WorldWideScience

Sample records for bei musikern gem

  1. Gas amplification properties of GEM foils; Gasverstaerkungseigenschaften von GEM-Folien

    Energy Technology Data Exchange (ETDEWEB)

    Beck, Jeannine

    2009-01-15

    procedure were developed and a laser-measurement arrangement for the measurement of GEM surface profiles designed and tested. The Planeness of framed GEM foils was determined, whereby height differences up to 1 mm resulted. [German] Im Rahmen des Detektorkonzeptes International Linear Detector fuer das kuenftige Beschleunigerprojekt International Linear Collider, an dem Elektronen und Positronen bei Schwerpunktsenergien von 500 GeV zur Kollision gebracht werden, soll eine Zeit-Projektions-Kammer als zentrale Spurkammer eingesetzt werden. Mit der Verwendung einer derartigen Kammer als Spurdetektor ist eine dreidimensionale Rekonstruktion der Spurpunkte moeglich. Durchfliegt ein Teilchen das Gasvolumen innerhalb der Kammer, ionisiert es einzelne Gasatome und die entstandenen Elektronen bewegen sich nach der Verstaerkung in der GEM-Anordnung (engl. Gas Electron Multiplier) zur Anode, so dass eine zweidimensionale Projektion der Teilchenspur moeglich ist. Die dritte Dimension wird aus der Driftzeit der Elektronen errechnet. Die Vorteile dieses Auslesesystems bestehen darin, dass eine bessere Ortsaufloesung als mit einer Vieldraht-Proportional-Kammer erreicht wird und die rueckdriftenden Ionen stark unterdrueckt werden koennen. Ziel dieser Arbeit sind Untersuchungen fuer ein GEM-Modul, das in einem grossen TPCPrototypen genutzt werden soll. Hinsichtlich verschiedener Anforderungen gilt es unterschiedliche GEMs zu vergleichen, um eine optimale Auswahl treffen zu koennen. In einem am DESY vorhandenen kleinen Prototypen wurden Messungen zur Erfassung von GEM-beschreibenden Parametern durchgefuehrt. Die Inbetriebnahme der Test-TPC war Bestandteil dieser Arbeit. Es wurden Spuren durch eine radioaktive Quelle erzeugt, mit deren Hilfe die Gasverstaerkung bestimmt wurde. Mit dem Messaufbau wurden verschiedenartige Gasverstaerkerfolien hinsichtlich ihrer Verstaerkungseigenschaften und ihres Energieaufloesungsvermoegens verglichen und systematisch studiert. Es wurden fuenf

  2. Der Einfluss von Alitretinoin auf die Lebensqualität bei Patienten mit schwerem chronischen Handekzem: FUGETTA - Beobachtungsstudie unter Praxisbedingungen.

    Science.gov (United States)

    Augustin, Matthias; Thaçi, Diamant; Kamps, Anja

    2016-12-01

    Alitretinoin ist die einzige zugelassene Behandlung für schweres chronisches Handekzem (CHE), das refraktär gegenüber potenten topischen Corticosteroiden ist. Bei dieser Studie (FUGETTA) wurde die Wirksamkeit von leitliniengerecht angewendetem oralem Alitretinoin sowie dessen Einfluss auf die Lebensqualität (LQ) bei Patienten mit schwerem refraktärem CHE beurteilt. Multizentrische, offene, nichtinterventionelle Beobachtungsstudie, durchgeführt in Deutschland. Die Patienten wurden nach Ermessen ihres behandelnden Arztes mit Alitretinoin 10 mg oder 30 mg einmal täglich über maximal 24 Wochen behandelt. Die Wirksamkeit wurde anhand des Physician Global Assessment (PGA) und des Dermatology Life Quality Index (DLQI) bewertet. Zudem wurden unerwünschte Ereignisse (UE) erfasst. Die Studienpopulation bestand aus 658 Patienten (30 mg: n = 581; 10 mg: n = 77). Bei Beobachtungsbeginn litten die meisten Patienten (83 %) gemäß PGA an einem schweren CHE. Bei Beobachtungsende war das Handekzem bei 48 % der Patienten gemäß PGA vollständig oder fast vollständig abgeheilt (30 mg: 49 %; 10 mg: 43 %). Die mittlere Verbesserung des DLQI-Scores in Woche 24 betrug 58 % (30 mg: mittlere [SD] Veränderung gegenüber dem Ausgangswert -10,4 [8,04]) und 70 % (10 mg: mittlere [SD] Veränderung gegenüber dem Ausgangswert -10,8 [7,29]). Die Gesamtinzidenz von NW war niedrig und in den beiden Gruppen ähnlich. Alitretinoin führte zu einer schnellen, deutlichen Verbesserung der LQ bei Patienten mit schwerem CHE. © 2016 Deutsche Dermatologische Gesellschaft (DDG). Published by John Wiley & Sons Ltd.

  3. GEM: Performance and aging tests

    International Nuclear Information System (INIS)

    Cho, H.S.; Kadyk, J.; Han, S.H.; Hong, W.S.; Perez-Mendez, V.; Wenzel, W.; Pitts, K.; Martin, M.D.; Hutchins, J.B.

    1999-01-01

    Performance and aging tests have been done to characterize Gas Electron Multipliers (GEMs), including further design improvements such as a thicker GEM and a closed GEM. Since the effective GEM gain is typically smaller than the absolute GEM gain, due to trapping of avalanche electrons at the bottom GEM electrode, the authors performed field simulations and measurements for better understanding, and discuss methods to eliminate this effect. Other performance parameters of the GEMs are also presented, including absolute GEM gain, short-term and long-term gain stabilities

  4. Origins of GEMS Grains

    Science.gov (United States)

    Messenger, S.; Walker, R. M.

    2012-01-01

    Interplanetary dust particles (IDPs) collected in the Earth s stratosphere contain high abundances of submicrometer amorphous silicates known as GEMS grains. From their birth as condensates in the outflows of oxygen-rich evolved stars, processing in interstellar space, and incorporation into disks around new stars, amorphous silicates predominate in most astrophysical environments. Amorphous silicates were a major building block of our Solar System and are prominent in infrared spectra of comets. Anhydrous interplanetary dust particles (IDPs) thought to derive from comets contain abundant amorphous silicates known as GEMS (glass with embedded metal and sulfides) grains. GEMS grains have been proposed to be isotopically and chemically homogenized interstellar amorphous silicate dust. We evaluated this hypothesis through coordinated chemical and isotopic analyses of GEMS grains in a suite of IDPs to constrain their origins. GEMS grains show order of magnitude variations in Mg, Fe, Ca, and S abundances. GEMS grains do not match the average element abundances inferred for ISM dust containing on average, too little Mg, Fe, and Ca, and too much S. GEMS grains have complementary compositions to the crystalline components in IDPs suggesting that they formed from the same reservoir. We did not observe any unequivocal microstructural or chemical evidence that GEMS grains experienced prolonged exposure to radiation. We identified four GEMS grains having O isotopic compositions that point to origins in red giant branch or asymptotic giant branch stars and supernovae. Based on their O isotopic compositions, we estimate that 1-6% of GEMS grains are surviving circumstellar grains. The remaining 94-99% of GEMS grains have O isotopic compositions that are indistinguishable from terrestrial materials and carbonaceous chondrites. These isotopically solar GEMS grains either formed in the Solar System or were completely homogenized in the interstellar medium (ISM). However, the

  5. Not Your Ordinary GEM

    Science.gov (United States)

    2001-01-01

    Through Small Business Innovation Research (SBIR) funding from NASA's Stennis Space Center, Geophex devised a new design for broadband electromagnetic sensors. Geophex developed a patented sensing technology, capable not only of coastal monitoring, but also a variety of other functions, including environmental pollution characterization, groundwater contamination detection, archaeological study, and mineral detection. The new technology is offered in several of the company's products the GEM-2, GEM-2A, and the GEM-3. The Geophex products consist of two primary electromagnetic coils, which are stimulated by alternating currents that generate a magnetic field in the object targeted for investigation. GEM-2 is a handheld, lightweight, programmable, digital device. GEM-2A is an airborne version of the sensor. Suspended from a helicopter, the GEM-2A is used to search for mineral deposits and to survey large tracts of land. The GEM-3 is capable of detecting buried landmines and other active munitions. GEM-3 identifies landmines by their brand names. Because each landmine has its own unique electromagnetic response to the broad frequency band emitted by the GEM-3, bomb identification and disposal strategies are made easier.

  6. Development of a glass GEM

    International Nuclear Information System (INIS)

    Takahashi, Hiroyuki; Mitsuya, Yuki; Fujiwara, Takeshi; Fushie, Takashi

    2013-01-01

    Gas electron multipliers (GEMs) apply the concept of gas amplification inside many tiny holes, realizing robust and high-gain proportional counters. However, the polyimide substrate of GEMs prevents them from being used in sealed detector applications. We have fabricated and tested glass GEMs (G-GEMs) with substrates made of photosensitive glass material from the Hoya Corporation. We fabricated G-GEMs with several different hole diameters and thicknesses and successfully operated test G-GEMs with a 100×100 mm 2 effective area. The uniformity of our G-GEMs was good, and the energy resolution for 5.9 keV X-rays was 18.8% under uniform irradiation of the entire effective area. A gas gain by the G-GEMs of up to 6700 was confirmed with a gas mixture of Ar (70%)+CH 4 (30%). X-ray imaging using the charge division readout method was demonstrated

  7. Gas Electron Multipliers: Development of large area GEMs and spherical GEMs

    CERN Document Server

    Duarte Pinto, Serge; Brock, Ian

    2011-01-01

    Gaseous radiation detectors have been a crucial part of high-energy physics instrumentation since the 1960s, when the first multiwire proportional counters were built. In the 1990s the first micropattern gas detectors (MPGDs) saw the light; with sub-millimeter feature sizes these novel detectors were faster and more accurate than their predecessors. The gas electron multiplier (GEM) is one of the most successful of these technologies. It is a charge multiplication structure made from a copper clad polymer foil, pierced with a regular and dense pattern of holes. I will describe the properties and the application of GEMs and GEM detectors, and the research and development I have done on this technology. Two of the main objectives were the development of large area GEMs (~m^2) for particle physics experiments and GEMs with a spherical shape for x-ray or neutron diffraction detectors. Both have been realized, and the new techniques involved are finding their way to applications in research and industry.

  8. Gas electron multipliers. Development of large area GEMS and spherical GEMS

    Energy Technology Data Exchange (ETDEWEB)

    Pinto, Serge Duarte

    2011-08-15

    Gaseous radiation detectors have been a crucial part of high-energy physics instrumentation since the 1960s, when the first multiwire proportional counters were built. In the 1990s the first micropattern gas detectors (MPGDS) saw the light; with sub-millimeter feature sizes these novel detectors were faster and more accurate than their predecessors. The gas electron multiplier (GEM) is one of the most successful of these technologies. It is a charge multiplication structure made from a copper clad polymer foil, pierced with a regular and dense pattern of holes. I describe the properties and the application of GEMs and GEM. detectors, and the research and development I have done on this technology. Two of the main objectives were the development of large area GEMs ({proportional_to}m{sup 2}) for particle physics experiments and GEMs with a spherical shape for X-ray or neutron diffraction detectors. Both have been realized, and the new techniques involved are finding their way to applications in research and industry. (orig.)

  9. Gas electron multipliers: Development of large area GEMS and spherical GEMS

    International Nuclear Information System (INIS)

    Pinto, Serge Duarte

    2011-08-01

    Gaseous radiation detectors have been a crucial part of high-energy physics instrumentation since the 1960s, when the first multiwire proportional counters were built. In the 1990s the first micropattern gas detectors (MPGDS) saw the light; with sub-millimeter feature sizes these novel detectors were faster and more accurate than their predecessors. The gas electron multiplier (GEM) is one of the most successful of these technologies. It is a charge multiplication structure made from a copper clad polymer foil, pierced with a regular and dense pattern of holes. I describe the properties and the application of GEMs and GEM. detectors, and the research and development I have done on this technology. Two of the main objectives were the development of large area GEMs (∝m 2 ) for particle physics experiments and GEMs with a spherical shape for X-ray or neutron diffraction detectors. Both have been realized, and the new techniques involved are finding their way to applications in research and industry. (orig.)

  10. [Osteopathie bei gastroösophagealem Reflux mit Hiatushernie: Ein Fallbericht gemäß der CARE-Leitlinie].

    Science.gov (United States)

    Rotter, Gabriele; Brinkhaus, Benno

    2017-01-01

    Hintergrund: Das Vorhandensein einer Hiatushernie kann das Auftreten einer gastroösophagealen Refluxerkrankung (GERD) als Komplikation bedingen. Konventionelle medizinische Therapiemaßnahmen können zu unerwünschten Ereignissen und Rezidiven führen. Bisher sind die Effekte von osteopathischen Behandlungen bei Hiatushernie und GERD nicht bekannt. Fallbericht: Eine 59-jährige Patientin mit endoskopisch diagnostizierter chronischer Gastritis, GERD und Hiatushernie beklagte einen persistierenden gastroösophagealen Reflux trotz konventionell-medizinischer konservativer Therapie. Die osteopathische Diagnostik ergab eine funktionelle Störung im Bereich des Magens und der Kardia mit einer Beteiligung zugehöriger Reflexzonen. Nach einer osteopathischen Behandlung als individuelle, befundorientierte Therapie ließen die Beschwerden erheblich nach. Die Hiatushernie war nach einer dieser Behandlung endoskopisch nicht mehr nachweisbar. Schlussfolgerungen: Dieser Fallbericht schildert die Symptomreduktion einer GERD nach osteopathischer Behandlung. In der endoskopischen Folgeuntersuchung fand sich die initial diagnostizierte Hiatushernie nicht mehr, diese Befund änderung könnte jedoch auf die unterschiedlichen Untersucher zurückgeführt werden. Prospektive kontrollierte klinische Studien sind notwendig, um den Stellenwert von osteopathischen Behandlungen bei GERD mit Hiatushernie zu untersuchen. © 2017 The Author(s). Published by S. Karger GmbH, Freiburg.

  11. Effekt einer ad libitum verzehrten fettreduzierten Kost, reich an Obst, Gemüse und Milchprodukten auf den Blutdruck bei Borderline-Hypertonikern

    Science.gov (United States)

    Möseneder, Jutta M.

    2002-01-01

    In der randomisierten, multizentrischen DASH-Studie (Dietary Approaches to Stop Hy-pertension), die unter kontrollierten Bedingungen stattfand, führte eine fettreduzierte Mischkost, reich an Obst, Gemüse und Milchprodukten, bei Borderline-Hypertonikern zu einer signifikanten Blutdrucksenkung. Während der Studienphase wurden Körpermasse, Natrium-Aufnahme sowie Alkoholzufuhr aufgrund der bekannten Einflussnahme auf den Blutdruck konstant gehalten. In der eigenen Pilot-Studie sollte untersucht werden, ob das Ergebnis der DASH-Studie (i) mit deutschen Hypertonikern und (ii) unter habituellen Ernährungs- und Lebensbedingungen mit regelmäßig durchgeführter Ernährungsberatung und ad libitum Verzehr anstelle des streng kontrollierten Studienansatzes bestätigt werden kann. Eine Konstanz der Körpermasse, der Natrium-Urinausscheidung (unter diesem Studienansatz valider als die Aufnahme) und des Alkoholkonsums wurde vorausgesetzt. Die Studienpopulation setzte sich aus 53 übergewichtigen Probanden mit einer nicht medikamentös therapierten Borderline-Hypertonie und ohne Stoffwechselerkrankungen zusammen. Die Studienteilnehmer wurden randomisiert entweder der Idealgruppe mit einer fettarmen Kost reich an Milchprodukten, Obst und Gemüse (ähnlich der DASH-Idealgruppe) oder der Kontrollgruppe mit habitueller Ernährungsweise zugeteilt. Über einen Zeitraum von fünf Wochen wurde den Probanden etwa 50% ihres täglichen Lebensmittelbedarfes entsprechend ihrer Gruppenzugehörigkeit kostenfrei zur Verfügung gestellt. Gelegenheitsblutdruckmessungen und 24h-Blutdruckmessungen, Ernährungs- und Aktivitätsprotokolle, Blut- und Urinproben sowie anthropometrische Messungen wurden vor, während und fünf Wochen nach der Interventionsphase durchgeführt. Die Ergebnisse zeigen, dass in der Idealgruppe keine signifikante Blutdrucksenkung beobachtet werden konnte. Dies lässt sich durch die Tatsache erklären, dass die Lebens-mittel- und Nährstoffaufnahme der deutschen

  12. Graphics gems

    CERN Document Server

    Glassner, Andrew S

    1993-01-01

    ""The GRAPHICS GEMS Series"" was started in 1990 by Andrew Glassner. The vision and purpose of the Series was - and still is - to provide tips, techniques, and algorithms for graphics programmers. All of the gems are written by programmers who work in the field and are motivated by a common desire to share interesting ideas and tools with their colleagues. Each volume provides a new set of innovative solutions to a variety of programming problems.

  13. Graphics Gems III IBM version

    CERN Document Server

    Kirk, David

    1994-01-01

    This sequel to Graphics Gems (Academic Press, 1990), and Graphics Gems II (Academic Press, 1991) is a practical collection of computer graphics programming tools and techniques. Graphics Gems III contains a larger percentage of gems related to modeling and rendering, particularly lighting and shading. This new edition also covers image processing, numerical and programming techniques, modeling and transformations, 2D and 3D geometry and algorithms,ray tracing and radiosity, rendering, and more clever new tools and tricks for graphics programming. Volume III also includes a

  14. Graphics gems V (Macintosh version)

    CERN Document Server

    Paeth, Alan W

    1995-01-01

    Graphics Gems V is the newest volume in The Graphics Gems Series. It is intended to provide the graphics community with a set of practical tools for implementing new ideas and techniques, and to offer working solutions to real programming problems. These tools are written by a wide variety of graphics programmers from industry, academia, and research. The books in the series have become essential, time-saving tools for many programmers.Latest collection of graphics tips in The Graphics Gems Series written by the leading programmers in the field.Contains over 50 new gems displaying some of t

  15. Mexican gems as thermoluminescent dosimeters

    International Nuclear Information System (INIS)

    Azorin N, J.

    1979-01-01

    The possibility of using naturally ocurring mexican gems as thermoluminescent dosimeters (TLD) was investigated. Twelve types of gems were irradiated with X and gamma rays in order to determinate their dosimetric properties. Three of these gems showed favorable thermoluminescent characteristics compared with commercial thermoluminescent dosimeters. The plots of their thermoluminescent response as a function of gamma dose are straight lines on full log paper in the dose range 10 -2 to 10 2 Gy. The energy dependence is very strong to low energies of the radiation. Their fading was found to be about 5%/yr. and they may be annealed as reused without loss in sensitivity. Therefore, these gems can be used as X and gamma radiation dosimeters. (author)

  16. Gas amplification properties of GEM foils

    International Nuclear Information System (INIS)

    Beck, Jeannine

    2009-01-01

    In the framework of the detector concept International Linear Detector for the future accelerator project International Linear Collider, in which electrons and positrons at c. m. energies of 500 GeV are brought to collision, a time projection chamber shall be applied as central track detector. By the application of such a chamber as track detector a three-dimensional reconstruction of the track points is possible. If a particle passes the gas volume within the chamber it ionizises single gas atoms and the arising electrons move after the amplification in the GEM arrangement to the anode, so that a two-dimensional projection of the particle track is possible. The third dimension is calculated from the drift time of the electrons. The advances of this readout system consist therein that a better position resolution than by a multiwire proportional chamber is reached and the back-drifting ions can be strongly suppressed. Aim of this thesis are studies for a GEM module, which shall be used in a large TPC prototype. Concerning different requirements it is valid to compare different GEMs in order to can meet an optimal choice. In a small prototype present at DESY measurements for the acquisition of GEM-describing parameters were performed. The taking into operation of the test TPC was part of this thesis. Tracks were generated by a radioactive source, by means of which the gas amplification was determined. With the measurement arrangement gas-amplifier foils of different kind were compared in view of their amplification properties and their energy resolution power and systematically studied. Five different GEM performances were studied in the test TPC. These foils differ in their geometrical classification parameters, the fabrication process, or the materials. The GEMs produced at CERN possess in comparison with GEMs of the Japanese firm SciEnergy and a GEM of the US-American firm Tech-Etch the best amplification and resolution properties. Furthermore a new GEM framing

  17. Development of a Diehard GEM using PTFE insulator substrate

    International Nuclear Information System (INIS)

    Wakabayashi, M; Tamagawa, T; Takeuchi, Y; Aoki, K; Taketani, A; Komiya, K; Hamagaki, H

    2014-01-01

    We have developed the gas electron multiplier (GEM) using polytetrafluoroethylene (PTFE) insulator substrate (PTFE-GEM). Carbonization on insulator layer by discharges shorts the GEM electrodes, causing permanent breakdown. Since PTFE is hard to be carbonized against arc discharges, PTFE-GEM is expected to be robust against breakdown. Gains as high as 2.6 × 10 4 were achieved with PTFE-GEM (50 μm thick) in Ar/CO 2 = 70%/30% gas mixture at V GEM = 730 V. PTFE-GEM never showed a permanent breakdown even after suffering more than 40000 times discharges during the experiment. The result demonstrates that PTFE-GEM is really robust against discharges. We conclude that PTFE is an excellent insulator material for the GEM productions

  18. Development of a Diehard GEM using PTFE insulator substrate

    OpenAIRE

    Wakabayashi, M.; Komiya, K.; Tamagawa, T.; Takeuchi, Y.; Aoki, K.; Taketani, A.; Hamagaki, H.

    2014-01-01

    We have developed the gas electron multiplier (GEM) using polytetrafluoroethylene (PTFE) insulator substrate (PTFE-GEM). Carbonization on insulator layer by discharges shorts the GEM electrodes, causing permanent breakdown. Since PTFE is hard to be carbonized against arc discharges, PTFE-GEM is expected to be robust against breakdown. Gains as high as 2.6x10^4 were achieved with PTFE-GEM (50 um thick) in Ar/CO2 = 70%/30% gas mixture at V_GEM = 730V. PTFE-GEM never showed a permanent breakdown...

  19. Progress on large area GEMs (VCI 2010)

    CERN Document Server

    Villa, Marco; Alfonsi, Matteo; Brock, Ian; Croci, Gabriele; David, Eric; de Oliveira, Rui; Ropelewski, Leszek; Taureg, Hans; van Stenis, Miranda

    2011-01-01

    The Gas Electron Multiplier (GEM) manufacturing technique has recently evolved to allow the production of large area GEMs. A novel approach based on single mask photolithography eliminates the mask alignment issue, which limits the dimensions in the traditional double mask process. Moreover, a splicing technique overcomes the limited width of the raw material. Stretching and handling issues in large area GEMs have also been addressed. Using the new improvements it was possible to build a prototype triple-GEM detector of ~ 2000 cm2 active area, aimed at an application for the TOTEM T1 upgrade. Further refinements of the single mask technique give great control over the shape of the GEM holes and the size of the rims, which can be tuned as needed. In this framework, simulation studies can help to understand the GEM behavior depending on the hole shape.

  20. Performance of gas electron multiplier (GEM) detector

    International Nuclear Information System (INIS)

    Han, S. H.; Moon, B. S.; Kim, Y. K.; Chung, C. E.; Kang, H. D.; Cho, H. S.

    2002-01-01

    We have investigated in detail the operating properties of Gas Electron Multiplier (GEM) detectors with a double conical and a cylindrical structure in a wide range of external fields and GEM voltages. With the double conical GEM, the gain gradually increased with time by 10%; whereas this surface charging was eliminated with the cylindrical GEM. Effective gains above 1000 were easily observed over a wide range of collection field strengths in a gas mixture of Ar/CO 2 (70/30). The transparency and electron collection efficiency were found to depend on the ratio of external field and the applied GEM voltage; the mutual influence of both drift and collection fields was found to be trivial

  1. GEM Building Taxonomy (Version 2.0)

    Science.gov (United States)

    Brzev, S.; Scawthorn, C.; Charleson, A.W.; Allen, L.; Greene, M.; Jaiswal, Kishor; Silva, V.

    2013-01-01

    This report documents the development and applications of the Building Taxonomy for the Global Earthquake Model (GEM). The purpose of the GEM Building Taxonomy is to describe and classify buildings in a uniform manner as a key step towards assessing their seismic risk, Criteria for development of the GEM Building Taxonomy were that the Taxonomy be relevant to seismic performance of different construction types; be comprehensive yet simple; be collapsible; adhere to principles that are familiar to the range of users; and ultimately be extensible to non-buildings and other hazards. The taxonomy was developed in conjunction with other GEM researchers and builds on the knowledge base from other taxonomies, including the EERI and IAEE World Housing Encyclopedia, PAGER-STR, and HAZUS. The taxonomy is organized as a series of expandable tables, which contain information pertaining to various building attributes. Each attribute describes a specific characteristic of an individual building or a class of buildings that could potentially affect their seismic performance. The following 13 attributes have been included in the GEM Building Taxonomy Version 2.0 (v2.0): 1.) direction, 2.)material of the lateral load-resisting system, 3.) lateral load-resisting system, 4.) height, 5.) date of construction of retrofit, 6.) occupancy, 7.) building position within a block, 8.) shape of the building plan, 9.) structural irregularity, 10.) exterior walls, 11.) roof, 12.) floor, 13.) foundation system. The report illustrates the pratical use of the GEM Building Taxonomy by discussing example case studies, in which the building-specific characteristics are mapped directly using GEM taxonomic attributes and the corresponding taxonomic string is constructed for that building, with "/" slash marks separating attributes. For example, for the building shown to the right, the GEM Taxonomy string is: DX1/MUR+CLBRS+MOCL2/LWAL3/

  2. GEM Technical Design Report

    Energy Technology Data Exchange (ETDEWEB)

    1993-07-31

    The GEM collaboration was formed in June 1991 to develop a major detector for the SSC. The primary physics objectives of GEM are those central to the motivation for the SSC, to study high p{sub T} physics - exemplified by the search for Higgs bosons - and to search for new physics beyond the standard model. The authors present in this Technical Design Report (TDR) a detector with broad capabilities for the discovery and subsequent study of electroweak symmetry breaking, the origin of mass and flavor, and other physics requiring precise measurements of gammas, electrons, and muons - hence the name, GEM. In addition, as a design goal, they have taken care to provide the robustness needed to do the physics that requires high luminosity. Finally, good coverage and hermeticity allow the detection of missing transverse energy, E{sub T}. The GEM design emphasizes clean identification and high resolution measurement of the primary physics signatures for high p{sub T} physics. The approach is to make precise energy measurements that maximize the sensitivity to rare narrow resonances, to detect the elementary interaction products (quarks, leptons, and photons), and to build in the features required to reduce backgrounds.

  3. GEM Technical Design Report

    International Nuclear Information System (INIS)

    1993-01-01

    The GEM collaboration was formed in June 1991 to develop a major detector for the SSC. The primary physics objectives of GEM are those central to the motivation for the SSC, to study high p T physics - exemplified by the search for Higgs bosons - and to search for new physics beyond the standard model. The authors present in this Technical Design Report (TDR) a detector with broad capabilities for the discovery and subsequent study of electroweak symmetry breaking, the origin of mass and flavor, and other physics requiring precise measurements of gammas, electrons, and muons - hence the name, GEM. In addition, as a design goal, they have taken care to provide the robustness needed to do the physics that requires high luminosity. Finally, good coverage and hermeticity allow the detection of missing transverse energy, E T . The GEM design emphasizes clean identification and high resolution measurement of the primary physics signatures for high p T physics. The approach is to make precise energy measurements that maximize the sensitivity to rare narrow resonances, to detect the elementary interaction products (quarks, leptons, and photons), and to build in the features required to reduce backgrounds

  4. How to reduce the ion feedback in GEM

    International Nuclear Information System (INIS)

    Park, S. H.; Kang, S. M.; Kim, Y. G.

    2003-01-01

    The feedback of positive ions in Gas Electron Multiplier(GEM) has to be suppressed to reduce the photocathode degradation in GEM photomultiplier and to prevent the field distortion in a Time Projection Chamber(TPC). The ion feedback dependency on the drift electric field, the transfer field, the asymmetry in the voltages across the GEM, and the effective gain was measured in various gases. The ion feedback is sensitive to the drift field and the effective gain. A model prediction of the ion feedback in multiple GEM was compared with the measurement. The ion gating method, which is being studyed in TPC, is introduced to reduce the ion feedback in GEM. With Maxwell and Garfield calculation, we obtained the reduction of the ion feedback by placing the wires between the drift plate and the GEM. We calculated the depedency of the ion feedback with respect to the bias voltage on the wire, the distance between the wires, and the distance between the wire and the GEM

  5. GEM simulation methods development

    International Nuclear Information System (INIS)

    Tikhonov, V.; Veenhof, R.

    2002-01-01

    A review of methods used in the simulation of processes in gas electron multipliers (GEMs) and in the accurate calculation of detector characteristics is presented. Such detector characteristics as effective gas gain, transparency, charge collection and losses have been calculated and optimized for a number of GEM geometries and compared with experiment. A method and a new special program for calculations of detector macro-characteristics such as signal response in a real detector readout structure, and spatial and time resolution of detectors have been developed and used for detector optimization. A detailed development of signal induction on readout electrodes and electronics characteristics are included in the new program. A method for the simulation of charging-up effects in GEM detectors is described. All methods show good agreement with experiment

  6. The gas electron multiplier (GEM)

    CERN Document Server

    Bouclier, Roger; Dominik, Wojciech; Hoch, M; Labbé, J C; Million, Gilbert; Ropelewski, Leszek; Sauli, Fabio; Sharma, A

    1996-01-01

    We describe operating priciples and results obtained with a new detector component: the Gas Electrons Multiplier (GEM). Consisting of a thin composite sheet with two metal layers separated by a thin insulator, and pierced by a regular matrix of open channels, the GEM electrode, inserted on the path of electrons in a gas detector, allows to transfer the charge with an amplification factor approaching ten. Uniform response and high rate capability are demonstrated. Coupled to another device, multiwire or micro-strip chamber, the GEM electrode permit to obtain higher gains or less critical operation; separation of the sensitive (conversion) volume and the detection volume has other advantages, as a built-in delay (useful for triggering purposes) and the possibility of applying high fields on the photo-cathode of ring imaging detectors to improve efficiency. Multiple GEM grids in the same gas volume allow to obtain large amplification factors in a succession of steps, leading to the realization of an effective ga...

  7. First results of spherical GEMs

    CERN Document Server

    Pinto, Serge Duarte; Brock, Ian; Croci, Gabriele; David, Eric; de Oliveira, Rui; Ropelewski, Leszek; van Stenis, Miranda; Taureg, Hans; Villa, Marco

    2010-01-01

    We developed a method to make GEM foils with a spherical geometry. Tests of this procedure and with the resulting spherical GEMs are presented. Together with a spherical drift electrode, a spherical conversion gap can be formed. This eliminates the parallax error for detection of x-rays, neutrons or UV photons when a gaseous converter is used. This parallax error limits the spatial resolution at wide scattering angles. Besides spherical GEMs, we have developed curved spacers to maintain accurate spacing, and a conical field cage to prevent edge distortion of the radial drift field up to the limit of the angular acceptance of the detector. With these components first tests are done in a setup with a spherical entrance window but a planar readout structure; results will be presented and discussed. A flat readout structure poses difficulties, however. Therefore we will show advanced plans to make a prototype of an entirely spherical double-GEM detector, including a spherical 2D readout structure. This detector w...

  8. Recent Developments in GEM-Based Neutron Detectors

    International Nuclear Information System (INIS)

    Saenboonruang, K.

    2014-01-01

    The gas electron multiplier (GEM) detector is a relatively new gaseous detector that has been used for less than 20 years. Since the discovery in 1997 by F. Sauli, the GEM detector has shown excellent properties including high rate capability, excellent resolutions, low discharge probability, and excellent radiation hardness. These promising properties have led the GEM detector to gain popularity and attention amongst physicists and researchers. In particular, the GEM detector can also be modified to be used as a neutron detector by adding appropriate neutron converters. With properties stated above and the need to replace the expensive 3 He-based neutron detectors, the GEM-based neutron detector will be one of the most powerful and affordable neutron detectors. Applications of the GEM-based neutron detectors vary from researches in nuclear and particle physics, neutron imaging, and national security. Although several promising progresses and results have been shown and published in the past few years, further improvement is still needed in order to improve the low neutron detection efficiency (only a few percent) and to widen the possibilities for other uses.

  9. Neutron beam imaging with GEM detectors

    International Nuclear Information System (INIS)

    Albani, G.; Cazzaniga, C.; Rebai, M.; Gorini, G.; Croci, G.; Muraro, A.; Cippo, E. Perelli; Tardocchi, M.; Cavenago, M.; Murtas, F.; Claps, G.; Pasqualotto, R.

    2015-01-01

    Neutron GEM-based detectors represent a new frontier of devices in neutron physics applications where a very high neutron flux must be measured such as future fusion experiments (e.g. ITER Neutral beam Injector) and spallation sources (e.g. the European Spallation source). This kind of detectors can be properly adapted to be used both as beam monitors but also as neutron diffraction detectors that could represent a valid alternative for the 3 He detectors replacement. Fast neutron GEM detectors (nGEM) feature a cathode composed by one layer of polyethylene and one of aluminium (neutron scattering on hydrogen generates protons that are detected in the gas) while thermal neutron GEM detectors (bGEM) are equipped with a borated aluminium cathode (charged particles are generated through the 10 B(n,α) 7 Li reaction). GEM detectors can be realized in large area (1 m 2 ) and their readout can be pixelated. Three different prototypes of nGEM and one prototype of bGEM detectors of different areas and equipped with different types of readout have been built and tested. All the detectors have been used to measure the fast and thermal neutron 2D beam image at the ISIS-VESUVIO beamline. The different kinds of readout patterns (different areas of the pixels) have been compared in similar conditions. All the detectors measured a width of the beam profile consitent with the expected one. The imaging property of each detector was then tested by inserting samples of different material and shape in the beam. All the samples were correctly reconstructed and the definition of the reconstruction depends on the type of readout anode. The fast neutron beam profile reconstruction was then compared to the one obtained by diamond detectors positioned on the same beamline while the thermal neutron one was compared to the imaged obtained by cadmium-coupled x-rays films. Also efficiency and the gamma background rejection have been determined. These prototypes represent the first step towards

  10. GEM - The Global Earthquake Model

    Science.gov (United States)

    Smolka, A.

    2009-04-01

    Over 500,000 people died in the last decade due to earthquakes and tsunamis, mostly in the developing world, where the risk is increasing due to rapid population growth. In many seismic regions, no hazard and risk models exist, and even where models do exist, they are intelligible only by experts, or available only for commercial purposes. The Global Earthquake Model (GEM) answers the need for an openly accessible risk management tool. GEM is an internationally sanctioned public private partnership initiated by the Organisation for Economic Cooperation and Development (OECD) which will establish an authoritative standard for calculating and communicating earthquake hazard and risk, and will be designed to serve as the critical instrument to support decisions and actions that reduce earthquake losses worldwide. GEM will integrate developments on the forefront of scientific and engineering knowledge of earthquakes, at global, regional and local scale. The work is organized in three modules: hazard, risk, and socio-economic impact. The hazard module calculates probabilities of earthquake occurrence and resulting shaking at any given location. The risk module calculates fatalities, injuries, and damage based on expected shaking, building vulnerability, and the distribution of population and of exposed values and facilities. The socio-economic impact module delivers tools for making educated decisions to mitigate and manage risk. GEM will be a versatile online tool, with open source code and a map-based graphical interface. The underlying data will be open wherever possible, and its modular input and output will be adapted to multiple user groups: scientists and engineers, risk managers and decision makers in the public and private sectors, and the public-at- large. GEM will be the first global model for seismic risk assessment at a national and regional scale, and aims to achieve broad scientific participation and independence. Its development will occur in a

  11. Gaseous Electron Multiplier (GEM) Detectors

    Science.gov (United States)

    Gnanvo, Kondo

    2017-09-01

    Gaseous detectors have played a pivotal role as tracking devices in the field of particle physics experiments for the last fifty years. Recent advances in photolithography and micro processing techniques have enabled the transition from Multi Wire Proportional Chambers (MWPCs) and Drift Chambers to a new family of gaseous detectors refer to as Micro Pattern Gaseous Detectors (MPGDs). MPGDs combine the basic gas amplification principle with micro-structure printed circuits to provide detectors with excellent spatial and time resolution, high rate capability, low material budget and high radiation tolerance. Gas Electron Multiplier (GEMs) is a well-established MPGD technology invented by F. Sauli at CERN in 1997 and deployed various high energy physics (HEP) and nuclear NP experiment for tracking systems of current and future NP experiments. GEM detector combines an exceptional high rate capability (1 MHz / mm2) and robustness against harsh radiation environment with excellent position and timing resolution performances. Recent breakthroughs over the past decade have allowed the possibility for large area GEMs, making them cost effective and high-performance detector candidates to play pivotal role in current and future particle physics experiments. After a brief introduction of the basic principle of GEM technology, I will give a brief overview of the GEM detectors used in particle physics experiments over the past decades and especially in the NP community at Thomas Jefferson National Laboratory (JLab) and Brookhaven National Laboratory (BNL). I will follow by a review of state of the art of the new GEM development for the next generation of colliders such as Electron Ion Collider (EIC) or High Luminosity LHC and future Nuclear Physics experiments. I will conclude with a presentation of the CERN-based RD51 collaboration established in 2008 and its major achievements regarding technological developments and applications of MPGDs.

  12. Extending the ISC-GEM Global Earthquake Instrumental Catalogue

    Science.gov (United States)

    Di Giacomo, Domenico; Engdhal, Bob; Storchak, Dmitry; Villaseñor, Antonio; Harris, James

    2015-04-01

    After a 27-month project funded by the GEM Foundation (www.globalquakemodel.org), in January 2013 we released the ISC-GEM Global Instrumental Earthquake Catalogue (1900 2009) (www.isc.ac.uk/iscgem/index.php) as a special product to use for seismic hazard studies. The new catalogue was necessary as improved seismic hazard studies necessitate that earthquake catalogues are homogeneous (to the largest extent possible) over time in their fundamental parameters, such as location and magnitude. Due to time and resource limitation, the ISC-GEM catalogue (1900-2009) included earthquakes selected according to the following time-variable cut-off magnitudes: Ms=7.5 for earthquakes occurring before 1918; Ms=6.25 between 1918 and 1963; and Ms=5.5 from 1964 onwards. Because of the importance of having a reliable seismic input for seismic hazard studies, funding from GEM and two commercial companies in the US and UK allowed us to start working on the extension of the ISC-GEM catalogue both for earthquakes that occurred beyond 2009 and for earthquakes listed in the International Seismological Summary (ISS) which fell below the cut-off magnitude of 6.25. This extension is part of a four-year program that aims at including in the ISC-GEM catalogue large global earthquakes that occurred before the beginning of the ISC Bulletin in 1964. In this contribution we present the updated ISC GEM catalogue, which will include over 1000 more earthquakes that occurred in 2010 2011 and several hundreds more between 1950 and 1959. The catalogue extension between 1935 and 1949 is currently underway. The extension of the ISC-GEM catalogue will also be helpful for regional cross border seismic hazard studies as the ISC-GEM catalogue should be used as basis for cross-checking the consistency in location and magnitude of those earthquakes listed both in the ISC GEM global catalogue and regional catalogues.

  13. Ion feedback effect in the multi GEM structure

    International Nuclear Information System (INIS)

    Park, Se Hwan; Kim, Yong Kyun; Han, Sang Hyo; Ha, Jang Ho; Moon, Byung Soo; Chung, Chong Eun

    2003-01-01

    The feedback of positive ions in a gas electron multiplier (GEM) has to be suppressed to reduce the photocathode degradation in GEM photomultipliers and to prevent the field distortion in a time projection chamber (TPC). The ion feedback dependency on the drift electric field, the transfer field, the asymmetry in the voltages across the GEM, and the effective gain was carefully measured in various gases. The ion feedback is sensitive to the drift field and the effective gain. A model prediction of the ion feedback in a double GEM structure was compared with the measurement. Our systematic study of the ion feedback effect can lead to progress in gas detectors with GEMs.

  14. Study of etching processes in the GEM detectors

    CERN Document Server

    Zavazieva, Darina

    2016-01-01

    Gaseous Electron Multiplier (GEM) detectors are known to operate stably at high gains and high particle fluxes. Though, at very high gains and fluxes it was observed that the insulating polyimide layer between the GEM electrodes gets etched, changing the original shape of the hole, and therefore varying the gain and the energy resolution of the detector. The idea of the project to observe degradation effect of the GEM foils during the Triple GEM detector operation in extreme conditions under X-ray radiation.

  15. Biogenic Emission Inventory System (BEIS)

    Science.gov (United States)

    Biogenic Emission Inventory System (BEIS) estimates volatile organic compound (VOC) emissions from vegetation and nitric oxide (NO) emission from soils. Recent BEIS development has been restricted to the SMOKE system

  16. A GEM of an SSC detector

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    The SSC Laboratory has decided to support the GEM (Gammas, Electrons, and Muons) detector collaboration in the next stage of its work, development of a Technical Design Report. Initial ideas for GEM as the second major SSC detector were aired last year

  17. Die Bandscheibenprothese bei schmerzhafter Diskusdegeneration

    Directory of Open Access Journals (Sweden)

    Ogon M

    2004-01-01

    Full Text Available Bandscheibenprothesen sind indiziert bei Patienten mit einer schmerzhaften Bandscheibendegeneration, einer sogenannten DDD (degenerative disc disease, bei gut erhaltenen Facettengelenken. Kontraindikationen stellen eine Instabilität, eine Spondylarthrose, eine spinale Stenose und eine Osteoporose dar. Bei 19 Patienten mit einem Follow-up von mindestens 12 Monaten fand sich eine durchschnittliche Verbesserung des Oswestry Disability Index von präoperativ 50,8 auf 19,8. Der SF-36 Score zur Erfassung der Lebensqualität besserte sich von 31,5 auf 48,8 (Physical Component Summary Score bzw. von 37,8 auf 44,5 (Mental Component Summary Score im 1-Jahres-Follow-up. Nachhaltige Komplikationen traten nicht auf. Bandscheibenprothesen können heute bei Patienten mit therapieresistenten Kreuzschmerzen als gute Alternative zu einer Wirbelfusion angesehen werden.

  18. Progress in GEM-based gaseous photomultipliers

    CERN Document Server

    Chechik, R; Breskin, Amos; Buzulutskov, A F; Guedes, G P; Mörmann, D; Singh, B K

    2003-01-01

    We discuss recent progress in gaseous photomultipliers (GPMTs) comprising UV-to-visible spectral range photocathodes (PCs) coupled to multiple Gas Electron Multipliers (GEM). The PCs may be either semitransparent or reflective ones directly deposited on the first-GEM surface. These detectors provide high gain, even in noble gases, are sensitive to single photons, have nanosecond time resolution, and offer good localization. The operation of CsI-based GPMTs in CF sub 4 opens new applications in Cherenkov detectors, where both the radiator and the photosensor operate in the same gas. The latest results on sealed visible-light detectors, combining bialkali PCs and Kapton-made GEMs are presented.

  19. 3D Observation of GEMS by Electron Tomography

    Science.gov (United States)

    Matsuno, Junya; Miyake, Akira; Tsuchiyama, Akira; Nakamura-Messenger, Keiko; Messenger, Scott

    2014-01-01

    Amorphous silicates in chondritic porous interplanetary dust particles (CP-IDPs) coming from comets are dominated by glass with embedded metal and sulfides (GEMS). GEMS grains are submicron-sized rounded objects (typically 100-500) nm in diameter) with anaometer-sized (10-50 nm) Fe-Ni metal and sulfide grains embedded in an amorphous silicate matrix. Several formation processes for GEMS grains have been proposed so far, but these models are still being debated [2-5]. Bradley et al. proposed that GEMS grains are interstellar silicate dust that survived various metamorphism or alteration processes in the protoplanetary disk and that they are amorphiation products of crystalline silicates in the interstellar medium by sputter-deposition of cosmic ray irradiation, similar to space weathering [2,4]. This consideration is based on the observation of nano-sized crystals (approximately 10 nm) called relict grains in GEMS grains and their shapes are pseudomorphs to the host GEMS grains. On the other hand, Keller and Messenger proposed that most GEMS formed in the protoplanetary disk as condensates from high temperature gas [3,5]. This model is based on the fact that most GEMS grains have solar isotopic compositions and have extremely heterogeneous and non-solar elemental compositions. Keller and Messenger (2011) also reported that amorphous silicates in GEMS grains are surrounded by sulfide grains, which formed as sulfidization of metallic iron grains located on the GEMS surface. The previous studies were performed with 2D observation by using transmission electron microscopy (TEM) or scanning TEM (STEM). In order to understand the structure of GEMS grains described above more clearly, we observed 3D structure of GEMS grains by electron tomography using a TEM/STEM (JEM-2100F, JEOL) at Kyoto University. Electron tomography gives not only 3D structures but also gives higher spatial resolution (approximately a few nm) than that in conventional 2D image, which is restricted by

  20. Gravity model improvement using GEOS-3 (GEM 9 and 10)

    Science.gov (United States)

    Lerch, F. J.; Klosko, S. M.; Laubscher, R. E.; Wagner, C. A.

    1977-01-01

    The use of collocation permitted GEM 9 to be a larger field than previous derived satellite models, GEM 9 having harmonics complete to 20 x 20 with selected higher degree terms. The satellite data set has approximately 840,000 observations, of which 200,000 are laser ranges taken on 9 satellites equipped with retroreflectors. GEM 10 is complete to 22 x 22 with selected higher degree terms out to degree and order 30 amounting to a total of 592 coefficients. Comparisons with surface gravity and altimeter data indicate a substantial improvement in GEM 9 over previous satellite solutions; GEM 9 is in even closer agreement with surface data than the previously published GEM 6 solution which contained surface gravity. In particular the free air gravity anomalies calculated from GEM 9 and a surface gravity solution are in excellent agreement for the high degree terms.

  1. GEM-based thermal neutron beam monitors for spallation sources

    International Nuclear Information System (INIS)

    Croci, G.; Claps, G.; Caniello, R.; Cazzaniga, C.; Grosso, G.; Murtas, F.; Tardocchi, M.; Vassallo, E.; Gorini, G.; Horstmann, C.; Kampmann, R.; Nowak, G.; Stoermer, M.

    2013-01-01

    The development of new large area and high flux thermal neutron detectors for future neutron spallation sources, like the European Spallation Source (ESS) is motivated by the problem of 3 He shortage. In the framework of the development of ESS, GEM (Gas Electron Multiplier) is one of the detector technologies that are being explored as thermal neutron sensors. A first prototype of GEM-based thermal neutron beam monitor (bGEM) has been built during 2012. The bGEM is a triple GEM gaseous detector equipped with an aluminum cathode coated by 1μm thick B 4 C layer used to convert thermal neutrons to charged particles through the 10 B(n, 7 Li)α nuclear reaction. This paper describes the results obtained by testing a bGEM detector at the ISIS spallation source on the VESUVIO beamline. Beam profiles (FWHM x =31 mm and FWHM y =36 mm), bGEM thermal neutron counting efficiency (≈1%), detector stability (3.45%) and the time-of-flight spectrum of the beam were successfully measured. This prototype represents the first step towards the development of thermal neutrons detectors with efficiency larger than 50% as alternatives to 3 He-based gaseous detectors

  2. Precise Point Positioning with the BeiDou Navigation Satellite System

    Directory of Open Access Journals (Sweden)

    Min Li

    2014-01-01

    Full Text Available By the end of 2012, China had launched 16 BeiDou-2 navigation satellites that include six GEOs, five IGSOs and five MEOs. This has provided initial navigation and precise pointing services ability in the Asia-Pacific regions. In order to assess the navigation and positioning performance of the BeiDou-2 system, Wuhan University has built up a network of BeiDou Experimental Tracking Stations (BETS around the World. The Position and Navigation Data Analyst (PANDA software was modified to determine the orbits of BeiDou satellites and provide precise orbit and satellite clock bias products from the BeiDou satellite system for user applications. This article uses the BeiDou/GPS observations of the BeiDou Experimental Tracking Stations to realize the BeiDou and BeiDou/GPS static and kinematic precise point positioning (PPP. The result indicates that the precision of BeiDou static and kinematic PPP reaches centimeter level. The precision of BeiDou/GPS kinematic PPP solutions is improved significantly compared to that of BeiDou-only or GPS-only kinematic PPP solutions. The PPP convergence time also decreases with the use of combined BeiDou/GPS systems.

  3. Precise point positioning with the BeiDou navigation satellite system.

    Science.gov (United States)

    Li, Min; Qu, Lizhong; Zhao, Qile; Guo, Jing; Su, Xing; Li, Xiaotao

    2014-01-08

    By the end of 2012, China had launched 16 BeiDou-2 navigation satellites that include six GEOs, five IGSOs and five MEOs. This has provided initial navigation and precise pointing services ability in the Asia-Pacific regions. In order to assess the navigation and positioning performance of the BeiDou-2 system, Wuhan University has built up a network of BeiDou Experimental Tracking Stations (BETS) around the World. The Position and Navigation Data Analyst (PANDA) software was modified to determine the orbits of BeiDou satellites and provide precise orbit and satellite clock bias products from the BeiDou satellite system for user applications. This article uses the BeiDou/GPS observations of the BeiDou Experimental Tracking Stations to realize the BeiDou and BeiDou/GPS static and kinematic precise point positioning (PPP). The result indicates that the precision of BeiDou static and kinematic PPP reaches centimeter level. The precision of BeiDou/GPS kinematic PPP solutions is improved significantly compared to that of BeiDou-only or GPS-only kinematic PPP solutions. The PPP convergence time also decreases with the use of combined BeiDou/GPS systems.

  4. ROLE OF GEMS IN INDIAN MEDICINE

    Science.gov (United States)

    Murthy, S.R.N.

    1991-01-01

    This paper is the first attempt in introducing the medicinal importance of gems as found in the Sanskrit text ‘Rasaratnasamuccaya’, which has been rendered an English translation here. The modern physicians and gemologists will find this study quite useful in continuing research and, thus, develop a new field of gem medicine. PMID:22556526

  5. SUPERCOLLIDER: A GEM of a detector

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    Now being prepared as a major experimental facility for the 87- kilometre Superconducting Supercollider (SSC) being built in Ellis County, Texas, is the GEM detector project. GEM thus becomes the companion to the Solenoidal Detector Collaboration (SDC), the first major SSC detector to emerge (March 1992, page 13). This is in keeping with the SSC Laboratory's aim of two major detectors with overlapping and complementary strengths. GEM is designed to observe all SSC signatures, with emphasis on precise measurement of electrons, photons and muons. Hence the name GEM - ''Gammas, Electrons and Muons.'' Design goals are clean signatures for leptons, jets, and missing transverse energy, maximum sensitivity to narrow resonances, and low backgrounds. Also important is maintaining significant capability at high luminosity (10 34 cm -2 s -1 ). GEM has some distinctive features. A key concept is the exterior magnet, surrounding all detector elements. Inside the magnet are a muon tracking system, a precision calorimeter, and a compact central tracker. This allows the muon momentum to be measured the air of the radiation shielded area outside the thick calorimeter, giving both high precision and robustness at high luminosity. A large magnet gives a large lever arm (at least 4 m) for precise muon momentum measurement. Placing the magnet outside also minimizes the material between tracker and calorimeters, so that the calorimeters are limited only by their inherent resolutions

  6. Mehrfacheffekt-Feuchtluftdestillation bei Umgebungsdruck

    OpenAIRE

    Müller-Holst, Hendrik

    2007-01-01

    Ein neuartiges Verfahren zur Feuchtluftdestillation mittels Verdunstung und Kondensation in einer einzigen Kammer wurde im Rahmen der Arbeit umfassend analysiert. Das Verfahren arbeitet bei Umgebungsdruck; der dadurch bei Temperaturen unter dem Siedepunkt verringerte Stoffübergang wird durch große Austauschflächen mit hoher Packungsdichte kompensiert. Der Transport der im Verdunster beladenen Feuchtluft zum Kondensator erfolgt innerhalb einer optimierten geometrischen Anordnung der Baueinheit...

  7. New Approach for 2D Readout of GEM Detectors

    International Nuclear Information System (INIS)

    Hasell, Douglas K.

    2011-01-01

    Detectors based on Gas Electron Multiplication (GEM) technology are becoming more and more widely used in nuclear and high energy physics and are being applied in astronomy, medical physics, industry, and homeland security. GEM detectors are thin, low mass, insensitive to magnetic fields, and can currently provide position resolutions down to ∼50 microns. However, the designs for reconstructing the position, in two dimensions (2D), of the charged particles striking a GEM detector are often complicated to fabricate and expensive. The objective of this proposal is to investigate a simpler procedure for producing the two dimensional readout layer of GEM detectors using readily available printed circuit board technology which can be tailored to the detector requirements. We will use the established GEM laboratory and facilities at M.I.T. currently employed in developing GEM detectors for the STAR forward tracking upgrade to simplify the testing and evaluation of the new 2D readout designs. If this new design proves successful it will benefit future nuclear and high energy physics experiments already being planned and will similarly extend and simplify the application of GEM technology to other branches of science, medicine, and industry. These benefits would be not only in lower costs for fabrication but also it increased flexibility for design and application.

  8. Analysis of activation yields by INC/GEM

    International Nuclear Information System (INIS)

    Furihata, Shiori; Nakashima, Hiroshi

    2001-01-01

    Excitation functions of the nuclides produced from the reaction on nitrogen and oxygen target irradiated by nucleons are analyzed using INC/GEM. It is shown that INC/GEM reproduces most of the cross sections within a factor of two to three. (author)

  9. Complete Tem-Tomography: 3D Structure of Gems Cluster

    Science.gov (United States)

    Matsuno, J.; Miyake, A.; Tsuchiyama, A.; Messenger, S.; Nakamura-Messenger, K.

    2015-01-01

    GEMS (glass with embedded metal and sulfide) grains in interplanetary dust particles (IDPs) are considered to be one of the ubiquitous and fundamental building blocks of solids in the Solar System. They have been considered to be interstellar silicate dust that survived various metamorphism or alteration processes in the protoplanetary disk but the elemental and isotopic composition measurements suggest that most of them have been formed in the protoplanetary disk as condensates from high temperature gas. This formation model is also supported by the formation of GEMS-like grains with respect to the size, mineral assemblage, texture and infrared spectrum by condensation experiments from mean GEMS composition materials. Previous GEMS studies were performed only with 2D observation by transmission electron microscopy (TEM) or scanning TEM (STEM). However, the 3D shape and structure of GEMS grains and the spatial distribution of Fe/FeS's has critical information about their formation and origin. Recently, the 3D structure of GEMS grains in ultrathin sections of cluster IDPs was revealed by electron tomography using a TEM/STEM (JEM-2100F, JEOL). However, CT images of thin sections mounted on Cu grids acquired by conventional TEM-tomography are limited to low tilt angles (e. g., less than absolute value of 75 deg. In fact, previous 3D TEM observations of GEMS were affected by some artifacts related to the limited tilt range in the TEM used. Complete tomographic images should be acquired by rotating the sample tilt angle over a range of more than absolute value of 80 deg otherwise the CT images lose their correct structures. In order to constrain the origin and formation process of GEMS grains more clearly, we performed complete electron tomography for GEMS grains. Here we report the sample preparation method we have developed for this study, and the preliminary results.

  10. Development of Gas Electron Multiplier(GEM) for digital radiographic system

    International Nuclear Information System (INIS)

    Moon, B. S.; Chung, C. E.; Lee, J. W.

    2000-04-01

    Two computer programs SHOWFIELD and IMAGEQUAL have been developed. SHOWFIELD is used to draw electric field lines for GEM detectors and IMAGEQUAL is used to study the spatial resolution of x-ray images. Various simulation runs have been carried out using EGS4 to study the characteristics of electrons generated by micro-channel plates and Ar, Xe gases. A prototype GEM detector was developed through this project. The GEM detector is composed of a pair of GEM plates, a micro-channel plate, readout circuit in a gas filled chamber. GEM plate were made in CERN to meet KAERI's design specification and the micro-channel plates were purchased from Proxitronic company

  11. The determination of the orbit of the Japanese satellite Ajisai and the GEM-T1 and GEM-T2 gravity field models

    Science.gov (United States)

    Sanchez, Braulio V.

    1990-01-01

    The Japanese Experimental Geodetic Satellite Ajisai was launched on August 12, 1986. In response to the TOPEX-POSEIDON mission requirements, the GSFC Space Geodesy Branch and its associates are producing improved models of the Earth's gravitational field. With the launch of Ajisai, precise laser data is now available which can be used to test many current gravity models. The testing of the various gravity field models show improvements of more than 70 percent in the orbital fits when using GEM-T1 and GEM-T2 relative to results obtained with the earlier GEM-10B model. The GEM-T2 orbital fits are at the 13-cm level (RMS). The results of the tests with the various versions of the GEM-T1 model indicate that the addition of satellite altimetry and surface gravity anomalies as additional data types should improve future gravity field models.

  12. 1950'erne

    DEFF Research Database (Denmark)

    Mortensen, Tore; Høyer, Ole Izard

    2011-01-01

    Dansk jazz' historie i 1950erne, om musikerne or orkestrene, om danserestauranterne, den moderne scene og klubmiljøerne, spillestederne, radioens jazzoplysning, jazzen i medierne, jazzlitteraturen, jazzakademiet og debatterne.......Dansk jazz' historie i 1950erne, om musikerne or orkestrene, om danserestauranterne, den moderne scene og klubmiljøerne, spillestederne, radioens jazzoplysning, jazzen i medierne, jazzlitteraturen, jazzakademiet og debatterne....

  13. Gas electron multiplier (GEM) foil test, repair and effective gain calculation

    Science.gov (United States)

    Tahir, Muhammad; Zubair, Muhammad; Khan, Tufail A.; Khan, Ashfaq; Malook, Asad

    2018-06-01

    The focus of my research is based on the gas electron multiplier (GEM) foil test, repairing and effective gain calculation of GEM detector. During my research work define procedure of GEM foil testing short-circuit, detection short-circuits in the foil. Study different ways to remove the short circuits in the foils. Set and define the GEM foil testing procedures in the open air, and with nitrogen gas. Measure the leakage current of the foil and applying different voltages with specified step size. Define the Quality Control (QC) tests and different components of GEM detectors before assembly. Calculate the effective gain of GEM detectors using 109Cd and 55Fe radioactive source.

  14. Progress of BeiDou time transfer at NTSC

    Science.gov (United States)

    Guang, Wei; Dong, Shaowu; Wu, Wenjun; Zhang, Jihai; Yuan, Haibo; Zhang, Shougang

    2018-04-01

    Time transfer using global navigation satellite system (GNSS) is a primary method of remote atomic clock comparisons. As of today, there are four operational GNSS systems, namely GPS, GLONASS, Galileo and BeiDou Navigation Satellite System (BDS or BeiDou). All of them can continuously provide position, navigation and time services. This paper mainly focuses on the progress of BeiDou time transfer at the National Time Service Center, Chinese Academy of Sciences (NTSC). In order to realize the BeiDou common view (CV) time comparison, we developed the Rinex2CGGTTS software according to the guidelines of the Common GNSS Generic Time Transfer Standard, Version 2E (CGGTTS V2E). By comparing the solutions of the Rinex2CGGTTS software to the solutions of the sbf2cggtts software provided by the manufacturer of our multi-GNSS receiver, we found the sbf2cggtts (version 1.0.5) solutions contained biases in measurements to different BeiDou satellites. The biases are most likely caused by sbf2cggtts’ timing group delay corrections in data processing. The noise of the observation data is analyzed by code multipath and common clock difference. Finally, the BeiDou CV results are compared to the GPS/GLONASS/Galileo CV results between NTSC and three European UTC(k) laboratories, including Royal Observatory of Belgium (ORB), Real Institute y Observatory de la Armada (ROA), Research Institutes of Sweden (RISE or SP). For the comparisons of each baseline, we aligned the BeiDou/Galileo/GLONASS links to the calibrated GPS link with the double-difference method. The results show that the performance of BeiDou CV is correlated to the number of BeiDou satellites available in common view. With the current BeiDou constellation, the standard deviation of the differences between all BeiDou CV satellites averaging result and the GPS PPP result is 2.03 ns, 2.90 ns and 4.06 ns for ORB-NTSC, SP-NTSC and ROA-NTSC links respectively.

  15. Analysis of GEM properties and development of a GEM support structure for the ILD time projection chamber

    International Nuclear Information System (INIS)

    Hallermann, Lea

    2010-04-01

    In the concept of the International Large Detector (ILD), developed for the International Linear Collider (ILC) a Time Projection Chamber (TPC) is envisaged as main tracking detector. Such gaseous detectors have to be equipped with amplification devices in order to enlarge the amount of charge, which is set free by ionization caused by traversing charged particles. Micro Pattern Gas Detectors (MPGDs) will be used in the ILD TPC as amplification stage. In this thesis, Gas Electron Multipliers (GEMs) - one specific MPGD species - are analyzed concerning various properties. Effective gains and energy resolutions are compared for GEM foils produced by different manufacturers. A good understanding of these observables is obtained by interpretation of the results with the help of geometrical parameters. Height profile measurements of GEM foils have been performed for the first time and the impact of non perfect flat GEMs is analyzed, especially on dE/dx determination and drift field quality. The results emphasize the need of a flat installation of GEMs in TPCs. As a consequence, a new mounting device has been developed to ensure flatness and to provide a method to cover large readout areas, as in the ILD TPC, by introducing the least possible amount of dead material into the detector. The developed structure has been tested in a TPC protoype, taking cosmic muon data. The influence of the mounting on track reconstruction, single point resolution, tracking efficiency and dE/dx measurements is quantified. The developed mounting is applicable in a large scale TPC, if some design considerations are taken into account. (orig.)

  16. Analysis of GEM properties and development of a GEM support structure for the ILD time projection chamber

    Energy Technology Data Exchange (ETDEWEB)

    Hallermann, Lea

    2010-04-15

    In the concept of the International Large Detector (ILD), developed for the International Linear Collider (ILC) a Time Projection Chamber (TPC) is envisaged as main tracking detector. Such gaseous detectors have to be equipped with amplification devices in order to enlarge the amount of charge, which is set free by ionization caused by traversing charged particles. Micro Pattern Gas Detectors (MPGDs) will be used in the ILD TPC as amplification stage. In this thesis, Gas Electron Multipliers (GEMs) - one specific MPGD species - are analyzed concerning various properties. Effective gains and energy resolutions are compared for GEM foils produced by different manufacturers. A good understanding of these observables is obtained by interpretation of the results with the help of geometrical parameters. Height profile measurements of GEM foils have been performed for the first time and the impact of non perfect flat GEMs is analyzed, especially on dE/dx determination and drift field quality. The results emphasize the need of a flat installation of GEMs in TPCs. As a consequence, a new mounting device has been developed to ensure flatness and to provide a method to cover large readout areas, as in the ILD TPC, by introducing the least possible amount of dead material into the detector. The developed structure has been tested in a TPC protoype, taking cosmic muon data. The influence of the mounting on track reconstruction, single point resolution, tracking efficiency and dE/dx measurements is quantified. The developed mounting is applicable in a large scale TPC, if some design considerations are taken into account. (orig.)

  17. nGEM fast neutron detectors for beam diagnostics

    International Nuclear Information System (INIS)

    Croci, G.; Claps, G.; Cavenago, M.; Dalla Palma, M.; Grosso, G.; Murtas, F.; Pasqualotto, R.; Perelli Cippo, E.; Pietropaolo, A.; Rebai, M.; Tardocchi, M.; Tollin, M.; Gorini, G.

    2013-01-01

    Fast neutron detectors with a sub-millimetric space resolution are required in order to qualify neutron beams in applications related to magnetically-controlled nuclear fusion plasmas and to spallation sources. A nGEM detector has been developed for the CNESM diagnostic system of the SPIDER NBI prototype for ITER and as beam monitor for fast neutrons lines at spallation sources. The nGEM is a triple GEM gaseous detector equipped with polypropylene and polyethylene layers used to convert fast neutrons into recoil protons through the elastic scattering process. This paper describes the results obtained by testing a nGEM detector at the ISIS spallation source on the VESUVIO beam line. Beam profiles (σ x =14.35 mm, σ y =15.75 mm), nGEM counting efficiency (around 10 -4 for 3 MeV n <15 MeV), detector stability (≈4.5%) and the effect of filtering the beam with different type of materials were successfully measured. The x beam profile was compared to the one measured by a single crystal diamond detector. Finally, the efficiency of the detector was simulated exploiting the GEANT4 tool

  18. GEMS Revealed: Spectrum Imaging of Aggregate Grains in Interplanetary Dust

    Science.gov (United States)

    Keller, L. P.; Messenger, S.; Christoffersen, R.

    2005-01-01

    Anhydrous interplanetary dust particles (IDPs) of cometary origin contain abundant materials that formed in the early solar nebula. These materials were transported outward and subsequently mixed with molecular cloud materials and presolar grains in the region where comets accreted [1]. GEMS (glass with embedded metal and sulfides) grains are a major component of these primitive anhydrous IDPs, along with crystalline Mg-rich silicates, Fe-Ni sulfides, carbonaceous material, and other trace phases. Some GEMS grains (5%) are demonstrably presolar based on their oxygen isotopic compositions [2]. However, most GEMS grains are isotopically solar and have bulk chemical compositions that are incompatible with inferred compositions of interstellar dust, suggesting a solar system origin [3]. An alternative hypothesis is that GEMS grains represent highly irradiated interstellar grains whose oxygen isotopic compositions were homogenized through processing in the interstellar medium (ISM) [4]. We have obtained the first quantitative X-ray maps (spectrum images) showing the distribution of major and minor elements in individual GEMS grains. Nanometer-scale chemical maps provide critical data required to evaluate the differing models regarding the origin of GEMS grains.

  19. The GEM Detector projective alignment simulation system

    International Nuclear Information System (INIS)

    Wuest, C.R.; Belser, F.C.; Holdener, F.R.; Roeben, M.D.; Paradiso, J.A.; Mitselmakher, G.; Ostapchuk, A.; Pier-Amory, J.

    1993-01-01

    Precision position knowledge (< 25 microns RMS) of the GEM Detector muon system at the Superconducting Super Collider Laboratory (SSCL) is an important physics requirement necessary to minimize sagitta error in detecting and tracking high energy muons that are deflected by the magnetic field within the GEM Detector. To validate the concept of the sagitta correction function determined by projective alignment of the muon detectors (Cathode Strip Chambers or CSCs), the basis of the proposed GEM alignment scheme, a facility, called the ''Alignment Test Stand'' (ATS), is being constructed. This system simulates the environment that the CSCs and chamber alignment systems are expected to experience in the GEM Detector, albeit without the 0.8 T magnetic field and radiation environment. The ATS experimental program will allow systematic study and characterization of the projective alignment approach, as well as general mechanical engineering of muon chamber mounting concepts, positioning systems and study of the mechanical behavior of the proposed 6 layer CSCs. The ATS will consist of a stable local coordinate system in which mock-ups of muon chambers (i.e., non-working mechanical analogs, representing the three superlayers of a selected barrel and endcap alignment tower) are implemented, together with a sufficient number of alignment monitors to overdetermine the sagitta correction function, providing a self-consistency check. This paper describes the approach to be used for the alignment of the GEM muon system, the design of the ATS, and the experiments to be conducted using the ATS

  20. GEM1: First-year modeling and IT activities for the Global Earthquake Model

    Science.gov (United States)

    Anderson, G.; Giardini, D.; Wiemer, S.

    2009-04-01

    GEM is a public-private partnership initiated by the Organisation for Economic Cooperation and Development (OECD) to build an independent standard for modeling and communicating earthquake risk worldwide. GEM is aimed at providing authoritative, open information about seismic risk and decision tools to support mitigation. GEM will also raise risk awareness and help post-disaster economic development, with the ultimate goal of reducing the toll of future earthquakes. GEM will provide a unified set of seismic hazard, risk, and loss modeling tools based on a common global IT infrastructure and consensus standards. These tools, systems, and standards will be developed in partnership with organizations around the world, with coordination by the GEM Secretariat and its Secretary General. GEM partners will develop a variety of global components, including a unified earthquake catalog, fault database, and ground motion prediction equations. To ensure broad representation and community acceptance, GEM will include local knowledge in all modeling activities, incorporate existing detailed models where possible, and independently test all resulting tools and models. When completed in five years, GEM will have a versatile, penly accessible modeling environment that can be updated as necessary, and will provide the global standard for seismic hazard, risk, and loss models to government ministers, scientists and engineers, financial institutions, and the public worldwide. GEM is now underway with key support provided by private sponsors (Munich Reinsurance Company, Zurich Financial Services, AIR Worldwide Corporation, and Willis Group Holdings); countries including Belgium, Germany, Italy, Singapore, Switzerland, and Turkey; and groups such as the European Commission. The GEM Secretariat has been selected by the OECD and will be hosted at the Eucentre at the University of Pavia in Italy; the Secretariat is now formalizing the creation of the GEM Foundation. Some of GEM's global

  1. Game programming gems

    CERN Document Server

    DeLoura, Mark

    2000-01-01

    For the countless tasks involved in creating a game engine there are an equal number of possible solutions. But instead of spending hours and hours trying to develop your own answers, now you can find out how the pros do it! Game Programming Gems is a hands-on, comprehensive resource packed with a variety of game programming algorithms written by experts from the game industry and edited by Mark DeLoura, former software engineering lead for Nintendo of America, Inc. and now the newly appointed editor-in-chief of Game Developer magazine. From animation and artificial intelligence to Z-buffering, lighting calculations, weather effects, curved surfaces, mutliple layer Internet gaming, to music and sound effects, all of the major techniques needed to develop a competitive game engine are covered. Game Programming Gems is written in a style accessible to individuals with a range of expertise levels. All of the source code for each algorithm is included and can be used by advanced programmers immediately. For aspir...

  2. GEM - A novel gaseous particle detector

    CERN Document Server

    Meinschad, T

    2005-01-01

    The work carried out within the framework of this Ph.D. deals with the construction of gaseous prototype detectors using Gas Electron Multiplier electrodes for the amplification of charges released by ionizing particles. The Gas Electron Multiplier (GEM) is a thin metal-clad polymer foil, etched with a high density of narrow holes, typically 50-100mm-2. On the application of a potential difference between the conductive top and bottom sides each hole acts as independent proportional counter. This new fast device permits to reach large amplification factors at high rates with a strong photon and ion-mediated feedback suppression due to the avalanche confinement in the GEM-holes. Here, in particular studies have been performed, which should prove, that the GEM-technology is applicable for an efficient measurement of single Cherenkov photons. These UV-photons can be detected in different ways. An elegant solution to develop large area RICH-detectors is to evaporate a pad-segmented readout-cathode of a multi-wire...

  3. Gain uniformity experimental study performed on triple-GEM gas detector

    International Nuclear Information System (INIS)

    Dong Liyuan; Qi Huirong; Lu Xinyu; Ouyang Qun; Chen Yuanbo; Li Yuhong

    2012-01-01

    With the application of the two-dimensional GEM gaseous detector in X-ray imaging, the correction method of gain uniformity caused by triple-GEM avalanche structures and electric field uniformity should be studied. The paper reported the study of the triple-GEM detector with effective area 100 mm × 100 mm used the Pad's size of 9.5 mm × 9.5 mm. In the test, 100 readout channels were designed. Results showed that gain remained stable over time; at air flow increases, gain from increases obviously to changes very little. Particularly, triple-GEM's gain uniformity was very good (more than 80%) and the range of energy resolution was from 0.18 to 0.2. To improve gain consistency of results, the difference value revised was obtained to be about 0.1 by the least square method. It provided a better method to improve gain uniformity of GEM detector. (authors)

  4. A gravity model for crustal dynamics (GEM-L2)

    Science.gov (United States)

    Lerch, F. J.; Klosko, S. M.; Patel, G. B.; Wagner, C. A.

    1985-01-01

    The Laser Geodynamics Satellite (Lageos) was the first NASA satellite which was placed into orbit exclusively for laser ranging applications. Lageos was designed to permit extremely accurate measurements of the earth's rotation and the movement of the tectonic plates. The Goddard earth model, GEM-L2, was derived mainly on the basis of the precise laser ranging data taken on many satellites. Douglas et al. (1984) have demonstrated the utility of GEM-L2 in detecting the broadest ocean circulations. As Lageos data constitute the most extensive set of satellite laser observations ever collected, the incorporation of 2-1/2 years of these data into the Goddard earth models (GEM) has substantially advanced the geodynamical objectives. The present paper discusses the products of the GEM-L2 solution.

  5. X-Ray Polarimetry with GEMS

    Science.gov (United States)

    Strohmayer, Tod

    2011-01-01

    The polarization properties of cosmic X-ray sources are still largely unexplored. The Gravity and Extreme Magnetism SMEX (GEMS) will carry out the first sensitive X-ray polarization survey of a wide range of sources including; accreting compact objects (black holes and neutron stars), AGN, supernova remnants, magnetars and rotation-powered pulsars. GEMS employs grazing-incidence foil mirrors and novel time-projection chamber (TPC) polarimeters leveraging the photoelectric effect to achieve high polarization sensitivity in the 2 - 10 keV band. I will provide an update of the project status, illustrate the expected performance with several science examples, and provide a brief overview of the data analysis challenges

  6. Simulation of the dielectric charging-up effect in a GEM detector

    International Nuclear Information System (INIS)

    Alfonsi, M.; Croci, G.; Duarte Pinto, S.; Rocco, E.; Ropelewski, L.; Sauli, F.; Veenhof, R.; Villa, M.

    2012-01-01

    The charging up effect is well-known in detectors containing dielectric materials and it is due to electrons and ions liberated in an avalanche and collected on the dielectric surfaces. In particular in Gas Electron Multiplier (GEM) based detectors, charges can be captured by the Kapton that separates top and bottom electrodes. The collection of a substantial number of charges on the dielectric surfaces induces a modification of the field inside the GEM holes that implies important consequences on some fundamental parameters such as the electron transparency and the effective gain. The correct simulation of this effect opens new ways to the detailed study of the processes that happens in a GEM-based detector and gives the possibility to optimise the GEM geometry in order to avoid it. This paper compares results of the measurements and the simulations, with and without the introduction of the charging-up effect, of the GEM electron transparency in the case of a single GEM detector. The introduction of the charging up effect in the simulation resulted to be crucial in order to get the proper agreement with the measurements. The measurements and simulations of the GEM effective gain will be the subject of a future work.

  7. Osteoporose bei Spondylitis ankylosans - Einfluß von Lebensgewohnheiten

    Directory of Open Access Journals (Sweden)

    Aglas F

    2004-01-01

    Full Text Available Krankheitsbedingte Artefakte können bei der SpA (Spondylitis ankylosans; Mb. Bechterew die Sensitivität einer Knochendichtemessung im Lumbalbereich beeinträchtigen. Das bei dieser rheumatischen Erkrankung bekannte Osteoporoserisiko ist neben genetischen Faktoren und Entzündungsmechanismen auch von verschiedenen exogenen Einflüssen abhängig. An 47 SpA-Patienten wurde mittels DEXA eine vergleichende Knochendichtemessung (BMD an der Hüfte (Schenkelhals und Ward'sches Dreieck sowie im Bereich der Wirbelsäule (L1-L4 vorgenommen. Zusätzlich erfolgte eine Erhebung der Lebens-Ernährungsgewohnheiten der SpA-Patienten in bezug auf die BMD, um exogene Einflüsse erfassen zu können. Die Knochendichtemessungen ergaben an der LWS wesentlich häufiger eine BMD im Normbereich als am proximalen Femur. Besonders deutliche Unterschiede traten im höheren Lebensalter auf, bei dem aufgrund von Kalzifizierungsvorgängen und Syndesmophyten an der LWS fälschlicherweise eine Dichtezunahme vorgetäuscht wird. Es kann daher bei SpA empfohlen werden, die wesentlich sensitivere Dichtemessung am Schenkelhals durchzuführen. Die über einen Zeitraum von 3 Jahren beobachteten, signifikant erhöhten, medianen CRP-Spiegel zeigen, daß eine permanente Aktivierung von Entzündungsprozessen bei SpA auch einen negativen Faktor betreffend des Knochenmasseverlustes darstellt. Die Analyse der Lebensgewohnheiten ergab, daß SpA-Patienten mit normaler BMD ausnahmslos regelmäßig kalziumreiche Nahrungsmittel zu sich nehmen; bei verminderter BMD wurde in der Mehrheit ein fehlender Konsum an Milchprodukten beobachtet. Leider war auch mit abnehmender BMD eine Verminderung der bei SpA empfohlenen Bewegungsübungen festzustellen. Aufgrund der Resultate ergibt sich eine generelle Empfehlung zu regelmäßigen Bewegungsübungen plus Osteoporosediät bei allen Bechterew-Patienten.

  8. Overcoming the Challenges of BeiDou Receiver Implementation

    Directory of Open Access Journals (Sweden)

    Mohammad Zahidul H. Bhuiyan

    2014-11-01

    Full Text Available Global Navigation Satellite System (GNSS-based positioning is experiencing rapid changes. The existing GPS and the GLONASS systems are being modernized to better serve the current challenging applications under harsh signal conditions. These modernizations include increasing the number of transmission frequencies and changes to the signal components. In addition, the Chinese BeiDou Navigation Satellite system (BDS and the European Galileo are currently under development for global operation. Therefore, in view of these new upcoming systems the research and development of GNSS receivers has been experiencing a new upsurge. In this article, the authors discuss the main functionalities of a GNSS receiver in view of BDS. While describing the main functionalities of a software-defined BeiDou receiver, the authors also highlight the similarities and differences between the signal characteristics of the BeiDou B1 open service signal and the legacy GPS L1 C/A signal, as in general they both exhibit similar characteristics. In addition, the authors implement a novel acquisition technique for long coherent integration in the presence of NH code modulation in BeiDou D1 signal. Furthermore, a simple phase-preserved coherent integration based acquisition scheme is implemented for BeiDou GEO satellite acquisition. Apart from the above BeiDou-specific implementations, a novel Carrier-to-Noise-density ratio estimation technique is also implemented in the software receiver, which does not necessarily require bit synchronization prior to estimation. Finally, the authors present a BeiDou-only position fix with the implemented software-defined BeiDou receiver considering all three satellite constellations from BDS. In addition, a true multi-GNSS position fix with GPS and BDS systems is also presented while comparing their performances for a static stand-alone code phase-based positioning.

  9. BEI Resource Repository

    Data.gov (United States)

    U.S. Department of Health & Human Services — BEI Resources provides reagents, tools and information for studying Category A, B, and C priority pathogens, emerging infectious disease agents, non-pathogenic...

  10. Toward improved guideline quality: using the COGS statement with GEM.

    Science.gov (United States)

    Shiffman, Richard N; Michel, Georges

    2004-01-01

    The Conference on Guideline Standardization (COGS) was convened to create a standardized documentation checklist for clinical practice guidelines in an effort to promote guideline quality and facilitate implementation. The statement was created by a multidisciplinary panel using a rigorous consensus development methodology. The Guideline Elements Model (GEM) provides a standardized approach to representing guideline documents using XML. In this work, we demonstrate the sufficiency of GEM for describing COGS components. Using the mapping between COGS and GEM elements we built an XSLT application to examine a guideline's adherence (or non-adherence) to the COGS checklist. Once a guideline has been marked up according to the GEM hierarchy, its knowledge content can be reused in multiple ways.

  11. Performance of GEM detectors in high intensity particle beams

    CERN Document Server

    Bachmann, S; Ketzer, B; Deutel, M; Ropelewski, Leszek; Sauli, Fabio; Bondar, A E; Buzulutskov, A F; Shekhtman, L I; Sokolov, A; Tatarinov, A A; Vasilev, A; Kappler, S; Schulte, E C

    2001-01-01

    We describe extensive tests of Double GEM and Triple GEM detectors, including full size prototypes for the COMPASS experiment, exposed to high intensity muon, proton and pion beams at the Paul~Scherrer Institute and at CERN. The measurements aim at detecting problems possible under these operation conditions, the main concern being the occurrence of discharges induced by beam particles. Results on the dependence of the probability for induced discharges on the experimental environment are presented and discussed. Implications for the application of GEM~detectors in experiments at high luminosity colliders are illustrated.

  12. Summer Student Project: GEM Simulation and Gas Mixture Characterization

    CERN Document Server

    Oviedo Perhavec, Juan Felipe

    2013-01-01

    Abstract This project is a numerical simulation approach to Gas Electron Multiplier (GEM) detectors design. GEMs are a type of gaseous ionization detector that have proposed as an upgrade for CMS muon endcap. The main advantages of this technology are high spatial and time resolution and outstanding aging resistance. In this context, fundamental physical behavior of a Gas Electron Multiplier (GEM) is analyzed using ANSYS and Garfield++ software coupling. Essential electron transport properties for several gas mixtures were computed as a function of varying electric and magnetic field using Garfield++ and Magboltz.

  13. Possible Gems and Ultra-Fine Grained Polyphase Units in Comet Wild 2.

    Science.gov (United States)

    Gainsforth, Z.; Butterworth, A. L.; Jilly-Rehak, C. E.; Westphal, A. J.; Brownlee, D. E.; Joswiak, D.; Ogliore, R. C.; Zolensky, M. E.; Bechtel, H. A.; Ebel, D. S.; hide

    2016-01-01

    GEMS and ultrafine grained polyphase units (UFG-PU) in anhydrous IDPs are probably some of the most primitive materials in the solar system. UFG-PUs contain nanocrystalline silicates, oxides, metals and sulfides. GEMS are rounded approximately 100 nm across amorphous silicates containing embedded iron-nickel metal grains and sulfides. GEMS are one of the most abundant constituents in some anhydrous CPIDPs, often accounting for half the material or more. When NASA's Stardust mission returned with samples from comet Wild 2 in 2006, it was thought that UFG-PUs and GEMS would be among the most abundant materials found. However, possibly because of heating during the capture process in aerogel, neither GEMS nor UFG-PUs have been clearly found.

  14. Investigations of the long-term stability of a GEM-TPC

    Energy Technology Data Exchange (ETDEWEB)

    Fedorchuk, Oleksiy [Deutsches Elektronen-Synchrotron (DESY), Notkestrasse 85, 22607 Hamburg (Germany); Universitaet Hamburg, Institut fuer Experimentalphysik, Luruper Chaussee 149, 22761 Hamburg (Germany); Collaboration: LCTPC-Deutschland-Collaboration

    2016-07-01

    For the International Large Detector (ILD) at the planned International Linear Collider (ILC) a Time Projection Chamber (TPC) is foreseen as the main tracking detector. The gas amplification will be done by Micro Pattern Gaseous Detectors (MPGD). One option is to use Gas Electron Multipliers (GEM).While the applicability of GEMs for the gas amplification in a TPC readout has been shown, the focus of the current research is to improve the high voltage stability and reliability of the readout modules. This is a crucial requirement for the operation in the final ILD TPC. The main focus of the research presented in this talk is on studies of the discharge stability and operational features of large area 22 x 18 cm{sup 2} GEM foils. We present systematic studies of the stability of GEM foils under different operation conditions. These studies include measurements and calculations of the dynamic behavior of charges in the GEM foils after a trip. The results will be used to develop methods to avoid destructive discharges in the final readout module.

  15. Irradiation study on GEM IPC preamp/shaper

    International Nuclear Information System (INIS)

    Kandasamy, A.

    1995-01-01

    The Preamplifier/Shaper Integrated Circuit for the GEM Interpolating Pad Chamber (IPC), designed by Paul. O'Connor, Brookhaven National Laboratory is for amplifying the charge signal from the Pad cathodes into a voltage pulse which goes to the Analog Random Access Memory (ARAM) integrated circuit. The GEM IPC integrated circuit has a SemiGaussian voltage pulse output with a 30ns shaping time. The integrated circuits were fabricated using Harris Semiconductors AVLSI1-RA process in-order for the electronics on the wafer to survive up to 2 mad of ionizing radiation during its operation life time. The details of the electronics on the GEM IPC integrated circuits is explained in the design memorandum by Paul. O'Connor. The purpose of this study is to determine the ability of the electronics on this IC fabricated using the above process to withstand ionizing radiation up to the above mentioned dose level

  16. GEM applications outside high energy physics

    CERN Document Server

    Duarte Pinto, Serge

    2013-01-01

    From its invention in 1997, the Gas Electron Multiplier has been applied in nuclear and high energy physics experiments. Over time however, other applications have also exploited the favorable properties of GEMs. The use of GEMs in these applications will be explained in principle and practice. This paper reviews applications in research, beam instrumentation and homeland security. The detectors described measure neutral radiations such as photons, x-rays, gamma rays and neutrons, as well as all kinds of charged radiation. This paper provides an overview of the still expanding range of possibilities of this versatile detector concept.

  17. GEM-based gaseous photomultipliers for UV and visible photon imaging

    International Nuclear Information System (INIS)

    Moermann, D.; Balcerzyk, M.; Breskin, A.; Chechik, R.; Singh, B.K.; Buzulutskov, A.

    2003-01-01

    We present the current status of our research on GEM-based gaseous photomultipliers. Detectors combining multi-GEM electron multipliers with semi-transparent and reflective photocathodes are discussed. We present recent progress in extending the sensitivity of these detectors into the visible range. We demonstrate the long-term stability of an argon-sealed bi-alkali photo-diode and provide preliminary results of a gas-sealed Kapton-GEM detector with a bi-alkali photocathode. The problem of ion-induced secondary electron emission is addressed

  18. Gas electron multiplier (GEM) operation with tissue-equivalent gases at various pressures

    International Nuclear Information System (INIS)

    Farahmand, M.; Bos, A.J.J.; Eijk, C.W.E. van

    2003-01-01

    We have studied the operation of two different Gas Electron Multiplier (GEM) structures in both methane and propane based Tissue-Equivalent (TE) gases at different pressures varying from 0.1 to 1 atm. This work was motivated to explore the possibility of using a GEM for a new type of Tissue Equivalent Proportional Counter. In methane based TE gas, a maximum safe GEM gain of 1.5x10 3 has been reached while in propane based TE gas this is 6x10 3 . These maxima have been reached at different gas pressures depending on GEM structure and TE gas. Furthermore, we observed a decrease of the GEM gain in time before it becomes stable. Charge up/polarisation effects can explain this

  19. Fine-pitch glass GEM for high-resolution X-ray imaging

    International Nuclear Information System (INIS)

    Fujiwara, T.; Toyokawa, H.; Mitsuya, Y.

    2016-01-01

    We have developed a fine-pitch glass gas electron multiplier (G-GEM) for high-resolution X-ray imaging. The fine-pitch G-GEM is made of a 400 μm thick photo-etchable glass substrate with 150 μm pitch holes. It is fabricated using the same wet etching technique as that for the standard G-GEM. In this work, we present the experimental results obtained with a single fine-pitch G-GEM with a 50 × 50 mm 2 effective area. We recorded an energy resolution of 16.2% and gas gain up to 5,500 when the detector was irradiated with 5.9 keV X-rays. We present a 50 × 50 mm 2 X-ray radiograph image acquired with a scintillation gas and optical readout system.

  20. A Method for Estimating BeiDou Inter-frequency Satellite Clock Bias

    Directory of Open Access Journals (Sweden)

    LI Haojun

    2016-02-01

    Full Text Available A new method for estimating the BeiDou inter-frequency satellite clock bias is proposed, considering the shortage of the current methods. The constant and variable parts of the inter-frequency satellite clock bias are considered in the new method. The data from 10 observation stations are processed to validate the new method. The characterizations of the BeiDou inter-frequency satellite clock bias are also analyzed using the computed results. The results of the BeiDou inter-frequency satellite clock bias indicate that it is stable in the short term. The estimated BeiDou inter-frequency satellite clock bias results are molded. The model results show that the 10 parameters of model for each satellite can express the BeiDou inter-frequency satellite clock bias well and the accuracy reaches cm level. When the model parameters of the first day are used to compute the BeiDou inter-frequency satellite clock bias of the second day, the accuracy also reaches cm level. Based on the stability and modeling, a strategy for the BeiDou satellite clock service is presented to provide the reference of our BeiDou.

  1. Use of aluminium plates to simulate the dosimetry of gems during e-beam irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Fortes, Marcio Z.; Sousa, Fernando N.C. de; Boente, Otavio C., E-mail: mzamboti@aceletron.com.b, E-mail: fernando.nuno@aceletron.com.b, E-mail: otavio@aceletron.com.b [Aceletron Irradiacao Industrial, Rio de Janeiro, RJ (Brazil); Sousa, Nuno R.A., E-mail: engenheiro.nuno.sousa@gmail.co [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Dept. de Engenharia Mecanica

    2009-07-01

    The e-beam technology is used in the industrial irradiation of several products like turf, sterilization of medical products, cosmetics, polymers, food, and gems. More than 70% of the gems commercialized in the world receive treatments similar to those present in nature, including heat, and irradiation, in order to improve their value. Since aluminum has a density similar to that of several commercial gems, this paper presents a study of the penetration of electrons in calibrated aluminum plates simulating several different thicknesses ranging from 5 to 30 mm, and comparing with the one obtained in gems. This allows the monitoring of the dose received by gems during irradiation with e-beam systems measuring the delivered surface dose. This procedure is very important for industrial processing of stones due to the irregularities present on most gems, what makes dosimetry a very complex task. The determination of the thicknesses of the gems for which the surface dose is the lowest dose on the whole product assures the precise determination of the minimum dose received by the gems during industrial processing. (author)

  2. Evaluation of ozone profile and tropospheric ozone retrievals from GEMS and OMI spectra

    Directory of Open Access Journals (Sweden)

    J. Bak

    2013-02-01

    Full Text Available South Korea is planning to launch the GEMS (Geostationary Environment Monitoring Spectrometer instrument into the GeoKOMPSAT (Geostationary Korea Multi-Purpose SATellite platform in 2018 to monitor tropospheric air pollutants on an hourly basis over East Asia. GEMS will measure backscattered UV radiances covering the 300–500 nm wavelength range with a spectral resolution of 0.6 nm. The main objective of this study is to evaluate ozone profiles and stratospheric column ozone amounts retrieved from simulated GEMS measurements. Ozone Monitoring Instrument (OMI Level 1B radiances, which have the spectral range 270–500 nm at spectral resolution of 0.42–0.63 nm, are used to simulate the GEMS radiances. An optimal estimation-based ozone profile algorithm is used to retrieve ozone profiles from simulated GEMS radiances. Firstly, we compare the retrieval characteristics (including averaging kernels, degrees of freedom for signal, and retrieval error derived from the 270–330 nm (OMI and 300–330 nm (GEMS wavelength ranges. This comparison shows that the effect of not using measurements below 300 nm on retrieval characteristics in the troposphere is insignificant. However, the stratospheric ozone information in terms of DFS decreases greatly from OMI to GEMS, by a factor of ∼2. The number of the independent pieces of information available from GEMS measurements is estimated to 3 on average in the stratosphere, with associated retrieval errors of ~1% in stratospheric column ozone. The difference between OMI and GEMS retrieval characteristics is apparent for retrieving ozone layers above ~20 km, with a reduction in the sensitivity and an increase in the retrieval errors for GEMS. We further investigate whether GEMS can resolve the stratospheric ozone variation observed from high vertical resolution Earth Observing System (EOS Microwave Limb Sounder (MLS. The differences in stratospheric ozone profiles between GEMS and MLS are comparable to those

  3. M.C. simulation of GEM neutron beam monitor with 10B

    International Nuclear Information System (INIS)

    Wang Yanfeng; Sun Zhijia; Liu Ben; Zhou Jianrong; Yang Guian; Dong Jing; Xu Hong; Zhou Liang; Huang Guangming; Yang Lei; Li Yi

    2010-01-01

    The neutron beam monitor based on GEM detector has been carefully studied with the Monte-Carlo method in this article. The simulation framework is including the ANSYS and the Garfield, which was used to compute the electric field of GEM foils and simulate the movement of electrons in gas mixture respectively. The GEM foils' focus and extract coefficients have been obtained. According to the primary results, the performing of the monitor is improved. (authors)

  4. Continuous health monitoring of Graphite Epoxy Motorcases (GEM)

    Science.gov (United States)

    Finlayson, Richard D.; Schaafsma, David T.; Shen, H. Warren; Carlos, Mark F.; Miller, Ronnie K.; Shepherd, Brent

    2001-07-01

    Following the explosion of Delta 241 (IIR-1) on January 17th, 1997, the failure investigation board concluded that the Graphite Epoxy Motorcases (GEM's) should be inspected for damage just prior to launch. Subsequent investigations and feedback from industry led to an Aerospace Corporation proposal to instrument the entire fleet of GEM's with a continuous health monitoring system. The period of monitoring would extend from the initial acceptance testing through final erection on the launch pad. As this proposal demonstrates, (along with the increasing use of advanced composite materials in aircraft, automobiles, military hardware, and aerospace components such as rocket motorcases) a sizable need for composite health assessment measures exist. Particularly where continuous monitoring is required for the detection of damage from impacts and other sources of high mechanical and thermal stresses. Even low-momentum impacts can lead to barely visible impact damage (BVID), corresponding to a significant weakening of the composite. This damage, undetectable by visual inspection, can in turn lead to sudden and catastrophic failure when the material is subjected to a normal operating load. There is perhaps no system with as much potential for truly catastrophic failure as a rocket motor. We will present an update on our ongoing efforts with the United States Air Force Delta II Program Office, and The Aerospace Corporation. This will cover the development of a local, portable, surface-mounted, fiberoptic sensor based impact damage monitor designed to operate on a Delta II GEM during transport, storage, and handling. This system is designed to continuously monitor the GEMs, to communicate wirelessly with base stations and maintenance personnel, to operate autonomously for extended periods, and to fit unobtrusively on the GEM itself.

  5. Reactivity worth of gas expansion modules (GEMs) in the fast flux test facility

    International Nuclear Information System (INIS)

    Campbell, L.R.; Nelson, J.V.; Burke, T.M.; Rawlins, J.A.; Daughtry, J.W.; Bennett, R.A.

    1986-01-01

    A new passive shutdown device called a gas expansion module (GEM) has been developed at Hanford Engineering Development Laboratory to insert negative reactivity during a primary system loss of flow in a liquid-metal reactor (LMR). A GEM is a hollow removable core component which is sealed at the top and open at the bottom. An argon gas bubble trapped inside the assembly expands when core inlet pressure decreases (caused by a flow reduction) and expels sodium from the assembly. The GEMs are designed so that the level of the liquid-sodium primary system coolant within a GEM is above the top of the core when the primary pumps are operating at full flow and is below the bottom of the core when the primary pumps are off. When a GEM is placed at the boundary of the core and radial reflector, the drop in sodium level increases core neutron leakage and inserts negative reactivity. The results of these measurements confirm the effectiveness of GEMs in adding negative reactivity in loss-of-flow situations. It follows, therefore, that the inherent safety of LMRs, comparable in size to the FFTF, can be enhanced by the use of GEMs

  6. Development of single mask GEM foils in India

    International Nuclear Information System (INIS)

    Pant, L.M.; Mohanty, A.K.; Pinto, O.J.; Gadhadharan, S.; Menon, Pradeep; Sharma, Archana; Oliveira, Rui De; )

    2014-01-01

    There are various techniques available around the globe for making punch through holes for Micro Pattern Gas Detectors (MPGDs), such as Gas Electron Multipliers (GEMs). The GEM foils consists of 5 μm of Cu clad on both the sides of 50 μm polymide (PMMA/kapton) (5/50/5). At present these foils are developed in South Korea without having any adhesive between the Cu and polymide. The available techniques range from chemical etching, reactive plasma etching and laser etching. However, for GEM detectors, having an active area upto 5000 cm 2 , the chemical etching process using a Single Mask has been developed at CERN which is faster from the viewpoint of mass production of such foils for the upgrades which are foreseen in a couple of years with the Large Hadron Collider facility at CERN

  7. The current status of the Gas Electron Multiplier (GEM) research at Kasetsart University, Thailand

    Science.gov (United States)

    Kumpiranon, P.; Kulasri, K.; Rittirong, A.; Saenboonruang, K.

    2017-06-01

    During the past decade, Gas Electron Multiplier (GEM) detectors have been greatly developed and utilized in numbers of applications including advanced nuclear and particle researches, medical imaging, astrophysics, and neutron detection for national security. Our GEM research group at the Department of Applied Radiation and Isotopes, Faculty of Science, Kasetsart University, Thailand, realized in its excellent properties/potentials and started extensive researches on GEM detectors. To build a strong foundation on our research group, two 10 cm × 10 cm triple GEM detectors were characterized on their important properties including absolute gains and detection uniformity. Moreover, to widen applications of the GEM detector, our group had modified the GEM detector by introducing either solid or gaseous neutron converters to the detector so that the detector could effectively detect neutrons. These modifications included coating a thin film of 10B and natB to the GEM drift cathode for thermal neutron detection and flowing a gas mixture of He/CO2 (80:20 and 70:30) and C4H10/He/CO2 (7:70:23) for fast neutron detection. Results showed that the modified GEM-based neutron detector could detect both types of neutrons with different relative efficiencies and gains depending on thicknesses and types of neutron converters. This article discusses basic knowledge of the GEM detector, construction and testing procedures, results, and discussion.

  8. Portable XRF: A Tool for the Study of Corundum Gems

    Directory of Open Access Journals (Sweden)

    Barone Germana

    2017-09-01

    Full Text Available Origin of gemstones is a key aspect not only in gemological field but also in Cultural Heritage studies, for the correct evaluation of precious artifacts. The studies on gems require the application of non-invasive and non-destructive methods; among them, portable spectroscopic techniques has been demonstrated as powerful tools, providing a fingerprint of gems for origin and provenance determination. In this study, portable XRF spectroscopy has been applied to test the potential of the technique for the origin determination of corundum gems. The obtained results allowed distinguishing natural and synthetic rubies and sapphires.

  9. Graphics gems

    CERN Document Server

    Heckbert, Paul S

    1994-01-01

    Graphics Gems IV contains practical techniques for 2D and 3D modeling, animation, rendering, and image processing. The book presents articles on polygons and polyhedral; a mix of formulas, optimized algorithms, and tutorial information on the geometry of 2D, 3D, and n-D space; transformations; and parametric curves and surfaces. The text also includes articles on ray tracing; shading 3D models; and frame buffer techniques. Articles on image processing; algorithms for graphical layout; basic interpolation methods; and subroutine libraries for vector and matrix algebra are also demonstrated. Com

  10. Combined readout of a triple-GEM detector

    Science.gov (United States)

    Antochi, V. C.; Baracchini, E.; Cavoto, G.; Di Marco, E.; Marafini, M.; Mazzitelli, G.; Pinci, D.; Renga, F.; Tomassini, S.; Voena, C.

    2018-05-01

    Optical readout of GEM based devices by means of high granularity and low noise CMOS sensors allows to obtain very interesting tracking performance. Space resolution of the order of tens of μm were measured on the GEM plane along with an energy resolution of 20%÷30%. The main limitation of CMOS sensors is represented by their poor information about time structure of the event. In this paper, the use of a concurrent light readout by means of a suitable photomultiplier and the acquisition of the electric signal induced on the GEM electrode are exploited to provide the necessary timing informations. The analysis of the PMT waveform allows a 3D reconstruction of each single clusters with a resolution on z of 100 μm. Moreover, from the PMT signals it is possible to obtain a fast reconstruction of the energy released within the detector with a resolution of the order of 25% even in the tens of keV range useful, for example, for triggering purpose.

  11. GEM the gas electron multiplier

    CERN Document Server

    Sauli, Fabio

    1997-01-01

    We describe the basic structure and operation of a new device, the Gas Electron Multiplier. Consisting in a polymer foil, metal-clad on both sides and perforated by a high density of holes, the GEM mesh allows to pre-amplify charges released in the gas with good uniformity and energy. Coupled to a micro-strip plate, the pre-amplification element allows to preserve high rate capability and resolution at considerably lower operating voltages, thus completely eliminating discharges and instabilities. Several GEM grids can be operated in cascade; charge gains are large enough to allow detection of signals in the ionization mode on the last element, permitting the use of a simple printed circuit as read-out electrode. Two-dimensional read-out can then be easily implemented. A new generation of simple, reliable and cheap fast position sensitive detectors seems at hand.

  12. arXiv The new cylindrical GEM inner tracker of BESIII

    CERN Document Server

    Lavezzi, L.; Amoroso, A.; Ferroli, R. Baldini; Bertani, M.; Bettoni, D.; Bianchi, F.; Calcaterra, A.; Canale, N.; Capodiferro, M.; Carassiti, V.; Cerioni, S.; Chai, Jy; Chiozzi, S.; Cibinetto, G.; Cossio, F.; Cotta Ramusino, A.; De Mori, F.; Destefanis, M.; Dong, J.; Evangelisti, F.; Farinelli, R.; Fava, L.; Felici, G.; Fioravanti, E.; Garzia, I.; Gatta, M.; Greco, M.; Leng, Cy; Li, H.; Maggiora, M.; Malaguti, R.; Marcello, S.; Melchiorri, M.; Mezzadri, G.; Mignone, M.; Morello, G.; Pacetti, S.; Patteri, P.; Pellegrino, J.; Pelosi, A.; Rivetti, A.; Rolo,; Savrié, M.; Scodeggio, M.; Soldani, E.; Sosio, S.; Spataro, S.; Tskhadadze, E.; Verma, S.; Wheadon, R.; Yan, L.

    2018-05-03

    The Cylindrical GEM-Inner Tracker (CGEM-IT) is the upgrade of the internal tracking system of the BESIII experiment. It consists of three layers of cylindrically-shaped triple GEMs, with important innovations with respect to the existing GEM detectors, in order to achieve the best performance with the lowest material budget. It will be the first cylindrical GEM running with analog readout inside a 1T magnetic field. The simultaneous measurement of both the deposited charge and the signal time will permit to use a combination of two algorithms to evaluate the spatial position of the charged tracks inside the CGEM-IT: the charge centroid and the micro time projection chamber modes. They are complementary and can cope with the asymmetry of the electron avalanche when running in magnetic field and with non-orthogonal incident tracks. To evaluate the behaviour under different working settings, both planar chambers and the first cylindrical prototype have been tested during various test beams at CERN with 150 GeV/c...

  13. Innovative Development and Forecast of BeiDou System

    Directory of Open Access Journals (Sweden)

    TAN Shusen

    2017-10-01

    Full Text Available Due to the strong demand for satellite applications and rapid development of new space technology,the cross-integration of space-based radio systems has become a trend.BeiDou system started from two satellites to build China's first generation satellite navigation and positioning system with the features of fast location reporting(RDSSand short message communication(MSSservice.Then BeiDou technology frame combined with RNSS continuous navigation and RDSS location report,was constructed in eight years,and the coverage in Asia-Pacific was completed.Through effective satellite radio frequency compatible design and international coordination,BeiDou system is the first radio satellite system which includes RNSS,RDSS,MSS three major services,approved by International Telecommunication Union(ITUin the world.This paper expounds the development process,technical frame,main features and prospect of BeiDou system with three major services and four key functions,in the concept of innovation and transcendence.

  14. Positron emission tomography in urological cancer; Positronenemissionstomographie bei urologischen Tumoren

    Energy Technology Data Exchange (ETDEWEB)

    Wit, M. de [Universitaetskrankenhaus Eppendorf, Hamburg (Germany). Abt. Onkologie/Haematologie, Medizinische Klinik; Kotzerke, J. [Universitaetsklinikum Ulm (DE). Radiologie III (Nuklearmedizin)

    2000-09-01

    In staging cancer of the urinary bladder, the kidneys and the prostate and of testicular cancer there is a need for detecting tumor involvement of the lymph nodes to avoid surgical exploration. Positron emission tomography (PET) using fluorodeoxyglucose (FDG) can detect tumorous lymph nodes (sensitivity: 70%, specificity: 85%) which is helpful for several patients. In carcinoma of the prostate, other radiotracers than FDG (e.g. C-11-choline) might be more sensitive to detect tumorous lymph nodes. Up to now no diagnostical benefit of PET in germ cell tumors could be demonstrated in the published small series. In principle FDG-PET is useful in diagnosis of recurrence. In germ cell cancer FDG-PET seems to identify effectively persistent vital tumor tissue after chemotherapy. A multicenter study was initiated to demonstrate the potential of FDG-PET in a sufficient number of patients with germ cell tumor. (orig.) [German] Bei Harnblasen-, Nieren-, Prostata- und Hodenkarzinomen besteht aus klinischer Sicht ein Bedarf an verbessertem Lymphknoten-Staging, um die operative Evaluation zu vermeiden. Die Positronenemissionstomographie (PET) mit Fluordeoxyglukose (FDG) kann daher im Einzelfall bei Harnblasen- und Nierenkarzinomen hilfreich sein (bei Sensitivitaet um 70% und Spezifitaet um 85%). Beim Prostatakarzinom koennten sich andere Radiotracer (z.B. C-11-Cholin) bei der Detektion von tumoroesen Lymphknoten ueberlegen erweisen. Bei Keimzelltumoren konnte ein Nutzen der PET im primaeren Staging bei den bisher publizierten kleinen Studien nicht nachgewiesen werden. Fuer die Rezidivdiagnostik ist bei den genannten Tumoren aus grundsaetzlicher Ueberlegung der Einsatz von DFG-PET sinnvoll. Die Erkennung von vitalem malignen Tumorgewebe nach Chemotherapie erscheint bei Keimzelltumoren mit FDG-PET weitgehend sicher zu gelingen. Eine multizentrische Studie wurde begonnen, die hierueber Aufschluss geben wird. (orig.)

  15. Research of boron conversion coating in neutron detector with boron deposited GEM

    International Nuclear Information System (INIS)

    Ye Di; Sun Zhijia; Zhou Jianrong; Wang Yanfeng; Yang Guian; Xu Hong; Chen Yuanbai; Xiao Yu; Diao Xungang

    2014-01-01

    GEM is a flourishing new gas detector and nowadays its technology become more mature. It has outstanding properties, such as excellent position resolution, high counting rate, radiation resistance, simple and flexible signal readout, can be large-area detector, wide application range. Detector with boron deposited GEM uses multilayer GEM with deposited boron film as neutron conversion carrier which reads out the information of neutron shot from the readout electrode with gas amplification from every GEM layer. The detector is high performance which can meet the demands of neutron detector of a new generation. Boron deposited neutron conversion electrode with boron deposited cathode and GEM included is the core part of the detector. As boron is a high-melting-point metalloid (> 2 000 ℃), electroplating and thermal evaporation are inappropriate ways. So finding a way to deposit boron on electrode which can meet the demands become a key technology in the development of neutron detector with boron deposited GEM. Compared with evaporation, sputtering has features such as low deposition temperature, high film purity, nice adhesive, thus is appropriate for our research. Magnetron sputtering is a improved way of sputtering which can get lower sputtering air pressure and higher target voltage, so that we can get better films. Through deposit process, the research uses magnetron sputtering to deposit pure boron film on copper electrode and GEM film. This method can get high quality, nice adhere, high purity, controllable uniformity, low cost film with high speed film formation. (authors)

  16. Performance of an optical readout GEM-based TPC

    International Nuclear Information System (INIS)

    Margato, L.M.S.; Fraga, F.A.F.; Fetal, S.T.G.; Fraga, M.M.F.R.; Balau, E.F.S.; Blanco, A.; Marques, R. Ferreira; Policarpo, A.J.P.L

    2004-01-01

    We report on the operation of a GEM-based small TPC using an optical readout. The detector was operated with a mixture of Ar+CF 4 using 5.48 MeV alpha particles obtained from a 241 Am source and the GEM scintillation was concurrently read by a CCD camera and a photomultiplier. Precision collimators were used to define the track orientation. Qualitative results on the accuracy of the track angle, length and charge deposition measurements are presented

  17. Gaseous elemental mercury (GEM emissions from snow surfaces in northern New York.

    Directory of Open Access Journals (Sweden)

    J Alexander Maxwell

    Full Text Available Snow surface-to-air exchange of gaseous elemental mercury (GEM was measured using a modified Teflon fluorinated ethylene propylene (FEP dynamic flux chamber (DFC in a remote, open site in Potsdam, New York. Sampling was conducted during the winter months of 2011. The inlet and outlet of the DFC were coupled with a Tekran Model 2537A mercury (Hg vapor analyzer using a Tekran Model 1110 two port synchronized sampler. The surface GEM flux ranged from -4.47 ng m(-2 hr(-1 to 9.89 ng m(-2 hr(-1. For most sample periods, daytime GEM flux was strongly correlated with solar radiation. The average nighttime GEM flux was slightly negative and was not well correlated with any of the measured meteorological variables. Preliminary, empirical models were developed to estimate GEM emissions from snow surfaces in northern New York. These models suggest that most, if not all, of the Hg deposited with and to snow is reemitted to the atmosphere.

  18. Gaseous elemental mercury (GEM) emissions from snow surfaces in northern New York.

    Science.gov (United States)

    Maxwell, J Alexander; Holsen, Thomas M; Mondal, Sumona

    2013-01-01

    Snow surface-to-air exchange of gaseous elemental mercury (GEM) was measured using a modified Teflon fluorinated ethylene propylene (FEP) dynamic flux chamber (DFC) in a remote, open site in Potsdam, New York. Sampling was conducted during the winter months of 2011. The inlet and outlet of the DFC were coupled with a Tekran Model 2537A mercury (Hg) vapor analyzer using a Tekran Model 1110 two port synchronized sampler. The surface GEM flux ranged from -4.47 ng m(-2) hr(-1) to 9.89 ng m(-2) hr(-1). For most sample periods, daytime GEM flux was strongly correlated with solar radiation. The average nighttime GEM flux was slightly negative and was not well correlated with any of the measured meteorological variables. Preliminary, empirical models were developed to estimate GEM emissions from snow surfaces in northern New York. These models suggest that most, if not all, of the Hg deposited with and to snow is reemitted to the atmosphere.

  19. GEM Foil Quality Assurance For The ALICE TPC Upgrade

    Science.gov (United States)

    Brücken, Erik; Hildén, Timo

    2018-02-01

    The ALICE (A Large Ion Collider Experiment) experiment at the Large Hadron Collider (LHC) at CERN is dedicated to heavy ion physics to explore the structure of strongly interacting matter. The Time Projection Chamber (TPC) of ALICE is a tracking detector located in the central region of the experiment. It offers excellent tracking capabilities as well as particle identification. After the second long shutdown (LS2) the LHC will run at substantially higher luminosities. To be able to increase the data acquisition rate by a factor of 100, the ALICE TPC experiment has to replace the Multi-Wire Proportional Chamber (MWPC) -based readout chambers. The MWPC are operated with gating grid that limits the rate to O(kHz). The new ReadOut Chamber (ROC) design is based on Gas Electron Multiplier (GEM) technology operating in continuous mode. The current GEM productions scheme foresees the production of more than 800 GEM foils of different types. To fulfill the requirements on the performance of the GEM TPC readout, necessitates thorough Quality Assurance (QA) measures. The QA scheme, developed by the ALICE collaboration, will be presented in detail.

  20. GEM Foil Quality Assurance For The ALICE TPC Upgrade

    Directory of Open Access Journals (Sweden)

    Brücken Erik

    2018-01-01

    Full Text Available The ALICE (A Large Ion Collider Experiment experiment at the Large Hadron Collider (LHC at CERN is dedicated to heavy ion physics to explore the structure of strongly interacting matter. The Time Projection Chamber (TPC of ALICE is a tracking detector located in the central region of the experiment. It offers excellent tracking capabilities as well as particle identification. After the second long shutdown (LS2 the LHC will run at substantially higher luminosities. To be able to increase the data acquisition rate by a factor of 100, the ALICE TPC experiment has to replace the Multi-Wire Proportional Chamber (MWPC –based readout chambers. The MWPC are operated with gating grid that limits the rate to O(kHz. The new ReadOut Chamber (ROC design is based on Gas Electron Multiplier (GEM technology operating in continuous mode. The current GEM productions scheme foresees the production of more than 800 GEM foils of different types. To fulfill the requirements on the performance of the GEM TPC readout, necessitates thorough Quality Assurance (QA measures. The QA scheme, developed by the ALICE collaboration, will be presented in detail.

  1. High voltage distribution scheme for large size GEM detector

    International Nuclear Information System (INIS)

    Saini, J.; Kumar, A.; Dubey, A.K.; Negi, V.S.; Chattopadhyay, S.

    2016-01-01

    Gas Electron Multiplier (GEM) detectors will be used for Muon tracking in the Compressed Baryonic Matter (CBM) experiment at the Facility for Anti-proton Ion Research (FAIR) at Darmstadt, Germany. The sizes of the detector modules in the Muon chambers are of the order of 1 metre x 0.5 metre. For construction of these chambers, three GEM foils are used per chamber. These foils are made by two layered 50μm thin kapton foil. Each GEM foil has millions of holes on it. In such a large scale manufacturing of the foils, even after stringent quality controls, some of the holes may still have defects or defects might develop over the time with operating conditions. These defects may result in short-circuit of the entire GEM foil. A short even in a single hole will make entire foil un-usable. To reduce such occurrences, high voltage (HV) segmentation within the foils has been introduced. These segments are powered either by individual HV supply per segment or through an active HV distribution to manage such a large number of segments across the foil. Individual supplies apart from being costly, are highly complex to implement. Additionally, CBM will have high intensity of particles bombarding on the detector causing the change of resistive chain current feeding the GEM detector with the variation in the intensity. This leads to voltage fluctuations across the foil resulting in the gain variation with the particle intensity. Hence, a low cost active HV distribution is designed to take care of the above discussed issues

  2. Performance Evaluation of the COBRA GEM for the Application of the TPC

    Science.gov (United States)

    Terasaki, Kohei; Hamagaki, Hideki; Gunji, Taku; Yamaguchi, Yorito

    2014-09-01

    Suppression of the back-drifting ions from avalanche region to drift space (IBF: Ion Backflow) is the key for a Time Projection Chamber (TPC) since IBF easily distorts the drift field. To suppress IBF, Gating Grid system is widely used for the TPC but this limits the data taking rate. Gas Electron Multiplier (GEM) has advantages in the reduction of IBF and high rate capability. By adopting GEM, it is possible to run a TPC continuously under high rate and high multiplicity conditions. Motivated by the study of IBF reduction for RICH with Thick COBRA, which has been developed by F. A. Amero et al., we developed COBRA GEMs for the application of a TPC. With a stack configuration, IBF reaches about 0.1 ~ 0.5%, which is ×5--10 better IBF than the standard GEMs. However, the measured energy resolution with COBRA is 20% (σ) and this is much worse than the resolution with standard GEMs. Measurement of long-time stability of gain indicates that gain of COBRA varies significantly due to charging up effect. Simulation studies based on Garfield++ are performed for understanding quantitatively the reasons of worse energy resolution and instability of gain. In this presentation, we will report the simulation studies together with the measured performance of the COBRA GEM.

  3. Experiment study on the thick GEM-like multiplier for X-ray photoelectrons energy deposition gaining

    International Nuclear Information System (INIS)

    Zhu Pengfei; Ye Yan; Long Yan; Cao Ningxiang; Jia Xing; Li Jianfeng

    2009-01-01

    The GEM is a novel detector with high gain,high time and location resolution. Imitating the structure of the GEM, a thick GEM-like multiplier which has the similar function with that of the GEM is designed and manufactured. The characteristics of the thick GEM-like multiplier increasing electron energy deposition in absorbing medium has been experimentally studied. The results indicate that the energy deposition gain of x-ray photoelectron in medium is apparent, and the maximum energy deposition can increase by more than 40%. Some suggestions of further increasing the energy deposition are given, and the future application of the way of increasing the x-ray photoelectron energy deposition by the thick GEM-like multiplier in hard x-ray imaging is prospected. (authors)

  4. Experimental and Theoretical Progress on the GEM Theory

    Science.gov (United States)

    Brandenburg, J. E.

    This paper reports experimental and theoretical progress on the GEM unification theory. In theoretical progress, the derivation of the GEM theory using it in a fully covariant form is achieved based on the principle of self-cancellation of the ZPF EM stress-momentum tensor. This derivation reveals that the final Gravity-EM system obeys a Helmholtz-like equation resembling that governing sound propagation. Finally an improved derivation of the formula for the Newton Gravitation constant is shown, qresulting in the formula G = e2/(4πɛ0 me mp) α exp (-2 (α-.86/σ2…) = 6.673443 x10-11 N-m2 kg-2 that agrees with experimental values to 3 parts per 100,000. Experiments have found parity violating weight reductions in gyroscopes driven by rotating EM fields. These experiments appear to confirm gravity modification using electromagnetism predicted by the GEM theory through the Vacuum Bernoulli Equation.

  5. Gender Evaluation Methodology (GEM) | IDRC - International ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    2011-10-28

    Oct 28, 2011 ... For more resources and access to the GEM Practitioners Network, ... Home · Resources · Publications ... The Association for Progressive Communications Women's Networking Support Programme (APC WNSP) developed ...

  6. Initial assessment of the COMPASS/BeiDou-3: new-generation navigation signals

    Science.gov (United States)

    Zhang, Xiaohong; Wu, Mingkui; Liu, Wanke; Li, Xingxing; Yu, Shun; Lu, Cuixian; Wickert, Jens

    2017-10-01

    The successful launch of five new-generation experimental satellites of the China's BeiDou Navigation Satellite System, namely BeiDou I1-S, I2-S, M1-S, M2-S, and M3-S, marks a significant step in expanding BeiDou into a navigation system with global coverage. In addition to B1I (1561.098 MHz) and B3I (1269.520 MHz) signals, the new-generation BeiDou-3 experimental satellites are also capable of transmitting several new navigation signals in space, namely B1C at 1575.42 MHz, B2a at 1176.45 MHz, and B2b at 1207.14 MHz. For the first time, we present an initial characterization and performance assessment for these new-generation BeiDou-3 satellites and their signals. The L1/L2/L5 signals from GPS Block IIF satellites, E1/E5a/E5b signals from Galileo satellites, and B1I/B2I/B3I signals from BeiDou-2 satellites are also evaluated for comparison. The characteristics of the B1C, B1I, B2a, B2b, and B3I signals are evaluated in terms of observed carrier-to-noise density ratio, pseudorange multipath and noise, triple-frequency carrier-phase ionosphere-free and geometry-free combination, and double-differenced carrier-phase and code residuals. The results demonstrate that the observational quality of the new-generation BeiDou-3 signals is comparable to that of GPS L1/L2/L5 and Galileo E1/E5a/E5b signals. However, the analysis of code multipath shows that the elevation-dependent code biases, which have been previously identified to exist in the code observations of the BeiDou-2 satellites, seem to be not obvious for all the available signals of the new-generation BeiDou-3 satellites. This will significantly benefit precise applications that resolve wide-lane ambiguity based on Hatch-Melbourne-Wübbena linear combinations and other applications such as single-frequency precise point positioning (PPP) based on the ionosphere-free code-carrier combinations. Furthermore, with regard to the triple-frequency carrier-phase ionosphere-free and geometry-free combination, it is found

  7. Wirksamkeit der Hypnose auf Schmerzen bei Erwachsenen: systematische Literaturreview

    OpenAIRE

    Pfaffen, Céline; Z`Brun-Schnyder, Silvia

    2018-01-01

    Das Ziel dieser systematischen Literaturreview ist es, die Wirksamkeit der Hypnose auf Schmerzen bei Erwachsenen zu überprüfen. Daraus ergibt sich folgende Forschungsfrage: "Wie wird die Wirksamkeit der Hypnose auf Schmerzen bei Erwachsenen in der wissenschaftlichen Literatur beschrieben?"

  8. FPGA-based GEM detector signal acquisition for SXR spectroscopy system

    Science.gov (United States)

    Wojenski, A.; Pozniak, K. T.; Kasprowicz, G.; Kolasinski, P.; Krawczyk, R.; Zabolotny, W.; Chernyshova, M.; Czarski, T.; Malinowski, K.

    2016-11-01

    The presented work is related to the Gas Electron Multiplier (GEM) detector soft X-ray spectroscopy system for tokamak applications. The used GEM detector has one-dimensional, 128 channel readout structure. The channels are connected to the radiation-hard electronics with configurable analog stage and fast ADCs, supporting speeds of 125 MSPS for each channel. The digitalized data is sent directly to the FPGAs using fast serial links. The preprocessing algorithms are implemented in the FPGAs, with the data buffering made in the on-board 2Gb DDR3 memory chips. After the algorithmic stage, the data is sent to the Intel Xeon-based PC for further postprocessing using PCI-Express link Gen 2. For connection of multiple FPGAs, PCI-Express switch 8-to-1 was designed. The whole system can support up to 2048 analog channels. The scope of the work is an FPGA-based implementation of the recorder of the raw signal from GEM detector. Since the system will work in a very challenging environment (neutron radiation, intense electro-magnetic fields), the registered signals from the GEM detector can be corrupted. In the case of the very intense hot plasma radiation (e.g. laser generated plasma), the registered signals can overlap. Therefore, it is valuable to register the raw signals from the GEM detector with high number of events during soft X-ray radiation. The signal analysis will have the direct impact on the implementation of photon energy computation algorithms. As the result, the system will produce energy spectra and topological distribution of soft X-ray radiation. The advanced software was developed in order to perform complex system startup and monitoring of hardware units. Using the array of two one-dimensional GEM detectors it will be possible to perform tomographic reconstruction of plasma impurities radiation in the SXR region.

  9. Formation of GEMS from shock-accelerated crystalline dust in Superbubbles

    International Nuclear Information System (INIS)

    Westphal, A; Bradley, J P

    2004-01-01

    Interplanetary dust particles (IDPs) contain enigmatic sub-micron components called GEMS (Glass with Embedded Metal and Sulfides). The compositions and structures of GEMS indicate that they have been processed by exposure to ionizing radiation but details of the actual irradiation environment(s) have remained elusive. Here we propose a mechanism and astrophysical site for GEMS formation that explains for the first time the following key properties of GEMS; they are stoichiometrically enriched in oxygen and systematically depleted in S, Mg, Ca and Fe (relative to solar abundances), most have normal (solar) oxygen isotopic compositions, they exhibit a strikingly narrow size distribution (0.1-0.5 (micro)m diameter), and some of them contain ''relict'' crystals within their silicate glass matrices. We show that the compositions, size distribution, and survival of relict crystals are inconsistent with amorphization by particles accelerated by diffusive shock acceleration. Instead, we propose that GEMS are formed from crystalline grains that condense in stellar outflows from massive stars in OB associations, are accelerated in encounters with frequent supernova shocks inside the associated superbubble, and are implanted with atoms from the hot gas in the SB interior. We thus reverse the usual roles of target and projectile. Rather than being bombarded at rest by energetic ions, grains are accelerated and bombarded by a nearly monovelocity beam of atoms as viewed in their rest frame. Meyer, Drury and Ellison have proposed that galactic cosmic rays originate from ions sputtered from such accelerated dust grains. We suggest that GEMS are surviving members of a population of fast grains that constitute the long-sought source material for galactic cosmic rays. Thus, representatives of the GCR source material may have been awaiting discovery in cosmic dust labs for the last thirty years

  10. A large ungated TPC with GEM amplification

    Science.gov (United States)

    Berger, M.; Ball, M.; Fabbietti, L.; Ketzer, B.; Arora, R.; Beck, R.; Böhmer, F. V.; Chen, J.-C.; Cusanno, F.; Dørheim, S.; García, F.; Hehner, J.; Herrmann, N.; Höppner, C.; Kaiser, D.; Kis̆, M.; Kleipa, V.; Konorov, I.; Kunkel, J.; Kurz, N.; Leifels, Y.; Müllner, P.; Münzer, R.; Neubert, S.; Rauch, J.; Schmidt, C. J.; Schmitz, R.; Soyk, D.; Vandenbroucke, M.; Voss, B.; Walther, D.; Zmeskal, J.

    2017-10-01

    A Time Projection Chamber (TPC) is an ideal device for the detection of charged particle tracks in a large volume covering a solid angle of almost 4 π. The high density of hits on a given particle track facilitates the task of pattern recognition in a high-occupancy environment and in addition provides particle identification by measuring the specific energy loss for each track. For these reasons, TPCs with Multiwire Proportional Chamber (MWPC) amplification have been and are widely used in experiments recording heavy-ion collisions. A significant drawback, however, is the large dead time of the order of 1 ms per event generated by the use of a gating grid, which is mandatory to prevent ions created in the amplification region from drifting back into the drift volume, where they would severely distort the drift path of subsequent tracks. For experiments with higher event rates this concept of a conventional TPC operating with a triggered gating grid can therefore not be applied without a significant loss of data. A continuous readout of the signals is the more appropriate way of operation. This, however, constitutes a change of paradigm with considerable challenges to be met concerning the amplification region, the design and bandwidth of the readout electronics, and the data handling. A mandatory prerequisite for such an operation is a sufficiently good suppression of the ion backflow from the avalanche region, which otherwise limits the tracking and particle identification capabilities of such a detector. Gas Electron Multipliers (GEM) are a promising candidate to combine excellent spatial resolution with an intrinsic suppression of ions. In this paper we describe the design, construction and the commissioning of a large TPC with GEM amplification and without gating grid (GEM-TPC). The design requirements have driven innovations in the construction of a light-weight field-cage, a supporting media flange, the GEM amplification and the readout system, which are

  11. Design of large size segmented GEM foils and Drift PCB for CBM MUCH

    International Nuclear Information System (INIS)

    Saini, J.; Dubey, A.K.; Chattopadhyay, S.

    2016-01-01

    Triple GEM (Gas Electron Multiplier), sector shaped detectors will be used for Muon tracking in the Compressed Baryonic Matter (CBM) experiment at Anti-proton Ion Research (FAIR) facility at Darmstadt, Germany. The sizes of the detectors modules in the Muon Chambers (MUCH) are of the order of 1 meter with active area of about 75cms. Progressive pad geometry is chosen for the readout from these detectors. In construction of these chambers, three GEM foils are stacked on top of each other in a 3/2/2/2 gap configuration. The GEM foils are double layered copper clad 50μm thin Kapton foil. Each GEM foil has millions of holes on it. Foils of large surface area are prone to damages due to discharges owing to the high capacitance of the foil. Hence, these foils have their top surfaces divided into segments of about 100 sq.cm. Further segmentation may be necessary when there are high rate requirements, as in the case of CBM. For the GEM foils of CBM MUCH, a 24 segment layout has been adopted. Short-circuit in any of the GEM-holes will make entire foil un-usable. To reduce such occurrences, segment to segment isolation using opto-coupler in series with the GEM-foil segments has been introduced. Hence, a novel design for GEM chamber drift-PCB and foils has been made. In this scheme, each segment is powered and controlled individually. At the same time, the design takes into account, the space constraints, not only in x-y plane, but also in the z, due to compact assembly of MUCH detector layers

  12. The Gravity and Extreme Magnetism Small Explorer (GEMS)

    Science.gov (United States)

    Kallman, T. R.

    2011-01-01

    The Gravity and Extreme Magnetism Small Explorer (GEMS) was selected by NASA for flight in 2014 to make a sensitive search for X-ray polarization from a wide set of source classes, including stellar black holes, Seyfert galaxies and quasars, blazars, rotation and accretion-powered pulsars, magnetars, shell supernova remnants and pulsar wind nebulae. Among the primary scientific objectives are determining the effects of the spin of black holes and the geometry of supermassive black hole accretion, determining the configurations of the magnetic fields and the X-ray emission of magnetars, and determining the magnetic structure of the supernova shocks in which cosmic rays are accelerated. GEMS will observe 23 targets during a 16 month prime mission, in observations that will be able to reach predicted levels of polarization. The mission can be extended to provide a guest observer phase. The GEMS instrument has time projection chamber polarimeters with high 2-10 keV efficiency at the focus of thin foil mirrors. The 4.5 m focal length mirrors will be deployed on an extended boom. The spacecraft with the instrument is rotated with a period of about 10 minutes to enable measurement and correction of systematic errors. A small Bragg reflection soft X-ray experiment takes advantage of this rotation to obtain a measurement at 0.5 keV. The design of the GEMS instrument and the mission, the expected performance and the planned science program will be discussed.

  13. Study on Physical Properties and Chemical Composition of Some Myanmar Gems

    International Nuclear Information System (INIS)

    Kyaw Myint Htoo; Tun Khin; Sein Htoon

    2004-05-01

    Physical properties of some Myanmar gems were studied by using refractometer, dichroscope, polariscope, SG test, UV test and microscope. Then, chemical composition were investigated by XRF-technique. After that, gem identification, evaluation, colour improvement were studied according to these physical properties and chemical composition

  14. Synthesis and Biological Evaluation of Glycosidase Inhibitors: gem-Difluoromethylenated Nojirimycin Analogues

    DEFF Research Database (Denmark)

    Bols, Mikael; Wang, Ruo-Wen; Qiu, Xiao-Long

    2006-01-01

    In our ongoing program aimed at the design, synthesis, and biological evaluation of novel gem-difluoromethylenated glycosidase inhibitors, gem-4,4-difluoromethylenated iminosugars (5-9) were synthesized. The biological evaluation of these synthetic iminosugars showed that the gem....... It is proposed that the unprotonated iminosugar is the species preferably bound by beta-glucosidase, due to the lower pK(a) value of iminosugar 6 than of 1 or 36, leaving iminosugars 1 and 36 mostly protonated at pH 5.0, while iminosugar 6 is not. Iminosugar 6 also displayed good and selective inhibition of beta...

  15. The cylindrical GEM detector of the KLOE-2 experiment

    International Nuclear Information System (INIS)

    Bencivenni, G.; Ciambrone, P.; De Lucia, E.; Domenici, D.; Felici, G.; Fermani, P.; Morello, G.; Branchini, P.; Cicco, A. Di; Czerwinski, E.

    2017-01-01

    The KLOE-2 experiment started its data taking campaign in November 2014 with an upgraded tracking system at the DAΦNE electron-positron collider at the Frascati National Laboratory of INFN. The new tracking device, the Inner Tracker, operated together with the KLOE-2 Drift Chamber, has been installed to improve track and vertex reconstruction capabilities of the experimental apparatus. The Inner Tracker is a cylindrical GEM detector composed of four cylindrical triple-GEM detectors, each provided with an X-V strips-pads stereo readout. Although GEM detectors are already used in high energy physics experiments, this device is considered a frontier detector due to its fully-cylindrical geometry: KLOE-2 is the first experiment benefiting of this novel detector technology. Alignment and calibration of this detector will be presented together with its operating performance and reconstruction capabilities.

  16. CMS GEM detector material study for the HL-LHC

    CERN Document Server

    Muhammad, Saleh

    2017-01-01

    A study on the Gaseous Electron Multiplier (GEM) foil material is performed to determine the moisture diffusion rate and saturation level and the moisture effects on its mechanical properties. The study is focused on the foil contact with ambient air and moisture to determine the value of the diffusion coefficient of water in the detector polyimide. The presence of water inside the detector foil can determine the changes in its mechanical and electrical properties. A simulated model is developed by taking into account the real GEM foil (hole dimensions, shapes and material), which describes the adsorption on a sample. This work describes the model, its experimental verification, the water diffusion within the entire sheet geometry of the GEM foil, thus gaining concentration profiles and the time required to saturate the system and the effects on the mechanical properties.

  17. Gemcitabine-loaded albumin nanospheres (GEM-ANPs) inhibit PANC-1 cells in vitro and in vivo

    Science.gov (United States)

    Li, Ji; Di, Yang; Jin, Chen; Fu, Deliang; Yang, Feng; Jiang, Yongjian; Yao, Lie; Hao, Sijie; Wang, Xiaoyi; Subedi, Sabin; Ni, Quanxing

    2013-04-01

    With the development of nanotechnology, special attention has been given to the nanomaterial application in tumor treatment. Here, a modified desolvation-cross-linking method was successfully applied to fabricate gemcitabine-loaded albumin nanospheres (GEM-ANPs), with 110 and 406 nm of mean diameter, respectively. The aim of this study was to assess the drug distribution, side effects, and antitumor activity of GEM-ANPs in vivo. The metabolic viability and flow cytometry analysis revealed that both GEM-ANPs, especially 406-nm GEM-ANPs, could effectively inhibit the metabolism and proliferation and promote the apoptosis of human pancreatic carcinoma (PANC-1) in vitro. Intravenous injection of 406-nm GEM-ANPs exhibited a significant increase of gemcitabine in the pancreas, liver, and spleen of Sprague-Dawley rats ( p PANC-1-induced tumor mice, intravenous injection of 406-nm GEM-ANPs also could effectively reduce the tumor volume by comparison with free gemcitabine. With these findings, albumin nanosphere-loading approach might be efficacious to improve the antitumor activity of gemcitabine, and the efficacy is associated with the size of GEM-ANPs.

  18. Measurement of CP-violation with the GEM detector

    International Nuclear Information System (INIS)

    Yamamoto, Hiroaki

    1993-01-01

    In this note, the feasibility of measuring CP-violation in the B-meson system with the GEM detector at SSC is described, using the decay mode B d → J/ψ + K 0 S → μ + μ - π + π - for the β angle measurement. In Section 2, the signature of the signal is discussed. Section 3 is devoted to a description of the GEM performance, including the estimation of the backgrounds. The rate of the signal is discussed in Section 4, and the summary is given in Section 5

  19. Investigations on Important Properties of the 10 cm x 10 cm GEM Prototype

    CERN Document Server

    Saenboonruang, Kiadtisak; Kulasri, Kittipong; Ritthirong, Anawat

    2015-01-01

    The Gas Electron Multiplier (GEM) detector is one of promising particle and radiation detectors that has been improved greatly from previous gas detectors. The improvement includes better spatial resolutions, higher detection rate capabilities, and flexibilities in designs. In particular, the 10 cm x 10 cm GEM prototype is designed and provided by the Gas Detectors Development group (GDD) at CERN, Switzerland. With its simplicity in operations and designs, while still maintaining high qualities, the GEM prototype is suitable for both start-up and advanced researches. This article aims to report the investigations on some important properties of the 10 cm x 10 cm GEM detector using current measurement and signal counting. Results have shown that gains of the GEM prototype exponentially increase as voltage supplied to the detector increases, while the detector reaches full efficiency (plateau region) when the voltage is greater than 4100 V. In terms of signal sharing between X and Y strips of the readout, X str...

  20. The GEM-Mars general circulation model for Mars: Description and evaluation

    Science.gov (United States)

    Neary, L.; Daerden, F.

    2018-01-01

    GEM-Mars is a gridpoint-based three-dimensional general circulation model (GCM) of the Mars atmosphere extending from the surface to approximately 150 km based on the GEM (Global Environmental Multiscale) model, part of the operational weather forecasting and data assimilation system for Canada. After the initial modification for Mars, the model has undergone considerable changes. GEM-Mars is now based on GEM 4.2.0 and many physical parameterizations have been added for Mars-specific atmospheric processes and surface-atmosphere exchange. The model simulates interactive carbon dioxide-, dust-, water- and atmospheric chemistry cycles. Dust and water ice clouds are radiatively active. Size distributed dust is lifted by saltation and dust devils. The model includes 16 chemical species (CO2, Argon, N2, O2, CO, H2O, CH4, O3, O(1D), O, H, H2, OH, HO2, H2O2 and O2(a1Δg)) and has fully interactive photochemistry (15 reactions) and gas-phase chemistry (31 reactions). GEM-Mars provides a good simulation of the water and ozone cycles. A variety of other passive tracers can be included for dedicated studies, such as the emission of methane. The model has both a hydrostatic and non-hydrostatic formulation, and together with a flexible grid definition provides a single platform for simulations on a variety of horizontal scales. The model code is fully parallelized using OMP and MPI. Model results are evaluated by comparison to a selection of observations from instruments on the surface and in orbit, relating to atmosphere and surface temperature and pressure, dust and ice content, polar ice mass, polar argon, and global water and ozone vertical columns. GEM-Mars will play an integral part in the analysis and interpretation of data that is received by the NOMAD spectrometer on the ESA-Roskosmos ExoMars Trace Gas Orbiter. The present paper provides an overview of the current status and capabilities of the GEM-Mars model and lays the foundations for more in-depth studies in support

  1. Study of relevant parameters of GEM-based detectors

    CERN Document Server

    Croci, Gabriele; Sauli, Fabio; Ragazzi, S

    2007-01-01

    The Gas Electron Multiplier consist of a thin Kapton insulating (50 $\\mu$m) foil copper-clad on both sides and perforated by a high density, regular matrix of holes (around 100 per square millimeter). Typically the distance between holes (pitch) is 140 $\\mu$m and diameters of about 70 $\\mu$m. The mesh is realised by conventional photolitographic methods as used for the fabrication of multi-layer board. Upon application of a potential difference between the GEM electrodes, a high dipole field develops in the holes focusing the field lines between the drift electrode and the readout element. Electron drift along the channel and the charge is amplified by a factor that depends on the field density and the length of the channel. Owing to their excellent position resolution and rate capability GEM-based detector are very suitable to be used in different applications: from the high energy physics to the medical field. The GEM temporal and rate gain stability was studied and it was discovered that the gain variation...

  2. Entwicklungstrends bei landwirtschaftlichen Applikationen - ein Zwischenfazit

    Directory of Open Access Journals (Sweden)

    Christa Hoffmann

    2014-10-01

    Full Text Available Globalisierung, volatile Märkte und der vermehrte Rückzug der Agrarpolitik aus der Marktregulierung sorgen dafür, dass die Entscheidungsfindungsprozesse auf landwirtschaftlichen Betrieben an Komplexität zunehmen. Applikationen bieten durch ihre Mobilität und individuellen Ausgestaltungsmöglichkeiten Optionen, um den Landwirt bei seiner täglichen Arbeit zu unterstützen. In diesem Kontext nimmt diese Arbeit eine Bestandsaufnahme und Kategorisierung nativer Applikationen mit landwirtschaftlichem Bezug vor. Die Ergebnisse zeigen unter anderem einen Angebotsschwerpunkt im Produktionszweig Pflanzenbau und bei den Funktionen bestimmte häufig auftretende bedarfsbedingte Kombinationen (z. B. Planung und Analyse.

  3. Knochenstoffwechsel bei malignen Erkrankungen

    Directory of Open Access Journals (Sweden)

    Keck A-V

    2003-01-01

    Full Text Available Bei malignen Erkrankungen, wie dem Mammakarzinom, dem Prostatakarzinom, dem Bronchialkarzinom oder dem multiplen Myelom ist der Knochen eines der am häufigsten von Metastasen betroffenen Organe. Das klinische Beschwerdebild ist durch das Auftreten pathologischer Frakturen, Schmerzen und Hyperkalzämien gekennzeichnet. Eine erhöhte Knochenresorptionsrate und Verlust an Knochenmasse im Sinne von osteoporoseartigen Veränderungen bedingt durch eine inadäquat überschießende Osteoklastendifferenzierung und -aktivierung sind ursächlich dafür verantwortlich. Durch jüngst publizierte Ergebnisse diverser Studien und Untersuchungen konnten die genauen Mechanismen der Rekrutierung und Aktivierung von Osteoklasten weiter aufgeklärt werden. Receptor activator of nuclear factor-kappa-B ligand (RANKL, ein Mitglied der Tumor necrosis factor (TNF Superfamilie konnte als entscheidender Faktor in der Osteoklastengenese identifiziert werden. Die Interaktion von RANKL mit seinem Rezeptor RANK (receptor activator of nuclear factor-kappa-B induziert die Entwicklung der osteoklastären Reihe aus dem hämatopoetischen Kompartment und fördert weiters die Differenzierung zu Osteoklastenvorstufen und die Aktivierung reifer Osteoklasten, ebenso wird eine verzögert einsetzende Apoptose bewirkt. Neben RANK und RANKL ist Osteoprotegerin (OPG als dritte Komponente in der Regulation der Knochenresorption involviert. Als Mitglied der TNF-Superfamilie bindet OPG an RANKL und blockiert somit alle stimulierenden Effekte von RANK auf die Osteoklastenentwicklung und neutralisiert so alle biologischen Effekte von RANKL. Diverse Hormone und Zytokine üben durch die Modifikation der Ratio von RANKL zu OPG einen regulatorischen Effekt auf die Knochenresorption aus. Diese ist bei osteolytischen Knochenmetastasen, beim multiplen Myelom und bei der malignen Hyperkalzämie erhöht. Das Gleichgewicht knochenaufbauender wie -abbauender Mechanismen scheint somit durch die Ratio von

  4. 3D simulation of electron and ion transmission of GEM-based detectors

    Science.gov (United States)

    Bhattacharya, Purba; Mohanty, Bedangadas; Mukhopadhyay, Supratik; Majumdar, Nayana; da Luz, Hugo Natal

    2017-10-01

    Time Projection Chamber (TPC) has been chosen as the main tracking system in several high-flux and high repetition rate experiments. These include on-going experiments such as ALICE and future experiments such as PANDA at FAIR and ILC. Different R&D activities were carried out on the adoption of Gas Electron Multiplier (GEM) as the gas amplification stage of the ALICE-TPC upgrade version. The requirement of low ion feedback has been established through these activities. Low ion feedback minimizes distortions due to space charge and maintains the necessary values of detector gain and energy resolution. In the present work, Garfield simulation framework has been used to study the related physical processes occurring within single, triple and quadruple GEM detectors. Ion backflow and electron transmission of quadruple GEMs, made up of foils with different hole pitch under different electromagnetic field configurations (the projected solutions for the ALICE TPC) have been studied. Finally a new triple GEM detector configuration with low ion backflow fraction and good electron transmission properties has been proposed as a simpler GEM-based alternative suitable for TPCs for future collider experiments.

  5. The HadGEM2 family of Met Office Unified Model climate configurations

    Directory of Open Access Journals (Sweden)

    The HadGEM2 Development Team: G. M. Martin

    2011-09-01

    Full Text Available We describe the HadGEM2 family of climate configurations of the Met Office Unified Model, MetUM. The concept of a model "family" comprises a range of specific model configurations incorporating different levels of complexity but with a common physical framework. The HadGEM2 family of configurations includes atmosphere and ocean components, with and without a vertical extension to include a well-resolved stratosphere, and an Earth-System (ES component which includes dynamic vegetation, ocean biology and atmospheric chemistry. The HadGEM2 physical model includes improvements designed to address specific systematic errors encountered in the previous climate configuration, HadGEM1, namely Northern Hemisphere continental temperature biases and tropical sea surface temperature biases and poor variability. Targeting these biases was crucial in order that the ES configuration could represent important biogeochemical climate feedbacks. Detailed descriptions and evaluations of particular HadGEM2 family members are included in a number of other publications, and the discussion here is limited to a summary of the overall performance using a set of model metrics which compare the way in which the various configurations simulate present-day climate and its variability.

  6. KRITIK SOSIAL DALAM KOMIK STRIP PAK BEI

    Directory of Open Access Journals (Sweden)

    Yudhi Novriansyah

    2016-08-01

    Full Text Available This research aimed to do interpret the marking which flange social criticism and know laboring ideology in story of Comic Strip Pak Bei. Research based on theory of structural semiotic according to Ferdinand De Saussure. Using analysis of Syntagmatic as first level of meaning to the text network and also picture, and analysis of Paradigmatic as second level of meaning or implicit meaning (connota-tion, myth, ideology Analysis done to six Comic choice edition of Strip Pak Bei period of November 2004 - Februari 2005 which tend to flange social criticism. At band of syntagmatic, result of research indicate that story theme lifted from social problems that happened in major society. The fact clear progressively when connected by Intertextual with information and texts which have preexisted. At band of Paradigmatic, social criticism tend to emerge dimly, is not transparent. Because of Comic Strip Pak Bei expand in the middle of Java cultural domination that developing myth of criticize as action menacing compatibility and orderliness of society. Story of Comic Strip Pak Bei also confirm dominant ideology in Java society culture, namely ideology of Patriarkhi and Feudalism which still go into effect until now. This prove ideology idea according to Louis Althusser which not again opposition between class, but have been owned and practiced by all social class.

  7. Development, characterization and qualification of first GEM foils produced in India

    Science.gov (United States)

    Shah, Aashaq; Ahmed, Asar; Gola, Mohit; Sharma, Ram Krishna; Malhotra, Shivali; Kumar, Ashok; Naimuddin, Md.; Menon, Pradeep; Srinivasan, K.

    2018-06-01

    The increasing demand for Gas Electron Multiplier (GEM) foils has been driven by their application in many current and proposed high-energy physics experiments. Micropack, a Bengaluru-based company, has established and commercialized GEM foils for the first time in India. Micropack used the double-mask etching technique to successfully produce 10 cm × 10 cm GEM foil. In this paper, we report on the development as well as the geometrical and electrical properties of these foils, including the size uniformity of the holes and leakage current measurements. Our characterization studies show that the foils are of good quality and satisfy all the necessary quality control criteria.

  8. The development of neutron detectors for the GEM instrument at ISIS

    International Nuclear Information System (INIS)

    Rhodes, N.J.; Johnson, M.W.; Schooneveld, E.M.

    2001-01-01

    GEM is a new General Materials diffractometer now being commissioned at ISIS. To meet its broad based scientific programme GEM requires a large area position sensitive detector which covers a wide range of scattering angles and exhibits a high neutron count rate stability. This paper discusses the design of a ZnS/ 6 Li fibre coupled detector array that meets the GEM requirements. Typical detector characteristics are documented together with the current status of the project. Two thirds of the detector array are operational and from the results obtained to date it is already obvious that the impact of this instrument on neutron scattering studies will be profound. (author)

  9. Microstructured boron foil scintillating G-GEM detector for neutron imaging

    Energy Technology Data Exchange (ETDEWEB)

    Fujiwara, Takeshi, E-mail: fujiwara-t@aist.go.jp [Research Institute for Measurement and Analytical Instrumentation, Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki (Japan); Center for Advanced Photonics, Neutron Beam Technology Team, RIKEN, Saitama (Japan); Bautista, Unico [Department of Nuclear Engineering and Management, The University of Tokyo, Tokyo (Japan); Philippine Nuclear Research Institute-Department of Science and Technology (PNRI-DOST), Commonwealth Avenue, Diliman, Quezon City (Philippines); Mitsuya, Yuki [Nuclear Professional School, The University of Tokyo, Tokai-mura, Naka-gun, Ibaraki (Japan); Takahashi, Hiroyuki [Department of Nuclear Engineering and Management, The University of Tokyo, Tokyo (Japan); Yamada, Norifumi L. [Neutron Science Laboratory, Institute of Material Structure Science, High Energy Accelerator Research Organization (KEK) (Japan); Otake, Yoshie; Taketani, Atsushi [Center for Advanced Photonics, Neutron Beam Technology Team, RIKEN, Saitama (Japan); Uesaka, Mitsuru [Nuclear Professional School, The University of Tokyo, Tokai-mura, Naka-gun, Ibaraki (Japan); Toyokawa, Hiroyuki [Research Institute for Measurement and Analytical Instrumentation, Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki (Japan)

    2016-12-01

    In this study, a new simple neutron imaging gaseous detector was successfully developed by combining a micro-structured {sup 10}B foil, a glass gas electron multiplier (G-GEM), and a mirror–lens–charge-coupled device (CCD)–camera system. The neutron imaging system consists of a chamber filled with Ar/CF{sub 4} scintillating gas mixture. Inside this system, the G-GEM is mounted for gas multiplication. The neutron detection in this system is based on the reaction between {sup 10}B and neutrons. A micro-structured {sup 10}B is developed to overcome the issue of low detection efficiency. Secondary electrons excite Ar/CF{sub 4} gas molecules, and high-yield visible photons are emitted from those excited gas molecules during the gas electron multiplication process in the G-GEM holes. These photons are easily detected by a mirror–lens–CCD–camera system. A neutron radiograph is then simply formed. We obtain the neutron images of different materials with a compact accelerator-driven neutron source. We confirm that the new scintillating G-GEM-based neutron imager works properly with low gamma ray sensitivity and exhibits a good performance as a new simple digital neutron imaging device.

  10. A free-volume modification of GEM-QC to correlate VLE and LLE in polymer solutions

    International Nuclear Information System (INIS)

    Radfarnia, H.R.; Taghikhani, V.; Ghotbi, C.; Khoshkbarchi, M.K.

    2004-01-01

    The generalized quasi-chemical (GEM-QC) model proposed by Wang and Vera is modified to correlate better the phase equilibrium and to overcome the shortcoming of the original model to predict the lower critical solution temperature (LCST) of binary polymer solutions. This shortcoming is mainly because the GEM-QC model does not consider the effect of free-volume, which is important in systems containing molecules with large size differences. The proposed modification is based on replacing the combinatorial term of the GEM-QC model by a term proposed by Kontogerogis et al., which includes the effect of the free-volume. The main advantage of the free volume generalized quasi-chemical (GEM-QC-FV) model over the original GEM-QC is its ability to predict the phase behaviour of binary polymer solutions with LCST behaviour. In addition, the free volume UNIQUAC (UNIQUAC-FV) model is used to correlate VLE and LLE experimental data for binary polymer solutions. The comparison of the results obtained from the GEM-QC-FV model and the UNIQUAC-FV model shows the superiority of the GEM-QC-FV model in correlating the VLE and LLE experimental data for binary polymer solutions

  11. Graphics gems II

    CERN Document Server

    Arvo, James

    1991-01-01

    Graphics Gems II is a collection of articles shared by a diverse group of people that reflect ideas and approaches in graphics programming which can benefit other computer graphics programmers.This volume presents techniques for doing well-known graphics operations faster or easier. The book contains chapters devoted to topics on two-dimensional and three-dimensional geometry and algorithms, image processing, frame buffer techniques, and ray tracing techniques. The radiosity approach, matrix techniques, and numerical and programming techniques are likewise discussed.Graphics artists and comput

  12. GEMs with Double Layred Micropattern Electrodes and their Applications

    CERN Document Server

    Di Mauro, A.; Nappi, E.; Oliveira, R.; Peskov, V.; Pietropaolo, F.; Picchi, P.

    We have developed and tested several new designs of GEM detectors with micropattern electrodes manufactured by microelectronic technology. In one design, the inner layer of the detector electrode consists of thin metallic strips and the outer layer is made of a resistive grid manufactured by a screen printing technology. In other designs, the electrodes were made of metallic strips fed by HV via micro-resistors manufactured by a screen printing technology. Due to these features, the new detectors have several important advantages over conventional GEMs or ordinary thick GEMs. For example, the resistive grid (in the first design) and the screen printed resistors (in other designs) limited the current in case of discharges, making these detectors intrinsically spark-protected. We will here describe our tests with the photosensitive versions of these detectors (coated with CsI layers) and the efforts of implementing them in several applications. In particular, we will focus on our activity towards the ALICE RICH...

  13. Modelling Chemical Equilibrium Partitioning with the GEMS-PSI Code

    Energy Technology Data Exchange (ETDEWEB)

    Kulik, D.; Berner, U.; Curti, E

    2004-03-01

    Sorption, co-precipitation and re-crystallisation are important retention processes for dissolved contaminants (radionuclides) migrating through the sub-surface. The retention of elements is usually measured by empirical partition coefficients (Kd), which vary in response to many factors: temperature, solid/liquid ratio, total contaminant loading, water composition, host-mineral composition, etc. The Kd values can be predicted for in-situ conditions from thermodynamic modelling of solid solution, aqueous solution or sorption equilibria, provided that stoichiometry, thermodynamic stability and mixing properties of the pure components are known (Example 1). Unknown thermodynamic properties can be retrieved from experimental Kd values using inverse modelling techniques (Example 2). An efficient, advanced tool for performing both tasks is the Gibbs Energy Minimization (GEM) approach, implemented in the user-friendly GEM-Selector (GEMS) program package, which includes the Nagra-PSI chemical thermodynamic database. The package is being further developed at PSI and used extensively in studies relating to nuclear waste disposal. (author)

  14. Modelling Chemical Equilibrium Partitioning with the GEMS-PSI Code

    International Nuclear Information System (INIS)

    Kulik, D.; Berner, U.; Curti, E.

    2004-01-01

    Sorption, co-precipitation and re-crystallisation are important retention processes for dissolved contaminants (radionuclides) migrating through the sub-surface. The retention of elements is usually measured by empirical partition coefficients (Kd), which vary in response to many factors: temperature, solid/liquid ratio, total contaminant loading, water composition, host-mineral composition, etc. The Kd values can be predicted for in-situ conditions from thermodynamic modelling of solid solution, aqueous solution or sorption equilibria, provided that stoichiometry, thermodynamic stability and mixing properties of the pure components are known (Example 1). Unknown thermodynamic properties can be retrieved from experimental Kd values using inverse modelling techniques (Example 2). An efficient, advanced tool for performing both tasks is the Gibbs Energy Minimization (GEM) approach, implemented in the user-friendly GEM-Selector (GEMS) program package, which includes the Nagra-PSI chemical thermodynamic database. The package is being further developed at PSI and used extensively in studies relating to nuclear waste disposal. (author)

  15. Is Kyoto Fatally Flawed? An Analysis with MacGEM

    International Nuclear Information System (INIS)

    Eyckmans, J.; Van Regemorter, D.; Van Steenberghe, V.

    2002-06-01

    In this paper we present some numerical simulations with the MacGEM model to evaluate the consequences of the recent Marrakesh agreements and the defection of the USA for the Kyoto Protocol. MacGEM is a global marginal abatement cost model for carbon emissions from fossil fuel use based on the GEM-E3-World general equilibrium. Nonparticipation of the USA causes the equilibrium carbon price in Annex B countries to fall by approximately 50% since an important share of permit demand falls out. Carbon sinks enhancement activities enable Parties to fulfil their reduction commitment at lower compliance costs and cause the equilibrium permit price to decrease by 40%. Finally, it is shown that the former Soviet Union and central European countries have substantial monopoly power in the Kyoto carbon permit market. We conclude that the recent accords have eroded completely the Kyoto Protocol's emission targets but that they have the merit to have saved the international climate change negotiation framework

  16. Activity of CERN and LNF groups on large area GEM detectors

    Energy Technology Data Exchange (ETDEWEB)

    Alfonsi, M. [CERN, Geneva (Switzerland); Bencivenni, G. [Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); Brock, I. [Physikalisches Institute der Universitat Bonn, Bonn (Germany); Cerioni, S. [Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); Croci, G.; David, E. [CERN, Geneva (Switzerland); De Lucia, E. [Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); De Oliveira, R. [CERN, Geneva (Switzerland); De Robertis, G. [Sezione INFN di Bari, Bari (Italy); Domenici, D., E-mail: Danilo.Domenici@lnf.infn.i [Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); Duarte Pinto, S. [CERN, Geneva (Switzerland); Felici, G.; Gatta, M.; Jacewicz, M. [Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); Loddo, F. [Sezione INFN di Bari, Bari (Italy); Morello, G. [Dipeartimento di Fisica Universita della Calabria e INFN, Cosenza (Italy); Pistilli, M. [Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); Ranieri, A. [Sezione INFN di Bari, Bari (Italy); Ropelewski, L. [CERN, Geneva (Switzerland); Sauli, F. [TERA Foundation, Novara (Italy)

    2010-05-21

    We report on the activity of CERN and INFN-LNF groups on the development of large area GEM detectors. The two groups work together within the RD51 Collaboration, to aim at the development of Micro-pattern Gas detectors technologies. The vast request for large area foils by the GEM community has driven a change in the manufacturing procedure by the TS-DEM-PMT laboratory, needed to overcome the previous size limitation of 450x450mm{sup 2}. Now a single-mask technology is used allowing foils to be made as large as 450x2000mm{sup 2}. The limitation in the short size, due to the definite width of the raw material, can be overcome by splicing more foils together. A 10x10cm{sup 2} GEM detector with the new single-mask foil has been tested with X-rays and the results are shown. Possible future applications for large area GEM are the TOTEM experiment upgrade at CERN, and the KLOE-2 experiment at the Dafne {Phi}-factory in Frascati.

  17. Activity of CERN and LNF groups on large area GEM detectors

    International Nuclear Information System (INIS)

    Alfonsi, M.; Bencivenni, G.; Brock, I.; Cerioni, S.; Croci, G.; David, E.; De Lucia, E.; De Oliveira, R.; De Robertis, G.; Domenici, D.; Duarte Pinto, S.; Felici, G.; Gatta, M.; Jacewicz, M.; Loddo, F.; Morello, G.; Pistilli, M.; Ranieri, A.; Ropelewski, L.; Sauli, F.

    2010-01-01

    We report on the activity of CERN and INFN-LNF groups on the development of large area GEM detectors. The two groups work together within the RD51 Collaboration, to aim at the development of Micro-pattern Gas detectors technologies. The vast request for large area foils by the GEM community has driven a change in the manufacturing procedure by the TS-DEM-PMT laboratory, needed to overcome the previous size limitation of 450x450mm 2 . Now a single-mask technology is used allowing foils to be made as large as 450x2000mm 2 . The limitation in the short size, due to the definite width of the raw material, can be overcome by splicing more foils together. A 10x10cm 2 GEM detector with the new single-mask foil has been tested with X-rays and the results are shown. Possible future applications for large area GEM are the TOTEM experiment upgrade at CERN, and the KLOE-2 experiment at the Dafne Φ-factory in Frascati.

  18. arXiv GEM Foil Quality Assurance For The ALICE TPC Upgrade

    CERN Document Server

    INSPIRE-00019412; Hildén, Timo

    2018-01-01

    The ALICE (A Large Ion Collider Experiment) experiment at the Large Hadron Collider (LHC) at CERN is dedicated to heavy ion physics to explore the structure of strongly interacting matter. The Time Projection Chamber (TPC) of ALICE is a tracking detector located in the central region of the experiment. It offers excellent tracking capabilities as well as particle identification. After the second long shutdown (LS2) the LHC will run at substantially higher luminosities. To be able to increase the data acquisition rate by a factor of 100, the ALICE TPC experiment has to replace the Multi-Wire Proportional Chamber (MWPC) –based readout chambers. The MWPC are operated with gating grid that limits the rate to O(kHz). The new ReadOut Chamber (ROC) design is based on Gas Electron Multiplier (GEM) technology operating in continuous mode. The current GEM productions scheme foresees the production of more than 800 GEM foils of different types. To fulfill the requirements on the performance of the GEM TPC readout, nec...

  19. Gaseous elemental mercury (GEM) fluxes over canopy of two typical subtropical forests in south China

    Science.gov (United States)

    Yu, Qian; Luo, Yao; Wang, Shuxiao; Wang, Zhiqi; Hao, Jiming; Duan, Lei

    2018-01-01

    Mercury (Hg) exchange between forests and the atmosphere plays an important role in global Hg cycling. The present estimate of global emission of Hg from natural source has large uncertainty, partly due to the lack of chronical and valid field data, particularly for terrestrial surfaces in China, the most important contributor to global atmospheric Hg. In this study, the micrometeorological method (MM) was used to continuously observe gaseous elemental mercury (GEM) fluxes over forest canopy at a mildly polluted site (Qianyanzhou, QYZ) and a moderately polluted site (Huitong, HT, near a large Hg mine) in subtropical south China for a full year from January to December in 2014. The GEM flux measurements over forest canopy in QYZ and HT showed net emission with annual average values of 6.67 and 0.30 ng m-2 h-1, respectively. Daily variations of GEM fluxes showed an increasing emission with the increasing air temperature and solar radiation in the daytime to a peak at 13:00, and decreasing emission thereafter, even as a GEM sink or balance at night. High temperature and low air Hg concentration resulted in the high Hg emission in summer. Low temperature in winter and Hg absorption by plant in spring resulted in low Hg emission, or even adsorption in the two seasons. GEM fluxes were positively correlated with air temperature, soil temperature, wind speed, and solar radiation, while it is negatively correlated with air humidity and atmospheric GEM concentration. The lower emission fluxes of GEM at the moderately polluted site (HT) when compared with that in the mildly polluted site (QYZ) may result from a much higher adsorption fluxes at night in spite of a similar or higher emission fluxes during daytime. This shows that the higher atmospheric GEM concentration at HT restricted the forest GEM emission. Great attention should be paid to forests as a crucial increasing Hg emission source with the decreasing atmospheric GEM concentration in polluted areas because of Hg

  20. Krafttraining bei älteren "frail" Personen

    Directory of Open Access Journals (Sweden)

    Kapan A

    2013-01-01

    Full Text Available Aufgrund der demographischen Entwicklung in den westlichen Industrieländern kann bei einem Ausbleiben adäquater Präventionsmaßnahmen davon ausgegangen werden, dass in Österreich im Jahr 2050 356.000 gebrechliche („frail“ und 1,5 Millionen Personen mit Vorstufen erwartet werden können. Im Alter von 50–70 Jahren kann auch bei gesunder Ernährung und körperlicher Aktivität die Muskelkraft um bis zu 30 % nachlassen. Für den Erhalt der Mobilität und um dem Muskelabbau entgegenzuwirken nimmt das körperliche Training, vor allem das Krafttraining, einen wichtigen Stellenwert ein.

  1. Development of a time projection chamber using gas electron multipliers (GEM-TPC)

    International Nuclear Information System (INIS)

    Oda, S.X.; Hamagaki, H.; Ozawa, K.; Inuzuka, M.; Sakaguchi, T.; Isobe, T.; Gunji, T.; Morino, Y.; Saito, S.; Yamaguchi, Y.L.; Sawada, S.; Yokkaichi, S.

    2006-01-01

    We developed a prototype time projection chamber using gas electron multipliers (GEM-TPC) for high energy heavy ion collision experiments. To investigate its performance, we conducted a beam test with three kinds of gases (Ar(90%)-CH 4 (10%), Ar(70%)-C 2 H 6 (30%) and CF 4 ). Detection efficiency of 99%, and spatial resolution of 79μm in the pad-row direction and 313μm in the drift direction were achieved. The test results show that the GEM-TPC meets the requirements for high energy heavy ion collision experiments. The configuration and performance of the GEM-TPC are described

  2. Gallium Electromagnetic (GEM) Thrustor Concept and Design

    Science.gov (United States)

    Polzin, Kurt A.; Markusic, Thomas E.

    2006-01-01

    We describe the design of a new type of two-stage pulsed electromagnetic accelerator, the gallium electromagnetic (GEM) thruster. A schematic illustration of the GEM thruster concept is given in Fig. 1. In this concept, liquid gallium propellant is pumped into the first stage through a porous metal electrode using an electromagneticpump[l]. At a designated time, a pulsed discharge (approx.10-50 J) is initiated in the first stage, ablating the liquid gallium from the porous electrode surface and ejecting a dense thermal gallium plasma into the second state. The presence of the gallium plasma in the second stage serves to trigger the high-energy (approx.500 I), send-stage puke which provides the primary electromagnetic (j x B) acceleration.

  3. Osteoporose bei Mb. Bechterew - neue Ansätze

    Directory of Open Access Journals (Sweden)

    Obermayer-Pietsch B

    1999-01-01

    Full Text Available Eine axiale Osteoporose und daraus resultierende vertebrale Kompressionsfrakturen sind häufige Symptome eines Mb. Bechterew (MbB, Spondylarthritis ankylosans. Als ein möglicher genetischer Faktor der Osteoporose wurde eine Assoziation der Knochendichte (BMD mit BsmI- und FokI-Polymorphismen im Vitamin D-Rezeptor-(VDR-Gen publiziert. In der vorliegenden Studie wurden die Beziehungen zwischen diesen Polymorphismen, Knochenstoffwechsel, BMD und Aktivitätsindizes bei Patienten mit MbB untersucht. Bei 47 MbB-Patienten wurden Aktivitätsindizes und morphologische Parameter sowie BMD-Messungen (Dual-Röntgen-Absorptiometrie an Wirbelsäule und Schenkelhals im Vergleich zu 52 gesunden, altersgleichen Personen erhoben. Die Laborbestimmungen umfaßten biochemische Aktivitätsparameter, HLA-Typisierung sowie Knochenan- und -abbaumarker. Aus peripheren Leukozyten wurde genomische DNA präpariert und mittels Polymerase-Kettenreaktion (PCR und anschließender FokI- und BsmI-Restriktion der VDR-Genotyp nach vorhandenen bzw. fehlenden Schnittstellen (f/b bzw. F/B bestimmt. Bei MbB-Patienten fand sich eine Osteoporose deutlich häufiger als in der Kontrollgruppe. Eine Zuordnung von Aktivitätsindizes, BMD und Knochenstoffwechselparametern zu den Genotypen zeigte bei männlichen MbB-Patienten sowohl eine Assoziation der WS-Knochendichte als auch der Entzündungsmarker mit FokI-, nicht jedoch mit BsmI-Genotypen des VDR. Die pathophysiologischen Mechanismen dieser Assoziation, insbesondere mit der entzündlichen Aktivität des Mb. Bechterew, sind noch ungeklärt. Eine frühzeitige Erfassung des Osteoporoserisikos bei MbB-Patienten mittels molekularbiologischer Tests könnte eine rechtzeitige Prophylaxe und Therapie dieser Komplikation ermöglichen.

  4. Application of CMOS charge-sensitive preamplifier in triple-GEM detector

    International Nuclear Information System (INIS)

    Lai Yongfang; Li Jin; Chinese Academy of Sciences, Beijing; Deng Zhi; Li Yulan; Liu Yinong; Li Yuanjing

    2006-01-01

    Among the various micro-pattern gas detectors (MPGD) that are available, the gas electron multiplier (GEM) detector is an attractive gas detector that has been used in particle physics experiments. However the GEM detector usually needs thousands of preamplifier units for its large number of micro-pattern readout strips or pads, which leads to considerable difficulties and complexities for front end electronics (FEE). Nowadays, by making use of complementary metal-oxide semiconductor (CMOS)-based application specific integrated circuit (ASIC), it is feasible to integrate hundreds of preamplifier units and other signal process circuits in a small-sized chip, which can be bound to the readout strips or pads of a micro-pattern particle detector (MPPD). Therefore, CMOS ASIC may provide an ideal solution to the readout problem of MPPD. In this article, a triple GEM detector is constructed and one of its readout strips is connected to a CMOS charge-sensitive preamplifier chip. The chip was exposed to an 55 Fe source of 5.9 kev X-ray, and the amplitude spectrum of the chip was tested, and it was found that the energy resolution was approximately 27%, which indicates that the chip can be used in triple GEM detectors. (authors)

  5. Analysis of current situation of information disclosure of listed companies on GEM

    Directory of Open Access Journals (Sweden)

    Zhirong Shen

    2017-03-01

    Full Text Available In the afternoon on October 23th, 2009, GEM was officially launched in our country. Due to the lack of experience in the market supervision, information disclosure violations frequently occurred. In April 2015, Shenzhen Stock Exchange puts forward morning information disclosure system to strengthen the reform of information disclosure system. Therefore, this paper deeply focuses on the current situation of information disclosure violations on GEM for the purpose of attracting more attention to the problems. Through studying the information disclosure violations of the listed companies on GEM from 2011 to September 30th, 2015, this paper divides the violations into the following four types: false record, misleading statement, material misstatement and delayed disclosure. On the other hand, we find that these types of violations are concurrent. From this discussion, we may safely draw the conclusion that the information disclosure of listed companies on GEM has the problem of untruthfulness, incorrectness, incompleteness and delay.

  6. Characteristics of triple GEM detector for the ALICE TPC upgrade at CERN

    International Nuclear Information System (INIS)

    Patra, Rajendra Nath; Singaraju, R.N.; Ahammed, Z.; Nayak, T.K.; Viyogi, Y.P.; Biswas, S.

    2016-01-01

    Gas Electron Multiplier (GEM) detector, introduced by F. Sauliin 1997 and has been widely improved in last two decades for applications to high energy physics experiments and imaging. GEM detectors have several advantages, like good spatial resolution (∼100 μm), high detection efficiency (>98%), high rate handling capability (∼105 Hz/mm"2 ) and reasonable time response (∼5 ns). The unique features of the GEM detector make it suitable for experiments at Large Hadron Collider (LHC) at CERN and FAIR at GSI. With the increase of beam luminosity of LHC for its next phase of running from the year 2020, the ALICE experiment is planning to take data for PbPb collisions at a rate of 50 kHz. The ALICE Time Projection Chamber (TPC) will be upgraded by GEM based read-out to fulfil this future goal. In this report, results of a thorough test in the laboratory using a newly developed online data monitoring system are discussed

  7. Uniformity studies in large area triple-GEM based detectors

    Energy Technology Data Exchange (ETDEWEB)

    Akl, M. Abi [Science Program, Texas A& M University at Qatar, PO Box 23874, Doha (Qatar); Bouhali, O., E-mail: othmane.bouhali@qatar.tamu.edu [Science Program, Texas A& M University at Qatar, PO Box 23874, Doha (Qatar); Qatar Computing Research Institute, Hamad Bin Khalifa University, PO Box 5825, Doha (Qatar); Castaneda, A.; Maghrbi, Y.; Mohamed, T. [Science Program, Texas A& M University at Qatar, PO Box 23874, Doha (Qatar)

    2016-10-01

    Gas Electron Multiplier (GEM) based detectors have been used in many applications since their introduction in 1997. Large areas, e.g. exceeding 30×30 cm{sup 2}, of GEM detectors are foreseen in future experiments which puts stringent requirements on the uniformity of response across the detection area. We investigate the effect of small variations of several parameters that could affect the uniformity. Parameters such as the anode pitch, the gas gap, the size and the shape of the holes are investigated. Simulation results are presented and compared to previous experimental data.

  8. HydroGEM, a hydrogen fuelled utility vehicle. Case study

    International Nuclear Information System (INIS)

    Hoevenaars, A.J.; Kraaij, G.J.; De Bruijne, M.; Weeda, M.

    2010-02-01

    This report describes the conversion of a Global Electric Motorcars (GEM, a Chrysler company) electric utility vehicle into a Fuel Cell Vehicle called HydroGEM, at the Energy research Centre of the Netherlands (ECN). The report is prepared as a case study within the framework of Task 18 on 'Evaluation of Integrated Hydrogen Systems' of the IEA Hydrogen Implementing Agreement. The vehicle's fuel cell system was designed in 2005, manufactured and built into the vehicle in 2006 and operated from 2007 onwards. The design-choices, assembly, operation and maintenance-issues are presented and discussed.

  9. 16 CFR 23.25 - Misuse of the word “gem.”

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Misuse of the word âgem.â 23.25 Section 23... JEWELRY, PRECIOUS METALS, AND PEWTER INDUSTRIES § 23.25 Misuse of the word “gem.” (a) It is unfair or deceptive to use the word “gem” to describe, identify, or refer to a ruby, sapphire, emerald, topaz, or...

  10. Reduction experiment of FeO-bearing amorphous silicate: application to origin of metallic iron in GEMS

    Energy Technology Data Exchange (ETDEWEB)

    Matsuno, Junya; Tsuchiyama, Akira; Miyake, Akira [Department of Geology and Mineralogy, Graduate School of Science, Kyoto University, Kitashirakawa-Oiwake, Sakyo-ku, Kyoto 606-8502 (Japan); Noguchi, Ryo [Department of Earth and Space Science, Graduate School of Science, Osaka University, 1-1 Machikaneyama, Toyonaka, Osaka 560-0043 (Japan); Ichikawa, Satoshi, E-mail: jmatsuno@kueps.kyoto-u.ac.jp [Institute for Nano-science Design, Osaka University, 1-3 Machikaneyama, Toyonaka, Osaka 560-8531 (Japan)

    2014-09-10

    Glass with embedded metal and sulfides (GEMS) are amorphous silicates included in anhydrous interplanetary dust particles (IDPs) and can provide information about material evolution in our early solar system. Several formation processes for GEMS have been proposed so far, but these theories are still being debated. To investigate a possible GEMS origin by reduction of interstellar silicates, we synthesized amorphous silicates with a mean GEMS composition and performed heating experiments in a reducing atmosphere. FeO-bearing amorphous silicates were heated at 923 K and 973 K for 3 hr, and at 1023 K for 1-48 hr at ambient pressure in a reducing atmosphere. Fe grains formed at the interface between the silicate and the reducing gas through a reduction. In contrast, TEM observations of natural GEMS show that metallic grains are uniformly embedded in amorphous silicates. Therefore, the present study suggests that metallic inclusions in GEMS could not form as reduction products and that other formation process such as condensation or irradiation are more likely.

  11. Overview of the GEM muon system cosmic ray test program at the SSCL

    International Nuclear Information System (INIS)

    Milner, E.C.

    1993-04-01

    Muon track resolution exceeding 75-μm per plane is one of the main strengths of the GEM detector design, and will be crucial in searches for Higgs Bosons, heavy Z-Bosons, technicolor, and supersymmetry. Achieving this resolution coal requires improved precision in muon chambers and their alignment. A cosmic ray test stand known as the Texas Test Rio, (TTR) has been created at the SSCL for studying candidate GEM muon chamber technologies. Test results led to selecting Cathode Strip Chambers (CSC) as the GEM muon system baseline chamber technology

  12. The GEM code. A simulation program for the evaporation and the fission process of an excited nucleus

    Energy Technology Data Exchange (ETDEWEB)

    Furihata, Shiori [Mitsubishi Research Institute Inc., Tokyo (Japan); Niita, Koji [Research Organization for Information Science and Technology, Tokai, Ibaraki (Japan); Meigo, Shin-ichiro; Ikeda, Yujiro; Maekawa, Fujio [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2001-03-01

    The GEM code is a simulation program which describes the de-excitation process of an excited nucleus, which is based on the Generalized Evaporation Model and the Atchison fission model. It has been shown that the combination of the Bertini intranuclear cascade model and GEM accurately predicts the cross sections of light fragments, such as Be produced from the proton-induced reactions. It has also been shown that the use of the reevaluated parameters in the Atchison model improves predictions of cross sections of fission fragments produced from the proton-induced reaction on Au. In this report, we present details and the usage of the GEM code. Furthermore, the results of benchmark calculations are shown by using the combination of the Bertini intranuclear cascade model and the GEM code (INC/GEM). Neutron spectra and isotope production cross sections from the reactions on various targets irradiated by protons are calculated with INC/GEM. Those results are compared with experimental data as well as the calculation results with LAHET. INC/GEM reproduces the experiments of double differential neutron emissions from the reaction on Al and Pb. The isotopic distributions for He, Li, and Be produced from the reaction on Ag are in good agreement with experimental data within 50%, although INC/GEM underestimates those of heavier nuclei than O. It is also shown that the predictions with INC/GEM for isotope production of light fragments, such as Li and Be, are better than those calculation with LAHET, particularly for heavy target. INC/GEM also gives better estimates of the cross sections of fission products than LAHET. (author)

  13. UMA PROSPOSTA DEDUTIVISTA PARA PRINCÍPIOS CONTÁBEIS

    Directory of Open Access Journals (Sweden)

    Paulo Schmidt

    2009-09-01

    Full Text Available A proposta deste estudo a apresentar um breve relato sobre a evolução do pensamento cientifico ocorrida na física com a substituição dos princípios contábeis e filosófico, desde a Antiguidade grega ate os dias de hoje, como forma de fundamentar o posicionamento contrario ao raciocínio indutivo para o estabelecimento de uma estrutura conceitual para a contabilidade e para o desenvolvimento dos princípios contábeis. Apos essa incursão pelo campo filosófico, será aduzido um dos trabalhos de D. R. Scott, ex-professor da Universidade de Michigan, que já na década de 1930 defendia o processo de raciocínio dedutivo e a necessidade de coerência e unidade para o estabelecimento dos princípios contábeis. Este estudo justifica-se, principalmente, porque ainda existem pesquisadores da área contábil que defendem o método indutivo com único procedimento cientifico capaz de levar a certeza, Como defendia Descartes. Alem disso, mesmo apos a revolução cientifica princípios teóricos de Newton, pelos princípios da teoria da relatividade de Einstein, alguns pesquisadores defendem a imutabilidade dos princípios contábeis, como sendo verdades indubitáveis, não aceitando o permanente desenvolvimento da teoria contábil e sua continua adaptabilidade a nova realidade ambiental. A contabilidade, assim como toda disciplina do conhecimento humano que postula um patamar cientifico, deve estruturar-se com base em um conjunto de princípios racionalmente dispostos. Diante desse panorama, faz-se mister inquirir se os princípios contábeis podem ser oniscientes e impassíveis as mudanças do mundo?

  14. Pneumonia in immunosuppressed patients; Pneumonien bei immunsupprimierten Patienten

    Energy Technology Data Exchange (ETDEWEB)

    Solyanik, O.; Gaass, T.; Hellbach, K. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Campus Grosshadern, Institut fuer klinische Radiologie, Muenchen (Germany); Dinkel, J. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Campus Grosshadern, Institut fuer klinische Radiologie, Muenchen (Germany); Comprehensive Pneumology Center Munich (CPC-M), Muenchen (Germany)

    2017-01-15

    Pulmonary infections are a common complication in immunosuppressed patients with a frequently fatal prognosis despite modern prophylactic therapy. An early and correct diagnosis is important for initiation of the appropriate therapy. Chest radiography is the preferred initial imaging examination but is not accurate enough for the detection of pulmonary infections in immunosuppressed patients. Pneumonia is caused by a broad spectrum of pathogens in immunocompromised patients. In addition to imaging, the clinical history and epidemiology also play an important role in the diagnostics. Using epidemiological and anamnestic information, computed tomography (CT) shows a significantly better sensitivity and specificity particularly for the diagnosis of atypical forms of pneumonia. Due to the exact imaging of the different infiltration patterns CT provides an increased sensitivity with respect to the etiological classification of pulmonary infections. This article reviews in particular the radiological findings of commonly occurring pulmonary infections in immunosuppressed patients. (orig.) [German] Pneumonien bei immunsupprimierten Patienten sind haeufige Komplikationen, die trotzt moderner Prophylaxe toedlich verlaufen koennen. Eine korrekte Diagnose ist daher von entscheidender Bedeutung, um die richtige Therapie einleiten zu koennen. Die Roentgenthoraxaufnahme ist selten spezifisch genug fuer die genaue Einordnung atypischer Pneumonien in Folge einer Immunsuppression. Pneumonien unter Immunsuppression werden durch ein sehr breites Erregerspektrum verursacht. Eine wichtige Rolle bei der Diagnosefindung spielen neben der Bildgebung auch die klinische Anamnese und Epidemiologie. Mithilfe der klinischen Anamnese und Epidemiologie bietet die Computertomographie (CT) bei immunsupprimierten Patienten zum einen eine erhoehte Sensitivitaet bei der Detektion insbesondere atypischer Pneumonien. Zum anderen weist die CT durch die exakte Abbildung unterschiedlicher Infiltratmuster

  15. Performance study of a GEM-TPC prototype using cosmic rays

    International Nuclear Information System (INIS)

    Li Yulan; Qi Huirong; Li Jin; Gao Yuanning; Li Yuanjing; Yang Zhenwei; Fujii, Keisuke; Matsuda, Takeshi

    2008-01-01

    Time projection chambers (TPCs) have been successfully used as the central tracking devices in a number of high-energy physics experiments. However, the performance requirements on TPCs for future high-energy physics experiments greatly exceed the abilities of traditional TPCs read out by multi-wire proportional chambers (MWPCs). Micro-pattern gas detectors (MPGDs), such as gas electron multipliers (GEMs) or micromegas, have great potential to improve TPC performance when used as readout detectors. In order to evaluate its feasibility, a GEM-based TPC prototype with a drift length up to 50 cm was designed. Measurements of the spatial resolution of cosmic-ray tracks without and with a magnetic field (B=1 T) are presented. A very good performance is achieved, matching the analytic formula for the spatial resolution of a MPGD-readout TPC. A dedicated study shows that the increase of GEM detector gain can improve the TPC's spatial resolution.

  16. Gaseous elemental mercury (GEM fluxes over canopy of two typical subtropical forests in south China

    Directory of Open Access Journals (Sweden)

    Q. Yu

    2018-01-01

    Full Text Available Mercury (Hg exchange between forests and the atmosphere plays an important role in global Hg cycling. The present estimate of global emission of Hg from natural source has large uncertainty, partly due to the lack of chronical and valid field data, particularly for terrestrial surfaces in China, the most important contributor to global atmospheric Hg. In this study, the micrometeorological method (MM was used to continuously observe gaseous elemental mercury (GEM fluxes over forest canopy at a mildly polluted site (Qianyanzhou, QYZ and a moderately polluted site (Huitong, HT, near a large Hg mine in subtropical south China for a full year from January to December in 2014. The GEM flux measurements over forest canopy in QYZ and HT showed net emission with annual average values of 6.67 and 0.30 ng m−2 h−1, respectively. Daily variations of GEM fluxes showed an increasing emission with the increasing air temperature and solar radiation in the daytime to a peak at 13:00, and decreasing emission thereafter, even as a GEM sink or balance at night. High temperature and low air Hg concentration resulted in the high Hg emission in summer. Low temperature in winter and Hg absorption by plant in spring resulted in low Hg emission, or even adsorption in the two seasons. GEM fluxes were positively correlated with air temperature, soil temperature, wind speed, and solar radiation, while it is negatively correlated with air humidity and atmospheric GEM concentration. The lower emission fluxes of GEM at the moderately polluted site (HT when compared with that in the mildly polluted site (QYZ may result from a much higher adsorption fluxes at night in spite of a similar or higher emission fluxes during daytime. This shows that the higher atmospheric GEM concentration at HT restricted the forest GEM emission. Great attention should be paid to forests as a crucial increasing Hg emission source with the decreasing atmospheric GEM concentration

  17. Discriminating cosmic muons and X-rays based on rise time using a GEM detector

    Science.gov (United States)

    Wu, Hui-Yin; Zhao, Sheng-Ying; Wang, Xiao-Dong; Zhang, Xian-Ming; Qi, Hui-Rong; Zhang, Wei; Wu, Ke-Yan; Hu, Bi-Tao; Zhang, Yi

    2016-08-01

    Gas electron multiplier (GEM) detectors have been used in cosmic muon scattering tomography and neutron imaging over the last decade. In this work, a triple GEM device with an effective readout area of 10 cm × 10 cm is developed, and a method of discriminating between cosmic muons and X-rays based on rise time is tested. The energy resolution of the GEM detector is tested by 55Fe ray source to prove the GEM detector has a good performance. Analysis of the complete signal-cycles allows us to get the rise time and pulse heights. The experiment result indicates that cosmic muons and X-rays can be discriminated with an appropriate rise time threshold. Supported by National Natural Science Foundation of China (11135002, 11275235, 11405077, 11575073)

  18. Data Integration for Spatio-Temporal Patterns of Gene Expression of Zebrafish development: the GEMS database

    Directory of Open Access Journals (Sweden)

    Belmamoune Mounia

    2008-06-01

    Full Text Available The Gene Expression Management System (GEMS is a database system for patterns of gene expression. These patterns result from systematic whole-mount fluorescent in situ hybridization studies on zebrafish embryos. GEMS is an integrative platform that addresses one of the important challenges of developmental biology: how to integrate genetic data that underpin morphological changes during embryogenesis. Our motivation to build this system was by the need to be able to organize and compare multiple patterns of gene expression at tissue level. Integration with other developmental and biomolecular databases will further support our understanding of development. The GEMS operates in concert with a database containing a digital atlas of zebrafish embryo; this digital atlas of zebrafish development has been conceived prior to the expansion of the GEMS. The atlas contains 3D volume models of canonical stages of zebrafish development in which in each volume model element is annotated with an anatomical term. These terms are extracted from a formal anatomical ontology, i.e. the Developmental Anatomy Ontology of Zebrafish (DAOZ. In the GEMS, anatomical terms from this ontology together with terms from the Gene Ontology (GO are also used to annotate patterns of gene expression and in this manner providing mechanisms for integration and retrieval . The annotations are the glue for integration of patterns of gene expression in GEMS as well as in other biomolecular databases. At the one hand, zebrafish anatomy terminology allows gene expression data within GEMS to be integrated with phenotypical data in the 3D atlas of zebrafish development. At the other hand, GO terms extend GEMS expression patterns integration to a wide range of bioinformatics resources.

  19. A refined gravity model from Lageos /GEM-L2/

    Science.gov (United States)

    Lerch, F. J.; Klosko, S. M.; Patel, G. B.

    1982-01-01

    Lageos satellite laser ranging (SLR) data taken over a 2.5 yr period were employed to develop the Goddard Earth Model GEM-L2, a refined gravity field model. Additional data was gathered with 30 other satellites, resulting in spherical harmonics through degree and order 20, based on over 600,000 measurements. The Lageos data was accurate down to 10 cm, after which the GEM 9 data were used to make adjustments past order 7. The resolution of long wavelength activity, through degree and order 4, was made possible by the Lageos data. The GEM-L2 model features a 20 x 20 geopotential, tracking station coordinates (20), 5-day polar motion and A1-UT1 values, and a GM value of 398,600.607 cu km/sq sec. The accuracy of station positioning has been raised to within 6 cm total position globally and within 1.8 cm in baselines. It is concluded that SLR is useful for measuring tectonic plate motions and inter-plate deformations.

  20. The TOTEM GEM Telescope (T2) at the LHC

    International Nuclear Information System (INIS)

    Quinto, M.; Berretti, M.; David, E.; Garcia, F.; Greco, V.; Heino, J.; Hilden, T.; Kurvinen, K.; Lami, S.; Latino, G.; Lauhakangas, R.; Oliveri, E.; Ropelewski, L.; Scribano, A.; Turini, N.; Stenis, M. van

    2011-01-01

    The TOTEM T2 telescope will measure inelastically produced charged particles in the forward region of the LHC Interaction Point 5. Each arm of the telescope consists in a set of 20 triple-GEM (Gas Electron Multiplier) detectors with tracking and trigger capabilities. The GEM technology has been considered for the design of TOTEM very forward T2 telescopes thanks to its characteristics: large active areas, good position and timing resolution, excellent rate capability and radiation hardness. Each of the four T2 half arms has been fully assembled and equipped with electronics at CERN and systematically tested in the SPS beam line H8 in 2008/09. After some optimization, the operation of the GEM chambers was fully satisfactory and the T2 telescopes were installed and commissioned in their final positions at the LHC interaction point. During the first LHC run (December 2009) the T2 telescopes have collected data, at 900 GeV and 2.36 TeV. We will present here the performances of the detector and the preliminary results obtained using the data collected.

  1. The TOTEM GEM Telescope (T2) at the LHC

    Energy Technology Data Exchange (ETDEWEB)

    Quinto, M. [INFN Sezione di Bari, Via E.Orabona n 4, 70126 Bari (Italy); Berretti, M. [University of Siena, Physics Department, Via Roma 56, I-53100 Siena (Italy); INFN Sezione di Pisa, Largo B. Pontecorvo, 3. I-56127. Pisa (Italy); David, E. [CERN, PH Department, 1211 Geneva 23, Geneva (Switzerland); Garcia, F. [University of Helsinki, Institute of Physics and Department of Physical Sciences, Helsinki (Finland); Greco, V. [University of Siena, Physics Department, Via Roma 56, I-53100 Siena (Italy); INFN Sezione di Pisa, Largo B. Pontecorvo, 3. I-56127. Pisa (Italy); Heino, J.; Hilden, T.; Kurvinen, K. [University of Helsinki, Institute of Physics and Department of Physical Sciences, Helsinki (Finland); Lami, S. [INFN Sezione di Pisa, Largo B. Pontecorvo, 3. I-56127. Pisa (Italy); Latino, G. [University of Siena, Physics Department, Via Roma 56, I-53100 Siena (Italy); INFN Sezione di Pisa, Largo B. Pontecorvo, 3. I-56127. Pisa (Italy); Lauhakangas, R. [University of Helsinki, Institute of Physics and Department of Physical Sciences, Helsinki (Finland); Oliveri, E. [University of Siena, Physics Department, Via Roma 56, I-53100 Siena (Italy); INFN Sezione di Pisa, Largo B. Pontecorvo, 3. I-56127. Pisa (Italy); Ropelewski, L. [CERN, PH Department, 1211 Geneva 23, Geneva (Switzerland); Scribano, A.; Turini, N. [University of Siena, Physics Department, Via Roma 56, I-53100 Siena (Italy); INFN Sezione di Pisa, Largo B. Pontecorvo, 3. I-56127. Pisa (Italy); Stenis, M. van [CERN, PH Department, 1211 Geneva 23, Geneva (Switzerland)

    2011-06-15

    The TOTEM T2 telescope will measure inelastically produced charged particles in the forward region of the LHC Interaction Point 5. Each arm of the telescope consists in a set of 20 triple-GEM (Gas Electron Multiplier) detectors with tracking and trigger capabilities. The GEM technology has been considered for the design of TOTEM very forward T2 telescopes thanks to its characteristics: large active areas, good position and timing resolution, excellent rate capability and radiation hardness. Each of the four T2 half arms has been fully assembled and equipped with electronics at CERN and systematically tested in the SPS beam line H8 in 2008/09. After some optimization, the operation of the GEM chambers was fully satisfactory and the T2 telescopes were installed and commissioned in their final positions at the LHC interaction point. During the first LHC run (December 2009) the T2 telescopes have collected data, at 900 GeV and 2.36 TeV. We will present here the performances of the detector and the preliminary results obtained using the data collected.

  2. Gravity model improvement using GEOS 3 /GEM 9 and 10/. [and Seasat altimetry data

    Science.gov (United States)

    Lerch, F. J.; Wagner, C. A.; Klosko, S. M.; Laubscher, R. E.

    1979-01-01

    Although errors in previous gravity models have produced large uncertainties in the orbital position of GEOS 3, significant improvement has been obtained with new geopotential solutions, Goddard Earth Model (GEM) 9 and 10. The GEM 9 and 10 solutions for the potential coefficients and station coordinates are presented along with a discussion of the new techniques employed. Also presented and discussed are solutions for three fundamental geodetic reference parameters, viz. the mean radius of the earth, the gravitational constant, and mean equatorial gravity. Evaluation of the gravity field is examined together with evaluation of GEM 9 and 10 for orbit determination accuracy. The major objectives of GEM 9 and 10 are achieved. GEOS 3 orbital accuracies from these models are about 1 m in their radial components for 5-day arc lengths. Both models yield significantly improved results over GEM solutions when compared to surface gravimetry, Skylab and GEOS 3 altimetry, and highly accurate BE-C (Beacon Explorer-C) laser ranges. The new values of the parameters discussed are given.

  3. PLC-controlled cryostats for the BlackGEM and MeerLICHT detectors

    Science.gov (United States)

    Raskin, Gert; Morren, Johan; Pessemier, Wim; Bloemen, Steven; Klein-Wolt, Marc; Roelfsema, Ronald; Groot, Paul; Aerts, Conny

    2016-08-01

    BlackGEM is an array of telescopes, currently under development at the Radboud University Nijmegen and at NOVA (Netherlands Research School for Astronomy). It targets the detection of the optical counterparts of gravitational waves. The first three BlackGEM telescopes are planned to be installed in 2018 at the La Silla observatory (Chile). A single prototype telescope, named MeerLICHT, will already be commissioned early 2017 in Sutherland (South Africa) to provide an optical complement for the MeerKAT radio array. The BlackGEM array consists of, initially, a set of three robotic 65-cm wide-field telescopes. Each telescope is equipped with a single STA1600 CCD detector with 10.5k x 10.5k 9-micron pixels that covers a 2.7 square degrees field of view. The cryostats for housing these detectors are developed and built at the KU Leuven University (Belgium). The operational model of BlackGEM requires long periods of reliable hands-off operation. Therefore, we designed the cryostats for long vacuum hold time and we make use of a closed-cycle cooling system, based on Polycold PCC Joule-Thomson coolers. A single programmable logic controller (PLC) controls the cryogenic systems of several BlackGEM telescopes simultaneously, resulting in a highly reliable, cost-efficient and maintenance-friendly system. PLC-based cryostat control offers some distinct advantages, especially for a robotic facility. Apart of temperature monitoring and control, the PLC also monitors the vacuum quality, the power supply and the status of the PCC coolers (compressor power consumption and temperature, pressure in the gas lines, etc.). Furthermore, it provides an alarming system and safe and reproducible procedures for automatic cool down and warm up. The communication between PLC and higher-level software takes place via the OPC-UA protocol, offering a simple to implement, yet very powerful interface. Finally, a touch-panel display on the PLC provides the operator with a user-friendly and robust

  4. Promoting microbiology education through the iGEM synthetic biology competition.

    Science.gov (United States)

    Kelwick, Richard; Bowater, Laura; Yeoman, Kay H; Bowater, Richard P

    2015-08-01

    Synthetic biology has developed rapidly in the 21st century. It covers a range of scientific disciplines that incorporate principles from engineering to take advantage of and improve biological systems, often applied to specific problems. Methods important in this subject area include the systematic design and testing of biological systems and, here, we describe how synthetic biology projects frequently develop microbiology skills and education. Synthetic biology research has huge potential in biotechnology and medicine, which brings important ethical and moral issues to address, offering learning opportunities about the wider impact of microbiological research. Synthetic biology projects have developed into wide-ranging training and educational experiences through iGEM, the International Genetically Engineered Machines competition. Elements of the competition are judged against specific criteria and teams can win medals and prizes across several categories. Collaboration is an important element of iGEM, and all DNA constructs synthesized by iGEM teams are made available to all researchers through the Registry for Standard Biological Parts. An overview of microbiological developments in the iGEM competition is provided. This review is targeted at educators that focus on microbiology and synthetic biology, but will also be of value to undergraduate and postgraduate students with an interest in this exciting subject area. © FEMS 2015. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  5. Characterization of the allergen Sol gem 2 from the fire ant venom, Solenopsis geminata

    Directory of Open Access Journals (Sweden)

    S Sukprasert

    2012-01-01

    Full Text Available Sol i 2 is a potent allergen in Solenopsis invicta venom, and most humans exhibit reactivity to it. The Sol gem 2 allergen found in the venom of the Thai tropical fire ant Solenopsis geminata was analysed in the present study. The protein was present in higher amounts than other proteins, as determined by SDS-PAGE, and presumably has allergenic properties similar to those of Sol i 2. Sol gem 2 molecular weight is 28 and 15 kDa, respectively, under non-reducing and reducing conditions, indicating that its native form is a dimer. LC-MS/MS analysis confirmed its similarity to Sol i 2. The mono/dimeric form of Sol gem 2 was determined to be relevant by proteomic approach and immunoblotting. An anti-Sol gem 2 antibody was produced in mice, with a titer greater than 1:800 according to the Western blotting analysis. The Sol gem 2-neutralising activity of this antibody was determined in crickets. The paralytic dose 50 (PD50 of crude S. geminata venom was elevated from 0.18 mg/g of body weight to more than 0.90 mg/g of body weight after preincubation with antibody at a ratio of 1:1. These results suggest that Sol gem 2 plays an important role in mediating the effects of the piperidine derivatives in the venom.

  6. An aging study of triple GEMs in Ar-CO sub 2

    CERN Document Server

    Guirl, L; May, J; Miyamoto, J; Shipsey, I

    2002-01-01

    An aging study was performed using triple GEMs and a print circuit board (PCB) with an intense X-ray radiation source. The GEM chamber consists of three identical GEMs and a large gas gain (6000) was shared by them. The chamber and its gas circulation line was carefully cleaned and constructed with stainless steel materials. The detector was irradiated continuously about 750 h without interruption until a large amount of charge was accumulated. A single-wire counter served as a monitoring device to check the beam and ambient conditions. The quality of the Ar-CO sub 2 gas was checked by gas chromatography and no measurable amount of hydrocarbons were found. 27 mC/mm sup 2 was accumulated with no noticeable degradation and no deposit or discoloration was found in an optical check.

  7. Gas Gain Measurement Of GEM-Foil In Argon-Carbon Dioxide Mixture

    International Nuclear Information System (INIS)

    Nguyen Ngoc Duy; Vuong Huu Tan; Le Hong Khiem

    2011-01-01

    Nuclear reaction measurement with radioactive beam at low energy plays an important role in nuclear astrophysics and nuclear structure. The trajectory of particle beams can be obtained by using an active gas target, multiple-sampling and tracking proportional chamber (MSTPC), as a proportional counter. Because of intensity of low energy radioactive beam, in the stellar reaction such as (α, p), (p, α), it is necessary to increase the gain for the counter. In this case, a gas electrons multiplier (GEM) foil will be used, so the proportional counter is called GEM-MSTPC. The efficient gas gain of GEM foils which relates to foil thickness and operating pressure was investigated with two type of the foils, 400 μm and 200 μm, in Argon (70%) + Carbon dioxide (30%) mixture. (author)

  8. Wits Post Graduate Symposium Poster - iGEM

    CSIR Research Space (South Africa)

    Millroy, L

    2010-08-01

    Full Text Available This document is a poster providing details of the 2010 International Genetically Engineered Machines (iGEM) competition. The origins of the competition, as well as criteria, judging, sponsors, topic and team, are briefly described....

  9. Studies of characteristics of triple GEM detector for the ALICE-TPC upgrade

    International Nuclear Information System (INIS)

    Patra, Rajendra Nath; Singaraju, R.N.; Ahammed, Z.; Nayak, T.K.; Biswas, S.

    2015-01-01

    Gas Electron Multiplier (GEM) is a novel gas detector in the field of radiation detection. GEM detectors have tremendous advantages over other types gas detectors like high rate handling capability with high efficiency and very low ion back flow (IBF). These detectors are most suitable for the use in the future experiments in high-energy proton-proton and heavy-ion collisions at the Large Hadron Collider (LHC) at CERN and Facility for Antiproton and Ion Research (FAIR) at GSI. A Large Ion Collider Experiment (ALICE) at the LHC is a dedicated experiment for the study of Quark Gluon Plasma (QGP). In few years, the data taking rate for Pb-Pb collisions will increase by 100 times to 50 KHz. The ALICE Time Projection Chamber (TPC) is the main tracking detector in ALICE. It is planned that by the year 2018, GEM detectors will replace the present readout planes of TPC. The goal of the present study is to characterize the GEM detector to achieve the performance goal of the TPC

  10. Metal-mediated gem-Difluoroallylation of N-Acylhydrazones: Highly Efficient Synthesis of a,a-Difluorohomoallylic Amines

    Institute of Scientific and Technical Information of China (English)

    YUE Xuyi; QIU Xiaolong; QING Fengling

    2009-01-01

    Indium-mediated gem-difluoroallylation of aldehyde-derived N-acylhydrazones 1a-1q and 4a-4g with 3-bromo-3,3-difluoropropene 2 afforded a,a-difluorohomoallylic hydrazides 3a-3q and 5a-5g in high yields, re-spectively. Functional groups such as nitro, phenolic hydroxyl, benzyloxy and even C=C bonds of a,fl-unsaturated aldehydes were compatible under this mild and operationally simple gem-difluoroallylic reaction condition. By means of substitution of Zn powder for indium, gem-difluoroallylation of ketone-derived N-acylhydrazones 6a-6d also provided the corresponding a,a-difluorohomoallylic hydrazides 7a-7d in medium yields. The N-N bond cleavage of the hydrazide 3a proceeded smoothly to give the corresponding primary gem-difluorohomoallylic amine 8, which could be converted to gem-difluoro-δ-substituted α,β-unsaturated lactam 11 via acryloylation fol-lowed by ring closing metathesis (RCM) reaction.

  11. Improved model of the Earth's gravitational field: GEM-T1

    International Nuclear Information System (INIS)

    Marsh, J.G.; Lerch, F.J.; Christodoulidis, D.C.

    1987-07-01

    Goddard Earth Model T1 (GEM-T1), which was developed from an analysis of direct satellite tracking observations, is the first in a new series of such models. GEM-T1 is complete to degree and order 36. It was developed using consistent reference parameters and extensive earth and ocean tidal models. It was simultaneously solved for gravitational and tidal terms, earth orientation parameters, and the orbital parameters of 580 individual satellite arcs. The solution used only satellite tracking data acquired on 17 different satellites and is predominantly based upon the precise laser data taken by third generation systems. In all, 800,000 observations were used. A major improvement in field accuracy was obtained. For marine geodetic applications, long wavelength geoidal modeling is twice as good as in earlier satellite-only GEM models. Orbit determination accuracy has also been substantially advanced over a wide range of satellites that have been tested

  12. Screening the Drug Sensitivity Genes Related to GEM and CDDP in the Lung Cancer Cell-lines

    Directory of Open Access Journals (Sweden)

    Chunyu YANG

    2009-10-01

    Full Text Available Background and objective Screening of small-cell lung cancer (SCLC and non-small cell lung cancer (NSCLC cell lines with gemcitabine hydrochloride (GEM and cisplatin (CDDP related to drug sensitivity gene might clarify the action mechanism of anti-cancer drugs and provide a new clue for overcoming drug resistance and the development of new anti-cancer drugs, and also provide theoretical basis for the clinical treatment of individual. Methods The drug sensitivity of CDDP and GEM in 4 SCLC cell lines and 6 NSCLC cell lines was determined using MTT colorimetric assay, while the cDNA macroarray was applied to detect the gene expression state related to drug sensitivity of 10 lung cancer cell line in 1 291, and the correlation between the two was analysized. Results There were 6 genes showing significant positive correlation (r≥0.632, P < 0.05 with GEM sensitivity; 45 genes positively related to CDDP; another 41 genes related to both GEM and CDDP (r≥± 0.4. Lung cancer with GEM and CDDP sensitivity of two types of drugs significantly related genes were Metallothinein (Signal transduction molecules, Cathepsin B (Organization protease B and TIMP1 (Growth factor; the GEM, CDDP sensitivity associated genes of lung cancer cell lines mainly distributed in Metallothinein, Cathepsin B, growth factor TIMP1 categories. Conclusion There existed drug-related sensitive genes of GEM, CDDP in SCLC and NSCLC cell lines; of these genes, Metallothinein, Cathepsin B and TIMP1 genes presented a significant positive correlation with GEM drug sensitivity, a significant negative correlation with CDDP drug sensitivity.

  13. SYNTHESIS AND POLYMERIZATION OF GEM-METHYL(VINYLBENZYL)TETRACHLOROCYCLOTRIPHOSPHAZENE

    NARCIS (Netherlands)

    BOSSCHER, G; VANDEGRAMPEL, JC

    A new styrene-substituted chlorocyclotriphosphazene, gem-methyl(vinylbenzyl) tetrachlorocyclotriphosphazene, has been prepared from vinylbenzylmagnesium chloride and hexachlorocyclotriphosphazene. The organosubstituted chlorocyclotriphosphazene has been used in radical homo- and copolymerization

  14. Analysis of unscrammed loss of flow and heat sink for PRISM with GEM

    International Nuclear Information System (INIS)

    Slovik, G.C.; Van Tuyle, G.J.; Kennett, R.J.

    1991-01-01

    The US Department of Energy is sponsoring an advanced liquid-metal reactor design by General Electric Company (GE) called PRISM. The intent is to design a reactor with passively safe responses to many operational and severe accidents. PRISM is under review at the US Nuclear Regulatory Commission for licensability with Brookhaven National Laboratory providing technical assistance. Recently, the PRISM design has been modified to include three gas expansion modules (GEMs) on its core periphery. The GEMs were added to quickly reduce the power (by inserting negative reactivity) during loss-of-flow events to curtail peak fuel and clad temperatures predicted in the previous design. The GEM prototypes have been tested at the Fast Flux Test Facility. The significance of the GEMs in PRISM is discussed in this paper through the evaluation of the unprotected loss of flow (ULOF) and loss of heat sink using the SSC code. It has been demonstrated in the past that SSC predicts results similar to GE and other liquid-metal reactor codes

  15. MeerLICHT and BlackGEM: custom-built telescopes to detect faint optical transients

    Science.gov (United States)

    Bloemen, Steven; Groot, Paul; Woudt, Patrick; Klein Wolt, Marc; McBride, Vanessa; Nelemans, Gijs; Körding, Elmar; Pretorius, Margaretha L.; Roelfsema, Ronald; Bettonvil, Felix; Balster, Harry; Bakker, Roy; Dolron, Peter; van Elteren, Arjen; Elswijk, Eddy; Engels, Arno; Fender, Rob; Fokker, Marc; de Haan, Menno; Hagoort, Klaas; de Hoog, Jasper; ter Horst, Rik; van der Kevie, Giel; Kozłowski, Stanisław; Kragt, Jan; Lech, Grzegorz; Le Poole, Rudolf; Lesman, Dirk; Morren, Johan; Navarro, Ramon; Paalberends, Willem-Jelle; Paterson, Kerry; Pawłaszek, Rafal; Pessemier, Wim; Raskin, Gert; Rutten, Harrie; Scheers, Bart; Schuil, Menno; Sybilski, Piotr W.

    2016-07-01

    We present the MeerLICHT and BlackGEM telescopes, which are wide-field optical telescopes that are currently being built to study transient phenomena, gravitational wave counterparts and variable stars. The telescopes have 65 cm primary mirrors and a 2.7 square degree field-of-view. The MeerLICHT and BlackGEM projects have different science goals, but will use identical telescopes. The first telescope, MeerLICHT, will be commissioned at Sutherland (South Africa) in the first quarter of 2017. It will co-point with MeerKAT to collect optical data commensurate with the radio observations. After careful analysis of MeerLICHT's performance, three telescopes of the same type will be commissioned in La Silla (Chile) in 2018 to form phase I of the BlackGEM array. BlackGEM aims at detecting and characterizing optical counterparts of gravitational wave events detected by Advanced LIGO and Virgo. In this contribution we present an overview of the science goals, the design and the status of the two projects.

  16. PET in cerebrovascular disease; PET bei zerebrovaskulaeren Erkrankungen

    Energy Technology Data Exchange (ETDEWEB)

    Herholz, K. [Neurologische Universitaetsklinik der Univ. Koeln (Germany)]|[Max-Planck-Institut fuer Neurologische Forschung, Koeln (Germany)

    1997-03-01

    Tissue viability is of particular interest in acute cerebral ischemia because it may be preserved if reperfusion can be achieved rapidly, e.g. by acute thrombolysis. Measurements of regional cerebral blood flow (CBF) and oxygen consumption by PET can assess tissue viability, and they have substantially increased our knowledge of th pathophysiology of ischemic stroke and the associated penumbra. Widerspread clinical application in acute stroke, however, is unlikely because of the large logistic and personnel resources required. In chronic cerebrovascular disease, measurement of regional CBF and glucose metabolism, which is usually coupled, provide detailed insights in disturbance of cortical function, e.g. due to deafferentiation, and contribute to differentiation of dementia types. Chronic misery perfusion, i.e. reduced perfusion that does not match the metabolic demand of the tissue, can be demonstrated by PET. It may be found in some patients with high-grade arterial stenoses. Less severe impairment of brain perfusion can be demonstrated by measurement of the cerebrovascular reserve capacity. The most frequent clinical situations can be assessed by less demanding procedures, e.g. by SPECT. In conclusion, PET has its role in cerebrovascular disease primarily within scientific studies, where high resolution and absolute quantitation of physiological variables are essential. (orig.). 65 refs. [Deutsch] Beim akuten ischaemischen Insult ist die Vitalitaet des Gewebes von besonderem Interesse, da sie durch rasche Reperfusion, z.B. durch Thrombolyse, erhalten bleiben kann. Messungen der zerebralen Durchblutung und des Sauerstoffumsatzes mittels PET geben darueber wesentliche Aufschluesse, und sie sind wichtig fuer das Verstaendnis der Pathophysiologie ischaemischer Infarkte und der Penumbra mit kritischer Perfusion beim Menschen. Ihre breitere Anwendung in der klinischen Patientenversorgung kommt allerdings wegen des hohen Aufwandes derzeit kaum in Betracht. Bei

  17. Development of triple GEM detector for a heavy ion physics experiment

    International Nuclear Information System (INIS)

    Bhardwaj, A.; Biswal, K.; Gupta, R.

    2015-01-01

    Building and testing of micro-pattern gas detector such as Gas Electron Multiplier (GEM) for several upcoming High-Energy Physics (HEP) experiment projects, is an advance area of research in the field of detector development. We have carried out the long-term stability test and the uniformity of the relative gain over a GEM detector. The method of long-term test and uniformity of the relative gain and the results are presented in this article

  18. Development and Evaluation of the Biogenic Emissions Inventory System (BEIS) Model v3.6

    Science.gov (United States)

    We have developed new canopy emission algorithms and land use data for BEIS v3.6. Simulations with BEIS v3.4 and BEIS v3.6 in CMAQ v5.0.2 are compared these changes to the Model of Emissions of Gases and Aerosols from Nature (MEGAN) and evaluated the simulations against observati...

  19. lumpGEM: Systematic generation of subnetworks and elementally balanced lumped reactions for the biosynthesis of target metabolites.

    Directory of Open Access Journals (Sweden)

    Meric Ataman

    2017-07-01

    Full Text Available In the post-genomic era, Genome-scale metabolic networks (GEMs have emerged as invaluable tools to understand metabolic capabilities of organisms. Different parts of these metabolic networks are defined as subsystems/pathways, which are sets of functional roles to implement a specific biological process or structural complex, such as glycolysis and TCA cycle. Subsystem/pathway definition is also employed to delineate the biosynthetic routes that produce biomass building blocks. In databases, such as MetaCyc and SEED, these representations are composed of linear routes from precursors to target biomass building blocks. However, this approach cannot capture the nested, complex nature of GEMs. Here we implemented an algorithm, lumpGEM, which generates biosynthetic subnetworks composed of reactions that can synthesize a target metabolite from a set of defined core precursor metabolites. lumpGEM captures balanced subnetworks, which account for the fate of all metabolites along the synthesis routes, thus encapsulating reactions from various subsystems/pathways to balance these metabolites in the metabolic network. Moreover, lumpGEM collapses these subnetworks into elementally balanced lumped reactions that specify the cost of all precursor metabolites and cofactors. It also generates alternative subnetworks and lumped reactions for the same metabolite, accounting for the flexibility of organisms. lumpGEM is applicable to any GEM and any target metabolite defined in the network. Lumped reactions generated by lumpGEM can be also used to generate properly balanced reduced core metabolic models.

  20. La Gemäldegalerie di Dresda. Evoluzione dal Settecento a fine Ottocento

    Directory of Open Access Journals (Sweden)

    Aloisia Marzotto Caotorta

    2015-12-01

    Full Text Available Since its foundation, the Gemäldegalerie (Old Masters Picture Gallery in Dresden has been considered one of the most magnificent picture galleries in Europe. Not only during the Augustan Age there was a keen interest in the arts, but also a strong understanding of the arts as a means of political power claims. In this context, the Gemäldegalerie was the most representative display of this phenomenon. This article aims to explore the complex role played by the galleries of royal and aristocratic residences in Saxony, concentrating on the Gemäldegalerie between the 18th and 19th centuries as a case study, as well as focusing on its impact on contemporary German literature.

  1. The development and evaluation of mini-GEMs - short, focused, online e-learning videos in geriatric medicine.

    Science.gov (United States)

    Garside, Mark J; Fisher, James M; Blundell, Adrian G; Gordon, Adam L

    2018-01-01

    Mini Geriatric E-Learning Modules (Mini-GEMs) are short, focused, e-learning videos on geriatric medicine topics, hosted on YouTube, which are targeted at junior doctors working with older people. This study aimed to explore how these resources are accessed and used. The authors analyzed the viewing data from 22 videos published over the first 18 months of the Mini-GEM project. We conducted a focus group of U.K. junior doctors considering their experiences with Mini-GEMS. The Mini-GEMs were viewed 10,291 times over 18 months, equating to 38,435 minutes of total viewing time. The average viewing time for each video was 3.85 minutes. Learners valued the brevity and focused nature of the Mini-GEMs and reported that they watched them in a variety of settings to supplement clinical experiences and consolidate learning. Watching the videos led to an increase in self-reported confidence in managing older patients. Mini-GEMs can effectively disseminate clinical teaching material to a wide audience. The videos are valued by junior doctors due to their accessibility and ease of use.

  2. The TOTEM T2 telescope based on triple-GEM chambers

    CERN Document Server

    Bagliesi, M G; Brucken, E; Cecchi, R; David, E; Garcia, F; Greco, V; Heino, J; Hilden, T; Kurvinen, K; Lauhakangas, R; Lami, S; Latino, G; Magazzu, G; Oliveri, E; Pedreschi, E; Ropelewski, L; Scribano, A; Spinella, F; Turini, N; van Stenis, M

    2010-01-01

    The TOTEM experiment at LHC has chosen the triple Gas Electron Multiplier (GEM) technology for its T2 telescope which will provide charged track reconstruction in the pseudorapidity range 5.3<|η|<6.5 and a fully inclusive trigger for inelastic events. GEMs are gas filled detectors which combine good spatial resolution with very high rate capability and a good resistance to radiation. Preliminary results of cosmic ray tests performed at CERN on final T2 modules before installation are here presented. Comparisons between real and simulated detector performance are also shown.

  3. The TOTEM T2 telescope based on triple-GEM chambers

    Energy Technology Data Exchange (ETDEWEB)

    Bagliesi, M.G., E-mail: mg.bagliesi@pi.infn.i [University of Siena and INFN Pisa (Italy); Berretti, M. [University of Siena and INFN Pisa (Italy); Brucken, E. [Helsinki (Finland); Cecchi, R. [University of Siena and INFN Pisa (Italy); David, E. [CERN, Geneva (Switzerland); Garcia, F. [Helsinki (Finland); Greco, V. [University of Siena and INFN Pisa (Italy); Heino, J.; Hilden, T.; Kurvinen, K.; Lauhakangas, R. [Helsinki (Finland); Lami, S.; Latino, G.; Magazzu, G.; Oliveri, E.; Pedreschi, E. [University of Siena and INFN Pisa (Italy); Ropelewski, L. [CERN, Geneva (Switzerland); Scribano, A.; Spinella, F.; Turini, N. [University of Siena and INFN Pisa (Italy)

    2010-05-21

    The TOTEM experiment at LHC has chosen the triple Gas Electron Multiplier (GEM) technology for its T2 telescope which will provide charged track reconstruction in the pseudorapidity range 5.3<|{eta}|<6.5 and a fully inclusive trigger for inelastic events. GEMs are gas filled detectors which combine good spatial resolution with very high rate capability and a good resistance to radiation. Preliminary results of cosmic ray tests performed at CERN on final T2 modules before installation are here presented. Comparisons between real and simulated detector performance are also shown.

  4. Proceedings of the GEM Collaboration Meeting

    International Nuclear Information System (INIS)

    Bojowald, J.; Ilieva, I.; Klimala, W.; Machner, H.; Razen, B.; Kliczewski, S.; Magiera, A.; Smyrski, J.; Roy, B.J.; Urban, J.

    1997-11-01

    The main subject of the GEM meeting were: meson production near threshold, mesic atoms, nuclear resonances, symmetry violation, light ions structure and interactions. Additionally some apparatus problems like electronic equipment and charged particle detector have been discussed. The volume contains copies of transparencies supplied by the authors which are not normal full texts of papers

  5. Financial recognition of material misstatement risks of listed companies on GEM

    OpenAIRE

    Jie Ming; Yicong Jiang

    2017-01-01

    Listed companies on GEM are characterized by strong innovation, great growth ability, high risks and high yields. Starting from these characteristics, this paper carries out analysis by using the financial indicators that are effective to recognize the material misstatement risks and easy to be acquired, and combines with the sample data with high material misstatement risks on GEM in 2012 to 2014 to test the significance of spss difference, and finds that the material misstatement company an...

  6. An intercomparison of biogenic emissions estimates from BEIS2 and BIOME: Reconciling the differences

    Energy Technology Data Exchange (ETDEWEB)

    Wilkinson, J.G. [Alpine Geophysics, Pittsburgh, PA (United States); Emigh, R.A. [Alpine Geophysics, Boulder, CO (United States); Pierce, T.E. [Atmospheric Characterization and Modeling Division/NOAA, Research Triangle Park, NC (United States)

    1996-12-31

    Biogenic emissions play a critical role in urban and regional air quality. For instance, biogenic emissions contribute upwards of 76% of the daily hydrocarbon emissions in the Atlanta, Georgia airshed. The Biogenic Emissions Inventory System-Version 2.0 (BEIS2) and the Biogenic Model for Emissions (BIOME) are two models that compute biogenic emissions estimates. BEIS2 is a FORTRAN-based system, and BIOME is an ARC/INFO{reg_sign} - and SAS{reg_sign}-based system. Although the technical formulations of the models are similar, the models produce different biogenic emissions estimates for what appear to be essentially the same inputs. The goals of our study are the following: (1) Determine why BIOME and BEIS2 produce different emissions estimates; (2) Attempt to understand the impacts that the differences have on the emissions estimates; (3) Reconcile the differences where possible; and (4) Present a framework for the use of BEIS2 and BIOME. In this study, we used the Coastal Oxidant Assessment for Southeast Texas (COAST) biogenics data which were supplied to us courtesy of the Texas Natural Resource Conservation Commission (TNRCC), and we extracted the BEIS2 data for the same domain. We compared the emissions estimates of the two models using their respective data sets BIOME Using TNRCC data and BEIS2 using BEIS2 data.

  7. GEM Detectors in the Experiments at e+e- Colliders in BINP

    CERN Document Server

    Maltsev, T V

    2017-01-01

    Micro-pattern gaseous detectors possess a high spatial resolution in tens micron scale together with high rate capability up to 107 cm-2s-1. In addition, they have all advantages of gaseous detectors, such as relatively low costs per unit area, the possibility to equip a large area as well as a high uniformity. Cascaded Gas Electron Multiplier (GEM) based detectors are used in the collider experiments at Budker Institute of Nuclear Physics (BINP), and they are being developed for a number of new projects. In this article the review of GEM based detectors for the tagging system of the KEDR experiment at the VEPP-4M collider and for the DEUTERON facility at the VEPP-3 storage ring is presented. The GEM detector application of the CMD-3 detector upgrade at the VEPP-2000 collider and the Super τ Factory detector are discussed.

  8. Study of long-term operation of triple-GEM detectors for the high rate environment in CMS

    CERN Document Server

    Merlin, Jeremie Alexandre

    2013-01-01

    The CMS GEM collaboration is working on the possible instrumentation of the high-eta region of the CMS Endcap with Gas Electron Multiplier (GEM) detectors, a technology capable to sustain the hostile environment that will be encountered at the high-luminosity LHC. To ensure the long-term operation of large triple-GEM detectors in the CMS experiment, we are performing a set of studies in order to measure and understand the aging effect of triple-GEM Muon chambers. The aging includes all the processes that lead to a significant degradation of the performances of the detector gain drop, non-uniformity, dark current, discharges and resolution loss. The project is focused on monitoring continuously the response of the detector when irradiated by a source of Cs 137 at CERN in the Gamma Irradiation Facility (GIF). Moreover, the new technology employed for stretching the GEM foils, so called NS2, introduces new, carefully chosen materials and components in the detectors. Outgassing tests are performed in order to va...

  9. Zeitlicher Verlauf der avaskulären Nekrose des Hüftkopfes bei Patienten mit Pemphigus vulgaris.

    Science.gov (United States)

    Balighi, Kamran; Daneshpazhooh, Maryam; Aghazadeh, Nessa; Saeidi, Vahide; Shahpouri, Farzam; Hejazi, Pardis; Chams-Davatchi, Cheyda

    2016-10-01

    Pemphigus vulgaris (PV) wird in der Regel mit systemischen Corticosteroiden und Immunsuppressiva behandelt. Avaskuläre Nekrose (AVN) des Hüftkopfes ist eine gut bekannte schwerere Komplikation einer Corticosteroid-Therapie. Die Charakteristika dieser schweren Komplikation bei PV sind nach wie vor unbekannt. Nicht kontrollierte, retrospektive Untersuchung aller PV-bedingten AVN-Fälle, die in einer iranischen Klinik für bullöse Autoimmunerkrankungen zwischen 1985 und 2013 diagnostiziert wurden. Anhand der Krankenakten von 2321 untersuchten PV-Patienten wurden 45 Fälle (1,93 %) von femoraler AVN identifiziert. Dreißig davon waren Männer. Das mittlere Alter bei der Diagnose der AVN betrug 47,4 ± 14,2 Jahre. Der mittlere Zeitraum zwischen der Diagnose des PV und dem Einsetzen der AVN lag bei 25,3 ± 18,3 Monaten. Mit Ausnahme von acht Fällen (17,8 %) setzte die AVN bei der Mehrheit der Patienten innerhalb von drei Jahren nach Diagnose des PV ein. Die mittlere kumulative Dosis von Prednisolon bei Patienten mit AVN betrug 13.115,8 ± 7041,1 mg. Zwischen der Prednisolon-Gesamtdosis und dem Zeitraum bis zum Einsetzen der AVN bestand eine starke Korrelation (p = 0,001). Bei Patienten mit Alendronateinnahme in der Vorgeschichte war dieser Zeitraum signifikant kürzer (p = 0,01). Die AVN ist eine schwere Komplikation einer Corticosteroid-Behandlung bei Patienten mit PV. Sie wird bei 2 % der Patienten beobachtet und tritt vor allem in den ersten drei Behandlungsjahren auf. Bei Patienten, die höhere Dosen von Prednisolon erhalten, setzt die AVN tendenziell früher ein. © 2016 Deutsche Dermatologische Gesellschaft (DDG). Published by John Wiley & Sons Ltd.

  10. Evaluation of a GEM and CAT-based detector for radiation therapy beam monitoring

    International Nuclear Information System (INIS)

    Brahme, A.; Danielsson, M.; Iacobaeus, C.; Ostling, J.; Peskov, V.; Wallmark, M.

    2000-01-01

    We are developing a radiation therapy beam monitor for the Karolinska Institute. This monitor will consist of two consecutive detectors confined in one gas chamber: a 'keV-photon detector', which will allow diagnostic quality visualization of the patient, and a 'MeV-photon detector', that will measure the absolute intensity of the therapy beam and its position with respect to the patient. Both detectors are based on highly radiation resistant gas and solid photon to electron converters, combined with GEMs and a CAT as amplification structures. We have performed systematic studies of the high-rate characteristics of the GEM and the CAT, as well as tested the electron transfer through these electron multipliers and various types of converters. The tests show that the GEM and the CAT satisfy all requirements for the beam monitoring system. As a result of these studies we successfully developed and tested a full section of the beam monitor equipped with a MeV-photon converter placed between the GEM and the CAT

  11. UMA PROSPOSTA DEDUTIVISTA PARA PRINCÍPIOS CONTÁBEIS

    OpenAIRE

    Paulo Schmidt

    2009-01-01

    A proposta deste estudo a apresentar um breve relato sobre a evolução do pensamento cientifico ocorrida na física com a substituição dos princípios contábeis e filosófico, desde a Antiguidade grega ate os dias de hoje, como forma de fundamentar o posicionamento contrario ao raciocínio indutivo para o estabelecimento de uma estrutura conceitual para a contabilidade e para o desenvolvimento dos princípios contábeis. Apos essa incursão pelo campo filosófico, será aduzido um dos trabalhos d...

  12. Vitex-agnus-castus-Extrakt (Ze 440 zur Symptombehandlung bei Frauen mit menstruellen Zyklusstörungen

    Directory of Open Access Journals (Sweden)

    Eltbogen R

    2015-01-01

    Full Text Available Ziel: Diese nichtinterventionelle Beobachtungsstudie (NIS wurde von Schweizer Gynäkologen und Allgemeinmedizinern im Rahmen der üblichen ärztlichen Grundversorgung durchgeführt. Das Ziel der NIS war es, die Wirksamkeit und Sicherheit von Vitex-agnus-castus-(VAC Extrakt (Ze 440: premens, Zeller Medical AG, Romanshorn, Schweiz bei Frauen, die unter menstruellen Zyklusstörungen wie Polymenorrhö, Oligomenorrhö oder Amenorrhö litten, zu untersuchen. Methode: Insgesamt 211 Patientinnen nahmen an dieser NIS teil. Symptome, die mit menstruellen Zyklusstörungen („menstrual cycle irregularities“ [MCIs] und der Menstruationsblutung in Verbindung stehen, wurden bei einer Erstuntersuchung („baseline visit“ [BV] und einer Kontrolluntersuchung („follow-up visit“ [FV] nach Behandlung mit VAC-Extrakt über einen Zeitraum von 3 aufeinanderfolgenden Menstruationszyklen beurteilt. Ergebnisse: Der Anteil der Patientinnen, bei denen eine Beschwerdefreiheit oder eine Besserung der MCIs (insgesamt und spezifischer Beschwerdebilder wie Polymenorrhö, Oligomenorrhö und Amenorrhö erzielt werden konnte, lag bei der FV bei 79–85 %. Bei Symptomen im Zusammenhang mit der Menstruationsblutung wie Dysmenorrhö, Zwischenblutungen, Hypermenorrhö, Menometrorrhagie, Ovulationsblutung, präoder postmenstrueller Blutung betrug der Anteil der Patientinnen, bei denen ein Rückgang oder eine Besserung festgestellt wurde, bei der FV zwischen 60 und 88 %. Von 53 Patientinnen, die bei der BV von einem unerfüllten Kinderwunsch berichteten, wurden 12 Frauen (23 % während der Behandlung mit VAC-Extrakt schwanger. Bei der FV waren 91 % der Ärzte und 92 % der Patientinnen mit den erzielten Behandlungsergebnissen „zufrieden“ oder „sehr zufrieden“ und 80 % der Patientinnen bestätigten, dass sie gerne mit der Behandlung mit VAC-Extrakt fortfahren wollen. Fazit: Diese Beobachtungsstudie im Bereich der ärztlichen Grundversorgung ergab, dass die Behandlung mit VAC

  13. Implementation of the P barANDA Planar-GEM tracking detector in Monte Carlo simulations

    Science.gov (United States)

    Divani Veis, Nazila; Ehret, Andre; Firoozabadi, Mohammad M.; Karabowicz, Radoslaw; Maas, Frank; Saito, Nami; Saito, Takehiko R.; Voss, Bernd; PANDA Gem-Tracker Subgroup

    2018-02-01

    The P barANDA experiment at FAIR will be performed to investigate different aspects of hadron physics using anti-proton beams interacting with a fixed nuclear target. The experimental setup consists of a complex series of detector components covering a large solid angle. A detector with a gaseous active media equipped with gas electron multiplier (GEM) technique will be employed to measure tracks of charged particles at forward direction in order to achieve a high momentum resolution. In this work, a full setup of the GEM tracking detector has been implemented in the P barANDA Monte Carlo simulation package (PandaRoot) based on the current technical and conceptual design, and the expected performance of the P barANDA GEM-tracking detector has been investigated. Furthermore, material-budget studies in terms of the radiation length of the P barANDA GEM-tracking detector have been made in order to investigate the effect of the detector materials and its associated structures to particle measurements.

  14. A new design using GEM-based technology for the CMS experiment

    Science.gov (United States)

    Ressegotti, M.

    2017-07-01

    The muon system of the Compact Muon Solenoid (CMS) experiment at the LHC is currently not instrumented for pseudorapidity higher than |η|> 2.4. The main challenges to the installation of a detector in that position are the high particle flux to be sustained, a high level of radiation, and the ability to accomodate a multilevel detector into the small available space (less than 30 cm). A new back-to-back configuration of a Gas Electron Multiplier (GEM) detector is presented with the aim of developing a compact, multi-layer GEM detector. It is composed of two independent stacked triple-GEM detectors, positioned with the anodes toward the outside and sharing the same cathode plane, which is located at the center of the chamber, to reduce the total detector's thickness. A first prototype has been produced and tested with an X-Ray source and muon beam. First results on its performance are presented.

  15. A new design using GEM-based technology for the CMS experiment

    CERN Document Server

    Ressegotti, Martina

    2017-01-01

    The muon system of the Compact Muon Solenoid (CMS) experiment at the LHC is currently not instrumented for pseudorapidity higher than abs(${\\eta}$)${ > 2.4}$. The main challenges to the installation of a detector in that position are the high particle flux to be sustained, a high level of radiation, and the ability to accomodate a multilevel detector into the small available space (less than 30 cm). A new back-to-back configuration of a Gas Electron Multiplier (GEM) detector is presented with the aim of developing a compact, multi-layer GEM detector. It is composed of two independent stacked triple-GEM detectors, positioned with the anodes toward the outside and sharing the same cathode plane, which is located at the center of the chamber, to reduce the total detector's thickness. A first prototype has been produced and tested with an X-Ray source and muon beam. First results on its performance are presented.

  16. Numerical Investigation on Electron and Ion Transmission of GEM-based Detectors

    Directory of Open Access Journals (Sweden)

    Bhattacharya Purba

    2018-01-01

    Full Text Available ALICE at the LHC is planning a major upgrade of its detector systems, including the TPC, to cope with an increase of the LHC luminosity after 2018. Different R&D activities are currently concentrated on the adoption of the Gas Electron Multiplier (GEM as the gas amplification stage of the ALICE-TPC upgrade version. The major challenge is to have low ion feedback in the drift volume as well as to ensure a collection of good percentage of primary electrons in the signal generation process. In the present work, Garfield simulation framework has been adopted to numerically estimate the electron transparency and ion backflow fraction of GEM-based detectors. In this process, extensive simulations have been carried out to enrich our understanding of the complex physical processes occurring within single, triple and quadruple GEM detectors. A detailed study has been performed to observe the effect of detector geometry, field configuration and magnetic field on the above mentioned characteristics.

  17. Numerical Investigation on Electron and Ion Transmission of GEM-based Detectors

    Science.gov (United States)

    Bhattacharya, Purba; Sahoo, Sumanya Sekhar; Biswas, Saikat; Mohanty, Bedangadas; Majumdar, Nayana; Mukhopadhyay, Supratik

    2018-02-01

    ALICE at the LHC is planning a major upgrade of its detector systems, including the TPC, to cope with an increase of the LHC luminosity after 2018. Different R&D activities are currently concentrated on the adoption of the Gas Electron Multiplier (GEM) as the gas amplification stage of the ALICE-TPC upgrade version. The major challenge is to have low ion feedback in the drift volume as well as to ensure a collection of good percentage of primary electrons in the signal generation process. In the present work, Garfield simulation framework has been adopted to numerically estimate the electron transparency and ion backflow fraction of GEM-based detectors. In this process, extensive simulations have been carried out to enrich our understanding of the complex physical processes occurring within single, triple and quadruple GEM detectors. A detailed study has been performed to observe the effect of detector geometry, field configuration and magnetic field on the above mentioned characteristics.

  18. Evolution und Funktionsvariabilität von bunodonten Molaren bei Primaten

    OpenAIRE

    Menz, Ulrike Maria (Doktor)

    2017-01-01

    In der vorliegenden Arbeit werden funktionale Details der Okklusion während der Mastikation bei ausgewählten fossilen und rezenten Primaten quantitativ vergleichend untersucht. Dazu wurden die Okklusionsflächen von antagonistischen Molarenpaaren mit modernen virtuellen Verfahren eingescannt und anhand von 3D Kronenmodellen kartiert und funktional ausgewertet. Die in der Forschergruppe DFG FOR 771 entwickelte Software „Occlusal Fingerprint Analyser“ (OFA) kam erstmals bei einer großen Stichpro...

  19. Energy resolution studies of an IROC GEM prototype for the ALICE TPC

    Energy Technology Data Exchange (ETDEWEB)

    Mathis, Andreas [TU Muenchen, Physik Department E12, Excellence Cluster ' ' Universe' ' , D-85748, Garching (Germany); Collaboration: ALICE-Collaboration

    2015-07-01

    The ALICE collaboration (A Large Ion Collider Experiment) is planning an upgrade of its central barrel detectors, to be able to cope with the increased LHC luminosity beyond 2018. In order to fully exploit the increase in collision rate to about 50 kHz in Pb-Pb, the TPC is foreseen to be operated in an ungated mode with continuous readout. This demands for a replacement of the currently used, gated MWPC by GEM-based readout chambers, while retaining the present tracking and particle identification capabilities of the TPC via measurement of the specific energy loss (dE/dx). The present baseline solution for the TPC upgrade consists of a stack of four large-sized GEM foils as amplification stage, containing both Standard (S, 140 μm) and Large Pitch (LP, 280 μm) GEM foils arranged in the order S-LP-LP-S. This arrangement has been proven as advantageous in terms of ion backflow and energy resolution. A prototype of an ALICE IROC (Inner Readout Chamber) was equipped with such a quadruple GEM stack, installed inside a field cage and exposed to a beam of electrons and pions from the CERN PS. The performance of the prototype in terms of energy resolution has been evaluated and is presented.

  20. Pilzinfektionen des Zentralnervensystems bei immunkompetentem Wirt

    NARCIS (Netherlands)

    Tintelnot, K.; de Hoog, G.S.; Haase, G.

    2014-01-01

    Die Mehrzahl von Pilzinfektionen, die zu mykotischen Tumoren führen und bei Patienten ohne jegliche prädisponierende Vorerkrankung auftreten, wird durch Cryptococcus gattii bzw. C. neoformans oder durch Schwärzepilze, insbesondere durch Cladophialophora bantiana, Ramichloridium mackenziei, Exophiala

  1. Study of gain variation as a function of physical parameters of GEM foil

    CERN Document Server

    Das, Supriya

    2015-01-01

    The ALICE experiment at LHC has planned to upgrade the TPC by replacing the MWPC with GEM based detecting elements to restrict the IBF to a tolerable value. However the variation of the gain as a function of physical parameters of industrially produced large size GEM foils is needed to be studied as a part of the QA procedure for the detector. The size of the electron avalanche and consequently the gain for GEM based detectors depend on the electric field distribution inside the holes. Geometry of a hole plays an important role in defining the electric field inside it. In this work we have studied the variation of the gain as a function of the hole diameters using Garfield++ simulation package.

  2. Kontrastmittelverstärkte Magnet-Resonanz-Urographie unter forcierter Diurese - Stellenwert in der Differentialdiagnostik bei Obstruktionen des oberen Harntraktes

    Directory of Open Access Journals (Sweden)

    Jung P

    2001-01-01

    Full Text Available Die Magnet-Resonanz-Urographie (MRU ist ein relativ neues Verfahren in der Diagnostik des oberen Harntraktes. Das Ziel dieser Studie war der Vergleich der Aussagefähigkeit der MRU unter Gabe von Gadolinium und Furosemid und dem konventionellen Urogramm (IVU in der Diagnostik der Ursache von Obstruktionen im Bereich des Harnleiters. 82 Patienten mit im IVU nachgewiesener Obstruktion des oberen Harntraktes oder urographisch stummer Niere bei sonographisch nachgewiesener Dilatation wurden der MRU zugeführt. Die Bilder beider Untersuchungsmethoden wurden von voneinander unabhängigen Untersuchern befundet. Zwei Urologen befundeten die IVU-Bilder, zwei Radiologen die MRU-Bilder, die Radiologen kannten die IVU-Diagnose nicht. Bei unklarer Diagnose wurden weitere Untersuchungen wie Computertomographie, retrograde Pyelographie oder Ureteroskopie durchgeführt. Die Diagnosen waren: Harnleitersteine bei 72 Patienten, Harnleitertumore bei 8 Patienten und extraureterale Tumore bei 2 Patienten. Eine richtige Diagnose bei den Steinpatienten wurde durch IVU bei 49 von 72 Patienten und durch MRU bei 64 von 72 Patienten gestellt. In dieser Patientengruppe wurden durch die MRU zwei falsche Diagnosen gestellt. Fehlende Kontrastmittelausscheidung war der Hauptgrund für Versagen der IVU. 3 der 8 Patienten mit Harnleitertumoren wurden durch die IVU richtig dignostiziert, bei dreien wurde eine falsche Diagnose gestellt. Durch die MRU konnten in dieser Gruppe 7 von 8 Patienten korrekt diagnostiziert werden, es wurde keine falsche Diagnose erhoben. IVU wird zunächst die Standarduntersuchungstechnik zur Darstellung des oberen Harntraktes bleiben, aber durch diese Studie konnte die Möglichkeit gezeigt werden, die in der MRU in Kombination mit Gadolinium und Furosemid liegt. Die größte Bedeutung dieser Untersuchung liegt in der urographisch stummen Niere, bei Untersuchungen in der Schwangerschaft, bei Kindern und bei Patienten mit Kontrastmittelunverträglichkeit.

  3. GEMS: Underwater spectrometer for long-term radioactivity measurements

    Energy Technology Data Exchange (ETDEWEB)

    Sartini, Ludovica, E-mail: ludovica.sartini@ingv.i [Istituto Nazionale di Geofisica e Vulcanologia (INGV), Sect.Roma 2, Roma (Italy); Genoa University, Genoa (Italy); Simeone, Francesco; Pani, Priscilla [' Sapienza' University and Istituto Nazionale di Fisica Nucleare (INFN), Sect.Roma, Roma (Italy); Lo Bue, Nadia; Marinaro, Giuditta [Istituto Nazionale di Geofisica e Vulcanologia (INGV), Sect.Roma 2, Roma (Italy); Grubich, Andry; Lobko, Alexander [Institute for Nuclear Problems (INP), Belarus State University, Minsk (Belarus); Etiope, Giuseppe [Istituto Nazionale di Geofisica e Vulcanologia (INGV), Sect.Roma 2, Roma (Italy); Capone, Antonio [' Sapienza' University and Istituto Nazionale di Fisica Nucleare (INFN), Sect.Roma, Roma (Italy); Favali, Paolo [Istituto Nazionale di Geofisica e Vulcanologia (INGV), Sect.Roma 2, Roma (Italy); Gasparoni, Francesco; Bruni, Federico [Tecnomare S.p.A., Venice (Italy)

    2011-01-21

    GEMS (Gamma Energy Marine Spectrometer) is a prototype of an autonomous radioactivity sensor for underwater measurements, developed in the framework for a development of a submarine telescope for neutrino detection (KM3NeT Design Study Project). The spectrometer is highly sensitive to gamma rays produced by {sup 40}K decays but it can detect other natural (e.g., {sup 238}U,{sup 232}Th) and anthropogenic radio-nuclides (e.g., {sup 137}Cs). GEMS was firstly tested and calibrated in the laboratory using known sources and it was successfully deployed for a long-term (6 months) monitoring at a depth of 3200 m in the Ionian Sea (Capo Passero, offshore Eastern Sicily). The instrument recorded data for the whole deployment period within the expected specifications. This monitoring provided, for the first time, a continuous time-series of radioactivity in deep-sea.

  4. Development of a GEM-based high rate TPC

    Energy Technology Data Exchange (ETDEWEB)

    Neubert, Sebastian; Hoeppner, Christian; Ketzer, Bernhard; Weitzel, Quirin; Paul, Stefan; Woerner, Lisa; Konorov, Igor; Mann, Alexander [Technische Universitaet Muenchen, Physik Department E18, Garching (Germany)

    2008-07-01

    A TPC is considered as the central tracker of the PANDA experiment, which is currently being planned at the new accelerator complex FAIR at Darmstadt. PANDA is designed as an internal target experiment at the antiproton storage ring HESR. The central tracker has to measure particle trajectories over a wide momentum range (0.1-8 GeV/c) from up to 2.10{sup 7} antiproton-proton annihilations/s. The continuous nature of the antiproton beam makes the use of a traditional ion gate impractical. Owing to their intrinsic ion suppression properties, GEM foils are planned as the amplification stage. A small prototype of this GEM-TPC (diameter 200 mm, drift length 77 mm) has been built and characterized with cosmic muons. Results such as spatial resolution, cluster distributions, and diffusion properties are presented in this talk.

  5. Development of a GEM-based TPC for PANDA

    Energy Technology Data Exchange (ETDEWEB)

    Hoeppner, Christian; Ketzer, Bernhard; Konorov, Igor; Mann, Alexander; Neubert, Sebastian; Paul, Stephan; Weitzel, Quirin; Woerner, Lisa [Technische Universitaet Muenchen, Physik Department E18, 85748 Garching (Germany)

    2008-07-01

    A TPC is considered as the central tracker of the PANDA experiment, which is currently being planned at the new accelerator complex FAIR at Darmstadt. PANDA is designed as an internal target experiment at the antiproton storage ring HESR. The central tracker has to measure particle trajectories over a wide momentum range (0.1-8 GeV/c) from up to 2.10{sup 7} antiproton-proton annihilations/s. The continuous nature of the antiproton beam makes the use of a traditional ion gate impractical. Owing to their intrinsic ion suppression properties, GEM foils are planned as the amplification stage. A small prototype of this GEM-TPC (diameter 200 mm, drift length 77 mm) has been built and characterized with cosmic muons. Results such as spatial resolution, cluster distributions, and diffusion properties are presented in this talk.

  6. A triple GEM gamma camera for medical application

    Energy Technology Data Exchange (ETDEWEB)

    Anulli, F. [Laboratori Nazionali di Frascati INFN, Frascati (Italy); Balla, A. [Laboratori Nazionali di Frascati INFN, Frascati (Italy); Bencivenni, G. [Laboratori Nazionali di Frascati INFN, Frascati (Italy); Corradi, G. [Laboratori Nazionali di Frascati INFN, Frascati (Italy); D' Ambrosio, C. [Laboratori Nazionali di Frascati INFN, Frascati (Italy); Domenici, D. [Laboratori Nazionali di Frascati INFN, Frascati (Italy); Felici, G. [Laboratori Nazionali di Frascati INFN, Frascati (Italy); Gatta, M. [Laboratori Nazionali di Frascati INFN, Frascati (Italy); Morone, M.C. [Dipartimento di Biopatologia e Diagnostica per immagini, Universita di Roma Tor Vergata (Italy); INFN - Sezione di Roma Tor Vergata (Italy); Murtas, F. [Laboratori Nazionali di Frascati INFN, Frascati (Italy)]. E-mail: fabrizio.murtas@lnf.infn.it; Schillaci, O. [Dipartimento di Biopatologia e Diagnostica per immagini, Universita di Roma Tor Vergata (Italy)

    2007-03-01

    A Gamma Camera for medical applications 10x10cm{sup 2} has been built using a triple GEM chamber prototype. The photon converters placed in front of the three GEM foils, has been realized with different technologies. The chamber, High Voltage supplied with a new active divider made in Frascati, is readout through 64 pads, 1mm{sup 2} wide, organized in a row of 8cm long, with LHCb ASDQ chip. This Gamma Camera can be used both for X-ray movie and PET-SPECT imaging; this chamber prototype is placed in a scanner system, creating images of 8x8cm{sup 2}. Several measurements have been performed using phantom and radioactive sources of Tc99m(140keV) and Na22(511keV). Results on spatial resolution and image reconstruction are presented.

  7. Simulation of space-charge effects in an ungated GEM-based TPC

    Energy Technology Data Exchange (ETDEWEB)

    Böhmer, F.V., E-mail: felix.boehmer@tum.de; Ball, M.; Dørheim, S.; Höppner, C.; Ketzer, B.; Konorov, I.; Neubert, S.; Paul, S.; Rauch, J.; Vandenbroucke, M.

    2013-08-11

    A fundamental limit to the application of Time Projection Chambers (TPCs) in high-rate experiments is the accumulation of slowly drifting ions in the active gas volume, which compromises the homogeneity of the drift field and hence the detector resolution. Conventionally, this problem is overcome by the use of ion-gating structures. This method, however, introduces large dead times and restricts trigger rates to a few hundred per second. The ion gate can be eliminated from the setup by the use of Gas Electron Multiplier (GEM) foils for gas amplification, which intrinsically suppress the backflow of ions. This makes the continuous operation of a TPC at high rates feasible. In this work, Monte Carlo simulations of the buildup of ion space charge in a GEM-based TPC and the correction of the resulting drift distortions are discussed, based on realistic numbers for the ion backflow in a triple-GEM amplification stack. A TPC in the future P{sup ¯}ANDA experiment at FAIR serves as an example for the experimental environment. The simulations show that space charge densities up to 65 fC cm{sup −3} are reached, leading to electron drift distortions of up to 10 mm. The application of a laser calibration system to correct these distortions is investigated. Based on full simulations of the detector physics and response, we show that it is possible to correct for the drift distortions and to maintain the good momentum resolution of the GEM-TPC.

  8. Simulation of space-charge effects in an ungated GEM-based TPC

    International Nuclear Information System (INIS)

    Böhmer, F.V.; Ball, M.; Dørheim, S.; Höppner, C.; Ketzer, B.; Konorov, I.; Neubert, S.; Paul, S.; Rauch, J.; Vandenbroucke, M.

    2013-01-01

    A fundamental limit to the application of Time Projection Chambers (TPCs) in high-rate experiments is the accumulation of slowly drifting ions in the active gas volume, which compromises the homogeneity of the drift field and hence the detector resolution. Conventionally, this problem is overcome by the use of ion-gating structures. This method, however, introduces large dead times and restricts trigger rates to a few hundred per second. The ion gate can be eliminated from the setup by the use of Gas Electron Multiplier (GEM) foils for gas amplification, which intrinsically suppress the backflow of ions. This makes the continuous operation of a TPC at high rates feasible. In this work, Monte Carlo simulations of the buildup of ion space charge in a GEM-based TPC and the correction of the resulting drift distortions are discussed, based on realistic numbers for the ion backflow in a triple-GEM amplification stack. A TPC in the future P ¯ ANDA experiment at FAIR serves as an example for the experimental environment. The simulations show that space charge densities up to 65 fC cm −3 are reached, leading to electron drift distortions of up to 10 mm. The application of a laser calibration system to correct these distortions is investigated. Based on full simulations of the detector physics and response, we show that it is possible to correct for the drift distortions and to maintain the good momentum resolution of the GEM-TPC

  9. Does GEM-Encoding Clinical Practice Guidelines Improve the Quality of Knowledge Bases? A Study with the Rule-Based Formalism

    Science.gov (United States)

    Georg, Gersende; Séroussi, Brigitte; Bouaud, Jacques

    2003-01-01

    The aim of this work was to determine whether the GEM-encoding step could improve the representation of clinical practice guidelines as formalized knowledge bases. We used the 1999 Canadian recommendations for the management of hypertension, chosen as the knowledge source in the ASTI project. We first clarified semantic ambiguities of therapeutic sequences recommended in the guideline by proposing an interpretative framework of therapeutic strategies. Then, after a formalization step to standardize the terms used to characterize clinical situations, we created the GEM-encoded instance of the guideline. We developed a module for the automatic derivation of a rule base, BR-GEM, from the instance. BR-GEM was then compared to the rule base, BR-ASTI, embedded within the critic mode of ASTI, and manually built by two physicians from the same Canadian guideline. As compared to BR-ASTI, BR-GEM is more specific and covers more clinical situations. When evaluated on 10 patient cases, the GEM-based approach led to promising results. PMID:14728173

  10. Does GEM-encoding clinical practice guidelines improve the quality of knowledge bases? A study with the rule-based formalism.

    Science.gov (United States)

    Georg, Georg; Séroussi, Brigitte; Bouaud, Jacques

    2003-01-01

    The aim of this work was to determine whether the GEM-encoding step could improve the representation of clinical practice guidelines as formalized knowledge bases. We used the 1999 Canadian recommendations for the management of hypertension, chosen as the knowledge source in the ASTI project. We first clarified semantic ambiguities of therapeutic sequences recommended in the guideline by proposing an interpretative framework of therapeutic strategies. Then, after a formalization step to standardize the terms used to characterize clinical situations, we created the GEM-encoded instance of the guideline. We developed a module for the automatic derivation of a rule base, BR-GEM, from the instance. BR-GEM was then compared to the rule base, BR-ASTI, embedded within the critic mode of ASTI, and manually built by two physicians from the same Canadian guideline. As compared to BR-ASTI, BR-GEM is more specific and covers more clinical situations. When evaluated on 10 patient cases, the GEM-based approach led to promising results.

  11. Financial recognition of material misstatement risks of listed companies on GEM

    Directory of Open Access Journals (Sweden)

    Jie Ming

    2017-11-01

    Full Text Available Listed companies on GEM are characterized by strong innovation, great growth ability, high risks and high yields. Starting from these characteristics, this paper carries out analysis by using the financial indicators that are effective to recognize the material misstatement risks and easy to be acquired, and combines with the sample data with high material misstatement risks on GEM in 2012 to 2014 to test the significance of spss difference, and finds that the material misstatement company and the normal company have significant difference in the profitability, solvency, growth ability and cash flow.

  12. Kulturspezifische Elemente und ihre Problematik bei der Filmsynchronisierung

    Directory of Open Access Journals (Sweden)

    Prof. Dr. Carmen Cuéllar Lázaro

    2013-07-01

    Full Text Available Bei der Untersuchung der Übersetzungsproblematik von kulturspezifischen Elementen geht es darum, diese Konzepte begrifflich abzugrenzen, inhaltlich und sprachlich zu klassifizieren sowie die Problematik ihrer Übersetzung zu beschreiben. Bei der Filmsynchronisierung sind außerdem die Merkmale und besonderen Bedingungen des Mediums und des audiovisuellen Textes zu berücksichtigen. Die Zielsetzung dieser Studie ist, die Übersetzung von kulturspezifischen Elementen der Filmsynchronisierung (Deutsch-Spanisch zu analysieren. Wir schlagen ein Zwei-Ebenen-Modell vor: Die erste Ebene berücksichtigt die Art der erfahrenen sprachlichen Bearbeitung. Auf der zweiten Ebene wird die kulturelle Orientierung der Ergebnisse untersucht. Danach werden einige Schlussfolgerungen aus der spanischen Synchronfassung gezogen.

  13. Kulturspezifische Elemente und ihre Problematik bei der Filmsynchronisierung

    Directory of Open Access Journals (Sweden)

    Prof. Dr. Carmen Cuéllar Lázaro

    2013-07-01

    Full Text Available Bei der Untersuchung der Übersetzungsproblematik von kulturspezifischen Elementen geht es darum, diese Konzepte begrifflich abzugrenzen, inhaltlich und sprachlich zu klassifizieren sowie die Problematik ihrer Übersetzung zu beschreiben. Bei der Filmsynchronisierung sind außerdem die Merkmale und besonderen Bedingungen des Mediums und des audiovisuellen Textes zu berücksichtigen.   Die Zielsetzung dieser Studie ist, die Übersetzung von kulturspezifischen Elementen der Filmsynchronisierung (Deutsch-Spanisch zu analysieren. Wir schlagen ein Zwei-Ebenen-Modell vor: Die erste Ebene berücksichtigt die Art der erfahrenen sprachlichen Bearbeitung. Auf der zweiten Ebene wird die kulturelle Orientierung der Ergebnisse untersucht. Danach werden einige Schlussfolgerungen aus der spanischen Synchronfassung gezogen.

  14. GPU Computing Gems Emerald Edition

    CERN Document Server

    Hwu, Wen-mei W

    2011-01-01

    ".the perfect companion to Programming Massively Parallel Processors by Hwu & Kirk." -Nicolas Pinto, Research Scientist at Harvard & MIT, NVIDIA Fellow 2009-2010 Graphics processing units (GPUs) can do much more than render graphics. Scientists and researchers increasingly look to GPUs to improve the efficiency and performance of computationally-intensive experiments across a range of disciplines. GPU Computing Gems: Emerald Edition brings their techniques to you, showcasing GPU-based solutions including: Black hole simulations with CUDA GPU-accelerated computation and interactive display of

  15. Building a large-area GEM-based readout chamber for the upgrade of the ALICE TPC

    CERN Document Server

    Gasik, Piotr

    2017-01-01

    A large Time Projection Chamber (TPC) is the main device for tracking and charged-particle identification in the ALICE experiment at the CERN LHC. After the second long shutdown in 2019-2020, the LHC will deliver Pb beams colliding at an interaction rate up to 50 kHz, which is about a factor of 100 above the present read-out rate of the TPC. To fully exploit the LHC potential the TPC will be upgraded based on the Gas Electron Multiplier (GEM) technology. A prototype of an ALICE TPC Outer Read-Out Chamber (OROC) was equipped with twelve large-size GEM foils as amplification stage to demonstrate the feasibility of replacing the current Multi Wire Proportional Chambers with the new technology. With a total area of $\\sim$0.76 m$^2$ it is the largest GEM-based detector built to date. The GEM OROC was installed within a test field cage and commissioned with radioactive sources.

  16. Building a large-area GEM-based readout chamber for the upgrade of the ALICE TPC

    Energy Technology Data Exchange (ETDEWEB)

    Gasik, P. [Physik Department E62, Technische Universität München, Garching (Germany); Excellence Cluster ‘Origin and Structure of the Universe’, Garching (Germany)

    2017-02-11

    A large Time Projection Chamber (TPC) is the main device for tracking and charged-particle identification in the ALICE experiment at the CERN LHC. After the second long shutdown in 2019–2020, the LHC will deliver Pb beams colliding at an interaction rate up to 50 kHz, which is about a factor of 100 above the present read-out rate of the TPC. To fully exploit the LHC potential the TPC will be upgraded based on the Gas Electron Multiplier (GEM) technology. A prototype of an ALICE TPC Outer Read-Out Chamber (OROC) was equipped with twelve large-size GEM foils as amplification stage to demonstrate the feasibility of replacing the current Multi Wire Proportional Chambers with the new technology. With a total area of ∼0.76 m{sup 2} it is the largest GEM-based detector built to date. The GEM OROC was installed within a test field cage and commissioned with radioactive sources.

  17. Building a large-area GEM-based readout chamber for the upgrade of the ALICE TPC

    International Nuclear Information System (INIS)

    Gasik, P.

    2017-01-01

    A large Time Projection Chamber (TPC) is the main device for tracking and charged-particle identification in the ALICE experiment at the CERN LHC. After the second long shutdown in 2019–2020, the LHC will deliver Pb beams colliding at an interaction rate up to 50 kHz, which is about a factor of 100 above the present read-out rate of the TPC. To fully exploit the LHC potential the TPC will be upgraded based on the Gas Electron Multiplier (GEM) technology. A prototype of an ALICE TPC Outer Read-Out Chamber (OROC) was equipped with twelve large-size GEM foils as amplification stage to demonstrate the feasibility of replacing the current Multi Wire Proportional Chambers with the new technology. With a total area of ∼0.76 m 2 it is the largest GEM-based detector built to date. The GEM OROC was installed within a test field cage and commissioned with radioactive sources.

  18. Detection and Imaging of High-Z Materials with a Muon Tomography Station Using GEM Detectors

    CERN Document Server

    Gnanvo, K; Bittner, W; Costa, F; Grasso, L; Hohlmann, M; Locke, J B; Martoiu, S; Muller, H; Staib, M; Tarazona, A; Toledo, J

    2010-01-01

    Muon tomography based on the measurement of multiple scattering of atmospheric cosmic ray muons is a promising technique for detecting and imaging heavily shielded high-Z nuclear materials such as enriched uranium. This technique could complement standard radiation detection portals currently deployed at international borders and ports, which are not very sensitive to heavily shielded nuclear materials. We image small targets in 3D using $2\\times 2 \\times 2$ mm^3 voxels with a minimal muon tomography station prototype that tracks muons with Gas Electron Multiplier (GEM) detectors read out in 2D with x-y microstrips of 400 micron pitch. With preliminary electronics, the GEM detectors achieve a spatial resolution of 130 microns in both dimensions. With the next GEM-based prototype station we plan to probe an active volume of ~27 liters. We present first results on reading out all 1536 microstrips of a $30 \\times 30$ cm^2 GEM detector for the next muon tomography prototype with final frontend electronics and DAQ...

  19. Resolution studies of a GEM-based TPC

    Energy Technology Data Exchange (ETDEWEB)

    Killenberg, M.

    2006-12-15

    Currently there are four different concept studies trying to optimise the detector for the requirements at the ILC. In three of these detector concepts a time projection chamber (TPC) is foreseen as the main tracking device. To achieve the intended spatial resolution of 100 {mu}m, micro pattern gas detectors (MPGD) are considered for gas amplification. The two different MPGDs discussed for the ILC TPC are Micro-Mesh Gaseous Detectors (Micromegas) and Gas Electron Multiplier foils (GEMs). The current thesis shows resolution studies with a TPC prototype equipped with a triple GEM readout structure. A hodoscope made up of silicon strip sensors gives a precision reference track, allowing an unbiased measurement of the spatial resolution. High statistics measurements have been conducted at the DESY test beam facility, which provides positrons with a tunable energy between 1 GeV and 6 GeV. Using the independent measurement of the hodoscope allows systematic studies of the homogeneity of the TPC's electric field. The fluctuations of the field in the chamber's central region were found to be {delta}E/E=8.10{sup -3}. Field distortions have been determined and corrected, reducing the remaining deviations to a level well below the spatial resolution of the TPC. One important task is to reduce the number of ions drifting back into the sensitive volume. Special GEM settings with minimised ion backdrift have been examined with respect to their influence on the spatial resolution and it was found that the spatial resolution is not degraded using these special settings. The TPC prototype has been operated in a 4 T magnetic field, provided by a superconducting solenoid located at DESY Hamburg. Again the spatial resolution measured with the ion backdrift optimised settings is compared to that achieved with nonoptimised settings. In both cases the measured resolution is approximately 130 {mu}m. (orig.)

  20. Resolution studies of a GEM-based TPC

    International Nuclear Information System (INIS)

    Killenberg, M.

    2006-01-01

    Currently there are four different concept studies trying to optimise the detector for the requirements at the ILC. In three of these detector concepts a time projection chamber (TPC) is foreseen as the main tracking device. To achieve the intended spatial resolution of 100 μm, micro pattern gas detectors (MPGD) are considered for gas amplification. The two different MPGDs discussed for the ILC TPC are Micro-Mesh Gaseous Detectors (Micromegas) and Gas Electron Multiplier foils (GEMs). The current thesis shows resolution studies with a TPC prototype equipped with a triple GEM readout structure. A hodoscope made up of silicon strip sensors gives a precision reference track, allowing an unbiased measurement of the spatial resolution. High statistics measurements have been conducted at the DESY test beam facility, which provides positrons with a tunable energy between 1 GeV and 6 GeV. Using the independent measurement of the hodoscope allows systematic studies of the homogeneity of the TPC's electric field. The fluctuations of the field in the chamber's central region were found to be ΔE/E=8.10 -3 . Field distortions have been determined and corrected, reducing the remaining deviations to a level well below the spatial resolution of the TPC. One important task is to reduce the number of ions drifting back into the sensitive volume. Special GEM settings with minimised ion backdrift have been examined with respect to their influence on the spatial resolution and it was found that the spatial resolution is not degraded using these special settings. The TPC prototype has been operated in a 4 T magnetic field, provided by a superconducting solenoid located at DESY Hamburg. Again the spatial resolution measured with the ion backdrift optimised settings is compared to that achieved with nonoptimised settings. In both cases the measured resolution is approximately 130 μm. (orig.)

  1. Effects of spin-orbit coupling on laser cooling of BeI and MgI

    Energy Technology Data Exchange (ETDEWEB)

    Wan, Mingjie, E-mail: wanmingjie1983@sina.com; Huang, Duohui; Shao, Juxiang; Li, Yuanyuan [Computational Physics Key Laboratory of Sichuan Province, Yibin University, Yibin 644007 (China); Yu, You [College of Optoelectronic Technology, Chengdu University of Information Technology, Chengdu 610225 (China); Li, Song [College of Physical Science and Technology, Yangtze University, Jingzhou 434023 (China)

    2015-10-28

    We present the ab initio study of spin-orbit coupling effects on laser cooling of BeI and MgI molecules. Potential energy curves for the X{sup 2}Σ{sup +}{sub 1/2}, A{sup 2}Π{sub 1/2,3/2}, and 2{sup 2}Π{sub 3/2,1/2} states are calculated using multi-reference configuration interaction method plus Davidson corrections. Spectroscopic parameters of BeI and MgI are in excellent agreement with available experimental and theoretical values. The A{sup 2}Π{sub 3/2} state of MgI is a repulsive state. It is an unsuitable scheme for the A{sup 2}Π{sub 3/2}(υ′)← X{sup 2}Σ{sup +}{sub 1/2} (υ″) transition for laser cooling of MgI. Highly diagonally distributed Franck-Condon factors f{sub 00} for the A{sup 2}Π{sub 1/2,3/2} (υ′ = 0) ← X{sup 2}Σ{sup +}{sub 1/2} (υ″ = 0) transitions and suitable radiative lifetimes τ for the A{sup 2}Π{sub 1/2,3/2} (υ′ = 0) of BeI and MgI are obtained. Three laser wavelength drives are required for the A{sup 2}Π{sub 1/2,3/2}(υ′)←X{sup 2}Σ{sup +}{sub 1/2} (υ″) transitions of BeI and MgI. The proposed cooling wavelengths of BeI and MgI are both in the violet region. The results imply the feasibility of laser cooling of BeI and MgI, and that laser cooling of BeI is more possible.

  2. Nagelbefall kann bei Patienten mit Psoriasis auf eine Enthesiopathie hinweisen.

    Science.gov (United States)

    Castellanos-González, Maria; Joven, Beatriz Esther; Sánchez, Julio; Andrés-Esteban, Eva María; Vanaclocha-Sebastián, Francisco; Romero, Pablo Ortiz; Díaz, Raquel Rivera

    2016-11-01

    Obwohl subklinische Enthesiopathie ein gut etabliertes diagnostisches Merkmal der Psoriasisarthritis (PsA) ist, wird sie häufig übersehen, da viele Patienten asymptomatisch sind. Gäbe es klinische Hinweise auf das Vorliegen einer Enthesiopathie, würde dies den Klinikern die Möglichkeit eröffnen, eine PsA frühzeitig zu diagnostizieren. Es wurde eine monozentrische prospektive Studie mit insgesamt 90 Psoriasis-Patienten durchgeführt, um mittels Ultraschall das Vorliegen von Enthesenanomalien zu untersuchen und eine Korrelation mit dem Befall der Nägel festzustellen. Enthesenanomalien wurden bei 23 Patienten (25,5 %) gefunden, von denen 19 (82,6 %) Nagelbefall aufwiesen. Bei 4 Patienten waren die Nägel nicht betroffen. Enthesiopathie lag bei 31,1 % (19/61) der Patienten mit Onychopathie vor, von den Patienten ohne Nagelbefall litten nur 13,8 % (4/29) an Enthesiopathie (p = 0,07). Zwischen dem Target-NAPSI-Score und dem Vorliegen einer Enthesiopathie bestand eine signifikante Korrelation. Eine signifikante Korrelation bestand darüber hinaus auch zwischen dem Vorliegen einer Enthesiopathie und der Anzahl der betroffenen Nägel (p = 0,035). Klinische Belege für eine Onychopathie können der Schlüssel für die frühe Diagnose einer Enthesiopathie bei Psoriasis-Patienten sein. © 2016 Deutsche Dermatologische Gesellschaft (DDG). Published by John Wiley & Sons Ltd.

  3. The Mitochondrial GTPase Gem1 Contributes to the Cell Wall Stress Response and Invasive Growth of Candida albicans

    Directory of Open Access Journals (Sweden)

    Barbara Koch

    2017-12-01

    Full Text Available The interactions of mitochondria with the endoplasmic reticulum (ER are crucial for maintaining proper mitochondrial morphology, function and dynamics. This enables cells to utilize their mitochondria optimally for energy production and anabolism, and it further provides for metabolic control over developmental decisions. In fungi, a key mechanism by which ER and mitochondria interact is via a membrane tether, the protein complex ERMES (ER-Mitochondria Encounter Structure. In the model yeast Saccharomyces cerevisiae, the mitochondrial GTPase Gem1 interacts with ERMES, and it has been proposed to regulate its activity. Here we report on the first characterization of Gem1 in a human fungal pathogen. We show that in Candida albicans Gem1 has a dominant role in ensuring proper mitochondrial morphology, and our data is consistent with Gem1 working with ERMES in this role. Mitochondrial respiration and steady state cellular phospholipid homeostasis are not impacted by inactivation of GEM1 in C. albicans. There are two major virulence-related consequences of disrupting mitochondrial morphology by GEM1 inactivation: C. albicans becomes hypersusceptible to cell wall stress, and is unable to grow invasively. In the gem1Δ/Δ mutant, it is specifically the invasive capacity of hyphae that is compromised, not the ability to transition from yeast to hyphal morphology, and this phenotype is shared with ERMES mutants. As a consequence of the hyphal invasion defect, the gem1Δ/Δ mutant is drastically hypovirulent in the worm infection model. Activation of the mitogen activated protein (MAP kinase Cek1 is reduced in the gem1Δ/Δ mutant, and this function could explain both the susceptibility to cell wall stress and lack of invasive growth. This result establishes a new, respiration-independent mechanism of mitochondrial control over stress signaling and hyphal functions in C. albicans. We propose that ER-mitochondria interactions and the ER

  4. The Mitochondrial GTPase Gem1 Contributes to the Cell Wall Stress Response and Invasive Growth of Candida albicans.

    Science.gov (United States)

    Koch, Barbara; Tucey, Timothy M; Lo, Tricia L; Novakovic, Stevan; Boag, Peter; Traven, Ana

    2017-01-01

    The interactions of mitochondria with the endoplasmic reticulum (ER) are crucial for maintaining proper mitochondrial morphology, function and dynamics. This enables cells to utilize their mitochondria optimally for energy production and anabolism, and it further provides for metabolic control over developmental decisions. In fungi, a key mechanism by which ER and mitochondria interact is via a membrane tether, the protein complex ERMES (ER-Mitochondria Encounter Structure). In the model yeast Saccharomyces cerevisiae , the mitochondrial GTPase Gem1 interacts with ERMES, and it has been proposed to regulate its activity. Here we report on the first characterization of Gem1 in a human fungal pathogen. We show that in Candida albicans Gem1 has a dominant role in ensuring proper mitochondrial morphology, and our data is consistent with Gem1 working with ERMES in this role. Mitochondrial respiration and steady state cellular phospholipid homeostasis are not impacted by inactivation of GEM1 in C. albicans . There are two major virulence-related consequences of disrupting mitochondrial morphology by GEM1 inactivation: C. albicans becomes hypersusceptible to cell wall stress, and is unable to grow invasively. In the gem1 Δ / Δ mutant, it is specifically the invasive capacity of hyphae that is compromised, not the ability to transition from yeast to hyphal morphology, and this phenotype is shared with ERMES mutants. As a consequence of the hyphal invasion defect, the gem1 Δ / Δ mutant is drastically hypovirulent in the worm infection model. Activation of the mitogen activated protein (MAP) kinase Cek1 is reduced in the gem1 Δ / Δ mutant, and this function could explain both the susceptibility to cell wall stress and lack of invasive growth. This result establishes a new, respiration-independent mechanism of mitochondrial control over stress signaling and hyphal functions in C. albicans . We propose that ER-mitochondria interactions and the ER-Mitochondria Organizing

  5. GEM System: automatic prototyping of cell-wide metabolic pathway models from genomes

    Directory of Open Access Journals (Sweden)

    Nakayama Yoichi

    2006-03-01

    Full Text Available Abstract Background Successful realization of a "systems biology" approach to analyzing cells is a grand challenge for our understanding of life. However, current modeling approaches to cell simulation are labor-intensive, manual affairs, and therefore constitute a major bottleneck in the evolution of computational cell biology. Results We developed the Genome-based Modeling (GEM System for the purpose of automatically prototyping simulation models of cell-wide metabolic pathways from genome sequences and other public biological information. Models generated by the GEM System include an entire Escherichia coli metabolism model comprising 968 reactions of 1195 metabolites, achieving 100% coverage when compared with the KEGG database, 92.38% with the EcoCyc database, and 95.06% with iJR904 genome-scale model. Conclusion The GEM System prototypes qualitative models to reduce the labor-intensive tasks required for systems biology research. Models of over 90 bacterial genomes are available at our web site.

  6. Quality of the spare triple-GEM detectors

    CERN Document Server

    Lenci, Rosario; Paoletti, Emiliano; Pasquali, Luigi; Pinci, Davide; Piscitelli, Carmelo; Poli Lener, Marco; Sciubba, Adalberto; Tskhadadze, Edisher

    2017-01-01

    Triple-GEM chambers equip the inner region of the M1 muon station. In order to provide spare detectors in case of problems in the operating ones, new chambers have been assembled at the Frascati National Laboratories of the INFN. This note summarizes the results of the quality tests performed at the end of the production procedure.

  7. PET in diagnosing exocrine pancreatic cancer; PET bei Tumoren des exokrinen Pankreas

    Energy Technology Data Exchange (ETDEWEB)

    Bares, R.; Besenfelder, H.; Dohmen, B.M. [Abt. Nuklearmedizin, Radiologische Klinik des Universitaetsklinikums Tuebingen (Germany)

    2003-06-01

    Despite dramatic improvements in diagnostic imaging (ultrasonography, in particular endoscopic ultrasound, CT, MRI) treatment results of pancreatic cancer are still poor. Due to the lack of early symptoms, most tumors are diagnosed at an advanced stage of disease which excludes curative surgical treatment. FDG-PET has been shown to be effective in detecting pancreatic cancer as well as differentiating benign from malignant pancreatic tumors. Results might be further improved by applying quantitative analyses, in particular kinetic modelling of FDG metabolism. Nevertheless false negative as well as false positive findings may occur. Small lesions (lymphnode or liver metastases < 1 cm) might be missed, furthermore hyperglycemia often present in patients with pancreatic disease might reduce tumor uptake and subsequently tumor detectability by PET. False positive findings were reported in active pancreatitis and some benign tumors. Although PET proved to be superior to CT or ERCP in detecting cancer, clinical relevance of PET is limited due to the absence of therapeutic consequences to be derived from PET. As a consequence PET should only be used in patients with equivocal findings of morphological imaging (CT, ERCP) who are potential candidates for surgical treatment. (orig.) [German] Trotz verbesserter diagnostischer Moeglichkeiten (endoskopischer Ultraschall, Spiral-CT, MRT) sind die Behandlungsergebnisse bei Tumoren des exokrinen Pankreas nach wie vor unbefriedigend. Aufgrund der spaet einsetzenden klinischen Symptomatik wird die Diagnose meist erst bei lokaler Inoperabilitaet gestellt. Die FDG-PET has sich sowohl im Nachweis von Pankreaskarzinomen als auch bei der Differenzialdiagnose pankreatischer Raumforderungen bewaehrt und den etablierten bildgebenden Verfahren (Ultraschall, CT) als ueberlegen erwiesen. Weitere Verbesserungen erscheinen durch absolute Quantifizierung der FDG-Kinetik moeglich. Dennoch koennen falsch negative wie auch falsch positive Ergebnisse

  8. Deoxygenative gem-difluoroolefination of carbonyl compounds with (chlorodifluoromethyltrimethylsilane and triphenylphosphine

    Directory of Open Access Journals (Sweden)

    Fei Wang

    2014-02-01

    Full Text Available Background: 1,1-Difluoroalkenes cannot only be used as valuable precursors for organic synthesis, but also act as bioisosteres for enzyme inhibitors. Among various methods for their preparation, the carbonyl olefination with difluoromethylene phosphonium ylide represents one of the most straightforward methods.Results: The combination of (chlorodifluoromethyltrimethylsilane (TMSCF2Cl and triphenylphosphine (PPh3 can be used for the synthesis of gem-difluoroolefins from carbonyl compounds. Comparative experiments demonstrate that TMSCF2Cl is superior to (bromodifluoromethyltrimethylsilane (TMSCF2Br and (trifluoromethyltrimethylsilane (TMSCF3 in this reaction.Conclusion: Similar to many other Wittig-type gem-difluoroolefination reactions in the presence of PPh3, the reaction of TMSCF2Cl with aldehydes and activated ketones is effective.

  9. Use of laser induced breakdown spectroscopy in the determination of gem provenance: beryls

    International Nuclear Information System (INIS)

    McManus, Catherine E.; McMillan, Nancy J.; Harmon, Russell S.; Whitmore, Robert C.; De Lucia, Frank C. Jr.; Miziolek, Andrzej W.

    2008-01-01

    The provenance of gem stones has been of interest to geologists, gemologists, archeologists, and historians for centuries. Laser induced breakdown spectroscopy (LIBS) provides a minimally destructive tool for recording the rich chemical signatures of gem beryls (aquamarine, goshenite, heliodor, and morganite). Broadband LIBS spectra of 39 beryl (Be3Al2Si6O18) specimens from 11 pegmatite mines in New Hampshire, Connecticut, and Maine (USA) are used to assess the potential of using principal component analysis of LIBS spectra to determine specimen provenance. Using this technique, beryls from the three beryl-bearing zones in the Palermo no. 1 pegmatite (New Hampshire) can be recognized. However, the compositional variation within this single mine is comparable to that in beryls from all three states. Thus, a very large database with detailed location metadata will be required to routinely determine gem beryl provenance

  10. Design and implementation of the infrastructure of HadGEM3: the next-generation Met Office climate modelling system

    Directory of Open Access Journals (Sweden)

    H. T. Hewitt

    2011-04-01

    Full Text Available This paper describes the development of a technically robust climate modelling system, HadGEM3, which couples the Met Office Unified Model atmosphere component, the NEMO ocean model and the Los Alamos sea ice model (CICE using the OASIS coupler. Details of the coupling and technical solutions of the physical model (HadGEM3-AO are documented, in addition to a description of the configurations of the individual submodels. The paper demonstrates that the implementation of the model has resulted in accurate conservation of heat and freshwater across the model components. The model performance in early versions of this climate model is briefly described to demonstrate that the results are scientifically credible. HadGEM3-AO is the basis for a number of modelling efforts outside of the Met Office, both within the UK and internationally. This documentation of the HadGEM3-AO system provides a detailed reference for developers of HadGEM3-based climate configurations.

  11. MR spectroscopy in dementia; MR-Spektroskopie bei Demenz

    Energy Technology Data Exchange (ETDEWEB)

    Hauser, T.; Gerigk, L.; Giesel, F.; Schuster, L.; Essig, M. [Deutsches Krebsforschungszentrum (DKFZ) Heidelberg, Abteilung E010, Radiologie, Heidelberg (Germany)

    2010-09-15

    With an increasingly aging population we are faced with the problem of an increasing number of dementia patients. In addition to clinical, neuropsychological and laboratory procedures, MRI plays an important role in the early diagnosis of dementia. In addition to various morphological changes functional changes can also help in the diagnosis and differential diagnosis of dementia. Overall the diagnosis of dementia can be improved by using parameters from MR spectroscopy. This article focuses on MR spectroscopic changes in the physiological aging process as well as on changes in mild cognitive impairment a precursor of Alzheimer's dementia, in Alzheimer's dementia, frontotemporal dementia, vascular dementia and Lewy body dementia. (orig.) [German] Angesichts einer immer aelter werdenden Bevoelkerung sind wir mit dem Problem einer zunehmenden Zahl an Demenzerkrankungen konfrontiert. Neben klinischen, neuropsychologischen und laborchemischen Verfahren spielt die MRT zur Fruehdiagnostik einer Demenz eine wichtige Rolle. Morphologische Veraenderungen wie auch verschiedene funktionelle Verfahren helfen bei der Diagnostik und Differenzialdiagnostik einer Demenz. Insgesamt kann mittels MR-spektroskopischer Parameter die Diagnostik einer Demenz verbessert werden. In diesem Artikel soll auf MR-spektroskopische Veraenderungen im Rahmen des physiologischen Alterungsprozesses eingegangen werden. Ferner werden speziell Veraenderungen bei leichter kognitiver Beeintraechtigung, einer Vorform der Alzheimer-Demenz, bei Alzheimer-, frontotemporaler, vaskulaerer und Lewy-Koerper-Demenz eroertert. (orig.)

  12. Behandlung von Herzrhythmusstörungen mit Magnesium bei Patienten mit Herzinsuffizienz

    Directory of Open Access Journals (Sweden)

    Wink K

    2002-01-01

    Full Text Available Die medikamentöse Behandlung von Herzrhythmusstörungen ist unbefriedigend, da bei guter Wirksamkeit durch die Proarrhythmie eine Verbesserung der Prognose gefährdet und nicht gesichert ist. Man kann davon ausgehen, daß Magnesiumsalze keine arrhythmogene Effekte aufweisen. Bei Patienten mit einer Herzinsuffizienz besteht häufig ein Mg-Mangel, der durch gastrointestinale Störungen, neurohormonale Regulationen, aber auch durch die Therapie (Diuretika,Digitalisbedingt ist. An Patienten mit einer Herzinsuffizienz müßte sich demnach zeigen lassen, ob die Mg-Substitution einen antiarrhythmischen Effekt aufweist. In fünf placebokontrollierten Studien konnte gezeigt werden, daß sich teil weise signifikant und mit ausreichen der Aussagekraft (PowerArrhythmien bei Patienten mit Herzinsuffizienz durch orale und parenterale Gabe von Mg-Salzen reduzieren lassen. Trotz Einschränkungen wie z.B. inadäquates Design, fehlende Vermeidung von Bias, ungenügende Vergleichbarkeit der Behandlungsgruppen, inadäquate Auswertung und ungenügende Berücksichtigung der Spontanvariation läßt sich aufgrund der Ergebnisse der Studien die Hypothese aufstellen, daß Magnesiumsalze bei Patienten mit Herzinsuffizienz Herzrhythmusstörungen günstig beeinflussen können. Prospektive, randomisierte,verblindete und kontrollierte konfirmatorische Studien mit ausreichenden Fallzahlen sind jedoch notwendig, um diese Hypothese zu bestätigen.

  13. Secondary scintillation yield from GEM and THGEM gaseous electron multipliers for direct dark matter search

    Science.gov (United States)

    Monteiro, C. M. B.; Fernandes, L. M. P.; Veloso, J. F. C. A.; Oliveira, C. A. B.; dos Santos, J. M. F.

    2012-07-01

    The search for alternatives to PMTs as photosensors in optical TPCs for rare event detection has significantly increased in the last few years. In particular, in view of the next generation large volume detectors, the use of photosensors with lower natural radioactivity, such as large area APDs or GM-APDs, with the additional possibility of sparse surface coverage, triggered the intense study of secondary scintillation production in micropattern electron multipliers, such as GEMs and THGEMs, as alternatives to the commonly used uniform electric field region between two parallel meshes. The much higher scintillation output obtained from the electron avalanches in such microstructures presents an advantage in those situations. The accurate knowledge of the amount of such scintillation is important for correct detector simulation and optimization. It will also serve as a benchmark for software tools developed and/or under development for the calculation of the amount of such scintillation.The secondary scintillation yield, or electroluminescence yield, in the electron avalanches of GEMs and THGEMs operating in gaseous xenon and argon has been determined for different gas pressures. At 1 bar, THGEMs deliver electroluminescence yields that are more than one order of magnitude higher when compared to those achieved in GEMs and two orders of magnitude when compared to those achieved in a uniform field gap. The THGEM electroluminescence yield presents a faster decrease with pressure when comparing to the GEM electroluminescence yield, reaching similar values to what is achieved in GEMs for xenon pressures of 2.5 bar, but still one order of magnitude higher than that produced in a uniform field gap. Another exception is the GEM operating in argon, which presents an electroluminescence yield similar to that produced in a uniform electric field gap, while the THGEM achieves yields that are more than one order of magnitude higher.

  14. Advances in Trace Element “Fingerprinting” of Gem Corundum, Ruby and Sapphire, Mogok Area, Myanmar

    Directory of Open Access Journals (Sweden)

    F. Lin Sutherland

    2014-12-01

    Full Text Available Mogok gem corundum samples from twelve localities were analyzed for trace element signatures (LA-ICP-MS method and oxygen isotope values (δ18O, by laser fluorination. The study augmented earlier findings on Mogok gem suites that suggested the Mogok tract forms a high vanadium gem corundum area and also identified rare alluvial ruby and sapphire grains characterised by unusually high silicon, calcium and gallium, presence of noticeable boron, tin and niobium and very low iron, titanium and magnesium contents. Oxygen isotope values (δ18O for the ruby and high Si-Ca-Ga corundum (20‰–25‰ and for sapphire (10‰–20‰ indicate typical crustal values, with values >20‰ being typical of carbonate genesis. The high Si-Ca-Ga ruby has high chromium (up to 3.2 wt % Cr and gallium (up to 0. 08 wt % Ga compared to most Mogok ruby (<2 wt % Cr; <0.02 wt % Ga. In trace element ratio plots the Si-Ca-Ga-rich corundum falls into separate fields from the typical Mogok metamorphic fields. The high Ga/Mg ratios (46–521 lie well within the magmatic range (>6, and with other features suggest a potential skarn-like, carbonate-related genesis with a high degree of magmatic fluid input The overall trace element results widen the range of different signatures identified within Mogok gem corundum suites and indicate complex genesis. The expanded geochemical platform, related to a variety of metamorphic, metasomatic and magmatic sources, now provides a wider base for geographic typing of Mogok gem corundum suites. It allows more detailed comparisons with suites from other deposits and will assist identification of Mogok gem corundum sources used in jewelry.

  15. "Updates to Model Algorithms & Inputs for the Biogenic Emissions Inventory System (BEIS) Model"

    Science.gov (United States)

    We have developed new canopy emission algorithms and land use data for BEIS. Simulations with BEIS v3.4 and these updates in CMAQ v5.0.2 are compared these changes to the Model of Emissions of Gases and Aerosols from Nature (MEGAN) and evaluated the simulations against observatio...

  16. Study of the spatial resolution of low-material GEM tracking detectors

    Directory of Open Access Journals (Sweden)

    Kudryavtsev V.N.

    2018-01-01

    Full Text Available The spatial resolution of GEM based tracking detectors has been simulated and measured. The simulation includes the GEANT4 based transport of high energy electrons with careful accounting for atomic relaxation processes including emission of fluorescent photons and Auger electrons and custom post-processing, including accounting for diffusion, gas amplification fluctuations, the distribution of signals on readout electrodes, electronics noise and a particular algorithm of the final coordinate calculation (center of gravity. The simulation demonstrates that a minimum of the spatial resolution of about 10 μm can be achieved with strip pitches from 250 μm to 300 μm. For larger pitches the resolution is quickly degrading reaching 80-100 μm at a pitch of 500 μm. The spatial resolution of low-material triple-GEM detectors for the DEUTRON facility at the VEPP-3 storage ring is measured at the extracted beam facility of the VEPP-4M collider. The amount of material in these detectors is reduced by etching the copper of the GEMs electrodes and using a readout structure on a thin kapton foil rather than on a glass fibre plate. The exact amount of material in one DEUTRON detector is measured by studying multiple scattering of 100 MeV electrons in it. The result of these measurements is X/X0 = 2.4×10−3 corresponding to a thickness of the copper layers of the GEM foils of 3 μm. The spatial resolution of one DEUTRON detector is measured with 500 MeV electrons and the measured value is equal to 35 ± 1 μm for orthogonal tracks.

  17. Study of the spatial resolution of low-material GEM tracking detectors

    Science.gov (United States)

    Kudryavtsev, V. N.; Maltsev, T. V.; Shekhtman, L. I.

    2018-02-01

    The spatial resolution of GEM based tracking detectors has been simulated and measured. The simulation includes the GEANT4 based transport of high energy electrons with careful accounting for atomic relaxation processes including emission of fluorescent photons and Auger electrons and custom post-processing, including accounting for diffusion, gas amplification fluctuations, the distribution of signals on readout electrodes, electronics noise and a particular algorithm of the final coordinate calculation (center of gravity). The simulation demonstrates that a minimum of the spatial resolution of about 10 μm can be achieved with strip pitches from 250 μm to 300 μm. For larger pitches the resolution is quickly degrading reaching 80-100 μm at a pitch of 500 μm. The spatial resolution of low-material triple-GEM detectors for the DEUTRON facility at the VEPP-3 storage ring is measured at the extracted beam facility of the VEPP-4M collider. The amount of material in these detectors is reduced by etching the copper of the GEMs electrodes and using a readout structure on a thin kapton foil rather than on a glass fibre plate. The exact amount of material in one DEUTRON detector is measured by studying multiple scattering of 100 MeV electrons in it. The result of these measurements is X/X0 = 2.4×10-3 corresponding to a thickness of the copper layers of the GEM foils of 3 μm. The spatial resolution of one DEUTRON detector is measured with 500 MeV electrons and the measured value is equal to 35 ± 1 μm for orthogonal tracks.

  18. A Muon Tomography Station with GEM Detectors for Nuclear Threat Detection

    Science.gov (United States)

    Staib, Michael; Gnanvo, Kondo; Grasso, Leonard; Hohlmann, Marcus; Locke, Judson; Costa, Filippo; Martoiu, Sorin; Muller, Hans

    2011-10-01

    Muon tomography for homeland security aims at detecting well-shielded nuclear contraband in cargo and imaging it in 3D. The technique exploits multiple scattering of atmospheric cosmic ray muons, which is stronger in dense, high-Z nuclear materials, e.g. enriched uranium, than in low-Z and medium-Z shielding materials. We have constructed and operated a compact Muon Tomography Station (MTS) that tracks muons with six to ten 30 cm x 30 cm Triple Gas Electron Multiplier (GEM) detectors placed on the sides of a 27-liter cubic imaging volume. The 2D strip readouts of the GEMs achieve a spatial resolution of ˜130 μm in both dimensions and the station is operated at a muon trigger rate of ˜20 Hz. The 1,536 strips per GEM detector are read out with the first medium-size implementation of the Scalable Readout System (SRS) developed specifically for Micro-Pattern Gas Detectors by the RD51 collaboration at CERN. We discuss the performance of this MTS prototype and present experimental results on tomographic imaging of high-Z objects with and without shielding.

  19. A Cylindrical GEM Detector with Analog Readout for the BESIII Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Cibinetto, G. [BESIII CGEM group, INFN Ferrara (Italy)

    2015-07-01

    Inner Trackers (IT) are key detectors in Particle Physics experiments; excellent spatial resolution, radiation transparency and hardness, and operability under high occupancies are main requirements. We aim to design, build and commission by 2017 a Cylindrical GEM (CGEM) detector candidate to be the new IT of the BESIII spectrometer, hosted on BEPC2 in IHEP, Beijing; BESIII data taking will last until at least 2020. The IT itself will represent an evolution w.r.t. the state of the art of GEM detectors, since the use of new kind of mechanical supports for the GEM foils will reduce the total radiation length of the detector and improve its tracking performance; an innovative design of the CGEM anode will allow for smaller capacitance and hence for bigger signals. The relatively strong BESIII magnetic field requires a new analogue readout; full custom front-end electronics, including a dedicated ASIC, will be designed and produced for optimal data collection. Prototype Beam Test results showing the measurement of the spatial resolution in a 1 Tesla magnetic field will be presented among with the mechanical design and simulations. (authors)

  20. Entrepreneurship in Ireland 2012: global entrepreneurship monitor (GEM)

    OpenAIRE

    Fitzsimons, Paula; O'Gorman, Colm

    2013-01-01

    Report on entrepreneurship in Ireland in the year 2012. Data used is the Global Entrepreneurship Monitor (GEM) data for Ireland and selected comparative countries. The report profiles entrepreneurs, reports on the rate of entrepreneurship in Ireland, discusses female entrepreneurship, and positions these results in the context of Irish entrepreneurship policy.

  1. Idealized climate change simulations with a high-resolution physical model: HadGEM3-GC2

    Science.gov (United States)

    Senior, Catherine A.; Andrews, Timothy; Burton, Chantelle; Chadwick, Robin; Copsey, Dan; Graham, Tim; Hyder, Pat; Jackson, Laura; McDonald, Ruth; Ridley, Jeff; Ringer, Mark; Tsushima, Yoko

    2016-06-01

    Idealized climate change simulations with a new physical climate model, HadGEM3-GC2 from The Met Office Hadley Centre are presented and contrasted with the earlier MOHC model, HadGEM2-ES. The role of atmospheric resolution is also investigated. The Transient Climate Response (TCR) is 1.9 K/2.1 K at N216/N96 and Effective Climate Sensitivity (ECS) is 3.1 K/3.2 K at N216/N96. These are substantially lower than HadGEM2-ES (TCR: 2.5 K; ECS: 4.6 K) arising from a combination of changes in the size of climate feedbacks. While the change in the net cloud feedback between HadGEM3 and HadGEM2 is relatively small, there is a change in sign of its longwave and a strengthening of its shortwave components. At a global scale, there is little impact of the increase in atmospheric resolution on the future climate change signal and even at a broad regional scale, many features are robust including tropical rainfall changes, however, there are some significant exceptions. For the North Atlantic and western Europe, the tripolar pattern of winter storm changes found in most CMIP5 models is little impacted by resolution but for the most intense storms, there is a larger percentage increase in number at higher resolution than at lower resolution. Arctic sea-ice sensitivity shows a larger dependence on resolution than on atmospheric physics.

  2. Spatial resolution studies of a GEM-TPC

    Energy Technology Data Exchange (ETDEWEB)

    Berger, Martin [TU Muenchen, 85748 Garching (Germany); Collaboration: GEM-TPC-Collaboration

    2015-07-01

    A GEM-TPC can exploit the intrinsic suppression of back drifting ions from the amplification stage of the GEM (Gas Electron Multiplier) foils to overcome the problem of drift-field distortions in an ungated operation. To explore the possibility of such a continuously running TPC (Time Projection Chamber) a large-size detector was built. This detector, with a drift length of 728 mm and a radius of 308 mm and a total of 10254 electronic channels, was designed as an upgrade for the FOPI experiment at GSI (Darmstadt, Germany) to improve the secondary vertex resolution especially for K{sup 0}{sub S}- and Λ-reconstruction and the PID capabilities. After commissioning a large statistics of cosmic data and beam-target reactions has been collected and the obtained tracks in the TPC have been used to improve the tracking algorithms. During the track finding and fitting procedure a clustering algorithm which takes into account the track topology as well as the full 3D spatial information is employed. The the clustering algorithm, the cluster error calculation and the tracking resolution are discussed in this contribution.

  3. A GEM readout with radial zigzag strips and linear charge-sharing response

    Science.gov (United States)

    Zhang, Aiwu; Hohlmann, Marcus; Azmoun, Babak; Purschke, Martin L.; Woody, Craig

    2018-04-01

    We study the position sensitivity of radial zigzag strips intended to read out large GEM detectors for tracking at future experiments. Zigzag strips can cover a readout area with fewer strips than regular straight strips while maintaining good spatial resolution. Consequently, they can reduce the number of required electronic channels and related cost for large-area GEM detector systems. A non-linear relation between incident particle position and hit position measured from charge sharing among zigzag strips was observed in a previous study. We significantly reduce this non-linearity by improving the interleaving of adjacent physical zigzag strips. Zigzag readout structures are implemented on PCBs and on a flexible foil and are tested using a 10 cm × 10 cm triple-GEM detector scanned with a strongly collimated X-ray gun on a 2D motorized stage. Angular resolutions of 60-84 μrad are achieved with a 1.37 mrad angular strip pitch at a radius of 784 mm. On a linear scale this corresponds to resolutions below 100 μm.

  4. MRI for myocarditis; MRT bei Myokarditis

    Energy Technology Data Exchange (ETDEWEB)

    Gutberlet, M.; Luecke, C.; Krieghoff, C.; Hildebrand, L.; Steiner, J.; Adam, J.; Grotthoff, M.; Lehmkuhl, L. [Herzzentrum, Universitaet Leipzig, Abteilung fuer Diagnostische und Interventionelle Radiologie, Leipzig (Germany); Lurz, P.; Eitel, I.; Thiele, H. [Herzzentrum, Universitaet Leipzig, Abteilung Kardiologie, Leipzig (Germany)

    2013-01-15

    Cardiovascular magnetic resonance imaging (CMRI) has become the primary tool for the non-invasive assessment in patients with suspected myocarditis, especially after exclusion of acute coronary syndrome (ACS) for the differential diagnosis. Various MRI parameters are available which have different accuracies. Volumetric and functional ventricular assessment and the occurrence of pericardial effusion alone demonstrate only a poor sensitivity and specificity. The calculation of the T2-ratio (edema assessment), the early or global relative myocardial enhancement (gRE) and the late gadolinium enhancement (LGE), which represents irreversibly injured myocardium, are more specific parameters. All MRI parameters demonstrate the best accuracy in infarct-like acute myocarditis, whereas in chronic myocarditis sensitivity and specificity are less accurate. Therefore, a multisequential (at least two out of three parameters are positive) approach is recommended. The assessment of the value of newer, more quantitative MRI sequences, such as T1 and T2-mapping is still under investigation. (orig.) [German] Die kardiale MRT stellt die primaere nichtinvasive bildgebende Modalitaet bei Verdacht auf Myokarditis dar, insbesondere auch nach Ausschluss eines akuten Koronarsyndroms (ACS) zur Differenzialdiagnose. Verschiedene MR-Parameter mit unterschiedlicher Wertigkeit stehen zur Verfuegung. Die Beurteilung der Volumetrie und Ventrikelfunktion weisen ebenso wie der Nachweis eines Perikardergusses alleine nur eine geringe Sensitivitaet und Spezifitaet auf. Die spezifischeren MRT-Inflammationsparameter stellen die T2-Ratio (Oedemnachweis), die fruehe Kontrastmittelanreicherung bzw. das globale relative Enhancement (gRE) und die spaete Kontrastmittelanreicherung, das so genannte Late-Gadolinium-Enhancement (LGE) als Zeichen eines irreversiblen Myokardschadens dar. Alle MR-Parameter zeigen die beste diagnostische Genauigkeit bei einer ''infarktaehnlichen'' akuten

  5. Radiotherapy for treatment of induratio penis plastica; Strahlentherapie bei Induratio penis plastica

    Energy Technology Data Exchange (ETDEWEB)

    Bruns, F.; Kardels, B.; Schaefer, U.; Schoenekaes, K.; Willich, N. [Westfaelische Wilhelms-Univ., Muenster (Germany). Klinik und Poliklinik fuer Strahlentherapie-Radioonkologie

    1999-06-01

    Radiotherapy is shown to be an effective, low-cost and non-invasive modality for treatment of induratio penis plastica. Its efficiency could be proven especially for inflammatory stages of the disease, or as an alternative after failure of conventional treatment. A total dose of no more than 20-25 Gy was found to achieve clear improvements in two thirds of the patients treated, while avoiding at the same time cosmetically disadvantageous late effects. (orig./CB) [Deutsch] Die Strahlentherapie ist eine wirksame, kostenguenstige und nicht-invasive Behandlungsmoeglichkeit bei Induratio penis plastica. Ihren Stellenwert konnte sie insbesondere im inflammatorischen Stadium und nach Versagen anderer konservativer Therapieansaetze zeigen. Eine Gesamteinstrahldosis von 20-25 Gy reicht aus, um bei 2/3 der Patienten eine deutliche Besserung der Symptomatik zu erzielen bei gleichzeitiger Vermeidung kosmetisch relevanter Spaetnebenwirkungen. (orig.)

  6. Untersuchungen zum Riechvermögen bei Patienten mit schizophrenen Störungen

    OpenAIRE

    Minovi, A; Dombrowski, T; Brüne, M; Dazert, S; Juckel, G

    2014-01-01

    Einleitung: Riechstörungen werden bei Patienten mit einer Schizophrenie in vielen Studien beschrieben. Im Rahmen einer prospektiv angelegten Studie untersuchten wir das Riechvermögen von 18 Patienten mit einer Schizophrenie im Vergleich zu einer Kontrollgruppe (n=13). Weiterhin erfolgte eine immunhistochemische Untersuchung der Riechschleimhaut bei 8 Patienten mit einer Schizophrenie.Methoden: Die Riechprüfung erfolgte mit Hilfe der erweiterten Sniffin' Sticks-Testbatterie. Nach Biopsie der...

  7. GEM: a dynamic tracking model for mesoscale eddies in the ocean

    Science.gov (United States)

    Li, Qiu-Yang; Sun, Liang; Lin, Sheng-Fu

    2016-12-01

    The Genealogical Evolution Model (GEM) presented here is an efficient logical model used to track dynamic evolution of mesoscale eddies in the ocean. It can distinguish between different dynamic processes (e.g., merging and splitting) within a dynamic evolution pattern, which is difficult to accomplish using other tracking methods. To this end, the GEM first uses a two-dimensional (2-D) similarity vector (i.e., a pair of ratios of overlap area between two eddies to the area of each eddy) rather than a scalar to measure the similarity between eddies, which effectively solves the "missing eddy" problem (temporarily lost eddy in tracking). Second, for tracking when an eddy splits, the GEM uses both "parent" (the original eddy) and "child" (eddy split from parent) and the dynamic processes are described as the birth and death of different generations. Additionally, a new look-ahead approach with selection rules effectively simplifies computation and recording. All of the computational steps are linear and do not include iteration. Given the pixel number of the target region L, the maximum number of eddies M, the number N of look-ahead time steps, and the total number of time steps T, the total computer time is O(LM(N + 1)T). The tracking of each eddy is very smooth because we require that the snapshots of each eddy on adjacent days overlap one another. Although eddy splitting or merging is ubiquitous in the ocean, they have different geographic distributions in the North Pacific Ocean. Both the merging and splitting rates of the eddies are high, especially at the western boundary, in currents and in "eddy deserts". The GEM is useful not only for satellite-based observational data, but also for numerical simulation outputs. It is potentially useful for studying dynamic processes in other related fields, e.g., the dynamics of cyclones in meteorology.

  8. GEM-E3: A computable general equilibrium model applied for Switzerland

    International Nuclear Information System (INIS)

    Bahn, O.; Frei, C.

    2000-01-01

    The objectives of the European Research Project GEM-E3-ELITE, funded by the European Commission and coordinated by the Centre for European Economic Research (Germany), were to further develop the general equilibrium model GEM-E3 (Capros et al., 1995, 1997) and to conduct policy analysis through case studies. GEM-E3 is an applied general equilibrium model that analyses the macro-economy and its interaction with the energy system and the environment through the balancing of energy supply and demand, atmospheric emissions and pollution control, together with the fulfillment of overall equilibrium conditions. PSI's research objectives within GEM-E3-ELITE were to implement and apply GEM-E3 for Switzerland. The first objective required in particular the development of a Swiss database for each of GEM-E3 modules (economic module and environmental module). For the second objective, strategies to reduce CO 2 emissions were evaluated for Switzerland. In order to develop the economic, PSI collaborated with the Laboratory of Applied Economics (LEA) of the University of Geneva and the Laboratory of Energy Systems (LASEN) of the Federal Institute of Technology in Lausanne (EPFL). The Swiss Federal Statistical Office (SFSO) and the Institute for Business Cycle Research (KOF) of the Swiss Federal Institute of Technology (ETH Zurich) contributed also data. The Swiss environmental database consists mainly of an Energy Balance Table and of an Emission Coefficients Table. Both were designed using national and international official statistics. The Emission Coefficients Table is furthermore based on know-how of the PSI GaBE Project. Using GEM-E3 Switzerland, two strategies to reduce the Swiss CO 2 emissions were evaluated: a carbon tax ('tax only' strategy), and the combination of a carbon tax with the buying of CO 2 emission permits ('permits and tax' strategy). In the first strategy, Switzerland would impose the necessary carbon tax to achieve the reduction target, and use the tax

  9. A PHOTOMETRIC STUDY OF THE ALGOL-TYPE BINARY FG Gem

    International Nuclear Information System (INIS)

    Zhang, J.; Qian, S.-B.

    2013-01-01

    High-quality three-color light curves of the binary FG Gem were measured and analyzed. A new method based on extensive searching of isochrones was used to investigate possible parameters for the binary. FG Gem is found to be an Algol-type semi-detached binary system with a primary star temperature of 8200 K and a mass ratio of 0.41(1). The correctness and reliability of our result requires the verification of precision spectroscopy or standard star observations. We investigate a new possible cause for the orbital period variations based on times of minimum light data. It is suggested from the quantitative analysis that variations in the orbital period can be explained by intermittent mass transfer and angular momentum loss from stellar winds leaving the system on rotating magnetic fields.

  10. A FPGA-based signal processing unit for a GEM array detector

    International Nuclear Information System (INIS)

    Yen, W.W.; Chou, H.P.

    2013-06-01

    in the present study, a signal processing unit for a GEM one-dimensional array detector is presented to measure the trajectory of photoelectrons produced by cosmic X-rays. The present GEM array detector system has 16 signal channels. The front-end unit provides timing signals from trigger units and energy signals from charge sensitive amplifies. The prototype of the processing unit is implemented using commercial field programmable gate array circuit boards. The FPGA based system is linked to a personal computer for testing and data analysis. Tests using simulated signals indicated that the FPGA-based signal processing unit has a good linearity and is flexible for parameter adjustment for various experimental conditions (authors)

  11. Die Rolle von RANK-Ligand und Osteoprotegerin bei Osteoporose

    Directory of Open Access Journals (Sweden)

    Hofbauer LC

    2004-01-01

    Full Text Available Receptor activator of nuclear factor (NF- κB ligand (RANKL, sein zellulärer Rezeptor RANK und der Decoy-Rezeptor Osteoprotegerin (OPG stellen ein essentielles Zytokinsystem für die Zellbiologie von Osteoklasten dar. Verschiedene Untersuchungen belegen die Bedeutung von Störungen des OPG/RANKL/RANK-Systems bei der Pathogenese metabolischer Knochenerkrankungen. In dieser Arbeit werden die wichtigsten Störungen des OPG/RANKL/RANK-Systems bei verschiedenen Osteoporoseformen dargestellt. Östrogenrezeptor- (ER- Agonisten wie 17 β-Östradiol, Raloxifen und Genistein stimulieren die osteoblastäre Produktion von OPG durch Aktivierung von ER- α in vitro, während Lymphozyten von Patientinnen mit Östrogenmangel RANKL überexprimieren. Die parenterale Gabe von OPG vermag den mit Östrogenmangel assoziierten Knochenverlust im Tiermodell und in einer kleineren klinischen Studie zu verhindern. Glukokortikoide und Immunsuppressiva steigern gleichzeitig die RANKL-Expression und hemmen die OPG-Produktion in osteoblastären Zellen in vitro. Glukokortikoide sind auch in vivo imstande, die OPG-Serumspiegel deutlich zu reduzieren. Dagegen hemmen biomechanische Reize in vitro die RANKL-Produktion und steigern die OPG-Produktion. Ein Fehlen dieser biomechanischen Reize bei längerer Immobilisierung kann daher den RANKL/OPG-Quotienten steigern, während die tierexperimentelle Immobilisierungs-Osteoporose durch die parenterale Gabe von OPG gemildert werden kann.

  12. Precise orbit determination and point positioning using GPS, Glonass, Galileo and BeiDou

    Directory of Open Access Journals (Sweden)

    Tegedor J.

    2014-04-01

    Full Text Available State of the art Precise Point Positioning (PPP is currently based on dual-frequency processing of GPS and Glonass navigation systems. The International GNSS Service (IGS is routinely providing the most accurate orbit and clock products for these constellations, allowing point positioning at centimeter-level accuracy. At the same time, the GNSS landscape is evolving rapidly, with the deployment of new constellations, such as Galileo and BeiDou. The BeiDou constellation currently consists of 14 operational satellites, and the 4 Galileo In-Orbit Validation (IOV satellites are transmitting initial Galileo signals. This paper focuses on the integration of Galileo and BeiDou in PPP, together with GPS and Glonass. Satellite orbits and clocks for all constellations are generated using a network adjustment with observation data collected by the IGS Multi-GNSS Experiment (MGEX, as well as from Fugro proprietary reference station network. The orbit processing strategy is described, and orbit accuracy for Galileo and BeiDou is assessed via orbit overlaps, for different arc lengths. Kinematic post-processed multi-GNSS positioning results are presented. The benefits of multiconstellation PPP are discussed in terms of enhanced availability and positioning accuracy.

  13. The role of evaporites in the formation of gems during metamorphism of carbonate platforms: a review

    Science.gov (United States)

    Giuliani, Gaston; Dubessy, Jean; Ohnenstetter, Daniel; Banks, David; Branquet, Yannick; Feneyrol, Julien; Fallick, Anthony E.; Martelat, Jean-Emmanuel

    2018-01-01

    The mineral and fluid inclusions trapped by gemstones during the metamorphism of carbonate platform successions are precious markers for the understanding of gem genesis. The nature and chemical composition of inclusions highlight the major contribution of evaporites through dissolution or fusion, depending on the temperature of formation from greenschist to granulite facies. The fluids are highly saline NaCl-brines circulating either in an open system in the greenschist facies (Colombian and Afghan emeralds) and with huge fluid-rock metasomatic interactions, or sulphurous fluids (ruby, garnet tsavorite, zoisite tanzanite and lapis-lazuli) or molten salts formed in a closed system with a low fluid mobility (ruby in marble) in the conditions of the amphibolite to granulite facies. These chloride-fluoride-sulphate ± carbonate-rich fluids scavenged the metals essential for gem formation. At high temperature, the anions SO4 2-, NO3 -, BO3 - and F- are powerful fluxes which lower the temperature of chloride- and fluoride-rich ionic liquids. They provided transport over a very short distance of aluminium and/or silica and transition metals which are necessary for gem growth. In summary, the genetic models proposed for these high-value and ornamental gems underline the importance of the metamorphism of evaporites formed on continental carbonate shelves and emphasise the chemical power accompanying metamorphism at moderate to high temperatures of evaporite-rich and organic matter-rich protoliths to form gem minerals.

  14. The application of a monolithic triphenylphosphine reagent for conducting Ramirez gem-dibromoolefination reactions in flow.

    Science.gov (United States)

    Roper, Kimberley A; Berry, Malcolm B; Ley, Steven V

    2013-01-01

    The application of a monolithic form of triphenylphosphine to the Ramirez gem-dibromoolefination reaction using flow chemistry techniques is reported. A variety of gem-dibromides were synthesised in high purity and excellent yield following only removal of solvent and no further off-line purification. It is also possible to perform the Appel reaction using the same monolith and the relationship between the mechanisms of the two reactions is discussed.

  15. Gains in the Education of Mathematics and Science GEMS: Teaching Robotics to High School Students

    Science.gov (United States)

    2013-01-01

    find amusing but that we find of less educational value, like having the robots say comical things. Those who have more teaching time would doubtless...Gains in the Education of Mathematics and Science GEMS: Teaching Robotics to High School Students by Edward M. Measure and Edward Creegan...TR-6220 January 2013 Gains in the Education of Mathematics and Science (GEMS): Teaching Robotics to High School Students Edward M

  16. Treatment of malignant biliary obstructions via the percutaneous approach; Interventionen bei malignen Gallenwegstenosen

    Energy Technology Data Exchange (ETDEWEB)

    Radeleff, B.A.; Lopez-Benitez, R.; Hallscheidt, P.; Grenacher, L.; Libicher, M.; Richter, G.M.; Kauffmann, G.W. [Radiologische Klinik der Ruprecht-Karls-Universitaet Heidelberg (Germany). Abteilung fuer Radiodiagnostik

    2005-11-01

    This paper gives an overview of experience and success of percutaneous transhepatic interventions in malignant biliary obstruction. Even after exhaustion of surgical and endoscopic therapy options, the percutaneously inserted stents provide effective palliation. The palliative treatment of malignant jaundice using a stent is an established procedure in clinical practice, particularly whenever the endoscopic, transpapillary approach is not possible due to high obstructions or previous surgery. The technical success rate is very high (about 95-100%), and the complication rate is about 10-30%. Since the patency rate of stents is higher than that of plastic endoprostheses, their primary use is justified despite higher costs, provided the patients are adequately selected. (orig.) [German] Vorgelegt wird eine Uebersicht ueber den gegenwaertigen Stellenwert radiologischer Interventionen bei malignen Gallenwegstenosen, die nur bei 10-20% der Patienten heilbar sind. Wenn ein endoskopisch transpapillaerer Zugang nicht moeglich ist, z. B. bei hohen Obstruktionen oder nach frueheren Eingriffen, ermoeglichen die perkutane transhepatische Punktion und Implantation von Metallendoprothesen eine gute Palliation. Die perkutane Gallengangdrainage und Stentplatzierung sind fuer den erfahrenen, interventionell taetigen Radiologen wenig kompliziert und mit einer Erfolgsrate von 95-100% dem endoskopischen Vorgehen deutlich ueberlegen. Morbiditaet und Mortalitaet der endoskopischen Verfahren waren in aelteren Arbeiten noch geringer als die der perkutanen Methoden. Aktuellen Studien zufolge sind beide Verfahren gleichwertig, wahrscheinlich aufgrund technischer Verbesserungen der perkutanen Interventionen. Die technische Erfolgsrate bei der Stentapplikation liegt ueber 95%. Mittels perkutaner transhepatischer biliaerer Drainageneinlage (PTCD) eingelegte Metallstents bleiben haeufiger und laenger offen als Plastikstents. Bei entsprechender Lebenserwartung des Patienten ist ihr Einsatz daher

  17. BoNus: Development and use of a radial TPC using cylindrical GEMs

    International Nuclear Information System (INIS)

    Fenker, H.; Baillie, N.; Bradshaw, P.; Bueltmann, S.; Burkert, V.; Christy, M.; Dodge, G.; Dutta, D.; Ent, R.; Evans, J.; Fersch, R.; Giovanetti, K.; Griffioen, K.; Ispiryan, M.; Jayalath, C.; Kalantarians, N.; Keppel, C.; Kuhn, S.; Niculescu, G.; Niculescu, I.

    2008-01-01

    A specialized system of target and detector was developed at Jefferson Lab to provide new access to information about neutron structure from electron-neutron interactions. It allows identification and measurement of spectator protons produced in e - d→e - p s X scattering events. The detector is a radial time-projection chamber optimized for the acceptance of low-momentum protons. Gas gain is provided by three cascaded curved Gas Electron Multipliers (GEMs), the first application of GEMs in any configuration other than flat. This article provides details about the development and construction of the detector, its performance, and the analysis of the data from the successful running of its first physics experiment

  18. First measurements with new high-resolution gadolinium-GEM neutron detectors

    CERN Document Server

    Pfeiffer, Dorothea; Birch, Jens; Etxegarai, Maddi; Hall-Wilton, Richard; Höglund, Carina; Hultman, Lars; Llamas-Jansa, Isabel; Oliveri, Eraldo; Oksanen, Esko; Robinson, Linda; Ropelewski, Leszek; Schmidt, Susann; Streli, Christina; Thuiner, Patrik

    2016-05-17

    European Spallation Source instruments like the macromolecular diffractometer, NMX, require an excellent neutron detection efficiency, high-rate capabilities, time resolution, and an unprecedented spatial resolution in the order of a few hundred micrometers over a wide angular range of the incoming neutrons. For these instruments solid converters in combination with Micro Pattern Gaseous Detectors (MPGDs) are a promising option. A GEM detector with gadolinium converter was tested on a cold neutron beam at the IFE research reactor in Norway. The {\\mu}TPC analysis, proven to improve the spatial resolution in the case of $^{10}$B converters, is extended to gadolinium based detectors. For the first time, a Gd-GEM was successfully operated to detect neutrons with an estimated efficiency of 10% at a wavelength of 2 {\\AA} and a position resolution better than 350 {\\mu}m.

  19. Hard assets : The return of rare diamonds and gems

    NARCIS (Netherlands)

    Renneboog, Luc; Spaenjers, Christophe; Grynberg, Roman; Mbayi, Letsema

    This note examines the investment performance of diamonds and other gems (sapphires, rubies, and emeralds) over the period 1999–2010, using a novel data set of auction transactions. Over our time frame, the annualized real USD returns for white and colored diamonds equaled 6.4% and 2.9%,

  20. Hard assets : The return on rare diamonds and gems

    NARCIS (Netherlands)

    Renneboog, L.D.R.; Spaenjers, C.

    2012-01-01

    This note examines the investment performance of diamonds and other gems (sapphires, rubies, and emeralds) over the period 1999–2010, using a novel data set of auction transactions. Over our time frame, the annualized real USD returns for white and colored diamonds equaled 6.4% and 2.9%,

  1. Hard Assets : The Returns on Rare Diamonds and Gems

    NARCIS (Netherlands)

    Renneboog, L.D.R.; Spaenjers, C.

    2011-01-01

    This paper examines the investment performance of diamonds and other gems (sapphires, rubies, and emeralds) over the period 1999-2010, using a novel data set of auction transactions. Between 1999 and 2010, the annualized real USD returns for white and colored diamonds equaled 6.4% and 2.9%,

  2. Laterale 10-fach-Biopsie der Prostata liefert bei Karzinomverdacht überlegene Detektionsraten

    Directory of Open Access Journals (Sweden)

    von Knobloch R

    2012-01-01

    Full Text Available Einleitung:Die Sextantenbiopsie der Prostata ist für eine verlässliche Karzinomdiagnostik nicht ausreichend. Vielerorts werden bereits bei der Erstbiopsie 12 Stanzen entnommen. In einer großen Serie von 10-fach-Biopsien unter bilateraler lokaler Leitungsanästhesie, wie bereits 2002 publiziert [1], überprüften wir die Qualität unserer Technik als Standard für die Erstbiopsie. Methode:Zwischen April 2005 und Dezember 2007 führten wir bei 736 Männern (Durchschnittsalter 67,5 ± 8,39 Jahre die Erstbiopsie der Prostata durch. Indikation für die Biopsie war entweder ein erhöhter PSA-Wert oder ein auffälliger Tastbefund. Bei allen Männern erfolgte die Biopsie der Prostata unter bilateraler lokaler Leitungsanästhesie. Es wurden nur Proben aus der peripheren Zone der Prostata unter transrektaler Ultraschallkontrolle entnommen. Ergebnisse:Durch die Biopsie wurde in 372 von 736 Fällen (50,5 % ein Karzinom identifiziert. Die Karzinomdetektionsrate war proportional zum PSA-Wert und indirekt proportional zum Organvolumen. Es zeigte sich eine eindeutige Korrelation zwischen der Anzahl positiver Stanzen bei der Biopsie mit dem pathologischen Stadium des Prostatektomiepräparates. 12 Männer (1,6 % mussten wegen akuter Prostatitis und 5 (0,7 % wegen rektaler Blutung wieder ins Krankenhaus eingewiesen werden. Von den 182 Patienten des Untersuchers R. v. K. wurde der durchschnittliche Schmerz der Biopsie mit 1,69 von maximal 10 angegeben. Die Detektions- und Komplikationsraten dieser Biopsietechnik unterschieden sich nicht nach Durchführung von Assistenz- oder Fachärzten. Schlussfolgerung: Die präsentierte Biopsietechnik liefert mit nur 10 Stanzen eine überlegene Detektionsrate und eine geringe Rate an Komplikationen. Sie sollte als Basis für die Definition eines Standards für die Erstbiopsie der Prostata bei Karzinomverdacht dienen.

  3. Kyphoplastie als palliative Therapieoption bei pathologischen Frakturen der Brust- und Lendenwirbelsäule

    Directory of Open Access Journals (Sweden)

    Hartwig E

    2004-01-01

    Full Text Available Bedingt durch Fortschritte in der Behandlung von Tumoren hat sich die Lebenserwartung von Krebspatienten deutlich verbessert. Jedoch steigt hiermit auch die Inzidenz von Knochenmetastasen. Mit wenigen Ausnahmen, die primären Knochentumoren betreffend, ist die Art der Behandlung dieser Läsionen in der Regel palliativ. Durch operatives Intervenieren muß bei diesen Patienten ein maximaler palliativer Effekt bei minimaler Morbidität und Mortalität erzielt werden. Die vorwiegenden Ziele sind Schmerzreduktion unter Erhalt der Stabilität und Funktion. Durch die Kyphoplastie wurden Zementierungsverfahren an der Wirbelsäule auch für pathologische Frakturen auf dem Boden metastatischer Manifestationen elegibel. In einer telefonischen Evaluation von 10 Patienten konnte die Wertigkeit des Verfahrens in der palliativen Situation bei Patienten mit Wirbelsäulenmetastasen gezeigt werden.

  4. Developments and the preliminary tests of Resistive GEMs manufactured by a screen printing technology

    CERN Document Server

    Agócs, G; Oliveira, R; Martinego, P; Peskov, Vladimir; Pietropaolo, P; Picchi, P

    2008-01-01

    We report promising initial results obtained with new resistive-electrode GEM (RETGEM) detectors manufactured, for the first time, using screen printing technology. These new detectors allow one to reach gas gains nearly as high as with ordinary GEM-like detectors with metallic electrodes; however, due to the high resistivity of its electrodes the RETGEM, in contrast to ordinary hole-type detectors, has the advantage of being fully spark protected. We discovered that RETGEMs can operate stably and at high gains in noble gases and in other badly quenched gases, such as mixtures of noble gases with air and in pure air; therefore, a wide range of practical applications, including dosimetry and detection of dangerous gases, is foreseeable. To promote a better understanding of RETGEM technology some comparative studies were completed with metallic-electrode thick GEMs. A primary benefit of these new RETGEMs is that the screen printing technology is easily accessible to many research laboratories. This accessibilit...

  5. The application of a monolithic triphenylphosphine reagent for conducting Ramirez gem-dibromoolefination reactions in flow

    Directory of Open Access Journals (Sweden)

    Kimberley A. Roper

    2013-09-01

    Full Text Available The application of a monolithic form of triphenylphosphine to the Ramirez gem-dibromoolefination reaction using flow chemistry techniques is reported. A variety of gem-dibromides were synthesised in high purity and excellent yield following only removal of solvent and no further off-line purification. It is also possible to perform the Appel reaction using the same monolith and the relationship between the mechanisms of the two reactions is discussed.

  6. Development of the DAQ System of Triple-GEM Detectors for the CMS Muon Spectrometer Upgrade at LHC

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00387583

    The Gas Electron Multiplier (GEM) upgrade project aims at improving the performance of the muon spectrometer of the Compact Muon Solenoid (CMS) experiment which will suffer from the increase in luminosity of the Large Hadron Collider (LHC). After a long technical stop in 2019-2020, the LHC will restart and run at a luminosity of 2 × 1034 cm−2 s−1, twice its nominal value. This will in turn increase the rate of particles to which detectors in CMS will be exposed and affect their performance. The muon spectrometer in particular will suffer from a degraded detection efficiency due to the lack of redundancy in its most forward region. To solve this issue, the GEM collaboration proposes to instrument the first muon station with Triple-GEM detectors, a technology which has proven to be resistant to high fluxes of particles. Within the GEM collaboration, the Data Acquisition (DAQ) subgroup is in charge of the development of the electronics and software of the DAQ system of the detectors. This thesis presents th...

  7. GEM detector performance with innovative micro-TPC readout in high magnetic field

    Directory of Open Access Journals (Sweden)

    Garzia I.

    2018-01-01

    Full Text Available Gas detector development is one of the pillars of the research in fundamental physics. Since several years, a new concept of detectors, called Micro Pattern Gas Detector (MPGD, allowed to overcome several problems related to other types of commonly used detectors, like drift chamber and micro strips detectors, reducing the rate of discharges and providing better radiation tolerance. Among the most used MPGDs are the Gas Electron Multipliers (GEMs. Invented by Sauli in 1997, nowadays GEMs have become an important reality for particle detectors in high energy physics. Commonly deployed as fast timing detectors and triggers, their fast response, high rate capability and high radiation hardness make them also suitable as tracking detectors. The readout scheme is one of the most important features in tracking technology. Analog readout based on the calculation of the center of gravity technique allows to overcome the limit imposed by digital pads, whose spatial resolution is limited by the pitch dimensions. However, the presence of high external magnetic fields can distort the electronic cloud and affect the performance. The development of the micro-TPC reconstruction method brings GEM detectors into a new prospective, improving significantly the spatial resolutionin presence of high magnetic fields. This innovative technique allows to reconstruct the 3-dimensional particle position, as Time Projection Chamber, but within a drift gap of a few millimeters. In these report, the charge centroid and micro-TPC methods are described in details. We discuss the results of several test beams performed with planar chambers in magnetic field. These results are one of the first developments of micro-TPC technique for GEM detectors, which allows to reach unprecedented performance in a high magnetic field of 1 T.

  8. GEM detector performance with innovative micro-TPC readout in high magnetic field

    Science.gov (United States)

    Garzia, I.; Alexeev, M.; Amoroso, A.; Baldini Ferroli, R.; Bertani, M.; Bettoni, D.; Bianchi, F.; Calcaterra, A.; Canale, N.; Capodiferro, M.; Cassariti, V.; Cerioni, S.; Chai, J. Y.; Chiozzi, S.; Cibinetto, G.; Cossio, F.; Cotta Ramusino, A.; De Mori, F.; Destefanis, M.; Dong, J.; Evangelisti, F.; Evangelisti, F.; Farinelli, R.; Fava, L.; Felici, G.; Fioravanti, E.; Gatta, M.; Greco, M.; Lavezzi, L.; Leng, C. Y.; Li, H.; Maggiora, M.; Malaguti, R.; Marcello, S.; Melchiorri, M.; Mezzadri, G.; Mignone, M.; Morello, G.; Pacetti, S.; Patteri, P.; Pellegrino, J.; Pelosi, A.; Rivetti, A.; Rolo, M. D.; Savrié, M.; Scodeggio, M.; Soldani, E.; Sosio, S.; Spataro, S.; Tskhadadze, E.; Verma, S.; Wheadon, R.; Yan, L.

    2018-01-01

    Gas detector development is one of the pillars of the research in fundamental physics. Since several years, a new concept of detectors, called Micro Pattern Gas Detector (MPGD), allowed to overcome several problems related to other types of commonly used detectors, like drift chamber and micro strips detectors, reducing the rate of discharges and providing better radiation tolerance. Among the most used MPGDs are the Gas Electron Multipliers (GEMs). Invented by Sauli in 1997, nowadays GEMs have become an important reality for particle detectors in high energy physics. Commonly deployed as fast timing detectors and triggers, their fast response, high rate capability and high radiation hardness make them also suitable as tracking detectors. The readout scheme is one of the most important features in tracking technology. Analog readout based on the calculation of the center of gravity technique allows to overcome the limit imposed by digital pads, whose spatial resolution is limited by the pitch dimensions. However, the presence of high external magnetic fields can distort the electronic cloud and affect the performance. The development of the micro-TPC reconstruction method brings GEM detectors into a new prospective, improving significantly the spatial resolutionin presence of high magnetic fields. This innovative technique allows to reconstruct the 3-dimensional particle position, as Time Projection Chamber, but within a drift gap of a few millimeters. In these report, the charge centroid and micro-TPC methods are described in details. We discuss the results of several test beams performed with planar chambers in magnetic field. These results are one of the first developments of micro-TPC technique for GEM detectors, which allows to reach unprecedented performance in a high magnetic field of 1 T.

  9. Performance of the full size nGEM detector for the SPIDER experiment

    Energy Technology Data Exchange (ETDEWEB)

    Muraro, A., E-mail: muraro@ifp.cnr.it [Istituto di Fisica del Plasma “P. Caldirola” – CNR, Milan (Italy); Dipartimento di Fisica “G. Occhialini”, University of Milano-Bicocca (Italy); Croci, G. [Istituto di Fisica del Plasma “P. Caldirola” – CNR, Milan (Italy); Dipartimento di Fisica “G. Occhialini”, University of Milano-Bicocca (Italy); Sez. INFN Milano-Bicocca, Milano (Italy); Albani, G. [Dipartimento di Fisica “G. Occhialini”, University of Milano-Bicocca (Italy); Claps, G. [Laboratori Nazionali di Frascati – INFN, Frascati (Italy); Cavenago, M. [Laboratori Nazionali di Legnaro – INFN, Legnaro (Italy); Cazzaniga, C. [Dipartimento di Fisica “G. Occhialini”, University of Milano-Bicocca (Italy); Dalla Palma, M. [Consorzio RFX, Padova (Italy); Grosso, G. [Istituto di Fisica del Plasma “P. Caldirola” – CNR, Milan (Italy); Murtas, F. [Laboratori Nazionali di Frascati – INFN, Frascati (Italy); Pasqualotto, R. [Consorzio RFX, Padova (Italy); Perelli Cippo, E. [Istituto di Fisica del Plasma “P. Caldirola” – CNR, Milan (Italy); Rebai, M. [Dipartimento di Fisica “G. Occhialini”, University of Milano-Bicocca (Italy); Tardocchi, M.; Tollin, M. [Istituto di Fisica del Plasma “P. Caldirola” – CNR, Milan (Italy); Gorini, G. [Dipartimento di Fisica “G. Occhialini”, University of Milano-Bicocca (Italy); Sez. INFN Milano-Bicocca, Milano (Italy)

    2016-03-21

    The ITER neutral beam test facility under construction in Padova will host two experimental devices: SPIDER, a 100 kV negative H/D RF beam source, and MITICA, a full scale, 1 MeV deuterium beam injector. SPIDER will start operations in 2016 while MITICA is expected to start during 2019. Both devices feature a beam dump used to stop the produced deuteron beam. Detection of fusion neutrons produced between beam-deuterons and dump-implanted deuterons will be used as a means to resolve the horizontal beam intensity profile. The neutron detection system will be placed right behind the beam dump, as close to the neutron emitting surface as possible thus providing the map of the neutron emission on the beam dump surface. The system uses nGEM neutron detectors. These are Gas Electron Multiplier detectors equipped with a cathode that also serves as neutron–proton converter foil. The cathode is designed to ensure that most of the detected neutrons at a point of the nGEM surface are emitted from the corresponding beamlet footprint (with dimensions of about 40×22 mm{sup 2}) on the dump front surface. The size of the nGEM detector for SPIDER is 352 mm×200 mm. Several smaller size prototypes have been successfully made in the last years and the experience gained on these detectors has led to the production of the full size detector for SPIDER during 2014. This nGEM has a read-out board made of 256 pads (arranged in a 16×16 matrix) each with a dimension of 22 mm×13 mm. This paper describes the production of this detector and its tests (in terms of beam profile reconstruction capability, uniformity over the active area, gamma rejection capability and time stability) performed on the ROTAX beam-line at the ISIS spallation source (Didcot-UK).

  10. Performance of the full size nGEM detector for the SPIDER experiment

    International Nuclear Information System (INIS)

    Muraro, A.; Croci, G.; Albani, G.; Claps, G.; Cavenago, M.; Cazzaniga, C.; Dalla Palma, M.; Grosso, G.; Murtas, F.; Pasqualotto, R.; Perelli Cippo, E.; Rebai, M.; Tardocchi, M.; Tollin, M.; Gorini, G.

    2016-01-01

    The ITER neutral beam test facility under construction in Padova will host two experimental devices: SPIDER, a 100 kV negative H/D RF beam source, and MITICA, a full scale, 1 MeV deuterium beam injector. SPIDER will start operations in 2016 while MITICA is expected to start during 2019. Both devices feature a beam dump used to stop the produced deuteron beam. Detection of fusion neutrons produced between beam-deuterons and dump-implanted deuterons will be used as a means to resolve the horizontal beam intensity profile. The neutron detection system will be placed right behind the beam dump, as close to the neutron emitting surface as possible thus providing the map of the neutron emission on the beam dump surface. The system uses nGEM neutron detectors. These are Gas Electron Multiplier detectors equipped with a cathode that also serves as neutron–proton converter foil. The cathode is designed to ensure that most of the detected neutrons at a point of the nGEM surface are emitted from the corresponding beamlet footprint (with dimensions of about 40×22 mm"2) on the dump front surface. The size of the nGEM detector for SPIDER is 352 mm×200 mm. Several smaller size prototypes have been successfully made in the last years and the experience gained on these detectors has led to the production of the full size detector for SPIDER during 2014. This nGEM has a read-out board made of 256 pads (arranged in a 16×16 matrix) each with a dimension of 22 mm×13 mm. This paper describes the production of this detector and its tests (in terms of beam profile reconstruction capability, uniformity over the active area, gamma rejection capability and time stability) performed on the ROTAX beam-line at the ISIS spallation source (Didcot-UK).

  11. The Gem Infrasound Logger and Custom-Built Instrumentation

    International Nuclear Information System (INIS)

    Anderson, Jacob F.; Ronan, Timothy J.

    2017-01-01

    Here, we designed, built, and recorded data with a custom infrasound logger (referred to as the Gem) that is inexpensive, portable, and easy to use. We also describe its design process, qualities, and applications in this article. Field instrumentation is a key element of geophysical data collection, and the quantity and quality of data that can be recorded is determined largely by the characteristics of the instruments used. Geophysicists tend to rely on commercially available instruments, which suffice for many important types of fieldwork. However, commercial instrumentation can fall short in certain roles, which motivates the development of custom sensors and data loggers. Particularly, we found existing data loggers to be expensive and inconvenient for infrasound campaigns, and developed the Gem infrasound logger in response. In this article, we discuss development of this infrasound logger and the various uses found for it, including projects on volcanoes, high-altitude balloons, and rivers. Further, we demonstrate that when needed, scientists can feasibly design and build their own specialized instruments, and that doing so can enable them to record more and better data at a lower cost.

  12. Endokrinologische Behandlung der Geschlechtsdysphorie bei Menschen mit Geschlechtsinkongruenz

    Directory of Open Access Journals (Sweden)

    Flütsch N

    2015-01-01

    Full Text Available Es gibt Menschen, die die innere Gewissheit besitzen, dass ihre Geschlechtsidentität nicht zu ihrem biologischen Ursprungsgeschlecht passt. Durch die Entwicklungen in der Medizin in den letzten hundert Jahren ist es möglich geworden, die körperlichen Geschlechtsmerkmale an das innerlich erlebte Geschlecht anzupassen. Die Zahl der Hilfesuchenden in den ärztlichen Ambulanzen und Privatpraxen hat in den vergangenen Jahren deutlich zugenommen. Das Vorgehen bei der Diagnostik und Therapieeinleitung erlebt zurzeit eine deutliche Veränderung hin zu mehr Patientenzentriertheit und Individualisierung des Transitionsprozesses. Dabei bildet die geschlechtsangleichende Hormontherapie ein wesentliches Standbein in der körperlichen Angleichung an das Gegengeschlecht. Unter Beachtung von bestimmten Sicherheitsaspekten ist eine Hormontherapie mit Sexualhormonen sicher und einfach durchzuführen. Regelmäßige Verlaufskontrollen sowie der offene und affirmative Umgang mit den Betroffenen tragen zudem wesentlich zur Sicherheit in der Behandlung bei.

  13. Some Interesting Mathematical Gems -R-ES-ONANCE--Isep-te ...

    Indian Academy of Sciences (India)

    Same thing applies to results cho- sen here" I shall not refer to gems like Godel's incom- plete theorern or the ... ematics, theoretical computer science, probability and statistics. Based on an invited talk dedi- cated to Dr P L Bhatnagar,. Founder Professor of the Math- ematics Department (then known as Department of Ap-.

  14. Evaluation of a regional real-time precise positioning system based on GPS/BeiDou observations in Australia

    Science.gov (United States)

    Ding, Wenwu; Tan, Bingfeng; Chen, Yongchang; Teferle, Felix Norman; Yuan, Yunbin

    2018-02-01

    The performance of real-time (RT) precise positioning can be improved by utilizing observations from multiple Global Navigation Satellite Systems (GNSS) instead of one particular system. Since the end of 2012, BeiDou, independently established by China, began to provide operational services for users in the Asia-Pacific regions. In this study, a regional RT precise positioning system is developed to evaluate the performance of GPS/BeiDou observations in Australia in providing high precision positioning services for users. Fixing three hourly updated satellite orbits, RT correction messages are generated and broadcasted by processing RT observation/navigation data streams from the national network of GNSS Continuously Operating Reference Stations in Australia (AUSCORS) at the server side. At the user side, RT PPP is realized by processing RT data streams and the RT correction messages received. RT clock offsets, for which the accuracy reached 0.07 and 0.28 ns for GPS and BeiDou, respectively, can be determined. Based on these corrections, an accuracy of 12.2, 30.0 and 45.6 cm in the North, East and Up directions was achieved for the BeiDou-only solution after 30 min while the GPS-only solution reached 5.1, 15.3 and 15.5 cm for the same components at the same time. A further improvement of 43.7, 36.9 and 45.0 percent in the three directions, respectively, was achieved for the combined GPS/BeiDou solution. After the initialization process, the North, East and Up positioning accuracies were 5.2, 8.1 and 17.8 cm, respectively, for the BeiDou-only solution, while 1.5, 3.0, and 4.7 cm for the GPS-only solution. However, we only noticed a 20.9% improvement in the East direction was obtained for the GPS/BeiDou solution, while no improvements in the other directions were detected. It is expected that such improvements may become bigger with the increasing accuracy of the BeiDou-only solution.

  15. Shoulder injuries in overhead sports; Schultergelenkverletzungen bei Ueberkopfsportarten

    Energy Technology Data Exchange (ETDEWEB)

    Woertler, K. [Technische Universitaet Muenchen (Germany). Institut fuer Roentgendiagnostik

    2010-05-15

    Overhead sport places great demands on the shoulder joint. Shoulder pain in overhead athletes and throwers can in the majority of cases be attributed to lesions resulting from chronic overuse of tendons and capsuloligamentous structures or to sequels of microinstability and secondary impingement. Due to its great impact on therapeutic decisions, imaging in athletes with unclear shoulder pain is a challenge. In this connection, magnetic resonance (MR) arthrography represents the cross-sectional imaging modality of first choice, as it allows depiction and exclusion of pathologic alterations of all relevant joint structures with sufficient confidence. This article reviews the biomechanical and clinical aspects and MR arthrographic features of the most common shoulder pathologies in overhead athletes, including biceps tendinopathy, superior labral anterior-posterior (SLAP) lesions, rotator cuff lesions, as well as extrinsic and intrinsic impingement syndromes. (orig.) [German] Ueberkopfsportarten stellen grosse Anforderungen an das Schultergelenk. Schulterbeschwerden bei Ueberkopf- und Wurfsportlern koennen in der Mehrzahl der Faelle auf eine chronische Ueberlastung von Sehnen und Kapsel-Band-Strukturen oder auf die Folgen einer Mikroinstabilitaet und sekundaerer Impingementsyndrome zurueckgefuehrt werden. Wegen ihres grossen Einflusses auf die Therapieentscheidung stellt die Bildgebung bei Athleten mit unklaren Schulterbeschwerden eine Herausforderung dar. Die MR-Arthrographie ist in diesem Zusammenhang als Schnittbildverfahren der ersten Wahl anzusehen, da sie den Nachweis bzw. Ausschluss pathologischer Veraenderungen aller relevanten Gelenkstrukturen mit ausreichender Sicherheit ermoeglicht. Dieser Artikel gibt eine Uebersicht ueber biomechanische und klinische Aspekte sowie MR-arthrographische Befunde der haeufigsten Schultergelenkpathologien bei Ueberkopfsportlern, wie Bizepstendinopathie, Superior-labral-anterior-posterior- (SLAP-)Laesionen, Laesionen der

  16. First results with the general equilibrium model GEM-E3 Switzerland

    International Nuclear Information System (INIS)

    Bahn, O.; Frei, C.

    2000-01-01

    The GEM-E3 model has been implemented and applied for Switzerland. It has been in particular used to assess an ecological tax reform in Switzerland. Results of this analysis are presented here. (author)

  17. Atmospheric gaseous elemental mercury (GEM concentrations and mercury depositions at a high-altitude mountain peak in south China

    Directory of Open Access Journals (Sweden)

    X. W. Fu

    2010-03-01

    Full Text Available China is regarded as the largest contributor of mercury (Hg to the global atmospheric Hg budget. However, concentration levels and depositions of atmospheric Hg in China are poorly known. Continuous measurements of atmospheric gaseous elemental mercury (GEM were carried out from May 2008 to May 2009 at the summit of Mt. Leigong in south China. Simultaneously, deposition fluxes of THg and MeHg in precipitation, throughfall and litterfall were also studied. Atmospheric GEM concentrations averaged 2.80±1.51 ng m−3, which was highly elevated compared to global background values but much lower than semi-rural and industrial/urban areas in China. Sources identification indicates that both regional industrial emissions and long range transport of Hg from central, south and southwest China were corresponded to the elevated GEM level. Seasonal and diurnal variations of GEM were observed, which reflected variations in source intensity, deposition processes and meteorological factors. Precipitation and throughfall deposition fluxes of THg and MeHg in Mt. Leigong were comparable or lower compared to those reported in Europe and North America, whereas litterfall deposition fluxes of THg and MeHg were higher compared to Europe and North America. This highlights the importance of vegetation to Hg atmospheric cycling. In th remote forest ecosystem of China, deposition of GEM via uptake of foliage followed by litterfall was very important for the depletion of atmospheric Hg. Elevated GEM level in ambient air may accelerate the foliar uptake of Hg through air which may partly explain the elevated litterfall deposition fluxes of Hg observed in Mt. Leigong.

  18. Working memory in volunteers and schizophrenics using BOLD fMRI; Das Arbeitsgedaechtnis bei Gesunden und bei Schizophrenen: Untersuchungen mit BOLD-fMRT

    Energy Technology Data Exchange (ETDEWEB)

    Giesel, F.L. [Deutsches Krebsforschungszentrum (DKFZ) Heidelberg, Abteilung Radiologie (Germany); Deutsches Krebsforschungszentrum (DKFZ), Abteilung Radiologie, Heidelberg (Germany); Hohmann, N. [Deutsches Krebsforschungszentrum (DKFZ) Heidelberg, Abteilung Radiologie (Germany); Psychiatrische Universitaetsklinik Heidelberg, Sektion Gerontopsychiatrie (Germany); Seidl, U.; Kress, K.R.; Schoenknecht, P.; Schroeder, J. [Psychiatrische Universitaetsklinik Heidelberg, Sektion Gerontopsychiatrie (Germany); Kauczor, H.-U.; Essig, M. [Deutsches Krebsforschungszentrum (DKFZ) Heidelberg, Abteilung Radiologie (Germany)

    2005-02-01

    Functional magnetic resonance imaging uses the blood oxygen level-dependent effect (BOLD MRI) for noninvasive display of cerebral correlatives of cognitive function. The importance for the understanding of physiological and pathological processes is demonstrated by investigations of working memory in schizophrenics and healthy controls. Working memory is involved in processing rather than storage of information and therefore is linked to complex processes such as learning and problem solving. In schizophrenic psychosis, these functions are clearly restricted. Training effects in the working memory task follow an inverse U-shape function, suggesting that cerebral activation reaches a peak before economics of the brain find a more efficient method and activation decreases. (orig.) [German] Die funktionelle Magnetresonanztomographie (fMRT) nutzt den ''blood oxygen level dependent effect'' (BOLD-Effekt) zur nichtinvasiven Darstellung zerebraler Korrelate kognitiver Funktionen. Die Bedeutung dieses Verfahrens fuer das Verstaendnis physiologischer und pathologischer Prozesse wird anhand von Untersuchungen zum Arbeitsgedaechtnis bei Schizophrenen und gesunden Kontrollpersonen verdeutlicht. Das Arbeitsgedaechtnis dient weniger der Speicherung, sondern vielmehr der Verarbeitung von Informationen und ist deshalb in komplexe Prozesse wie Lernen und Problemloesen eingebunden. Im Rahmen schizophrener Psychosen kommt es zu einer deutlichen Einschraenkung dieser Funktionen. Erwartungsgemaess zeigen sich unter Durchfuehrung eines Arbeitsgedaechtnisparadigmas Unterschiede in der zerebralen Aktivitaet, die jedoch bei den Erkrankten unter Therapie prinzipiell reversibel sind. Von Interesse sind auch Trainingseffekte bei Gesunden, wobei eine verminderte Aktivierung nach Training auf eine ''Oekonomisierung'' schliessen laesst. (orig.)

  19. Tryptophanabhängige Synthese von indolhaltigen Pigmenten bei verschiedenen humanpathogenen Asco- und Basidiomyceten

    OpenAIRE

    Nies, Silke Marie

    2006-01-01

    Der Begriff "Pigment" beschreibt in erster Linie farbige Substanzen. Pigmente sind aber darüber hinaus für wichtige metabolische oder physiologische Prozesse verantwortlich. Im Reich der Pilze gibt es eine Vielzahl von Pigmenten. Zu ihnen zählen die Melanine, die Carotenoide, die Naphthoquinone, die Phenoxazine, die Flavonoide sowie indolhaltige Pigmente. Gewisse Indolderivate wurden von einer Arbeitsgruppe um Prof. Mayser 1998 erstmals bei der Hefe Malassezia furfur beschrieben, bei der ...

  20. Benchmarking the CEMDATA07 database to model chemical degradation of concrete using GEMS and PHREEQC

    International Nuclear Information System (INIS)

    Jacques, Diederik; Wang, Lian; Martens, Evelien; Mallants, Dirk

    2012-01-01

    Thermodynamic equilibrium modelling of degradation of cement and concrete systems by chemically detrimental reactions as carbonation, sulphate attack and decalcification or leaching processes requires a consistent thermodynamic database with the relevant aqueous species, cement minerals and hydrates. The recent and consistent database CEMDATA07 is used as the basis in the studies of the Belgian near-surface disposal concept being developed by ONDRAF/NIRAS. The database is consistent with the thermodynamic data in the Nagra/PSI-Thermodynamic Database. When used with the GEMS thermodynamic code, thermodynamic modelling can be performed at temperatures different from the standard temperature of 25 C. GEMS calculates thermodynamic equilibrium by minimizing the Gibbs free energy of the system. Alternatively, thermodynamic equilibrium can also be calculated by solving a nonlinear system of mass balance equations and mass action equations, as is done in PHREEQC. A PHREEQC-database for the cement systems at temperatures different from 25 C is derived from the thermodynamic parameters and models from GEMS. A number of benchmark simulations using PHREEQC and GEM-Selektor were done to verify the implementation of the CEMDATA07 database in PHREEQC-databases. Simulations address a series of reactions that are relevant to the assessment of long-term cement and concrete durability. Verification calculations were performed for different systems with increasing complexity: CaO-SiO 2 -CO 2 , CaO-Al 2 O 3 -SO 3 -CO 2 , and CaO-SiO 2 -Al 2 O 3 -Fe 2 O 3 -MgO-SO 3 -CO 2 . Three types of chemical degradation processes were simulated: (1) carbonation by adding CO 2 to the bulk composition, (2) sulphate attack by adding SO 3 to the bulk composition, and (3) decalcification/leaching by putting the cement solid phase sequentially in contact with pure water. An excellent agreement between the simulations with GEMS and PHREEQC was obtained

  1. GEM-E3: A computable general equilibrium model applied for Switzerland

    Energy Technology Data Exchange (ETDEWEB)

    Bahn, O. [Paul Scherrer Inst., CH-5232 Villigen PSI (Switzerland); Frei, C. [Ecole Polytechnique Federale de Lausanne (EPFL) and Paul Scherrer Inst. (Switzerland)

    2000-01-01

    The objectives of the European Research Project GEM-E3-ELITE, funded by the European Commission and coordinated by the Centre for European Economic Research (Germany), were to further develop the general equilibrium model GEM-E3 (Capros et al., 1995, 1997) and to conduct policy analysis through case studies. GEM-E3 is an applied general equilibrium model that analyses the macro-economy and its interaction with the energy system and the environment through the balancing of energy supply and demand, atmospheric emissions and pollution control, together with the fulfillment of overall equilibrium conditions. PSI's research objectives within GEM-E3-ELITE were to implement and apply GEM-E3 for Switzerland. The first objective required in particular the development of a Swiss database for each of GEM-E3 modules (economic module and environmental module). For the second objective, strategies to reduce CO{sub 2} emissions were evaluated for Switzerland. In order to develop the economic, PSI collaborated with the Laboratory of Applied Economics (LEA) of the University of Geneva and the Laboratory of Energy Systems (LASEN) of the Federal Institute of Technology in Lausanne (EPFL). The Swiss Federal Statistical Office (SFSO) and the Institute for Business Cycle Research (KOF) of the Swiss Federal Institute of Technology (ETH Zurich) contributed also data. The Swiss environmental database consists mainly of an Energy Balance Table and of an Emission Coefficients Table. Both were designed using national and international official statistics. The Emission Coefficients Table is furthermore based on know-how of the PSI GaBE Project. Using GEM-E3 Switzerland, two strategies to reduce the Swiss CO{sub 2} emissions were evaluated: a carbon tax ('tax only' strategy), and the combination of a carbon tax with the buying of CO{sub 2} emission permits ('permits and tax' strategy). In the first strategy, Switzerland would impose the necessary carbon tax to achieve

  2. Construction of the TH-GEM detector components for metrology of low energy ionizing radiation

    Energy Technology Data Exchange (ETDEWEB)

    Silva, N.F.; Castro, M.C.; Caldas, L.V.E., E-mail: nsilva@ipen.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil); Silva, T.F.; Luz, H. Natal da [Universidade de São Paulo (IF/USP), São Paulo, SP (Brazil). Instituto de Física

    2017-07-01

    The Gas Electron Multiplier (GEM) detector was originally proposed as a position sensitive detector to determine trajectories of particles prevenient from high energy collisions. In order to study the potential of TH-GEM type detectors in dosimetric applications for low energy X-rays, specifically for the mammography standard qualities, it was proposed to construct a prototype with characteristics suitable for such use. In this work the general, structural and material parameters applicable to the necessary conditions were defined, establishing the process of construction of the components of a prototype. (author)

  3. Construction of the TH-GEM detector components for metrology of low energy ionizing radiation

    International Nuclear Information System (INIS)

    Silva, N.F.; Castro, M.C.; Caldas, L.V.E.; Silva, T.F.; Luz, H. Natal da

    2017-01-01

    The Gas Electron Multiplier (GEM) detector was originally proposed as a position sensitive detector to determine trajectories of particles prevenient from high energy collisions. In order to study the potential of TH-GEM type detectors in dosimetric applications for low energy X-rays, specifically for the mammography standard qualities, it was proposed to construct a prototype with characteristics suitable for such use. In this work the general, structural and material parameters applicable to the necessary conditions were defined, establishing the process of construction of the components of a prototype. (author)

  4. Construction of the TH-GEM detector components for metrology of low energy ionizing radiation

    Science.gov (United States)

    Silva, N. F.; Silva, T. F.; Castro, M. C.; Natal da Luz, H.; Caldas, L. V. E.

    2018-03-01

    The Gas Electron Multiplier (GEM) detector was originally proposed as a position sensitive detector to determine trajectories of particles prevenient from high-energy collisions. In order to study the potential of TH-GEM type detectors in dosimetric applications for low energy X-rays, specifically for the mammography standard qualities, it was proposed to construct a prototype with characteristics suitable for such use. In this work the general, structural and material parameters applicable to the necessary conditions were defined, establishing the process of construction of the components of a prototype.

  5. Systematic measurements of the gain and the energy resolution of single and double mask GEM detectors

    International Nuclear Information System (INIS)

    Biswas, S.; Schmidt, D.J.; Abuhoza, A.; Frankenfeld, U.; Garabatos, C.; Hehner, J.; Kleipa, V.; Morhardt, T.; Schmidt, C.J.; Schmidt, H.R.; Wiechula, J.

    2016-01-01

    Systematic studies on the gain and the energy resolution have been carried out by varying the voltage across the GEM foils for both single mask and double mask triple GEM detector prototypes. Variation of the gain and the energy resolution has also been measured by varying either the drift voltage, transfer voltage and induction voltage keeping other voltages constant. The results of the systematic measurements have been presented.

  6. GEnomes Management Application (GEM.app): a new software tool for large-scale collaborative genome analysis.

    Science.gov (United States)

    Gonzalez, Michael A; Lebrigio, Rafael F Acosta; Van Booven, Derek; Ulloa, Rick H; Powell, Eric; Speziani, Fiorella; Tekin, Mustafa; Schüle, Rebecca; Züchner, Stephan

    2013-06-01

    Novel genes are now identified at a rapid pace for many Mendelian disorders, and increasingly, for genetically complex phenotypes. However, new challenges have also become evident: (1) effectively managing larger exome and/or genome datasets, especially for smaller labs; (2) direct hands-on analysis and contextual interpretation of variant data in large genomic datasets; and (3) many small and medium-sized clinical and research-based investigative teams around the world are generating data that, if combined and shared, will significantly increase the opportunities for the entire community to identify new genes. To address these challenges, we have developed GEnomes Management Application (GEM.app), a software tool to annotate, manage, visualize, and analyze large genomic datasets (https://genomics.med.miami.edu/). GEM.app currently contains ∼1,600 whole exomes from 50 different phenotypes studied by 40 principal investigators from 15 different countries. The focus of GEM.app is on user-friendly analysis for nonbioinformaticians to make next-generation sequencing data directly accessible. Yet, GEM.app provides powerful and flexible filter options, including single family filtering, across family/phenotype queries, nested filtering, and evaluation of segregation in families. In addition, the system is fast, obtaining results within 4 sec across ∼1,200 exomes. We believe that this system will further enhance identification of genetic causes of human disease. © 2013 Wiley Periodicals, Inc.

  7. Fast drift CRID with GEM

    CERN Document Server

    Vavra, J; McCulloch, M; Stiles, P; Sauli, Fabio

    1999-01-01

    The only available technique at the present time, to perform particle identification up to 40-50 GeV/c in a 4 pi solenoidal geometry using the Cherenkov ring imaging method is the use of gaseous detectors filled with either TMAE or TEA photocathodes, and a combination of the gaseous, and solid or liquid radiators. If one would consider building such a device, one may want to investigate alternative methods of building a single-electron detector. This paper investigates the feasibility of using the GEM together with a simple MWPC detector employing 33 mu m diameter carbon wires to obtain a second coordinate. The results are compared to the CRID single-electron detector.

  8. Potenzielle Arzneimittelwechsel-wirkungen und unerwünschte Arzneimittelwirkungen bei stationären dermatologischen Patienten.

    Science.gov (United States)

    Koch, Lukas; Kränke, Birger; Aberer, Werner

    2016-11-01

    Informationen zur Häufigkeit von Arzneimittelwechselwirkungen und unerwünschten Arzneimittelwirkungen zu präsentieren und Hilfestellung zu leisten, wie diese wichtigen Probleme in der pharmakologischen Behandlung stationärer dermatologischer Patienten minimiert werden können. Die Medikation von 1 099 stationären dermatologischen Patienten wurde retrospektiv mittels einer Internet-basierten Software für Medikamenteninteraktionen (Diagnosia ® Check) auf Arzneimittelwechselwirkungen und unerwünschte Arzneimittelwirkungen analysiert. Wir beschreiben eine Gesamthäufigkeit relevanter Arzneimittelwechselwirkungen von 51,7 % mit durchschnittlich 3,2 Interaktionen pro betroffenem stationären Patienten. Arzneimittelkombinationen, die gemieden werden sollten, wurden bei 5,7 % der Studienpopulation festgestellt. Der wichtigste Risikofaktor war die Gesamtzahl der verabreichten Medikamente. Die Arzneimittelgruppen, die bei der Mehrzahl der Wechselwirkungen beteiligt waren, waren Analgetika, Herz-Kreislauf-Medikamente und gerinnungshemmende Medikamente sowie Antidepressiva. Das Risiko unerwünschte Arzneimittelwirkungen auszubilden wurde bei 53,1 % der stationären Patienten als "hoch" eingestuft. Die fünf wichtigsten unerwünschten Nebenwirkungen in dieser Patientengruppe waren Blutungen, Obstipation, anticholinerge Effekte, Sedierung und orthostatische Effekte. Potenzielle Arzneimittelwechselwirkungen sowie unerwünschte Arzneimittelwirkungen sind bei stationären dermatologischen Patienten alarmierend häufig. Bei jedem zweiten Patienten besteht die Gefahr, derartige Wechselwirkungen oder unerwünschte Nebenwirkungen zu erleiden und jeder zwanzigste Patient erhält eine Arzneimittelkombination, die nicht verabreicht werden sollte. Erhöhte Wachsamkeit ist erforderlich, um die gefährdeten Patienten zu erkennen. © 2016 Deutsche Dermatologische Gesellschaft (DDG). Published by John Wiley & Sons Ltd.

  9. Spinal metastases of malignant gliomas; Spinale Metastasierung bei malignen Gliomen. Zwei Fallbeschreibungen

    Energy Technology Data Exchange (ETDEWEB)

    Materlik, B; Steidle-Katic, U; Feyerabend, T; Richter, E [Medizinische Univ. Luebeck (Germany). Klinik fuer Strahlentherapie und Nuklearmedizin; Wauschkuhn, B [Medizinische Univ. Luebeck (Germany). Klinik fuer Neurologie

    1998-09-01

    Purpose: Extracranial metastases of malignant gliomas are rare. We report 2 cases with spinal metastases in patients suffering from glioma. Patients and Method: Two patients (33 and 57 years old) developed spinal canal metastases of a glioblastoma multiforme and anaplastic astrocytoma Grade III respectively 25 and 9 months after surgical resection and radiotherapy. Both metastases were confirmed pathohistologically. Results: Intraspinal metastases were irradiated with a total dose of 12.6 Gy and 50 Gy. Treatment withdrawal was necessary in one patient due to reduced clinical condition. Regression of neurological symptoms was observed in the second patient. Conclusions: Spinal spread of malignant glioma should be considered during care and follow-up in glioma patients with spinal symptoms. (orig.) [Deutsch] Hintergrund: Maligne Gliome metastasieren aeusserst selten extrakraniell. Wir stellen zwei Faelle einer spinalen Filialisierung bei Gliompatienten vor. Patientengut und Methode: Zwei Patienten (33 und 57 Jahre alt) entwickelten 25 bzw. neun Monate nach Resektion und postoperativer Radiatio eines Glioblastoma multiforme und eines anaplastischen Astrozytoms WHO-Grad III histologisch gesicherte intraspinale Metastasen, welche durch Sensibilitaetsstoerungen der Beine symptomatisch wurden. Ergebnisse: Die intraspinalen Filiae wurden mit 12,6 Gy bzw. 50 Gy bestrahlt. Bei einem Patienten musste die Radiatio wegen zunehmender Verschlechterung des Allgemeinzustandes abgebrochen werden, bei dem zweiten Patienten besserte sich die neurologische Symptomatik. Schlussfolgerung: Bei der Betreuung von Gliompatienten sollte, insbesondere in der Nachsorge, an die Moeglichkeit der spinalen Metastasierung mit entsprechender Symptomatik gedacht werden. (orig.)

  10. Pulmonary manifestations in collagen vascular diseases; Pulmonale Manifestationen bei Kollagenosen

    Energy Technology Data Exchange (ETDEWEB)

    Vogel, M.N.A. [Thoraxklinik, Universitaetsklinikum Heidelberg, Abteilung fuer Diagnostische und Interventionelle Radiologie mit Nuklearmedizin, Heidelberg (Germany); Universitaetsklinikum Heidelberg, Translational Lung Research Center (TLRC), Heidelberg (Germany); Kreuter, M. [Thoraxklinik, Universitaetsklinikum Heidelberg, Zentrum fuer interstitielle und seltene Lungenerkrankungen, Pneumologie und Beatmungsmedizin, Heidelberg (Germany); Universitaetsklinikum Heidelberg, Translational Lung Research Center (TLRC), Heidelberg (Germany); Kauczor, H.U. [Radiologische Klinik, Universitaetsklinikum Heidelberg, Abteilung fuer Diagnostische und Interventionelle Radiologie, Heidelberg (Germany); Universitaetsklinikum Heidelberg, Translational Lung Research Center (TLRC), Heidelberg (Germany); Heussel, C.P. [Thoraxklinik, Universitaetsklinikum Heidelberg, Abteilung fuer Diagnostische und Interventionelle Radiologie mit Nuklearmedizin, Heidelberg (Germany); Radiologische Klinik, Universitaetsklinikum Heidelberg, Abteilung fuer Diagnostische und Interventionelle Radiologie, Heidelberg (Germany); Universitaetsklinikum Heidelberg, Translational Lung Research Center (TLRC), Heidelberg (Germany)

    2016-10-15

    Pulmonary complications are frequent in patients with collagen vascular diseases (CVD). Frequent causes are a direct manifestation of the underlying disease, side effects of specific medications and lung infections. The standard radiological procedure for the work-up of pulmonary pathologies in patients with CVD is multidetector computed tomography (MDCT) with thin-slice high-resolution reconstruction. The accuracy of thin-slice CT for the identification of particular disease patterns is very high. The pattern of usual interstitial pneumonia (UIP) representing the direct pulmonary manifestation of rheumatoid arthritis (RA) can be identified with a sensitivity of 45 % and a specificity of 96 %. Both direct pulmonary manifestations, drug-induced toxicity and certain infections can have a similar appearance in thin-slice MDCT in various forms of CVD. Knowledge of the patterns and causes contributes to the diagnostic certainty. At first diagnosis of a CVD and associated pulmonary symptoms thin-slice MDCT is recommended. Clinical, lung function and imaging follow-up examinations should be performed every 6-12 months depending on the results of the MDCT. In every case the individual CT morphological patterns of pulmonary involvement must be identified. The combination of information on the anamnesis, clinical and imaging results is a prerequisite for an appropriate disease management. (orig.) [German] Pulmonale Komplikationen sind bei Patienten mit Kollagenosen keine Seltenheit. Haeufig sind eine direkte Manifestation der Grunderkrankung, eine Nebenwirkung der medikamentoesen Therapie oder eine Lungeninfektion die Ursachen. Das radiologische Standardverfahren zur Klaerung pulmonaler Pathologien bei Patienten mit Kollagenosen ist die Multidetektorcomputertomographie mit duennschichtigen Rekonstruktionen (Duennschicht-MDCT). Die Treffsicherheit der Duennschicht-MDCT ist fuer die Identifikation eines Erkrankungsmusters sehr hoch. So kann beispielsweise das Muster einer

  11. Die Rolle von Osteoklasten bei der arthritischen Knochenerosion

    Directory of Open Access Journals (Sweden)

    Schett G

    2003-01-01

    Full Text Available Knöcherne Erosionen stellen eine wesentliche Ursache für die funktionelle Einschränkung von Patienten mit rheumatoider Arthritis dar. Bis vor kurzem war über den Pathomechanismus dieser Veränderungen nur wenig bekannt. Dieser Review faßt die letzten Erkenntnisse über die Ausbildung einer Knochenschädigung bei entzündlichen Gelenkerkrankungen zusammen und fokussiert insbesondere die Rolle von Osteoklasten. Es wird ein Überblickzu den Hinweisen für eine Präsenz von Osteoklasten im entzündlich veränderten Gelenk gegeben. Weiters werden die Faktoren diskutiert, die die Osteoklastogenese im Rahmen einer Gelenkentzündung aktivieren können. Hier wird im besonderen auf die Rolle von Receptor-Activator of Nuclear Factor Kappa B Ligand (RANKL eingegangen. Im weiteren werden die Auswirkungen einer Osteoklastenhemmung in den verschiedenen Arthritismodellen zusammengefaßt und Möglichkeiten einer therapeutischen Nutzung bei rheumatoider Arthritis diskutiert.

  12. Dijk- en oeverval aan den cal. Willem Annapolder (Gem. Kapelle)

    NARCIS (Netherlands)

    Verhagen, H.J.

    1936-01-01

    Foto's van de aanleg van de dijk- en oeverval aan den cal. Willem Annapolder (Gem. Kapelle) 3. Linkerhelft dijkval Willem Annapolder. 30 Dec. 1936 4. Rechtehelft dijkval Willem Annapolder. 30 Dec. 1936 5. Overzicht dijkval Willem Annaolder. 30 Dec. 1936 6. Kleikisting binnendijks aangebacht. 14/15

  13. Characterization of multilayer Thick-GEM geometries as 10B converters aiming thermal neutron detection

    Directory of Open Access Journals (Sweden)

    Natal da Luz H.

    2018-01-01

    Full Text Available Boron-based thermal neutron detectors have recently regained some attention from the instrumentation community as a strong alternative to helium-3 detectors. From the existing concepts exploiting boron layers in position sensitive detectors, the Cascade [1] is the one that takes full advantage of the 2D capabilities of gaseous detectors, with the position resolution not limited by the architecture of the detector. In this work, a proposal for the Cascade detector, based on Thick-GEMs is presented, together with some preliminary studies of the suitable pitch that optimizes the neutron conversion efficiency, while keeping the collection efficiency intact. The characterization of Thick-GEM prototypes produced in Brazil with hole pitch from 0.75 to 3 mm shows that these devices already present a stable performance at low gains, also resulting in fair energy resolution, when cascaded with a standard KaptonTM 50 µm GEM. Results of the first attempts of boron film depositions with Ion Beam Assisted Deposition and characterization by Ion Beam Analysis are also presented.

  14. Characterization of multilayer Thick-GEM geometries as 10B converters aiming thermal neutron detection

    Science.gov (United States)

    Natal da Luz, H.; Souza, F. A.; Moralles, M.; Carlin, N.; Oliveira, R. A. N.; Bregant, M.; Suaide, A. A. P.; Chubaci, J. F. D.; Matsuoka, M.; Silva, T. F.; Moro, M. V.; Rodrigues, C. L.; Munhoz, M. G.

    2018-02-01

    Boron-based thermal neutron detectors have recently regained some attention from the instrumentation community as a strong alternative to helium-3 detectors. From the existing concepts exploiting boron layers in position sensitive detectors, the Cascade [1] is the one that takes full advantage of the 2D capabilities of gaseous detectors, with the position resolution not limited by the architecture of the detector. In this work, a proposal for the Cascade detector, based on Thick-GEMs is presented, together with some preliminary studies of the suitable pitch that optimizes the neutron conversion efficiency, while keeping the collection efficiency intact. The characterization of Thick-GEM prototypes produced in Brazil with hole pitch from 0.75 to 3 mm shows that these devices already present a stable performance at low gains, also resulting in fair energy resolution, when cascaded with a standard KaptonTM 50 µm GEM. Results of the first attempts of boron film depositions with Ion Beam Assisted Deposition and characterization by Ion Beam Analysis are also presented.

  15. Strahlungsfeldbedingungen bei der Ionisationsdosimetrie

    Science.gov (United States)

    Krieger, Hanno

    Bei der Dosimetrie von Photonenstrahlungen mit luftgefüllten Ionisationskammern werden in diesem Kapitel zwei Grenzfälle unterschieden. Der eine Fall ist die Bedingung des so genannten Sekundärelektronengleichwichts im Kammervolumen. In diesem Fall bestimmen ausschließlich die Photonen im Messvolumen die dosimetrische Anzeige. Der zweite Grenzfall ist gegeben, wenn das Luftvolumen und die Kammer das Strahlungsfeld im Phantom so wenig stören, dass der Sekundärelektronenfluss unverändert bleibt. Diese Bedingungen nennt man BRAGG-GRAY-Bedingungen. Beide Grenzfälle sind in der Praxis nur näherungsweise zu verwirklichen. Abweichungen müssen durch entsprechende Korrekturen oder Kalibrierungen berücksichtigt werden.

  16. Ion space-charge effects in multi-GEM detectors: challenges and possible solutions for future applications

    CERN Document Server

    AUTHOR|(CDS)2079251; Streli, Christina

    Gaseous Electron Multiplier (GEM) detectors are well known both for stable operation under irradiation with high particle fluxes and high achievable effective gains. The aim of this thesis is two-fold: to investigate the limits of GEM detector operation due to space-charge effects, and to develop a means to reduce the magnitude of the observed effects and thus extend those limitations. The first part of the thesis presents a comprehensive study of the intrinsic limits of triple-GEM detectors under exposure to very high fluxes of soft X-rays or operation at very large effective gains. The behaviour of the effective gain, ion back-flow and the pulse-height spectra is explained in terms of the movement and accumulation of positive ions throughout the detector volume, resulting in distortions of the transfer and amplification fields. Numerical computations, and measurements on double-stage and single-stage detectors confirm the model describing the observed effects. Discussions on ways to extend the limits of gas...

  17. Quality control for the first large areas of triple-GEM chambers for the CMS endcaps

    Science.gov (United States)

    Abbaneo, D.; Abbas, M.; Abbrescia, M.; Abi Akl, M.; Aboamer, O.; Acosta, D.; Ahmad, A.; Ahmed, W.; Aleksandrov, A.; Altieri, P.; Asawatangtrakuldee, C.; Aspell, P.; Assran, Y.; Awan, I.; Bally, S.; Ban, Y.; Banerjee, S.; Barashko, V.; Barria, P.; Bencze, G.; Beni, N.; Benussi, L.; Bhopatkar, V.; Bianco, S.; Bos, J.; Bouhali, O.; Braghieri, A.; Braibant, S.; Buontempo, S.; Calabria, C.; Caponero, M.; Caputo, C.; Cassese, F.; Castaneda, A.; Cauwenbergh, S.; Cavallo, F. R.; Celik, A.; Choi, M.; Choi, S.; Christiansen, J.; Cimmino, A.; Colafranceschi, S.; Colaleo, A.; Conde Garcia, A.; Czellar, S.; Dabrowski, M. M.; De Lentdecker, G.; De Oliveira, R.; de Robertis, G.; Dildick, S.; Dorney, B.; Endroczi, G.; Errico, F.; Fenyvesi, A.; Ferry, S.; Furic, I.; Giacomelli, P.; Gilmore, J.; Golovtsov, V.; Guiducci, L.; Guilloux, F.; Gutierrez, A.; Hadjiiska, R. M.; Hauser, J.; Hoepfner, K.; Hohlmann, M.; Hoorani, H.; Iaydjiev, P.; Jeng, Y. G.; Kamon, T.; Karchin, P.; Korytov, A.; Krutelyov, S.; Kumar, A.; Kim, H.; Lee, J.; Lenzi, T.; Litov, L.; Loddo, F.; Madorsky, A.; Maerschalk, T.; Maggi, M.; Magnani, A.; Mal, P. K.; Mandal, K.; Marchioro, A.; Marinov, A.; Majumdar, N.; Merlin, J. A.; Mitselmakher, G.; Mohanty, A. K.; Mohapatra, A.; Molnar, J.; Muhammad, S.; Mukhopadhyay, S.; Naimuddin, M.; Nuzzo, S.; Oliveri, E.; Pant, L. M.; Paolucci, P.; Park, I.; Passeggio, G.; Pavlov, B.; Philipps, B.; Piccolo, D.; Postema, H.; Puig Baranac, A.; Radi, A.; Radogna, R.; Raffone, G.; Ranieri, A.; Rashevski, G.; Riccardi, C.; Rodozov, M.; Rodrigues, A.; Ropelewski, L.; RoyChowdhury, S.; Ryu, G.; Ryu, M. S.; Safonov, A.; Salva, S.; Saviano, G.; Sharma, A.; Sharma, A.; Sharma, R.; Shah, A. H.; Shopova, M.; Sturdy, J.; Sultanov, G.; Swain, S. K.; Szillasi, Z.; Talvitie, J.; Tatarinov, A.; Tuuva, T.; Tytgat, M.; Vai, I.; Van Stenis, M.; Venditti, R.; Verhagen, E.; Verwilligen, P.; Vitulo, P.; Volkov, S.; Vorobyev, A.; Wang, D.; Wang, M.; Yang, U.; Yang, Y.; Yonamine, R.; Zaganidis, N.; Zenoni, F.; Zhang, A.

    2018-02-01

    The CMS Collaboration plans to equip the very forward muon system with triple-GEM detectors that can withstand the environment of the High-Luminosity LHC. This project is at the final stages of R&D and moving to production. An unprecedented large area of several 100 m2 are to be instrumented with GEM detectors which will be produced in six different sites around the world. A common construction and quality control procedure is required to ensure the performance of each detector. The quality control steps will include optical inspection, cleaning and baking of all materials and parts used to build the detector, leakage current tests of the GEM foils, high voltage tests, gas leak tests of the chambers and monitoring pressure drop vs. time, gain calibration to know the optimal operation region of the detector, gain uniformity tests, and studying the efficiency, noise and tracking performance of the detectors in a cosmic stand using scintillators.

  18. Quality control for the first large areas of triple-GEM chambers for the CMS endcaps

    Directory of Open Access Journals (Sweden)

    Abbaneo D.

    2018-01-01

    Full Text Available The CMS Collaboration plans to equip the very forward muon system with triple-GEM detectors that can withstand the environment of the High-Luminosity LHC. This project is at the final stages of R&D and moving to production. An unprecedented large area of several 100 m2 are to be instrumented with GEM detectors which will be produced in six different sites around the world. A common construction and quality control procedure is required to ensure the performance of each detector. The quality control steps will include optical inspection, cleaning and baking of all materials and parts used to build the detector, leakage current tests of the GEM foils, high voltage tests, gas leak tests of the chambers and monitoring pressure drop vs. time, gain calibration to know the optimal operation region of the detector, gain uniformity tests, and studying the efficiency, noise and tracking performance of the detectors in a cosmic stand using scintillators.

  19. Quality control for the first large areas of triple-GEM chambers for the CMS endcaps

    CERN Document Server

    AUTHOR|(CDS)2068936; Abbas, M.; Abbrescia, M.; Abi Akl, M.; Aboamer, O.; Acosta, D.; Ahmad, A.; Ahmed, W.; Aleksandrov, A.; Altieri, P.; Asawatangtrakuldee, C.; Aspell, P.; Assran, Y.; Awan, I.; Bally, S.; Ban, Y.; Banerjee, S.; Barashko, V.; Barria, P.; Bencze, G.; Beni, N.; Benussi, L.; Bhopatkar, V.; Bianco, S.; Bos, J.; Bouhali, O.; Braghieri, A.; Braibant, S.; Buontempo, S.; Calabria, C.; Caponero, M.; Caputo, C.; Cassese, F.; Castaneda, A.; Cauwenbergh, S.; Cavallo, F.R.; Celik, A.; Choi, M.; Choi, S.; Christiansen, J.; Cimmino, A.; Colafranceschi, S.; Colaleo, A.; Conde Garcia, A.; Czellar, S.; Dabrowski, M.M.; De Lentdecker, G.; De Oliveira, R.; de Robertis, G.; Dildick, S.; Dorney, B.; Endroczi, G.; Errico, F.; Fenyvesi, A.; Ferry, S.; Furic, I.; Giacomelli, P.; Gilmore, J.; Golovtsov, V.; Guiducci, L.; Guilloux, F.; Gutierrez, A.; Hadjiiska, R.M.; Hauser, J.; Hoepfner, K.; Hohlmann, M.; Hoorani, H.; Iaydjiev, P.; Jeng, Y.G.; Kamon, T.; Karchin, P.; Korytov, A.; Krutelyov, S.; Kumar, A.; Kim, H.; Lee, J.; Lenzi, T.; Litov, L.; Loddo, F.; Madorsky, A.; Maerschalk, T.; Maggi, M.; Magnani, A.; Mal, P.K.; Mandal, K.; Marchioro, A.; Marinov, A.; Majumdar, N.; Merlin, J.A.; Mitselmakher, G.; Mohanty, A.K.; Mohapatra, A.; Molnar, J.; Muhammad, S.; Mukhopadhyay, S.; Naimuddin, M.; Nuzzo, S.; Oliveri, E.; Pant, L.M.; Paolucci, P.; Park, I.; Passeggio, G.; Pavlov, B.; Philipps, B.; Piccolo, D.; Postema, H.; Puig Baranac, A.; Radi, A.; Radogna, R.; Raffone, G.; Ranieri, A.; Rashevski, G.; Riccardi, C.; Rodozov, M.; Rodrigues, A.; Ropelewski, L.; RoyChowdhury, S.; Ryu, G.; Ryu, M.S.; Safonov, A.; Salva, S.; Saviano, G.; Sharma, A.; Sharma, A.; Sharma, R.; Shah, A.H.; Shopova, M.; Sturdy, J.; Sultanov, G.; Swain, S.K.; Szillasi, Z.; Talvitie, J.; Tatarinov, A.; Tuuva, T.; Vai, I.; Van Stenis, M.; Venditti, R.; Verhagen, E.; Verwilligen, P.; Vitulo, P.; Volkov, S.; Vorobyev, A.; Wang, D.; Wang, M.; Yang, U.; Yang, Y.; Yonamine, R.; Zaganidis, N.; Zenoni, F.; Zhang, A.

    2015-01-01

    The CMS Collaboration plans to equip the very forward muon system with triple-GEM detectors that can withstand the environment of the High-Luminosity LHC. This project is at the final stages of R&D and moving to production. An unprecedented large area of several 100 m2 are to be instrumented with GEM detectors which will be produced in six different sites around the world. A common construction and quality control procedure is required to ensure the performance of each detector. The quality control steps will include optical inspection, cleaning and baking of all materials and parts used to build the detector, leakage current tests of the GEM foils, high voltage tests, gas leak tests of the chambers and monitoring pressure drop vs. time, gain calibration to know the optimal operation region of the detector, gain uniformity tests, and studying the efficiency, noise and tracking performance of the detectors in a cosmic stand using scintillators.

  20. Neuere Untersuchungen zur Prädiktion von EEG-Signalen bei Epilepsie

    Directory of Open Access Journals (Sweden)

    C. Niederhöfer

    2007-06-01

    Full Text Available Seit einigen Jahren ist die Analyse von EEG-Signalen bei Epilepsie Gegenstand zahlreicher wissenschaftlicher Arbeiten; Zielvorstellung ist dabei die Entwicklung von Verfahren zur Erkennung eines möglichen Voranfallszustandes. Im Vordergrund steht beispielsweise die Approximation einer so genannten effektiven Korrelationsdimension, die Bestimmung der maximalen Lyapunov-Exponenten, Detektionsverfahren für Muster bei Zellularen Nichtlinearen Netzwerken, die Bestimmung der mittleren Phasenkohärenz und Verfahren zur nichtlinearen Prädiktion von EEG-Signalen. Trotz umfangreicher Bemühungen kann bis heute eine Erkennung von Anfallsvorboten mit einer Sensitivität und Spezifität, die eine automatisierte Anfallsvorhersage ermöglichen würde, noch nicht durchgeführt werden. In diesem Beitrag werden neue Ergebnisse zur Prädiktion von EEG-Signalen bei Epilepsie vorgestellt. Dabei werden Signale, welche mittels intrakranieller electrocorticographischer (ECoG und stereoelectroencephalographischer (SEEG Ableitungen registriert wurden, segmentweise analysiert. Unter der Annahme, dass sich Änderungen des Systems ,,Gehirn" als Änderungen im Prädiktor, d.h. in seinen Systemparametern widerspiegeln, könnte eine nähere Betrachtung der Prädiktoreigenschaften zu einer Erkennung von Anfallsvorboten führen.

  1. Test beam studies of Gas Electron Multiplier (GEM) detectors for the upgrade of CMS endcap muon system

    CERN Document Server

    Sharma, Ram Krishna

    2017-01-01

    The High Luminosity LHC (HL-LHC) will provide exceptional high instantaneous and integrated luminosity. The forward region $\\mid \\eta \\mid \\geq 1.5$ of the CMS detector will face extremely high particle rates in tens of $KHz/cm^{2}$ and hence it will affect the momentum resolution and longevity of the muon detectors. To overcome these issues the CMS collaboration has decided to install new large size rate capable Triple Gas Electron Multiplier (GEM) detectors in the forward region of CMS muon system. The first set of Triple GEM detectors will be installed in the GE1/1 region $(1.5 \\leq \\eta \\leq 2.2)$ of muon endcap during the LS2 of the LHC and the next one will be installed in the GE2/1 region $(1.6 \\leq \\eta \\leq 2.5)$, during the LS3. Towards this goal, full-size CMS Triple GEM prototype chambers have been fabricated and put under the test beam at the CERN SPS test beam facility. The GEM detectors were operated with two gas mixtures $Ar/CO_{2}$ (70/30) and $Ar/CO_{2}/CF_{4}$ (40/15/45). In 2014 and 2016, ...

  2. Anwendung der extrakorporalen Stoßwellentherapie bei kalzifizierender Periathropathia humeroscapularis, Fersensporn und Epicondylitis humeri - Erfahrungsbericht aus dem Wilhelminenspital

    Directory of Open Access Journals (Sweden)

    Feyertag J

    2004-01-01

    Full Text Available Die Stoßwellentherapie wird bei verschiedenen Indikationen, die unter konservativen Therapien schwer zu schwer zu behandeln sind, eingesetzt. Dazu zählen die kalzifizierenden Schultererkrankungen (Tendinitis calcarea, Epicondylitis humeri (EHR und die plantare Fasciitis mit/ohne plantarem Fersensporn (FSP. Berichtet werden die Ergebnisse von 147 Patienten (102 Frauen/45 Männer, mittleres Alter betrug 57,8 Jahre, die mittels einer einmaligen extrakorporalen Stoßwellentherapie (ESWT (Tend. calc. 82 %, FSP 11 % oder EHR 7 % mittels eines HMT-ReflecTron therapiert wurden. Verabreicht wurden im Mittel 1.800 Stoßwellen. Untersucht wurde die subjektive Verbesserung der Schmerzen anhand einer visuellen Analogskala vor und 6 Wochen nach der Therapie bei allen Patienten. Bei Patienten mit Tendinitis calcarea wurde auch eine Verbesserung der Funktion sowie Veränderungen der Kalzifizierungen untersucht. Bei allen Patienten konnte eine statistisch signifikante Verbesserung der Schmerzen sowie des Bewegungsumfanges beobachtet werden (p 0,0001. Röntgenaufnahmen ergaben eine partielle Verkleinerung der Kalkdepots bei ca. 80 % der Patienten. Aufgrund der geringen Zahl der Patienten fand sich für die EHR keine signifikante Verbesserung der Schmerzsymptomatik. Eine einmalige ESWT kann zu einer deutlichen Verbesserung der Schmerzsymptomatik und zu einer Verbesserung des Bewegungsumfanges führen. Bei 80 % der Patienten mit einer Tendinitis calcarea findet sich weiter eine partielle Verkleinerung der Kalkdepots 6 Wochen nach Therapie.

  3. Magnetic resonance tomography in eclampsia; Magetresonanztomographie bei Eklampsie

    Energy Technology Data Exchange (ETDEWEB)

    Uhlig, U. [St.-Vincentius-Krankenhaeuser, Karlsruhe (Germany). Radiologische Klinik

    1995-05-01

    Eclampsia is a rare but severe complication during the course of a pregnancy. The CT-findings at the brain are well known. Reports on MRT-findings are limited, however, especially in German literature. We describe the MRT picture of the cerebral changes caused by eclampsia and discuss the advantages of MRT in comparison with CT. The use of contrast agents with MRT shows breakdown of blood-brain barrier but does not provide any information of therapeutical consequences and should be avoided during pregnancy. An early and targeted use of MRT in any case of unclear or suspicious neurological symptoms during pregnancy is recommended. MRT supports differential diagnosis regarding non pregnancy-related cerebral disease and can be helpful for therapy planning in cases of preeclampsia. Additionally, MRT offers the possibility to control the effect of therapy with regard to brain damage. (orig.) [Deutsch] Die Eklampsie ist eine seltene aber erhebliche Komplikation im Verlauf einer Schwangerschaft. Die computertomographischen Veraenderungen im Gehirn sind bekannt. Mitteilungen von kernspintomographischen Befunden finden sich vor allem in der deutschen Literatur noch selten. Wir beschreiben das kernspintomographische Bild der zerebralen Veraenderungen bei Eklampsie und diskutieren die Vorteile der MRT im Vergleich zur CT. Die Gabe von Kontrastmittel bei der MRT weist zwar die Blut-Hirn-Schrankenstoerung nach, bringt aber keine therapeutisch relevanten Informationen. Sie sollte waehrend der Schwangerschaft vermieden werden. Ein frueher und gezielter Einsatz der MRT bei unklaren oder verdaechtigen neurologischen Symptomen waehrend der Schwangerschaft ist sinnvoll. Die MRT unterstuetzt die Differentialdiagnose in bezug auf nicht schwangerschaftsbezogene zerebrale Leiden und kann fuer die Therapie richtungweisend sein, wenn die Gestose noch nicht ausgepraegt ist. (orig.)

  4. PENGARUH CORPORATE GOVERNANCE TERHADAP TAX AVOIDANCE (Perusahaan Pertambangan yang terdaftar di BEI

    Directory of Open Access Journals (Sweden)

    Sri Mulyani

    2018-05-01

    Full Text Available he purpose of this research is to know the influence of institutional ownership, independent commissioner, audit committee and audit quality to tax avoidance at mining company listed on BEI year 2014-2016. The population of this study is mining companies listed on the BEI 2014-2016 as many as 46 companies. Sampling used in this research purposive sampling method. Data source is secondary data obtained from company website and BEI website (www.idx.co.id. This study uses multiple regression analysis to analyze data with the help of SPSS 21 edition program. The results of this study indicate that the variables of institutional ownership, audit committee and audit quality have significant influence on tax avoidance, while independent commissioner variable has no significant effect on tax avoidance. The results of this study are expected to be an additional consideration of the management in conducting tax avoidance is correct and efficient without violating applicable tax laws, and can provide additional information for users of financial statements in investment decision making.

  5. International Genetically Engineered Machine (iGEM) Competition

    CSIR Research Space (South Africa)

    Sparrow, RW

    2010-07-01

    Full Text Available . At this meeting it was requested that the CSIR act as the administrative co-ordinating arm of the team. Following from this meeting a brochure was produced advertising the iGEM competition inside Wits and for Honours student nominations to be team members.... The academic year in South Africa commences in February. By late February 2010 student nominations had been received from which the supervisors selected the team members. The first team meeting was held on 5th March 2010. After which the team...

  6. The GEM Theory of the Unification of Gravitation and Electro-Magnetism

    Science.gov (United States)

    Brandenburg, J. E.

    2012-01-01

    The GEM (Gravity Electro-Magnetism), theory is presented as an alloy of Sakharov and Kaluza-Klein approaches to field unification. GEM uses the concept of gravity fields as Poynting fields to postulate that the non-metric portion of the EM stress tensor becomes the metric tensor in strong fields leading to "self-censorship". Covariant formulation of the GEM theory is accomplished through definition of the spacetime metric tensor as a portion of the EM stress tensor normalized by its own trace: gab = 4(FcaFcb )/(FabFab), it is found that this results in a massless ground state vacuum and a Newtonian gravitation potential f=1/2 E2/B2 =GM/r , where E, B and F are part of the vacuum Zero Point Fluctuation (ZPF) and M and r are the mass and distance from the center of a gravitating body and G is the Newton gravitation constant. It is found that a Lorentz flat-space metric is recovered in the limit of a vacuum full spectrum ZPF. The vacuum ZPF energy and vacuum quantities G, h, c, gives birth to particles quantities mp, me, e,-e in a process triggered by the appearance of the Kaluza-Klein fifth dimension, where also the EM and gravity forces split from each other in a process correlated to the splitting apart of protons and electrons. The separate appearance of the proton and electron occurs as the splitting of a light-like spacetime interval of zero-length into a finite space-like portion containing three subdimensions identified with the quarks and a time-like portion identified with the electron. The separation of mass with charge for the electron and proton pair comes about from a U(1) symmetry with a rotation in imaginary angle. A logarithmic variation of charge with mass for the proton-electron pair results and leads to the formula ln(ro/rp) = s, where s = (mp/me)1/2 , where mp and me are the electron and proton masses respectively and where ro =e2/moc2 , and where mo = (mpme)1/2 and where rp is the Planck length . This leads to the formula G=e2/mo2aexp(-2s)=6

  7. GEM, Fuel Cycle Cost and Economics for Thermal Reactor, Present Worth Analysis

    International Nuclear Information System (INIS)

    Hughes, J.A.; Hang, D.F.

    1974-01-01

    1- Description of problem or function: GEM is used to predict fuel cycle costs for any type nuclear system (i.e., BWR, HTGR, PWR, LMFBR, GCFR,... ). The current version is limited to thermal reactors. GEM is designed for production use by large utilities which have several reactor types on their system. GEM has been written so as to accommodate all major fuel management activities undertaken by a utility - (1) fuel bid analysis, (2) evaluation of actual day to day operation, and (3) system simulation and optimization studies. 2 - Method of solution: Costs are calculated using present-worth techniques and continuous compounding. The equations are based on an investor-owned utility capitalization structure which easily covers the range of industrial, private, and public (government) owned utilities. Three distinct types of analysis (cash flow, allocated costs, yearly cash flow) are performed, each yielding identical results. Using these as a basis many other analyses are undertaken. 3 - Restrictions on the complexity of the problem: Dimensions of all arrays are carried as variables throughout the analysis. The maximum size of each array is set by the user in program MAIN. Current values are set so that maxima are: 50 batches per case study, 20 year batch life, 30 year case study, 120 batch burn time-steps, 20 individual payments (sales) associated with each cost component

  8. Einflussfaktoren auf den persönlichen Stress bei Studienanfängern in der Humanmedizin

    OpenAIRE

    Schulze, Johannes; Duderstadt, Monika; Hodjat, Beheshta; Wu, Yue-Ying

    2013-01-01

    Die derzeitige Regelung der Zulassung zum Medizinstudium berücksichtigt die Abiturnote und Wartezeiten; universitäre Parameter können diese Kriterien modifizieren. Hierzu zählen z.B. die Leistungskurswahl, wie es an der Goethe-Universität Frankfurt gehandhabt wird. Im Rahmen der Untersuchung zu Stress und Resilienz bei Medizinstudenten haben wir bei den Studenten des 1. vorklinischen Semesters soziodemographische Daten erhoben, die einen Kohortenvergleich erlauben. Die chronische Stressbelast...

  9. Aging measurements on triple-GEM detectors operated with $CF_{4}$-based gas mixtures

    CERN Document Server

    Alfonsi, M; De Simone, P; Murtas, F; Poli Lener, M P; Bonivento, W; Cardini, A; Raspino, D; Saitta, B; Pinci, D; Baccaro, S; 10.1016/j.nuclphysbps.2005.03.054

    2006-01-01

    We present the results of a global irradiation test of full size triple-GEM detectors operated with CF/sub 4/-based gas mixtures. This study has been performed in the framework of an R&D activity on detectors for the innermost region of the first muon station of the LHCb experiment. The prototypes have been irradiated at the Calliope facility of the ENEA-Casaccia with a high intensity 1.25 MeV detectors performances have been measured with X-rays and with a 3 Ge V pion beam at CERN. A SEM analysis on several samples of the detectors has been performed to complete the understanding of the physical processes occurring in a GEM detector during a strong irradiation.

  10. PC-BEIS: a personal computer version of the biogenic emissions inventory system

    International Nuclear Information System (INIS)

    Pierce, T.E.; Waldruff, P.S.

    1991-01-01

    The US Environmental Protection Agency's Biogenic Emissions Inventory System (BEIS) has been adapted for use on IBM-compatible personal computers (PCs). PC-BEIS estimates hourly emissions of isoprene, α-pinene, other monoterpenes, and unidentified hydrocarbons for any county in the contiguous United States. To run the program, users must provide hourly data on ambient temperature, relative humidity, wind speed, cloud cover, and a code that identifies the particular county. This paper provides an overview of the method used to calculate biogenic emissions, shows an example application, and gives information on how to obtain a copy of the program

  11. Bewältigungsstrategien der Oberwalliser Primarlehrpersonen und Massnahmen der Gesundheitsförderung an Oberwalliser Primarschulen bei Stress und Burnout

    OpenAIRE

    Imhof, Barbara; Mattig, Astrid

    2009-01-01

    Die vorliegende Studie befasst sich mit der Gesundheitsförderung bei Stress und Burnout an den Oberwalliser Primarschulen und der Bewältigungsstrategien der Oberwalliser Primarlehrpersonen bei Stress und Burnout. Der theoretische Teil befasst sich mit Stress und Burnout und der Bewältigung von Stress und Burnout. Verschiedene Aspekte des Lehrerberufs werden näher angeschaut und es werden mögliche Massnahmen der Gesundheitsförderung bei Stress und Burnout aufgeführt. Die Untersuchung zeigt, da...

  12. Botulinumtoxin-A in der Behandlung neurogener Blasenfunktionsstörungen bei Kindern: Funktionelle und histomorphologische Langzeitergebnisse

    Directory of Open Access Journals (Sweden)

    Schulte-Baukloh H

    2004-01-01

    Full Text Available Die etablierte Therapie der neurogenen Detrusorhyperaktivität bei Kindern besteht in der Gabe von Anticholinergika und begleitendem intermittierendem Einmalkatheterismus. Eine hohe Nebenwirkungsrate der Anticholinergika oder eine nicht ausreichende Dämpfung der Detrusoraktivität limitiert jedoch die Anwendung und zwingt nicht selten zu einem operativen Vorgehen. Wir untersuchten deshalb die Wirksamkeit von Botulinumtoxin-A (BTX-A auf die neurogene Detrusorhyperaktivität bei Kindern mit neurogener Blasenfunktionsstörung. Hierzu wurden 24 Kinder (11 Mädchen, 13 Jungen; 2,5–20 (Ø 11,9 Jahre mit maximalem Detrusordruck 40 cm H2O trotz anticholinerger Medikation in die Studie eingeschlossen. Nach urodynamischer Evaluierung wurden gewichtsadaptiert 85–300 U BTX-A (Botox(R zystoskopisch an 30–40 Stellen in den M. detrusor injiziert. Urodynamische Kontrollen erfolgten nach 1, 3 und 6 Monaten. Urodynamisch fand sich ein erhöhtes Reflexvolumen nach 1 Monat um +84 %, nach 3 Monaten um +68 % und nach 6 Monaten um +23 %. Entsprechend verhielten sich die Maximalkapazitäten: +35 % (nach 1 Monat, +23 % (nach 3 Monaten und +36 % (nach 6 Monaten. Die Maximaldrücke veränderten sich im o.g. Zeitraum um –41 %, –22 % bzw. +4 %. Die korrespondierenden Veränderungen der Inkontinenzrate betrug –46 %, –15 % bzw. –13 %. Bei 5 Kindern konnte jedoch auch mit dieser Therapie keine zufriedenstellende Drucksituation sichergestellt werden; nach der daraufhin durchgeführten Blasenaugmentation fanden sich in den Blasenresektaten histomorphologisch typische BTX-A bedingte Veränderungen, die jedoch in ihrer Ausprägung keinen signifikanten Gradienten aufwiesen. Zusammenfassend läßt sich festhalten, daß es nach Botulinumtoxin-A-Injektion in den Detrusormuskel bei der Mehrzahl der Patienten zu einer ausgeprägten und therapeutisch relevanten Verbesserung sämtlicher urodynamischer Parameter bei sehr guter Verträglichkeit des Medikamentes kommt

  13. Limits of a spatial resolution of the cascaded GEM based detectors

    International Nuclear Information System (INIS)

    Kudryavtsev, V.N.; Maltsev, T.V.; Shekhtman, L.I.

    2017-01-01

    Spatial resolution of tracking detectors based on GEM cascades is determined in the simulation and measured. The simulation includes GEANT4 implemented transport of high energy electrons with careful accounting for atomic relaxation processes including emission of fluorescent photons and Auger electrons and custom post-processing taking into account diffusion, gas amplification fluctuations, the distribution of signals over readout electrodes, electronics noise and particular algorithm of final coordinate calculation (centre-of-gravity algorithm). The simulation demonstrates that the minimum of the spatial resolution of about 10–20 μm can be achieved with a gas mixture of Ar-CO 2 (75%–25%) at a strip pitch in the range from 250 μm to 300 μm. At a larger pitch the resolution quickly degrades reaching 70–100 μm at a pitch of 450–500 μm. The reasons of such behavior are discussed and corresponding hypothesis is tested. Particularly, the effect of electron cloud modification due to a GEM operation is considered using the ANSYS and Garfield++ simulation programs. The detection efficiency and spatial resolution of low-material triple-GEM detectors for the DEUTERON facility at BINP are measured at the extracted beam facility of the VEPP-4M collider. One-coordinate resolution of two detectors for the DEUTERON facility is measured with a 2 GeV electron beam. The determined values of the detectors' spatial resolution is equal to 46.6 ± 0.1 μm and 38.5 ± 0.2 μm for orthogonal tracks in two detectors, respectively.

  14. Limits of a spatial resolution of the cascaded GEM based detectors

    Science.gov (United States)

    Kudryavtsev, V. N.; Maltsev, T. V.; Shekhtman, L. I.

    2017-06-01

    Spatial resolution of tracking detectors based on GEM cascades is determined in the simulation and measured. The simulation includes GEANT4 implemented transport of high energy electrons with careful accounting for atomic relaxation processes including emission of fluorescent photons and Auger electrons and custom post-processing taking into account diffusion, gas amplification fluctuations, the distribution of signals over readout electrodes, electronics noise and particular algorithm of final coordinate calculation (centre-of-gravity algorithm). The simulation demonstrates that the minimum of the spatial resolution of about 10-20 μm can be achieved with a gas mixture of Ar-CO2 (75%-25%) at a strip pitch in the range from 250 μm to 300 μm. At a larger pitch the resolution quickly degrades reaching 70-100 μm at a pitch of 450-500 μm. The reasons of such behavior are discussed and corresponding hypothesis is tested. Particularly, the effect of electron cloud modification due to a GEM operation is considered using the ANSYS and Garfield++ simulation programs. The detection efficiency and spatial resolution of low-material triple-GEM detectors for the DEUTERON facility at BINP are measured at the extracted beam facility of the VEPP-4M collider. One-coordinate resolution of two detectors for the DEUTERON facility is measured with a 2 GeV electron beam. The determined values of the detectors' spatial resolution is equal to 46.6 ± 0.1 μm and 38.5 ± 0.2 μm for orthogonal tracks in two detectors, respectively.

  15. Progress on The GEMS (Gravity Electro-Magnetism-Strong) Theory of Field Unification and Its Application to Space Problems

    International Nuclear Information System (INIS)

    Brandenburg, J. E.

    2008-01-01

    Progress on the GEMS (Gravity Electro-Magnetism-Strong), theory is presented as well as its application to space problems. The GEMS theory is now validated through the Standard Model of physics. Derivation of the value of the Gravitation constant based on the observed variation of α with energy: results in the formula G congruent with (ℎ/2π)c/M ηc 2 exp(-1/(1.61α)), where α is the fine structure constant,(ℎ/2π), is Planck's constant, c, is the speed of light, and M ηc is the mass of the η cc Charmonium meson that is shown to be identical to that derived from the GEM postulates. Covariant formulation of the GEM theory is now possible through definition of the spacetime metric tensor as a portion of the EM stress tensor normalized by its own trace: g ab = 4(F c a F cb )/(F ab F ab ), it is found that this results in a massless ground state vacuum and a Newtonian gravitation potential φ = 1/2 E 2 /B 2 . It is also found that a Lorentz or flat-space metric is recovered in the limit of a full spectrum ZPF

  16. hpGEM -- A software framework for discontinuous Galerkin finite element methods

    NARCIS (Netherlands)

    Pesch, L.; Bell, A.; Sollie, W.E.H.; Ambati, V.R.; Bokhove, Onno; van der Vegt, Jacobus J.W.

    2006-01-01

    hpGEM, a novel framework for the implementation of discontinuous Galerkin finite element methods, is described. We present structures and methods that are common for many (discontinuous) finite element methods and show how we have implemented the components as an object-oriented framework. This

  17. Design and Construction of a First Prototype Muon Tomography System with GEM Detectors for the Detection of Nuclear Contraband

    CERN Document Server

    AUTHOR|(CDS)2074269; Grasso, L; Locke, J B; Quintero, A; Mitra, D

    2009-01-01

    Current radiation portal monitors at sea ports and international borders that employ standard radiation detection techniques are not very sensitive to nuclear contraband that is well shielded to absorb emanating radiation. Muon Tomography (MT) based on the measurement of multiple scattering of atmospheric cosmic ray muons traversing cargo or vehicles that contain high-Z material is a promising passive interrogation technique for solving this problem. We report on the design and construction of compact Micro-Pattern Gas Detectors for a small prototype MT station. This station will employ 10 tracking stations based on 30cm x 30cm low-mass triple-GEM detectors with 2D readout. Due to the excellent spatial resolution of GEMs it is sufficient to use a gap of only a few cm between tracking stations. Together with the compact size of the GEM detectors this allows the GEM MT station to be an order of magnitude more compact than MT stations using traditional drift tubes. We present details of the production and assemb...

  18. Serial data acquisition for GEM-2D detector

    International Nuclear Information System (INIS)

    Kolasinski, Piotr; Pozniak, Krzysztof T.; Czarski, Tomasz; Linczuk, Maciej; Byszuk, Adrian; Chernyshova, Maryna; Juszczyk, Bartlomiej; Kasprowicz, Grzegorz; Wojenski, Andrzej; Zabolotny, Wojciech; Zienkiewicz, Pawel; Mazon, Didier; Malard, Philippe; Herrmann, Albrecht; Vezinet, Didier

    2014-01-01

    This article debates about data fast acquisition and histogramming method for the X-ray GEM detector. The whole process of histogramming is performed by FPGA chips (Spartan-6 series from Xilinx). The results of the histogramming process are stored in an internal FPGA memory and then sent to PC. In PC data is merged and processed by MATLAB. The structure of firmware functionality implemented in the FPGAs is described. Examples of test measurements and results are presented. (authors)

  19. Radiation imaging with optically read out GEM-based detectors

    Science.gov (United States)

    Brunbauer, F. M.; Lupberger, M.; Oliveri, E.; Resnati, F.; Ropelewski, L.; Streli, C.; Thuiner, P.; van Stenis, M.

    2018-02-01

    Modern imaging sensors allow for high granularity optical readout of radiation detectors such as MicroPattern Gaseous Detectors (MPGDs). Taking advantage of the high signal amplification factors achievable by MPGD technologies such as Gaseous Electron Multipliers (GEMs), highly sensitive detectors can be realised and employing gas mixtures with strong scintillation yield in the visible wavelength regime, optical readout of such detectors can provide high-resolution event representations. Applications from X-ray imaging to fluoroscopy and tomography profit from the good spatial resolution of optical readout and the possibility to obtain images without the need for extensive reconstruction. Sensitivity to low-energy X-rays and energy resolution permit energy resolved imaging and material distinction in X-ray fluorescence measurements. Additionally, the low material budget of gaseous detectors and the possibility to couple scintillation light to imaging sensors via fibres or mirrors makes optically read out GEMs an ideal candidate for beam monitoring detectors in high energy physics as well as radiotherapy. We present applications and achievements of optically read out GEM-based detectors including high spatial resolution imaging and X-ray fluorescence measurements as an alternative readout approach for MPGDs. A detector concept for low intensity applications such as X-ray crystallography, which maximises detection efficiency with a thick conversion region but mitigates parallax-induced broadening is presented and beam monitoring capabilities of optical readout are explored. Augmenting high resolution 2D projections of particle tracks obtained with optical readout with timing information from fast photon detectors or transparent anodes for charge readout, 3D reconstruction of particle trajectories can be performed and permits the realisation of optically read out time projection chambers. Combining readily available high performance imaging sensors with compatible

  20. Prototype sector magnets for the GeV electron microtron (GEM)

    International Nuclear Information System (INIS)

    Wehrle, R.B.; Norem, J.H.; Praeg, W.F.; Swanstrom, R.H.; Thompson, K.M.

    1983-01-01

    Three prototypes of the sector magnets for GeV Electon Microtron accelerators have been designed. One has been built and two are being constructed. The first is a full scale, 168 ton prototype for one-half of a 2 GeV Double Sided Microtron (DSM) sector magnet. The successful fabrication and testing of the pole pieces for this prototype has demonstrated that their required close tolerances for flatness and parallelism can be met. The second magnet is an approximate two-thirds scale model of one step at the low energy end of the hexatron sector magnet designed for the 4 GeV Electron Microtron (GEM). The measured fields demonstrate that the field falls off faster than an Enge-short-tail and error fields are at low levels and are controllable. A third prototype magnet exactly duplicates the full scale geometry of the first three full orbits of the GEM sector magnet from entrance to exit points. It will permit high precision measurements and corrections of field errors and verify the 3-D computer program, TOSCA

  1. Pasireotid: Eine neue Therapieoption bei Morbus Cushing

    Directory of Open Access Journals (Sweden)

    Luger A

    2012-01-01

    Full Text Available Im Behandlungsalgorithmus des Morbus Cushing war bisher keine zugelassene pharmakologische Behandlungsmöglichkeit verfügbar. Mit dem Multirezeptor-Somatostatinanalogon Pasireotid steht nun mit der im April 2012 erfolgten Zulassung die erste, spezifisch für die Therapie dieses Krankheitsbildes entwickelte Substanz zur Verfügung. Die Studienevidenz belegt eine schnelle und nachhaltige Reduktion der ACTH- und Kortisolproduktion mit klinischer Besserung bei einem Großteil der Patienten.

  2. LHCb: A fast triple-GEM detector for high-rate charged-particle triggering

    CERN Multimedia

    2001-01-01

    - GEM: Principle of Operation - Time Performances - Detector Prototypes and Test Setup - Gas Mixtures - Fields Optimisation - Vgem Optimisation Ar/CO2 (70/30) - Vgem Optimisation Ar/CO2/CF4 (60/20/20) - Time Distributions - Future Tests and Developments

  3. Live event reconstruction in an optically read out GEM-based TPC

    Science.gov (United States)

    Brunbauer, F. M.; Galgóczi, G.; Gonzalez Diaz, D.; Oliveri, E.; Resnati, F.; Ropelewski, L.; Streli, C.; Thuiner, P.; van Stenis, M.

    2018-04-01

    Combining strong signal amplification made possible by Gaseous Electron Multipliers (GEMs) with the high spatial resolution provided by optical readout, highly performing radiation detectors can be realized. An optically read out GEM-based Time Projection Chamber (TPC) is presented. The device permits 3D track reconstruction by combining the 2D projections obtained with a CCD camera with timing information from a photomultiplier tube. Owing to the intuitive 2D representation of the tracks in the images and to automated control, data acquisition and event reconstruction algorithms, the optically read out TPC permits live display of reconstructed tracks in three dimensions. An Ar/CF4 (80/20%) gas mixture was used to maximize scintillation yield in the visible wavelength region matching the quantum efficiency of the camera. The device is integrated in a UHV-grade vessel allowing for precise control of the gas composition and purity. Long term studies in sealed mode operation revealed a minor decrease in the scintillation light intensity.

  4. Studies on GEM modules for a Large Prototype TPC for the ILC

    International Nuclear Information System (INIS)

    Tsionou, Dimitra

    2017-01-01

    The International Linear Collider (ILC) is a future electron–positron collider with centre of mass energy of 500–1000 GeV. The International Large Detector (ILD) is one of two detector concepts at the ILC. Its high precision tracking system consists of Silicon sub-detectors and a Time Projection Chamber (TPC) equipped with micro-pattern gas detectors (MPGDs). Within the framework of the LCTPC collaboration, a Large Prototype (LP) TPC has been built as a demonstrator. This prototype has been equipped with Gas Electron Multiplier (GEM) modules and studied with electron beams of energies 1–6 GeV at the DESY test beam facility. The performance of the prototype detector and the extrapolation to the ILD TPC is presented here. In addition, ongoing optimisation studies and R&D activities in order to prepare the next GEM module iteration are discussed.

  5. Studies on GEM modules for a Large Prototype TPC for the ILC

    Energy Technology Data Exchange (ETDEWEB)

    Tsionou, Dimitra, E-mail: dimitra.tsionou@desy.de

    2017-02-11

    The International Linear Collider (ILC) is a future electron–positron collider with centre of mass energy of 500–1000 GeV. The International Large Detector (ILD) is one of two detector concepts at the ILC. Its high precision tracking system consists of Silicon sub-detectors and a Time Projection Chamber (TPC) equipped with micro-pattern gas detectors (MPGDs). Within the framework of the LCTPC collaboration, a Large Prototype (LP) TPC has been built as a demonstrator. This prototype has been equipped with Gas Electron Multiplier (GEM) modules and studied with electron beams of energies 1–6 GeV at the DESY test beam facility. The performance of the prototype detector and the extrapolation to the ILD TPC is presented here. In addition, ongoing optimisation studies and R&D activities in order to prepare the next GEM module iteration are discussed.

  6. Studies on GEM modules for a large prototype TPC for the ILC

    International Nuclear Information System (INIS)

    Tsionou, Dimitra

    2016-12-01

    The International Linear Collider (ILC) is a future electron-positron collider with centre of mass energy of 500-1000 GeV. The International Large Detector (ILD) is one of two detector concepts at the ILC. Its high precision tracking system consists of Silicon sub-detectors and a Time Projection Chamber (TPC) equipped with micro-pattern gas detectors (MPGDs). Within the framework of the LCTPC collaboration, a Large Prototype (LP) TPC has been built as a demonstrator. This prototype has been equipped with Gas Electron Multiplier (GEM) modules and studied with electron beams of energies 1-6 GeV at the DESY test beam facility. The performance of the prototype detector and the extrapolation to the ILD TPC is presented here. In addition, ongoing optimisation studies and R and D; activities in order to prepare the next GEM module iteration are discussed.

  7. An accurate Kriging-based regional ionospheric model using combined GPS/BeiDou observations

    Science.gov (United States)

    Abdelazeem, Mohamed; Çelik, Rahmi N.; El-Rabbany, Ahmed

    2018-01-01

    In this study, we propose a regional ionospheric model (RIM) based on both of the GPS-only and the combined GPS/BeiDou observations for single-frequency precise point positioning (SF-PPP) users in Europe. GPS/BeiDou observations from 16 reference stations are processed in the zero-difference mode. A least-squares algorithm is developed to determine the vertical total electron content (VTEC) bi-linear function parameters for a 15-minute time interval. The Kriging interpolation method is used to estimate the VTEC values at a 1 ° × 1 ° grid. The resulting RIMs are validated for PPP applications using GNSS observations from another set of stations. The SF-PPP accuracy and convergence time obtained through the proposed RIMs are computed and compared with those obtained through the international GNSS service global ionospheric maps (IGS-GIM). The results show that the RIMs speed up the convergence time and enhance the overall positioning accuracy in comparison with the IGS-GIM model, particularly the combined GPS/BeiDou-based model.

  8. GEM-loaded magnetic albumin nanospheres modified with cetuximab for simultaneous targeting, magnetic resonance imaging, and double-targeted thermochemotherapy of pancreatic cancer cells.

    Science.gov (United States)

    Wang, Ling; An, Yanli; Yuan, Chenyan; Zhang, Hao; Liang, Chen; Ding, Fengan; Gao, Qi; Zhang, Dongsheng

    2015-01-01

    Targeted delivery is a promising strategy to improve the diagnostic imaging and therapeutic effect of cancers. In this paper, novel cetuximab (C225)-conjugated, gemcitabine (GEM)-containing magnetic albumin nanospheres (C225-GEM/MANs) were fabricated and applied as a theranostic nanocarrier to conduct simultaneous targeting, magnetic resonance imaging (MRI), and double-targeted thermochemotherapy against pancreatic cancer cells. Fe3O4 nanoparticles (NPs) and GEM co-loaded albumin nanospheres (GEM/MANs) were prepared, and then C225 was further conjugated to synthesize C225-GEM/MANs. Their morphology, mean particle size, GEM encapsulation ratio, specific cell-binding ability, and thermal dynamic profiles were characterized. The effects of discriminating different EGFR-expressing pancreatic cancer cells (AsPC-1 and MIA PaCa-2) and monitoring cellular targeting effects were assessed by targeted MRI. Lastly, the antitumor efficiency of double/C225/magnetic-targeted and nontargeted thermochemotherapy was compared with chemotherapy alone using 3-(4, 5-dimethyl-2-thiazolyl)-2,5-diphenyl-2H-tetrazolium bromide (MTT) and flow cytometry (FCM) assay. When treated with targeted nanospheres, AsPC-1 cells showed a significantly less intense MRI T2 signal than MIA PaCa-2 cells, while both cells had similar signal strength when incubated with nontargeted nanospheres. T2 signal intensity was significantly lower when magnetic and C225 targeting were combined, rather than used alone. The inhibitory and apoptotic rates of each thermochemotherapy group were significantly higher than those of the chemotherapy-alone groups. Additionally, both MTT and FCM analysis verified that double-targeted thermochemotherapy had the highest targeted killing efficiency among all groups. The C225-GEM/MANs can distinguish various EGFR-expressing live pancreatic cancer cells, monitor diverse cellular targeting effects using targeted MRI imaging, and efficiently mediate double-targeted thermochemotherapy

  9. Analytische Betrachtung des Quantisierungsfehlers bei grundlegenden Rechenoperationen der digitalen Signalverarbeitung

    Directory of Open Access Journals (Sweden)

    W. Schlecker

    2005-01-01

    Full Text Available Bei der Realisierung digitaler Schaltungen mit einem ASIC oder FPGA kann die Wortbreite der Berechnungen frei gewählt werden. Um die Fläche bzw. die benötigte Hardware zu minimieren, wird versucht, die Berechnungen mit minimaler Wortbreite zu implementieren. Dabei muss jedoch das Quantisierungsrauschen, das durch das Beschränken der Wortbreite entsteht, berücksichtigt werden. Häufig wird hierzu eine worst-case Abschätzung des Fehlers gemacht oder mit Simulationen die benötigte Wortbreite bestimmt. Der vorliegende Beitrag betrachtet die Auswirkungen der Quantisierung analytisch. Dabei wird von gleichverteilten Eingangssignalen ausgegangen. Es wird das Quantisierungsrauschen in Abhängigkeit von der Eingangs- und Ausgangswortbreite bei der Multiplikation und beim Skalarprodukt betrachtet. Die Untersuchungen wurden für Runden und für Abschneiden analytisch durchgeführt und durch Simulation bestätigt.

  10. The Forward GEM Tracker of STAR at RHIC

    OpenAIRE

    Simon, F.; Balewski, J.; Fatemi, R.; Hasell, D.; Kelsey, J.; Majka, R.; Page, B.; Plesko, M.; Underwood, D.; Smirnov, N.; Sowinski, J.; Spinka, H.; Surrow, B.; Visser, G.

    2008-01-01

    The STAR experiment at the Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Laboratory (BNL) is in the process of designing and constructing a forward tracking system based on triple GEM technology. This upgrade is necessary to give STAR the capability to reconstruct and identify the charge sign of W bosons over an extended rapidity range through their leptonic decay mode into an electron (positron) and a neutrino. This will allow a detailed study of the flavor-separated spin str...

  11. Design of data acquisition system for GEM detector

    International Nuclear Information System (INIS)

    Lu Jianliang; Chen Ziyu; Shen Ji; Jin Xi

    2011-01-01

    It describes the design and realization of the USB 2.0 high speed data acquisition devise which is used in the readout electronics of the GEM (gas electron multiplier) detector. By using of the USB Microcontroller EZ-USB FX2 CY7C68013A, high speed ADC and FPGA, high-speed data rate of data acquisition and transmission was realized. The data rate reaches to 20 MByte/s, meeting the requirements of data acquisition and transmission of the detector. (authors)

  12. Probleme bei der Digitalisierung analoger Messwerte

    Science.gov (United States)

    Plaßmann, Wilfried

    Messwerte liegen häufig in analoger Form als Spannungswerte vor. Sie werden in eine digital kodierte Form umgesetzt, wenn eine (nahezu) fehlerfreie Übertragung erforderlich ist, wenn Signalverläufe gespeichert werden sollen, wenn eine Weiterverarbeitung erfolgen soll oder wenn Messungen mit sehr geringem Messfehler notwendig sind. Hier soll auf einige Probleme, die durch die Umsetzung entstehen, aus messtechnischer Sicht eingegangen werden. Stichworte: Fehler bei der Digitalisierung; Signal-Quantisierungsgeräusch-Abstand; Verbesserung des Signal-Rausch-Verhältnisses; Abtast-Halte-Glied; Aliasing; Erfassung von Momentanwerten.

  13. A TPC-like readout method for high precision muon-tracking using GEM-detectors

    Energy Technology Data Exchange (ETDEWEB)

    Flierl, Bernhard; Biebel, Otmar; Bortfeldt, Jonathan; Hertenberger, Ralf; Klitzner, Felix; Loesel, Philipp; Mueller, Ralph [Ludwig-Maximilians-Universitaet Muenchen (Germany); Zibell, Andre [Julius-Maximilians-Universitaet Wuerzburg (Germany)

    2016-07-01

    Gaseous electron multiplier (GEM) detectors are well suited for tracking of charged particles. Three dimensional tracking in a single layer can be achieved by application of a time-projection-chamber like readout mode (μTPC), if the drift time of the electrons is measured and the position dependence of the arrival time is used to calculate the inclination angle of the track. To optimize the tracking capabilities for ion tracks drift gas mixtures with low drift velocity have been investigated by measuring tracks of cosmic muons in a compact setup of four GEM-detectors of 100 x 100 x 6 mm{sup 3} active volume each and an angular acceptance of -25 to 25 . The setup consists of three detectors with two-dimensional strip readout layers of 0.4 mm pitch and one detector with a single strip readout layer of 0.25 mm pitch. All strips are readout by APV25 frontend boards and the amplification stage in the detectors consists of three GEM-foils. Tracks are reconstructed by the μTPC-method in one of the detectors and are then compared to the prediction from the other three detectors defined by the center of charge in every detector. We report our study of Argon and Helium based noble gas mixtures with carbon-dioxide as quencher.

  14. Quality assurance of GEM foils in the framework of the TPC upgrade in the ALICE experiment

    CERN Document Server

    Ozcelik, Melih Arslan

    2016-01-01

    In the framework of the TPC upgrade of the ALICE Experiment, new readout chambers will be installed during the LHC long shutdown 2, which is scheduled to start in July 2018. The current MWPCs (Multi Wire Proportional Chambers) will be replaced by readout chambers consisting of GEM (Gas Electron Multipliers) foils in order to meet the increasing readout rate requirements. QA (Quality Assurance) tests on the GEMs are performed to classify the foils. In this report we present the work done during the CERN Summer Student Programme 2016.

  15. Solution Method and Precision Analysis of Double-difference Dynamic Precise Orbit Determination of BeiDou Navigation Satellite System

    Directory of Open Access Journals (Sweden)

    LIU Weiping

    2016-02-01

    Full Text Available To resolve the high relativity between the transverse element of GEO orbit and double-difference ambiguity, the classical double-difference dynamic method is improved and the method, which is to determine precise BeiDou satellite orbit using carrier phase and pseudo-range smoothed by phase, is proposed. The feasibility of the method is discussed and the influence of the method about ambiguity fixing is analyzed. Considering the characteristic of BeiDou, the method, which is to fix double-difference ambiguity of BeiDou satellites by QIF, is derived. The real data analysis shows that the new method, which can reduce the relativity and assure the precision, is better than the classical double-difference dynamic method. The result of ambiguity fixing is well by QIF, but the ambiguity fixing success rate is not high on the whole. So the precision of BeiDou orbit can't be improved clearly after ambiguity fixing.

  16. A new Slow Control and Run Initialization Byte-wise Environment (SCRIBE) for the quality control of mass-produced CMS GEM detectors

    CERN Document Server

    Colafranceschi, Stefano

    2016-01-01

    The CMS collaboration aims at improving the muon trigger and tracking performance at the HL-LHC by installing new Gas Electron Multiplier (GEM) detectors in the endcaps of the CMS experiment. Construction and commissioning of GEM detectors for the first muon endcap stations is ramping up in several laboratories using common quality control protocols. The SCRIBE framework is a scalable and cross-platform web-based application for the RD51 Scalable Readout System (SRS) that controls data acquisition and analyzes data in near real time. It has been developed mainly to simplify and standardize measurements of the GEM detector response uniformities with x-rays across all production sites. SCRIBE works with zero suppression of raw SRS pulse height data. This has increased acquisition rates to 5 kHz for a CMS GEM detector with 3072 strips and allows strip-by-strip response comparisons with a few hours of data taking. SCRIBE also manages parallel data reconstruction to provide near real-time feedback on the detector ...

  17. Analysis of Mechanical Properties for GEM Foil

    CERN Document Server

    Chin, Yuk Ming

    2016-01-01

    In view of new assembly technique of the GEM detector; in which three foils stack is stretched to get the uniform gaps among the foils. We studied the mechanical properties of the foil material. We conditioned the samples in different environments to make them extra dry and wet. As holes are the major source of the charge amplification their deformation can effect the detector performance. Therefore in our studies we also studied at which level of the stress the holes deformation is seen. These tensile and holes deformation studies can help to optimize the stress during detector assembly.

  18. Prognostische Bedeutung der physikalischen Streßechokardiographie bei 3329 ambulanten Patienten (5jährige Langzeitstudie)

    OpenAIRE

    Leischik R; Dworrak B; Gülker H; Littwitz H

    2005-01-01

    Hintergrund und Fragestellung: Die Risikoeinschätzung ambulanter Patienten mit thorakaler Schmerzsymptomatik ist ein wichtiges klinisches Problem. Über die prognostische Bedeutung der physikalischen Streßechokardiographie (SE) bei diesem Patientenkollektiv wurde bis jetzt nicht berichtet. Patienten und Methoden: Um die prognostische Bedeutung der physikalischen Streßechokardiographie bei rein ambulanten Patienten zu untersuchen, wurden 3329 Patienten bezüglich des Auftretens schwerer Erei...

  19. Examination of the somatostatin receptor status in non-medullary thyroid cancer; Untersuchungen zum Somatostatinrezeptor-Status bei nicht-medullaeren Schilddruesenkarzinomen

    Energy Technology Data Exchange (ETDEWEB)

    Goerges, R.; Brandt-Mainz, K.; Bockisch, A. [Essen Univ. (Gesamthochschule) (Germany). Klinik und Poliklinik fuer Nuklearmedizin; Kahaly, G. [Mainz Univ. (Germany). Klinik und Poliklinik fuer Medizin - Endokrinologie und Stoffwechselerkrankungen; Mueller-Brand, J.; Maecke, H. [Kantonsspital Basel (Switzerland). Inst. fuer Nuklearmedizin; Walgenbach, S. [Mainz Univ. (Germany). Klinik und Poliklinik fuer Allgemein- und Abdominalchirurgie; Bruns, C. [Praeklinische Forschung Novartis, Basel (Switzerland); Andreas, J. [Universitaetsklinik Mainz (Germany). Klinik und Poliklinik fuer Nuklearmedizin

    1999-06-01

    Aim: Recent in-vitro and in-vivo studies demonstrated a somatostatin receptor expression in some non-medullary thyroid carcinomas. In this study we investigated the somatostatin receptor status for this particular tumor entity in a larger patient group. Subject and methods: We compared 131-iodine with 111-In-pentetreotide scans in 24 patients with metastasizing, non-medullary thyroid cancer. The findings were correlated with other imaging modalities. Additionally, we performed receptor autoradiography in one patient, octreotide therapy in another patient and administration of 90-Y- and 111-In-DOTATOC in 2 consecutive patients. Results: In the 15 patients with papillary or follicular carcinoma, 111-In-pentetreotide was inferior to 131-I in 8/15, equal in 1/15, and superior in 6/15 patients. In 8/9 of the patients with Huerthle cell cacinoma, metastases showed a 111-In-pentetreotide accumulation of various intensity, while 131-iodine scans were negative except for one patient. 111-In-pentetreotide was equal or superior compared to 201-Tl or 99m-Tc-sestamibi, but for the most part inferior in comparison with 18-F-FDG-PET. The findings of 111-In-pentetreotide scintigraphy correlated well with the receptor autoradiography and the accumulation of DOTATOC, but not with the therapeutic effect of `cold` octreotide on the thyroid cancer metastases. Conclusions: Several metastases of papillary and follicular carcinoma, and the majority of Huerthle cell cancer metastases can express somatostatin receptors. 111-In-pentetreotide scintigraphy is a promising tool for localization of metastases especially in Huerthle cell cancer or if PET is not available, and may be useful for selection of possible candidates, if therapeutic effective {beta}-emitting somatostatin analogues will be available for routine application. (orig.) [Deutsch] Ziel: in aktuellen In-vitro und In-vivo-Untersuchungen wurde eine Somatostatinrezeptor-Expression bei einigen nicht

  20. Surface Features and Cathodoluminescence (CL) Characteristics of Corundum Gems from Eastern of Thailand

    Science.gov (United States)

    Boonsoong, A.

    2017-12-01

    Thailand has long been well known as a supplier of gemstones and also one of the world's color stone centers for decades. The principal gemstones are corundum, garnet and zircon. The corundum deposits of Chanthaburi-Trat Provinces form the most significant ruby-sapphire concentration in Thailand. Corundums are commonly found in secondary deposits (alluvium, elluvial, residual-soil and colluvium deposits as well as stream sediments) with the thickness of the gem-bearing layer varying from 10-100cm and the thickness of the overburden ranging up to 15m. A number of corundum samples were collected from each of the twenty-nine corundum deposits in the Chanthaburi-Trat gem fields, eastern of Thailand. Corundum varies in colour across the region with colours associated with three geographic zones; a western zone, characterized by blue, green and yellow sapphires; a middle zone with blue, green sapphires plus rubies; and an eastern zone yielding mainly rubies. This project has aim to study surface features and characterize the Cathodoluminescence (CL) of corundum gems in the Chanthaburi-Trat gem fields, Thailand. Surfaces of the corundums under a scanning electron microscope show triangular etch features and randomly oriented needle-like patterns. These reveal that the corundums have interacted with the magma during their ascent to the Earth's surface. Surface features attributable to transport and weathering processes are scratches, conchoidal fractures and a spongy surface appearance. Clay minerals and Fe-Ti oxide minerals deposited on the spongy surfaces of some corundums also indicate that these grains experienced chemical weathering or reacted with the soil solution while they were in the alluvium. Cathodoluminescence shows some blue sapphires to exhibit dull blue luminescence. The main cause of the CL appearance of sapphires is likely to be a quench centre, Fe2+ in their structure. The bright red luminescence in corundum reflects a high Cr3+ content and is always

  1. Untersuchungen zum Fettsäurestoffwechsel bei koronarer Herzkrankheit

    OpenAIRE

    Richter, Wolf-Stefan

    2001-01-01

    Die nicht-invasive bildgebende Diagnostik hat bei koronarer Herzkrankheit einen wichtigen Stellenwert für die Diagnosestellung und Therapieplanung. In diesem Zusammenhang liefern nuklearmedizinische Verfahren wichtige Daten zur Gewebsperfusion und erlauben die bildliche Darstellung und Quantifizierung relevanter Details des kardiomyozytären Stoffwechsels. Die quantitativ bedeutendste Methode der nuklearmedizinischen Herzdiagnostik ist die Perfusionsszintigraphie mit Tl-201 oder einem der Tc-9...

  2. Aging measurements on triple-GEM detectors operated with $CF_{4}$- based gas mixtures

    CERN Document Server

    Alfonsi, M; Bencivenni, G; Bonivento, W; Cardini, A; Lener, M P; Murtas, F; Pinci, D; Raspino, D; Saitta, B; De Simone, P

    2004-01-01

    We present the results of a global irradiation test of full size triple-GEM detectors operated with CF/sub 4/-based gas mixtures. This study has been performed in the framework of an R&D activity on detectors for the innermost region of the first muon station of the LHCb experiment. The prototypes have been irradiated at the Calliope facility of the ENEA-Casaccia with a high intensity 1.25 MeV gamma from a /sup 60/Co source. After the irradiation test the detectors performances have been measured with X-rays and with a 3 GeV pion beam at CERN. A SEM analysis on several samples of the detectors has been performed to complete the understanding of the physical processes occurring in the GEM detector during the strong irradiation.

  3. Optical readout of a triple-GEM detector by means of a CMOS sensor

    Energy Technology Data Exchange (ETDEWEB)

    Marafini, M. [INFN Sezione di Roma (Italy); Museo Storico della Fisica e Centro Studi e Ricerche “E. Fermi”, Roma (Italy); Patera, V. [INFN Sezione di Roma (Italy); Museo Storico della Fisica e Centro Studi e Ricerche “E. Fermi”, Roma (Italy); Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); Pinci, D., E-mail: davide.pinci@roma1.infn.it [INFN Sezione di Roma (Italy); Sarti, A. [Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); Dipartimento di Scienze di Base e Applicate per Ingegneria, Sapienza Università di Roma (Italy); Sciubba, A. [INFN Sezione di Roma (Italy); Museo Storico della Fisica e Centro Studi e Ricerche “E. Fermi”, Roma (Italy); Dipartimento di Scienze di Base e Applicate per Ingegneria, Sapienza Università di Roma (Italy); Spiriti, E. [Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy)

    2016-07-11

    In last years, the development of optical sensors has produced objects able to provide very interesting performance. Large granularity is offered along with a very high sensitivity. CMOS sensors with millions of pixels able to detect as few as two or three photons per pixel are commercially available and can be used to read-out the optical signals provided by tracking particle detectors. In this work the results obtained by optically reading-out a triple-GEM detector by a commercial CMOS sensor will be presented. A standard detector was assembled with a transparent window below the third GEM allowing the light to get out. The detector is supplied with an Ar/CF{sub 4} based gas mixture producing 650 nm wavelength photons matching the maximum quantum efficiency of the sensor.

  4. High-resolution laser-projection display system using a grating electromechanical system (GEMS)

    Science.gov (United States)

    Brazas, John C.; Kowarz, Marek W.

    2004-01-01

    Eastman Kodak Company has developed a diffractive-MEMS spatial-light modulator for use in printing and display applications, the grating electromechanical system (GEMS). This modulator contains a linear array of pixels capable of high-speed digital operation, high optical contrast, and good efficiency. The device operation is based on deflection of electromechanical ribbons suspended above a silicon substrate by a series of intermediate supports. When electrostatically actuated, the ribbons conform to the supporting substructure to produce a surface-relief phase grating over a wide active region. The device is designed to be binary, switching between a reflective mirror state having suspended ribbons and a diffractive grating state having ribbons in contact with substrate features. Switching times of less than 50 nanoseconds with sub-nanosecond jitter are made possible by reliable contact-mode operation. The GEMS device can be used as a high-speed digital-optical modulator for a laser-projection display system by collecting the diffracted orders and taking advantage of the low jitter. A color channel is created using a linear array of individually addressable GEMS pixels. A two-dimensional image is produced by sweeping the line image of the array, created by the projection optics, across the display screen. Gray levels in the image are formed using pulse-width modulation (PWM). A high-resolution projection display was developed using three 1080-pixel devices illuminated by red, green, and blue laser-color primaries. The result is an HDTV-format display capable of producing stunning still and motion images with very wide color gamut.

  5. Summary final report: Contract between the Japan atomic power company and the U.S. Department of Energy Improvement of core safety - study on GEM (III)

    International Nuclear Information System (INIS)

    Burke, T.M.; Lucoff, D.M.

    1997-01-01

    This report provides a summary of activities associated with the technical exchange between representatives of the Japan Atomic Power Company (JAPC) and the United States Department of Energy (DOE) regarding the development and testing of Gas Expansion Modules (GEM) at the Fast Flux Test Facility (FFTF). Issuance of this report completes the scope of work defined in the original contract between JAPC and DOE titled ''Study on Improvement of Core Safety - Study on GEM (III).'' Negotiations related to potential modification of the contract are in progress. Under the proposed contract modification, DOE would provide an additional report documenting FFTF pump start tests with GEMs and answer additional JAPC questions related to core safety with and without GEMs

  6. Experiential Engineering through iGEM--An Undergraduate Summer Competition in Synthetic Biology

    Science.gov (United States)

    Mitchell, Rudolph; Dori, Yehudit Judy; Kuldell, Natalie H.

    2011-01-01

    Unlike students in other engineering disciplines, undergraduates in biological engineering typically have limited opportunity to develop design competencies, and even fewer chances to implement their designed projects. The international Genetically Engineered Machines (iGEM) competition is a student Synthetic Biology competition that, in 2009,…

  7. Furosemide urogram in patients with neobladder; Das Diureseurogramm bei Patienten mit Harnblasenersatz

    Energy Technology Data Exchange (ETDEWEB)

    Merkle, E.M. [Univ. Ulm (Germany). Abt. Radiologie; Aschoff, A.J. [Univ. Ulm (Germany). Abt. Radiologie; Bachor, R. [Univ. Ulm (Germany). Abt. fuer Urologie; Vogel, J. [Univ. Ulm (Germany). Abt. Radiologie; Merk, J. [Univ. Ulm (Germany). Abt. Radiologie; Brambs, H.J. [Univ. Ulm (Germany). Abt. Radiologie

    1996-11-01

    Purpose: To differentiate between urodynamically relevant obstruction and functionally unimportant dilation of the upper urinary tract in patients with neobladder using a modified furosemide urogram. Method: An excretory urogram with furosemide loading was carried out in 19 patients with neobladder and sonographically and urographically confirmed dilation of the upper urinary tract. Once strong contrasting of the renal pelves and calyces has been achieved, 20 mg of furosemide were applied and late radiographs were obtained at 15 min and 30 min, respectively. An obstruction was defined as increasing dilation of the renal pelves and calices during forced diuresis and lack of washout effect of the contrast medium. Results: In 32 cases, the renoureteral unit (RUU) was dilated on ultrasound. Of these, 25 RUU`s showed good emptyness of contrast medium upon stimulation of diuresis, six RUU`s returned a borderline findings, while one RUU was found to exhibit a decompensated anastomotic stenosis, which was dilated. Two further patients with bordeline findings were later treated surgically due to their pain symptoms. No patient required further preoperative diagnostic procedures. Conclusions: The modified furosemide urogram represents a cost-effective diagnostic orientation strategy in patients with neobladder and dilated renal pelves and calyses and is both well-tolerated by patients and meets with broad acceptance from the urologic staff. (orig.) [Deutsch] Ziel: Differenzierung zwischen urodynamisch relevanter Obstruktion und funktionell bedeutungsloser Dilatation des oberen Harntraktes bei Patienten mit Harnblasenersatz durch ein modifiziertes Diureseurogramm. Methodik: Bei 19 Patienten mit Harnableitung und sonographisch sowie urographisch nachgewiesener Erweiterung des oberen Harntraktes wurde ein Ausscheidungsurogramm mit Furosemidbelastung durchgefuehrt. Bei kraeftiger Kontrastierung des erweiterten Nierenbeckenkelchsystems (NBKS) wurden 20 mg Furosemid appliziert und

  8. A Aderência dos Pronunciamentos Contábeis do CPC às Normas Internacionais de Contabilidade

    Directory of Open Access Journals (Sweden)

    Jorge Andrade Costa

    2012-09-01

    Full Text Available A convergência para os padrões contábeis internacionais tem se tornado um assunto relevante, com agenda definida para sua adesão em muitos países ao redor do mundo. No Brasil, coube ao CPC a responsabilidade de emitir pronunciamentos contábeis de acordo com as normas IFRS. Cada documento emitido pelo CPC corresponde a uma norma internacional de contabilidade emitida pelo IASB. Este trabalho tem como objetivo comparar os pronunciamentos do CPC com as normas do IASB e verificar a existência de diferenças entre os mesmos. Para tanto, realizou-se uma pesquisa documental aos pronunciamentos do CPC e às normas do IASB. Utilizou-se a técnica da análise de conteúdo, tendo o tema como unidade de significação. O universo de análise compreendeu os 65 pronunciamentos técnicos que estão sendo utilizados nas demonstrações contábeis das companhias brasileiras, emitidos pelo CPC entre os anos de 2007 a 2011. Os resultados apontaram para a existência de diferenças entre os pronunciamentos emitidos pelo CPC e as normas emitidas pelo IASB, as quais foram agrupadas em quatro categorias de análise. Após análise, concluiu-se que as diferenças apontadas não prejudicam a declaração de que as demonstrações contábeis consolidadas brasileiras, preparadas de acordo com os CPCs estão de acordo com as normas do IASB. Palavras-chave: CPC, IFRS, IASB, demonstrações contábeis

  9. Mitbestimmung von Studierenden bei der Qualitätssicherung und Hochschulentwicklung

    DEFF Research Database (Denmark)

    Lippert, Ingmar

    2005-01-01

    Hochschule hat bestimmte Aufgaben. Sie soll durch Forschung und Lehre Wissen und Methoden in die Gesellschaft tragen. Sie soll auch direkt andere gesellschaftliche Institutionen beraten. Bei diesen Interaktionen soll aber – und das ist so spezifisch für Hochschulen – die gesellschaftliche Praxis ...

  10. Ambient water quality in aquifers used for drinking-water supplies, Gem County, southwestern Idaho, 2015

    Science.gov (United States)

    Bartolino, James R.; Hopkins, Candice B.

    2016-12-20

    In recent years, the rapid population growth in Gem County, Idaho, has been similar to other counties in southwestern Idaho, increasing about 54 percent from 1990 to 2015. Because the entire population of the study area depends on groundwater for drinking water supply (either from self-supplied domestic, community, or municipal-supply wells), this population growth, along with changes in land use (including potential petroleum exploration and development), indicated to the public and local officials the need to assess the quality of groundwater used for human consumption. To this end, the U.S. Geological Survey, in cooperation with Gem County and the Idaho Department of Environmental Quality, assessed the quality of groundwater from freshwater aquifers used for domestic supply in Gem County. A total of 47 domestic or municipal wells, 1 spring, and 2 surface-water sites on the Payette River were sampled during September 8–November 19, 2015. The sampled water was analyzed for a variety of constituents, including major ions, trace elements, nutrients, bacteria, radionuclides, dissolved gasses, stable isotopes of water and methane, and either volatile organic compounds (VOCs) or pesticides.To better understand analytical results, a conceptual hydrogeologic framework was developed in which three hydrogeologic units were described: Quaternary-Tertiary deposits (QTd), Tertiary Idaho Group rocks (Tig), and Tertiary-Cretaceous igneous rocks (TKi). Water levels were measured in 30 wells during sampling, and a groundwater-level altitude map was constructed for the QTd and Tig units showing groundwater flow toward the Emmett Valley and Payette River.Analytical results indicate that groundwater in Gem County is generally of good quality. Samples collected from two wells contained water with fluoride concentrations greater than the U.S. Environmental Protection Agency (EPA) Maximum Contaminant Level (MCL) of 4 milligrams per liter (mg/L), six wells contained arsenic at

  11. PET activation in basal ganglia disorders: Parkinson`s disease and dystonia; PET-Aktivierungsstudien bei Basalganglienerkrankungen: Morbus Parkinson und Dystonien

    Energy Technology Data Exchange (ETDEWEB)

    Ceballos-Baumann, A.O. [Neurologische Klinik, Technische Univ. Muenchen (Germany); Boecker, H. [Neurologische Klinik, Technische Univ. Muenchen (Germany); Conrad, B. [Neurologische Klinik, Technische Univ. Muenchen (Germany)

    1997-03-01

    This article reviews PET activation studies with performance of different motor paradigms (joy-stick movements, imagination of movement, writing) in patients with movement disorders. The focus will be on Parkinson`s disease (PD) and dystonia. PET findings will be related to clinical and electrophysiological observations. PET activation studies before and after therapeutic interventions such as pallidotomy in Parkinson`s disease and botulinum toxin in writer`s cramp are described. The contribution of PET activation studies to the understanding of the pathophysiology of dystonia and PD is discussed. (orig.) [Deutsch] Der Beitrag beschreibt verschiedene PET-Aktivierungsstudien mit motorischen Paradigmen (`joystick`-Bewegungen, Vorstellung von Bewegung, Schreiben) bei Bewegungsstoerungen, im wesentlichen bei Patienten mit Dystonie, einer Hyperkinese, und Morbus Parkinson als Hypokinese. Die experimentellen Befunde werden mit der Klinik in Bezug gebracht. Neue Untersuchungen vor und nach therapeutischen Interventionen, wie die stereotaktische Pallidotomie bei Parkinson und die Botulinum-Toxin-Therapie bei Schreibkrampf, werden beschrieben. Der Beitrag von PET-Aktivierungsstudien zum Verstaendnis der Pathophysiologie von Bewegungsstoerungen wird diskutiert. (orig.)

  12. R\\&D results on a CsI-coated triple thick GEM-based photodetector

    CERN Document Server

    Martinengo, P; Paic, G; Paras, D M; Di Mauro, A; van Hoorne, J; Molnar, L; Peskov, V; Breskin, A

    2011-01-01

    The very high momentum particle identification detector proposed for the ALICE upgrade is a focusing RICH using a C(4)F(10) gaseous radiator. For the detection of Cherenkov photons, one of the options currently under investigation is to use a CsI-coated triple thick GEM with metallic or resistive electrodes. We will present results from the laboratory studies as well as preliminary results of beam tests of a RICH detector prototype consisting of a CaF(2) radiator coupled to a 10 x 10 cm(2) CsI-coated triple thick GEM equipped with a pad readout and GASSIPLEX-based front-end electronics. With such a prototype the detection of Cherenkov photons simultaneously with minimum ionizing particles has been achieved for the first time in a stable operation mode. (C) 2010 Elsevier B.V. All rights reserved.

  13. Commissioning and integration testing of the DAQ system for the CMS GEM upgrade

    CERN Document Server

    Castaneda Hernandez, Alfredo Martin

    2017-01-01

    The CMS muon system will undergo a series of upgrades in the coming years to preserve and extend its muon detection capabilities during the High Luminosity LHC.The first of these will be the installation of triple-foil GEM detectors in the CMS forward region with the goal of maintaining trigger rates and preserving good muon reconstruction, even in the expected harsh environment.In 2017 the CMS GEM project is looking to achieve a major milestone in the project with the installation of 5 super-chambers in CMS; this exercise will allow for the study of services installation and commissioning, and integration with the rest of the subsystems for the first time. An overview of the DAQ system will be given with emphasis on the usage during chamber quality control testing, commissioning in CMS, and integration with the central CMS system.

  14. Die Dankesrede bei der Preisverleihung

    Directory of Open Access Journals (Sweden)

    Elenmari Pletikos Olof

    2012-12-01

    Full Text Available Festliche Preisverleihungen sind Gelegenheiten, bei denen von den Preisträgerneine kurze Rede erwartet wird. Obwohl die Dankesrede eine kleinere Randgattung innerhalb des epideiktischen Genres ist, steht sie im Mittelpunkt des Ereignisses. Rhetorikhandbücher geben zahlreiche Ratschläge, wie eine gute Festrede vorbereitet werden soll, um zu unterhalten, zu bewegen und zu belehren. Ziel dieser Untersuchung ist es festzustellen, welche Eigenschaften der Dankesrede die Zuhörer als erwünscht oder unerwünscht wahrnehmen und welche Charakteristika am meisten zur Qualität festlicher Dankesreden beitragen. Das Korpus der gesprochenen Texte bilden 30 Dankesreden anlässlich kroatischer Preisverleihungen in den Bereichen Schauspiel, Sport, Musik, Fernsehen, Literatur und Wirtschaft. Die Audio-Aufnahmen der Dankesreden wurden einer Gruppe von Hörern zur Bewertung in folgenden Kategorien vorgelegt: interessant, geistreich, hoher Sprachstil, feierlich, emotiv, persönlich, originell, bescheiden, vorbereitet und spontan. Zusätzlich wurde zu jeder Rede die offene Frage gestellt, was dem Zuhörer an der Rede gefallen oder nicht gefallen habe. Die Resultate der Perzeptionsanalye lassen erkennen, dass die Interessantheit einer Rede mit der Eigenschaft des Geistreichen, des Originellen, des Emotionalen und des Persönlichen in Verbindung gebracht wird und die Eigenschaft des Festlichen im Wesentlichen nur mit dem hohen Sprachstil und der Vorbereitetheit des Textes korreliert. Einige Eigenschaften können sowohl erwünscht als auch unerwünscht sein, z. B. Dialekt, Persönliches und Kürze. Die besten Dankesreden haben Eigenschaften, die im Grunde schwer miteinander zu verbinden sind: Einerseits soll der Text vorbereitet sein (hoher Stil, Wortwahl, Figuren, Originalität der Geschichte, Humor, andererseits wird bei der Ausführung Spontaneität (Aufrichtigkeit, Emotionalität, Persönlichkeit erwartet.

  15. Summary final report: Contract between the Japan atomic power company and the U.S. Department of Energy Improvement of core safety - study on GEM (III)

    Energy Technology Data Exchange (ETDEWEB)

    Burke, T.M.; Lucoff, D.M.

    1997-03-18

    This report provides a summary of activities associated with the technical exchange between representatives of the Japan Atomic Power Company (JAPC) and the United States Department of Energy (DOE) regarding the development and testing of Gas Expansion Modules (GEM) at the Fast Flux Test Facility (FFTF). Issuance of this report completes the scope of work defined in the original contract between JAPC and DOE titled ''Study on Improvement of Core Safety - Study on GEM (III).'' Negotiations related to potential modification of the contract are in progress. Under the proposed contract modification, DOE would provide an additional report documenting FFTF pump start tests with GEMs and answer additional JAPC questions related to core safety with and without GEMs.

  16. Gasoline, Ethanol and Methanol (GEM) Ternary Blends utilization as an Alternative to Conventional Iraqi Gasoline to Suppress Emitted Sulfur and Lead Components to Environment

    OpenAIRE

    Miqdam Tariq Chaichan

    2016-01-01

    Iraqi conventional gasoline characterized by its low octane number not exceed 82 and high lead and sulfur content. In this paper tri-component or ternary, blends of gasoline, ethanol, and methanol presented as an alternative fuel for Iraqi conventional gasoline. The study conducted by using GEM blend that equals E85 blend in octane rating. The used GEM selected from Turner, 2010 collection. G37 E20 M43 (37% gasoline + 20% ethanol+ 43% methanol) was chosen as GEM in present study. This blend u...

  17. Operation of gas electron multiplier (GEM) with propane gas at low pressure and comparison with tissue-equivalent gas mixtures

    Energy Technology Data Exchange (ETDEWEB)

    De Nardo, L., E-mail: laura.denardo@unipd.it [University of Padova, Physics and Astronomy Department and PD-INFN, via Marzolo 8, I-35131 Padova (Italy); Farahmand, M., E-mail: majid.farahmand@rivm.nl [Centre for Environmental Safety and Security, National Institute for Public Health and the Environment (RIVM), PO Box 1, NL-3720 BA Bilthoven (Netherlands)

    2016-05-21

    A Tissue-Equivalent Proportional Counter (TEPC), based on a single GEM foil of standard geometry, has been tested with pure propane gas at low pressure, in order to simulate a tissue site of about 1 µm equivalent size. In this work, the performance of GEM with propane gas at a pressure of 21 and 28 kPa will be presented. The effective gas gain was measured in various conditions using a {sup 244}Cm alpha source. The dependence of effective gain on the electric field strength along the GEM channel and in the drift and induction region was investigated. A maximum effective gain of about 5×10{sup 3} has been reached. Results obtained in pure propane gas are compared with gas gain measurements in gas mixtures commonly employed in microdosimetry, that is propane and methane based Tissue-Equivalent gas mixtures.

  18. Retrospektive Analyse von Zufallsbefunden, die bei Patienten mit kutanem malignen Malignom durch (18) F-Fluordeoxyglucose-PET/CT erhoben wurden.

    Science.gov (United States)

    Conrad, Franziska; Winkens, Thomas; Kaatz, Martin; Goetze, Steven; Freesmeyer, Martin

    2016-08-01

    Bei der (18) F-Fluordeoxyglucose-Positronenemissionstomographie/Computertomographie (FDG-PET/CT) ergeben sich häufig Zufallsbefunde. In der vorliegenden Studie konzentrierten wir uns auf mittels FDG-PET/CT erhaltene Zufallsbefunde bei Patienten mit kutanem Melanom und überprüften deren Relevanz hinsichtlich weiterer diagnostischer Maßnahmen und Interventionen. Die Krankenakten von 181 konsekutiven Melanom-Patienten wurden retrospektiv ausgewertet, um das Management von Zufallsbefunden zu dokumentieren. Der Schwerpunkt lag dabei auf den histologischen Befunden. Bei 33 von 181 (18 %) Patienten lagen 39 relevante Zufallsbefunde vor, und zwar im Kolorektalbereich (n = 15 Patienten), in der Schilddrüse (n = 8), der Prostata (n = 2), dem Bewegungsapparat (n = 2), in Lymphknoten (n = 2), der Parotis (n = 1), den Mandeln (n = 1), den Nieren (n = 1) und der Gallenblase (n = 1). Bei 25 Patienten schlossen sich weitere diagnostische Verfahren an, wobei in 21 Fällen ein klinisches Korrelat nachgewiesen wurde. Bei 16 von 21 Patienten ergab sich eine Neoplasie, darunter fünf maligne Läsionen (vier Kolonkarzinome und ein Prostatakarzinom). Die Malignome wurden frühzeitig diagnostiziert und in der Mehrzahl der Fälle erfolgreich entfernt. Der Einsatz der FDG-PET/CT als Routine-Diagnostik wird in den Leitlinien empfohlen und ist indiziert bei malignem Melanom ab Stadium IIC. In dieser Studie wurden auf effektive Weise ansonsten nicht erkannte Krebserkrankungen, insbesondere Kolonkarzinome, detektiert. In den meisten Fällen war eine frühe Intervention möglich. Zufallsbefunde durch FDG-PET/CT sollten, unter Berücksichtigung des Zustands und der Wünsche des Patienten, mit den geeigneten diagnostischen Maßnahmen abgeklärt werden. © 2016 Deutsche Dermatologische Gesellschaft (DDG). Published by John Wiley & Sons Ltd.

  19. MRI of the musculature in patients with myalgia - indications and imaging results; MRT der Muskulatur bei Myalgien - Indikationen und Bildbefunde

    Energy Technology Data Exchange (ETDEWEB)

    Beese, M.S. [Universitaetsklinik Hamburg-Eppendorf (Germany). Radiologische Klinik; Winkler, G. [Universitaetsklinik Hamburg-Eppendorf (Germany). Neurologische Klinik; Maas, R. [Universitaetsklinik Hamburg-Eppendorf (Germany). Radiologische Klinik; Buechler, E. [Universitaetsklinik Hamburg-Eppendorf (Germany). Radiologische Klinik

    1996-05-01

    241 patients suffering from myalgic symptoms were examined by axial scans of the muscular system with T1w and STIR-sequences. All patients underwent a complete neuromuscular examination, which included an MRI guided muscle-biopsy of 203 patients. The images were retrospectively analysed as to the typical characteristics of differential diagnosis. In cases of idiopathic or bacterial/viral induced myositis, primary vasculitis, and rhabdomyolysis, edematous changes of the muscles could always be found. Abscesses were only found in bacterial myositis. In cases of poly- and dermatomyositis as well as inclusion-body-myositis, MRI showed a uniform distribution pattern with emphasis on the quadriceps muscles. In contrast to other neuromuscular diseases in bacterial induced myositis, focal myositis, and rhabdomyolysis a strong contrast agent enhancement was seen. All patients with myalgic syndromes without any other additional neuropathological findings and 86% of the patients suffering from polymyalgia rheumatica had normal MR-findings. MRI allows a correct exclusion of an inflammatory, tumorous, or rhabdomyolitic cause of a myalgia and leads to pathognomonic findings for these diseases. Diseases belonging to the group of endocrine, toxic, or metabolic myopathies might be normal in MRI. (orig./MG) [Deutsch] Bei 241 Patienten mit myalgischen Beschwerden wurden axiale Aufnahmen der Muskulatur mit T1w- und STIR-Sequenzen angefertigt. Bei allen Patienten wurde eine vollstaendige neuromuskulaere Untersuchung durchgefuehrt, die bei 203 Patienten eine MRT-gezielte Muskelbiopsie beinhaltete. Das Bildmaterial wurde retrospektiv hinsichtlich differentialdiagnostischer Charakteristika analysiert. Bei idiopathischen und erregerbedingten Myositiden, primaeren Vaskulitiden und bei Rhabdomyolysen bestanden ohne Ausnahme oedematoese Veraenderungen der Muskulatur. Abszessformationen wurden nur bei erregerbedingten Myositiden vorgefunden. Bei Poly- und Dermatomyositiden sowie

  20. Tunable Cascade Reaction of Aryl Diazonium Salts and Trialkylamine: Synthesis of Monofluorinated Arylhydrazones and gem-Difluorinated Azo Compounds.

    Science.gov (United States)

    Guo, Rui; Zhang, Zhengjuan; Shi, Feng; Tang, Pingping

    2016-03-04

    The first example of a mild and tunable cascade reaction of aryl diazonium salts and trialkylamine in the presence of Selectfluor to prepare monofluorinated arylhydrazones and gem-difluorinated azo compounds without metal has been explored. In the presence of H2O, the monofluorinated arylhydrazones were observed in moderate to good yield. In the absence of H2O, the gem-difluorinated azo compounds were obtained. The fluorinated arylhydrazones were utilized to synthesize fluorinated pyrazoles and other nitrogen-containing compounds.

  1. Osteoporose bei Mb. Bechterew - neue Ansätze

    OpenAIRE

    Obermayer-Pietsch B; Aglas F; Hermann J; Leb G; Tauber G

    1999-01-01

    Eine axiale Osteoporose und daraus resultierende vertebrale Kompressionsfrakturen sind häufige Symptome eines Mb. Bechterew (MbB, Spondylarthritis ankylosans). Als ein möglicher genetischer Faktor der Osteoporose wurde eine Assoziation der Knochendichte (BMD) mit BsmI- und FokI-Polymorphismen im Vitamin D-Rezeptor-(VDR-)Gen publiziert. In der vorliegenden Studie wurden die Beziehungen zwischen diesen Polymorphismen, Knochenstoffwechsel, BMD und Aktivitätsindizes bei Patienten mit MbB untersuc...

  2. Magnetic resonance spectroscopy in schizophrenia. Possibilities and limitations; Magnetresonanzspektroskopie bei Schizophrenie. Moeglichkeiten und Grenzen

    Energy Technology Data Exchange (ETDEWEB)

    Wobrock, T. [Universitaetsklinikum des Saarlandes, Homburg/Saar (Germany). Klinik fuer Psychiatrie und Psychotherapie; Universitaetsklinikum des Saarlandes, Klinik fuer Psychiatrie und Psychotherapie, Homburg/Saar (Germany); Scherk, H.; Falkai, P. [Universitaetsklinikum des Saarlandes, Homburg/Saar (Germany). Klinik fuer Psychiatrie und Psychotherapie

    2005-02-01

    Magnetic resonance spectroscopy is a noninvasive investigative technique for in vivo detection of biochemical changes in neuropsychiatric disorders for which especially proton ({sup 1}H-MRS) and phosphorus ({sup 31}P-MRS) magnetic resonance spectroscopy have been used. In this review we explain the principles of MRS and summarize the studies in schizophrenia. A systematic literature review was carried out for {sup 1}H-MRS studies investigating schizophrenic patients compared to controls. The inconsistent results in the cited studies may be due to different study population, specific neuroimaging technique, and selected brain regions. Frequent findings are decreased PME and increased PDE concentrations ({sup 31}P-MRS) linked to altered metabolism of membrane phospholipids and decreased N-acetylaspartate (NAA) or NAA/choline ratio ({sup 1}H-MRS) linked to neuronal damage in frontal (DLPFC) or temporal regions in patients with schizophrenia. These results contribute to the disturbed frontotemporal-thalamic network assumed in schizophrenia and are supported by additional functional neuroimaging, MRI morphometry, and neuropsychological evaluation. The combination of the described investigative techniques with MRS in follow-up studies may provide more specific clues for understanding the pathogenesis and disease course in schizophrenia. (orig.) [German] Die Magnetresonanzspektroskopie (MRS) stellt ein nichtinvasives Verfahren dar, mit dem in vivo biochemische Veraenderungen spezifischer Hirnregionen bei verschiedenen psychiatrischen Erkrankungen untersucht werden koennen. Dabei werden insbesondere die Protonenmagnetresonanzspektroskopie ({sup 1}H-MRS) sowie die Phosphormagnetresonanzspektroskopie ({sup 31}P-MRS) verwendet. In der vorliegenden Uebersichtsarbeit werden die methodischen Grundlagen erlaeutert sowie die Befundlage bei der Schizophrenie referiert. Fuer die Darstellung der Studien zur {sup 1}H-MRS bei schizophrenen Patienten im Vergleich zu einer Kontrollgruppe

  3. STELLAR CORONAE, SOLAR FLARES: A DETAILED COMPARISON OF {sigma} GEM, HR 1099, AND THE SUN IN HIGH-RESOLUTION X-RAYS

    Energy Technology Data Exchange (ETDEWEB)

    Huenemoerder, David P. [Massachusetts Institute of Technology, Kavli Institute for Astrophysics and Space Research, 70 Vassar St., Cambridge, MA 02139 (United States); Phillips, Kenneth J. H. [Visiting Scientist, Space Research Center, Polish Academy of Sciences, 51-622, Kopernika 11, Wroclaw (Poland); Sylwester, Janusz; Sylwester, Barbara, E-mail: dph@space.mit.edu, E-mail: kennethjhphillips@yahoo.com, E-mail: js@cbk.pan.wroc.pl, E-mail: bs@cbk.pan.wroc.pl [Space Research Center, Polish Academy of Sciences, 51-622, Kopernika 11, Wroclaw (Poland)

    2013-05-10

    The Chandra High Energy Transmission Grating Spectrometer (HETG) spectra of the coronally active binary stars {sigma} Gem and HR 1099 are among the highest fluence observations for such systems taken at high spectral resolution in X-rays with this instrument. This allows us to compare their properties in detail to solar flare spectra obtained with the Russian CORONAS-F spacecraft's RESIK instrument at similar resolution in an overlapping bandpass. Here we emphasize the detailed comparisons of the 3.3-6.1 A region (including emission from highly ionized S, Si, Ar, and K) from solar flare spectra to the corresponding {sigma} Gem and HR 1099 spectra. We also model the larger wavelength range of the HETG, from 1.7 to 25 A - having emission lines from Fe, Ca, Ar, Si, Al, Mg, Ne, O, and N-to determine coronal temperatures and abundances. {sigma} Gem is a single-lined coronally active long-period binary which has a very hot corona. HR 1099 is a similar, but shorter period, double-lined system. With very deep HETG exposures we can even study emission from some of the weaker species, such as K, Na, and Al, which are important since they have the lowest first ionization potentials, a parameter well known to be correlated with elemental fractionation in the solar corona. The solar flare temperatures reach Almost-Equal-To 20 MK, comparable to the {sigma} Gem and HR 1099 coronae. During the Chandra exposures, {sigma} Gem was slowly decaying from a flare and its spectrum is well characterized by a collisional ionization equilibrium plasma with a broad temperature distribution ranging from 2 to 60 MK, peaking near 25 MK, but with substantial emission from 50 MK plasma. We have detected K XVIII and Na XI emission which allow us to set limits on their abundances. HR 1099 was also quite variable in X-rays, also in a flare state, but had no detectable K XVIII. These measurements provide new comparisons of solar and stellar coronal abundances, especially at the lowest first

  4. Evaluation of the influence of the TH-GEM detector components in dosimetric measurements of standard mammography beams

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Natália F.; Castro, Maysa C.; Caldas, Linda V.E., E-mail: nsilva@ipen.br, E-mail: maysadecastro@gmail.com, E-mail: fbelonsi@gmail.com, E-mail: lcaldas@ipen.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil); Silva, Tiago F.; Cintra, Felipe B.; Luz, Hugo N. da, E-mail: tfsilva@if.usp.br, E-mail: hugonluz@if.usp.br [Universidade de São Paulo (IF/USP), São Paulo, SP (Brazil). Instituto de Física

    2017-07-01

    GEM detectors have found applications in many areas due to their simplicity of construction, low cost, ruggedness and diversity of shape. A dosimeter with these qualities presents utility in several applications, as for example in diagnostic and therapeutic medicine, industrial radiography and nuclear meters. Furthermore, the high sensitivity provided by GEM detectors may extend their applications in low dose dosimetry. Based on these facts, it may be interesting to produce a prototype of a portable TH-GEM type detector with characteristics suitable for dosimetric use in X-rays with low and medium energies. The precise determination of the dosimeter characteristics is very important for laboratories of instrument calibration, as well as to determine how the various components of the detector may influence on the energy deposited in the sensitive volume. In this work, the results obtained about the influence of each one of the components present in this type of detector in standard mammography beams is presented. The code MCNP5 was used. The results allowed the adaptation of the detector to the desired conditions. (author)

  5. A GEM-TPC in twin configuration for the Super-FRS tracking of heavy ions at FAIR

    Science.gov (United States)

    García, F.; Grahn, T.; Hoffmann, J.; Jokinen, A.; Kaya, C.; Kunkel, J.; Rinta-Antila, S.; Risch, H.; Rusanov, I.; Schmidt, C. J.; Simon, H.; Simons, C.; Turpeinen, R.; Voss, B.; Äystö, J.; Winkler, M.

    2018-03-01

    The GEM-TPC described herein will be part of the standard beam-diagnostics equipment of the Super-FRS. This chamber will provide tracking information for particle identification at rates up to 1 MHz on an event-by-event basis. The key requirements of operation for these chambers are: close to 100% tracking efficiency under conditions of high counting rate, spatial resolution below 1 mm and a superb large dynamic range covering projectiles from Z = 1 up to Z = 92. The current prototype consists of two GEM-TPCs inside a single vessel, which are operating independently and have electrical drift fields in opposite directions. The twin configuration is done by flipping one of the GEM-TPCs on the middle plane with respect to the second one. In order to put this development in context, the evolution of previous prototypes will be described and its performances discussed. Finally, this chamber was tested at the University of Jyväskylä accelerator with proton projectiles and at GSI with Uranium, Xenon, fragments and Carbon beams. The results obtained have shown a position resolution between 120 to 300 μm at moderate counting rate under conditions of full tracking efficiency.

  6. HRCT of the lung in collagen vascular diseases; HRCT der Lunge bei Kollagenosen

    Energy Technology Data Exchange (ETDEWEB)

    Diederich, S. [Inst. fuer Klinische Radiologie, Westfaelische Wilhelms-Univ., Muenster (Germany); Roos, N. [Inst. fuer Klinische Radiologie, Westfaelische Wilhelms-Univ., Muenster (Germany); Schmitz-Linneweber, B. [Medizinische Klinik B, Westfaelische Wilhelms-Univ., Muenster (Germany); Gaubitz, M. [Medizinische Klinik B, Westfaelische Wilhelms-Univ., Muenster (Germany); Peters, P.E. [Inst. fuer Klinische Radiologie, Westfaelische Wilhelms-Univ., Muenster (Germany)

    1996-07-01

    bei progressiver Systemsklerose (PSS, Sklerodermie), systemischem Lupus erythematodes (SLE), `mixed connective tissue disease` (MCTD, Sharp-Syndrom), Sjoegren-Syndrom, Mischkollagenose (`Overlap`syndrom) und rheumatoider Arthritis (RA) werden dargestellt. Ausserdem werden fuer die einzelnen Krankheitsbilder jeweils spezifische Phaenomene erlaeutert wie die Oesophagusbeteiligung bei PSS, akute Pneumonitis oder pulmonale Haemorrhagie bei SLE, lymphoproliferative Erkrankungen beim Sjoegren-Syndrom und nekrobiotische Rundherde bei RA. (orig.)

  7. A Modified Differential Coherent Bit Synchronization Algorithm for BeiDou Weak Signals with Large Frequency Deviation.

    Science.gov (United States)

    Han, Zhifeng; Liu, Jianye; Li, Rongbing; Zeng, Qinghua; Wang, Yi

    2017-07-04

    BeiDou system navigation messages are modulated with a secondary NH (Neumann-Hoffman) code of 1 kbps, where frequent bit transitions limit the coherent integration time to 1 millisecond. Therefore, a bit synchronization algorithm is necessary to obtain bit edges and NH code phases. In order to realize bit synchronization for BeiDou weak signals with large frequency deviation, a bit synchronization algorithm based on differential coherent and maximum likelihood is proposed. Firstly, a differential coherent approach is used to remove the effect of frequency deviation, and the differential delay time is set to be a multiple of bit cycle to remove the influence of NH code. Secondly, the maximum likelihood function detection is used to improve the detection probability of weak signals. Finally, Monte Carlo simulations are conducted to analyze the detection performance of the proposed algorithm compared with a traditional algorithm under the CN0s of 20~40 dB-Hz and different frequency deviations. The results show that the proposed algorithm outperforms the traditional method with a frequency deviation of 50 Hz. This algorithm can remove the effect of BeiDou NH code effectively and weaken the influence of frequency deviation. To confirm the feasibility of the proposed algorithm, real data tests are conducted. The proposed algorithm is suitable for BeiDou weak signal bit synchronization with large frequency deviation.

  8. Taxonomia de distorções contábeis

    Directory of Open Access Journals (Sweden)

    José Humberto da Cruz Cunha

    2017-05-01

    Full Text Available http://dx.doi.org/10.5007/1518-2924.2017v22n49p127 Discute o uso de uma taxonomia de distorções contábeis provenientes de erros e fraudes, voltada para o uso dos auditores na análise dos riscos e escolha dos procedimentos de auditoria. Sua elaboração segue as orientações conceituais da classificação facetada, por meio de levantamento conceitual em pesquisa bibliográfica. A taxonomia apresentada possui como categorias fundamentais as fases da informação, aspectos essenciais, afirmações, ciclos de recursos, subciclos de recursos, distorções contábeis e afirmações (objetivos de auditoria. É apresentada a metodologia de elaboração da taxonomia, bem como a sua aplicabilidade na auditoria contábil como instrumento de organização da informação e do conhecimento. Conclui que, a partir dos exemplos utilizados, é possível afirmar que a taxonomia orienta a análise das distorções como uma trilha de auditoria, padronizando os conceitos identificados na linguagem natural em uma estrutura de classificação padronizada.

  9. Comparison of Experiment and Simulation of the triple GEM-Based Fast Neutron Detector

    International Nuclear Information System (INIS)

    Wang Xiao-Dong; Luo Wen; Zhang Jun-Wei; Yang He-Run; Duan Li-Min; Lu Chen-Gui; Hu Rong-Jiang; Hu Bi-Tao; Zhang Chun-Hui; Yang Lei; Zhou Jian-Rong; An Lv-Xing

    2015-01-01

    A detector for fast neutrons based on a 10 × 10 cm"2 triple gas electron multiplier (GEM) device is developed and tested. A neutron converter, which is a high density polyethylene (HDPE) layer, is combined with the triple GEM detector cathode and placed inside the detector, in the path of the incident neutrons. The detector is tested by obtaining the energy deposition spectrum with an Am Be neutron source in the Institute of Modern Physics (IMP) at Lanzhou. In the present work we report the results of the tests and compare them with those of simulations. The transport of fast neutrons and their interactions with the different materials in the detector are simulated with the GEANT4 code, to understand the experimental results. The detector displays a clear response to the incident fast neutrons. However, an unexpected disagreement in the energy dependence of the response between the simulated and measured spectra is observed. The neutron sources used in our simulation include deuterium-tritium (DT, 14 MeV), deuterium-deuterium (DD, 2.45 MeV), and Am Be sources. The simulation results also show that among the secondary particles generated by the incident neutron, the main contributions to the total energy deposition are from recoil protons induced in hydrogen-rich HDPE or Kapton (GEM material), and activation photons induced by neutron interaction with Ar atoms. Their contributions account for 90% of the total energy deposition. In addition, the dependence of neutron deposited energy spectrum on the composition of the gas mixture is presented. (paper)

  10. Adjuvant chemo- and radiotherapy in gastrointestinal tumors; Adjuvante Chemo- und Strahlentherapie bei gastrointestinalen Tumoren

    Energy Technology Data Exchange (ETDEWEB)

    Sendler, A. [Technische Univ. Muenchen (Germany). Chirurgische Klinik und Poliklinik; Feldmann, H.J. [Technische Univ. Muenchen (Germany). Inst. und Poliklinik fuer Strahlentherapie und Radiologische Onkologie; Fink, U. [Technische Univ. Muenchen (Germany). Chirurgische Klinik und Poliklinik; Molls, M. [Technische Univ. Muenchen (Germany). Inst. und Poliklinik fuer Strahlentherapie und Radiologische Onkologie; Siewert, J.R. [Technische Univ. Muenchen (Germany). Chirurgische Klinik und Poliklinik

    1995-04-21

    In modern surgical oncology, adjuvant therapies are important complementary strategies. In local advanced carcinomas of the gastrointestinal tract, 5-year survival data are still disappointing despite standardized surgery. In this context, it has to be differentiated between adjuvant therapy following complete tumor exstirpation (so-called UICC R{sub 0} resection) and additive therapies following incomplete tumor resections (UICC R{sub 1} or R{sub 2} resection). Modalities in the adjuvant setting are chemotherapy, radiotherapy or the combined radio-/chemotherapy. In esophageal and gastric cancer there is up to now no benefit of postoperative adjuvant therapy. In pancreatic cancer, there are studies indicating a benefit of combined radio-/chemotherapy after complete tumor resection. A standard adjuvant chemotherapeutic treatment is proven in colon cancer stage III (Dukes C) with levamisole and 5-FU. Completely resected rectal carcinoma should be treated postoperatively with combined radio-/chemotherapy. In the common clinical or practical setting, adjuvant therapy is indicated only in locally advanced gastrointestinal tumors following R{sub 0} resection. Postoperative therapy following incomplete tumor resection has its reason only in a palliative intention. (orig.) [Deutsch] Adjuvante Therapiestrategien sind wichtige flankierende Massnahmen der modernen onkologischen Chirurgie, da u.a. die 5-Jahres-Ueberlebensquoten bei lokal fortgeschrittenen Tumoren des Gastrointestinaltraktes nach wie vor unbefriedingend sind. Dabei muss grundsaetzlich zwischen adjuvanten Behandlungen nach kompletter Tumorexstirpation (UICC-R{sub 0}-Resektion) und der additiven Therapie nach palliativer Resektion (UICC-R{sub 1}- oder -R{sub 2}-Resektion) unterschieden werden. Als Modalitaeten kommen Chemotherapie, Strahlentherapie und ihre Kombination in Frage. Bei Oesophagus- und Magenkarzinomen kann derzeit keine gueltige Empfehlung zur adjuvanten Therapie gegeben werden. Die Radio

  11. A time projection chamber with GEM-based readout

    Energy Technology Data Exchange (ETDEWEB)

    Attié, David [CEA Saclay, IRFU, F-91191 Gif-sur-Yvette (France); Behnke, Ties [Deutsches Elektronen-Synchrotron DESY, A Research Centre of the Helmholtz Association, Notkestrasse 85, 22607 Hamburg (Hamburg site) (Germany); Bellerive, Alain [Carleton University, Department of Physics, 1125 Colonel By Drive, Ottawa, ON, Canada K1S 5B6 (Canada); Bezshyyko, Oleg [Taras Shevchenko National University of Kyiv, 64/13, Volodymyrska Street, City of Kyiv 01601 (Ukraine); Bhattacharya, Deb Sankar [CEA Saclay, IRFU, F-91191 Gif-sur-Yvette (France); now at Saha Institute of Nuclear Physics, 1/AF, Sector 1, Bidhan Nagar, Kolkata 700064 (India); Bhattacharya, Purba [Saha Institute of Nuclear Physics, 1/AF, Sector 1, Bidhan Nagar, Kolkata 700064 (India); now at National Institute of Science Education and Research (NISER) Bhubaneswar, P.O. Jatni, Khurda 752050, Odisha (India); Bhattacharya, Sudeb [Saha Institute of Nuclear Physics, 1/AF, Sector 1, Bidhan Nagar, Kolkata 700064 (India); Caiazza, Stefano [Deutsches Elektronen-Synchrotron DESY, A Research Centre of the Helmholtz Association, Notkestrasse 85, 22607 Hamburg (Hamburg site) (Germany); now at Johannes Gutenberg Universität Mainz, Institut für Physik, 55099 Mainz (Germany); Colas, Paul [CEA Saclay, IRFU, F-91191 Gif-sur-Yvette (France); Lentdecker, Gilles De [Inter University ULB-VUB, Av. Fr. Roosevelt 50, B1050 Bruxelles (Belgium); Dehmelt, Klaus [Deutsches Elektronen-Synchrotron DESY, A Research Centre of the Helmholtz Association, Notkestrasse 85, 22607 Hamburg (Hamburg site) (Germany); now at State University of New York at Stony Brook, Department of Physics and Astronomy, Stony Brook, NY 11794-3800 (United States); Desch, Klaus [Universität Bonn, Physikalisches Institut, Nußallee 12, 53115 Bonn (Germany); and others

    2017-06-01

    For the International Large Detector concept at the planned International Linear Collider, the use of time projection chambers (TPC) with micro-pattern gas detector readout as the main tracking detector is investigated. In this paper, results from a prototype TPC, placed in a 1 T solenoidal field and read out with three independent Gas Electron Multiplier (GEM) based readout modules, are reported. The TPC was exposed to a 6 GeV electron beam at the DESY II synchrotron. The efficiency for reconstructing hits, the measurement of the drift velocity, the space point resolution and the control of field inhomogeneities are presented.

  12. A Fast and High-precision Orientation Algorithm for BeiDou Based on Dimensionality Reduction

    Directory of Open Access Journals (Sweden)

    ZHAO Jiaojiao

    2015-05-01

    Full Text Available A fast and high-precision orientation algorithm for BeiDou is proposed by deeply analyzing the constellation characteristics of BeiDou and GEO satellites features.With the advantage of good east-west geometry, the baseline vector candidate values were solved by the GEO satellites observations combined with the dimensionality reduction theory at first.Then, we use the ambiguity function to judge the values in order to obtain the optical baseline vector and get the wide lane integer ambiguities. On this basis, the B1 ambiguities were solved. Finally, the high-precision orientation was estimated by the determinating B1 ambiguities. This new algorithm not only can improve the ill-condition of traditional algorithm, but also can reduce the ambiguity search region to a great extent, thus calculating the integer ambiguities in a single-epoch.The algorithm is simulated by the actual BeiDou ephemeris and the result shows that the method is efficient and fast for orientation. It is capable of very high single-epoch success rate(99.31% and accurate attitude angle (the standard deviation of pitch and heading is respectively 0.07°and 0.13°in a real time and dynamic environment.

  13. Performance verification of the Gravity and Extreme Magnetism Small explorer (GEMS) x-ray polarimeter

    Science.gov (United States)

    Enoto, Teruaki; Black, J. Kevin; Kitaguchi, Takao; Hayato, Asami; Hill, Joanne E.; Jahoda, Keith; Tamagawa, Toru; Kaneko, Kenta; Takeuchi, Yoko; Yoshikawa, Akifumi; Marlowe, Hannah; Griffiths, Scott; Kaaret, Philip E.; Kenward, David; Khalid, Syed

    2014-07-01

    Polarimetry is a powerful tool for astrophysical observations that has yet to be exploited in the X-ray band. For satellite-borne and sounding rocket experiments, we have developed a photoelectric gas polarimeter to measure X-ray polarization in the 2-10 keV range utilizing a time projection chamber (TPC) and advanced micro-pattern gas electron multiplier (GEM) techniques. We carried out performance verification of a flight equivalent unit (1/4 model) which was planned to be launched on the NASA Gravity and Extreme Magnetism Small Explorer (GEMS) satellite. The test was performed at Brookhaven National Laboratory, National Synchrotron Light Source (NSLS) facility in April 2013. The polarimeter was irradiated with linearly-polarized monochromatic X-rays between 2.3 and 10.0 keV and scanned with a collimated beam at 5 different detector positions. After a systematic investigation of the detector response, a modulation factor >=35% above 4 keV was obtained with the expected polarization angle. At energies below 4 keV where the photoelectron track becomes short, diffusion in the region between the GEM and readout strips leaves an asymmetric photoelectron image. A correction method retrieves an expected modulation angle, and the expected modulation factor, ~20% at 2.7 keV. Folding the measured values of modulation through an instrument model gives sensitivity, parameterized by minimum detectable polarization (MDP), nearly identical to that assumed at the preliminary design review (PDR).

  14. Performance Verification of the Gravity and Extreme Magnetism Small Explorer GEMS X-Ray Polarimeter

    Science.gov (United States)

    Enoto, Teruaki; Black, J. Kevin; Kitaguchi, Takao; Hayato, Asami; Hill, Joanne E.; Jahoda, Keith; Tamagawa, Toru; Kanako, Kenta; Takeuchi, Yoko; Yoshikawa, Akifumi; hide

    2014-01-01

    olarimetry is a powerful tool for astrophysical observations that has yet to be exploited in the X-ray band. For satellite-borne and sounding rocket experiments, we have developed a photoelectric gas polarimeter to measure X-ray polarization in the 2-10 keV range utilizing a time projection chamber (TPC) and advanced micro-pattern gas electron multiplier (GEM) techniques. We carried out performance verification of a flight equivalent unit (1/4 model) which was planned to be launched on the NASA Gravity and Extreme Magnetism Small Explorer (GEMS) satellite. The test was performed at Brookhaven National Laboratory, National Synchrotron Light Source (NSLS) facility in April 2013. The polarimeter was irradiated with linearly-polarized monochromatic X-rays between 2.3 and 10.0 keV and scanned with a collimated beam at 5 different detector positions. After a systematic investigation of the detector response, a modulation factor greater than or equal to 35% above 4 keV was obtained with the expected polarization angle. At energies below 4 keV where the photoelectron track becomes short, diffusion in the region between the GEM and readout strips leaves an asymmetric photoelectron image. A correction method retrieves an expected modulation angle, and the expected modulation factor, approximately 20% at 2.7 keV. Folding the measured values of modulation through an instrument model gives sensitivity, parameterized by minimum detectable polarization (MDP), nearly identical to that assumed at the preliminary design review (PDR).

  15. SXR measurement and W transport survey using GEM tomographic system on WEST

    Science.gov (United States)

    Mazon, D.; Jardin, A.; Malard, P.; Chernyshova, M.; Coston, C.; Malard, P.; O'Mullane, M.; Czarski, T.; Malinowski, K.; Faisse, F.; Ferlay, F.; Verger, J. M.; Bec, A.; Larroque, S.; Kasprowicz, G.; Wojenski, A.; Pozniak, K.

    2017-11-01

    Measuring Soft X-Ray (SXR) radiation (0.1-20 keV) of fusion plasmas is a standard way of accessing valuable information on particle transport. Since heavy impurities like tungsten (W) could degrade plasma core performances and cause radiative collapses, it is necessary to develop new diagnostics to be able to monitor the impurity distribution in harsh fusion environments like ITER. A gaseous detector with energy discrimination would be a very good candidate for this purpose. The design and implementation of a new SXR diagnostic developed for the WEST project, based on a triple Gas Electron Multiplier (GEM) detector is presented. This detector works in photon counting mode and presents energy discrimination capabilities. The SXR system is composed of two 1D cameras (vertical and horizontal views respectively), located in the same poloidal cross-section to allow for tomographic reconstruction. An array (20 cm × 2 cm) consists of up to 128 detectors in front of a beryllium pinhole (equipped with a 1 mm diameter diaphragm) inserted at about 50 cm depth inside a cooled thimble in order to retrieve a wide plasma view. Acquisition of low energy spectrum is insured by a helium buffer installed between the pinhole and the detector. Complementary cooling systems (water) are used to maintain a constant temperature (25oC) inside the thimble. Finally a real-time automatic extraction system has been developed to protect the diagnostic during baking phases or any overheating unwanted events. Preliminary simulations of plasma emissivity and W distribution have been performed for WEST using a recently developed synthetic diagnostic coupled to a tomographic algorithm based on the minimum Fisher information (MFI) inversion method. First GEM acquisitions are presented as well as estimation of transport effect in presence of ICRH on W density reconstruction capabilities of the GEM.

  16. Cytogenetic monitoring of personnel occupationally exposed to microwave radiation of GEM radar

    International Nuclear Information System (INIS)

    Garaj-Vrhovac, Vera; Gajski, Goran; Brumen, Vlatka

    2008-01-01

    In the present study we analyzed and followed-up on the DNA damaging effects of microwave radiation of GEM radar equipment within microwave field of 10 μW/cm 2 to 10 mW/cm 2 in personnel occupationally exposed to frequency range of 1.5 GHz to 10.9 GHz. The single cell gel electrophoresis (SCGE)/comet assay as a tool for the bio monitoring of individuals accidentally, environmentally or occupationally exposed to physical or chemical agents was used to evaluate possible genotoxic effect on peripheral human blood lymphocytes. The comet assay is a method that allows efficient determination of single strand breaks (SSB) and double-strand breaks (DSB), as well as alkali-labile sites in the DNA of single cells. The comet assay was carried out under alkaline conditions. We measured the baseline comet assay effect in whole blood samples. Parameter of the comet assay was studied in workers occupationally exposed to microwave radiation of GEM radar and in corresponding unexposed control subjects. It was found that in the subjects who were occupationally exposed to microwave radiation, the levels of DNA damage increased compare to control group and showed interindividual variations. As a measure of DNA damage tail length was used, calculated from the centre of the head and presented in micrometers (μm). Mean value of exposed group was 13.54±1.44 as opposed to control mean value that was 13.15±1.39. Differences between mean tail lengths were statistically significant (P<0.05, ANOVA). The results of this study indicate that individuals occupationally exposed to microwave frequency of GEM radar equipment may experience an increased genotoxic risk, emphasizing the importance of individual bio monitoring, limiting exposure and radiation safety programs. (author)

  17. The 2.3 GHz continuum survey of the GEM project

    Science.gov (United States)

    Tello, C.; Villela, T.; Torres, S.; Bersanelli, M.; Smoot, G. F.; Ferreira, I. S.; Cingoz, A.; Lamb, J.; Barbosa, D.; Perez-Becker, D.; Ricciardi, S.; Currivan, J. A.; Platania, P.; Maino, D.

    2013-08-01

    Context. Determining the spectral and spatial characteristics of the radio continuum of our Galaxy is an experimentally challenging endeavour for improving our understanding of the astrophysics of the interstellar medium. This knowledge has also become of paramount significance for cosmology, since Galactic emission is the main source of astrophysical contamination in measurements of the cosmic microwave background (CMB) radiation on large angular scales. Aims: We present a partial-sky survey of the radio continuum at 2.3GHz within the scope of the Galactic Emission Mapping (GEM) project, an observational program conceived and developed to reveal the large-scale properties of Galactic synchrotron radiation through a set of self-consistent surveys of the radio continuum between 408MHz and 10GHz. Methods: The GEM experiment uses a portable and double-shielded 5.5-m radiotelescope in altazimuthal configuration to map 60-degree-wide declination bands from different observational sites by circularly scanning the sky at zenithal angles of 30° from a constantly rotating platform. The observations were accomplished with a total power receiver, whose front-end high electron mobility transistor (HEMT) amplifier was matched directly to a cylindrical horn at the prime focus of the parabolic reflector. The Moon was used to calibrate the antenna temperature scale and the preparation of the map required direct subtraction and destriping algorithms to remove ground contamination as the most significant source of systematic error. Results: We used 484 h of total intensity observations from two locations in Colombia and Brazil to yield 66% sky coverage from to . The observations in Colombia were obtained with a horizontal HPBW of and a vertical HPBW of . The pointing accuracy was and the RMS sensitivity was 11.42 mK. The observations in Brazil were obtained with a horizontal HPBW of and a vertical HPBW of . The pointing accuracy was and the RMS sensitivity was 8.24 mK. The zero

  18. The Design of Compass/BeiDou Navigation Satellite Terminal for Migrant Bird Research

    Directory of Open Access Journals (Sweden)

    Yaohui Li

    2014-01-01

    Full Text Available A terminal of Compass Navigation Satellite System (CNSS, which can not only support BeiDou-1 and BeiDou-2 but also support Global Positioning System (GPS, is designed to research the activities of the migrant birds, with our novel design of a multiband antenna. By a high-density integration, this terminal is designed with a compact size and light weight. When the terminal is assembled to a whooper swan, its flying trace is recorded by the CNSS, which is in agreement with that of GPS. The flying route map based on the CNSS is useful to check the situation and habit of the migrant bird, which is important for animal protection and bird flu outbreak prediction.

  19. PET/CT in lymphoma patients; PET-CT bei Lymphompatienten

    Energy Technology Data Exchange (ETDEWEB)

    Steinert, H.C. [Universitaetsspital Zuerich, Klinik und Poliklinik fuer Nuklearmedizin (Switzerland)

    2004-11-01

    First results of PET/CT in Hodgkin's disease (HD) and aggressive non-Hodgkin's lymphoma (NHL) are reported. From March 2001 to August 2004 822 PET/CT were performed at our clinic in lymphoma patients for primary staging, restaging after therapy, and diagnosis of recurrence. For coregistration non contrast-enhanced low-dose CT were used. Due to the exact anatomic localization of {sup 18}F-FDG accumulating lesions equivocal or false positive PET findings are avoided. In comparison to contrast enhanced CT, PET/CT has a higher sensitivity and specificity in patients with HD and aggressive NHL. Integration of PET/CT in treatment planning of radiation therapy optimizes the field volume. Even in the initial phase of clinical evaluation, PET/CT has proven useful in staging and restaging of lymphoma. The exact anatomic localization of the PET findings is essential for a precise report, for treatment planning of radiation therapy, and for planning surgical biopsy. (orig.) [German] Erste Ergebnisse der PET-CT bei Morbus Hodgkin (HD) und den aggressiven Non-Hodgkin-Lymphomen (NHL) werden beschrieben. Von Maerz 2001 bis August 2004 wurden 822 PET-CT bei Lymphompatienten zum primaeren Staging, zum Restaging nach Therapie und zur Rezidivdiagnostik an unserer Klinik durchgefuehrt. Fuer die Koregistration wurde ein Low-dose-CT ohne i.v.-Kontrastmittel verwendet. Durch die exakte anatomische Zuordnung der {sup 18}F-FDG aufnehmenden Laesionen wurden unklare oder falsch-positive PET-Befunde vermieden. Die PET-CT erzielte im Vergleich zur KM-verstaerkten CT eine hoehere Sensitivitaet und Spezifitaet bei Patienten mit HD und aggressiven NHL. Die Integration der PET-CT in die Planung der Strahlentherapie fuehrte zu einer Optimierung der Feldgrenzen. Die PET-CT hat sich bereits in der Phase der initialen klinischen Evaluation als wertvoll beim Staging und Restaging von Lymphomen erwiesen. Die exakte anatomische Zuordnung der PET-Informationen ist fuer eine sichere Befundung

  20. Modified double contrast-enhanced examination of the stomach of adipose patients after vertical gastroplasty; Modifizierte Doppelkontrast-Untersuchung des Magens bei adipoesen Patienten nach vertikaler Gastroplastie

    Energy Technology Data Exchange (ETDEWEB)

    Raissaki, M.T. [Institut fuer Bildgebende Diagnostik, Universitaetsklinik Heraklion (Greece); Prassopoulos, P. [Institut fuer Bildgebende Diagnostik, Universitaetsklinik Heraklion (Greece); Hatjidakis, A.A. [Institut fuer Bildgebende Diagnostik, Universitaetsklinik Heraklion (Greece); Christodoulakis, M. [Klinik fuer Chirurgische Onkologie der Universitaetsklinik Heraklion (Greece); Melissas, J. [Klinik fuer Chirurgische Onkologie der Universitaetsklinik Heraklion (Greece); Gourtsoyiannis, N.C. [Institut fuer Bildgebende Diagnostik, Universitaetsklinik Heraklion (Greece)

    1995-11-01

    The study reported covers 28 patients who were examined once by radiology before surgery, and twice after surgery. The first post-surgery examination was done on days 5-7, the second during the 4th until 6th month after surgery. For the first examination, water-soluble contrast agent was initially applied, then barium containing contrast agent. The second examination was done by modified double contrast technique. The most frequent, pre-surgery findings revealed gastro-esophageal reflux in 13 patients. The first post-surgery control detected a somastenosis in 2 patients, while the second control examination detected complications of various nature in 11 patients and gastro-esophageal reflux in 5 patients. In 6 patients, discrepancy between clinical and radiological findings was stated. The pouch size did not correlate with the frequency of complications, or with the body-to-mass index decrease. The examination method proposed in this article yields pre-surgery information on the anatomy of the stomach, more accurate dewscription of post-surgery complications, and better evaluation of the antireflux effect of the vertical gastroplasty. (orig.) [Deutsch] In der Studie wurden 28 Patienten einmal praeoperativ und zweimal postoperativ roentgenologisch kontrolliert. Die erste postoperative Kontrolle fand am 5.-7. Tag und die zweite im 4.-6. Monat nach dem Eingriff statt. Bei der ersten Kontrolle wurde zuerst wasserloesliches und anschliessend bariumhaltiges Kontrastmittel benutzt, waehrend bei der zweiten Kontrolle eine modifizierte Doppelkontrast-Untersuchung durchgefuehrt wurde. Der haeufigste praeoperative Befund war der gastrooesophageale Reflux bei 13 Patienten. Bei der ersten praeoperativen Kontrolle fand sich bei 2 Patienten eine Stomastenose, waehrend bei der zweiten verschiedene Komplikationen bei 11 sowie gastrooesophagealer Reflux bei 5 Patienten vorlagen. Eine Diskrepanz zwischen radiologischen und klinischen Befunden fanden wir bei 6 Patienten. Die

  1. Om jazz og race i dansk jazzkritik: nogle eksempler

    DEFF Research Database (Denmark)

    Thomsen, Christen Kold

    2010-01-01

    'Race' bliver i dansk jazzkritik, især fra 50erne og frem, ignoreret som et ydre 'sociologisk' faktum, i modsætning til kulturradiklisternes idealisering før 2. verdenskrig af musikernes 'race' . Men faktisk fortsætter begrebet med at spille en uerkendt rolle, ofte som kvalitets- og stilmarkør i ...

  2. Stages of Psychometric Measure Development: The Example of the Generalized Expertise Measure (GEM)

    Science.gov (United States)

    Germain, Marie-Line

    2006-01-01

    This paper chronicles the steps, methods, and presents hypothetical results of quantitative and qualitative studies being conducted to develop a Generalized Expertise Measure (GEM). Per Hinkin (1995), the stages of scale development are domain and item generation, content expert validation, and pilot test. Content/face validity and internal…

  3. Intra- und postoperative Komplikationen bei Patienten mit roboterassistierter laparoskopischer radikaler Prostatektomie (RALP. Eine Analyse von 3000 konsekutiven Fällen

    Directory of Open Access Journals (Sweden)

    Zugor V

    2012-01-01

    Full Text Available Einleitung: Das Ziel dieser Studie ist es, die intra- und postoperativen Komplikationen bei Patienten mit roboterassistierter laparoskopischer radikaler Prostatektomie anhand von 3000 konsekutiven Fällen aufzuzeigen. Material und Methoden:3000 Männer, welche sich einer RALP unterzogen, wurden retrospektiv untersucht. Alle Patienten wurden sowohl hinsichtlich ihrer intra- als auch postoperativen Komplikationen beobachtet. Postoperative Komplikationen und Re-Interventionen wurden bis 30 Tage nach OP erfasst und anhand der Clavien-Klassifikation in „Minor“- (Clavien-Klassifikation I–IIIa und „Major“- Komplikationen (Clavien-Klassifikation IIIb–IVa eingeteilt. Ergebnisse: Die intraoperativen Komplikationen sind ebenso wie die „minor“ und „major“ postoperativen Komplikationen in Tabellen 3 und 4 aufgeführt. Das mediane Alter der Patienten betrug 64,1 Jahre, der mediane BMI 26,7 kg/m2 , das mediane Prostatagewicht 40,1 g und der mediane PSA-Wert 10,1 ng/ml. Der Gleason-Score bei Biopsie war in 65 % kleiner als 7, in 34,4 % gleich 7 und größer als 7 in 9,6 % der Fälle. Die Lymphknotendissektion wurde in 75,9 % durchgeführt. Ein organbeschränktes Stadium zeigte sich in 75 % und eine extraprostatische Ausbreitung in 25 %. Die gesamte intraoperative Komplikationsrate lag bei 5,1 %, die „minor“ postoperative Komplikationsrate bei 16,1 % und die „major“ bei 1,8 %. Zusammenfassung: Die RALP ist nicht komplikationslos. In erfahrenen Händen ist sie jedoch ein sicheres chirurgisches Verfahren mit einer niedrigen Morbidität und Mortalität.

  4. T-Zell-Zytokinexpression bei gestillten vs. nicht-gestillten Kindern

    OpenAIRE

    Aulenbach, Julia

    2015-01-01

    Das Bestreben, den Aufbau, die Funktion sowie die Entwicklung des Immunsystems zu verstehen, steht schon lange Zeit im Zentrum des Interesses vieler Forschungsarbeiten, insbesondere um auf Grundlage der gewonnenen Erkenntnisse neue Behandlungsansätze für immunologisch relevante Krankheitsbilder zu entwickeln. Stillen könnte ein wichtiger Faktor sein, der bei der Entwicklung und Differenzierung von T-Zell-Subpopulationen und Zytokinmustern im Säuglings- und Kindesalter eine bedeutende Roll...

  5. Experimental study on the precise orbit determination of the BeiDou navigation satellite system.

    Science.gov (United States)

    He, Lina; Ge, Maorong; Wang, Jiexian; Wickert, Jens; Schuh, Harald

    2013-03-01

    The regional service of the Chinese BeiDou satellite navigation system is now in operation with a constellation including five Geostationary Earth Orbit satellites (GEO), five Inclined Geosynchronous Orbit (IGSO) satellites and four Medium Earth Orbit (MEO) satellites. Besides the standard positioning service with positioning accuracy of about 10 m, both precise relative positioning and precise point positioning are already demonstrated. As is well known, precise orbit and clock determination is essential in enhancing precise positioning services. To improve the satellite orbits of the BeiDou regional system, we concentrate on the impact of the tracking geometry and the involvement of MEOs, and on the effect of integer ambiguity resolution as well. About seven weeks of data collected at the BeiDou Experimental Test Service (BETS) network is employed in this experimental study. Several tracking scenarios are defined, various processing schemata are designed and carried out; and then, the estimates are compared and analyzed in detail. The results show that GEO orbits, especially the along-track component, can be significantly improved by extending the tracking network in China along longitude direction, whereas IGSOs gain more improvement if the tracking network extends in latitude. The involvement of MEOs and ambiguity-fixing also make the orbits better.

  6. GEM-loaded magnetic albumin nanospheres modified with cetuximab for simultaneous targeting, magnetic resonance imaging, and double-targeted thermochemotherapy of pancreatic cancer cells

    Directory of Open Access Journals (Sweden)

    Wang L

    2015-03-01

    Full Text Available Ling Wang,1 Yanli An,2 Chenyan Yuan,3 Hao Zhang,2 Chen Liang,2 Fengan Ding,2 Qi Gao,1 Dongsheng Zhang4 1Department of Ultrasonography, Zhong Da Hospital, Medical School, Southeast University, Nanjing, People’s Republic of China; 2Medical School, Southeast University, Nanjing, People’s Republic of China; 3Department of Clinical Laboratory, Zhong Da Hospital, Medical School, Southeast University, Nanjing, People’s Republic of China; 4Jiangsu Key Laboratory for Biomaterials and Devices, Medical School, Southeast University, Nanjing, People’s Republic of China Background: Targeted delivery is a promising strategy to improve the diagnostic imaging and therapeutic effect of cancers. In this paper, novel cetuximab (C225-conjugated, gemcitabine (GEM-containing magnetic albumin nanospheres (C225-GEM/MANs were fabricated and applied as a theranostic nanocarrier to conduct simultaneous targeting, magnetic resonance imaging (MRI, and double-targeted thermochemotherapy against pancreatic cancer cells. Methods: Fe3O4 nanoparticles (NPs and GEM co-loaded albumin nanospheres (GEM/MANs were prepared, and then C225 was further conjugated to synthesize C225-GEM/MANs. Their morphology, mean particle size, GEM encapsulation ratio, specific cell-binding ability, and thermal dynamic profiles were characterized. The effects of discriminating different EGFR-expressing pancreatic cancer cells (AsPC-1 and MIA PaCa-2 and monitoring cellular targeting effects were assessed by targeted MRI. Lastly, the antitumor efficiency of double/C225/magnetic-targeted and nontargeted thermochemotherapy was compared with chemotherapy alone using 3-(4, 5-dimethyl-2-thiazolyl-2,5-diphenyl-2H-tetrazolium bromide (MTT and flow cytometry (FCM assay. Results: When treated with targeted nanospheres, AsPC-1 cells showed a significantly less intense MRI T2 signal than MIA PaCa-2 cells, while both cells had similar signal strength when incubated with nontargeted nanospheres. T2 signal

  7. X-ray Polarization from Black Holes: GEMS Scientific White Paper

    OpenAIRE

    Schnittman, Jeremy; Angelini, Lorella; Baring, Matthew; Baumgartner, Wayne; Black, Kevin; Dotson, Jessie; Ghosh, Pranab; Harding, Alice; Hill, Joanne; Jahoda, Keith; Kaaret, Phillip; Kallman, Tim; Krawczynski, Henric; Krolik, Julian; Lai, Dong

    2013-01-01

    We present here a summary of the scientific goals behind the Gravity and Extreme Magnetism SMEX (GEMS) X-ray polarimetry mission's black hole (BH) observing program. The primary targets can be divided into two classes: stellar-mass galactic BHs in accreting binaries, and super-massive BHs in the centers of active galactic nuclei (AGN). The stellar-mass BHs can in turn be divided into various X-ray spectral states: thermal-dominant (disk), hard (radio jet), and steep power-law (hot corona). Th...

  8. The R + D transfer in Spain: diagnostic based 2006 GEM

    International Nuclear Information System (INIS)

    Coduras Martinez, A.; Urbano Pulido, D.; Ruiz Navarro, J.

    2007-01-01

    The main purpose of this research is to analyse in the international context the situation today of the Spanish R and D transference from the scientific field to the firms, using 2006 GEM data as well as complementary data sources. The main findings of the study emphasize a difficult scenario concerning the R and D transference to the Spanish enterprises. Although these negative results, some data suggest a significant improvement in this area in the near future. (Author) 9 refs

  9. Penile angiography and superselective embolization therapy in arterial priapism; Penisangiographie und superselektive Embolisationstherapie bei high-flow Priapismus

    Energy Technology Data Exchange (ETDEWEB)

    Dinkel, H.P.; Triller, J. [Inst. fuer Diagnostische Radiologie, Inselspital, Univ. Bern (Switzerland); Hochreiter, W. [Urologische Klinik, Inselspital, Univ. Bern (Switzerland)

    2003-08-01

    Purpose: To report feasibility, benefit and complications of penile angiography and superselective penile embolization in arterial priapism. Materials and Methods: Four consecutive patients (aged 28, 29, 40 and 49 years), who underwent penile angiography for arterial priapism (high-flow priapism) within a four-year period, were identified by a keyword search of our radiology information system. One patient had sustained a direct penile trauma (severe blow to the erected penis) and three patients suffered from recurrent spontaneous priapism. All patients had previously undergone corporeal aspiration and noradrenaline injection to achieve detumescence. Two patients had one or several unsuccessful spongiocavernous shunt procedures. Results: In three of the four patients, superselective pudendal and penile angiography demonstrated pathologic arteriocavernous shunting. In two of the three patients, superselective embolization using a coaxial micro-catheter was attempted. In one of the two patients, the cavernous artery became spastic before embolization material was actually injected, inducing immediate and lasting detumescence. In the other patient, unilateral Gelfoam embolization led to immediate detumescence but the priapism recurred 12 hours after the procedure. A subsequent contralateral Gelfoam embolization was successful. Erectile function was preserved in all cases. No procedure-related complications occurred. Conclusion: Our experience supports the prevailing opinion found in the current literature that superselective coaxial embolization constitutes the treatment of choice in patients with high-flow priapism. Prognosis is good with high probability of preserving the erectile function. (orig.) [German] Ziel: Untersuchung der Interventionsmoeglichkeiten bei arteriellem (high-flow) Priapismus durch endovaskulaere superselektive Embolisation der Penisarterien. Methode: Alle innerhalb eines Vierjahreszeitraums (1/99-5/2002) wegen Priapismus zur Angiographie

  10. Rezidivierende Endometriose bei Kinderwunsch: Operieren oder stimulieren?

    Directory of Open Access Journals (Sweden)

    Brunbauer M

    2012-01-01

    Full Text Available Kurzfassung: Endometriose ist neben dem Tubenverschluss und dem PCO-Syndrom eine der Hauptursachen für reduzierte Fertilität bei der Frau. Zur eindeutigen Diagnosesicherung ist die operative Diagnostik Standard. Eine Sanierung ist in vielen Fällen in der gleichen Sitzung möglich. Um nichts unnötig zu (zer- stören, sei die Maxime: eher weniger als mehr. Ein Rezidiv bedeutet eine weitere Reduktion der Schwangerschaftsrate. Eine Zweitoperation kann zwar Beschwerden lindern, verbessert aber die Spontan-Schwangerschaftsrate nur gering. Der Zweiteingriff ist also bezüglich der reinen Schwangerschaftsrate einer modernen IVF-Behandlung eindeutig unterlegen.

  11. Neurofunctional MRI at high magnetic fields; Neurofunktionelle MRT bei hohen Feldern

    Energy Technology Data Exchange (ETDEWEB)

    Speck, O. [Fakultaet fuer Naturwissenschaften, Otto-von-Guericke Universitaet Magdeburg, Abteilung Biomedizinische Magnetresonanz, Institut fuer Experimentelle Physik, Magdeburg (Germany); Leibniz Institut fuer Neurobiologie, Magdeburg (Germany); Deutsches Zentrum fuer Neurodegenerative Erkrankungen (DZNE), Magdeburg (Germany); Center for Behavioral Brain Sciences (CBBS), Magdeburg (Germany); Turner, R. [MPI fuer Kognitions- und Neurowissenschaften, Abteilung Neurophysik, Leipzig (Germany)

    2013-05-15

    group data without the need for voxel-based congruence. (orig.) [German] fMRT-Untersuchungen sind durch den geringen aktivierungsinduzierten Signalunterschied in ihrer Sensitivitaet limitiert und innerhalb kurzer tolerierbarer Messzeiten ist die raeumliche Aufloesung limitiert. fMRT bei 1,5 und mehr noch bei 3 T ist ein zuverlaessiges Werkzeug in der Neurowissenschaft und fuer klinische Anwendungen, wie etwa die praechirurgische Funktionslokalisierung. Die fMRT-Sensitivitaet steigt stark (mehr als linear) mit hoeherer Magnetfeldstaerke. Dies war seit Jahren einer der Hauptgruende fuer die Entwicklung zu hoeheren Feldern wie etwa 7 T. Der Sensitivitaetsgewinn von 7 gegenueber 3 T ist bei hoher raeumlicher Aufloesung am groessten und die fMRT mit sehr hoher isotroper Submillimeteraufloesung wird moeglich. Bisherige Resultate zeigen, dass die Blood-oxygenation-level-dependent(BOLD)-Lokalisierung deutlich praeziser ist als bislang angenommen. Mittels Hochfeld-fMRT werden nicht nur quantitativ bessere Ergebnisse erzielt, sondern Informationen neuer Qualitaet zugaenglich wie etwa die kolumnare und schichtabhaengige Struktur des Kortex. Somit wird der Weg zu weiteren Informationen, wie etwa die Richtung kortikaler Verbindungen, eroeffnet. Diese Moeglichkeiten bergen jedoch auch neue Herausforderungen. So muessen neue Verfahren zur Prozessierung derart hochaufgeloester Daten entwickelt werden, welche z. B. ohne Glaettung auskommen, um den Informationsgehalt der Daten nicht zu reduzieren. Standardaufloesungen von 2-3 mm sind weiterhin bei 3 T ''gut aufgehoben'' und profitieren von geringeren Signalausloeschungen, weniger Verzerrungen und geringerer Lautstaerke. Zum Erreichen hoechster Aufloesung bei 7 T sind parallele Bildgebung und Verzerrungskorrektur essenziell und ermoeglichen eine gute Uebereinstimmung mit anatomischen Aufnahmen. Die Echozeit sollte bei 7 T auf ca. 20-25 ms angepasst und die Datenauswertung fuer einzelne Probanden oder Patienten ohne

  12. Depletion of pro-oncogenic RUNX2 enhances gemcitabine (GEM) sensitivity of p53-mutated pancreatic cancer Panc-1 cells through the induction of pro-apoptotic TAp63.

    Science.gov (United States)

    Ozaki, Toshinori; Nakamura, Mizuyo; Ogata, Takehiro; Sang, Meijie; Yoda, Hiroyuki; Hiraoka, Kiriko; Sang, Meixiang; Shimozato, Osamu

    2016-11-01

    Recently, we have described that siRNA-mediated silencing of runt-related transcription factor 2 (RUNX2) improves anti-cancer drug gemcitabine (GEM) sensitivity of p53-deficient human pancreatic cancer AsPC-1 cells through the augmentation of p53 family TAp63-dependent cell death pathway. In this manuscript, we have extended our study to p53-mutated human pancreatic cancer Panc-1 cells. According to our present results, knockdown of mutant p53 alone had a marginal effect on GEM-mediated cell death of Panc-1 cells. We then sought to deplete RUNX2 using siRNA in Panc-1 cells and examined its effect on GEM sensitivity. Under our experimental conditions, RUNX2 knockdown caused a significant enhancement of GEM sensitivity of Panc-1 cells. Notably, GEM-mediated induction of TAp63 but not of TAp73 was further stimulated in RUNX2-depleted Panc-1 cells, indicating that, like AsPC-1 cells, TAp63 might play a pivotal role in the regulation of GEM sensitivity of Panc-1 cells. Consistent with this notion, forced expression of TAp63α in Panc-1 cells promoted cell cycle arrest and/or cell death, and massively increased luciferase activities driven by TAp63-target gene promoters such as p21WAF1 and NOXA. In addition, immunoprecipitation experiments indicated that RUNX2 forms a complex with TAp63 in Panc-1 cells. Taken together, our current observations strongly suggest that depletion of RUNX2 enhances the cytotoxic effect of GEM on p53-mutated Panc-1 cells through the stimulation of TAp63-dependent cell death pathway even in the presence of a large amount of pro-oncogenic mutant p53, and might provide an attractive strategy to treat pancreatic cancer patients with p53 mutations.

  13. Glycemic load, exercise, and monitoring blood glucose (GEM): A paradigm shift in the treatment of type 2 diabetes mellitus.

    Science.gov (United States)

    Cox, Daniel J; Taylor, Ann G; Singh, Harsimran; Moncrief, Matthew; Diamond, Anne; Yancy, William S; Hegde, Shefali; McCall, Anthony L

    2016-01-01

    This preliminary RCT investigated whether an integrated lifestyle modification program that focuses on reducing postprandial blood glucose through replacing high with low glycemic load foods and increasing routine physical activities guided by systematic self-monitoring of blood glucose (GEM) could improve metabolic control of adults with type 2 diabetes mellitus, without compromising other physiological parameters. Forty-seven adults (mean age 55.3 years) who were diagnosed with type 2 diabetes mellitus for less than 5 years (mean 2.1 years), had HbA1c ≥ 7% (mean 8.4%) and were not taking blood glucose lowering medications, were randomized to routine care or five 1-h instructional sessions of GEM. Assessments at baseline and 6 months included a physical exam, metabolic and lipid panels, and psychological questionnaires. The GEM intervention led to significant improvements in HbA1c (decreasing from 8.4 to 7.4% [69-57 mmol/mol] compared with 8.3 to 8.3% [68-68 mmol/mol] for routine care; Interaction ptype 2 diabetes mellitus. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  14. ENED-GEM: A Conceptual Framework Model for Psychological Enjoyment Factors and Learning Mechanisms in Educational Games about the Environment

    Science.gov (United States)

    Fjællingsdal, Kristoffer S.; Klöckner, Christian A.

    2017-01-01

    Based on a thorough review of psychological literature, this article seeks to develop a model of game enjoyment and environmental learning (ENvironmental EDucational Game Enjoyment Model, ENED-GEM) and delineate psychological processes that might facilitate learning and inspire behavioral change from educational games about the environment. A critically acclaimed digital educational game about environmental issues (Fate of the World by Red Redemption/Soothsayer Games) was used as a case study. Two hundred forty-nine reviews of the game from the popular gaming and reviewing platform known as Steam were analyzed by means of a thematic content analysis in order to identify key player enjoyment factors believed to be relevant to the process of learning from games, as well as to gain an understanding of positive and negative impressions about the game’s general content. The end results of the thematic analysis were measured up to the suggested ENED-GEM framework. Initial results generally support the main elements of the ENED-GEM, and future research into the importance of these individual core factors is outlined. PMID:28701988

  15. ENED-GEM: A Conceptual Framework Model for Psychological Enjoyment Factors and Learning Mechanisms in Educational Games about the Environment

    Directory of Open Access Journals (Sweden)

    Kristoffer S. Fjællingsdal

    2017-06-01

    Full Text Available Based on a thorough review of psychological literature, this article seeks to develop a model of game enjoyment and environmental learning (ENvironmental EDucational Game Enjoyment Model, ENED-GEM and delineate psychological processes that might facilitate learning and inspire behavioral change from educational games about the environment. A critically acclaimed digital educational game about environmental issues (Fate of the World by Red Redemption/Soothsayer Games was used as a case study. Two hundred forty-nine reviews of the game from the popular gaming and reviewing platform known as Steam were analyzed by means of a thematic content analysis in order to identify key player enjoyment factors believed to be relevant to the process of learning from games, as well as to gain an understanding of positive and negative impressions about the game’s general content. The end results of the thematic analysis were measured up to the suggested ENED-GEM framework. Initial results generally support the main elements of the ENED-GEM, and future research into the importance of these individual core factors is outlined.

  16. ENED-GEM: A Conceptual Framework Model for Psychological Enjoyment Factors and Learning Mechanisms in Educational Games about the Environment.

    Science.gov (United States)

    Fjællingsdal, Kristoffer S; Klöckner, Christian A

    2017-01-01

    Based on a thorough review of psychological literature, this article seeks to develop a model of game enjoyment and environmental learning (ENvironmental EDucational Game Enjoyment Model, ENED-GEM) and delineate psychological processes that might facilitate learning and inspire behavioral change from educational games about the environment. A critically acclaimed digital educational game about environmental issues (Fate of the World by Red Redemption/Soothsayer Games) was used as a case study. Two hundred forty-nine reviews of the game from the popular gaming and reviewing platform known as Steam were analyzed by means of a thematic content analysis in order to identify key player enjoyment factors believed to be relevant to the process of learning from games, as well as to gain an understanding of positive and negative impressions about the game's general content. The end results of the thematic analysis were measured up to the suggested ENED-GEM framework. Initial results generally support the main elements of the ENED-GEM, and future research into the importance of these individual core factors is outlined.

  17. The GED4GEM project: development of a Global Exposure Database for the Global Earthquake Model initiative

    Science.gov (United States)

    Gamba, P.; Cavalca, D.; Jaiswal, K.S.; Huyck, C.; Crowley, H.

    2012-01-01

    In order to quantify earthquake risk of any selected region or a country of the world within the Global Earthquake Model (GEM) framework (www.globalquakemodel.org/), a systematic compilation of building inventory and population exposure is indispensable. Through the consortium of leading institutions and by engaging the domain-experts from multiple countries, the GED4GEM project has been working towards the development of a first comprehensive publicly available Global Exposure Database (GED). This geospatial exposure database will eventually facilitate global earthquake risk and loss estimation through GEM’s OpenQuake platform. This paper provides an overview of the GED concepts, aims, datasets, and inference methodology, as well as the current implementation scheme, status and way forward.

  18. A process-based evaluation of dust-emitting winds in the CMIP5 simulation of HadGEM2-ES

    Science.gov (United States)

    Fiedler, Stephanie; Knippertz, Peter; Woodward, Stephanie; Martin, Gill M.; Bellouin, Nicolas; Ross, Andrew N.; Heinold, Bernd; Schepanski, Kerstin; Birch, Cathryn E.; Tegen, Ina

    2016-02-01

    Despite the importance of dust aerosol in the Earth system, state-of-the-art models show a large variety for North African dust emission. This study presents a systematic evaluation of dust emitting-winds in 30 years of the historical model simulation with the UK Met Office Earth-system model HadGEM2-ES for the Coupled Model Intercomparison Project Phase 5. Isolating the effect of winds on dust emission and using an automated detection for nocturnal low-level jets (NLLJs) allow an in-depth evaluation of the model performance for dust emission from a meteorological perspective. The findings highlight that NLLJs are a key driver for dust emission in HadGEM2-ES in terms of occurrence frequency and strength. The annually and spatially averaged occurrence frequency of NLLJs is similar in HadGEM2-ES and ERA-Interim from the European Centre for Medium-Range Weather Forecasts. Compared to ERA-Interim, a stronger pressure ridge over northern Africa in winter and the southward displaced heat low in summer result in differences in location and strength of NLLJs. Particularly the larger geostrophic winds associated with the stronger ridge have a strengthening effect on NLLJs over parts of West Africa in winter. Stronger NLLJs in summer may rather result from an artificially increased mixing coefficient under stable stratification that is weaker in HadGEM2-ES. NLLJs in the Bodélé Depression are affected by stronger synoptic-scale pressure gradients in HadGEM2-ES. Wintertime geostrophic winds can even be so strong that the associated vertical wind shear prevents the formation of NLLJs. These results call for further model improvements in the synoptic-scale dynamics and the physical parametrization of the nocturnal stable boundary layer to better represent dust-emitting processes in the atmospheric model. The new approach could be used for identifying systematic behavior in other models with respect to meteorological processes for dust emission. This would help to improve dust

  19. Kombinierte Hoch-/Niedrig-Dosis-Therapie mit systemischen Glukokor-tikoiden bei schweren Verlaufsformen der Alopecia areata im Kindesalter.

    Science.gov (United States)

    Jahn-Bassler, Karin; Bauer, Wolfgang Michael; Karlhofer, Franz; Vossen, Matthias G; Stingl, Georg

    2017-01-01

    Schwere Verlaufsformen der Alopecia areata (AA) im Kindesalter sind aufgrund limitierter Optionen therapeutisch herausfordernd. Systemische, hochdosierte Glukokortikoide weisen die schnellste Ansprechrate auf, nach dem Absetzen kommt es allerdings zu Rezidiven. Eine längerfristige Hochdosis-Anwendung ist aufgrund der zu erwartenden Nebenwirkungen nicht empfehlenswert. Eine dauerhafte Steroiderhaltungstherapie unterhalb der Cushing-Schwellen-Dosis nach Bolustherapie könnte die Krankheitsaktivität ohne Nebenwirkungen längerfristig unterdrücken. Im Rahmen einer offenen Anwendungsbeobachtung wurden 13 Kinder mit schweren Formen der AA in diese Studie eingeschlossen. Bei sieben Kindern lag eine AA totalis/universalis vor, bei sechs eine multifokale AA mit Befall von mehr als 50 % der Kopfhaut. Das Therapieregime sah eine initiale Prednisolon-Dosierung von 2 mg/kg Körpergeweicht (KG) vor und wurde innerhalb von neun Wochen auf eine Erhaltungsdosierung unter der individuellen Cushing-Schwelle reduziert. Der Nachbeobachtungszeitraum betrug ein bis drei Jahre. Wir beobachteten in 62 % aller Fälle ein komplettes Nachwachsen der Haare. Die mittlere Dauer bis zum Ansprechen lag bei 6,6 Wochen und konnte mit der Erhaltungstherapie über den gesamten Beobachtungszeitraum aufrechterhalten werden. An Nebenwirkungen wurden ausschließlich eine Gewichtszunahme (1-3 kg) bei allen Behandelten sowie eine milde Steroidakne in 23 % der Fälle beobachtet. Die kombinierte Hoch-/Niedrig-Dosis-Therapie mit systemischen Glukokortikoiden mittels Prednisolon zeigte eine hohe, dauerhafte Ansprechrate ohne signifikante Nebenwirkungen. © 2017 Deutsche Dermatologische Gesellschaft (DDG). Published by John Wiley & Sons Ltd.

  20. Wie schneiden Sie ab?: Studie über Kontroll- und Prüfungsaktivitäten bei mittelgrossen Unternehmen, Spitälern und Hochschulen in der Schweiz

    OpenAIRE

    Ruud, T F; Isufi, S; Friebe, P; Stebler, W; Seheri, F; Emmenegger, M

    2008-01-01

    Kontroll- und Prüfungsaktivitäten unterstützen den Verwaltungsrat und die Geschäftsleitung bei der Steuerung und Kontrolle des Unternehmens. Bei mittelgrossen Unternehmen ist aufgrund der begrenzten personellen und finanziellen Ressourcen ein effektiver und effizienter Einsatz dieser Aktivitäten unerlässlich. Auch bei Spitälern und Hochschulen gewinnen Kontroll- und Prüfungsaktivitäten infolge erhöhter Wettbewerbsintensität und steigenden Kostendrucks sowie zunehmender Unabhängigkeit diese...

  1. Operational experience with the GEM detector assembly lines for the CMS forward muon upgrade

    CERN Document Server

    Vai, Ilaria

    2017-01-01

    The CMS Collaboration has been developing large-area Triple-GEM detectors to be installed in the muon endcap regions of the CMS experiment in 2019 to maintain forward muon trigger and tracking performance at the HL-LHC. Ten pre-production detectors were built at CERN to commission the first assembly line and the quality controls. These were installed in the CMS detector in early 2017 and are currently participating in the 2017 LHC run. The collaboration has prepared several additional assembly and quality control lines for distributed mass production of 160 GEM detectors at various sites worldwide. During 2017, these additional production sites have been optimizing construction techniques and quality control procedures and validating them against common specifications by constructing additional pre-production detectors. Using the specific experience from one production site as an example, we discuss how the quality controls make use of independent hardware and trained personnel to ensure fast and reliable pro...

  2. A 40 GByte/s read-out system for GEM

    International Nuclear Information System (INIS)

    Bowden, M.; Carrel, J.; Dorenbosch, J.; Kapoor, V.

    1994-04-01

    The preliminary design of the read-out system for the GEM (Gammas, Electrons, Muons) detector at the Superconducting Super Collider is presented. The system reads all digitized data from the detector data sources at a Level 1 trigger rate of up to 100 kHz. A total read-out bandwidth of 40 GBytes/s is available. Data are stored in buffers that are accessible for further event filtering by an on-line, processor farm. Data are transported to the farm only as they are needed by the higher-level trigger algorithms, leading to a reduced bandwidth requirement in the Data Acquisition System

  3. A micro-TCA based data acquisition system for the Triple-GEM detectors for the upgrade of the CMS forward muon spectrometer

    Science.gov (United States)

    Lenzi, T.

    2017-01-01

    The Gas Electron Multiplier (GEM) upgrade project aims at improving the performance of the muon spectrometer of the Compact Muon Solenoid (CMS) experiment which will suffer from the increase in luminosity of the Large Hadron Collider (LHC). The GEM collaboration proposes to instrument the first muon station with Triple-GEM detectors, a technology which has proven to be resistant to high fluxes of particles. The architecture of the readout system is based on the use of the microTCA standard hosting FPGA-based Advanced Mezzanine Card (AMC) and of the Versatile Link with the GBT chipset to link the on-detector electronics to the micro-TCA boards. For the front-end electronics a new ASIC, called VFAT3, is being developed. On the detector, a Xilinx Virtex-6 FPGA mezzanine board, called the OptoHybrid, has to collect the data from 24 VFAT3s and to transmit the data optically to the off-detector micro-TCA electronics, as well as to transmit the trigger data at 40 MHz to the CMS Cathode Strip Chamber (CSC) trigger. The microTCA electronics provides the interfaces from the detector (and front-end electronics) to the CMS DAQ, TTC (Timing, Trigger and Control) and Trigger systems. In this paper, we will describe the DAQ system of the Triple-GEM project and provide results from the latest test beam campaigns done at CERN.

  4. Summary of FY 1997 work related to JAPC-U.S. DOE contract study on improvement of core safety - study on GEM (III)

    International Nuclear Information System (INIS)

    Burke, T.M.

    1998-01-01

    FFTF was originally designed/constructed/operated to develop LMFBR fuels and materials. Inherent safety became a major focus of the US nuclear industry in the mid 1980's. The inherent safety characteristics of LMFBRs were recognized but additional enhancement was desired. The presentation contents are: Fast Flux Test Facility history and status; Overview of contract activities; Summary of loss of flow without scram with GEMs testing; and Summary of pump start with GEMs testing

  5. Aderência das Demonstrações Contábeis dos Fundos de Pensão do Brasil aos Padrões Contábeis Internacionais: Uma Análise Comparativa à Luz da IAS 26

    Directory of Open Access Journals (Sweden)

    Roswelton Anjos de Paula

    2014-08-01

    Full Text Available Apesar de o processo de convergência aos padrões internacionais provocar discussões nos vários ramos da Contabilidade, no Brasil os fundos de pensão devem observar um padrão contábil próprio, respeitando a independência patrimonial de todos os planos de benefícios dos fundos de pensão e identificando, separadamente, os planos previdenciais e assistenciais administrados pelas entidades fechadas de previdência complementar (EFPC. Com o intuito de verificar em que medida a elaboração das demonstrações contábeis das EFPC se encontra aderente aos padrões contábeis internacionais, foi efetuada uma análise comparativa entre os elementos que compõem as estruturas da Demonstração da Mutação do Ativo Líquido (DMAL, da Demonstração do Ativo Líquido (DAL e da Demonstração das Obrigações Atuariais do Plano de Benefícios (DOAP, definidas pelo padrão próprio brasileiro, e os elementos estabelecidos pela IAS 26 - Accounting and Reporting by Retirement Benefit Plans, que se aplica às demonstrações contábeis dos planos de benefícios, relatando e fornecendo informações aos participantes sobre os recursos e os benefícios do plano ao longo do tempo. Trata-se de um estudo de natureza exploratória, com abordagem qualitativa e coleta de dados realizada de forma essencialmente documental. A justificativa para o estudo está na percepção de que o desenvolvimento de um padrão próprio pode comprometer a inserção da Contabilidade dos fundos de pensão do Brasil nas melhores práticas internacionais, e inibir a participação de eventuais investidores na capitalização desses fundos. Os resultados mostram que as estruturas dos elementos que compõem as demonstrações contábeis desses fundos se encontram, em sua maior parte, aderentes ao disposto na IAS 26, sendo observadas, contudo, divergências de caráter formal nas estruturas das demonstrações contábeis e na mensuração a valor justo dos investimentos, pass

  6. Kyphoplasty and vertebroplasty for spinal trauma; Kyphoplastie und Vertebroplastie bei Wirbelsaeulentraumata

    Energy Technology Data Exchange (ETDEWEB)

    Ahlhelm, F. [Kantonsspital Baden AG, Abteilung fuer Neuroradiologie, Institut fuer Radiologie, Baden (Switzerland); Omidi, R. [Kantonsspital Baden AG, Interventionelle Radiologie, Institut fuer Radiologie, Baden (Switzerland)

    2016-08-15

    Minimally invasive treatment of spinal fractures. Conservative treatment versus spinal surgery. Minimally invasive stabilization techniques, such as percutaneous (assisted) cementoplasty have been introduced as new procedures. Magnetic resonance imaging (MRI), X-rays and computed tomography (CT) are the imaging techniques of first choice. The most important questions concern recent fractures, instability and indications for minimally invasive treatment. Vertebroplasty and kyphoplasty are established methods for the treatment of patients with osteoporosis. Cementoplasty techniques are promising treatment options for traumatic spinal injuries. The application of the techniques should best be carried out in individual cases within the framework of prospective controlled studies. (orig.) [German] Minimal-invasive Behandlung von Wirbelsaeulentraumata. Konservative Behandlung vs. Wirbelsaeulenchirurgie. Als neue Verfahren wurden minimal-invasive Stabilisationstechniken, z. B. perkutane (assistierte) Zementoplastien eingefuehrt. Roentgen, MRT und CT sind die bildgebenden Verfahren der ersten Wahl. Die wichtigsten Fragestellungen sind: Frische Fraktur? Instabilitaet? Indikation fuer minimal-invasive Behandlung ?Vertebroplastie und Kyphoplastie sind bei Osteoporosepatienten etabliert. Bei Wirbelsaeulentraumata sind Zementoplastietechniken vielversprechende Therapieoptionen. Die Anwendung der Techniken sollte im individuellen Fall am besten im Rahmen prospektiver kontrollierter Studien erfolgen. (orig.)

  7. 3MeerLICHT and BlackGEM: custom-built telescopes to detect faint optical transients

    NARCIS (Netherlands)

    Bloemen, S. (Steven); Groot, P.J. (Paul J.); Woudt, P. (Patrick); Wolt, M.K. (Marc Klein); Mcbride, V. (Vanessa); Nelemans, G. (Gijs); Körding, E. (Elmar); Pretorius, M.L. (Magaretha L.); Roelfsema, R. (Ronald); Bettonvil, F. (Felix); Balster, H. (Harry); Bakker, R. (Roy); Dolron, P. (Peter); Van Elteren, A. (Arjen); Elswijk, E. (Eddy); Engels, A. (Arno); R.P. Fender; Fokker, M. (Marc); Haan, M. (Menno De); Hagoort, K. (Klaas); De Hoog, J. (Jasper); Horst, R.T. (Rik Ter); Van Der Kevie, G. (Giel); Lowski, S.L.K. (Stanis Law Koz); Kragt, J. (Jan); Lech, G. (Grzegorz); Le Poole, R. (Rudolf); Lesman, D. (Dirk); J. Morren (Johan); Navarro, R. (Ramon); Paalberends, W.-J. (Willem-Jelle); K.G. Paterson (Kerry); Laszek, R.P. (Rafal Paw); Pessemier, W. (Wim); Raskin, G. (Gert); Rutten, H. (Harrie); L.H.A. Scheers (Bart); Schuil, M. (Menno); Sybilski, P.W. (Piotr W.)

    2016-01-01

    textabstractWe present the MeerLICHT and BlackGEM telescopes, which are wide-field optical telescopes that are currently being built to study transient phenomena, gravitational wave counterparts and variable stars. The telescopes have 65 cm primary mirrors and a 2.7 square degree field-of-view. The

  8. Guidelines on {sup 99m}Tc-DMSA scintigraphy in children; Empfehlungen zur Durchfuehrung der DMSA-Szintigraphie bei Kindern

    Energy Technology Data Exchange (ETDEWEB)

    Piepsz, A. [CHU St. Pierre, Bruessel (Belgium); Colarinha, P. [Instituto Portugues de Oncologia, Lissabon (Portugal); Gordon, I. [Great Ormend Street Hospital for Children, London (United Kingdom); Hahn, K. [Muenchen Univ. (Germany). Klinik fuer Nuklearmedizin; Olivier, P. [CHU Vandoeuvre, Nancy (France); Roca, I.; Velzen, J. van [Hospital Vall d' Hebron, Barcelona (Spain); Sixt, R. [The Queen Silvia Children' s Hospital, Goeteborg (Sweden)

    2000-11-01

    The guidelines are intended to help nuclear medical teams in their daily routine. The guidelines give information relating to indications, imaging parameters, data evaluation and interpretation. The guidelines are in line with the opinions of the Paediatric Committee of EANM and hence focus on approaches adopted in Europe, e.g. as regards selection of the radiopharmaceuticals or activity levels applied. The guidelines should be seen in the context of local quality standards and regulatory requirements. (orig./CB) [German] Zweck dieser Empfehlung ist es, dem Nuklearmedizinischen Team bei Tc-DMSA-Szintigraphie von Kindern Hilfestellung fuer die taegliche Routinepraxis zu geben. Die Empfehlung enthaelt Informationen ueber Indikationen, Aufnahmeparameter, Auswertung und Interpretation der DMSA-Szintigraphie bei Kindern. Die vorliegende Empfehlung fasst die Meinung des Paediatric Committee der EANM zusammen und ist daher mehr auf die Europaeische Vorgehensweise, z.B. bei der Wahl des Radiopharmazeutikums und den verwendeten Aktivitaetsmengen, ausgerichtet. Sie sollte immer in Zusammenhang mit lokalen Qualitaetsstandards und Vorschriften gesehen werden. (orig.)

  9. Comparison of the HadGEM2 climate-chemistry model against in situ and SCIAMACHY atmospheric methane data

    Directory of Open Access Journals (Sweden)

    G. D. Hayman

    2014-12-01

    Full Text Available Wetlands are a major emission source of methane (CH4 globally. In this study, we evaluate wetland emission estimates derived using the UK community land surface model (JULES, the Joint UK Land Earth Simulator against atmospheric observations of methane, including, for the first time, total methane columns derived from the SCIAMACHY instrument on board the ENVISAT satellite. Two JULES wetland emission estimates are investigated: (a from an offline run driven with Climatic Research Unit–National Centers for Environmental Prediction (CRU-NCEP meteorological data and (b from the same offline run in which the modelled wetland fractions are replaced with those derived from the Global Inundation Extent from Multi-Satellites (GIEMS remote sensing product. The mean annual emission assumed for each inventory (181 Tg CH4 per annum over the period 1999–2007 is in line with other recently published estimates. There are regional differences as the unconstrained JULES inventory gives significantly higher emissions in the Amazon (by ~36 Tg CH4 yr−1 and lower emissions in other regions (by up to 10 Tg CH4 yr−1 compared to the JULES estimates constrained with the GIEMS product. Using the UK Hadley Centre's Earth System model with atmospheric chemistry (HadGEM2, we evaluate these JULES wetland emissions against atmospheric observations of methane. We obtain improved agreement with the surface concentration measurements, especially at high northern latitudes, compared to previous HadGEM2 runs using the wetland emission data set of Fung et al. (1991. Although the modelled monthly atmospheric methane columns reproduce the large-scale patterns in the SCIAMACHY observations, they are biased low by 50 part per billion by volume (ppb. Replacing the HadGEM2 modelled concentrations above 300 hPa with HALOE–ACE assimilated TOMCAT output results in a significantly better agreement with the SCIAMACHY observations. The use of the GIEMS product to constrain the JULES

  10. gem-Difluoroolefination of Diazo Compounds with TMSCF3 or TMSCF2Br: Transition-Metal-Free Cross-Coupling of Two Carbene Precursors.

    Science.gov (United States)

    Hu, Mingyou; Ni, Chuanfa; Li, Lingchun; Han, Yongxin; Hu, Jinbo

    2015-11-18

    A new olefination protocol for transition-metal-free cross-coupling of two carbene fragments arising from two different sources, namely, a nonfluorinated carbene fragment resulting from a diazo compound and a difluorocarbene fragment derived from Ruppert-Prakash reagent (TMSCF3) or TMSCF2Br, has been developed. This gem-difluoroolefination proceeds through the direct nucleophilic addition of diazo compounds to difluorocarbene followed by elimination of N2. Compared to previously reported Cu-catalyzed gem-difluoroolefination of diazo compounds with TMSCF3, which possesses a narrow substrate scope due to a demanding requirement on the reactivity of diazo compounds and in-situ-generated CuCF3, this transition-metal-free protocol affords a general and efficient approach to various disubstituted 1,1-difluoroalkenes, including difluoroacrylates, diaryldifluoroolefins, as well as arylalkyldifluoroolefins. In view of the ready availability of diazo compounds and difluorocarbene reagents and versatile transformations of 1,1-difluoroalkenes, this new gem-difluoroolefination method is expected to find wide applications in organic synthesis.

  11. Study on the novel neutron-to-proton convertor for improving the detection efficiency of a triple GEM based fast neutron detector

    International Nuclear Information System (INIS)

    Wang Xiaodong; Yang Lei; Zhang Chunhui; Hu Bitao; Yang Herun; Zhang Junwei; Ren Zhongguo; Ha Ri-Ba-La; An Luxing

    2015-01-01

    A high-efficiency fast neutron detector prototype based on a triple Gas Electron Multiplier (GEM) detector, which, coupled with a novel multi-layered high-density polyethylene (HDPE) as a neutron-to-proton converter for improving the neutron detection efficiency, is introduced and tested with the Am-Be neutron source in the Institute of Modern Physics (IMP) at Lanzhou in the present work. First, the developed triple GEM detector is tested by measuring its effective gain and energy resolution with "5"5Fe X-ray source to ensure that it has a good performance. The effective gain and obtained energy resolution is 5.0 × 10"4 and around 19.2%, respectively. Secondly, the novel multi-layered HDPE converter is coupled with the cathode of the triple GEM detector making it a high-efficiency fast neutron detector. Its effective neutron response is four times higher than that of the traditional single-layered conversion technique when the converter layer number is 38. (authors)

  12. Tomographic capabilities of the new GEM based SXR diagnostic of WEST

    Czech Academy of Sciences Publication Activity Database

    Jardin, A.; Mazon, D.; O’Mullane, M.; Mlynář, Jan; Löffelmann, Viktor; Imríšek, Martin; Chernyshova, M.; Czarski, T.; Kasprowicz, G.; Wojenski, A.; Bourdelle, C.; Malard, P.

    2016-01-01

    Roč. 11, July (2016), č. článku C07006. ISSN 1748-0221. [International Conference Frontiers in Diagnostics fix Technologies (ICFDT4). Frascati (Rome), 30.03.2016-01.04.2016] Institutional support: RVO:61389021 Keywords : GEM * SXR * tomography * plasma diagnostics Subject RIV: BL - Plasma and Gas Discharge Physics OBOR OECD: 2.11 Other engineering and technologies Impact factor: 1.220, year: 2016 http://iopscience.iop.org/article/10.1088/1748-0221/11/07/C07006/pdf

  13. Diagnostik der Fatigue bei Multipler Sklerose [Assessment of fatigue in multiple sclerosis

    NARCIS (Netherlands)

    Sander, C.; Voelter, H.U.; Schlake, H.P.; Eling, P.A.T.M.; Hildebrandt, H.

    2017-01-01

    Hintergrund: Fatigue ist eines der häufigsten Symptome bei Multipler Sklerose (MS) und hat deutliche Auswirkungen auf die Lebensqualität sowie die Berufstätigkeit. Die adäquate Messung der erlebten Fatigue ist aber auch heutzutage noch mit erheblicher Unsicherheit behaftet. Ziel der Arbeit: In dem

  14. A study of the effect of non-spherical dust particles on Geostationary Environment Monitoring Spectrometer (GEMS) aerosol optical properties retrievals

    Science.gov (United States)

    Go, S.; Kim, J.; KIM, M.; Choi, M.; Lim, H.

    2017-12-01

    Non-spherical assumption of particle shape has been used to replace the spherical assumption in the Geostationary Environment Monitoring Spectrometer (GEMS) aerosol optical properties retrievals for dust particles. GEMS aerosol retrieval algorithms are based on optimal estimation method to provide aerosol optical depth (AOD), single scattering albedo (SSA) at 443nm, and aerosol loading height (ALH) simultaneously as products. Considering computing time efficiency, the algorithm takes Look-Up Table (LUT) approach using Vector Linearized Discrete Ordinate Radiative Transfer code (VLIDORT), and aerosol optical properties for three aerosol types of absorbing fine aerosol (BC), dust and non-absorbing aerosol (NA) are integrated from AERONET inversion data, and fed into the LUT calculation. In this study, by applying the present algorithm to OMI top-of the atmosphere normalized radiance, retrieved AOD, SSA with both spherical and non-spherical assumptions have been compared to the surface AERONET observations at East Asia sites for 3 years from 2005 to 2007 to evaluate and quantify the effect of non-spherical dust particles on the satellite aerosol retrievals. The root-mean-square error (RMSE) in the satellite retrieved AOD have been slightly reduced as a result of adopting the non-spherical assumption in the GEMS aerosol retrieval algorithm. For SSA, algorithm tested with spheroid models on dust particle shows promising results for the improved SSA. In terms of ALH, the results are qualitatively compared with CALIOP products, and shows consistent variation. This result suggests the importance of taking into account the effects of non-sphericity in the retrieval of dust particles from GEMS measurements.

  15. CSC large panel R ampersand D summary for the SSC GEM muon subsystem

    International Nuclear Information System (INIS)

    Pratuch, S.M.; Clements, J.W.; Spellman, G.P.

    1994-05-01

    The GEM Detector uses 1,128 Cathode Strip Chamber (CSC) muon detectors requiring a total of approximately 10,000 precision panels in the CSC assemblies. These panels must be fabricated to extreme tolerances in order to meet the physics requirement. A fabrication technique used to produce two large panels, nominally 1 by 3 meters, is described and the resulting panel precision is reported

  16. Gems [Guardian Environmental Monitoring System] keeps a continuous eye on gamma-ray emissions

    International Nuclear Information System (INIS)

    Gould, J.L.

    1986-01-01

    To enable electricity utilities to demonstrate the very low release rates of radiation emitters from nuclear power stations into the environment, Gems (Guardian Environmental Monitoring System) has been developed. The units have been installed as emergency plume monitors round the perimeter of several British power stations and can be connected to windspeed and direction instrumentation to provide on-line activity release data. (UK)

  17. Operation of a GEM-TPC with pixel readout

    CERN Document Server

    Brezina, C; Kaminski, J; Killenberg, M; Krautscheid, T

    2012-01-01

    A prototype time projection chamber with 26 cm drift length was operated with a short-spaced triple gas electron multiplier (GEM) stack in a setup triggering on cosmic muon tracks. A small part of the anode plane is read out with a CMOS pixel application-specified integrated circuit (ASIC) named Timepix, which provides ultimate readout granularity. Pixel clusters of charge depositions corresponding to single primary electrons are observed and analyzed to reconstruct charged particle tracks. A dataset of several weeks of cosmic ray data is analyzed. The number of clusters per track length is well described by simulation. The obtained single point resolution approaches 50 m at short drift distances and is well reproduced by a simple model of single-electron diffusion.

  18. Empirical CPU power modelling and estimation in the gem5 simulator

    OpenAIRE

    Basireddy, Karunakar Reddy; Walker, Matthew; Balsamo, Domenico; Diestelhorst, Stephan; Al-Hashimi, Bashir; Merrett, Geoffrey

    2017-01-01

    Power modelling is important for modern CPUs to inform power management approaches and allow design space exploration. Power simulators, combined with a full-system architectural simulator such as gem5, enable power-performance trade-offs to be investigated early in the design of a system with different configurations (e.g number of cores, cache size, etc.). However, the accuracy of existing power simulators, such as McPAT, is known to be low due to the abstraction and specification errors, a...

  19. Verlauf der zellulären Immunantwort bei Lebendnierenempfängern - Messung von IFN-γ und IL-17 im Elispot-Assay

    OpenAIRE

    Grehn, Conrad

    2015-01-01

    Die Nierentransplantation ermöglicht Patienten die Wiederherstellung der Nierenfunktion. Aufgrund der begrenzten Verfügbarkeit an Organen nimmt dabei die Zahl der Transplantationen von einem lebenden Spender stetig zu. Zudem ermöglichen die präzisen und genauen Vorbereitungen und Abläufe bei Lebendnierenspenden eine bessere 5-Jahres-Überlebensrate als bei Kadaverspenden. Die genetische Verschiedenheit zwischen Spender und Empfänger bedingt jedoch eine lebenslange immunsuppressive Therapie, um...

  20. The gem collection of the Rijksmuseum van Geologie en Mineralogie of Leiden The Peridots

    NARCIS (Netherlands)

    Zwaan, P.C.

    1957-01-01

    The peridots in the gem collection of our Museum were acquired a long time ago (part of them were from the collection of King William I of the Netherlands). We should be sceptical about data on the origin of this material. Firstly we do not generally know whether the stones were bought or received

  1. Sensitivity analysis of the GEMS soil organic carbon model to land cover land use classification uncertainties under different climate scenarios in Senegal

    Science.gov (United States)

    Dieye, A.M.; Roy, David P.; Hanan, N.P.; Liu, S.; Hansen, M.; Toure, A.

    2012-01-01

    Spatially explicit land cover land use (LCLU) change information is needed to drive biogeochemical models that simulate soil organic carbon (SOC) dynamics. Such information is increasingly being mapped using remotely sensed satellite data with classification schemes and uncertainties constrained by the sensing system, classification algorithms and land cover schemes. In this study, automated LCLU classification of multi-temporal Landsat satellite data were used to assess the sensitivity of SOC modeled by the Global Ensemble Biogeochemical Modeling System (GEMS). The GEMS was run for an area of 1560 km2 in Senegal under three climate change scenarios with LCLU maps generated using different Landsat classification approaches. This research provides a method to estimate the variability of SOC, specifically the SOC uncertainty due to satellite classification errors, which we show is dependent not only on the LCLU classification errors but also on where the LCLU classes occur relative to the other GEMS model inputs.

  2. Imaging of high-Z material for nuclear contraband detection with a minimal prototype of a muon tomography station based on GEM detectors

    Energy Technology Data Exchange (ETDEWEB)

    Gnanvo, Kondo, E-mail: kgnanvo@fit.edu [Department of Physics and Space Sciences, Florida Institute of Technology, Melbourne, FL 32901 (United States); Grasso, Leonard V.; Hohlmann, Marcus; Locke, Judson B.; Quintero, Amilkar [Department of Physics and Space Sciences, Florida Institute of Technology, Melbourne, FL 32901 (United States); Mitra, Debasis [Department of Computer Sciences, Florida Institute of Technology, Melbourne, FL 32901 (United States)

    2011-10-01

    Muon Tomography based on the measurement of multiple scattering of atmospheric cosmic ray muons in matter is a promising technique for detecting heavily shielded high-Z radioactive materials (U, Pu) in cargo or vehicles. The technique uses the deflection of cosmic ray muons in matter to perform tomographic imaging of high-Z material inside a probed volume. A Muon Tomography Station (MTS) requires position-sensitive detectors with high spatial resolution for optimal tracking of incoming and outgoing cosmic ray muons. Micro Pattern Gaseous Detector (MPGD) technologies such as Gas Electron Multiplier (GEM) detectors are excellent candidates for this application. We have built and operated a minimal MTS prototype based on 30 cmx30 cm GEM detectors for probing targets with various Z values inside the MTS volume. We report the first successful detection and imaging of medium-Z and high-Z targets of small volumes ({approx}0.03 L) using GEM-based Muon Tomography.

  3. Imaging of high-Z material for nuclear contraband detection with a minimal prototype of a muon tomography station based on GEM detectors

    International Nuclear Information System (INIS)

    Gnanvo, Kondo; Grasso, Leonard V.; Hohlmann, Marcus; Locke, Judson B.; Quintero, Amilkar; Mitra, Debasis

    2011-01-01

    Muon Tomography based on the measurement of multiple scattering of atmospheric cosmic ray muons in matter is a promising technique for detecting heavily shielded high-Z radioactive materials (U, Pu) in cargo or vehicles. The technique uses the deflection of cosmic ray muons in matter to perform tomographic imaging of high-Z material inside a probed volume. A Muon Tomography Station (MTS) requires position-sensitive detectors with high spatial resolution for optimal tracking of incoming and outgoing cosmic ray muons. Micro Pattern Gaseous Detector (MPGD) technologies such as Gas Electron Multiplier (GEM) detectors are excellent candidates for this application. We have built and operated a minimal MTS prototype based on 30 cmx30 cm GEM detectors for probing targets with various Z values inside the MTS volume. We report the first successful detection and imaging of medium-Z and high-Z targets of small volumes (∼0.03 L) using GEM-based Muon Tomography.

  4. Trace elemental analysis of Indian natural moonstone gems by PIXE and XRD techniques.

    Science.gov (United States)

    Venkateswara Rao, R; Venkateswarulu, P; Kasipathi, C; Sivajyothi, S

    2013-12-01

    A selected number of Indian Eastern Ghats natural moonstone gems were studied with a powerful nuclear analytical and non-destructive Proton Induced X-ray Emission (PIXE) technique. Thirteen elements, including V, Co, Ni, Zn, Ga, Ba and Pb, were identified in these moonstones and may be useful in interpreting the various geochemical conditions and the probable cause of their inceptions in the moonstone gemstone matrix. Furthermore, preliminary XRD studies of different moonstone patterns were performed. The PIXE technique is a powerful method for quickly determining the elemental concentration of a substance. A 3MeV proton beam was employed to excite the samples. The chemical constituents of moonstones from parts of the Eastern Ghats geological formations of Andhra Pradesh, India were determined, and gemological studies were performed on those gems. The crystal structure and the lattice parameters of the moonstones were estimated using X-Ray Diffraction studies, trace and minor elements were determined using the PIXE technique, and major compositional elements were confirmed by XRD. In the present work, the usefulness and versatility of the PIXE technique for research in geo-scientific methodology is established. © 2013 Elsevier Ltd. All rights reserved.

  5. White matter alterations in neurodegenerative and vascular dementia; Marklagerveraenderungen bei neurodegenerativen und vaskulaeren Demenzerkrankungen

    Energy Technology Data Exchange (ETDEWEB)

    Supprian, T. [Arbeitsgruppe Gerontopsychiatrie, Universitaets-Nervenklinik Homburg (Germany); Arbeitsgruppe Gerontopsychiatrie, Universitaets-Nervenklinik, Psychiatrie und Psychotherapie, 66421, Homburg (Germany); Kessler, H.; Falkai, P. [Arbeitsgruppe Gerontopsychiatrie, Universitaets-Nervenklinik Homburg (Germany); Retz, W.; Roesler, M. [Arbeitsgruppe Gerontopsychiatrie, Universitaets-Nervenklinik Homburg (Germany); Institut fuer gerichtliche Psychologie und Psychiatrie, Universitaet des Saarlandes, Homburg (Germany); Grunwald, I.; Reith, W. [Abteilung fuer Neuroradiologie, Universitaetskliniken des Saarlandes, Homburg (Germany)

    2003-07-01

    Due to a significant overlap of the two syndromes, differentiation of degenerative dementia of the Alzheimer-type from vascular dementia may be difficult even when imaging studies are available. White matter changes occur in many patients suffering from Alzheimer's disease. Little is known about the impact of white matter changes on the course and clinical presentation of Alzheimer's disease. High sensitivity of MRI in the detection of white matter alterations may account for over-diagnosing vascular dementia. The clinical significance of white matter alterations in dementia is still a matter of debate. The article reviews current concepts about the role of white matter alterations in dementia. (orig.) [German] Die Zuordnung einer Demenzerkrankung zu einem neurodegenerativen Pathomechanismus, wie der Demenz vom Alzheimer-Typ (DAT) oder einem vaskulaeren Pathomechanismus, kann trotz der Verfuegbarkeit bildgebender Verfahren Probleme bereiten. Ueberlappungen neurodegenerativer und vaskulaerer Mechanismen sind haeufig. Mikroangiopathische Veraenderungen des Marklagers finden sich bei einem hohen Anteil von Patienten mit der klinischen Verlaufsform einer Demenz vom Alzheimer-Typ. Es ist unklar, ob es sich um eine Koinzidenz zweier Pathomechanismen handelt oder ob eine wechselseitige Beeinflussung stattfindet. Die hohe Sensitivitaet der Magnetresonanztomographie bei der Erfassung mikroangiopathischer Veraenderungen des Marklagers koennte dazu fuehren, dass zu vaskulaere Demenzerkrankungen haeufig diagnostiziert werden. Der Einfluss mikroangiopathischer Veraenderungen des Marklagers auf den Demenzverlauf wird kontrovers diskutiert. Die vorgelegte Arbeit gibt eine Uebersicht ueber die aktuellen Konzepte zum Stellenwert von Marklagerveraenderungen bei Demenzerkrankungen. (orig.)

  6. Therapeutische Überlegungen bei sensomotorischer diabetischer Neuropathie

    Directory of Open Access Journals (Sweden)

    Bührlen M

    2013-01-01

    Full Text Available Der Begriff der sensomotorischen diabetischen Neuropathie beschreibt einen heterogenen Beschwerdekomplex, der auf einer diabetesbedingten Schädigung des peripheren Nervensystems beruht. Bis zu 50 % der Menschen mit Diabetes mellitus leiden im Verlauf ihrer Erkrankung an Symptomen einer sensomotorischen Neuropathie. Chronische Schmerzen, Dysund Parästhesien sowie die Komplikation des diabetischen Fußsyndroms stellen für die Betroffenen gravierende Folgen dar. Die Optimierung der metabolischen Kontrolle stellt eine wichtige Basismaßnahme dar. Andere, zweifelsfrei gesicherte Möglichkeiten der Prävention oder kausalen Therapie sind nicht bekannt. Bei Auftreten einer schmerzhaften Neuropathie sollte eine gezielte analgetische Therapie möglichst früh begonnen werden. Mit den trizyklischen Antidepressiva, Duloxetin, Gabapentin und Pregabalin stehen Wirkstoffe zur Verfügung, die eine spezifische Therapie neuropathischer Schmerzen ermöglichen. Dabei ist zu beachten, dass in der Regel keine Schmerzfreiheit erreicht werden kann. Entscheidend ist das Erreichen eines für den Patienten tolerablen Schmerzniveaus unter Minimierung medikamentenassoziierter Nebenwirkungen. Das individuelle Ansprechen auf ein Medikament und die optimale Dosis können nicht vorhergesagt, sondern müssen individuell erprobt werden. Bei leichten Schmerzen können die Nicht-Opioid- Analgetika Paracetamol und Metamizol eingesetzt werden. Fehlen Therapiealternativen, dann stellen Opioide eine weitere Möglichkeit der Therapie starker Schmerzen dar. Aufgrund einer zusätzlichen Monoamin-Wiederaufnahmehemmerwirkung nehmen Tramadol und Tapentadol in dieser Gruppe eine Sonderstellung ein. In der Risiko- Nutzen-Abwägung darf das Nebenwirkungs- und Abhängigkeitspotenzial der Opioide in der Langzeittherapie nicht unterschätzt werden. Für andere medikamentöse Therapien oder alternative Therapiemethoden liegt keine ausreichende wissenschaftliche Evidenz vor. Sie können aber im

  7. Taxonomia de distorções contábeis

    OpenAIRE

    José Humberto da Cruz Cunha; Rogério Henrique de Araújo Júnior

    2017-01-01

    http://dx.doi.org/10.5007/1518-2924.2017v22n49p127 Discute o uso de uma taxonomia de distorções contábeis provenientes de erros e fraudes, voltada para o uso dos auditores na análise dos riscos e escolha dos procedimentos de auditoria. Sua elaboração segue as orientações conceituais da classificação facetada, por meio de levantamento conceitual em pesquisa bibliográfica. A taxonomia apresentada possui como categorias fundamentais as fases da informação, aspectos essenciais, afirmações, ci...

  8. Diagnostic evaluatuin of gastrointestinal tumors; Diagnostik bei Tumoren im Gastrointestinaltrakt

    Energy Technology Data Exchange (ETDEWEB)

    Linke, R.; Tatsch, K. [Ludwig-Maximilians-Univ. Muenchen (Germany). Klinik und Poliklinik fuer Nuklearmedizin

    1998-07-01

    difficult to distinguish between chronic pancreatitis and pancreatic carcinoma. In such cases a PET scan may be helpful. For planning of surgery and for preoperative staging morphological imaging is essential, but in nearly 40% of the patients nonresectable tumors were detected intraoperatively, which were not diagnosed by preoperative CT or MRI. PET seems to be more accurate in this respect, too. (orig.) [Deutsch] Hauptaufgaben der radiologischen und nuklearmedizinischen Diagnostik bei gastrointestinalen Tumoren sind Diagnosesicherung sowie praeoperatives Staging. Die Hohlorgane des oberen und unteren GI-Traktes (Oesophagus, Magen, Duodenum, Kolon, Rektum) werden primaer endoskopisch und endosonographisch abgeklaert. CT oder MRT liefern Informationen ueber Ausdehnung des Tumors, eine Infiltration in umgebende Strukturen und das Vorliegen pathologischer Lymphknoten. Das sensitivste Verfahren zum Nachweis von Lymphknoten- oder Fernmetastasen ist die PET. Auch die Differenzierung eines Lokalrezidivs von postoperativer Narbenbildung, z.B. beim kolorektalen Karzinom, gelingt mit der PET fruehzeitiger als mit den konventionellen morphologischen Verfahren. Lebertumoren sollten primaer sonographisch und bei fraglicher Dignitaet anschliessend mittels MRT untersucht werden. In der Differentialdiagnostik von unklaren Leberherden ist die nuklearmedizinische Rezeptorszintigraphie wegweisend. Benigne Leberlaesionen koennen mit der Neogalaktoalbumin-(NGA-)Szintigraphie sicher von malignen Tumoren (Metastasen, hepatozellulaeres Karzinom [HCC]) abgegrenzt werden, da NGA-Rezeptoren nur auf funktionstuechtigen Hepatozyten experimentiert werden. Die Unterscheidung von Lebermetastasen und dem HCC gelingt mit der Insulinszintigraphie, da sich Insulin aufgrund einer Ueberexpression von Insulinrezeptoren mit HCC vermehrt anreichert. Ergeben die vorgeschalteten Untersuchungen den Verdacht auf einen malignen Prozess, sollte zusaetzlich eine CT-Arterioportographie durchgefuehrt werden, da dieses

  9. CtGEM typing: Discrimination of Chlamydia trachomatis ocular and urogenital strains and major evolutionary lineages by high resolution melting analysis of two amplified DNA fragments.

    Science.gov (United States)

    Giffard, Philip M; Andersson, Patiyan; Wilson, Judith; Buckley, Cameron; Lilliebridge, Rachael; Harris, Tegan M; Kleinecke, Mariana; O'Grady, Kerry-Ann F; Huston, Wilhelmina M; Lambert, Stephen B; Whiley, David M; Holt, Deborah C

    2018-01-01

    Chlamydia trachomatis infects the urogenital tract (UGT) and eyes. Anatomical tropism is correlated with variation in the major outer membrane protein encoded by ompA. Strains possessing the ocular ompA variants A, B, Ba and C are typically found within the phylogenetically coherent "classical ocular lineage". However, variants B, Ba and C have also been found within three distinct strains in Australia, all associated with ocular disease in children and outside the classical ocular lineage. CtGEM genotyping is a method for detecting and discriminating ocular strains and also the major phylogenetic lineages. The rationale was facilitation of surveillance to inform responses to C. trachomatis detection in UGT specimens from young children. CtGEM typing is based on high resolution melting analysis (HRMA) of two PCR amplified fragments with high combinatorial resolving power, as defined by computerised comparison of 65 whole genomes. One fragment is from the hypothetical gene defined by Jali-1891 in the C. trachomatis B_Jali20 genome, while the other is from ompA. Twenty combinatorial CtGEM types have been shown to exist, and these encompass unique genotypes for all known ocular strains, and also delineate the TI and T2 major phylogenetic lineages, identify LGV strains and provide additional resolution beyond this. CtGEM typing and Sanger sequencing were compared with 42 C. trachomatis positive clinical specimens, and there were no disjunctions. CtGEM typing is a highly efficient method designed and tested using large scale comparative genomics. It divides C. trachomatis into clinically and biologically meaningful groups, and may have broad application in surveillance.

  10. Studies of aging and HV break down problems during development and operation of MSGC and GEM detectors for the inner tracking system of HERA-B

    International Nuclear Information System (INIS)

    Bagaturia, Y.; Baruth, O.; Dreis, H.B.; Eisele, F.; Gorbunov, I.; Gradl, S.; Gradl, W.; Hausmann, S.; Hildebrandt, M.; Hott, T.; Keller, S.; Krauss, C.; Lomonosov, B.; Negodaev, M.; Richter, C.; Robmann, P.; Schmidt, B.; Straumann, U.; Truoel, P.; Visbeck, S.; Walter, T.; Werner, C.; Werthenbach, U.; Zech, G.; Zeuner, T.; Ziegler, M.

    2002-01-01

    The results of 5 years of development of the inner tracking system of the HERA-B experiment and first experience from the data taking period of the year 2000 are reported. The system contains 184 chambers, covering a sensitive area of about (20x20) cm 2 each. The detector is based on microstrip gas counters (MSGCs) with diamond-like coated (DLC) glass wafers and gas electron multipliers (GEMs). The main problems in the development phase were gas discharges in intense hadron beams and aging in a high radiation dose environment. The observation of gas discharges which damage the electrode structure of the MSGC led to the addition of the GEM as a first amplification step. Spurious sparking at the GEM cannot be avoided completely. It does not affect the GEM itself but can produce secondary damage of the MSGC if the electric field between the GEM and the MSGC is above a threshold depending on the operation conditions. We observed that aging does not only depend on the dose but also on the spot size of the irradiated area. Ar-DME mixtures had to be abandoned whereas a mixture of 70% Ar and 30% CO 2 showed no serious aging effects up to about 40 mC/cm deposited charge on the anodes. X-ray measurements indicate that the DLC of the MSGC is deteriorated by the gas amplification process. As a consequence, long-term gain variations are expected. The Inner Tracker has successfully participated in the data taking at HERA-B during summer 2000

  11. Studies of aging and HV break down problems during development and operation of MSGC and GEM detectors for the inner tracking system of HERA-B

    Energy Technology Data Exchange (ETDEWEB)

    Bagaturia, Y.; Baruth, O.; Dreis, H.B.; Eisele, F.; Gorbunov, I.; Gradl, S.; Gradl, W.; Hausmann, S.; Hildebrandt, M.; Hott, T.; Keller, S.; Krauss, C.; Lomonosov, B.; Negodaev, M.; Richter, C.; Robmann, P.; Schmidt, B.; Straumann, U.; Truoel, P.; Visbeck, S.; Walter, T.; Werner, C.; Werthenbach, U.; Zech, G. E-mail: zech@physik.uni-siegen.de; Zeuner, T.; Ziegler, M

    2002-09-01

    The results of 5 years of development of the inner tracking system of the HERA-B experiment and first experience from the data taking period of the year 2000 are reported. The system contains 184 chambers, covering a sensitive area of about (20x20) cm{sup 2} each. The detector is based on microstrip gas counters (MSGCs) with diamond-like coated (DLC) glass wafers and gas electron multipliers (GEMs). The main problems in the development phase were gas discharges in intense hadron beams and aging in a high radiation dose environment. The observation of gas discharges which damage the electrode structure of the MSGC led to the addition of the GEM as a first amplification step. Spurious sparking at the GEM cannot be avoided completely. It does not affect the GEM itself but can produce secondary damage of the MSGC if the electric field between the GEM and the MSGC is above a threshold depending on the operation conditions. We observed that aging does not only depend on the dose but also on the spot size of the irradiated area. Ar-DME mixtures had to be abandoned whereas a mixture of 70% Ar and 30% CO{sub 2} showed no serious aging effects up to about 40 mC/cm deposited charge on the anodes. X-ray measurements indicate that the DLC of the MSGC is deteriorated by the gas amplification process. As a consequence, long-term gain variations are expected. The Inner Tracker has successfully participated in the data taking at HERA-B during summer 2000.

  12. A micro-TCA based data acquisition system for the Triple-GEM detectors for the upgrade of the CMS forward muon spectrometer

    CERN Document Server

    Lenzi, Thomas

    2016-01-01

    We will present the electronic and DAQ system being developed for TripleGEM detectors which will be installed in the CMS muon spectrometer. The microTCA system uses an Advanced Mezzanine Card equipped with an FPGA and the Versatile Link with the GBT chipset to link the front and back-end. On the detector an FPGA mezzanine board, the OptoHybrid, has to collect the data from the detector readout chips to transmit them optically to the microTCA boards using the GBT protocol. We will describe the hardware architecture, report on the status of the developments, and present results obtained with the system.In this contribution we will report on the progress of the design of the electronic readout and data acquisition (DAQ) system being developed for Triple-GEM detectors which will be installed in the forward region (1.5 < eta < 2.2) of the CMS muon spectrometer during the 2nd long shutdown of the LHC, planed for the period 2018-2019. The architecture of the Triple-GEM readout system is based on the use of the...

  13. Use of Excel ion exchange equilibrium solver with WinGEMS to model and predict NPE distribution in the Mead/Westvaco Evandale, TX, hardwood bleach plant

    Science.gov (United States)

    Christopher Litvay; Alan Rudie; Peter Hart

    2003-01-01

    An Excel spreadsheet developed to solve the ion-exchange equilibrium in wood pulps has been linked by dynamic data exchange to WinGEMS and used to model the non-process elements in the hardwood bleach plant of the Mead/Westvaco Evandale mill. Pulp and filtrate samples were collected from the diffusion washers and final wash press of the bleach plant. A WinGEMS model of...

  14. An Entrepreneurial Well-being Model based on GEM Data for Spain

    Directory of Open Access Journals (Sweden)

    José Manuel Sáiz-Álvarez

    2014-03-01

    Full Text Available The Economics of Happiness is one of the research areas of greatest growth in recent years. Throughout this work, a venture based model in which satisfaction of Spanish entrepreneurs with their professional life is performed. We analyze the responses of 9,989 entrepreneurs using data from the Global Entrepreneurship Monitor (GEM, and six hypothesis are discussed. The results show that, for the Spanish case, there is a strong consistency in the results the opportunity entrepreneurs present greater satisfaction than necessity entrepreneurs.

  15. A Continuously Running High-Rate GEM-TPC for P-bar ANDA

    International Nuclear Information System (INIS)

    Boehmer, F.V.; Angerer, H.; Dorheim, S.; Hoeppner, C.; Ketzer, B.; Konorov, I.; Neubert, S.; Paul, S.; Vandenbroucke, M.; Zhang, X.; Berger, M.; Cusanno, F.; Fabbietti, L.; Lalik, R.; Beck, R.; Kaiser, D.; Lang, M.; Schmitz, R.; Walther, D.; Winnebeck, A.

    2011-01-01

    The P-bar ANDA fixed target experiment planned at FAIR will investigate fundamental questions of non-perturbative QCD. It makes use of a cooled antiproton beam (momentum: 1.5 to 15GeV/c) and will reach luminosities of up to 2.10 32 cm -2 s -1 , yielding a p-bar p-annihilation rate of 2.10 7 s -1 . One option for the central tracker of P-bar ANDA is a cylindrical, ungated, continuously running TPC with GEM-based gas amplification stage.

  16. Gems of combinatorial optimization and graph algorithms

    CERN Document Server

    Skutella, Martin; Stiller, Sebastian; Wagner, Dorothea

    2015-01-01

    Are you looking for new lectures for your course on algorithms, combinatorial optimization, or algorithmic game theory?  Maybe you need a convenient source of relevant, current topics for a graduate student or advanced undergraduate student seminar?  Or perhaps you just want an enjoyable look at some beautiful mathematical and algorithmic results, ideas, proofs, concepts, and techniques in discrete mathematics and theoretical computer science?   Gems of Combinatorial Optimization and Graph Algorithms is a handpicked collection of up-to-date articles, carefully prepared by a select group of international experts, who have contributed some of their most mathematically or algorithmically elegant ideas.  Topics include longest tours and Steiner trees in geometric spaces, cartograms, resource buying games, congestion games, selfish routing, revenue equivalence and shortest paths, scheduling, linear structures in graphs, contraction hierarchies, budgeted matching problems, and motifs in networks.   This ...

  17. Radiotherapy of heterotopic bone formation in patients with paraplegia. Preliminary results; Strahlentherapie heterotoper Ossifikationen bei Querschnittsgelaehmten. Praeliminaere Ergebnisse

    Energy Technology Data Exchange (ETDEWEB)

    Sautter-Bihl, M.L. [Klinik fuer Strahlentherapie, Staedtisches Klinikum Karlsruhe (Germany); Liebermeister, E. [Klinik fuer Strahlentherapie, Staedtisches Klinikum Karlsruhe (Germany); Heinze, H.G. [Klinik fuer Strahlentherapie, Staedtisches Klinikum Karlsruhe (Germany); Nanassy, A. [Klinik fuer Orthopaedie, Rehabilitationskrankenhaus Langensteinbach (Germany); Stoltze, D. [Klinik fuer Orthopaedie, Rehabilitationskrankenhaus Langensteinbach (Germany)

    1995-08-01

    In 20 patients with paralysis, 25 regions were irradiated with (mostly) 10 Gy in single fractions of 2 to 2.5 Gy using 8 MW photons. In 15 patients radiotherapy was performed as a primary treatment in the status of myositis; 7 patients were treated after (subtotal) resection of already manifest ossifications (2 patients were treated twice, primarily and postoperatively). In a minimum follow-up 12 weeks, none of the 20 irradiated patients showed any progression of the developing or already manifest ossification; thus mobilisation and rehabilitation could be carried out as desired. No side effects occurred. The preliminary results of the present study suggest that radiotherapy is an effective local treatment with minimal side effects for the prevention of heterotopic bone formation in patients with paraplegia. (orig.) [Deutsch] Bei 20 Patienten (18 Maenner, zwei Frauen, Alter 19 bis 62 Jahre) mit Querschnittssyndrom wurden 25 Regionen mit ueberwiegend 10 Gy a 2 bis 2,5 Gy Einzeldosis mit 8-MW-Photonen bestrahlt. Die Radiatio erfolgte bei 15 Patienten als Primaerprophylaxe im entzuendlichen Stadium, bei sieben Patienten sekundaer nach (subtotaler) Resektion von Ossifikationen (zwei Patienten wurden sowohl primaer als auch sekundaer bestrahlt). Bei einer Mindestnachbeobachtungszeit von zwoelf Wochen trat in keinem Fall eine Progression der sich entwickelnden bzw. bereits bestehenden heterotopen Ossifikationen auf: saemtliche Patienten konnten wunschgemaess mobilisiert und im Rahmen ihrer neurologischen Ausfaelle rehabilitiert werden. Nebenwirkungen traten nicht auf. Die vorliegende praeliminaeren Ergebnisse deuten hin, dass die Strahlentherapie eine effektive und nebenwirkungsarme lokale Therapie zur Verhinderung heterotoper Ossifikationen beim Querschnittssyndrom darstellt. (orig.)

  18. MR arthrography of the shoulder: possible indications for clinical use; Einsatzmoeglichkeiten der MR-Arthrographie bei Erkrankungen des Schultergelenkes

    Energy Technology Data Exchange (ETDEWEB)

    Kreitner, K.F. [Mainz Univ. (Germany). Klinik mit Poliklinik fuer Radiologie; Grebe, P. [Mainz Univ. (Germany). Klinik mit Poliklinik fuer Radiologie; Kersjes, W. [Mainz Univ. (Germany). Klinik mit Poliklinik fuer Radiologie; Runkel, M. [Mainz Univ. (Germany). Klinik fuer Unfallchirurgie; Kirschner, P. [Elisabeth-Hospital, Mainz (Germany). Abt. fuer Unfall- und Wiederherstellungschirurgie St. Vincenz; Schild, H.H. [Mainz Univ. (Germany). Klinik mit Poliklinik fuer Radiologie

    1994-02-01

    In a prospective study possible indications for MR arthrography of the shoulder were evaluated. 37 patients were examined before and after intraarticular administration of a 2-mmolar solution of Gd-DTPA. MR arthrography was performed if there was no joint effusion and/or an uncertain finding concerning the rotator cuff or the capsulolabral complex on plain MR images. MR arthrography leads to a better demonstration of labrum pathology in 11/22 patients and to a superior delineation of the capsuloligamentous apparatus in 20/22 cases. In 9/15 patients with impingement lesions MR arthrography allowed a differentiation of severe tendinitis from partial and small full-thickness tears of the rotator cuff. MR arthrography of the shoulder joint enhances the accuracy of MR in case of an uncertain finding on plain MR images. (orig.) [Deutsch] In einer prospektiven Studie sollten Einsatzmoeglichkeiten der MR-Arthrographie bei Erkrankungen des Schultergelenkes herausgearbeitet werden. 37 Patienten wurden sowohl nativ als auch nach intraartikulaerer Gabe einer 2mmolaren Gd-DTPA-Loesung untersucht. Voraussetzungen fuer die KM-Gabe waren ein fehlender Gelenkerguss und/oder ein unklarer Befund des Labrum-Kapsel-Komplexes oder der Rotatorenmanschette in der Nativuntersuchung. Durch die MR-Arthrographie wurde bei 11/22 Patienten eine verbesserte Darstellung der Labrumpathologie erzielt; in 20/22 Faellen ergabe sich eine zuverlaessige Beurteilung der Gelenkkapsel. Bei 9/15 Patienten mit Erkrankungen der Rotatorenmanschette konnten Tendinitiden von partiellen und kleinen kompletten Rotatorenmanschettenrupturen sicher differenziert werden. Die MR-Arthrographie des Schultergelenkes fuehrt bei nicht eindeutigen Befunden in der Nativuntersuchung zu einer verbesserten Treffsicherheit der MR-Diagnostik. (orig.)

  19. Properties of thick GEM in low-pressure deuterium

    International Nuclear Information System (INIS)

    Lee, C S; Ota, S; Tokieda, H; Kojima, R; Watanabe, Y N; Uesaka, T

    2014-01-01

    Deuteron inelastic scattering (d, d') provides a promising spectroscopic tool to study nuclear incompressibility. In studies of deuteron inelastic scattering of unstable nuclei, measurements of low-energy recoiled particles is very important. In order to perform these measurements, we are developing a GEM-TPC based gaseous active target, called CAT (Center for nuclear study Active Target), operated with pure deuterium gas. The CAT has been tested with deuterium gas at 1 atm and 100-μm-thick GEMs. The low-pressure operation of CAT is planned in order to improve the detection capability for lower-energy recoil particles. A 400 μm-thick gas electron multiplier (THGEM) was chosen for the low-pressure operation of CAT. However, the properties of THGEM in low-pressure deuterium are currently undocumented. In this work, the performance of THGEM with low-pressure pure deuterium gas has been investigated. The effective gas gain of THGEM has been measured in various conditions using a 5.5-MeV 241 Am alpha source. The effective gas gain was measured for 0.2-, 0.3- and 0.4-atm deuterium gas and a gas gain of about 10 3 was achieved by a double THGEM structure at 0.2 atm. The maximum achieved gain decreased with increasing gas pressure. The dependences of the effective gas gain on the electric field strengths of the drift, transfer and induction regions were investigated. The gain stability as a function of time in hydrogen gas was also tested and a relaxation time of THGEM of about 60 hours was observed with a continuous irradiation of alpha particles, which is significantly longer than previous studies have reported. We have tried to evaluate the gas gain of THGEM in deuterium gas by considering only the Townsend ionization process; however, it turned out that more phenomenological aspects, such as transfer efficiency, should be included in the evaluation. The basic properties of THGEM in low-pressure deuterium have been investigated for the first time

  20. Properties of thick GEM in low-pressure deuterium

    Science.gov (United States)

    Lee, C. S.; Ota, S.; Tokieda, H.; Kojima, R.; Watanabe, Y. N.; Uesaka, T.

    2014-05-01

    Deuteron inelastic scattering (d, d') provides a promising spectroscopic tool to study nuclear incompressibility. In studies of deuteron inelastic scattering of unstable nuclei, measurements of low-energy recoiled particles is very important. In order to perform these measurements, we are developing a GEM-TPC based gaseous active target, called CAT (Center for nuclear study Active Target), operated with pure deuterium gas. The CAT has been tested with deuterium gas at 1 atm and 100-μm-thick GEMs. The low-pressure operation of CAT is planned in order to improve the detection capability for lower-energy recoil particles. A 400 μm-thick gas electron multiplier (THGEM) was chosen for the low-pressure operation of CAT. However, the properties of THGEM in low-pressure deuterium are currently undocumented. In this work, the performance of THGEM with low-pressure pure deuterium gas has been investigated. The effective gas gain of THGEM has been measured in various conditions using a 5.5-MeV 241Am alpha source. The effective gas gain was measured for 0.2-, 0.3- and 0.4-atm deuterium gas and a gas gain of about 103 was achieved by a double THGEM structure at 0.2 atm. The maximum achieved gain decreased with increasing gas pressure. The dependences of the effective gas gain on the electric field strengths of the drift, transfer and induction regions were investigated. The gain stability as a function of time in hydrogen gas was also tested and a relaxation time of THGEM of about 60 hours was observed with a continuous irradiation of alpha particles, which is significantly longer than previous studies have reported. We have tried to evaluate the gas gain of THGEM in deuterium gas by considering only the Townsend ionization process; however, it turned out that more phenomenological aspects, such as transfer efficiency, should be included in the evaluation. The basic properties of THGEM in low-pressure deuterium have been investigated for the first time.

  1. F-18-FDG PET of the thyroid in Graves` disease; F-18-FDG-PET der Schilddruese bei Morbus Basedow

    Energy Technology Data Exchange (ETDEWEB)

    Boerner, A.R.; Voth, E.; Schicha, H. [Klinik und Poliklinik fuer Nuklearmedizin, Koeln Univ. (Germany); Wienhard, K.; Wagner, R. [Max-Planck-Institut fuer Neurologische Forschung, Koeln (Germany)

    1998-12-31

    This study evaluates F-18-FDG PET of the thyroid in Graves` disease. Methods: Thirty patients were investigated the day before radioiodine therapy, 15 patients 3-10 days after radioiodine therapy. Twenty patients with cancer of the head or neck and normal thyroid function served as controls. Results: F-18-FDG uptake was higher in Graves` disease patients than in controls. Negative correlations of F-18-FDG uptake with half-life of radioiodine and absorbed radiation dose due to radioiodine therapy were found along with a positive correlation to autoantibody levels. Conclusion: Thus F-18-FDG PET is likely to give information on the biological activity of Graves` disease as well as on early radiation effects. (orig.) [Deutsch] Ziel: Diese Studie evaluiert F-18-Fluoro-Deoxy-Glukose (F-18-FDG) PET der Schilddruese bei Patienten mit M. Basedow. Methoden: 30 Patienten wurden am Tag vor Radioiod-Therapie, 15 Patienten am 3.-10. Tag nach Radioiodtherapie untersucht. 20 Patienten mit Kopf/Halstumoren und normaler Schilddruesenfunktion dienten als Kontrollgruppe. Ergebnisse: Die F-18-FDG-Aufnahme in der Schilddruese war signifikant hoeher bei Patienten mit M-Basedow im Vergleich zu den Kontrollen. Sie stieg mit hoeheren, antithyreoidalen Antikoerpern und sank bei laengerer I-131-Halbwertzeit. Es bestand eine Korrelation einer reduzierten Glukose-Utilisation bei hoeherer absorbierter Schilddruesendosis nach Radioiod-Therapie. Schlussfolgerung: Damit erscheint die F-18-FDG-PET-Untersuchung zur biologischen Aktivitaetsbeurteilung des M. Basedow und Darstellung von fruehen Strahleneffekten geeignet. (orig.)

  2. GEM-AQ/EC, an on-line global multi-scale chemical weather modelling system: model development and evaluation of global aerosol climatology

    Directory of Open Access Journals (Sweden)

    S. L. Gong

    2012-09-01

    Full Text Available A global air quality modeling system GEM-AQ/EC was developed by implementing tropospheric chemistry and aerosol processes on-line into the Global Environmental Multiscale weather prediction model – GEM. Due to the multi-scale features of the GEM, the integrated model, GEM-AQ/EC, is able to investigate chemical weather at scales from global to urban domains. The current chemical mechanism is comprised of 50 gas-phase species, 116 chemical and 19 photolysis reactions, and is complemented by a sectional aerosol module CAM (The Canadian Aerosol Module with 5 aerosols types: sulphate, black carbon, organic carbon, sea-salt and soil dust. Monthly emission inventories of black carbon and organic carbon from boreal and temperate vegetation fires were assembled using the most reliable areas burned datasets by countries, from statistical databases and derived from remote sensing products of 1995–2004. The model was run for ten years from from 1995–2004 with re-analyzed meteorology on a global uniform 1° × 1° horizontal resolution domain and 28 hybrid levels extending up to 10 hPa. The simulating results were compared with various observations including surface network around the globe and satellite data. Regional features of global aerosols are reasonably captured including emission, surface concentrations and aerosol optical depth. For various types of aerosols, satisfactory correlations were achieved between modeled and observed with some degree of systematic bias possibly due to large uncertainties in the emissions used in this study. A global distribution of natural aerosol contributions to the total aerosols is obtained and compared with observations.

  3. Prognostic value of cardiovascular MRI in diabetics; Prognostischer Wert der kardiovaskulaeren MRT bei Diabetikern

    Energy Technology Data Exchange (ETDEWEB)

    Schlett, C.L.; Bertheau, R.C.; Kauczor, H.U.; Weckbach, S. [Universitaetsklinikum Heidelberg, Klinik fuer Diagnostische und Interventionelle Radiologie, Heidelberg (Germany)

    2015-04-01

    Risikostratifizierung von Noeten ist. Die klinische Untersuchung und die Bestimmung von Blutwerten dienen bei Diabetikern typischerweise zur Risikostratifizierung bzgl. kardio(zerebro)vaskulaerer Ereignisse in der Zukunft. Sowohl die Kardio- als auch die Ganzkoerper-MRT stellen standardisierte Verfahren in der klinischen Diagnostik dar. Deren Stellenwert bei der Vorhersage von Ereignissen mit entsprechender Risikostratifizierung bei Diabetikern gewinnt basierend auf aktuellen Studienergebnissen zunehmend an Bedeutung. Late Gadolinium Enhancement (LGE) im Kardio-MRT detektiert bei bis zu 30 % der Diabetiker stumme Myokardischaemien, die mit einer Hazard Ratio von 3-6 mit kardiovaskulaeren Ereignissen assoziiert sind. Ebenfalls zeigen linksventrikulaere Wandbewegungsstoerungen sowie eine erniedrigte Ejektionsfraktion einen prognostischen Wert. Im Ganzkoerper-MRT sind der Vessel-Score und Karotisstenosen zusaetzliche Praediktoren fuer kardio(zerebro)vaskulaere Ereignisse. Die MRT-basierte Vorhersage kardio(zerebro)vaskulaerer Ereignisse bietet einen signifikanten Mehrwert zur klassischen Risikostratifizierung bei Diabetikern. Jedoch erlaubt nur die umfassende Ganzkoerper-MRT-Untersuchung Patienten zu identifizieren, die ueber einen Zeitraum von 6 Jahren komplett frei von kardio(zerebro)vaskulaeren Ereignissen bleiben. Die Kardio-MRT, insbesondere die Erfassung von LGE, empfiehlt sich fuer die Vorhersage von Ereignissen. Die Ganzkoerper-MRT stellt einen prognostischen Mehrwert dar, deren klinische Relevanz in weiteren Studien geklaert werden muss. (orig.)

  4. Lingua(gem sob duas perspectivas teóricas

    Directory of Open Access Journals (Sweden)

    Lidiomar José Mascarello

    2010-02-01

    Destacaremos nesse breve percurso teórico dois olhares possíveis para esse fenômeno, a língua(gem, que é tão natural e ao mesmo tempo tão complexo de ser explicado e entendido. De um lado, questões psíquicas individuais, como um processo evolutivo que opera em escala de tempo e que depende da maturação dos processos neurais e de toda rede neuronial e da capacidade inata do sujeito, ou seja, uma visão com tendências mais cognitivista, e por outro, da exposição à interação sócio-ambiental, de cunho interacionista, pois, acreditamos que são complementares e não restritivas ou excludentes.

  5. Auto-Ignition of Iso-Stoichiometric Blends of Gasoline-Ethanol-Methanol (GEM) in SI, HCCI and CI Combustion Modes

    KAUST Repository

    Waqas, Muhammad

    2017-03-28

    Gasoline-ethanol-methanol (GEM) blends, with constant stoichiometric air-to-fuel ratio (iso-stoichiometric blending rule) and equivalent to binary gasoline-ethanol blends (E2, E5, E10 and E15 in % vol.), were defined to investigate the effect of methanol and combined mixtures of ethanol and methanol when blended with three FACE (Fuels for Advanced Combustion Engines) Gasolines, I, J and A corresponding to RON 70.2, 73.8 and 83.9, respectively, and their corresponding Primary Reference Fuels (PRFs). A Cooperative Fuel Research (CFR) engine was used under Spark Ignition and Homogeneous Charge Compression Ignited modes. An ignition quality tester was utilized in the Compression Ignition mode. One of the promising properties of GEM blends, which are derived using the iso-stoichiometric blending rule, is that they maintain a constant octane number, which has led to the introduction of methanol as a drop-in fuel to supplement bio-derived ethanol. A constant RON/HCCI fuel number/derived Research octane number property was observed in all three combustion modes for high RON fuels, but for low RON fuels, the iso-stoichiometric blending rule for constant octane number did not appear to be valid. The chemical composition and octane number of the base fuel also influenced the behavior of the GEM blends under different conditions.

  6. Auto-Ignition of Iso-Stoichiometric Blends of Gasoline-Ethanol-Methanol (GEM) in SI, HCCI and CI Combustion Modes

    KAUST Repository

    Waqas, Muhammad; Naser, Nimal; Sarathy, Mani; Feijs, Jeroen; Morganti, Kai; Nyrenstedt, Gustav; Johansson, Bengt

    2017-01-01

    Gasoline-ethanol-methanol (GEM) blends, with constant stoichiometric air-to-fuel ratio (iso-stoichiometric blending rule) and equivalent to binary gasoline-ethanol blends (E2, E5, E10 and E15 in % vol.), were defined to investigate the effect of methanol and combined mixtures of ethanol and methanol when blended with three FACE (Fuels for Advanced Combustion Engines) Gasolines, I, J and A corresponding to RON 70.2, 73.8 and 83.9, respectively, and their corresponding Primary Reference Fuels (PRFs). A Cooperative Fuel Research (CFR) engine was used under Spark Ignition and Homogeneous Charge Compression Ignited modes. An ignition quality tester was utilized in the Compression Ignition mode. One of the promising properties of GEM blends, which are derived using the iso-stoichiometric blending rule, is that they maintain a constant octane number, which has led to the introduction of methanol as a drop-in fuel to supplement bio-derived ethanol. A constant RON/HCCI fuel number/derived Research octane number property was observed in all three combustion modes for high RON fuels, but for low RON fuels, the iso-stoichiometric blending rule for constant octane number did not appear to be valid. The chemical composition and octane number of the base fuel also influenced the behavior of the GEM blends under different conditions.

  7. Antigranulocyte scintigraphy of septic loosening of hip prosthesis: influence of different analyzing methods; Antigranulozytenszintigraphie bei septischer Hueft-Endoprothesen-Lockerung: Einfluss unterschiedlicher Auswertemethoden

    Energy Technology Data Exchange (ETDEWEB)

    Klett, R.; Steiner, D.; Puille, M.; Khalisi, A.; Bauer, R. [Giessen Univ. (Germany). Klinik fuer Nuklearmedizin; Matter, H.P.; Stuerz, H. [Giessen Univ. (Germany). Orthopaedische Klinik

    2001-06-01

    Diagnosis of infection with help of antigranulocyte scintigraphy near body stem is difficult because of contemporary visualisation of bone marrow. Therefore, we investigated, whether it is possible to improve the accuracy in diagnosing septic loosening of hip endoprosthesis by changing the analyzing methods. Methods: In 28 patients, the results of a visual interpretation of late scan, a visual interpretation and a quantitative interpretation of time-activity-course were compared. These results were verified by histology respectively microbiology. Results: Histological and microbiological verification found 14 septic loosening and 14 aseptic loosening of the hip protheses. Therefore, sensitivity, specificity, negative and positive predictive value for the visual interpretation of late scan were 0.86, 0.57, 0.80 and 0.67. For visual and quantitative interpretation of time-activity-course we found 0.86, 0.79, 0.85 and 0.80 respectively 1, 0.93, 1, 0.93. For interobserver agreement we found kappa coefficients of 0.28 {+-} 0.2 for visual interpretation of late scan, 0.48 {+-} 0.17 for visual interpretation and 1.0 {+-} 0 for quantitative interpretation of time-activity-course. Conclusion: In all investigated values quantitative interpretation of time-activity-course was superior to the other analyzing methods. Therefore, antigranulocyte scintigraphy for septic loosening of hip endoprosthesis should be interpreted quantitatively. (orig.) [German] Bei der Entzuendungsdiagnostik mittels Antigranulozytenszintigraphie ergeben sich in der Naehe des Koerperstammes aufgrund der gleichzeitigen Knochenmarkdarstellung Beurteilungsschwierigkeiten, da nicht immer sicher zwischen entzuendlichen Fokus beziehungsweise Knochenmark zu unterscheiden ist. Es wurde daher untersucht, ob bei der Diagnostik der septischen Hueft-Endoprothesen-Lockerung durch Aenderung des Auswerteverfahrens eine Verbesserung der Aussage zu erzielen ist. Methode: Bei 28 Patienten wurden die Ergebnisse einer

  8. A Continuously Running High-Rate GEM-TPC for P-bar ANDA

    Energy Technology Data Exchange (ETDEWEB)

    Boehmer, F.V., E-mail: felix.valentin.boehmer@cern.ch [Technische Universitaet Muenchen Physik Department, James-Franck-Strasse, 85748 Garching (Germany); Angerer, H.; Dorheim, S.; Hoeppner, C.; Ketzer, B.; Konorov, I.; Neubert, S.; Paul, S.; Vandenbroucke, M.; Zhang, X. [Technische Universitaet Muenchen Physik Department, James-Franck-Strasse, 85748 Garching (Germany); Berger, M.; Cusanno, F.; Fabbietti, L.; Lalik, R. [Excellence Cluster Universe, Muenchen (Germany); Beck, R.; Kaiser, D.; Lang, M.; Schmitz, R.; Walther, D.; Winnebeck, A. [Helmholtz-Institut fuer Strahlen- und Kernphysik, Bonn (Germany)

    2011-06-15

    The P-bar ANDA fixed target experiment planned at FAIR will investigate fundamental questions of non-perturbative QCD. It makes use of a cooled antiproton beam (momentum: 1.5 to 15GeV/c) and will reach luminosities of up to 2.10{sup 32}cm{sup -2}s{sup -1}, yielding a p-bar p-annihilation rate of 2.10{sup 7}s{sup -1}. One option for the central tracker of P-bar ANDA is a cylindrical, ungated, continuously running TPC with GEM-based gas amplification stage.

  9. Morbidity Profile of Child Labor at Gem Polishing Units of Jaipur, India

    Directory of Open Access Journals (Sweden)

    RR Tiwari

    2014-07-01

    Full Text Available Background: There are millions of working children worldwide. Several causes are suggested for this social evil of which poverty plays a significant role in whether a child will work. Objective: To determine the morbidity profile in the working children of gem polishing units of Jaipur, India and assess some of its associated socio-economic factors. Methods: The present cross-sectional study included 586 gem polishing working children. Using interview, the demographic characteristics, occupational and clinical history of participants were recorded. The reason for taking up the job, income from the job and their desire to attend the school were also asked to assess the social causes of child labor in this region. Results: The mean±SD age of the working children was 11.3±5.3 years. In most of the instances, parents compelled the child to take up the job. Supposed to increase the family income substantially, the child labor activity failed to do so. On the other hand, the children suffered from several occupational health problems like eyestrain, headache, gastrointestinal complaints (eg, abdominal pain, nausea, vomiting, and diarrhea, musculoskeletal symptoms (eg, back pain, pain in limbs, neck pain, and joint pains and skin diseases (eg, scabies, dermatitis. Conclusion: It seems that the social factors forcing the children to work in the studied region, result in deterioration of their health and affect their growth.

  10. Umgang mit Antithrombotika bei Operationen an der Haut vor und nach Publikation der entsprechenden S3-Leitlinie.

    Science.gov (United States)

    Gaskins, Matthew; Dittmann, Martin; Eisert, Lisa; Werner, Ricardo Niklas; Dressler, Corinna; Löser, Christoph; Nast, Alexander

    2018-03-01

    Laut einer Befragung im Jahre 2012 war der Umgang mit Antithrombotika bei dermatochirurgischen Eingriffen in Deutschland sehr heterogen. 2014 wurde erstmals eine evidenzbasierte Leitlinie zu diesem Thema veröffentlicht. Es wurde eine anonyme Befragung derselben Stichprobe zum Umgang mit Antithrombotika sowie zu Kenntnissen der Leitlinie durchgeführt. Die Ergebnisse wurden als relative Häufigkeiten berichtet und denen aus 2012 gegenübergestellt. 208 Antwortbögen wurden ausgewertet (Rücklaufquote: 36,6 %). Die große Mehrheit der Dermatologen erklärte, kleinere Eingriffe unter Fortführung der Therapie mit Phenprocoumon, niedrig dosierter Acetylsalicylsäure (≤ 100 mg) und Clopidogrel sowie mit direkten oralen Antikoagulanzien durchzuführen. Bei größeren Eingriffen war der Umgang hingegen weiterhin heterogen, insbesondere unter niedergelassenen Dermatologen. Der Anteil der Dermatologen, die Phenprocoumon, Acetylsalicylsäure und Clopidogrel leitlinienkonform verwendeten, hat sich insgesamt vergrößert. Führten 2012 beispielsweise 53,8 % der Klinikärzte bzw. 36,3 % der niedergelassenen Dermatologen eine große Exzision unter Fortführung der Therapie mit niedrig dosierter Acetylsalicylsäure durch, taten dies 2017 90,2 % bzw. 57,8 % (Phenprocoumon: 33,8 % bzw. 11,9 % auf 63,9 % bzw. 29,9 %; Clopidogrel: 36,9 % bzw. 23,2 % auf 63,9 % bzw. 30,6 %). Unter den Klinikärzten war ein hoher Anteil mit der Leitlinie vertraut und fand diese hilfreich. Eine Zunahme des leitlinienkonformen Verhaltens war bei allen Eingriffen zu verzeichnen. Bei größeren Eingriffen zeigte sich trotz deutlicher Verbesserung die Notwendigkeit verstärkter Anstrengungen zur Leitlinienumsetzung bzw. zur Identifizierung von Implementierungsbarrieren. © 2018 Deutsche Dermatologische Gesellschaft (DDG). Published by John Wiley & Sons Ltd.

  11. Erkrankungen des Traumaspektrums bei ruandischen Waisen des Genozids : Epidemiologie und Behandlung

    OpenAIRE

    Schaal, Susanne

    2006-01-01

    Im Jahre 1994 kamen in Ruanda innerhalb von 100 Tagen fast eine Million Menschen auf brutalste Weise ums Leben. Vorliegende Studie untersuchte die Traumakonfrontation und mentalen Gesundheitseffekte dieses staatlich organisierten Genozids bei ruandischen Waisen (n = 118) 11 Jahre nach dem Völkermord. Die Stichprobe setzte sich aus Vollwaisen zusammen, die entweder in kindergeführten Haushalten oder in Waisenheimen der Hauptstadt Kigali lebten. Risikofaktoren wurden analysiert und die Wirksamk...

  12. A GEM-TPC prototype with low-Noise highly integrated front-end electronics for linear collider studies

    CERN Document Server

    Kappler, Steffen; Kaminski, Jochen; Ledermann, Bernhard; Müller, Thomas; Ronan, Michael T; Ropelewski, Leszek; Sauli, Fabio; Settles, Ronald

    2004-01-01

    Connected to the linear collider project, studies on the readout of time projection chambers (TPCs) based on the gas electron multiplier (GEM) are ongoing. Higher granularity and intrinsically suppressed ion feedback are the major advantages of this technology. After a short discussion of these issues, we present the design of a small and very flexible TPC prototype, whose cylindrical drift volume can be equipped with endcaps of different gas detector types. An endcap with multi-GEM readout is currently set up and successfully operated with a low-noise highly integrated front-end electronics. We discuss results of measurements with this system in high intensity particle beams at CERN, where 99.3 plus or minus 0.2% single-pad-row efficiency could be achieved at an effective gain of 2.5 multiplied by 10**3 only, and spatial resolutions down to 63 plus or minus 3 mum could be demonstrated. Finally, these results are extrapolated to the high magnetic field in a linear collider TPC. 5 Refs.

  13. Craniocerebral trauma. Magnetic resonance imaging of diffuse axonal injury; Schaedel-Hirn-Trauma. MRT bei diffuser axonaler Verletzung

    Energy Technology Data Exchange (ETDEWEB)

    Mallouhi, A. [Medizinische Universitaet Wien, Allgemeines Krankenhaus, Abteilung fuer Neuro- und Muskuloskelettale Radiologie, Klinik fuer Radiologie und Nuklearmedizin, Wien (Austria)

    2014-09-15

    Acceleration-deceleration rotational brain trauma is a common cause of disability or death in young adults and often leads to a focal destruction of axons. The resulting pathology, axonal shear injury is referred to as diffuse axonal injury (DAI). The DAI-associated lesions occur bilaterally, are widely dispersed and have been observed in the surface and deep white matter. They are found near to and far from the impact site. When DAI is clinically suspected, magnetic resonance imaging (MRI) is the method of choice for further clarification, especially in patients where cranial computed tomography (CT) is inconspicuous. To investigate the presence of DAI after traumatic brain injury (TBI), a multimodal MRI approach is applied including the common structural and also functional imaging sequences. For structural MRI, fluid-attenuated inversion recovery (FLAIR) weighted and susceptibility contrast imaging (SWI) are the sequences mainly used. The SWI technique is extremely sensitive to blood breakdown products, which appear as small signal voids at three locations, at the gray-white interface, in the corpus callosum and in the brain stem. Functional MRI comprises a group of constantly developing techniques that have great potential in optimal evaluation of the white matter in patients after craniocerebral trauma. These imaging techniques allow the visualization of changes associated with shear injuries, such as functional impairment of axons and decreased blood flow and abnormal metabolic activity of the brain parts affected. The multimodal MRI approach in patients with DAI results in a more detailed and differentiated representation of the underlying pathophysiological changes of the injured nerve tracts and helps to improve the diagnostic and prognostic accuracy of MRI. When DAI is suspected multimodal MRI should be performed as soon as possible after craniocerebral injury. (orig.) [German] Das Rotationstrauma des Gehirns ist bei jungen Erwachsenen ein haeufiger Grund

  14. Berechnung verkehrlicher Substitutionseffekte im Personenverkehr bei Online-Shopping

    Science.gov (United States)

    Nerlich, Mark R.; Schiffner, Felix; Vogt, Walter; Rauh, Jürgen; Breidenbach, Petra

    Für Güter des täglichen, mittelfristigen und langfristigen Bedarfs sowie für das Beispiel Baumarktartikel wird das Potenzial für Personenverkehrsaufwand von Einkaufsaktivtäten quantitativ abgeschätzt. Die entwickelten Algorithmen behandeln die einkaufsvorbereitende Information und den eigentlichen Einkauf, d.h. den Erwerb eines Gutes, separat. Informationsaktivitäten haben insbesondere bei höherwertigen Gütern einen hohen Stellenwert und damit auch verkehrliche Relevanz. Wie Berechnungen zeigen, spart Online-Shopping Informations- und Einkaufsverkehrsaufwand im Pkw-Verkehr ein. Die notwendigen Eingangsdaten wie differenzierte Informations- und Einkaufshäufigkeiten sowie verkehrliche Parameter zu Verkehrsmittelwahl, Entfernungen und Wegekopplungen wurden aus eigenen Erhebungen gewonnen.

  15. Chloride ion-catalyzed generation of difluorocarbene for efficient preparation of gem-difluorinated cyclopropenes and cyclopropanes

    KAUST Repository

    Wang, Fei; Zhang, Wei; Zhu, Jieming; Li, Huaifeng; Huang, Kuo-Wei; Hu, Jinbo

    2011-01-01

    A chloride ion-catalyzed generation of difluorocarbene from a relatively non-toxic and inexpensive precursor, Me3SiCF2Cl (1), under mild and neutral conditions leads to an efficient preparation of gem-difluorocyclopropenes and difluorocyclopropanes through [2 + 1] cycloaddition reactions with alkynes and alkenes, respectively. © 2011 The Royal Society of Chemistry.

  16. Psychologie körperlicher Aktivität bei Patienten mit Rückenschmerzen

    OpenAIRE

    Leonhardt, Corinna

    2008-01-01

    Die vorliegende Arbeit setzt sich mit den psychologischen Determinanten und Fördermöglichkeiten von körperlicher Aktivität bei Rückenschmerzpatienten auseinander, wobei Daten einer multizentrischen cluster-randomisierten Studie (N= 1378) genutzt werden. Der theoretische Hintergrund aller Originalarbeiten gibt einen Überblick zu neuen Erkenntnissen zum Rückenschmerz und zur Aktivitätsförderung in der Gesundheitspsychologie und ...

  17. Characterization of a glass GEM for sealed detectors application and reduction of charging-up effects

    CERN Document Server

    Erdal, Eran

    2014-01-01

    Apart from high energy physics experiments, there has been a great effort in recent years to incorporate MPGDs in many other applications i.e. medical treatments and imaging and home land security. However, MPGDs (as most gaseous detectors) are normally operated under a constant flushing of the gas. Their use thus turns them expensive since they rely on a constant gas supply and a suitable infrastructure, but most important is the loss of their portability. These reasons have pushed the community to search for other solutions, aiming for the development of sealed detectors. The demands for such is to be made out of low outgassing rate materials and possibly the use of only noble gas to avoid aging due to chemical activity of the ionized gas of the avalanche. The default material for GEM detectors - Polyimide (Kapton), is not suitable for a sealed detector because of its high outgassing rate, thus calling for new solutions. Moreover, GEMs, being essentially made out of an insulating material, pose a problem in...

  18. Use of quantitative molecular diagnostic methods to identify causes of diarrhoea in children: a reanalysis of the GEMS case-control study.

    Science.gov (United States)

    Liu, Jie; Platts-Mills, James A; Juma, Jane; Kabir, Furqan; Nkeze, Joseph; Okoi, Catherine; Operario, Darwin J; Uddin, Jashim; Ahmed, Shahnawaz; Alonso, Pedro L; Antonio, Martin; Becker, Stephen M; Blackwelder, William C; Breiman, Robert F; Faruque, Abu S G; Fields, Barry; Gratz, Jean; Haque, Rashidul; Hossain, Anowar; Hossain, M Jahangir; Jarju, Sheikh; Qamar, Farah; Iqbal, Najeeha Talat; Kwambana, Brenda; Mandomando, Inacio; McMurry, Timothy L; Ochieng, Caroline; Ochieng, John B; Ochieng, Melvin; Onyango, Clayton; Panchalingam, Sandra; Kalam, Adil; Aziz, Fatima; Qureshi, Shahida; Ramamurthy, Thandavarayan; Roberts, James H; Saha, Debasish; Sow, Samba O; Stroup, Suzanne E; Sur, Dipika; Tamboura, Boubou; Taniuchi, Mami; Tennant, Sharon M; Toema, Deanna; Wu, Yukun; Zaidi, Anita; Nataro, James P; Kotloff, Karen L; Levine, Myron M; Houpt, Eric R

    2016-09-24

    Diarrhoea is the second leading cause of mortality in children worldwide, but establishing the cause can be complicated by diverse diagnostic approaches and varying test characteristics. We used quantitative molecular diagnostic methods to reassess causes of diarrhoea in the Global Enteric Multicenter Study (GEMS). GEMS was a study of moderate to severe diarrhoea in children younger than 5 years in Africa and Asia. We used quantitative real-time PCR (qPCR) to test for 32 enteropathogens in stool samples from cases and matched asymptomatic controls from GEMS, and compared pathogen-specific attributable incidences with those found with the original GEMS microbiological methods, including culture, EIA, and reverse-transcriptase PCR. We calculated revised pathogen-specific burdens of disease and assessed causes in individual children. We analysed 5304 sample pairs. For most pathogens, incidence was greater with qPCR than with the original methods, particularly for adenovirus 40/41 (around five times), Shigella spp or enteroinvasive Escherichia coli (EIEC) and Campylobactor jejuni o C coli (around two times), and heat-stable enterotoxin-producing E coli ([ST-ETEC] around 1·5 times). The six most attributable pathogens became, in descending order, Shigella spp, rotavirus, adenovirus 40/41, ST-ETEC, Cryptosporidium spp, and Campylobacter spp. Pathogen-attributable diarrhoeal burden was 89·3% (95% CI 83·2-96·0) at the population level, compared with 51·5% (48·0-55·0) in the original GEMS analysis. The top six pathogens accounted for 77·8% (74·6-80·9) of all attributable diarrhoea. With use of model-derived quantitative cutoffs to assess individual diarrhoeal cases, 2254 (42·5%) of 5304 cases had one diarrhoea-associated pathogen detected and 2063 (38·9%) had two or more, with Shigella spp and rotavirus being the pathogens most strongly associated with diarrhoea in children with mixed infections. A quantitative molecular diagnostic approach improved population

  19. High-precision GNSS ocean positioning with BeiDou short-message communication

    Science.gov (United States)

    Li, Bofeng; Zhang, Zhiteng; Zang, Nan; Wang, Siyao

    2018-04-01

    The current popular GNSS RTK technique would be not applicable on ocean due to the limited communication access for transmitting differential corrections. A new technique is proposed for high-precision ocean RTK, referred to as ORTK, where the corrections are transmitted by employing the function of BeiDou satellite short-message communication (SMC). To overcome the limitation of narrow bandwidth of BeiDou SMC, a new strategy of simplifying and encoding corrections is proposed instead of standard differential corrections, which reduces the single-epoch corrections from more than 1000 to less than 300 bytes. To solve the problems of correction delays, cycle slips, blunders and abnormal epochs over ultra-long baseline ORTK, a series of powerful algorithms were designed at the user-end software for achieving the stable and precise kinematic solutions on far ocean applications. The results from two long baselines of 240 and 420 km and real ocean experiments reveal that the kinematic solutions with horizontal accuracy of 5 cm and vertical accuracy of better than 15 cm are achievable by convergence time of 3-10 min. Compared to commercial ocean PPP with satellite telecommunication, ORTK is of much cheaper expense, higher accuracy and shorter convergence. It will be very prospective in many location-based ocean services.

  20. Análise da relação entre as informações contábeis e o risco sistemático no mercado brasileiro

    Directory of Open Access Journals (Sweden)

    Ana Luísa Gambi Cavallari Amorim

    2012-12-01

    Full Text Available De acordo com a literatura existente, as informações contábeis representam um importante estimador dos fluxos de caixa futuros da empresa, servindo, portanto, para fins de avaliação do risco de um investimento em ações. Isso porque tais informações refletem a realidade econômico-financeira da empresa em um dado período, possuindo, consequentemente, relação com o risco sistemático de um investimento, o que justifica sua utilização para fins de decisões relacionadas à composição de um portfólio de ações. Dentro desse contexto, o presente trabalho busca apresentar evidências empíricas da relação entre as informações contábeis e o risco sistemático no mercado brasileiro. Mais especificamente, objetiva-se analisar a relação entre os betas contábeis e os betas de mercado de companhias no Brasil. Para isso, foram selecionadas 97 empresas, da Bolsa de Valores, Mercadorias e Futuros de São Paulo (BM&FBOVESPA, de 15 setores econômicos, entre o 1º trimestre de 1995 e o 3º trimestre de 2009. Foram utilizadas 468 variáveis contábeis. Para operacionalizar a relação entre as variáveis foi utilizado um modelo de regressão com dados em painel. Os resultados evidenciaram que alguns betas contábeis podem explicar o beta de mercado e podem fazê-lo de forma antecipada, podendo, ainda, melhorar a previsão do beta de mercado quando associados a betas de mercado históricos. Por outro lado, a maior parte das versões de betas contábeis apresentou relação pouco significativa ou mesmo inexistente.

  1. Hyperonenproduktion in C+C- und Si+Si-Kollisionen bei 158 GeV pro Nukleon

    CERN Document Server

    Kraus, Ingrid

    2004-01-01

    Ultrarelativistische Schwerionenstöße werden seit etwa 15 Jahren untersucht, um Kernmaterie unter extremen Bedingungen zu erforschen; in Kollisionen schwerer Atomkerne kann bei hohen Einschußenergien Kernmaterie stark komprimiert und aufgeheizt werden. Die Bedeutung dieser Experimente wird durch Berechnungen der Quanten-Chromo-Dynamik auf raumzeitlichen Gittern hervorgehoben, die bei ausreichend hoher Energiedichte eine Phase voraussagen, in der die Quarks nicht mehr in Hadronen gebunden sind, sondern zusammen mit den Gluonen ein partonisches System ausbilden. Ist das System hinreichend groß und equilibriert, wird es als Quark-Gluon-Plasma bezeichnet. Die als Signatur für das Überschreiten der Phasengrenze vorgeschlagene erhöhte Produktion Seltsamkeit tragender Teilchen wurde in der Gegenüberstellung von elementaren Proton+Proton-Interaktionen und Kern+Kern-Stößen experimentell über einen weiten Energiebereich bestätigt. Eine solche Überhöhung kann aber auch durch rein hadronische Phänomene her...

  2. Quench and protection characteristics of the GEM test coil

    International Nuclear Information System (INIS)

    Chaniotakis, E.A.; Marston, P.G.

    1994-01-01

    The GEM test coil, will be wound from 70 m of conductor identical to that used in the full scale magnet. The coil configuration will duplicate the field distribution of the full scale magnet and current control will duplicate full scale current decay characteristics. Therefore, quench/protection analysis of this coil will reveal very important information about the behavior of the full scale model. Due to the uncertainty associated with the contact between the cable, the conduit and the sheath, a parametric analysis has been performed in order to determine and bracket the behavior. With no electrical contact the quench evolves normally until, due to heat transfer from the sheath into the cable, the superconductor temperature becomes critical and the entire length becomes normal

  3. Alu Mobile Elements: From Junk DNA to Genomic Gems

    Directory of Open Access Journals (Sweden)

    Sami Dridi

    2012-01-01

    Full Text Available Alus, the short interspersed repeated sequences (SINEs, are retrotransposons that litter the human genomes and have long been considered junk DNA. However, recent findings that these mobile elements are transcribed, both as distinct RNA polymerase III transcripts and as a part of RNA polymerase II transcripts, suggest biological functions and refute the notion that Alus are biologically unimportant. Indeed, Alu RNAs have been shown to control mRNA processing at several levels, to have complex regulatory functions such as transcriptional repression and modulating alternative splicing and to cause a host of human genetic diseases. Alu RNAs embedded in Pol II transcripts can promote evolution and proteome diversity, which further indicates that these mobile retroelements are in fact genomic gems rather than genomic junks.

  4. Transdermales Testosterongel verbessert die Parameter Sexualfunktion, Stimmung, Muskelkraft und Körperzusammensetzung bei hypogonadalen Männern

    Directory of Open Access Journals (Sweden)

    Wang C

    2003-01-01

    Full Text Available Eine Testosterontherapie bei hypogonadalen Männern sollte die klinisch manifesten Symptome eines Testosteronmangels im Sinne der Verbesserung der Sexualfunktion, der Vermehrung der Muskelmasse und -kraft sowie der Verringerung des Körperfettanteils korrigieren, ohne gleichzeitig nennenswerte Nebenwirkungen hervorzurufen. Wir haben bereits gezeigt, daß die Verabreichung eines neuen transdermalen Testosterongels an Männer mit Hypogonadismus zu dosisabhängigen Erhöhungen des Serumtestosteronspiegels in den Normalbereich erwachsener Männer führt. Wir berichten nun über die Auswirkungen einer 6-monatigen Behandlung mit diesem 1 %igen Testosterongel (50 bzw. 100 mg Testosteron pro Tag, enthalten in 5 bzw. 10 g Gel im Vergleich zu einem Penetrationsvermittler enthaltenden Testosteronpflaster (5 mg/Tag auf bestimmte Wirksamkeitsparameter bei 227 Männern mit Hypogonadismus. In den mit Testosterongel behandelten Gruppen wurde die Dosis am Studientag 90 auf 75 mg/Tag (enthalten in 7,5 g Gel erhöht oder gesenkt, wenn die Serumtestosteronspiegel über oder unter dem Normalbereich für erwachsene Männer lagen. In der Gruppe mit Testosteronpflaster wurde keine Dosisanpassung vorgenommen. Die Sexualfunktion und Stimmungsveränderungen wurden anhand eines Fragebogens, die Körperzusammensetzung anhand der DEXA-Methode und die Muskelkraft mit einer speziellen Technik("one repetitive maximum technique" durch Pressen der Beine und Arme ermittelt. Sexualfunktion und Stimmung verbesserten sich bereits am Tag 30 der Behandlung maximal, ohne Unterschied zwischen den Gruppen, und zeigten bei Fortsetzung der Therapie keine weitere Besserung. Die mittlere Muskelkraft bei der Beinpreßübung erhöhte sich in allen Gruppen nach 90 Behandlungstagen um 11 bis 13 kg und verbesserte sich anschließend bis zum Ende der Behandlung am Tag 180 nicht weiter. Zu mäßigen Steigerungen der Kraftentwicklung kam es auch an der Schulter- und Armmuskulatur. Nach 90 Tagen

  5. Cytoprotection with amifostine in the simultaneous radio-chemotherapy of recurrent head and neck cancer; Zytoprotection mit Amifostin im Rahmen der Radiochemotherapie bei vorbestrahlten Kopf-Hals-Karzinomen

    Energy Technology Data Exchange (ETDEWEB)

    Buentzel, J.; Weinaug, R.; Kuettner, K. [Zentralklinikum gGmbH Suedthueringen, Suhl (Germany). Klinik fuer Hals-Nasen-Ohren-Heilkunde, Plastische Operationen; Glatzel, M.; Froehlich, D. [Zentralklinikum gGmbH Suedthueringen, Suhl (Germany). Klinik fuer Strahlentherapie; Schuth, J. [Essex Pharma, Muenchen (Germany)

    1999-11-01

    Purpose: The radiotherapeutic possibilities are limited for patients with a recurrent or second head and neck cancer if the patient was already irradiated in the first therapy. In the presented study we investigated the changes of this situation due to the usage of amifostine in the case of re-irradiation (simultaneous radio-chemotherapy). Patients and methods: Between 1995 and 1997 we treated 14 patients with a recurrent or second malignancy of the head and neck region by a simultaneous radio-chemotherapy (20x1.5 Gy, Carboplatin 70 mg/m{sup 2} BSA on days 1 to 5 and 16 to 20, 500 mg amifostine prior to every carboplatin infusion). Six out of 14 patients got an additional brachytherapy (10 to 15 Gy) to increase the local dose because of a residual tomor. In 4 cases the treatment was an adjunctive one, following the surgical tumor debulking. Results: We have seen 3 complete remissions (21.4%), and 8 partial remissions (57.1%). The median time of observation in 13 months now. Three out of 14 patients died, 2 because of the tumor. Hematological toxicities: Side effects Grade 2 WHO were seen only in 1 patient. Acute non-hematological toxicities: Mucositis Grade 0/1 in 7 patients, mucositis Grade 2 in 7 patients, dysphagia Grade 0/1 in 9 patients, dysphagia Grade 2 in 5 patients, xerostomia Grade 1 in 9 patients, xerostomia Grade 2 in 3 patients. We registrated only 1 serious late toxicity due to radio-chemotherapy: 4 months after brachytherapy a patient (with laryngectomy) developed a submental fistula. Conclusion: These first results suggest that the usage of amifostine offers new potential ways for re-irradiation of patients with recurrent or second malignancies in the head neck region. (orig.) [German] Ziel: Bei einem Rezidiv- oder Zweitkarzinom im Kopf-Hals-Bereich sind die radiotherapeutischen Moeglichkeiten bei bereits vorbestrahlten Patienten sehr begrenzt. Inwieweit die Integration des selektiven Zytoprotektivums Amifostin in eine nochmalige Radiochemotherapie

  6. Pediatric radiological diagnostics in suspected child abuse; Kinderradiologische Diagnostik bei Verdacht auf Kindesmisshandlung

    Energy Technology Data Exchange (ETDEWEB)

    Erfurt, C.; Schmidt, U. [Technische Universitaet Dresden, Institut fuer Rechtsmedizin, Medizinische Fakultaet, Dresden (Germany); Hahn, G. [Universitaetsklinikum Carl Gustav Carus, Dresden, Abteilung Kinderradiologie, Institut und Poliklinik fuer Radiologische Diagnostik, Dresden (Germany); Roesner, D. [Universitaetsklinikum Carl Gustav Carus, Dresden, Klinik und Poliklinik fuer Kinderchirurgie, Dresden (Germany)

    2009-10-15

    Advanced and specialized radiological diagnostics are essential in the case of clinical suspicion of pediatric injuries to the head, thorax, abdomen, and extremities when there is no case history or when ''battered child syndrome'' is assumed on the basis of inadequate trauma. In particular, the aim of this sophisticated diagnostic procedure is the detection of lesions of the central nervous system (CNS) in order to initiate prompt medical treatment. If diagnostic imaging shows typical findings of child abuse, accurate documented evidence of the diagnostic results is required to prevent further endangerment of the child's welfare. (orig.) [German] Klinisch diagnostizierte Verletzungen an Kopf, Thorax, Abdomen oder Extremitaeten eines Kindes bei scheinbar leerer Anamnese oder Angabe eines inadaequaten Traumas erfordern beim Verdacht auf ein Battered-Child-Syndrom eine erweiterte und spezialisierte radiologische Diagnostik. Diese soll insbesondere im Bereich des ZNS Verletzungsfolgen erfassen, um therapeutische Massnahmen einleiten zu koennen. Bei typischen, auf eine Misshandlung hinweisenden radiologischen Befunden ist eine praezise beweissichere Befunddokumentation erforderlich, um eine weitere Kindeswohlgefaehrdung zu vermeiden. (orig.)

  7. A comparabilidade das escolhas contábeis na mensuração subsequente de ativos imobilizados, de ativos intangíveis e de propriedades para investimento

    OpenAIRE

    Souza, Flaida êmine Alves de

    2014-01-01

    A expertise comparabilidade, escolhas contábeis e valor justo é um dos temas mais controvertidos e carentes de discussões no cenário contábil atual. As escolhas contábeis são necessárias para que seja garantida a representação fidedigna, ao mesmo tempo em que seu uso discricionário pode diminuir a comparabilidade, que é esperada pelo IASB. Quando as escolhas contábeis se referem à opção entre os métodos do custo histórico e do valor justo, as controvérsias são ainda maiores. Em decorrência di...

  8. Instrumentos para determinação do índice de evidenciação de informações contábeis

    Directory of Open Access Journals (Sweden)

    Ilse Maria Beuren

    2015-04-01

    Full Text Available Este estudo descreve as características de instrumentos citados na literatura para apuração do índice de evidenciação de informações contábeis. Pesquisa descritiva foi realizada por meio de análise documental, com abordagem qualitativa. Os resultados focalizam cinco temáticas que exprimem os cuidados necessários ao elaborar uma métrica de mensuração de evidenciação de informações contábeis: público-alvo e definição de informação coercitiva e voluntária; escolha da base de dados; extensão do instrumento de coleta de dados; fatores que interferem na métrica; e testes de confiabilidade. O estudo pode contribuir na identificação de métricas para mensurar a extensão da evidenciação de informações contábeis pelas empresas.

  9. Magnetic resonance angiography and tomography of vertebrobasilar dissections; Magnetresonanzangiographie und Magnetresonanztomographie bei Dissektionen der A. vertebralis

    Energy Technology Data Exchange (ETDEWEB)

    Felber, S. [Inst. fuer Magnetresonanztomographie und Spektroskopie, Universitaetskliniken Innsbruck (Austria)]|[Universitaetsklinik fuer Radiologie, Klinische Abt. 2, Universitaetskliniken Innsbruck (Austria); Auer, A. [Inst. fuer Magnetresonanztomographie und Spektroskopie, Universitaetskliniken Innsbruck (Austria); Schmidauer, C. [Universitaetsklinik fuer Neurologie, Universitaetskliniken Innsbruck (Austria); Waldenberger, P. [Universitaetsklinik fuer Radiologie, Klinische Abt. 1, Universitaetskliniken Innsbruck (Austria); Aichner, F. [Inst. fuer Magnetresonanztomographie und Spektroskopie, Universitaetskliniken Innsbruck (Austria)

    1996-11-01

    wichtige Ursache von Schlaganfaellen bei juengeren Erwachsenen. Wir untersuchten die diagnostischen Moeglichkeiten der Magnetresonanzangiographie (MRA) in Kombination mit der Magnetresonanztomographie (MRT) bei vertebrobasilaeren Dissektionen anhand einer retrospektiven Analyse von 24 Patienten mit einer Vertebralisdissektion und einem Patienten mit einer Basilarisdissektion. Bei 24 von 25 Patienten (95,5%) wurden mit der Magnetresonanzangiographie abnorme Flussverhaeltnisse im disseziierten Gefaess erkannt. Die Sensitivitaet der konventionellen Angiographie war 100% und die des Ultraschalls 77%. In 7 Faellen (30,4%) ergab die Magnetresonanz spezifische Hinweise auf eine Dissektion (Doppellumen n=1, murales Haematom n=4, Pseudoaneurysma n=2). Demgegenueber standen 36,4% spezifische Befunde in der Angiographie. Dabei waren die spezifischen Resultate von MRT/MRA und Angiographie z.T. komplementaer, beide Methoden zusammen erzielten 43,5% Spezifitaet. Die kombinierte MRT und MRA kann bei etwa 1/3 der Patienten bereits die Diagnose einer Vertebralisdissektion stellen. Bei den anderen Patienten kann die Indikation zur konventionellen Angiographie verbessert werden. Dies gilt besonders fuer jene Patienten mit unspezifischen Prodromalsymptomen. Eine negative Magnetresonanzuntersuchung erzetzt bei Patienten mit hinweisenden Symptomen die konventionelle Angiographie allerdings nicht. Die Angiographie wird aufgrund der hoeheren Ortsaufloesung und der sicheren Beurteilbarkeit auch des proximalen V Abschnittes 1 vorerst diagnostischer Standard bleiben. (orig.)

  10. Gem1 and ERMES Do Not Directly Affect Phosphatidylserine Transport from ER to Mitochondria or Mitochondrial Inheritance

    DEFF Research Database (Denmark)

    Nguyen, Tammy T; Lewandowska, Agnieszka; Choi, Jae-Yeon

    2012-01-01

    the ER to mitochondria during the synthesis of phosphatidylethanolamine (PE), as PS to PE conversion is not affected in ERMES or gem1 mutants. In addition, we report that mitochondrial inheritance defects in ERMES mutants are a secondary consequence of mitochondrial morphology defects, arguing against...

  11. Modeling of serial data acquisition structure for GEM detector system in Matlab

    Science.gov (United States)

    Kolasinski, Piotr; Pozniak, Krzysztof T.; Czarski, Tomasz; Chernyshova, Maryna; Kasprowicz, Grzegorz; Krawczyk, Rafal D.; Wojenski, Andrzej; Zabolotny, Wojciech; Byszuk, Adrian

    2016-09-01

    This article presents method of modeling in Matlab hardware architecture dedicated for FPGA created by languages like VHDL or Verilog. Purposes of creating such type of model with its advantages and disadvantages are described. Rules presented in this article were exploited to create model of Serial Data Acquisition algorithm used in X-ray GEM detector system. Result were compared to real working model implemented in VHDL. After testing of basic structure, other two structures were modeled to see influence parameters of the structure on its behavior.

  12. Paradoxical effects of radioiodine therapy in functional thyroid autonomy and mild immunothyropathy; Paradoxe Effekte der Radiojodtherapie bei funktioneller Schilddruesenautonomie und milder Immunthyreopathie

    Energy Technology Data Exchange (ETDEWEB)

    Dunkelmann, S.; Rudolph, F.; Prillwitz, A.; Groth, P.; Schuemichen, C. [Rostock Univ. (Germany). Klinik und Poliklinik fuer Nuklearmedizin

    1998-01-01

    Aim: To examine all cases with Graves` disease after radioiodine therapy of autonomously functioning thyroid tissue (AFFT) in order to find the cause. Methods: We retrospectively studied 1428 pts who were treated between 11/93 and 3/97 with radioiodine for AFTT and who underwent at least one control examination. Results: 15 (1.1%) of all pts developed Graves` disease 8.4 (4-13) months after radioiodine therapy. There was no direct suggestion of Graves` disease (TRAK negative, no endocrine ophthalmopathy) in any pt at the time of radioiodine therapy. More detailed analysis of anamnestic data, however, revealed evidence that immunothyropathy predated radioiodine therapy in 11 of the 15 pts. Paradoxical effects of radioiodine therapy manifested as an increase in immunothyropathy 14 pts, a deterioration in metabolism in 11 pts and a first occurrence of endocrine ophthalmopathy in 5 pts. Conclusion: Exacerbation of preexisting, functional primarily insignificant immunothyropathia is held responsible in most cases for the observed paradoxical effects after radioiodine therapy, resulting in radiation-induced manifest Graves` disease; however no therapeutical consequences are recommended. (orig.) [Deutsch] Ziel: Erfassung von Pat. mit einer nach Radiojodtherapie wegen einer funktionellen Autonomie aufgetretenen Immunhyperthyreose sowie deren Ursachen. Methoden: Wir untersuchten in einer retrospektiven Studie 1428 Pat., die im Zeitraum 11/93 bis 3/97 wegen einer funktionellen Autonomie mit Radiojod behandelt wurden und die sich mindestens einer Kontrolluntersuchung unterzogen hatten. Ergebnisse: 15 (1,1%) der Pat. entwickelten 8,4 (4-13) Monate nach Radiojodtherapie eine postradiogene Immunhyperthyreose. Bei allen 15 Pat. lag zum Zeitpunkt der Radiojodtherapie kein direkter Hinweis auf eine Immunhyperthyreose vor (TRAK neg., keine endokrine Orbitopathie). Bei einer genauen Analyse anamnestischer Daten fanden sich jedoch bei 11 der 15 Pat. erste Hinweise auf das Vorliegen

  13. Wirksamkeit und Verträglichkeit von Mepartricin (Iperplasin® bei benigner Prostatahyperplasie: Ergebnisse eine Anwendungsbeobachtung

    Directory of Open Access Journals (Sweden)

    Madersbacher H

    2000-01-01

    Full Text Available Ziel der Studie: Das Ziel dieser Anwendungsbeobachtung war es, Wirksamkeit und Verträglichkeit von Mepartricin-Filmtabletten (Iperplasin® bei der Behandlung von Patienten mit benigner Prostatahyperplasie (BPH bzw. Prostatavergrößerung (BPE zu untersuchen. Patienten und Methoden: Im Rahmen einer österreichweiten Anwendungsbeobachtung wurden Patienten mit unterer Harntraktsymptomatik (LUTS, verursacht durch eine BPH/BPE, untersucht. Die wichtigsten Einschlußkriterien waren eine reduzierte maximale Harnflußrate (Qmax von 6-15 ml/sec und ein Restharn 100 ml. Als Studienmedikation erhielten die Patienten 3 x 1 Tbl. Iperplasin®. Ein, drei und sechs Monate nach Studienbeginn wurden die Patienten nachkontrolliert. Die wichtigsten Zielparameter waren eine Verbesserung des Internationalen Prostata Symptomen Scores (IPSS, der Lebensqualitätsfrage des IPSS (IPSS-Ql sowie des Qmax. Ein Einfluß auf die Sexualität wurde anhand des GRISS-Scores erhoben. Ergebnisse: Insgesamt wurden 130 Patienten (67,4 ± 8,4 Jahre; Durchschnitt ± Standardabweichung in diese Studie aufgenommen. Der IPSS sank von 16,4 ± 5,0 zu Studienbeginn auf 9,4 ± 6,0 (-41 %; p 0,0001 nach 6 Monaten Therapie, der IPSS-Ql von 3,3 ± 0,8 auf 2,0 ± 1,1 (-39 %; p 0,0001. Im gleichen Zeitraum stieg der Qmax von 11,3 ± 6,0 auf 12,5 ± 6,4 ml/sec (+11 %; p 0,0001, der Restharn sank von 49 ± 36 ml auf 33 ± 35 ml (-33 %; p 0,0001. Insgesamt war die Therapie mit Iperplasin® gut verträglich, bei 10 % traten im Rahmen der Studie unerwünschte Ereignisse oder interkurrente Erkrankungen auf, bei zwei Patienten mußte eine TURP durchgeführt werden. Der GRISS-Score blieb über den gesamten Studienzeitraum konstant. Schlußfolgerung: Diese Anwendungsbeobachtung belegt die Sicherheit von Iperplasin® bei Patienten mit LUTS und BPH/BPE, vor allem kommt zu keiner Beeinträchtigung der Vita sexualis. Obwohl eine signifikante Verbesserung von subjektiven und objektiven Parametern in dieser

  14. MRI in cardiac sarcoidosis and amyloidosis; MRT bei kardialer Sarkoidose und Amyloidose

    Energy Technology Data Exchange (ETDEWEB)

    Bauner, K.U. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Campus Grosshadern, Institut fuer Klinische Radiologie, Muenchen (Germany); Wintersperger, B. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Campus Grosshadern, Institut fuer Klinische Radiologie, Muenchen (Germany); University of Toronto, Department of Medical Imaging, Toronto General Hospital, Toronto, ON (Canada)

    2013-01-15

    Sarcoidosis and amyloidosis are both multisystem disorders, which may involve the heart; however, isolated cardiac disease is rare. Diagnosis of cardiac sarcoidosis and amyloidosis is crucial because the patient prognosis is dependent on cardiac involvement and early treatment. Echocardiography is the first line imaging modality in the diagnostic work-up of both diseases, possibly giving hints towards the correct diagnosis. Besides myocardial biopsy and radionuclide studies cardiac magnetic resonance imaging (MRI) is routinely performed in patients suspect of having infiltrative cardiomyopathy. The T1 mapping procedure is currently being evaluated as a new technique for detection and quantification of global myocardial enhancement, as seen in cardiac amyloidosis. Sensitivities and specificities for detection of cardiac sarcoidosis and amyloidosis can be significantly improved by MRI, especially with late gadolinium enhancement (LGE) imaging. In cardiac sarcoidosis the use of LGE is outcome-related while in amyloidosis analysis of T1-mapping may be of prognostic value. If cardiac involvement in sarcoidosis or amyloidosis is suspected cardiac MRI including LGE should be performed for establishing the diagnosis. (orig.) [German] Die Sarkoidose und Amyloidose sind Multisystemerkrankungen, in deren Verlauf es zu einer kardialen Beteiligung kommen kann. Bildgebend wird als primaeres Verfahren die Echokardiographie eingesetzt. Zur weiteren Diagnostik wird neben der Biopsie und nuklearmedizinischen Verfahren v. a. die MRT herangezogen. Als neuere Technik zur Darstellung globaler diffuser Kontrastmittelanreicherungen, wie sie im Rahmen der Amyloidose vorkommen, wird z. Z. das T1-Mapping evaluiert. Durch den Einsatz der MRT, insbesondere des Late-Gadolinium-Enhancements (LGE), koennen die Sensitivitaet und Spezifitaet in der Diagnostik der kardialen Sarkoidose und Amyloidose entscheidend verbessert werden. Bei der Sarkoidose stellt das Vorhandensein eines LGE einen

  15. Somatostatin receptor scintigraphy in endocrine ophthalmopathy; Somatostatin-Rezeptor-Szintigraphie bei endokriner Orbitopathie

    Energy Technology Data Exchange (ETDEWEB)

    Diaz, M. [Klinik und Poliklinik fuer Nuklearmedizin, Univ. Mainz (Germany); Kahaly, G. [3. Medizinische Klinik und Poliklinik, Innere Medizin - Endokrinologie, Univ. Mainz (Germany); Muehlbach, A. [3. Medizinische Klinik und Poliklinik, Innere Medizin - Endokrinologie, Univ. Mainz (Germany); Bockisch, A. [Klinik und Poliklinik fuer Nuklearmedizin, Univ. Mainz (Germany); Beyer, J. [3. Medizinische Klinik und Poliklinik, Innere Medizin - Endokrinologie, Univ. Mainz (Germany); Hahn, K. [Klinik und Poliklinik fuer Nuklearmedizin, Univ. Mainz (Germany)

    1994-12-01

    Somatostatin receptor scintigraphy with {sup 111}In-labeled octreotide proves to be a very sensitive diagnostic tool for evaluation of inflammative activity in endocrine ophthalmopathy (EO). The results of somatostatin receptor scintigraphy (SRS) in 40 patients with EO show a high orbital accumulation of {sup 111}In-octreotide in clinically active EO (4h-median/orbit-brain-ratio: 12.6; controls 4h-median: 5.8) Patients with clinically inactive EO (4h-median: 7.1) show a similar orbital accumulation of radioactivity compared to controls. 5 patients with active orbital myositis also revealed an even higher orbital accumulation of radioactivity (4h-median: 42.3). The diagnostic value of SRS lies in its ability to act as a measure of inflammation and an be useful as an activity parameter when planning therapeutic procedure as well as for EO follow-up. The results in patients with orbital myositis nevertheless do not permit a differential diagnosis with this method. The therapeutic value of {sup 111}In-octreotide in Graves` disease has yet to be established. (orig.) [Deutsch] Die Somatostatin-Rezeptor-Szintigraphie (SRS) mit dem {sup 111}Indium-markierten Somatostatinanalogon Octreotid stellt ein sensitives Verfahren zur Einschaetzung der entzuendlichen Aktivitaet bei endokriner Orbitopathie (EO) dar. Die Untersuchungen an 40 Patienten mit EO ergaben eine im Vergleich zur Kontrollgruppe signifikant hoehere orbitale Octreotidanreicherung bei klinisch aktiver Erkrankung (4h-Median/Orbita-Hirn-Quotient: 12,6; Kontrollgruppe 4h-Median: 5,8; p=0,0032). Patienten mit klinisch nicht aktiver Erkrankung (4h-Median: 7,1) unterschieden sich bezueglich der orbitalen Octreotidanreicherung nicht wesentlich von der Kontrollgruppe. Auch 5 Patienten mit florider orbitaler Myositis zeigten eine deutlich gesteigerte orbitale Aktivitaetsanreicherung (4h-Median: 42,3). Der diagnostische Nutzen der SRS liegt somit in ihrer Eigenschaft als Aktivitaets- und Entzuendungsparameter und kann mit

  16. Prediction of Exploration Target Areas for GEM Deposits in Mogok Stone Tract, Northern Myanmar by Integrating Remote Sensing and Geoscience Data

    Science.gov (United States)

    Oo, Tin Ko

    2011-07-01

    The Mogok Stone Tract area has long been known for world famous finest ruby since 1597. The Mogok area lies in northern Myanmar and is located at about 205.99km northeast from Mandalay, the second largest city of Myanmar. The Mogok Group of metasedimentary rocks is divided into four units: (1) Wabyudaung Marble, (2) Ayenyeinchantha Calc-silicate, (3) Gwebin Quartzite, and (4) Kabe Gneiss. Igneous rocks in the Mogok area are classified into two units: (1) Kabaing Granite and (2) Pingutaung Leucogranite. The Mogok area has a complex structure involving several folds and faults. Using marbles and calc-silicates as marker horizons, a series of anticline and syncline can be identified such as Mogok syncline, Ongaing anticline, Bawpadan syncline, and Kyatpyin anticline. All the foldings show a low-angle plunge to the south. The main precious stones of the Mogok area are ruby and sapphire; and the other important semi-precious stones are spinel, topaz, peridot, garnet, apatite, beryl, tourmaline (rubellite), quartz, diopside, fluorite, and enstatite. Geological and remote sensing data are processed to extract the indicative features of gem mineralized areas: lithology, structure, and hydrothermal alteration. Density slice version of Landsat ETM band ratios 5/7 is used to map clay alterations. Filtering Landsat ETM band 5 by using edge detection filter is applied for lineament mapping. Spatial integration of various geoscience and remote sensing data sets such as geological maps, Landsat ETM images, and the location map of gem mines show the distribution of alteration zones associated with the gem mineralization in the study area. Geographic Information System (GIS) model has been designed and implemented by ARCVIEW software package based on the overlay of lithologic, lineament, and alteration vector maps. This process has resulted in delineation of most promising areas of probable gem mineralized zones as on the output map.

  17. PET in patients with clear-cut multiple chemical sensitivity (MCS); PET bei Patienten mit klar definierter multipler chemischer Sensibilitaet (MCS)

    Energy Technology Data Exchange (ETDEWEB)

    Bornschein, S. [Toxikologische Abt. der II. Medizinischen Klinik und Poliklinik der Technischen Univ. Muenchen, Klinikum rechts der Isar, Muenchen (Germany); Klinik und Poliklinik fuer Psychiatrie und Psychotherapie der Technischen Univ. Muenchen, Klinikum rechts der Isar, Muenchen (Germany); Hausteiner, C.; Foerstl, H. [Klinik und Poliklinik fuer Psychiatrie und Psychotherapie der Technischen Univ. Muenchen, Klinikum rechts der Isar, Muenchen (Germany); Drzezga, A.; Schwaiger, M. [Nuklearmedizinische Klinik und Poliklinik der Technischen Univ. Muenchen, Klinikum rechts der Isar, Muenchen (Germany); Bartenstein, P. [Klinik und Poliklinik fuer Nuklearmedizin, Universitaetsklinikum Mainz (Germany); Zilker, Th. [Toxikologische Abt. der II. Medizinischen Klinik und Poliklinik der Technischen Univ. Muenchen, Klinikum rechts der Isar, Muenchen (Germany)

    2002-12-01

    Aim: Multiple chemical sensitivity (MCS) is a controversially discussed symptom complex. Patients afflicted by MCS react to very low and generally non-toxic concentrations of environmental chemicals. It has been suggested that MCS leads to neurotoxic damage or neuroimmunological alteration in the brain detectable by positron emission tomography (PET) and single photon emission computer tomography (SPECT). These methods are often applied to MCS patients for diagnosis, although they never proved appropriate. Method: We scanned 12 MCS patients with PET, hypothesizing that it would reveal abnormal findings. Results: Mild glucose hypometabolism was present in one patient. In comparison with normal controls, the patient group showed no significant functional brain changes. Conclusion: This first systematic PET study in MCS patients revealed no hint of neurotoxic or neuroimmunological brain changes of functional significance. (orig.) [German] Ziel: Multiple chemische sensibilitaet (MCS) ist ein umstrittenes Krankheitsbild, das durch Reaktionen auf geringe, fueer Normalpersonen unschaedliche Mengen an Umweltchemikalien gekennzeichnet ist. Es wurde postuliert, dass MCS zu neurotoxischer Schaedigung bzw. neuroimmunologischer Veraenderung im Gehirn fuehrt, die mittels funktioneller bildgebender Verfahren, z. B. positronenemissionstomographie (PET), single-photon-emissions-computer-tomographie (SPECT) dargestellt werden koennte. Obwohl hierfuer kein wissenschaftlicher Beleg erbracht wurde, werden diese Methoden vielfach diagnostisch bei MCS-Patienten eingesetzt. Methode: Wir untersuchten 12 MCS-Patienten mit PET, um etwaige funktionelle Hirnveraenderungen nachzuweisen. Ergebnisse: Im Einzelvergleich war bei einem Patienten ein diskreter Glukose-Hypometabolismus in einzelnen Hirnregionen vorhanden. Im Gruppenvergleich konnte keine signifikante Abweichung von der Norm gefunden werden. Schlussfolgerung: Diese erste systematische PET-Studie bei MCS-Patienten erbrachte keinen

  18. GEM 10B Satellite gravity data and Nigerian oil prospects

    International Nuclear Information System (INIS)

    Garde, S.C.; Kim, W.Y.

    1984-11-01

    Extension of the hydrocarbon rich Benue depression and the Niger delta basin in the bight of Benin is construed from the gravity data of Gravity Earth Model (GEM) 10B Satellite, published by NASA, Godard Space Flight Centre in 1977. This interpretation is based on the supposition that: i) the depth of a buried horizontal cylinder can be estimated by the Fourier transform of the vertical gravity field [Odegard and Berg, Geophys., 30, No. 3, 424-438 (1965)]; and ii) the oil horizons of southern Nigeria are basically connected to the separation of South American and African plates [Burke et al., African Geology, Ibadan Univ. Press, Ibadan, Nigeria, p. 187-204 (1970)]. (author)

  19. Girls in Engineering, Mathematics and Science, GEMS: A Science Outreach Program for Middle-School Female Students

    Science.gov (United States)

    Dubetz, Terry A.; Wilson, Jo Ann

    2013-01-01

    Girls in Engineering, Mathematics and Science (GEMS) is a science and math outreach program for middle-school female students. The program was developed to encourage interest in math and science in female students at an early age. Increased scientific familiarity may encourage girls to consider careers in science and mathematics and will also help…

  20. Using simulated maps to interpret the geochemistry, formation and quality of the Blue Gem Coal Bed, Kentucky, USA

    Science.gov (United States)

    Geboy, Nicholas J.; Olea, Ricardo A.; Engle, Mark A.; Martin-Fernandez, Jose Antonio

    2013-01-01

    This study presents geostatistical simulations of coal-quality parameters, major oxides and trace metals for an area covering roughly 812 km2 of the Blue Gem coal bed in southeastern Kentucky, USA. The Blue Gem, characterized by low ash yield and low sulfur content, is an important economic resource. Past studies have characterized the Blue Gem's geochemistry, palynology and petrography and inferred a depositional setting of a planar peat deposit that transitioned to slightly domed later in its development. These studies have focused primarily on vertical geochemical trends within the coal bed. Simulated maps of chemical elements derived from 45 measured sample locations across the study area provide an opportunity to observe changes in the horizontal direction within the coal bed. As the Blue Gem coal bed shows significant vertical chemical trends, care was taken in this study to try to select samples from a single, middle portion of the coal. By revealing spatial distribution patterns of elements across the middle of the bed, associations between different components of the coal can be seen. The maps therefore help to provide a picture of the coal-forming peat bog at an instant in geologic time and allow interpretation of a depositional setting in the horizontal direction. Results from this middle portion of the coal suggest an association of SiO2 with both K2O and TiO2 in different parts of the study area. Further, a pocket in the southeast of the study area shows elevated concentrations of elements attributable to observed carbonate-phase minerals (MgO, CaO, Ba and Sr) as well as elements commonly associated with sulfide-phase minerals (Cu, Mo and Ni). Areas of relatively high ash yield are observed in the north and south of the mapped area, in contrast to the low ash yields seen towards the east. Additionally, we present joint probability maps where multiple coal-quality parameters are plotted simultaneously on one figure. This application allows researchers

  1. Shortcomings of the industrial quality assurance of {sup 106}Ru ophthalmic plaques; Therapierelevante Schwachstellen bei der industriellen Qualitaetssicherung von {sup 106}Ru-Augenapplikatoren

    Energy Technology Data Exchange (ETDEWEB)

    Kaulich, T.W.; Nuesslin, F. [Universitaetsklinik fuer Radioonkologie, Tuebingen (Germany). Abt. Medizinische Physik; Zurheide, J. [BrainLAB AG, Heimstetten (Germany); Fluehs, D. [Abt. Strahlentherapie, Bereich klinische Strahlenphysik, Universitaetsklinikum Essen (Germany); Haug, T. [Isotopenlabor der Univ. Tuebingen (Germany); Bamberg, M. [Abt. Radioonkologie, Universitaetsklinik fuer Radioonkologie, Tuebingen (Germany)

    2001-11-01

    Background: Beta emitting {sup 106}Ru applicators manufactured by Bebig GmbH (Berlin, Germany) are widely used to treat intraocular tumors. The applicators are fixed to the bulbus and removed after several days. The following therapy relevant defects have been detected by an internal clinical acceptance test: risk of leakage and inconsistent dose-rate specifications by the manufacturer. In the meantime, components of the internal clinical acceptance test have been adopted successfully by the manufacturer of the {sup 106}Ru ophthalmic plaques. Material and Method: {sup 106}Ru ophthalmic plaques were tested with the following internal clinical acceptance tests: visual inspection, surface contamination, leakage, and dose-rate verification. The surface contamination test consists of a wet wipe test at moderate pressure. For the leakage test of the {sup 106}Ru ophthalmic plaques a clinically relevant scenario was developed in which the contact of the applicator with human tissue is simulated. In the course of it the applicator is inserted into Ringer's solution for several days. The certified energy dose-rate statements of the manufacturer are examined with a 1 mm{sup 3} plastic scintillator for consistency. (orig.) [German] Hintergrund: {sup 106}Ru-Augenapplikatoren der Fa. Bebig (Berlin) werden zur strahlentherapeutischen Behandlung von intraokularen Tumoren eingesetzt. Die Applikatoren werden sklerakontaktierend am Bulbus fixiert und nach mehreren Tagen wieder entfernt. Durch eine klinikinterne Eingangspruefung wurden folgende therapierelevante Maengel bei den Augenapplikatoren entdeckt: mangelhafte Dichtheit und inkonsistente Dosisleistungsangaben des Herstellers. Ein Teil dieser klinikinternen Eingangspruefung wurde inzwischen vom Hersteller der {sup 106}Ru-Augenapplikatoren uebernommen und erfolgreich eingesetzt. Material und Methode: Es wurden {sup 106}Ru-Augenapplikatoren durch folgende klinikinterne Eingangspruefungen getestet: optische Inspektion

  2. Determinanten der beruflichen Belastung bei jungen Lehrerinnen und Lehrern: Eine Längsschnittstudie

    OpenAIRE

    Candova, Antonia

    2005-01-01

    In der vorliegenden Arbeit wird geprüft, ob berufliche Belastung bei jungen Lehrerinnen und Lehrern von Personenmerkmalen (Top-down-Ansatz), Umweltmerkmalen (Bottom-up-Ansatz) und/oder der Interaktion zwischen Merkmalen der Person und Situation beeinflusst wird. Die Daten stammen aus der prospektiven Längsschnittsstudie "Berufsverläufe in der Mathematik", die sich mit der beruflichen Entwicklung von Mathematikabsolvierenden (Diplom und Lehramt) befasst. Hier werden Daten von 266 aktuell beruf...

  3. Empathy and Facial Expression Recognition in Children With and Without Attention-Deficit/Hyperactivity Disorder: Effects of Stimulant Medication on Empathic Skills in Children with Attention-Deficit/Hyperactivity Disorder.

    Science.gov (United States)

    Gumustas, Funda; Yilmaz, Ibrahim; Yulaf, Yasemin; Gokce, Sebla; Sabuncuoglu, Osman

    2017-06-01

    The aim of this study was to compare children and adolescents with attention-deficit/hyperactivity disorder (ADHD) to healthy children and adolescents in terms of state and trait empathy and emotion expression recognition skills. The goal was also to determine whether there are changes in emotion recognition and empathy measures in children with ADHD after methylphenidate (MPH) treatment. The research sample consisted of outpatient drug-naive children and adolescents between the age of 8 and 14 years (n = 65) with ADHD according to the Diagnostic and Statistical Manual of Mental Disorders, 4th ed. criteria, and healthy children and adolescents of the same age (n = 61). Scores of the oppositional problems (OPs) and conduct problems (CPs) were obtained to evaluate their impact on children's empathy skills with the Child Behavior Checklist. Self-reported (Bryant Index of Empathy, BEI) and parent-reported (Griffith Empathy Measurement-Parent Rating, GEM-PR) scales were used to evaluate trait empathy. The Empathy Response Task (ERT) was used to evaluate state empathy, and the Diagnostic Analysis of Nonverbal Accuracy-2 (DANVA-2) was used to evaluate facial expression recognition skills. The scales and tests were repeated after 12 weeks of MPH treatment in the ADHD group. There were no significant statistical differences in trait empathy skills evaluated by parent-reported and self-reported measures, ERT, and DANVA-2 scores. In self-reported measures, the girls had higher scores than boys. From the results of the regression analysis, it was concluded that OPs were not associated with the measures. However, CPs were associated with the scores of the BEI, GEM-PR, and the match scores of the ERT. The average dosage of MPH in the group with ADHD was 0.83 ± 0.21 mg/(kg·d). While there was no change in the BEI and GEM-PR scores after 12 weeks of treatment, there was a significant increase in the ERT interpretation subscore and a significant decrease in the

  4. Performance studies of the P barANDA planar GEM-tracking detector in physics simulations

    Science.gov (United States)

    Divani Veis, Nazila; Firoozabadi, Mohammad M.; Karabowicz, Radoslaw; Maas, Frank; Saito, Takehiko R.; Voss, Bernd; ̅PANDA Gem-Tracker Subgroup

    2018-03-01

    The P barANDA experiment will be installed at the future facility for antiproton and ion research (FAIR) in Darmstadt, Germany, to study events from the annihilation of protons and antiprotons. The P barANDA detectors can cover a wide physics program about baryon spectroscopy and nucleon structure as well as the study of hadrons and hypernuclear physics including the study of excited hyperon states. One very specific feature of most hyperon ground states is the long decay length of several centimeters in the forward direction. The central tracking detectors of the P barANDA setup are not sufficiently optimized for these long decay lengths. Therefore, using a set of the planar GEM-tracking detectors in the forward region of interest can improve the results in the hyperon physics-benchmark channel. The current conceptual designed P barANDA GEM-tracking stations contribute the measurement of the particles emitted in the polar angles between about 2 to 22 degrees. For this designed detector performance and acceptance, studies have been performed using one of the important hyperonic decay channel p bar p → Λ bar Λ → p bar pπ+π- in physics simulations. The simulations were carried out using the PandaRoot software packages based on the FairRoot framework.

  5. MRI in dementia-type diseases; MRT bei demenziellen Erkrankungen

    Energy Technology Data Exchange (ETDEWEB)

    Bodea, S.V.; Muehl-Benninghaus, R. [Universitaetsklinikum des Saarlandes, Klinik fuer Diagnostische und Interventionelle Neuroradiologie, Homburg (Germany)

    2015-05-01

    Dementia-inducing conditions represent a leading cause of disability and are a major health concern in industrialized countries. The burden these conditions put on society is certain to rise in the context of an ever-increasing elderly population. As these conditions feature an insidious onset and overlapping clinical features, imaging is a powerful tool in refining the diagnosis and assessing the progression of dementing conditions. The radiologist needs to be aware of and be able to detect underlying pathologies which could be reversible. Furthermore, imaging is important not only in excluding other pathologies but also in improving diagnostic accuracy. This article presents the typical clinical presentations as well as magnetic resonance imaging (MRI) features of the degenerative and the non-degenerative causes of dementia. The focus is on the core knowledge for MRI diagnostics in dementing conditions and a brief presentation of the latest MRI techniques which may become a part of standard imaging protocols in the future. (orig.) [German] Demenzielle Erkrankungen gehoeren in den Industrielaendern zu den haeufigsten Ursachen fuer Beeintraechtigungen im Alltag. Durch eine stetig alternde Population nimmt auch die Belastung fuer die Gesellschaft immer weiter zu. Bei haeufig schleichendem Symptombeginn sowie sich ueberlappender Klinik mit anderen Krankeitsbildern kann die Bildgebung ein gutes Werkzeug zur Praezisierung der Diagnose und Beurteilung eines Progresses sein. Der Radiologe sollte andere und reversible Pathologien erkennen und von demenztypischen Veraenderungen abgrenzen koennen. Dieser Artikel beschreibt typische klinische Symptome und auch bildmorphologische Veraenderungen verschiedener Demenzformen, die durch neurodegenerative und nichtdegenerative Ursachen bedingt sein koennen. Ausserdem werden aktuellste MRT-Techniken vorgestellt. Diese koennten kuenftig im Standartprotokoll zur Bildgebung bei der Abklaerung demenzieller Syndrome verankert sein. (orig.)

  6. ESTADO DE LA EDUCACIÓN Y FORMACIÓN EMPRESARIAL EN LOS PAÍSES Y REGIONES ESPAÑOLAS DEL GEM

    Directory of Open Access Journals (Sweden)

    Ana Fernández Laviada

    2014-12-01

    Full Text Available Specialised literature presents education and training as a determining factor for entrepreneurship. However, time and time again experts at the Global Entrepreneurship Monitor (GEM have stated that it’s one lowest, and sometimes the least, valued elements in this area. Therefore, the objective of this study is to analyse the state of entrepreneurship education and training in its different stages within the countries and regions that participated in GEM 2012. Specifically, what is sought is, based on the opinion of the experts, the state of entrepreneurship training and education in each level analysed in GEM, generically as well as by country, while looking at the possible differences (strengths and weaknesses that appear in each one. Furthermore, this is paired with a national analysis that examines the situation of the different participating regions in the study. In order to carry out the analysis, the 2012 NES database is used. In that edition, a total of 69 countries participated and, in the case of Spain, there were 14 regions all with 36 experts in each. The data processing is carried out using the Rasch model for measurement. The preliminary results show that, in general, university level education geared towards entrepreneurship is more highly developed than at the lower levels of education, such as in secondary and primary education. Nevertheless, the individual analysis makes it possible to detect differences between countries and regions.

  7. MR volumetry of the trigeminal nerve in patients with unilateral facial pain; MR-Volumetrie des N. trigeminus bei Patienten mit einseitigen Gesichtsschmerzen

    Energy Technology Data Exchange (ETDEWEB)

    Kress, B.; Fiebach, J.; Sartor, K.; Stippich, C. [Abt. Neuroradiologie, Neurologische Klinik, Universitaetsklinikum Heidelberg (Germany); Rasche, D.; Tronnier, V. [Neurochirurgische Klinik, Universitaetsklinikum Heidelberg (Germany)

    2004-05-01

    Purpose: to assess whether MRI can detect atrophy of the trigeminal nerve in patients with trigeminal neuralgia. Materials and methods: a prospective MRI study was conducted in 39 patients (trigeminal neuralgia, trigeminal neuropathy, or atypical facial pain) and 25 volunteers. Using a coronal orientation (T1 flash 3D; T2 CISS 3D), regions of interest were delineated in the cisternal part of the trigeminal nerve along the border of the nerve to calculate the volume of the nerve. The volume of the nerve was compared side-by-side in each patient (t-test, p < 0.05) and the volume difference compared between patients and volunteers. Results: the volume of the compromised trigeminal nerve in patients with trigeminal neuralgia was lower than on the contralateral healthy side, with the difference between healthy and compromised side statistically significant (p < 0.05). In all other patients and in all volunteers, no significant difference was found between the volume of the healthy and compromised nerve. The volume difference between the healthy and compromised side in patients with trigeminal neuralgia was significantly higher (p < 0.05) than in all other patients and volunteers. Conclusion: atrophy of the trigeminal nerve caused by a nerve-vessel conflict can be detected by MRI. Only patients with trigeminal neuralgia show this unilateral atrophy. Therefore, it is possible to demonstrate the result of the nerve-vessel conflict and to determine the consequences of such a conflict. (orig.) [German] Ziel: Die Studie wurde mit der Frage durchgefuehrt, ob die bei Patienten mit Trigeminusneuralgie durch einen Gefaess-Nerven-Konflikt bedingte Atrophie des Nervs magnetresonanztomographisch darstellbar ist. Methodik: 39 Patienten (Trigeminusneuralgie, Trigeminusneuropathie, atypischer Gesichtsschmerz) und 25 Probanden wurden prospektiv magnetresonanztomographisch untersucht. In koronaren T1- und T2-Gradientenechosequenzen wurde der zisternale Abschnitt des N. trigeminus mittels

  8. Prospektive Entwicklung des postoperativen Sprachverstehens nach Tympanoplastik bei chronischer Otitis media

    OpenAIRE

    Knof, B; Plotz, K; Krack, A; Stumper, J; Schönfeld, R

    2013-01-01

    Einleitung: Tympanoplastiken I/III bei chron. Otitis media COM (mesotympanalis CMOM und epitympanalis CEOM). In der Literatur werden erfolgreiche operative Behandlungen mit Verringerung der Schallleitungskomponente (air-bone gap) belegt (Gierke et al. 2011). Aus Sicht des Patienten steht die Verbesserung des Hörvermögens und des Sprachverstehens im Alltag im Vordergrund. Das Ziel war die Untersuchung der Entwicklung des Hörvermögens in Ruhe sowie im Störgeräusch.Methoden: An den Hör- und Sp...

  9. Triple GEM gas detectors as real time fast neutron beam monitors for spallation neutron sources

    International Nuclear Information System (INIS)

    Murtas, F; Claps, G; Croci, G; Tardocchi, M; Pietropaolo, A; Cippo, E Perelli; Rebai, M; Gorini, G; Frost, C D; Raspino, D; Rhodes, N J; Schooneveld, E M

    2012-01-01

    A fast neutron beam monitor based on a triple Gas Electron Multiplier (GEM) detector was developed and tested for the ISIS spallation neutron source in U.K. The test on beam was performed at the VESUVIO beam line operating at ISIS. The 2D fast neutron beam footprint was recorded in real time with a spatial resolution of a few millimeters thanks to the patterned detector readout.

  10. Formation of benzo[f]-1-indanone frameworks by regulable intramolecular annulations of gem-dialkylthio trienynes.

    Science.gov (United States)

    Fang, Zhongxue; Liu, Ying; Barry, Badru-Deen; Liao, Peiqiu; Bi, Xihe

    2015-02-20

    An atom-economic route to benzo[f]-1-indanone frameworks has been developed starting from the readily available gem-dialkylthio trienynes by intramolecular annulations. The chemoselectivity of the intramolecular cyclizations can be regulated by both the base and the type of gas atmosphere used in the reaction, thus allowing the divergent synthesis of the corresponding functionalized benzo[f]-1-indanones in good to excellent yields.

  11. CONTROLE GERENCIAL: UMA ANÁLISE NAS EMPRESAS CONTÁBEIS DA CIDADE DE CAICÓ/RN.

    Directory of Open Access Journals (Sweden)

    Hugo Azevedo Rangel de Morais

    2016-07-01

    Full Text Available O controle gerencial de uma empresa é necessário para um eficiente desenvolvimento interno. Com as mudanças constantes das legislações e a evolução da tecnologia de informação nas empresas contábeis, é essencial o controle gerencial eficiente, através dele será possível identificar como está a vida da empresa no seu dia a dia. Neste trabalho é mostrada a importância do controle gerencial para as empresas contábeis, situada na cidade de Caicó/RN, demonstrando a sua importância para auxiliar nas tomadas de decisões. O presente estudo tem como objetivo geral de analisar se nas empresas contábeis da cidade de Caicó existe um controle gerencial que os auxiliem nas tomadas de decisões, verificando se existem a prestação de serviço de contabilidade gerencial e analisando a importância do controle gerencial para os empresários. A contextualização do tema trata-se de pesquisas bibliográficas. A metodologia desenvolvida na pesquisa é classificada como descritiva, do ponto de vista de sua natureza é uma pesquisa aplicada, tendo uma abordagem qualitativa por ter caráter exploratório, já no que se refere aos procedimentos técnicos trata-se de um levantamento. Observou que os empresários tem conhecimento em relação à importância do controle gerencial, a maioria coloca em pratica obtendo uma boa classificação dos controles com confiabilidade para auxiliar nas tomadas de decisões, foi detectado que a maioria das empresas faz um planejamento dos objetivos a serem controlados.

  12. Development of the GEM-MACH-FireWork System: An Air Quality Model with On-line Wildfire Emissions within the Canadian Operational Air Quality Forecast System

    Science.gov (United States)

    Pavlovic, Radenko; Chen, Jack; Beaulieu, Paul-Andre; Anselmp, David; Gravel, Sylvie; Moran, Mike; Menard, Sylvain; Davignon, Didier

    2014-05-01

    A wildfire emissions processing system has been developed to incorporate near-real-time emissions from wildfires and large prescribed burns into Environment Canada's real-time GEM-MACH air quality (AQ) forecast system. Since the GEM-MACH forecast domain covers Canada and most of the U.S.A., including Alaska, fire location information is needed for both of these large countries. During AQ model runs, emissions from individual fire sources are injected into elevated model layers based on plume-rise calculations and then transport and chemistry calculations are performed. This "on the fly" approach to the insertion of the fire emissions provides flexibility and efficiency since on-line meteorology is used and computational overhead in emissions pre-processing is reduced. GEM-MACH-FireWork, an experimental wildfire version of GEM-MACH, was run in real-time mode for the summers of 2012 and 2013 in parallel with the normal operational version. 48-hour forecasts were generated every 12 hours (at 00 and 12 UTC). Noticeable improvements in the AQ forecasts for PM2.5 were seen in numerous regions where fire activity was high. Case studies evaluating model performance for specific regions and computed objective scores will be included in this presentation. Using the lessons learned from the last two summers, Environment Canada will continue to work towards the goal of incorporating near-real-time intermittent wildfire emissions into the operational air quality forecast system.

  13. Application of the GEM Inventory Data Capture Tools for Dynamic Vulnerability Assessment and Recovery Modelling

    Science.gov (United States)

    Verrucci, Enrica; Bevington, John; Vicini, Alessandro

    2014-05-01

    A set of open-source tools to create building exposure datasets for seismic risk assessment was developed from 2010-13 by the Inventory Data Capture Tools (IDCT) Risk Global Component of the Global Earthquake Model (GEM). The tools were designed to integrate data derived from remotely-sensed imagery, statistically-sampled in-situ field data of buildings to generate per-building and regional exposure data. A number of software tools were created to aid the development of these data, including mobile data capture tools for in-field structural assessment, and the Spatial Inventory Data Developer (SIDD) for creating "mapping schemes" - statistically-inferred distributions of building stock applied to areas of homogeneous urban land use. These tools were made publically available in January 2014. Exemplar implementations in Europe and Central Asia during the IDCT project highlighted several potential application areas beyond the original scope of the project. These are investigated here. We describe and demonstrate how the GEM-IDCT suite can be used extensively within the framework proposed by the EC-FP7 project SENSUM (Framework to integrate Space-based and in-situ sENSing for dynamic vUlnerability and recovery Monitoring). Specifically, applications in the areas of 1) dynamic vulnerability assessment (pre-event), and 2) recovery monitoring and evaluation (post-event) are discussed. Strategies for using the IDC Tools for these purposes are discussed. The results demonstrate the benefits of using advanced technology tools for data capture, especially in a systematic fashion using the taxonomic standards set by GEM. Originally designed for seismic risk assessment, it is clear the IDCT tools have relevance for multi-hazard risk assessment. When combined with a suitable sampling framework and applied to multi-temporal recovery monitoring, data generated from the tools can reveal spatio-temporal patterns in the quality of recovery activities and resilience trends can be

  14. Depth of Response in Multiple Myeloma: A Pooled Analysis of Three PETHEMA/GEM Clinical Trials.

    Science.gov (United States)

    Lahuerta, Juan-Jose; Paiva, Bruno; Vidriales, Maria-Belen; Cordón, Lourdes; Cedena, Maria-Teresa; Puig, Noemi; Martinez-Lopez, Joaquin; Rosiñol, Laura; Gutierrez, Norma C; Martín-Ramos, María-Luisa; Oriol, Albert; Teruel, Ana-Isabel; Echeveste, María-Asunción; de Paz, Raquel; de Arriba, Felipe; Hernandez, Miguel T; Palomera, Luis; Martinez, Rafael; Martin, Alejandro; Alegre, Adrian; De la Rubia, Javier; Orfao, Alberto; Mateos, María-Victoria; Blade, Joan; San-Miguel, Jesus F

    2017-09-01

    Purpose To perform a critical analysis on the impact of depth of response in newly diagnosed multiple myeloma (MM). Patients and Methods Data were analyzed from 609 patients who were enrolled in the GEM (Grupo Español de Mieloma) 2000 and GEM2005MENOS65 studies for transplant-eligible MM and the GEM2010MAS65 clinical trial for elderly patients with MM who had minimal residual disease (MRD) assessments 9 months after study enrollment. Median follow-up of the series was 71 months. Results Achievement of complete remission (CR) in the absence of MRD negativity was not associated with prolonged progression-free survival (PFS) and overall survival (OS) compared with near-CR or partial response (median PFS, 27, 27, and 29 months, respectively; median OS, 59, 64, and 65 months, respectively). MRD-negative status was strongly associated with prolonged PFS (median, 63 months; P < .001) and OS (median not reached; P < .001) overall and in subgroups defined by prior transplantation, disease stage, and cytogenetics, with prognostic superiority of MRD negativity versus CR particularly evident in patients with high-risk cytogenetics. Accordingly, Harrell C statistics showed higher discrimination for both PFS and OS in Cox models that included MRD (as opposed to CR) for response assessment. Superior MRD-negative rates after different induction regimens anticipated prolonged PFS. Among 34 MRD-negative patients with MM and a phenotypic pattern of bone marrow involvement similar to monoclonal gammopathy of undetermined significance at diagnosis, the probability of "operational cure" was high; median PFS was 12 years, and the 10-year OS rate was 94%. Conclusion Our results demonstrate that MRD-negative status surpasses the prognostic value of CR achievement for PFS and OS across the disease spectrum, regardless of the type of treatment or patient risk group. MRD negativity should be considered as one of the most relevant end points for transplant-eligible and elderly fit patients

  15. Role of radiotherapy in age-related macular degeneration. A prospective study; Photonentherapie der subfovealen choroidalen Neovaskularisation bei altersabhaengiger Makuladegeneration. Ergebnisse einer prospektiven Studie an 40 Patienten

    Energy Technology Data Exchange (ETDEWEB)

    Prettenhofer, U.; Mayer, R.; Oechs, A.; Pakisch, B.; Stranzl, H.; Willfurth, P.; Hackl, A. [Univ. Graz (Austria). Abt. fuer Strahlentherapie; Haas, A. [Univ. Graz (Austria). Universitaets-Augenklinik

    1998-12-01

    Aim: To determine the effect of external beam radiotherapy on subfoveal choroidal neovascularization in age-related macular degeneration. Patients and methods: Between September 1995 and July 1996, 40 patients (9 males and 31 females; mean age 74 years, range 61 to 83 years) were included in a prospective study. Eight patients had classic, well defined neovascularisations, 32 patients had occult lesions. Complete ophthalmic investigations included visual acuity contrast sensitivity as well as fluorescein and indocyanine green angiographic examinations prior to treatment and 1, 3, 6, and 12 months after radiotherapy. External beam radiotherapy (8-MV photons) was delivered with a total dose of 14.4 Gy in 8 fractions of 1.8 Gy per day. The field size averaged 5.5x4.5 cm. Results: No treatment related morbidity during or after treatment was obtained. After 6 months follow-up the visual acuity was improved in 2 (5%) patients and maintained at pretreatment level in 17 (42%) patients. However, 12 months post treatment a stable situation was found in 6 (15%) patients and a decrease in visual acuity in 34 (85%) patients. The central visual fields deteriorated significantly from 16.5 decibel (dB) to 12.4 dB. The enlargement of exsudats and neovascular membranes increased 5- to 7-fold. At 12 months after treatment, 3 (7.5%) patients stated that they had improved vision subjectively, 12 (30%) patients had no change and 25 (62.5%) patients suffered from subjective decrease in visual acuity. Conclusions: Using a total dose of 14.4 Gy/1.8 Gy no difference concerning visual acuity and exsudative changes in comparison to the natural history on age-related macular degeneration was obtained after 12 months. However, the results of multicenter studies are to be awaited. (orig.) [Deutsch] Ziel: Ueberpruefung der Effektivitaet der Strahlentherapie als Therapieansatz in der Behandlung subfovealer choroidaler Neovaskularisation bei altersabhaengiger Makuladegeneration. Patienten und

  16. Development of the data acquisition system for the Triple-GEM detectors for the upgrade of the CMS forward muon spectrometer

    CERN Document Server

    Abbaneo, D; Akl, M A; Ahmed, W; Armaingaud, C; Aspell, P; Assran, Y; Bally, S; Ban, Y; Banerjee, S; Barria, P; Benussi, L; Bhopatkar, V; Bianco, S; Bos, J; Bouhali, O; Cai, J; Calabria, C; Castaneda, A; Cauwenbergh, S; Celik, A; Christiansen, J; Colafranceschi, S; Colaleo, A; Conde Garcia, A; Dabrowski, M; De Lentdecker, G; De Oliveira, R; De Robertis, G; Dildick, S; Ferry, S; Flanagan, W; Gilmore, J; Guilloux, F; Gutierrez, A; Hoepfner, K; Hohlmann, M; Kamon, T; Karchin, P E; Khotilovich, V; Korntheuer, M; Krutelyov, S; Lenzi, T; Loddo, F; Maerschalk, T; Magazzu, G; Maggi, M; Maghrbi, Y; Marchioro, A; Marinov, A; Mazumdar, N; Merlin, J A; Mukhopadhyay, S; Nuzzo, S; Oliveri, E; Philipps, B; Piccolo, D; Postema, H; Radi, A; Radogna, R; Raffone, G; Ranieri, A; Rodrigues, A; Ropelewski, L; Safonov, A; Sakharov, A; Salva, S; Saviano, G; Sharma, A; Talvitie, J; Tatarinov, A; Teng, H; Turini, N; Tuuva, T; Twigger, J; Tytgat, M; van Stenis, M.; Verhagen, E; Yang, Y; Zaganidis, N; Zenoni, F

    2014-01-01

    In this contribution we will report on the progress of thedesign of the readout and data acquisition system being developedfor triple-GEM detectors which will be installed in the forwardregion (1.5 < |η| < 2.2) of the CMS muonspectrometer during the 2nd long shutdown of the LHC, expectedin the period 2017–2018. The system will be designed to take fulladvantage of current generic developments introduced for the LHCupgrades. The current design is based on the use of CERN GLIB boardshosted in micro-TCA crates for the off-detector electronics and theVersatile Link with the GBT chipset to link the front-endelectronics to the GLIB boards. In this contribution we willdescribe the physics goals, the hardware architectures and report onthe expected performance of the CMS GEM readout system, includingpreliminary timing resolution simulations.

  17. Radiotherapy for treatment of bursitis. Indication, technique, own results, literature survey; Strahlentherapie bei der Periarthropathia humeroscapularis (PHS). Indikation, Technik, eigene Ergebnisse, Literaturuebersicht

    Energy Technology Data Exchange (ETDEWEB)

    Heyd, R. [Staedtische Kliniken Offenbach am Main (Germany). Strahlenklinik]|[Frankfurt Univ. (Germany). Klinik fuer Strahlentherapie und Onkologie; Schopohl, B.; Boettcher, H.D. [Frankfurt Univ. (Germany). Klinik fuer Strahlentherapie und Onkologie

    1998-12-31

    Our own experience covers 41 primarily chronic cases. The patients have been irradiated with a telecobalt device with isocentric opposing fields, receiving 4x1.0 Gy within two weeks; 15 patients (36.6%) received a second radiation treatment (8 Gy), and one patient (2.4%) a third (12 Gy). After a follow-up period of 44 months on the average, the results were: Complete remittence of pain in 44%, abatement of pain in 44%, and no effect in 12%. Improvement of shoulder joint motility was achieved in 78%. The rate of recidivation was as low as 3%. A statistical evaluation of data acquired revealed that the prognosis is worst in case of a long period of pain preceding commencement of radiotherapy, combined with intensive prior therapy. (orig./CB) [Deutsch] In einer eigenen Untersuchung wurden 41 ueberwiegend chronische Faelle mit 4x1,0 Gy in 2 Wochen an einem Telekobaltgeraet mit isozentrischen Gegenfeldern behandelt, 15 (36,6%) erhielten eine 2. Bestrahlungsserie (8 Gy), ein Fall (2,4%) eine Dritte (12 Gy). Nach einem Nachbeobachtungszeitraum von median 44 Monaten fand sich bei 44% eine komplette Schmerzremission, bei 44% eine Linderung und 12% waren ohne einen Einfluss der Behandlung. Eine Verbesserung der Motilitaet des Schultergelenkes wurde bei 78% erreicht. Die Rezidivrate lag bei nur 3%. Nach statistischer Bearbeitung der Daten erwies sich die Kombination einer langen Beschwerdedauer vor Einleitung der Radiotherapie und intensiver Vortherapie als prognostisch unguenstiger (p=0,02). (orig.)

  18. Technical and marketing aspects of power use in industry and trade; Technik- und Marketingaspekte bei der industriellen und gewerblichen Stromanwendung

    Energy Technology Data Exchange (ETDEWEB)

    Mann, E.W.; Duenkelberg, R.

    1997-02-01

    Using electric power permits energetic optimization of production processes in industry and trade. Because of the trend towards qualitatively high-grade products, the energy form electric power plays a key role. Increased power demand on the part of industrial customers coincides with increased competition in the energy supply sector at the national and international levels. Within short, therefore, these industrial customers may prompt a change in preferences at the supplier side. Utilities will adopt suitable marketing concepts in order to gain profile with their customers as service providers. Operating close to customers will essentially influence customer satisfaction and, thereby, customer loyalty. (orig./RHM) [Deutsch] Durch die Stromanwendung koennen Produktionsprozesse in Industrie und Gewerbe energetisch optimiert werden. Bei dem Trend zu qualitativ hochwertigen Produkten nimmt die Energieform Strom eine Schluesselstellung ein. Die erhoehte Stromnachfrage der Industriekunden trifft auf zunehmenden Wettbewerb bei der Energieversorgung auf nationaler und internationaler Ebene, wodurch in Kuerze Industriekunden andere Praeferenzen bei den Energielieferanten setzen koennen. Durch geeignete Marketingkonzepte werden sich die Energieversorgungsunternehmen (EVU) als Energiedienstleister ihrer Kunden profilieren. Die Naehe zum Kunden wird wesentlich die Kundenzufriedenheit und damit letztlich auch die Kundenloyalitaet beeinflussen. (orig./RHM)

  19. ARTROC—a readout ASIC for GEM-based full-field XRF imaging system

    Science.gov (United States)

    Fiutowski, T.; Koperny, S.; Łach, B.; Mindur, B.; Świentek, K.; Wiącek, P.; Dąbrowski, W.

    2017-12-01

    In the paper we report on development of an Application Specific Integrated Circuit (ASIC), called ARTROC, being part of a full-field X-ray fluorescence spectroscopy (XRF) imaging system equipped with a standard three stage Gas Electron Multiplier (GEM) detector of 10×10 cm2 area. The ARTROC consists of 64 independent channels, allowing for simultaneous recording of the amplitudes (energy sub-channel) and time stamps (timing sub-channel) of incoming signals. Thanks to the implemented token-based read out of derandomizing buffers, the ASIC also provides data sparsification and full zero suppression. Reconstruction of the hit positions is performed in an external data acquisition system by matching the time stamps of signals recorded in X- and Y-strips. The amplitude information is used for centre of gravity finding in clusters of signals on neighbouring strips belonging to the same detection events. The ASIC could work in one of six gain modes and one of two speed modes. In a slower mode the maximum count rate per channel is 105/s while in a faster mode it is three times higher. The ARTROC comprises also input protection circuits against possible random discharges inside active detector volume, so it can be used without any additional input components. The ASIC has been designed in 350 nm CMOS process. The basic functionality and parameters have been evaluated using the testability functions implemented in the ASIC design. The ASIC has been also tested in a fully equipped GEM detector set-up with X-rays source.

  20. Beckenbodenbeschwerden bei Fahrradfahrerinnen und mögliche Therapieansätze

    Directory of Open Access Journals (Sweden)

    Lyatoshinsky P

    2016-01-01

    Full Text Available Einleitung und Hypothese: Fahrradfahren ist nicht nur ein immer beliebter werdender Freizeitsport, sondern auch ein immer intensiver genutztes Fortbewegungsmittel. Somit ist es mittlerweile von großer Bedeutung, herauszufinden, welchen negativen Einfluss das Fahrradfahren auf den menschlichen Körper hat. Dieser Review fasst die aktuelle Evidenz zur Epidemiologie, Therapie und Prävention der Genital- und Beckenbodenbeschwerden bei weiblichen Fahrradfahrerinnen zusammen.brMethoden: Zwei Metadatenbanken, OvidSP und Deutsches Institut für Medizinische Dokumentation und Information (DIMDI, wurden auf Studien durchsucht, die über Genital- und Beckenbodenbeschwerden bei weiblichen Fahrradfahrerinnen berichteten und mögliche Therapie- oder Prophylaxeansätze untersuchten. Für die Literaturrecherche wurden folgende Schlagwörter verwendet: „female“, „bicycling“, „pelvic floor“, „lower urinary tract symptoms“ und „vulvar diseases“.brErgebnis: Die Suche ergab 1219 Artikel. Nach Entfernen der Duplikate aus dem Ergebnispool wurden 763 Publikationen nach relevanten Titeln untersucht. Letztendlich konnten 12 Fachartikel für unser Review herangezogen werden. 10 Studien waren Beobachtungsstudien und 2 experimentell. Symptome, die hierbei mit Fahrradfahren assoziiert wurden, waren: Schmerz und Neuropathien in der Beckenbodenregion sowie urologische Dysfunktionen und Hautverletzungen. Breitere und konventionelle Sättel führten zu einer geringeren Symptomatik als Sättel mit einer Lochung sowie schmälere Sportsättel.brZusammenfassung: Die Qualität der gegenwärtigen Studien war im Allgemeinen niedrig. Dennoch gibt es Evidenz dafür, dass Radfahrerinnen unter sehr ähnlichen Symptomen leiden wie Radfahrer: von kleineren Hautläsionen bis hin zu neurologischen Beschwerden.