection was 78.1 % for double reading and 96.7 % for CAD. A total of 69.7 % of nodules undetected by readers were attached nodules of which 78.3 % were vessel-attached. CAD is valuable in lung cancer screening to improve sensitivity of pulmonary nodule detection beyond double reading, at a low false-positive rate when excluding small nodules. circle Computer-aided detection (CAD) has known advantages for computed tomography (CT). (orig.)

  1. Performance of computer-aided detection of pulmonary nodules in low-dose CT: comparison with double reading by nodule volume

    International Nuclear Information System (INIS)

    Zhao, Yingru; Vliegenthart, Rozemarijn; Wang, Ying; Ooijen, Peter M.A. van; Oudkerk, Matthijs; Bock, Geertruida H. de; Klaveren, Rob J. van; Bogoni, Luca; Jong, Pim A. de; Mali, Willem P.

    2012-01-01

    To evaluate performance of computer-aided detection (CAD) beyond double reading for pulmonary nodules on low-dose computed tomography (CT) by nodule volume. A total of 400 low-dose chest CT examinations were randomly selected from the NELSON lung cancer screening trial. CTs were evaluated by two independent readers and processed by CAD. A total of 1,667 findings marked by readers and/or CAD were evaluated by a consensus panel of expert chest radiologists. Performance was evaluated by calculating sensitivity of pulmonary nodule detection and number of false positives, by nodule characteristics and volume. According to the screening protocol, 90.9 % of the findings could be excluded from further evaluation, 49.2 % being small nodules (less than 50 mm 3 ). Excluding small nodules reduced false-positive detections by CAD from 3.7 to 1.9 per examination. Of 151 findings that needed further evaluation, 33 (21.9 %) were detected by CAD only, one of them being diagnosed as lung cancer the following year. The sensitivity of nodule detection was 78.1 % for double reading and 96.7 % for CAD. A total of 69.7 % of nodules undetected by readers were attached nodules of which 78.3 % were vessel-attached. CAD is valuable in lung cancer screening to improve sensitivity of pulmonary nodule detection beyond double reading, at a low false-positive rate when excluding small nodules. circle Computer-aided detection (CAD) has known advantages for computed tomography (CT). (orig.)

  2. Detectability of pulmonary nodules with electronic collimation and conventional antiscatter grid

    International Nuclear Information System (INIS)

    Plenkovich, D.; Plavsic, B.; Robinson, A.E.; Lichtenstein, R.L.

    1989-01-01

    Electronic collimation is a method for rejection of scattered radiation and veiling glare in digital radiography. Digital images of a frozen, unembalmed, human chest phantom with simulated pulmonary nodules were obtained with use of the electronic collimation technique and a conventional 10:1 antiscatter grid. Observers were asked to locate multiple nodules and to record one of three levels of confidence. For each criterion, the total number of correct responses was divided by the total number of nodules to obtain the ordinate of a point. The total number of false-positive answers generated was divided by the number of images to obtain the abscissa of the point. The analysis was repeated for each scatter rejection method and for either the lungs or the mediastinum. The electronic collimation technique has improved the detectability of nodules projected over the mediastinum

  3. Preliminary study of diagnostic workstation with different matrix size for detection of small pulmonary nodules

    International Nuclear Information System (INIS)

    Wu Jie; Wang Xuejian; Wang Bo; Tong Juan; Wei Yuqing; Shen Guiquan; Wang Limei; Cao Jun; Sui He

    2004-01-01

    Objective: To assess the influence in detecting small pulmonary nodules (SPNs) on soft-copy images displayed with different matrix sizes. Methods: Seventy-six chest compute radiographs were selected for the study. Of the 76 test images, 36 pulmonary nodules smaller than 20 mm in diameter were proven by CT, which were further divided into two groups: 1.0-2.0 cm and Z values and standard error of three kinds of view system for individual observers. Results: For 1.0-2.0 cm group, the mean A Z values were 0.7936 for DRCS with 2-fold magnification and window technique, 0.8225 for 1 K monitor with 2-fold magnification and window technique, and 0.8367 for 2 K monitor without magnification; for Z values increased slightly as the display matrix size improved, but there were no significant differences among the three sets in the detection of SPNs in the ROC analyses. Conclusion: It is acceptable to detect small pulmonary nodules of 1.0-2.0 cm in diameter on 1 K monitor and DRCS with magnification. High resolution diagnostic workstation is recommended for detecting small pulmonary nodules <1.0 cm in diameter. Reasonable equipment for the detection of subtle abnormality may result in better cost-efficacy and diagnostic accuracy

  4. The computer tomography application of LUNG CARE to detect pulmonary nodules

    International Nuclear Information System (INIS)

    Minnoso Arabi, Yaysel; Ugarte Moreno, Dayana; Jordan Gonzalez, Jose

    2011-01-01

    The pulmonary nodule multiple or unique is frequently a casual finding and it is one of lung's cancer presentation. It's known that cancer is one of the first causes of death in our country and pulmonary tumor has become in a major sanitary problem. Methods. A descriptive prospective was carried out to detect pulmonary nodules in Medical Surgical Research Center. Patients were seen in General Medicine Consultation, in the period of time between January and December 2009. An inquiry was applied to every patients and a computer tomography scan with LUNG CARE program was performed to them. LUNG CARE program is used to early diagnosis and study of pulmonary nodule (mass). The data were analyzed with statistic packet SPSS version 13.0, for Windows. The data were summarized by means of stockings, deviations standard and percent, according to the variable type. For the comparison of the detection of nodules according to technical imagenology the test Chi -square was used at a level of significance of 0,05

  5. X-ray Digital Linear Tomosynthesis Imaging for Artificial Pulmonary Nodule Detection

    Directory of Open Access Journals (Sweden)

    Tsutomu Gomi

    2011-01-01

    Full Text Available The purpose of this paper is to identify indications for volumetric X-ray digital linear tomosynthesis (DLT with single- and dual-energy subtraction techniques for artificial pulmonary nodule detection and compare X-ray DLT, X-ray digital radiography, and computed tomography.

  6. Detection and quantification of the solid component in pulmonary subsolid nodules by semiautomatic segmentation

    Energy Technology Data Exchange (ETDEWEB)

    Scholten, Ernst T. [University Medical Center, Department of Radiology, Utrecht (Netherlands); Kennemer Gasthuis, Department of Radiology, Haarlem (Netherlands); Jacobs, Colin; Riel, Sarah van [Radboud University Medical Center, Diagnostic Image Analysis Group, Nijmegen (Netherlands); Ginneken, Bram van [Radboud University Medical Center, Diagnostic Image Analysis Group, Nijmegen (Netherlands); Fraunhofer MEVIS, Bremen (Germany); Vliegenthart, Rozemarijn [University of Groningen, University Medical Center Groningen, Department of Radiology, Groningen (Netherlands); University of Groningen, University Medical Centre Groningen, Center for Medical Imaging-North East Netherlands, Groningen (Netherlands); Oudkerk, Matthijs [University of Groningen, University Medical Centre Groningen, Center for Medical Imaging-North East Netherlands, Groningen (Netherlands); Koning, Harry J. de [Erasmus Medical Center, Department of Public Health, Rotterdam (Netherlands); Horeweg, Nanda [Erasmus Medical Center, Department of Public Health, Rotterdam (Netherlands); Erasmus Medical Center, Department of Pulmonology, Rotterdam (Netherlands); Prokop, Mathias [Radboud University Medical Center, Department of Radiology, Nijmegen (Netherlands); Gietema, Hester A.; Mali, Willem P.T.M.; Jong, Pim A. de [University Medical Center, Department of Radiology, Utrecht (Netherlands)

    2014-10-07

    To determine whether semiautomatic volumetric software can differentiate part-solid from nonsolid pulmonary nodules and aid quantification of the solid component. As per reference standard, 115 nodules were differentiated into nonsolid and part-solid by two radiologists; disagreements were adjudicated by a third radiologist. The diameters of solid components were measured manually. Semiautomatic volumetric measurements were used to identify and quantify a possible solid component, using different Hounsfield unit (HU) thresholds. The measurements were compared with the reference standard and manual measurements. The reference standard detected a solid component in 86 nodules. Diagnosis of a solid component by semiautomatic software depended on the threshold chosen. A threshold of -300 HU resulted in the detection of a solid component in 75 nodules with good sensitivity (90 %) and specificity (88 %). At a threshold of -130 HU, semiautomatic measurements of the diameter of the solid component (mean 2.4 mm, SD 2.7 mm) were comparable to manual measurements at the mediastinal window setting (mean 2.3 mm, SD 2.5 mm [p = 0.63]). Semiautomatic segmentation of subsolid nodules could diagnose part-solid nodules and quantify the solid component similar to human observers. Performance depends on the attenuation segmentation thresholds. This method may prove useful in managing subsolid nodules. (orig.)

  7. CT-guided localization of small pulmonary nodules using adjacent microcoil implantation prior to video-assisted thoracoscopic surgical resection

    Energy Technology Data Exchange (ETDEWEB)

    Su, Tian-Hao; Jin, Long; He, Wen [Capital Medical University, Department of Radiology, Beijing Friendship Hospital, Beijing (China); Fan, Yue-Feng [Xiamen University, Department of Interventional Therapy, The First Affiliated Hospital, Xiamen, Fujian (China); Hu, Li-Bao [Peking University People' s Hospital, Department of Radiology, Beijing (China)

    2015-09-15

    To describe and assess the localization of small peripheral pulmonary nodules prior to video-assisted thoracoscopic surgical (VATS) resection using the implantation of microcoils. Ninety-two patients with 101 pulmonary nodules underwent computed tomography (CT)-guided implantation of microcoils proximal to each nodule. Patients were randomly assigned to undergo entire microcoil or leaving-microcoil-end implantations. The complications and efficacy of the two implantation methods were evaluated. VATS resection of lung tissue containing each pulmonary lesion and microcoil were performed in the direction of the microcoil marker. Histopathological analysis was performed for the resected pulmonary lesions. CT-guided microcoil implantation was successful in 99/101 cases, and the placement of microcoils within 1 cm of the nodules was not disruptive. There was no difference in the complications and efficacy associated with the entire implantation method (performed for 51/99 nodules) versus the leaving-microcoil-end implantation method (performed for 48/99 nodules). All nodules were successfully removed using VATS resection. Asymptomatic pneumothorax occurred in 16 patients and mild pulmonary haemorrhage occurred in nine patients. However, none of these patients required further surgical treatment. Preoperative localization of small pulmonary nodules using a refined percutaneous microcoil implantation method was found to be safe and useful prior to VATS resection. (orig.)

  8. Evaluation of computer aided volumetry for simulated small pulmonary nodules on computed tomography

    International Nuclear Information System (INIS)

    Do, Kyung Hyun; Goo, Jin Mo; Lee, Kyung Won; Im, Jung Gi; Chung, Myung Jin

    2004-01-01

    To determine the accuracy of automated computer aided volumetry for simulated small pulmonary nodules at computed tomography using various types of phantoms Three sets of synthetic nodules (small, calcified and those adjacent to vessels) were studied. The volume of the nodules in each set was already known, and using multi-slice CT, volumetric data for each nodule was acquired from the three-dimensional reconstructed image. The volume was calculated by applying three different threshold values using Rapidia software (3D-Med, Seoul, Korea). Relative errors in the measured volume of synthetic pulmonary nodules were 17.3, 2.9, and 11.5% at -200, -400, and -600 HU, respectively, and there was good correlation between true volume and measured volume at -400 HU (r=0.96, p<0.001). For calcified nodules, relative errors in measured volume were 10.9, 5.3, and 16.5% at -200, -400, and -600 HU, respectively, and there was good correlation between true volume and measured volume at -400 HU (r=1.03, p<0.001). In cases involving synthetic nodules adjacent to vessels, relative errors were 4.6, 16.3, and 31.2% at -200, -400, and -600 HU, respectively. There was good correlation between true volume and measured volume at -200 HU (r=1.1, p<0.001). Using computer-aided volumetry, the measured volumes of synthetic nodules correlated closely with their true volume. Measured volumes were the same at each threshold level, regardless of window setting

  9. Evaluation of computer aided volumetry for simulated small pulmonary nodules on computed tomography

    International Nuclear Information System (INIS)

    Goo, Jin Mo; Lee, Kyung Won; Im, Jung Gi; Do, Kyung Hyun; Chung, Myung Jin

    2004-01-01

    To determine the accuracy of automated computer aided volumetry for simulated small pulmonary nodules at computed tomography using various types of phantoms. Three sets of synthetic nodules (small, calcified and those adjacent to vessels) were studied. The volume of the nodules in each set was already known, and using multi-slice CT, volumetric data for each nodule was acquired from the three-dimensional reconstructed image. The volume was calculated by applying three different threshold values using Rapidia software (3D-Med, Seoul, Korea). Relative errors in the measured volume of synthetic pulmonary nodules were 17.3, 2.9, and 11.5% at -200, -400, and --600 HU, respectively, and there was good correlation between true volume and measured volume at -400 HU (r=0.96, p<0.001). For calcified nodules, relative errors in measured volume were 10.9, 5.3, and 16.5% at -200, -400, and -600 HU, respectively, and there was good correlation between true volume and measured volume at -400 HU (r=1.03, p<0.001). In cases involving synthetic nodules adjacent to vessels, relative errors were 4.6, 16.3, and 31.2 % at -200, -400, and -600 HU, respectively. There was good correlation between true volume and measured volume at -200 HU (r=1.1, p<0.001). Using computer-aided volumetry, the measured volumes of synthetic nodules correlated closely with their true volume. Measured volumes were the same at each threshold level, regardless of window setting

  10. Factors associated with initial incomplete ablation for benign thyroid nodules after radiofrequency ablation: First results of CEUS evaluation.

    Science.gov (United States)

    Zhao, Chong-Ke; Xu, Hui-Xiong; Lu, Feng; Sun, Li-Ping; He, Ya-Ping; Guo, Le-Hang; Li, Xiao-Long; Bo, Xiao-Wan; Yue, Wen-Wen

    2017-01-01

    To assess the factors associated with initial incomplete ablation (ICA) after radiofrequency ablation for benign thyroid nodules (BTNs). 69 BTNs (mean volume 6.35±5.66 ml, range 1.00-25.04 ml) confirmed by fine-needle aspiration cytology (FNAC) in fifty-four patients were treated with ultrasound-guided percutaneous radiofrequency ablation (RFA) and the local treatment efficacy was immediately assessed by intra-procedural contrast-enhanced ultrasound (CEUS). The RFA was performed with a bipolar electrode (CelonProSurge 150-T20, output power: 20 W). CEUS was performed with a second generation contrast agent under low acoustic power (i.e. coded phase inversion, CPI). Characteristics of clinical factors, findings on conventional gray-scale ultrasound, color-Doppler ultrasound, and CEUS were evaluated preoperatively. Factors associated with initial ICA and initial ICA patterns on CEUS were assessed. Volume reduction ratios (VRRs) of ICA nodules were compared with those with complete ablation (CA). The RFA procedures were accomplished with a mean ablation time and mean total energy deposition of 11.13±3.39 min (range, 5.38-22.13 min) and 12612±4466 J (range, 6310-26130 J) respectively. CEUS detected initial ICA in 21 of 69 (30.8%) BTNs and 16 (76.2%) of the 21 BTNs with initial ICA achieved CA after additional RFA, leading to a final CA rate of 92.8% (64/69). The factors associated with initial ICA were predominantly solid nodule, nodule close to danger triangle area, nodule close to carotid artery, and peripheral blood flow on color-Doppler ultrasound (all P 50% at the 6-month follow-up, among which 7 nodules (10.1%) had VRRs of >90%. There were significant differences in VRRs between ICA nodules and CA nodules at the 3- and 6-month follow-up (all P ultrasound. CEUS assists quick treatment response evaluation and facilitates subsequent additional RFA and final CA of the nodules. Nodules with CA achieve a better outcome in terms of VRR in comparison with

  11. Solitary pulmonary nodules: impact of functional CT on the cost-effectiveness of FDG-PET

    International Nuclear Information System (INIS)

    Miles, K.A.; Keith, C.J.; Wong, D.C.; Griffiths, M.R.

    2002-01-01

    Full text: FDG-PET has been shown to be cost-effective for the evaluation of solitary pulmonary nodules (SPNs) in Australia. This study evaluates the impact on cost-effectiveness produced by incorporating a novel CT technique, functional CT, into diagnostic algorithms for characterisation of SPNs. Four diagnostic strategies were evaluated using decision tree sensitivity analysis. The first strategy comprised patients undergoing conventional CT alone (CT). The second comprised conventional CT followed by functional CT study (FCT), when the SPN was not benign on conventional CT. The third strategy comprised conventional CT, which if positive is followed by FDG-PET (PET) and a fourth strategy where patients with a positive conventional CT undergo functional CT, which if positive also undergo FDG-PET (FCT+PET). Values for disease prevalence and diagnostic accuracy of PET, CT and functional CT were obtained from a literature review, using Australia values where available. Procedure costs were derived from the Medicare Benefits Schedule and DRG Cost Weights for Australian public hospitals. The cost per patient, accuracy and Incremental Cost-Accuracy Ratio (ICAR) were determined for each strategy. Sensitivity analysis evaluated the effect of disease prevalence on cost-effectiveness. Results: At the prevalence of malignancy reported from Australian series (54%), the FCT strategy incurs the least cost ($5560/patient), followed by the FCT+PET ($5910/patient). The FCT+PET strategy is the most cost-effective strategy with an ICAR of $12059/patient, followed by the PET strategy with an ICAR of $12300/patient. At levels of disease prevalence below 54% the above relationship for cost-effectiveness remains the same. For high levels of disease prevalence, CT or FCT are found to be more cost-effective. At typical prevalence of malignancy the cost-effectiveness of PET is enhanced by the addition of functional CT, but at high prevalence functional CT alone is most cost

  12. Novel penalised likelihood reconstruction of PET in the assessment of histologically verified small pulmonary nodules

    International Nuclear Information System (INIS)

    Teoh, Eugene J.; Gleeson, Fergus V.; McGowan, Daniel R.; Bradley, Kevin M.; Belcher, Elizabeth; Black, Edward

    2016-01-01

    Investigate the effect of a novel Bayesian penalised likelihood (BPL) reconstruction algorithm on analysis of pulmonary nodules examined with 18F-FDG PET/CT, and to determine its effect on small, sub-10-mm nodules. 18F-FDG PET/CTs performed for nodule evaluation in 104 patients (121 nodules) were retrospectively reconstructed using the new algorithm, and compared to time-of-flight ordered subset expectation maximisation (OSEM) reconstruction. Nodule and background parameters were analysed semi-quantitatively and visually. BPL compared to OSEM resulted in statistically significant increases in nodule SUV max (mean 5.3 to 8.1, p < 0.00001), signal-to-background (mean 3.6 to 5.3, p < 0.00001) and signal-to-noise (mean 24 to 41, p < 0.00001). Mean percentage increase in SUV max (%ΔSUV max ) was significantly higher in nodules ≤10 mm (n = 31, mean 73 %) compared to >10 mm (n = 90, mean 42 %) (p = 0.025). Increase in signal-to-noise was higher in nodules ≤10 mm (224 %, mean 12 to 27) compared to >10 mm (165 %, mean 28 to 46). When applying optimum SUV max thresholds for detecting malignancy, the sensitivity and accuracy increased using BPL, with the greatest improvements in nodules ≤10 mm. BPL results in a significant increase in signal-to-background and signal-to-noise compared to OSEM. When semi-quantitative analyses to diagnose malignancy are applied, higher SUV max thresholds may be warranted owing to the SUV max increase compared to OSEM. (orig.)

  13. Novel penalised likelihood reconstruction of PET in the assessment of histologically verified small pulmonary nodules

    Energy Technology Data Exchange (ETDEWEB)

    Teoh, Eugene J.; Gleeson, Fergus V. [Oxford University Hospitals NHS Trust, Department of Radiology, Churchill Hospital, Oxford (United Kingdom); University of Oxford, Department of Oncology, Oxford (United Kingdom); McGowan, Daniel R. [University of Oxford, Department of Oncology, Oxford (United Kingdom); Oxford University Hospitals NHS Trust, Radiation Physics and Protection, Churchill Hospital, Oxford (United Kingdom); Bradley, Kevin M. [Oxford University Hospitals NHS Trust, Department of Radiology, Churchill Hospital, Oxford (United Kingdom); Belcher, Elizabeth; Black, Edward [Oxford University Hospitals NHS Trust, Department of Thoracic Surgery, John Radcliffe Hospital, Oxford (United Kingdom)

    2016-02-15

    Investigate the effect of a novel Bayesian penalised likelihood (BPL) reconstruction algorithm on analysis of pulmonary nodules examined with 18F-FDG PET/CT, and to determine its effect on small, sub-10-mm nodules. 18F-FDG PET/CTs performed for nodule evaluation in 104 patients (121 nodules) were retrospectively reconstructed using the new algorithm, and compared to time-of-flight ordered subset expectation maximisation (OSEM) reconstruction. Nodule and background parameters were analysed semi-quantitatively and visually. BPL compared to OSEM resulted in statistically significant increases in nodule SUV{sub max} (mean 5.3 to 8.1, p < 0.00001), signal-to-background (mean 3.6 to 5.3, p < 0.00001) and signal-to-noise (mean 24 to 41, p < 0.00001). Mean percentage increase in SUV{sub max} (%ΔSUV{sub max}) was significantly higher in nodules ≤10 mm (n = 31, mean 73 %) compared to >10 mm (n = 90, mean 42 %) (p = 0.025). Increase in signal-to-noise was higher in nodules ≤10 mm (224 %, mean 12 to 27) compared to >10 mm (165 %, mean 28 to 46). When applying optimum SUV{sub max} thresholds for detecting malignancy, the sensitivity and accuracy increased using BPL, with the greatest improvements in nodules ≤10 mm. BPL results in a significant increase in signal-to-background and signal-to-noise compared to OSEM. When semi-quantitative analyses to diagnose malignancy are applied, higher SUV{sub max} thresholds may be warranted owing to the SUV{sub max} increase compared to OSEM. (orig.)

  14. Solitary pulmonary nodule evaluation in regions endemic for infectious diseases: Do regional variations impact the effectiveness of fluorodeoxyglucose positron emission tomography/computed tomography.

    Science.gov (United States)

    Purandare, N C; Pramesh, C S; Agarwal, J P; Agrawal, A; Shah, S; Prabhash, K; Karimundackal, G; Jiwnani, S; Tandon, S; Rangarajan, V

    2017-01-01

    Fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) has become a preferred imaging modality for the evaluation of solitary pulmonary nodule (SPN), particularly in the developed world. Since FDG can concentrate in infective/inflammatory lesions, the diagnostic utility of FDG-PET can be questioned, particularly in regions endemic for infectious decisions. To evaluate the accuracy of FDG-PET/CT in evaluation of SPNs in a population endemic for infectious disease and to assess if regional variations have an impact on its effectiveness. All patients who underwent an FDG/PET-CT with a clinico-radiological diagnosis of SPN categorized as indeterminate were included. Based on a maximum standardized uptake values (SUVmax) cut-off of 2.5, lesions were classified as benign (2.5) and compared with gold standard histopathology. The diagnostic accuracy of PET-CT to detect malignancy was calculated. On the basis of final histopathology, lesions were grouped as (a) malignant nodules (b) infective/granulomatous nodules with a specific diagnosis and (c) nonspecific inflammatory nodules. The SUVmaxbetween these groups was compared using nonparametric statistical tests. A total of 191 patients (129 males, 62 females) with a median age of 64 years (range: 36-83) were included. Totally, 144 nodules (75.3%) were malignant and 47 were benign (24.7%). Adenocarcinoma (n = 84) was the most common malignancy. Tuberculosis (n = 16) and nonspecific infections (n = 24) were the two most common benign pathologies. There was a significant overlap in the metabolic uptake of malignant (median SUVmax-11.2, range: 3.3-34.6) and tuberculous nodules (median SUVmax-10.3, range: 2.7-22.5) with no statistically difference between their SUVmaxvalues (P = 0.43). The false-positive rate was 65.2% and the false-negative rate was 5.5%. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of FDG-PET/CT for detecting malignancy were 94

  15. Multi-detector spiral CT study of the relationships between pulmonary ground-glass nodules and blood vessels

    International Nuclear Information System (INIS)

    Gao, Feng; Li, Ming; Ge, Xiaojun; Ren, Qingguo; Hua, Yanqing; Zheng, Xiangpeng; Chen, Yan; Lv, Fangzhen

    2013-01-01

    To investigate the relationships between pulmonary ground-glass nodules (GGN) and blood vessels and their diagnostic values in differentiating GGNs. Multi-detector spiral CT imaging of 108 GGNs was retrospectively reviewed. The spatial relationships between GGNs and supplying blood vessels were categorized into four types: I, vessels passing by GGNs; II, intact vessels passing through GGNs; III, distorted, dilated or tortuous vessels seen within GGNs; IV, more complicated vasculature other than described above. Relationship types were correlated to pathologic and/or clinical findings of GGNs. Of 108 GGNs, 10 were benign, 24 preinvasive nodules and 74 adenocarcinomas that were pathologically proven. Types I, II, III and IV vascular relationships were observed in 9, 58, 21 and 20 GGNs, respectively. Type II relationship was the dominating relationship for each GGN group, but significant differences were shown among them. Correlation analysis showed strong correlation between invasive adenocarcinoma and type III and IV relationships. Subgroup analysis indicated that type III was more commonly seen in IAC with comparison to type IV more likely seen in MIA. Different GGNs have different relationships with vessels. Understanding and recognising characteristic GGN-vessel relationships may help identify which GGNs are more likely to be malignant. (orig.)

  16. [Computed tomography with computer-assisted detection of pulmonary nodules in dogs and cats].

    Science.gov (United States)

    Niesterok, C; Piesnack, S; Köhler, C; Ludewig, E; Alef, M; Kiefer, I

    2015-01-01

    The aim of this study was to assess the potential benefit of computer-assisted detection (CAD) of pulmonary nodules in veterinary medicine. Therefore, the CAD rate was compared to the detection rates of two individual examiners in terms of its sensitivity and false-positive findings. We included 51 dogs and 16 cats with pulmonary nodules previously diagnosed by computed tomography. First, the number of nodules ≥ 3 mm was recorded for each patient by two independent examiners. Subsequently, each examiner used the CAD software for automated nodule detection. With the knowledge of the CAD results, a final consensus decision on the number of nodules was achieved. The software used was a commercially available CAD program. The sensitivity of examiner 1 was 89.2%, while that of examiner 2 reached 87.4%. CAD had a sensitivity of 69.4%. With CAD, the sensitivity of examiner 1 increased to 94.7% and that of examiner 2 to 90.8%. The CAD-system, which we used in our study, had a moderate sensitivity of 69.4%. Despite its severe limitations, with a high level of false-positive and false-negative results, CAD increased the examiners' sensitivity. Therefore, its supportive role in diagnostics appears to be evident.

  17. Case Experience of Radiofrequency Ablation for Benign Thyroid Nodules: From an Ex Vivo Animal Study to an Initial Ablation in Taiwan

    Directory of Open Access Journals (Sweden)

    Ming-Tsang Lee

    2016-03-01

    Full Text Available Radiofrequency ablation (RFA is a minimally invasive technique, used with ultrasound or computed tomography guidance, which can produce tissue coagulation necrosis in various kinds of tumors in the human body. In the past 10 years, numerous studies about RFA in benign thyroid nodules have been published. Reviewing these studies, we noticed that the effectiveness of ablation was higher when it was performed with the “moving-shot technique” via an internally cooled electrode. A consensus statement published from the Korean Society of Radiology also suggested the moving-shot technique as a standard ablation procedure for benign thyroid nodule ablation in Korea. In Taiwan, most symptomatic benign nodules are currently treated with surgical removal. RFA for mass lesions is primarily performed for the treatment of metastatic hepatic tumors. In our case, we have attempted to introduce RFA for benign thyroid nodules in Taiwan. Because endocrinologists in Taiwan were not familiar with this technique, we adopted a stepwise approach in learning how to perform RFA. We conducted ex vivo animal ablation exercises to gain experience in setting the radiofrequency generator for the right ablation mode and appropriate power output. The thyroid nodule volume reduction rate after 1 year of follow up was approximately 50% in this case. The most important thing we learned from this trial is that we confirmed the safety of thyroid nodule ablation. To the best of our knowledge, this is the first reported study of RFA of a thyroid nodule in Taiwan.

  18. Differentiation of benign and malignant thyroid nodules based on the proportion of sponge-like areas on ultrasonography: imaging-pathologic correlation

    Directory of Open Access Journals (Sweden)

    Jee Young Kim

    2015-10-01

    Full Text Available Purpose: The purpose of this study was to determine whether it is possible to differentiate benign from malignant thyroid nodules according to the proportion of sponge-like appearance within the nodules. Methods: A total of 201 thyroid nodules containing sponge-like appearance from 195 patients (157 women and 38 men were included this study. Each thyroid nodule was classified into one of three grades by real-time ultrasonography (US based on the areas with a sponge-like appearance within nodule: grade I had sponge-like areas occupying 75%. We evaluated whether a correlation existed between these grades and cytopathologic diagnoses. Results: Of the 201 nodules, 196 were benign and five were malignant, and according to the US classification, 101 nodules were grade I, 45 were grade II, and 55 were grade III. Of the five malignant nodules, four were grade I, and one was grade II. No statistically significant difference was found in the rate of malignancy between grade III and grades I and II, due to insufficient statistical power. A sponge-like appearance was correlated with follicles filled with colloid and cholesterol granules in benign nodules and with papillary fronds around the dilated cystic spaces in malignant nodules. Conclusion: No malignancies were found in thyroid nodules with >75% sponge-like appearance. Due to the overall low incidence of malignancy and the limited number of patients, a statistically significant difference could not be found in the prevalence of malignancy depending on the proportion of sponge-like areas within the nodule.

  19. The impact of faceplate surface characteristics on detection of pulmonary nodules

    Science.gov (United States)

    Toomey, R. J.; Ryan, J. T.; McEntee, M. F.; McNulty, J.; Evanoff, M. G.; Cuffe, F.; Yoneda, T.; Stowe, J.; Brennan, P. C.

    2009-02-01

    Introduction In order to prevent specular reflections, many monitor faceplates have features such as tiny dimples on their surface to diffuse ambient light incident on the monitor, however, this "anti-glare" surface may also diffuse the image itself. The purpose of the study was to determine whether the surface characteristics of monitor faceplates influence the detection of pulmonary nodules under low and high ambient lighting conditions. Methods and Materials Separate observer performance studies were conducted at each of two light levels (250 lux). Twelve examining radiologists with the American Board of Radiology participated in the darker condition and eleven in the brighter condition. All observers read on both smooth "glare" and dimpled "anti-glare" faceplates in a single lighting condition. A counterbalanced methodology was utilized to minimise memory effects. In each reading, observers were presented with thirty chest images in random order, of which half contained a single simulated pulmonary nodule. They were asked to give their confidence that each image did or did not contain a nodule and to mark the suspicious location. ROC analysis was applied to resultant data. Results No statistically significant differences were seen in the trapezoidal area under the ROC curve (AUC), sensitivity, specificity or average time per case at either light level for chest specialists or radiologists from other specialities. Conclusion The characteristics of the faceplate surfaces do not appear to affect detection of pulmonary nodules. Further work into other image types is being conducted.

  20. Clinical application of CT and CT-guided percutaneous transthoracic needle biopsy in patients with indeterminate pulmonary nodules

    Energy Technology Data Exchange (ETDEWEB)

    Cardoso, Luciana Vargas; Souza Júnior, Arthur Soares, E-mail: fabianonatividade@terra.com.br [Rio Preto-Ultra-X Radiological Diagnosis Institute, São José do Rio Preto, SP (Brazil)

    2014-07-15

    Objective: To investigate the clinical application of CT and CT-guided percutaneous transthoracic needle biopsy (CT-PTNB) in patients with indeterminate pulmonary nodules (IPNs). Methods: We retrospectively studied 113 patients with PNs undergoing CT and CT-PTNB. Variables such as gender, age at diagnosis, smoking status, CT findings, and CT-PTNB techniques were analyzed. Data analysis was performed with the Student's t-test for independent samples the chi-square test, and normal approximation test for comparison of two proportions. Results: Of the 113 patients studied, 68 (60.2%) were male and 78 (69%) were smokers. The diameter of malignant lesions ranged from 2.6 cm to 10.0 cm. Most of the IPNs (85%) were located in the peripheral region. The biopsied IPNs were found to be malignant in 88 patients (77.8%) and benign in 25 (22.2%). Adenocarcinoma was the most common malignant tumor, affecting older patients. The IPN diameter was significantly greater in patients with malignant PNs than in those with benign IPNs (p < 0.001). Having regular contour correlated significantly with an IPN being benign (p = 0.022), whereas spiculated IPNs and bosselated IPNs were more often malignant (in 50.7% and 28.7%, respectively). Homogeneous attenuation and necrosis were more common in patients with malignant lesions (51.9% and 26.9%, respectively). Conclusions: In our sample, CT and CT-PTNB were useful in distinguishing between malignant and benign IPNs. Advanced age and smoking were significantly associated with malignancy. Certain CT findings related to IPNs (larger diameter, spiculated borders, homogeneous attenuation, and necrosis) were associated with malignancy. (author)

  1. Pulmonary nodules in workers exposed to urban stressor

    International Nuclear Information System (INIS)

    Sancini, A.; Fioravanti, M.; Ciarrocca, M.; Palermo, P.; Fiaschetti, M.; Schifano, M.P.; Tomei, G.; Tomei, F.

    2010-01-01

    By multilayer spiral low-dose computed tomography (LD-CT) of the chest this study assesses the early detection of lung lesions on a sample of 100 traffic policemen of a big Italian city professionally exposed to urban pollutants and 100 controls non-occupationally exposed to urban pollutants matched by sex, age, length of service and cigarette smoking habit. Exposure to urban pollutants in traffic policemen was characterized using the annual average concentrations of PM 10 , NO 2 and benzene in the period 1998-2008 measured by fixed monitoring stations located in different areas of the city. A significant and increasing number of suspicious lung nodules with diameters between 5 and 10 mm was observed: in traffic policemen (including smokers and non-smokers) vs. controls (including smokers and non-smokers); in total smokers (including traffic policemen and controls) vs. total non-smokers (traffic policemen and controls); in smoker traffic policemen vs. smoker controls and vs. non-smoker traffic policemen; in non-smoker traffic policemen vs. non-smoker controls. The RR of finding cases with at least one lung nodule with diameters between 5 and 10 mm in traffic policemen (including smokers and non-smokers) compared to controls (including smokers and non-smokers) is 1.94 (CI 1.13-3.31); in total smokers vs. non-smokers the RR is 1.96 (CI 1.20-3.19). The comparison between the interaction exposure and smoking shows an increase in smoker traffic policemen than in smoker controls (RR=2.14; CI 1.02-4.52). The RR for smoker traffic policemen was higher than in non-smoker traffic policemen (RR=2.09; CI 1.19-3.66). The results of our study show that: (1) while smoker workers have a higher risk for developing solid suspicious lung nodules, the simple routinely exposure to urban pollutants is unable to produce the same kind of increased risk; (2) the interaction of smoking and exposure to urban pollutants greatly increases the risk for the development of solid suspicious lung

  2. Pulmonary nodules in workers exposed to urban stressor

    Energy Technology Data Exchange (ETDEWEB)

    Sancini, A. [University of Rome ' Sapienza' , Department of Occupational Medicine, Viale Regina Elena 336, 00161 Rome (Italy); Fioravanti, M. [University of Rome ' Sapienza' , Department of Psychiatric Science and Psychological Medicine, Piazzale Aldo Moro 5, 00185 Rome (Italy); Ciarrocca, M.; Palermo, P.; Fiaschetti, M.; Schifano, M.P. [University of Rome ' Sapienza' , Department of Occupational Medicine, Viale Regina Elena 336, 00161 Rome (Italy); Tomei, G. [University of Rome ' Sapienza' , Department of Psychiatric Science and Psychological Medicine, Piazzale Aldo Moro 5, 00185 Rome (Italy); Tomei, F., E-mail: francesco.tomei@uniroma1.it [University of Rome ' Sapienza' , Department of Occupational Medicine, Viale Regina Elena 336, 00161 Rome (Italy)

    2010-07-15

    By multilayer spiral low-dose computed tomography (LD-CT) of the chest this study assesses the early detection of lung lesions on a sample of 100 traffic policemen of a big Italian city professionally exposed to urban pollutants and 100 controls non-occupationally exposed to urban pollutants matched by sex, age, length of service and cigarette smoking habit. Exposure to urban pollutants in traffic policemen was characterized using the annual average concentrations of PM{sub 10}, NO{sub 2} and benzene in the period 1998-2008 measured by fixed monitoring stations located in different areas of the city. A significant and increasing number of suspicious lung nodules with diameters between 5 and 10 mm was observed: in traffic policemen (including smokers and non-smokers) vs. controls (including smokers and non-smokers); in total smokers (including traffic policemen and controls) vs. total non-smokers (traffic policemen and controls); in smoker traffic policemen vs. smoker controls and vs. non-smoker traffic policemen; in non-smoker traffic policemen vs. non-smoker controls. The RR of finding cases with at least one lung nodule with diameters between 5 and 10 mm in traffic policemen (including smokers and non-smokers) compared to controls (including smokers and non-smokers) is 1.94 (CI 1.13-3.31); in total smokers vs. non-smokers the RR is 1.96 (CI 1.20-3.19). The comparison between the interaction exposure and smoking shows an increase in smoker traffic policemen than in smoker controls (RR=2.14; CI 1.02-4.52). The RR for smoker traffic policemen was higher than in non-smoker traffic policemen (RR=2.09; CI 1.19-3.66). The results of our study show that: (1) while smoker workers have a higher risk for developing solid suspicious lung nodules, the simple routinely exposure to urban pollutants is unable to produce the same kind of increased risk; (2) the interaction of smoking and exposure to urban pollutants greatly increases the risk for the development of solid

  3. Uterine intravenous leiomyomatosis with intracardiac extension and pulmonary benign metastases on FDG PET/CT: A case report

    International Nuclear Information System (INIS)

    Wang, Hui Chun; Wang, Yu Bin; Chen, Xiao Hong; Cu, Lan Lan

    2016-01-01

    A 48-year-old woman presented with a 50-day history of irregular vaginal bleeding and lower abdominal pain. Ultrasound indicated an extremely large occupying lesion in the pelvic cavity that was highly suggestive of malignancy. Fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) was performed to further assess the nature of pelvic abnormality. PET/CT images demonstrated a diffusely lobulated mass ranging from cervix up to the inferior pole of kidneys with mild FDG uptake. Simultaneously, multiple nodules in bilateral lungs and a hypodense lesion in the right ventricle were shown without FDG-avidity. Based on the imaging results, the presumptive diagnosis was uterine intravenous leiomyomatosis with intracardiac extension and pulmonary benign metastases, which was subsequently confirmed by MRI and the lesion biopsy

  4. Uterine intravenous leiomyomatosis with intracardiac extension and pulmonary benign metastases on FDG PET/CT: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Hui Chun; Wang, Yu Bin; Chen, Xiao Hong; Cu, Lan Lan [PET/CT Center, Gansu Provincial Hospital, Lanzhou (China)

    2016-04-15

    A 48-year-old woman presented with a 50-day history of irregular vaginal bleeding and lower abdominal pain. Ultrasound indicated an extremely large occupying lesion in the pelvic cavity that was highly suggestive of malignancy. Fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) was performed to further assess the nature of pelvic abnormality. PET/CT images demonstrated a diffusely lobulated mass ranging from cervix up to the inferior pole of kidneys with mild FDG uptake. Simultaneously, multiple nodules in bilateral lungs and a hypodense lesion in the right ventricle were shown without FDG-avidity. Based on the imaging results, the presumptive diagnosis was uterine intravenous leiomyomatosis with intracardiac extension and pulmonary benign metastases, which was subsequently confirmed by MRI and the lesion biopsy.

  5. Effect of Clinical Experience of Chest Tomosynthesis on Detection of Pulmonary Nodules

    International Nuclear Information System (INIS)

    Zachrisson, S.; Svalkvist, A.; Maansson, L.G.; Baath, M.; Vikgren, J.; Johnsson, Aa.A.; Boijsen, M.; Flinck, A.; Kheddache, S.

    2009-01-01

    Background: The new technique chest tomosynthesis refers to the principle of collecting low-dose projections of the chest at different angles and using these projections to reconstruct section images of the chest at a radiation dose comparable to that of chest radiography. Purpose: To investigate if, for experienced thoracic radiologists, the detectability of pulmonary nodules obtained after only a short initial learning period of chest tomosynthesis improves with additional clinical experience of the new technique. Material and Methods: Two readings of the same clinical chest tomosynthesis cases, the first performed after 6 months of clinical experience and the second after an additional period of 1 year, were conducted. Three senior thoracic radiologists, with more than 20 years of experience of chest radiography, acted as observers, with the task of detecting pulmonary nodules in a jackknife free-response receiver operating characteristics (JAFROC1) study. The image material consisted of 42 patients with and 47 patients without pulmonary nodules examined with chest tomosynthesis. Multidetector computed tomography (MDCT) was used as a reference. The total number of nodules was 131. The JAFROC1 figure of merit (FOM) was used as the principal measure of detectability. Results: The difference in the observer-averaged JAFROC1 FOM of the two readings was 0.004 (95% confidence interval: -0.11, 0.12; F-statistic: 0.01 on 1 and 2.65 df; P=0.91). Thus, no significant improvement in detectability was found after the additional clinical experience of tomosynthesis. Conclusion: The study indicates that experienced thoracic radiologists already within the first months of clinical use of chest tomosynthesis are able to take advantage of the new technique in the task of detecting pulmonary nodules

  6. Cryptogenic Organizing Pneumonia With Lung Nodules Secondary to Pulmonary Manifestation of Crohn Disease

    Directory of Open Access Journals (Sweden)

    Taufiq Zaman

    2017-05-01

    Full Text Available Crohn disease is an immune-mediated inflammatory condition with gastrointestinal and extraintestinal manifestations in patients. Pulmonary involvement of Crohn disease is one manifestation. There have been case reports which have shown Crohn disease and lung nodules which were noted to be histopathological as cryptogenic organizing pneumonia (COP. In our case, a 22-year-old woman with Crohn disease was seen with complaints of chest pain and cough. Computed tomographic scan of chest showed multiple bilateral lung nodules, for which biopsy was done, which showed COP. The case study is followed by a deeper discussion of COP and the extraintestinal manifestation seen in inflammatory bowel disease.

  7. Assessing the utility of autofluorescence-based pulmonary optical endomicroscopy to predict the malignant potential of solitary pulmonary nodules in humans

    Science.gov (United States)

    Seth, Sohan; Akram, Ahsan R.; McCool, Paul; Westerfeld, Jody; Wilson, David; McLaughlin, Stephen; Dhaliwal, Kevin; Williams, Christopher K. I.

    2016-08-01

    Solitary pulmonary nodules are common, often incidental findings on chest CT scans. The investigation of pulmonary nodules is time-consuming and often leads to protracted follow-up with ongoing radiological surveillance, however, clinical calculators that assess the risk of the nodule being malignant exist to help in the stratification of patients. Furthermore recent advances in interventional pulmonology include the ability to both navigate to nodules and also to perform autofluorescence endomicroscopy. In this study we assessed the efficacy of incorporating additional information from label-free fibre-based optical endomicrosopy of the nodule on assessing risk of malignancy. Using image analysis and machine learning approaches, we find that this information does not yield any gain in predictive performance in a cohort of patients. Further advances with pulmonary endomicroscopy will require the addition of molecular tracers to improve information from this procedure.

  8. Pulmonary Nodule Management in Lung Cancer Screening: A Pictorial Review of Lung-RADS Version 1.0.

    Science.gov (United States)

    Godoy, Myrna C B; Odisio, Erika G L C; Truong, Mylene T; de Groot, Patricia M; Shroff, Girish S; Erasmus, Jeremy J

    2018-05-01

    The number of screening-detected lung nodules is expected to increase as low-dose computed tomography screening is implemented nationally. Standardized guidelines for image acquisition, interpretation, and screen-detected nodule workup are essential to ensure a high standard of medical care and that lung cancer screening is implemented safely and cost effectively. In this article, we review the current guidelines for pulmonary nodule management in the lung cancer screening setting. Copyright © 2018 Elsevier Inc. All rights reserved.

  9. The importance of risk models for management of pulmonary nodules; Die Bedeutung von Risikomodellen fuer das Management pulmonaler Rundherde

    Energy Technology Data Exchange (ETDEWEB)

    Prosch, H.; Baltzer, P. [Medizinische Universitaet Wien, Allgemeines Krankenhaus, Universitaetsklinik fuer Radiologie und Nuklearmedizin, Wien (Austria)

    2014-05-15

    Pulmonary nodules are a frequent finding in computed tomography (CT) investigations. Further diagnostic work-up of detected nodules mainly depends on the so-called pre-test probability, i.e. the probability that the nodule is malignant or benign. The pre-test probability can be calculated by combining all relevant information, such as the age and the sex of the patient, the smoking history, and history of previous malignancies, as well as the size and CT morphology of the nodule. If additional investigations are performed to further investigate the nodules, all results must be interpreted taking into account the pre-test probability and the test performance of the investigation in order to estimate the post-test probability. In cases with a low pre-test probability, a negative result from an exact test can exclude malignancies but a positive test cannot prove malignancy in such a setting. In cases with a high pre-test probability, a positive test result can be considered as proof of malignancy but a negative test result does not exclude malignancy. (orig.) [German] Pulmonale Rundherde sind ein haeufiger Befund bei CT-Untersuchungen des Thorax. Die weiterfuehrende Abklaerung der gefunden Rundherde haengt im Wesentlichen von der so genannten Vortestwahrscheinlichkeit ab, der Wahrscheinlichkeit ob der Rundherd maligne ist oder nicht. Diese Vortestwahrscheinlichkeit laesst sich durch die Kombination aller relevanten Vorinformationen wie Alter und Geschlecht des Patienten, Raucheranamnese, Tumoranamnese, Groesse und CT-Morphologie des Rundherdes genau berechnen oder intuitiv abschaetzen. Werden weiterfuehrende Untersuchungen zur Abklaerung des Rundherdes durchgefuehrt, ist das Ergebnis dieser Untersuchung, die Nachtestwahrscheinlichkeit fuer das Vorliegen von Malignitaet, in Abhaengigkeit von der Vortestwahrscheinlichkeit und der Testguete der Untersuchung zu interpretieren. Waehrend ein genauer Test im Falle niedriger Vortestwahrscheinlichkeiten Malignitaet mit

  10. Automatic detection of pulmonary nodules at spiral CT: clinical application of a computer-aided diagnosis system

    International Nuclear Information System (INIS)

    Wormanns, Dag; Fiebich, Martin; Saidi, Mustafa; Diederich, Stefan; Heindel, Walter

    2002-01-01

    The aim of this study was to evaluate a computer-aided diagnosis (CAD) workstation with automatic detection of pulmonary nodules at low-dose spiral CT in a clinical setting for early detection of lung cancer. Eighty-eight consecutive spiral-CT examinations were reported by two radiologists in consensus. All examinations were reviewed using a CAD workstation with a self-developed algorithm for automatic detection of pulmonary nodules. The algorithm is designed to detect nodules with diameters of at least 5 mm. A total of 153 nodules were detected with at least one modality (radiologists in consensus, CAD, 85 nodules with diameter <5 mm, 68 with diameter ≥5 mm). The results of automatic nodule detection were compared to nodules detected with any modality as gold standard. Computer-aided diagnosis correctly identified 26 of 59 (38%) nodules with diameters ≥5 mm detected by visual assessment by the radiologists; of these, CAD detected 44% (24 of 54) nodules without pleural contact. In addition, 12 nodules ≥5 mm were detected which were not mentioned in the radiologist's report but represented real nodules. Sensitivity for detection of nodules ≥5 mm was 85% (58 of 68) for radiologists and 38% (26 of 68) for CAD. There were 5.8±3.6 false-positive results of CAD per CT study. Computer-aided diagnosis improves detection of pulmonary nodules at spiral CT and is a valuable second opinion in a clinical setting for lung cancer screening despite of its still limited sensitivity. (orig.)

  11. Inter- and intrascanner variability of pulmonary nodule volumetry on low-dose 64-row CT : an anthropomorphic phantom study

    NARCIS (Netherlands)

    Xie, X.; Willemink, M. J.; Zhao, Y.; de Jong, P. A.; van Ooijen, P. M. A.; Oudkerk, M.; Greuter, M. J. W.; Vliegenthart, R.

    Objective: To assess inter- and intrascanner variability in volumetry of solid pulmonary nodules in an anthropomorphic thoracic phantom using low-dose CT. Methods: Five spherical solid artificial nodules [diameters 3, 5, 8, 10 and 12mm; CT density 1100 Hounsfield units (HU)] were randomly placed

  12. The effects of iodine attenuation on pulmonary nodule volumetry using novel dual-layer computed tomography reconstructions

    Energy Technology Data Exchange (ETDEWEB)

    Harder, A.M. den; Hamersvelt, R.W. van; Leiner, T.; Schilham, A.M.R.; Willemink, M.J.; Jong, P.A. de [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Bangert, F. [Sint Antonius Ziekenhuis, Department of Radiology, Nieuwegein (Netherlands); Milles, Julien [Philips Healthcare, Best (Netherlands)

    2017-12-15

    To assess the effect of iodine attenuation on pulmonary nodule volumetry using virtual non-contrast (VNC) and mono-energetic reconstructions. A consecutive series of patients who underwent a contrast-enhanced chest CT scan were included. Images were acquired on a novel dual-layer spectral CT system. Conventional reconstructions as well as VNC and mono-energetic images at different keV levels were used for nodule volumetry. Twenty-four patients with a total of 63 nodules were included. Conventional reconstructions showed a median (interquartile range) volume and diameter of 174 (87 - 253) mm{sup 3} and 6.9 (5.4 - 9.9) mm, respectively. VNC reconstructions resulted in a significant volume reduction of 5.5% (2.6 - 11.2%; p<0.001). Mono-energetic reconstructions showed a correlation between nodule attenuation and nodule volume (Spearman correlation 0.77, (0.49 - 0.94)). Lowering the keV resulted in increased volumes while higher keV levels resulted in decreased pulmonary nodule volumes compared to conventional CT. Novel dual-layer spectral CT offers the possibility to reconstruct VNC and mono-energetic images. Those reconstructions show that higher pulmonary nodule attenuation results in larger nodule volumes. This may explain the reported underestimation in nodule volume on non-contrast enhanced compared to contrast-enhanced acquisitions. (orig.)

  13. The effects of iodine attenuation on pulmonary nodule volumetry using novel dual-layer computed tomography reconstructions

    International Nuclear Information System (INIS)

    Harder, A.M. den; Hamersvelt, R.W. van; Leiner, T.; Schilham, A.M.R.; Willemink, M.J.; Jong, P.A. de; Bangert, F.; Milles, Julien

    2017-01-01

    To assess the effect of iodine attenuation on pulmonary nodule volumetry using virtual non-contrast (VNC) and mono-energetic reconstructions. A consecutive series of patients who underwent a contrast-enhanced chest CT scan were included. Images were acquired on a novel dual-layer spectral CT system. Conventional reconstructions as well as VNC and mono-energetic images at different keV levels were used for nodule volumetry. Twenty-four patients with a total of 63 nodules were included. Conventional reconstructions showed a median (interquartile range) volume and diameter of 174 (87 - 253) mm 3 and 6.9 (5.4 - 9.9) mm, respectively. VNC reconstructions resulted in a significant volume reduction of 5.5% (2.6 - 11.2%; p<0.001). Mono-energetic reconstructions showed a correlation between nodule attenuation and nodule volume (Spearman correlation 0.77, (0.49 - 0.94)). Lowering the keV resulted in increased volumes while higher keV levels resulted in decreased pulmonary nodule volumes compared to conventional CT. Novel dual-layer spectral CT offers the possibility to reconstruct VNC and mono-energetic images. Those reconstructions show that higher pulmonary nodule attenuation results in larger nodule volumes. This may explain the reported underestimation in nodule volume on non-contrast enhanced compared to contrast-enhanced acquisitions. (orig.)

  14. Role of Computer Aided Diagnosis (CAD in the detection of pulmonary nodules on 64 row multi detector computed tomography

    Directory of Open Access Journals (Sweden)

    K Prakashini

    2016-01-01

    Full Text Available Aims and Objectives: To determine the overall performance of an existing CAD algorithm with thin-section computed tomography (CT in the detection of pulmonary nodules and to evaluate detection sensitivity at a varying range of nodule density, size, and location. Materials and Methods: A cross-sectional prospective study was conducted on 20 patients with 322 suspected nodules who underwent diagnostic chest imaging using 64-row multi-detector CT. The examinations were evaluated on reconstructed images of 1.4 mm thickness and 0.7 mm interval. Detection of pulmonary nodules, initially by a radiologist of 2 years experience (RAD and later by CAD lung nodule software was assessed. Then, CAD nodule candidates were accepted or rejected accordingly. Detected nodules were classified based on their size, density, and location. The performance of the RAD and CAD system was compared with the gold standard that is true nodules confirmed by consensus of senior RAD and CAD together. The overall sensitivity and false-positive (FP rate of CAD software was calculated. Observations and Results: Of the 322 suspected nodules, 221 were classified as true nodules on the consensus of senior RAD and CAD together. Of the true nodules, the RAD detected 206 (93.2% and 202 (91.4% by the CAD. CAD and RAD together picked up more number of nodules than either CAD or RAD alone. Overall sensitivity for nodule detection with the CAD program was 91.4%, and FP detection per patient was 5.5%. The CAD showed comparatively higher sensitivity for nodules of size 4-10 mm (93.4% and nodules in hilar (100% and central (96.5% location when compared to RAD′s performance. Conclusion: CAD performance was high in detecting pulmonary nodules including the small size and low-density nodules. CAD even with relatively high FP rate, assists and improves RAD′s performance as a second reader, especially for nodules located in the central and hilar region and for small nodules by saving RADs time.

  15. Quantitative analysis of thyroid tumors vascularity: A comparison between 3-D contrast-enhanced ultrasound and 3-D Power Doppler on benign and malignant thyroid nodules.

    Science.gov (United States)

    Caresio, Cristina; Caballo, Marco; Deandrea, Maurilio; Garberoglio, Roberto; Mormile, Alberto; Rossetto, Ruth; Limone, Paolo; Molinari, Filippo

    2018-05-15

    To perform a comparative quantitative analysis of Power Doppler ultrasound (PDUS) and Contrast-Enhancement ultrasound (CEUS) for the quantification of thyroid nodules vascularity patterns, with the goal of identifying biomarkers correlated with the malignancy of the nodule with both imaging techniques. We propose a novel method to reconstruct the vascular architecture from 3-D PDUS and CEUS images of thyroid nodules, and to automatically extract seven quantitative features related to the morphology and distribution of vascular network. Features include three tortuosity metrics, the number of vascular trees and branches, the vascular volume density, and the main spatial vascularity pattern. Feature extraction was performed on 20 thyroid lesions (ten benign and ten malignant), of which we acquired both PDUS and CEUS. MANOVA (multivariate analysis of variance) was used to differentiate benign and malignant lesions based on the most significant features. The analysis of the extracted features showed a significant difference between the benign and malignant nodules for both PDUS and CEUS techniques for all the features. Furthermore, by using a linear classifier on the significant features identified by the MANOVA, benign nodules could be entirely separated from the malignant ones. Our early results confirm the correlation between the morphology and distribution of blood vessels and the malignancy of the lesion, and also show (at least for the dataset used in this study) a considerable similarity in terms of findings of PDUS and CEUS imaging for thyroid nodules diagnosis and classification. © 2018 American Association of Physicists in Medicine.

  16. Correlation coefficient based supervised locally linear embedding for pulmonary nodule recognition.

    Science.gov (United States)

    Wu, Panpan; Xia, Kewen; Yu, Hengyong

    2016-11-01

    Dimensionality reduction techniques are developed to suppress the negative effects of high dimensional feature space of lung CT images on classification performance in computer aided detection (CAD) systems for pulmonary nodule detection. An improved supervised locally linear embedding (SLLE) algorithm is proposed based on the concept of correlation coefficient. The Spearman's rank correlation coefficient is introduced to adjust the distance metric in the SLLE algorithm to ensure that more suitable neighborhood points could be identified, and thus to enhance the discriminating power of embedded data. The proposed Spearman's rank correlation coefficient based SLLE (SC(2)SLLE) is implemented and validated in our pilot CAD system using a clinical dataset collected from the publicly available lung image database consortium and image database resource initiative (LICD-IDRI). Particularly, a representative CAD system for solitary pulmonary nodule detection is designed and implemented. After a sequential medical image processing steps, 64 nodules and 140 non-nodules are extracted, and 34 representative features are calculated. The SC(2)SLLE, as well as SLLE and LLE algorithm, are applied to reduce the dimensionality. Several quantitative measurements are also used to evaluate and compare the performances. Using a 5-fold cross-validation methodology, the proposed algorithm achieves 87.65% accuracy, 79.23% sensitivity, 91.43% specificity, and 8.57% false positive rate, on average. Experimental results indicate that the proposed algorithm outperforms the original locally linear embedding and SLLE coupled with the support vector machine (SVM) classifier. Based on the preliminary results from a limited number of nodules in our dataset, this study demonstrates the great potential to improve the performance of a CAD system for nodule detection using the proposed SC(2)SLLE. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  17. Quantitative CT analysis of pulmonary pure ground-glass nodule predicts histological invasiveness

    Energy Technology Data Exchange (ETDEWEB)

    Li, Qiong, E-mail: liqiongsmmu2008@qq.com [Department of Radiology, Changzheng Hospital, Second Military Medical University, NO. 415, Fengyang Road, Shanghai 200003 (China); Fan, Li, E-mail: fanli0930@163.com [Department of Radiology, Changzheng Hospital, Second Military Medical University, NO. 415, Fengyang Road, Shanghai 200003 (China); Cao, En-Tao, E-mail: cet123cs@126.com [Department of Radiology, Suzhou Municipal Hospital (East District), No.16 West Baita Road, Suzhu, Jiangsu Province 215001 (China); Li, Qing-Chu, E-mail: Wudi327@hotmail.com [Department of Radiology, Changzheng Hospital, Second Military Medical University, NO. 415, Fengyang Road, Shanghai 200003 (China); Gu, Ya-Feng, E-mail: 2528473557@qq.com [Department of Radiology, Changzheng Hospital, Second Military Medical University, NO. 415, Fengyang Road, Shanghai 200003 (China); Liu, Shi−Yuan, E-mail: liusy1186@163.com [Department of Radiology, Changzheng Hospital, Second Military Medical University, NO. 415, Fengyang Road, Shanghai 200003 (China)

    2017-04-15

    Objective: To assess whether quantitative computed tomography (CT) can help predict histological invasiveness of pulmonary adenocarcinoma appearing as pure ground glass nodules (pGGNs). Methods: A total of 110 pulmonary pGGNs were retrospectively evaluated, and pathologically classified as pre-invasive lesions, minimally invasive adenocarcinoma (MIA) and invasive pulmonary adenocarcinoma (IPA). Maximum nodule diameters, largest cross-sectional areas, volumes, mean CT values, weights, and CT attenuation values at the 0th,2th,5th, 25th, 50th,75th, 95th, 98th and100th percentiles on histogram, as well as 2th to 98th, 5th to 95th, 25th to 75th,and 0th to 100thslopes, respectively, were compared among the three groups. Results: Of the 110 pGGNs, 50, 28, and 32 were pre-invasive lesions, MIA, and IPA, respectively. Maximum nodule diameters, largest cross-sectional areas, andmass weights were significantly larger in the IPA group than in pre-invasive lesions. The 95th, 98th, 100th percentiles, and 2th to 98th, 25th to 75th, and 0th to 100thslopes were significantly different between pre-invasive lesions and MIA or IPA. Logistic regression analysis showed that the maximum nodule diameter (OR = 1.21, 95%CI: 1.071–1.366, p < 0.01) and 100th percentile on histogram (OR = 1.02, 95%CI: 1.009–1.032, p < 0.001) independently predicted histological invasiveness. Conclusions: Quantitative analysis of CT imaging can predict histological invasiveness of pGGNs, especiallythe maximum nodule diameter and 100th percentile on CT number histogram; this can instruct the long-term follow-up and selective surgical management.

  18. [Fluctuant pulmonary nodules as presentation of a MALT lymphoma].

    Science.gov (United States)

    Dolz Aspas, R; Toyas Miazza, C; Ruiz Ruiz, F; Morales Rull, J L; Pérez Calvo, J I

    2003-11-01

    Mucosa associated lymphoid tissue (MALT) lymphomas are a group of non- Hodgkin"s lymphomas of low malignancy degree. The most frequent location is the gastrointestinal tract. Its primary pulmonary presentation is unusual and heterogeneous from point of view radiological. Woman 61 years old with antecedents of vitiligo, gastric ulcus, cirrhosis by VHC, that go into the hospital by sudden disnea, thoracic paint with pleural characterises and fever of 38.5 degrees C, Her thorax radiography and thoracic TAC showed nodes that affect to different pulmonary lobes. The cytology by PAAF confirms their malignant nature. In subsequent radiological controls it was notice the nodels took away completely and returns in different pulmonary place in each recurrence. The presentation like fluctuant pulmonary nodes is exceptional in a MALT lymphoma. It was described a higher incidence of VHC infection and tumour. The evidence of chronic hepatitis by virus C disease, and local chronic inflammatory process as well as autoimmune disorders may be considerate like a factor that contribute to MALT lymphoma.

  19. Pulmonary nodule characterization: A comparison of conventional with quantitative and visual semi-quantitative analyses using contrast enhancement maps

    International Nuclear Information System (INIS)

    Petkovska, Iva; Shah, Sumit K.; McNitt-Gray, Michael F.; Goldin, Jonathan G.; Brown, Matthew S.; Kim, Hyun J.; Brown, Kathleen; Aberle, Denise R.

    2006-01-01

    Purpose: To determine whether conventional nodule densitometry or analysis based on contrast enhancement maps of indeterminate lung nodules imaged with contrast-enhanced CT can distinguish benign from malignant lung nodules. Materials and method: Thin section, contrast-enhanced CT (baseline, and post-contrast series acquired at 45, 90,180, and 360 s) was performed on 29 patients with indeterminate lung nodules (14 benign, 15 malignant). A thoracic radiologist identified the boundary of each nodule using semi-automated contouring to form a 3D region-of-interest (ROI) on each image series. The post-contrast series having the maximum mean enhancement was then volumetrically registered to the baseline series. The two series were subtracted volumetrically and the subtracted voxels were quantized into seven color-coded bins, forming a contrast enhancement map (CEM). Conventional nodule densitometry was performed to obtain the maximum difference in mean enhancement values for each nodule from a circular ROI. Three thoracic radiologists performed visual semi-quantitative analysis of each nodule, scoring each map for: (a) magnitude and (b) heterogeneity of enhancement throughout the entire volume of the nodule on a five-point scale. Receiver operator characteristic (ROC) analysis was conducted on these features to evaluate their diagnostic efficacy. Finally, 14 quantitative texture features were calculated for each map. A statistical analysis was performed to combine the 14 texture features to a single factor. ROC analysis of the derived aggregate factor was done as an indicator of malignancy. All features were analyzed for differences between benign and malignant nodules. Results: Using 15 HU as a threshold, 93% (14/15) of malignant and 79% (11/14) of benign nodules demonstrated enhancement. The ROC curve when higher values of enhancement indicate malignancy was generated and area under the curve (AUC) was 0.76. The visually scored magnitude of enhancement was found to be

  20. Localized thin-section CT with radiomics feature extraction and machine learning to classify early-detected pulmonary nodules from lung cancer screening

    Science.gov (United States)

    Tu, Shu-Ju; Wang, Chih-Wei; Pan, Kuang-Tse; Wu, Yi-Cheng; Wu, Chen-Te

    2018-03-01

    Lung cancer screening aims to detect small pulmonary nodules and decrease the mortality rate of those affected. However, studies from large-scale clinical trials of lung cancer screening have shown that the false-positive rate is high and positive predictive value is low. To address these problems, a technical approach is greatly needed for accurate malignancy differentiation among these early-detected nodules. We studied the clinical feasibility of an additional protocol of localized thin-section CT for further assessment on recalled patients from lung cancer screening tests. Our approach of localized thin-section CT was integrated with radiomics features extraction and machine learning classification which was supervised by pathological diagnosis. Localized thin-section CT images of 122 nodules were retrospectively reviewed and 374 radiomics features were extracted. In this study, 48 nodules were benign and 74 malignant. There were nine patients with multiple nodules and four with synchronous multiple malignant nodules. Different machine learning classifiers with a stratified ten-fold cross-validation were used and repeated 100 times to evaluate classification accuracy. Of the image features extracted from the thin-section CT images, 238 (64%) were useful in differentiating between benign and malignant nodules. These useful features include CT density (p  =  0.002 518), sigma (p  =  0.002 781), uniformity (p  =  0.032 41), and entropy (p  =  0.006 685). The highest classification accuracy was 79% by the logistic classifier. The performance metrics of this logistic classification model was 0.80 for the positive predictive value, 0.36 for the false-positive rate, and 0.80 for the area under the receiver operating characteristic curve. Our approach of direct risk classification supervised by the pathological diagnosis with localized thin-section CT and radiomics feature extraction may support clinical physicians in determining

  1. A pilot study using low-dose Spectral CT and ASIR (Adaptive Statistical Iterative Reconstruction) algorithm to diagnose solitary pulmonary nodules.

    Science.gov (United States)

    Xiao, Huijuan; Liu, Yihe; Tan, Hongna; Liang, Pan; Wang, Bo; Su, Lei; Wang, Suya; Gao, Jianbo

    2015-11-17

    Lung cancer is the most common cancer which has the highest mortality rate. With the development of computed tomography (CT) techniques, the case detection rates of solitary pulmonary nodules (SPN) has constantly increased and the diagnosis accuracy of SPN has remained a hot topic in clinical and imaging diagnosis. The aim of this study was to evaluate the combination of low-dose spectral CT and ASIR (Adaptive Statistical Iterative Reconstruction) algorithm in the diagnosis of solitary pulmonary nodules (SPN). 62 patients with SPN (42 cases of benign SPN and 20 cases of malignant SPN, pathology confirmed) were scanned by spectral CT with a dual-phase contrast-enhanced method. The iodine and water concentration (IC and WC) of the lesion and the artery in the image that had the same density were measured by the GSI (Gemstone Spectral Imaging) software. The normalized iodine and water concentration (NIC and NWC) of the lesion and the normalized iodine and water concentration difference (ICD and WCD) between the arterial and venous phases (AP and VP) were also calculated. The spectral HU (Hounsfield Unit ) curve was divided into 3 sections based on the energy (40-70, 70-100 and 100-140 keV) and the slopes (λHU) in both phases were calculated. The ICAP, ICVP, WCAP and WCVP, NIC and NWC, and the λHU in benign and malignant SPN were compared by independent sample t-test. The iodine related parameters (ICAP, ICVP, NICAP, NICVP, and the ICD) of malignant SPN were significantly higher than that of benign SPN (t = 3.310, 1.330, 2.388, 1.669 and 3.251, respectively, P 0.05). The iodine related parameters and the slope of spectral curve are useful markers to distinguish the benign from the malignant lung diseases, and its application is extremely feasible in clinical applications.

  2. Subsolid pulmonary nodule morphology and associated patient characteristics in a routine clinical population

    International Nuclear Information System (INIS)

    Mets, Onno M.; Jong, Pim A. de; Scholten, Ernst T.; Chung, Kaman; Ginneken, Bram van; Schaefer-Prokop, Cornelia M.

    2017-01-01

    To determine the presence and morphology of subsolid pulmonary nodules (SSNs) in a non-screening setting and relate them to clinical and patient characteristics. A total of 16,890 reports of clinically obtained chest CT (06/2011 to 11/2014, single-centre) were searched describing an SSN. Subjects with a visually confirmed SSN and at least two thin-slice CTs were included. Nodule volumes were measured. Progression was defined as volume increase exceeding the software interscan variation. Nodule morphology, location, and patient characteristics were evaluated. Fifteen transient and 74 persistent SSNs were included (median follow-up 19.6 [8.3-36.8] months). Subjects with an SSN were slightly older than those without (62 vs. 58 years; p = 0.01), but no gender predilection was found. SSNs were mostly located in the upper lobes. Women showed significantly more often persistent lesions than men (94 % vs. 69 %; p = 0.002). Part-solid lesions were larger (1638 vs. 383 mm"3; p < 0.001) and more often progressive (68 % vs. 38 %; p = 0.02), compared to pure ground-glass nodules. Progressive SSNs were rare under the age of 50 years. Logistic regression analysis did not identify additional nodule parameters of future progression, apart from part-solid nature. This study confirms previously reported characteristics of SSNs and associated factors in a European, routine clinical population. (orig.)

  3. Subsolid pulmonary nodule morphology and associated patient characteristics in a routine clinical population

    Energy Technology Data Exchange (ETDEWEB)

    Mets, Onno M.; Jong, Pim A. de [University Medical Center Utrecht, Radiology, Utrecht (Netherlands); Scholten, Ernst T.; Chung, Kaman; Ginneken, Bram van [Radboud University Nijmegen Medical Centre, Diagnostic Imaging Analysis Group, Nijmegen (Netherlands); Schaefer-Prokop, Cornelia M. [Radboud University Nijmegen Medical Centre, Diagnostic Imaging Analysis Group, Nijmegen (Netherlands); Meander Medical Center, Radiology, Amersfoort (Netherlands)

    2017-02-15

    To determine the presence and morphology of subsolid pulmonary nodules (SSNs) in a non-screening setting and relate them to clinical and patient characteristics. A total of 16,890 reports of clinically obtained chest CT (06/2011 to 11/2014, single-centre) were searched describing an SSN. Subjects with a visually confirmed SSN and at least two thin-slice CTs were included. Nodule volumes were measured. Progression was defined as volume increase exceeding the software interscan variation. Nodule morphology, location, and patient characteristics were evaluated. Fifteen transient and 74 persistent SSNs were included (median follow-up 19.6 [8.3-36.8] months). Subjects with an SSN were slightly older than those without (62 vs. 58 years; p = 0.01), but no gender predilection was found. SSNs were mostly located in the upper lobes. Women showed significantly more often persistent lesions than men (94 % vs. 69 %; p = 0.002). Part-solid lesions were larger (1638 vs. 383 mm{sup 3}; p < 0.001) and more often progressive (68 % vs. 38 %; p = 0.02), compared to pure ground-glass nodules. Progressive SSNs were rare under the age of 50 years. Logistic regression analysis did not identify additional nodule parameters of future progression, apart from part-solid nature. This study confirms previously reported characteristics of SSNs and associated factors in a European, routine clinical population. (orig.)

  4. Accuracy of automated volumetry of pulmonary nodules across different multislice CT scanners

    International Nuclear Information System (INIS)

    Das, Marco; Muehlenbruch, Georg; Mahnken, Andreas H.; Katoh, Markus; Guenther, Rolf W.; Wildberger, Joachim E.; Ley-Zaporozhan, Julia; Kauczor, Hans-Ulrich; Gietema, H.A.; Prokop, Mathias; Czech, Andre; Diederich, Stefan; Bakai, Annemarie; Salganicoff, Marcos

    2007-01-01

    The purpose of this study was to compare the accuracy of an automated volumetry software for phantom pulmonary nodules across various 16-slice multislice spiral CT (MSCT) scanners from different vendors. A lung phantom containing five different nodule categories (intraparenchymal, around a vessel, vessel attached, pleural, and attached to the pleura), with each category comprised of 7-9 nodules (total, n = 40) of varying sizes (diameter 3-10 mm; volume 6.62 mm 3 -525 mm 3 ), was scanned with four different 16-slice MSCT scanners (Siemens, GE, Philips, Toshiba). Routine and low-dose chest protocols with thin and thick collimations were applied. The data from all scanners were used for further analysis using a dedicated prototype volumetry software. Absolute percentage volume errors (APE) were calculated and compared. The mean APE for all nodules was 8.4% (±7.7%) for data acquired with the 16-slice Siemens scanner, 14.3% (±11.1%) for the GE scanner, 9.7% (±9.6%) for the Philips scanner and 7.5% (±7.2%) for the Toshiba scanner, respectively. The lowest APEs were found within the diameter size range of 5-10 mm and volumes >66 mm 3 . Nodule volumetry is accurate with a reasonable volume error in data from different scanner vendors. This may have an important impact for intraindividual follow-up studies. (orig.)

  5. Simple localization of peripheral pulmonary nodules - CT-guided percutaneous hook-wire localization

    International Nuclear Information System (INIS)

    Poretti, F.P.; Vorwerk, D.; Brunner, E.

    2002-01-01

    Background: Video-assisted thoracoscopic surgery (VATS) is an alternative approach to small intrapulmonary nodules, if transbronchial or percutaneous biopsy have failed. We investigated the feasibility and effectiveness of the percutaneous CT-guided placement of hook-wires to localize such nodules before video-assisted thoracoscopy. Subjects and Methods: 19 patients with new by diagnosed intrapulmonary nodules underwent CT-guided hook-wire localization by application of a X-Reidy-Set (Cook, Inc., Bjaeverskov, Denmark). The average age of the patient was 63 years (range: 19-80 years), the mean distance between the nodule and the pleura visceral was 7.58 mm (range: 0-25 mm) and the mean diameter was 11.58 mm (range: 5-25 mm). After localization, the patients underwent a VATS resection of the lesion within a mean time of 30 min (range 10-48 min). Results: In all cases, resection of the nodules was successful. In 4 older patients the marking was complicated by poor cooperability. At the end of manipulation the end of the hook was distanced from the nodule. But also in these cases, resection was successfully performed. 8 patients developed an asymptomatic pneumothorax: 5 of them in a minor (max. 1.5 cm rim), three of them in a moderate (max. 3 cm rim) dimension. In 4 patients, in whom the tumor was hit directly by the needle, local bleeding occurred. In one case, haemoptoe was present. In no patient did a dislocation of the hookwire-system occur. Conclusion: CT-guided placement of a hook-wire system is a simple and reasonable procedure which facilitates safe VATS resection of small pulmonary nodules. (orig.) [de

  6. Automated detection of pulmonary nodules in CT images with support vector machines

    Science.gov (United States)

    Liu, Lu; Liu, Wanyu; Sun, Xiaoming

    2008-10-01

    Many methods have been proposed to avoid radiologists fail to diagnose small pulmonary nodules. Recently, support vector machines (SVMs) had received an increasing attention for pattern recognition. In this paper, we present a computerized system aimed at pulmonary nodules detection; it identifies the lung field, extracts a set of candidate regions with a high sensitivity ratio and then classifies candidates by the use of SVMs. The Computer Aided Diagnosis (CAD) system presented in this paper supports the diagnosis of pulmonary nodules from Computed Tomography (CT) images as inflammation, tuberculoma, granuloma..sclerosing hemangioma, and malignant tumor. Five texture feature sets were extracted for each lesion, while a genetic algorithm based feature selection method was applied to identify the most robust features. The selected feature set was fed into an ensemble of SVMs classifiers. The achieved classification performance was 100%, 92.75% and 90.23% in the training, validation and testing set, respectively. It is concluded that computerized analysis of medical images in combination with artificial intelligence can be used in clinical practice and may contribute to more efficient diagnosis.

  7. British Thoracic Society quality standards for the investigation and management of pulmonary nodules

    Science.gov (United States)

    Baldwin, David; Callister, Matthew; Akram, Ahsan; Cane, Paul; Draffan, Jeanette; Franks, Kevin; Gleeson, Fergus; Graham, Richard; Malhotra, Puneet; Pearson, Philip; Subesinghe, Manil; Waller, David; Woolhouse, Ian

    2018-01-01

    Introduction The purpose of the quality standards document is to provide healthcare professionals, commissioners, service providers and patients with a guide to standards of care that should be met for the investigation and management of pulmonary nodules in the UK, together with measurable markers of good practice. Methods Development of British Thoracic Society (BTS) Quality Standards follows the BTS process of quality standard production based on the National Institute for Health and Care Excellence process manual for the development of quality standards. Results 7 quality statements have been developed, each describing a key marker of high-quality, cost-effective care for the investigation and management of pulmonary nodules, and each statement is supported by quality measures that aim to improve the structure, process and outcomes of healthcare. Discussion BTS Quality Standards for the investigation and management of pulmonary nodules form a key part of the range of supporting materials that the Society produces to assist in the dissemination and implementation of guideline recommendations. PMID:29682290

  8. Use of Radiofrequency Ablation in Benign Thyroid Nodules: A Literature Review and Updates

    OpenAIRE

    Wong, KP; Lang, HHB

    2013-01-01

    Successful thermal ablation using radiofrequency has been reported in various tumors including liver or kidney tumors. Nonsurgical minimally invasive ablative therapy such as radiofrequency ablation (RFA) has been reported to be a safe and efficient treatment option in managing symptomatic cold thyroid nodules or hyperfunctioning thyroid nodules. Pressure and cosmetic symptoms have been shown to be significantly improved both in the short and long terms after RFA. For hyperfunctioning thyroid...

  9. Computer-aided detection of small pulmonary nodules in multidetector spiral computed tomography (MSCT) in children

    International Nuclear Information System (INIS)

    Honnef, D.; Behrendt, F.F.; Hohl, C.; Mahnken, A.H.; Guenther, R.W.; Das, M.; Mertens, R.; Stanzel, S.

    2008-01-01

    Purpose: Retrospective evaluation of computer-aided detection software (CAD) for automated detection (LungCAD, Siemens Medical solutions, Forchheim, Germany) and volumetry (LungCARE) of pulmonary nodules in dose-reduced pediatric MDCT. Materials and Methods: 30 scans of 24 children (10.4±5.9 years, 13 girls, 11 boys, 39.7±29.3 kg body weight) were performed on a 16-MDCT for tumor staging (n=18), inflammation (n=9), other indications (n=3). Tube voltage 120 kVp and effective mAs were adapted to body weight. Slice thickness 2 mm, increment 1 mm. A pediatric radiologist (U1), a CAD expert (U2) and an inexperienced radiologist (U3) independently analyzed the lung window images without and with the CAD as a second reader. In a consensus decision U1 and U2 were the reference standard. Results: Five examinations had to be excluded from the study due to other underlying lung disease. A total of 24 pulmonary nodules were found in all data sets with a minimal diameter of 0.35 mm to 3.81 mm (mean 1.7±0.85 mm). The sensitivities were as follows: U1 95.8% and 100% with CAD; U2 91.7% U3 66.7%. U2 and U3 did not detect further nodules with CAD. The sensitivity of CAD alone was 41.7% with 0.32 false-positive findings per examination. Interobserver agreement between U1/U2 regarding nodule detection with CAD was good (k=0.6500) and without CAD very good (k=0.8727). For the rest (U1/U3; U2/U3 with and without CAD), it was weak (k=0.0667-0.1884). Depending on the measured value (axial measurement, volume), there is a significant correlation (p=0.0026-0.0432) between nodule size and CAD detection. Undetected pulmonary nodules (mean 1.35 mm; range 0.35-2.61 mm) were smaller than the detected ones (mean 2.19 mm; range 1.35-3.81 mm). No significant correlation was found between CAD findings and patient age (p=0.9263) and body weight (p=0.9271) as well as nodule location (subpleural, intraparenchymal; p=1.0) and noise/SNR. (orig.)

  10. Observer Variability and the Performance between Faculties and Residents: US Criteria for Benign and Malignant Thyroid Nodules

    International Nuclear Information System (INIS)

    Kim, Sung Hun; Park, Chang Suk; Jung, So Lyung

    2010-01-01

    To evaluate the interobserver variability and performance in the interpretation of ultrasonographic (US) findings of thyroid nodules. 72 malignant nodules and 61 benign nodules were enrolled as part of this study. Five faculty radiologists and four residents independently performed a retrospective analysis of the US images. The observers received one training session after the first interpretation and then performed a secondary interpretation. Agreement was analyzed by Cohen's kappa statistic. Degree of performance was analyzed using receiver operating characteristic (ROC) curves. Agreement between the faculties was fair-to-good for all criteria; however, between residents, agreement was poor-to-fair. The area under the ROC curves was 0.72, 0.62, and 0.60 for the faculties, senior residents, and junior residents, respectively. There was a significant difference in performance between the faculties and the residents (p < 0.05). There was a significant increase in the agreement for some criteria in the faculties and the senior residents after the training session, but no significant increase in the junior residents. Independent reporting of thyroid US performed by residents is undesirable. A continuous and specialized resident training is essential to enhance the degree of agreement and performance

  11. Effect of radiation dose level on the detectability of pulmonary nodules in chest tomosynthesis.

    Science.gov (United States)

    Asplund, Sara A; Johnsson, Åse A; Vikgren, Jenny; Svalkvist, Angelica; Flinck, Agneta; Boijsen, Marianne; Fisichella, Valeria A; Månsson, Lars Gunnar; Båth, Magnus

    2014-07-01

    To investigate the detectability of pulmonary nodules in chest tomosynthesis at reduced radiation dose levels. Eighty-six patients were included in the study and were examined with tomosynthesis and computed tomography (CT). Artificial noise was added to simulate that the tomosynthesis images were acquired at dose levels corresponding to 12, 32, and 70% of the default setting effective dose (0.12 mSv). Three observers (with >20, >20 and three years of experience) read the tomosynthesis cases for presence of nodules in a free-response receiver operating characteristics (FROC) study. CT served as reference. Differences between dose levels were calculated using the jack-knife alternative FROC (JAFROC) figure of merit (FOM). The JAFROC FOM was 0.45, 0.54, 0.55, and 0.54 for the 12, 32, 70, and 100% dose levels, respectively. The differences in FOM between the 12% dose level and the 32, 70, and 100% dose levels were 0.087 (p = 0.006), 0.099 (p = 0.003), and 0.093 (p = 0.004), respectively. Between higher dose levels, no significant differences were found. A substantial reduction from the default setting dose in chest tomosynthesis may be possible. In the present study, no statistically significant difference in detectability of pulmonary nodules was found when reducing the radiation dose to 32%. • A substantial radiation dose reduction in chest tomosynthesis may be possible. • Pulmonary nodule detectability remained unchanged at 32% of the effective dose. • Tomosynthesis might be performed at the dose of a lateral chest radiograph.

  12. Intralesional saline injection for effective ultrasound-guided aspiration of benign viscous cystic thyroid nodules

    International Nuclear Information System (INIS)

    Ko, Eun Sook; Shin, Jung Hee; Sung, Jin Yong

    2014-01-01

    We aimed to evaluate the efficacy and safety of vigorous saline injection for viscous cystic thyroid nodules. Eighteen patients who underwent ultrasound-guided aspiration for viscous cystic thyroid nodules using a saline injection were included in our study. After failing to aspirate the cyst by the usual method, we vigorously injected saline into the cyst in multiple directions to break up and liquefy the viscous cystic contents to enable aspiration. The initial and the residual volume of the nodule were calculated, and the volume reduction rate and the time taken to perform the aspiration were recorded. The mean volume of the cystic nodules before aspiration was 11.0 mL (range, 1.2 to 26.0 mL), while the postaspiration volume was 4.2 mL (range, 0.2 to 14.5 mL). The mean aspirated volume was 63.7% of the initial volume. The mean procedure time was 12.4 minutes (range, 5 to 26 minutes). There were no significant complications related to the procedure. A vigorous saline injection followed by aspiration can be a useful method to aspirate viscous cystic thyroid nodules as a prestep for further intervention or simple management.

  13. Use of radiofrequency ablation in benign thyroid nodules: a literature review and updates.

    Science.gov (United States)

    Wong, Kai-Pun; Lang, Brian Hung-Hin

    2013-01-01

    Successful thermal ablation using radiofrequency has been reported in various tumors including liver or kidney tumors. Nonsurgical minimally invasive ablative therapy such as radiofrequency ablation (RFA) has been reported to be a safe and efficient treatment option in managing symptomatic cold thyroid nodules or hyperfunctioning thyroid nodules. Pressure and cosmetic symptoms have been shown to be significantly improved both in the short and long terms after RFA. For hyperfunctioning thyroid nodules, RFA is indicated for whom surgery or radioiodine are not indicated or ineffective or for those who refuse surgery or radio-iodine. Improvement of thyroid function with decreased need for antithyroid medications has been reported. Complication rate is relatively low. By reviewing the current literature, we reported its efficacy and complications and compared the efficacy of RFA relative to other ablative options such as ethanol ablation and laser ablation.

  14. Use of Radiofrequency Ablation in Benign Thyroid Nodules: A Literature Review and Updates

    Directory of Open Access Journals (Sweden)

    Kai-Pun Wong

    2013-01-01

    Full Text Available Successful thermal ablation using radiofrequency has been reported in various tumors including liver or kidney tumors. Nonsurgical minimally invasive ablative therapy such as radiofrequency ablation (RFA has been reported to be a safe and efficient treatment option in managing symptomatic cold thyroid nodules or hyperfunctioning thyroid nodules. Pressure and cosmetic symptoms have been shown to be significantly improved both in the short and long terms after RFA. For hyperfunctioning thyroid nodules, RFA is indicated for whom surgery or radioiodine are not indicated or ineffective or for those who refuse surgery or radio-iodine. Improvement of thyroid function with decreased need for antithyroid medications has been reported. Complication rate is relatively low. By reviewing the current literature, we reported its efficacy and complications and compared the efficacy of RFA relative to other ablative options such as ethanol ablation and laser ablation.

  15. Intralesional saline injection for effective ultrasound-guided aspiration of benign viscous cystic thyroid nodules

    Directory of Open Access Journals (Sweden)

    Eun Sook Ko

    2014-04-01

    Results: The mean volume of the cystic nodules before aspiration was 11.0 mL (range, 1.2 to 26.0 mL, while the postaspiration volume was 4.2 mL (range, 0.2 to 14.5 mL. The mean aspirated volume was 63.7% of the initial volume. The mean procedure time was 12.4 minutes (range, 5 to 26 minutes. There were no significant complications related to the procedure. Conclusion: A vigorous saline injection followed by aspiration can be a useful method to aspirate viscous cystic thyroid nodules as a prestep for further intervention or simple management..

  16. Effect of radiation dose level on the detectability of pulmonary nodules in chest tomosynthesis

    Energy Technology Data Exchange (ETDEWEB)

    Asplund, Sara A.; Svalkvist, Angelica; Maansson, Lars Gunnar; Baath, Magnus [University of Gothenburg, Department of Radiation Physics, Institute of Clinical Sciences, Sahlgrenska Academy, Gothenburg (Sweden); Sahlgrenska University Hospital, Department of Medical Physics and Biomedical Engineering, Gothenburg (Sweden); Johnsson, Aase A.; Vikgren, Jenny; Flinck, Agneta; Boijsen, Marianne; Fisichella, Valeria A. [University of Gothenburg, Department of Radiology, Institute of Clinical Sciences, Sahlgrenska Academy, Gothenburg (Sweden); Sahlgrenska University Hospital, Department of Radiology, Gothenburg (Sweden)

    2014-07-15

    To investigate the detectability of pulmonary nodules in chest tomosynthesis at reduced radiation dose levels. Eighty-six patients were included in the study and were examined with tomosynthesis and computed tomography (CT). Artificial noise was added to simulate that the tomosynthesis images were acquired at dose levels corresponding to 12, 32, and 70 % of the default setting effective dose (0.12 mSv). Three observers (with >20, >20 and three years of experience) read the tomosynthesis cases for presence of nodules in a free-response receiver operating characteristics (FROC) study. CT served as reference. Differences between dose levels were calculated using the jack-knife alternative FROC (JAFROC) figure of merit (FOM). The JAFROC FOM was 0.45, 0.54, 0.55, and 0.54 for the 12, 32, 70, and 100 % dose levels, respectively. The differences in FOM between the 12 % dose level and the 32, 70, and 100 % dose levels were 0.087 (p = 0.006), 0.099 (p = 0.003), and 0.093 (p = 0.004), respectively. Between higher dose levels, no significant differences were found. A substantial reduction from the default setting dose in chest tomosynthesis may be possible. In the present study, no statistically significant difference in detectability of pulmonary nodules was found when reducing the radiation dose to 32 %. (orig.)

  17. Effect of radiation dose level on the detectability of pulmonary nodules in chest tomosynthesis

    International Nuclear Information System (INIS)

    Asplund, Sara A.; Svalkvist, Angelica; Maansson, Lars Gunnar; Baath, Magnus; Johnsson, Aase A.; Vikgren, Jenny; Flinck, Agneta; Boijsen, Marianne; Fisichella, Valeria A.

    2014-01-01

    To investigate the detectability of pulmonary nodules in chest tomosynthesis at reduced radiation dose levels. Eighty-six patients were included in the study and were examined with tomosynthesis and computed tomography (CT). Artificial noise was added to simulate that the tomosynthesis images were acquired at dose levels corresponding to 12, 32, and 70 % of the default setting effective dose (0.12 mSv). Three observers (with >20, >20 and three years of experience) read the tomosynthesis cases for presence of nodules in a free-response receiver operating characteristics (FROC) study. CT served as reference. Differences between dose levels were calculated using the jack-knife alternative FROC (JAFROC) figure of merit (FOM). The JAFROC FOM was 0.45, 0.54, 0.55, and 0.54 for the 12, 32, 70, and 100 % dose levels, respectively. The differences in FOM between the 12 % dose level and the 32, 70, and 100 % dose levels were 0.087 (p = 0.006), 0.099 (p = 0.003), and 0.093 (p = 0.004), respectively. Between higher dose levels, no significant differences were found. A substantial reduction from the default setting dose in chest tomosynthesis may be possible. In the present study, no statistically significant difference in detectability of pulmonary nodules was found when reducing the radiation dose to 32 %. (orig.)

  18. A deep 3D residual CNN for false-positive reduction in pulmonary nodule detection.

    Science.gov (United States)

    Jin, Hongsheng; Li, Zongyao; Tong, Ruofeng; Lin, Lanfen

    2018-05-01

    The automatic detection of pulmonary nodules using CT scans improves the efficiency of lung cancer diagnosis, and false-positive reduction plays a significant role in the detection. In this paper, we focus on the false-positive reduction task and propose an effective method for this task. We construct a deep 3D residual CNN (convolution neural network) to reduce false-positive nodules from candidate nodules. The proposed network is much deeper than the traditional 3D CNNs used in medical image processing. Specifically, in the network, we design a spatial pooling and cropping (SPC) layer to extract multilevel contextual information of CT data. Moreover, we employ an online hard sample selection strategy in the training process to make the network better fit hard samples (e.g., nodules with irregular shapes). Our method is evaluated on 888 CT scans from the dataset of the LUNA16 Challenge. The free-response receiver operating characteristic (FROC) curve shows that the proposed method achieves a high detection performance. Our experiments confirm that our method is robust and that the SPC layer helps increase the prediction accuracy. Additionally, the proposed method can easily be extended to other 3D object detection tasks in medical image processing. © 2018 American Association of Physicists in Medicine.

  19. Quantitative Shear Wave Velocity Measurement on Acoustic Radiation Force Impulse Elastography for Differential Diagnosis between Benign and Malignant Thyroid Nodules: A Meta-analysis.

    Science.gov (United States)

    Liu, Bo-Ji; Li, Dan-Dan; Xu, Hui-Xiong; Guo, Le-Hang; Zhang, Yi-Feng; Xu, Jun-Mei; Liu, Chang; Liu, Lin-Na; Li, Xiao-Long; Xu, Xiao-Hong; Qu, Shen; Xing, Mingzhao

    2015-12-01

    The aim of this study was to evaluate the diagnostic performance of quantitative shear wave velocity (SWV) measurement on acoustic radiation force impulse (ARFI) elastography for differentiation between benign and malignant thyroid nodules using meta-analysis. The databases of PubMed and the Web of Science were searched. Studies published in English on assessment of the sensitivity and specificity of ARFI elastography for the differentiation of thyroid nodules were collected. The quantitative measurement of ARFI elastography was evaluated by SWV (m/s). Meta-Disc Version 1.4 software was used to describe and calculate the sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio and summary receiver operating characteristic curves. We analyzed a total of 13 studies, which included 1,854 thyroid nodules (including 1,339 benign nodules and 515 malignant nodules) from 1,641 patients. The summary sensitivity and specificity for differential diagnosis between benign and malignant thyroid nodules by SWV were 0.81 (95% confidence interval [CI]: 0.77-0.84) and 0.84 (95% CI: 0.81-0.86), respectively. The pooled positive and negative likelihood ratios were 5.21 (95% CI: 3.56-7.62) and 0.23 (95% CI: 0.17-0.32), respectively. The pooled diagnostic odds ratio was 27.53 (95% CI: 14.58-52.01), and the area under the summary receiver operating characteristic curve was 0.91 (Q* = 0.84). In conclusion, SWV measurement on ARFI elastography has high sensitivity and specificity for differential diagnosis between benign and malignant thyroid nodules and can be used in combination with conventional ultrasound. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  20. Solitary extramedullary plasmacytomas of thyroid in Hashimoto's thyroiditis: Mimicking benign cystic nodule on ultrasonography

    International Nuclear Information System (INIS)

    Kwon, Yohan; Kim, Soo Jin; Hur, Joon Ho; Park, Sung Hee; Lee, Sun Jin; Lee, Tae Jin

    2013-01-01

    Solitary extramedullary plasmacytoma (SEP) of the thyroid is uncommon and mostly occur in patients with a Hashimoto's thyroiditis (82%). We present a case on SEP of thyroid in Hashimoto's thyroiditis, which mimics growing benign cystic masses on serial ultrasonography.

  1. High resolution computed tomography(HRCT) findings of a solitary pulmonary nodule : differential diagnosis of cancer and tuberculosis

    International Nuclear Information System (INIS)

    Kim, Hee Soo; Choe, Kyu Ok

    1996-01-01

    To evaluate the role of HRCT in the differentiation of Pulmonary tuberculosis and lung cancer, where the manifestation of disease is a solitary pulmonary nodule(SPN). Forty eight SPNs including 29 cancers proven by surgery(n=10), by bronchoscopic biopsy(n=7) and by fine needle aspiration biopsy(n=12), and 19 tuberculous nodules proven by surgery(n=4), by bronchoscopic biopsy(n=4), by fine needle aspiration biopsy(n=5), by a positive result in AFB culture without evidence of malignant cells(n=3), and by a decrease in size on serial plain chests despite negative AFB culture(n=3) were included. Scanning parameters for HRCT were 140 KVp, 170 mA, 1.5 mm collimation, 3 sec scanning time, and a high spatial frequency algorithm was used. With regard to the marginal features of nodules, the findings more commonly observed in malignant nodules were greater average length of the longest spicule(5.35 ± 3.19 mm versus 2.75 ± 1.56 mm), and more commonspiculated nodules greater than 3 cm in diameter, 16(55%) versus 2(10.5%)(p<0.05). Regarding the internal characteristics of nodules and perinodular parenchymal changes, the findings more commonly observed in cases of cancer were air-bronchograms within nodules(14 ; 48.3%) and interlobar fissure puckering (6 ; 20.7%), whereas in tuberculosis cases the most common findings were low density of nodule(16 ; 84.2%), cavitation(12 ; 63.1%), and perinodular focal lung hypodensity(5 ; 26.3%), (p<0.05). no statstically significant difference was observed between the incidence of satellite lesion of tuberculous(73.7%) and of malignant nodules(34.5%). However, perilobular nodules or bronchovascular bundle thickening s were more commonly observed in the satellite lesions of malignant nodules(9 ; 90%), whereas centrilobular nodules or lobular consolidation were more commonly observed in those of tuberculous nodules(12 ; 85.7%), (p<0.05). HRCT provides detailed information concerning perinodular parenchymal changes and characteristics of

  2. Solitary pulmonary nodule: radiologic features and diagnostic approach; Nodulo pulmonar solitario: caracteristicas radiologicas y abordaje diagnostico

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Cambronero, Luis Enrique

    2012-07-01

    A literature review is conducted on the solitary pulmonary nodule, to determine the diagnostic methods and specific characteristics. The diagnostic methods used have been: chest radiography, computed tomography, positron emission tomography and magnetic resonance imaging. The radiological features are defined: location, size, definition of contours or edges (margins), densitometric and attenuation characteristics, cavitation, air bronchogram, growth, doubling time, satellite nodules, nutrient vessels [Spanish] Una revision bibliografica es realizada sobre el nodulo pulmonar solitario, para determinar los metodos de diagnostico y caracteristicas especificas. Los metodos de diagnostico utilizados han sido: la radiografia de torax, tomografia computarizada, tomografia por emision de positrones y resonancia magnetica. Las caracteristicas radiologicas son definidas: localizacion, tamano, definicion de los bordes o contornos (margenes), caracteristicas densitometricas y de atenuacion, cavitacion, broncograma aereo, crecimiento, tiempo de duplicacion, nodulos satelite, vasos nutrientes.

  3. Computer-aided pulmonary nodule detection. Performance of two CAD systems at different CT dose levels

    International Nuclear Information System (INIS)

    Hein, Patrick Alexander; Rogalla, P.; Klessen, C.; Lembcke, A.; Romano, V.C.

    2009-01-01

    Purpose: To evaluate the impact of dose reduction on the performance of computer-aided lung nodule detection systems (CAD) of two manufacturers by comparing respective CAD results on ultra-low-dose computed tomography (ULD-CT) and standard dose CT (SD-CT). Materials and Methods: Multi-slice computed tomography (MSCT) data sets of 26 patients (13 male and 13 female, patients 31 - 74 years old) were retrospectively selected for CAD analysis. Indication for CT examination was staging of a known primary malignancy or suspected pulmonary malignancy. CT images were consecutively acquired at 5 mAs (ULD-CT) and 75 mAs (SD-CT) with 120kV tube voltage (1 mm slice thickness). The standard of reference was determined by three experienced readers in consensus. CAD reading algorithms (pre-commercial CAD system, Philips, Netherlands: CAD-1; LungCARE, Siemens, Germany: CAD-2) were applied to the CT data sets. Results: Consensus reading identified 253 nodules on SD-CT and ULD-CT. Nodules ranged in diameter between 2 and 41 mm (mean diameter 4.8 mm). Detection rates were recorded with 72% and 62% (CAD-1 vs. CAD-2) for SD-CT and with 73% and 56% for ULD-CT. Median also positive rates per patient were calculated with 6 and 5 (CAD-1 vs. CAD-2) for SD-CT and with 8 and 3 for ULD-CT. After separate statistical analysis of nodules with diameters of 5 mm and greater, the detection rates increased to 83% and 61% for SD-CT and to 89% and 67% for ULD-CT (CAD-1 vs. CAD-2). For both CAD systems there were no significant differences between the detection rates for standard and ultra-low-dose data sets (p>0.05). Conclusion: Dose reduction of the underlying CT scan did not significantly influence nodule detection performance of the tested CAD systems. (orig.)

  4. Vessel suppressed chest Computed Tomography for semi-automated volumetric measurements of solid pulmonary nodules.

    Science.gov (United States)

    Milanese, Gianluca; Eberhard, Matthias; Martini, Katharina; Vittoria De Martini, Ilaria; Frauenfelder, Thomas

    2018-04-01

    To evaluate whether vessel-suppressed computed tomography (VSCT) can be reliably used for semi-automated volumetric measurements of solid pulmonary nodules, as compared to standard CT (SCT) MATERIAL AND METHODS: Ninety-three SCT were elaborated by dedicated software (ClearRead CT, Riverain Technologies, Miamisburg, OH, USA), that allows subtracting vessels from lung parenchyma. Semi-automated volumetric measurements of 65 solid nodules were compared between SCT and VSCT. The measurements were repeated by two readers. For each solid nodule, volume measured on SCT by Reader 1 and Reader 2 was averaged and the average volume between readers acted as standard of reference value. Concordance between measurements was assessed using Lin's Concordance Correlation Coefficient (CCC). Limits of agreement (LoA) between readers and CT datasets were evaluated. Standard of reference nodule volume ranged from 13 to 366 mm 3 . The mean overestimation between readers was 3 mm 3 and 2.9 mm 3 on SCT and VSCT, respectively. Semi-automated volumetric measurements on VSCT showed substantial agreement with the standard of reference (Lin's CCC = 0.990 for Reader 1; 0.985 for Reader 2). The upper and lower LoA between readers' measurements were (16.3, -22.4 mm 3 ) and (15.5, -21.4 mm 3 ) for SCT and VSCT, respectively. VSCT datasets are feasible for the measurements of solid nodules, showing an almost perfect concordance between readers and with measurements on SCT. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Benign Metastatic Leiomyoma Presenting as a Hemothorax

    Directory of Open Access Journals (Sweden)

    Anna M. Ponea

    2013-01-01

    Full Text Available Uterine leiomyomas have been reported to metastasize to various organs including the lungs, skeletal muscles, bone marrow, peritoneum, and heart. They may present with symptoms related to the metastases several years after hysterectomy. These tumors regress after menopause, and it is rare to detect active tumors in postmenopausal women. Despite their ability to metastasize, they are considered to be benign due to the lack of anaplasia. Pulmonary benign metastasizing leiomyoma is usually detected in the form of pulmonary nodules incidentally on imaging. Tissue biopsy of these nodules is required to identify them as benign metastasizing leiomyomas. Immunohistochemical analysis and molecular profiling may further help detect any malignant transformation in it. Untreated pulmonary benign metastasizing leiomyoma may result in the formation of cystic structures, destruction of lung parenchyma, and hemothorax and may cause respiratory failure. Surgical resection and hormonal therapy help prevent progression of this disease and provide an avenue for a cure.

  6. Diagnostic potential of real-time elastography (RTE) and shear wave elastography (SWE) to differentiate benign and malignant thyroid nodules: A systematic review and meta-analysis.

    Science.gov (United States)

    Hu, Xiangdong; Liu, Yujiang; Qian, Linxue

    2017-10-01

    Real-time elastography (RTE) and shear wave elastography (SWE) are noninvasive and easily available imaging techniques that measure the tissue strain, and it has been reported that the sensitivity and the specificity of elastography were better in differentiating between benign and malignant thyroid nodules than conventional technologies. Relevant articles were searched in multiple databases; the comparison of elasticity index (EI) was conducted with the Review Manager 5.0. Forest plots of the sensitivity and specificity and SROC curve of RTE and SWE were performed with STATA 10.0 software. In addition, sensitivity analysis and bias analysis of the studies were conducted to examine the quality of articles; and to estimate possible publication bias, funnel plot was used and the Egger test was conducted. Finally 22 articles which eventually satisfied the inclusion criteria were included in this study. After eliminating the inefficient, benign and malignant nodules were 2106 and 613, respectively. The meta-analysis suggested that the difference of EI between benign and malignant nodules was statistically significant (SMD = 2.11, 95% CI [1.67, 2.55], P benign and malignant thyroid nodules.

  7. MRI for solitary pulmonary nodule and mass assessment: Current state of the art.

    Science.gov (United States)

    Ohno, Yoshiharu; Kauczor, Hans-Ulrich; Hatabu, Hiroto; Seo, Joon Beom; van Beek, Edwin J R

    2018-03-23

    Since the clinical introduction of magnetic resonance imaging (MRI), the chest has been one of its most challenging applications, and many physicists and radiologists have tried since the 1980s to use MR for assessment of different lung diseases as well as mediastinal and pleural diseases. Since then, however, technical advances in sequencing, scanners, and coils, adaptation of parallel imaging techniques, utilization of contrast media, and development of postprocessing tools have been reported by many basic and clinical researchers. As a result, state-of-the-art thoracic MRI is now substituted for traditional imaging techniques and/or plays a complementary role in the management of patients with various chest diseases, and especially in the detection of pulmonary nodules and in thoracic oncology. In addition, MRI has continued to be developed to help overcome the limitations of computed tomography (CT) and nuclear medicine examinations. It can currently provide not only morphological, but also functional, physiological, pathophysiological, and molecular information at 1.5T with a gradual shift from 1.5T to 3T MR systems. In this review, we focus on these recent advances in MRI for pulmonary nodule detection and pulmonary nodule and mass evaluation by using noncontrast-enhanced and contrast-enhanced techniques as well as new molecular imaging methods such as chemical exchange saturation transfer imaging for a comparison with other modalities such as single or multidetector row CT, 18F-fluoro-2-deoxyglucose positron emission tomography (FDG-PET), and/or PET/CT. 4 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018. © 2018 International Society for Magnetic Resonance in Medicine.

  8. Long-term outcome following interstitial laser photocoagulation of benign cold thyroid nodules

    DEFF Research Database (Denmark)

    Døssing, Helle; Bennedbæk, Finn Noe; Hegedüs, Laszlo

    2011-01-01

    discomfort were assigned to ILP. ILP (using one laser fiber) was performed under continuous ultrasound (US) guidance and with an output power of 1.5-3.5 W. Thyroid nodule volume was assessed by US and thyroid function determined by routine assays, before and during follow-up. Pressure symptoms and cosmetic...... complaints were evaluated on a visual analogue scale (0-10 cm). Of the total patients, six had thyroid surgery 6 months after ILP and three were lost to follow-up. The median follow-up for the remaining 69 patients was 67 months (range 12-114). Results The overall median nodule volume decreased from 8.2 ml...

  9. Bilateral pulmonary nodules in an adult patient with bronchiolitis obliterans-organising pneumonia.

    Science.gov (United States)

    Kopanakis, Antonios; Golias, Christos; Pantentalakis, George; Patentalakis, Michalis; Mermigkis, Charalampos; Mermigkis, Christos; Charalabopoulos, Alexandros; Peschos, Dimitrios; Batistatou, Anna; Charalabopoulos, Konstantinos

    2009-01-01

    A 58-year-old male ex-smoker was admitted to hospital because of nodular infiltrates on chest x rays. He was complaining of fatigue, dyspnoea with exertion, low grade fever and weight loss. Physical examination was unremarkable. Bronchoscopy was inconclusive but revealed endobronchial lesions of chronic active inflammation. The diagnosis of cryptogenic organising pneumonitis bronchiolitis obliterans-organising pneumonia (COP-BOOP) was established by open lung biopsy. Proliferative bronchiolitis with regions of organising pneumonia is the characteristic feature of COP. The radiological picture of bilateral pulmonary nodules is an infrequent manifestation of COP. Lung biopsy, open or with video assistance thoracic surgery, is recommended to confirm the diagnosis.

  10. The Role of Nuclear Medicine in The Diagnosis and Management of Solitary Pulmonary Nodules

    Directory of Open Access Journals (Sweden)

    Farzaneh Shariati

    2013-10-01

    Full Text Available   Solitary pulmonary nodule (SPN is a frequent finding on the chest x-ray and computed tomography. Nuclear medicine techniques play an important role in the diagnosis and management of SPN. In the current review, we briefly will explain the different nuclear medicine modalities in this regard including positron emission tomography (PET using 18-F-FDG, and 11-C-Methionine, and single photon emission computerized tomography (SPECT using somatostatin receptor scintigraphy, 201-Thallium, and 99m-Tc-MIBI.  

  11. Single benign metastasising leiomyoma of an inguinal lymph node.

    NARCIS (Netherlands)

    Laban, KG; Tobon-Morales, Roberto; Hodge, Janice; Schreuder, HWR

    2016-01-01

    Benign metastasising leiomyoma (BML) is a rare benign disease associated with uterine leiomyoma and history of uterine surgery. It most frequently occurs in premenopausal woman, with a pulmonary localisation, and consisting of multiple nodules. We present an uncommon case of a 69-year-old woman with

  12. Development of a world wide web-based interactive education program to improve detectability of pulmonary nodules on chest radiographs

    International Nuclear Information System (INIS)

    Ohm, Joon Young; Kim, Jin Hwan; Kim, Sung Soo; Han, Ki Tae; Ahn, Young Seob; Shin, Byung Seok; Bae, Kyongtae T.

    2007-01-01

    To design and develop a World Wide Web-based education program that will allow trainees to interactively learn and improve the diagnostic capability of detecting pulmonary nodules on chest radiographs. Chest radiographs with known diagnosis were retrieved and selected from our institutional clinical archives. A database was constructed by sorting radiographs into three groups: normal, nodule, and false positive (i.e., nodule-like focal opacity). Each nodule was assigned with the degree of detectability: easy, intermediate, difficult, and likely missed. Nodules were characterized by their morphology (well-defined, ill-defined, irregular, faint) and by other associated pathologies or potentially obscuring structures. The Web site was organized into four sections: study, test, record and information. The Web site allowed a user interactively to undergo the training section appropriate to the user's diagnostic capability. The training was enhanced by means of clinical and other pertinent radiological findings included in the database. The outcome of the training was tested with clinical test radiographs that presented nodules or false positives with varying diagnostic difficulties. A World Wide Web-based education program is a promising technique that would allow trainees to interactively learn and improve the diagnostic capability of detecting and characterizing pulmonary nodules

  13. Transthoracic CT-guided biopsy with multiplanar reconstruction image improves diagnostic accuracy of solitary pulmonary nodules

    International Nuclear Information System (INIS)

    Ohno, Yoshiharu; Hatabu, Hiroto; Takenaka, Daisuke; Imai, Masatake; Ohbayashi, Chiho; Sugimura, Kazuro

    2004-01-01

    Objective: To evaluate the utility of multiplanar reconstruction (MPR) image for CT-guided biopsy and determine factors of influencing diagnostic accuracy and the pneumothorax rate. Materials and methods: 390 patients with 396 pulmonary nodules underwent transthoracic CT-guided aspiration biopsy (TNAB) and transthoracic CT-guided cutting needle core biopsy (TCNB) as follows: 250 solitary pulmonary nodules (SPNs) underwent conventional CT-guided biopsy (conventional method), 81 underwent CT-fluoroscopic biopsy (CT-fluoroscopic method) and 65 underwent conventional CT-guided biopsy in combination with MPR image (MPR method). Success rate, overall diagnostic accuracy, pneumothorax rate and total procedure time were compared in each method. Factors affecting diagnostic accuracy and pneumothorax rate of CT-guided biopsy were statistically evaluated. Results: Success rates (TNAB: 100.0%, TCNB: 100.0%) and overall diagnostic accuracies (TNAB: 96.9%, TCNB: 97.0%) of MPR were significantly higher than those using the conventional method (TNAB: 87.6 and 82.4%, TCNB: 86.3 and 81.3%) (P<0.05). Diagnostic accuracy were influenced by biopsy method, lesion size, and needle path length (P<0.05). Pneumothorax rate was influenced by pathological diagnostic method, lesion size, number of punctures and FEV1.0% (P<0.05). Conclusion: The use of MPR for CT-guided lung biopsy is useful for improving diagnostic accuracy with no significant increase in pneumothorax rate or total procedure time

  14. Diagnostic value of 18F-FDG-PET/CT for the evaluation of solitary pulmonary nodules: a systematic review and meta-analysis.

    Science.gov (United States)

    Ruilong, Zong; Daohai, Xie; Li, Geng; Xiaohong, Wang; Chunjie, Wang; Lei, Tian

    2017-01-01

    To carry out a meta-analysis on the performance of fluorine-18-fluorodeoxyglucose (F-FDG) PET/computed tomography (PET/CT) for the evaluation of solitary pulmonary nodules. In the meta-analysis, we performed searches of several electronic databases for relevant studies, including Google Scholar, PubMed, Cochrane Library, and several Chinese databases. The quality of all included studies was assessed by Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2). Two observers independently extracted data of eligible articles. For the meta-analysis, the total sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratios were pooled. A summary receiver operating characteristic curve was constructed. The I-test was performed to assess the impact of study heterogeneity on the results of the meta-analysis. Meta-regression and subgroup analysis were carried out to investigate the potential covariates that might have considerable impacts on heterogeneity. Overall, 12 studies were included in this meta-analysis, including a total of 1297 patients and 1301 pulmonary nodules. The pooled sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio with corresponding 95% confidence intervals (CIs) were 0.82 (95% CI, 0.76-0.87), 0.81 (95% CI, 0.66-0.90), 4.3 (95% CI, 2.3-7.9), and 0.22 (95% CI, 0.16-0.30), respectively. Significant heterogeneity was observed in sensitivity (I=81.1%) and specificity (I=89.6%). Subgroup analysis showed that the best results for sensitivity (0.90; 95% CI, 0.68-0.86) and accuracy (0.93; 95% CI, 0.90-0.95) were present in a prospective study. The results of our analysis suggest that PET/CT is a useful tool for detecting malignant pulmonary nodules qualitatively. Although current evidence showed moderate accuracy for PET/CT in differentiating malignant from benign solitary pulmonary nodules, further work needs to be carried out to improve its reliability.

  15. iPads and LCDs show similar performance in the detection of pulmonary nodules

    Science.gov (United States)

    McEntee, Mark F.; Lowe, Joanna; Butler, Marie Louise; Pietrzyk, Mariusz; Evanoff, Michael G.; Ryan, John; Brennan, Patrick C.; Rainford, Louise A.

    2012-02-01

    In February 2011 the University of Chicago Medical School distributed iPads to its trainee doctors for use when reviewing clinical information and images on the ward or clinics. The use of tablet computing devices is becoming widespread in medicine with Apple™ heralding them as "revolutionary" in medicine. The question arises, just because it is technical achievable to use iPads for clinical evaluation of images, should we do so? The current work assesses the diagnostic efficacy of iPads when compared with LCD secondary display monitors for identifying lung nodules on chest x-rays. Eight examining radiologists of the American Board of Radiology were involved in the assessment, reading chest images on both the iPad and the an off-the-shelf LCD monitor. Thirty chest images were shown to each observer, of which 15 had one or more lung nodules. Radiologists were asked to locate the nodules and score how confident they were with their decision on a scale of 1-5. An ROC and JAFROC analysis was performed and modalities were compared using DBM MRMC. The results demonstrate no significant differences in performance between the iPad and the LCD for the ROC AUC (p<0.075) or JAFROC FOM (p<0.059) for random readers and random cases. Sample size estimation showed that this result is significant at a power of 0.8 and an effect size of 0.05 for ROC and 0.07 for JAFROC. This work demonstrates that for the task of identifying pulmonary nodules, the use of the iPad does not significantly change performance compared to an off-the-shelf LCD.

  16. Differentiation between malignant and benign thyroid nodules and stratification of papillary thyroid cancer with aggressive histological features: Whole-lesion diffusion-weighted imaging histogram analysis.

    Science.gov (United States)

    Hao, Yonghong; Pan, Chu; Chen, WeiWei; Li, Tao; Zhu, WenZhen; Qi, JianPin

    2016-12-01

    To explore the usefulness of whole-lesion histogram analysis of apparent diffusion coefficient (ADC) derived from reduced field-of-view (r-FOV) diffusion-weighted imaging (DWI) in differentiating malignant and benign thyroid nodules and stratifying papillary thyroid cancer (PTC) with aggressive histological features. This Institutional Review Board-approved, retrospective study included 93 patients with 101 pathologically proven thyroid nodules. All patients underwent preoperative r-FOV DWI at 3T. The whole-lesion ADC assessments were performed for each patient. Histogram-derived ADC parameters between different subgroups (pathologic type, extrathyroidal extension, lymph node metastasis) were compared. Receiver operating characteristic curve analysis was used to determine optimal histogram parameters in differentiating benign and malignant nodules and predicting aggressiveness of PTC. Mean ADC, median ADC, 5 th percentile ADC, 25 th percentile ADC, 75 th percentile ADC, 95 th percentile ADC (all P histogram analysis might help to differentiate malignant nodules from benign ones and show the PTCs with extrathyroidal extension. J. Magn. Reson. Imaging 2016;44:1546-1555. © 2016 International Society for Magnetic Resonance in Medicine.

  17. The manifestation of 18F-FDG imaging of coincidence SPECT in benign pulmonary diseases

    International Nuclear Information System (INIS)

    Miao Jisheng; Liu Jinjun; Wu Jiyong; Pan Huizhong; Wang Huoqiang; Shen Yi; Shi Degang

    2001-01-01

    Objective: To study the uptake of the 18 F-FDG in the benign pulmonary diseases with dual head SPECT coincidence detection system. Methods: Scanning were performed with dual head SPECT coincidence detection system for patients with pulmonary diseases,the uptake and the imaging characteristic of the diseases were analysed. Results: 1) In 28 tuberculosis (TB) patients, 19 cases with a negative imaging (68%, 19/28), whereas 9 cases with a positive result (32%, 9/28). The T/N value of the TB is 1.7 +- 1.2, but the T/N of the lung cancer is 4.1 +- 2.4, significantly different from them. In the skin PPD test, 9 cases with positive scans showed a 16.2 (12 - 22) mm diameter red spot, but 7 cases of negative scans with a 8.6 (0 - 15) mm diameter, both also have a significant difference. 2) Out of the 8 patients suffered from sarcoidosis, among them 5 active stage with positive scans, whereas another 3 remission cases with negative results. 3) In 18 inflammation cases, positive imagings were showed in 6 patients with cryptococcosis, mycoplasma pneumonia, mycosis, organized pneumonia, lung abscess and bacteria pneumonia. Conclusions: In some benign pulmonary diseases, 18 F-FDG imaging can be positive also. Analysing the characteristic of the imaging could rise specificity in lung cancer and also give some new clues to treatment of these benign pulmonary diseases

  18. Role of high-resolution CT in the diagnosis of small pulmonary nodules coexisting with potentially operable lung cancer

    International Nuclear Information System (INIS)

    Yuan, Yue; Matsumoto, Tsuneo; Hiyama, Atsuto; Miura, Goji; Tanaka, Nobuyuki; Matsunaga, Naofumi

    2002-01-01

    The purpose of this study was to evaluate whether high-resolution CT (HRCT) could facilitate the preoperative diagnosis of one or two small nodules of 1 cm or less coexisting with a lung cancer, i.e., coexisting small nodule. This study included 27 coexisting small nodules in 24 potentially operable lung cancer patients. An observer study was performed by five radiologists. The observer performances in differentiating malignant from benign coexisting small nodules were evaluated on conventional CT and HRCT using receiver operating characteristic (ROC) analysis. The area under the ROC curve of five observers was 0.731 on HRCT and 0.578 on conventional CT in the differential diagnosis of coexisting small nodules. A significant diagnostic improvement was found on HRCT (p=0.031). This was especially evident for nodules of ground-glass attenuation (p=0.005). HRCT plays an important role in determining the treatment of potentially operable lung cancer patients with coexisting small nodules. (author)

  19. Inter- and intrascanner variability of pulmonary nodule volumetry on low-dose 64-row CT: an anthropomorphic phantom study

    Science.gov (United States)

    Xie, X; Willemink, M J; Zhao, Y; de Jong, P A; van Ooijen, P M A; Oudkerk, M; Greuter, M J W

    2013-01-01

    Objective: To assess inter- and intrascanner variability in volumetry of solid pulmonary nodules in an anthropomorphic thoracic phantom using low-dose CT. Methods: Five spherical solid artificial nodules [diameters 3, 5, 8, 10 and 12 mm; CT density +100 Hounsfield units (HU)] were randomly placed inside an anthropomorphic thoracic phantom in different combinations. The phantom was examined on two 64-row multidetector CT (64-MDCT) systems (CT-A and CT-B) from different vendors with a low-dose protocol. Each CT examination was performed three times. The CT examinations were evaluated twice by independent blinded observers. Nodule volume was semi-automatically measured by dedicated software. Interscanner variability was evaluated by Bland–Altman analysis and expressed as 95% confidence interval (CI) of relative differences. Intrascanner variability was expressed as 95% CI of relative variation from the mean. Results: No significant difference in CT-derived volume was found between CT-A and CT-B, except for the 3-mm nodules (pvolumetry of artificial pulmonary nodules between 5 mm and 12 mm in diameter. Inter- and intrascanner variability decreases at a larger nodule size to a maximum of 4.9% for ≥8 mm nodules. Advances in knowledge: The commonly accepted cut-off of 25% to determine nodule growth has the potential to be reduced for ≥8 mm nodules. This offers the possibility of reducing the interval for repeated CT scans in lung cancer screenings. PMID:23884758

  20. Differential diagnosis of solitary pulmonary nodules based on 99mTc-EDDA/HYNIC-TOC scintigraphy: the effect of tumour size on the optimal method of image assessment

    International Nuclear Information System (INIS)

    Plachcinska, Anna; Kusmierek, Jacek; Mikolajczak, Renata; Kozak, Jozef; Rzeszutek, Katarzyna

    2006-01-01

    The aim of the study was to determine an optimal method for the evaluation of scintigrams obtained with 99m Tc-EDDA/HYNIC-TOC for the purpose of differential diagnosis of solitary pulmonary nodules (SPNs) and to assess the diagnostic value of the method. Eighty-five patients (48 males and 37 females, mean age 57 years, range 34-78 years) were enrolled in the study. Patients underwent 99m Tc-EDDA/HYNIC-TOC scintigraphy for the purpose of differential diagnosis of SPNs (size between 1 and 4 cm). Images of all patients were evaluated visually in a prospective manner. Positive scintigraphic results were found in 37 out of 40 (93%) patients with malignant SPNs including 34 out of 35 (97%) patients with primary lung carcinoma. Two remaining false negative cases turned out to be metastatic lesions of malignant melanoma and leiomyosarcoma. Among 45 benign tumours, negative results were obtained in 31 cases (69%) and positive results in 14. The accuracy of the method was 80%. Analysis of the results of the visual assessment of scintigrams revealed a significantly higher frequency of false positive results among larger nodules (diameter at least 1.4 cm). Uptake of the tracer in those nodules was therefore assessed semi-quantitatively (using the tumour-to-background ratio), in expectation of an improvement in the low specificity of the visual method. The semi-quantitative assessment reduced the total number of false positive results in a subgroup of larger nodules from 13 to six, while preserving the high sensitivity of the method. The combination of visual analysis (for lesions smaller than 1.4 cm in diameter) and semi-quantitative assessment (for larger lesions) provided a high sensitivity of the method and significantly improved its specificity (84%) and accuracy (88%) in comparison with visual analysis (p<0.05). (orig.)

  1. Differential diagnosis of solitary pulmonary nodules based on 99mTc-EDDA/HYNIC-TOC scintigraphy: the effect of tumour size on the optimal method of image assessment.

    Science.gov (United States)

    Płachcińska, Anna; Mikołajczak, Renata; Kozak, Józef; Rzeszutek, Katarzyna; Kuśmierek, Jacek

    2006-09-01

    The aim of the study was to determine an optimal method for the evaluation of scintigrams obtained with (99m)Tc-EDDA/HYNIC-TOC for the purpose of differential diagnosis of solitary pulmonary nodules (SPNs) and to assess the diagnostic value of the method. Eighty-five patients (48 males and 37 females, mean age 57 years, range 34-78 years) were enrolled in the study. Patients underwent (99m)Tc-EDDA/HYNIC-TOC scintigraphy for the purpose of differential diagnosis of SPNs (size between 1 and 4 cm). Images of all patients were evaluated visually in a prospective manner. Positive scintigraphic results were found in 37 out of 40 (93%) patients with malignant SPNs including 34 out of 35 (97%) patients with primary lung carcinoma. Two remaining false negative cases turned out to be metastatic lesions of malignant melanoma and leiomyosarcoma. Among 45 benign tumours, negative results were obtained in 31 cases (69%) and positive results in 14. The accuracy of the method was 80%. Analysis of the results of the visual assessment of scintigrams revealed a significantly higher frequency of false positive results among larger nodules (diameter at least 1.4 cm). Uptake of the tracer in those nodules was therefore assessed semi-quantitatively (using the tumour-to-background ratio), in expectation of an improvement in the low specificity of the visual method. The semi-quantitative assessment reduced the total number of false positive results in a subgroup of larger nodules from 13 to six, while preserving the high sensitivity of the method. The combination of visual analysis (for lesions smaller than 1.4 cm in diameter) and semi-quantitative assessment (for larger lesions) provided a high sensitivity of the method and significantly improved its specificity (84%) and accuracy (88%) in comparison with visual analysis (p<0.05).

  2. Computer-aided detection of pulmonary nodules: a comparative study using the public LIDC/IDRI database

    International Nuclear Information System (INIS)

    Jacobs, Colin; Prokop, Mathias; Rikxoort, Eva M. van; Ginneken, Bram van; Murphy, Keelin; Schaefer-Prokop, Cornelia M.

    2016-01-01

    To benchmark the performance of state-of-the-art computer-aided detection (CAD) of pulmonary nodules using the largest publicly available annotated CT database (LIDC/IDRI), and to show that CAD finds lesions not identified by the LIDC's four-fold double reading process. The LIDC/IDRI database contains 888 thoracic CT scans with a section thickness of 2.5 mm or lower. We report performance of two commercial and one academic CAD system. The influence of presence of contrast, section thickness, and reconstruction kernel on CAD performance was assessed. Four radiologists independently analyzed the false positive CAD marks of the best CAD system. The updated commercial CAD system showed the best performance with a sensitivity of 82 % at an average of 3.1 false positive detections per scan. Forty-five false positive CAD marks were scored as nodules by all four radiologists in our study. On the largest publicly available reference database for lung nodule detection in chest CT, the updated commercial CAD system locates the vast majority of pulmonary nodules at a low false positive rate. Potential for CAD is substantiated by the fact that it identifies pulmonary nodules that were not marked during the extensive four-fold LIDC annotation process. (orig.)

  3. The experimental study and clinical application on the detection of pulmonary nodules with low-dose multislice spiral CT

    International Nuclear Information System (INIS)

    Wu Xiaohua; Ma Daqing; Zhang Zhongjia; Ji Jingling; Zhang Yansong

    2004-01-01

    Objective: To investigate the detection rate of pulmonary nodules ,especially nodules ≤5 mm, in variable low-doses, and to evaluate the imaging quality of low-dose MSCT. Methods: Six postmortem specimens of patients with pneumoconiosis after necropsy were fixed at end-inspiratory volume. The fixed specimens were examined by using MSCT with standard dose (130 mA) and low-dose (50, 30, 10 mA, respectively). Low-dose MSCT scans of 40 asymptomatic volunteers and 60 patients with pulmonary metastasis were also examined with 30 mA. The numbers of pulmonary nodules less than 5 mm at standard-dose and different low-dose were recorded. Nodules were assessed by diagnostic confidence ('definite nodule', 'questionable nodule', and 'definite not nodule'). The number of images with artifact in specimens and in 40 volunteers and 60 patients with pulmonary metastasis were recorded. Results: In specimen's study, the Kappa values of groups of low-dose (50, 30, 10 mA) were 0.515, 0.242, and 0.154, respectively. The group of 50 mA had a good coincidence with standard-dose group by U test. The sensitivity of group 50, 30, 10 mA was 88.0%, 78.4%, and 75.0%, respectively. The positive predictive values of which were 98%, 94%, and 93%, respectively. The correction rates of which were 85%, 73%, and 69%, respectively. In specimens' images, subtle linear artifact was showed only in paravertebral lung field in 21 images of 31 at the group of 10 mA. Linear artifacts that affected small nodule detection were showed in lung apexes in 3 of 100 subjects. Conclusion: Low-dose MSCT is expected to improve early detection of lung cancer. Pulmonary nodules less than 5 mm could be reliably detected at 50 mA tube current in specimens. Low-dose CT (30 mA) showed satisfactory imaging quality in our study. Low-dose CT screening for lung cancer may be applied if situation permits. (authors)

  4. The Effects of Iodine Attenuation on Pulmonary Nodule Volumetry using Novel Dual-Layer Computed Tomography Reconstructions

    NARCIS (Netherlands)

    den Harder, A M; Bangert, F; van Hamersvelt, R W; Leiner, T; Milles, Julien; Schilham, A M R; Willemink, M J; de Jong, P A

    2017-01-01

    OBJECTIVES: To assess the effect of iodine attenuation on pulmonary nodule volumetry using virtual non-contrast (VNC) and mono-energetic reconstructions. METHODS: A consecutive series of patients who underwent a contrast-enhanced chest CT scan were included. Images were acquired on a novel

  5. Comparison of digital tomosynthesis and chest radiography for the detection of pulmonary nodules: systematic review and meta-analysis.

    Science.gov (United States)

    Kim, Jun H; Lee, Kyung H; Kim, Kyoung-Tae; Kim, Hyun J; Ahn, Hyeong S; Kim, Yeo J; Lee, Ha Y; Jeon, Yong S

    2016-12-01

    To compare the diagnostic accuracy of digital tomosynthesis (DTS) with that of chest radiography for the detection of pulmonary nodules by meta-analysis. A systematic literature search was performed to identify relevant original studies from 1 January 1 1976 to 31 August 31 2016. The quality of included studies was assessed by quality assessment of diagnostic accuracy studies-2. Per-patient data were used to calculate the sensitivity and specificity and per-lesion data were used to calculate the detection rate. Summary receiver-operating characteristic curves were drawn for pulmonary nodule detection. 16 studies met the inclusion criteria. 1017 patients on a per-patient basis and 2159 lesions on a per-lesion basis from 16 eligible studies were evaluated. The pooled patient-based sensitivity of DTS was 0.85 [95% confidence interval (CI) 0.83-0.88] and the specificity was 0.95 (0.93-0.96). The pooled sensitivity and specificity of chest radiography were 0.47 (0.44-0.51) and 0.37 (0.34-0.40), respectively. The per-lesion detection rate was 2.90 (95% CI 2.63-3.19). DTS has higher diagnostic accuracy than chest radiography for detection of pulmonary nodules. Chest radiography has low sensitivity but similar specificity, comparable with that of DTS. Advances in knowledge: DTS has higher diagnostic accuracy than chest radiography for the detection of pulmonary nodules.

  6. Detection of pulmonary nodules on lung X-ray images. Studies on multi-resolutional filter and energy subtraction images

    International Nuclear Information System (INIS)

    Sawada, Akira; Sato, Yoshinobu; Kido, Shoji; Tamura, Shinichi

    1999-01-01

    The purpose of this work is to prove the effectiveness of an energy subtraction image for the detection of pulmonary nodules and the effectiveness of multi-resolutional filter on an energy subtraction image to detect pulmonary nodules. Also we study influential factors to the accuracy of detection of pulmonary nodules from viewpoints of types of images, types of digital filters and types of evaluation methods. As one type of images, we select an energy subtraction image, which removes bones such as ribs from the conventional X-ray image by utilizing the difference of X-ray absorption ratios at different energy between bones and soft tissue. Ribs and vessels are major causes of CAD errors in detection of pulmonary nodules and many researches have tried to solve this problem. So we select conventional X-ray images and energy subtraction X-ray images as types of images, and at the same time select ∇ 2 G (Laplacian of Guassian) filter, Min-DD (Minimum Directional Difference) filter and our multi-resolutional filter as types of digital filters. Also we select two evaluation methods and prove the effectiveness of an energy subtraction image, the effectiveness of Min-DD filter on a conventional X-ray image and the effectiveness of multi-resolutional filter on an energy subtraction image. (author)

  7. Persistent pulmonary subsolid nodules with solid portions of 5 mm or smaller: Their natural course and predictors of interval growth

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jong Hyuk [Seoul National University College of Medicine, and Institute of Radiation Medicine, Seoul National University Medical Research Center, Department of Radiology, Seoul (Korea, Republic of); Park, Chang Min [Seoul National University College of Medicine, and Institute of Radiation Medicine, Seoul National University Medical Research Center, Department of Radiology, Seoul (Korea, Republic of); Seoul National University, Cancer Research Institute, Seoul (Korea, Republic of); Duke University Medical Center, Department of Radiology, Durham, NC (United States); Lee, Sang Min [University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology, Seoul (Korea, Republic of); Kim, Hyungjin [Seoul National University College of Medicine, and Institute of Radiation Medicine, Seoul National University Medical Research Center, Department of Radiology, Seoul (Korea, Republic of); Air Force Education and Training Command, Aerospace Medical Group, Jinju (Korea, Republic of); McAdams, H.P. [Duke University Medical Center, Department of Radiology, Durham, NC (United States); Goo, Jin Mo [Seoul National University College of Medicine, and Institute of Radiation Medicine, Seoul National University Medical Research Center, Department of Radiology, Seoul (Korea, Republic of); Seoul National University, Cancer Research Institute, Seoul (Korea, Republic of)

    2016-06-15

    To investigate the natural course of persistent pulmonary subsolid nodules (SSNs) with solid portions ≤5 mm and the clinico-radiological features that influence interval growth over follow-ups. From 2005 to 2013, the natural courses of 213 persistent SSNs in 213 patients were evaluated. To identify significant predictors of interval growth, Kaplan-Meier analysis and Cox proportional hazard regression analysis were performed. Among the 213 nodules, 136 were pure ground-glass nodules (GGNs; growth, 18; stable, 118) and 77 were part-solid GGNs with solid portions ≤5 mm (growth, 24; stable, 53). For all SSNs, lung cancer history (p = 0.001), part-solid GGNs (p < 0.001), and nodule diameter (p < 0.001) were significant predictors for interval growth. On subgroup analysis, nodule diameter was an independent predictor for the interval growth of both pure GGNs (p < 0.001), and part-solid GGNs (p = 0.037). For part-solid GGNs, lung cancer history (p = 0.002) was another significant predictor of the interval growth. Interval growth of pure GGNs ≥10 mm and part-solid GGNs ≥8 mm were significantly more frequent than in pure GGNs <10 mm (p < 0.001) and part-solid GGNs <8 mm (p = 0.003), respectively. The natural course of SSNs with solid portions ≤5 mm differed significantly according to their nodule type and nodule diameters, with which their management can be subdivided. (orig.)

  8. Characterization of fibrillar collagens and extracellular matrix of glandular benign prostatic hyperplasia nodules.

    Directory of Open Access Journals (Sweden)

    Tyler M Bauman

    Full Text Available Recent studies have associated lower urinary tract symptoms (LUTS in men with prostatic fibrosis, but a definitive link between collagen deposition and LUTS has yet to be demonstrated. The objective of this study was to evaluate ECM and collagen content within normal glandular prostate tissue and glandular BPH, and to evaluate the association of clinical parameters of LUTS with collagen content.Fibrillar collagen and ECM content was assessed in normal prostate (48 patients and glandular BPH nodules (24 patients using Masson's trichrome stain and Picrosirius red stain. Second harmonic generation (SHG imaging was used to evaluate collagen content. Additional BPH tissues (n = 47 were stained with Picrosirius red and the association between clinical parameters of BPH/LUTS and collagen content was assessed.ECM was similar in normal prostate and BPH (p = 0.44. Total collagen content between normal prostate and glandular BPH was similar (p = 0.27, but a significant increase in thicker collagen bundles was observed in BPH (p = 0.045. Using SHG imaging, collagen content in BPH (mean intensity = 62.52; SEM = 2.74 was significantly higher than in normal prostate (51.77±3.49; p = 0.02. Total collagen content was not associated with treatment with finasteride (p = 0.47 or α-blockers (p = 0.52, pre-TURP AUA symptom index (p = 0.90, prostate-specific antigen (p = 0.86, post-void residual (PVR; p = 0.32, prostate size (p = 0.21, or post-TURP PVR (p = 0.51. Collagen content was not associated with patient age in patients with BPH, however as men aged normal prostatic tissue had a decreased proportion of thick collagen bundles.The proportion of larger bundles of collagen, but not total collagen, is increased in BPH nodules, suggesting that these large fibers may play a role in BPH/LUTS. Total collagen content is independent of clinical parameters of BPH and LUTS. If fibrosis and overall ECM deposition are

  9. Sensitivity and accuracy of volumetry of pulmonary nodules on low-dose 16- and 64-row multi-detector CT: an anthropomorphic phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Xueqian; Zhao, Yingru; Ooijen, Peter M.A. van; Vliegenthart, Rozemarijn [University of Groningen, University Medical Center Groningen, Department of Radiology, EB44, P.O. Box 30.001, Groningen (Netherlands); University of Groningen, University Medical Center Groningen, Center for Medical Imaging-North East Netherlands, Department of Radiology, Groningen (Netherlands); Snijder, Roland A.; Greuter, Marcel J.W. [University of Groningen, University Medical Center Groningen, Department of Radiology, EB44, P.O. Box 30.001, Groningen (Netherlands); Jong, Pim A. de [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Oudkerk, Matthijs [University of Groningen, University Medical Center Groningen, Center for Medical Imaging-North East Netherlands, Department of Radiology, Groningen (Netherlands); Bock, Geertruida H. de [University of Groningen, University Medical Center Groningen, Department of Epidemiology, Groningen (Netherlands)

    2013-01-15

    To assess the sensitivity of detection and accuracy of volumetry by manual and semi-automated quantification of artificial pulmonary nodules in an anthropomorphic thoracic phantom on low-dose CT. Fifteen artificial spherical nodules (diameter 3, 5, 8, 10 and 12 mm; CT densities -800, -630 and +100 HU) were randomly placed inside an anthropomorphic thoracic phantom. The phantom was examined on 16- and 64-row multidetector CT with a low-dose protocol. Two independent blinded observers screened for pulmonary nodules. Nodule diameter was measured manually, and volume calculated. For solid nodules (+100 HU), diameter and volume were also evaluated by semi-automated software. Differences in observed volumes between the manual and semi-automated method were evaluated by a t-test. Sensitivity was 100 % for all nodules of >5 mm and larger, 60-80 % for solid and 0-20 % for non-solid 3-mm nodules. No false-positive nodules but high inter-observer reliability and inter-technique correlation were found. Volume was underestimated manually by 24.1 {+-} 14.0 % for nodules of any density, and 26.4 {+-} 15.5 % for solid nodules, compared with 7.6 {+-} 8.5 % (P < 0.01) semi-automatically. In an anthropomorphic phantom study, the sensitivity of detection is 100 % for nodules of >5 mm in diameter. Semi-automated volumetry yielded more accurate nodule volumes than manual measurements. (orig.)

  10. Thoracoscopic detection of occult indeterminate pulmonary nodules using bronchoscopic pleural dye marking

    Directory of Open Access Journals (Sweden)

    William S. Krimsky

    2014-02-01

    Full Text Available Background: The annual incidence of a small indeterminate pulmonary nodule (IPN on computed tomography (CT scan remains high. While traditional paradigms exist, the integration of new technologies into these diagnostic and treatment algorithms can result in alternative, potentially more efficient methods of managing these findings. Methods: We report on an alternative diagnostic and therapeutic strategy for the management of an IPN. This approach combines electromagnetic navigational bronchoscopy (ENB with an updated approach to placement of a pleural dye marker. This technique lends itself to a minimally invasive wedge resection via either video-assisted thoracoscopic surgery (VATS or a robotic approach. Results: Subsequent to alterations in the procedure, a cohort of 22 patients with an IPN was reviewed. Navigation was possible in 21 out of 22 patients with one patient excluded based on airway anatomy. The remaining 21 patients underwent ENB with pleural dye marking followed by minimally invasive wedge resection. The median size of the nodules was 13.4 mm (range: 7–29. There were no complications from the ENB procedure. Indigo carmine dye was used in ten patients. Methylene blue was used in the remaining 11 patients. In 81% of cases, the visceral pleural marker was visible at the time of surgery. In one patient, there was diffuse staining of the parietal pleura. In three additional patients, no dye was identified within the hemithorax. In all cases where dye marker was present on the visceral pleural surface, it was in proximity to the IPN and part of the excised specimen. Conclusions: ENB with pleural dye marking can provide a safe and effective method to localize an IPN and can allow for subsequent minimally invasive resection. Depending on the characteristics and location of the nodule, this method may allow more rapid identification intraoperatively.

  11. Computer-aided diagnosis of pulmonary nodules on CT scans: Segmentation and classification using 3D active contours

    International Nuclear Information System (INIS)

    Way, Ted W.; Hadjiiski, Lubomir M.; Sahiner, Berkman; Chan, H.-P.; Cascade, Philip N.; Kazerooni, Ella A.; Bogot, Naama; Zhou Chuan

    2006-01-01

    We are developing a computer-aided diagnosis (CAD) system to classify malignant and benign lung nodules found on CT scans. A fully automated system was designed to segment the nodule from its surrounding structured background in a local volume of interest (VOI) and to extract image features for classification. Image segmentation was performed with a three-dimensional (3D) active contour (AC) method. A data set of 96 lung nodules (44 malignant, 52 benign) from 58 patients was used in this study. The 3D AC model is based on two-dimensional AC with the addition of three new energy components to take advantage of 3D information: (1) 3D gradient, which guides the active contour to seek the object surface (2) 3D curvature, which imposes a smoothness constraint in the z direction, and (3) mask energy, which penalizes contours that grow beyond the pleura or thoracic wall. The search for the best energy weights in the 3D AC model was guided by a simplex optimization method. Morphological and gray-level features were extracted from the segmented nodule. The rubber band straightening transform (RBST) was applied to the shell of voxels surrounding the nodule. Texture features based on run-length statistics were extracted from the RBST image. A linear discriminant analysis classifier with stepwise feature selection was designed using a second simplex optimization to select the most effective features. Leave-one-case-out resampling was used to train and test the CAD system. The system achieved a test area under the receiver operating characteristic curve (A z ) of 0.83±0.04. Our preliminary results indicate that use of the 3D AC model and the 3D texture features surrounding the nodule is a promising approach to the segmentation and classification of lung nodules with CAD. The segmentation performance of the 3D AC model trained with our data set was evaluated with 23 nodules available in the Lung Image Database Consortium (LIDC). The lung nodule volumes segmented by the 3D AC

  12. Learning aspects and potential pitfalls regarding detection of pulmonary nodules in chest tomosynthesis and proposed related quality criteria

    International Nuclear Information System (INIS)

    Asplund, Sara; Johnsson, Aase A.; Vikgren, Jenny

    2011-01-01

    Background In chest tomosynthesis, low-dose projections collected over a limited angular range are used for reconstruction of an arbitrary number of section images of the chest, resulting in a moderately increased radiation dose compared to chest radiography. Purpose To investigate the effects of learning with feedback on the detection of pulmonary nodules for observers with varying experience of chest tomosynthesis, to identify pitfalls regarding detection of pulmonary nodules, and present suggestions for how to avoid them, and to adapt the European quality criteria for chest radiography and computed tomography (CT) to chest tomosynthesis. Material and Methods Six observers analyzed tomosynthesis cases for presence of nodules in a jackknife alternative free-response receiver-operating characteristics (JAFROC) study. CT was used as reference. The same tomosynthesis cases were analyzed before and after learning with feedback, which included a collective learning session. The difference in performance between the two readings was calculated using the JAFROC figure of merit as principal measure of detectability. Results Significant improvement in performance after learning with feedback was found only for observers inexperienced in tomosynthesis. At the collective learning session, localization of pleural and sub pleural nodules or structures was identified as the main difficulty in analyzing tomosynthesis images. Conclusion The results indicate that inexperienced observers can reach a high level of performance regarding nodule detection in tomosynthesis after learning with feedback and that the main problem with chest tomosynthesis is related to the limited depth resolution

  13. 68Ga-DOTATATE PET/CT imaging of indeterminate pulmonary nodules and lung cancer.

    Directory of Open Access Journals (Sweden)

    Ronald Walker

    Full Text Available 18F-FDG PET/CT is widely used to evaluate indeterminate pulmonary nodules (IPNs. False positive results occur, especially from active granulomatous nodules. A PET-based imaging agent with superior specificity to 18F-FDG for IPNs, is badly needed, especially in areas of endemic granulomatous nodules. Somatostatin receptors (SSTR are expressed in many malignant cells including small cell and non-small cell lung cancers (NSCLCs. 68Ga-DOTATATE, a positron emitter labeled somatostatin analog, combined with PET/CT imaging, may improve the diagnosis of IPNs over 18F-FDG by reducing false positives. Our study purpose was to test this hypothesis in our region with high endemic granulomatous IPNs.We prospectively performed 68Ga-DOTATATE PET/CT and 18F-FDG PET/CT scans in the same 30 patients with newly diagnosed, treatment-naïve lung cancer (N = 14 or IPNs (N = 15 and one metastatic nodule. 68Ga-DOTATATE SUVmax levels at or above 1.5 were considered likely malignant. We analyzed the scan results, correlating with ultimate diagnosis via biopsy or 2-year chest CT follow-up. We also correlated 68Ga-DOTATATE uptake with immunohistochemical (IHC staining for SSTR subtype 2A (SSTR2A in pathological specimens.We analyzed 31 lesions in 30 individuals, with 14 (45% being non-neuroendocrine lung cancers and 1 (3% being metastatic disease. McNemar's result comparing the two radiopharmaceuticals (p = 0.65 indicates that their accuracy of diagnosis in this indication are equivalent. 68Ga-DOTATATE was more specific (94% compared to 81% and less sensitive 73% compared to 93% than 18F-FDG. 68Ga-DOTATATE uptake correlated with SSTR2A expression in tumor stroma determined by immunohistochemical (IHC staining in 5 of 9 (55% NSCLCs.68Ga-DOTATATE and 18F-FDG PET/CT had equivalent accuracy in the diagnosis of non-neuroendocrine lung cancer and 68Ga-DOTATATE was more specific than 18F-FDG for the diagnosis of IPNs. IHC staining for SSTR2A receptor expression correlated with

  14. Distress and patient-centered communication among veterans with incidental (not screen-detected) pulmonary nodules. A cohort study.

    Science.gov (United States)

    Slatore, Christopher G; Golden, Sara E; Ganzini, Linda; Wiener, Renda Soylemez; Au, David H

    2015-02-01

    Incidental pulmonary nodule detection is postulated to cause distress, but the frequency and magnitude of that distress have not been reported. The quality of patient-clinician communication and the perceived risk of lung cancer may influence distress Objectives: To evaluate the association of communication processes with distress and the perceived risk of lung cancer using validated instruments. We conducted a prospective cohort study of patients with incidentally detected nodules who received care at one Department of Veterans Affairs Medical Center. We measured distress with the Impact of Event Scale and patient-centered communication with the Consultation Care Measure, both validated instruments. Risk of lung cancer was self-reported by participants. We used multivariable adjusted logistic regression to measure the association of communication quality with distress. Among 122 Veterans with incidental nodules, 23%, 12%, and 4% reported experiencing mild, moderate, and severe distress, respectively, at the time they were informed of the pulmonary nodule. Participant-reported risk of lung cancer was not associated with distress. In the adjusted model, high-quality communication was associated with decreased distress (odds ratio [OR] = 0.28, 95% confidence interval [CI] = 0.08-1.00, P = 0.05). Among participants who reported a risk of malignancy of 30% or less, high-quality communication was associated with decreased distress (OR = 0.15, 95% CI = 0.02-0.92, P = 0.04), but was not associated with distress for those who reported a risk greater than 30% (OR = 0.12 (95% CI = 0.00-3.97, P = 0.24), although the P value for interaction was not significant. Veterans with incidental pulmonary nodules frequently reported inadequate information exchange regarding their nodule. Many patients experience distress after they are informed that they have a pulmonary nodule, and high-quality patient-clinician communication is associated with

  15. Sensitivity and accuracy of volumetry of pulmonary nodules on low-dose 16- and 64-row multi-detector CT: an anthropomorphic phantom study

    International Nuclear Information System (INIS)

    Xie, Xueqian; Zhao, Yingru; Ooijen, Peter M.A. van; Vliegenthart, Rozemarijn; Snijder, Roland A.; Greuter, Marcel J.W.; Jong, Pim A. de; Oudkerk, Matthijs; Bock, Geertruida H. de

    2013-01-01

    To assess the sensitivity of detection and accuracy of volumetry by manual and semi-automated quantification of artificial pulmonary nodules in an anthropomorphic thoracic phantom on low-dose CT. Fifteen artificial spherical nodules (diameter 3, 5, 8, 10 and 12 mm; CT densities -800, -630 and +100 HU) were randomly placed inside an anthropomorphic thoracic phantom. The phantom was examined on 16- and 64-row multidetector CT with a low-dose protocol. Two independent blinded observers screened for pulmonary nodules. Nodule diameter was measured manually, and volume calculated. For solid nodules (+100 HU), diameter and volume were also evaluated by semi-automated software. Differences in observed volumes between the manual and semi-automated method were evaluated by a t-test. Sensitivity was 100 % for all nodules of >5 mm and larger, 60-80 % for solid and 0-20 % for non-solid 3-mm nodules. No false-positive nodules but high inter-observer reliability and inter-technique correlation were found. Volume was underestimated manually by 24.1 ± 14.0 % for nodules of any density, and 26.4 ± 15.5 % for solid nodules, compared with 7.6 ± 8.5 % (P 5 mm in diameter. Semi-automated volumetry yielded more accurate nodule volumes than manual measurements. (orig.)

  16. 99Tcm-MIBI imaging in diagnosing benign/malign pulmonary disease and analysis of lung cancer DNA content

    International Nuclear Information System (INIS)

    Feng Yanlin; Tan Jiaju; Yang Jie; Zhu Zheng; Yu Fengwen; He Xiaohong; Huang Kemin; Yuan Baihong; Su Shaodi

    2002-01-01

    Objective: To evaluate the value of 99 Tc m -methoxyisobutylisonitrile (MIBI) lung imaging in diagnosing benign/malign pulmonary disease and the relation of 99 Tc m -MIBI uptake ratio (UR) with lung cancer DNA content. Methods: Early and delay imaging were performed on 27 cases of benign lung disease and 46 cases of malign lung disease. Visual analysis of the images and T/N uptake ratio measurement were performed on every case. Cancer cell DNA content and DNA index (DI) were measured in 24 cases of malign pulmonary disease. Results: The delay phase UR was 1.13 ± 0.19 in benign disease group, and the delay phase UR was 1.45 ± 0.21 in malign disease group (t6.51, P 99 Tc m -MIBI is not an ideal imaging agent for differentiating pulmonary benign/malign disease. Lung cancer DNA content may be reflected by delay phase UR

  17. Non-invasive Characterization of the Histopathologic Features of Pulmonary Nodules of the Lung Adenocarcinoma Spectrum using Computer Aided Nodule Assessment and Risk Yield (CANARY) – a Pilot Study

    Science.gov (United States)

    Maldonado, Fabien; Boland, Jennifer M.; Raghunath, Sushravya; Aubry, Marie Christine; Bartholmai, Brian J.; deAndrade, Mariza; Hartman, Thomas E.; Karwoski, Ronald A.; Rajagopalan, Srinivasan; Sykes, Anne-Marie; Yang, Ping; Yi, Eunhee S.; Robb, Richard A.; Peikert, Tobias

    2013-01-01

    Introduction Pulmonary nodules of the adenocarcinoma spectrum are characterized by distinctive morphological and radiological features and variable prognosis. Non-invasive high-resolution computed-tomography (HRCT)-based risk stratification tools are needed to individualize their management. Methods Radiological measurements of histopathologic tissue invasion were developed in a training set of 54 pulmonary nodules of the adenocarcinoma spectrum and validated in 86 consecutively resected nodules. Nodules were isolated and characterized by computer-aided analysis and data were analyzed by Spearman correlation, sensitivity, specificity as well as the positive and negative predictive values. Results Computer Aided Nodule Assessment and Risk Yield (CANARY) can non-invasively characterize pulmonary nodules of the adenocarcinoma spectrum. Unsupervised clustering analysis of HRCT data identified 9 unique exemplars representing the basic radiologic building blocks of these lesions. The exemplar distribution within each nodule correlated well with the proportion of histologic tissue invasion, Spearman R=0.87,p < 0.0001 and 0.89,p < 0.0001 for the training and the validation set, respectively. Clustering of the exemplars in three-dimensional space corresponding to tissue invasion and lepidic growth was used to develop a CANARY decision algorithm, which successfully categorized these pulmonary nodules as “aggressive” (invasive adenocarcinoma) or “indolent” (adenocarcinoma in situ and minimally invasive adenocarcinoma). Sensitivity, specificity, positive predictive value and negative predictive value of this approach for the detection of “aggressive” lesions were 95.4%, 96.8%, 95.4% and 96.8%, respectively in the training set and 98.7%, 63.6%, 94.9% and 87.5%, respectively in the validation set. Conclusion CANARY represents a promising tool to non-invasively risk stratify pulmonary nodules of the adenocarcinoma spectrum. PMID:23486265

  18. Significance and management of computed tomography detected pulmonary nodules: a report from the National Wilms Tumor Study Group

    International Nuclear Information System (INIS)

    Meisel, Jay A.; Guthrie, Katherine A.; Breslow, Norman E.; Donaldson, Sarah S.; Green, Daniel M.

    1999-01-01

    Purpose: To define the optimal treatment for children with Wilms tumor who have pulmonary nodules identified on chest computed tomography (CT) scan, but have a negative chest radiograph, we evaluated the outcome of all such patients randomized or followed on National Wilms Tumor Study (NWTS)-3 and -4. Patients and Methods: We estimated the event-free and overall survival percentages of 53 patients with favorable histology tumors and pulmonary densities identified only by CT scan (CT-only) who were treated as Stage IV with intensive doxorubicin-containing chemotherapy and whole-lung irradiation, and compared these to the event-free and overall survival percentages of 37 CT-only patients who were treated less aggressively based on the extent of locoregional disease with 2 or 3 drugs, and without whole-lung irradiation. Results: The 4-year event-free and overall survival percentages of the 53 patients with CT-only nodules and favorable histology Wilms tumor who were treated as Stage IV were 89% and 91%, respectively. The 4-year event-free and overall survival percentages for the 37 patients with CT-only nodules and favorable histology who were treated according to the extent of locoregional disease were 80% and 85%, respectively. The differences observed between the 2 groups were not statistically significant. Among the patients who received whole-lung irradiation, there were fewer pulmonary relapses, but more deaths attributable to lung toxicity. Conclusions: The current data raise the possibility that children with Wilms tumor and CT-only pulmonary nodules who receive whole lung irradiation have fewer pulmonary relapses, but a greater number of deaths due to treatment toxicity. The role of whole lung irradiation in the treatment of this group of patients cannot be definitively determined based on the present data. Prolonged follow-up of this group of patients is necessary to accurately estimate the frequency of late, treatment-related mortality

  19. Is Diagnostic Performance of Quantitative 2D-Shear Wave Elastography Optimal for Clinical Classification of Benign and Malignant Thyroid Nodules?: A Systematic Review and Meta-analysis.

    Science.gov (United States)

    Nattabi, Haliimah A; Sharif, Norhafidzah M; Yahya, Noorazrul; Ahmad, Rozilawati; Mohamad, Mazlyfarina; Zaki, Faizah M; Yusoff, Ahmad N

    2017-10-17

    This study is a dedicated 2D-shear wave elastography (2D-SWE) review aimed at systematically eliciting up-to-date evidence of its clinical value in differential diagnosis of benign and malignant thyroid nodules. PubMed, Web of Science, and Scopus databases were searched for studies assessing the diagnostic value of 2D-SWE for thyroid malignancy risk stratification published until December 2016. The retrieved titles and abstracts were screened and evaluated according to the predefined inclusion and exclusion criteria. Methodological quality of the studies was assessed using the Quality Assessment of Studies of Diagnostic Accuracy included in Systematic Review 2 (QUADAS-2) tool. Extracted 2D-SWE diagnostic performance data were meta-analyzed to assess the summary sensitivity, specificity, and area under the receiver operating characteristic curve. After stepwise review, 14 studies in which 2D-SWE was used to evaluate 2851 thyroid nodules (1092 malignant, 1759 benign) from 2139 patients were selected for the current study. Study quality on QUADAS-2 assessment was moderate to high. The summary sensitivity, specificity and area under the receiver operating characteristic curve of 2D-SWE for differential diagnosis of benign and malignant thyroid nodules were 0.66 (95% confidence interval [CI]: 0.64-0.69), 0.78 (CI: 0.76-0.80), and 0.851 (Q* = 0.85), respectively. The pooled diagnostic odds ratio, negative likelihood ratio, and positive likelihood ratio were 12.73 (CI: 8.80-18.43), 0.31 (CI: 0.22-0.44), and 3.87 (CI: 2.83-5.29), respectively. Diagnostic performance of quantitative 2D-SWE for malignancy risk stratification of thyroid nodules is suboptimal with mediocre sensitivity and specificity, contrary to earlier reports of excellence. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  20. Automatic classification of pulmonary peri-fissural nodules in computed tomography using an ensemble of 2D views and a convolutional neural network out-of-the-box

    NARCIS (Netherlands)

    Ciompi, Francesco; de Hoop, Bartjan; van Riel, Sarah J.; Chung, Kaman; Scholten, Ernst Th.; Oudkerk, Matthijs; de Jong, Pim A.; Prokop, Mathias; van Ginneken, Bram

    2015-01-01

    In this paper, we tackle the problem of automatic classification of pulmonary peri-fissural nodules (PFNs). The classification problem is formulated as a machine learning approach, where detected nodule candidates are classified as PFNs or non-PFNs. Supervised learning is used, where a classifier is

  1. Sensitivity and accuracy of volumetry of pulmonary nodules on low-dose 16- and 64-row multi-detector CT : an anthropomorphic phantom study

    NARCIS (Netherlands)

    Xie, X.; Zhao, Yingru; Snijder, R.A.; van Ooijen, P.M.; de Jong, P.A.; Oudkerk, M.; de Bock, G.H.; Vliegenthart, R.; Greuter, M.J.

    To assess the sensitivity of detection and accuracy of volumetry by manual and semi-automated quantification of artificial pulmonary nodules in an anthropomorphic thoracic phantom on low-dose CT. Fifteen artificial spherical nodules (diameter 3, 5, 8, 10 and 12 mm; CT densities -800, -630 and +100

  2. Ultralow dose CT for pulmonary nodule detection with chest X-ray equivalent dose - a prospective intra-individual comparative study

    Energy Technology Data Exchange (ETDEWEB)

    Messerli, Michael [University Zurich, Department of Nuclear Medicine, University Hospital Zurich, Zurich (Switzerland); Cantonal Hospital St. Gallen, Division of Radiology and Nuclear Medicine, St. Gallen (Switzerland); Kluckert, Thomas; Knitel, Meinhard; Desbiolles, Lotus; Bauer, Ralf W.; Wildermuth, Simon [Cantonal Hospital St. Gallen, Division of Radiology and Nuclear Medicine, St. Gallen (Switzerland); Waelti, Stephan [Cantonal Hospital St. Gallen, Division of Radiology and Nuclear Medicine, St. Gallen (Switzerland); University of Montreal, Department of Radiology, CHU Sainte-Justine, Montreal, Quebec (Canada); Rengier, Fabian [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology, Heidelberg (Germany); Warschkow, Rene [Cantonal Hospital St. Gallen, Department of Surgery, St. Gallen (Switzerland); Alkadhi, Hatem [University Zurich, Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Zurich (Switzerland); Leschka, Sebastian [Cantonal Hospital St. Gallen, Division of Radiology and Nuclear Medicine, St. Gallen (Switzerland); University Zurich, Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Zurich (Switzerland)

    2017-08-15

    To prospectively evaluate the accuracy of ultralow radiation dose CT of the chest with tin filtration at 100 kV for pulmonary nodule detection. 202 consecutive patients undergoing clinically indicated chest CT (standard dose, 1.8 ± 0.7 mSv) were prospectively included and additionally scanned with an ultralow dose protocol (0.13 ± 0.01 mSv). Standard dose CT was read in consensus by two board-certified radiologists to determine the presence of lung nodules and served as standard of reference (SOR). Two radiologists assessed the presence of lung nodules and their locations on ultralow dose CT. Sensitivity and specificity of the ultralow dose protocol was compared against the SOR, including subgroup analyses of different nodule sizes and types. A mixed effects logistic regression was used to test for independent predictors for sensitivity of pulmonary nodule detection. 425 nodules (mean diameter 3.7 ± 2.9 mm) were found on SOR. Overall sensitivity for nodule detection by ultralow dose CT was 91%. In multivariate analysis, nodule type, size and patients BMI were independent predictors for sensitivity (p < 0.001). Ultralow dose chest CT at 100 kV with spectral shaping enables a high sensitivity for the detection of pulmonary nodules at exposure levels comparable to plain film chest X-ray. (orig.)

  3. [Risk factor analysis of the patients with solitary pulmonary nodules and establishment of a prediction model for the probability of malignancy].

    Science.gov (United States)

    Wang, X; Xu, Y H; Du, Z Y; Qian, Y J; Xu, Z H; Chen, R; Shi, M H

    2018-02-23

    Objective: This study aims to analyze the relationship among the clinical features, radiologic characteristics and pathological diagnosis in patients with solitary pulmonary nodules, and establish a prediction model for the probability of malignancy. Methods: Clinical data of 372 patients with solitary pulmonary nodules who underwent surgical resection with definite postoperative pathological diagnosis were retrospectively analyzed. In these cases, we collected clinical and radiologic features including gender, age, smoking history, history of tumor, family history of cancer, the location of lesion, ground-glass opacity, maximum diameter, calcification, vessel convergence sign, vacuole sign, pleural indentation, speculation and lobulation. The cases were divided to modeling group (268 cases) and validation group (104 cases). A new prediction model was established by logistic regression analying the data from modeling group. Then the data of validation group was planned to validate the efficiency of the new model, and was compared with three classical models(Mayo model, VA model and LiYun model). With the calculated probability values for each model from validation group, SPSS 22.0 was used to draw the receiver operating characteristic curve, to assess the predictive value of this new model. Results: 112 benign SPNs and 156 malignant SPNs were included in modeling group. Multivariable logistic regression analysis showed that gender, age, history of tumor, ground -glass opacity, maximum diameter, and speculation were independent predictors of malignancy in patients with SPN( P prediction model for the probability of malignancy as follow: p =e(x)/(1+ e(x)), x=-4.8029-0.743×gender+ 0.057×age+ 1.306×history of tumor+ 1.305×ground-glass opacity+ 0.051×maximum diameter+ 1.043×speculation. When the data of validation group was added to the four-mathematical prediction model, The area under the curve of our mathematical prediction model was 0.742, which is greater

  4. Dual time-point FDG PET/CT for differentiating benign from ...

    African Journals Online (AJOL)

    Objective. Fluorodeoxyglucose (FDG)-positron emission tomography (PET) is an accurate non-invasive imaging test for differentiating benign from malignant solitary pulmonary nodules (SPNs). We aimed to assess its diagnostic accuracy for differentiating benign from malignant SPNs in a tuberculosis (TB)-endemic area.

  5. Application of positron emission tomography-computed tomography in the diagnosis of pulmonary ground-glass nodules.

    Science.gov (United States)

    Hu, Lili; Pan, Yuanwei; Zhou, Zhigang; Gao, Jianbo

    2017-11-01

    The aim of the present study was to investigate the value of positron emission tomography-computed tomography (PET-CT) using 18 F-fluorodeoxyglucose in the clinical diagnosis of pulmonary ground-glass nodule. In total, 54 patients with pulmonary GGN that were identified by PET-CT examination were selected and confirmed by pathology and clinical diagnosis in hospital between April 2014 and April 2015. The association between PET-CT findings and pathology, and the value of PET-CT were then evaluated. In the 54 patients, solitary pulmonary GGN with a nodule diameter of between 0.6 and 2.0 cm were detected. Amongst them, the PET-CT examination of 42 patients revealed hyper metabolic nodules, and were all mixed GGN type nodules with a diameter >1 cm. The PET-CT examination of the remaining 12 patients demonstrated no evidence of metabolic abnormalities and the nodules in these patients were pure or mixed GGN with a diameter <1 cm (except 2 cases with a diameter ≥1 cm). Furthermore, the diagnoses for all patients were pathologically confirmed by CT-guided needle biopsy or thoracoscopic surgical resection. Amongst them, there were 41 cases of lung adenocarcinoma, 4 cases of fungal infection, 7 cases of inflammation and 2 cases of adenomatoid hyperplasia. Additionally, PET-CT has a lower detection rate for smaller GGN exhibits no clear advantage for pure GGN, but has a higher detection rate for larger GGN. In conclusion, to a certain extent, PET-CT makes up for the shortcomings of traditional imaging and has some clinical value for the diagnosis of GGN.

  6. Effect of Scanning and Reconstruction Parameters on Three Dimensional Volume and CT Value Measurement of Pulmonary Nodules: A Phantom Study

    Directory of Open Access Journals (Sweden)

    Datong SU

    2017-08-01

    Full Text Available Background and objective The computed tomography (CT follow-up of indeterminate pulmonary nodules aiming to evaluate the change of the volume and CT value is the common strategy in clinic. The CT dose needs to considered on serious CT scans in addition to the measurement accuracy. The purpose of this study is to quantify the precision of pulmonary nodule volumetric measurement and CT value measurement with various tube currents and reconstruction algorithms in a phantom study with dual-energy CT. Methods A chest phantom containing 9 artificial spherical solid nodules with known diameter (D=2.5 mm, 5 mm, 10 mm and density (-100 HU, 60 HU and 100 HU was scanned using a 64-row detector CT canner at 120 Kilovolt & various currents (10 mA, 20 mA, 50 mA, 80 mA,100 mA, 150 mA and 350 mA. Raw data were reconstructed with filtered back projection and three levels of adaptive statistical iterative reconstruction algorithm (FBP, ASIR; 30%, 50% and 80%. Automatic volumetric measurements were performed using commercially available software. The relative volume error (RVE and the absolute attenuation error (AAE between the software measures and the reference-standard were calculated. Analyses of the variance were performed to evaluate the effect of reconstruction methods, different scan parameters, nodule size and attenuation on the RPE. Results The software substantially overestimated the very small (D=2.5 mm nodule's volume [mean RVE: (100.8%±28%] and underestimated it attenuation [mean AAE: (-756±80 HU]. The mean RVEs of nodule with diameter as 5 mm and 10 mm were small [(-0.9%±1.1% vs (0.9%±1.4%], however, the mean AAEs [(-243±26 HU vs (-129±7 HU] were large. The ANOVA analysis for repeated measurements showed that different tube current and reconstruction algorithm had no significant effect on the volumetric measurements for nodules with diameter of 5 mm and 10 mm (F=5.60, P=0.10 vs F=11.13, P=0.08, but significant effects on the measurement of CT

  7. [Thyroid nodule].

    Science.gov (United States)

    Clerc, Jérôme

    2005-01-31

    The thyroid nodule is a frequent, most often benign, chronic, multifocal and slowly progressive disease. The first line strategy is to diagnose cancerous nodules (thyroid nodules is controversial since the prognosis of thyroid cancer is excellent for lesions measuring less than 20 mm. Though imaging accuracy is quite limited in assessing the diagnosis of thyroid cancer, both ultrasounds (US) and thyroid scan are helpful to enhance nodular identification (>30%), to sort the nodules relevant for cytological sampling and to optimize the follow-up, the major source of health costs. Suspicious and non contributive FNAs must have a control FNA within 6 months. Nodules with a non suspicious FNA (>85%) require long term follow-up. This follow-up is mainly morphological. New or evolutive nodules, as assessed by palpation or US, will require iterative FNAs or should be considered for surgery. In patients with hyperfunctioning nodules on the scan (10 to 20%), a yearly evaluation of the TSH level is sufficient. These nodules account either for autonomously functioning ones, which slowly develop towards thyrotoxicosis, or for hyperplastic nodules frequently disclosing a lymphocytic thyroiditis. Morbidity due to thyroid autonomy is still underestimated especially in aging patients with TSH levels thyroid nodule is suggested.

  8. Juxta-Vascular Pulmonary Nodule Segmentation in PET-CT Imaging Based on an LBF Active Contour Model with Information Entropy and Joint Vector

    Directory of Open Access Journals (Sweden)

    Rui Hao

    2018-01-01

    Full Text Available The accurate segmentation of pulmonary nodules is an important preprocessing step in computer-aided diagnoses of lung cancers. However, the existing segmentation methods may cause the problem of edge leakage and cannot segment juxta-vascular pulmonary nodules accurately. To address this problem, a novel automatic segmentation method based on an LBF active contour model with information entropy and joint vector is proposed in this paper. Our method extracts the interest area of pulmonary nodules by a standard uptake value (SUV in Positron Emission Tomography (PET images, and automatic threshold iteration is used to construct an initial contour roughly. The SUV information entropy and the gray-value joint vector of Positron Emission Tomography–Computed Tomography (PET-CT images are calculated to drive the evolution of contour curve. At the edge of pulmonary nodules, evolution will be stopped and accurate results of pulmonary nodule segmentation can be obtained. Experimental results show that our method can achieve 92.35% average dice similarity coefficient, 2.19 mm Hausdorff distance, and 3.33% false positive with the manual segmentation results. Compared with the existing methods, our proposed method that segments juxta-vascular pulmonary nodules in PET-CT images is more accurate and efficient.

  9. Value of a Computer-aided Detection System Based on Chest Tomosynthesis Imaging for the Detection of Pulmonary Nodules.

    Science.gov (United States)

    Yamada, Yoshitake; Shiomi, Eisuke; Hashimoto, Masahiro; Abe, Takayuki; Matsusako, Masaki; Saida, Yukihisa; Ogawa, Kenji

    2018-04-01

    Purpose To assess the value of a computer-aided detection (CAD) system for the detection of pulmonary nodules on chest tomosynthesis images. Materials and Methods Fifty patients with and 50 without pulmonary nodules underwent both chest tomosynthesis and multidetector computed tomography (CT) on the same day. Fifteen observers (five interns and residents, five chest radiologists, and five abdominal radiologists) independently evaluated tomosynthesis images of 100 patients for the presence of pulmonary nodules in a blinded and randomized manner, first without CAD, then with the inclusion of CAD marks. Multidetector CT images served as the reference standard. Free-response receiver operating characteristic analysis was used for the statistical analysis. Results The pooled diagnostic performance of 15 observers was significantly better with CAD than without CAD (figure of merit [FOM], 0.74 vs 0.71, respectively; P = .02). The average true-positive fraction and false-positive rate per all cases with CAD were 0.56 and 0.26, respectively, whereas those without CAD were 0.47 and 0.20, respectively. Subanalysis showed that the diagnostic performance of interns and residents was significantly better with CAD than without CAD (FOM, 0.70 vs 0.62, respectively; P = .001), whereas for chest radiologists and abdominal radiologists, the FOM with CAD values were greater but not significantly: 0.80 versus 0.78 (P = .38) and 0.74 versus 0.73 (P = .65), respectively. Conclusion CAD significantly improved diagnostic performance in the detection of pulmonary nodules on chest tomosynthesis images for interns and residents, but provided minimal benefit for chest radiologists and abdominal radiologists. © RSNA, 2017 Online supplemental material is available for this article.

  10. Electromagnetic Navigational Bronchoscopy versus CT-guided Percutaneous Sampling of Peripheral Indeterminate Pulmonary Nodules: A Cohort Study.

    Science.gov (United States)

    Bhatt, Kavita M; Tandon, Yasmeen K; Graham, Ruffin; Lau, Charles T; Lempel, Jason K; Azok, Joseph T; Mazzone, Peter J; Schneider, Erika; Obuchowski, Nancy A; Bolen, Michael A

    2018-03-01

    Purpose To compare the diagnostic yield and complication rates of electromagnetic navigational bronchoscopic (ENB)-guided and computed tomography (CT)-guided percutaneous tissue sampling of lung nodules. Materials and Methods Retrospectively identified were 149 patients sampled percutaneously with CT guidance and 146 patients who underwent ENB with transbronchial biopsy of a lung lesion between 2013 and 2015. Clinical data, incidence of complications, and nodule pathologic analyses were assessed through electronic medical record review. Lung nodule characteristics were reviewed through direct image analysis. Molecular marker studies and pathologic analyses from surgical excision were reviewed when available. Multiple-variable logistic regression models were built to compare the diagnostic yield and complication rates for each method and for different patient and disease characteristics. Results CT-guided sampling was more likely to be diagnostic than ENB-guided biopsy (86.0% [129 of 150] vs 66.0% [99 of 150], respectively), and this difference remained significant even after adjustments were made for patient and nodule characteristics (P guided sampling (P guided sampling, 88.9% [32 of 36]; CT-guided sampling, 82.0% [41 of 50]). The two groups had similar rates of major complications (symptomatic hemorrhage, P > .999; pneumothorax requiring chest tube and/or admission, P = .417). Conclusion CT-guided transthoracic biopsy provided higher diagnostic yield in the assessment of peripheral pulmonary nodules than navigational bronchoscopy with a similar rate of clinically relevant complications. © RSNA, 2017 Online supplemental material is available for this article.

  11. Influence of radiation dose and iterative reconstruction algorithms for measurement accuracy and reproducibility of pulmonary nodule volumetry: A phantom study

    International Nuclear Information System (INIS)

    Kim, Hyungjin; Park, Chang Min; Song, Yong Sub; Lee, Sang Min; Goo, Jin Mo

    2014-01-01

    Purpose: To evaluate the influence of radiation dose settings and reconstruction algorithms on the measurement accuracy and reproducibility of semi-automated pulmonary nodule volumetry. Materials and methods: CT scans were performed on a chest phantom containing various nodules (10 and 12 mm; +100, −630 and −800 HU) at 120 kVp with tube current–time settings of 10, 20, 50, and 100 mAs. Each CT was reconstructed using filtered back projection (FBP), iDose 4 and iterative model reconstruction (IMR). Semi-automated volumetry was performed by two radiologists using commercial volumetry software for nodules at each CT dataset. Noise, contrast-to-noise ratio and signal-to-noise ratio of CT images were also obtained. The absolute percentage measurement errors and differences were then calculated for volume and mass. The influence of radiation dose and reconstruction algorithm on measurement accuracy, reproducibility and objective image quality metrics was analyzed using generalized estimating equations. Results: Measurement accuracy and reproducibility of nodule volume and mass were not significantly associated with CT radiation dose settings or reconstruction algorithms (p > 0.05). Objective image quality metrics of CT images were superior in IMR than in FBP or iDose 4 at all radiation dose settings (p < 0.05). Conclusion: Semi-automated nodule volumetry can be applied to low- or ultralow-dose chest CT with usage of a novel iterative reconstruction algorithm without losing measurement accuracy and reproducibility

  12. Influence of radiation dose and iterative reconstruction algorithms for measurement accuracy and reproducibility of pulmonary nodule volumetry: A phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyungjin, E-mail: khj.snuh@gmail.com [Department of Radiology, Seoul National University College of Medicine, Institute of Radiation Medicine, Seoul National University Medical Research Center, 101, Daehangno, Jongno-gu, Seoul 110-744 (Korea, Republic of); Park, Chang Min, E-mail: cmpark@radiol.snu.ac.kr [Department of Radiology, Seoul National University College of Medicine, Institute of Radiation Medicine, Seoul National University Medical Research Center, 101, Daehangno, Jongno-gu, Seoul 110-744 (Korea, Republic of); Cancer Research Institute, Seoul National University, 101, Daehangno, Jongno-gu, Seoul 110-744 (Korea, Republic of); Song, Yong Sub, E-mail: terasong@gmail.com [Department of Radiology, Seoul National University College of Medicine, Institute of Radiation Medicine, Seoul National University Medical Research Center, 101, Daehangno, Jongno-gu, Seoul 110-744 (Korea, Republic of); Lee, Sang Min, E-mail: sangmin.lee.md@gmail.com [Department of Radiology, Seoul National University College of Medicine, Institute of Radiation Medicine, Seoul National University Medical Research Center, 101, Daehangno, Jongno-gu, Seoul 110-744 (Korea, Republic of); Goo, Jin Mo, E-mail: jmgoo@plaza.snu.ac.kr [Department of Radiology, Seoul National University College of Medicine, Institute of Radiation Medicine, Seoul National University Medical Research Center, 101, Daehangno, Jongno-gu, Seoul 110-744 (Korea, Republic of); Cancer Research Institute, Seoul National University, 101, Daehangno, Jongno-gu, Seoul 110-744 (Korea, Republic of)

    2014-05-15

    Purpose: To evaluate the influence of radiation dose settings and reconstruction algorithms on the measurement accuracy and reproducibility of semi-automated pulmonary nodule volumetry. Materials and methods: CT scans were performed on a chest phantom containing various nodules (10 and 12 mm; +100, −630 and −800 HU) at 120 kVp with tube current–time settings of 10, 20, 50, and 100 mAs. Each CT was reconstructed using filtered back projection (FBP), iDose{sup 4} and iterative model reconstruction (IMR). Semi-automated volumetry was performed by two radiologists using commercial volumetry software for nodules at each CT dataset. Noise, contrast-to-noise ratio and signal-to-noise ratio of CT images were also obtained. The absolute percentage measurement errors and differences were then calculated for volume and mass. The influence of radiation dose and reconstruction algorithm on measurement accuracy, reproducibility and objective image quality metrics was analyzed using generalized estimating equations. Results: Measurement accuracy and reproducibility of nodule volume and mass were not significantly associated with CT radiation dose settings or reconstruction algorithms (p > 0.05). Objective image quality metrics of CT images were superior in IMR than in FBP or iDose{sup 4} at all radiation dose settings (p < 0.05). Conclusion: Semi-automated nodule volumetry can be applied to low- or ultralow-dose chest CT with usage of a novel iterative reconstruction algorithm without losing measurement accuracy and reproducibility.

  13. Multidetector CT features of pulmonary focal ground-glass opacity: differences between benign and malignant

    Science.gov (United States)

    Fan, L; Liu, S-Y; Li, Q-C; Yu, H; Xiao, X-S

    2012-01-01

    Objective To evaluate different features between benign and malignant pulmonary focal ground-glass opacity (fGGO) on multidetector CT (MDCT). Methods 82 pathologically or clinically confirmed fGGOs were retrospectively analysed with regard to demographic data, lesion size and location, attenuation value and MDCT features including shape, margin, interface, internal characteristics and adjacent structure. Differences between benign and malignant fGGOs were analysed using a χ2 test, Fisher's exact test or Mann–Whitney U-test. Morphological characteristics were analysed by binary logistic regression analysis to estimate the likelihood of malignancy. Results There were 21 benign and 61 malignant lesions. No statistical differences were found between benign and malignant fGGOs in terms of demographic data, size, location and attenuation value. The frequency of lobulation (p=0.000), spiculation (p=0.008), spine-like process (p=0.004), well-defined but coarse interface (p=0.000), bronchus cut-off (p=0.003), other air-containing space (p=0.000), pleural indentation (p=0.000) and vascular convergence (p=0.006) was significantly higher in malignant fGGOs than that in benign fGGOs. Binary logistic regression analysis showed that lobulation, interface and pleural indentation were important indicators for malignant diagnosis of fGGO, with the corresponding odds ratios of 8.122, 3.139 and 9.076, respectively. In addition, a well-defined but coarse interface was the most important indicator of malignancy among all interface types. With all three important indicators considered, the diagnostic sensitivity, specificity and accuracy were 93.4%, 66.7% and 86.6%, respectively. Conclusion An fGGO with lobulation, a well-defined but coarse interface and pleural indentation gives a greater than average likelihood of being malignant. PMID:22128130

  14. Designing a new CAD system for pulmonary nodule detection in High Resolution Computed Tomography (HRCT images

    Directory of Open Access Journals (Sweden)

    Parsa Hosseini M

    2012-07-01

    Conclusion: Considering the complexity and different shapes of lung nodules and large number of CT images to evaluate, finding lung nodules are difficult and time consuming for physicians and include human error. Experimental results showed the accuracy of the proposed method to be appropriate (P<0.05 for lung nodule detection.

  15. Enhancement characteristics of benign and malignant focal peripheral nodules in the peripheral zone of the prostate gland studied using contrast-enhanced transrectal ultrasound

    International Nuclear Information System (INIS)

    Tang, J.; Yang, J.-C.; Luo, Y.; Li, J.; Li, Y.; Shi, H.

    2008-01-01

    Aim: To assess the value of contrast-enhanced grey-scale transrectal ultrasound (CETRUS) in predicting the nature of peripheral zone hypoechoic lesions of the prostate. Materials and Methods: Ninety-one patients with peripheral zone hypoechoic lesions on ultrasound were evaluated with CETRUS followed by lesion-specific and sextant transrectal ultrasound-guided biopsies. The enhancement patterns of the lesions were observed and graded subjectively using adjacent peripheral zone tissue as the reference. Time to enhancement (AT), time to peak intensity (TTP) and peak intensity (PI) were quantified within each nodule. Ultrasound findings were correlated with biopsy findings. Results: Transrectal ultrasound-guided biopsy of the hypoechoic lesions revealed prostate cancer in 44 patients and benign prostatic diseases in 47. The intensity of enhancement within the lesions were graded as no enhancement, increased, equal, or decreased compared with adjacent peripheral zone tissue in two, 30, five and seven in the prostate cancer group and 14, 15, four and 14 in the benign group, respectively. The difference was statistically significant (p < 0.05). The peak enhancement intensity was found to be the most optimal discriminatory parameter (area under curve AUC 0.70; 95% CI: 0.58, 0.82). Conclusion: Malignant hypoechoic nodules in the peripheral zone of the prostate are more likely to enhance early and more intensely on CETRUS. A non-enhanced hypoechoic peripheral zone lesion was more likely to be benign

  16. Can Lung Nodules Be Cancerous?

    Science.gov (United States)

    ... lung nodules be cancerous? Answers from Eric J. Olson, M.D. Yes, lung nodules can be cancerous, ... to determine if it's cancerous. With Eric J. Olson, M.D. AskMayoExpert. Pulmonary nodules. Rochester, Minn.: Mayo ...

  17. Solitary pulmonary nodules: cost-savings indicated by Australian experience with FDG-PET

    International Nuclear Information System (INIS)

    Keith, C.J.; Miles, K.A.; Pitman, A.G.; Hicks, R.J.

    2002-01-01

    Full text: To date, decision tree analyses demonstrating the cost-effectiveness of PET in Australia have been constrained by the need to use overseas values for diagnostic performance and disease prevalence. This study uses Australian PET experience to estimate the cost-savings produced by incorporation of FDG-PET into diagnostic algorithms for characterisation of solitary pulmonary nodules (SPNs). Values for disease prevalence and diagnostic accuracy of PET from a combined series of 89 SPNs from the Wesley Hospital and Peter MacCallum Cancer Institute were applied to two previously published decision tree models. Procedure costs were derived from the Medicare Benefits Schedule and DRG Cost Weights for Australian public hospitals. A cost of $1200 was assigned to PET. Sensitivity analyses evaluated the effect of disease prevalence and PET cost on the cost savings produced by each strategy. The values for disease prevalence (0.54), PET sensitivity (92%) and specificity (95%) from the combined series indicated cost savings per patient of $774 and $554 for the two decision trees. PET would remain cost-saving for values of prevalence up to 0.90 and 0.76, and PET costs of $1974 and $1967, for each model respectively. FDG-PET evaluation of SPNs would produce cost-savings within Australia even with substantial variations in disease prevalence and PET costs. Copyright (2002) Blackwell Science Pty Ltd

  18. Towards automatic pulmonary nodule management in lung cancer screening with deep learning.

    Science.gov (United States)

    Ciompi, Francesco; Chung, Kaman; van Riel, Sarah J; Setio, Arnaud Arindra Adiyoso; Gerke, Paul K; Jacobs, Colin; Scholten, Ernst Th; Schaefer-Prokop, Cornelia; Wille, Mathilde M W; Marchianò, Alfonso; Pastorino, Ugo; Prokop, Mathias; van Ginneken, Bram

    2017-04-19

    The introduction of lung cancer screening programs will produce an unprecedented amount of chest CT scans in the near future, which radiologists will have to read in order to decide on a patient follow-up strategy. According to the current guidelines, the workup of screen-detected nodules strongly relies on nodule size and nodule type. In this paper, we present a deep learning system based on multi-stream multi-scale convolutional networks, which automatically classifies all nodule types relevant for nodule workup. The system processes raw CT data containing a nodule without the need for any additional information such as nodule segmentation or nodule size and learns a representation of 3D data by analyzing an arbitrary number of 2D views of a given nodule. The deep learning system was trained with data from the Italian MILD screening trial and validated on an independent set of data from the Danish DLCST screening trial. We analyze the advantage of processing nodules at multiple scales with a multi-stream convolutional network architecture, and we show that the proposed deep learning system achieves performance at classifying nodule type that surpasses the one of classical machine learning approaches and is within the inter-observer variability among four experienced human observers.

  19. Pleural Dye Marking Using Radial Endobronchial Ultrasound and Virtual Bronchoscopy before Sublobar Pulmonary Resection for Small Peripheral Nodules.

    Science.gov (United States)

    Lachkar, Samy; Baste, Jean-Marc; Thiberville, Luc; Peillon, Christophe; Rinieri, Philippe; Piton, Nicolas; Guisier, Florian; Salaun, Mathieu

    2018-01-01

    Minimally invasive surgery of pulmonary nodules allows suboptimal palpation of the lung compared to open thoracotomy. The objective of this study was to assess endoscopic pleural dye marking using radial endobronchial ultrasound (r-EBUS) and virtual bronchoscopy to localize small peripheral lung nodules immediately before minimally invasive resection. The endoscopic procedure was performed without fluoroscopy, under general anesthesia in the operating room immediately before minimally invasive surgery. Then, 1 mL of methylene blue (0.5%) was instilled into the guide sheath, wedged in the subpleural space. Wedge resection or segmentectomy were guided by visualization of the dye on the pleural surface. Contribution of dye marking to the surgical procedure was rated by the surgeon. Twenty-five nodules, including 6 ground glass opacities, were resected in 22 patients by video-assisted thoracoscopic wedge resection (n = 11) or robotic-assisted thoracoscopic surgery (10 segmentectomies and 1 wedge resection). The median greatest diameter of nodules was 8 mm. No conversion to open thoracotomy was needed. The endoscopic procedure added an average 10 min to surgical resection. The dye was visible on the pleural surface in 24 cases. Histological diagnosis and free margin resection were obtained in all cases. Median skin-to-skin operating time was 90 min for robotic segmentectomy and 40 min for video-assisted wedge resection. The same operative precision was considered impossible by the surgeon without dye marking in 21 cases. Dye marking using r-EBUS and virtual bronchoscopy can be easily and safely performed to localize small pulmonary nodules immediately before minimally invasive resection. © 2018 S. Karger AG, Basel.

  20. The value of FDG-PET/CT in assessing single pulmonary nodules in patients at high risk of lung cancer

    International Nuclear Information System (INIS)

    Kagna, Olga; Solomonov, Anna; Fruchter, Oren; Keidar, Zohar; Bar-Shalom, Rachel; Israel, Ora; Yigla, Mordechai; Guralnik, Luda

    2009-01-01

    To evaluate whether PET/low-dose CT (ldCT) using 18 F-fluorodeoxyglucose (FDG) improves characterization of indeterminate single pulmonary nodules (SPNs) in patients at high risk of lung cancer. Retrospective analysis of 307 patients who underwent FDG-PET/CT for indeterminate SPNs identified 93 (70 men, age range 46-90 years) at high risk of lung cancer (age >40 years, minimum 10 pack-year smokers). SPNs were evaluated for the presence and intensity of FDG avidity and ldCT patterns. The performance of visual and semiquantitative FDG-PET/ldCT algorithms for characterization of SPNs was compared to that of ldCT. Incongruent FDG-PET and ldCT patterns were analyzed for significance in further patient management. Malignancy was diagnosed in 38% patients. FDG avidity defined 33 SPNs as true-positive (TP) and 2 as false-negative (FN) (malignant), and 41 as true-negative (TN) and 17 as false-positive (FP) (benign). For SUVmax of 2.2 (by ROC analysis) there were 27 TP, 8 FN, 48 TN and 10 FP SPNs. LdCT defined 34 TP, 1 FN, 28 TN and 30 FP lesions. Of the FP lesions on ldCT, 60% were FDG-negative. Visual PET/ldCT analysis had a sensitivity of 94%, a specificity of 70%, an accuracy of 80%, a positive predictive value (PPV) of 66%, and a negative predictive value (NPV) of 95% as compared to 77%, 83%, 81%, 73%, 86% for semiquantitative PET/ldCT and 97%, 48%, 66%, 53%, 96% for ldCT, respectively. Both PET/ldCT algorithms had statistically significantly higher specificity and accuracy than ldCT. Semiquantitative analysis showed significantly higher PPV and lower sensitivity and NPV than found with ldCT. A single screening procedure encompassing FDG-PET and ldCT may improve screening for lung cancer in high-risk patients. The significantly improved specificity may potentially reduce FP ldCT results and further unnecessary invasive procedures. (orig.)

  1. Invasive procedure for clarification of pulmonary nodules; Invasive Verfahren zur Abklaerung pulmonaler Rundherde

    Energy Technology Data Exchange (ETDEWEB)

    Mahnken, A.H. [Universitaetsklinikum, Philipps-Universitaet Marburg, Klinik fuer Diagnostische und Interventionelle Radiologie, Marburg (Germany)

    2014-05-15

    The management of solitary lung nodules poses a common clinical problem and biopsy is often required. Several guidelines provide slightly different recommendations and there are no uniform recommendations regarding the ideal technique of puncture guidance (e.g. percutaneous versus bronchoscopic or thoracoscopic). Fine needle aspiration biopsy (FNA) and core biopsy are well established techniques. Both can be performed under CT and to some extent ultrasound guidance. Diagnostic accuracies of FNA and core biopsy for malignant lesions are around 95 %. Core biopsy is superior to FNA for establishing a specific diagnosis with a diagnostic yield of 81-88 % versus 17-21 %. In clinical routine practice core biopsy is the superior tool when compared to FNA. Central lesions in close proximity to bronchi may be biopsied with endobronchial ultrasound (EBUS)-guided bronchoscopy. In all other lesions percutaneous, ideally CT-guided biopsy should be the method of first choice. (orig.) [German] Solitaere Lungenrundherde stellen ein haeufiges differenzialdiagnostisches Problem dar, das oftmals mit der Bildgebung alleine nicht endgueltig zu loesen ist und eine Biopsie erfordert. Die Indikation zur Biopsie variiert zwischen den Leitlinien, und die beste Technik der Biopsie (perkutan vs. bronchoskopisch vs. thorakoskopisch) ist oftmals nicht eindeutig. Feinnadelaspirations- (FNA) und Stanzbiopsie stehen als lange etablierte Standardtechniken zur Verfuegung. Beide koennen CT- und bedingt ultraschallgesteuert durchgefuehrt werden. Die diagnostische Aussagekraft fuer die Diagnose maligner Tumoren liegt fuer beide Techniken bei 95 %. Die Stanzbiopsie ist jedoch der FNA fuer die spezifische Diagnose benigner Prozesse mit einer Genauigkeit von 82-88 vs. 17-21 % ueberlegen. Die Stanzbiopsie ist gegenueber der FNA das in der klinischen Routine ueberlegene Werkzeug. Bei sehr zentralen Herden in Nachbarschaft zu einem Bronchus kann primaer eine bronchoskopische EBUS-gesteuerte (endobronchialer

  2. Three-dimensional Mass Measurement of Subsolid Pulmonary Nodules on Chest CT: Intra and Inter-observer Variability

    Directory of Open Access Journals (Sweden)

    Huiting LIU

    2015-05-01

    Full Text Available Background and objective Subsolid pulmonary nodules tend to exhibit considerably slower growth rates than solid lesions, nevertheless, higher malignancy probability. The diagnosis of indeterminate nodules largely depends on the growth evaluation during follow-up. The growth can manifested as an increase in size or the appearance and/or subsequent increase of solid components. The mass reflect the product of volume and density and can be more sensitive in growth evaluation. However, the repeatability needs a further validation. The purpose of this study is to assess the intra and inter-observer variability of mass measurement for subsolid nodules. Methods 80 subsolid nodules in 44 patients were retrospectively enrolled. Both the volume and mass were measured by two radiologists using blind method independently. Intra-observer and inter-observer variability were analyzed and compared by Bland-Altman method intra-class correlation test and Wilcoxon test. Results Software achieved satisfied segmentation for 92.5% nodules. Of them, 35% underwent manual modification. The 95% limits of agreement for intra-observer variability were -11.5%-10.4% for mass and -8.4%-8.8% for volume. The 95% limits of agreement for inter-observer variability were -17.4%-19.3% for mass and -17.9%-19.4% for volume.The intra-class correlation foefficients between volume and mass measument was 0.95 and 0.93 (both P<0.001 and no significant differences (P=0.78, 0.09 was found for intra- and inter-observer variability. Manual modification of the segmentation caused the worse mass measurement repeatability in spite of the reader satisfaction. Conclusion The repeatability of mass measurement has no significant difference with that of volume measurement and may act as a reliable method in the follow-up of subsolid nodules.

  3. Influence of the in-plane artefact in chest tomosynthesis on pulmonary nodule size measurements

    International Nuclear Information System (INIS)

    Soederman, Christina; Allansdotter Johnsson, Aase; Vikgren, Jenny; Rossi Norrlund, Rauni; Molnar, David; Svalkvist, Angelica; Maansson, Lars Gunnar; Baath, Magnus

    2016-01-01

    The aim of the present study was to investigate how the in-plane artefact present in the scan direction around structures in tomosynthesis images should be managed when measuring the size of nodules in chest tomosynthesis images in order to achieve acceptable measurement accuracy. Data from measurements, performed by radiologists, of the longest diameter of artificial nodules inserted in chest tomosynthesis images were used. The association between the measurement error and the direction of the longest nodule diameter, relative to the scan direction, was evaluated using the Kendall rank correlation coefficient. All of the radiologists had chosen to not include the artefact in the measurements. Significant association between measurement error and the direction of the longest diameter was found for nodules larger than 12 mm, which indicates that, for these nodules, there is a risk of underestimating the nodule size if the in-plane artefact is omitted from manual diameter measurements. (authors)

  4. Comparison of multi-slice CT findings between malignant focal pulmonary ground-glass opacity nodules and solid nodules of 3 cm or less

    International Nuclear Information System (INIS)

    Fan Li; Yu Hong; Liu Shiyuan; Li Qingchu; Jiang Tao; Xiao Xiangsheng

    2010-01-01

    Objective: To compare the MSCT findings of malignant focal pulmonary ground-glass opacity nodules (fGGO) and solid nodules of 3 cm or less, and try to find specific signs in fGGO. Methods: Clinical data (sex ratio, age), size of lesion and MSCT findings (shape, margin, interface, internal characteristics, adjacent structure) of 105 cases pathologically confirmed to have solid lung cancers and 48 cases with fGGO less than 3 cm were retrospectively analyzed. Differences were analyzed by using the Fisher exact test or Mann-Whitney U test. Results: The male and female ratio of solid lung cancer(60:45) were higher than that of fGGO (18:30, X 2 value 5.09, P 2 values were 11.48, 4.07, 29.70 and 22.38 respectively, P 2 values 1.00, 2.20, 0.00, 0.15, 4.43, 1.50, 0.00, P>0.05). Conclusions: Malignant fGGO and solid lung cancer manifest mostly similar MSCT features. The frequency of irregular shape, vacuole sign and air bronchograms was higher in fGGO than in solid lung cancer to some degree, but speculation is more infrequent in fGGO, which may be attribute to thepathological type and basis of tumor. (authors)

  5. Hard-copy versus soft-copy with and without simple image manipulation for detection of pulmonary nodules and masses

    International Nuclear Information System (INIS)

    Kosuda, S.; Kaji, T.; Iwasaki, Y.; Kusano, S.; Kobayashi, H.; Watanabe, M.

    2000-01-01

    To compare interpretation performance on soft-copy presentations, with and without simple image manipulation, and on unmodified hard-copy presentations with regard to detection of pulmonary nodules and masses. Material and Methods: Fifty chest digital radiograph combinations of patients with a total of 60 nodules, 32 of which were 2.0 cm in diameter, were selected for the study. Three readers evaluated three separate image formats: unmodified hard- and soft-copies, and soft-copies with simple image manipulation of lung and mediastinum window settings, and zooming. The screen display was 1600x1200 pixels with 8 bits/pixel. Results: The sensitivity, accuracy, detectability, and Az value of the soft-copy systems were clearly inferior to hard-copy evaluation. The mean Az values were 0.921 for unmodified hard-copy, 0.820 for image-manipulated soft-copy, and 0.781 for unmodified soft-copy. Conclusion: Soft-copy interpretations were not as sensitive in detecting pulmonary nodules and masses as hard-copy evaluation

  6. Influence of radiation dose and iterative reconstruction algorithms for measurement accuracy and reproducibility of pulmonary nodule volumetry: A phantom study.

    Science.gov (United States)

    Kim, Hyungjin; Park, Chang Min; Song, Yong Sub; Lee, Sang Min; Goo, Jin Mo

    2014-05-01

    To evaluate the influence of radiation dose settings and reconstruction algorithms on the measurement accuracy and reproducibility of semi-automated pulmonary nodule volumetry. CT scans were performed on a chest phantom containing various nodules (10 and 12mm; +100, -630 and -800HU) at 120kVp with tube current-time settings of 10, 20, 50, and 100mAs. Each CT was reconstructed using filtered back projection (FBP), iDose(4) and iterative model reconstruction (IMR). Semi-automated volumetry was performed by two radiologists using commercial volumetry software for nodules at each CT dataset. Noise, contrast-to-noise ratio and signal-to-noise ratio of CT images were also obtained. The absolute percentage measurement errors and differences were then calculated for volume and mass. The influence of radiation dose and reconstruction algorithm on measurement accuracy, reproducibility and objective image quality metrics was analyzed using generalized estimating equations. Measurement accuracy and reproducibility of nodule volume and mass were not significantly associated with CT radiation dose settings or reconstruction algorithms (p>0.05). Objective image quality metrics of CT images were superior in IMR than in FBP or iDose(4) at all radiation dose settings (pvolumetry can be applied to low- or ultralow-dose chest CT with usage of a novel iterative reconstruction algorithm without losing measurement accuracy and reproducibility. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  7. Effect of the high-pitch mode in dual-source computed tomography on the accuracy of three-dimensional volumetry of solid pulmonary nodules: A phantom study

    International Nuclear Information System (INIS)

    Hwang, Sung Ho; Oh, Yu Whan; Ham, Soo Youn; Kang, Eun Young; Lee, Ki Yeol

    2015-01-01

    To evaluate the influence of high-pitch mode (HPM) in dual-source computed tomography (DSCT) on the accuracy of three-dimensional (3D) volumetry for solid pulmonary nodules. A lung phantom implanted with 45 solid pulmonary nodules (n = 15 for each of 4-mm, 6-mm, and 8-mm in diameter) was scanned twice, first in conventional pitch mode (CPM) and then in HPM using DSCT. The relative percentage volume errors (RPEs) of 3D volumetry were compared between the HPM and CPM. In addition, the intermode volume variability (IVV) of 3D volumetry was calculated. In the measurement of the 6-mm and 8-mm nodules, there was no significant difference in RPE (p > 0.05, respectively) between the CPM and HPM (IVVs of 1.2 +/- 0.9%, and 1.7 +/- 1.5%, respectively). In the measurement of the 4-mm nodules, the mean RPE in the HPM (35.1 +/- 7.4%) was significantly greater (p < 0.01) than that in the CPM (18.4 +/- 5.3%), with an IVV of 13.1 +/- 6.6%. However, the IVVs were in an acceptable range (< 25%), regardless of nodule size. The accuracy of 3D volumetry with HPM for solid pulmonary nodule is comparable to that with CPM. However, the use of HPM may adversely affect the accuracy of 3D volumetry for smaller (< 5 mm in diameter) nodule.

  8. Effect of the high-pitch mode in dual-source computed tomography on the accuracy of three-dimensional volumetry of solid pulmonary nodules: A phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Sung Ho; Oh, Yu Whan; Ham, Soo Youn [Dept. of Radiology, Korea University Anam Hospital, Seoul (Korea, Republic of); Kang, Eun Young [Dept. of Radiology, Korea University Guro Hospital, Seoul (Korea, Republic of); Lee, Ki Yeol [Dept. of Radiology, Korea University Ansan Hospital, Ansan (Korea, Republic of)

    2015-06-15

    To evaluate the influence of high-pitch mode (HPM) in dual-source computed tomography (DSCT) on the accuracy of three-dimensional (3D) volumetry for solid pulmonary nodules. A lung phantom implanted with 45 solid pulmonary nodules (n = 15 for each of 4-mm, 6-mm, and 8-mm in diameter) was scanned twice, first in conventional pitch mode (CPM) and then in HPM using DSCT. The relative percentage volume errors (RPEs) of 3D volumetry were compared between the HPM and CPM. In addition, the intermode volume variability (IVV) of 3D volumetry was calculated. In the measurement of the 6-mm and 8-mm nodules, there was no significant difference in RPE (p > 0.05, respectively) between the CPM and HPM (IVVs of 1.2 +/- 0.9%, and 1.7 +/- 1.5%, respectively). In the measurement of the 4-mm nodules, the mean RPE in the HPM (35.1 +/- 7.4%) was significantly greater (p < 0.01) than that in the CPM (18.4 +/- 5.3%), with an IVV of 13.1 +/- 6.6%. However, the IVVs were in an acceptable range (< 25%), regardless of nodule size. The accuracy of 3D volumetry with HPM for solid pulmonary nodule is comparable to that with CPM. However, the use of HPM may adversely affect the accuracy of 3D volumetry for smaller (< 5 mm in diameter) nodule.

  9. Diffusion-weighted MR-imaging for the detection of pulmonary nodules at 1.5 Tesla: intraindividual comparison with multidetector computed tomography

    International Nuclear Information System (INIS)

    Regier, Marc; Schwarz, Dorothee; Henes, Frank Oliver; Groth, Michael; Begemann, Philipp G.C.; Adam, Gerhard; Kooijman, Hendrik

    2011-01-01

    To investigate the feasibility of diffusion-weighted imaging (DWI) MRI for detecting pulmonary nodules at 1.5 Tesla in comparison with standard multidetector computed tomography (MDCT). Twenty patients with disseminated cancer disease in which MDCT had assured the presence of at least one pulmonary nodule were examined using a respiratory-gated DWI MR-sequence. Grey scale inverted source images and coronal maximum intensity projection (MIP) images were consensually analysed by two experienced radiologists. Size and location of any nodule detected were assessed. Additionally, the readers evaluated each hemithorax for the presence of at least one nodule and applied a four-point conspicuity scale (1-hemithorax definitely affected; 4-hemithorax definitely not affected). MDCT data served as reference. At MDCT, a total of 71 pulmonary noduIes was found (size 3–5 mm, n = 16; 6–9 mm, n = 22; ≥10 mm, n = 33). For the DWI MR-sequence, a sensitivity of 86.4% was calculated for nodules ranging 6–9 mm and 97% for nodules ≥10 mm. In contrast, only 43.8% of lesions ≤5 mm was detected. The separate analysis of each hemithorax for the presence of at least one pulmonary nodule revealed a specificity rate, PPV and NPV of DWI-MR of 92.3%, 96% and 80%, respectively. The presented study is the first to confirm the diagnostic potential of DWI-MR in the detection of solid lung nodules. This technique allows for the detection of nodules ≥6 mm with reasonably high sensitivity rates (>86%). The observation of false positive findings decreases the accuracy of this approach compared with MDCT.

  10. Detection of small pulmonary nodules on chest radiographs: efficacy of dual-energy subtraction technique using flat-panel detector chest radiography

    International Nuclear Information System (INIS)

    Oda, S.; Awai, K.; Funama, Y.; Utsunomiya, D.; Yanaga, Y.; Kawanaka, K.; Nakaura, T.; Hirai, T.; Murakami, R.; Nomori, H.; Yamashita, Y.

    2010-01-01

    Aim: To investigate the effect of a double-exposure dual-energy subtraction (DES) technique on the diagnostic performance of radiologists detecting small pulmonary nodules on flat-panel detector (FPD) chest radiographs. Materials and methods: Using FPD radiography 41 sets of chest radiographs were obtained from 26 patients with pulmonary nodules measuring ≤20 mm and from 15 normal participants. Each dataset included standard and corresponding DES images. There were six non-solid, 10 part-solid, and 10 solid nodules. The mean size of the 26 nodules was 15 ± 4.8 mm. Receiver operating characteristic (ROC) analysis was performed to compare the performance of the eight board-certified radiologists. Results: For the eight radiologists, the mean value of the area under the ROC curve (AUC) without and with DES images was 0.62 ± 0.05 and 0.68 ± 0.05, respectively; the difference was statistically significant (p = 0.02). For part-solid nodules, the difference of the mean AUC value was statistically significant (AUC = 0.61 ± 0.07 versus 0.69 ± 0.05; p < 0.01); for non-solid nodules it was not (AUC = 0.62 ± 0.1 versus 0.61 ± 0.09; p = 0.73), and for solid nodules it was not (AUC = 0.75 ± 0.1 versus 0.78 ± 0.08; p = 0.23). For nodules with overlapping bone shadows, the difference of the mean AUC value was statistically significant (p = 0.03), for nodules without overlapping, it was not (p = 0.26). Conclusion: Use of a double-exposure DES technique at FPD chest radiography significantly improved the diagnostic performance of radiologists to detect small pulmonary nodules.

  11. Gold standards and expert panels: a pulmonary nodule case study with challenges and solutions

    Science.gov (United States)

    Miller, Dave P.; O'Shaughnessy, Kathryn F.; Wood, Susan A.; Castellino, Ronald A.

    2004-05-01

    Comparative evaluations of reader performance using different modalities, e.g. CT with computer-aided detection (CAD) vs. CT without CAD, generally require a "truth" definition based on a gold standard. There are many situations in which a true invariant gold standard is impractical or impossible to obtain. For instance, small pulmonary nodules are generally not assessed by biopsy or resection. In such cases, it is common to use a unanimous consensus or majority agreement from an expert panel as a reference standard for actionability in lieu of the unknown gold standard for disease. Nonetheless, there are three major concerns about expert panel reference standards: (1) actionability is not synonymous with disease (2) it may be possible to obtain different conclusions about which modality is better using different rules (e.g. majority vs. unanimous consensus), and (3) the variability associated with the panelists is not formally captured in the p-values or confidence intervals that are generally produced for estimating the extent to which one modality is superior to the other. A multi-reader-multi-case (MRMC) receiver operating characteristic (ROC) study was performed using 90 cases, 15 readers, and a reference truth based on 3 experienced panelists. The primary analyses were conducted using a reference truth of unanimous consensus regarding actionability (3 out of 3 panelists). To assess the three concerns noted above: (1) additional data from the original radiology reports were compared to the panel (2) the complete analysis was repeated using different definitions of truth, and (3) bootstrap analyses were conducted in which new truth panels were constructed by picking 1, 2, or 3 panelists at random. The definition of the reference truth affected the results for each modality (CT with CAD and CT without CAD) considered by itself, but the effects were similar, so the primary analysis comparing the modalities was robust to the choice of the reference truth.

  12. CT fluoroscopy guided transpleural cutting needle biopsy of small ({<=}2.5 cm) subpleural pulmonary nodules

    Energy Technology Data Exchange (ETDEWEB)

    Prosch, Helmut; Oschatz, Elisabeth; Eisenhuber, Edith; Wohlschlager, Helmut [Otto Wagner Hospital, Department of Radiology, Sanatoriumsstrasse 2, 1140 Vienna (Austria); Mostbeck, Gerhard H., E-mail: gerhard.mostbeck@wienkav.at [Otto Wagner Hospital, Department of Radiology, Sanatoriumsstrasse 2, 1140 Vienna (Austria)

    2011-01-15

    Purpose: Small subpleural pulmonary lesions are difficult to biopsy. While the direct, short needle path has been reported to have a lower rate of pneumothorax, the indirect path provides a higher diagnostic yield. Therefore, we tried to optimize the needle pathway and minimize the iatrogenic pneumothorax risk by evaluating a CT fluoroscopy guided direct approach to biopsy subpleural lesions. Material and methods: Between 01/2005 and 01/2007, CT fluoroscopy guided core biopsies were performed in 24 patients. Using our technique, the tip of the guide needle remains outside the visceral pleura (17 G coaxial guide needle, 18 G Biopsy-gun, 15 or 22 mm needle path). The position of the lesion relative to the needle tip can be optimized using CT fluoroscopy by adjusting the breathing position of the patient. The Biopty gun is fired with the needle tip still outside the pleural space. Cytological smears are analyzed by a cytopathologist on-site, and biopsies are repeated as indicated with the coaxial needle still outside the pleura. Results: Median nodule size was 1.6 cm (0.7-2.3 cm). A definitive diagnosis was obtained in 22 patients by histology and/or cytology. In one patient, only necrotic material could be obtained. In another patient, the intervention had to be aborted as the dyspnoic patient could not follow breathing instructions. An asymptomatic pneumothorax was present in seven patients; chest tube placement was not required. Conclusion: The presented biopsy approach has a high diagnostic yield and is especially advantageous for biopsies of small subpleural lesions in the lower lobes.

  13. Spontaneous regression of multiple pulmonary metastatic nodules of hepatocarcinoma: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Bahk, Yong Whee; Park, Seog Hee; Kim, Sun Moo [St. Mary' s Hospital, Catholic Medical College, Seoul (Korea, Republic of)

    1981-09-15

    Although are spontaneous regression of either primary or metastatic malignant tumor in the absence of or inadequate therapy has been well documented. Since the earliest day of this century various malignant tumors have been reported to spontaneously disappear or to be arrested of their growth, but the cases of hepatocarcinoma has been very rare. From the literature, we were able to find out 5 previously reported cases of hepatocarcinoma which showed spontaneous regression at the primary site. Recently we have seen a case of multiple pulmonary metastatic nodules of hepatocarcinoma which completely regressed spontaneously and this forms the basis of the present case report. The patient was 55-year-old male admitted to St. Mary's Hospital, Catholic Medical College because of a hard palpable mass in the epigastrium on April 26, 1978. The admission PA chest roentgenogram revealed multiple small nodular densities scattered throughout both lung field especially in lower zones and toward the peripheral portion. A hepatoscintigram revealed a large cold area involving the left lobe and inermediate zone of the liver. Alfa-fetoprotein and hepatitis B serum antigen test were positive whereas many other standard liver function tests turned out to be negative. A needle biopsy of the tumor revealed well differentiated hepatocellular carcinoma. The patient was put under chemotherapy which consisted of 5 FU 500 mg intravenously for 6 days from April 28 to May 3, 1978. The patient was discharged after this single course of 5 FU treatment and was on a herb medicine, the nature and quantity of which obscure. No other specific treatment was given. The second admission took place on Dec. 3, 1980 because of irregularity in bowel habits and dyspepsia. A follow up PA chest roentgenogram obtained on the second admission revealed complete disappearance of previously noted multiple pulmonary nodular lesions (Fig. 3). Follow up liver scan revealed persistence of the cold area in the left lobe

  14. Spontaneous regression of multiple pulmonary metastatic nodules of hepatocarcinoma: a case report

    International Nuclear Information System (INIS)

    Bahk, Yong Whee; Park, Seog Hee; Kim, Sun Moo

    1981-01-01

    Although are spontaneous regression of either primary or metastatic malignant tumor in the absence of or inadequate therapy has been well documented. Since the earliest day of this century various malignant tumors have been reported to spontaneously disappear or to be arrested of their growth, but the cases of hepatocarcinoma has been very rare. From the literature, we were able to find out 5 previously reported cases of hepatocarcinoma which showed spontaneous regression at the primary site. Recently we have seen a case of multiple pulmonary metastatic nodules of hepatocarcinoma which completely regressed spontaneously and this forms the basis of the present case report. The patient was 55-year-old male admitted to St. Mary's Hospital, Catholic Medical College because of a hard palpable mass in the epigastrium on April 26, 1978. The admission PA chest roentgenogram revealed multiple small nodular densities scattered throughout both lung field especially in lower zones and toward the peripheral portion. A hepatoscintigram revealed a large cold area involving the left lobe and inermediate zone of the liver. Alfa-fetoprotein and hepatitis B serum antigen test were positive whereas many other standard liver function tests turned out to be negative. A needle biopsy of the tumor revealed well differentiated hepatocellular carcinoma. The patient was put under chemotherapy which consisted of 5 FU 500 mg intravenously for 6 days from April 28 to May 3, 1978. The patient was discharged after this single course of 5 FU treatment and was on a herb medicine, the nature and quantity of which obscure. No other specific treatment was given. The second admission took place on Dec. 3, 1980 because of irregularity in bowel habits and dyspepsia. A follow up PA chest roentgenogram obtained on the second admission revealed complete disappearance of previously noted multiple pulmonary nodular lesions (Fig. 3). Follow up liver scan revealed persistence of the cold area in the left lobe

  15. Pulmonary emphysema is a predictor of pneumothorax after CT-guided transthoracic pulmonary biopsies of pulmonary nodules.

    Science.gov (United States)

    Lendeckel, Derik; Kromrey, Marie-Luise; Ittermann, Till; Schäfer, Sophia; Mensel, Birger; Kühn, Jens-Peter

    2017-01-01

    Pneumothoraces are the most frequently occurring complications of CT-guided percutaneous transthoracic pulmonary biopsies (PTPB). The aim of this study was to evaluate the influence of pre-diagnostic lung emphysema on the incidence and extent of pneumothoraces and to establish a risk stratification for the evaluation of the pre-procedure complication probability. CT-guided PTPB of 100 pre-selected patients (mean age 67.1±12.8 years) were retrospectively enrolled from a single center database of 235 PTPB performed between 2012-2014. Patients were grouped according to pneumothorax appearance directly after PTPB (group I: without pneumothorax, n = 50; group II: with pneumothorax, n = 50). Group II was further divided according to post-interventional treatment (group IIa: chest tube placement, n = 24; group IIb: conservative therapy, n = 26). For each patient pre-diagnostic percentage of emphysema was quantified using CT density analysis. Emphysema stages were compared between groups using bivariate analyses and multinomial logistic regression analyses. Emphysema percentage was significantly associated with the occurrence of post-interventional pneumothorax (p = 0.006). Adjusted for potential confounders (age, gender, lesion size and length of interventional pathway) the study yielded an OR of 1.07 (p = 0.042). Absolute risk of pneumothorax increased from 43.4% at an emphysema rate of 5% to 73.8% at 25%. No differences could be seen in patients with pneumothorax between percentage of emphysema and mode of therapy (p = 0.721). The rate of lung emphysema is proportionally related to the incidence of pneumothorax after CT-guided PTPB and allows pre-interventional risk stratification. There is no association between stage of emphysema and post-interventional requirement of chest tube placement.

  16. Computer-aided diagnosis for classifying benign versus malignant thyroid nodules based on ultrasound images: A comparison with radiologist-based assessments

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Yongjun [School of Electrical Engineering, Korea Advanced Institute of Science and Technology, 291, Daehak-ro, Yuseong-gu, Daejeon 34141 (Korea, Republic of); Paul, Anjan Kumar [Funzin, Inc., 148 Ankuk-dong, Jongro-gu, Seoul 03060 (Korea, Republic of); Kim, Namkug, E-mail: namkugkim@gmail.com; Baek, Jung Hwan; Choi, Young Jun [Department of Radiology, University of Ulsan College of Medicine, 388-1 Pungnap2-dong, Songpa-gu, Seoul 05505 (Korea, Republic of); Ha, Eun Ju [Department of Radiology, Ajou University School of Medicine, Wonchon-Dong, Yeongtong-Gu, Suwon 16499 (Korea, Republic of); Lee, Kang Dae; Lee, Hyoung Shin [Department of Otolaryngology Head and Neck Surgery, Kosin University College of Medicine, 34 Amnamdong, Seu-Gu, Busan 49267 (Korea, Republic of); Shin, DaeSeock; Kim, Nakyoung [MIDAS Information Technology, Pangyo-ro 228, Bundang-gu, Seongnam-si, Gyeonggi 13487 (Korea, Republic of)

    2016-01-15

    Purpose: To develop a semiautomated computer-aided diagnosis (CAD) system for thyroid cancer using two-dimensional ultrasound images that can be used to yield a second opinion in the clinic to differentiate malignant and benign lesions. Methods: A total of 118 ultrasound images that included axial and longitudinal images from patients with biopsy-confirmed malignant (n = 30) and benign (n = 29) nodules were collected. Thyroid CAD software was developed to extract quantitative features from these images based on thyroid nodule segmentation in which adaptive diffusion flow for active contours was used. Various features, including histogram, intensity differences, elliptical fit, gray-level co-occurrence matrixes, and gray-level run-length matrixes, were evaluated for each region imaged. Based on these imaging features, a support vector machine (SVM) classifier was used to differentiate benign and malignant nodules. Leave-one-out cross-validation with sequential forward feature selection was performed to evaluate the overall accuracy of this method. Additionally, analyses with contingency tables and receiver operating characteristic (ROC) curves were performed to compare the performance of CAD with visual inspection by expert radiologists based on established gold standards. Results: Most univariate features for this proposed CAD system attained accuracies that ranged from 78.0% to 83.1%. When optimal SVM parameters that were established using a grid search method with features that radiologists use for visual inspection were employed, the authors could attain rates of accuracy that ranged from 72.9% to 84.7%. Using leave-one-out cross-validation results in a multivariate analysis of various features, the highest accuracy achieved using the proposed CAD system was 98.3%, whereas visual inspection by radiologists reached 94.9% accuracy. To obtain the highest accuracies, “axial ratio” and “max probability” in axial images were most frequently included in the

  17. Observer training for computer-aided detection of pulmonary nodules in chest radiography

    NARCIS (Netherlands)

    de Boo, Diederick W.; van Hoorn, François; van Schuppen, Joost; Schijf, Laura; Scheerder, Maeke J.; Freling, Nicole J.; Mets, Onno; Weber, Michael; Schaefer-Prokop, Cornelia M.

    2012-01-01

    To assess whether short-term feedback helps readers to increase their performance using computer-aided detection (CAD) for nodule detection in chest radiography. The 140 CXRs (56 with a solitary CT-proven nodules and 84 negative controls) were divided into four subsets of 35; each were read in a

  18. Cloud-Based NoSQL Open Database of Pulmonary Nodules for Computer-Aided Lung Cancer Diagnosis and Reproducible Research.

    Science.gov (United States)

    Ferreira Junior, José Raniery; Oliveira, Marcelo Costa; de Azevedo-Marques, Paulo Mazzoncini

    2016-12-01

    Lung cancer is the leading cause of cancer-related deaths in the world, and its main manifestation is pulmonary nodules. Detection and classification of pulmonary nodules are challenging tasks that must be done by qualified specialists, but image interpretation errors make those tasks difficult. In order to aid radiologists on those hard tasks, it is important to integrate the computer-based tools with the lesion detection, pathology diagnosis, and image interpretation processes. However, computer-aided diagnosis research faces the problem of not having enough shared medical reference data for the development, testing, and evaluation of computational methods for diagnosis. In order to minimize this problem, this paper presents a public nonrelational document-oriented cloud-based database of pulmonary nodules characterized by 3D texture attributes, identified by experienced radiologists and classified in nine different subjective characteristics by the same specialists. Our goal with the development of this database is to improve computer-aided lung cancer diagnosis and pulmonary nodule detection and classification research through the deployment of this database in a cloud Database as a Service framework. Pulmonary nodule data was provided by the Lung Image Database Consortium and Image Database Resource Initiative (LIDC-IDRI), image descriptors were acquired by a volumetric texture analysis, and database schema was developed using a document-oriented Not only Structured Query Language (NoSQL) approach. The proposed database is now with 379 exams, 838 nodules, and 8237 images, 4029 of them are CT scans and 4208 manually segmented nodules, and it is allocated in a MongoDB instance on a cloud infrastructure.

  19. Consistent interactive segmentation of pulmonary ground glass nodules identified in CT studies

    Science.gov (United States)

    Zhang, Li; Fang, Ming; Naidich, David P.; Novak, Carol L.

    2004-05-01

    Ground glass nodules (GGNs) have proved especially problematic in lung cancer diagnosis, as despite frequently being malignant they characteristically have extremely slow rates of growth. This problem is further magnified by the small size of many of these lesions now being routinely detected following the introduction of multislice CT scanners capable of acquiring contiguous high resolution 1 to 1.25 mm sections throughout the thorax in a single breathhold period. Although segmentation of solid nodules can be used clinically to determine volume doubling times quantitatively, reliable methods for segmentation of pure ground glass nodules have yet to be introduced. Our purpose is to evaluate a newly developed computer-based segmentation method for rapid and reproducible measurements of pure ground glass nodules. 23 pure or mixed ground glass nodules were identified in a total of 8 patients by a radiologist and subsequently segmented by our computer-based method using Markov random field and shape analysis. The computer-based segmentation was initialized by a click point. Methodological consistency was assessed using the overlap ratio between 3 segmentations initialized by 3 different click points for each nodule. The 95% confidence interval on the mean of the overlap ratios proved to be [0.984, 0.998]. The computer-based method failed on two nodules that were difficult to segment even manually either due to especially low contrast or markedly irregular margins. While achieving consistent manual segmentation of ground glass nodules has proven problematic most often due to indistinct boundaries and interobserver variability, our proposed method introduces a powerful new tool for obtaining reproducible quantitative measurements of these lesions. It is our intention to further document the value of this approach with a still larger set of ground glass nodules.

  20. Comparison of sensitivity and reading time for the use of computer-aided detection (CAD) of pulmonary nodules at MDCT as concurrent or second reader

    International Nuclear Information System (INIS)

    Beyer, F.; Zierott, L.; Juergens, K.U.; Heindel, W.; Fallenberg, E.M.; Stoeckel, J.; Wormanns, D.

    2007-01-01

    The purpose of this study was to compare sensitivity for detection of pulmonary nodules in MDCT scans and reading time of radiologists when using CAD as the second reader (SR) respectively concurrent reader (CR). Four radiologists analyzed 50 chest MDCT scans chosen from clinical routine two times and marked all detected pulmonary nodules: first with CAD as CR (display of CAD results immediately in the reading session) and later (median 14 weeks) with CAD as SR (display of CAD markers after completion of first reading without CAD). A Siemens LungCAD prototype was used. Sensitivities for detection of nodules and reading times were recorded. Sensitivity of reading with CAD as SR was significantly higher than reading without CAD (p < 0.001) and CAD as CR (p < 0.001). For nodule size of 1.75 mm or above no significant sensitivity difference between CAD as CR and reading without CAD was observed; e.g., for nodules above 4 mm sensitivity was 68% without CAD, 68% with CAD as CR (p 0.45) and 75% with CAD as SR (p < 0.001). Reading time was significantly shorter for CR (274 s) compared to reading without CAD (294 s; p = 0.04) and SR (337 s; p < 0.001). In our study CAD could either speed up reading of chest CT cases for pulmonary nodules without relevant loss of sensitivity when used as CR, or it increased sensitivity at the cost of longer reading times when used as SR. (orig.)

  1. Effect of the high-pitch mode in dual-source computed tomography on the accuracy of three-dimensional volumetry of solid pulmonary nodules: a phantom study.

    Science.gov (United States)

    Hwang, Sung Ho; Oh, Yu-Whan; Ham, Soo-Youn; Kang, Eun-Young; Lee, Ki Yeol

    2015-01-01

    To evaluate the influence of high-pitch mode (HPM) in dual-source computed tomography (DSCT) on the accuracy of three-dimensional (3D) volumetry for solid pulmonary nodules. A lung phantom implanted with 45 solid pulmonary nodules (n = 15 for each of 4-mm, 6-mm, and 8-mm in diameter) was scanned twice, first in conventional pitch mode (CPM) and then in HPM using DSCT. The relative percentage volume errors (RPEs) of 3D volumetry were compared between the HPM and CPM. In addition, the intermode volume variability (IVV) of 3D volumetry was calculated. In the measurement of the 6-mm and 8-mm nodules, there was no significant difference in RPE (p > 0.05, respectively) between the CPM and HPM (IVVs of 1.2 ± 0.9%, and 1.7 ± 1.5%, respectively). In the measurement of the 4-mm nodules, the mean RPE in the HPM (35.1 ± 7.4%) was significantly greater (p volumetry with HPM for solid pulmonary nodule is comparable to that with CPM. However, the use of HPM may adversely affect the accuracy of 3D volumetry for smaller (< 5 mm in diameter) nodule.

  2. Robust semi-automatic segmentation of pulmonary subsolid nodules in chest computed tomography scans

    International Nuclear Information System (INIS)

    Lassen, B C; Kuhnigk, J-M; Van Ginneken, B; Van Rikxoort, E M; Jacobs, C

    2015-01-01

    The malignancy of lung nodules is most often detected by analyzing changes of the nodule diameter in follow-up scans. A recent study showed that comparing the volume or the mass of a nodule over time is much more significant than comparing the diameter. Since the survival rate is higher when the disease is still in an early stage it is important to detect the growth rate as soon as possible. However manual segmentation of a volume is time-consuming. Whereas there are several well evaluated methods for the segmentation of solid nodules, less work is done on subsolid nodules which actually show a higher malignancy rate than solid nodules. In this work we present a fast, semi-automatic method for segmentation of subsolid nodules. As minimal user interaction the method expects a user-drawn stroke on the largest diameter of the nodule. First, a threshold-based region growing is performed based on intensity analysis of the nodule region and surrounding parenchyma. In the next step the chest wall is removed by a combination of a connected component analyses and convex hull calculation. Finally, attached vessels are detached by morphological operations. The method was evaluated on all nodules of the publicly available LIDC/IDRI database that were manually segmented and rated as non-solid or part-solid by four radiologists (Dataset 1) and three radiologists (Dataset 2). For these 59 nodules the Jaccard index for the agreement of the proposed method with the manual reference segmentations was 0.52/0.50 (Dataset 1/Dataset 2) compared to an inter-observer agreement of the manual segmentations of 0.54/0.58 (Dataset 1/Dataset 2). Furthermore, the inter-observer agreement using the proposed method (i.e. different input strokes) was analyzed and gave a Jaccard index of 0.74/0.74 (Dataset 1/Dataset 2). The presented method provides satisfactory segmentation results with minimal observer effort in minimal time and can reduce the inter-observer variability for segmentation of

  3. Robust semi-automatic segmentation of pulmonary subsolid nodules in chest computed tomography scans

    Science.gov (United States)

    Lassen, B. C.; Jacobs, C.; Kuhnigk, J.-M.; van Ginneken, B.; van Rikxoort, E. M.

    2015-02-01

    The malignancy of lung nodules is most often detected by analyzing changes of the nodule diameter in follow-up scans. A recent study showed that comparing the volume or the mass of a nodule over time is much more significant than comparing the diameter. Since the survival rate is higher when the disease is still in an early stage it is important to detect the growth rate as soon as possible. However manual segmentation of a volume is time-consuming. Whereas there are several well evaluated methods for the segmentation of solid nodules, less work is done on subsolid nodules which actually show a higher malignancy rate than solid nodules. In this work we present a fast, semi-automatic method for segmentation of subsolid nodules. As minimal user interaction the method expects a user-drawn stroke on the largest diameter of the nodule. First, a threshold-based region growing is performed based on intensity analysis of the nodule region and surrounding parenchyma. In the next step the chest wall is removed by a combination of a connected component analyses and convex hull calculation. Finally, attached vessels are detached by morphological operations. The method was evaluated on all nodules of the publicly available LIDC/IDRI database that were manually segmented and rated as non-solid or part-solid by four radiologists (Dataset 1) and three radiologists (Dataset 2). For these 59 nodules the Jaccard index for the agreement of the proposed method with the manual reference segmentations was 0.52/0.50 (Dataset 1/Dataset 2) compared to an inter-observer agreement of the manual segmentations of 0.54/0.58 (Dataset 1/Dataset 2). Furthermore, the inter-observer agreement using the proposed method (i.e. different input strokes) was analyzed and gave a Jaccard index of 0.74/0.74 (Dataset 1/Dataset 2). The presented method provides satisfactory segmentation results with minimal observer effort in minimal time and can reduce the inter-observer variability for segmentation of

  4. Additional value of FDG PET/CT to contrast-enhanced CT in the differentiation between benign and malignant intraductal papillary mucinous neoplasms of the pancreas with mural nodules

    International Nuclear Information System (INIS)

    Takanami, Kentaro; Hiraide, Tomomichi; Tsuda, Masashi; Nakamura, Yausuhiro; Kaneta, Tomohiro; Takase, Kei; Takahashi, Shoki; Fukuda, Hiroshi

    2011-01-01

    This study aimed at determining the additional value of F-18 fluorodeoxyglucose (FDG) positron emission tomography (PET)/CT to contrast-enhanced CT in the differentiation between benign and malignant intraductal papillary mucinous neoplasms (IPMNs) of the pancreas with mural nodules. This retrospective review of medical records was approved by our institutional review board. The preoperative PET/CT images of 16 non-diabetic patients with surgically proven IPMN, where mural nodules of 3 mm or larger were shown by preoperative contrast-enhanced CT, were retrospectively evaluated. The 16 patients were divided into two groups: 7 patients with benign IPMN [adenoma (n=1) and borderline tumor (n=6)] and 9 patients with malignant IPMN [carcinoma in situ (CIS) (n=8) and invasive carcinoma (n=1)]. Nuclear medicine physician blinded to the pathologic assessment of malignancy of IPMN set a spherical volume of interest (VOI) over the mural nodules on PET/CT images and recorded the peak standardized uptake value (SUV max ) in the VOI, referring the contrast-enhanced CT images. Statistical differences in the size of mural nodule, the diameter of main pancreatic duct (MPD), and SUV max of the tumors between benign IPMNs and malignant IPMNs were compared using the Mann-Whitney U test. Statistical significance was set at p max of the malignant IPMNs with mural nodules of 3 mm or larger was higher than that of benign IPMNs (2.7±0.6 vs. 1.9±0.3, p<0.01). Meanwhile, there was no significant difference in mural nodule diameter and MPD diameter between the two groups. FDG PET/CT showed an excellent diagnostic accuracy for the differentiation between malignant and benign IPMNs with mural nodules: the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy in malignant IPMN with mural nodule of FDG PET/CT were 77.8, 100, 100, 77.8, and 87.5 for the cutoff value of 2.3; and 100, 57.1, 75.0, 100, and 81.3 for the cutoff value of 2

  5. Correlation of emphysema score with perceived malignancy of pulmonary nodules: a multi-observer study using the LIDC-IDRI CT lung database

    Science.gov (United States)

    Wiemker, Rafael; Bülow, Thomas; Blaffert, Thomas; Dharaiya, Ekta

    2009-02-01

    Presence of emphysema is recognized to be one of the single most significant risk factors in risk models for the prediction of lung cancer. Therefore, an automatically computed emphysema score would be a prime candidate as an additional numerical feature for computer aided diagnosis (CADx) for indeterminate pulmonary nodules. We have applied several histogram-based emphysema scores to 460 thoracic CT scans from the IDRI CT lung image database, and analyzed the emphysema scores in conjunction with 3000 nodule malignancy ratings of 1232 pulmonary nodules made by expert observers. Despite the emphysema being a known risk factor, we have not found any impact on the readers' malignancy rating of nodules found in a patient with higher emphysema score. We have also not found any correlation between the number of expert-detected nodules in a patient and his emphysema score, or the relative craniocaudal location of the nodules and their malignancy rating. The inter-observer agreement of the expert ratings was excellent on nodule diameter (as derived from manual delineations), good for calcification, and only modest for malignancy and shape descriptions such as spiculation, lobulation, margin, etc.

  6. Correlation between the quantifiable parameters of blood flow pattern derived with dynamic CT in maliagnant solitary pulmonary nodules and tumor size

    Directory of Open Access Journals (Sweden)

    Chenshi ZHANG

    2008-02-01

    Full Text Available Background and Objective The solitary pulmonary nodules (SPNs is one of the most common findings on chest radiographs. It becomes possible to provide more accurately quantitative information about blood flow patterns of solitary pulmonary nodules (SPNs with multi-slice spiral computed tomography (MSCT. The aim of this study is to evaluate the correlation between the quantifiable parameters of blood flow pattern derived with dynamic CT in maliagnant solitary pulmonary nodules and tumor size. Methods 68 patients with maliagnant solitary pulmonary nodules (SPNs (diameter <=4 cmunderwent multi-location dynamic contrast material-enhanced (nonionic contrast material was administrated via the antecubital vein at a rate of 4mL/s by an autoinjector, 4*5mm or 4*2.5mm scanning mode with stable table were performed. serial CT. Precontrast and postcontrast attenuation on every scan was recorded. Perfusion (PSPN, peak height (PHSPNratio of peak height of the SPN to that of the aorta (SPN-to-A ratioand mean transit time(MTT were calculated. The correlation between the quantifiable parameters of blood flow pattern derived with dynamic CT in maliagnant solitary pulmonary nodules and tumor size were assessed by means of linear regression analysis. Results No significant correlations were found between the tumor size and each of the peak height (PHSPN ratio of peak height of the SPN to that of the aorta (SPN-to-A ratio perfusion(PSPNand mean transit time (r=0.18, P=0.14; r=0.20,P=0.09; r=0.01, P=0.95; r=0.01, P=0.93. Conclusion No significant correlation is found between the tumor size and each of the quantifiable parameters of blood flow pattern derived with dynamic CT in maliagnant solitary pulmonary nodules.

  7. SU-F-207-13: Comparison of Four Dimensional Computed Tomography (4D CT) Versus Breath Hold Images to Determine Pulmonary Nodule Elasticity

    Energy Technology Data Exchange (ETDEWEB)

    Negahdar, M; Loo, B; Maxim, P [Stanford University School of Medicine, Stanford, CA (United States)

    2015-06-15

    Purpose: Elasticity may distinguish malignant from benign pulmonary nodules. To compare determining of malignant pulmonary nodule (MPN) elasticity from four dimensional computed tomography (4D CT) images versus inhale/exhale breath-hold CT images. Methods: We analyzed phase 00 and 50 of 4D CT and deep inhale and natural exhale of breath-hold CT images of 30 MPN treated with stereotactic ablative radiotherapy (SABR). The radius of the smallest MPN was 0.3 cm while the biggest one was 2.1 cm. An intensity based deformable image registration (DIR) workflow was applied to the 4D CT and breath-hold images to determine the volumes of the MPNs and a 1 cm ring of surrounding lung tissue (ring) in each state. Next, an elasticity parameter was derived by calculating the ratio of the volume changes of MPN (exhale:inhale or phase50:phase00) to that of a 1 cm ring of lung tissue surrounding the MPN. The proposed formulation of elasticity enables us to compare volume changes of two different MPN in two different locations of lung. Results: The calculated volume ratio of MPNs from 4D CT (phase50:phase00) and breath-hold images (exhale:inhale) was 1.00±0.23 and 0.95±0.11, respectively. It shows the stiffness of MPN and comparably bigger volume changes of MPN in breath-hold images because of the deeper degree of inhalation. The calculated elasticity of MPNs from 4D CT and breath-hold images was 1.12±0.22 and 1.23±0.26, respectively. For five patients who have had two MPN in their lung, calculated elasticity of tumor A and tumor B follows same trend in both 4D CT and breath-hold images. Conclusion: We showed that 4D CT and breath-hold images are comparable in the ability to calculate the elasticity of MPN. This study has been supported by Department of Defense LCRP 2011 #W81XWH-12-1-0286.

  8. Automatic detection of spiculation of pulmonary nodules in computed tomography images

    DEFF Research Database (Denmark)

    Ciompi, F; Jacobs, C; Scholten, E.T.

    2015-01-01

    to classify spiculated nodules via supervised learning. We tested our approach on a set of nodules from the Danish Lung Cancer Screening Trial (DLCST) dataset. Our results show that the proposed method outperforms other 3-D descriptors of morphology in the automatic assessment of spiculation. © (2015......-up procedure. For this reason, lung cancer screening scenario would benefit from the presence of a fully automatic system for the assessment of spiculation. The presented framework relies on the fact that spiculated nodules mainly differ from non-spiculated ones in their morphology. In order to discriminate....... A library of spectra is created by clustering data via unsupervised learning. The centroids of the clusters are used to label back each spectrum in the sampling pattern. A compact descriptor encoding the nodule morphology is obtained as the histogram of labels along all the spherical surfaces and used...

  9. Computed tomography findings in patients with pulmonary hyalinizing granulomas: a case report

    International Nuclear Information System (INIS)

    Marchiori, Edson; Valiante, Paulo Marcos; Correia, Ana Helena Pereira; Carneiro, Leonardo Hoehl; Caldas, Carolina Rodrigues; Souza Junior, Arthur Soares

    2003-01-01

    Hyalinizing granulomas are benign fibrotic lesions that generally present multiple nodules seen on radiological examinations, which are frequently cavitary and/or calcified lesions. We report a case of a 28 year-old-woman with hyalinizing granulomas probably secondary to a previous tuberculosis infection. Hyalinizing granulomas should be included in the differential diagnosis of patients with multiple pulmonary nodules. (author)

  10. Implication of the first decision on visual information-sampling in the spatial frequency domain in pulmonary nodule recognition

    Science.gov (United States)

    Pietrzyk, Mariusz W.; Manning, David; Donovan, Tim; Dix, Alan

    2010-02-01

    Aim: To investigate the impact on visual sampling strategy and pulmonary nodule recognition of image-based properties of background locations in dwelled regions where the first overt decision was made. . Background: Recent studies in mammography show that the first overt decision (TP or FP) has an influence on further image reading including the correctness of the following decisions. Furthermore, the correlation between the spatial frequency properties of the local background following decision sites and the first decision correctness has been reported. Methods: Subjects with different radiological experience were eye tracked during detection of pulmonary nodules from PA chest radiographs. Number of outcomes and the overall quality of performance are analysed in terms of the cases where correct or incorrect decisions were made. JAFROC methodology is applied. The spatial frequency properties of selected local backgrounds related to a certain decisions were studied. ANOVA was used to compare the logarithmic values of energy carried by non redundant stationary wavelet packet coefficients. Results: A strong correlation has been found between the number of TP as a first decision and the JAFROC score (r = 0.74). The number of FP as a first decision was found negatively correlated with JAFROC (r = -0.75). Moreover, the differential spatial frequency profiles outcomes depend on the first choice correctness.

  11. Solitary pulmonary nodules: accuracy and cost-effectiveness of sodium iodide FDG-PET using Australian data

    International Nuclear Information System (INIS)

    Keith, C.J.; Miles, K.A.; Griffiths, M.R.; Wong, D.; Pitman, A.G.; Hicks, R.J.

    2002-01-01

    This study uses Australian data to confirm the accuracy of dedicated sodium iodide (NaI) fluorine-18 fluorodeoxyglucose positron emission tomography (FDG-PET) in evaluating indeterminate solitary pulmonary nodules (SPNs) and to determine the conditions under which PET could play a cost-effective role in this evaluation. Ninety-two patients from two Australian hospitals in different states underwent FDG-PET for evaluation of an SPN. Observed values for prior probability of malignancy and diagnostic accuracy of PET were applied to previously published decision tree models using published Australian health care costs. The accuracy of FDG-PET was 93% with a sensitivity of 92% and a specificity of 95%. The prior probability of malignancy (0.54), PET sensitivity and PET specificity indicated cost savings per patient of up to EUR 455 (A$ 774) based on a PET cost of EUR 706 (A$ 1,200). PET would remain cost-effective for levels of prior probability up to 0.8-0.9 and a PET cost of EUR 736-1,161 (A$ 1,252-A$ 1,974). It is concluded that NaI PET is accurate, cost saving and cost-effective for the characterisation of indeterminate pulmonary nodules in Australia. Comparison with previous reports from the United States confirms that FDG-PET can remain cost-effective despite population differences in medical costs, disease prevalence and PET diagnostic performance. (orig.)

  12. Evaluation of chest tomosynthesis for the detection of pulmonary nodules: effect of clinical experience and comparison with chest radiography

    Science.gov (United States)

    Zachrisson, Sara; Vikgren, Jenny; Svalkvist, Angelica; Johnsson, Åse A.; Boijsen, Marianne; Flinck, Agneta; Månsson, Lars Gunnar; Kheddache, Susanne; Båth, Magnus

    2009-02-01

    Chest tomosynthesis refers to the technique of collecting low-dose projections of the chest at different angles and using these projections to reconstruct section images of the chest. In this study, a comparison of chest tomosynthesis and chest radiography in the detection of pulmonary nodules was performed and the effect of clinical experience of chest tomosynthesis was evaluated. Three senior thoracic radiologists, with more than ten years of experience of chest radiology and 6 months of clinical experience of chest tomosynthesis, acted as observers in a jackknife free-response receiver operating characteristics (JAFROC-1) study, performed on 42 patients with and 47 patients without pulmonary nodules examined with both chest tomosynthesis and chest radiography. MDCT was used as reference and the total number of nodules found using MDCT was 131. To investigate the effect of additional clinical experience of chest tomosynthesis, a second reading session of the tomosynthesis images was performed one year after the initial one. The JAFROC-1 figure of merit (FOM) was used as the principal measure of detectability. In comparison with chest radiography, chest tomosynthesis performed significantly better with regard to detectability. The observer-averaged JAFROC-1 FOM was 0.61 for tomosynthesis and 0.40 for radiography, giving a statistically significant difference between the techniques of 0.21 (p<0.0001). The observer-averaged JAFROC-1 FOM of the second reading of the tomosynthesis cases was not significantly higher than that of the first reading, indicating no improvement in detectability due to additional clinical experience of tomosynthesis.

  13. The incidental pulmonary nodule in a child. Part 1: recommendations from the SPR Thoracic Imaging Committee regarding characterization, significance and follow-up

    Energy Technology Data Exchange (ETDEWEB)

    Westra, Sjirk J. [Massachusetts General Hospital, Division of Pediatric Radiology, Boston, MA (United States); Brody, Alan S. [Cincinnati Children' s Hospital Medical Center, Department of Radiology (CH-1), Cincinnati, OH (United States); Mahani, Maryam Ghadimi [University of Michigan Health System, Section of Pediatric Radiology, C. S. Mott Children' s Hospital Department of Radiology, Ann Arbor, MI (United States); Guillerman, R.P. [Texas Children' s Hospital, Department of Radiology, Houston, TX (United States); Hegde, Shilpa V. [Arkansas Children' s Hospital, Department of Radiology, Little Rock, AR (United States); Iyer, Ramesh S. [Seattle Children' s Hospital, Department of Radiology, Seattle, WA (United States); Lee, Edward Y. [Boston Children' s Hospital, Department of Pediatric Radiology, Boston, MA (United States); Newman, Beverley [Lucile Packard Children' s Hospital at Stanford University, Department of Radiology, Stanford, CA (United States); Podberesky, Daniel J. [Nemours Children' s Hospital, Department of Radiology, Orlando, FL (United States); Thacker, Paul G. [Medical University of South Carolina, Department of Radiology, Charleston, SC (United States)

    2015-05-01

    No guidelines are in place for the follow-up and management of pulmonary nodules that are incidentally detected on CT in the pediatric population. The Fleischner guidelines, which were developed for the older adult population, do not apply to children. This review summarizes the evidence collected by the Society for Pediatric Radiology (SPR) Thoracic Imaging Committee in its attempt to develop pediatric-specific guidelines. Small pulmonary opacities can be characterized as linear or as ground-glass or solid nodules. Linear opacities and ground-glass nodules are extremely unlikely to represent an early primary or metastatic malignancy in a child. In our review, we found a virtual absence of reported cases of a primary pulmonary malignancy presenting as an incidentally detected small lung nodule on CT in a healthy immune-competent child. Because of the lack of definitive information on the clinical significance of small lung nodules that are incidentally detected on CT in children, the management of those that do not have the typical characteristics of an intrapulmonary lymph node should be dictated by the clinical history as to possible exposure to infectious agents, the presence of an occult immunodeficiency, the much higher likelihood that the nodule represents a metastasis than a primary lung tumor, and ultimately the individual preference of the child's caregiver. Nodules appearing in children with a history of immune deficiency, malignancy or congenital pulmonary airway malformation should not be considered incidental, and their workup should be dictated by the natural history of these underlying conditions. (orig.)

  14. Solitary pulmonary nodules: meta-analytic comparison of cross-sectional imaging modalities for diagnosis of malignancy.

    Science.gov (United States)

    Cronin, Paul; Dwamena, Ben A; Kelly, Aine Marie; Carlos, Ruth C

    2008-03-01

    To perform a meta-analysis to estimate the diagnostic accuracy of dynamic contrast material-enhanced computed tomography (CT) and magnetic resonance (MR) imaging, fluorine 18 fluorodeoxyglucose (FDG) positron emission tomography (PET), and technetium 99m ((99m)Tc) depreotide single photon emission computed tomography (SPECT) for evaluation of solitary pulmonary nodules (SPNs). Data sources were studies published in PubMed between January 1990 and December 2005. The selected investigations were comparative and noncomparative diagnostic cohort studies to examine the operating characteristics of the four imaging modalities for evaluation of SPNs, involving at least 10 enrolled participants with histologic confirmation and having sufficient data to calculate contingency tables. A random coefficient binary regression model with disease probability conditioned on test results was used to summarize test performance and construct summary receiver operating characteristic (ROC) curves. Sensitivities, specificities, predictive values, diagnostic odds ratios, and areas under the ROC curve were calculated. Forty-four studies--10 dynamic CT, six dynamic MR, 22 FDG PET, and seven (99m)Tc-depreotide SPECT--met the inclusion criteria. (One study was included in both the FDG PET and SPECT groups.) Sensitivities, specificities, positive predictive values, negative predictive values, diagnostic odds ratios, and areas under the ROC curve were, respectively, 0.93 (95% confidence interval [CI]: 0.88, 0.97), 0.76 (95% CI: 0.68, 0.97), 0.80 (95% CI: 0.74, 0.86), 0.95 (95% CI: 0.93, 0.98), 39.91 (95% CI: 1.21, 81.04), and 0.93 (95% CI: 0.81, 0.97) for dynamic CT; 0.94 (95% CI: 0.91, 0.97), 0.79 (95% CI: 0.73, 0.86), 0.86 (95% CI: 0.83, 0.89), 0.93 (95% CI: 0.90, 0.96), 60.59 (95% CI: 5.56, 115.62), and 0.94 (95% CI: 0.83, 0.98) for dynamic MR; 0.95 (95% CI: 0.93, 0.98), 0.82 (95% CI: 0.77, 0.88), 0.91 (95% CI: 0.88, 0.93), 0.90 (95% CI: 0.85, 0.94), 97.31 (95% CI: 6.26, 188.37), and 0

  15. Emphysema and soluble CD14 are associated with pulmonary nodules in HIV-infected patients: implications for lung cancer screening.

    Science.gov (United States)

    Triplette, Matthew; Sigel, Keith M; Morris, Alison; Shahrir, Shahida; Wisnivesky, Juan P; Kong, Chung Y; Diaz, Phillip T; Petraglia, Alycia; Crothers, Kristina

    2017-07-31

    Lung cancer screening may benefit HIV-infected (HIV) smokers because of an elevated risk of lung cancer, but may have unique harms because of HIV-specific risk factors for false-positive screens. This study seeks to understand whether inflammatory biomarkers and markers of chronic lung disease are associated with noncalcified nodules at least 4 mm (NCN) in HIV compared with uninfected patients. This is a cohort study of Examinations of HIV-Associated Lung Emphysema (EXHALE), including 158 HIV and 133 HIV-uninfected participants. Participants underwent a laboratory assessment [including measurement of D-dimer, interleukin 6, and soluble CD14 (sCD14)], chest computed tomography (CT), and pulmonary function testing. We created multivariable logistic regression models to determine predictors of NCN in the participants stratified by HIV status, with attention to semiqualitative scoring of radiographic emphysema, markers of pulmonary function, and inflammatory biomarkers. Of the 291 participants, 69 had NCN on chest CT. As previously reported, there was no difference in prevalence of these nodules by HIV status. Emphysema and elevated sCD14 demonstrated an association with NCN in HIV participants independent of smoking status, CD4 cell count, HIV viral load, and pulmonary function. Emphysema and sCD14, a marker of immune activation, was associated with a higher prevalence of NCN on chest CT in HIV participants. Patients with chronic immune activation and emphysema may be at higher risk for both false-positive findings and incident lung cancer, thus screening in this group requires further study to understand the balance of benefits and harms.

  16. Improved detection of pulmonary nodules on energy-subtracted chest radiographs with a commercial computer-aided diagnosis software: comparison with human observers

    International Nuclear Information System (INIS)

    Szucs-Farkas, Zsolt; Patak, Michael A.; Yuksel-Hatz, Seyran; Ruder, Thomas; Vock, Peter

    2010-01-01

    To retrospectively analyze the performance of a commercial computer-aided diagnosis (CAD) software in the detection of pulmonary nodules in original and energy-subtracted (ES) chest radiographs. Original and ES chest radiographs of 58 patients with 105 pulmonary nodules measuring 5-30 mm and images of 25 control subjects with no nodules were randomized. Five blinded readers evaluated firstly the original postero-anterior images alone and then together with the subtracted radiographs. In a second phase, original and ES images were analyzed by a commercial CAD program. CT was used as reference standard. CAD results were compared to the readers' findings. True-positive (TP) and false-positive (FP) findings with CAD on subtracted and non-subtracted images were compared. Depending on the reader's experience, CAD detected between 11 and 21 nodules missed by readers. Human observers found three to 16 lesions missed by the CAD software. CAD used with ES images produced significantly fewer FPs than with non-subtracted images: 1.75 and 2.14 FPs per image, respectively (p=0.029). The difference for the TP nodules was not significant (40 nodules on ES images and 34 lesions in non-subtracted radiographs, p = 0.142). CAD can improve lesion detection both on energy subtracted and non-subtracted chest images, especially for less experienced readers. The CAD program marked less FPs on energy-subtracted images than on original chest radiographs. (orig.)

  17. Incidental detection of prostate-specific antigen-negative metastatic prostate cancer initially presented with solitary pulmonary nodule on fluorodeoxyglucose positron emission tomography/computed tomography

    International Nuclear Information System (INIS)

    Erdogan, Ezgi Basak; Buyukpinarbasili, Nur; Ziyade, Sedat; Akman, Tolga; Turk, Haci Mehmet; Aydin, Mehmet

    2005-01-01

    A 71-year-old male patient with solitary pulmonary nodule underwent fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) showing slightly increased FDG uptake in this nodule. In addition, PET/CT detected hypermetabolic sclerotic bone lesions in the right second rib and 7 th thoracic vertebrae, which were interpreted as possible metastases, and mildly increased FDG uptake in the prostate gland highly suspicious of malignancy. The patient's prostate-specific antigen (PSA) level was within normal range (3.8 ng/dL). The histopathological examination of the lung nodule and right second rib lesion proved metastases from prostate cancer, then the prostate biopsy-confirmed prostate adenocarcinoma. The unique feature of this case is to emphasize the importance of performing PET/CT for solitary pulmonary nodule in detecting PSA-negative metastatic prostate cancer. This case indicated that it should be kept in mind that, even if the PSA is negative, a lung metastasis of prostate cancer may be an underlying cause in patients evaluated for solitary pulmonary nodule by FDG PET/CT

  18. Pulmonary Nodule Volumetry at Different Low Computed Tomography Radiation Dose Levels With Hybrid and Model-Based Iterative Reconstruction: A Within Patient Analysis.

    Science.gov (United States)

    den Harder, Annemarie M; Willemink, Martin J; van Hamersvelt, Robbert W; Vonken, Evertjan P A; Schilham, Arnold M R; Lammers, Jan-Willem J; Luijk, Bart; Budde, Ricardo P J; Leiner, Tim; de Jong, Pim A

    2016-01-01

    The aim of the study was to determine the effects of dose reduction and iterative reconstruction (IR) on pulmonary nodule volumetry. In this prospective study, 25 patients scheduled for follow-up of pulmonary nodules were included. Computed tomography acquisitions were acquired at 4 dose levels with a median of 2.1, 1.2, 0.8, and 0.6 mSv. Data were reconstructed with filtered back projection (FBP), hybrid IR, and model-based IR. Volumetry was performed using semiautomatic software. At the highest dose level, more than 91% (34/37) of the nodules could be segmented, and at the lowest dose level, this was more than 83%. Thirty-three nodules were included for further analysis. Filtered back projection and hybrid IR did not lead to significant differences, whereas model-based IR resulted in lower volume measurements with a maximum difference of -11% compared with FBP at routine dose. Pulmonary nodule volumetry can be accurately performed at a submillisievert dose with both FBP and hybrid IR.

  19. Solitary extramedullary plasmacytomas of thyroid in Hashimoto's thyroiditis: Mimicking benign cystic nodule on ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Yohan; Kim, Soo Jin; Hur, Joon Ho; Park, Sung Hee; Lee, Sun Jin; Lee, Tae Jin [Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul (Korea, Republic of)

    2013-11-15

    Solitary extramedullary plasmacytoma (SEP) of the thyroid is uncommon and mostly occur in patients with a Hashimoto's thyroiditis (82%). We present a case on SEP of thyroid in Hashimoto's thyroiditis, which mimics growing benign cystic masses on serial ultrasonography.

  20. Association of Decision-making with Patients' Perceptions of Care and Knowledge during Longitudinal Pulmonary Nodule Surveillance.

    Science.gov (United States)

    Sullivan, Donald R; Golden, Sara E; Ganzini, Linda; Wiener, Renda Soylemez; Eden, Karen B; Slatore, Christopher G

    2017-11-01

    Patient participation in medical decision-making is widely advocated, but outcomes are inconsistent. We examined the associations between medical decision-making roles, and patients' perceptions of their care and knowledge while undergoing pulmonary nodule surveillance. The study setting was an academically affiliated Veterans Affairs hospital network in which 121 participants had 319 decision-making encounters. The Control Preferences Scale was used to assess patients' decision-making roles. Associations between decision-making, including role concordance (i.e., agreement between patients' preferred and actual roles), shared decision-making (SDM), and perceptions of care and knowledge, were assessed using logistic regression and generalized estimating equations. Participants had a preferred role in 98% of encounters, and most desired an active role (shared or patient controlled). For some encounters (36%), patients did not report their actual decision-making role, because they did not know what their role was. Role concordance and SDM occurred in 56% and 26% of encounters, respectively. Role concordance was associated with greater satisfaction with medical care (adjusted odds ratio [Adj-OR], 5.39; 95% confidence interval [CI], 1.68-17.26), higher quality of patient-reported care (Adj-OR, 2.86; 95% CI, 1.31-6.27), and more disagreement that care could be better (Adj-OR, 2.16; 95% CI, 1.12-4.16). Role concordance was not associated with improved pulmonary nodule knowledge with respect to lung cancer risk (Adj-OR, 1.12; 95% CI, 0.63-2.00) or nodule information received (Adj-OR, 1.13; 95% CI, 0.31-4.13). SDM was not associated with perceptions of care or knowledge. Among patients undergoing longitudinal nodule surveillance, a majority had a preference for having active roles in decision-making. Interestingly, during some encounters, patients did not know what their role was or that a decision was being made. Role concordance was associated with greater patient

  1. Automated pulmonary nodule volumetry with an optimized algorithm - accuracy at different slice thicknesses compared to unidimensional and bidimentional measurements

    International Nuclear Information System (INIS)

    Vogel, M.N.; Schmuecker, S.; Maksimovich, O.; Claussen, C.D.; Horger, M.; Vonthein, R.; Bethge, W.; Dicken, V.

    2008-01-01

    Purpose: This in-vivo study quantifies the accuracy of automated pulmonary nodule volumetry in reconstructions with different slice thicknesses (ST) of clinical routine CT scans. The accuracy of volumetry is compared to that of unidimensional and bidimensional measurements. Materials and Methods: 28 patients underwent contrast enhanced 64-row CT scans of the chest and abdomen obtained in the clinical routine. All scans were reconstructed with 1, 3, and 5 mm ST. Volume, maximum axial diameter, and areas following the guidelines of Response Evaluation Criteria in Solid Tumors (RECIST) and the World Health Organization (WHO) were measured in all 101 lesions located in the overlap region of both scans using the new software tool OncoTreat (MeVis, Deutschland). The accuracy of quantifications in both scans was evaluated using the Bland and Altmann method. The reproducibility of measurements in dependence on the ST was compared using the likelihood ratio Chi-squared test. Results: A total of 101 nodules were identified in all patients. Segmentation was considered successful in 88.1% of the cases without local manual correction which was deliberately not employed in this study. For 80 nodules all 6 measurements were successful. These were statistically evaluated. The volumes were in the range 0.1 to 15.6 ml. Of all 80 lesions, 34 (42%) had direct contact to the pleura parietalis oder diaphragmalis and were termed parapleural, 32 (40%) were paravascular, 7 (9%) both parapleural and paravascular, the remaining 21 (27%) were free standing in the lung. The trueness differed significantly (Chi-square 7.22, p value 0.027) and was best with an ST of 3 mm and worst at 5 mm. Differences in precision were not significant (Chi-square 5.20, p value 0.074). The limits of agreement for an ST of 3 mm were ± 17.5% of the mean volume for volumetry, for maximum diameters ± 1.3 mm, and ± 31.8% for the calculated areas. Conclusion: Automated volumetry of pulmonary nodules using Onco

  2. The clinical significance of perioperative serum IL-10 level changes in patients with benign and malignant pulmonary diseases

    International Nuclear Information System (INIS)

    Qi Falian; Xu Jun; Du Xiumin; Lu Zhaotong; Fu Qiang

    2003-01-01

    Objective: To study the clinical significance of perioperative changes of serum IL-10 level in patients with benign and malignant pulmonary diseases. Methods: Serum IL-10 levels in patients with benign (n=17) and malignant (n=25) pulmonary diseases were measured before and 1, 3, 7, 14 days after operation with RIA. Values in 82 controls were also taken. Results: The preoperative levels of serum IL-10 in patients with lung cancer were significantly higher than those in other groups (p 0.05); The levels of serum IL-10 in 36.4% of all the patients with lung cancer on day 14 were higher than the upper limit of the normal value. In patients with benign lung diseases, perioperative changes were slight and non-significant. Conclusion: Serum IL-10 level is a reliable parameter for distinguishing benign lung disease from malignant ones. Defining preoperative and postoperative changes of serum IL-10 levels might be of prognostic value in patients with lung cancer

  3. The impact of reconstruction techniques on observer performance for the detection and characterization of small pulmonary nodules in chest CT of children under 13 years

    NARCIS (Netherlands)

    Verhagen, Martijn V.; Smets, Anne M. J. B.; van Schuppen, Joost; Deurloo, Eline E.; Schaefer-Prokop, Cornelia

    2018-01-01

    To compare three different reconstruction techniques of CT data for the detection of pulmonary nodules in children under 13 years. Secondly to assess the prevalence of perifissural nodular opacities. The study consisted of chest CTs of 31 children (median age 6.9 years, range 2.1-12.7), of whom 17

  4. Towards automatic pulmonary nodule management in lung cancer screening with deep learning

    NARCIS (Netherlands)

    Ciompi, F.; Chung, K; Riel, S.J. van; Setio, A.A.A.; Gerke, P.K.; Jacobs, C.; Scholten, E.T.; Schaefer-Prokop, C.M.; Wille, M.M.W.; Marchiano, A.; Pastorino, U.; Prokop, M.; Ginneken, B. van

    2017-01-01

    The introduction of lung cancer screening programs will produce an unprecedented amount of chest CT scans in the near future, which radiologists will have to read in order to decide on a patient follow-up strategy. According to the current guidelines, the workup of screen-detected nodules strongly

  5. Detection of pulmonary nodules. Improvement by new screen-film systems?

    International Nuclear Information System (INIS)

    Lehmann, K.J.; Himmighoefer, U.

    1994-01-01

    In addition to digital radiography and AMBER, the development of asymmetric screen-film systems is another attempt to optimize chest radiography. Due to reduced contrast in the parenchyma, the former asymmetric screen-film systems did not show sufficient image quality. Three new asymmetric systems with completely different composition are available now. In-Sight VHC (Kodak), High Light GUV (3M) and Opthos D (Agfa) were compared to standard chest films using densitometric curves, a chest phantom for high and low contrast detectability, a nodule detection phantom and patient studies. The sensitivity of nodule detection in the mediastinum has been 41-48% for L-films and 58-65% for the asymmetric screen-film systems. No differences could be demonstrated for nodule detection in the lung field. Contrast in the parenchyma is equivalent to L-films. There is no loss of diagnostic information in the lung field. Differences between the asymmetric systems concern speed, dynamic range and granularity. If AMBER and digital radiography are not available, new asymmetric screen-film systems can improve nodule detection without further investment costs. (orig.) [de

  6. Interscan variation of semi-automated volumetry of subsolid pulmonary nodules

    NARCIS (Netherlands)

    Scholten, Ernst Th; de Jong, Pim A.; Jacobs, Colin; van Ginneken, Bram; van Riel, Sarah; Willemink, Martin J.; Vliegenthart, Rozemarijn; Oudkerk, Matthijs; de Koning, Harry J.; Horeweg, Nanda; Prokop, Mathias; Mali, Willem P. Th. M.; Gietema, Hester A.

    We aimed to test the interscan variation of semi-automatic volumetry of subsolid nodules (SSNs), as growth evaluation is important for SSN management. From a lung cancer screening trial all SSNs that were stable over at least 3 months were included (N = 44). SSNs were quantified on the baseline CT

  7. Clinical implications of nonspecific pulmonary nodules identified during the initial evaluation of patients with head and neck squamous cell carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Minsu [Eulji University School of Medicine, Department of Otorhinolaryngology, Eulji Medical Center, Seoul (Korea, Republic of); Lee, Sang Hoon; Lee, Yoon Se; Roh, Jong-Lyel; Choi, Seung-Ho; Nam, Soon Yuhl; Kim, Sang Yoon [Asan Medical Center, University of Ulsan College of Medicine, Department of Otolaryngology, Songpa-gu, Seoul (Korea, Republic of); Lee, Choong Wook [Asan Medical Center, University of Ulsan College of Medicine, Department of Radiology, Seoul (Korea, Republic of)

    2017-09-15

    We aimed to identify the clinical implications of nonspecific pulmonary nodules (NPNs) detected in the initial staging workup for patients with head and neck squamous cell carcinoma (HNSCC). Medical records of patients who had been diagnosed and treated in our hospital were retrospectively analysed. After definite treatment, changes of NPNs detected on initial evaluation were monitored via serial chest computed tomography. The associations between NPNs and the clinicopathological characteristics of primary HNSCC were evaluated. Survival analyses were performed according to the presence of NPNs. The study consisted of 158 (49.4%) patients without NPNs and 162 (50.6%) patients with NPNs. The cumulative incidence of probabilities of pulmonary malignancy (PM) development at 2 years after treatment were 9.0% and 6.2% in NPN-negative and NPN-positive patients, respectively. Overall and PM-free survival rates were not significantly different according to NPN status. Cervical lymph node (LN) involvement and a platelet-lymphocyte ratio (PLR) ≥126 increased the risk of PMs (both P <0.05). NPNs detected in the initial evaluation of patients with HNSCC did not predict the risk of pulmonary malignancies. Cervical LN involvement and PLR ≥126 may be independent prognostic factors affecting PM-free survival regardless of NPN status. (orig.)

  8. Risk-related 18F-FDG PET/CT and new diagnostic strategies in patients with solitary pulmonary nodule: the ITALIAN multicenter trial.

    Science.gov (United States)

    Spadafora, Marco; Pace, Leonardo; Evangelista, Laura; Mansi, Luigi; Del Prete, Francesco; Saladini, Giorgio; Miletto, Paolo; Fanti, Stefano; Del Vecchio, Silvana; Guerra, Luca; Pepe, Giovanna; Peluso, Giuseppina; Nicolai, Emanuele; Storto, Giovanni; Ferdeghini, Marco; Giordano, Alessandro; Farsad, Mohsen; Schillaci, Orazio; Gridelli, Cesare; Cuocolo, Alberto

    2018-05-05

    Diagnosis of solitary pulmonary nodule (SPN) is an important public health issue and 18 F-FDG PET/CT has proven to be more effective than CT alone. Pre-test risk stratification and clinical presentation of SPN could affect the diagnostic strategy. A relevant issue is whether thoracic segmental (s)-PET/CT could be implemented in patients with SPN. This retrospective multicenter study compared the results of FDG whole-body (wb)-PET/CT to those of s-PET/CT. 18 F-FDG PET/CT of 502 patients, stratified for pre-test cancer risk, were retrospectively analyzed. The thoracic part of wb-PET/CT, considered s-PET/CT, was compared to wb-PET/CT. Clinical and PET/CT variables were investigated for SPN characterization as well as for identification of patients in whom s-PET/CT could be performed. Histopathology or follow-up data were used as a reference. In the study population, 36% had malignant, 35% benign, and 29% indeterminate SPN. 18 F-FDG uptake indicative of thoracic and extra-thoracic lesions was detectable in 13% and 3% of the patients. All patients with extra-thoracic metastases (n = 13) had thoracic lymph node involvement and highest 18 F-FDG uptake at level of SPN (negative predictive value 100%). Compared to wb-PET/CT, s-PET/CT could save about 2/3 of 18 F-FDG dose, radiation exposure or scan-time, without affecting the clinical impact of PET/CT. Pre-test probability of malignancy can guide the diagnostic strategy of 18 FDG-PET/CT in patients with SPN. In subjects with low-intermediate pretest probability s-PET/CT imaging might be planned in advance, while in those at high risk and with thoracic lymph node involvement a wb-PET/CT is necessary.

  9. The use of computerised tomography guided percutaneous fine needle aspiration in the evaluation of solitary pulmonary nodules.

    LENUS (Irish Health Repository)

    Khan, K A

    2012-02-01

    The evaluation of a solitary pulmonary nodule (SPN) has changed over the years with increased access to percutaneous computerised tomography (CT) guided fine needle aspiration (FNA), where bronchoscopy is unhelpful. The aim of our study was to evaluate the sample adequacy, diagnostic and complication rate of CT-FNA of a SPN at our academic teaching hospital over an 18 month period. CT-FNA was performed by a radiologist, with a cytopathologist in attendance to confirm the adequacy of the sample obtained. The size of the nodule, sample material and adequacy, diagnosis and complications were recorded. A total of 101 patients were included, 54 male and the mean age was 68 +\\/- 11 years. The mean size of the SPN was 2.3 cm (range 1-11 cm). 56 (56%) patients had a right SPN, 45 (45%) had a left SPN. CT-FNA was diagnostic in 80 (80%) patients and non-diagnostic in 21 (20%) patients. The sample was insufficient for immunocytochemistry, although the morphological appearance was diagnostic in 20 (25%) of the 80 patients. Pneumothorax occurred in 26\\/101 (26%) patients post CT-FNA, of these 7 (27%) required chest drain insertion, while 19 (73%) were managed conservatively. CT FNA is a useful tool for the diagnosis of a SPN, with our diagnostic accuracy comparable to that reported in the literature. However, CT-FNA may not provide adequate sample volume to perform ancillary testing and has a moderate complication rate.

  10. The additional value of the lateral chest radiograph for the detection of small pulmonary nodules-a ROC analysis.

    Science.gov (United States)

    Kluthke, Robin Alexander; Kickuth, Ralph; Bansmann, Paul Martin; Tüshaus, Carolin; Adams, Stephan; Liermann, Dieter; Kirchner, Johannes

    2016-11-01

    For the past 30 years, many authors have described different advantages of the use of the additional lateral chest radiograph. However, some radiologic departments gave up performing the lateral view recently. A potential reason for this might be a lack of evidence for any diagnostic benefit of the additional lateral view of the thorax in recent studies. The objective of this study was to evaluate the diagnostic benefit of the additional lateral view for the detection of small pulmonary nodules compared with CT examinations as a gold standard. The patient population consisted of 45 patients with SPN and 45 patients without SPN. Four radiologists with varying experience in the assessment of thoracic imaging first examined the sole posteroanterior (PA) projection. After a few days, they were instructed to examine the PA and the additional lateral view. A receiver-operating characteristic analysis was accomplished to compare the documented results. The mean Az value of the sole PA view was 0.75 and 0.77 by the combination of PA and additional lateral view. So, there was no significant difference between the detectable Az values (Δ = 0.02; p = 0.384). With a cut-off value of >3, the additional view even reduced the sensitivity by averaging to 5.6%. The decrease of sensitivity by using the additional view was most detectable within the group of more experienced radiologists. The additional lateral view of the chest provides no diagnostic benefit in the detection of small pulmonary nodules in comparison with the sole PA projection. Nevertheless, the results of the present study must not be understood as a general evaluation of the benefits of the lateral radiograph per se, because we did not examine other relevant issues (i.e. cardiac failure, lung parenchyma diseases or abnormalities in hilar anatomy). Advances in knowledge: Our study demonstrates a lack of evidence for any diagnostic benefit of the additional lateral view of the thorax in detecting SPN.

  11. Multi-Institutional Evaluation of Digital Tomosynthesis, Dual-Energy Radiography, and Conventional Chest Radiography for the Detection and Management of Pulmonary Nodules.

    Science.gov (United States)

    Dobbins, James T; McAdams, H Page; Sabol, John M; Chakraborty, Dev P; Kazerooni, Ella A; Reddy, Gautham P; Vikgren, Jenny; Båth, Magnus

    2017-01-01

    Purpose To conduct a multi-institutional, multireader study to compare the performance of digital tomosynthesis, dual-energy (DE) imaging, and conventional chest radiography for pulmonary nodule detection and management. Materials and Methods In this binational, institutional review board-approved, HIPAA-compliant prospective study, 158 subjects (43 subjects with normal findings) were enrolled at four institutions. Informed consent was obtained prior to enrollment. Subjects underwent chest computed tomography (CT) and imaging with conventional chest radiography (posteroanterior and lateral), DE imaging, and tomosynthesis with a flat-panel imaging device. Three experienced thoracic radiologists identified true locations of nodules (n = 516, 3-20-mm diameters) with CT and recommended case management by using Fleischner Society guidelines. Five other radiologists marked nodules and indicated case management by using images from conventional chest radiography, conventional chest radiography plus DE imaging, tomosynthesis, and tomosynthesis plus DE imaging. Sensitivity, specificity, and overall accuracy were measured by using the free-response receiver operating characteristic method and the receiver operating characteristic method for nodule detection and case management, respectively. Results were further analyzed according to nodule diameter categories (3-4 mm, >4 mm to 6 mm, >6 mm to 8 mm, and >8 mm to 20 mm). Results Maximum lesion localization fraction was higher for tomosynthesis than for conventional chest radiography in all nodule size categories (3.55-fold for all nodules, P chest radiography for all nodules (1.49-fold, P chest radiography, as given by the area under the receiver operating characteristic curve (1.23-fold, P chest radiography or tomosynthesis. Conclusion Tomosynthesis outperformed conventional chest radiography for lung nodule detection and determination of case management; DE imaging did not show significant differences over conventional chest

  12. Computer-aided diagnosis of lung cancer: the effect of training data sets on classification accuracy of lung nodules

    Science.gov (United States)

    Gong, Jing; Liu, Ji-Yu; Sun, Xi-Wen; Zheng, Bin; Nie, Sheng-Dong

    2018-02-01

    This study aims to develop a computer-aided diagnosis (CADx) scheme for classification between malignant and benign lung nodules, and also assess whether CADx performance changes in detecting nodules associated with early and advanced stage lung cancer. The study involves 243 biopsy-confirmed pulmonary nodules. Among them, 76 are benign, 81 are stage I and 86 are stage III malignant nodules. The cases are separated into three data sets involving: (1) all nodules, (2) benign and stage I malignant nodules, and (3) benign and stage III malignant nodules. A CADx scheme is applied to segment lung nodules depicted on computed tomography images and we initially computed 66 3D image features. Then, three machine learning models namely, a support vector machine, naïve Bayes classifier and linear discriminant analysis, are separately trained and tested by using three data sets and a leave-one-case-out cross-validation method embedded with a Relief-F feature selection algorithm. When separately using three data sets to train and test three classifiers, the average areas under receiver operating characteristic curves (AUC) are 0.94, 0.90 and 0.99, respectively. When using the classifiers trained using data sets with all nodules, average AUC values are 0.88 and 0.99 for detecting early and advanced stage nodules, respectively. AUC values computed from three classifiers trained using the same data set are consistent without statistically significant difference (p  >  0.05). This study demonstrates (1) the feasibility of applying a CADx scheme to accurately distinguish between benign and malignant lung nodules, and (2) a positive trend between CADx performance and cancer progression stage. Thus, in order to increase CADx performance in detecting subtle and early cancer, training data sets should include more diverse early stage cancer cases.

  13. The diagnosis of small solitary pulmonary nodule: comparison of standard and inverse digital images on a high resolution monitor using ROC analysis

    International Nuclear Information System (INIS)

    Choi, Byeong Kyoo; Lee, In Sun; Seo, Joon Beom; Lee, Jin Seong; Song, Koun Sik; Lim, Tae Hwan

    2002-01-01

    To study the impact of inversion of soft-copy chest radiographs on the detection of small solitary pulmonary nodules using a high-resolution monitor. The study group consisted of 80 patients who had undergone posterior chest radiography; 40 had a solitary noncalcified pulmonary nodule approximately 1 cm in diameter, and 40 were control subjects. Standard and inverse digital images using the inversion tool on a PACS system were displayed on high-resolution monitors (2048x2560x8 bit). Ten radiologists were requested to rank each image using a five-point scale (1=definitely negative, 3=equivocal or indeterminate, 5=definite nodule), and the data were interpreted using receiver operating characteristic (ROC) analysis. The area under the ROC curve for pooled data of standard image sets was significantly larger than that of inverse image sets (0.8893 and 0.8095, respectively; p 0.05). For detecting small solitary pulmonary nodules, inverse digital images were significantly inferior to standard digital images