WorldWideScience

Sample records for beam quality monitor

  1. Summary Of Session 4: How Do We Monitor Beam Quality?

    International Nuclear Information System (INIS)

    Up to the end of the 80's beam quality was mainly believed to be connected only to the intensity i.e. beam quantity. However, with the new colliders already functioning or programmed, new and more (also in safety) demanding production machines (e.g. isotope) and the many new 3rd generation synchrotron radiation sources that accommodate many experimental lines, the beam quality (BQ) issue has to be re-examined, re-evaluated and re-defined. (author)

  2. LHCB: A LHCb-VELO module as beam quality monitor for proton therapy beam at the Clatterbridge Centre for Oncology

    CERN Multimedia

    Casse, G; Patel, G D; Smith, N A; Kacperek, A; Marsland, B

    2010-01-01

    The progress in detector technology, driven by the needs of particle tracking and vertexing in the present LHC and its upgrade (sLHC), has led to the design of silicon sensors with low mass, high granularity, high speed and unprecedented radiation hardness. The sensors designed for such a harsh environment can be profitably used for instrumenting the control systems of therapeutic hadron beams. The high granularity and readout clock speed are well suited for monitoring continuous beam currents. The low mass allows reduced interference with the beam whilst monitoring its profile with high precision. The high resolution and sensitivity to minimum ionising particles allows monitoring of the beam spot position by measurement of the halo in real time, without any interference with the beam spot used in therapy.

  3. Short bunched beam monitor

    International Nuclear Information System (INIS)

    In order to monitor the short bunched beam, two types of monitors were developed and tested. A core monitor using a Co-based amorphous core which has high μ characteristics and high frequency response can be used as a non-destructive current monitor for the beam in the range of 1ns to several μs pulse width. A wall current monitor designed carefully has been also tested. The wall current monitor has measured the beam shape with the pulse width of 200ps or less. In this paper the characteristics and overall performance of these monitors are described. (author)

  4. Cavity beam position monitors

    International Nuclear Information System (INIS)

    Beam-based alignment and feedback systems are essential for the operation of future linear colliders and free electron lasers. A certain number of beam position monitors with a resolution in the submicron range are needed at selected locations. Most beam position monitors detect the electric or the magnetic field excited by a beam of charged particles at different locations around the beam pipe. In resonant monitors, however, the excitation of special field configurations by an off-center beam is detected. These structures offer a large signal per micron displacement. This paper is an attempt to summarize the fundamental characteristics of resonant monitors, their advantages and shortcomings. Emphasis will be on the design of cylindrical cavities, in particular on the estimation of expected signals, of resolution limits and the resulting beam distortion. This includes also a short introduction into numerical methods. Fabrication, tuning, and other practical problems will be reviewed briefly. Finally, some resonant devices used for beam position diagnostics will be discussed and listed

  5. Data Quality Monitoring Framework for ATLAS Experiment: Performance Achieved with Colliding Beams at LHC

    CERN Document Server

    Corso-Radu, A; The ATLAS collaboration; Ilchenko, Y; Kolos, S; Okawa, H; Slagle, K; Taffard, A

    2010-01-01

    With the delivery of the first proton-proton collisions by the LHC, the ATLAS collaboration had the opportunity to operate the detector under the environment it was designed for. These first runs have been of great interest not only for the high energy physics outcome, but also were used to perform a general commissioning of the system. The online data quality monitoring framework (DQMF) is a highly scalable distributed framework that is used to assess the quality of the data and the operational conditions of the detector, trigger and data acquisition system. DQMF provides quick feedback to the user about the correct functioning and performance of different parts of the detector, it quickly spots problems related with data quality and allows one to determine the origin of these problems. DQMF performs over forty thousand advanced data quality checks at a rate that depends on the histogram update frequency and it displays histograms and results of these checks on several dozens of monitors installed in the mai...

  6. Data Quality Monitoring Framework for ATLAS Experiment: Performance Achieved with Colliding Beams at LHC

    CERN Document Server

    Corso-Radu, A; The ATLAS collaboration; Ilchenko, Y; Kolos, S; Okawa, H; Slagle, K; Taffard, A

    2011-01-01

    This first year of data taking has been of great interest, not only for the physics outcome, but also for operating the system under the environment it was designed for. The online data quality monitoring framework (DQMF) is a highly scalable distributed framework which is used to assess the operational conditions of the detector and the quality of the data. DQMF provides quick feedback to the user about the functioning and performance of the sub-detectors by performing over 75,000 advanced data quality checks, with rates varying depending on histogram update frequency. The DQM display (DQMD) is the visualisation tool with which histograms and their data quality assessments can be accessed. It allows for great flexibility for displaying histograms, their reference when applicable, configurations used for the automatics checks, data quality flags and much more. The DQM configuration is stored in a database that can be easily created and edited with the DQM Configurator tool (DQMC). This paper is describing the...

  7. The ATLAS Diamond Beam Monitor

    CERN Document Server

    Schaefer, Douglas; The ATLAS collaboration

    2015-01-01

    After the first three years of the LHC running the ATLAS experiment extracted it's pixel detector system to refurbish and re-position the optical readout drivers and install a new barrel layer of pixels. The experiment has also taken advantage of this access to also install a set of beam monitoring telescopes with pixel sensors, four each in the forward and backward regions. These telescopes were assembled based on chemical vapour deposited (CVD) diamond sensors to survive in this high radiation environment without needing extensive cooling. This talk will describe the lessons learned in construction and commissioning of the ATLAS x Diamond Beam Monitor (DBM). We will show results from the construction quality assurance tests, commissioning performance, including results from cosmic ray running in early 2015 and also expected first results from LHC run 2 collisions.

  8. Beam Position Monitor Engineering

    International Nuclear Information System (INIS)

    The design of beam position monitors often involves challenging system design choices. Position transducers must be robust, accurate, and generate adequate position signal without unduly disturbing the beam. Electronics must be reliable and affordable, usually while meeting tough requirements on precision. accuracy, and dynamic range. These requirements may be difficult to achieve simultaneously, leading the designer into interesting opportunities for optimization or compromise. Some useful techniques and tools are shown. Both finite element analysis and analytic techniques will be used to investigate quasi-static aspects of electromagnetic fields such as the impedance of and the coupling of beam to striplines or buttons. Finite-element tools will be used to understand dynamic aspects of the electromagnetic fields of beams, such as wake-fields and transmission-line and cavity effects in vacuum-to-air feed through. Mathematical modeling of electrical signals through a processing chain will be demonstrated, in particular to illuminate areas where neither a pure time-domain nor a pure frequency-domain analysis is obviously advantageous. Emphasis will be on calculational techniques, in particular on using both time-domain and frequency domain approaches to the applicable parts of interesting problems

  9. In Process Beam Monitoring

    Science.gov (United States)

    Steen, W. M.; Weerasinghe, V. M.

    1986-11-01

    The industrial future of lasers in material processing lies in the combination of the laser with automatic machinery. One possible form of such a combination is an intelligent workstation which monitors the process as it occurs and adjusts itself accordingly, either by self teaching or by comparison to a process data bank or algorithm. In order to achieve this attractive goal in-process signals are required. Two devices are described in this paper. One is the Laser Beam Analyser which is now maturing into a second generation with computerised output. The other is the Acoustic Mirror, a totally novel analytic technique, not yet fully understood, but which nevertheless can act as a very effective process monitor.

  10. Beam quality measure for vector beams.

    Science.gov (United States)

    Ndagano, Bienvenu; Sroor, Hend; McLaren, Melanie; Rosales-Guzmán, Carmelo; Forbes, Andrew

    2016-08-01

    Vector beams have found a myriad of applications, from laser materials processing to microscopy, and are now easily produced in the laboratory. They are usually differentiated from scalar beams by qualitative measures, for example, visual inspection of beam profiles after a rotating polarizer. Here we introduce a quantitative beam quality measure for vector beams and demonstrate it on cylindrical vector vortex beams. We show how a single measure can be defined for the vector quality, from 0 (purely scalar) to 1 (purely vector). Our measure is derived from a quantum toolkit, which we show applies to classical vector beams. PMID:27472580

  11. Electrostatic beam-position monitor

    CERN Multimedia

    CERN PhotoLab

    1969-01-01

    Electrostatic beam-position monitor installed in its final location (bake-out cover removed). The ISR will contain about 110 of these monitors. Their accuracy is better than 1 mm, their band width about 1 MHz.

  12. LEDA BEAM DIAGNOSTICS INSTRUMENTATION: BEAM POSITION MONITORS

    International Nuclear Information System (INIS)

    The Low Energy Demonstration Accelerator (LEDA) facility located at Los Alamos National Laboratory (LANL) accelerates protons to an energy of 6.7-MeV and current of 100-mA operating in either a pulsed or cw mode. Of key importance to the commissioning and operations effort is the Beam Position Monitor system (BPM). The LEDA BPM system uses five micro-stripline beam position monitors processed by log ratio processing electronics with data acquisition via a series of custom TMS32OC40 Digital Signal Processing (DSP) boards. Of special interest to this paper is the operation of the system, the log ratio processing, and the system calibration technique. This paper will also cover the DSP system operations and their interaction with the main accelerator control system

  13. Beam Position Monitoring at CLIC

    CERN Document Server

    Prochnow, J

    2003-01-01

    At the European Organisation for Nuclear Research CERN in Geneva, Switzerland the design of the Compact LInear Collider (CLIC) for high energy physics is studied. To achieve the envisaged high luminosity the quadrupole magnets and radio-frequency accelerating structures have to be actively aligned with micron precision and submicron resolution. This will be done using beam-based algorithms which rely on beam position information inside of quadrupoles and accelerating structures. After a general introduction to the CLIC study and the alignment algorithms, the concept of the interaction between beams and radio-frequency structures is given. In the next chapter beam measurements and simulations are described which were done to study the performance of cavity beam position monitors (BPM). A BPM design is presented which is compatible with the multi-bunch operation at CLIC and could be used to align the quadrupoles. The beam position inside the accelerating structures will be measured by using the structures thems...

  14. Micromegas neutron beam monitor neutronics.

    Science.gov (United States)

    Stephan, Andrew C; Miller, Laurence F

    2005-01-01

    The Micromegas is a type of ionising radiation detector that consists of a gas chamber sandwiched between two parallel plate electrodes, with the gas chamber divided by a Frisch grid into drift and amplification gaps. Investigators have applied it to a number of different applications, such as charged particle, X-ray and neutron detection. A Micromegas device has been tested as a neutron beam monitor at CERN and is expected to be used for that purpose at the Spallation Neutron Source (SNS) under construction in Oak Ridge, TN. For the Micromegas to function effectively as neutron beam monitor, it should cause minimal disruption to the neutron beam in question. Specifically, it should scatter as few neutrons as possible and avoid neutron absorption when it does not contribute to generating useful information concerning the neutron beam. Here, we present the results of Monte Carlo calculations of the effect of different types of wall materials and detector gases on neutron beams and suggest methods for minimising disruption to the beam. PMID:16381746

  15. Air Quality Monitoring Programme

    DEFF Research Database (Denmark)

    Kemp, K.; Palmgren, F.

    The air quality in Danish cities has been monitored continuously since 1982 within the Danish Air Quality (LMP) network. The aim has been to follow the concentration levels of toxic pollutants in the urban atmosphere and to provide the necessary knowledge to assess the trends, to perform source...... apportionment, and to evaluate the chemical reactions and the dispersion of the pollutants in the atmosphere. In 2002 the air quality was measured in four Danish cities and at two background sites. NO2 and PM10 were at several stations found in concentrations above the new EU limit values, which the Member...

  16. Laser beam welding quality monitoring system based in high-speed (10 kHz) uncooled MWIR imaging sensors

    Science.gov (United States)

    Linares, Rodrigo; Vergara, German; Gutiérrez, Raúl; Fernández, Carlos; Villamayor, Víctor; Gómez, Luis; González-Camino, Maria; Baldasano, Arturo; Castro, G.; Arias, R.; Lapido, Y.; Rodríguez, J.; Romero, Pablo

    2015-05-01

    The combination of flexibility, productivity, precision and zero-defect manufacturing in future laser-based equipment are a major challenge that faces this enabling technology. New sensors for online monitoring and real-time control of laserbased processes are necessary for improving products quality and increasing manufacture yields. New approaches to fully automate processes towards zero-defect manufacturing demand smarter heads where lasers, optics, actuators, sensors and electronics will be integrated in a unique compact and affordable device. Many defects arising in laser-based manufacturing processes come from instabilities in the dynamics of the laser process. Temperature and heat dynamics are key parameters to be monitored. Low cost infrared imagers with high-speed of response will constitute the next generation of sensors to be implemented in future monitoring and control systems for laser-based processes, capable to provide simultaneous information about heat dynamics and spatial distribution. This work describes the result of using an innovative low-cost high-speed infrared imager based on the first quantum infrared imager monolithically integrated with Si-CMOS ROIC of the market. The sensor is able to provide low resolution images at frame rates up to 10 KHz in uncooled operation at the same cost as traditional infrared spot detectors. In order to demonstrate the capabilities of the new sensor technology, a low-cost camera was assembled on a standard production laser welding head, allowing to register melting pool images at frame rates of 10 kHz. In addition, a specific software was developed for defect detection and classification. Multiple laser welding processes were recorded with the aim to study the performance of the system and its application to the real-time monitoring of laser welding processes. During the experiments, different types of defects were produced and monitored. The classifier was fed with the experimental images obtained. Self

  17. Air Quality Monitoring Programme

    DEFF Research Database (Denmark)

    Kemp, K.; Palmgren, F.

    The Danish Air Quality Monitoring Programme (LMP IV) has been revised in accordance with the Framework Directive and the first three daughter directives of SO2, NOx/NO2, PM10, lead, benzene, CO and ozone. PM10 samplers are under installation and the installation will be completed during 2002...

  18. The CMS Beam Halo Monitor electronics

    Science.gov (United States)

    Tosi, N.; Dabrowski, A. E.; Fabbri, F.; Grassi, T.; Hughes, E.; Mans, J.; Montanari, A.; Orfanelli, S.; Rusack, R.; Torromeo, G.; Stickland, D. P.; Stifter, K.

    2016-02-01

    The CMS Beam Halo Monitor has been successfully installed in the CMS cavern in LHC Long Shutdown 1 for measuring the machine induced background for LHC Run II. The system is based on 40 detector units composed of synthetic quartz Cherenkov radiators coupled to fast photomultiplier tubes (PMTs). The readout electronics chain uses many components developed for the Phase 1 upgrade to the CMS Hadronic Calorimeter electronics, with dedicated firmware and readout adapted to the beam monitoring requirements. The PMT signal is digitized by a charge integrating ASIC (QIE10), providing both the signal rise time, with few nanosecond resolution, and the charge integrated over one bunch crossing. The backend electronics uses microTCA technology and receives data via a high-speed 5 Gbps asynchronous link. It records histograms with sub-bunch crossing timing resolution and is read out via IPbus using the newly designed CMS data acquisition for non-event based data. The data is processed in real time and published to CMS and the LHC, providing online feedback on the beam quality. A dedicated calibration monitoring system has been designed to generate short triggered pulses of light to monitor the efficiency of the system. The electronics has been in operation since the first LHC beams of Run II and has served as the first demonstration of the new QIE10, Microsemi Igloo2 FPGA and high-speed 5 Gbps link with LHC data.

  19. A better beam quality

    CERN Multimedia

    CERN Bulletin

    2010-01-01

    Progress has been made on two fronts, providing physics data and preparing for higher intensities. Over the Whitsun weekend of May 22 to 24, 5 fills for physics provided almost 30 hours of stable colliding beams, all with bunch intensities around 2x1010 protons and at a β* of 2m. The first three of these fills were with 6 bunches per beam, giving 3 pairs of collisions in all experiments. For the other two fills, the number of bunches per beam was increased to 13, giving 8 pairs of colliding bunches, and for the first time luminosities were pushed above 1029 cm-2s-1, 2 orders of magnitude higher than first collisions in March. In between and after these physics fills, nominal bunches of 1011 protons were successfully ramped and brought into collision in ATLAS and CMS for the first time (not in stable beam conditions and without squeeze). Event rates seen by the experiments were in the expected range for these conditions. In the middle of this work, a short fill with beams of 7 nominal bunches was ...

  20. The ATLAS beam conditions monitor

    CERN Document Server

    Mikuz, M; Dolenc, I; Kagan, H; Kramberger, G; Frais-Kölbl, H; Gorisek, A; Griesmayer, E; Mandic, I; Pernegger, H; Trischuk, W; Weilhammer, P; Zavrtanik, M

    2006-01-01

    The ATLAS beam conditions monitor is being developed as a stand-alone device allowing to separate LHC collisions from background events induced either on beam gas or by beam accidents, for example scraping at the collimators upstream the spectrometer. This separation can be achieved by timing coincidences between two stations placed symmetric around the interaction point. The 25 ns repetition of collisions poses very stringent requirements on the timing resolution. The optimum separation between collision and background events is just 12.5 ns implying a distance of 3.8 m between the two stations. 3 ns wide pulses are required with 1 ns rise time and baseline restoration in 10 ns. Combined with the radiation field of 10/sup 15/ cm/sup -2/ in 10 years of LHC operation only diamond detectors are considered suitable for this task. pCVD diamond pad detectors of 1 cm/sup 2/ and around 500 mum thickness were assembled with a two-stage RF current amplifier and tested in proton beam at MGH, Boston and SPS pion beam at...

  1. Application of Diamond Based Beam Loss Monitors

    OpenAIRE

    Hempel, Maria

    2013-01-01

    The LHC has an operational stored energy of 130MJ per beam. Only a small percentage of beam losses in the LHC equipment can damage material or lead to magnet quenches. Therefore, it is important to monitor different types of beam losses, e.g. scattering on residual gas particles, UFOs, collisions and injection losses. A detailed understanding of beam loss mechanisms is necessary to reduce them and ensure save operation. Two different beam loss monitors are installed in the LHC tunnel: ionizat...

  2. Calibration of waveguide beam position monitors

    CERN Document Server

    Kamps, T

    2000-01-01

    To ensure overlap between the photon beam and electron beam at the SASE-FEL at the TESLA Test Facility, several position-sensitive diagnostics components are installed along the beamline of the FEL. For the undulator part, a new type of waveguide beam position monitors (BPMs) is designed, tested, and installed inside the beam pipe of one undulator module. This paper proposes a method to calibrate these monitors with beam-based measurements

  3. Beam intensity monitoring for the external proton beam at LAMPF

    International Nuclear Information System (INIS)

    Three different intensity monitors were tested in the external proton beam at LAMPF, and together cover the entire range of beam currents available. A 800 kg Faraday cup was installed and used to measure the absolute intensity to better than 1 percent for beam currents up to several nanoamperes. A high gain ion chamber was used as part of the calibration procedure for the Faraday cup, and was found to be useful when monitoring very small beam intensities, being reliable down to the few picoampere level. A secondary emission monitor was also tested, calibrated, and found to be trustworthy only for beams of greater than 50 pA intensity. (auth)

  4. The CMS Beam Halo Monitor Detector System

    CERN Document Server

    CMS Collaboration

    2015-01-01

    A new Beam Halo Monitor (BHM) detector system has been installed in the CMS cavern to measure the machine-induced background (MIB) from the LHC. This background originates from interactions of the LHC beam halo with the final set of collimators before the CMS experiment and from beam gas interactions. The BHM detector uses the directional nature of Cherenkov radiation and event timing to select particles coming from the direction of the beam and to suppress those originating from the interaction point. It consists of 40 quartz rods, placed on each side of the CMS detector, coupled to UV sensitive PMTs. For each bunch crossing the PMT signal is digitized by a charge integrating ASIC and the arrival time of the signal is recorded. The data are processed in real time to yield a precise measurement of per-bunch-crossing background rate. This measurement is made available to CMS and the LHC, to provide real-time feedback on the beam quality and to improve the efficiency of data taking. In this talk we will describ...

  5. The CMS Beam Halo Monitor Detector System

    CERN Document Server

    Stifter, Kelly Marie

    2015-01-01

    A new Beam Halo Monitor (BHM) detector system has been installed in the CMS cavern to measure the machine-induced background (MIB) from the LHC. This background originates from interactions of the LHC beam halo with the final set of collimators before the CMS experiment and from beam gas interactions. The BHM detector uses the directional nature of Cherenkov radiation and event timing to select particles coming from the direction of the beam and to supress those originating from the interaction point. It consists of 40 quartz rods, placed on each side of the CMS detector, coupled to UV sensitive PMTs. For each bunch crossing the PMT signal is digitized by a charge integrating ASIC and the arrival time of the signal is recorded. The data are processed in real time to yield a precise measurement of per-bunch-crossing background rate. This measurement is made available to CMS and the LHC, to provide real-time feedback on the beam quality and to improve the efficiency of data taking. In this talk we will descri...

  6. The CMS Beam Halo Monitor Detector System

    CERN Document Server

    Stifter, Kelly

    2015-01-01

    A new Beam Halo Monitor (BHM) detector system has been installed in the CMS cavern to measure the machine-induced background (MIB) from the LHC. This background originates from interactions of the LHC beam halo with the final set of collimators before the CMS experiment and from beam gas interactions. The BHM detector uses the directional nature of Cherenkov radiation and event timing to select particles coming from the direction of the beam and to suppress those originating from the interaction point. It consists of 40 quartz rods, placed on each side of the CMS detector, coupled to UV sensitive PMTs. For each bunch crossing the PMT signal is digitized by a charge integrating ASIC and the arrival time of the signal is recorded. The data are processed in real time to yield a precise measurement of per-bunch-crossing background rate. This measurement is made available to CMS and the LHC, to provide real-time feedback on the beam quality and to improve the efficiency of data taking. Here, I present the detector...

  7. Development of proton beam monitoring devices

    International Nuclear Information System (INIS)

    We develop an 1 channel ionization chamber for beam monitoring system of KOMAC 20/100 MeV proton accelerator with a crystal scintillator, and try to make Multi Functional detectors, which can cover wide range of proton current. After the development, it is possible to provide the beam information to KOMAC beam users. We also develop a fast neutron detector system to detect the proton recoil by the neutron in the beam line. This system can provide the neutron dose information to beam user for safety. The followings are our major study 1) Beam profile and energy monitoring by using scintillators 2) Development of 32 channel Charge integration Embedded DAQ board 3) 1 channel gas scintillation detector for pulse beam monitoring 4) Development of fast neutron detector. Results Our major achievements are as follows ; 1) XY distribution scanning of proton beam by using LYSO crystal scintillator, 2) Development of a 32 channel Charge integration Embedded DAQ board and test it on beam line, 3) Development of 1 channel gas scintillation detector for pulse beam monitoring and test at KOMAC beam line. 4) Development of fast neutron detectors such as liquid scintillator and stilbene and measured neutron at beam line. The most important achievements of this research are ; 1) We measured the timing structure of proton beam by using 1 ch gas scintillation detector, and 2) it was possible to scanning the XY distribution of proton beam at real time

  8. Tevatron Beam Position Monitor Upgrade

    CERN Document Server

    Wolbers, Stephen; Barker, B; Bledsoe, S; Boes, T; Bowden, Mark; Cancelo, Gugstavo I; Dürling, G; Forster, B; Haynes, B; Hendricks, B; Kasza, T; Kutschke, Robert K; Mahlum, R; Martens, Michael A; Mengel, M; Olsen, M; Pavlicek, V; Pham, T; Piccoli, Luciano; Steimel, Jim; Treptow, K; Votava, Margaret; Webber, Robert C; West, B; Zhang, D

    2005-01-01

    The Tevatron Beam Position Monitor (BPM) readout electronics and software have been upgraded to improve measurement precision, functionality and reliability. The original system, designed and built in the early 1980s, became inadequate for current and future operations of the Tevatron. The upgraded system consists of 960 channels of new electronics to process analog signals from 240 BPMs, new front-end software, new online and controls software, and modified applications to take advantage of the improved measurements and support the new functionality. The new system reads signals from both ends of the existing directional stripline pickups to provide simultaneous proton and antiproton position measurements. Measurements using the new system are presented that demonstrate its improved resolution and overall performance.

  9. The beam quality parameter of spirally polarized beams

    Science.gov (United States)

    Ramírez-Sánchez, V.; Piquero, G.

    2008-12-01

    Starting from the expression for the quality parameter of a superposition of two general fields, the case of beams that can be written in terms of the polarization basis introduced by Gori is investigated. Different types of this class of beam are studied and compared. In particular, spirally polarized beams are considered. As an example, polarized Bessel-Gauss beams are analyzed in detail.

  10. The Electro-Optic Beam Position Monitor

    CERN Document Server

    Doherty, James

    2013-01-01

    This reports outlines the development of a new ultra-wideband electro-optic beam position monitor (EO-BPM) for use in the Large Hadron Collider (LHC) which utilises birefringent crystals and the Pockels effect to monitor beam position. The physical principles behind the operation of the device and tested topology, which incorporates two Lithium Tantalate crystals, is discussed.

  11. ATLAS online data quality monitoring

    CERN Document Server

    Cuenca Almenar, C; The ATLAS collaboration; Hadavand, H; Ilchenko, Y; Kolos, S; Slagle, K; Taffard, A

    2010-01-01

    Every minute the ATLAS detector is taking data, the monitoring framework serves several thousands physics events to monitoring data analysis applications, handles millions of histogram updates coming from thousands applications, executes over forty thousand advanced data quality checks for a subset of those histograms, displays histograms and results of these checks on several dozens of monitors installed in main and satellite ATLAS control rooms. The online data quality monitoring system has been of great help in providing quick feedback to the subsystems about the functioning and performance of the different parts of ATLAS by providing a configurable easy and fast visualization of all this information. The Data Quality Monitoring Display (DQMD) is a visualization tool for the automatic data quality assessment of the ATLAS experiment. It is the interface through which the shift crew and experts can validate the quality of the data being recorded or processed, be warned of problems related to data quality, an...

  12. Gas Filled RF Resonator Hadron Beam Monitor for Intense Neutrino Beam Experiments

    Energy Technology Data Exchange (ETDEWEB)

    Yonehara, Katsuya [Fermilab; Abrams, Robert [MUONS Inc., Batavia; Dinkel, Holly [U. Missouri, Columbia; Freemire, Ben [IIT, Chicago; Johnson, Rolland [MUONS Inc., Batavia; Kazakevich, Grigory [MUONS Inc., Batavia; Tollestrup, Alvin [Fermilab; Zwaska, Robert [Fermilab

    2016-06-01

    MW-class beam facilities are being considered all over the world to produce an intense neutrino beam for fundamental particle physics experiments. A radiation-robust beam monitor system is required to diagnose the primary and secondary beam qualities in high-radiation environments. We have proposed a novel gas-filled RF-resonator hadron beam monitor in which charged particles passing through the resonator produce ionized plasma that changes the permittivity of the gas. The sensitivity of the monitor has been evaluated in numerical simulation. A signal manipulation algorithm has been designed. A prototype system will be constructed and tested by using a proton beam at the MuCool Test Area at Fermilab.

  13. Requirements of CLIC Beam Loss Monitoring System

    CERN Document Server

    Sapinski, M; Holzer, EB; Jonker, M; Mallows, S; Otto, T; Welsch, C

    2010-01-01

    The Compact Linear Collider (CLIC) [1] is a proposed multi-TeV linear electron-positron collider being designed by a world-wide collaboration. It is based on a novel twobeam acceleration scheme in which two beams (drive and main beam) are placed in parallel to each other and energy is transferred from the drive beam to the main one. Beam losses on either of them can have catastrophic consequences for the machine, because of high intensity (drive beam) or high energy and small emittance (main beam). In the framework of machine protection, a Beam Loss Monitoring (BLM) system has to be put in place. This paper discusses the requirements for the beam loss system in terms of detector sensitivity, resolution, dynamic range and ability to distinguish losses originating from various sources. The two-beam module where the protection from beam losses is particularly challenging and important, is studied.

  14. Water Quality Monitoring

    Data.gov (United States)

    US Fish and Wildlife Service, Department of the Interior — Our water quality sampling program is to determine the quality of Moosehorn's lakes and a limited number of streams. Water quality is a measure of the body of...

  15. Beam Profile Monitors in the Nlcta

    OpenAIRE

    Nantista, C.; Adolphsen, C.; Brown, R L; Fuller, R.; Rifkin, J.

    2000-01-01

    The transverse current profile in the Next Linear Collider Test Accelerator (NLCTA) electron beam can be monitored at several locations along the beam line by means of profile monitors. These consist of insertable phosphor screens, light collection and transport systems, CID cameras, a frame-grabber, and PC and VAX based image analysis software. In addition to their usefulness in tuning and steering the accelerator, the profile monitors are utilized for emittance measurement. A description of...

  16. Beam test of wire scanner beam size monitor

    International Nuclear Information System (INIS)

    A beam size monitor for emittance measurement is required to have around 10μm resolution for injector linac, and to have a few tenth μm resolution for an extracted beam from a damping ring in Accelerator Test Facility (ATF). A wire scanner is a one of the candidate of a beam size monitor with a high resolution. The design and development study of the wire scanning stage has been done. The beam test using Tohoku 300MeV Linac was done and the emittance was measured by this wire scanner. A detection of beam size signal was done by a scintillator gamma detector placed at downstream of the wire stage. All of the measurements are taken by the computer. The beam test results are described. (author)

  17. Beam steering using quadrupoles as position monitors

    International Nuclear Information System (INIS)

    An algorithm is proposed to center the beam in the quadrupoles of a transfer line, by changing the focusing strength of a quadrupole and observing the resulting position shift on a monitor downstream. The observed position shift depends linearly on the beam position offset in the quadrupole, provided the phase advance between the quadrupole and the monitor is not a multiple of π. The same monitor may thus be used to center the beam in several places of the beam line. The centering accuracy depends on the resolution of the monitor and on the quadrupole current increment which can be set in such a way that the beam profile remains sufficiently peaked to determine its mean position

  18. Beam Loss Monitors at the ESRF

    CERN Document Server

    Joly, B; Naylor, G A

    2000-01-01

    The European Synchrotron radiation facility is a third generation x-ray source providing x-rays on a continuous basis. As a facility available to external users, the monitoring of radiation caused by the loss of high-energy stored beam is of great concern. A network of beam loss monitors has been installed inside the storage ring tunnel so as to detect and localize the slow loss of electrons during a beam decay. This diagnostic tool allows optimization of beam parameters and physical aperture limits as well as giving useful information on the machine to allow the lifetime to be optimized and defects localized.

  19. Beam monitor system for high-energy beam transportation at HIMAC

    International Nuclear Information System (INIS)

    Heavy-Ion Medical Accelerator in Chiba (HIMAC) provides ion beams for radiotherapy of cancers and for other basic researches. High-energy beam transport lines deliver the beams to three treatment rooms and two experiment rooms with the aid of 41 beam monitor units. Each monitor unit consists of a wire grid as a profile monitor, or a combined unit in which the wire grid and a parallel plate ionization chamber are united for an additional measurement of a beam intensity. They are operated in a mixed gas of 80% Ar and 20% CO2. The gas gain of the wire grid achieves about 8000 at an applied voltage of -2700 V. Dynamic ranges of the wire gird and the parallel plate ionization chamber were measured to be 8x105 and 1x106 in test using ion beams, respectively. A control system of these monitor units offers easy operation, so that operators are almost free from miss-operations. The monitor units are interlocked with a system which protects patients from the undesired irradiation. Five wire grids are used for continuously monitoring the beam during treatments, which play a role in keeping qualities of the treatments. The monitor system has been designed to meet requirements for medical uses, and works in a stable and reliable manner and satisfies the requirements. (author)

  20. Monitor tables for electron beams in radiotherapy

    International Nuclear Information System (INIS)

    The application of electron beams in radiotherapy is still based on tables of monitor units, although 3-D treatment planning systems for electron beams are available. This have several reasons: The need for 3-D treatment planning is not recognized; there is no confidence in the calculation algorithm; Monte-Carlo algorithms are too time-consuming; and the effort necessary to measure basic beam data for 3-D planning is considered disproportionate. However, the increasing clinical need for higher dosimetric precision and for more conformal electron beams leads to the requirement for more sophisticated tables of monitor units. The present paper summarizes and discusses the main aspects concerning the preparation of tables of monitor units for electron beams. The measurement equipment and procedures for measuring basic beam data needed for tables of monitor units for electron beams are described for a standard radiation therapy linac. The design of tables of monitor units for standard electron applicators is presented; this design can be extended for individual electron inserts, to variable applicator surface distances, to oblique beam incidence, and the use of bolus material. Typical data of an Elekta linac are presented in various tables. (orig.)

  1. Application of diamond based beam loss monitors

    International Nuclear Information System (INIS)

    The LHC has an operational stored energy of 130MJ per beam. Only a small percentage of beam losses in the LHC equipment can damage material or lead to magnet quenches. Therefore, it is important to monitor different types of beam losses, e.g. scattering on residual gas particles, UFOs, collisions and injection losses. A detailed understanding of beam loss mechanisms is necessary to reduce them and ensure save operation. Two different beam loss monitors are installed in the LHC tunnel: ionization chambers and diamond sensors. Ionization chambers trigger a beam dump if beam losses exceed a certain threshold. They have a time resolution of 40um (half LHC turn) which is not sufficient to resolve bunch-by-bunch beam losses. Diamond sensors have a nanosecond time resolution and can therefore detect bunch-by-bunch beam losses. This time resolution allows an analysis of various types of beam losses and an understanding of the mechanisms. For the first time beam loss intensities were measured bunch-by-bunch caused by different origins of losses. Beam loss measurements using diamond sensors will be presented. The results are compared to simulations and good qualitative agreement was found. The potential of diamond sensors for LHC and experiment applications are discussed.

  2. Application of diamond based beam loss monitors

    Energy Technology Data Exchange (ETDEWEB)

    Hempel, Maria [Brandenburgische Technische Univ. Cottbus (Germany); DESY, Zeuthen (Germany); CERN, Geneva (Switzerland); Baer, Tobias [CERN, Geneva (Switzerland); Hamburg Univ. (Germany); Castro Carballo, Elena Maria [DESY, Zeuthen (Germany); Lohmann, Wolfgang [Brandenburgische Technische Univ. Cottbus (Germany); DESY, Zeuthen (Germany); Schmidt, Ruediger [CERN, Geneva (Switzerland)

    2013-07-01

    The LHC has an operational stored energy of 130MJ per beam. Only a small percentage of beam losses in the LHC equipment can damage material or lead to magnet quenches. Therefore, it is important to monitor different types of beam losses, e.g. scattering on residual gas particles, UFOs, collisions and injection losses. A detailed understanding of beam loss mechanisms is necessary to reduce them and ensure save operation. Two different beam loss monitors are installed in the LHC tunnel: ionization chambers and diamond sensors. Ionization chambers trigger a beam dump if beam losses exceed a certain threshold. They have a time resolution of 40um (half LHC turn) which is not sufficient to resolve bunch-by-bunch beam losses. Diamond sensors have a nanosecond time resolution and can therefore detect bunch-by-bunch beam losses. This time resolution allows an analysis of various types of beam losses and an understanding of the mechanisms. For the first time beam loss intensities were measured bunch-by-bunch caused by different origins of losses. Beam loss measurements using diamond sensors will be presented. The results are compared to simulations and good qualitative agreement was found. The potential of diamond sensors for LHC and experiment applications are discussed.

  3. ATLAS Online Data Quality Monitoring

    CERN Document Server

    Cuenca Almenar, C; The ATLAS collaboration

    2010-01-01

    With the delivery of the first proton-proton collisions by the LHC, the ATLAS collaboration had the opportunity to operate the detector under the environment it was designed for. These first events have been of great interest not only for the high energy physics outcome, but also as a means to perform a general commissioning of system. A highly scalable distributed monitoring framework assesses the quality of the data and the operational conditions of the detector, trigger and data acquisition system. Every minute of an ATLAS data taking session the monitoring framework serves several thousands physics events to monitoring data analysis applications, handles millions of histogram updates coming from thousands applications, executes over forty thousand advanced data quality checks for a subset of those histograms, displays histograms and results of these checks on several dozens of monitors installed in main and satellite ATLAS control rooms. The online data quality monitoring system has been of great help in ...

  4. ATLAS online data quality monitoring

    CERN Document Server

    Cuenca Almenar, C; The ATLAS collaboration

    2010-01-01

    With the delivery of the first proton-proton collisions by the LHC, the ATLAS collaboration had the opportunity to operate the detector under the environment it was designed for. These first events have been of great interest not only for the high energy physics outcome, but also as a means to perform a general commissioning of system. A highly scalable distributed monitoring framework assesses the quality of the data and the operational conditions of the detector, trigger and data acquisition system. Every minute of an ATLAS data taking session the monitoring framework serves several thousands physics events to monitoring data analysis applications, handles millions of histogram updates coming from thousands applications, executes over forty thousand advanced data quality checks for a subset of those histograms, displays histograms and results of these checks on several dozens of monitors installed in main and satellite ATLAS control rooms. The online data quality monitoring system has been of great help in ...

  5. Monitor of SC beam profiles

    CERN Multimedia

    1977-01-01

    A high-resolution secondary emission grid for the measurement of SC beam profiles. Modern techniques of metal-ceramic bonding, developed for micro-electronics, have been used in its construction. (See Annual Report 1977 p. 105 Fig. 12.)

  6. ATF beam image monitor software

    International Nuclear Information System (INIS)

    We report about software for the beam image analysis at ATF. We developed image analysis software with a Linux computer. It acquire image data from a video and an IEEE1394 digital camera of the analog. (author)

  7. Beam position monitoring at CLIC

    OpenAIRE

    Prochnow, Jan Erik

    2003-01-01

    At the European Organisation for Nuclear Research CERN in Geneva, Switzerland the design of the Compact LInear Collider (CLIC) for high energy physics is studied. To achieve the envisaged high luminosity the quadrupole magnets and radio-frequency accelerating structures have to be actively aligned with micron precision and submicron resolution. This will be done using beam-based algorithms which rely on beam position information inside of quadrupoles and accelerating structures. After a gener...

  8. Application of optical fiber beam loss monitor

    International Nuclear Information System (INIS)

    KEK is an accelerator complex consisting of an electron-positron injector linac and various types of circular accelerators. In order to protect instruments from radiation damage, discrete beam loss monitors have been installed inside the linac and rings. Although beam losses can be detected using the beam loss monitors (BLMs) or beam position monitors (BPMs), it is difficult to identify the exact position of the loss. The electrons, which strike the duct, lose a fraction of their beam energy, which produces a shower at the location and emits many electrons out of the duct. If an optical fiber is placed inside the beam duct, many of these electrons will pass through the optical fiber where the beam loss is generated. BLMs employing an optical fiber based on Cherenkov radiation are currently being developed and applied to our system. An optical fiber placed into the duct also can be used as a detector for a wire scanner system. Existing wire scanner detectors are set at a fixed position, and detect signals of different beam energies that correspond to the different injection modes. However, the fixed position is not always optimal. Conversely, owing to the optical fiber's distributing nature, optical fiber detector systems containing PMTs enables the effective detection of all signals from various beam modes. We can successfully obtain the clear wire scanner signal by employing this optical fiber system. The measurement of the beam loss at the incidence part of the circular accelerator is also described. The beam loss location as well as the turn-by-turn beam loss can be measured. (author)

  9. A Beam Shape Oscillation Monitor for HERA

    International Nuclear Information System (INIS)

    The perfect matching of the injecting beam phase space with the accelerator lattice is a very important problem. Its successful solution allows excluding possible mismatch emittance blow-up and worsening of the beam characteristics, that is necessary to get the highest possible luminosity in hadron accelerators. The mismatch can be controlled by measuring sizes oscillation on the first revolutions of the injected beam at a certain orbit point. Designed for this purpose the construction, acquisition electronics, software controlling of the operation and data processing of such a monitor are described. A first test result with beam is presented

  10. A Beam Shape Oscillation Monitor for HERA

    Science.gov (United States)

    Afanasyev, O. V.; Baluev, A. B.; Gubrienko, K. I.; Merker, E. A.; Wittenburg, K.; Krouptchenkow, I.

    2006-11-01

    The perfect matching of the injecting beam phase space with the accelerator lattice is a very important problem. Its successful solution allows excluding possible mismatch emittance blow-up and worsening of the beam characteristics, that is necessary to get the highest possible luminosity in hadron accelerators. The mismatch can be controlled by measuring sizes oscillation on the first revolutions of the injected beam at a certain orbit point. Designed for this purpose the construction, acquisition electronics, software controlling of the operation and data processing of such a monitor are described. A first test result with beam is presented.

  11. Nondestructive synchronous beam current monitor

    International Nuclear Information System (INIS)

    A fast current transformer is mounted after the deflectors of the Berkeley 88-Inch Cyclotron. The measured signal is amplified and connected to the input of a lock-in amplifier. The lock-in amplifier performs a synchronous detection of the signal at the cyclotron second harmonic frequency. The magnitude of the signal detected is calibrated against a Faraday cup and corresponds to the beam intensity. It has exceptional resolution, long term stability, and can measure the beam current leaving the cyclotron as low as 1 nA

  12. Realization of a scanning ion beam monitor

    International Nuclear Information System (INIS)

    During this thesis, a scanning ion beam monitor has been developed in order to measure on-line fluence spatial distributions. This monitor is composed of an ionization chamber, Hall Effect sensors and a scintillator. The ionization chamber set between the beam exit and the experiment measures the ion rate. The beam spot is localized thanks to the Hall Effect sensors set near the beam sweeping magnets. The scintillator is used with a photomultiplier tube to calibrate the ionization chamber and with an imaging device to calibrate the Hall Effect sensors. This monitor was developed to control the beam lines of a radiobiology dedicated experimentation room at GANIL. These experiments are held in the context of the research in hadron-therapy. As a matter of fact, this new cancer treatment technique is based on ion irradiations and therefore demands accurate knowledge about the relation between the dose deposit in biological samples and the induced effects. To be effective, these studies require an on-line control of the fluence. The monitor has been tested with different beams at GANIL. Fluence can be measured with a relative precision of ±4% for a dose rate ranging between 1 mGy/s and 2 Gy/s. Once permanently set on the beam lines dedicated to radiobiology at GANIL, this monitor will enable users to control the fluence spatial distribution for each irradiation. The scintillator and the imaging device are also used to control the position, the spot shape and the energy of different beams such as those used for hadron-therapy. (author)

  13. Quality assurance in individual monitoring

    International Nuclear Information System (INIS)

    Measurement and assessment of radiation dose to the individual radiation worker, called 'Individual monitoring', is one of the most important aspects of radiation protection. International Commission on Radiation Protection (ICRP-75) has outlined three main objectives of personal monitoring viz assessment of the effectively equivalent dose to demonstrate compliance with managerial and regulatory requirements; to contribute to control of operation and design of facilities and in case of accidental overexposure, to provide valuable information for the initiation and support of any health surveillance and treatment. To meet these objectives, it is essential that the measurements are reliable and accurate as defined by National and International Standards. This requires setting up of well defined internal as well as external quality assurance protocol in the individual monitoring program. External quality assurance program is meant to provide a reliable and qualitative as well as quantitative assessment of the service provided by the service provider. In India, individual monitoring is based on CaSO4:Dy based TLD badge and the task of conducting external quality assurance (QA) is being performed by RP and AD, Bhabha Atomic Research Centre. The paper presents the methodology of Quality assurance, Performance evaluation standards and criteria. It discusses the results and important observations of last few QA cycles conducted for all the TLD Labs. The quality assurance check has indicated that the performance of all the Labs is satisfactory in accordance with ANSI as well as Trumpet curve methodology. It provided feedback on further improvements in the quality

  14. Cryogenic Beam Loss Monitoring for the LHC

    CERN Document Server

    Kurfuerst, C; Sapinski, M

    A Beam Loss Monitoring (BLM) system was installed on the outside surface of the LHC magnet cryostats to protect the accelerator equipment from beam losses. The protection is achieved by extracting the beam from the ring in case thresholds imposed on measured radiation levels are exceeded. Close to the interaction regions of the LHC, the present BLM system is sensitive to particle showers generated in the interaction region of the two beams. In the future, with beams of higher energy and brightness resulting in higher luminosity, distinguishing between these interaction products and possible quench-provoking beam losses from the primary proton beams will be challenging. The particle showers measured by the present BLM configuration are partly shielded by the cryostat and the iron yoke of the magnets. The system can hence be optimised by locating beam loss monitors as close as possible to the protected element, i. e. the superconducting coils, inside the cold mass of the magnets in superfluid helium at 1.9 K. T...

  15. Monitoring external beam radiotherapy using real-time beam visualization

    International Nuclear Information System (INIS)

    Purpose: To characterize the performance of a novel radiation therapy monitoring technique that utilizes a flexible scintillating film, common optical detectors, and image processing algorithms for real-time beam visualization (RT-BV). Methods: Scintillating films were formed by mixing Gd2O2S:Tb (GOS) with silicone and casting the mixture at room temperature. The films were placed in the path of therapeutic beams generated by medical linear accelerators (LINAC). The emitted light was subsequently captured using a CMOS digital camera. Image processing algorithms were used to extract the intensity, shape, and location of the radiation field at various beam energies, dose rates, and collimator locations. The measurement results were compared with known collimator settings to validate the performance of the imaging system. Results: The RT-BV system achieved a sufficient contrast-to-noise ratio to enable real-time monitoring of the LINAC beam at 20 fps with normal ambient lighting in the LINAC room. The RT-BV system successfully identified collimator movements with sub-millimeter resolution. Conclusions: The RT-BV system is capable of localizing radiation therapy beams with sub-millimeter precision and tracking beam movement at video-rate exposure

  16. Monitoring external beam radiotherapy using real-time beam visualization

    Energy Technology Data Exchange (ETDEWEB)

    Jenkins, Cesare H. [Department of Mechanical Engineering and Department of Radiation Oncology, Stanford University, Stanford, California 94305 (United States); Naczynski, Dominik J.; Yu, Shu-Jung S.; Xing, Lei, E-mail: lei@stanford.edu [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California 94305 (United States)

    2015-01-15

    Purpose: To characterize the performance of a novel radiation therapy monitoring technique that utilizes a flexible scintillating film, common optical detectors, and image processing algorithms for real-time beam visualization (RT-BV). Methods: Scintillating films were formed by mixing Gd{sub 2}O{sub 2}S:Tb (GOS) with silicone and casting the mixture at room temperature. The films were placed in the path of therapeutic beams generated by medical linear accelerators (LINAC). The emitted light was subsequently captured using a CMOS digital camera. Image processing algorithms were used to extract the intensity, shape, and location of the radiation field at various beam energies, dose rates, and collimator locations. The measurement results were compared with known collimator settings to validate the performance of the imaging system. Results: The RT-BV system achieved a sufficient contrast-to-noise ratio to enable real-time monitoring of the LINAC beam at 20 fps with normal ambient lighting in the LINAC room. The RT-BV system successfully identified collimator movements with sub-millimeter resolution. Conclusions: The RT-BV system is capable of localizing radiation therapy beams with sub-millimeter precision and tracking beam movement at video-rate exposure.

  17. Fast-response beam loss monitor

    International Nuclear Information System (INIS)

    By connecting a polyethylene fiber to a photo-multiplier, a beam loss monitor with a fast response has been fabricated. The beam loss is measured by Cherenkov light generated by a charged particle penetrating a fiber. Although this monitor has the merits that the structure of the monitor is simple and cheap, it has the demerits that the signal has an energy dependence, and deterioration caused by radiation occurs. A plastic scintillating fiber and a quartz fiber have also been tested. The signal of the former fiber is strong and does not depend on the energy of the circulating beam. However, the deterioration is also very severe. On the contrary, the latter fiber has a long lifetime, though its signal is small. Some measurements are discussed here concerning various cases of extraction conditions. (author)

  18. BESSY Bragg-Fresnel multilayer beam monitors

    International Nuclear Information System (INIS)

    X-ray optical systems based on Bragg-Fresnel multilayer components imaging an electron beam in a storage ring with microm resolution are presented. Design concepts are compared to alternative methods, and the aberrations and limits of Bragg-Fresnel multilayer optics are discussed. Experimental results of imaging the BESSY 1 source with sub 10 microm resolution are presented and the development of a compact Bragg-Fresnel multilayer telescope as a BESSY 2 standard beam monitor is described

  19. The AGS Booster Beam Position Monitor system

    International Nuclear Information System (INIS)

    To accelerate both protons and heavy ions, the AGS Booster requires a broadband (multi-octave) beam position monitoring system with a dynamic range spanning several orders of magnitude (2 x 1010 to 1.5 x 1013 particles per pulse). System requirements include the ability to acquire single turn trajectory and average orbit information with ± 0.1 mm resolution. The design goal of ± 0.5 mm corrected accuracy requires that the detectors have repeatable linear performance after periodic bakeout at 300 degree C. The system design and capabilities of the Booster Beam Position Monitor will be described, and initial results presented. 7 refs., 5 figs

  20. Measuring emittance using beam position monitors

    International Nuclear Information System (INIS)

    The Los Alamos Advanced Free Electron Laser uses a high charge (greater than InC), low emittance (normalized rams emittance less than 5π mm mrad) photoinjector driven accelerator. The high brightness achieved is due, in large part, to the rapid acceleration of the electrons to relativistic velocities. As a result, the beam does not have time to thermalize its distribution and its universe profile is, in general, non-Gaussian. This, coupled with the very high brightness, makes it difficult to measure the transverse emittance. Techniques used must be able to withstand the rigors of very intense electron beams, and not be reliant on Gaussian assumptions. Beam position monitors are ideal for this. They are not susceptible to beam damage, and it has been shown previously that they can be used to measure the transverse emittance of a beam with a Gaussian profile. However, this Gaussian restriction is not necessary and, in fact, a transverse emittance measurement using beam position monitors is independent of the beam's distribution

  1. G0 beam quality and multiple linear regression corrections

    International Nuclear Information System (INIS)

    The G0 experiment measures parity-violating elastic e-p scattering asymmetries to probe the strange quark content of the nucleon. The goal is to measure the asymmetries with an overall uncertainty of 5% of the measured asymmetries which will be of order 10?5 to 10?6. In order to achieve the above precision, systematic effects which can induce false asymmetries must be controlled. One such systematic error is helicity-correlated changes in beam parameters, which, coupled with the sensitivity of the G0 spectrometer to such beam variations, can induce false asymmetries. Beam parameters monitored for helicity-correlation are beam current, beam position, beam angle, and beam energy. A feedback loop was successfully used to reduce the helicity-correlation in beam current and beam position. The sensitivity of the G0 spectrometer to fluctuations in beam parameters has also been measured, and the false asymmetries have been determined to be of order 10?8. This contribution will address the sensitivity of the G0 spectrometer to changes in beam conditions, the performance of the feedback loops as well as the resulting parity quality of the G0 beam, and the resulting false asymmetry

  2. G0 beam quality and multiple linear regression corrections

    International Nuclear Information System (INIS)

    The G0 experiment measures parity-violating elastic e-p scattering asymmetries to probe the strange quark content of the nucleon. The goal is to measure the asymmetries with an overall uncertainty of 5% of the measured asymmetries which will be of order 10-5 to 10-6. In order to achieve the above precision, systematic effects which can induce false asymmetries must be controlled. One such systematic error is helicity-correlated changes in beam parameters, which, coupled with the sensitivity of the G0 spectrometer to such beam variations, can induce false asymmetries. Beam parameters monitored for helicity-correlation are beam current, beam position, beam angle, and beam energy. A feedback loop was successfully used to reduce the helicity-correlation in beam current and beam position. The sensitivity of the G0 spectrometer to fluctuations in beam parameters has also been measured, and the false asymmetries have been determined to be of order 10-8. This contribution will address the sensitivity of the G0 spectrometer to changes in beam conditions, the performance of the feedback loops as well as the resulting parity quality of the G0 beam, and the resulting false asymmetry. (orig.)

  3. Beam Loss Monitors at LHC

    CERN Document Server

    Dehning, B

    2016-01-01

    One of the main functions of the LHC beam loss measurement system is the protection of equipment against damage caused by impacting particles creating secondary showers and their energy dissipation in the matter. Reliability requirements are scaled according to the acceptable consequences and the frequency of particle impact events on equipment. Increasing reliability often leads to more complex systems. The downside of complexity is a reduction of availability; therefore, an optimum has to be found for these conflicting requirements. A detailed review of selected concepts and solutions for the LHC system will be given to show approaches used in various parts of the system from the sensors, signal processing, and software implementations to the requirements for operation and documentation.

  4. Comment on 'Proton beam monitor chamber calibration'.

    Science.gov (United States)

    Palmans, Hugo; Vatnitsky, Stanislav M

    2016-09-01

    We comment on a recent article (Gomà et al 2014 Phys. Med. Biol. 59 4961-71) which compares different routes of reference dosimetry for the energy dependent beam monitor calibration in scanned proton beams. In this article, a 3% discrepancy is reported between a Faraday cup and a plane-parallel ionization chamber in the experimental determination of the number of protons per monitor unit. It is further claimed that similar discrepancies between calorimetry and ionization chamber based dosimetry indicate that [Formula: see text]-values tabulated for proton beams in IAEA TRS-398 might be overestimated. In this commentary we show, however, that this supporting argument misrepresents the evidence in the literature and that the results presented, together with published data, rather confirm that there exist unresolved problems with Faraday cup dosimetry. We also show that the comparison in terms of the number of protons gives a biased view on the uncertainty estimates for both detectors while the quantity of interest is absorbed dose to water or dose-area-product to water, even if a beam monitor is calibrated in terms of the number of protons. Gomà et al (2014 Phys. Med. Biol. 59 4961-71) also report on the discrepancy between cylindrical and plane-parallel ionization chambers and confirm experimentally that in the presence of a depth dose gradient, theoretical values of the effective point of measurement, or alternatively a gradient correction factor, account for the discrepancy. We believe this does not point to an error or shortcoming of IAEA TRS-398, which prescribes taking the centre of cylindrical ionization chambers as reference point, since it recommends reference dosimetry to be performed in the absence of a depth dose gradient. But these observations reveal that important aspects of beam monitor calibration in scanned proton beams are not addressed in IAEA TRS-398 given that those types of beams were not widely implemented at the time of its publication

  5. A beam radiation monitoring and protection system for AGS secondary beams

    International Nuclear Information System (INIS)

    A commercially available radiation monitor using a scintillation detector was modified for charged particle beam monitoring. The device controls access to secondary beams of the AGS and limits beam intensity

  6. Calibration of a proton beam energy monitor.

    Science.gov (United States)

    Moyers, M F; Coutrakon, G B; Ghebremedhin, A; Shahnazi, K; Koss, P; Sanders, E

    2007-06-01

    Delivery of therapeutic proton beams requires an absolute energy accuracy of +/-0.64 to 0.27 MeV for patch fields and a relative energy accuracy of +/-0.10 to 0.25 MeV for tailoring the depth dose distribution using the energy stacking technique. Achromatic switchyard tunes, which lead to better stability of the beam incident onto the patient, unfortunately limit the ability of switchyard magnet tesla meters to verify the correct beam energy within the tolerances listed above. A new monitor to measure the proton energy before each pulse is transported through the switchyard has been installed into a proton synchrotron. The purpose of this monitor is to correct and/or inhibit beam delivery when the measured beam energy is outside of the tolerances for treatment. The monitor calculates the beam energy using data from two frequency and eight beam position monitors that measure the revolution frequency of the proton bunches and the effective offset of the orbit from the nominal radius of the synchrotron. The new energy monitor has been calibrated by measuring the range of the beam through water and comparing with published range-energy tables for various energies. A relationship between depth dose curves and range-energy tables was first determined using Monte Carlo simulations of particle transport and energy deposition. To reduce the uncertainties associated with typical scanning water phantoms, a new technique was devised in which the beam energy was scanned while fixed thickness water tanks were sandwiched between two fixed parallel plate ionization chambers. Using a multitude of tank sizes, several energies were tested to determine the nominal accelerator orbit radius. After calibration, the energy reported by the control system matched the energy derived by range measurements to better than 0.72 MeV for all nine energies tested between 40 and 255 MeV with an average difference of -0.33 MeV. A study of different combinations of revolution frequency and radial

  7. Laser Wire and Beam Position Monitor tests

    CERN Document Server

    Boogert, S T; Lyapin, A; Nevay, L; Snuverink, J

    2013-01-01

    This subtask involved two main activities; Firstly the development and subsequent usage of high resolution beam position monitors (BPM) for the International Linear Collider (ILC) and Compact Linear Collider projects (CLIC); and secondly the development of a laser-wire (LW) transverse beam size measurement systems. This report describes the technical progress achieved at a large-scale test ILC compatible BPM system installed at the Accelerator Test Facility 2 (ATF2). The ATF2 is an energy-scaled demonstration system for the final focus systems required to deliver the particle beams to collision at the ILC and CLIC. The ATF2 cavity beam position monitor system is one of the largest of its kind and rivals systems used at free electron lasers. The ATF2 cavity beam position system has achieved a position resolutionof 250 nm (with signal attuenation) and 27 nm (without attenuation). The BPM system has been used routinely for lattice diagnostics, beam based alignment and wakefield measurements. Extensive experience...

  8. A calibration procedure for beam monitors in a scanned beam of heavy charged particles.

    Science.gov (United States)

    Jäkel, O; Hartmann, G H; Karger, C P; Heeg, P; Vatnitsky, S

    2004-05-01

    An international code of practice (CoP) for dosimetry based on standards of absorbed dose to water has recently been published by the IAEA [Technical Report Series No. 398, 2000] (TRS-398). This new CoP includes procedures for proton and heavy ion beams as well as all other beam qualities. In particular it defines reference conditions to which dose measurements should refer to. For proton and ion beams these conditions include dose measurements in the center of all possible modulated Bragg peaks. The recommended reference conditions in general are used also for the calibration of beam monitors. For a dynamic beam delivery system using beam scanning in combination with energy variation, like, e.g., at the German carbon ion radiotherapy facility, this calibration procedure is not appropriate. We have independently developed a different calibration procedure. Similar to the IAEA CoP this procedure is based on the measurement of absorbed dose to water. This is translated in terms of fluence which finally results in an energy-dependent calibration of the beam monitor in units of particle number per monitor unit, which is unique for all treatment fields. In contrast to the IAEA CoP, the reference depth is chosen to be very small. The procedure enables an accurate and reliable determination of calibration factors. In a second step, the calibration is verified by measurements of absorbed dose in various modulated Bragg peaks by comparing measured against calculated doses. The agreement between measured and calculated doses is usually better than 1% for homogeneous fields and the mean deviation for more inhomogeneous treatment fields, as they are used for patient treatments, is within 3%. It is proposed that the CoP in general, and in particular the IAEA TRS-398 should include explicit recommendations for the beam monitor calibration. These recommendations should then distinguish between systems using static and dynamic beams. PMID:15191285

  9. Columbia River water quality monitoring

    International Nuclear Information System (INIS)

    Waste water from Hanford activities is discharged at eight points along the Hanford reach of the Columbia River. These discharges consist of backwash water from water intake screens, cooling water, river bank springs, water storage tank overflow, and fish laboratory waste water. Each discharge point is identified in an existing National Pollutant Discharge Elimination System (NPDES) permit issued by the EPA. Effluents from each of these outfalls are routinely monitored and reported by the operating contractors as required by their NPDES permits. Measurements of several Columbia River water quality parameters were conducted routinely during 1982 both upstream and downstream of the Hanford Site to monitor any effects on the river that may be attributable to Hanford discharges and to determine compliance with the Class A designation requirements. The measurements indicated that Hanford operations had a minimal, if any, impact on the quality of the Columbia River water

  10. BESSY Bragg-Fresnel multilayer beam monitors

    International Nuclear Information System (INIS)

    X-ray optical systems based on Bragg-Fresnel multilayer components imaging an electron beam in a storage ring with μm resolution are presented. Design concepts are compared to alternative methods, and the aberrations and limits of Bragg-Fresnel multilayer optics are discussed. Experimental results of imaging the BESSY I source with sub-10-μm resolution are presented, and the development of a compact Bragg-Fresnel multilayer telescope as a BESSY II standard beam monitor is described. copyright 1996 American Institute of Physics

  11. Beam monitoring in radiotherapy and hadron-therapy

    International Nuclear Information System (INIS)

    Radiotherapy techniques have evolved over the past twenty years. For photon beams, the development of tools such as multi leaf collimators, machines such as Cyberknife or tomo-therapy, have improved the conformation of treatments to the tumor volume and lowered maximum dose to healthy tissue. In another register, the use of proton-therapy is expanding in all countries and the development of carbon ions beams for hadron-therapy is also increasing. If techniques improve, the control requirements for the monitoring of the dose administered to patients are always the same. This document presents, first, the ins and outs of the different techniques of external beam radiotherapy: photon treatments, protons and hadrons. Starting from the basis of clinical requirements, it sets the variables to be measured in order to ensure the quality of treatment for the different considered modalities. It then describes some implementations, based on precise and rigorous specifications, for the monitoring and measurement of beams delivered by external beam radiotherapy equipments. Two instrumental techniques are particularly highlighted, plastic scintillators dosimetry for the control of megavoltage photon beams and ionization chamber dosimetry applied to proton-therapy or radiobiology experiments conducted at the GANIL facility. Analyzes and perspectives, based on the recent developments of treatment techniques, are delivered in conclusion and can serve as guide for future instrumental developments. (author)

  12. A high resolution, single bunch, beam profile monitor

    International Nuclear Information System (INIS)

    Efficient linear colliders require very small beam spots to produce high luminosities with reasonable input power, which limits the number of electrons which can be accelerated to high energies. The small beams, in turn, require high precision and stability in all accelerator components. Producing, monitoring and maintaining beams of the required quality has been, and will continue to be, difficult. A beam monitoring system which could be used to measure beam profile, size and stability at the final focus of a beamline or collider has been developed and is described here. The system uses nonimaging bremsstrahlung optics. The immediate use for this system would be examining the final focus spot at the SLAC/FFTB. The primary alternatives to this technique are those proposed by P. Chen / J. Buon, which analyses the energy and angular distributions of ion recoils to determine the aspect ratio of the electron bunch, and a method proposed by Shintake, which measures intensity variation of compton backscattered photons as the beam is moved across a pattern of standing waves produced by a laser

  13. Beam position monitoring electronics system for LEHIPA

    International Nuclear Information System (INIS)

    The primary function of beam position monitoring system (BPM) is to determine the position of the beam with respect to the centre of beam pipe. The present system is VME based and mainly consists of two VME boards one Analog and one Digital. The system has been developed for 352.21 MHz Low Energy High Intensity Proton Accelerator (LEHIPA). The electronic system processes the signals coming from the sensor which incorporates four button pick-ups placed orthogonally around the beam pipe. The fundamental component of the beam signal is extracted from the signals from the sensor and amplified with gain stabilized amplifiers on the analog board. Offset tone based technique has been used for the stabilization of the gain of the amplifiers against changes in temperature, power supply, etc. The filtered and amplified signals are given to the digital board for digitization and further processing. The signal processing consists of demodulation in I-Q domain followed by CORDIC which gives the signal information in the form of amplitude and phase. The stabilization of the gain is also carried out in the digital domain. The phase information can be utilized for energy gain measurements. The amplitudes give the position of the beam which is calculated online in FPGA using difference over sum method. The EPICS system has been chosen as the basic framework for command control. The hardware architecture is as per standard VME crate. (author)

  14. Development of beam position monitor for test beam of BEPC II

    International Nuclear Information System (INIS)

    Three stripline beam position monitors and some feed-throughs were developed to measure the position of beam non-interceptively in test beam facility. After three stripline beam position monitors were produced, calibrations of the monitors were carried out on a workbench, which has high precision and is controlled by a computer. Then two monitor's were installed at the beam line and some experiments were carried out. Four 1 mm thickness stainless steel strips are main modules of the monitor, signals induced in these strips reflect the position of the beam bunch. Calibration coefficient, system characteristic impedance and port transmission coefficient of monitor are introduced in this paper. (authors)

  15. APCAL1: Beam Position Monitor Program

    International Nuclear Information System (INIS)

    APCAL1 is an applications program operational on the PEP MODCOMP IV computer for the purpose of converting beam position monitor (BPM) button voltage readings to x,y coordinates. Calibration information and the BPM readings are read from the MODCOMP IV data base. Corresponding x,y coordinates are written in the data base for use by other programs. APCAL1 is normally activated by another program but can be activated by a touch panel for checkout purposes

  16. Monitoring the beam position in the SLC interaction region

    International Nuclear Information System (INIS)

    The Stanford Linear Collider requires special Beam Position Monitors near the Interaction Point (IP) to bring the two beams (e+ and e-) into collision. These beams pass through two monitors on each side of the IP with a short time separation (about 20 and 50 ns). The mechanics of the monitors as well as the electronics will be described. In order to bring beams of several microns diameter into collision at the IP, these monitors measure beam deflection induced by the presence of the opposite beam

  17. Quality assurance for particle beam therapy

    International Nuclear Information System (INIS)

    In radiation therapy, it is essential that a prescribed target area is irradiated with the prescribed dose concentration to reduce the possibility cancer reoccurrence or to mitigate its side effects. Particle beam therapy is a high accuracy radiation therapy, which has superior characteristics. Specifically, a high dose region, namely, Bragg peak formed around the beam stopping point can be adjusted to the target volume. The routine of particle beam therapy should be performed with various verifications, called quality assurance(QA), at its each step, i.e., treatment planning, dosimetry, patient positioning and respiratory gating system. Each particle beam therapy facility should have and conduct its own QA program. Methods and materials for the QA should be developed according to the progress of techniques in particle beam therapy. (author)

  18. The ATLAS Diamond Beam Monitor : Luminosity Detector on the LHC

    CERN Document Server

    Schaefer, Douglas; The ATLAS collaboration

    2015-01-01

    After the first three years of the LHC running the ATLAS experiment extracted it's pixel detector system to refurbish and re-position the optical readout drivers and install a new barrel layer of pixels. The experiment has also taken advantage of this access to also install a set of beam monitoring telescopes with pixel sensors, four each in the forward and backward regions. These telescopes were assembled based on chemical vapour deposited (CVD) diamond sensors to survive in this high radiation environment without needing extensive cooling. This talk will describe the lessons learned in construction and commissioning of the ATLAS x Diamond Beam Monitor (DBM). We will show results from the construction quality assurance tests, commissioning performance, including results from cosmic ray running in early 2015 and also expected first results from LHC run 2 collisions.

  19. The ATLAS Diamond Beam Monitor: Luminosity detector at the LHC

    Science.gov (United States)

    Schaefer, D. M.

    2016-07-01

    After the first three years of the LHC running, the ATLAS experiment extracted its pixel detector system to refurbish and re-position the optical readout drivers and install a new barrel layer of pixels. The experiment has also taken advantage of this access to install a set of beam monitoring telescopes with pixel sensors, four each in the forward and backward regions. These telescopes are based on chemical vapor deposited (CVD) diamond sensors to survive in this high radiation environment without needing extensive cooling. This paper describes the lessons learned in construction and commissioning of the ATLAS Diamond Beam Monitor (DBM). We show results from the construction quality assurance tests and commissioning performance, including results from cosmic ray running in early 2015.

  20. LHC Injection Beam Quality During LHC Run I

    CERN Document Server

    AUTHOR|(CDS)2079186; Stapnes, Steinar

    The LHC at CERN was designed to accelerate proton beams from 450 GeV to 7 TeV and collide them in four large experiments. The 450 GeV beam is extracted from the last pre-accelerator, the SPS, and injected into the LHC via two 3 km long transfer lines, TI 2 and TI 8. The injection process is critical in terms of preservation of beam quality and machine protection. During LHC Run I (2009-2013) the LHC was filled with twelve high intensity injections per ring, in batches of up to 144 bunches of 1.7*10^11 protons per bunch. The stored beam energy of such a batch is already an order of magnitude above the damage level of accelerator equipment. Strict quality and machine protection requirements at injection have a significant impact on operational efficiency. During the first years of LHC operation, the injection phase was identified as one of the limiting factors for fast LHC turnaround time. The LHC Injection Quality Check (IQC) software framework was developed as a part of this thesis to monitor the beam quality...

  1. Performance and perspectives of the diamond based Beam Condition Monitor for beam loss monitoring at CMS

    CERN Document Server

    AUTHOR|(CDS)2080862

    2015-01-01

    At CMS, a beam loss monitoring system is operated to protect the silicon detectors from high particle rates, arising from intense beam loss events. As detectors, poly-crystalline CVD diamond sensors are placed around the beam pipe at several locations inside CMS. In case of extremely high detector currents, the LHC beams are automatically extracted from the LHC rings.Diamond is the detector material of choice due to its radiation hardness. Predictions of the detector lifetime were made based on FLUKA monte-carlo simulations and irradiation test results from the RD42 collaboration, which attested no significant radiation damage over several years.During the LHC operational Run1 (2010 â?? 2013), the detector efficiencies were monitored. A signal decrease of about 50 times stronger than expectations was observed in the in-situ radiation environment. Electric field deformations due to charge carriers, trapped in radiation induced lattice defects, are responsible for this signal decrease. This so-called polarizat...

  2. RHIC beam loss monitor system design

    International Nuclear Information System (INIS)

    The Beam Loss Monitor (BLM) System is designed to prevent the quenching of RHIC magnets due to beam loss, provide quantitative loss data, and the loss history in the event of a beam abort. The system uses 400 ion chambers of a modified Tevatron design. To satisfy fast (single turn) and slow (100 msec) loss beam criteria and provide sensitivity for studies measurements, a range of over 8 decades is needed. An RC pre-integrator reduces the dynamic range for a low current amplifier. This is digitized for data logging. The output is also applied to an analog multiplier which compensates the energy dependence, extending the range of the abort comparators. High and low pass filters separate the signal to dual comparators with independent programmable trip levels. Up to 64 channels, on 8 VME boards, are controlled by a micro-controller based VME module, decoupling it from the front-end computer (FEC) for real-time operation. Results with the detectors in the RHIC Sextant Test and the electronics in the AGS-to-RHIC (AtR) transfer line will be presented

  3. Beam loss monitor system for the SSC

    International Nuclear Information System (INIS)

    At full intensity the energy contained in each beam of the Superconducting Super Collider (SSC) is 400 MJ. The loss of a small fraction of that beam has the potential to cause magnet quenches or even severe damage to Collider components. To help protect the machine a sensitive and reliable beam loss monitor (BLM) system must be designed and built. In fact, BLM systems will be needed for all the accelerators of the SSC. The BLM system requirements for each of these accelerators will be discussed, but emphasis will be placed on the Collider. The discussion will include the preliminary design of BLM systems, the considerations that led to these designs, the calculations that were performed in development of the designs, and the problems that remain to be solved. A major tool in the design process has been a series of Monte Carlo calculations that were used to estimate beam loss distributions for the Collider arcs, the interaction regions, and the west utility region. These calculations were also used to study the fluence as a function of energy, the particle content, and the dose rate at selected positions. Detailed considerations such as detector spacing and sensitivity, loss fluctuations, reliability, and maintainability will be discussed. The proposed preliminary BLM system design for the Collider uses a radiation-hard, solid-state ionization detector and fast analog-to-digital conversion. Details of this design and relevant options will be discussed

  4. Signal Processing for Beam Position Monitors

    CERN Document Server

    Vismara, Giuseppe

    2000-01-01

    At the first sight the problem to determine the beam position from the ratio of the induced charges of the opposite electrodes of a beam monitor seems trivial, but up to now no unique solution has been found that fits the various demands of all particle accelerators. The purpose of this paper is to help "instrumentalists" to choose the best processing system for their particular application, depending on the machine size, the input dynamic range, the required resolution and the acquisition speed. After a general introduction and an analysis of the electrical signals to be treated (frequency and time domain), the definition of the electronic specifications will be reviewed. The tutorial will present the different families in which the processing systems can be grouped. A general description of the operating principles with relative advantages and disadvantages for the most employed processing systems is presented. Special emphasis will be put on recent technological developments based on telecommunication circ...

  5. The AGS Booster beam loss monitor system

    International Nuclear Information System (INIS)

    A beam loss monitor system has been developed for the Brookhaven National Laboratory Booster accelerator, and is designed for use with intensities of up to 1.5 x 1013 protons and carbon to gold ions at 50-3 x 109 ions per pulse. This system is a significant advance over the present AGS system by improving the sensitivity, dynamic range, and data acquisition. In addition to the large dynamic range achievable, it is adaptively shifted when high losses are detected. The system uses up to 80 argon filled ion chambers as detectors, as well as newly designed electronics for processing and digitizing detector outputs. The hardware simultaneously integrates each detector output, interfaces to the beam interrupt systems, and digitizes all 80 channels to 21 bits at 170 KHz. This paper discuses the design, construction, and operation of the system. 4 refs., 2 figs

  6. First Experiences of Beam Presence Detection Based on Dedicated Beam Position Monitors

    CERN Document Server

    Jalal, A; Gasior, M; Todd, B

    2011-01-01

    High intensity particle beam injection into the LHC is only permitted when a low intensity pilot beam is already circulating in the LHC. This requirement addresses some of the risks associated with high intensity injection, and is enforced by a so-called Beam Presence Flag (BPF) system which is part of the interlock chain between the LHC and its injector complex. For the 2010 LHC run, the detection of the presence of this pilot beam was implemented using the LHC Fast Beam Current Transformer (FBCT) system. However, the primary function of the FBCTs, that is reliable measurement of beam currents, did not allow the BPF system to satisfy all quality requirements of the LHC Machine Protection System (MPS). Safety requirements associated with high intensity injections triggered the development of a dedicated system, based on Beam Position Monitors (BPM). This system was meant to work first in parallel with the FBCT BPF system and eventually replace it. At the end of 2010 and in 2011, this new BP...

  7. New detector for neutron beam monitor

    International Nuclear Information System (INIS)

    In order to obtain high precision in neutron cross-section measurements, an essential aspect is the accurate knowledge of the energy distribution of the neutron flux during the measurements. The detector dedicated to this measurement should measure the neutron flux impinging on the sample placed in the beam; therefore it should be placed upstream of the sample position and of the different detectors in the measurement area. As a consequence of that, such a flux detector should ideally have an in-beam mass as small as possible in order to minimize the perturbation on the neutron beam and to minimize the production of background by the device itself. According to these considerations a new neutron detector equipped with a small-mass device based on Micromegas micro-bulk technology has been designed for monitoring the CERN nTOF neutron beam. In order to cover the full range of the neutron energy from thermal to several MeV, two neutron/charged particle converters (235U and 10B) have been used. The 235U(n,f) is suited above a few 100 eV. Below that energy the resonance structure of 235U(n,f) does not allow a precise determination of the neutron flux without taking into account detailed and complicated corrections. To overcome this issue the 10B(n,α) reaction is simultaneously used. After a description of the innovative detector concept, we present the result obtained at the GELINA neutron beam facility of JRC-IRMM Geel, and the preliminary results from the commissioning of the new target of the CERN nTOF facility. (author)

  8. Subjective video quality comparison of HDTV monitors

    Science.gov (United States)

    Seo, G.; Lim, C.; Lee, S.; Lee, C.

    2009-01-01

    HDTV broadcasting services have become widely available. Furthermore, in the upcoming IPTV services, HDTV services are important and quality monitoring becomes an issue, particularly in IPTV services. Consequently, there have been great efforts to develop video quality measurement methods for HDTV. On the other hand, most HDTV programs will be watched on digital TV monitors which include LCD and PDP TV monitors. In general, the LCD and PDP TV monitors have different color characteristics and response times. Furthermore, most commercial TV monitors include post-processing to improve video quality. In this paper, we compare subjective video quality of some commercial HD TV monitors to investigate the impact of monitor type on perceptual video quality. We used the ACR method as a subjective testing method. Experimental results show that the correlation coefficients among the HDTV monitors are reasonable high. However, for some video sequences and impairments, some differences in subjective scores were observed.

  9. An interactive beam position monitor system simulator

    International Nuclear Information System (INIS)

    A system simulator has been implemented to aid the development of the RHIC position monitor system. Based on the LabVIEW software package by National Instruments, this simulator allows engineers and technicians to interactively explore the parameter space of a system during the design phase. Adjustable parameters are divided into three categories: beam, pickup, and electronics. The simulator uses these parameters in simple formulas to produce results in both time-domain and frequencydomain. During the prototyping phase, these simulated results can be compared to test data acquired with the same software package. The RHIC position monitor system is presented as an example, but the software is applicable to several other systems as well

  10. ATLAS Offline Data Quality Monitoring

    CERN Document Server

    Adelman, J; Boelaert, N; D'Onofrio, M; Frost, J A; Guyot, C; Hauschild, M; Hoecker, A; Leney, K J C; Lytken, E; Martinez-Perez, M; Masik, J; Nairz, A M; Onyisi, P U E; Roe, S; Schatzel, S; Schaetzel, S; Wilson, M G

    2010-01-01

    The ATLAS experiment at the Large Hadron Collider reads out 100 Million electronic channels at a rate of 200 Hz. Before the data are shipped to storage and analysis centres across the world, they have to be checked to be free from irregularities which render them scientifically useless. Data quality offline monitoring provides prompt feedback from full first-pass event reconstruction at the Tier-0 computing centre and can unveil problems in the detector hardware and in the data processing chain. Detector information and reconstructed proton-proton collision event characteristics are distilled into a few key histograms and numbers which are automatically compared with a reference. The results of the comparisons are saved as status flags in a database and are published together with the histograms on a web server. They are inspected by a 24/7 shift crew who can notify on-call experts in case of problems and in extreme cases signal data taking abort.

  11. The CMS Beam Halo Monitor Electronics

    CERN Document Server

    Tosi, Nicolo

    2015-01-01

    The CMS Beam Halo Monitor has been successfully installed in the CMS cavern in LHC Long Shutdown 1 for measuring the machine induced background for LHC Run II. The system is based on 40 detector units composed of synthetic quartz Cherenkov radiators coupled to fast photomultiplier tubes. The readout electronics chain uses many components developed for the Phase 1 upgrade to the CMS Hadronic Calorimeter electronics, with dedicated firmware and readout adapted to the beam monitoring requirements. The PMT signal is digitized by a charge integrating ASIC (QIE10), providing both the signal rise time, with few ns resolution, and the charge integrated over one bunch crossing. The backend electronics uses microTCA technology and receives data via a high-speed 5 Gbps asynchronous link. It records histograms with sub-bunch crossing timing resolution and is readout by IPbus using the newly designed CMS data acquisition for non-event based data. The data is processed in real time and published to CMS and the LHC, provid...

  12. Performance of the CMS Beam Halo Monitor

    CERN Document Server

    CMS Collaboration

    2015-01-01

    The CMS Beam Halo Monitor has been successfully installed in the CMS cavern in LHC Long Shutdown 1 for measuring the machine induced background for LHC Run II. The system is based on 40 detector units composed of radiation hard synthetic quartz Cherenkov radiators coupled to fast photomultiplier tubes for a direction sensitive measurement. The readout electronics chain uses many components developed for the Phase 1 upgrade to the CMS Hadronic Calorimeter electronics, with dedicated firmware and readout adapted to the beam monitoring requirements. The PMT signal is digitized by a charge integrating ASIC (QIE10), providing both the signal rise time, with few ns resolution, and the charge integrated over one bunch crossing. The backend electronics uses microTCA technology and received data via a high-speed 5 Gbps asynchronous link. It records histograms with sub-bunch crossing timing resolution and is readout by IPbus using the newly designed CMS data acquisition for non-event based data. The data is processed i...

  13. Statistical Treatment of Beam Position Monitor Data

    CERN Document Server

    Reiter, Andreas; Chorniy, Oleksandr

    2016-01-01

    We review beam position monitors adopting the perspective of an analogue-to- digital converter in a sampling data acquisition system. From a statistical treatment of independent data samples we derive basic formulae of position uncertainty for beam position monitors. Uncertainty estimates only rely on a few simple model parameters and have been calculated for two "practical" signal shapes, a square pulse and a triangular pulse. The analysis has been carried out for three approaches: the established signal integration and root-sum-square ap- proaches, and a least-square fit for the models of direct proportion and straight-line. The latter approach has not been reported in the literature so far. The straight-line fit provides the most robust estimator since it does not require baseline restoration, it is immune to signal offsets, and its standard deviation is smallest. Consequently, of the analysed estimators it promises the highest fidelity of results. The fit approach represents a simple, natural way to analy...

  14. Design of CMS Beam Halo Monitor system

    CERN Document Server

    AUTHOR|(CDS)2078842

    2015-01-01

    A fast and directional monitoring system for the CMS experiment is designed to provide an online, bunch-by-bunch measurement of beam background induced by beam halo interactions, separately for each beam. The background detection is based on Cherenkov radiation produced in synthetic fused silica read out by a fast, UV sensitive photomultiplier tube. Twenty detector units per end will be azimuthally distributed around the rotating shielding of CMS, covering ~408 cm2 at 20.6m from the interaction point, at a radius of ~180 cm. The directional and fast response of the system allows the discrimination of the background particles from the dominant flux in the cavern induced by pp collision debris, produced within the 25 ns bunch spacing. A robust multi-layered shielding will enclose each detector unit to protect the photomultiplier tube from the magnetic field and to eliminate the occupancy from low energy particles. The design of the front-end units is validated by experimental results. An overview of the new sy...

  15. Cryogenic beam loss monitoring for the LHC

    International Nuclear Information System (INIS)

    A Beam Loss Monitoring (BLM) system was installed on the outside surface of the LHC magnet cryostats to protect the accelerator equipment from beam losses. The protection is achieved by extracting the beam from the ring in case thresholds imposed on measured radiation levels are exceeded. Close to the interaction regions of the LHC, the present BLM system is sensitive to particle showers generated in the interaction region of the two beams. In the future, with beams of higher energy and brightness resulting in higher luminosity, distinguishing between these interaction products and possible quench-provoking beam losses from the primary proton beams will be challenging. The particle showers measured by the present BLM configuration are partly shielded by the cryostat and the iron yoke of the magnets. The system can hence be optimised by locating beam loss monitors as close as possible to the protected element, i. e. the superconducting coils, inside the cold mass of the magnets in superfluid helium at 1.9 K. The advantage is that the dose measured by the Cryogenic Beam Loss Monitor (CryoBLM) would more precisely correspond to the dose deposited in the superconducting coil. The main challenges of this placement are the low temperature of 1.9 K and the integrated dose of 2 MGy in 20 years. Furthermore the CryoBLM should work in a magnetic field of 2 T and at a pressure of 1.1 bar, withstanding a fast pressure rise up to 20 bar in case of a magnet quench. The detector response should be linear between 0.1 and 10 mGy/s and faster than 1 ms. Once the detectors are installed in the LHC magnets, no access will be possible. Hence the detectors need to be available, reliable and stable for 20 years. Following intense research it became clear that no existing technology was proven to work in such conditions. The candidates under investigation in this work are diamond and silicon detectors and an ionisation chamber, using the liquid helium itself as particle detection medium

  16. Beam-beam deflection and beamstrahlung monitor response for tilted elliptic beams

    International Nuclear Information System (INIS)

    At the interaction point of the SLC two oppositely running bunches with energies of 46 GeV and transverse extensions of a few microns are brought into collision. The strong electron and magnetic fields produced by one bunch lead to a deflection of the other bunch and to the emission of synchrotron radiation of critical energies of a few 10 MeV. This radiation, coined beamstrahlung, is detected in a Cerenkov monitor. In this paper a simulation code for the beam-beam interaction of two tilted elliptic beams is presented. A closed expression for the deflection angles is presented and the number of generated Cerenkov photons is calculated

  17. Demonstration of the importance of a dedicated neutron beam monitoring system for BNCT facility.

    Science.gov (United States)

    Chao, Der-Sheng; Liu, Yuan-Hao; Jiang, Shiang-Huei

    2016-01-01

    The neutron beam monitoring system is indispensable to BNCT facility in order to achieve an accurate patient dose delivery. The neutron beam monitoring of a reactor-based BNCT (RB-BNCT) facility can be implemented through the instrumentation and control system of a reactor provided that the reactor power level remains constant during reactor operation. However, since the neutron flux in reactor core is highly correlative to complicated reactor kinetics resulting from such as fuel depletion, poison production, and control blade movement, some extent of variation may occur in the spatial distribution of neutron flux in reactor core. Therefore, a dedicated neutron beam monitoring system is needed to be installed in the vicinity of the beam path close to the beam exit of the RB-BNCT facility, where it can measure the BNCT beam intensity as closely as possible and be free from the influence of the objects present around the beam exit. In this study, in order to demonstrate the importance of a dedicated BNCT neutron beam monitoring system, the signals originating from the two in-core neutron detectors installed at THOR were extracted and compared with the three dedicated neutron beam monitors of the THOR BNCT facility. The correlation of the readings between the in-core neutron detectors and the BNCT neutron beam monitors was established to evaluate the improvable quality of the beam intensity measurement inferred by the in-core neutron detectors. In 29 sampled intervals within 16 days of measurement, the fluctuations in the mean value of the normalized ratios between readings of the three BNCT neutron beam monitors lay within 0.2%. However, the normalized ratios of readings of the two in-core neutron detectors to one of the BNCT neutron beam monitors show great fluctuations of 5.9% and 17.5%, respectively. PMID:26595774

  18. Design of a Nanometer Beam Size Monitor for ATF2

    CERN Document Server

    Suehara, Taikan; Yamanaka, Takashi; Yoda, Hakutaro; Nakamura, Tomoya; Kamiya, Yoshio; Honda, Yosuke; Kume, Tatsuya; Tauchi, Toshiaki; Sanuki, Tomoyuki; Komamiya, Sachio

    2008-01-01

    We developed an electron beam size monitor for extremely small beam sizes. It uses a laser interference fringe for a scattering target with the electron beam. Our target performance is < 2 nm systematic error for 37 nm beam size and < 10% statistical error in a measurement using 90 electron bunches for 25 - 6000 nm beam size. A precise laser interference fringe control system using an active feedback function is incorporated to the monitor to achieve the target performance. We describe an overall design, implementations, and performance estimations of the monitor.

  19. Proposal for the LHC beam dump upstream diagnostics monitor.

    CERN Document Server

    Variola, A

    2000-01-01

    A diagnostic system is proposed to monitor the beam dilution profile at the entrance of the LHC main beam dump. The monitor exploits two different types of optical photon emission: (a) luminescence on an alumina screen in the case of normal or partial beam dilution; (b) optical transition radiation by a carbon plate in case of a total dilution failure. Based on the analyses, this system is able to resolve with sufficient accuracy the beam location and to resist the beam load under any operating condition. An effective optical set-up of the beam imaging system is also proposed, providing a preliminary design of the diagnostic station.

  20. Beam Shape and Halo Monitor Study

    CERN Document Server

    Lallement, J B; Hori, M; CERN. Geneva. AB Department

    2006-01-01

    The Beam Shape and Halo Monitor, designed by Masaki Hori, is the main diagnostic tool for the 3 MeV test stand scheduled in 2008. This detector will be able to measure the transverse halo generated in the RFQ and the Chopper-line and to detect and measure the longitudinal halo composed of the incompletely chopped bunches. Its principle of functioning is the following: H- ions hit a carbon foil and generate secondary electrons with the same spatial distribution than the incoming beam and a current depending on an emission coefficient given by the carbon foil. These electrons are accelerated towards a phosphor screen by an electric field applied between accelerating grids. Once the electrons reach the phosphor screen, they generate light which is transmitted to a CCD camera via optic fibers [1]. It is expected to give a time resolution of 1-2ns and a spatial resolution of 1mm. The first test of the BSHM done with a Laser has shown a spatial resolution bigger than 1cm and the time resolution bigger than 2ns[2]. ...

  1. NSLS-II RF BEAM POSITION MONITOR

    Energy Technology Data Exchange (ETDEWEB)

    Vetter, K.; Della Penna, A. J.; DeLong, J.; Kosciuk, B.; Mead, J.; Pinayev, I.; Singh, O.; Tian, Y.; Ha, K.; Portmann, G.; Sebek J.

    2011-03-28

    An internal R&D program has been undertaken at BNL to develop a sub-micron RF Beam Position Monitor (BPM) for the NSLS-II 3rd generation light source that is currently under construction. The BPM R&D program started in August 2009. Successful beam tests were conducted 15 months from the start of the program. The NSLS-II RF BPM has been designed to meet all requirements for the NSLS-II Injection system and Storage Ring. Housing of the RF BPM's in +-0.1 C thermally controlled racks provide sub-micron stabilization without active correction. An active pilot-tone has been incorporated to aid long-term (8hr min) stabilization to 200nm RMS. The development of a sub-micron BPM for the NSLS-II has successfully demonstrated performance and stability. Pilot Tone calibration combiner and RF synthesizer has been implemented and algorithm development is underway. The program is currently on schedule to start production development of 60 Injection BPM's starting in the Fall of 2011. The production of {approx}250 Storage Ring BPM's will overlap the Injection schedule.

  2. Achieving beam quality requirements for parity experiments at Jefferson Lab

    International Nuclear Information System (INIS)

    Measurement of asymmetry between alternating opposite electron polarization in electron-nucleon scattering experiments can answer important questions about nucleon structures. Such experiments impose stringent condition on the electron beam quality, and thus the accelerator used for beam creation and delivery. Of particular concern to such ''parity'' experiments is the level of correlation between beam characteristics (orbit, intensity) and electron polarization that can obscure the real asymmetry. This can be introduced at the beam forming stage, created due to scraping, or not damped to desired level due to defective transport. Suppression of such correlation thus demands tight control of the beam line from cathode to target, and requires multi-disciplined approach with collaboration among nuclear physicists and accelerator physicists/engineers. The approach adopted at Jefferson Lab includes reduction of correlation source, improving low energy beam handling, and monitoring and correcting global transport. This paper will discuss methods adopted to meet the performance criteria imposed by parity experiments, and ongoing research aimed at going beyond current performance

  3. Quality assurance and quality control in monitoring programs

    Science.gov (United States)

    Shampine, W.J.

    1993-01-01

    There are three general characteristics of the data to be collected in a monitoring program that should be met in order to maximize the use and value of the data: the data quality should be known the data type and quality should be consistent and comparable, and the data should be available and accessible. Potential problems with each of these characteristics are addressed effectively by quality assurance and quality control. One of the most important aspects of quality assurance in a monitoring program is the development of a quality assurance plan, which should identify clearly the quality of the data needed and describe in detail the planned actions to provide confidence that the program will meet its stated objectives. Quality control data, which allow for the quality and suitability of the environmental data to be evaluated and ascertained, should be collected and utilized as an integral part of the QA effort associated with a monitoring program.

  4. A beam profile monitor using the ionization of residual gas in the beam pipe

    International Nuclear Information System (INIS)

    A beam profile monitor for high energy beams, which has no intercepting parts in the beam pipe, is described. It makes use of the ionization of the residual gas, which is still present in the vacuum chamber of the beam guiding system. The detection of the ionization products is performed with microchannel plates. (orig.)

  5. Iowater Water Quality Monitoring Sites

    Data.gov (United States)

    Iowa State University GIS Support and Research Facility — This coverage contains points representing monitoring locations on streams, lakes and ponds that have been registered by IOWATER monitors. IOWATER, Iowa's volunteer...

  6. Development of capacitive beam position, beam current and Schottky-signal monitors for the Cryogenic Storage Ring (CSR)

    International Nuclear Information System (INIS)

    In this thesis novel techniques based on capacitive pickups for the determination of the beam current, the beam position and the Schottky-signal in storage rings have been developed. Beam current measurements at the heavy ion storage ring TSR with a capacitive pickup have been found in very good agreement with the theory. Using this device the accurate measurement of beam currents at the TSR far below 1 μA is now possible. This method will also be used at the Cryogenic Storage Ring (CSR) at which beam currents in the range of 1 nA-1 μA are expected. For the first time, position measurements with a resonant amplifier system for capacitive pickups have been examined at the TSR for later use of this technique in the CSR. With this method an increased signal-to-noise ratio can be achieved using a parallel inductance. A comparison with measurements using the rest gas beam profile monitor has shown very good agreement even at very low intensities. Experiments with the cryo-capable electronics for the CSR beam position monitors have shown an achievable quality factor of Q=500, resulting in the prospect of precise position measurements at the CSR even at very low beam currents. The CSR Schottky-Pickup will also be equipped with a resonant amplifier system with a comparable quality factor. An estimation of the signal-to-noise ratio suggests a detection limit of a few protons. (orig.)

  7. The N8 channel beam loss monitor system

    International Nuclear Information System (INIS)

    High intensity 70 GeV proton beam loss monitor system architecture in the area of single beam pass is described. The main system components choosing as detectors recording and controlling electronics are grounded on. There are list of the main system monitoring tasks and some experimental results. 12 refs.; 6 figs

  8. Beam-profile monitor using a sodium-vapour

    CERN Multimedia

    1972-01-01

    Beam-profile monitor using a sodium-vapour curtain at 45 degrees to the ISR beam in Ring I (sodium generator is in white cylinder just left of centre). Electrons produced by ionization of the sodium vapour give an image of the beam on a fluorescent screen that is observed by a TV camera (at upper right).

  9. New fast beam profile monitor for electron-positron colliders.

    Science.gov (United States)

    Bogomyagkov, A V; Gurko, V F; Zhuravlev, A N; Zubarev, P V; Kiselev, V A; Meshkov, O I; Muchnoi, N Yu; Selivanov, A N; Smaluk, V V; Khilchenko, A D

    2007-04-01

    A new fast beam profile monitor has been developed at the Budker Institute of Nuclear Physics. This monitor is based on the Hamamatsu multianode photomultiplier with 16 anode strips and provides turn-by-turn measurement of the transverse beam profile. The device is equipped with an internal memory, which has enough capacity to store 131,072 samples of the beam profile. The dynamic range of the beam profile monitor allows us to study turn-by-turn beam dynamics within the bunch charge range from 1 pC up to 10 nC. Using this instrument, we have investigated at the VEPP-4M electron-positron collider a number of beam dynamics effects which cannot be observed by other beam diagnostics tools. PMID:17477653

  10. High resolution beam profile monitors in the SLC

    International Nuclear Information System (INIS)

    In the SLC linac, low emittance beams with typical transverse dimensions less than 0.2 mm must be accelerated without effective emittance growth. In order to monitor this we have installed a high resolution beam profile monitor system which consists of an aluminum target covered with a fine-grained phosphor, a magnifying optical system, a television camera and video signal recording electronics. The image formed when the beam strikes the phosphor screen is viewed on a CRT monitor at the console and selected horizontal and vertical slices of the beam spot intensity are recorded. A 20 MHz transient waveform recorder is used to sample and digitize the raw video signal along the selected slice. The beam width is determined by fitting the background subtracted data to a Gaussian. Beam spots less than 6 x 3 mm can be viewed. Beam spot sizes sigma/sub x,y/ < 80 μm have been measured. 9 refs., 4 figs

  11. Continuous Delivery and Quality Monitoring

    CERN Document Server

    CERN. Geneva

    2016-01-01

    After introducing Continuous Delivery, I will switch the topic and try to answer the question how much should we invest in quality and how to do it efficiently. My observations reveal that software quality is often considered as the slo...

  12. Quality of electron beam irradiated strawberries

    International Nuclear Information System (INIS)

    Fresh 'Tristar' strawberries were treated by electron beam irradiation to determine the effects on postharvest quality attributes and shelf life. The intensity of red color rated by sensory panelists decreased as irradiation dosage increased from 0- to 2 kGy. Hunter 'L' values were higher for fruit treated with 2 kGy than for 0 and 0.5 kGy. Instron firmness values were lower for all irradiated fruit than for control fruit. Panelists rated irradiated fruit less firm than nonirradiated fruit stored 1, 2 and 4 days. An increase in off-flavor was noted among all treatments stored 6 and 8 days. Irradiation suppressed fungi on stored berries. Irradiation doses of 1 and 2 kGy extended shelf life 2 and 4 days, respectively. Electron beam irradiation technology has excellent potential for extension of shelf life of fresh strawberry fruits

  13. A quality audit program for external beam radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Hanson, W.F.; Stovall, M. [Univ. of Texas, Houston, TX (United States)

    1993-12-31

    For more than 25 years, the University of Texas M. D. Anderson Cancer Center has had a quality audit program using mailed dosimeters to verify radiation therapy machine output. Two programs, one compulsory and one voluntary, presently monitor therapy beams at more than 1000 megavoltage-therapy facilities. A successful program requires two major components: a high-precision thermoluminescent dosimeter (TLD) system and dedicated staff that interact closely with the users to resolve discrepancies. The TLD system, the logistics used, and the human interaction of these programs are described. Examples show that the programs can identify major discrepancies, exceeding 5 %, as well as discrepancies as small as 3%.

  14. Development of a Laser Wire Beam Profile Monitor, 1

    CERN Document Server

    Sakamura, Y; Matsuo, H; Sakai, H; Sasao, N; Higashi, Y; Korhonen, T T; Taniguchi, T; Urakawa, J; Sakamura, Yutaka; Hemmi, Yasuo; Matsuo, Hiroaki; Sakai, Hiroshi; Sasao, Noboru; Higashi, Yasuo; Korhonen, Timo; Taniguchi, Takashi; Urakawa, Junji

    1999-01-01

    A conceptual design work and a basic experimental study of a new beam profile monitor have been performed. The monitor will be used to measure emittance of an electron beam in the ATF damping ring at KEK, in which the transverse beam size of about 10 micron is expected. It utilizes a CW laser and an optical cavity, instead of a material wire, to minimize interference with an electron beam. A laser beam with a very thin waist is realized by employing the cavity of nearly concentric mirror configuration while the intensity is amplified by adjusting the cavity length to a Fabry-Perot resonance condition. We built a test cavity to establish a method to measure important parameters such as a laser beam waist and a power enhancement factor. Three independent methods were examined for the measurement of the beam waist. It was found that the cavity realized the beam waist of 20 micron with the power enhancement factor of 50.

  15. Development, Production and Testing of 4500 Beam Loss Monitors

    CERN Document Server

    Holzer, E B; Dehning, B; Ferioli, G; Grishin, V; Jimenez, T M; Koshelev, A; Kramer, Daniel; Larionov, A; Taborelli, M; Seleznev, V; Sleptsov, M; Sytin, A; Wevers, I

    2008-01-01

    Beam-loss monitoring (BLM) [1] is a key element in the LHC machine protection. 4250 nitrogen filled ionization chambers (IC) and 350 secondary emission monitors (SEM) have been manufactured and tested at the Institute for High Energy Physics (IHEP) in Protvino, Russia, following their development at CERN. Signal speed and robustness against aging were the main design criteria. Each monitor is permanently sealed inside a stainless-steel cylinder. The quality of the welding was a critical aspect during production. The SEMs are requested to hold a vacuum of $10^{-7}$ bar. Impurity levels from thermal and radiationinduced desorption should remain in the range of parts per million in the ICs. To avoid radiation aging (up to $2·10^{8}$ Gy in 20 years) production of the chambers followed strict UHV requirements. IHEP designed and built the UHV production stand. Due to the required dynamic range of $10^{8}$, the leakage current of the monitors has to stay below 2 pA. Several tests during and after production were ...

  16. The deformed uncertainty relation and the corresponding beam quality factor

    CERN Document Server

    Li, K; Wang, S M; Li, Kang; Zhao, Dao Mu; Wang, Shao Min

    1996-01-01

    By using the theory of deformed quantum mechanics, we study the deformed light beam theoretically. The deformed beam quality factor M_q^2 is given explicitly under the case of deformed light in coherent state. When the deformation parameter q being a root of unity, the beam quality factor M_q^2 \\leq 1.

  17. High current precision long pulse electron beam position monitor

    CERN Document Server

    Nelson, S D; Fessenden, T J; Holmes, C

    2000-01-01

    Precision high current long pulse electron beam position monitoring has typically experienced problems with high Q sensors, sensors damped to the point of lack of precision, or sensors that interact substantially with any beam halo thus obscuring the desired signal. As part of the effort to develop a multi-axis electron beam transport system using transverse electromagnetic stripline kicker technology, it is necessary to precisely determine the position and extent of long high energy beams for accurate beam position control (6 - 40 MeV, 1 - 4 kA, 2 μs beam pulse, sub millimeter beam position accuracy.) The kicker positioning system utilizes shot-to-shot adjustments for reduction of relatively slow (< 20 MHz) motion of the beam centroid. The electron beams passing through the diagnostic systems have the potential for large halo effects that tend to corrupt position measurements.

  18. The SRI Beam Size Monitor Developed at NSRRC

    CERN Document Server

    Tseng, Tse-Chuan; Ho, H C; Jen Wang, Duan; Kuan, Chien-Kuang; Lin, Chia-Jui; Perng, Shen-Yaw; Wang, Jeremy

    2005-01-01

    A beam size monitor based on the synchrotron radiation interferometer (SRI) was installed in the NSRRC TLS. This monitor consists of a simple diagnostic beamline with a water-cooled beryllium mirror inside and a detecting optical system for both vertical and horizontal beam size measurement. The beam sizes measured are 48 micron and 160 micron respectively and are more close to the theoretical values than the synchrotron image monitor. Comparing with other monitors, at least 1 micron beam size variation is detectable. To minimize the thermal effect, the mirror is located far away from the source point and closed to the detecting optical system. The thermal distortion of the mirror is quite small measured by a portable long trace profiler (LTP) and agrees with the simulating analysis. The detailed monitor system design and testing results are presented in this paper.

  19. Automatic control and monitoring of the MIT fission converter beam

    International Nuclear Information System (INIS)

    An automated control and monitoring system for the new MIT high intensity epithermal neutron irradiation facility has been designed and constructed. The neutron beam is monitored with fission counters located at the periphery of the beam near the patient position. Control of the beam is accomplished with redundant Programmable Logic Controllers (PLCs). These industrial controllers open and close the three shutters of the Fission Converter Beam. The control system uses a series of robust components to assure that the prescribed fluence is delivered. This paper discusses the design and implementation of this system. (author)

  20. Beam Position Monitor Electronics Upgrade for Fermilab Switchyard

    CERN Document Server

    Stabile, P; Fitzgerald, J A; Liu, N; Morris, D K; Prieto, P S; Seraphin, J P

    2015-01-01

    The beam position monitor (BPM) system for Fermilab Switchyard (SY) provides the position, intensity and integrated intensity of the 53.10348 MHz RF bunched resonant extracted beam from the Main Injector over 4 seconds of spill. The total beam intensity varies from 1x10^11 to 1x10^13 protons. The spill is measured by stripline beam postion monitors and resonant circuit. The BPMs have an external resonant circuit tuned to 53.10348 MHz. The corresponding voltage signal out of the BPM has been estimated to be between -110 dBm and -80 dBm.

  1. Model based monitoring of stormwater runoff quality

    DEFF Research Database (Denmark)

    Birch, Heidi; Vezzaro, Luca; Mikkelsen, Peter Steen

    2012-01-01

    Monitoring of micropollutants (MP) in stormwater is essential to evaluate the impacts of stormwater on the receiving aquatic environment. The aim of this study was to investigate how different strategies for monitoring of stormwater quality (combination of model with field sampling) affect the in...

  2. Minimal requirements for quality controls in radiotherapy with external beams

    International Nuclear Information System (INIS)

    Physical dosimetric guidelines have been developed by the Italian National Institute of Health study group on quality assurance in radiotherapy to define protocols for quality controls in external beam radiotherapy. While the document does not determine strict rules or firm recommendations, it suggests minimal requirements for quality controls necessary to guarantee an adequate degree of accuracy in external beam radiotherapy

  3. Optimal beam quality for chest digital radiography

    International Nuclear Information System (INIS)

    To investigate the optimal beam quality for chest computed radiography (CR), we measured the radiographic contrast and evaluated the image quality of chest CR using various X-ray tube voltages. The constant between lung and rib or heart increased on CR image obtained by lowering the tube voltage from 140 to 60 kV, but the degree of increase was less. Scattered radiation was reduced on CR images with a lower tube voltage. The Wiener spectrum of CR images with a low tube voltage showed a low value under identical conditions of amount of light stimulated emission. The quality of chest CR image obtained using a lower tube voltage (80 kV and 100 kV) was evaluated as being superior to those obtained with a higher tube voltage (120 kV and 140 kV). Considering the problem of tube loading and exposure in clinical applications, a tube voltage of 90 to 100 kV (0.1 mm copper filter backed by 0.5 mm aluminum) is recommended for chest CR. (author)

  4. Beam position monitor data acquisition for the Advanced Photon Source

    Energy Technology Data Exchange (ETDEWEB)

    Lenkszus, F.R.; Kahana, E.; Votaw, A.J.; Decker, G.A.; Chung, Y.; Ciarlette, D.J.; Laird, R.J.

    1993-01-01

    This paper describes the Beam Position Monitor (BPM) data acquisition scheme for the Advanced Photon Source (APS) storage ring. The storage ring contains 360 beam position monitors distributed around its 1104-meter circumference. The beam position monitor data acquisition system is capable of making turn-by-turn measurements of all BPMs simultaneously. It is VXI-based with each VXI crate containing the electronics for 9 BPMS. The VXI Local Bus is used to provide sustained data transfer rates of up to 13 mega-transfers per second to a scanner module. The system provides single-bunch tracking, bunch-to-bunch measurements, fast digital-averaged positions, beam position history buffering, and synchronized multi-turn measurements. Data is accessible to the control system VME crates via an MXI bus. Dedicated high-speed ports are provided to supply position data to beam orbit feedback systems.

  5. Beam position monitor data acquisition for the Advanced Photon Source

    Energy Technology Data Exchange (ETDEWEB)

    Lenkszus, F.R.; Kahana, E.; Votaw, A.J.; Decker, G.A.; Chung, Y.; Ciarlette, D.J.; Laird, R.J.

    1993-06-01

    This paper describes the Beam Position Monitor (BPM) data acquisition scheme for the Advanced Photon Source (APS) storage ring. The storage ring contains 360 beam position monitors distributed around its 1104-meter circumference. The beam position monitor data acquisition system is capable of making turn-by-turn measurements of all BPMs simultaneously. It is VXI-based with each VXI crate containing the electronics for 9 BPMS. The VXI Local Bus is used to provide sustained data transfer rates of up to 13 mega-transfers per second to a scanner module. The system provides single-bunch tracking, bunch-to-bunch measurements, fast digital-averaged positions, beam position history buffering, and synchronized multi-turn measurements. Data is accessible to the control system VME crates via an MXI bus. Dedicated high-speed ports are provided to supply position data to beam orbit feedback systems.

  6. Beam position monitor data acquisition for the Advanced Photon Source

    International Nuclear Information System (INIS)

    This paper describes the Beam Position Monitor (BPM) data acquisition scheme for the Advanced Photon Source (APS) storage ring. The storage ring contains 360 beam position monitors distributed around its 1104-meter circumference. The beam position monitor data acquisition system is capable of making turn-by-turn measurements of all BPMs simultaneously. It is VXI-based with each VXI crate containing the electronics for 9 BPMS. The VXI Local Bus is used to provide sustained data transfer rates of up to 13 mega-transfers per second to a scanner module. The system provides single-bunch tracking, bunch-to-bunch measurements, fast digital-averaged positions, beam position history buffering, and synchronized multi-turn measurements. Data is accessible to the control system VME crates via an MXI bus. Dedicated high-speed ports are provided to supply position data to beam orbit feedback systems

  7. Beam Studies Made with the SPS Ionization Profile Monitor

    CERN Document Server

    Ferioli, G; Koopman, J; Roncarolo, F

    2003-01-01

    During the last two years of SPS operation, investigations were pursued on the ability of the SPS ionization profile monitor prototype to fulfill different tasks. It is now established that the instrument can be used for injection matching tuning, by turn to turn recording of the beam size after the injection. Other applications concern beam size measurements on beams ranging from an individual bunch to a nominal SPS batch foreseen for injection into the LHC (288 bunches). By continuously tracking throughout the SPS acceleration cycle from 26 GeV to 450 GeV the evolution of parameters associated to the beam size, it is possible to explain certain beam behaviour. Comparisons are also made at different beam currents and monitor gains with measurements made with the wire scanners. Data are presented and discussed, and the possible implementation of new features is suggested in order to further improve the consistency of the measurements.

  8. Low frequency processing for PSR beam position monitors

    International Nuclear Information System (INIS)

    The beam is injected into the Proton Storage Ring (PSR) as a train of sub-nanosecond pulses at the linac frequency of 201.25 MHz. This frequency component is sensed by 20 pairs of 200 MHz stripline beam position monitors and multiplexed to an autocorrelation position processor. The analog position information is sampled, digitized and stored under the control of timing circuits. Beam position histograms from sets of monitors are displayed in the control room. Measurements show that the amplitude of the 200 MHz component is constant during the fill indicating that the strength of the most recently injected beam does not drift during the fill. This structure begins to disappear 20 to 20 turns after a particular batch of beam has been injected. The low frequency components, however, persist and might be used to measure the position of the accumulated beam. We report calculations and experimental results for some low frequency processing systems

  9. A new luminescence beam profile monitor for intense proton and heavy ion beams

    Energy Technology Data Exchange (ETDEWEB)

    Tsang,T.; Bellavia, S.; Connolly, R.; Gassner, D.; Makdisi, Y.; Russo, T.; Thieberger, P.; Trbojevic, D.; Zelenski, A.

    2008-10-01

    A new luminescence beam profile monitor is realized in the polarized hydrogen gas jet target at the Relativistic Heavy Ion Collider (RHIC) facility. In addition to the spin polarization of the proton beam being routinely measured by the hydrogen gas jet, the luminescence produced by beam-hydrogen excitation leads to a strong Balmer series lines emission. A selected hydrogen Balmer line is spectrally filtered and imaged to produce the transverse RHIC proton beam shape with unprecedented details on the RHIC beam profile. Alternatively, when the passage of the high energy RHIC gold ion beam excited only the residual gas molecules in the beam path, sufficient ion beam induced luminescence is produced and the transverse gold ion beam profile is obtained. The measured transverse beam sizes and the calculated emittances provide an independent confirmation of the RHIC beam characteristics and to verify the emittance conservation along the RHIC accelerator. This optical beam diagnostic technique by making use of the beam induced fluorescence from injected or residual gas offers a truly noninvasive particle beam characterization, and provides a visual observation of proton and heavy ion beams. Combined with a longitudinal bunch measurement system, a 3-dimensional spatial particle beam profile can be reconstructed tomographically.

  10. Optical Beam Timing Monitor Experiments at the Advanced Light Source

    OpenAIRE

    Byrd, John; De Santis, Stefano; Wilcox, Rusell; Yan, Yin

    2008-01-01

    We present the initial results of an experimental study of a beam timing monitor based on an optoelectronic technique. This technique uses the electrical signal from a beam position monitor to modulate the amplitude of a train of laser pulses, converting timing jitter into an amplitude jitter. This modulation is then measured with a photodetector and sampled by a fast ADC. This approach has already demonstrated sub-100 fs resolution and promises even better results. Additionally, we are ...

  11. Simulations of LEIR Injection Line Beam Position Monitors

    CERN Document Server

    Maltseva, Mariya

    2016-01-01

    In this paper sensitivity characteristics of a beam position monitor are described. Characteristics are obtained during the simulations in CST Studio, the results are compared with the calculated values. The results for a low-beta beam and with a wire are compared.

  12. Fast beam condition monitor for CMS: Performance and upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Leonard, Jessica L., E-mail: jessica.lynn.leonard@desy.de [DESY, 15738 Zeuthen (Germany); Bell, Alan [DESY, 15738 Zeuthen (Germany); Burtowy, Piotr [Gdansk University of Technology, 80-233 Gdansk (Poland); Dabrowski, Anne [CERN, 1211 Geneva 23 (Switzerland); Hempel, Maria [DESY, 15738 Zeuthen (Germany); Brandenburg Technical University, 03046 Cottbus (Germany); Henschel, Hans; Lange, Wolfgang [DESY, 15738 Zeuthen (Germany); Lohmann, Wolfgang [DESY, 15738 Zeuthen (Germany); Brandenburg Technical University, 03046 Cottbus (Germany); Odell, Nathaniel [Northwestern University, Evanston, IL, 60208 (United States); Penno, Marek [DESY, 15738 Zeuthen (Germany); Pollack, Brian [Northwestern University, Evanston, IL, 60208 (United States); Przyborowski, Dominik [AGH University of Science and Technology, 30-059 Krakow (Poland); Ryjov, Vladimir [CERN, 1211 Geneva 23 (Switzerland); Stickland, David [Princeton University, Princeton, NJ, 08540 (United States); Walsh, Roberval [DESY, 22607 Hamburg (Germany); Warzycha, Weronika [University of Warsaw, 00-927 Warsaw (Poland); Zagozdzinska, Agnieszka [Warsaw University of Technology, 00-661 Warsaw (Poland)

    2014-11-21

    The CMS beam and radiation monitoring subsystem BCM1F (Fast Beam Condition Monitor) consists of 8 individual diamond sensors situated around the beam pipe within the pixel detector volume, for the purpose of fast bunch-by-bunch monitoring of beam background and collision products. In addition, effort is ongoing to use BCM1F as an online luminosity monitor. BCM1F will be running whenever there is beam in LHC, and its data acquisition is independent from the data acquisition of the CMS detector, hence it delivers luminosity even when CMS is not taking data. A report is given on the performance of BCM1F during LHC run I, including results of the van der Meer scan and on-line luminosity monitoring done in 2012. In order to match the requirements due to higher luminosity and 25 ns bunch spacing, several changes to the system must be implemented during the upcoming shutdown, including upgraded electronics and precise gain monitoring. First results from Run II preparation are shown. - Highlights: • BCM1F uses diamond sensors to measure flux of beam halo and collision products. • The system performed well as a standalone luminometer during LHC Run I. • The high hit rate and radiation post-upgrade require improvements to BCM1F. • Fast electronics have been developed for signal shaping and data readout. • Data from BCM1F will be integrated into online luminosity measurement.

  13. Fast beam condition monitor for CMS: Performance and upgrade

    International Nuclear Information System (INIS)

    The CMS beam and radiation monitoring subsystem BCM1F (Fast Beam Condition Monitor) consists of 8 individual diamond sensors situated around the beam pipe within the pixel detector volume, for the purpose of fast bunch-by-bunch monitoring of beam background and collision products. In addition, effort is ongoing to use BCM1F as an online luminosity monitor. BCM1F will be running whenever there is beam in LHC, and its data acquisition is independent from the data acquisition of the CMS detector, hence it delivers luminosity even when CMS is not taking data. A report is given on the performance of BCM1F during LHC run I, including results of the van der Meer scan and on-line luminosity monitoring done in 2012. In order to match the requirements due to higher luminosity and 25 ns bunch spacing, several changes to the system must be implemented during the upcoming shutdown, including upgraded electronics and precise gain monitoring. First results from Run II preparation are shown. - Highlights: • BCM1F uses diamond sensors to measure flux of beam halo and collision products. • The system performed well as a standalone luminometer during LHC Run I. • The high hit rate and radiation post-upgrade require improvements to BCM1F. • Fast electronics have been developed for signal shaping and data readout. • Data from BCM1F will be integrated into online luminosity measurement

  14. High-speed screen beam-profile-monitor system for high-energy beam-transport line at the HIMAC

    International Nuclear Information System (INIS)

    A screen monitor system was developed for beam profile monitors at the new High-Energy Beam-Transport (HEBT) section out the HIMAC. This monitor consists of the very thin fluorescent screen and the high-speed CCD camera. In addition to perform high-speed and high-resolution, this monitor does not almost destroy the beam. (author)

  15. Higher-order-mode damper as beam-position monitors

    International Nuclear Information System (INIS)

    In the framework of this thesis a beam-position monitor was developed, which can only because of the signals from the HOM dampers of a linear-accelerator structure determine the beam position with high accuracy. For the unique determination of the beam position in the plane a procedure was developed, which uses the amplitudes and the start-phase difference between a dipole mode and a higher monopole mode. In order tocheck the suitability of the present SBLC-HOM damper as beam position monitor three-dimensional numerical field calculations in the frequency and time range and measurements on the damper cell were performed. For the measurements without beam a beam simulator was constructed, which allows computer-driven measurements with variable depositions of the simulated beam with a resolution of 1.23 μm. Because the complete 6 m long, 180-cell accelerator structure was not available for measurements and could also with the available computers not be three-dimensionally simulated simulated, a one-dimensional equivalent-circuit based model of the multi-cell was studied. The equivalent circuits with 879 concentrated components regards the detuning from cell to cell, the cell losses, the damper losses, and the beam excitation in dependence on the deposition. the measurements and simulations let a resolution of the ready beam-position monitor on the 180-cell in the order of magnitude of 1-10 μm and a relative accuracy smaller 6.2% be expected

  16. Beam Position Monitor at the PLS BTL

    CERN Document Server

    Kim, Sung-Chul; Han, Yeung-Jin; Tae Kim, Do; Woo Lee, Wol; Yun Huang Jung

    2005-01-01

    Electron Linac at the Pohnag Accelerator Laboratory (PAL) has been operated continuously as the full energy injector for storage ring. Linac and storage ring energy has been 2.0 GeV since Dec. 1994, and 2.5 GeV since Oct. 2002. In Aug. 2004, thirteen BPMs are newly installed at BTL(Beam Transport Line) for beam trajectory measurement and feedback. These BPMs consist of 100mm strip-line electrodes in 150mm long chamber, and 500MHz log-ratio signal processing circuits. BPM data acquisition system is developed as EPICS IOC using NI S-series data acquisition board and NI LabView 7.1. BTL BPMs will be used for optic correction and beam energy feedback for PLS beam injection. This paper describes on design, test results, installation and data acquisition system of the PLS BTL BPM.

  17. Fast Beam Current Change Monitor for the LHC

    CERN Document Server

    Kral, Jan

    Stringent demands on the LHC safety and protection systems require improved methods of detecting fast beam losses. The Fast Beam Current Transformer (FBCT) is a measurement instrument, providing information about bunch-to-bunch intensity of the accelerated beam. This thesis describes the development of a new protection system based on the FBCT signal measurements. This system, the Fast Beam Current Change Monitor (FBCCM), measures the FBCT signal in a narrow frequency band and computes time derivation of the beam signal magnitude. This derivation is proportional to the beam losses. When the losses exceed a certain level, the FBCCM requests a beam dump in order to protect the LHC. The LHC protection will be ensured by four FBCCMs which will be installed into the LHC in July 2014. Six FBCCMs have been already constructed and their characteristics were measured with satisfactory results. The FBCCMs were tested by a laboratory simulation of the real LHC environment.

  18. Study of an integrated electronic monitor for neutron beams

    International Nuclear Information System (INIS)

    Many neutron beams monitors in 10 keV - 50 keV range are perturbed by gamma radiation impact. This new monitor uses two silicon (junction) diodes operating coincidence detection, combined with an electronic threshold to eliminate gamma background noise. The results and analyses presented here only concern feasibility studies. (D.L.)

  19. IFMIF-LIPAc Beam Diagnostics. Profiling and Loss Monitoring Systems

    International Nuclear Information System (INIS)

    The IFMIF accelerator will accelerate two 125 mA continuous wave (cw) deuteron beams up to 40 MeV and blasts them onto a liquid lithium target to release neutrons. The very high beam power of 10 MW pose unprecedented challenges for the accelerator development. Therefore, it was decided to build a prototype accelerator, the Linear IFMIF Prototype Accelerator (LIPAc), which has the very same beam characteristic, but is limited to 9 MeV only. In the frame of this thesis, diagnostics devices for IFMIF and LIPAc have been developed. The diagnostics devices consist of beam loss monitors and interceptive as well as non-interceptive profile monitors. For the beam loss monitoring system, ionization chambers and diamond detectors have been tested and calibrated for neutron and γ radiation in the energy range expected at LIPAc. During these tests, for the first time, diamond detectors were successfully operated at cryogenic temperatures. For the interceptive profilers, thermal simulations were performed to ensure safe operation. For the non-interceptive profiler, Ionization Profile Monitors (IPMs) were developed. A prototype has been built and tested, and based on the findings, the final IPMs were designed and built. To overcome the space charge of accelerator beam, a software algorithm was written to reconstruct the actual beam profile. (author)

  20. The development of beam current monitors in the APS

    International Nuclear Information System (INIS)

    The Advanced Photon Source (APS) is a third-generation 7-GeV synchrotron radiation source. The precision measurement of beam current is a challenging task in high energy accelerators, such as the APS, with a wide range of beam parameters and complicated noise, radiation, and thermal environments. The beam pulses in the APS injector and storage ring have charge ranging from 50pC to 25nC with pulse durations varying from 30ps to 30ns. A total of nine non- intercepting beam current monitors have been installed in the APS facility (excluding those in the linac) for general current measurement. In addition, several independent current monitors with specially designed redundant interlock electronics are installed for personnel safety and machine protection. This paper documents the design and development of current monitors in the APS,. discusses the commissioning experience in the past year, and presents the results of recent operations

  1. High-resolution phosphor screen beam profile monitor

    International Nuclear Information System (INIS)

    A high-resolution luminescent screen beam profile monitor was developed to allow viewing of both conventional large diameter SLAC e+/e- beams, and also collider rf-bunches having small transverse spatial extent, with one instrument. The principal features of the monitor are described. They include the two-power magnification system offering magnifications of 12 and 78X, respectively; the reticle grid which is optically superimposed on the screen image by a cube beam splitter; selection of a suitable camera; and the Al2O3(Cr) phosphor screen. A simplified version of the monitor for viewing of only micron-sized beams for applications in the collider arcs and final focus regions and achieving a magnification of approx. 40X, coupled with a resolution of approx. 20μm is also presented. 4 refs., 4 figs

  2. Beam profile monitor using alumina screen and CCD camera

    International Nuclear Information System (INIS)

    A pair of beam profile monitors using alumina ceramic screens (Al2O3) and CCD cameras has been developed for diagnosis of a linac beam at the 1.3 GeV electron synchrotron of the Institute for Nuclear Study, the University of Tokyo (INS-ES). Since both the light decay-time of the screen and a shutter speed of the camera are relatively short, about 10 msec or less and 1 msec, respectively, this system is able to measure the beam profile for each pulse of the linac beam operated at a repetition rate of 21.5 Hz. Detailed analysis of the beam profile is made using the stored data on the personal computer. On the other hand, a light spot on the screen is displayed directly on a monitor display. (author)

  3. First Experience with the LHC Beam Loss Monitoring System

    CERN Document Server

    Böhlen, T; Effinger, E; Emery, J; Follin, F; Holzer, E; Jackson, S; Kramer, Daniel; Kruk, G; Le Roux, P; Mariethoz, J; Misiowiec, M; Ponce, L; Roderick, C; Sapinski, M; Zamantzas, C; Stockner, M; Bocian, D; Grishin, V; Ikeda, H; Priebe, A

    2010-01-01

    The LHC beam loss monitoring system (BLM) consists of about 4000 monitors observing losses at all quadrupole magnets and many other likely loss locations. At the first LHC operation in August and September 2008 all monitors were active and used to observe the losses during the initial beam steerings, at collimators, at the LHC dump and during aperture scans. The different acquisition modes and their presentation are shown. Aperture scan loss patterns and a detailed loss pattern leading to a magnet quench are discussed. The observed signals of the BLM system are analyzed in terms of response time, sensitivity and noise performance.

  4. Quality changes of gaussian beams propagating through axicons

    Science.gov (United States)

    Piquero, G.; Mejías, P. M.; Martínez-Herrero, R.

    1994-02-01

    The beam quality parameter of gaussian fields propagating through axicons is investigated. A simple analytical formula is derived for the output quality parameter in terms of the input beam width, refractive index of the axicon material and the angle of the axicon wedge.

  5. LASER-BASED PROFILE MONITOR FOR ELECTRON BEAMS

    International Nuclear Information System (INIS)

    High performance TeV energy electron / positron colliders (LC) are the first machines to require online, non-invasive beam size monitors for micron and sub-micron for beam phase space optimization. Typical beam densities in the LC are well beyond the threshold density for single pulse melting and vaporization of any material, making conventional wire scanners ineffective. Using a finely focused, diffraction limited high power laser, it is possible to devise a sampling profile monitor that, in operation, resembles a wire scanner. Very high resolution laser-based profile monitors have been developed and tested, first at FFTB (SLAC) and later at SLC and ATF. The monitor has broad applicability and we review here the technology, application and status of ongoing research programs

  6. 1 nA Beam position monitor

    International Nuclear Information System (INIS)

    A new BPM system, based on resonant cavities, has been developed for measuring the transverse position of very low-intensity electron beams delivered to Experimental Hall B at the Continuous Electron Beam Accelerator Facility (CEBAF) in Newport News. VA. The system requirements called for measuring down to 1 nA with a 100 m m resolution. The actual system is much better: it can measure down to 100 pA at the 100 m m required resolution. A 100 pA beam yields about 1 electron per bunch. Each 1 nA BPM utilizes three resonant RF cavities to determine the position of the beam: one cavity sensitive to X position, a second cavity sensitive to Y position, and a third cavity which measures intensity. The position cavities operate at room temperature in a dipole type mode at 1497 MHz and contain internal field perturbing rods in an arrangement similar to that of the CEBAF rf Separator cavities. The position cavities are electron beam welded assemblies made of copper plated stainless steel. The RF output signal from each cavity is processed using a down-converter and a DSP based commercial lock-in amplifier operating at 100 kHz. The lock-in amplifiers connect to the EPICS control system via an IEEE 488 bus. System features under development include intensity and position modulation measurement capabilities. This paper provides measured performance results and an updated overview of the installed and operational 1 nA BPM system. copyright 1998 American Institute of Physics

  7. Beam position measurements of Indus-2 using X-Ray beam position monitor

    International Nuclear Information System (INIS)

    A staggered pair metal blade X-ray beam position monitor (XBPM) is designed, fabricated and commissioned on Indus-2 bending magnet front end. Calibration of XBPM is done by scanning the metal blades in the path of synchrotron radiation and by giving controlled electron asymmetric bump. The vertical beam position stability of the source measured during various injections and storages are reported.

  8. A phase-space beam position monitor for synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Samadi, Nazanin, E-mail: nazanin.samadi@usask.ca [University of Saskatchewan, 107 Wiggins Road, Saskatoon, SK (Canada); Bassey, Bassey; Martinson, Mercedes [University of Saskatchewan, 116 Science Place, Saskatoon, SK (Canada); Belev, George; Dallin, Les; Jong, Mark de [Canadian Light Source, 44 Innovation Boulevard, Saskatoon, SK (Canada); Chapman, Dean [University of Saskatchewan, 107 Wiggins Road, Saskatoon, SK (Canada)

    2015-06-25

    A system has been developed to measure the vertical position and angle of the electron beam at a single location from a synchrotron source. The system uses a monochromator tuned to the absorption edge of a contrast material and has a sensitivity comparable with other beam position monitors. The stability of the photon beam position on synchrotron beamlines is critical for most if not all synchrotron radiation experiments. The position of the beam at the experiment or optical element location is set by the position and angle of the electron beam source as it traverses the magnetic field of the bend-magnet or insertion device. Thus an ideal photon beam monitor would be able to simultaneously measure the photon beam’s position and angle, and thus infer the electron beam’s position in phase space. X-ray diffraction is commonly used to prepare monochromatic beams on X-ray beamlines usually in the form of a double-crystal monochromator. Diffraction couples the photon wavelength or energy to the incident angle on the lattice planes within the crystal. The beam from such a monochromator will contain a spread of energies due to the vertical divergence of the photon beam from the source. This range of energies can easily cover the absorption edge of a filter element such as iodine at 33.17 keV. A vertical profile measurement of the photon beam footprint with and without the filter can be used to determine the vertical centroid position and angle of the photon beam. In the measurements described here an imaging detector is used to measure these vertical profiles with an iodine filter that horizontally covers part of the monochromatic beam. The goal was to investigate the use of a combined monochromator, filter and detector as a phase-space beam position monitor. The system was tested for sensitivity to position and angle under a number of synchrotron operating conditions, such as normal operations and special operating modes where the photon beam is intentionally altered

  9. Video-based beam position monitoring at CHESS

    Science.gov (United States)

    Revesz, Peter; Pauling, Alan; Krawczyk, Thomas; Kelly, Kevin J.

    2012-10-01

    CHESS has pioneered the development of X-ray Video Beam Position Monitors (VBPMs). Unlike traditional photoelectron beam position monitors that rely on photoelectrons generated by the fringe edges of the X-ray beam, with VBPMs we collect information from the whole cross-section of the X-ray beam. VBPMs can also give real-time shape/size information. We have developed three types of VBPMs: (1) VBPMs based on helium luminescence from the intense white X-ray beam. In this case the CCD camera is viewing the luminescence from the side. (2) VBPMs based on luminescence of a thin (~50 micron) CVD diamond sheet as the white beam passes through it. The CCD camera is placed outside the beam line vacuum and views the diamond fluorescence through a viewport. (3) Scatter-based VBPMs. In this case the white X-ray beam passes through a thin graphite filter or Be window. The scattered X-rays create an image of the beam's footprint on an X-ray sensitive fluorescent screen using a slit placed outside the beam line vacuum. For all VBPMs we use relatively inexpensive 1.3 Mega-pixel CCD cameras connected via USB to a Windows host for image acquisition and analysis. The VBPM host computers are networked and provide live images of the beam and streams of data about the beam position, profile and intensity to CHESS's signal logging system and to the CHESS operator. The operational use of VBPMs showed great advantage over the traditional BPMs by providing direct visual input for the CHESS operator. The VBPM precision in most cases is on the order of ~0.1 micron. On the down side, the data acquisition frequency (50-1000ms) is inferior to the photoelectron based BPMs. In the future with the use of more expensive fast cameras we will be able create VBPMs working in the few hundreds Hz scale.

  10. AFRRI TRIGA Reactor water quality monitoring program

    International Nuclear Information System (INIS)

    AFRRI has started a water quality monitoring program to provide base line data for early detection of tank leaks. This program revealed problems with growth of algae and bacteria in the pool as a result of contamination with nitrogenous matter. Steps have been taken to reduce the nitrogen levels and to kill and remove algae and bacteria from the reactor pool. (author)

  11. Model based monitoring of stormwater runoff quality

    DEFF Research Database (Denmark)

    Birch, Heidi; Vezzaro, Luca; Mikkelsen, Peter Steen

    2012-01-01

    average and maximum event mean concentrations. Use of this model reduced the uncertainty of predicted annual average concentrations compared to a simple stochastic method based solely on data. The predicted annual average obtained by using passive sampler measurements (one month installation) for......Monitoring of micropollutants (MP) in stormwater is essential to evaluate the impacts of stormwater on the receiving aquatic environment. The aim of this study was to investigate how different strategies for monitoring of stormwater quality (combination of model with field sampling) affect the...... information obtained about MPs discharged from the monitored system. A dynamic stormwater quality model was calibrated using MP data collected by volume-proportional and passive sampling in a storm drainage system in the outskirts of Copenhagen (Denmark) and a 10-year rain series was used to find annual...

  12. The LANSCE Low Momentum Beam Monitor

    CERN Document Server

    Merl, R

    2004-01-01

    A diagnostic has been developed at the Los Alamos Neutron Science Center (LANSCE) for the purpose of identifying low momentum beam tails in the linear accelerator. These tails must be eliminated in order to maintain the transverse and longitudinal beam size. Instead of the currently used phosphor camera system, this instrument consists of a Multi Wire Proportional Chamber (MWPC) front end coupled to an EPICS compliant VME-based electronics package. Low momentum tails are detected with a resolution of 5 mm in the MWPC at a high dispersion point near a bending magnet. While phosphor is typically not sensitive in the nano amp range, the MWPC is sensitive down to about a pico amp. The electronics package processes the signals from each of the MWPC wires to generate an array of beam currents at each of the lower energies. The electronics has an analog front end with a high-speed analog to digital converter for each wire. Data from multiple wires are processed with an embedded digital signal processor and results p...

  13. Data acquisition system for KOMAC beam monitoring using EPICS middleware

    Science.gov (United States)

    Song, Young-Gi

    2015-10-01

    The beam diagnostics instrument used to measure the beam properties is one of the important devices for the 100-MeV proton linear accelerator of the KOrea Multi-purpose Accelerator Complex (KOMAC). A data acquisition system (DAQ) is required to collect the output beam signals conditioned in the analog front-end circuitry of a beam loss monitor (BLM) and a beam position monitor (BPM). The electrical beam signal must be digitized, and the sampling has to be synchronized to a global timing system that produces a pulse signal for the pulsed beam operation. The digitized data must be accessible by the experimental physics and industrial control system (EPICS)-based control system, which manages all accelerator control. An input output controller (IOC), which runs Linux on a central process unit (CPU) module with a peripheral component interconnect (PCI) express-based Analog-to-digital converter (ADC) card, has been adopted to satisfy the requirements. An associated Linux driver and EPICS device support module have also been developed. The IOC meets the requirements, and the development and maintenance of software for the IOC is very efficient. In this paper, the details of the DAQ system for the BLM and the BPM with the introduction of the KOMAC beam-diagnostics devices, along with the performance, are described.

  14. Numerical determination of injector design for high beam quality

    International Nuclear Information System (INIS)

    The performance of a free electron laser strongly depends on the electron beam quality or brightness. The electron beam is transported into the free electron laser after it has been accelerated to the desired energy. Typically the maximum beam brightness produced by an accelerator is constrained by the beam brightness deliverd by the accelerator injector. Thus it is important to design the accelerator injector to yield the required electron beam brightness. The DPC (Darwin Particle Code) computer code has been written to numerically model accelerator injectors. DPC solves for the transport of a beam from emission through acceleration up to the full energy of the injector. The relativistic force equation is solved to determine particle orbits. Field equations are solved for self consistent electric and magnetic fields in the Darwin approximation. DPC has been used to investigate the beam quality consequences of A-K gap, accelerating stress, electrode configuration and axial magnetic field profile

  15. Development of digital beam position monitor based on software radio

    International Nuclear Information System (INIS)

    Digital beam position monitor processor is the key part of a beam position system. A BPM processor based on software radio is much better than traditional processors in terms of the resolution and flexibility. In this paper, we report technical specifications and design considerations of the digital beam position monitor developed at Shanghai Synchrotron Radiation Facility (SSRF). The turn-by-turn electronic resolution of the processor is better than 1.5 μm, when the input power is larger than -30 dBm, and the resolution is better than 2 μm in a test in the SSRF storage ring, with the beam current of over 150 mA. (authors)

  16. Electronics and Calibration system for the CMS Beam Halo Monitor

    CERN Document Server

    Tosi, Nicolò; Fabbri, Franco L; Finkel, Alexey; Orfanelli, Stella; Loos, R; Montanari, Alessandro; Rusack, R; Stickland, David P

    2014-01-01

    In the context of increasing luminosity of LHC, it will be important to accurately measure the Machine Induced Background. A new monitoring system will be installed in the cavern of the Compact Muon Solenoid (CMS) experiment for measuring the beam background at high radius. This detector is composed of synthetic quartz Cherenkov radiators, coupled to fast photomultiplier tubes (PMT). The readout chain of this detector will make use of many components developed for the Phase 1 upgrade to the CMS Hadron Calorimeter electronics, with a dedicated firmware and readout adapted to the beam monitoring requirements. The PMT signal will be digitized by a charge integrating ASIC (QIE10), providing both the signal rise time and the charge integrated over one bunch crossing. The backend electronics will record bunch-by-bunch histograms, which will be published to CMS and the LHC using the newly designed CMS beam instrumentation specific DAQ. A calibration monitoring system has been designed to generate triggered pulses of...

  17. Low and high intensity beam monitoring and tracking

    CERN Document Server

    Lietti, D.; Bolognini, D.; Colombo, J.; Hasan, S.; Mattera, A.; Mozzanica, A.; Prest, M.; Schmitt, B.; Vallazza, E.

    Several detector types have been designed and assembled in order to monitor charged particle beams in a wide range of intensities: silicon microstrip detectors for high precision tracking (spatial resolution better than 5 μm), a scintillating fiber tracker with multianode photomultiplier readout for coarse but fast monitoring, a microstrip silicon detector readout by a counting ASIC to monitor very high intensity beams. These detectors and their readout electronics have been characterized at the BTF (Beam Test Facility) of the INFN National Laboratories of Frascati and used on the H8 line at the CERN SPS as tracking media for the data taking of the H8RD22 collaboration. The paper describes the results obtained in terms of spatial resolution and maximum counting rates.

  18. Beam monitor system for high-energy beam transportation at HIMAC

    CERN Document Server

    Torikoshi, M; Takada, E; Kanai, T; Yamada, S; Ogawa, H; Okumura, K; Narita, K; Ueda, K; Mizobata, M

    1999-01-01

    Heavy-Ion Medical Accelerator in Chiba (HIMAC) provides ion beams for radiotherapy of cancers and for other basic researches. High-energy beam transport lines deliver the beams to three treatment rooms and two experiment rooms with the aid of 41 beam monitor units. Each monitor unit consists of a wire grid as a profile monitor, or a combined unit in which the wire grid and a parallel plate ionization chamber are united for an additional measurement of a beam intensity. They are operated in a mixed gas of 80% Ar and 20% CO sub 2. The gas gain of the wire grid achieves about 8000 at an applied voltage of -2700 V. Dynamic ranges of the wire gird and the parallel plate ionization chamber were measured to be 8x10 sup 5 and 1x10 sup 6 in test using ion beams, respectively. A control system of these monitor units offers easy operation, so that operators are almost free from miss-operations. The monitor units are interlocked with a system which protects patients from the undesired irradiation. Five wire grids are use...

  19. The Beam Conditions Monitor of the LHCb Experiment

    OpenAIRE

    Ilgner, Ch.; Lieng, M. Domke M.; Nedos, M.; Sauerbrey, J.; Schleich, S; Spaan, B.; Warda, K.; Wishahi, J.

    2010-01-01

    The LHCb experiment at the European Organization for Nuclear Research (CERN) is dedicated to precision measurements of CP violation and rare decays of B hadrons. Its most sensitive components are protected by means of a Beam Conditions Monitor (BCM), based on polycrystalline CVD diamond sensors. Its configuration, operation and decision logics to issue or remove the beam permit signal for the Large Hadron Collider (LHC) are described in this paper.

  20. Pin diode calibration - beam overlap monitoring for low energy cooling

    Energy Technology Data Exchange (ETDEWEB)

    Drees, A. [Brookhaven National Lab. (BNL), Upton, NY (United States); Montag, C. [Brookhaven National Lab. (BNL), Upton, NY (United States); Thieberger, P. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2015-09-30

    We were trying to address the question whether or not the Pin Diodes, currently installed approximately 1 meter downstream of the RHIC primary collimators, are suitable to monitor a recombination signal from the future RHIC low energy cooling section. A maximized recombination signal, with the Au+78 ions being lost on the collimator, will indicate optimal Au-electron beam overlap as well as velocity matching of the electron beam in the cooling section.

  1. Charged particle beam current monitoring tutorial

    International Nuclear Information System (INIS)

    A tutorial presentation is made on topics related to the measurement of charged particle beam currents. The fundamental physics of electricity and magnetism pertinent to the problem is reviewed. The physics is presented with a stress on its interpretation from an electrical circuit theory point of view. The operation of devices including video pulse current transformers, direct current transformers, and gigahertz bandwidth wall current style transformers is described. Design examples are given for each of these types of devices. Sensitivity, frequency response, and physical environment are typical parameters which influence the design of these instruments in any particular application. Practical engineering considerations, potential pitfalls, and performance limitations are discussed

  2. Statistical control of the spectral quality index in electron beams

    International Nuclear Information System (INIS)

    Background and purpose: In radiotherapy with electron linear accelerators, it is mandatory to guarantee the stability of beam output spectra. In this work we study the quality control of the magnitude that provides the beam spectral quality, by following statistical techniques usual in industry process. Methods: We establish the differences between the measurement of the reference quality index, R50,ion, which involves usually a costly procedure, and that of the index used for the statistical control, which can be done in an easier way and with a higher frequency. The methodology developed is applied to a Siemens Mevatron KDS electron linear accelerator, specifically for the 6, 12 and 18 MeV modes. The uncertainties of both procedures are evaluated and are correlated. A retrospective analysis of the data registered during more than 13 years is carried out using CUSUM algorithmic and moving range charts. Results: The larger uncertainties in R50,ion come from the measurement device and the observer. The uncertainty in the measurement of the statistical control variable, which is mainly due to the geometry setup, is negligible against its intrinsic variability. The application of CUSUM charts pointed out different out of control situations linked in much cases to assignable causes. In addition, moving range charts showed up situations of anomalous functioning of the LINAC. Conclusions: Algorithmic CUSUM charts permit a nice monitoring of R50,ion. If the variability is not controlled, by using charts such as the moving range ones, the number of false alarms could increase without a change in the mean value of R50,ion.

  3. EXPERIMENTAL RESULTS FROM A MICROWAVE CAVITY BEAM POSITION MONITOR.

    Energy Technology Data Exchange (ETDEWEB)

    BALAKIN,V.; BAZHAN,A.; LUNEV,P.; SOLYAK,N.; VOGEL,V.; ZHOGOLEV,P.; LISITSYN,A.; YAKIMENKO,V.

    1999-03-29

    Future Linear Colliders have hard requirements for the beam transverse position stability in the accelerator. A beam Position Monitor (BPM) with the resolution better than 0.1 micron in the single bunch regime is needed to control the stability of the beam position along the linac. Proposed BPM is based on the measurement of the asymmetrical mode excited by single bunch in the cavity. Four stages of signal processing (space-, time-, frequency- and phase-filtering providing the required signal-to-noise ratio) are used to obtain extremely high resolution. The measurement set-up was designed by BINP and installed at ATF/BNL to test experimentally this concept. The set-up includes three two-coordinates BPM's at the frequency of 13.566 GHz, and reference intensity/phase cavity. BPM's were mounted on support table. The two-coordinates movers allow to move and align BPM's along the straight line, using the signals from the beam. The position of each monitor is controlled by the sensors with the accuracy 0.03 micron. The information from three monitors allows to exclude angle and position jitter of the beam and measure BPM resolution. In the experiments the resolution of about 0.15 micron for 0.25 nC beam intensity was obtained, that is close to the value required.

  4. A Versatile Beam Loss Monitoring System for CLIC

    CERN Document Server

    Kastriotou, Maria; Farabolini, Wilfrid; Holzer, Eva Barbara; Nebot Del Busto, Eduardo; Tecker, Frank; Welsch, Carsten

    2016-01-01

    The design of a potential CLIC beam loss monitoring (BLM) system presents multiple challenges. To successfully cover the 48 km of beamline, ionisation chambers and optical fibre BLMs are under investigation. The former fulfils all CLIC requirements but would need more than 40000 monitors to protect the whole facility. For the latter, the capability of reconstructing the original loss position with a multi-bunch beam pulse and multiple loss locations still needs to be quantified. Two main sources of background for beam loss measurements are identified for CLIC. The two-beam accelerator scheme introduces so-called crosstalk, i.e. detection of losses originating in one beam line by the monitors protecting the other. Moreover, electrons emitted from the inner surface of RF cavities and boosted by the high RF gradients may produce signals in neighbouring BLMs, limiting their ability to detect real beam losses. This contribution presents the results of dedicated experiments performed in the CLIC Test Facility to qu...

  5. Practical application High-Tc SQUID beam current monitor

    International Nuclear Information System (INIS)

    To measure the DC current of heavy-ion beams non-destructively at high resolution, we have developed a high critical temperature (HTc) superconducting quantum interference device (SQUID) beam current monitor for use in the radioactive isotope beam factory (RIBF) at RIKEN. Unlike at other existing facilities, a low vibration, pulse-tube refrigerator cools the HTc fabrications including the SQUID in such a way that the size of the system is reduced and the running costs are lowered. Last year, the magnetic shielding system has been greatly reinforced. The new strong magnetic shielding system can attenuate the external magnetic noise to 10-10. Aiming at its practical use for acceleration operation, the prototype HTc SQUID monitor was disassembled, exchange the improved parts and re-assembled. Beginning this year, we have installed the HTc SQUID monitor in the beam transport line in the RIBF. Here we report the present details of the developed HTc SQUID monitor system and the results of the beam measurement. (author)

  6. Development of Beam Conditions Monitor for the ATLAS experiment

    CERN Document Server

    Dolenc Kittelmann, Irena; Mikuž, M

    2008-01-01

    If there is a failure in an element of the accelerator the resulting beam losses could cause damage to the inner tracking devices of the experiments. This thesis presents the work performed during the development phase of a protection system for the ATLAS experiment at the LHC. The Beam Conditions Monitor (BCM) system is a stand-alone system designed to detect early signs of beam instabilities and trigger a beam abort in case of beam failures. It consists of two detector stations positioned at z=±1.84m from the interaction point. Each station comprises four BCM detector modules installed symmetrically around the beam pipe with sensors located at r=55 mm. This structure will allow distinguishing between anomalous events (beam gas and beam halo interactions, beam instabilities) and normal events due to proton-proton interaction by measuring the time-of-flight as well as the signal pulse amplitude from detector modules on the timescale of nanoseconds. Additionally, the BCM system aims to provide a coarse instan...

  7. A new digital beam position monitor in SSRF

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    The newly developed Digital Beam Position Monitor (DBPM) system is introduced. The DBPM system differs with the conventional beam position monitor system in the use of DSP chips and the digital signal processing technology. It can be programmed on-line to select operation modes through EPICS control panel, and to measure various parameters of the third generation synchrotron radiation facility. This DBPM system can be used in the pre-injector LINAC, the transfer lines, the booster synchrotron and the storage ring. The electronic parameters of the DBPM system itself have been measured also.

  8. Design of the AGS Booster Beam Position Monitor electronics

    International Nuclear Information System (INIS)

    The operational requirements of the AGS Booster Beam Position Monitor system necessitate the use of electronics with wide dynamic range and broad instantaneous bandwidth. Bunch synchronization is provided by a remote timing sequencer coupled to the local ring electronics via digital fiber-optic links. The Sequencer and local ring circuitry work together to provide single turn trajectory or average orbit and intensity information, integrated over 1 to 225 bunches. Test capabilities are built in for the purpose of enhancing BPM system accuracy. This paper describes the design of the Booster Beam Position Monitor electronics, and presents performance details of the front end processing, acquisition and timing circuitry

  9. Medical beam monitor-Pre-clinical evaluation and future applications

    International Nuclear Information System (INIS)

    Future medical ion beam applications for cancer therapy which are based on scanning technology will require advanced beam diagnostics equipment. For a precise analysis of beam parameters we want to resolve time structures in the range of microseconds to nanoseconds. A prototype of an advanced beam monitor was developed by University of Applied Sciences Wiener Neustadt and its research subsidiary Fotec in co-operation with CERN RD42, Ohio State University and the Jozef Stefan Institute in Ljubljana. The detector is based on polycrystalline Chemical Vapor Deposition (pCVD) diamond substrates and is equipped with readout electronics up to 2 GHz analog bandwidth. In this paper we present the design of the pCVD-detector system and results of tests performed in various particle accelerator based facilities. Measurements performed in clinical high energy photon beams agreed within 1.2% with results obtained by standard ionization chambers

  10. Performance of an rf beam monitor on the NBS-Los Alamos racetrack microtron

    International Nuclear Information System (INIS)

    A prototype rf beam-position, current, and phase monitor has been used on the 100-keV injector beamline of the racetrack microtron (RTM) where performance was measured with the chopped and bunched beam. This monitor works with both a pulsed beam and a cw beam. The pulsed beam consists of beam pulses with a FWHM of 40 ns. The rf beam monitor was tested with beam currents from approx. 50 to 600 μA. The rf beam monitor will be described and its performance will be reported. 6 refs., 5 figs

  11. Beam Position and Phase Monitor - Wire Mapping System

    Energy Technology Data Exchange (ETDEWEB)

    Watkins, Heath A [Los Alamos National Laboratory; Shurter, Robert B. [Los Alamos National Laboratory; Gilpatrick, John D. [Los Alamos National Laboratory; Kutac, Vincent G. [Los Alamos National Laboratory; Martinez, Derwin [Los Alamos National Laboratory

    2012-04-10

    The Los Alamos Neutron Science Center (LANSCE) deploys many cylindrical beam position and phase monitors (BPPM) throughout the linac to measure the beam central position, phase and bunched-beam current. Each monitor is calibrated and qualified prior to installation to insure it meets LANSCE requirements. The BPPM wire mapping system is used to map the BPPM electrode offset, sensitivity and higher order coefficients. This system uses a three-axis motion table to position the wire antenna structure within the cavity, simulating the beam excitation of a BPPM at a fundamental frequency of 201.25 MHz. RF signal strength is measured and recorded for the four electrodes as the antenna position is updated. An effort is underway to extend the systems service to the LANSCE facility by replacing obsolete electronic hardware and taking advantage of software enhancements. This paper describes the upgraded wire positioning system's new hardware and software capabilities including its revised antenna structure, motion control interface, RF measurement equipment and Labview software upgrades. The main purpose of the wire mapping system at LANSCE is to characterize the amplitude response versus beam central position of BPPMs before they are installed in the beam line. The wire mapping system is able to simulate a beam using a thin wire and measure the signal response as the wire position is varied within the BPPM aperture.

  12. Influence of mode competition on beam quality of fiber amplifier

    International Nuclear Information System (INIS)

    Theoretical and experimental studies of the influence of the mode competition on the output beam quality of fiber amplifiers are presented. Rate equations and modal decomposition method are used in the theoretical model. In the experiment, the output beam-quality factor of a fiber amplifier, which is based on a Yb-doped double-clad large mode area fiber as a function of the seed beam quality and the pump power of the amplifier, is measured. The experimental results are consistent with the theoretical analysis. (electromagnetism, optics, acoustics, heat transfer, classical mechanics, and fluid dynamics)

  13. Collective monitors for high-current pulse electron beam diagnostics

    International Nuclear Information System (INIS)

    A collector monitor for high-current pulsed electron beams at average power of 100 W and pulse current of 100 A has been developed. The monitor comprises a Faraday cup, profile monitor, sector diaphragm, energy detector. The collector was fixed on a brass radiator transformed into a rod. The rod ensures reliable and electric contact of the collector with the ''earth'' and small RC of this line. Such design permits to stabilize the heat mode of the collector without utilization of external cooling. The monitors have been tested in electron beams at head load up to 100 W during 40 hours. Wear at the expense of evaporation, microexplosions were not observed. Accuracy of current measuring made up 5-10% for absolute and 1-2% for relative measurements

  14. Prototyping of beam position monitor for medium energy beam transport section of RAON heavy ion accelerator

    Science.gov (United States)

    Jang, Hyojae; Jin, Hyunchang; Jang, Ji-Ho; Hong, In-Seok

    2016-02-01

    A heavy ion accelerator, RAON is going to be built by Rare Isotope Science Project in Korea. Its target is to accelerate various stable ions such as uranium, proton, and xenon from electron cyclotron resonance ion source and some rare isotopes from isotope separation on-line. The beam shaping, charge selection, and modulation should be applied to the ions from these ion sources because RAON adopts a superconducting linear accelerator structure for beam acceleration. For such treatment, low energy beam transport, radio frequency quadrupole, and medium energy beam transport (MEBT) will be installed in injector part of RAON accelerator. Recently, development of a prototype of stripline beam position monitor (BPM) to measure the position of ion beams in MEBT section is under way. In this presentation, design of stripline, electromagnetic (EM) simulation results, and RF measurement test results obtained from the prototyped BPM will be described.

  15. PAL-XFEL cavity beam position monitor pick-up design and beam test

    Science.gov (United States)

    Lee, Sojeong; Park, Young Jung; Kim, Changbum; Kim, Seung Hwan; Shin, Dong Cheol; Han, Jang-Hui; Ko, In Soo

    2016-08-01

    As an X-ray Free Electron Laser, PAL-XFEL is about to start beam commissioning. X-band cavity beam position monitor (BPM) is used in the PAL-XFEL undulator beam line. Prototypes of cavity BPM pick-up were designed and fabricated to test the RF characteristics. Also, the beam test of a cavity BPM pick-up was done in the Injector Test Facility (ITF). In the beam test, the raw signal properties of the cavity BPM pick-up were measured at a 200 pC bunch charge. According to the RF test and beam test results, the prototype cavity BPM pick-up design was confirmed to meet the requirements of the PAL-XFEL cavity BPM system.

  16. Prototyping of beam position monitor for medium energy beam transport section of RAON heavy ion accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Hyojae, E-mail: lkcom@ibs.re.kr; Jin, Hyunchang; Jang, Ji-Ho; Hong, In-Seok [Rare Isotope Science Project, Institute for Basic Science, Daejeon (Korea, Republic of)

    2016-02-15

    A heavy ion accelerator, RAON is going to be built by Rare Isotope Science Project in Korea. Its target is to accelerate various stable ions such as uranium, proton, and xenon from electron cyclotron resonance ion source and some rare isotopes from isotope separation on-line. The beam shaping, charge selection, and modulation should be applied to the ions from these ion sources because RAON adopts a superconducting linear accelerator structure for beam acceleration. For such treatment, low energy beam transport, radio frequency quadrupole, and medium energy beam transport (MEBT) will be installed in injector part of RAON accelerator. Recently, development of a prototype of stripline beam position monitor (BPM) to measure the position of ion beams in MEBT section is under way. In this presentation, design of stripline, electromagnetic (EM) simulation results, and RF measurement test results obtained from the prototyped BPM will be described.

  17. Prototyping of beam position monitor for medium energy beam transport section of RAON heavy ion accelerator

    International Nuclear Information System (INIS)

    A heavy ion accelerator, RAON is going to be built by Rare Isotope Science Project in Korea. Its target is to accelerate various stable ions such as uranium, proton, and xenon from electron cyclotron resonance ion source and some rare isotopes from isotope separation on-line. The beam shaping, charge selection, and modulation should be applied to the ions from these ion sources because RAON adopts a superconducting linear accelerator structure for beam acceleration. For such treatment, low energy beam transport, radio frequency quadrupole, and medium energy beam transport (MEBT) will be installed in injector part of RAON accelerator. Recently, development of a prototype of stripline beam position monitor (BPM) to measure the position of ion beams in MEBT section is under way. In this presentation, design of stripline, electromagnetic (EM) simulation results, and RF measurement test results obtained from the prototyped BPM will be described

  18. Reply to comment on 'Proton beam monitor chamber calibration'.

    Science.gov (United States)

    Gomà, Carles; Lorentini, Stefano; Meer, David; Safai, Sairos

    2016-09-01

    This reply shows that the discrepancy of about 3% between Faraday cup dosimetry and reference dosimetry using a cylindrical ionization chamber found in Gomà (2014 Phys. Med. Biol. 59 4961-71) seems to be due to an overestimation of the beam quality correction factors tabulated in IAEA TRS-398 for the cylindrical chamber used, rather than to 'unresolved problems with Faraday cup dosimetry', as suggested by Palmans and Vatnitsky (2016 Phys. Med. Biol. 61 6585-93). Furthermore, this work shows that a good agreement between reference dosimetry and Faraday cup dosimetry is possible, provided accurate beam quality correction factors for proton beams are used. The review on W air values presented by Palmans and Vatnitsky is believed to be inaccurate, as it is based on the imprecise assumption of ionization chamber perturbation correction factors in proton beams being equal to unity. PMID:27535895

  19. Full cycle beam diagnostics with an ionization profile monitor

    International Nuclear Information System (INIS)

    The Alternating Gradient Synchrotron Booster at Brookhaven National Laboratory uses an ionization profile monitor to generate profiles of proton and heavy-ion beams. The profile monitor can acquire hundreds of profiles during an acceleration cycle, and then display and store them for analysis. Profiles appear in real time on an oscilloscope-type display, but other visualizations are available as well, namely mountain range and emittance displays. File storage of profile data is simple, as is the storage of moments and emittances

  20. Application of diamond based beam loss monitors at LHC

    International Nuclear Information System (INIS)

    The Large Hadron Collider (LHC) was conceived in the 1980s and started the operation in 2008. It needed more than 20 years to plan and construct this accelerator and its experiments. Four main experiments are located around the ring, Compact Muon Solenoid (CMS), A Toroidal LHC Apparatus(ATLAS), A Large Ion Collider Experiment (ALICE) and LHC beauty (LHCb). Two beams that traveling in opposite direction in the LHC tunnel, collide in each of the experiments to study the questions: ''What is mass?'', ''What is the universe made of?'' and ''Why is there no antimatter?''. The four experiments take data of the collision products and try to answer the fundamental questions of physics. The two larger detectors, CMS and ATLAS, are looking for the Higgs boson to study the electroweak symmetry breaking. Both detectors were built with contrasting concepts to exclude potential error sources and to rea rm the results. The smaller experiment LHCb studies the matter-antimatter asymmetry with a focus of the beauty quark. Another smaller experiment is ALICE that studies the conditions right after the Big Bang by colliding heavy ions. The navigation of the beams is done by over 10000 magnets and each beam has a stored energy of 362MJ which correspond to the kinetic energy of a train like the TGV travelling of 150 km/h. Only a small percentage of that energy can damage the material in the LHC ring or the magnets. This would mean a repair time of months or years, without taking any data. To avoid such a scenario, it is important to monitor the beam condition and measure the amount of losses of the beam. Such losses can for example happen due to dust particles in the vacuum chambers or due to deviations of the beam parameters. Several systems called beam loss monitors (BLMs) can measure beam losses. This thesis concentrates on two of them, ionization chambers and diamond detectors. Over 3600 ionization chambers are installed in the LHC, especially near each quadrupole and next to

  1. Application of diamond based beam loss monitors at LHC

    Energy Technology Data Exchange (ETDEWEB)

    Hempel, Maria

    2013-04-15

    The Large Hadron Collider (LHC) was conceived in the 1980s and started the operation in 2008. It needed more than 20 years to plan and construct this accelerator and its experiments. Four main experiments are located around the ring, Compact Muon Solenoid (CMS), A Toroidal LHC Apparatus(ATLAS), A Large Ion Collider Experiment (ALICE) and LHC beauty (LHCb). Two beams that traveling in opposite direction in the LHC tunnel, collide in each of the experiments to study the questions: ''What is mass?'', ''What is the universe made of?'' and ''Why is there no antimatter?''. The four experiments take data of the collision products and try to answer the fundamental questions of physics. The two larger detectors, CMS and ATLAS, are looking for the Higgs boson to study the electroweak symmetry breaking. Both detectors were built with contrasting concepts to exclude potential error sources and to rea rm the results. The smaller experiment LHCb studies the matter-antimatter asymmetry with a focus of the beauty quark. Another smaller experiment is ALICE that studies the conditions right after the Big Bang by colliding heavy ions. The navigation of the beams is done by over 10000 magnets and each beam has a stored energy of 362MJ which correspond to the kinetic energy of a train like the TGV travelling of 150 km/h. Only a small percentage of that energy can damage the material in the LHC ring or the magnets. This would mean a repair time of months or years, without taking any data. To avoid such a scenario, it is important to monitor the beam condition and measure the amount of losses of the beam. Such losses can for example happen due to dust particles in the vacuum chambers or due to deviations of the beam parameters. Several systems called beam loss monitors (BLMs) can measure beam losses. This thesis concentrates on two of them, ionization chambers and diamond detectors. Over 3600 ionization chambers are installed in

  2. Monitoring water quality by remote sensing

    Science.gov (United States)

    Brown, R. L. (Principal Investigator)

    1977-01-01

    The author has identified the following significant results. A limited study was conducted to determine the applicability of remote sensing for evaluating water quality conditions in the San Francisco Bay and delta. Considerable supporting data were available for the study area from other than overflight sources, but short-term temporal and spatial variability precluded their use. The study results were not sufficient to shed much light on the subject, but it did appear that, with the present state of the art in image analysis and the large amount of ground truth needed, remote sensing has only limited application in monitoring water quality.

  3. Beam Tests of a Prototype Stripline Beam Position Monitoring System for the Drive Beam of the CLIC Two-beam Module at CTF3

    CERN Document Server

    Benot-Morell, Alfonso; Nappa, Jean-Marc; Vilalte, Sebastien; Wendt, Manfred

    2016-01-01

    In collaboration with LAPP and IFIC, two units of a prototype stripline Beam Position Monitor (BPM) for the CLIC Drive Beam (DB), and its associated readout electronics have been successfully installed and tested in the Two-Beam-Module (TBM) at the CLIC Test Facility 3 (CTF3) at CERN. This paper gives a short overview of the BPM system and presents the performance measured under different Drive Beam configurations.

  4. Gaussian Content as a Laser Beam Quality Parameter

    OpenAIRE

    Ruschin, Shlomo; Yaakobi, Elad; Shekel, Eyal

    2011-01-01

    We propose the Gaussian Content as an optional quality parameter for the characterization of laser beams. It is defined as the overlap integral of a given field with an optimally defined Gaussian. The definition is specially suited for applications where coherence properties are targeted. Mathematical definitions and basic calculation procedures are given along with results for basic beam profiles. The coherent combination of an array of laser beams and the optimal coupling between a diode la...

  5. Basic Developments of Quality Characteristics Monitoring

    OpenAIRE

    Shahryar Sorooshian

    2013-01-01

    Process control tools are a widely used approach in many operations and production processes. Process control chart ranks as one of the most important theories used in these disciplines. This paper reviewed the bias of quality characteristics monitoring. Specifically, this study tries to provide a comprehensive understanding of theories of process control. The text starts with a theoretical review of statistical process control theories and follows by a technical introduction to developed too...

  6. Cherenkov Fibers for Beam Loss Monitoring at the CLIC Two Beam Module

    CERN Document Server

    van Hoorne, Jacobus Willem; Holzer, E B

    The Compact Linear Collider (CLIC) study is a feasibility study aiming at a nominal center of mass energy of 3TeV and is based on normal conducting travelling-wave accelerating structures, operating at very high field gradients of 100 MV/m. Such high fields require high peak power and hence a novel power source, the CLIC two beam system, has been developed, in which a high intensity, low energy drive beam (DB) supplies energy to a high energy, low intensity main beam (MB). At the Two Beam Modules (TBM), which compose the 2x21km long CLIC main linac, a protection against beam losses resulting from badly controlled beams is necessary and particularly challenging, since the beam power of both main beam (14 MW) and drive beam (70 MW) is impressive. To avoid operational downtimes and severe damages to machine components, a general Machine Protection System (MPS) scheme has been developed. The Beam Loss Monitoring (BLM) system is a key element of the CLIC machine protection system. Its main role will be to detect p...

  7. Quality assurance for radiochemical measurements and monitoring

    International Nuclear Information System (INIS)

    Since 1954, the Environmental Protection Agency (EPA) and its predecessor, the US Public Health Service, has operated an environmental radiation monitoring program in a 100,000 square mile region surrounding the Nevada Test Site and at former nuclear test sites in Alaska, Colorado, New Mexico, and Mississippi. This program is designed to measure levels and trends of radioactivity in the environment surrounding test areas, determine compliance with existing regulations, and protect the health and well-being of the public in the event of any accidental release of radioactive contaminants. Levels of radiation and radioactivity are assessed by sampling water, milk, and air; deploying thermoluminescent dosimeters (TLDs); measurements using pressurized ion chambers (PICs); and biological monitoring of both animals and humans. To ensure that all decisions and actions are supported by environmental measurement of known quality, the EPA requires a locally implemented quality assurance program. Elements of this program include: a quality assurance plan for each of the sampling networks; standard operating procedures for field monitors and analysts; and a routine review of all data by network auditors. To further test the validity of data, the radioanalytical laboratory regularly participates in EPA, Department of Energy (DOE), and World Health Organization (WHO) intercomparison studies

  8. Water quality monitoring using remote sensing technique

    Science.gov (United States)

    Adsavakulchai, Suwannee; Panichayapichet, Paweena

    2003-03-01

    There has been a rapid growth of shrimp farm around Kung Krabaen Bay in the past decade. This has caused enormous rise in generation of domestic and industrial wastes. Most of these wastes are disposed in the Kung Krabaen Bay. There is a serious need to retain this glory by better water quality management of this river. Conventional methods of monitoring of water quality have limitations in collecting information about water quality parameters for a large region in detailed manner due to high cost and time. Satellite based technologies have offered an alternate approach for many environmental monitoring needs. In this study, the high-resolution satellite data (LANDSAT TM) was utilized to develop mathematical models for monitoring of chlorophyll-a. Comparison between empirical relationship of spectral reflectance with chl-a and band ratio between the near infrared (NIR) and red was suggested to detect chlorophyll in water. This concept has been successfully employed for marine zones and big lakes but not for narrow rivers due to constraints of spatial resolution of satellite data. This information will be very useful in locating point and non-point sources of pollution and will help in designing and implementing controlling structures.

  9. Long bunch trains measured using a prototype cavity beam position monitor for the Compact Linear Collider

    Science.gov (United States)

    Cullinan, F. J.; Boogert, S. T.; Farabolini, W.; Lefevre, T.; Lunin, A.; Lyapin, A.; Søby, L.; Towler, J.; Wendt, M.

    2015-11-01

    The Compact Linear Collider (CLIC) requires beam position monitors (BPMs) with 50 nm spatial resolution for alignment of the beam line elements in the main linac and beam delivery system. Furthermore, the BPMs must be able to make multiple independent measurements within a single 156 ns long bunch train. A prototype cavity BPM for CLIC has been manufactured and tested on the probe beam line at the 3rd CLIC Test Facility (CTF3) at CERN. The transverse beam position is determined from the electromagnetic resonant modes excited by the beam in the two cavities of the pickup, the position cavity and the reference cavity. The mode that is measured in each cavity resonates at 15 GHz and has a loaded quality factor that is below 200. Analytical expressions for the amplitude, phase and total energy of signals from long trains of bunches have been derived and the main conclusions are discussed. The results of the beam tests are presented. The variable gain of the receiver electronics has been characterized using beam excited signals and the form of the signals for different beam pulse lengths with the 2 /3 ns bunch spacing has been observed. The sensitivity of the reference cavity signal to charge and the horizontal position signal to beam offset have been measured and are compared with theoretical predictions based on laboratory measurements of the BPM pickup and the form of the resonant cavity modes as determined by numerical simulation. Finally, the BPM was calibrated so that the beam position jitter at the BPM location could be measured. It is expected that the beam jitter scales linearly with the beam size and so the results are compared to predicted values for the latter.

  10. Multifunctional monitor of beam parameters for a cyclotron

    International Nuclear Information System (INIS)

    The ionization monitor is described designed for on-line monitoring of beam intensity and position in a cyclotron transport channel, and also of beam current pulse form related to a modulation of accelerating voltage and beam energy. The monitor comprises the extracting system in a form of flat capacitor formed by the reflecting electrode and forming grid. To eliminate the effect of slow ionic component the reflecting electrode is provided with an antidynatron grid. The electron component istransmitted to the electron multiplier with a gain factor up to 108 assembled on two microchannel electron plates. Thethreshold monitor sensitivity at a pressure of 10sup(-5)Tor constitutes 10sup(-11) - 10sup(-12) A. Introduction of a special stroboscopic electrode between the electron multiplier and transducer allows one to record timing beam parameters, in particular, microbunches duration and phase position. The complex of electronic equipment for visualization and digital processing of measuring results is constructed on the basis of the CAMAC units and TV set. up

  11. Development of fiber beam loss monitor based on Cerenkov principle

    International Nuclear Information System (INIS)

    Background: A new type of beam loss monitor (BLM) system is needed in the synchrotron radiation light source or FEL facility to monitor the real-time beam loss inside the small-gap insertion devices. Purpose: A BLM system was developed with optical fiber as the probe to meet the requirements of SSRF. Methods: The whole system consists of a 30-m long step-index fiber, photomultiplier tubes (PMT), a 10-bit 8-GS/s high-speed waveform digitizer and a PXI input-output controller. The software was developed under the Linux system based on Experimental Physics and Industrial Control System (EPICS). A new measurement and corresponding calculation method were designed to make the system work well with the multi-bunch operation mode in the storage ring of SSRF. Results: The BLM system worked well at SSRF. And the results of beam experiments showed that the system could detect beam loss properly even at the 1-mA low current case. Conclusions: This system could be used in the detection of beam loss dose and position. In the experiments the counts of light pulses can be used as a rough estimation of beam loss dose. The noise floor is about 3.56% of the total count in the 220-mA top-up user operation mode. (authors)

  12. Progress on the development of APS beam position monitoring system

    International Nuclear Information System (INIS)

    This paper describes the development status of the beam position monitoring system for the Advanced Photon Source (APS), a third-generation light source now under construction at Argonne National Laboratory. The accelerator complex will consist of an electron linac, a positron linac, a positron accumulator ring (PAR), an injector synchrotron and a storage ring. For beam position measurement, striplines will be used on the linacs, while button-type pickups will be used on the injector synchrotron and the storage ring. A test stand with a prototype injector synchrotron beam position monitor (BPM) unit has been built, and we present the results of position calibration measurements using a wire. Comparison of the results with theoretical calculations will be presented. The current effort on similar storage ring BPM system measurements will also be discussed. 4 refs., 5 figs., 2 tabs

  13. Characterization of Nonparaxial Truncated Cosine-Gaussian Beams and the Beam Quality in the Far Field

    Institute of Scientific and Technical Information of China (English)

    KANG Xiao-Ping; L(U) Bai-Da

    2006-01-01

    @@ The analytical expression characterizing the propagation of nonparaxial truncated cosine-Gaussian (CoG) beams in free space is derived, and some special cases are discussed. The extended power in the bucket (PIB) is proposed to characterize the beam quality of nonparaxial truncated beams in the far field. It is shown that the extended PIB is applicable to nonparaxial truncated beams, and the PIB of nonparaxial truncated CoG beams depends on the decentred parameter, waist-width-to-wavelength ratio, truncation parameter, and bucket size chosen.

  14. First Beam Measurements with the LHC Synchrotron Light Monitors

    Energy Technology Data Exchange (ETDEWEB)

    Lefevre, Thibaut; /CERN; Bravin, Enrico; /CERN; Burtin, Gerard; /CERN; Guerrero, Ana; /CERN; Jeff, Adam; /CERN; Rabiller, Aurelie; /CERN; Roncarolo, Federico; /CERN; Fisher, Alan; /SLAC

    2012-07-13

    The continuous monitoring of the transverse sizes of the beams in the Large Hadron Collider (LHC) relies on the use of synchrotron radiation and intensified video cameras. Depending on the beam energy, different synchrotron light sources must be used. A dedicated superconducting undulator has been built for low beam energies (450 GeV to 1.5 TeV), while edge and centre radiation from a beam-separation dipole magnet are used respectively for intermediate and high energies (up to 7 TeV). The emitted visible photons are collected using a retractable mirror, which sends the light into an optical system adapted for acquisition using intensified CCD cameras. This paper presents the design of the imaging system, and compares the expected light intensity with measurements and the calculated spatial resolution with a cross calibration performed with the wire scanners. Upgrades and future plans are also discussed.

  15. A button - type beam position monitor design for TARLA facility

    Science.gov (United States)

    Gündoǧan, M. Tural; Kaya, ć.; Yavaş, Ö.

    2016-03-01

    Turkish Accelerator and Radiation Laboratory in Ankara (TARLA) facility is proposed as an IR FEL and Bremsstrahlung facility as the first facility of Turkish Accelerator Center (TAC). TARLA is essentially proposed to generate oscillator mode FEL in 3-250 microns wavelengths range, will consist of normal conducting injector system with 250 keV beam energy, two superconducting RF accelerating modules in order to accelerate the beam 15-40 MeV. The TARLA facility is expected to provide two modes, Continuous wave (CW) and pulsed mode. Longitudinal electron bunch length will be changed between 1 and 10 ps. The bunch charge will be limited by 77pC. The design of the Button-type Beam Position Monitor for TARLA IR FEL is studied to operate in 1.3 GHz. Mechanical antenna design and simulations are completed considering electron beam parameters of TARLA. Ansoft HFSS and CST Particle Studio is used to compare with results of simulations.

  16. Initial Survey Instructions for Spring Water Monitoring : Quality

    Data.gov (United States)

    US Fish and Wildlife Service, Department of the Interior — Initial survey instructions for 1.04 spring water monitoring (quality) and 1.06 management unit water monitoring (quality) at Fish Springs National Wildlife Refuge....

  17. Air Quality System (AQS) Monitoring Network, EPA OAR OAQPS

    Data.gov (United States)

    U.S. Environmental Protection Agency — This GIS dataset contains points which depict air quality monitors within EPA's Air Quality System (AQS) monitoring network. This dataset is updated weekly to...

  18. Beam position monitors for the high brightness lattice

    International Nuclear Information System (INIS)

    Engineering developments associated with the high brightness lattice and the projected change in machine operating parameters will inherently affect the diagnostics systems and devices installed at present in the storage ring. This is particularly true of the beam position monitoring (BPI) system. The new sixteen unit cell lattice with its higher betatron tune values and the limited space available in the redesigned machine straights for fitting standard BPI vessels forces a fundamental re-evaluation of the beam position monitor system. The design aims for the new system are based on accepting the space limitations imposed while still providing the monitor points required to give good radial and vertical closed orbit plots. The locations of BPI's in the redesigned machine straights is illustrated. A description of the new BPI assemblies and their calibration is given. The BPI's use capacitance button type pick-ups; their response is described. (U.K.)

  19. LHC Beam Loss Monitoring System Verification Applications

    CERN Document Server

    Dehning, B; Zamantzas, C; Jackson, S

    2011-01-01

    The LHC Beam Loss Mon­i­tor­ing (BLM) sys­tem is one of the most com­plex in­stru­men­ta­tion sys­tems de­ployed in the LHC. In ad­di­tion to protecting the col­lid­er, the sys­tem also needs to pro­vide a means of di­ag­nos­ing ma­chine faults and de­liv­er a feed­back of loss­es to the control room as well as to sev­er­al sys­tems for their setup and analysis. It has to trans­mit and pro­cess sig­nals from al­most 4’000 mon­i­tors, and has near­ly 3 mil­lion con­fig­urable pa­ram­e­ters. The system was de­signed with re­li­a­bil­i­ty and avail­abil­i­ty in mind. The spec­i­fied op­er­a­tion and the fail-safe­ty stan­dards must be guar­an­teed for the sys­tem to per­form its func­tion in pre­vent­ing su­per­con­duc­tive mag­net de­struc­tion caused by par­ti­cle flux. Main­tain­ing the ex­pect­ed re­li­a­bil­i­ty re­quires ex­ten­sive test­ing and ver­i­fi­ca­tion. In this paper we re­port our most re­cent ad­di­t...

  20. Radiation Tolerance of Cryogenic Beam Loss Monitor Detectors

    CERN Document Server

    Kurfuerst, C; Bartosik, M; Dehning, B; Eisel, T; Sapinski, M; Eremin, V; Verbitskaya, E; Fabjan, C; Griesmayer, E

    2013-01-01

    At the triplet magnets, close to the interaction regions of the LHC, the current Beam Loss Monitoring system is sensitive to the particle showers resulting from the collision of the two beams. For the future, with beams of higher energy and intensity resulting in higher luminosity, distinguishing between these interaction products and possible quench-provoking beam losses from the primary proton beams will be challenging. Investigations are therefore underway to optimise the system by locating the beam loss detectors as close as possible to the superconducting coils of the triplet magnets. This means putting detectors inside the cold mass in superfluid helium at 1.9 K. Previous tests have shown that solid state diamond and silicon detectors as well as liquid helium ionisation chambers are promising candidates. This paper will address the final open question of their radiation resistance for 20 years of nominal LHC operation, by reporting on the results from high irradiation beam tests carried out at CERN in a...

  1. Beam Profile Monitor Tests at the SLAC FFTB^1

    Science.gov (United States)

    Norem, J.; Dawson, J.; Haberichter, W.; Reed, L.; Yang, X.-F.; Spencer, J.; Saleski, M.

    1996-05-01

    The next generation linear colliders require beam sizes as small as 5 nm for efficient collisions between electron and positron beams. The difficulty of producing and maintaining such beams in stable collision means that bunch-to-bunch measurements need to be made quickly and precisely. We are developing a new technique using non-imaging gamma optics having good time resolution and sensitivity to correlations when the expected resolution is a few nm. Apparatus has been set up and made operational in the Final Focus Test Beam at SLAC and we have begun to tune and test components. We will describe this setup and our initial measurements together with Monte Carlo simulations based on using foils and wires (bremsstrahlung) and laser backscattering (Compton) as gamma sources to measure the beam size at IP1 of experiment E144. For the NLC we could also use beamsstrahlung generated by the strong beam-beam interaction at the IP to provide a comparable nonintercepting monitor. \\overline ^1Funded by the US Department of Energy under contracts W-31-109-ENG-38 and DE-AC03-76SF00515.

  2. Status of the Stripline Beam Position Monitor developement for the CLIC Drive Beam

    CERN Document Server

    Benot-Morell, A; Wendt, M; Faus-Golfe, A; Nappa, J M; Vilalte, S; Smith, S

    2013-01-01

    In collaboration with SLAC, LAPP and IFIC, a first prototype of a stripline Beam Position Monitor (BPM) for the CLIC Drive Beam and its associated readout electronics has been successfully tested in the CLIC Test Facility linac (CTF3) at CERN. In addition, a modified prototype with downstream terminated striplines is under development to improve the suppression of unwanted RF signal interference. This paper presents the results of the beam tests, and the most relevant aspects for the modified stripline BPM design and its expected improvements.

  3. Measuring Beam Quality of Hollow Core Photonic Crystal Fibers

    DEFF Research Database (Denmark)

    Shephard, J.D.; Roberts, John; Jones, J.D.C.;

    2006-01-01

    In this paper, the authors measure the quality of the delivered beam from hollow core photonic crystal fibers (HC-PCFs). The$M^2$parameter is determined, and the near- to far-field transition is examined. The influence on these properties due to the presence of a core surround mode is evaluated....... The applicability of the International Standards Organization 11146 : 1999 standard for$M^2$measurement of the beam quality of HC-PCFs is discussed. Because they are dependent on the measurement parameters, such as choice of aperturing scheme and the axis of measurement,$M^2$values could vary from 1.......32 to 3.17 for the same output beam. This highlights the need for careful consideration when measuring and describing the beam quality delivered by these novel photonic fibers....

  4. Beam Loss Position Monitor Using Cerenkov Radiation in Optical Fibers

    CERN Document Server

    Körfer, M

    2005-01-01

    Single pass Free Electron Lasers SASE-FELs are developed for high brightness and short wavelength applications. The VUV-FEL at DESY will reach an average beam power of about 72 kW. To avoid particle losses in the radiation sensitive undulators a collimator system is installed. However, the proper operation of the collimator system needs to be measured with a beam loss monitor. Conventional radiation sensor systems are not suited for the VUV-FEL undulators, because the free space in the undulator gap is less than 1 mm. A Beam Loss Position Monitor (BLPM) based on Cerenkov light in optical fibers allows the monitoring of losses inside the undulator. Electrons with energies above 175 keV generate Cerenkov light during their penetration of the optical fiber. The fast response of the Cerenkov signal is detected with photomultipliers at the end of the irradiated fibers. The beam loss position along the section of interest can be determinate by exploiting the system trigger (bunch clock) of the accelerator system. T...

  5. Beam Loss Monitoring for Run 2 of the LHC

    CERN Document Server

    Kalliokoski, Matti; Dehning, Bernd; Domingues Sousa, Fernando; Effinger, Ewald; Emery, Jonathan; Grishin, Viatcheslav; Holzer, Eva Barbara; Jackson, Stephen; Kolad, Blazej; Nebot Del Busto, Eduardo; Picha, Ondrej; Roderick, Chris; Sapinski, Mariusz; Sobieszek, Marcin; Zamantzas, Christos

    2015-01-01

    The Beam Loss Monitoring (BLM) system of the LHC consists of over 3600 ionization chambers. The main task of the system is to prevent the superconducting magnets from quenching and protect the machine components from damage, as a result of critical beam losses. The BLM system therefore requests a beam abort when the measured dose in the chambers exceeds a threshold value. During Long Shutdown 1 (LS1) a series of modifications were made to the system. Based on the experience from Run 1 and from improved simulation models, all the threshold settings were revised, and modified where required. This was done to improve the machine safety at 7 TeV, and to reduce beam abort requests when neither a magnet quench or damage to machine components is expected. In addition to the updates of the threshold values, about 800 monitors were relocated. This improves the response to unforeseen beam losses in the millisecond time scale due to micron size dust particles present in the vacuum chamber. This contribution will discuss...

  6. High power laser beam delivery monitoring for laser safety

    Science.gov (United States)

    Corder, D. A.; Evans, D. R.; Tyrer, J. R.; Freeland, C. M.; Myler, J. K.

    1997-07-01

    The output of high power lasers used for material processing presents extreme radiation hazards. In normal operation this hazard is removed by the use of local shielding to prevent accidental exposure and system design to ensure efficient coupling of radiation into the workpiece. Faults in laser beam delivery or utilization can give rise to hazardous levels of laser radiation. A passive hazard control strategy requires that the laser system be enclosed such that the full laser power cannot burn through the housing under fault conditions. Usually this approach is too restrictive. Instead, active control strategies can be used in which a fault condition is detected and the laser cut off. This reduces the requirements for protective housing. In this work a distinction is drawn between reactive and proactive strategies. Reactive strategies rely on detecting the effects of an errant laser beam, whereas proactive strategies can anticipate as well as detect fault conditions. This can avoid the need for a hazardous situation to exist. A proactive strategy in which the laser beam is sampled at the final turning mirror is described in this work. Two control systems have been demonstrated; the first checks that beam power is within preset limits, the second monitors incoming beam power and position, and the radiation reflected back from the cutting head. In addition to their safety functions the accurate monitoring of power provides an additional benefit to the laser user.

  7. Integrating and automating the software environment for the Beam and Radiation Monitoring for CMS

    CERN Document Server

    Filyushkina, Olga; Juslin, J

    2010-01-01

    The real-time online visualization framework used by the Beam and Radiation Monitoring group at the Compact Muon Solenoid at Large Hadron Collider, CERN. The purpose of the visualization framework is to provide real-time diagnostic of beam conditions, which defines the set of the requirements to be met by the framework. Those requirements include data quality assurance, vital safety issues, low latency, data caching, etc. The real-time visualization framework is written in the Java programming language and based on JDataViewer--a plotting package developed at CERN. At the current time the framework is run by the Beam and Radiation Monitoring, Pixel, Tracker groups, Run Field Manager and others. It contributed to real-time data analysis during 2009-2010 runs as a stable monitoring tool. The displays reflect the beam conditions in a real-time with the low latency level, thus it is the first place at the CMS detector where the beam collisions are observed.

  8. Electronics and Calibration system for the CMS Beam Halo Monitor

    CERN Document Server

    Tosi, Nicolo

    2014-01-01

    In the context of increasing luminosity of LHC, it will be important to accurately measure the Machine Induced Background. A new monitoring system will be installed in the CMS cavern for measuring the beam background at high radius. This detector is composed of synthetic quartz Cherenkov radiators, coupled to fast photomultiplier tubes (PMT). The readout chain of this detector will make use of many components developed for the Phase 1 upgrade to the CMS Hadron Calorimeter electronics, with a dedicated firmware and readout adapted to the beam monitoring requirements. The PMT signal will be digitized by a charge integrating ASIC (QIE10), providing both the signal rise time and the charge integrated over one bunch crossing.The backend electronics will record bunch-by-bunch histograms, which will be published to CMS and the LHC using the newly designed CMS beam instrumentation specific DAQ. A calibration monitoring system has been designed to generate triggered pulses of light to monitor the efficiency of the sys...

  9. Beam position dependence of a wall-current monitor

    International Nuclear Information System (INIS)

    It was pointed out recently that there exists an appreciable beam position dependence in the wall-current monitor widely used in electron accelerators. Detailed study of this dependence is performed on a test bench varying the pulse width and the frequency of the input signal simulating the beam. The results of experiments show that when the pulse width becomes shorter more appreciable becomes the dependence, and it approaches to that of calculated from the method of images. A unified analysis is under way. (author)

  10. Air Qualitymonitoring and modelling

    Directory of Open Access Journals (Sweden)

    Marius DEACONU

    2012-12-01

    Full Text Available Air pollution is a major concern for all nations, regardless of their development. The rapid growth of the industrial sector and urban development have lead to significant quantities of substances and toxic materials, mostly discharged into the atmosphere and having adverse effects both on human health and environment in general. Human society has to recognize that environment has only a limited capacity to process all of its waste without major changes. Each of us is a pollutant but also a victim of pollution. If monitoring of air pollutants is particularly important for assessing the air quality at any moment, by modelling the monitoring data spectacular results are obtained both through the factor analysis and identification of potential pollution mitigation measures. Latest equipment and techniques come and support these problems giving medium and long term solutions.

  11. Monitoring of whey quality with NIR spectroscopy

    DEFF Research Database (Denmark)

    Kucheryavskiy, Sergey; Lomborg, Carina

    2015-01-01

    The possibility of using near-infrared (NIR) spectroscopy for monitoring of liquid whey quality parameters during protein production process has been tested. The parameters included total solids, lactose, protein and fat content. The samples for the experiment were taken from real industrial...... processes and had a large variability for most of the parameters. Partial Least Squares (PLS) regression was used to make the prediction models based on NIR spectra taken at 30 and 40 °C. Using proper wavelength range allowed to get models for prediction of fat, protein and amount of total solids with very...

  12. CMS data quality monitoring web service

    International Nuclear Information System (INIS)

    A central component of the data quality monitoring system of the CMS experiment at the Large Hadron Collider is a web site for browsing data quality histograms. The production servers in data taking provide access to several hundred thousand histograms per run, both live in online as well as for up to several terabytes of archived histograms for the online data taking, Tier-0 prompt reconstruction, prompt calibration and analysis activities, for re-reconstruction at Tier-1s and for release validation. At the present usage level the servers currently handle in total around a million authenticated HTTP requests per day. We describe the main features and components of the system, our implementation for web-based interactive rendering, and the server design. We give an overview of the deployment and maintenance procedures. We discuss the main technical challenges and our solutions to them, with emphasis on functionality, long-term robustness and performance.

  13. CMS data quality monitoring web service

    Science.gov (United States)

    Tuura, L.; Eulisse, G.; Meyer, A.

    2010-04-01

    A central component of the data quality monitoring system of the CMS experiment at the Large Hadron Collider is a web site for browsing data quality histograms. The production servers in data taking provide access to several hundred thousand histograms per run, both live in online as well as for up to several terabytes of archived histograms for the online data taking, Tier-0 prompt reconstruction, prompt calibration and analysis activities, for re-reconstruction at Tier-1s and for release validation. At the present usage level the servers currently handle in total around a million authenticated HTTP requests per day. We describe the main features and components of the system, our implementation for web-based interactive rendering, and the server design. We give an overview of the deployment and maintenance procedures. We discuss the main technical challenges and our solutions to them, with emphasis on functionality, long-term robustness and performance.

  14. Silicon detectors for the n-TOF neutron beams monitoring

    CERN Document Server

    Cosentino, L; Barbagallo, M; Colonna, N; Damone, L; Pappalardo, A; Piscopo, M; Finocchiaro, P

    2015-01-01

    During 2014 the second experimental area EAR2 was completed at the n-TOF neutron beam facility at CERN. As the neutrons are produced via spallation, by means of a high-intensity 20 GeV pulsed proton beam impinging on a thick target, the resulting neutron beam covers an enormous energy range, from thermal to several GeV. In this paper we describe two beam diagnostic devices, designed and built at INFN-LNS, both exploiting silicon detectors coupled with neutron converter foils containing 6Li. The first one is based on four silicon pads and allows to monitor the neutron beam flux as a function of the neutron energy. The second one, based on position sensitive silicon detectors, is intended for the reconstruction of the beam profile, again as a function of the neutron energy. Several electronic setups have been explored in order to overcome the issues related to the gamma flash, namely a huge pulse present at the start of each neutron bunch which may blind the detectors for some time. The two devices have been ch...

  15. Performance of MACACO Compton telescope for ion-beam therapy monitoring : first test with proton beams

    NARCIS (Netherlands)

    Solevi, Paola; Munoz, Enrique; Solaz, Carles; Trovato, Marco; Dendooven, Peter; Gillam, John E.; Lacasta, Carlos; Oliver, Josep F.; Rafecas, Magdalena; Torres-Espallardo, Irene; Llosa, Gabriela

    2016-01-01

    In order to exploit the advantages of ion-beam therapy in a clinical setting, delivery verification techniques are necessary to detect deviations from the planned treatment. Efforts are currently oriented towards the development of devices for real-time range monitoring. Among the different detector

  16. Off-axis beam quality change in linear accelerator x-ray beams

    International Nuclear Information System (INIS)

    The effective energy of the x-ray beam from linear accelerators changes as a function of the position in the beam due to nonuniform filtration by the flattening filter. In this work, the transmittance through a water column was measured in good geometry and the beam quality characterized in units of HVL in water. Measurements were made on a variety of linear accelerators from 4 to 10 MV. The beam energy decreased with increasing distance from the central ray for all accelerators measured

  17. Plasma Charge Current for Controlling and Monitoring Electron Beam Welding with Beam Oscillation

    Science.gov (United States)

    Trushnikov, Dmitriy; Belenkiy, Vladimir; Shchavlev, Valeriy; Piskunov, Anatoliy; Abdullin, Aleksandr; Mladenov, Georgy

    2012-01-01

    Electron beam welding (EBW) shows certain problems with the control of focus regime. The electron beam focus can be controlled in electron-beam welding based on the parameters of a secondary signal. In this case, the parameters like secondary emissions and focus coil current have extreme relationships. There are two values of focus coil current which provide equal value signal parameters. Therefore, adaptive systems of electron beam focus control use low-frequency scanning of focus, which substantially limits the operation speed of these systems and has a negative effect on weld joint quality. The purpose of this study is to develop a method for operational control of the electron beam focus during welding in the deep penetration mode. The method uses the plasma charge current signal as an additional informational parameter. This parameter allows identification of the electron beam focus regime in electron-beam welding without application of additional low-frequency scanning of focus. It can be used for working out operational electron beam control methods focusing exactly on the welding. In addition, use of this parameter allows one to observe the shape of the keyhole during the welding process. PMID:23242276

  18. Optical Beam Timing Monitor Experiments at the Advanced Light Source

    International Nuclear Information System (INIS)

    We present the initial results of an experimental study of a beam timing monitor based on an optoelectronic technique. This technique uses the electrical signal from a beam position monitor to modulate the amplitude of a train of laser pulses, converting timing jitter into an amplitude jitter. This modulation is then measured with a photodetector and sampled by a fast ADC. This approach has already demonstrated sub-100fs resolution and promises even better results. Additionally, we are planning to use the technique as a way to extract the maximum possible bandwidth from a BPM, avoiding the dispersion typical of long RF cables. We show our initial results using signals from the Advanced Light Source storage ring

  19. Configuration and Validation of the LHC Beam Loss Monitoring System

    CERN Document Server

    Zamantzas, C; Emery, J; Fitzek, J; Follin, F; Jackson, S; Kain, V; Kruk, G; Misiowiec, M; Roderick, C; Sapinski, M

    2009-01-01

    The LHC Beam Loss Monitoring (BLM) system is one of the most complex instrumentation systems deployed in the LHC. As well as protecting the machine, the system is also used as a means of diagnosing machine faults, and providing feedback of losses to the control room and several systems such as the Collimation, the Beam Dump and the Post-Mortem. The system has to transmit and process signals from over 4’000 monitors, and has approaching 3 million configurable parameters. This paper describes the types of configuration data needed, the means used to store and deploy all the parameters in such a distributed system and how operators are able to alter the operating parameters of the system, particularly with regard to the loss threshold values. The various security mechanisms put in place, both at the hardware and software level, to avoid accidental or malicious modification of these BLM parameters are also shown for each case.

  20. Accelerator Physics Experiments with Beam Loss Monitors at BESSY

    CERN Document Server

    Kuske, P

    2001-01-01

    The extended use of beam loss monitoring has led to a better understanding of the linear and non-linear physics involved in the single and multiple particle dynamics at BESSY. This knowledge has been used for improving the performance of the light source in terms of lifetime, beam stability, and stability of the energy. The key to these experiments are loss monitors placed at strategic locations of the ring with high sensitivity to Touschek or Coulomb scattered particles. Coulomb-scattering depends strongly on the transverse dynamics which is determined by the magnetic guiding fields. Losses occur primarily at the vertical aperture restrictions imposed by the flat insertion device vacuum chambers. Tune scan measurements clearly show resonances produced by the lattice magnets and by some of the insertion devices. Touschek scattering depends on the 3-dimensional electron density and the spins of the colliding particles. In transfer function type experiments these dependencies have been used to observe the effec...

  1. Neutron beam monitor based on a boron-coated GEM

    Institute of Scientific and Technical Information of China (English)

    ZHOU Jian-Rong; LI Yi; SUN Zhi-Jia; LIU Ben; WANG Yan-Feng; YANG Gui-An; ZHOU Liang; XU Hong; DONG Jing; YANG Lei

    2011-01-01

    A new thermal neutron beam monitor with a Gas Electron Multiplier (GEM) is developed to meet the needs of the next generation of neutron facilities. A prototype chamber has been constructed with two 100 mm×100 mm GEM foils. Enriched boron-10 is coated on one surface of the aluminum cathode plate as the neutron convertor. 96 channel pads with an area of 8 mm×8 mm each are used for fast signal readout.In order to study the basic characteristics of a boron-coated GEM, several irradiation tests were carried out with α source 239pu and neutron source 241Am(Be). The signal induced by the neutron source has a high signal-to-noise ratio. A clear image obtained from α source 239pu is presented, which shows that the neutron beam monitor based on a boron-coated GEM has a good two-dimensional imaging ability.

  2. Performance of a High Resolution Cavity Beam Position Monitor System

    Energy Technology Data Exchange (ETDEWEB)

    Walston, S; Boogert, S; Chung, C; Fitsos, P; Frisch, J; Gronberg, J; Hayano, H; Honda, Y; Kolomensky, Y; Lyapin, A; Malton, S; May, J; McCormick, D; Meller, R; Miller, D; Orimoto, T; Ross, M; Slater, M; Smith, S; Smith, T; Terunuma, N; Thomson, M; Urakawa, J; Vogel, V; Ward, D; White, G

    2006-12-18

    It has been estimated that an RF cavity Beam Position Monitor (BPM) could provide a position measurement resolution of less than one nanometer. We have developed a high resolution cavity BPM and associated electronics. A triplet comprised of these BPMs was installed in the extraction line of the Accelerator Test Facility (ATF) at the High Energy Accelerator Research Organization (KEK) for testing with its ultra-low emittance beam. The three BPMs were each rigidly mounted inside an alignment frame on six variable-length struts which could be used to move the BPMs in position and angle. We have developed novel methods for extracting the position and tilt information from the BPM signals including a robust calibration algorithm which is immune to beam jitter. To date, we have demonstrated a position resolution of 15.6 nm and a tilt resolution of 2.1 {micro}rad over a dynamic range of approximately {+-} 20 {micro}m.

  3. Performance of a High Resolution Cavity Beam Position Monitor System

    Energy Technology Data Exchange (ETDEWEB)

    Walston, Sean; Boogert, Stewart; Chung, Carl; Fitsos, Joe; Frisch, Joe; Gronberg, Jeff; Hayano, Hitoshi; Honda, Yosuke; Kolomensky, Yury; Lyapin, Alexey; Malton, Stephen; May, Justin; McCormick, Douglas; Meller, Robert; Miller, David John; Orimoto, Toyoko; Ross, Marc; Slater, Mark; Smith, Steve; Smith, Tonee; Terunuma, Nobuhiro; /Fermilab /UC,

    2007-06-08

    It has been estimated that an RF cavity Beam Position Monitor (BPM) could provide a position measurement resolution of less than one nanometer. We have developed a high resolution cavity BPM and associated electronics. A triplet comprised of these BPMs was installed in the extraction line of the Accelerator Test Facility (ATF) at the High Energy Accelerator Research Organization (KEK) for testing with its ultra-low emittance beam. The three BPMs were each rigidly mounted inside an alignment frame on six variable-length struts which could be used to move the BPMs in position and angle. We have developed novel methods for extracting the position and tilt information from the BPM signals including a robust calibration algorithm which is immune to beam jitter. To date, we have demonstrated a position resolution of 15.6 nm and a tilt resolution of 2.1 {mu}rad over a dynamic range of approximately {+-} 20 {mu}m.

  4. Extracting source parameters from beam monitors on a chopper spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Abernathy, Douglas L [ORNL; Niedziela, Jennifer L [ORNL; Stone, Matthew B [ORNL

    2015-01-01

    The intensity distributions of beam monitors in direct-geometry time-of-flight neutron spectrometers provide important information about the instrument resolution. For short-pulse spallation neutron sources in particular, the asymmetry of the source pulse may be extracted and compared to Monte Carlo source simulations. An explicit formula using a Gaussian-convolved Ikeda-Carpenter distribution is given and compared to data from the ARCS instrument at the Spallation Neutron Source.

  5. Cherenkov detector for beam quality measurement

    Science.gov (United States)

    Orfanelli, S.

    2016-07-01

    A new detector to measure the machine induced background at larger radii has been developed and installed in the CMS experiment at the LHC. It consists of forty modules, each comprising a quartz bar read out by a photomultiplier tube. Since Cherenkov radiation is emitted in a forward cone around the charged particle trajectory, these detectors can distinguish between the arrival directions of the machine induced background and the collision products. The back-end electronics consists of a uTCA readout with excellent time resolution. The installation in the CMS is described and first commissioning measurements with the LHC beams in Run II are presented.

  6. Profile Monitors for Wide Multiplicity Range Electron Beams

    CERN Document Server

    Buonomo, B; Quintieri, L

    2005-01-01

    The DAFNE Beam Test Facility (BTF) provides electron and positron beams in a wide range of intensity, from single particle up to 1010 particles per pulse, and energy, from a few tens of MeV up to 800 MeV. The pulse time width can be adjusted between 1 and 10 ns and the maximum repetition rate is 50 Hz. The large range of operation of the facility requires the implementation of different beam profile and multiplicity monitors. In the single particle operation mode the beam spot profile and position are measured by a x-y scintillating fiber system with millimetric resolution and multi-anode PMT readout. From a few tens up to 106-107 particles per pulse, a silicon chamber made of two 9.5x9.5 cm2 wide 400μm thick silicon strip detectors organized in a x-y configuration with a pitch of 121μm has been developed. Once calibrated, the system can be used also as an intensity monitor. The description of the devices and the results obtained during the data taking periods of several experiments at the...

  7. Performance of a reentrant cavity beam position monitor

    Energy Technology Data Exchange (ETDEWEB)

    Simon, C.; Luong, M.; Chel, S.; Napoly, O.; Novo, J.; Roudier, D. [CEA Saclay, DSM, Irfu, SACM, F-91191 Gif Sur Yvette, (France); Rouviere, N. [CNRS, IN2P3-IPN, F-91406 Orsay, (France); Baboi, N.; Mildner, N.; Nolle, D. [DESY, D-22603 Hamburg, (Germany)

    2008-07-01

    The beam-based alignment and feedback systems, essential operations for the future colliders, require high resolution beam position monitors (BPMs). In the framework of the European CARE/SRF program, a reentrant cavity BPM with its associated electronics was developed by the CEA/DSM/Irfu in collaboration with DESY. The design, the fabrication, and the beam test of this monitor are detailed within this paper. This BPM is designed to be inserted in a cryo-module, work at cryogenic temperature in a clean environment. It has achieved a resolution better than 10 {mu}m and has the possibility to perform bunch to bunch measurements for the X-ray free electron laser (X-FEL) and the International Linear Collider (ILC). Its other features are a small size of the rf cavity, a large aperture (78 mm), and an excellent linearity. A first prototype of a reentrant cavity BPM was installed in the free electron laser in Hamburg (FLASH), at Deutsches Elektronen-Synchrotron (DESY) and demonstrated its operation at cryogenic temperature inside a cryo-module. The second, installed, also, in the FLASH linac to be tested with beam, measured a resolution of approximately 4 {mu}m over a dynamic range {+-} 5 mm in single bunch. (authors)

  8. A beam position monitor system for electron cooler in HIRFL-CSR

    International Nuclear Information System (INIS)

    The efficient electron cooling requires that the ion beam and electron beam are parallel and overlapped. In order to measure the positions of ion beam and electron beam simultaneously, a beam position monitor system is developed for the HIRFL-CSR electron cooler device, which probe consists of four capacitive cylinder linear-cut poles. One can get the both beam positions from the picking up signals of four poles by using Fourier transform (FFT) method. The measurement results show that the beam position monitor system is accurate. This system is suitable for investigating the relation between electron cooling processing and the angle of ion beam and electron beam. (authors)

  9. Application of Diamond Based Beam Loss Monitors at LHC

    CERN Document Server

    Hempel, Maria; Rüdiger, S.

    2013-05-14

    The Large Hadron Collider (LHC) was conceived in the 1980s and started the operation in 2008. It needed more than 20 years to plan and construct this accelerator and its experiments. Four main experiments are located around the ring, Compact Muon Solenoid (CMS), A Toroidal LHC Apparatus (ATLAS), A Large Ion Collider Experiment (ALICE) and LHC beauty (LHCb). Two beams that traveling in opposite direction in the LHC tunnel, collide in each of the experiments. The navigation of the beams is done by over 10000 magnets and each beam has a stored energy of 362MJ which correspond to the kinetic energy of a train like the TGV travelling of 150km/h. Only a small percentage of that energy can damage the material in the LHC ring or the magnets. This would mean a repair time of months or years, without taking any data. To avoid such a scenario, it is important to monitor the beam condition and measure the amount of losses of the beam. Such losses can for example happen due to dust particles in the vacuum chambers or due...

  10. Measurement system with high accuracy for laser beam quality.

    Science.gov (United States)

    Ke, Yi; Zeng, Ciling; Xie, Peiyuan; Jiang, Qingshan; Liang, Ke; Yang, Zhenyu; Zhao, Ming

    2015-05-20

    Presently, most of the laser beam quality measurement system collimates the optical path manually with low efficiency and low repeatability. To solve these problems, this paper proposed a new collimated method to improve the reliability and accuracy of the measurement results. The system accuracy controlled the position of the mirror to change laser beam propagation direction, which can realize the beam perpendicularly incident to the photosurface of camera. The experiment results show that the proposed system has good repeatability and the measuring deviation of M2 factor is less than 0.6%. PMID:26192526

  11. Study on the Beam Quality of Uncoupled Laser Diode Arrays

    Institute of Scientific and Technical Information of China (English)

    GAO Chunqing; WEI Guanghui

    2001-01-01

    The beam quality of uncoupled laser diode array is studied theoretically and experimentally. By calculating the second order moments of the beam emitted from the laser diode array, the dependence of the M2-factor of the laser diode array on the M2-factor of the single emitter, the ratio of the emitting region to the non-emitting space, and the number of emitters, has been deduced. From the measurement of the beam propagation the M2-factor of a laser diode bar is experimentally determined. The measured M2-factor of the laser diode bar agrees with the theoretical prediction.

  12. Patient doses and image quality in chest radiography: The influence of different beam qualities

    OpenAIRE

    Ciraj-Bjelac Olivera; Lončar Milan; Košutić Duško; Kovačević Milojko; Aranđić Danijela

    2007-01-01

    A simple method of assessing optimal X-ray beam quality in respect to patient exposure and image quality in chest screen-film radiography is presented here. Different beam qualities were generated by the use of various combinations of tube voltages (70 kV to 110 kV) and Al and Cu filter thick nesses. Patient doses were assessed by kerma-area product measurements. Simultaneously, image quality was evaluated by a twofold method: a clinical study applying European quality criteria for the radiog...

  13. Sidewall quality in proton beam writing

    Energy Technology Data Exchange (ETDEWEB)

    Chiam, S.Y. [Center for Ion Beam Applications, Department of Physics, National University of Singapore, 2, Science Drive 3, Singapore 117542 (Singapore)]. E-mail: phycsy@nus.edu.sg; Kan, J.A. van [Center for Ion Beam Applications, Department of Physics, National University of Singapore, 2, Science Drive 3, Singapore 117542 (Singapore); Osipowicz, T. [Center for Ion Beam Applications, Department of Physics, National University of Singapore, 2, Science Drive 3, Singapore 117542 (Singapore); Udalagama, C.N.B. [Center for Ion Beam Applications, Department of Physics, National University of Singapore, 2, Science Drive 3, Singapore 117542 (Singapore); Watt, F. [Center for Ion Beam Applications, Department of Physics, National University of Singapore, 2, Science Drive 3, Singapore 117542 (Singapore)

    2007-07-15

    Proton beam writing has been shown to allow the fabrication of high aspect ratio nanostructures at sub-100 nm dimension and with smooth and vertical sidewalls. For applications such as the fabrication of waveguides, sidewall smoothness is an important issue. We report results from investigations into side wall roughness measured directly with Atomic Force Microscopy. Structures were written in bulk poly(methylmethacrylate) (PMMA) with 2 MeV protons specifically to allow side access. We studied the effects of different scanning algorithms and also the variation of wall roughness with development time and ion penetration depth. Our results indicate that sidewall rms roughness of less than 7 nm is readily achievable. Multi-loop scanning and optimization of the scanning algorithm can lead to significant improvements in sidewall smoothness.

  14. Sidewall quality in proton beam writing

    International Nuclear Information System (INIS)

    Proton beam writing has been shown to allow the fabrication of high aspect ratio nanostructures at sub-100 nm dimension and with smooth and vertical sidewalls. For applications such as the fabrication of waveguides, sidewall smoothness is an important issue. We report results from investigations into side wall roughness measured directly with Atomic Force Microscopy. Structures were written in bulk poly(methylmethacrylate) (PMMA) with 2 MeV protons specifically to allow side access. We studied the effects of different scanning algorithms and also the variation of wall roughness with development time and ion penetration depth. Our results indicate that sidewall rms roughness of less than 7 nm is readily achievable. Multi-loop scanning and optimization of the scanning algorithm can lead to significant improvements in sidewall smoothness

  15. A Water Quality Monitoring Programme for Schools and Communities

    Science.gov (United States)

    Spellerberg, Ian; Ward, Jonet; Smith, Fiona

    2004-01-01

    A water quality monitoring programme for schools is described. The purpose of the programme is to introduce school children to the concept of reporting on the "state of the environment" by raising the awareness of water quality issues and providing skills to monitor water quality. The programme is assessed and its relevance in the context of…

  16. Single Pass Stripline Beam Position Monitor Design, Fabrication and Commissioning

    Science.gov (United States)

    Tan, Y.-R. E.; Wang, D.; Van Garderen, E.; McKinlay, J.

    2012-10-01

    To monitor the position of the electron beam during transport from the Booster Synchrotron to the Storage Ring at the Australian Synchrotron, a stripline Beam Position Monitor (BPM) has been designed, fabricated and installed in-house. The design was based on an existing stripline in the Booster and modified for the transfer line with a particular emphasis on ensuring the line impedance is properly matched to the detector system. The initial bench tests of a prototype stripline showed that the fabrication of the four individual striplines in the BPM was made precisely, each with a measured standing wave ratio (SWR) of 1.8 at 500 MHz. Further optimization for impedance matching will be done for new stripline BPMs. The linearity and gain factor was measured with the detector system. The detector system that digitizes the signals is an Instrumentation Technologies Brilliance Single Pass [1]. The results show an error of 1 mm at an offset (from the electrical centre) of 10 mm when a linear gain factor is assumed and an RMS noise of ~150 um that decreases to < 10 um with increasing signal intensity. The results were under our requirements for the transport line. The commissioning results of the stripline will also be presented showing a strong signal for an electron beam with an estimated integrated charge of ~50 nC with a position stability of 28 um (horizontal) and 75 um (vertical).

  17. A Fast CVD Diamond Beam Loss Monitor for LHC

    CERN Document Server

    Griesmayer, E; Dobos, D; Effinger, E; Pernegger, H

    2011-01-01

    Chemical Vapour Deposition (CVD) diamond detectors were installed in the collimation area of the CERN LHC to study their feasibility as Fast Beam Loss Monitors in a high-radiation environment. The detectors were configured with a fast, radiation-hard pre-amplifier with a bandwidth of 2 GHz. The readout was via an oscilloscope with a bandwidth of 1 GHz and a sampling rate of 5 GSPS. Despite the 250 m cable run from the detectors to the oscilloscope, single MIPs were resolved with a 2 ns rise time, a pulse width of 10 ns and a time resolution of less than 1 ns. Two modes of operation were applied. For the analysis of unexpected beam aborts, the loss profile was recorded in a 1 ms buffer and, for nominal operation, the histogram of the time structure of the losses was recorded in synchronism with the LHC period of 89.2 μs. Measurements during the LHC start-up (February to December 2010) are presented. The Diamond Monitors gave an unprecedented insight into the time structure of the beam losses resolving the 400...

  18. Cavity Beam Position Monitor System for ATF2

    Energy Technology Data Exchange (ETDEWEB)

    Boogert, Stewart; /Oxford U., JAI; Boorman, Gary; /Oxford U., JAI; Swinson, Christina; /Oxford U., JAI; Ainsworth, Robert; /Royal Holloway, U. of London; Molloy, Stephen; /Royal Holloway, U. of London; Aryshev, Alexander; /KEK, Tsukuba; Honda, Yosuke; /KEK, Tsukuba; Tauchi, Toshiaki; /KEK, Tsukuba; Terunuma, Nobuhiro; /KEK, Tsukuba; Urakawa, Junji; /KEK, Tsukuba; Frisch, Josef; /SLAC; May, Justin; /SLAC; McCormick, Douglas; /SLAC; Nelson, Janice; /SLAC; Smith, Tonee; /SLAC; White, Glen; /SLAC; Woodley, Mark; /SLAC; Heo, Ae-young; /Kyungpook Natl. U.; Kim, Eun-San; /Kyungpook Natl. U.; Kim, Hyoung-Suk; /Kyungpook Natl. U.; Kim, Youngim; /Kyungpook Natl. U. /University Coll. London /Kyungpook Natl. U. /Fermilab /Pohang Accelerator Lab.

    2012-07-09

    The Accelerator Test Facility 2 (ATF2) in KEK, Japan, is a prototype scaled demonstrator system for the final focus required for a future high energy lepton linear collider. The ATF2 beam-line is instrumented with a total of 38 C and S band resonant cavity beam position monitors (CBPM) with associated mixer electronics and digitizers. The current status of the BPM system is described, with a focus on operational techniques and performance. The ATF2 C-band system is performing well, with individual CBPM resolution approaching or at the design resolution of 50 nm. The changes in the CBPM calibration observed over three weeks can probably be attributed to thermal effects on the mixer electronics systems. The CW calibration tone power will be upgraded to monitor changes in the electronics gain and phase. The four S-band CBPMs are still to be investigated, the main problem associated with these cavities is a large cross coupling between the x and y ports. This combined with the large design dispersion in that degion makes the digital signal processing difficult, although various techniques exist to determine the cavity parameters and use these coupled signals for beam position determination.

  19. Single Pass Stripline Beam Position Monitor Design, Fabrication and Commissioning

    Directory of Open Access Journals (Sweden)

    McKinlay J.

    2012-10-01

    Full Text Available To monitor the position of the electron beam during transport from the Booster Synchrotron to the Storage Ring at the Australian Synchrotron, a stripline Beam Position Monitor (BPM has been designed, fabricated and installed in-house. The design was based on an existing stripline in the Booster and modified for the transfer line with a particular emphasis on ensuring the line impedance is properly matched to the detector system. The initial bench tests of a prototype stripline showed that the fabrication of the four individual striplines in the BPM was made precisely, each with a measured standing wave ratio (SWR of 1.8 at 500 MHz. Further optimization for impedance matching will be done for new stripline BPMs. The linearity and gain factor was measured with the detector system. The detector system that digitizes the signals is an Instrumentation Technologies Brilliance Single Pass [1]. The results show an error of 1 mm at an offset (from the electrical centre of 10 mm when a linear gain factor is assumed and an RMS noise of ~150 um that decreases to < 10 um with increasing signal intensity. The results were under our requirements for the transport line. The commissioning results of the stripline will also be presented showing a strong signal for an electron beam with an estimated integrated charge of ~50 nC with a position stability of 28 um (horizontal and 75 um (vertical.

  20. Test of the LHC DIAMOND Beam Loss Monitors

    CERN Document Server

    Dehning, B; Effinger, E; Pernegger, H; Griesmayer, E

    2011-01-01

    Chemical Vapour Deposition(CVD) diamond detectors were installed in the collimation area of the CERN LHC to study their feasibility as Fast Beam Loss Monitors in a high-­radiation environment. Four detectors were configured with fast, radiation-­hard pre-amplifiers with a bandwidth of 2GHz. The readout was via an oscilloscope with a bandwidth of 1GHz and a sampling rate of 5 GSPS. Despite the 250m cable run from the detectors to the oscilloscope, particle losses were resolved with a 2ns rise time, a pulse width of 10ns and a time resolution of 615ps. Two modes of operation were applied. For the analysis of unexpected beam aborts, the loss profile was recorded in a 1ms buffer and, for nominal operation, the histogram of the time structure of the losses was recorded in synchronism with the LHC period of 89.2us. Measurements during the LHC start-­up (February to December 2010) are presented. The Diamond Monitors gave an unprecedented insight into the time structure of the beam losses resolving the LHC RF freq...

  1. Beam position monitor system of J-PARC RCS

    International Nuclear Information System (INIS)

    The J-PARC RCS is a 25 Hz Rapid-Cycling proton Synchrotron and its designed beam power is 1 MW. The beam position monitor (BPM) system at J-PARC RCS is described in this paper. The pre-defined diameter of the BPM detectors is larger than 250 mm, however, the system has to measure the beam position very accurately. In addition, it is necessary to have a large dynamic range. The system should work not only for the high intensity but also for low intensity, such as during beam commissioning, when the intensity is below 1% of the design intensity. There are 54 BPM detectors around the ring and most of them are placed inside steering magnets because of quite limited space. The BPM detector is an electro-static type and it has four electrodes, and a pair of electrodes gives a good linear response with a diagonal cut shape to detect the charge center precisely. The signal processing units, which are equipped with 14-bit 40 MS/s ADC and 600 MHz DSP, have been developed. They are accessed via shared memory space and controlled by EPICS. Such a processing unit is capable of recording the full 25 Hz pulse data for the so-called “COD mode” (averaged beam position calculation) and it can also store the whole waveform data for further analysis, like turn-by-turn position calculation. The resolution was estimated to be 20μm for “COD mode” and to be 0.3 mm for the turn-by-turn mode with relatively low intensity of 8×1011ppp. The position accuracy is estimated to be about 0.5 mm using a newly developed Beam Based Alignment (BBA) method.

  2. Capacitive beam position monitors for the low-β beam of the Chinese ADS proton linac

    Science.gov (United States)

    Zhang, Yong; Wu, Jun-Xia; Zhu, Guang-Yu; Jia, Huan; Xue, Zong-Heng; Zheng, Hai; Xie, Hong-Ming; Kang, Xin-Cai; He, Yuan; Li, Lin; Denard, Jean Claude

    2016-02-01

    Beam Position Monitors (BPMs) for the low-β beam of the Chinese Accelerator Driven Subcritical system (CADS) Proton linac are of the capacitive pick-up type. They provide higher output signals than that of the inductive type. This paper will describe the design and tests of the capacitive BPM system for the low-β proton linac, including the pick-ups, the test bench and the read-out electronics. The tests done with an actual proton beam show a good agreement between the measurements and the simulations in the time domain. Supported by National Natural Science Foundation of China (11405240) and “Western Light” Talents Training Program of Chinese Academy of Sciences

  3. Thin silicon strip detectors for beam monitoring in Micro-beam Radiation Therapy

    CERN Document Server

    Povoli, Marco; Bravin, Alberto; Cornelius, Iwan; Bräuer-Krisch, Elke; Fournier, Pauline; Hansen, Thor-Erik; Kok, Angela; Lerch, Michael; Monakhov, Edouard; Morse, John; Petasecca, Marco; Requardt, Herwig; Rosenfeld, Anatoly; Röhrich, Dieter; Sandaker, Heidi; Salomé, Murielle; Stugu, Bjarne

    2015-01-01

    Microbeam Radiation Therapy (MRT) is an emerging cancer treatment that is currently being developed at the European Synchrotron Radiation Facility (ESRF) in Grenoble, France. This technique uses a highly collimated and fractionated X-ray beam array with extremely high dose rate and very small divergence, to benefit from the dose-volume effect, thus sparing healthy tissue. In case of any beam anomalies and system malfunctions, special safety measures must be installed, such as an emergency safety shutter that requires continuous monitoring of the beam intensity profile. Within the 3DMiMic project, a novel silicon strip detector that can tackle the special features of MRT, such as the extremely high spatial resolution and dose rate, has been developed to be part of the safety shutter system. The first prototypes have been successfully fabricated, and experiments aimed to demonstrate their suitability for this unique application have been performed. Design, fabrication and the experimental results as well as any...

  4. Development of KOMAC Beam Monitoring System Using EPICS

    International Nuclear Information System (INIS)

    The beam loss signals must be digitized and the sampling has to be synchronized to a reference signal which is an external trigger for beam operation. The digitized data must be accessible by the Experimental Physics and Industrial Control System (EPICS)-based control system, which manages the whole accelerator control. In order to satisfy the requirement, an Input /Output Controller (IOC), which runs Linux on a CPU module with PCI express based Analog to Digital Converter (ADC) modules, has been adopted. An associated linux driver and EPICS device support module also have been developed. The IOC meets the requirements and the development and maintenance of the software for the IOC is considerably efficient. The data acquisition system running EPICS will be used in increasing phase of KOrea Multi-purpose Accelerator Complex (KOMAC) beam power. The beam monitoring system integrates BLM and BPM signals into control system and offers real-time data to operators. The IOC, which is implemented with Linux and PCI driver, has supported data acquisition as a very flexible solution

  5. Development of KOMAC Beam Monitoring System Using EPICS

    Energy Technology Data Exchange (ETDEWEB)

    Song, Young-Gi; Yun, Sang-Pil; Kim, Han-Sung; Kwon, Hyeok-Jung; Cho, Yong-Sub [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-10-15

    The beam loss signals must be digitized and the sampling has to be synchronized to a reference signal which is an external trigger for beam operation. The digitized data must be accessible by the Experimental Physics and Industrial Control System (EPICS)-based control system, which manages the whole accelerator control. In order to satisfy the requirement, an Input /Output Controller (IOC), which runs Linux on a CPU module with PCI express based Analog to Digital Converter (ADC) modules, has been adopted. An associated linux driver and EPICS device support module also have been developed. The IOC meets the requirements and the development and maintenance of the software for the IOC is considerably efficient. The data acquisition system running EPICS will be used in increasing phase of KOrea Multi-purpose Accelerator Complex (KOMAC) beam power. The beam monitoring system integrates BLM and BPM signals into control system and offers real-time data to operators. The IOC, which is implemented with Linux and PCI driver, has supported data acquisition as a very flexible solution.

  6. Preparation of a beam quality indicator for effective energy determinations of continuum beams: establishment of traceability

    CERN Document Server

    Matsubayashi, M; Kobayashi, H

    1999-01-01

    A new beam quality indicator (BQI) was designed and fabricated to determine effective energies of beams extracted from neutron radiography facilities. Performances of the five new BQIs were compared with the original BQI which was recently proposed and tested by various beams. Non-filtered thermal neutrons, filtered thermal neutrons, and cold neutrons from a guide tube were used in the performance test program. The new BQIs were also examined by four different detection systems using a combination of a Gd converter and a X-ray film, a neutron imaging plate, a cooled charge coupled device camera, and a silicon intensified target tube camera.

  7. Experimental characterization of beam quality of a Yb:YAG thin disk laser

    Science.gov (United States)

    Kazemi, S.; Mahdieh, M. H.

    2015-02-01

    In this paper we investigate the effects of cooling water temperature and pumping diode laser beam profile on the disk laser beam quality. The results show that both issues are important and can influence the beam quality but at the conditions of our experiment these issues do not affect the beam quality significantly.

  8. Condition monitoring for a neutral beam injector cryopumping system

    Energy Technology Data Exchange (ETDEWEB)

    Wright, N., E-mail: n.wright@lboro.ac.uk [School of Electronic and Electrical Engineering, Loughborough University, Loughborough LE11 3TU (United Kingdom); Dixon, R., E-mail: r.dixon@lboro.ac.uk [School of Electronic and Electrical Engineering, Loughborough University, Loughborough LE11 3TU (United Kingdom); Verhoeven, R., E-mail: roel.verhoeven@ccfe.ac.uk [JET-EFDA, Culham Science Centre, Abingdon OX14 3DB (United Kingdom)

    2013-10-15

    Highlights: ► The development of a cryopumping condition monitoring scheme is presented. ► A residual generation scheme is used to detect two faults. ► Kalman filtering is used to generate the residuals. ► A filtering and voting arrangement is used to evaluate the residuals. ► A non-linear simulation model is used to verify the scheme. -- Abstract: For neutral beam injection systems, the maintenance of a vacuum inside the injector box is essential for normal operation. Cryogenic pumping systems are often used to create and maintain this vacuum. Cryogenic pumping systems have been deployed on the neutral beam heating systems supporting the Joint European Torus. With these as a target application, the development of a condition monitoring scheme is presented. The scheme uses a residual generation approach. A bank of Kalman filters is used to estimate measured process variables. A residual evaluator is used to map residual signals onto a set of faults. Two example faults are simulated to demonstrate the response of the scheme. This paper contributes to the wider fusion development programme by demonstrating how a contemporary condition monitoring technique can be applied to a fusion support system, in order to improve its availability.

  9. Performance of MACACO Compton telescope for ion-beam therapy monitoring: first test with proton beams

    Science.gov (United States)

    Solevi, Paola; Muñoz, Enrique; Solaz, Carles; Trovato, Marco; Dendooven, Peter; Gillam, John E.; Lacasta, Carlos; Oliver, Josep F.; Rafecas, Magdalena; Torres-Espallardo, Irene; Llosá, Gabriela

    2016-07-01

    In order to exploit the advantages of ion-beam therapy in a clinical setting, delivery verification techniques are necessary to detect deviations from the planned treatment. Efforts are currently oriented towards the development of devices for real-time range monitoring. Among the different detector concepts proposed, Compton cameras are employed to detect prompt gammas and represent a valid candidate for real-time range verification. We present the first on-beam test of MACACO, a Compton telescope (multi-layer Compton camera) based on lanthanum bromide crystals and silicon photo-multipliers. The Compton telescope was first characterized through measurements and Monte Carlo simulations. The detector linearity was measured employing 22Na and Am-Be sources, obtaining about 10% deviation from linearity at 3.44 MeV. A spectral image reconstruction algorithm was tested on synthetic data. Point-like sources emitting gamma rays with energy between 2 and 7 MeV were reconstructed with 3–5 mm resolution. The two-layer Compton telescope was employed to measure radiation emitted from a beam of 150 MeV protons impinging on a cylindrical PMMA target. Bragg-peak shifts were achieved via adjustment of the PMMA target location and the resulting measurements used during image reconstruction. Reconstructed Bragg peak profiles proved sufficient to observe peak-location differences within 10 mm demonstrating the potential of the MACACO Compton Telescope as a monitoring device for ion-beam therapy.

  10. Monitoring relativistic heavy ion beams at the Bevalac

    International Nuclear Information System (INIS)

    Beam fluence in high intensity proton and electron accelerators is usually measured with Secondary Emission Monitors (SEM) calibrated by an activation method. These were no such activation measurements available for relativistic heavy ion beams. Secondary electron production and energy loss of a charged particle in passing through material are a result of Coulomb interaction between the projectile field and electrons in the material. Therefore range measurements and secondary emission yield should follow the same functional relationship of velocity and charge as given by the Bethe-Bloch equation. A substantial amount of data on range in water for various ions has been collected at the Bevalac Biomedical facility. Using the same calculations that convert measured proton ranges to ion ranges and comparing the calculated values to measured values, provides an indirect way to verify the validity of the SEM calibration. The results of these measurements are discussed in this paper

  11. Summary of the 2014 Beam-Halo Monitoring Workshop

    Energy Technology Data Exchange (ETDEWEB)

    Fisher, Alan

    2015-09-25

    Understanding and controlling beam halo is important for high-intensity hadron accelerators, for high-brightness electron linacs, and for low-emittance light sources. This can only be achieved by developing suitable diagnostics. The main challenge faced by such instrumentation is the high dynamic range needed to observe the halo in the presence of an intense core. In addition, measurements must often be made non-invasively. This talk summarizes the one-day workshop on Beam-Halo Monitoring that was held at SLAC on September 19 last year, immediately following IBIC 2014 in Monterey. Workshop presentations described invasive techniques using wires, screens, or crystal collimators, and non-invasive measurements with gas or scattered electrons. Talks on optical methods showed the close links between observing halo and astronomical problems like observing the solar corona or directly observing a planet orbiting another star.

  12. Quality Assurance Project Plan for Facility Effluent Monitoring Plan activities

    International Nuclear Information System (INIS)

    This Quality Assurance Project Plan addresses the quality assurance requirements for the activities associated with the Facility Effluent Monitoring Plans, which are part of the overall Hanford Site Environmental Protection Plan. This plan specifically applies to the sampling and analysis activities and continuous monitoring performed for all Facility Effluent Monitoring Plan activities conducted by Westinghouse Hanford Company. It is generic in approach and will be implemented in conjunction with the specific requirements of the individual Facility Effluent Monitoring Plans

  13. Tritium Monitoring in the ITER Neutral Beam Test Facility

    International Nuclear Information System (INIS)

    The proposed ITER Neutral Beam Test Facility (NBTF) is designed to operate with negative ion neutral injectors in order to provide the required beam power and efficiency. The operation of the neutral beam test bed involves the firing of a beam of deuterons into a calorimeter. The deuterons will become embedded in the calorimeter and subsequent particles can be involved in deuterium fusion reactions. There are two branches of this reaction which have approximately equal probability. These are: D + D → 3He + n D + D → 3H + p Because of this relationship, it is possible to estimate the level of tritium production accurately by measuring the neutron production. The proposed testing campaign will generate an annual tritium discharge to the atmosphere of about 246 GBq. An absolutely calibrated neutron monitor is needed for tritium accounting but difficulties arise because the neutron source is complex: it is spatially extended and varying and is anisotropic. Furthermore the material of the injector will cause significant scattering of neutrons between the source and any detector. To resolve these problems it is proposed that a set of detectors is deployed around the injector and that a neutron source be placed within the injector is used to calibrate them. Very detailed Monte-Carlo calculations have been carried out to model the neutron transport thought the NBTF. All major component of the injector have been modelled. These include the calorimeter, the residual ion dump, the neutraliser, the beam source, the HV bushing and the vacuum vessel. The spatial variation of the neutron source, based on the deuteron deposition on the calorimeter and the residual ion dump has been simulated. The effects of anisotropy and the angular dependence of the neutron energy spectrum have been included. The calculations demonstrate that such a suite of detectors can be calibrated using a 252Cf source to absolutely determine the neutron and therefore the tritium production to an

  14. An Expert System Applied in Construction Water Quality Monitoring

    Directory of Open Access Journals (Sweden)

    Leila Ooshaksaraie

    2011-01-01

    Full Text Available Problem statement: An untoward environmental impact of urban growth in Malaysia has been deterioration in a number of watercourses due to severe siltation and other pollutants from the construction site. Water quality monitoring is a plan for decision makers to take into account the adverse impacts of construction activities on the receiving water bodies. It is also a process for collecting the construction water quality monitoring, baseline data and standard level. Approach: In recent years, expert systems have been used extensively in different applications areas including environmental studies. In this study, expert system software -CWQM- developed by using Microsoft Visual Basic was introduced. CWQM to be used for water quality monitoring during construction activities was designed based on the legal process in Malaysia. Results: According to the water quality monitoring regulation enacted in Malaysia, construction activities require mandatory water quality monitoring plans duly approved by Department of Environment before staring activities. CWQM primarily aims to provide educational and support system for water quality monitoring engineers and decision-makers during construction activities. It displays water quality monitoring plan in report form, water sampling location in GIS format and water quality monitoring data in graph. Conclusion: When the use of CWQM in construction water quality monitoring becomes widespread, it is highly possible that it will be benefited in terms of having more accurate and objective decisions on construction projects which are mainly focused on reducing the stormwater pollution.

  15. Numerical simulation of the PEP-II beam position monitor

    Energy Technology Data Exchange (ETDEWEB)

    Kurita, N.; Martin, D.; Ng, C.-K.; Smith, S. [Stanford Linear Accelerator Center, Menlo Park, CA (United States); Weiland, T.

    1996-08-01

    We use MAFIA to analyze the PEP-II button-type beam position monitor (BPM). Employing proper termination of the BPM into a coaxial cable, the output signal at the BPM is determined. Thus the issues of signal sensitivity and power output can be addressed quantitatively, including all transient effects and wakefields. Besides this first quantitative analysis of a true BPM 3D structure, we find that internal resonant modes are a major source of high value narrow-band impedances. The effects of these resonances on coupled-bunch instabilities are discussed. An estimate of the power dissipation in the ceramic vacuum seal under high current operation is given. (author)

  16. Simulation of PEP-II beam position monitors

    International Nuclear Information System (INIS)

    The authors use MAFIA to analyze the PEP-II button-type beam position monitors (BPMs). Employing proper termination of the BPM into a coaxial cable, the output signal at the BPM can be determined. Thus the issues of sensitivity and power output can be addressed quantitatively, including all transient effects and wakefields. Besides this first quantitative analysis of a true BPM 3D structure, they find that internal resonant modes are a major source of high value narrow-band impedances. These are evaluated and methods are presented to suppress these parasitic resonances below the tolerable limit of multibunch instabilities

  17. Beam position monitors for SuperKEKB damping ring

    International Nuclear Information System (INIS)

    Design work for the beam position monitor systems for SuperKEKB damping ring has been performed. The longitudinal and transverse impedance and the signal output of the button electrode with diameter of 6 mm were calculated using 3D electro-magnetic simulation of GdfidL. The estimated growth rate of the coupled-bunch instability was much smaller than the radiation damping rate. A turn-by-turn position detector using Log-Ratio method has also been designed and fabricated based on the estimated signal outputs. (author)

  18. Hybrid monitor for both beam position and tilt of pulsed high-current beams

    International Nuclear Information System (INIS)

    A Hybrid beam monitor, integrated with both azimuthal and axial B-dot probes, was designed for simultaneous measurement of both beam position and beam angle for pulsed high-current beams at the same location in beam pipe. The output signals of axial B-dot probes were found to be mixed with signals caused by transverse position deviation. In order to eliminate the unwanted signals, an elimination method was developed and its feasibility tested on a 50-Ω coaxial line test stand. By this method, a waveform, shape-like to that of input current and proportional to the tilt angle, was simulated and processed by following integration step to achieve the tilt angle. The tests showed that the measurement error of displacement and tilt angle less than 0.3 mm and 1.5 mrad, respectively. The latter error could be reduced with improved probes by reducing the inductance of the axial B-dot probe, but the improvement reached a limit due to some unknown systemic mechanism

  19. Beam position monitor R&D for keV ion beams

    CERN Document Server

    Naveed, S; Nosych, A; Søby,L

    2013-01-01

    Beams of cooled antiprotons at keV energies shall be provided by the Ultra-low energy Storage Ring (USR) at the Facility for Low energy Antiproton and Ion Research (FLAIR) and the Extra Low ENergy Antiproton ring (ELENA) at CERN's Antiproton Decelerator (AD) facility. Both storage rings put challenging demands on the beam position monitoring (BPM) system as their capacitive pick-ups should be capable of determining the beam position of beams at low intensities and low velocities, close to the noise level of state-of-the-art electronics. In this contribution we describe the design and anticipated performance of BPMs for low-energy ion beams with a focus on the ELENA orbit measurement systems. We also present the particular challenges encountered in the numerical simulation of pickup response at very low beta values. Finally, we provide an outlook on how the implementation of faster algorithms for the simulation of BPM characteristics could potentially help speed up such studies considerably.

  20. Development of non-contact beam intensity monitor by residual gas ionization

    International Nuclear Information System (INIS)

    Non-contact beam intensity monitor is an important device for high-intensity proton accelerator, such as J-PARC. Especially, it is difficult to measure beam intensity of DC-like beam with off-contact. We have developed non-contact beam intensity monitor for J-PARC slow-extraction beam line by measuring charge of ionization electrons in 1 Pa residual gas. In this article, specifications of the residual gas ionization current monitor (RGICM) and results of a test experiment with 65 MeV proton beam at Research Center for Nuclear Physics in Osaka University are reported. (author)

  1. Patient doses and image quality in chest radiography: The influence of different beam qualities

    Directory of Open Access Journals (Sweden)

    Ciraj-Bjelac Olivera

    2007-01-01

    Full Text Available A simple method of assessing optimal X-ray beam quality in respect to patient exposure and image quality in chest screen-film radiography is presented here. Different beam qualities were generated by the use of various combinations of tube voltages (70 kV to 110 kV and Al and Cu filter thick nesses. Patient doses were assessed by kerma-area product measurements. Simultaneously, image quality was evaluated by a twofold method: a clinical study applying European quality criteria for the radiographic technique of image on image of 126 patients and a multifunctional home-made dosimetric phantom with embedded test objects. The quantification of image quality criteria yields a simpler method of optimizing image quality and patient dose relationships. Modifications of radiographic practice, based on image quality assessment and dose measurements, resulted in significant dose reductions and preservation of image quality. Through the use of harder beam quality, dose reduction of up to a value of factor 3 were observed, compared to the doses from previously used radiographic techniques, implying that sufficient image quality does not necessarily imply higher doses. As a result of the optimization process, an optimal radiographic technique was suggested.

  2. Quality Assurance and School Monitoring in Hong Kong

    Science.gov (United States)

    Mok, Magdalena Mo Ching

    2007-01-01

    This study reports on the Hong Kong education quality assurance and school monitoring system. Three research questions were addressed: (1) Who controls the quality of school education in Hong Kong? (2) What strategies are used in the Hong Kong school education quality assurance process? (3) Agenda for Future Research on quality assurance and…

  3. Control and monitoring system for internal beam diagnostics facility of SCC

    International Nuclear Information System (INIS)

    The first Ion beam will be accelerated in K-500 Superconducting Cyclotron at VECC soon. The acceleration zone employs Main probe and Beam viewer probe for internal beam diagnostics. The ion beam, during acceleration inside the cyclotron, is needed to be maintained in median plane. The deviation of beam at various radial positions is to be monitored by Main-Probe head. The characteristics of beam e.g. size and shape information is required at the time of beam tuning. A Beam Viewer Probe, made of a borescope fitted with a fluorescent plate is used to display the beam characteristics. High resolution probe head driving systems are developed along with VB GUI to control both the drives and monitor the beam properties (e.g. magnitude, deviation, size, shape). This paper describes the control instrumentation and monitoring scheme for main probe and viewer probe. (author)

  4. National TLD network for beam calibration quality control in Colombia

    International Nuclear Information System (INIS)

    Full text: Colombia counts now with 16 linear accelerators and 24 cobalt units used for radiation therapy treatments, with a total of 60 radiation beams, and the country takes part in the IAEA/WHO International Network of Postal Dosimetry, as well as in the IAEA/WHO SSDL network. Since the country has technical capacities to develop a national quality control program, based on the SSLD and other dosimetry laboratories, with the support of the IAEA through a coordinated research project, a national network for radiotherapy beam calibration quality control was created. The network is supported by the technical infrastructure of the SSDL and the thermoluminescence dosimetry laboratory of the Nuclear Safety and Radiation Protection Unit of INGEOMINAS and an External Audit Group (EAG) conformed by 5 medical physicists, joined to radiotherapy centers of different regions of the country. The objective of the network is mainly the development of procedures for the evaluation of the beam calibration by means of thermoluminiscent (TL) powdered detectors, through the system of capsules used by the IAEA/WHO postal dosimetry audit program. The TL powder contained in the capsules is divided in 20 mg samples which are placed in metallic minicapsules for their reading. As a result of the work carried out up to now, we have established the procedures for dosimetric evaluation using a HARSHAW 4500 reader. The performance of the system and procedures were evaluated by internal trials using the secondary standard of the SSDL and with irradiation set-ups corresponding to the reference conditions for beam calibration. An uncertainty of the final result better than 2% for evaluation of doses near 2 Gy was obtained. The results of the first dosimetry quality audit exercise to national level, for evaluation of high energy photon beam calibration, are presented. The problems detected, concerning the fill-in of the forms with the information about beam calibration and capsules irradiation

  5. The LCLS Undulator Beam Loss Monitor Readout System

    Energy Technology Data Exchange (ETDEWEB)

    Dusatko, John; Browne, M.; Fisher, A.S.; Kotturi, D.; Norum, S.; Olsen, J.; /SLAC

    2012-07-23

    The LCLS Undulator Beam Loss Monitor System is required to detect any loss radiation seen by the FEL undulators. The undulator segments consist of permanent magnets which are very sensitive to radiation damage. The operational goal is to keep demagnetization below 0.01% over the life of the LCLS. The BLM system is designed to help achieve this goal by detecting any loss radiation and indicating a fault condition if the radiation level exceeds a certain threshold. Upon reception of this fault signal, the LCLS Machine Protection System takes appropriate action by either halting or rate limiting the beam. The BLM detector consists of a PMT coupled to a Cherenkov radiator located near the upstream end of each undulator segment. There are 33 BLMs in the system, one per segment. The detectors are read out by a dedicated system that is integrated directly into the LCLS MPS. The BLM readout system provides monitoring of radiation levels, computation of integrated doses, detection of radiation excursions beyond set thresholds, fault reporting and control of BLM system functions. This paper describes the design, construction and operational performance of the BLM readout system.

  6. GEM-based thermal neutron beam monitors for spallation sources

    Energy Technology Data Exchange (ETDEWEB)

    Croci, G., E-mail: Gabriele.Croci@cern.ch [Istituto di Fisica del Plasma “P. Caldirola”—CNR, Milan (Italy); Sez. INFN Milano-Bicocca, Milano (Italy); Claps, G. [Laboratori Nazionali di Frascati—INFN, Frascati (Italy); Caniello, R. [Istituto di Fisica del Plasma “P. Caldirola”—CNR, Milan (Italy); Cazzaniga, C. [Dipartimento di Fisica “G. Occhialini”, University of Milano-Bicocca (Italy); Grosso, G. [Istituto di Fisica del Plasma “P. Caldirola”—CNR, Milan (Italy); Murtas, F. [Laboratori Nazionali di Frascati—INFN, Frascati (Italy); Tardocchi, M.; Vassallo, E. [Istituto di Fisica del Plasma “P. Caldirola”—CNR, Milan (Italy); Gorini, G. [Dipartimento di Fisica “G. Occhialini”, University of Milano-Bicocca (Italy); Sez. INFN Milano-Bicocca, Milano (Italy); Horstmann, C.; Kampmann, R.; Nowak, G.; Stoermer, M. [Institute of Materials Research, Helmholtz-Zentrum Geesthacht (Germany)

    2013-12-21

    The development of new large area and high flux thermal neutron detectors for future neutron spallation sources, like the European Spallation Source (ESS) is motivated by the problem of {sup 3}He shortage. In the framework of the development of ESS, GEM (Gas Electron Multiplier) is one of the detector technologies that are being explored as thermal neutron sensors. A first prototype of GEM-based thermal neutron beam monitor (bGEM) has been built during 2012. The bGEM is a triple GEM gaseous detector equipped with an aluminum cathode coated by 1μm thick B{sub 4}C layer used to convert thermal neutrons to charged particles through the {sup 10}B(n,{sup 7}Li)α nuclear reaction. This paper describes the results obtained by testing a bGEM detector at the ISIS spallation source on the VESUVIO beamline. Beam profiles (FWHM{sub x}=31 mm and FWHM{sub y}=36 mm), bGEM thermal neutron counting efficiency (≈1%), detector stability (3.45%) and the time-of-flight spectrum of the beam were successfully measured. This prototype represents the first step towards the development of thermal neutrons detectors with efficiency larger than 50% as alternatives to {sup 3}He-based gaseous detectors.

  7. Monitoring activities in the Dutch National Air Quality Monitoring Network in 2000 and 2001

    NARCIS (Netherlands)

    Elzakker BG van; LLO

    2001-01-01

    The Dutch National Air Quality Monitoring Network (LML in Dutch) is one of the responsibilities of the Air Research Laboratory of the National Institute of Public Health and the Environment. The main objectives of the LML are to monitor ambient air quality, facilitate implementation of air quality s

  8. A beam monitor of the 2.5 GeV Bonn Electron Synchrotron

    International Nuclear Information System (INIS)

    In the present work a monitor of the Bonn 2.5 GeV Synchrotron photon beam is described. The monitor consists of a Zn S phosphor layer on a movable copper sheet which allows continuously monitoring the gamma beam position. (FKS)

  9. Combining tissue-phantom ratios to provide a beam-quality specifier for flattening filter free photon beams.

    OpenAIRE

    Dalaryd, Mårten; Knöös, Tommy; Ceberg, Crister

    2014-01-01

    There are currently several commercially available radiotherapy treatment units without a flattening filter in the beam line. Unflattened photon beams have an energy and lateral fluence distribution that is different from conventional beams and, thus, their attenuation properties differ. As a consequence, for flattening filter free (FFF) beams, the relationship between the beam-quality specifier TPR20,10 and the Spencer-Attix restricted water-to-air mass collision stopping-power ratios, L̄/ρa...

  10. Results of beam based gain calibration for beam position monitor at J-PARC Main Ring

    International Nuclear Information System (INIS)

    Beam Position Monitor (BPM) is one of the essential elements in a synchrotron facility, obtaining the circulating beam information for stabilization of the closed orbit. The accuracy of beam positions greatly affects the orbit stabilization, however, actual signal strength from a BPM depends on individuality such as 1) signal transmission for a long distance, 2) processing circuit, and 3) contact resistance at the connected parts, etc. These things cause deviations in the gain of the signal response. The gains are different from each other even in one BPM. In order to correct this relative gain deviations between electrodes, a Beam Based Gain Calibration (BBGC) method has been proposed. Development of a new method for adequate gain calibration has been an urgent issue for J-PARC Main Ring. It has been found that an analysis using Total Least Square fitting (TLS) adequately reproduces the BPM gain with sufficient accuracy. The gains obtained from the data are varied in the range of less than ±5%, and the accuracy is within ±0.6%. (author)

  11. Non-intrusive Quality Analysis of Monitoring Data

    CERN Document Server

    Brightwell, M; Suwalska, Anna

    2010-01-01

    Any large-scale operational system running over a variety of devices requires a monitoring mechanism to assess the health of the overall system. The Technical Infrastructure Monitoring System (TIM) at CERN is one such system, and monitors a wide variety of devices and their properties, such as electricity supplies, device temperatures, liquid flows etc. Without adequate quality assurance, the data collected from such devices leads to false-positives and false-negatives, reducing the effectiveness of the monitoring system. The quality must, however, be measured in a non-intrusive way, so that the critical path of the data flow is not affected by the quality computation. The quality computation should also scale to large volumes of incoming data. To address these challenges, we develop a new statistical module, which monitors the data collected by TIM and reports its quality to the operators. The statistical module uses Oracle RDBMS as the underlying store, and builds hierarchical summaries on the basic events ...

  12. Flying wire beam profile monitor at the J-PARC MR

    International Nuclear Information System (INIS)

    A flying wire beam profile monitor has been assembled and installed at the main ring of the Japan Proton Accelerator Research Complex. The monitor is to measure the horizontal beam profile using a carbon fiber of 7 μmφ. The fiber crosses the beam with the speed of 10 m/s. Secondary particles from the beam-wire scattering is detected using a scintillation counter. The scintillator signal as a function of the wire position is to be reconstructed as a beam profile. The high scanning speed and the minimum material are necessary for the accurate beam profile measurement. The monitor has been operated in the beam commissioning run of the main ring. The beam profile data have been successfully acquired after the reduction of the beam background. (author)

  13. DPSS Laser Beam Quality Optimization Through Pump Current Tuning

    Energy Technology Data Exchange (ETDEWEB)

    Omohundro, Rob; /Newport Spectra-Physics, Santa Clara; Callen, Alice; /SLAC; Sukuta, Sydney; /San Jose City Coll.

    2012-03-30

    The goal of this study is to demonstrate how a DPSS laser beam's quality parameters can be simultaneously optimized through pump current tuning. Two DPSS lasers of the same make and model were used where the laser diode pump current was first varied to ascertain the lowest RMS noise region. The lowest noise was found to be 0.13% in this region and the best M{sup 2} value of 1.0 and highest laser output power were simultaneously attained at the same current point. The laser manufacturer reported a M{sup 2} value of 1.3 and RMS noise value of .14% for these lasers. This study therefore demonstrates that pump current tuning a DPSS laser can simultaneously optimize RMS Noise, Power and M{sup 2} values. Future studies will strive to broaden the scope of the beam quality parameters impacted by current tuning.

  14. Near-facility environmental monitoring quality assurance project plan

    International Nuclear Information System (INIS)

    This Quality Assurance Project Plan addresses the quality assurance requirements for the activities associated with the preoperational and near facility environmental monitoring performed by Waste Management Federal Services, Inc., Northwest Operations and supersedes WHC-EP-0538-2. This plan applies to all sampling and monitoring activities performed by waste management Federal Services, Inc., Northwest Operations in implementing facility environmental monitoring at the Hanford Site

  15. Quality-Aware Location Monitoring for Wireless Sensor Networks

    OpenAIRE

    M.B.Raghavendra; P Harini

    2012-01-01

    Surveillance of personal locations with an untruste d system causes privacy breach/threats to the individuals those who are monitored. At this point, we propose a quality-aware locality monitoring sys tem for wireless sensor networks. In this system, we ou tline a couple of in-network location algorithms su ch as resource-aware and quality aware algorithms, aimed to provide high-end location monitoring services fo r system users with outst...

  16. RESIDUAL GAS IONIZATION BEAM PROFILE MONITOR ON 40MeV H— BEAM TRANSPORT LINE

    Institute of Scientific and Technical Information of China (English)

    徐伟鹏; E.Takasaki

    1995-01-01

    The monitor is composed of a pair of electrodes,a single stage of microchannel plate,a phosphor screen,a CCD camera and a PC computer,To obtain a good uniform collecting field,forming electrodes system is used instead of that with a resistive divider,The readout system is performed by the phosphor screen and the CCD camera because the spatial resolution is not limited by the mechanical structure like the anode strip type and such video display system is very useful for beam studies and operation of the 40MeV linac,Besides,the design and test results are described in detail.

  17. Postharvest quality of cut roses following electron-beam irradiation

    International Nuclear Information System (INIS)

    Cut Rosa x hybrida L. 'Royalty' flowers were used to determine the efficacy of electron-beam irradiation for increasing postharvest quality and decreasing petal infection by Botrytis cinerea Pers. In an experiment for determining the injury threshold, roses received electron-beam irradiation of 0, 0.5, 1, 2, and 4 kGy. Irradiation dosages greater than or equal to 4 kGy caused necrosis on petal tissue and decreased postharvest life at 20 degrees C. In a second experiment to evaluate postharvest quality, roses were irradiated at 0, 0.25, 0.5, 0.75, and 1 kGy. Dosages of 0.25 and 0.5 kGy slowed the rate of flower bud opening for 2 days but did not decrease postharvest quality when compared with nonirradiated roses. Roses that received irradiation dosages of 0.75 and 1 kGy showed unacceptable quality. In a third experiment, roses that had or had not been inoculated with B. cinerea were irradiated at 0, 0.25, 0.5, and 0.75 kGy. Irradiation did not control B. cinerea populations, and rose quality decreased as dosage increased. In a fourth experiment to determine the effect of irradiation on B. cinerea, conidia on water-agar plates exposed to dosages less than or equal to 1, 2, and 4 kGy germinated at rates of approximately 90%, 33%, and 2%, respectively, within 24 h

  18. X-ray beam qualities for dental radiology purposes

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Marcus Aurelio P. dos; Fragoso, Maria da Conceicao de F.; Lima, Ricardo de A.; Hazim, Clovis A., E-mail: masantos@cnen.gov.b, E-mail: mariacc05@yahoo.com.b, E-mail: ralima@cnen.gov.b, E-mail: chazin@cnen.gov.b [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil)

    2009-07-01

    In order to establish characteristics or properties of equipment for diagnostic radiology, e.g. ion chambers and semiconductor detectors, calibration laboratories offer a set of well-defined radiation conditions, called X-ray qualities, which can be used for many Physics studies and medical purposes. The standardization of radiation qualities has been carried out in several fields of study, but little attention has been given to the area of dental radiology, mainly for medical and physical applications using single-phase units with half-wave rectification. For this reason, a single-phase dental unit with adjustable peak voltage and tube current, called 'variable potential X-ray equipment', was developed aiming to define X-ray beam qualities for test and calibrations purposes. X-ray spectra at 50, 60 and 70 kVp were determined by using a CdTe detector and compared with those obtained for ten commercial X-ray dental units. As a result of this study, a set of X-ray qualities for the variable potential X-ray equipment was determined. The X-ray qualities spectra were utilized as reference for determination of a new set of X-ray qualities characterized for a constant potential X-ray equipment. Thus, sets of X-ray qualities were standardized and implemented in two X-ray laboratories: one with the variable potential X-ray equipment and other with constant potential X-ray equipment. These reference X-ray beam qualities should be used for test and calibration purposes involving scientific studies and services. (author)

  19. X-ray beam qualities for dental radiology purposes

    International Nuclear Information System (INIS)

    In order to establish characteristics or properties of equipment for diagnostic radiology, e.g. ion chambers and semiconductor detectors, calibration laboratories offer a set of well-defined radiation conditions, called X-ray qualities, which can be used for many Physics studies and medical purposes. The standardization of radiation qualities has been carried out in several fields of study, but little attention has been given to the area of dental radiology, mainly for medical and physical applications using single-phase units with half-wave rectification. For this reason, a single-phase dental unit with adjustable peak voltage and tube current, called 'variable potential X-ray equipment', was developed aiming to define X-ray beam qualities for test and calibrations purposes. X-ray spectra at 50, 60 and 70 kVp were determined by using a CdTe detector and compared with those obtained for ten commercial X-ray dental units. As a result of this study, a set of X-ray qualities for the variable potential X-ray equipment was determined. The X-ray qualities spectra were utilized as reference for determination of a new set of X-ray qualities characterized for a constant potential X-ray equipment. Thus, sets of X-ray qualities were standardized and implemented in two X-ray laboratories: one with the variable potential X-ray equipment and other with constant potential X-ray equipment. These reference X-ray beam qualities should be used for test and calibration purposes involving scientific studies and services. (author)

  20. SU-D-213-01: Transparent Photon Detector For The Online Monitoring Of IMRT Beams

    International Nuclear Information System (INIS)

    Purpose: An innovative Transparent Detector for Radiotherapy (TraDeRa) has been developed. The detector aims at real-time monitoring of modulated beam ahead of the patient during delivery sessions, with a field cover up to 40×40 cm 2. Methods: TraDeRa consists in a pixelated matrix of ionization chambers with a patented electrodes design. An in-house designed specific integrated circuit allows to extract the signal and provides a real-time map of beam intensity and shape, at the linac pulse-scale. The measurements under irradiation are made with a 6 MV clinical X-Ray beam. Dose calculations are performed with the Monte Carlo code PENELOPE, modeling the full accelerator head and the TraDeRa detector. Results: A 2 % attenuation of the beam was measured in the presence of TraDeRa and the PENELOPE dosimetric study showed no significant modification of the photon beam properties. TraDeRa detects error leaf position as small as 1 mm compared to a reference field, for both static and modulated fields. In addition, measurements are accurate over a large dynamic range from low intensity signals, as inter-leaves leaks, to very high intensities as obtained on the medical line of the European Synchrotron Radiation Facility. The detector is fully operational for conventional and high dose rate beams as FFF modes (up to 2400 MU/min). Conclusion: The current version of TraDeRa shows promising results for IMRT quality assurance (QA), allowing pulse-scale monitoring of the beam and high sensitivity for errors detection. The attenuation is small enough not to hinder the irradiation while keeping the beam upstream of the patient under constant control. A final prototype under development will include 1600 independent electrodes, half of them with a high resolution centered on the beam axis. This compact detector provides an independent set of measurements for a better QA. Funding support : This work was supported by the LABEX PRIMES (ANR-11-LABX-0063) of Universite de Lyon, within

  1. User-Centric Indoor Air Quality Monitoring on Mobile Devices

    OpenAIRE

    Jiang, Yifei; University of Colorado, Boulder; Li, Kun; University of Colorado, Boulder; Piedrahita, Ricardo; University of Colorado, Boulder; Yun, Xiang; University of Michigan; Tian, Lei; University of Colorado, Boulder; Mansata, Omkar M.; University of Michigan; Lv, Qin; University of Colorado, Boulder; Dick, Robert P.; University of Michigan; Hannigan, Michael; University of Colorado, Boulder; Shang, Li; University of Colorado, Boulder

    2013-01-01

    Since people spend a majority of their time indoors, indoor air quality (IAQ) can have a significant impact on human health, safety, productivity, and comfort. Due to the diversity and dynamics of people's indoor activities, it is important to monitor IAQ for each individual. Most existing air quality sensing systems are stationary or focus on outdoor air quality. In contrast, we propose MAQS, a user-centric mobile sensing system for IAQ monitoring. MAQS users carry portable, indoor location ...

  2. The Degradation of Beam Quality in Large-Core Optical Fiber

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    The degradation of beam quality in large-core fiber is investigated experimentally. It is found that the output beam quality factor M2 is a compound tanh function of the fiber lengths and misalignment launch results that the beam quality degraded faster.

  3. Data acquisition and online monitoring software for CBM test beams

    International Nuclear Information System (INIS)

    The Compressed Baryonic Matter (CBM) experiment is intended to run at the FAIR facility that is currently being built at GSI in Darmstadt, Germany. For testing of future CBM detector and read-out electronics prototypes, several test beam campaigns have been performed at different locations, such as GSI, COSY, and CERN PS. The DAQ software has to treat various data inputs: standard VME modules on the MBS system, and different kinds of FPGA boards, read via USB, Ethernet, or optical links. The Data Acquisition Backbone Core framework (DABC) is able to combine such different data sources with event-builder processes running on regular Linux PCs. DABC can also retrieve the instrumental set-up data from EPICS slow control systems and insert it into the event data stream for later analysis. Vice versa, the DIM based DABC control protocol has been integrated to the general CBM EPICS IOC by means of an EPICS-DIM interface. Hence the DAQ can be monitored and steered with a CSS based operator GUI. The CBM online monitoring analysis is based on the GSI Go4 framework which can directly connect to DABC online data via sockets, or process stored data from list-mode files. A Go4 sub-framework has been implemented to provide possibility of parallel development of analysis code for different sub-detectors groups. This allows divide the Go4 components up into independent software packages that can run either standalone, or together at the beam-time in a full set-up.

  4. Quality Assurance Project Plan for Facility Effluent Monitoring Plan activities

    International Nuclear Information System (INIS)

    This Quality Assurance Project Plan addresses the quality assurance requirements for the Facility Monitoring Plans of the overall site-wide environmental monitoring plan. This plan specifically applies to the sampling and analysis activities and continuous monitoring performed for all Facility Effluent Monitoring Plan activities conducted by Westinghouse Hanford Company. It is generic in approach and will be implemented in conjunction with the specific requirements of individual Facility Effluent Monitoring Plans. This document is intended to be a basic road map to the Facility Effluent Monitoring Plan documents (i.e., the guidance document for preparing Facility Effluent Monitoring Plans, Facility Effluent Monitoring Plan determinations, management plan, and Facility Effluent Monitoring Plans). The implementing procedures, plans, and instructions are appropriate for the control of effluent monitoring plans requiring compliance with US Department of Energy, US Environmental Protection Agency, state, and local requirements. This Quality Assurance Project Plan contains a matrix of organizational responsibilities, procedural resources from facility or site manuals used in the Facility Effluent Monitoring Plans, and a list of the analytes of interest and analytical methods for each facility preparing a Facility Effluent Monitoring Plan. 44 refs., 1 figs., 2 tabs

  5. Thin silicon strip detectors for beam monitoring in Micro-beam Radiation Therapy

    International Nuclear Information System (INIS)

    Microbeam Radiation Therapy (MRT) is an emerging cancer treatment that is currently being developed at the European Synchrotron Radiation Facility (ESRF) in Grenoble, France. This technique uses a highly collimated and fractionated X-ray beam array with extremely high dose rate and very small divergence, to benefit from the dose-volume effect, thus sparing healthy tissue. In case of any beam anomalies and system malfunctions, special safety measures must be installed, such as an emergency safety shutter that requires continuous monitoring of the beam intensity profile. Within the 3DMiMic project, a novel silicon strip detector that can tackle the special features of MRT, such as the extremely high spatial resolution and dose rate, has been developed to be part of the safety shutter system. The first prototypes have been successfully fabricated, and experiments aimed to demonstrate their suitability for this unique application have been performed. Design, fabrication and the experimental results as well as any identified inadequacies for future optimisation are reported and discussed in this paper

  6. Thin silicon strip detectors for beam monitoring in Micro-beam Radiation Therapy

    Science.gov (United States)

    Povoli, M.; Alagoz, E.; Bravin, A.; Cornelius, I.; Bräuer-Krisch, E.; Fournier, P.; Hansen, T. E.; Kok, A.; Lerch, M.; Monakhov, E.; Morse, J.; Petasecca, M.; Requardt, H.; Rosenfeld, A. B.; Röhrich, D.; Sandaker, H.; Salomé, M.; Stugu, B.

    2015-11-01

    Microbeam Radiation Therapy (MRT) is an emerging cancer treatment that is currently being developed at the European Synchrotron Radiation Facility (ESRF) in Grenoble, France. This technique uses a highly collimated and fractionated X-ray beam array with extremely high dose rate and very small divergence, to benefit from the dose-volume effect, thus sparing healthy tissue. In case of any beam anomalies and system malfunctions, special safety measures must be installed, such as an emergency safety shutter that requires continuous monitoring of the beam intensity profile. Within the 3DMiMic project, a novel silicon strip detector that can tackle the special features of MRT, such as the extremely high spatial resolution and dose rate, has been developed to be part of the safety shutter system. The first prototypes have been successfully fabricated, and experiments aimed to demonstrate their suitability for this unique application have been performed. Design, fabrication and the experimental results as well as any identified inadequacies for future optimisation are reported and discussed in this paper.

  7. Reliability Tests of the LHC Beam Loss Monitoring FPGA Firmware

    CERN Document Server

    Hajdu, C F; Dehning, B; Jackson, S

    2010-01-01

    The LHC Beam Loss Monitoring (BLM) system is one of the most complex instrumentation systems deployed in the LHC. In addition to protecting the collider, the system also needs to provide a means of diagnosing machine faults and deliver a feedback of losses to the control room as well as to several systems for their setup and analysis. It has to transmit and process signals from almost 4’000 monitors, and has nearly 3 million configurable parameters. In a system of such complexity, firmware reliability is a critical issue. The integrity of the signal chain of the LHC BLM system and its ability to correctly detect unwanted scenarios and thus provide the required protection level must be ensured. In order to analyze the reliability and functionality, an advanced verification environment has been developed to evaluate the performance and response of the FPGA-based data analysis firmware. This paper will report on the numerous tests that have been performed and on how the results are used to quantify the reliabi...

  8. Measurements of the performance of a beam condition monitor prototype in a 5 GeV electron beam

    Science.gov (United States)

    Hempel, M.; Afanaciev, K.; Burtowy, P.; Dabrowski, A.; Henschel, H.; Idzik, M.; Karacheban, O.; Lange, W.; Leonard, J.; Levy, I.; Lohmann, W.; Pollak, B.; Przyborowski, D.; Ryjov, V.; Schuwalow, S.; Stickland, D.; Walsh, R.; Zagozdzinska, A.

    2016-08-01

    The Fast Beam Conditions Monitor, BCM1F, in the Compact Muon Solenoid, CMS, experiment was operated since 2008 and delivered invaluable information on the machine induced background in the inner part of the CMS detector supporting a safe operation of the inner tracker and high quality data. Due to the shortening of the time between two bunch crossings from 50 ns to 25 ns and higher expected luminosity at the Large Hadron Collider, LHC, in 2015, BCM1F needed an upgrade to higher bandwidth. In addition, BCM1F is used as an on-line luminometer operated independently of CMS. To match these requirements, the number of single crystal diamond sensors was enhanced from 8 to 24. Each sensor is subdivided into two pads, leading to 48 readout channels. Dedicated fast front-end ASICs were developed in 130 nm technology, and the back-end electronics is completely upgraded. An assembled prototype BCM1F detector comprising sensors, a fast front-end ASIC and optical analog readout was studied in a 5 GeV electron beam at the DESY-II accelerator. Results on the performance are given.

  9. A two-dimensional beam profile monitor with high dynamic-range using multi-screen for intense proton beams

    International Nuclear Information System (INIS)

    An instrument for beam shape measurement including the halo is strongly required in intense proton accelerators such as the J-PARC. For diagnosing of the beam halo and halo cut at the injection beam line (3-50 BT) which connects the rapid cycling synchrotron (RCS) and the main ring (MR) in the J-PARC, we have developed a high sensitive two-dimensional profile monitor with screens. The beam core was observed with OTR from titanium foil screen, and the beam halo whose density were less almost three orders than it of the beam core was observed with fluorescence (FL) from chromium doped alumina screens placed in the four directions around the beam space. These alumina screens and remote movable system were installed in this spring, and they can be used with existing OTR screens simultaneously. These OTR and FL are focused in the same optical system having large opening angle of 30 degree, and these are observed by a camera with an image intensifier (II). By these method, two-dimensional beam profile contained the beam halo of high-intensity proton beam of 1.5 × 1013 was measured successfully with a dynamic range of more than six orders in magnitude. Two typical measured results as below are discussed mainly in this paper: (1) halo cut by the beam collimators, (2) simultaneous measurement of the beam halo of the minus 4th order with the beam core. These high-sensitive two-dimensional data give powerful information for beam diagnosing. As further topics, increasing the sensitivity of the beam halo measurement and simultaneous measurement of beam halo with beam core with wider dynamic range, their studies are planned this autumn, are also described. (author)

  10. Representativeness of air quality monitoring networks

    NARCIS (Netherlands)

    Duyzer, J.; Hout, D. van den; Zandveld, P.; Ratingen, S. van

    2015-01-01

    The suitability of European networks to check compliance with air quality standards and to assess exposure of the population was investigated. An air quality model (URBIS) was applied to estimate and compare the spatial distribution of the concentration of nitrogen dioxide (NO2) in ambient air in fo

  11. Development of a highly sensitive beam current monitor with a SQUID and superconducting magnetic shield

    International Nuclear Information System (INIS)

    Beam diagnostics are an essential constituent of any accelerator. There are a large variety of beam parameters, and total current is one of the most important parameters for accelerators. A current monitor is used to operate an accelerator efficiently and to improve the performance of the machine. A Faraday cup is the most fundamental current detection process, in which charged particles are stopped in the cup. However, this destructive method cannot be applied for high-current or high-energy beams because the total energy carried by the beam can destroy and activate the intercepting material. Therefore, non-destructive beam current measurement requires the use of current transformers that detect the magnetic field produced by the pulsed or DC beam. On the other hand, a new type of beam current monitor using a low-temperature superconducting (LTS) magnetic shield and an LTS SQUID was developed to measure the faint ion beams that are below the lowest measurable limit of the DC current transformer (DCCT) for atomic-physics studies. Recently, a prototype of a highly sensitive SQUID current monitor for measuring the intensity of faint beams, such as radioisotope beams, was completed for the RIKEN RI beam factory. This monitor is composed of a high-temperature superconducting (HTS) magnetic shield and an HTS SQUID. The first measurements using ion beams were carried out in the CNS experimental hall and RIKEN Ring Cyclotron (RRC). This paper first describes the principle of the conventional current monitor such as the Faraday cup and current transformers. Second, the progress of the LTS SQUID current monitor is discussed, and finally, the present status of the prototype of the LTS SQUID current monitor is discussed, and finally, the present status of the prototype of the HTS SQUID current monitor at RIKEN and the results of the first beam measurement are given. (author)

  12. La Parguera, Puerto Rico Water Quality Monitoring Data 2003 - Present

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These water quality data are one of many studies being done to assess and monitor coral reef ecosystems. The intent of this work is three fold: (1) to spatially...

  13. Monitoring of Indoor Air Quality in Libraries and Archives

    Czech Academy of Sciences Publication Activity Database

    Kouřil, M.; Ďurovič, M.; Straka, R.; Smolík, Jiří; Mašková, Ludmila

    Prague: -, 2014, s. 32. ISBN N. [International Conference Indoor Air Quality in Heritage and Historic Environments /11./. Prague (CZ), 13.04.2014-16.04.2014] Institutional support: RVO:67985858 Keywords : corrosion * classification * monitoring Subject RIV: CF - Physical ; Theoretical Chemistry

  14. St. John, USVI Water Quality Monitoring Data 2003 - Present

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These water quality data are one of many studies being done to assess and monitor coral reef ecosystems. The intent of this work is three fold: (1) to spatially...

  15. DANIDA; Air Quality Monitoring Programme. Mission 2 Report

    Energy Technology Data Exchange (ETDEWEB)

    Sivertsen, B.

    1996-06-01

    The report deals with the EIMP (Environmental Information and Monitoring Programme for the Arab Republic of Egypt). The programme is funded by Danida which is a cooperation project between Norway and Denmark. The programme covers the monitoring of air pollution, coastal water monitoring, and the monitoring of pollution sources and emissions. This report pays the attention to the Norwegian part of the programme executed by NILU (Norwegian Institute for Air Research) which covers the development air quality monitoring network. 14 refs., 51 figs., 18 tabs.

  16. A Scintillating-fiber Beam Profile Monitor for the DAFNE BTF

    CERN Document Server

    Anelli, M; Mazzitelli, G; Valente, P

    2004-01-01

    A scintillating-fiber beam profile detector has been designed, built and tested, for the monitoring of the position and size of the electron beam of the DAFNE, the recently commissioned electron beam-test facility at the Frascati LNF. A description of the detector construction and assembly, together with the results achieved during the 2003-2004 run, are here reported.

  17. Beam halo monitoring at J-PARC 3-50 beam transport line using long air ionization chamber

    International Nuclear Information System (INIS)

    3 long-type Air Ionization Chambers (AICs) have been installed along 350BT which is the beam transport from the 3GeV Rapid Cycling Synchrotron (RCS) to the Main Ring synchrotron (MR) to monitor beam losses. 3-50BT collimators are used to remove beam halo components outside the emittance larger than 54[πmm · mrad] for horizontal and 60[πmm · mrad] for vertical plane, at present operations. By measuring the beam loss induced radiations from the 3-50BT collimators, the beam halo components have been monitoring on line. Details of the system, calibration results, and resolution of the system will be described in this paper. (author)

  18. Cryogenic Beam Loss Monitors for the Superconducting Magnets of the LHC

    CERN Document Server

    Bartosik, MR; Sapinski, M; Kurfuerst, C; Griesmayer, E; Eremin, V; Verbitskaya, E

    2014-01-01

    The Beam Loss Monitor detectors close to the interaction points of the Large Hadron Collider are currently located outside the cryostat, far from the superconducting coils of the magnets. In addition to their sensitivity to lost beam particles, they also detect particles coming from the experimental collisions, which do not contribute significantly to the heat deposition in the superconducting coils. In the future, with beams of higher energy and brightness resulting in higher luminosity, distinguishing between these interaction products and dangerous quench-provoking beam losses from the primary proton beams will be challenging. The system can be optimised by locating beam loss monitors as close as possible to the superconducting coils, inside the cold mass in a superfluid helium environment, at 1.9 K. The dose then measured by such Cryogenic Beam Loss Monitors would more precisely correspond to the real dose deposited in the coil. The candidates under investigation for such detectors are based on p+-n-n+ si...

  19. Monitoring activities in the Dutch National Air Quality Monitoring Network in 2000 and 2001

    OpenAIRE

    Elzakker BG van; LLO

    2001-01-01

    The Dutch National Air Quality Monitoring Network (LML in Dutch) is one of the responsibilities of the Air Research Laboratory of the National Institute of Public Health and the Environment. The main objectives of the LML are to monitor ambient air quality, facilitate implementation of air quality standards, alert authorities and the public to pollution episodes, support validation of model results, support diagnosis using model simulation, support short-term model prognosis and assist in qua...

  20. An Expert System Applied in Construction Water Quality Monitoring

    OpenAIRE

    Leila Ooshaksaraie; Noor E.A. Basri

    2011-01-01

    Problem statement: An untoward environmental impact of urban growth in Malaysia has been deterioration in a number of watercourses due to severe siltation and other pollutants from the construction site. Water quality monitoring is a plan for decision makers to take into account the adverse impacts of construction activities on the receiving water bodies. It is also a process for collecting the construction water quality monitoring, baseline data and standard level. Approa...

  1. Using statistical quality control techniques to monitor blood glucose levels.

    OpenAIRE

    Oniki, T. A.; Clemmer, T. P.; Arthur, L. K.; Linford, L. H.

    1995-01-01

    Continuous Quality Improvement techniques developed in industry are increasingly being applied to the medical field. Statistical process control charts are a CQI technique aimed at monitoring a process and its variability. At our hospital, statistical quality control charts are being constructed from laboratory blood glucose measurements of patients receiving enteral or parenteral nutrition. The charts will be used to monitor glucose levels, reveal variations, and illustrate the effects of ne...

  2. A new method for improving beam quality of LINAC

    International Nuclear Information System (INIS)

    The principle of the self-adaptive feed-forward (SAFF) control to improve the beam quality of linac is introduced. the analytical procedure for calculating the control signals, the structure of a practical control system, and applications of SAFF in klystron, RF gun, and linac are presented, especially the application in the thermionic gun whose response is non-linear, time-variant and of large time-delay. The described control system is operational and some primary experimental results have been obtained, including the control of amplitude and phase fluctuations of the klystron output, the microwave field in the gun cavity and linac

  3. DANIDA; Air Quality Monitoring Programme. Mission 3 Report

    Energy Technology Data Exchange (ETDEWEB)

    Sivertsen, B.; Marsteen, L.

    1996-12-31

    In the development of the Environmental Information and Monitoring Programme for the Arab Republic of Egypt (EIMP), NILU is responsible for the establishment of an air pollution monitoring system. This report summarizes the third mission to Egypt and includes meetings and site visit reports. Air quality sites in Alexandria are described and comments are given to earlier selected sites in Cairo

  4. 77 FR 8160 - Quality Assurance Requirements for Continuous Opacity Monitoring Systems at Stationary Sources

    Science.gov (United States)

    2012-02-14

    ...--Quality Assurance Requirements for Continuous Opacity Monitoring Systems at Stationary Sources Docket, EPA... entities. This action establishes quality assurance procedures for continuous opacity monitoring systems... action simply establishes quality assurance procedures for continuous opacity monitoring systems used...

  5. Entropy-Based Assessment of Water Quality Monitoring Networks

    OpenAIRE

    ÖZKUL, Sevinç

    2001-01-01

    Assessment of water quality monitoring networks requires potential methods to delineate the efficiency and cost-effectiveness of current monitoring programs. To this end, the concept of entropy has been considered as a promising method in previous studies as it quantitatively measures the information produced by a network. This paper introduces a new approach for the assessment of combined spatial/temporal frequencies of monitoring networks. The results are demonstrated in the case ...

  6. Operational Experience with Beam Alignment and Monitoring Using Non-Destructive Beam Position Monitors in the Cyclotron Beamlines at iThemba LABS

    CERN Document Server

    Conradie, J L; Delsink, J L G; Fourie, D T; Kormany, Z; Mansfield, P T; Rohwer, P F; Sakildien, M

    2005-01-01

    At iThemba LABS proton beams, accelerated in a K=200 separated-sector cyclotron with a K=8 solid-pole injector cyclotron, are utilized for the production of radioisotopes and particle radiotherapy. Beams of heavy ions and polarized protons, pre-accelerated in a second injector cyclotron, are available for nuclear physics research. Beam position monitors have been developed for non-destructive alignment and continuous display of the beam position in the beam lines for the more intense beams used for therapy and the production of radioisotopes in cooperation* with Forschungszentrum Jülich. The monitors consist of four-section strip lines. Narrow-band super-heterodyne RF electronic equipment with automatic frequency and gain control measures the signals at the selected harmonic. A control module sequentially processes the signals and delivers calculated horizontal and vertical beam position data via a serial network to the computer control system. Eleven monitors have been installed in the transfer beam line be...

  7. LHC Collimators with Embedded Beam Position Monitors: a New Adbanced Mechanical Design

    CERN Document Server

    Dallocchio, A; Boccard, C; Carra, F; Gasior, M; Gentini, L; Timmins, M

    2011-01-01

    The LHC collimation system, ensuring both functions of beam cleaning and machine protection, is potentially submitted to high-energy beam impacts. Currently the collimators setup is performed by monitoring beam losses generated by the collimator jaws when approaching the particle beam. This procedure is applied to all LHC collimators (almost one hundred), taking several hours, and needs to be repeated if beam settings change significantly. Furthermore, during the beam-based alignment, the LHC tertiary collimators are potentially exposed to abnormal losses entailing possible damage to their tungsten jaws. To improve the efficiency of the machine operation and better control the particle beam a new advanced design embedding Beam Position Monitors (BPM) into the movable collimator jaws has been developed. This paper describes the mechanical design of various types of future collimators with embedded BPMs. Experimental measurements performed on a simplified functional prototype installed in the CERN SPS showed th...

  8. Commissioning and performance of the beam monitor system for XFEL/SPring-8 'SACLA'

    International Nuclear Information System (INIS)

    The beam monitor system for the XFEL facility 'SACLA' is demanded to measure a beam position with sub-μm resolution, a beam profile with few-μm resolution, a temporal structure with 10 fs resolution. Therefore, we developed and constructed the beam monitor system consisting of rf cavity beam position monitors (RF-BPM), screen monitors (SCM) with OTR targets and YAG:Ce scintillators, high-speed differential current transformers (CT), an rf deflector system (RFDEF), a streak camera and coherent synchrotron radiation (CSR) monitors. After the commissioning of the beam monitor system, the position resolution of the RF-BPM was found to be less than 0.6 μm (RMS) and the temporal resolution of the RFDEF was approximately 10 fs. Although SCMs observed anomalous radiation due to coherent OTR (COTR), COTR was diminished by a YAG:Ce target with an OTR mask. As a result of the beam tuning with the beam monitor system, SACLA succeeded the lasing with a wavelength of 0.12 nm. (author)

  9. Quality control and patient dosimetry in dental cone beam CT

    International Nuclear Information System (INIS)

    This paper presents the initial experience in performing quality control and patient dose measurements in a cone beam computed tomography (CT) scanner (ILUMATM Ultra, IMTEC Imaging, USA) for oral and maxillofacial radiology. The X-ray tube and the generator were tested first, including the kVp accuracy and precision, and the half-value layer (HVL). The following tests specific for panoramic dental systems were also performed: tube output, beam size and beam alignment to the detector. The tests specific for CT included measurements of noise and CT numbers in water and in air, as well as the homogeneity of CT numbers. The most appropriate dose quantity was found to be the air kerma-area product (KAP) measured with a KAP-metre installed at the tube exit. KAP values were found to vary from 110 to 185 μGy m2 for available adult protocols and to be 54 μGy m2 for the paediatric protocol. The effective dose calculated with the software PCXMC (STUK (Finland)) was 0.05 mSv for children and 0.09-0.16 mSv for adults. (authors)

  10. Optimization of In-Beam Positron Emission Tomography for Monitoring Heavy Ion Tumor Therapy

    OpenAIRE

    Vieira Crespo, Paulo Alexandre

    2010-01-01

    In-beam positron emission tomography (in-beam PET) is currently the only method for an in-situ monitoring of highly tumor-conformed charged hadron therapy. In such therapy, the clinical effect of deviations from treatment planning is highly minimized by implementing safety margins around the tumor and selecting proper beam portals. Nevertheless, in-beam PET is able to detect eventual, undesirable range deviations and anatomical modifications during fractionated irradiation, to verify the accu...

  11. Quality Assurance Program Plan for radionuclide airborne emissions monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Vance, L.M.

    1993-07-01

    This Quality Assurance Program Plan (QAPP) describes the quality assurance requirements and responsibilities for radioactive airborne emissions measurements activities from regulated stacks are controlled at the Hanford Site. Detailed monitoring requirements apply to stacks exceeding 1% of the standard of 10 mrem annual effective dose equivalent to the maximally exposed individual from operations of the Hanford Site.

  12. Quality Assurance Program Plan for radionuclide airborne emissions monitoring

    International Nuclear Information System (INIS)

    This Quality Assurance Program Plan (QAPP) describes the quality assurance requirements and responsibilities for radioactive airborne emissions measurements activities from regulated stacks are controlled at the Hanford Site. Detailed monitoring requirements apply to stacks exceeding 1% of the standard of 10 mrem annual effective dose equivalent to the maximally exposed individual from operations of the Hanford Site

  13. Numerical analysis of the beam quality and spectrum of wavelength-beam-combined laser diode arrays

    Science.gov (United States)

    Tang, Xuan; Wang, Xiao-Jun; Ke, Wei-Wei

    2015-02-01

    In this paper, a numerical model is presented to simulation the performance of the wavelength-beam-combined laser diode arrays (LDA) system. The eigen mode expansion method is used to describe the two-dimensional optical amplification and the strength of field feedback of external cavity. To describe the mode competition in laser diodes, the gain saturation effect is considered. The two-dimension distributions of the carrier concentration, recombination rates, and optical gain are calculated for solving the laser dynamic equation. The Fresnel integration, grating equation and mode overlap integration are used to obtain the feedback coefficient of extent cavity diffraction. Quantum noise is considered to evaluate the spectral linewidth of semiconductor laser. Based on the numerical model, the impact of the mutual optical feedback on the beam quality and spectrum of the LDA is present and analysis.

  14. Digital Beam Position Monitor for the Happex Experiment

    International Nuclear Information System (INIS)

    The proposed HAPPEX experiment at CEBAF employs a three cavity monitor system for high-precision (1 mm), high-bandwidth (100 kHz) position measurements. This is performed using a cavity triplet consisting of two TM110-mode cavities (one each for X and Y planes) combined with a conventional TM-010-mode cavity for a phase and magnitude reference. Traditional systems have used the TM010 cavity output to directly down convert the BPM cavity signals to base band. The Multi-channel HAPPEX digital receiver simultaneously I/Q samples each cavity and extracts position using a CORDIC algorithm. The hardware design consists of a digital receiver daughter board and digital processor motherboard that resides in a VXI crate. The daughter board down converts 1.497 GHz signals from the TM010 cavity and X and Y signals from the TM110 cavities to 4 MHz, and extracts the quadrature digital signals. The motherboard processes this data and computes beam intensity and X-Y positions with a resolution of one mm, 100 kHz output bandwidth, and overall latency of ten microseconds. The results are available in both analog and digital format

  15. Digital beam position monitor for the HAPPEX experiment

    International Nuclear Information System (INIS)

    The proposed HAPPEX experiment at CEBAF employs a three cavity monitor system for high precision (1um), high bandwidth (100 kHz) position measurements. This is performed using a cavity triplet consisting of two TM110-mode cavities (one each for X and Y planes) combined with a conventional TM010-mode cavity for a phase and magnitude reference. Traditional systems have used the TM010 cavity output to directly down convert the BPM cavity signals to base band. The multi-channel HAPPEX digital receiver simultaneously I/Q samples each cavity and extracts position using a CORDIC algorithm. The hardware design consists of a RF receiver daughter board and a digital processor motherboard that resides in a VXI crate. The daughter board down converts 1.497 GHz signals from the TM010 cavity and X and Y signals from the TM110 cavities to 3 MHz and extracts the quadrature digital signals. The motherboard processes this data and computes beam intensity and X-Y positions with resolution of 1um, 100 kHz output bandwidth, and overall latency of 1us. The results are available in both the analog and digital format

  16. Monitoring the extracted proton beam at the SPS

    CERN Multimedia

    1977-01-01

    Fluorescent screens in front of the target positions allow a precise adjustement in front of them. A similar photo was recorded at the beam dump at the beam injection into the SPS, see Weekly Bulletin of April 1976.

  17. Quality control and quality assurance in individual monitoring of ionising radiations

    International Nuclear Information System (INIS)

    This paper describes the programmes and approaches that are to be considered in developing and introducing quality assurance and quality control procedures in individual monitoring services. Quality assurance and quality control in individual monitoring services are essential to maintain quality and are of increasing importance in order to meet the requirements of national regulations and international standards and guidelines. It is recommended here that all organisations offering individual monitoring services should run their services based on the principles of Quality System as given in the European Standard EN45001 and maintain a property resources QA/QC programme as an integral part of their operations. All aspects of QA/QC in individual monitoring services starting from the initial selection, installation, calibration, and operation to the final products including dose reporting, dose record keeping, dealing with customers' complaints and product liability issues have been discussed. (Author)

  18. Automated Method for Monitoring Water Quality Using Landsat Imagery

    Directory of Open Access Journals (Sweden)

    D. Clay Barrett

    2016-06-01

    Full Text Available Regular monitoring of water quality is increasingly necessary to keep pace with rapid environmental change and protect human health and well-being. Remote sensing has been suggested as a potential solution for monitoring certain water quality parameters without the need for in situ sampling, but universal methods and tools are lacking. While many studies have developed predictive relationships between remotely sensed surface reflectance and water parameters, these relationships are often unique to a particular geographic region and have little applicability in other areas. In order to remotely monitor water quality, these relationships must be developed on a region by region basis. This paper presents an automated method for processing remotely sensed images from Landsat Thematic Mapper (TM and Enhanced Thematic Mapper Plus (ETM+ and extracting corrected reflectance measurements around known sample locations to allow rapid development of predictive water quality relationships to improve remote monitoring. Using open Python scripting, this study (1 provides an openly accessible and simple method for processing publicly available remote sensing data; and (2 allows determination of relationships between sampled water quality parameters and reflectance values to ultimately allow predictive monitoring. The method is demonstrated through a case study of the Ozark/Ouchita-Appalachian ecoregion in eastern Oklahoma using data collected for the Beneficial Use Monitoring Program (BUMP.

  19. No Reference Video-Quality-Assessment Model for Monitoring Video Quality of IPTV Services

    Science.gov (United States)

    Yamagishi, Kazuhisa; Okamoto, Jun; Hayashi, Takanori; Takahashi, Akira

    Service providers should monitor the quality of experience of a communication service in real time to confirm its status. To do this, we previously proposed a packet-layer model that can be used for monitoring the average video quality of typical Internet protocol television content using parameters derived from transmitted packet headers. However, it is difficult to monitor the video quality per user using the average video quality because video quality depends on the video content. To accurately monitor the video quality per user, a model that can be used for estimating the video quality per video content rather than the average video quality should be developed. Therefore, to take into account the impact of video content on video quality, we propose a model that calculates the difference in video quality between the video quality of the estimation-target video and the average video quality estimated using a packet-layer model. We first conducted extensive subjective quality assessments for different codecs and video sequences. We then model their characteristics based on parameters related to compression and packet loss. Finally, we verify the performance of the proposed model by applying it to unknown data sets different from the training data sets used for developing the model.

  20. Monitoring and improving quality of colonoscopy

    NARCIS (Netherlands)

    S.C. van Doorn

    2015-01-01

    Colorectal cancer (CRC) is one of the most commonly diagnosed cancers in the western world. High quality colonoscopy has the potential to reduce CRC mortality by detecting carcinomas in early stages and reduce its incidence by detecting and removing its main precursor lesions, adenomas. Variability

  1. CMS Tracker Integration: monitoring the process quality

    International Nuclear Information System (INIS)

    The CMS experiment at LHC features the largest Silicon Strip Tracker (SST) ever built. This detector is composed of about 15000 modules, thus the potential problems of the system comes from its complexity. This article covers the tests performed during the tracker integration, describing their motivations in terms of process quality assurance

  2. Near-Facility Environmental Monitoring Quality Assurance Project Plan

    International Nuclear Information System (INIS)

    This Quality Assurance Project Plan addresses the quality assurance requirements for the activities associated with the preoperational and near-facility environmental monitoring directed by Waste Management Technical Services and supersedes HNF-EP-0538-4. This plan applies to all sampling and monitoring activities performed by Waste Management Technical Services in implementing near-facility environmental monitoring at the Hanford Site. This Quality Assurance Project Plan is required by U.S. Department of Energy Order 5400.1 (DOE 1990) as a part of the Environmental Monitoring Plan (DOE-RL 1997) and is used to define: Environmental measurement and sampling locations used to monitor environmental contaminants near active and inactive facilities and waste storage and disposal sites; Procedures and equipment needed to perform the measurement and sampling; Frequency and analyses required for each measurement and sampling location; Minimum detection level and accuracy; Quality assurance components; and Investigation levels. Near-facility environmental monitoring for the Hanford Site is conducted in accordance with the requirements of U.S. Department of Energy Orders 5400.1 (DOE 1990), 5400.5 (DOE 1993), 5484.1 (DOE 1990), and 435.1 (DOE 1999), and DOE/EH-O173T (DOE 1991). It is Waste Management Technical Services' objective to manage and conduct near-facility environmental monitoring activities at the Hanford Site in a cost-effective and environmentally responsible manner that is in compliance with the letter and spirit of these regulations and other environmental regulations, statutes, and standards

  3. Process monitoring using a Quality and Technical Surveillance Program

    Energy Technology Data Exchange (ETDEWEB)

    Rafferty, C.A.

    1995-02-01

    The purpose of process monitoring using a Quality and Technical Surveillance Program was to help ensure manufactured clad vents sets fully met technical and quality requirements established by the manufacturer and the customer, and that line and program management were immediately alerted if any aspect of the manufacturing activities drifted out of acceptable limits. The Quality and Technical Surveillance Program provided a planned, scheduled approach to monitor key processes and documentation illuminated potential problem areas early enough to permit timely corrective actions to reverse negative trends that, if left uncorrected, could have resulted in deficient hardware. Significant schedule and cost impacts were eliminated.

  4. Process monitoring using a Quality and Technical Surveillance Program

    International Nuclear Information System (INIS)

    The purpose of process monitoring using a Quality and Technical Surveillance Program was to help ensure manufactured clad vents sets fully met technical and quality requirements established by the manufacturer and the customer, and that line and program management were immediately alerted if any aspect of the manufacturing activities drifted out of acceptable limits. The Quality and Technical Surveillance Program provided a planned, scheduled approach to monitor key processes and documentation illuminated potential problem areas early enough to permit timely corrective actions to reverse negative trends that, if left uncorrected, could have resulted in deficient hardware. Significant schedule and cost impacts were eliminated

  5. Performance evaluation of quality monitor models in spot welding

    Institute of Scientific and Technical Information of China (English)

    Zhang Zhongdian; Li Dongqing; Wang Kai

    2005-01-01

    Performance of quality monitor models in spot welding determines the monitor precision directly, so it's crucial to evaluate it. Previously, mean square error ( MSE ) is often used to evaluate performances of models, but it can only show the total errors of finite specimens of models, and cannot show whether the quality information inferred from models are accurate and reliable enough or not. For this reason, by means of measure error theory, a new way to evaluate the performances of models according to the error distributions is developed as follows: Only if correct and precise enough the error distribution of model is, the quality information inferred from model is accurate and reliable.

  6. The CMS Data Quality Monitoring software experience and future improvements

    CERN Document Server

    De Guio, Federico

    2013-01-01

    The Data Quality Monitoring (DQM) Software proved to be a central tool in the CMS experiment. Its flexibility allowed its integration in several environments Online, for real-time detector monitoring; Offline, for the final, fine-grained Data Certification; Release Validation, to constantly validate the functionality and the performance of the reconstruction software; in Monte Carlo productions. The central tool to deliver Data Quality information is a web site for browsing data quality histograms (DQM GUI). In this contribution the usage of the DQM Software in the different environments and its integration in the CMS Reconstruction Software Framework and in all production workflows are presented.

  7. Monitoring gas quality green gas feeding in; Monitoring gaskwaliteit groengasinvoeding

    Energy Technology Data Exchange (ETDEWEB)

    Holstein, J. [DNV KEMA Energy and Sustainability, Arnhem (Netherlands); Polman, E. [Kiwa Technology, Apeldoorn (Netherlands)

    2013-04-15

    Due to the growing number of green gas facilities in the Netherlands more practical knowledge is collected about the production and injection of green gas. Also there was the need to gather data about more practical experiences and knowledge about the gas quality, the performance of gas cleaning and gas treatment systems, as well the integration of green gas in the gas infrastructure. In addition to this, there is a need to get insight in the safety aspects of green gas injection. In order to comply this demand, DNV KEMA en Kiwa Technology measured the quality parameters continuously between June 2012 en January 2013 (three weeks) and discontinuously (gas samples) of green gas at eight production facilities. The measurements have been performed at designated places and are independent from the measurements of the biomethane producer. In order to be sure that the results of DNV KEMA and Kiwa are comparable, a combined measurement program was executed. It results in uniformity for all the measured values: the differences are within the uncertainty level for each component. During the measurement period of three weeks, the gas quality parameters were compared to specifications, written down in the national regulations for the transport and the distribution grid respectively [Dutch] Door het groeiend aantal groengasinvoedingen in Nederland wordt steeds meer praktijkkennis verzameld. Er dient meer praktijkkennis te worden verzameld over de chemische gaskwaliteit, prestaties van de gasreiniging- en gasopwaardering en de wijze van inpassing in de bestaande infrastructuur. Daarnaast is het wenselijk om inzicht te verkrijgen in de veiligheid van groengasinvoeding. Daarop is de groengaskwaliteit op acht locaties over een periode van drie weken continu en discontinu gemeten tussen juni 2012 en januari 2013. De metingen zijn uitgevoerd op een aangewezen plaats door de netbeheerder en staan los van de metingen van de invoeders zelf. Voor het waarborgen van de uniformiteit van

  8. Quality assurance of ultrasound imaging instruments by monitoring the monitor.

    Science.gov (United States)

    Walker, J B; Thorne, G C; Halliwell, M

    1993-11-01

    Ultrasound quality assurance (QA) is a means of assuring the constant performance of an ultrasound instrument. A novel 'ultrasound image analyser' has been developed to allow objective, accurate and repeatable measurement of the image displayed on the ultrasound screen, i.e. as seen by the operator. The analyser uses a television camera/framestore combination to digitize and analyse this image. A QA scheme is described along with the procedures necessary to obtain a repeatable measurement of the image so that comparisons with earlier good images can be made. These include repositioning the camera and resetting the video display characteristics. The advantages of using the analyser over other methods are discussed. It is concluded that the analyser has distinct advantages over subjective image assessment methods and will be a valuable addition to current ultrasound QA programmes. PMID:8272435

  9. External beam monitoring of the Cyclone 30 cyclotron of IPEN-CNEN-SP

    International Nuclear Information System (INIS)

    Due to the increasing demand for cyclotron radioisotopes and the high cost of equipment and materials involved in the process, it becomes evident the importance of external beam monitoring of the cyclotron. In this way, the beam of the Cyclone 30 cyclotron of IPEN-CNEN/S P was characterized throughout the evaluation of its current intensity, profile (position, focus and geometry), alignment and homogeneity, by measuring currents, temperatures and pressures of irradiation systems. For this purpose, techniques and conventional devices, thermocouples and pressure sensors associated to electronic of instrumentation, and technology and flexibility of micro controllers allowed observing the beam behavior during irradiations in real time. The ion beam energy was also evaluated using activation analysis technique of monitor reactions in natCu. The beam monitoring systems have been contributing to prevent material damages and they have already been used in routine irradiations, bringing important advantages in the process of beam optimization of the Cyclone 30. (author)

  10. The new Beam Halo Monitor for the CMS experiment at the LHC

    CERN Document Server

    Tosi, Nicolo

    In the context of increasing beam energy and luminosity of the LHC accelerator at CERN, it will be important to accurately measure the Machine Induced Background. A new monitoring system will be installed in the CMS cavern for measuring the beam background at high radius. This detector, called the Beam Halo Monitor, will provide an online, bunch-by-bunch measurement of background induced by beam halo interactions, separately for each beam. The detector is composed of synthetic quartz Cherenkov radiators, coupled to fast UV sensitive photomultiplier tubes. The directional and fast response of the system allows the discrimination of the background particles from the dominant flux in the cavern induced by pp collision debris, produced within the 25 ns bunch spacing. The readout electronics of this detector will make use of many components developed for the upgrade of the CMS Hadron Calorimeter electronics, with a dedicated firmware and readout adapted to the beam monitoring requirements. The PMT signal will be d...

  11. Design alternatives for beam halo monitors in high intensity accelerators

    CERN Document Server

    Braun, H; Corsini, R; Lefèvre, T; Schulte, Daniel; Tecker, F A; Welsch, C P

    2005-01-01

    In future high intensity, high energy accelerators it must be ensured that particle losses are minimized as activation of the vacuum chambers or other components makes maintenance and upgrade work time consuming and costly. It is imperative to have a clear understanding of the mechanisms that can lead to halo formation and to have the possibility to test available theoretical models with an adequate experimental setup. Optical transition radiation (OTR) provides an interesting opportunity for linear real-time measurements of the transverse beam profile with a resolution which has been so far at best in the some μm range. However, the dynamic range of standard OTR systems is typically limited and needs to be improved for its application for halo measurements. In this contribution, the existing OTR system as it is installed in the CLIC test facility (CTF3) is analyzed and the contribution of each component to the final image quality discussed. Finally, possible halo measurement techniques based on OTR are pres...

  12. Quality monitoring in colonoscopy: Time to act

    Institute of Scientific and Technical Information of China (English)

    Mary A Atia; Francisco C Ramirez; Suryakanth R Gurudu

    2015-01-01

    Colonoscopy is the gold standard test for colorectalcancer screening. The primary advantage of colonoscopyas opposed to other screening modalities is the abilityto provide therapy by removal of precancerous lesionsat the time of detection. However, colonoscopy maymiss clinically important neoplastic polyps. The value ofcolonoscopy in reducing incidence of colorectal canceris dependent on many factors including, the patient,provider, and facility level. A high quality examinationincludes adequate bowel preparation, optimal colonoscopytechnique, meticulous inspection duringwithdrawal, identification of subtle flat lesions, andcomplete polypectomy. Considerable variation amonginstitutions and endoscopists has been reported in theliterature. In attempt to diminish this disparity, variousapproaches have been advocated to improve the qualityof colonoscopy. The overall impact of these interventionsis not yet well defined. Implementing optimal educationand training and subsequently analyzing the impactof these endeavors in improvement of quality will beessential to augment the utility of colonoscopy for theprevention of colorectal cancer.

  13. Air Quality Monitoring Using CCD/ CMOS Devices

    OpenAIRE

    Low, Khee Lam; Joanna, Tan Choay Ee; Sim, Keat; Jafri, Mohd Zubir Mat; and, Khiruddin Abdullah

    2010-01-01

    In this chapter, we showed a method for measuring of the air quality index by using the CCD/CMOS sensor. We showed two examples to obtain index values by using webcam and CCTV. Both devices provided a high correlation between the measured and estimated PM10. So, the imaging method is capable to measure PM10 values in the environment. Futher application can be conducted using different devices.

  14. Quality control of environmental radiation monitoring process

    International Nuclear Information System (INIS)

    This report summarizes for the period (January/2003 to September 2003) the analytical results of the Environmental Monitoring Program- Centro de Desenvolvimento da Tecnologia Nuclear - CDTN. A statistical treatment using control graphs for periodicity and tendency analysis according to temporal variation is also carried out. Moreover, a comparison of radioactive and stable elements concentrations with the derived and intake limits for ingestion and inhalation recommended by Comissao Nacional de Energia Nuclear, Fundacao Estatual do Meio Ambiente (FEAM) e Instituto Brasileiro do Meio Ambiente (IBAMA) is performed. The results are compliant with those recommended by the legislation. (author)

  15. Research on Monitoring Area Division of Quality Grade Changes in County Cultivated Land and Technology of Deploying Monitoring Point

    OpenAIRE

    Wei, Wei; Liao, Lijun; Yu, Jianxin

    2013-01-01

    It is an important means in management of improving both the quality and quantity of cultivated land to monitor grade changes in cultivated land quality. How to deploy monitoring network system and its point reasonably and roundly are the key to the technology of monitoring grade changes in cultivated land quality by monitoring grade changes in cultivated land quality dynamically in order to obtain the information to the index of cultivated land quality and its changes based on the existing a...

  16. Performance Studies of the Vibration Wire Monitor on the Test Stand with Low Energy Electron Beam

    Science.gov (United States)

    Okabe, Kota; Yoshimoto, Masahiro; Kinsho, Michikazu

    In the high intensity proton accelerator as the Japan Proton Accelerator Research Complex (J-PARC) accelerators, serious radiation and residual dose is induced by a small beam loss such a beam halo. Therefore, diagnostics of the beam halo formation is one of the most important issues to control the beam loss. For the beam halo monitor, the vibration wire monitor (VWM) has a potential for investigating the beam halo and weak beam scanning. The VWM has a wide dynamic range, high resolution and the VWM is not susceptible to secondary electrons and electric noises. We have studied the VWM features as a new beam-halo monitor on the test stand with low energy electron gun. The frequency shift of the irradiated vibration wire was confirmed about wire material and the electron beam profile measured by using the VWM was consistent with the results of the Faraday cup measurement. Also we calculated a temperature distribution on the vibration wire which is irradiated by the electron beam with the numerical simulation. The simulations have been fairly successful in reproducing the transient of the irradiated vibration wire frequency measured by test stand experiments. In this paper, we will report a result of performance evaluation for the VWM on the test stands and discuss the VWM for beam halo diagnostic

  17. Implementation of quality standards in an individual monitoring service

    International Nuclear Information System (INIS)

    In this paper the implementation of a quality system to the procedures of an individual monitoring service (IMS) is described from the practical perspective. The IMS of the Radiation and Nuclear Safety Authority (STUK) is used as an example. The IMS of STUK monitors about 8500 persons mainly working in hospitals, industry and research centres. The current thermoluminescence dosemeter (TLD) system was introduced in 1992 and the whole service changed to TLDs in 1995. The quality system compatible with the quality standards was introduced in 1999. An application for accreditation to full EN45001 and ISO/IEC Guide 25 was made in December 1999, accreditation was achieved in August 2000 by the Finnish Accreditation Service (FINAS). The considerations needed for the quality system to fulfil the requirements of the quality standards are reported. (author)

  18. Implementation of quality standards in an individual monitoring service

    Energy Technology Data Exchange (ETDEWEB)

    Hyvoenen, H.; Vartiainen, E

    2001-07-01

    In this paper the implementation of a quality system to the procedures of an individual monitoring service (IMS) is described from the practical perspective. The IMS of the Radiation and Nuclear Safety Authority (STUK) is used as an example. The IMS of STUK monitors about 8500 persons mainly working in hospitals, industry and research centres. The current thermoluminescence dosemeter (TLD) system was introduced in 1992 and the whole service changed to TLDs in 1995. The quality system compatible with the quality standards was introduced in 1999. An application for accreditation to full EN45001 and ISO/IEC Guide 25 was made in December 1999, accreditation was achieved in August 2000 by the Finnish Accreditation Service (FINAS). The considerations needed for the quality system to fulfil the requirements of the quality standards are reported. (author)

  19. Analytical chemistry in water quality monitoring during manned space missions

    Science.gov (United States)

    Artemyeva, Anastasia A.

    2016-09-01

    Water quality monitoring during human spaceflights is essential. However, most of the traditional methods require sample collection with a subsequent ground analysis because of the limitations in volume, power, safety and gravity. The space missions are becoming longer-lasting; hence methods suitable for in-flight monitoring are demanded. Since 2009, water quality has been monitored in-flight with colorimetric methods allowing for detection of iodine and ionic silver. Organic compounds in water have been monitored with a second generation total organic carbon analyzer, which provides information on the amount of carbon in water at both the U.S. and Russian segments of the International Space Station since 2008. The disadvantage of this approach is the lack of compound-specific information. The recently developed methods and tools may potentially allow one to obtain in-flight a more detailed information on water quality. Namely, the microanalyzers based on potentiometric measurements were designed for online detection of chloride, potassium, nitrate ions and ammonia. The recent application of the current highly developed air quality monitoring system for water analysis was a logical step because most of the target analytes are the same in air and water. An electro-thermal vaporizer was designed, manufactured and coupled with the air quality control system. This development allowed for liberating the analytes from the aqueous matrix and further compound-specific analysis in the gas phase.

  20. An LHCb general-purpose acquisition board for beam and background monitoring at the LHC

    International Nuclear Information System (INIS)

    In this paper we will present an LHCb custom-made acquisition board which was developed for a continuous beam and background monitoring during LHC operations at CERN. The paper describes both the conceptual design and its performance, and concludes with results from the first period of beam operations at the LHC. The main purpose of the acquisition board is to process signals from a pair of beam pickups to continuously monitor the intensity of each bunch, and to monitor the phase of the arrival time of each proton bunch with respect to the LHC bunch clock. The extreme versatility of the board also allowed the LHCb experiment to build a high-speed and high-sensitivity readout system for a fast background monitor based on a pair of plastic scintillators. The board has demonstrated very good performance and proved to be conceptually valid during the first months of operations at the LHC. Connected to the beam pickups, it provides the LHCb experiment with a real-time measurement of the total intensity of each beam and of the arrival time of each beam at the LHCb Interaction Point. It also monitors the LHC filling scheme and the beam current per bunch at a continuous rate of 40 MHz, and assures a proper global timing of LHCb. The continuous readout of the scintillators at bunch clock speed provides the LHCb experiment with high-resolution information about the beam halo and fast losses during both injection and circulating beam. It has also provided valuable information to the LHC during machine commissioning with beam. Recent results also shows that it could contribute as a luminosity monitor independent from the LHCb experiment readout system. Beam, background and luminosity measurements are continuously fed back to the LHC in the data exchange framework between the experiments and the LHC machine aimed at improving efficiently the experimental conditions real-time.

  1. A micro-pattern gaseous detector for beam monitoring in ion-therapy

    Science.gov (United States)

    Terakawa, A.; Ishii, K.; Matsuyama, S.; Kikuchi, Y.; Togashi, T.; Arikawa, J.; Yamashita, W.; Takahashi, Y.; Fujishiro, F.; Yamazaki, H.; Sakemi, Y.

    2015-12-01

    A micro-pattern gaseous detector based on gas electron multiplier technology (GEM detector) was developed as a new transmission beam monitor for charged-particle therapy to obtain real-time information about the parameters of a therapeutic beam. Feasibility tests for the GEM detector were performed using an 80-MeV proton beam to evaluate the lateral intensity distributions of a pencil beam and the dose delivered to a target. The beam intensity distributions measured with the GEM detector were in good agreement with those measured with an imaging plate while the charge output from the GEM detector was in proportion to that of a reference dose monitor of an ionization chamber design. These experimental results showed that the GEM detector can be used not only as a beam monitor for the position and two-dimensional intensity distribution but also as a dose monitor. Thus, it is possible to simultaneously measure these beam parameters for beam control in charged-particle therapy using a single GEM-based transmission monitor.

  2. Silicon detectors for the n-TOF neutron beams monitoring

    OpenAIRE

    Cosentino, L.; Musumarra, A.; Barbagallo, M.; Colonna, N.; Damone, L.; Pappalardo, A.; Piscopo, M.; Finocchiaro, P.; collaboration, for the n-TOF

    2015-01-01

    During 2014 the second experimental area EAR2 was completed at the n-TOF neutron beam facility at CERN. As the neutrons are produced via spallation, by means of a high-intensity 20 GeV pulsed proton beam impinging on a thick target, the resulting neutron beam covers an enormous energy range, from thermal to several GeV. In this paper we describe two beam diagnostic devices, designed and built at INFN-LNS, both exploiting silicon detectors coupled with neutron converter foils containing 6Li. T...

  3. Data Quality Assurance Techniques for a Monitoring and Diagnosis System

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    By researching the data quality problem in the monitoring and diagnosis system (MDS),the method of detecting non-condition data based on the development trend of equipment condition is proposed, and three requirements of criteria for detecting non-condition data: dynamic, syntheses and simplicity are discussed. According to the general mode of data management in MDS, a data quality assurance system (DQAS) comprising data quality monitoring, data quality diagnosis, detection criteria adjusting and artificial confirmation is set up. A route inspection system called MTREE realizes the DQAS. Aiming at vibration data of route inspection, two detecting criteria are made. One is the quality monitoring parameter, which is found through combining and optimizing some fundamental parameters by genetic programming (GP). The other is the quality diagnosis criterion, i. e. pseudo distance of Spectral-Energy-Vector (SEV) named Adjacent J-divergence, which indicates the variation degree of adjacent data's spectral energy distribution. Results show that DQAS, including these two criteria, is effective to improve the data quality of MDS.

  4. MONITORING OF ELECTRICAL ENERGY QUALITY ON THE TRACTION SUBSTATION INPUT

    Directory of Open Access Journals (Sweden)

    O.G. Gryb

    2015-12-01

    Full Text Available For the implementation of measures to maintain the quality of the energy industrial enterprises have to spend a significant material and monetary assets. In this regard, significant is the feasibility study of the allocation of such funds and, primarily, the determination of the economic damage arising from low quality of electricity. The reliability of the electricity metering system, relay protection and automation of modern digital substations depends on the quality of electrical energy. At the present time to improve the reliability of the substation operation it is necessary to monitor indicators of quality of electric energy, allowing you to take organizational and technical solutions for their improvement. Monitoring the power quality at the input traction substation has shown that indicators such as the coefficient of the n-th harmonic component of the voltage does not meet the standards GOST 13109-97. The source of higher harmonics is a voltage Converter used on the locomotive. To eliminate higher harmonics in the supply network for traction substations will need to install power filters. Today, the USB-analyzer of power quality «Digital measurement system of power quality» type of CSICE of accuracy class 0.2. Work energy requires reliable and quality electricity supply to consumers. The new model of balancing energy market are bilateral contracts. The main task of this market, it ensure the stable and reliable operation of the unified energy system of Ukraine, that is, transmission and supply of electricity of appropriate quality.

  5. A Remote Real-Time Monitoring System for Power Quality

    Institute of Scientific and Technical Information of China (English)

    黄治清; 贺建闽

    2003-01-01

    An introduction is made to the composition, design method and engineering application of a remote real-time monitoring system of power quality in substations based on internet. With virtual instrument and network technique adopted, this system is characterized by good real-time property, high reliability, plentiful functions, and so on. It also can be used to monitor the load of a substation, such as electric locomotives.

  6. Data Quality Monitoring for the CMS Resistive Plate Chamber Detector

    Science.gov (United States)

    Cimmino, A.; CMS Collaboration

    2011-06-01

    Resistive Plate Chambers (RPCs), with their excellent time resolution (˜ 2 ns), were chosen as dedicated muon trigger detectors for the CMS experiment. RPCs fulfill the job of muon identification, estimate the momentum and unambiguously assign bunch crossing. The critical tasks of monitoring detector performances, debugging hardware, and certifying recorded data are carried out by the RPC Data Quality Monitoring (DQM) system. We here describe the structure, functionalities, and performances of the DQM applications for the CMS RPC detector.

  7. DANIDA; Air Quality Monitoring Programme. Mission 4 Report

    Energy Technology Data Exchange (ETDEWEB)

    Sivertsen, B.

    1997-12-31

    In the development of the Environmental Information and Monitoring Programme for the Arab Republic of Egypt (EIMP), NILU is responsible for the establishment of an air pollution monitoring system. This report summarizes the fourth mission to Egypt, including planning of the second phase meetings and site visits. Additional air quality sites in Cairo have been described. A project group meeting and a visit to Egypt Meteorological Service have been reported

  8. OTR Based Monitor of Injection Beam for Top-Up Operation of the SPring-8

    CERN Document Server

    Takano, S; Masuda, T; Yamashita, A

    2005-01-01

    We have developed an OTR based monitor of injection beam at the SPring-8. The monitor has been installed near the injection point of the storage ring downstream of the beam transport line from the booster synchrotron. A screen made of an aluminum coated polyimide film is used as a nondestructive OTR radiator. A CCD camera with an electric shutter is used to observe the OTR image of the injection beam. The electric shutter is synchronized with the external injection trigger signals. At every injection, the image signal from the CCD camera is captured and analyzed by a personal computer, and the position, size and intensity of the injection beam are recorded by the common database of the SPring-8 control system. The OTR injection beam monitor provides real time and continuous diagnostic tool useful for the top-up operation of the SPring-8 storage ring.

  9. A new measurement method of electrode gains for orthogonal symmetric type beam position monitor

    CERN Document Server

    Zou, J Y; Yang, Y L; Sun, B G; Zhou, Z R; Luo, Q; Lu, P; Xu, H L

    2014-01-01

    The new beam position monitor (BPM) system of the injector at the upgrade project of Hefei Light Source (HLS II) has 19 stripline beam position monitors. Most consist of four orthogonal symmetric stripline electrodes. The differences in electronic gain and mismachining tolerance can cause the change of the beam response of the BPM electrodes. This variation will couple the two measured horizontal positions in order to bring the measuring error. To alleviate this effect, a new technique to measure the relative response of the four electrodes has been developed. It is irrelevant to the beam charge and the related coefficient can be theoretical calculated. The effect of electrodes coupling on this technique is analyzed. The calibration data is used to fit the gain for all 19 injector beam position monitors. The results show the standard deviation of the distribution of measured gains is about 5%.

  10. A secondary emission type beam profile monitor with carbon graphite ribbons

    International Nuclear Information System (INIS)

    We developed a secondary emission type beam profile monitor with carbon graphite ribbons as a beam target. The carbon graphite is excellent in endurance against heat load, and that they are thin as 1.6-3.0 micron and low z (=6) are advantage for reducing beam loss. Furthermore, since ribbons emits larger amount of electrons than ordinal metal wires because of larger surface, the monitor has higher sensitivity. The monitors were installed in the end of 3-50 BT and injection point of MR in J-PARC, in order to measure injection beam profiles by single passing. Normal size target has 32ch ribbons with 2 or 3 mm in width and their length is 200 mm each. In this paper, basic characteristics of the carbon graphite target and results of beam measurement are reported. (author)

  11. Multiparametric ionization probes for monitoring accelerated particle beams

    International Nuclear Information System (INIS)

    Paper describes high-sensitive ionization probes of transverse cross section of accelerated particle beam. Image of beam real cross section is formed at the display of electron-optical converter on the basis of multichannel plates, is recorded by TV camera and is processes and presented by means of computer. Probe structures for 1-100 MeV energy round and strip beams are developed and tested. Distortions of beam cross section image under the effect of the external magnetic field and of space charge field are estimated. The results of the first investigations into prototype ionization probes to control form, duration, phase of cyclotron beam microclusters are presented. 13 refs.; 9 figs

  12. Challenges in Data Quality Assurance in Pervasive Health Monitoring Systems

    Science.gov (United States)

    Sriram, Janani; Shin, Minho; Kotz, David; Rajan, Anand; Sastry, Manoj; Yarvis, Mark

    Wearable, portable, and implantable medical sensors have ushered in a new paradigm for healthcare in which patients can take greater responsibility and caregivers can make well-informed, timely decisions. Health-monitoring systems built on such sensors have huge potential benefit to the quality of healthcare and quality of life for many people, such as patients with chronic medical conditions (such as blood-sugar sensors for diabetics), people seeking to change unhealthy behavior (such as losing weight or quitting smoking), or athletes wishing to monitor their condition and performance. To be effective, however, these systems must provide assurances about the quality of the sensor data. The sensors must be applied to the patient by a human, and the sensor data may be transported across multiple networks and devices before it is presented to the medical team. While no system can guarantee data quality, we anticipate that it will help for the system to annotate data with some measure of confidence. In this paper, we take a deeper look at potential health-monitoring usage scenarios and highlight research challenges required to ensure and assess quality of sensor data in health-monitoring systems.

  13. Efficient generation of isolated attosecond pulses with high beam-quality by two-color Bessel-Gauss beams

    CERN Document Server

    Wang, Zhe; Zhang, Qingbin; Wang, Shaoyi; Lu, Peixiang

    2011-01-01

    The generation of isolated attosecond pulses with high efficiency and high beam quality is essential for attosec- ond spectroscopy. We numerically investigate the supercontinuum generation in a neutral rare-gas medium driven by a two-color Bessel-Gauss beam. The results show that an efficient smooth supercontinuum in the plateau is obtained after propagation, and the spatial profile of the generated attosecond pulse is Gaussian-like with the divergence angle of 0.1 degree in the far field. This bright source with high beam quality is beneficial for detecting and controlling the microscopic processes on attosecond time scale.

  14. New Fast Beam Conditions Monitoring (BCM1F) system for CMS

    International Nuclear Information System (INIS)

    The CMS Beam Radiation Instrumentation and Luminosity (BRIL) project is composed of several systems providing the experiment protection from adverse beam conditions while also measuring the online luminosity and beam background. Although the readout bandwidth of the Fast Beam Conditions Monitoring system (BCM1F—one of the faster monitoring systems of the CMS BRIL), was sufficient for the initial LHC conditions, the foreseen enhancement of the beams parameters after the LHC Long Shutdown-1 (LS1) imposed the upgrade of the system. This paper presents the new BCM1F, which is designed to provide real-time fast diagnosis of beam conditions and instantaneous luminosity with readout able to resolve the 25 ns bunch structure

  15. Gas dynamics considerations in a non-invasive profile monitor for charged particle beams

    CERN Document Server

    Tzoganis, Vasilis; Welsch, Carsten P

    2014-01-01

    A non-invasive, gas jet-based, beam profile monitor has been developed in the QUASAR Group at the Cockcroft Institute, UK. This allows on-line measurement of the 2-dimensional transverse profile of particle beams with negligible disturbance to either primary beam or accelerator vacuum. The monitor is suitable for use with beams across a wide range of energies and intensities. In this setup a nozzle-skimmer system shapes a thin supersonic gas jet into a curtain. However, the small dimensions of the gas inlet nozzle and subsequent skimmers were shown to be the cause of many operational problems. In this paper, the dynamics of gas jet formation transport and shaping is discussed before an image-processing based alignment technique is introduced. Furthermore, experimental results obtained with a 5 keV electron beam are discussed and the effects of gas stagnation pressure on the acquired beam are presented.

  16. New Fast Beam Conditions Monitoring (BCM1F) system for CMS.

    CERN Document Server

    Zagozdzinska, Agnieszka Anna

    2015-01-01

    The CMS Beam Radiation Instrumentation and Luminosity (BRIL) project is composed of several systems providing the experiment protection from adverse beam conditions while also measuring the online luminosity and beam background. Although the readout bandwidth of the Fast Beam Conditions Monitoring system (BCM1F - one of the faster monitoring systems of the CMS BRIL), was sufficient for the initial LHC conditions, the foreseen enhancement of the beams parameters after the LHC Long Shutdown-1 (LS1) imposed the upgrade of the system. This paper presents the new BCM1F, which is designed to provide real-time fast diagnosis of beam conditions and instantaneous luminosity with readout able to resolve the 25 ns sub-bunch structure.

  17. Design of a Standing-Wave Multi-Cavity Beam-Monitor for Simultaneous Beam Position and Emittance Measurements

    International Nuclear Information System (INIS)

    A high precision emittance measurement requires precise beam position at the measurement location. At present there is no existing technique, commercial or otherwise, for non-destructive pulse-to-pulse simultaneous beam position and emittance measurement. FARTECH, Inc. is currently developing a high precision cavity-based beam monitor for simultaneous beam position and emittance measurements pulse-to-pulse, without beam interception and without moving parts. The design and analysis of a multi-cavity standing wave structure for a pulse-to-pulse emittance measurement system in which the quadrupole and the dipole standing wave modes resonate at harmonics of the beam operating frequency is presented. Considering the Next Linear Collider beams, an optimized 9-cavity standing wave system is designed for simultaneous high precision beam position and emittance measurements. It operates with the π-quadrupole mode resonating at 16th harmonic of the NLC bunch frequency, and the 3 π/4 dipole mode at 12th harmonic (8.568 GHz). The 9-cavity system design indicates that the two dipoles resonate almost at the same frequency 8.583 GHz and the quadrupole at 11.427 GHz according to the scattering parameter calculations. The design can be trivially scaled so that the dipole frequency is at 8.568 GHz, and the quadrupole frequency can then be tuned during fabrication to achieve the desired 11.424 GHz. The output powers from these modes are estimated for the NLC beams. An estimated rms-beam size resolution is sub micro-meters and beam positions in sub nano-meters

  18. Construction and measurement techniques for the APS LEUTL project RF beam position monitors

    International Nuclear Information System (INIS)

    The design, construction, and assembly procedure of 24 rf beam position monitors used in the Advanced Photon Source low-energy undulator test line and linear accelerator (linac) are described. Beam stability as well as beam positioning capabilities are essential to the LEUTL project. A design objective of the LEUTL facility is to achieve better than 1- microm resolution. The highest care was used in the mechanical fabrication and assembly of the BPM units. The latest experimental results using these BPMs are presented

  19. Electron-optical monitoring of beam profile of a pulse accelerator

    International Nuclear Information System (INIS)

    Electron-optical methods of studying spatial-time characteristics of high-current electron beams on the basis of their bremsstrahlung are described. Data on dynamics of compression of electron beams of ORION-1 electrostatic accelerator, obtained under photochronographic monitoring at electron-optical converter, are presented. It is shown that in radial compression phase the rate of the beam inner boundary attains the value of ∼1.5x108 cm/s

  20. Proceedings of the meeting on beam monitors for Cyclotrons and related facilities

    International Nuclear Information System (INIS)

    The meeting on the beam monitors for Cyclotrons and related facilities was held at Institute for Nuclear Study, University of Tokyo on February 24, 1993. This proceedings contains all the paper presented at the meeting, covering the present status of the beam instruments and their performances. The coverage area of this meeting was the ion sources, the cyclotrons, the linacs, the synchrotrons and the beam transport system. The meeting consisted of 12 plenary talks and 30 scientists and engineers participated. (author)

  1. Monitoring and analyzing features of electrical power quality system performance

    Directory of Open Access Journals (Sweden)

    Genci Sharko

    2010-06-01

    Full Text Available Power quality is a set of boundaries that allows electrical systems to function in their intended manner without significant loss of performance or life. The term is used to describe electric power that drives an electrical load and the load's ability to function properly with that electric power. Without the proper quality of the power, an electrical device may malfunction, fail prematurely or not operate at all. There are many reasons why the electric power can be of poor quality and many more causes of such poor quality power. Power quality of power systems, which affects all connected electrical and electronic equipment, is a measure of deviations in voltages, currents, frequency, temperatures, winding forces and torques of particular supply systems and their components. In recent years, a considerable increase in nonlinear loads has been experienced; in particular distributed loads, such as computers, monitors and lighting, and distributed sources. The aim of this paper is to display a way of monitoring and analyzing features of electrical power quality system. As a monitoring example is taken output from power transformer rated at 320 kVA, part of distribution grid of Durres City in Albania.

  2. Fibre Monitoring System for the Beam Permit Loops at the LHC and Future Evolution of the Beam Interlock System

    CERN Document Server

    García-Argos, Carlos; Gabourin, Stéphane; Martin, Christophe; Puccio, Bruno; Siemko, Andrzej P

    2015-01-01

    The optical fibres that transmit the beam permit loop signals at the CERN accelerator complex are deployed along radiation areas. This may result in increased attenuation of the fibres, which reduces the power margin of the links. In addition, other events may cause the links to not function properly and result in false dumps, reducing the availability of the accelerator chain and affecting physics data taking. In order to evaluate the state of the fibres, an out-of-band fibre monitoring system is proposed, working in parallel to the actual beam permit loops. The future beam interlock system to be deployed during LHC long shutdown 2 will implement online, real-time monitoring of the fibres, a feature the current system lacks. Commercial off-the-shelf components to implement the optical transceivers are proposed whenever possible instead of ad-hoc designs.

  3. Water spectral pattern as holistic marker for water quality monitoring.

    Science.gov (United States)

    Kovacs, Zoltan; Bázár, György; Oshima, Mitsue; Shigeoka, Shogo; Tanaka, Mariko; Furukawa, Akane; Nagai, Airi; Osawa, Manami; Itakura, Yukari; Tsenkova, Roumiana

    2016-01-15

    Online water quality monitoring technologies have been improving continuously. At the moment, water quality is defined by the respective range of few chosen parameters. However, this strategy requires sampling and it cannot provide evaluation of the entire water molecular system including various solutes. As it is nearly impossible to monitor every single molecule dissolved in water, the objective of our research is to introduce a complimentary approach, a new concept for water screening by observing the water molecular system changes using aquaphotomics and Quality Control Chart method. This approach can continuously provide quick information about any qualitative change of water molecular arrangement without taking into account the reason of the alteration of quality. Different species and concentrations of solutes in aqueous systems structure the water solvent differently. Aquaphotomics investigates not the characteristic absorption bands of the solute in question, but the solution absorption at vibrational bands of water's covalent and hydrogen bonds that have been altered by the solute. The applicability of the proposed concept is evaluated by monitoring the water structural changes in different aqueous solutions such as acid, sugar, and salt solutions at millimolar concentration level and in ground water. The results show the potential of the proposed approach to use water spectral pattern monitoring as bio marker of water quality. Our successful results open a new venue in water quality monitoring by offering a quick and cost effective method for continuous screening of water molecular arrangement. Instead of the regular analysis of individual physical or chemical parameters, with our method - as a complementary tool - the structural changes of water molecular system used as a mirror reflecting even small disturbances in water can indicate the necessity of further detailed analysis by conventional methods. PMID:26592651

  4. Off-line data quality monitoring for the GERDA experiment

    International Nuclear Information System (INIS)

    Gerda is an experiment searching for the neutrinoless ββ decay of 76Ge. The experiment uses an array of high-purity germanium detectors, enriched in 76Ge, directly immersed in liquid argon. Gerda recently started the physics data taking using eight enriched coaxial detectors. The status of the experiment has to be closely monitored in order to promptly identify possible instabilities or problems. The on-line slow control system is complemented by a regular off-line monitoring of data quality. This ensures that data are qualified to be used in the physics analysis and allows to reject data sets which do not meet the minimum quality standards. The off-line data monitoring is entirely performed within the software framework Gelatio. In addition, a relational database, complemented by a web-based interface, was developed to support the off-line monitoring and to automatically provide information to daily assess data quality. The concept and the performance of the off-line monitoring tools were tested and validated during the one-year commissioning phase.

  5. Off-line data quality monitoring for the GERDA experiment

    Science.gov (United States)

    Zavarise, P.; Agostini, M.; Machado, A. A.; Pandola, L.; Volynets, O.

    2012-07-01

    Gerda is an experiment searching for the neutrinoless ββ decay of 76Ge. The experiment uses an array of high-purity germanium detectors, enriched in 76Ge, directly immersed in liquid argon. Gerda recently started the physics data taking using eight enriched coaxial detectors. The status of the experiment has to be closely monitored in order to promptly identify possible instabilities or problems. The on-line slow control system is complemented by a regular off-line monitoring of data quality. This ensures that data are qualified to be used in the physics analysis and allows to reject data sets which do not meet the minimum quality standards. The off-line data monitoring is entirely performed within the software framework Gelatio. In addition, a relational database, complemented by a web-based interface, was developed to support the off-line monitoring and to automatically provide information to daily assess data quality. The concept and the performance of the off-line monitoring tools were tested and validated during the one-year commissioning phase.

  6. Off-line data quality monitoring for the GERDA experiment

    CERN Document Server

    Zavarise, P; Machado, A A; Pandola, L; Volynets, O

    2011-01-01

    GERDA is an experiment searching for the neutrinoless {\\beta}{\\beta} decay of Ge-76. The experiment uses an array of high-purity germanium detectors, enriched in Ge-76, directly immersed in liquid argon. GERDA recently started the physics data taking using eight enriched coaxial detectors. The status of the experiment has to be closely monitored in order to promptly identify possible instabilities or problems. The on-line slow control system is complemented by a regular off-line monitoring of data quality. This ensures that data are qualified to be used in the physics analysis and allows to reject data sets which do not meet the minimum quality standards. The off-line data monitoring is entirely performed within the software framework GELATIO. In addition, a relational database, complemented by a web-based interface, was developed to support the off-line monitoring and to automatically provide information to daily assess data quality. The concept and the performance of the off-line monitoring tools were teste...

  7. Implementation of quality control systematics for personnel monitoring services

    International Nuclear Information System (INIS)

    The implementation of statistical quality control techniques used in industrial practise is proposed to dosimetric services. 'Control charts' and 'sampling inspection' are adapted respectively for control of measuring process and of dose results produced in routine. A chapter on Radiation Protection and Personnel Monitoring was included. (M.A.C.)

  8. Model-based monitoring of stormwater runoff quality

    DEFF Research Database (Denmark)

    Birch, Heidi; Vezzaro, Luca; Mikkelsen, Peter Steen

    2013-01-01

    find annual average (AA) and maximum event mean concentrations. Use of this model reduced the uncertainty of predicted AA concentrations compared to a simple stochastic method based solely on data. The predicted AA concentration, obtained by using passive sampler measurements (1 month installation) for......Monitoring of micropollutants (MP) in stormwater is essential to evaluate the impacts of stormwater on the receiving aquatic environment. The aim of this study was to investigate how different strategies for monitoring of stormwater quality (combining a model with field sampling) affect the...... information obtained about MP discharged from the monitored system. A dynamic stormwater quality model was calibrated using MP data collected by automatic volume-proportional sampling and passive sampling in a storm drainage system on the outskirts of Copenhagen (Denmark) and a 10-year rain series was used to...

  9. The Data Quality Monitoring for the CMS Silicon Strip Tracker

    CERN Document Server

    Adler, V; Bainbridge, R; Benucci, L; Borgia, M A; Borrello, L; Cole, J; Cripps, N; Delmeire, E; Dero, V; Dutta, S; Giordano, D; Hammad, G H; Hashemi, H; Le Bihan, A C; Le Bourgeois, M; Palmonari, F; Pierro, A; Zito, G

    2009-01-01

    The CMS Silicon Strip Tracker (SST), consisting of more than 10 million channels, is organized in about 15,000 detector modules and it is the largest silicon strip tracker ever built for high energy physics experiments. The Data Quality Monitoring system for the Tracker has been developed within the CMS Software framework. More than 100,000 monitorable quantities need to be managed by the DQM system that organizes them in a hierarchical structure reflecting the detector arrangement in subcomponents and the various levels of data processing. Monitorable quantities computed at the level of individual detectors are processed to extract automatic quality checks and summary results that can be visualized with specialized graphical user interfaces. In view of the great complexity of the CMS Tracker detector the standard visualization tools based on histograms have been complemented with 2 and 3 dimensional graphical images of the subdetector that can show the whole detector down to single channel resolution. The fu...

  10. Implementation to spanish protocol of quality control of accelerators to daily control of electron beams

    International Nuclear Information System (INIS)

    A revised procedure for daily control of the electron beams to make measurements more meaningful physically, having a better reproducibility and more in line with the recommendations of the Spanish Protocol for Quality Control in Electron Linear Accelerators Clinical Use. The daily quality control beams of high energy electrons that had been done so far was the finding that the record of a series of measures (symmetry, uniformity, stability, energy, beam central dose) were within tolerance values established. The amendment is to check the beam quality by directly measuring changes in absorption depth at which the dose is reduced to half its maximum value, R50.

  11. Influence of turbulent atmosphere on the far-field coherent combined beam quality

    Institute of Scientific and Technical Information of China (English)

    Pu Zhou; Zejin Liu; Xiaojun Xu; Xiaolin Wang; Xiao Li; Zilun Chen

    2008-01-01

    Propagation of coherent combined laser beams in turbulent atmosphere is numerically studied based on the extended Huygens-Fresnel principle. By choosing beam propagation factor (BPF) and beam quality factor (BQ) to characterize the far-field irradiance distribution properties, the influence of turbulence on far-field coherent combined beam quality is studied in detail. The investigation reveals that with the coherence length decreasing, the irradiance distribution pattern evolves from typical non-Gaussian shape with multiple side-lobes into Gaussian shape which is seen in the incoherent combining case. In weak turbulent atmosphere, the far-field beam quality suffers less when the 1aser array gets more compact and operates at a longer wavelength. In strong turbulent atmosphere, the far-field beam quality degrades into the incoherent combining case without any relationship with the fill factor and laser wavelength.

  12. SAMIRA - SAtellite based Monitoring Initiative for Regional Air quality

    Science.gov (United States)

    Schneider, Philipp; Stebel, Kerstin; Ajtai, Nicolae; Diamandi, Andrei; Horalek, Jan; Nicolae, Doina; Stachlewska, Iwona; Zehner, Claus

    2016-04-01

    Here, we present a new ESA-funded project entitled Satellite based Monitoring Initiative for Regional Air quality (SAMIRA), which aims at improving regional and local air quality monitoring through synergetic use of data from present and upcoming satellites, traditionally used in situ air quality monitoring networks and output from chemical transport models. Through collaborative efforts in four countries, namely Romania, Poland, the Czech Republic and Norway, all with existing air quality problems, SAMIRA intends to support the involved institutions and associated users in their national monitoring and reporting mandates as well as to generate novel research in this area. Despite considerable improvements in the past decades, Europe is still far from achieving levels of air quality that do not pose unacceptable hazards to humans and the environment. Main concerns in Europe are exceedances of particulate matter (PM), ground-level ozone, benzo(a)pyrene (BaP) and nitrogen dioxide (NO2). While overall sulfur dioxide (SO2) emissions have decreased in recent years, regional concentrations can still be high in some areas. The objectives of SAMIRA are to improve algorithms for the retrieval of hourly aerosol optical depth (AOD) maps from SEVIRI, and to develop robust methods for deriving column- and near-surface PM maps for the study area by combining satellite AOD with information from regional models. The benefit to existing monitoring networks (in situ, models, satellite) by combining these datasets using data fusion methods will be tested for satellite-based NO2, SO2, and PM/AOD. Furthermore, SAMIRA will test and apply techniques for downscaling air quality-related EO products to a spatial resolution that is more in line with what is generally required for studying urban and regional scale air quality. This will be demonstrated for a set of study sites that include the capitals of the four countries and the highly polluted areas along the border of Poland and the

  13. The upgraded data acquisition system for beam loss monitoring at the Fermilab Tevatron and Main Injector

    OpenAIRE

    Baumbaugh, A.; Briegel, C.; Brown, B. C.; Capista, D.; Drennan, C.; Fellenz, B.; Knickerbocker, K.; Lewis, J.D.; Marchionni, A.; Needles, C.; Olson, M.; S. Pordes; Shi, Z; Still, D.; Thurman-Keup, R.

    2011-01-01

    A VME-based data acquisition system for beam-loss monitors has been developed and is in use in the Tevatron and Main Injector accelerators at the Fermilab complex. The need for enhanced beam-loss protection when the Tevatron is operating in collider-mode was the main driving force for the new design. Prior to the implementation of the present system, the beam-loss monitor system was disabled during collider operation and protection of the Tevatron magnets relied on the quench protection syste...

  14. Albedo neutron dosimetry and monitoring around the RECH-1 reactor neutron radiographic beam

    International Nuclear Information System (INIS)

    This paper describes the neutrons and gamma monitoring and albedo neutron dosimetry in a field around the RECH-1 neutron beam. Two kind of albedo dosimeters were used: Hankins and KfK Alnor. The calibration procedures and comparison of these albedo dosimeters performance were done. The dose equivalent results agree between 28%. The neutron dose distribution for person working near the beam, was obtained by routine monitoring with albedo dosimeter developed by Hankins. A monthly neutron dose with a maximum of 0,8 mSv and arithmetic mean of 0,4 mSv were found. The beam's gamma energy spectrum and its related dose were also studied. (author)

  15. A simple method for boosting the beam quality of commercial DPL

    Institute of Scientific and Technical Information of China (English)

    张光寅; 焦志勇; 颜彩繁; 丁欣; 张潮波; 张晓华; 顾学文; 宋峰

    2003-01-01

    A simple method for boosting the beam quality of a commercial laser diode pumped laser (DPL) is put forward.By keeping one of the mirrors unchanged and the moving the other mirror a proper distance away from the laser rod,high beam quality laser output is realized.

  16. The Danish air quality monitoring programme. Annual Summary for 2007

    Energy Technology Data Exchange (ETDEWEB)

    Kemp, K.; Ellemann, T.; Brandt, J.; Christensen, Jesper; Ketzel, M.; Solvang Jensen, S.

    2008-07-15

    The air quality in Danish cities has been monitored continuously since 1982 within the Danish Air Quality Monitoring (LMP) network. The aim has been to follow the concentration levels of toxic pollutants in the urban atmosphere and to provide the necessary knowledge to assess the trends, to perform source apportionment, and to evaluate the chemical reactions and the dispersion of the pollutants in the atmosphere. In 2007 the air quality was measured in four Danish cities and at two background sites. Model calculations were also carried out to supplement the measurements. At several stations NO{sub 2} and PM{sub 10} were found in concentrations above EU limit values, which the Member States have to comply with in 2005 and 2010. The concentrations for most pollutants have been strongly decreasing since 1982, however, only a slight decrease has been observed for NO{sub 2} and O{sub 3}. (au)

  17. The Danish air quality monitoring programme. Annual summary for 2008

    Energy Technology Data Exchange (ETDEWEB)

    Kemp, K.; Ellemann, T.; Brandt, J.; Christensen, Jesper; Ketzel, M.; Solvang Jensen, S.

    2010-06-15

    The air quality in Danish cities has been monitored continuously since 1982 within the Danish Air Quality Monitoring (LMP) network. The aim has been to follow the concentration levels of toxic pollutants in the urban atmosphere and to provide the necessary knowledge to assess the trends, to perform source apportionment, and to evaluate the chemical reactions and the dispersion of the pollutants in the atmosphere. In 2007 the air quality was measured in four Danish cities and at two background sites. Model calculations were also carried out to supplement the measurements. At several stations NO{sub 2} and PM{sub 10} were found in concentrations above EU limit values, which the Member States have to comply with in 2005 and 2010. The concentrations for most pollutants have been strongly decreasing since 1982, however, only a slight decrease has been observed for NO{sub 2} and O{sub 3}. (author)

  18. Definition of Metric Dependencies for Monitoring the Impact of Quality of Services on Quality of Processes

    OpenAIRE

    Mayerl, Christian; Hüner, Kai Moritz; Gaspar, Jens-Uwe; Momm, Christof; Abeck, Sebastian

    2007-01-01

    Service providers have to monitor the quality of offered services and to ensure the compliance of service levels provider and requester agreed on. Thereby, a service provider should notify a service requester about violations of service level agreements (SLAs). Furthermore, the provider should point to impacts on affected processes in which services are invoked. For that purpose, a model is needed to define dependencies between quality of processes and quality of invoked services. In order to...

  19. Combining tissue-phantom ratios to provide a beam-quality specifier for flattening filter free photon beams

    International Nuclear Information System (INIS)

    Purpose: There are currently several commercially available radiotherapy treatment units without a flattening filter in the beam line. Unflattened photon beams have an energy and lateral fluence distribution that is different from conventional beams and, thus, their attenuation properties differ. As a consequence, for flattening filter free (FFF) beams, the relationship between the beam-quality specifier TPR20,10 and the Spencer–Attix restricted water-to-air mass collision stopping-power ratios, (L-/ρ)airwater, may have to be refined in order to be used with equivalent accuracy as for beams with a flattening filter. The purpose of this work was twofold. First, to study the relationship between TPR20,10 and (L-/ρ)airwater for FFF beams, where the flattening filter has been replaced by a metal plate as in most clinical FFF beams. Second, to investigate the potential of increasing the accuracy in determining (L-/ρ)airwater by adding another beam-quality metric, TPR10,5. The relationship between (L-/ρ)airwater and %dd(10)x for beams with and without a flattening filter was also included in this study. Methods: A total of 24 realistic photon beams (10 with and 14 without a flattening filter) from three different treatment units have been used to calculate (L-/ρ)airwater, TPR20,10, and TPR10,5 using the EGSnrc Monte Carlo package. The relationship between (L-/ρ)airwater and the dual beam-quality specifier TPR20,10 and TPR10,5 was described by a simple bilinear equation. The relationship between the photon beam-quality specifier %dd(10)x used in the AAPM’s TG-51 dosimetry protocol and (L-/ρ)airwater was also investigated for the beams used in this study, by calculating the photon component of the percentage depth dose at 10 cm depth with SSD 100 cm. Results: The calculated (L-/ρ)airwater for beams without a flattening filter was 0.3% lower, on average, than for beams with a flattening filter and comparable TPR20,10. Using the relationship in IAEA, TRS-398

  20. Data Quality Monitoring for the ATLAS trigger System during the first data taking period of the Large Hadron Collider

    CERN Document Server

    Damazio, D O; The ATLAS collaboration

    2013-01-01

    The first long period of data taking of the Large Hadron Collider was finished after 2 years of data in February 2013. The increase of the instantaneous luminosity by more than six orders of magnitude documents impressively the extraordinary success of this running period enabling the ATLAS experiment to collect data of very high quality. However, to ensure a constant and reliable monitoring and data quality assessment of the trigger's point of view, a highly flexible and powerful software framework is essential, covering many different aspects. Aside from drastically changing beam conditions as e.g. increasing pile up, the monitoring frame work has to follow up immediately and flexible all developments of the TDAQ system. The TDAQ monitoring system of ATLAS covers very different aspects as rate measurements, trigger configuration and software tests, data quality assessment and handling of events where the trigger decision has failed. Especially the data quality assessment must be made coherent at the online ...

  1. Data Quality Monitoring for the ATLAS trigger System during the first data taking period of the Large Hadron Collider

    CERN Document Server

    Oliveira Damazio, Denis; The ATLAS collaboration

    2013-01-01

    The first long period of data taking of the Large Hadron Collider was finished after 3 years of work in February 2013. The increase of the instantaneous luminosity by more than six orders of magnitude documents impressively the extraordinary success of this running period enabling the ATLAS experiment to collect very high quality data. However, to ensure a constant and reliable monitoring and data quality assessment from the trigger's point of view, a highly flexible and powerful software framework is essential, covering many different aspects. Aside from drastically changing beam conditions as e.g. increasing pile up, the monitoring frame work has to follow up immediately and in a flexible manner all developments of the TDAQ system. The TDAQ monitoring system of ATLAS covers very different aspects as rate measurements, trigger configuration and software tests, data quality assessment and handling of events where the trigger decision has failed. Especially the data quality assessment must be made coherent at ...

  2. Photoinjector beam quality improvement by shaping the wavefront of a drive laser with oblique incidence

    Institute of Scientific and Technical Information of China (English)

    HE Zhi-Gang; WANG Xiao-Hui; JIA Qi-Ka

    2012-01-01

    To increase the quantum efficiency (QE) of a copper photocathode and reduce the thermal emittance of an electron beam,a drive laser with oblique incidence was adopted in a BNL type photocathode rf gun.The disadvantageous effects on the beam quality caused by oblique incidence were analyzed qualitatively.A simple way to solve the problens through wavefront shaping was introduced and the beam quality was improved.

  3. Quality Assesment Of Photon And Electron Beams From Siemens PRIMUS Radiotherapy Accelerator

    International Nuclear Information System (INIS)

    There are two types of radiation from SIEMENS Primus Radiotherapy Accelerator at the National Cancer Hospital (K Hospital): electron and photon beams. Electron beams with four different energies of 6; 9; 12 and 15 MeV. Photon beams with two different energies: 6 MV and 15 MV. The symmetry as well as flatness of profiles created by all these beams are very important factors using in clinical practice. This report presents the method using water phantom to define absorbed dose distribution in medium of all beams. This is an effective and accurate method to define quality of radiation beams with different field sizes using in radiotherapy. (author)

  4. Bunch-length and beam-timing monitors in the SLC final focus

    International Nuclear Information System (INIS)

    During the 1997/98 luminosity run of the Stanford Linear Collider (SLC) two novel RF-based detectors were brought into operation, in order to monitor the interaction-point (IP) bunch lengths and fluctuations in the relative arrival time of the two colliding beams. Both bunch length and timing can strongly affect the SLC luminosity and had not been monitored in previous years. The two new detectors utilize a broad-band microwave signal, which is excited by the beam through a ceramic gap in the final-focus beam pipe and transported outside of the beamline vault by a 160-ft long X-Band waveguide. We describe the estimated luminosity reduction due to bunch-length drift and IP timing fluctuation, the monitor layout, the expected responses and signal levels, calibration measurements, and beam observations. copyright 1999 American Institute of Physics

  5. Beam position monitoring and feedback steering system at the photon factory

    International Nuclear Information System (INIS)

    A version of the beam steering servo system was used to vertically position and stabilize the synchrotron radiation beam at the Photon Factory. System components included a photon beam position monitor located 12 m from the bend magnet source point, a servo controller containing frequency compensation and gain circuits, and a 3-magnet orbital bump steering system. Two types of position monitor, one an ion chamber and the other on in-vacuum device, were used in the system. Vertical beam position noise spectra obtained from these monitors showed predominant peaks occurring at 14.5 Hz, 50 Hz, and at several other frequencies in the 1 to 100 Hz range. The closed-loop system was able to reduce low frequency positional offsets (< 0.1 Hz) by a factor of 1000, and the 14.5 Hz oscillation by a factor of 6

  6. Production of Inorganic Thin Scintillating Films for Ion Beam Monitoring Devices

    CERN Document Server

    Re, Maurizio; Cosentino, Luigi; Cuttone, Giacomo; Finocchiaro, Paolo; Hermanne, Alex; Lojacono, Pietro A; Ma, YingJun; Thienpont, Hugo; Van Erps, Jurgen; Vervaeke, Michael; Volckaerts, Bart; Vynck, Pedro

    2005-01-01

    In this work we present the development of beam monitoring devices consisting of thin CsI(Tl) films deposited on Aluminium support layers. The light emitted by the scintillating layer during the beam irradiation is measured by a CCD-camera. In a first prototype a thin Aluminium support layer of 6 micron allows the ion beam to easily pass through without significant energy loss and scattering effects. Therefore it turns out to be a non-destructive monitoring device to characterize on-line beam shape and beam position without interfering with the rest of the irradiation process. A second device consists of an Aluminium support layer which is thick enough to completely stop the impinging ions allowing to monitor at the same time the beam profile and the beam current intensity. Some samples have been coated by a 100 Å protective layer to prevent the film damage by atmosphere exposition. In this contribution we present our experimental results obtained by irradiating the samples with proton beams at 8.3 and 62 Me...

  7. Digital beam position and phase monitor for P-LINAC for FAIR

    International Nuclear Information System (INIS)

    For the planned P-LINAC for the FAIR facility, Beam Position Monitors (BPM) will be installed at 14 locations along the LINAC. The digital signal processing to derive the transverse beam position and the beam phase will be implemented by ''Libera Single Pass H''. The specification for position measurement is 0.1 mm spatial resolution and phase accuracy is 1 degree with respect to 325 MHz acceleration frequency. The results from the Libera digital signal processing were compared with the time-domain approach and the FFT analytic calculations. The first test was performed at the GSI UNILAC with a Ne4+ beam at 1.4 MeV / u. A single BPM was used to act as a ''Bunch arrival monitor'' to characterize the dependence of beam arrival time on bunch shape. The signals were sampled at 117.440 MHz with a 16-bit ADC to produce I and Q data streams. The first experimental results are reported.

  8. Study of beam parameters of the CERN proton linac using a three dimensional bunch shape monitor

    International Nuclear Information System (INIS)

    A Three Dimensional Bunch Shape Monitor (3D-BSM) has been developed for the CERN Proton Linac 2. A new area for beam studies at high intensities has been opened by this detector. Bunch density distributions in all three dimensions and their variations along the beam pulse can be obtained. Changing field gradients in linac quadrupoles, emittance variation along the bunch has been calculated. Measurements of beam halos become possible thanks to the large dynamic range of the device. Beam parameters at various linac settings have been measured and analysed. (author)

  9. Study of beam parameters of the CERN proton linac using a three dimensional bunch shape monitor

    CERN Document Server

    Feschenko, A V; Ostroumov, P N; Dubois, O; Haseroth, H; Hill, C; Kugler, H; Lombardi, A M; Naito, F; Tanke, E; Vretenar, Maurizio

    1996-01-01

    A Three Dimensional Bunch Shape Monitor (3D-BSM) has been developed for the CERN Proton Linac 2. A new area for beam studies at high intensities has been opened by this detector. Bunch density distributions in all three dimensions and their variations along the beam pulse can be obtained. Changing field gradients in linac quadrupoles, emittance variation along the bunch has been calculated. Measurements of beam halos become possible thanks to the large dynamic range of the device. Beam parameters at various linac settings have been measured and analysed.

  10. Definition of parameters for quality assurance of flattening filter free (FFF) photon beams in radiation therapy

    International Nuclear Information System (INIS)

    Purpose: Flattening filter free (FFF) beams generated by medical linear accelerators have recently started to be used in radiotherapy clinical practice. Such beams present fundamental differences with respect to the standard filter flattened (FF) beams, making the generally used dosimetric parameters and definitions not always viable. The present study will propose possible definitions and suggestions for some dosimetric parameters for use in quality assurance of FFF beams generated by medical linacs in radiotherapy. Methods: The main characteristics of the photon beams have been analyzed using specific data generated by a Varian TrueBeam linac having both FFF and FF beams of 6 and 10 MV energy, respectively. Results: Definitions for dose profile parameters are suggested starting from the renormalization of the FFF with respect to the corresponding FF beam. From this point the flatness concept has been translated into one of “unflatness” and other definitions have been proposed, maintaining a strict parallelism between FFF and FF parameter concepts. Conclusions: Ideas for quality controls used in establishing a quality assurance program when introducing FFF beams into the clinical environment are given here, keeping them similar to those used for standard FF beams. By following the suggestions in this report, the authors foresee that the introduction of FFF beams into a clinical radiotherapy environment will be as safe and well controlled as standard beam modalities using the existing guidelines.

  11. Longitudinal Bunch Shape Monitor Using the Beam Chopper of the J-PARC

    CERN Document Server

    Naito, F

    2004-01-01

    We propose the longitudinal bunch shape monitor for the low energy part of the linac of the J-PARC. The monitor uses the beam chopper cavity installled in the MEBT line between thr RFQ and the DTL of the J-PARC as a kind of the bunch rotator. Consequentry the longitudinal bunch shape is measured along the horizontal direction. If we can measure the energy distribution of the bunch also, the longitudinal emittance of the beam is derived. In the paper, the basic idea of the monitor is discussed in detail.

  12. A Fast Non Intercepting Linac Electron Beam Position and Current Monitor

    DEFF Research Database (Denmark)

    Hansen, Jørgen-Walther; Wille, Mads

    A non-intercepting beam monitor consisting of four detecting loops is used to determine the spatial postion and current of a pulsed beam from an electron linear accelerator. The monitor detects the magnetic field radiated by the substructure of the electron bunches created by the accelerating...... microwave. The detecting loops are interconnected two by two, by means of two coaxial hybrid junctions, the two sets positioned perpendicular to each other. By means of the two signals from the diametrically positioned detecting loops, a good spatial displacement and current monitoring sensitivity are...

  13. Quality assurance tests of the NRPB dental monitoring cassette

    International Nuclear Information System (INIS)

    This report describes the tests designed to assess the performance of the NRPB dental monitoring cassette; it complements NRPB-R164. Measurements have been made for both the original and new cassettes with film manufactured by Kodak Ltd and Agfa-Gevaert Ltd. The performance parameters investigated were the ability to measure the X-ray tube potential, the filtration of the X-ray beam, the exposure given to the cassette, and the diameter of the beam. The consistency between different cassette inserts was also assessed. The values given by the processing laboratory and the values from the irradiating laboratory are presented, and the results are then analysed statistically to determine the influence of the various parameters on the assessment of individual parameters. The performance of the cassette was found to be satisfactory. (author)

  14. Recent Advances in Point-of-Access Water Quality Monitoring

    Science.gov (United States)

    Korostynska, O.; Arshak, K.; Velusamy, V.; Arshak, A.; Vaseashta, Ashok

    Clean water is one of our most valuable natural resources. In addition to providing safe drinking water it assures functional ecosystems that support fisheries and recreation. Human population growth and its associated increased demands on water pose risks to maintaining acceptable water quality. It is vital to assess source waters and the aquatic systems that receive inputs from industrial waste and sewage treatment plants, storm water systems, and runoff from urban and agricultural lands. Rapid and confident assessments of aquatic resources form the basis for sound environmental management. Current methods engaged in tracing the presence of various bacteria in water employ bulky laboratory equipment and are time consuming. Thus, real-time water quality monitoring is essential for National and International Health and Safety. Environmental water monitoring includes measurements of physical characteristics (e.g. pH, temperature, conductivity), chemical parameters (e.g. oxygen, alkalinity, nitrogen and phosphorus compounds), and abundance of certain biological taxa. Monitoring could also include assays of biological activity such as alkaline phosphatase, tests for toxins such as microcystins and direct measurements of pollutants such as heavy metals or hydrocarbons. Real time detection can significantly reduce the level of damage and also the cost to remedy the problem. This paper presents overview of state-of-the-art methods and devices used for point-of-access water quality monitoring and suggest further developments in this area.

  15. Model-based monitoring of stormwater runoff quality.

    Science.gov (United States)

    Birch, Heidi; Vezzaro, Luca; Mikkelsen, Peter Steen

    2013-01-01

    Monitoring of micropollutants (MP) in stormwater is essential to evaluate the impacts of stormwater on the receiving aquatic environment. The aim of this study was to investigate how different strategies for monitoring of stormwater quality (combining a model with field sampling) affect the information obtained about MP discharged from the monitored system. A dynamic stormwater quality model was calibrated using MP data collected by automatic volume-proportional sampling and passive sampling in a storm drainage system on the outskirts of Copenhagen (Denmark) and a 10-year rain series was used to find annual average (AA) and maximum event mean concentrations. Use of this model reduced the uncertainty of predicted AA concentrations compared to a simple stochastic method based solely on data. The predicted AA concentration, obtained by using passive sampler measurements (1 month installation) for calibration of the model, resulted in the same predicted level but with narrower model prediction bounds than by using volume-proportional samples for calibration. This shows that passive sampling allows for a better exploitation of the resources allocated for stormwater quality monitoring. PMID:24037157

  16. Secondary emission monitor for keV ion and antiproton beams

    CERN Document Server

    Sosa, Alejandro; Bravin, Enrico; Harasimowciz, Janusz; Welsch, C P

    2013-01-01

    Beam profile monitoring of low intensity keV ion and antiproton beams remains a challenging task. A Sec- ondary electron Emission Monitor (SEM) has been de- signed to measure profiles of beams with intensities below 107 and energies as low as 20 keV. The monitor is based on a two stage microchannel plate (MCP) and a phosphor screen facing a CCD camera. Its modular design allows two different operational setups. In this contribution we present the design of a prototype and discuss results from measurements with antiprotons at the AEgIS experiment at CERN. This is then used for a characterization of the monitor with regard to its possible future use at different facilities.

  17. Performance evaluation of a beam profile monitor using Fresnel Zone Plates

    International Nuclear Information System (INIS)

    We have developed a high resolution beam profile monitor using two Fresnel Zone Plates (FZPs). To evaluate the resolution of this monitor, we computed 'Fresnel-Kirchhoff diffraction integral' to the detector position from the source point using Monte Carlo methods. From this calculation, the spatial resolution of this monitor is less than 1 μm. We also computed the effect of the inclined first FZP. And we compared with experimental result of the FZP inclination effect. (author)

  18. METEOROLOGICAL MONITORING PROGRAM. PARTICULATE MATTER AMBIENT AIR QUALITY MONITORING REPORT, JANUARY THROUGH DECEMBER 1996

    International Nuclear Information System (INIS)

    Environmental field studies in the Yucca Mountain site characterization activities have included monitoring ambient levels of particulate matter since April 1989. The monitoring and reporting work was performed by the Management and Operating Environmental Field Programs Division. The parameters monitored, methods used in the monitoring, and the sampling schedule complied with U.S. Environmental Protection Agency regulations and monitoring guidance. The inhalable particulate matter results have been reported to the State of Nevada since July 1991 to comply with State of Nevada air quality permit requirements. Three previous project reports presented the results obtained through 1995 (Environmental Field Programs Division 1992a; 1992b; 1996). This report presents the results obtained during 1996. Results of this monitoring program continue to identify that particulate matter remains well below applicable ambient air quality standards. The maximum inhalable particulate matter result was 60 micrograms per standard cubic meter; this result is less than one-half of the applicable 24-hour National (and Nevada) Ambient Air Quality Standard of 150 micrograms per standard cubic meter. The annual inhalable particulate matter averages for the period were approximately one-fifth of the applicable annual standard of 50 micrograms per standard cubic meter. The 1996 results were similar to results from 1989 to 1995

  19. Advanced monitoring of wastewater quality: data collection and data quality assurance

    DEFF Research Database (Denmark)

    Alferes, Janelcy; Lamaire-Chad, C.; Chhetri, Ravi Kumar;

    and in evaluating the impact of discharges on the receiving water bodies. As measurements are carried out under arduous conditions, practical implementation of such monitoring systems entails several challenges, and automation of data collection and data quality assessment has been recognised as a...... data being collected. In this paper, results showed the successful implementation of the proposed strategy for collection of water quality data at the inlet of a wastewater treatment plant....... critical issue. In this paper, a data quality assessment strategy is presented to achieve efficient water quality monitoring in real-world scenarios. Next to practical aspects concerning installation and maintenance of sensors, the paper also presents a software tool aimed at assessing the quality of the...

  20. South Asia transboundary water quality monitoring workshop summary report.

    Energy Technology Data Exchange (ETDEWEB)

    Betsill, Jeffrey David; Littlefield, Adriane C.; Luetters, Frederick O.; Rajen, Gaurav

    2003-04-01

    The Cooperative Monitoring Center (CMC) promotes collaborations among scientists and researchers in several regions as a means of achieving common regional security objectives. To promote cooperation in South Asia on environmental research, an international working group made up of participants from Bangladesh, India, Nepal, Pakistan, and the United States convened in Kathmandu, Nepal, from February 17-23,2002. The workshop was held to further develop the South Asia Transboundary Water Quality Monitoring (SATWQM) project. The project is sponsored in part by the CMC located at Sandia National Laboratories in Albuquerque, New Mexico through funding provided by the US. Department of State, Regional Environmental Affairs Office, American Embassy, Kathmandu, Nepal, and the National Nuclear Security Administration's (NNSA) Office of Nonproliferation and National Security. This report summarizes the SATWQM project, the workshop objectives, process and results. The long-term interests of the participants are to develop systems for sharing regional environmental information as a means of building confidence and improving relations among South Asian countries. The more immediate interests of the group are focused on activities that foster regional sharing of water quality data in the Ganges and Indus River basins. Issues of concern to the SATWQM network participants include studying the impacts from untreated sewage and industrial effluents, agricultural run-off, salinity increases in fresh waters, the siltation and shifting of river channels, and the environmental degradation of critical habitats such as wetlands, protected forests, and endangered aquatic species conservation areas. The workshop focused on five objectives: (1) a deepened understanding of the partner organizations involved; (2) garnering the support of additional regional and national government and non-government organizations in South Asia involved in river water quality monitoring; (3) identification

  1. Monitoring Burr Type III Software Quality Using SPC

    Directory of Open Access Journals (Sweden)

    Smitha Chowdary. Ch

    2015-08-01

    Full Text Available The ability of software in satisfying its functional requirements successfully is measured as software reliability, making it one of the most important characteristics of software quality. Improving software processes employed during the software development life cycle is essential to produce reliable software systems of assured quality. Software Reliability Growth Models (SRGMs aid software engineers and managers in tracking and measuring the growth in reliability as software is being developed for quality assurance. Software quality is improved by continuously monitoring and controlling the software process. Statistical Process Control (SPC is the application of statistical methods on software process data presented graphically to quickly and easily identify anomalies that enable the developer to address software failures. In this paper we proposed a SPC mechanism of control charts for time domain data using Burr Type III based on Non Homogenous Poisson Process (NHPP and parameters are estimated by Maximum likelihood Estimation (MLE method.

  2. Smart sensors for real-time water quality monitoring

    CERN Document Server

    Mason, Alex

    2013-01-01

    Sensors are being utilised to increasing degrees in all forms of industry.  Researchers and industrial practitioners in all fields seek to obtain a better understanding of appropriate processes so as to improve quality of service and efficiency.  The quality of water is no exception, and the water industry is faced with a wide array of water quality issues being present world-wide.  Thus, the need for sensors to tackle this diverse subject is paramount.  The aim of this book is to combine, for the first time, international expertise in the area of water quality monitoring using smart sensors and systems in order that a better understanding of the challenges faced and solutions posed may be available to all in a single text.

  3. Development and optimization of the LHC and the SPS beam diagnostics based on synchrotron radiation monitoring

    International Nuclear Information System (INIS)

    Measuring the beam transverse emittance is fundamental in every accelerator, in particular for colliders, where its precise determination is essential to maximize the luminosity and thus the performance of the colliding beams. Synchrotron Radiation (SR) is a versatile tool for non-destructive beam diagnostics, since its characteristics are closely related to those of the source beam. At CERN, being the only available diagnostics at high beam intensity and energy, SR monitors are exploited as the proton beam size monitor of the two higher energy machines, the Super Proton Synchrotron (SPS) and the Large Hadron Collider (LHC). The thesis work documented in this report focused on the design, development, characterization and optimization of these beam size monitors. Such studies were based on a comprehensive set of theoretical calculations, numerical simulations and experiments. A powerful simulation tool has been developed combining conventional softwares for SR simulation and optics design, thus allowing the description of an SR monitor from its source up to the detector. The simulations were confirmed by direct observations, and a detailed performance studies of the operational SR imaging monitor in the LHC, where different techniques for experimentally validating the system were applied, such as cross-calibrations with the wire scanners at low intensity (that are considered as a reference) and direct comparison with beam sizes de-convoluted from the LHC luminosity measurements. In 2015, the beam sizes to be measured with the further increase of the LHC beam energy to 7 TeV will decrease down to ∼190 μm. In these conditions, the SR imaging technique was found at its limits of applicability since the error on the beam size determination is proportional to the ratio of the system resolution and the measured beam size. Therefore, various solutions were probed to improve the system's performance such as the choice of one light polarization, the reduction of

  4. Improvement of thermo-mechanical position stability of the beam position monitor in PLS-II

    CERN Document Server

    Ha, Taekyun; Kwon, Hyuckchae; Han, Hongsik; Park, Chongdo

    2016-01-01

    In the storage ring of PLS-II, we reduced mechanical displacement of electron beam position monitors (e-BPMs) that is caused by heating during e-beam storage. The orbit feedback system intends that the electron beam pass through the center of the BPM, so to provide stable photon beam into beamlines the BPM pickup itself must be stable to sub-micrometer precision. Thermal deformation of the vacuum chambers on which the BPM pickups are mounted is inevitable when the electron beam current is changed by unintended beam abort. We reduced this deformation by improving the vacuum chamber support and by enhancing the water cooling. We report the thermo-mechanical analysis and displacement measurements of BPM pickups after the improvements.

  5. Cancellation of thermal deformation effect of the initial mirror on the beam profile monitor line

    International Nuclear Information System (INIS)

    The electron storage ring NewSUBARU has a visible light beam monitor line SR5. The two dimensional beam image obtained on this line is used in various beam diagnostics, such as a streak camera and a gated ICCD camera. One problem of this line was a stored current dependence of its imaging property. This was due to the mirror deformation produced by a heat load of synchrotron radiation. The effect of this deformation is approximated by a defocusing function in the lowest order. A simple defocusing can be handled by an adjustment of the assumed beam image position. However, the deformation was different for the horizontal and vertical directions. We installed a weak cylindrical lens to eliminate this difference. The current dependent imbalance of the deformation was cancelled by changing location of the lens according to the prediction. We succeeded to obtain a good two dimensional beam image at any electron beam energy and stored current. (author)

  6. SU-E-T-571: Newly Emerging Integrated Transmission Detector Systems Provide Online Quality Assurance of External Beam Radiation Therapy

    International Nuclear Information System (INIS)

    Purpose: Two newly emerging transmission detectors positioned upstream from the patient have been evaluated for online quality assurance of external beam radiotherapy. The prototype for the Integral Quality Monitor (IQM), developed by iRT Systems GmbH (Koblenz, Germany) is a large-area ion chamber mounted on the linac accessory tray to monitor photon fluence, energy, beam shape, and gantry position during treatment. The ion chamber utilizes a thickness gradient which records variable response dependent on beam position. The prototype of Delta4 Discover™, developed by ScandiDos (Uppsala, Sweden) is a linac accessory tray mounted 4040 diode array that measures photon fluence during patient treatment. Both systems are employable for patient specific QA prior to treatment delivery. Methods: Our institution evaluated the reproducibility of measurements using various beam types, including VMAT treatment plans with both the IQM ion chamber and the Delta4 Discover diode array. Additionally, the IQM’s effect on photon fluence, dose response, simulated beam error detection, and the accuracy of the integrated barometer, thermometer, and inclinometer were characterized. The evaluated photon beam errors are based on the annual tolerances specified in AAPM TG-142. Results: Repeated VMAT treatments were measured with 0.16% reproducibility by the IQM and 0.55% reproducibility by the Delta4 Discover. The IQM attenuated 6, 10, and 15 MV photon beams by 5.43±0.02%, 4.60±0.02%, and 4.21±0.03% respectively. Photon beam profiles were affected <1.5% in the non-penumbra regions. The IQM’s ion chamber’s dose response was linear and the thermometer, barometer, and inclinometer agreed with other calibrated devices. The device detected variations in monitor units delivered (1%), field position (3mm), single MLC leaf positions (13mm), and photon energy. Conclusion: We have characterized two new transmissions detector systems designed to provide in-vivo like measurements upstream

  7. Reliability of Beam Loss Monitor Systems for the Large Hadron Collider

    CERN Document Server

    Guaglio, Gianluca; Santoni, C

    2005-01-01

    The increase of beam energy and beam intensity, together with the use of super conducting magnets, opens new failure scenarios and brings new criticalities for the whole accelerator protection system. For the LHC beam loss protection system, the failure rate and the availability requirements have been evaluated using the Safety Integrity Level (SIL) approach. A downtime cost evaluation is used as input for the SIL approach. The most critical systems, which contribute to the final SIL value, are the dump system, the interlock system, the beam loss monitors system, and the energy monitor system. The Beam Loss Monitors System (BLMS) is critical for short and intense particles losses at 7 TeV and assisted by the Fast Beam Current Decay Monitors at 450 GeV. At medium and higher loss time it is assisted by other systems, such as the quench protection system and the cryogenic system. For BLMS, hardware and software have been evaluated in detail. The reliability input figures have been collected using historical data...

  8. Hadron-therapy beam monitoring: Towards a new generation of ultra-thin p-type silicon strip detectors

    International Nuclear Information System (INIS)

    Hadron-therapy has gained increasing interest for cancer treatment especially within the last decade. System commissioning and quality assurance procedures impose to monitor the particle beam using 2D dose measurements. Nowadays, several monitoring systems exist for hadron-therapy but all show a relatively high influence on the beam properties: indeed, most devices consist of several layers of materials that degrade the beam through scattering and energy losses. For precise treatment purposes, ultra-thin silicon strip detectors are investigated in order to reduce this beam scattering. We assess the beam size increase provoked by the Multiple Coulomb Scattering when passing through Si, to derive a target thickness. Monte-Carlo based simulations show a characteristic scattering opening angle lower than 1 mrad for thicknesses below 20 μm. We then evaluated the fabrication process feasibility. We successfully thinned down silicon wafers to thicknesses lower than 10 μm over areas of several cm2. Strip detectors are presently being processed and they will tentatively be thinned down to 20 μm. Moreover, two-dimensional TCAD simulations were carried out to investigate the beam detector performances on p-type Si substrates. Additionally, thick and thin substrates have been compared thanks to electrical simulations. Reducing the pitch between the strips increases breakdown voltage, whereas leakage current is quite insensitive to strips geometrical configuration. The samples are to be characterized as soon as possible in one of the IBA hadron-therapy facilities. For hadron-therapy, this would represent a considerable step forward in terms of treatment precision. (authors)

  9. Single shot laser flash photolysis with a fibre-coupled reference beam monitor.

    Science.gov (United States)

    Li, Heng; van 't Hag, Leonie; Yousef, Yaser A; Melø, T B; Razi Naqvi, K

    2013-02-01

    In the standard nanosecond laser photolysis method for kinetic studies, a Q-switched laser generates transient species, and absorption spectrophotometry provides a measure of their concentrations. The sample is placed between the monitoring source (a pulsed xenon arc or a flash lamp) and a monochromator, and a photomultiplier tube (PMT) is used for measuring the intensity of the light leaving the exit slit of the monochromator. With this (single-beam) arrangement, the laser-induced change in the absorbance of the sample, ΔA, can be calculated only if the intensity of the monitoring beam remains constant during the time interval of interest. When this condition is not fulfilled, a second measurement of the PMT output is made after blocking the path of the laser beam, but shot-to-shot variations in the output of the monitoring source vitiate the analysis when ΔA is small. To overcome this problem, double-beam versions were developed in the last century, but the single-beam version still enjoys greater popularity. With a view to making the double-beam method easily implementable, some simple modifications are introduced, which permit the conversion of an existing laser kinetic spectrometer into a double-beam variant (with one or two monochromators). PMID:22990442

  10. Design, construction and characterization of special ionization chambers for X radiation beams monitoring

    International Nuclear Information System (INIS)

    X radiation equipment may show fluctuations in the radiation beam intensity, as they are connected to the power net. These intensity variations can, in turn, modify the air kerma rate produced by this radiation beam. In a calibration laboratory, where radiation detectors (from clinics and hospital services) are calibrated, variations in the radiation beam intensity may cause an error in the absorbed dose determination. The monitor ionization chambers are used to verify the radiation beam intensity constancy, and to provide a correction for possible fluctuations. In this work, monitor ionization chambers for X radiation beams were designed, assembled and characterized. The developed ionization chambers have an innovative design, ring-shaped, with aluminium or graphite electrodes. These ring-shaped ionization chambers have the advantage of not interfering in the direct radiation beams. A double-volume ionization chamber with graphite electrodes was also developed. This ionization chamber is similar to the commercial monitor ionization chamber used in the Calibration Laboratory of the Instituto de Pesquisas Energeticas e Nucleares. All developed ionization chambers were tested in several standardized radiation beams and their performances were compared with those of commercial ionization chambers. The results show that two of the four ionization chambers developed showed performance comparable to that of the commercial ionization chambers tested. Besides presenting good results, the ionization chambers were designed and manufactured using low cost materials, which are easily found on the Brazilian market. (author)

  11. Noninterceptive method to measure longitudinal Twiss parameters of a beam in a hadron linear accelerator using beam position monitors

    Science.gov (United States)

    Shishlo, A.; Aleksandrov, A.

    2013-06-01

    A new method of measuring of the rms longitudinal Twiss parameters of a beam in linear accelerators is presented. It is based on using sum signals from beam position monitors sensitive to the longitudinal charge distribution in the bunch. The applicability of the method is demonstrated on the superconducting section of the Oak Ridge Spallation Neutron Source linear accelerator. The results are compared to a direct measurement of the bunch longitudinal profiles using an interceptive bunch shape monitor in the linac warm section of the same accelerator. Limitations of the method are discussed. The method is fast and simple, and can be used to obtain the initial parameters for the longitudinal matching in linear accelerators where interceptive diagnostics are not desirable.

  12. Internal quality control program for individual monitoring service

    International Nuclear Information System (INIS)

    With a focus on continuous improvement, since 2002, a special internal procedure for following and checking the performance of our individual monitoring services has been implemented. A fictitious installation, named 'Fantasma' has been created, initially, with 4 film badges and 7 thermoluminescent dosimetric ring users. Since 2005, this quality control program includes also the albedo neutron individual monitoring service. Monthly, the 'Fantasma' test monitors are irradiated by traceable Cs-137 and Am-Be sources. The calibration quantities are: the photon dose equivalent (Hx) for the photographic individual monitor, the maximum dose equivalent (MADE) for the albedo neutron individual monitor and the personal dose equivalent at 0.07 mm depth (Hp(0.07)) for ring monitor. Up to now, all results show compliance with the specific trumpet curves acceptance limits. Once, a small sub-evaluation tendency has been noted and this information was used to improve the film system. For the photographic film system, the evaluated value to reference dose ratios range from 0.71 to 1.12, with a mean value of 0.91 ± 0.12. For the ring system, the ratio ranges from 0.69 to 1.40, with a mean value of 1.02 ± 0.07. For the neutron system, which presents intrinsic larger uncertainties, the ratio ranged from 0.67 to 1.88, with mean value of 1.16 ± 0.27. (author)

  13. Energy Efficient Networks for Monitoring Water Quality in Subterranean Rivers

    Directory of Open Access Journals (Sweden)

    Fei Ge

    2016-05-01

    Full Text Available The fresh water in rivers beneath the Earth’s surface is as significant to humans as that on the surface. However, the water quality is difficult to monitor due to its unapproachable nature. In this work, we consider building networks to monitor water quality in subterranean rivers. The network node is designed to have limited functions of floating and staying in these rivers when necessary. We provide the necessary conditions to set up such networks and a topology building method, as well as the communication process between nodes. Furthermore, we provide every an node’s energy consumption model in the network building stage, the data acquiring and transmission stage. The numerical results show that the energy consumption in every node is different, and the node number should be moderate to ensure energy efficiency.

  14. Construction of a high resolution electron beam profile monitor

    International Nuclear Information System (INIS)

    Bremsstrahlung from an electron beam on a heavy target can be used to image the beam profile using collimators and slits. The limiting resolution using this system is determined by Fresnel diffraction, and is ∼ √(λd/2), where λ is the photon wavelength and d is determined by the linear dimensions of the system. For linear colliders this resolution could be a few nm. The highest resolution requires detectors which see only high energy, (small λ), photons, and this is accomplished by converting photons to pairs, and detecting Cherenkov light in a nearly forward angle with a CCD detector or streak camera. Tests are planned at the Argonne APS and SLAC FFTB

  15. Toward the next generation of air quality monitoring: Particulate Matter

    Science.gov (United States)

    Engel-Cox, Jill; Kim Oanh, Nguyen Thi; van Donkelaar, Aaron; Martin, Randall V.; Zell, Erica

    2013-12-01

    Fine particulate matter is one of the key global pollutants affecting human health. Satellite and ground-based monitoring technologies as well as chemical transport models have advanced significantly in the past 50 years, enabling improved understanding of the sources of fine particles, their chemical composition, and their effect on human and environmental health. The ability of air pollution to travel across country and geographic boundaries makes particulate matter a global problem. However, the variability in monitoring technologies and programs and poor data availability make global comparison difficult. This paper summarizes fine particle monitoring, models that integrate ground-based and satellite-based data, and communications, then recommends steps for policymakers and scientists to take to expand and improve local and global indicators of particulate matter air pollution. One of the key set of recommendations to improving global indicators is to improve data collection by basing particulate matter monitoring design and stakeholder communications on the individual country, its priorities, and its level of development, while at the same time creating global data standards for inter-country comparisons. When there are good national networks that produce consistent quality data that is shared openly, they serve as the foundation for better global understanding through data analysis, modeling, health impact studies, and communication. Additionally, new technologies and systems should be developed to expand personal air quality monitoring and participation of non-specialists in crowd-sourced data collections. Finally, support to the development and improvement of global multi-pollutant indicators of the health and economic effects of air pollution is essential to addressing improvement of air quality around the world.

  16. CMOS Smart Sensor for Monitoring the Quality of Perishables

    OpenAIRE

    Ueno, K.; Hirose, T; Asai, T.; Amemiya, Y.

    2007-01-01

    We developed a CMOS integrated-circuit sensor to monitor the change in quality of perishables that depends on surrounding temperatures. Our sensor makes use of the fact that the temperature dependence of the subthreshold current in MOSFETs is analogous to that of the degradation of perishables. The sensor is attached to perishable goods such as farm and marine products and is distributed from producers to consumers along with the goods. During their distribution process, the sensor measures t...

  17. SQUID-based beam position monitoring for proton EDM experiment

    Science.gov (United States)

    Haciomeroglu, Selcuk

    2014-09-01

    One of the major systematic errors in the proton EDM experiment is the radial B-field, since it couples the magnetic dipole moment and causes a vertical spin precession. For a proton with EDM at the level of 10-29 e.cm, 0.22 pG of B-field and 10.5 MV/m of E-field cause same vertical spin precession. On the other hand, the radial B-field splits the counter-rotating beams depending on the vertical focusing strength in the ring The magnetic field due to this split modulated at a few kHz can be measured by a SQUID-magnetometer. This measurement requires the B-field to be kept less than 1 nT everywhere around the ring using shields of mu-metal and aluminum layers. Then, the SQUID measurements involve noise from three sources: outside the shields, the shields themselves and the beam. We study these three sources of noise using an electric circuit (mimicking the beam) inside a magnetic shielding room which consists two-layers of mu-metal and an aluminum layer.

  18. A Gas-Jet Profile Monitor for the CLIC Drive Beam

    CERN Document Server

    Jeff, A; Lefevre, T; Tzoganis, V; Welsch, C P

    2013-01-01

    The Compact Linear Collider (CLIC) will use a novel acceleration scheme in which energy extracted from a very intense beam of relatively low-energy electrons (the Drive Beam) is used to accelerate a lower intensity Main Beam to very high energy. The high intensity of the Drive Beam, with pulses of more than 1015 electrons, poses a challenge for conventional profile measurements such as wire scanners. Thus, new non-invasive profile measurements are being investigated. Profile monitors using gas ionisation or fluorescence have been used at a number of accelerators. Typically, extra gas must be injected at the monitor and the rise in pressure spreads for some distance down the beam pipe. In contrast, a gas jet can be fired across the beam into a receiving chamber, with little gas escaping into the rest of the beam pipe. In addition, a gas jet shaped into a thin plane can be used like a screen on which the beam crosssectionis imaged. In this paper we present some arrangements for the generation of such a jet. In ...

  19. Data Quality Monitoring for the CMS Silicon Tracker

    CERN Document Server

    Dutta, S; Mennea, Maria Santa; Zito, G

    2006-01-01

    The CMS silicon tracker, consisting of about 17,000 detector modules and divided into micro-strip and pixel sensors, will be the largest silicon tracker ever realized for high energy physics experiments. The detector performance will be monitored using applications based on the CMS Data Quality Monitoring\\,(DQM) framework and running on the High-Level Trigger Farm as well as local DAQ systems. The monitorable quantities of this large number of modules are divided into hierarchical structures reflecting the detector sections. In addition, they are organized into structures corresponding to the levels of data processing. The information produced are delivered to client applications according to their subscription requests. The client applications summarize and visualize the quantities received. We describe here the functionalities of the CMS tracker DQM applications and report preliminary performance tests.

  20. Air quality monitoring at toxic waste sites: A Hanford perspective

    International Nuclear Information System (INIS)

    Air quality monitoring is being conducted as part of remedial investigation activities at waste sites in the 1100-EM-1 Operating Unit at the US Department of Energy's Hanford Site. Sampling is being conducted for volatile organic compounds (VOCs), semivolatile organic compounds (SVOCs) (including pesticides and PCBs), metals, and asbestos. The monitoring program is being conducted in three phases: before, during, and after intrusive remedial investigation activities. At each waste site, battery-powered monitoring equipment is positioned at one location upwind of the site (to measure background concentrations of pollutants) and typically at two locations downwind of the site. Control samples are used to identify sample contamination that may occur during handling or analysis. All samples are analyzed using methods approved by the US Environmental Protection Agency. The results from the first phase of sampling have been assessed and are being used to upgrade sampling and laboratory analysis procedures. 5 refs

  1. Participatory Patterns in an International Air Quality Monitoring Initiative

    CERN Document Server

    Sîrbu, Alina; Caminiti, Saverio; De Baets, Bernard; Elen, Bart; Francis, Louise; Gravino, Pietro; Hotho, Andreas; Ingarra, Stefano; Loreto, Vittorio; Molino, Andrea; Mueller, Juergen; Peters, Jan; Ricchiuti, Ferdinando; Saracino, Fabio; Servedio, Vito D P; Stumme, Gerd; Theunis, Jan; Tria, Francesca; Bossche, Joris Van den

    2015-01-01

    The issue of sustainability is at the top of the political and societal agenda, being considered of extreme importance and urgency. Human individual action impacts the environment both locally (e.g., local air/water quality, noise disturbance) and globally (e.g., climate change, resource use). Urban environments represent a crucial example, with an increasing realization that the most effective way of producing a change is involving the citizens themselves in monitoring campaigns (a citizen science bottom-up approach). This is possible by developing novel technologies and IT infrastructures enabling large citizen participation. Here, in the wider framework of one of the first such projects, we show results from an international competition where citizens were involved in mobile air pollution monitoring using low cost sensing devices, combined with a web-based game to monitor perceived levels of pollution. Measures of shift in perceptions over the course of the campaign are provided, together with insights int...

  2. Quality assurance in individual monitoring of ionizing radiation

    International Nuclear Information System (INIS)

    In todays world, where competition gets tougher, there is a growing consciousness of Quality Assurance (QA) and Quality Control (QC) being key elements to success. This does not only apply o manufacturing of industrial products, it is equally true for public services. Because of the increasing awareness in our modern societies of the quality of life and hence of optimal health care and general safety, it is also the general public that calls for 'products' of the highest possible quality. Good examples of the latter are the continuously improving safety standards for automobiles, for medical diagnostic imaging and for the working environment. Therefore, QA unquestionably plays a vital role in individual monitoring of ionizing radiation, especially since the media talked so many into some sort of radiation phobia. In the following an attempt is made to roughly outline some aspects that may come into play if QA is applied to routine personnel dosimetry. The author wants to emphasize that the subject, which has hardly been dealt with in the professional literature on radiation dosimetry, is a rather 'soft' one. There may be a large number of different approaches to QA, depending on special local situations and individual - sometimes national - views. It should therefore be considered as a general guide, provided in the form of (check)lists containing items of interest in routine monitoring

  3. The Danish air quality monitoring programme. Annual summary for 2005

    International Nuclear Information System (INIS)

    The air quality in Danish cities has been monitored continuously since 1982 within the Danish Air Quality (LMP) network. The aim has been to follow the concentration levels of toxic pollutants in the urban atmosphere and to provide the necessary knowledge to assess the trends, to perform source apportionment, and to evaluate the chemical reactions and the dispersion of the pollutants in the atmosphere. In 2005 the air quality was measured in four Danish cities and at two background sites. NO2 and PM10 were at several stations found in concentrations above EU limit values, which the Member States have to comply with in 2005 and 2010. While the concentrations for most other pollutants have been strongly decreasing since 1982, only a slight decrease has been observed for NO2. (au)

  4. Air quality monitoring programme. Annual summary for 2004

    Energy Technology Data Exchange (ETDEWEB)

    Kemp, K.; Ellermann, T.; Palmgren, F.; Waehlin, P.; Berkowicz, R. Brandt. j.

    2005-07-15

    The air quality in Danish cities has been monitored continuously since 1982 within the Danish Air Quality (LMP) network. The aim has been to follow the concentration levels of toxic pollutants in the urban atmosphere and to provide the necessary knowledge to assess the trends, to perform source apportionment, and to evaluate the chemical reactions and the dispersion of the pollutants in the atmosphere. In 2004 the air quality was measured in four Danish cities and at two background sites. NO{sup 2} and PM10 were at several stations found in concentrations above EU limit values, which the Member States have to comply with in 2005 and 2010. While the concentrations for most other pollutants have been strongly decreasing since 1982, only a slight decrease has been observed for NO{sup 2}. The measurement has been supplemented with dispersion models for a number of streets in Copenhagen and Aalborg. (au)

  5. Cone beam computed tomography radiation dose and image quality assessments.

    Science.gov (United States)

    Lofthag-Hansen, Sara

    2010-01-01

    Diagnostic radiology has undergone profound changes in the last 30 years. New technologies are available to the dental field, cone beam computed tomography (CBCT) as one of the most important. CBCT is a catch-all term for a technology comprising a variety of machines differing in many respects: patient positioning, volume size (FOV), radiation quality, image capturing and reconstruction, image resolution and radiation dose. When new technology is introduced one must make sure that diagnostic accuracy is better or at least as good as the one it can be expected to replace. The CBCT brand tested was two versions of Accuitomo (Morita, Japan): 3D Accuitomo with an image intensifier as detector, FOV 3 cm x 4 cm and 3D Accuitomo FPD with a flat panel detector, FOVs 4 cm x 4 cm and 6 cm x 6 cm. The 3D Accuitomo was compared with intra-oral radiography for endodontic diagnosis in 35 patients with 46 teeth analyzed, of which 41 were endodontically treated. Three observers assessed the images by consensus. The result showed that CBCT imaging was superior with a higher number of teeth diagnosed with periapical lesions (42 vs 32 teeth). When evaluating 3D Accuitomo examinations in the posterior mandible in 30 patients, visibility of marginal bone crest and mandibular canal, important anatomic structures for implant planning, was high with good observer agreement among seven observers. Radiographic techniques have to be evaluated concerning radiation dose, which requires well-defined and easy-to-use methods. Two methods: CT dose index (CTDI), prevailing method for CT units, and dose-area product (DAP) were evaluated for calculating effective dose (E) for both units. An asymmetric dose distribution was revealed when a clinical situation was simulated. Hence, the CTDI method was not applicable for these units with small FOVs. Based on DAP values from 90 patient examinations effective dose was estimated for three diagnostic tasks: implant planning in posterior mandible and

  6. Research on Monitoring Area Division of Quality Grade Changes in County Cultivated Land and Technology of Deploying Monitoring Point

    Institute of Scientific and Technical Information of China (English)

    Wei; WEI; Lijun; LIAO; Jianxin; YU

    2013-01-01

    It is an important means in management of improving both the quality and quantity of cultivated land to monitor grade changes in cultivated land quality. How to deploy monitoring network system and its point reasonably and roundly are the key to the technology of monitoring grade changes in cultivated land quality by monitoring grade changes in cultivated land quality dynamically in order to obtain the information to the index of cultivated land quality and its changes based on the existing achievements of farmland classification and grading. Spatial analysis method is used to demarcate monitoring area and deploy monitoring point according to ARCGIS,of which the result can meet the demand for monitoring grade changes in cultivated land.

  7. Monitor and DICOM viewer comparison for mammographic image quality

    International Nuclear Information System (INIS)

    Full text: There are a number of freely available software applications for viewing DICOM images. The aim of this work was to determine whether the choice of viewing software, or the monitor resolution, affects the score of a mammographic image quality phantom. Method An image of the ACR Accreditation phantom was acquired on a Siemens Mammomat 1000 X-ray unit using Fuji CR. Four medical physicists used seven different free DICOM viewers to score this image. Additionally, two physicists used Image] to score this image on 1.2, 1.8 and 3 MP monitors using a range of magnifications. Results The phantom scores for fibres, specks and masses differed by no more than half a group between the different DICOM viewers and observers. Similarly, the resolution of the monitor had no effect on the phantom score. However, scores were notably affected b zoom used. Conclusions While the choice of DICOM viewer d phantom scores, the best DICOM viewers were Image Free, based on functionality and ease of use. It is recommended that for a given monitor, the image should be scaled so that image match the monitor resolution at I:I. Standardised essential for consistent scoring of phantom images.

  8. Coral skeletal geochemistry as a monitor of inshore water quality.

    Science.gov (United States)

    Saha, Narottam; Webb, Gregory E; Zhao, Jian-Xin

    2016-10-01

    Coral reefs maintain extraordinary biodiversity and provide protection from tsunamis and storm surge, but inshore coral reef health is degrading in many regions due to deteriorating water quality. Deconvolving natural and anthropogenic changes to water quality is hampered by the lack of long term, dated water quality data but such records are required for forward modelling of reef health to aid their management. Reef corals provide an excellent archive of high resolution geochemical (trace element) proxies that can span hundreds of years and potentially provide records used through the Holocene. Hence, geochemical proxies in corals hold great promise for understanding changes in ancient water quality that can inform broader oceanographic and climatic changes in a given region. This article reviews and highlights the use of coral-based trace metal archives, including metal transported from rivers to the ocean, incorporation of trace metals into coral skeletons and the current 'state of the art' in utilizing coral trace metal proxies as tools for monitoring various types of local and regional source-specific pollution (river discharge, land use changes, dredging and dumping, mining, oil spills, antifouling paints, atmospheric sources, sewage). The three most commonly used coral trace element proxies (i.e., Ba/Ca, Mn/Ca, and Y/Ca) are closely associated with river runoff in the Great Barrier Reef, but considerable uncertainty remains regarding their complex biogeochemical cycling and controlling mechanisms. However, coral-based water quality reconstructions have suffered from a lack of understanding of so-called vital effects and early marine diagenesis. The main challenge is to identify and eliminate the influence of extraneous local factors in order to allow accurate water quality reconstructions and to develop alternate proxies to monitor water pollution. Rare earth elements have great potential as they are self-referencing and reflect basic terrestrial input. PMID

  9. Investigations into beam monitors at the AE bar {g}IS experiment

    Science.gov (United States)

    Sosa, A.; Bravin, E.; Harasimowicz, J.; Jeff, A.; Welsch, C. P.

    2014-02-01

    Detailed diagnostic of antiproton beams at low energies is required for essentially all experiments at the Antiproton Decelerator (AD), but will be particularly important for the future Extra Low ENergy Antiproton ring (ELENA) and its keV beam lines to the different experiments. Many monitors have been successfully developed and operated at the AD, but in particular beam profile monitoring remains a challenge. A dedicated beam instrumentation and detector test stand has recently been setup at the AE bar {g}IS experiment (Antimatter Experiment: Gravity, Interferometry, Spectroscopy). Located behind the actual experiment, it allows for parasitic use of the antiproton beam at different energies for testing and calibration. With the aim to explore and validate different candidate technologies for future low energy beam lines, as well as the downstream antihydrogen detector in AE bar {g}IS, measurements have been carried out using Silicon strip and pixel detectors, a purpose-built secondary emission monitor and emulsions. Here, results from measurements and characterization of the different detector types with regard to their future use at the AD complex are presented.

  10. The upgraded data acquisition system for beam loss monitoring at the Fermilab Tevatron and Main Injector

    CERN Document Server

    Baumbaugh, A; Brown, B C; Capista, D; Drennan, C; Fellenz, B; Knickerbocker, K; Lewis, J D; Marchionni, A; Needles, C; Olson, M; Pordes, S; Shi, Z; Still, D; Thurman-Keup, R; Utes, M; Wu, J

    2011-01-01

    A VME-based data acquisition system for beam-loss monitors has been developed and is in use in the Tevatron and Main Injector accelerators at the Fermilab complex. The need for enhanced beam-loss protection when the Tevatron is operating in collider-mode was the main driving force for the new design. Prior to the implementation of the present system, the beam-loss monitor system was disabled during collider operation and protection of the Tevatron magnets relied on the quench protection system. The new Beam-Loss Monitor system allows appropriate abort logic and thresholds to be set over the full set of collider operating conditions. The system also records a history of beam-loss data prior to a beam-abort event for post-abort analysis. Installation of the Main Injector system occurred in the fall of 2006 and the Tevatron system in the summer of 2007. Both systems were fully operation by the summer of 2008. In this paper we report on the overall system design, provide a description of its normal operation, and...

  11. Piezoelectric-based smart sensing system for I-beam structural health monitoring

    Science.gov (United States)

    Zhang, Chen; Zhang, Haifeng; Yu, Tzuyang; Wang, Xingwei

    2016-04-01

    In recent decades, the I-beam has become one of the most important engineering structural components being applied in areas such as mechanical, civil, and constructional engineering. To ensure safety and proper maintenance, an effective and accurate structural health monitoring method/system for I-beams is urgently needed. This paper proposes a smart sensing system for I-beam crack detection that is based on the energy diffusivity (attenuation) between two individual piezoelectric transducers (PZTs). Sensor (one of the PZTs) responses are analyzed and applied to characterize the health status of the I-beam. Lab experiments are carried out for effective evaluation of this approach in structural health monitoring. The characteristics of crack distribution are studied by calculating and analyzing the energy diffusivity variation of the sensor responses to artificially cuttings to the I-beam. Moreover, instead of utilizing an actuator and a sensor, the system employs a couple of PZTs sensors, which offer the potential for in-field, in situ sensing with the sensor arrays. This smart sensing system can be applied in railway, metro, and iron-steel structures for I-beam health monitoring applications.

  12. Quality assurance of proton beams using a multilayer ionization chamber system

    International Nuclear Information System (INIS)

    Purpose: The measurement of percentage depth-dose (PDD) distributions for the quality assurance of clinical proton beams is most commonly performed with a computerized water tank dosimetry system with ionization chamber, commonly referred to as water tank. Although the accuracy and reproducibility of this method is well established, it can be time-consuming if a large number of measurements are required. In this work the authors evaluate the linearity, reproducibility, sensitivity to field size, accuracy, and time-savings of another system: the Zebra, a multilayer ionization chamber system.Methods: The Zebra, consisting of 180 parallel-plate ionization chambers with 2 mm resolution, was used to measure depth-dose distributions. The measurements were performed for scattered and scanned proton pencil beams of multiple energies delivered by the Hitachi PROBEAT synchrotron-based delivery system. For scattered beams, the Zebra-measured depth-dose distributions were compared with those measured with the water tank. The principal descriptors extracted for comparisons were: range, the depth of the distal 90% dose; spread-out Bragg peak (SOBP) length, the region between the proximal 95% and distal 90% dose; and distal-dose fall off (DDF), the region between the distal 80% and 20% dose. For scanned beams, the Zebra-measured ranges were compared with those acquired using a Bragg peak chamber during commissioning.Results: The Zebra demonstrated better than 1% reproducibility and monitor unit linearity. The response of the Zebra was found to be sensitive to radiation field sizes greater than 12.5 × 12.5 cm; hence, the measurements used to determine accuracy were performed using a field size of 10 × 10 cm. For the scattered proton beams, PDD distributions showed 1.5% agreement within the SOBP, and 3.8% outside. Range values agreed within −0.1 ± 0.4 mm, with a maximum deviation of 1.2 mm. SOBP length values agreed within 0 ± 2 mm, with a maximum deviation of 6 mm. DDF

  13. Development of Electronics for the ATF2 Interaction Point Region Beam Position Monitor

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Youngim; /Kyungpook Natl. U.; Heo, Ae-young; /Kyungpook Natl. U.; Kim, Eun-San; /Kyungpook Natl. U.; Boogert, Stewart; /Royal Holloway, U. of London; Honda, Yosuke; /KEK, Tsukuba; Tauchi, Toshiaki; /KEK, Tsukuba; Terunuma, Nobuhiro; /KEK, Tsukuba; May, Justin; /SLAC; McCormick, Douglas; /SLAC; Smith, Tonee; /SLAC

    2012-08-14

    Nanometer resolution beam position monitors have been developed to measure and control beam position stability at the interaction point region of ATF2. The position of the beam has to be measured to within a few nanometers at the interaction point. In order to achieve this performance, electronics for the low-Q IP-BPM was developed. Every component of the electronics have been simulated and checked on the bench and using the ATF2 beam. We will explain each component and define their working range. Then, we will show the performance of the electronics measured with beam signal. ATF2 is a final focus test beam line for ILC in the framework of the ATF international collaboration. The new beam line was constructed to extend the extraction line at ATF, KEK, Japan. The first goal of ATF2 is the acheiving of a 37 nm vertical beam size at focal point (IP). The second goal is to stabilize the beam at the focal point at a few nanometer level for a long period in order to ensure the high luminosity. To achieve these goals a high resolution IP-BPM is essential. In addition for feedback applications a low-Q system is desirable.

  14. Use of active-edge silicon detectors as X-ray beam monitors

    International Nuclear Information System (INIS)

    Silicon detectors have been developed which are active to within several microns of the physical edge of the detector. These active-edge devices can be placed near an intense X-ray beam to accurately measure the X-ray beam properties. In addition, they can be fabricated in a variety of geometries that will be useful for monitoring the intensity, profile, and position of synchrotron X-ray beams. One shape is a detector with a through hole surrounded by four active elements. The hole allows the intense X-ray beam to go through the center while the four elements can detect any change in the position or dispersion of the beam. Another shape is a rectangular 5 mm longx0.5 mm wide device with a set of four elements that are 100 μm wide. These devices could be mounted on the upstream side of the jaws of an x-y collimating slit to measure the intensity profile of the beam that each jaw of the slit is stopping. Small detectors could also be mounted in a cylindrical beam stop to give on-line beam intensity measurements. A variety of different geometries were tested at beamline 10.3.1 of the Advanced Light Source using a 12.5 keV X-ray beam. They have wide dynamic range, excellent position sensitivity and low sensitivity to radiation damage

  15. 200 Hz repetition frequency joule-level high beam quality Nd:YAG nanosecond laser

    Science.gov (United States)

    Qiu, Jisi; Tang, Xiongxin; Fan, Zhongwei; Wang, Haocheng

    2016-06-01

    A joule-level Nd:YAG nanosecond laser of high repetition frequency and high beam quality is developed out. The laser is designed as a MOPA system mainly including single longitudinal mode seed, pre-amplifier unit an d power amplifier unit. In order to obtain the high-quality laser beam output, phase conjugation is adopted to compensate the laser beam distortion. Under the condition of 200 Hz high repetition frequency and 8.19 μJ single pulse energy injected by the single longitudinal mode seed, 1.53 J output energy is gained. The output laser beam is of 9 mm diameter, 7.41 ns pulse width, the far field beam spot 1.32 times the value of the diffraction limit, 1.2% energy stability (RMS) and less than 13 μrad far field beam spot angle shift.

  16. Summary report of working group 5: Beam and radiation generation, monitoring, and control

    CERN Document Server

    Church, Mike; 10.1063/1.3520295

    2012-01-01

    This paper summarizes the activities and presentations of Working Group 5 of the Advanced Accelerator Concepts Workshop held at Annapolis, Maryland in June 2010. Working Group 5 touched on a broad range of topics in the fields of beam and radiation generation and their monitoring and control. These topics were not comprehensively covered in this Workshop, but rather the Working Group concentrated on specific new developments and recent investigations. The Working Group divided its sessions into four broad categories: cathodes and electron guns, radiation generation, beam diagnostics, and beam control and dynamics. This summary is divided into the same structure.

  17. A Monitor and Control System for the Synchrotron Radiation Beam Lines at DAΦNE

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    Three synchrotron radiation beam lines have been built on DAΦNE,the Frascati electron-positron accelerator.It is Possible to monitor and control all the elements on the beam lines using a modular network distributed I/O system by National Instrunments (FieldPoint) with Bridge VIEW/Lab VIEW programs,Two of these beam lines have radiation safety problems solved by two independent and redundant systems,using mechanical switches ,and S7-200 PLC's by Siemens.In this article our solution will be described in details.

  18. Development of button-type beam position monitor for superKEKB

    International Nuclear Information System (INIS)

    Button-type beam position monitors for SuperKEKB rings have been designed. The RF characteristics such as beam response, trapped modes or wake functions have been simulated using 3-D E-M codes such as GdfidL and HFSS. The estimated instability threshold from the trapped modes was much higher than the radiation damping time. The prototype units have been tested in the prototype-antechambers installed in Nikko straight section and D6 arc sections. The mechanical reliability and the beam responses are also reported. (author)

  19. Summary report of working group 5: Beam and radiation generation, monitoring, and control

    International Nuclear Information System (INIS)

    This paper summarizes the activities and presentations of Working Group 5 of the Advanced Accelerator Concepts Workshop held at Annapolis, Maryland in June 2010. Working Group 5 touched on a broad range of topics in the fields of beam and radiation generation and their monitoring and control. These topics were not comprehensively covered in this Workshop, but rather the Working Group concentrated on specific new developments and recent investigations. The Working Group divided its sessions into four broad categories: cathodes and electron guns, radiation generation, beam diagnostics, and beam control and dynamics. This summary is divided into the same structure.

  20. Summary Report of Working Group 5: Beam and Radiation Generation, Monitoring, and Control

    International Nuclear Information System (INIS)

    This paper summarizes the activities and presentations of Working Group 5 of the Advanced Accelerator Concepts Workshop held at Annapolis, Maryland in June 2010. Working Group 5 touched on a broad range of topics in the fields of beam and radiation generation and their monitoring and control. These topics were not comprehensively covered in this Workshop, but rather the Working Group concentrated on specific new developments and recent investigations. The Working Group divided its sessions into four broad categories: cathodes and electron guns, radiation generation, beam diagnostics, and beam control and dynamics. This summary is divided into the same structure.

  1. Can Neutron Beam Components and Radiographic Image Quality be determined by the Use of Beam Purity and Sensitivity Indicators?

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1986-01-01

    radiography f a c i l i t i e s of the European Community. The direct, transfer and track-etch methods using different f i lm recording materials were used. Neutron beam components were calculated from film density measurements under the beam purity indicators and radiographic image quality was assessed by......In the Euratom Neutron Radiography Working Group Test Program beam purity and s e n s i t i v i t y indicators, as prescribed by the ASTM E 545-81 were used together with the NRWG beam purity i n d i c a t o r - f u e l and c a l i b r a t i o n fuel pin. They were radiographed together at neutron...

  2. Environmental Monitoring, Air Quality, Ambient Monitoring sites locations (includes O3, PM, and met sites), Published in 2007, NC DENR / Div. of Air Quality / Planning.

    Data.gov (United States)

    NSGIC GIS Inventory (aka Ramona) — This Environmental Monitoring, Air Quality dataset, was produced all or in part from Field Survey/GPS information as of 2007. It is described as 'Ambient Monitoring...

  3. The Study of a Beam Profile Monitor based on Faraday Cup Array

    International Nuclear Information System (INIS)

    The metal can then be discharged to measure a small current equivalent to the number of impinging ions. The beam current can be measured and used to determine the number of ions or electrons hitting the cup. Recently, beam profile monitor (BPM) based on Faraday cup array (FCA), which represented beam position through the spatial and temporal distribution of the beam current, has been studied due to advantages of measure of wide-range ion beam current. FCA system is divided into a FC, an electrical circuit and display parts. We have studied FCA to monitor beam profile on an electrostatic accelerator with wide-range ion current. In this paper, we represented basic characteristics and designs for the fabricated FCA. FCA system, which consisted of FC system, electronic readout system, and output display, was suggested to measure ion beam current, efficiently. FC system consisted of a collimator, suppressor, tiny FC, insulator frame, and circuit board divided into elec PCB, cap PCB, and con PCB. FC size was 4 mm diameters and FCA system was considered as 8 x 8 array and whole size of 8 x 8 mm''2. FCA system was set-up in vacuum chamber and an integrator and output display parts were formed out of chamber to minimize number of feed-through

  4. The Study of a Beam Profile Monitor based on Faraday Cup Array

    Energy Technology Data Exchange (ETDEWEB)

    Park, K. M.; Park, S. H.; Kim, S. G.; Kwon, H. J.; Cho, Y. S. [KAERI, Daejeon (Korea, Republic of)

    2015-05-15

    The metal can then be discharged to measure a small current equivalent to the number of impinging ions. The beam current can be measured and used to determine the number of ions or electrons hitting the cup. Recently, beam profile monitor (BPM) based on Faraday cup array (FCA), which represented beam position through the spatial and temporal distribution of the beam current, has been studied due to advantages of measure of wide-range ion beam current. FCA system is divided into a FC, an electrical circuit and display parts. We have studied FCA to monitor beam profile on an electrostatic accelerator with wide-range ion current. In this paper, we represented basic characteristics and designs for the fabricated FCA. FCA system, which consisted of FC system, electronic readout system, and output display, was suggested to measure ion beam current, efficiently. FC system consisted of a collimator, suppressor, tiny FC, insulator frame, and circuit board divided into elec PCB, cap PCB, and con PCB. FC size was 4 mm diameters and FCA system was considered as 8 x 8 array and whole size of 8 x 8 mm''2. FCA system was set-up in vacuum chamber and an integrator and output display parts were formed out of chamber to minimize number of feed-through.

  5. Two-dimensional beam profile monitor having high dynamic range by using multi-screen

    International Nuclear Information System (INIS)

    A two-dimensional beam profile monitor with a high dynamic range for 3-50 BT at J-PARC has been developed. For measuring the beam core and the halo alternatively, the monitor has three kinds of screens. The first one is titanium foil OTR screen (thickness of 10 μm) to measure a beam core, the second one is aluminum foil OTR screen (thickness of 100 μm) having a hole (50 mm diameter) in the center, and the last one is a pair of alumina fluorescent screen with a separation of 80 mm in horizontal to observe the beam halo in surroundings. We designed an optical system based on the Offner optics for the observation of fluorescence and OTR lights. This optical system has an entrance aperture of 300 mm and it can cover the large opening angle (+/- 13.5 degree) of the OTR from 3 GeV protons. A CID camera with an image intensifier (I.I.) was use to observe the profile. We have succeeded to observe a profile of beam halo to 10-6 order to the peak of beam core by using proton beams of 3 GeV, 9.6 x 1012 protons/2bunch by this multi-screen scheme. (author)

  6. Theoretical and numerical studies on the transport of transverse beam quality in plasma-based accelerators

    OpenAIRE

    Mehrling, Timon

    2014-01-01

    This work examines effects, which impact the transverse quality of electron-beams in plasma-based accelerators, by means of theoretical and numerical methods. Plasma-based acceleration is a promising candidate for future particle accelerator technologies. In plasma-based acceleration, highly intense laser beams or high-current relativistic particle beams are focused into a plasma to excite plasma-waves with extreme transverse and longitudinal electric fields. The amplitude of these fields exc...

  7. Intense high-quality medical proton beams via laser fields

    CERN Document Server

    Galow, Benjamin J; Keitel, Christoph H

    2010-01-01

    Simulations based on the coupled relativistic equations of motion show that protons stemming from laserplasma processes can be efficiently post-accelerated employing crossed pulsed laser beams focused to spot radii on the order of the laser wavelength. We demonstrate that the crossed beams produce quasi-monoenergetic accelerated protons with kinetic energies exceeding 200 MeV, small energy spreads of about 1% and high densities as required for hadron cancer therapy.

  8. TH-C-17A-09: Direct Visualization and Monitoring of Medical Radiation Beams in Air

    Energy Technology Data Exchange (ETDEWEB)

    Fahimian, B; Ceballos, A; Turkcan, S; Kapp, D; Pratx, G [Stanford University, Stanford, CA (United States)

    2014-06-15

    Purpose: Radiation therapy errors are rare but potentially catastrophic. Recent fatal incidents could have been avoided by utilizing real-time methods of monitoring delivery of radiation during treatment. However, few existing methods are practical enough to be used routinely. The study presents the first experimental demonstration of a novel non-perturbing method of monitoring radiation therapy through the phenomena of air scintillation. Methods: Monitoring of radiation delivery was devised by leveraging the phenomena of nitrogen excitation in air by ionizing radiation. The excitation induced weak luminescence in the 300–400 nm range, a process called air scintillation. An electron-multiplication charge-coupled device camera (f/0.95 lens; 440 nm shortpass) was set-up in a clinical treatment vault and was used to capture air scintillation images of kilovoltage and megavoltage beams. Monte Carlo simulations were performed to determine the correlation of radiation dose to air scintillation. Results: Megavoltage beams from a Varian Clinac 21EX and kilovoltage beams from an orthovoltage unit (50 kVp, 30 mA) were visualized with a relatively short exposure time (10 s). Cherenkov luminescence produced in a plastic transparent phantom did not interfere with detection of air scintillation. The image intensity displayed an inverse intensity falloff (r{sup 2} = 0.89) along the central axis and was proportional to dose rate (r{sup 2} = 0.9998). As beam energy increased, the divergence of the imaged beam decreased. Last, air scintillation was visualized during a simulated total skin irradiation electron treatment. Conclusion: Air scintillation can be clinically detected to monitor a radiation beam in an inexpensive and non-perturbing manner. This new method is advantageous in monitoring for gross delivery and uniquely capable of wide area in a single acquisition, such as the case for online verification of total body / skin / lymphoid irradiation treatments.

  9. The Danish air quality monitoring programme. Annual summary for 2012

    Energy Technology Data Exchange (ETDEWEB)

    Ellermann, T.; Klenoe Noejgaard, J.; Nordstroem, C.; Brandt, J.; Christensen, Jesper; Ketzel, M.; Jansen, S.; Massling, A.; Solvang Jensen, S.

    2013-10-15

    The air quality in Danish cities has been monitored continuously since 1982 within the Danish Air Quality Monitoring network. The aim is to follow the concentration levels of toxic pollutants in the urban atmosphere and to provide the necessary knowledge to assess the trends, to perform source apportionment, and to understand the governing processes that determine the level of air pollution in Denmark. In 2012 the air quality was measured in four Danish cities and at two background sites. In addition model calculations were carried out to supplement the measurements. At one street station (H.C. Andersens Boulevard) in Copenhagen NO{sub 2} was found in concentrations above EU limit values while NO{sub 2} levels in Odense, Aarhus and Aalborg were below the limit value. Model calculations indicate exceedances of NO{sub 2} limit values at several streets in Copenhagen. Annual averages of PM{sub 10} and PM{sub 2.5} were below limit values at all stations. The concentrations for most pollutants have been decreasing during the last decades. (Author)

  10. The Danish air quality monitoring programme. Annual summary for 2011

    Energy Technology Data Exchange (ETDEWEB)

    Ellemann, T.; Klenoe Noejgaard, J.; Nordstroem, C.; Brandt, J.; Christensen, Jesper; Ketzel, M.; Solvang Jensen, S.

    2012-10-15

    The air quality in Danish cities has been monitored continuously since 1982 within the Danish Air Quality Monitoring network. The aim is to follow the concentration levels of toxic pollutants in the urban atmosphere and to provide the necessary knowledge to assess the trends, to perform source apportionment, and to understand the governing processes that determine the level of air pollution in Denmark. In 2011 the air quality was measured in four Danish cities and at two background sites. In addition model calculations were carried out to supplement the measurements. At one street station (H.C. Andersens Boulevard) in Copenhagen NO{sub 2} was found in concentrations above EU limit values while NO{sub 2} levels in Odense, Aarhus and Aalborg were below the limit value. Model calculations indicate exceedances of NO{sub 2} limit values at several streets in Copenhagen. Annual averages of PM{sub 10} and PM{sub 2.5} were below limit values at all stations. However, concentrations levels in Copenhagen exceeded the daily limit value for PM{sub 10}. Winter salting of roads was one of the main reasons for this exceedance. The concentrations for most pollutants have been strongly decreasing during the last decades, however, only a slight decrease has been observed for NO{sub 2} and O{sub 3}. (Author)

  11. Anisotropic pure-phase plates for quality improvement of partially coherent, partially polarized beams

    Science.gov (United States)

    MartíNez-Herrero, Rosario; MejíAs, Pedro M.; Piquero, Gemma

    2003-03-01

    From a theoretical point of view, the use of anisotropic pure-phase plates (APP) is considered in order to improve the quality parameter of certain partially coherent, partially polarized beams. It is shown that, to optimize the beam-quality parameter, the phases of the two Cartesian components of the field at the output of the APP plate should be identical and should exhibit a quadratic dependence on the radial polar coordinate.

  12. A beam intensity monitor for the Loma Linda cancer therapy proton accelerator

    International Nuclear Information System (INIS)

    A beam intensity monitor was tested in a 230-MeV proton beam at the Loma Linda Proton Therapy Accelerator during its commissioning at Fermi National Accelerator Laboratory. The intensity monitor was designed to regulate the beam intensity extracted from the proton synchrotron. The proton beam is tunable between 70 and 250 MeV with an adjustable intensity between 1010 and 1011 protons per spill. A beam spill is typically 1 s long with a 2-s repetition period. The intensity monitor must be radiation hard, expose minimum mass to the beam, and measure intensity to 1% in 1-ms time intervals. To this end, a 5-cm-thick xenon gas scintillator optically coupled to a photomultiplier tube (PMT) was tested to measure its response to the proton beam. The gas cell was operated at 1.2 atm of pressure and has 12.7-μm-thick titanium entrance and exit foils. The total mass exposed to the beam is 0.14 g/cm2 and is dominated by the titanium windows. This mass corresponds to a range attenuation equal to 1.4 mm of water. The energy lost to the xenon gas is about 70 keV per proton. Each passing proton will produce approximately 2000 photons. With a detection efficiency on the order of 0.05% for this UV light, one would anticipate over 1010 photoelectrons per second. In a 1-ms time bin there will be approximately 107 photoelectrons. This yields a resolution limited by systematics. For unregulated 0.4-s proton spills, we observe a response bandwidth in excess of 104 Hz. While signal-to-noise and linearity were not easily measured, we estimate as few as 103 protons can be observed suggesting a dynamic range in excess of 105 is available

  13. A beam intensity monitor for the Loma Linda cancer therapy proton accelerator.

    Science.gov (United States)

    Coutrakon, G; Miller, D; Kross, B J; Anderson, D F; DeLuca, P; Siebers, J

    1991-01-01

    A beam intensity monitor was tested in a 230-MeV proton beam at the Loma Linda Proton Therapy Accelerator during its commissioning at Fermi National Accelerator Laboratory. The intensity monitor was designed to regulate the beam intensity extracted from the proton synchrotron. The proton beam is tunable between 70 and 250 MeV with an adjustable intensity between 10(10) and 10(11) protons per spill. A beam spill is typically 1 s long with a 2-s repetition period. The intensity monitor must be radiation hard, expose minimum mass to the beam, and measure intensity to 1% in 1-ms time intervals. To this end, a 5-cm-thick xenon gas scintillator optically coupled to a photomultiplier tube (PMT) was tested to measure its response to the proton beam. The gas cell was operated at 1.2 atm of pressure and has 12.7-microns-thick titanium entrance and exit foils. The total mass exposed to the beam is 0.14 g/cm2 and is dominated by the titanium windows. This mass corresponds to a range attenuation equal to 1.4 mm of water. The energy lost to the xenon gas is about 70 keV per proton. Each passing proton will produce approximately 2000 photons. With a detection efficiency on the order of 0.05% for this UV light, one would anticipate over 10(10) photoelectrons per second. In a 1-ms time bin there will be approximately 10(7) photoelectrons. This yields a resolution limited by systematics. For unregulated 0.4-s proton spills, we observe a response bandwidth in excess of 10(4) Hz. While signal-to-noise and linearity were not easily measured, we estimate as few as 10(3) protons can be observed suggesting a dynamic range in excess of 10(5) is available. PMID:1656180

  14. Quality assurance of environmental gamma radiation monitoring in Slovenia

    International Nuclear Information System (INIS)

    Environmental gamma radiation monitoring established in Slovenia consists of a network of multifunctional gamma monitors (MFMs) based on pairs of Geiger-Mueller counters and a network of measuring sites with high-sensitive thermoluminescence dosemeters. The measuring points are evenly spread across Slovenia, located at the meteorological stations and more densely on additional locations around the Krsko NPP. The MFM network has a 2-fold function with one sensor used for the purpose of early warning system in near surroundings of the NPP and the other, more sensitive, for natural radiation monitoring. The paper summarises activities to establish quality assurance of the environmental gamma radiation measurements in Slovenia, with a critical view of the results in comparison with the international standards and recommendations. While the results of linearity and energy dependence tests were satisfying, on-field intercomparison showed that the inherent signal of one of the monitors (MFM) has to be taken into account in the range of environmental background radiation. (authors)

  15. Performance of a fast acquisition system for in-beam PET monitoring tested with clinical proton beams

    Science.gov (United States)

    Piliero, M. A.; Bisogni, M. G.; Cerello, P.; Del Guerra, A.; Fiorina, E.; Liu, B.; Morrocchi, M.; Pennazio, F.; Pirrone, G.; Wheadon, R.

    2015-12-01

    In this work we present the performance of a fast acquisition system for in-beam PET monitoring during the irradiation of a PMMA phantom with a clinical proton beam. The experimental set-up was based on 4 independent detection modules. Two detection modules were placed at one side of a PMMA phantom and the other two modules were placed at the opposite side of the phantom. One detection module was composed of a Silicon Photon Multiplier produced by AdvanSiD coupled to a single scintillating LYSO crystal. The read-out system was based on the TOFPET ASIC managed by a Xilinx ML605 FPGA Evaluation Board (Virtex 6). The irradiation of the PMMA phantom was performed at the CNAO hadrontherapy facility (Pavia, Italy) with a 95 MeV pulsed proton beam. The pulsed time structure of the proton beam was reconstructed by each detection module. The β+ annihilation peak was successfully measured and the production of β+ isotopes emitters was observed as increasing number of 511 keV events detected during irradiation. Finally, after the irradiation, the half lives of the 11C and 15O radioactive isotopes were estimated.

  16. Monitoring asthma in childhood: symptoms, exacerbations and quality of life.

    Science.gov (United States)

    Brand, Paul L P; Mäkelä, Mika J; Szefler, Stanley J; Frischer, Thomas; Price, David

    2015-06-01

    Monitoring asthma in children in clinical practice is primarily performed by reviewing disease activity (daytime and night-time symptoms, use of reliever medication, exacerbations requiring frequent use of reliever medication and urgent visits to the healthcare professional) and the impact of the disease on children's daily activities, including sports and play, in a clinical interview. In such an interview, most task force members also discuss adherence to maintenance therapy and the patients' (and parents') views and beliefs on the goals of treatment and the amount of treatment required to achieve those goals. Composite asthma control and quality of life measures, although potentially useful in research, have limited value in clinical practice because they have a short recall window and do not cover the entire spectrum of asthma control. Telemonitoring of children with asthma cannot replace face-to-face follow-up and monitoring because there is no evidence that it is associated with improved health outcomes. PMID:26028631

  17. Monitoring the electron beam position at the TESLA test facility free electron laser

    International Nuclear Information System (INIS)

    The operation of a free electron laser working in the Self Amplified Spontaneous Emission mode (SASE FEL) requires the electron trajectory to be aligned with very high precision in overlap with the photon beam. In order to ensure this overlap, one module of the SASE FEL undulator at the TESLA Test Facility (TTF) is equipped with a new type of waveguide beam position monitor (BPM). Four waveguides are arranged symmetrically around the beam pipe, each channel couples through a small slot to the electromagnetic beam field. The induced signal depends on the beam intensity and on the transverse beam position in terms of beam-to-slot distance. With four slot--waveguide combinations a linear position sensitive signal can be achieved, which is independent of the beam intensity. The signals transduced by the slots are transferred by ridged waveguides through an impedance matching stage into a narrowband receiver tuned to 12 GHz. The present thesis describes design, tests, and implementation of this new type of BPM. (orig.)

  18. Silicon detectors for monitoring neutron beams in n-TOF beamlines.

    Science.gov (United States)

    Cosentino, L; Musumarra, A; Barbagallo, M; Colonna, N; Damone, L; Pappalardo, A; Piscopo, M; Finocchiaro, P

    2015-07-01

    During 2014, the second experimental area (EAR2) was completed at the n-TOF neutron beam facility at CERN (n-TOF indicates neutron beam measurements by means of time of flight technique). The neutrons are produced via spallation, by means of a high-intensity 20 GeV pulsed proton beam impinging on a thick target. The resulting neutron beam covers the energy range from thermal to several GeV. In this paper, we describe two beam diagnostic devices, both exploiting silicon detectors coupled with neutron converter foils containing (6)Li. The first one is based on four silicon pads and allows monitoring of the neutron beam flux as a function of the neutron energy. The second one, in beam and based on position sensitive silicon detectors, is intended for the reconstruction of the beam profile, again as a function of the neutron energy. Several electronic setups have been explored in order to overcome the issues related to the gamma flash, namely, a huge pulse present at the start of each neutron bunch which may blind the detectors for some time. The two devices were characterized with radioactive sources and also tested at the n-TOF facility at CERN. The wide energy and intensity range they proved capable of sustaining made them attractive and suitable to be used in both EAR1 and EAR2 n-TOF experimental areas, where they became immediately operational. PMID:26233385

  19. Beam-spot temperature monitoring on the production target at the BigRIPS separator

    International Nuclear Information System (INIS)

    Since 2007, a water-cooled high-power rotating disk target has been in operation at the in-flight radioactive-isotope beam separator (BigRIPS), RIKEN. The target should withstand a goal beam intensity of 1 particle μA (pμA) 238U-beam at 350 AMeV with a spot size of 1 mm in diameter, resulting in a heat deposit of 22 kW in the target. A beam-spot temperature monitoring system using infrared devices in high-radiation environment was elaborately developed. The beam-spot temperature on a beryllium (Be) fixed target and on a rotating Be and tungsten (W) disk target was measured with the most intense beams presently available at our facility. The heat deposit achieved was 0.6 kW, that is 1/37 of the goal value. At the present beam intensity, the result supports our estimation that a water-cooled rotating disk target of 30 cm diameter can withstand an approximately tenfold beam intensity compared to a water-cooled fixed target.

  20. Monitoring the electron beam position at the TESLA test facility free electron laser

    Energy Technology Data Exchange (ETDEWEB)

    Kamps, T.

    2000-06-14

    The operation of a free electron laser working in the Self Amplified Spontaneous Emission mode (SASE FEL) requires the electron trajectory to be aligned with very high precision in overlap with the photon beam. In order to ensure this overlap, one module of the SASE FEL undulator at the TESLA Test Facility (TTF) is equipped with a new type of waveguide beam position monitor (BPM). Four waveguides are arranged symmetrically around the beam pipe, each channel couples through a small slot to the electromagnetic beam field. The induced signal depends on the beam intensity and on the transverse beam position in terms of beam-to-slot distance. With four slot--waveguide combinations a linear position sensitive signal can be achieved, which is independent of the beam intensity. The signals transduced by the slots are transferred by ridged waveguides through an impedance matching stage into a narrowband receiver tuned to 12 GHz. The present thesis describes design, tests, and implementation of this new type of BPM. (orig.)

  1. Preliminary beam experiment and parameter simulation for cavity beam position monitor

    International Nuclear Information System (INIS)

    Background: Aiming at precise beam position measurement of next generation FEL facility, Shanghai institute of applied physics developed 5712 MHz high Q CBPM prototype. Purpose: ADC bits and data length of data acquisition system are key parameters influencing spatial resolution of CBPM. In order to find the optimized configuration parameters, dedicated beam experiments and corresponding Monte Carlo simulations were used to solve the problems. Methods: The position calibration factors of CBPM prototype have been obtained through beam based calibration experiment at the Shanghai deep ultraviolet FEL facility. The dependence between system spatial resolution and ADC bits and the data length have been simulated with the measured position calibration factors by using Monte Carlo method. Results: Equipped with 14 bits or better ADCs IF sampling technique is capable to achieve submicron position resolution, which is the optimal choice for CBPM on-line data acquisition system. Applying FFT signal processing algorithm, optimal data lengths in RF and IF sampling techniques were respectively 8192 and 256 points. Conclusions: RF sampling technique is hard to accomplish precise measurement of submicron level due to limited bits of present ultra- high-speed ADC, but suitable for plug and play prototype parameter test and evaluation. (authors)

  2. Monitoring roof beam lateral displacement at the waste isolation pilot plant

    International Nuclear Information System (INIS)

    Lateral displacement in the immediate roof beam at the Waste Isolation Pilot Plant (WIPP) is a significant factor in assessment of excavation performance for the design of ground control systems. Information on roof beam lateral displacement, expansion, fracture formation, as well as excavation convergence, is gathered using a variety of manually and remotely read instruments. Visual observations are also used when possible. This paper describes the methods used to measure lateral displacement, or offset, at the WIPP. Offset magnitudes are determined by the degree of occlusion in drillholes that intersect the offset plane. The Borehole Lateral Displacement Sensor (BLDS) was developed for installation at WIPP to monitor offset at a high degree of accuracy at a short reading frequency. Offset measurements have historically been obtained by visual estimation of borehole occlusion. Use of the BLDS will enable relationships between time dependent roof beam lateral displacement and expansion to be established in much shorter periods than is possible using visual observations. The instrument will also allow remote monitoring of roof beam displacement in areas where visual estimations are not possible. Continued monitoring of roof beam displacement, convergence, and expansion, is integral to timely and pertinent assessments of WIPP excavation performance

  3. Systems for monitoring and digitally recording water-quality parameters

    Science.gov (United States)

    Smoot, George F.; Blakey, James F.

    1966-01-01

    Digital recording of water-quality parameters is a link in the automated data collection and processing system of the U.S. Geological Survey. The monitoring and digital recording systems adopted by the Geological Survey, while punching all measurements on a standard paper tape, provide a choice of compatible components to construct a system to meet specific physical problems and data needs. As many as 10 parameters can be recorded by an Instrument, with the only limiting criterion being that measurements are expressed as electrical signals.

  4. Energy monitoring and quality control of a single screw extruder

    International Nuclear Information System (INIS)

    Highlights: • A simple real-time energy monitoring method has been developed for polymer extruder. • The effect of process settings on energy consumption has been investigated. • A complete monitoring and control system for polymer extrusion has been developed. • A feedback control system based on fuzzy logic has been developed and validated. - Abstract: Polymer extrusion, in which a polymer is melted and conveyed to a mould or die, forms the basis of most polymer processing techniques. Extruders frequently run at non-optimised conditions and can account for 15–20% of overall process energy losses. In times of increasing energy efficiency such losses are a major concern for the industry. Product quality, which depends on the homogeneity and stability of the melt flow which in turn depends on melt temperature and screw speed, is also an issue of concern of processors. Gear pumps can be used to improve the stability of the production line, but the cost is usually high. Likewise it is possible to introduce energy meters but they also add to the capital cost of the machine. Advanced control incorporating soft sensing capabilities offers opportunities to this industry to improve both quality and energy efficiency. Due to strong correlations between the critical variables, such as the melt temperature and melt pressure, traditional decentralized PID (Proportional–Integral–Derivative) control is incapable of handling such processes if stricter product specifications are imposed or the material is changed from one batch to another. In this paper, new real-time energy monitoring methods have been introduced without the need to install power meters or develop data-driven models. The effects of process settings on energy efficiency and melt quality are then studied based on developed monitoring methods. Process variables include barrel heating temperature, water cooling temperature, and screw speed. Finally, a fuzzy logic controller is developed for a single

  5. Monitoring of Milk Quality With Disposable Taste Sensor

    Directory of Open Access Journals (Sweden)

    Muhammad Suzuri Hitam

    2003-09-01

    Full Text Available A disposable screen-printed multi channel taste sensor composed of several types of lipid as transducers and a computer as data analyzer could detect taste in a manner similar to human gustatory sensation. The disposable taste sensor was used to measure the electrical potential resulted from the interaction between lipid membranes and taste substances. In the present study, two types of packaged commercial milk, the ultra high temperature (UHT and the pasteurized milk were tested. It was found that the disposable taste sensor is capable to discriminate reliably between fresh and spoiled milk and to follow the deterioration of the milk quality when it is stored at room temperature based on a pattern recognition principle namely Principle Component Analysis (PCA. This research could provide a new monitoring method ideally for simple and cheap decentralized testing for controlling the quality of milk, which may be of great use in the dairy industries.

  6. Biological monitoring and selected trends in environmental quality

    International Nuclear Information System (INIS)

    Under a contract with the President's Council on Environmental Quality, the National Inventory of Selected Biological Monitoring Programs at ORNL was used to identify documented environmental trends. Fish population trends were described for the Great Lakes and the Colorado River system. Trends in amphibian populations in the northeast were examined and correlated with acid precipitation. Increases in breeding success among large birds of prey were correlated with reductions in ambient levels of DDT and its residues. Geographic variation in PCB contamination was examined along with differences between aquatic and terrestrial contamination levels. Changes in air quality were documented, and their effects on plant viability were outlined. Trends in the biological effects of environmental deposition of lead were documented. Long-term changes in forest structure in the southeast were presented, and a general reduction in wildlife habitat, associated with land use practices, was documented for several areas in the US

  7. QualitySpy: a framework for monitoring software development processes

    Directory of Open Access Journals (Sweden)

    Marian Jureczko

    2012-03-01

    Full Text Available The growing popularity of highly iterative, agile processes creates increasing need for automated monitoring of the quality of software artifacts, which would be focused on short terms (in the case of eXtreme Programming process iteration can be limited to one week. This paper presents a framework that calculates software metrics and cooperates with development tools (e.g. source version control system and issue tracking system to describe current state of a software project with regard to its quality. The framework is designed to support high level of automation of data collection and to be useful for researchers as well as for industry. The framework is currently being developed hence the paper reports already implemented features as well as future plans. The first release is scheduled for July.

  8. Operating results for the beam profile monitor system currently in use at Bevalac Facility

    International Nuclear Information System (INIS)

    Three stations of a soon to be completed multi-station, multi-wire beam monitoring system have been installed in the Bevalac transfer line. The following article will provide a cursory analysis of the electronic circuitry, discuss new design additions and summarize the operating results obtained over the last year

  9. An LHCb general-purpose acquisition board for beam and background monitoring at the LHC

    CERN Document Server

    Alessio, F; Guzik, Z

    2011-01-01

    In this paper we will present an LHCb custom-made acquisition board which was developed for a continuous beam and background monitoring during LHC operations at CERN. The paper describes both the conceptual design and its performance, and concludes with results from the first period of beam operations at the LHC. The main purpose of the acquisition board is to process signals from a pair of beam pickups to continuously monitor the intensity of each bunch, and to monitor the phase of the arrival time of each proton bunch with respect to the LHC bunch clock. The extreme versatility of the board also allowed the LHCb experiment to build a high-speed and high-sensitivity readout system for a fast background monitor based on a pair of plastic scintillators. The board has demonstrated very good performance and proved to be conceptually valid during the first months of operations at the LHC. Connected to the beam pickups, it provides the LHCb experiment with a real-time measurement of the total intensity of each bea...

  10. Two-dimensional beam-profile monitor using the Reticon MC510A array camera

    International Nuclear Information System (INIS)

    A quantitative two-dimensional beam profile may be obtained from a scintillator viewed by a Reticon camera which uses a 32 x 32 array of photodiodes as its sensing element. In this note, CAMAC-oriented data acquisition electronics which allow one either to transmit the profile to a computer, or to use the monitor in a stand-alone mode are described

  11. FEL beam qualities and application researches at the FELI

    International Nuclear Information System (INIS)

    The FELI four FEL facilities (FEL-1, FEL-2, FEL-3 and FEL-4) are open for users to supply several MW-level FELs covering a wide wavelength range from 278 nm to 40 μm. The ultraviolet (UV)- and visible-FEL facility (FEL-3) keeps the world record for the shortest wavelength oscillation of linac-based FELs with a thermionic gun since 1995. Technical challenges have been tried at simultaneous FEL beam sharing with fan-shaped mirrors for multistations including two manipulators and at FEL beam diagnostics of micropulse length and beam profile. The latter is for the evaluations of FEL peak power densities at irradiated spots. FEL peak power densities and adequate wavelengths are evaluated at thirteen research subjects performed at the FELI. The application researches have been performed distributed in a wide field of material science, chemical technology and bio-medical applications. (Copyright (c) 1998 Elsevier Science B.V., Amsterdam. All rights reserved.)

  12. Review of Surface Roughness Effect on Beam Quality

    Science.gov (United States)

    Mostacci, A.; Palumbo, L.; Alesini, D.

    2003-12-01

    In recent years a strong attention arose around the problem of the e.m. interaction of an ultra-relativistic beam with the residual roughness inside a beam tube, in particular in the framework of future 4th generation coherent light sources. The main concern was the effect of the wake-fields on the relative energy spread of the beam which has to be of the order of 10-4, as for example in the LCLS and TESLA case. Although the real roughness has a stochastic feature, most studies dealt with periodic structure, or dielectric-equivalent layer which are considered to be conservative with respect the stochastic case. In this paper we will review the main theoretical models, and the most significant measurements trying to provide to the reader a complete picture of the present status of understanding.

  13. Beam intensity and dose monitor system for heavy-ion tumor therapy

    International Nuclear Information System (INIS)

    The clinical trials of tumor therapy using heavy ion beams, supplied by the cooler storage ring of the Heavy Ion Research Facility in Lanzhou (HIRFL-CSR) with the energy of 100 to 450 MeV/u, are now in progress at the Institute of Modern Physics in Lanzhou. A beam intensity and dose monitor system has been developed to real-time monitor the irradiation dose and beam intensity stability and to make sure the safety of the patients. It is composed of integral ionization chamber, current-frequency transfer electric board and LabVIEW data acquiring and analyzing system. The measurements of this system show that it can work well under the clinical condition. (authors)

  14. Distributed beam loss monitor based on the Cherenkov effect in an optical fiber

    Science.gov (United States)

    Maltseva, Yu; Emanov, F. A.; Petrenko, A. V.; Prisekin, V. G.

    2015-05-01

    This review discusses a distributed beam loss monitor which is based on the Cherenkov effect in an optical fiber and which has been installed at the VEPP-5 Injection Complex at the Budker Institute of Nuclear Physics. The principle of the device operation consists in detecting the Cherenkov radiation generated in an optical fiber by relativistic charged particles that are produced in an electromagnetic shower when highly relativistic beam particles (electrons or positrons) hit the accelerator vacuum chamber wall. Our experiments used a photomultiplier tube (PMT) to detect the Cherenkov light. Knowing when the PMT signal arrives tells us where the beam loss occurs. Using a 20-m-long optical fiber allowed a detector spatial resolution of 3 m. The way to improve the resolution is to optimize the monitor working conditions and optical fiber and PMT parameters, potentially leading to a resolution of as fine as 0.5 m according to our estimates.

  15. A System for Monitoring and Tracking the LHC Beam Spot within the ATLAS High Level Trigger

    CERN Document Server

    Bartoldus, R; The ATLAS collaboration; Cogan, J; Salnikov, A; Strauss, E; Winklmeier, F

    2012-01-01

    The parameters of the beam spot produced by the LHC in the ATLAS interaction region are computed online using the ATLAS High Level Trigger (HLT) system. The high rate of triggered events is exploited to make precise measurements of the position, size and orientation of the luminous region in near real-time, as these parameters change significantly even during a single data-taking run. We present the challenges, solutions and results for the online determination, monitoring and beam spot feedback system in ATLAS. A specially designed algorithm, which uses tracks registered in the silicon detectors to reconstruct event vertices, is executed on the HLT processor farm of several thousand CPU cores. Monitoring histograms from all the cores are sampled and aggregated across the farm every 60 seconds. The reconstructed beam values are corrected for detector resolution effects, measured in situ from the separation of vertices whose tracks have been split into two collections. Furthermore, measurements for individual ...

  16. Monitoring and Tracking the LHC Beam Spot within the ATLAS High Level Trigger

    CERN Document Server

    Winklmeier, F; The ATLAS collaboration

    2012-01-01

    The parameters of the beam spot produced by the LHC in the ATLAS interaction region are computed online using the ATLAS High Level Trigger (HLT) system. The high rate of triggered events is exploited to make precise measurements of the position, size and orientation of the luminous region in near real-time, as these parameters change significantly even during a single data-taking run. We present the challenges, solutions and results for the online determination, monitoring and beam spot feedback system in ATLAS. A specially designed algorithm, which uses tracks registered in the silicon detectors to reconstruct event vertices, is executed on the HLT processor farm of several thousand CPU cores. Monitoring histograms from all the cores are sampled and aggregated across the farm every 60 seconds. The reconstructed beam values are corrected for detector resolution effects, measured in situ from the separation of vertices whose tracks have been split into two collections. Furthermore, measurements for individual ...

  17. Diamond pixel detector for beam profile monitoring in COMET experiment at J-PARC

    CERN Document Server

    Cerv, M; Pernegger, H; Vageesvaran, P; Griesmayer, E

    2015-01-01

    We present the design and initial prototype results of a pixellized proton beam profile monitor for the COMET experiment at J-PARC. The goal of COMET is to look for charged lepton flavor violation by direct muon to electron conversion at a sensitivity of $0^{-19}$. An 8 GeV proton beam pulsed at 100 ns with $10^{10}$ protons/s will be used to create muons through pion production and decay. In the final experiment, the proton flux will be raised to $10^{14}$ protons/sec to increase the sensitivity. These requirements of harsh radiation tolerance and fast readout make diamond a good choice for constructing a beam profile monitor in COMET. We present first results of the characterization of single crystal diamond (scCVD) sourced from a new company, 2a systems Singapore. Our measurements indicate excellent charge collection efficiency and high carrier mobility down to cryogenic temperatures.

  18. Capacitive large-range-intensity beam-position monitors at Ganil

    International Nuclear Information System (INIS)

    At GANIL, to allow a permanent measurement of the ion beam position, we are designing a non-interceptive beam position monitor. After having given the technical specifications - in particular a large intensity range 60dB - this paper describes the technical choices of made after theoretical studies: - capacitive electrodes loaded by 50 Ω amplifier, - 10 KHz heterodyne to detect the 2nd harmonic of the electrode signals, - amplitude-to-phase conversion followed by a phasemeter to detect the beam position. At the end of this paper, the first results obtained with a prototype monitor are given, in particular their good accordance with the theoretical calculation and the few problems still to solve

  19. Design and commissioning of the APS beam charge and current monitor

    International Nuclear Information System (INIS)

    The non-intercepting charge and current monitors suitable for a wide range of beam parameters have been developed and installed in the Advanced Photon Source (APS) low energy transport lines, positron accumulator ring (PAR), and injector synchrotron. The positron or electron beam pulse in the APS has charge ranging from 100pC to l0nC with pulse width varying from 30ps to 30ns. The beam charge and current are measured with a current transformer and subsequent current monitoring electronics based on an ultrafast, high precision gated integrator. The signal processing electronics, data acquisition, and communication with the control system are managed by a VME-based system. This paper summarizes the hardware and software features of the systems. The results of recent operations are presented

  20. Ribbon target assembly using carbon graphite for secondary emission type beam profile monitor

    International Nuclear Information System (INIS)

    We developed a secondary emission type beam profile monitor with graphite ribbons as a beam target. The graphite is excellent in endurance against heat load, and that they are thin as 1.6-2.0 micron and low z (=6) is advantage for reducing beam loss. Furthermore, since ribbons emits larger amount of electrons than ordinal metal wires because of larger surface, the monitor has higher sensitivity. On the other hands, in case of multi-ribbon type, uniformity of secondary electron emission is required for accurate measurement. For the uniform emission, not only surface homogeneity, but also evenness for each ribbon width is needed. A suitable manufacturing method to make ribbon target from graphite-foil, and emission uniformity has been studied. (author)

  1. Caenorhabditis elegans: a model to monitor bacterial air quality

    Directory of Open Access Journals (Sweden)

    Duclairoir Poc Cécile

    2011-11-01

    Full Text Available Abstract Background Low environmental air quality is a significant cause of mortality and morbidity and this question is now emerging as a main concern of governmental authorities. Airborne pollution results from the combination of chemicals, fine particles, and micro-organisms quantitatively or qualitatively dangerous for health or for the environment. Increasing regulations and limitations for outdoor air quality have been decreed in regards to chemicals and particles contrary to micro-organisms. Indeed, pertinent and reliable tests to evaluate this biohazard are scarce. In this work, our purpose was to evaluate the Caenorhaditis elegans killing test, a model considered as an equivalent to the mouse acute toxicity test in pharmaceutical industry, in order to monitor air bacterial quality. Findings The present study investigates the bacterial population in dust clouds generated during crop ship loading in harbor installations (Rouen harbor, Normandy, France. With a biocollector, airborne bacteria were impacted onto the surface of agar medium. After incubation, a replicate of the colonies on a fresh agar medium was done using a velvet. All the replicated colonies were pooled creating the "Total Air Sample". Meanwhile, all the colonies on the original plate were isolated. Among which, five representative bacterial strains were chosen. The virulence of these representatives was compared to that of the "Total Air Sample" using the Caenorhaditis elegans killing test. The survival kinetic of nematodes fed with the "Total Air Sample" is consistent with the kinetics obtained using the five different representatives strains. Conclusions Bacterial air quality can now be monitored in a one shot test using the Caenorhaditis elegans killing test.

  2. Data quality control in eco-environmental monitoring

    Science.gov (United States)

    Lu, Chunyan; Wang, Jing

    2007-11-01

    With the development of science and technology, a number of environmental issues, such as sustainable development, climate change, environmental pollution, and land degradation become serious. Greater attention has been attached to environmental protection. The government gradually launched some eco--environmental construction projects. In 1999, China begin to carry out the project of Grain-for-Green in the west, to improve the eco-environment, and it make some good effect, but there are some questions that still can not be answered. How about the new grass or forest? Where are they? How can we do in the future? To answer these questions, the government began to monitor the eco-environment, based on remote sensing technology. Geography information can be attained timely, but the issue of uncertainty has become increasingly recognized, and this uncertainty affects the reliability of applications using the data. This article analyzed the process of eco-environment monitoring, the uncertainty of geography information, and discussed the methods of data quality control. The Spot5 span data and multi-spectral data in 2003(2002) were used, combined with land use survey data at the scale of 1:10,000, topography data at the scale of 1:10,000, and the local Grain-for-Green project map. Also the social and economic data were collected. Eco-environmental monitoring is a process which consists of several steps, such as image geometric correction, image matching, information extraction, and so on. Based on visual and automated method, land information turned to grass and forest from cultivated land was obtained by comparing the information form remote sensing data with the land survey data, and local Grain-for-Green project data, combined with field survey. According to the process, the uncertainty in the process was analyzed. Positional uncertainty, attribute uncertainty, and thematic uncertainty was obvious. Positional uncertainty mainly derived from image geometric correction

  3. Groundwater monitoring: Guidelines and methodology for developing and implementing a ground-water quality monitoring program

    Energy Technology Data Exchange (ETDEWEB)

    Everett, L.G.

    1984-01-01

    The handbook attempts to structure a cost-effective, generic groundwater pollution monitoring methodology that can be applied either on a regional basis or to site-specific, alternative approaches to monitoring the quality of groundwater at a considerable saving of time and money. Extensive detail is given to the relation of groundwater quality to the geohydrologic framework, constituents in the polluted groundwater, sources and causes of pollution, and use of water. Information is also given about groundwater monitoring techniques used in top soil, the vadose zone, ad the saturated zone. The costs of these techniques are described in figures and tables. Groundwater databases and their applicability to water resources information systems are also covered. Comprehensive site-specific examples are given of how to use the material in the handbook to monitoring major sources of groundwater pollution. Included are in-depth models of hazardous waste disposal, brine disposal, landfill leachate control, oxidation ponds and percolation ponds, septic fields, and agricultural return flow, as well as descriptions of cases of multiple-source municipal and agricultural pollution.

  4. Beam Quality Preservation in the CERN PS-SPS Complex

    CERN Document Server

    Arduini, Gianluigi

    2004-01-01

    The LHC will require beams of unprecedented transverse and longitudinal brightness. Their production imposes tight constraints on the emittance growth in each element of the LHC injector chain, namely the PS-SPS Accelerator Complex. The problems encountered at the different stages of the acceleration in the complex span a wide range of topics, such as injection matching, RF gymnastics, space charge, transverse and longitudinal single- and coupled-bunch instabilities, and electron cloud effects. The measurement techniques developed and applied to identify and study the various sources of emittance dilution to the high precision required for the LHC beams and the solutions found to control such phenomena are illustrated.

  5. Improvement of spatial beam quality of laser sources with an intracavity Bragg grating

    OpenAIRE

    Yiou, Sylvie; Balembois, François; Georges, Patrick; Huignard, Jean-Pierre

    2003-01-01

    International audience We demonstrate a novel method for improvement of spatial beam quality by use of the angular selectivity of a thick phase grating inserted into various laser cavities. Preliminary experiments with an intentionally degraded beam from a Nd:YVO4 laser have enhanced beam propagation factor M2 by a factor of 4.5. Operation with a broad-area laser diode in an external cavity with a thick grating was achieved. We obtained 100 mW of cw power in a beam with an M2 of 1.3. Moreo...

  6. Metric for the measurement of the quality of complex beams: a theoretical study.

    Science.gov (United States)

    Kaim, Sergiy; Lumeau, Julien; Smirnov, Vadim; Zeldovich, Boris; Glebov, Leonid

    2015-04-01

    We present a theoretical study of various definitions of laser beam width in a given cross section. Quality of the beam is characterized by dimensionless beam propagation products (BPPs) Δx·Δθ(x)/λ, which are different for the 21 definitions presented, but are close to 1. Six particular beams are studied in detail. In the process, we had to review the properties for the Fourier transform of various modifications and the relationships between them: physical Fourier transform (PFT), mathematical Fourier transform (MFT), and discrete Fourier transform (DFT). We found an axially symmetric self-MFT function, which may be useful for descriptions of diffraction-quality beams. In the appendices, we illustrate the thesis "the Fourier transform lives on the singularities of the original." PMID:26366763

  7. Dosimetric characteristics of linear accelerator photon beams with small monitor unit settings.

    Science.gov (United States)

    Kang, Sei-Kwon; Cheong, Kwang-Ho; Hwang, Taejin; Cho, Byung Chul; Kim, Su Ssan; Kim, Kyoung Ju; Oh, Do Hoon; Bae, Hoonsik; Suh, Tae-Suk

    2008-11-01

    Several studies on the effect of tumor cell killing by dose rate variation have implied that the use of a shorter treatment time is more favorable for intensity modulated radiation therapy (IMRT). Aiming at step-and-shoot IMRT with higher dose rates, the stabilities of beam output and profiles with small monitor unit (MU) settings were investigated for various dose rates. With the use of a Varian 21EX (Varian Medical Systems Inc., Palo Alto, CA), static and step-and-shoot IMRT beam output along with profiles were measured by use of an ion chamber and a two-dimensional diode array detector as a function of monitor units and dose rates. For a static case, as the MU approached 1, the beam output increased up to 2% for 300 MU/min and 4.5% for 600 MU/min, showing a larger overdose as the dose rate increased. Deterioration of the beam symmetry and flatness were also observed as the MU decreased to 1 monitor unit. For the step-and-shoot IMRT case, a large dosimetric error of more than 10% was also detected with the use of a small MU segment. However, no definite correlation with the dose rate was observed due to the combined beam start-up effects by the grid pulse and finite communication time between the machine console and multileaf collimator (MLC) controller. For step-and-shoot IMRT with higher dose rates, beam output and beam profile stability with small MU needs to be checked, and adequate MU limitation where segments are not allowed need to be reflected in the step-and-shoot IMRT planning. PMID:19070251

  8. Beam-quality measurements on heavy ion therapeutic beam of HIMAC

    International Nuclear Information System (INIS)

    Fluence spectra of fragment particles caused by spallation reactions between heavy ion beams and PMMA (polymethyl methacrylate; Lucite) target were measured with ΔE-E counter telescope method for each fragmented element. Measurements were carried out for carbon beams of 290 MeV/nucleon and 400 MeV/nucleon at Heavy Ion Medical Accelerator in Chiba (HIMAC), and 135 MeV/nucleon carbon beam at RIKEN Ring Cyclotron with changing the thickness of target material. Incident beam was broadened with a pair of wobbler magnets and a scatterer, in the same way of clinical trials which have been carrying out at HIMAC. Results were compared with the calculational expectations. (author)

  9. GATE simulation based feasibility studies of in-beam PET monitoring in 12C beam cancer therapy

    Institute of Scientific and Technical Information of China (English)

    WU Jing; LIU Yaqiang; MA Tianyu; WEI Qingyang; WANG Shi; CHENG Jianping

    2010-01-01

    In comparison with conventional radiotherapy techniques,12C beam therapy has its significant advantage in cancer treatment because the radiation dose are mostly concentrated near the Bragg peak region and damage to normal tissues along the beam path is thus greatly reduced.In-beam PET provides a way to monitor dose distribution inside human body since several kinds of positron-emitting nuclei are produced through the interaction between 12C beam and body matters.In this work,we study the quantitative relationship between the spatial location of the Bragg peak and the spatial distribution of positrons produced by positron-emitting nuclei.Monte Carlo package GATE is used to simulate the interactions between the incident 12C beam of different energies (337.5,270.0 and 195.0 MeV/u) and various target matters (water,muscle and spine bone).Several data post-processing operations are performed on the simulated positron-emitting nuclei distribution data to mimic the impacts of positron generation and finite spatial resolution of a typical PET imaging system.Simulation results are compared to published experimental data for verification.In all the simulation cases,we fred that 10C and 11C are two dominant positron-emitting nuclei,and there exists a significant correlation between the spatial distributions of deposited energy and positrons.Therefore,we conclude that it is possible to determine the location of Bragg peak with 1 mm accuracy using current PET imaging systems by detecting the falling edge of the positron distribution map in depth direction.

  10. GATE simulation based feasibility studies of in-beam PET monitoring in 12C beam cancer therapy

    International Nuclear Information System (INIS)

    In comparison with conventional radiotherapy techniques, 12C beam therapy has its significant advantage in cancer treatment because the radiation dose are mostly concentrated near the Bragg peak region and damage to normal tissues along the beam path is thus greatly reduced. In-beam PET provides a way to monitor dose distribution inside human body since several kinds of positron-emitting nuclei are produced through the interaction between 12C beam and body matters. In this work, we study the quantitative relationship between the spatial location of the Bragg peak and the spatial distribution of positrons produced by positron-emitting nuclei. Monte Carlo package GATE is used to simulate the interactions between the incident 12C beam of different energies (337.5, 270.0 and 195.0 MeV/u) and various target matters (water, muscle and spine bone). Several data post-processing operations are performed on the simulated positron-emitting nuclei distribution data to mimic the impacts of positron generation and finite spatial resolution of a typical PET imaging system. Simulation results are compared to published experimental data for verification. In all the simulation cases, we find that 10C and 11C are two dominant positron-emitting nuclei, and there exists a significant correlation between the spatial distributions of deposited energy and positrons. Therefore, we conclude that it is possible to determine the location of Bragg peak with 1 mm accuracy using current PET imaging systems by detecting the falling edge of the positron distribution map in depth direction. (authors)

  11. Construction of the beam profile monitor system with CameraLink in the SPring-8 booster ring and beam transport line

    International Nuclear Information System (INIS)

    We had measured the beam position and size in the SPring-8 booster ring and beam transport line by the monitor system that consists of analog video camera and fluorescent plate. It was difficult to estimate the seasonal change of the beam position and beam size between user operation cycles. In order to keep the high injection efficiency to SPring-8 storage ring, we need to achieve the tuning reproducibility of the accelerator parameter in the booster ring and beam transport line by using the quantitative data. The newly constructed beam profile monitor system consists of the digital CCD camera with external trigger synchronous capturing function, camera selectors, and server computers. Each camera system placed on the booster ring and beam transport line are managed by the UNIX server computer setup for each area. This system is connected by the cameralink configuration devices with cameralink cables or optical fiber cables. It became possible to capture image of beam profile synchronous with a beam trigger with a high resolution and a fast capturing time as same as it by using the analog video system. We will report the detail of beam profile monitor system with cameralink and the system operation. (author)

  12. Quality Assurance in Individual Monitoring: 10 Years of Performance Monitoring of the TLD Based TNO Individual Monitoring Service (invited paper)

    International Nuclear Information System (INIS)

    The QA subscription forms the nucleus of the Quality Assurance (QA) programme of the TLD-based Individual Monitoring Service of TNO-CSD. This QA subscription is the subscription of a dummy customer to the service. As this customer is treated exactly like a normal customer, all aspects of the service are monitored by the QA subscription. An overview is given of 10 years of monitoring the performance of the service. Various improvements over the past decade have resulted in a standard deviation in a low dose measurement of 0.01 mSv and a relative standard deviation at higher doses of 5%. These figures represent the performance under routine circumstances and thus include variations due to variations in the natural background from place to place and, for example, due to transport. (author)

  13. On-line neutron beam monitoring of the Finnish BNCT facility

    International Nuclear Information System (INIS)

    A Boron Neutron Capture Therapy (BNCT) facility has been built at the FiR 1 research reactor of VTT Chemical Technology in Espoo, Finland. The facility is currently undergoing dosimetry characterisation and neutron beam operation research for clinical trials. The healthy tissue tolerance study, which was carried out in the new facility during spring 1998, demonstrated the reliability and user-friendliness of the new on-line beam monitoring system designed and constructed for BNCT by VTT Chemical Technology. The epithermal neutron beam is monitored at a bismuth gamma shield after an aluminiumfluoride-aluminium moderator. The detectors are three pulse mode U235-fission chambers for epithermal neutron fluence rate and one current mode ionisation chamber for gamma dose rate. By using different detector sensitivities the beam intensity can be measured over a wide range of reactor power levels (0.001-250 kW). The detector signals are monitored on-line with a virtual instrumentation (LabView) based PC-program, which records and displays the actual count rates and total counts of the detectors in the beam. Also reactor in-core power instrumentation and control rod positions can be monitored via another LabView application. The main purpose of the monitoring system is to provide a dosimetric link to the dose in a patient during the treatment, as the fission chamber count rates have been calibrated to the induced thermal neutron fluence rate and to the absorbed dose rate at reference conditions in a tissue substitute phantom

  14. On-line neutron beam monitoring of the Finnish BNCT facility

    Science.gov (United States)

    Tanner, Vesa; Auterinen, Iiro; Helin, Jori; Kosunen, Antti; Savolainen, Sauli

    1999-02-01

    A Boron Neutron Capture Therapy (BNCT) facility has been built at the FiR 1 research reactor of VTT Chemical Technology in Espoo, Finland. The facility is currently undergoing dosimetry characterisation and neutron beam operation research for clinical trials. The healthy tissue tolerance study, which was carried out in the new facility during spring 1998, demonstrated the reliability and user-friendliness of the new on-line beam monitoring system designed and constructed for BNCT by VTT Chemical Technology. The epithermal neutron beam is monitored at a bismuth gamma shield after an aluminiumfluoride-aluminium moderator. The detectors are three pulse mode U 235-fission chambers for epithermal neutron fluence rate and one current mode ionisation chamber for gamma dose rate. By using different detector sensitivities the beam intensity can be measured over a wide range of reactor power levels (0.001-250 kW). The detector signals are monitored on-line with a virtual instrumentation (LabView) based PC-program, which records and displays the actual count rates and total counts of the detectors in the beam. Also reactor in-core power instrumentation and control rod positions can be monitored via another LabView application. The main purpose of the monitoring system is to provide a dosimetric link to the dose in a patient during the treatment, as the fission chamber count rates have been calibrated to the induced thermal neutron fluence rate and to the absorbed dose rate at reference conditions in a tissue substitute phantom.

  15. Adaptive slab laser beam quality improvement using a weighted least-squares reconstruction algorithm.

    Science.gov (United States)

    Chen, Shanqiu; Dong, LiZhi; Chen, XiaoJun; Tan, Yi; Liu, Wenjin; Wang, Shuai; Yang, Ping; Xu, Bing; Ye, YuTang

    2016-04-10

    Adaptive optics is an important technology for improving beam quality in solid-state slab lasers. However, there are uncorrectable aberrations in partial areas of the beam. In the criterion of the conventional least-squares reconstruction method, it makes the zones with small aberrations nonsensitive and hinders this zone from being further corrected. In this paper, a weighted least-squares reconstruction method is proposed to improve the relative sensitivity of zones with small aberrations and to further improve beam quality. Relatively small weights are applied to the zones with large residual aberrations. Comparisons of results show that peak intensity in the far field improved from 1242 analog digital units (ADU) to 2248 ADU, and beam quality β improved from 2.5 to 2.0. This indicates the weighted least-squares method has better performance than the least-squares reconstruction method when there are large zonal uncorrectable aberrations in the slab laser system. PMID:27139877

  16. Test Results on the Silicon Pixel Detector for the TTF-FEL Beam Trajectory Monitor

    CERN Document Server

    Hillert, S; Müller, U C; Roth, S; Hansen, K; Holl, P; Karstensen, S; Kemmer, J; Klanner, Robert; Lechner, P; Leenen, M; Ng, J S T; Schmüser, P; Strüder, L

    2001-01-01

    Test measurements on the silicon pixel detector for the beam trajectory monitor at the free electron laser of the TESLA test facility are presented. To determine the electronic noise of detector and read-out and to calibrate the signal amplitude of different pixels the 6 keV photons of the manganese K line are used. Two different methods determine the spatial accuracy of the detector: In one setup a laser beam is focused to a straight line and moved across the pixel structure. In the other the detector is scanned using a low-intensity electron beam of an electron microscope. Both methods show that the symmetry axis of the detector defines a straight line within 0.4 microns. The sensitivity of the detector to low energy X-rays is measured using a vacuum ultraviolet beam at the synchrotron light source HASYLAB. Additionally, the electron microscope is used to study the radiation hardness of the detector.

  17. Electromagnetic Coupling Between High Intensity LHC Beams and the Synchrotron Radiation Monitor Light Extraction System

    CERN Document Server

    Andreazza, W; Bravin, E; Caspers, F; Garlasch`e, M; Gras, J; Goldblatt, A; Lefevre, T; Jones, R; Metral, E; Nosych, A; Roncarolo_, F; Salvant, B; Trad, G; Veness, R; Vollinger, C; Wendt, M

    2013-01-01

    The CERN LHC is equipped with two Synchrotron Radiation Monitor (BSRT) systems used to characterise transverse and longitudinal beam distributions. Since the end of the 2011 LHC run the light extraction system, based on a retractable mirror, has suffered deformation and mechanical failure that is correlated to the increase in beam intensity. Temperature probes have associated these observations to a strong heating of the mirror support with a dependence on the longitudinal bunch length and shape, indicating the origin as electromagnetic coupling between the beam and the structure. This paper combines all this information with the aim of characterising and improving the system in view of its upgrade during the current LHC shutdown. Beam-based observations are presented along with electromagnetic and thermomechanical simulations and complemented by laboratory measurements, including the study of the RF properties of different mirror bulk and coating materials.

  18. Combining tissue-phantom ratios to provide a beam-quality specifier for flattening filter free photon beams

    Energy Technology Data Exchange (ETDEWEB)

    Dalaryd, Mårten, E-mail: Marten.Dalaryd@med.lu.se; Knöös, Tommy [Department of Clinical Sciences, Medical Radiation Physics, Lund University, P.O. Box 117, Lund SE-221 00, Sweden and Radiation Physics, Skåne University Hospital, Lund SE-221 85 (Sweden); Ceberg, Crister [Department of Clinical Sciences, Medical Radiation Physics, Lund University, P.O. Box 117, Lund SE-221 00 (Sweden)

    2014-11-01

    Purpose: There are currently several commercially available radiotherapy treatment units without a flattening filter in the beam line. Unflattened photon beams have an energy and lateral fluence distribution that is different from conventional beams and, thus, their attenuation properties differ. As a consequence, for flattening filter free (FFF) beams, the relationship between the beam-quality specifier TPR{sub 20,10} and the Spencer–Attix restricted water-to-air mass collision stopping-power ratios, (L{sup -}/ρ){sub air}{sup water}, may have to be refined in order to be used with equivalent accuracy as for beams with a flattening filter. The purpose of this work was twofold. First, to study the relationship between TPR{sub 20,10} and (L{sup -}/ρ){sub air}{sup water} for FFF beams, where the flattening filter has been replaced by a metal plate as in most clinical FFF beams. Second, to investigate the potential of increasing the accuracy in determining (L{sup -}/ρ){sub air}{sup water} by adding another beam-quality metric, TPR{sub 10,5}. The relationship between (L{sup -}/ρ){sub air}{sup water} and %dd(10){sub x} for beams with and without a flattening filter was also included in this study. Methods: A total of 24 realistic photon beams (10 with and 14 without a flattening filter) from three different treatment units have been used to calculate (L{sup -}/ρ){sub air}{sup water}, TPR{sub 20,10}, and TPR{sub 10,5} using the EGSnrc Monte Carlo package. The relationship between (L{sup -}/ρ){sub air}{sup water} and the dual beam-quality specifier TPR{sub 20,10} and TPR{sub 10,5} was described by a simple bilinear equation. The relationship between the photon beam-quality specifier %dd(10){sub x} used in the AAPM’s TG-51 dosimetry protocol and (L{sup -}/ρ){sub air}{sup water} was also investigated for the beams used in this study, by calculating the photon component of the percentage depth dose at 10 cm depth with SSD 100 cm. Results: The calculated (L{sup -}/

  19. A Four Channel Beam Current Monitor Data Acquisition System Using Embedded Processors

    Energy Technology Data Exchange (ETDEWEB)

    Wheat, Jr., Robert Mitchell [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dalmas, Dale A. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dale, Gregory E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-08-11

    Data acquisition from multiple beam current monitors is required for electron accelerator production of Mo-99. A two channel system capable of recording data from two beam current monitors has been developed, is currently in use, and is discussed below. The development of a cost-effective method of extending this system to more than two channels and integrating of these measurements into an accelerator control system is the main focus of this report. Data from these current monitors is digitized, processed, and stored by a digital data acquisition system. Limitations and drawbacks with the currently deployed digital data acquisition system have been identified as have been potential solutions, or at least improvements, to these problems. This report will discuss and document the efforts we've made in improving the flexibility and lowering the cost of the data acquisition system while maintaining the minimum requirements.

  20. Beam loss monitor system of the rapid cycling synchrotron of Japan Proton Accelerator Research Complex

    International Nuclear Information System (INIS)

    The 3 GeV Rapid Cycling Synchrotron (RCS) of the Japan Proton Accelerator Research Complex (J-PARC) provides more than 300 kW beam to the Material and Life Science Facility (MLF) and the Main Ring (MR). In such high intensity hadron accelerator, the lost protons that are a fraction of the beam less than 0.1% cause many problems. Those particles bring about a serious radioactivation and a malfunction of the accelerator components. Therefore, the beam loss monitor (BLM) is one of the most important equipment to observe the state of the beam during operation, and to keep a steady operation. Moreover, if we set operation parameters of BLM adequately, it can detect the beam loss that is 10-6 fraction of the beam. Thus it enables fine-tuning of the accelerator. In the J-PARC RCS, a proportional counter and a plastic scintillation counter are used for the beam commission and the stable operation as BLM. We report present status of the BLM system in J-PARC RCS. (author)