WorldWideScience

Sample records for beams determinacao da

  1. Determination of average conversion coefficients between kerma in air and H⁎(10) using primary and secondary X-ray beams and transmitted in the diagnostic radiology energy range; Determinacao dos coeficientes de conversao medios entre kerma no ar e H*(10) usando feixes de raios-X primarios, secundarios e transmitidos na faixa de energia da radiologia diagnostica

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Josilene C.; Gonzalez, Alejandro H.L.; Costa, Paulo R. [Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil). Instituto de Fisica

    2016-07-01

    Brazilian regulation establishes 1.14 Sv/Gy as unique conversion coefficient to convert air-kerma into the operational quantity ambient dose equivalent H⁎(10) disregarding its beam quality dependence. The present study computed mean conversion coefficients from primary, secondary and transmitted X-ray beams through barite mortar plates used in shielding of dedicated chest radiographic facilities in order to improve the current assessment of H⁎(10). To compute the mean conversion coefficients, the weighting of conversion coefficients corresponding to monoenergetic beams with the spectrum energy distribution in terms of air-kerma was considered. The maximum difference between the obtained conversion coefficients and the constant value recommended in national regulation is 53.4%. The conclusion based on these results is that a constant coefficient is not adequate for deriving the H⁎(10) from air-kerma measurements. (author)

  2. Determination of atomic number and composition of human enamel; Determinacao da composicao e numero atomico efetivo do esmalte humano

    Energy Technology Data Exchange (ETDEWEB)

    Nogueira, M.S. [Centro Regional de Ciencias Nucleares (CRCN), Recife, PE (Brazil); Rodas Duran, J.E. [Sao Paulo Univ., Ribeirao Preto, SP (Brazil). Faculdade de Filosofia, Ciencias e Letras. Dept. de Fisica e Matematica

    2001-07-01

    The teeth are organs of complicated structure that consist, partly, of hard tissue containing in its interior the dental pulp, rich in vases and nerves. The main mass of the tooth is constituted by the dentine, which is covered with hard tissues and of epithelial origin called enamel. The dentine of the human teeth used in this work were completely removed and the teeth were cut with a device with a diamond disc. In this work the chemical composition of the human enamel was determined, which showed a high percentage of Ca and P, in agreement with the results found in the literature. The effective atomic number of the material and the half-value layer in the energy range of diagnostic X-ray beams were determined. Teeth could be used to evaluated the public's individual doses as well as for retrospective dosimetry what confirms the importance of their effective atomic number and composition determination. (author)

  3. Determination of the soil water retention curve by using gamma ray attenuation; Determinacao da curva de retencao da agua no solo com auxilio da transmissao de raios gama

    Energy Technology Data Exchange (ETDEWEB)

    Pires, Luiz F.; Bacchi, Osny O. S. [Centro de Energia Nuclear na Agricultura (CENA), Piracicaba, SP (Brazil)

    2002-07-01

    The soil water retention curve relates the soil water matric potential ({psi}{sub m}) and the soil moisture ({theta}). When no significant changes occur in soil structure, the water retention curve can be considered as a soil physical characteristic. This article presents a new procedure for soil water retention curve evaluation using gamma-ray beam attenuation as an auxiliary technique for soil moisture determination. The radioactive source used in the experiment was {sup 241} Am, and the detector was a 3 in. x 3 in. NaI(Tl) scintillation crystal coupled to a photomultiplier tube. The proposed procedure avoids the need of frequent sample manipulation as in the case of the conventional method. The soil moisture can be continuously monitored inside the chamber allowing a more precise judgment of the equilibrium. The time required for the retention curve determination can be significantly reduced in comparison with the traditional method. The results obtained show that the new procedure presents many advantages in relation to the traditional method and that it can be routinely used for soil water retention curve determination. (author)

  4. Determination of absorbed dose in electron beams using parallel-plane ionization chambers; Determinacao de dose absorvida em feixes de eletrons utilizando camaras de ionizacao de placas paralelas

    Energy Technology Data Exchange (ETDEWEB)

    Bulla, Roseli T.; Caldas, Linda V.E. [Instituto de Pesquisas Nucleares (IPEN), Sao Paulo, SP (Brazil)]. E-mail: lcaldas@ipen.br

    2004-06-01

    Objective: The objective of this paper was to establish a procedure for the determination of calibration factors and absorbed doses in electron beams. Materials And Methods: An irradiator with a {sup 60} Co source and a linear accelerator Varian, Clinac 2100C, with photon and electron beams, were utilized. Thimble type and parallel-plane ionization chambers were tested. Results: The measurement systems showed very good results in the preliminary tests (response stability and leakage current). The ionization chambers used for electron beam dosimetry were calibrated using four different methods. For the determination of absorbed dose, three methodologies recommended by the International Atomic Energy Agency were applied. Concordant results were obtained in almost all cases. Conclusion: The majority of the ionization chambers tested showed good results according to the established international limits. (author)

  5. Mineral water {sup 222} Rn activity decrease due to consumption habits; Determinacao do decrescimo da atividade de radonio-222 em aguas minerais simulando habitos de consumo

    Energy Technology Data Exchange (ETDEWEB)

    Cipriani, Moacir; Taddei, Maria Helena Tirollo; Silva, Nivaldo Carlos da [Comissao Nacional de Energia Nuclear (CNEN), Pocos de Caldas, MG (Brazil). Laboratorio

    2001-07-01

    Mineral waters from the Pocos de Caldas Plateau springs, an elevated region with high natural radioactivity, in the State of Minas Gerais, Brazil, have significant {sup 222} Rn concentration on site. The highest concentration in the waters are from: Fonte Villela - Aguas da Prata ({approx} 1000 Bql{sup -1}); Fonte Grande Hotel - Pocinhos do Rio Verde ({approx} 400 Brq{sup -1}) and Fonte CNEN Lab - Pocos de Caldas ({approx} 290 Bql{sup -1}). These waters are used by the population as drinking water and due to consumption habits, can lead to internal doses above accepted limits for the public. This work deals with the decrease of {sup 222} Rn activity in mineral waters fro two different popular consumption habits, and with the adult effective dose equivalent reduction due to water consumption habits. It has been found that the estimated dose based on the biokinetic Crawford-Brown model, can be one fourth of dose based on {sup 222} Rn activity on site. (author)

  6. Determination of the initial energy in computerized tomography with proton beams; Determinacao da energia inicial em tomografia computadorizada com feixe de protons

    Energy Technology Data Exchange (ETDEWEB)

    Rocha, Rodrigo Luis da

    2007-07-01

    In earliest works devoted to proton computed tomography it was shown that the advantage of pCT image reconstruction appears when the energy is close to the Bragg peak region, since the proton passes the object. This effect provided by the Bragg peak makes the computerized tomography with protons possible. However, when decreasing the initial proton energy, with the increase of the irradiation dose, there are two effects that work simultaneously in opposite ways. First, the energy loss of a proton in an object becomes bigger at small initial energy. At the same time decreasing of the proton energy results in the increase of the energy straggling, requiring a larger number of protons. In this work the radiation dose dependence on the proton initial energy was studied using analytical formulas and computer simulations. The investigation determined that the radiation dose practically does not depend on the initial energy, except in the energy region very close to the minimum energy necessary to pass the object. (author)

  7. Considerations on scattering and leak radiation for effective determination of secondary shielding in X-rays rooms of megavoltage; Consideracoes sobre radiacoes de espalhamento e vazamento para determinacao eficaz da barreira secundaria em salas de raios-x de megavoltagem

    Energy Technology Data Exchange (ETDEWEB)

    Borges, Diogo da S.; Lava, Deise D.; Affonso, Renato R.W.; Moreira, Maria de L.; Guimaraes, Antonio C.F., E-mail: diogosb@outlook.com, E-mail: deise_dy@hotmail.com, E-mail: raoniwa@yahoo.com.br, E-mail: malu@ien.gov.br, E-mail: tony@ien.gov.br [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2014-07-01

    This paper addresses the development of a algorithm capable of analyzing the thickness of the secondary shielding due to the production of secondary beams. The production of this beam requires consideration of scattering angle, as well as factors normally used for screening of medical facilities using radiographic techniques. Besides the beam emanated from scattering radiation, is is necessary to evaluate the contribution of leakage radiation, originating from equipment used for the production of the primary beam. A view of the mutual contribution of these radiation to the formation of the secondary beam has shown the need of using shieldings in adjacent walls of the room. The code was validated by comparison with an example case provided by NCRP-151 Report. In this report calculations for determining the secondary barrier for small angles are presented, that deserves greater attention for shielding and statements related to radiotherapy procedures of Modulated intensity. The results are consistent with those provided in the report, which makes the code can be used as a practical tool for the determination of effective shielding beams of megavoltage X-rays.

  8. Determination of absorbed dose in water: evaluation of dosimetric factors calibration sets used in radiotherapy; Determinacao da dose absorvida na agua: avaliacao dos fatores de calibracao de conjuntos dosimetricos de uso em radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, Marco A.R. [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Botucatu, SP (Brazil). Faculdade de Medicina. Departamento de Dermatologia e Radioterapia; Fontana, Julia M.; Santos, Vitor H.P.; Nunes, Isabella P.F.; Okawabata, Francine S., E-mail: marfernandes@fmb.unesp.br [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Botucatu, SP (Brazil). Instituto de Biociencia

    2014-12-15

    This paper presents a methodology for measuring the dose rate (cGy/min) in a telecobaltotherapy beam, looking emphasize the need for calibration of dosimetric set used and the importance of conducting periodic clinical megavoltage dosimetry of these beams. Two dosimetric set with their respective calibration factors were used. The correction parameters indicated in dosimetry protocols were determined by ionization chambers used. The difference between the value of the dose rate used in the calculation of the service routine and the values obtained in this work with both dosimetric sets proved to be less than 1.5%, and therefore satisfies the maximum recommended tolerance on quality control protocols for this type of therapeutic beam. (author)

  9. Use of thin layer chromatography for the determination of radiochemical purity of radiopharmaceuticals in nuclear medicine services of Paraiba and Rio Grande do Norte, Brazil; Utilizacao da cromatografia em camada delgada para determinacao da pureza radioquimica de radiofarmacos em servicos de medicina nuclear da Paraiba e Rio Grande do Norte, Brasil

    Energy Technology Data Exchange (ETDEWEB)

    Andrade, W.G.; Santos, P.A.L.; Lima, F.R.A. [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Programa de Pos-Graduacao em Tecnologia Energetica; Lima, F.F., E-mail: wellington.gandrade@gmail.com [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil)

    2012-07-01

    The paper chromatography and the thin layer chromatography are separation techniques in which the radioactive components migrate because of their affinity with the eluent (mobile phase) or stationary phase, respectively. In radiopharmaceuticals labeled with {sup 99m}Tc, besides its own radiopharmaceutical, {sup 99m}TcO{sup 4-} free and TcO{sub 2} can be identified and quantified. The evaluation of radiochemical purity of radiopharmaceuticals is essential to produce images free of artifacts as well as avoid unnecessary absorbed dose to the patient. Once they are managed in humans it is important and necessary that they undergo to strict quality control. Because of this, ANVISA in its 'Resolucao da Diretoria Colegiada (RDC) 38 of June 4th, 2008 states the obligation of performing a minimum of tests in nuclear medicine services routine prior to human administration. This work evaluated, by the method of thin layer chromatography (TLC), radiochemical purity, determined the pH of the radiopharmaceutical DEXTRAN- 500, DMSA, DTPA, PHYTATE, MDP, MIBI and Sn-Col used in nuclear medicine services in the states of Paraiba and Rio Grande do Norte - Brazil. The results show that the use of thin layer chromatography (TLC) as a standard method in routine of nuclear medicine services is possible, because it provides important data for the evaluation of radiochemical purity, allowing the exclusion of a radiopharmaceutical poorly marked. (author)

  10. Fast IR Array Detector for Transverse Beam Diagnostics at DA{\\Phi}NE

    CERN Document Server

    Bocci, A; Clozza, A; Drago, A; Grilli, A; Marcelli, A; Raco, A; Sorchetti, R; Gambicorti, L; De Sio, A; Pace, E; Piotrowski, J

    2010-01-01

    At the Laboratori Nazionali di Frascati of the National Institute of Nuclear Physics (INFN) an infrared (IR) array detector with fast response time has been built and assembled in order to collect the IR image of e-/e+ sources of the DA{\\Phi}NE collider. Such detector is made by 32 bilinear pixels with an individual size of 50x50 {\\mu}m2 and a response time of ~1 ns. In the framework of an experiment funded by the INFN Vth Committee dedicated to beam diagnostics, the device with its electronic board has been tested and installed on the DA{\\Phi}NE positron ring. A preliminary characterization of few pixels of the array and of the electronics has been carried out at the IR beamline SINBAD at DA{\\Phi}NE. In particular the detection of the IR source of the e- beam has been observed using four pixels of the array acquiring signals simultaneously with a four channels scope at 1 GHz and at 10 Gsamples/s. The acquisition of four pixels allowed monitoring in real time differences in the bunch signals in the vertical d...

  11. Characterization of a tagged $\\gamma$-ray beam line at the DA$\\Phi$NE Beam Test Facility

    CERN Document Server

    Cattaneo, P W; Boffelli, F; Bulgarelli, A; Buonomo, B; Chen, A W; D'Ammando, F; Froysland, T; Fuschino, F; Galli, M; Gianotti, F; Giuliani, A; Longo, F; Marisaldi, M; Mazzitelli, G; Pellizzoni, A; Prest, M; Pucella, G; Quintieri, L; Rappoldi, A; Tavani, M; Trifoglio, M; Trois, A; Valente, P; Vallazza, E; Vercellone, S; Zambra, A; Barbiellini, G; Caraveo, P; Cocco, V; Costa, E; De Paris, G; Del Monte, E; Di Cocco, G; Donnarumma, I; Evangelista, Y; Feroci, M; Ferrari, A; Fiorini, M; Labanti, C; Lapshov, I; Lazzarotto, F; Lipari, P; Mastropietro, M; Mereghetti, S; Morelli, E; Moretti, E; Morselli, A; Pacciani, L; Perotti, F; Piano, G; Picozza, P; Pilia, M; Porrovecchio, G; Rapisarda, M; Rubini, A; Sabatini, S; Soffitta, P; Striani, E; Vittorini, V; Zanello, D; Colafrancesco, S; Giommi, P; Pittori, C; Santolamazza, P; Verrecchia, F; Salotti, L

    2011-01-01

    At the core of the AGILE scientific instrument, designed to operate on a satellite, there is the Gamma Ray Imaging Detector (GRID) consisting of a Silicon Tracker (ST), a Cesium Iodide Mini-Calorimeter and an Anti-Coincidence system of plastic scintillator bars. The ST needs an on-ground calibration with a $\\gamma$-ray beam to validate the simulation used to calculate the energy response function and the effective area versus the energy and the direction of the $\\gamma$ rays. A tagged $\\gamma$-ray beam line was designed at the Beam Test Facility (BTF) of the INFN Laboratori Nazionali of Frascati (LNF), based on an electron beam generating $\\gamma$ rays through Bremsstrahlung in a position-sensitive target. The $\\gamma$-ray energy is deduced by difference with the post-Bremsstrahlung electron energy \\cite{prest}-\\cite{hasan}. The electron energy is measured by a spectrometer consisting of a dipole magnet and an array of position sensitive silicon strip detectors, the Photon Tagging System (PTS). The use of the...

  12. Measurement of conversion coefficients between air Kerma and personal dose equivalent and backscatter factors for diagnostic X-ray beams; Determinacao experimental dos coeficientes de conversao de Kerma no ar para o equivalente de dose pessoal, Hp(d), e fatores de retroespalhamento em feixes de raios-x diagnostico

    Energy Technology Data Exchange (ETDEWEB)

    Rosado, Paulo Henrique Goncalves

    2008-07-01

    Two sets of quantities are import in radiological protection: the protection and operational quantities. Both sets can be related to basic physical quantities such as kerma through conversion coefficients. For diagnostic x-ray beams the conversion coefficients and backscatter factors have not been determined yet, those parameters are need for calibrating dosimeters that will be used to determine the personal dose equivalent or the entrance skin dose. Conversion coefficients between air kerma and personal dose equivalent and backscatter factors were experimentally determined for the diagnostic x-ray qualities RQR and RQA recommended by the International Electrotechnical Commission (IEC). The air kerma in the phantom and the mean energy of the spectrum were measured for such purpose. Harshaw LiF-100H thermoluminescent dosemeters (TLD) were used for measurements after being calibrated against an 180 cm{sup 3} Radcal Corporation ionization chamber traceable to a reference laboratory. A 300 mm x 300 mm x 150 mm polymethylmethacrylate (PMMA) slab phantom was used for deep-dose measurements. Tl dosemeters were placed in the central axis of the x-ray beam at 5, 10, 15, 25 and 35 mm depth in the phantom upstream the beam direction Another required parameter for determining the conversion coefficients from was the mean energy of the x-ray spectrum. The spectroscopy of x-ray beams was done with a CdTe semiconductor detector that was calibrated with {sup 133} Ba, {sup 241} Am and {sup 57} Co radiation sources. Measurements of the x-ray spectra were carried out for all RQR and RQA IEC qualities. Corrections due to the detector intrinsic efficiency, total energy absorption, escape fraction of the characteristic x-rays, Compton effect and attenuation in the detector were done aiming an the accurate determination of the mean energy. Measured x-ray spectra were corrected with the stripping method by using these response functions. The typical combined standard uncertainties of

  13. X-ray cone beam microtomography for quantitative assessment of tracheal and pharyngeal volumes of Rhodnius prolixus; Utilizacao da microtomografia computadorizada com feixe de raios-X conico para a determinacao quantitativa do volume da traqueia e faringe do Rhodnius prolixus

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Izabella Soares de

    2017-07-01

    In the past decade microcomputerized tomography imaging using synchrotron radiation has become a powerful technique to generate high resolution images of Rhodinus prolixus. Images of soft tissues (protocerebrum and muscles) and dense structures (pharynx, trachea and esophagus) of R. prolixus head have been obtained using synchrotron radiation microtomography in mono and polychromatic configuration, respectively. Advancements in conventional microtomography have increased the achievable resolution and contrast, making this relatively inexpensive and widely available technology potentially useful for studies of insect internal morphology. The main goal of this work was to provide a new set of high quality microtomographic images of R. prolixus achieved by means of a desktop X-ray microtomograph. It allows the three-dimensional visualization of important chitinized structures: pharynx and tracheae. Pharyngeal and tracheal volumes were quantitatively evaluated at different days (1, 4, 10, 15 and 20) after feeding. The results suggest that variation of average volumes could be attributed to insect hormone 20-hydroxy-ecdysone (20-OH-Ec) pulse at 11 days after feeding. Pharyngeal volumes decrease 3.80 times. On the other hand, tracheal volumes increase 1.78 times. Head total volume showed similar trends than trachea. (author)

  14. Determination of butadiene commercial elastomers composition; Determinacao da composicao de elastomeros comerciais a base de butadieno

    Energy Technology Data Exchange (ETDEWEB)

    Tavares, M.I.B.; Mendes, L.C. [Universidade Federal, Rio de Janeiro, RJ (Brazil). Inst. de Macromoleculas

    1997-12-31

    Hydrogen-1 nuclear magnetic resonance was used in the determination of the percentile and conformational composition of commercial samples of styrene-butadiene-copolymer and poly(butadiene) homo-polymer. The results are presented and discussed 3 refs., 5 figs., 1 tab.

  15. Determination of the fraction of amorphous phases in superconducting samples; Determinacao da fracao de fases amorfas em amostras supercondutoras

    Energy Technology Data Exchange (ETDEWEB)

    Gomes Junior, G.G.; Ogasawara, T., E-mail: georgeg@metalmat.ufjr.b [Universidade Federal do Rio de Janeiro (COPPE/UFRJ), RJ (Brazil). Coordenacao dos Programas de Pos-Graduacao de Engenharia. Dept. de Eng. Metalurgica e Materiais; Bispo, E.R.; Polasek, A. [Centro de Pesquisas de Energia Eletrica (CEPEL), Rio de Janeiro, RJ (Brazil); Amorim, H.S. [Universidade Federal do Rio de Janeiro (IF/UFRJ), RJ (Brazil). Inst. de Fisica

    2010-07-01

    The study phase formation of high critical temperature superconducting (Bi, Pb) - 2223 by partial melting and recrystallization aims to improve the microstructure of the material. Was used for X-ray diffraction characterization of the phases present. The DDM method (Derivative Difference Minimization) was used for the refinement of structures, quantification of the phases and determination the fraction of this amorphous. The advantage this method is not necessary to introduce an internal standard to determine the amorphous fraction. Were observed in the powder precursor phases (Bi, Pb) {sub 2}Sr{sub 2}Ca{sub 2}Cu{sub 3}O{sub x} (Bi, Pb) -2223, 93% of the sample, Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub y} (Bi-2212) and Bi{sub 2}Sr{sub 2}CuO{sub z} (Bi-2201). The powder precursor was heat treated at 820-870 deg C. To minimize volatilization of lead, the material was placed in silver crucibles closed. To get a high recovery of (Bi, Pb) - 2223, the material was cooled slowly, due to slow kinetic of formation of this phase. We observed a partial recovery phase (Bi, Pb) -2223. (author)

  16. Determination of viability of irradiated `pera` orange protoplasts; Determinacao da viabilidade de protoplastos irradiados de laranja pera

    Energy Technology Data Exchange (ETDEWEB)

    Cristofani, M. [Instituto Agronomico de Campinas, SP (Brazil); Mendes, B.J.; Tulmann Neto, A.; Ando, A. [Centro de Energia Nuclear na Agricultura (CENA), Piracicaba, SP (Brazil)

    1993-12-31

    The viability of sweet orange protoplants, submitted to different dosages of gamma radiation, was studied to determine the lethal dose. The analysis suggested that the viability was inversely proportional to gamma radiation and the lethal dose was established. 14 refs., 1 fig., 2 tabs.

  17. Viscosity of the gelatin powder irradiated with beam of electrons; Viscosidade da gelatina em po irradiada com feixe de eletrons

    Energy Technology Data Exchange (ETDEWEB)

    Vieira, Fernando F.; Mastro, Nelida L. del [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil)

    2000-07-01

    The objective of this work was to study the action of the radiation on the viscosity of the gelatin powder eatable. The material in powder was irradiated with electron beam proceeding from an accelerator of Dynamitron with a dose rate of 11,19 kGy/s with doses of 5, 10, 20 and 50 kGy. A Brookfield viscometer model DV-III and spindle SC4-18 was used coupled to a thermal-static bath Neslab model RTE-210, to carry through the measures of viscosity. The results show a gradual decrease in viscosity in function of the doses of radiation. The values of viscosity had been in 94% and 47%, for the doses of 5 kGy and 50 kGy respectively, in relation to the samples not irradiated, which evidences the high resistance of the gelatin front to the ionizing radiation, being considered the des-polymerization as the predominant phenomenon. (author)

  18. Evaluation of the repeatability of dosimetric parameters of a linear accelerator beam; Avaliacao da repetibilidade de parametros dosimetricos do feixe de um acelerador linear

    Energy Technology Data Exchange (ETDEWEB)

    Morelli, Humberto A.S.; Oliveira, Harley F. de; Silva, Maelson do N.; Pavoni, Juliana F., E-mail: h.morelli@hotmail.com [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Servico de Radioterapia

    2016-07-01

    This study aims to evaluate the repeatability of symmetry and flatness of the photon beam of 6 MV linear accelerator Oncor Impression, Siemens, from the Radiotherapy Department of the Hospital das Clinicas da Faculdade de Medicina de Ribeirao Preto - USP. In total they were collected 102 measures, weekly, through two-dimensional detector of ionization chambers, Matrixx Evolution, IBA Dosimetry, connected to a computer with software OmniProI'mrt. The isocenter of the linear accelerator was placed in the center of the sensitive volume of the detector with solid water plates above and below these. Data were collected with 100 UM, with field size 10 x 10 cm². The flatness and symmetry values were calculated by the software used. The first measurement of this work was used as reference, the others were compared with it, taking into account the values of permissible variation for these parameters. The minimum, maximum and average value were analyzed. The literature indicates that the flatness and symmetry values should not vary by more than 2 and 3%, respectively. The results of this work show that the values of these parameters for the linear accelerator study are within the permissible variations in protocols and are therefore able to appropriate clinical use. (author)

  19. Verificação do fator de calibração e indicador da qualidade do feixe de aceleradores lineares Verification of dose output and beam quality indicator in linear accelerators

    Directory of Open Access Journals (Sweden)

    Maria da Penha Silva

    2001-10-01

    Full Text Available Um programa de garantia da qualidade é um pré-requisito obrigatório para a exatidão necessária em radioterapia. Este trabalho relata parte dos testes de rotina mensal do controle da qualidade dos aceleradores lineares do Instituto Nacional do Câncer, relativos à calibração dos feixes de fótons e elétrons, no período de dois anos. Os resultados foram comparados com as recomendações do protocolo AAPM TG-40. Na análise do fator de calibração para o feixe de fótons foi encontrado um desvio máximo de 12%; para o feixe de elétrons o maior desvio encontrado foi 10%. A flutuação observada no indicador da qualidade do feixe para os feixes de elétrons foi maior que para os feixes de fótons. Os resultados confirmam a importância de um programa de garantia da qualidade em um serviço de radioterapia, permitindo correções rápidas da dose administrada ao paciente.A quality assurance program is a mandatory prerequisite for obtaining the high level of accuracy required for radiotherapy. This paper reports the results of part of the routine quality control tests for linear accelerators at the National Cancer Institute, Brazil, performed monthly over a period of two years. These tests included dose output and beam quality indicator. The results were compared with the guidelines of the AAPM TG-40 protocol. The results for the photon beams have shown dose output variations of up to 12%; for electron beams, the largest deviation found was 10%. The fluctuations observed in the beam quality indicator for the electron beams were greater than for the photon beams. These results strongly emphasize the importance of a quality assurance program in radiotherapy services in order to allow prompt corrections of the dose delivered to the patient.

  20. Efeitos transversais da expansão rápida da maxila em pacientes com má oclusão de Classe II: avaliação por Tomografia Computadorizada Cone-Beam Transverse effects of rapid maxillary expansion in Class II malocclusion patients: a Cone-Beam Computed Tomography study

    Directory of Open Access Journals (Sweden)

    Carolina Baratieri

    2010-10-01

    Full Text Available OBJETIVO: avaliar por meio de Tomografia Computadorizada Cone-Beam (TCCB os efeitos transversais, imediatos e após o período de contenção, da expansão rápida da maxila (ERM em pacientes com má oclusão de Classe II. MÉTODOS: dezessete crianças (idade inicial média de 10,36 anos com má oclusão de Classe II e deficiência transversal esquelética da maxila foram submetidas ao protocolo de ERM com aparelho expansor de Haas. TCCBs foram realizadas antes dos procedimentos clínicos (T1, imediatamente após a estabilização do parafuso expansor (T2 e após completados 6 meses de contenção e removido o aparelho (T3. Com o software Dolphin, foram possíveis a manipulação das imagens e as mensurações. O teste t de Student pareado foi utilizado para identificar significância estatística (pOBJECTIVE: The aim of this study was to evaluate by Cone-Beam Computed Tomography (CBCT transversal responses, immediately and after the retention period, to rapid maxillary expansion (RME, in Class II malocclusion patients. METHODS: Seventeen children (mean initial age of 10.36 years, with Class II malocclusion and skeletal constricted maxilla, underwent Haas´ protocol for RME. CBCT scans were taken before treatment (T1, at the end of the active expansion phase (T2 and after the retention period of six months (T3. The scans were managed in Dolphin software, where landmarks were marked and measured, on a coronal slice passing through the upper first molar. The paired Student´s t-test was used to identify significant differences (p<0.05 between T2 and T1, T3 and T2, and T3 and T1. RESULTS: Immediately after RME, the mean increase in maxillary basal, alveolar and dental width was 1.95 mm, 4.30 mm and 6.89 mm, respectively. This was accompanied by buccal inclination of the right (7.31° and left (6.46° first molars. At the end of the retention period, the entire transverse dimension increased was maintained and the dentoalveolar inclination resumed

  1. Determination of the crust thickness in the active margin of the Antarctic region; Determinacao da estrutura crustal na margem ativa da regiao antartica

    Energy Technology Data Exchange (ETDEWEB)

    Torres, Luiz Carlos; Gamboa, Luiz Antonio Pierantoni [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Lagemar; Gomes, Benedito Souza [PETROBRAS, Rio de Janeiro, RJ (Brazil)

    1997-07-01

    Seismic multichannel, gravity and magnetometry measurements were carried out in the region of West coast of the Antarctic Peninsula, Bransfield Strait, South Shetland Islands and South Shetland Trench, by Brazilian Antarctic Program during the summers of 1987 and 1988. The present work, using a continue seismic and gravity and gravity data profile crossing the area, intends to present a two-dimensional model of the crust thickness in this region. By this model, the Moho discontinuity would lie at a depth of 14.5 km below the axis of the Bransfield trough. This anomalous behaviour in addition to compressional processes identified in the accretionary prism and trench, was interpreted as an evidence of the continued opening of the Bransfield basin. (author)

  2. Reprodutibilidade das mensurações da espessura das tábuas ósseas na tomografia computadorizada Cone-Beam utilizando diferentes protocolos de aquisição de imagem Reproducibility of bone plate thickness measurements with Cone-Beam Computed Tomography using different image acquisition protocols

    Directory of Open Access Journals (Sweden)

    Carolina Carmo de Menezes

    2010-10-01

    Full Text Available INTRODUÇÃO: quanto menor a dimensão do voxel, maior a nitidez da imagem de tomografia computadorizada Cone-Beam (TCCB, porém, maior a dose de radiação emitida. OBJETIVOS: avaliar e comparar a reprodutibilidade da mensuração da espessura das tábuas ósseas vestibular e lingual em imagens de TCCB, utilizando diferentes protocolos de aquisição de imagem com variação da dimensão do voxel. MÉTODOS: exames de TCCB foram tomados de 12 mandíbulas humanas secas, com dimensão do voxel de 0,2; 0,3 e 0,4mm, no aparelho i-CAT Cone-Beam 3-D Dental Imaging System. No software i-CAT Viewer, foi mensurada a espessura das tábuas ósseas vestibular e lingual, em um corte axial passando 12mm acima do forame mentoniano do lado direito. A reprodutibilidade intraexaminador foi avaliada por meio da aplicação do teste t pareado. Para a comparação interexaminadores, foi utilizado o teste t independente. Os resultados foram considerados com o nível de significância de 5%. RESULTADOS: observou-se uma excelente reprodutibilidade interexaminadores para os três protocolos avaliados. A reprodutibilidade intraexaminadores foi muito boa, com exceção de algumas regiões dos dentes anteriores, que mostraram diferenças estatisticamente significativas, independentemente da dimensão do voxel. CONCLUSÃO: a mensuração da espessura das tábuas ósseas vestibular e lingual em imagens de TCCB mostrou boa precisão para exames obtidos com voxel de 0,2; 0,3 ou 0,4mm. A reprodutibilidade das mensurações na região anterior da mandíbula foi mais crítica do que na região posterior.INTRODUCTION: A smaller voxel dimension leads to greater resolution of Cone-Beam Computed Tomography (CBCT, but a greater dosage of radiation is emitted. OBJECTIVE: Assess and compare the reproducibility of buccal and lingual bone plate thickness measurements in CBCT images using different image acquisition protocols, with variations in the voxel dimension. METHODS: CBCT exams

  3. Cone beam computed tomography in veterinary dentistry: description and standardization of the technique; Tomografia computadorizada de feixe conico na odontologia veterinaria: descricao e padronizacao da tecnica

    Energy Technology Data Exchange (ETDEWEB)

    Roza, Marcello R. [Universidade Federal de Goias (UFG), Goianai, GO (Brazil)], e-mail: marcelloroza@gmail.com; Silva, Luiz A.F.; Fioravanti, Maria C. S. [Universidade Federal de Goias (UFG), Goiania, GO (Brazil). Escola de Veterinaria. Dept. de Medicina Veterinaria; Januario, Alessandro L. [International Team for Implantology (ITI), Sao Paulo, SP (Brazil); Barriviera, Mauricio [Universidade Catolica de Brasilia (UCB), DF (Brazil). Faculdade de Odontologia. Dept. de Radiologia; Oliveira, Alexandre C.A. [Faculdade de Odontologia Sao Leopoldo Mandic, Campinas, SP (Brazil)

    2009-08-15

    Eleven dogs and four cats with buccodental alterations, treated in the Centro Veterinario do Gama, in Brasilia, DF, Brazil, were submitted to cone beam computed tomography. The exams were carried out in a i-CAT tomograph, using for image acquisition six centimeters height, 40 seconds time, 0.2 voxel, 120 kilovolts and 46.72 milli amperes per second. The ideal positioning of the animal for the exam was also determined in this study and it proved to be fundamental for successful examination, which required a simple and safe anesthetic protocol due to the relatively short period of time necessary to obtain the images. Several alterations and diseases were identified with accurate imaging, demonstrating that cone beam computed tomography is a safe, accessible and feasible imaging method which could be included in the small animal dentistry routine diagnosis. (author)

  4. Evaluation of toxicity and removal of color in textile effluent treated with electron beam; Avaliacao da toxicidade e remocao da cor de um efluente textil tratado com feixe de eletrons

    Energy Technology Data Exchange (ETDEWEB)

    Morais, Aline Viana de

    2015-07-01

    The textile industry is among the main activities Brazil, being relevant in number of jobs, quantity and diversity of products and mainly by the volume of water used in industrial processes and effluent generation. These effluents are complex mixtures which are characterized by the presence of dyes, surfactants, metal sequestering agents, salts and other potentially toxic chemicals for the aquatic biota. Considering the lack of adequate waste management to these treatments, new technologies are essential in highlighting the advanced oxidation processes such as ionizing radiation electron beam. This study includes the preparation of a standard textile effluent chemical laboratory and its treatment by electron beam from electron accelerator in order to reduce the toxicity and intense staining resulting from Cl. Blue 222 dye. The treatment caused a reduction in toxicity to exposed organisms with 34.55% efficiency for the Daphnia similis micro crustacean and 47.83% for Brachionus plicatilis rotifer at a dose of 2.5 kGy. The Vibrio fischeri bacteria obtained better results after treatment with a dose of 5 kGy showing 57.29% efficiency. Color reduction was greater than 90% at a dose of 2.5 kGy. This experiment has also carried out some preliminary tests on the sensitivity of the D. similis and V. fischeri organisms to exposure of some of the products used in this bleaching and dyeing and two water reuse simulations in new textile processing after the treating the effluent with electron beam. (author)

  5. Determination of bone mineral density of the distal extremity of the radio in Rottweiller, by radiographic optic densitometry;Determinacao da densidade mineral ossea da extremidade distal do radio de caes da raca Rottweiller, por meio da densitometria optica radiografica

    Energy Technology Data Exchange (ETDEWEB)

    Alves, Jefferson Douglas Soares, E-mail: radiologia@unifeob.edu.b [Fundacao de Ensino Octavio Bastos (UNIFEOB), Sao Joao da Boa Vista, SP (Brazil). Fac. de Medicina e Veterinaria; Sterman, Franklin de Almeida [Universidade de Sao Paulo (USP), Butanta, SP (Brazil). Fac. de Medicina Veterinaria e Zootecnia. Dept. de Cirurgia

    2010-06-15

    This study allowed the standardization of the bone mineral density (BMD) of the distal extremity of the radio of 36 dogs adults in Rottweiler breed by radiographic optic densitometry. The limbs of the animals were radiographed with scale of aluminum that served as a reference. The radiographs images were digitalized and analyzed by a computer program for comparison of gray tones between the standard image and the image of the reference scale radiographed with the bone. Afterwards the values of density were expressed in millimeters of aluminum. Also studied the correlations between BMD and the sex, weight and external measures as the length of spine, height of the animal and circumference the distal extremity of the limb in study. The mean values and standard deviations of the bone mineral density of the distal extremity of the radio were: for the metaphyseal region the average of BMD of 7,88+-0,89 mmAl, the diaphyseal region 1 the average of BMD of 8,58+-0,80 mmAl and for diaphyseal region 2 of BMD of 9,00+-0,74 mmAl. (author)

  6. Avaliação do espaço aéreo faríngeo por meio da tomografia computadorizada de feixe cônico Assessment of pharyngeal airway space using Cone-Beam Computed Tomography

    Directory of Open Access Journals (Sweden)

    Sabrina dos Reis Zinsly

    2010-10-01

    Full Text Available INTRODUÇÃO: a avaliação do espaço aéreo superior faz parte da rotina na elaboração do diagnóstico e plano de tratamento ortodôntico. A radiografia cefalométrica em norma lateral tem sido usada rotineiramente na avaliação da permeabilidade do espaço aéreo, esbarrando na limitação de fornecer uma imagem bidimensional de uma estrutura tridimensional. A Tomografia Computadorizada de Feixe Cônico (TCFC tem entrado na realidade ortodôntica trazendo um arsenal de informações concernentes ao espaço aéreo superior. Por fornecer uma imagem tridimensional, possibilita determinar de maneira precisa a área de maior estreitamento da faringe, que ofereceria maior resistência à passagem aérea. OBJETIVOS: o propósito deste artigo é esclarecer o ortodontista quanto aos recursos disponíveis na TCFC para o diagnóstico de possíveis barreiras físicas que possam diminuir a permeabilidade das vias aéreas superiores.INTRODUCTION: Evaluation of upper airway space is a routine procedure in orthodontic diagnosis and treatment planning. Although limited insofar as they provide two dimensional images of three-dimensional structures, lateral cephalometric radiographs have been used routinely to assess airway space permeability. Cone-Beam Computed Tomography (CBCT has contributed to orthodontics with information concerning the upper airway space. By producing three-dimensional images CBCT allows professionals to accurately determine the most constricted area, where greater resistance to air passage occurs. OBJECTIVES: The purpose of this article is to enlighten orthodontists on the resources provided by CBCT in the diagnosis of possible physical barriers that can reduce upper airway permeability.

  7. Evaluation of fracture toughness in dental ceramics using indentation and SEVNB (Single Edge V-Notched Beam)-method; Avaliacao da tenacidade a fratura de ceramicas dentarias atraves do metodo de entalhe - SEVNB (Single Edge V-Notched Beam)

    Energy Technology Data Exchange (ETDEWEB)

    Santos, L.A.; Santos, C.; Souza, R.C.; Ribeiro, S. [Universidade de Sao Paulo (DEMAR/EEL/USP), Lorena, SP (Brazil). Escola de Engenharia de Lorena. Dept. de Engenharia de Materiais. Polo Urbo-Industrial; Strecker, K. [Universidade Federal de Sao Joao del-Rei (DME/UFSJ), MG (Brazil). Dept. de Materiais Eletricos; Oberacker, R. [Karlsruhe Univ. (Germany)

    2009-07-01

    In this work, the fracture toughness of different ceramics based on Al{sub 2}O{sub 3} and ZrO{sub 2} were evaluated using, comparatively two methods, Vickers indentation and SEVNB (Single Edge V-Notched Beam) method. Al{sub 2}O{sub 3}, ZrO{sub 2}(3%Y{sub 2}O{sub 3}) micro-particled and ZrO{sub 2}(3%Y{sub 2}O{sub 3}) nanometric, ZrO{sub 2}-Al{sub 2}O{sub 3} and Al{sub 2}O{sub 3}-ZrO{sub 2} composites were sintered at different temperatures. Samples were characterized by relative density, X-ray diffraction, SEM, and mechanical evaluation by hardness, bending strength and fracture toughness obtained by ickers indentation and SEVNB-method. The results were presented comparing the densification and microstructural results. Furthermore, the advantages and limitations of each method were discussed. (author)

  8. Determination of the hexagonal network parameters of the quartz {beta} using neutron multiple diffraction; Determinacao dos parametros da rede hexagonal do quartzo {beta} utilizando difracao multipla de neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Campos, L.C.; Parente, C.B.R.; Mazzocchi, V.L. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)], e-mail: lccampos@curiango.ipen.br; Helene, O. [Universidade de Sao Paulo (USP), SP (Brazil)], e-mail: otaviano@if.usp.br

    2000-07-01

    In this work, neutron multiple diffraction is employed for the determination of the parameters a and c of the {beta}-quartz hexagonal cell. This crystalline phase of silica (SiO{sub 2}) occurs in temperatures between ca. 846 and 1143 K. A {beta}-quartz neutron multiple diffraction pattern has been used in the determinations. This pattern was obtained with a natural quartz single crystal heated to 1003 K. During the indexing of the pattern it was verified that most of the pairs of secondary reflections, which are responsible for the formation of peaks, could be classified as 'good for the determination of a' or 'good for the determination of c'. With this classification, it became possible to employ an iterative method for the determination of both parameters. After 8 cycles of iteration the values found for the parameters were a = 4.9964 +- 0.0018 and c = 5.46268 +- 0.00052 A. (author)

  9. Permeability evaluation of reservoir rocks modeled in multi scale percolation systems; Determinacao da permeabilidade de rochas reservatorio reconstruidas em sistemas de percolacao multiescala

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, Celso P.; Philippi, Paulo C.; Damiani, Marcos C.; Cunha Neto, Jose A.B. da [Santa Catarina Univ., Florianopolis, SC (Brazil). Dept. de Engenharia Mecanica. Lab. de Meios Porosos e Propriedades Termofisicas]. E-mail: celso@lmpt.ufsc.br; philippi@lmpt.ufsc.br; damiani@lmpt.ufsc.br; bellini@lmpt.ufsc.br; Daian, Jean-Francois (Laboratoire d' Etudes des Transferts en Hydrologie et Environement)

    2000-07-01

    Multiscale percolation systems (MPS) are presented as giving a fast method for calculating intrinsic permeability of porous media. MPS were proposed to study invasion processes in porous media considering the porous section as a polydisperse structure, which modify its geometrical structure when the scale of observation is changed. Multiscale models are non-regular percolation systems and do not have the following limitations common to classical percolation systems: it is not necessary to choose a particular value for the coordination number; constrictions appears naturally as pores of smaller diameters connecting pores of greater diameters, as the result of superposing different scales (Fernandes, C. P., Magnani, F.S., Philippi, P.C., Daian, J.F. 1996, Multiscale reconstruction of the porous structure, Physical Review E, 54, 1734-1742). Present paper describes the numerical prediction of intrinsic permeability of petroleum reservoir rocks by using a MPS approach. Rock's microstructure is reconstructed in a three dimensional MPS, starting from 2D thin sections geometrical information, after binarization and microstructural analysis. Intrinsic permeability is, then, calculated, using a procedure based on renormalization theory. The method is presented and applied for the calculation of intrinsic permeability of several petroleum reservoir rocks. Results are compared with experimental data. (author)

  10. Use of NOESYTP in stereochemistry determination of anew limonoid from Khaya senegalensis; Aplicacao de NOESYTP na determinacao da estereoquimica de um novo limonoide de khaya senegalensis

    Energy Technology Data Exchange (ETDEWEB)

    Salles, Lis Regina V.O.; Silva, M. Fatima das G.F. da; Rodrigues Filho, Edson; Fernandes, Joao Batista; Vieira, Paulo C. [Sao Carlos Univ., SP (Brazil). Dept. de Quimica

    1995-12-31

    This work has dealt with the phyto chemical study of Kaya senegalensis. From the stem of Khaya senegalensis was isolated one novel limonoid, which was acetylated prior to analysis. Nuclear magnetic resonance techniques have been used to characterize and identify the compound and elucidate its stereochemistry. The placement of substituents at C-30{beta} and C-14{alpha} were established by NOESYTP experiments 5 refs., 4 tabs.

  11. Determination of Ra natural isotopes in marine samples from Itamaraca coastal regions; Determinacao de isotopos naturais de Ra em amostras costeiras da regiao de Itamaraca (PE)

    Energy Technology Data Exchange (ETDEWEB)

    Silveira, Patricia B.; Valentim, Eliane; Lima, Ricardo A. [Centro Regional de Ciencias Nucleares (CRCN), Recife, PE (Brazil)]. E-mail: pbrandao@cnen.gov.br; Medeiros, Carmem [Pernambuco Univ., Recife, PE (Brazil). Dept. de Oceanografia; Oliveira, Joselene [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil)

    2005-07-01

    Groundwater plays an important role in the transport of nutrients and pollutants to the coastal marine environment s and other surfaces water. Concentrations of {sup 223}Ra, {sup 224}Ra and {sup 226}Ra in marine water of the Itamaraca coastal region, PE, were measured during the winter of 2004, aiming to investigate the presence of radionuclides as a tracer of submarine groundwater discharges (SGD) in the environment studied. Measurements of temperature, salinity and nutrients were also carried out. (author)

  12. Methodology for determination of activity of radionuclides by gamma spectrometry; Metodologia para determinacao da atividade de radionuclideos por sistema de espectrometria gama

    Energy Technology Data Exchange (ETDEWEB)

    Fragoso, Maria da Conceicao de Farias; Oliveira, Victor Rogerio S. de; Oliveira, Mercia L.; Lima, Fernando Roberto de Andrade, E-mail: mariacc05@gmail.com [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-NE), Recife, PE (Brazil)

    2014-07-01

    Due to the growth in the number of procedures that make use of the positron emission tomography (PET), there is a need for standard solutions for the calibration of the systems used for the measurement of the PET radiopharmaceutical (activimeter) in radiopharmacies and in nuclear medicine services. Among the existing alternatives for the standardization of radioactive sources, the method known as gamma spectrometry is widely used for short-lived radionuclides. The purpose of this study was to implement the methodology for standardization of the {sup 18}F solutions by gamma spectrometry at the Regional Center for Nuclear Sciences of the Northeast (CRCN-NE/CNEN-NE), Brazil. (author)

  13. Determination of acoustoelastic constant in API-5L-X70 welded pipes; Determinacao da constante acustoelastica de tubos API-5L-X70 com solda

    Energy Technology Data Exchange (ETDEWEB)

    Bittencourt, Marcelo de Siqueira Queiroz; Fonseca, Manoel Antonio da Costa [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Oliveira, Carlos Henrique Francisco de [PETROBRAS S.A., Rio de de Janeiro, RJ (Brazil)

    2008-07-01

    To preserve the environment and avoid financial losses resulting from leaks in the transport of natural oil and gas the industry is particularly concerned to ensure the structural integrity of their pipelines. Grounded pipes may be exposed to damages due to unstable soil movement, and in extreme cases, to failure. Then, techniques to assess stress in pipelines are of central importance. The ultrasonic birefringence technique is an efficient method to measure residual stress. It is based on the changing velocity of the shear wave when it crosses a material under stress; this phenomenon is known as acoustoelasticity. The knowledge of the parameter called acoustoelastic constant is necessary to measure stress using this technique. By the mechanical conformation in the manufacture of welded tubes, from rolled plates, different anisotropy degrees are showed around the cross section of these tubes. In this paper it was studied the acoustoelastic constant for the API-5L-X70 steel pipes, with different thicknesses, diameters and manufacturing processes so as to be able to use this technique to stress measurement in pipelines. (author)

  14. Trace element determination study in human hair by neutron activation analysis; Estudo da determinacao de elementos traco em cabelos humanos pelo metodo de analise por ativacao com neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Frazao, Selma Violato

    2008-07-01

    Human hair analysis studies have been subject of continuous interest due to the fact that they can be used as an important tool to evaluate trace element levels in the human body. These determinations have been carried out to use hair for environmental and occupational monitoring, to identify intoxication or poisoning by toxic metals, to assess nutritional status, to diagnose and to prevent diseases and in forensic sciences. Although hair analysis presents several advantages over other human tissue or fluid analyses, such as organ tissue, blood, urine and saliva, there are some controversies regarding the use of hair analysis data. These controversies arise from the fact that it is difficult to establish reliable reference values for trace elements in hair. The purpose of this study was to evaluate the factors that affect element concentrations in hair samples from a population considered healthy and residing in the Sao Paulo metropolitan area. The collected human head hair was cut in small pieces, washed, dried and analyzed by neutron activation analysis (NAA). Aliquots of hair samples and synthetic elemental standards were irradiated at the IEA-R1 nuclear research reactor for 16 h under a thermal neutron flux of about 5x10{sup 12} n cm{sup -2} s{sup -1} for As, Br, Ca, Co, Cr, Cs, Cu, Fe, K, La, Na, Sb, Sc, Se and Zn determinations. The induced gamma activities of the standards and samples were measured using a gamma ray spectrometer coupled to an hiperpure Ge detector. For quality control of the results, IAEA- 85 Human Hair and INCT-TL-1 Tea Leaves certified reference materials (CRMs) were analyzed. Results obtained in these CRMs presented for most of elements, good agreement with the values of the certificates (relative errors less than 10%) and good precision (variation coefficients less than 13.6%). Results of replicate hair sample analysis showed good reproducibility indicating homogeneity of the prepared sample. Results obtained in the analyses of dyed and non-dyed hair showed that element adsorption or desorption occurs due to the dye. Analysis of hair samples collected from different regions of the head presented significant differences for the elements Fe, Sc, Se and Cr, indicating the importance of defining head regions for hair sample collection. Results of hair analysis from individuals residing in Sao Paulo metropolitan area showed individual differences for age, gender and natural hair color. Results obtained in this population also showed, that the mean element concentrations found are within the literature values. (author)

  15. Application of activation analysis for determination of some elements in cassiterite samples; Aplicacao da analise por ativacao para a determinacao de alguns elementos em amostras de cassiterita

    Energy Technology Data Exchange (ETDEWEB)

    Armelin, Maria Jose Aguirre

    1978-07-01

    This work consists in the development of an analytical method using activation by thermal neutrons for the determination of some minor elements and traces present in cassiterite (tin ore). This method was then applied to determine these elements in samples of cassiterite from different regions of Brazil. An analysis was made of the mineralogy characteristic of cassiterite as well as of the minerals most commonly associated with it. Four main types of interference were found to occur in the analysis by activation of trace elements in samples of cassiterite. The method involves the analysis without chemical separation for the determination of some elements and the analysis with chemical separation for the determination of other elements. The steps involved in both types of analysis are described. In the analysis with chemical separation the matrix element (tin) is separated by distillation in an H{sub 2}SO{sub 4}-HBr medium, after fusion of the ore with Na{sub 2}O{sub 2}. Arsine and antimony are determined in the distilled, whereas some lanthanide elements and uranium are determined in the distillation residue by separating them as a group by precipitation with lanthanum fluoride. A discussion on the precision, accuracy and sensibility of the method is also included. (author)

  16. Experimental determination of organic liquid fuels heating value as function of the humidity; Determinacao experimental do poder calorifico de combustiveis organicos liquidos em funcao da umidade

    Energy Technology Data Exchange (ETDEWEB)

    Lyrio, Aristoteles Alves; Dalvi, Elias Antonio; Vieira, Renata da Cruz Araujo [Espirito Santo Univ., Vitoria, ES (Brazil). Dept. de Engenharia Mecanica

    1998-07-01

    This work presents experimental results for higher heating value (HHV) and lower heating value (LHV) of organic liquid fuels sold in gas stations situated at Vitoria Metropolitan Area in the state of Espirito Santo, Brazil. Experiments were conduced showing the influence of fuel water contents on the HHV and LHV such as gasoline, diesel oil, kerosene and alcohol, covering a wide range of humidity (0 to 70%). A correlation between higher heating value and the water content in the fuel was determined for the experimental data obtained. The main conclusion of the present work has shown that the content of water in the fuel makes its higher heating value to decrease in the same proportion as the value of the humidity (ratio between mass of water and mass of fuel mass of water), and so, it is very important to control the level of humidity in the fuel in order to avoid significant losses of heat released during the fuel combustion. (author)

  17. Evaluation of dentifrice abrasion on human dentin and teeth enamel; Determinacao da abrasividade de dentifricios em dentina e esmalte de dentes humanos

    Energy Technology Data Exchange (ETDEWEB)

    Camargo, Iara M.C. de; Saiki, Mitiko; Vasconcellos, Marina B.A. [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil)

    1997-10-01

    Radiometric method is applied to the dentifrice abrasion indicators evaluation: radioactive dentin (RDA) and radioactive enamel abrasion (REA). The dentifrices analysed presented RDA values varying from 95 to 13 and REA values from 7.1 to 0.7, showing a good precision, generally with relative standard deviations lower than 15.4%. Also, the dentifrices were classified as having low and medium cleaning potential. A correlation between RDA and REA values was obtained, i.e. dentifrices with high RDA values presented high REA ones. (author). 6 refs., 3 tabs.

  18. Determination of crystallinity of ceramic materials from the Ruland Method; Determinacao da cristalinidade de materiais ceramicos atraves do metodo de Ruland

    Energy Technology Data Exchange (ETDEWEB)

    Kniess, C.T. [Universidade Nove de Julho (UNINOVE), SP (Brazil); Prates, P.B.; Gomes Junior, J.C.; Lima, J.C. de; Riella, H.G.; Kuhnen, N.C., E-mail: kniesscl@gmail.com, E-mail: patybp@gmail.com [Universidade Federal de Santa Catarina (UFSC), SC (Brazil)

    2011-07-01

    Some methods found in literature approach the different characteristics between crystalline and amorphous phases by X ray diffraction technique. These methods use the relation between the intensities of the crystalline peaks and background amorphous or the absolute intensity of one of these to determine the relative amount of crystalline and amorphous material. However, a crystalline substance presents shows coherent diffuse scattering and a loss in the intensity of the peaks of diffraction in function of thermal vibrations of atoms and imperfections in the crystalline structure. A correct method for the determination of the crystallinity must take in account these effects. This work has as objective to determine the crystallinity of ceramic materials obtained with the addition of mineral coal bottom ashes, using the X ray diffraction technique and the Ruland Method, that considers the diminution of the intensity of the crystalline peak because of the disorder affects. The Ruland Method shows adequate for the determination of the crystallinity of the ceramic materials. (author)

  19. Determining the amount of anhydrous alcohol evaporated in vertical cylindrical tanks; Determinacao da quantidade de alcool etilico anidro evaporado em tanques cilindricos verticais

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Elcio Cruz de [TRANSPETRO - PETROBRAS Transporte S.A., Rio de Janeiro, RJ (Brazil)

    2008-07-01

    In order to assess the anhydrous alcohol evaporated amount in vertical cylindrical tanks was developed a calculation methodology based on the rate of mass transfer of the product, the Reynolds number and the mass transfer coefficient. An Excel spreadsheet was prepared with data entry of the tank and physical and chemical properties of the product (temperature and density). For a temperature of 50 deg C, the volume evaporated reaches values of 0.8% by day. (author)

  20. Determination of threshold shear stress to drag particles in cuttings bed; Determinacao da tensao de cisalhamento minima para arraste de particulas em um leito fluidizado

    Energy Technology Data Exchange (ETDEWEB)

    Loureiro, Bruno Venturini; Siqueira, Renato do Nascimento [Faculdade do Centro Leste (UCL), Serra, ES (Brazil). Lab. de Fenomenos de Transporte], e-mail: brunovl@ucl.br, e-mail: renatons@ucl.br

    2006-07-01

    Drilling of horizontal wells for oil and gas production needs an efficient cleaning process due to settling of particles removed during the drilling process, which settles on the inferior part of the annular space between the drilling column and the walls of the well. The erosion of the bed is an important physical phenomenon to petroleum and gas industry since it can improve the opening of the wells. This work aims to estimate the threshold shear stress necessary to start the erosion process in a sediment bed. An experimental apparatus was built from simplifications of the problem in order to measure the flow rate and identify the beginning of the process. The experiment consists of a rectangular duct with aspect ratio ({lambda} = h/b) of 1/3 and non dimensional length (L{sup *} = L/h) of 75. The sediment bed to be eroded was placed at 60< x{sup *}<66. Using the flow rate and the boundary conditions, a discretization of the problem was carried out to permit a computational solution using the finite volume method and hence, determine the shear stress. This work used particles with up to 3.0 mm and modeled the flow considering a bed with equivalent roughness. (author)

  1. Multielementar determination by neutron activation in sediment samples from Tartarugalzinho region, Amapa State, Brazil; Determinacao multielementar em amostras de sedimentos da regiao do Tartarugalzinho, Amapa, por ativacao neutronica

    Energy Technology Data Exchange (ETDEWEB)

    Neri, Maria C.; Favaro, Debora I.T.; Vasconcellos, Marina B.A. [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil); Oliveira, Sonia M.B. de; Melfi, Adolfo J. [Sao Paulo Univ., SP (Brazil). Inst. de Geociencias; Fostier, Anne H. [Centro de Energia Nuclear na Agricultura (CENA), Piracicaba, SP (Brazil). Lab. de Quimica Analitica; Guimaraes, Jean R.D. [Universidade Federal, Rio de Janeiro, RJ (Brazil). Inst. de Biofisica; Forti, Maria C. [Instituto Nacional de Pesquisas Espaciais (INPE), Sao Jose dos Campos, SP (Brazil)

    1999-11-01

    In the present work, sediment samples collected in the Tartarugalzinho region, State of Amapa, were analyzed by instrumental neutron activation analysis. The concentration of the elements As, Ba, Br, Co, Cr, Cs, Fe, Na, Rb, Sc, Se, Ta, Th, U, Zn and Zr and the rare earth elements Ce, Eu, La, Lu, Nd, Sm, Tb and Yb could be determined. Analysis of the reference materials Buffalo River Sediment (NIST SRM 2704) and Soil 7 (IAEA) showed the accuracy and precision of the method. (author) 4 refs., 1 fig., 7 tabs.

  2. Determination voltage applied to an X-ray tube using the spectrum; Determinacao da tensao aplicada em um tubo de raios-X usando o espectro

    Energy Technology Data Exchange (ETDEWEB)

    Albuquerque, M.A.G.; David, M.G.; Almeida, Carlos Eduardo de; Magalhaes, Luis Alexandre Goncalves, E-mail: malbuqueque@hotmail.com [Universidade do Estado do Rio de Janeiro (UERJ), Rio de Janeiro, RJ (Brazil). Lab. de Ciencias Radiologicas; Peixoto, Guilherme [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    This work shows the methodology used to determine the voltage applied in an X-ray tube using their spectra. The measurements were made using a detector Cadmium telluride . Before the measurements are carried out detector was calibrated with a source of {sup 241}Am. After obtaining the spectra , the mean energies were calculated , the electron accelerating potential (k Vp ) of each spectrum is constructed a calibration straight for the kVp this tube. (author)

  3. Determination of relative efficiency of a detector using Monte Carlo method; Determinacao da eficiencia relativa de um detector usando metodo de Monte Carlo

    Energy Technology Data Exchange (ETDEWEB)

    Medeiros, M.P.C.; Rebello, W.F., E-mail: eng.cavaliere@ime.eb.br, E-mail: rebello@ime.eb.br [Instituto Militar de Engenharia (IME), Rio de Janeiro, RJ (Brazil). Secao de Engenharia Nuclear; Lopes, J.M.; Silva, A.X., E-mail: marqueslopez@yahoo.com.br, E-mail: ademir@nuclear.ufrj.br [Coordenacao dos Programas de Pos-Graduacao em Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Nuclear

    2015-07-01

    High-purity germanium detectors (HPGe) are mandatory tools for spectrometry because of their excellent energy resolution. The efficiency of such detectors, quoted in the list of specifications by the manufacturer, frequently refers to the relative full-energy peak efficiency, related to the absolute full-energy peak efficiency of a 7.6 cm x 7.6 cm (diameter x height) NaI(Tl) crystal, based on the 1.33 MeV peak of a {sup 60}Co source positioned 25 cm from the detector. In this study, we used MCNPX code to simulate an HPGe detector (Canberra GC3020), from Real-Time Neutrongraphy Laboratory of UFRJ, to survey the spectrum of a {sup 60}Co source located 25 cm from the detector in order to calculate and confirm the efficiency declared by the manufacturer. Agreement between experimental and simulated data was achieved. The model under development will be used for calculating and comparison purposes with the detector calibration curve from software Genie2000™, also serving as a reference for future studies. (author)

  4. Committed effective dose determination in cereal flours by gamma-ray spectrometry; Determinacao das doses efetivas por ingestao de farinhas de cereais atraves da espectrometria de raios gama

    Energy Technology Data Exchange (ETDEWEB)

    Scheibel, Viviane

    2006-07-01

    The health impact from radionuclides ingestion of foodstuffs was evaluated by the committed effective doses determined in commercial samples of South-Brazilian cereal flours (soy, wheat, corn, manioc, rye, oat, barley and rice flour). The radioactivity traces of {sup 228}Th, {sup 228}Ra, {sup 226}Ra, {sup 40}K, {sup 7}Be and {sup 137}Cs were measured by gamma-ray spectrometry employing a 66% relative efficiency HPGe detector. The energy resolution for the 1332.46 keV line of {sup 60}Co was 2.03 keV. The committed effective doses were calculated with the activities analyzed in the present flour samples, the foodstuff rates of consumption (Brazilian Institute of Geography and Statistics) and the ingestion dose coefficients (International Commission of Radiological Protection). The reliability median activities were verified with {chi}{sup 2} tests, assuring the fittings quality. The highest concentration levels of {sup 228}Th and {sup 40}K were 3.5 {+-} 0.4 and 1469 {+-} 17 Bq.kg{sup -1} for soy flour, respectively, with 95% of confidence level. The lower limit of detection for {sup 137}Cs ranged from 0.04 to 0.4 Bq.kg{sup -1}. The highest committed effective dose was 0.36 {mu}Sv.y{sup -1} for {sup 228}Ra in manioc flour (adults). All committed effective doses determined at the present work were lower than the UNSCEAR limits of 140 {mu}Sv.y{sup -1} and much lower than the ICRP (1991) limits of 1 mSv.y{sup -1}, for general public. There are few literature references for natural and artificial radionuclides in foodstuffs and mainly for committed effective doses. This work brings the barley flour data, which is not present at the literature and {sup 7}Be data which is not encountered in foodstuffs at the literature, besides all the other flours data information about activities and committed effective doses. (author)

  5. Methodology to determine the efficiency of a beta emitter gases monitor; Metodologia para determinacao da eficiencia de um monitor de gases emissores de particulas beta

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, Marcos Rodrigues de

    1995-07-01

    This work presents a methodology developed to determinate the efficiency of air monitors used to measure the concentration of beta emitters noble gases in nuclear power stations. Efficiency values, obtained by means of theoretical computation are compared with experimental values. The experimental part of the work was performed using three different point beta source, to simulate small amounts of gas uniformly distributed in small volume. The comparison shows that theoretical an experimental values agree within 4,2 % for {sup 90}Sr + {sup 90}Y, {sup 204}Tl and {sup 45}Ca beta sources. (author)

  6. Uncertainty analysis in the determination of absorbed dose in water by Fricke chemical dosimetry; Analise das incertezas na determinacao da dose absorvida na agua por dosimetria quimica Fricke

    Energy Technology Data Exchange (ETDEWEB)

    Vasconcelos, Fabia; Aguirre, Eder Aguirre, E-mail: fabiavasco@hotmail.com, E-mail: ederuni01@gmail.com [Fundacao do Cancer, Rio de Janeiro, RJ (Brazil); Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil)

    2016-07-01

    This work studies the calculations of uncertainties and the level of confidence that involves the process for obtaining the dose absorbed in water using the method of Fricke dosimetry, developed at Laboratorio de Ciencias Radiologicas (LCR). Measurements of absorbance of samples Fricke, irradiated and non-irradiated is going to use in order to calculate the respective sensitivity coefficients, along with the expressions of the calculation of Fricke dose and the absorbed dose in water. Those expressions are used for calculating the others sensitivity coefficients from the input variable. It is going to use the combined uncertainty and the expanded uncertainty, with a level of confidence of 95.45%, in order to report the uncertainties of the measurement. (author)

  7. Determination of high molecular mass compounds from Amazonian plant's leaves; Determinacao de compostos de massa molecular alta em folhas de plantas da Amazonia

    Energy Technology Data Exchange (ETDEWEB)

    Siqueira, Denilson Soares de; Pereira, Alberto dos Santos; Aquino Neto, Francisco Radler de [Universidade Federal, Rio de Janeiro, RJ (Brazil). Inst. de Quimica]. E-mail: ladetec@iq.gov.br; Cabral, Jose Augusto; Ferreira, Carlos Alberto Cid [Instituto Nacional de Pesquisas da Amazonia (INPA), Manaus, AM (Brazil); Simoneit, Bernd R.T. [Oregon State Univ., Corvallis, OR (United States). College of Oceanic and Atmospheric Sciences. Petroleum and Environmental Geochemistry Group; Elias, Vladimir O. [Analytical Solution, Rio de Janeiro, RJ (Brazil)

    2003-10-01

    The fractions of dichloromethane extracts of leaves from andiroba (Carapa guianensis - Meliaceae), caapi (Banisteriopsis caapi - Malpighiaceae), cocoa (Theobroma cacao - Sterculiaceae), Brazil nut (Bertholletia excelsa - Lecytidaceae), cupuacu (Theobroma grandiflorum - Sterculiaceae), marupa (Simaruba amara - Simaroubaceae) and rubber tree (Hevea brasiliensis - Euphorbiaceae), were analyzed by HT-HRGC and HT-HRGC-MS. Esters of homologous series of fatty acids and long chain alcohols, phytol, amyrines and tocopherols were characterized. The characterization of the compounds was based mainly in mass spectra data and in addition by usual spectrometric data ({sup 1}H and {sup 13}C NMR, IR). (author)

  8. A study on antimony determination in environmental samples by neutron activation analysis: validation of the methodology and determination of the uncertainty of the measurement; Estudo sobre a determinacao de antimonio em amostras ambientais pelo metodo de analise por ativacao com neutrons: validacao da metodologia e determinacao da incerteza da medicao

    Energy Technology Data Exchange (ETDEWEB)

    Matsubara, Tassiane Cristina Martins

    2011-07-01

    Antimony is an element found in low concentrations in the environment. However, its determination has attracted great interest due to the knowledge of its toxicity and increasing application in industry. The determination of antimony has been a challenge for researchers since this element is found in low concentrations which make its analysis a difficult task. Therefore, although neutron activation analysis (NAA) is an appropriate method for the determination of various elements in different types of matrix, in the case of Sb its analysis presents some difficulties, mainly due to spectral interferences. The objective of this research was to validate the NAA method for Sb determination in environmental samples. To establish appropriate conditions for Sb determinations, preliminary assays were carried out for further analysis of certified reference materials (CRM). The experimental procedure was to irradiate samples with a synthetic Sb standard for a period of 8 or 16 hours in the IEA-R1 nuclear research reactor, followed by gamma ray spectrometry. The quantification of Sb was performed by measuring the radioactive isotopes of {sup 122}Sb and '1{sup 24}Sb. The results of preliminary assays indicated the presence of Sb in Whatman no 40 filter paper used in the preparation of the synthetic standard, but at very low concentrations, which could be considered negligible. In the case of the plastic material used in bags for the sample irradiation, it should be chosen carefully, because depending on the thickness, they may contain Sb. The analyses of the stability of the diluted Sb standard solution showed no change in the Sb concentration within eight months after its preparation. Results obtained in the analysis of certified reference materials indicated the interference of {sup 76}As and also of {sup 134}Cs and {sup 152}Eu in the Sb determinations by measuring '1{sup 22}Sb, due to the proximity of the gamma ray energies. The high activity of '2{sup 4}Na can also mask the peak of {sup 122}Sb hindering its detection. The analysis of CRM indicated that the accuracy and precision of the results depend on the type of matrix analyzed, its concentration in the sample, radioisotope measured and of the decay time used for the measurements. The analysis of the components that contribute to the uncertainty of the Sb concentration indicated that the largest uncertainty contribution is given by statistical counting of the sample. The findings also showed that the value of combined standard uncertainty depends on the radioisotopes of Sb measured and the decay time used for counting. This study showed that NAA is a very adequate method for Sb determinations in environmental samples furnishing results with low uncertainty values. (author)

  9. Application of electron beam radiation for peat sterilization and suppression of microbe contaminants; Aplicacao da radiacao por feixe de eletrons como agente esterilizante de microorganismos em substrato turfoso

    Energy Technology Data Exchange (ETDEWEB)

    Tsai, David

    2006-07-01

    Inoculation of root nodule bacteria into legume seeds such as soybean [Glycine max. (L.)], common bean (Phaseolus vulgaris L.) and forage pasture has been effective and convenient as this simple procedure may introduce effective strains of Bradyrhizobium/Rhizobium into agricultural soils without a past history of successful cropping systems with the legume hosts. Peat-based substrates previously sterilized have been used for decades as bacteria carrier, protecting them from the prevailing harsh conditions in tropical soils and ensuring their survival with nutrient and protection against the soil antagonists. The Brazilian Government requires that all peat-based substrates must be gamma-sterilized from a cobalt-60 ({sup 60}Co) source, prior the introduction of the root nodule bacteria into the package. The recommendation is for a dose up to 50 kGy for an effective suppression of pathogens and saprophytes, in order to avoid competition among the substrate microbiota. Recently, the use of the electron beam (EB) accelerator has shown to be a new alternative for peat pre-sterilization, as this technique may promote reactive free-radicals which are efficient to suppress microbial contaminants. This fast technology is considered more environment and ecology friendly-sound than gamma radiation ({gamma}). The disadvantage of not reaching higher depth than gamma rays from {sup 60}Co must be considered, and attempts of optimizing the technique are crucial. This study compared both methods by using increasing rates of radiation by {sup 60}Co by the EB method - O, 10, 20, 30, 40 e 50 kGy in a commercial peat used for inoculants. Experimental data from days 7, 14, 21 and 28 days (growth period) and 150, 180 and 210 days (storage period) indicated high numbers of the strain Rhizobium tropici CM-01, labelled with gusA{sup +} (Study 1) and celB{sup +} (Study 2) from both eat-sterilizing techniques, reaching values above the minimum of 1x10{sup 8} cells g{sup -1} peat. At high rates

  10. Radiation conditions for computerized tomography: determination and comparison; Condicoes de radiacao para tomografia computadorizada: determinacao e comparacoes

    Energy Technology Data Exchange (ETDEWEB)

    Andrade, Lucio das Chagas de

    2016-07-01

    Radiology is the practice in which radiation beams, usually radiation X are used to produce an image of the human body in order to obtain a diagnosis, for example, to evaluate a pathological condition by computerized tomography (CT). Although the computerized tomography diagnostic potential is unquestionable, caution must be taken because the doses are almost always higher than the observed in conventional radiology procedures. The ionization chamber used for dosimetry in CT is a unsealed cylindrical chamber with 10 cm and 15 cm of sensitive length. A typical characteristics of this camera is its uniform response to radiation incident at all angles around its axis. The revised edition of IEC 61267 (2005) brought as an innovation the radiation conditions for computed tomography, RQT, that simulate non-attenuated beam and are used in special CT applications. This study aims to establish the necessary conditions to obtain radiation pattern beam computed tomography, RQT, and a calibration laboratory implementation for pencil ionization chambers used in the beam dosimetry produced by these scanners in the Metrology National Laboratory of Ionizing Radiation (LNMRI). In the implementation of RQT conditions we were found that the ratio of kerma rates in the air, with or without additional filtration equivalent to the first HVL (half-value layer), are in accordance with IEC 61267 (2005), which provides a range between 48.5% and 51.5% for each quality. The LNMRI characterized the radiation conditions of RQT series (IEC, 2005), obtaining a percentage of 49.6% for the RQT 8, 50% for the RQT 9 and 50,4% for the RQT 10. With the substitution of the total additional filtration RQT qualities, composed by Al + Cu and by a total filtration composed by copper (Cu) only, it can be seen the emergence of a similar RQT quality named Quality Copper Tomography - QCT. The results of the calibration, the RQT and QCT qualities, had expanded uncertainties with a confidence level 95.45%, less

  11. Consideração onsideração da não-linearidade física para as vigas de concreto armado, pelo procedimento refinado da NB1 = Consideration of physical non-linearity of reinforced concrete beams, using the NB1 refined procedure

    Directory of Open Access Journals (Sweden)

    Carlos Humberto Martins

    2008-01-01

    Full Text Available Este trabalho apresenta um estudo sobre análise de vigas de concreto armado em que a não-linearidade física para o material é implementada pelo procedimento refinado da NBR-6118. Este modelo considera a não-linearidade física do concreto armado via diagramas de momento x curvatura de uma seção transversal. O modelo de diagramamomento x curvatura apresentado pelos Comentários Técnicos da NBR-6118 - CT-301 do Ibracon (ABNT, 2003 utiliza a deformação média na armadura tracionada, onde se leva em conta a resistência do concreto tracionado entre fissuras (tension stiffening. Portanto, foiimplementado, em linguagem de programação Fortran Power Station, o procedimento dado pela norma para a contribuição do concreto tracionado entre fissuras. Para comprovar a validade do procedimento implementado, são realizados exemplos numéricos.This work presents a study on the analysis of reinforced concrete beams in which the physical non-linearity of the material isimplemented through the refined procedure in the Technical Comments of Brazilian code NBR-6118 - CT 301 / Ibracon. This model considers the physical non-linearity of the reinforced concrete through momentum-curvature diagrams of a cross-section. Themomentum-curvature diagram presented in the CT-301 (ABNT, 2003 uses medium deformation in the reinforcement, in which the tension stiffening of the reinforced concrete is taken into account. Using programming language Fortran Power Station, the expression given by the code for the contribution of the tension stiffening of the reinforced concrete was implemented. Finally, some results are presented to check the validity of the employed calculation process.

  12. Beam loading

    CERN Document Server

    Gamp, Alexander

    2013-01-01

    We begin by giving a description of the radio-frequency generator-cavity-beam coupled system in terms of basic quantities. Taking beam loading and cavity detuning into account, expressions for the cavity impedance as seen by the generator and as seen by the beam are derived. Subsequently methods of beam-loading compensation by cavity detuning, radio-frequency feedback and feedforward are described. Examples of digital radio-frequency phase and amplitude control for the special case of superconducting cavities are also given. Finally, a dedicated phase loop for damping synchrotron oscillations is discussed.

  13. Beam collimator

    CERN Multimedia

    1977-01-01

    A four-block collimator installed on a control table for positioning the alignment reference marks. Designed for use with SPS secondary beams, the collimator operates under vacuum conditions. See Annual Report 1976 p. 121 and photo 7701014.

  14. Evaluation of the uncertainty for the efficiency curve determination of {sup 210}Pb by liquid scintillation; Avaliacao da incerteza para a curva de eficiencia da determinacao de {sup 210}Pb por cintilacao liquida

    Energy Technology Data Exchange (ETDEWEB)

    Sampaio, C.S.; Sousa, W.O.; Dantas, B.M., E-mail: camilla@ird.gov.br [Instituto de Radioprotecao e Dosimetria, (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2014-07-01

    Methodologies for the evaluation of uncertainties associated with the determination of the efficiency curve of {sup 210}Pb by liquid scintillation counting (LSC) are presented. No statistical difference were found when compared the uncertainties of the curves that represented the counting net before and after the secular equilibrium between {sup 210}Pb and {sup 210}Bi, nether when compared the curves when counting only {sup 210}Pb and the curve with the total count of {sup 210}Pb and {sup 210}Bi, for the same time interval after precipitation. (author)

  15. Absolute activity measurement and gamma-ray emission probability for decay of I-126; Medida absoluta da atividade e determinacao da taxa de emissao gama por decaimento do {sup 126} I

    Energy Technology Data Exchange (ETDEWEB)

    Fonseca, Katia Aparecida

    1997-07-01

    The accurate knowledge of the gamma-ray emission probability per decay of radionuclides is important in several applications. In the case of {sup 126} I, its importance lies mainly in fast neutron dosimetry as well as in the production of {sup 125} I where {sup 126} I appears as an impurity. In the present work the gamma-ray emission probabilities per decay for the 388 and 666-KeV transitions of {sup 126} I have been measured. This radionuclide was obtained by means of the {sup 127} I(n, 2n){sup 126} I reaction in a fast neutron flux at the IPEN 2 MW research reactor. The methodology for the primary standardization of {sup 126} I is described. For this purpose, two different coincidence systems were used due to the complex decay scheme of this radionuclide. The {beta}branch measurement was carried out in a 4 {pi}(PC){beta}-{gamma} coincidence system consisting of a proportional counter, coupled to a pair of 3'x3' Na I (Tl) crystal. The electron capture branch was measured in a X-{gamma} coincidence system using two NaI(Tl) crystals. The gamma-ray measurements were performed in a HPGe system, previously calibrated by means of standard sources supplied by the International Atomic Energy Agency. All the uncertainties evolved were treated rigorously, by means of covariance analysis. (author)

  16. Combined discrete nebulization and microextraction process for molybdenum determination by flame atomic absorption spectrometry (FAAS); Avaliacao da combinacao da nebulizacao discreta e processos de microextracao aplicados a determinacao de molibdenio por espectrometria de absorcao atomica com chama (FAAS)

    Energy Technology Data Exchange (ETDEWEB)

    Oviedo, Jenny A.; Jesus, Amanda M.D. de; Fialho, Lucimar L.; Pereira-Filho, Edenir R., E-mail: erpf@ufscar.br [Universidade Federal de Sao Carlos (UFSCar), SP (Brazil). Departamento de Quimica

    2014-04-15

    Simple and sensitive procedures for the extraction/preconcentration of molybdenum based on vortex-assisted solidified floating organic drop microextraction (VA-SFODME) and cloud point combined with flame absorption atomic spectrometry (FAAS) and discrete nebulization were developed. The influence of the discrete nebulization on the sensitivity of the molybdenum preconcentration processes was studied. An injection volume of 200 μ resulted in a lower relative standard deviation with both preconcentration procedures. Enrichment factors of 31 and 67 and limits of detection of 25 and 5 μ L{sup -1} were obtained for cloud point and VA-SFODME, respectively. The developed procedures were applied to the determination of Mo in mineral water and multivitamin samples. (author)

  17. Determination of several elements in sediment samples from Nizao River basin, Dominican Republic by instrumental neutron activation analysis; Determinacao de diversos elementos em amostras de sedimento da bacia do Rio Nizao da Republica Dominicana por ativacao neutronica instrumental

    Energy Technology Data Exchange (ETDEWEB)

    Kastner, Geraldo Frederico; Vilhena Schayer Sabino, Claudia de [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN), Belo Horizonte, MG (Brazil)

    1995-12-31

    The Neutron Activation Laboratory at CDTN (Nuclear Technology Development Institute, Brazilian) (CNEN) has been acquiring through the years experience to determine several elements answering to analytical requests, including regional, national and international projects. Through neutron activation instrumental, gamma spectrometry and fission delayed neutron technique were analysed 50 samples of sediment from basin of Nizao River, Dominican Republic: Al, Fe, Mn, Na, Cr, Co, La, Sc, U and V with the objective to determine the concentration in both different parts: argil and sand. It was necessary to improve the irradiation conditions, delay time, counting, geometry and others proceedings due parameters like neutron flux, half life time of the radionuclide, gamma energies, all interfering in the procedures. The irradiations were carried about at IPR R1 TRIGA MARK I reactor. (author). 5 refs., 3 figs., 5 tabs.

  18. Precision of dual energy X-ray absorptiometry for body composition measurements in cats; Precisao da tecnica de absorciometria de raios-X de dupla energia na determinacao da composicao corporal em gatos

    Energy Technology Data Exchange (ETDEWEB)

    Borges, N.C. [Universidade Federal de Goias (UFG), Goiania, GO (Brazil). Escola de Veterinaria]. E-mail: naida@vet.ufg.br; Vasconcellos, R.S.; Canola, J.C.; Carciofi, A.C.; Pereira, G.T. [UNESP, Jaboticabal, SP (Brazil). Faculdade de Ciencias Agrarias e Veterinarias; Paula, F.J.A. [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina

    2008-07-01

    A short-term precision error of the individual subject and the DEXA technique, such as the effect of the repositioning of the cat on the examination table, were established. Four neutered adult cats (BW=4342 g) and three females (BW=3459 g) were submitted to five repeated scans with and without repositioning between them. Precision was estimated from the mean of the five measurements and expressed by the individual coefficient of variation (CV). The precision error of the technique was estimated by the variance of scan pool (n=35) and expressed in CV for the technique (CVt). The degrees of freedom and confidence intervals were determined to avoid underestimation of precision errors. Bone mineral content (BMC), lean mass (LM), and fat mass (FM) averages were higher (P<0.05) when animals were repositioned. The CVt was significantly higher (P<0.05) for bone mineral density (BMD), LM, and FM when the animals were repositioned. For short-term precision measurements, the repositioning of the animal was important to establish the precision of the technique. The dual energy xray absorptiometry method provided precision for body composition measurements in adult cats. (author)

  19. Problemas da sociologia da arte

    OpenAIRE

    Bastide, Roger

    2006-01-01

    A partir de um balanço das realizações consideradas pelo autor como as mais relevantes no campo da sociologia da arte até o final dos anos de 1940, o texto propõe novos rumos para a disciplina, considerando o modo como a arte é socialmente produzida como linguagem e valor.

  20. Radiation condition in computerized tomography (CT): determination and calibration of dosemeters; Condicoes de radiacao em tomografia computadorizada (TC): determinacao e calibracao de dosimetros

    Energy Technology Data Exchange (ETDEWEB)

    Adrade, L.C.; Peixoto, J.G.P., E-mail: lucio-andrade@hotmail.com [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2016-07-01

    RQT is the standard for radiation conditions in computed tomography . It simulates a beam unrelieved of a CT scanner . The camera pencil ionization dosimeter is used in CT. The LNMRI become known characterization of RQT radiation conditions and the secondary standard calibration for type pencil ionisation chambers in its lab. The obtained beam has the characteristics required by IEC 61267. The results of the calibration presented combined uncertainty expanded to 95.45% from 2.22% . (author)

  1. Stable beams

    CERN Multimedia

    2015-01-01

    Stable beams: two simple words that carry so much meaning at CERN. When LHC page one switched from "squeeze" to "stable beams" at 10.40 a.m. on Wednesday, 3 June, it triggered scenes of jubilation in control rooms around the CERN sites, as the LHC experiments started to record physics data for the first time in 27 months. This is what CERN is here for, and it’s great to be back in business after such a long period of preparation for the next stage in the LHC adventure.   I’ve said it before, but I’ll say it again. This was a great achievement, and testimony to the hard and dedicated work of so many people in the global CERN community. I could start to list the teams that have contributed, but that would be a mistake. Instead, I’d simply like to say that an achievement as impressive as running the LHC – a machine of superlatives in every respect – takes the combined effort and enthusiasm of everyone ...

  2. Effect of deposition distance on thickness and microstructure of silicon thin film produced by electron beam evaporation; Efeito da distancia de deposicao na espessura e microestrutura de filme fino obtido por evaporacao por feixe de eletrons

    Energy Technology Data Exchange (ETDEWEB)

    Toledo, T.F.; Ramanery, F.P.; Branco, J.R.T. [Fundacao Centro Tecnologico de Minas Gerais, Belo Horizonte, MG (Brazil)], e-mail: thalitaqui@yahoo.com.br; Cunha, M.A. [Acos Especiais Itabira S.A. (Acesita), Belo Horizonte, MG (Brazil)

    2006-07-01

    The interest for materials with new characteristics and properties made thin films an area of highest research interest. Silicon thin films have been widely used in solar cells, being the main active layer. In this work, the effect of deposition distance on thickness and microstructure of silicon films was investigated. The electron beam evaporation technique with argon plasma assistance was used to obtain films on stainless steel 304, Fe-Si alloy and soda lime glass. The experiments were made varying electron beam current and deposition pressure. The results are discussed based on Hertz-Knudsen's law and thin films microstructure evolution models. The samples were characterized by scanning electron microscopy, atomic force microscopy, X-ray diffraction and profilometer. (author)

  3. Pretreatment of sugarcane bagasse using the advanced oxidation process by electron beam for enzymatic hydrolysis of cellulose; Pre-tratamento do bagaco de cana utilizando o processo de oxidacao avancada por feixe de eletrons para hidrolise enzimatica da celulose

    Energy Technology Data Exchange (ETDEWEB)

    Ribeiro, Marcia Almeida

    2013-07-01

    The sugar cane bagasse is a renewable energy source and a raw material promise in the biofuel production, once represents about 30% of glucose contained in the plant with the potential to be hydrolyzed and then converted to ethanol. The bagasse is composed of cellulose, straight chain of glucose, of hemicellulose, an amorphous polymer consisting of xylose, arabinose, galactose, and mannose, and of lignin, a complex polymer consisting of fenilpropan units that acts as waterproof coating on the fibers, which is hard to remove due its recalcitrant nature. The aim of this work was to study the electron beam processing as a pretreatment of sugarcane bagasse to enzymatic hydrolysis of cellulose. The pretreatment of sugarcane bagasse is one of the most important steps to make this material economically viable and competitive on the energy production. As a pretreatment the electron beam processing can weak the hemicellulose and lignin structures by the action highly reactive radicals that breaks the links, reducing the degree of polymerization fibers. It was evaluated the chemical and structural modifications on fibers caused by the irradiation, the enzymatic hydrolysis of electron beam as the only pretreatment and combined to steam explosion. For enzymatic hydrolysis it was used the commercial enzymes from Novozymes. The radiation processing promotes changes in structure and composition of sugarcane bagasse, increasing the solubility, that is related to hemicellulose and cellulose cleavage, and also increasing the enzymatic conversion yield. In the case of exploded bagasse there is no changes in the enzymatic hydrolysis yield, however the electron beam processing promoted a 67% reduction of furfural, that is formed in the steam explosion process. (author)

  4. Evaluation of the response of thermoluminescent detectors in clinical beams dosimetry using different phantoms; Avaliacao da resposta de detectores termoluminescentes na dosimetria de feixes clinicos utilizando diferentes objetos simuladores

    Energy Technology Data Exchange (ETDEWEB)

    Matsushima, Luciana Cardoso

    2010-07-01

    Radiotherapy is one of the three principal treatment modalities used in the treatment of malignant diseases such as cancer, the other two are chemotherapy and radiosurgery. In contrast to other medical specialties that rely mainly on the clinical knowledge and experience of medical specialists, radiotherapy, with its use of ionizing radiation in treatment of cancer, relies heavily on modern technology and the collaborative efforts of several professionals whose coordinated team approach greatly influences the outcome of the treatment. In the area of clinical dosimetry, an efficient and accurate calibration of the radiation beam ensures knowledge of the radiation dose delivered to the patient, allowing thus the success of radiotherapy. This study aims to compare the thermoluminescent response of calcium sulfate doped with dysprosium (CaSO{sub 4}:Dy) dosimeters produced by IPEN (6 mm in diameter and 0,8 mm tick) with the response of lithium fluoride (3,15 x 3,15 x 0,9 mm{sup 3}) doped with magnesium and titanium (LiF:Mg,Ti) in dosimetry of clinical photons (6 and 15 MV) and electrons beams (6 and 9 MeV) using solid water (RMI-457), water and PMMA phantoms. Initially, the dose-response curves were obtained for irradiation in cobalt-60 gamma radiation source in air (PMMA plates) and under electronic equilibrium conditions and for clinical electrons and photons beams at depth of maximum dose. The sensitivities of the thermoluminescent dosimeters were also evaluated and the values of their reproducibilities and intrinsic efficiency were determined for the response to different types of phantoms and radiation energy. The obtained results indicate that the main advantage of CaSO{sub 4}:Dy dosimeters is the enhanced sensitivity to radiation doses measured for {sup 60}Co, photons and electrons beams, thus representing a viable alternative for application in dosimetry in the radiotherapy area. (author)

  5. Assessment of toxicity and genotoxicity of the reactive azo dyes Remazol Black B and Remazol Orange 3R and effectiveness of electron beam irradiation in the reduction of color and toxic effects; Avaliacao da toxicidade e genotoxicidade dos corantes azo reativos Remazol Preto B e Remazol Alaranjado 3R e da eficacia da radiacao com feixe de eletrons na reducao da cor e efeitos toxicos

    Energy Technology Data Exchange (ETDEWEB)

    Pinheiro, Alessandro de Sa

    2011-07-01

    The textile industries play an important role in national and global economy. But, their activities are considered potentially polluting. The use of large volumes of water and the production of colored wastewater with high organic matter are among the main issues raised, especially during the stage of dyeing and washing of the textile process. The reactive azo dyes are the main colors used in the industry for dyeing of cotton in Brazil and worldwide. Because of its low setting and variations in the fiber production process, about 30% of the initial concentration used in the dyeing baths are lost and will compose the final effluent. These compounds have a low biodegradability, are highly soluble in water and therefore are not completely removed by conventional biological processes. In addition, other processes do not promote degradation but the transference to solid environment. The dyes discarded without treatment in the water body can cause aesthetic modifications, alter photosynthesis and gas solubility, as well as being toxic and genotoxic. The main objectives of this study were to evaluate the toxicity and genotoxicity of two reactive azo dyes (Remazol Black B - RPB and Remazol Orange 3R - R3AR) and the percentage of color and toxicity reduction after the use of electron beam radiation. The acute toxicity assays performed with Vibrio fischeri, Daphnia similis and Biomphalaria glabrata showed different response patterns for dyes. The different chemical forms of dyes were slightly toxic to Vibrio fischeri and only the RPB dye (vinylsulphone) was toxic (EC50{sub 15min} = 6,23 mg L-1). In tests with Daphnia similis, the dye RPB was slightly toxic in its pattern form, sulphatoethylsulphone, (CE50{sub 48h} = 91,25 mg L{sup -1}) and showed no toxicity in other chemical forms. However, the RA3R dye was toxic to the dafnids and the vinylsulphone form very toxic (EC50{sub 48h} = 0,54 mg L-1). No toxicity was observed in Biomphalaria glabrata assays. Chronic toxicity was

  6. Beam-beam effects in the Tevatron

    Energy Technology Data Exchange (ETDEWEB)

    Shiltsev, V.; Alexahin, Y.; Lebedev, V.; Lebrun, P.; Moore, R.S.; Sen, T.; Tollestrup, A.; Valishev, A.; Zhang, X.L.; /Fermilab

    2005-01-01

    The Tevatron in Collider Run II (2001-present) is operating with 6 times more bunches, many times higher beam intensities and luminosities than in Run I (1992-1995). Electromagnetic long-range and head-on interactions of high intensity proton and antiproton beams have been significant sources of beam loss and lifetime limitations. We present observations of the beam-beam phenomena in the Tevatron and results of relevant beam studies. We analyze the data and various methods employed in operations, predict the performance for planned luminosity upgrades, and discuss ways to improve it.

  7. Beam imaging sensor

    Energy Technology Data Exchange (ETDEWEB)

    McAninch, Michael D.; Root, Jeffrey J.

    2016-07-05

    The present invention relates generally to the field of sensors for beam imaging and, in particular, to a new and useful beam imaging sensor for use in determining, for example, the power density distribution of a beam including, but not limited to, an electron beam or an ion beam. In one embodiment, the beam imaging sensor of the present invention comprises, among other items, a circumferential slit that is either circular, elliptical or polygonal in nature.

  8. Determination of the equivalent of environmental dose, H*(d), in a radiotherapy installation; Determinacao do equivalente de dose ambiental, H*(d), em uma instalacao de radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Lima, M.A.F.; Borges, J.C. [Universidade Federal de Rio de Janeiro, PEN/COPPE/UFRJ Caixa Postal 68509 21945-970, Rio de Janeiro (Brazil); Mota, H.C. [Instituto de Radio Protecao e Dosimetria, IRD/CNEN Caixa Postal 37750 22780-160, Rio de Janeiro (Brazil)

    1998-12-31

    In order to put into practice radiological protection has been required conversion factors for environmental dose equivalent determination to air kerma value for different kinds of photon and electron beams, such dose values have been determined in a spheric phantom of 30 cm diameter in a alignment field and expanded in a depth of this sphere. Details will be given for determining of equivalent dose distribution calculation using Monte Carlo computational method (ESG4) following the recommendations of ICRU. (Author)

  9. Ultracold ordered electron beam

    Energy Technology Data Exchange (ETDEWEB)

    Habs, D.; Kramp, J.; Krause, P.; Matl, K.; Neumann, R.; Schwalm, D.

    1988-01-01

    We have started an experimental program to develop an ultracold electron beam, which can be used together with a standard electron cooling device in the Heidelberg Test Storage Ring TSR. In contrast to the standard-type design using electron beam extraction beam extraction from a heated cathode, the ultracold beam is produced by photoemission of electrons from a cooled semiconductor crystal irradiated with an intense near-infrared laser light beam. Adiabatic acceleration is expected to provide ordering of the electron beam itself. Besides the cooling of ion beams to extremely low temperatures, with the aim of obtaining crystallization, the ultracold beam will constitute an excellent target for atomic physics experiments.

  10. Study of radiation detectors response in standard X, gamma and beta radiation standard beams; Estudo da resposta de monitores de radioprotecao em feixes padronizados de radiacao X, gama e beta

    Energy Technology Data Exchange (ETDEWEB)

    Nonato, Fernanda Beatrice Conceicao

    2010-07-01

    The response of 76 Geiger-Mueller detectors, 4 semiconductor detectors and 34 ionization chambers were studied. Many of them were calibrated with gamma radiation beams ({sup 37}Cs and {sup 60}Co), and some of them were tested in beta radiation ({sup 90}Sr+{sup 9'}0Y e {sup 204}Tl) and X radiation (N-60, N-80, N-100, N-150) beams. For all three types of radiation, the calibration factors of the instruments were obtained, and the energy and angular dependences were studied. For beta and gamma radiation, the angular dependence was studied for incident radiation angles of 0 deg and +- 45 deg. The curves of the response of the instruments were obtained over an angle interval of 0 deg to +- 90 deg, for gamma, beta and X radiations. The calibration factors obtained for beta radiation were compared to those obtained for gamma radiation. For gamma radiation, 24 of the 66 tested Geiger-Mueller detectors presented results for the energy dependence according to international recommendation of ISO 4037-2 and 56 were in accordance with the Brazilian ABNT 10011 recommendation. The ionization chambers and semiconductors were in accordance to national and international recommendations. All instruments showed angular dependence less than 40%. For beta radiation, the instruments showed unsatisfactory results for the energy dependence and angular dependence. For X radiation, the ionization chambers presented results for energy dependence according to the national recommendation, and the angular dependence was less than 40%. (author)

  11. Optical signal response pf the alanine gel solution for photons and electrons clinical beams;Resposta espectrofotometrica da solucao gel de alanina para feixes clinicos de fotons e eletrons

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Cleber Feijo; Campos, Leticia Lucente [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2009-07-01

    Alanine gel dosimeter is a new gel material developed at IPEN that presents significant improvement on previous alanine systems developed by Costa (1994). The measure technique is based on the transformation of ferrous ions (Fe{sup 2+}) in ferric ions (Fe{sup 3+}) after irradiation. The DL-Alanine (C{sub 3}H{sub 7}NO{sub 2}) is an aminoacid tissue equivalent that improves the production of ferric ions in the solution. This work aims to study the comparison of optical signal response of the alanine gel solution for photons and electrons clinical beams. It was observed that the calibration factor can be considered independent of quality of the radiation for photons and electrons clinical beams. Therefore, it can be used the same calibration factor for evaluating the absorbed dose in photons and electrons fields in the energy of 6 MeV. Alanine Gel Dosimeter presents good performance and can be useful as alternative dosimeter in the radiotherapy area using MRI technique for 3D dose distribution evaluation. (author)

  12. Construction of a laboratory for the implantation of primary standardization of the magnitude kerma in the air for the X-ray beams used in mammography; Construcao de um laboratorio para a implantacao da padronizacao primaria da grandeza kerma no ar para os feixes de raios X empregados em mamografia

    Energy Technology Data Exchange (ETDEWEB)

    Cardozo, W.L.; Magalhes, L.A.A.M.F.; Peixoto, J.G.P., E-mail: wagnerlc@ird.gov.b [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Lab. Nacional de Metrologia das Radiacoes Ionizantes (LNMRI)

    2009-07-01

    Aiming to diminish the uncertainty in each phase of the metrological chain, and the uncertainty in dosimetry processed at the X-ray beam applied in the mammography, is necessary that the LNMRI/IRD to develop a reference primary standard for the absolute form to the magnitude kerma in the air

  13. Numerical analysis of parasitic crossing compensation with wires in DA$\\Phi$NE

    CERN Document Server

    Valishev, A; Milardi, C; Zobov, M

    2015-01-01

    Current bearing wire compensators were successfully used in the 2005-2006 run of the DA{\\Phi}NE collider to mitigate the detrimental effects of parasitic beam-beam interactions. A marked improvement of the positron beam lifetime was observed in machine operation with the KLOE detector. In view of the possible application of wire beam-beam compensators for the High Luminosity LHC upgrade, we revisit the DA{\\Phi}NE experiments. We use an improved model of the accelerator with the goal to validate the modern simulation tools and provide valuable input for the LHC upgrade project.

  14. Beam Stop for Electron Accelerator Beam Characterisation

    Science.gov (United States)

    Roach, Greg; Sharp, Vic; Tickner, James; Uher, Josef

    2009-08-01

    Electron linear accelerator applications involving the generation of hard X-rays frequently require accurate knowledge of the electron beam parameters. We developed a beam stop device which houses a tungsten Bremsstrahlung target and enables the electron beam current, energy and position to be monitored. The beam stop consisted of four plates. The first was a removable aluminium (Al) transmission plate. Then followed the tungsten target. Behind the target there were four Al quadrant plates for beam position measurement. The last plate was a thick Al back-stop block. Currents from the four quadrants and the back-stop were measured and the beam lateral position, energy and current were calculated. The beam stop device was optimised using Monte-Carlo simulation, manufactured (including custom-made electronics and software) in our laboratory and tested at the ARPANSA (Australian Radiation Protection and Nuclear Safety Agency) linear accelerator in Melbourne. The electron beam energy was determined with a precision of 60 keV at beam energies between 11 and 21 MeV and the lateral beam position was controlled with a precision of 200 mum. The relative changes of the beam current were monitored as well.

  15. Electron beam control for barely separated beams

    Science.gov (United States)

    Douglas, David R.; Ament, Lucas J. P.

    2017-04-18

    A method for achieving independent control of multiple beams in close proximity to one another, such as in a multi-pass accelerator where coaxial beams are at different energies, but moving on a common axis, and need to be split into spatially separated beams for efficient recirculation transport. The method for independent control includes placing a magnet arrangement in the path of the barely separated beams with the magnet arrangement including at least two multipole magnets spaced closely together and having a multipole distribution including at least one odd multipole and one even multipole. The magnetic fields are then tuned to cancel out for a first of the barely separated beams to allow independent control of the second beam with common magnets. The magnetic fields may be tuned to cancel out either the dipole component or tuned to cancel out the quadrupole component in order to independently control the separate beams.

  16. Beam Techniques - Beam Control and Manipulation

    Energy Technology Data Exchange (ETDEWEB)

    Minty, Michiko G

    2003-04-24

    We describe commonly used strategies for the control of charged particle beams and the manipulation of their properties. Emphasis is placed on relativistic beams in linear accelerators and storage rings. After a brief review of linear optics, we discuss basic and advanced beam control techniques, such as transverse and longitudinal lattice diagnostics, matching, orbit correction and steering, beam-based alignment, and linac emittance preservation. A variety of methods for the manipulation of particle beam properties are also presented, for instance, bunch length and energy compression, bunch rotation, changes to the damping partition number, and beam collimation. The different procedures are illustrated by examples from various accelerators. Special topics include injection and extraction methods, beam cooling, spin transport and polarization.

  17. Literature in Focus Beta Beams: Neutrino Beams

    CERN Multimedia

    2009-01-01

    By Mats Lindroos (CERN) and Mauro Mezzetto (INFN Padova, Italy) Imperial Press, 2009 The beta-beam concept for the generation of electron neutrino beams was first proposed by Piero Zucchelli in 2002. The idea created quite a stir, challenging the idea that intense neutrino beams only could be produced from the decay of pions or muons in classical neutrino beams facilities or in future neutrino factories. The concept initially struggled to make an impact but the hard work by many machine physicists, phenomenologists and theoreticians over the last five years has won the beta-beam a well-earned position as one of the frontrunners for a possible future world laboratory for high intensity neutrino oscillation physics. This is the first complete monograph on the beta-beam concept. The book describes both technical aspects and experimental aspects of the beta-beam, providing students and scientists with an insight into the possibilities o...

  18. Elaboration and implementation of standard operational procedure for quality assurance of cone beam CT image in radiotherapy; Elaboracao e implementacao de procedimentos operacionais padrao para controle de qualidade da imagem CBCT em radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Bonatto, Larisse N.; Estacio, Daniela R.; Lopes, Juliane S.; Sansson, Angela; Duarte, Lucas O.; Sbaraini, Patricia; Silva, Ana M. Marques da; Streck, Elaine E., E-mail: larisse.neumann@pucrs.br [Pontificia Universidade Catolica do Rio Grande do Sul (PUC-RS), Porto Alegre, RS (Brazil)

    2016-07-01

    The objective of this article is to present the implementation of the quality Control of Cone Beam Computed Tomography (CBCT) image, generated by the On-Board Imager, integrated with the linear accelerator Trilogy. Standard operating procedures (POPs) have been developed based on the literature and manuals of the simulator object Catphan 504 and the On-Board Imager. The following POPs were developed: acquisition of the CBCT image; linearity of CT number; uniformity; spatial resolution; low contrast resolution; spatial linearity; thickness of the cut. The validation of the elaborated procedures was done from an experimental acquisition of the simulator object. The results obtained in the validation of the POPs are in compliance with the parameters established by the manufacturer of the simulator object, as well as those obtained in the acceptance of the On-Board Imager device.

  19. Telecommunication using muon beams

    Science.gov (United States)

    Arnold, Richard C.

    1976-01-01

    Telecommunication is effected by generating a beam of mu mesons or muons, varying a property of the beam at a modulating rate to generate a modulated beam of muons, and detecting the information in the modulated beam at a remote location.

  20. ISR beam scrapers

    CERN Multimedia

    1972-01-01

    Beam scrapers seen in the direction of the beam. The two horizontal scraper foils are near the centre of the beam pipe andthe two scrapers for protection of the vacuum chamber are further outside. In the lower part of the beam pipe is the vertical halo scraping blade.

  1. Ultracold Ordered Electron Beam

    Science.gov (United States)

    Habs, D.; Kramp, J.; Krause, P.; Matl, K.; Neumann, R.; Schwalm, D.

    1988-01-01

    We have started an experimental program to develop an ultracold electron beam, which can be used together with a standard electron cooling device in the Heidelberg Test Storage Ring TSR. In contrast to the standard-type design using electron beam extraction from a heated cathode, the ultracold beam is produced by photoemission of electrons from a cooled semiconductor crystal irradiated with an intense near-infrared laser light beam. Adiabatic acceleration is expected to provide ordering of the electron beam itself. Besides the cooling of ion beams to extremely low temperatures, with the aim of obtaining crystallization, the ultracold beam will constitute an excellent target for atomic physics experiments.

  2. The beam dump tunnels

    CERN Multimedia

    Patrice Loïez

    2002-01-01

    In these images workers are digging the tunnels that will be used to dump the counter-circulating beams. Travelling just a fraction under the speed of light, the beams at the LHC will each carry the energy of an aircraft carrier travelling at 12 knots. In order to dispose of these beams safely, a beam dump is used to extract the beam and diffuse it before it collides with a radiation shielded graphite target.

  3. Parabolic scaling beams.

    Science.gov (United States)

    Gao, Nan; Xie, Changqing

    2014-06-15

    We generalize the concept of diffraction free beams to parabolic scaling beams (PSBs), whose normalized intensity scales parabolically during propagation. These beams are nondiffracting in the circular parabolic coordinate systems, and all the diffraction free beams of Durnin's type have counterparts as PSBs. Parabolic scaling Bessel beams with Gaussian apodization are investigated in detail, their nonparaxial extrapolations are derived, and experimental results agree well with theoretical predictions.

  4. Effects of gamma radiation and electron beam on samples of the Brazil nuts artificially inoculated with Aspergillus flavus; Efeitos da radiacao gama e feixe de eletrons sobre amostras de castanhas-do-Brasil inoculadas artificialmente com Aspergillus flavus

    Energy Technology Data Exchange (ETDEWEB)

    Coelho, Ednei Assuncao Antunes

    2012-07-01

    The high level of contamination by aflatoxin produced by fungi in lots of Brazil nuts and the strict control by importing countries in relation to the levels of toxins in food, European Union countries decided in 2003 by the return of these lots products from Brazil. Despite the economic loss represented by contamination by toxigenic fungi in Brazil nuts, a major product of extractive Northern of Brazil, studies are still preliminary as the control of contamination aflatoxigenic fungal using methods such as gamma radiation (G.R) and mainly, electron beam (E.B). These facts motivated this research, which aimed to evaluate the effects of gamma radiation and application of electron beam in samples of Brazil nut artificially inoculated with Aspergillus flavus. This goal, we were studied 50 samples of the Brazil nut previously inoculated with spores of A. flavus and subsequently incubated at 30 °C in relative humidity controlled at 93%. After incubation, period of 15 days, the average water activity of the samples was 0.80, the samples were divided into 5 groups that received the following doses of radiation: control (0 kGy), 5 and 10 kGy 5 E.B and G.R. The mycobiota was performed by serial dilution, plated on surface using potato dextrose agar. The results demonstrated that treatment with E.B using a dose of 5 kGy and 10 kGy resulted in reduced growth of A. flavus in 74% (37/50) and 94% (47/50) of samples. The samples treated with G.R at the dose of 5 kGy and 10 kGy no fungal growth occurred in 92% (46/50) 100% (50/50) of. The study of aflatoxins showed that doses of E.B of 5 kGy and 10 kGy reduced levels of AFB1 at 53.32% and 65.66% respectively. The application of gamma rays at doses of 5 and 10 kGy reduced levels of toxins in 70.61% and 84.15% respectively. This result may be attributed to higher penetrability of gamma radiation. Sensory analysis showed greater acceptance of the judges for the samples irradiated with E.B and G.R at the dose of 10 kGy. We concluded

  5. Study of energy dependence of a extrapolation chamber in low energy X-rays beams; Estudo da dependencia energetica de uma camara de extrapolacao em feixes de raios-X de baixa energia

    Energy Technology Data Exchange (ETDEWEB)

    Bastos, Fernanda M.; Silva, Teogenes A. da, E-mail: fernanda_mbastos@yahoo.com.br, E-mail: silvata@cdtn.br [Centro de Desenvolvimeto da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2014-07-01

    This work was with the main objective to study the energy dependence of extrapolation chamber in low energy X-rays to determine the value of the uncertainty associated with the variation of the incident radiation energy in the measures in which it is used. For studying the dependence of energy, were conducted comparative ionization current measurements between the extrapolation chamber and two ionization chambers: a chamber mammography, RC6M model, Radcal with energy dependence less than 5% and a 2575 model radioprotection chamber NE Technology; both chambers have very thin windows, allowing its application in low power beams. Measurements were made at four different depths of 1.0 to 4.0 mm extrapolation chamber, 1.0 mm interval, for each reference radiation. The study showed that there is a variable energy dependence on the volume of the extrapolation chamber. In other analysis, it is concluded that the energy dependence of extrapolation chamber becomes smaller when using the slope of the ionization current versus depth for the different radiation reference; this shows that the extrapolation technique, used for the absorbed dose calculation, reduces the uncertainty associated with the influence of the response variation with energy radiation.

  6. Beam diagnostics for low energy beams

    Directory of Open Access Journals (Sweden)

    J. Harasimowicz

    2012-12-01

    Full Text Available Low-energetic ion and antimatter beams are very attractive for a number of fundamental studies. The diagnostics of such beams, however, is a challenge due to low currents down to only a few thousands of particles per second and significant fraction of energy loss in matter at keV beam energies. A modular set of particle detectors has been developed to suit the particular beam diagnostic needs of the ultralow-energy storage ring (USR at the future facility for low-energy antiproton and ion research, accommodating very low beam intensities at energies down to 20 keV. The detectors include beam-profile monitors based on scintillating screens and secondary electron emission, sensitive Faraday cups for absolute intensity measurements, and capacitive pickups for beam position monitoring. In this paper, the design of all detectors is presented in detail and results from beam measurements are shown. The resolution limits of all detectors are described and options for further improvement summarized. Whilst initially developed for the USR, the instrumentation described in this paper is also well suited for use in other low-intensity, low-energy accelerators, storage rings, and beam lines.

  7. Applicability of a prototype for determination of absorbed dose using brachytherapy equipment with Ir-192 sources; Aplicabilidade de um prototipo para determinacao da dose absorvida utilizando equipamentos de braquiterapia com fontes de IR-192

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Vivianne Lucia Bormann; Almeida, Mayara Gabriella Oliveira de; Vieira, Rafaela Etelvina de Amorim; Silva, Waldecy Ananias da; Nascimento, Rizia Keila, E-mail: vlsouza@cnen.gov.br, E-mail: mayaradqf@hotmail.com, E-mail: rodriguesss@hootmail.com, E-mail: waldecy@cnen.gov.br, E-mail: riziakeila@hotmail.com [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil)

    2014-07-01

    This work aims at the development and improvement of a device to perform the absolute dosimetry sources of Ir-192 using the Fricke solution contained in a flask. The Fricke solution used was prepared using amounts of ferrous ammonium sulfate, sodium chloride and sulfuric acid, diluted with water tri distilled pre-established in the literature. The spectrophotometer used was a UV-VIS spectrophotometer (Beckman DU-640 Counter) for measuring the optical density at wavelength 304 nm. The calculation for determining the radial dose takes into account the radial distance and the angle formed with the transverse axis of the source. As the results obtained can be seen that the states of Pernambuco, Ceara, Paraiba e Piaui are in accordance with the recommendations of international standards of the International Atomic Energy Agency (IAEA), which considers not acceptable a difference greater than 5% of prescribed dose and measured dose.

  8. Preliminary tests to determine the fatigue curve of the Ibis ACSR (Aluminum Cable Steel Reinforced) conductor; Ensaios preliminares para determinacao da curva de fadiga do cabo condutor ACSR Ibis

    Energy Technology Data Exchange (ETDEWEB)

    Rosa, Daniel M. [Universidade de Brasilia (UnB-Gama), DF (Brazil)], E-mail: danielrosa@unb.br; Fadel, Aida A.; Araujo, Jose Alexander; Ferreira, Jorge Luiz A.; Henriques, Antonio Manoel D. [Universidade de Brasilia (EnM/UnB), DF (Brazil). Dept. de Engenharia Mecanica], Emails: aida@unb.br, alex07@unb.br, jorge@unb.br, Henriques@unb.br; Hortencio, Tania M.O.S. [Companhia Energetica de Goias Distribuicao S.A. (CELG D), Goiania, GO (Brazil)], E-mail: tania.hortencio@celg.com.br

    2009-07-01

    The aim of this work was to present a fretting fatigue experimental rig for overhead conductors and to carry out a set of experiments to obtain life estimative for a standard Ibis ACSR, Aluminium Conductor Steel Reinforced. A preliminary S-N (Wohler) Curve was obtained in the medium high cycle fatigue regime. Experiments considered the occurrence of at least two wire breaks to obtain each point of the S-N curve, which was compared to CIGRE's Safe Border Line (CSBL). The experimental results showed five to ten times large lives than the ones provided by CSBL adoption. (author)

  9. Determination of the zero point of charge of kaolin waste from the Northeast of Para, BR; Determinacao do ponto de carga zero de residuo de caulim da regiao nordeste do Para

    Energy Technology Data Exchange (ETDEWEB)

    Pinto, R.L.S.; Maia, R.F.S.; Felipe, A.M.P.F., E-mail: rayssa.luana@hotmail.com [Universidade Federal do Para (UFPA), Belem, PA (Brazil). Instituto de Tecnologia. Faculdade de Engenharia Quimica. Laboratorio de Reologia

    2012-07-01

    The Para contributes with more than 50% of national production of kaolin of which 12.5% correspond to the waste generated, which has similar composition to benefited kaolin, can be used as adsorbent of heavy metals. The viscosity influences the design of equipment that can reuse that waste. The pH changes the pulp viscosity and the determination of the zero point of charge can estimate this variation. This study analyzes the influence of pH on the pulp rheology by the determination of the zero point of charge. Tests were made by Scanning Electron Microscopy, Energy Dispersive Spectroscopy, potentiometric titulation and rheological analysis. The results showed zero point of charge equal to 3.7 and confirmed that the viscosity increase at pH values near the zero point of charge and decrease at pH values away from this. (author)

  10. Determination of thermal diffusivity of dental enamel and dentin as a function of temperature, using infrared thermography; Determinacao da difusividade termica do esmalte e dentina em funcao de temperatura, utilizando termografia no infravermelho

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, Thiago Martini

    2009-07-01

    In this work it was developed a software that calculates automatically, the thermal diffusivity value as a function of temperature in materials. The infrared thermography technique was used for data acquisition of temperature distribution as a function of time. These data were used to adjust a temperature function obtained from the homogeneous heat equation with specific boundary conditions. For that, an infrared camera (detecting from 8 {mu}m to 9 {mu}m) was calibrated to detect temperature ranging from 185 degree C up to 1300 degree C at an acquisition rate of 300 Hz. It was used, 10 samples of dental enamel and 10 samples of dentin, with 4 mm x 4 mm x 2 mm, which were obtained from bovine lower incisor teeth. These samples were irradiated with an Er:Cr:YSGG pulsed laser ({lambda} = 2,78 {mu}m). The resulting temperature was recorded 2 s prior, 10 s during irradiation and continuing for 2 more seconds after it. After each irradiation, all obtained thermal images were processed in the software, creating a file with the data of thermal diffusivity as a function of temperature. Another file with the thermal diffusivity values was also calculated after each laser pulse. The mean result of thermal diffusivity obtained for dental enamel was 0,0084 {+-} 0,001 cm2/s for the temperature interval of 220-550 degree C. The mean value for thermal diffusivity obtained for dentin was 0,0015 0,0004 cm2/s in temperatures up to 360 degree C; however, this value increases for higher temperatures. According to these results, it was possible to conclude that the use of infrared thermography, associated with the software developed in this work, is an efficient method to determine the thermal diffusivity values as a function of temperature in different materials. (author)

  11. Alternative methodology for the margin determination of voltage stability in electrical power systems. Economical and technical impacts; Metodologia alternativa para a determinacao da margem de estabilidade de tensao em sistemas eletricos de potencia - impactos tecnicos e economicos

    Energy Technology Data Exchange (ETDEWEB)

    Cortez, Anderson Neves [Companhia Energetica de Minas Gerais (CEMIG), Belo Horizonte, MG (Brazil)]. E-mail: anderson@cemig.com.br

    2001-07-01

    This article presents an alternative methodology of voltage stability determination of Electrical Power System (EPS), focusing technical and economical aspects. In this direction, it presents relative aspects to mathematical modelling to analyse the phenomenon and also the influence from the most important dynamics to be taken into consideration. It is inquired the participation of generators in the rearrangement of the adopted active power in the current criteria of margin determination. A real system is analyzed, under this aspect, indicating significant variations in the calculated values for the margins, resulting in improper investments of significant values. The proposed methodology by this article seeks to contribute to minimize such mistakes, this is done by means of focusing the long duration dynamics of generators, what constitutes an important progress in relation to the researches about them.

  12. Development of an in vitro bioassay technique for the determination of {sup 65}Zn in biological samples; Desenvolvimento da tecnica de bioanalise in vitro para determinacao de 65Zn em amostras biologicas

    Energy Technology Data Exchange (ETDEWEB)

    Audino, W.F.; Souza, W.O.; Dantas, A.L.; Dantas, B.M., E-mail: warner@ird.gov.br, E-mail: bmdantas@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Centro de Dosimetria. Lab. de Monitoracao In Vivo

    2012-07-01

    The maintenance of the cyclotron in operation at the IEN-CNEN, where {sup 123}I is produced, may lead to the incorporation of {sup 65}Zn, generated by activation of the copper present in the shield, and the consequent internal exposure of the workers. The IRD Whole Body Counter carried out about 500 in vivo measurements, through the detection 1115 keV photons. The {sup 123}I production plant at the IEN is safe in terms of radioprotection, since all positive results represent a fraction of the annual dose limit established by the CNEN. However, in order to improve internal monitoring of the group of workers, a gamma spectrometry technique was developed at the IRD Bioassay Laboratory, aimed to the determination of {sup 65}Zn in biological samples. The calibration of the HPGe detection system was accomplished with a {sup 65}Zn liquid standard source produced and certified by the LNMRI-IRD. The source was divided into two bottles of 1 and 2 liters. A calibration curve of efficiency vs volume was obtained for each geometry in the range of 100 to 1000 mL and 1000 to 2000 mL, respectively, increasing the volume in 100 mL steps with a 0.1 M solution of HCl. The methodology has shown to be simple, fast, and presented adequate sensitivity for its application in occupational monitoring. The minimum detectable activity of the technique at 1 L is 5,18 Bq, which represents a Minimum Detectable Effective Dose of 23 {mu}Sv, assuming a single incorporation of {sup 65}Zn by ingestion of a compound Type S. (author)

  13. Determination of Pu-238 and Pu-239+240 in marine sediment samples of southern brazilian coast; Determinacao de Pu-238 e Pu-239+240 em amostras de sedimento marinho da costa sul brasileira

    Energy Technology Data Exchange (ETDEWEB)

    Figueira, Rubens C.L.; Cunha, Ieda Irma Lamas [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil)]. E-mail: figueira@curiango.ipen.br; Furtado, Valdenir V.; Tessler, Moyses G. [Sao Paulo Univ., SP (Brazil). Inst. Oceanografico

    2000-07-01

    This work presents Pu-238 and Pu-239+240 levels from southern brazilian coast, in the region between Cabo de Santa Marta Grande (SC) and Cabo Frio (RJ), involving the seaside to external continental shelf. Pu-238 and Pu-239+240 levels in this region ranged from 15 to 150 mBq.kg{sup -1} and from 18.2 to 228 mBq.kg{sup -1}, respectively. The values are in agreement with the established range for south hemisphere as a result of the atmospheric fallout. The methodology for plutonium determination reached 30% to 75% as yield recovery and 4.2 mBq.kg{sup -1} as minimum detectable concentration (MDC). Thus the methodology is applicable to environmental samples analysis at low levels of the studied radionuclides. (author)

  14. Impregnation of 12-tungstophosphoric acid on silica - part I: determination of impregnation parameters, characterization and evaluation of catalytic activity; Impregnacao do acido 12-fosfotungstico em silica - parte I: determinacao de parametros de impregnacao, caracterizacao e avaliacao da atividade catalitica

    Energy Technology Data Exchange (ETDEWEB)

    Scroccaro, Karine Isabel; Tanobe, Valcineide Oliveira de Andrade; Cocco, Lilian Cristina; Yamamoto, Carlos Itsuo, E-mail: karineisabel@yahoo.com.br [Universidade Federal do Parana, Curitiba, PR (Brazil). Centro Politecnico. Dept. de Engenharia Quimica; Wypych, Fernando [Universidade Federal do Parana, Curitiba, PR (Brazil). Centro Politecnico. Dept. de Quimica

    2012-07-01

    Catalyst based on Kegging-type heteropolyacids (H{sub 3}PW{sub 12}O{sub 40} - HPA), supported on SiO{sub 2} (H{sub 3}PW), were prepared by the impregnation method under different thermal treatment conditions. The materials were characterized by different instrumental techniques and used as catalysts in the methyl esterification reactions of stearic acid. Using the catalyst with 15% of HPA, conversions higher than 60% were obtained after 2 h of reaction at 65 deg C. Recovery studies using hot-filtration with ethanol at 75 deg C showed satisfactory activity for two additional reaction cycles. (author)

  15. Uranium determination in sea water using the isotopic dilution technique and HR-ICPMS; Determinacao de uranio em agua do mar por meio da tecnica de diluicao isotopica e HR-ICPMS

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, Marcio Henrique da Costa; Sarkis, Jorge Eduardo de Souza; Hortellani, Marcos Antonio, E-mail: mhcper@yahoo.com.b, E-mail: jesarkis@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Nascimento, Marcos R.L. [Laboratorio de Pocos de Caldas (LAPOC/CNEN-MG), MG (Brazil)

    2009-07-01

    In this work, the uranium total and the isotopic composition in seawater were calculated using the isotopic dilution applied to the mass spectrometry. The used tracer was a {sup 233}U solution . Near 99 % of the present salts in the matrix were separated by evaporation up to the saturation point. The uranium present in aqueous phase was separated from the matrix through the ion exchange chromatography using the strong Dowex 1 x 8 200-400 mesh anionic resin in chloridric medium 12 M. The analyses were performed in a high resolution mass spectrometer with plasma inductively coupled source. The method validation was done using the seawater standard CASS-4 (Near shore Seawater Reference Material for Trace metals) produced by the NRC C. The procedure allowed to obtain the fractions exempt of salts, having as consequence a greater stability in the analytical signal, and a rise in the instrumental revenue for a great number of samples. The uranium found in the samples was present in levels considered naturals and were obtained with a precision near 2 %

  16. The use of neutron diffraction for the determination of the in-depth residual stresses profile in weld coatings; A utilizacao da difracao de neutroes na determinacao do perfil de tensoes residuais em revestimentos por soldadura

    Energy Technology Data Exchange (ETDEWEB)

    Marques, Maria Jose; Batista, A.C.; Nobre, J.P. [Universidade de Coimbra (Portugal). Dept. de Fisica. Centro de Estudos de Materiais por Difraccao de Raios X (CEMDRX); Loureiro, Altino [Universidade de Coimbra (Portugal). Dept. de Engenharia Mecanica. Centro de Engenharia Mecanica (CEMUC); Kornmeier, Joana R., E-mail: mjvaz@fe.up.pt [Technische Universitaet Muenchen, Garching (Germany). FRM II

    2013-04-15

    The neutron diffraction is a non-destructive technique, particularly suitable for the analysis of residual stress fields in welds. The technique is used in this article to study ferritic samples, coated by submerged arc welding using stainless steel filler metals. This procedure is often used for manufacturing process equipment for chemical and nuclear industries, for ease of implementation and economic reasons. The main disadvantage of that processes is the cracking phenomenon that often occurs at the interface between the base material and coatings, which can be minimized by performing post-weld stress relief heat treatments. The samples analyzed in this study were made of carbon steel plates, coated by submerged arc welding two types of stainless steel filler metals. For the first layer was used one EN 12 072 - S 2 U 23 12 electrode, while for the second and third layers were used an EN 12 072 - 19 12 3 S L electrode. After cladding, the samples were submitted to a post-weld heat treatment for 1 hour at 620 deg C. The residual stress profiles obtained by neutron diffraction evidence the relaxation of residual stress given by the heat treatment. (author)

  17. Analysis of the effects of the optimal shut-in point of injector wells on water management strategy; Analise do efeito da determinacao do ponto de fechamento dos pocos injetores na estrategia de gerenciamenro de agua

    Energy Technology Data Exchange (ETDEWEB)

    Mazo, Eduin Orlando Munoz; Barreto, Carlos Eduardo Andrade Gomes; Schiozer, Denis Jose [Centro de Estudos de Petroleo (CEPETRO/UNICAMP), SP (Brazil); Teixeira, Lucas Breda [Universidade Estadual de Campinas (DEP/FEM/UNICAMP), SP (Brazil). Fac. de Engenharia Mecanica. Dept. de Engenharia de Petroleo

    2012-07-01

    The use of water cut as a parameter for determining the shut-in point of production wells is very frequent. However, in most cases, the value of this parameter that is used in the process is not optimized, which can lead to suboptimal performance, as shown in this work. An additional way to improve the water management strategy of the field is set by controlling the injection rate by determining the optimal shut-in point of an injection well, which should be closed when its interaction with the producing wells is negative for their financial performance. To know the interaction between the injector and the producer wells becomes important in order to determine the most appropriate time for the closure of the injector wells. The objective of this study is to illustrate a methodology that allows the optimization of the development and water management strategy of oil fields by using the shut-in control of injection wells, in addition to managing production wells, using numerical reservoir simulation. For this study three case studies are proposed: (1) simulation of a homogeneous and isotropic reservoir model, with the purpose of determining the injection shut-in point by the water cut value obtained from the economic scenario, (2) simulation of the process in simplified cases of heterogeneous reservoirs and (3) application of the methodology to a case of more complex reservoir geology and well configuration in different economic scenarios. The results show that for reservoirs with expected production of large volumes of water and flow high injection rates, the isolated use of water cut for producing wells control as the only procedure to manage the flow of water within the reservoir may be insufficient. Moreover, depending on the price scenario used in economic forecasting and considering cases with heterogeneities, the determination of the shut-in point of injection and producing wells individually can be the most appropriate option for the development and water management strategy of the field. (author)

  18. Neutron activation analysis application for determining iron concentration in forage grasses used in intensive cattle production system; Aplicacao da analise por ativacao com neutrons para determinacao de ferro em forrageiras usadas no sistema intensivo de producao de bovinos de leite

    Energy Technology Data Exchange (ETDEWEB)

    Armelin, Maria Jose A. [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil); Primavesi, Odo [Empresa Brasileira de Pesquisa Agropecuaria, Sao Carlos, SP (Brazil). Centro de Pesquisa de Pecuaria do Sudeste

    2002-07-01

    Iron is an essential element to the life. It is an important hemoglobin component and it is involved in the transport of oxygen to cells. A deficiency of iron results in an unsuitable synthesis of hemoglobin and a delay in the growth. Iron contents above the tolerable level in animal feed can cause serious damages to the health and the death in extreme cases. The forages are the main source of feed to cattle in grazing. It is known from the literature, that the growth and the nutritious value of the forage are influenced by specie and physiologic age of the plant, soil fertility and environmental conditions. Therefore, an agronomical evaluations of the forages are necessary before to introduce in an intensive cattle production systems to program adequate grazing management. Neutron activation analysis was applied to evaluate the Fe concentration in the main tropical forage grasses used in intensive dairy cattle production systems in Sao Carlos, SP, Brazil. Iron concentrations were smaller in the rain season than in the dry one. Comparison of results obtained in the analyses of forages with daily requirements of iron in dry matter, showed that the Fe concentration in forages was adequate. (author)

  19. Formulation of models for determination of the fuel gas demand and consumption in residential buildings; Formulacao de modelos para determinacao da demanda e consumo de gas combustivel em edificios residenciais

    Energy Technology Data Exchange (ETDEWEB)

    Ilha, Marina Sangoi de Oliveira [Universidade Estadual de Campinas, SP (Brazil). Faculdade de Engenharia Civil. Dept. de Hidraulica e Saneamento; Goncalves, Orestes Marracini [Sao Paulo Univ., SP (Brazil). Escola Politecnica. Dept. de Engenharia de Construcao Civil

    1996-07-01

    This work presents models for design flow rate and gas volume determination in residential buildings. First, an experimental investigation, applied on a sample of residential buildings at Sao Paulo, Brazil, is described, which essentially consisted in the filling of a form and measurement of gas volume at one minute interval during 10 days (mean). From this data, it was performed a regression analysis in order to explain design flow rate (demand) and gas volume values (consumption), based on different variables. Models proposed on this work are different from the current applied methodology due to their 'open' approach, that is, involved variables can be explicitly found in formulas. (author)

  20. In vivo determination of the {sup 99m}Tc-MDP incorporated activity in bone tissue; Determinacao in vivo da atividade incorporada de {sup 99m} Tc-MDP no tecido osseo

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Joseane Fonseca; Braga, Francisco J.H.N. [Sao Paulo Univ., Ribeirao Preto, SP (Brazil). Faculdade de Filosofia, Ciencias e Letras. Dept. de Fisica e Matematica; Dantas, Bernardo M.; Bertelli, Luiz [Instituto de Radioprotecao e Dosimetria (IRD), Rio de Janeiro, RJ (Brazil); Ghilardi Netto, Thomaz [Sao Paulo Univ., Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Centro de Ciencias da Imagem e Fisica Medica

    1998-07-01

    For determining in vivo {sup 99m}Tc-MDP incorporated activity in bone tissue using a scintillation chamber as a image detection and acquisition system it is necessary the system calibration using an anthropomorphic physical simulator. The development of a tibia and fibula simulator in order to estimate bone tissue activity is presented. This procedure can be used either for workers monitoring or for the metabolic behavior of this radiopharmaceutical.

  1. Procedure for determination of the decontamination of piping in the production of iodine-125 seeds; Procedimento para determinacao da descontaminacao de tubulacoes, na producao de sementes de iodo-125

    Energy Technology Data Exchange (ETDEWEB)

    Moura, J.A.; Moura, E.S.; Sprenger, F.E.; Nagatomi, H.R.; Zeituni, C.A.; Feher, A.; Manzoli, J.E.; Souza, C.D.; Rostelato, M.E.C.M., E-mail: elisaros@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2009-07-01

    Iodine-125 seeds are radioactive sources used in the prostate cancer treatment. This work objective was to determine the necessary conditions and procedures for decontamination of liquid transfer tubes when a radioactive material leakage occurs during the process of seed quality control

  2. Study of calibration equations of {sup 137}Cs methodology for soil erosion determination; Estudo de equacoes de calibracao para metodologia do {sup 137}Cs de determinacao da erosao de solos

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Elias Antunes dos

    2001-02-01

    Using the method of {sup 137} Cs and gamma-ray spectrometry, soil samples of two plots erosion were studied at Londrina city. the soil class studied was a dystrophic dark red soil (LRd), with erosion indexes measured by Agronomic Institute of Parana State (IAPAR) using a conventional method, since 1976. Through the percentage reduction of {sup 137} Cs related to the reference site, the soil losses were calculated using the proportional, mass balance and profile distribution models. Making the correlation between the {sup 137} Cs concentrations and the erosion measured by IAPAR, two calibration equations were obtained and applied to the data set measured in the basin of the Unda river and compared to those models in the literature. As reference region, was chosen a natural forest located close to the plots. The average inventory of {sup 137} Cs was 555{+-} 16 Bq.m{sup -2}. The inventories of the erosion plots varied from 112 to 136 Bq.m{sup -2} for samples collected until 30 cm depth. The erosion rates estimated by the models varied from 64 to 85 ton.ha{sup -1}.yr{sup -1} for the proportional and profile distribution models, respectively, and 137 to 165 ton.ha{sup -1} for the mass balance model, while the measured erosion obtained by IAPAR was 86 ton.ha{sup -1}.yr{sup -1}. From the two calibration equations obtained, the one that take into account the {sup 137} Cs distribution with the soil profile was that showed the best consistence with the erosion rated for the basin of the Unda river (same soil class) in the range from 4 to 48 ton.ha{sup -1}.yr{sup -1}, while the proportional and profile distribution models applied rates from 7 to 45 ton.ha{sup -1}.yr{sup -1} and 6 to 69 ton.ha{sup -1}.yr{sup -1}, respectively. (author)

  3. Development of a computer code for determining the thickness of shielding used in cardiac angiography techniques; Desenvolvimento de um codigo computacional para determinacao da espessura de barreiras utilizadas em tecnicas de angiografia cardiaca

    Energy Technology Data Exchange (ETDEWEB)

    Lava, Deise D.; Borges, Diogo da S.; Affonso, Renato R.W.; Moreira, Maria de L.; Guimaraes, Antonio C.F., E-mail: deise_dy@hotmail.com, E-mail: diogosb@outlook.com, E-mail: raoniwa@yahoo.com.br, E-mail: malu@ien.gov.br, E-mail: tony@ien.gov.br [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2014-07-01

    The construction of an effective shielding against the interaction of ionizing radiation in X-ray rooms requires consideration of many variables. The methodology used for specification of a primary and secondary shielding thickness of a X-ray room considers the following factors: use factor, occupational factor, distance between the source and the wall, workload, Kerma in the air and distance between the patient and the receptor. The program built from this data, has the objective of identifying and using variables in functions obtained through linear regressions of graphics offered by NCRP Report-147 (Structural Shielding Design for Medical X-Ray Imaging Facilities) for the shielding calculation of the room walls as wall dark room and adjacent areas. With the methodology constructed a program validation is done by comparison of results with a base case provided by that report. The values of the thicknesses obtained comprise various materials such as steel, wood and concrete. Once validated an application is made in a real case of X-ray room. His visual construction is done with the help of software used in modeling of interiors and exteriors. The construction of shielding calculating program has the goal of being an easy tool for planning of X-ray rooms in order to meet the established limits by CNEN-NN-3:01 published in September 2011.

  4. Multicriteria contribution approach for the determination of energy planning politics at new exploratory frontiers of hydrocarbon; Contribuicao da abordagem multicriterio para a determinacao de politicas de planejamento energetico em novas fronteiras exploratorias de hidrocarbonetos

    Energy Technology Data Exchange (ETDEWEB)

    Rocha, Fabio Guimaraes; Bulhoes, Fernando Cesar Chagas [PETROBRAS, Rio de Janeiro, RJ (Brazil)], Emails: fg.rocha@petrobras. com.br, fernando.bulhoes@petrobras.com.br

    2010-07-01

    This paper considers that, given the complexity of the involved factors (environmental, social, technological, economical and financial questions), the multi criteria approach can be viewed as important help tool in the definition of politic related to new hydrocarbon exploratory frontiers. To give subsides to this argument, it was made a bibliographical review, being highlighted the involved risks in exploitation and production activities, and the importance of taking into consideration the preferences of the individuals decision. Methodologies are presented, highlighting the different viewing of the american and french schools. A panorama of random variables involved in decision making of investments in new exploratory frontiers also is presented, emphasizing the importance their importance in the future offer petroleum and the challenges involved in that activity.

  5. Application of neutron activation analysis for the determination of essential elements in egg samples; Aplicacao da analise por ativacao com neutrons para a determinacao de elementos essenciais em amostras de ovos

    Energy Technology Data Exchange (ETDEWEB)

    Gomes, Bruna G.; Maihara, Vera A.; Avegliano, Roseane P., E-mail: brunagabrielegomes@gmail.com, E-mail: vmaihara@ipen.br, E-mail: pagliaro@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-07-01

    The eggs are among the twenty foods consumed by the population of the five major regions of Brazil. Among the types of eggs, there are differences in nutritional value, which can vary according to the food of the bird. This study evaluating the elements Cl, K, Mg, Mn and Na considered essential micronutrients in food, because they are fundamental in several metabolic processes necessary for the maintenance and training of the human body. We analyzed three types of eggs: egg whites, of the quail, and the colonial in cooked and raw form, using the Instrumental Neutron Activation Analysis method (INAA). The egg samples were lyophilized and pulverized before analysis. To validate the methodology, reference materials NIST RM 8415 Whole Egg Powder and NIST SRM 1567 Wheat Flour were analyzed. The samples, reference materials and standards of the elements were irradiated for 20 seconds under a thermal neutron flux of 6,6x10{sup 12} cm -2 s -1 in the nuclear research reactor IEA-R1 of IPEN-CNEN / SP. The results were consistent with the values of the Brazilian Table of Food Composition (TACO)

  6. Determination of natural radioactivity of groundwater and surface of Brumadinho and Nova Lima, Brazil; Determinacao da radioatividade natural de agua subterranea e superficial de Brumadinho e Nova Lima, Brasil

    Energy Technology Data Exchange (ETDEWEB)

    Faria, Ligia Santana de

    2013-07-01

    The municipalities of Brumadinho and Nova Lima are located in the metropolitan area of Belo Horizonte city. They are of ecological interest since they belong to an Environmental Protection Area, which is located on a very important deposit of iron ore. In addition of mineral wealth, the region has a geological characteristic that includes quartzitic conglomerates associated with uranium and significant potential underground water with hydrogeological characteristics very particular and complex, as the Quartzite Aquifer, which belongs to a geological formation called the 'Moeda Formation'. In the present work radiometric measurements were performed for 44 water samples. The samples were collected in four geographical points, three of them situated in Brumadinho (surface water) and one point situated in Nova Lima municipality (underground water). The period of sampling extended for a thirteen months period. Some of these locations was used as an alternative sampling point. Uranium and thorium concentrations of the samples were determined using an Inductively Coupled Plasma Mass Spectrometer. The content of gross alpha and gross beta activity, and the concentration of the radionuclides {sup 226}Ra, {sup 228}Ra e {sup 210}Pb were determinate by using Spectrometer Liquid Scintillation. In this case was necessary to calibrate the spectrometer using {sup 241}Am e {sup 90}Sr/{sup 90}Y standards. The resultants values were compared with those recommended by the World Health Organization, Ministry of Health and the National Council of the Environment. The maximum level of water natural radioactivity found was 0,275 ± 0,052 Bq.L{sup -1} for gross alpha radiation, 0,130 ± 0,046 Bq.L{sup -1} for {sup 226}Ra and 0,096 ± 0,005 Bq.L-1 for {sup 228}Ra. The levels of gross beta activity and {sup 210}Pb were below the detection limit. The maximum concentrations of uranium and thorium found were 0,068 μg.L{sup -1} and 0.027 μg.L{sup -1} respectively. (author)

  7. Determination of loss of tension in old green line that joining the furnaces VM1 e Panela1; Determinacao da queda de tensao na antiga linha verde de alimentaco dos fornos VM1 e Panela1

    Energy Technology Data Exchange (ETDEWEB)

    Panunzio, Paulo Armando; Magalhaes Sobrinho, Pedro [UNESP, Guaratingueta, SP (Brazil); Manfrin, Antonio Carlos [Villares Metals S.A., SP(Brazil). Unidade Sumare

    2009-11-01

    The objective of this work is to demonstrate the gains obtained with electrical energy, due to replacement of electric cables of air called 'power of the green line to arc furnaces VM1 and panel 1 of Villares Metals - Unit Sumare' by underground cables. We can mention other gains in safety, maintenance, environment and quality of power, but will not be measured. This substitution was motivated due to the existing line to the limit of its useful life, with restrictions to increase the load (expansion) and stops unwanted maintenance. It is emphasized that this determination is the only power loss due to ohmic resistance of bare aluminum conductor used in the old line (green). The economy demonstrated in this study is R$ 3,313.21 and 16.339752 MWh even if it is significantly reduced because there is a spare in MWh, which can be used within the company in which extensions are necessary. (author)

  8. Determination of gamma radiation dose to the destruction of Escherichia coli O157: H7 in hamburger;Determinacao da dose de radiacao gama para a destruicao de Escherichia coli O157:H7 em hamburguer bovino

    Energy Technology Data Exchange (ETDEWEB)

    Orejuela Chirinos, Rodolfo Raul

    1999-07-01

    Escherichia coli O157:H7 has been incriminated in several foodborne outbreaks due to the consumption of different kinds of foods. Among these, hamburgers are the most common. Irradiation process is an effective method for food preservation because it causes no significant change in organoleptic and nutritional food characteristics and destroys pathogens and spoilage microorganisms. Hamburgers and nutrient broth inoculated with Escherichia coli O157:H7 were submitted to gamma irradiation ({sup 60}Co) treatment, with doses ranging from 0,0 to 0,7 kGy in order to calculate the D{sub 10} for this bacteria in these substrate. The D{sub 10} for the pathogen nutrient broth ranged from 0.08 kGy to 0.10 kGy and in hamburger from 0.11 kGy to 0.21 kGy. Considering the highest D{sub 10} value in hamburger, a dose of 0,8 kGy would not change the sensorial characteristics of the product, and would reduce the population of E. coli O157:H7 in 4 cycles logarithmic. (author)

  9. Determination of trace elements in Mesozoic dykes of the Serra do Mar by neutron activation; Determinacao de elementos tracos em diques mesozoicos da Serra do Mar por meio de ativacao com neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Vicentini, Caio M.; Marques, Leila S., E-mail: caio.vicentini@usp.br, E-mail: leila@iag.usp.br [Universidade de Sao Paulo (IAG/USP), Sao Paulo, SP (Brazil). Instituto de Astronomia, Geofisica e Ciencias Atmosfericas; Figueiredo, Ana Maria G., E-mail: anamaria@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-07-01

    The analysis of trace elements such as rare earths, Th, U, Ta, Hf, Ba, Rb and Ba, is a very important tool for petrogenetic studies. In order to study these processes in dykes of Enxame Serra do Mar (Coast of Sao Paulo and Rio de Janeiro), belonging to the Parana Magmatic Province (PMP), one of the most significant provinces of continental basalts in the world, were perform analyzes by neutron activation in these dikes. The technique, employed in Centro de Reator de Pesquisa of the Instituto de Pesquisas Energeticas e Nucleares, provided concentrations of trace elements with accuracy levels of 10% and 9%, which are suitable for petrogenetic studies. Due to the low concentrations of the elements analyzed, the experimental routine sample preparation processes covered very careful to avoid contamination. The samples investigated can be divided into four groups: basic rocks (SiO{sub 2} <55%) with Ti / Y> 500; basic rocks with Ti / Y <500; intermediate rocks (55% 63%). Dikes of intermediate and acid composition only occur at the Sao Sebastiao Island and adjacent coastal region. The concentrations of major and minor elements, as well as the abundance patterns of rare earths and other incompatible elements of these more differentiated rocks, show significant similarities with the type of the volcanic Chapeco, suggesting similar genesis, in other worlds, including also processes of crustal contamination.

  10. Study of the precision and trueness of the Brazilian method for ethanol and gasoline determination; Estudo da precisao e exatidao do metodo brasileiro para determinacao de etanol e gasolina

    Energy Technology Data Exchange (ETDEWEB)

    Zucchini, Ricardo R.; Hinata, Patricia [Instituto de Pesquisas Tecnologicas (IPT), Sao Paulo, SP (Brazil); Gioseffi, Carla S.; Franco, Joao B.S. [Instituto Brasileiro de Petroleo, Gas e Biocombustiveis (IBP), Rio de Janeiro, RJ (Brazil); Nascimento, Cristina R.; Torres, Eduardo S. [Agencia Nacional do Petroleo, Gas Natural e Biocombustiveis (ANP), Rio de Janeiro, RJ (Brazil)

    2008-07-01

    The determination of repeatability and reproducibility standard deviations of an analytical method, s{sub r} and s{sub R}, obtained by Interlaboratory program, makes it possible to calculate many kinds of precision limits of the method, which are needed in every laboratory's routine result comparisons and also in between-laboratories comparisons. This paper presents the results of the first interlaboratory trial, accomplished in the Brazilian petroleum sector, performed to define the trueness and precision of the Brazilian standard method for the determination of fuel anhydrous ethylic alcohol content in gasoline, that was performed by 34 experienced laboratories. The r and R values were 0,7 and 2,3 and main factors that would improve and optimize the method are presented. (author)

  11. Determination of the survival curve of the cell irradiated with low dose rate neutrons; Determinacao da curva de sobrevivencia de celulas irradiadas com neutrons a baixa taxa de dose

    Energy Technology Data Exchange (ETDEWEB)

    Mendes, Bruno M.; Freitas, Marcelo H.A. de; Campos, Tarcisio P.R. [Minas Gerais Univ., Belo Horizonte, MG (Brazil). Dept. de Engenharia Nuclear; Silva, Luciana M.; Dias, Consuelo L.F. [Fundacao Ezequiel Dias, Belo Horizonte, MG (Brazil). Dept. de Pesquisa. Lab. de Bioquimica

    2000-07-01

    The effect of the radiation in tissue and cells are a theme of extreme importance and that is receiving large attention more and more now. This work purposes to evaluate the deleterious effects of the neutrons radiation at low dose rate in lineages of human cancerous cells through the analysis of survival curves. Deleterious effects due to radiation of low dose rate (3.8 mSv/hr) were observed in cells of the lineage HeLa S3. Previous studies, in lineage HN5 of tongue carcinoma, showed survive level to 0.2Sv of 80%, compatible to the value of 88,57% 0.4 Sv obtained for HeLa S3. In a close future, with the molecular biology characterization of a great number or possibly all cancer types (that will be accelerated largely with the conclusion of the human genome project), studies like this, can be much more specific, and could determine the efficiency of the neutrons or any other radiation type for each one of those types. Those data would have of great value for the medicine and they would help to plan the treatments better. (author)

  12. Determination of the {delta}{sup 13}C (per mille) isotopic rate of the Brazilian beer pilsen type; Determinacao da razao isotopica {delta}{sup 13}C (per mille) de cerveja clara tipo pilsen nacional

    Energy Technology Data Exchange (ETDEWEB)

    Rossete, Alexssandra L.R.M.; Bendassolli, Jose Albertino [Centro de Energia Nuclear na Agricultura (CENA), Piracicaba, SP (Brazil). Lab. de Isotopos Estaveis; Lopes, Fabio [Centro de Energia Nuclear na Agricultura (CENA), Piracicaba, SP (Brazil). Lab. de Ecologia Isotopica; Martinelli, Luiz Antonio [Universidade Estadual de Londrina, PR (Brazil). Dept. de Fisica. Lab. de Fisica Nuclear Aplicada

    2002-07-01

    Beer has been consumed in Brazil since the XIX century. However, at that time, this beverage was imported from England, and the first Brazilian breweries just appeared at the end of the XX century. Basically, beer is made from: malt of barley, Humulus lupulus, water and yeast. In this work, twenty brands of national beer (Pilsen type), and also two different cereals, barley, a C3 metabolism plant, corn, a C4 plant, were analysed to determine their isotope composition {delta}{sup 13} C (per mille) utilizing a mass spectrometer Delta Plus Finigam and Anca S.L. An aliquot of each sample was transferred using a capillary of glass to a tin capsule contends a small amount of sorbitol. The isotope compositions, {delta}{sup 13} C, of barley and corn samples determined were -27.2 and -11.5 per mille, respectively. These results were used to calculate the equation of mixture model. Considering the beer samples, the {delta}{sup 13} C ranged from -18.3 to -23.1 per mille; this result means that the percentage of C3 plant is from 43.3 to 73.9 per mille. In this manner, it is possible to concluded that all beer samples has malted cereals (C4 plant), as far as the low values of C3 plants were presented in these samples as shown through the equation of mixtures model. (author)

  13. Determination of Cl, K, and Na in the blood serum of healthy elderly in the city of Sao Paulo, SP; Determinacao de Cl, K e Na em soro sanguineo de idosos saudaveis da cidade de Sao Paulo

    Energy Technology Data Exchange (ETDEWEB)

    Araujo, Nathalia Souza de; Saiki, Mitiko, E-mail: natsouzaraujo@yahoo.com.b, E-mail: mitiko@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2009-07-01

    This work determined the blood serum concentration of Cl, K, and Na from a healthy elderly population of the city of Sao Paulo, Sao Paulo, Brazil viewing the comparison with reference values used in clinical laboratories. For collecting these samples the present work were approved by the Ethic Committee of the FMUSP and IPEN-CNEN/SP. The quality of the analytical results were evaluated by the analysis of the reference material certification NIST 1577b Bovine Liver. The results presented good accuracy and precision due to the fact that they presented relative errors less than 5.2 % and standard deviation less than 8.6 %. The average concentrations (mmol L{sup -1}) of Cl in the analysed serum were 99.1; the K were 3.9 and the Na were 136.9. The obtained data allows the to conclude that the mostly of the elderly presented Cl, K and Na concentrations in the range of reference values used in the clinical laboratories

  14. Biological effects in lymphocytes irradiated with {sup 99m}Tc: determination of the curve dose-response; Efeitos biologicos em linfocitos irradiados com {sup 99m}Tc: determinacao da curva dose-resposta

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Romero Marcilio Barros Matias de

    2002-08-01

    Biological dosimetry estimates the absorbed dose taking into account changes in biological parameters. The most used biological indicator of an exposition to ionizing radiation is the quantification of chromosomal aberrations of lymphocytes from irradiated individuals. The curves of dose versus induced biological effects, obtained through bionalyses, are used in used in retrospective evaluations of the dose, mainly in the case of accidents. In this research, a simple model for electrons and photons transports was idealized to simulate the irradiation of lymphocytes with {sup 99m} Tc, representing a system used for irradiation of blood cells. The objective of the work was to establish a curve of dose versus frequencies of chromosomal aberrations in lymphocytes of human blood. For the irradiation of blood samples micro spheres of human serum of albumin (HSAM) market with {sup 99m} Tc were used, allowing the irradiation of blood with different administered activities of {sup 99m} Tc, making possible the study the cytogenetical effects as a function of such activities. The conditions of irradiation in vivo using HSAM spheres marked with {sup 99m} Tc were simulated with MCNP 4C (Monte Carlo N-Particle) code to obtain the dose-response curve. Soft tissue composition was employed to simulate blood tissue and the analyses of the curve of dose versus biological effect showed a linear quadratic response of the unstable chromosomal aberrations. As a result, the response of dose versus chromosomal aberrations of blood irradiation with {sup 99m} Tc was best fitted by the curve Y=(8,99 {+-}2,06) x 1-{sup -4} + (1,24 {+-}0,62) x 10{sup -2} D + (5,67 {+-} 0,64) x 10{sup -2} D{sup 2}. (author)

  15. Determination of radiochemistry purity and pH of radiopharmaceutical in Northeast nuclear medicine services; Determinacao da pureza radioquimica e pH de radiofarmacos em servicos de medicina nuclear do Nordeste

    Energy Technology Data Exchange (ETDEWEB)

    Andrade, Wellington; Santos, Poliane, E-mail: wellington.gandrade@gmail.com, E-mail: polianeangelo@gmail.com [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil); Lima, Fernando de Andrade; Lima, Fabiana Farias de, E-mail: falima@cnen.gov.br, E-mail: ffmima@cnen.gov.br [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil)

    2013-07-01

    The radiopharmaceutical is a chemical compound associated with a radionuclide, which is selected so that meets the need cf diagnosis and capable of producing quality images. Drugs labeled with {sup 99m}Tc radionuclide kits consist of lyophilized, and be handled by the nuclear medicine services (NMS) must pass tests as the resolution of ANVISA (RDC 38) published in 2008. Among these tests are those of radiochemical purity and pH determination. This study evaluated the radiochemical purity of radiopharmaceuticals and pH SMN manipulated in the Northeast. The radiochemical purity (RCP) was determined by thin layer chromatography, which were used Whatman Registered-Sign and silica gel, with dimensions of 1 x 10 cm, as stationary phase, and solvents indicated in the inserts of manufacturers. The chromatographic strips were placed in sealed containers so as not to touch the walls thereof. After the chromatographic run, the tape was cut every centimeter and the activities determined in doses of each calibrator NMS. The pH of the radiopharmaceutical was assessed through the use of universal pH paper (Merck Registered-Sign ) and obtained staining compared with its color scale. The results showed (hat 82.6% and 100% of the radiopharmaceuticals of the samples were within the limits recommended by international pharmacopoeias for radiochemical purity and pl-l, respectively. There is then the need to include in routine tests indicated SMN by ANVISA. Well, they can detect possible problems in the marking of radiopharmaceuticals administered to the patient and avoid inappropriate material. (author)

  16. Determination of air kerma standard of high dose rate {sup 192}Ir brachytherapy source; Determinacao da taxa de kerma no ar de referencia para {sup 192}Ir de alta taxa de dose para braquiterapia

    Energy Technology Data Exchange (ETDEWEB)

    Pires, E.J.; Alves, C.F.E.; Leite, S.P.; Magalhaes, L.A.G.; David, M.G.; Almeida, C.E. de, E-mail: cfealves@gmail.com [Universidade do Estado do Rio de Janeiro (UERJ), Rio de Janeiro, RJ (Brazil). Lab. de Ciencias Radiologicas; Di Prinzio, R. [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    This paper presents the methodology developed by the Laboratorio de Ciencias Radiologicas and presently in use for determining of the air kerma standard of {sup 192}Ir high dose rate sources to calibrate well-type chambers. Uncertainty analysis involving the measurements procedure are presented. (author)

  17. Application of Laplace transform for determination of albedo type boundary conditions for neutronic calculations; Aplicacao da transformada de Laplace para determinacao de condicoes de contorno tipo albedo para calculos neutronicos

    Energy Technology Data Exchange (ETDEWEB)

    Petersen, Claudio Zen

    2008-07-01

    In this dissertation we use the Laplace transform to derive expressions for nonstandard albedo boundary conditions for one and two non-multiplying regions at the ends of one dimensional domains. In practice, the fuel regions of reactor cores are surrounded by reflector regions that reduce neutron leakage. In order to exclude the reflector regions from the calculations, we introduce a reflection coefficient or albedo. We use the present albedo boundary conditions to solve numerically slab-geometry monoenergetic and multigroup diffusion equations using the conventional finite difference method. Numerical results are generated for fixed source and eigenvalue diffusion problems in slab geometry(author)

  18. Determination of the air attenuation and electronic loss for the free air concentric cylinders ionization chamber; Determinacao da atenuacao do ar e perda eletronica para a camara de ionizacao de ar livre de cilindros concentricos

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Hebert Pinto Silveira de

    2010-07-01

    Along the latest years, the LNMRI has been proceeding a continuous research work with a concentric cylinders type free air ionizing chamber (VICTOREEN, model 481), aiming to establish it as a new national standard, and, as a consequence, replace the worldwide accepted secondary standard, calibrated by PTB. Taking into account that the absolute determination of kerma in air with a free air ionizing chamber implies the acquirement of a number of correction factors. The main objective of the present work comprises the determination of the two factors, specifically, electronic loss (k{sub e}) and air attenuation (k{sub a}). The correction factors were obtained through mammography qualities reference spectrum, using Monte Carlo simulation method. The Penelope code was used in the simulation procedures. Simulations took place in two stages, the acquirement of specters related to the qualities of interest (mammography) with the x ray tube (Pantak, model HF160 e Panalytical, model XRF window), and the free-air ionization chamber. The data were compared to those related to the BIPM chamber, to electronic loss were not detected. The comparison between air attenuation factors was obtained data bellow 0.13%. (author)

  19. Pyramid beam splitter

    Science.gov (United States)

    McKeown, Mark H.; Beason, Steven C.; Fairer, George

    1992-01-01

    The apparatus of the present invention provides means for obtaining accurate, dependable, measurement of bearings and directions for geologic mapping in subterranean shafts, such as, for example, nuclear waste storage investigations. In operation, a laser beam is projected along a reference bearing. A pyramid is mounted such that the laser beam is parallel to the pyramid axis and can impinge on the apex of the pyramid thus splitting the beam several ways into several beams at right angles to each other and at right angles to the reference beam. The pyramid is also translatable and rotatable in a plane perpendicular to the reference beam.

  20. Low current beam techniques

    Energy Technology Data Exchange (ETDEWEB)

    Saint, A.; Laird, J.S.; Bardos, R.A.; Legge, G.J.F. [Melbourne Univ., Parkville, VIC (Australia). School of Physics; Nishijima, T.; Sekiguchi, H. [Electrotechnical Laboratory, Tsukuba (Japan).

    1993-12-31

    Since the development of Scanning Transmission Microscopy (STIM) imaging in 1983 many low current beam techniques have been developed for the scanning (ion) microprobe. These include STIM tomography, Ion Beam Induced Current, Ion Beam Micromachining and Microlithography and Ionoluminense. Most of these techniques utilise beam currents of 10{sup -15} A down to single ions controlled by beam switching techniques This paper will discuss some of the low beam current techniques mentioned above, and indicate, some of their recent applications at MARC. A new STIM technique will be introduced that can be used to obtain Z-contrast with STIM resolution. 4 refs., 3 figs.

  1. Ionizing radiation effect study by electron beam on acrylonitrile butadiene styrene - ABS terpolymer; Estudo do efeito da radiacao ionizante por feixe de eletrons sobre o terpolimero acrilonitrila butadieno estireno -ABS

    Energy Technology Data Exchange (ETDEWEB)

    Landi, Tania Regina Lourenco

    2003-07-01

    The great advantage in the researches involving development has as objective to increase significantly the quality of the products. The ABS (acrylonitrile, butadiene, styrene) resins are terpolymers formed by an elastomer and two thermoplastics amorphous components. The three different monomeric units from the terpolymer ABS contribute separately to the material characteristics exhibited. The molecular stiffness originating from polystyrene and the benzene ring hanging on the chain is responsible for the flexion module ABS. The acrylonitrile and the styrene incorporated butadiene exercises strong influence in the resistance to the impact because it reduces the bonding among them. The engineering use of this terpolymer became important due their mechanical properties and mainly, for the responses of this to tensions or deformations applied. The polymeric materials, when submitted to the ionizing radiation are modified by the transference of energy to these materials, introducing excitation and ionization of the molecules, generating chemical reactions that can produce permanent modifications in the polymeric physicochemical structure. The induced modifications can result in the polymeric material degradation or crosslinking, which can result in the improvement of some properties. This work has, as objective, to study the electron beam ionizing radiation effect, at different doses, in the properties of the polymer ABS. The studied properties were: tensile strength at break, elongation at break, Izod impact strength, flexural strength, melt flow index, Vicat softening temperature and the thermic distortion temperature. Also researches on Differential Scanning Calorimetry (DSC) and Thermogravimetric Analyses (TGA) were accomplished. From the experimental results, it was showed that for doses until 500 kGy, at 22.6 kGy/s dose rate, in the presence of air, the crosslinking process of ABS prevails. (author)

  2. Study of the electron beam irradiation effect on some properties of aromatic aliphatic copolyester films; Estudo do efeito da radiacao por feixe de eletrons nas propriedades de filmes de copoliester alifatico aromatico

    Energy Technology Data Exchange (ETDEWEB)

    Poveda, Patricia Negrini Siqueira

    2008-07-01

    Biodegradable and green plastics are the new tendency in the world. The effect of the electron beam irradiation in aromatic aliphatic copolyester and the blend with corn starch films (Ecoflex{sup R} and Ecobras{sup R}) were studied by tensile strength at break, elongation at break, Scanning Electronic Microscopy (SEM), Fourier Transform Infrared Spectroscopy (FT-IR), Differential Scanning Calorimetry (DSC), crosslinking degree and biodegradability. The measurements in both, the machine direction and the transverse direction were made for mechanical tests. It was found that, the electron irradiation caused an increase in the strength at break of the blend with corn starch film, when doses of up to 10 kGy were applied. A significant decrease of the elongation at break of the blend with corn starch was observed at doses of 10 kGy and 40 kGy. It was not found important change in tensile properties for aromatic aliphatic copolyester. Structural changes of the samples (crosslinking or degradation) by SEM were not observed. The FT-IR identified the characteristic peaks of each involved functional group (copolyester and corn starch). However, it was not found bands of oxidation of the samples. In the DSC, changes in the melting temperature of the irradiated Ecoflex{sup R} and Ecobras{sup R} samples, was not identified when compared with the samples of reference. However, it was verified a reduction in the melting enthalpy of the Ecobras{sup R} samples after irradiation. The Ecobras{sup R} material presented crosslinking, when submitted to doses of 10 kGy and 40 kGy. The Ecoflex{sup R} material did not present crosslinking when submitted to these doses. The biodegradability of the materials was evaluated by two methods of test: soil simulated and enzymatic. In both methods, the irradiated samples presented faster biodegradation than the references not irradiated. (author)

  3. Beam-Beam Experience at KEKB

    Energy Technology Data Exchange (ETDEWEB)

    Bane, Karl LF

    2002-11-11

    KEKB has achieved the peak luminosity of 4.1 x 10{sup 33} cm{sup -2} sec{sup -1} and the present capability for delivering integrated luminosity is 224 pb{sup -1}/day. This paper describes (1) the recent performance and the problems of KEKB and (2) the comparison of beam-beam simulations with experiments at KEKB.

  4. T10 Beam Studies & Beam Simulation

    CERN Document Server

    Bergmann, Michael Georges; Van Dijk, Maarten; CERN. Geneva. EN Department

    2017-01-01

    In order to test detector components before their installation in actual experiments, one uses test beams in which one can control particle typ, momentum and size to high degree. For this project the focus of a secondary beam at T10 in the East Area at CERN was analysed using an AZALEA telescope from DESY.

  5. Beam-beam issues in asymmetric colliders

    Energy Technology Data Exchange (ETDEWEB)

    Furman, M.A.

    1992-07-01

    We discuss generic beam-beam issues for proposed asymmetric e{sup +}- e{sup -} colliders. We illustrate the issues by choosing, as examples, the proposals by Cornell University (CESR-B), KEK, and SLAC/LBL/LLNL (PEP-II).

  6. Beam Dynamics and Beam Losses - Circular Machines

    CERN Document Server

    Kain, V

    2016-01-01

    A basic introduction to transverse and longitudinal beam dynamics as well as the most relevant beam loss mechanisms in circular machines will be presented in this lecture. This lecture is intended for physicists and engineers with little or no knowledge of this subject.

  7. Successful Beam-Beam Tuneshift Compensation

    Energy Technology Data Exchange (ETDEWEB)

    Bishofberger, Kip Aaron [Univ. of California, Los Angeles, CA (United States)

    2005-01-01

    The performance of synchrotron colliders has been limited by the beam-beam limit, a maximum tuneshift that colliding bunches could sustain. Due to bunch-to-bunch tune variation and intra-bunch tune spread, larger tuneshifts produce severe emittance growth. Breaking through this constraint has been viewed as impossible for several decades. This dissertation introduces the physics of ultra-relativistic synchrotrons and low-energy electron beams, with emphasis placed on the limits of the Tevatron and the needs of a tuneshift-compensation device. A detailed analysis of the Tevatron Electron Lens (TEL) is given, comparing theoretical models to experimental data whenever possible. Finally, results of Tevatron operations with inclusion of the TEL are presented and analyzed. It is shown that the TEL provides a way to shatter the previously inescapable beam-beam limit.

  8. BEAM PIPE IS INSTALLED

    CERN Multimedia

    The installation of the central section of the beam pipe into the heart of the  CMS was completed by 23 April. All the beam pipe elements have been successfully vacuum-tested and the bakeout started.  

  9. Beam Loss in Linacs

    CERN Document Server

    Plum, M A

    2016-01-01

    Beam loss is a critical issue in high-intensity accelerators, and much effort is expended during both the design and operation phases to minimize the loss and to keep it to manageable levels. As new accelerators become ever more powerful, beam loss becomes even more critical. Linacs for H- ion beams, such as the one at the Oak Ridge Spallation Neutron Source, have many more loss mechanisms compared to H+ (proton) linacs, such as the one being designed for the European Spallation Neutron Source. Interesting H- beam loss mechanisms include residual gas stripping, H+ capture and acceleration, field stripping, black-body radiation and the recently discovered intra-beam stripping mechanism. Beam halo formation, and ion source or RF turn on/off transients, are examples of beam loss mechanisms that are common for both H+ and H- accelerators. Machine protection systems play an important role in limiting the beam loss.

  10. High energy beam lines

    Science.gov (United States)

    Marchetto, M.; Laxdal, R. E.

    2014-01-01

    The ISAC post accelerator comprises an RFQ, DTL and SC-linac. The high energy beam lines connect the linear accelerators as well as deliver the accelerated beams to two different experimental areas. The medium energy beam transport (MEBT) line connects the RFQ to the DTL. The high energy beam transport (HEBT) line connects the DTL to the ISAC-I experimental stations (DRAGON, TUDA-I, GPS). The DTL to superconducting beam (DSB) transport line connects the ISAC-I and ISAC-II linacs. The superconducting energy beam transport (SEBT) line connects the SC linac to the ISAC-II experimental station (TUDA-II, HERACLES, TIGRESS, EMMA and GPS). All these lines have the function of transporting and matching the beams to the downstream sections by manipulating the transverse and longitudinal phase space. They also contain diagnostic devices to measure the beam properties.

  11. Vortices in Gaussian beams

    CSIR Research Space (South Africa)

    Roux, FS

    2009-01-01

    Full Text Available . Gaussian beams with vortex dipoles CSIR National Laser Centre – p.2/30 Gaussian beam notation Gaussian beam in normalised coordinates: g(u, v, t) = exp ( −u 2 + v2 1− it ) u = xω0 v = yω0 t = zρ ρ = piω20 λ ω0 — 1/e2 beam waist radius; ρ— Rayleigh range ω ω...(z) 0 x z Rayleigh range Beam waist ρ ρ Rayleigh range CSIR National Laser Centre – p.3/30 Gaussian beam Gaussian beam in terms of amplitude and phase g(u, v, t) = exp ( −u 2 + v2 1 + t2 ) exp ( − it(u 2 + v2) 1 + t2 ) Normalised beam radius: √ 1 + t2...

  12. Determination of effective atomic number of breast tissues using scattered radiation; Determinacao do numero atomico efetivo de tecidos mamarios usando a radiacao espalhada

    Energy Technology Data Exchange (ETDEWEB)

    Antoniassi, M.; Conceicao, A.L.C.; Poletti, M.E. [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Fac. de Filosofia, Ciencias e Letras. Dept. de Fisica e Matematica

    2010-07-01

    The scattered radiation has been used in several industrial and clinical applications since it permits to characterize the scattering material. Several types of information can be extracted from the spectrum of scattered radiation which can be used to characterization of biological tissues such as breast tissues. In this work we have measured Compton and Rayleigh scattering radiation from normal (adipose), benign (fibroadenoma) and malignant (carcinoma) neoplastic breast tissues using a monoenergetic beam of 17.44 keV and a scattering angle of 90 deg C (x = 0.99 angstrom-1). A practical method using the area of elastic and inelastic scattering was used for determining the effective atomic number (Z{sub eff}) of the samples, being validated comparing the experimental obtained values of Z{sub eff} of several standard materials with calculated values using traditional method based on total cross-section of compounds. The obtained results show that exist differences in the distributions of Z{sub eff} of breast tissues, which are related to the content of carbon (Z=6) and oxygen (Z=8) in each tissue type. The results suggest that is possible to use this parameter for characterizing breast tissues, pointing the possibility of its use as a complementary tool for the diagnosis of the breast cancer. (author)

  13. Empirical model for controlling beam-beam effects in ISABELLE

    Energy Technology Data Exchange (ETDEWEB)

    Parzen, G

    1980-01-01

    The beam-beam interaction may limit the beam intensity in ISABELLE. Although considerable progress has been made in understanding the beam-beam interaction, there appears to be no reliable method at present for computing the effects of the beam-beam interaction. The steps taken at ISABELLE to limit beam-beam effects are based largely on the experience accumulated at the ISR. At the ISR, the beam-beam effects do not appear to be large, and the beam intensity at the ISR does not appear to be limited by beam-beam effects. The beam-beam effects may be much stronger in ISABELLE because of factors like higher intensity and stronger non-linearities.

  14. Electron Beam Ion Sources

    OpenAIRE

    Zschornacka, G.; Schmidt, M.; Thorn, A.

    2014-01-01

    Electron beam ion sources (EBISs) are ion sources that work based on the principle of electron impact ionization, allowing the production of very highly charged ions. The ions produced can be extracted as a DC ion beam as well as ion pulses of different time structures. In comparison to most of the other known ion sources, EBISs feature ion beams with very good beam emittances and a low energy spread. Furthermore, EBISs are excellent sources of photons (X-rays, ultraviolet, extreme ultraviole...

  15. Electron beam focusing system

    Energy Technology Data Exchange (ETDEWEB)

    Dikansky, N.; Nagaitsev, S.; Parkhomchuk, V.

    1997-09-01

    The high energy electron cooling requires a very cold electron beam. Thus, the electron beam focusing system is very important for the performance of electron cooling. A system with and without longitudinal magnetic field is presented for discussion. Interaction of electron beam with the vacuum chamber as well as with the background ions and stored antiprotons can cause the coherent electron beam instabilities. Focusing system requirements needed to suppress these instabilities are presented.

  16. Beam Dynamics for ARIA

    CERN Document Server

    Ekdahl, Carl

    2015-01-01

    Beam dynamics issues are assessed for a new linear induction electron accelerator being designed for flash radiography of large explosively driven hydrodynamic experiments. Special attention is paid to equilibrium beam transport, possible emittance growth, and beam stability. It is concluded that a radiographic quality beam will be produced possible if engineering standards and construction details are equivalent to those on the present radiography accelerators at Los Alamos.

  17. Beam Dynamics for ARIA

    Energy Technology Data Exchange (ETDEWEB)

    Ekdahl, Carl August Jr. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2014-10-14

    Beam dynamics issues are assessed for a new linear induction electron accelerator being designed for flash radiography of large explosively driven hydrodynamic experiments. Special attention is paid to equilibrium beam transport, possible emittance growth, and beam stability. It is concluded that a radiographic quality beam will be produced possible if engineering standards and construction details are equivalent to those on the present radiography accelerators at Los Alamos.

  18. Determination of the Antarctic region active margin basement by using integration of the information coming from the multichannel seismic analysis and the magnetometry; Determinacao do embasamento da margen ativa da regiao Antartica pela integracao de informacoes provenientes da sismica multicanal e da magnetometria

    Energy Technology Data Exchange (ETDEWEB)

    Torres, Luiz Carlos [Diretoria de Hidrografia e Navegacao, XX (Brazil); Gomes, Benedito Souza [PETROBRAS S.A., Rio de Janeiro, RJ (Brazil); Gamboa, Luiz Antonio P. [Universidade Federal Fluminense, Niteroi, RJ (Brazil)

    1999-07-01

    Geophysical measurements were carried out in the Western Margin of the Antarctic Peninsula and Bransfield Strait by the Brazilian Antarctic Program during the summers of 1987 and 1988. The present work, using a continued seismic multi channel and magnetometry data profile crossing the area, intends to present a two-dimensional model of the interface sediment/basement and contribute to the understanding of the complex geology verified in the studying area. By this model, the main provinces of the are (Deep Ocean, South Shetland Trench, Accretionary Prism, Volcanic Arc South Shetland Islands and Bransfield Basin) could be determined. The seismic and magnetic measurements information when superposed can attribute more consistencies to the interpreted basement; although each method has its particular resolution. This way, when the seismic interpretation was not possible due to complex structures disposition, magnetic measurements could offer good estimation about basement depth. The fit between both methods (seismic and magnetic measurements) was reasonable both on the oceanic basin and in the region of Bransfield Strait. The magnetometry, as as well seismic, was sensible to the dip of Drake Plate at South Shetland Trench and the Intrusive occurrence at Bransfield Basin axis. (author)

  19. Beam injection into RHIC

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, W.; Hahn, H.; MacKay, W.W.; Satogata, T.; Tsoupas, N.; Zhang, W.

    1997-07-01

    During the RHIC sextant test in January 1997 beam was injected into a sixth of one of the rings for the first time. The authors describe the injection zone and its bottlenecks. They report on the commissioning of the injection system, on beam based measurements of the kickers and the application program to steer the beam.

  20. An Electromagnetic Beam Converter

    DEFF Research Database (Denmark)

    2009-01-01

    The present invention relates to an electromagnetic beam converter and a method for conversion of an input beam of electromagnetic radiation having a bell shaped intensity profile a(x,y) into an output beam having a prescribed target intensity profile l(x',y') based on a further development...

  1. Halo formation from mismatched beam-beam interactions

    Energy Technology Data Exchange (ETDEWEB)

    Qiang, Ji

    2003-05-23

    In this paper, we report on the halo formation and emittance growth driven by a parametric resonance during mismatched beam-beam collisions. In the regime of the weak-strong beam-beam interaction, if two beams have the same machine tunes, on-axis head-on collisions between a mismatched strong beam and a weak beam will not cause the formation of halo. However, if the two beams collide with an initial offset, the beam-beam force from the mismatched strong beam can cause halo formation and emittance growth in the weak beam. Meanwhile, if two beams have different machine tunes, for opposite charged colliding beams, when the machine tune of the weak beam is smaller than that of strong beam, there is emittance growth in the weak beam. When the machine tune of the weak beam is larger than that of the strong beam, there is little emittance growth. In the regime of strong-strong beam-beam interaction, halo is formed in both beams even when the two beams collide head-on on the axis with equal machine tunes. This puts a strong requirement for a good beam match during the injection to colliders in order to avoid the emittance growth.

  2. ALICE Injected Beam Accidents

    CERN Document Server

    Appleby, R B

    2009-01-01

    The ALICE (point 2) interaction region is sensitive to beam orbit errors arising from magnet setting errors on injection. In this report, beam accident scenarios under injection for ALICE are described, focusing on ultra- fast error injection scenarios for the interaction straight correctors and dipoles. Beam 1 and beam 2 accident scenarios are considered, where the errors can lead to beam orbits striking the ALICE vacuum chamber or elements of the machine. The required thresholds for magnet current interlocks are calculated to avoid machine and detector risk.

  3. LHCb Injected Beam Accidents

    CERN Document Server

    Appleby, R B

    2009-01-01

    The LHCb (point 8) interaction region is sensitive to beam orbit errors arising from magnet setting errors on injection. In this report, beam accident scenarios under injection for LHCb are described, focusing on ultra- fast error injection scenarios for the interaction straight correctors and dipoles. Beam 1 and beam 2 accident scenarios are considered, where the errors can lead to beam orbits striking the LHCb vacuum chamber or elements of the machine. The required thresholds for magnet current interlocks are calculated to avoid machine and detector risk.

  4. Refractive beam shapers for focused laser beams

    Science.gov (United States)

    Laskin, Alexander; Laskin, Vadim; Ostrun, Aleksei

    2016-09-01

    Focusing of laser radiation is most often used approach in various industrial micromachining applications like scribing, PCB drilling, and is important in scientific researches like laser heating in geophysics experiments with diamond anvil cells (DAC). Control of intensity distribution in focal spot is important task since optimum intensity profiles are rather flat-top, doughnut or "inverse-Gauss" than typical for lasers Gaussian profile. Because of high intensity of modern CW and pulsed lasers it is advisable to use refractive beam shaping optics with smooth optical surfaces providing high radiation resistance. Workable optical solutions can be built on the base of diffraction theory conclusion that flat-top intensity profile in focal plane of a lens is created when input beam has Airy-disk intensity distribution. It is suggested to apply refractive beam shapers converting, with minimum wavefront deformation, Gaussian profile of TEM00 beam to a beam with Airy disk intensity distribution, thereby optimizing conditions of interference near the focal plane of a lens after the beam shaper and providing flat-top, doughnut, "inverse-Gauss" profiles. This approach allows operation with CW and ultra-short pulse lasers, using F-theta lenses and objectives, mirror scanners, provides extended depth of field similar to Rayleigh length of comparable TEM00 beam, easy integration in industrial equipment, simple adjustment procedure and switching between profiles, telescope and collimator implementations. There will be considered design basics of beam shapers, analysis of profile behaviour near focal plane, examples of implementations in micromachining systems and experimental DAC setups, results of profile measurements and material processing.

  5. Analytical strategies for uranium determination in natural water and industrial effluents samples; Estrategias analiticas para determinacao de uranio em amostras de aguas e efluentes industriais

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Juracir Silva

    2011-07-01

    The work was developed under the project 993/2007 - 'Development of analytical strategies for uranium determination in environmental and industrial samples - Environmental monitoring in the Caetite city, Bahia, Brazil' and made possible through a partnership established between Universidade Federal da Bahia and the Comissao Nacional de Energia Nuclear. Strategies were developed to uranium determination in natural water and effluents of uranium mine. The first one was a critical evaluation of the determination of uranium by inductively coupled plasma optical emission spectrometry (ICP OES) performed using factorial and Doehlert designs involving the factors: acid concentration, radio frequency power and nebuliser gas flow rate. Five emission lines were simultaneously studied (namely: 367.007, 385.464, 385.957, 386.592 and 409.013 nm), in the presence of HN0{sub 3}, H{sub 3}C{sub 2}00H or HCI. The determinations in HN0{sub 3} medium were the most sensitive. Among the factors studied, the gas flow rate was the most significant for the five emission lines. Calcium caused interference in the emission intensity for some lines and iron did not interfere (at least up to 10 mg L{sup -1}) in the five lines studied. The presence of 13 other elements did not affect the emission intensity of uranium for the lines chosen. The optimized method, using the line at 385.957 nm, allows the determination of uranium with limit of quantification of 30 {mu}g L{sup -1} and precision expressed as RSD lower than 2.2% for uranium concentrations of either 500 and 1000 {mu}g L{sup -1}. In second one, a highly sensitive flow-based procedure for uranium determination in natural waters is described. A 100-cm optical path flow cell based on a liquid-core waveguide (LCW) was exploited to increase sensitivity of the arsenazo 111 method, aiming to achieve the limits established by environmental regulations. The flow system was designed with solenoid micro-pumps in order to improve mixing and

  6. Preliminary Design Study of High-Power H2+ Cyclotrons for the DAEdALUS Experiment

    CERN Document Server

    Calabretta, L; Gammino, S; Rifuggiato, D; Ciavola, G; Maggiore, M; Piazza, L A C; Alonso, J R; Barletta, W A; Calanna, A; Conrad, J M

    2011-01-01

    This report provides a first design for H2+ accelerators as the DAEdALUS neutrino sources. A description of all aspects of the system, from the ion source to the extracted beam, is provided. The analysis provides a first proof of principle of a full cyclotron system which can provide the necessary beam power for the CP violation search proposed by the DAEdALUS Collaboration.

  7. Evaluation of the thermoluminescent detector answers of CaSO{sub 4}:Dy, LiF:Mg,Ti and micro LiF:Mg,Ti in photon clinical beams dosimetry using water simulator; Avaliacao da resposta de detectores termoluminescentes de CaSO4:Dy, LiF:Mg,Ti e microLiF:Mg,Ti na dosimetria de feixes clinicos de fotons utilizando simulador de agua

    Energy Technology Data Exchange (ETDEWEB)

    Matsushima, Luciana C.; Veneziani, Glauco R.; Campos, Leticia L., E-mail: lmatsushima@usp.b, E-mail: veneziani@ipen.b, E-mail: lcrodri@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (GMR/IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Gerencia de Metrologia das Radiacoes; Sakuraba, Roberto K.; Cruz, Jose C. da, E-mail: rsakuraba@einstein.b, E-mail: jccruz@einstein.b [Sociedade Beneficente Israelita Brasileira, Sao Paulo, SP (Brazil). Hospital Albert Einstein (HAE)

    2011-10-26

    This paper perform the comparative study of thermoluminescent answer of calcium sulfate dosemeter doped with dysprosium (DaSO{sub 4}:Dy) produced by the IPEN, Sao Paulo, with answer of lithium fluoride dosemeters doped with magnesium and titanium (LiF:Mg, Ti) in the dosimetry of clinical beams of photons (6 and 15 MV) by using water simulator object. Dose-answer curves were obtained for gamma radiation of cobalt-60 in the air and in conditions of electronic equilibrium (plate of PMMA), and clinical photons of CLINAC model 2100C accelerators of the two evaluated hospitals: Hospital das Clinicas of the Faculty of Medicine of Sao Paulo university and Hospital Albert Einstein. It was also evaluated the sensitivity and reproduction of the three dosemeters

  8. Laser Beam Focus Analyser

    DEFF Research Database (Denmark)

    Nielsen, Peter Carøe; Hansen, Hans Nørgaard; Olsen, Flemming Ove

    2007-01-01

    The quantitative and qualitative description of laser beam characteristics is important for process implementation and optimisation. In particular, a need for quantitative characterisation of beam diameter was identified when using fibre lasers for micro manufacturing. Here the beam diameter limits...... the obtainable features in direct laser machining as well as heat affected zones in welding processes. This paper describes the development of a measuring unit capable of analysing beam shape and diameter of lasers to be used in manufacturing processes. The analyser is based on the principle of a rotating...... mechanical wire being swept through the laser beam at varying Z-heights. The reflected signal is analysed and the resulting beam profile determined. The development comprised the design of a flexible fixture capable of providing both rotation and Z-axis movement, control software including data capture...

  9. KEKB beam instrumentation systems

    Science.gov (United States)

    Arinaga, M.; Flanagan, J.; Hiramatsu, S.; Ieiri, T.; Ikeda, H.; Ishii, H.; Kikutani, E.; Mimashi, T.; Mitsuhashi, T.; Mizuno, H.; Mori, K.; Tejima, M.; Tobiyama, M.

    2003-02-01

    For the stable high-luminosity operation and luminosity increase, the electron and positron storage rings of the KEK B-Factory (KEKB) is equipped with various beam instrumentations, which have been working well since the start of the commissioning in December, 1998. Details and performance of the beam-position monitor system based on the spectrum analysis using DSPs, the turn-by-turn BPM with four-dimensional function available for measurements of the individual bunch position, phase and intensity, the parametric beam-DCCTs designed so as to avoid the magnetic-core-selection problems for the parametric flux modulation, the bunch-by-bunch feedback system indispensable to suppress the strong multibunch instabilities in KEKB, the various optical beam diagnostic systems, such as synchrotron radiation interferometers for precise beam-size measurement, the tune meters, the bunch length monitors and the beam-loss monitors are described. Delicate machine tuning of KEKB is strongly supported by these instrumentations.

  10. Resolving Two Beams in Beam Splitters with a Beam Position Monitor

    Science.gov (United States)

    Kurennoy, Sergey

    2002-04-01

    The beam transport system for the Advanced Hydrotest Facility (AHF) anticipates multiple beam splitters. Monitoring two transversely separated beams in a common beam pipe in the splitter sections imposes certain requirements on beam diagnostics for these sections. We explore a two-beam system in a generic beam monitor and study the feasibility of resolving the transverse positions of the two beams with one diagnostics device. Effects of unequal beam currents and of finite transverse sizes of the beams are explored analytically for both the ultra relativistic case and the long-wavelength limit.

  11. Chilled beam application guidebook

    CERN Document Server

    Butler, David; Gräslund, Jonas; Hogeling, Jaap; Lund Kristiansen, Erik; Reinikanen, Mika; Svensson, Gunnar

    2007-01-01

    Chilled beam systems are primarily used for cooling and ventilation in spaces, which appreciate good indoor environmental quality and individual space control. Active chilled beams are connected to the ventilation ductwork, high temperature cold water, and when desired, low temperature hot water system. Primary air supply induces room air to be recirculated through the heat exchanger of the chilled beam. In order to cool or heat the room either cold or warm water is cycled through the heat exchanger.

  12. Hyperon beam physics

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, P.S.

    1996-03-01

    This report reviews the present status and recent results in hyperon physics concentrating on results from high energy hyperon beam experiments performed at Fermilab over the past several years. The report focuses on hyperon production polarization, precision hyperon magnetic moment measurements and radiative decay studies. Modern charged hyperon beam experiments are characterized by {approx}100m long apparatus and hyperon beams with {gamma}{sub Y}{approx}100 and hyperon fluxes in the 1-100 kHz range.

  13. The MECO muon beam

    Energy Technology Data Exchange (ETDEWEB)

    Bachman, M. [Department of Physics and Astronomy, University of California at Irvine, Irvine, California 92697--4575 (United States)

    1998-08-01

    The muon beam required by MECO, a muon conversion experiment, has been studied and simulated using GEANT3. The beam selects low energy, negative muons sufficient to perform a measurement of muon conversion to a level of 10{sup {minus}16} by relying on a graded magnetic solenoidal field and a curved transport solenoid equipped with collimators. Some details of the beam and simulation are discussed. {copyright} {ital 1998 American Institute of Physics.}

  14. Mechanically reinforced glass beams

    DEFF Research Database (Denmark)

    Nielsen, Jens Henrik; Olesen, John Forbes

    2007-01-01

    to breakage without any warning or ductility, which can be catastrophic if no precautions are taken. One aspect of this issue is treated here by looking at the possibility of mechanically reinforcing glass beams in order to obtain ductile failure for such a structural component. A mechanically reinforced...... the mechanical behavior of the beam is explained. Finally, some design criterions for reinforced glass beams are discussed....

  15. Beam Instrumentation and Diagnostics

    CERN Document Server

    Strehl, Peter

    2006-01-01

    This treatise covers all aspects of the design and the daily operations of a beam diagnostic system for a large particle accelerator. A very interdisciplinary field, it involves contributions from physicists, electrical and mechanical engineers and computer experts alike so as to satisfy the ever-increasing demands for beam parameter variability for a vast range of operation modi and particles. The author draws upon 40 years of research and work, most of them spent as the head of the beam diagnostics group at GSI. He has illustrated the more theoretical aspects with many real-life examples that will provide beam instrumentation designers with ideas and tools for their work.

  16. Beam cavity interaction

    CERN Document Server

    Gamp, A

    2011-01-01

    We begin by giving a description of the rf generator-cavity-beam coupled system in terms of basic quantities. Taking beam loading and cavity detuning into account, expressions for the cavity impedance as seen by the generator and as seen by the beam are derived. Subsequently methods of beam-loading compensation by cavity detuning, rf feedback, and feed-forward are described. Examples of digital rf phase and amplitude control for the special case of superconducting cavities are also given. Finally, a dedicated phase loop for damping synchrotron oscillations is discussed.

  17. Plasma Beam Measurements

    Science.gov (United States)

    1991-08-01

    GUN PLASMA BEAM / ,I 21 cm diameter = 0 GLASS DRIFT TUBE 50 cm diameter MCP CAMERA CLASS CROSSES (a) Gun muzzle /"- PLASA BEAM / TAROT z = 10 m MCP...discusses some of the hydrodynamic issues related to the calcula- tions. The reader may well wonder why hydrodynamics should be an issue in a 116 WL-TR-90...answer is yes for the slow beam cases and no for the fast beam cases. This is explained further. 118 WL-TR-90-83 The reader will recall the

  18. ALFA beam halo

    CERN Document Server

    Komarek, Tomas

    2014-01-01

    This note serves as a final report about CERN Summer Student Programme 2014 project. The beam halo is an undesired phenomenon for physics analyses on particle accelerators. It surrounds the beam core and constitutes an important part of background for signal measurements on some detectors, eg. in the forward region. In this study, the data from the ALFA detector were used, specifically from the run 191373 ($\\beta^*=90\\unit{m}$) and the run 213268 ($\\beta^*=1\\unit{km}$). Using the ROOT framework, a software for beam halo events selection was created and beam halo properties were examined. In the run 213268, excessive beam halo is suspected to be the reason for multiple beam scrapings that occurred. A kinematic reconstruction of beam halo particles is attempted in order to understand beam halo properties in the interaction point. Some further simulations are employed to find constraints for beam halo particles in order to survive in the accelerator for a longer time/many revolutions. This work represents a st...

  19. (Pulsed electron beam precharger)

    Energy Technology Data Exchange (ETDEWEB)

    Finney, W.C. (ed.); Shelton, W.N.

    1990-01-01

    This report discusses the following topics on electron beam guns: Precharger Modification; Installation of Charge vs. Radius Apparatus; High Concentration Aerosol Generation; and Data Acquisition and Analysis System.

  20. Simulation of Beam-Beam Background at CLIC

    CERN Document Server

    Sailer, A

    2010-01-01

    The dense beams used at CLIC to achieve a high luminosity will cause a large amount of background particles through beam-beam interactions. Generator level studies with GUINEAPIG and full detector simulation studies with an ILD based CLIC detector have been performed to evaluate the amount of beam-beam back- ground hitting the vertex detector.

  1. Employment of MCNP in the study of TLDS 600 and 700 seeking the implementation of radiation beam characterization of BNCT facility at IEA-R1; Emprego do MCNP no estudo dos TLDS 600 e 700 visando a implementacao da caracterizacao do feixe de irradiacao da instalacao de BNCT do IEA-R1

    Energy Technology Data Exchange (ETDEWEB)

    Cavalieri, Tassio Antonio

    2013-07-01

    Boron Neutron Capture Therapy, BNCT, is a bimodal radiotherapy procedure for cancer treatment. Its useful energy comes from a nuclear reaction driven by impinging thermal neutron upon Boron 10 atoms. A BNCT research facility has been constructed in IPEN at the IEA-R1 reactor, to develop studies in this area. One of its prime experimental parameter is the beam dosimetry which is nowadays made by using activation foils, for neutron measurements, and TLD 400, for gamma dosimetry. For mixed field dosimetry, the International Commission on Radiation Units and Measurements, ICRU, recommends the use of pair of detectors with distinct responses to the field components. The TLD 600/ TLD 700 pair meets this criteria, as the amount of {sup 6}Li, a nuclide with high thermal neutron cross section, greatly differs in their composition. This work presents a series of experiments and simulations performed in order to implement the mixed field dosimetry based on the use of TLD 600/TLD 700 pair. It also intended to compare this mixed field dosimetric methodology to the one so far used by the BNCT research group of IPEN. The response of all TLDs were studied under irradiations in different irradiation fields and simulations, underwent by MCNP, were run in order to evaluate the dose contribution from each field component. Series of repeated irradiations under pure gamma field and mixed field neutron/gamma field showed differences in the TLD individual responses which led to the adoption of a Normalization Factor. It has allowed to overcome TLD selection. TLD responses due to different field components and spectra were studied. It has shown to be possible to evaluate the relative gamma/neutron fluxes from the relative responses observed in the two Regions of Interest, ROIs, from TLD 600 and TLD 700. It has also been possible to observe the TLD 700 response to neutron, which leads to a gamma dose overestimation when one follows the ICRU recommended mixed field dosimetric procedure. Dose

  2. Resolving Two Beams in Beam Splitters with a Beam Position Monitor

    CERN Document Server

    Kurennoy, S S

    2002-01-01

    The beam transport system for the Advanced Hydrotest Facility (AHF) anticipates multiple beam splitters [1]. Monitoring two separated beams in a common beam pipe in the splitter sections imposes certain requirements on diagnostics for these sections. In this note we explore a two-beam system in a generic beam monitor and study the feasibility of resolving the positions of the two beams with a single diagnostic device.

  3. Implementation of depolarization due to beam-beam effects in the beam-beam interaction simulation tool GUINEA-PIG++

    Science.gov (United States)

    Rimbault, C.; Le Meur, G.; Blampuy, F.; Bambade, P.; Schulte, D.

    2009-12-01

    Depolarization is a new feature in the beam-beam simulation tool GUINEA-PIG++ (GP++). The results of this simulation are studied and compared with another beam-beam simulation tool, CAIN, considering different beam parameters for the International Linear Collider (ILC) with a centre-of-mass energy of 500 GeV.

  4. Beam distribution reconstruction simulation for electron beam probe

    CERN Document Server

    Feng, Yongchun; Li, Peng; Kang, Xincai; Yin, Yan; Liu, Tong; You, Yaoyao; Chen, Yucong; Zhao, Tiecheng; Xu, Zhiguo; Wang, Yanyu; Yuan, Youjin

    2016-01-01

    Electron beam probe (EBP) is a new principle detector, which makes use of a low-intensity and low-energy electron beam to measure the transverse profile, bunch shape, beam neutralization and beam wake field of an intense beam with small dimensions. While can be applied to many aspects, we limit our analysis to beam distribution reconstruction. This kind of detector is almost non-interceptive for all of the beam and does not disturb the machine environment. In this paper, we present the theoretical aspects behind this technique for beam distribution measurement and some simulation results of the detector involved. First, a method to obtain parallel electron beam is introduced and a simulation code is developed. And then, EBP as a profile monitor for dense beam is simulated using fast scan method under various target beam profile, such as KV distribution, waterbag distribution, parabolic distribution, Gaussian distribution and halo distribution. Profile reconstruction from the deflected electron beam trajectory...

  5. Linearizing Intra-Train Beam-Beam Deflection Feedback

    Energy Technology Data Exchange (ETDEWEB)

    Smith, S.R.; /SLAC

    2006-02-22

    Beam-beam deflection feedback acting within the crossing time of a single bunch train may be needed to keep linear collider beams colliding at high luminosity. In a short-pulse machine such as the Next Linear Collider (NLC) this feedback must converge quickly to be useful. The non-linear nature of beam-beam deflection vs. beam-beam offset in these machines precludes obtaining both rapid convergence and a stable steady-state lock to beam offsets with a linear feedback algorithm. We show that a simply realizable programmable non-linear amplifier in the feedback loop can linearize the feedback loop, approximately compensating the beam-beam deflection non-linearity. Performance of a prototype non-linear amplifier is shown. Improvement of convergence and stability of the beam-beam feedback loop is simulated.

  6. Beaming teaching application

    DEFF Research Database (Denmark)

    Markovic, Milos; Madsen, Esben; Olesen, Søren Krarup;

    2012-01-01

    BEAMING is a telepresence research project aiming at providing a multimodal interaction between two or more participants located at distant locations. One of the BEAMING applications allows a distant teacher to give a xylophone playing lecture to the students. Therefore, rendering of the xylophon...

  7. Ionization beam scanner

    CERN Multimedia

    CERN PhotoLab

    1973-01-01

    Inner structure of an ionization beam scanner, a rather intricate piece of apparatus which permits one to measure the density distribution of the proton beam passing through it. On the outside of the tank wall there is the coil for the longitudinal magnetic field, on the inside, one can see the arrangement of electrodes creating a highly homogeneous transverse electric field.

  8. Muon Beam at the Fermilab Test Beam Area

    CERN Document Server

    Denisov, Dmitri; Lukić, Strahinja; Ujić, Predrag

    2016-01-01

    The intensities and profiles of the muon beam behind the beam dump of the Fermilab test beam area when the facility is running in the "pion" beam mode are measured and summarized in this note. This muon beam with momenta in the range 10 - 50 GeV/c provides an opportunity to perform various measurements in parallel with other users of the test beam area.

  9. Mechanically reinforced glass beams

    DEFF Research Database (Denmark)

    Nielsen, Jens Henrik; Olesen, John Forbes

    2007-01-01

    The use of glass as a load carrying material in structural elements is rarely seen even though glass is a popular material for many architects. This is owed to the unreliable and low tensile strength, which is due to surface flaws and high brittleness of the material. These properties lead...... to breakage without any warning or ductility, which can be catastrophic if no precautions are taken. One aspect of this issue is treated here by looking at the possibility of mechanically reinforcing glass beams in order to obtain ductile failure for such a structural component. A mechanically reinforced...... laminated float glass beam is constructed and tested in four-point bending. The beam consist of 4 layers of glass laminated together with a slack steel band glued onto the bottom face of the beam. The glass parts of the tested beams are \\SI{1700}{mm} long and \\SI{100}{mm} high, and the total width of one...

  10. Beam director design report

    Energy Technology Data Exchange (ETDEWEB)

    Younger, F.C.

    1986-08-01

    A design and fabrication effort for a beam director is documented. The conceptual design provides for the beam to pass first through a bending and focusing system (or ''achromat''), through a second achromat, through an air-to-vacuum interface (the ''beam window''), and finally through the vernier steering system. Following an initial concept study for a beam director, a prototype permanent magnet 30/sup 0/ beam-bending achromat and prototype vernier steering magnet were designed and built. In volume II, copies are included of the funding instruments, requests for quotations, purchase orders, a complete set of as-built drawings, magnetic measurement reports, the concept design report, and the final report on the design and fabrication project. (LEW)

  11. Entangled vector vortex beams

    Science.gov (United States)

    D'Ambrosio, Vincenzo; Carvacho, Gonzalo; Graffitti, Francesco; Vitelli, Chiara; Piccirillo, Bruno; Marrucci, Lorenzo; Sciarrino, Fabio

    2016-09-01

    Light beams having a vectorial field structure, or polarization, that varies over the transverse profile and a central optical singularity are called vector vortex (VV) beams and may exhibit specific properties such as focusing into "light needles" or rotation invariance. VV beams have already found applications in areas ranging from microscopy to metrology, optical trapping, nano-optics, and quantum communication. Individual photons in such beams exhibit a form of single-particle quantum entanglement between different degrees of freedom. On the other hand, the quantum states of two photons can be also entangled with each other. Here, we combine these two concepts and demonstrate the generation of quantum entanglement between two photons that are both in VV states: a form of entanglement between two complex vectorial fields. This result may lead to quantum-enhanced applications of VV beams as well as to quantum information protocols fully exploiting the vectorial features of light.

  12. BEAMS3D Neutral Beam Injection Model

    Science.gov (United States)

    McMillan, Matthew; Lazerson, Samuel A.

    2014-09-01

    With the advent of applied 3D fields in Tokamaks and modern high performance stellarators, a need has arisen to address non-axisymmetric effects on neutral beam heating and fueling. We report on the development of a fully 3D neutral beam injection (NBI) model, BEAMS3D, which addresses this need by coupling 3D equilibria to a guiding center code capable of modeling neutral and charged particle trajectories across the separatrix and into the plasma core. Ionization, neutralization, charge-exchange, viscous slowing down, and pitch angle scattering are modeled with the ADAS atomic physics database. Elementary benchmark calculations are presented to verify the collisionless particle orbits, NBI model, frictional drag, and pitch angle scattering effects. A calculation of neutral beam heating in the NCSX device is performed, highlighting the capability of the code to handle 3D magnetic fields. Notice: this manuscript has been authored by Princeton University under Contract Number DE-AC02-09CH11466 with the US Department of Energy. The United States Government retains and the publisher, by accepting the article for publication, acknowledges that the United States Government retains a non-exclusive, paid-up, irrevocable, world-wide license to publish or reproduce the published form of this manuscript, or allow others to do so, for United States Government purposes.

  13. Multi-Beam Optical Tweezers

    OpenAIRE

    Glückstad, Jesper; Eriksen, Rene Lynge; Hanson, Steen Grüner

    2003-01-01

    A set of multi-beam electromagnetic tweezers is provided comprising a multi-beam generator for emission of a plurality of electromagnetic beams, at least some of the electromagnetic beams intersecting each other, or, having an individually controlled polarization whereby the position and/or angular orientation of a plurality of micro-objects may be individually controlled.A set of multi-beam electromagnetic tweezers is provided comprising a multi-beam generator for emission of a plurality of ...

  14. Beam Imaging and Luminosity Calibration

    CERN Document Server

    Klute, Markus; Salfeld-Nebgen, Jakob

    2016-01-01

    We discuss a method to reconstruct two-dimensional proton bunch densities using vertex distributions accumulated during LHC beam-beam scans. The $x$-$y$ correlations in the beam shapes are studied and an alternative luminosity calibration technique is introduced. We demonstrate the method on simulated beam-beam scans and estimate the uncertainty on the luminosity calibration associated to the beam-shape reconstruction to be below 1\\%.

  15. Analysis of the influence of well spacing on the injection rate behaviour for water injection under fracturing conditions; Analise da influencia do espacamento de pocos na determinacao da vazao de injecao para o processo de injecao com pressao cima da pressao de fratura

    Energy Technology Data Exchange (ETDEWEB)

    Munoz Mazo, Eduin Orlando [Universidade Estadual de Campinas (UNICAMP), SP (Brazil). Centro de Estudo do Petroleo. Lab. de Simulacao de Fluxo em Meios Porosos (UNISIM); Costa, Odair Jose; Schiozer, Denis Jose [Universidade Estadual de Campinas (UNICAMP), SP (Brazil). Faculdade de Engenharia Mecanica. Dept. de Engenharia de Petroleo

    2008-07-01

    Water injection under fracturing conditions is a proved manner of overcoming injectivity loss in reservoirs affected by formation damage. Nevertheless, as shown by Munoz Mazo et al. (2006), there is the possibility of the generated and propagated fractures intercept the producer wells making that the injected water shall be re-circulated into the reservoir instead of its main function which is to drive the oil contained in the reservoir pore space. The objective of this work is to determine the influence of well spacing on the determination of the water injection rate under fracturing conditions, aiming to study its effects on the production performance and the sweep efficiency. To accomplish the work, an analytical model for representing the absolute permeability reduction near the wellbore and a model which reproduces the fracture propagation in a coupled manner are used. In this way the model sensitivity to several well spacing and the injection rate effects are analyzed using the Net Present Value and the sweep efficiency is evaluated as a function of the Recovery Factor. The results show that the water injection under fracturing conditions is an effective way of overcoming the injectivity loss problem and evidence its sensitivity to different spacing between the injector and the producer wells. (author)

  16. Use of cyclic voltammetry and electrochemical impedance spectroscopy for determination of active surface area of modified carbon-based electrodes; Uso da voltametria ciclica e da espectroscopia de impedancia eletroquimica na determinacao da area superficial ativa de eletrodos modificados a base de carbono

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Leticia Lopes de

    2011-07-01

    Carbon-based electrodes as well the ion exchange electrodes among others have been applied mainly in the treatment of industrial effluents and radioactive wastes. Carbon is also used in fuel cells as substrate for the electrocatalysts, having high surface area which surpasses its geometric area. The knowledge of the total active area is important for the determination of operating conditions of an electrochemical cell with respect to the currents to be applied (current density). In this study it was used two techniques to determine the electrochemical active surface area of glassy carbon, electrodes and ion exchange electrodes: cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The experiments were carried out with KNO{sub 3} 0.1 mol.L{sup -1} solutions in a three-electrode electrochemical cell: carbon-based working electrode, platinum auxiliary electrode and Ag/AgCl reference electrode. The glassy carbon and porous carbon electrodes with geometric areas of 3.14 x 10{sup -2} and 2.83 X 10{sup -1} cm{sup 2}, respectively, were used. The ion exchange electrode was prepared by mixing graphite, carbon, ion exchange resin and a binder, and this mixture was applied in three layers on carbon felt, using a geometric area of 1.0 cm{sup 2} during the experiments. The capacitance (Cd) of the materials was determined by EIS using Bode diagrams. The value of 172 {mu}F.cm{sup -2} found for the glassy carbon is consistent with the literature data ({approx} 200 {mu}F.cm'-{sup 2}). By VC, varying the scan rate from 0.2 to 2.0 mV.s-1, the capacitance CdS (S = active surface area) in the region of the electric double layer (EDL) of each material was determined. By EIS, the values of C{sub d}, 3.0 x 10{sup -5} {mu}F.cm'-{sup 2} and 11 x 10{sup 3} {mu}F.cm-2, were found for the porous carbon and ion exchange electrodes, respectively, which allowed the determination of active surface areas as 3.73 x 106 cm{sup 2} and 4.72 cm{sup 2}. To sum up, the combined use of EIS and CV techniques is a valuable tool for the calculation of active surface areas of carbon-based electrodes. (author)

  17. Medidas lineares dos estágios de desenvolvimento da dentição permanente humana usando Tomografia Computadorizada de Feixe Cônico: um estudo preliminar Linear measurements of human permanent dental development stages using Cone-Beam Computed Tomography: a preliminary study

    Directory of Open Access Journals (Sweden)

    Carlos Estrela

    2010-10-01

    Full Text Available OBJETIVO: determinar as medidas lineares dos estágios de desenvolvimento da dentição permanente humana, usando tomografia computadorizada de feixe cônico (TCFC. MÉTODOS: este estudo foi desenvolvido a partir de bancos de dados de clínicas radiológicas privadas, envolvendo 18 pacientes (13 do sexo masculino, 5 do sexo feminino, com idades variando entre 3 e 20 anos. As imagens das TCFC foram obtidas por meio do sistema i-CAT e medidas com uma função específica do programa desse mesmo sistema. Duzentos e trinta e oito dentes foram analisados, em diferentes estágios de desenvolvimento, nos planos coronal e sagital. O método foi baseado na delimitação e mensuração das distâncias entre pontos anatômicos correspondentes ao desenvolvimento das coroas e raízes dentárias. A partir dos valores obtidos, pôde-se desenvolver um modelo quantitativo para se avaliar os estágios inicial e final de desenvolvimento para todos os grupos dentários. RESULTADOS E CONCLUSÕES: as medidas obtidas dos diferentes grupos dentários estão de acordo com as estimativas das investigações publicadas previamente. As imagens por TCFC dos diferentes estágios de desenvolvimento podem contribuir no diagnóstico, planejamento e resultado dos tratamentos em diversas especialidades odontológicas. As dimensões das coroas e das raízes dentárias podem ter importantes aplicações clínicas e em pesquisas, constituindo uma técnica não invasiva que contribui com estudos in vivo. Entretanto, mais estudos são recomendados a fim de minimizar possíveis variáveis metodológicas.OBJECTIVE: To determine the linear measurements of human permanent dentition development stages using Cone-Beam Computed Tomography. METHODS: This study was based on databases of private radiology clinics involving 18 patients (13 male and 5 female, with age ranging from 3 to 20 years. Cone-Beam Computed Tomography (CBCT images were acquired with i-CAT system and measured with a

  18. Multi-Beam Optical Tweezers

    DEFF Research Database (Denmark)

    2003-01-01

    A set of multi-beam electromagnetic tweezers is provided comprising a multi-beam generator for emission of a plurality of electromagnetic beams, at least some of the electromagnetic beams intersecting each other, or, having an individually controlled polarization whereby the position and/or angular...... orientation of a plurality of micro-objects may be individually controlled.A set of multi-beam electromagnetic tweezers is provided comprising a multi-beam generator for emission of a plurality of electromagnetic beams, at least some of the electromagnetic beams intersecting each other, or, having...

  19. Simulations of beam-beam and beam-wire interactions in RHIC

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyung J.; Sen, Tanaji; /Fermilab; Abreu, Natalia P.; Fischer, Wolfram; /Brookhaven

    2009-02-01

    The beam-beam interaction is one of the dominant sources of emittance growth and luminosity lifetime deterioration. A current carrying wire has been proposed to compensate long-range beam-beam effects in the LHC and strong localized long-range beam-beam effects are experimentally investigated in the RHIC collider. Tune shift, beam transfer function, and beam loss rate are measured in dedicated experiments. In this paper, they report on simulations to study the effect of beam-wire interactions based on diffusive apertures, beam loss rates, and beam transfer function using a parallelized weak-strong beam simulation code (BBSIMC). The simulation results are compared with measurements performed in RHIC during 2007 and 2008.

  20. Beam Purification by Photodetachment

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Yuan [ORNL; Beene, James R [ORNL; Havener, Charles C [ORNL; Galindo-Uribarri, Alfredo {nmn} [ORNL; Andersson, P. [University of Gothenburg, Sweden; Lindahl, A. O. [University of Gothenburg, Sweden; Hanstorp, D. [University of Gothenburg, Sweden; Forstner, Dr. Oliver [University of Vienna, Austria; Gottwald, T. [Johannes Gutenberg-Universitaet Mainz, Mainz, Germany; Wendt, K. [Johannes Gutenberg-Universitaet Mainz, Mainz, Germany

    2012-01-01

    Ion beam purity is of crucial importance to many basic and applied studies. Selective photodetachment has been proposed to suppress unwanted species in negative ion beams while preserving the intensity of the species of interest. A highly efficient technique based on photodetachment in a gas-filled radio frequency quadrupole ion cooler has been demonstrated. In off-line experiments with stable ions, up to 104 times suppression of the isobar contaminants in a number of interesting radioactive negative ion beams has been demonstrated. For selected species, this technique promises experimental possibilities in studies on exotic nuclei, accelerator mass spectrometry, and fundamental properties of negative atomic and molecular ions.

  1. Beam instrumentation performance overview

    CERN Document Server

    Sapinski, M

    2012-01-01

    The 2011 run has proven that LHC can operate safely and stably with higher bunch intensity and smaller transverse emittance than foreseen in the Technical Design Report. In this presentation the performance of the Beam Position Monitoring (BPM) system is discussed. The improvements to the system, those made during the last year and those expected to be done for 2012 run are presented. The status of the three types of devices measuring the transverse beam emittance, wire scanners (BWS), synchrotron radiation monitors (BSRT) and beam gas ionization monitors (BGI), are shown. The control room applications are reviewed and a set of improvements proposed by the operation team is presented.

  2. LEDA beam diagnostics instrumentation: Beam position monitors

    Science.gov (United States)

    Barr, D.; Day, L.; Gilpatrick, J. D.; Kasemir, K.-U.; Martinez, D.; Power, J. F.; Shurter, R.; Stettler, M.

    2000-11-01

    The Low Energy Demonstration Accelerator (LEDA) facility located at Los Alamos National Laboratory (LANL) accelerates protons to an energy of 6.7 MeV and current of 100 mA operating in either a pulsed or cw mode. Of key importance to the commissioning and operations effort is the Beam Position Monitor system (BPM). The LEDA BPM system uses five micro-stripline beam position monitors processed by log ratio processing electronics with data acquisition via a series of custom TMS320C40 Digital Signal Processing (DSP) boards. Of special interest to this paper is the operation of the system, the log ratio processing, and the system calibration technique. This paper will also cover the DSP system operations and their interaction with the main accelerator control system.

  3. Leda Beam Diagnostics Instrumentation Beam Position Monitors

    CERN Document Server

    Barr, D

    2000-01-01

    The Low Energy Demonstration Accelerator (LEDA) facility located at Los Alamos National Laboratory (LANL) accelerates protons to an energy of 6.7-MeV and current of 100-mA operating in either a pulsed or cw mode. Of key importance to the commissioning and operations effort is the Beam Position Monitor system (BPM). The LEDA BPM system uses five micro-stripline beam position monitors processed by log ratio processing electronics with data acquisition via a series of custom TMS32OC40 Digital Signal Processing (DSP) boards. Of special interest to this paper is the operation of the system, the log ratio processing, and the system calibration technique. This paper will also cover the DSP system operations and their interaction with the main accelerator control system.

  4. HIRENASD Beam FEM

    Data.gov (United States)

    National Aeronautics and Space Administration — This contains attempts to create BEAM FEM model. I have started a Blog to discuss this... please put your comments there and I will attempt to keep everything...

  5. External Beam Therapy (EBT)

    Science.gov (United States)

    ... Esophageal Cancer Treatment Head and Neck Cancer Treatment Lung Cancer Treatment Prostate Cancer Treatment Brain Tumor Treatment Why is ... Radiation Oncology) Breast Cancer Treatment Esophageal Cancer Treatment Lung Cancer Treatment Images related to External Beam Therapy (EBT) Sponsored ...

  6. Final focus test beam

    Energy Technology Data Exchange (ETDEWEB)

    1991-03-01

    This report discusses the following: the Final Focus Test Beam Project; optical design; magnets; instrumentation; magnetic measurement and BPM calibration; mechanical alignment and stabilization; vacuum system; power supplies; control system; radiation shielding and personnel protection; infrastructure; and administration.

  7. Electron Beam Ion Sources

    CERN Document Server

    Zschornacka, G.; Thorn, A.

    2013-12-16

    Electron beam ion sources (EBISs) are ion sources that work based on the principle of electron impact ionization, allowing the production of very highly charged ions. The ions produced can be extracted as a DC ion beam as well as ion pulses of different time structures. In comparison to most of the other known ion sources, EBISs feature ion beams with very good beam emittances and a low energy spread. Furthermore, EBISs are excellent sources of photons (X-rays, ultraviolet, extreme ultraviolet, visible light) from highly charged ions. This chapter gives an overview of EBIS physics, the principle of operation, and the known technical solutions. Using examples, the performance of EBISs as well as their applications in various fields of basic research, technology and medicine are discussed.

  8. Optical solenoid beams

    National Research Council Canada - National Science Library

    Lee, Sang-Hyuk; Roichman, Yohai; Grier, David G

    2010-01-01

    We introduce optical solenoid beams, diffractionless solutions of the Helmholtz equation whose diffraction-limited in-plane intensity peak spirals around the optical axis, and whose wavefronts carry...

  9. Pulsed electron beam precharger

    Energy Technology Data Exchange (ETDEWEB)

    Finney, W.C. (ed.); Shelton, W.N.

    1991-01-01

    Electron beam precharging of a high resistivity aerosol was successfully demonstrated during this reporting period (Quarters Five and Six). The initial E-beam particle precharging experiments completed this term were designed to confirm and extend some of the work performed under the previous contract. There are several reasons for doing this: (1) to re-establish a baseline performance criterion for comparison to other runs, (2) to test several recently upgraded or repaired subsystems, and (3) to improve upon the collection efficiency of the electron beam precipitator when testing precharging effectiveness with a very high resistivity, moderate-to-high concentration dust load. In addition, these shakedown runs were used to determine a set of suitable operational parameters for the wind tunnel, the electrostatic collecting sections, and the MINACC E-beam accelerator. These parameters will generally be held constant while the precharging parameters are varied to produce an optimum particle charge.

  10. Transverse Beam Size Effects in Beam Position Monitors

    Science.gov (United States)

    Kurennoy, Sergey

    2001-04-01

    The fields produced by a long beam with a given transverse charge distribution in a homogeneous vacuum chamber are studied. Signals induced by the displaced finite-size beam on electrodes of a beam position monitor (BPM) are calculated and compared to those from a pencil beam. The corrections to BPM signals due to a finite beam size are found analytically for a few particular transverse distributions of the beam current. The results for fields can also be directly applied for calculating the beam coupling impedances of small discontinuities.

  11. Measurement Error Effects of Beam Parameters Determined by Beam Profiles

    CERN Document Server

    Jang, Ji-Ho; Jeon, Dong-O

    2015-01-01

    A conventional method to determine beam parameters is using the profile measurements and converting them into the values of twiss parameters and beam emittance at a specified position. The beam information can be used to improve transverse beam matching between two different beam lines or accelerating structures. This work is related with the measurement error effects of the beam parameters and the optimal number of profile monitors in a section between MEBT (medium energy beam transport) and QWR (quarter wave resonator) of RAON linear accelerator.

  12. SPIDER beam dump as diagnostic of the particle beam

    Science.gov (United States)

    Zaupa, M.; Dalla Palma, M.; Sartori, E.; Brombin, M.; Pasqualotto, R.

    2016-11-01

    The beam power produced by the negative ion source for the production of ion of deuterium extracted from RF plasma is mainly absorbed by the beam dump component which has been designed also for measuring the temperatures on the dumping panels for beam diagnostics. A finite element code has been developed to characterize, by thermo-hydraulic analysis, the sensitivity of the beam dump to the different beam parameters. The results prove the capability of diagnosing the beam divergence and the horizontal misalignment, while the entity of the halo fraction appears hardly detectable without considering the other foreseen diagnostics like tomography and beam emission spectroscopy.

  13. SPIDER beam dump as diagnostic of the particle beam

    Energy Technology Data Exchange (ETDEWEB)

    Zaupa, M., E-mail: matteo.zaupa@igi.cnr.it; Sartori, E. [Università degli Studi di Padova, Via 8 Febbraio 2, Padova 35122 (Italy); Consorzio RFX, Corso Stati Uniti 4, Padova 35127 (Italy); Dalla Palma, M.; Brombin, M.; Pasqualotto, R. [Consorzio RFX, Corso Stati Uniti 4, Padova 35127 (Italy)

    2016-11-15

    The beam power produced by the negative ion source for the production of ion of deuterium extracted from RF plasma is mainly absorbed by the beam dump component which has been designed also for measuring the temperatures on the dumping panels for beam diagnostics. A finite element code has been developed to characterize, by thermo-hydraulic analysis, the sensitivity of the beam dump to the different beam parameters. The results prove the capability of diagnosing the beam divergence and the horizontal misalignment, while the entity of the halo fraction appears hardly detectable without considering the other foreseen diagnostics like tomography and beam emission spectroscopy.

  14. LHCb: Beam Pipe portrait

    CERN Multimedia

    LHCb, Collaboration

    2005-01-01

    The proton beams circulate in the accelerator in Ultra High Vacuum to make them interact only with each other when colliding at the interaction point. A special beam pipe "holds" the vacuum where they pass through the LHCb detector: it has to be mechanically very strong to stand the difference in pressure between the vacuum inside it and the air in the cavern but also be as transparent as possible for the particles originating in the proton−proton collisions.

  15. LHCb: Beam Pipe

    CERN Multimedia

    LHCb, Collaboration

    2005-01-01

    The proton beams circulate in the accelerator in Ultra High Vacuum to make them interact only with each other when colliding at the interaction point. A special beam pipe "holds" the vacuum where they pass through the LHCb detector:it has to be mechanically very strong to stand the difference in pressure between the vacuum inside it and the air in the cavern but also be as transparent as possible for the particles originating in the proton−proton collisions.

  16. Wire Scanner Beam Profile Measurements: LANSCE Facility Beam Development

    Energy Technology Data Exchange (ETDEWEB)

    Gilpatrick, John D. [Los Alamos National Laboratory; Batygin, Yuri K. [Los Alamos National Laboratory; Gonzales, Fermin [Los Alamos National Laboratory; Gruchalla, Michael E. [Los Alamos National Laboratory; Kutac, Vincent G. [Los Alamos National Laboratory; Martinez, Derwin [Los Alamos National Laboratory; Sedillo, James Daniel [Los Alamos National Laboratory; Pillai, Chandra [Los Alamos National Laboratory; Rodriguez Esparza, Sergio [Los Alamos National Laboratory; Smith, Brian G. [Los Alamos National Laboratory

    2012-05-15

    The Los Alamos Neutron Science Center (LANSCE) is replacing Wire Scanner (WS) beam profile measurement systems. Three beam development tests have taken place to test the new wire scanners under beam conditions. These beam development tests have integrated the WS actuator, cable plant, electronics processors and associated software and have used H{sup -} beams of different beam energy and current conditions. In addition, the WS measurement-system beam tests verified actuator control systems for minimum profile bin repeatability and speed, checked for actuator backlash and positional stability, tested the replacement of simple broadband potentiometers with narrow band resolvers, and tested resolver use with National Instruments Compact Reconfigurable Input and Output (cRIO) Virtual Instrumentation. These beam tests also have verified how trans-impedance amplifiers react with various types of beam line background noise and how noise currents were not generated. This paper will describe these beam development tests and show some resulting data.

  17. A Sintaxe da Janela

    Directory of Open Access Journals (Sweden)

    Luís Antônio Jorge

    1993-12-01

    Full Text Available A preocupação fundamenta! do trabalho é de caráter ontológico: esboçar o problema das significações apriorísticas e autônomas dos elementos que compõem a sintaxe arquitetônica. O trabalho elege um desses elementos: a janela. Este artigo parte da aproximação histórica entre a janela e a secção da pirâmide visual, construção imaginária da teoria da perspectiva renascentista. A consideração da janela na linguagem arquitetônica implica reconhecer uma ambigüidade essencial: a janela deve inserir-se ordenadamente no plano da parede - raciocínio típico da modenatura - mas também relacionar-se com a imagem vista através dela, que extrapola o plano, ressaltando a tridimensionalidade - herança da perspectiva renascentista, fundamentada no espaço euclidiano. Ver janela ou ver através da janela são alternativas que se colocam tanto ao observador interno ao edifício, quanto ao externo. Texto de duplaface, a sintaxe da janela versa sobre o relacionamento desses dois lados

  18. High power beam analysis

    Science.gov (United States)

    Aharon, Oren

    2014-02-01

    In various modern scientific and industrial laser applications, beam-shaping optics manipulates the laser spot size and its intensity distribution. However the designed laser spot frequently deviates from the design goal due to real life imperfections and effects, such as: input laser distortions, optical distortion, heating, overall instabilities, and non-linear effects. Lasers provide the ability to accurately deliver large amounts of energy to a target area with very high accuracy. Thus monitoring beam size power and beam location is of high importance for high quality results and repeatability. Depending on the combination of wavelength, beam size and pulse duration , laser energy is absorbed by the material surface, yielding into processes such as cutting, welding, surface treatment, brazing and many other applications. This article will cover the aspect of laser beam measurements, especially at the focal point where it matters the most. A brief introduction to the material processing interactions will be covered, followed by fundamentals of laser beam propagation, novel measurement techniques, actual measurement and brief conclusions.

  19. Beam and experiments: summary

    Energy Technology Data Exchange (ETDEWEB)

    Blondel, A.; Bueno, A.; Campanelli, M.; Cervera, A.; Cline, D.B.; Collot, J.; Jong, M. de; Donini, A.; Dydak, F. E-mail: friedrich.dydak@cern.ch; Edgecock, R.; Gavela, M.B.; Gomez-Cadenas, J.J.; Gonzalez-Garcia, M.C.; Gruber, P.; Harris, D.A.; Hernandez, P.; Kuno, Y.; Litchfield, P.J.; McFarland, K.; Mena, O.; Migliozzi, P.; Palladino, V.; Panman, J.; Papadopoulos, I.M.; Para, A.; Pena-Garay, C.; Perez, P.; Rigolin, S.; Romanino, A.; Rubbia, A.; Strolin, P.; Wojcicki, S

    2000-08-21

    The discovery of neutrino oscillations marks a major milestone in the history of neutrino physics, and opens a new window to the still mysterious origin of masses and flavour mixing. Many current and forthcoming experiments will answer open questions; however, a major step forward, up to and possibly including CP violation in the neutrino-mixing matrix, requires the neutrino beams from a neutrino factory. The neutrino factory is a new concept for producing neutrino beams of unprecedented quality in terms of intensity, flavour composition, and precision of the beam parameters. Most importantly, the neutrino factory is the only known way to generate a high-intensity beam of electron neutrinos of high energy. The neutrino beam from a neutrino factory, in particular the electron-neutrino beam, enables the exploration of otherwise inaccessible domains in neutrino oscillation physics by exploiting baselines of planetary dimensions. Suitable detectors pose formidable challenges but seem within reach with only moderate extrapolations from existing technologies. Although the main physics attraction of the neutrino factory is in the area of neutrino oscillations, an interesting spectrum of further opportunities ranging from high-precision, high-rate neutrino scattering to physics with high-intensity stopped muons comes with it.

  20. Beam-beam effects under the influence of external noise

    CERN Document Server

    Ohmi, K.

    2014-01-01

    Fast external noise, which gives fluctuation into the beam orbit, is discussed in connection with beam-beam effects. Phase noise from crab cavities and detection devices (position monitor) and kicker noise from the bunch by bunch feedback system are the sources. Beam-beam collisions with fast orbit fluctuations with turn by turn or multi-turn correlations, cause emittance growth and luminosity degradation. We discuss the tolerance of the noise amplitude for LHC and HL-LHC.

  1. 3D terahertz beam profiling

    DEFF Research Database (Denmark)

    Pedersen, Pernille Klarskov; Strikwerda, Andrew; Wang, Tianwu

    2013-01-01

    We present a characterization of THz beams generated in both a two-color air plasma and in a LiNbO3 crystal. Using a commercial THz camera, we record intensity images as a function of distance through the beam waist, from which we extract 2D beam profiles and visualize our measurements into 3D beam...

  2. Observation of Beam-beam Deflections with LHC Orbit Data

    CERN Document Server

    Kozanecki, W; Wenninger, J

    2013-01-01

    The LHC luminosity is calibrated in dedicated fills with van der Meer scans (vdM) of the beams that are performed repeatedly in both planes. During vdM scans the relative separation of the two LHC beams is scanned in a range of ±6 sigma , where sigma is the single beam size, probing the beam-beam deflection over a relatively large range. Orbit data logged parasitically during those scans were analysed and the beam-beam deflections at the IP being scanned could be reconstructed from orbit fits in the LHC arcs surrounding the IP. Despite the small size of the kicks (≤ 1μrad) the coherent beam-beam deflections are clearly resolved. The beam parameters that are extracted from the fit to the beam-beam deflection data were compared to luminosity data fits and they were found to be in good agreement. The closed orbit shift due to the beam-beam kick is also clearly observed in the beam position interpolation at the collision point.

  3. Beam Trail Tracking at Fermilab

    Energy Technology Data Exchange (ETDEWEB)

    Nicklaus, Dennis J. [Fermilab; Carmichael, Linden Ralph [Fermilab; Neswold, Richard [Fermilab; Yuan, Zongwei [Fermilab

    2015-01-01

    We present a system for acquiring and sorting data from select devices depending on the destination of each particular beam pulse in the Fermilab accelerator chain. The 15 Hz beam that begins in the Fermilab ion source can be directed to a variety of additional accelerators, beam lines, beam dumps, and experiments. We have implemented a data acquisition system that senses the destination of each pulse and reads the appropriate beam intensity devices so that profiles of the beam can be stored and analysed for each type of beam trail. We envision utilizing this data long term to identify trends in the performance of the accelerators

  4. Review of nondiffracting Bessel beams

    Science.gov (United States)

    Lapointe, Michael R.

    1991-01-01

    The theory of nondiffracting beam propagation and experimental evidence for nearly-nondiffractive Bessel beam propagation are reviewed. The experimental results are reinterpreted using simple optics formulas, which show that the observed propagation distances are characteristic of the optical systems used to generate the beams and do not depend upon the initial beam profiles. A set of simple experiments are described which support this interpretation. It is concluded that nondiffracting Bessel beam propagation has not yet been experimentally demonstrated.

  5. Genealogias da alegria

    Directory of Open Access Journals (Sweden)

    Bruno Vasconcelos de Almeid

    2009-08-01

    Full Text Available Genealogias da Alegria tem por objetivo rastrear conceitos e construir planos sobre os quais podemos pensar a alegria como campo problemático. Trata-se de traçar linhas e acoplar fragmentos históricos e literários com a finalidade de subsidiar a discussão contemporânea em torno da alegria. O procedimento genealógico vale-se de trechos das obras de Calímaco e Luciano de Samósata, da elegia erótica romana e da alegria cristã. O passo seguinte consiste em rastrear o pensamento da alegria na obra de Gilles Deleuze, especialmente em três momentos: uma passagem de Diferença e Repetição, um trecho dos Diálogos extraído de Da Superioridade da Literatura Anglo-americana e a comunicação Pensamento Nômade no Colóquio de Cerisy. A alegria não se define como sentimento ou emoção; ao contrário, está ligada à premissa de afirmação da vida e ao caráter trágico da existência.

  6. A sabedoria da democracia

    Directory of Open Access Journals (Sweden)

    Gilson Matilde Diana

    2010-01-01

    Full Text Available http://dx.doi.org/10.5007/1677-2954.2010v9n1p131Durante a maior parte da história, a democracia foi desprezada como uma forma política inferior – a regra do povo, ou “dos muitos”, era logo identificada como a regra da ralé, da escória. Herdando do povo a volubilidade e a instabilidade, a democracia estava sempre perigosamente próxima do arbítrio e da anarquia, com toda a violência que se costuma associar a isso.

  7. Beam-beam observations in the Relativistic Heavy Ion Collider

    Energy Technology Data Exchange (ETDEWEB)

    Luo, Y. [Brookhaven National Laboratory (BNL), Upton, NY (United States); Fischer, W. [Brookhaven National Laboratory (BNL), Upton, NY (United States); White, S. [Brookhaven National Laboratory (BNL), Upton, NY (United States)

    2015-06-24

    The Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Laboratory has been operating since 2000. Over the past decade, thanks to the continuously increased bunch intensity and reduced β*s at the interaction points, the maximum peak luminosity in the polarized proton operation has been increased by more than two orders of magnitude. In this article, we first present the beam-beam observations in the previous RHIC polarized proton runs. Then we analyze the mechanisms for the beam loss and emittance growth in the presence of beam-beam interaction. The operational challenges and limitations imposed by beam-beam interaction and their remedies are also presented. In the end, we briefly introduce head-on beam-beam compensation with electron lenses in RHIC.

  8. Beam Time Accounting

    CERN Document Server

    Seitova, Diana

    2016-01-01

    ISOLDE is one of the leading research facilities in the field of nuclear physics. A proton beam with an energy 1.4 GeV coming from the Proton Synchrotron Booster (PSB) hits one of the targets at ISOLDE and produces Radioactive Ion Beams (RIBs). Then, the RIBs of interest is selected and delivered to the different experimental stations. In order to deliver the beam to the certain experimental station, the positions of the devices along the beamline should satisfy certain conditions. The purpose of this project is to define the conditions for the beam to pass through the different beamlines and to store the data about device’s status for later analysis and statistics, so it would be possible to know when the beam was used for different experiments. The data with the settings of the different devices is saved in the Timber database and the first steps for making virtual devices to compile the status of the beamlines were completed.

  9. Bringing up beams

    CERN Multimedia

    Katarina Anthony

    2013-01-01

    Last month, commissioning began on CERN’s newest linear accelerator: Linac4. As the replacement machine for Linac2, Linac4 will take a negative hydrogen ion beam to a staggering 160 MeV. We check in to see how the Linac4 team is preparing its machine for its new role as the first link in the accelerator chain.   The Linac4 3 MeV beam line, with the ion source in the back, the RFQ in the middle and the chopping line in the front. On 14 November, members of the Linac4 collaboration and the CERN Operations Group were brought together for their first “real day” in the Linac4 Control Room. Together, they successfully accelerated their first hydrogen ion beam to 3 MeV. It was an exciting moment for everyone involved and marked the start of one of the most critical commissioning phases for the new accelerator. At the start of the Linac4 beam line sits the CERN-made Radio Frequency Quadrupole (RFQ). This vital piece of machinery takes the beam from 45 keV to 3 MeV in ju...

  10. Paul Collier : Balancing beams

    CERN Multimedia

    2009-01-01

    As former head of AB Operations, Paul Collier and his group were in the ‘cockpit’ for the LHC’s maiden voyage - piloting the first beam around the ring. But now, as Head of the Beams Department, he will need his feet firmly on the ground in order to balance all the beam activities at CERN. "As Department Head, I’ll have less direct contact with the machines," Collier says with a hint of regret. "I’ll still obviously be very involved, but they won’t actually let me loose in front of the keyboard anymore!" As the new Head of the BE Department, Collier will be in charge of nearly 400 people, and will oversee all the beam activities, including the preparations for the longest period of beam operation in the history of CERN. In the new organization, the BE, TE and EN Departments have been grouped together in the Accelerator and Technology Sector. "‘Partnership’ is a key word for the three departments," says Collier. "The n...

  11. ICFA Beam Dynamics Newsletter

    Energy Technology Data Exchange (ETDEWEB)

    Ben-Zvi I.; Kuczewski A.; Altinbas, Z.; Beavis, D.; Belomestnykh,; Dai, J. et al

    2012-07-01

    The Collider-Accelerator Department at Brookhaven National Laboratory is building a high-brightness 500 mA capable Energy Recovery Linac (ERL) as one of its main R&D thrusts towards eRHIC, the polarized electron - hadron collider as an upgrade of the operating RHIC facility. The ERL is in final assembly stages, with injection commisioning starting in October 2012. The objective of this ERL is to serve as a platform for R&D into high current ERL, in particular issues of halo generation and control, Higher-Order Mode (HOM) issues, coherent emissions for the beam and high-brightness, high-power beam generation and preservation. The R&D ERL features a superconducting laser-photocathode RF gun with a high quantum efficiency photoccathode served with a load-lock cathode delivery system, a highly damped 5-cell accelerating cavity, a highly flexible single-pass loop and a comprehensive system of beam instrumentation. In this ICFA Beam Dynamics Newsletter article we will describe the ERL in a degree of detail that is not usually found in regular publications. We will discuss the various systems of the ERL, following the electrons from the photocathode to the beam dump, cover the control system, machine protection etc and summarize with the status of the ERL systems.

  12. A better beam quality

    CERN Multimedia

    CERN Bulletin

    2010-01-01

    Progress has been made on two fronts, providing physics data and preparing for higher intensities. Over the Whitsun weekend of May 22 to 24, 5 fills for physics provided almost 30 hours of stable colliding beams, all with bunch intensities around 2x1010 protons and at a β* of 2m. The first three of these fills were with 6 bunches per beam, giving 3 pairs of collisions in all experiments. For the other two fills, the number of bunches per beam was increased to 13, giving 8 pairs of colliding bunches, and for the first time luminosities were pushed above 1029 cm-2s-1, 2 orders of magnitude higher than first collisions in March. In between and after these physics fills, nominal bunches of 1011 protons were successfully ramped and brought into collision in ATLAS and CMS for the first time (not in stable beam conditions and without squeeze). Event rates seen by the experiments were in the expected range for these conditions. In the middle of this work, a short fill with beams of 7 nominal bunches was ...

  13. Pulsed electron beam precharger

    Energy Technology Data Exchange (ETDEWEB)

    Finney, W.C. (ed.); Shelton, W.N.

    1990-01-01

    Electrostatic collection of a high resistivity aerosol using the Electron Beam Precipitator (EBP) collecting section was demonstrated during this reporting period (Quarter Five). Collection efficiency experiments were designed to confirm and extend some of the work performed under the previous contract. The reason for doing this was to attempt to improve upon the collection efficiency of the precipitator alone when testing with a very high resistivity, moderate-to-high concentration dust load. From the collector shakedown runs, a set of suitable operational parameters were determined for the downstream electrostatic collecting sections of the Electron Beam Precipitator wind tunnel. These parameters, along with those for the MINACC electron beam, will generally be held constant while the numerous precharging parameters are varied to produce an optimum particle charge. The electrostatic collector experiments were part of a larger, comprehensive investigation on electron beam precharging of high resistivity aerosol particles performed during the period covered by Quarters Five, Six, and Seven. This body of work used the same experimental apparatus and procedures and the experimental run period lasted nearly continuously for six months. A summary of the Quarter Five work is presented in the following paragraphs. Section II-A of TPR 5 contains a report on the continuing effort which was expended on the modification and upgrade of the pulsed power supply and the monitoring systems prior to the initiation of the electron beam precharging experimental work.

  14. Corporeidade da voz : estudo da vocalidade poetica

    OpenAIRE

    Fernando Manoel Aleixo

    2004-01-01

    Resumo: Este material é o resultado da investigação prática da voz realizada a partir do desenvolvimento do princípio da sabedoria sensível do corpo. O texto expõe as etapas percorridas no levantamento de experiências e reflexões pedagógicas sobre a voz do ator, no estabelecimento de referências sobre o corpo e o aprendizado sensível e, também, no processo de composição poética do espetáculo teatral Voz Mercê Abstract: This material springs from a practical investigative work on voice base...

  15. Modelagem da laringe: da biologia ao computador

    Directory of Open Access Journals (Sweden)

    Marcelo de Oliveira Rosa

    2016-01-01

    Full Text Available Neste trabalho apresentamos uma descrição daanatomia e fisiologia da laringe, enfatizando os aspectos relevantes à fonação. A partir destes aspectos, a modelagem da laringe é apresentada. O principal objetivo de modelara laringe é representar de uma maneira simples esse órgãoatravés de equações matemáticos intimamente relacionadoscom características fisiológicas. Equações aerodinâmicase viscoelásticas são simplificadas de acordo com as pesquisas,sempre buscando simplicidade e aplicabilidade computacional. Assim, pesquisadores podem compreender melhor a laringe e a fala humana em termos dos efeitos linguísticos, cirúrgicos e computacionais produzidos pelamovimentação desse órgão. Palavras-chave: Laringe, modelagem, sinal glotal,produção da fala.

  16. Beam-beam studies for FCC-hh

    CERN Document Server

    Barranco Garcia, Javier; Buffat, Xavier; Furuseth, Sondre Vik

    2017-01-01

    The Future Circular Collider hadron-hadron (FCC-hh) design study is currently exploring different IR design possibilities including round and flat optics or different crossing schemes. The present study intends to evaluate each scenario from the beam-beam effects point of view. In particular the single particle long term stability to maximize beam lifetimes and luminosity reach is used to quantify the differences. The impact of strong head on interactions on the beam quality and lifetime is addressed by means of GPU accelerated simulations code featuring a weak-strong 6-dimensional beam-beam interaction.

  17. Six-dimensional beam-beam kick including coupled motion

    Directory of Open Access Journals (Sweden)

    L. H. A. Leunissen

    2000-12-01

    Full Text Available The six-dimensional beam-beam interaction as developed in 1992 by Hirata, Moshammer, and Ruggiero has been extended to include linear coupled motion and an arbitrary crossing plane. The technique of symplectic mapping in the six-dimensional phase space, called synchrobeam mapping, is applied to investigate the beam-beam kick within a solenoid. A linear beam-beam model including coupling is discussed in detail, also in the framework of a six-dimensional symplectic dispersion formalism.

  18. Grazing incidence beam expander

    Energy Technology Data Exchange (ETDEWEB)

    Akkapeddi, P.R.; Glenn, P.; Fuschetto, A.; Appert, Q.; Viswanathan, V.K.

    1985-01-01

    A Grazing Incidence Beam Expander (GIBE) telescope is being designed and fabricated to be used as an equivalent end mirror in a long laser resonator cavity. The design requirements for this GIBE flow down from a generic Free Electron Laser (FEL) resonator. The nature of the FEL gain volume (a thin, pencil-like, on-axis region) dictates that the output beam be very small. Such a thin beam with the high power levels characteristic of FELs would have to travel perhaps hundreds of meters or more before expanding enough to allow reflection from cooled mirrors. A GIBE, on the other hand, would allow placing these optics closer to the gain region and thus reduces the cavity lengths substantially. Results are presented relating to optical and mechanical design, alignment sensitivity analysis, radius of curvature analysis, laser cavity stability analysis of a linear stable concentric laser cavity with a GIBE. Fabrication details of the GIBE are also given.

  19. Light Beam Generation

    DEFF Research Database (Denmark)

    2007-01-01

    The invention relates to a method and a system for synthesizing a set of controllable light beams by provision of a system for synthesizing a set of light beams, comprising a spatially modulated light source for generation of electromagnetic radiation with a set of replicas of a predetermined......(x-xs, y-ys), a Fourier transforming lens for Fourier transforming the electromagnetic radiation, a first spatial light modulator for phase shifting the Fourier transformed electromagnetic radiation with the phase -F(u, v) of S*, S* is the complex conjugate of the Fourier transformed symbol s, a Fourier...... transforming lens for Inverse Fourier transforming the spatially modulated radiation, whereby a set of light beams are formed propagating through the inverse Fourier plane (x', y') at desired positions (x's, y's), and a controller for controlling the position of a replica of the symbol, s, for movement...

  20. Beam Synchronous Timing Systems

    CERN Document Server

    Peters, A

    2003-01-01

    For many beam diagnostics purposes beam synchronous timing systems are needed in addition to the timing systems supplied by the control systems of the different accelerators. The demands and techniques of different accelerator facilities will be discussed along the following aspects: Bunch and macro pulse synchronous timing systems Solutions for different time scales from ps to ms Coupling to the RF and control systems of the different accelerators Electronics for the beam synchronous timing systems: parameters, techniques, controlling Use of industrial products for bunch synchronous timing systems, e.g. function generators Distribution of the timing signals: electronically via cables, optically via fibres or wireless Coupling to and use of timing standards: IRIG-B, GPS, ? The participants should present and describe solutions from their facilities with some transparencies as a starting point for the discussion.

  1. Beam characteristics of energy-matched flattening filter free beams

    Energy Technology Data Exchange (ETDEWEB)

    Paynter, D.; Weston, S. J.; Cosgrove, V. P. [St James Institute of Oncology The Leeds Teaching Hospitals NHS Trust, Medical Physics, Leeds LS9 7TF (United Kingdom); Evans, J. A. [LIGHT Institute University of Leeds Leeds LS2 9JT, Division of Medical Physics, Leeds (United Kingdom); Thwaites, D. I. [LIGHT Institute University of Leeds Leeds LS2 9JT, Division of Medical Physics, Leeds, United Kingdom and Institute of Medical Physics, School of Physics, University of Sydney (Australia)

    2014-05-15

    Purpose: Flattening filter free (FFF) linear accelerators can increase treatment efficiency and plan quality. There are multiple methods of defining a FFF beam. The Elekta control system supports tuning of the delivered FFF beam energy to enable matching of the percentage depth-dose (PDD) of the flattened beam at 10 cm depth. This is compared to FFF beams where the linac control parameters are identical to those for the flattened beam. All beams were delivered on an Elekta Synergy accelerator with an Agility multi-leaf collimator installed and compared to the standard, flattened beam. The aim of this study is to compare “matched” FFF beams to both “unmatched” FFF beams and flattened beams to determine the benefits of matching beams. Methods: For the three modes of operation 6 MV flattened, 6 MV matched FFF, 6 MV unmatched FFF, 10 MV flattened, 10 MV matched FFF, and 10 MV unmatched FFF beam profiles were obtained using a plotting tank and were measured in steps of 0.1 mm in the penumbral region. Beam penumbra was defined as the distance between the 80% and 20% of the normalized dose when the inflection points of the unflattened and flattened profiles were normalized with the central axis dose of the flattened field set as 100%. PDD data was obtained at field sizes ranging from 3 cm × 3 cm to 40 cm × 40 cm. Radiation protection measurements were additionally performed to determine the head leakage and environmental monitoring through the maze and primary barriers. Results: No significant change is made to the beam penumbra for FFF beams with and without PDD matching, the maximum change in penumbra for a 10 cm × 10 cm field was within the experimental error of the study. The changes in the profile shape with increasing field size are most significant for the matched FFF beam, and both FFF beams showed less profile shape variation with increasing depth when compared to flattened beams, due to consistency in beam energy spectra across the radiation field

  2. Optimal beam focusing through turbulence.

    Science.gov (United States)

    Charnotskii, Mikhail

    2015-11-01

    Beam spread and beam wandering are the most perceptible effects of atmospheric turbulence on propagating laser beams. The width of the mean irradiance profile is typically used to characterize the beam spread. This so-called long-term (LT) statistic allows for a relatively simple theoretical description. However, the LT beam size is not a very practical measure of the beam spread because its measurements are sensitive to the movements of the source and detector, and to the large-scale variations of the refractive index that are not associated with turbulence. The short-term (ST) beam spread is measured relative to the instantaneous position of the beam center and is free of these drawbacks, but has not been studied as thoroughly as the LT spread. We present a theoretical model for the ST beam irradiance that is based on the parabolic equation for the beam wave propagation in random media, and the Markov approximation for calculation of the statistics of the optical field, and discuss an approximation that allows introduction of the isoplanatic ST point spread function (PSF). Unlike the LT PSF, the ST PSF depends on the overall beam geometry. This allows optimization of the initial beam field in terms of minimizing the ST beam size at the observation plane. Calculations supporting this conjecture are presented for the simple case of the coherent Gaussian beam, and Kolmogorov turbulence.

  3. Active Beam Spectroscopy

    Science.gov (United States)

    von Hellermann, M. G.; Delabie, E.; Jaspers, R. J. E.; Biel, W.; Marchuk, O.; Summers, H. P.; Whiteford, A.; Giroud, C.; Hawkes, N. C.; Zastrow, K. D.

    2008-03-01

    Charge eXchange Recombination Spectroscopy (CXRS) plays a pivotal role in the diagnostics of hot fusion plasmas and is implemented currently in most of the operating devices. In the present report the main features of CXRS are summarized and supporting software packages encompassing "Spectral Analysis Code CXSFIT", "Charge Exchange Analysis Package CHEAP", and finally "Forward Prediction of Spectral Features" are described. Beam Emission Spectroscopy (BES) is proposed as indispensable cross-calibration tool for absolute local impurity density measurements and also for the continuous monitoring of the neutral beam power deposition profile. Finally, a full exploitation of the `Motional Stark Effect' pattern is proposed to deduce local pitch angles, total magnetic fields and possibly radial electric fields. For the proposed active beam spectroscopy diagnostic on ITER comprehensive performance studies have been carried out. Estimates of expected spectral signal-to-noise ratios are based on atomic modelling of neutral beam stopping and emissivities for CXRS, BES and background continuum radiation as well as extrapolations from present CXRS diagnostic systems on JET, Tore Supra, TEXTOR and ASDEX-UG. Supplementary to thermal features a further promising application of CXRS has been proposed recently for ITER, that is a study of slowing-down alpha particles in the energy range up to 2 MeV making use of the 100 keV/amu DNB (Diagnostic Neutral Beam) and the 500 keV/amu HNB (Heating Neutral Beam). Synthetic Fast Ion Slowing-Down spectra are evaluated in terms of source rates and slowing-down parameters

  4. A ciclovia da morte

    OpenAIRE

    Gois, Ancelmo

    2016-01-01

    De acordo com levantamento da FGV/DAPP, houve mais de 36 mil menções ao desabamento no Twi er, até o fim da tarde de ontem, com palavras como "vergonha", "incompetência" e "culpa" em destaque, além de muitas criticas ao prefeito Eduardo Paes.

  5. Dealing with megawatt beams

    Energy Technology Data Exchange (ETDEWEB)

    Mokhov, N.V.; /Fermilab

    2010-08-01

    The next generation of accelerators for MegaWatt proton, electron and heavy-ion beams puts unprecedented requirements on the accuracy of particle production predictions, the capability and reliability of the codes used in planning new accelerator facilities and experiments, the design of machine, target and collimation systems, detectors and radiation shielding and minimization of their impact on environment. Recent advances in code developments are described for the critical modules related to these challenges. Examples are given for the most demanding areas: targets, collimators, beam absorbers, radiation shielding, induced radioactivity and radiation damage.

  6. Quantized beam shifts

    CERN Document Server

    Kort-Kamp, W J M; Dalvit, D A R

    2015-01-01

    We predict quantized Imbert-Fedorov, Goos-H\\"anchen, and photonic spin Hall shifts for light beams impinging on a graphene-on-substrate system in an external magnetic field. In the quantum Hall regime the Imbert-Fedorov and photonic spin Hall shifts are quantized in integer multiples of the fine structure constant $\\alpha$, while the Goos- H\\"anchen ones in multiples of $\\alpha^2$. We investigate the influence on these shifts of magnetic field, temperature, and material dispersion and dissipation. An experimental demonstration of quantized beam shifts could be achieved at terahertz frequencies for moderate values of the magnetic field.

  7. Molecular beam epitaxy

    CERN Document Server

    Pamplin, Brian R

    1980-01-01

    Molecular Beam Epitaxy introduces the reader to the use of molecular beam epitaxy (MBE) in the generation of III-V and IV-VI compounds and alloys and describes the semiconductor and integrated optics reasons for using the technique. Topics covered include semiconductor superlattices by MBE; design considerations for MBE systems; periodic doping structure in gallium arsenide (GaAs); nonstoichiometry and carrier concentration control in MBE of compound semiconductors; and MBE techniques for IV-VI optoelectronic devices. The use of MBE to fabricate integrated optical devices and to study semicond

  8. Coherent laser beam combining

    CERN Document Server

    Brignon, Arnaud

    2013-01-01

    Recently, the improvement of diode pumping in solid state lasers and the development of double clad fiber lasers have allowed to maintain excellent laser beam quality with single mode fibers. However, the fiber output power if often limited below a power damage threshold. Coherent laser beam combining (CLBC) brings a solution to these limitations by identifying the most efficient architectures and allowing for excellent spectral and spatial quality. This knowledge will become critical for the design of the next generation high-power lasers and is of major interest to many industrial, environme

  9. Merged neutral beams

    Energy Technology Data Exchange (ETDEWEB)

    Osterwalder, Andreas [Ecole Polytechnique Federale de Lausanne (EPFL), Institute for Chemical Sciences and Engineering, Lausanne (Switzerland)

    2015-12-15

    A detailed description of a merged beam apparatus for the study of low energy molecular scattering is given. This review is intended to guide any scientist who plans to construct a similar experiment, and to provide some inspiration in describing the approach we chose to our goal. In our experiment a supersonic expansion of paramagnetic particles is merged with one of polar molecules. A magnetic and an electric multipole guide are used to bend the two beams onto the same axis. We here describe in detail how the apparatus is designed, characterised, and operated. (orig.)

  10. GTK beam test 2017

    CERN Document Server

    Vostinic, Snezana

    2017-01-01

    The GTK is in operation at NA62 since 2014 and is among the few silicon pixel detectors performing 4D tracking. This summer, a beam test was conducted to study the phenomena determining the detector time resolution. The project described here contributed to the beam test preparation, data taking and data analyses. One of the main goals of the test was to understand the weight field contribution to the detector time resolution. This field is distorting the signal pulse shape at the edge of the pixel. Hence, to study this effect, the position of the hits inside the pixel has to be determined. An external telescope was therefore used for this purpose.

  11. Comparative study between the PIXE technique and neutron activation analysis for Zinc determination; Estudo comparativo entre a tecnica de inducao de raios X por particulas e analise por ativacao com neutrons na determinacao do metal pesado zinco

    Energy Technology Data Exchange (ETDEWEB)

    Cruvinel, Paulo Estevao; Crestana, Silvio [Empresa Brasileira de Pesquisa Agropecuaria, Sao Carlos, SP (Brazil). CNPDIA. E-mail: cruvinel@cnpdia.embrapa.br; Armelin, Maria Jose Aguirre [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil); Artaxo Netto, Paulo Eduardo [Sao Paulo Univ., SP (Brazil). Inst. de Fisica

    1997-07-01

    This work presents a comparative study between the PIXE, proton beams and neutron activation analysis (NAA) techniques, for determination of total zinc concentration. Particularly, soil samples from the Pindorama, Instituto Agronomico de Campinas, Sao Paulo State, Brazil, experimental station have been analysed and measuring the zinc contents in {mu}g/g. The results presented good correlation between the mentioned techniques. The PIXE and NAA analyses have been carried out by using the series S, 2.4 MeV proton beams Pelletron accelerator and the IPEN/CNEN-IEA-R1 reactor, both installed at the Sao Paulo - Brazil university.

  12. Cartografia da paisagem alterada

    Directory of Open Access Journals (Sweden)

    Simone Cortezão

    2011-04-01

    Full Text Available O presente trabalho de pesquisa surge da investigação de paisagens alteradas, áreas pós-industriais e da geografia urbana que é conformada pela indústria. A preocupação principal é revê-las como espaço de investigação crítica sob o ponto de vista particular, integradas às noções da peculiar natureza industrial com suas consequentes transformações na paisagem, além das relações do indivíduo com esse novo meio produzido. “Cartografia da paisagem alterada” é uma pesquisa que indicia a paisagem alterada em pelo menos dois estratos: um que é o da construção da geografia da cidade pela indústria, e o outro que é a paisagem alterada subjetivamente, o que configura uma crítica e uma reação à conformação sócio geográfica em outros parâmetros - da proximidade, da experiência vivida e da construção de um vocabulário próprio.  A pesquisa teórica sobre áreas pós-industriais, associada a referências nas artes e arquitetura, constitui o primeiro estrato. Teorias e procedimentos artísticos de Robert Smithson, Joseph Beuys e Rem Koolhaas fornecem material para o segundo, mediante a pesquisa do cotidiano no lugar, a região do Vale do Aço, que se configura em um guia - glossário

  13. Effects of Transverse Beam Size in Beam Position Monitors

    CERN Document Server

    Kurennoy, S S

    2001-01-01

    The fields produced by a long beam with a given transverse charge distribution in a homogeneous vacuum chamber are studied. Signals induced by a displaced finite-size beam on electrodes of a beam position monitor (BPM) are calculated and compared to those produced by a pencil beam. The non-linearities and corrections to BPM signals due to a finite transverse beam size are calculated for an arbitrary chamber cross section. Simple analytical expressions are given for a few particular transverse distributions of the beam current in a circular or rectangular chamber. Of particular interest is a general proof that in an arbitrary homogeneous chamber the beam-size corrections vanish for any axisymmetric beam current distribution.

  14. Effects of transverse beam size in beam position monitors.

    Energy Technology Data Exchange (ETDEWEB)

    Kurennoy, S. (Sergey)

    2001-01-01

    The fields produced by a long beam with a given transverse charge distribution in a homogeneous vacuum chamber are studied. Signals induced by the displaced finite-size beam on electrodes of a beam position monitor (BPM) are calculated and compared to those from a pencil beam. The non-linearities and corrections to BPM signals due to a finite transverse beam size are calculated for an arbitrary chamber cross section. Simple analytical expressions are given for a few particular transverse distributions of the beam current in a circular or rectangular chamber. Of particular interest is a general proof that in an arbitrary homogeneous chamber the beam-size corrections vanish for any axisymmetric beam current distribution.

  15. EFFECTS OF TRANSFERSE BEAM SIZE IN BEAM POSITIONS MONITORS

    Energy Technology Data Exchange (ETDEWEB)

    S.S. KURENNOY

    2001-06-01

    The fields produced by a long beam with a given transverse charge distribution in a homogeneous vacuum chamber are studied. Signals induced by the displaced finite-size beam on electrodes of a beam position monitor (BPM) are calculated and compared to those from a pencil beam. The non-linearities and corrections to BPM signals due to a finite transverse beam size are calculated for an arbitrary chamber cross section. Simple analytical expressions are given for a few particular transverse distributions of the beam current in a circular or rectangular chamber. Of particular interest is a general proof that in an arbitrary homogeneous chamber the beam-size corrections vanish for any axisymmetric beam current distribution.

  16. Beam Loss and Beam Shape at the LHC Collimators

    CERN Document Server

    Burkart, Florian

    In this master thesis the beam loss and the beam shape at the LHC collimators was measured, analysed, presented and discussed. Beginning with a short introduction of the LHC, the experiments, the supercon- ducting magnet system, the basics on linear beam dynamics and a describtion of the LHC collimation system are given. This is followed by the presentation of the performance of the LHC collimation sys- tem during 2011. A method to convert the Beam Loss Monitor signal in Gy/s to a proton beam loss rate will be introduced. Also the beam lifetime during the proton physics runs in 2011 will be presented and discussed. Finally, the shape of the LHC beams is analysed by using data obtained by scraping the beam at the LHC primary collimators.

  17. Optimizing the electron beam parameters for head-on beam-beam compensation in RHIC

    Energy Technology Data Exchange (ETDEWEB)

    Luo, Y.; Fischer, W.; Pikin, A.; Gu, X.

    2011-03-28

    Head-on beam-beam compensation is adopted to compensate the large beam-beam tune spread from the protonproton interactions at IP6 and IP8 in the Relativistic Heavy Ion Collider (RHIC). Two e-lenses are being built and to be in stalled near IP10 in the end of 2011. In this article we perform numeric simulation to investigate the effect of the electron beam parameters on the proton dynamics. The electron beam parameters include its transverse profile, size, current, offset and random errors in them. In this article we studied the effect of the electron beam parameters on the proton dynamics. The electron beam parameters include its transverse shape, size, current, offset and their random errors. From the study, we require that the electron beam size can not be smaller than the proton beam's. And the random noise in the electron current should be better than 0.1%. The offset of electron beam w.r.t. the proton beam center is crucial to head-on beam-beam compensation. Its random errors should be below {+-}8{micro}m.

  18. Observed Orbit Effects during Long Range Beam-Beam Studies

    CERN Document Server

    Alemany, R; Buffat, X; Calaga, R; Fitterer, M; Giachino, R; Hemelsoet, GH; Herr, W; Papotti, G; Pieloni, T; Poyer, M; Schaumann, M; Trad, G; Wollmann, D

    2012-01-01

    Possible limitations due to long range beam-beam effects at the LHC have been studied and are presented in this note. With a larger number of bunches and collisions in all interaction points, the crossing angles were reduced to enhance long range beam-beam effects. The analysis of the effects on the dynamic aperture and losses are documented in [1]. This note concentrates on the bunch-by-bunch orbit effects observed during the experiment.

  19. Noncoaxial Bessel-Gauss beams.

    Science.gov (United States)

    Huang, Chaohong; Zheng, Yishu; Li, Hanqing

    2016-04-01

    We proposed a new family of noncoaxial Gauss-truncated Bessel beams through multiplying conventional symmetrical Bessel beams by a noncoaxial Gauss function. These beams can also be regarded as the exponential-truncated version of Bessel-Gauss beams since they can be transformed into the product of Bessel-Gauss beams and an exponential window function along a certain Cartesian axis. The closed-form solutions of the angular spectra and paraxial propagation of these beams were derived. These beams have asymmetrical intensity distributions and carry the same orbit angular momentum per photon as the corresponding Bessel-Gauss beams. While propagating along the z axis, the mth (m≠0) noncoaxial Bessel-Gauss beams rotate their intensity distributions and the mth-order vortex at the beam center has a transverse shift along the direction perpendicular to the offset axis. Depending on the product of the transverse scalar factor of the Bessel beams and the offset between the Gaussian window function and the center of the Bessel beams, the noncoaxial Bessel-Gauss beams can produce unit vortices with opposite signs in pairs during propagation.

  20. Longitudinal Beam Stability in the SUPER B-FACTORY

    Energy Technology Data Exchange (ETDEWEB)

    Novokhatski, A.; /SLAC; Zobov, M.; /Frascati

    2009-07-06

    We give an overview of wake fields and impedances in a proposed Super B project, which is based on extremely low emittance beams colliding at a large angle with a crab waist transformation. Understanding the effects that wake fields have on the beam is critical for a successful machine operation. We use our combined experience from the operation of the SLAC B-factory and DA{Phi}NE {Phi}-factory to eliminate strong HOM sources and minimize the chamber impedance in the Super B design. Based on a detailed study of the wake fields in this design we have developed a quasi-Green's function for the entire ring that is used to study bunch lengthening and beam stability. In particular, we check the stability threshold using numerical solutions of the Fokker-Plank equation. We also make a comparison of numerical simulations with the bunch lengthening data in the B- factory.

  1. Beam transport elements

    CERN Multimedia

    1965-01-01

    Two of the beam transport elements for the slow ejection system. On the left, a quadrupole 1.2 m long with a 5 cm aperture, capable of producing a gradient of 5000 gauss. On the right, a 1 m bending magnet with a 4 cm gap; its field is 20 000 gauss.

  2. Mode Gaussian beam tracing

    CERN Document Server

    Trofimov, M Yu; Kozitskiy, S B

    2015-01-01

    An adiabatic mode Helmholtz equation for 3D underwater sound propagation is developed. The Gaussian beam tracing in this case is constructed. The test calculations are carried out for the crosswedge benchmark and proved an excellent agreement with the source images method.

  3. Continuous Reinforced Concrete Beams

    DEFF Research Database (Denmark)

    Hoang, Cao Linh; Nielsen, Mogens Peter

    1996-01-01

    This report deals with stress and stiffness estimates of continuous reinforced concrete beams with different stiffnesses for negative and positive moments e.g. corresponding to different reinforcement areas in top and bottom. Such conditions are often met in practice.The moment distribution...

  4. Charged particle beams

    CERN Document Server

    Humphries, Stanley

    2013-01-01

    Detailed enough for a text and sufficiently comprehensive for a reference, this volume addresses topics vital to understanding high-power accelerators and high-brightness-charged particle beams. Subjects include stochastic cooling, high-brightness injectors, and the free electron laser. Humphries provides students with the critical skills necessary for the problem-solving insights unique to collective physics problems. 1990 edition.

  5. Ion-beam technologies

    Energy Technology Data Exchange (ETDEWEB)

    Fenske, G.R. [Argonne National Lab., IL (United States)

    1993-01-01

    This compilation of figures and diagrams reviews processes for depositing diamond/diamond-like carbon films. Processes addressed are chemical vapor deposition (HFCVD, PACVD, etc.), plasma vapor deposition (plasma sputtering, ion beam sputtering, evaporation, etc.), low-energy ion implantation, and hybrid processes (biased sputtering, IBAD, biased HFCVD, etc.). The tribological performance of coatings produced by different means is discussed.

  6. LHC Report: Beam on

    CERN Multimedia

    Rossano Giachino for the LHC Team

    2012-01-01

    The powering tests described in the last edition of the Bulletin were successfully finished at the end of the first week of March opening the way for 4 TeV operations this year. The beam was back in the machine on Wednesday 14 March. The first collisions at 4 TeV are scheduled for the first week of April.   The first beam of 2012 is dumped after making a few rounds in the LHC. The magnet powering tests were followed by the machine checkout phase. Here the operations team in collaboration with the equipment groups performs a sequence of tests to ensure the readiness of the LHC for beam. The tests include driving all the LHC systems – beam dump, injection, collimation, RF, power converters, magnet circuits, vacuum, interlocks, controls, timing and synchronization – through the operational cycle. The “checkout phase” is really a massive de-bugging exercise, which is performed with the objective of ensuring the proper functioning of the whole machine and t...

  7. Pulsed electron beam precharger

    Energy Technology Data Exchange (ETDEWEB)

    Finney, W.C. (ed.); Shelton, W.N.

    1991-01-01

    During the previous reporting period (Quarter Six), the charging and removal of a fine, high resistivity aerosol using the advanced technology of electron beam precipitation was successfully accomplished. Precharging a dust stream circulating through the EBP wind tunnel produced collection efficiency figures of up to 40 times greater than with corona charging and collection alone (Table 1). The increased system collection efficiency attributed to electron beam precharging was determined to be the result of increased particle charge. It was found that as precharger electric field was raised, collection efficiency became greater. In sequence, saturation particle charge varies with the precharger electric field strength, particle migration velocity varies with the precharger and collector electric field, and collection efficiency varies with the migration velocity. Maximizing the system collection efficiency requires both a high charging electric field (provided by the E-beam precharger), and a high collecting electric field (provided by the collector wires and plates). Because increased particle collection efficiency is directly attributable to higher particle charge, the focus of research during Quarter Seven was shifted to learning more about the actual charge magnitude on the aerosol particles. Charge determinations in precipitators have traditionally been made on bulk dust samples collected from the flue gas stream, which gives an overall charge vs. mass (Q/M) ratio measurement. More recently, techniques have been developed which allow the measurement of the charge on individual particles in a rapid and repeatable fashion. One such advanced technique has been developed at FSU for use in characterizing the electron beam precharger.

  8. BATMAN beam properties characterization by the beam emission spectroscopy diagnostic

    Science.gov (United States)

    Bonomo, F.; Ruf, B.; Barbisan, M.; Cristofaro, S.; Schiesko, L.; Fantz, U.; Franzen, P.; Pasqualotto, R.; Riedl, R.; Serianni, G.; Wünderlich, D.

    2015-04-01

    The ITER neutral beam heating systems are based on the production and acceleration of negative ions (H/D) up to 1 MV. The requirements for the beam properties are strict: a low core beam divergence (BATMAN (BAvarian Test MAchine for Negative ions) allows for deepening the knowledge of the determination of the beam properties. One of the diagnostics routinely used to this purpose is the Beam Emission Spectroscopy (BES): the Hα light emitted in the beam is detected and the corresponding spectra are evaluated to estimate the beam divergence and the stripping losses. The BES number of lines of sight in BATMAN has been recently increased: five horizontal lines of sight providing a vertical profile of the beam permit to characterize the negative ion beam properties in relation to the source parameters. Different methods of Hα spectra analysis are here taken into account and compared for the estimation of the beam divergence and the amount of stripping. In particular, to thoroughly study the effect of the space charge compensation on the beam divergence, an additional hydrogen injection line has been added in the tank, which allows for setting different background pressure values (one order of magnitude, from about 0.04 Pa up to the source pressure) in the beam drift region.

  9. Single Gradientless Light Beam Drags Particles as Tractor Beams

    DEFF Research Database (Denmark)

    Novitsky, Andrey; Qiu, Cheng-Wei; Wang, Haifeng

    2011-01-01

    is the strong nonparaxiality of the light beam, which contributes to the pulling force owing to momentum conservation. The nonparaxiality of the Bessel beam can be manipulated to possess a dragging force along both the radial longitudinal directions, i.e., a "tractor beam" with stable trajectories is achieved...

  10. Metal investigation of beams durable

    Directory of Open Access Journals (Sweden)

    Ya.A. Balabukh

    2011-12-01

    Full Text Available Results of metal researches of long-term storage beams are considered. It is determined that the steel of beams meets the requirements of Norms. Their acceptability for construction of bridges is established.

  11. Beam Injection in Recirculator SALO

    CERN Document Server

    Guk, Ivan S; Dovbnya, Anatoly N; Kononenko, Stanislav; Peev, Fedor; Tarasenko, Alexander; Van der Wiel, Marnix

    2005-01-01

    Possible antetypes of injectors for electron recirculator SALO,* intended for nuclear-physical research, are analyzed. The plan injection of beams in recirculator is offered. Expected parameters of beams are designed.

  12. Intense electron and ion beams

    CERN Document Server

    Molokovsky, Sergey Ivanovich

    2005-01-01

    Intense Ion and Electron Beams treats intense charged-particle beams used in vacuum tubes, particle beam technology and experimental installations such as free electron lasers and accelerators. It addresses, among other things, the physics and basic theory of intense charged-particle beams; computation and design of charged-particle guns and focusing systems; multiple-beam charged-particle systems; and experimental methods for investigating intense particle beams. The coverage is carefully balanced between the physics of intense charged-particle beams and the design of optical systems for their formation and focusing. It can be recommended to all scientists studying or applying vacuum electronics and charged-particle beam technology, including students, engineers and researchers.

  13. Depth-controlled Bessel beams

    CERN Document Server

    Müller, Angelina; Wallrabe, Ulrike

    2016-01-01

    We present a ring aperture with independently switchable segments for the three-dimensional control of quasi propagation invariant beams. We demonstrate that our liquid crystal design concept preserves coherence and generates the Bessel beam structure.

  14. Splash events First Beams 2008

    CERN Multimedia

    Collaboration, CMS

    2008-01-01

    First beam through the detector: images showing the debris, or "splash", of particles picked up in the detector's calorimeters and muon chambers after the beam was steered into the collimator (tungsten blocks) at Point 5.

  15. GERONTOLOGIA: ESTADO DA ARTE

    Directory of Open Access Journals (Sweden)

    Vera M.A.Tordino Brandão

    2010-02-01

    Full Text Available O Programa de Gerontologia da PUC desenvolve pesquisas focando o ser na perspectiva do envelhecimento. As atividades são interdisciplinares e reúnem docentes, alunos e ex-alunos. Nesta mesa redonda apresentamos um panorama sobre estes estudos. Na área da educação e comunicação o foco está centrado na longevidade e na preparação e representação social da velhice. São ressaltadas como temáticas: a formação continuada de profissionais e pesquisadores; o significado da religiosidade/espiritualidade ao longo da trajetória, e sua repercussão na qualidade de vida do idoso; os programas sócio-educacionais para idosos e concepções sobre educação; o monitoramento da mídia na cobertura da crescente longevidade e seus impactos. Em identidade e modos de morar reflete-se sobre soluções planejadas e sua adequação para a inclusão do envelhecimento populacional como questão fundamental, que implica a elaboração de novas políticas, investigações e, especialmente, apresenta-se como questão a ser analisada, refletida e vivenciada pela sociedade em geral. Quanto à saúde, o Programa desenvolve várias pesquisas numa abordagem interdisciplinar tendo como objetos de estudo: a terapia assistida com animais direcionada a idosos com diagnóstico de Alzheimer; o acompanhamento terapêutico e o atendimento psicoterapêutico em grupo, a aplicação da técnica de Calatonia em idosos moradores de ILPI, além da investigação sobre impasses clínicos no idoso frágil. Palavras-chave: gerontologia, longevidade, envelhecimento

  16. CONDICIONANTES DA COMPETITIVIDADE EMPRESARIAL

    Directory of Open Access Journals (Sweden)

    José Luiz Contador

    2010-03-01

    Full Text Available Este trabalho examina teoricamente os fatores determinantes da competitividade do produto e do negócio, imprescindíveis à elaboração de estratégias competitivas que visam à obtenção e sustentação de vantagens competitivas. Esse tema é objeto tanto da área de marketing estratégico quanto da de estratégia empresarial. Nas duas áreas, há um ponto de consenso que afirma que a empresa deve diferenciar sua oferta para conquistar e manter vantagem competitiva. Mas, os estudos conduzidos por meio do modelo de Campos e Armas da Competição revelaram que a empresa pode diferenciar seu produto e/ou serviço de modo mais amplo, levando em consideração, na formulação da sua estratégia competitiva, também o campo da competição, quer do produto, quer dela própria. Assim, o objetivo deste artigo é evidenciar que, para a empresa ser competitiva, além de diferenciar seu produto e/ou seu serviço no sentido tradicional, ela precisa: 1 diferenciar seu produto incluindo a definição em quais campos vai competir em cada segmento; e 2 escolher as armas da competição que irá utilizar e definir a intensidade de cada arma. Para atingir tal objetivo, foram necessários vários conceitos do modelo de Campos e Armas da Competição: campo da competição, arma da competição, tese do modelo, configuração dos campos da competição, campo coadjuvante, produto coadjuvante e par produto-mercado. Como uma proposta inovadora sempre desperta dúvida, é mostrado o processo de validação do modelo de Campos e Armas da Competição e são discutidas sua universalidade, consistência e completude.

  17. Damping modeling in Timoshenko beams

    Science.gov (United States)

    Banks, H. T.; Wang, Y.

    1992-01-01

    Theoretical and numerical results of damping model studies for composite material beams using the Timoshenko theory is presented. Based on the damping models developed for Euler-Bernoulli beams, the authors develop damping methods for both bending and shear in investigation of Timoshenko beams. A computational method for the estimation of the damping parameters is given. Experimental data with high-frequency excitation were used to test Timoshenko beam equations with different types of damping models for bending and shear in various combinations.

  18. Resolving two beams in beam splitters with a beam position monitor

    Energy Technology Data Exchange (ETDEWEB)

    Kurennoy, S. (Sergey)

    2002-01-01

    The beam transport system for the Advanced Hydrotest Facility (AHF) anticipates multiple beam splitters. Monitoring two separated beams in a common beam pipe in the splitter sections imposes certain requirements on diagnostics for these sections. In this note we explore a two-beam system in a generic beam monitor and study the feasibility of resolving the positions of the two beams with a single diagnostic device. In the Advanced Hydrotest Facility (AHF), 20-ns beam pulses (bunches) are extracted from the 50-GeV main proton synchrotron and then are transported to the target by an elaborated transport system. The beam transport system splits the beam bunches into equal parts in its splitting sections so that up to 12 synchronous beam pulses can be delivered to the target for the multi-axis proton radiography. Information about the transverse positions of the beams in the splitters, and possibly the bunch longitudinal profile, should be delivered by some diagnostic devices. Possible candidates are the circular wall current monitors in the circular pipes connecting the splitter elements, or the conventional stripline BPMs. In any case, we need some estimates on how well the transverse positions of the two beams can be resolved by these monitors.

  19. Study of beam-beam long range compensation with octupoles

    CERN Document Server

    Barranco Garcia, Javier; Buffat, Xavier; Tambasco, Claudia

    2017-01-01

    Long range beam-beam effects are responsible for particle losses and define fundamental operational parameters of colliders (i.e. crossing angles, intensities, emittances, ${\\beta}$${^∗}$). In this study we propose octuple magnets as a possible scheme to efficiently compensate long-range beam-beam interactions with a global correction scheme. The impact and improvements on the dynamic aperture of colliding beams together with estimates of the luminosity potentials are dis- cussed for the HL-LHC upgrade and extrapolations made for the FCC project.

  20. Cherenkov light-based beam profiling for ultrarelativistic electron beams

    Energy Technology Data Exchange (ETDEWEB)

    Adli, E., E-mail: Erik.Adli@fys.uio.no [Department of Physics, University of Oslo, N-0316 Oslo (Norway); SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025 (United States); Gessner, S.J.; Corde, S.; Hogan, M.J. [SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025 (United States); Bjerke, H.H. [SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025 (United States); Department of Physics, Norwegian University of Science and Technology, N-7491 Trondheim (Norway)

    2015-05-21

    We describe a beam profile monitor design based on Cherenkov light emitted from a charged particle beam in an air gap. The main components of the profile monitor are silicon wafers used to reflect Cherenkov light onto a camera lens system. The design allows for measuring large beam sizes, with large photon yield per beam charge and excellent signal linearity with beam charge. The profile monitor signal is independent of the particle energy for ultrarelativistic particles. Different design and parameter considerations are discussed. A Cherenkov light-based profile monitor has been installed at the FACET User Facility at SLAC. We report on the measured performance of this profile monitor.

  1. Flat profile laser beam shaper

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Todd R.

    2017-09-12

    A system for shaping a beam comprises an emitter for emitting coherent electromagnetic radiation. Birefringent displacers are configured between the emitter and a target wherein the at least two birefringent displacers split the coherent electromagnetic radiation into a plurality of coherent parallel beams of electromagnetic radiation thereby producing a shaped wave front of the coherent parallel beams of electromagnetic radiation.

  2. Focusing Electron Beams at SLAC.

    Science.gov (United States)

    Taylor, Richard L.

    1993-01-01

    Describes the development of a set of magnets that focus high-energy electron and positron beams causing them to collide, annihilate each other, and generate new particles. Explains how dipoles bend the beam, how quadrupoles focus the beam, how the focal length is calculated, and the superconducting final focus. (MDH)

  3. Spatial superpositions of Gaussian beams

    CSIR Research Space (South Africa)

    Naidoo, Darryl

    2014-02-01

    Full Text Available . At the plane of the lens we obtain a multi-ringed beam with a central intensity maximum which develops into a multi-ringed beam with a central null at the focal plane of the lens. The interesting feature of this beam is that it possesses two focal spots...

  4. Definition of Beam Diameter for Electron Beam Welding

    Energy Technology Data Exchange (ETDEWEB)

    Burgardt, Paul [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Pierce, Stanley W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dvornak, Matthew John [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-03-11

    It is useful to characterize the dimensions of the electron beam during process development for electron beam welding applications. Analysis of the behavior of electron beam welds is simplest when a single number can be assigned to the beam properties that describes the size of the beam spot; this value we generically call the “beam diameter”. This approach has worked well for most applications and electron beam welding machines with the weld dimensions (width and depth) correlating well with the beam diameter. However, in recent weld development for a refractory alloy, Ta-10W, welded with a low voltage electron beam machine (LVEB), it was found that the weld dimensions (weld penetration and weld width) did not correlate well with the beam diameter and especially with the experimentally determined sharp focus point. These data suggest that the presently used definition of beam diameter may not be optimal for all applications. The possible reasons for this discrepancy and a suggested possible alternative diameter definition is the subject of this paper.

  5. Beam-beam simulation code BBSIM for particle accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyung J.; Sen, Tanaji; /Fermilab

    2011-01-01

    A highly efficient, fully parallelized, six-dimensional tracking model for simulating interactions of colliding hadron beams in high energy ring colliders and simulating schemes for mitigating their effects is described. The model uses the weak-strong approximation for calculating the head-on interactions when the test beam has lower intensity than the other beam, a look-up table for the efficient calculation of long-range beam-beam forces, and a self-consistent Poisson solver when both beams have comparable intensities. A performance test of the model in a parallel environment is presented. The code is used to calculate beam emittance and beam loss in the Tevatron at Fermilab and compared with measurements. They also present results from the studies of stwo schemes proposed to compensate the beam-beam interactions: (a) the compensation of long-range interactions in the Relativistic Heavy Ion Collider (RHIC) at Brookhaven and the Large Hadron Collider (LHC) at CERN with a current carrying wire, (b) the use of a low energy electron beam to compensate the head-on interactions in RHIC.

  6. Beam-beam simulation code BBSIM for particle accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyung J.; Sen, Tanaji; /Fermilab

    2011-01-01

    A highly efficient, fully parallelized, six-dimensional tracking model for simulating interactions of colliding hadron beams in high energy ring colliders and simulating schemes for mitigating their effects is described. The model uses the weak-strong approximation for calculating the head-on interactions when the test beam has lower intensity than the other beam, a look-up table for the efficient calculation of long-range beam-beam forces, and a self-consistent Poisson solver when both beams have comparable intensities. A performance test of the model in a parallel environment is presented. The code is used to calculate beam emittance and beam loss in the Tevatron at Fermilab and compared with measurements. They also present results from the studies of stwo schemes proposed to compensate the beam-beam interactions: (a) the compensation of long-range interactions in the Relativistic Heavy Ion Collider (RHIC) at Brookhaven and the Large Hadron Collider (LHC) at CERN with a current carrying wire, (b) the use of a low energy electron beam to compensate the head-on interactions in RHIC.

  7. Perfect vortex beam: Fourier transformation of a Bessel beam.

    Science.gov (United States)

    Vaity, Pravin; Rusch, Leslie

    2015-02-15

    We derive a mathematical description of a perfect vortex beam as the Fourier transformation of a Bessel beam. Building on this development, we experimentally generate Bessel-Gauss beams of different orders and Fourier transform them to form perfect vortex beams. By controlling the radial wave vector of a Bessel-Gauss beam, we can control the ring radius of the generated beam. Our theoretical predictions match with the experimental results and also provide an explanation for previous published works. We find the perfect vortex resembles that of an orbital angular momentum (OAM) mode supported in annular profiled waveguides. Our prefect vortex beam generation method can be used to excite OAM modes in an annular core fiber.

  8. Metallic beam development for the Facility for Rare Isotope Beam

    Energy Technology Data Exchange (ETDEWEB)

    Machicoane, Guillaume, E-mail: machicoa@nscl.msu.edu; Cole, Dallas; Leitner, Daniela; Neben, Derek; Tobos, Larry [Facility for Rare Isotope Beam, Michigan State University, East Lansing, Michigan 48824 (United States)

    2014-02-15

    The Facility for Rare Isotope Beams (FRIB) at Michigan State University (MSU) will accelerate a primary ion beam to energies beyond 200 MeV/u using a superconducting RF linac and will reach a maximum beam power of 400 kW on the fragmentation target. The beam intensity needed from the ECR ion source is expected to be between 0.4 and 0.5 emA for most medium mass to heavy mass elements. Adding to the challenge of reaching the required intensity, an expanded list of primary beams of interest has been established based on the production rate and the number of isotope beams that could be produced with FRIB. We report here on the development done for some of the beam in the list including mercury (natural), molybdenum ({sup 98}Mo), and selenium ({sup 82}Ser)

  9. Het Italiaanse voorzetsel da

    NARCIS (Netherlands)

    Boer, M.G. de

    2010-01-01

    SAMENVATTING In een voorzetselstudie in het kader van Jackendoffs semantische theorie wordt het sterk polyseme Italiaanse voorzetsel da geanalyseerd als een verzameling deelbetekenissen waarbij de meeste door een of meer semantische regels afgeleid kunnen worden van de basisbetekenis ruimtelijke

  10. Het Italiaanse voorzetsel da

    NARCIS (Netherlands)

    Boer, M.G. de

    2010-01-01

    SAMENVATTING In een voorzetselstudie in het kader van Jackendoffs semantische theorie wordt het sterk polyseme Italiaanse voorzetsel da geanalyseerd als een verzameling deelbetekenissen waarbij de meeste door een of meer semantische regels afgeleid kunnen worden van de basisbetekenis ruimtelijke He

  11. ESPECTROS INFRAVERMELHOS DA CREATINA

    Directory of Open Access Journals (Sweden)

    Kumiko K. Sakane

    2011-08-01

    Full Text Available São apresentados espectros infravermelhos da creatina, na faixa de 4000 a 400 cm−1. Os resultados são comparados com espectros observados e calculados, publicados na literatura.

  12. Square shaped flat-top beam in refractive beam shapers

    Science.gov (United States)

    Laskin, Alexander; Laskin, Vadim; Ostrun, Aleksei

    2015-08-01

    Lossless transformation of round Gaussian to square shaped flat-top collimated beam is important in building highpower solid state laser systems to improve optical pumping or amplification. There are industrial micromachining applications like scribing, display repair, which performance is improved when a square shaped spot with uniform intensity is created. Proved beam shaping solutions to these techniques are refractive field mapping beam shapers having some important features: flatness of output phase front, small output divergence, high transmittance, extended depth of field, operation with TEM00 and multimode lasers. Usual approach to design refractive beam shapers implies that input and output beams have round cross-section, therefore the only way to create a square shaped output beam is using a square mask, which leads to essential losses. When an input laser beam is linearly polarized it is suggested to generate square shaped flat-top output by applying beam shaper lenses from birefringent materials or by using additional birefringent components. Due to birefringence there is introduced phase retardation in beam parts and is realized a square shaped interference pattern at the beam shaper output. Realization of this approach requires small phase retardation, therefore weak birefringence effect is enough and birefringent optical components, operating in convergent or divergent beams, can be made from refractive materials, which crystal optical axis is parallel to optical axis of entire beam shaper optical system. There will be considered design features of beam shapers creating square shaped flat-top beams. Examples of real implementations and experimental results will be presented as well.

  13. Impacto ambiental da apicultura

    OpenAIRE

    1999-01-01

    A cultura da abelha doméstica Apis. mellifera L. ou apicultura é conhecida desde a antiguidade, sendo o mel uni alimento natural corrente entre os povos primitivos. Pinturas rupestres mostram que desde o neolítico o homem era atraído pelo mel, pois tentava recolher ninhos de abelhas selvagens e instalava-os em cavidades naturais das rochas, muito perto da sua habitação.

  14. LEDA beam diagnostics instrumentation: Beam current measurement

    Science.gov (United States)

    Barr, D.; Day, L.; Gilpatrick, J. D.; Kasemir, K.-U.; Martinez, D.; Power, J. F.; Shurter, R.; Stettler, M.

    2000-11-01

    The Low Energy Demonstration Accelerator (LEDA) facility located at Los Alamos National Laboratory (LANL) accelerates protons to an energy of 6.7 MeV and current of 100 mA operating in either a pulsed or cw mode. Two types of current measurements are used. The first is an AC or pulsed-current measurement which uses three LANL built toroids. They are placed in the beamline in such a way as to measure important transmission parameters and act as a differential current-loss machine protection system. The second system is a DC current measurement used to measure cw beam characteristics and uses toroids from Bergoz Inc. There are two of these systems, so they can also be used for transmission measurements. The AC system uses custom processing electronics whereas the DC system uses a modified Bergoz® electronics system. Both systems feature data acquisition via a series of custom TMS320C40 Digital Signal Processing (DSP) boards. Of special interest to this paper is the operation of these systems, the calibration technique, the differential current loss measurements and fast-protection processing, current droop characteristics for the AC system, and existing system noise levels. This paper will also cover the DSP system operations and their interaction with the main accelerator control system.

  15. Neutrino beam plasma instability

    Indian Academy of Sciences (India)

    Vishnu M Bannur

    2001-10-01

    We derive relativistic fluid set of equations for neutrinos and electrons from relativistic Vlasov equations with Fermi weak interaction force. Using these fluid equations, we obtain a dispersion relation describing neutrino beam plasma instability, which is little different from normal dispersion relation of streaming instability. It contains new, nonelectromagnetic, neutrino-plasma (or electroweak) stable and unstable modes also. The growth of the instability is weak for the highly relativistic neutrino flux, but becomes stronger for weakly relativistic neutrino flux in the case of parameters appropriate to the early universe and supernova explosions. However, this mode is dominant only for the beam velocity greater than 0.25 and in the other limit electroweak unstable mode takes over.

  16. Slow light beam splitter.

    Science.gov (United States)

    Xiao, Yanhong; Klein, Mason; Hohensee, Michael; Jiang, Liang; Phillips, David F; Lukin, Mikhail D; Walsworth, Ronald L

    2008-07-25

    We demonstrate a slow light beam splitter using rapid coherence transport in a wall-coated atomic vapor cell. We show that particles undergoing random and undirected classical motion can mediate coherent interactions between two or more optical modes. Coherence, written into atoms via electromagnetically induced transparency using an input optical signal at one transverse position, spreads out via ballistic atomic motion, is preserved by an antirelaxation wall coating, and is then retrieved in outgoing slow light signals in both the input channel and a spatially-separated second channel. The splitting ratio between the two output channels can be tuned by adjusting the laser power. The slow light beam splitter may improve quantum repeater performance and be useful as an all-optical dynamically reconfigurable router.

  17. Silicon microfabricated beam expander

    Science.gov (United States)

    Othman, A.; Ibrahim, M. N.; Hamzah, I. H.; Sulaiman, A. A.; Ain, M. F.

    2015-03-01

    The feasibility design and development methods of silicon microfabricated beam expander are described. Silicon bulk micromachining fabrication technology is used in producing features of the structure. A high-precision complex 3-D shape of the expander can be formed by exploiting the predictable anisotropic wet etching characteristics of single-crystal silicon in aqueous Potassium-Hydroxide (KOH) solution. The beam-expander consist of two elements, a micromachined silicon reflector chamber and micro-Fresnel zone plate. The micro-Fresnel element is patterned using lithographic methods. The reflector chamber element has a depth of 40 µm, a diameter of 15 mm and gold-coated surfaces. The impact on the depth, diameter of the chamber and absorption for improved performance are discussed.

  18. Oberst beam test technique

    Science.gov (United States)

    Fasana, Alessandro; Garibaldi, Luigi; Giorcelli, Ermanno; Ruzzene, Massimo

    1998-06-01

    The definition of the mechanical properties of viscoelastic materials, i.e. the elastic modulus and the loss factor, is carried out, according to many national and international standards, with many different techniques, both of the resonant and non-resonant type. In this paper we focus our attention on the pros and cons of the resonant technique based on the classical Oberst beam method. When the damping material to be tested is not self-supporting, its properties are determined taking start from the measured modal frequencies and loss factors of a laminated beam, constituted by one or two metallic strips, ideally undamped, and one or two viscoelastic layers. The formulae specified on the standards hold valid under the assumptions of the theory developed by Kerwin, Ungar and Ross and we try in this paper to quantify witch deviation of the results should be expected when moving away from their ideal hypotheses.

  19. Silicon microfabricated beam expander

    Energy Technology Data Exchange (ETDEWEB)

    Othman, A., E-mail: aliman@ppinang.uitm.edu.my; Ibrahim, M. N.; Hamzah, I. H.; Sulaiman, A. A. [Faculty of Electrical Engineering, Universiti Teknologi MARA Malaysia, 40450, Shah Alam, Selangor (Malaysia); Ain, M. F. [School of Electrical and Electronic Engineering, Engineering Campus, Universiti Sains Malaysia, Seri Ampangan, 14300,Nibong Tebal, Pulau Pinang (Malaysia)

    2015-03-30

    The feasibility design and development methods of silicon microfabricated beam expander are described. Silicon bulk micromachining fabrication technology is used in producing features of the structure. A high-precision complex 3-D shape of the expander can be formed by exploiting the predictable anisotropic wet etching characteristics of single-crystal silicon in aqueous Potassium-Hydroxide (KOH) solution. The beam-expander consist of two elements, a micromachined silicon reflector chamber and micro-Fresnel zone plate. The micro-Fresnel element is patterned using lithographic methods. The reflector chamber element has a depth of 40 µm, a diameter of 15 mm and gold-coated surfaces. The impact on the depth, diameter of the chamber and absorption for improved performance are discussed.

  20. Neutrino beam line optics study

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Ming-Jen

    1996-09-01

    A study was done to understand the beam line optics from the beginning of Switchyard all the way to the end of Neutrino beam line. All available SWIC data were taken to get the beam centroid and width to be used in the analysis. The beam emittance and lattice function at the beginning of beam line can also be inferred from the study. The result indicated that the normalized 95% emittance to be around 15 {pi}-mm-mr for the vertical plane and about 28 {pi}-mm-mr for the horizontal plane.

  1. RIA Fragmentation Line Beam Dumps

    Energy Technology Data Exchange (ETDEWEB)

    Stein, W

    2003-08-08

    The Rare Isotope Accelerator project involves generating heavy-element ion beams for use in a fragmentation target line to produce beams for physics research. The main beam, after passing through the fragmentation target, may be dumped into a beam dump located in the vacuum cavity of the first dipole magnet. For a dump beam power of 100 kW, cooling is required to avoid excessive high temperatures. The proposed dump design involves rotating cylinders to spread out the energy deposition and turbulent subcooled water flow through internal water cooling passages to obtain high, nonboiling, cooling rates.

  2. Utilization of ALANPOL dosemeter composed by alanine and polyethylene for determination of doses in industrial effluents; Utilizacao do dosimetro ALANPOL composto por alanina e polietileno para determinacao de doses em efluentes industriais

    Energy Technology Data Exchange (ETDEWEB)

    Rela, Carolina S.; Sampa, Maria Helena de O.; Napolitano, Celia M. [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil)]. E-mail: csrela@ipen.br; Pontuschka, Walter M. [Sao Paulo Univ., SP (Brazil). Inst. de Fisica

    2005-07-01

    A study of traceability and accuracy was performed with the dosimetry system ALANPOL developed by IVHTJ/ Poland that uses alanine as a dosimeter and EPR as the read out system. The dosimeter ALANPOL is a polymer compound that aggregates alanine. The dosimeter has the outside diameter 3 mm, and the length of 25,4 mm (1 inch). In order to use this dosimeter for monitoring the existing real time calorimetry dosimeter system set up in a electron beam waste treatment plant. Electron beam and gamma irradiation experiments with ALANPOL was carried out under demineralized water and industrial effluent. The result show that in the dose range of 1-40 kGy the ALANPOL dosimeter system is suitable underwater monitoring for absorbed dose and can be applied for the evaluation of the on line calorimetry dosimeter system. (author)

  3. Characterization of radiation qualities used for the determination of characteristic in CT application according to IEC 61267:2005;Caracterizacao das qualidades de radiacao usadas na determinacao das caracteristicas em aplicacoes de CT de acordo com a IEC 61267: 2005

    Energy Technology Data Exchange (ETDEWEB)

    Dias, Daniel M.; Silva Junior, Iremar A. da; Potiens, Maria da Penha A. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2009-07-01

    The purpose of this study was to establish the standard RQT radiation qualities which represent simulations of the unattenuated beam used in Computed Tomography (CT). Thus, to avoiding excessive efforts for establishing a radiation quality by means of the spectral distribution of the photon fluence, the characterization of these standard radiation qualities was expressed in terms of the X-ray tube voltage, first and second half-value layer (HVL). To establishing the standard radiation beam, according to the IEC 61267 and the TRS 457 was measured first of all the correct values of the X ray tube voltages in terms of Practical Peak Voltage. The standard radiation qualities RQT were produced using the same set up mounted for the RQR qualities which had been early established, and for simulating the patient in order to achieve the standard RQT series, suitable thicknesses of layers of copper were used to obtain the values of the first HVL according to IEC 61267. (author)

  4. Beam-Material Interaction

    Energy Technology Data Exchange (ETDEWEB)

    Mokhov, N. V. [Fermilab; Cerutti, F. [CERN

    2016-01-01

    Th is paper is motivated by the growing importance of better understanding of the phenomena and consequences of high-intensity energetic particle beam interactions with accelerator, generic target, and detector components. It reviews the principal physical processes of fast-particle interactions with matter, effects in materials under irradiation, materials response, related to component lifetime and performance, simulation techniques, and methods of mitigating the impact of radiation on the components and environment in challenging current and future applications.

  5. Axion beams at HERA?

    OpenAIRE

    Piotrzkowski, Krzysztof

    2007-01-01

    If the recently observed anomaly in the PVLAS experiment is due to the axion, then the powerful beams of synchrotron photons, propagating through high magnetic field of the HERA beamline, become strong axion sources. This gives a unique opportunity of detection of the axion-photon interactions by installing a small detector in the HERA tunnel, and to corroborate the axion hypothesis within a few days of running. Comment: 5 pages, 1 figure

  6. Bidirectional beam propagation method

    Science.gov (United States)

    Kaczmarski, P.; Lagasse, P. E.

    1988-05-01

    A bidirectional extension of the beam propagation method (BPM) to optical waveguides with a longitudinal discontinuity is presented. The algorithm is verified by computing a reflection of the TE(0) mode from a semiconductor laser facet. The bidirectional BPM is applicable to other configurations such as totally reflecting waveguide mirrors, an abruption transition in a waveguide, or a waveguide with many discontinuities generating multiple reflections. The method can also be adapted to TM polarization.

  7. Magic Baseline Beta Beam

    CERN Document Server

    Agarwalla, Sanjib Kumar; Raychaudhuri, Amitava

    2007-01-01

    We study the physics reach of an experiment where neutrinos produced in a beta-beam facility at CERN are observed in a large magnetized iron calorimeter (ICAL) at the India-based Neutrino Observatory (INO). The CERN-INO distance is close to the so-called "magic" baseline which helps evade some of the parameter degeneracies and allows for a better measurement of the neutrino mass hierarchy and $\\theta_{13}$.

  8. Proton beam therapy facility

    Energy Technology Data Exchange (ETDEWEB)

    1984-10-09

    It is proposed to build a regional outpatient medical clinic at the Fermi National Accelerator Laboratory (Fermilab), Batavia, Illinois, to exploit the unique therapeutic characteristics of high energy proton beams. The Fermilab location for a proton therapy facility (PTF) is being chosen for reasons ranging from lower total construction and operating costs and the availability of sophisticated technical support to a location with good access to patients from the Chicago area and from the entire nation. 9 refs., 4 figs., 26 tabs.

  9. Mode Gaussian beam tracing

    Science.gov (United States)

    Trofimov, M. Yu.; Zakharenko, A. D.; Kozitskiy, S. B.

    2016-10-01

    A mode parabolic equation in the ray centered coordinates for 3D underwater sound propagation is developed. The Gaussian beam tracing in this case is constructed. The test calculations are carried out for the ASA wedge benchmark and proved an excellent agreement with the source images method in the case of cross-slope propagation. But in the cases of wave propagation at some angles to the cross-slope direction an account of mode interaction becomes necessary.

  10. Beam-Material Interaction

    CERN Document Server

    Mokhov, N.V.

    2016-01-01

    Th is paper is motivated by the growing importance of better understanding of the phenomena and consequences of high- intensity energetic particle beam interactions with accelerator, generic target , and detector components. It reviews the principal physical processes of fast-particle interactions with matter, effects in materials under irradiation, materials response, related to component lifetime and performance, simulation techniques, and methods of mitigating the impact of radiation on the components and envir onment in challenging current and future application

  11. Hyperon Beam Experiment

    CERN Multimedia

    2002-01-01

    The experiment WA89 uses the upgraded Omega facility together with a hyperon beam installed at the end of the H1 beamline. The beam can deliver 2~10$ ^{5} \\% Sigma ^- $ per machine burst at 330 GeV/c with a background of 5 10$ ^{5} \\% \\pi ^- $. \\\\ \\\\ The goals of the experiment are: observation of charmed particles, mainly the charmed-strange baryons and measurements of their production in the kinematical range x$ _{F} $~$>$~0.2, and their decay properties, a search for exotic states such as U(3100) observed in the previous CERN hyperon beam experiment WA62, measurements of hyperon polarization and production properties. \\\\ \\\\ A vertex detector consisting of 24 silicon microstrip planes with 25~$\\mu$m pitch and 6~planes with 50~$\\mu$m pitch provides track measurements of sufficient accuracy to identify the decays of short living charmed particles and measure their lifetimes. A RICH detector provides good $\\pi$/K separation for momenta up to 100~GeV/c and $\\pi$/p separation up to 150~GeV/c. Photons are detecte...

  12. Infrared Risley beam pointer

    Science.gov (United States)

    Harford, Steven T.; Gutierrez, Homero; Newman, Michael; Pierce, Robert; Quakenbush, Tim; Wallace, John; Bornstein, Michael

    2014-03-01

    Ball Aerospace & Technologies Corp. (BATC) has developed a Risley Beam Pointer (RBP) mechanism capable of agile slewing, accurate pointing and high bandwidth. The RBP is comprised of two wedged prisms that offer a wide Field of Regard (FOR) and may be manufactured and operated with diffraction limited optical quality. The tightly packaged mechanism is capable of steering a 4 inch beam over a 60° half angle cone with better than 60 μrad precision. Absolute accuracy of the beam steering is better than 1 mrad. The conformal nature of the RBP makes it an ideal mechanism for use on low altitude aircraft and unmanned aerial vehicles. Unique aspects of the opto-mechanical design include i) thermal compliance to maintain bearing preload and optical figure over a wide temperature range; and ii) packaging of a remote infrared sensor that periodically reports the temperature of both prisms for accurate determination of the index of refraction. The pointing control system operates each prism independently and employs an inner rate loop nested within an outer position loop. Mathematics for the transformation between line-of-sight coordinates and prism rotation are hosted on a 200 MHz microcontroller with just 516 KB of RAM.

  13. Neutron activation analysis for determining of inorganic trace elements in by-products of soybean, cotton, corn, wheat, sorghum and rice; Aplicacao da analise por ativacao com neutrons para determinacao de elementos inorganicos em subprodutos da soja, algodao, milho, trigo, sorgo e arroz

    Energy Technology Data Exchange (ETDEWEB)

    Teruya, Carla M.; Armelin, Maria Jose [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil); Silva Filho, Jose Cleto [Centro de Energia Nuclear na Agricultura (CENA), Piracicaba, SP (Brazil). Ciencias Animais; Silva, Aliomar G. [Empresa Brasileira de Pesquisa Agropecuaria (EMBRAPA), Sao Carlos, SP (Brazil). Centro de Pesquisa de Pecuaria do Sudeste

    1999-11-01

    In the present paper the instrumental neutron activation analysis was applied to determine some essential and toxic elements in six agroindustrial by-products utilized to feed animal. The accuracy of the method was evaluated by means of reference material analysis. In general, the precision of the method was lower than 10% and the accuracy near to 5%. (author) 7 refs., 1 tab.

  14. Use of LabSOCS for determination of specific concentrations of {sup 40}K, {sup 238}U and {sup 232}Th in fertilizer samples; Uso de LabSOCS no calculo da eficiencia de detecao para determinacao da concentracao especifica de {sup 40}K, {sup 238}U e {sup 232}Th em amostras de fertilizantes

    Energy Technology Data Exchange (ETDEWEB)

    Garcez, Ricardo Washington Dutra; Lopes, Jose Marques; Silva, Ademir Xavier da, E-mail: rgarcez@con.ufrj.br, E-mail: marqueslopez@yahoo.com.br [Coordenacao dos Programas de Pos-Graduacao em Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Nuclear; Domingues, Alessandro Mariano; Lima, Marco Frota, E-mail: slessandrodomingues@fisica.if.uff.br, E-mail: marcofrotalima@yahoo.com.br [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil). Instituto de Biologia

    2015-07-01

    Use of fertilizer is an established practice worldwide to promote agricultural productivity increased without increasing the planted area, resulting in native forests protection and increase of the food availability. Some kinds of fertilizer have in their chemical composition some radionuclides due the origin of its feedstock, such as {sup 238}U, the {sup 232}Th, and their descendants, beyond {sup 40}K. Knowledge of the radioactivity levels in the environment is great importance to know the gamma radiation dose that the human being is exposed. For identification and quantitation of radionuclides, it was used gamma spectrometry where HPGe detector was used to obtain the spectra, and LabSOCS software for calculating the detection efficiency for each energy. The values of {sup 232}Th specific concentrations ranged from 4.1 to 368.1 Bq.Kg{sup -1} , the values of {sup 238}U specific concentrations ranged from 16.0 to 647.7 Bq.Kg{sup -1} and {sup 40}K specific concentrations ranged from 19.1 to 12713 Bq.Kg{sup -1} . Concentrations of values are consistent with those found in literature. (author)

  15. Determination of As, Co, Cr and Fe on sediments and soil of the region of middle and low courses of the Rio da Velhas basin, MB, Brazil; Determinacao de As, Co, Cr e Fe em sedimentos e solo na regiao do medio e baixo curso da bacia do Rio das Velhas, Minas Gerais

    Energy Technology Data Exchange (ETDEWEB)

    Veado, Maria Adelaide R.V.; Trigueris, Giuliano de A.; Oliveira, Arno H. de; Carvalho, Fernando R. de [Minas Gerais Univ., Belo Horizonte, MG (Brazil). Dept. de Engenharia Nuclear]. E-mail: adelaide@nuclear.ufmg.br , heeren@nuclear.ufmg.br, fer@nuclear.ufmg.br; Veado, Julio Cesar C. [Minas Gerais Univ., Belo Horizonte, MG (Brazil). Escola de Veterinaria. Dept. de Clinica e Cirurgia Veterinarias]. E-mail: cambraia@vet.ufmg.br; Menezes, Maria Angela de B. C. [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN), Belo Horizonte, MG (Brazil). Supervisao de Reator e Radioanalise. Setor de Radioquimica]. E-mail: menezes@urano.cdtn.br

    2000-07-01

    The regions of the middle and low courses of the Rio das Velhas Basin are important under economical point of view for Minas Gerais State because of the agricultural production and high bovine population. In this work sediment and soil samples were analysed at monitoring points near the river established by FEAM-Fundacao Estadual do Meio Ambiente. As, Co, Cr and Fe were determined by means k{sub 0}-Neutron Activation Analysis. The sediment's and soil's results suggested metal contamination probably due to metals carried by high course water. (author)

  16. Contribution to the study of the determination of the remaining flow in deviation SHP (Small-Scale Hydroelectric Power Plants): the incorporation of the economic value of environmental resources; Contribuicao ao estudo da determinacao da vazao remanescente em PCHS (Pequenas Centrais Hidreletricas) de desvio: a incorporacao do valor economico de recursos ambientais

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Henrique Machado Moreira [Schlumberger, Itajuba, MG (Brazil)], e-mail: henriquemmsantos@yahoo.com.br; Santos, Afonso Henriques Moreira [Universidade Federal de Itajuba (UNIFEI/GEE/ISSE), MG (Brazil). Inst. de Sistemas Eletricos e Energia. Grupo de Estudos Energeticos], e-mail: afonsohms@gmail.com; Ribeiro Junior, Leopoldo Uberto, e-mail: leopoldo_junior@yahoo.com.br; Nascimento, Jose Guilherme Antloga do, e-mail: jgan@brasilpch.com.br

    2008-07-01

    This paper seems to develop the economic analysis of Small Hydro Plants - SHP, incorporating in this analysis evaluations of priceless losses for the society, as the environmental damages, taking SHP Paraitinga as the study case. It involves questions related to environmental valuation, economics, and engineering, presenting the concept of the Economic Valuation of Environmental Resources. The main valuation methods are presented. In the economic analysis, the concept of willingness to pay is verified by using demand function, that involves the elasticity and the price. The price is calculated based on costs and the elasticity is calculated based on the essentially of the goods or services, which could be reached by market observation. Only the remaining outflow definition, in the stretch of reduced outflow of the project will be studied. After these studies and valuations, some scenarios will be adopted for the developed model, on current values and projections. A comparison of the present work and the methodology of commitment programming are carried out. Finally the results will be analyzed, trying to get the 'optimum outflow', aiming at balancing power, tourism and environmental interests. (author)

  17. Determination of the frequency of polymorphisms in genes related to the genome stability maintenance of the population residing at Monte Alegre, PA (Brazil) municipality; Determinacao da frequencia de polimorfismos em genes relacionados a manutencao da estabilidade do genoma na populacao residente no municipio de Monte Alegre, PA

    Energy Technology Data Exchange (ETDEWEB)

    Hozumi, Cristiny Gomes

    2010-07-01

    The human exposure to ionizing radiation coming from natural sources is an inherent feature of human life on earth, for man and all living things have always been exposed to these sources. Ionizing radiation is a known genotoxic agent which can affect the genomic stability and genes related to DNA repair may play a role when they have committed certain polymorphism. This study aimed to analyze the frequency of polymorphisms (SNPs) in genes of DNA repair and cell cycle control: hOGG1 (Ser326Cys), XRCC3 (Thr241 Met) and p53 (Arg72Pro) in saliva samples from a population located Monte Alegre, state of Para were collected in August 2008 and 40 samples of men and 46 samples of women, adding a total of 86 samples. By RFLP was determined the frequency of homozygous genotypes and / or heterozygous for polymorphic genes. The I)OGG1 gene was 5% of the allele 326Cys, XRCC3 gene found about 21 % of the allele 241 Met and p53 gene showed 40.8% of the 72Pro allele. And the genotype frequencies of individuals for the three genes were 91.04%, 88.06% and 59.7% for homozygous wild genotype, 5.97%, 11.94% and 22.39% for heterozygote genotype and 2,99%, zero and 17:91% for homozygous polymorphic hOGG1 genes respectively, XRCC3, p53. These values are similar to those found in previous studies. The influence of these polymorphisms, which are involved in DNA repair and consequent genotoxicity induced by radiation depends on dose and exposure factors such as smoking, which is statistically a factor in public health surveillance in the region. This study gathered information and molecular epidemiology in Monte Alegre, that help to characterization of local population. (author)

  18. Validation of the extension of the range of application and of the single system of injection for the determination of total nitrogen in petroleum and its derivatives by chemiluminescence; Validacao da ampliacao da faixa de aplicacao e do sistema unico de injecao para a determinacao de nitrogenio total em petroleos e derivados por quimiluminescencia

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Maria de Fatima Pereira dos [Fundacao Gorceix, Ouro Preto, MG(Brazil)]. E-mail: santos@cenpes.petrobras.com.br; Tamanqueira, Juliana Boechat [Universidade Federal Fluminense, Niteroi, RJ (Brazil); Magalhaes, Julio Cesar Dias [PETROBRAS, Rio de Janeiro, RJ (Brazil). Centro de Pesquisas. Avaliacao de Petroleo; Oliveira, Elcio Cruz de [Transpetro, Rio de Janeiro, RJ (Brazil). Logistica e Planejamento; Vaitsman, Delmo Santiago [Universidade Federal, Rio de Janeiro, RJ (Brazil). Inst. de Quimica. Dept. de Quimica Analitica

    2003-12-01

    With the objectives of using a single system of injection and of extending the range of application for the method ASTM D4629/02 'Total Nitrogen in Petroleum Derivatives by the System of Injection with a Syringe and Detection by Chemo- Luminescence', it was studied a procedure by statistical validation with the objective of guaranteeing the analytical reliability of the assay and allowing the inclusion of samples of petroleum and heavy derivatives in one single methodology. The determination of total nitrogen for petroleum and derivatives is traditionally assayed using the method of Kjeldahl - a time-consuming methodology that requires a large amount of time for giving the final result, at the same time that is not recommended for concentrations below 0.1%w/w, which does not meet the requirements for the specifications of the product, in the petroleum industry. An alternative for the method of Kjeldahl is the pyro-chemo luminescence, which allows the achievement of more repetitive results for total nitrogen. In the detection of nitrogen, the technique combines the reliability of oxidative combustion with the sensitivity of chemiluminescence. Therefore, it was developed a protocol of validation in the methodology ASTM D4629/02 for the validation of the extension of the range of application and for the evaluation of the performance of the equipment in analytical conditions, according to the calibration curve. (author)

  19. Determination of migration speed and the partition ratios of {sup 137} Cs in the soils of the future waste repository in Abadia de Goias, GO, Brazil; Determinacao da velocidade de migracao e das razoes de particao de {sup 137} Cs em solos da regiao do futuro repositorio de rejeitos de Abadia de Goias, GO

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, Jose Carlos Alves

    1996-07-01

    The dispersion of a 51 TBq {sup 137} Cs source to the environment in Goiania city, has originated approximately 3500 m{sup 3} of radioactive waste. In order to segregate such waste in a definite form, a repository is being built in Abadia de Goias, GO near the site where it has been temporarily stored. This study had the following objectives: the determination of the {sup 137} Cs partition rate (K{sub D}) and the estimate of its migration velocity in soil samples from the site where the repository is being built. The determination of {sup 137} Cs K{sub D} was carried out by using two methods: 'batch method' and 'in-situ' method. In relation to the 'batch method'; 6 soil profiles cut into sections according to its pedologic horizons and 13 surface soil samples were collected, whereas for the 'in-situ' method 6 soil profiles with 28 cm depth were collected and each profile has been cut into 14 soil sections of a 1-3 cm range. Studies were carried out by using the 'batch method' to relate the influence from v/m and from shaking in K{sub D} determination and also studies about {sup 137} Cs adsorption reversibility in soil, time necessary for the equilibrium of {sup 137} Cs between water/soil phases to be reached and K{sub D} correlation with pedological parameters (pH values in water and clay, silt and organic material percent concentration, electrical conductivity of solution and the cation exchange - Ca{sup +2}, Mg {sup +2}, K{sup +2}, Na{sup +}, Al{sup +3}, H{sup +}). It has been noticed that in work conditions, K{sub D} has increased according to the rate increase v/m and the use of agitation in water/soil phases had no influence in K{sub D} determination. The absorbed {sup 137} Cs desorption process by water has shown to be slow but continued. Nevertheless, {sup 137} Cs cationic exchange for NH{sub 4}{sup +} has presented two steps: the first one very fast where approximately 50% of {sup 137} Cs adsorbed has been exchanged for NH{sub 4}{sup +} ions in just two days and the second one slow. Results indicate that {sup 137} Cs adsorption process in this kind of soil may be considered reversible. In using the 'batch method', it was noticed a higher {sup 137} Cs when increasing depth from soil profiles (108 - 897 cm{sup 3}.g{sup -1}). Nevertheless, {sup 137} Cs K{sub D} results point out to an average value of 430cm{sup 3}.g{sup -1}. This observation is confirmed when comparing to an average K{sub D} obtained by using 'batch method' and the K{sub D} value of 501 cm{sup 3}.g{sup -1} obtained by using 'in-situ' method. K{sub D} has just presented consistent linear correlation in relation to clay, [r=0,73]. Even though the type of clay found in the analyzed soils (caulinita) possess low adsorptive capacity, results have shown that as long as higher concentrations in clay in soil layers have been found, {sup 137} Cs K{sub D} has proportionally increased. Taking into consideration the hydrogeological medium conditions, {sup 137} Cs migration velocity found for a K{sub D} the average value obtained by using 'batch method' is 0,43 cm.year{sup -1}, whereas, for the 'in-situ' method was 0,37 cm.year{sup -1}. Assuming two meters as the minimum depth for ground water, {sup 137} Cs would take 460 - 500 years to reach it. (author)

  20. Relativistic electron beams above thunderclouds

    DEFF Research Database (Denmark)

    Füellekrug, M.; Roussel-Dupre, R.; Symbalisty, E. M. D.;

    2011-01-01

    Non-luminous relativistic electron beams above thunderclouds have been detected by the radio signals of low frequency similar to 40-400 kHz which they radiate. The electron beams occur similar to 2-9 ms after positive cloud-to-ground lightning discharges at heights between similar to 22-72 km above...... thunderclouds. Intense positive lightning discharges can also cause sprites which occur either above or prior to the electron beam. One electron beam was detected without any luminous sprite which suggests that electron beams may also occur independently of sprites. Numerical simulations show that beams...... of electrons partially discharge the lightning electric field above thunderclouds and thereby gain a mean energy of similar to 7MeV to transport a total charge of similar to-10mC upwards. The impulsive current similar to 3 x 10(-3) Am-2 associated with relativistic electron beams above thunderclouds...

  1. CLIC Drive Beam Phase Stabilisation

    CERN Document Server

    Gerbershagen, Alexander; Schulte, Daniel

    The thesis presents phase stability studies for the Compact Linear Collider (CLIC) and focuses in particular on CLIC Drive Beam longitudinal phase stabilisation. This topic constitutes one of the main feasibility challenges for CLIC construction and is an essential component of the current CLIC stabilisation campaign. The studies are divided into two large interrelated sections: the simulation studies for the CLIC Drive Beam stability, and measurements, data analysis and simulations of the CLIC Test Facility (CTF3) Drive Beam phase errors. A dedicated software tool has been developed for a step-by-step analysis of the error propagation through the CLIC Drive Beam. It uses realistic RF potential and beam loading amplitude functions for the Drive and Main Beam accelerating structures, complete models of the recombination scheme and compressor chicane as well as of further CLIC Drive Beam modules. The tool has been tested extensively and its functionality has been verified. The phase error propagation at CLIC h...

  2. Relativistic electron beams above thunderclouds

    Directory of Open Access Journals (Sweden)

    M. Füllekrug

    2011-05-01

    Full Text Available Non-luminous relativistic electron beams above thunderclouds are detected by radio remote sensing with low frequency radio signals from 40–400 kHz. The electron beams occur 2–9 ms after positive cloud-to-ground lightning discharges at heights between 22–72 km above thunderclouds. The positive lightning discharges also cause sprites which occur either above or before the electron beam. One electron beam was detected without any luminous sprite occurrence which suggests that electron beams may also occur independently. Numerical simulations show that the beamed electrons partially discharge the lightning electric field above thunderclouds and thereby gain a mean energy of 7 MeV to transport a total charge of 10 mC upwards. The impulsive current associated with relativistic electron beams above thunderclouds is directed downwards and needs to be considered as a novel element of the global atmospheric electric circuit.

  3. Premature beam dumps in 2011

    CERN Document Server

    Albert, Markus

    2012-01-01

    The statistical analysis of all non-programmed beam dumps during the 2011 proton run is presented. The selection criteria of fills that got considered were that the beam intensity of each of the two beams exceeded at least 1e12 particles per beam in order to exclude all probe beam dumps and most of the MPS test dumps. A distribution of beam dump causes by system is shown, as well as the time it took to re-establish injection after a non-programmed dump for fills which made it into STABLE BEAMS. This was done in an attempt to evaluate the cost of those non-programmed dumps in terms of time.

  4. Operational beams for the LHC

    CERN Document Server

    Papaphilippou, Y; Rumolo, G; Manglunki, D

    2014-01-01

    The variety of beams, needed to set-up in the injectors as requested in the LHC, are reviewed, in terms of priority but also performance expectations and reach during 2015. This includes the single bunch beams for machine commissioning and measurements (probe, Indiv) but also the standard physics beams with 50 ns and 25 ns bunch spacing and their high brightness variants using the Bunch Compression Merging and Splitting (BCMS) scheme. The required parameters and target performance of special beams like the doublet for electron cloud enhancement and the more exotic 8b$\\oplus$4e beam, compatible with some post-scrubbing scenarios are also described. The progress and plans for the LHC ion production beams during 2014-2015 are detailed. Highlights on the current progress of the setting up of the various beams are finally presented with special emphasis on potential performance issues across the proton and ion injector chain.

  5. Special Technologies Related to Electron Beam Welding

    Institute of Scientific and Technical Information of China (English)

    Zhao; Haiyan; Cai; Zhipeng; Wang; Xichang

    2007-01-01

    In order to improve the manufacturing quality of electron beam welding,some technologies are developed by using the special features of electron beam.Comparing with the conventional electron beam welding,the usage of multi-beam technology and micro-beam technology are introduced.In addition.the development of beam diagnostic system is also presented.

  6. Analysis of the additional filtration effects in X-ray beams from the calculation of average energy for photon in X-ray spectra; Analise dos efeitos da filtracao adicional em feixes de raios X a partir dos calculos de energia media por foton em espectros de raios X

    Energy Technology Data Exchange (ETDEWEB)

    Lucena, Rodrigo F.; Potiens, Maria da Penha A., E-mail: rodrigoifusp@yahoo.com.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-12-15

    The objective of this work was to analyze the behavior of X-ray spectra by calculating the average energy in each spectrum generated for different additional filtrations inserted in the X-ray beam. It was used an X-ray system present in the Laboratory of Instruments Calibration of the Instituto de Pesquisas Energeticas e Nucleares (IPEN) for the generation of X-ray beams, a spectrometry system with a solid state detector (semiconductor) to the data acquisition and aluminum and copper filters, with different thicknesses to be inserted in the output of the X-ray tube. The average energy per photon was calculated integrating the curve of each spectrum and dividing the value by the total number of counts. This calculation enabled to verify that the use of filtration in the X-ray equipment contributes significantly in the average energy of the X-ray beam. Thus, the same dose received by a patient or recorded by a detector has distinct average energies due to the use of filtrations with different materials and thicknesses, which allows the manipulation of X-ray beam through additional filtration. (author)

  7. BATMAN beam properties characterization by the beam emission spectroscopy diagnostic

    Energy Technology Data Exchange (ETDEWEB)

    Bonomo, F., E-mail: federica.bonomo@igi.cnr.it [Consorzio RFX (CNR, ENEA, INFN, Università di Padova, Acciaierie Venete SpA), Corso Stati Uniti 4, 35127 Padova (Italy); Istituto Gas Ionizzati - CNR, Corso Stati Uniti 4, 35127 Padova (Italy); Ruf, B.; Schiesko, L.; Fantz, U.; Franzen, P.; Riedl, R.; Wünderlich, D. [Max-Planck-Institut für Plasmaphysik, Boltzmannstr. 2, 85748 Garching (Germany); Barbisan, M.; Pasqualotto, R.; Serianni, G. [Consorzio RFX (CNR, ENEA, INFN, Università di Padova, Acciaierie Venete SpA), Corso Stati Uniti 4, 35127 Padova (Italy); Cristofaro, S. [Universitá degli Studi di Padova, Via 8 Febbraio 2, 35122 Padova (Italy)

    2015-04-08

    The ITER neutral beam heating systems are based on the production and acceleration of negative ions (H/D) up to 1 MV. The requirements for the beam properties are strict: a low core beam divergence (< 0.4 °) together with a low source pressure (≤ 0.3 Pa) would permit to reduce the ion losses along the beamline, keeping the stripping particle losses below 30%. However, the attainment of such beam properties is not straightforward. At IPP, the negative ion source testbed BATMAN (BAvarian Test MAchine for Negative ions) allows for deepening the knowledge of the determination of the beam properties. One of the diagnostics routinely used to this purpose is the Beam Emission Spectroscopy (BES): the H{sub α} light emitted in the beam is detected and the corresponding spectra are evaluated to estimate the beam divergence and the stripping losses. The BES number of lines of sight in BATMAN has been recently increased: five horizontal lines of sight providing a vertical profile of the beam permit to characterize the negative ion beam properties in relation to the source parameters. Different methods of H{sub α} spectra analysis are here taken into account and compared for the estimation of the beam divergence and the amount of stripping. In particular, to thoroughly study the effect of the space charge compensation on the beam divergence, an additional hydrogen injection line has been added in the tank, which allows for setting different background pressure values (one order of magnitude, from about 0.04 Pa up to the source pressure) in the beam drift region.

  8. Plasma-beam traps and radiofrequency quadrupole beam coolers.

    Science.gov (United States)

    Maggiore, M; Cavenago, M; Comunian, M; Chirulotto, F; Galatà, A; De Lazzari, M; Porcellato, A M; Roncolato, C; Stark, S; Caruso, A; Longhitano, A; Cavaliere, F; Maero, G; Paroli, B; Pozzoli, R; Romé, M

    2014-02-01

    Two linear trap devices for particle beam manipulation (including emittance reduction, cooling, control of instabilities, dust dynamics, and non-neutral plasmas) are here presented, namely, a radiofrequency quadrupole (RFQ) beam cooler and a compact Penning trap with a dust injector. Both beam dynamics studies by means of dedicated codes including the interaction of the ions with a buffer gas (up to 3 Pa pressure), and the electromagnetic design of the RFQ beam cooler are reported. The compact multipurpose Penning trap is aimed to the study of multispecies charged particle samples, primarily electron beams interacting with a background gas and/or a micrometric dust contaminant. Using a 0.9 T solenoid and an electrode stack where both static and RF electric fields can be applied, both beam transport and confinement operations will be available. The design of the apparatus is presented.

  9. Beam line design using G4BeamLine

    CERN Document Server

    Dogan, Arda

    2014-01-01

    In Turkey in Ankara TAEK SANAEM Proton Accelerator Facility (PAF), there is a cyclotron which produces a focused intense 30 MeV proton beam and sends this beam to four different arms, three of which uses this beam to produce pharmaceutical medicine. The remaining one is spared for R&D purposes and the idea was to use these protons coming out from the fourth arm to use space radiation tests, which cannot be done in Turkey at the moment. However, according to SCC 25100 standards which is for 30 MeV protons, the beam coming out of cyclotron is too intense and focused to use for space radiation tests. Therefore, the main aim of my project is to design a beam line which will defocus the beam and reduce the flux so that the space radiation tests can be done according to the standards of SCC 25100.

  10. Beam-Beam Effect with an External Noise in LHC

    CERN Document Server

    Ohmi, K; Höfle, Wolfgang; Tomás, R; Zimmermann, F

    2007-01-01

    In absence of synchrotron radiation, proton beams do not have any damping mechanism for incoherent betatron motion. A noise, which kicks beam particles in the transverse plane, gives a coherent betatron amplitude. If the system is linear, the coherent motion is maintained in amplitude. Nonlinear force, beam-beam and beam-electron cloud interactions, cause a decoherence of the betatron motion keeping the amplitude of each beam particle, with the result that an emittance growth arises. We focus only on fast noise with a correlation time of 1-100 turns. Slower noise is less serious, because it is regarded as an adiabatic change like a closed orbit change. As sources of the noise, we consider the bunch by bunch feedback system and phase jitter of cavities which turns to transverse noise via a crab cavity.

  11. LHC Beam Instrumentation: Beam Profile Measurements (2/3)

    CERN Document Server

    CERN. Geneva

    2014-01-01

    The LHC is equipped with a full suite of sophisticated beam instrumentation which has been essential for rapid commissioning, the safe increase in total stored beam power and the understanding of machine optics and accelerator physics phenomena. These lectures will introduce these systems and comment on their contributions to the various stages of beam operation. They will include details on: the beam position system and its use for real-time global orbit feedback; the beam loss system and its role in machine protection; total and bunch by bunch intensity measurements; tune measurement and feedback; diagnostics for transverse beam size measurements, abort gap monitoring and longitudinal density measurements. Issues and problems encountered along the way will also be discussed together with the prospect for future upgrades.

  12. Em defesa da semiodiversidade

    Directory of Open Access Journals (Sweden)

    Antônio Risério

    2008-11-01

    Full Text Available Semiodiversidade é um conceito que denomina a esfera da vida que se refere particularmente ao reino dos signos. Embora tenha sido criado no contexto das discussões sobre a biodiversidade, ele compreende um amplo campo que é quase desconhecido. Contrariamente à biodiversidade, não é um termo da moda, ainda que abarque um amploconjunto de problemas. As mais diferentes linguagens, signos e códigos culturais encontram lugar no domí­nio da semiodiversidade. Neste artigo a defesa da semiodiversidade é uma forma de preservar a vida humana neste momento da aventura do homem no planeta.Abstract: Semiodiversity is a concept to denominate the sphere of life that refers, particularly, to the realm of signs. Although it has been created in the context of biodiversity, it assigns a wider territory, which is almost unknown. Contrary to biodiversity, it is not a trendy' term, even though embeding a much wider scope. The most different languages, signs and cultural codes can be found in the domain of semiodiversity. In this article, the defense of semiodiversity is a way to preserve human life at this moment of humanadventure on Earth.

  13. Laser cooling of a stored ion beam: A first step towards crystalline beams

    Energy Technology Data Exchange (ETDEWEB)

    Hangst, J.S.

    1992-09-01

    This report discusses: a brief introduction to storage rings; crystalline beams; laser cooling of ion beams; description of astrid-the experimental setup; first experiments with lithium 7 ion beam; experiments with erbium 166 ion beams; further experiments with lithium 7 ion beams; beam dynamics, laser cooling,and crystalline beams in astrid; possibilities for further study in astrid.

  14. Micro-beam XRF localization by a laser beam

    Institute of Scientific and Technical Information of China (English)

    1999-01-01

    A new method for micro-beam XRF localization is presented. A laserbeam along with an incident X-ray hits on the surface of a sample. The micro region onthe sample that reached by X-ray beam can be localized by means of thevisible spot of the laser beam. This method is suitable for X-ray microprobesusing anX-ray tube or synchrotron radiation as excitation sources.

  15. Beam position monitor for energy recovered linac beams

    Energy Technology Data Exchange (ETDEWEB)

    Powers, Thomas; Evtushenko, Pavel

    2017-06-06

    A method of determining the beam position in an energy recovered linac (ERL). The method makes use of in phase and quadrature (I/Q) demodulation techniques to separate the pickup signal generated by the electromagnetic fields generated by the first and second pass beam in the energy recovered linac. The method includes using analog or digital based I/Q demodulation techniques in order to measure the relative amplitude of the signals from a position sensitive beam pickup such as a button, strip line or microstripline beam position monitor.

  16. Injection Beam Loss and Beam Quality Checks for the LHC

    CERN Document Server

    Kain, Verena; Bartmann, Wolfgang; Bracco, Chiara; Drosdal, Lene; Holzer, Eva; Khasbulatov, Denis; Magnin, Nicolas; Meddahi, Malika; Nordt, Annika; Sapinski, Mariusz; Vogt, Mathias

    2010-01-01

    The quality of the injection into the LHC is monitored by a dedicated software system which acquires and analyses the pulse waveforms from the injection kickers, and measures key beam parameters and compares them with the nominal ones. The beam losses at injection are monitored on many critical devices in the injection regions, together with the longitudinal filling pattern and maximum trajectory offset on the first 100 turns. The paper describes the injection quality check system and the results from LHC beam commissioning, in particular the beam losses measured during injection at the various aperture limits. The results are extrapolated to full intensity and the consequences are discussed

  17. Continuous Reinforced Concrete Beams

    DEFF Research Database (Denmark)

    Hoang, Cao Linh; Nielsen, Mogens Peter

    1996-01-01

    This report deals with stress and stiffness estimates of continuous reinforced concrete beams with different stiffnesses for negative and positive moments e.g. corresponding to different reinforcement areas in top and bottom. Such conditions are often met in practice.The moment distribution...... at the limit state of serviceability is in some simple cases determined by setting up the statical and the compatibility conditions.With these moment distributions, the maximum deflection and the reinforcement stresses at the span middle and at a support are calculated.The results are compared with results...

  18. Beam Instrument Development System

    Energy Technology Data Exchange (ETDEWEB)

    2016-01-08

    Beam Instrumentation Development System (BIDS) is a collection of common support libraries and modules developed during a series of Low-Level Radio Frequency (LLRF) control and timing/synchronization projects. BIDS includes a collection of Hardware Description Language (HDL) libraries and software libraries. The BIDS can be used for the development of any FPGA-based system, such as LLRF controllers. HDL code in this library is generic and supports common Digital Signal Processing (DSP) functions, FPGA-specific drivers (high-speed serial link wrappers, clock generation, etc.), ADC/DAC drivers, Ethernet MAC implementation, etc.

  19. da etiologia ao tratamento

    OpenAIRE

    Soares, Tânia Alexandra Maia

    2013-01-01

    Projeto de Pós-Graduação/Dissertação apresentado à Universidade Fernando Pessoa como parte dos requisitos para obtenção do grau de Mestre em Medicina Dentária A luxação da articulação temporomandibular (ATM) ocorre quando o côndilo mandibular se desloca para fora da fossa mandibular e não é capaz de retornar. As manifestações clinicas mais frequentes desta patologia são: dificuldade de fechar a boca, depressão pré-auricular, sialorréia, tensão dos músculos da mastigação e dor severa na reg...

  20. Fundamentos da psicologia social

    OpenAIRE

    Kruger, Helmuth Ricardo

    1984-01-01

    O tema central deste estudo é o dos fundamentos da Psicologia Social. Neste sentido, foram examinados pressupostos ontológicos, epistemológicos, lógicos e axiológicos mas, também, as bases conceituais, teóricas e metodológicas deste setor da Psicologia contemporânea. A justificar este empreendimento, encontram-se duas suposições: a de que qualquer ciência é inexoravelmente construída sobre postulados metafísicos e lógicos, e a de que a falta de clareza em relação a estes impede a instalação d...

  1. DA LITERATURA AO PENSAMENTO

    Directory of Open Access Journals (Sweden)

    Gustavo Bernardo

    2012-07-01

    Full Text Available Apresento uma concepção pessoal do ensino de literatura, condensando a discussão das principais questões que o afetam: a singularidade da disciplina entre as demais disciplinas escolares; a crítica do realismo como valor dominante; a importância do exemplo; os efeitos da desvalorização salarial e moral do professor; a praga das adaptações literárias para jovens. A partir dessas questões, apresento cinco modos de leitura e ensino do texto literário, a saber: ler como resposta; ler como pergunta; a leitura ingênua; a leitura crítica; a leitura teórica. Concluo pela necessidade de proteção radical à dúvida, fundadora da literatura e do próprio pensamento.

  2. Controlling Beam Halo-Chaos

    Institute of Scientific and Technical Information of China (English)

    方锦清; 罗晓曙; 陈关荣; 翁甲强

    2001-01-01

    Beam halo-chaos is essentially a complex spatiotemporal chaotic motion in a periodic-focusing channel of a highpower linear proton accelerator. The controllability condition for beam halo-chaos is analysed qualitatively. A special nonlinear control method, i.e. the wavelet-based function feedback, is proposed for controlling beam halochaos. Particle-in-cell simulations are used to explore the nature of halo-chaos formation, which has shown that the beam hMo-chaos is suppressed effectively after using nonlinear control for the proton beam with an initial full Gaussian distribution. The halo intensity factor Hav is reduced from 14%o to zero, and the other statistical physical quantities of beam halo-chaos are more than doubly reduced. The potential applications of such nonlinear control in experiments are briefly pointed out.

  3. Self accelerating electron Airy beams

    CERN Document Server

    Voloch-Bloch, Noa; Lilach, Yigal; Gover, Avraham; Arie, Ady

    2013-01-01

    We report the first experimental generation and observation of Airy beams of free electrons. The electron Airy beams are generated by diffraction of electrons through a nanoscale hologram, that imprints a cubic phase modulation on the beams' transverse plane. We observed the spatial evolution dynamics of an arc-shaped, self accelerating and shape preserving electron Airy beams. We directly observed the ability of electrons to self-heal, restoring their original shape after passing an obstacle. This electromagnetic method opens up new avenues for steering electrons, like their photonic counterparts, since their wave packets can be imprinted with arbitrary shapes or trajectories. Furthermore, these beams can be easily manipulated using magnetic or electric potentials. It is also possible to efficiently self mix narrow beams having opposite signs of acceleration, hence obtaining a new type of electron interferometer.

  4. Beam Position Monitoring at CLIC

    CERN Document Server

    Prochnow, J

    2003-01-01

    At the European Organisation for Nuclear Research CERN in Geneva, Switzerland the design of the Compact LInear Collider (CLIC) for high energy physics is studied. To achieve the envisaged high luminosity the quadrupole magnets and radio-frequency accelerating structures have to be actively aligned with micron precision and submicron resolution. This will be done using beam-based algorithms which rely on beam position information inside of quadrupoles and accelerating structures. After a general introduction to the CLIC study and the alignment algorithms, the concept of the interaction between beams and radio-frequency structures is given. In the next chapter beam measurements and simulations are described which were done to study the performance of cavity beam position monitors (BPM). A BPM design is presented which is compatible with the multi-bunch operation at CLIC and could be used to align the quadrupoles. The beam position inside the accelerating structures will be measured by using the structures thems...

  5. Edge effect in beam monitors

    CERN Document Server

    Cuperus, J H

    1977-01-01

    Quite often, particle-beam monitors have not the same cross-section as the beam pipe or vacuum chamber in which they are mounted. In that case, the electromagnetic field of the beam is distorted in the vicinity of the edges of the monitor. This field, at the junction of two rectangular beam pipes of different dimensions, is computed for a beam with constant charge along its length. Solutions which are less accurate but easier to apply are obtained with a first order approximation. The results are extended to intensity-modulated beams and circular or elliptical cross-sections. The errors, due to the edge effect, for the electrostatic pickup and the wall-current monitor are computed. The final formulas are simple and easy to apply to practical cases. (6 refs).

  6. CLIC Drive Beam Position Monitor

    CERN Document Server

    Smith, S; Gudkov, D; Soby, L; Syratchev, I

    2011-01-01

    CLIC, an electron-positron linear collider proposed to probe the TeV energy scale, is based on a two-beam scheme where RF power to accelerate a high energy luminosity beam is extracted from a high current drive beam. The drive beam is efficiently generated in a long train at modest frequency and current then compressed in length and multiplied in frequency via bunch interleaving. The drive beam decelerator requires >40000 quadrupoles, each holding a beam position monitor (BPM). Though resolution requirements are modest (2 microns) these BPMs face several challenges. They must be compact and inexpensive. They must operate below waveguide cutoff to insure locality of position signals, ruling out processing at the natural 12 GHz bunch spacing frequency. Wakefields must be kept low. We find compact conventional stripline BPM with signals processed below 40 MHz can meet requirements. Choices of mechanical design, operating frequency, bandwidth, calibration and processing algorithm are presented. Calculations of wa...

  7. Medidas de rentabilidade da empresa

    OpenAIRE

    Mota, Haroldo Moura Vale

    2010-01-01

    Faz uma avaliação da medida de retorno contábil da corporação (return on investment - ROI) à luz da verdadeira medida de retorno econômico (taxa interna de retorno - TIR). Apresenta modelo para cálculo da taxa interna de retorno da empresa, o qual é submetido à testes para aferir o seu valor informativo. Utilizando o conceito de taxa interna de retorno da corporação, é criado um modelo denominado de Modelo de Avaliação Econômica Base Caixa, aplicável a uma empresa b...

  8. Beam simulation studies of ECR beam extraction and low energy beam transport for FRIB.

    Science.gov (United States)

    Ren, Haitao; Pozdeyev, Eduard; Lund, Steven M; Machicoane, Guillaume; Wu, Xiaoyu; Morgan, Glenn

    2016-02-01

    To meet the beam power requirements of 400 kW at the fragmentation target for facility for Rare Isotope Beams (FRIB), simultaneous acceleration of two-charge states should be used for heavier ions. These intense multi-charged ion beams will be produced by a 28 GHz electron cyclotron resonance (ECR) ion source at a high voltage of 35 kV. After extraction, the ion beam will be pre-accelerated to 12 keV/u with a 50 kV platform, transported down to an achromatic charge state selection (CSS) system followed by a vertical transport line, and then injected into a radio frequency quadrupole accelerator. The TRACK code developed at ANL is used to perform the simulations of the ECR beam extraction and low energy beam transport for FRIB. In this study, we include the magnetic field of ECR ion source into simulations. Different initial beam conditions as well as different space charge neutralization levels are tested for the ECR beamline. The beam loss in CSS system and the corresponding protective measures are discussed. The detailed results about the beam dynamic simulation and beam loss in CSS system will be presented in this paper.

  9. Simulation of beam-induced plasma for the mitigation of beam-beam effects

    Energy Technology Data Exchange (ETDEWEB)

    Ma, J.; Wang, G.; Samulyak, R.; Yu, K.; Litvinenko, V.

    2015-05-03

    One of the main challenges in the increase of luminosity of circular colliders is the control of the beam-beam effect. In the process of exploring beam-beam mitigation methods using plasma, we evaluated the possibility of plasma generation via ionization of neutral gas by proton beams, and performed highly resolved simulations of the beam-plasma interaction using SPACE, a 3D electromagnetic particle-in-cell code. The process of plasma generation is modelled using experimentally measured cross-section coefficients and a plasma recombination model that takes into account the presence of neutral gas and beam-induced electromagnetic fields. Numerically simulated plasma oscillations are consistent with theoretical analysis. In the beam-plasma interaction process, high-density neutral gas reduces the mean free path of plasma electrons and their acceleration. A numerical model for the drift speed as a limit of plasma electron velocity was developed. Simulations demonstrate a significant reduction of the beam electric field in the presence of plasma. Preliminary simulations using fully-ionized plasma have also been performed and compared with the case of beam-induced plasma.

  10. Attenuation study of 6MV beam in post-mastectomy breast radiotherapy due to metallic heterogeneity of tissue expanders; Estudo da atenuacao do feixe de 6MV em tratamentos radioterapicos de mama pos-mastectomia devido a heterogeneidade metalica de expansores de tecido

    Energy Technology Data Exchange (ETDEWEB)

    Trombetta, Debora M.; Silva, Ademir X. da, E-mail: dtrombetta@con.ufrj.b [Universidade Federal do Rio de Janeiro (PEN/COPPE/UFRJ), RJ (Brazil). Coordenacao dos Programas de Pos-Graduacao de Engenharia. Programa de Energia Nuclear; Cardoso, Simone C. [Universidade Federal do Rio de Janeiro (IF/UFRJ), RJ (Brazil). Inst. de Fisica; Facure, Alessandro [Comissao Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil); Rosa, Luiz A.R. da [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2010-06-15

    In this work, the effects produced in attenuation of 6 MV radiotherapic beam as consequence of metallic heterogeneities present in some types of tissue expanders, used in the process of mammary reconstruction, were studied. The study was developed through the quantification relative transmission making use of computer simulations with Monte Carlo method, using the code MCNPX. The results showed that the presence of this metallic heterogeneity alters the transmission of the beam, causing a reduction up to 20% in the geometric shadowed region. According to dosimetry protocols, the reduction in the dose should be lower of 5%. Therefore the difference found in the study could be relevant to consider the presence of heterogeneity in the irradiation field for the treatment planning. (author)

  11. Da Vinci Linjen

    DEFF Research Database (Denmark)

    Nissen, Poul

    Afsluttende evalueringsrapport fra følgeforskningen gennem tre år i forbindelse med dety pædagogiske arbejde på Blåbjerggårdskolens Da Vinci Linje for skolemotiverede og underpræsterende elever på 7. til 9. klassetrin.......Afsluttende evalueringsrapport fra følgeforskningen gennem tre år i forbindelse med dety pædagogiske arbejde på Blåbjerggårdskolens Da Vinci Linje for skolemotiverede og underpræsterende elever på 7. til 9. klassetrin....

  12. GESTAO DA AGRICULTURA URBANA

    OpenAIRE

    2014-01-01

    Este artigo apresenta o conceito de agricultura urbana e sua contribuição para a integração da atividade agrícola com o ambiente urbano, incentivando o desenvolvimento de cidades sustentáveis. Analisa o grau de complexidade encontrado pelas autoridades ao criar e aplicar politicas pública onde os sistemas urbanos de suprimento de alimentos não são acessíveis a toda a população. Traz luz a algumas das questões diretamente relacionadas à implantação da agricultura em grandes centros urbanos, ta...

  13. Beam emittance measurements at Fermilab

    Energy Technology Data Exchange (ETDEWEB)

    Wendt, Manfred; Eddy, Nathan; Hu, Martin; Scarpine, Victor; Syphers, Mike; Tassotto, Gianni; Thurman-Keup, Randy; Yang, Ming-Jen; Zagel, James; /Fermilab

    2008-01-01

    We give short overview of various beam emittance measurement methods, currently applied at different machine locations for the Run II collider physics program at Fermilab. All these methods are based on beam profile measurements, and we give some examples of the related instrumentation techniques. At the end we introduce a multi-megawatt proton source project, currently under investigation at Fermilab, with respect to the beam instrumentation challenges.

  14. Harmonic vibrations of multispan beams

    DEFF Research Database (Denmark)

    Dyrbye, Claes

    1996-01-01

    Free and forced harmonic vibrations of multispan beams are determined by a method which implies 1 equation regardless of the configuration. The necessary formulas are given in the paper. For beams with simple supports and the same length of all (n) spans, there is a rather big difference between...... the n´th and the (n+1)´th eigenfrequency. The reason for this phenomenon is explained.Keywords: Vibrations, Eigenfrequencies, Beams....

  15. Atomic laser-beam finder.

    Science.gov (United States)

    Viering, Kirsten; Medellin, David; Mo, Jianyong; Raizen, Mark G

    2012-11-05

    We report on an experimental method to align a laser beam to a cloud of atoms trapped in a magneto-optical trap (MOT). We show how balanced lock-in detection leads to a very sensitive method to align the laser beam to the atoms in the plane perpendicular to the propagation direction. This provides a very reliable and fast way of aligning laser beams to atoms trapped in a MOT.

  16. First Beam Splash Events 2008

    CERN Multimedia

    Collaboration, CMS

    2008-01-01

    10th September 2008 at 10.00 a.m. CMS saw the beam pass through the experiment for the first time ever, in the clockwise direction. The beam was initially intentionally stopped by blocks around 154 metres before CMS at Point 5, producing these images of the debris or "splash" from the particles hitting the blocks. After removal of the blocks, the beam then passed through CMS successfully. At 14.30 beam then passed successfully in the anticlockwise direction through the experiment.

  17. Terahertz beam shaping with metasurface

    Science.gov (United States)

    He, Jingwen; Wang, Sen; Zhang, Yan

    2016-11-01

    Based on metasurface, two beam shapers are designed to modulate the wavefront of the terahertz beam. One of the beam shapers is THz ring-Airy beam generator and the other is THz four-focus lens. Each beam shaper is composed of a serious of C-shaped slot antennas, which can be used to modulate the phase and amplitude of the cross-polarized scattered wave. A THz holographic imaging system is utilized to measure the field of the generated beams. The ring- Airy beam shaper is designed by replacing both the phase and amplitude of its initial electric field with the corresponding antennas. In the experiment, an abrupt focus following a parabolic trajectory is subsequently observed. This method can be expanded to other wavebands, such as the visible band, in which the ring-Airy beam shaper can replace traditional computer-generated holography to avoid undesirable multiple diffraction orders. The phase distribution of the four-focus lens is obtained by using the Yang-Gu amplitude-phase retrieval algorithm and then encoded to the antennas. Both the focusing and imaging properties are demonstrated. A clear image can be obtained with a bandwidth of 110 GHz. This type of transmissive metasurface beam shaper serves as an attractive alternative to conventional diffractive optical elements based on its small size, ease of fabrication, and low cost.

  18. Compact electron beam focusing column

    Energy Technology Data Exchange (ETDEWEB)

    Persaud, Arun; Leung, Ka-Ngo; Reijonen, Jani

    2001-07-13

    A novel design for an electron beam focusing column has been developed at LBNL. The design is based on a low-energy spread multicusp plasma source which is used as a cathode for electron beam production. The focusing column is 10 mm in length. The electron beam is focused by means of electrostatic fields. The column is designed for a maximum voltage of 50 kV. Simulations of the electron trajectories have been performed by using the 2-D simulation code IGUN and EGUN. The electron temperature has also been incorporated into the simulations. The electron beam simulations, column design and fabrication will be discussed in this presentation.

  19. Beam shifts and distribution functions

    CERN Document Server

    Aiello, Andrea

    2011-01-01

    When a beam of light is reflected by a smooth surface its behavior deviates from geometrical optics predictions. Such deviations are quantified by the so-called spatial and angular Goos-Haenchen (GH) and Imbert-Fedorov (IF) shifts of the reflected beam. These shifts depend upon the shape of the incident beam, its polarization and on the material composition of the reflecting surface. In this article we suggest a novel approach that allows one to unambiguously isolate the beam-shape dependent aspects of GH and IF shifts. We show that this separation is possible as a result of some universal features of shifted distribution functions which are presented and discussed.

  20. Ion beam assisted film growth

    CERN Document Server

    Itoh, T

    2012-01-01

    This volume provides up to date information on the experimental, theoretical and technological aspects of film growth assisted by ion beams.Ion beam assisted film growth is one of the most effective techniques in aiding the growth of high-quality thin solid films in a controlled way. Moreover, ion beams play a dominant role in the reduction of the growth temperature of thin films of high melting point materials. In this way, ion beams make a considerable and complex contribution to film growth. The volume will be essential reading for scientists, engineers and students working in thi

  1. Molecular imaging with fast beams

    Energy Technology Data Exchange (ETDEWEB)

    Heber, O. [Weizmann Inst. of Science, Rehovoth (Israel). Dept. of Particle Physics; Zajfman, D. [Weizmann Inst. of Science, Rehovoth (Israel). Dept. of Particle Physics; Kella, D. [Weizmann Inst. of Science, Rehovoth (Israel). Dept. of Particle Physics; Vager, Z. [Weizmann Inst. of Science, Rehovoth (Israel). Dept. of Particle Physics; Watson, R.L. [Cyclotron Institute, Texas A and M University, College Station, Texas 77843 (United States); Horvat, V. [Cyclotron Institute, Texas A and M University, College Station, Texas 77843 (United States)

    1995-05-01

    Three dimensional imaging of the molecular dissociation process in fast collisions is presented with two different setups. One setup is for a fast molecular beam from an accelerator colliding with a gas target. The second setup is for a molecular target system and the collision process is with highly ionized fast beam. The advantages of each system are discussed. The three dimensional imaging of the molecular fragments is done with special detectors that combine the CCD image with time of flight data. An example of the molecular beam measurement is given for an 11 MeV B{sub 2} beam. (orig.).

  2. Profilaxia da peste

    Directory of Open Access Journals (Sweden)

    Renato dos Santos Araújo

    1967-12-01

    Full Text Available O autor parte da premissa de que a profilaxia da doença infecciosa decorre do encadeamento epidemiológico: fonte de infecção-veículo transmissor - receptivel, para explicar a da peste, baseada no mesmo princípio. Depois de citar os 4 principais complexos epidemiológicos da peste e afirmar que tôda a profilaxia da doença consiste em atingir os dois primeiros elos dessas cadeias e proteger o último, passa a classificar os vários métodos profiláticos empregados em 2 grandes grupos: o das medidas destrutivas ou provisórias e o das medidas supressivas ou definitivas. Entre as primeiras arrola a desratização e a despulização, às quais acrescenta o tratamento e isolamento do doente e do portaãor, e entre as segundas inclui a anti-ratização e a imunização. A seguir, passa a explicar em que consistem essas várias medidas profiláticas e quais os agentes de que se tem lançado mão para executá-las, expendendo ao curso dessa exposição o conceito que formula a respeito de cada uma delas, à guisa de apreciação do seu valor relativo. Enaltece sobretudo as medidas supressivas ou definitivas, às quais empresta a maior significação na luta antipestosa, chamando a atenção, em especial, para a necessidade de estudos imunológicos para aperfeiçoamento do poder imunitário das vacinas de germes vivos avirulentos, que considera um grande recurso para a profilaxia da doença, sobretudo para a proteção do rurícola, cujo labor e modo de vida o expõem inevitavelmente a se infectar, por ocasião da ocorrência de epizootias de origem silvestre. Concluída essa primeira parte, passa a fazer o histórico de como se desenvolveu a campanha contra a peste, no Brasil, desde a época da sua invasão em 1899 pelo pôrto de Santos até os nossos dias. Nesse histórico, detem-se um pouco para expôr a atuação do extinto Serviço Nacional de Peste, o qual, criado em 1941, após a reorganização do Departamento Nacional de Saúde, passou

  3. Transmission gratings for beam sampling and beam splitting.

    Science.gov (United States)

    Popov, E K; Loewen, E G; Neviére, M

    1996-06-01

    Transmission gratings have rarely been used for beam sampling because they require special properties from dielectric overcoatings, which, to the best of our knowledge, are described here for the first time. Although such gratings are often used as beam splitters, their nature can be modified along the same principles with thin metal coatings, which are described.

  4. Accelerators, Beams And Physical Review Special Topics - Accelerators And Beams

    Energy Technology Data Exchange (ETDEWEB)

    Siemann, R.H.; /SLAC

    2011-10-24

    Accelerator science and technology have evolved as accelerators became larger and important to a broad range of science. Physical Review Special Topics - Accelerators and Beams was established to serve the accelerator community as a timely, widely circulated, international journal covering the full breadth of accelerators and beams. The history of the journal and the innovations associated with it are reviewed.

  5. Beam rotation and shear in a large electron beam diode

    Energy Technology Data Exchange (ETDEWEB)

    Mansfield, C.R.; Oona, H.; Shurter, R.P.

    1990-01-01

    The time averaged electron beam current distribution of one of the electron guns of the Large Aperture Module (LAM) of the Aurora laser was measured as part of a larger set of experiments designed to study the electron beam transport to and energy deposition in the LAM laser chamber. The LAM laser chamber has a 1-m {times} 1-m aperture and is pumped from two sides along a 2-m length. A 10 ga. stainless steel sheet was placed inside the laser chamber and served multiple purposes. First, it was used to convert high energy electrons into X-rays in order to make radiograms of the electron beam. Second, the sheet was used as a Faraday cup to measure the total beam current. Third, individual Faraday cups were mounted on the plate to sample the time history of the electron beam at various positions. Each of the LAM electron gun diodes produces a beam of 750 kV electrons with a total current of about 500 kA which is relatively uniform over the cathode area of 1 m {times} 2 m. An applied magnetic field of about 1300 Gauss is used to prevent pinch of the beam during beam transport.

  6. LHC beam-beam compensation using wires and electron lenses

    CERN Document Server

    Dorda, U; Shiltsev, V; Zimmermann, F

    2007-01-01

    We present weak-strong simulation results for a possible application of current-carrying wires and electron lenses to compensate the LHC long-range and head-on beambeam interaction, respectively, for nominal and PACMAN bunches. We show that these measures have the potential to considerably increase the beam-beam limit, allowing for a corresponding increase in peak luminosity.

  7. O livro da alma

    Directory of Open Access Journals (Sweden)

    Oliver Tolle

    2016-12-01

    Full Text Available Trata-se de compreender os pressupostos da filosofia concreta pretendida por Johann Gottfried Herder (1744-1803 em uma série de textos redigidos durante as décadas de 1760-70. Se, por um lado, Herder demonstra afinidade com a mesma harmonia preestabelecida que está na base de leibnizianos como Gottsched e Baumgarten, por outro, ele aprofunda a discussão sobre a origem do conhecimento humano ao reduzir a importância de juízos de valor universal e acentuar a necessidade de uma aproximação constante das sensações que se agitam obscuramente no fundo da alma. Disso resulta uma concepção inusitada de sabedoria, a qual depende de uma renúncia à posse confortável de conhecimentos abstratos e da aceitação da natureza cambiante e apenas parcialmente perscrutável daquilo que nos move. Se com isso perde-se a certeza, abre-se em contrapartida uma dimensão essencialmente ativa e sensível de realização no mundo.

  8. O esvaziamento da cultura

    Directory of Open Access Journals (Sweden)

    Andressa Paula de Andrade

    2015-01-01

    Full Text Available Trata-se da resenha da obra "A civilização do espetáculo: uma radiografia do nosso tempo e da nossa cultura" de autoria de Mario Vargas Llosa, ganhador do Nobel de Literatura em 2010. O trabalho busca compreender este tempo em que a diversão assume maior relevância em detrimento da cultura profunda e reflexiva. Destarte, a todo momento se olha para o passado com vistas a examinar este fenômeno que se tornou um verdadeiro "esvaziamento cultural". Outrossim, busca-se elucidar que embora ocorra um progresso científico, acesso a educação e a tecnologia de forma vertiginosa, isso não significa que a as artes avançaram na mesma velocidade, pelo contrário, acabou estagnando e já não visa mais a modificação de estruturas, mas apenas entreter.

  9. O labirinto da contemporaneidade

    Directory of Open Access Journals (Sweden)

    Lang, Charles Elias

    2011-01-01

    Full Text Available O presente trabalho discute a modernidade e a produção da subjetividade contemporânea. Toma-se como modelo o labirinto de Eco (1985. Existem três tipos de labirintos: o labirinto clássico, o maneirístico, e a rede. O clássico é unicursal. Assim que se entra, a única coisa que se pode fazer é chegar ao centro e, do centro, só o que se pode fazer é encontrar uma saída. O maneirístico propõe escolhas alternativas. Todos os percursos levam a um ponto morto, com exceção de um que leva à saída. Na rede, cada ponto pode ter conexão com qualquer outro ponto. Se os labirintos anteriores têm um interior e um exterior, a rede, extensível ao infinito, não tem nem um dentro nem um fora. A partir deste modelo discute-se a produção de individualidades e subjetividades, do corpo como meio de comunicação e a produção de imagens do corpo através da mídia

  10. Dj Da Hai

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    Miko Da Hai is DJ at a Xi’an disco bar. At work, in his cool attire, the pulsing disco beat punctuated by his distinctive vocal commentary, he makes a striking impression. The job having come his way by chance, Miko is now a skilled and experienced DJ of eight years’ standing. This may be

  11. Asymmetric Bessel-Gauss beams.

    Science.gov (United States)

    Kotlyar, V V; Kovalev, A A; Skidanov, R V; Soifer, V A

    2014-09-01

    We propose a three-parameter family of asymmetric Bessel-Gauss (aBG) beams with integer and fractional orbital angular momentum (OAM). The aBG beams are described by the product of a Gaussian function by the nth-order Bessel function of the first kind of complex argument, having finite energy. The aBG beam's asymmetry degree depends on a real parameter c≥0: at c=0, the aBG beam is coincident with a conventional radially symmetric Bessel-Gauss (BG) beam; with increasing c, the aBG beam acquires a semicrescent shape, then becoming elongated along the y axis and shifting along the x axis for c≫1. In the initial plane, the intensity distribution of the aBG beams has a countable number of isolated optical nulls on the x axis, which result in optical vortices with unit topological charge and opposite signs on the different sides of the origin. As the aBG beam propagates, the vortex centers undergo a nonuniform rotation with the entire beam about the optical axis (c≫1), making a π/4 turn at the Rayleigh range and another π/4 turn after traveling the remaining distance. At different values of the c parameter, the optical nulls of the transverse intensity distribution change their position, thus changing the OAM that the beam carries. An isolated optical null on the optical axis generates an optical vortex with topological charge n. A vortex laser beam shaped as a rotating semicrescent has been generated using a spatial light modulator.

  12. Low intensity MTE beam in the SPS

    CERN Document Server

    Bohl, T

    2009-01-01

    In view of extracting fixed target type of beams for SPS fixed target physics or CNGS operation with the Multi-Turn-Extraction (MTE) scheme,an h = 16 MTE beam was produced in the CPS. The transmission and the longitudinal beam structure of this beam is compared with the beam extracted by CT.

  13. New concepts in deployable beam structures

    Science.gov (United States)

    Rhodes, M. D.

    1985-01-01

    The design of deployable structures involves a complicated tradeoff of packaging efficiency, the overall mechanism associated with deploying and latching beam joints, and the requirements and complexity of the beam deployer/repacker. Three longeron deployable beams, controllable geometry beams, and hybrid deployable/erectable beam concepts are evaluated.

  14. Laser beam shaping theory and techniques

    CERN Document Server

    Dickey, Fred M

    2000-01-01

    The mathematical and physical theory of lossless beam shaping; Gaussian beam shaping - diffraction theory and design; geometrical methods; optimization-based techniques for laser shaping optics; beam shaping with diffractive diffusers; multi-aperture beam integration systems; classical (non-laser) methods; current technology of beam profile measurements.

  15. Measurements of aperture and beam lifetime using movable beam scrapers in Indus-2 electron storage ring

    Science.gov (United States)

    Kumar, Pradeep; Ghodke, A. D.; Karnewar, A. K.; Holikatti, A. C.; Yadav, S.; Puntambekar, T. A.; Singh, G.; Singh, P.

    2013-12-01

    In this paper, the measurements of vertical and horizontal aperture which are available for stable beam motion in Indus-2 at beam energy 2.5 GeV using movable beam scrapers are presented. These beam scrapers are installed in one of the long straight sections in the ring. With the movement of beam scrapers towards the beam centre, the beam lifetime is measured. The beam lifetime data obtained from the movement of vertical and horizontal beam scrapers are analyzed. The contribution of beam loss due to beam-gas scattering (vacuum lifetime) and electron-electron scattering within a beam bunch (Touschek lifetime) is separated from the measured beam lifetime at different positions of the beam scrapers. Vertical and horizontal beam sizes at scrapers location are estimated from the scraper movement towards the beam centre in quantum lifetime limit and their values closely agree with measured value obtained using X-ray diagnostic beamline.

  16. Measurements of aperture and beam lifetime using movable beam scrapers in Indus-2 electron storage ring.

    Science.gov (United States)

    Kumar, Pradeep; Ghodke, A D; Karnewar, A K; Holikatti, A C; Yadav, S; Puntambekar, T A; Singh, G; Singh, P

    2013-12-01

    In this paper, the measurements of vertical and horizontal aperture which are available for stable beam motion in Indus-2 at beam energy 2.5 GeV using movable beam scrapers are presented. These beam scrapers are installed in one of the long straight sections in the ring. With the movement of beam scrapers towards the beam centre, the beam lifetime is measured. The beam lifetime data obtained from the movement of vertical and horizontal beam scrapers are analyzed. The contribution of beam loss due to beam-gas scattering (vacuum lifetime) and electron-electron scattering within a beam bunch (Touschek lifetime) is separated from the measured beam lifetime at different positions of the beam scrapers. Vertical and horizontal beam sizes at scrapers location are estimated from the scraper movement towards the beam centre in quantum lifetime limit and their values closely agree with measured value obtained using X-ray diagnostic beamline.

  17. Neutron beam measurement dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Amaro, C.R. [Idaho National Engineering Lab., Idaho Falls, ID (United States)

    1995-11-01

    This report describes animal dosimetry studies and phantom measurements. During 1994, 12 dogs were irradiated at BMRR as part of a 4 fraction dose tolerance study. The animals were first infused with BSH and irradiated daily for 4 consecutive days. BNL irradiated 2 beagles as part of their dose tolerance study using BPA fructose. In addition, a dog at WSU was irradiated at BMRR after an infusion of BPA fructose. During 1994, the INEL BNCT dosimetry team measured neutron flux and gamma dose profiles in two phantoms exposed to the epithermal neutron beam at the BMRR. These measurements were performed as a preparatory step to the commencement of human clinical trials in progress at the BMRR.

  18. Electron beam silicon purification

    Energy Technology Data Exchange (ETDEWEB)

    Kravtsov, Anatoly [SIA ' ' KEPP EU' ' , Riga (Latvia); Kravtsov, Alexey [' ' KEPP-service' ' Ltd., Moscow (Russian Federation)

    2014-11-15

    Purification of heavily doped electronic grade silicon by evaporation of N-type impurities with electron beam heating was investigated in process with a batch weight up to 50 kilos. Effective temperature of the melt, an indicative parameter suitable for purification process characterization was calculated and appeared to be stable for different load weight processes. Purified material was successfully approbated in standard CZ processes of three different companies. Each company used its standard process and obtained CZ monocrystals applicable for photovoltaic application. These facts enable process to be successfully scaled up to commercial volumes (150-300 kg) and yield solar grade silicon. (copyright 2014 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  19. Pulsed electron beam precharger

    Energy Technology Data Exchange (ETDEWEB)

    Finney, W.C. (ed.); Shelton, W.N.

    1990-01-01

    Florida State University is investigating the concept of pulsed electron beams for fly ash precipitation. This report describes the results and data on three of the subtasks of this project and preliminary work only on the remaining five subtasks. Described are the modification of precharger for pulsed and DC energization of anode; installation of the Q/A measurement system; and modification and installation of pulsed power supply to provide both pulsed and DC energization of the anode. The other tasks include: measurement of the removal efficiency for monodisperse simulated fly ash particles; measurement of particle charge; optimization of pulse energization schedule for maximum removal efficiency; practical assessment of results; and measurement of the removal efficiency for polydisperse test particles. 15 figs., 1 tab. (CK)

  20. Molecular-beam scattering

    Science.gov (United States)

    Vernon, M. F.

    1983-07-01

    The molecular-beam technique has been used in three different experimental arrangements to study a wide range of inter-atomic and molecular forces. Chapter 1 reports results of a low-energy (0.2 kcal/mole) elastic-scattering study of the He-Ar pair potential. The purpose of the study was to accurately characterize the shape of the potential in the well region, by scattering slow He atoms produced by expanding a mixture of He in N2 from a cooled nozzle. Chapter 2 contains measurements of the vibrational predissociation spectra and product translational energy for clusters of water, benzene, and ammonia. The experiments show that most of the product energy remains in the internal molecular motions. Chapter 3 presents measurements of the reaction Na + HC1 (FEMALE) NAC1 + H at collision energies of 5.38 and 19.4 kcal/mole. This is the first study to resolve both scattering angle and velocity for the reaction of a short lived (16 nsec) electronic excited state. Descriptions are given of computer programs written to analyze molecular-beam expansions to extract information characterizing their velocity distributions, and to calculate accurate laboratory elastic-scattering differential cross sections accounting for the finite apparatus resolution. Experimental results which attempted to determine the efficiency of optically pumping the Li(2(2)P/sub 3/2/) and Na(3(2)P/sub 3/2) excited states are given. A simple three-level model for predicting the steady-state fraction of atoms in the excited state is included.

  1. Molecular-beam scattering

    Energy Technology Data Exchange (ETDEWEB)

    Vernon, M.F.

    1983-07-01

    The molecular-beam technique has been used in three different experimental arrangements to study a wide range of inter-atomic and molecular forces. Chapter 1 reports results of a low-energy (0.2 kcal/mole) elastic-scattering study of the He-Ar pair potential. The purpose of the study was to accurately characterize the shape of the potential in the well region, by scattering slow He atoms produced by expanding a mixture of He in N/sub 2/ from a cooled nozzle. Chapter 2 contains measurements of the vibrational predissociation spectra and product translational energy for clusters of water, benzene, and ammonia. The experiments show that most of the product energy remains in the internal molecular motions. Chapter 3 presents measurements of the reaction Na + HCl ..-->.. NaCl + H at collision energies of 5.38 and 19.4 kcal/mole. This is the first study to resolve both scattering angle and velocity for the reaction of a short lived (16 nsec) electronic excited state. Descriptions are given of computer programs written to analyze molecular-beam expansions to extract information characterizing their velocity distributions, and to calculate accurate laboratory elastic-scattering differential cross sections accounting for the finite apparatus resolution. Experimental results which attempted to determine the efficiency of optically pumping the Li(2/sup 2/P/sub 3/2/) and Na(3/sup 2/P/sub 3/2/) excited states are given. A simple three-level model for predicting the steady-state fraction of atoms in the excited state is included.

  2. Determination of the chemical yield on the Fricke dosimetry for {sup 192}Ir sources used in brachytherapy; Determinacao do rendimento quimico na dosimetria Fricke para fontes de {sup 192}Ir usadas em braquiterapia

    Energy Technology Data Exchange (ETDEWEB)

    David, M.G.; Albuquerque, M.A.G.; Almeida, C.E. de, E-mail: marianogd08@gmail.com [Universidade do Estado do Rio de Janeiro (LCR/UERJ), Rio de Janeiro, RJ (Brazil). Lab. de Ciencias Radiologicas; Salata, C. [Comissao Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil); Rosado, P.H. [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    With the aim of developing a primary standard for the absorbed dose to water, for the {sup 192}Ir sources used in high dose rate brachytherapy, this work focuses on the determination of the chemical yield, G(Fe{sup +3}), using Fricke dosimetry, for the energy of those sources . The G(Fe{sup +3}) were determined the for three qualities of x-ray beams (150, 250 and 300 kV ) and for {sup 60}Co energy. The G(Fe{sup +3}) value for the average energy of {sup 192}Ir was obtained by linear fit, the found value was 1,555 ± 0,015 μmol/J. (author)

  3. CLIC Drive Beam Accelerating Structures

    CERN Document Server

    Wegner, Rolf

    2012-01-01

    Travelling structures for accelerating the high-current (4.2 A) CLIC Drive Beam to an energy of 2.37 GeV are presented. The structures are optimised for efficiency (full beam loading operation) and a desired filling time. Higher order modes are studied and are reduced by detuning along the structure and by damping with silicon carbide loads.

  4. NETWORK CODING BY BEAM FORMING

    DEFF Research Database (Denmark)

    2013-01-01

    Network coding by beam forming in networks, for example, in single frequency networks, can provide aid in increasing spectral efficiency. When network coding by beam forming and user cooperation are combined, spectral efficiency gains may be achieved. According to certain embodiments, a method...... cooperating with the plurality of user equipment to decode the received data....

  5. INTOR neutral beam injector concept

    Energy Technology Data Exchange (ETDEWEB)

    Metzler, D.H.; Stewart, L.D.

    1981-01-01

    The US INTOR phase 1 effort in the plasma heating area is described. Positive ion based sources extrapolated from present day technology are proposed. These sources operate at 175 keV beam energy for 6 s. Five injectors - plus one spare - inject 75 MW. Beam energy, source size, interface, radiation hardening, and many other studies are summarized.

  6. Beam splitting on weak illumination.

    Science.gov (United States)

    Snyder, A W; Buryak, A V; Mitchell, D J

    1998-01-01

    We demonstrate, in both two and three dimensions, how a self-guided beam in a non-Kerr medium is split into two beams on weak illumination. We also provide an elegant physical explanation that predicts the universal character of the observed phenomenon. Possible applications of our findings to guiding light with light are also discussed.

  7. Techniques to sort Bessel beams

    CSIR Research Space (South Africa)

    Dudley, Angela L

    2013-09-01

    Full Text Available -polar coordinate transformation, translating helically phased beams into a transverse phase gradient. By introducing two cylindrical lenses we can focus each of the azimuthal modes associated with each Bessel beam to a different lateral position in the Fourier...

  8. Hybrid beams in the LHC

    CERN Multimedia

    CERN Bulletin

    2011-01-01

    The first proton-ion beams were successfully circulated in the LHC a couple of weeks ago. Everything went so smoothly that the LHC teams had planned the first p-Pb collisions for Wednesday, 16 November. Unfortunately, a last-minute problem with a component of the PS required for proton acceleration prevented the LHC teams from making these new collisions. However, the way is open for a possible physics run with proton-lead collisions in 2012.   Members of the LHC team photographed when the first hybrid beams got to full energy. The proton and lead beams are visible on the leftmost screen up on the wall (click to enlarge the photo). The technical challenge of making different beams circulate in the LHC is by no means trivial. Even if the machine is the same, there are a number of differences when it is operated with beams of protons, beams of lead or beams of proton and lead. Provided that the beams are equal, irrespective of whether they consist of protons or lead nuclei, they revolve at the...

  9. Portal dosimetry in wedged beams

    NARCIS (Netherlands)

    Spreeuw, H.; Rozendaal, R.; Camargo, P.; Mans, A.; Wendling, M.; Olaciregui-Ruiz, I.; Sonke, J.J.; Herk, M. van; Mijnheer, B.

    2015-01-01

    Portal dosimetry using electronic portal imaging devices (EPIDs) is often applied to verify high-energy photon beam treatments. Due to the change in photon energy spectrum, the resulting dose values are, however, not very accurate in the case of wedged beams if the pixel-to-dose conversion for the s

  10. First LHC beam in 2017

    CERN Multimedia

    ATLAS Collaboration

    2017-01-01

    Impressions from the ATLAS control room while waiting for the very first 2017 LHC beams, from the traditional croissants in the morning to the "beam splashes" in the evening. The shift crew, online experts, run coordinators and management are looking forward the next steps of the LHC restart.

  11. BOUNDARY STABILIZATION OF TIMOSHENKO BEAM

    Institute of Scientific and Technical Information of China (English)

    YAN Qingxu

    2000-01-01

    In this paper, the stabilization problem of Timoshenko beam by some nonlinear boundary feedback controls is considered. By virtue of nonlinear semigroup theory and energy-perturbed method, it is shown that the vibration of the beam under the proposed control action decays exponentially or in negative power of time t as t → ∞.

  12. Report of the group on beam-beam effects in circular colliders

    Energy Technology Data Exchange (ETDEWEB)

    Furman, M.A.

    1991-05-01

    We present a summary of the discussions and conclusions of the working group on beam-beam effects for circular colliders. This group was part of the larger beam-beam dynamics group at the 7th ICFA Workshop on Beam Dynamics, on the subject Beam-Beam and Beam-Radiation Interactions,'' held at UCLA, May 13--16, 1991. 15 refs.

  13. Hollow chain-like beams

    CERN Document Server

    Cherepko, Dmitriy; Popkov, Ivan

    2012-01-01

    To generate hollow chain-like beams the diffraction of the first order Bessel beam by zone plate with two odd open Fresnel zone has been investigated. It has been shown that the capsules size is influenced by the number of the second odd open Fresnel zone and by the zone plate focal length. A hollow chain-like beam has been experimentally generated as a result of the first order Bessel beam diffraction by zone plate with the first and the ninth open Fresnel zones. The orbital angular momentum presence has been proved experimentally. The main features of the beam have been investigated. Sufficiently good agreement between experimental and numerically calculated results has been demonstrated.

  14. Cold and Slow Molecular Beam

    CERN Document Server

    Lu, Hsin-I; Wright, Matthew J; Patterson, Dave; Doyle, John M

    2011-01-01

    Employing a two-stage cryogenic buffer gas cell, we produce a cold, hydrodynamically extracted beam of calcium monohydride molecules with a near effusive velocity distribution. Beam dynamics, thermalization and slowing are studied using laser spectroscopy. The key to this hybrid, effusive-like beam source is a "slowing cell" placed immediately after a hydrodynamic, cryogenic source [Patterson et al., J. Chem. Phys., 2007, 126, 154307]. The resulting CaH beams are created in two regimes. One modestly boosted beam has a forward velocity of vf = 65 m/s, a narrow velocity spread, and a flux of 10^9 molecules per pulse. The other has the slowest forward velocity of vf = 40 m/s, a longitudinal temperature of 3.6 K, and a flux of 5x10^8 molecules per pulse.

  15. An introduction to beam physics

    CERN Document Server

    Berz, Martin; Wan, Weishi

    2015-01-01

    The field of beam physics touches many areas of physics, engineering, and the sciences. In general terms, beams describe ensembles of particles with initial conditions similar enough to be treated together as a group so that the motion is a weakly nonlinear perturbation of a chosen reference particle. Particle beams are used in a variety of areas, ranging from electron microscopes, particle spectrometers, medical radiation facilities, powerful light sources, and astrophysics to large synchrotrons and storage rings such as the LHC at CERN. An Introduction to Beam Physics is based on lectures given at Michigan State University’s Department of Physics and Astronomy, the online VUBeam program, the U.S. Particle Accelerator School, the CERN Academic Training Programme, and various other venues. It is accessible to beginning graduate and upper-division undergraduate students in physics, mathematics, and engineering. The book begins with a historical overview of methods for generating and accelerating beams, high...

  16. Transitoriedade ou o desterro da certeza

    Directory of Open Access Journals (Sweden)

    Paulo José Carvalho da Silva

    2012-12-01

    Full Text Available O tema da transitoriedade era lugar-comum da medicina da alma da primeira modernidade. Este artigo analisa algumas dessas fontes para mostrar como a dor do tempo e os males da alma atinentes eram relacionados a um modo de encarar a fugacidade do tempo e a fragilidade da vida. Dá-se destaque, sobretudo, às construções em torno da condição humana enquanto desterro da certeza.

  17. Irradiação de polímeros com feixe de elétrons: caracterização de íons positivos através da técnica de tempo-de-vôo Irradiation of polymers using electron beams: characterization of positive ions through the time-of-flight technique

    Directory of Open Access Journals (Sweden)

    Maria Luiza Miranda Rocco

    2004-02-01

    Full Text Available With the aim of studying the interaction of fast electrons with solid surfaces we have developed an experimental set-up based on electron stimulated desorption (ESD coupled to time-of-flight (TOF mass spectrometry. Poly(methyl methacrylate and poly(vynil chloride samples have been irradiated by a pulsed electron beam of 1.2 keV and 0.18 µs FWHM. The results show that H+ is the main ionic species to desorb after electron bombardment. In addition, other ionic fragments were also observed and assigned. These results show the potentiality of this technique in the study of ESD of polymers.

  18. A Refined Zigzag Beam Theory for Composite and Sandwich Beams

    Science.gov (United States)

    Tessler, Alexander; Sciuva, Marco Di; Gherlone, Marco

    2009-01-01

    A new refined theory for laminated composite and sandwich beams that contains the kinematics of the Timoshenko Beam Theory as a proper baseline subset is presented. This variationally consistent theory is derived from the virtual work principle and employs a novel piecewise linear zigzag function that provides a more realistic representation of the deformation states of transverse-shear flexible beams than other similar theories. This new zigzag function is unique in that it vanishes at the top and bottom bounding surfaces of a beam. The formulation does not enforce continuity of the transverse shear stress across the beam s cross-section, yet is robust. Two major shortcomings that are inherent in the previous zigzag theories, shear-force inconsistency and difficulties in simulating clamped boundary conditions, and that have greatly limited the utility of these previous theories are discussed in detail. An approach that has successfully resolved these shortcomings is presented herein. Exact solutions for simply supported and cantilevered beams subjected to static loads are derived and the improved modelling capability of the new zigzag beam theory is demonstrated. In particular, extensive results for thick beams with highly heterogeneous material lay-ups are discussed and compared with corresponding results obtained from elasticity solutions, two other zigzag theories, and high-fidelity finite element analyses. Comparisons with the baseline Timoshenko Beam Theory are also presented. The comparisons clearly show the improved accuracy of the new, refined zigzag theory presented herein over similar existing theories. This new theory can be readily extended to plate and shell structures, and should be useful for obtaining relatively low-cost, accurate estimates of structural response needed to design an important class of high-performance aerospace structures.

  19. Control And Transport Of Intense Electron Beams

    CERN Document Server

    Li, H

    2004-01-01

    The transport of intense beams for advanced accelerator applications with high-intensity beams such as heavy-ion inertial fusion, spallation neutron sources, and intense light sources requires tight control of beam characteristics over long distances. The University of Maryland Electron Ring (UMER), which uses low energy, high current electron beams to model the transport physics of intense space-charge-dominated beams, employs real-time beam characterization and control in order to optimize beam quality throughout the strong focusing lattice. We describe in this dissertation the main beam control techniques used in UMER, which include optimal beam steering by quadrupole scans, beam rotation correction using a skew corrector, rms envelope matching and optimization, empirical envelope matching, beam injection, and phase space reconstruction using a tomographic method. Using these control techniques, we achieved the design goals for UMER. The procedure is not only indispensable for optimum beam transport over l...

  20. Electrostatic wire stabilizing a charged particle beam

    Science.gov (United States)

    Prono, D.S.; Caporaso, G.J.; Briggs, R.J.

    1983-03-21

    In combination with a charged particle beam generator and accelerator, apparatus and method are provided for stabilizing a beam of electrically charged particles. A guiding means, disposed within the particle beam, has an electric charge induced upon it by the charged particle beam. Because the sign of the electric charge on the guiding means and the sign of the particle beam are opposite, the particles are attracted toward and cluster around the guiding means to thereby stabilize the particle beam as it travels.

  1. Coherent instabilities of a relativistic bunched beam

    Energy Technology Data Exchange (ETDEWEB)

    Chao, A.W.

    1982-06-01

    A charge-particle beam contained in an accelerator vacuum chamber interacts electromagnetically with its environment to create a wake field. This field than acts back on the beam, perturbing the particle motion. If the beam intensity is high enough, this beam-environment interaction may lead to an instability and to subsequent beam loss. The beam and its environment form a dynamical system, and it is this system that will be studied. 84 references.

  2. O Tema da Cidadania

    Directory of Open Access Journals (Sweden)

    Adriano Moreira

    2009-11-01

    Full Text Available Neste artigo tentaremos evidenciar a natureza pelo menos tripartida da cidadania que responde ao incontroladoglobalismo: uma que se confunde com os direitos humanos, exigentes querem seja o Estado o seu interlocutor,quer não exista tal interlocutor; outra que se insere na fenomenologia dos grandes espaços em formação, de que aUnião Europeia é exemplo, e a que o projecto da Constituição Europeia, agora em recolhimento de meditação, jáoferece o apoio de uma definição específica de direitos; e finalmente, a cidadania que diz respeito à relação com oEstado soberano em crise de redefinição, sobretudo, pelo que nos interessa, no espaço europeu.

  3. Fisiopatologia da asma grave

    OpenAIRE

    Todo-Bom, Ana; Mota-Pinto, Anabela

    2006-01-01

    Não tem resumo. Transcreve-se o primeiro parágrafo: A história natural da asma e os condicionalismos de uma evolução para formas moderadas ou graves não está completamente estabelecida. Contudo, quer os factores genéticos quer os factores ambientais, serão determinantes na fisiopatologia e no prognóstico da doença. A asma é, por definição, uma doença inflamatória crónica das vias aéreas caracterizada por uma obstrução brônquica generalizada mas variável que é, pelo menos parcialmente, reve...

  4. Avaliação da resposta bioquímica no câncer inicial de próstata: experiência uninstitucional comparando teleterapia exclusiva ou associada à braquiterapia de alta taxa de dose Evaluation of biochemical response on early prostate cancer: comparison between treatment with external beam radiation alone and in combination with high-dose rate conformal brachytherapy boost

    Directory of Open Access Journals (Sweden)

    Douglas Guedes de Castro

    2004-08-01

    Full Text Available OBJETIVO: Análise comparativa da resposta bioquímica em pacientes submetidos à teleterapia exclusiva ou associada à braquiterapia de alta taxa de dose para tumores localizados da próstata. MATERIAIS E MÉTODOS: De novembro de 1997 a janeiro de 2000, 74 pacientes foram submetidos à teleterapia com 45 Gy e reforço com braquiterapia de alta taxa de dose com irídio-192 e dose de 16 Gy em quatro inserções (BT. Estes foram comparados a 29 pacientes submetidos à teleterapia com 45 Gy e reforço com arcoterapia e dose mediana de 24 Gy (RT entre outubro de 1996 e fevereiro de 2000. Nos dois grupos houve associação ocasional de hormonioterapia neoadjuvante. Sobrevida atuarial livre de doença em três anos (SB3 e fatores prognósticos pré-tratamento da resposta bioquímica, como o antígeno prostático-específico inicial (PSAi, escore de Gleason da biópsia de próstata (EG e estádio clínico (EC, foram analisados. RESULTADOS: O seguimento mediano foi de 25 meses para o grupo RT e 37 meses para o BT. Na análise atuarial, a SB3 foi de 51% e 73% (p = 0,032 para RT e BT, respectivamente. Na análise estratificada pelo PSAi, a SB3 para RT e BT foi de 85,7% e 79,1% (p = 0,76 para PSAi 10 ng/mL, respectivamente. Quando estratificado pelo EG, a SB3 para RT e BT foi de 37% e 80% (p = 0,001 para EG 6 (p = 0,58; estratificando-se pelo EC, a SB3 para RT e BT foi de 36% e 74% (p = 0,018 para EC T2a (p = 0,692, respectivamente. O risco relativo bruto de recidiva bioquímica foi de 2,3 (95% IC: 1,0-5,1 para os pacientes tratados com RT, em relação à BT; quando ajustado pelo PSAi e EG, o risco relativo de recidiva bioquímica foi de 2,4 (95% IC: 1,0-5,7. CONCLUSÃO: A modalidade de tratamento foi fator prognóstico independente de recidiva bioquímica, com maior controle bioquímico associado à BT. Nossos resultados preliminares sugerem que o maior benefício com BT foi obtido nos pacientes com PSAi > 10 ng/mL, EC OBJECTIVE: To compare the

  5. [da Vinci surgical system].

    Science.gov (United States)

    Watanabe, Gou; Ishikawa, Norihiro

    2014-07-01

    The da Vinci surgical system was developed by Intuitive Surgical Inc. in the United States as an endoscopic surgical device to assist remote control surgeries. In 1998, the Da Vinci system was first used for cardiothoracic procedures. Currently a combination of robot-assisted internal thoracic artery harvest together with coronary artery bypass grafting (CABG) through a mini-incision (ThoraCAB) or totally endoscopic procedures including anastomoses under robotic assistance (TECAB) are being conducted for the treatment of coronary artery diseases. With the recent advances in catheter interventions, hybrid procedures combining catheter intervention with ThoraCAB or TECAB are anticipated in the future.On the other hand, with the decrease in number of coronary artery bypass surgeries, the share of valvular surgeries is expected to increase in the future. Among them, mitral valvuloplasty for mitral regurgitation is anticipated to be conducted mainly by low-invasive procedures, represented by minimally invasive cardiac surgery( MICS) and robot-assisted surgery. Apart from the intrinsic good surgical view, robotic-assisted systems offer additional advantages of the availability of an amplified view and the easy to observe the mitral valve in the physiological position. Thus, robotic surgical surgeries that make complicated procedures easier are expected to accomplish further developments in the future. Furthermore, while the number of surgeries for atrial septal defects has decreased dramatically following the widespread use of Amplatzer septal occluder, robotic surgery may become a good indication for cases in which the Amplatzer device is not indicated. In Japan, clinical trial of the da Vinci robotic system for heart surgeries has been completed. Statutory approval of the da Vinci system for mitral regurgitation and atrial septal defects is anticipated in the next few years.

  6. Intra-cavity vortex beam generation

    CSIR Research Space (South Africa)

    Naidoo, Darryl

    2011-08-01

    Full Text Available ? per photon, and may be found as beams expressed in several basis functions, including Laguerre-Gaussian (LGpl) beams1, Bessel-Gaussian beams3 and Airy beams4 to name but a few. LG0l are otherwise known as vortex beams and LG0l beams are routinely... are represented by ?petals? and we show that through a full modal decomposition, the ?petal? fields are a superposition of two LG0l modes. Keywords: Vortex beams, SLM, Laguerre-Gaussian beams, Porro-prism resonator, Petals. 1. INTRODUCTION It is well...

  7. Relativistic electron beams above thunderclouds

    Directory of Open Access Journals (Sweden)

    M. Füllekrug

    2011-08-01

    Full Text Available Non-luminous relativistic electron beams above thunderclouds have been detected by the radio signals of low frequency ∼40–400 kHz which they radiate. The electron beams occur ∼2–9 ms after positive cloud-to-ground lightning discharges at heights between ∼22–72 km above thunderclouds. Intense positive lightning discharges can also cause sprites which occur either above or prior to the electron beam. One electron beam was detected without any luminous sprite which suggests that electron beams may also occur independently of sprites. Numerical simulations show that beams of electrons partially discharge the lightning electric field above thunderclouds and thereby gain a mean energy of ∼7 MeV to transport a total charge of ∼−10 mC upwards. The impulsive current ∼3 × 10−3 Am−2 associated with relativistic electron beams above thunderclouds is directed downwards and needs to be considered as a novel element of the global atmospheric electric circuit.

  8. ATLAS diamond Beam Condition Monitor

    CERN Document Server

    Gorišek, A; Dolenc, I; Frais-Kölbl, H; Griesmayer, E; Kagan, H; Korpar, S; Kramberger, G; Mandic, I; Meyer, M; Mikuz, M; Pernegger, H; Smith, S; Trischuk, W; Weilhammer, P; Zavrtanik, M

    2007-01-01

    The ATLAS experiment has chosen to use diamond for its Beam Condition Monitor (BCM) given its radiation hardness, low capacitance and short charge collection time. In addition, due to low leakage current diamonds do not require cooling. The ATLAS Beam Condition Monitoring system is based on single beam bunch crossing measurements rather than integrating the accumulated particle flux. Its fast electronics will allow separation of LHC collisions from background events such as beam gas interactions or beam accidents. There will be two stations placed symmetrically about the interaction point along the beam axis at . Timing of signals from the two stations will provide almost ideal separation of beam–beam interactions and background events. The ATLAS BCM module consists of diamond pad detectors of area and thickness coupled to a two-stage RF current amplifier. The production of the final detector modules is almost done. A S/N ratio of 10:1 has been achieved with minimum ionizing particles (MIPs) in the test bea...

  9. Generation of electron Airy beams.

    Science.gov (United States)

    Voloch-Bloch, Noa; Lereah, Yossi; Lilach, Yigal; Gover, Avraham; Arie, Ady

    2013-02-21

    Within the framework of quantum mechanics, a unique particle wave packet exists in the form of the Airy function. Its counterintuitive properties are revealed as it propagates in time or space: the quantum probability wave packet preserves its shape despite dispersion or diffraction and propagates along a parabolic caustic trajectory, even though no force is applied. This does not contradict Newton's laws of motion, because the wave packet centroid propagates along a straight line. Nearly 30 years later, this wave packet, known as an accelerating Airy beam, was realized in the optical domain; later it was generalized to an orthogonal and complete family of beams that propagate along parabolic trajectories, as well as to beams that propagate along arbitrary convex trajectories. Here we report the experimental generation and observation of the Airy beams of free electrons. These electron Airy beams were generated by diffraction of electrons through a nanoscale hologram, which imprinted on the electrons' wavefunction a cubic phase modulation in the transverse plane. The highest-intensity lobes of the generated beams indeed followed parabolic trajectories. We directly observed a non-spreading electron wavefunction that self-heals, restoring its original shape after passing an obstacle. This holographic generation of electron Airy beams opens up new avenues for steering electronic wave packets like their photonic counterparts, because the wave packets can be imprinted with arbitrary shapes or trajectories.

  10. Asymmetric Laguerre-Gaussian beams

    Science.gov (United States)

    Kovalev, A. A.; Kotlyar, V. V.; Porfirev, A. P.

    2016-06-01

    We introduce a family of asymmetric Laguerre-Gaussian (aLG) laser beams. The beams have been derived via a complex-valued shift of conventional LG beams in the Cartesian plane. While propagating in a uniform medium, the first bright ring of the aLG beam becomes less asymmetric and the energy is redistributed toward peripheral diffraction rings. The projection of the orbital angular momentum (OAM) onto the optical axis is calculated. The OAM is shown to grow quadratically with increasing asymmetry parameter of the aLG beam, which equals the ratio of the shift to the waist radius. Conditions for the OAM becoming equal to the topological charge have been derived. For aLG beams with zero radial index, we have deduced an expression to define the intensity maximum coordinates and shown the crescent-shaped intensity pattern to rotate during propagation. Results of the experimental generation and rotation of aLG beams agree well with theoretical predictions.

  11. Optical tractor Bessel polarized beams

    Science.gov (United States)

    Mitri, F. G.; Li, R. X.; Guo, L. X.; Ding, C. Y.

    2017-01-01

    Axial and transverse radiation force cross-sections of optical tractor Bessel polarized beams are theoretically investigated for a dielectric sphere with particular emphasis on the beam topological charge (or order), half-cone angle and polarization. The angular spectrum decomposition method (ASDM) is used to derive the non-paraxial electromagnetic (EM) field components of the Bessel beams. The multipole expansion method using vector spherical harmonics is utilized and appropriate beam-shape coefficients are derived in order to compute the radiation force cross-sections. The analysis has no limitation to a particular range of frequencies such that the Rayleigh, Mie or geometrical optics regimes can all be considered effectively using the present rigorous formalism. The focus of this investigation is to identify some of the tractor beam conditions so as to achieve retrograde motion of a dielectric sphere located arbitrarily in space. Numerical computations for the axial and transverse radiation force cross-sections are presented for linear, right-circular, radial, azimuthal and mixed polarizations of the individual plane waves forming the Bessel beams of zeroth- and first-order (with positive or negative helicity), respectively. As the sphere shifts off the beam's axis, the axial pulling (tractor) force is weakened. Moreover, the transverse radiation force cross-section field changes with the sphere's size factor ka (where k is the wavenumber and a is the sphere radius). Both stable and unstable equilibrium regions around the beam's axis are found, depending on the choice of ka and the half-cone angle α0. These results are particularly important in the development of emergent technologies for the photophoretic assembly of optically-engineered (meta)materials with designed properties using optical tractor (vortex) beams, particle manipulation, levitation and positioning, and other applications.

  12. Beam Instrumentation for the Single Electron DAFNE Beam Test Facility

    CERN Document Server

    Mazzitelli, G; Valente, P; Vescovi, M

    2003-01-01

    The DAΦNE Beam Test Facility (BTF) has been successfully commissioned in February 2002, and started operation in November of the same year. Although the BTF is a beam transfer line optimized for single particle production, mainly for high energy detectors calibration, it can provide electrons and positrons in a wide range of multiplicity: between 1-1010, with energies from a few tens of MeV up to 800 MeV. The large multiplicity range requires many different diagnostic devices, from high-energy calorimeters and ionization/fluorescence chambers in the few particles range, to standard beam diagnostics systems. The schemes of operation, the commissioning results, as well as the beam diagnostics are presented.

  13. Simulating Transient Effects of Pulsed Beams on Beam Intercepting Devices

    CERN Document Server

    Richter, Herta; Noah Messomo, Etam

    2011-01-01

    The development in the physics community towards higher beam power through the possibilities of particle accelerators lead to challenges for the developers of elements which are exposed to effect of particle beams (beam intercepting devices = BIDs). For the design of BIDs, the increasing heat load onto these devices due to energetic and focused beams and - in most cases - their highly pulsed nature has to be taken into account. The physics requirements are sometimes opposed to the current state of the art. As one possibility of many in combining the different aspects for these ambitious demands, two highly developed computer programs, namely FLUKA and ANSYS AUTODYN, were joined for this dissertation. The former is a widely enhanced Monte-Carlo-code which specializes on the interaction of particles with static matter, while the latter is a versatile explicit code for the simulation of highly dynamic processes. Both computer programs were developed intensively over years and are still continuously enhanced in o...

  14. Electron beam machining using rotating and shaped beam power distribution

    Science.gov (United States)

    Elmer, John W.; O'Brien, Dennis W.

    1996-01-01

    An apparatus and method for electron beam (EB) machining (drilling, cutting and welding) that uses conventional EB guns, power supplies, and welding machine technology without the need for fast bias pulsing technology. The invention involves a magnetic lensing (EB optics) system and electronic controls to: 1) concurrently bend, focus, shape, scan, and rotate the beam to protect the EB gun and to create a desired effective power-density distribution, and 2) rotate or scan this shaped beam in a controlled way. The shaped beam power-density distribution can be measured using a tomographic imaging system. For example, the EB apparatus of this invention has the ability to drill holes in metal having a diameter up to 1000 .mu.m (1 mm or larger), compared to the 250 .mu.m diameter of laser drilling.

  15. Beam Transfer and Machine Protection

    CERN Document Server

    Kain, V

    2016-01-01

    Beam transfer, such as injection into or extraction from an accelerator, is one of the most critical moments in terms of machine protection in a high-intensity machine. Special equipment is used and machine protection aspects have to be taken into account in the design of the beam transfer concepts. A brief introduction of the principles of beam transfer and the equipment involved will be given in this lecture. The main concepts of machine protection for injection and extraction will be presented, with examples from the CERN SPS and LHC.

  16. Photoelectron photoion molecular beam spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Trevor, D.J.

    1980-12-01

    The use of supersonic molecular beams in photoionization mass spectroscopy and photoelectron spectroscopy to assist in the understanding of photoexcitation in the vacuum ultraviolet is described. Rotational relaxation and condensation due to supersonic expansion were shown to offer new possibilities for molecular photoionization studies. Molecular beam photoionization mass spectroscopy has been extended above 21 eV photon energy by the use of Stanford Synchrotron Radiation Laboratory (SSRL) facilities. Design considerations are discussed that have advanced the state-of-the-art in high resolution vuv photoelectron spectroscopy. To extend gas-phase studies to 160 eV photon energy, a windowless vuv-xuv beam line design is proposed.

  17. Beam stability at CTF3

    CERN Document Server

    Persson, T

    2012-01-01

    The two-beam acceleration tested at CTF3 imposes very tight tolerances on the drive beam stability. A description of the specialized monitoring tool developed to identify the drifts and jitter in the machine is presented. It compares all the relevant signals in an on-line manner to help the operator to identify drifts and to log data for off-line analysis. The main sources for the drifts of the drive beam have been identified and their causes are described. A feedback applied to the RF was implemented to reduce the effects. It works by changing the waveform for the pulse compression to compensate for the drifts.

  18. Beam-Beam Simulations with GUINEA-PIG

    CERN Document Server

    Schulte, Daniel

    1998-01-01

    While the bunches in a linear collider cross only once, due to their small size they experience a strong beam-beam effect. GUINEA-PIG is a code to simulate the impact of this effect on luminosity and back ground. A short overview of the program is given with examples of its application to the back ground strudies for TESLA, the top quark threshold scan and a possible luminosity monitor, as well as some results for CLIC.

  19. The two means method for the attenuation coefficient determination of archaeological ceramics from the North of Parana; Metodo dos dois meios para a determinacao do coeficiente de atenuacao de ceramicas arqueologicas do norte do Parana

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Richard Maximiliano Cunha e

    1997-12-31

    This work reports an alternative methodology for the linear attenuation coefficient determination ({mu} {rho}) of irregular form samples, in such a way that is not necessary to consider the sample thickness. With this methodology, indigenous archaeological ceramics fragments from the region of Londrina, north of Parana, were studied. These ceramics fragments belong to the Kaingaing and Tupiguarani traditions. The equation for the {mu} {rho} determination employing the two mean method was obtained and it was used for {mu} {rho} determination by the gamma ray beam attenuation if immersed ceramics, by turns, in two different means with known linear attenuation coefficient. By the other side, {mu} theoretical value was determined with the XCOM computer code. This code uses as input the ceramics chemistry composition and provides an energy versus mass attenuation coefficient table. In order to validate the two mean method validation, five ceramics samples of thickness 1.15 cm and 1.87 cm were prepared with homogeneous clay. Using these ceramics, {mu} {rho} was determined using the attenuation method, and the two mean method. The result obtained for {mu} {rho} and its respective deviation were compared for these samples, for the two methods. With the obtained results, it was concluded that the two means method is good for the linear attenuation coefficient determination of materials of irregular shape, what is suitable, specially, for archaeometric studies. (author) 25 refs., 29 figs., 28 tabs.

  20. Two media method for linear attenuation coefficient determination of irregular soil samples; Metodo dos dois meios para a determinacao do coeficiente de atenuacao linear de amostras irregulares de solos

    Energy Technology Data Exchange (ETDEWEB)

    Vici, Carlos Henrique Georges

    2004-07-01

    In several situations of nuclear applications, the knowledge of gamma-ray linear attenuation coefficient for irregular samples is necessary, such as in soil physics and geology. This work presents the validation of a methodology for the determination of the linear attenuation coefficient ({mu}) of irregular shape samples, in such a way that it is not necessary to know the thickness of the considered sample. With this methodology irregular soil samples (undeformed field samples) from Londrina region, north of Parana were studied. It was employed the two media method for the {mu} determination. It consists of the {mu} determination through the measurement of a gamma-ray beam attenuation by the sample sequentially immersed in two different media, with known and appropriately chosen attenuation coefficients. For comparison, the theoretical value of {mu} was calculated by the product of the mass attenuation coefficient, obtained by the WinXcom code, and the measured value of the density sample. This software employs the chemical composition of the samples and supplies a table of the mass attenuation coefficients versus the photon energy. To verify the validity of the two media method, compared with the simple gamma ray transmission method, regular pome stone samples were used. With these results for the attenuation coefficients and their respective deviations, it was possible to compare the two methods. In this way we concluded that the two media method is a good tool for the determination of the linear attenuation coefficient of irregular materials, particularly in the study of soils samples. (author)

  1. Test Beam Coordination: 2003 ATLAS Combined Test Beam

    CERN Multimedia

    Di Girolamo, B.

    The 2003 Test Beam Period The 2003 Test Beam period has been very fruitful for ATLAS. In spite of several days lost because of the accelerator problems, ATLAS has been able to achieve many results: FCAL has completed the calibration program in H6 Tilecal has completed the calibration program in H8 Pixel has performed extensive studies with normal and high intensity beams (up to 1.4*108 hadrons/spill) SCT has completed a variety of studies with quite a high number of modules operated concurrently TRT has performed several studies at high, low and very low energy (first use of the new H8 beam in the range 1 to 9 GeV) Muons (MDT,RPC and TGC) have been operating a large setup for about 5 months. The almost final MDT ROD (MROD) has been integrated in the readout and the final trigger electronics for TGC and RPC has been tested and certified with normal beam and during dedicated 40 MHz beam periods. The TDAQ has exploited a new generation prototype successfully and the new Event Filter infrastructure f...

  2. Observations and open questions in beam-beam interactions

    Energy Technology Data Exchange (ETDEWEB)

    Sen, Tanaji; /Fermilab

    2010-08-01

    The first of the hadron colliders, ISR, started operation in 1970. In the following years, the hadron colliders to follow were the SPS (started 1980), the Tevatron (started 1987 first as a fixed target machine), RHIC (started 2000) and most recently the LHC, which started in 2008. HERA was a hybrid that collided electrons and protons. All of these accelerators had or have their performance limited by the effects of the beam-beam interactions. That has also been true for the electron-positron colliders such as LEP, CESR, KEKB and PEPII. In this article I will discuss how the beam-beam limitations arose in some of these machines. The discussion will be focused on common themes that span the different colliders. I will mostly discuss the hadron colliders but sometimes discuss the lepton colliders where relevant. Only a handful of common accelerator physics topics are chosen here, the list is not meant to be exhaustive. A comparative review of beam-beam performance in the ISR, SPS and Tevatron (ca 1989) can be found in reference. Table 1 shows the relevant parameters of colliders (excluding the LHC), which have accelerated protons.

  3. Experimental observations and theoretical models for beam-beam phenomena

    Energy Technology Data Exchange (ETDEWEB)

    Kheifets, S.

    1981-03-01

    The beam-beam interaction in storage rings exhibits all the characteristics of nonintegrable dynamical systems. Here one finds all kinds of resonances, closed orbits, stable and unstable fixed points, stochastic layers, chaotic behavior, diffusion, etc. The storage ring itself being an expensive device nevertheless while constructed and put into operation presents a good opportunity of experimentally studying the long-time behavior of both conservative (proton machines) and nonconservative (electron machines) dynamical systems - the number of bunch-bunch interactions routinely reaches values of 10/sup 10/-10/sup 11/ and could be increased by decreasing the beam current. At the same time the beam-beam interaction puts practical limits for the yield of the storage ring. This phenomenon not only determines the design value of main storage ring parameters (luminosity, space charge parameters, beam current), but also in fact prevents many of the existing storage rings from achieving design parameters. Hence, the problem has great practical importance along with its enormous theoretical interest. A brief overview of the problem is presented.

  4. Libera Electron Beam Position Processor

    CERN Document Server

    Ursic, Rok

    2005-01-01

    Libera is a product family delivering unprecedented possibilities for either building powerful single station solutions or architecting complex feedback systems in the field of accelerator instrumentation and controls. This paper presents functionality and field performance of its first member, the electron beam position processor. It offers superior performance with multiple measurement channels delivering simultaneously position measurements in digital format with MHz kHz and Hz bandwidths. This all-in-one product, facilitating pulsed and CW measurements, is much more than simply a high performance beam position measuring device delivering micrometer level reproducibility with sub-micrometer resolution. Rich connectivity options and innate processing power make it a powerful feedback building block. By interconnecting multiple Libera electron beam position processors one can build a low-latency high throughput orbit feedback system without adding additional hardware. Libera electron beam position processor ...

  5. Squid based beam current meter

    Energy Technology Data Exchange (ETDEWEB)

    Kuchnir, M.

    1983-11-25

    A SQUID based beam current meter has the capability of measuring the current of a beam with as little as 30 x 155 antiprotons (with a signal to noise ratio of 2). If low noise dc current is used to cancel most of the beam or an up-down counter is used to count auto-resets this sensitivity will be available at any time in the acumulation process. This current meter will therefore be a unique diagnostic tool for optimizing the performance of several Tev I components. Besides requiring liquid helium it seems that its only drawback is not to follow with the above sensitivity a sudden beam change larger than 16 ..mu..A, something that could be done using a second one in a less sensitive configuration.

  6. STOCHASTIC COOLING FOR BUNCHED BEAMS.

    Energy Technology Data Exchange (ETDEWEB)

    BLASKIEWICZ, M.

    2005-05-16

    Problems associated with bunched beam stochastic cooling are reviewed. A longitudinal stochastic cooling system for RHIC is under construction and has been partially commissioned. The state of the system and future plans are discussed.

  7. Beam instability Workshop - plenary sessions

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    The purpose of this workshop was to provide a review of the mechanisms of limiting beam instabilities, their cures, including feedback, and beam measurement for synchrotron radiation light sources. 12 plenary sessions took place whose titles are: 1) challenging brilliance and lifetime issues with increasing currents; 2) limiting instabilities in multibunch; 3) experience from high currents in B factories; 4) longitudinal dynamics in high intensity/bunch; 5) Transverse instabilities for high intensity/bunch; 6) working group introduction from ESRF experience; 7) impedance modelling: simulations, minimization; 8) report on the broadband impedance measurements and modelling workshop; 9) feedback systems for synchrotron light sources; 10) beam instabilities diagnostics; 11) harmonic cavities: the pros and cons; and 12) experimental study of fast beam-ion instabilities at PLS. This document gathers the 12 articles that were presented during these sessions.

  8. Monitor of SC beam profiles

    CERN Multimedia

    1977-01-01

    A high-resolution secondary emission grid for the measurement of SC beam profiles. Modern techniques of metal-ceramic bonding, developed for micro-electronics, have been used in its construction. (See Annual Report 1977 p. 105 Fig. 12.)

  9. Electrostatic beam-position monitor

    CERN Multimedia

    CERN PhotoLab

    1969-01-01

    Electrostatic beam-position monitor installed in its final location (bake-out cover removed). The ISR will contain about 110 of these monitors. Their accuracy is better than 1 mm, their band width about 1 MHz.

  10. RIKEN RI Beam Factory project

    Energy Technology Data Exchange (ETDEWEB)

    Yano, Yasushige; Goto, Akira; Katayama, Takeshi [Institute of Physical and Chemical Research, Wako, Saitama (Japan)

    1997-03-01

    The RARF proposes `RIKEN RI Beam Factory` as a next facility-expanding project. The factory makes it the primary aim to provide RI (Radioactive Isotope) beams covering over the whole atomic-mass range with the world-highest intensity in a wide energy range up to several hundreds MeV/nucleon. These RI beams are generated by the fragmentation of high-intensity heavy-ion beams. For the efficient production heavy-ion energies will be boosted up to over 100 MeV/nucleon even for very heavy ions by a K2500-MeV superconducting ring cyclotron serving as a post accelerator of the existing K540-MeV ring cyclotron. A new type of experimental installation called `MUSES` (Multi-USe Experimental Storage rings) will be constructed as well. With MUSES, various types of unique colliding experiments will become possible. (author)

  11. LHC beam loss pattern recognition

    CERN Document Server

    Marsili, A; Puzo, P

    2011-01-01

    One of the systems protecting CERN’s Large Hadron Collider (LHC) is the Beam Loss Monitoring system (BLM). More than 3600 monitors are installed around the ring. The beam losses are permanently integrated over 12 different time intervals (from 40 microseconds to 84 seconds). When any loss exceeds the thresholds defined for the integration window, the beam is removed from the machine. Understanding the origin of a beam loss is crucial for machine operation, as it can help to avoid a repetition of the same scenario. The signals read from given monitors can be considered as entries of a vector. This article presents how a loss map of unknown cause can be decomposed using vector based analysis derived from well-known loss scenarios. The algorithms achieving this decomposition are described, as well as the accuracy of the results.

  12. Center for Beam Physics, 1992

    Energy Technology Data Exchange (ETDEWEB)

    1993-06-01

    This report contains the following information on the center for beam physics: Facilities; Organizational Chart; Roster; Profiles of Staff; Affiliates; Center Publications (1991--1993); and 1992 Summary of Activities.

  13. High Precision Electon Beam Polarimetry

    National Research Council Canada - National Science Library

    Dutta, D

    2016-01-01

    Over the last three decades high precision electron beam polarimetry has been at the fore-front of progress made in leveraging the spin degrees of freedom in nuclear and particle physics experiments...

  14. O paradoxo da legitimidade a partir da legalidade segundo Habermas

    Directory of Open Access Journals (Sweden)

    Aylton Barbieri Durão

    2010-12-01

    Full Text Available http://dx.doi.org/10.5007/1677-2954.2008v7n2p233A autonomia jurídica surge da conexão co-originária entre a autnomia privada dos indivíduos e a autonomia pública dos cidadãos, a qual, contudo, ficou velada ao longo da história da filosofia política e jurídica por causa da herança metafísica do direito natural racional e da filosofia da consciência que gerou uma relação de competição entre os direitos humanos e a vontade soberana do povo. Por causa desta conexão entre a autonomia privada e pública, o processo democrática de produção de normas jurídicas apresenta um aparente paradoxo porque os cidadãos tanto podem aprovar as normas motivados pela busca do êxito da racionalidade estratégica como orientados pelo reconhecimento de sua validade através da racionalidade comunicativa, o qual se dissolve, contudo, quando se considera a democracia como um processo aberto para a solidariedade dos cidadãos no mundo da vida.

  15. O Cognitivismo e o problema da Cientificidade da Psicologia

    OpenAIRE

    Arja Castañon, Gustavo

    2010-01-01

    Este artigo trata do problema do estatuto científico da psicologia. Seu objetivo é avaliar em que medida o cognitivismo solucionou objeções históricas levantadas contra a possibilidade de uma psicologia científica. Com base em avaliação de textos clássicos da “revolução cognitiva”, se conclui que esta abordagem apresentou um projeto filosófico de ciência psicológica que resolveu a maior parte dos problemas ontológicos e epistemológicos endêmicos da disciplina, como o da natureza inquantificáv...

  16. Parameter estimation in truss beams using Timoshenko beam model with damping

    Science.gov (United States)

    Sun, C. T.; Juang, J. N.

    1983-01-01

    Truss beams with members having viscous damping are modeled with a Timoshenko beam. Procedures for deriving the equivalent bending rigidity, transverse shear rigidity, and damping are presented. Explicit expressions for these equivalent beam properties are obtained for a specific truss beam. The beam model thus established is then used to investigate the effect of damping in free vibration. Finally, the beam is employed in the estimation of structural parameters in a simply-supported truss beam using a random search algorithm.

  17. Studies of beam dynamics in relativistic klystron two- beam accelerators

    Science.gov (United States)

    Lidia, Steven Michael

    Two-beam accelerators (TBAs) based upon free-electron lasers (FELs) or relativistic klystrons (RK-TBAs) have been proposed as efficient power sources for next generation high-energy linear colliders. Studies have demonstrated the possibility of building TBAs from X-band (~8-12 GHz) through Ka-band (~30-35 GHz) frequency regions. A new method of simulating the beam dynamics in accelerators of this type has been developed in this dissertation. There are three main components to this simulation. The first is a tracking algorithm to generate nonlinear transfer maps for pushing noninteracting particles through the external fields. A mapping algorithm is used so that tens or hundreds of thousands of macroparticles can be pushed from the solution of a few hundreds of differential equations. This is a great cost-savings device from the standpoint of CPU cycles. It can increase by several orders of magnitude the number of macroparticles that take place in the simulation, enabling more accurate modeling of the evolution of the beam distribution and enhanced sensitivity to effects due to the beam's halo. The second component is a 3D Particle-In-Cell (PIC) algorithm that solves a set of Helmholtz equations for the self-fields, including the conducting boundary condition, and generates impulses that are interleaved with the nonlinear maps by means of a split- operator algorithm. The Helmholtz equations are solved by a multi-grid algorithm. The third component is an equivalent circuit equation solver that advances the modal rf cavity fields in time due to excitation by the modulated beam. The beam-cavity interaction is analyzed and divided naturally into two distinct times scales. The RTA project is described, and the simulation code is used to design the latter portions of the experiment. Detailed calculations of the beam dynamics and of the rf cavity output are presented and discussed. A beamline design is presented that will generate nearly 1.2 TW of power from 40 input, gain

  18. Ultraviolet Photodissociation of Molecular Beams.

    Science.gov (United States)

    1980-12-15

    Continue on reerse side if neceesry and identify by block number) Photodissociation , excimer laser, nitrocompounds, carbon disulfide, sulfur dioxide ...4 ULTRAVIOLET PHOTODISSOCIATION OF MOLECULAR BEAMS. * TYPE OF REPORT (TECHNICAL, FINAL, ETC.) FINAL REPOT OR PERIOD 0/01/77 - 9/30/80 AUTHOR (S... Photodissociation of Final report for period 10/01/77 - 9/30/80 Molecular Beams 6. PERFORMIN, CRG. REPORT NUMBER 7. AUTHOR(e) S. CONTRACT OR GRANT NUMBER(e) R

  19. Electrostatic ion beam scanning system

    Energy Technology Data Exchange (ETDEWEB)

    Harper, G.C.; Curtis, W.D.

    1978-04-01

    An electrostatic scanning system has been designed and built to uniformly implant a 1 cm/sup 2/ sample with a charged particle beam. The full angular scan capability for a 2 MeV beam is 0.5 degrees at 6 kV p-p. The design of the system is extremely simple so it is very compact, easy to operate, and has shown very good reliability.

  20. Nonlinear optimization of beam lines

    CERN Document Server

    Tomás Garcia, Rogelio

    2006-01-01

    The current final focus systems of linear colliders have been designed based on the local compensation scheme proposed by P. Raimondi and A. Seryi [1]. However, there exist remaining aberrations that deteriorate the performance of the system. This paper develops a general algorithm for the optimization of beam lines based on the computation of the high orders of the transfer map using MAD-X [2] and PTC [3]. The algorithm is applied to the CLIC [4] Beam Delivery System (BDS).

  1. Determination of attenuation factors for mortar of barite in terms of environmental dose equivalent and effective dose; Determinacao de fatores de atenuacao para argamassa de barita em termos do equivalente de dose ambiental e dose efetiva

    Energy Technology Data Exchange (ETDEWEB)

    Almeida Junior, Airton T.; Campos, L.L.R., E-mail: airtontavares@uol.com.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Araujo, F.G.S. [Universidade Federal de Ouro Preto (UFOP), Ouro Preto, MG (Brazil); Santos, M.A.P. [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil); Nogueira, M.S., E-mail: mnogueira@cdtn.br [Centro de Desenvolvimeto da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2014-07-01

    This work addresses the characterization of barite mortars used as Xray shielding materials through the following quantities: mass attenuation coefficient, air kerma, effective dose and ambient dose - H⁎(10). The experiment was carried out with the use of the following reference qualities: RQR4, RQR6, RQR9 e RQR10, specified in accordance with norm IEC 61267: Medical diagnostic Xray equipment - radiation conditions for use in the determination of characteristics. In this study values was determined experimentally for the attenuation of the Cream barite (density 2.99g/cm{sup 3}, collected in the state of Sao Paulo), Purple barite (density 2.95g/cm{sup 3}, collected in the state of Bahia) and White barite (density 3.10g/cm{sup 3}, collected in the state of Paraiba). These materials, in the form of mortar, were disposed in the form of squares namely poof bodies, whose dimensions were 10 x 10 cm and thickness ranging from 3 to 15 mm approximately. In the experimental procedure, these proof bodies were irradiated with a Pantak, model HF320 industrial X-ray apparatus. The potentials applied to the respective X-ray tube were: 60kV, 80kV, 120kV and 150kV at a constant current of 1mA. The attenuation responses in function of thickness, for each of the materials analyzed, were used to draw the attenuation and transmission curves. The efficiency of the barite studied concerning the capacity to attenuate X-ray radiation for X-ray beams ranging from 60 to 150 kV indicated.

  2. The logarithmic beam position monitor

    Science.gov (United States)

    Medvedko, Evgeny A.; Smith, Stephen R.

    2000-11-01

    Modern logarithmic amplifiers offer wide dynamic range, high bandwidth, good logarithmic conformance, and low cost making them attractive for beam position measurements. A log-ratio beam position monitor has been designed and built at SLAC for use at the PEP-II B-Factory. An integrated circuit logarithmic amplifier from Analog Devices, the AD8307, recovers the envelope of the 476 MHz harmonic of the beam signal. A log BPM board with two logarithmic and one differential amplifier performs the basic function of forming an output voltage proportional to the difference of the logarithms of the signal amplitudes on opposite electrodes. This voltage is approximately linear with beam position. For this application, we have limited the video bandwidth of the log amps to 50 kHz in order to remove fill pattern dependence. The log BPM board has an interface for testing and simulating beam offsets. The log BPMs were developed for a PEP-II ring protection chassis. Here the log BPMs function to identify dangerous orbit excursions. These excursions are signaled to a system, which can dump the beam. Two such chassis serve to protect the PEP-II rings.

  3. Airy beam optical parametric oscillator.

    Science.gov (United States)

    Aadhi, A; Chaitanya, N Apurv; Jabir, M V; Vaity, Pravin; Singh, R P; Samanta, G K

    2016-05-04

    Airy beam, a non-diffracting waveform, has peculiar properties of self-healing and self-acceleration. Due to such unique properties, the Airy beam finds many applications including curved plasma wave-guiding, micro-particle manipulation, optically mediated particle clearing, long distance communication, and nonlinear frequency conversion. However, many of these applications including laser machining of curved structures, generation of curved plasma channels, guiding of electric discharges in a curved path, study of nonlinear propagation dynamics, and nonlinear interaction demand Airy beam with high power, energy, and wavelength tunability. Till date, none of the Airy beam sources have all these features in a single device. Here, we report a new class of coherent sources based on cubic phase modulation of a singly-resonant optical parametric oscillator (OPO), producing high-power, continuous-wave (cw), tunable radiation in 2-D Airy intensity profile existing over a length >2 m. Based on a MgO-doped periodically poled LiNbO3 crystal pumped at 1064 nm, the Airy beam OPO produces output power more than 8 W, and wavelength tunability across 1.51-1.97 μm. This demonstration gives new direction for the development of sources of arbitrary structured beams at any wavelength, power, and energy in all time scales (cw to femtosecond).

  4. Cluster beam visualization with MCPs

    Energy Technology Data Exchange (ETDEWEB)

    Koehler, Esperanza; Grieser, Silke; Hergemoeller, Ann-Katrin; Taeschner, Alexander; Ortjohann, Hans-Werner; Bonaventura, Daniel; Khoukaz, Alfons [Muenster Univ. (Germany). Inst. fuer Kernphysik

    2013-07-01

    A cluster-jet target will be the first installed internal target for the PANDA experiment at HESR/FAIR. For performance studies a cluster-jet target prototype in complete PANDA geometry was already built up and set successfully into operation at the University of Muenster. At present this target prototype is routinely operated with hydrogen and the use of other materials such as deuterium is also possible. The observation of distinct density structures within the jet beam behind the nozzle and the use of a new tilting system lead to areal target densities of more than 2 x 10{sup 15} atoms/cm{sup 2} at a distance of 2.1 m. The thickness is reproducible, constant in time, and variable over several orders of magnitude. Depending on the experimental program the target beam size and shape is variable. This can be visualized by a new monitoring system based on a Micro Channel Plate (MCP), which allows for a direct observation of an ionized cluster beam. Therefore, the cluster beam is ionized by an electron beam and the signals in the MCP are observed by a phosphor screen in combination with a CCD camera. In this talk the performance of the cluster-jet target and MCP images of the cluster beam are presented and discussed.

  5. Cluster beam investigation with MCPs

    Energy Technology Data Exchange (ETDEWEB)

    Koehler, Esperanza; Bonaventura, Daniel; Grieser, Silke; Hergemoeller, Ann-Katrin; Taeschner, Alexander; Khoukaz, Alfons [Institut fuer Kernphysik, Westfaelische Wilhelms-Universitaet Muenster, 48149 Muenster (Germany)

    2014-07-01

    High intensity cluster-jet beams produced in Laval nozzles represent a very attractive and extremely interesting tool for studies at storage ring experiments, such as PANDA, or for laser-induced particle acceleration. Since the cluster properties vary with increasing number of constituents, it is essential to perform systematic measurements on the target thickness and especially on the cluster masses. For this purpose a monitoring system based on Micro Channel Plates (MCPs) combined with a phosphor screen has been developed and installed at the beam dump of the PANDA prototype cluster-jet target in Muenster. It could be shown that this MCP system allows for a direct observation of an ionised cluster beam. In addition, with this setup the possibility to visualise the vertex zone at the ANKE cluster-jet target at COSY was succesfully demonstrated, where a proton beam with a momentum of 2.09 GeV/c interacted with a hydrogen cluster-jet beam. Furthermore, cluster mass investigations can be performed in conjunction with a retardation field. In this presentation an overview of the MCP detection system, images of the cluster-jet beam and the vertex zone as well as the results of the current cluster mass measurements are presented and discussed.

  6. The ELENA Beam Diagnostics Systems

    CERN Document Server

    Tranquille, G

    2013-01-01

    The Extra Low ENergy Antiproton ring (ELENA) to be built at CERN is aimed at substantially increasing the number of antiprotons to the low energy antiproton physics community. It will be a small machine which will decelerate low intensity beams (<4x107) from 5.3 MeV to 100 keV and will be equipped with an electron cooler to avoid beam losses during the deceleration and to significantly reduce beam phase space at extraction. To measure the beam parameters from the extraction point of the Antiproton Decelerator (AD), through the ELENA ring and all the way to the experiments, many systems will be needed to ensure that the desired beam characteristics are obtained. Particular attention needs to be paid to the performance of the electron cooler which depends on reliable instrumentation in order to efficiently cool the antiprotons. This contribution will present the different monitors that have been proposed to measure the various beam parameters as well as some of the developments going on to further improve th...

  7. A Utopia da Paz Universal

    Directory of Open Access Journals (Sweden)

    Daniel Serrão

    2009-11-01

    Full Text Available Como o Homem atingiu a fase da cultura exterior simbólica em que se encontra actualmente. Apresentaçãosucinta da teoria dos patamares evolutivos de Merlin Donald. O paradigma "popperiano" da investigaçãocientífica moderna: verificar ou falsificar hipóteses. O caso típico da teoria darwiniana da evolução das espéciesvivas. A Bioética como diálogo de saberes em ordem à criação de uma nova sabedoria (wisdom. Apresentação doconceito de Van Rensselaer Potter. O "credo" de Potter e a utopia da paz universal.

  8. Custos da qualidade

    Directory of Open Access Journals (Sweden)

    Gilberto Caetano

    2009-01-01

    Full Text Available Este artigo pretende demonstrar através de uma síntese histórico-conceitual , a evolução da importância do sistema de qualidade, bem como a sua mensuração no processo de tomada de decisão das organizações frente à competitividade estabelecida no contexto da globalização. Assim, procura dar ênfase à ação planejada no sentido de reduzir ou eliminar falhas e defeitos nos vários processos, com vistas a agregar valor ao cliente e ao mesmo tempo reduzir os custos da não-conformidade. Palavras-chave: Custo, qualidade, satisfação, inspeção, controle, requisito, conformidade, não-conformidade, mensuração, processo, prevenção, problema e avaliação. Abstract This article intends to demonstrate through a historical-conceptual synthesis, the evolution of the importance of the quality system, as well as your measurement the process of decision making of the organizations front to the established competitiveness in the context of the globalization. Like this, it tries to give emphasis to the action drifted in the sense of to reduce or to eliminate flaws and defects in the several processes, with views to join value to the customer and at the same time to reduce the costs of the no-conformity. Key-words: Cost, quality, satisfaction, inspection, control, requirement, conformity, no-conformity, measurement, process, prevention, problem and evaluation.

  9. Pioneirismo da associacao brasileira de enfermagem no desenvolvimento da pesquisa: da revista ao centro de pesquisa

    Directory of Open Access Journals (Sweden)

    Lais de Araujo Pereira

    2013-09-01

    Full Text Available O presente estudo tem como objetivo analisar as primeiras iniciativas da Associação Brasileira de Enfermagem para o desenvolvimento da pesquisa em enfermagem. Com um recorte temporal que engloba o período de 1932 a 1971, ano de criação da Revista Brasileira de Enfermagem à criação do Centro de Estudos e Pesquisas, da Associação Brasileira de Enfermagem. As fontes utilizadas foram documentos escritos localizados no Centro de Documentação da Escola de Enfermagem Anna Nery da Universidade Federal do Rio de Janeiro e no Centro de Memória da Associação Brasileira de Enfermagem, além de edições da revista localizadas na Biblioteca Setorial da Pós-Graduação da Escola de Enfermagem Anna Nery. Percebe-se, nesta análise, que os empreendimentos realizados por essa entidade representaram um verdadeiro espaço de investigação e de formação de enfermeiros pesquisadores no Brasil.

  10. Beam-Beam Effects in the Ring-Ring Version of eRHIC

    CERN Document Server

    Shi, Jack; Wang, Dong; Wang, Fuhua

    2005-01-01

    The eRHIC is a proposed electron ring at the RHIC that will provide collisions between a polarized 5-10 GeV electron beam and an ion beam from one of the RHIC rings. In order to achieve proposed high luminosity, large bunch current and small beta-functions at the IP has to be employed. Such measures result in large beam-beam parameters, 0.029 and 0.08 for the electron beam and 0.0065 and 0.0033 for the proton beam in the horizontal and vertical plane, respectively, in the current ZDR design. The beam-beam effect especially the coherent beam-beam effect is therefore one of important issues to the eRHIC. Moreover, the proposed configuration of unequal circumferences of the electron and proton rings could further enhance the coherent beam-beam effect. The beam-beam effect of eRHIC has therefore been studied with a self-consistent beam-beam simulation by using the particle-in-cell method. Beam-beam limits of the electron and proton beam were examined as thresholds of the onset of coherent beam-beam instability. F...

  11. Pensamento da America

    OpenAIRE

    2013-01-01

    Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Filosofia e Ciências Humanas, Programa de Pós-Graduação em História, Florianópolis, 2013. Esta dissertação objetivou investigar a atividade editorial de Rui Ribeiro Couto e Renato Costa Almeida enquanto estes intelectuais estiveram à frente do Pensamento da America, uma publicação mensal vinculada ao A Manhã, jornal porta voz do Estado Novo. Este suplemento panamericano veio a público entre 1941 e 1949, no entanto a...

  12. Propriedades antioxidantes da melatonina

    OpenAIRE

    Teixeira,Adriana

    2003-01-01

    Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências Biológicas. Programa de Pós-Graduação em Neurociências. Foram investigadas as ações da melatonina (MEL) contra a lipoperoxidação (LPO) induzida por hidroxil (OH), ascorbil (Asc) e peroxinitrito (ONOO-) em diversos modelos de membranas como lipossomas de fosfatidilcolina (LipPC) e asolecitina (LipASO), microssomas de cérebro (MicC) e fígado (MicF) e homogeneizado de cérebro (HC); e seu efeito contra enzimas ...

  13. A moral da infidelidade

    Directory of Open Access Journals (Sweden)

    Bundt, Roger

    2007-01-01

    Full Text Available Através das representações da infidelidade conjugal encontradas em três filmes do diretor Adrian Lyne realizados nas décadas de 1980, 1990 e 2000 (Atração Fatal, Proposta Indecente e Infidelidade, busca- se entender as idéias trabalhadas em cada obra, as maneiras de representar a mulher, a família, a relação amorosa e a monogamia, a partir das noções de dever e moral trabalhadas por Gilles Lipovetsky

  14. A moralidade da nanotecnologia

    OpenAIRE

    2012-01-01

    A nanotecnologia é um conjunto formado por saberes, técnicas e práticas que estudam e exploram as novas propriedades dos materiais, quando manipulados em níveis atômicos e moleculares. A possibilidade técnica de organizar e controlar a matéria, desde suas menores dimensões e unidades, pode implicar profundas transformações no processo industrial de produção e ter consequências, moralmente significativas, sobre as inter-relações humanas, a organização da conjuntura social vigente e o próprio f...

  15. Numerical Value Results OF Guassian Beam Focussing

    Institute of Scientific and Technical Information of China (English)

    K.X. He; Alan Chow; Jiada Mo; Wang Zhuo

    2003-01-01

    @@ 1Lens is placed in beam waist We consider the case of a Gaussian beam that is incident at its waist on a thin lens of focal length f.To find the location of the waist of the output beam and the beam radius at that point,we start with the ABCD law.

  16. Electron optics of microlenses with inclined beams

    NARCIS (Netherlands)

    Zhang, Y.; Barth, J.E.; Kruit, P.

    2008-01-01

    For multielectron beam systems with a single electron source, the outside beams need to be collimated before entering the individual microcolumns. As an alternative of the traditional multibeam source design where the broad beam from the source is collimated by a single lens, the broad beam can be f

  17. KTeV beam systems design report

    Energy Technology Data Exchange (ETDEWEB)

    Bocean, V.; Childress, S.; Coleman, R. [and others

    1997-09-01

    The primary and secondary beams for the KTeV experiments E799-II and E832 are discussed. The specifications are presented and justified. The technical details of the implementation of the primary beam transport and stability are detailed. The target, beam dump, and radiation safety issues are discussed. The details of the collimation system for the pair of secondary beams are presented.

  18. BEAM SCRUBBING FOR RHIC POLARIZED PROTON RUN.

    Energy Technology Data Exchange (ETDEWEB)

    ZHANG,S.Y.FISCHER,W.HUANG,H.ROSER,T.

    2004-07-05

    One of the intensity limiting factor of RHIC polarized proton beam is the electron cloud induced pressure rise. A beam scrubbing study shows that with a reasonable period of time of running high intensity 112-bunch proton beam, the pressure rise can be reduced, allowing higher beam intensity.

  19. Quality factor of aberrated gaussian laser beams

    CSIR Research Space (South Africa)

    Mafusire, C

    2010-09-01

    Full Text Available A model is used to calculate the beam quality factor of a laser beam from Zernike coefficients. It is tested by programming aberration coefficients on a laser beam and measuring the beam quality using a Shack-Hartmann wavefront sensor. The two show...

  20. Damage Detection In Laboratory Concrete Beams

    DEFF Research Database (Denmark)

    Brincker, Rune; Andersen, Palle; Kirkegaard, Poul Henning;

    1995-01-01

    : a beam with a typical reinforcement ratio, and a beam with a small reinforcement ratio. The modal properties of the beams were found exciting the beams by a series of pulses and identifying the properties using ARMA and ARMAX models. It was found, that extremely small damages could be detected...

  1. Damage Detection in Laboratory Concrete Beams

    DEFF Research Database (Denmark)

    Brincker, Rune; Andersen, P.; Kirkegaard, Poul Henning;

    : a beam with a typical reinforcement ratio, and a beam with a small reinforcement ratio. The modal properties of the beams were found exciting the beams by a series of pulses and identifying the properties using ARMA and ARMAX models. It was found, that extremely small damages could be detected...

  2. Aspectos moleculares da anemia falciforme

    Directory of Open Access Journals (Sweden)

    Galiza Neto Gentil Claudino de

    2003-01-01

    Full Text Available No presente artigo abordaram-se vários aspectos relacionados à natureza molecular da anemia falciforme, desordem hematológica de caráter hereditário que acomete expressivo número de indivíduos em várias regiões do mundo. As pesquisas realizadas em torno desta patologia da hemácia, ao longo de quase um século, a partir de 1910, cooperaram para a criação de um novo e importante segmento da ciência, denominado biologia molecular. A descoberta dos polimorfismos da mutação (GAT->GTG no gene que codifica a cadeia beta da hemoglobina, originando diferentes haplótipos da doença, permitiu um melhor e mais amplo conhecimento em torno da heterogeneidade clínica nos pacientes falcêmicos. Analisando a hemoglobina na sua estrutura normal e mutante, sua produção e evolução, pode-se ter um entendimento mais completo da fisiopatologia desta doença e da sua complexidade clínica.

  3. Fractais : da geometria à videoarte

    OpenAIRE

    2013-01-01

    A descoberta da geometria fractal é datada de meados do séc. XX. É conhecida como a geometria da natureza já que permite descrever muitos fenómenos naturais que apresentam irregularidades que são impossíveis de descrever através dos princípios da geometria tradicional. O aparecimento de novas tecnologias digitais veio alterar o modo como a arte é encarada. Este trabalho pretende demonstrar possibilidades de integração da geometria fractal e a Teoria do Caos na criação de videoarte, b...

  4. Fisiopatogênese da dor

    Directory of Open Access Journals (Sweden)

    Miguel R. Covian

    1965-09-01

    Full Text Available O estudo da dor é um capítulo do estudo das bases neurofisiológicas da sensação, pois a dor nada mais é que uma sensação de conteúdo desagradável originada por estímulos nocivos. Enquanto a função das outras modalidades sensoriais é informativa ou gnósica, a dor é de proteção. O estudo da fisiología da dor compreende o estudo dos receptores, dos estímulos, das vias, das estruturas do sistema nervoso central que partici- pam da fisiología da dor, da percepção dolorosa e das reações motoras e neurovegetativas. São analisados os receptores e as vias e discutidas sua especificidade, assim como a transmissão da dor rápida e lenta por vias nervosas diferentes até o córtex cerebral. É comentada a influência da atenção na intensidade da percepção dolorosa e, com base em estudos experimentais, é considerado que o circuito retículo-córtico-reticular seja indispensável para a percepção da dor. No tocante à patologia da dor é examinada a insensibilidade congênita à dor, sendo admitida a hipótese de que em algumas sinapses é modificado o esquema de impulsos que darão lugar à sensação dolorosa. É destacado o papel do lobo frontal como parte de um mecanismo pòtenciador que condiciona o sofrimento geral do paciente. A dor referida é explicada pela teoria da "convergência-projeção" de fibras viscerais com fibras cutâneas dolorosas sôbre o mesmo neurônio em algun ponto da via sensitiva. O resultado da hipofisectomia trazendo uma diminuição ou anulação da dor no câncer do seio abre debates em tôrno do papel dos hormônios na percepção dolorosa.

  5. Luminosity Loss due to Beam Distortion and the Beam-Beam Instability

    CERN Document Server

    Wu, Juhao; Raubenheimer, Tor O; Seryi, Andrei; Sramek, Christopher K

    2005-01-01

    In a linear collider, sources of emittance dilution such as transverse wakefields or dispersive errors will couple the vertical phase space to the longitudinal position within the beam (the so-called ‘banana effect'). When the Intersection Point (IP) disruption parameter is large, these beam distortions will be amplified by a single bunch kink instability which will lead to luminosity loss. We study this phenomena both analytically using linear theory and via numerical simulation. In particular, we examine the dependence of the luminosity loss on the wavelength of the beam distortions and the disruption parameter. This analysis may prove useful when optimizing the vertical disruption parameter for luminosity operation with given beam distortions.

  6. Detection of Equipment Faults Before Beam Loss

    CERN Document Server

    Galambos, J.

    2016-01-01

    High-power hadron accelerators have strict limits on fractional beam loss. In principle, once a high-quality beam is set up in an acceptable state, beam loss should remain steady. However, in practice, there are many trips in operational machines, owing to excessive beam loss. This paper deals with monitoring equipment health to identify precursor signals that indicate an issue with equipment that will lead to unacceptable beam loss. To this end, a variety of equipment and beam signal measurements are described. In particular, several operational examples from the Spallation Neutron Source (SNS) of deteriorating equipment functionality leading to beam loss are reported.

  7. Induced focusing and conversion of a Gaussian beam into an elliptic Gaussian beam

    Indian Academy of Sciences (India)

    Manoj Mishra; Swapan Konar

    2005-09-01

    We have presented an investigation of the induced focusing in Kerr media of two laser beams, the pump beam and the probe beam, which could be either Gaussian or elliptic Gaussian or a combination of the two. We have used variational formalism to derive relevant beam-width equations. Among several important findings, the finding that a very week probe beam can be guided and focused when power of both beams are well below their individual threshold for self-focusing, is a noteworthy one. It has been found that induced focusing is not possible for laser beams of any wavelength and beam radius. In case both beams are elliptic Gaussian, we have shown that when power of both beams is above a certain threshold value then the effective radius of both beams collapses and collapse distance depends on power. Moreover, it has been found that induced focusing can be employed to convert a circular Gaussian beam into an elliptic Gaussian beam.

  8. Recent and Past Experiences with Beam-Beam Effects at HERA

    Energy Technology Data Exchange (ETDEWEB)

    Minty, Michiko G

    1999-11-22

    Proton beam stability when in collision with high current electron bunches was of foremost concern during the design stages of the HERA collider[1]. In initial commissioning the beam-beam interaction proved to be a key factor in determining the lifetime of the proton beam. It was quickly ascertained[2] that the proton beam lifetime in collision could be substantially increased by both matching the electron and proton beam sizes ({sigma}) at the interaction points (IPs) and by carefully centering the beams. Presently, proton beam life times of hundreds of hours are routinely observed. In the near future, the accelerators will be upgraded[3] to include new low-{beta} insertions and to allow for yet higher beam currents. Key factors affecting the stability of colliding proton beams will be described as well as recent experiments performed to explore at high electron beam currents new regimes of the proton beam-beam limit at HERA.

  9. Requirements of CLIC Beam Loss Monitoring System

    CERN Document Server

    Sapinski, M; Holzer, EB; Jonker, M; Mallows, S; Otto, T; Welsch, C

    2010-01-01

    The Compact Linear Collider (CLIC) [1] is a proposed multi-TeV linear electron-positron collider being designed by a world-wide collaboration. It is based on a novel twobeam acceleration scheme in which two beams (drive and main beam) are placed in parallel to each other and energy is transferred from the drive beam to the main one. Beam losses on either of them can have catastrophic consequences for the machine, because of high intensity (drive beam) or high energy and small emittance (main beam). In the framework of machine protection, a Beam Loss Monitoring (BLM) system has to be put in place. This paper discusses the requirements for the beam loss system in terms of detector sensitivity, resolution, dynamic range and ability to distinguish losses originating from various sources. The two-beam module where the protection from beam losses is particularly challenging and important, is studied.

  10. Vertical Beam Size Measurement by Streak Camera under Colliding and Single Beam Conditions in KEKB

    CERN Document Server

    Ikeda, Hitomi; Fukuma, Hitoshi; Funakoshi, Yoshihiro; Hiramatsu, Shigenori; Mitsuhashi, Toshiyuki; Ohmi, Kazuhito; Uehara, Sadaharu

    2005-01-01

    Beam behavior of KEKB was studied by measurement of the beam size using a streak camera. Effect of the electron-cloud and the parasitic collision on the vertical beam size was examined in beam collision. We intentionally injected a test bunch of positrons after 2 rf buckets of a bunch to enhance the electron cloud effect and changed electron beam conditions to see the beam-beam effect. The beam size was also measured with a single positron beam and compared with that during collision. The result of the measurement is reported in this paper.

  11. Alight A Beam and Beaming Light -- A Theme With Variations

    Science.gov (United States)

    Chattopadhyay, Swapan

    1997-11-01

    We will explore the physics and technology of interaction of light (coherent and incoherent) with charged particle beams with the generation of novel types of electromagnetic radiation and particle sources in mind. Various configurations will be presented: incoherent scattering of coherent light (laser) from an incoherent particle beam (high temperature), coherent scattering of coherent light (laser) from a `cold' (bunched) beam, amplification of light by a particle beam, femtosecond generation of particle and light beams via `optical slicing' and Thomson/Compton scattering techniques, etc. We will explore the domains of untrashort temporal duration (femtoseconds) as well as of ultrashort wavelengths (x-rays and shorter), with varying degrees of coherence. The relevance of such sources to a few critical areas of research in the natural sciences e.g. ultrafast material, chemical and biological processes, protein folding, x-ray holography, particle phase space cooling and quantum computing will be briefly touched upon. All the processes discussed involve proper interpretation and understanding of coherent states of matter and radiation, as well as the quality and quantity of information and energy embedded in them.

  12. Electron beam direct write: shaped beam overcomes resolution concerns

    Science.gov (United States)

    Stolberg, Ines; Pain, Laurent; Kretz, Johannes; Boettcher, Monika; Doering, Hans-Joachim; Gramss, Juergen; Hahmann, Peter

    2007-02-01

    In semiconductor industry time to market is one of the key success factors. Therefore fast prototyping and low-volume production will become extremely important for developing process technologies that are well ahead of the current technological level. Electron Beam Lithography has been launched for industrial use as a direct write technology for these types of applications. However, limited throughput rates and high tool complexity have been seen as the major concerns restricting the industrial use of this technology. Nowadays this begins to change. Variable Shaped Beam (VSB) writers have been established in Electron Beam Direct Write (EBDW) on Si or GaAs. In the paper semiconductor industry requirements to EBDW will be outlined. Behind this background the Vistec SB3050 lithography system will be reviewed. The achieved resolution enhancement of the VSB system down to the 22nm node exposure capability will be discussed in detail; application examples will be given. Combining EBDW in a Mix and Match technology with optical lithography is one way to utilize the high flexibility advantage of this technology and to overcome existing throughput concerns. However, to some extend a common Single Electron Beam Technology (SBT) will always be limited in throughput. Therefore Vistec's approach of a system that is based on the massive parallelisation of beams (MBT), which was initially pursued in a European Project, will also be discussed.

  13. Tumores cartilaginosos da laringe

    Directory of Open Access Journals (Sweden)

    Thomé Robert

    2001-01-01

    Full Text Available Introdução: Os tumores cartilaginosos da laringe são raros, sendo a cartilagem cricóide a mais acometida. A raridade desses tumores tem como conseqüência experiência limitada e, portanto, o conhecimento a respeito destas neoplasias apresenta pontos obscuros. Objetivo: Apresentar os resultados cirúrgicos bem como o seguimento a longo prazo de 6 pacientes com tumores cartilaginosos da laringe, 4 condrossarcomas de baixa malignidade e 2 condromas. Forma de estudo: Retrospectivo não randomizado. Material e método: Cinco dos tumores acometiam a cartilagem cricóide e 1 a tireóide. Os pacientes foram submetidos a laringectomia parcial (4 e total (2, com seguimento de 6 a 30 anos (média-19,5 anos. Resultados: Nenhum dos pacientes apresentou metástase ou morte relacionada ao tumor. A sobrevida alcançada por 5 anos foi de 100% e a por 20 anos, 67%, sendo a comorbidade responsável por tal decréscimo. Conclusões: Nossos resultados reforçam o conceito de que a laringectomia conservadora seja a modalidade ideal de tratamento, reservando a ressecção total para tumores extensos ou casos de recorrência. Há indícios de que 5 anos pode não ser tempo suficiente para observar recorrência no condrossarcoma de baixo grau de malignidade.

  14. Dos Males da Medida

    Directory of Open Access Journals (Sweden)

    Schwarcz Lilia Moritz

    1997-01-01

    Full Text Available Esse artigo tem como objeto a difícil percepção da "diferença". Tema polêmico, o debate sobre as variedades culturais foi transformado, em meados do século XIX, em uma questão racial e, nesse sentido, vinculado às regularidades da biologia. Tecendo comparações entre os teóricos raciais brasileiros e os impasses mais contemporâneos, sobre a aferição de inteligência e capacidade, esse ensaio pretende provocar. Em pauta estarão as contradições que têm se destacado, mais recentemente, quando se opõem de um lado as etnicidades locais, de outro a tão propalada globalização. Tal qual dois lados de uma mesma moeda, a afirmação de identidades tem se mostrado tão evidente como o próprio estreitamento das relações internacionais. Mudam os termos do debate - de raça, para etnia -, mas, de alguma maneira, continuamos presos a uma lógica positiva de estabelecimento de hierarquias ontológicas.

  15. Os usos da diversidade

    Directory of Open Access Journals (Sweden)

    Clifford Geertz

    1999-05-01

    Full Text Available Resumo Ao discorrer sobre o “Futuro do Etnocentrismo”, este artigo parte da premissa de que a globalização, apesar de ter – em muitos casos – diminuído as diferenças entre povos, não tem amenizado os preconceitos e as formas de discriminação que ocorrem em nome dessas diferenças. Ele resgata a importância do antropólogo neste cenário lembrando que a diversidade cultural faz parte da sociedade complexa, remetendo-se não apenas a grupos étnicos ou nacionais bem delimitados, mas também a diferenças de geração, gênero, sexo e classe, entre outros. Neste contexto, a tolerância passiva de modos distantes de vida assim como a aceitação pragmática de nosso próprio paroquialismo são atitudes não somente intelectualmente desonestas mas também moralmente repreensíveis. É no encontro incômodo de subjetividades variantes na sua própria sociedade que o antropólogo define seu lugar.

  16. A morte da bailarina

    Directory of Open Access Journals (Sweden)

    Nancy Mangabeira Unger

    2010-04-01

    Full Text Available A história do Ocidente pode ser lida de acordo com o sentido da palavra grega hybris: transgressão, presunção, desmesura. Hoje, vivemos o ápice de um percurso marcado pela desejo de tudo dominar. Por sua extrema gravidade, a crise contemporânea nos coloca diante da responsabilidade de questionar a própria dimensão na qual pensamos, e a maneira em que compreendemos nossa identidade enquanto humanos e nosso lugar na totalidade do real.Palavras-chave: civilização ocidental; crise; hybris; questionamento. AbstractThe history of the West can be read according to the meaning of the greek word hybris: transgression, arrogance, loss of measure. We presently live the pinnacle of a course marked by the desire to dominate all beings.  The extreme gravity of  contemporary crisis confronts us with the responsibility of questioning the very dimension in which we think, as well as the manner in which we understand our identity as human beings and our place in the totality of being.Key words: western civilization; crisis; hybris; questioning. 

  17. MTN magnet for the SPS extracted beam.

    CERN Multimedia

    1976-01-01

    This type of dipole magnet was used in the extracted beam lines of the North Area. It shows an opening for three different proton beam lines: a primary extracted proton beam, split by an upstream magnetic beam splitter (see photo 7612017) into three separated beams passes through different parts of its aperture: right, left up, left down. These magnets were designed to be concrete-insulated for radiation resistance. F. Streun stands on the right.

  18. Fractal zone plate beam based optical tweezers

    Science.gov (United States)

    Cheng, Shubo; Zhang, Xinyu; Ma, Wenzhuo; Tao, Shaohua

    2016-01-01

    We demonstrate optical manipulation with an optical beam generated by a fractral zone plate (FZP). The experimental results show that the FZP beam can simultaneously trap multiple particles positioned in different focal planes of the FZP beam, owing to the multiple foci and self-reconstruction property of the FZP beam. The FZP beam can also be used to construct three-dimensional optical tweezers for potential applications. PMID:27678305

  19. Non-paraxial Elliptical Gaussian Beam

    Institute of Scientific and Technical Information of China (English)

    WANG Zhaoying; LIN Qiang; NI Jie

    2001-01-01

    By using the methods of Hertz vector and angular spectrum transormation, the exact solution of non-paraxial elliptical Gaussion beam with general astigmatism based on Maxwell′s equations is obtained. We discussed its propagation characteristics. The results show that the orientation of the elliptical beam spot changes continuously as the beam propagates through isotropic media. Splitting or coupling of beam spots may occur for different initial spot size. This is very different from that of paraxial elliptical Gaussian beam.

  20. Revised data taking schedule with ion beams

    CERN Document Server

    Gazdzicki, Marek; Aduszkiewicz, A; Andrieu, B; Anticic, T; Antoniou, N; Argyriades, J; Asryan, A G; Baatar, B; Blondel, A; Blumer, J; Boldizsar, L; Bravar, A; Brzychczyk, J; Bubak, A; Bunyatov, S A; Choi, K U; Christakoglou, P; Chung, P; Cleymans, J; Derkach, D A; Diakonos, F; Dominik, W; Dumarchez, J; Engel, R; Ereditato, A; Feofilov, G A; Fodor, Z; Ferrero, A; Gazdzicki, M; Golubeva, M; Grebieszkow, K; Grzeszczuk, A; Guber, F; Hasegawa, T; Haungs, A; Igolkin, S; Ivanov, A S; Ivashkin, A; Kadija, K; Katrynska, N; Kielczewska, D; Kikola, D; Kisiel, J; Kobayashi, T; Kolesnikov, V I; Kolev, D; Kolevatov, R S; Kondratiev, V P; Kowalski, S; Kurepin, A; Lacey, R; Laszlo, A; Lyubushkin, V V; Majka, Z; I Malakhov, A; Marchionni, A; Marcinek, A; Maris, I; Matveev, V; Melkumov, G L; Meregaglia, A; Messina, M; Mijakowski, P; Mitrovski, M; Montaruli, T; Mrówczynski, St; Murphy, S; Nakadaira, T; Naumenko, P A; Nikolic, V; Nishikawa, K; Palczewski, T; Pálla, G; Panagiotou, A D; Peryt, W; Planeta, R; Pluta, J; Popov, B A; Posiadala, M; Przewlocki, P; Rauch, W; Ravonel, M; Renfordt, R; Röhrich, D; Rondio, E; Rossi, B; Roth, M; Rubbia, A; Rybczynski, M; Sadovskii, A; Sakashita, K; Schuster, T; Sekiguchi, T; Seyboth, P; Shibata, M; Sissakian, A N; Skrzypczak, E; Slodkowski, M; Sorin, A S; Staszel, P; Stefanek, G; Stepaniak, J; Strabel, C; Ströbele, H; Susa, T; Szentpétery, I; Szuba, M; Tada, M; Taranenko, A; Tsenov, R; Ulrich, R; Unger, M; Vassiliou, M; Vechernin, V V; Vesztergombi, G; Wlodarczyk, Z; Wojtaszek, A; Zipper, W; CERN. Geneva. SPS and PS Experiments Committee; SPSC

    2009-01-01

    This document presents the revised data taking schedule of NA61 with ion beams. The revision takes into account limitations due to the new LHC schedule as well as final results concerning the physics performance with secondary ion beams. It is proposed to take data with primary Ar and Xe beams in 2012 and 2014, respectively, and to test and use for physics a secondary B beam from primary Pb beam fragmentation in 2010, 2011 and 2013.

  1. Beam Impedance Studies of the PS Beam Gas Ionization Monitor

    CERN Document Server

    Avgidis, Fotios

    2016-01-01

    The Beam Gas Ionization monitor (BGI) is a device for continuous beam size monitoring that is intended to be installed in the CERN Proton Synchrotron (PS) during the extended year-end technical stop from December 2016 to April 2017. With the objective of determining the impedance contribution of the BGI vacuum chamber to the overall beam impedance, we report on RF measurements on the device in a laboratory frame, measurement data analysis, and RF simulations of the structure under investigation. For the impedance contribution characterization of the BGI, the following approach has been followed: First, the EM fields inside a simplified BGI model that doesn’t include any of the internal components of the vacuum chamber have been simulated. RF measurements have been performed on the same empty structure showing great agreement between measurement and simulation and thus verifying the validity of the model. Second, simulations have been executed on a fully assembled BGI model that includes all the internal ele...

  2. Laguerre-Gauss beams versus Bessel beams showdown: peer comparison.

    Science.gov (United States)

    Mendoza-Hernández, Job; Arroyo-Carrasco, Maximino Luis; Iturbe-Castillo, Marcelo David; Chávez-Cerda, Sabino

    2015-08-15

    We present for the first time a comparison under similar circumstances between Laguerre-Gauss beams (LGBs) and Bessel beams (BB), and show that the former can be a better option for many applications in which BBs are currently used. By solving the Laguerre-Gauss differential equation in the asymptotic limit of a large radial index, we find the parameters to perform a peer comparison, showing that LGBs can propagate quasi-nondiffracting beams within the same region of space where the corresponding BBs do. We also demonstrate that LGBs, which have the property of self-healing, are more robust in the sense that they can propagate further than BBs under similar initial conditions.

  3. Beam based measurement of beam position monitor electrode gains

    Directory of Open Access Journals (Sweden)

    D. L. Rubin

    2010-09-01

    Full Text Available Low emittance tuning at the Cornell Electron Storage Ring (CESR test accelerator depends on precision measurement of vertical dispersion and transverse coupling. The CESR beam position monitors (BPMs consist of four button electrodes, instrumented with electronics that allow acquisition of turn-by-turn data. The response to the beam will vary among the four electrodes due to differences in electronic gain and/or misalignment. This variation in the response of the BPM electrodes will couple real horizontal offset to apparent vertical position, and introduce spurious measurements of coupling and vertical dispersion. To alleviate this systematic effect, a beam based technique to measure the relative response of the four electrodes has been developed. With typical CESR parameters, simulations show that turn-by-turn BPM data can be used to determine electrode gains to within ∼0.1%.

  4. Whole toxicity removal for industrial and domestic effluents treated with electron beam radiation, evaluated with Vibrio fischeri, Daphnia similis and Poecilia reticulata; Reducao da toxicidade aguda de efluentes industriais e domesticos tratados por irradiacao com feixe de eletrons, avaliada com as especies Vibrio fischeri, Daphnia similis and Poecilia reticulata

    Energy Technology Data Exchange (ETDEWEB)

    Borrely, Sueli Ivone

    2001-07-01

    Several studies have been performed in order to apply ionizing radiation to treat real complexes effluents from different sources, at IPEN. This paper shows the results of such kind of application devoted to influents and effluents from Suzano Wastewater Treatment Plant, Sao Paulo, Suzano WTP, from SABESP. The purpose of the work was to evaluate the radiation technology according to ecotoxicological aspects. The evaluation was carried out on the toxicity bases which included three sampling sites as follows: complex industrial effluents; domestic sewage mixed to the industrial discharge (GM) and final secondary effluent. The tested-organisms for toxicity evaluation were: the marine bacteria Vibrio fischeri, the microcrustacean Daphnia similis and the guppy Poecilia reticulata. The fish tests were applied only for secondary final effluents. The results demonstrated the original acute toxicity levels as well as the efficiency of electron beam for its reduction. An important acute toxicity removal was achieved: from 75% up to 95% with 50 kGy (UNA), 20 kGy (GM) and 5.0 kGy for the final effluent. The toxicity removal was a consequence of several organic solvents decomposed by radiation and acute toxicity reduction was about 95%. When the toxicity was evaluated for fish the radiation efficiency reached from 40% to 60%. The hypothesis tests showed a statistical significant removal in the developed studies condition. No residual hydrogen peroxide was found after 5.0 kGy was applied to final effluent. (author)

  5. Comparison between dose calculation in XiO Registered-Sign and dosimetric measurements in virtual wedge photon beams; Comparacao entre o calculo da dose no XiO Registered-Sign e medidas dosimetricas em feixes de fotons com filtro virtual

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, Laila G.; Amaral, Leonardo L.; Oliveira, Harley F., E-mail: lailagalmeida@gmail.com [Universidade de Sao Paulo (HCFMRP/USP), Ribeirao Preto, SP (Brazil). Hospital das Clinicas. Servico de Radioterapia; Maia, Ana F. [Universidade Federal de Sergipe (UFS), Sao Cristovao (Sweden), (Brasil) Departamento de Fisica

    2012-08-15

    The virtual wedge is useful tool in the radiation treatment planning since it has series of advantages over the hard wedge. Quality control tests ensure correct performance of the planning done in treatment planning systems (TPS). This study aimed to compare doses calculated by TPS and doses measured by ionization chamber (CI) and an ionization chambers array in virtual wedge photon beams of 6 MV. Measures carried out in Primus linear accelerator with a solid water phantom and dosimeter positioned at 10 cm depth with gantry at 0 Degree-Sign in many fields sizes and angles in the virtual wedge. Measurements on the central axis used as dosimeter an IC and on off-axis used an IC array. The simulation in CMS-XiO used the CT images of the phantom in the same configuration of the irradiation. Maximum and minimum values of the percentage differences between the doses provided by TPS and measurements with ionization chamber on the central axis were 1.43 and -0.10%, respectively, with average percentage difference of 0.08% and confidence limit of {Delta}=1.72%. In the region off-axis, the average percentage difference was 0.04%, with a maximum of 1.9%, minimum of 0% and confidence limit of {Delta}=1.91%. All values for dose percentage differences were below 2% and lower confidence limit of 3% are thus, according to the recommendations of the Technical Report Series - TRS-430. (author)

  6. Explorando Sistemas Hamiltonianos II: A Natureza de Pontos de Equilibrio Degenerados

    CERN Document Server

    Monerat, G A; Oliveira-Neto, G; Nogueira, P H A S; Assumpcao, A R P; de Oliveira, T M G

    2007-01-01

    Neste segundo artigo sobre sistemas Hamiltonianos, apresentamos o metodo da explosao para a determinacao da natureza de pontos fixos (pontos de equilibrio degenerados. Aplicamos o metodo a dois modelos hamiltonianos com um e dois graus de liberdade, respectivamente. Primeiramente, analisamos um sistema formado por um pendulo simples submetido a um torque externo constante T. Em seguida, consideramos um sistema formado por um pendulo duplo com segmentos de comprimentos e massas iguais, tambem submetidos a torques externos constantes e nao nulos. A presenca de pontos de equilibrio degenerados nos casos dos pendulos simples e duplo ocorre para certos valores dos torques externos. In this second article on Hamiltonian systems, we present the blow-up method for the determination of the nature of degenerate fixed points (equilibrium points). We apply the method to two hamiltonian models with one and two degrees of freedom, respectively. Firstly we study a system formed by a simple pendulum submitted to a constant e...

  7. Beam Measurements in Storage Rings

    Science.gov (United States)

    Hofmann, Albert

    1996-05-01

    Beam measurements in storage rings are made to diagnose performance limitations and to gain knowledge of the beam behavior in view of improvements and to the benefit for other machines. In beam optics the measurement of the orbit or the trajectory with beam position monitors distributed around the ring reveals deflection errors. The overall focusing is checked by measuring the betatron frequency (tune) using a pulse or continuous excitation of the oscillation. Observing this oscillation with all the beam position monitors around the ring the beta function and the betatron phase advance are obtained. This measurement done for different momenta, i.e. RF-frequencies, gives the local chromaticity and its correction. The tune dependence on quadrupole strength gives the value of the local beta function. Synchrotron radiation is a powerful diagnostics tool and can give the beam cross section. Beam instabilities are investigated with similar methods. The growth or damping rates and frequencies of betatron and synchrotron oscillations, observed as a function of intensity, give a convolution of the resistive and reactive part of the transverse and longitudinal impedance with the spectrum of the oscillation mode. Coupled bunch instabilities are caused by narrow band impedances at particular frequencies while single traversal effects, including energy loss and bunch lengthening, are due to a broad band impedance. A model of the impedance can be constructed from such measurements done with different bunch lengths, tunes and other parameters. In some cases the element causing an instability can be identified. The dependence of the orbit and phase advance around the ring on intensity can give the location of impedances. To probe the impedance at very high frequencies the effects on very short bunches or the energy loss of a continuous beam due to its Schottky noise are measured. The beam energy, usually known from magnetic measurements, can be obtained directly with high

  8. Applications of electron lenses: scraping of high-power beams, beam-beam compensation, and nonlinear optics

    Energy Technology Data Exchange (ETDEWEB)

    Stancari, Giulio

    2014-09-11

    Electron lenses are pulsed, magnetically confined electron beams whose current-density profile is shaped to obtain the desired effect on the circulating beam. Electron lenses were used in the Fermilab Tevatron collider for bunch-by-bunch compensation of long-range beam-beam tune shifts, for removal of uncaptured particles in the abort gap, for preliminary experiments on head-on beam-beam compensation, and for the demonstration of halo scraping with hollow electron beams. Electron lenses for beam-beam compensation are being commissioned in the Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Laboratory (BNL). Hollow electron beam collimation and halo control were studied as an option to complement the collimation system for the upgrades of the Large Hadron Collider (LHC) at CERN; a conceptual design was recently completed. Because of their electric charge and the absence of materials close to the proton beam, electron lenses may also provide an alternative to wires for long-range beam-beam compensation in LHC luminosity upgrade scenarios with small crossing angles. At Fermilab, we are planning to install an electron lens in the Integrable Optics Test Accelerator (IOTA, a 40-m ring for 150-MeV electrons) as one of the proof-of-principle implementations of nonlinear integrable optics to achieve large tune spreads and more stable beams without loss of dynamic aperture.

  9. Fusion at the barrier with light radioactive ion beams

    CERN Document Server

    Signorini, C

    2001-01-01

    The experimental results recently obtained for fusion reactions at energies close to the Coulomb barrier with light radioactive (loosely bound) beams are reviewed and critically discussed. There have been two conflicting views on the effect of the loose binding of the projectile on the fusion cross section. On the one hand one expects an enhancement of the fusion cross section due to the loose binding while, on the other hand, the easy breakup of the projectile is expected to inhibit the fusion cross section. We critically discuss these two aspects of loose binding by comparing the experimental results for a number of radioactive beams. The data for sup 1 sup 7 F (where the last neutron binding energy S sub n =0.601 MeV), neither show breakup effects nor enhancement when compared with the fusion of the nucleus sup 1 sup 9 F. The data for a sup 6 He beam (S sub 2 sub n =0.975 MeV) show enhancement, very strong in one case, and the strong breakup (BU)+transfer cross section may be related to this. The fusion da...

  10. Active beam spectroscopy for ITER

    Energy Technology Data Exchange (ETDEWEB)

    Von Hellermann, M.; Giroud, C.; Jaspers, R. [Association Euratom-Fom, FOM Institute for Plasma Physics Rijnhuizen, Trilateral Euregio Cluster (Netherlands); Hawkes, N.C.; Mullane, M.O.; Zastrow, K.D. [Euratom/UKAEA Fusion Association, Culham Science Centre, Abingdon (United Kingdom); Krasilnikov, A.; Tugarinov, S. [SRC RF TRINITI, Troitsk, Moscow region (Russian Federation); Lotte, P. [Association Euratom-CEA Cadarache, 13 - Saint-Paul-lez-Durance (France). Dept. de Recherches sur la Fusion Controlee; McKee, G. [Wisconsin Univ., Madison, WI (United States); Malaquias, A. [Associacao EURATOM/IST, Instituto Superior Tecnico, Lisboa (Portugal); Rachlew, E. [Kungliga Tekniska Hoegskolan (KTH), Stockholm(Sweden)

    2003-07-01

    The latest status of 'Active Beam' related spectroscopy aspects as part of the ITER diagnostic scenario is presented. A key issue of the proposed scheme is based on the concept that in order to achieve the ultimate goal of global data consistency, all particles involved, that is, intrinsic and seeded impurity ions as well as helium ash ions and bulk plasma ions and also the plasma background data (e.g. magnetic and electric fields, electron density and temperature profiles) need to be addressed. A further sensible step in this direction is the decision of exploiting both a dedicated low-energy, low-power diagnostic beam (DNB, 2.2 MW 100 keV/amu) as well as the high-power, high-energy heating beams (HNB, 17 MW 500 keV/amu) for maximum diagnostic information. The authors report some new aspects referring to the use of DNB for motional Stark effect (MSE) where the main idea is to treat both beams (HNB and DNB) as potential diagnostic tools with complementary roles. The equatorial ports for the DNB promise excellent spatial resolution, however, the angles are less favourable for a polarimetric MSE exploitation. HNB can be used as probe beam for diagnosing slowing-down fusion alpha with a birth energy of 3,5 MeV.

  11. Electron beam pumped semiconductor laser

    Science.gov (United States)

    Hug, William F. (Inventor); Reid, Ray D. (Inventor)

    2009-01-01

    Electron-beam-pumped semiconductor ultra-violet optical sources (ESUVOSs) are disclosed that use ballistic electron pumped wide bandgap semiconductor materials. The sources may produce incoherent radiation and take the form of electron-beam-pumped light emitting triodes (ELETs). The sources may produce coherent radiation and take the form of electron-beam-pumped laser triodes (ELTs). The ELTs may take the form of electron-beam-pumped vertical cavity surface emitting lasers (EVCSEL) or edge emitting electron-beam-pumped lasers (EEELs). The semiconductor medium may take the form of an aluminum gallium nitride alloy that has a mole fraction of aluminum selected to give a desired emission wavelength, diamond, or diamond-like carbon (DLC). The sources may be produced from discrete components that are assembled after their individual formation or they may be produced using batch MEMS-type or semiconductor-type processing techniques to build them up in a whole or partial monolithic manner, or combination thereof.

  12. The ATLAS beam conditions monitor

    CERN Document Server

    Mikuz, M; Dolenc, I; Kagan, H; Kramberger, G; Frais-Kölbl, H; Gorisek, A; Griesmayer, E; Mandic, I; Pernegger, H; Trischuk, W; Weilhammer, P; Zavrtanik, M

    2006-01-01

    The ATLAS beam conditions monitor is being developed as a stand-alone device allowing to separate LHC collisions from background events induced either on beam gas or by beam accidents, for example scraping at the collimators upstream the spectrometer. This separation can be achieved by timing coincidences between two stations placed symmetric around the interaction point. The 25 ns repetition of collisions poses very stringent requirements on the timing resolution. The optimum separation between collision and background events is just 12.5 ns implying a distance of 3.8 m between the two stations. 3 ns wide pulses are required with 1 ns rise time and baseline restoration in 10 ns. Combined with the radiation field of 10/sup 15/ cm/sup -2/ in 10 years of LHC operation only diamond detectors are considered suitable for this task. pCVD diamond pad detectors of 1 cm/sup 2/ and around 500 mum thickness were assembled with a two-stage RF current amplifier and tested in proton beam at MGH, Boston and SPS pion beam at...

  13. Low voltage electron beam accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Ochi, Masafumi [Iwasaki Electric Co., Ltd., Tokyo (Japan)

    2003-02-01

    Widely used electron accelerators in industries are the electron beams with acceleration voltage at 300 kV or less. The typical examples are shown on manufactures in Japan, equipment configuration, operation, determination of process parameters, and basic maintenance requirement of the electron beam processors. New electron beam processors with acceleration voltage around 100 kV were introduced maintaining the relatively high dose speed capability of around 10,000 kGy x mpm at production by ESI (Energy Science Inc. USA, Iwasaki Electric Group). The application field like printing and coating for packaging requires treating thickness of 30 micron or less. It does not require high voltage over 110 kV. Also recently developed is a miniature bulb type electron beam tube with energy less than 60 kV. The new application area for this new electron beam tube is being searched. The drive force of this technology to spread in the industries would be further development of new application, process and market as well as the price reduction of the equipment, upon which further acknowledgement and acceptance of the technology to societies and industries would entirely depend. (Y. Tanaka)

  14. Generalized beam quality factor of aberrated truncated Gaussian laser beams

    CSIR Research Space (South Africa)

    Mafusire, C

    2011-07-01

    Full Text Available factor of aberrated truncated Gaussian laser beams Cosmas Mafusire1,2 and Andrew Forbes1,2,* 1Council for Scientific and Industrial Research National Laser Centre, P.O. Box 395, Pretoria, South Africa 2School of Physics, University of Kwa... is verified experimentally by implementing aberrations as digital holograms in the laboratory. ? 2011 Optical Society of America OCIS codes: 140.3295, 080.1005, 120.5050. 1. INTRODUCTION The laser beam quality factor (M2) is a useful parameter...

  15. Electron beam ion source and electron beam ion trap (invited).

    Science.gov (United States)

    Becker, Reinard; Kester, Oliver

    2010-02-01

    The electron beam ion source (EBIS) and its trap variant [electron beam ion trap (EBIT)] celebrated their 40th and 20th anniversary, respectively, at the EBIS/T Symposium 2007 in Heidelberg. These technologically challenging sources of highly charged ions have seen a broad development in many countries over the last decades. In contrast to most other ion sources the recipe of improvement was not "sorcery" but a clear understanding of the physical laws and obeying the technological constraints. This review will report important achievements of the past as well as promising developments in the future.

  16. Electron beam ion source and electron beam ion trap (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Becker, Reinard [Scientific Software Service, Kapellenweg 2a, D-63571 Gelnhausen (Germany); Kester, Oliver [National Superconducting Cyclotron Laboratory, Michigan State University, East Lansing, Michigan 48824 (United States)

    2010-02-15

    The electron beam ion source (EBIS) and its trap variant [electron beam ion trap (EBIT)] celebrated their 40th and 20th anniversary, respectively, at the EBIS/T Symposium 2007 in Heidelberg. These technologically challenging sources of highly charged ions have seen a broad development in many countries over the last decades. In contrast to most other ion sources the recipe of improvement was not ''sorcery'' but a clear understanding of the physical laws and obeying the technological constraints. This review will report important achievements of the past as well as promising developments in the future.

  17. Generate Uniform Transverse Distributed Electron Beam along a Beam Line

    CERN Document Server

    Jiao, Y

    2015-01-01

    It has been reported that transverse distribution shaping can help to further enhance the energy extraction efficiency in a terawatt, tapered X-ray free-electron laser. Thus, methods of creating and keeping almost uniform transverse distributed (UTD) beam within undulators are required. This study shows that a UTD electron beam can be generated within evenly distributed drift sections where undulators can be placed, by means of octupoles and particular optics. A concrete design is presented, and numerical simulations are done to verify the proposed method.

  18. Rotating Dual-Wire Beam Profile Monitor Optimized for Use in Merged-Beams Experiments

    Energy Technology Data Exchange (ETDEWEB)

    Seely, D. G. [Albion College; Bruhns, H. [Columbia University; Savin, D. W. [Columbia University; Kvale, Thomas Jay [University of Toledo, Toledo, OH; Galutschek, Ernst [ORNL; Aliabadi, Habib [ORNL; Havener, Charles C [ORNL

    2008-01-01

    A rotating dual-wire beam proile monitor based upon a modified National Electrostatics Corporation Model BPM80 beam profile monitor is described. The device can measure beam profiles in two perpendicular directions (horizontal and vertical) in each of two pseudoplanes that are situated along the beam axis and are separated by a distance of 6.0 cm. The output signal from the device is analyzed in real time to yield horizontal and vertical beam profiles and to calculate the divergence of a particle beam that traverses the device. This set-up is well-suited for merged-beams experiments where one beam is tuned to saved profiles from a second beam in order to minimize the merge angle and beam divergences while maximizing the beam-beam overlaps.

  19. Rotating dual-wire beam profile monitor optimized for use in merged-beams experiments

    Energy Technology Data Exchange (ETDEWEB)

    Seely, D.G. [Department of Physics, Albion College, Albion, MI 49224-1831 (United States)], E-mail: dseely@albion.edu; Bruhns, H.; Savin, D.W. [Columbia Astrophysics Laboratory, Columbia University, New York, NY 10027-6606 (United States); Kvale, T.J. [Department of Physics and Astronomy, University of Toledo, Toledo, OH 43606-3390 (United States); Galutschek, E.; Aliabadi, H.; Havener, C.C. [Physics Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831-6372 (United States)

    2008-01-21

    A rotating dual-wire beam profile monitor based upon a National Electrostatics Corporation Model BPM80 beam profile monitor is described. The device can measure beam profiles in two perpendicular directions (horizontal and vertical) in each of two pseudoplanes that are situated along the beam axis and are separated by a distance of 5.4 cm. The output signal from the device is analyzed in real time to yield horizontal and vertical beam profiles and to calculate the divergence of a particle beam that traverses the device. This set-up is well-suited for merged-beams experiments where one beam is tuned to saved profiles from a second beam in order to minimize the merge angle and beam divergences while maximizing the beam-beam overlaps.

  20. Fisiologia da caquexia

    OpenAIRE

    Gonçalves, Catarina Vicente

    2014-01-01

    Dissertação para obtenção do grau de Mestre no Instituto Superior de Ciências da Saúde Egas Moniz A caquexia é uma síndrome de desnutrição multifatorial que se caracteriza por uma perda de peso e perda de massa muscular. Esta síndrome parte de uma doença subjacente e pode estar presente em várias doenças crónicas como por exemplo HIV, doença renal crónica, DPOC, doença hepática crónica, insuficiência cardíaca congénita e cancro. Com este trabalho, pretendeu-se entender a definição de ca...

  1. Em favor da talassografia

    Directory of Open Access Journals (Sweden)

    Jean-Louis Boudou

    2001-01-01

    Full Text Available A Talassografia (“descrição do mar” interessa-sepelos impactos físicos, biológicos, ecológicos... culturais da violenta antropização dos ambientes costeiros (oceânicos e continentais, caracterizados pelaexigüidade, vulnerabilidade, fragilidade e plasticidade. Como o Brasil é um “país marítimo”, os geó-grafos (os talassógrafos brasileiros são convidadosa intensificar suas pesquisas nas áreas costeiras e acriar novas estruturas para divulgá-las: Revista, Encontros, Associação, Pós-Graduação... tudo em prolda talassografia.

  2. Fisiologia da caquexia

    OpenAIRE

    Gonçalves, Catarina Vicente

    2014-01-01

    Dissertação para obtenção do grau de Mestre no Instituto Superior de Ciências da Saúde Egas Moniz A caquexia é uma síndrome de desnutrição multifatorial que se caracteriza por uma perda de peso e perda de massa muscular. Esta síndrome parte de uma doença subjacente e pode estar presente em várias doenças crónicas como por exemplo HIV, doença renal crónica, DPOC, doença hepática crónica, insuficiência cardíaca congénita e cancro. Com este trabalho, pretendeu-se entender a definição de ca...

  3. Berengario da Carpi.

    Science.gov (United States)

    De Santo, N G; Bisaccia, C; De Santo, L S; De Santo, R M; Di Leo, V A; Papalia, T; Cirillo, M; Touwaide, A

    1999-01-01

    Berengario da Carpi was magister of anatomy and surgery at the University of Bologna from 1502 to 1527. Eustachio and Falloppia defined him as 'the restaurator of anatomy'. He was a great surgeon, anatomist and physician of illustrious patients including Lorenzo II dei Medici, Giovanni dalle Bande Nere, Galeazzo Pallavicini, Cardinal Colonna, and Alessandro Soderini. He had strong links to the intellectuals of his time (Forni, Bonamici, Manuzio, Pomponazzi) as well as with the Medici family. He was respected by the Popes Julius II, Leo X and Clement VII. His main contributions are the Isogogae Breves, De Fractura calvae sive cranei, and the illustrated Commentaria on the Anatomy of Mondino de Liucci, a textbook utilized for more than 200 years, which Berengario aimed to restore to its initial text. The Commentaria constitutes the material for the last part of this paper which concludes with a personal translation of some passages on 'The kidney', where the author gives poignant examples of experimental ingenuity.

  4. Physics opportunities with meson beams

    Energy Technology Data Exchange (ETDEWEB)

    Briscoe, William J.; Doering, Michael; Haberzettl, Helmut; Strakovsky, Igor I. [The George Washington University, Washington, DC (United States); Manley, D.M. [Kent State University, Kent, OH (United States); Naruki, Megumi [Kyoto University, Kyoto (Japan); Swanson, Eric S. [University of Pittsburgh, Pittsburgh, PA (United States)

    2015-10-15

    Over the past two decades, meson photo- and electroproduction data of unprecedented quality and quantity have been measured at electromagnetic facilities worldwide. By contrast, the meson-beam data for the same hadronic final states are mostly outdated and largely of poor quality, or even non-existent, and thus provide inadequate input to help interpret, analyze, and exploit the full potential of the new electromagnetic data. To reap the full benefit of the high-precision electromagnetic data, new high-statistics data from measurements with meson beams, with good angle and energy coverage for a wide range of reactions, are critically needed to advance our knowledge in baryon and meson spectroscopy and other related areas of hadron physics. To address this situation, a state-of-the-art meson-beam facility needs to be constructed. The present paper summarizes unresolved issues in hadron physics and outlines the vast opportunities and advances that only become possible with such a facility. (orig.)

  5. Beam purification by photodetachment (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Y.; Beene, J. R.; Galindo-Uribarri, A.; Havener, C. C. [Physics Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831 (United States); Andersson, P.; Forstner, O. [Vera Laboratory, Fakultaet fuer Physik, Universitaet Wien, AT-1090 Wien (Austria); Gottwald, T.; Wendt, K. [Institute of Physics, Johannes Gutenberg-University Mainz, D-55099 Mainz (Germany); Hanstorp, D.; Lindahl, A. O. [Department of Physics, University of Gothenburg, SE-412 96 Gothenburg (Sweden)

    2012-02-15

    Ion beam purity is of crucial importance to many basic and applied studies in nuclear science. Selective photodetachment has been proposed to suppress unwanted species in negative ion beams while preserving the intensity of the species of interest. A highly efficient technique based on photodetachment in a gas-filled radio frequency quadrupole ion cooler has been demonstrated. In off-line experiments with stable ions, up to 10{sup 4} times suppression of the isobar contaminants in a number of interesting radioactive negative ion beams has been demonstrated. For selected species, this technique promises new experimental possibilities in studies on exotic nuclei, accelerator mass spectrometry, and fundamental properties of negative atomic and molecular ions.

  6. Edge imaging in intense beams

    Directory of Open Access Journals (Sweden)

    S. Bernal

    2002-06-01

    Full Text Available The appearance of rings of charge observed near the edge of beams from high-perveance guns is described with a simple ray tracing technique inspired by the particle-core model. We illustrate the technique, which has no analog in light optics, with examples from experiments employing solenoid focusing of an electron beam. The rings of charge result from the combined effects of external focusing and space-charge forces acting on paraxial fringe particles with relatively large initial transverse velocities. The model is independent of the physical mechanisms responsible for the fringe particles. Furthermore, the focal length for edge imaging in a uniform focusing channel is derived using a linearized trajectory equation for the motion of fringe particles. Counterintuitively, the focal length decreases as the beam current increases.

  7. Beam Cleaning and Collimation Systems

    CERN Document Server

    Redaelli, S

    2016-01-01

    Collimation systems in particle accelerators are designed to dispose of unavoidable losses safely and efficiently during beam operation. Different roles are required for different types of accelerator. The present state of the art in beam collimation is exemplified in high-intensity, high-energy superconducting hadron colliders, like the CERN Large Hadron Collider (LHC), where stored beam energies reach levels up to several orders of magnitude higher than the tiny energies required to quench cold magnets. Collimation systems are essential systems for the daily operation of these modern machines. In this document, the design of a multistage collimation system is reviewed, taking the LHC as an example case study. In this case, unprecedented cleaning performance has been achieved, together with a system complexity comparable to no other accelerator. Aspects related to collimator design and operational challenges of large collimation systems are also addressed.

  8. Preservation of beam loss induced quenches, beam lifetime and beam loss measurements with the HERAp beam-loss-monitor system

    Science.gov (United States)

    Wittenburg, Kay

    1994-06-01

    The beam-loss-monitors (BLMs) in the HERA-proton-ring (HERAp) must fulfill the following requirements: They have to measure losses sensitive and fast enough to prevent the superconducting magnets from beam loss induced quenching; the dynamic range of the monitors must exceed several decades in order to measure losses during beam lifetimes of hundreds of hours as well as the much stronger losses that may quench superconducting magnets; they have to be insensitive to the synchrotron radiation of the adjacent electron-ring (HERAe); and their radiation hardness must allow a monitor-lifetime of a few years of HERA operation. These requirements are well satisfied by the HERAp-BLM-System.

  9. Mycosis fungoides. Electron beam therapy.

    Science.gov (United States)

    Spittle, M F

    1977-01-01

    The most effective treatment of late mycosis fungoides is total skin electron beam therapy. The beam at the Hammersmith Hospital in London has been adapted to treat these patients. Patients with advanced disease who have failed more conservative methods of treatment are irradiated. The electron beam is modified by the use of carbon and copper scatterers to produce an 80 percent depth dose at 5.5, 8 and 11.5 millimeters below the skin surface. The dose achieved in most patients is between 1500 rads and 2600 rads given in 10 to 13 treatments over 5-7 weeks. Recently the higher dose range has been employed and lithium flouride studies have shown that giving these doses from each of 4 fields, the dose achieved on the skin is approximately twice the given dose. The management of patients and the effects of treatment are discussed.

  10. Physics Opportunities with Meson Beams

    CERN Document Server

    Briscoe, William J; Haberzettl, Helmut; Manley, D Mark; Naruki, Megumi; Strakovsky, Igor I; Swanson, Eric S

    2015-01-01

    Over the past two decades, meson photo- and electro-production data of unprecedented quality and quantity have been measured at electromagnetic facilities worldwide. By contrast, the meson-beam data for the same hadronic final states are mostly outdated and largely of poor quality, or even nonexistent, and thus provide inadequate input to help interpret, analyze, and exploit the full potential of the new electromagnetic data. To reap the full benefit of the high-precision electromagnetic data, new high-statistics data from measurements with meson beams, with good angle and energy coverage for a wide range of reactions, are critically needed to advance our knowledge in baryon and meson spectroscopy and other related areas of hadron physics. To address this situation, a state of-the-art meson-beam facility needs to be constructed. The present paper summarizes unresolved issues in hadron physics and outlines the vast opportunities and advances that only become possible with such a facility.

  11. Divergence of optical vortex beams

    CERN Document Server

    Reddy, Salla Gangi; Prabhakar, Shashi; Anwar, Ali; Banerji, J; Singh, R P

    2015-01-01

    We show, both theoretically and experimentally, that the propagation of optical vortices in free space can be analysed by using the width ($w(z)$) of the host Gaussian beam and the inner and outer radii of the vortex beam at the source plane ($z=0$) as defined in \\textit{Optics Letters \\textbf{39,} 4364-4367 (2014)}. We also studied the divergence of vortex beams, considered as the rate of change of inner or outer radius with the propagation distance, and found that it varies with the order in the same way as that of the inner and outer radii at zero propagation distance. These results may be useful in designing optical fibers for orbital angular momentum modes that play a crucial role in quantum communication.

  12. Uniform versus Gaussian Beams: A Comparison of the Effects of Diffraction, Obscuration, and Aberations.

    Science.gov (United States)

    1985-12-16

    beams D0 FOR 1473 UNCLASSIFIED SECURITY CLASSIFICATION OF THIS PAGE (Wen Dese Entered UNCLASSIFIED I[CUmI ’y CL A SSICATION 0 r T "IS P*GC/"h4. DA,. I...plotted on a logarithmic scale (Figs. 3c and 3d ). The positions of maxima and minima and the correspond- ing irradiance and encircled-power values are

  13. Optical Faraday Cup for Heavy Ion Beams

    Energy Technology Data Exchange (ETDEWEB)

    Bieniosek, Frank; Bieniosek, F.M.; Eylon, S.; Roy, P.K.; Yu, S.S.

    2007-06-25

    We have been using alumina scintillators for imaging beams in heavy-ion beam fusion experiments in 2 to 4 transverse dimensions [1]. The scintillator has a limited lifetime under bombardment by the heavy ion beams. As a possible replacement for the scintillator, we are studying the technique of imaging the beam on a gas cloud. A gas cloud for imaging the beam may be created on a solid hole plate placed in the path of the beam, or by a localized gas jet. It is possible to image the beam using certain fast-quenching optical lines that closely follow beam current density and are independent of gas density. We describe this technique and show preliminary experimental data. This approach has promise to be a new fast beam current diagnostic on a nanosecond time scale.

  14. Removal of toxicity the pharmaceutical propranolol and your mixture with fluoxetine hydrochloride in aqueous solution using radiation with electron beam; Remocao da toxicidade do farmaco propranolol e de sua mistura com cloridrato de fluoxetina em solucao aquosa empregando irradiacao com feixe de eletrons

    Energy Technology Data Exchange (ETDEWEB)

    Boiani, Nathalia Fonseca

    2016-07-01

    Environmental health has been damage due to incorrect disposal of products and by-products. Among emerging pollutants it is possible to account with several pharmaceuticals, causing those problems when disposed in the environment by effluents. Conventional processing techniques are insufficient in removal of the pharmaceuticals, for having resistant waste and low biodegradability. Thus the advanced oxidation processes have been studied as an alternative for the treatment of different types of effluents. The objective of this study was to apply the process of irradiation with electron beam in order to reduce the toxic effects of propranolol, and the mixture with fluoxetine hydrochloride in aqueous solution. Ecotoxicological tests conducted with propranolol, and the mixture with fluoxetine hydrochloride, for Daphnia similis microcrustacean, and the Vibrio fischeri bacterium. It was observed that D. similis was more sensitive to propranolol drug and to the mixture, when compared to bacterium V.fischeri. After being subjected to the treatment with ionizing radiation, all applied doses to the propranolol and the mixture, showed significant reduction of toxicity, for D. similis. Different were the results for V. fischeri, when only 5.0 kGy reduced toxicity to propranolol. The mixture of pharmaceuticals required 2.5 and 5.0 kGy for reducing toxicity. 5.0 kGy showed the best removal efficiency for toxicity: 79.94 % for D. similis and 15.64 % for V. fischeri, when exposed to propranolol. The mixture reduction efficacy were 81.59% and 26.93 % for D.similis and V.fischeri, respectively. (author)

  15. Active beam spectroscopy for ITER

    Energy Technology Data Exchange (ETDEWEB)

    Hellermann, M.G. von, E-mail: mgvh@jet.u [FOM Institute Rijnhuizen, Euratom Association, 3430BE Nieuwegein (Netherlands); Barnsley, R. [ITER Organization, 13108 St.-Paul-Lez-Durance, Cadarache (France); Biel, W. [Institut fuer Energieforschung, Plasmaphysik, Forschungszentrum Juelich, Euratom Association, 52425 Juelich (Germany); Delabie, E. [FOM Institute Rijnhuizen, Euratom Association, 3430BE Nieuwegein (Netherlands); Hawkes, N. [Culham Centre for Fusion Energy, Euratom Association, Culham OX14 3DB (United Kingdom); Jaspers, R. [FOM Institute Rijnhuizen, Euratom Association, 3430BE Nieuwegein (Netherlands); Johnson, D. [Princeton Plasma Physics Laboratory, Princeton, NJ-08548 (United States); Klinkhamer, F. [TNO Science and Industry, Stieltjesweg 1, 2628CK Delft (Netherlands); Lischtschenko, O. [FOM Institute Rijnhuizen, Euratom Association, 3430BE Nieuwegein (Netherlands); Marchuk, O. [Institut fuer Energieforschung, Plasmaphysik, Forschungszentrum Juelich, Euratom Association, 52425 Juelich (Germany); Schunke, B. [ITER Organization, 13108 St.-Paul-Lez-Durance, Cadarache (France); Singh, M.J. [Institute for Plasma Research, Bhat, Gandhinagar, Gurajat 384828 (India); Snijders, B. [TNO Science and Industry, Stieltjesweg 1, 2628CK Delft (Netherlands); Summers, H.P. [Culham Centre for Fusion Energy, Euratom Association, Culham OX14 3DB (United Kingdom); Thomas, D. [ITER Organization, 13108 St.-Paul-Lez-Durance, Cadarache (France); Tugarinov, S. [TRINITI Troitsk, Moscow Region 142092 (Russian Federation); Vasu, P. [Institute for Plasma Research, Bhat, Gandhinagar, Gurajat 384828 (India)

    2010-11-11

    Since the first feasibility studies of active beam spectroscopy on ITER in 1995 the proposed diagnostic has developed into a well advanced and mature system. Substantial progress has been achieved on the physics side including comprehensive performance studies based on an advanced predictive code, which simulates active and passive features of the expected spectral ranges. The simulation has enabled detailed specifications for an optimized instrumentation and has helped to specify suitable diagnostic neutral beam parameters. Four ITER partners share presently the task of developing a suite of ITER active beam diagnostics, which make use of the two 0.5 MeV/amu 18 MW heating neutral beams and a dedicated 0.1 MeV/amu, 3.6 MW diagnostic neutral beam. The IN ITER team is responsible for the DNB development and also for beam physics related aspects of the diagnostic. The RF will be responsible for edge CXRS system covering the outer region of the plasma (1>r/a>0.4) using an equatorial observation port, and the EU will develop the core CXRS system for the very core (0

  16. Limitations due to strong head-on beam-beam interactions (MD 1434)

    CERN Document Server

    Buffat, Xavier; Iadarola, Giovanni; Papadopoulou, Parthena Stefania; Papaphilippou, Yannis; Pellegrini, Dario; Pojer, Mirko; Crockford, Guy; Salvachua Ferrando, Belen Maria; Trad, Georges; Barranco Garcia, Javier; Pieloni, Tatiana; Tambasco, Claudia; CERN. Geneva. ATS Department

    2017-01-01

    The results of an experiment aiming at probing the limitations due to strong head on beam-beam interactions are reported. It is shown that the loss rates significantly increase when moving the working point up and down the diagonal, possibly due to effects of the 10th and/or 14th order resonances. Those limitations are tighter for bunches with larger beam-beam parameters, a maximum total beam-beam tune shift just below 0.02 could be reached.

  17. Quantized beam shifts in graphene

    Energy Technology Data Exchange (ETDEWEB)

    de Melo Kort-Kamp, Wilton Junior [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Sinitsyn, Nikolai [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dalvit, Diego Alejandro Roberto [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-10-08

    We predict the existence of quantized Imbert-Fedorov, Goos-Hanchen, and photonic spin Hall shifts for light beams impinging on a graphene-on-substrate system in an external magnetic field. In the quantum Hall regime the Imbert-Fedorov and photonic spin Hall shifts are quantized in integer multiples of the fine structure constant α, while the Goos-Hanchen ones in multiples of α2. We investigate the influence on these shifts of magnetic field, temperature, and material dispersion and dissipation. An experimental demonstration of quantized beam shifts could be achieved at terahertz frequencies for moderate values of the magnetic field.

  18. Getting ready for SPS beam

    CERN Multimedia

    1977-01-01

    View from downstream of the WA7 experiment along beam H1B. In the foreground are scintillator hodoscopes and immediately behind them, is a threshold Cerenkov counter, standing on its edge. The WA7 control hut is located on the right, over the concrete shielding blocks. Still more right, the other branch of the H1 beam, E1A/H1A, runs towards the Omega Facility. WA7 by the CERN-Genoa-LAPP, Annecy-Niels Bohr Institute, Copenhagen-Oslo, University College, London Collaboration was meant to study two-body reactions at large transverse momentum.

  19. Low intensity beam target unit

    CERN Multimedia

    1976-01-01

    This is a wheel fitted with many targets around its periphery (each with three longitudinally arranged thin rods) of which one is placed into the beam via a rotation of the wheel. Upstream of each target is placed a luminescent screen, aligbed on each target axis and viewed with a TV camera, to make sure that one is hitting the target. This target unit was probably used to study target's behaviour (like beam heating). Gualtiero Del Torre stands on the left, Pierre Gerdil on the right.

  20. METHOD OF ELECTRON BEAM PROCESSING

    DEFF Research Database (Denmark)

    2003-01-01

    As a rule, electron beam welding takes place in a vacuum. However, this means that the workpieces in question have to be placed in a vacuum chamber and have to be removed therefrom after welding. This is time−consuming and a serious limitation of a process the greatest advantage of which...... is the option of welding workpieces of large thicknesses. Therefore the idea is to guide the electron beam (2) to the workpiece via a hollow wire, said wire thereby acting as a prolongation of the vacuum chamber (4) down to workpiece. Thus, a workpiece need not be placed inside the vacuum chamber, thereby...