WorldWideScience

Sample records for benching

  1. Influence of bench angle on upper extremity muscular activation during bench press exercise.

    Science.gov (United States)

    Lauver, Jakob D; Cayot, Trent E; Scheuermann, Barry W

    2016-01-01

    This study compared the muscular activation of the pectoralis major, anterior deltoid and triceps brachii during a free-weight barbell bench press performed at 0°, 30°, 45° and -15° bench angles. Fourteen healthy resistance trained males (age 21.4 ± 0.4 years) participated in this study. One set of six repetitions for each bench press conditions at 65% one repetition maximum were performed. Surface electromyography (sEMG) was utilised to examine the muscular activation of the selected muscles during the eccentric and concentric phases. In addition, each phase was subdivided into 25% contraction durations, resulting in four separate time points for comparison between bench conditions. The sEMG of upper pectoralis displayed no difference during any of the bench conditions when examining the complete concentric contraction, however differences during 26-50% contraction duration were found for both the 30° [122.5 ± 10.1% maximal voluntary isometric contraction (MVIC)] and 45° (124 ± 9.1% MVIC) bench condition, resulting in greater sEMG compared to horizontal (98.2 ± 5.4% MVIC) and -15 (96.1 ± 5.5% MVIC). The sEMG of lower pectoralis was greater during -15° (100.4 ± 5.7% MVIC), 30° (86.6 ± 4.8% MVIC) and horizontal (100.1 ± 5.2% MVIC) bench conditions compared to the 45° (71.9 ± 4.5% MVIC) for the whole concentric contraction. The results of this study support the use of a horizontal bench to achieve muscular activation of both the upper and lower heads of the pectoralis. However, a bench incline angle of 30° or 45° resulted in greater muscular activation during certain time points, suggesting that it is important to consider how muscular activation is affected at various time points when selecting bench press exercises.

  2. Relationship of pectoralis major muscle size with bench press and bench throw performances.

    Science.gov (United States)

    Akagi, Ryota; Tohdoh, Yukihiro; Hirayama, Kuniaki; Kobayashi, Yuji

    2014-06-01

    This study examined the relationship of muscle size indices of the pectoralis major muscle with bench press and bench throw performances in 18 male collegiate athletes. The maximal cross-sectional area (MCSAMAx) and volume (MV) of the pectoralis major muscle were determined by magnetic resonance imaging. First, subjects were tested for their one repetition maximum bench press strength (1RMBP) using a Smith machine. At a later date, subjects performed bench throws using the Smith machine with several different loads ranging from 30.0 kg to 90% of 1RMBP. Barbell positions were measured by a linear position transducer, and bench throw power was calculated using a dynamic equation. Three trials were performed for each load. In all the trials, the maximal peak power was adopted as bench throw peak power (PPBT). The 1RMBP was significantly correlated with MCSAMAx. Similarly, the correlation coefficient between MV and PPBT was significant. In contrast to the y-intercept of the MV-PPBT regression line, that of the MCSAMAx-1RMBP regression line was not significantly different from 0. These results suggested that, although the dependence on pectoralis major muscle size is slightly different between bench press strength and bench throw power, the pectoralis major muscle size has a significant impact on bench press and throw performances. Greater muscle size leads to heavier body weight, which can be a negative factor in some sports. We therefore recommend that athletes and their coaches develop training programs for improving sports performance by balancing the advantage of increased muscle size and the potential disadvantage of increased body weight.

  3. Kinematics and kinetics of the bench-press and bench-pull exercises in a strength-trained sporting population.

    Science.gov (United States)

    Pearson, Simon N; Cronin, John B; Hume, Patria A; Slyfield, David

    2009-09-01

    Understanding how loading affects power production in resistance training is a key step in identifying the most optimal way of training muscular power - an essential trait in most sporting movements. Twelve elite male sailors with extensive strength-training experience participated in a comparison of kinematics and kinetics from the upper body musculature, with upper body push (bench press) and pull (bench pull) movements performed across loads of 10-100% of one repetition maximum (1RM). 1RM strength and force were shown to be greater in the bench press, while velocity and power outputs were greater for the bench pull across the range of loads. While power output was at a similar level for the two movements at a low load (10% 1RM), significantly greater power outputs were observed for the bench pull in comparison to the bench press with increased load. Power output (Pmax) was maximized at higher relative loads for both mean and peak power in the bench pull (78.6 +/- 5.7% and 70.4 +/- 5.4% of 1RM) compared to the bench press (53.3 +/- 1.7% and 49.7 +/- 4.4% of 1RM). Findings can most likely be attributed to differences in muscle architecture, which may have training implications for these muscles.

  4. Astrophysics on the Lab Bench

    Science.gov (United States)

    Hughes, Stephen W.

    2010-01-01

    In this article some basic laboratory bench experiments are described that are useful for teaching high school students some of the basic principles of stellar astrophysics. For example, in one experiment, students slam a plastic water-filled bottle down onto a bench, ejecting water towards the ceiling, illustrating the physics associated with a…

  5. Distal clavicular osteolysis in adults: association with bench pressing intensity

    International Nuclear Information System (INIS)

    Nevalainen, Mika T.; Morrison, William B.; Zoga, Adam C.; Roedl, Johannes B.; Ciccotti, Michael G.

    2016-01-01

    To investigate the association between distal clavicular osteolysis (DCO) and bench pressing intensity. From a retrospective review of MRI shoulder reports of individuals between 20 and 40 years of age, 262 male patients with DCO and 227 age-matched male patients without DCO were selected. All patients had completed a bench pressing questionnaire. The patients' bench pressing frequency (times per week), duration (years of bench pressing), bench pressing weight (maximum bench pressing weight with one repetition = 1RM) and the ratio of bench pressing weight to body weight were compared between both groups using Chi-square and Mann-Whitney tests. The results showed that 56 % (146/262) of patients with DCO were high-intensity bench pressers (1RM more than 1.5 times the body weight) compared to 6 % (14/227) in patients without DCO. High-intensity bench pressing was a risk factor for DCO (OR = 19; 95 %CI = 11-35; p 1 x /week) and duration (>5 years) of bench pressing were risk factors. In bench pressers who suffered from DCO, the mean 1RM was 283 lbs (±SD 57) compared to 209 lbs (±SD 60) in bench pressers not affected by DCO (p < 0.001, Mann-Whitney). High-intensity, but not low-intensity bench pressing is a risk factor for DCO. (orig.)

  6. Distal clavicular osteolysis in adults: association with bench pressing intensity

    Energy Technology Data Exchange (ETDEWEB)

    Nevalainen, Mika T.; Morrison, William B.; Zoga, Adam C.; Roedl, Johannes B. [Sidney Kimmel Medical College at Thomas Jefferson University, Division of Musculoskeletal Imaging and Interventions, Department of Radiology, Thomas Jefferson University Hospital, Philadelphia, PA (United States); Ciccotti, Michael G. [Sidney Kimmel Medical College at Thomas Jefferson University, Division of Sports Medicine, Department of Orthopedic Surgery, Thomas Jefferson University Hospital, Rothman Institute, Philadelphia, PA (United States)

    2016-11-15

    To investigate the association between distal clavicular osteolysis (DCO) and bench pressing intensity. From a retrospective review of MRI shoulder reports of individuals between 20 and 40 years of age, 262 male patients with DCO and 227 age-matched male patients without DCO were selected. All patients had completed a bench pressing questionnaire. The patients' bench pressing frequency (times per week), duration (years of bench pressing), bench pressing weight (maximum bench pressing weight with one repetition = 1RM) and the ratio of bench pressing weight to body weight were compared between both groups using Chi-square and Mann-Whitney tests. The results showed that 56 % (146/262) of patients with DCO were high-intensity bench pressers (1RM more than 1.5 times the body weight) compared to 6 % (14/227) in patients without DCO. High-intensity bench pressing was a risk factor for DCO (OR = 19; 95 %CI = 11-35; p < 0.001). Low-intensity bench pressing (1RM less than 1.5 times the body weight) was not a risk factor for DCO (OR = 0.6; 95 % CI = 0.4-0.8). High frequency (>1 x /week) and duration (>5 years) of bench pressing were risk factors. In bench pressers who suffered from DCO, the mean 1RM was 283 lbs (±SD 57) compared to 209 lbs (±SD 60) in bench pressers not affected by DCO (p < 0.001, Mann-Whitney). High-intensity, but not low-intensity bench pressing is a risk factor for DCO. (orig.)

  7. RemBench: A Digital Workbench for Rembrandt Research

    NARCIS (Netherlands)

    Verberne, Suzan; Van Leeuwen, Rudie; Gerritsen, G.H.; Boves, Lou

    2016-01-01

    In this paper, we present RemBench, a search engine for research into the life and works of Rembrandt van Rijn. RemBench combines the data from four different databases behind one interface using federated search technology. Metadata filtering is enabled through faceted search. RemBench enables art

  8. Elbow joint fatigue and bench-press training.

    Science.gov (United States)

    Huang, Yen-Po; Chou, You-Li; Chen, Feng-Chun; Wang, Rong-Tyai; Huang, Ming-Jer; Chou, Paul Pei-Hsi

    2014-01-01

    Bench-press exercises are among the most common form of training exercise for the upper extremity because they yield a notable improvement in both muscle strength and muscle endurance. The literature contains various investigations into the effects of different bench-press positions on the degree of muscle activation. However, the effects of fatigue on the muscular performance and kinetics of the elbow joint are not understood fully. To investigate the effects of fatigue on the kinetics and myodynamic performance of the elbow joint in bench-press training. Controlled laboratory study. Motion research laboratory. A total of 18 physically healthy male students (age = 19.6 ± 0.8 years, height = 168.7 ± 5.5 cm, mass = 69.6 ± 8.6 kg) participated in the investigation. All participants were right-hand dominant, and none had a history of upper extremity injuries or disorders. Participants performed bench-press training until fatigued. Maximal possible number of repetitions, cycle time, myodynamic decline rate, elbow-joint force, and elbow-joint moment. We observed a difference in cycle time in the initial (2.1 ± 0.42 seconds) and fatigue (2.58 ± 0.46 seconds) stages of the bench-press exercise (P = .04). As the participants fatigued, we observed an increase in the medial-lateral force (P = .03) and internal-external moment (P ≤ .04) acting on the elbow joint. Moreover, a reduction in the elbow muscle strength was observed in the elbow extension-flexion (P ≤ .003) and forearm supination-pronation (P ≤ .001) conditions. The results suggest that performing bench-press exercises to the point of fatigue increases elbow-joint loading and may further increase the risk of injury. Therefore, when clinicians design bench-press exercise regimens for general athletic training, muscle strengthening, or physical rehabilitation, they should control carefully the maximal number of repetitions.

  9. Influence of the "Slingshot" bench press training aid on bench press kinematics and neuromuscular activity in competitive powerlifters.

    Science.gov (United States)

    Dugdale, James H; Hunter, Angus; Di Virgilio, Thomas; Macgregor, Lewis J; Hamilton, D Lee

    2017-02-13

    This study examined the acute effects of the 'Slingshot' on bench-press performance, prime-mover surface electromyographic (sEMG) amplitude, and barbell velocity during maximal and submaximal bench-pressing in competitive male powerlifters. Fifteen male powerlifters (mean ± SD age: 27.05 ± 5.94 years; mass: 94.15kg; 1RM bench-press: 139.7 ± 16.79kg) participated in the study. Bench-press strength, average barbell velocity, and sEMG amplitude of the prime mover muscles (triceps brachii, pectoralis major and anterior deltoid) were measured during two conditions; 'Raw' (without use of any assistance) and 'Slingshot' [using the 'Slingshot' to perform both the weight achieved during 'Raw' 1RM testing (Raw max/SS), and absolute 1RM using the 'Slingshot' (SS)]. The results showed that the 'Slingshot' significantly increased bench press 1RM performance by a mean ± SD of 20.67kg ± 3.4kg. Barbell velocity and stick point analysis indicate that this improvement is likely driven by an increase in peak and pre-stick barbell velocity as triceps RMS was lower throughout all rep max phases with the 'Slingshot'. The 'Slingshot' also caused reductions in RMS, specifically of the triceps at all rep ranges but barbell velocity was better maintained in the last reps of all sets. These data indicate that the 'Slingshot' specifically de-loaded the triceps muscle throughout all rep ranges and provide assistance to maintaining barbell velocity under fatigue during later repetitions of multiple-repetition sets. The 'Slingshot' training aid could therefore be used in de-load phases of bench press training or as an over-reaching and velocity training aid.

  10. Comparison of Myoelectric Activity of a Selection of Upper Extremity Muscles while Doing Bench Press in Two Training Methods of TRX and Barbell Bench Press

    Directory of Open Access Journals (Sweden)

    Ahmad Reza Zibaei

    2016-12-01

    Conclusion: Considering these results it can be maintained that TRX bench press resistance training can be an alternative and effective practice for barbell bench press because, given the results, it can be appreciated that TRX bench press, dips low in the trunk, can lead to muscle activity close to the level of muscle activity during the barbell bench press drill.

  11. ESPRESSO optical bench: from mind to reality

    Science.gov (United States)

    Tenegi, F.; Santana, S.; Gómez, J.; Rodilla, E.; Hughes, I.; Mégevand, D.; Rebolo, R.; Riva, M.; Luis-Simoes, R.

    2016-07-01

    ESPRESSO [1] is a high-resolution spectrograph under development for the VLT telescope. In general, the Optical Bench (OB) structure can be considered as a 3D one, conformed by welding thin plates of Structural Steel (St-52) with a nickelplated surface treatment, combined for getting maximum stiffness and minimum weight, that will be finally re-machined to get stringent geometrical and dimensional tolerances at I/Fs positions. TIG conventional welding procedure has been selected to minimize the cost and facilitate the own welding process. This solution follows the inheritance from HARPS [2] due to its success to achieve the required performance for the bench. This paper contains an overview of the whole process of designing and manufacturing the Optical Bench of ESPRESSO, from the very first beginning with the specifications to the current status of the bench with its integration on the Spectrograph (including the Finite Element Models and the delivery of the final structure by the supplier) and lessons learned.

  12. Bench-marking beam-beam simulations using coherent quadrupole effects

    International Nuclear Information System (INIS)

    Krishnagopal, S.; Chin, Y.H.

    1992-06-01

    Computer simulations are used extensively in the study of the beam-beam interaction. The proliferation of such codes raises the important question of their reliability, and motivates the development of a dependable set of bench-marks. We argue that rather than detailed quantitative comparisons, the ability of different codes to predict the same qualitative physics should be used as a criterion for such bench-marks. We use the striking phenomenon of coherent quadrupole oscillations as one such bench-mark, and demonstrate that our codes do indeed observe this behaviour. We also suggest some other tests that could be used as bench-marks

  13. Bench-marking beam-beam simulations using coherent quadrupole effects

    International Nuclear Information System (INIS)

    Krishnagopal, S.; Chin, Y.H.

    1992-01-01

    Computer simulations are used extensively in the study of the beam-beam interaction. The proliferation of such codes raises the important question of their reliability, and motivates the development of a dependable set of bench-marks. We argue that rather than detailed quantitative comparisons, the ability of different codes to predict the same qualitative physics should be used as a criterion for such bench-marks. We use the striking phenomenon of coherent quadrupole oscillations as one such bench-mark, and demonstrate that our codes do indeed observe this behavior. We also suggest some other tests that could be used as bench-marks

  14. A Methodology for Reducing Bench Strength in Information Technology Companies

    Directory of Open Access Journals (Sweden)

    Boby John

    2015-07-01

    Full Text Available One of the major risks in information technology (IT project execution is the non-availability of resources with required skill sets to meet the project demands. To mitigate this risk, almost every IT organization maintains a portion of their resources on bench. The bench strength reduces the delay in starting the project due to the non-availability of skilled resources. But bench strength or buffer is cost to the company. A medium scale Indian IT company incurs around USD 142,347 monthly on maintaining the bench strength. Hence this study is undertaken to develop a methodology to reduce the bench strength in IT companies. The proposed methodology is to obtain an optimum mix of resources from bench and through recruitment to meet the demands at a minimum cost. This is done by formulating the problem as an integer programming problem. The problem aims to minimize the total cost of obtaining the skilled resources without violating the constraints on demand, bench strength availability and recruitment lead time. The problem can be solved using Microsoft excel solver function or any other optimization packages like CPLEX, Gurobi, etc. A case study on the application of proposed methodology is also discussed in the paper. The case study showed that the proposed methodology is superior to the existing practice of maintaining large bench strengths to meet the demands for resources with various skills.

  15. Bench for mechanical cleaning of circular welded joints

    International Nuclear Information System (INIS)

    Sklifasovskij, V.M.

    1986-01-01

    A special bench for weld reinforcement removal and mechanical cleaning of the heat affected zones was designed to provide for a possibility of an ultrasonic testing of welded joints in the course of steam generator section fabrication. The bench comprises a mechanized roller support for fixing and rotating the workpiece; a lap-cutting device for external machining; milling/grinding tractor for internal machining and a delivery table for tractor approach and departure. The bench performance and overall view are presented. The operation succession is described

  16. Movement Features Which Describe the Flat Bench Press

    Directory of Open Access Journals (Sweden)

    Król Henryk

    2017-06-01

    Full Text Available Introduction. In sport technique studies, motion features can be useful as they have a certain defined measure [1]. In this work, we examined the following three features: the structure of the movement (all the characteristics of the movement, the fluency of the movement, and the rhythm of the movement. The aim of the study was to determine the usefulness of the selected movement features in the evaluation of the flat bench press. The protocol of the study included a flat bench press with free weights and a “touch-and-go” technique. Material and methods. The study involved twenty healthy men; however, only two were selected for analysis. The first subject was a 25-year-old powerlifter (body mass = 95 kg; body height = 182 cm; 1-RM in flat bench press = 145 kg. The second one was a 25-year-old bodybuilder (body mass = 77 kg; body height = 175 cm; 1-RM in flat bench press = 100 kg. The subjects performed consecutive sets of a single repetition of flat bench pressing with an increasing load (70, 80, 90, and 100% 1-RM, with the anticipated maximum weight, until the completion of one repetition maximum. Multidimensional movement analysis was made with the measuring system Smart-E (BTS, Italy, which consisted of six infrared cameras (120 Hz and a wireless module to measure muscle bioelectric activity (Pocket EMG. Results. It was demonstrated that the internal structure of the bench press performed by the bodybuilder and the powerlifter was different. As the time-history of barbell kinematics (the acceleration-time curve showed, with increased loading of the barbell, the rhythm of the flat bench press changed, and the fluidity of the movement worsened.

  17. Test Bench Development for Femur Stability Assessment

    Directory of Open Access Journals (Sweden)

    Samuel SANCHEZ-CABALLERO

    2015-01-01

    Full Text Available This paper shows the design and development of a test bench for humanfemurs. The main uses of this test bench will run from artificial femurs comparisonwith real femurs, to join stability assessment after bone a fracture repair. Amongthis uses is specially designed for condylar fractures testing. The test bench isdeveloped from a self-made existing tensile/compression testing machine. Thedesign procedure is supported by a literature review about the bone mechanicalbehavior and composition generally and the knee joint performance and repairparticularly. On the basis of this review, the machine was designed to simulate theadduction and abduction movements of the joint. The magnitudes to be measuredare: the compression force, the bone displacement (vertical and the knee jointrotation

  18. Cost-benefit of bench terraces, a case study in Peru

    NARCIS (Netherlands)

    Posthumus, H.; Graaff, de J.

    2005-01-01

    Soil and water conservation measures like bench terraces can reduce erosion in highland crop production. A cost-benefit analysis for 11 cases of bench terraces was undertaken on the basis of both measured data and data obtained from farmers. It showed that the profitability of bench terraces was

  19. The national hydrologic bench-mark network

    Science.gov (United States)

    Cobb, Ernest D.; Biesecker, J.E.

    1971-01-01

    The United States is undergoing a dramatic growth of population and demands on its natural resources. The effects are widespread and often produce significant alterations of the environment. The hydrologic bench-mark network was established to provide data on stream basins which are little affected by these changes. The network is made up of selected stream basins which are not expected to be significantly altered by man. Data obtained from these basins can be used to document natural changes in hydrologic characteristics with time, to provide a better understanding of the hydrologic structure of natural basins, and to provide a comparative base for studying the effects of man on the hydrologic environment. There are 57 bench-mark basins in 37 States. These basins are in areas having a wide variety of climate and topography. The bench-mark basins and the types of data collected in the basins are described.

  20. HEV Test Bench Based on CAN Bus Sensor Communication

    Directory of Open Access Journals (Sweden)

    Shupeng ZHAO

    2014-02-01

    Full Text Available The HEV test bench based on Controller Area Network bus was studied and developed. Control system of HEV power test bench used the CAN bus technology. The application of CAN bus technology on control system development has opened up a new research direction for domestic automobile experimental platform. The HEV power control system development work was completed, including power master controller, electric throttle controller, driving simulation platform, CAN2.0 B communication protocol procedures for formulation, CAN communication monitoring system, the simulation model based on MATLAB code automatic generation technology research, etc. Maximum absorption power of the test bench is 90 kW, the test bench top speed is 6000 r/min, the CAN communication data baud rate is 10~500 k, the conventional electric measurement parameter part precision satisfies the requirement of development of HEV. On the HEV test bench the result of regenerative braking experiment shows that the result got by the test bench was closer to the results got by outdoor road test. And the fuel consumption experiment test results show that the HEV fuel consumption and the charge-discharge character are in linear relationship. The establishment of the test platform for the evaluation of the development of hybrid electric vehicle and power provides physical simulation and test platform.

  1. BENCH SCALE SALTSTONE PROCESS DEVELOPMENT MIXING STUDY

    Energy Technology Data Exchange (ETDEWEB)

    Cozzi, A.; Hansen, E.

    2011-08-03

    The Savannah River National Laboratory (SRNL) was requested to develop a bench scale test facility, using a mixer, transfer pump, and transfer line to determine the impact of conveying the grout through the transfer lines to the vault on grout properties. Bench scale testing focused on the effect the transfer line has on the rheological property of the grout as it was processed through the transfer line. Rheological and other physical properties of grout samples were obtained prior to and after pumping through a transfer line. The Bench Scale Mixing Rig (BSMR) consisted of two mixing tanks, grout feed tank, transfer pump and transfer hose. The mixing tanks were used to batch the grout which was then transferred into the grout feed tank. The contents of the feed tank were then pumped through the transfer line (hose) using a progressive cavity pump. The grout flow rate and pump discharge pressure were monitored. Four sampling stations were located along the length of the transfer line at the 5, 105 and 205 feet past the transfer pump and at 305 feet, the discharge of the hose. Scaling between the full scale piping at Saltstone to bench scale testing at SRNL was performed by maintaining the same shear rate and total shear at the wall of the transfer line. The results of scaling down resulted in a shorter transfer line, a lower average velocity, the same transfer time and similar pressure drops. The condition of flow in the bench scale transfer line is laminar. The flow in the full scale pipe is in the transition region, but is more laminar than turbulent. The resulting plug in laminar flow in the bench scale results in a region of no-mixing. Hence mixing, or shearing, at the bench scale should be less than that observed in the full scale, where this plug is non existent due to the turbulent flow. The bench scale tests should be considered to be conservative due to the highly laminar condition of flow that exists. Two BSMR runs were performed. In both cases, wall

  2. The Effects of Bench Press Variations in Competitive Athletes on Muscle Activity and Performance.

    Science.gov (United States)

    Saeterbakken, Atle Hole; Mo, Dag-André; Scott, Suzanne; Andersen, Vidar

    2017-06-01

    The aim of the study was to compare the EMG activity performing 6RM competition style bench press (flat bench-wide grip) with 1) medium and narrow grip widths on a flat bench and 1) inclined and declined bench positions with a wide grip. Twelve bench press athletes competing at national and international level participated in the study. EMG activity was measured in the pectoralis major, anterior and posterior deltoid, biceps brachii, triceps brachii and latissimus dorsi. Non-significant differences in activation were observed between the three bench positions with the exception of 58.5-62.6% lower triceps brachii activation, but 48.3-68.7% greater biceps brachii activation in the inclined bench compared with the flat and declined bench position. Comparing the three grip widths, non-significant differences in activations were observed, with the exception of 25.9-30.5% lower EMG activity in the biceps brachii using a narrow grip, compared to the medium and wide grip conditions. The 6-RM loads were 5.8-11.1% greater using a medium and wide grip compared to narrow grip width and 18.5-21.5% lower in the inclined bench position compared with flat and declined. Comparing the EMG activity during the competition bench press style with either the inclined and declined bench position (wide grip) or using a narrow and medium grip (flat bench), only resulted in different EMG activity in the biceps- and triceps brachii. The 6RM loads varied with each bench press variation and we recommend the use of a wide grip on a flat bench during high load hypertrophy training to bench press athletes.

  3. Calibration bench of flowmeters

    International Nuclear Information System (INIS)

    Bremond, J.; Da Costa, D.; Calvet, A.; Vieuxmaire, C.

    1966-01-01

    This equipment is devoted to the comparison of signals from two turbines installed in the Cabri experimental loop. The signal is compared to the standard turbine. The characteristics and the performance of the calibration bench are presented. (A.L.B.)

  4. SP2Bench: A SPARQL Performance Benchmark

    Science.gov (United States)

    Schmidt, Michael; Hornung, Thomas; Meier, Michael; Pinkel, Christoph; Lausen, Georg

    A meaningful analysis and comparison of both existing storage schemes for RDF data and evaluation approaches for SPARQL queries necessitates a comprehensive and universal benchmark platform. We present SP2Bench, a publicly available, language-specific performance benchmark for the SPARQL query language. SP2Bench is settled in the DBLP scenario and comprises a data generator for creating arbitrarily large DBLP-like documents and a set of carefully designed benchmark queries. The generated documents mirror vital key characteristics and social-world distributions encountered in the original DBLP data set, while the queries implement meaningful requests on top of this data, covering a variety of SPARQL operator constellations and RDF access patterns. In this chapter, we discuss requirements and desiderata for SPARQL benchmarks and present the SP2Bench framework, including its data generator, benchmark queries and performance metrics.

  5. System of Thermal Balance Maintenance in Modern Test Benches for Centrifugal Pumps

    Directory of Open Access Journals (Sweden)

    A. I. Petrov

    2015-01-01

    Full Text Available The article “Systems of the heat balance maintenance in modern test benches for centrifugal pumps” makes the case to include cooling systems of a working fluid (heat setting in test bench for impeller pumps. It briefly summarizes an experience of bench building to test centrifugal pumps, developed at the BMSTU Department E-10 over the last 10 years. The article gives the formulas and the algorithm to calculate the heat capacity of different types of impeller pumps when tested at the bench as ell as to determine the heating time of the liquid in the bench without external cooling. Based on analysis of the power balance of a centrifugal pump, it is shown that about 90% of the pump unit-consumed electric power in terminals is used for heating up the working fluid in the loop of the test bench. The article gives examples of elementary heat calculation of the pump operation within the test bench. It presents the main types of systems to maintain thermal balance, their advantages, disadvantages and possible applications. The cooling system schemes for open and closed version of the benches both with built-in and with an independent cooling circuit are analysed. The paper separately considers options of such systems for large benches using the cooling tower as a cooling device in the loop, and to test the pumps using the hydraulic fluids other than water, including those at high temperatures of working fluids; in the latter case a diagram of dual-circuit cooling system "liquid-liquid-air" is shown. The paper depicts a necessity to use ethylene glycol coolant in the two-loop cooling bench. It provides an example of combining the functions of cooling and filtration in a single cooling circuit. Criteria for effectiveness of these systems are stated. Possible ways for developing systems to maintain a thermal balance, modern methods of regulation and control are described. In particular, the paper shows the efficiency of frequency control of the

  6. A comparison of muscle activation between a Smith machine and free weight bench press.

    Science.gov (United States)

    Schick, Evan E; Coburn, Jared W; Brown, Lee E; Judelson, Daniel A; Khamoui, Andy V; Tran, Tai T; Uribe, Brandon P

    2010-03-01

    The bench press exercise exists in multiple forms including the machine and free weight bench press. It is not clear though how each mode differs in its effect on muscle activation. The purpose of this study was to compare muscle activation of the anterior deltoid, medial deltoid, and pectoralis major during a Smith machine and free weight bench press at lower (70% 1 repetition maximum [1RM]) and higher (90% 1RM) intensities. Normalized electromyography amplitude values were used during the concentric phase of the bench press to compare muscle activity between a free weight and Smith machine bench press. Participants were classified as either experienced or inexperienced bench pressers. Two testing sessions were used, each of which entailed either all free weight or all Smith machine testing. In each testing session, each participant's 1RM was established followed by 2 repetitions at 70% of 1RM and 2 repetitions at 90% of 1RM. Results indicated greater activation of the medial deltoid on the free weight bench press than on the Smith machine bench press. Also, there was greater muscle activation at the 90% 1RM load than at the 70% 1RM load. The results of this study suggest that strength coaches should consider choosing the free weight bench press over the Smith machine bench press because of its potential for greater upper-body muscular development.

  7. Direction-specific recruitment of rotator cuff muscles during bench press and row.

    Science.gov (United States)

    Wattanaprakornkul, Duangjai; Halaki, Mark; Cathers, Ian; Ginn, Karen A

    2011-12-01

    Recent studies indicate that rotator cuff (RC) muscles are recruited in a reciprocal, direction-specific pattern during shoulder flexion and extension exercises. The main purpose of this study was to determine if similar reciprocal RC recruitment occurs during bench press (flexion-like) and row (extension-like) exercises. In addition, shoulder muscle activity was comprehensively compared between bench press and flexion; row and extension; and bench press and row exercises. Electromyographic (EMG) activity was recorded from 9 shoulder muscles sites in 15 normal volunteers. All exercises were performed at 20, 50 and 70% of subjects' maximal load. EMG data were normalized to standard maximal voluntary contractions. Infraspinatus activity was significantly higher than subscapularis during bench press, with the converse pattern during the row exercise. Significant differences in activity levels were found in pectoralis major, deltoid and trapezius between the bench press and flexion exercises and in lower trapezius between the row and extension exercises. During bench press and row exercises, the recruitment pattern in each active muscle did not vary with load. During bench press and row exercises, RC muscles contract in a reciprocal direction-specific manner in their role as shoulder joint dynamic stabilizers to counterbalance antero-posterior translation forces. Copyright © 2011 Elsevier Ltd. All rights reserved.

  8. The Effects of Bench Press Variations in Competitive Athletes on Muscle Activity and Performance

    OpenAIRE

    Saeterbakken, Atle Hole; Mo, Dag-Andr?; Scott, Suzanne; Andersen, Vidar

    2017-01-01

    Abstract The aim of the study was to compare the EMG activity performing 6RM competition style bench press (flat bench-wide grip) with 1) medium and narrow grip widths on a flat bench and 1) inclined and declined bench positions with a wide grip. Twelve bench press athletes competing at national and international level participated in the study. EMG activity was measured in the pectoralis major, anterior and posterior deltoid, biceps brachii, triceps brachii and latissimus dorsi. Non-signific...

  9. Test benches for studying the properties of car tyres

    Science.gov (United States)

    Kuznetsov, N. Yu.; Fedotov, A. I.; Vlasov, V. G.

    2017-12-01

    The article describes the design of the measuring systems of test benches used to study the properties of elastic tyres. The bench has two autonomous systems - for testing the braking properties of elastic tyres rolling in a plane parallel way and for testing tyre slip properties. The system for testing braking properties determines experimental characteristics of elastic tyres as the following dependencies: longitudinal response vs time, braking torque vs slip, angular velocity vs slip, and longitudinal response vs slip. The system for studying tyre slip properties determines both steady (dependence of the lateral response in a contact area on the slipping angle) and non-steady characteristics (time variation of the slipping angle as a result of turning from -40 to +40 degrees) of tyre slip. The article presents the diagrams of bench tests of elastic tyres. The experimental results show metrological parameters and functional capabilities of the bench for studying tyre properties in driving and braking modes. The metrological indices of the recorded parameters of the measuring system for studying tyre properties are presented in the table.

  10. Test bench for measurements of NOvA scintillator properties at JINR

    Science.gov (United States)

    Velikanova, D. S.; Antoshkin, A. I.; Anfimov, N. V.; Samoylov, O. B.

    2018-04-01

    The NOvA experiment was built to study oscillation parameters, mass hierarchy, CP- violation phase in the lepton sector and θ23 octant, via vɛ appearance and vμ disappearance modes in both neutrino and antineutrino beams. These scientific goals require good knowledge about NOvA scintillator basic properties. The new test bench was constructed and upgraded at JINR. The main goal of this bench is to measure scintillator properties (for solid and liquid scintillators), namely α/β discrimination and Birk's coefficients for protons and other hadrons (quenching factors). This knowledge will be crucial for recovering the energy of the hadronic part of neutrino interactions with scintillator nuclei. α/β discrimination was performed on the first version of the bench for LAB-based and NOvA scintillators. It was performed again on the upgraded version of the bench with higher statistic and precision level. Preliminary result of quenching factors for protons was obtained. A technical description of both versions of the bench and current results of the measurements and analysis are presented in this work.

  11. Simulation of Induction Traction Drive with Supercapacitor Energy Storage System Test Bench

    Directory of Open Access Journals (Sweden)

    Stana Girts

    2015-12-01

    Full Text Available The paper describes the application of supercapacitor energy storage system for induction traction drive test bench that replaces a real electric public transport for performing testing and researches. The suitability and usage of such bench for research purposes is explained and the importance of the development of software mathematical model for performing simulations to be done before physical implementation measures is reasoned. The working principle of the bench and applied components are described. A virtual model of the bench was built and simulations were performed using Matlab/Simulink software. The basic topology of the virtual bench model is described as well. The calculations of this work show the scaling of supercapacitor energy storage system by setting different limits of working voltage range in order to adjust them to test bench parameters, whereas the modelling compares two simulation cases – the application of less supercapacitors and the application of more supercapacitors with the same common rated voltage. The autonomous mode simulations were also performed. Simulation results are analyzed and recommendations for the application of the supercapacitor energy storage system, with respect to initial supercapacitor circuit voltage, are given.

  12. Using bench press load to predict upper body exercise loads in physically active individuals.

    Science.gov (United States)

    Wong, Del P; Ngo, Kwan-Lung; Tse, Michael A; Smith, Andrew W

    2013-01-01

    This study investigated whether loads for assistance exercises of the upper body can be predicted from the loads of the bench press exercise. Twenty-nine physically active collegiate students (age: 22.6 ± 2.5; weight training experience: 2.9 ± 2.1 years; estimated 1RM bench press: 54.31 ± 14.60 kg; 1RM: body weight ratio: 0.80 ± 0.22; BMI: 22.7 ± 2.1 kg·m(-2)) were recruited. The 6RM loads for bench press, barbell bicep curl, overhead dumbbell triceps extension, hammer curl and dumbbell shoulder press were measured. Test-retest reliability for the 5 exercises as determined by Pearson product moment correlation coefficient was very high to nearly perfect (0.82-0.98, p bench press load was significantly correlated with the loads of the 4 assistance exercises (r ranged from 0.80 to 0.93, p bench press load was a significant (R(2) range from 0.64 to 0.86, p Bench press load (0.28) + 6.30 kg, (b) Barbell biceps curl = Bench press load (0.33) + 6.20 kg, (c) Overhead triceps extension = Bench press load (0.33) - 0.60 kg, and (d) Dumbbell shoulder press = Bench press load (0.42) + 5.84 kg. The difference between the actual load and the predicted load using the four equations ranged between 6.52% and 8.54%, such difference was not significant. Fitness professionals can use the 6RM bench press load as a time effective and accurate method to predict training loads for upper body assistance exercises. Key pointsThe bench press load was significantly correlated with the loads of the 4 assistance exercises.No significant differences were found between the actual load and the predicted load in the four equations.6RM bench press load can be a time effective and accurate method to predict training loads for upper body assistance exercises.

  13. A PMT-Block test bench

    International Nuclear Information System (INIS)

    Adragna, P.; Antonaki, A.

    2006-01-01

    The front-end electronics of the ATLAS hadronic calorimeter (Tile Cal) is housed in a unit, called PMT-Block. The PMT-Block is a compact instrument comprising a light mixer, a PMT together with its divider and a 3-in-1 card, which provides shaping, amplification and integration for the signals. This instrument needs to be qualified before being assembled on the detector. A PMT-Block test bench has been developed for this purpose. This test bench is a system which allows fast, albeit accurate enough, measurements of the main properties of a complete PMT-Block. The system, both hardware and software, and the protocol used for the PMT-Blocks characterization are described in detail in this report. The results obtained in the test of about 10 000 PMT-Blocks needed for the instrumentation of the ATLAS (LHC-CERN) hadronic Tile Calorimeter are also reported

  14. A PMT-Block test bench

    Energy Technology Data Exchange (ETDEWEB)

    Adragna, P [Dipartimento di Fisica ' E.Fermi' , Universita di Pisa and Istituto Nazionale di Fisica Nucleare, Sezione di Pisa, Largo B. Pontecorvo 3, Pisa 56127 (Italy); Universita degli studi di Siena, via Roma 56, 53100 Siena (Italy); Antonaki, A [Institute of Accelerating Systems and Applications, P.O. Box 17214, Athens 10024 (Greece); National Capodistrian University of Athens, 30 Panepistimiou st., Athens 10679 (Greece)] (and others)

    2006-08-01

    The front-end electronics of the ATLAS hadronic calorimeter (Tile Cal) is housed in a unit, called PMT-Block. The PMT-Block is a compact instrument comprising a light mixer, a PMT together with its divider and a 3-in-1 card, which provides shaping, amplification and integration for the signals. This instrument needs to be qualified before being assembled on the detector. A PMT-Block test bench has been developed for this purpose. This test bench is a system which allows fast, albeit accurate enough, measurements of the main properties of a complete PMT-Block. The system, both hardware and software, and the protocol used for the PMT-Blocks characterization are described in detail in this report. The results obtained in the test of about 10 000 PMT-Blocks needed for the instrumentation of the ATLAS (LHC-CERN) hadronic Tile Calorimeter are also reported.

  15. A test-bench for measurement of electrical static parameters of strip silicon detectors

    International Nuclear Information System (INIS)

    Golutvin, I.A.; Dmitriev, A.Yu.; Elsha, V.V.

    2003-01-01

    An automated test-bench for electrical parameters input control of the strip silicon detectors, used in the End-Cap Preshower detector of the CMS experiment, is described. The test-bench application allows one to solve a problem of silicon detectors input control in conditions of mass production - 1800 detectors over 2 years. The test-bench software is realized in Delphi environment and contains a user-friendly operator interface for data processing and visualization as well as up-to-date facilities for MS-Windows used for the network database. High operating characteristics and reliability of the test-bench were confirmed while more than 800 detectors were tested. Some technical solutions applied to the test-bench could be useful for design and construction of automated facilities for electrical parameters measurements of the microstrip detectors input control. (author)

  16. A Test-Bench for Measurement of Electrical Static Parameters of Strip Silicon Detectors

    CERN Document Server

    Golutvin, I A; Danilevich, V G; Dmitriev, A Yu; Elsha, V V; Zamiatin, Y I; Zubarev, E V; Ziaziulia, F E; Kozus, V I; Lomako, V M; Stepankov, D V; Khomich, A P; Shumeiko, N M; Cheremuhin, A E

    2003-01-01

    An automated test-bench for electrical parameters input control of the strip silicon detectors, used in the End-Cap Preshower detector of the CMS experiment, is described. The test-bench application allows one to solve a problem of silicon detectors input control in conditions of mass production - 1800 detectors over 2 years. The test-bench software is realized in Delphi environment and contains a user-friendly operator interface for measurement data processing and visualization as well as up-to-date facilities for MS-Windows used for the network database. High operating characteristics and reliability of the test-bench were confirmed while more than 800 detectors were tested. Some technical solutions applied to the test-bench could be useful for design and construction of automated facilities for electrical parameters measurements of the microstrip detectors input control.

  17. Bench mark spectra for high-energy neutron dosimetry

    International Nuclear Information System (INIS)

    Dierckx, R.

    1986-01-01

    To monitor radiation damage experiments, activation detectors are commonly used. The precision of the results obtained by the multiple foil analysis is largely increased by the intercalibration in bench-mark spectra. This technique is already used in dosimetry measurements for fission reactors. To produce neutron spectra similar to fusion reactor and high-energy high-intensity neutron sources (d-Li or spallation), accelerators can be used. Some possible solutions as p-Be and d-D 2 O neutron sources, useful as bench-mark spectra are described. (author)

  18. Errors of car wheels rotation rate measurement using roller follower on test benches

    Science.gov (United States)

    Potapov, A. S.; Svirbutovich, O. A.; Krivtsov, S. N.

    2018-03-01

    The article deals with rotation rate measurement errors, which depend on the motor vehicle rate, on the roller, test benches. Monitoring of the vehicle performance under operating conditions is performed on roller test benches. Roller test benches are not flawless. They have some drawbacks affecting the accuracy of vehicle performance monitoring. Increase in basic velocity of the vehicle requires increase in accuracy of wheel rotation rate monitoring. It determines the degree of accuracy of mode identification for a wheel of the tested vehicle. To ensure measurement accuracy for rotation velocity of rollers is not an issue. The problem arises when measuring rotation velocity of a car wheel. The higher the rotation velocity of the wheel is, the lower the accuracy of measurement is. At present, wheel rotation frequency monitoring on roller test benches is carried out by following-up systems. Their sensors are rollers following wheel rotation. The rollers of the system are not kinematically linked to supporting rollers of the test bench. The roller follower is forced against the wheels of the tested vehicle by means of a spring-lever mechanism. Experience of the test bench equipment operation has shown that measurement accuracy is satisfactory at small rates of vehicles diagnosed on roller test benches. With a rising diagnostics rate, rotation velocity measurement errors occur in both braking and pulling modes because a roller spins about a tire tread. The paper shows oscillograms of changes in wheel rotation velocity and rotation velocity measurement system’s signals when testing a vehicle on roller test benches at specified rates.

  19. Bench-scale Kinetics Study of Mercury Reactions in FGD Liquors

    Energy Technology Data Exchange (ETDEWEB)

    Gary Blythe; John Currie; David DeBerry

    2008-03-31

    This document is the final report for Cooperative Agreement DE-FC26-04NT42314, 'Kinetics Study of Mercury Reactions in FGD Liquors'. The project was co-funded by the U.S. DOE National Energy Technology Laboratory and EPRI. The objective of the project has been to determine the mechanisms and kinetics of the aqueous reactions of mercury absorbed by wet flue gas desulfurization (FGD) systems, and develop a kinetics model to predict mercury reactions in wet FGD systems. The model may be used to determine optimum wet FGD design and operating conditions to maximize mercury capture in wet FGD systems. Initially, a series of bench-top, liquid-phase reactor tests were conducted and mercury species concentrations were measured by UV/visible light spectroscopy to determine reactant and byproduct concentrations over time. Other measurement methods, such as atomic absorption, were used to measure concentrations of vapor-phase elemental mercury, that cannot be measured by UV/visible light spectroscopy. Next, a series of bench-scale wet FGD simulation tests were conducted. Because of the significant effects of sulfite concentration on mercury re-emission rates, new methods were developed for operating and controlling the bench-scale FGD experiments. Approximately 140 bench-scale wet FGD tests were conducted and several unusual and pertinent effects of process chemistry on mercury re-emissions were identified and characterized. These data have been used to develop an empirically adjusted, theoretically based kinetics model to predict mercury species reactions in wet FGD systems. The model has been verified in tests conducted with the bench-scale wet FGD system, where both gas-phase and liquid-phase mercury concentrations were measured to determine if the model accurately predicts the tendency for mercury re-emissions. This report presents and discusses results from the initial laboratory kinetics measurements, the bench-scale wet FGD tests, and the kinetics modeling

  20. Association Between Maximal Bench Press Strength and Isometric Handgrip Strength Among Breast Cancer Survivors.

    Science.gov (United States)

    Rogers, Benjamin H; Brown, Justin C; Gater, David R; Schmitz, Kathryn H

    2017-02-01

    To characterize the relationship between 1-repetition maximum (1-RM) bench press strength and isometric handgrip strength among breast cancer survivors. Cross-sectional study. Laboratory. Community-dwelling breast cancer survivors (N=295). Not applicable. 1-RM bench press strength was measured with a barbell and exercise bench. Isometric handgrip strength was measured using an isometric dynamometer, with 3 maximal contractions of the left and right hands. All measures were conducted by staff with training in clinical exercise testing. Among 295 breast cancer survivors, 1-RM bench press strength was 18.2±6.1kg (range, 2.2-43.0kg), and isometric handgrip strength was 23.5±5.8kg (range, 9.0-43.0kg). The strongest correlate of 1-RM bench press strength was the average isometric handgrip strength of both hands (r=.399; Pisometric handgrip strength of both hands overestimated 1-RM bench press strength by 4.7kg (95% limits of agreement, -8.2 to 17.6kg). In a multivariable linear regression model, the average isometric handgrip strength of both hands (β=.31; Pstrength (R 2 =.23). Isometric handgrip strength is a poor surrogate for 1-RM bench press strength among breast cancer survivors. 1-RM bench press strength and isometric handgrip strength quantify distinct components of muscular strength. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  1. A high frequency test bench for rapid single-flux-quantum circuits

    International Nuclear Information System (INIS)

    Engseth, H; Intiso, S; Rafique, M R; Tolkacheva, E; Kidiyarova-Shevchenko, A

    2006-01-01

    We have designed and experimentally verified a test bench for high frequency testing of rapid single-flux-quantum (RSFQ) circuits. This test bench uses an external tunable clock signal that is stable in amplitude, phase and frequency. The high frequency external clock reads out the clock pattern stored in a long shift register. The clock pattern is consequently shifted out at high speed and split to feed both the circuit under test and an additional shift register in the test bench for later verification at low speed. This method can be employed for reliable high speed verification of RSFQ circuit operation, with use of only low speed read-out electronics. The test bench consists of 158 Josephson junctions and the occupied area is 3300 x 660 μm 2 . It was experimentally verified up to 33 GHz with ± 21.7% margins on the global bias supply current

  2. Bench scale demonstration and conceptual engineering for DETOXSM catalyzed wet oxidation

    International Nuclear Information System (INIS)

    Moslander, J.; Bell, R.; Robertson, D.; Dhooge, P.; Goldblatt, S.

    1994-01-01

    Laboratory and bench scale studies of the DETOX SM catalyzed wet oxidation process have been performed with the object of developing the process for treatment of hazardous and mixed wastes. Reaction orders, apparent rates, and activation energies have been determined for a range of organic waste surrogates. Reaction intermediates and products have been analyzed. Metals' fates have been determined. Bench scale units have been designed, fabricated, and tested with solid and liquid organic waste surrogates. Results from the laboratory and bench scale studies have been used to develop conceptual designs for application of the process to hazardous and mixed wastes

  3. Low-load bench press and push-up induce similar muscle hypertrophy and strength gain.

    Science.gov (United States)

    Kikuchi, Naoki; Nakazato, Koichi

    2017-06-01

    To investigate the effect of push-up training with a similar load of to 40% of 1- repetition maximumal (1RM) bench press on muscle hypertrophy and strength gain in men. Eighteen male participants (age, 20.2 ± 0.73 years, range: 19-22 years, height: 169.8 ± 4.4 cm, weight: 64.5 ± 4.7 kg) were randomly assigned to one of two experimental groups: bench press at 40%1RM (bench-press group, n = 9) or push-ups with position adjusted (e.g. kneeling) to the same load of bench-press 40%1RM (push-up group, n = 9), performed twice per week for 8 weeks. Muscle thickness at three sites (biceps, triceps, and pectoralis major), bench-press 1RM, maximum repetition at 40%1RM, and power output (medicine ball throw) were measured before and after the training period. Significant increases in 1RM and muscle thickness (triceps and pectoralis major) were observed in bench-press group (1RM, from 60.0 ± 12.1 kg to 65.0 ± 12.1 kg, p bench-press group (28.4 ± 3.3 mm to 31.5 ± 3.7 mm, p bench press is comparably effective for muscle hypertrophy and strength gain over an 8-week training period.

  4. The Association between Maximal Bench Press Strength and Isometric Handgrip Strength among Breast Cancer Survivors

    Science.gov (United States)

    Rogers, Benjamin H.; Brown, Justin C.; Gater, David R.; Schmitz, Kathryn H.

    2016-01-01

    Objective One-repetition maximum (1-RM) bench press strength is considered the gold standard to quantify upper-body muscular strength. Isometric handgrip strength is frequently used as a surrogate for 1-RM bench press strength among breast cancer (BrCa) survivors. The relationship between 1-RM bench press strength and isometric handgrip strength, however, has not been characterized among BrCa survivors. Design Cross-sectional study. Setting Laboratory. Participants Community-dwelling BrCa survivors. Interventions Not applicable. Main Outcome Measure 1-RM bench press strength was measured with a barbell and exercise bench. Isometric handgrip strength was measured using an isometric dynamometer with three maximal contractions of left and right hands. All measures were conducted by staff with training in clinical exercise testing. Results Among 295 BrCa survivors, 1-RM bench press strength was 18.2±6.1 kg (range: 2.2-43.0) and isometric handgrip strength was 23.5±5.8 kg (range: 9.0-43.0). The strongest correlate of 1-RM bench press strength was the average isometric handgrip strength of both hands (r=0.399; Pisometric handgrip strength of both hands overestimated 1-RM bench press strength by 4.7 kg (95% limits of agreement: −8.2 to 17.6). In a multivariable linear regression model, the average isometric handgrip strength of both hands (β=0.31; Pstrength (R2=0.23). Conclusions Isometric handgrip strength is a poor surrogate for 1-RM bench press strength among BrCa survivors. 1-RM bench press and isometric handgrip strength quantify distinct components of muscular strength. PMID:27543047

  5. Recreation Sports to host Sixth Annual Bench Press Competition March 17

    OpenAIRE

    Kropff, Catherine L.

    2007-01-01

    Music will blare, red and white lights will flash, and fans will cheer at the Sixth Annual Bench Press Competition to be held Saturday, March 17 at Virginia Tech. Participants will go to the bench to show their lifting skills beginning at 10 a.m. in War Memorial Gym.

  6. A comparison of muscle activity in concentric and counter movement maximum bench press.

    Science.gov (United States)

    van den Tillaar, Roland; Ettema, Gertjan

    2013-01-01

    The purpose of this study was to compare the kinematics and muscle activation patterns of regular free-weight bench press (counter movement) with pure concentric lifts in the ascending phase of a successful one repetition maximum (1-RM) attempt in the bench press. Our aim was to evaluate if diminishing potentiation could be the cause of the sticking region. Since diminishing potentiation cannot occur in pure concentric lifts, the occurrence of a sticking region in this type of muscle actions would support the hypothesis that the sticking region is due to a poor mechanical position. Eleven male participants (age 21.9 ± 1.7 yrs, body mass 80.7 ± 10.9 kg, body height 1.79 ± 0.07 m) conducted 1-RM lifts in counter movement and in pure concentric bench presses in which kinematics and EMG activity were measured. In both conditions, a sticking region occurred. However, the start of the sticking region was different between the two bench presses. In addition, in four of six muscles, the muscle activity was higher in the counter movement bench press compared to the concentric one. Considering the findings of the muscle activity of six muscles during the maximal lifts it was concluded that the diminishing effect of force potentiation, which occurs in the counter movement bench press, in combination with a delayed muscle activation unlikely explains the existence of the sticking region in a 1-RM bench press. Most likely, the sticking region is the result of a poor mechanical force position.

  7. [A man with a painful upper arm after bench press exercise].

    Science.gov (United States)

    Sijtsma, Ben C T; van der Veen, Hugo C; van Raay, Jos J A M

    2015-01-01

    A 22-year-old male bodybuilder presented with pain and a haematoma of his right upper arm after bench press exercises. Suspicion of a pectoralis muscle tear was confirmed by MRI and surgical repair was performed. Ruptures of the pectoralis major muscle are rare, but may occur in young male bodybuilders, typically after bench press exercises.

  8. Comparative tests of bench equipment for fuel control system testing of gas-turbine engine

    Science.gov (United States)

    Shendaleva, E. V.

    2018-04-01

    The relevance of interlaboratory comparative researches is confirmed by attention of world metrological community to this field of activity. Use of the interlaboratory comparative research methodology not only for single gages collation, but also for bench equipment complexes, such as modeling stands for fuel control system testing of gas-turbine engine, is offered. In this case a comparative measure of different bench equipment will be the control fuel pump. Ensuring traceability of measuring result received at test benches of various air enterprises, development and introduction of national standards to practice of bench tests and, eventually, improvement of quality and safety of a aircraft equipment is result of this approach.

  9. Effect of Fatigue Upon Performance and Electromyographic Activity in 6-RM Bench Press.

    Science.gov (United States)

    van den Tillaar, Roland; Saeterbakken, Atle

    2014-03-27

    The aim of this study was to examine the effect of fatigue during one set of 6-RM bench pressing upon the muscle patterning and performance. Fourteen resistance-trained males (age 22.5±2.0 years, stature 1.82±0.07 m, body mass 82.0±7.8 kg) conducted a 6-RM bench press protocol. Barbell kinematics and EMG activity of pectoralis major, deltoid anterior, biceps brachii, triceps brachii, rectus abdominis, oblique external and erector spinae were measured in each repetition during the 6-RM bench press. Total lifting time increased and the velocity in the ascending movement decreased (p≤0.001). However, the kinematics in the descending phase deferred: the time decreased and velocity increased during the 6-RM (p≤0.001). Generally, muscles increased their EMG amplitude during the six repetitions in the ascending movement, while only three of the seven measured muscles showed an increase over the six repetitions in the descending part in 6-RM bench pressing. It was concluded that the bench pressing performance decreased (lower barbell velocities and longer lifting times) with increasing fatigue in the 6-RM execution. Furthermore EMG increased in the prime movers and the trunk stabilizers (abdominal and spine), while the antagonist muscle (biceps) activity was not affected by fatigue during the lifting phase in a single set of 6-RM bench pressing.

  10. Bench press exercise: the key points.

    Science.gov (United States)

    Padulo, J; Laffaye, G; Chaouachi, A; Chamari, K

    2015-06-01

    The bench press exercise (BPE) is receiving increasing interest as a field testing, training/therapeutic modality to improve neuromuscular performance or to increase bone mass density. Several studies have been performed using BPE as a standard for increasing upper-limb strength. For this purpose, the position of the bar, the loads, the sets, the number of repetitions, the recovery time in-between sets, the movement speed, the muscular work and the use of the determination of the one repetition maximum (1-RM) are the classical tools investigated in the literature that have been shown to affect the BPE effect on neuromuscular. The goal of the present short review is to make a picture of the current knowledge on the bench press exercise, which could be very helpful for a better understanding of this standard movement and its effects. Based on the related literature, several recommendations on these key points are presented here.

  11. Velocity- and power-load relationships of the bench pull vs. bench press exercises.

    Science.gov (United States)

    Sánchez-Medina, L; González-Badillo, J J; Pérez, C E; Pallarés, J G

    2014-03-01

    This study compared the velocity- and power-load relationships of the antagonistic upper-body exercises of prone bench pull (PBP) and bench press (BP). 75 resistance-trained athletes performed a progressive loading test in each exercise up to the one-repetition maximum (1RM) in random order. Velocity and power output across the 30-100% 1RM were significantly higher for PBP, whereas 1RM strength was greater for BP. A very close relationship was observed between relative load and mean propulsive velocity for both BP (R2=0.97) and PBP (R2=0.94) which enables us to estimate %1RM from velocity using the obtained prediction equations. Important differences in the load that maximizes power output (Pmax) and the power profiles of both exercises were found according to the outcome variable used: mean (MP), peak (PP) or mean propulsive power (MPP). When MP was considered, the Pmax load was higher (56% BP, 70% PBP) than when PP (37% BP, 41% PBP) or MPP (37% BP, 46% PBP) were used. For each variable there was a broad range of loads at which power output was not significantly different. The differing velocity- and power-load relationships between PBP and BP seem attributable to the distinct muscle architecture and moment arm levers involved in these exercises. © Georg Thieme Verlag KG Stuttgart · New York.

  12. Comparison of concentric and eccentric bench press repetitions to failure.

    Science.gov (United States)

    Kelly, Stephen B; Brown, Lee E; Hooker, Steven P; Swan, Pamela D; Buman, Matthew P; Alvar, Brent A; Black, Laurie E

    2015-04-01

    Eccentric muscle actions (ECC) are characterized by muscle lengthening, despite actin-myosin crossbridge formation. Muscles acting eccentrically are capable of producing higher levels of force compared with muscles acting concentrically. The purpose of this study was to determine whether ECC bench press yields greater strength than concentric (CON) as determined by 1 repetition maximum (1RM). Additionally, a comparison was made examining differences in the number of repetitions to failure at different relative intensities of 1RM. Thirty healthy men (age = 24.63 ± 5.6 years) were tested for 1RM in CON and ECC bench press and the number of repetitions completed at 60, 70, 80, and 90% 1RM. For CON repetitions, the weight was mechanically lowered to the chest, and the participant pressed it up until the elbows were fully extended. The ECC bench press consisted of lowering a barbell from a fully extended elbow position to the chest in a continuous controlled manner for 3 seconds as determined by electronic metronome. Paired t-tests showed that ECC 1RM (115.99 ± 31.08 kg) was significantly (p ≤ 0.05) greater than CON 1RM (93.56 ± 26.56 kg), and the number of repetitions completed at 90% 1RM was significantly (p ≤ 0.05) greater in ECC (7.67 ± 3.24) as compared with CON (4.57 ± 2.21). There were no significant differences in number of completed repetitions during CON and ECC bench press at 60, 70, and 80% 1RM. These data indicate that ECC actions yield increased force capabilities (∼120%) as compared with CON in the bench press and may be less prone to fatigue, especially at higher intensities. These differences suggest a need to develop unique strategies for training eccentrically.

  13. Location of Instability During a Bench Press Alters Movement Patterns and Electromyographical Activity.

    Science.gov (United States)

    Nairn, Brian C; Sutherland, Chad A; Drake, Janessa D M

    2015-11-01

    Instability training devices with the bench press exercise are becoming increasingly popular. Typically, the instability device is placed at the trunk/upper body (e.g., lying on a Swiss ball); however, a recent product called the Attitube has been developed, which places the location of instability at the hands by users lifting a water-filled tube. Therefore, the purpose of this study was to analyze the effects of different instability devices (location of instability) on kinematic and electromyographical patterns during the bench press exercise. Ten healthy males were recruited and performed 1 set of 3 repetitions for 3 different bench press conditions: Olympic bar on a stable bench (BENCH), Olympic bar on a stability ball (BALL), and Attitube on a stable bench (TUBE). The eccentric and concentric phases were analyzed in 10% intervals while electromyography was recorded from 24 electrode sites, and motion capture was used to track elbow flexion angle and 3-dimensional movement trajectories and vertical velocity of the Bar/Attitube. The prime movers tended to show a reduction in muscle activity during the TUBE trials; however, pectoralis major initially showed increased activation during the eccentric phase of the TUBE condition. The trunk muscle activations were greatest during the TUBE and smallest during the BAR. In addition, the TUBE showed decreased range of elbow flexion and increased medial-lateral movement of the Attitube itself. The results further support the notion that instability devices may be more beneficial for trunk muscles rather than prime movers.

  14. A Coupling Vibration Test Bench and the Simulation Research of a Maglev Vehicle

    Directory of Open Access Journals (Sweden)

    Weihua Ma

    2015-01-01

    Full Text Available To study the characteristics of the coupling vibration between a maglev vehicle and its track beam system and to improve the performance of the levitation system, a new type of vibration test bench was developed. Take a single maglev frame as the study object; simulation of the coupling vibration of the maglev vehicle, levitation system, and track beam were achieved. In addition, all types of real track irregularity excitations can be simulated using hydraulic actuators of the test bench. To expand the research scope, a simulation model was developed that can conduct the simulation research synergistically with the test bench. Based on a dynamics model of the test bench, the dynamics simulation method determined the influence on the levitation control performance of three factors: the track beam support stiffness, the track beam mass, and the track irregularity. The vibration resonance phenomenon of the vehicle/track system was reproduced by the dynamics simulation, and a portion of the simulation results were validated by the test results. By combining the test bench and the dynamics model, experiments can be guided by the simulation results, and the experimental results can validate the dynamics simulation results.

  15. Characterization benches for neutrino telescope Optical Modules at the APC laboratory

    Science.gov (United States)

    Avgitas, Theodore; Creusot, Alexandre; Kouchner, Antoine

    2016-04-01

    As has been demonstrated by the first generation of neutrino telescopes Antares and IceCube, precise knowledge of the photon detection efficiency of optical modules is of fundamental importance for the understanding of the instrument and accurate event reconstruction. Dedicated test benches have been developed to measure all related quantities for the Digital Optical Modules of the KM3NeT neutrino telescope being currently deployed in the Mediterranean sea. The first bench is a black box with robotic arms equipped with a calibrated single photon source or laser which enable a precise mapping of the detection efficiency at arbitrary incident angles as well as precise measurements of the time delays induced by the photodetection chain. These measurement can be incorporated and compared to full GEANT MonteCarlo simulations of the optical modules. The second bench is a 2 m×2 m ×2 m water tank equipped with muon hodoscopes on top and bottom. It enables to study and measure the angular dependence of the DOM's detection efficiency of the Cherenkov light produced in water by relativistic muons, thus reproducing in situ detection conditions. We describe these two benches and present their first results and status.

  16. Bench press training program with attached chains for female volleyball and basketball athletes.

    Science.gov (United States)

    Burnham, Timothy R; Ruud, Jason D; McGowan, Robert

    2010-02-01

    Attaching chains to barbells to increase strength and power has become popular for athletes; however, little scientific evidence supports this practice. The present purpose was to compare chain training to traditional training for the bench press. Women collegiate athletes in volleyball and basketball (N = 19) participated in a 16-session bench press program. They were matched into either a Traditional or a Chain training group by 1-repetition maximum (1RM). The Traditional group performed the bench press with conventional equipment, while the Chain group trained with attached chains (5% of weight). Analysis showed a significant increase in 1RM for both groups over 16 sessions, Traditional +11.8% and Chain +17.4%. The difference between the groups was not statistically significant, but suggests the women who trained with attached chains improved their bench press more than the Traditional group.

  17. On line isotopic separator test benches at GANIL

    International Nuclear Information System (INIS)

    Anne, R.; Bru, B.; Joubert, A.; Leroy, R.; Obert, J.; Putaux, J.C.; Liang, C.F.; Paris, P.; Orr, N.; Steckmeyer, J.C.

    1993-01-01

    A first version of isotopic separator on line test bench has been built in order to test the feasibility of the production of radioactive species from 96 MeV/u of 20 Ne impinging a thick target of MgO. This test bench was equipped with a very compact ECR ion source (Nanogan) entirely made from permanent magnets and operating at 10 Ghz. 18 Ne 2,4+ ; 19N e 1,2,3,4+ and 23,24 Ne 1+ has been produced and ionized. A new more performing separator (SIRa) allowing the use of different types of ion sources will be completed by the end of 1993. (author) 4 refs., 4 figs., 1 tab

  18. Effect of Fatigue Upon Performance and Electromyographic Activity in 6-RM Bench Press

    OpenAIRE

    van den Tillaar, Roland; Saeterbakken, Atle

    2014-01-01

    The aim of this study was to examine the effect of fatigue during one set of 6-RM bench pressing upon the muscle patterning and performance. Fourteen resistance-trained males (age 22.5±2.0 years, stature 1.82±0.07 m, body mass 82.0±7.8 kg) conducted a 6-RM bench press protocol. Barbell kinematics and EMG activity of pectoralis major, deltoid anterior, biceps brachii, triceps brachii, rectus abdominis, oblique external and erector spinae were measured in each repetition during the 6-RM bench p...

  19. Test-bench for characterization of steady state magnetic sensors parameters in wide temperature range

    International Nuclear Information System (INIS)

    Kovařík, Karel; Ďuran, Ivan; Sentkerestiová, Jana; Šesták, David

    2013-01-01

    Highlights: •Prepared test bench for calibration of steady state magnetic sensors. •Test-bench design optimized for calibration up to 300 °C. •Test-bench is remotely controllable and allows long term measurements. •Construction allows easy manipulation with even irradiated samples. -- Abstract: Magnetic sensors in ITER tokamak and in other future fusion devices will face an environment with temperature often elevated well above 200 °C. Dedicated test benches are needed to allow characterization of performance of magnetic sensors at such elevated temperatures. This contribution describes realization of test bench for calibration of steady state magnetic sensors based on Hall effect. The core of the set-up is the coil providing DC calibration magnetic field. Optimization of coils design to ensure its compatibility with elevated temperature up to 300 °C is described. Optimized coil was manufactured, and calibrated both at room temperature and at temperature of 250 °C. Measured calibration magnetic field of the coil biased by a 30 A commercial laboratory power supplies is 224 mT. The coil is supplemented by PID regulated air cooling system for fine control of sensors temperature during measurements. Data acquisition system is composed from PC A/D converter boards with resolution below 1 μV. The key parameters of the test bench are remotely controllable and the system allows long term continuous measurements including tests of irradiated samples. The performance of the test bench is demonstrated on recent measurements with metal Hall sensors based on thin copper sensing layers

  20. A virtual model of the bench press exercise.

    Science.gov (United States)

    Rahmani, Abderrahmane; Rambaud, Olivier; Bourdin, Muriel; Mariot, Jean-Pierre

    2009-08-07

    The objective of this study was to design and validate a three degrees of freedom model in the sagittal plane for the bench press exercise. The mechanical model was based on rigid segments connected by revolute and prismatic pairs, which enabled a kinematic approach and global force estimation. The method requires only three simple measurements: (i) horizontal position of the hand (x(0)); (ii) vertical displacement of the barbell (Z) and (iii) elbow angle (theta). Eight adult male throwers performed maximal concentric bench press exercises against different masses. The kinematic results showed that the vertical displacement of each segment and the global centre of mass followed the vertical displacement of the lifted mass. Consequently, the vertical velocity and acceleration of the combined centre of mass and the lifted mass were identical. Finally, for each lifted mass, there were no practical differences between forces calculated from the bench press model and those simultaneously measured with a force platform. The error was lower than 2.5%. The validity of the mechanical method was also highlighted by a standard error of the estimate (SEE) ranging from 2.0 to 6.6N in absolute terms, a coefficient of variation (CV) or =0.99 for all the lifts (pbench press exercises in both field and laboratory conditions.

  1. Spontaneous pneumomediastinum after bench press training.

    Science.gov (United States)

    Nishino, Tomoya

    2017-04-01

    Spontaneous pneumomediastinum is often associated with asthma and mainly affects adolescent males with a tall, thin body habitus. A 17-year-old man complained of chest and pharyngeal pain after bench press training and spontaneous pneumomediastinum was diagnosed. It should be considered in the differential diagnosis of chest pain of uncertain cause.

  2. Effect of Barbell Weight on the Structure of the Flat Bench Press.

    Science.gov (United States)

    Król, Henryk; Gołaś, Artur

    2017-05-01

    Król, H and Gołaś, A. Effect of barbell weight on the structure of the flat bench press. J Strength Cond Res 31(5): 1321-1337, 2017-In this study, we have used the multimodular measuring system SMART. The system consisted of 6 infrared cameras and a wireless module to measure muscle bioelectric activity. In addition, the path of the barbell was measured with a special device called the pantograph. Our study concerns the change in the structure of the flat bench press when the weight of the barbell is increased. The research on the bench press technique included both the causes of the motion: the internal structure of the movement and the external kinematic structure showing the effects of the motion, i.e., all the characteristics of the movement. Twenty healthy, male recreational weight trainers with at least 1 year of lifting experience (the mean ± SD = 3.3 ± 1.6 years) were recruited for this study. The subjects had a mean body mass of 80.2 ± 8.6 kg, an average height of 1.77 ± 0.08 m, and their average age was 24.7 ± 0.9 years. In the measuring session, the participants performed consecutive sets of a single repetition of bench pressing with an increasing load (about 70, 80, 90, and 100% of their 1 repetition maximum [1RM]). The results showed a significant change in the phase structure of the bench press, as the barbell weight was increased. While doing the bench press at a 100% 1RM load, the pectoralis major changes from being the prime mover to being the supportive prime mover. At the same time, the role of the prime mover is taken on by the deltoideus anterior. The triceps brachii, in particular, clearly shows a greater involvement.

  3. Anthropometry as a predictor of bench press performance done at different loads.

    Science.gov (United States)

    Caruso, John F; Taylor, Skyler T; Lutz, Brant M; Olson, Nathan M; Mason, Melissa L; Borgsmiller, Jake A; Riner, Rebekah D

    2012-09-01

    The purpose of our study was to examine the ability of anthropometric variables (body mass, total arm length, biacromial width) to predict bench press performance at both maximal and submaximal loads. Our methods required 36 men to visit our laboratory and submit to anthropometric measurements, followed by lifting as much weight as possible in good form one time (1 repetition maximum, 1RM) in the exercise. They made 3 more visits in which they performed 4 sets of bench presses to volitional failure at 1 of 3 (40, 55, or 75% 1RM) submaximal loads. An accelerometer (Myotest Inc., Royal Oak MI) measured peak force, velocity, and power after each submaximal load set. With stepwise multivariate regression, our 3 anthropometric variables attempted to explain significant amounts of variance for 13 bench press performance indices. For criterion measures that reached significance, separate Pearson product moment correlation coefficients further assessed if the strength of association each anthropometric variable had with the criterion was also significant. Our analyses showed that anthropometry explained significant amounts (p bench press prowess in athletes.

  4. Contextual interference effects on the acquisition of skill and strength of the bench press.

    Science.gov (United States)

    Naimo, Marshall A; Zourdos, Michael C; Wilson, Jacob M; Kim, Jeong-Su; Ward, Emery G; Eccles, David W; Panton, Lynn B

    2013-06-01

    The purpose of this study was to investigate contextual interference effects on skill acquisition and strength gains during the learning of the bench press movement. Twenty-four healthy, college-aged males and females were stratified to control, high contextual interference (HCI), and low contextual interference (LCI) groups. Treatment groups were provided with written and visual instruction on proper bench press form and practiced the bench press and dart throwing for four weeks. Within each session, LCI performed all bench press sets before undertaking dart-throws. HCI undertook dart-throws immediately following each set of bench press. Control only did testing. Measurements, including one repetition maximum (1RM), checklist scores based on video recordings of participants' 1RM's, and dart-throw test scores were taken at pre-test, 1 week, 2 week, post-test, and retention test. Results were consistent with the basic premise of the contextual interference effect. LCI had significant improvements in percent 1RM and checklist scores during training, but were mostly absent after training (post-test and retention test). HCI had significant improvements in percent 1RM and checklist scores both during and after training. Thus, HCI may augment strength and movement skill on the bench press since proper technique is an important component of resistance exercise movements. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Encounters on a Shape-changing Bench

    DEFF Research Database (Denmark)

    Kinch, Sofie; Grönvall, Erik; Petersen, Marianne Graves

    2014-01-01

    ; a concert hall, an airport and a shopping mall. We gathered insights from more than 120 people, as they unexpectedly encountered the shape changing capabilities of the bench. By taking the user tests out of the lab and into the wild, we explored the influence of context on the users experience of a shape...

  6. Mathematical Lens: How Much Can You Bench?

    Science.gov (United States)

    Bolognese, Chris A.

    2013-01-01

    "How Much Can You Bench?" appears in the "Mathematical Lens" section of "Mathematics Teacher." "Mathematical Lens" uses photographs as a springboard for mathematical inquiry and appears in every issue of "Mathematics Teacher." This month the mathematics behind the photograph includes finding areas…

  7. A comparison of successful and unsuccessful attempts in maximal bench pressing.

    Science.gov (United States)

    van den Tillaar, Roland; Ettema, Gertjan

    2009-11-01

    This study was designed to compare the differences in EMG and kinematics between successful and unsuccessful attempts in bench pressing at one repetition maximum (1RM) in recreational weight-trained subjects. We hypothesized that failure occurs during the sticking period (the period during which there is a temporary reduction in movement velocity). Eleven male subjects (age = 21.9 +/- 1.8 yr, mass = 80.0 +/- 11.2 kg, height = 1.79 +/- 0.08 m) with at least 1 yr of bench press training experience participated in this study. They performed attempts at 1RM and 1RM + 2.5 kg in bench press during which kinematics and muscle activity were recorded. One successful attempt and one unsuccessful attempt were used for further analysis. Both attempts showed the same sticking period, but only half of the failures occurred during that period. The main differences in the kinematics occurred during the sticking period. Muscle activity, in contrast, showed the same pattern in both attempts and only differed during the downward and the start of the upward movement of the lift. The sticking period occurs in both successful and unsuccessful attempts in maximal bench press. However, failure does not always occur during the sticking period.

  8. Importance of upper-limb inertia in calculating concentric bench press force.

    Science.gov (United States)

    Rambaud, Olivier; Rahmani, Abderrahmane; Moyen, Bernard; Bourdin, Muriel

    2008-03-01

    The purpose of this study was to investigate the influence of upper-limb inertia on the force-velocity relationship and maximal power during concentric bench press exercise. Reference peak force values (Fpeakp) measured with a force plate positioned below the bench were compared to those measured simultaneously with a kinematic device fixed on the barbell by taking (Fpeakt) or not taking (Fpeakb) upper-limb inertia into account. Thirteen men (27.8 +/- 4.1 years, 184.6 +/- 5.5 cm, 99.5 +/- 18.6 kg) performed all-out concentric bench press exercise against 8 loads ranging between 7 and 74 kg. The results showed that for each load, Fpeakb was significantly less than Fpeakp (P force (F0), maximal velocity (V0), optimal velocity (Vopt), and maximal power (Pmax), extrapolated from the force- and power-velocity relationships determined with the kinematic device, were significantly underestimated when upper-limb inertia was ignored. The results underline the importance of taking account of the total inertia of the moving system to ensure precise evaluation of upper-limb muscular characteristics in all-out concentric bench press exercise with a kinematic device. A major application of this study would be to develop precise upper-limb muscular characteristic evaluation in laboratory and field conditions by using a simple and cheap kinematic device.

  9. Acute chest pain after bench press exercise in a healthy young adult.

    Science.gov (United States)

    Smereck, Janet A; Papafilippaki, Argyro; Sudarshan, Sawali

    2016-01-01

    Bench press exercise, which involves repetitive lifting of weights to full arm extension while lying supine on a narrow bench, has been associated with complications ranging in acuity from simple pectoral muscle strain, to aortic and coronary artery dissection. A 39-year-old man, physically fit and previously asymptomatic, presented with acute chest pain following bench press exercise. Diagnostic evaluation led to the discovery of critical multivessel coronary occlusive disease, and subsequently, highly elevated levels of lipoprotein (a). Judicious use of ancillary testing may identify the presence of "high-risk" conditions in a seemingly "low-risk" patient. Emergency department evaluation of the young adult with acute chest pain must take into consideration an extended spectrum of potential etiologies, so as to best guide appropriate management.

  10. Study and designing of the ''caliprax'' measurement bench

    International Nuclear Information System (INIS)

    Barriere, J.Ch.

    2001-09-01

    Probing the matter in order to check its elementary constituents, that is the goal of the particle physic. In this field, the experiments consist in colliding highly energetic particle beams and observing the new born particles. These observations are based on big particle detectors whose running is dependant on the precise knowledge of their geometry (position of the detection chambers). To achieve this, the detectors are equipped with alignment sensors, which have to be calibrated before. This document describes the study and the making of a calibration bench for the 'Praxial' (PRoximity AXIAL) type sensors, and other works related to these sensors. In a first part, we determine and apply a method to set the tools used to fix the sensor stands on the detection chambers. These settings are made with the use of a tridimensional measuring machine. Then, we study the stands themselves. These investigations concern mechanics: positioning quality of the sensors in their stands, bending of the supports due to the tightening. In this part too, the studies are in the field of dimensional metrology. After this, the works are reoriented toward the bench, with the choice of the displacement sensors among two different technologies: optical, with the Rasnik system, and mechanical, with linear probes as LVDT (Linear Variable Differential Transformer). Following the discovery of an ambiguity on the Rasnik system, we go on the tests to understand its behaviour. We introduce the theory of the alignment sensors calibration, which is based on a minimization calculation. The computer programs are explained in a chapter, and in an other, the implementation of the quality assurance procedures. An other part describes the mechanical studies and the problems they cause. Because of a delay onset of the project, we make a model of the bench. This dummy allows us to test every single function of the final bench. With this device, we record manually the first calibration data and use them

  11. Additive Manufactured Coronagraph Bench for Detection of Exoplanets

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to use additive manufacturing (AM) to build a Coronagraph Bench engineering test unit.  The versatility inherent in the 3D-printing process allows for a...

  12. NetBench. Automated Network Performance Testing

    CERN Document Server

    Cadeddu, Mattia

    2016-01-01

    In order to evaluate the operation of high performance routers, CERN has developed the NetBench software to run benchmarking tests by injecting various traffic patterns and observing the network devices behaviour in real-time. The tool features a modular design with a Python based console used to inject traffic and collect the results in a database, and a web user

  13. TACLeBench: A benchmark collection to support worst-case execution time research

    DEFF Research Database (Denmark)

    Falk, Heiko; Altmeyer, Sebastian; Hellinckx, Peter

    2016-01-01

    -source programs, adapted them to a common coding style, and provide the collection in open-source. The benchmark collection is called TACLeBench and is available from GitHub in version 1.9 at the publication date of this paper. One of the main features of TACLeBench is that all programs are self-contained without...... any dependencies on standard libraries or an operating system....

  14. Bench Press Upper-Body Muscle Activation Between Stable and Unstable Loads.

    Science.gov (United States)

    Dunnick, Dustin D; Brown, Lee E; Coburn, Jared W; Lynn, Scott K; Barillas, Saldiam R

    2015-12-01

    The bench press is one of the most commonly used upper-body exercises in training and is performed with many different variations, including unstable loads (ULs). Although there is much research on use of an unstable surface, there is little to none on the use of an UL. The purpose of this study was to investigate muscle activation during the bench press while using a stable load (SL) vs. UL. Twenty resistance-trained men (age = 24.1 ± 2 years; ht = 177.5 ± 5.8 cm; mass = 88.7 ± 13.7 kg) completed 2 experimental conditions (SL and UL) at 2 different intensities (60 and 80% one repetition maximum). Unstable load was achieved by hanging 16 kg kettlebells by elastic bands from the end of the bar. All trial lifts were set to a 2-second cadence with a slight pause at the bottom. Subjects had electrodes attached to 5 muscles (pectoralis major, anterior deltoid, medial deltoid, triceps brachii, and latissimus dorsi) and performed 3 isometric bench press trials to normalize electromyographic data. All 5 muscles demonstrated significantly greater activation at 80% compared with 60% load and during concentric compared with eccentric actions. These results suggest that upper body muscle activation is not different in the bench press between UL and SL. Therefore, coaches should use their preference when designing training programs.

  15. Development of Fuzzy Logic Controller for Quanser Bench-Top Helicopter

    Science.gov (United States)

    Jafri, M. H.; Mansor, H.; Gunawan, T. S.

    2017-11-01

    Bench-top helicopter is a laboratory scale helicopter that usually used as a testing bench of the real helicopter behavior. This helicopter is a 3 Degree of Freedom (DOF) helicopter which works by three different axes wshich are elevation, pitch and travel. Thus, fuzzy logic controller has been proposed to be implemented into Quanser bench-top helicopter because of its ability to work with non-linear system. The objective for this project is to design and apply fuzzy logic controller for Quanser bench-top helicopter. Other than that, fuzzy logic controller performance system has been simulated to analyze and verify its behavior over existing PID controller by using Matlab & Simulink software. In this research, fuzzy logic controller has been designed to control the elevation angle. After simulation has been performed, it can be seen that simulation result shows that fuzzy logic elevation control is working for 4°, 5° and 6°. These three angles produce zero steady state error and has a fast response. Other than that, performance comparisons have been performed between fuzzy logic controller and PID controller. Fuzzy logic elevation control has a better performance compared to PID controller where lower percentage overshoot and faster settling time have been achieved in 4°, 5° and 6° step response test. Both controller are have zero steady state error but fuzzy logic controller is managed to produce a better performance in term of settling time and percentage overshoot which make the proposed controller is reliable compared to the existing PID controller.

  16. Efficiency of contour benches, filling-in and silting-up of a hillside reservoir in a semi-arid climate in Tunisia

    Science.gov (United States)

    Baccari, Noamen; Boussema, Mohamed Rached; Lamachère, Jean-Marie; Nasri, Slah

    2008-01-01

    The El Gouazine catchment area (18.1 km 2), located in semi-arid central Tunisia (average annual rainfall 350 mm), was equipped with total retention contour benches on 43% of its surface area between June 1996 and July 1997. In order to analyze the efficiency of these benches on the catchment area, different thematic maps (slope, lithology, land use, hydrographic network) were crossed using GIS with a map that located the benches and their breaks. Specific topographical surveys were also carried out on a series of 14 benches' in order to characterize the development of their holding capacities. To evaluate the impact of the contour bench installation on the catchment area, the change of liquid and solid inflow was measured at the catchment area outlet two years before and eight years after the bench installation. On-site surveys showed that contour bench dysfunction in the El Gouazine catchment area could not have been caused by man. However, three main physical causes could explain the dysfunction: placement of benches on gypsum clay soils, location of breaks on the hydrographic network, and slope greater than 25%. Topographic surveys showed that the benches initial holding capacity varied between 1 and 3 m 3 per linear metre for a construction standard fixed at 2.28 m 3. These surveys also showed that, nine years after their construction, the benches had lost 10 to 50% of their initial holding capacity. After installing benches in the El Gouazine catchment area, solid inflow was only reduced by 30%, whereas liquid inflow was reduced seven to eight times during a four-year period, which greatly limited the possibility of downstream irrigation. Annual runoff coefficients, at 4.5% before bench installation, were again at 5.1% in 2002-2003, and the silting-up rate was evaluated, in June 2005, as identical to its value before installation. Bench breakage and silting up of upstream canals explain these changes. The results of this study should serve to improve contour

  17. Neuromuscular activity during bench press exercise performed with and without the preexhaustion method.

    Science.gov (United States)

    Brennecke, Allan; Guimarães, Thiago M; Leone, Ricardo; Cadarci, Mauro; Mochizuki, Luiz; Simão, Roberto; Amadio, Alberto Carlos; Serrão, Júlio C

    2009-10-01

    The purpose of the present study was to investigate the effects of exercise order on the tonic and phasic characteristics of upper-body muscle activity during bench press exercise in trained subjects. The preexhaustion method involves working a muscle or a muscle group combining a single-joint exercise immediately followed by a multi-joint exercise (e.g., flying exercise followed by bench press exercise). Twelve subjects performed 1 set of bench press exercises with and without the preexhaustion method following 2 protocols (P1-flying before bench press; P2-bench press). Both exercises were performed at a load of 10 repetition maximum (10RM). Electromyography (EMG) sampled at 1 kHz was recorded from the pectoralis major (PM), anterior deltoid (DA), and triceps brachii (TB). Kinematic data (60 Hz) were synchronized to define upward and downward phases of exercise. No significant (p > 0.05) changes were seen in tonic control of PM and DA muscles between P1 and P2. However, TB tonic aspect of neurophysiologic behavior of motor units was significantly higher (p 0.05). The kinematic pattern of movement changed as a result of muscular weakness in P1. Angular velocity of the right shoulder performed during the upward phase of the bench press exercise was significantly slower (p < 0.05) during P1. Our results suggest that the strategies set by the central nervous system to provide the performance required by the exercise are held constant throughout the exercise, but the tonic aspects of the central drive are increased so as to adapt to the progressive occurrence of the neuromuscular fatigue. Changes in tonic control as a result of the muscular weakness and fatigue can cause changes in movement techniques. These changes may be related to limited ability to control mechanical loads and mechanical energy transmission to joints and passive structures.

  18. Usage of DNA Fingerprinting Technology for Quality Control in Molecular Lab Bench Work.

    Science.gov (United States)

    McIntosh, Linda Y; Lal, Janella E; Qin, Dahui

    2018-01-01

    One of the major quality assurance (QA) goals in many molecular laboratories is to avoid sample pipetting errors on the lab bench; especially when pipetting into multiwell plates. A pipetting error can cause a switch in patient samples, which can lead to recording the wrong results for the patient samples involved. Such pipetting errors are difficult to identify when it happens in lab bench work. DNA fingerprinting is a powerful tool in determining sample identities. Our laboratory has explored the usage of this technology in our QA process and successfully established that DNA fingerprinting can be used to monitor possible sample switch in gene rearrangement lab bench work. We use florescent light to quench the florescence in the gene rearrangement polymerase chain reaction products. After that, DNA fingerprinting technology is used to identify the sample DNA in the gene rearrangement polymerase chain reaction plate. The result is compared with the corresponding patient's blood sample DNA to determine whether there is a sample switch during the lab bench work.

  19. Development of remote data acquisition system based on OPC for brake test bench

    Science.gov (United States)

    Wang, Yiwei; Wu, Mengling; Tian, Chun; Ma, Tianhe

    2017-08-01

    The 1:1 train brake system test bench can be used to carry out brake-related adhesion-slid control, stability test, noise test and dynamic test. To collect data of the test bench, a data acquisition method is needed. In this paper, the remote data acquisition system of test bench is built by LabVIEW based on OPC technology. Unlike the traditional hardwire way connecting PLC acquisition module with sensors, the novel method is used to collect data and share them through the internal LAN built by Ethernet switches, which avoids the complex wiring interference in an easy, efficient and flexible way. The system has been successfully applied to the data acquisition activities of the comprehensive brake system test bench of CRRC Nanjing Puzhen Haitai Brake Equipment Co., Ltd., and the relationship test between the adhesion coefficient and the slip-ratio is realized. The speed signal, torque signal and brake disc temperature can be collected and displayed. The results show that the system is reliable, convenient, and efficient, and can meet the requirements of data acquisition.

  20. The effect of active recovery on power performance during the bench press exercise.

    Science.gov (United States)

    Lopes, Felipe A S; Panissa, Valéria L G; Julio, Ursula F; Menegon, Elton M; Franchini, Emerson

    2014-03-27

    The objective of this study was to verify the effect of active and passive recovery on blood lactate concentration and power performance. Twelve male subjects were submitted to a maximal strength test in the the bench press, a maximal aerobic test in the bench step, and to four sets of bench press exercise performed as fast and as long as possible, using 80% of maximal strength when active or passive recovery was performed. The maximum number of repetitions, mean and peak power in eccentric and concentric phases were computed and blood lactate concentration was measured. Comparisons for the variables were made using a two-way variance analysis (recovery type and set numer) with repeated measures in the second factor. When significant differences were detected (p 2, 3, and 4; 2 > 3 and 4; 3 > 4). Mean and peak power in both eccentric and concentric phases also differed across sets (1 > 2, 3, and 4; 2 > 4). There was also a main effect for the recovery type, with lower values (p bench press exercise.

  1. Recovery of pectoralis major and triceps brachii after bench press exercise.

    Science.gov (United States)

    Ferreira, Diogo V; Gentil, Paulo; Soares, Saulo Rodrigo Sampaio; Bottaro, Martim

    2017-11-01

    The present study evaluated and compared the recovery of pectoralis major (PM) and triceps brachii (TB) muscles of trained men after bench press exercise. Eighteen volunteers performed eight sets of bench press exercise to momentary muscle failure and were evaluated for TB and PM peak torque and total work on an isokinetic dynamometer. PM peak torque and total work remained lower than baseline for 72 and 96 h, respectively. TB peak torque was only different from baseline immediately post training, while total work was significantly lower than baseline immediately and 48 h after training. Normalized peak torque values were only different between TB and PM at 48 h after training. Considering the small and nonsignificant difference between the recovery of TB and PM muscles, the results suggest that bench press exercise may promote a similar stress on these muscles. Muscle Nerve 56: 963-967, 2017. © 2016 Wiley Periodicals, Inc.

  2. An elegant Breadboard of the optical bench for eLISA/NGO

    Science.gov (United States)

    d'Arcio, Luigi; Bogenstahl, Johanna; Diekmann, Christian; Fitzsimons, Ewan D.; Heinzel, Gerhard; Hogenhuis, Harm; Killow, Christian J.; Lieser, Maike; Nikolov, Susanne; Perreur-Lloyd, Michael; Pijnenburg, Joep; Robertson, David I.; Taylor, Alasdair; Tröbs, Michael; Ward, Harry; Weise, Dennis

    2017-11-01

    The Laser Interferometer Space Antenna, as well as its reformulated European-only evolution, the New Gravitational-Wave Observatory, both employ heterodyne laser interferometry on million kilometer scale arm lengths in a triangular spacecraft formation, to observe gravitational waves at frequencies between 3 × 10-5 Hz and 1 Hz. The Optical Bench as central payload element realizes both the inter-spacecraft as well as local laser metrology with respect to inertial proof masses, and provides further functions, such as point-ahead accommodation, acquisition sensing, transmit beam conditioning, optical power monitoring, and laser redundancy switching. These functions have been combined in a detailed design of an Optical Bench Elegant Breadboard, which is currently under assembly and integration. We present an overview of the realization and current performances of the Optical Bench subsystems, which employ ultraprecise piezo mechanism, ultrastable assembly techniques, and shot noise limited RF detection to achieve translation and tilt metrology at Picometer and Nanoradian noise levels.

  3. Machine Shop I. Learning Activity Packets (LAPs). Section C--Hand and Bench Work.

    Science.gov (United States)

    Oklahoma State Board of Vocational and Technical Education, Stillwater. Curriculum and Instructional Materials Center.

    This document contains two learning activity packets (LAPs) for the "hand and bench work" instructional area of a Machine Shop I course. The two LAPs cover the following topics: hand and bench work and pedestal grinder. Each LAP contains a cover sheet that describes its purpose, an introduction, and the tasks included in the LAP;…

  4. ReaderBench: An Integrated Cohesion-Centered Framework

    NARCIS (Netherlands)

    Dascalu, Mihai; Stavarache, Lucia Larise; Dessus, Philippe; Trausan-Matu, Stefan; McNamara, Danielle S.; Bianco, Maryse

    2015-01-01

    Dascalu, M., Stavarache, L.L., Dessus, P., Trausan-Matu, S., McNamara, D.S., & Bianco, M. (2015). ReaderBench: An Integrated Cohesion-Centered Framework. In G. Conole, T. Klobucar, C. Rensing, J. Konert & É. Lavoué (Eds.), 10th European Conf. on Technology Enhanced Learning (pp. 505–508). Toledo,

  5. Improvement of bench life-tests for automotive batteries

    Science.gov (United States)

    Richter, G.

    A common method for rating the endurance of automotive batteries is the bench life-test according to DIN, IEC, SAE or JIS. With an increasing number of maintenance-free batteries on the market, the application of these tests becomes more problematic. This is due to a step-by-step capacity decline during cycling if the content of autimony in the grid-alloy is decreased. The degradation in performance is caused by the phenomenon of acid stratification. Because this debilitating effect occurs only rarely in service (vehicle movement) if charging and discharging is well balanced, there is a need for a new bench life-test with conditions that are more representative of practical conditions. Research has shown that the main changes should be: (i) an accelerated (moved) battery during cycling; (ii) slightly lower charging or discharging capacity amplitude, also with a lower mean value.

  6. Importance of Upper-Limb Inertia in Calculating Concentric Bench Press Force

    OpenAIRE

    RAMBAUD, O; RAHMANI, A; MOYEN, B; BOURDIN, M

    2008-01-01

    The purpose of this study was to investigate the influence of upper-limb inertia on the force-velocity relationship and maximal power during concentric bench press exercise. Reference peak force values (Fpeakp) measured with a force plate positioned below the bench were compared to those measured simultaneously with a kinematic device fixed on the barbell by taking (Fpeakt) or not taking (Fpeakb) upper-limb inertia into account. Thirteen men (27.8 6 4.1 years, 184.6 6 5.5 cm, 99.5 6 18.6 kg) ...

  7. Postactivation potentiation: effect of various recovery intervals on bench press power performance.

    Science.gov (United States)

    Ferreira, Sandra Lívia de Assis; Panissa, Valéria Leme Gonçalves; Miarka, Bianca; Franchini, Emerson

    2012-03-01

    Postactivation potentiation (PAP) is a strategy used to improve performance in power activities. The aim of this study was to determine if power during bench press exercise was increased when preceded by 1 repetition maximum (1RM) in the same exercise and to determine which time interval could optimize PAP response. For this, 11 healthy male subjects (age, 25 ± 4 years; height, 178 ± 6 cm; body mass, 74 ± 8 kg; bench press 1RM, 76 ± 19 kg) underwent 6 sessions. Two control sessions were conducted to determine both bench press 1RM and power (6 repetitions at 50% 1RM). The 4 experimental sessions were composed of a 1RM exercise followed by power sets with different recovery intervals (1, 3, 5, and 7 minutes), performed on different days, and determined randomly. Power values were measured via Peak Power equipment (Cefise, Nova Odessa, São Paulo, Brazil). The conditions were compared using an analysis of variance with repeated measures, followed by a Tukey test. The significance level was set at p bench press and that such a strategy could be applied as an interesting alternative to enhance the performance in tasks aimed at increasing upper-body power performance.

  8. Electromyographic activity and 6RM strength in bench press on stable and unstable surfaces.

    Science.gov (United States)

    Saeterbakken, Atle H; Fimland, Marius S

    2013-04-01

    The purpose of the study was to compare 6-repetition maximum (6RM) loads and muscle activity in bench press on 3 surfaces, namely, stable bench, balance cushion, and Swiss ball. Sixteen healthy, resistance-trained men (age 22.5 ± 2.0 years, stature 1.82 ± 6.6 m, and body mass 82.0 ± 7.8 kg) volunteered for 3 habituation/strength testing sessions and 1 experimental session. In randomized order on the 3 surfaces, 6RM strength and electromyographic activity of pectoralis major, deltoid anterior, biceps brachii, triceps brachii, rectus abdominis, oblique external and erector spinae were assessed. Relative to stable bench, the 6RM strength was approximately 93% for balance cushion (p ≤ 0.001) and approximately 92% for Swiss ball (p = 0.008); the pectoralis major electromyographic (EMG) activity was approximately 90% using the balance cushion (p = 0.080) and approximately 81% using Swiss ball (p = 0.006); the triceps EMG was approximately 79% using the balance cushion (p = 0.028) and approximately 69% using the Swiss ball (p = 0.002). Relative to balance cushion, the EMG activity in pectoralis, triceps, and erector spinae using Swiss ball was approximately 89% (p = 0.016), approximately 88% (p = 0.014) and approximately 80% (p = 0.020), respectively. In rectus abdominis, the EMG activity relative to Swiss ball was approximately 69% using stable bench (p = 0.042) and approximately 65% using the balance cushion (p = 0.046). Similar EMG activities between stable and unstable surfaces were observed for deltoid anterior, biceps brachii, and oblique external. In conclusion, stable bench press had greater 6RM strength and triceps and pectoralis EMG activity compared with the unstable surfaces. These findings have implications for athletic training and rehabilitation, because they demonstrate an inferior effect of unstable surfaces on muscle activation of prime movers and strength in bench press. If an unstable surface in bench press is desirable, a balance cushion should

  9. RPE and Velocity Relationships for the Back Squat, Bench Press, and Deadlift in Powerlifters.

    Science.gov (United States)

    Helms, Eric R; Storey, Adam; Cross, Matt R; Brown, Scott R; Lenetsky, Seth; Ramsay, Hamish; Dillen, Carolina; Zourdos, Michael C

    2017-02-01

    Helms, ER, Storey, A, Cross, MR, Browm, SR, Lenetsky, S, Ramsay, H, Dillen, C, and Zourdos, MC. RPE and velocity relationships for the back squat, bench press, and deadlift in powerlifters. J Strength Cond Res 31(2): 292-297, 2017-The purpose of this study was to compare average concentric velocity (ACV) and rating of perceived exertion (RPE) based on repetitions in reserve on the squat, bench press, and deadlift. Fifteen powerlifters (3 women and 12 men, mean age 28.4 ± 8.5 years) worked up to a one repetition maximum (1RM) on each lift. Rating of perceived exertion was recorded on all sets, and the ACV was recorded for all sets performed at 80% of estimated 1RM and higher, up to 1RM. Rating of perceived exertion at 1RM on squat, bench press, and deadlift was 9.6 ± 0.5, 9.7 ± 0.4, and 9.6 ± 0.5, respectively and was not significantly different (p > 0.05). The ACV at 1RM on squat, bench press and deadlift was 0.23 ± 0.05, 0.10 ± 0.04, and 0.14 ± 0.05 m·second, respectively. Squat was faster than both bench press and deadlift (p > 0.001), and deadlift was faster than bench press (p = 0.05). Very strong relationships (r = 0.88-0.91) between percentage 1RM and RPE were observed on each lift. The ACV showed strong (r = -0.79 to -0.87) and very strong (r = -0.90 to 92) inverse relationships with RPE and percentage 1RM on each lift, respectively. We conclude that RPE may be a useful tool for prescribing intensity for squat, bench press, and deadlift in powerlifters, in addition to traditional methods such as percentage of 1RM. Despite high correlations between percentage 1RM and ACV, a "velocity load profile" should be developed to prescribe intensity on an individual basis with appropriate accuracy.

  10. BWR Mark I pressure suppression study: bench mark experiments

    International Nuclear Information System (INIS)

    Lai, W.; McCauley, E.W.

    1977-01-01

    Computer simulations representative of the wetwell of Mark I BWR's have predicted pressures and related phenomena. However, calculational predictions for purposes of engineering decision will be possible only if the code can be verified, i.e., shown to compute in accord with measured values. Described in the report is a set of single downcomer spherical flask bench mark experiments designed to produce quantitative data to validate various air-water dynamic computations; the experiments were performed since relevant bench mark data were not available from outside sources. Secondary purposes of the study were to provide a test bed for the instrumentation and post-experiment data processing techniques to be used in the Laboratory's reactor safety research program and to provide additional masurements for the air-water scaling study

  11. Retrofit designs for small bench-type blood cell counters.

    Science.gov (United States)

    Ferris, C D

    1991-01-01

    This paper describes several retrofit designs to correct operational problems associated with small bench-type blood cell counters. Replacement electronic circuits as well as modifications to the vacuum systems are discussed.

  12. Test bench HEATREC for heat loss measurement on solar receiver tubes

    Science.gov (United States)

    Márquez, José M.; López-Martín, Rafael; Valenzuela, Loreto; Zarza, Eduardo

    2016-05-01

    In Solar Thermal Electricity (STE) plants the thermal energy of solar radiation is absorbed by solar receiver tubes (HCEs) and it is transferred to a heat transfer fluid. Therefore, heat losses of receiver tubes have a direct influence on STE plants efficiency. A new test bench called HEATREC has been developed by Plataforma Solar de Almería (PSA) in order to determinate the heat losses of receiver tubes under laboratory conditions. The innovation of this test bench consists in the possibility to determine heat losses under controlled vacuum.

  13. A new BETSI test bench at CEA/Saclay

    International Nuclear Information System (INIS)

    Nyckees, S.; Adroit, G.; Delferriere, O.; Duperrier, R.; Gauthier, Y.; Gobin, R.; Harrault, F.; Mateo, C.M.; Napoly, O.; Pottin, B.; Sauce, Y.; Senee, F.; Tuske, O.; Vacher, T.

    2012-01-01

    In the nineties, CEA has undertaken to develop the production of high intensity light ion beams from plasma generated by electron cyclotron resonance (ECR). Important results were obtained with the SILHI source in pulsed or continuous mode. Presently, CEA/Saclay is now involved in the construction of different injectors dedicated to large infrastructures like IFMIF or SPIRAL2. Other installations are also interested by high intensity ion sources like ESS or FAIR. To improve and test new sources, a new test bench named BETSI (Banc d'Etudes et de Tests des Sources d'Ions) has been operating for several years. Low energy beam line diagnostics consist of a Faraday cup, cameras and a species analyzer. The SILHI emittance scanner can also be installed on the beam line. On this test bench, different permanent magnet source configurations are tested. The paper is followed by the associated poster. (authors)

  14. The R and D D's bearing test benches

    International Nuclear Information System (INIS)

    Vialettes, J.M.

    1997-01-01

    In power generation plants, rotating machines are involved in energy transformation processes and safety systems. The bearings supporting the rotors and the thrust bearings play a crucial role in the reliability of these machines. The phenomena encountered straddle several disciplines: hydrodynamics, tribology, thermomechanics, materials and vibrations in a specific environment, namely: thin fluid film, solid mechanical components and shaft rotation. Means of analysing the behaviour of these components (bearings and thrust bearings) have been developed and implemented. These consists of the EDYOS (Etude Dynamique des Organes de Supportage) code for dynamically studying bearing devices and several related bench tests. In reality, in order to understand the complex physical phenomena encountered in these components, it is vital to carry out analyses and experimental validations. Since these investigations cannot be carried out on actual machines, test benches have been built which can subject the sample bearings to the equivalent stresses. (author)

  15. Neuromuscular Control During the Bench Press Movement in an Elite Disabled and Able-Bodied Athlete

    Directory of Open Access Journals (Sweden)

    Gołaś Artur

    2017-12-01

    Full Text Available The disabled population varies significantly in regard to physical fitness, what is conditioned by the damage to the locomotor system. Recently there has been an increased emphasis on the role of competitive sport in enhancing health and the quality of life of individuals with disability. One of the sport disciplines of Paralympics is the flat bench press. The bench press is one of the most popular resistance exercises used for the upper body in healthy individuals. It is used not only by powerlifters, but also by athletes in most strength-speed oriented sport disciplines. The objective of the study was to compare neuromuscular control for various external loads (from 60 to 100% 1RM during the flat bench press performed by an elite able-bodied athlete and an athlete with lower limb disability. The research project is a case study of two elite bench press athletes with similar sport results: an able-bodied athlete (M.W., age 34 years, body mass 103 kg, body height 1.72 m, 1RM in the flat bench press 200 kg and a disabled athlete (M.T., age 31 years, body mass 92 kg, body height 1.70 m, 1RM in the flat bench press 190 kg. The activity was recorded for four muscles: pectoralis major (PM, anterior deltoid (AD, as well as for the lateral and long heads of the triceps brachii (TBlat and TBlong. The T-test revealed statistically significant differences between peak activity of all the considered muscles (AD with p = 0.001; PM with p = 0.001; TBlat with p = 0.0021 and TBlong with p = 0.002 between the 2 athletes. The analysis of peak activity differences of M.W and M.T. in relation to the load revealed statistically significant differences for load changes between: 60 to 100% 1RM (p = 0.007, 70 to 100% 1RM (p = 0.016 and 80 to 100% 1RM (p = 0.032. The flat bench press performed without legs resting firmly on the ground leads to the increased engagement of upper body muscles and to their greater activation. Isolated initial positions can be used to

  16. Neuromuscular Control During the Bench Press Movement in an Elite Disabled and Able-Bodied Athlete.

    Science.gov (United States)

    Gołaś, Artur; Zwierzchowska, Anna; Maszczyk, Adam; Wilk, Michał; Stastny, Petr; Zając, Adam

    2017-12-01

    The disabled population varies significantly in regard to physical fitness, what is conditioned by the damage to the locomotor system. Recently there has been an increased emphasis on the role of competitive sport in enhancing health and the quality of life of individuals with disability. One of the sport disciplines of Paralympics is the flat bench press. The bench press is one of the most popular resistance exercises used for the upper body in healthy individuals. It is used not only by powerlifters, but also by athletes in most strength-speed oriented sport disciplines. The objective of the study was to compare neuromuscular control for various external loads (from 60 to 100% 1RM) during the flat bench press performed by an elite able-bodied athlete and an athlete with lower limb disability. The research project is a case study of two elite bench press athletes with similar sport results: an able-bodied athlete (M.W., age 34 years, body mass 103 kg, body height 1.72 m, 1RM in the flat bench press 200 kg) and a disabled athlete (M.T., age 31 years, body mass 92 kg, body height 1.70 m, 1RM in the flat bench press 190 kg). The activity was recorded for four muscles: pectoralis major (PM), anterior deltoid (AD), as well as for the lateral and long heads of the triceps brachii (TBlat and TBlong). The T-test revealed statistically significant differences between peak activity of all the considered muscles (AD with p = 0.001; PM with p = 0.001; TBlat with p = 0.0021 and TBlong with p = 0.002) between the 2 athletes. The analysis of peak activity differences of M.W and M.T. in relation to the load revealed statistically significant differences for load changes between: 60 to 100% 1RM (p = 0.007), 70 to 100% 1RM (p = 0.016) and 80 to 100% 1RM (p = 0.032). The flat bench press performed without legs resting firmly on the ground leads to the increased engagement of upper body muscles and to their greater activation. Isolated initial positions can be used to generate

  17. Validity of the Myotest® in measuring force and power production in the squat and bench press.

    Science.gov (United States)

    Comstock, Brett A; Solomon-Hill, Glenn; Flanagan, Shawn D; Earp, Jacob E; Luk, Hui-Ying; Dobbins, Kathryn A; Dunn-Lewis, Courtenay; Fragala, Maren S; Ho, Jen-Yu; Hatfield, Disa L; Vingren, Jakob L; Denegar, Craig R; Volek, Jeff S; Kupchak, Brian R; Maresh, Carl M; Kraemer, William J

    2011-08-01

    The purpose of this study was to verify the concurrent validity of a bar-mounted Myotest® instrument in measuring the force and power production in the squat and bench press exercises when compared to the gold standard of a computerized linear transducer and force platform system. Fifty-four men (bench press: 39-171 kg; squat: 75-221 kg) and 43 women (bench press: 18-80 kg; squat: 30-115 kg) (age range 18-30 years) performed a 1 repetition maximum (1RM) strength test in bench press and squat exercises. Power testing consisted of the jump squat and the bench throw at 30% of each subject's 1RM. During each measurement, both the Myotest® instrument and the Celesco linear transducer of the directly interfaced BMS system (Ballistic Measurement System [BMS] Innervations Inc, Fitness Technology force plate, Skye, South Australia, Australia) were mounted to the weight bar. A strong, positive correlation (r) between the Myotest and BMS systems and a high correlation of determination (R2) was demonstrated for bench throw force (r = 0.95, p bench throw power (r = 0.96, p < 0.05) (R2 = 0.93); squat jump force (r = 0.98, p < 0.05) (R2 = 0.97); and squat jump power (r = 0.91, p < 0.05) (R2 = 0.82). In conclusion, when fixed on the bar in the vertical axis, the Myotest is a valid field instrument for measuring force and power in commonly used exercise movements.

  18. Effects of interset whole-body vibration on bench press resistance training in trained and untrained individuals.

    Science.gov (United States)

    Timon, Rafael; Collado-Mateo, Daniel; Olcina, Guillermo; Gusi, Narcis

    2016-03-01

    Previous studies have demonstrated positive effects of acute vibration exercise on concentric strength and power, but few have observed the effects of vibration exposure on resistance training. The aim of this study was to verify the effects of whole body vibration applied to the chest via hands on bench press resistance training in trained and untrained individuals. Nineteen participants (10 recreationally trained bodybuilders and 9 untrained students) performed two randomized sessions of resistance training on separate days. Each strength session consisted of 3 bench press sets with a load of 75% 1RM to failure in each set, with 2 minutes' rest between sets. All subjects performed the same strength training with either, vibration exposure (12 Hz, 4 mm) of 30 seconds immediately before each bench press set or without vibration. Number of total repetitions, kinematic parameters, blood lactate and perceived exertion were analyzed. In the untrained group, vibration exposure caused a significant increase in the mean velocity (from 0.36±0.02 to 0.39±0.03 m/s) and acceleration (from 0.75±0.10 to 0.86±0.09 m/s2), as well as a decrease in perceived effort (from 8±0.57 to 7.35±0.47) in the first bench press set, but no change was observed in the third bench press set. In the recreationally trained bodybuilders, vibration exposure did not cause any improvement on the performance of bench press resistance training. These results suggest that vibration exposure applied just before the bench press exercise could be a good practice to be implemented by untrained individuals in resistance training.

  19. Study on saccharification of cellulosic wastes with bench scale test plant, (5)

    International Nuclear Information System (INIS)

    Kasai, Noboru; Tamada, Masao; Kumakura, Minoru

    1989-05-01

    This report completed the results that were obtained on the studies of continuous saccharification of radiation pretreated chaff with a saccharification equipment unit of bench scale test plant for cellulosic wastes. The problem on the continuous saccharification in bench scale and its countermeasure were clarified. The glucose concentration obtained in the continuous saccharification was examined from the point of a scale up effect. It was found that there are not a scale up effect between flask scale (100 ml) and bench scale (50 l) and then the same concentration of glucose was obtained in both scales. It was clarified that the contamination of the process let decrease markedly the concentration of produced glucose solution and brings on a large trouble for the saccharification. The addition of 1 % ethyl acetate made it possible to prevent the contamination of the saccharification process in flask scale. However, in the case of continuous saccharification in bench scale, the addition of ethyl acetate in nitrogen gas atmosphere was necessary to prevent the contamination. It was found that the solution of 1.7 % glucose concentration was continuously produced in the continuous saccharification with the most longest period for 26 days. It was, also, suggested that the selection of a suitable retention time is necessary to attain a high glucose productivity in the continuous saccharification. (author)

  20. Bench-scale treatability studies for simulated incinerator scrubber blowdown containing radioactive cesium and strontium

    International Nuclear Information System (INIS)

    Coroneos, A.C.; Taylor, P.A.; Arnold, W.D. Jr.; Bostick, D.A.; Perona, J.J.

    1994-12-01

    The purpose of this report is to document the results of bench-scale testing completed to remove 137 Cs and 90 Sr from the Oak Ridge K-25 Site Toxic Substances Control Act (TSCA) Incinerator blowdown at the K-25 Site Central Neutralization Facility, a wastewater treatment facility designed to remove heavy metals and uranium from various wastewaters. The report presents results of bench-scale testing using chabazite and clinoptilolite zeolites to remove cesium and strontium; using potassium cobalt ferrocyanide (KCCF) to remove cesium; and using strontium chloride coprecipitation, sodium phosphate coprecipitation, and calcium sulfate coprecipitation to remove strontium. Low-range, average-range, and high-range concentration blowdown surrogates were used to complete the bench-scale testing

  1. Cometabolic biotreatment of TCE-contaminated groundwater: Laboratory and bench-scale development studies

    International Nuclear Information System (INIS)

    Donaldson, T.L.; Jennings, H.L.; Lucero, A.J.; Strandberg, G.W.; Morris, M.I.; Palumbo, A.V.; Boerman, P.A.; Tyndall, R.L.

    1992-01-01

    The Oak Ridge National Laboratory is conducting a demonstration of two cometabolic technologies for biotreatment of groundwater contaminated with trichloroethylene (TCE) and other organics. Technologies based on methanotrophic (methane-utilizing) and toluene-degrading microorganisms will be compared side-by-side on the same groundwater stream. Laboratory and bench-scale bioreactor studies have been conducted to guide selection of microbial cultures and operating conditions for the field demonstration. This report presents the results of the laboratory and bench-scale studies for the methanotrophic system

  2. Application of bench-scale biocalorimetry to photoautotrophic cultures

    NARCIS (Netherlands)

    Janssen, M.; Patino, R.; Stockar, von U.

    2005-01-01

    Bench-scale biocalorimetry (=1 L) allows for the determination of the metabolic heat flow during bioprocesses under complete control of all process conditions for extended periods of time. It can be combined with a number of on-line and off-line measurement techniques. This combination can

  3. Fatigue effects upon sticking region and electromyography in a six-repetition maximum bench press.

    Science.gov (United States)

    van den Tillaar, Roland; Saeterbakken, Atle Hole

    2013-01-01

    The aim of the study was to examine the sticking region and concomitant neuromuscular activation of the prime movers during six-repetition maximum (RM) bench pressing. We hypothesised that both peak velocities would decrease and that the electromyography (EMG) of the prime movers (deltoid, major pectoralis and triceps) would increase during the pre-sticking and sticking region during the six repetitions due to fatigue. Thirteen resistance-trained males (age 22.8 ± 2.2 years, stature 1.82 ± 0.06 m, body mass 83.4 ± 7.6 kg) performed 6-RM bench presses. Barbell kinematics and EMG activity of pectoralis major, deltoid anterior, and triceps brachii during the pre-, sticking and post-sticking region of each repetition in a 6-RM bench press were analysed. For both the sticking as the post-sticking region, the time increased significantly from the first to the sixth repetition. Vertical barbell height at the start of sticking region was lower, while the height at the end of the sticking region and post-sticking region did not change during the six repetitions. It was concluded that in 6-RM bench pressing performance, the sticking region is a poor mechanical force region due to the unchanged barbell height at the end of the sticking region. Furthermore, when fatigue occurs, the pectoralis and the deltoid muscles are responsible for surpassing the sticking region as indicated by their increased activity during the pre- and sticking region during the six-repetitions bench press.

  4. Effects of Variable Resistance Using Chains on Bench Throw Performance in Trained Rugby Players.

    Science.gov (United States)

    Godwin, Mark S; Fernandes, John F T; Twist, Craig

    2018-04-01

    Godwin, MS, Fernandes, JFT, and Twist, C. Effects of variable resistance using chains on bench throw performance in trained rugby players. J Strength Cond Res 32(4): 950-954, 2018-This study sought to determine the effects of variable resistance using chain resistance on bench throw performance. Eight male rugby union players (19.4 ± 2.3 years, 88.8 ± 6.0 kg, 1RM 105.6 ± 17.0 kg) were recruited from a national league team. In a randomized crossover design, participant's performed 3 bench throws at 45% one repetition maximum (1RM) at a constant load (no chains) or a variable load (30% 1RM constant load and 15% 1RM variable load; chains) with 7 days between conditions. For each repetition, the peak and mean velocity, peak power, peak acceleration, and time to peak velocity were recorded. Differences in peak and mean power were very likely trivial and unclear between the chain and no chain conditions, respectively. Possibly greater peak and likely greater mean bar velocity were accompanied by likely to most likely greater bar velocity between 50 and 400 ms from initiation of bench press in the chain condition compared with the no chain condition. Accordingly, bar acceleration was very likely greater in the chain condition compared with the no chain condition. In conclusion, these results show that the inclusion of chain resistance can acutely enhance several variables in the bench press throw and gives support to this type of training.

  5. Stem Cell Transplantation from Bench to Bedside

    Indian Academy of Sciences (India)

    Table of contents. Stem Cell Transplantation from Bench to Bedside · Slide 2 · Slide 3 · Slide 4 · Principles of an allogeneic stem cell transplant · Principle of an allogeneic stem cell transplant · Principle of an autologous Stem Cell Transplant · Slide 8 · Conditioning · Slide 10 · Slide 11 · Stem Cell Transplantation · Slide 13.

  6. Simulation-based rhomboid flap skills training during medical education: comparing low- and high-fidelity bench models.

    Science.gov (United States)

    Denadai, Rafael; Saad-Hossne, Rogerio; Raposo-Amaral, Cassio Eduardo

    2014-11-01

    To assess if the bench model fidelity interferes in the acquisition of rhomboid flap skills by medical students. Sixty novice medical students were randomly assigned to 5 practice conditions with instructor-directed Limberg rhomboid flap skills training: didactic materials (control group 1), low-fidelity rubberized line (group 2) or ethylene-vinyl acetate (group 3) bench models; high-fidelity chicken leg skin (group 4) or pig foot skin (group 5) bench models. Pretests and posttests were applied, and Global Rating Scale, effect size, and self-perceived confidence were used to evaluate all flap performances. Medical students from groups 2 to 5 showed better flap performances based on the Global Rating Scale (all P 0.05). The magnitude of the effect was considered large (>0.80) in all measurements. There was acquisition of rhomboid flap skills regardless of bench model fidelity.

  7. Automatic integrated testing bench for tubes in translation

    International Nuclear Information System (INIS)

    Dufayet, J.P.; Perdijon, J.

    1976-01-01

    All the nondestructive tests required for receiving the cladding tubes intended for fast nuclear reactor are integrated on this bench: quality control by eddy currents and ultra-sounds, thickness and (inner and outer) diameter measurement. The linear displacement of the tube allows very high rates to be attained [fr

  8. Cometabolic biotreatment of TCE-contaminated groundwater - Laboratory and bench-scale development studies

    Energy Technology Data Exchange (ETDEWEB)

    Donaldson, T L; Palumbo, A V; Boerman, P A; Jennings, H L; Lucero, A J; Tyndall, R L; Strandberg, G W; Morris, M I [Oak Ridge National Laboratory, Oak Ridge, TN (United States)

    1992-07-01

    The Oak Ridge National Laboratory is conducting a demonstration of two cometabolic technologies for biotreatment of groundwater contaminated with trichloroethylene (TCE) and other organics. Technologies based on methanotrophic (methane-utilizing) and toluene-degrading microorganisms will be compared side-by-side on the same groundwater stream. Laboratory and bench-scale bioreactor studies have been conducted to guide selection of microbial cultures and operating conditions for the field demonstration. This report presents the results of the laboratory and bench-scale studies for the methanotrophic system. (author)

  9. Effects of a 6-Week Bench Press Program Using the Freak Bar in a Sample of Collegiate Club Powerlifters.

    Science.gov (United States)

    Ghigiarelli, Jamie J; Pelton, Luke M; Gonzalez, Adam M; Fulop, Andras M; Gee, Joshua Y; Sell, Katie M

    2018-04-01

    Ghigiarelli, JJ, Pelton, LM, Gonzalez, AM, Fulop, AM, Gee, JY, and Sell, KM. Effects of a 6-week bench press program using the freak bar in a sample of collegiate club powerlifters. J Strength Cond Res 32(4): 938-949, 2018-Powerlifters train using specialty bars for unstable load (UL) training. For the bench press, the acute effects of UL are mixed, with few studies that examine training interventions. The purpose of this study was to examine the effects of a 6-week bench press training program that uses the Freak Bar (FB) as compared to a traditional barbell (TB) on maximum bench press, peak force, and peak impulse. Seven men and 3 women (21 ± 2.0 years, 172.2 ± 2.9 cm, and 95.3 ± 20.3 kg) were required to bench press 2 days per week as part of a structured program. On the second bench press day, the FB and TB groups performed 3-position pause bench presses at 60-70% one repetition maximum (1RM). One repetition maximum, peak force, and peak impulse were measured before test and after test after the 6-week program. Peak force and peak impulse were tested at 3 bench positions, including the presticking, sticking, and poststicking points, defined by the distance of the barbell from the chest. Posttraining 1RM for the FB group and TB group increased 6.7% (6.78 ± 1.6 kg, p = 0.006) and 4.3% (4.5 ± 2.7 kg, p = 0.23), respectively, with no significant differences between the groups (p = 0.589, ηp = 0.044). There were no significant differences between the groups at each bench position for peak force (p = 0.606) or peak impulse (p = 0.542). Freak Bar can be an alternative for improving maximum strength and peak force but is not significantly better than TB training when performing the 3-position pause bench press.

  10. Complex analysis of movement in evaluation of flat bench press performance.

    Science.gov (United States)

    Król, Henryk; Golas, Artur; Sobota, Grzegorz

    2010-01-01

    The complex methodology of investigations was applied to study a movement structure on bench press. We have checked the usefulness of multimodular measuring system (SMART-E, BTS company, Italy) and a special device for tracking the position of barbell (pantograph). Software Smart Analyser was used to create a database allowing chosen parameters to be compared. The results from different measuring devices are very similar, therefore the replacement of many devices by one multimodular system is reasonable. In our study, the effect of increased barbell load on the values of muscles activity and bar kinematics during the flat bench press movement was clearly visible. The greater the weight of a barbell, the greater the myoactivity of shoulder muscles and vertical velocity of the bar. It was also confirmed the presence of the so-called sticking point (period) during the concentric phase of the bench press. In this study, the initial velocity of the barbell decreased (v(min)) not only under submaximal and maximal loads (90 and 100% of the one repetition maximum; 1-RM), but also under slightly lighter weights (70 and 80% of 1-RM).

  11. Muscular outputs during dynamic bench press under stable versus unstable conditions.

    Science.gov (United States)

    Koshida, Sentaro; Urabe, Yukio; Miyashita, Koji; Iwai, Kanzunori; Kagimori, Aya

    2008-09-01

    Previous studies have suggested that resistance training exercise under unstable conditions decreases the isometric force output, yet little is known about its influence on muscular outputs during dynamic movement. The objective of this study was to investigate the effect of an unstable condition on power, force, and velocity outputs during the bench press. Twenty male collegiate athletes (mean age, 21.3 +/- 1.5 years; mean height, 167.7 +/- 7.7 cm; mean weight, 75.9 +/- 17.5 kg) participated in this study. Each subject attempted 3 sets of single bench presses with 50% of 1 repetition maximum (1RM) under a stable condition with a flat bench and an unstable condition with a Swiss ball. Acceleration data were obtained with an accelerometer attached to the center of a barbell shaft, and peak outputs of power, force, and velocity were computed. Although significant loss of the peak outputs was found under the unstable condition (p velocity outputs, compared with previous findings. Such small reduction rates of muscular outputs may not compromise the training effect. Prospective studies are necessary to confirm whether the resistance training under an unstable condition permits the improvement of dynamic performance and trunk stability.

  12. Calibration bench of flowmeters; Banc d'etalonnage de debitmetres

    Energy Technology Data Exchange (ETDEWEB)

    Bremond, J; Da Costa, D; Calvet, A; Vieuxmaire, C

    1966-07-01

    This equipment is devoted to the comparison of signals from two turbines installed in the Cabri experimental loop. The signal is compared to the standard turbine. The characteristics and the performance of the calibration bench are presented. (A.L.B.)

  13. The effect of sodium bicarbonate ingestion on back squat and bench press exercise to failure.

    Science.gov (United States)

    Duncan, Michael J; Weldon, Anthony; Price, Michael J

    2014-05-01

    This study examined the acute effects of NaHCO3 ingestion on repetitions to failure and rating of perceived exertion in the back squat and bench press in trained men. Eight resistance-trained men took part in this double-blind, randomized crossover experimental study whereby they ingested NaHCO3 (0.3 g·kg(-1) body mass) or placebo (sodium chloride NaCl: 0.045 g·kg(-1) body mass) solution 60 minutes before completing a bout of resistance exercise (3 sets of bench press and back squat exercise to failure at an intensity of 80% 1 repetition maximum). Experimental conditions were separated by at least 48 hours. Participants completed more repetitions to failure in the back squat after NaHCO3 ingestion (p = 0.04) but not for bench press (p = 0.679). Mean ± SD of total repetitions was 31.3 ± 15.3 and 24.6 ± 16.2 for back squat and 28.7 ± 12.2 and 26.7 ± 10.2 for bench press in NaHCO3 and placebo conditions, respectively. Repetitions to failure decreased as set increased for the back squat and bench press (p = 0.001, both). Rating of perceived exertion significantly increased with set for the back squat and bench press (p = 0.002, both). There was no significant change in blood lactate across time or between conditions. There were however treatment × time interactions for blood pH (p = 0.014) and blood HCO3 concentration (p = 0.001). After ingestion, blood pH and HCO3 (p = 0.008) concentrations were greater for the NaHCO3 condition compared with the placebo condition (p < 0.001). The results of this study suggest that sodium bicarbonate ingestion can enhance resistance exercise performance using a repetition to failure protocol in the first exercise in a resistance exercise session.

  14. Diagnostics at JINR LHEP photogun bench

    International Nuclear Information System (INIS)

    Nozdrin, M.A.; Balalykin, N.I.; Minashkin, V.F.; Shirkov, G.D.

    2016-01-01

    The photoinjector electron beam quality dramatically depends on the laser driver beam quality. For laser beam diagnostics a 'virtual cathode' system was realized at the JINR LHEP photogun bench. The system allows one to image laser beam profile at the cathode. The AVINE software complex developed in DESY Zeuthen is being used for imaging. Equipment for emittance measurement using the slit method was installed. The original emittance calculation software EmCa was created and tested with the laser beam.

  15. Effect of bench time polymerization on depth of cure of dental composite resin

    Science.gov (United States)

    Harahap, K.; Yudhit, A.; Sari, F.

    2017-07-01

    The aim of this research was to investigate the effect of bench time before light cured polymerization on the depth of cure of dental composite resin. Nanofiller composite resin (Filtek Z350 XT,3M, ESPE,China) was used in this study. Sixty samples of nanofiller composite resin were made and divided into control and test groups with bench time for 0, 15, 30, 45, and 60 min. For the test group, composite resins were stored in refrigerator with 4°C temperatures. Meanwhile, for the control groups, the composite resin was stored at room temperature. The samples were prepared using metal mould with size diameter of 6 mm and 4 mm in thickness. Samples were cured for 20 s by using visible blue light curing unit. Part of samples that unpolymerized were removed by using a plastic spatula. The remaining parts of samples were measured by digital caliper and noted as depth of cure (mm). Data were analyzed to one-way ANOVA and LSD tests (p≤0.05). Results showed there was no significance differences between test groups (p=0.5). A 60 minutes bench time group showed the highest depth of cure value among test group, and it was almost similar with control group value. It can be concluded that longer bench time can increase the depth of cure of composite resin.

  16. PXIe-based LLRF architecture and versatile test bench for heavy ion linear acceleration

    OpenAIRE

    Jugo, I. Badillo J.; Portilla, J.; Feutchwanger, J.; Vicente, C. San; Etxebarria, V.

    2014-01-01

    This work describes the architecture of a digital LLRF system for heavy-ion acceleration developed under the specification of the projected future heavy-ion accelerator facility in Huelva, Spain. A prototype LLRF test bench operating at 80MHz in CW mode has been designed and built. The core LLRF control has been digitally implemented on a PXIe chassis, including an FPGA for digital signal processing and a real time controller. The test bench is completed with a good quality signal generator u...

  17. Dynamic balance abilities of collegiate men for the bench press.

    Science.gov (United States)

    Piper, Timothy J; Radlo, Steven J; Smith, Thomas J; Woodward, Ryan W

    2012-12-01

    This study investigated the dynamic balance detection ability of college men for the bench press exercise. Thirty-five college men (mean ± SD: age = 22.4 ± 2.76 years, bench press experience = 8.3 ± 2.79 years, and estimated 1RM = 120.1 ± 21.8 kg) completed 1 repetition of the bench press repetitions for each of 3 bar loading arrangements. In a randomized fashion, subjects performed the bench press with a 20-kg barbell loaded with one of the following: a balanced load, one 20-kg plate on each side; an imbalanced asymmetrical load, one 20-kg plate on one side and a 20-kg plate plus a 1.25-kg plate on the other side; or an imbalanced asymmetrical center of mass, 20-kg plate on one side and sixteen 1.25-kg plates on the other side. Subjects were blindfolded and wore ear protection throughout all testing to decrease the ability to otherwise detect loads. Binomial data analysis indicated that subjects correctly detected the imbalance of the imbalanced asymmetrical center of mass condition (p[correct detection] = 0.89, p < 0.01) but did not correctly detect the balanced condition (p[correct detection] = 0.46, p = 0.74) or the imbalanced asymmetrical condition (p[correct detection] = 0.60, p = 0.31). Although it appears that a substantial shift in the center of mass of plates leads to the detection of barbell imbalance, minor changes of the addition of 1.25 kg (2.5 lb) to the asymmetrical condition did not result in consistent detection. Our data indicate that the establishment of a biofeedback loop capable of determining balance detection was only realized under a high degree of imbalance. Although balance detection was not present in either the even or the slightly uneven loading condition, the inclusion of balance training for upper body may be futile if exercises are unable to establish such a feedback loop and thus eliciting an improvement of balance performance.

  18. Data Quality Objectives For Selecting Waste Samples For Bench-Scale Reformer Treatability Studies

    International Nuclear Information System (INIS)

    Banning, D.L.

    2011-01-01

    This document describes the data quality objectives to select archived samples located at the 222-S Laboratory for Bench-Scale Reforming testing. The type, quantity, and quality of the data required to select the samples for Fluid Bed Steam Reformer testing are discussed. In order to maximize the efficiency and minimize the time to treat Hanford tank waste in the Waste Treatment and Immobilization Plant, additional treatment processes may be required. One of the potential treatment processes is the fluidized bed steam reformer. A determination of the adequacy of the fluidized bed steam reformer process to treat Hanford tank waste is required. The initial step in determining the adequacy of the fluidized bed steam reformer process is to select archived waste samples from the 222-S Laboratory that will be used in a bench scale tests. Analyses of the selected samples will be required to confirm the samples meet the shipping requirements and for comparison to the bench scale reformer (BSR) test sample selection requirements.

  19. Optimization of an Optical Test Bench for Tire Properties Measurement and Tread Defects Characterization

    Directory of Open Access Journals (Sweden)

    Juan Jesús Castillo Aguilar

    2017-03-01

    Full Text Available Tire characteristics and behavior are of great importance in vehicle dynamics since the forces transmitted in the tire-road contact are the main contributors to global vehicle performance. Several research groups have focused on the study and modeling of tires. Some of the most important factors that need to be known are tread characteristics and pressure distribution in the tire-ground contact patch. In this work, a test bench has been used to adequately determine the aforementioned factors. The measurement principle of the test bench is the frustration of total internal reflection (FTIR of light. It makes use of a laterally illuminated glass on which the tire leans. An interposed plastic interface between them causes the reflection of light. Finally, a video camera captures the bright image formed through the glass. The brightness level in each pixel of the image is related to existing normal pressure. A study of the parameters that affect the test bench calibration such as type of interface material used, diffuse light, hysteresis, creep and transverse light absorption is performed. Experimental tests are conducted to relate tire inflation pressure and camber angle to the pressure distribution. Furthermore, the test bench is used to detect and evaluate the influence of defects in the tire on the contact pressures.

  20. Principles of developing the bench mark net for radioecological monitoring in the territory of Byelorussia

    International Nuclear Information System (INIS)

    Doroshkevich, M.N.

    1991-01-01

    The principles of developing the radioecological monitoring bench mark net proposed include the regularity pattern of reference point setting, the bench mark net hierarchy, accounting for a land-tenure structure and the landscape and geochemical conditions of the radionuclide migration as well as a passport system and informational adequacy. The expression has been obtained for determining the location of sampling points

  1. Comparison of muscle force production using the Smith machine and free weights for bench press and squat exercises.

    Science.gov (United States)

    Cotterman, Michael L; Darby, Lynn A; Skelly, William A

    2005-02-01

    The Smith machine (SM) (vertical motion of bar on fixed path; fixed-form exercise) and free weights (FWs) (free-form path) are commonly used strength training modes. Exercisers may need to alternate between types of equipment, depending on testing, training, rehabilitation, and/or the exercisers' goals. The purposes of this study were to compare muscle force production for SM and FWs using a 1 repetition maximum (1RM) for the parallel back squat and supine bench press exercises and to predict the 1RM for one mode from 1RM on the other mode. Men (n = 16) and women (n = 16) alternately completed 1RM testing for squat and bench press using SM and FWs. Analyses of variance (type of equipment x sex) and linear regression models were calculated. A significant difference was found between bench press and squat 1RMs for each mode of equipment for all participants. The squat 1RM was greater for the SM than the FWs; conversely, the bench 1RM was greater for FWs than the SM. When sex was considered, bench 1RM for FWs was greater than SM for men and women. The squat 1RM was greater for SM than FWs for women only. The 1RM on one mode of equipment was the best predictor of 1RM for the other mode. For both sexes, the equation SM bench 1RM (in kilograms) = -6.76 + 0.95 (FW bench 1RM) can be used. For women only, SM squat 1RM (in kilograms) = 28.3 + 0.73 (FW squat 1RM). These findings provide equations for converting between SM and FW equipment for training.

  2. Wind Generators Test Bench. Optimal Design of PI Controller

    Directory of Open Access Journals (Sweden)

    TUDORACHE, T.

    2011-08-01

    Full Text Available This paper proposes a novel and robust strategy for the optimal design of the drive system integrated in a wind generators test bench. The PI regulator coefficients used in control systems are usually computed based on simplified hypotheses and then tuned manually so as the system response meet certain specifications in terms of stability, accuracy and speed. The proposed methodology permits the automatic identification of PI regulator coefficients using intelligent optimization algorithms, the initial guess for the search procedure being determined based on particular simplified hypotheses. The proposed procedure can help the design engineers to drastically reduce the effort for finding the best PI regulator coefficients offering a range of feasible solutions depending on the imposed optimum criteria. The characteristics and performances of the optimization strategy are highlighted by using it for the design of a DC motor drive system used to simulate the wind prime mover integrated in a wind generators test bench.

  3. Effect of an Unstable Load on Primary and Stabilizing Muscles During the Bench Press.

    Science.gov (United States)

    Ostrowski, Stephanie J; Carlson, Lara A; Lawrence, Michael A

    2017-02-01

    Ostrowski, SJ, Carlson, LA, and Lawrence, MA. Effect of an unstable load on primary and stabilizing muscles during the bench press. J Strength Cond Res 31(2): 430-434, 2017-Unstable resistance exercises are performed to increase activity of stabilizing muscles. The premise is that this increase in activity will yield greater strength gains than traditional resistance exercises. The purpose of this study was to determine if an unstable load increases muscle activity of stabilizing muscles during a bench press as compared with a standard bench press with a typical load. Fifteen resistance-trained males (age 24.2 ± 2.7 years, mass 84.8 ± 12.0 kg, height 1.77 ± 0.05 m, weight lifting experience 9.9 ± 3.4 years, and bench press 1 repetition maximum [1RM] 107.5 ± 25.9 kg) volunteered for this study. Subjects pressed 2 sets of 5 repetitions in both stable (75% 1RM) and unstable (60% 1RM) conditions using a standard barbell and a flexible Earthquake bar, respectively. Surface electromyography was used to detect muscle activity of primary movers (pectoralis major, anterior deltoid, and triceps) and stabilizing musculature (latissimus dorsi, middle and posterior deltoid, biceps brachii, and upper trapezius). Muscle activity was compared using a multivariate analysis of variance to determine significant (p ≤ 0.05) phase and condition differences. The right and left biceps and the left middle deltoid were significantly more active in the unstable condition. Some of the stabilizing muscles were found to be significantly more active in the unstable condition with 15% less weight. Therefore, bench pressing with an unstable load appears promising in activating stabilizing musculature compared with pressing a typical barbell.

  4. The development of a repetition-load scheme for the eccentric-only bench press exercise.

    Science.gov (United States)

    Moir, Gavin L; Erny, Kyle F; Davis, Shala E; Guers, John J; Witmer, Chad A

    2013-01-01

    The purpose of the present study was to develop a repetition-load scheme for the eccentric-only bench press exercise. Nine resistance trained men (age: 21.6 ± 1.0 years; 1-repetition maximum [RM] bench press: 137.7 ± 30.4 kg) attended four testing sessions during a four week period. During the first session each subject's 1-RM bench press load utilizing the stretch-shortening cycle was determined. During the remaining sessions they performed eccentric-only repetitions to failure using supra-maximal loads equivalent to 110%, 120% and 130% of their 1-RM value with a constant cadence (30 reps·min(-1)). Force plates and a three dimensional motion analysis system were used during these final three sessions in order to evaluate kinematic and kinetic variables. More repetitions were completed during the 110% 1-RM condition compared to the 130% 1-RM condition (p=0.01). Mean total work (p=0.046) as well as vertical force (p=0.049), vertical work (p=0.017), and vertical power output (p=0.05) were significantly greater during the 130% 1-RM condition compared to the 110% 1-RM condition. A linear function was fitted to the number of repetitions completed under each load condition that allowed the determination of the maximum number of repetitions that could be completed under other supra-maximal loads. This linear function predicted an eccentric-only 1-RM in the bench press with a load equivalent to 164.8% 1-RM, producing a load of 227.0 ± 50.0 kg. The repetition-load scheme presented here should provide a starting point for researchers to investigate the kinematic, kinetic and metabolic responses to eccentric-only bench press workouts.

  5. Design and construction of the HESR BPM prototype wire test bench at COSY, Forschungzentrum Juelich

    Energy Technology Data Exchange (ETDEWEB)

    Srinivasan, Sudharsan; Kamerdzhiev, Vsevolod; Boehme, Christian [Forschungszentrum Juelich GmbH (Germany)

    2016-07-01

    The Institute of Nuclear Physics 4(IKP-4), of the Research Center Juelich (FZJ), is in charge of building and commissioning the High Energy Storage Ring (HESR) within the international facility, Facility for Antiproton and Ion Research (FAIR) at Darmstadt. Beam Position Monitors (BPMs) are an essential instrument for any accelerator allowing operators to accurately monitor and control the accelerated beam. The demand for a BPM test bench will be showcased which will help to assess the design's ability to meet the system requirements. The weight is on the factors considered for the development of the initial test bench, its functional components, the metrology tests for ensuring positional measurement accuracy, and the design modifications from metrology investigations leading to the conceptual development of a new test bench.

  6. The bench scientist’s perspective on the unique considerations in nanoparticle regulation

    International Nuclear Information System (INIS)

    Marquis, Bryce J.; Maurer-Jones, Melissa A.; Ersin, Özlem H.; Lin, Yu-shen; Haynes, Christy L.

    2011-01-01

    The emergence and use of nanotechnologies in commercially available products, including nanotherapeutics, have necessitated the response of regulatory agencies to ensure that these products are safely employed. While bench scientists are at the forefront of nanoparticle development and design, many are unaware of the regulatory requirements necessary to transform their laboratory discoveries into marketable products. As bench scientists, we performed a “thought experiment” using multifunctional mesoporous silica nanoparticles synthesized in our lab, which we considered as a combination product, to try to understand the steps necessary for pre-clinical approval from the Food and Drug Administration. This thought experiment illuminated challenges associated with nanoparticle risk assessment and regulation.

  7. Treatment of Synthetic Wastewater Containing AB14 Pigment by Electrooxidation in both Pilot and Bench Scale Reactors

    Directory of Open Access Journals (Sweden)

    Jalal Basiri parsa

    2016-01-01

    Full Text Available The electrochemical oxidation process was used for the degradation of Acid Brown 14 in both bench and pilot scale reactors. The bench scale one with a working volume of 0.5 L was equipped with platinum plate used as the anode and stainless steel (SS-304 plates as the cathode. The pilot scale reactor had a volume of 9 L and was equipped with SS-304 plates used as both the anode and the cathode. Experiments were run using these reactors to investigate the two parameters of energy consumption and anode efficiency. The bench scale reactor was capable of removing 92% and 36% of the dye and COD, respectively, after 18 min of operation. The pilot scale reactor, however, was capable of removing 87% and 59% of the dye and the COD content, respectively, after 60 min of operation. The kinetic study of both the bench and pilot reactors for dye and COD removals showed that both processes followed a zero order kinetic.

  8. Comparison of electromyographic activity during the bench press and barbell pulloverexercises

    Directory of Open Access Journals (Sweden)

    Yuri de Almeida Costa Campos

    2014-06-01

    Full Text Available The aim of the study was to compare the electromyographic (EMG activity of the following muscles: clavicular portion of pectoralis major, sternal portion of pectoralis major, long portion of triceps brachii, anterior deltoid, posterior deltoid and latissimus dorsi during dynamic contractions between flat horizontal bench press and barbell pulloverexercises. The sample comprised 12 males individuals experienced in resistance training. The volunteers made three visits to the laboratory. The first one consisted of 12 repetitions of the exercises for the electromyographic data collection. The results showed a higher EMG activation of the pectoralis major and anterior deltoid muscles in the flat horizontal bench press in comparison with the barbell pullover. The triceps brachii and latissimus dorsi muscles were more activated in the barbell pullover.

  9. Design and Construction of a Test Bench to Characterize Efficiency and Reliability of High Voltage Battery Energy Storage Systems

    DEFF Research Database (Denmark)

    Blank, Tobias; Thomas, Stephan; Roggendorf, Christoph

    2010-01-01

    system efficiency. High voltage batteries may be advantageous for future medium voltage DC-grids as well. In all cases, high availability and reliability is indispensable. Investigations on the operating behavior of such systems are needed. For this purpose, a test bench for high voltage storage systems...... was built to analyze these processes for different battery technologies. A special safety infrastructure for the test bench was developed due to the high voltage and the storable energy of approximately 120 kWh. This paper presents the layout of the test bench for analyzing high voltage batteries with about...... 4,300 volts including all components, the safety requirements with the resultant safety circuit and the aim of the investigations to be performed with the test bench....

  10. DEGRADATION OF POLYNUCLEAR AROMATIC HYDROCARBONS UNDER BENCH-SCALE COMPOST CONDITIONS

    Science.gov (United States)

    The relationship between biomass growth and degradation of polynuclear aromatic hydrocarbons (PAHs) in soil, and subsequent toxicity reduction, was evaluated in 10 in-vessel, bench-scale compost units. Field soil was aquired from the Reilly Tar and Chemical Company Superfund site...

  11. Comparative Performance of Rear Facing Child Restraint Systems on the CMVSS 213 Bench and Vehicle Seats

    Science.gov (United States)

    Tylko, Suzanne; Locey, Caitlin M.; Garcia-Espana, J. Felipe; Arbogast, Kristy B.; Maltese, Matthew R.

    2013-01-01

    The purpose of this study was to compare the dynamic response of rear-facing child restraint systems (RFCRS) installed on the CMVSS 213 sled bench and a selection of vehicle seats. Thirty-six sled tests were conducted: three models of rear facing CRS with an anthropomorphic test device (ATD) representing a 12 month old child (CRABI) were affixed via lower anchors (LATCH), 3 point belt without CRS base, and 3 point belt with CRS base to one of three vehicle seats or the CMVSS 213 bench seat. All CRS were subjected to an identical sled acceleration pulse. Two types of matched pair analysis: “bench-to-vehicle” and “method of attachment” were conducted. Statistically significant differences were observed in the kinematic responses of the ATD and the CRS. This is the first study to quantify differences between the regulatory bench and vehicle seats on a system level and evaluate the influence of attachment method. Our results show that the difference in RFCRS forward excursion between 3-point belt with base and LATCH installations was between 1 and 7 percent on the bench and 22 to 76 percent on the vehicle seats. When evaluating the dynamic performance of RFCRS, the use of real vehicle seats from vehicles that commonly carry children may provide valuable insight. The findings would require further confirmation using a broader selection of RFCRS and vehicle seats, before generalizable conclusions can be drawn. PMID:24406967

  12. Bench-scale magnetic separation of Department of Energy wastes

    International Nuclear Information System (INIS)

    Hoegler, J.M.

    1987-07-01

    Criteria were developed for selection of candidate wastes for testing magnetic separation of uranium and/or other paramagnetic materials. A survey of Department of Energy (DOE) hazardous wastes was conducted to determine good candidates for bench-scale magnetic separation tests. Representatives of 21 DOE sites were contacted, and 11 materials were identified as potential candidates for magnetic separation. To date, seven samples have been obtained and tested for separability of uranium with a bench-scale magnetic assaying device. The samples tested have been obtained from the K-1401B and K-1401C ponds in Oak Ridge, Tennessee; from waste piles in Maywood, New Jersey; from North and South Ponds in Richland, Washington; and from magnesium fluoride drums in Fernald, Ohio. The magnetic device utilized in these tests can be used in an open-gradient mode with dry particulate or liquid-suspended materials. Uranium separation from magnesium fluoride has shown exceptionally good performance in both open- and high-gradient modes and could be an important application of the technology

  13. Optimization Of Blasting Design Parameters On Open Pit Bench A Case Study Of Nchanga Open Pits

    Directory of Open Access Journals (Sweden)

    Victor Mwango Bowa

    2015-08-01

    Full Text Available Abstract In hard rock mining blasting is the most productive excavation technique applied to fragment insitu rock to the required size for efficient loading and crushing. In order to blast the insitu rock to the desired fragment size blast design parameter such as bench height hole diameter spacing burden hole length bottom charge specific charge and rock factor are considered. The research was carried out as a practical method on Nchanga Open Pits NOP ore Bench to optimize the blasting design parameters that can yield the required fragmentation size thereby reducing the shovel loading times and maximizing efficiency of the subsequent mining unit operations such as hauling and crushing. Fragmentation characteristics such as the mean fragment size were measured by means of a digital measuring tape and predicated using the Kuznetsov equation and rock factor value of ore bench was calculated using Lilly 1986 equations by means of rock characteristics. Traditional blasting design parameters were acquired for NOP and modified using Langerfors and Sharma P.A approaches. Several blast operations were conducted using both traditional and modified blasting design parameters on the same ore bench with the same geological conditions. Loading times of the shovel and fragment sizes were obtained after the blasts from ore bench where both the traditional and modified blasting design parameters were applied. Results show that mean fragment size and loading times were reduced from 51cm and 12minutes to 22cm and 3minutes where traditional and modified blasting design parameters were applied respectively.

  14. Bench Blasting Design for Optimum Recovery of Blocks in ...

    African Journals Online (AJOL)

    In this research work, breaking factor is used in place of powder factor since breaking is required not powder. The aim of this research work is to establish a standard breaking factor for bench blasting in dimension quarries that will improve recovery. Two cases were considered. In case 1, gun powder is used for basal ...

  15. Comparison of the goals and MISTELS scores for the evaluation of surgeons on training benches.

    Science.gov (United States)

    Wolf, Rémi; Medici, Maud; Fiard, Gaëlle; Long, Jean-Alexandre; Moreau-Gaudry, Alexandre; Cinquin, Philippe; Voros, Sandrine

    2018-01-01

    Evaluation of surgical technical abilities is a major issue in minimally invasive surgery. Devices such as training benches offer specific scores to evaluate surgeons but cannot transfer in the operating room (OR). A contrario, several scores measure performance in the OR, but have not been evaluated on training benches. Our aim was to demonstrate that the GOALS score, which can effectively grade in the OR the abilities involved in laparoscopy, can be used for evaluation on a laparoscopic testbench (MISTELS). This could lead to training systems that can identify more precisely the skills that have been acquired or must still be worked on. 32 volunteers (surgeons, residents and medical students) performed the 5 tasks of the MISTELS training bench and were simultaneously video-recorded. Their performance was evaluated with the MISTELS score and with the GOALS score based on the review of the recording by two experienced, blinded laparoscopic surgeons. The concurrent validity of the GOALS score was assessed using Pearson and Spearman correlation coefficients with the MISTELS score. The construct validity of the GOALS score was assessed with k-means clustering and accuracy rates. Lastly, abilities explored by each MISTELS task were identified with multiple linear regression. GOALS and MISTELS scores are strongly correlated (Pearson correlation coefficient = 0.85 and Spearman correlation coefficient = 0.82 for the overall score). The GOALS score proves to be valid for construction for the tasks of the training bench, with a better accuracy rate between groups of level after k-means clustering, when compared to the original MISTELS score (accuracy rates, respectively, 0.75 and 0.56). GOALS score is well suited for the evaluation of the performance of surgeons of different levels during the completion of the tasks of the MISTELS training bench.

  16. T and D-Bench--Innovative Combined Support for Education and Research in Computer Architecture and Embedded Systems

    Science.gov (United States)

    Soares, S. N.; Wagner, F. R.

    2011-01-01

    Teaching and Design Workbench (T&D-Bench) is a framework aimed at education and research in the areas of computer architecture and embedded systems. It includes a set of features not found in other educational environments. This set of features is the result of an original combination of design requirements for T&D-Bench: that the…

  17. Development of training simulator based on critical assemblies test bench

    International Nuclear Information System (INIS)

    Narozhnyi, A.T.; Vorontsov, S.V.; Golubeva, O.A.; Dyudyaev, A.M.; Il'in, V.I.; Kuvshinov, M.I.; Panin, A.V.; Peshekhonov, D.P.

    2007-01-01

    When preparing critical mass experiment, multiplying system (MS) parts are assembled manually. This work is connected with maximum professional risk to personnel. Personnel training and keeping the skill of working experts is the important factor of nuclear safety maintenance. For this purpose authors develop a training simulator based on functioning critical assemblies test bench (CATB), allowing simulation of the MS assemblage using training mockups made of inert materials. The control program traces the current status of MS under simulation. A change in the assembly neutron physical parameters is mapped in readings of the regular devices. The simulator information support is provided by the computer database on physical characteristics of typical MS components The work in the training mode ensures complete simulation of real MS assemblage on the critical test bench. It makes it possible to elaborate the procedures related to CATB operation in a standard mode safely and effectively and simulate possible abnormal situations. (author)

  18. Developing of a software for determining advanced brake failures in brakes test bench

    Directory of Open Access Journals (Sweden)

    Hakan Köylü

    2016-08-01

    Full Text Available At present time, the brake test bench conducts the braking and suspension tests of front or rear axles and the test results are evaluated through one axle. The purpose of the brake testing system is to determine braking force and damping coefficient dissymmetry of one axle. Thus, this test system evaluates the performance of service brake, hand brake and suspension systems by considering separately front and rear axle dissymmetry. For this reason, the effects of different braking and damping forces applied by right and left wheels of both axles on braking performance of all vehicle are not determined due to available algorithm of the test bench. Also, the other brake failures are not occurred due to the algorithm of brake test system. In this study, the interface has been developed to determine the other effects of dissymmetry and the other brake failures by using the one axle results of brake test bench. The interface has algorithm computing the parameters according to the interaction between front and rear axles by only using measured test results. Also, it gives the warnings by comparing changes in the parameters with braking performance rules. Braking and suspension tests of three different vehicles have been conducted by using brake test bench to determine the performance of the algorithm. Parameters based on the axle interaction have been calculated by transferring brake test results to the interface and the test results have been evaluated. As a result, the effects of brake and suspension failures on braking performance of both axle and vehicle have been determined thanks to the developed interface.

  19. Experimental study on an IC engine in-cylinder flow using different steady-state flow benches

    Directory of Open Access Journals (Sweden)

    M. El-Adawy

    2017-12-01

    Full Text Available In-cylinder air flow structures are known to strongly impact on the performance and combustion of internal combustion engines (ICE. Therefore the aim of this paper is to experimentally study an IC engine in-cylinder flow under steady-state conditions. Different methods can be used to characterize the in-cylinder flow which are optical engines and laser diagnostics, computational fluid dynamic and steady-state flow bench. Here we are concentrating on two different types of flow benches. The first (Ricardo uses the impulse torque meter method while the other (FEV uses the paddle wheel technique. The experiments were carried out on the same cylinder head and the same pressure difference across the inlet valves of 600 mmH2O in order to compare the results. The experimental results are presented in terms of the measured air flow rate, flow coefficient, discharge coefficient and non-dimensional rig tumble. Moreover, number of modifications were conducted on the FEV flow bench in order to apply particle image velocimetry measurements on the vertical tumble plane, which passing through the middle of the cylinder at different valve lifts. The results show that a reasonably good level of agreement can be achieved between both methods, providing the methods of calculations of the various parameters are consistent. Keywords: In-cylinder flow, Flow bench, Tumble motion, Flow coefficient, Particle image velocimetry

  20. Effects of different vibration exercises on bench press.

    Science.gov (United States)

    Marín, P J; Torres-Luque, G; Hernández-García, R; García-López, D; Garatachea, N

    2011-10-01

    This study was undertaken to analyze the effects of different vibration recovery strategies via feet or hands on the number of repetitions performed and on mean velocity, peak velocity and blood lactate concentration during consecutive bench-press sets. 9 elite judo athletes performed 3 sets of bench press at 60% of one-repetition maximum (1RM), leading to failure and allowing a 180 s rest period between sets. During the rest period, 1 of the 3 following procedures was performed: 150 s rest plus 30 s push-up vibration exercise (Push-up), 150 s rest plus 30 s squat vibration exercise (Squat) or 180 s only rest (Passive). Statistical analysis revealed that the Squat condition resulted in a significant increase in the number of repetitions achieved, in comparison with all other rest strategies. However, kinematic parameters and blood lactate concentration were not affected by vibration. These data suggest that a vibration stimulus applied to the feet, between sets, can result in positive improvements in upper body resistance exercise performance. Although the mechanisms are not fully understood, this positive effect of vibration could be due to an increased motor cortex excitability and voluntary drive. © Georg Thieme Verlag KG Stuttgart · New York.

  1. High league bench players and starters: differences in group interactions, group cohesion, role acceptance and self-confidence in football teams

    OpenAIRE

    Simonenkova Irina Petrovna

    2015-01-01

    Main staff players differ from bench players in their perceptions and demonstrate different responses. This research compares the situation of bench players with the situation of starters in high league Latvian football teams.

  2. EMG analysis and modelling of flat bench press using artificial ...

    African Journals Online (AJOL)

    The objective of this study was to evaluate the contribution of particular muscle groups during the Flat Bench Press (FBP) with different external loads. Additionally, the authors attempted to determine whether regression models or Artificial Neural Networks (ANNs) can predict FBP results more precisely and whether they can ...

  3. Bidirectional converter interface for a battery energy storage test bench

    DEFF Research Database (Denmark)

    Trintis, Ionut; Thomas, Stephan; Blank, Tobias

    2011-01-01

    This paper presents the bidirectional converter interface for a 6 kV battery energy storage test bench. The power electronic interface consists a two stage converter topology having a low voltage dc-ac grid connected converter and a new dual active bridge dc-dc converter with high transformation...

  4. Design guidelines for high dimensional stability of CFRP optical bench

    Science.gov (United States)

    Desnoyers, Nichola; Boucher, Marc-André; Goyette, Philippe

    2013-09-01

    In carbon fiber reinforced plastic (CFRP) optomechanical structures, particularly when embodying reflective optics, angular stability is critical. Angular stability or warping stability is greatly affected by moisture absorption and thermal gradients. Unfortunately, it is impossible to achieve the perfect laminate and there will always be manufacturing errors in trying to reach a quasi-iso laminate. Some errors, such as those related to the angular position of each ply and the facesheet parallelism (for a bench) can be easily monitored in order to control the stability more adequately. This paper presents warping experiments and finite-element analyses (FEA) obtained from typical optomechanical sandwich structures. Experiments were done using a thermal vacuum chamber to cycle the structures from -40°C to 50°C. Moisture desorption tests were also performed for a number of specific configurations. The selected composite material for the study is the unidirectional prepreg from Tencate M55J/TC410. M55J is a high modulus fiber and TC410 is a new-generation cyanate ester designed for dimensionally stable optical benches. In the studied cases, the main contributors were found to be: the ply angular errors, laminate in-plane parallelism (between 0° ply direction of both facesheets), fiber volume fraction tolerance and joints. Final results show that some tested configurations demonstrated good warping stability. FEA and measurements are in good agreement despite the fact that some defects or fabrication errors remain unpredictable. Design guidelines to maximize the warping stability by taking into account the main dimensional stability contributors, the bench geometry and the optical mount interface are then proposed.

  5. Streamflow characteristics at hydrologic bench-mark stations

    Science.gov (United States)

    Lawrence, C.L.

    1987-01-01

    The Hydrologic Bench-Mark Network was established in the 1960's. Its objectives were to document the hydrologic characteristics of representative undeveloped watersheds nationwide and to provide a comparative base for studying the effects of man on the hydrologic environment. The network, which consists of 57 streamflow gaging stations and one lake-stage station in 39 States, is planned for permanent operation. This interim report describes streamflow characteristics at each bench-mark site and identifies time trends in annual streamflow that have occurred during the data-collection period. The streamflow characteristics presented for each streamflow station are (1) flood and low-flow frequencies, (2) flow duration, (3) annual mean flow, and (4) the serial correlation coefficient for annual mean discharge. In addition, Kendall's tau is computed as an indicator of time trend in annual discharges. The period of record for most stations was 13 to 17 years, although several stations had longer periods of record. The longest period was 65 years for Merced River near Yosemite, Calif. Records of flow at 6 of 57 streamflow sites in the network showed a statistically significant change in annual mean discharge over the period of record, based on computations of Kendall's tau. The values of Kendall's tau ranged from -0.533 to 0.648. An examination of climatological records showed that changes in precipitation were most likely the cause for the change in annual mean discharge.

  6. A Novel 100 kW Power Hardware-in-the-Loop Emulation Test Bench for Permanent Magnet Synchronous Machines with Nonlinear Magnetics

    OpenAIRE

    Schmitt, Alexander; Richter, Jan; Gommeringer, Mario; Wersal, Thomas; Braun, Michael

    2016-01-01

    This paper presents a high dynamic power hardware-inthe-loop (PHIL) emulation test bench to mimic arbitrary permanent magnet synchronous machines with nonlinear magnetics. The proposed PHIL test bench is composed of a high performance real-time simulation system to calculate the machine behaviour and a seven level modular multiphase multilevel converter to emulate the power flow of the virtual machine. The PHIL test bench is parametrized for an automotive synchronous machine and controlled by...

  7. A Comparison between Bench Press Throw and Ballistic Push-Up tests to assess upper-body power in trained individuals.

    Science.gov (United States)

    Bartolomei, Sandro; Nigro, Federico; Ruggeri, Sandro; Lanzoni, Ivan Malagoli; Ciacci, Simone; Merni, Franco; Sadres, Eliahu; Hoffman, Jay R; Semprini, Gabriele

    2018-03-06

    The purpose of the present study was to validate the ballistic push-up test performed with hands on a force plate (BPU) as a method to measure upper-body power. Twenty-eight experienced resistance trained men (age = 25.4 ± 5.2 y; body mass = 78.5 ± 9.0 kg; body height = 179.6 ± 7.8 cm) performed, two days apart, a bench press 1RM test and upper-body power tests. Mean power and peak power were assessed using the bench press throw test (BT) and the BPU test performed in randomized order. The area under the force/power curve (AUC) obtained at BT was also calculated. Power expressed at BPU was estimated using a time-based prediction equation. Mean force and the participant's body weight were used to predict the bench press 1RM. Pearson product moment correlations were used to examine relationships between the power assessment methods and between the predicted 1RM bench and the actual value. Large correlations (0.79; p bench and the 1RM predicted by the BPU. Results of the present study indicate that BPU represents a valid and reliable method to estimate the upper-body power in resistance-trained individuals.

  8. Simulation-based cutaneous surgical-skill training on a chicken-skin bench model in a medical undergraduate program.

    Science.gov (United States)

    Denadai, Rafael; Saad-Hossne, Rogério; Martinhão Souto, Luís Ricardo

    2013-05-01

    Because of ethical and medico-legal aspects involved in the training of cutaneous surgical skills on living patients, human cadavers and living animals, it is necessary the search for alternative and effective forms of training simulation. To propose and describe an alternative methodology for teaching and learning the principles of cutaneous surgery in a medical undergraduate program by using a chicken-skin bench model. One instructor for every four students, teaching materials on cutaneous surgical skills, chicken trunks, wings, or thighs, a rigid platform support, needled threads, needle holders, surgical blades with scalpel handles, rat-tooth tweezers, scissors, and marking pens were necessary for training simulation. A proposal for simulation-based training on incision, suture, biopsy, and on reconstruction techniques using a chicken-skin bench model distributed in several sessions and with increasing levels of difficultywas structured. Both feedback and objective evaluations always directed to individual students were also outlined. The teaching of a methodology for the principles of cutaneous surgery using a chicken-skin bench model versatile, portable, easy to assemble, and inexpensive is an alternative and complementary option to the armamentarium of methods based on other bench models described.

  9. A Comparative Study of Ground and Underground Vibrations Induced by Bench Blasting

    Directory of Open Access Journals (Sweden)

    Xiuzhi Shi

    2016-01-01

    Full Text Available Ground vibrations originating from bench blasting may cause damage to slopes, structures, and underground workings in close proximity to an operating open-pit mine. It is important to monitor and predict ground vibration levels induced by blasting and to take measures to reduce their hazardous effects. The aims of this paper are to determine the weaker protection objects by comparatively studying bench blasting induced vibrations obtained at surface and in an underground tunnel in an open-pit mine and thus to seek vibration control methods to protect engineering objects at the site. Vibrations arising from measurement devices at surface and in an underground tunnel at the Zijinshan Open-Pit Mine were obtained. Comparative analysis of the peak particle velocities shows that, in the greatest majority of cases, surface values are higher than underground values for the same vibration distance. The transmission laws of surface and underground vibrations were established depending on the type of rock mass, the explosive charge, and the distance. Compared with the Chinese Safety Regulations for Blasting (GB6722-2014, the bench blasting induced vibrations would not currently cause damage to the underground tunnel. According to the maximum allowable peak particle velocities for different objects, the permitted maximum charges per delay are obtained to reduce damage to these objects at different distances.

  10. The effect from maximal bench press strength training on work economy during wheelchair propulsion in men with spinal cord injury.

    Science.gov (United States)

    Tørhaug, T; Brurok, B; Hoff, J; Helgerud, J; Leivseth, G

    2016-10-01

    To assess the effect from maximal bench press strength training (MST) on wheelchair propulsion work economy (WE). Pretest-posttest case-control group design. St Olavs Hospital, Trondheim, Norway. Seventeen male individuals with spinal cord injury (SCI) paraplegia were allocated to either MST bench press (n=11) or the control group (CG) (n=7). The MST group trained bench press three times per week, for 6 weeks, starting at 85-95% of their pretest bench press one-repetition maximum (1RM). For calculation of WE during wheelchair propulsion, oxygen uptake (VO 2 ) measurements were collected during wheelchair ergometry (WCE) at submaximal workload of 50 W. Similarly, peak oxygen uptake (VO 2peak ) and peak power output (W) were measured during WCE. Individuals in the MST regimen significantly improved WE compared with the CG by 17.3 % (mean between-group differences: 95% confidence interval) of 2.63 ml kg -1  min -1 : (-4.34, -0.91) (P=0.007). Between pretest and posttest, the increase in bench press 1RM was by 17% higher in the MST group compared with the CG. At peak testing, the MST group generated significantly higher peak power compared with the CG. All other physiological variables were comparable within and between groups. A 6-week MST bench press regimen significantly improved WE during wheelchair propulsion at 50 W workload. These preliminary data support a possible beneficial role for MST to reduce the energy cost of wheelchair propulsion for SCI individuals.

  11. Test-retest reliability of barbell velocity during the free-weight bench-press exercise.

    Science.gov (United States)

    Stock, Matt S; Beck, Travis W; DeFreitas, Jason M; Dillon, Michael A

    2011-01-01

    The purpose of this study was to calculate test-retest reliability statistics for peak barbell velocity during the free-weight bench-press exercise for loads corresponding to 10-90% of the 1-repetition maximum (1RM). Twenty-one healthy, resistance-trained men (mean ± SD age = 23.5 ± 2.7 years; body mass = 90.5 ± 14.6 kg; 1RM bench press = 125.4 ± 18.4 kg) volunteered for this study. A minimum of 48 hours after a maximal strength testing and familiarization session, the subjects performed single repetitions of the free-weight bench-press exercise at each tenth percentile (10-90%) of the 1RM on 2 separate occasions. For each repetition, the subjects were instructed to press the barbell as rapidly as possible, and peak barbell velocity was measured with a Tendo Weightlifting Analyzer. The test-retest intraclass correlation coefficients (model 2,1) and corresponding standard errors of measurement (expressed as percentages of the mean barbell velocity values) were 0.717 (4.2%), 0.572 (5.0%), 0.805 (3.1%), 0.669 (4.7%), 0.790 (4.6%), 0.785 (4.8%), 0.811 (5.8%), 0.714 (10.3%), and 0.594 (12.6%) for the weights corresponding to 10-90% 1RM. There were no mean differences between the barbell velocity values from trials 1 and 2. These results indicated moderate to high test-retest reliability for barbell velocity from 10 to 70% 1RM but decreased consistency at 80 and 90% 1RM. When examining barbell velocity during the free-weight bench-press exercise, greater measurement error must be overcome at 80 and 90% 1RM to be confident that an observed change is meaningful.

  12. Muscle activation when performing the chest press and shoulder press on a stable bench vs. a Swiss ball.

    Science.gov (United States)

    Uribe, Brandon P; Coburn, Jared W; Brown, Lee E; Judelson, Daniel A; Khamoui, Andy V; Nguyen, Diamond

    2010-04-01

    The aim of this study was to examine the effects of a stable surface (bench) vs. an unstable surface (Swiss ball) on muscle activation when performing the dumbbell chest press and shoulder press. Sixteen healthy men (24.19 +/- 2.17 years) performed 1 repetition maximum (1RM) tests for the chest press and shoulder press on a stable surface. A minimum of 48 hours post 1RM, subjects returned to perform 3 consecutive repetitions each of the chest press and shoulder press at 80% 1RM under 4 different randomized conditions (chest press on bench, chest press on Swiss ball, shoulder press on bench, shoulder press on Swiss ball). Electromyography was used to assess muscle activation of the anterior deltoid, pectoralis major, and rectus abdominus. The results revealed no significant difference in muscle activation between surface types for either exercise. This suggests that using an unstable surface neither improves nor impairs muscle activation under the current conditions. Coaches and other practitioners can expect similar muscle activation when using a Swiss ball vs. a bench.

  13. Submicronic Particle Measurement Instrumentation Test Bench Data Acquisition and Control System

    International Nuclear Information System (INIS)

    Alberdi, J.; Barcala, J. M.; Sanz, D.; Gomez, F. J.; Molinero, A.; Navarrete, J. J.

    1999-01-01

    This document describes the SAD-100 system characteristics. The unit makes the instrumentation test bench data acquisition and control, SAD-100 was designed and developed by Electronic and Automation Area (CIEMAT) and Aerosol Technology in Energy Generation Project (CIEMAT). (Author) 2 refs

  14. Determination of bench-mark elevations at Bethel Island and vicinity, Contra Costa and San Joaquin counties, California, 1987

    Science.gov (United States)

    Blodgett, J.C.; Ikehara, M.E.; McCaffrey, William F.

    1988-01-01

    Elevations of 49 bench marks in the southwestern part of the Sacramento-San Joaquin River Delta were determined during October and November 1987. A total of 58 miles of level lines were run in the vicinity of Bethel Island and the community of Discovery Bay. The datum of these surveys is based on a National Geodetic Survey bench mark T934 situated on bedrock 10.5 mi east of Mount Diablo and near Marsh Creek Reservoir. The accuracy of these levels, based on National Geodetic Survey standards, was of first, second, and third order, depending on the various segments surveyed. Several bench marks were noted as possibly being stable, but most show evidence of instability. (USGS)

  15. Inter-subject variability of muscle synergies during bench press in power lifters and untrained individuals.

    Science.gov (United States)

    Kristiansen, M; Madeleine, P; Hansen, E A; Samani, A

    2015-02-01

    The purpose of the study was to elucidate the role of expertise on muscle synergies involved in bench press. Ten expert power lifters (EXP) and nine untrained participants (UNT) completed three sets of eight repetitions at 60% of three repetition maximum in bench press. Muscle synergies were extracted from surface electromyography data of 21 bench press cycles using non-negative matrix factorization algorithm. The synergy activation coefficient represents the relative contribution of the muscle synergy to the overall muscle activity pattern, while the muscle synergy vector represents the relative weighting of each muscle within each synergy. Describing more than 90% of the variability, two muscle synergies reflected the eccentric and concentric phase. The cross-correlations (ρ(max)) for synergy activation coefficient 2 (concentric phase) were 0.83 [0.71;0.88] and 0.59 [0.49;0.77] [Median ρ(max) (25th;75th percentile)] (P = 0.001) in UNT and EXP, respectively. Median correlation coefficient (ρ) for muscle synergy vector 2 was 0.15 [-0.08;0.46] and 0.48 [0.02;0.70] (P = 0.03) in UNT and EXP, respectively. Thus, EXP showed larger inter-subject variability than UNT in the synergy activation coefficient during the concentric phase, while the muscle synergy vectors were less variable in EXP. This points at the importance of a specialized neural strategy in elite bench press performance. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. Unknown loads affect force production capacity in early phases of bench press throws.

    Science.gov (United States)

    Hernández Davó, J L; Sabido Solana, R; Sarabia Marínm, J M; Sánchez Martos, Á; Moya Ramón, M

    2015-10-01

    Explosive strength training aims to improve force generation in early phases of movement due to its importance in sport performance. The present study examined the influence of lack of knowledge about the load lifted in explosive parameters during bench press throws. Thirteen healthy young men (22.8±2.0 years) participated in the study. Participants performed bench press throws with three different loads (30, 50 and 70% of 1 repetition maximum) in two different conditions (known and unknown loads). In unknown condition, loads were changed within sets in each repetition and participants did not know the load, whereas in known condition the load did not change within sets and participants had knowledge about the load lifted. Results of repeated-measures ANOVA revealed that unknown conditions involves higher power in the first 30, 50, 100 and 150 ms with the three loads, higher values of ratio of force development in those first instants, and differences in time to reach maximal rate of force development with 50 and 70% of 1 repetition maximum. This study showed that unknown conditions elicit higher values of explosive parameters in early phases of bench press throws, thereby this kind of methodology could be considered in explosive strength training.

  17. Inter- and intrasubject similarity of muscle synergies during bench press with slow and fast velocity

    DEFF Research Database (Denmark)

    Samani, Afshin; Kristiansen, Mathias

    2018-01-01

    We investigated the effect of low and high bar velocity on inter- and intra-subject similarity of muscle synergies during bench press. Thirteen trained male subjects underwent two exercise conditions, i.e. a slow and a fast velocity bench press. Surface electromyography was recorded from thirteen...... to describe the dataset variability. For the second activation coefficient, the inter-subject similarity within the fast velocity condition was greater than the intra-subject similarity of the activation coefficient across the conditions. An opposite pattern was observed for the first muscle synergy vector...

  18. ReaderBench goes Online: A Comprehension-Centered Framework for Educational Purposes

    NARCIS (Netherlands)

    Gutu, Gabriel; Dascalu, Mihai; Trausan-Matu, Stefan; Dessus, Philippe

    2016-01-01

    In this paper we introduce the online version of our ReaderBench framework, which includes multi-lingual comprehension-centered web services designed to address a wide range of individual and collaborative learning scenarios, as follows. First, students can be engaged in reading a course

  19. Research on Test-bench for Sonic Logging Tool

    Directory of Open Access Journals (Sweden)

    Xianping Liu

    2016-01-01

    Full Text Available In this paper, the test-bench for sonic logging tool is proposed and designed to realize automatic calibration and testing of the sonic logging tool. The test-bench System consists of Host Computer, Embedded Controlling Board, and functional boards. The Host Computer serves as the Human Machine Interface (HMI and processes uploaded data. The software running on Host Computer is designed on VC++, which is developed based on multithreading, Dynamic Linkable Library (DLL and Multiple Document Interface (MDI techniques. The Embedded Controlling Board uses ARM7 as the microcontroller and communicates with Host Computer via Ethernet. The Embedded Controlling Board software is realized based on embedded uclinux operating system with a layered architecture. The functional boards are designed based on Field Programmable Gate Array (FPGA and provide test interfaces for the logging tool. The functional board software is divided into independent sub-modules that can repeatedly be used by various functional boards and then integrated those sub-modules in the top layer. With the layered architecture and modularized design, the software system is highly reliable and extensible. With the help of designed system, a test has been conducted quickly and successfully on the electronic receiving cabin of the sonic logging tool. It demonstrated that the system could greatly improve the production efficiency of the sonic logging tool.

  20. Activation of selected shoulder muscles during unilateral wall and bench press tasks under submaximal isometric effort.

    Science.gov (United States)

    Tucci, Helga T; Ciol, Marcia A; de Araújo, Rodrigo C; de Andrade, Rodrigo; Martins, Jaqueline; McQuade, Kevin J; Oliveira, Anamaria S

    2011-07-01

    Controlled laboratory study. To assess the activation of 7 shoulder muscles under 2 closed kinetic chain (CKC) tasks for the upper extremity using submaximal isometric effort, thus providing relative quantification of muscular isometric effort for these muscles across the CKC exercises, which may be applied to rehabilitation protocols for individuals with shoulder weakness. CKC exercises favor joint congruence, reduce shear load, and promote joint dynamic stability. Additionally, knowledge about glenohumeral and periscapular muscle activity elicited during CKC exercises may help clinicians to design protocols for shoulder rehabilitation. Using surface electromyography, activation level was measured across 7 shoulder muscles in 20 healthy males, during the performance of a submaximal isometric wall press and bench press. Signals were normalized to the maximal voluntary isometric contraction, and, using paired t tests, data were analyzed between the exercises for each muscle. Compared to the wall press, the bench press elicited higher activity for most muscles, except for the upper trapezius. Levels of activity were usually low but were above 20% maximal voluntary isometric contraction for the serratus anterior on both tasks, and for the long head triceps brachii on the bench press. Both the bench press and wall press, as performed in this study, led to relatively low EMG activation levels for the muscles measured and may be considered for use in the early phases of rehabilitation.

  1. Correlating optical bench performance with clinical defocus curves in varifocal and trifocal intraocular lenses.

    Science.gov (United States)

    Plaza-Puche, Ana B; Alió, Jorge L; MacRae, Scott; Zheleznyak, Len; Sala, Esperanza; Yoon, Geunyoung

    2015-05-01

    To investigate the correlations existing between a trifocal intraocular lens (IOL) and a varifocal IOL using the "ex vivo" optical bench through-focus image quality analysis and the clinical visual performance in real patients by study of the defocus curves. This prospective, consecutive, nonrandomized, comparative study included a total of 64 eyes of 42 patients. Three groups of eyes were differentiated according to the IOL implanted: 22 eyes implanted with the varifocal Lentis Mplus LS-313 IOL (Oculentis GmbH, Berlin, Germany); 22 eyes implanted with the trifocal FineVision IOL (Physiol, Liege, Belgium), and 20 eyes implanted with the monofocal Acrysof SA60AT IOL (Alcon Laboratories, Inc., Fort Worth, TX). Visual outcomes and defocus curve were evaluated postoperatively. Optical bench through-focus performance was quantified by computing an image quality metric and the cross-correlation coefficient between an unaberrated reference image and captured retinal images from a model eye with a 3.0-mm artificial pupil. Statistically significant differences among defocus curves of different IOLs were detected for the levels of defocus from -4.00 to -1.00 diopters (D) (P < .01). Significant correlations were found between the optical bench image quality metric results and logMAR visual acuity scale in all groups (Lentis Mplus group: r = -0.97, P < .01; FineVision group: r = -0.82, P < .01; Acrys of group: r = -0.99, P < .01). Linear predicting models were obtained. Significant correlations were found between logMAR visual acuity and image quality metric for the multifocal and monofocal IOLs analyzed. This finding enables surgeons to predict visual outcomes from the optical bench analysis. Copyright 2015, SLACK Incorporated.

  2. The effect of recovery time on strength performance following a high-intensity bench press workout in males and females.

    Science.gov (United States)

    Judge, Lawrence W; Burke, Jeanmarie R

    2010-06-01

    To determine the effects of training sessions, involving high-resistance, low-repetition bench press exercise, on strength recovery patterns, as a function of gender and training background. The subjects were 12 athletes (6 males and 6 females) and age-matched college students of both genders (4 males and 4 females). The subjects completed a 3-wk resistance training program involving a bench press exercise, 3 d/wk, to become familiar with the testing procedure. After the completion of the resistance training program, the subjects, on three consecutive weeks, participated in two testing sessions per week, baseline session and recovery session. During the testing sessions, subjects performed five sets of the bench press exercise at 50% to 100% of perceived five repetition maximum (5-RM). Following the weekly baseline sessions, subjects rested during a 4-, 24-, or 48-h recovery period. Strength measurements were estimates of one repetition maximum (1-RM), using equivalent percentages for the number of repetitions completed by the subject at the perceived 5-RM effort of the bench press exercise. The full-factorial ANOVA model revealed a Gender by Recovery Period by Testing Session interaction effect, F(2, 32) = 10.65; P bench press exercises, using different recovery times of 48 h for males and 4 h for females may optimize strength development as a function of gender.

  3. Bench-Scale Development of a Non-Aqueous Solvent (NAS) CO2 Capture Process for Coal-Fired Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Lail, Marty

    2017-09-12

    The project aimed to advance RTI’s non-aqueous amine solvent technology by improving the solvent to reduce volatility, demonstrating long-term continuous operation at lab- (0.5 liters solvent) and bench-scale (~120 liters solvent), showing low reboiler heat duty measured during bench-scale testing, evaluating degradation products, building a rate-based process model, and evaluating the techno-economic performance of the process. The project team (RTI, SINTEF, Linde Engineering) and the technology performed well in each area of advancement. The modifications incorporated throughout the project enabled the attainment of target absorber and regenerator conditions for the process. Reboiler duties below 2,000 kJt/kg CO2 were observed in a bench-scale test unit operated at RTI.

  4. 41 CFR 109-27.5005 - Shop, bench, cupboard or site stock.

    Science.gov (United States)

    2010-07-01

    ... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false Shop, bench, cupboard or site stock. 109-27.5005 Section 109-27.5005 Public Contracts and Property Management Federal Property Management Regulations System (Continued) DEPARTMENT OF ENERGY PROPERTY MANAGEMENT REGULATIONS SUPPLY AND...

  5. An Electromyograph Comparison of an Isokenetic Bench Press at Three Speeds.

    Science.gov (United States)

    Ridgeway, M.; And Others

    The muscle action potentials (MAP) of the anterior deltoid, pectoralis major, biceps brachii, and the triceps muscle were studied by quantitative electromyography (emg) during a bench press exercise at three controlled speeds. Bipolar surface electrodes with standard placement were employed throughout the study. Eleven volunteer college women…

  6. Simulation-based cutaneous surgical-skill training on a chicken-skin bench model in a medical undergraduate program

    Directory of Open Access Journals (Sweden)

    Rafael Denadai

    2013-01-01

    Full Text Available Background: Because of ethical and medico-legal aspects involved in the training of cutaneous surgical skills on living patients, human cadavers and living animals, it is necessary the search for alternative and effective forms of training simulation. Aims: To propose and describe an alternative methodology for teaching and learning the principles of cutaneous surgery in a medical undergraduate program by using a chicken-skin bench model. Materials and Methods: One instructor for every four students, teaching materials on cutaneous surgical skills, chicken trunks, wings, or thighs, a rigid platform support, needled threads, needle holders, surgical blades with scalpel handles, rat-tooth tweezers, scissors, and marking pens were necessary for training simulation. Results: A proposal for simulation-based training on incision, suture, biopsy, and on reconstruction techniques using a chicken-skin bench model distributed in several sessions and with increasing levels of difficultywas structured. Both feedback and objective evaluations always directed to individual students were also outlined. Conclusion: The teaching of a methodology for the principles of cutaneous surgery using a chicken-skin bench model versatile, portable, easy to assemble, and inexpensive is an alternative and complementary option to the armamentarium of methods based on other bench models described.

  7. Design and fabrication of a glovebox for the Plasma Hearth Process radioactive bench-scale system

    International Nuclear Information System (INIS)

    Wahlquist, D.R.

    1996-01-01

    This paper presents some of the design considerations and fabrication techniques for building a glovebox for the Plasma Hearth Process (PHP) radioactive bench-scale system. The PHP radioactive bench-scale system uses a plasma torch to process a variety of radioactive materials into a final vitrified waste form. The processed waste will contain plutonium and trace amounts of other radioactive materials. The glovebox used in this system is located directly below the plasma chamber and is called the Hearth Handling Enclosure (HHE). The HHE is designed to maintain a confinement boundary between the processed waste and the operator. Operations that take place inside the HHE include raising and lowering the hearth using a hydraulic lift table, transporting the hearth within the HHE using an overhead monorail and hoist system, sampling and disassembly of the processed waste and hearth, weighing the hearth, rebuilding a hearth, and sampling HEPA filters. The PHP radioactive bench-scale system is located at the TREAT facility at Argonne National Laboratory-West in Idaho Falls, Idaho

  8. Embedded Sensors and Controls to Improve Component Performance and Reliability -- Bench-scale Testbed Design Report

    Energy Technology Data Exchange (ETDEWEB)

    Melin, Alexander M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Kisner, Roger A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Drira, Anis [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Reed, Frederick K. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-09-01

    Embedded instrumentation and control systems that can operate in extreme environments are challenging due to restrictions on sensors and materials. As a part of the Department of Energy's Nuclear Energy Enabling Technology cross-cutting technology development programs Advanced Sensors and Instrumentation topic, this report details the design of a bench-scale embedded instrumentation and control testbed. The design goal of the bench-scale testbed is to build a re-configurable system that can rapidly deploy and test advanced control algorithms in a hardware in the loop setup. The bench-scale testbed will be designed as a fluid pump analog that uses active magnetic bearings to support the shaft. The testbed represents an application that would improve the efficiency and performance of high temperature (700 C) pumps for liquid salt reactors that operate in an extreme environment and provide many engineering challenges that can be overcome with embedded instrumentation and control. This report will give details of the mechanical design, electromagnetic design, geometry optimization, power electronics design, and initial control system design.

  9. Simulation of the LHC injection kicker impedance test bench

    CERN Document Server

    Tsutsui, H

    2003-01-01

    The coupling impedance measurements of the LHC injection kicker test bench are simulated by HFSS code. The simulation gives qualitatively good agreement with the measurement. In order to damp the resonances, some ferrite rings are tested in the simulation. Longitudinal resonances are damped by a ferrite ring of large tan$\\delta_{\\mu}$. The effect of the ferrite ring is small for damping the transverse impedance resonance around 30 MHz.

  10. How Adequate is your CV? Analyzing French CVs with ReaderBench

    NARCIS (Netherlands)

    Gutu, Gabriel; Dascalu, Mihai; Trausan-Matu, Stefan; Lepoivre, Olivier

    2017-01-01

    This study is aimed at presenting a new ReaderBench-based tool built to support candidates in increasing the quality of their CV for a job opening. Both the visual quality and the textual content are considered while also providing an overview and corresponding feedback for the entire CV.

  11. Muscle synergies during bench press are reliable across days.

    Science.gov (United States)

    Kristiansen, Mathias; Samani, Afshin; Madeleine, Pascal; Hansen, Ernst Albin

    2016-10-01

    Muscle synergies have been investigated during different types of human movement using nonnegative matrix factorization. However, there are not any reports available on the reliability of the method. To evaluate between-day reliability, 21 subjects performed bench press, in two test sessions separated by approximately 7days. The movement consisted of 3 sets of 8 repetitions at 60% of the three repetition maximum in bench press. Muscle synergies were extracted from electromyography data of 13 muscles, using nonnegative matrix factorization. To evaluate between-day reliability, we performed a cross-correlation analysis and a cross-validation analysis, in which the synergy components extracted in the first test session were recomputed, using the fixed synergy components from the second test session. Two muscle synergies accounted for >90% of the total variance, and reflected the concentric and eccentric phase, respectively. The cross-correlation values were strong to very strong (r-values between 0.58 and 0.89), while the cross-validation values ranged from substantial to almost perfect (ICC3, 1 values between 0.70 and 0.95). The present findings revealed that the same general structure of the muscle synergies was present across days and the extraction of muscle synergies is thus deemed reliable. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Innovative lightweight substrate for stable optical benches and mirrors

    Science.gov (United States)

    Rugi Grond, E.; Herren, A.; Mérillat, S.; Fermé, J. J.

    2017-11-01

    High precision space optics, such as spectrometers, relay optics, and filters, require ultra stable, lightweight platforms. These equipped platforms have on one side to survive the launch loads, on the other side they have to maintain their stability also under the varying thermal loads occurring in space. Typically such platforms have their equipment (prisms, etalons, beam expanders, etc.) mounted by means of classical bonding, hydro-catalytic bonding or optical contacting. Therefore such an optical bench requires to provide an excellent flatness, minimal roughness and is usually made of the same material as the equipment it carries (glass, glass ceramics). For space systems, mass is a big penalty, therefore such optical platforms are in most cases light weighted by means of machining features (i.e. pockets). Besides of being not extremely mass efficient, such pockets reduce the load carrying capability of the base material significantly. The challenge for Oerlikon Space, in this context, was to develop, qualify and deliver such optical benches, providing a substantial mass reduction compared to actual light weighted systems, while maintaining most of the full load carrying capacity of the base material. Additionally such a substrate can find an attractive application for mirror substrates. The results of the first development and of the first test results will be presented.

  13. The National Football League-225 Bench Press Test and the Size-Weight Illusion.

    Science.gov (United States)

    Luebbers, Paul E; Buckingham, Gavin; Butler, Michael S

    2017-06-01

    The purpose of this study was to test reports that size and arrangement manipulations of weight plates (i.e., inducing a size-weight illusion [SWI]) effect athletic weightlifting performance. The participants were 72 experienced, weight-trained collegiate American football players. Across three weeks, each athlete performed three different repetitions-to-fatigue bench press tests (NFL-225, SWI-225, and SWI-215). A multiple regression revealed a positive association between participants' strength relative to the test load and repetitions for NFL-225 and SWI-215, but no association with SWI-225. To explore these results, players were ranked into quartiles based on their one-repetition maximum relative to 102.27 kg (225 lb), and a 3 × 4 repeated measures analysis of variance was conducted. The primary finding was a significant Test Condition × Quartile interaction ( p = .004). Bonferroni-corrected pairwise comparisons revealed that Quartile 4 (those with lowest strength relative to test load) completed more repetitions for SWI-225 compared with NFL-225 ( p = .049). These results suggest that alternate weight plate arrangements may be beneficial for those whose bench press load is near the lifter's one-repetition maximum. However, variations of the SWI do not appear to affect the performance of repetitions-to-fatigue bench press tests for the majority of collegiate American football players.

  14. Influence of ballistic bench press on upper body power output in professional rugby players.

    Science.gov (United States)

    West, Daniel J; Cunningham, Daniel J; Crewther, Blair T; Cook, Christian J; Kilduff, Liam P

    2013-08-01

    The use of heavy resistance exercise provides an effective preload stimulus for inducing postactivation potentiation (PAP) and increasing peak power output (PPO). However, this approach has limited application in many sporting situations (e.g., incorporation in a precompetition warm-up); and therefore, more practical strategies for inducing PAP need to be investigated. The aim of the present study was to compare the PPO changes after performing a preload stimulus of either a ballistic exercise or a traditional heavy resistance exercise. Twenty professional rugby union players completed 3 testing sessions, each separated by 48 hours. On the first occasion, subjects underwent a 3 repetition maximum (3RM)-bench press testing session. On the next 2 occasions, subjects performed a ballistic bench throw at baseline (30% of 1RM), followed by a preload stimulus of either heavy resistance training (HRT) (heavy bench press: 3 sets of 3 repetitions at 87% 1RM) or BBP (3 sets of 3 repetitions at 30% on 1RM) followed by ballistic bench throw after 8 minutes recovery. The trials were randomized and counterbalanced. Both preload stimuli protocols increased PPO compared with baseline (BBP baseline 892 ± 108 vs. 8 minutes 924 ± 119 W, p < 0.001; HRT baseline 893 ± 104 vs. 8 minutes 931 ± 116 W; p < 0.001). There were no conditional differences between PPO at 8 minutes (p = 0.141); moreover, the change in PPO from baseline was also similar between conditions (BBP Δ + 33 ± 18; HRT Δ + 38 ± 21 W; p = 0.112). In conclusion, a ballistic exercise provided an effective method of inducing PAP and increasing upper-body PPO; moreover, this elicited similar increases in PPO as a traditional heavy resistance exercise preloading stimulus.

  15. Bench press and push-up at comparable levels of muscle activity results in similar strength gains.

    Science.gov (United States)

    Calatayud, Joaquin; Borreani, Sebastien; Colado, Juan C; Martin, Fernando; Tella, Victor; Andersen, Lars L

    2015-01-01

    Electromyography (EMG) exercise evaluation is commonly used to measure the intensity of muscle contraction. Although researchers assume that biomechanically comparable resistance exercises with similar high EMG levels will produce similar strength gains over the long term, no studies have actually corroborated this hypothesis. This study evaluated EMG levels during 6 repetition maximum (6RM) bench press and push-up, and subsequently performed a 5-week training period where subjects were randomly divided into 3 groups (i.e., 6RM bench press group, 6RM elastic band push-up group, or control group) to evaluate muscle strength gains. Thirty university students with advanced resistance training experience participated in the 2-part study. During the training period, exercises were performed using the same loads and variables that were used during the EMG data collection. At baseline, EMG amplitude showed no significant difference between 6RM bench press and band push-up. Significant differences among the groups were found for percent change (Δ) between pretest and posttest for 6RM (p = 0.017) and for 1 repetition maximum (1RM) (p bench press group and 6RM elastic band push-up group improved their 1RM and 6RM (Δ ranging from 13.65 to 22.21) tests significantly with similar gains, whereas control group remains unchanged. Thus, when the EMG values are comparable and the same conditions are reproduced, the aforementioned exercises can provide similar muscle strength gains.

  16. ComprehensiveBench: a Benchmark for the Extensive Evaluation of Global Scheduling Algorithms

    Science.gov (United States)

    Pilla, Laércio L.; Bozzetti, Tiago C.; Castro, Márcio; Navaux, Philippe O. A.; Méhaut, Jean-François

    2015-10-01

    Parallel applications that present tasks with imbalanced loads or complex communication behavior usually do not exploit the underlying resources of parallel platforms to their full potential. In order to mitigate this issue, global scheduling algorithms are employed. As finding the optimal task distribution is an NP-Hard problem, identifying the most suitable algorithm for a specific scenario and comparing algorithms are not trivial tasks. In this context, this paper presents ComprehensiveBench, a benchmark for global scheduling algorithms that enables the variation of a vast range of parameters that affect performance. ComprehensiveBench can be used to assist in the development and evaluation of new scheduling algorithms, to help choose a specific algorithm for an arbitrary application, to emulate other applications, and to enable statistical tests. We illustrate its use in this paper with an evaluation of Charm++ periodic load balancers that stresses their characteristics.

  17. Analysis of Muscle Activity Utilizing Bench Presses in the AnyBody Simulation Modelling System

    Directory of Open Access Journals (Sweden)

    Zhongqiu Ji

    2016-01-01

    Full Text Available Using the AnyBody human modeling system with identical weights and varying grip distance (40.0 cm, 50.0 cm, and 60.0 cm, the stress distribution for the pectoralis and the muscle of upper extremity during a bench press was simulated, and the surface myoelectricity (EMG method was validated. Methods. The physical parameters driving the model of the human body were selected as weights of 35.0% (25.0 kg and grip distances. Conclusion. The validation of AnyBody software was proved as a high validity by using EMG test of four muscles’ activity compared to AnyBody software. During a bench press, the pectoralis major is the main muscle, the pectoralis major discharge increases with the height of barbell increases, and the pectoralis major discharge decreases as the short grip width increases. When the grip width equals the shoulder width, the value of pectoralis minor is lowest; when the grip width is smaller or larger than the shoulder width, the value is larger. As the short grip distance increases, the discharge of posterior deltoid muscle and triceps surface myoelectricity increases; thus, as the short grip distance increases, the deltoid muscle and triceps assist the pectoralis major during a bench press.

  18. Bench scale studies: Ozonation as a potential treatment for waters contaminated with hydrocarbons or dioxins and furans

    International Nuclear Information System (INIS)

    Schaal, W.

    1995-01-01

    The objective of the bench scale studies was to examine the destruction efficiency and efficacy of ozone on chemicals of concern (COC's) commonly found in contaminated ground water and rhenoformer wash water. The ground water used in these tests contained aromatic petroleum hydrocarbons, chlorinated hydrocarbons, and mineral spirits. The rhenoformer wash water used in these tests contained a variety of dioxins (including 2,3,7,8-tetrachlorodibenzo-p-dioxin) and furans. Summaries are presented of the bench scale studies by describing the COCs, methodologies, test reactors, observations, and results. The summaries also detail which applications hold promise with respect to ozonation and which ones do not. Bench test results for the experiments in which aromatic petroleum hydrocarbons, chlorinated hydrocarbons, and mineral spirits where the COCs were relatively successful. Concentrations for the COCs ranging from 300 to 3,400 micrograms per liter (microg/L) were brought below levels specified for storm sewer discharge per the National Priority Discharge Elimination Systems (NPDES) permit requirements. Bench test results for the experiments in which dioxins and furans were the COCs were less promising and revealed that additional processes would have to be used in conjunction with ozonation to bring the concentration of COCs within the targeted ranges. It was realized, however, that the effectiveness and efficacy of ozonation were diminished by the presence of particulates, to which some of the dioxin and furan compounds adhered

  19. The influence of isometric preload on power expressed during bench press in strength-trained men.

    Science.gov (United States)

    Bartolomei, Sandro; Fukuda, David H; Hoffman, Jay R; Stout, Jeffrey R; Merni, Franco

    2017-03-01

    The purpose of this study was to compare the power expressed during the bench press exercise in resistance-trained men following different pre-activation conditions. Twenty-two trained men (age 24.1 ± 1.7 years, height 178.6 ± 6.1 cm, body mass 81.1 ± 10.6 kg) completed a maximal effort bench press (1-RM) test (100.0 kg ± 8.1 kg). In a subsequent assessment, each participant performed concentric bench press movements with loads of 20%, 30%, 40% and 50% of their 1-RM preceded by either a concentric contraction (CC), a low isometric preload (LIP; 70% 1-RM) or a high isometric preload (HIP; 100% 1-RM) conditions. All movements were performed in a Smith machine with a settable quick-release device. Participants performed all three conditions in randomized fashion. Results indicated that power outputs during the bench press exercise following HIP were significantly (p < 0.05) greater than CC at 20% 1-RM (+9%), 30% 1-RM (+16%) and 40% 1-RM (+14%), and LIP at 20% 1-RM (+4%), 30% 1-RM (+20%) and 40% 1-RM (+15%). No differences were found between conditions at 50% 1-RM. Area under the force-power curve with HIP was greater (p < 0.05) than with CC and LIP. In conclusion, results of this study indicate that the use of a HIP (100% 1-RM) in trained participants results in significantly greater power output during the concentric phase of a multi-joint exercise when compared to standard concentric movement.

  20. Relationships among peak power output, peak bar velocity, and mechanomyographic amplitude during the free-weight bench press exercise.

    Science.gov (United States)

    Stock, Matt S; Beck, Travis W; Defreitas, Jason M; Dillon, Michael A

    2010-10-01

    The purpose of this study was to examine the relationships among mechanomyographic (MMG) amplitude, power output, and bar velocity during the free-weight bench press exercise. Twenty-one resistance-trained men [one-repetition maximum (1-RM) bench press = 125.4+18.4 kg] performed bench press muscle actions as explosively as possible from 10% to 90% of the 1-RM while peak power output and peak bar velocity were assessed with a TENDO Weightlifting Analyzer. During each muscle action, surface MMG signals were detected from the right and left pectoralis major and triceps brachii, and the concentric portion of the range of motion was selected for analysis. Results indicated that power output increased from 10% to 50% 1-RM, followed by decreases from 50% to 90% 1-RM, but MMG amplitude for each of the muscles increased from 10 to 80% 1-RM. The results of this study indicate that during the free-weight bench press exercise, MMG amplitude was not related to power output, but was inversely related to bar velocity and directly related to the external load being lifted. In future research, coaches and sport scientists may be able to estimate force/torque production from individual muscles during multi-joint, dynamic constant external resistance muscle actions.

  1. Interferometric 30 m bench for calibrations of 1D scales and optical distance measuring instruments

    International Nuclear Information System (INIS)

    Unkuri, J; Rantanen, A; Manninen, J; Esala, V-P; Lassila, A

    2012-01-01

    During construction of a new metrology building for MIKES, a 30 m interferometric bench was designed. The objective was to implement a straight, stable, adjustable and multifunctional 30 m measuring bench for calibrations. Special attention was paid to eliminating the effects of thermal expansion and inevitable concrete shrinkage. The linear guide, situated on top of a monolithic concrete beam, comprises two parallel round shafts with adjustable fixtures every 1 m. A carriage is moved along the rail and its position is followed by a reference interferometer. Depending on the measurement task, one or two retro-reflectors are fixed on the carriage. A microscope with a CCD camera and a monitor can be used to detect line mark positions on different line standards. When calibrating optical distance measuring instruments, various targets can be fixed to the carriage. For the most accurate measurements an online Abbe-error correction based on simultaneous carriage pitch measurement by a separate laser interferometer is applied. The bench is used for calibrations of machinist scales, tapes, circometers, electronic distance meters, total stations and laser trackers. The estimated expanded uncertainty for 30 m displacement for highest accuracy calibrations is 2.6 µm. (paper)

  2. arXiv Bench Measurements and Simulations of Beam Coupling Impedance

    CERN Document Server

    Niedermayer, Uwe

    After a general introduction, the basic principles of wake-field and beamcoupling- impedance computations are explained. This includes time domain, frequency domain, and methods that do not include excitations by means of a particle beam. The second part of this paper deals with radio frequency bench measurements of beam coupling impedances. The general procedure of the wire measurement is explained, and its features and limitations are discussed.

  3. Colonization of spoil benches of an opencast lignite mine in northwest Spain by amphibians and reptiles

    Energy Technology Data Exchange (ETDEWEB)

    Galan, P. [University of Santiago de Compostela, Santiago de Compostela (Spain). Faculty of Biology

    1997-02-01

    This paper discusses the colonization by reptiles and amphibians of the spoil benches of the Meirama opencast lignite mine in northwest Spain over 10 years, following the start of the revegetation process. At Meirama, spoil benches are initially fertilized and hydroseeded with a pasture mix, but are subject to little subsequent management and are gradually colonized by scrub vegetation characteristic of the region. Herpetofauna censuses were carried out yearly on a single 2 ha plot over 6 years following hydroseeding, and in a single year on ten 2 ha plots which had been hydroseeded between 0 and 10 years previously. In addition, censuses were carried out on three undisturbed `control` plots close to the mine. Fifteen species (nine amphibians and six reptiles) were detected in one or more of the spoil-bench plots. Recolonization was particularly rapid after the first 2-3 years post-hydroseeding, and was closely related to habitat development due to revegetation and natural succession. Species composition was most similar to that in control plots in the oldest (ten-year-old) spoil plots.

  4. Design of a Test Bench for Intraocular Lens Optical Characterization

    Energy Technology Data Exchange (ETDEWEB)

    Alba-Bueno, Francisco; Vega, Fidel; Millan, Maria S, E-mail: francisco.alba-bueno@upc.edu, E-mail: fvega@oo.upc.edu, E-mail: millan@oo.upc.edu [Departamento de Optica y Optometria, Universidad Politecnica de Cataluna, C/ Violinista Vellsola 37, 08222 Terrassa (Spain)

    2011-01-01

    The crystalline lens is the responsible for focusing at different distances (accommodation) in the human eye. This organ grows throughout life increasing in size and rigidity. Moreover, due this growth it loses transparency through life, and becomes gradually opacified causing what is known as cataracts. Cataract is the most common cause of visual loss in the world. At present, this visual loss is recoverable by surgery in which the opacified lens is destroyed (phacoemulsification) and replaced by the implantation of an intraocular lens (IOL). If the IOL implanted is mono-focal the patient loses its natural capacity of accommodation, and as a consequence they would depend on an external optic correction to focus at different distances. In order to avoid this dependency, multifocal IOLs designs have been developed. The multi-focality can be achieved by using either, a refractive surface with different radii of curvature (refractive IOLs) or incorporating a diffractive surface (diffractive IOLs). To analyze the optical quality of IOLs it is necessary to test them in an optical bench that agrees with the ISO119679-2 1999 standard (Ophthalmic implants. Intraocular lenses. Part 2. Optical Properties and Test Methods). In addition to analyze the IOLs according to the ISO standard, we have designed an optical bench that allows us to simulate the conditions of a real human eye. To do that, we will use artificial corneas with different amounts of optical aberrations and several illumination sources with different spectral distributions. Moreover, the design of the test bench includes the possibility of testing the IOLs under off-axis conditions as well as in the presence of decentration and/or tilt. Finally, the optical imaging quality of the IOLs is assessed by using common metrics like the Modulation Transfer Function (MTF), the Point Spread Function (PSF) and/or the Strehl ratio (SR), or via registration of the IOL's wavefront with a Hartmann-Shack sensor and its

  5. Catalytic multi-stage liquefaction of coal at HTI: Bench-scale studies in coal/waste plastics coprocessing

    Energy Technology Data Exchange (ETDEWEB)

    Pradhan, V.R.; Lee, L.K.; Stalzer, R.H. [Hydrocarbon Technologies, Inc., Lawrenceville, NJ (United States)] [and others

    1995-12-31

    The development of Catalytic Multi-Stage Liquefaction (CMSL) at HTI has focused on both bituminous and sub-bituminous coals using laboratory, bench and PDU scale operations. The crude oil equivalent cost of liquid fuels from coal has been curtailed to about $30 per barrel, thus achieving over 30% reduction in the price that was evaluated for the liquefaction technologies demonstrated in the late seventies and early eighties. Contrary to the common belief, the new generation of catalytic multistage coal liquefaction process is environmentally very benign and can produce clean, premium distillates with a very low (<10ppm) heteroatoms content. The HTI Staff has been involved over the years in process development and has made significant improvements in the CMSL processing of coals. A 24 month program (extended to September 30, 1995) to study novel concepts, using a continuous bench scale Catalytic Multi-Stage unit (30kg coal/day), has been initiated since December, 1992. This program consists of ten bench-scale operations supported by Laboratory Studies, Modelling, Process Simulation and Economic Assessments. The Catalytic Multi-Stage Liquefaction is a continuation of the second generation yields using a low/high temperature approach. This paper covers work performed between October 1994- August 1995, especially results obtained from the microautoclave support activities and the bench-scale operations for runs CMSL-08 and CMSL-09, during which, coal and the plastic components for municipal solid wastes (MSW) such as high density polyethylene (HDPE)m, polypropylene (PP), polystyrene (PS), and polythylene terphthlate (PET) were coprocessed.

  6. Validity of a Commercial Linear Encoder to Estimate Bench Press 1 RM from the Force-Velocity Relationship

    OpenAIRE

    Bosquet, Laurent; Porta-Benache, Jeremy; Blais, Jérôme

    2010-01-01

    The aim of this study was to assess the validity and accuracy of a commercial linear encoder (Musclelab, Ergotest, Norway) to estimate Bench press 1 repetition maximum (1RM) from the force - velocity relationship. Twenty seven physical education students and teachers (5 women and 22 men) with a heterogeneous history of strength training participated in this study. They performed a 1 RM test and a force - velocity test using a Bench press lifting task in a random order. Mean 1 RM was 61.8 ± 15...

  7. Qualification of an out-of-pile Thermohydraulic test Bench (BETHY) developed to calibrate calorimetric cells under specific JHR experimental conditions

    International Nuclear Information System (INIS)

    De Vita, C.; Brun, J.; Carette, M.; Reynard-Carette, C.; Lyoussi, A.; Fourmentel, D.; Villard, J.F.; Guimbal, P.; Malo, J.Y.

    2013-06-01

    Online in-pile measurement methods are crucial during irradiations in material testing reactors to better understand the behavior of materials under accelerated ageing conditions and of nuclear fuels under high irradiation levels. Thus, the construction of a new Material Testing Reactor such as the Jules Horowitz Reactor (JHR) leads to new research and development programs devoted to innovative instrumentation and measurement methods. The presented works are performed in the framework of the IN-CORE program, 'Instrumentation for Nuclear radiations and Calorimetry Online in Reactor', between CEA and Aix-Marseille University. The program aim is to develop experimental devices and test bench to quantify more precisely the nuclear heating parameter in the JHR experimental channels. This in-pile parameter is usually measured by means of calorimeter or gamma thermometer. This paper focuses on a new out-of-pile test bench called BETHY. This bench was developed to study the response of a differential calorimeter during its preliminary calibration step according to specific thermal and hydraulic conditions occurring inside one type of JHR core channel. The first section of this paper is dedicated to a detailed description of the bench. The second part presents the study of the thermal characteristics established in the bench for two main thermal running modes. The last one concerns the calibration curve of the reference cell of the differential calorimeter in the case of homogenous temperature. (authors)

  8. Effects of bench step exercise intervention on work ability in terms of cardiovascular risk factors and oxidative stress: a randomized controlled study.

    Science.gov (United States)

    Ohta, Masanori; Eguchi, Yasumasa; Inoue, Tomohiro; Honda, Toru; Morita, Yusaku; Konno, Yoshimasa; Yamato, Hiroshi; Kumashiro, Masaharu

    2015-01-01

    Work ability is partly determined by physical and mental fitness. Bench step exercise can be practiced anywhere at any time. The aim of this study was to determine the effects of a bench step exercise on work ability by examining cardiovascular risk factors and oxidative stress. Thirteen volunteers working in a warehousing industry comprised the bench step exercise group (n=7) and the control group (n=6). The participants in the step exercise group were encouraged to practice the step exercise at home for 16 weeks. The step exercise improved glucose metabolism and antioxidative capacity and increased work ability by reducing absences from work and improving the prognosis of work ability. The improvement in work ability was related to a reduction in oxidative stress. These results suggest that a bench step exercise may improve work ability by reducing cardiovascular risk factors and oxidative stress.

  9. Interset stretching does not influence the kinematic profile of consecutive bench-press sets.

    Science.gov (United States)

    García-López, David; Izquierdo, Mikel; Rodríguez, Sergio; González-Calvo, Gustavo; Sainz, Nuria; Abadía, Olaia; Herrero, Azael J

    2010-05-01

    This study was undertaken to examine the role of interset stretching on the time course of acceleration portion AP and mean velocity profile during the concentric phase of 2 bench-press sets with a submaximal load (60% of the 1 repetition maximum). Twenty-five college students carried out, in 3 different days, 2 consecutive bench-press sets leading to failure, performing between sets static stretching, ballistic stretching, or no stretching. Acceleration portion and lifting velocity patterns of the concentric phase were not altered during the second set, regardless of the stretching treatment performed. However, when velocity was expressed in absolute terms, static stretching reduced significantly (p velocity during the second set compared to the first one. Therefore, if maintenance of a high absolute velocity over consecutive sets is important for training-related adaptations, static stretching should be avoided or replaced by ballistic stretching.

  10. The HSOB GAIA: a cryogenic high stability cesic optical bench for missions requiring sub-nanometric optical stability

    Science.gov (United States)

    Courteau, Pascal; Poupinet, Anne; Kroedel, Mathias; Sarri, Giuseppe

    2017-11-01

    Global astrometry, very demanding in term of stability, requires extremely stable material for optical bench. CeSiC developed by ECM and Alcatel Alenia Space for mirrors and high stability structures, offers the best compromise in term of structural strength, stability and very high lightweight capability, with characteristics leading to be insensitive to thermo-elastic at cryogenic T°. The HSOB GAIA study realised by Alcatel Alenia Space under ESA contract aimed to design, develop and test a full scale representative High Stability Optical Bench in CeSiC. The bench has been equipped with SAGEIS-CSO laser metrology system MOUSE1, Michelson interferometer composed of integrated optics with a nm resolution. The HSOB bench has been submitted to an homogeneous T° step under vacuum to characterise the homothetic behaviour of its two arms. The quite negligible inter-arms differential measured with a nm range reproducibility, demonstrates that a complete 3D structure in CeSiC has the same CTE homogeneity as characterisation samples, fully in line with the GAIA need (1pm at 120K). This participates to the demonstration that CeSiC properties at cryogenic T° is fully appropriate to the manufacturing of complex highly stable optical structures. This successful study confirms ECM and Alcatel Alenia Space ability to define and manufacture monolithic lightweight highly stable optical structures, based on inner cells triangular design made only possible by the unique CeSiC manufacturing process.

  11. The effects of rest interval length on acute bench press performance: the influence of gender and muscle strength.

    Science.gov (United States)

    Ratamess, Nicholas A; Chiarello, Christina M; Sacco, Anthony J; Hoffman, Jay R; Faigenbaum, Avery D; Ross, Ryan E; Kang, Jie

    2012-07-01

    The purpose of this study was to investigate the effects of rest interval (RI) length on bench press performance in subjects with disparity in maximum strength. Two cohorts of subjects performed 3 bench press protocols in random order consisting of 3 sets of up to 10 repetitions with 75% of 1-repetition maximum (1RM) using either 1-, 2-, or 3-minute RIs between sets. In the first cohort, 22 men and women were studied to investigate gender influence. In the second cohort, 23 men were tested for 1RM bench press strength and placed into a low 1RM (mean = 80.7 ± 7.5 kg) or high 1RM (mean = 140.6 ± 11.9 kg) experimental group. The number of successful repetitions completed, average power, and velocity for each set were recorded. Women performed significantly more repetitions than men with 1-minute (26.9 ± 4.4 vs. 21.1 ± 3.5), 2-minute (29.0 ± 2.0 vs. 24.0 ± 4.5), and 3-minute (29.7 ± 1.8 vs. 25.8 ± 5.1) RIs. The magnitude of decline in average velocity and power was significantly higher in men than in women. Total number of repetitions performed was significantly greater in the low 1RM group than in the high 1RM group at 1-minute (21.6 ± 5.0 vs. 18.1 ± 2.0) and 2-minute RIs (24.2 ± 5.4 vs. 21.3 ± 2.8). Significant negative correlations were observed between 1RM bench press and total number of repetitions completed for 1- and 2-minute RIs (r = -0.558 and -0.490, respectively). These data indicate that maximal strength plays a role in bench press performance with varying RIs and suggest that shorter RIs may suffice in women to attain a specific volume.

  12. Effects of 5 Weeks of Bench Press Training on Muscle Synergies: A Randomized Controlled Study.

    Science.gov (United States)

    Kristiansen, Mathias; Samani, Afshin; Madeleine, Pascal; Hansen, Ernst A

    2016-07-01

    Kristiansen, M, Samani, A, Madeleine, P, and Hansen, EA. Effects of 5 weeks of bench press training on muscle synergies: A randomized controlled study. J Strength Cond Res 30(7): 1948-1959, 2016-The ability to perform forceful muscle contractions has important implications in sports performance and in activities of daily living. However, there is a lack of knowledge on adaptations in intermuscular coordination after strength training. The purpose of this study was therefore to assess muscle synergies before and after 5 weeks of bench press training. Thirty untrained male subjects were randomly allocated to a training group (TRA) or a control group (CON). After the pretest, TRA completed 5 weeks of bench press training, before completing a posttest, whereas subjects in CON continued their normal life. During test sessions, surface electromyography (EMG) was recorded from 13 different muscles. Muscle synergies were extracted from EMG data using nonnegative matrix factorization. To evaluate differences between pretest and posttest, we performed a cross-correlation analysis and a cross-validation analysis, in which the synergy components extracted in the pretest session were recomputed, using the fixed synergy components from the posttest session. Two muscle synergies accounted for 90% of the total variance and reflected the concentric and eccentric phase, respectively. TRA significantly increased 3 repetition maximum in bench press with 19.0% (25th; 75th percentile, 10.3%; 21.7%) (p < 0.001), whereas no change occurred in CON. No significant differences were observed in synergy components between groups. However, decreases in correlation values for intragroup comparisons in TRA may suggest that the synergy components changed, whereas this was not the case in CON. Strength and conditioning professionals may consider monitoring changes in muscle synergies in training and rehabilitation programs as a way to benchmark changes in intermuscular coordination.

  13. Optimal Velocity to Achieve Maximum Power Output – Bench Press for Trained Footballers

    Directory of Open Access Journals (Sweden)

    Richard Billich

    2015-03-01

    Full Text Available Optimal Velocity to Achieve Maximum Power Output – Bench Press for Trained Footballers In today’s world of strength training there are many myths surrounding effective exercising with the least possible negative effect on one’s health. In this experiment we focus on the finding of a relationship between maximum output, used load and the velocity with which the exercise is performed. The main objective is to find the optimal speed of the exercise motion which would allow us to reach the maximum mechanic muscle output during a bench press exercise. This information could be beneficial to sporting coaches and recreational sportsmen alike in helping them improve the effectiveness of fast strength training. Fifteen football players of the FK Třinec football club participated in the experiment. The measurements were made with the use of 3D cinematic and dynamic analysis, both experimental methods. The research subjects participated in a strength test, in which the mechanic muscle output of 0, 10, 30, 50, 70, 90% and one repetition maximum (1RM was measured. The acquired result values and other required data were modified using Qualisys Track Manager and Visual 3D software (C-motion, Rockville, MD, USA. During the bench press exercise the maximum mechanic muscle output of the set of research subjects was reached at 75% of maximum exercise motion velocity. Optimální rychlost pohybu pro dosažení maxima výstupního výkonu – bench press u trénovaných fotbalistů Dnešní svět silového tréninku přináší řadu mýtů o tom, jak cvičit efektivně a zároveň s co nejmenším negativním vlivem na zdraví člověka. V tomto experimentu se zabýváme nalezením vztahu mezi maximálním výkonem, použitou zátěží a rychlostí. Hlavním úkolem je nalezení optimální rychlosti pohybu pro dosažení maximálního mechanického svalového výkonu při cvičení bench press, což pomůže nejenom trenérům, ale i rekreačním sportovc

  14. Nonlinear Analysis of an Unstable Bench Press Bar Path and Muscle Activation.

    Science.gov (United States)

    Lawrence, Michael A; Leib, Daniel J; Ostrowski, Stephanie J; Carlson, Lara A

    2017-05-01

    Lawrence, MA, Leib, DJ, Ostrowski, SJ, and Carlson, LA. Nonlinear analysis of an unstable bench press bar path and muscle activation. J Strength Cond Res 31(5): 1206-1211, 2017-Unstable resistance exercises are typically performed to improve the ability of stabilizing muscles to maintain joint integrity under a load. The purpose of this study was to examine the effects of an unstable load (as provided by a flexible barbell and a load suspended by elastic bands) on the bar path, the primary musculature, and stabilizing musculature while bench pressing using nonlinear analyses. Fifteen resistance-trained men (age 24.2 ± 2.7 years, mass 84.1 ± 12.0 kg, height 1.77 ± 0.05 m, 9.9 ± 3.4 years of lifting experience, and bench press 1 repetition maximum (RM) 107.5 ± 25.9 kg) volunteered for this study. Subjects pressed 2 sets of 5 repetitions in both stable (total load 75% 1RM) and unstable (total load 60% 1RM) conditions using a standard barbell and a flexible Earthquake bar, respectively. Surface electromyography was used to detect muscle activity of primary movers (pectoralis major, anterior deltoid, and triceps) and bar stabilizing musculature (latissimus dorsi, middle and posterior deltoid, biceps brachii, and upper trapezius). During the unstable condition, the bar moved in more ways and was less predictable in the mediolateral and anteroposterior directions. However, the muscle activation patterns of all muscles were more constrained with the unstable barbell. These findings suggest that the unstable condition was more challenging to control, but subjects controlled the instability by contracting their muscles in a more stable pattern or "staying tight" throughout the exercise.

  15. Smith machine counterbalance system affects measures of maximal bench press throw performance.

    Science.gov (United States)

    Vingren, Jakob L; Buddhadev, Harsh H; Hill, David W

    2011-07-01

    Equipment with counterbalance weight systems is commonly used for the assessment of performance in explosive resistance exercise movements, but it is not known if such systems affect performance measures. The purpose of this study was to determine the effect of using a counterbalance weight system on measures of smith machine bench press throw performance. Ten men and 14 women (mean ± SD: age, 25 ± 4 years; height, 173 ± 10 cm; weight, 77.7 ± 18.3 kg) completed maximal smith machine bench press throws under 4 different conditions (2 × 2; counterbalance × load): with or without a counterbalance weight system and using 'light' or 'moderate' net barbell loads. Performance variables (peak force, peak velocity, and peak power) were measured using a linear accelerometer attached to the barbell. The counterbalance weight system resulted in significant (p velocity (light: -0.49 ± 0.10 m·s; moderate: -0.33 ± 0.07 m·s), and peak power (light: -220 ± 43 W; moderate: -143 ± 28 W) compared with no counterbalance system for both load conditions. Load condition did not affect absolute or percentage reductions from the counterbalance weight system for any variable. In conclusion, the use of a counterbalance weight system reduces accelerometer-based performance measures for the bench press throw exercise at light and moderate loads. This reduction in measures is likely because of an increase in the external resistance during the movement, which results in a discrepancy between the manually input and the actual value for external load. A counterbalance weight system should not be used when measuring performance in explosive resistance exercises with an accelerometer.

  16. Validity and reliability of a novel iPhone app for the measurement of barbell velocity and 1RM on the bench-press exercise

    OpenAIRE

    Balsalobre Fernández, Carlos; Marchante Domingo, David; Muñoz López, Mario; Jiménez Sáiz, Sergio Lorenzo

    2018-01-01

    The purpose of this study was to analyse the validity and reliability of a novel iPhone app (named: PowerLift) for the measurement of mean velocity on the bench-press exercise. Additionally, the accuracy of the estimation of the 1-Repetition maximum (1RM) using the load-velocity relationship was tested. To do this, 10 powerlifters (Mean (SD): age = 26.5 ± 6.5 years; bench press 1RM · kg-1 = 1.34 ± 0.25) completed an incremental test on the bench-press exercise with 5 different loads (75-100% ...

  17. Bench-mark experiments to study the neutron distribution in a heterogeneous reactor shielding

    International Nuclear Information System (INIS)

    Bolyatko, V.V.; Vyrskij, M.Yu.; Mashkovich, V.P.; Nagaev, R.Kh.; Prit'mov, A.P.; Sakharov, V.K.; Troshin, V.S.; Tikhonov, E.G.

    1981-01-01

    The bench-mark experiments performed at the B-2 facility of the BR-10 reactor to investigate the spatial and energy neutron distributions are described. The experimental facility includes the neutron beam channel with a slide, a mo shielding composition investigated consisted of sequential layers of steel (1KH18N9T) and graphite slabs. The neutron spectra were measured by activation method, a set of treshold and resonance detectors having been used. The detectors made it possible to obtain the absolute neutron spectra in the 1.4 eV-10 MeV range. The comparison of calculations with the results of the bench-mark experiments made it possible to prove the neutron transport calculational model realized in the ROZ-9 and ARAMAKO-2F computer codes and evaluate the validity of the ARAMAKO constants for the class of shielding compositions in question [ru

  18. Attentional Focus and Grip Width Influences on Bench Press Resistance Training.

    Science.gov (United States)

    Calatayud, Joaquin; Vinstrup, Jonas; Jakobsen, Markus D; Sundstrup, Emil; Colado, JuanCarlos; Andersen, Lars L

    2018-04-01

    This study evaluated the influence of different attentional foci for varied grip widths in the bench press. Eighteen resistance-trained men were familiarized with the procedure and performed a one-repetition maximum (1RM) test during Session 1. In Session 2, they used three different standardized grip widths (100%, 150%, and 200% of biacromial width distance) in random order at 50% of 1RM while also engaged in three different attention focus conditions (external focus on the bench press, internal focus on pectoralis major muscles, and internal focus on triceps brachii muscles). Surface electromyography (EMG) signals were recorded from the triceps brachii and pectoralis major, and peak EMG of the filtered signals were normalized to maximum EMG of each muscle. Both grip width and focus influenced the muscle activity level, but there were no significant interactions between these variables. Exploratory analyses suggested that an internal focus may slightly (4%-6%) increase pectoralis major activity at wider grip widths and triceps brachii activity at narrower grip widths, but this should be confirmed or rejected in a study with a larger sample size or through a meta-analysis of research to date.

  19. The effects of combined elastic- and free-weight tension vs. free-weight tension on one-repetition maximum strength in the bench press.

    Science.gov (United States)

    Bellar, David M; Muller, Matthew D; Barkley, Jacob E; Kim, Chul-Ho; Ida, Keisuke; Ryan, Edward J; Bliss, Mathew V; Glickman, Ellen L

    2011-02-01

    The present study investigated the effects of training combining elastic tension, free weights, and the bench press. Eleven college-aged men (untrained) in the bench press participated in the 13-week study. The participants were first given instructions and then practiced the bench press, followed by a one-repetition maximum (1RM) test of baseline strength. Subjects were then trained in the bench press for 3 weeks to allow for the beginning of neural adaptation. After another 1RM test, participants were assigned to 1 of 2 conditions for the next 3 weeks of training: 85% Free-Weight Tension, 15% Elastic Tension (BAND), or 100% Free-Weight Tension (STAND). After 3 weeks of training and a third 1RM max test, participants switched treatments, under which they completed the final 3 weeks of training and the fourth 1RM test. Analysis via analysis of covariance revealed a significant (p ≤ 0.05) main effect for time and interaction effect for Treatment (BAND vs. STAND). Subsequent analysis via paired-samples t-test revealed the BAND condition was significantly better (p = 0.05) at producing raw gains in 1RM strength. (BAND 9.95 ± 3.7 kg vs. STAND 7.56 ± 2.8 kg). These results suggest that the addition of elastic tension to the bench press may be an effective method of increasing strength.

  20. Long Rest Interval Promotes Durable Testosterone Responses in High-Intensity Bench Press.

    Science.gov (United States)

    Scudese, Estevão; Simão, Roberto; Senna, Gilmar; Vingren, Jakob L; Willardson, Jeffrey M; Baffi, Matheus; Miranda, Humberto

    2016-05-01

    The purpose of this study was to examine the influence of rest period duration (1 vs. 3 minute between sets) on acute hormone responses to a high-intensity and equal volume bench press workout. Ten resistance-trained men (25.2 ± 5.6 years; 78.2 ± 5.7 kg; 176.7 ± 5.4 cm; bench press relative strength: 1.3 ± 0.1 kg per kilogram of body mass) performed 2 bench press workouts separated by 1 week. Each workout consisted of 5 sets of 3 repetitions performed at 85% of 1 repetition maximum, with either 1- or 3-minute rest between sets. Circulating concentrations of total testosterone (TT), free testosterone (FT), cortisol (C), testosterone/cortisol ratio (TT/C), and growth hormone (GH) were measured at preworkout (PRE), and immediately (T0), 15 minutes (T15), and 30 minutes (T30) postworkout. Rating of perceived exertion was recorded before and after each set. For TT, both rest lengths enhanced all postexercise verifications (T0, T15, and T30) compared with PRE, with 1 minute showing decreases on T15 and T30 compared with T0. For FT, both 1- and 3-minute rest protocols triggered augmentations on distinct postexercise moments (T0 and T15 for 1 minute; T15 and T30 for 3-minute) compared with PRE. The C values did not change throughout any postexercise verification for either rests. The TT/C ratio was significantly elevated for both rests in all postexercise moments compared with PRE. Finally, GH values did not change for both rest lengths. In conclusion, although both short and long rest periods enhanced acute testosterone values, the longer rest promoted a long-lasting elevation for both TT and FT.

  1. The Effect of Rest Interval Length on Repetition Consistency and Perceived Exertion During Near Maximal Loaded Bench Press Sets.

    Science.gov (United States)

    Scudese, Estevão; Willardson, Jeffrey M; Simão, Roberto; Senna, Gilmar; de Salles, Belmiro F; Miranda, Humberto

    2015-11-01

    The purpose of this study was to compare different rest intervals between sets on repetition consistency and ratings of perceived exertion (RPE) during consecutive bench press sets with an absolute 3RM (3 repetition maximum) load. Sixteen trained men (23.75 ± 4.21 years; 74.63 ± 5.36 kg; 175 ± 4.64 cm; bench press relative strength: 1.44 ± 0.19 kg/kg of body mass) attended 4 randomly ordered sessions during which 5 consecutive sets of the bench press were performed with an absolute 3RM load and 1, 2, 3, or 5 minutes of rest interval between sets. The results indicated that significantly greater bench press repetitions were completed with 2, 3, and 5 minutes vs. 1-minute rest between sets (p ≤ 0.05); no significant differences were noted between the 2, 3, and 5 minutes rest conditions. For the 1-minute rest condition, performance reductions (relative to the first set) were observed commencing with the second set; whereas for the other conditions (2, 3, and 5 minutes rest), performance reductions were not evident until the third and fourth sets. The RPE values before each of the successive sets were significantly greater, commencing with the second set for the 1-minute vs. the 3 and 5 minutes rest conditions. Significant increases were also evident in RPE immediately after each set between the 1 and 5 minutes rest conditions from the second through fifth sets. These findings indicate that when utilizing an absolute 3RM load for the bench press, practitioners may prescribe a time-efficient minimum of 2 minutes rest between sets without significant impairments in repetition performance. However, lower perceived exertion levels may necessitate prescription of a minimum of 3 minutes rest between sets.

  2. A Simple Method for Assessing Upper-Limb Force-Velocity Profile in Bench Press.

    Science.gov (United States)

    Rahmani, Abderrahmane; Samozino, Pierre; Morin, Jean-Benoit; Morel, Baptiste

    2018-02-01

    To analyze the reliability and validity of a field computation method based on easy-to-measure data to assess the mean force ([Formula: see text]) and velocity ([Formula: see text]) produced during a ballistic bench-press movement and to verify that the force-velocity profile (F-v) obtained with multiple loaded trials is accurately described. Twelve participants performed ballistic bench presses against various lifted mass from 30% to 70% of their body mass. For each trial, [Formula: see text] and [Formula: see text] were determined from an accelerometer (sampling rate 500 Hz; reference method) and a simple computation method based on upper-limb mass, barbell flight height, and push-off distance. These [Formula: see text] and [Formula: see text] data were used to establish the F-v relationship for each individual and method. A strong to almost perfect reliability was observed between the 2 trials (ICC > .90 for [Formula: see text] and .80 for [Formula: see text], CV%  .80, P push-off distance).

  3. Geologic bench marks by terrestrial photography

    Science.gov (United States)

    Malde, Harold E.

    1973-01-01

    A photograph made with a level camera, if taken at a known height above a permanent mark on the ground, can be later repeated with exactness for measurement of changes in terrain. Such a photograph is one of several means for establishing a geologic bench mark and is especially useful for monitoring the subtle qualities of a landscape that are otherwise hard to map and describe, including the effects of man's use. Moreover, the geometry of such a photograph provides the same angular measurements between objects as can be made with a transit. A measurement of distance on a single photograph, however, requires control points. These can be surveyed at any convenient time, not necessarily when the initial photograph is made. Distances can also be determined by simple stereophotography from a base line of suitable length.

  4. Inter-Investigator Reliability of Anthropometric Prediction of 1RM Bench Press in College Football Players.

    Science.gov (United States)

    Schumacher, Richard M; Arabas, Jana L; Mayhew, Jerry L; Brechue, William F

    2016-01-01

    The purpose of this study was to determine the effect of inter-investigator differences in anthropometric assessments on the prediction of one-repetition maximum (1RM) bench press in college football players. Division-II players (n = 34, age = 20.4 ± 1.2 y, 182.3 ± 6.6 cm, 99.1 ± 18.4 kg) were measured for selected anthropometric variables and 1RM bench press at the conclusion of a heavy resistance training program. Triceps, subscapular, and abdominal skinfolds were measured in triplicate by three investigators and used to estimate %fat. Arm circumference was measured around a flexed biceps muscle and was corrected for triceps skinfold to estimate muscle cross-sectional area (CSA). Chest circumference was measured at mid-expiration. Significant differences among the testers were evident in six of the nine anthropometric variables, with the least experienced tester being significantly different from the other testers on seven variables, although average differences among investigators ranged from 1-2% for circumferences to 4-9% for skinfolds. The two more experienced testers were significantly different on only one variable. Overall agreement among testers was high (ICC>0.895) for each variable, with low coefficients of variation (CVbench press using a non-performance anthropometric equation. Minimal experience in anthropometry may not impede strength and conditioning specialists from accurately estimating 1RM bench press.

  5. Pollution effects on stone benches of the Eagle Warriors Precinct at the Major Temple, Mexico City

    International Nuclear Information System (INIS)

    Miranda, J.; Gallardo, M.L.; Grimaldi, D.M.; Roman-Berrelleza, J.A.; Ruvalcaba-Sil, J.L.; Ontalba Salamanca, M.A.; Morales, J.G.

    1999-01-01

    During Major Temple archaeological site excavations in Downtown Mexico City, the precinct of one of the most important Mexica military caste, the Eagle Warriors, was discovered. The ceremonial enclosure is composed of three rooms surrounded by paintings on 11 stone benches placed against the walls. Nowadays, these paintings and the stones present the effects of different deterioration processes produced by the underground water level, high humidity, and the presence of soil, water, and air pollutants. Ion beam analysis of samples from the benches and wall paintings was performed using PIXE and RBS techniques. Using enrichment factors of elements relative to iron concentrations, possible contamination by sulfur and chlorine salts was found, as well as airborne zinc scavenged by rain

  6. Development of a new bench for puncturing of irradiated fuel rods in STAR hot laboratory

    Science.gov (United States)

    Petitprez, B.; Silvestre, P.; Valenza, P.; Boulore, A.; David, T.

    2018-01-01

    A new device for puncturing of irradiated fuel rods in commercial power plants has been designed by Fuel Research Department of CEA Cadarache in order to provide experimental data of high precision on fuel pins with various designs. It will replace the current set-up that has been used since 1998 in hot cell 2 of STAR facility with more than 200 rod puncturing experiments. Based on this consistent experimental feedback, the heavy-duty technique of rod perforation by clad punching has been preserved for the new bench. The method of double expansion of rod gases is also retained since it allows upgrading the confidence interval of volumetric results obtained from rod puncturing. Furthermore, many evolutions have been introduced in the new design in order to improve its reliability, to make the maintenance easier by remote handling and to reduce experimental uncertainties. Tightness components have been studied with Sealing Laboratory Maestral at Pierrelatte so as to make them able to work under mixed pressure conditions (from vacuum at 10-5 mbar up to pressure at 50 bars) and to lengthen their lifetime under permanent gamma irradiation in hot cell. Bench ergonomics has been optimized to make its operating by remote handling easier and to secure the critical phases of a puncturing experiment. A high pressure gas line equipped with high precision pressure sensors out of cell can be connected to the bench in cell for calibration purposes. Uncertainty analyses using Monte Carlo calculations have been performed in order to optimize capacity of the different volumes of the apparatus according to volumetric characteristics of the rod to be punctured. At last this device is composed of independent modules which allow puncturing fuel pins out of different geometries (PWR, BWR, VVER). After leak tests of the device and remote handling simulation in a mock-up cell, several punctures of calibrated specimens have been performed in 2016. The bench will be implemented soon in hot

  7. The acute effects of a caffeine-containing supplement on bench press strength and time to running exhaustion.

    Science.gov (United States)

    Beck, Travis W; Housh, Terry J; Malek, Moh H; Mielke, Michelle; Hendrix, Russell

    2008-09-01

    The purpose of the present study was to examine the acute effects of a caffeine-containing supplement (SUPP) on one-repetition maximum (1-RM) bench press strength and time to running exhaustion (TRE) at a velocity that corresponded to 85% of the peak oxygen uptake ([latin capital V with dot above]O2peak). The study used a double-blinded, placebo-controlled, crossover design. Thirty-one men (mean +/- SD age = 23.0 +/- 2.6 years) were randomly assigned to take either the SUPP or placebo (PLAC) first. The SUPP contained 201 mg of caffeine, and the PLAC was microcrystalline cellulose. All subjects were tested for 1-RM bench press strength and TRE at 45 minutes after taking either the SUPP or PLAC. After 1 week of rest, the subjects returned to the laboratory and ingested the opposite substance (SUPP or PLAC) from what was taken during the previous visit. The 1-RM bench press and TRE tests were then performed in the same manner as before. The results indicated that the SUPP had no effect on 1-RM bench press strength or TRE at 85% [latin capital V with dot above]O2peak. It is possible that the acute effects of caffeine are affected by differences in training status and/or the relative intensity of the exercise task. Future studies should examine these issues, in addition to testing the acute effects of various caffeine doses on performance during maximal strength, power, and aerobic activities. These findings do not, however, support the use of caffeine as an ergogenic aid in untrained to moderately trained individuals.

  8. Comparison of electromyographic activity during the bench press and barbell pulloverexercises

    OpenAIRE

    Campos, Yuri de Almeida Costa; Silva, Sandro Fernandes da

    2014-01-01

    The aim of the study was to compare the electromyographic (EMG) activity of the following muscles: clavicular portion of pectoralis major, sternal portion of pectoralis major, long portion of triceps brachii, anterior deltoid, posterior deltoid and latissimus dorsi during dynamic contractions between flat horizontal bench press and barbell pulloverexercises. The sample comprised 12 males individuals experienced in resistance training. The volunteers made three visits to the laboratory. The fi...

  9. Performance study of protective clothing against hot water splashes: from bench scale test to instrumented manikin test.

    Science.gov (United States)

    Lu, Yehu; Song, Guowen; Wang, Faming

    2015-03-01

    Hot liquid hazards existing in work environments are shown to be a considerable risk for industrial workers. In this study, the predicted protection from fabric was assessed by a modified hot liquid splash tester. In these tests, conditions with and without an air spacer were applied. The protective performance of a garment exposed to hot water spray was investigated by a spray manikin evaluation system. Three-dimensional body scanning technique was used to characterize the air gap size between the protective clothing and the manikin skin. The relationship between bench scale test and manikin test was discussed and the regression model was established to predict the overall percentage of skin burn while wearing protective clothing. The results demonstrated strong correlations between bench scale test and manikin test. Based on these studies, the overall performance of protective clothing against hot water spray can be estimated on the basis of the results of the bench scale hot water splashes test and the information of air gap size entrapped in clothing. The findings provide effective guides for the design and material selection while developing high performance protective clothing. Published by Oxford University Press on behalf of the British Occupational Hygiene Society 2014.

  10. The Bench: An open drug scene and its people

    Directory of Open Access Journals (Sweden)

    Grønnestad Trond Erik

    2015-04-01

    Full Text Available AIMS - This article describes life in an open illicit drug milieu in a Norwegian city. This site, called “the Bench”, is a stigmatised place, and if one sits there, one is marked with the stigma of the place. Our aim is to gain insights into what stigmatised people gain from frequently visiting and staying in a public place that in itself is stigmatised. METHOD - One of the authors spent a year of participant observation, studying what went on at the Bench. He managed to build rapport in a gradual process of inclusion. The theoretical perspective rests on classic ethnography, symbolic interactionism and sociology on labelling and purity and dirt. RESULTS - “The Bench” is not only a local drug market, but also a social meeting place in which one can feel dignity, and where a certain humanisation process takes place through the rituals of everyday life. On “the Bench” it is possible to tell stories of decay, failures and shortcomings in life, stories that in other social arenas would be interpreted as symbols of stigma and degradation. “The Bench” is also a place in which different established power relations may be turned around through storytelling and jokes. This provides the bench-sitters with a sense of mutual control and agency. CONCLUSION - Socialising at “the Bench” is an expression of the need among social human beings to have their existences confirmed, in a society where they have been marginalised and looked upon as second-class citizens, as urban outcasts.

  11. Bench-marking effects in the blaming of professionals for incidents of aggression and assault.

    Science.gov (United States)

    Carifio, J; Lanza, M

    1994-01-01

    This study compared all possible orders of responding to three vignettes describing incidents between a male patient and a female nurse in which the nurse is mildly assaulted, severely assaulted, or verbally abused by the patient (the control condition). Subjects were 32 female senior-year nursing students and 28 practicing nurses. It was found that response levels to a given vignette could predict a respondent's response to the other vignettes. Also, a significant "bench-marking" effect was found: if a subject responded to the mild assault vignette first, the subject's overall response pattern best fit the general nonlinear assignment-of-blame pattern observed, but if the subject responded to the severe assault or control vignette first, this vignette set a bench mark for responding from which the subject's subsequent responses did not deviate greatly, which slightly distorted the subject's V-shaped nonlinear response pattern.

  12. Bench-Scale Demonstration of Hot-Gas Desulfurization Technology

    International Nuclear Information System (INIS)

    Portzer, Jeffrey W.; Gangwal, Santosh K.

    1997-01-01

    Prior to the current project, development of the DSRP was done in a laboratory setting, using synthetic gas mixtures to simulate the regeneration off-gas and coal gas feeds. The objective of the current work is to further the development of zinc titanate fluidized-bed desulfurization (ZTFBD) and the DSRP for hot-gas cleanup by testing with actual coal gas. The objectives of this project are to: (1) Develop and test an integrated, skid-mounted, bench-scale ZTFBD/DSRP reactor system with a slipstream of actual coal gas; (2) Test the bench-scale DSRP over an extended period with a slipstream of actual coal gas to quantify the degradation in performance, if any, caused by the trace contaminants present in coal gas (including heavy metals, chlorides, fluorides, and ammonia); (3) Expose the DSRP catalyst to actual coal gas for extended periods and then test its activity in a laboratory reactor to quantify the degradation in performance, if any, caused by static exposure to the trace contaminants in coal gas; (4) Design and fabricate a six-fold larger-scale DSRP reactor system for future slipstream testing; (5) Further develop the fluidized-bed DSRP to handle high concentrations (up to 14 percent) of SO 2 that are likely to be encountered when pure air is used for regeneration of desulfurization sorbents; and (6) Conduct extended field testing of the 6X DSRP reactor with actual coal gas and high concentrations of SO 2 . The accomplishment of the first three objectives--testing the DSRP with actual coal gas, integration with hot-gas desulfurization, and catalyst exposure testing--was described previously (Portzer and Gangwal, 1994, 1995; Portzer et al., 1996). This paper summarizes the results of previous work and describes the current activities and plans to accomplish the remaining objectives

  13. Bench-Scale Silicone Process for Low-Cost CO{sub 2} Capture

    Energy Technology Data Exchange (ETDEWEB)

    Wood, Benjamin; Genovese, Sarah; Perry, Robert; Spiry, Irina; Farnum, Rachael; Sing, Surinder; Wilson, Paul; Buckley, Paul; Acharya, Harish; Chen, Wei; McDermott, John; Vipperia, Ravikumar; Yee, Michael; Steele, Ray; Fresia, Megan; Vogt, Kirk

    2013-12-31

    A bench-scale system was designed and built to test an aminosilicone-based solvent. A model was built of the bench-scale system and this model was scaled up to model the performance of a carbon capture unit, using aminosilicones, for CO{sub 2} capture and sequestration (CCS) for a pulverized coal (PC) boiler at 550 MW. System and economic analysis for the carbon capture unit demonstrates that the aminosilicone solvent has significant advantages relative to a monoethanol amine (MEA)-based system. The CCS energy penalty for MEA is 35.9% and the energy penalty for aminosilicone solvent is 30.4% using a steam temperature of 395 °C (743 °F). If the steam temperature is lowered to 204 °C (400 °F), the energy penalty for the aminosilicone solvent is reduced to 29%. The increase in cost of electricity (COE) over the non-capture case for MEA is ~109% and increase in COE for aminosilicone solvent is ~98 to 103% depending on the solvent cost at a steam temperature of 395 °C (743 °F). If the steam temperature is lowered to 204 °C (400 °F), the increase in COE for the aminosilicone solvent is reduced to ~95-100%.

  14. The effects of grip width on sticking region in bench press.

    Science.gov (United States)

    Gomo, Olav; Van Den Tillaar, Roland

    2016-01-01

    The aim of this study was to examine the occurrence of the sticking region by examining how three different grip widths affect the sticking region in powerlifters' bench press performance. It was hypothesised that the sticking region would occur at the same joint angle of the elbow and shoulder independent of grip width, indicating a poor mechanical region for vertical force production at these joint angles. Twelve male experienced powerlifters (age 27.7 ± 8.8 years, mass 91.9 ± 15.4 kg) were tested in one repetition maximum (1-RM) bench press with a narrow, medium and wide grip. Joint kinematics, timing, bar position and velocity were measured with a 3D motion capture system. All participants showed a clear sticking region with all three grip widths, but this sticking region was not found to occur at the same joint angles in all three grip widths, thereby rejecting the hypothesis that the sticking region would occur at the same joint angle of the elbow and shoulder independent of grip width. It is suggested that, due to the differences in moment arm of the barbell about the elbow joint in the sticking region, there still might be a poor mechanical region for total force production that is joint angle-specific.

  15. A Bench Measurement of the Energy Loss of a Stored Beam to a Cavity

    Energy Technology Data Exchange (ETDEWEB)

    Sands, M; Rees, J.; /SLAC

    2016-12-19

    A rather simple electronic bench experiment is proposed for obtaining a measure of the impulse energy loss of a stored particle bunch to an rf cavity or other vacuum-chamber structure--the so-called "cavity radiation". The proposed method is analyzed in some detail.

  16. A bench top experimental model of bubble transport in multiple arteriole bifurcations

    International Nuclear Information System (INIS)

    Eshpuniyani, Brijesh; Fowlkes, J. Brian; Bull, Joseph L.

    2005-01-01

    Motivated by a novel gas embolotherapy technique, a bench top vascular bifurcation model is used to investigate the splitting of long bubbles in a series of liquid-filled bifurcations. The developmental gas embolotherapy technique aims to treat cancer by infarcting tumors with gas emboli that are formed by selective acoustic vaporization of ∼6 μm, intravascular, perfluorcarbon droplets. The resulting gas bubbles are large enough to extend through several vessel bifurcations. The current bench top experiments examine the effects of gravity and flow on bubble transport through multiple bifurcations. The effect of gravity is varied by changing the roll angle of the bifurcating network about its parent tube. Splitting at each bifurcation is nearly even when the roll angle is zero. It is demonstrated that bubbles can either stick at one of the second bifurcations or in the second generation daughter tubes, even though the flow rate in the parent tube is constant. The findings of this work indicate that both gravity and flow are important in determining the bubble transport, and suggest that a treatment strategy that includes multiple doses may be effective in delivering emboli to vessels not occluded by the initial dose

  17. Rest Interval Required for Power Training With Power Load in the Bench Press Throw Exercise.

    Science.gov (United States)

    Hernández Davó, Jose L; Solana, Rafael Sabido; Sarabia Marín, Jose M; Fernández Fernández, Jaime; Moya Ramón, Manuel

    2016-05-01

    This study aimed to test the influence of various rest interval (RI) durations used between sets on power output performance and physiological and perceptual variables during a strength training session using 40% of the 1 repetition maximum (1RM) in the bench press throw exercise. Thirty-one college students (18 males and 13 females) took part in the study. The experimental protocol consists of 5 sets of 8 repetitions of the bench press throw exercise with a load representing 40% of 1RM. Subjects performed the experimental protocol on 3 different occasions, differing by the RI between sets (1, 2, or 3 minutes). During the sessions, power data (mean power and peak power), physiological (lactate concentration [La]) and perceptual (rating of perceived exertion) variables were measured. In addition, delayed onset muscular soreness was reported 24 and 48 hours after the training session. One-way repeated-measures analysis of variance showed that 1-minute RI entailed higher power decreases and greater increases in values of physiological and perceptual variables compared with both 2- and 3-minute RIs. Nevertheless, no differences were found between 2- and 3-minute RIs. Therefore, this study showed that, when training with 40% of 1RM in the bench press throw exercise, a 2-minute RI between sets can be enough to avoid significant decreases in power output. Consequently, training sessions' duration could be reduced without causing excessive fatigue, allowing additional time to focus on other conditioning priorities.

  18. ValWorkBench: an open source Java library for cluster validation, with applications to microarray data analysis.

    Science.gov (United States)

    Giancarlo, R; Scaturro, D; Utro, F

    2015-02-01

    The prediction of the number of clusters in a dataset, in particular microarrays, is a fundamental task in biological data analysis, usually performed via validation measures. Unfortunately, it has received very little attention and in fact there is a growing need for software tools/libraries dedicated to it. Here we present ValWorkBench, a software library consisting of eleven well known validation measures, together with novel heuristic approximations for some of them. The main objective of this paper is to provide the interested researcher with the full software documentation of an open source cluster validation platform having the main features of being easily extendible in a homogeneous way and of offering software components that can be readily re-used. Consequently, the focus of the presentation is on the architecture of the library, since it provides an essential map that can be used to access the full software documentation, which is available at the supplementary material website [1]. The mentioned main features of ValWorkBench are also discussed and exemplified, with emphasis on software abstraction design and re-usability. A comparison with existing cluster validation software libraries, mainly in terms of the mentioned features, is also offered. It suggests that ValWorkBench is a much needed contribution to the microarray software development/algorithm engineering community. For completeness, it is important to mention that previous accurate algorithmic experimental analysis of the relative merits of each of the implemented measures [19,23,25], carried out specifically on microarray data, gives useful insights on the effectiveness of ValWorkBench for cluster validation to researchers in the microarray community interested in its use for the mentioned task. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  19. Rhode Island Flood Plain Management Services; Bench & Reference Mark Catalogue Portsmouth, Newport and Warwick, Rhode Island

    National Research Council Canada - National Science Library

    Hatfield, Christopher

    1994-01-01

    This study, which developed a catalog of bench and reference marks for several communities in Rhode Island, was conducted by the Long Range Planning Branch, Planning Directorate, New England Division, U.S...

  20. Design and test of the benches for the magnetic measurement of the LHC dipoles

    International Nuclear Information System (INIS)

    Billan, J.; Buckley, J.; Saban, R.; Sievers, P.; Walckiers, L.

    1994-01-01

    The magnetic measurement of more than 1,300 LHC dipoles comprises the content of higher harmonic field components, field direction and field integrals. The measurements will be carried out along a warm bore installed inside the magnet cold bore, thus allowing the use of rotating coils at room temperature. This coil, together with Hall and NMR detectors is mounted at one end of a 12.5 m long shaft which is specially designed for very high rotational stiffness and which is controlled from its far end by a motor, an angular encoder and a level meter, all standard components placed outside the magnetic field without space restrictions. Particular emphasis has been put on the user-friendliness of the bench and its automated, computer-controlled operation requiring a minimum of staff, an important issue during production measurements of large series of magnets. The bench and its performed and precision achieved during its commissioning are described

  1. A New Approach to EMG Analysis of Closed-Circuit Movements Such as the Flat Bench Press

    Directory of Open Access Journals (Sweden)

    Artur Golas

    2018-03-01

    Full Text Available Background: The bench press (BP is a complex exercise demanding high neuromuscular activity. Therefore, the main objective of this study was to identify the patterns of muscular activity of the prime movers on both sides of an elite powerlifter. Methods: A World Champion (RAW PR 320 kg participated in the study (age: 34 years; body mass: 103 kg; body height 1.72 m; one-repetition maximum (1 RM flat bench press: 220 kg. The subject performed one repetition of the flat bench press with: 70% 1 RM (150 kg and 90% 1 RM (200 kg in tempos: 2 s eccentric and 1 s concentric phase; 6 s eccentric and 1 s concentric phase. The activity was recorded for: pectoralis major, anterior deltoid, and triceps brachii (lateral and long head. Results: The total sum of peak muscle activity for the four analyzed muscles during both phases of the BP with the different loads and tempos was significantly different, and greater on the right side of the body. Conclusions: The use of lighter loads activate muscle groups in a different activation level, allowing for a greater muscle control. Lifting submaximal and maximal loads causes an activation of most motor units involved in the movement. Experienced athletes have a stabilized neuromuscular pattern for lifting which has different bilateral activity contribution.

  2. The relationship between muscle action and repetition maximum on the squat and bench press in men and women.

    Science.gov (United States)

    Flanagan, Shawn D; Mills, Matthew D; Sterczala, Adam J; Mala, Jesse; Comstock, Brett A; Szivak, Tunde K; DuPont, William H; Looney, David P; McDermott, Danielle M; Hooper, David R; White, Mark T; Dunn-Lewis, Courtenay; Volek, Jeff S; Maresh, Carl M; Kraemer, William J

    2014-09-01

    The relationship between muscle action and fatigue is not well understood, especially in terms of potential sex-specific differences. The purpose of this investigation was to determine whether a different number of repetitions could be performed on the individual muscle actions of the bench press and squat in men and women. Ten resistance-trained men (n = 10; age, 25.2 ± 1.2 years; height, 178.6 ± 8.8 cm; weight, 91.4 ± 18.1 kg; body fat, 12.7 ± 3.6%) and women (n = 10; age, 25.4 ± 2.4 years; height, 164 ± 4.0 cm; weight, 58.45 ± 3.3 kg; body fat, 20.8 ± 1.5%) participated in this balanced and randomized within-group study. Using 85% of a 1 repetition maximum, over the course of 3 visits, subjects performed 1 eccentric (ECC), concentric (CON), or combined (COMB) set to failure on the squat and bench press. Differences in muscle action and sex-specific number of repetitions to failure were compared on the squat and bench press, where significance was p ≤ 0.05. Across both exercises and sex, we observed significant differences between each of the 3 muscle actions, where the number of repetitions decreased from ECC to COMB to CON. While no sex-specific differences were observed in the squat, women performed significantly more repetitions on the ECC and CON muscle actions of the bench press. Men performed more combined repetitions, however, indicating a greater reliance on the stretch-shortening cycle. Different muscle actions contribute uniquely to the successful performance of a lift and fatigue. These contributions appear to differ in men and women.

  3. Genifuel Hydrothermal Processing Bench Scale Technology Evaluation Project (WE&RF Report LIFT6T14)

    Science.gov (United States)

    Hydrothermal Liquefaction (HTL) and Catalytic Hydrothermal Gasification (CHG) proof-of-concept bench-scale tests were performed to assess the potential of the Genifuel hydrothermal process technology for handling municipal wastewater sludge. HTL tests were conducted at 300-350◦C ...

  4. Influence of bench press exercise modality on the iso-inertial performance

    OpenAIRE

    Jidovtseff, Boris; Croisier, Jean-Louis; Crielaard, Jean-Michel

    2006-01-01

    Introduction. - This study used an iso-inertial dynamometer to investigate the influence of counter-movement and barbell throwing during bench press exercise. A critical analysis of these modalities during muscular evaluation was also performed. Methods. - The action of muscle stretch during the counter-movement induced an increase in average velocity and a shortening of the time to reach the peak power and peak velocity. The barbell throwing did not alter the initial part of the movement yet...

  5. Bench top and portable mineral analysers, borehole core analysers and in situ borehole logging

    International Nuclear Information System (INIS)

    Howarth, W.J.; Watt, J.S.

    1982-01-01

    Bench top and portable mineral analysers are usually based on balanced filter techniques using scintillation detectors or on low resolution proportional detectors. The application of radioisotope x-ray techniques to in situ borehole logging is increasing, and is particularly suited for logging for tin and higher atomic number elements

  6. Fatigue effects on bar kinematics during the bench press.

    Science.gov (United States)

    Duffey, Michael J; Challis, John H

    2007-05-01

    The bench press is one of the most popular weight training exercises. Although most training regimens incorporate multiple repetition sets, there are few data describing how the kinematics of a lift change during a set to failure. To examine these changes, recreational lifters (10 men and 8 women) were recruited. The maximum weight each subject could bench press (1RM) was determined. Subjects then performed as many repetitions as possible at 75% of the 1RM load. Three-dimensional kinematic data were recorded and analyzed for all lifts. Statistical analysis revealed that differences between maximal and submaximal lifts and the kinematics of a submaximal lift change as a subject approaches failure in a set. The time to lift the bar more than doubled from the first to the last repetition, causing a decrease in both mean and peak upward velocity. Furthermore, the peak upward velocity occurred much earlier in the lift phase in these later repetitions. The path the bar followed also changed, with subjects keeping the bar more directly over the shoulder during the lift. In general, most of the kinematic variables analyzed became more similar to those of the maximal lift as the subjects progressed through the set, but there was considerable variation between subjects as to which repetition was most like the maximal lift. This study shows that there are definite changes in the lifting kinematics in recreational lifters during a set to failure and suggests it may be particularly important for coaches and less-skilled lifters to focus on developing the proper bar path, rather than reaching momentary muscular failure, in the early part of a training program.

  7. Bench-Scale Evaluation of Peracetic Acid and Twin Oxide ™ as Disinfectants in Drinking Water

    Science.gov (United States)

    Chlorine is widely used as an inexpensive and potent disinfectant in the United States for drinking water. However, chlorine has the potential for forming carcinogenic and mutagenic disinfection by-products (DBPs). In this study, bench scale experiments were conducted at the U.S...

  8. Effects of whole-body vibration applied to lower extremity muscles during decline bench press exercise.

    Science.gov (United States)

    García-Gutiérrez, M T; Hazell, T J; Marín, P J

    2016-09-07

    To evaluate the effects of whole-body vibration (WBV) on skeletal muscle activity and power performance of the upper body during decline bench press exercise at different loads. Forty-seven healthy young and active male students volunteered. Each performed dynamic decline bench press repetitions with and without WBV (50 Hz, 2.2 mm) applied through a hamstring bridge exercise at three different loads of their 1-repetition maximum (1RM): 30%, 50%, and 70% 1RM. Muscle activity of the triceps brachii (TB), biceps brachii (BB), pectoralis major (PM), and biceps femoris (BF) was measured with surface electromyography electrodes and kinetic parameters of the repetitions were measured with a rotary encoder. WBV increased peak power (PP) output during the 70% 1RM condition (pbench press and this augmentation contributes to an increased peak power at higher loads and increased peak acceleration at lower loads.

  9. Validity and Reliability of a Wearable Inertial Sensor to Measure Velocity and Power in the Back Squat and Bench Press.

    Science.gov (United States)

    Orange, Samuel T; Metcalfe, James W; Liefeith, Andreas; Marshall, Phil; Madden, Leigh A; Fewster, Connor R; Vince, Rebecca V

    2018-05-08

    Orange, ST, Metcalfe, JW, Liefeith, A, Marshall, P, Madden, LA, Fewster, CR, and Vince, RV. Validity and reliability of a wearable inertial sensor to measure velocity and power in the back squat and bench press. J Strength Cond Res XX(X): 000-000, 2018-This study examined the validity and reliability of a wearable inertial sensor to measure velocity and power in the free-weight back squat and bench press. Twenty-nine youth rugby league players (18 ± 1 years) completed 2 test-retest sessions for the back squat followed by 2 test-retest sessions for the bench press. Repetitions were performed at 20, 40, 60, 80, and 90% of 1 repetition maximum (1RM) with mean velocity, peak velocity, mean power (MP), and peak power (PP) simultaneously measured using an inertial sensor (PUSH) and a linear position transducer (GymAware PowerTool). The PUSH demonstrated good validity (Pearson's product-moment correlation coefficient [r]) and reliability (intraclass correlation coefficient [ICC]) only for measurements of MP (r = 0.91; ICC = 0.83) and PP (r = 0.90; ICC = 0.80) at 20% of 1RM in the back squat. However, it may be more appropriate for athletes to jump off the ground with this load to optimize power output. Further research should therefore evaluate the usability of inertial sensors in the jump squat exercise. In the bench press, good validity and reliability were evident only for the measurement of MP at 40% of 1RM (r = 0.89; ICC = 0.83). The PUSH was unable to provide a valid and reliable estimate of any other criterion variable in either exercise. Practitioners must be cognizant of the measurement error when using inertial sensor technology to quantify velocity and power during resistance training, particularly with loads other than 20% of 1RM in the back squat and 40% of 1RM in the bench press.

  10. In situ remediation of hexavalent chromium with pyrite fines : bench scale demonstration

    International Nuclear Information System (INIS)

    Cathum, S.; Wong, W.P.; Brown, C.E.

    2002-01-01

    An in situ remediation technique for chromium contaminated soil with pyrite fines was presented. Past industrial activities and lack of disposal facilities have contributed to a serious problem dealing with chromium, which cannot be eliminated from the environment because it is an element. Both bench-scale and laboratory testing was conducted to confirm the efficiency of the proposed process which successfully converted Cr(VI) into Cr(III) in soil and water. Cr(III) is less toxic and immobile in the environment compared to Cr(VI) which moves freely in the soil matrix, posing a risk to the groundwater quality. pH in the range of 2.0 to 7.6 has no effect on the reactivity of pyrite towards Cr(VI). The optimization of the bench-scale treatment resulted in a large volume of chromium waste, mostly from the control experiments and column hydrology testing. These waste streams were treated according to municipal guidelines before disposal to the environment. Samples of chromium waste before and after treatment were analyzed. Cr (VI) was completely mineralized to below guideline levels. It was determined that several conditions, including contact time between pyrite and Cr(VI), are crucial for complete mineralization of Cr(VI). 13 refs., 8 tabs., 9 figs

  11. Study of the boron homogenizing process employing an experimental low-pressure bench simulating the IRIS reactor pressurizer – Part I

    International Nuclear Information System (INIS)

    Bezerra, Jair de Lima; Lira, Carlos Alberto Brayner de Oliveira; Barroso, Antonio Carlos de Oliveira; Lima, Fernando Roberto de Andrade; Bezerra da Silva, Mário Augusto

    2013-01-01

    Highlights: ► Experimental bench with test section made of transparent acrylic, simulating the pressurizer reactor IRIS. ► Workbench used to study the process of homogenization of boron in the pressurizer IRIS nuclear reactor. ► Results were obtained through videos and digital photos of the test section. - Abstract: The reactivity control of a nuclear reactor to pressurized water is made by means of controlling bars or by boron dilution in the water from the coolant of a primary circuit. The control with boron dilution has great importance, despite inserting small variations in the reactivity in the reactor, as it does not significantly affect the distribution of the neutron flux. A simplified experimental bench with a test section manufactured in transparent acrylic, was built in reduced scale as to be used in a boron homogenizing process, simulating an IRIS reactor pressurizer (International Reactor Innovative and Secure). The bench was assembled in the Centro Regional de Ciências Nucleares do Nordeste (CRCN-NE), an entity linked to the Comissão Nacional de Energia Nuclear (CNEN), Recife – PE

  12. Study of the boron homogenizing process employing an experimental low-pressure bench simulating the IRIS reactor pressurizer – Part II

    International Nuclear Information System (INIS)

    Bezerra, Jair de Lima; Lira, Carlos Alberto Brayner de Oliveira; Barroso, Antonio Carlos de Oliveira; Lima, Fernando Roberto de Andrade; Silva, Mário Augusto Bezerra da

    2013-01-01

    Highlights: • Experimental bench with test section made of transparent acrylic, simulating the pressurizer reactor IRIS. • Workbench used to study the process of homogenization of boron in the pressurizer IRIS nuclear reactor. • Results were obtained through videos and digital photos of the test section. - Abstract: The reactivity control of a nuclear reactor to pressurized water is made by means of controlling bars or by boron dilution in the water from the coolant of a primary circuit. The control with boron dilution has great importance, despite inserting small variations in the reactivity in the reactor, as it does not significantly affect the distribution of the neutron flux. A simplified experimental bench with a test section manufactured in transparent acrylic, was built in reduced scale as to be used in a boron homogenizing process, simulating an IRIS reactor pressurizer (International Reactor Innovative and Secure). The bench was assembled in the Centro Regional de Ciências Nucleares do Nordeste (CRCN-NE), an entity linked to the Comissão Nacional de Energia Nuclear (CNEN), Recife–PE

  13. Effect of instructions on EMG during the bench press in trained and untrained males.

    Science.gov (United States)

    Daniels, Rebecca J; Cook, Summer B

    2017-10-01

    Strength and rehabilitation professionals strive to emphasize certain muscles used during an exercise and it may be possible to alter muscle recruitment strategies with varying instructions. This study aimed to determine whether resistance trained and untrained males could selectively activate the pectoralis major or triceps brachii during the bench press according to various instructions. This study included 13 trained males (21.5±2.9years old, 178.7±7.0cm, 85.7±10.7kg) and 12 untrained males (20.3±1.6years old, 178.8±9.4cm, 74.6±17.3kg). Participants performed a bench press one-repetition maximum (1-RM) test, 3 uninstructed repetitions at 80% 1-RM and two more sets of three repetitions with instructions to isolate the chest or arm muscles. Electromyography (EMG) was obtained from the pectoralis major, anterior deltoid, and the long head and short head of the triceps brachii. Maximum EMG activity normalized to 1-RM for each muscle was averaged over the three repetitions for each set and compared between the uninstructed, chest-instructed and arm-instructed conditions among the groups. The trained participants had a greater 1-RM (126.2±30.6kg) than the untrained participants (61.6±14.8kg) (P0.05). When the group data was combined, short head of the triceps activity was significantly lower in the chest instruction (80.1±19.3%) when compared to the uninstructed (85.6±23.3%; P=0.01) and arm-instructed (86.0±23.2; P=0.01) conditions. It can be concluded that instructions can affect muscle activation during the bench press, and this is not dependent on training status. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Free-Weight Augmentation With Elastic Bands Improves Bench Press Kinematics in Professional Rugby Players.

    Science.gov (United States)

    García-López, David; Hernández-Sánchez, Sonsoles; Martín, Esperanza; Marín, Pedro J; Zarzosa, Fernando; Herrero, Azael J

    2016-09-01

    García-López, D, Hernández-Sánchez, S, Martín, E, Marín, PJ, Zarzosa, F, and Herrero, AJ. Free-weight augmentation with elastic bands improves bench press kinematics in professional rugby players. J Strength Cond Res 30(9): 2493-2499, 2016-This study aimed to investigate the effects of combining elastic bands to free weight resistance (EB + FWR) on the acceleration-deceleration and velocity profiles of the bench press in professional rugby players and recreationally trained subjects. Sixteen male subjects (8 rugby players and 8 recreationally trained subjects) were randomly assigned to complete 2 experimental conditions in a crossover fashion: EB + FWR and FWR. In both conditions, subjects performed 1 bench press set to volitional exhaustion with a load equivalent to the 85% of 1 repetition maximum (1RM). In the EB + FWR condition, the contribution of elastic resistance was approximately 20% of the selected load (85% 1RM). Results indicate that EB + FWR condition increased significantly the range of concentric movement in which the barbell is accelerated. This increase was significantly higher in rugby players (35%) in comparison with recreationally trained subjects (13%). Maximal velocity was also increased in EB + FWR (17%), when compared with FWR condition. These results suggest that when combined with variable resistance (i.e., EB), the external resistance seems to be more evenly distributed over the full range of motion, decreasing the need for dramatic deceleration at the end of the concentric phase. The present data also indicate that the kinematic benefits of an EB + FWR approach seems to be more prominent in athletes from modalities in which high level of strength and power are required (i.e., rugby players).

  15. Quality Assessment of Vertical Angular Deviations for Photometer Calibration Benches

    International Nuclear Information System (INIS)

    Ribeiro, A Silva; Santos, A Costa; E Sousa, J Alves; Forbes, A B

    2015-01-01

    Lighting, both natural and electric, constitutes one of the most important aspects of the life of human beings, allowing us to see and perform our daily tasks in outdoor and indoor environments. The safety aspects of lighting are self-evident in areas such as road lighting, urban lighting and also indoor lighting. The use of photometers to measure lighting levels requires traceability obtained in accredited laboratories, which must provide an associated uncertainty. It is therefore relevant to study the impact of known uncertainty sources like the vertical angular deviation of photometer calibration benches, in order to define criteria to its quality assessment

  16. STS-65 crewmembers participate in bench review at Boeing Building

    Science.gov (United States)

    1994-01-01

    Attired in clean suits, STS-65 Payload Commander (PLC) Richard J. Hieb (left) and Payload Specialist Chiaki Mukai examine the contents of a stowage locker during a bench review at Boeing's Flight Equipment Processing Facility (FEPF) near the Johnson Space Center (JSC). In the background, Commander Robert D. Cabana inspects additional equipment to be carried aboard the Space Shuttle Columbia, Orbiter Vehicle (OV) 102, for the scheduled July flight of the second International Microgravity Laboratory (IML-2) mission. Mukai represents Japan's National Space Development Agency (NASDA). Photo taken by NASA JSC contract photographer Scott A. Wickes.

  17. Environmental data from laboratory- and bench-scale Pressurized Fluidized-Bed Hydroretorting of Eastern oil shale

    Energy Technology Data Exchange (ETDEWEB)

    Mensinger, M.C.; Rue, D.M.; Roberts, M.J.

    1991-01-01

    As part of a 3-year program to develop the Pressurized Fluidized-Bed Hydroretorting (PFH) Process for Eastern oil shales, IGT conducted tests in laboratory-scale batch and continuous units as well as a 45-kg/h bench-scale unit to generate a data base for 6 Eastern shales. Data were collected during PFH processing of raw Alabama and Indiana shales and a beneficiated Indiana shale for environmental mitigation analyses. The data generated include trace element analyses of the raw feeds and spent shales, product oils, and sour waters. The sulfur compounds present in the product gas and trace components in the sour water were also determined. In addition, the leaching characteristics of the feed and residue solids were determined. The data obtained were used to evaluate the environmental impact of a shale processing plant based on the PFH process. This paper presents the environmental data obtained from bench-scale tests conducted during the program.

  18. Environmental data from laboratory- and bench-scale Pressurized Fluidized-Bed Hydroretorting of Eastern oil shale

    Energy Technology Data Exchange (ETDEWEB)

    Mensinger, M.C.; Rue, D.M.; Roberts, M.J.

    1991-12-31

    As part of a 3-year program to develop the Pressurized Fluidized-Bed Hydroretorting (PFH) Process for Eastern oil shales, IGT conducted tests in laboratory-scale batch and continuous units as well as a 45-kg/h bench-scale unit to generate a data base for 6 Eastern shales. Data were collected during PFH processing of raw Alabama and Indiana shales and a beneficiated Indiana shale for environmental mitigation analyses. The data generated include trace element analyses of the raw feeds and spent shales, product oils, and sour waters. The sulfur compounds present in the product gas and trace components in the sour water were also determined. In addition, the leaching characteristics of the feed and residue solids were determined. The data obtained were used to evaluate the environmental impact of a shale processing plant based on the PFH process. This paper presents the environmental data obtained from bench-scale tests conducted during the program.

  19. Evaluation of malodor for automobile air conditioner evaporator by using laboratory-scale test cooling bench.

    Science.gov (United States)

    Kim, Kyung Hwan; Kim, Sun Hwa; Jung, Young Rim; Kim, Man Goo

    2008-09-12

    As one of the measures to improve the environment in an automobile, malodor caused by the automobile air-conditioning system evaporator was evaluated and analyzed using laboratory-scale test cooling bench. The odor was simulated with an evaporator test cooling bench equipped with an airflow controller, air temperature and relative humidity controller. To simulate the same odor characteristics that occur from automobiles, one previously used automobile air conditioner evaporator associated with unpleasant odors was selected. The odor was evaluated by trained panels and collected with aluminum polyester bags. Collected samples were analyzed by thermal desorption into a cryotrap and subsequent gas chromatographic separation, followed by simultaneous olfactometry, flame ionization detector and identified by atomic emission detection and mass spectrometry. Compounds such as alcohols, aldehydes, and organic acids were identified as responsible odor-active compounds. Gas chromatography/flame ionization detection/olfactometry combined sensory method with instrumental analysis was very effective as an odor evaluation method in an automobile air-conditioning system evaporator.

  20. Inter- and Intrasubject Similarity of Muscle Synergies During Bench Press With Slow and Fast Velocity.

    Science.gov (United States)

    Samani, Afshin; Kristiansen, Mathias

    2018-01-01

    We investigated the effect of low and high bar velocity on inter- and intrasubject similarity of muscle synergies during bench press. A total of 13 trained male subjects underwent two exercise conditions: a slow- and a fast-velocity bench press. Surface electromyography was recorded from 13 muscles, and muscle synergies were extracted using a nonnegative matrix factorization algorithm. The intrasubject similarity across conditions and intersubject similarity within conditions were computed for muscle synergy vectors and activation coefficients. Two muscle synergies were sufficient to describe the dataset variability. For the second synergy activation coefficient, the intersubject similarity within the fast-velocity condition was greater than the intrasubject similarity of the activation coefficient across the conditions. An opposite pattern was observed for the first muscle synergy vector. We concluded that the activation coefficients are robust within conditions, indicating a robust temporal pattern of muscular activity across individuals, but the muscle synergy vector seemed to be individually assigned.

  1. A new portable test bench for the ATLAS Tile Calorimeter front-end electronics certification

    International Nuclear Information System (INIS)

    Alves, J.; Carrio, F.; Moreno, P.; Usai, G.; Valero, A.; Kim, H.Y.; Minashvili, I.; Shalyugin, A.; Reed, R.; Schettino, V.; Souza, J.; Solans, C.

    2013-06-01

    This paper describes the upgraded portable test bench for the Tile Calorimeter of the ATLAS experiment at CERN. The previous version of the portable test bench was extensively used for certification and qualification of the front-end electronics during the commissioning phase as well as during the short maintenance periods of 2010 and 2011. The new version described here is designed to be an easily upgradable version of the 10-year-old system, able to evaluate the new technologies planned for the ATLAS upgrade as well as provide new functionalities to the present system. It will be used in the consolidation of electronics campaign during the long shutdown of the LHC in 2013-14 and during future maintenance periods. The system, based on a global re-design with state-of-the-art devices, is based on a back-end electronics crate instrumented with commercial and custom modules and a front-end GUI that is executed on an external portable computer and communicates with the controller in the crate through an Ethernet connection. (authors)

  2. Cellular and Molecular Anesthesia: from Bench to Bedside

    Directory of Open Access Journals (Sweden)

    Ali Dabbagh

    2015-12-01

    Full Text Available Cellular and Molecular Anesthesia: from Bench to BedsideIn the current practice of anesthesia, each day, anesthesiologists deal with a great work: they use the cellular mechanisms of drug molecules to induce their desired effects for induction and maintenance of anesthesia to achieve appropriate tolerance of surgery and its pain, modulation of stress response, sedation needed for performing a variety of procedures, emergency anesthesia care, acute and chronic pain management or other everyday jobs of anesthesiologists during perioperative period.As a matter of fact, molecular anesthesia has been cited for more than 6 decades though in avery limited scale. In 1956, the molecular mechanisms of morphine and pethidine are described (1. Pauling in 1961 published an article in Science describing a molecular theorey for general anesthesia (2.In its report “the World in 2025”, Thomson Reuters has predicted clinical medicine would be the most active research front; while molecular biology has the 9th rank (3. But are we still practicing in clinic the same as today?In fact, the future trend of anesthesia is highly dependent on finding the novel cellular and molecular mechanisms and the possible interactions of the newly discovered molecules and inreraction mechanisms with organ systems. Today, we emphasize on the role of pharmacologists, physiologists, immunologists, anatomists, embryologists, geneticians, cellular medicine specialists, physicists and other basic science specialists; some very interesting examples are published in this volume of the Journal (4-7.However, changes that have well started now would “revolutionize” our daily practice during the next decade in such a way that it will change the basis of medicine: presumably we will have a new model medicine known as “personalized medicine” or “precision medicine”. In this approach, the content of each patient’s genes accompanied with his/her cellular and molecular analysis is

  3. Validity and reliability of a novel iPhone app for the measurement of barbell velocity and 1RM on the bench-press exercise.

    Science.gov (United States)

    Balsalobre-Fernández, Carlos; Marchante, David; Muñoz-López, Mario; Jiménez, Sergio L

    2018-01-01

    The purpose of this study was to analyse the validity and reliability of a novel iPhone app (named: PowerLift) for the measurement of mean velocity on the bench-press exercise. Additionally, the accuracy of the estimation of the 1-Repetition maximum (1RM) using the load-velocity relationship was tested. To do this, 10 powerlifters (Mean (SD): age = 26.5 ± 6.5 years; bench press 1RM · kg -1  = 1.34 ± 0.25) completed an incremental test on the bench-press exercise with 5 different loads (75-100% 1RM), while the mean velocity of the barbell was registered using a linear transducer (LT) and Powerlift. Results showed a very high correlation between the LT and the app (r = 0.94, SEE = 0.028 m · s -1 ) for the measurement of mean velocity. Bland-Altman plots (R 2  = 0.011) and intraclass correlation coefficient (ICC = 0.965) revealed a very high agreement between both devices. A systematic bias by which the app registered slightly higher values than the LT (P velocity in the bench-press exercise.

  4. Tests of the Daimler D-IVa Engine at a High Altitude Test Bench

    Science.gov (United States)

    Noack, W G

    1920-01-01

    Reports of tests of a Daimler IVa engine at the test-bench at Friedrichshafen, show that the decrease of power of that engine, at high altitudes, was established, and that the manner of its working when air is supplied at a certain pressure was explained. These tests were preparatory to the installation of compressors in giant aircraft for the purpose of maintaining constant power at high altitudes.

  5. Development of 1RM Prediction Equations for Bench Press in Moderately Trained Men.

    Science.gov (United States)

    Macht, Jordan W; Abel, Mark G; Mullineaux, David R; Yates, James W

    2016-10-01

    Macht, JW, Abel, MG, Mullineaux, DR, and Yates, JW. Development of 1RM prediction equations for bench press in moderately trained men. J Strength Cond Res 30(10): 2901-2906, 2016-There are a variety of established 1 repetition maximum (1RM) prediction equations, however, very few prediction equations use anthropometric characteristics exclusively or in part, to estimate 1RM strength. Therefore, the purpose of this study was to develop an original 1RM prediction equation for bench press using anthropometric and performance characteristics in moderately trained male subjects. Sixty male subjects (21.2 ± 2.4 years) completed a 1RM bench press and were randomly assigned a load to complete as many repetitions as possible. In addition, body composition, upper-body anthropometric characteristics, and handgrip strength were assessed. Regression analysis was used to develop a performance-based 1RM prediction equation: 1RM = 1.20 repetition weight + 2.19 repetitions to fatigue - 0.56 biacromial width (cm) + 9.6 (R = 0.99, standard error of estimate [SEE] = 3.5 kg). Regression analysis to develop a nonperformance-based 1RM prediction equation yielded: 1RM (kg) = 0.997 cross-sectional area (CSA) (cm) + 0.401 chest circumference (cm) - 0.385%fat - 0.185 arm length (cm) + 36.7 (R = 0.81, SEE = 13.0 kg). The performance prediction equations developed in this study had high validity coefficients, minimal mean bias, and small limits of agreement. The anthropometric equations had moderately high validity coefficient but larger limits of agreement. The practical applications of this study indicate that the inclusion of anthropometric characteristics and performance variables produce a valid prediction equation for 1RM strength. In addition, the CSA of the arm uses a simple nonperformance method of estimating the lifter's 1RM. This information may be used to predict the starting load for a lifter performing a 1RM prediction protocol or a 1RM testing protocol.

  6. Monitoring of noninvasive ventilation by built-in software of home bilevel ventilators: a bench study.

    Science.gov (United States)

    Contal, Olivier; Vignaux, Laurence; Combescure, Christophe; Pepin, Jean-Louis; Jolliet, Philippe; Janssens, Jean-Paul

    2012-02-01

    Current bilevel positive-pressure ventilators for home noninvasive ventilation (NIV) provide physicians with software that records items important for patient monitoring, such as compliance, tidal volume (Vt), and leaks. However, to our knowledge, the validity of this information has not yet been independently assessed. Testing was done for seven home ventilators on a bench model adapted to simulate NIV and generate unintentional leaks (ie, other than of the mask exhalation valve). Five levels of leaks were simulated using a computer-driven solenoid valve (0-60 L/min) at different levels of inspiratory pressure (15 and 25 cm H(2)O) and at a fixed expiratory pressure (5 cm H(2)O), for a total of 10 conditions. Bench data were compared with results retrieved from ventilator software for leaks and Vt. For assessing leaks, three of the devices tested were highly reliable, with a small bias (0.3-0.9 L/min), narrow limits of agreement (LA), and high correlations (R(2), 0.993-0.997) when comparing ventilator software and bench results; conversely, for four ventilators, bias ranged from -6.0 L/min to -25.9 L/min, exceeding -10 L/min for two devices, with wide LA and lower correlations (R(2), 0.70-0.98). Bias for leaks increased markedly with the importance of leaks in three devices. Vt was underestimated by all devices, and bias (range, 66-236 mL) increased with higher insufflation pressures. Only two devices had a bias ventilation must be aware of differences in the estimation of leaks and Vt by ventilator software. Also, leaks are reported in different ways according to the device used.

  7. Numerical modelling of orthogonal cutting: application to woodworking with a bench plane

    OpenAIRE

    Nairn, John A.

    2016-01-01

    A numerical model for orthogonal cutting using the material point method was applied to woodcutting using a bench plane. The cutting process was modelled by accounting for surface energy associated with wood fracture toughness for crack growth parallel to the grain. By using damping to deal with dynamic crack propagation and modelling all contact between wood and the plane, simulations could initiate chip formation and proceed into steady-state chip propagation including chip curling. Once st...

  8. Predicting the Maximum Dynamic Strength in Bench Press: The High Precision of the Bar Velocity Approach.

    Science.gov (United States)

    Loturco, Irineu; Kobal, Ronaldo; Moraes, José E; Kitamura, Katia; Cal Abad, César C; Pereira, Lucas A; Nakamura, Fábio Y

    2017-04-01

    Loturco, I, Kobal, R, Moraes, JE, Kitamura, K, Cal Abad, CC, Pereira, LA, and Nakamura, FY. Predicting the maximum dynamic strength in bench press: the high precision of the bar velocity approach. J Strength Cond Res 31(4): 1127-1131, 2017-The aim of this study was to determine the force-velocity relationship and test the possibility of determining the 1 repetition maximum (1RM) in "free weight" and Smith machine bench presses. Thirty-six male top-level athletes from 3 different sports were submitted to a standardized 1RM bench press assessment (free weight or Smith machine, in randomized order), following standard procedures encompassing lifts performed at 40-100% of 1RM. The mean propulsive velocity (MPV) was measured in all attempts. A linear regression was performed to establish the relationships between bar velocities and 1RM percentages. The actual and predicted 1RM for each exercise were compared using a paired t-test. Although the Smith machine 1RM was higher (10% difference) than the free weight 1RM, in both cases the actual and predicted values did not differ. In addition, the linear relationship between MPV and percentage of 1RM (coefficient of determination ≥95%) allow determination of training intensity based on the bar velocity. The linear relationships between the MPVs and the relative percentages of 1RM throughout the entire range of loads enable coaches to use the MPV to accurately monitor their athletes on a daily basis and accurately determine their actual 1RM without the need to perform standard maximum dynamic strength assessments.

  9. Acute effects of movement velocity on blood lactate and growth hormone responses after eccentric bench press exercise in resistance-trained men.

    Science.gov (United States)

    Calixto, Rd; Verlengia, R; Crisp, Ah; Carvalho, Tb; Crepaldi, Md; Pereira, Aa; Yamada, Ak; da Mota, Gr; Lopes, Cr

    2014-12-01

    This study aimed to compare the effects of different velocities of eccentric muscle actions on acute blood lactate and serum growth hormone (GH) concentrations following free weight bench press exercises performed by resistance-trained men. Sixteen healthy men were divided into two groups: slow eccentric velocity (SEV; n = 8) and fast eccentric velocity (FEV; n = 8). Both groups performed four sets of eight eccentric repetitions at an intensity of 70% of their one repetition maximum eccentric (1RMecc) test, with 2-minute rest intervals between sets. The eccentric velocity was controlled to 3 seconds per range of motion for SEV and 0.5 seconds for the FEV group. There was a significant difference (P bench press exercise in the SEV group (1.7 ± 0.6 ng · mL(-1)) relative to the FEV group (0.1 ± 0.0 ng · mL(-1)). In conclusion, the velocity of eccentric muscle action influences acute responses following bench press exercises performed by resistance-trained men using a slow velocity resulting in a greater metabolic stress and hormone response.

  10. Dynamics of water and nutrients for potted plants induced by flooded bench fertigation : experiments and simulation

    NARCIS (Netherlands)

    Otten, W.

    1994-01-01

    Dynamics of water and nutrients as affected by physical and chemical characteristics of a substrate, fertigation method and schedule, and plant uptake were studied for a flooded bench fertigation system for potted plants, through a detailed experimental study of the root environment and a

  11. Reliability Analysis of Traditional and Ballistic Bench Press Exercises at Different Loads.

    Science.gov (United States)

    García-Ramos, Amador; Padial, Paulino; García-Ramos, Miguel; Conde-Pipó, Javier; Argüelles-Cienfuegos, Javier; Štirn, Igor; Feriche, Belén

    2015-09-29

    The purpose of this study was to determine test-retest reliability for peak barbell velocity (Vpeak) during the bench press (BP) and bench press throw (BPT) exercises for loads corresponding to 20-70% of one-repetition maximum (1RM). Thirty physically active collegiate men conducted four evaluations after a preliminary BP 1RM determination (1RM·bw-1 = 1.02 ± 0.16 kg·kg-1). In counterbalanced order, participants performed two sessions of the BP in one week and two sessions of the BPT in another week. Recovery time between sessions within the same week was 48 hours and recovery time between sessions of different weeks was 120 hours. On each day of evaluation the individual load-velocity relationship at each tenth percentile (20-70% of 1RM) in a Smith machine for the BP or BPT was determined. Participants performed three attempts per load, but only the best repetition (highest Vpeak), registered by a linear position transducer, was analysed. The BPT resulted in a significantly lower coefficient of variation (CV) for the whole load-velocity relationship, compared to the BP (2.48% vs. 3.22%; p = 0.040). Test-retest intraclass correlation coefficients (ICCs) ranged from r = 0.94-0.85 for the BPT and r = 0.91-0.71 for the BP (p velocity.

  12. Relationships between Mechanical Variables in the Traditional and Close-Grip Bench Press.

    Science.gov (United States)

    Lockie, Robert G; Callaghan, Samuel J; Moreno, Matthew R; Risso, Fabrice G; Liu, Tricia M; Stage, Alyssa A; Birmingham-Babauta, Samantha A; Stokes, John J; Giuliano, Dominic V; Lazar, Adrina; Davis, DeShaun L; Orjalo, Ashley J

    2017-12-01

    The study aim was to determine relationships between mechanical variables in the one-repetition maximum (1RM) traditional bench press (TBP) and close-grip bench press (CGBP). Twenty resistance-trained men completed a TBP and CGBP 1RM. The TBP was performed with the preferred grip; the CGBP with a grip width of 95% biacromial distance. A linear position transducer measured: lift distance and duration; work; and peak and mean power, velocity, and force. Paired samples t-tests (p velocity was greater for the CGBP (d = 0.50-1.29). The 1RM TBP correlated with CGBP 1RM, power, and force (r = 0.685-0.982). TBP work correlated with CGBP 1RM, lift distance, power, force, and work (r = 0.542-0.931). TBP power correlated with CGBP 1RM, power, force, velocity, and work (r = 0.484-0.704). TBP peak and mean force related to CGBP 1RM, power, and force (r = 0.596-0.980). Due to relationships between the load, work, power, and force for the TBP and CGBP, the CGBP could provide similar strength adaptations to the TBP with long-term use. The velocity profile for the CGBP was different to that of the TBP. The CGBP could be used specifically to improve high-velocity, upper-body pushing movements.

  13. Development of an optical inspection bench for the inspection of internal surfaces of 650 MHz SCRF cavities

    International Nuclear Information System (INIS)

    Kokil, S.V.; Kane, G.V.; Raghavendra, S.; Chauhan, S.K.; Rajpoot, D.S.; Oraon, B.; Om Prakash; Joshi, S.C.

    2015-01-01

    An optical inspection system has been developed for inspection of internal surfaces of 650 MHz superconducting RF cavities. The cavity parts are welded either using Electron Beam or Laser Beam Welding for making a good quality of weld joints. Surface defects like pits, scratches, welding spatters etc. on the internal surface of the cavity deteriorates cavity performance. Surface quality of the cavity equator joint plays an important role in the cavity performance. To study the quality of equator surface, the inspection bench offers high resolution images with a linear resolution of 45 m/pixel at a distance of ∼200 mm. The bench comprises of two major sub-systems, optical imaging system and cavity positioning system. A digital camera and multi coloured illumination system is used to obtain high resolution images. The camera is mounted inside a long cylindrical tube. The cylindrical tube can be inserted into a SCRF cavity. The length of the cylinder is long enough to inspect five-cell 650 MHz SCRF cavity. The cavity is placed on a set of PTFE rollers, which are mounted on a trolley. The cavity can be moved linearly with the help of ball screw-servomotor mechanism. The camera along with cylindrical tube can be rotated around its axis with a stepper motor to scan the cavity's internal surface. The paper presents the details about the optical inspection bench and optical inspection results. (author)

  14. Effects of rest interval length on Smith machine bench press performance and perceived exertion in trained men.

    Science.gov (United States)

    Tibana, Ramires A; Vieira, Denis C L; Tajra, Vitor; Bottaro, Martim; de Salles, Belmiro F; Willardson, Jeffrey M; Prestes, Jonato

    2013-12-01

    This study compared two different rest intervals (RI) between sets of resistance exercise. Ten resistance-trained men (M age = 24.3, SD = 3.5 yr.; M weigh t= 80.0 kg, SD = 15.3; M height = 1.75 m, SD = 0.04) performed five sets of Smith machine bench presses at 60% of one repetition maximum, either with 1.5 min. or 3 min. RI between sets. Their repetition performance, total training volume, velocity, fatigue, rating of perceived exertion, and muscular power were measured. All of these measures indicated that performance was significantly better and fatigue was significantly lower in the 3 min. RI as compared with the 1.5 min. RI, except the rating of perceived exertion which did not show a significant difference. A longer RI between sets promotes superior performance for the bench press.

  15. Utilization of institutional delivery service and associated factors in Bench Maji zone, Southwest Ethiopia: community based, cross sectional study.

    Science.gov (United States)

    Tadele, Niguse; Lamaro, Tafesse

    2017-02-01

    At the end of Millennium development goals, Ethiopia was included among 10 countries which constitutes about 59% of maternal deaths due to complications of pregnancy and/or childbirth every year globally. Institutional delivery, which is believed to contribute in reduction of maternal mortality is still low. Hence this study was conducted in order to assess utilization of institutional delivery and related factors in Bench Maji zone, Southwest Ethiopia. Cross sectional study was employed from September 1st - 30th, 2015 in Bench Maji Zone, Southwest Ethiopia where 765 mothers who deliver 2 years preceding the study provided data for this research. Data were collected by enumerators who were trained. In addition to descriptive statistics, binary and multivariate logistic regression analyses were performed. Statistical significance was considered at a p-value delivery which was significant. In Bench Maji Zone institutional delivery was shown to be comparatively good compared to other studies in the region and in Ethiopia in general even though it is below the health sector transformation plan of Ethiopia which aimed to increase deliveries attended by skilled health personnel to 95%. Empowering women, increasing awareness about institutional delivery and proper scaling up of antenatal care services which is an entry point for institutional delivery are recommended.

  16. Medical immunology: two-way bridge connecting bench and bedside.

    Science.gov (United States)

    Rijkers, Ger T; Damoiseaux, Jan G M C; Hooijkaas, Herbert

    2014-12-01

    Medical immunology in The Netherlands is a laboratory specialism dealing with immunological analyses as well as pre- and post-analytical consultation to clinicians (clinical immunologists and other specialists) involved in patients with immune mediated diseases. The scope of medical immunology includes immunodeficiencies, autoimmune diseases, allergy, transfusion and transplantation immunology, and lymphoproliferative disorders plus the monitoring of these patients. The training, professional criteria, quality control of procedures and laboratories is well organized. As examples of the bridge function of medical immunology between laboratory (bench) and patient (bedside) the contribution of medical immunologists to diagnosis and treatment of primary immunodeficiency diseases (in particular: humoral immunodeficiencies) as well as autoantibodies (anti-citrullinated proteins in rheumatoid arthritis) are given. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Dynamic MTF, an innovative test bench for detector characterization

    Science.gov (United States)

    Emmanuel, Rossi; Raphaël, Lardière; Delmonte, Stephane

    2017-11-01

    PLEIADES HR are High Resolution satellites for Earth observation. Placed at 695km they reach a 0.7m spatial resolution. To allow such performances, the detectors are working in a TDI mode (Time and Delay Integration) which consists in a continuous charge transfer from one line to the consecutive one while the image is passing on the detector. The spatial resolution, one of the most important parameter to test, is characterized by the MTF (Modulation Transfer Function). Usually, detectors are tested in a staring mode. For a higher level of performances assessment, a dedicated bench has been set-up, allowing detectors' MTF characterization in the TDI mode. Accuracy and reproducibility are impressive, opening the door to new perspectives in term of HR imaging systems testing.

  18. Accumulation of uranium, cesium, and radium by microbial cells: bench-scale studies

    International Nuclear Information System (INIS)

    Strandberg, G.W.; Shumate, S.E. II.

    1982-07-01

    This report describes bench-scale studies on the utilization of microbial cells for the concentration and removal of uranium, radium, and cesium from nuclear processing waste streams. Included are studies aimed at elucidating the basic mechanism of uranium uptake, process development efforts for the use of a combined denitrification-uranium removal process to treat a specific nuclear processing waste stream, and a preliminary investigation of the applicability of microorganisms for the removal of 137 Cs and 226 Ra from existing waste solutions

  19. A bench-top automated workstation for nucleic acid isolation from clinical sample types.

    Science.gov (United States)

    Thakore, Nitu; Garber, Steve; Bueno, Arial; Qu, Peter; Norville, Ryan; Villanueva, Michael; Chandler, Darrell P; Holmberg, Rebecca; Cooney, Christopher G

    2018-04-18

    Systems that automate extraction of nucleic acid from cells or viruses in complex clinical matrices have tremendous value even in the absence of an integrated downstream detector. We describe our bench-top automated workstation that integrates our previously-reported extraction method - TruTip - with our newly-developed mechanical lysis method. This is the first report of this method for homogenizing viscous and heterogeneous samples and lysing difficult-to-disrupt cells using "MagVor": a rotating magnet that rotates a miniature stir disk amidst glass beads confined inside of a disposable tube. Using this system, we demonstrate automated nucleic acid extraction from methicillin-resistant Staphylococcus aureus (MRSA) in nasopharyngeal aspirate (NPA), influenza A in nasopharyngeal swabs (NPS), human genomic DNA from whole blood, and Mycobacterium tuberculosis in NPA. The automated workstation yields nucleic acid with comparable extraction efficiency to manual protocols, which include commercially-available Qiagen spin column kits, across each of these sample types. This work expands the scope of applications beyond previous reports of TruTip to include difficult-to-disrupt cell types and automates the process, including a method for removal of organics, inside a compact bench-top workstation. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. BENCH-SCALE STEAM REFORMING OF ACTUAL TANK 48H WASTE

    International Nuclear Information System (INIS)

    Burket, P; Gene Daniel, G; Charles Nash, C; Carol Jantzen, C; Michael Williams, M

    2008-01-01

    Fluidized Bed Steam Reforming (FBSR) has been demonstrated to be a viable technology to remove >99% of the organics from Tank 48H simulant, to remove >99% of the nitrate/nitrite from Tank 48H simulant, and to form a solid product that is primarily carbonate based. The technology was demonstrated in October of 2006 in the Engineering Scale Test Demonstration Fluidized Bed Steam Reformer1 (ESTD FBSR) at the Hazen Research Inc. (HRI) facility in Golden, CO. The purpose of the Bench-scale Steam Reformer (BSR) testing was to demonstrate that the same reactions occur and the same product is formed when steam reforming actual radioactive Tank 48H waste. The approach used in the current study was to test the BSR with the same Tank 48H simulant and same Erwin coal as was used at the ESTD FBSR under the same operating conditions. This comparison would allow verification that the same chemical reactions occur in both the BSR and ESTD FBSR. Then, actual radioactive Tank 48H material would be steam reformed in the BSR to verify that the actual tank 48H sample reacts the same way chemically as the simulant Tank 48H material. The conclusions from the BSR study and comparison to the ESTD FBSR are the following: (1) A Bench-scale Steam Reforming (BSR) unit was successfully designed and built that: (a) Emulated the chemistry of the ESTD FBSR Denitration Mineralization Reformer (DMR) and Carbon Reduction Reformer (CRR) known collectively as the dual reformer flowsheet. (b) Measured and controlled the off-gas stream. (c) Processed real (radioactive) Tank 48H waste. (d) Met the standards and specifications for radiological testing in the Savannah River National Laboratory (SRNL) Shielded Cells Facility (SCF). (2) Three runs with radioactive Tank 48H material were performed. (3) The Tetraphenylborate (TPB) was destroyed to > 99% for all radioactive Bench-scale tests. (4) The feed nitrate/nitrite was destroyed to >99% for all radioactive BSR tests the same as the ESTD FBSR. (5) The

  1. BENCH-SCALE STEAM REFORMING OF ACTUAL TANK 48H WASTE

    Energy Technology Data Exchange (ETDEWEB)

    Burket, P; Gene Daniel, G; Charles Nash, C; Carol Jantzen, C; Michael Williams, M

    2008-09-25

    Fluidized Bed Steam Reforming (FBSR) has been demonstrated to be a viable technology to remove >99% of the organics from Tank 48H simulant, to remove >99% of the nitrate/nitrite from Tank 48H simulant, and to form a solid product that is primarily carbonate based. The technology was demonstrated in October of 2006 in the Engineering Scale Test Demonstration Fluidized Bed Steam Reformer1 (ESTD FBSR) at the Hazen Research Inc. (HRI) facility in Golden, CO. The purpose of the Bench-scale Steam Reformer (BSR) testing was to demonstrate that the same reactions occur and the same product is formed when steam reforming actual radioactive Tank 48H waste. The approach used in the current study was to test the BSR with the same Tank 48H simulant and same Erwin coal as was used at the ESTD FBSR under the same operating conditions. This comparison would allow verification that the same chemical reactions occur in both the BSR and ESTD FBSR. Then, actual radioactive Tank 48H material would be steam reformed in the BSR to verify that the actual tank 48H sample reacts the same way chemically as the simulant Tank 48H material. The conclusions from the BSR study and comparison to the ESTD FBSR are the following: (1) A Bench-scale Steam Reforming (BSR) unit was successfully designed and built that: (a) Emulated the chemistry of the ESTD FBSR Denitration Mineralization Reformer (DMR) and Carbon Reduction Reformer (CRR) known collectively as the dual reformer flowsheet. (b) Measured and controlled the off-gas stream. (c) Processed real (radioactive) Tank 48H waste. (d) Met the standards and specifications for radiological testing in the Savannah River National Laboratory (SRNL) Shielded Cells Facility (SCF). (2) Three runs with radioactive Tank 48H material were performed. (3) The Tetraphenylborate (TPB) was destroyed to > 99% for all radioactive Bench-scale tests. (4) The feed nitrate/nitrite was destroyed to >99% for all radioactive BSR tests the same as the ESTD FBSR. (5) The

  2. Towards micro-assembly of hybrid MOEMS components on a reconfigurable silicon free-space micro-optical bench

    International Nuclear Information System (INIS)

    Bargiel, S; Gorecki, C; Rabenorosoa, K; Clévy, C; Lutz, P

    2010-01-01

    The 3D integration of hybrid chips is a viable approach for the micro-optical technologies to reduce the costs of assembly and packaging. In this paper a technology platform for the hybrid integration of MOEMS components on a reconfigurable silicon free-space micro-optical bench (FS-MOB) is presented. In this approach a desired optical component (e.g. micromirror, microlens) is integrated with a removable and adjustable silicon holder which can be manipulated, aligned and fixed in the precisely etched rail of the silicon baseplate by use of a robotic micro-assembly station. An active-based gripping system allows modification of the holder position on the baseplate with nanometre precision. The fabrication processes of the micromachined parts of the micro-optical bench, based on bulk micromachining of standard silicon wafer and SOI wafer, are described. The successful assembly of the holders, equipped with a micromirror and a refractive glass ball microlens, on the baseplate rail is demonstrated.

  3. Results of a bench mark test on the crack opening and leak rate calculation

    International Nuclear Information System (INIS)

    Grebner, H.

    1995-01-01

    Results of a bench mark test on the standard problem calculation of crack opening and leak rate in piping components are presented. The bench mark test is based on two experiments performed in phase III of the German HDR safety program. The pipe sections considered in these experiments were a straight pipe with an 80 mm diameter containing a circumferential wall penetrating crack and a pipe branch DN 100/DN 25 with a crack in the weldment between the nozzle and the main pipe. Both test pieces were made of austenitic steel and were loaded by internal pressure and bending moment. For the evaluation of the crack opening either analytical methods or estimation schemes or the finite element method were used, while leak rates were calculated by means of two-phase flow methods. The compilation of the results shows very large scatter bands in general, with deviations between calculated and measured values of up to some one hundred percent. Reasons for this behaviour are uncertainties in the measured data and their evaluation as well as the different methods of calculation and their uncertainties. (author)

  4. Modification of a compressor performance test bench for liquid slugging observation in refrigeration compressors

    Science.gov (United States)

    Ola, Max; Thomas, Christiane; Hesse, Ullrich

    2017-08-01

    Compressor performance test procedures are defined by the standard DIN EN 13771, wherein a variety of possible calorimeter and flow rate measurement methods are suggested. One option is the selection of two independent measurement methods. The accuracies of both selected measurement methods are essential. The second option requires only one method. However the measurement accuracy of the used device has to be verified and recalibrated on a regular basis. The compressor performance test facility at the Technische Universitaet Dresden uses a calibrated flow measurement sensor, a hot gas bypass and a mixed flow heat exchanger. The test bench can easily be modified for tests of various compressor types at different operating ranges and with various refrigerants. In addition, the modified test setup enables the investigation of long term liquid slug and its effects on the compressor. The modification comprises observational components, adjustments of the control system, safety measures and a customized oil recirculation system for compressors which do not contain an integrated oil sump or oil level regulation system. This paper describes the setup of the test bench, its functional principle, the key modifications, first test results and an evaluation of the energy balance.

  5. Effect of Different Interrepetition Rest Periods on Barbell Velocity Loss During the Ballistic Bench Press Exercise.

    Science.gov (United States)

    García-Ramos, Amador; Padial, Paulino; Haff, G Gregory; Argüelles-Cienfuegos, Javier; García-Ramos, Miguel; Conde-Pipó, Javier; Feriche, Belén

    2015-09-01

    This study investigated the effect of introducing different interrepetition rest (IRR) periods on the ability to sustain maximum bench press throw velocity with a range of loads commonly used to develop upper-body power. Thirty-four physically active collegiate men (age: 21.5 ± 2.8 years; body mass: 75.2 ± 7.2 kg; height: 176.9 ± 4.9 cm) were tested during 2 consecutive weeks. During the first week, the maximum dynamic strength (repetition maximum [RM]) in bench press exercise was determined (RM = 76.7 ± 13.2 kg). The following week, 3 testing sessions were conducted with 48 hours apart in random order. In each day of evaluation, only 1 load (30%RM, 40%RM, or 50%RM) was assessed in the bench press throw exercise. With each load, subjects performed 3 single sets of 15 repetitions (15-minute interset rest) with 3 different sets configurations: continuous repetitions (CR), 6 seconds of IRR (IRR6), and 12 seconds of IRR (IRR12). The decrease of peak velocity (PV) was significantly lower for IRR12 compared with CR and IRR6 at least since the repetition 4. No differences between CR and IRR6 protocols were found until the repetition 7 at 30%RM and 40%RM and until the repetition 5 at 50%RM. The decrease of PV during the CR protocol was virtually linear for the 3 loads analyzed (r > 0.99); however, this linear relationship became weaker for IRR6 (r = 0.79-0.95) and IRR12 (r = 0.35-0.87). These results demonstrate that IRR periods allow increasing the number of repetitions before the onset of significant velocity losses.

  6. A novel bench-scale column assay to investigate site-specific nitrification biokinetics in biological rapid sand filters

    DEFF Research Database (Denmark)

    Tatari, Karolina; Smets, Barth F.; Albrechtsen, Hans-Jørgen

    2013-01-01

    A bench-scale assay was developed to obtain site-specific nitrification biokinetic information from biological rapid sand filters employed in groundwater treatment. The experimental set-up uses granular material subsampled from a full-scale filter, packed in a column, and operated with controlled...

  7. Presence of Spotters Improves Bench Press Performance: A Deception Study.

    Science.gov (United States)

    Sheridan, Andrew; Marchant, David C; Williams, Emily L; Jones, Hollie S; Hewitt, Phil A; Sparks, S Andy

    2017-10-24

    Sheridan, A, Marchant, DC, Williams, EL, Jones, HS, Hewitt, PA, and Sparks, SA. Presence of spotters improves bench press performance: a deception study. J Strength Cond Res XX(X): 000-000, 2017-Resistance exercise is a widely used method of physical training in both recreational exercise and athletic populations. The use of training partners and spotters during resistance exercise is widespread, but little is known about the effect of the presence of these individuals on exercise performance. The purpose of the current study was to investigate the effect of spotter presence on bench press performance. Twelve recreationally trained participants (age, 21.3 ± 0.8 years, height, 1.82 ± 0.1 m, and weight, 84.8 ± 11.1 kg) performed 2 trials of 3 sets to failure at 60% of 1 repetition maximum on separate occasions. The 2 trials consisted of spotters being explicitly present or hidden from view (deception). During the trials, total repetitions (reps), total weight lifted, ratings of perceived exertion (RPE), and self-efficacy were measured. Total reps and weight lifted were significantly greater with spotters (difference = 4.5 reps, t = 5.68, p < 0.001 and difference = 209.6 kg, t = 5.65, p < 0.001, respectively). Although RPE and local RPE were significantly elevated in the deception trials (difference = 0.78, f = 6.16, p = 0.030 and difference = 0.81, f = 5.89, p = 0.034, respectively), self-efficacy was significantly reduced (difference = 1.58, f = 26.90, p < 0.001). This study demonstrates that resistance exercise is improved by the presence of spotters, which is facilitated by reduced RPE and increased self-efficacy. This has important implications for athletes and clients, who should perform resistance exercise in the proximity of others, to maximize total work performed.

  8. LiveBench-1: continuous benchmarking of protein structure prediction servers.

    Science.gov (United States)

    Bujnicki, J M; Elofsson, A; Fischer, D; Rychlewski, L

    2001-02-01

    We present a novel, continuous approach aimed at the large-scale assessment of the performance of available fold-recognition servers. Six popular servers were investigated: PDB-Blast, FFAS, T98-lib, GenTHREADER, 3D-PSSM, and INBGU. The assessment was conducted using as prediction targets a large number of selected protein structures released from October 1999 to April 2000. A target was selected if its sequence showed no significant similarity to any of the proteins previously available in the structural database. Overall, the servers were able to produce structurally similar models for one-half of the targets, but significantly accurate sequence-structure alignments were produced for only one-third of the targets. We further classified the targets into two sets: easy and hard. We found that all servers were able to find the correct answer for the vast majority of the easy targets if a structurally similar fold was present in the server's fold libraries. However, among the hard targets--where standard methods such as PSI-BLAST fail--the most sensitive fold-recognition servers were able to produce similar models for only 40% of the cases, half of which had a significantly accurate sequence-structure alignment. Among the hard targets, the presence of updated libraries appeared to be less critical for the ranking. An "ideally combined consensus" prediction, where the results of all servers are considered, would increase the percentage of correct assignments by 50%. Each server had a number of cases with a correct assignment, where the assignments of all the other servers were wrong. This emphasizes the benefits of considering more than one server in difficult prediction tasks. The LiveBench program (http://BioInfo.PL/LiveBench) is being continued, and all interested developers are cordially invited to join.

  9. Study of ignition, combustion, and production of harmful substances upon burning solid organic fuel at a test bench with a vortex chamber

    Science.gov (United States)

    Burdukov, A. P.; Chernetskiy, M. Yu.; Dekterev, A. A.; Anufriev, I. S.; Strizhak, P. A.; Greben'kov, P. Yu.

    2016-01-01

    Results of investigation of furnace processes upon burning of pulverized fuel at a test bench with a power of 5 MW are presented. The test bench consists of two stages with tangential air and pulverized coal feed, and it is equipped by a vibrocentrifugal mill and a disintegrator. Such milling devices have an intensive mechanical impact on solid organic fuel, which, in a number of cases, increases the reactivity of ground material. The processes of ignition and stable combustion of a mixture of gas coal and sludge (wastes of concentration plant), as well as Ekibastus coal, ground in the disintegrator, were studied at the test bench. The results of experimental burning demonstrated that preliminary fuel grinding in the disintegrator provides autothermal combustion mode even for hardly inflammable organic fuels. Experimental combustion of biomass, wheat straw with different lignin content (18, 30, 60%) after grinding in the disintegrator, was performed at the test bench in order to determine the possibility of supporting stable autothermal burning. Stable biofuel combustion mode without lighting by highly reactive fuel was achieved in the experiments. The influence of the additive GTS-Powder (L.O.M. Leaders Co., Ltd., Republic of Korea) in the solid and liquid state on reducing sulfur oxide production upon burning Mugun coal was studied. The results of experimental combustion testify that, for an additive concentration from 1 to 15% of the total mass of the burned mixture, the maximum SO2 concentration reduction in ejected gases was not more than 18% with respect to the amount for the case of burning pure coal.

  10. A Study on introduction of Bench Marking in the power industry - concentrated on the Bench Marking issue in the power industry

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Hyuck Soo [Korea Energy Economics Institute, Euiwang (Korea)

    1998-08-01

    Recently it takes too much pains for enterprises to be adapted to the more complicated social structure. There are no guarantees to survive in competition only with improving service quality of a product, reducing cost by improving production efficiency, and reducing labors. To survive in a keen competition, it is important to acquire new management techniques and management theories. Among them, a benchmarking technique, improving competitive power through the analysis of top-ranking companies or companies with excellent results in a comparative sector, is in the spotlight recently. Therefore, the approaches to bench marking were discussed with the focus on the adaptation of KEPCO with a new paradigm. However, this study contained the limit of applying benchmarking technique due to its huge scale. Therefore, it was focused on brining up benchmarking issue by reflecting the basic problems of power industry to the developed countries. (author). 29 refs., 16 figs., 41 tabs.

  11. Bench- and field-scale evaluation of chromium and cadmium extraction by electrokinetics

    International Nuclear Information System (INIS)

    Gent, David B.; Bricka, R. Mark; Alshawabkeh, Akram N.; Larson, Steven L.; Fabian, Gene; Granade, Steve

    2004-01-01

    The results of bench-scale laboratory tests and in situ, pilot-scale demonstration of electrokinetic extraction of chromium and cadmium from contaminated soil are presented. The laboratory tests were conducted using 10 cm long samples under current density of 5 A/m 2 for 1200 h. Tests were conducted with and without citric acid amendment at the cathode. The results showed that citric acid improved extraction, especially in the sections near the cathode. However, processing was not enough to result in complete cleanup. The field demo was conducted at the Naval Air Weapon Station (NAWS), Point Mugu, California. Three cathodes were centered between six anodes. The anode-cathode spacing was 4.45 m (15 ft). Constant voltage of 60 V (∼13 V/m) was applied for 20 days and then was reduced to 45 V (10 V/m) for 6 months. Citric acid was used to maintain the cathode pH at 4. After 6 months of treatment, 78% of the soil volume has been cleared of chromium or treated to below natural background levels. The results also indicated that 70% of the soil between the electrodes had been cleared of cadmium contamination. A comparison between the bench-scale and field demo showed that the field process was more effective than the lab tests. This indicated that small sample size will induce a negative effect on the efficiency of the process due to an increased impact of the boundaries on the overall process

  12. Dissociated time course between peak torque and total work recovery following bench press training in resistance trained men.

    Science.gov (United States)

    Ferreira, Diogo V; Gentil, Paulo; Ferreira-Junior, João B; Soares, Saulo R S; Brown, Lee E; Bottaro, Martim

    2017-10-01

    To evaluate the time course of peak torque and total work recovery after a resistance training session involving the bench press exercise. Repeated measures with a within subject design. Twenty-six resistance-trained men (age: 23.7±3.7years; height: 176.0±5.7cm; mass: 79.65±7.61kg) performed one session involving eight sets of the bench press exercise performed to momentary muscle failure with 2-min rest between sets. Shoulder horizontal adductors peak torque (PT), total work (TW), delayed onset muscle soreness (DOMS) and subjective physical fitness were measured pre, immediately post, 24, 48, 72 and 96h following exercise. The exercise protocol resulted in significant pectoralis major DOMS that lasted for 72h. Immediately after exercise, the reduction in shoulder horizontal adductors TW (25%) was greater than PT (17%). TW, as a percentage of baseline values, was also less than PT at 24, 48 and 96h after exercise. Additionally, PT returned to baseline at 96h, while TW did not. Resistance trained men presented dissimilar PT and TW recovery following free weight bench press exercise. This indicates that recovery of maximal voluntary contraction does not reflect the capability to perform multiple contractions. Strength and conditioning professionals should be cautious when evaluating muscle recovery by peak torque, since it can lead to the repetition of a training session sooner than recommended. Copyright © 2017. Published by Elsevier Inc.

  13. Analytical Method for Carbon and Oxygen Isotope of Small Carbonate Samples with the GasBench Ⅱ-IRMS Device

    Directory of Open Access Journals (Sweden)

    LIANG Cui-cui

    2015-01-01

    Full Text Available An analytical method for measuring carbon and oxygen isotopic compositions of trace amount carbonate (>15 μg was established by Delta V Advantage isotope Ratio MS coupled with GasBench Ⅱ. Different trace amount (5-50 μg carbonate standard samples (IAEA-CO-1 were measured by GasBench Ⅱ with 12 mL and 3.7 mL vials. When the weight of samples was less than 40 μg and it was acidified in 12 mL vials, most standard deviations of the δ13C and δ18O were more than 0.1‰, which couldn’t satisfied high-precision measurements. When the weight of samples was greater than 15 μg and it was acidified in 3.7 mL vials, standard deviations for the δ13C and δ18O were 0.01‰-0.07‰ and 0.01‰-0.08‰ respectively, which satisfied high-precision measurements. Therefore, small 3.7 mL vials were used to increase the concentration of carbon dioxide in headspace, carbonate samples even less as 15 μg can be analyzed routinely by a GasBench Ⅱ continuous-flow IRMS. Meanwhile, the linear relationship between sample’s weight and peak’s area was strong (R2>0.993 2 and it can be used to determine the carbon content of carbonate samples.

  14. New pocket tools for Physics: create a star on one's laboratory bench

    International Nuclear Information System (INIS)

    Larousserie, D.

    2001-01-01

    Big science means huge investment in giant physics instruments like particle accelerators or fusion reactors. Today this way of making physics enters in competition with more bench-scale research, this research requires less financial means and then can be developed in university laboratories. This trend has been made possible by the recent technological progress in the field of power lasers. A source of X-radiation, similar to that obtained from a big synchrotron can be designed by using adequate lasers. Thermonuclear reactions have been recently produced in laser targets. (A.C.)

  15. Time course for arm and chest muscle thickness changes following bench press training

    Science.gov (United States)

    Ogasawara, Riki; Thiebaud, Robert S.; Loenneke, Jeremy P.; Loftin, Mark

    2012-01-01

    The purpose of this study was to investigate the time course of hypertrophic adaptations in both the upper arm and trunk muscles following high-intensity bench press training. Seven previously untrained young men (aged 25 ± 3 years) performed free-weight bench press training 3 days (Monday, Wednesday and Friday) per week for 24 weeks. Training intensity and volume were set at 75% of one repetition maximum (1-RM) and 30 repetitions (3 sets of 10 repetitions, with 2−3 min of rest between sets), respectively. Muscle thickness (MTH) was measured using B-mode ultrasound at three sites: the biceps and triceps brachii and the pectoralis major. Measurements were taken a week prior to the start of training, before the training session on every Monday and 3 days after the final training session. Pairwise comparisons from baseline revealed that pectoralis major MTH significantly increased after week-1 (p = 0.002), triceps MTH increased after week-5 (p = 0.001) and 1-RM strength increased after week-3 (p = 0.001) while no changes were observed in the biceps MTH from baseline. Significant muscle hypertrophy was observed earlier in the chest compared to that of the triceps. Our results indicate that the time course of the muscle hypertrophic response differs between the upper arm and chest. PMID:24265879

  16. Runoff and sediment generation on bench -terraced hillsides: measurements and up-scaling of a field-based model

    NARCIS (Netherlands)

    van Dijk, A.I.J.M.; Bruijnzeel, L.A.; Vertessy, R.A.; Ruijter, J.

    2006-01-01

    Despite widespread bench-terracing, stream sediment yields from agricultural hillsides in upland West Java remain high. We studied the causes of this lack of effect by combining measurements at different spatial scales using an erosion process model. Event runoff and sediment yield from two 4-ha

  17. From bench to bedside: use of human adipose-derived stem cells

    Directory of Open Access Journals (Sweden)

    Feisst V

    2015-11-01

    Full Text Available Vaughan Feisst,1 Sarah Meidinger,1 Michelle B Locke2 1Dunbar Laboratory, School of Biological Sciences, 2Department of Surgery, Faculty of Medicine and Health Sciences, The University of Auckland, Auckland, New Zealand Abstract: Since the discovery of adipose-derived stem cells (ASC in human adipose tissue nearly 15 years ago, significant advances have been made in progressing this promising cell therapy tool from the laboratory bench to bedside usage. Standardization of nomenclature around the different cell types used is finally being adopted, which facilitates comparison of results between research groups. In vitro studies have assessed the ability of ASC to undergo mesenchymal differentiation as well as differentiation along alternate lineages (transdifferentiation. Recently, focus has shifted to the immune modulatory and paracrine effects of transplanted ASC, with growing interest in the ASC secretome as a source of clinical effect. Bedside use of ASC is advancing alongside basic research. An increasing number of safety-focused Phase I and Phase IIb trials have been published without identifying any significant risks or adverse events in the short term. Phase III trials to assess efficacy are currently underway. In many countries, regulatory frameworks are being developed to monitor their use and assure their safety. As many trials rely on ASC injected at a distant site from the area of clinical need, strategies to improve the homing and efficacy of transplanted cells are also being explored. This review highlights each of these aspects of the bench-to-bedside use of ASC and summarizes their clinical utility across a variety of medical specialties. Keywords: standardization, bystander effect, stromal cells, mesenchymal stem cells, stromal vascular fraction

  18. Plans of mice and men: from bench science to science policy.

    Science.gov (United States)

    Simon, Ian D

    2011-09-01

    The transition from bench science to science policy is not always a smooth one, and my journey stretched as far as the unemployment line to the hallowed halls of the U.S. Capitol. While earning my doctorate in microbiology, I found myself more interested in my political activities than my experiments. Thus, my science policy career aspirations were born from merging my love of science with my interest in policy and politics. After receiving my doctorate, I accepted the Henry Luce Scholarship, which allowed me to live in South Korea for 1 year and delve into the field of science policy research. This introduction into science policy occurred at the South Korean think tank called the Science and Technology Policy Institute (STEPI). During that year, I used textbooks, colleagues, and hands-on research projects as my educational introduction into the social science of science and technology decision-making. However, upon returning to the United States during one of the worst job markets in nearly 80 years, securing a position in science policy proved to be very difficult, and I was unemployed for five months. Ultimately, it took more than a year from the end of the Luce Scholarship to obtain my next science policy position with the American Society for Microbiology Congressional Fellowship. This fellowship gave me the opportunity to work as the science and public health advisor to U.S. Senator Harry Reid. While there were significant challenges during my transition from the laboratory to science policy, those challenges made me tougher, more appreciative, and more prepared to move from working at the bench to working in the field of science policy. Copyright © 2011.

  19. The "sticking period" in a maximum bench press.

    Science.gov (United States)

    van den Tillaar, Roland; Ettema, Gertjan

    2010-03-01

    The purpose of this study was to examine muscle activity and three-dimensional kinematics in the ascending phase of a successful one-repetition maximum attempt in bench press for 12 recreational weight-training athletes, with special attention to the sticking period. The sticking period was defined as the first period of deceleration of the upward movement (i.e. from the highest barbell velocity until the first local lowest barbell velocity). All participants showed a sticking period during the upward movement that started about 0.2 s after the initial upward movement, and lasted about 0.9 s. Electromyography revealed that the muscle activity of the prime movers changed significantly from the pre-sticking to the sticking and post-sticking periods. A possible mechanism for the existence of the sticking period is the diminishing potentiation of the contractile elements during the upward movement together with the limited activity of the pectoral and deltoid muscles during this period.

  20. An Integration of Geophysical Methods to Explore Buried Structures on the Bench and in the Field

    Science.gov (United States)

    Booterbaugh, A. P.; Lachhab, A.

    2011-12-01

    In the following study, an integration of geophysical methods and devices were implemented on the bench and in the field to accurately identify buried structures. Electrical resistivity and ground penetrating radar methods, including both a fabricated electrical resistivity apparatus and an electrical resistivity device were all used in this study. The primary goal of the study was to test the accuracy and reliability of the apparatus which costs a fraction of the price of a commercially sold resistivity instrument. The apparatus consists of four electrodes, two multimeters, a 12-volt battery, a DC to AC inverter and wires. Using this apparatus, an electrical current, is injected into earth material through the outer electrodes and the potential voltage is measured across the inner electrodes using a multimeter. The recorded potential and the intensity of the current can then be used to calculate the apparent resistivity of a given material. In this study the Wenner array, which consists of four equally spaced electrodes, was used due to its higher accuracy and greater resolution when investigating lateral variations of resistivity in shallow depths. In addition, the apparatus was used with an electrical resistivity device and a ground penetrating radar unit to explore the buried building foundation of Gustavus Adolphus Hall located on Susquehanna University Campus, Selinsgrove, PA. The apparatus successfully produced consistent results on the bench level revealing the location of small bricks buried under a soil material. In the summer of 2010, seventeen electrical resistivity transects were conducted on the Gustavus Adolphus site where and revealed remnants of the foundation. In the summer of 2011, a ground penetrating radar survey and an electrical resistivity tomography survey were conducted to further explore the site. Together these methods identified the location of the foundation and proved that the apparatus was a reliable tool for regular use on the bench

  1. Benchmarking network for clinical and humanistic outcomes in diabetes (BENCH-D) study: protocol, tools, and population.

    Science.gov (United States)

    Nicolucci, Antonio; Rossi, Maria C; Pellegrini, Fabio; Lucisano, Giuseppe; Pintaudi, Basilio; Gentile, Sandro; Marra, Giampiero; Skovlund, Soren E; Vespasiani, Giacomo

    2014-01-01

    In the context of the DAWN-2 initiatives, the BENCH-D Study aims to test a model of regional benchmarking to improve not only the quality of diabetes care, but also patient-centred outcomes. As part of the AMD-Annals quality improvement program, 32 diabetes clinics in 4 Italian regions extracted clinical data from electronic databases for measuring process and outcome quality indicators. A random sample of patients with type 2 diabetes filled in a questionnaire including validated instruments to assess patient-centred indicators: SF-12 Health Survey, WHO-5 Well-Being Index, Diabetes Empowerment Scale, Problem Areas in Diabetes, Health Care Climate Questionnaire, Patients Assessment of Chronic Illness Care, Barriers to Medications, Patient Support, Diabetes Self-care Activities, and Global Satisfaction for Diabetes Treatment. Data were discussed with participants in regional meetings. Main problems, obstacles and solutions were identified through a standardized process, and a regional mandate was produced to drive the priority actions. Overall, clinical indicators on 78,854 patients have been measured; additionally, 2,390 patients filled-in the questionnaire. The regional mandates were officially launched in March 2012. Clinical and patient-centred indicators will be evaluated again after 18 months. A final assessment of clinical indicators will take place after 30 months. In the context of the BENCH-D study, a set of instruments has been validated to measure patient well-being and satisfaction with the care. In the four regional meetings, different priorities were identified, reflecting different organizational resources of the different areas. In all the regions, a major challenge was represented by the need of skills and instruments to address psychosocial issues of people with diabetes. The BENCH-D study allows a field testing of benchmarking activities focused on clinical and patient-centred indicators.

  2. Optimal Velocity to Achieve Maximum Power Output – Bench Press for Trained Footballers

    OpenAIRE

    Richard Billich; Jakub Štvrtňa; Karel Jelen

    2015-01-01

    Optimal Velocity to Achieve Maximum Power Output – Bench Press for Trained Footballers In today’s world of strength training there are many myths surrounding effective exercising with the least possible negative effect on one’s health. In this experiment we focus on the finding of a relationship between maximum output, used load and the velocity with which the exercise is performed. The main objective is to find the optimal speed of the exercise motion which would allow us to reach the ma...

  3. Bench test results on a new technique for far-infrared polarimetry

    International Nuclear Information System (INIS)

    Barry, S.; Nieswand, C.; Prunty, S.L.; Mansfield, H.M.; O'Leary, P.

    1996-11-01

    The results of bench tests performed on a new method of combined interferometry/polarimetry for the magnetic field reconstruction of tokamak plasmas is presented. In particular, the sensitivity obtained in the polarimetric measurement shows the feasibility of Faraday rotation determination approaching a precision of ±0.2 o . The method is based on an optically pumped far-infrared (FIR) laser with a rotating polarization where both the interferometric and polarimetric information is determined from phase measurements. Specific sources which introduce disturbances in the optical arrangement and which can limit the attainment of the polarimetric precision, mentioned above, are discussed. (author) 4 figs., 6 refs

  4. Terrace erosion and sediment transport model: a new tool for soil conservation planning in bench-terraced steeplands.

    NARCIS (Netherlands)

    van Dijk, A.I.J.M.; Bruijnzeel, L.A.

    2003-01-01

    Despite widespread bench-terracing soil erosion remains a major problem in Java's uplands. To elucidate the causes for this lack of impact, runoff and erosion processes were studied at a variety of spatial scales within a volcanic catchment in West Java. Research indicated that soil loss occurs via

  5. BWR Mark I pressure suppression study: characterization of the vertical load function utilizing bench top model tests

    International Nuclear Information System (INIS)

    McCauley, E.W.; Lai, W.

    1977-02-01

    A study was conducted to characterize the mechanisms which give rise to observed oscillations in the vertical load function (VLF) of bench top pool dynamics tests. This is part of a continuing investigation at the Lawrence Livermore Laboratory of the General Electric Mark I Nuclear Reactor pressure suppression system

  6. Between the bench, the bedside and the office: The need to build bridges between working neuroscientists and ethicists.

    Science.gov (United States)

    Brosnan, Caragh; Cribb, Alan

    2014-12-01

    This paper presents findings from an empirical study that explored the meaning of ethics in the everyday work of neuroscientists. Observation and interviews were carried out in one neuroscience research group that was involved in bench-to-bedside translational research. We focus here specifically on the scientists' perceptions of bioethics. Interviewees were often unfamiliar with bioethics as a discipline, particularly the more junior members of the group. Those who were aware of its existence largely viewed it as something distant from them, and as either too abstract, not relevant or an alien imposition on their work. Some interviewees themselves pointed to the need for better 'bridge building' between ethical principles and real-world examples drawn from scientific practice, and we argue that this space is where a more empirically grounded ethics may be useful in terms of actually engaging scientists at both the bench and the bedside.

  7. The R and D D`s bearing test benches; Les bancs d`essais de paliers de la DER

    Energy Technology Data Exchange (ETDEWEB)

    Vialettes, J.M. [Service Ensembles de Production, Departement Machines, Direction des Etudes et Recherches, Electricite de France (EDF), 92 - Clamart (France)

    1997-01-01

    In power generation plants, rotating machines are involved in energy transformation processes and safety systems. The bearings supporting the rotors and the thrust bearings play a crucial role in the reliability of these machines. The phenomena encountered straddle several disciplines: hydrodynamics, tribology, thermomechanics, materials and vibrations in a specific environment, namely: thin fluid film, solid mechanical components and shaft rotation. Means of analysing the behaviour of these components (bearings and thrust bearings) have been developed and implemented. These consists of the EDYOS (Etude Dynamique des Organes de Supportage) code for dynamically studying bearing devices and several related bench tests. In reality, in order to understand the complex physical phenomena encountered in these components, it is vital to carry out analyses and experimental validations. Since these investigations cannot be carried out on actual machines, test benches have been built which can subject the sample bearings to the equivalent stresses. (author) 14 figs.

  8. Old star clusters: Bench tests of low mass stellar models

    Directory of Open Access Journals (Sweden)

    Salaris M.

    2013-03-01

    Full Text Available Old star clusters in the Milky Way and external galaxies have been (and still are traditionally used to constrain the age of the universe and the timescales of galaxy formation. A parallel avenue of old star cluster research considers these objects as bench tests of low-mass stellar models. This short review will highlight some recent tests of stellar evolution models that make use of photometric and spectroscopic observations of resolved old star clusters. In some cases these tests have pointed to additional physical processes efficient in low-mass stars, that are not routinely included in model computations. Moreover, recent results from the Kepler mission about the old open cluster NGC6791 are adding new tight constraints to the models.

  9. International interest in the BONAPARTE measurement bench. Post-irradiation examination of lower-enriched fuel plates

    International Nuclear Information System (INIS)

    2014-01-01

    The Belgian Nuclear Research Center SCK-CEN has developed a measurement bench (BONAPARTE) for the non-destructive analysis on fuel plate and rod type fuel elements. BONAPARTE is a modular device that can be employed for many purposes. The article discusses the employment of the BONAPARTE device for the accurate full post-irradiation mapping of fuel plate swelling with degree of precision of just a few micrometers.

  10. Description and evaluation of a bench porcine model for teaching surgical residents vascular anastomosis skills

    Directory of Open Access Journals (Sweden)

    Jauch Karl-Walter

    2010-07-01

    Full Text Available Abstract Background Numerous models, of variable quality, exist to impart the complex skills required to perform vascular anastomosis. These models differ with regard to the kinds of materials used, as well as their sizes, the time needed for their preparation, their availability, and the associated costs. The present study describes a bench model that uses formalin-fixed porcine aorta, and its evaluation by young surgical residents during a recent skills course. Findings The aortic segments used were a by-product of slaughtering. They were fixed and stored after harvesting for eventual use. Ten young surgical residents participated, and each performed one end-to-side vascular anastomosis. The evaluation was a questionnaire maintaining anonymity of the participant containing questions addressing particular aspects of the model and the experiences of the trainee, along with their ratings concerning the need for a training course to learn vascular anastomosis techniques. The scoring on the survey was done using a global 6-point rating scale (Likert Scale. In addition, we ranked the present model by reviewing the current literature for models that address vascular anastomosis skills. The trainees who participated were within their first two years of training (1.25 ± 0.46. A strong agreement in terms of the necessity of training for vascular anastomosis techniques was evident among the participating trainees (5.90 ± 0.32, who had only few prior manual experiences (total number 1.50 ± 0.53. The query revealed a strong agreement that porcine aorta is a suitable model that fits the needs for training vascular anastomosis skills (5.70 ± 0.48. Only a few bench models designed to teach surgical residents vascular anastomosis techniques were available in the literature. Conclusions The preparatory and financial resources needed to perform anastomosis skills training using porcine aorta are few. The presented bench model appears to be appropriate for

  11. Characterisation of oxidised aluminium powder: Validation of a new anodic oxidation bench

    Energy Technology Data Exchange (ETDEWEB)

    Gascoin, Nicolas, E-mail: Nicolas.Gascoin@univ-orleans.fr [PRISME Institute, Orleans University, 63 avenue de Lattre de Tassigny, 18020 Bourges (France); Gillard, Philippe; Baudry, Guillaume [PRISME Institute, Orleans University, 63 avenue de Lattre de Tassigny, 18020 Bourges (France)

    2009-11-15

    Aluminium powder is of major interest in many applications but it presents a risk due to its high explosibility, particularly when dispersed in air. The safety is directly linked to the particles oxidation because the Minimum Ignition Energy (MIE), which is required to initiate an Al dust explosion, increases with the oxide layer thickness. This study provides a controlled method to furnish reproducible homogeneous set of powder for such safety studies. Thanks to a new experimental bench, the influence on the oxidation rate of seven treatment parameters is investigated (current density, time of treatment, acid concentration, mass of powder, particles size, stirring, neutralisation by ammonia solution). The oxide content is plotted versus the current density, the time and the acid concentration to provide reference curves for further elaboration of oxidised powder. The particles size of sieved powder is measured before and after treatment by different methods (optical and Scanning Electron Microscopes, laser measurement). A high refinement of the powder in terms of size distribution is achieved thanks to the employed sieving. The present bench and the elaborated procedure are of great interest to provide well-calibrated oxidised powder directly available for safety studies. The time must be adjusted, depending on the wanted oxide content - from 2 to 18 wt.% - and the other treatment parameters must be kept constant: acid concentration (5 wt.%), current density (1 A dm{sup -2}), treated powder (20 g). In these conditions, the ratio of the oxide layer thickness on the particles diameter is found to be constant for a given oxide content whatever the particles size.

  12. Characterisation of oxidised aluminium powder: Validation of a new anodic oxidation bench

    International Nuclear Information System (INIS)

    Gascoin, Nicolas; Gillard, Philippe; Baudry, Guillaume

    2009-01-01

    Aluminium powder is of major interest in many applications but it presents a risk due to its high explosibility, particularly when dispersed in air. The safety is directly linked to the particles oxidation because the Minimum Ignition Energy (MIE), which is required to initiate an Al dust explosion, increases with the oxide layer thickness. This study provides a controlled method to furnish reproducible homogeneous set of powder for such safety studies. Thanks to a new experimental bench, the influence on the oxidation rate of seven treatment parameters is investigated (current density, time of treatment, acid concentration, mass of powder, particles size, stirring, neutralisation by ammonia solution). The oxide content is plotted versus the current density, the time and the acid concentration to provide reference curves for further elaboration of oxidised powder. The particles size of sieved powder is measured before and after treatment by different methods (optical and Scanning Electron Microscopes, laser measurement). A high refinement of the powder in terms of size distribution is achieved thanks to the employed sieving. The present bench and the elaborated procedure are of great interest to provide well-calibrated oxidised powder directly available for safety studies. The time must be adjusted, depending on the wanted oxide content - from 2 to 18 wt.% - and the other treatment parameters must be kept constant: acid concentration (5 wt.%), current density (1 A dm -2 ), treated powder (20 g). In these conditions, the ratio of the oxide layer thickness on the particles diameter is found to be constant for a given oxide content whatever the particles size.

  13. Evaluation of induced seismicity forecast models in the Induced Seismicity Test Bench

    Science.gov (United States)

    Király, Eszter; Gischig, Valentin; Zechar, Jeremy; Doetsch, Joseph; Karvounis, Dimitrios; Wiemer, Stefan

    2016-04-01

    Induced earthquakes often accompany fluid injection, and the seismic hazard they pose threatens various underground engineering projects. Models to monitor and control induced seismic hazard with traffic light systems should be probabilistic, forward-looking, and updated as new data arrive. Here, we propose an Induced Seismicity Test Bench to test and rank such models. We apply the test bench to data from the Basel 2006 and Soultz-sous-Forêts 2004 geothermal stimulation projects, and we assess forecasts from two models that incorporate a different mix of physical understanding and stochastic representation of the induced sequences: Shapiro in Space (SiS) and Hydraulics and Seismics (HySei). SiS is based on three pillars: the seismicity rate is computed with help of the seismogenic index and a simple exponential decay of the seismicity; the magnitude distribution follows the Gutenberg-Richter relation; and seismicity is distributed in space based on smoothing seismicity during the learning period with 3D Gaussian kernels. The HySei model describes seismicity triggered by pressure diffusion with irreversible permeability enhancement. Our results show that neither model is fully superior to the other. HySei forecasts the seismicity rate well, but is only mediocre at forecasting the spatial distribution. On the other hand, SiS forecasts the spatial distribution well but not the seismicity rate. The shut-in phase is a difficult moment for both models in both reservoirs: the models tend to underpredict the seismicity rate around, and shortly after, shut-in. Ensemble models that combine HySei's rate forecast with SiS's spatial forecast outperform each individual model.

  14. Procedure and layout for the development of a fatigue test on an agricultural implement by a four poster test bench

    Directory of Open Access Journals (Sweden)

    M. Cutini

    2013-09-01

    Full Text Available The increasing demand in agricultural vehicles’ power requirements, payloads and driving speeds increases issues related to tractors and farm implements exposure to solicitations. One of the main factors to be taken into account for fatigue test developing on agricultural machines is the heterogeneity of the environment and activity in which the tractor operates. In particular, for contractors the use in transport conditions both on terrain and road becomes important. As far as transport is concerned. factors mainly affecting solicitations on carried implement are soil profile roughness, tractor settings and forward speed. In this paper, CRA-ING laboratory of Treviglio, Italy, together with Frandent Group s.r.l. (Osasco, Italy, analyse the possibility of creating a solicitation profile by means of one four poster test bench for fatigue test on a carried implement simulating transport conditions. Accelerations at the hubs of the tractor were acquired during transport on terrain and reproduced with one electro-hydraulic four posters test bench on one dummy of a tractor developed for carrying the implement. Artificial bumps were mathematically created and introduced in the time history to simulate squares solicitations. Twelve hours of test were carried out. This experience confirmed the possibility of carrying out laboratory fatigue test on agricultural implements by reproducing specific field conditions solicitations with four poster test bench.

  15. Effects of low-intensity bench press training with restricted arm muscle blood flow on chest muscle hypertrophy: a pilot study.

    Science.gov (United States)

    Yasuda, Tomohiro; Fujita, Satoshi; Ogasawara, Riki; Sato, Yoshiaki; Abe, Takashi

    2010-09-01

    Single-joint resistance training with blood flow restriction (BFR) results in significant increases in arm or leg muscle size and single-joint strength. However, the effect of multijoint BFR training on both blood flow restricted limb and non-restricted trunk muscles remain poorly understood. To examine the impact of BFR bench press training on hypertrophic response to non-restricted (chest) and restricted (upper-arm) muscles and multi-joint strength, 10 young men were randomly divided into either BFR training (BFR-T) or non-BFR training (CON-T) groups. They performed 30% of one repetition maximal (1-RM) bench press exercise (four sets, total 75 reps) twice daily, 6 days week(-1) for 2 weeks. During the exercise session, subjects in the BFR-T group placed elastic cuffs proximally on both arms, with incremental increases in external compression starting at 100 mmHg and ending at 160 mmHg. Before and after the training, triceps brachii and pectoralis major muscle thickness (MTH), bench press 1-RM and serum anabolic hormones were measured. Two weeks of training led to a significant increase (Pbench press strength in BFR-T (6%) but not in CON-T (-2%). Triceps and pectoralis major MTH increased 8% and 16% (Pbench press training leads to significant increases in muscle size for upper arm and chest muscles and 1-RM strength.

  16. Water quality of hydrologic bench marks; an indicator of water quality in the natural environment

    Science.gov (United States)

    Biesecker, James E.; Leifeste, Donald K.

    1974-01-01

    Water-quality data, collected at 57 hydrologic bench-mark stations in 37 States, allow the definition of water quality in the 'natural' environment and the comparison of 'natural' water quality with water quality of major streams draining similar water-resources regions. Results indicate that water quality in the 'natural' environment is generally very good. Streams draining hydrologic bench-mark basins generally contain low concentrations of dissolved constituents. Water collected at the hydrologic bench-mark stations was analyzed for the following minor metals: arsenic, barium, cadmium, hexavalent chromium, cobalt, copper, lead, mercury, selenium, silver, and zinc. Of 642 analyses, about 65 percent of the observed concentrations were zero. Only three samples contained metals in excess of U.S. Public Health Service recommended drinking-water standards--two selenium concentrations and one cadmium concentration. A total of 213 samples were analyzed for 11 pesticidal compounds. Widespread but very low-level occurrence of pesticide residues in the 'natural' environment was found--about 30 percent of all samples contained low-level concentrations of pesticidal compounds. The DDT family of pesticides occurred most commonly, accounting for 75 percent of the detected occurrences. The highest observed concentration of DDT was 0.06 microgram per litre, well below the recommended maximum permissible in drinking water. Nitrate concentrations in the 'natural' environment generally varied from 0.2 to 0.5 milligram per litre. The average concentration of nitrate in many major streams is as much as 10 times greater. The relationship between dissolved-solids concentration and discharge per unit area in the 'natural' environment for the various physical divisions in the United States has been shown to be an applicable tool for approximating 'natural' water quality. The relationship between dissolved-solids concentration and discharge per unit area is applicable in all the physical

  17. Bench Scale Process for Low Cost CO2 Capture Using a Phase-Changing Absorbent: Final Scientific/Technical Report

    Energy Technology Data Exchange (ETDEWEB)

    Westendorf, Tiffany [GE Global Research, Niskayuna, New York (United States); Buddle, Stanlee [GE Global Research, Niskayuna, New York (United States); Caraher, Joel [GE Global Research, Niskayuna, New York (United States); Chen, Wei [GE Global Research, Niskayuna, New York (United States); Doherty, Mark [GE Global Research, Niskayuna, New York (United States); Farnum, Rachel [GE Global Research, Niskayuna, New York (United States); Giammattei, Mark [GE Global Research, Niskayuna, New York (United States); Hancu, Dan [GE Global Research, Niskayuna, New York (United States); Miebach, Barbara [GE Global Research, Niskayuna, New York (United States); Perry, Robert [GE Global Research, Niskayuna, New York (United States); Rubinsztajn, Gosia; Spiry, Irina; Wilson, Paul; Wood, Benjamin

    2017-05-31

    The objective of this project is to design and build a bench-scale process for a novel phase-changing aminosilicone-based CO2-capture solvent. The project will establish scalability and technical and economic feasibility of using a phase-changing CO2-capture absorbent for post-combustion capture of CO2 from coal-fired power plants. The U.S. Department of Energy’s goal for Transformational Carbon Capture Technologies is the development of technologies available for demonstration by 2025 that can capture 90% of emitted CO2 with at least 95% CO2 purity for less than $40/tonne of CO2 captured. In the first budget period of the project, the bench-scale phase-changing CO2 capture process was designed using data and operating experience generated under a previous project (ARPA-e project DE-AR0000084). Sizing and specification of all major unit operations was completed, including detailed process and instrumentation diagrams. The system was designed to operate over a wide range of operating conditions to allow for exploration of the effect of process variables on CO2 capture performance. In the second budget period of the project, individual bench-scale unit operations were tested to determine the performance of each of each unit. Solids production was demonstrated in dry simulated flue gas across a wide range of absorber operating conditions, with single stage CO2 conversion rates up to 75mol%. Desorber operation was demonstrated in batch mode, resulting in desorption performance consistent with the equilibrium isotherms for GAP-0/CO2 reaction. Important risks associated with gas humidity impact on solids consistency and desorber temperature impact on thermal degradation were explored, and adjustments to the bench-scale process were made to address those effects. Corrosion experiments were conducted to support selection of suitable materials of construction for the major

  18. Portable test bench for the studies concerning ion sources and ion beam extraction and focusing systems

    International Nuclear Information System (INIS)

    Cordero Lopez, F.

    1961-01-01

    A portable test bench is described, which was designed to check ion sources, ion beam extraction and focusing systems before its use in a 600 KeV Cockcroft-Walton accelerator. The vacuum possibilities of the system are specially analyzed in connection with its particular use. The whole can be considered as a portable accelerator of low energy (50 keV). (Author)

  19. Construction and Bench Testing of a Rotatable Collimator for the LHC Collimation Upgrade

    International Nuclear Information System (INIS)

    Smith, Jeffrey

    2010-01-01

    The Phase II upgrade to the LHC collimation system calls for complementing the 30 high robust Phase I graphite secondary collimators with 30 high Z Phase II collimators. The Phase II collimators must be robust in various operating conditions and accident scenarios. This paper reports on the final construction and testing of the prototype collimator to be installed in the SPS (Super Proton Synchrotron) at CERN. Bench-top measurements will demonstrate that the device is fully operational and has the mechanical and vacuum characteristics acceptable for installation in the SPS.

  20. Ultrafine particle emission characteristics of diesel engine by on-board and test bench measurement.

    Science.gov (United States)

    Huang, Cheng; Lou, Diming; Hu, Zhiyuan; Tan, Piqiang; Yao, Di; Hu, Wei; Li, Peng; Ren, Jin; Chen, Changhong

    2012-01-01

    This study investigated the emission characteristics of ultrafine particles based on test bench and on-board measurements. The bench test results showed the ultrafine particle number concentration of the diesel engine to be in the range of (0.56-8.35) x 10(8) cm(-3). The on-board measurement results illustrated that the ultrafine particles were strongly correlated with changes in real-world driving cycles. The particle number concentration was down to 2.0 x 10(6) cm(-3) and 2.7 x 10(7) cm(-3) under decelerating and idling operations and as high as 5.0 x 10(8) cm(-3) under accelerating operation. It was also indicated that the particle number measured by the two methods increased with the growth of engine load at each engine speed in both cases. The particle number presented a "U" shaped distribution with changing speed at high engine load conditions, which implies that the particle number will reach its lowest level at medium engine speeds. The particle sizes of both measurements showed single mode distributions. The peak of particle size was located at about 50-80 nm in the accumulation mode particle range. Nucleation mode particles will significantly increase at low engine load operations like idling and decelerating caused by the high concentration of unburned organic compounds.

  1. Development of Real-Time Dual-Display Handheld and Bench-Top Hybrid-Mode SD-OCTs

    Directory of Open Access Journals (Sweden)

    Nam Hyun Cho

    2014-01-01

    Full Text Available Development of a dual-display handheld optical coherence tomography (OCT system for retina and optic-nerve-head diagnosis beyond the volunteer motion constraints is reported. The developed system is portable and easily movable, containing the compact portable OCT system that includes the handheld probe and computer. Eye posterior chambers were diagnosed using the handheld probe, and the probe could be fixed to the bench-top cradle depending on the volunteers’ physical condition. The images obtained using this handheld probe were displayed in real time on the computer monitor and on a small secondary built-in monitor; the displayed images were saved using the handheld probe’s built-in button. Large-scale signal-processing procedures such as k-domain linearization, fast Fourier transform (FFT, and log-scaling signal processing can be rapidly applied using graphics-processing-unit (GPU accelerated processing rather than central-processing-unit (CPU processing. The Labview-based system resolution is 1,024 × 512 pixels, and the frame rate is 56 frames/s, useful for real-time display. The 3D images of the posterior chambers including the retina, optic-nerve head, blood vessels, and optic nerve were composed using real-time displayed images with 500 × 500 × 500 pixel resolution. A handheld and bench-top hybrid mode with a dual-display handheld OCT was developed to overcome the drawbacks of the conventional method.

  2. Studies of cooling tower components on the Mistral test bench

    International Nuclear Information System (INIS)

    Legrand, G.

    1992-07-01

    The conception of a humid air cooling tower with natural or forced draught, requires the knowledge of the thermal and aerodynamic exchange surfaces performances. Several points, among which the distribution nozzles and drift eliminators efficiencies, or the mechanical behavior of the components, should be considered. In order to be able to test this type of equipment and analyse its behavior, ELECTRICITE DE FRANCE set up in 1987 of a large dimensions test bench: MISTRAL. The investigations performed over the 3000 working hours of MISTRAL concern mainly the optimization of the counterflow and crossflow exchange surfaces proposed by the industrial cooling tower equipment suppliers. The quality of the experimental results is assured by the implementation of an extensive instrumentation on the air and water circuits, and by a severe control of the tests conditions

  3. Reliable Operation for 14500 h of a Wavelength-Stabilized Diode Laser System on a Microoptical Bench at 671 nm

    DEFF Research Database (Denmark)

    Sumpf, Bernd; Maiwald, Martin; Müller, André

    2012-01-01

    Reliability tests for wavelength-stabilized compact diode laser systems emitting at 671 nm are presented. The devices were mounted on microoptical benches with the dimensions of 13 mm $\\times\\,$4 mm. Reflecting Bragg gratings were used for wavelength stabilization and emission width narrowing...

  4. Reliability of power and velocity variables collected during the traditional and ballistic bench press exercise.

    Science.gov (United States)

    García-Ramos, Amador; Haff, G Gregory; Padial, Paulino; Feriche, Belén

    2018-03-01

    This study aimed to examine the reliability of different power and velocity variables during the Smith machine bench press (BP) and bench press throw (BPT) exercises. Twenty-two healthy men conducted four testing sessions after a preliminary BP one-repetition maximum (1RM) test. In a counterbalanced order, participants performed two sessions of BP in one week and two sessions of BPT in another week. Mean propulsive power, peak power, mean propulsive velocity, and peak velocity at each tenth percentile (20-70% of 1RM) were recorded by a linear transducer. The within-participants coefficient of variation (CV) was higher for the load-power relationship compared to the load-velocity relationship in both the BP (5.3% vs. 4.1%; CV ratio = 1.29) and BPT (4.7% vs. 3.4%; CV ratio = 1.38). Mean propulsive variables showed lower reliability than peak variables in both the BP (5.4% vs. 4.0%, CV ratio = 1.35) and BPT (4.8% vs. 3.3%, CV ratio = 1.45). All variables were deemed reliable, with the peak velocity demonstrating the lowest within-participants CV. Based upon these findings, the peak velocity should be chosen for the accurate assessment of BP and BPT performance.

  5. Relationships between Mechanical Variables in the Traditional and Close-Grip Bench Press

    Directory of Open Access Journals (Sweden)

    Lockie Robert G.

    2017-12-01

    Full Text Available The study aim was to determine relationships between mechanical variables in the one-repetition maximum (1RM traditional bench press (TBP and close-grip bench press (CGBP. Twenty resistance-trained men completed a TBP and CGBP 1RM. The TBP was performed with the preferred grip; the CGBP with a grip width of 95% biacromial distance. A linear position transducer measured: lift distance and duration; work; and peak and mean power, velocity, and force. Paired samples t-tests (p < 0.05 compared the 1RM and mechanical variables for the TBP and CGBP; effect sizes (d were also calculated. Pearson’s correlations (r; p < 0.05 computed relationships between the TBP and CGBP. 1RM, lift duration, and mean force were greater in the TBP (d = 0.30-3.20. Peak power and velocity was greater for the CGBP (d = 0.50-1.29. The 1RM TBP correlated with CGBP 1RM, power, and force (r = 0.685-0.982. TBP work correlated with CGBP 1RM, lift distance, power, force, and work (r = 0.542-0.931. TBP power correlated with CGBP 1RM, power, force, velocity, and work (r = 0.484-0.704. TBP peak and mean force related to CGBP 1RM, power, and force (r = 0.596-0.980. Due to relationships between the load, work, power, and force for the TBP and CGBP, the CGBP could provide similar strength adaptations to the TBP with long-term use. The velocity profile for the CGBP was different to that of the TBP. The CGBP could be used specifically to improve high-velocity, upper-body pushing movements.

  6. Reliability Analysis of Traditional and Ballistic Bench Press Exercises at Different Loads

    Directory of Open Access Journals (Sweden)

    García-Ramos Amador

    2015-09-01

    Full Text Available The purpose of this study was to determine test–retest reliability for peak barbell velocity (Vpeak during the bench press (BP and bench press throw (BPT exercises for loads corresponding to 20–70% of one-repetition maximum (1RM. Thirty physically active collegiate men conducted four evaluations after a preliminary BP 1RM determination (1RM·bw-1 = 1.02 ± 0.16 kg·kg-1. In counterbalanced order, participants performed two sessions of the BP in one week and two sessions of the BPT in another week. Recovery time between sessions within the same week was 48 hours and recovery time between sessions of different weeks was 120 hours. On each day of evaluation the individual load-velocity relationship at each tenth percentile (20–70% of 1RM in a Smith machine for the BP or BPT was determined. Participants performed three attempts per load, but only the best repetition (highest Vpeak, registered by a linear position transducer, was analysed. The BPT resulted in a significantly lower coefficient of variation (CV for the whole load–velocity relationship, compared to the BP (2.48% vs. 3.22%; p = 0.040. Test–retest intraclass correlation coefficients (ICCs ranged from r = 0.94-0.85 for the BPT and r = 0.91-0.71 for the BP (p < 0.001. The reduction in the biological within-subject variation in BPT exercise could be promoted by the braking phase that obligatorily occurs during a BP executed with light or moderate loads. Therefore, we recommend the BPT exercise for a most accurate assessment of upper-body velocity.

  7. One repetition maximum bench press performance: a new approach for its evaluation in inexperienced males and females: a pilot study.

    Science.gov (United States)

    Bianco, Antonino; Filingeri, Davide; Paoli, Antonio; Palma, Antonio

    2015-04-01

    The aim of this study was to evaluate a new method to perform the one repetition maximum (1RM) bench press test, by combining previously validated predictive and practical procedures. Eight young male and 7 females participants, with no previous experience of resistance training, performed a first set of repetitions to fatigue (RTF) with a workload corresponding to ⅓ of their body mass (BM) for a maximum of 25 repetitions. Following a 5-min recovery period, a second set of RTF was performed with a workload corresponding to ½ of participants' BM. The number of repetitions performed in this set was then used to predict the workload to be used for the 1RM bench press test using Mayhew's equation. Oxygen consumption, heart rate and blood lactate were monitored before, during and after each 1RM attempt. A significant effect of gender was found on the maximum number of repetitions achieved during the RTF set performed with ½ of participants' BM (males: 25.0 ± 6.3; females: 11.0x± 10.6; t = 6.2; p bench press test. We conclude that, by combining previously validated predictive equations with practical procedures (i.e. using a fraction of participants' BM to determine the workload for an RTF set), the new method we tested appeared safe, accurate (particularly in females) and time-effective in the practical evaluation of 1RM performance in inexperienced individuals. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Spatial and temporal dynamics of water in the root environment of potted plants on a flooded bench fertigation system

    NARCIS (Netherlands)

    Otten, W.; Raats, P.A.C.; Baas, R.; Challa, H.; Kabat, P.

    1999-01-01

    The relationship between evapotranspiration of potted Ficus benjamina plants on a flooded bench fertigation system and the distribution of water in the root zone was studied in detail for a range of fertigation schedules. The physical characteristics of the peat-based potting medium were described

  9. Linearly chirped fiber Bragg grating response to thermal gradient: from bench tests to the real-time assessment during in vivo laser ablations of biological tissue

    Science.gov (United States)

    Saccomandi, Paola; Varalda, Ambra; Gassino, Riccardo; Tosi, Daniele; Massaroni, Carlo; Caponero, Michele A.; Pop, Raoul; Korganbayev, Sanzhar; Perrone, Guido; Diana, Michele; Vallan, Alberto; Costamagna, Guido; Marescaux, Jacques; Schena, Emiliano

    2017-09-01

    The response of a fiber optic sensor [linearly chirped fiber Bragg grating (LCFBG)] to a linear thermal gradient applied on its sensing length (i.e., 1.5 cm) has been investigated. After these bench tests, we assessed their feasibility for temperature monitoring during thermal tumor treatment. In particular, we performed experiments during ex vivo laser ablation (LA) in pig liver and in vivo thermal ablation in animal models (pigs). We investigated the following: (i) the relationship between the full width at half maximum of the LCFBG spectrum and the temperature difference among the extremities of the LCFBG and (ii) the relationship between the mean spectrum wavelength and the mean temperature acting on the LCFBG sensing area. These relationships showed a linear trend during both bench tests and LA in animal models. Thermal sensitivity was significant although different values were found with regards to bench tests and animal experiments. The linear trend and significant sensitivity allow hypothesizing a future use of this kind of sensor to monitor both temperature gradient and mean temperature within a tissue undergoing thermal treatment.

  10. Effect of dynamic random leaks on the monitoring accuracy of home mechanical ventilators: a bench study.

    Science.gov (United States)

    Sogo, Ana; Montanyà, Jaume; Monsó, Eduard; Blanch, Lluís; Pomares, Xavier; Lujàn, Manel

    2013-12-10

    So far, the accuracy of tidal volume (VT) and leak measures provided by the built-in software of commercial home ventilators has only been tested using bench linear models with fixed calibrated and continuous leaks. The objective was to assess the reliability of the estimation of tidal volume (VT) and unintentional leaks in a single tubing bench model which introduces random dynamic leaks during inspiratory or expiratory phases. The built-in software of four commercial home ventilators and a fifth ventilator-independent ad hoc designed external software tool were tested with two levels of leaks and two different models with excess leaks (inspiration or expiration). The external software analyzed separately the inspiratory and expiratory unintentional leaks. In basal condition, all ventilators but one underestimated tidal volume with values ranging between -1.5 ± 3.3% to -8.7% ± 3.27%. In the model with excess of inspiratory leaks, VT was overestimated by all four commercial software tools, with values ranging from 18.27 ± 7.05% to 35.92 ± 17.7%, whereas the ventilator independent-software gave a smaller difference (3.03 ± 2.6%). Leaks were underestimated by two applications with values of -11.47 ± 6.32 and -5.9 ± 0.52 L/min. With expiratory leaks, VT was overestimated by the software of one ventilator and the ventilator-independent software and significantly underestimated by the other three, with deviations ranging from +10.94 ± 7.1 to -48 ± 23.08%. The four commercial tools tested overestimated unintentional leaks, with values between 2.19 ± 0.85 to 3.08 ± 0.43 L/min. In a bench model, the presence of unintentional random leaks may be a source of error in the measurement of VT and leaks provided by the software of home ventilators. Analyzing leaks during inspiration and expiration separately may reduce this source of error.

  11. Shouldn't the Bench be a Mirror? The Diversity of the Canadian Judiciary

    Directory of Open Access Journals (Sweden)

    Avner Levin

    2017-12-01

    Full Text Available This paper assesses the diversity of the judicial bench in the Canadian metropolitan areas of Vancouver, and Montreal. Five years ago, a study by Ryerson’s Diversity Institute confirmed that visible minorities make up only 8.3% of the judges in the most diverse city in Canada, Toronto. The paper discusses whether a representative canadian judiciary enhances (and perhaps is even a pre-requisite for the Administration of Justice, and whether a more diverse bench, where subjective identity may play a central role, would compromise the presumed objectivity of judicial decision-making. Este artículo examina la diversidad del sector judicial de los centros urbanos más diversos de Canadá –Toronto, Vancouver y Montreal– y mide la brecha entre la composición demográfica del cuerpo judicial y la población a la cual sirve. A continuación, el artículo toma en consideración los factores que contribuyen a perpetuar la homogeneidad de los juzgados canadienses, y hace referencia a los argumentos de que un proceso de nombramiento que tomara en cuenta la identidad podría poner en entredicho la meritocracia o la presunta objetividad de la toma de decisiones judiciales. Nosotros argumentamos que unos datos públicos fiables sobre la composición de los juzgados y una visión y una estrategia claras por parte del Gobierno son cruciales para la administración de la justicia en los juzgados canadienses.DOWNLOAD THIS PAPER FROM SSRN: https://ssrn.com/abstract=3034201

  12. Great expectations - Epigenetics and the meandering path from bench to bedside

    DEFF Research Database (Denmark)

    Häfner, Sophia J; Lund, Anders H

    2016-01-01

    Making quick promises of major biomedical breakthroughs based on exciting discoveries at the bench is tempting. But the meandering path from fundamental science to life-saving clinical applications can be fraught with many hurdles. Epigenetics, the study of potentially heritable changes of gene...... function without modification of the underlying DNA sequence, has dominated the biological research field during the last decade and encountered a large public success. Driven by the unfolding of molecular biology and recent technological progress, the term has evolved significantly and shifted from....... However, while exciting reports of biological phenomena involving DNA methylation and histone modifications fill up the scientific literature, the realistic clinical applications of epigenetic medicines remain somewhat blurry. Here, we discuss the state of the art and speculate how epigenetics might...

  13. Coal flotation - bench-scale study. Flotacao de carvao estudo em escala de bancada

    Energy Technology Data Exchange (ETDEWEB)

    Campos, A.R. de; Almeida, S L.M. de; Santos, A.T. dos

    1979-01-01

    Run-of-mine coal and pre-washed coal from Santa Catarina, Brazil, were characterized using washability curves and by particle size analysis after crushing. Bench-scale froth flotation tests were then conducted with the pre-washed coal. Kerosene and diesel oil were used as the collectors, and pine oil as the frother. The influence of starch (as depressor) on flotation was also studied. The effects of feed particle size, pH, collector addition, frother addition, depressor addition and flotation time were investigated. A 9.5% ash content coal could be obtained with a mass recovery of about 29%. (17 refs.)

  14. Efficacy of the National Football League-225 Test to Track Changes in One Repetition Maximum Bench Press After Training in National Collegiate Athletic Association Division IA Football Players.

    Science.gov (United States)

    Mann, J Bryan; Ivey, Pat A; Stoner, Josh D; Mayhew, Jerry L; Brechue, William F

    2015-11-01

    Numerous investigations have attested to the efficacy of the National Football League (NFL)-225 test to estimate one repetition maximum (1RM) bench press. However, no studies have assessed the efficacy of the test to track changes in strength across a training program. The purpose of this study was to determine the accuracy of the NFL-225 test for determining the change in 1RM bench press in National Collegiate Athletic Association Division IA college football players after training. Over a 4-year period, players (n = 203) were assessed before and after a 6-week off-season resistance program for 1RM bench press and repetitions completed with 102.3 kg (225 lbs). Test sessions typically occurred within 1 week of each other. Players significantly increased 1RM by 4.2 ± 8.6 kg and NFL-225 repetitions by 0.9 ± 2.3, although the effect size (ES) for each was trivial (ES = 0.03 and 0.07, respectively). National Football League 225 prediction equations had higher correlations with 1RM before training (intraclass correlation coefficient [ICC] = 0.95) than after training (ICC = 0.75). The correlation between the change in NFL-225 repetitions and change in 1RM was low and negative (r = -0.22, p bench press strength after short-term training.

  15. Loading Intensity Prediction by Velocity and the OMNI-RES 0-10 Scale in Bench Press.

    Science.gov (United States)

    Naclerio, Fernando; Larumbe-Zabala, Eneko

    2017-02-01

    Naclerio, F and Larumbe-Zabala, E. Loading intensity prediction by velocity and the OMNI-RES 0-10 scale in bench press. J Strength Cond Res 32(1): 323-329, 2017-This study examined the possibility of using movement velocity and the perceived exertion as indicators of relative load in the bench press (BP) exercise. A total of 308 young, healthy, resistance trained athletes (242 men and 66 women) performed a progressive strength test up to the one repetition maximum for the individual determination of the full load-velocity and load-exertion relationships. Longitudinal regression models were used to predict the relative load from the average velocity (AV) and the OMNI-Resistance Exercise Scales (OMNI-RES 0-10 scale), considering sets as the time-related variable. Load associated with the AV and the OMNI-RES 0-10 scale value expressed after performing a set of 1-3 repetitions were used to construct 2 adjusted predictive equations: Relative load = 107.75 - 62.97 × average velocity; and Relative load = 29.03 + 7.26 × OMNI-RES 0-10 scale value. The 2 models were capable of estimating the relative load with an accuracy of 84 and 93%, respectively. These findings confirm the ability of the 2 calculated regression models, using load-velocity and load-exertion from the OMNI-RES 0-10 scale, to accurately predict strength performance in BP.

  16. A new laryngeal mask supraglottic airway device with integrated balloon line: a descriptive and comparative bench study

    Directory of Open Access Journals (Sweden)

    Zhou YH

    2016-11-01

    Full Text Available YingHai Zhou,1 Korinne Jew2 1Research & Development, Patient Monitoring & Recovery, Medtronic Technology Center, Shanghai, People’s Republic of China; 2Medical Affairs, Minimally Invasive Therapies Group, Medtronic, Boulder, CO, USA Abstract: Laryngeal masks are invasive devices for airway management placed in the supraglottic position. The Shiley™ laryngeal mask (Shiley™ LM features an integrated inflation tube and airway shaft to facilitate product insertion and reduce the chance of tube occlusion when patients bite down. This study compared the Shiley LM to two other disposable laryngeal mask devices, the Ambu® AuraStraight™ and the LMA Unique™. Overall device design, tensile strength, flexibility of various structures, and sealing performance were measured. The Shiley LM is structurally stronger and its shaft is more resistant to compression than the other devices. The Shiley LM is generally less flexible than the other devices, but this relationship varies with device size. Sealing performance of the devices was similar in a bench assay. The results of this bench study demonstrate that the new Shiley LM resembles other commercially available laryngeal mask devices, though it exhibits greater tensile strength and lower flexibility. Keywords: laryngeal mask, supraglottic airway, supralaryngeal device

  17. Relationship between throwing velocity, muscle power, and bar velocity during bench press in elite handball players.

    Science.gov (United States)

    Marques, Mario C; van den Tilaar, Roland; Vescovi, Jason D; Gonzalez-Badillo, Juan Jose

    2007-12-01

    The purpose of this study was to examine the relationship between ball-throwing velocity during a 3-step running throw and dynamic strength, power, and bar velocity during a concentric-only bench-press exercise in team-handball players. Fourteen elite senior male team-handball players volunteered to participate. Each volunteer had power and bar velocity measured during a concentric-only bench-press test with 26, 36, and 46 kg, as well as having 1-repetition-maximum (1-RMBP) strength determined. Ball-throwing velocity was evaluated with a standard 3-step running throw using a radar gun. Ball-throwing velocity was related to the absolute load lifted during the 1-RMBP (r = .637, P = .014), peak power using 36 kg (r = .586, P = .028) and 46 kg (r = .582, P = .029), and peak bar velocity using 26 kg (r = .563, P = .036) and 36 kg (r = .625, P = .017). The results indicate that throwing velocity of elite team-handball players is related to maximal dynamic strength, peak power, and peak bar velocity. Thus, a training regimen designed to improve ball-throwing velocity in elite male team-handball players should include exercises that are aimed at increasing both strength and power in the upper body.

  18. Study and designing of the ''caliprax'' measurement bench; Etude et realisation du banc ''caliprax''

    Energy Technology Data Exchange (ETDEWEB)

    Barriere, J.Ch

    2001-09-01

    Probing the matter in order to check its elementary constituents, that is the goal of the particle physic. In this field, the experiments consist in colliding highly energetic particle beams and observing the new born particles. These observations are based on big particle detectors whose running is dependant on the precise knowledge of their geometry (position of the detection chambers). To achieve this, the detectors are equipped with alignment sensors, which have to be calibrated before. This document describes the study and the making of a calibration bench for the 'Praxial' (PRoximity AXIAL) type sensors, and other works related to these sensors. In a first part, we determine and apply a method to set the tools used to fix the sensor stands on the detection chambers. These settings are made with the use of a tridimensional measuring machine. Then, we study the stands themselves. These investigations concern mechanics: positioning quality of the sensors in their stands, bending of the supports due to the tightening. In this part too, the studies are in the field of dimensional metrology. After this, the works are reoriented toward the bench, with the choice of the displacement sensors among two different technologies: optical, with the Rasnik system, and mechanical, with linear probes as LVDT (Linear Variable Differential Transformer). Following the discovery of an ambiguity on the Rasnik system, we go on the tests to understand its behaviour. We introduce the theory of the alignment sensors calibration, which is based on a minimization calculation. The computer programs are explained in a chapter, and in an other, the implementation of the quality assurance procedures. An other part describes the mechanical studies and the problems they cause. Because of a delay onset of the project, we make a model of the bench. This dummy allows us to test every single function of the final bench. With this device, we record manually the first calibration data and

  19. Partial resonance minimization effects on transformers benches; Minimizacao dos efeitos da ressonancia parcial de banco de transformadores

    Energy Technology Data Exchange (ETDEWEB)

    Contente, A D; Rodrigues, C G; Kataoka, D; Silveira, E; Oliveira, Junior, G F.B. de; Gonzaga, J L [Companhia Energetica de Sao Paulo, SP (Brazil)

    1992-12-31

    The problem caused by partial resonance effect in the phase regulation winding in Taubate substation transformer bench is discussed. Studies and decisions taken to use capacitors on tertiary winding of the transformers set, are presented. Damages caused by resonance on transformer contacts, studies and assays made to solve the problem, resonance frequency measured, and capacitors values calculation, are also shown 3 refs., 3 figs., 2 tabs.

  20. Pattern Generator for Bench Test of Digital Boards

    Science.gov (United States)

    Berkun, Andrew C.; Chu, Anhua J.

    2012-01-01

    All efforts to develop electronic equipment reach a stage where they need a board test station for each board. The SMAP digital system consists of three board types that interact with each other using interfaces with critical timing. Each board needs to be tested individually before combining into the integrated digital electronics system. Each board needs critical timing signals from the others to be able to operate. A bench test system was developed to support test of each board. The test system produces all the outputs of the control and timing unit, and is delivered much earlier than the timing unit. Timing signals are treated as data. A large file is generated containing the state of every timing signal at any instant. This file is streamed out to an IO card, which is wired directly to the device-under-test (DUT) input pins. This provides a flexible test environment that can be adapted to any of the boards required to test in a standalone configuration. The problem of generating the critical timing signals is then transferred from a hardware problem to a software problem where it is more easily dealt with.

  1. Design of a test-bench to validate a model of a thermal window design; Diseno de un banco de ensayos para la validacion de un modelo de diseno termico de ventanas

    Energy Technology Data Exchange (ETDEWEB)

    Saavedra O, Claudio; Fissore Sch, Adelqui; Mottard, Jean-Michel [Universidad de Concepcion (Chile). Facultad de Ingenieria. Dept. de Ingenieria Mecanica]. E-mail: clsaaved @udec.cl; afissore@udec.cl

    2000-07-01

    Paper presents the design of a test-bench and instrumentation to validate a window thermal mathematical model. The test-bench simulate the thermal performance of a office with a only one wall in directly contact with outdoors, where a single glass window is mounted. To obtain a similar heat transfer relation as the real building, the chamber has been designed and manufactured with an inner and an outer envelope, and with an air spacing maintaining at the same temperature that the test chamber. To change the window size, the test-bench is equipped with a single modifiable outer wall. Instrumentation and methods of measurement for solar radiation, infra red outdoor radiation, indoor and outdoor air temperatures, wind velocity, heat transfer, air ventilating flow and temperature, wall temperatures, etc. are specified. (author)

  2. Loading intensity prediction by velocity and the OMNI-RES 0–10 scale in bench press

    OpenAIRE

    Naclerio, Fernando; Larumbe-Zabala, Eneko

    2017-01-01

    This study examined the possibility of using movement velocity and the perceived exertion as indicators of relative load in the bench press exercise. Three hundred eight young, healthy, resistance trained athletes (242 male and 66 female) performed a progressive strength test up to the one-repetition maximum for the individual determination of the full load-velocity and load-exertion relationships. Longitudinal regression models were used to predict the relative load from the average velocity...

  3. Virtual Reality Compared with Bench-Top Simulation in the Acquisition of Arthroscopic Skill: A Randomized Controlled Trial.

    Science.gov (United States)

    Banaszek, Daniel; You, Daniel; Chang, Justues; Pickell, Michael; Hesse, Daniel; Hopman, Wilma M; Borschneck, Daniel; Bardana, Davide

    2017-04-05

    Work-hour restrictions as set forth by the Accreditation Council for Graduate Medical Education (ACGME) and other governing bodies have forced training programs to seek out new learning tools to accelerate acquisition of both medical skills and knowledge. As a result, competency-based training has become an important part of residency training. The purpose of this study was to directly compare arthroscopic skill acquisition in both high-fidelity and low-fidelity simulator models and to assess skill transfer from either modality to a cadaveric specimen, simulating intraoperative conditions. Forty surgical novices (pre-clerkship-level medical students) voluntarily participated in this trial. Baseline demographic data, as well as data on arthroscopic knowledge and skill, were collected prior to training. Subjects were randomized to 5-week independent training sessions on a high-fidelity virtual reality arthroscopic simulator or on a bench-top arthroscopic setup, or to an untrained control group. Post-training, subjects were asked to perform a diagnostic arthroscopy on both simulators and in a simulated intraoperative environment on a cadaveric knee. A more difficult surprise task was also incorporated to evaluate skill transfer. Subjects were evaluated using the Global Rating Scale (GRS), the 14-point arthroscopic checklist, and a timer to determine procedural efficiency (time per task). Secondary outcomes focused on objective measures of virtual reality simulator motion analysis. Trainees on both simulators demonstrated a significant improvement (p virtual reality simulation group consistently outperformed the bench-top model group in the diagnostic arthroscopy crossover tests and in the simulated cadaveric setup. Furthermore, the virtual reality group demonstrated superior skill transfer in the surprise skill transfer task. Both high-fidelity and low-fidelity simulation trainings were effective in arthroscopic skill acquisition. High-fidelity virtual reality

  4. Bench-scale testing of a micronized magnetite, fine-coal cleaning process

    Energy Technology Data Exchange (ETDEWEB)

    Suardini, P.J. [Custom Coals, International, Pittsburgh, PA (United States)

    1995-11-01

    Custom Coals, International has installed and is presently testing a 500 lb/hr. micronized-magnetite, fine-coal cleaning circuit at PETC`s Process Research Facility (PRF). The cost-shared project was awarded as part of the Coal Preparation Program`s, High Efficiency Preparation Subprogram. The project includes design, construction, testing, and decommissioning of a fully-integrated, bench-scale circuit, complete with feed coal classification to remove the minus 30 micron slimes, dense medium cycloning of the 300 by 30 micron feed coal using a nominal minus 10 micron size magnetite medium, and medium recovery using drain and rinse screens and various stages and types of magnetic separators. This paper describes the project circuit and goals, including a description of the current project status and the sources of coal and magnetite which are being tested.

  5. Facility ''Bench of Stationary Engines for Study of Emissions (E65-PO) CIEMAT''

    International Nuclear Information System (INIS)

    Rojas Garcia, E.; Rodriguez Maroto, J.J.

    2007-01-01

    The Project of Technology of Aerosols in Generation of Energy, of the Department of Fossil Fuels of the CIEMAT, began in the year 2004, a research activity line, based on the study of the emissions coming from internal combustion engines, particularly of Diesel technology. Activity was continued by the Polluting Emissions Group of the Department of Environment, when becoming the original Project in this Group. From the concession to the Group, of the project GR/AMB/0119/2004 Evaluation of the Emissions of Biodiesel supported by the Autonomous Community of Madrid together with the European Regional Development Fund (ERDF), this activity was encourage, with the design, assembly and to get ready of the facility Bench of stationary engines for study of emissions, located in the building 65 at CIEMAT, Madrid. The present report constitutes a detailed technical description of each one of the elements that the installation Bench of stationary engines for study of emissions it integrated within the framework of the referred project (GR/AMB/0119/2004) and whose capacity includes studies of the effects of the engine, fuel, operation conditions, and methodology of sampling and measurement of emissions (gases and particles). The fundamental parts of facility describes in the present report are: engine test cell (cabin of sound insulation , ventilation and refrigeration system, anti vibrations mounting, engine, dynamometric brake), lines of preconditioning of particles and gases emissions (exhaust line, primary and secondary dilution lines, gases cleaning system...), other general parts of facility (sampling and measurement station, service lines...). The present report not only reflects the characteristics of the systems involved, but rather also in certain cases specified the procedure and reason for their choice. (Author) 10 refs

  6. Thermical Load Calculation and Capacity of Cooling and Venting Equipment of a Diesel Engine Emissions Study Bench; Calculo de Cargas Termicas y Capacidad de los Equipos de Refrigeracion y Ventilacion de un Banco de Estudio de Emisiones de Motores Diesel

    Energy Technology Data Exchange (ETDEWEB)

    Rojas Garcia, E.; Fonseca Gonzalez, N. A.

    2005-07-01

    The present report tries to develop the calculation of thermical loads and to define the capacity of the equipments of cooling and ventilation that should have the engines test bench that is being ensemble in the installation of the CIEMAT named {sup D}iesel engine emissions study bench (E65-P0). The test bench is formed essentially by a dynamometrical brake and an engine connected at previous one, both of them inside a cabin of isolation acoustic. The thermical loads to be dissipated will be calculated for all the elements that compose the bench and considering his maximum values, to determine the suitable system of cooling air - water of the devices and ventilation in the cabin. (Author) 2 refs.

  7. Development of The Structural and Functional Design of the Laboratory Bench for Experimental Research Diesel Generator Sets on Variable Speed

    Directory of Open Access Journals (Sweden)

    Obuhov Sergei

    2017-01-01

    Full Text Available A diesel generator set working at variable speed to save fuel is studied. A description is provided of a laboratory bench for conducting experimental studies of a variable speed diesel generator set. Its component parts are described, and its technical characteristics are given.

  8. Use of a Combination of Vertical and Horizontal Boreholes in Massive Blasting of Benches in the Surface Quarry Rodež

    Science.gov (United States)

    Tori, Matija; Vajović, Stanojle; Goleš, Niko; Muhić, Elvir; Peternel, Miha

    2017-12-01

    This article deals with the extraction of minerals (limestone/marl/flysch) in the quarry Rodež, which is located in western Slovenia. During the extraction of minerals in a quarry, drilling and blasting of benches are used. The focus of the article is on the analysis of the parameters related to drilling and blasting in surface excavations when using a combination of explosions and introducing horizontal wells along with vertical holes in the bench. On the basis of the analysis of basic parameters through a combination of drilling horizontal wells and charging those with the ammonal + Anfex explosive, analyses of effects of seismic disturbances on potentially affected buildings have also been conducted. The article is connected to and deals exclusively with the basic parameters of drilling and blasting, with the introduction of horizontal drilling and with the analysis of seismic measurements of threatened buildings in accordance with the German standard German Institute for Standardisation (DIN) 4150 during the use of a new method of blasting.

  9. Method, apparatus and system for managing queue operations of a test bench environment

    Science.gov (United States)

    Ostler, Farrell Lynn

    2016-07-19

    Techniques and mechanisms for performing dequeue operations for agents of a test bench environment. In an embodiment, a first group of agents are each allocated a respective ripe reservation and a second set of agents are each allocated a respective unripe reservation. Over time, queue management logic allocates respective reservations to agents and variously changes one or more such reservations from unripe to ripe. In another embodiment, an order of servicing agents allocated unripe reservations is based on relative priorities of the unripe reservations with respect to one another. An order of servicing agents allocated ripe reservations is on a first come, first served basis.

  10. Performance of flash ADCs in the 100 MHz range: I. Test bench and preliminary results

    International Nuclear Information System (INIS)

    Crawley, H.B.; McKay, R.; Meyer, W.T.; Rosenberg, E.I.; Thomas, W.D.

    1990-01-01

    We describe a systematic study of the performance of commercially available Flash ADCs in the 100 Megasample per second range, which might be suitable for use in the Superconducting Super Collider. Performance characteristics are measured using a CAMAC based test bench which is described. Among the FADC performance characteristics reported are linearity, differential linearity and the effective number of bits. This paper is the first in a series of reports to be presented within the next year as our tests continue. 6 refs., 2 figs., 1 tab

  11. A bench-scale biotreatability methodology to evaluate field bioremediation

    International Nuclear Information System (INIS)

    Saberiyan, A.G.; MacPherson, J.R. Jr.; Moore, R.; Pruess, A.J.; Andrilenas, J.S.

    1995-01-01

    A bench-scale biotreatability methodology was designed to assess field bioremediation of petroleum contaminated soil samples. This methodology was performed successfully on soil samples from more than 40 sites. The methodology is composed of two phases, characterization and experimentation. The first phase is physical, chemical, and biological characterization of the contaminated soil sample. This phase determines soil parameters, contaminant type, presence of indigenous contaminant-degrading bacteria, and bacterial population size. The second phase, experimentation, consists of a respirometry test to measure the growth of microbes indirectly (via generation of CO 2 ) and the consumption of their food source directly (via contaminant loss). Based on a Monod kinetic analysis, the half-life of a contaminant can be calculated. Abiotic losses are accounted for based on a control test. The contaminant molecular structure is used to generate a stoichiometric equation. The stoichiometric equation yields a theoretical ratio for mg of contaminant degraded per mg of CO 2 produced. Data collected from the respirometry test are compared to theoretical values to evaluate bioremediation feasibility

  12. Application of magnetic resonance imaging (MRI) to determine the influence of fluid dynamics on desulfurization in Bench scale reactors

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, N.L.; Reimert, R. [Engler-Bunte-Institut, Bereich Gas, Erdoel und Kohle, Universitaet Karlsruhe (T.H.) (Germany); Hardy, E.H. [Institut fuer Mechanische Verfahrenstechnik und Mechanik, Universitaet Karlsruhe (T.H.) (Germany)

    2006-07-15

    The influence of fluid dynamics on the hydrodesulfurization (HDS) reactions of a diesel oil in bench-scale reactors was evaluated. The porosities and liquid saturations of catalyst beds were quantified by using the MRI technique. The gas-liquid systems used in the experiments were nitrogen diesel and hydrogen diesel. An apparatus was especially constructed, allowing in situ measurements of gas and liquid distributions in packed beds at elevated pressure and temperature up to 20 bar and 200 C, respectively. The reactor itself had a length of 500 mm and an internal diameter of 19 mm. The packed beds used in this MRI study consisted of: (1) 2 mm diameter nonporous spherical glass beads and (2) 1.3 mm diameter porous Al{sub 2}O{sub 3} trilobes having the same size as the original trilobe catalyst used in HDS bench-scale experiments. The superficial gas and liquid velocities were set within the range of trickle flow, e.g., u{sub 0G} = 20-500 mm/s and u{sub 0L} = 0.1-6 mm/s. In parallel with the MRI experiments, the hydrodesulfurization of a gas oil was investigated in a bench-scale plant. Its reactor had the same dimensions of the trickle-bed column used in the MRI experiments and was filled with original trilobe catalyst. These catalytic experiments were carried out at a wide range of operating conditions (p = 30-80 bar, T = 300-380 C, LHSV = 1-4 h{sup -1}). The results of both fluid dynamic and catalytic reaction experiments were then combined for developing a simulation model to predict the HDS performance by accounting for fluid dynamic nonidealities. (Abstract Copyright [2006], Wiley Periodicals, Inc.)

  13. The Hundred-Year Emotion War: Are Emotions Natural Kinds or Psychological Constructions? Comment on Lench, Flores, and Bench (2011)

    Science.gov (United States)

    Lindquist, Kristen A.; Siegel, Erika H.; Quigley, Karen S.; Barrett, Lisa Feldman

    2013-01-01

    For the last century, there has been a continuing debate about the nature of emotion. In the most recent offering in this scientific dialogue, Lench, Flores, and Bench (2011) reported a meta-analysis of emotion induction research and claimed support for the natural kind hypothesis that discrete emotions (e.g., happiness, sadness, anger, and…

  14. Robotic splenectomy with ex vivo bench surgery and hemi-spleen autotransplant: the first report.

    Science.gov (United States)

    Giulianotti, Pier Cristoforo; Daskalaki, Despoina; Gonzalez-Ciccarelli, Luis F; Bianco, Francesco M

    2017-06-01

    We describe our experience with what is, to our knowledge, the first case of robotic assisted ex vivo partial splenectomy with auto-transplantation for a benign non parasitic cyst. The patient is a 32 year-old female with a giant, benign splenic cyst causing persistent abdominal pain. Preoperative imaging showed a cystic lesion measuring 8.3 × 7.6 cm, in the middle portion of the spleen. Due to the central location of the bulky lesion a partial splenectomy was not feasible. As an alternative to a total splenectomy, a possible reimplantation of hemi-spleen after bench surgery was offered. We proceeded with a robotic total splenectomy and bench hemisplenectomy, preserving the lower pole and a portion of the middle segment of the organ. A robotic reconstruction of the splenic vessels was then performed intra-abdominally. The reperfusion was optimal. The total operative time was 305 min, with 78 min of robotic time. Postoperative ultrasound confirmed a patent arterial and venous flow. The postoperative course was uneventful and the patient was discharged on postoperative day 4. The pathology report was consistent with epithelial cyst of the spleen. The patient is doing well at 6-month follow-up. The optimized vision and dexterity provided by the robotic system allowed a safe and precise reconstruction of the splenic vessels, even in a deep and narrow operative field. Partial splenectomy with autotransplantation of the organ was thus achieved, avoiding a total splenectomy in a young patient.

  15. Status of the bench-test system for the tubes in the HIMAC DTL linac

    International Nuclear Information System (INIS)

    Fujimoto, T.; Ishikawa, S.; Kobayashi, C.

    2000-01-01

    The tetrode tube of SIEMENS RS2074SK is used for HIMAC DTL (Drift Tube Linac) 1.4 MW final amplifiers. We installed a bench-test system for this tube in 1999. This system can be used under low power operation with CW mainly for filament aging. This system consists of DC sources, drive-amplifier (5 kW transistor amplifier) and 3/4λ coaxial input and output circuits. We will also use this system to improve the DTL final amplifiers, for example to reduce the parasitic oscillation level. This paper describes status of this system. (author)

  16. Determination of uranium in bench test by L_Ⅲ-absorption edge method

    International Nuclear Information System (INIS)

    Song You; Zheng Weiming; Liu Guijiao; Chen Chen

    2014-01-01

    By independent research L_Ⅲ--absorption edge densimeter, an analytical method for uranium sample with the concentration from 20 g/L to 200 g/L was developed. The fitting area for uranium measurement was determined through experiment. The left fitting area was 1659-1856 channel, and the right one was 2063-2280 channel. The uranium L_Ⅲ--absorption edge was at 1995 channel. The results show that the influence of HNO_3 concentration lower than 9 mol/L, Al and Fe concentration lower than 10 g/L was negligibly small. The uranium measurement precision is better than 0.5%, and the instrument stability is good. Some samples in bench test of uranium recovery were determined. The results are satisfactory. (authors)

  17. Real-time cavity simulator-based low-level radio-frequency test bench and applications for accelerators

    Science.gov (United States)

    Qiu, Feng; Michizono, Shinichiro; Miura, Takako; Matsumoto, Toshihiro; Liu, Na; Wibowo, Sigit Basuki

    2018-03-01

    A Low-level radio-frequency (LLRF) control systems is required to regulate the rf field in the rf cavity used for beam acceleration. As the LLRF system is usually complex, testing of the basic functions or control algorithms of this system in real time and in advance of beam commissioning is strongly recommended. However, the equipment necessary to test the LLRF system, such as superconducting cavities and high-power rf sources, is very expensive; therefore, we have developed a field-programmable gate array (FPGA)-based cavity simulator as a substitute for real rf cavities. Digital models of the cavity and other rf systems are implemented in the FPGA. The main components include cavity baseband models for the fundamental and parasitic modes, a mechanical model of the Lorentz force detuning, and a model of the beam current. Furthermore, in our simulator, the disturbance model used to simulate the power-supply ripples and microphonics is also carefully considered. Based on the presented cavity simulator, we have established an LLRF system test bench that can be applied to different cavity operational conditions. The simulator performance has been verified by comparison with real cavities in KEK accelerators. In this paper, the development and implementation of this cavity simulator is presented first, and the LLRF test bench based on the presented simulator is constructed. The results are then compared with those for KEK accelerators. Finally, several LLRF applications of the cavity simulator are illustrated.

  18. Real-time cavity simulator-based low-level radio-frequency test bench and applications for accelerators

    Directory of Open Access Journals (Sweden)

    Feng Qiu

    2018-03-01

    Full Text Available A Low-level radio-frequency (LLRF control systems is required to regulate the rf field in the rf cavity used for beam acceleration. As the LLRF system is usually complex, testing of the basic functions or control algorithms of this system in real time and in advance of beam commissioning is strongly recommended. However, the equipment necessary to test the LLRF system, such as superconducting cavities and high-power rf sources, is very expensive; therefore, we have developed a field-programmable gate array (FPGA-based cavity simulator as a substitute for real rf cavities. Digital models of the cavity and other rf systems are implemented in the FPGA. The main components include cavity baseband models for the fundamental and parasitic modes, a mechanical model of the Lorentz force detuning, and a model of the beam current. Furthermore, in our simulator, the disturbance model used to simulate the power-supply ripples and microphonics is also carefully considered. Based on the presented cavity simulator, we have established an LLRF system test bench that can be applied to different cavity operational conditions. The simulator performance has been verified by comparison with real cavities in KEK accelerators. In this paper, the development and implementation of this cavity simulator is presented first, and the LLRF test bench based on the presented simulator is constructed. The results are then compared with those for KEK accelerators. Finally, several LLRF applications of the cavity simulator are illustrated.

  19. Technology Transfer: From the Research Bench to Commercialization

    Directory of Open Access Journals (Sweden)

    Gail A. Van Norman, MD

    2017-02-01

    Full Text Available Summary: Progress in medicine hinges on the successful translation of basic science discoveries into new medical devices, diagnostics, and therapeutics. “Technology transfer” is the process by which new innovations flow from the basic research bench to commercial entities and then to public use. In academic institutions, intellectual property rights do not usually fall automatically to the individual inventor per se, but most often are the property of the institution. Technology transfer offices are tasked with seeing to it that such intellectual property rights are properly managed and commercialized. This 2-part series explores the technology transfer process from invention to commercialization. Part 1 reviews basic aspects of intellectual property rights, primarily patents and copyrights. Part 2 will discuss the ways in which inventions become commercialized through startup companies and licensing arrangements with industry players. Key Words: copyright, intellectual property, patent, technology transfer

  20. W5″ Test: A simple method for measuring mean power output in the bench press exercise.

    Science.gov (United States)

    Tous-Fajardo, Julio; Moras, Gerard; Rodríguez-Jiménez, Sergio; Gonzalo-Skok, Oliver; Busquets, Albert; Mujika, Iñigo

    2016-11-01

    The aims of the present study were to assess the validity and reliability of a novel simple test [Five Seconds Power Test (W5″ Test)] for estimating the mean power output during the bench press exercise at different loads, and its sensitivity to detect training-induced changes. Thirty trained young men completed as many repetitions as possible in a time of ≈5 s at 25%, 45%, 65% and 85% of one-repetition maximum (1RM) in two test sessions separated by four days. The number of repetitions, linear displacement of the bar and time needed to complete the test were recorded by two independent testers, and a linear encoder was used as the criterion measure. For each load, the mean power output was calculated in the W5″ Test as mechanical work per time unit and compared with that obtained from the linear encoder. Subsequently, 20 additional subjects (10 training group vs. 10 control group) were assessed before and after completing a seven-week training programme designed to improve maximal power. Results showed that both assessment methods correlated highly in estimating mean power output at different loads (r range: 0.86-0.94; p bench press exercise in subjects who have previous resistance training experience.

  1. Reliability assessment of ballistic jump squats and bench throws.

    Science.gov (United States)

    Alemany, Joseph A; Pandorf, Clay E; Montain, Scott J; Castellani, John W; Tuckow, Alexander P; Nindl, Bradley C

    2005-02-01

    The purpose of this investigation was to determine the test-retest reliability and coefficient of variation of 2 novel physical performance tests. Ten healthy men (22.0 +/- 3.0 years, 87.0 +/- 8.0 kg, 20.0 +/- 5.0% body fat) performed 30 continuous and dynamic jump squats (JS) and bench throws (BT) on 4 separate occasions. The movements were performed under loaded conditions utilizing 30% of subject's predetermined 1 repetition maximum in the back squat and bench press. Mean power (MP; W), peak power (PP; W), mean velocity (MV; m.s(-1)), peak velocity (PV; m.s(-1)), and total work (TW; J) were assessed using a ballistic measurement system (Innervations Inc., Muncie, IN). Data were analyzed using repeated measures analysis of variance with Duncan's post hoc test when mean differences were p < or = 0.05. Intraclass correlation coefficient (ICC) and within-subject coefficient of variation (CV%) were also calculated. All values are presented as mean +/- SE. BT variables were statistically similar across the 4 sessions: MP (350.0 +/- 13.9 W), PP (431.4 +/- 18.5 W) MV (1.6 +/- 0.03 m.s(-1)), PV (2.0 +/- 0.03 m.s(-1)), and TW (199.1 +/- 7.2 J). For JS, session 3 PP (1,669.8 +/- 111.2 W) was significantly greater vs. sessions 1, 2, and 4 (1,601.2 +/- 58.4 W). Session 4 MP (1,403.2 +/- 88.6 W) and MV (1.9 +/- 0.1 m.s(-1)) for JS were significantly lower during sessions 1, 2, and 3 (MP: 1,479.4.5 +/- 44.8 W, MV: 2.0 +/- 0.05 m.s(-1)). TW (834.7 +/- 24.3 J) and PV (2.2 +/- 0.04 m.s(-1)) were statistically similar during all sessions for JS. The CVs ranged from 3.0 to 7.6% for the BT and 3.2 to 5.7% for the JS. ICCs for MP, PP, MV, PV, and TW were 0.92, 0.95, 0.94, 0.91, and 0.95, respectively, during BT. ICCs during JS for MP, PP, MV, PV, and TW were 0.96, 0.98, 0.94, 0.94, and 0.89, respectively. The results of the current study support the use of a 30 continuous and dynamic BT protocol as a reliable upper-body physical performance test, which can be administered with

  2. Numerical simulation of groundwater movement and managed aquifer recharge from Sand Hollow Reservoir, Hurricane Bench area, Washington County, Utah

    Science.gov (United States)

    Marston, Thomas M.; Heilweil, Victor M.

    2012-01-01

    The Hurricane Bench area of Washington County, Utah, is a 70 square-mile area extending south from the Virgin River and encompassing Sand Hollow basin. Sand Hollow Reservoir, located on Hurricane Bench, was completed in March 2002 and is operated primarily as a managed aquifer recharge project by the Washington County Water Conservancy District. The reservoir is situated on a thick sequence of the Navajo Sandstone and Kayenta Formation. Total recharge to the underlying Navajo aquifer from the reservoir was about 86,000 acre-feet from 2002 to 2009. Natural recharge as infiltration of precipitation was approximately 2,100 acre-feet per year for the same period. Discharge occurs as seepage to the Virgin River, municipal and irrigation well withdrawals, and seepage to drains at the base of reservoir dams. Within the Hurricane Bench area, unconfined groundwater-flow conditions generally exist throughout the Navajo Sandstone. Navajo Sandstone hydraulic-conductivity values from regional aquifer testing range from 0.8 to 32 feet per day. The large variability in hydraulic conductivity is attributed to bedrock fractures that trend north-northeast across the study area.A numerical groundwater-flow model was developed to simulate groundwater movement in the Hurricane Bench area and to simulate the movement of managed aquifer recharge from Sand Hollow Reservoir through the groundwater system. The model was calibrated to combined steady- and transient-state conditions. The steady-state portion of the simulation was developed and calibrated by using hydrologic data that represented average conditions for 1975. The transient-state portion of the simulation was developed and calibrated by using hydrologic data collected from 1976 to 2009. Areally, the model grid was 98 rows by 76 columns with a variable cell size ranging from about 1.5 to 25 acres. Smaller cells were used to represent the reservoir to accurately simulate the reservoir bathymetry and nearby monitoring wells; larger

  3. A systematic review of surface electromyography analyses of the bench press movement task

    Science.gov (United States)

    Gołaś, Artur; Blazek, Dusan; Maszczyk, Adam; Wilk, Michał; Pietraszewski, Przemysław; Petr, Miroslav; Uhlir, Petr; Zając, Adam

    2017-01-01

    Background The bench press exercise (BP) plays an important role in recreational and professional training, in which muscle activity is an important multifactorial phenomenon. The objective of this paper is to systematically review electromyography (EMG) studies performed on the barbell BP exercise to answer the following research questions: Which muscles show the greatest activity during the flat BP? Which changes in muscle activity are related to specific conditions under which the BP movement is performed? Strategy PubMed, Scopus, Web of Science and Cochrane Central Register of Controlled Trials (CENTRAL) in the Cochrane Library were searched through June 10, 2016. A combination of the following search terms was used: bench press, chest press, board press, test, measure, assessment, dynamometer, kinematics and biomechanics. Only original, full-text articles were considered. Results The search process resulted in 14 relevant studies that were included in the discussion. The triceps brachii (TB) and pectoralis major (PM) muscles were found to have similar activity during the BP, which was significantly higher than the activity of the anterior deltoid. During the BP movement, muscle activity changes with exercise intensity, velocity of movement, fatigue, mental focus, movement phase and stability conditions, such as bar vibration or unstable surfaces. Under these circumstances, TB is the most common object of activity change. Conclusions PM and TB EMG activity is more dominant and shows greater EMG amplitude than anterior deltoid during the BP. There are six factors that can influence muscle activity during the BP; however, the most important factor is exercise intensity, which interacts with all other factors. The research on muscle activity in the BP has several unresolved areas, such as clearly and strongly defined guidelines to perform EMG measurements (e.g., how to elaborate with surface EMG limits) or guidelines for the use of exact muscle models. PMID

  4. A systematic review of surface electromyography analyses of the bench press movement task.

    Directory of Open Access Journals (Sweden)

    Petr Stastny

    Full Text Available The bench press exercise (BP plays an important role in recreational and professional training, in which muscle activity is an important multifactorial phenomenon. The objective of this paper is to systematically review electromyography (EMG studies performed on the barbell BP exercise to answer the following research questions: Which muscles show the greatest activity during the flat BP? Which changes in muscle activity are related to specific conditions under which the BP movement is performed?PubMed, Scopus, Web of Science and Cochrane Central Register of Controlled Trials (CENTRAL in the Cochrane Library were searched through June 10, 2016. A combination of the following search terms was used: bench press, chest press, board press, test, measure, assessment, dynamometer, kinematics and biomechanics. Only original, full-text articles were considered.The search process resulted in 14 relevant studies that were included in the discussion. The triceps brachii (TB and pectoralis major (PM muscles were found to have similar activity during the BP, which was significantly higher than the activity of the anterior deltoid. During the BP movement, muscle activity changes with exercise intensity, velocity of movement, fatigue, mental focus, movement phase and stability conditions, such as bar vibration or unstable surfaces. Under these circumstances, TB is the most common object of activity change.PM and TB EMG activity is more dominant and shows greater EMG amplitude than anterior deltoid during the BP. There are six factors that can influence muscle activity during the BP; however, the most important factor is exercise intensity, which interacts with all other factors. The research on muscle activity in the BP has several unresolved areas, such as clearly and strongly defined guidelines to perform EMG measurements (e.g., how to elaborate with surface EMG limits or guidelines for the use of exact muscle models.

  5. A systematic review of surface electromyography analyses of the bench press movement task.

    Science.gov (United States)

    Stastny, Petr; Gołaś, Artur; Blazek, Dusan; Maszczyk, Adam; Wilk, Michał; Pietraszewski, Przemysław; Petr, Miroslav; Uhlir, Petr; Zając, Adam

    2017-01-01

    The bench press exercise (BP) plays an important role in recreational and professional training, in which muscle activity is an important multifactorial phenomenon. The objective of this paper is to systematically review electromyography (EMG) studies performed on the barbell BP exercise to answer the following research questions: Which muscles show the greatest activity during the flat BP? Which changes in muscle activity are related to specific conditions under which the BP movement is performed? PubMed, Scopus, Web of Science and Cochrane Central Register of Controlled Trials (CENTRAL) in the Cochrane Library were searched through June 10, 2016. A combination of the following search terms was used: bench press, chest press, board press, test, measure, assessment, dynamometer, kinematics and biomechanics. Only original, full-text articles were considered. The search process resulted in 14 relevant studies that were included in the discussion. The triceps brachii (TB) and pectoralis major (PM) muscles were found to have similar activity during the BP, which was significantly higher than the activity of the anterior deltoid. During the BP movement, muscle activity changes with exercise intensity, velocity of movement, fatigue, mental focus, movement phase and stability conditions, such as bar vibration or unstable surfaces. Under these circumstances, TB is the most common object of activity change. PM and TB EMG activity is more dominant and shows greater EMG amplitude than anterior deltoid during the BP. There are six factors that can influence muscle activity during the BP; however, the most important factor is exercise intensity, which interacts with all other factors. The research on muscle activity in the BP has several unresolved areas, such as clearly and strongly defined guidelines to perform EMG measurements (e.g., how to elaborate with surface EMG limits) or guidelines for the use of exact muscle models.

  6. A top-down system engineering approach as an alternative to the tradiotinal over-the-bench methodology for the design of a building

    NARCIS (Netherlands)

    Bluyssen, P.M.; Oostra, M.A.R.; Böhms, H.M.

    2010-01-01

    The traditional over-the-bench methodology for the design of a building is resulting in failure costs, failures at delivery and severe problems. An interactive top-down approach is required, both for the communication process necessary to facilitate the design, construction, maintenance and

  7. A metronome for controlling the mean velocity during the bench press exercise.

    Science.gov (United States)

    Moras, Gerard; Rodríguez-Jiménez, Sergio; Busquets, Albert; Tous-Fajardo, Julio; Pozzo, Marco; Mujika, Iñigo

    2009-05-01

    Lifting velocity may have a great impact on strength training-induced adaptations. The purpose of this study was to validate a method including a metronome and a measurement tape as inexpensive tools for the estimation of mean lifting velocity during the bench press exercise. Fifteen subjects participated in this study. After determining their one repetition maximum (1RM) load, we estimated the maximum metronome rhythm (R) that each subject could maintain in the concentric phase for loads of 40 and 60% of 1RM. To estimate R, the 3 repetitions with highest concentric power, as measured by means of a linear encoder, were selected, and their average duration was calculated and converted to lifting rhythm in beats per minute (bpm) for each subject. The range of motion was measured using a regular tape and kept constant during all exercises. Subjects were instructed to begin with the barbell at arm lengths and lower it in correspondence with the metronome beep. They subsequently performed 5 repetitions at 3 different rhythms relative to R (50, 70, and 90% R) for each training load (40 and 60% of 1RM). A linear encoder was attached to the bar and used as a criterion to measure the vertical displacement over time. For each rhythm, the mean velocity was calculated with the metronome (time) and the reference distance and compared with that recorded by the linear encoder. The SEM for velocity between both testing methods ranged from 0.02 to 0.05 m.s (coefficient of variation, 4.0-6.4%; Pearson's correlation, 0.8-0.95). The present results showed that the use of a metronome and a measurement tape may be a valid method to estimate the mean velocity of execution during the bench press exercise. This simple method could help coaches and athletes achieve their strength training goals, which are partly determined by lifting velocity.

  8. Case Study Analysis of Linear Chirp and Multitones (OFDM) Radar Signals Through Simulations and Measurement with HYCAM-Research Test Bench

    OpenAIRE

    Le Kernec, Julien; Dreuillet, Philippe; Bobillot, Gerard; Garda, Patrick; Romain, Olivier; Denoulet, Julien

    2009-01-01

    This paper presents a experimental platform that allows comparing objectively any radar waveforms. This is realized by equating radar characteristics, using the same test-bench HYCAM-Research, the same signal processing and also insuring the reproducibility of the experiments. The experimental measurements on linear chirp and multitones are analyzed through distance and velocity imaging.

  9. Characterization of the Stabilized Test Bench of Nulling Interferometry PERSÉE

    Science.gov (United States)

    Lozi, Julien; Ollivier, M.; Cassaing, F.; Le Duigou, J.; CNES; Onera/Dota/HRA; IAS; LESIA; OCA; TAS

    2013-01-01

    There are two problems with the observation of exoplanets: the contrast between the planet and the star and their very low separation. One technique solving these problems is nulling interferometry: two pupils are recombined to make a destructive interference on the star, and their base is adjusted to create a constructive interference on the planet. However, to ensure a sufficient extinction of the star, the optical path difference between the beams must be around the nanometer, and the pointing must be better than one hundredth of Airy disk, despite the external disturbances.To validate the critical points of such a space mission, a laboratory demonstrator, PERSÉE, was defined by a consortium led by the french space agency CNES, including IAS, LESIA, ONERA, OCA and Thales Alenia Space and integrated in Paris Observatory. This bench simulates the entire space mission (interferometer and nanometric cophasing system). Its goal is to deliver and maintain an extinction of 10^-4 stable at better than 10^-5 over a few hours in the presence of typical injected disturbances.My thesis work consisted in integrating the bench in successive stages and to develop calibration procedures. This helped me to characterize the critical elements separately before grouping them. After having implemented the control loops of the cophasing system, their precise analysis helped me to reduce down to 0.3 nm rms the residual OPD, and 0.4 % of the Airy disk the residual tip/tilt, despite disturbances of tens of nanometers, consisting of several tens of vibrational frequencies between 1 and 100 Hz. This has been achieved by the implementation of a linear quadratic Gaussian controller, parameterized by the preliminary measurement of the disturbance to minimize. Thanks to these excellent results, I obtained on the band [1.65 - 2.45] µm a record null rate of 8.8x10^-6 stabilized at 9x10^-7 over a few hours, a decade better than the original specifications. An extrapolation of these results to

  10. Use of a Combination of Vertical and Horizontal Boreholes in Massive Blasting of Benches in the Surface Quarry Rodež

    Directory of Open Access Journals (Sweden)

    Tori Matija

    2017-12-01

    Full Text Available This article deals with the extraction of minerals (limestone/marl/flysch in the quarry Rodež, which is located in western Slovenia. During the extraction of minerals in a quarry, drilling and blasting of benches are used. The focus of the article is on the analysis of the parameters related to drilling and blasting in surface excavations when using a combination of explosions and introducing horizontal wells along with vertical holes in the bench. On the basis of the analysis of basic parameters through a combination of drilling horizontal wells and charging those with the ammonal + Anfex explosive, analyses of effects of seismic disturbances on potentially affected buildings have also been conducted. The article is connected to and deals exclusively with the basic parameters of drilling and blasting, with the introduction of horizontal drilling and with the analysis of seismic measurements of threatened buildings in accordance with the German standard German Institute for Standardisation (DIN 4150 during the use of a new method of blasting.

  11. Oxygen-controlled Biosurfactant Production in a Bench Scale Bioreactor

    Science.gov (United States)

    de Kronemberger, Frederico Araujo; Anna, Lidia Maria Melo Santa; Fernandes, Ana Carolina Loureiro Brito; de Menezes, Reginaldo Ramos; Borges, Cristiano Piacsek; Freire, Denise Maria Guimarães

    Rhamnolipids have been pointed out as promising biosurfactants. The most studied microorganisms for the aerobic production of these molecules are the bacteria of the genus Pseudomonas. The aim of this work was to produce a rhamnolipid-type biosurfactant in a bench-scale bioreactor by one strain of Pseudomonas aeruginosa isolated from oil environments. To study the microorganism growth and production dependency on oxygen, a nondispersive oxygenation device was developed, and a programmable logic controller (PLC) was used to set the dissolved oxygen (DO) concentration. Using the data stored in a computer and the predetermined characteristics of the oxygenation device, it was possible to evaluate the oxygen uptake rate (OUR) and the specific OUR (SOUR) of this microorganism. These rates, obtained for some different DO concentrations, were then compared to the bacterial growth, to the carbon source consumption, and to the rhamnolipid and other virulence factors production. The SOUR presented an initial value of about 60.0 mg02/gdw h. Then, when the exponential growth phase begins, there is a rise in this rate. After that, the SOUR reduces to about 20.0 mg02/gdw h. The carbon source consumption is linear during the whole process.

  12. A kinetic and Kinematic analysis in two assessment situation with bench press. Free Weight vs Smith Machine. Project pilot.

    Directory of Open Access Journals (Sweden)

    I. J. Bautista

    2012-06-01

    Full Text Available This pilot study examines the most relevant kinetic and kinematics variables in two bench press exercises; Smith Machine (PMS vs. free weights (PBL. Two trained subjects participated in the research following informed consent. To determine the maximum load (1-RM, two incremental protocols were used for PMS and PBL. Subject 1 (S-1 produced force values of 770N and 837N, peak force of 28ms and 12ms, in PBL and PMS respectively. Values for subject 2 (S-2 were 693N and 849N, PMF of 60ms and 66ms for PBL and PMS respectively. Detailed analyses of the following variables were performed; velocity curves for each load, the “sticking period”, the distances of grip width, and changes in bar inclination during the ascent phase of the lift were examined. The key findings of this research, and the basis for future research demonstrate that PBL is recommended as a training exercise, while more reliable information regarding force variables can be attained through using PMS in measurement sessions. Key Words: Bench Press, smith machine, free weight, strength assessment, upper limb.

  13. Experimental and modelling studies on continuous synthesis and refining of biodiesel in a dedicated bench scale unit using centrifugal contactor separator technology

    NARCIS (Netherlands)

    Abduh, Muhammad Yusuf; Martinez, Alberto Fernandez; Kloekhorst, Arjan; Manurung, Robert; Heeres, Hero J.

    Continuous synthesis and refining of biodiesel (FAME) using a laboratory scale bench scale unit was explored. The unit consists of three major parts: (i) a continuous centrifugal contactor separator (CCCS) to perform the reaction between sunflower oil and methanol; (ii) a washing unit for the crude

  14. Electrokinetic soil decontamination - summary of results of various studies in laboratory, bench-scale and field

    Energy Technology Data Exchange (ETDEWEB)

    Kutschan, B.; Wutzler, R.; Goldmann, T. [INTUS Inst. fuer Technologie und Umweltschutz e.V., Berlin (Germany)

    2001-07-01

    In electroremediation, contaminants are removed form soil and groundwater by the action of an electric potential applied across electrodes embedded in the contaminated medium. Driving the remediation are the electrokinetic phenomena of electro-osmosis, ion migration and electrophoresis. Other common physicochemical phenomena that are also present are diffusion, chemical reactions, hydrolysis (change of pH-value), ion exchange, complexation and others. The complex interactions between all these phenomena determine the processes. Important process parameters are transition rates, bulk liquid velocity, {zeta}-potential (Helmholtz-Smoluchowski-equation) and others. Some parameters are determined at laboratory-, bench- and field scale. (orig.)

  15. VALIDITY OF A COMMERCIAL LINEAR ENCODER TO ESTIMATE BENCH PRESS 1 RM FROM THE FORCE-VELOCITY RELATIONSHIP

    Directory of Open Access Journals (Sweden)

    Laurent Bosquet

    2010-09-01

    Full Text Available The aim of this study was to assess the validity and accuracy of a commercial linear encoder (Musclelab, Ergotest, Norway to estimate Bench press 1 repetition maximum (1RM from the force - velocity relationship. Twenty seven physical education students and teachers (5 women and 22 men with a heterogeneous history of strength training participated in this study. They performed a 1 RM test and a force - velocity test using a Bench press lifting task in a random order. Mean 1 RM was 61.8 ± 15.3 kg (range: 34 to 100 kg, while 1 RM estimated by the Musclelab's software from the force-velocity relationship was 56.4 ± 14.0 kg (range: 33 to 91 kg. Actual and estimated 1 RM were very highly correlated (r = 0.93, p<0.001 but largely different (Bias: 5.4 ± 5.7 kg, p < 0.001, ES = 1.37. The 95% limits of agreement were ±11.2 kg, which represented ±18% of actual 1 RM. It was concluded that 1 RM estimated from the force-velocity relationship was a good measure for monitoring training induced adaptations, but also that it was not accurate enough to prescribe training intensities. Additional studies are required to determine whether accuracy is affected by age, sex or initial level.

  16. Final PHP bench-scale report for the DOE-ID/SAIC sole source contract

    International Nuclear Information System (INIS)

    1997-04-01

    The Plasma Hearth Process (PHP) Technology Development Project was established to develop, test, and evaluate a new concept for treating mixed waste. The new concept uses direct current (dc) transferred-arc plasma torch technology to process mixed waste into a glass-like end-product. Under the cognizance of the US Department of Energy (DOE) Office of Technology Development (OTD) Mixed Waste Focus Area (MWFA), the technology is being explored for its potential to treat mixed waste. Because it is a mature technology, well-understood and commercially available, it is expected to develop rapidly in this new application. This report summarizes the radioactive bench-scale system activities funded under PHP Sole Source Contract DE-AC07-94ID13266 through the end of the contract

  17. Mechanisms of Inflammation in Proliferative Vitreoretinopathy: From Bench to Bedside

    Directory of Open Access Journals (Sweden)

    Stavros N. Moysidis

    2012-01-01

    Full Text Available Proliferative vitreoretinopathy (PVR is a vision-threatening disease and a common complication of surgery to correct rhegmatogenous retinal detachment (RRD. Several models of the pathogenesis of this disease have been described with some of these models focusing on the role of inflammatory cells and other models focusing on the role of growth factors and cytokines in the vitreous which come into contact with intraretinal and retinal pigment epithelial cells. New experiments have shed light on the pathogenesis of PVR and offer promising avenues for clinical intervention before PVR develops. One such target is the indirect pathway of activation of platelet-derived growth factor receptor alpha (PDGRα, which plays an important role in PVR. Clinical trials assessing the efficacy of 5-fluorouracil (5-FU and low-molecular-weight heparin (LMWH, daunorubicin, and 13-cis-retinoic acid, among other therapies, have yielded mixed results. Here we review inflammatory and other mechanisms involved in the pathogenesis of PVR, we highlight important clinical trials, and we discuss how findings at the bench have the potential to be translated to the bedside.

  18. Effect of different pushing speeds on bench press.

    Science.gov (United States)

    Padulo, J; Mignogna, P; Mignardi, S; Tonni, F; D'Ottavio, S

    2012-05-01

    The purpose of this study was to investigate the effect on muscular strength after a 3-week training with the bench-press at a fixed pushing of 80-100% maximal speed (FPS) and self-selected pushing speed (SPS). 20 resistance-trained subjects were divided at random in 2 groups differing only regarding the pushing speed: in the FPS group (n=10) it was equal to 80-100% of the maximal speed while in the SPS group (n=10) the pushing speed was self-selected. Both groups were trained twice a week for 3 weeks with a load equal to 85% of 1RM and monitored with the encoder. Before and after the training we measured pushing speed and maximum load. Significant differences between and within the 2 groups were pointed out using a 2-way ANOVA for repeated measures. After 3 weeks a significant improvement was shown especially in the FPS group: the maximum load improved by 10.20% and the maximal speed by 2.22%, while in the SPS group the effect was <1%. This study shows that a high velocity training is required to increase the muscle strength further in subjects with a long training experience and this is possible by measuring the individual performance speed for each load. © Georg Thieme Verlag KG Stuttgart · New York.

  19. A Pulsed Electric Field (PEF) bench static system to study bacteria inactivation

    International Nuclear Information System (INIS)

    Cortese, Pietro; Dellacasa, Giuseppe; Gemme, Roberto; Bonetta, Sara; Bonetta, Silvia; Carraro, Elisabetta; Motta, Francesca; Paganoni, Marco; Pizzichemi, Marco

    2011-01-01

    Pulsed Electric Fields (PEF) technology is a promising non-thermal processing method for inactivation of microorganisms. A small PEF bench system able to treat a 0.4 ml static liquid volume has been built and tested at the laboratories of the Universita del Piemonte Orientale in Alessandria, Italy. The technique used to produce the required fields consists of charging high voltage cables of various lengths and subsequently discharge them on a cylindrical cell. The pulse intensity can be adjusted to reach a maximum electric field in the cell of about 35 kV/cm and the pulse frequency can reach 10 Hz. We describe the PEF system in some detail and, as a benchmark of its performances, we report preliminary results obtained on Escherichia coli (ATCC 25922) at 10 9 Cfu/ml concentration suspended in a McIlvaine buffer (pH 7.2).

  20. Development of the virtual experimental bench on the basis of modernized research centrifugal compressor stage test unit with the 3D impeller.

    Science.gov (United States)

    Aksenov, A. A.; Danilishin, A. M.; Dubenko, A. M.; Kozhukov, Y. V.

    2017-08-01

    Design modernization of the centrifugal compressor stage test bench with three dimensional impeller blades was carried out for the possibility of holding a series of experimental studies of different 3D impeller models. The studies relates to the problem of joint work of the impeller and the stationary channels of the housing when carrying out works on modernization with the aim of improving the parameters of the volumetric capacity or pressure in the presence of design constraints. The object of study is the experimental single end centrifugal compressor stage with the 3D impeller. Compressor stage consists of the 3D impeller, vaneless diffuser (VLD), outlet collector - folded side scroll and downstream pipe. The drive is a DC motor 75 kW. The increase gear (multiplier) was set between the compressor and DC motor, gear ratio is i = 9.8. To obtain the characteristics of the compressor and the flow area the following values were measured: total pressure, static pressure, direction (angles) of the stream in different cross sections. Additional pneumometric probes on the front wall of the VLD of the test bench have been installed. Total pressure probes and foster holes for the measurement of total and static pressure by the new drainage scheme. This allowed carrying out full experimental studies for two elements of centrifugal compressor stage. After the experimental tests the comprehensive information about the performance of model stage were obtained. Was measured geometric parameters and the constructed virtual model of the experimental bench flow part with the help of Creo Parametric 3.0 and ANSYS v. 16.2. Conducted CFD calculations and verification with experimental data. Identifies the steps for further experimental and virtual works.

  1. Comparison of force exerted on the sternum during a sneeze versus during low-, moderate-, and high-intensity bench press resistance exercise with and without the valsalva maneuver in healthy volunteers.

    Science.gov (United States)

    Adams, Jenny; Schmid, Jack; Parker, Robert D; Coast, J Richard; Cheng, Dunlei; Killian, Aaron D; McCray, Stephanie; Strauss, Danielle; McLeroy Dejong, Sandra; Berbarie, Rafic

    2014-03-15

    Sternal precautions are intended to prevent complications after median sternotomy, but little data exist to support the consensus recommendations. To better characterize the forces on the sternum that can occur during everyday events, we conducted a prospective nonrandomized study of 41 healthy volunteers that evaluated the force exerted during bench press resistance exercise and while sneezing. A balloon-tipped esophageal catheter, inserted through the subject's nose and advanced into the thoracic cavity, was used to measure the intrathoracic pressure differential during the study activities. After the 1 repetition maximum (1-RM) was assessed, the subject performed the bench press at the following intensities, first with controlled breathing and then with the Valsalva maneuver: 40% of 1-RM (low), 70% of 1-RM (moderate), and 1-RM (high). Next, various nasal irritants were used to induce a sneeze. The forces on the sternum were calculated according to a cylindrical model, and a 2-tailed paired t test was used to compare the mean force exerted during a sneeze with the mean force exerted during each of the 6 bench press exercises. No statistically significant difference was found between the mean force from a sneeze (41.0 kg) and the mean total force exerted during moderate-intensity bench press exercise with breathing (41.4 kg). In conclusion, current guidelines and recommendations limit patient activity after a median sternotomy. Because these patients can repeatedly withstand a sneeze, our study indicates that they can withstand the forces from more strenuous activities than are currently allowed. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. iPSCs: A Minireview from Bench to Bed, including Organoids and the CRISPR System

    Directory of Open Access Journals (Sweden)

    Andrés Javier Orqueda

    2016-01-01

    Full Text Available When Dolly the sheep was born, the first probe into an adult mammalian genome traveling back in time and generating a whole new animal appeared. Ten years later, the reprogramming process became a defined method of producing induced pluripotent stem cells (iPSCs through the overexpression of four transcription factors. iPSCs are capable of originating virtually all types of cells and tissues, including a whole new animal. The reprogramming strategies based on patient-derived cells should make the development of clinical applications of cell based therapy much more straightforward. Here, we analyze the current state, opportunities, and challenges of iPSCs from bench to bed, including organoids and the CRISPR system.

  3. Performance evaluation of the DCMD desalination process under bench scale and large scale module operating conditions

    KAUST Repository

    Francis, Lijo

    2014-04-01

    The flux performance of different hydrophobic microporous flat sheet commercial membranes made of poly tetrafluoroethylene (PTFE) and poly propylene (PP) was tested for Red Sea water desalination using the direct contact membrane distillation (DCMD) process, under bench scale (high δT) and large scale module (low δT) operating conditions. Membranes were characterized for their surface morphology, water contact angle, thickness, porosity, pore size and pore size distribution. The DCMD process performance was optimized using a locally designed and fabricated module aiming to maximize the flux at different levels of operating parameters, mainly feed water and coolant inlet temperatures at different temperature differences across the membrane (δT). Water vapor flux of 88.8kg/m2h was obtained using a PTFE membrane at high δT (60°C). In addition, the flux performance was compared to the first generation of a new locally synthesized and fabricated membrane made of a different class of polymer under the same conditions. A total salt rejection of 99.99% and boron rejection of 99.41% were achieved under extreme operating conditions. On the other hand, a detailed water characterization revealed that low molecular weight non-ionic molecules (ppb level) were transported with the water vapor molecules through the membrane structure. The membrane which provided the highest flux was then tested under large scale module operating conditions. The average flux of the latter study (low δT) was found to be eight times lower than that of the bench scale (high δT) operating conditions.

  4. Performance evaluation of the DCMD desalination process under bench scale and large scale module operating conditions

    KAUST Repository

    Francis, Lijo; Ghaffour, NorEddine; Alsaadi, Ahmad Salem; Nunes, Suzana Pereira; Amy, Gary L.

    2014-01-01

    The flux performance of different hydrophobic microporous flat sheet commercial membranes made of poly tetrafluoroethylene (PTFE) and poly propylene (PP) was tested for Red Sea water desalination using the direct contact membrane distillation (DCMD) process, under bench scale (high δT) and large scale module (low δT) operating conditions. Membranes were characterized for their surface morphology, water contact angle, thickness, porosity, pore size and pore size distribution. The DCMD process performance was optimized using a locally designed and fabricated module aiming to maximize the flux at different levels of operating parameters, mainly feed water and coolant inlet temperatures at different temperature differences across the membrane (δT). Water vapor flux of 88.8kg/m2h was obtained using a PTFE membrane at high δT (60°C). In addition, the flux performance was compared to the first generation of a new locally synthesized and fabricated membrane made of a different class of polymer under the same conditions. A total salt rejection of 99.99% and boron rejection of 99.41% were achieved under extreme operating conditions. On the other hand, a detailed water characterization revealed that low molecular weight non-ionic molecules (ppb level) were transported with the water vapor molecules through the membrane structure. The membrane which provided the highest flux was then tested under large scale module operating conditions. The average flux of the latter study (low δT) was found to be eight times lower than that of the bench scale (high δT) operating conditions.

  5. The effects of superset configuration on kinetic, kinematic, and perceived exertion in the barbell bench press.

    Science.gov (United States)

    Weakley, Jonathon Js; Till, Kevin; Read, Dale B; Phibbs, Padraic J; Roe, Gregory; Darrall-Jones, Joshua; Jones, Ben L

    2017-08-04

    Training that is efficient and effective is of great importance to an athlete. One method of improving efficiency is by incorporating supersets into resistance training routines. However, the structuring of supersets is still unexplored. Therefore, the purpose of this study was to assess the effects of agonist-antagonist (A-A), alternate peripheral (A-P), and similar biomechanical (SB) superset configurations on rate of perceived exertion (RPE), kinetic and kinematic changes during the bench press. 10 subjects performed resistance training protocols in a randomized-crossover design, with magnitude-based inferences assessing changes/differences within and between protocols. Changes in RPE were very likely and almost certainly greater in the A-P and SB protocols when compared with the A-A, while all superset protocols had very likely to almost certain reductions in mean velocity and power from baseline. Reductions in mean velocity and power were almost certainly greater in the SB protocol, with differences between the A-A and A-P protocols being unclear. Decreases in peak force were likely and almost certain in the A-A and SB protocols respectively, with changes in A-P being unclear. Differences between these protocols showed likely greater decreases in SB peak forces when compared to A-A, with all other superset comparisons being unclear. This study demonstrates the importance of exercise selection when incorporating supersets into a training routine. It is suggested that the practitioner uses A-A supersets when aiming to improve training efficiency and minimize reductions in kinetic and kinematic output of the agonist musculature while completing the barbell bench press.

  6. Bench-Scale and Pilot-Scale Treatment Technologies for the ...

    Science.gov (United States)

    Coal mine water (CMW) is typically treated to remove suspended solids, acidity, and soluble metals, but high concentrations of total dissolved solids (TDS) have been reported to impact the environment at several CMW discharge points. Consequently, various states have established TDS wastewater regulations and the US EPA has proposed a benchmark conductivity limit to reduce TDS impacts in streams near mining sites. Traditional CMW treatment effectively removes some TDS components, but is not effective in removing major salt ions due to their higher solubility. This paper describes the basic principles, effectiveness, advantages and disadvantages of various TDS removal technologies (adsorption, bioremediation, capacitive deionization, desalination, electro-chemical ion exchange, electrocoagulation, electrodialysis, ion exchange, membrane filtration, precipitation, and reverse osmosis) that have at least been tested in bench- and pilot-scale experiments. Recent discussions about new regulations to include total dissolved solids TDS) limits would propel interest in the TDS removal technologies focused on coal mine water. TDS removal is not a new concept and has been developed using different technologies for a number of applications, but coal mine water has unique characteristics (depending on the site, mining process, and solid-water-oxygen interactions), which make it unlikely to have a single technology predominating over others. What are some novel technolog

  7. Setup of a bench for short time laser flash diffusivity measurement; Mise en place d`un banc de mesure de diffusivite flash laser aux temps courts

    Energy Technology Data Exchange (ETDEWEB)

    Remy, B.; Maillet, D.; Degiovanni, A. [Centre National de la Recherche Scientifique (CNRS), 54 - Vandoeuvre-les-Nancy (France)

    1996-12-31

    In the domain of thermal engineering, new materials have been developed which are characterized by a high thermal diffusivity (5 to 10 times greater than the best usual conductors: gold, copper, silicon..) but also by a small thickness (from few hundreds of microns to few microns). Their time of response is very short (some few milliseconds to some few microseconds) and they are mainly used as heat dissipating materials. The classical thermal diffusivity measurement techniques are unable to analyze the thermal properties of these materials. Therefore, a bench for fast thermal diffusivity measurements has been developed that uses a laser system for the excitation and for the measurement of temperature (infrared detector). In this study, the measurement bench is described and the metrological problems encountered are discussed. (J.S.) 10 refs.

  8. Runoff and sediment generation on bench-terraced hillsides: measurements and up-scaling of a field-based model

    Science.gov (United States)

    van Dijk, A. I. J. M.; Bruijnzeel, L. A.; Vertessy, R. A.; Ruijter, J.

    2005-05-01

    Despite widespread bench-terracing, stream sediment yields from agricultural hillsides in upland West Java remain high. We studied the causes of this lack of effect by combining measurements at different spatial scales using an erosion process model. Event runoff and sediment yield from two 4-ha terraced hillside subcatchments were measured and field surveys of land use, bench-terrace geometry and storage of sediment in the drainage network were conducted for two consecutive years. Runoff was 3.0-3.9% of rainfall and sediment yield was 11-30 t ha-1 yr-1 for different years, subcatchments and calculation techniques. Sediment storage changes in the subcatchment drainage network were less than 2 t ha-1, whereas an additional 0.3-1.5 t ha-1 was stored in the gully between the subcatchment flumes and the main stream. This suggests mean annual sediment delivery ratios of 86-125%, or 80-104% if this additional storage is included. The Terrace Erosion and Sediment Transport (TEST) model developed and validated for the studied environment was parameterized using erosion plot studies, land use surveys and digital terrain analysis to simulate runoff and sediment generation on the terraced hillsides. This resulted in over-estimates of runoff and under-estimates of runoff sediment concentration. Relatively poor model performance was attributed to sample bias in the six erosion plots used for model calibration and unaccounted covariance between important terrain attributes such as slope, infiltration capacity, soil conservation works and vegetation cover.

  9. Influence of different attentional focus on EMG amplitude and contraction duration during the bench press at different speeds.

    Science.gov (United States)

    Calatayud, Joaquin; Vinstrup, Jonas; Jakobsen, Markus D; Sundstrup, Emil; Colado, Juan Carlos; Andersen, Lars L

    2018-05-01

    The purpose of this study was to investigate whether using different focus affects electromyographic (EMG) amplitude and contraction duration during bench press performed at explosive and controlled speeds. Eighteen young male individuals were familiarized with the procedure and performed the one-maximum repetition (1RM) test in the first session. In the second session, participants performed the bench press exercise at 50% of the 1RM with 3 different attentional focuses (regular focus on moving the load vs contracting the pectoralis vs contracting the triceps) at 2 speed conditions (controlled vs maximal speed). During the controlled speed condition, focusing on using either the pectoralis or the triceps muscles increased pectoralis normalized EMG (nEMG) by 6% (95% CI 3-8%; p = 0.0001) and 4% nEMG (95% CI 1-7%; p = 0.0096), respectively, compared with the regular focus condition. Triceps activity was increased by 4% nEMG (95% CI 0-7%; p = 0.0308) at the controlled speed condition during the triceps focus. During the explosive speed condition, the use of different focuses had no effect. The different attentional focus resulted in comparable contraction duration for the measured muscles when the exercise was performed explosively. Using internal focus to increase EMG amplitude seems to function only during conditions of controlled speed.

  10. Thermochemical water-splitting cycle, bench-scale investigations and process engineering. Annual report, October 1, 1978-September 30, 1979

    Energy Technology Data Exchange (ETDEWEB)

    Caprioglio, G.; McCorkle, K.H.; Besenbruch, G.E.; Rode, J.S.

    1980-03-01

    A program to investigate thermochemical water splitting has been under way at General Atomic Company (GA) since October 1972. This document is an annual progress report of Department of Energy (DOE) sponsored process development work on the GA sulfur-iodine thermochemical water splitting cycle. The work consisted of laboratory bench-scale investigations, demonstration of the process in a closed-loop cycle demonstrator, and process engineering design studies. A bench-scale system, consisting of three subunits, has been designed to study the cycle under continuous flow conditions. The designs of subunit I, which models the main solution reaction and product separation, and subunit II, which models the concentration and decomposition of sulfuric acid, were presented in an earlier annual report. The design of subunit III, which models the purification and decomposition of hydrogen iodide, is given in this report. Progress on the installation and operation of subunits I and II is described. A closed-loop cycle demonstrator was installed and operated based on a DOE request. Operation of the GA sulfur-iodine cycle was demonstrated in this system under recycle conditions. The process engineering addresses the flowsheet design of a large-scale production process consisting of four chemical sections (I through IV) and one helium heat supply section (V). The completed designs for sections I through V are presented. The thermal efficiency of the process calculated from the present flowsheet is 47%.

  11. Effect of movement velocity on the relationship between training load and the number of repetitions of bench press.

    Science.gov (United States)

    Sakamoto, Akihiro; Sinclair, Peter J

    2006-08-01

    This study investigated the effect of movement velocity on the relationship between loading intensity and the number of repetitions of bench press. Thirteen healthy men (age = 21.7 +/- 1.0 years; weight = 76.8 +/- 2.5 kg; 1 repetition maximum [1RM] = 99.5 +/- 6.0 kg), who were involved in regular weight training, voluntarily participated in the experiment. Subjects performed bench presses on a Smith machine at 5 different intensities (40-80% 1RM), repeated for 4 velocity conditions (slow: 0.15 +/- 0.03 m.s(-1); medium: 0.32 +/- 0.07 m.s(-1); fast: 0.52 +/- 0.12 m.s(-1); ballistic: maximum velocity), which were randomly assigned over 5 experimental sessions after a 1RM test. Velocity significantly changed the relationship between intensity (%1RM) and the number of reps performed (p velocities producing a higher number of reps. A significant interaction between intensity and velocity meant that velocity had a much greater effect on repetitions at lower intensities. These results suggest that the benefits of using a stretch-shortening cycle during faster movements outweigh the associated disadvantages from the force-velocity relationship. The practical applications of this study are that, when trainees are assigned a resistance training with specific RM values, the lifted intensity (%1RM) or weights will not be consistent unless velocity is controlled during training.

  12. Automation of the positioning of a laser anemometer flow rate measurement bench

    International Nuclear Information System (INIS)

    Gobillot, G.

    1998-01-01

    The laser anemometry technique is commonly used by the Core Hydraulics Laboratory of the CEA for the determination of the field of flow rates inside fuel rod bundles. The adjustment of measurement point coordinates represents an important part of the velocimetry campaign. In order to increase the number of measurements and the preciseness of the positioning operation, the automation of these preliminary tasks was decided. This work describes first the principle of Doppler laser velocimetry, the components of the measurement system and their functioning conditions. Then, the existing software for tuning and measurement is presented. A new software, called PAMELA, for the automatic positioning of the laser anemometer using a moving table with 5 degrees of freedom, has been developed and tested. This software, written with the LabView language, advises the operator, drives the bench and executes the tunings with a greater precision than manually. (J.S.)

  13. Design of the ANTARES LCM-DAQ board test bench using a FPGA-based system-on-chip approach

    Energy Technology Data Exchange (ETDEWEB)

    Anvar, S. [CEA Saclay, DAPNIA/SEDI, 91191 Gif-sur-Yvette Cedex (France); Kestener, P. [CEA Saclay, DAPNIA/SEDI, 91191 Gif-sur-Yvette Cedex (France)]. E-mail: pierre.kestener@cea.fr; Le Provost, H. [CEA Saclay, DAPNIA/SEDI, 91191 Gif-sur-Yvette Cedex (France)

    2006-11-15

    The System-on-Chip (SoC) approach consists in using state-of-the-art FPGA devices with embedded RISC processor cores, high-speed differential LVDS links and ready-to-use multi-gigabit transceivers allowing development of compact systems with substantial number of IO channels. Required performances are obtained through a subtle separation of tasks between closely cooperating programmable hardware logic and user-friendly software environment. We report about our experience in using the SoC approach for designing the production test bench of the off-shore readout system for the ANTARES neutrino experiment.

  14. Surfactant from neonatal to pediatric ICU: bench and bedside evidence.

    Science.gov (United States)

    Boet, A; Brat, R; Aguilera, S S; Tissieres, P; De Luca, D

    2014-12-01

    Surfactant is a cornerstone of neonatal critical care for the treatment of respiratory distress syndrome of preterm babies. However, other indications have been studied for various clinical conditions both in term neonates and in children beyond neonatal age. A high degree of evidence is not yet available in some cases and this is due to the complex and not yet totally understood physiopathology of the different types of pediatric and neonatal lung injury. We here summarise the state of the art of the bench and bedside knowledge about surfactant use for the respiratory conditions usually cared for in neonatal and pediatric intensive care units. Future research direction will also be presented. On the whole, surfactant is able to improve oxygenation in infection related respiratory failure, pulmonary hemorrhage and meconium aspiration syndrome. Bronchoalveolar lavage with surfactant solution is currently the only means to reduce mortality or need for extracorporeal life support in neonates with meconium aspiration. While surfactant bolus or lavage only improves the oxygenation and ventilatory requirements in other types of postneonatal acute respiratory distress syndrome (ARDS), there seems to be a reduction in the mortality of small infants with RSV-related ARDS.

  15. Effect of Bench Press Load Knowledge on Repetitions, Rating of Perceived Exertion, and Attentional Focus.

    Science.gov (United States)

    Beaudoin, Christina M; Cox, Zachary; Dundore, Tyler; Thomas, Tayler; Kim, Johnathon; Pillivant, Daniel

    2018-02-01

    Beaudoin, CM, Cox, Z, Dundore, T, Thomas, T, Kim, J, and Pillivant, D. Effect of bench press load knowledge on repetitions, rating of perceived exertion, and attentional focus. J Strength Cond Res 32(2): 514-519, 2018-Few studies have examined the role of the teleoanticipation during resistance training. The purpose of this study was to examine the effect of bench press (BP) load knowledge on repetitions completed, ratings of perceived exertion (RPEs), and attentional focus (% associative). Thirty-six recreationally active resistance-trained men (n = 25) and women (n = 11) participated in this study (age = 20.97 ± 1.87 years; ht = 174.12 ± 9.41 cm; and mass = 80.14 ± 14.03 kg). All subjects completed 3 testing sessions: (a) 1 repetition maximum (1RM) BP determination; (b) submaximal BP repetitions to fatigue known load (KL); and (c) submaximal BP repetitions to fatigue unknown load (UL). Known load and UL sessions were randomized and counterbalanced and both completed at 70% 1RM. An estimated weight ratio was computed using the subject's estimate of the UL weight relative to the KL weight. An independent samples t-test revealed no significant testing order difference for the estimated weight ratio. Two-way repeated-measures analysis of variances revealed no significant differences in the number of repetitions (p = 0.63), RPE (p = 0.18), or attentional focus (% associative) (p = 0.93) between the KL and UL conditions. Pearson correlations found a moderate positive association between KL repetitions completed and % associative focus when the UL was completed before the KL. Load knowledge did not influence the number of repetitions, RPE, or attentional focus while completing the BP. Further research examining the use of pacing strategies, RPE, and attentional focus during KL and UL conditions are warranted.

  16. Effects of Pre-exhaustion on the Patterns of Muscular Activity in the Flat Bench Press.

    Science.gov (United States)

    Gołaś, Artur; Maszczyk, Adam; Pietraszewski, Przemyslaw; Stastny, Petr; Tufano, James J; Zając, Adam

    2017-07-01

    Gołaś, A, Maszczyk, A, Pietraszewski, P, Stastny, P, Tufano, JJ, and Zając, A. Effects of pre-exhaustion on the patterns of muscular activity in the flat bench press. J Strength Cond Res 31(7): 1919-1924, 2017-Pre-exhaustion (PE) has been applied in resistance training (RT) to manipulate the order of performing 2 resistance exercises, a single-joint exercise to momentary exhaustion, followed by a multi-joint movement that includes the same muscle group. This method ensures greater recruitment of muscles or muscle groups in the multi-joint exercise to further increase muscle strength and overcome strength plateaus. The purpose of the present study was to investigate muscle activity by electromyography during high-intensity (95% of 1 repetition maximum [RM]) bench press (BP), before and after PE of the pectoralis major (PM), anterior deltoid (AD), and triceps brachii (TB) muscles to determine the effects of PE of the prime movers. Eight healthy athletes, experienced in RT, participated in the study. There were 4 sessions in the experiment. Session 1 was aimed at determination of 1RM during a flat BP. Sessions 2, 3, and 4 consisted of performing a BP after PE of the muscles studied by the incline dumbbell fly, front deltoid raise, and lying triceps extension exercise. Peak concentric TB activation after TB PE (mean ± SD, 147.76 ± 18.6%) was significantly greater by analysis of variance (η = 0.82, F = 5.45, p = 0.004) compared with peak TB activation (114.77 ± 19.4%) before TB PE. The statistical analysis for PM and AD did not show any significant differences. Coaches should not expect the usefulness of PE protocol to elicit higher PM or AD activity or fatigue, but they can use it to increase TB activity before high-intensity BP exercise.

  17. A new reference tip-timing test bench and simulator for blade synchronous and asynchronous vibrations

    Science.gov (United States)

    Hajnayeb, Ali; Nikpour, Masood; Moradi, Shapour; Rossi, Gianluca

    2018-02-01

    The blade tip-timing (BTT) measurement technique is at present the most promising technique for monitoring the blades of axial turbines and aircraft engines in operating conditions. It is generally used as an alternative to strain gauges in turbine testing. By conducting a comparison with the standard methods such as those based on strain gauges, one determines that the technique is not intrusive and does not require a complicated installation process. Despite its superiority to other methods, the experimental performance analysis of a new BTT method needs a test stand that includes a reference measurement system (e.g. strain gauges equipped with telemetry or other complex optical measurement systems, like rotating laser Doppler vibrometers). In this article, a new reliable, low-cost BTT test setup is proposed for simulating and analyzing blade vibrations based on kinematic inversion. In the proposed test bench, instead of the blades vibrating, it is the BTT sensor that vibrates. The vibration of the sensor is generated by a shaker and can therefore be easily controlled in terms of frequency, amplitude and waveform shape. The amplitude of vibration excitation is measured by a simple accelerometer. After introducing the components of the simulator, the proposed test bench is used in practice to simulate both synchronous and asynchronous vibration scenarios. Then two BTT methods are used to evaluate the quality of the acquired data. The results demonstrate that the proposed setup is able to generate simulated pulse sequences which are almost the same as those generated by the conventional BTT systems installed around a bladed disk. Moreover, the test setup enables its users to evaluate BTT methods by using a limited number of sensors. This significantly reduces the total costs of the experiments.

  18. The hot bench scale plant Ester for the vitrification of high level wastes

    International Nuclear Information System (INIS)

    Nannicini, R.; Strazzer, A.; Cantale, C; Donato, A.; Grossi, G.

    1985-01-01

    In this paper the hot bench-scale plant ESTER for the vitrification of the high-level radioactive wastes is described, and the main results of the first radioactive campaign are reported. The ESTER plant, which is placed in the ADECO-ESSOR hot cells of the C.C.R.-EURATOM-ISPRA, has been built and is operated by the ENEA, Departement of Fuel Cycle. It began operating with real radioactive wastes about 1 year ago, solidifying a total of 12 Ci of fission products into 2,02 Kg of borosilicate glass, corresponding to 757 ml of glass. During the vitrification many samples of liquid and gaseous streams have been taken and analyzed. A radioactivity balance in the plant has been calculated, as well as a mass balance of nitrates and of the 137 Cs and 106 Ru volatized in the process

  19. DockBench: An Integrated Informatic Platform Bridging the Gap between the Robust Validation of Docking Protocols and Virtual Screening Simulations

    Directory of Open Access Journals (Sweden)

    Alberto Cuzzolin

    2015-05-01

    Full Text Available Virtual screening (VS is a computational methodology that streamlines the drug discovery process by reducing costs and required resources through the in silico identification of potential drug candidates. Structure-based VS (SBVS exploits knowledge about the three-dimensional (3D structure of protein targets and uses the docking methodology as search engine for novel hits. The success of a SBVS campaign strongly depends upon the accuracy of the docking protocol used to select the candidates from large chemical libraries. The identification of suitable protocols is therefore a crucial step in the setup of SBVS experiments. Carrying out extensive benchmark studies, however, is usually a tangled task that requires users’ proficiency in handling different file formats and philosophies at the basis of the plethora of existing software packages. We present here DockBench 1.0, a platform available free of charge that eases the pipeline by automating the entire procedure, from docking benchmark to VS setups. In its current implementation, DockBench 1.0 handles seven docking software packages and offers the possibility to test up to seventeen different protocols. The main features of our platform are presented here and the results of the benchmark study of human Checkpoint kinase 1 (hChk1 are discussed as validation test.

  20. Validity of a Commercial Linear Encoder to Estimate Bench Press 1 RM from the Force-Velocity Relationship.

    Science.gov (United States)

    Bosquet, Laurent; Porta-Benache, Jeremy; Blais, Jérôme

    2010-01-01

    The aim of this study was to assess the validity and accuracy of a commercial linear encoder (Musclelab, Ergotest, Norway) to estimate Bench press 1 repetition maximum (1RM) from the force - velocity relationship. Twenty seven physical education students and teachers (5 women and 22 men) with a heterogeneous history of strength training participated in this study. They performed a 1 RM test and a force - velocity test using a Bench press lifting task in a random order. Mean 1 RM was 61.8 ± 15.3 kg (range: 34 to 100 kg), while 1 RM estimated by the Musclelab's software from the force-velocity relationship was 56.4 ± 14.0 kg (range: 33 to 91 kg). Actual and estimated 1 RM were very highly correlated (r = 0.93, pvelocity relationship was a good measure for monitoring training induced adaptations, but also that it was not accurate enough to prescribe training intensities. Additional studies are required to determine whether accuracy is affected by age, sex or initial level. Key pointsSome commercial devices allow to estimate 1 RM from the force-velocity relationship.These estimations are valid. However, their accuracy is not high enough to be of practical help for training intensity prescription.Day-to-day reliability of force and velocity measured by the linear encoder has been shown to be very high, but the specific reliability of 1 RM estimated from the force-velocity relationship has to be determined before concluding to the usefulness of this approach in the monitoring of training induced adaptations.

  1. Enhanced durability and reactivity for zinc ferrite desulfurization sorbent. Volume 1, Bench-scale testing and analysis

    Energy Technology Data Exchange (ETDEWEB)

    Jha, M.C.; Berggren, M.H.

    1989-05-02

    AMAX Research & Development Center (AMAX R&D) has been investigating methods for enhancing the reactivity and durability of the zinc ferrite desulfurization sorbent. Zinc ferrite sorbents are intended for use in desulfurization of hot coal gas in integrated gasification combined cycle (IGCC) or molten carbonate fuel cell (MCFC) applications. For the present program, the reactivity of the sorbent may be defined as its sulfur sorption capacity at the breakthrough point and at saturation in a bench-scale, fixed-bed reactor. Durability may be defined as the ability of the sorbent to maintain important physical characteristics such As size, strength, and specific surface area during 10 cycles of sulfidation and oxidation.

  2. Treatment of waste gas containing low concentration of dimethyl sulphide (DMS) in a bench-scale biofilter.

    Science.gov (United States)

    Giri, B S; Mudliar, S N; Deshmukh, S C; Banerjee, S; Pandey, R A

    2010-04-01

    Biological treatment of dimethyl sulphide (DMS) was investigated in a bench-scale biofilter, packed with compost along with wood chips, and enriched with DMS degrading microorganism Bacillus sphaericus. The biofilter could remove 62-74% of the inlet DMS, at an optimum loading of 0.484 g/m(3)/h with optimum empty bed contact time (EBCT) of 384 s and an average moisture range of 65-70%. The biodegradative products of DMS were sulphide, thiosulphate and sulphate. Evaluation of microbiological status of the biofilter indicated the presence of other bacterial cultures viz. Paenibacillus polymyxa, and Bacillus megaterium, besides B. sphaericus. Copyright 2009 Elsevier Ltd. All rights reserved.

  3. Design of a new front-end electronics test-bench for the upgraded ATLAS detector's Tile Calorimeter

    International Nuclear Information System (INIS)

    Kureba, C O; Govender, M; Hofsajer, I; Ruan, X; Sandrock, C; Spoor, M

    2015-01-01

    The year 2022 has been scheduled to see an upgrade of the Large Hadron Collider (LHC), in order to increase its instantaneous luminosity. The High Luminosity LHC, also referred to as the upgrade Phase-II, means an inevitable complete re-design of the read-out electronics in the Tile Calorimeter (TileCal) of the A Toroidal LHC Apparatus (ATLAS) detector. Here, the new read-out architecture is expected to have the front-end electronics transmit fully digitized information of the detector to the back-end electronics system. Fully digitized signals will allow more sophisticated reconstruction algorithms which will contribute to the required improved triggers at high pile-up. In Phase II, the current Mobile Drawer Integrity ChecKing (MobiDICK) test-bench will be replaced by the next generation test-bench for the TileCal superdrawers, the new Prometeo (A Portable ReadOut ModulE for Tilecal ElectrOnics). Prometeo is a portable, high-throughput electronic system for full certification of the front-end electronics of the ATLAS TileCal. It is designed to interface to the fast links and perform a series of tests on the data to assess the certification of the electronics. The Prometeo's prototype is being assembled by the University of the Witwatersrand and installed at CERN for further developing, tuning and tests. This article describes the overall design of the new Prometeo, and how it fits into the TileCal electronics upgrade. (paper)

  4. GasBench/isotope ratio mass spectrometry: a carbon isotope approach to detect exogenous CO(2) in sparkling drinks.

    Science.gov (United States)

    Cabañero, Ana I; San-Hipólito, Tamar; Rupérez, Mercedes

    2007-01-01

    A new procedure for the determination of carbon dioxide (CO(2)) (13)C/(12)C isotope ratios, using direct injection into a GasBench/isotope ratio mass spectrometry (GasBench/IRMS) system, has been developed to improve isotopic methods devoted to the study of the authenticity of sparkling drinks. Thirty-nine commercial sparkling drink samples from various origins were analyzed. Values of delta(13)C(cava) ranged from -20.30 per thousand to -23.63 per thousand, when C3 sugar addition was performed for a second alcoholic fermentation. Values of delta(13)C(water) ranged from -5.59 per thousand to -6.87 per thousand in the case of naturally carbonated water or water fortified with gas from the spring, and delta(13)C(water) ranged from -29.36 per thousand to -42.09 per thousand when industrial CO(2) was added. It has been demonstrated that the addition of C4 sugar to semi-sparkling wine (aguja) and industrial CO(2) addition to sparkling wine (cava) or water can be detected. The new procedure has advantages over existing methods in terms of analysis time and sample treatment. In addition, it is the first isotopic method developed that allows (13)C/(12)C determination directly from a liquid sample without previous CO(2) extraction. No significant isotopic fractionation was observed nor any influence by secondary compounds present in the liquid phase. Copyright (c) 2007 John Wiley & Sons, Ltd.

  5. Design of an FPGA-based embedded system for the ATLAS Tile Calorimeter front-end electronics test-bench

    CERN Document Server

    Carrio, F; The ATLAS collaboration; Moreno, P; Reed, R; Sandrock, C; Shalyugin, A; Schettino, V; Solans, C; Souza, J; Usai, G; Valero, A

    2013-01-01

    The portable test bench (VME based) used for the certification of the Tile calorimeter front-end electronics has been redesigned for the LHC Long Shutdown (2013-2014) improving its portability. The new version is based on a Xilinx Virtex 5 FPGA that implements an embedded system using a hard core PowerPC 440 microprocessor and custom IP cores. The PowerPC microprocessor runs a light Linux version and handles the IP cores written in VHDL that implement the different functionalities (TTC, G-Link, CAN-Bus) Description of the system and performance measurements of the different components will be shown.

  6. Radiochemical analyses of surface water from U.S. Geological Survey hydrologic bench-mark stations

    Science.gov (United States)

    Janzer, V.J.; Saindon, L.G.

    1972-01-01

    The U.S. Geological Survey's program for collecting and analyzing surface-water samples for radiochemical constituents at hydrologic bench-mark stations is described. Analytical methods used during the study are described briefly and data obtained from 55 of the network stations in the United States during the period from 1967 to 1971 are given in tabular form.Concentration values are reported for dissolved uranium, radium, gross alpha and gross beta radioactivity. Values are also given for suspended gross alpha radioactivity in terms of natural uranium. Suspended gross beta radioactivity is expressed both as the equilibrium mixture of strontium-90/yttrium-90 and as cesium-137.Other physical parameters reported which describe the samples include the concentrations of dissolved and suspended solids, the water temperature and stream discharge at the time of the sample collection.

  7. Bench calibration of INDUS-2 beam position indicators

    International Nuclear Information System (INIS)

    Tyagi, Y.; Banerji, Anil; Kotaiah, S.

    2005-01-01

    A third generation synchrotron radiation source of energy 2.5 GeV named INDUS-2 at Centre for Advanced Technology (C.A.T), Indore (M.P) is in the advanced stage of construction. Accurate determination and correction of beam closed orbit in INDUS-2 machine within 100 of microns is a very desirable goal. Bench based calibration of Beam Position Indicators (BPI) play a very important and useful role during initial commissioning of electron machines. To precisely measure transverse position of electron beam in the Indus-2 storage ring, 56 Beam Position Indicators (BPI) will be installed in INDUS-2 machine. Out of 56 Beam Position Indicators 40 are of individual type whereas 16 are integrated with dipole vacuum chamber. The Beam Position Indicators are required to be calibrated before they can be installed. The calibration is done to determine electrical offset with respect to defined mechanical centre, to determine displacement sensitivities as well as non linearity's of BPI. Ideally when beam passes through the geometrical center of BPI's, all electrodes should have same signal strength. However due to different capacitance of electrodes and offset and drift in electronics, the electrical centre (mechanical x, y where all electrodes shows same signal strength) differs from mechanical centre of BPI. A fully automatic calibration system has been developed to carry out the calibration of Beam Position Indicators. A calibration software has been developed which has necessary utilities to process and display calibration data and results. This paper describes the calibration results of Indus-2 BPM. (author)

  8. Automated ECU software tests on hardware-in-the-loop test benches; Automatisierte ECU-Software-Tests an Hardware-in-the-Loop-Pruefstaenden

    Energy Technology Data Exchange (ETDEWEB)

    Voegl, R. [AVL List GmbH, Graz (Austria). Abteilung Kalibrierung Ottomotoren; Duerager, Ch. [AVL List GmbH, Graz (Austria). Abteilung Kalibriermethodik; Beer, W.; Martini, E. [AVL List GmbH, Graz (Austria)

    2005-08-01

    Due to the continuous increase in complexity of engine application, AVL List decided to develop methods for automated ECU software commissioning on HiL test benches. This required the intensive co-operation of the departments for calibration methodology, calibration and electrical/electronic engineering. The result is a practical orientated collection of methods that significantly increase the test coverage for a new software version without extending the commissioning time. (orig.)

  9. From the Bench to the Bedside: The Role of Semantic Web and Translational Medicine for Enabling the Next Generation Healthcare Enterprise

    Science.gov (United States)

    Kashyap, Vipul

    The success of new innovations and technologies are very often disruptive in nature. At the same time, they enable novel next generation infrastructures and solutions. These solutions introduce great efficiencies in the form of efficient processes and the ability to create, organize, share and manage knowledge effectively; and the same time provide crucial enablers for proposing and realizing new visions. In this paper, we propose a new vision of the next generation healthcare enterprise and discuss how Translational Medicine, which aims to improve communication between the basic and clinical sciences, is a key requirement for achieving this vision. This will lead therapeutic insights may be derived from new scientific ideas - and vice versa. Translation research goes from bench to bedside, where theories emerging from preclinical experimentation are tested on disease-affected human subjects, and from bedside to bench, where information obtained from preliminary human experimentation can be used to refine our understanding of the biological principles underpinning the heterogeneity of human disease and polymorphism(s). Informatics and semantic technologies in particular, has a big role to play in making this a reality. We identify critical requirements, viz., data integration, clinical decision support and knowledge maintenance and provenance; and illustrate semantics-based solutions wrt example scenarios and use cases.

  10. The hydrologic bench-mark program; a standard to evaluate time-series trends in selected water-quality constituents for streams in Georgia

    Science.gov (United States)

    Buell, G.R.; Grams, S.C.

    1985-01-01

    Significant temporal trends in monthly pH, specific conductance, total alkalinity, hardness, total nitrite-plus-nitrite nitrogen, and total phosphorus measurements at five stream sites in Georgia were identified using a rank correlation technique, the seasonal Kendall test and slope estimator. These sites include a U.S. Geological Survey Hydrologic Bench-Mark site, Falling Creek near Juliette, and four periodic water-quality monitoring sites. Comparison of raw data trends with streamflow-residual trends and, where applicable, with chemical-discharge trends (instantaneous fluxes) shws that some of these trends are responses to factors other than changing streamflow. Percentages of forested, agricultural, and urban cover with each basin did not change much during the periods of water-quality record, and therefore these non-flow-related trends are not obviously related to changes in land cover or land use. Flow-residual water-quality trends at the Hydrologic Bench-Mark site and at the Chattooga River site probably indicate basin reponses to changes in the chemical quality of atmospheric deposition. These two basins are predominantly forested and have received little recent human use. Observed trends at the other three sites probably indicate basin responses to various land uses and water uses associated with agricultural and urban land or to changes in specific uses. (USGS)

  11. The role of resting duration in the kinematic pattern of two consecutive bench press sets to failure in elite sprint kayakers.

    Science.gov (United States)

    García-López, D; Herrero, J A; Abadía, O; García-Isla, F J; Ualí, I; Izquierdo, M

    2008-09-01

    This study aimed to investigate the role of rest period duration (RP) on the time course of the acceleration portion (AP) and mean velocity of the concentric phase across two bench press sets to failure with a submaximal load (60% of the 1RM) using different RP. Ten elite junior kayakers performed, on four different days, two consecutive bench press sets to failure, allowing randomly 1-, 2-, 3- and 4-min RP between sets. AP reached a maximal value of 66% of the concentric movement time. This maximal AP was observed in repetition number 2 or 3, and then AP declined during the set, with a significant decrease when the number of repetitions was over 80% of the total number of repetitions performed. AP and lifting velocity patterns of the concentric phase were not altered during a second set to failure, regardless of RP. However, when velocity was expressed in absolute terms, 1-min RP was insufficient to maintain the average lifting velocity during the second set, compared to the first one. These results may be of use in selecting number of repetitions and resting duration in order to ensure optimal maintenance of the accelerative portion of concentric movement time with different resting-period durations.

  12. Bioprosthetic Valve Fracture During Valve-in-valve TAVR: Bench to Bedside.

    Science.gov (United States)

    Saxon, John T; Allen, Keith B; Cohen, David J; Chhatriwalla, Adnan K

    2018-01-01

    Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) has been established as a safe and effective means of treating failed surgical bioprosthetic valves (BPVs) in patients at high risk for complications related to reoperation. Patients who undergo VIV TAVR are at risk of patient-prosthesis mismatch, as the transcatheter heart valve (THV) is implanted within the ring of the existing BPV, limiting full expansion and reducing the maximum achievable effective orifice area of the THV. Importantly, patient-prosthesis mismatch and high residual transvalvular gradients are associated with reduced survival following VIV TAVR. Bioprosthetic valve fracture (BVF) is as a novel technique to address this problem. During BPV, a non-compliant valvuloplasty balloon is positioned within the BPV frame, and a highpressure balloon inflation is performed to fracture the surgical sewing ring of the BPV. This allows for further expansion of the BPV as well as the implanted THV, thus increasing the maximum effective orifice area that can be achieved after VIV TAVR. This review focuses on the current evidence base for BVF to facilitate VIV TAVR, including initial bench testing, procedural technique, clinical experience and future directions.

  13. Nasal high-frequency oscillatory ventilation impairs heated humidification: A neonatal bench study.

    Science.gov (United States)

    Ullrich, Tim L; Czernik, Christoph; Bührer, Christoph; Schmalisch, Gerd; Fischer, Hendrik S

    2017-11-01

    Nasal high-frequency oscillatory ventilation (nHFOV) is a novel mode of non-invasive ventilation used in neonates. However, upper airway obstructions due to viscous secretions have been described as specific adverse effects. We hypothesized that high-frequency oscillations reduce air humidity in the oropharynx, resulting in upper airway desiccation. Therefore, we aimed to investigate the effects of nHFOV ventilatory settings on oropharyngeal gas conditions. NHFOV or nasal continuous positive airway pressure (nCPAP) was applied, along with heated humidification, to a previously established neonatal bench model that simulates oropharyngeal gas conditions during spontaneous breathing through an open mouth. A digital thermo-hygro sensor measured oropharyngeal temperature (T) and humidity at various nHFOV frequencies (7, 10, 13 Hz), amplitudes (10, 20, 30 cmH 2 O), and inspiratory-to-expiratory (I:E) ratios (25:75, 33:66, 50:50), and also during nCPAP. Relative humidity was always >99%, but nHFOV resulted in lower mean T and absolute humidity (AH) in comparison to nCPAP (P humidification during nHFOV. © 2017 Wiley Periodicals, Inc.

  14. Force-Velocity Relationship of Upper Body Muscles: Traditional Versus Ballistic Bench Press.

    Science.gov (United States)

    García-Ramos, Amador; Jaric, Slobodan; Padial, Paulino; Feriche, Belén

    2016-04-01

    This study aimed to (1) evaluate the linearity of the force-velocity relationship, as well as the reliability of maximum force (F0), maximum velocity (V0), slope (a), and maximum power (P0); (2) compare these parameters between the traditional and ballistic bench press (BP); and (3) determine the correlation of F0 with the directly measured BP 1-repetition maximum (1RM). Thirty-two men randomly performed 2 sessions of traditional BP and 2 sessions of ballistic BP during 2 consecutive weeks. Both the maximum and mean values of force and velocity were recorded when loaded by 20-70% of 1RM. All force-velocity relationships were strongly linear (r > .99). While F0 and P0 were highly reliable (ICC: 0.91-0.96, CV: 3.8-5.1%), lower reliability was observed for V0 and a (ICC: 0.49-0.81, CV: 6.6-11.8%). Trivial differences between exercises were found for F0 (ES: velocity relationship is useful to assess the upper body maximal capabilities to generate force, velocity, and power.

  15. Accuracy improvement in a calibration test bench for accelerometers by a vision system

    International Nuclear Information System (INIS)

    D’Emilia, Giulio; Di Gasbarro, David; Gaspari, Antonella; Natale, Emanuela

    2016-01-01

    A procedure is described in this paper for the accuracy improvement of calibration of low-cost accelerometers in a prototype rotary test bench, driven by a brushless servo-motor and operating in a low frequency range of vibrations (0 to 5 Hz). Vibration measurements by a vision system based on a low frequency camera have been carried out, in order to reduce the uncertainty of the real acceleration evaluation at the installation point of the sensor to be calibrated. A preliminary test device has been realized and operated in order to evaluate the metrological performances of the vision system, showing a satisfactory behavior if the uncertainty measurement is taken into account. A combination of suitable settings of the control parameters of the motion control system and of the information gained by the vision system allowed to fit the information about the reference acceleration at the installation point to the needs of the procedure for static and dynamic calibration of three-axis accelerometers.

  16. Accuracy improvement in a calibration test bench for accelerometers by a vision system

    Energy Technology Data Exchange (ETDEWEB)

    D’Emilia, Giulio, E-mail: giulio.demilia@univaq.it; Di Gasbarro, David, E-mail: david.digasbarro@graduate.univaq.it; Gaspari, Antonella, E-mail: antonella.gaspari@graduate.univaq.it; Natale, Emanuela, E-mail: emanuela.natale@univaq.it [University of L’Aquila, Department of Industrial and Information Engineering and Economics (DIIIE), via G. Gronchi, 18, 67100 L’Aquila (Italy)

    2016-06-28

    A procedure is described in this paper for the accuracy improvement of calibration of low-cost accelerometers in a prototype rotary test bench, driven by a brushless servo-motor and operating in a low frequency range of vibrations (0 to 5 Hz). Vibration measurements by a vision system based on a low frequency camera have been carried out, in order to reduce the uncertainty of the real acceleration evaluation at the installation point of the sensor to be calibrated. A preliminary test device has been realized and operated in order to evaluate the metrological performances of the vision system, showing a satisfactory behavior if the uncertainty measurement is taken into account. A combination of suitable settings of the control parameters of the motion control system and of the information gained by the vision system allowed to fit the information about the reference acceleration at the installation point to the needs of the procedure for static and dynamic calibration of three-axis accelerometers.

  17. Determination of the primary technical parameters of the test bench for controlling the temperature of rails and rail bars of continuous welded rail

    Directory of Open Access Journals (Sweden)

    Tertychnyi Vitalii

    2017-01-01

    Full Text Available One of the most important factors determining the reliability and safety of operation of the continuous welded rail track is the temperature of the rails. All conditions of laying, repair and maintenance of the track during the entire cycle of rails operation depend on it. The existing rail temperature monitoring method does not take into account a few significant factors and that leads to significant errors in determining the actual temperature of the rail bar. The authors propose a new rail temperature measurement method on a special test bench which maximally simulates possible environmental operating conditions for the rail bars, the profile of the roadway (embankment or cut, as well as the actual spatial latitude and meridian location of the rail slabs. At the bench, the studied rails are fastened with the help of rail braces on half ties, in the ballast bed, with sizes in accordance with the existing reference documents. At the first stage, the most common KB-65 intermediate fastener for the continuous welded rail in Ukraine will be used, while in subsequent stages KPP-5 fastening will be used.

  18. Microcalcification detectability using a bench-top prototype photon-counting breast CT based on a Si strip detector.

    Science.gov (United States)

    Cho, Hyo-Min; Ding, Huanjun; Barber, William C; Iwanczyk, Jan S; Molloi, Sabee

    2015-07-01

    To investigate the feasibility of detecting breast microcalcification (μCa) with a dedicated breast computed tomography (CT) system based on energy-resolved photon-counting silicon (Si) strip detectors. The proposed photon-counting breast CT system and a bench-top prototype photon-counting breast CT system were simulated using a simulation package written in matlab to determine the smallest detectable μCa. A 14 cm diameter cylindrical phantom made of breast tissue with 20% glandularity was used to simulate an average-sized breast. Five different size groups of calcium carbonate grains, from 100 to 180 μm in diameter, were simulated inside of the cylindrical phantom. The images were acquired with a mean glandular dose (MGD) in the range of 0.7-8 mGy. A total of 400 images was used to perform a reader study. Another simulation study was performed using a 1.6 cm diameter cylindrical phantom to validate the experimental results from a bench-top prototype breast CT system. In the experimental study, a bench-top prototype CT system was constructed using a tungsten anode x-ray source and a single line 256-pixels Si strip photon-counting detector with a pixel pitch of 100 μm. Calcium carbonate grains, with diameter in the range of 105-215 μm, were embedded in a cylindrical plastic resin phantom to simulate μCas. The physical phantoms were imaged at 65 kVp with an entrance exposure in the range of 0.6-8 mGy. A total of 500 images was used to perform another reader study. The images were displayed in random order to three blinded observers, who were asked to give a 4-point confidence rating on each image regarding the presence of μCa. The μCa detectability for each image was evaluated by using the average area under the receiver operating characteristic curve (AUC) across the readers. The simulation results using a 14 cm diameter breast phantom showed that the proposed photon-counting breast CT system can achieve high detection accuracy with an average AUC greater

  19. ACUTE EFFECTS OF MOVEMENT VELOCITY ON BLOOD LACTATE AND GROWTH HORMONE RESPONSES AFTER ECCENTRIC BENCH PRESS EXERCISE IN RESISTANCE-TRAINED MEN

    OpenAIRE

    Calixto, RD; Verlengia, R; Crisp, AH; Carvalho, TB; Crepaldi, MD; Pereira, AA; Yamada, AK; da Mota, GR; Lopes, CR

    2014-01-01

    This study aimed to compare the effects of different velocities of eccentric muscle actions on acute blood lactate and serum growth hormone (GH) concentrations following free weight bench press exercises performed by resistance-trained men. Sixteen healthy men were divided into two groups: slow eccentric velocity (SEV; n = 8) and fast eccentric velocity (FEV; n = 8). Both groups performed four sets of eight eccentric repetitions at an intensity of 70% of their one repetition maximum eccentric...

  20. Bench evaluation of 7 home-care ventilators.

    Science.gov (United States)

    Blakeman, Thomas C; Rodriquez, Dario; Hanseman, Dennis; Branson, Richard D

    2011-11-01

    Portable ventilators continue to decrease in size while increasing in performance. We bench-tested the triggering, battery duration, and tidal volume (V(T)) of 7 portable ventilators: LTV 1000, LTV 1200, Puritan Bennett 540, Trilogy, Vela, iVent 101, and HT50. We tested triggering with a modified dual-chamber test lung to simulate spontaneous breathing with weak, normal, and strong inspiratory effort. We measured battery duration by fully charging the battery and operating the ventilator with a V(T) of 500 mL, a respiratory rate of 20 breaths/min, and PEEP of 5 cm H(2)O until breath-delivery ceased. We tested V(T) accuracy with pediatric ventilation scenarios (V(T) 50 mL or 100 mL, respiratory rate 50 breaths/min, inspiratory time 0.3 s, and PEEP 5 cm H(2)O) and an adult ventilation scenario (V(T) 400 mL, respiratory rate 30 breaths/min, inspiratory time 0.5 s, and PEEP 5 cm H(2)O). We measured and analyzed airway pressure, volume, and flow signals. At the adult settings the measured V(T) range was 362-426 mL. On the pediatric settings the measured V(T) range was 51-182 mL at the set V(T) of 50 mL, and 90-141 mL at the set V(T) of 100 mL. The V(T) delivered by the Vela at both the 50 mL and 100 mL, and by the HT50 at 100 mL, did not meet the American Society for Testing and Materials standard for V(T) accuracy. Triggering response and battery duration ranged widely among the tested ventilators. There was wide variability in battery duration and triggering sensitivity. Five of the ventilators performed adequately in V(T) delivery across several settings. The combination of high respiratory rate and low V(T) presented problems for 2 of the ventilators.

  1. R.I.P. squad bench. European ambulances designed around the patient, not the vehicle.

    Science.gov (United States)

    Heightman, A J

    2013-07-01

    You can see and hear more about my journey throughout Germany and England in a special, archived, free Webcast on jems.com. And in future articles, videos and Web presentations, you'll see and learn about the different EMS delivery models I saw, the men and women whom I met and rode with on calls, and, most importantly, their impressive attitude about patient care, customer service and safety. Progressive American and Canadian ambulance manufacturers now agree with safety experts and forward-thinking ambulance operators that the squad bench is dead. These manufacturers now offer innovative seats that are much safer and functional than those coffin-like obstructions that gobbled up so much space in our rigs for the past three decades. Design your next ambulance around the needs and safety of your crews and their patients, and spec a patient compartment that is laid out logiclaly and efficient.

  2. Validity of a Commercial Linear Encoder to Estimate Bench Press 1 RM from the Force-Velocity Relationship

    Science.gov (United States)

    Bosquet, Laurent; Porta-Benache, Jeremy; Blais, Jérôme

    2010-01-01

    The aim of this study was to assess the validity and accuracy of a commercial linear encoder (Musclelab, Ergotest, Norway) to estimate Bench press 1 repetition maximum (1RM) from the force - velocity relationship. Twenty seven physical education students and teachers (5 women and 22 men) with a heterogeneous history of strength training participated in this study. They performed a 1 RM test and a force - velocity test using a Bench press lifting task in a random order. Mean 1 RM was 61.8 ± 15.3 kg (range: 34 to 100 kg), while 1 RM estimated by the Musclelab’s software from the force-velocity relationship was 56.4 ± 14.0 kg (range: 33 to 91 kg). Actual and estimated 1 RM were very highly correlated (r = 0.93, p<0.001) but largely different (Bias: 5.4 ± 5.7 kg, p < 0.001, ES = 1.37). The 95% limits of agreement were ±11.2 kg, which represented ±18% of actual 1 RM. It was concluded that 1 RM estimated from the force-velocity relationship was a good measure for monitoring training induced adaptations, but also that it was not accurate enough to prescribe training intensities. Additional studies are required to determine whether accuracy is affected by age, sex or initial level. Key points Some commercial devices allow to estimate 1 RM from the force-velocity relationship. These estimations are valid. However, their accuracy is not high enough to be of practical help for training intensity prescription. Day-to-day reliability of force and velocity measured by the linear encoder has been shown to be very high, but the specific reliability of 1 RM estimated from the force-velocity relationship has to be determined before concluding to the usefulness of this approach in the monitoring of training induced adaptations. PMID:24149641

  3. A Comparison of Aerobic Fitness Testing on a Swim Bench and Treadmill in a Recreational Surfing Cohort: A Pilot Study

    Directory of Open Access Journals (Sweden)

    Hamzeh Khundaqji

    2018-06-01

    Full Text Available The intermittent manner of surfing accentuates the importance of both the aerobic and anaerobic energy systems. Currently, the optimal method of assessing surfing-specific aerobic fitness is using a swim bench (SWB ergometer; however, their limited availability presents a barrier to surfers wanting to know their maximal aerobic power (VO2peak. As a result, the aims of this pilot study were to determine the VO2peak of recreational surfers using a new commercial SWB ergometer and to propose and examine the feasibility of a regression model to predict SWB ergometer VO2peak values. A total of nine recreational surfers were assessed where body measurements were conducted followed by maximal aerobic capacity testing (swim bench and treadmill to profile the cohort. Findings demonstrated that VO2peak values were significantly greater (p < 0.001 on the treadmill compared to the SWB ergometer (M = 66.01 ± 8.23 vs. 37.41 ± 8.73 mL/kg/min. Peak heart rate was also significantly greater on the treadmill compared to the SWB ergometer. Multiple regression analysis was used to produce a model which predicted SWB VO2peak values with an R2 value of 0.863 and an adjusted R2 value of 0.726. The physiological profiling of the recreational cohort coupled with a surfer’s predicted SWB VO2peak value will allow for identification of surfing-specific aerobic fitness levels and evidence-based training recommendations.

  4. Efficacy Of The Repetitions In Reserve-Based Rating Of Perceived Exertion For The Bench Press In Experienced And Novice Benchers.

    Science.gov (United States)

    Ormsbee, Michael J; Carzoli, Joseph P; Klemp, Alex; Allman, Brittany R; Zourdos, Michael C; Kim, Jeong-Su; Panton, Lynn B

    2017-03-13

    Autoregulation (AR) is the practice of adjusting training variables in response to athlete feedback. One component of AR postulated to enhance resistance training adaptations involves implementing a resistance training-specific rating of perceived exertion (RPE) scale measuring repetitions in reserve (RIR). The purpose of this study was to examine the efficacy of this method using the bench press exercise. Twenty-seven college-aged men were assigned to one of two groups based upon training age: experience benchers (EB) (n=14, training age: 4.7±2.0 yrs) and novice benchers (NB) (n=13, training age: 1.1±0.6 yrs). Subjects performed one-repetition maximum (1RM) followed by single-repetition sets with loads corresponding to 60, 75, and 90% of 1RM and an 8-repetition set at 70% 1RM. Subjects reported a corresponding RPE, based on RIR, for every set. Average velocity was recorded for each single-repetition set along with the first and last repetitions of the 8-repetition set at 70% 1RM. Average velocity at 100% of 1RM in EB was slower (0.14±0.04 m[BULLET OPERATOR]s) compared to NB (0.20±0.05 m[BULLET OPERATOR]s) (pvelocity or RPE at any other intensity. Both EB (r=0.85, pvelocity and RPE at all intensities. Our findings suggest that the RIR-based RPE scale may be an efficacious approach for AR of bench press training load and volume in college-aged men.

  5. Calculation of force and power during bench throws using a Smith machine: the importance of considering the effect of counterweights.

    Science.gov (United States)

    Kobayashi, Y; Narazaki, K; Akagi, R; Nakagaki, K; Kawamori, N; Ohta, K

    2013-09-01

    For achieving accurate and safe measurements of the force and power exerted on a load during resistance exercise, the Smith machine has been used instead of free weights. However, because some Smith machines possess counterweights, the equation for the calculation of force and power in this system should be different from the one used for free weights. The purpose of this investigation was to calculate force and power using an equation derived from a dynamic equation for a Smith machine with counterweights and to determine the differences in force and power calculated using 2 different equations. One equation was established ignoring the effect of the counterweights (Method 1). The other equation was derived from a dynamic equation for a barbell and counterweight system (Method 2). 9 female collegiate judo athletes performed bench throws using a Smith machine with a counterweight at 6 different loading conditions. Barbell displacement was recorded using a linear position transducer. The force and power were subsequently calculated by Methods 1 and 2. The results showed that the mean and peak power and force in Method 1 were significantly lower relative to those of Method 2 under all loading conditions. These results indicate that the mean and peak power and force during bench throwing using a Smith machine with counterweights would be underestimated when the calculations used to determine these parameters do not account for the effect of counterweights. © Georg Thieme Verlag KG Stuttgart · New York.

  6. A bench-top K X-ray fluorescence system for quantitative measurement of gold nanoparticles for biological sample diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Ricketts, K., E-mail: k.ricketts@ucl.ac.uk [Division of Surgery and Interventional Sciences, University College London, Royal Free Campus, Rowland Hill Street, London NW3 2PF (United Kingdom); Guazzoni, C.; Castoldi, A. [Dipartimento di Elettronica, Informazione e Bioingegneria Politecnico di Milano and INFN, Sezione di Milano P.za Leonardo da Vinci, 32-20133 Milano (Italy); Royle, G. [Department of Medical Physics and Bioengineering, University College London, Malet Place Engineering Building, Gower Street, London WC1E 6BT (United Kingdom)

    2016-04-21

    Gold nanoparticles can be targeted to biomarkers to give functional information on a range of tumour characteristics. X-ray fluorescence (XRF) techniques offer potential quantitative measurement of the distribution of such heavy metal nanoparticles. Biologists are developing 3D tissue engineered cellular models on the centimetre scale to optimise targeting techniques of nanoparticles to a range of tumour characteristics. Here we present a high energy bench-top K-X-ray fluorescence system designed for sensitivity to bulk measurement of gold nanoparticle concentration for intended use in such thick biological samples. Previous work has demonstrated use of a L-XRF system in measuring gold concentrations but being a low energy technique it is restricted to thin samples or superficial tumours. The presented system comprised a high purity germanium detector and filtered tungsten X-ray source, capable of quantitative measurement of gold nanoparticle concentration of thicker samples. The developed system achieved a measured detection limit of between 0.2 and 0.6 mgAu/ml, meeting specifications of biologists and being approximately one order of magnitude better than the detection limit of alternative K-XRF nanoparticle detection techniques. The scatter-corrected K-XRF signal of gold was linear with GNP concentrations down to the detection limit, thus demonstrating potential in GNP concentration quantification. The K-XRF system demonstrated between 5 and 9 times less sensitivity than a previous L-XRF bench-top system, due to a fundamental limitation of lower photoelectric interaction probabilities at higher K-edge energies. Importantly, the K-XRF technique is however less affected by overlying thickness, and so offers future potential in interrogating thick biological samples.

  7. Eating disorders: from bench to bedside and back.

    Science.gov (United States)

    Gaetani, Silvana; Romano, Adele; Provensi, Gustavo; Ricca, Valdo; Lutz, Thomas; Passani, Maria Beatrice

    2016-12-01

    The central nervous system and viscera constitute a functional ensemble, the gut-brain axis, that allows bidirectional information flow that contributes to the control of feeding behavior based not only on the homeostatic, but also on the hedonic aspects of food intake. The prevalence of eating disorders, such as anorexia nervosa, binge eating and obesity, poses an enormous clinical burden, and involves an ever-growing percentage of the population worldwide. Clinical and preclinical research is constantly adding new information to the field and orienting further studies with the aim of providing a foundation for developing more specific and effective treatment approaches to pathological conditions. A recent symposium at the XVI Congress of the Societá Italiana di Neuroscienze (SINS, 2015) 'Eating disorders: from bench to bedside and back' brought together basic scientists and clinicians with the objective of presenting novel perspectives in the neurobiology of eating disorders. Clinical studies presented by V. Ricca illustrated some genetic aspects of the psychopathology of anorexia nervosa. Preclinical studies addressed different issues ranging from the description of animal models that mimic human pathologies such as anorexia nervosa, diet-induced obesity, and binge eating disorders (T. Lutz), to novel interactions between peripheral signals and central circuits that govern food intake, mood and stress (A. Romano and G. Provensi). The gut-brain axis has received increasing attention in the recent years as preclinical studies are demonstrating that the brain and visceral organs such as the liver and guts, but also the microbiota are constantly engaged in processes of reciprocal communication, with unexpected physiological and pathological implications. Eating is controlled by a plethora of factors; genetic predisposition, early life adverse conditions, peripheral gastrointestinal hormones that act directly or indirectly on the central nervous system, all are

  8. Bench-scale studies with mercury contaminated SRS soil

    International Nuclear Information System (INIS)

    Cicero, C.A.

    1995-01-01

    Bench-scale studies with mercury contaminated soil were performed at the SRTC to determine the optimum waste loading obtainable in the glass product without sacrificing durability, leach resistance, and processability. Vitrifying this waste stream also required offgas treatment for the capture of the vaporized mercury. Four soil glasses with slight variations in composition were produced, which were capable of passing the Product Consistency Test (PCT) and the Toxicity Characteristic Leaching Procedure (TCLP). The optimum glass feed composition contained 60 weight percent soil and produced a soda-lime-silica glass when melted at 1,350 C. The glass additives used to produce this glass were 24 weight percent Na 2 CO 3 and 16 weight percent CaCO 3 . Volatilized mercury released during the vitrification process was released to the proposed mercury collection system. The proposed mercury collection system consisted of quartz and silica tubing with a Na 2 S wash bottle followed by a NaOH wash bottle. Once in the system, the volatile mercury would pass through the wash bottle containing Na 2 S, where it would be converted to Hg 2 S, which is a stable form of mercury. However, attempts to capture the volatilized mercury in a Na 2 S solution wash bottle were not as successful as anticipated. Maximum mercury captured was only about 3.24% of the mercury contained in the feed. Mercury capture efforts then shifted to condensing and capturing the volatilized mercury. These attempts were much more successful at capturing the volatile mercury, with a capture efficiency of 34.24% when dry ice was used to pack the condenser. This captured mercury was treated on a mercury specific resin after digestion of the volatilized mercury

  9. A bench study of intensive-care-unit ventilators: new versus old and turbine-based versus compressed gas-based ventilators

    Science.gov (United States)

    Thille, Arnaud W.; Lyazidi, Aissam; Richard, Jean-Christophe M.; Galia, Fabrice; Brochard, Laurent

    2009-01-01

    Objective To compare 13 commercially available, new-generation, intensive-care-unit (ICU) ventilators regarding trigger function, pressurization capacity during pressure-support ventilation (PSV), accuracy of pressure measurements and expiratory resistance. Design and Setting Bench study at a research laboratory in a university hospital. Material Four turbine-based ventilators and nine conventional servo-valve compressed-gas ventilators were tested using a two-compartment lung model. Results Three levels of effort were simulated. Each ventilator was evaluated at four PSV levels (5, 10, 15, and 20 cm H2O), with and without positive end-expiratory pressure (5 cm H2O, Trigger function was assessed as the time from effort onset to detectable pressurization. Pressurization capacity was evaluated using the airway pressure-time product computed as the net area under the pressure-time curve over the first 0.3 s after inspiratory effort onset. Expiratory resistance was evaluated by measuring trapped volume in controlled ventilation. Significant differences were found across the ventilators, with a range of triggering-delay from 42 ms to 88 ms for all conditions averaged (Pventilators at PSV5 and three at PSV10, suggesting an inability to unload patient’s effort. On average, turbine-based ventilators performed better than conventional ventilators, which showed no improvement compared to a 2000 bench comparison. Conclusion Technical performances of trigger function, pressurization capacity and expiratory resistance vary considerably across new-generation ICU ventilators. ICU ventilators seem to have reached a technical ceiling in recent years, and some ventilators still perform inadequately. PMID:19352622

  10. Bench-Scale Development of a Hot Carbonate Absorption Process with Crystallization-Enabled High-Pressure Stripping for Post-Combustion CO{sub 2} Capture

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Yongqi; DeVries, Nicholas; Ruhter, David; Manoranjan, Sahu; Ye, Qing; Ye, Xinhuai; Zhang, Shihan; Chen, Scott; Li, Zhiwei; O' Brien, Kevin

    2014-03-31

    A novel Hot Carbonate Absorption Process with Crystallization-Enabled High-Pressure Stripping (Hot-CAP) has been developed by the University of Illinois at Urbana-Champaign and Carbon Capture Scientific, LLC in this three-year, bench-scale project. The Hot-CAP features a concentrated carbonate solution (e.g., K{sub 2}CO{sub 3}) for CO{sub 2} absorption and a bicarbonate slurry (e.g., KHCO{sub 3}) for high-pressure CO{sub 2} stripping to overcome the energy use and other disadvantages associated with the benchmark monoethanolamine (MEA) process. The project was aimed at performing laboratory- and bench-scale experiments to prove its technical feasibility and generate process engineering and scale-up data, and conducting a techno-economic analysis (TEA) to demonstrate its energy use and cost competitiveness over MEA. To meet project goals and objectives, a combination of experimental, modeling, process simulation, and economic analysis studies were applied. Carefully designed and intensive experiments were conducted to measure thermodynamic and reaction engineering data relevant to four major unit operations in the Hot-CAP (i.e., CO{sub 2} absorption, CO{sub 2} stripping, bicarbonate crystallization, and sulfate reclamation). The rate promoters that could accelerate the CO{sub 2} absorption rate into the potassium carbonate/bicarbonate (PCB) solution to a level greater than that into the 5 M MEA solution were identified, and the superior performance of CO{sub 2} absorption into PCB was demonstrated in a bench-scale packed-bed column. Kinetic data on bicarbonate crystallization were developed and applied for crystallizer design and sizing. Parametric testing of high-pressure CO{sub 2} stripping with concentrated bicarbonate-dominant slurries at high temperatures ({>=}140{degrees}C) in a bench-scale stripping column demonstrated lower heat use than with MEA. The feasibility of a modified process for combining SO{sub 2} removal with CO{sub 2} capture was preliminarily

  11. From bench to bedside: successful translational nanomedicine: highlights of the Third Annual Meeting of the American Academy of Nanomedicine.

    Science.gov (United States)

    Wei, Chiming; Liu, Nanhai; Xu, Pingyi; Heller, Mike; Tomalia, Donald A; Haynie, Donald T; Chang, Esther H; Wang, Kuan; Lee, Yoon-Sik; Lyubchenko, Yuri L; Bawa, Raj; Tian, Ryan; Hanes, Justin; Pun, Suzie; Meiners, Jens-Christian; Guo, Peixuan

    2007-12-01

    The Third Annual Meeting of the American Academy of Nanomedicine (AANM) was held at the University of California San Diego, in San Diego, California during September 7-8, 2007. The meeting was focused on successful translational nanomedicine: from bench to bedside. There were four keynote lectures and eight scientific symposiums in this meeting. The researchers and investigators reported the results and process of current nanomedicine research and approaches to clinical applications. The meeting provided exciting information for nanomedicine clinical-related researches and strategy for further development of nanomedicine research which will be benefits to clinical practice.

  12. TimeBench: a data model and software library for visual analytics of time-oriented data.

    Science.gov (United States)

    Rind, Alexander; Lammarsch, Tim; Aigner, Wolfgang; Alsallakh, Bilal; Miksch, Silvia

    2013-12-01

    Time-oriented data play an essential role in many Visual Analytics scenarios such as extracting medical insights from collections of electronic health records or identifying emerging problems and vulnerabilities in network traffic. However, many software libraries for Visual Analytics treat time as a flat numerical data type and insufficiently tackle the complexity of the time domain such as calendar granularities and intervals. Therefore, developers of advanced Visual Analytics designs need to implement temporal foundations in their application code over and over again. We present TimeBench, a software library that provides foundational data structures and algorithms for time-oriented data in Visual Analytics. Its expressiveness and developer accessibility have been evaluated through application examples demonstrating a variety of challenges with time-oriented data and long-term developer studies conducted in the scope of research and student projects.

  13. Numerical modelling of orthogonal cutting: application to woodworking with a bench plane.

    Science.gov (United States)

    Nairn, John A

    2016-06-06

    A numerical model for orthogonal cutting using the material point method was applied to woodcutting using a bench plane. The cutting process was modelled by accounting for surface energy associated with wood fracture toughness for crack growth parallel to the grain. By using damping to deal with dynamic crack propagation and modelling all contact between wood and the plane, simulations could initiate chip formation and proceed into steady-state chip propagation including chip curling. Once steady-state conditions were achieved, the cutting forces became constant and could be determined as a function of various simulation variables. The modelling details included a cutting tool, the tool's rake and grinding angles, a chip breaker, a base plate and a mouth opening between the base plate and the tool. The wood was modelled as an anisotropic elastic-plastic material. The simulations were verified by comparison to an analytical model and then used to conduct virtual experiments on wood planing. The virtual experiments showed interactions between depth of cut, chip breaker location and mouth opening. Additional simulations investigated the role of tool grinding angle, tool sharpness and friction.

  14. Great expectations – Epigenetics and the meandering path from bench to bedside

    Directory of Open Access Journals (Sweden)

    Sophia J. Häfner

    2016-06-01

    Full Text Available Making quick promises of major biomedical breakthroughs based on exciting discoveries at the bench is tempting. But the meandering path from fundamental science to life-saving clinical applications can be fraught with many hurdles. Epigenetics, the study of potentially heritable changes of gene function without modification of the underlying DNA sequence, has dominated the biological research field during the last decade and encountered a large public success. Driven by the unfolding of molecular biology and recent technological progress, the term has evolved significantly and shifted from a conceptual framework to a mechanistic understanding. This shift was accompanied by much hype and raised high hopes that epigenetics might hold both the key to deciphering the molecular underpinning of complex, non-Mendelian diseases and offer novel therapeutic approaches for a large panel of pathologies. However, while exciting reports of biological phenomena involving DNA methylation and histone modifications fill up the scientific literature, the realistic clinical applications of epigenetic medicines remain somewhat blurry. Here, we discuss the state of the art and speculate how epigenetics might contribute to prognostic and therapy approaches in the future.

  15. Bench-Scale Evaluation of Hydrothermal Processing Technology for Conversion of Wastewater Solids to Fuels

    Energy Technology Data Exchange (ETDEWEB)

    Marrone, Philip A.; Elliott, Douglas C.; Billing, Justin M.; Hallen, Richard T.; Hart, Todd R.; Kadota, Paul; Moeller, Jeff C.; Randel, Margaaret A.; Schmidt, Andrew J.

    2018-04-01

    Hydrothermal Liquefaction (HTL) and Catalytic Hydrothermal Gasification (CHG) proof-of-concept bench-scale tests were performed to assess the potential of hydrothermal treatment for handling municipal wastewater sludge. HTL tests were conducted at 300-350°C and 20 MPa on three different feeds: primary sludge, secondary sludge, and digested solids. Corresponding CHG tests were conducted at 350°C and 20 MPa on the HTL aqueous phase output using a ruthenium based catalyst. Biocrude yields ranged from 25-37%. Biocrude composition and quality were comparable to biocrudes generated from algae feeds. Subsequent hydrotreating of biocrude resulted in a product with comparable physical and chemical properties to crude oil. CHG product gas methane yields on a carbon basis ranged from 47-64%. Siloxane concentrations in the CHG product gas were below engine limits. The HTL-CHG process resulted in a chemical oxygen demand (COD) reduction of > 99.9% and a reduction in residual solids for disposal of 94-99%.

  16. Bench-scale demonstration of treatment technologies for contaminated sediments in Sydney Tar Ponds

    International Nuclear Information System (INIS)

    Volchek, K.; Velicogna, D.; Punt, M.; Wong, B.; Weimer, L.; Tsangaris, A.; Brown, C.E.

    2003-01-01

    A series of bench-scale tests were conducted to determine the capabilities of selected commercially available technologies for treating contaminated sediments from the South Pond of Sydney Tar Ponds. This study was conducted under the umbrella of a technology demonstration program aimed at evaluating technologies to be used in the remediation of such sediments. The following approach was proposed by SAIC Canada for the treatment of the sediments: (1) solvent extraction for the removal of organic contaminants, (2) acid/chelant leaching for the removal of inorganic contaminants such as heavy metals, and (3) plasma hearth process for the destruction of toxic streams resulting from the first two processes. Solvent extraction followed by plasma treatment proved effective for removing and destroying organic contaminants. The removal of metals did not achieve the expected results through leaching. An approach was proposed for treating those sediments based on the results of the study. The approach differed depending on the level of organic content. An assessment of associated process costs for both a pilot-scale field demonstration and a full-scale treatment was provided. 11 tabs., 4 figs

  17. Potential for reducing global carbon emissions from electricity production-A bench marking analysis

    Energy Technology Data Exchange (ETDEWEB)

    Ang, B.W.; Zhou, P.; Tay, L.P. [National University of Singapore (Singapore). Department of Industrial and Systems Engineering

    2011-05-15

    We present five performance indicators for electricity generation for 129 countries using the 2005 data. These indicators, measured at the national level, are the aggregate CO{sub 2} intensity of electricity production, the efficiencies of coal, oil and gas generation and the share of electricity produced from non-fossil fuels. We conduct a study on the potential for reducing global energy-related CO{sub 2} emissions from electricity production through simple bench marking. This is performed based on the last four performance indicators and the construction of a cumulative curve for each of these indicators. It is found that global CO{sub 2} emissions from electricity production would be reduced by 19% if all these indicators are benchmarked at the 50th percentile. Not surprisingly, the emission reduction potential measured in absolute terms is the highest for large countries such as China, India, Russia and the United States. When the potential is expressed as a percentage of a country's own emissions, few of these countries appear in the top-five list. 14 refs., 8 figs., 4 tabs.

  18. Continuous bench-scale slurry catalyst testing direct coal liquefaction rawhide sub-bituminous coal

    Energy Technology Data Exchange (ETDEWEB)

    Bauman, R.F.; Coless, L.A.; Davis, S.M. [and others

    1995-12-31

    In 1992, the Department of Energy (DOE) sponsored research to demonstrate a dispersed catalyst system using a combination of molybdenum and iron precursors for direct coal liquefaction. This dispersed catalyst system was successfully demonstrated using Black Thunder sub-bituminous coal at Wilsonville, Alabama by Southern Electric International, Inc. The DOE sponsored research continues at Exxon Research and Development Laboratories (ERDL). A six month continuous bench-scale program using ERDL`s Recycle Coal Liquefaction Unit (RCLU) is planned, three months in 1994 and three months in 1995. The initial conditions in RCLU reflect experience gained from the Wilsonville facility in their Test Run 263. Rawhide sub-bituminous coal which is similar to the Black Thunder coal tested at Wilsonville was used as the feed coal. A slate of five dispersed catalysts for direct coal liquefaction of Rawhide sub-bituminous coal has been tested. Throughout the experiments, the molybdenum addition rate was held constant at 100 wppm while the iron oxide addition rate was varied from 0.25 to 1.0 weight percent (dry coal basis). This report covers the 1994 operations and accomplishments.

  19. Impact of relative position vehicle-wind blower in a roller test bench under climatic chamber

    International Nuclear Information System (INIS)

    Fernández-Yáñez, P.; Armas, O.; Martínez-Martínez, S.

    2016-01-01

    Highlights: • Air simulation model was developed for a vehicle test bench under climatic chamber. • Good accuracy between experimental data and simulated values were obtained. • Wind blower-vehicle relative position alters external cooling of after-treatment devices. • Vehicle emission certification can be affected by wind blower-vehicle relative position. - Abstract: In terms of energy efficiency and exhaust emissions control, an appropriate design of cooling systems of climatic chambers destined to vehicle certification and/or perform scientific research is becoming increasingly important. European vehicle emissions certification (New European Driving Cycle, NEDC) establishes the position of the wind-simulation blower at 200 mm above floor level. This height is fixed and kept constant independently of the vehicle tested. The position of the blower with respect to the vehicle can modify the external forced convection under the car, where after-treatment devices are located. Consequently, the performance of such devices could be modified and emission results during the certification cycle could be non-representative of real-world driving conditions. The aim of this work is to study the influence of different wind blower-vehicle relative heights on the air velocity and temperature profiles under the car by means of a simple computational fluid dynamics (CFD) approach. A steady state three-dimensional CFD model was developed and applied to the estimation of the air velocity and temperature profiles inside of a climatic chamber equipped with a vehicle roller (chassis dyno) test bench. The simulations reproduce one steady-state condition from NEDC, specifically the EU17 mode (120 km/h, maximum velocity during the cycle). The cool air propelling temperature was 20 °C (minimum temperature in the NEDC range). Simulations were performed employing the Reynolds-Averaged Navier-Stokes (RANS) approach with the realizable k-ε model to provide closure. Air velocity and

  20. Submicronic Particle Measurement Instrumentation Test Bench Data Acquisition and Control System; Sistema de Toma de Datos y Control de un Banco de Calibracion de Instrumentacion para Medida de Particulas Submicrometricas

    Energy Technology Data Exchange (ETDEWEB)

    Alberdi, J; Barcala, J M; Gomez, F J; Molinero, A; Navarrete, J J [Ciemat. Madrid (Spain)

    1999-05-01

    This document describes the SAD-100 system characteristics. The unit makes the instrumentation test bench data acquisition and control, SAD-100 was designed and developed by Electronic and Automation Area (CIEMAT) and Aerosol Technology in Energy Generation Project (CIEMAT). (Author) 2 refs.

  1. A comparison of large-scale electron beam and bench-scale 60Co irradiations of simulated aqueous waste streams

    Science.gov (United States)

    Kurucz, Charles N.; Waite, Thomas D.; Otaño, Suzana E.; Cooper, William J.; Nickelsen, Michael G.

    2002-11-01

    The effectiveness of using high energy electron beam irradiation for the removal of toxic organic chemicals from water and wastewater has been demonstrated by commercial-scale experiments conducted at the Electron Beam Research Facility (EBRF) located in Miami, Florida and elsewhere. The EBRF treats various waste and water streams up to 450 l min -1 (120 gal min -1) with doses up to 8 kilogray (kGy). Many experiments have been conducted by injecting toxic organic compounds into various plant feed streams and measuring the concentrations of compound(s) before and after exposure to the electron beam at various doses. Extensive experimentation has also been performed by dissolving selected chemicals in 22,700 l (6000 gal) tank trucks of potable water to simulate contaminated groundwater, and pumping the resulting solutions through the electron beam. These large-scale experiments, although necessary to demonstrate the commercial viability of the process, require a great deal of time and effort. This paper compares the results of large-scale electron beam irradiations to those obtained from bench-scale irradiations using gamma rays generated by a 60Co source. Dose constants from exponential contaminant removal models are found to depend on the source of radiation and initial contaminant concentration. Possible reasons for observed differences such as a dose rate effect are discussed. Models for estimating electron beam dose constants from bench-scale gamma experiments are presented. Data used to compare the removal of organic compounds using gamma irradiation and electron beam irradiation are taken from the literature and a series of experiments designed to examine the effects of pH, the presence of turbidity, and initial concentration on the removal of various organic compounds (benzene, toluene, phenol, PCE, TCE and chloroform) from simulated groundwater.

  2. A comparison of large-scale electron beam and bench-scale 60Co irradiations of simulated aqueous waste streams

    International Nuclear Information System (INIS)

    Kurucz, Charles N.; Waite, Thomas D.; Otano, Suzana E.; Cooper, William J.; Nickelsen, Michael G.

    2002-01-01

    The effectiveness of using high energy electron beam irradiation for the removal of toxic organic chemicals from water and wastewater has been demonstrated by commercial-scale experiments conducted at the Electron Beam Research Facility (EBRF) located in Miami, Florida and elsewhere. The EBRF treats various waste and water streams up to 450 l min -1 (120 gal min -1 ) with doses up to 8 kilogray (kGy). Many experiments have been conducted by injecting toxic organic compounds into various plant feed streams and measuring the concentrations of compound(s) before and after exposure to the electron beam at various doses. Extensive experimentation has also been performed by dissolving selected chemicals in 22,700 l (6000 gal) tank trucks of potable water to simulate contaminated groundwater, and pumping the resulting solutions through the electron beam. These large-scale experiments, although necessary to demonstrate the commercial viability of the process, require a great deal of time and effort. This paper compares the results of large-scale electron beam irradiations to those obtained from bench-scale irradiations using gamma rays generated by a 60 Co source. Dose constants from exponential contaminant removal models are found to depend on the source of radiation and initial contaminant concentration. Possible reasons for observed differences such as a dose rate effect are discussed. Models for estimating electron beam dose constants from bench-scale gamma experiments are presented. Data used to compare the removal of organic compounds using gamma irradiation and electron beam irradiation are taken from the literature and a series of experiments designed to examine the effects of pH, the presence of turbidity, and initial concentration on the removal of various organic compounds (benzene, toluene, phenol, PCE, TCE and chloroform) from simulated groundwater

  3. Bench-test comparison of 26 emergency and transport ventilators.

    Science.gov (United States)

    L'Her, Erwan; Roy, Annie; Marjanovic, Nicolas

    2014-10-15

    Numerous emergency and transport ventilators are commercialized and new generations arise constantly. The aim of this study was to evaluate a large panel of ventilators to allow clinicians to choose a device, taking into account their specificities of use. This experimental bench-test took into account general characteristics and technical performances. Performances were assessed under different levels of FIO2 (100%, 50% or Air-Mix), respiratory mechanics (compliance 30,70,120 mL/cmH2O; resistance 5,10,20 cmH2O/mL/s), and levels of leaks (3.5 to 12.5 L/min), using a test lung. In total 26 emergency and transport ventilators were analyzed and classified into four categories (ICU-like, n = 5; Sophisticated, n = 10; Simple, n = 9; Mass-casualty and military, n = 2). Oxygen consumption (7.1 to 15.8 L/min at FIO2 100%) and the Air-Mix mode (FIO2 45 to 86%) differed from one device to the other. Triggering performance was heterogeneous, but several sophisticated ventilators depicted triggering capabilities as efficient as ICU-like ventilators. Pressurization was not adequate for all devices. At baseline, all the ventilators were able to synchronize, but with variations among respiratory conditions. Leak compensation in most ICU-like and 4/10 sophisticated devices was able to correct at least partially for system leaks, but with variations among ventilators. Major differences were observed between devices and categories, either in terms of general characteristics or technical reliability, across the spectrum of operation. Huge variability of tidal volume delivery with some devices in response to modifications in respiratory mechanics and FIO2 should make clinicians question their use in the clinical setting.

  4. Combined effects of leaks, respiratory system properties and upper airway patency on the performance of home ventilators: a bench study.

    Science.gov (United States)

    Zhu, Kaixian; Rabec, Claudio; Gonzalez-Bermejo, Jésus; Hardy, Sébastien; Aouf, Sami; Escourrou, Pierre; Roisman, Gabriel

    2017-11-21

    Combined effects of leaks, mechanical property of respiratory system and upper airway (UA) patency on patient-ventilator synchrony (PVA) and the level of clinically "tolerable" leaks are not well established in home ventilators. We comparatively assessed on a bench model, the highest leak level tolerated without inducing significant asynchrony ("critical leak") in three home ventilators (Astral 150, Trilogy 100 and Vivo 60; noted as A150, T100 and V60 respectively) subjected to three simulated diseased respiratory conditions: chronic obstructive pulmonary disease (COPD), obesity hypoventilation (OHS) and neuromuscular disorders (NMD), with both open and closed UA. Also, total leak values in the device reports were compared to the bench-measured values. With open UA, all ventilators were able to avoid asynchrony up to a 30 L/min leak and even to 55 L/min in some cases. UA closure and respiratory diseases especially OHS influenced PVA. With closed UA, the critical leak of A150 and T100 remained higher than 55 L/min in COPD and OHS, while for V60 decreased to 41 and 33 L/min respectively. In NMD with closed UA, only T100 reached a high critical leak of 69 L/min. Besides, inspiratory trigger sensitivity change was often necessary to avoid PVA. Home ventilators were able to avoid PVA in high-level leak conditions. However, asynchrony appeared in cases of abnormal mechanical properties of respiratory system or closed UA. In case of closed UA, the EPAP should be adjusted prior to the inspiratory trigger. Not applicable.

  5. Differences in the Load-Velocity Profile Between 4 Bench-Press Variants.

    Science.gov (United States)

    García-Ramos, Amador; Pestaña-Melero, Francisco Luis; Pérez-Castilla, Alejandro; Rojas, Francisco Javier; Haff, Guy Gregory

    2018-03-01

    To compare the load-velocity relationship between 4 variants of the bench-press (BP) exercise. The full load-velocity relationship of 30 men was evaluated by means of an incremental loading test starting at 17 kg and progressing to the individual 1-repetition maximum (1RM) in 4 BP variants: concentric-only BP, concentric-only BP throw (BPT), eccentric-concentric BP, and eccentric-concentric BPT. A strong and fairly linear relationship between mean velocity (MV) and %1RM was observed for the 4 BP variants (r 2  > .96 for pooled data and r 2  > .98 for individual data). The MV associated with each %1RM was significantly higher in the eccentric-concentric technique than in the concentric-only technique. The only significant difference between the BP and BPT variants was the higher MV with the light to moderate loads (20-70%1RM) in the BPT using the concentric-only technique. MV was significantly and positively correlated between the 4 BP variants (r = .44-.76), which suggests that the subjects with higher velocities for each %1RM in 1 BP variant also tend to have higher velocities for each %1RM in the 3 other BP variants. These results highlight the need for obtaining specific equations for each BP variant and the existence of individual load-velocity profiles.

  6. Studies on the hydroprocessing of deashed oil. 10. ; Comparison of the reaction performance between pilot plant and BSU. Deashed oil no suisoka bunkai hanno ni kansuru kenkyu. 10. ; Pilot to bench hanno sochi no hanno tokusei no hikaku

    Energy Technology Data Exchange (ETDEWEB)

    Hijiriyama, M.; Kaneko, T. (Mitsubishi Kasei Co., Tokyo (Japan)); Kageyama, Y. (Nippon Brown Coal Liquefaction Co. Ltd., Tokyo (Japan))

    1990-11-29

    The secondary hydroprocessing process in the two-stage hydrogenating liquefaction equipment under development at Nippon Brown Coal Liquefaction Company uses a fixed bed system. This paper describes operation of a bench reaction equipment using catalyst used in the pilot plant to compare it with fresh catalyst, and compare characteristics of the bench scale equipment with those of the pilot reactor. The catalyst is Ca-Ni-No/Al2O. The reaction was carried out in a gas-liquid downward parallel-flow fixed-bed reactor using deashed oil (DAO) with the same material as that used in the pilot plant and the same equilibrium solvent. The experiment result indicates that the used catalyst had its activity fallen below the fresh catalyst, but its temperature dependence was identical, and the selectivity on products of both catalysts was also identical. The result of reactions in the bench scale equipment clarified that the relationship between the DAO conversion rate and denitrogenation activity and the relationship between fa and H/C in the products are in good agreement, and that there is no difference in reaction selectivity. 5 refs., 6 figs., 1 tab.

  7. Therapeutics discovery: From bench to first in-human trials.

    Science.gov (United States)

    Al-Hujaily, Ensaf M; Khatlani, Tanvir; Alehaideb, Zeyad; Ali, Rizwan; Almuzaini, Bader; Alrfaei, Bahauddeen M; Iqbal, Jahangir; Islam, Imadul; Malik, Shuja; Marwani, Bader A; Massadeh, Salam; Nehdi, Atef; Alsomaie, Barrak; Debasi, Bader; Bushnak, Ibraheem; Noibi, Saeed; Hussain, Syed; Wajid, Wahid Abdul; Armand, Jean-Pierre; Gul, Sheraz; Oyarzabal, Julen; Rais, Rana; Bountra, Chas; Alaskar, Ahmed; Knawy, Bander Al; Boudjelal, Mohamed

    2018-03-01

    The 'Therapeutics discovery: From bench to first in-human trials' conference, held at the King Abdullah International Medical Research Center (KAIMRC), Ministry of National Guard Health Affairs (MNGHA), Kingdom of Saudi Arabia (KSA) from October 10-12, 2017, provided a unique opportunity for experts worldwide to discuss advances in drug discovery and development, focusing on phase I clinical trials. It was the first event of its kind to be hosted at the new research center, which was constructed to boost drug discovery and development in the KSA in collaboration with institutions, such as the Academic Drug Discovery Consortium in the United States of America (USA), Structural Genomics Consortium of the University of Oxford in the United Kingdom (UK), and Institute of Materia Medica of the Chinese Academy of Medical Sciences in China. The program was divided into two parts. A pre-symposium day took place on October 10, during which courses were conducted on clinical trials, preclinical drug discovery, molecular biology and nanofiber research. The attendees had the opportunity for one-to-one meetings with international experts to exchange information and foster collaborations. In the second part of the conference, which took place on October 11 and 12, the clinical trials pipeline, design and recruitment of volunteers, and economic impact of clinical trials were discussed. The Saudi Food and Drug Administration presented the regulations governing clinical trials in the KSA. The process of preclinical drug discovery from small molecules, cellular and immunologic therapies, and approaches to identifying new targets were also presented. The recommendation of the conference was that researchers in the KSA must invest more fund, talents and infrastructure to lead the region in phase I clinical trials and preclinical drug discovery. Diseases affecting the local population, such as Middle East Respiratory Syndrome and resistant bacterial infections, represent the optimal

  8. Continuous thermal degradation of pyrolytic oil in a bench scale CSTR reaction system

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyong Hwan; Nam, Ki Yun [Climate Change Technology Research Division, Korea Institute of Energy Research, 102 Gajeong-ro, Yuseong-gu, Daejeon 305-343 (Korea)

    2010-05-15

    Continuous thermal degradation of two pyrolytic oils with low (LPO) and high boiling point distribution (HPO) was conducted in a constant stirrer tank reactor (CSTR) with bench scale. Raw pyrolytic oil as a reactant was obtained from the commercial rotary kiln pyrolysis plant for municipal plastic waste. The degradation experiment was conducted by temperature programming with 10 C/min of heating rate up to 450 C and then maintained with long lapse time at 450 C. Liquid product was sampled at initial reaction time with different degradation temperatures up to 450 C and then constant interval lapse time at 450 C. The product characteristics over two pyrolytic oils were compared by using a continuous reaction system. As a reactant, heavy pyrolytic oil (HPO) showed higher boiling point distribution than that of diesel and also light pyrolytic oil (LPO) was mainly consisting of a mixture of gasoline and kerosene range components. In the continuous reaction, LPO showed higher yield of liquid product and lower residue than those of HPO. The characteristics of liquid products were influenced by the type of raw pyrolytic oil. Also, the result obtained under degradation temperature programming was described. (author)

  9. Destruction of chemical agent simulants in a supercritical water oxidation bench-scale reactor

    Energy Technology Data Exchange (ETDEWEB)

    Veriansyah, Bambang [Supercritical Fluid Research Laboratory, Clean Technology Research Center, Korea Institute of Science and Technology (KIST), 39-1 Hawolgok-dong, Seongbuk-gu, Seoul 136-791 (Korea, Republic of) and Department of Green Process and System Engineering, University of Science and Technology, 39-1 Hawolgok-dong, Seongbuk-gu, Seoul 136-791 (Korea, Republic of)]. E-mail: vaveri@kist.re.kr; Kim, Jae-Duck [Supercritical Fluid Research Laboratory, Clean Technology Research Center, Korea Institute of Science and Technology (KIST), 39-1 Hawolgok-dong, Seongbuk-gu, Seoul 136-791 (Korea, Republic of) and Department of Green Process and System Engineering, University of Science and Technology, 39-1 Hawolgok-dong, Seongbuk-gu, Seoul 136-791 (Korea, Republic of)]. E-mail: jdkim@kist.re.kr; Lee, Jong-Chol [Agency for Defense Development (ADD), P.O. Box 35-1, Yuseong-gu, Daejeon (Korea, Republic of)]. E-mail: jcleeadd@hanafos.com

    2007-08-17

    A new design of supercritical water oxidation (SCWO) bench-scale reactor has been developed to handle high-risk wastes resulting from munitions demilitarization. The reactor consists of a concentric vertical double wall in which SCWO reaction takes place inside an inner tube (titanium grade 2, non-porous) whereas pressure resistance is ensured by a Hastelloy C-276 external vessel. The performances of this reactor were investigated with two different kinds of chemical warfare agent simulants: OPA (a mixture of isopropyl amine and isopropyl alcohol) as the binary precursor for nerve agent of sarin and thiodiglycol [TDG (HOC{sub 2}H{sub 4}){sub 2}S] as the model organic sulfur heteroatom. High destruction rates based on total organic carbon (TOC) were achieved (>99.99%) without production of chars or undesired gases such as carbon monoxide and methane. The carbon-containing product was carbon dioxide whereas the nitrogen-containing products were nitrogen and nitrous oxide. Sulfur was totally recovered in the aqueous effluent as sulfuric acid. No corrosion was noticed in the reactor after a cumulative operation time of more than 250 h. The titanium tube shielded successfully the pressure vessel from corrosion.

  10. From bench to bedside and to health policies (and back: ethics in translational research

    Directory of Open Access Journals (Sweden)

    Carlo Petrini

    2014-03-01

    Full Text Available INTRODUCTION: The medical aim of translational research is to smooth the transition of discoveries made through basic research from the laboratory bench to their diagnostic or therapeutic applications for patients. These applications may be extended to current clinical practice and to health policies. AIM: The converse is also important: health policies should provide a point of departure when identifying research priorities. Translational research poses the same ethical problems as trials with human subjects - albeit in different ways. One of the more significant problems is the risk for participants in trials: it is thus necessary to ensure that the risks to which these subjects are exposed are not out of proportion to the expected benefits. DISCUSSION: Translational research does not require new ethical principles, but existing biomedical principles need to be adjusted to the specific context. The well-being of participants should always be the primary objective; these persons should never be considered as means for the advancement of knowledge or for the improvement of applications.

  11. The American Geriatrics Society/National Institute on Aging Bedside-to-Bench Conference: Research Agenda on Delirium in Older Adults

    Science.gov (United States)

    Mikhailovich, Anna

    2015-01-01

    The American Geriatrics Society, with support from the National Institute on Aging and the John A. Hartford Foundation, held its seventh Bedside-to-Bench research conference, entitled “Delirium in Older Adults: Finding Order in the Disorder” on February 9–11, 2014, to provide participants with opportunities to learn about cutting-edge research developments, draft recommendations for future research involving translational efforts, and opportunities to network with colleagues and leaders in the field. This meeting was the first of three conferences that will address delirium, sleep disorders, and voiding difficulties and urinary incontinence, emphasizing, whenever possible, the relationships and potentially shared clinical and pathophysiological features between these common geriatric syndromes. PMID:25834932

  12. Bench-Scale Synthetic Optimization of 1,2-bis(2-aminophenylthio)ethane (APO-Link) Used in the Production of APO-BMI Resin

    Energy Technology Data Exchange (ETDEWEB)

    Hilary Wheeler; Crystal Densmore

    2007-07-31

    The diamine reagent 1,2-bis(2-aminophenylthio)ethane is no longer commercially available but still required for the synthesis of the bismaleimide resin, APO-BMI, used in syntactic foams. In this work, we examined the hydrolysis of benzothiazole followed the by reaction with dichloroethane or dibromoethane. We also studied the deprotonation of 2-aminothiophenol followed by the reaction with dibromoethane. We optimized the latter for scale-up by scrutinizing all aspects of the reaction conditions, work-up and recrystallization. On bench-scale, our optimized procedure consistently produced a 75-80% overall yield of finely divided, high purity product (>95%).

  13. In-situ calibration: migrating control system IP module calibration from the bench to the storage ring

    International Nuclear Information System (INIS)

    Weber, Jonah M.; Chin, Michael

    2002-01-01

    The Control System for the Advanced Light Source (ALS) at Lawrence Berkeley National Lab (LBNL) uses in-house designed IndustryPack(registered trademark) (IP) modules contained in compact PCI (cPCI) crates with 16-bit analog I/O to control instrumentation. To make the IP modules interchangeable, each module is calibrated for gain and offset compensation. We initially developed a method of verifying and calibrating the IP modules in a lab bench test environment using a PC with LabVIEW. The subsequent discovery that the ADCs have significant drift characteristics over periods of days of installed operation prompted development of an ''in-situ'' calibration process--one in which the IP modules can be calibrated without removing them from the cPCI crates in the storage ring. This paper discusses the original LabVIEW PC calibration and the migration to the proposed in-situ EPICS control system calibration

  14. Safety analysis of the CSTR-1 bench-scale coal liquefaction unit

    Energy Technology Data Exchange (ETDEWEB)

    Hulburt, D.A.

    1981-05-01

    The objective of the program reported herein was to provide a Safety Analysis of the CSTR-1 bench scale unit located in Building 167 at the Pittsburgh Energy Technology Center. It was apparent that considerable effort was expended in the design and construction of the unit, and in the development of operating procedures, with regard to safety. Exhaust ventilation, H/sub 2/ and H/sub 2/S monitoring, overpressure protection, overtemperature protection, and interlock systems have been provided. Present settings on the pressure and temperature safety systems are too high, however, to insure prevention of vessel deformation or damage in all cases. While the occurrence of catastrophic rupture of a system pressure vessel (e.g., reactor, high pressure separators) is unlikely, the potential consequences to personnel are severe. Feasibility of providing shielding for these components should be considered. A more probable mode of vessel failure in the event of overpressure or overtemperature and failure of the safety system is yielding of the closure bolts followed by high pressure flow across the mating surfaces. As a minimum, shielding should be designed to restrict travel of resultant spray. The requirements for personal protective equipment are presently stated in rather broad and general terms in the operating procedures. Safe practices and procedures would be more assured if specific requirements were stated and included for each operational step. Recommendations were developed for all hazards triggered by the guidelines.

  15. Bench-Scale Silicone Process for Low-Cost CO{sub 2} Capture

    Energy Technology Data Exchange (ETDEWEB)

    Fresia, Megan; Vogt, Kirk

    2013-12-31

    GE Global Research is developing technology to remove carbon dioxide (CO{sub 2}) from the flue gas of coal-fired power plants. A mixture of 3-aminopropyl end-capped polydimethylsiloxane (GAP-1m) and triethylene glycol (TEG) is the preferred CO{sub 2} capture solvent. GE Global Research was contracted by the Department of Energy to test a bench-scale continuous CO{sub 2} absorption/desorption system using a GAP-1m/TEG mixture as the solvent. SiVance LLC was sub-contracted to provide the GAP-1m material and conduct an Environmental, Health, and Safety (EH&S) assessment for a 550 MW coal-fired power plant. Five components of the solvent, CAS#2469-55-8 (GAP-0), CAS#106214-84-0 (GAP-1-4), TEG, and methanol and xylene (minor contaminants from the aminosilicone) are included in this assessment. One by-product, GAP-1m/SOX salt, and dodecylbenzenesulfonic acid (DDBSA) were also identified for analysis. All of the solvent components and DDBSA are listed on the EPA’s TSCA Inventory allowing companies to manufacture and use the chemicals commercially. The toxicological effects of each component were defined, and control mechanisms necessary to comply with U.S. EH&S regulations are summarized. An engineering and control system, including environmental abatement, was described for minimizing exposure and release of the chemical components. Proper handling and storage recommendations are made for each chemical to minimize risk to workers and the surrounding community.

  16. Muscle power output properties using the stretch-shortening cycle of the upper limb and their relationships with a one-repetition maximum bench press.

    Science.gov (United States)

    Miyaguchi, Kazuyoshi; Demura, Shinichi

    2006-05-01

    The purpose of this study was to examine the output properties of muscle power by the dominant upper limb using SSC, and the relationships between the power output by SSC and a one-repetition maximum bench press (1 RM BP) used as a strength indicator of the upper body. Sixteen male athletes (21.4+/-0.9 yr) participated in this study. They pulled a load of 40% of maximum voluntary contraction (MVC) at a stretch by elbow flexion of the dominant upper limb in the following three preliminary conditions: static relaxed muscle state (SR condition), isometric muscle contraction state (ISO condition), and using SSC (SSC condition). The velocity with a wire load via a pulley during elbow flexion was measured accurately using a power instrument with a rotary encoder, and the muscle power curve was drawn from the product of the velocity and load. Significant differences were found among all evaluation parameters of muscle power exerted from the above three conditions and the parameters regarding early power output during concentric contraction were larger in the SSC condition than the SR and ISO conditions. The parameters on initial muscle contraction velocity when only using SSC significantly correlated with 1 RM BP (r=0.60-0.62). The use of SSC before powerful elbow flexion may contribute largely to early explosive power output during concentric contraction. Bench press capacity relates to a development of the above early power output when using SSC.

  17. 试论机修钳工与机械修理一体化%On the Integration of Machine Repairing Bench Worker and Machine Repairing

    Institute of Scientific and Technical Information of China (English)

    吴壮

    2015-01-01

    With the continuous development and progress of machine repairing in China, the demand of society for high level mechanical machine repairing bench workers has increased year by year. The machine tool repairing needs a lot of theory as the support foundation, and it also needs the sufficient curriculum practice to master the technology. All of these need the machine repairing bench workers fully combine the theory and practice in the personnel training activities. The personnel training method of combining machine repairing bench workers and machine repairing can effectively promote the theoretical study of the workers further implement the reasonable grasp of practical skills. This method can help them utilize the theory of knowledge to the specific practice, and also help them further understanding and master the theoretical knowledge in actual practice.%随着我国机修事业的不断发展与进步,使得社会对于高素质水平机修钳工的需求也逐年增多。机床的修理工作不仅需要借助大量的理论来作为基础支撑,同时也需要进行充分的课程实践来实现技术的有效掌握,这就要求其在钳工的人才培养活动中,必须实现理论与实践的充分结合。机修钳工与机械修理一体化的人才培养方法,能够有效促使钳工在理论学习的同时,也进一步的实现实践技能的合理掌握,不仅能够帮助其将所学的理论知识充分的运用到具体的实践活动中,也能进一步帮助其在实际的实践活动中来对理论知识进行更加深入的理解与掌握。

  18. Multifaceted bench comparative evaluation of latest intensive care unit ventilators.

    Science.gov (United States)

    Garnier, M; Quesnel, C; Fulgencio, J-P; Degrain, M; Carteaux, G; Bonnet, F; Similowski, T; Demoule, A

    2015-07-01

    Independent bench studies using specific ventilation scenarios allow testing of the performance of ventilators in conditions similar to clinical settings. The aims of this study were to determine the accuracy of the latest generation ventilators to deliver chosen parameters in various typical conditions and to provide clinicians with a comprehensive report on their performance. Thirteen modern intensive care unit ventilators were evaluated on the ASL5000 test lung with and without leakage for: (i) accuracy to deliver exact tidal volume (VT) and PEEP in assist-control ventilation (ACV); (ii) performance of trigger and pressurization in pressure support ventilation (PSV); and (iii) quality of non-invasive ventilation algorithms. In ACV, only six ventilators delivered an accurate VT and nine an accurate PEEP. Eleven devices failed to compensate VT and four the PEEP in leakage conditions. Inspiratory delays differed significantly among ventilators in invasive PSV (range 75-149 ms, P=0.03) and non-invasive PSV (range 78-165 ms, Pventilation algorithms efficiently prevented the decrease in pressurization capacities and PEEP levels induced by leaks in, respectively, 10 and 12 out of the 13 ventilators. We observed real heterogeneity of performance amongst the latest generation of intensive care unit ventilators. Although non-invasive ventilation algorithms appear to maintain adequate pressurization efficiently in the case of leakage, basic functions, such as delivered VT in ACV and pressurization in PSV, are often less reliable than the values displayed by the device suggest. © The Author 2015. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. Geodetic Control Points, Benchmarks; Vertical elevation bench marks for monumented geodetic survey control points for which mean sea level elevations have been determined., Published in 1995, 1:24000 (1in=2000ft) scale, Rhode Island and Providence Plantations.

    Data.gov (United States)

    NSGIC State | GIS Inventory — Geodetic Control Points dataset current as of 1995. Benchmarks; Vertical elevation bench marks for monumented geodetic survey control points for which mean sea level...

  20. The use of bench- and field-scale data for design of an in situ carbon tetrachloride bioremediation system

    International Nuclear Information System (INIS)

    Peyton, B.M.; Truex, M.J.; Skeen, R.S.

    1995-04-01

    A suite of simulation models were developed as a design tool in support of an in situ bioremediation demonstration at the Hanford site in Washington state. The design tool, calibrated with field - and bench-scale data, was used to answer four field-scale system design questions: (1) What are the important reaction processes and kinetics? (2) How will biomass distribute in the aquifer in response to injected substrate? (3) What well configuration best ensures proper nutrient transport and process control? (4) What operating and monitoring strategy should be used to confirm effective remediation? This paper does not describe the design tool itself, but describes how the design tool was used to optimize field site design parameters such as well spacing, hydraulic control, contaminant destruction, and nutrient injection strategies

  1. The Effects of Ballistic and Non-Ballistic Bench Press on Mechanical Variables.

    Science.gov (United States)

    Moir, Gavin L; Munford, Shawn N; Moroski, Lindsey L; Davis, Shala E

    2017-02-21

    To investigate the effects of ballistic and non-ballistic bench press performed with loads equivalent to 30 and 90% 1-repetition maximum (1-RM) on mechanical variables. Eleven resistance-trained men (age: 23.0 ± 1.4 years; mass: 98.4 ± 14.4 kg) attended four testing sessions where they performed one of the following sessions: 1) three sets of five non-ballistic repetitions performed with a load equivalent to 30% 1-RM (30N-B), 2) three sets of five ballistic repetitions performed with a load equivalent to 30% 1-RM (30B), 3) three sets of four non-ballistic repetitions with a load equivalent to 90% 1-RM (90N-B), 4) three sets of four ballistic repetitions with a load equivalent to 90% 1-RM (90B). Force plates and a 3-D motion analysis system were used to determine the velocity, force, power output (PO) and work during each repetition. The heavier loads resulted in significantly greater forces applied to the barbell (mean differences: 472-783 N, pvelocities (mean differences: 0.85-1.20 m/s, pvelocity (mean difference: 0.33 m/s, pbench press may be an effective exercise for developing power output and multiple sets may elicit post-activation potentiation that enhances force production. However, these benefits may be negated at heavier loads.

  2. Calibration Transfer Between a Bench Scanning and a Submersible Diode Array Spectrophotometer for In Situ Wastewater Quality Monitoring in Sewer Systems.

    Science.gov (United States)

    Brito, Rita S; Pinheiro, Helena M; Ferreira, Filipa; Matos, José S; Pinheiro, Alexandre; Lourenço, Nídia D

    2016-03-01

    Online monitoring programs based on spectroscopy have a high application potential for the detection of hazardous wastewater discharges in sewer systems. Wastewater hydraulics poses a challenge for in situ spectroscopy, especially when the system includes storm water connections leading to rapid changes in water depth, velocity, and in the water quality matrix. Thus, there is a need to optimize and fix the location of in situ instruments, limiting their availability for calibration. In this context, the development of calibration models on bench spectrophotometers to estimate wastewater quality parameters from spectra acquired with in situ instruments could be very useful. However, spectra contain information not only from the samples, but also from the spectrophotometer generally invalidating this approach. The use of calibration transfer methods is a promising solution to this problem. In this study, calibration models were developed using interval partial least squares (iPLS), for the estimation of total suspended solids (TSS) and chemical oxygen demand (COD) in sewage from Ultraviolet-visible spectra acquired in a bench scanning spectrophotometer. The feasibility of calibration transfer to a submersible, diode array equipment, to be subsequently operated in situ, was assessed using three procedures: slope and bias correction (SBC); single wavelength standardization (SWS) on mean spectra; and local centering (LC). The results showed that SBC was the most adequate for the available data, adding insignificant error to the base model estimates. Single wavelength standardization was a close second best, potentially more robust, and independent of the base iPLS model. Local centering was shown to be inadequate for the samples and instruments used. © The Author(s) 2016.

  3. Sequentially and alternatively developed heights for two representative bench marks: near Palmdale, California and along the Bill Williams River, Arizona

    Science.gov (United States)

    Gilmore, Thomas D.; Elliot, Michael R.

    1985-01-01

    This report consists chiefly of 41 tables that both describe and fully document the reconstructions of a series of alternately developed heights based on levelings leading into two representative bench marks in the southwestern United States. One of these marks, 3219, Vincent, California (fig. 1), lies within the area of the Pacific-North American plate boundary; the other, 22Q, Bill Williams River, Arizona (fig. 1), falls within what is believed to be a singularly stable section of southwestern Arizona. Because the levelings that produced these heights were characterized by especially disparate routes with respect to both terrain and climate, the resulting heights provide a test for the existence and magnitude of path-dependent error in geodetic leveling. These two marks were chosen both because of their relative stability with respect to adjacent marks and because their tectonic stability (or instability) can be inferred from the geologic record. Specifically, we can reasonably speculate that 3219 may have sustained measurably significant tectonic displacements during the 20th century, whereas 22Q probably has remained virtually invariant with respect to any fixed datum during the same period. Bench mark 3219 is a standard Geological Survey iron post stamped "3219" near the Southern Pacific Railroad station at Vincent (U.S. Geological Survey, 1898, p. 392); 22Q is a brass cap stamped "22Q (MWD)" set in a concrete post located in a gully immediately north of the Bill Williams River, Arizona (USC&GS Quad. 34114). 3219 was established by the Geological Survey no later than 1897 (Gannett and Baldwin, 1907, p. 365); 22Q was established by the Metropolitan Water District of southern California in advance of the 1931 control surveys along the projected route of the Colorado River Aqueduct.

  4. Prometeo: A portable test-bench for the upgraded front-end electronics of the ATLAS Tile calorimeter

    CERN Document Server

    Bullock, D; The ATLAS collaboration; Govender, M; Hofsajer, I; Mellado, B; Moreno, P; Reed, R; Ruan, X; Sandrock, C; Solans, C; Suter, R; Usai, G; Valero, A

    2014-01-01

    Prometeo is a portable test-bench for full certification of the front-end electronics of the ATLAS Tile calorimeter, designed for the upgrade phase-II. It is a high-throughput electronic system designed to simultaneously read out all the digitized samples from 12 channels at the LHC bunch crossing frequency and assess the quality of the data in real-time. The core of the system is a Xilinx Virtex 7 evaluation board extended with a dual QSFP FMC module to read out and control the on-detector electronics. The rest of the functionalities of the system are provided by a HV mezzanine board that supplied the HV to the photo-multipliers, an LED board that sends light to illuminate them, and a 12 channel ADC board that samples the analog trigger output of the front- end. The system is connected by ethernet to a GUI client from which QA tests are performed on the electronics such as noise measurements and linearity response to an injected charge.

  5. Prometeo: A portable test-bench for the upgraded front-end electronics of the ATLAS Tile calorimeter

    CERN Document Server

    Bullock, D; The ATLAS collaboration; Hofsajer, I; Govender, M; Mellado, B; Moreno, P; Reed, R; Ruan, X; Sandrock, C; Solans, C; Suter, R; Usai, G; Valero, A

    2014-01-01

    Prometeo is the portable test-bench for the full certification of the front-end electronics of the ATLAS Tile calorimeter designed for the upgrade phase-II. It is a high throughput electronics system designed to simultaneously read-out all the samples from 12 channels at the LHC bunch crossing frequency and assess the quality of the data in real-time. The core of the system is a Xilinx Virtex 7 evaluation board extended with a dual QSFP FMC module to read-out and control the front-end boards. The rest of the functionalities of the system are provided by a HV mezzanine board that to turn on the gain of the photo-multipliers, an LED board that sends light to illuminate them, and a 12 channel ADC board that samples the analog output of the front-end. The system is connected by ethernet to a GUI client from which QA tests are performed on the electronics such as noise measurements and linearity response to an injected charge.

  6. A bench-top hyperspectral imaging system to classify beef from Nellore cattle based on tenderness

    Science.gov (United States)

    Nubiato, Keni Eduardo Zanoni; Mazon, Madeline Rezende; Antonelo, Daniel Silva; Calkins, Chris R.; Naganathan, Govindarajan Konda; Subbiah, Jeyamkondan; da Luz e Silva, Saulo

    2018-03-01

    The aim of this study was to evaluate the accuracy of classification of Nellore beef aged for 0, 7, 14, or 21 days and classification based on tenderness and aging period using a bench-top hyperspectral imaging system. A hyperspectral imaging system (λ = 928-2524 nm) was used to collect hyperspectral images of the Longissimus thoracis et lumborum (aging n = 376 and tenderness n = 345) of Nellore cattle. The image processing steps included selection of region of interest, extraction of spectra, and indentification and evalution of selected wavelengths for classification. Six linear discriminant models were developed to classify samples based on tenderness and aging period. The model using the first derivative of partial absorbance spectra (give wavelength range spectra) was able to classify steaks based on the tenderness with an overall accuracy of 89.8%. The model using the first derivative of full absorbance spectra was able to classify steaks based on aging period with an overall accuracy of 84.8%. The results demonstrate that the HIS may be a viable technology for classifying beef based on tenderness and aging period.

  7. Treatment studies of plutonium-bearing INEEL waste surrogates in a bench-scale arc furnace

    International Nuclear Information System (INIS)

    Freeman, C.J.

    1997-05-01

    Since 1989, the Subsurface Disposal Area (SDA) at the Idaho National Environmental and Engineering Laboratory (INEEL) has been included on the National Priority List for remediation. Arc- and plasma-heated furnaces are being considered for converting the radioactive mixed waste buried in the SDA to a stabilized-vitreous form. Nonradioactive, surrogate SDA wastes have been melted during tests in these types of furnaces, but data are needed on the behavior of transuranic (TRU) constituents, primarily plutonium, during thermal treatment. To begin collecting this data, plutonium-spiked SDA surrogates were processed in a bench-scale arc furnace to quantify the fate of the plutonium and other hazardous and nonhazardous metals. Test conditions included elevating the organic, lead, chloride, and sodium contents of the surrogates. Blends having higher organic contents caused furnace power levels to fluctuate. An organic content corresponding to 50% INEEL soil in a soil-waste blend was the highest achievable before power fluctuations made operating conditions unacceptable. The glass, metal, and off-gas solids produced from each surrogate blend tested were analyzed for elemental (including plutonium) content and the partitioning of each element to the corresponding phase was calculated

  8. 100 Area soil washing: Bench scale tests on 116-F-4 pluto crib soil

    International Nuclear Information System (INIS)

    Field, J.G.

    1994-01-01

    The Pacific Northwest Laboratory conducted a bench-scale treatability study on a pluto crib soil sample from 100 Area of the Hanford Site. The objective of this study was to evaluate the use of physical separation (wet sieving), treatment processes (attrition scrubbing, and autogenous surface grinding), and chemical extraction methods as a means of separating radioactively-contaminated soil fractions from uncontaminated soil fractions. The soil washing treatability study was conducted on a soil sample from the 116-F-4 Pluto Crib that had been dug up as part of an excavation treatability study. Trace element analyses of this soil showed no elevated concentrations above typically uncontaminated soil background levels. Data on the distribution of radionuclide in various size fractions indicated that the soil-washing tests should be focused on the gravel and sand fractions of the 116-F-4 soil. The radionuclide data also showed that 137 Cs was the only contaminant in this soil that exceeded the test performance goal (TPG). Therefore, the effectiveness of subsequent soil-washing tests for 116-F-4 soil was evaluated on the basis of activity attenuation of 137 Cs in the gravel- and sand-size fractions

  9. Bench test evaluation of volume delivered by modern ICU ventilators during volume-controlled ventilation.

    Science.gov (United States)

    Lyazidi, Aissam; Thille, Arnaud W; Carteaux, Guillaume; Galia, Fabrice; Brochard, Laurent; Richard, Jean-Christophe M

    2010-12-01

    During volume-controlled ventilation, part of the volume delivered is compressed into the circuit. To correct for this phenomenon, modern ventilators use compensation algorithms. Humidity and temperature also influence the delivered volume. In a bench study at a research laboratory in a university hospital, we compared nine ICU ventilators equipped with compensation algorithms, one with a proximal pneumotachograph and one without compensation. Each ventilator was evaluated under normal, obstructive, and restrictive conditions of respiratory mechanics. For each condition, three tidal volumes (V (T)) were set (300, 500, and 800 ml), with and without an inspiratory pause. The insufflated volume and the volume delivered at the Y-piece were measured independently, without a humidification device, under ambient temperature and pressure and dry gas conditions. We computed the actually delivered V (T) to the lung under body temperature and pressure and saturated water vapour conditions (BTPS). For target V (T) values of 300, 500, and 800 ml, actually delivered V (T) under BTPS conditions ranged from 261 to 396 ml (-13 to +32%), from 437 to 622 ml (-13 to +24%), and from 681 to 953 ml (-15 to +19%), respectively (p ventilators.

  10. 100 Area soil washing: Bench scale tests on 116-F-4 pluto crib soil

    Energy Technology Data Exchange (ETDEWEB)

    Field, J.G.

    1994-06-10

    The Pacific Northwest Laboratory conducted a bench-scale treatability study on a pluto crib soil sample from 100 Area of the Hanford Site. The objective of this study was to evaluate the use of physical separation (wet sieving), treatment processes (attrition scrubbing, and autogenous surface grinding), and chemical extraction methods as a means of separating radioactively-contaminated soil fractions from uncontaminated soil fractions. The soil washing treatability study was conducted on a soil sample from the 116-F-4 Pluto Crib that had been dug up as part of an excavation treatability study. Trace element analyses of this soil showed no elevated concentrations above typically uncontaminated soil background levels. Data on the distribution of radionuclide in various size fractions indicated that the soil-washing tests should be focused on the gravel and sand fractions of the 116-F-4 soil. The radionuclide data also showed that {sup 137}Cs was the only contaminant in this soil that exceeded the test performance goal (TPG). Therefore, the effectiveness of subsequent soil-washing tests for 116-F-4 soil was evaluated on the basis of activity attenuation of {sup 137}Cs in the gravel- and sand-size fractions.

  11. Effect of rest interval length on bench press performance in boys, teens, and men.

    Science.gov (United States)

    Faigenbaum, Avery D; Ratamess, Nicholas A; McFarland, Jim; Kaczmarek, Jon; Coraggio, Michael J; Kang, Jie; Hoffman, Jay R

    2008-11-01

    The purpose of this study was to assess the lifting performance of boys (N = 12; age 11.3 +/- 0.8 yr), teens (N = 13; age 13.6 +/- 0.6 yr), and men (N = 17; age 21.4 +/- 2.1 yr) to various rest interval (RI) lengths on the bench press exercise. Each subject performed 3 sets with a 10 repetition maximum load and a 1, 2, and 3 min RI between sets. Significant differences in lifting performance between age groups were observed within each RI for selected sets with boys and teens performing significantly more total repetitions than adults following protocols with 1 min (27.9 +/- 3.1, 26.9 +/- 3.9, and 18.2 +/- 4.1, respectively), 2 min (29.6 +/- 1.0, 27.8 +/- 3.5, and 21.4 +/- .1, respectively) and 3 min (30.0 +/- 0.0, 28.8 +/- 2.4, and 23.9 +/- 5.3, respectively) RIs. Significant differences in average velocity and average power between age groups were also observed. These findings indicate that boys and teens are better able to maintain muscle performance during intermittent moderate-intensity resistance exercise as compared with men.

  12. Treatment studies of plutonium-bearing INEEL waste surrogates in a bench-scale arc furnace

    Energy Technology Data Exchange (ETDEWEB)

    Freeman, C.J.

    1997-05-01

    Since 1989, the Subsurface Disposal Area (SDA) at the Idaho National Environmental and Engineering Laboratory (INEEL) has been included on the National Priority List for remediation. Arc- and plasma-heated furnaces are being considered for converting the radioactive mixed waste buried in the SDA to a stabilized-vitreous form. Nonradioactive, surrogate SDA wastes have been melted during tests in these types of furnaces, but data are needed on the behavior of transuranic (TRU) constituents, primarily plutonium, during thermal treatment. To begin collecting this data, plutonium-spiked SDA surrogates were processed in a bench-scale arc furnace to quantify the fate of the plutonium and other hazardous and nonhazardous metals. Test conditions included elevating the organic, lead, chloride, and sodium contents of the surrogates. Blends having higher organic contents caused furnace power levels to fluctuate. An organic content corresponding to 50% INEEL soil in a soil-waste blend was the highest achievable before power fluctuations made operating conditions unacceptable. The glass, metal, and off-gas solids produced from each surrogate blend tested were analyzed for elemental (including plutonium) content and the partitioning of each element to the corresponding phase was calculated.

  13. Bench-scale experimental determination of the thermal diffusivity of crushed tuff

    International Nuclear Information System (INIS)

    Ryder, E.E.; Finley, R.E.; George, J.T.; Ho, C.K.; Longenbaugh, R.S.; Connolly, J.R.

    1996-06-01

    A bench-scale experiment was designed and constructed to determine the effective thermal diffusivity of crushed tuff. Crushed tuff particles ranging from 12.5 mm to 37.5 mm (0.5 in. to 1.5 in.) were used to fill a cylindrical volume of 1.58 m 3 at an effective porosity of 0.48. Two iterations of the experiment were completed; the first spanning approximately 502 hours and the second 237 hours. Temperatures near the axial heater reached 700 degrees C, with a significant volume of the test bed exceeding 100 degrees C. Three post-test analysis techniques were used to estimate the thermal diffusivity of the crushed tuff. The first approach used nonlinear parameter estimation linked to a one dimensional radial conduction model to estimate thermal diffusivity from the first 6 hours of test data. The second method used the multiphase TOUGH2 code in conjunction with the first 20 hours of test data not only to estimate the crushed tuffs thermal diffusivity, but also to explore convective behavior within the test bed. Finally, the nonlinear conduction code COYOTE-II was used to determine thermal properties based on 111 hours of cool-down data. The post-test thermal diffusivity estimates of 5.0 x 10-7 m 2 /s to 6.6 x 10-7 m 2 /s were converted to effective thermal conductivities and compared to estimates obtained from published porosity-based relationships. No obvious match between the experimental data and published relationships was found to exist; however, additional data for other particle sizes and porosities are needed

  14. CPAP Devices for Emergency Prehospital Use: A Bench Study.

    Science.gov (United States)

    Brusasco, Claudia; Corradi, Francesco; De Ferrari, Alessandra; Ball, Lorenzo; Kacmarek, Robert M; Pelosi, Paolo

    2015-12-01

    CPAP is frequently used in prehospital and emergency settings. An air-flow output minimum of 60 L/min and a constant positive pressure are 2 important features for a successful CPAP device. Unlike hospital CPAP devices, which require electricity, CPAP devices for ambulance use need only an oxygen source to function. The aim of the study was to evaluate and compare on a bench model the performance of 3 orofacial mask devices (Ventumask, EasyVent, and Boussignac CPAP system) and 2 helmets (Ventukit and EVE Coulisse) used to apply CPAP in the prehospital setting. A static test evaluated air-flow output, positive pressure applied, and FIO2 delivered by each device. A dynamic test assessed airway pressure stability during simulated ventilation. Efficiency of devices was compared based on oxygen flow needed to generate a minimum air flow of 60 L/min at each CPAP setting. The EasyVent and EVE Coulisse devices delivered significantly higher mean air-flow outputs compared with the Ventumask and Ventukit under all CPAP conditions tested. The Boussignac CPAP system never reached an air-flow output of 60 L/min. The EasyVent had significantly lower pressure excursion than the Ventumask at all CPAP levels, and the EVE Coulisse had lower pressure excursion than the Ventukit at 5, 15, and 20 cm H2O, whereas at 10 cm H2O, no significant difference was observed between the 2 devices. Estimated oxygen consumption was lower for the EasyVent and EVE Coulisse compared with the Ventumask and Ventukit. Air-flow output, pressure applied, FIO2 delivered, device oxygen consumption, and ability to maintain air flow at 60 L/min differed significantly among the CPAP devices tested. Only the EasyVent and EVE Coulisse achieved the required minimum level of air-flow output needed to ensure an effective therapy under all CPAP conditions. Copyright © 2015 by Daedalus Enterprises.

  15. ESCRIME: testing bench for advanced operator workstations in future plants

    International Nuclear Information System (INIS)

    Poujol, A.; Papin, B.

    1994-01-01

    The problem of optimal task allocation between man and computer for the operation of nuclear power plants is of major concern for the design of future plants. As the increased level of automation induces the modification of the tasks actually devoted to the operator in the control room, it is very important to anticipate these consequences at the plant design stage. The improvement of man machine cooperation is expected to play a major role in minimizing the impact of human errors on plant safety. The CEA has launched a research program concerning the evolution of the plant operation in order to optimize the efficiency of the human/computer systems for a better safety. The objective of this program is to evaluate different modalities of man-machine share of tasks, in a representative context. It relies strongly upon the development of a specific testing facility, the ESCRIME work bench, which is presented in this paper. It consists of an EDF 1300MWe PWR plant simulator connected to an operator workstation. The plant simulator model presents at a significant level of details the instrumentation and control of the plant and the main connected circuits. The operator interface is based on the generalization of the use of interactive graphic displays, and is intended to be consistent to the tasks to be performed by the operator. The functional architecture of the workstation is modular, so that different cooperation mechanisms can be implemented within the same framework. It is based on a thorough analysis and structuration of plant control tasks, in normal as well as in accident situations. The software architecture design follows the distributed artificial intelligence approach. Cognitive agents cooperate in order to operate the process. The paper presents the basic principles and the functional architecture of the test bed and describes the steps and the present status of the program. (author)

  16. DECOVALEX I - Bench-Mark Test 3: Thermo-hydro-mechanical modelling

    International Nuclear Information System (INIS)

    Israelsson, J.

    1995-12-01

    The bench-mark test concerns the excavation of a tunnel, located 500 m below the ground surface, and the establishment of mechanical equilibrium and steady-state fluid flow. Following this, a thermal heating due to the nuclear waste, stored in a borehole below the tunnel, was simulated. The results are reported at (1) 30 days after tunnel excavation, (2) steady state, (3) one year after thermal loading, and (4) at the time of maximum temperature. The problem specification included the excavation and waste geometry, materials properties for intact rock and joints, location of more than 6500 joints observed in the 50 by 50 m area, and calculated hydraulic conductivities. However, due to the large number of joints and the lack of dominating orientations, it was decided to treat the problem as a continuum using the computer code FLAC. The problem was modeled using a vertical symmetry plane through the tunnel and the borehole. Flow equilibrium was obtained approx. 40 days after the opening of the tunnel. Since the hydraulic conductivity was set to be stress dependent, a noticeable difference in the horizontal and vertical conductivity and flow was observed. After 40 days, an oedometer-type consolidation of the model was observed. Approx. 4 years after the initiation of the heat source, a maximum temperature of 171 C was obtained. The stress-dependent hydraulic conductivity and the temperature-dependent dynamic viscosity caused minor changes to the flow pattern. The specified mechanical boundary conditions imply that the tunnel is part of a system of parallel tunnels. However, the fixed temperature at the top boundary maintains the temperature below the temperature anticipated for an equivalent repository. The combination of mechanical and hydraulic boundary conditions cause the model to behave like an oedometer test in which the consolidation rate goes asymptotically to zero. 17 refs, 55 figs, 22 tabs

  17. Study of a stand alone power system based on a photovoltaic field, an electrolyser and a fuel cell: test bench and modelling; Etude d'un systeme autonome de production d'energie couplant un champ photovoltaique, un electrolyseur et une pile a combustible: realisation d'un banc d'essai et modelisation

    Energy Technology Data Exchange (ETDEWEB)

    Busquet, S.

    2003-12-01

    Our energetic future has to be based on non-polluting energies with long-term resources. Renewable energies are the best candidates but as their production is intermittent, storage way is necessary as well efficient as environmentally friendly. Coupled an electrolyser and a fuel cell allows to store electricity in gas form and furthermore to produce heat energy. The goal of this work is to evaluate performances of a stand-alone power system, producing electricity and heat, coupling a photovoltaic field and a hydrogen storage system, made of an electrolyser, a gas storage unit and a fuel cell. Hydrogen is the unique way to store electricity. To complete this task, two tools have been developed: a 3,6 kW test bench and a simulation tool. To select the test bench, a bibliographic study enables to collect the necessary information to size and to choice the system and its components. The low availability of components adapted to our application, forces us to create new devices (electrolyser, fuel cell, power management unit). The test bench is automatic and safe. Experimental analysis evaluates the efficiency of the hydrogen storage system, determining the different losses occurring in each component. Modifications are proposed to increase the performances of the storage system. The simulation tool enables to plan the operating of the test bench for a fixed load and place. This model can simulate any system based on experimental data of each component. Simulation results enable to characterise the functioning of the test bench in a stand-alone operation, to determine its performances and to evaluate the influence of the different losses. (author)

  18. The Acute Effect of Upper-Body Complex Training on Power Output of Martial Art Athletes as Measured by the Bench Press Throw Exercise

    Science.gov (United States)

    Liossis, Loudovikos Dimitrios; Forsyth, Jacky; Liossis, Ceorge; Tsolakis, Charilaos

    2013-01-01

    The purpose of this study was to examine the acute effect of upper body complex training on power output, as well as to determine the requisite preload intensity and intra-complex recovery interval needed to induce power output increases. Nine amateur-level combat/martial art athletes completed four distinct experimental protocols, which consisted of 5 bench press repetitions at either: 65% of one-repetition maximum (1RM) with a 4 min rest interval; 65% of 1RM with an 8 min rest; 85% of 1RM with a 4 min rest; or 85% of 1RM with an 8 min rest interval, performed on different days. Before (pre-conditioning) and after (post-conditioning) each experimental protocol, three bench press throws at 30% of 1RM were performed. Significant differences in power output pre-post conditioning were observed across all experimental protocols (F=26.489, partial eta2=0.768, p=0.001). Mean power output significantly increased when the preload stimulus of 65% 1RM was matched with 4 min of rest (p=0.001), and when the 85% 1RM preload stimulus was matched with 8 min of rest (p=0.001). Moreover, a statistically significant difference in power output was observed between the four conditioning protocols (F= 21.101, partial eta2=0.913, p=0.001). It was concluded that, in complex training, matching a heavy preload stimulus with a longer rest interval, and a lighter preload stimulus with a shorter rest interval is important for athletes wishing to increase their power production before training or competition. PMID:24511352

  19. Mean Velocity vs. Mean Propulsive Velocity vs. Peak Velocity: Which Variable Determines Bench Press Relative Load With Higher Reliability?

    Science.gov (United States)

    García-Ramos, Amador; Pestaña-Melero, Francisco L; Pérez-Castilla, Alejandro; Rojas, Francisco J; Gregory Haff, G

    2018-05-01

    García-Ramos, A, Pestaña-Melero, FL, Pérez-Castilla, A, Rojas, FJ, and Haff, GG. Mean velocity vs. mean propulsive velocity vs. peak velocity: which variable determines bench press relative load with higher reliability? J Strength Cond Res 32(5): 1273-1279, 2018-This study aimed to compare between 3 velocity variables (mean velocity [MV], mean propulsive velocity [MPV], and peak velocity [PV]): (a) the linearity of the load-velocity relationship, (b) the accuracy of general regression equations to predict relative load (%1RM), and (c) the between-session reliability of the velocity attained at each percentage of the 1-repetition maximum (%1RM). The full load-velocity relationship of 30 men was evaluated by means of linear regression models in the concentric-only and eccentric-concentric bench press throw (BPT) variants performed with a Smith machine. The 2 sessions of each BPT variant were performed within the same week separated by 48-72 hours. The main findings were as follows: (a) the MV showed the strongest linearity of the load-velocity relationship (median r = 0.989 for concentric-only BPT and 0.993 for eccentric-concentric BPT), followed by MPV (median r = 0.983 for concentric-only BPT and 0.980 for eccentric-concentric BPT), and finally PV (median r = 0.974 for concentric-only BPT and 0.969 for eccentric-concentric BPT); (b) the accuracy of the general regression equations to predict relative load (%1RM) from movement velocity was higher for MV (SEE = 3.80-4.76%1RM) than for MPV (SEE = 4.91-5.56%1RM) and PV (SEE = 5.36-5.77%1RM); and (c) the PV showed the lowest within-subjects coefficient of variation (3.50%-3.87%), followed by MV (4.05%-4.93%), and finally MPV (5.11%-6.03%). Taken together, these results suggest that the MV could be the most appropriate variable for monitoring the relative load (%1RM) in the BPT exercise performed in a Smith machine.

  20. Mechanical and Metabolic Responses to Traditional and Cluster Set Configurations in the Bench Press Exercise.

    Science.gov (United States)

    García-Ramos, Amador; González-Hernández, Jorge M; Baños-Pelegrín, Ezequiel; Castaño-Zambudio, Adrián; Capelo-Ramírez, Fernando; Boullosa, Daniel; Haff, Guy G; Jiménez-Reyes, Pedro

    2017-10-20

    García-Ramos, A, González-Hernández, JM, Baños-Pelegrín, E, Castaño-Zambudio, A, Capelo-Ramírez, F, Boullosa, D, Haff, GG, and Jiménez-Reyes, P. Mechanical and metabolic responses to traditional and cluster set configurations in the bench press exercise. J Strength Cond Res XX(X): 000-000, 2017-This study aimed to compare mechanical and metabolic responses between traditional (TR) and cluster (CL) set configurations in the bench press exercise. In a counterbalanced randomized order, 10 men were tested with the following protocols (sets × repetitions [inter-repetition rest]): TR1: 3 × 10 (0-second), TR2: 6 × 5 (0-second), CL5: 3 × 10 (5-second), CL10: 3 × 10 (10-second), and CL15: 3 × 10 (15-second). The number of repetitions (30), interset rest (5 minutes), and resistance applied (10 repetition maximum) were the same for all set configurations. Movement velocity and blood lactate concentration were used to assess the mechanical and metabolic responses, respectively. The comparison of the first and last set of the training session revealed a significant decrease in movement velocity for TR1 (Effect size [ES]: -0.92), CL10 (ES: -0.85), and CL15 (ES: -1.08) (but not for TR2 [ES: -0.38] and CL5 [ES: -0.37]); while blood lactate concentration was significantly increased for TR1 (ES: 1.11), TR2 (ES: 0.90), and CL5 (ES: 1.12) (but not for CL10 [ES: 0.03] and CL15 [ES: -0.43]). Based on velocity loss, set configurations were ranked as follows: TR1 (-39.3 ± 7.3%) > CL5 (-20.2 ± 14.7%) > CL10 (-12.9 ± 4.9%), TR2 (-10.3 ± 5.3%), and CL15 (-10.0 ± 2.3%). The set configurations were ranked as follows based on the lactate concentration: TR1 (7.9 ± 1.1 mmol·L) > CL5 (5.8 ± 0.9 mmol·L) > TR2 (4.2 ± 0.7 mmol·L) > CL10 (3.5 ± 0.4 mmol·L) and CL15 (3.4 ± 0.7 mmol·L). These results support the use of TR2, CL10, and CL15 for the maintenance of high mechanical outputs, while CL10 and CL15 produce less metabolic stress than TR2.

  1. Appling hydrolysis acidification-anoxic–oxic process in the treatment of petrochemical wastewater: From bench scale reactor to full scale wastewater treatment plant

    International Nuclear Information System (INIS)

    Wu, Changyong; Zhou, Yuexi; Sun, Qingliang; Fu, Liya; Xi, Hongbo; Yu, Yin; Yu, Ruozhen

    2016-01-01

    Highlights: • Hydrolysis acidification-anoxic–oxic process can be used to treat petrochemical wastewater. • The toxicity and treatability changed significantly after hydrolysis acidification. • The type and concentration of organics reduced greatly after treatment. • The effluent shows low acute toxicity by luminescent bacteria assay. • Advanced treatment is recommended for the effluent. - Abstract: A hydrolysis acidification (HA)-anoxic–oxic (A/O) process was adopted to treat a petrochemical wastewater. The operation optimization was carried out firstly by a bench scale experimental reactor. Then a full scale petrochemical wastewater treatment plant (PCWWTP, 6500 m 3 h −1 ) was operated with the same parameters. The results showed that the BOD 5 /COD of the wastewater increased from 0.30 to 0.43 by HA. The effluent COD was 54.4 mg L −1 for bench scale reactor and 60.9 mg L −1 for PCWWTP when the influent COD was about 480 mg L −1 on optimized conditions. The organics measured by gas chromatography-mass spectrometry (GC–MS) reduced obviously and the total concentration of the 5 organics (1,3-dioxolane, 2-pentanone, ethylbenzene, 2-chloromethyl-1,3-dioxolane and indene) detected in the effluent was only 0.24 mg L −1 . There was no obvious toxicity of the effluent. However, low acute toxicity of the effluent could be detected by the luminescent bacteria assay, indicating the advanced treatment is needed. The clone library profiling analysis showed that the dominant bacteria in the system were Acidobacteria, Proteobacteria and Bacteriodetes. HA-A/O process is suitable for the petrochemical wastewater treatment.

  2. A computational methodology for a micro launcher engine test bench using a combined linear static and dynamic in frequency response analysis

    Directory of Open Access Journals (Sweden)

    Ion DIMA

    2017-03-01

    Full Text Available This article aims to provide a quick methodology to determine the critical values of the forces, displacements and stress function of frequency, under a combined linear static (101 Solution - Linear Static and dynamic load in frequency response (108 Solution - Frequency Response, Direct Method, applied to a micro launcher engine test bench, using NASTRAN 400 Solution - Implicit Nonlinear. NASTRAN/PATRAN software is used. Practically in PATRAN the preprocessor has to define a linear or nonlinear static load at step 1 and a dynamic in frequency response load (time dependent at step 2. In Analyze the following options are chosen: for Solution Type Implicit Nonlinear Solution (SOL 400 is selected, for Subcases Static Load and Transient Dynamic is chosen and for Subcase Select the two cases static and dynamic will be selected. NASTRAN solver will overlap results from static analysis with the dynamic analysis. The running time will be reduced three times if using Krylov solver. NASTRAN SYSTEM (387 = -1 instruction is used in order to activate Krylov option. Also, in Analysis the OP2 Output Format shall be selected, meaning that in bdf NASTRAN input file the PARAM POST 1 instruction shall be written. The structural damping can be defined in two different ways: either at the material card or using the PARAM, G, 0.05 instruction (in this example a damping coefficient by 5% was used. The SDAMPING instruction in pair with TABDMP1 work only for dynamic in frequency response, modal method, or in direct method with viscoelastic material, not for dynamic in frequency response, direct method (DFREQ, with linear elastic material. The Direct method – DFREQ used in this example is more accurate. A set in translation of boundary conditions was used and defined at the base of the test bench.

  3. Comparison of different cryogenic control strategies via simulation applied to a superconducting magnet test bench at CERN

    Science.gov (United States)

    Arpaia, P.; Coppier, H.; De Paola, D.; di Bernardo, M.; Guarino, A.; Pedemonte, B. Luz; Pezzetti, M.

    2017-12-01

    Industrial process controllers for cryogenic systems used in test facilities for superconducting magnets are typically PIDs, tuned by operational expertise according to users’ requirements (covering cryogenic transients and associated thermo-mechanical constraints). In this paper, an alternative fully-automatic solution, equally based on PID controllers, is proposed. Following the comparison of the operational expertise and alternative fully-automatic approaches, a new process control configuration, based on an estimated multiple-input/multiple-output (MIMO) model is proposed. The new MIMO model-based approach fulfils the required operational constraints while improving performance compared to existing solutions. The analysis and design work is carried out using both theoretical and numerical tools and is validated on the case study of the High Field Magnet (HFM) cryogenic test bench running at the SM18 test facility located at CERN. The proposed solution have been validated by simulation using the CERN ECOSIMPRO software tools using the cryogenic library (CRYOLIB [1]) developed at CERN.

  4. Domestic Wastewater Reuse in Concrete Using Bench-Scale Testing and Full-Scale Implementation

    Directory of Open Access Journals (Sweden)

    Ayoup M. Ghrair

    2016-08-01

    Full Text Available Demand for fresh water by the construction sector is expected to increase due to the high increase in the growth of construction activities in Jordan. This study aims to evaluate the potential of scale-up of the application of treated domestic wastewater in concrete from bench-scale to a full-scale. On the lab scale, concrete and mortar mixes using Primary and Secondary Treated Wastewater (PTW, STW and Distilled Water (DW were cast and tested after various curing ages (7, 28, 120, and 200 days. Based on wastewater quality, according to IS 456-2000, the STW is suitable for mortar and concrete production. Mortar made with STW at curing time up to 200 days has no significant negative effect on the mortar’s compressive strength. Conversely, the PTW exceeded the maximum permissible limits of total organic content and E coli. for concrete mixing-water. Using PTW results, a significant increase in the initial setting time of up to 16.7% and a decrease in the concrete workability are observed. In addition, using PTW as mixing water led to a significant reduction in the compressive strength up to 19.6%. The results that came out from scaling up to real production operation of ready-mix concrete were in harmony with the lab-scale results.

  5. Humidification during high-frequency oscillatory ventilation for adults: a bench study.

    Science.gov (United States)

    Chikata, Yusuke; Imanaka, Hideaki; Ueta, Masahiko; Nishimura, Masaji

    2010-12-01

    High-frequency oscillatory ventilation (HFOV) has recently been applied to acute respiratory distress syndrome patients. However, the issue of humidification during HFOV has not been investigated. In a bench study, we evaluated humidification during HFOV for adults to test if adequate humidification was achieved in 2 different HFOV systems. We tested 2 brands of adult HFOV ventilators, the R100 (Metran, Japan) and the 3100B (SensorMedics, CA), under identical bias flow. A heated humidifier consisting of porous hollow fiber (Hummax II, Metran) was set for the R100, and a passover-type heated humidifier (MR850, Fisher & Paykel) was set for the 3100B, while inspiratory heating wire was applied to both systems. Each ventilator was connected to a lung model in an incubator. Absolute humidity, relative humidity and temperature at the airway opening were measured using a hygrometer under a variety of ventilatory settings: 3 stroke volumes/amplitudes, 3 frequencies, and 2 mean airway pressures. The R100 ventilator showed higher absolute humidity, higher relative humidity, and lower temperature than the 3100B. In the R100, as stroke volume and frequency increased, absolute humidity and temperature increased. In the 3100B, amplitude, frequency, and mean airway pressure minimally affected absolute humidity and temperature. Relative humidity was almost 100% in the R100, while it was 80.5±2.3% in the 3100B. Humidification during HFOV for adults was affected by stroke volume and frequency in the R100, but was not in the 3100B. Absolute humidity was above 33 mgH_2 O/L in these 2 systems under a range of settings.

  6. Von Willebrand Factor as a Novel Player in Valvular Heart Disease: From Bench to Valve Replacement.

    Science.gov (United States)

    Gragnano, Felice; Crisci, Mario; Bigazzi, Maurizio Cappelli; Bianchi, Renatomaria; Sperlongano, Simona; Natale, Francesco; Fimiani, Fabio; Concilio, Claudia; Cesaro, Arturo; Pariggiano, Ivana; Diana, Vincenzo; Limongelli, Giuseppe; Cirillo, Plinio; Russo, Mariagiovanna; Golia, Enrica; Calabrò, Paolo

    2018-02-01

    von Willebrand Factor (vWF) is a well-known mediator of hemostasis and vascular inflammation. Its dynamic modulation in the bloodstream, according to hemodynamic conditions, makes it an appealing biomarker in patients with valvular heart disease (VHD). Recent studies highlight the close connection between vWF and VHD, with possible implications in the pathogenesis of VHD, promoting valve aging and calcification or favoring the development of infective endocarditis. Moreover, vWF has been recently proposed as a new diagnostic and prognostic tool in patients with valve stenosis or regurgitation, showing a strict correlation with severity of valve disease, outcome, and bleeding (Heyde syndrome). A novel role for vWF is also emerging in patients undergoing percutaneous or surgical valve repair/replacement to select and stratify patients, evaluate periprocedural bleeding risk, and detect procedural complications. We also report our single-center experience, suggesting, for the first time, possible clinical implications for vWF in percutaneous mitral valve repair (MitraClip). This review summarizes recent advances in the role of vWF in VHD with an updated overview going from bench to operating room.

  7. Production of uranium hexafluoride by the catalysed fluorox process: pilot plant and supporting bench-scale studies

    International Nuclear Information System (INIS)

    Janov, J.; Charlton, B.G.; LePage, A.H.; Vilkaitis, V.K.

    1982-04-01

    The feasibility of producing UF 6 by the catalysed reaction of UF 4 with oxygen (the Fluorox process) was investigated in a 150 mm diameter fluidised bed reactor and in supporting bench-scale experiments. The rate of the Fluorox reaction in batch experiments was increased by an order of magnitude with 1 to 5 per cent catalyst (containing 3 to 4 per cent platinum on alumina). The maximum UF 6 production rate at 650 deg. C was 0.9 kg h -1 . However, the platinum catalyst was completely poisoned after production of only 1 and 20 kg UF 6 per kg of catalyst when using respectively French and British UF 4 . Regeneration of the catalyst was demonstrated to be technically feasible by washing with water or ammonium oxalate solution or treating with hydrogen and hydrogen fluoride at 350-650 deg. C. However, since the very fast rate of poisoning would necessitate higher catalyst concentrations and/or frequent regeneration, the catalysed Fluorox process in unlikely to be economically competitive with the direct fluorination of UF 4

  8. Trigger performance of mid-level ICU mechanical ventilators during assisted ventilation: a bench study.

    Science.gov (United States)

    Ferreira, Juliana C; Chipman, Daniel W; Kacmarek, Robert M

    2008-09-01

    To compare the triggering performance of mid-level ICU mechanical ventilators with a standard ICU mechanical ventilator. Experimental bench study. The respiratory care laboratory of a university-affiliated teaching hospital. A computerized mechanical lung model, the IngMar ASL5000. Ten mid-level ICU ventilators were compared to an ICU ventilator at two levels of lung model effort, three combinations of respiratory mechanics (normal, COPD and ARDS) and two modes of ventilation, volume and pressure assist/control. A total of 12 conditions were compared. Performance varied widely among ventilators. Mean inspiratory trigger time was ventilators. The mean inspiratory delay time (time from initiation of the breath to return of airway pressure to baseline) was longer than that for the ICU ventilator for all tested ventilators except one. The pressure drop during triggering (Ptrig) was comparable with that of the ICU ventilator for only two ventilators. Expiratory Settling Time (time for pressure to return to baseline) had the greatest variability among ventilators. Triggering differences among these mid-level ICU ventilators and with the ICU ventilator were identified. Some of these ventilators had a much poorer triggering response with high inspiratory effort than the ICU ventilator. These ventilators do not perform as well as ICU ventilators in patients with high ventilatory demand.

  9. Rapid pyrolysis of wheat straw in a Bench-Scale circulating Fluidized-Bed downer reactor

    Energy Technology Data Exchange (ETDEWEB)

    Ding, T. [State Key Laboratory of Multiphase Complex Systems, Institute of Process Engineering, Chinese Academy of Sciences, Beijing (China); Graduate School of Chinese Academy of Sciences, Beijing (China); Li, S.; Xie, J.; Song, W.; Yao, J.; Lin, W. [State Key Laboratory of Multiphase Complex Systems, Institute of Process Engineering, Chinese Academy of Sciences, Beijing (China)

    2012-12-15

    The effects of acid washing treatment on the pyrolysis product distribution and product properties were investigated in a bench-scale circulating fluidized-bed (CFB) downer reactor with wheat straw as feedstock. The acid treatment not only removes most of the inorganic species present in the biomass but also alters the distribution of the remaining organic constituents. It was found that the removal of the inorganic species increases the yield of liquid product and reduces char formation and gas yield. CO and CO{sub 2} are the dominant components in the gaseous product, accounting for over 90 %. The concentration of CO in the gaseous product increases after acid treatment, while the CO{sub 2} concentration decreases. The oxygen and water contents in the liquid product are decreased on acid treatment, leading to a relatively high heating value and viscosity. More volatiles can be found in the char derived from the acid-treated wheat straw than from the raw wheat straw. This may suggest that a longer residence time is needed for pyrolysis of the acid-treated wheat straw in order to obtain the maximal yield of volatile matter. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  10. GPCR-Bench: A Benchmarking Set and Practitioners' Guide for G Protein-Coupled Receptor Docking.

    Science.gov (United States)

    Weiss, Dahlia R; Bortolato, Andrea; Tehan, Benjamin; Mason, Jonathan S

    2016-04-25

    Virtual screening is routinely used to discover new ligands and in particular new ligand chemotypes for G protein-coupled receptors (GPCRs). To prepare for a virtual screen, we often tailor a docking protocol that will enable us to select the best candidates for further screening. To aid this, we created GPCR-Bench, a publically available docking benchmarking set in the spirit of the DUD and DUD-E reference data sets for validation studies, containing 25 nonredundant high-resolution GPCR costructures with an accompanying set of diverse ligands and computational decoy molecules for each target. Benchmarking sets are often used to compare docking protocols; however, it is important to evaluate docking methods not by "retrospective" hit rates but by the actual likelihood that they will produce novel prospective hits. Therefore, docking protocols must not only rank active molecules highly but also produce good poses that a chemist will select for purchase and screening. Currently, no simple objective machine-scriptable function exists that can do this; instead, docking hit lists must be subjectively examined in a consistent way to compare between docking methods. We present here a case study highlighting considerations we feel are of importance when evaluating a method, intended to be useful as a practitioners' guide.

  11. Simulation of large scale air detritiation operations by computer modeling and bench-scale experimentation

    International Nuclear Information System (INIS)

    Clemmer, R.G.; Land, R.H.; Maroni, V.A.; Mintz, J.M.

    1978-01-01

    Although some experience has been gained in the design and construction of 0.5 to 5 m 3 /s air-detritiation systems, little information is available on the performance of these systems under realistic conditions. Recently completed studies at ANL have attempted to provide some perspective on this subject. A time-dependent computer model was developed to study the effects of various reaction and soaking mechanisms that could occur in a typically-sized fusion reactor building (approximately 10 5 m 3 ) following a range of tritium releases (2 to 200 g). In parallel with the computer study, a small (approximately 50 liter) test chamber was set up to investigate cleanup characteristics under conditions which could also be simulated with the computer code. Whereas results of computer analyses indicated that only approximately 10 -3 percent of the tritium released to an ambient enclosure should be converted to tritiated water, the bench-scale experiments gave evidence of conversions to water greater than 1%. Furthermore, although the amounts (both calculated and observed) of soaked-in tritium are usually only a very small fraction of the total tritium release, the soaked tritium is significant, in that its continuous return to the enclosure extends the cleanup time beyond the predicted value in the absence of any soaking mechanisms

  12. Neonatal and adult ICU ventilators to provide ventilation in neonates, infants, and children: a bench model study.

    Science.gov (United States)

    Vignaux, Laurence; Piquilloud, Lise; Tourneux, Pierre; Jolliet, Philippe; Rimensberger, Peter C

    2014-10-01

    Using a bench test model, we investigated the hypothesis that neonatal and/or adult ventilators equipped with neonatal/pediatric modes currently do not reliably administer pressure support (PS) in neonatal or pediatric patient groups in either the absence or presence of air leaks. PS was evaluated in 4 neonatal and 6 adult ventilators using a bench model to evaluate triggering, pressurization, and cycling in both the absence and presence of leaks. Delivered tidal volumes were also assessed. Three patients were simulated: a preterm infant (resistance 100 cm H2O/L/s, compliance 2 mL/cm H2O, inspiratory time of the patient [TI] 400 ms, inspiratory effort 1 and 2 cm H2O), a full-term infant (resistance 50 cm H2O/L/s, compliance 5 mL/cm H2O, TI 500 ms, inspiratory effort 2 and 4 cm H2O), and a child (resistance 30 cm H2O/L/s, compliance 10 mL/cm H2O, TI 600 ms, inspiratory effort 5 and 10 cm H2O). Two PS levels were tested (10 and 15 cm H2O) with and without leaks and with and without the leak compensation algorithm activated. Without leaks, only 2 neonatal ventilators and one adult ventilator had trigger delays under a given predefined acceptable limit (1/8 TI). Pressurization showed high variability between ventilators. Most ventilators showed TI in excess high enough to seriously impair patient-ventilator synchronization (> 50% of the TI of the subject). In some ventilators, leaks led to autotriggering and impairment of ventilation performance, but the influence of leaks was generally lower in neonatal ventilators. When a noninvasive ventilation algorithm was available, this was partially corrected. In general, tidal volume was calculated too low by the ventilators in the presence of leaks; the noninvasive ventilation algorithm was able to correct this difference in only 2 adult ventilators. No ventilator performed equally well under all tested conditions for all explored parameters. However, neonatal ventilators tended to perform better in the presence of leaks

  13. Bench Scale Development and Testing of Aerogel Sorbents for CO2 Capture Final Technical Report

    Energy Technology Data Exchange (ETDEWEB)

    Begag, Redouane [Aspen Aerogels, Northborough, MA (United States)

    2017-03-30

    The primary objective of this project was scaling up and evaluating a novel Amine Functionalized Aerogel (AFA) sorbent in a bench scale fluidized bed reactor. The project team (Aspen Aerogels, University of Akron, ADA-ES, and Longtail Consulting) has carried out numerous tests and optimization studies to demonstrate the CO2 capture performance of the AFA sorbent in all its forms: powder, pellet, and bead. The CO2 capture target performance of the AFA sorbent (all forms) were set at > 12 wt.% and > 6 wt.% for total and working CO2 capacity, respectively (@ 40 °C adsorption / 100 – 120 °C desorption). The optimized AFA powders outperformed the performance targets by more than 30%, for the total CO2 capacity (14 - 20 wt.%), and an average of 10 % more for working CO2 capacity (6.6 – 7.0 wt.%, and could be as high as 9.6 wt. % when desorbed at 120 °C). The University of Akron developed binder formulations, pellet production methods, and post treatment technology for increased resistance to attrition and flue gas contaminants. In pellet form the AFA total CO2 capacity was ~ 12 wt.% (over 85% capacity retention of that of the powder), and there was less than 13% degradation in CO2 capture capacity after 20 cycles in the presence of 40 ppm SO2. ADA-ES assessed the performance of the AFA powder, pellet, and bead by analyzing sorption isotherms, water uptake analysis, cycling stability, jet cup attrition and crush tests. At bench scale, the hydrodynamic and heat transfer properties of the AFA sorbent pellet in fluidized bed conditions were evaluated at Particulate Solid Research, Inc. (PSRI). After the process design requirements were completed, by Longtail Consulting LLC, a techno-economic analysis was achieved using guidance from The National Energy Technology Laboratory (NETL) report. This report provides the necessary framework to estimate costs for a temperature swing post

  14. Enriched-air fluidized bed gasification using bench and pilot scale reactors of dairy manure with sand bedding based on response surface methods

    International Nuclear Information System (INIS)

    Nam, Hyungseok; Maglinao, Amado L.; Capareda, Sergio C.; Rodriguez-Alejandro, David Aaron

    2016-01-01

    Enriched-air gasification was performed in fluidized bed reactors using the processed dairy manure which was mixed with sand bedding. The effects of temperature, modified equivalence ratio (ER_m), and oxygen concentration on the gas products were investigated based on the statistical models using a bench-scale reactor in order to obtain empirical correlations. Then, the empirical equations were applied to compare the produced gases from a pilot-scale fluidized bed gasifier. The empirical and actual H_2 and CH_4 compositions were within a 10% error, while the sum of produced CO and CO_2 gases showed similar composition within 3% error. The most influential factors for the syngas heating value were temperature followed by the oxygen concentration and ER (equivalence ratio). The composition of H_2 (2.1–11.5%) and CO (5.9–20.3%) rose with an increase in temperature and oxygen concentration. The variation of CO_2 (16.8–31.6%) was mainly affected by the degree of oxygen concentration in the gasifying agent. The ranges of the LHV (lower heating value), carbon conversion efficiency and cold gas efficiency were discussed. An economic review showed favorable indications for on-site dairy manure gasification process for electric power based on the depreciable payback period and the power production costs. - Highlights: • Sand mixed dairy manure obtained directly from a dairy farm was processed and used. • Response surface methodology was used to investigate the enriched-air gasification. • Syngas results from bench and pilot scale gasifiers were compared and reviewed. • A highest LVH of 8 MJ/Nm"3 was obtained from the enriched-air gasification. • The power production costs were determined to be $0.053/kWh

  15. PNNL Report on the Development of Bench-scale CFD Simulations for Gas Absorption across a Wetted Wall Column

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Chao; Xu, Zhijie; Lai, Canhai; Whyatt, Greg A.; Marcy, Peter; Gattiker, J. R.; Sun, Xin

    2016-05-01

    This report is prepared for the demonstration of hierarchical prediction of carbon capture efficiency of a solvent-based absorption column. A computational fluid dynamics (CFD) model is first developed to simulate the core phenomena of solvent-based carbon capture, i.e., the CO2 physical absorption and chemical reaction, on a simplified geometry of wetted wall column (WWC) at bench scale. Aqueous solutions of ethanolamine (MEA) are commonly selected as a CO2 stream scrubbing liquid. CO2 is captured by both physical and chemical absorption using highly CO2 soluble and reactive solvent, MEA, during the scrubbing process. In order to provide confidence bound on the computational predictions of this complex engineering system, a hierarchical calibration and validation framework is proposed. The overall goal of this effort is to provide a mechanism-based predictive framework with confidence bound for overall mass transfer coefficient of the wetted wall column (WWC) with statistical analyses of the corresponding WWC experiments with increasing physical complexity.

  16. Bench-scale studies of reactor-based treatment of fuel-contaminated soils

    International Nuclear Information System (INIS)

    Truax, D.D.; Britto, R.; Sherrard, J.H.

    1995-01-01

    Biological treatment of hazardous wastes from accidental spills or underground storage tank leaks has generated interest in bioremediation as a natural, economical mechanism for site decontamination. Because of drawbacks of batch systems, and the successful use of continuous flow treatment of wastewater for several decades, it was felt that continuous treatment of such soils would be a feasible alternative treatment technique. Therefore, bench-scale bioreactor treatability studies were conducted and used contaminated soil made in the laboratory using No. 2 diesel fuel and sand. Contamination levels studied were from 1,335--6,675 mg (TPH) as derived from No. 2 fuel oil per kg sand. Variation in mean cell age was obtained between reactors, with sufficient nutrients and oxygen made available to ensure the fuel oil organics were the only limit to microbial growth. A theoretical biokinetic model was formulated based on Monod's theory of limiting substrate and continuous cultures. Biokinetic constants and removal efficiencies were evaluated. The off-gases, CO 2 , and volatile hydrocarbons were monitored for mass balance analysis of the process. The solids retention times for evaluating final TPH concentration of 100 mg/kg were also calculated. Removal efficiencies of up to 91% were attained at a loading of 1,335 mg TPH/kg wet sand, operated at a biological solid retention time (BSRT) of 60 days. Experiments also showed that TPH desorption and volatilization were not rate-limiting in the overall removal process. Sand-to-moisture ratios in excess of 3:1 were also shown to retard TPH removal rates very little. However, biokinetic constants were found to vary over a range of values. This was particularly true at varying diesel loading levels. Nevertheless, significant removal efficiency (up to 86%) was noted at the highest loading level tested, 6,675 mg TPH/kg wet sand

  17. Removal of 226Ra from tailings pond effluents and stabilization of uranium mine tailings. Bench and pilot scale studies

    International Nuclear Information System (INIS)

    Schmidtke, N.W.; Averill, D.; Bryant, D.N.; Wilkinson, P.; Schmidt, J.W.

    1978-01-01

    Increased world demand for uranium has resulted in recent expansion of Canadian uranium mining operations. Problems have been identified with the discharge of radionuclides such as 226 Ra from tailings pond effluents and with the stabilization of mine tailings. At Environment Canada's Wastewater Technology Centre (WTC) two projects were undertaken in cooperation with the Canadian Uranium Mining Industry and other federal government agencies to address these problems. The first project reports on the progress of bench and pilot scale process simulations for the development of a data base for the design of a full scale mechanical physical/chemical 226 Ra removal waste treatment system with an effluent target level of 10 pCi 226 Ra total per litre. The second project addresses problems of the leachability of radionuclides and the stabilization of both uranium mine tailings and BaRaSO 4 sediments from the treatment of acid seepages

  18. Performance evaluation of the Abbott CELL-DYN Emerald for use as a bench-top analyzer in a research setting.

    Science.gov (United States)

    Khoo, T-L; Xiros, N; Guan, F; Orellana, D; Holst, J; Joshua, D E; Rasko, J E J

    2013-08-01

    The CELL-DYN Emerald is a compact bench-top hematology analyzer that can be used for a three-part white cell differential analysis. To determine its utility for analysis of human and mouse samples, we evaluated this machine against the larger CELL-DYN Sapphire and Sysmex XT2000iV hematology analyzers. 120 human (normal and abnormal) and 30 mouse (normal and abnormal) samples were analyzed on both the CELL-DYN Emerald and CELL-DYN Sapphire or Sysmex XT2000iV analyzers. For mouse samples, the CELL-DYN Emerald analyzer required manual recalibration based on the histogram populations. Analysis of the CELL-DYN Emerald showed excellent precision, within accepted ranges (white cell count CV% = 2.09%; hemoglobin CV% = 1.68%; platelets CV% = 4.13%). Linearity was excellent (R² ≥ 0.99), carryover was minimal (laboratories or as a backup system in larger laboratories. © 2012 John Wiley & Sons Ltd.

  19. Algal toxins and reverse osmosis desalination operations: Laboratory bench testing and field monitoring of domoic acid, saxitoxin, brevetoxin and okadaic acid

    KAUST Repository

    Seubert, Erica L.

    2012-12-01

    The occurrence and intensity of harmful algal blooms (HABs) have been increasing globally during the past few decades. The impact of these events on seawater desalination facilities has become an important topic in recent years due to enhanced societal interest and reliance on this technology for augmenting world water supplies. A variety of harmful bloom-forming species of microalgae occur in southern California, as well as many other locations throughout the world, and several of these species are known to produce potent neurotoxins. These algal toxins can cause a myriad of human health issues, including death, when ingested via contaminated seafood. This study was designed to investigate the impact that algal toxin presence may have on both the intake and reverse osmosis (RO) desalination process; most importantly, whether or not the naturally occurring algal toxins can pass through the RO membrane and into the desalination product. Bench-scale RO experiments were conducted to explore the potential of extracellular algal toxins contaminating the RO product. Concentrations exceeding maximal values previously reported during natural blooms were used in the laboratory experiments, with treatments comprised of 50 μg/L of domoic acid (DA), 2 μg/L of saxitoxin (STX) and 20 μg/L of brevetoxin (PbTx). None of the algal toxins used in the bench-scale experiments were detectable in the desalinated product water. Monitoring for intracellular and extracellular concentrations of DA, STX, PbTx and okadaic acid (OA) within the intake and desalinated water from a pilot RO desalination plant in El Segundo, CA, was conducted from 2005 to 2009. During the five-year monitoring period, DA and STX were detected sporadically in the intake waters but never in the desalinated water. PbTx and OA were not detected in either the intake or desalinated water. The results of this study demonstrate the potential for HAB toxins to be inducted into coastal RO intake facilities, and the

  20. Algal toxins and reverse osmosis desalination operations: Laboratory bench testing and field monitoring of domoic acid, saxitoxin, brevetoxin and okadaic acid

    KAUST Repository

    Seubert, Erica L.; Trussell, Shane; Eagleton, John; Schnetzer, Astrid; Cetinić, Ivona; Lauri, Phil; Jones, Burton; Caron, David A.

    2012-01-01

    The occurrence and intensity of harmful algal blooms (HABs) have been increasing globally during the past few decades. The impact of these events on seawater desalination facilities has become an important topic in recent years due to enhanced societal interest and reliance on this technology for augmenting world water supplies. A variety of harmful bloom-forming species of microalgae occur in southern California, as well as many other locations throughout the world, and several of these species are known to produce potent neurotoxins. These algal toxins can cause a myriad of human health issues, including death, when ingested via contaminated seafood. This study was designed to investigate the impact that algal toxin presence may have on both the intake and reverse osmosis (RO) desalination process; most importantly, whether or not the naturally occurring algal toxins can pass through the RO membrane and into the desalination product. Bench-scale RO experiments were conducted to explore the potential of extracellular algal toxins contaminating the RO product. Concentrations exceeding maximal values previously reported during natural blooms were used in the laboratory experiments, with treatments comprised of 50 μg/L of domoic acid (DA), 2 μg/L of saxitoxin (STX) and 20 μg/L of brevetoxin (PbTx). None of the algal toxins used in the bench-scale experiments were detectable in the desalinated product water. Monitoring for intracellular and extracellular concentrations of DA, STX, PbTx and okadaic acid (OA) within the intake and desalinated water from a pilot RO desalination plant in El Segundo, CA, was conducted from 2005 to 2009. During the five-year monitoring period, DA and STX were detected sporadically in the intake waters but never in the desalinated water. PbTx and OA were not detected in either the intake or desalinated water. The results of this study demonstrate the potential for HAB toxins to be inducted into coastal RO intake facilities, and the

  1. Bench-scale cross flow filtration of Tank S-107 sludge slurries and Tank C-107 supernatant

    International Nuclear Information System (INIS)

    Geeting, J.G.H.; Reynolds, B.A.

    1996-10-01

    Hanford tank waste filtration experiments were conducted using a bench-scale cross flow filter on 8 wt%, 1.5 wt%, and 0.05 wt% Tank S- 107 sludge slurries and on Tank C-107 supernatant. For comparison, two simulants each with solids loadings of 8 wt% and 0.05 wt% were also tested. The purpose of the tests was to determine the efficacy of cross flow filtration on slurries of various solids loadings. -In addition, filtrate flux dependency on axial velocity and transmembrane pressure was sought so that conditions for future experiments might be better selected. The data gathered are compared to the simulants and three cross flow filtration models. A two- parameter central composite design which tested. transmembrane pressure from 5 to 40 psig and axial Velocity from 3 to 9 ft/s was used for all feeds. The cross flow filter effectively removed solids from the liquid, as 19 of 20 filtrate samples had particle concentrations below the resolution limit of the photon correlation spectrometer used in the Hanford Radiocolloid Laboratory. Radiochemical analysis indicate that all filtrate samples were below Class A waste classification standards for 9OSr and transuranics

  2. Comparison of Portable and Bench-Top Spectrometers for Mid-Infrared Diffuse Reflectance Measurements of Soils.

    Science.gov (United States)

    Hutengs, Christopher; Ludwig, Bernard; Jung, András; Eisele, Andreas; Vohland, Michael

    2018-03-27

    Mid-infrared (MIR) spectroscopy has received widespread interest as a method to complement traditional soil analysis. Recently available portable MIR spectrometers additionally offer potential for on-site applications, given sufficient spectral data quality. We therefore tested the performance of the Agilent 4300 Handheld FTIR (DRIFT spectra) in comparison to a Bruker Tensor 27 bench-top instrument in terms of (i) spectral quality and measurement noise quantified by wavelet analysis; (ii) accuracy of partial least squares (PLS) calibrations for soil organic carbon (SOC), total nitrogen (N), pH, clay and sand content with a repeated cross-validation analysis; and (iii) key spectral regions for these soil properties identified with a Monte Carlo spectral variable selection approach. Measurements and multivariate calibrations with the handheld device were as good as or slightly better than Bruker equipped with a DRIFT accessory, but not as accurate as with directional hemispherical reflectance (DHR) data collected with an integrating sphere. Variations in noise did not markedly affect the accuracy of multivariate PLS calibrations. Identified key spectral regions for PLS calibrations provided a good match between Agilent and Bruker DHR data, especially for SOC and N. Our findings suggest that portable FTIR instruments are a viable alternative for MIR measurements in the laboratory and offer great potential for on-site applications.

  3. Radioactive contamination of the 30-km zone according to the sampling data within bench-marks of gamma-ray survey in 1991

    International Nuclear Information System (INIS)

    Lesnoj, D.A.; Rybalko, S.I.; Solyanek, E.G.

    1992-01-01

    It is noted that formation of radioactive contamination of the Chernobyl' 30-km zone is conditioned by two main factors: state of operation of the reactor and movement of air masses within the period of 26.04.86 till 5.06.86. The analyses of formation of the radioactive traces in this period is presented. It is noted that ground radiometric and spectrometric investigations in 1991 according to the bench-marks with regard to gamma-ray survey of the 30-km zone make it possible to recognize 25% areas as having values close on background rates of the exposure doze in south-western and south-eastern sectors. However, these areas can be recommended for agricultural use after careful geochemical and hydrological mapping and inspecting settlements, plants and animals contamination. 1 tabs

  4. Bench-scale testing of on-line control of column flotation using a novel analyzer. Third quarterly technical progress report, April 1, 1993--June 30, 1993

    Energy Technology Data Exchange (ETDEWEB)

    1993-08-24

    This document contains the third quarterly technical progress report for PTI`s Bench-Scale Testing Project of a circuit integrating PTI`s KEN-FLOTETM Column Flotation Technology and PTI`s On-Line Quality Monitor and Control System. The twelve-month project involves installation and testing of a 200--300 lb/hr. bench-scale flotation circuit at PETC`s Coal Preparation Process Research Facility (CPPRF) for two bituminous coals (Upper Freeport and Pittsburgh No. 8 Seam Raw Coals). Figure 1 contains the project plan, as well as the approach to completing the major tasks within the twelve-month project schedule. The project is broken down into three phases, which include: Phase I -- Preparation: The preparation phase was performed principally at PTI`s Calumet offices from October through December, 1992. It involved building of the equipment and circuitry, as well as some preliminary design and equipment testing; Phase II -- ET Circuit Installation and Testing: This installation and testing phase of the project was performed at PETC`s CPPRF from January through June, 1993, and was the major focus of the project. It involved testing of the continuous 200--300 lb/hr. circuit; and Phase III -- Project Finalization: The project finalization phase is occurring from July through September, 1993, at PTI`s Calumet offices and involves finalizing analytical work and data evaluation, as well as final project reporting. This Third Quarterly Technical Progress Report principally summarizes the results from the benchscale testing with the second coal (Pittsburgh No. 8 Seam Coal), which occurred in April through June, 1993. It also contains preliminary economic evaluations that will go into the Final Report, as well as the plan for the final reporting task.

  5. Change in power output across a high-repetition set of bench throws and jump squats in highly trained athletes.

    Science.gov (United States)

    Baker, Daniel G; Newton, Robert U

    2007-11-01

    Athletes experienced in maximal-power and power-endurance training performed 1 set of 2 common power training exercises in an effort to determine the effects of moderately high repetitions upon power output levels throughout the set. Twenty-four and 15 athletes, respectively, performed a set of 10 repetitions in both the bench throw (BT P60) and jump squat exercise (JS P60) with a resistance of 60 kg. For both exercises, power output was highest on either the second (JS P60) or the third repetition (BT P60) and was then maintained until the fifth repetition. Significant declines in power output occurred from the sixth repetition onwards until the 10th repetition (11.2% for BT P60 and 5% for JS P60 by the 10th repetition). These findings suggest that athletes attempting to increase maximal power limit their repetitions to 2 to 5 when using resistances of 35 to 45% 1RM in these exercises.

  6. Differential impact of flow and mouth leak on oropharyngeal humidification during high-flow nasal cannula: a neonatal bench study.

    Science.gov (United States)

    Ullrich, Tim Leon; Czernik, Christoph; Bührer, Christoph; Schmalisch, Gerd; Fischer, Hendrik Stefan

    2018-03-09

    Heated humidification is paramount during neonatal high-flow nasal cannula (HFNC) therapy. However, there is little knowledge about the influence of flow rate and mouth leak on oropharyngeal humidification and temperature. The effect of the Optiflow HFNC on oropharyngeal gas conditioning was investigated at flow rates of 4, 6 and 8 L min -1 with and without mouth leak in a bench model simulating physiological oropharyngeal air conditions during spontaneous breathing. Temperature and absolute humidity (AH) were measured using a digital thermo-hygrosensor. Without mouth leak, oropharyngeal temperature and AH increased significantly with increasing flow (P < 0.001). Mouth leak did not affect this increase up to 6 L min -1 , but at 8 L min -1 , temperature and AH plateaued, and the effect of mouth leak became statistically significant (P < 0.001). Mouth leak during HFNC had a negative impact on oropharyngeal gas conditioning when high flows were applied. However, temperature and AH always remained clinically acceptable.

  7. Evaluation of ventilators used during transport of critically ill patients: a bench study.

    Science.gov (United States)

    Boussen, Salah; Gainnier, Marc; Michelet, Pierre

    2013-11-01

    To evaluate the most recent transport ventilators' operational performance regarding volume delivery in controlled mode, trigger function, and the quality of pressurization in pressure support mode. Eight recent transport ventilators were included in a bench study in order to evaluate their accuracy to deliver a set tidal volume under normal resistance and compliance conditions, ARDS conditions, and obstructive conditions. The performance of the triggering system was assessed by the measure of the decrease in pressure and the time delay required to open the inspiratory valve. The quality of pressurization was obtained by computing the integral of the pressure-time curve for the first 300 ms and 500 ms after the onset of inspiration. For the targeted tidal volumes of 300, 500, and 800 mL the errors ranged from -3% to 48%, -7% to 18%, and -5% to 25% in the normal conditions, -4% to 27%, -2% to 35%, and -3% to 35% in the ARDS conditions, and -4% to 53%, -6% to 30%, and -30% to 28% in the obstructive conditions. In pressure support mode the pressure drop range was 0.4-1.7 cm H2O, the trigger delay range was 68-198 ms, and the pressurization performance (percent of ideal pressurization, as measured by pressure-time product at 300 ms and 500 ms) ranges were -9% to 44% at 300 ms and 6%-66% at 500 ms (P ventilators. The most recent turbine ventilators outperformed the pneumatic ventilators. The best performers among the turbine ventilators proved comparable to modern ICU ventilators.

  8. Hydropyrolysis of sugar cane bagasse: effect of sample configuration on bio-oil yields and structures from two bench-scale reactors

    Energy Technology Data Exchange (ETDEWEB)

    Pindoria, R.V.; Chatzakis, I.N.; Lim, J.-Y.; Herod, A.A.; Dugwell, D.R.; Kandiyoti, R. [Imperial College of Science, Technology and Medicine, London (United Kingdom). Dept. of Chemical Engineering and Chemical Technology

    1999-01-01

    A wire-mesh reactor has been used as base-case in the study of product yields and structures from the pyrolysis and hydropyrolysis of a sample of sugar cane bagasse in a fixed bed `hot-rod` reactor. Results from the two reactors have been compared to determine how best to assess bench-scale data which might be used for eventual process development. Experiments have been carried out at 600{degree}C at pressures up to 70 bar. Structural features of the bio-oils have been examined by size exclusion chromatography and FT-infrared spectroscopy. In both reactors the effect of increasing pressure was to reduce the bio-oil and total volatile yields: hydropyrolysis bio-oil yields were marginally higher than pyrolysis yields under equivalent operating conditions. The data indicate that about one-third of the original biomass may be converted to oil by direct pyrolysis. 33 refs., 10 figs.

  9. Use of Strain Measurements from Acoustic Bench Tests of the Battleship Flowliner Test Articles To Link Analytical Model Results to In-Service Resonant Response

    Science.gov (United States)

    Frady, Greg; Smaolloey, Kurt; LaVerde, Bruce; Bishop, Jim

    2004-01-01

    The paper will discuss practical and analytical findings of a test program conducted to assist engineers in determining which analytical strain fields are most appropriate to describe the crack initiating and crack propagating stresses in thin walled cylindrical hardware that serves as part of the Space Shuttle Main Engine's fuel system. In service the hardware is excited by fluctuating dynamic pressures in a cryogenic fuel that arise from turbulent flow/pump cavitation. A bench test using a simplified system was conducted using acoustic energy in air to excite the test articles. Strain measurements were used to reveal response characteristics of two Flowliner test articles that are assembled as a pair when installed in the engine feed system.

  10. Bench-scale study of the effect of phosphate on an aerobic iron oxidation plant for mine water treatment.

    Science.gov (United States)

    Tischler, Judith S; Wiacek, Claudia; Janneck, Eberhard; Schlömann, Michael

    2014-01-01

    At the opencast pit Nochten acidic iron- and sulfate-rich mine waters are treated biotechnologically in a mine-water treatment plant by microbial iron oxidation. Due to the low phosphate concentration in such waters the treatment plant was simulated in bench-scale to investigate the influence of addition of potassium dihydrogen phosphate on chemical and biological parameters of the mine-water treatment. As a result of the phosphate addition the number of cells increased, which resulted in an increase of the iron oxidation rate in the reactor with phosphate addition by a factor of 1.7 compared to a reference approach without phosphate addition. Terminal restriction fragment length polymorphism (T-RFLP) analysis during the cultivation revealed a shift of the microbial community depending on the phosphate addition. While almost exclusively iron-oxidizing bacteria related to "Ferrovum" sp. were detected with phosphate addition, the microbial community was more diverse without phosphate addition. In the latter case, iron-oxidizing bacteria ("Ferrovum" sp., Acidithiobacillus spp.) as well as non-iron-oxidizing bacteria (Acidiphilium sp.) were identified. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. Soluble Microbial Product Characterization of Biofilm Formation in Bench-Scale

    KAUST Repository

    Mines, Paul

    2012-12-01

    The biological process known as activated sludge (AS) in conjunction with membrane separation technology for the treatment of wastewater has been employed for over four decades. While, membrane biological reactors (MBR) are now widely employed, the phenomenon of membrane fouling is still the most significant factor leading to performance decline of MBRs. Although much research has been done on the subject of MBR fouling over the past two decades, many questions remain unanswered, and consensus within the scientific community is rare. However, research has led to one system parameter generally being regarded as a contributor to membrane fouling, extracellular polymeric compounds (EPS). EPS, and more specifically, the soluble fraction of EPS known as soluble microbial products (SMP), must be further investigated in order to better understand membrane fouling. The biological activity and performance of the MBR is affected by myriad operational parameters, which in turn affects the SMP generated. A commonly varied operational parameter is, depending on the specific treatment needs of a MBR, the sludge retention time (SRT). This study aims to characterize the SMP in three bench-scale MBRs as the SRT is gradually lowered. By studying how the SMP change as the operation of the system is altered, greater understanding of how SMP are related to fouling can be achieved. At the onset of the study, a steady state was established in the system with a SRT of 20 days. Upon stabilization of a 20 day SRT, the system was gradually transitioned to a five and a half day SRT, in stepwise adjustments. Initially, both the trans-membrane pressure (TMP) and the SMP concentrations were at relatively low values, indicating the presence of minimal amounts of biofilm on the membrane surfaces. As the system was altered and more activated sludge was wasted from the reactors, the SRT inherently decreased. As the lower SRT was transitioned and established, the data from TMP measurements, as well

  12. Organisation of maintenance of health semi-portable detectors. IPAB-CFA-CABP control bench; Organisation de la maintenance des detecteurs semi-portatifs de sante. Banc de controle des IPAB-CFA-CABP

    Energy Technology Data Exchange (ETDEWEB)

    De Choudens, H.; Rage, P. [Commissariat a l' energie atomique et aux energies alternatives - CEA, Centre d' Etudes Nucleaires de Grenoble (France)

    1963-07-01

    As the number of electronic semi-portable health measurement devices is (was) increasing, it appears (appeared) important to organise their maintenance. In this report, the authors describe the implemented organisation. They indicate how a device is identified, which are the performed tests, and discuss results which have been obtained during the first year of implementation of this maintenance organisation. Then, they present the control bench, its operation (supply, measurement circuits), its use (control process for different devices, performed measurements and controls)

  13. Bench-top endomicroscope for visualization and imaging of nuclei using ultraviolet autofluorescence

    Science.gov (United States)

    Lin, Bevin

    The long range goal of this research was to develop autofluorescence technology and instrumentation for transition towards an in vivo endomicroscopy imaging system. This approach would provide resolution sufficient to image nuclei for real-time categorization of normal and abnormal tissue implicative of disease progression. Esophageal adenocarcinoma was the chosen model to develop this diagnostic imaging system because the heterogeneous and multifocal nature of this disease makes early diagnosis extremely challenging during the window of time when the prognosis for survival is high. The asymptomatic character of this disease generally presents at a malignant stage when removal of the esophagus has become the standard treatment. The traditional gold standard of histologic diagnosis suffers from a slow turn-around-time from tissue removal to microscopic observation, compounded by error in random biopsy sampling and tissue-processing artifacts, in addition to significant variation in pathologist diagnosis. Optical biopsy has thus been developed to alleviate the problems associated with current standard video endoscopy and histopathology. Following tremendous research in the realm of optical biopsy, some traction has been gained using confocal endomicroscopy. However, current confocal methods require contrast agents and optical sectioning in order to provide images at a cellular level. We have developed a minimally invasive imaging system using autofluorescence that highlights the short photon penetration depth of ultraviolet excitation. This approach provides cellular level resolution with a clinically relevant field of view without requiring contrast agents or optical sectioning. Optical histopathology has been demonstrated using unprocessed ex vivo human gastrointestinal tissues providing diagnostic assessment in real-time, a function imperative for improved patient care and quality of life. This robust bench-top prototype endomicroscopy system is capable of rapid

  14. Development and experimental validation of a thermoelectric test bench for laboratory lessons

    Directory of Open Access Journals (Sweden)

    Antonio Rodríguez

    2013-12-01

    Full Text Available The refrigeration process reduces the temperature of a space or a given volume while the power generation process employs a source of thermal energy to generate electrical power. Because of the importance of these two processes, training of engineers in this area is of great interest. In engineering courses it is normally studied the vapor compression and absorption refrigeration, and power generation systems such as gas turbine and steam turbine. Another type of cooling and generation less studied within the engineering curriculum, having a great interest, it is cooling and thermal generation based on Peltier and Seebeck effects. The theoretical concepts are useful, but students have difficulties understanding the physical meaning of their possible applications. Providing students with tools to test and apply the theory in real applications, will lead to a better understanding of the subject. Engineers must have strong theoretical, computational and also experimental skills. A prototype test bench has been built and experimentally validated to perform practical lessons of thermoelectric generation and refrigeration. Using this prototype students learn the most effective way of cooling systems and thermal power generation as well as basic concepts associated with thermoelectricity. It has been proven that students learn the process of data acquisition, and the technology used in thermoelectric devices. These practical lessons are implemented for a 60 people group of students in the development of subject of Thermodynamic including in the Degree in Engineering in Industrial Technologies of Public University of Navarra. Normal 0 21 false false false ES X-NONE X-NONE Normal 0 21 false false false ES X-NONE X-NONE Bench tests of simple, handy ventilators for pandemics: performance, autonomy, and ergonomy.

    Science.gov (United States)

    L'Her, Erwan; Roy, Annie

    2011-06-01

    It has been pointed out that in the wake of a virulent flu strain, patients with survivable illness will die from lack of resources unless more ventilators are made available. Numerous disaster-type ventilators are available, but few evaluations have been performed. To compare simple, lightweight, and handy ventilators that could be used in the initial care of patients with respiratory distress. We bench-tested 4 volume-cycled ventilators (Carevent ALS, EPV100, Pneupac VR1, and Medumat Easy) and 2 pressure-cycled ventilators (Oxylator EMX and VAR-Plus). We studied their general physical characteristics, sonometry, gas consumption, technical performance, ergonomy, and user-friendliness. With a test lung we assessed performance at F(IO(2)) of 0.50 and 1.0, set compliance of 30, 70, and 120 mL/cm H(2)O, and set resistance of 5, 10, and 20 cm H(2)O/L/s. To study user-friendliness and ergonomy we conducted, in randomized order, 7 or 8 objective, quantitative tests and 2 subjective tests. Compliance and resistance strongly affected tidal volume with the pressure-cycled ventilators (from 418 ± 49 mL to 1,377 ± 444 mL with the VAR-Plus, at the lowest pressure level), whereas the volume-cycled ventilators provided a consistent tidal volume in the face of changing test lung characteristics. We are concerned that the pressure-cycled ventilators did not provide a consistent tidal volume, and under certain conditions the volume delivered would be unsafe (too large or too small). Most of the volume-cycled ventilators proved to be technically efficient and reliable. Their reliability, portability, and ease of use could make them valuable in natural disasters and mass-casualty events.

  15. Characterization of the acoustic-vortex shedding coupling inside a validation bench; Caracterisation du couplage acoustique. Detachement tourbillonnaire a l'interieur d'un montage de validation

    Energy Technology Data Exchange (ETDEWEB)

    Dupays, J.; Prevost, M.; Tarrin, P.; Vuillot, F.

    1998-07-01

    Two campaigns of tests based on a small bench test installation, naturally instable and using various propellants with or without calibrated particles, were carried out at the Onera. The numerous pressure measurements performed along the engine have permitted to explain the wave system that takes place inside the combustion chamber as the sum of two acoustic waves and a convective wave with the same frequency, and linked with the evolution of vortices. This result shows that a coupling exists between the acoustic properties of the chamber and the vortex shedding whatever is the propellant used. (J.S.)

  16. Comparison of Portable and Bench-Top Spectrometers for Mid-Infrared Diffuse Reflectance Measurements of Soils

    Directory of Open Access Journals (Sweden)

    Christopher Hutengs

    2018-03-01

    Full Text Available Mid-infrared (MIR spectroscopy has received widespread interest as a method to complement traditional soil analysis. Recently available portable MIR spectrometers additionally offer potential for on-site applications, given sufficient spectral data quality. We therefore tested the performance of the Agilent 4300 Handheld FTIR (DRIFT spectra in comparison to a Bruker Tensor 27 bench-top instrument in terms of (i spectral quality and measurement noise quantified by wavelet analysis; (ii accuracy of partial least squares (PLS calibrations for soil organic carbon (SOC, total nitrogen (N, pH, clay and sand content with a repeated cross-validation analysis; and (iii key spectral regions for these soil properties identified with a Monte Carlo spectral variable selection approach. Measurements and multivariate calibrations with the handheld device were as good as or slightly better than Bruker equipped with a DRIFT accessory, but not as accurate as with directional hemispherical reflectance (DHR data collected with an integrating sphere. Variations in noise did not markedly affect the accuracy of multivariate PLS calibrations. Identified key spectral regions for PLS calibrations provided a good match between Agilent and Bruker DHR data, especially for SOC and N. Our findings suggest that portable FTIR instruments are a viable alternative for MIR measurements in the laboratory and offer great potential for on-site applications.

  17. Facility Bench of Stationary Engines for Study of Emissions (E65-PO) CIEMAT; Instalacion Banco de Motores Estacionarios para Estudio de Emisiones (E65-PO) CIEMAT

    Energy Technology Data Exchange (ETDEWEB)

    Rojas Garcia, E; Rodriguez Maroto, J J

    2007-07-01

    The Project of Technology of Aerosols in Generation of Energy, of the Department of Fossil Fuels of the CIEMAT, began in the year 2004, a research activity line, based on the study of the emissions coming from internal combustion engines, particularly of Diesel technology. Activity was continued by the Polluting Emissions Group of the Department of Environment, when becoming the original Project in this Group. From the concession to the Group, of the project GR/AMB/0119/2004 Evaluation of the Emissions of Biodiesel supported by the Autonomous Community of Madrid together with the European Regional Development Fund (ERDF), this activity was encourage, with the design, assembly and to get ready of the facility Bench of stationary engines for study of emissions, located in the building 65 at CIEMAT, Madrid. The present report constitutes a detailed technical description of each one of the elements that the installation Bench of stationary engines for study of emissions it integrated within the framework of the referred project (GR/AMB/0119/2004) and whose capacity includes studies of the effects of the engine, fuel, operation conditions, and methodology of sampling and measurement of emissions (gases and particles). The fundamental parts of facility describes in the present report are: engine test cell (cabin of sound insulation , ventilation and refrigeration system, anti vibrations mounting, engine, dynamometric brake), lines of preconditioning of particles and gases emissions (exhaust line, primary and secondary dilution lines, gases cleaning system...), other general parts of facility (sampling and measurement station, service lines...). The present report not only reflects the characteristics of the systems involved, but rather also in certain cases specified the procedure and reason for their choice. (Author) 10 refs.

  18. Portable test bench for the studies concerning ion sources and ion beam extraction and focusing systems; Banco de pruebas portatil para el estudio de fuentes de iones y de la extraccion y enfoque del haz de iones

    Energy Technology Data Exchange (ETDEWEB)

    Cordero Lopez, F

    1961-07-01

    A portable test bench is described, which was designed to check ion sources, ion beam extraction and focusing systems before its use in a 600 KeV Cockcroft-Walton accelerator. The vacuum possibilities of the system are specially analyzed in connection with its particular use. The whole can be considered as a portable accelerator of low energy (50 keV). (Author)

  19. Design studies for a tracking upgrade of the Crystal Barrel experiment at ELSA and installation of tracking test bench

    International Nuclear Information System (INIS)

    Winnebeck, Alexander

    2009-01-01

    Ever since mankind was interested in the understanding of the universe and especially the matter in it. The fundamental building blocks of matter seem to be quarks and gluons, whose interactions are investigated in hadron physics. To study this strong interaction different experimental approaches can be used. One way is to do spectroscopy similar to atomic physics. The Crystal Barrel experiment at ELSA performs spectroscopy of nucleons to learn more about the strong interaction. A major improvement of this experimental setup will be the introducing of charged particle tracking as it is shown in this thesis. Different detector concepts are discussed concerning feasibility, material budget and especially momentum resolution. It turns out that a Time Projection Chamber (TPC) is the optimal solution. Then it is shown how a prototype TPC is tested using a newly installed tracking test bench with an electron beam, and obtained results are presented. The design of the final TPC and its integration into the Crystal Barrel experiment are discussed as well as methods to calibrate the detector. (orig.)