  1. Can Neutron Beam Components and Radiographic Image Quality be determined by the Use of Beam Purity and Sensitivity Indicators?

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1986-01-01

    radiography f a c i l i t i e s of the European Community. The direct, transfer and track-etch methods using different f i lm recording materials were used. Neutron beam components were calculated from film density measurements under the beam purity indicators and radiographic image quality was assessed......In the Euratom Neutron Radiography Working Group Test Program beam purity and s e n s i t i v i t y indicators, as prescribed by the ASTM E 545-81 were used together with the NRWG beam purity i n d i c a t o r - f u e l and c a l i b r a t i o n fuel pin. They were radiographed together at neutron...

  2. Quality indicators

    DEFF Research Database (Denmark)

    Hjorth-Andersen, Christian

    1991-01-01

    In recent literature it has been suggested that consumers need have no knowledge of product quality as a number of quality indicators (or signals) may be used as substitutes. Very little attention has been paid to the empirical verification of these studies. The present paper is devoted...... to the issue of how well these indicators perform, using market data provided by consumer magazines from 3 countries. The results strongly indicate that price is a poor quality indicator. The paper also presents some evidence which suggests that seller reputation and easily observable characteristics are also...

  3. Verification of dose output and beam quality indicator in linear accelerators; Verificacao do fator de calibracao e indicador de qualidade do feixe de aceleradores lineares

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Maria da Penha [Instituto Nacional do Cancer, Rio de Janeiro, RJ (Brazil)]. E-mail: mpenhas@hotmail.com; Mota, Helvecio Correa [Instituto de Radioprotecao e Dosimetria (IRD), Rio de Janeiro, RJ (Brazil); Almeida, Carlos Eduardo V. de [Universidade do Estado, Rio de Janeiro, RJ (Brazil). Lab. de Ciencias Radiologicas

    2001-10-01

    A quality assurance program is a mandatory prerequisite for obtaining the high level of accuracy required for radiotherapy. This paper reports the results of part of the routine quality control tests for linear accelerators at the National Cancer Institute, Brazil, performed monthly over a period of two years. These tests included dose output and beam quality indicator. The results were compared with the guidelines of the AAPM TG-40 protocol. The results for the photon beams have shown dose output variations of up to 12%; for electron beams, the largest deviation found was 10%. The fluctuations observed in the beam quality indicator for the electron beams were greater than for the photon beams. These results strongly emphasize the importance of a quality assurance program in radiotherapy services in order to allow prompt corrections of the dose delivered to the patient. (author)

  4. Quality indicators in radiotherapy

    International Nuclear Information System (INIS)

    Cionini, Luca; Gardani, Gianstefano; Gabriele, Pietro; Magri, Secondo; Morosini, Pier Luigi; Rosi, Antonella; Viti, Vincenza

    2007-01-01

    Background and purpose: There is a widespread and increasing tendency to develop hospital performance indicators in the field of accreditation/certification systems and quality benchmarking. A study has been undertaken to develop a set of performance indicators for a typical radiotherapy Centre and to evaluate their ability to provide a continuous quality improvement. Materials and methods: A working group consisting of radiation oncologists, medical physicists and radiation technologists under the coordination of experts in health technology assessment has elaborated a set of general indicators able to monitor performances and the quality level of a typical radiotherapy Centre. The work has been carried out through four steps: a preliminary set of indicators was selected; data on these indicators were collected in a number of Italian radiotherapy Centres and medical physics Services; problems in collection and analysis of data were discussed; a final set of indicators was developed. Results: A final set of 13 indicators is here presented. They concern general structural and/or operational features, health physics activities and accuracy and technical complexity of the treatment. Conclusions: The indicators tested in a few Italian Centres of radiotherapy and medical physics Services are now ready to be utilized by a larger community

  5. Air quality indicators

    International Nuclear Information System (INIS)

    Clench-Aas, Jocelyn; Guerreiro, Cristina; Bartonova, Alena

    1999-06-01

    This report proposes and describes in detail several air quality indicators that may be used to describe population exposure. The suggested indicators account for temporal and spatial patterns of pollution and movements of individuals between different micro-environments. The Air Quality Indicator /AQI) should represent both the spatial and temporal aspects of pollution exposure that may have important effects on health. Two indicators are needed, the Population Air Quality Indicator and the Individual Air Quality Indicator. Mean concentrations, 98th percentile and maximum values are the traditional indicators for estimating exposure. the temporal variability of PM-10 and NO 2 , however, is here described by means of: 1) The rate of change of pollution as the difference between two consecutive hourly values and of 2) episodes, described in terms of number, duration and winter episode period, maximum concentration in the episode and integrated episode exposure (episode AOT50/100). The spatial variation of AQIs can be described in several ways, e.g.: 1) Concentrations in neighbouring grid squares can be compared as an indication of spatial variation and 2) point estimates can be compared to grid values for a description of variation within a grid. Both methods are presented here. A test of the representativity of static point estimates for pollution exposure is to compare them to an estimate of air pollution exposure accounting for movements between different locations, obtained using diaries. The ultimate aim of AQIs is to describe the population exposure to ambient pollution. This is done by estimating the number of people exposed using different characteristics of AQIs. The data used to describe these indicators originates from dispersion modelling of short-term air pollution concentrations in Oslo. Two series of data are used. One represents hour-for hour concentrations in the 1 km 2 grid system covering the city of Oslo, winter 1994/95, calculated by the grid

  6. On beam quality and flatness of radiotherapy megavoltage photon beams

    International Nuclear Information System (INIS)

    Hossain, Murshed; Rhoades, Jeffrey

    2016-01-01

    Ratio of percentage depth dose (PDD) at two depths, PDD at a depth of 10 cm (PDD 10 ), and beam flatness are monitored regularly for radiotherapy beams for quality assurance. The purpose of this study is to understand the effects of changes in one of these parameters on the other. Is it possible to monitor only the beam flatness and not PDD? The investigation has two components. Naturally occurring i.e., unintended changes in PDD ratio and in-plane flatness for 6 and 10 MV photon beams for one particular Siemens Artiste Linac are monitored for a period of about 4 years. Secondly, deliberate changes in the beam parameters are induced by changing the bending magnet current (BMI). Relationships between various beam parameters for unintended changes as well as deliberate changes are characterized. Long term unintentional changes of PDD ratio are found to have no systematic trend. The flatness in the in plane direction for 6 and 10 MV beams show slow increase of 0.43 and 0.75 % respectively in about 4 years while the changes in the PDD ratio show no such trend. Over 10 % changes in BMI are required to induce changes in the beam quality indices at 2 % level. PDD ratio for the 10 MV beam is found to be less sensitive, while the depth of maximum dose, d max , is more sensitive to the changes in BMI compared to the 6 MV beam. Tolerances are more stringent for PDD 10 than PDD ratio for the 10 MV beam. PDD ratio, PDD 10 , and flatness must be monitored independently. Furthermore, off axis ratio alone cannot be used to monitor flatness. The effect of beam quality change in the absolute dose is clinically insignificant.

  7. A better beam quality

    CERN Multimedia

    CERN Bulletin

    2010-01-01

    Progress has been made on two fronts, providing physics data and preparing for higher intensities. Over the Whitsun weekend of May 22 to 24, 5 fills for physics provided almost 30 hours of stable colliding beams, all with bunch intensities around 2x1010 protons and at a β* of 2m. The first three of these fills were with 6 bunches per beam, giving 3 pairs of collisions in all experiments. For the other two fills, the number of bunches per beam was increased to 13, giving 8 pairs of colliding bunches, and for the first time luminosities were pushed above 1029 cm-2s-1, 2 orders of magnitude higher than first collisions in March. In between and after these physics fills, nominal bunches of 1011 protons were successfully ramped and brought into collision in ATLAS and CMS for the first time (not in stable beam conditions and without squeeze). Event rates seen by the experiments were in the expected range for these conditions. In the middle of this work, a short fill with beams of 7 nominal bunches was ...

  8. Quality Indicators for Learning Analytics

    Science.gov (United States)

    Scheffel, Maren; Drachsler, Hendrik; Stoyanov, Slavi; Specht, Marcus

    2014-01-01

    This article proposes a framework of quality indicators for learning analytics that aims to standardise the evaluation of learning analytics tools and to provide a mean to capture evidence for the impact of learning analytics on educational practices in a standardised manner. The criteria of the framework and its quality indicators are based on…

  9. Quality Indicators in Radiation Oncology

    International Nuclear Information System (INIS)

    Albert, Jeffrey M.; Das, Prajnan

    2013-01-01

    Oncologic specialty societies and multidisciplinary collaborative groups have dedicated considerable effort to developing evidence-based quality indicators (QIs) to facilitate quality improvement, accreditation, benchmarking, reimbursement, maintenance of certification, and regulatory reporting. In particular, the field of radiation oncology has a long history of organized quality assessment efforts and continues to work toward developing consensus quality standards in the face of continually evolving technologies and standards of care. This report provides a comprehensive review of the current state of quality assessment in radiation oncology. Specifically, this report highlights implications of the healthcare quality movement for radiation oncology and reviews existing efforts to define and measure quality in the field, with focus on dimensions of quality specific to radiation oncology within the “big picture” of oncologic quality assessment efforts

  10. Quality indicators for eye bank.

    Science.gov (United States)

    Acharya, Manisha; Biswas, Saurabh; Das, Animesh; Mathur, Umang; Dave, Abhishek; Singh, Ashok; Dubey, Suneeta

    2018-03-01

    The aim of this study is to identify quality indicators of the eye bank and validate their effectivity. Adverse reaction rate, discard rate, protocol deviation rate, and compliance rate were defined as Quality Indicators of the eye bank. These were identified based on definition of quality that captures two dimensions - "result quality" and "process quality." The indicators were measured and tracked as part of quality assurance (QA) program of the eye bank. Regular audits were performed to validate alignment of standard operating procedures (SOP) with regulatory and surgeon acceptance standards and alignment of activities performed in the eye bank with the SOP. Prospective study of the indicators was performed by comparing their observed values over the period 2011-2016. Adverse reaction rate decreased more than 8-fold (from 0.61% to 0.07%), discard rate decreased and stabilized at 30%, protocol deviation rate decreased from 1.05% to 0.08%, and compliance rate reported by annual quality audits improved from 59% to 96% at the same time. In effect, adverse reaction rate, discard rate, and protocol deviation rate were leading indicators, and compliance rate was the trailing indicator. These indicators fulfill an important gap in available literature on QA in eye banking. There are two ways in which these findings can be meaningful. First, eye banks which are new to quality measurement can adopt these indicators. Second, eye banks which are already deeply engaged in quality improvement can test these indicators in their eye bank, thereby incorporating them widely and improving them over time.

  11. Quality indicators for eye bank

    Directory of Open Access Journals (Sweden)

    Manisha Acharya

    2018-01-01

    Full Text Available Purpose: The aim of this study is to identify quality indicators of the eye bank and validate their effectivity. Methods: Adverse reaction rate, discard rate, protocol deviation rate, and compliance rate were defined as Quality Indicators of the eye bank. These were identified based on definition of quality that captures two dimensions – “result quality” and “process quality.” The indicators were measured and tracked as part of quality assurance (QA program of the eye bank. Regular audits were performed to validate alignment of standard operating procedures (SOP with regulatory and surgeon acceptance standards and alignment of activities performed in the eye bank with the SOP. Prospective study of the indicators was performed by comparing their observed values over the period 2011–2016. Results: Adverse reaction rate decreased more than 8-fold (from 0.61% to 0.07%, discard rate decreased and stabilized at 30%, protocol deviation rate decreased from 1.05% to 0.08%, and compliance rate reported by annual quality audits improved from 59% to 96% at the same time. In effect, adverse reaction rate, discard rate, and protocol deviation rate were leading indicators, and compliance rate was the trailing indicator. Conclusion: These indicators fulfill an important gap in available literature on QA in eye banking. There are two ways in which these findings can be meaningful. First, eye banks which are new to quality measurement can adopt these indicators. Second, eye banks which are already deeply engaged in quality improvement can test these indicators in their eye bank, thereby incorporating them widely and improving them over time.

  12. Website quality indicators for consumers.

    Science.gov (United States)

    Griffiths, Kathleen M; Christensen, Helen

    2005-11-15

    The rating tool DISCERN was designed for use by consumers without content expertise to evaluate the quality of health information. There is some evidence that DISCERN may be a valid indicator of evidence-based website quality when applied by health professionals. However, it is not known if the tool is a valid measure of evidence-based quality when used by consumers. Since it is a lengthy instrument requiring training in its use, DISCERN may prove impractical for use by the typical consumer. It is therefore important to explore the validity of other simpler potential indicators of site quality such as Google PageRank. This study aimed to determine (1) whether the instrument DISCERN is a valid indicator of evidence-based Web content quality for consumers without specific mental health training, and (2) whether Google PageRank is an indicator of website content quality as measured by an evidence-based gold standard. This was a cross-sectional survey of depression websites using consumer and health professional raters. The main outcome measures were (1) site characteristics, (2) evidence-based quality of content as measured by evidence-based depression guidelines, (3) DISCERN scores, (4) Google PageRank, and (5) user satisfaction. There was a significant association between evidence-based quality ratings and average DISCERN ratings both for consumers (r = 0.62, P = .001) and health professionals (r = 0.80, P PageRank (r = 0.59, P = .002). However, the correlation between DISCERN scores and user satisfaction was higher than the correlation between Google PageRank and user satisfaction. DISCERN has potential as an indicator of content quality when used either by experts or by consumers. Google PageRank shows some promise as an automatic indicator of quality.

  13. Verificação do fator de calibração e indicador da qualidade do feixe de aceleradores lineares Verification of dose output and beam quality indicator in linear accelerators

    Directory of Open Access Journals (Sweden)

    Maria da Penha Silva

    2001-10-01

    Full Text Available Um programa de garantia da qualidade é um pré-requisito obrigatório para a exatidão necessária em radioterapia. Este trabalho relata parte dos testes de rotina mensal do controle da qualidade dos aceleradores lineares do Instituto Nacional do Câncer, relativos à calibração dos feixes de fótons e elétrons, no período de dois anos. Os resultados foram comparados com as recomendações do protocolo AAPM TG-40. Na análise do fator de calibração para o feixe de fótons foi encontrado um desvio máximo de 12%; para o feixe de elétrons o maior desvio encontrado foi 10%. A flutuação observada no indicador da qualidade do feixe para os feixes de elétrons foi maior que para os feixes de fótons. Os resultados confirmam a importância de um programa de garantia da qualidade em um serviço de radioterapia, permitindo correções rápidas da dose administrada ao paciente.A quality assurance program is a mandatory prerequisite for obtaining the high level of accuracy required for radiotherapy. This paper reports the results of part of the routine quality control tests for linear accelerators at the National Cancer Institute, Brazil, performed monthly over a period of two years. These tests included dose output and beam quality indicator. The results were compared with the guidelines of the AAPM TG-40 protocol. The results for the photon beams have shown dose output variations of up to 12%; for electron beams, the largest deviation found was 10%. The fluctuations observed in the beam quality indicator for the electron beams were greater than for the photon beams. These results strongly emphasize the importance of a quality assurance program in radiotherapy services in order to allow prompt corrections of the dose delivered to the patient.

  14. In situ measurement of laser beam quality

    Science.gov (United States)

    Hashemi, Somayeh Sadat; Ghavami Sabouri, Saeed; Khorsandi, Alireza

    2017-09-01

    An innovative optical method is introduced for the beam quality measurement of any arbitrary transverse mode based on the reconstruction of the mode from a few-frame image of the beam cross-section. This is performed by the decomposition of a mode to its basic Hermite-Gaussian modal coefficients. The performance of the proposed method is examined through M 2-factor measurement of the beam of a Nd:YAG laser which was forced to oscillate in a certain mode using a crossed rectangular intracavity aperture. Obtained results have shown that this method can be alternatively replaced for the hologram- and ISO-based techniques recently exploiting for beam quality measurement regardless of the mode type and the position of utilized CCD camera along the beam direction.

  15. Price as indicator for quality?

    DEFF Research Database (Denmark)

    Nielsen, Jørgen Ulff-Møller; Hansen, Jørgen Drud

    This paper examines the relation between price differences and quality differences in an oligopoly model with intra-industry trade, where goods are horizontally as well as vertically differentiated. The analysis demonstrates that the ratio of prices is not linked to the ratio of qualities in any...

  16. Quality indicators for breast cancer

    DEFF Research Database (Denmark)

    Poortmans, Philip; Aznar, Marianne; Bartelink, Harry

    2012-01-01

    stimulated the development of quality assurance tools and guidelines, which are now applied in daily clinical practice. The new technical opportunities to optimize dose distributions in patients require dedicated quality assurance measures because they may be more sensitive to variations throughout...... cancer patients in terms of disease control, survival, and quality of life. This progress is based on clinical research and paralleled by progress in delivering sophisticated radiation treatment. Clinical trials resulted in identifying patients groups who will benefit from radiation treatment. They also...

  17. Air quality indices : a review

    International Nuclear Information System (INIS)

    Hewings, J.

    2001-10-01

    Pollution Probe presents some background information that will help in the development of a national Air Quality Index (AQI) in Canada. This report examines the issues that should be addressed in revising the national Index of the Quality of Air (IQUA) or creating a new national Air Quality Index. The IQUA was devised in 1976 and provides Canadians with real-time information on the state of community air quality by including major pollutants and their synergies. It is currently being used for air quality management plans and air quality alert systems. At the same time that the IQUA was devised, the United States Environmental Protection Agency (US EPA) produced a parallel air quality index known as the Pollution Standard Index (PSI) which incorporated 5 criteria pollutants (particulate matter, sulphur dioxide, carbon monoxide, nitrogen oxide and ground level ozone) for which national health-based standards were devised. In 1999, the US EPA renamed their index the Air Quality Index (AQI) and made revisions to the primary health-based national ambient air quality standards for ground-level ozone and particulate matter. Separate values for PM2.5 and PM10 were incorporated and mandatory reporting was required for metropolitan areas with populations of 350,000 or more. Similarly, the IQUA has undergone major developments that affect the validity of the index, including: rejection by the Working Group on Air Quality Objectives and Guidelines of the previous maximum desirable and maximum acceptable air quality criteria, recognition that standards for many of the contaminants are outdated, developing more sensitive instrumentation for real-time monitoring of contaminants. This report also describes the use of the national short term Air Quality Index by provincial, territorial and local authorities in Canada. Pollution Probe recommends setting up a mechanism to review and revise IQUA on a regular basis that would incorporate governments, the medical profession, special

  18. Bench calibration of INDUS-2 beam position indicators

    International Nuclear Information System (INIS)

    Tyagi, Y.; Banerji, Anil; Kotaiah, S.

    2005-01-01

    A third generation synchrotron radiation source of energy 2.5 GeV named INDUS-2 at Centre for Advanced Technology (C.A.T), Indore (M.P) is in the advanced stage of construction. Accurate determination and correction of beam closed orbit in INDUS-2 machine within 100 of microns is a very desirable goal. Bench based calibration of Beam Position Indicators (BPI) play a very important and useful role during initial commissioning of electron machines. To precisely measure transverse position of electron beam in the Indus-2 storage ring, 56 Beam Position Indicators (BPI) will be installed in INDUS-2 machine. Out of 56 Beam Position Indicators 40 are of individual type whereas 16 are integrated with dipole vacuum chamber. The Beam Position Indicators are required to be calibrated before they can be installed. The calibration is done to determine electrical offset with respect to defined mechanical centre, to determine displacement sensitivities as well as non linearity's of BPI. Ideally when beam passes through the geometrical center of BPI's, all electrodes should have same signal strength. However due to different capacitance of electrodes and offset and drift in electronics, the electrical centre (mechanical x, y where all electrodes shows same signal strength) differs from mechanical centre of BPI. A fully automatic calibration system has been developed to carry out the calibration of Beam Position Indicators. A calibration software has been developed which has necessary utilities to process and display calibration data and results. This paper describes the calibration results of Indus-2 BPM. (author)

  19. [Family physicians attitude towards quality indicator program].

    Science.gov (United States)

    Shani, Michal; Nakar, Sasson; Azuri, Yossi

    2012-10-01

    Quality indicator programs for primary care are implanted throughout the world improving quality in health care. In this study, we have assessed family physicians attitudes towards the quality indicators program in Israel. Questionnaires were distributed to family physicians in various continuing educational programs. The questionnaire addressed demographics, whether the physician dealt with quality indicators, time devoted by the physician to quality indicators, pressure placed on the physician related to quality indicators, and the working environment. A total of 140 questionnaires were distributed and 91 (65%) were completed. The average physician age was 49 years (range 33-65 years]; the average working experience as a family physician was 17.8 years (range 0.5-42); 58 physicians were family medicine specialist (65.9%). Quality indicators were part of the routine work of 94% of the physicians; 72% of the physicians noted the importance of quality indicators; 84% of the physicians noted that quality indicators demand better team work; 76% of the physicians noted that quality indicators have reduced their professional independence. Pressure to deal with quality indicators was noted by 72% of the family physicians. Pressure to deal with quality indicators was related to reduced loyalty to their employer (P = 0.001), reducing their interest to practice family medicine (p work (p = 0.001). It is important that policy makers find the way to leverage the advantages of quality indicator programs, without creating a heavy burden on the work of family physicians.

  20. Performance Indicators of Indoor Environmental Quality (IEQ ...

    African Journals Online (AJOL)

    Sultan

    buildings. Keywords: Building performance, hospital buildings, indicators, indoor environment quality. ATBU Journal of Environmental Technology 10, 1, June 2017. 139. Page 2. Performance Indicators of Indoor Environmental Quality (IEO) Assessment in Hospital Buildings: .... sustainability strategies into healthcare.

  1. Longitudinal Beam measurements at the LHC: The LHC Beam Quality Monitor

    CERN Document Server

    Papotti, G; Follin, F; Wehrle, U

    2011-01-01

    The LHC Beam Quality Monitor is a system that measures individual bunch lengths and positions, similarly to the twin system SPS Beam Quality Monitor, from which it was derived. The pattern verification that the system provides is vital during the injection process to verify the correctness of the injected pattern, while the bunch length measurement is fed back to control the longitudinal emittance blow up performed during the energy ramp and provides a general indication of the health of the RF system. The algorithms used, the hardware implementation and the system integration in the LHC control infrastructure are presented in this paper, along with possible improvements.

  2. Generalized beam quality factor of aberrated truncated Gaussian laser beams

    CSIR Research Space (South Africa)

    Mafusire, C

    2011-07-01

    Full Text Available very much like a normal lens (without the rotational symmetry associated with defocus) since the beam quality factor is calculated in the principal axes. With y-astigmatism, the lenslike behavior does not take place in the principal axes where...,13]. In this work we have adopted the sensible approach of choosing the principal axes Fig. 1. (Color online) Added far-field divergence due to the aperture size as a result of truncation. 1374 J. Opt. Soc. Am. A / Vol. 28, No. 7 / July 2011 C. Mafusire and A...

  3. Dimensionality reduction of quality of life indicators

    OpenAIRE

    Andrea Jindrová; Julie Poláčková

    2012-01-01

    Selecting indicators for assessing the quality of life at the regional level is not unambigous. Currently, there are no precisely defined indicators that would give comprehensive information about the quality of life on a local level. In this paper we focus on the determination (selection) of groups of indicators that can be interpreted, on the basis of studied literature, as factors characterizing the quality of life. Furthermore, on the application of methods to reduce the dimensionality of...

  4. High quality electron beams from a laser wakefield accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Wiggins, S M; Issac, R C; Welsh, G H; Brunetti, E; Shanks, R P; Anania, M P; Cipiccia, S; Manahan, G G; Aniculaesei, C; Ersfeld, B; Islam, M R; Burgess, R T L; Vieux, G; Jaroszynski, D A [SUPA, Department of Physics, University of Strathclyde, Glasgow (United Kingdom); Gillespie, W A [SUPA, Division of Electronic Engineering and Physics, University of Dundee, Dundee (United Kingdom); MacLeod, A M [School of Computing and Creative Technologies, University of Abertay Dundee, Dundee (United Kingdom); Van der Geer, S B; De Loos, M J, E-mail: m.wiggins@phys.strath.ac.u [Pulsar Physics, Burghstraat 47, 5614 BC Eindhoven (Netherlands)

    2010-12-15

    High quality electron beams have been produced in a laser-plasma accelerator driven by femtosecond laser pulses with a peak power of 26 TW. Electrons are produced with an energy up to 150 MeV from the 2 mm gas jet accelerator and the measured rms relative energy spread is less than 1%. Shot-to-shot stability in the central energy is 3%. Pepper-pot measurements have shown that the normalized transverse emittance is {approx}1{pi} mm mrad while the beam charge is in the range 2-10 pC. The generation of high quality electron beams is understood from simulations accounting for beam loading of the wakefield accelerating structure. Experiments and self-consistent simulations indicate that the beam peak current is several kiloamperes. Efficient transportation of the beam through an undulator is simulated and progress is being made towards the realization of a compact, high peak brilliance free-electron laser operating in the vacuum ultraviolet and soft x-ray wavelength ranges.

  5. Dimensionality reduction of quality of life indicators

    Directory of Open Access Journals (Sweden)

    Andrea Jindrová

    2012-01-01

    Full Text Available Selecting indicators for assessing the quality of life at the regional level is not unambigous. Currently, there are no precisely defined indicators that would give comprehensive information about the quality of life on a local level. In this paper we focus on the determination (selection of groups of indicators that can be interpreted, on the basis of studied literature, as factors characterizing the quality of life. Furthermore, on the application of methods to reduce the dimensionality of these indicators, from the source of the database CULS KROK, which provides statistics on the regional and districts level. To reduce the number of indicators and the subsequent creation of derived variables that capture the relationships between selected indicators multivariate statistical analysis methods, especially method of principal components and factor analysis were used. This paper also indicates the methodology grant project “Methodological Approaches to assess Subjective Aspects of the life quality in regions of the Czech Republic”.

  6. Average spreading and beam quality evolution of Gaussian array beams propagating through oceanic turbulence

    International Nuclear Information System (INIS)

    Zhi, Dong; Chen, Yizhu; Tao, Rumao; Ma, Yanxing; Zhou, Pu; Si, Lei

    2015-01-01

    The propagation properties of a radial Gaussian beam array through oceanic turbulence are studied analytically. The analytical expressions for the average intensity and the beam quality (power-in-the-bucket (PIB) and M 2 -factor) of a radial beam array in a turbulent ocean are derived based on an account of statistical optics methods, the extended Huygens-Fresnel principle, and the second order moments of the Wigner distribution function. The influences of w, ε, and χ T on the average intensity are investigated. The array divergence increases and the laser beam spreads as the salinity-induced dominant, ε decreased, and χ T increased. Further, the analytical expression of PIB and the M 2 -factor in the target plane is obtained. The changes of PIB and the M 2 -factor with three oceanic turbulence parameters indicate that the stronger turbulence with a larger w, smaller ε, and larger χ T results in the value of PIB decreasing, the value of the M 2 -factor increasing, and the beam quality degrading. (letter)

  7. Urbanization, housing and environmental quality indicators ...

    African Journals Online (AJOL)

    Urbanization, housing and environmental quality indicators. ... Journal of Agriculture, Forestry and the Social Sciences ... Urbanization ideally should also imply an enhancement of housing quality and other components of human settlements such as power supply, portable water, good roads, proper refuse and sewage ...

  8. A laser beam quality definition based on induced temperature rise.

    Science.gov (United States)

    Miller, Harold C

    2012-12-17

    Laser beam quality metrics like M(2) can be used to describe the spot sizes and propagation behavior of a wide variety of non-ideal laser beams. However, for beams that have been diffracted by limiting apertures in the near-field, or those with unusual near-field profiles, the conventional metrics can lead to an inconsistent or incomplete description of far-field performance. This paper motivates an alternative laser beam quality definition that can be used with any beam. The approach uses a consideration of the intrinsic ability of a laser beam profile to heat a material. Comparisons are made with conventional beam quality metrics. An analysis on an asymmetric Gaussian beam is used to establish a connection with the invariant beam propagation ratio.

  9. [Emergency departments: pediatric quality indicators as guide to quality assurance].

    Science.gov (United States)

    2004-06-01

    Measuring the quality of care in emergency departments requires tools to quantify the most important aspects in the care process. The quality indicator is the quantitative measure used in quality assurance. To review the document created by the Catalan Society of Emergency Medicine (SCME) and the Avedis Donabedian Foundation (FAD) in which the quality indicators for the emergency departments were established and to incorporate their methodology and select the indicators that could be adapted to pediatric emergencies. To add new indicators that, in the opinion of experts in pediatric emergencies, could be useful in daily pediatric care. To agree on the definitive list of indicators for use in pediatric emergencies and to define those that will be considered the main indicators. To develop a document on behalf of the Spanish Society of Pediatric Emergencies (SEUP), which will serve as a reference in quality of care. In the first stage, a Working Group of the SEUP was formed. The SCME/FAD paper was distributed after exclusion of the indicators that were not applicable to children. Each member adapted the indicators and proposed others. The Working Group then chose a set of indicators considered essential in any pediatric emergency department. The final document has 89 indicators, each with the following parameters: dimension, justification, ratio, explanation of terms, population, type, sources of information, standard and comments. Depending on the content, they are classified in one of the following sections: diseases, activities and work areas. Eighteen indicators were adapted to the pediatric age group. Twenty new indicators were added and 12 were proposed as basic or essential. The quality indicators are useful in measuring concrete and specific aspects of clinical care and in providing information on quality. The indicators provide valid, reliable and objective information. The indicator is an early warning sign to identify areas requiring improvement and allows

  10. Minimal requirements for quality controls in radiotherapy with external beams

    International Nuclear Information System (INIS)

    1999-01-01

    Physical dosimetric guidelines have been developed by the Italian National Institute of Health study group on quality assurance in radiotherapy to define protocols for quality controls in external beam radiotherapy. While the document does not determine strict rules or firm recommendations, it suggests minimal requirements for quality controls necessary to guarantee an adequate degree of accuracy in external beam radiotherapy [it

  11. Clinical quality indicators of venous leg ulcers

    DEFF Research Database (Denmark)

    Kjaer, Monica L; Mainz, Jan; Soernsen, Lars T

    2005-01-01

    and reliable evidence-based quality indicators of venous leg ulcer care. A Scandinavian multidisciplinary, cross-sectional panel of wound healing experts developed clinical quality indicators on the basis of scientific evidence from the literature and subsequent group nominal consensus of the panel......; an independent medical doctor tested the feasibility and reliability of these clinical indicators, assessing the quality of medical technical care on 100 consecutive venous leg ulcer patients. Main outcome measures were healing, recurrence, pain, venous disease diagnosis, differential diagnosis and treatment......%) were assessed for venous surgery. Distal arterial pressure was measured following initial examination in 33 of the patients (34%). All patients (100%) were prescribed compression therapy. Of the 98 patients, 11 (11%) had ulcers recur in 3 months and 72 (73%) healed in 12 months, which is in line...

  12. Evaluation of beam quality for high-power lasers

    Science.gov (United States)

    Yang, Hongru; Wu, Lei; Wang, Xuexin; Shi, Jifang; Li, Gaoping; Ji, Xiao

    2008-03-01

    High-power lasers are widely used in various scientific, industrial and military applications. There is currently a desire for precision measurement the beam quality of high-power lasers in order to evaluate the performance of the laser systems and the operational effectiveness of chemical and solid-state high-power laser weapons. There are many methods of beam quality determination, such as beam parameter product, encircled energy ratio BQ, Strehi ratio, diffraction limit factor β and beam propagation factor M2. In this paper, a beam quality measurement device is developed for high-power lasers. This device consists of a beam attenuator with large reflective ratio and minimal wavefront distortion, an off-axis parabolic mirror, an imaging lens and an infrared focal plane array detector. The laser beam intensity distribution, beam width, beam divergence and beam pointing stability can be obtained in real-time and the beam quality can be evaluated by the various determinations through imaging process. Advantages and disadvantages of these beam quality determination for evaluation the performance of the high-power lasers are analyzed and discussed. The measurement uncertainties of relative parameters are also analyzed and discussed.

  13. Soil Quality Indicator: a new concept

    Science.gov (United States)

    Barão, Lúcia; Basch, Gottlieb

    2017-04-01

    During the last century, cultivated soils have been intensively exploited for food and feed production. This exploitation has compromised the soils' natural functions and many of the soil-mediated ecosystems services, including its production potential for agriculture. Also, soils became increasingly vulnerable and less resilient to a wide range of threats. To overcome this situation, new and better management practices are needed to prevent soil from degradation. However, to adopt the best management practices in a specific location, it is necessary to evaluate the soil quality status first. Different soil quality indicators have been suggested over the last decades in order to evaluate the soil status, and those are often based on the performance of soil chemical, physical and biological properties. However, the direct link between these properties and the associated soil functions or soil vulnerability to threats appears more difficult to be established. This present work is part of the iSQAPER project- Interactive Soil Quality Assessment in Europe and China for Agricultural Productivity and Environmental Resilience, where new soil quality concepts are explored to provide better information regarding the effects of the most promising agricultural management practices on soil quality. We have developed a new conceptual soil quality indicator which determines the soil quality status, regarding its vulnerability towards different threats. First, different indicators were specifically developed for each of the eight threats considered - Erosion, SOM decline, Poor Structure, Poor water holding capacity, Compaction, N-Leaching, Soil-borne pests and diseases and Salinization. As an example for the case of Erosion, the RUSLE equation for the estimate of the soil annual loss was used. Secondly, a reference classification was established for each indicator to integrate all possible results into a Good, Intermediate or Bad classification. Finally, all indicators were

  14. Evaluation of headache service quality indicators

    DEFF Research Database (Denmark)

    Katsarava, Zaza; Gouveia, Raquel Gil; Jensen, Rigmor

    2015-01-01

    BACKGROUND: Evaluating quality of health care is increasingly recognized as an important contributor to the advancement of health-care delivery. We recently developed a set of quality indicators for headache care, intended to be applicable across countries, cultures and settings so that deficienc......BACKGROUND: Evaluating quality of health care is increasingly recognized as an important contributor to the advancement of health-care delivery. We recently developed a set of quality indicators for headache care, intended to be applicable across countries, cultures and settings so...... that deficiencies in headache care worldwide might be recognized and rectified. These indicators themselves require evaluation and proof of fitness for purpose. This pilot study begins this process. METHODS: We tested the quality indicators in the tertiary headache centres of the University of Duisburg......: The questionnaires were easily understood by both HCPs and patients and were not unduly time-consuming. The results from the two headache centres were comparable despite their differences in structure, staffing and language. These findings met the purpose of the study. Diagnoses were made according to ICHD criteria...

  15. Adjustment of nursing home quality indicators

    Directory of Open Access Journals (Sweden)

    Hirdes John P

    2010-04-01

    Full Text Available Abstract Background This manuscript describes a method for adjustment of nursing home quality indicators (QIs defined using the Center for Medicaid & Medicare Services (CMS nursing home resident assessment system, the Minimum Data Set (MDS. QIs are intended to characterize quality of care delivered in a facility. Threats to the validity of the measurement of presumed quality of care include baseline resident health and functional status, pattern of comorbidities, and facility case mix. The goal of obtaining a valid facility-level estimate of true quality of care should include adjustment for resident- and facility-level sources of variability. Methods We present a practical and efficient method to achieve risk adjustment using restriction and indirect and direct standardization. We present information on validity by comparing QIs estimated with the new algorithm to one currently used by CMS. Results More than half of the new QIs achieved a "Moderate" validation level. Conclusions Given the comprehensive approach and the positive findings to date, research using the new quality indicators is warranted to provide further evidence of their validity and utility and to encourage their use in quality improvement activities.

  16. Sidewall quality in proton beam writing

    International Nuclear Information System (INIS)

    Chiam, S.Y.; Kan, J.A. van; Osipowicz, T.; Udalagama, C.N.B.; Watt, F.

    2007-01-01

    Proton beam writing has been shown to allow the fabrication of high aspect ratio nanostructures at sub-100 nm dimension and with smooth and vertical sidewalls. For applications such as the fabrication of waveguides, sidewall smoothness is an important issue. We report results from investigations into side wall roughness measured directly with Atomic Force Microscopy. Structures were written in bulk poly(methylmethacrylate) (PMMA) with 2 MeV protons specifically to allow side access. We studied the effects of different scanning algorithms and also the variation of wall roughness with development time and ion penetration depth. Our results indicate that sidewall rms roughness of less than 7 nm is readily achievable. Multi-loop scanning and optimization of the scanning algorithm can lead to significant improvements in sidewall smoothness

  17. Summary Of Session 4: How Do We Monitor Beam Quality?

    International Nuclear Information System (INIS)

    Karantzoulis, E.

    2001-01-01

    Up to the end of the 80's beam quality was mainly believed to be connected only to the intensity i.e. beam quantity. However, with the new colliders already functioning or programmed, new and more (also in safety) demanding production machines (e.g. isotope) and the many new 3rd generation synchrotron radiation sources that accommodate many experimental lines, the beam quality (BQ) issue has to be re-examined, re-evaluated and re-defined. (author)

  18. Summary Of Session 4: How Do We Monitor Beam Quality?

    Energy Technology Data Exchange (ETDEWEB)

    Karantzoulis, E

    2001-07-01

    Up to the end of the 80's beam quality was mainly believed to be connected only to the intensity i.e. beam quantity. However, with the new colliders already functioning or programmed, new and more (also in safety) demanding production machines (e.g. isotope) and the many new 3rd generation synchrotron radiation sources that accommodate many experimental lines, the beam quality (BQ) issue has to be re-examined, re-evaluated and re-defined. (author)

  19. Saturne II: characteristics of the proton beam, field qualities and corrections, acceleration of the polarized protons

    International Nuclear Information System (INIS)

    Laclare, J.-L.

    1978-01-01

    Indicated specifications of Saturne II are summed up: performance of the injection system, quality of the guidance field (magnetic measurements and multipolar corrections), transverse and longitudinal instabilities, characteristics of the beam stored in the machine and of the extracted beam. The problem of depolarization along the acceleration cycle is briefly discussed (1 or 2% between injection and 3 GeV) [fr

  20. Numerical determination of injector design for high beam quality

    International Nuclear Information System (INIS)

    Boyd, J.K.

    1985-01-01

    The performance of a free electron laser strongly depends on the electron beam quality or brightness. The electron beam is transported into the free electron laser after it has been accelerated to the desired energy. Typically the maximum beam brightness produced by an accelerator is constrained by the beam brightness deliverd by the accelerator injector. Thus it is important to design the accelerator injector to yield the required electron beam brightness. The DPC (Darwin Particle Code) computer code has been written to numerically model accelerator injectors. DPC solves for the transport of a beam from emission through acceleration up to the full energy of the injector. The relativistic force equation is solved to determine particle orbits. Field equations are solved for self consistent electric and magnetic fields in the Darwin approximation. DPC has been used to investigate the beam quality consequences of A-K gap, accelerating stress, electrode configuration and axial magnetic field profile

  1. [Indication for mitral valve interventions: Development of a quality indicator for external hospital quality assurance].

    Science.gov (United States)

    Köster, Christina; Schorbach, Lena; Wrede, Stephanie; Meyer, Sven; Kazmaier, Tonia; Szecsenyi, Joachim

    2017-11-01

    The indication for a mitral valve intervention is an important patient-relevant parameter for the assessment of process quality and the comparison of healthcare providers. In this article, we describe the development of a corresponding quality indicator for an external hospital quality assurance (QA) procedure in Germany. An expert panel was set up by the aQua Institute to assist with the development of a QA procedure for mitral valve interventions and the associated quality indicators. In a comprehensive, systematic literature and evidence research, the American and European guidelines were identified as the best evidence available. Especially the more current American guideline formed the basis on which a quality indicator dealing with the correct indication for a mitral valve intervention was developed. The developed quality indicator assesses the proportion of patients for whom an indication for a mitral valve intervention was determined in compliance with guideline recommendations. The indicator differentiates between surgical and catheter-based procedures. To determine whether or not the indication was correct, different medical parameters are included, such as, for example, type of mitral valve defect, etiology of the disease, severity of symptoms, valve morphology (e. g., mitral valve area), valve hemodynamics and comorbidity, which healthcare providers have to document. The documentation for the developed quality indicator is considerable. Nonetheless, its relevance is undeniable because it allows the user to determine whether a surgical or catheter-based mitral valve intervention was necessary and performed according to guideline recommendations. In the first year of its implementation, this indicator should be evaluated for further improvement and simplification of assessment. Copyright © 2017. Published by Elsevier GmbH.

  2. Soil enzymes: health and quality indicators

    Directory of Open Access Journals (Sweden)

    Laura E. Cerón Rincón

    2005-01-01

    define sustainability, in other words, the maintenance of their functions inside the limits of an ecosystem. The health and quality indicators are a set of measurements (physical, chemical and biological properties that pretend to establish quality standards for this resource; the enzymatic activity is placed inside this set because of its close relationship with the other properties and because of its sensibleness to the changes due to handling and use. The present review pretends to illustrate how the tracking of the biological catalysis of the soil through uses and alterations that an ecosystem may suffer, may supply information for the understanding of how the processes responsible for the maintenance of functions such as biomass production, pollutant remediation and cycling of nutrients, suffer changes and if these are positive, negative or iterative.

  3. FIELD TEST OF THE FLAME QUALITY INDICATOR

    Energy Technology Data Exchange (ETDEWEB)

    Rudin, Andrew M; Butcher, Thomas; Troost, Henry

    2003-02-04

    The flame quality indicator concept was developed at BNL specifically to monitor the brightness of the flame in a small oil burner and to provide a ''call for service'' notification when the brightness has changed from its setpoint, either high or low. In prior development work BNL has explored the response of this system to operational upsets such as excess air changes, fouled atomizer nozzles, poor fuel quality, etc. Insight Technologies, Inc. and Honeywell, Inc. have licensed this technology from the U.S. Department of Energy and have been cooperating to develop product offerings which meet industry needs with an optimal combination of function and price. Honeywell has recently completed the development of the Flame Quality Monitor (FQM or Honeywell QS7100F). This is a small module which connects via a serial cable to the burners primary operating control. Primary advantages of this approach are simplicity, cost, and ease of installation. Call-for-service conditions are output in the form of front panel indicator lights and contact closure which can trigger a range of external communication options. Under this project a field test was conducted of the FQM in cooperation with service organizations in Virginia, Pennsylvania, New Jersey, New York, and Connecticut. At total of 83 field sites were included. At each site the FQM was installed in parallel with another embodiment of this concept--the Insight AFQI. The AFQI incorporates a modem and provides the ability to provide detailed information on the trends in the flame quality over the course of the two year test period. The test site population was comprised of 79.5% boilers, 13.7% warm air furnaces, and 6.8% water heaters. Nearly all were of residential size--with firing rates ranging from 0.6 gallons of oil per hour to 1.25. During the course of the test program the monitoring equipment successfully identified problems including: plugged fuel lines, fouled nozzles, collapsed combustion

  4. Quality indicators for woodwind reed material

    International Nuclear Information System (INIS)

    Glave, Stefan; Pallon, Jan; Bornman, Chris; Bjoern, Lars Olof; Wallen, Rita; Raastam, Jacob; Kristiansson, Per; Elfman, Mikael; Malmqvist, Klas

    1999-01-01

    For the generation of sound, some woodwind musical instruments, e.g. oboe, bassoon, clarinet and saxophone, are provided with mouthpieces made from reeds. These reeds are the culms of Arundo donax, a tall, cane-like perennial grass. A general problem is that the material is of varying quality, yet externally differences cannot be observed. Hence, large proportions of the prepared reeds are unusable. One hypothesis is that the changes in quality are correlated with differences in the chemical and anatomical structure of the tissue. Therefore, a comparison of superior and inferior mouthpieces, used by professional musicians, was undertaken to determinate potential indicators of quality. Nuclear microprobe analysis of reeds was carried out and complemented by scanning electron and light microscopy. The elemental levels of Si, P, S, Cl, K and Ca were compared between good and poor mouthpieces using appropriate statistical tests. No statistically significant differences could be identified. Microscopical observations showed that partial occlusion of vessels by tylose formation was associated with material deemed unusable

  5. Evaluation of diet quality indicators in adults

    Directory of Open Access Journals (Sweden)

    Katarína Fatrcová-Šramková

    2013-11-01

    Full Text Available 96 800x600 Normal 0 false false false CS JA X-NONE Several indices evaluate the quality of diet. The indices are based on nutrient requirements and dietary guidelines for the prevention of chronic diseases (to reduce the risk of chronic diseases. The Healthy Eating Index, Healthy Diet Indicator, and Diet Quality Index consist of components, which represent different aspects of a healthy diet. The indicators of diet quality are based on dietary intake data from 24-hour dietary recalls.  The aim of the research was to evaluate the nutrition of adults according to the selected criteria of three diet quality indicators: Healthy Eating Index, Healthy Diet Indicator, Diet Quality Index. 234 nutrition daily records were evaluated (from 78 probands per 3 days. Nutritional intake and blood biochemical parameters were defined in 56 females and 22 men (72% and 28% respectively aged from 24 to 62 years. The nutritional software Alimenta 4.3e (Food Research Institute, Bratislava, Slovakia, 2004 was used to calculate the nutrient intake. The evaluation of nutrition intake was focused on four parameters/recommendations of the Healthy Eating Index (to reduce total fat intake to 30% or less of energy, to reduce saturated fatty acid intake to less than 10% of energy, to reduce cholesterol intake to less than 300 mg daily, to limit total daily intake of sodium to 2400 mg or less, on five parameters/recommendations of the Healthy Diet Indicator (saturated fatty acids 0-10% of energy intake, polyunsaturated fatty acids 3-7% of energy intake, protein 10-15% of energy intake, dietary fiber 27-40 g, cholesterol 0-300 mg, on five parameters/recommendations of the Diet Quality Index (to reduce total fat intake to 30% or less of energy, to reduce saturated fatty acid intake to less than 10% of energy, to reduce cholesterol intake to less than 300 mg daily, to limit total daily intake of sodium to 2400 mg or less, to maintain adequate calcium intake – approximately

  6. Quality Indicators for the Total Testing Process.

    Science.gov (United States)

    Plebani, Mario; Sciacovelli, Laura; Aita, Ada

    2017-03-01

    ISO 15189:2012 requires the use of quality indicators (QIs) to monitor and evaluate all steps of the total testing process, but several difficulties dissuade laboratories from effective and continuous use of QIs in routine practice. An International Federation of Clinical Chemistry and Laboratory Medicine working group addressed this problem and implemented a project to develop a model of QIs to be used in clinical laboratories worldwide to monitor and evaluate all steps of the total testing process, and decrease error rates and improve patient services in laboratory testing. All laboratories are invited, at no cost, to enroll in the project and contribute to harmonized management at the international level. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Generation of High Quality Laser Accelerated Ion Beams

    OpenAIRE

    Esirkepov, T. Zh.; Bulanov, S. V.; Nishihara, K.; Tajima, T.; Pegoraro, F.; Khoroshkov, V. S.; Mima, K.; Daido, H.; Kato, Y.; Kitagawa, Y.; Nagai, K.; Sakabe, S.

    2002-01-01

    In order to achieve a high quality, i. e. monoergetic, intense ion beam, we propose the use of a double layer target. The first layer, at the target front, consists of high-Z atoms, while the second (rear) layer is a thin coating of low-Z atoms. The high quality proton beams from the double layer target, irradiated by an ultra-intense laser pulse, are demonstrated with three dimensional Particle-in-Cell simulations.

  8. Cone Beam CT vs. Fan Beam CT: A Comparison of Image Quality and Dose Delivered Between Two Differing CT Imaging Modalities.

    Science.gov (United States)

    Lechuga, Lawrence; Weidlich, Georg A

    2016-09-12

    A comparison of image quality and dose delivered between two differing computed tomography (CT) imaging modalities-fan beam and cone beam-was performed. A literature review of quantitative analyses for various image quality aspects such as uniformity, signal-to-noise ratio, artifact presence, spatial resolution, modulation transfer function (MTF), and low contrast resolution was generated. With these aspects quantified, cone beam computed tomography (CBCT) shows a superior spatial resolution to that of fan beam, while fan beam shows a greater ability to produce clear and anatomically correct images with better soft tissue differentiation. The results indicate that fan beam CT produces superior images to that of on-board imaging (OBI) cone beam CT systems, while providing a considerably less dose to the patient.

  9. Efficient generation of high beam-quality attosecond pulse with polarization-gating Bessel-Gauss beam from highly-ionized media.

    Science.gov (United States)

    Li, Yang; Zhang, Qingbin; Hong, Weiyi; Wang, Shaoyi; Wang, Zhe; Lu, Peixiang

    2012-07-02

    Single attosecond pulse generation with polarization gating Bessel-Gauss beam in relatively strongly-ionized media is investigated. The results show that Bessel-Gauss beam has the ability to suppress the spatial plasma dispersion effects caused by high density of free electrons, thus the laser field can maintain its spatial profile through highly-ionized medium. This indicates the use of Bessel-Gauss beam has advantages over Gaussian beam in high harmonic generation under high ionization conditions. In our scheme, significant improvement of spatiotemporal properties of harmonics is achieved and an isolated attosecond pulse with high beam quality is filtered out using polarization gating.

  10. Image Quality Indicator for Infrared Inspections

    Science.gov (United States)

    Burke, Eric

    2011-01-01

    The quality of images generated during an infrared thermal inspection depends on many system variables, settings, and parameters to include the focal length setting of the IR camera lens. If any relevant parameter is incorrect or sub-optimal, the resulting IR images will usually exhibit inherent unsharpness and lack of resolution. Traditional reference standards and image quality indicators (IQIs) are made of representative hardware samples and contain representative flaws of concern. These standards are used to verify that representative flaws can be detected with the current IR system settings. However, these traditional standards do not enable the operator to quantify the quality limitations of the resulting images, i.e. determine the inherent maximum image sensitivity and image resolution. As a result, the operator does not have the ability to optimize the IR inspection system prior to data acquisition. The innovative IQI described here eliminates this limitation and enables the operator to objectively quantify and optimize the relevant variables of the IR inspection system, resulting in enhanced image quality with consistency and repeatability in the inspection application. The IR IQI consists of various copper foil features of known sizes that are printed on a dielectric non-conductive board. The significant difference in thermal conductivity between the two materials ensures that each appears with a distinct grayscale or brightness in the resulting IR image. Therefore, the IR image of the IQI exhibits high contrast between the copper features and the underlying dielectric board, which is required to detect the edges of the various copper features. The copper features consist of individual elements of various shapes and sizes, or of element-pairs of known shapes and sizes and with known spacing between the elements creating the pair. For example, filled copper circles with various diameters can be used as individual elements to quantify the image sensitivity

  11. Measuring Beam Quality of Hollow Core Photonic Crystal Fibers

    DEFF Research Database (Denmark)

    Shephard, J.D.; Roberts, John; Jones, J.D.C.

    2006-01-01

    In this paper, the authors measure the quality of the delivered beam from hollow core photonic crystal fibers (HC-PCFs). The$M^2$parameter is determined, and the near- to far-field transition is examined. The influence on these properties due to the presence of a core surround mode is evaluated....... The applicability of the International Standards Organization 11146 : 1999 standard for$M^2$measurement of the beam quality of HC-PCFs is discussed. Because they are dependent on the measurement parameters, such as choice of aperturing scheme and the axis of measurement,$M^2$values could vary from 1.32 to 3.......17 for the same output beam. This highlights the need for careful consideration when measuring and describing the beam quality delivered by these novel photonic fibers....

  12. Analytical quality, performance indices and laboratory service

    DEFF Research Database (Denmark)

    Hilden, Jørgen; Magid, Erik

    1999-01-01

    analytical error, bias, cost effectiveness, decision-making, laboratory techniques and procedures, mass screening, models, statistical, quality control......analytical error, bias, cost effectiveness, decision-making, laboratory techniques and procedures, mass screening, models, statistical, quality control...

  13. Indications for quality assurance in conformal radiotherapy in Italy

    International Nuclear Information System (INIS)

    Banci Buonamici, F.; DE Angelis, C.; Rosi, A.; Tabocchini, M.A.; Iotti, C.; Olmi, P.

    2008-01-01

    Intensity-Modulated Radiation Therapy (IMRT) is an advanced and promising technique of external beam irradiation. IMRT is able to conform the dose distribution to the 3D tumour shape also for complex geometries, preserving surrounding normal tissues and reducing the probability of side effects. IMRT is a time consuming and complex technique and its use demands high level quality assurance. It is, therefore, very important to define conditions for its utilization. Professionals of Radiotherapy Centres, with experience in the IMRT use, have constituted a multidisciplinary working group with the aim of developing indications in this field. Purpose of the present document is to highlight relevant aspects of the technique, but also to underline the high complexity of the technique, whose implementation requires extreme attention of the staff of Radiotherapy Centres involved [it

  14. Adaptive slab laser beam quality improvement using a weighted least-squares reconstruction algorithm.

    Science.gov (United States)

    Chen, Shanqiu; Dong, LiZhi; Chen, XiaoJun; Tan, Yi; Liu, Wenjin; Wang, Shuai; Yang, Ping; Xu, Bing; Ye, YuTang

    2016-04-10

    Adaptive optics is an important technology for improving beam quality in solid-state slab lasers. However, there are uncorrectable aberrations in partial areas of the beam. In the criterion of the conventional least-squares reconstruction method, it makes the zones with small aberrations nonsensitive and hinders this zone from being further corrected. In this paper, a weighted least-squares reconstruction method is proposed to improve the relative sensitivity of zones with small aberrations and to further improve beam quality. Relatively small weights are applied to the zones with large residual aberrations. Comparisons of results show that peak intensity in the far field improved from 1242 analog digital units (ADU) to 2248 ADU, and beam quality β improved from 2.5 to 2.0. This indicates the weighted least-squares method has better performance than the least-squares reconstruction method when there are large zonal uncorrectable aberrations in the slab laser system.

  15. Quality correction factors of composite IMRT beam deliveries: Theoretical considerations

    International Nuclear Information System (INIS)

    Bouchard, Hugo

    2012-01-01

    Purpose: In the scope of intensity modulated radiation therapy (IMRT) dosimetry using ionization chambers, quality correction factors of plan-class-specific reference (PCSR) fields are theoretically investigated. The symmetry of the problem is studied to provide recommendable criteria for composite beam deliveries where correction factors are minimal and also to establish a theoretical limit for PCSR delivery k Q factors. Methods: The concept of virtual symmetric collapsed (VSC) beam, being associated to a given modulated composite delivery, is defined in the scope of this investigation. Under symmetrical measurement conditions, any composite delivery has the property of having a k Q factor identical to its associated VSC beam. Using this concept of VSC, a fundamental property of IMRT k Q factors is demonstrated in the form of a theorem. The sensitivity to the conditions required by the theorem is thoroughly examined. Results: The theorem states that if a composite modulated beam delivery produces a uniform dose distribution in a volume V cyl which is symmetric with the cylindrical delivery and all beams fulfills two conditions in V cyl : (1) the dose modulation function is unchanged along the beam axis, and (2) the dose gradient in the beam direction is constant for a given lateral position; then its associated VSC beam produces no lateral dose gradient in V cyl , no matter what beam modulation or gantry angles are being used. The examination of the conditions required by the theorem lead to the following results. The effect of the depth-dose gradient not being perfectly constant with depth on the VSC beam lateral dose gradient is found negligible. The effect of the dose modulation function being degraded with depth on the VSC beam lateral dose gradient is found to be only related to scatter and beam hardening, as the theorem holds also for diverging beams. Conclusions: The use of the symmetry of the problem in the present paper leads to a valuable theorem showing

  16. Clinical indications and perspectives for intraoperative cone-beam computed tomography in oral and maxillofacial surgery.

    Science.gov (United States)

    Pohlenz, Philipp; Blessmann, Marco; Blake, Felix; Heinrich, Sven; Schmelzle, Rainer; Heiland, Max

    2007-03-01

    Intraoperative cone-beam computerized tomography (CBCT) imaging has been introduced in oral and maxillofacial surgery. Using midfacial fractures as the pioneer model, this study describes the spectrum of further promising clinical indications for intraoperative CBCT and a clinical combination with intraoperative navigation. One hundred seventy-nine patients admitted for surgical treatment of the facial skeleton were included in the study. Intraoperatively, 3-dimensional images were generated with the mobile CBCT scanner Arcadis Orbic 3D, obtained from Siemens Medical Solutions, in a variety of indications. The acquisition of the data sets was uncomplicated, and image quality was sufficient to assess the postoperative result in all cases. In the example of a facial gunshot injury, a navigation system for intraoperative localization of the metal foreign bodies was used.

  17. Quality Indicators and Outcomes of Emergency Caesarean ...

    African Journals Online (AJOL)

    Uterine rupture and cesarean hysterectomy were associated with an outcome of neonatal death (p<0.001). Infrastructure and personnel limitations are major barriers to the improvement of quality of cesarean deliveries. Future endeavors towards quality improvement must address these deficiencies. (Afr J Reprod Health ...

  18. The SPS Beam quality monitor, from design to operation

    CERN Document Server

    Papotti, G; Follin, F; Shaposhnikova, E

    2011-01-01

    The SPS Beam Quality Monitor is a system that monitors longitudinal beam parameters on a cycle-by-cycle basis and prevents extraction to the LHC in case the specifications are not met. This avoids losses, unnecessary stress of machine protection components and luminosity degradation, additionally helping efficiency during the filling process. The system has been operational since the 2009 LHC run, checking the beam pattern, its correct position with respect to the LHC references, individual bunch lengths and stability. In this paper the algorithms used, the hardware implementation and the operational aspects are presented.

  19. Measurement system with high accuracy for laser beam quality.

    Science.gov (United States)

    Ke, Yi; Zeng, Ciling; Xie, Peiyuan; Jiang, Qingshan; Liang, Ke; Yang, Zhenyu; Zhao, Ming

    2015-05-20

    Presently, most of the laser beam quality measurement system collimates the optical path manually with low efficiency and low repeatability. To solve these problems, this paper proposed a new collimated method to improve the reliability and accuracy of the measurement results. The system accuracy controlled the position of the mirror to change laser beam propagation direction, which can realize the beam perpendicularly incident to the photosurface of camera. The experiment results show that the proposed system has good repeatability and the measuring deviation of M2 factor is less than 0.6%.

  20. Cherenkov detector for beam quality measurement

    Science.gov (United States)

    Orfanelli, S.; CMS Collaboration

    2016-07-01

    A new detector to measure the machine induced background at larger radii has been developed and installed in the CMS experiment at the LHC. It consists of forty modules, each comprising a quartz bar read out by a photomultiplier tube. Since Cherenkov radiation is emitted in a forward cone around the charged particle trajectory, these detectors can distinguish between the arrival directions of the machine induced background and the collision products. The back-end electronics consists of a uTCA readout with excellent time resolution. The installation in the CMS is described and first commissioning measurements with the LHC beams in Run II are presented.

  1. LHC Injection Beam Quality During LHC Run I

    CERN Document Server

    AUTHOR|(CDS)2079186; Kain, Verena; Stapnes, Steinar

    The LHC at CERN was designed to accelerate proton beams from 450 GeV to 7 TeV and collide them in four large experiments. The 450 GeV beam is extracted from the last pre-accelerator, the SPS, and injected into the LHC via two 3 km long transfer lines, TI 2 and TI 8. The injection process is critical in terms of preservation of beam quality and machine protection. During LHC Run I (2009-2013) the LHC was filled with twelve high intensity injections per ring, in batches of up to 144 bunches of 1.7*10^11 protons per bunch. The stored beam energy of such a batch is already an order of magnitude above the damage level of accelerator equipment. Strict quality and machine protection requirements at injection have a significant impact on operational efficiency. During the first years of LHC operation, the injection phase was identified as one of the limiting factors for fast LHC turnaround time. The LHC Injection Quality Check (IQC) software framework was developed as a part of this thesis to monitor the beam quality...

  2. The generation of high-quality, intense ion beams by ultra-intense lasers

    CERN Document Server

    Roth, M; Audebert, Patrick; Blazevic, A; Brambrink, E; Cowan, T E; Fuchs, J; Gauthier, J C; Geissel, M; Hegelich, M; Karsch, S; Meyer-Ter-Vehn, J; Ruhl, H; Schlegel, T; Stephens, R B

    2002-01-01

    Intense beams of protons and heavy ions have been observed in ultra-intense laser-solid interaction experiments. Thereby, a considerable fraction of the laser energy is transferred to collimated beams of energetic ions (e.g. up to 50 MeV protons; 100 MeV fluorine), which makes these beams highly interesting for various applications. Experimental results indicate a very short-pulse duration and an excellent beam quality, leading to beam intensities in the TW range. To characterize the beam quality and its dependence on laser parameters and target conditions we performed experiments using the 100 TW laser system at Laboratoire pour l'Utilisation des Lasers Intenses at the Ecole Polytechnique, France, with focused intensities exceeding 10 sup 1 sup 9 W cm sup - sup 2. We found a strong dependence on the target rear surface conditions allowing to tailor the ion beam by an appropriate target design. We also succeeded in the generation of heavy ion beams by suppressing the proton amount at the target surface. We wi...

  3. Indicators of quality in primary healthcare.

    NARCIS (Netherlands)

    Berg, M.J. van den; Bakker, D.H. de

    2004-01-01

    Background: GPs play a pivotal role in the Dutch healthcare system. Since GPs have a so-called gatekeeper-function, the overwhelming majority of medical problems is served by GPs. The Inspectorate of Health Care (IHC) is charged with the supervision of public health, including the quality of care

  4. Technical Note: Evaluation of the latency and the beam characteristics of a respiratory gating system using an Elekta linear accelerator and a respiratory indicator device, Abches.

    Science.gov (United States)

    Saito, Masahide; Sano, Naoki; Ueda, Koji; Shibata, Yuki; Kuriyama, Kengo; Komiyama, Takafumi; Marino, Kan; Aoki, Shinichi; Onishi, Hiroshi

    2018-01-01

    To evaluate the basic performance of a respiratory gating system using an Elekta linac and an Abches respiratory-monitoring device. The gating system was comprised of an Elekta Synergy linac equipped with a Response TM gating interface module and an Abches respiratory-monitoring device. The latencies from a reference respiratory signal to the resulting Abches gating output signal and the resulting monitor-ion-chamber output signal were measured. Then, the flatness and symmetry of the gated beams were measured using a two-dimensional ionization chamber array for fixed and arc beams, respectively. Furthermore, the beam quality, TPR 20,10 , and the output of the fixed gated beams were also measured using a Farmer chamber. Each of the beam characteristics was compared with each of those for nongated irradiation. The full latencies at beam-on and beam-off for 6-MV gated beams were 336.4 ± 23.4 ms and 87.6 ± 7.1 ms, respectively. The differences in flatness between the gated and nongated beams were within 0.91% and 0.87% for the gun-target and left-right directions, respectively. In the same manner, the beam symmetries were within 0.68% and 0.82%, respectively. The percentage differences in beam quality and beam output were below 1% for a beam-on time range of 1.1-7 s. The latency of the Elekta gating system combined with Abches was found to be acceptable using our measurement method. Furthermore, we demonstrated that the beam characteristics of the gating system using our respiratory indicator were comparable with the nongated beams for a single-arc gated beam delivery. © 2017 American Association of Physicists in Medicine.

  5. Citations: Indicators of Quality? The Impact Fallacy

    NARCIS (Netherlands)

    Leydesdorff, L.; Bornmann, L.; Comins, J.A.; Milojević, S.

    2016-01-01

    We argue that citation is a composed indicator: short-term citations can be considered as currency at the research front, whereas long-term citations can contribute to the codification of knowledge claims into concept symbols. Knowledge claims at the research front are more likely to be transitory

  6. Development of indicators of the quality of radiotherapy for localized prostate cancer.

    Science.gov (United States)

    Danielson, Brita; Brundage, Michael; Pearcey, Robert; Bass, Brenda; Pickles, Tom; Bahary, Jean-Paul; Foley, Kimberley; Mackillop, William

    2011-04-01

    To develop a set of indicators of the quality of radiotherapy (RT) for localized prostate cancer. Following a comprehensive review of the literature to identify candidate quality indicators, we utilized a modified Delphi technique to develop a set of indicators of the quality of RT for localized prostate cancer. The first Delphi round consisted of an online survey in which radiation oncologists were asked to rate the importance of the candidate quality indicators. The second round was a face-to-face meeting of a smaller group of radiation oncologists to discuss, rate, and rank a final set of quality indicators. The literature review identified 57 candidate quality indicators. After the two rounds of the Delphi process, a final set of 25 indicators was agreed upon. The set includes quality indicators covering all aspects of prostate cancer radical RT management: pre-treatment assessment, external beam RT, brachytherapy, androgen deprivation therapy, and follow-up. This new set of quality indicators is more comprehensive than others described in the literature, and can be applied to patterns of care studies that assess the quality of RT for prostate cancer. The process used to develop this set of indicators can be readily adapted for use in other contexts. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  7. Evaluation of Soil Quality: Application of Fuzzy Indicators

    Science.gov (United States)

    The problem of assessing soil quality is considered as the fuzzy modeling task. Fuzzy indicator concept (FIC) is used as a general platform for the assessment of soil quality as a "degree or grade of perfection”. The FIC can be realized through the utilization of fuzzy soil quality indicators (FSQI)...

  8. Quality indicators for the adult epilepsy monitoring unit.

    Science.gov (United States)

    Sauro, Khara M; Wiebe, Samuel; Macrodimitris, Sophie; Jetté, Nathalie

    2016-11-01

    Quality and safety in epilepsy monitoring units (EMUs) are of great importance because patients' seizures are induced rather than prevented in this hospital setting. However, the measurement and evaluation of quality and safety in EMUs are heterogeneous, as are practices and processes of care. To improve the measurement of quality and safety in EMUs, we sought to develop evidence-based and consensus-driven quality indicators, adhering to previously described methodologic standards. Candidate quality indicators were identified using a recent systematic review on quality and safety indicators in EMUs. These were supplemented by expert opinion to identify other indicators that had not been reported previously. The candidate quality indicators were then evaluated using a modified Delphi technique among a multidisciplinary EMU quality improvement team. Candidate indicators identified as important and feasible through the Delphi technique were then developed into quality metrics. Thirty-four candidate indicators were abstracted from 135 studies included in the earlier systematic review, and two additional candidate indicators were suggested through consensus from experts. Consensus was reached after two modified Delphi rounds for 25 quality indicators identified as important. These 25 indicators were then developed into quality metrics using a standardized data collection form and were deployed in an online database for systematic data capture and further analyses. These quality indicators have the potential to improve the reporting of quality and safety in EMUs through standardized measurement and evaluation of the quality and safety of care. The ultimate goal is improved patient care and clinical outcomes through safer and better care for people with epilepsy in the EMU. Wiley Periodicals, Inc. © 2016 International League Against Epilepsy.

  9. Fitting relationship between the beam quality β factor of high-energy laser and the wavefront aberration of laser beam

    Science.gov (United States)

    Ji, Zhong-Ye; Zhang, Xiao-Fang

    2018-01-01

    The mathematical relation between the beam quality β factor of high-energy laser and the wavefront aberration of laser beam is important in beam quality control theory of the high-energy laser weapon system. In order to obtain this mathematical relation, numerical simulation is used in the research. Firstly, the Zernike representations of typically distorted atmospheric wavefront aberrations caused by the Kolmogoroff turbulence are generated. And then, the corresponding beam quality β factors of the different distorted wavefronts are calculated numerically through fast Fourier transform. Thus, the statistical distribution rule between the beam quality β factors of high-energy laser and the wavefront aberrations of the beam can be established by the calculated results. Finally, curve fitting method is chosen to establish the mathematical fitting relationship of these two parameters. And the result of the curve fitting shows that there is a quadratic curve relation between the beam quality β factor of high-energy laser and the wavefront aberration of laser beam. And in this paper, 3 fitting curves, in which the wavefront aberrations are consisted of Zernike Polynomials of 20, 36, 60 orders individually, are established to express the relationship between the beam quality β factor and atmospheric wavefront aberrations with different spatial frequency.

  10. Comparison of photon beam qualities for treatment of deep seated tumours

    International Nuclear Information System (INIS)

    Ssengabi, J.

    1977-06-01

    Physical parameters that influence the quality of photon beams have been examined. The interaction of photon beams of different qualities from cobolt-60 gamma rays to 42 MV X-rays, with a patient-target region system has been investigated with a view to compare the photon beam qualities under specified irradiation conditions. The concept of integral dose and its use in photon beam intercomparison has been investigated. The results of the study have shown the inadequacy of a single beam parameter, such as the central axis depth dose data, in the intercomparison of photon beam qualities for the treatment of deep seated tumours. (author)

  11. METHOD FOR DETERMINING QUALITY INDICATORS OF ELECTRICAL POWER

    Directory of Open Access Journals (Sweden)

    Ion S. ANTONIU

    2009-05-01

    Full Text Available This paper proposes to introduce a small number of quality indicators for electrical power in systems with three-phased consumers which are disbalanced, asymmetrical and distorting. These indicators are required for measuring and predetermining the effects of such consumers on the supply network in order to establish measures for improving the quality of power supply in the electrical networks.

  12. Postharvest quality of cut roses following electron-beam irradiation

    International Nuclear Information System (INIS)

    Chang, A.Y.; Gladon, R.J.; Gleason, M.L.; Parker, S.K.; Agnew, N.H.; Olson, D.G.

    1997-01-01

    Cut Rosa x hybrida L. 'Royalty' flowers were used to determine the efficacy of electron-beam irradiation for increasing postharvest quality and decreasing petal infection by Botrytis cinerea Pers. In an experiment for determining the injury threshold, roses received electron-beam irradiation of 0, 0.5, 1, 2, and 4 kGy. Irradiation dosages greater than or equal to 4 kGy caused necrosis on petal tissue and decreased postharvest life at 20 degrees C. In a second experiment to evaluate postharvest quality, roses were irradiated at 0, 0.25, 0.5, 0.75, and 1 kGy. Dosages of 0.25 and 0.5 kGy slowed the rate of flower bud opening for 2 days but did not decrease postharvest quality when compared with nonirradiated roses. Roses that received irradiation dosages of 0.75 and 1 kGy showed unacceptable quality. In a third experiment, roses that had or had not been inoculated with B. cinerea were irradiated at 0, 0.25, 0.5, and 0.75 kGy. Irradiation did not control B. cinerea populations, and rose quality decreased as dosage increased. In a fourth experiment to determine the effect of irradiation on B. cinerea, conidia on water-agar plates exposed to dosages less than or equal to 1, 2, and 4 kGy germinated at rates of approximately 90%, 33%, and 2%, respectively, within 24 h

  13. A set of care quality indicators for stroke management.

    Science.gov (United States)

    Navarro Soler, I M; Ignacio García, E; Masjuan Vallejo, J; Gállego Culleré, J; Mira Solves, J J

    2017-06-22

    This study proposes a set of quality indicators for care outcomes in patients with acute cerebral infarction. These indicators are understandable and relevant from a clinical viewpoint, as well as being acceptable and feasible in terms of time required, ease of data capture, and interpretability. The method consisted of reaching consensus among doctors after having reviewed the literature on quality indicators in stroke. We then designed and conducted a field study to assess the understandability and feasibility of the set of indicators. Consensus yielded 8 structural indicators, 5 process indicators, and 12 result indicators. Additionally, standards of reference were established for each indicator. This set of indicators can be used to monitor the quality care for stroke patients, identify strengths, and potentially to identify areas needing improvement. Copyright © 2017 Sociedad Española de Neurología. Publicado por Elsevier España, S.L.U. All rights reserved.

  14. [PRESSURE ULCER – HEALTHCARE QUALITY AND PATIENT SAFETY INDICATOR].

    Science.gov (United States)

    Mesarić, J

    2016-01-01

    Pressure ulcer is an undesired event for patient, frequently used in quality monitoring as an indicator of healthcare quality and patient safety. According to legal regulations in the Republic of Croatia, pressure ulcer is included in the group of indicators of other undesired events (patient safety) and healthcare institutions are obliged to monitor the applicable indicator and submit report to the Agency every six months. Annual reports on the patient safety indicators are available on the Agency website. The article presents the descriptive list of indicators and descriptive list for the Pressure Ulcer indicator.

  15. Improvement of the beam quality of a diode laser with two active broad-area segments

    DEFF Research Database (Denmark)

    Chi, Mingjun; Thestrup, B.; Mortensen, J.L.

    2003-01-01

    half of the freely running power of the laser was coupled out from the external cavity. The output power can be enhanced further by the feedback from the zeroth-order beam. The possibility of improving the beam quality further is discussed and a new double-external-cavity configuration is suggested.......The beam quality of a diode laser with two active segments was improved using an external cavity with collimating optics, a grating, and an output coupler. The beam quality of the output beam, which is the first-order diffractive beam from the grating, was improved by a factor of 2, and at least...

  16. National quality measurement using clinical indicators: the Danish National Indicator Project

    DEFF Research Database (Denmark)

    Mainz, Jan; Hansen, Anne-Marie; Palshof, Torben

    2009-01-01

    This article describes the Danish National Indicator Project that aims to document and improve the quality of care at national level. Specific clinical indicators, standards, and prognostic factors have been developed for eight diseases (e.g. lung cancer). It has been implemented in all clinical...... departments in Denmark. Participation is mandatory. Results related to lung cancer are presented and discussed. The experiences from 2000 to 2008 indicate that the quality of care related to the eight diseases improve over time and that that performance and outcome measurement will get paid in terms...... of quality improvement....

  17. Quality Management and Key Performance Indicators in Oncologic Esophageal Surgery.

    Science.gov (United States)

    Gockel, Ines; Ahlbrand, Constantin Johannes; Arras, Michael; Schreiber, Elke Maria; Lang, Hauke

    2015-12-01

    Ranking systems and comparisons of quality and performance indicators will be of increasing relevance for complex "high-risk" procedures such as esophageal cancer surgery. The identification of evidence-based standards relevant for key performance indicators in esophageal surgery is essential for establishing monitoring systems and furthermore a requirement to enhance treatment quality. In the course of this review, we analyze the key performance indicators case volume, radicality of resection, and postoperative morbidity and mortality, leading to continuous quality improvement. Ranking systems established on this basis will gain increased relevance in highly complex procedures within the national and international comparison and furthermore improve the treatment of patients with esophageal carcinoma.

  18. Electron beam water calorimetry measurements to obtain beam quality conversion factors.

    Science.gov (United States)

    Muir, Bryan R; Cojocaru, Claudiu D; McEwen, Malcolm R; Ross, Carl K

    2017-10-01

    To provide results of water calorimetry and ion chamber measurements in high-energy electron beams carried out at the National Research Council Canada (NRC). There are three main aspects to this work: (a) investigation of the behavior of ionization chambers in electron beams of different energies with focus on long-term stability, (b) water calorimetry measurements to determine absorbed dose to water in high-energy beams for direct calibration of ion chambers, and (c) using measurements of chamber response relative to reference ion chambers, determination of beam quality conversion factors, k Q , for several ion chamber types. Measurements are made in electron beams with energies between 8 MeV and 22 MeV from the NRC Elekta Precise clinical linear accelerator. Ion chamber measurements are made as a function of depth for cylindrical and plane-parallel ion chambers over a period of five years to investigate the stability of ion chamber response and for indirect calibration. Water calorimetry measurements are made in 18 MeV and 22 MeV beams. An insulated enclosure with fine temperature control is used to maintain a constant temperature (drifts less than 0.1 mK/min) of the calorimeter phantom at 4°C to minimize effects from convection. Two vessels of different designs are used with calibrated thermistor probes to measure radiation induced temperature rise. The vessels are filled with high-purity water and saturated with H 2 or N 2 gas to minimize the effect of radiochemical reactions on the measured temperature rise. A set of secondary standard ion chambers are calibrated directly against the calorimeter. Finally, several other ion chambers are calibrated in the NRC 60 Co reference field and then cross-calibrated against the secondary standard chambers in electron beams to realize k Q factors. The long-term stability of the cylindrical ion chambers in electron beams is better (always <0.15%) than plane-parallel chambers (0.2% to 0.4%). Calorimetry measurements

  19. Analysis of Quality Indicators in ADS-B Messages

    Directory of Open Access Journals (Sweden)

    Simon Tesi

    2017-07-01

    Full Text Available There is lack of available statistical data in the field of quality indicators in ADS-B messages, particularly in Czech airspace. Quality indicators in the ADS-B message define if this message can be used by ATM applications. This article is devoted to the analysis of quality indicators in the ADS-B messages. The data collected in the Czech airspace during six months were analysed. These data were statistically evaluated. The main objective is the statistical evaluation of the data and comparing them with quality requirements in Europe. The article deals with results of the statistics and assessment of the level of quality. Results are satisfactory and similar to the results published by EUROCONTROL and FAA. According to the examined data, 86.42% of them meets the EASA requirements in RAD environment. As ADS-B is not mandatory yet, it is possible to state that these results are satisfying.

  20. The quality of high-energy X-ray beams

    International Nuclear Information System (INIS)

    LaRiviere, P.D.

    1989-01-01

    Supplement 17 of the British Journal of Radiology is a survey of central-axis depth doses for radiotherapy machines, patterned largely on BJR Supplement 11 (1972). Inspection of high-energy X-ray depth doses for a 10 x 10 cm field at an SSD of 100 cm disclosed large differences between the two sets of data, especially for qualities above 8 MV, e.g. a depth dose of 80% at 10 cm is rated at about 19 MV according to BJR Supplement 11, and 23 MV according to BJR Supplement 17. It was found that Supplement 17 depth-dose data above 8 MV were erratic, but Supplement 11 data could be represented by an analytical expression, providing a unique means of assigning MV quality. It was also found that dose-weighted average energy of the filtered beam plotted smoothly against depth dose. For dosimetric purposes, it is suggested that this parameter be used as a true measure of beam quality, removing discrepancies introduced by the use of nominal MV for this purpose. (author)

  1. X-ray Computed Tomography Image Quality Indicator (IQI) Development

    Data.gov (United States)

    National Aeronautics and Space Administration — Phase one of the program is to identify suitable x-ray Computed Tomography (CT) Image Quality Indicator (IQI) design(s) that can be used to adequately capture CT...

  2. A quality audit program for external beam radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Hanson, W.F.; Stovall, M. [Univ. of Texas, Houston, TX (United States)

    1993-12-31

    For more than 25 years, the University of Texas M. D. Anderson Cancer Center has had a quality audit program using mailed dosimeters to verify radiation therapy machine output. Two programs, one compulsory and one voluntary, presently monitor therapy beams at more than 1000 megavoltage-therapy facilities. A successful program requires two major components: a high-precision thermoluminescent dosimeter (TLD) system and dedicated staff that interact closely with the users to resolve discrepancies. The TLD system, the logistics used, and the human interaction of these programs are described. Examples show that the programs can identify major discrepancies, exceeding 5 %, as well as discrepancies as small as 3%.

  3. A new method for improving beam quality of LINAC

    International Nuclear Information System (INIS)

    Xie Jialin; Li Fengtian; Wang Yanshan; Wang Bosi

    1999-01-01

    The principle of the self-adaptive feed-forward (SAFF) control to improve the beam quality of linac is introduced. the analytical procedure for calculating the control signals, the structure of a practical control system, and applications of SAFF in klystron, RF gun, and linac are presented, especially the application in the thermionic gun whose response is non-linear, time-variant and of large time-delay. The described control system is operational and some primary experimental results have been obtained, including the control of amplitude and phase fluctuations of the klystron output, the microwave field in the gun cavity and linac

  4. A quality audit program for external beam radiotherapy

    International Nuclear Information System (INIS)

    Hanson, W.F.; Stovall, M.

    1993-01-01

    For more than 25 years, the University of Texas M. D. Anderson Cancer Center has had a quality audit program using mailed dosimeters to verify radiation therapy machine output. Two programs, one compulsory and one voluntary, presently monitor therapy beams at more than 1000 megavoltage-therapy facilities. A successful program requires two major components: a high-precision thermoluminescent dosimeter (TLD) system and dedicated staff that interact closely with the users to resolve discrepancies. The TLD system, the logistics used, and the human interaction of these programs are described. Examples show that the programs can identify major discrepancies, exceeding 5 %, as well as discrepancies as small as 3%

  5. Preliminary investigation into some quality control indices for ...

    African Journals Online (AJOL)

    An investigation of some quality control indices of selected grains stored in various locations in Makurdi farming environment was carried out. Grain quality factors are classified into those measurable defects as broken grains, insect damage, mould infestation, presence of foreign materials, and moisture content which ...

  6. Quality indicators for integrated care of dysphagia in hospital settings.

    Science.gov (United States)

    Moraes, Danielle Pedroni; Andrade, Claudia Regina Furquim de

    2011-03-01

    This article proposes a panel of quality indicators for the management of swallowing rehabilitation (SR) therapy in a hospital setting. There were four stages in developing these indicators: identifying procedures to be managed; generating indicators and standardizing data collection; identifying the correlation among indicators; and formulating the panel of indicators. The following 12 quality indicators were developed: swallowing evaluation index; individual care index; speech-language pathologist (SLP) care index; number of assisted patients index; severity rate; swallowing diagnosis rate per hospital unit; swallowing rehabilitation demand index; time until first swallowing evaluation; SLP index per hospital bed; time until removal of feeding tube; time until reintroduction of oral feeding; and time until decannulation. The proposed indicators were designed to improve the management of dysphagia in a hospital setting. Measuring these indicators is essential to understanding the patient's needs and providing quality care. Managing care using these indicators will make it easier to track the patient's rehabilitation process, measure the effectiveness of new therapeutic processes and technologies, and evaluate the performance of hospital units relative to other providers in the area. The management of SR using quality indicators allows the effectiveness and efficiency of rehabilitation programs to be clearly evaluated.

  7. Absorbed-dose beam quality conversion factors for cylindrical chambers in high energy photon beams.

    Science.gov (United States)

    Seuntjens, J P; Ross, C K; Shortt, K R; Rogers, D W

    2000-12-01

    Recent working groups of the AAPM [Almond et al., Med. Phys. 26, 1847 (1999)] and the IAEA (Andreo et al., Draft V.7 of "An International Code of Practice for Dosimetry based on Standards of Absorbed Dose to Water," IAEA, 2000) have described guidelines to base reference dosimetry of high energy photon beams on absorbed dose to water standards. In these protocols use is made of the absorbed-dose beam quality conversion factor, kQ which scales an absorbed-dose calibration factor at the reference quality 60Co to a quality Q, and which is calculated based on state-of-the-art ion chamber theory and data. In this paper we present the measurement and analysis of beam quality conversion factors kQ for cylindrical chambers in high-energy photon beams. At least three chambers of six different types were calibrated against the Canadian primary standard for absorbed dose based on a sealed water calorimeter at 60Co [TPR10(20)=0.572, %dd(10)x=58.4], 10 MV [TPR10(20)=0.682, %dd(10)x=69.6), 20 MV (TPR10(20)=0.758, %dd(10)x= 80.5] and 30 MV [TPR10(20) = 0.794, %dd(10)x= 88.4]. The uncertainty on the calorimetric determination of kQ for a single chamber is typically 0.36% and the overall 1sigma uncertainty on a set of chambers of the same type is typically 0.45%. The maximum deviation between a measured kQ and the TG-51 protocol value is 0.8%. The overall rms deviation between measurement and the TG-51 values, based on 20 chambers at the three energies, is 0.41%. When the effect of a 1 mm PMMA waterproofing sleeve is taken into account in the calculations, the maximum deviation is 1.1% and the overall rms deviation between measurement and calculation 0.48%. When the beam is specified using TPR10(20), and measurements are compared with kQ values calculated using the version of TG-21 with corrected formalism and data, differences are up to 1.6% when no sleeve corrections are taken into account. For the NE2571 and the NE2611A chamber types, for which the most literature data are

  8. Elements and indicators for identification of quality of primary education

    Directory of Open Access Journals (Sweden)

    Sučević Vlasta M.

    2015-01-01

    Full Text Available Education is one of the main pillars of the quality of knowledge, and, in turn, social progress in general. There are numerous positions concerning quality of education, some more, and some less detailed. In order to determine the quality of a primary school, for example as 'poor', 'mediocre' or 'excellent', we use, more or less precisely, a certain idea about the value, and thus identify, again with a certain extent of accuracy, the position of the school in question in relation to other schools. In terms of the quality of education, it is necessary to analyze all segments of educational process. This includes the analysis of objectives of educational process, products of quality education as well as adequate and accessible technical-instrumental, that is, operational-procedural level of quality of educational process. Most authors connect the quality of primary education to results, that is, outcomes of education. In order to achieve quality of education, we need to achieve quality of particular components or elements of the whole of education. This paper deals with theoretical review of elements and indicators of quality of basic education, and provides a review of pedagogical strategies and their effect on certain components of quality with the aim to improve the effects on pedagogical and didactical resources of the quality of education.

  9. An electron beam imaging system for quality assurance in IORT

    Science.gov (United States)

    Casali, F.; Rossi, M.; Morigi, M. P.; Brancaccio, R.; Paltrinieri, E.; Bettuzzi, M.; Romani, D.; Ciocca, M.; Tosi, G.; Ronsivalle, C.; Vignati, M.

    2004-01-01

    Intraoperative radiation therapy is a special radiotherapy technique, which enables a high dose of radiation to be given in a single fraction during oncological surgery. The major stumbling block to the large-scale application of the technique is the transfer of the patient, with an open wound, from the operating room to the radiation therapy bunker, with the consequent organisational problems and the increased risk of infection. To overcome these limitations, in the last few years a new kind of linear accelerator, the Novac 7, conceived for direct use in the surgical room, has become available. Novac 7 can deliver electron beams of different energies (3, 5, 7 and 9 MeV), with a high dose rate (up to 20 Gy/min). The aim of this work, funded by ENEA in the framework of a research contract, is the development of an innovative system for on-line measurements of 2D dose distributions and electron beam characterisation, before radiotherapy treatment with Novac 7. The system is made up of the following components: (a) an electron-light converter; (b) a 14 bit cooled CCD camera; (c) a personal computer with an ad hoc written software for image acquisition and processing. The performances of the prototype have been characterised experimentally with different electron-light converters. Several tests have concerned the assessment of the detector response as a function of impulse number and electron beam energy. Finally, the experimental results concerning beam profiles have been compared with data acquired with other dosimetric techniques. The achieved results make it possible to say that the developed system is suitable for fast quality assurance measurements and verification of 2D dose distributions.

  10. Air Quality Monitoring with Routine Utilization of Ion Beam Analysis

    International Nuclear Information System (INIS)

    Wegrzynek, D.

    2013-01-01

    Full text: Information on source contributions to ambient air particulate concentrations is a vital tool for air quality management. Traditional gravimetric analysis of airborne particulate matter is unable to provide information on the sources contributing to air particulate concentrations. Ion beam analysis is used to identify the elemental composition of air particulates for source apportionment and determining the relative contribution of biogenic and anthropogenic sources to air particulate pollution. The elemental composition is obtained by proton induced X-ray emission technique (PIXE), which is an ion beam analysis (IBA) technique. The element concentrations are deduced from the X ray spectra produced when the particulate collected on a filter is bombarded with a high-energy proton beam. As part of the UNDP/IAEA/RCA Project RAS/8/082 ‘Better Management of the Environment, Natural Resources and Industrial Growth through Isotope and Radiation Technology,’ a collaborative alliance was formed between the Institute of Geological and Nuclear Sciences Limited and the Wellington Regional Council, New Zeland [1]. The purpose of the project was to examine the elemental composition of air particulate matter and determine the origins through source apportionment techniques. In New Zealand PM 10 and PM 2.5 fractions have been collected at the industrial area of Seaview, Wellington over two years using a GENT stacked filter unit sampler. Concentrations of elements with atomic mass above neon were determined using ion beam analysis and elemental carbon concentrations were determined using a reflectometer. Specific ambient source elemental 'fingerprints' were then determined by factor analysis and the relative contributions of various local and regional sources were assessed. The significant factors (sources) were determined to be sea salt, soil, industry, and combustion sources. Local industry was found to contribute to ambient lead concentrations. (author)

  11. Identifying quality indicators of surgical training: A national survey.

    Science.gov (United States)

    Bhatti, Nasir I; Ahmed, Aadil; Choi, Sukgi S

    2015-12-01

    Evidence shows a positive association between quality of surgical training received and patient outcomes. Traditionally, improved patient outcomes are linked with increased operative volume. However, generalizing this finding to surgeons in training is unclear. In addition, reduced exposure due to work-hour restrictions calls for alternative methods to determine the quality of training. The purpose of this study was to identify the indicators of high-quality training by surveying the trainees and trainers. A questionnaire was developed based on input from faculty and previous studies. The survey was divided into three sections asking about the indicators of quality training, methods to measure them, and interventions for improvement. The questionnaire was administered to program directors (PDs) and senior residents of otolaryngology training programs nationwide. The strongest indicators of quality training that were agreed upon by both residents and PDs were having faculty development as an ideal trainer while having a balanced level of supervision and independence, logbooks for exposure to volume and variety of pathology, continuous evaluation and provision of feedback. However, structured teaching, simulation-based training, and trainee exam scores failed to reach an agreement as a metric of high-quality surgical training. Measuring quality of a residency training program is imperative to produce competent surgeons and ensuring patient safety. The results of this study will help the residency programs to better train their residents and improve the quality of their teaching. N/A. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.

  12. A primer on quality indicators of distance education.

    Science.gov (United States)

    Chaney, Beth H; Eddy, James M; Dorman, Steve M; Glessner, Linda L; Green, B Lee; Lara-Alecio, Rafael

    2009-04-01

    In the past decade, there has been an enormous growth of distance education courses and programs in higher education. The growth of distance education is particularly evident in the field of health education. However, the enormous potential of distance education is tempered by one overriding question: How does one ensure that distance education coursework and degrees are of high quality? To this end, the purpose of this study is twofold: to identify quality indicators of distance education and to provide implications of the identified quality indicators for health education researchers and practitioners. The results of the study reveal common benchmarks and quality indicators that all parties deem important in designing, implementing, and evaluating distance education courses and programs.

  13. Assessing Water Quality: Staphylococci as Microbial Indicators in Swimming Pools.

    Science.gov (United States)

    Rivera, Jo. Bechaida T.; Adera, Tilahun

    1991-01-01

    This study suggests that staphylococci may be the preferred microbial indicators of swimming pool water quality because these organisms met all criteria for best microbial indicators in terms of amount of recovery, resistance to disinfectants, and risk to bathers using water samples from nine swimming pools in Linn and Benton Counties, Oregon. (30…

  14. Utility of pollution indices in assessment of soil quality around ...

    African Journals Online (AJOL)

    The quality of soil in the vicinity of Madaka mining sites were investigated in this study using Environmental Pollution Indices. Geological mapping of the study area indicated that the area was dominated by schist and granite. The static water level measurement revealed a westward groundwater flow direction which also ...

  15. Indicators of quality of work as predictors of quality of life

    OpenAIRE

    Alina Mariuca Ionescu

    2013-01-01

    The paper aims to analyze the extent to which the indicators of the quality of work can be seen as good predictors of the quality of life. To describe the various aspects of the quality of work and employment, data on answers to 12 questions covering 7 dimensions of quality of work were extracted from the European Working Conditions Survey (EWCS) database available on Eurofound website. Four wellknown composite indicators were considered for the assessment of the quality of life: Economist In...

  16. Improving the beam quality of the neutron radiography facility using the SLOWPOKE-2 at the Royal Military College of Canada

    International Nuclear Information System (INIS)

    Lewis, W.J.; Bennett, L.G.I.; Teshima, P.

    1996-01-01

    At the SLOWPOKE-2 Facility at the Royal Military College of Canada, a neutron radiography facility has been designed and installed, and the beam quality has been improved by performing a series of radiographs using American standard for testing and materials (ASTM) E 545 indicators. Other means of determining the progress such as bubble detectors and activation foils were used. Modifications to the nosepiece of the beam tube including shielding and linings for fast neutron and gamma radiation were made. (orig.)

  17. Quality indicators for technologies applied to the hospital pharmacy

    Directory of Open Access Journals (Sweden)

    Amelia de la Rubia Nieto

    2017-07-01

    Full Text Available The TECNO group of the Sociedad Española de Farmacia Hospitalaria (Spanish Society of Hospital Pharmacy has addressed the definition of a catalogue of indicators for performance, quality and safety in the use of technologies applied to the logistic activity of Hospital Pharmacy Units.The project was developed with a methodology of qualitative techniques by consensus, with the members of the TECNO Group participating as experts. Once indicators had been defined, a validation phase was conducted, and standards were established based on the result of the sampling carried out in the hospitals of the group members.A total of 28 indicators were obtained, with their corresponding quality standards applied to the use of technologies in the processed for medication storage, dispensing and preparation.The definition of quality indicators and their standards for measuring technologies in the use of medication represents a step forward in the improvement of their safety

  18. Quality indicators in digestive endoscopy: introduction to structure, process, and outcome common indicators.

    Science.gov (United States)

    López-Picazo, Julio; Alberca de Las Parras, Fernando; Sánchez Del Río, Antonio; Pérez Romero, Shirley; León Molina, Joaquín; Júdez, Francisco Javier

    2017-06-01

    The general goal of the project wherein this paper is framed is the proposal of useful quality and safety procedures and indicators to facilitate quality improvement in digestive endoscopy units. This initial offspring sets forth procedures and indicators common to all digestive endoscopy procedures. First, a diagram of pre- and post-digestive endoscopy steps was developed. A group of health care quality and/or endoscopy experts under the auspices of the Sociedad Española de Patología Digestiva (Spanish Society of Digestive Diseases) carried out a qualitative review of the literature regarding the search for quality indicators in endoscopic procedures. Then, a paired analysis was used for the selection of literature references and their subsequent review. Twenty indicators were identified, including seven for structure, eleven for process (five pre-procedure, three intra-procedure, three post-procedure), and two for outcome. Quality of evidence was analyzed for each indicator using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) classification.

  19. Ambulatory Quality Indicators to Prevent Infection in Sickle Cell Disease

    OpenAIRE

    Beverung, Lauren M.; Brousseau, David; Hoffmann, Raymond G.; Yan, Ke; Panepinto, Julie A.

    2014-01-01

    The purpose of the present study was to identify rates of adherence for three outpatient quality indicators noted by Wang and colleagues (2011): (1) influenza vaccine, (2) pneumococcal immunizations, and (3) penicillin prophylaxis in patients with sickle cell disease (SCD) in a Medicaid sample. These variables were chosen based on Wang and colleagues’ suggestion that these variables are important for the assessment of the quality of care of children with SCD. We hypothesized that the overall ...

  20. Valuation of Biochemical and Microbiological Indicators in Soil Quality Assessment

    OpenAIRE

    Peruzzi, Elisabetta

    2017-01-01

    This thesis research aimed at valuating the suitability of biochemical and microbiological indicators in soil quality and soil health assessment, applying an interdisciplinary approach by means of different methodologies. As the concept of soil quality encompasses both functionality and biological diversity, two cases of study are proposed and each of them aimed at the description of this two aspects. The first case study examined the degree of interference of high soil copper contamination w...

  1. Quality indicators for global benchmarking of localised prostate cancer management.

    Science.gov (United States)

    Sampurno, Fanny; Zheng, Jia; Di Stefano, Lydia; Millar, Jeremy L; Foster, Claire; Fuedea, Ferran; Higano, Celestia; Hulan, Hartwig; Mark, Stephen; Moore, Caroline; Richardson, Alison; Sullivan, Frank; Wenger, Neil S; Wittmann, Daniela; Evans, Sue

    2018-02-22

    To develop a core set of clinical indicators that enables international benchmarking of localised prostate cancer management using data available in the TrueNTH Global Registry. An international expert panel completed an online survey and participated in a face-to-face meeting. Participants included urologists (n=3), radiation oncologists (n=3), psychologists (n=2), medical oncologist (n=1), nurse (n=1) and an epidemiologist (n=1) with prostate cancer expertise from seven countries. Current guidelines on prostate cancer treatment and potential quality indicators were identified from a literature review. These potential indicators were refined and developed through a modified Delphi process, during which each panellist independently and repeatedly rated each indicator based on its importance (satisfying the indicator demonstrates a provision of high-quality care) and feasibility (likelihood that data being used to construct the indicator could be collected at a population level). The main outcome measure was items with panel agreement (disagreement indexquality indicators assess care relating to diagnosis (n=7), primary treatment (n=7), salvage treatment (n=1) and health outcomes (n=18). In summary, we have developed a set of quality indicators for measuring prostate cancer care from numerous international evidence-based clinical guidelines. These indicators will be pilot tested in the TrueNTH Global Registry. Reports comparing indicator performance will subsequently be distributed to participating sites, with the purpose of improving the consistency and quality of prostate cancer management on a global basis. Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  2. SU-F-BRD-15: Quality Correction Factors in Scanned Or Broad Proton Therapy Beams Are Indistinguishable

    Energy Technology Data Exchange (ETDEWEB)

    Sorriaux, J; Lee, J [Molecular Imaging Radiotherapy & Oncology, Universite Catholique de Louvain, Brussels (Belgium); ICTEAM Institute, Universite catholique de Louvain, Louvain-la-Neuve (Belgium); Testa, M; Paganetti, H [Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, MA 02114, Massachusetts (United States); Bertrand, D; Orban de Xivry, J [Ion Beam Applications, Louvain-la-neuve, Brabant Wallon (Belgium); Palmans, H [EBG MedAustron GmbH, Wiener Neustadt (Austria); National Physical Laboratory, Teddington (United Kingdom); Vynckier, S [Cliniques Universitaires Saint-Luc, Brussels (Belgium); Sterpin, E [Molecular Imaging Radiotherapy & Oncology, Universite Catholique de Louvain, Brussels (Belgium)

    2015-06-15

    Purpose: The IAEA TRS-398 code of practice details the reference conditions for reference dosimetry of proton beams using ionization chambers and the required beam quality correction factors (kQ). Pencil beam scanning (PBS) requires multiple spots to reproduce the reference conditions. The objective is to demonstrate, using Monte Carlo (MC) calculations, that kQ factors for broad beams can be used for scanned beams under the same reference conditions with no significant additional uncertainty. We consider hereafter the general Alfonso formalism (Alfonso et al, 2008) for non-standard beam. Methods: To approach the reference conditions and the associated dose distributions, PBS must combine many pencil beams with range modulation and shaping techniques different than those used in passive systems (broad beams). This might lead to a different energy spectrum at the measurement point. In order to evaluate the impact of these differences on kQ factors, ion chamber responses are computed with MC (Geant4 9.6) in a dedicated scanned pencil beam (Q-pcsr) producing a 10×10cm2 composite field with a flat dose distribution from 10 to 16 cm depth. Ion chamber responses are also computed by MC in a broad beam with quality Q-ds (double scattering). The dose distribution of Q -pcsr matches the dose distribution of Q-ds. k-(Q-pcsr,Q-ds) is computed for a 2×2×0.2cm{sup 3} idealized air cavity and a realistic plane-parallel ion chamber (IC). Results: Under reference conditions, quality correction factors for a scanned composite field versus a broad beam are the same for air cavity dose response, k-(Q-pcsr,Q-ds) =1.001±0.001 and for a Roos IC, k-(Q-pcsr,Q-ds) =0.999±0.005. Conclusion: Quality correction factors for ion chamber response in scanned and broad proton therapy beams are identical under reference conditions within the calculation uncertainties. The results indicate that quality correction factors published in IAEA TRS-398 can be used for scanned beams in the SOBP of a

  3. SU-F-BRD-15: Quality Correction Factors in Scanned Or Broad Proton Therapy Beams Are Indistinguishable

    International Nuclear Information System (INIS)

    Sorriaux, J; Lee, J; Testa, M; Paganetti, H; Bertrand, D; Orban de Xivry, J; Palmans, H; Vynckier, S; Sterpin, E

    2015-01-01

    Purpose: The IAEA TRS-398 code of practice details the reference conditions for reference dosimetry of proton beams using ionization chambers and the required beam quality correction factors (kQ). Pencil beam scanning (PBS) requires multiple spots to reproduce the reference conditions. The objective is to demonstrate, using Monte Carlo (MC) calculations, that kQ factors for broad beams can be used for scanned beams under the same reference conditions with no significant additional uncertainty. We consider hereafter the general Alfonso formalism (Alfonso et al, 2008) for non-standard beam. Methods: To approach the reference conditions and the associated dose distributions, PBS must combine many pencil beams with range modulation and shaping techniques different than those used in passive systems (broad beams). This might lead to a different energy spectrum at the measurement point. In order to evaluate the impact of these differences on kQ factors, ion chamber responses are computed with MC (Geant4 9.6) in a dedicated scanned pencil beam (Q-pcsr) producing a 10×10cm2 composite field with a flat dose distribution from 10 to 16 cm depth. Ion chamber responses are also computed by MC in a broad beam with quality Q-ds (double scattering). The dose distribution of Q -pcsr matches the dose distribution of Q-ds. k-(Q-pcsr,Q-ds) is computed for a 2×2×0.2cm 3 idealized air cavity and a realistic plane-parallel ion chamber (IC). Results: Under reference conditions, quality correction factors for a scanned composite field versus a broad beam are the same for air cavity dose response, k-(Q-pcsr,Q-ds) =1.001±0.001 and for a Roos IC, k-(Q-pcsr,Q-ds) =0.999±0.005. Conclusion: Quality correction factors for ion chamber response in scanned and broad proton therapy beams are identical under reference conditions within the calculation uncertainties. The results indicate that quality correction factors published in IAEA TRS-398 can be used for scanned beams in the SOBP of a high

  4. Water quality index and eutrophication indices of Caiabi River, MT

    Directory of Open Access Journals (Sweden)

    Grasiane Andrietti

    2016-03-01

    Full Text Available The objective of this study was to evaluate the water quality of the Caiabi River based upon the water quality index (WQI and the trophic state index (TSI, considering seasonal and spatial variations, with the aim of determining the most appropriate monitoring design for this study site. Sampling for water quality monitoring was conducted at five points on the Caiabi River from July 2012 to June 2013. Quality parameters quantified were as follows: pH, temperature, conductivity, dissolved oxygen, total and thermotolerant coliforms, turbidity, Kjeldahl nitrogen, nitrite, nitrate, total phosphorus, biochemical oxygen demand, series of solids, and chlorophyll a. Sampling procedures and analysis followed the methods recommended by the Standard Methods for the Examination of Water and Wastewater. The WQI results showed that the quality of the Caiabi River water is good. TSI results demonstrated the low risk of eutrophication in the Caiabi River, indicating an ultra-oligotrophic lotic environment. Analysis of variance showed that 10 of the 16 monitored quality parameters presented differences of means between the dry and rainy seasons or among the monitored points or in the interaction between seasons and points. These results indicate that two annual sampling collections at two points may be sufficient to describe the water quality behavior in the basin, as long as the conditions of land use are stable.

  5. Tracking of Power Quality Indicators during Wind Farm Islanding Experiment

    DEFF Research Database (Denmark)

    Terzija, V.; Crossley, P.A.; Stanojevic, V.

    2007-01-01

    The application of the two-stage Newton Type Algorithm for the tracking of the power quality indicators (in accordance with IEEE Standard 1459-2000) is presented in the paper. To estimate their spectra and fundamental frequency, the current and voltage signals are first processed and then the power...... quality indicators calculated. The algorithm considers frequency as an unknown parameter and estimates it whilst determining the input signal spectrum; this ensures the algorithm is insensitive to frequency changes. The proposed algorithm was evaluated using signals acquired during a wind farm islanding...

  6. Key interventions and quality indicators for quality improvement of STEMI care: a RAND Delphi survey.

    Science.gov (United States)

    Aeyels, Daan; Sinnaeve, Peter R; Claeys, Marc J; Gevaert, Sofie; Schoors, Danny; Sermeus, Walter; Panella, Massimiliano; Coeckelberghs, Ellen; Bruyneel, Luk; Vanhaecht, Kris

    2017-12-13

    Identification, selection and validation of key interventions and quality indicators for improvement of in hospital quality of care for ST-elevated myocardial infarction (STEMI) patients. A structured literature review was followed by a RAND Delphi Survey. A purposively selected multidisciplinary expert panel of cardiologists, nurse managers and quality managers selected and validated key interventions and quality indicators prior for quality improvement for STEMI. First, 34 experts (76% response rate) individually assessed the appropriateness of items to quality improvement on a nine point Likert scale. Twenty-seven key interventions, 16 quality indicators at patient level and 27 quality indicators at STEMI care programme level were selected. Eighteen additional items were suggested. Experts received personal feedback, benchmarking their score with group results (response rate, mean, median and content validity index). Consequently, 32 experts (71% response rate) openly discussed items with an item-content validity index above 75%. By consensus, the expert panel validated a final set of 25 key interventions, 13 quality indicators at patient level and 20 quality indicators at care programme level prior for improvement of in hospital care for STEMI. A structured literature review and multidisciplinary expertise was combined to validate a set of key interventions and quality indicators prior for improvement of care for STEMI. The results allow researchers and hospital staff to evaluate and support quality improvement interventions in a large cohort within the context of a health care system.

  7. Flattening filter free beams from TrueBeam and Versa HD units: Evaluation of the parameters for quality assurance

    Energy Technology Data Exchange (ETDEWEB)

    Fogliata, Antonella, E-mail: antonella.fogliata@humanitas.it; Reggiori, Giacomo; Stravato, Antonella; Scorsetti, Marta; Cozzi, Luca [Radiotherapy and Radiosurgery Department, Humanitas Research Hospital, Milan-Rozzano I-20098 (Italy); Fleckenstein, Jens; Schneider, Frank; Lohr, Frank [Department of Radiation Oncology, University Medical Center Mannheim, University of Heidelberg, Mannheim D-68167 (Germany); Pachoud, Marc; Ghandour, Sarah [Radiation Oncology Department, Hôpital Riviera Chablais, Vevey CH-1800 (Switzerland); Krauss, Harald [Radio-Oncology Department, Kaiser Franz Josef Spital, Vienna A-1100 (Austria)

    2016-01-15

    Purpose: Flattening filter free (FFF) beams generated by medical linear accelerators are today clinically used for stereotactical and non-stereotactical radiotherapy treatments. Such beams differ from the standard flattened beams (FF) in the high dose rate and the profile shape peaked on the beam central axis. Definition of new parameters as unflatness and slope for FFF beams has been proposed based on a renormalization factor for FFF profiles. The present study aims to assess the dosimetric differences between FFF beams generated by linear accelerators from different vendors, and to provide renormalization and parameter data of the two kinds of units. Methods: Dosimetric data from two Varian TrueBeam and two Elekta Versa HD linear accelerators, all with 6 and 10 MV nominal accelerating potentials, FF and FFF modes have been collected. Renormalization factors and related fit parameters according to Fogliata et al. [“Definition of parameters for quality assurance of flattening filter free (FFF) photon beams in radiation therapy,” Med. Phys. 39, 6455–6464 (2012)] have been evaluated for FFF beams of both units and energies. Unflatness and slope parameters from profile curves were evaluated. Dosimetric differences in terms of beam penetration and near-the-surface dose were also assessed. Results: FFF profile parameters have been updated; renormalization factors and unflatness from the Varian units are consistent with the published data. Elekta FFF beam qualities, different from the Varian generated beams, tend to express similar behaviour as the FF beam of the corresponding nominal energy. TPR{sub 20,10} for 6 and 10 MV FF and FFF TrueBeam beams are 0.665, 0.629 (6 MV) and 0.738, 0.703 (10 MV). The same figures for Versa HD units are 0.684, 0.678 (6 MV) and 0.734, 0.721 (10 MV). Conclusions: Renormalization factor and unflatness parameters evaluated from Varian and Elekta FFF beams are provided, in particular renormalization factors table and fit parameters.

  8. Quality indicators of laryngeal cancer care in the elderly.

    Science.gov (United States)

    Gourin, Christine G; Frick, Kevin D; Blackford, Amanda L; Herbert, Robert J; Quon, Harry; Forastiere, Arlene A; Eisele, David W; Dy, Sydney M

    2014-09-01

    To examine associations between quality of care, survival, and costs in elderly patients treated for laryngeal squamous cell cancer (SCCA). Retrospective analysis of Surveillance, Epidemiology, and End Results Medicare data. We evaluated 2,370 patients diagnosed with laryngeal SCCA from 2004 to 2007 using multivariate regression and survival analysis. Using quality indicators derived from guidelines for recommended care, summary measures of quality were calculated for diagnosis, initial treatment, surveillance, treatment of recurrence, end-of-life care, performance, and an overall summary measure of quality. High-quality care was associated with significant differences in survival for diagnosis [HR = 0.80, 95% CI (0.66-0.97)], initial treatment [HR = 0.75 (0.63-0.88)], surveillance [HR = 0.54 (0.44-0.66)], treatment of recurrence [HR = 1.54 (1.26-1.89)], end-of-life care [HR = 0.69 (0.52-0.92)], performance [HR = 0.41 (0.33-0.52)], and an overall summary measure of quality [HR = 0.66 (0.54-0.80)], which was significantly associated with lower mean incremental costs [-$24,958 (-$35,873 - -$14,042)]. There was a significant survival advantage for initial treatment with surgery and postoperative radiation [HR = 0.66 (0.53-0.82)] and high-volume surgical care [HR = 0.64 (0.43-0.96)] after controlling for all other variables, including quality of care. High-quality larynx cancer care in elderly patients was associated with improved survival and reduced costs; however, high-quality care for treatment of recurrence was associated with poorer survival. These data suggest that survival outcomes in elderly patients with laryngeal cancer are not entirely explained by differences in the receipt of quality care using existing treatment and performance quality indicators and also suggest a need to develop sensitive and valid quality indicators of larynx cancer care in this population. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  9. HEALTH AS THE QUALITY OF LIFE KEY INDICATOR

    Directory of Open Access Journals (Sweden)

    Z.Z. Biktimirova

    2006-09-01

    Full Text Available In this review health is regarded in the Quality of Life (QOL concept context. Definitions of health that go beyond other components of national well-being and allow to use it as the QOL indicator are distinguished. Systemic approaches to health estimation, their benefits and shortcomings are analyzed. We propose to use birth rate, newborn, infant and maternal mortality as the most important indicators.

  10. Indications for cone beam computed tomography in children and young patients in a Turkish subpopulation.

    Science.gov (United States)

    İşman, Özlem; Yılmaz, Hasan Hüseyin; Aktan, Ali Murat; Yilmaz, Büşra

    2017-05-01

    Cone beam computed tomography (CBCT) imaging is widely used in children; however, it remains controversial because of the health effects of radiation. This retrospective study investigated the indications for CBCT and dentomaxillofacial pathologies in paediatric patients. CBCT images of 329 paediatric patients (i.e., aged anomalies (38.5%), followed by the localisation of impacted teeth (33.1%). There was no relationship between sex and indications. There were significant associations between age groups and malocclusion and dentomaxillofacial anomalies, localisation of impacted teeth, and trauma. The face was the most frequently imaged region, followed by the jaws (maxilla and mandible). The most common indication for CBCT was malocclusion and dentomaxillofacial anomalies in the primary and permanent dentition age groups, whereas the localisation of impacted teeth was the most common indication in the mixed dentition age group. Generally, CBCT was indicated in orthodontics and surgery. © 2016 BSPD, IAPD and John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. Impact of Spot Size and Beam-Shaping Devices on the Treatment Plan Quality for Pencil Beam Scanning Proton Therapy

    International Nuclear Information System (INIS)

    Moteabbed, Maryam; Yock, Torunn I.; Depauw, Nicolas; Madden, Thomas M.; Kooy, Hanne M.; Paganetti, Harald

    2016-01-01

    Purpose: This study aimed to assess the clinical impact of spot size and the addition of apertures and range compensators on the treatment quality of pencil beam scanning (PBS) proton therapy and to define when PBS could improve on passive scattering proton therapy (PSPT). Methods and Materials: The patient cohort included 14 pediatric patients treated with PSPT. Six PBS plans were created and optimized for each patient using 3 spot sizes (∼12-, 5.4-, and 2.5-mm median sigma at isocenter for 90- to 230-MeV range) and adding apertures and compensators to plans with the 2 larger spots. Conformity and homogeneity indices, dose-volume histogram parameters, equivalent uniform dose (EUD), normal tissue complication probability (NTCP), and integral dose were quantified and compared with the respective PSPT plans. Results: The results clearly indicated that PBS with the largest spots does not necessarily offer a dosimetric or clinical advantage over PSPT. With comparable target coverage, the mean dose (D mean ) to healthy organs was on average 6.3% larger than PSPT when using this spot size. However, adding apertures to plans with large spots improved the treatment quality by decreasing the average D mean and EUD by up to 8.6% and 3.2% of the prescribed dose, respectively. Decreasing the spot size further improved all plans, lowering the average D mean and EUD by up to 11.6% and 10.9% compared with PSPT, respectively, and eliminated the need for beam-shaping devices. The NTCP decreased with spot size and addition of apertures, with maximum reduction of 5.4% relative to PSPT. Conclusions: The added benefit of using PBS strongly depends on the delivery configurations. Facilities limited to large spot sizes (>∼8 mm median sigma at isocenter) are recommended to use apertures to reduce treatment-related toxicities, at least for complex and/or small tumors.

  12. Assessment of quality indicators in spanish higher military education

    Directory of Open Access Journals (Sweden)

    Olmos Gómez Maria del Carmen

    2016-01-01

    Full Text Available The quality assessment is subject to multiple interpretations of its content and purpose, and also regarding to methods and techniques used to develop it. Although purposes of assessment are varied, usually pursuit three goals: Improvement, accountability and information. Currently, the concept of quality evaluation has been replaced by the management of educational quality, as Matthew [6] point “the new culture of evaluation is no longer oriented to penalty, ranking or selection of people, as provide a reasoned and reasonable information to guide the management of educational improvement”. Military Training Centres are externally evaluated by an experts External Evaluation Unit to identify strengths and weaknesses on their self-evaluation system and focus on important aspects related to the organization of the Centre, development of work plans, teacher’s style and students learning strategies, system of evaluation and qualification and accurate recommendations to improve all that. This research focuses on the evaluation of quality indicators for the external evaluation of higher education at Military Education Centres in Spain and it is funded by a joint project between University of Granada and MADOC. The technique used for collecting and analysing information was a content description of several documents provided by these military educational authorities, arising the identification and extraction of relevant indicators on the evaluation of higher education. This analysis was primarily based on standards and indicators systems by ANECA (National Agency for Quality Assessment and Accreditation adapted to the Military Higher Education, but also it was consider other standards by international agencies and evaluative institutions, such as University of Chile, University of Paraguay, Canarias Agency for Quality Assessment and Accreditation and Agency for Quality Education System University of Castilla y León. The analysis realize a usual

  13. Assessment of quality indicators in Spanish higher military education

    Directory of Open Access Journals (Sweden)

    Olmos Gómez Maria del Carmen

    2016-01-01

    Full Text Available The quality assessment is subject to multiple interpretations of its content and purpose, and also regarding to methods and techniques used to develop it. Although purposes of assessment are varied, usually pursuit three goals: Improvement, accountability and information. Currently, the concept of quality evaluation has been replaced by the management of educational quality, as Matthew [6] point “the new culture of evaluation is no longer oriented to penalty, ranking or selection of people, as provide a reasoned and reasonable information to guide the management of educational improvement”. Military Training Centres are externally evaluated by an experts External Evaluation Unit to identify strengths and weaknesses on their self-evaluation system and focus on important aspects related to the organization of the Centre, development of work plans, teacher’s style and students learning strategies, system of evaluation and qualification and accurate recommendations to improve all that. This research focuses on the evaluation of quality indicators for the external evaluation of higher education at Military Education Centres in Spain and it is funded by a joint project between University of Granada and MADOC. The technique used for collecting and analysing information was a content description of several documents provided by these military educational authorities, arising the identification and extraction of relevant indicators on the evaluation of higher education. This analysis was primarily based on standards and indicators systems by ANECA (National Agency for Quality Assessment and Accreditation adapted to the Military Higher Education, but also it was consider other standards by international agencies and evaluative institutions, such as University of Chile, University of Paraguay, Canarias Agency for Quality Assessment and Accreditation and Agency for Quality Education System University of Castilla y León. The analysis realize a usual

  14. A Framework of Quality Indicators for Learning Analytics

    NARCIS (Netherlands)

    Scheffel, Maren

    2017-01-01

    The LACE project has established a first version of a framework of quality indicators for learning analytics, based on a group concept mapping study with experts. The group concept mapping approach is explained, and steps in the framework creation process described, as well as the framework itself.

  15. Development of guideline-based quality indicators for recurrent miscarriage

    NARCIS (Netherlands)

    van den Boogaard, E.; Goddijn, M.; Leschot, N. J.; Veen, F. van der; Kremer, J. A. M.; Hermens, R. P. M. G.

    2010-01-01

    Recurrent miscarriage (RM) is a multifactorial clinical problem. Guidelines have been published to guide evidence-based clinical practice in RM. To measure adherence to these guidelines in daily practice and to monitor quality of care delivered in RM patients, indicators are necessary. This study

  16. Development of guideline-based quality indicators for recurrent miscarriage.

    NARCIS (Netherlands)

    Boogaard, E. van den; Goddijn, M.; Leschot, N.J.; Veen, F. van der; Kremer, J.A.M.; Hermens, R.P.M.G.

    2010-01-01

    Recurrent miscarriage (RM) is a multifactorial clinical problem. Guidelines have been published to guide evidence-based clinical practice in RM. To measure adherence to these guidelines in daily practice and to monitor quality of care delivered in RM patients, indicators are necessary. This study

  17. Quality indicators for passport data in ex situ genebanks

    NARCIS (Netherlands)

    Hintum, van T.J.L.; Menting, F.B.J.; Strien, van E.A.

    2011-01-01

    Given the increasing importance of data quality for the ex situ conservation and utilization of plant genetic resources (PGR), an indicator was created that quantifies the level of completeness of passport data. This passport data completeness index (PDCI) uses the presence or absence of data points

  18. The determination of beam quality correction factors: Monte Carlo simulations and measurements.

    Science.gov (United States)

    González-Castaño, D M; Hartmann, G H; Sánchez-Doblado, F; Gómez, F; Kapsch, R-P; Pena, J; Capote, R

    2009-08-07

    Modern dosimetry protocols are based on the use of ionization chambers provided with a calibration factor in terms of absorbed dose to water. The basic formula to determine the absorbed dose at a user's beam contains the well-known beam quality correction factor that is required whenever the quality of radiation used at calibration differs from that of the user's radiation. The dosimetry protocols describe the whole ionization chamber calibration procedure and include tabulated beam quality correction factors which refer to 60Co gamma radiation used as calibration quality. They have been calculated for a series of ionization chambers and radiation qualities based on formulae, which are also described in the protocols. In the case of high-energy photon beams, the relative standard uncertainty of the beam quality correction factor is estimated to amount to 1%. In the present work, two alternative methods to determine beam quality correction factors are prescribed-Monte Carlo simulation using the EGSnrc system and an experimental method based on a comparison with a reference chamber. Both Monte Carlo calculations and ratio measurements were carried out for nine chambers at several radiation beams. Four chamber types are not included in the current dosimetry protocols. Beam quality corrections for the reference chamber at two beam qualities were also measured using a calorimeter at a PTB Primary Standards Dosimetry Laboratory. Good agreement between the Monte Carlo calculated (1% uncertainty) and measured (0.5% uncertainty) beam quality correction factors was obtained. Based on these results we propose that beam quality correction factors can be generated both by measurements and by the Monte Carlo simulations with an uncertainty at least comparable to that given in current dosimetry protocols.

  19. Sterols indicate water quality and wastewater treatment efficiency.

    Science.gov (United States)

    Reichwaldt, Elke S; Ho, Wei Y; Zhou, Wenxu; Ghadouani, Anas

    2017-01-01

    As the world's population continues to grow, water pollution is presenting one of the biggest challenges worldwide. More wastewater is being generated and the demand for clean water is increasing. To ensure the safety and health of humans and the environment, highly efficient wastewater treatment systems, and a reliable assessment of water quality and pollutants are required. The advance of holistic approaches to water quality management and the increasing use of ecological water treatment technologies, such as constructed wetlands and waste stabilisation ponds (WSPs), challenge the appropriateness of commonly used water quality indicators. Instead, additional indicators, which are direct measures of the processes involved in the stabilisation of human waste, have to be established to provide an in-depth understanding of system performance. In this study we identified the sterol composition of wastewater treated in WSPs and assessed the suitability of human sterol levels as a bioindicator of treatment efficiency of wastewater in WSPs. As treatment progressed in WSPs, the relative abundance of human faecal sterols, such as coprostanol, epicoprostanol, 24-ethylcoprostanol, and sitostanol decreased significantly and the sterol composition in wastewater changed significantly. Furthermore, sterol levels were found to be correlated with commonly used wastewater quality indicators, such as BOD, TSS and E. coli. Three of the seven sterol ratios that have previously been used to track sewage pollution in the environment, detected a faecal signal in the effluent of WSPs, however, the others were influenced by high prevalence of sterols originating from algal and fungal activities. This finding poses a concern for environmental assessment studies, because environmental pollution from waste stabilisation ponds can go unnoticed. In conclusion, faecal sterols and their ratios can be used as reliable indicators of treatment efficiency and water quality during wastewater

  20. Feasibility of using a dose-area product ratio as beam quality specifier for photon beams with small field sizes.

    Science.gov (United States)

    Pimpinella, Maria; Caporali, Claudio; Guerra, Antonio Stefano; Silvi, Luca; De Coste, Vanessa; Petrucci, Assunta; Delaunay, Frank; Dufreneix, Stéphane; Gouriou, Jean; Ostrowsky, Aimé; Rapp, Benjamin; Bordy, Jean-Marc; Daures, Josiane; Le Roy, Maïwenn; Sommier, Line; Vermesse, Didier

    2018-01-01

    To investigate the feasibility of using the ratio of dose-area product at 20 cm and 10 cm water depths (DAPR 20,10 ) as a beam quality specifier for radiotherapy photon beams with field diameter below 2 cm. Dose-area product was determined as the integral of absorbed dose to water (D w ) over a surface larger than the beam size. 6 MV and 10 MV photon beams with field diameters from 0.75 cm to 2 cm were considered. Monte Carlo (MC) simulations were performed to calculate energy-dependent dosimetric parameters and to study the DAPR 20,10 properties. Aspects relevant to DAPR 20,10 measurement were explored using large-area plane-parallel ionization chambers with different diameters. DAPR 20,10 was nearly independent of field size in line with the small differences among the corresponding mean beam energies. Both MC and experimental results showed a dependence of DAPR 20,10 on the measurement setup and the surface over which D w is integrated. For a given setup, DAPR 20,10 values obtained using ionization chambers with different air-cavity diameters agreed with one another within 0.4%, after the application of MC correction factors accounting for effects due to the chamber size. DAPR 20,10 differences among the small field sizes were within 1% and sensitivity to the beam energy resulted similar to that of established beam quality specifiers based on the point measurement of D w . For a specific measurement setup and integration area, DAPR 20,10 proved suitable to specify the beam quality of small photon beams for the selection of energy-dependent dosimetric parameters. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  1. Estimation of air quality by air pollution indices

    International Nuclear Information System (INIS)

    Liblik, Valdo; Kundel, Helmut

    1999-01-01

    A novel system for estimating the quality of atmospheric air in the over-ground air layer with the help of air pollution indices was developed. The method is based on a comparison of measured or calculated maximum short-term concentrations and average annual concentrations of pollutants with maximum permissible concentrations (with regard to human beings and vegetation). Special air quality estimation scales for residential areas and natural systems are presented. On the basis of the concentration of the substance under study zones of very high, high, rather high, moderate, low and very low air pollution were distinguished in the over-ground layer of the atmosphere. These are projected to land surface for landscape zonation. The application of the system of indices is demonstrated in the analysis of air quality for the towns of Kohtla-Jarve, Johvi and Kivioli (in 1997-1998). A comparative analysis of the air pollution zones distinguished on the basis of emissions and data from bio monitoring yielded satisfactory results. The system of air pollution indices developed enables to process the results of air monitoring in case of pollution fields of complicated composition so that the result for estimating the quality of ambient air in a residential area is easily understood by inhabitants and interpretable with the help of a special scale; analyse temporal changes in the quality of the air in towns, villages and other residential areas and use the results as basis for developing measures for reducing the pollution of ambient air; carry out zonation of large territories on the basis of air pollution levels (spatial air pollution zones are projected on the ground surface) and estimate air quality in places where air monitoring is lacking to forecast the possible effect of air pollution on natural systems (author)

  2. Definition of parameters for quality assurance of flattening filter free (FFF) photon beams in radiation therapy

    International Nuclear Information System (INIS)

    Fogliata, A.; Garcia, R.; Knöös, T.; Nicolini, G.; Clivio, A.; Vanetti, E.; Khamphan, C.; Cozzi, L.

    2012-01-01

    Purpose: Flattening filter free (FFF) beams generated by medical linear accelerators have recently started to be used in radiotherapy clinical practice. Such beams present fundamental differences with respect to the standard filter flattened (FF) beams, making the generally used dosimetric parameters and definitions not always viable. The present study will propose possible definitions and suggestions for some dosimetric parameters for use in quality assurance of FFF beams generated by medical linacs in radiotherapy. Methods: The main characteristics of the photon beams have been analyzed using specific data generated by a Varian TrueBeam linac having both FFF and FF beams of 6 and 10 MV energy, respectively. Results: Definitions for dose profile parameters are suggested starting from the renormalization of the FFF with respect to the corresponding FF beam. From this point the flatness concept has been translated into one of “unflatness” and other definitions have been proposed, maintaining a strict parallelism between FFF and FF parameter concepts. Conclusions: Ideas for quality controls used in establishing a quality assurance program when introducing FFF beams into the clinical environment are given here, keeping them similar to those used for standard FF beams. By following the suggestions in this report, the authors foresee that the introduction of FFF beams into a clinical radiotherapy environment will be as safe and well controlled as standard beam modalities using the existing guidelines.

  3. Implementation to spanish protocol of quality control of accelerators to daily control of electron beams

    International Nuclear Information System (INIS)

    Adaimi Hernandez, P.; Ramirez Ros, J. C.; Casa de Julian, M. A. de la; Clemente Gutierrez, F.; Cabello Murillo, E.; Diaz Fuente, R.; Ferrando Sanchez, A.

    2011-01-01

    A revised procedure for daily control of the electron beams to make measurements more meaningful physically, having a better reproducibility and more in line with the recommendations of the Spanish Protocol for Quality Control in Electron Linear Accelerators Clinical Use. The daily quality control beams of high energy electrons that had been done so far was the finding that the record of a series of measures (symmetry, uniformity, stability, energy, beam central dose) were within tolerance values established. The amendment is to check the beam quality by directly measuring changes in absorption depth at which the dose is reduced to half its maximum value, R50.

  4. [Indicators of healthcare quality in day surgery (2010-2012)].

    Science.gov (United States)

    Martínez Rodenas, F; Codina Grifell, J; Deulofeu Quintana, P; Garrido Corchón, J; Blasco Casares, F; Gibanel Garanto, X; Cuixart Vilamajó, L; de Haro Licer, J; Vazquez Dorrego, X

    2014-01-01

    Monitoring quality indicators in Ambulatory Surgery centers is fundamental in order to identify problems, correct them and prevent them. Given their large number, it is essential to select the most valid ones. The objectives of the study are the continuous improvement in the quality of healthcare of day-case surgery in our center, by monitoring selective quality parameters, having periodic information on the results and taking corrective measures, as well as achieving a percentage of unplanned transfer and cancellations within quality standards. Prospective, observational and descriptive study of the day-case surgery carried out from January 2010 to December 2012. Unplanned hospital admissions and cancellations on the same day of the operation were selected and monitored, along with their reasons. Hospital admissions were classified as: inappropriate selection, medical-surgical complications, and others. The results were evaluated each year and statistically analysed using χ(2) tests. A total of 8,300 patients underwent day surgery during the 3 years studied. The day-case surgery and outpatient index increased by 5.4 and 6.4%, respectively (P<.01). Unexpected hospital admissions gradually decreased due to the lower number of complications (P<.01). Hospital admissions, due to an extended period of time in locoregional anaesthesia recovery, also decreased (P<.01). There was improved prevention of nausea and vomiting, and of poorly controlled pain. The proportion of afternoon admissions was significantly reduced (P<.01). The cancellations increased in 2011 (P<.01). The monitoring of quality parameters in day-case surgery has been a useful tool in our clinical and quality management. Globally, the unplanned transfer and cancellations have been within the quality standards and many of the indicators analysed have improved. Copyright © 2013 SECA. Published by Elsevier Espana. All rights reserved.

  5. Experimental determination of beam quality factors, kQ, for two types of Farmer chamber in a 10 MV photon and a 175 MeV proton beam.

    Science.gov (United States)

    Medin, Joakim; Ross, Carl K; Klassen, Norman V; Palmans, Hugo; Grusell, Erik; Grindborg, Jan-Erik

    2006-03-21

    Absorbed doses determined with a sealed water calorimeter operated at 4 degrees C are compared with the results obtained using ionization chambers and the IAEA TRS-398 code of practice in a 10 MV photon beam (TPR(20,10) = 0.734) and a 175 MeV proton beam (at a depth corresponding to the residual range, R(res) = 14.7 cm). Three NE 2571 and two FC65-G ionization chambers were calibrated in terms of absorbed-dose-to-water in (60)Co at the Swedish secondary standard dosimetry laboratory, directly traceable to the BIPM. In the photon beam quality, calorimetry was found to agree with ionometry within 0.3%, confirming the k(Q) values tabulated in TRS-398. In contrast, a 1.8% deviation was found in the proton beam at 6 g cm(-2) depth, suggesting that the TRS-398 tabulated k(Q) values for these two ionization chamber types are too high. Assuming no perturbation effect in the proton beam for the ionization chambers, a value for (w(air)/e)(Q) of 33.6 J C(-1) +/- 1.7% (k = 1) can be derived from these measurements. An analytical evaluation of the effect from non-elastic nuclear interactions in the ionization chamber wall indicates a perturbation effect of 0.6%. Including this estimated result in the proton beam would increase the determined (w(air)/e)(Q) value by the same amount.

  6. Assessing quality in European educational research indicators and approaches

    CERN Document Server

    Åström, Fredrik; Hansen, Antje

    2014-01-01

    Competition-based models for research policy and management have an increasing influence throughout the research process, from attracting funding to publishing results. The introduction of quality control methods utilizing various forms of performance indicators is part of this development. The authors presented in this volume deal with the following questions: What counts as ‘quality’ and how can this be assessed? What are the possible side effects of current quality control systems on research conducted in the European Research Area, especially in the social sciences and the humanities?

  7. UK key performance indicators and quality assurance standards for colonoscopy.

    Science.gov (United States)

    Rees, Colin J; Thomas Gibson, Siwan; Rutter, Matt D; Baragwanath, Phil; Pullan, Rupert; Feeney, Mark; Haslam, Neil

    2016-12-01

    Colonoscopy should be delivered by endoscopists performing high quality procedures. The British Society of Gastroenterology, the UK Joint Advisory Group on GI Endoscopy, and the Association of Coloproctology of Great Britain and Ireland have developed quality assurance measures and key performance indicators for the delivery of colonoscopy within the UK. This document sets minimal standards for delivery of procedures along with aspirational targets that all endoscopists should aim for. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  8. [Quality improvement in primary care. Financial incentives related to quality indicators in Europe].

    Science.gov (United States)

    Kolozsvári, László Róbert; Rurik, Imre

    2013-07-14

    Quality improvement in primary care has been an important issue worldwide for decades. Quality indicators are increasingly used quantitative tools for quality measurement. One of the possible motivational methods for doctors to provide better medical care is the implementation of financial incentives, however, there is no sufficient evidence to support or contradict their effect in quality improvement. Quality indicators and financial incentives are used in the primary care in more and more European countries. The authors provide a brief update on the primary care quality indicator systems of the United Kingdom, Hungary and other European countries, where financial incentives and quality indicators were introduced. There are eight countries where quality indicators linked to financial incentives are used which can influence the finances/salary of family physicians with a bonus of 1-25%. Reliable data are essential for quality indicators, although such data are lacking in primary care of most countries. Further, improvement of indicator systems should be based on broad professional consensus.

  9. Analysis of ion beam teletherapy patient-specific quality assurance.

    Science.gov (United States)

    Liu, Xiaoli; Deng, Yu; Schlegel, Nicki; Huang, Zhijie; Moyers, Michael F

    2018-02-27

    The objective of this study was to evaluate the procedures for patient-specific quality assurance measurements using modulated scanned and energy stacked beams for proton and carbon ion teletherapy. Delivery records from 1734 portal measurements were analyzed using a 3-point pass criteria: more than 22 of 24 chambers in a water phantom (WP) had to have a measured dose difference from the planned portal doses less than or equal to 3%, or the distance from the measurement point location to a point location in the plan having the same dose had to be less than or equal to 3 mm (distance to agreement [DTA]), and the mean dose deviation of all chambers had to be less than 3%. Stratification of results showed some associations between measurement parameters and pass rates. For proton portals, pass rates were high at all measurement depths, but for carbon ion portals, pass rates decreased as a function of increasing measurement depth. Pass rates of both proton and carbon ion portals with 1 WP were slightly lower than those with a second WP. The total pass rates were 97.7% and 91.9% for proton and carbon ion patient portals, respectively. In general, the measured doses exhibited good agreement with the treatment planning system (TPS) calculated doses. When the chamber position was deeper than 150 mm in carbon ion beams, a lower pass rate was observed, which may have been caused by ion chamber array setup uncertainty (lateral and depth) in highly modulated portals or incorrect modeling of scatter by the TPS. These deviations need further investigation. Copyright © 2018 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  10. A simple method for boosting the beam quality of commercial DPL

    Science.gov (United States)

    Zhang, Guang-Yin; Jiao, Zhi-Yong; Yan, Cai-Fan; Ding, Xin; Zhang, Chao-Bo; Zhang, Xiao-Hua; Gu, Xue-Wen; Song, Feng

    2003-12-01

    A simple method for boosting the beam quality of a commercial laser diode pumped laser (DPL) is put forward. By keeping one of the mirrors unchanged and the moving the other mirror a proper distance away from the laser rod, high beam quality laser output is realized.

  11. Biological and biochemical soil quality indicators for agricultural management

    Science.gov (United States)

    Bongiorno, Giulia

    2017-04-01

    Soil quality is defined as the capacity of a soil to perform multiple functions. Agricultural soils can, in principle, sustain a wide range of functions. However, negative pressure exerted by natural and anthropogenic soil threats such as soil erosion, soil organic matter losses and soil compaction have the potential to permanently damage soil quality. Soil chemical, physical and biological parameters can be used as indicators of soil quality. The specific objective of this study is to assess the suitability of novel soil parameters as soil quality indicators. We focus on biological/biochemical parameters, due to the unique role of soil biota in soil functions and to their high sensitivity to disturbances. The novel indicators are assessed in ten European long-term field experiments (LTEs) with different agricultural land use (arable and permanent crops), management regimes and pedo-climatic characteristics. The contrasts in agricultural management are represented by conventional/reduced tillage, organic/mineral fertilization and organic matter addition/no organic matter addition. We measured two different pools of labile organic carbon (dissolved organic carbon (DOC), and permanganate oxidizable carbon (POXC)), and determined DOC quality through its fractionation in hydrophobic and hydrophilic compounds. In addition, total nematode abundance has been assessed with qPCR. These parameters will be related to soil functions which have been measured with a minimum data set of indicators for soil quality (including TOC, macronutrients, and soil respiration). As a preliminary analysis, the Sensitivity Index (SI) for a given LTE was calculated for DOC and POXC according to Bolinder et al., 1999 as the ratio of the soil attribute under modified practices (e.g. reduced tillage) compared to the conventional practices (e.g. conventional tillage). The overall effect of the sustainable management on the indicators has been derived by calculating an average SI for those LTEs

  12. Survey of quality indicators in commercial dehydrated fruits.

    Science.gov (United States)

    Megías-Pérez, Roberto; Gamboa-Santos, Juliana; Soria, Ana Cristina; Villamiel, Mar; Montilla, Antonia

    2014-05-01

    Physical and chemical quality parameters (dry matter, aw, protein, carbohydrates, vitamin C, 2-furoylmethyl amino acids, rehydration ratio and leaching loss) have been determined in 30 commercial dehydrated fruits (strawberry, blueberry, raspberry, cranberry, cherry, apple, grapefruit, mango, kiwifruit, pineapple, melon, coconut, banana and papaya). For comparison purposes, strawberry samples processed in the laboratory by freeze-drying and by convective drying were used as control samples. Overall quality of dehydrated fruits seemed to be greatly dependent on processing conditions and, in a cluster analysis, samples which were presumably subjected to osmotic dehydration were separated from the rest of fruits. These samples presented the lowest concentration of vitamin C and the highest evolution of Maillard reaction, as evidenced by its high concentration of 2-furoylmethyl amino acids. This is the first study on the usefulness of this combination of chemical and physical indicators to assess the overall quality of commercial dehydrated fruits. Copyright © 2013 Elsevier Ltd. All rights reserved.

  13. An international environmental scan of quality indicators for cardiovascular care.

    Science.gov (United States)

    Abrahamyan, Lusine; Boom, Nicole; Donovan, Linda R; Tu, Jack V

    2012-01-01

    Quality indicators (QIs) are increasingly being used to measure and improve the quality of cardiac care. We conducted an international environmental scan to identify and critically appraise published QI development initiatives addressing cardiovascular disease (CVD). A review of the peer-reviewed and grey English-language literature was conducted to identify published CVD QI development initiatives. The quality of identified studies was assessed using a modified version of the Appraisal of Guidelines for Research and Evaluation (AGREE) II QI tool-an instrument originally developed for the assessment of the quality of clinical practice guidelines. An initial literature search identified 2314 potentially relevant abstracts of peer-reviewed articles. After a review of the abstracts, 120 full text articles were retrieved and reviewed. Of these, 20 articles and 1 peer-reviewed monograph were selected for critical appraisal (n = 21). Most of the initiatives were conducted in North America (76%) and were published after 2005 (62%). The majority (5 of 6) of the AGREE II QI domain scores were skewed toward higher values, including the median score for the 'overall quality' rating (83.3%). Of the CVD categories addressed within the 21 initiatives, heart failure was the most common (n = 10 QI indicator sets), followed by acute coronary syndromes (n = 8). Considerable variation was observed in the methods utilized and the degree of scientific rigour applied in the published international CVD QI development initiatives. Adoption of standardized methods could help improve the quality of QI development initiatives. Copyright © 2012 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  14. Health indicators associated with poor sleep quality among university students

    Directory of Open Access Journals (Sweden)

    Márcio Flávio Moura de Araújo

    Full Text Available Objective To associate the sleep quality of Brazilian undergraduate students with health indicators. Method A cross-sectional study was developed with a random sample of 662 undergraduate students from Fortaleza, Brazil. The demographic data, Pittsburgh Sleep Quality Index and health data indicators (smoking, alcoholism, sedentary lifestyle, nutritional condition and serum cholesterol were collected through a self-administered questionnaire. Blood was collected at a clinical laboratory. In order to estimate the size of the associations, a Poisson Regression was used. Results For students who are daily smokers, the occurrence of poor sleep was higher than in non-smokers (p<0.001. Prevalence rate values were nevertheless close to 1. Conclusion The likelihood of poor sleep is almost the same in smokers and in alcoholics.

  15. Water quality assessment of Australian ports using water quality evaluation indices

    OpenAIRE

    Jahan, Sayka; Strezov, Vladimir

    2017-01-01

    Australian ports serve diverse and extensive activities, such as shipping, tourism and fisheries, which may all impact the quality of port water. In this work water quality monitoring at different ports using a range of water quality evaluation indices was applied to assess the port water quality. Seawater samples at 30 stations in the year 2016-2017 from six ports in NSW, Australia, namely Port Jackson, Botany, Kembla, Newcastle, Yamba and Eden, were investigated to determine the physicochem...

  16. Quality indicators in a newborn hearing screening service.

    Science.gov (United States)

    Januário, Gabriela Cintra; Lemos, Stela Maris Aguiar; Friche, Amélia Augusta de Lima; Alves, Claudia Regina Lindgren

    2015-01-01

    Newborn hearing screening (NHS) programs are implemented across the globe to detect early hearing impairment. In order to meet this objective, the quality of these programs should be monitored using internationally recognized indicators. To evaluate a newborn hearing screening service (NHSS) using international quality indicators. A retrospective cohort study on the NHSS of Minas Gerais was conducted, analyzing the services performed between 2010 and 2011. Results were analyzed according to criteria from the American Academy of Pediatrics and the Joint Committee on Infant Hearing. This study assessed 6987 children. The proportions of cases that were referred for a retest, that followed through with retest, and that were referred for diagnosis were 8.0%, 71.9%, and 2.1%, respectively. The proportion of assessed newborn children in the first 30 days of life in this study was 65%. The median age of those children who failed both the NHS and the retest was significantly higher than the other children. The chance of a child with a hearing impairment risk indicator to fail the NHS was 2.4 times higher than of those without a risk indicator. NHSS achieved three of four evaluated indicators. Despite this, it is still necessary to perform NHS earlier and to ensure that the subsequent steps are followed. Copyright © 2014 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  17. Physical soil quality indicators for monitoring British soils

    Directory of Open Access Journals (Sweden)

    R. Corstanje

    2017-09-01

    Full Text Available Soil condition or quality determines its ability to deliver a range of functions that support ecosystem services, human health and wellbeing. The increasing policy imperative to implement successful soil monitoring programmes has resulted in the demand for reliable soil quality indicators (SQIs for physical, biological and chemical soil properties. The selection of these indicators needs to ensure that they are sensitive and responsive to pressure and change, e.g. they change across space and time in relation to natural perturbations and land management practices. Using a logical sieve approach based on key policy-related soil functions, this research assessed whether physical soil properties can be used to indicate the quality of British soils in terms of their capacity to deliver ecosystem goods and services. The resultant prioritised list of physical SQIs was tested for robustness, spatial and temporal variability, and expected rate of change using statistical analysis and modelling. Seven SQIs were prioritised: soil packing density, soil water retention characteristics, aggregate stability, rate of soil erosion, depth of soil, soil structure (assessed by visual soil evaluation and soil sealing. These all have direct relevance to current and likely future soil and environmental policy and are appropriate for implementation in soil monitoring programmes.

  18. Selection indices for yield and quality traits in sweet corn

    International Nuclear Information System (INIS)

    Asghar, M.J.; Mehdi, S.S.

    2010-01-01

    The efficiency of three selection indices, viz., Smith-Hazel index (SHI), Desired gain index (DGI) and Base Index (BI) was compared for the improvement of an open pollinated sweet corn (Zea mays L. Saccharata) population. The data of genetic studies on various yield and quality traits among S1 families were used to construct these selection indices. Smith-Hazel index was found to be the most efficient in improving the aggregate genotype of yield traits for most of the selection strategies. Base index proved to be more efficient as compared to Smith-Hazel index in the improvement of aggregate genotype for five out of six selection strategies of quality traits. Both smith-hazel and Base indices were found useful for the improvement of sweetness and sweet flavour for all the selection strategies. When selection was confined to eight yield and four quality traits simultaneously, Base index proved to be more efficient as compared to Smith-Hazel index and desired gain index in improving the aggregate genotype for almost all the selection strategies. (author)

  19. Amino acid quality indices of the leaves of Clerodendrum volubile

    Directory of Open Access Journals (Sweden)

    Ochuko Lucky Erukainure

    2016-04-01

    Full Text Available Objective: To evaluate the amino acid profile and quality indices of Clerodendrum volubile (C. volubile leaves. Methods: Dried leaves of C. volubile were blended, defatted and subjected to amino acid analysis using the technicon sequential multi-sample amino acid analyzer. The amino acid quality indices which covers for chemical score, essential amino acid index, nutritional index, true digestibility, protein digestibility corrected amino acid score, and digestible indispensable amino acid score were evaluated using standard formulas. Results: Amino acid analysis revealed glutamic acid to have the highest concentration, with cysteine having the least. Aspartic acid had the highest chemical score, this was followed by glycine, histidine and arginine, respectively. The least scores were observed in serine and methionine. Glutamic acid had the highest value for true digestibility and protein digestibility corrected amino acid score, with the least observed in cysteine. Digestible indispensable amino acid score evaluation showed histidine to have the highest value for infants (birth to 6 months, threonine for children (6 months to 3 years, while isoleucine was observed to have the highest value for older children, adolescents and adults. The essential amino acid index value was less than 4, while nutritional index value was less than 0.5. Conclusions: These results indicated the leaves of C. volubile as a potential source of amino acids in the human diet as portrayed by its amino acids profile and qualities.

  20. Dosimetric study of RapidArc plans with flattened beam (FB and flattening filter-free (FFF beam for localized prostate cancer based on physical indices

    Directory of Open Access Journals (Sweden)

    Birendra Kumar Rout

    2014-12-01

    Full Text Available Purpose: To identify the continual diversity between flattening photon beam (FB and Flattening Filter Free (FFF photon beams for localized prostate cancer; and to determine potential benefits and drawbacks of using unflattened beam for this type of treatment.Methods: Eight prostate cases including seminal vesicles selected for this study. The primary planning target volume (PTVP and boost planning target volume (PTVB were contoured. The total prescription dose was 78 Gy (56 Gy to PTVP and an additional 22 Gy to PTVB. For all cases, treatment plans using 6MV with FB and FFF beams with identical dose-volume constraints, arc angles and number of arcs were developed. The dose volume histograms for both techniques were compared for primary target volume and critical structures.Results: A low Sigma index (FFF: 1.65 + 0.361; FB: 1.725 + 0.39 indicating improved dose homogeneity in FFF beam. Conformity index (FFF: 0.994 + 0.01; FB: 0.993 + 0.01 is comparable for both techniques. Minimal difference of Organ at risk mean dose was observed. Normal tissue integral dose in FB plan resulted 1.5% lower than FFF plan. All the plans displayed significant increase (1.18 times for PTVP and 1.11 for PTBB in the average number of necessary MU with FFF beam.Conclusion: Diversity between FB and FFF beam plans were found. FFF beam accelerator has been utilized to develop clinically acceptable Rapid Arc treatment plans for prostate cancer with 6 MV.---------------------------------Cite this article as: Rout BK, Muralidhar KR, Ali M, Shekar MC, Kumar A. Dosimetric study of RapidArc plans with flattened beam (FB and flattening filter-free (FFF beam for localized prostate cancer based on physical indices. Int J Cancer Ther Oncol 2014; 2(4:02046.  DOI: 10.14319/ijcto.0204.6

  1. [Quality indicators for surgery of rectal cancer : Evidence-based development of a set of indicators for quality].

    Science.gov (United States)

    Wiegering, A; Buhr, H-J; Klinger, C; Fürst, A; Schiedeck, T; Schwandner, O; Stelzner, S; Germer, C-T

    2018-01-01

    The definition of valid quality indicators is an essential task of medical self-administration and quality assurance. Based on the literature and the results of the Study, Documentation, and Quality Center (StuDoQ) Rectal Cancer Registry, we suggest the following QIs: rate of circumferential resection margin (CRM) positive resected material, rate of anastomotic leak in patients with anastomoses, rate of abdominal wound healing disorders and rate of patients with newly established permanent urinary diversion. Additionally, a new marker, the MTL30, which subsumes patient death within 30 days after the index operation, patient transfer to another acute hospital within 30 days after the index operation or a length of inpatient hospital stay of more than 30 days.

  2. Measuring the quality of pressure ulcer prevention: A systematic mapping review of quality indicators.

    Science.gov (United States)

    Kottner, Jan; Hahnel, Elisabeth; Lichterfeld-Kottner, Andrea; Blume-Peytavi, Ulrike; Büscher, Andreas

    2017-11-27

    The aim of this study was to provide a systematic overview of available pressure ulcer prevention quality indicators and to evaluate the underlying empirical evidence. A systematic mapping review was conducted with combined searches in Embase and Medline, and websites of relevant institutions and organisations. The eligibility criteria were clear use of the term "quality indicator" regarding pressure ulcer prevention; English or German language; and all settings, populations, and types of resources, including articles, brochures, and online material. In total, n = 146 quality indicators were identified. Most indicators were published in the United States (n = 50). The majority of indicators was developed for the hospital setting (n = 102). Process indicators were the most common (n = 71), followed by outcome indicators (n = 49). Less than half of identified indicators appeared to be practically used. Evidence supporting the validity and reliability were reported for n = 25 and n = 30 indicators respectively. The high number of indicators demonstrate the importance of measuring pressure ulcer prevention quality. This is not an indicator of our ability to accurately measure and evaluate this construct. There is an urgent need to develop evidence-based and internationally comparable indicators to help improve patient care and safety worldwide. © 2017 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  3. Health-related quality of life: an indicator of quality of care?

    NARCIS (Netherlands)

    Treurniet, H. F.; Essink-Bot, M. L.; Mackenbach, J. P.; van der Maas, P. J.

    1997-01-01

    There is an increasing interest in the use of outcome indicators to monitor the quality of care. Traditionally, outcome indicators have been based mainly on biological indicators reflecting death or disease. Now that various instruments for health status measurement have become available, questions

  4. Impact of large x-ray beam collimation on image quality

    Science.gov (United States)

    Racine, Damien; Ba, Alexandre; Ott, Julien G.; Bochud, François O.; Verdun, Francis R.

    2016-03-01

    Large X-ray beam collimation in computed tomography (CT) opens the way to new image acquisition techniques and improves patient management for several clinical indications. The systems that offer large X-ray beam collimation enable, in particular, a whole region of interest to be investigated with an excellent temporal resolution. However, one of the potential drawbacks of this option might be a noticeable difference in image quality along the z-axis when compared with the standard helical acquisition mode using more restricted X-ray beam collimations. The aim of this project is to investigate the impact of the use of large X-ray beam collimation and new iterative reconstruction on noise properties, spatial resolution and low contrast detectability (LCD). An anthropomorphic phantom and a custom made phantom were scanned on a GE Revolution CT. The images were reconstructed respectively with ASIR-V at 0% and 50%. Noise power spectra, to evaluate the noise properties, and Target Transfer Functions, to evaluate the spatial resolution, were computed. Then, a Channelized Hotelling Observer with Gabor and Dense Difference of Gaussian channels was used to evaluate the LCD using the Percentage correct as a figure of merit. Noticeable differences of 3D noise power spectra and MTF have been recorded; however no significant difference appeared when dealing with the LCD criteria. As expected the use of iterative reconstruction, for a given CTDIvol level, allowed a significant gain in LCD in comparison to ASIR-V 0%. In addition, the outcomes of the NPS and TTF metrics led to results that would contradict the outcomes of CHO model observers if used for a NPWE model observer (Non- Prewhitening With Eye filter). The unit investigated provides major advantages for cardiac diagnosis without impairing the image quality level of standard chest or abdominal acquisitions.

  5. Performance indicators: A tool for continuous quality improvement

    Directory of Open Access Journals (Sweden)

    Nidhi M Bhatnagar

    2016-01-01

    Full Text Available Background: Performance monitoring is an important tool which can be used for setting priorities for process improvement. At our centre, we have been monitoring every step in the processes, right from inventory of consumables (both critical and routine to number of donors reactive for TTI. We conducted a study to measure the impact of monitoring Performance Indicators and how it could be used as a tool for Continuous Quality Improvement (CQI. Materials and Methods: The present study was a retrospective study where the performance indicator (PI data of blood bank was analyzed for over four years. For certain parameters, benchmarks or thresholds were set that represented warning limits or action limits. The yearly data were collated from monthly data. "Shifts" or "Trends", if any, were identified and Corrective and Preventive Action (CAPA taken accordingly. At the end, outcomes of the analysis were charted. Results: After the yearly data evaluation, outcomes obtained were used to plan, correct and amend processes and systems in the blood center. It was observed that the workload of the center showed an upward trend. This helped us to plan for the purchase of consumables and management of manpower. The monitoring of usage and discard of blood helped in the efficient management of blood stocks. The need for any new equipment could also be judged by the trends in workload. Conclusion: Performance indicators are indispensible tools which various stakeholders in the Blood Transfusion centres should implement to improve on quality performance.

  6. Performance indicators: A tool for continuous quality improvement.

    Science.gov (United States)

    Bhatnagar, Nidhi M; Soni, Shital; Gajjar, Maitrey; Shah, Mamta; Shah, Sangita; Patel, Vaidehi

    2016-01-01

    Performance monitoring is an important tool which can be used for setting priorities for process improvement. At our centre, we have been monitoring every step in the processes, right from inventory of consumables (both critical and routine) to number of donors reactive for TTI. We conducted a study to measure the impact of monitoring Performance Indicators and how it could be used as a tool for Continuous Quality Improvement (CQI). The present study was a retrospective study where the performance indicator (PI) data of blood bank was analyzed for over four years. For certain parameters, benchmarks or thresholds were set that represented warning limits or action limits. The yearly data were collated from monthly data. Shifts or Trends, if any, were identified and Corrective and Preventive Action (CAPA) taken accordingly. At the end, outcomes of the analysis were charted. After the yearly data evaluation, outcomes obtained were used to plan, correct and amend processes and systems in the blood center. It was observed that the workload of the center showed an upward trend. This helped us to plan for the purchase of consumables and management of manpower. The monitoring of usage and discard of blood helped in the efficient management of blood stocks. The need for any new equipment could also be judged by the trends in workload. Performance indicators are indispensible tools which various stakeholders in the Blood Transfusion centres should implement to improve on quality performance.

  7. A cluster-randomised quality improvement study to improve two inpatient stroke quality indicators.

    Science.gov (United States)

    Williams, Linda; Daggett, Virginia; Slaven, James E; Yu, Zhangsheng; Sager, Danielle; Myers, Jennifer; Plue, Laurie; Woodward-Hagg, Heather; Damush, Teresa M

    2016-04-01

    Quality indicator collection and feedback improves stroke care. We sought to determine whether quality improvement training plus indicator feedback was more effective than indicator feedback alone in improving inpatient stroke indicators. We conducted a cluster-randomised quality improvement trial, randomising hospitals to quality improvement training plus indicator feedback versus indicator feedback alone to improve deep vein thrombosis (DVT) prophylaxis and dysphagia screening. Intervention sites received collaborative-based quality improvement training, external facilitation and indicator feedback. Control sites received only indicator feedback. We compared indicators pre-implementation (pre-I) to active implementation (active-I) and post-implementation (post-I) periods. We constructed mixed-effect logistic models of the two indicators with a random intercept for hospital effect, adjusting for patient, time, intervention and hospital variables. Patients at intervention sites (1147 admissions), had similar race, gender and National Institutes of Health Stroke Scale scores to control sites (1017 admissions). DVT prophylaxis improved more in intervention sites during active-I period (ratio of ORs 4.90, pimproved similarly in both groups during active-I, but control sites improved more in post-I period (ratio of ORs 0.67, p=0.04). In logistic models, the intervention was independently positively associated with DVT performance during active-I period, and negatively associated with dysphagia performance post-I period. Quality improvement training was associated with early DVT improvement, but the effect was not sustained over time and was not seen with dysphagia screening. External quality improvement programmes may quickly boost performance but their effect may vary by indicator and may not sustain over time. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  8. The ESTRO-EQUAL quality assurance network for photon and electron radiotherapy beams in Germany

    International Nuclear Information System (INIS)

    Ferreira, I.H.; Dutreix, A.; Richter, J.; Bridier, A.; Chavaudra, J.; Svensson, H.

    2001-01-01

    Background: In 1998 an ESTRO Quality Assurance Network for radiotherapy (EQUAL) has been set up for 25 European countries for photon and electron beams in reference and non-reference conditions. Material and Methods: Measurements are done using LiF powder (DTL937-Philitech, France) that is processed with the PCL3 automatic reader (Fimel-PTW). The participating centers irradiate the TLDs with an absorbed dose of 2 Gy according to the clinical routine. Results: Until September 2000 EQUAL has checked 135 photon beams (including the beams rechecked) from 51 radiotherapy centers in Germany out of 86 accepted centers. The results show that 2% of the beam outputs in reference conditions and 3% of the percentage depth doses are outside the tolerance level (deviation > ± 5%). 6% of the beam output variations and of the wedge transmission factors show deviations > ± 5%. The global analysis of results shows deviations > ± 5% in at least one parameter for 18 beams out of the 135 beams checked. Five rechecked beams present one ''real dosimetric'' problem in one or more parameters, corresponding to 4% of the 114 beams for which the deviations cannot be attributed to set-up errors. - The EQUAL network has checked 89 electron beams in Germany. The results show that all beam outputs checked are within the tolerance level. The standard deviation for the beam output in reference conditions is 2.0% and 2.2% for the beam output for the others field sizes. The percentage of deviations > 3% and ≤ 5% for the reference beam output is higher for electron beams than for photon beam checks. Therefore the electron beam calibration and the TPS algorithms should be improved to increase the accuracy of the patient dosimetry for radiotherapy. (orig.) [de

  9. Water quality assessment of Australian ports using water quality evaluation indices

    Science.gov (United States)

    Jahan, Sayka

    2017-01-01

    Australian ports serve diverse and extensive activities, such as shipping, tourism and fisheries, which may all impact the quality of port water. In this work water quality monitoring at different ports using a range of water quality evaluation indices was applied to assess the port water quality. Seawater samples at 30 stations in the year 2016–2017 from six ports in NSW, Australia, namely Port Jackson, Botany, Kembla, Newcastle, Yamba and Eden, were investigated to determine the physicochemical and biological variables that affect the port water quality. The large datasets obtained were designed to determine the Water Quality Index, Heavy metal Evaluation Index, Contamination Index and newly developed Environmental Water Quality Index. The study revealed medium water quality index and high and medium heavy metal evaluation index at three of the study ports and high contamination index in almost all study ports. Low level dissolved oxygen and higher level of total dissolved solids, turbidity, fecal coliforms, copper, iron, lead, zinc, manganese, cadmium and cobalt are mainly responsible for the poor water qualities of the port areas. Good water quality at the background samples indicated that various port activities are the likely cause for poor water quality inside the port area. PMID:29244876

  10. Water quality assessment of Australian ports using water quality evaluation indices.

    Directory of Open Access Journals (Sweden)

    Sayka Jahan

    Full Text Available Australian ports serve diverse and extensive activities, such as shipping, tourism and fisheries, which may all impact the quality of port water. In this work water quality monitoring at different ports using a range of water quality evaluation indices was applied to assess the port water quality. Seawater samples at 30 stations in the year 2016-2017 from six ports in NSW, Australia, namely Port Jackson, Botany, Kembla, Newcastle, Yamba and Eden, were investigated to determine the physicochemical and biological variables that affect the port water quality. The large datasets obtained were designed to determine the Water Quality Index, Heavy metal Evaluation Index, Contamination Index and newly developed Environmental Water Quality Index. The study revealed medium water quality index and high and medium heavy metal evaluation index at three of the study ports and high contamination index in almost all study ports. Low level dissolved oxygen and higher level of total dissolved solids, turbidity, fecal coliforms, copper, iron, lead, zinc, manganese, cadmium and cobalt are mainly responsible for the poor water qualities of the port areas. Good water quality at the background samples indicated that various port activities are the likely cause for poor water quality inside the port area.

  11. Water quality assessment of Australian ports using water quality evaluation indices.

    Science.gov (United States)

    Jahan, Sayka; Strezov, Vladimir

    2017-01-01

    Australian ports serve diverse and extensive activities, such as shipping, tourism and fisheries, which may all impact the quality of port water. In this work water quality monitoring at different ports using a range of water quality evaluation indices was applied to assess the port water quality. Seawater samples at 30 stations in the year 2016-2017 from six ports in NSW, Australia, namely Port Jackson, Botany, Kembla, Newcastle, Yamba and Eden, were investigated to determine the physicochemical and biological variables that affect the port water quality. The large datasets obtained were designed to determine the Water Quality Index, Heavy metal Evaluation Index, Contamination Index and newly developed Environmental Water Quality Index. The study revealed medium water quality index and high and medium heavy metal evaluation index at three of the study ports and high contamination index in almost all study ports. Low level dissolved oxygen and higher level of total dissolved solids, turbidity, fecal coliforms, copper, iron, lead, zinc, manganese, cadmium and cobalt are mainly responsible for the poor water qualities of the port areas. Good water quality at the background samples indicated that various port activities are the likely cause for poor water quality inside the port area.

  12. Indicators of image quality and doses in mammography

    International Nuclear Information System (INIS)

    Gaona, E.; Franco E, J.G.; Azorin N, J.; Diaz G, J.A.I.; Arreola, M.

    2007-01-01

    Full text: The purpose of the study was to determine the values of the image quality indicators and their relationship with the dose in mammography of screen-film that they allowed the detection of a bigger number of objects in the images obtained with the mannequin (phantom) authorized of the ACR/FDA. The study was carried out in four mammography services in a period of 12 months. The indicators of the image quality are the half optic density (DOM), contrast (differences of densities), the number of observed objects in the images and the dose for image. The minimum acceptable values by the ACR/FDA are a half optical density of 1.4, contrast of 0.4 and the one numbers minimum of objects observed in the image of the mannequin of mammography of 10 (4 fibers, 3 groups of calcifications and 3 masses), with a maximum dose by image of 3 mGy. The found results are half optical density of 1.9, contrast of 0.56 and the average number of objects observed in the images of 12, with a dose in the interval of 1.6 mGy to 2.4 mGy. The doses were measured by thermoluminescent dosimetry and ionization chamber. Once carried out the analysis of the tendencies of the indicators of image quality and their distributions is found that for a p < 0.05, the bigger number of objects observed in the images is in the interval from 1.8 to 1.9 of DOM. When comparing both mammography system, the system screen-film has a lower variability in the distribution of objects associated to a DOM. (Author)

  13. Water quality evaluation of Al-Gharraf river by two water quality indices

    Science.gov (United States)

    Ewaid, Salam Hussein

    2017-11-01

    Water quality of Al-Gharraf river, the largest branch of Tigris River south of Iraq, was evaluated by the National Sanitation Foundation Water Quality Index (NFS WQI) and the Heavy Metal Pollution Index (HPI) depending on 13 physical, chemical, and biological parameters of water quality measured monthly at ten stations on the river during 2015. The NSF-WQI range obtained for the sampling sites was 61-70 indicating a medium water quality. The HPI value was 98.6 slightly below the critical value for drinking water of 100, and the water quality in the upstream stations is better than downstream due to decrease in water and the accumulation of contaminants along the river. This study explains the significance of applying the water quality indices that show the aggregate impact of ecological factors in charge of water pollution of surface water and which permits translation of the monitoring data to assist the decision makers.

  14. Improvement of the beam quality of a broad-area diode laser using double feedback from two external mirrors

    DEFF Research Database (Denmark)

    Chi, M.; Bøgh, A.-S.; Thestrup, B.

    2004-01-01

    In this letter, a symmetric double-feedback configuration, to improve the beam quality of broad-area diode lasers is demonstrated. With this configuration, a symmetric double-lobed far field can be obtained, and this configuration leads to good beam quality. The beam quality factor M-2 of a diode...

  15. Spectral Slope as an Indicator of Pasture Quality

    Directory of Open Access Journals (Sweden)

    Rachel Lugassi

    2014-12-01

    Full Text Available In this study, we develop a spectral method for assessment of pasture quality based only on the spectral information obtained with a small number of wavelengths. First, differences in spectral behavior were identified across the near infrared–shortwave infrared spectral range that were indicative of changes in chemical properties. Then, slopes across different spectral ranges were calculated and correlated with the changes in crude protein (CP, neutral detergent fiber (NDF and metabolic energy concentration (MEC. Finally, partial least squares (PLS regression analysis was applied to identify the optimal spectral ranges for accurate assessment of CP, NDF and MEC. Six spectral domains and a set of slope criteria for real-time evaluation of pasture quality were suggested. The evaluation of three level categories (low, medium, high for these three parameters showed a success rate of: 73%–96% for CP, 72%–87% for NDF and 60%–85% for MEC. Moreover, only one spectral range, 1748–1764 nm, was needed to provide a good estimation of CP, NDF and MEC. Importantly, five of the six selected spectral regions were not affected by water absorbance. With some modifications, this rationale can be applied to further analyses of pasture quality from airborne sensors.

  16. [Patient satisfaction as a quality indicator in mental health].

    Science.gov (United States)

    Fernández-Martín, L C; Iglesias-de-Sena, H; Fombellida-Velasco, C; Vicente-Torres, I; Alonso-Sardón, M; Mirón Canelo, J A

    2016-01-01

    To improve the quality of care in a Mental Health Hospital and identify the level of patient satisfaction. A descriptive, longitudinal, and retrospective study was conducted on 666 patients who completed treatment in the Mental Health Day Hospital of Salamanca, during the period 1994-2012, using the Hospital Management Annual Reports. A questionnaire designed for this purpose was used as the measurement tool. Most of the patients satisfactorily valued aspects, such as the general impression of the treatment (90% said «good/fairly good») and perception of being helped (94% perceived «very/fairly helped»); with 83% believing that the hospital is accessible. As regards empathy-understanding, it was noted that 14% feel discontent. While 18% of patients expected to be completely cured, the 83% of patients that finished their treatment have said that, in their opinion, the symptoms have subsided «very or somewhat». As regards the knowledge that they have about their disease, 30% believe it has advanced «a lot.» Based on the perceptions reported by patients, it may be said that in general, the level of user satisfaction in the Mental Health Day Hospital is high. Assessing quality through the user opinions helps control the quality, considering that patient satisfaction is a good indicator of result of the care received during their hospitalisation. Copyright © 2016 SECA. Publicado por Elsevier España, S.L.U. All rights reserved.

  17. [Comparative assessment of sanitary and epidemic importance of indicator coliform indices of drinking water quality].

    Science.gov (United States)

    Rakhmanin, Yu A; Ivanova, L V; Artemova, T Z; Gipp, E K; Zagaynova, A V; Maksimkina, T N; Krasnyak, A V; Zhuravlev, P V; Aleshnya, V V; Panasovets, O P

    2016-01-01

    The used methodology of the scientific substantiation of indicators is in the establishment of the conformity of laws of vital activity of indicator and pathogenic microorganisms in the real conditions of the action of the complex of factors, including disinfecting agents. In the one water sample simultaneously there were determined both the general indicator (GICB), thermotolerant (TTCB), glucose positive (GPCB) coliform bacteria, E.coli. On the base of long-term research in the various regions of the Russian Federation, as well with bearing in mind the analysis of domestic and foreign data, comparing the water quality and the incidence of intestinal infections in population it is recommended to use the index of determination of the total number glucose positive coliform bacteria (GPCB), which brings together a much broader range of bacteria of the Enterobacteriaceae family in comparison with total coliform bacteria (TCB) and thermotolerant coliform bacteria (TTCB) and warrants the absence in the test volume of water as an indicator lactose positive (E.coli, TCB, TTCB) and pathogens (salmonella) and potentially pathogenic bacteria which do not ferment lactose. Proposed index of GPCB is shown to allow to assess epidemiological risks not only more accurate, but also more efficiently without increasing the cost performance of bacteriological research.

  18. Quality Indicators for Evaluating Prehospital Emergency Care: A Scoping Review.

    Science.gov (United States)

    Howard, Ian; Cameron, Peter; Wallis, Lee; Castren, Maaret; Lindstrom, Veronica

    2018-02-01

    Introduction Historically, the quality and performance of prehospital emergency care (PEC) has been assessed largely based on surrogate, non-clinical endpoints such as response time intervals or other crude measures of care (eg, stakeholder satisfaction). However, advances in Emergency Medical Services (EMS) systems and services world-wide have seen their scope and reach continue to expand. This has dictated that novel measures of performance be implemented to compliment this growth. Significant progress has been made in this area, largely in the form of the development of evidence-informed quality indicators (QIs) of PEC. Problem Quality indicators represent an increasingly popular component of health care quality and performance measurement. However, little is known about the development of QIs in the PEC environment. The purpose of this study was to assess the development and characteristics of PEC-specific QIs in the literature. A scoping review was conducted through a search of PubMed (National Center for Biotechnology Information, National Institutes of Health; Bethesda, Maryland USA); EMBase (Elsevier; Amsterdam, Netherlands); CINAHL (EBSCO Information Services; Ipswich, Massachusetts USA); Web of Science (Thomson Reuters; New York, New York USA); and the Cochrane Library (The Cochrane Collaboration; Oxford, United Kingdom). To increase the sensitivity of the literature, a search of the grey literature and review of select websites was additionally conducted. Articles were selected that proposed at least one PEC QI and whose aim was to discuss, analyze, or promote quality measurement in the PEC environment. The majority of research (n=25 articles) was published within the last decade (68.0%) and largely originated within the USA (68.0%). Delphi and observational methodologies were the most commonly employed for QI development (28.0%). A total of 331 QIs were identified via the article review, with an additional 15 QIs identified via the website review. Of

  19. Strength and stiffness of small glued-laminated beams with different qualities of tension laminations

    Science.gov (United States)

    Catherine M. Marx; Russell C. Moody

    1981-01-01

    A total of 180 small Douglas Fir–Larch (DF-L) or Southern Pine (SP) glued-laminated beams were evaluated to determine the tension lamination quality necessary to obtain desired design stresses. The test beams had either the regular laminating grades of L1 DF-L/No. 1D SP or the special 302-24 laminating grade as tension laminations. Because an initial set of SP beams...

  20. Effects of electron beam irradiation on the microbial growth and quality of beef jerky during storage

    Science.gov (United States)

    Kim, Hyun-Jin; Chun, Ho-Hyun; Song, Hyeon-Jeong; Song, Kyung-Bin

    2010-11-01

    Electron beam irradiation was applied to improve the microbial safety of beef jerky during storage. Beef jerky samples were irradiated at doses of 1, 3, 5, and 10 kGy and stored at 20 °C for 60 d. Microbiological data indicated that the populations of total aerobic bacteria significantly decreased with increasing irradiation dosage. In particular, the populations of total aerobic bacteria were significantly decreased by 1.76 log CFU/g at 10 kJ/m 2, compared to the control. Color measurements showed reduced Hunter L and a values of beef jerky for all the treatments during storage, and the Hunter L, a, and b values of beef jerky were not significantly different among the treatments. Sensory evaluation results also showed that electron beam irradiation did not affect sensory scores in overall during storage. Therefore, the results suggest that electron beam irradiation could be useful in improving the microbial safety without impairing the quality of beef jerky during storage.

  1. Effects of electron beam irradiation on the microbial growth and quality of beef jerky during storage

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun-Jin; Chun, Ho-Hyun; Song, Hyeon-Jeong [Department of Food Science and Technology, Chungnam National University, Daejeon 305-764 (Korea, Republic of); Song, Kyung-Bin, E-mail: kbsong@cnu.ac.k [Department of Food Science and Technology, Chungnam National University, Daejeon 305-764 (Korea, Republic of)

    2010-11-15

    Electron beam irradiation was applied to improve the microbial safety of beef jerky during storage. Beef jerky samples were irradiated at doses of 1, 3, 5, and 10 kGy and stored at 20 {sup o}C for 60 d. Microbiological data indicated that the populations of total aerobic bacteria significantly decreased with increasing irradiation dosage. In particular, the populations of total aerobic bacteria were significantly decreased by 1.76 log CFU/g at 10 kJ/m{sup 2}, compared to the control. Color measurements showed reduced Hunter L and a values of beef jerky for all the treatments during storage, and the Hunter L, a, and b values of beef jerky were not significantly different among the treatments. Sensory evaluation results also showed that electron beam irradiation did not affect sensory scores in overall during storage. Therefore, the results suggest that electron beam irradiation could be useful in improving the microbial safety without impairing the quality of beef jerky during storage.

  2. Evaluating how variants of floristic quality assessment indicate wetland condition.

    Science.gov (United States)

    Kutcher, Thomas E; Forrester, Graham E

    2018-03-28

    Biological indicators are useful tools for the assessment of ecosystem condition. Multi-metric and multi-taxa indicators may respond to a broader range of disturbances than simpler indicators, but their complexity can make them difficult to interpret, which is critical to indicator utility for ecosystem management. Floristic Quality Assessment (FQA) is an example of a biological assessment approach that has been widely tested for indicating freshwater wetland condition, but less attention has been given to clarifying the factors controlling its response. FQA quantifies the aggregate of vascular plant species tolerance to habitat degradation (conservatism), and model variants have incorporated species richness, abundance, and indigenity (native or non-native). To assess bias, we tested FQA variants in open-canopy freshwater wetlands against three independent reference measures, using practical vegetation sampling methods. FQA variants incorporating species richness did not correlate with our reference measures and were influenced by wetland size and hydrogeomorphic class. In contrast, FQA variants lacking measures of species richness responded linearly to reference measures quantifying individual and aggregate stresses, suggesting a broad response to cumulative degradation. FQA variants incorporating non-native species, and a variant additionally incorporating relative species abundance, improved performance over using only native species. We relate our empirical findings to ecological theory to clarify the functional properties and implications of the FQA variants. Our analysis indicates that (1) aggregate conservatism reliably declines with increased disturbance; (2) species richness has varying relationships with disturbance and increases with site area, confounding FQA response; and (3) non-native species signal human disturbance. We propose that incorporating species abundance can improve FQA site-level relevance with little extra sampling effort. Using our

  3. Diode pumped 1kHz high power Nd:YAG laser with excellent beam quality

    NARCIS (Netherlands)

    Godfried, Herman; Godfried, H.P; Offerhaus, Herman L.

    1997-01-01

    The design and operation of a one kilohertz diode pumped all solid-state Nd:YAG master oscillator power amplifier system with a phase conjugate mirror is presented. The setup allows high power scaling without reduction in beam quality.

  4. A feasibility study of Dynamic Phantom scanner for quality assurance of photon beam profiles at various gantry angles.

    Science.gov (United States)

    Zhang, Yunkai; Hsi, Wen C; Chu, James C H; Bernard, Damian B; Abrams, Ross A

    2005-01-01

    ) were observed. Additional profiles with the gantry at 90 degrees and 270 degrees were performed for both MLC- and jaw-shaped photon beams and electron beams to evaluate the effect of gantry rotation. General good agreement is seen (less than 1 % variation) at all field sizes for collimator-shaped 6 MV and 18 MV photon beams. Similar variations observed for MLC-shaped photon beams indicate that the uncertainty in MLC position is similar to that for the collimator jaws. We conclude that the Dynamic Phantom scanner is a useful device for the routine quality assurance on beam profiles of photon beams and for constancy check on electron beams at various gantry angles. Caution should be taken when using this device to acquire basic electron dosimetry data.

  5. Longitudinal beam parameters and quality checks of the LHC beam in the SPS: further results and comparisons

    CERN Document Server

    Papotti, G; Linnecar, T; Shaposhnikova, E; Tückmantel, Joachim; CERN. Geneva. AB Department

    2008-01-01

    Controlled longitudinal emittance blow up is used, along with other measures, to stabilize the nominal LHC beam in the SPS. Two Machine Development studies (MDs) were carried out in 2007 to evaluate the effectiveness of different noise settings for the longitudinal blow up of the beam. The noise settings are affected by both the presence of the 800 MHz RF system and intensity effects which modify the synchrotron frequency distribution inside the bunch. The results for the first MD are reported in Note [1]. This Note reports on the results of the second MD, carried out on 2007-10-17, as well as the comparison between the two in order to analyse the differences between the two occasions. Figures of merit are used that allow rapid evaluation of the quality of the beam as for example stability and bunch length uniformity across batches.

  6. Design of RF chopper system for improving beam quality in FEL injector with thermionic gun

    International Nuclear Information System (INIS)

    Chen, Q.; Qin, B.; Tan, P.; Hu, T.; Pei, Y.; Zhang, F.

    2014-01-01

    For a linac-based Free Electron Laser (FEL), good beam quality largely contributes to the success of the final radiation. An imperfection confronted with the HUST THz-FEL facility is the long beam tail that emerges in the electron gun and exists through the whole beam line. This paper proposes to deploy a chopper system after the electron gun to truncate the beam tails before they enter into the linac. Physical dimensions of the chopper cavity are discussed in detail and we have developed and derived new analytical expressions applying to all frequencies for the optimal design. Also, technical issues of the cavity are considered. Beam dynamic simulation is performed to examine the truncation effect and the results show that more than 78% of the beam tail can be removed effectively, while preserving the emittance and energy spread in acceptable level

  7. Aggregate Indices Method in Soil Quality Evaluation Using the Relative Soil Quality Index

    Directory of Open Access Journals (Sweden)

    Ho Ngoc Pham

    2015-01-01

    Full Text Available This paper presents a new approach to assess the soil quality by aggregate indices using the Relative Soil Quality Index (RSQI proposed by Ho Ngoc Pham. RSQI is integrated from the individual indices into a simple formula for overall assessment of the soil quality. RSQI is different from other approaches. Particularly, the individual indices and the weighting factors of Pham are calculated from the analytical laboratory data and the environmental standards, respectively, and not self-regulated as in methods of some other authors. In this paper, the authors applied the RSQI to assess the Soil Environmental Quality of rice intensive cultivation areas through a case study in Haiduong province in 2013. The RSQI is calculated for sampling points in 12 districts and simulated the Soil Environmental Quality on GIS map. The results show that the Soil Environmental Quality of rice intensive cultivation areas in Haiduong is predominantly divided into three levels: good, moderate, and poor. According to the report of General Statistics Office for Haiduong province, rice intensive cultivation areas in 2013 achieved a relatively high average rice yield of 5.90 tonnes per hectare; it means actual soil properties are in line with results of the research.

  8. A feasibility study of the Dynamic Phantom scanner for quality assurance of beam profiles at various gantry angles

    Science.gov (United States)

    Zhang, Yunkai; Hsi, Wen C.; Chu, James C.H.; Bernard, Damian B.; Abrams, Ross A.

    2005-01-01

    ) were observed. Additional profiles with the gantry at 90° and 270° were performed for both MLC‐ and jaw‐shaped photon beams and electron beams to evaluate the effect of gantry rotation. General good agreement is seen (less than 1 % variation) at all field sizes for collimator‐shaped 6 MV and 18 MV photon beams. Similar variations observed for MLC‐shaped photon beams indicate that the uncertainty in MLC position is similar to that for the collimator jaws. We conclude that the Dynamic Phantom scanner is a useful device for the routine quality assurance on beam profiles of photon beams and for constancy check on electron beams at various gantry angles. Caution should be taken when using this device to acquire basic electron dosimetry data. PACS number: 87.53.‐j PMID:15940212

  9. Beam Quality Preservation in the CERN PS-SPS Complex

    CERN Multimedia

    Arduini, Gianluigi

    2004-01-01

    The LHC will require beams of unprecedented transverse and longitudinal brightness. Their production imposes tight constraints on the emittance growth in each element of the LHC injector chain, namely the PS-SPS Accelerator Complex. The problems encountered at the different stages of the acceleration in the complex span a wide range of topics, such as injection matching, RF gymnastics, space charge, transverse and longitudinal single- and coupled-bunch instabilities, and electron cloud effects. The measurement techniques developed and applied to identify and study the various sources of emittance dilution to the high precision required for the LHC beams and the solutions found to control such phenomena are illustrated.

  10. Quality indicators in rheumatoid arthritis: results from the METEOR database.

    Science.gov (United States)

    Navarro-Compán, Victoria; Smolen, Josef S; Huizinga, Tom W J; Landewé, Robert; Ferraccioli, Gianfranco; da Silva, José A P; Moots, Robert J; Kay, Jonathan; van der Heijde, Désirée

    2015-09-01

    To test the feasibility of collecting, storing, retrieving and analysing necessary information to fulfil a preliminary set of quality indicators (QIs) that have been proposed by an international task force in a large multinational clinical practice database of patients with RA. Data from all 12 487 patients with 46 005 visits in the Measurement of Efficacy of Treatment in the Era of Outcome in Rheumatology database from January 2008 until January 2012 were analysed to test the feasibility of collecting information on 10 QIs: time to diagnosis; frequency of visits; assessment of autoantibodies and radiographs, disease activity and function; disease remission, low disease activity, normal function; time to first DMARD and type of first DMARD. For each QI, two aspects were assessed: information availability and target achievement. Information was available for <50% of patients regarding the following QIs: time to diagnosis, assessment of ACPAs or radiographs, time to first DMARD and type of first DMARD. Information was available for function assessment in 49% of visits and 67% of patients and for disease activity assessment in 85% of visits and 86% of patients. Information relevant to the QI frequency of visits was available for all patients. Relevant information to calculate the proportion of patients who achieved a defined target could be obtained for all QIs. Collecting storing, retrieving and analysing the core data necessary to meaningfully assess quality of care is feasible in a multinational, practice-based electronic database. © The Author 2015. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  11. Production of high-quality electron bunches by dephasing and beam loading in channeled and unchanneled laser plasma accelerators

    International Nuclear Information System (INIS)

    Geddes, C.G.R.; Toth, Cs.; Tilborg, J. van; Esarey, E.; Schroeder, C.B.; Bruhwiler, D.; Nieter, C.; Cary, J.; Leemans, W.P.

    2005-01-01

    High-quality electron beams, with a few 10 9 electrons within a few percent of the same energy above 80 MeV, were produced in a laser wakefield accelerator by matching the acceleration length to the length over which electrons were accelerated and outran (dephased from) the wake. A plasma channel guided the drive laser over long distances, resulting in production of the high-energy, high-quality beams. Unchanneled experiments varying the length of the target plasma indicated that the high-quality bunches are produced near the dephasing length and demonstrated that channel guiding was more stable and efficient than relativistic self-guiding. Consistent with these data, particle-in-cell simulations indicate production of high-quality electron beams when trapping of an initial bunch of electrons suppresses further injection by loading the wake. The injected electron bunch is then compressed in energy by dephasing, when the front of the bunch begins to decelerate while the tail is still accelerated

  12. Quantitative image quality evaluation for kV cone-beam CT-based IGRT

    International Nuclear Information System (INIS)

    Lim, S Y; Zin, Hafiz M

    2017-01-01

    The objective of this study is to quantitatively evaluate the image quality of a kV cone-beam CT-based IGRT system (Elekta, XVI) using two commercial CT image quality phantoms, Catphan-600 and CIRS-062QA. Both phantoms consist of similar image quality test modules (uniformity, CT linearity and spatial resolution) but each phantom has different diameter and test pattern design. Each test module was imaged separately using an optimised cone-beam CT imaging parameter. The quality metrics of the reconstructed images were analysed using algorithms developed with MatLab. The image uniformity and the spatial resolution measured with Catphan were of 4% and 40% greater respectively, compared to those measured with CIRS phantom. The differences were due to the beam scattering and hardening originated from the CIRS phantom holder. The contrast-to-noise ratio (CNR) values measured with CIRS phantom were at least 2% higher than that of Catphan. The diameter of CIRS phantom is smaller and resulted in lower beam attenuation. The quantitative image quality assessment algorithms developed for both phantoms provided a phantom-specific set of reference values for a cone-beam CT imaging system as recommended by AAPM TG-142. Further investigation will be performed to resolve beam hardening issue arising from the CIRS phantom holder. (paper)

  13. Key Performance Indicators in the Evaluation of the Quality of Radiation Safety Programs.

    Science.gov (United States)

    Schultz, Cheryl Culver; Shaffer, Sheila; Fink-Bennett, Darlene; Winokur, Kay

    2016-08-01

    Beaumont is a multiple hospital health care system with a centralized radiation safety department. The health system operates under a broad scope Nuclear Regulatory Commission license but also maintains several other limited use NRC licenses in off-site facilities and clinics. The hospital-based program is expansive including diagnostic radiology and nuclear medicine (molecular imaging), interventional radiology, a comprehensive cardiovascular program, multiple forms of radiation therapy (low dose rate brachytherapy, high dose rate brachytherapy, external beam radiotherapy, and gamma knife), and the Research Institute (including basic bench top, human and animal). Each year, in the annual report, data is analyzed and then tracked and trended. While any summary report will, by nature, include items such as the number of pieces of equipment, inspections performed, staff monitored and educated and other similar parameters, not all include an objective review of the quality and effectiveness of the program. Through objective numerical data Beaumont adopted seven key performance indicators. The assertion made is that key performance indicators can be used to establish benchmarks for evaluation and comparison of the effectiveness and quality of radiation safety programs. Based on over a decade of data collection, and adoption of key performance indicators, this paper demonstrates one way to establish objective benchmarking for radiation safety programs in the health care environment.

  14. Tilting the jaw to improve the image quality or to reduce the dose in cone-beam computed tomography

    International Nuclear Information System (INIS)

    Luckow, Marlen; Deyhle, Hans; Beckmann, Felix; Dagassan-Berndt, Dorothea; Müller, Bert

    2011-01-01

    Objective: The image quality in cone-beam computed tomography (CBCT) should be improved tilting the mandible that contains two dental titanium implants, within the relevant range of motion. Materials and methods: Using the mandible of a five-month-old pig, CBCT was performed varying the accelerating voltage, beam current, the starting rotation angle of the mandible in the source-detector plane and the tilt angles of the jaw with respect to the source-detector plane. The different datasets were automatically registered with respect to micro CT data to extract the common volume and the deviance to the pre-defined standard that characterizes the image quality. Results: The variations of the accelerating voltage, beam current and the rotation within the source-detection plane provided the expected quantitative behavior indicating the appropriate choice of the imaging quality factor. The tilting of the porcine mandible by about 14° improves the image quality by almost a factor of two. Conclusions: The tilting of the mandible with two dental implants can be used to significantly reduce the artifacts of the strongly X-ray absorbing materials in the CBCT images. The comparison of 14° jaw tilting with respect to the currently recommended arrangement in plane with the teeth demonstrates that the applied exposure time and the related dose can be reduced by a factor of four without decreasing the image quality.

  15. Enzyme activities by indicator of quality in organic soil

    Science.gov (United States)

    Raigon Jiménez, Mo; Fita, Ana Delores; Rodriguez Burruezo, Adrián

    2016-04-01

    The analytical determination of biochemical parameters, as soil enzyme activities and those related to the microbial biomass is growing importance by biological indicator in soil science studies. The metabolic activity in soil is responsible of important processes such as mineralization and humification of organic matter. These biological reactions will affect other key processes involved with elements like carbon, nitrogen and phosphorus , and all transformations related in soil microbial biomass. The determination of biochemical parameters is useful in studies carried out on organic soil where microbial processes that are key to their conservation can be analyzed through parameters of the metabolic activity of these soils. The main objective of this work is to apply analytical methodologies of enzyme activities in soil collections of different physicochemical characteristics. There have been selective sampling of natural soils, organic farming soils, conventional farming soils and urban soils. The soils have been properly identified conserved at 4 ° C until analysis. The enzyme activities determinations have been: catalase, urease, cellulase, dehydrogenase and alkaline phosphatase, which bring together a representative group of biological transformations that occur in the soil environment. The results indicate that for natural and agronomic soil collections, the values of the enzymatic activities are within the ranges established for forestry and agricultural soils. Organic soils are generally higher level of enzymatic, regardless activity of the enzyme involved. Soil near an urban area, levels of activities have been significantly reduced. The vegetation cover applied to organic soils, results in greater enzymatic activity. So the quality of these soils, defined as the ability to maintain their biological productivity is increased with the use of cover crops, whether or spontaneous species. The practice of cover based on legumes could be used as an ideal choice

  16. Air Quality Indicators at Lake Merritt, Oakland, California

    Science.gov (United States)

    Bulatov, D.; Collins, B.; Hsiao, J.; Majors, A.; Liang, J.

    2007-12-01

    Lake Merritt is significant in its role as both a recreational center for humans, as well as a refuge for migratory wild birds. It is, however, closely surrounded by streets and highways, and even sees a large amount of water traffic by motor-driven boats and pontoons. These two factors contribute to what we suspect is a generally high level of emissions in the atmosphere surrounding the lake. While the harmful components of these emissions can be measured directly using specialized and generally expensive tools, the goal of our research is to explore the use of tree leaves as indicators of air quality. Properties of atmospheric air directly affect the quality of leaves because of plants' reliance on photosynthesis. In brief, photosynthesis requires the input of sunlight, water, and carbon dioxide to produce oxygen and glucose. The gateways through which many of these inputs and outputs pass are essential to every leaf's survival and are called stomata. However, water is an exception; since its entry into the plant's vascular system is through the roots, water generally diffuses outward at stomatal openings rather than inward. Therefore, plants must strike a balance between gaining carbon dioxide and losing water, as well as risk exposure to toxic compounds in the air itself. Primarily, guard cells fulfill this purpose by closing over stomatal openings to conserve water. However, we also believe that over generations of leaves, the absolute number of stomata itself can change to reflect the surrounding environment. That is, increases in carbon dioxide must coincide with higher levels of toxic compounds, which force the number of stomata to decrease over time. Our research examined the relationship between quantitative presence of stomata for several species of trees and the levels of carbon dioxide, oxygen, and wind-speed for ten sites around Lake Merritt. Wind-speed is one of our primary measures because increasing wind velocity leads to water diffusing out of the

  17. Constancy check of beam quality in conventional diagnostic X-ray equipment

    International Nuclear Information System (INIS)

    Costa, Alessandro M.; Badin, Romulo S.; Leite, Marina S.; Caldas, Linda V.E.

    2008-01-01

    A tandem ionization chamber was developed for quality control programs of X-ray equipment used in conventional radiography and mammography. A methodology for the use of the tandem chamber in the constancy check of diagnostic X-ray beam qualities was established. The application at a medical X-ray imaging facility of this established methodology is presented. The use of the tandem chamber in the constancy check of diagnostic X-ray beam qualities is a useful method to control the performance of the X-ray equipment

  18. Experimental and Monte Carlo-based determination of the beam quality specifier for TomoTherapyHD treatment units.

    Science.gov (United States)

    Howitz, S; Schwedas, M; Wiezorek, T; Zink, K

    2017-10-12

    was s w,a Δ =1.126±0.1%, which is in excellent agreement with the value directly calculated by Monte Carlo simulations. The agreement is a good indication that the equations proposed by Sauer and Palmans are able to calculate the beam quality specifier under reference conditions from measurements in arbitrary photon field sizes with high accuracy and are applicable for the TomoTherapyHD treatment unit. Copyright © 2017. Published by Elsevier GmbH.

  19. Assessment of quality indicators in Spanish higher military education

    OpenAIRE

    Olmos Gómez Maria del Carmen; de Luna Emilio Berrocal; Olmedo Moreno Eva M.; Eisman Leonor Buendía; López Jorge Expósito; Núñez Christian Sánchez; Ramírez Eva Aguaded; Moral Marciana Pegalajar; Ruiz Pelegrina Juan José

    2016-01-01

    The quality assessment is subject to multiple interpretations of its content and purpose, and also regarding to methods and techniques used to develop it. Although purposes of assessment are varied, usually pursuit three goals: Improvement, accountability and information. Currently, the concept of quality evaluation has been replaced by the management of educational quality, as Matthew [6] point “the new culture of evaluation is no longer oriented to penalty, ranking or selection of people, a...

  20. Assessment of quality indicators in spanish higher military education

    OpenAIRE

    Olmos Gómez Maria del Carmen; de Luna Emilio Berrocal; Olmedo Moreno Eva M.; Eisman Leonor Buendía; López Jorge Expósito; Núñez Christian Sánchez; Ramírez Eva Aguaded; Moral Marciana Pegalajar; Ruiz Pelegrina Juan José

    2016-01-01

    The quality assessment is subject to multiple interpretations of its content and purpose, and also regarding to methods and techniques used to develop it. Although purposes of assessment are varied, usually pursuit three goals: Improvement, accountability and information. Currently, the concept of quality evaluation has been replaced by the management of educational quality, as Matthew [6] point “the new culture of evaluation is no longer oriented to penalty, ranking or selection of people, a...

  1. Quality Indicators of Intravenous Thrombolysis from North India.

    Science.gov (United States)

    William, Akanksha Grace; Pannu, Aman; Kate, Mahesh Pundlik; Jaison, Vineeth; Gupta, Leenu; Bose, Smrithi; Sahonta, Rajeshwar; Sebastian, Ivy; Pandian, Jeyaraj Durai

    2017-01-01

    Data on intravenous (IV) thrombolysis using tissue plasminogen activator (tPA) are limited from low- and middle-income countries. We aimed to assess the quality indicators of IV thrombolysis in our stroke unit. All stroke patients admitted in our hospital from October 2008 to April 2017 were included in this study. Data were collected prospectively by trained research staff in a detailed case record form. Outcome was assessed using modified Rankin Scale (mRS, 0-1 good outcome). Of the total 4720 stroke patients seen, 944 (20%) came within window period (<4.5 h). Of these, 214 (4.5%) were eligible for thrombolysis and 170 (3.6%) were thrombolysed, relatives of 23 (23/214, 10.7%) patients denied consent, and 21 (9.8%) patients could not afford tPA. The mean age of thrombolysed patients was 58.4 (range 19-95) years. Median NIHSS at admission was 12 (interquartile range 2-24). Average onset-to-door (O-D) time was 76.8 (5-219) min, door-to-examination (D-E) time was 17.8 (5-105) min, door-to-CT (D-CT) time was 48 (1-205) min, and door-to-needle (D-N) time was 90 (20-285) min. At 6 months, 110 (64.7%) patients were contactable and 82 (74.5%) patients had good outcome (mRS 0-1). Thrombolysis rate has steadily increased at the center without undue adverse effects even in the elderly. D-E and D-CT times have reduced, but O-D and D-N times need further improvement. More patients could be thrombolysed if the cost of tPA is reduced and the consent process is waived.

  2. Effect of electron beam on quality and physiological metabolism of blueberry

    International Nuclear Information System (INIS)

    Zhou Huijuan; Ye Zhengwen; Zhang Xueying; Su Mingshen; Du Jihong; Zhang Minqian

    2013-01-01

    In order to explore safe, simple and effective storage technology, experiment was conducted with 'ai li ao te' blueberry for studying the effect of electron beam on quality and physiological metabolism. Fruit was stored at temperature of (1 ± 0.5)℃, with RH of 80% ∼ 85%, and treated with electron beam of 0.5, 1, 1.5, 2, 3 kGy. The results showed that the proper dose of electron beam could decline the bad fruit rate and weightlessness, restrain respiration intensity, alleviate the decline of soluble solids, acid and Vc content. Meanwhile it did not have significant negative effects on pulp colour. All these showed that electron beam of 1 kGy treatment could keep the best storage quality of blueberry, keep the sound berry and weightlessness rate at > 90% and < 10% respectively, prolong the effective storage time from 30d to 60d. (authors)

  3. Formation of a high quality electron beam using photo cathode RF electron gun

    International Nuclear Information System (INIS)

    Washio, Masakazu

    2000-01-01

    Formation of a high quality electron beam using photo cathode RF electron gun is expected for formation of a next generation high brilliant X-ray beam and a source for electron and positron collider. And, on a field of material science, as is possible to carry out an experiment under ultra short pulse and extremely high precision in time, it collects large expectation. Recently, formation of high quality beam possible to develop for multi directions and to use by everyone in future has been able to realize. Here were explained on electron beam source, principle and component on RF electron gun, working features on RF gun, features and simulation of RF gun under operation, and some views in near future. (G.K.)

  4. Compliance with quality prescribing indicators linked to financial incentives: what about not incentivized indicators?: an observational study.

    Science.gov (United States)

    Fernández Urrusuno, R; Pérez Pérez, P; Montero Balosa, M C; Márquez Calzada, C; Pascual de la Pisa, B

    2014-03-01

    The aims of this study were to investigate whether general practitioners (GPs) who complied with quality prescribing indicators included in the pay-for-performance programmes also complied with quality prescribing indicators which are not linked to incentives and to compare the prescribing behaviour between those GPs who showed compliance with quality prescribing indicators linked to financial incentives and those who did not. This was a descriptive cross-sectional study which was conducted in 2007 in the Aljarafe Primary Care Area (Andalusia, Spain) and involved 37 Health Care Centres and 176 GPs. The main outcome was the results of a comparison of six quality prescribing indicators linked to incentives and 14 quality prescribing indicators not linked to incentives. The chi-square test was used to compare qualitative variables. Quantitative variables were tested using Student's t test upon confirmation of normality. Those GPs showing compliance with the indicators included in the pay-for performance programme showed low levels of compliance with quality prescribing indicators that were unincentivised. With respect to compliance with the indicators not linked to financial incentives, we found no statistical difference between GPs who showed compliance with incentivised indicators (n = 57) and those showing non-compliance (n = 112) in terms of drug selection, with the exception of the selection of second- and third-line antibiotics and antihistamines, nor in terms of the appropriate use of drugs linked to patient's clinical conditions. The compliance of GPs showing compliance with quality prescribing indicators included in pay-for-performance programmes was not better than that of those who showed no compliance with other relevant quality prescribing indicators not linked to financial incentives.

  5. Quality indicators for international benchmarking of mental health care

    DEFF Research Database (Denmark)

    Hermann, Richard C; Mattke, Soeren; Somekh, David

    2006-01-01

    To identify quality measures for international benchmarking of mental health care that assess important processes and outcomes of care, are scientifically sound, and are feasible to construct from preexisting data.......To identify quality measures for international benchmarking of mental health care that assess important processes and outcomes of care, are scientifically sound, and are feasible to construct from preexisting data....

  6. Price as an indicator for quality in international trade?

    DEFF Research Database (Denmark)

    Hansen, Jørgen Drud; Nielsen, Jørgen Ulff-Møller

    2011-01-01

    This paper examines the relation between price differences and quality differences in an oligopoly model with intra-industry trade, where goods are horizontally as well as vertically differentiated. The analysis demonstrates that the ratio of prices is not linked to the ratio of qualities in any ...

  7. Water Quality Indicators Guide [and Teacher's Handbook]: Surface Waters.

    Science.gov (United States)

    Terrell, Charles R.; Perfetti, Patricia Bytnar

    This guide aids in finding water quality solutions to problems from sediment, animal wastes, nutrients, pesticides, and salts. The guide allows users to learn the fundamental concepts of water quality assessment by extracting basic tenets from geology, hydrology, biology, ecology, and wastewater treatment. An introduction and eight chapters are…

  8. SU-E-T-464: On the Equivalence of the Quality Correction Factor for Pencil Beam Scanning Proton Therapy

    International Nuclear Information System (INIS)

    Sorriaux, J; Paganetti, H; Testa, M; Giantsoudi, D; Schuemann, J; Bertrand, D; Orban de Xivry, J.; Lee, J; Palmans, H; Vynckier, S; Sterpin, E

    2014-01-01

    Purpose: In current practice, most proton therapy centers apply IAEA TRS-398 reference dosimetry protocol. Quality correction factors (kQ) take into account in the dose determination process the differences in beam qualities used for calibration unit and for treatment unit. These quality correction factors are valid for specific reference conditions. TRS-398 reference conditions should be achievable in both scattered proton beams (i.e. DS) and scanned proton beams (i.e. PBS). However, it is not a priori clear if TRS-398 kQ data, which are based on Monte Carlo (MC) calculations in scattered beams, can be used for scanned beams. Using TOPAS-Geant4 MC simulations, the study aims to determine whether broad beam quality correction factors calculated in TRS-398 can be directly applied to PBS delivery modality. Methods: As reference conditions, we consider a 10×10×10 cm 3 homogeneous dose distribution delivered by PBS system in a water phantom (32/10 cm range/modulation) and an air cavity placed at the center of the spread-out-Bragg-peak. In order to isolate beam differences, a hypothetical broad beam is simulated. This hypothetical beam reproduces exactly the same range modulation, and uses the same energy layers than the PBS field. Ion chamber responses are computed for the PBS and hypothetical beams and then compared. Results: For an air cavity of 2×2×0.2 cm 3 , the ratio of ion chamber responses for the PBS and hypothetical beam qualities is 0.9991 ± 0.0016. Conclusion: Quality correction factors are insensitive to the delivery pattern of the beam (broad beam or PBS), as long as similar dose distributions are achieved. This investigation, for an air cavity, suggests that broad beam quality correction factors published in TRS-398 can be applied for scanned beams. J. Sorriaux is financially supported by a public-private partnership involving the company Ion Beam Applications (IBA)

  9. Radiochromic film calibration for the RQT9 quality beam

    Science.gov (United States)

    Costa, K. C.; Gomez, A. M. L.; Alonso, T. C.; Mourao, A. P.

    2017-11-01

    When ionizing radiation interacts with matter it generates energy deposition. Radiation dosimetry is important for medical applications of ionizing radiation due to the increasing demand for diagnostic radiology and radiotherapy. Different dosimetry methods are used and each one has its advantages and disadvantages. The film is a dose measurement method that records the energy deposition by the darkening of its emulsion. Radiochromic films have a little visible light sensitivity and respond better to ionizing radiation exposure. The aim of this study is to obtain the resulting calibration curve by the irradiation of radiochromic film strips, making it possible to relate the darkening of the film with the absorbed dose, in order to measure doses in experiments with X-ray beam of 120 kV, in computed tomography (CT). Film strips of GAFCHROMIC XR-QA2 were exposed according to RQT9 reference radiation, which defines an X-ray beam generated from a voltage of 120 kV. Strips were irradiated in "Laboratório de Calibração de Dosímetros do Centro de Desenvolvimento da Tecnologia Nuclear" (LCD / CDTN) at a dose range of 5-30 mGy, corresponding to the range values commonly used in CT scans. Digital images of the irradiated films were analyzed by using the ImageJ software. The darkening responses on film strips according to the doses were observed and they allowed obtaining the corresponding numeric values to the darkening for each specific dose value. From the numerical values of darkening, a calibration curve was obtained, which correlates the darkening of the film strip with dose values in mGy. The calibration curve equation is a simplified method for obtaining absorbed dose values using digital images of radiochromic films irradiated. With the calibration curve, radiochromic films may be applied on dosimetry in experiments on CT scans using X-ray beam of 120 kV, in order to improve CT acquisition image processes.

  10. Determination of the quality index (Q) for photon beams at arbitrary field sizes.

    Science.gov (United States)

    Sauer, Otto A

    2009-09-01

    A commonly used beam quality index (Q) for high-energy photon beams is the tissue phantom ratio (TPR20,10) for a square field of 10 x 10 cm2 and SDD of 100 cm. On some specialized radiotherapy treatment equipment such a reference collimator setting is not achievable. Likewise a flat beam profile, not explicitly required in dosimetry protocols, but certainly influences the measurement of Q, is not always produced. In this work, a method was developed in order to determine Q at any field size, especially for small and nonflattened beams. An analytical relationship was derived between TPR20,10 for arbitrary field sizes and Q [the TPR20,10 (10 x 10 cm2)] as quality index. The proposed model equation was fitted to the measured and published data in order to achieve three general fit parameters. The procedure was then tested with published data from TomoTherapy and CyperKnife treatment devices. For standard flattened photon fields, the uncertainty in Q measured at any field size using the parameters derived from this study is better than 1%. In flattening-filter free beams, the proposed procedure results in a reliable Q for any field size setting. A method is introduced and successfully tested in order to measure the beam quality under nonstandard conditions. It can be used, e.g., to get energy dependent correction factors as tabulated in dosimetry codes of practice even if standard conditions are not adjustable.

  11. Headache service quality: evaluation of quality indicators in 14 specialist-care centres.

    Science.gov (United States)

    Schramm, Sara; Uluduz, Derya; Gouveia, Raquel Gil; Jensen, Rigmor; Siva, Aksel; Uygunoglu, Ugur; Gvantsa, Giorgadze; Mania, Maka; Braschinsky, Mark; Filatova, Elena; Latysheva, Nina; Osipova, Vera; Skorobogatykh, Kirill; Azimova, Julia; Straube, Andreas; Eren, Ozan Emre; Martelletti, Paolo; De Angelis, Valerio; Negro, Andrea; Linde, Mattias; Hagen, Knut; Radojicic, Aleksandra; Zidverc-Trajkovic, Jasna; Podgorac, Ana; Paemeleire, Koen; De Pue, Annelien; Lampl, Christian; Steiner, Timothy J; Katsarava, Zaza

    2016-12-01

    The study was a collaboration between Lifting The Burden (LTB) and the European Headache Federation (EHF). Its aim was to evaluate the implementation of quality indicators for headache care Europe-wide in specialist headache centres (level-3 according to the EHF/LTB standard). Employing previously-developed instruments in 14 such centres, we made enquiries, in each, of health-care providers (doctors, nurses, psychologists, physiotherapists) and 50 patients, and analysed the medical records of 50 other patients. Enquiries were in 9 domains: diagnostic accuracy, individualized management, referral pathways, patient's education and reassurance, convenience and comfort, patient's satisfaction, equity and efficiency of the headache care, outcome assessment and safety. Our study showed that highly experienced headache centres treated their patients in general very well. The centres were content with their work and their patients were content with their treatment. Including disability and quality-of-life evaluations in clinical assessments, and protocols regarding safety, proved problematic: better standards for these are needed. Some centres had problems with follow-up: many specialised centres operated in one-touch systems, without possibility of controlling long-term management or the success of treatments dependent on this. This first Europe-wide quality study showed that the quality indicators were workable in specialist care. They demonstrated common trends, producing evidence of what is majority practice. They also uncovered deficits that might be remedied in order to improve quality. They offer the means of setting benchmarks against which service quality may be judged. The next step is to take the evaluation process into non-specialist care (EHF/LTB levels 1 and 2).

  12. Metrology and quality of radiation therapy dosimetry of electron, photon and epithermal neutron beams

    Energy Technology Data Exchange (ETDEWEB)

    Kosunen, A

    1999-08-01

    In radiation therapy using electron and photon beams the dosimetry chain consists of several sequential phases starting by the realisation of the dose quantity in the Primary Standard Dosimetry Laboratory and ending to the calculation of the dose to a patient. A similar procedure can be described for the dosimetry of epithermal neutron beams in boron neutron capture therapy (BNCT). To achieve the required accuracy of the dose delivered to a patient the quality of all steps in the dosimetry procedure has to be considered. This work is focused on two items in the dosimetry chains: the determination of the dose in the reference conditions and the evaluation of the accuracy of dose calculation methods. The issues investigated and discussed in detail are: a)the calibration methods of plane parallel ionisation chambers used in electron beam dosimetry, (b) the specification of the critical dosimetric parameter i.e. the ratio of stopping powers for water to air, (S I ?){sup water} {sub air}, in photon beams, (c) the feasibility of the twin ionization chamber technique for dosimetry in epithermal neutron beams applied to BNCT and (d) the determination accuracy of the calculated dose distributions in phantoms in electron, photon, and epithermal neutron beams. The results demonstrate that up to a 3% improvement in the consistency of dose determinations in electron beams is achieved by the calibration of plane parallel ionisation chambers in high energy electron beams instead of calibrations in {sup 60}Co gamma beams. In photon beam dosimetry (S I ?){sup water} {sub air} can be determined with an accuracy of 0.2% using the percentage dose at the 10 cm depth, %dd(10), as a beam specifier. The use of %odd(10) requires the elimination of the electron contamination in the photon beam. By a twin ionisation chamber technique the gamma dose can be determined with uncertainty of 6% (1 standard deviation) and the total neutron dose with an uncertainty of 15 to 20% (1 standard deviation

  13. Metrology and quality of radiation therapy dosimetry of electron, photon and epithermal neutron beams

    International Nuclear Information System (INIS)

    Kosunen, A.

    1999-08-01

    In radiation therapy using electron and photon beams the dosimetry chain consists of several sequential phases starting by the realisation of the dose quantity in the Primary Standard Dosimetry Laboratory and ending to the calculation of the dose to a patient. A similar procedure can be described for the dosimetry of epithermal neutron beams in boron neutron capture therapy (BNCT). To achieve the required accuracy of the dose delivered to a patient the quality of all steps in the dosimetry procedure has to be considered. This work is focused on two items in the dosimetry chains: the determination of the dose in the reference conditions and the evaluation of the accuracy of dose calculation methods. The issues investigated and discussed in detail are: a)the calibration methods of plane parallel ionisation chambers used in electron beam dosimetry, (b) the specification of the critical dosimetric parameter i.e. the ratio of stopping powers for water to air, (S I ?) water air , in photon beams, (c) the feasibility of the twin ionization chamber technique for dosimetry in epithermal neutron beams applied to BNCT and (d) the determination accuracy of the calculated dose distributions in phantoms in electron, photon, and epithermal neutron beams. The results demonstrate that up to a 3% improvement in the consistency of dose determinations in electron beams is achieved by the calibration of plane parallel ionisation chambers in high energy electron beams instead of calibrations in 60 Co gamma beams. In photon beam dosimetry (S I ?) water air can be determined with an accuracy of 0.2% using the percentage dose at the 10 cm depth, %dd(10), as a beam specifier. The use of %odd(10) requires the elimination of the electron contamination in the photon beam. By a twin ionisation chamber technique the gamma dose can be determined with uncertainty of 6% (1 standard deviation) and the total neutron dose with an uncertainty of 15 to 20% (1 standard deviation). To improve the accuracy

  14. Theoretical and numerical studies on the transport of transverse beam quality in plasma-based accelerators

    International Nuclear Information System (INIS)

    Mehrling, Timon Johannes

    2014-11-01

    This work examines effects, which impact the transverse quality of electron-beams in plasma-based accelerators, by means of theoretical and numerical methods. Plasma-based acceleration is a promising candidate for future particle accelerator technologies. In plasma-based acceleration, highly intense laser beams or high-current relativistic particle beams are focused into a plasma to excite plasma-waves with extreme transverse and longitudinal electric fields. The amplitude of these fields exceed with 10-100 GV/m the ones in today's radio-frequency accelerators by several orders of magnitude, hence, in principle allowing for accordingly shorter and cheaper accelerators based on plasma. Despite the tremendous progress in the recent decade, beams from plasma accelerators are not yet achieving the quality as demanded for pivotal applications of relativistic electron-beams, e.g. free-electron lasers (FELs).Studies within this work examine how the quality can be optimized in the production of the beams and preserved during the acceleration and transport to the interaction region. Such studies cannot be approached purely analytical but necessitate numerical methods, such as the Particle-In-Cell (PIC) method, which can model kinetic, electrodynamic and relativistic plasma phenomena. However, this method is computationally too expensive for parameter-scans in three-dimensional geometries. Hence, a quasi-static PIC code was developed in connection with this work, which is significantly more effective than the full PIC method for a class of problems in plasma-based acceleration.The evolution of the emittance of beams which are injected into plasma modules was studied in this work by means of theoretical and the above numerical methods. It was shown that the beam parameters need to be matched accurately into the focusing plasma-channel in order to allow for beam-quality preservation. This suggested that new extraction and injection-techniques are required in staged plasma

  15. Direct measurement of electron beam quality conversion factors using water calorimetry.

    Science.gov (United States)

    Renaud, James; Sarfehnia, Arman; Marchant, Kristin; McEwen, Malcolm; Ross, Carl; Seuntjens, Jan

    2015-11-01

    In this work, the authors describe an electron sealed water calorimeter (ESWcal) designed to directly measure absorbed dose to water in clinical electron beams and its use to derive electron beam quality conversion factors for two ionization chamber types. A functioning calorimeter prototype was constructed in-house and used to obtain reproducible measurements in clinical accelerator-based 6, 9, 12, 16, and 20 MeV electron beams. Corrections for the radiation field perturbation due to the presence of the glass calorimeter vessel were calculated using Monte Carlo (MC) simulations. The conductive heat transfer due to dose gradients and nonwater materials was also accounted for using a commercial finite element method software package. The relative combined standard uncertainty on the ESWcal dose was estimated to be 0.50% for the 9-20 MeV beams and 1.00% for the 6 MeV beam, demonstrating that the development of a water calorimeter-based standard for electron beams over such a wide range of clinically relevant energies is feasible. The largest contributor to the uncertainty was the positioning (Type A, 0.10%-0.40%) and its influence on the perturbation correction (Type B, 0.10%-0.60%). As a preliminary validation, measurements performed with the ESWcal in a 6 MV photon beam were directly compared to results derived from the National Research Council of Canada (NRC) photon beam standard water calorimeter. These two independent devices were shown to agree well within the 0.43% combined relative uncertainty of the ESWcal for this beam type and quality. Absorbed dose electron beam quality conversion factors were measured using the ESWcal for the Exradin A12 and PTW Roos ionization chambers. The photon-electron conversion factor, kecal, for the A12 was also experimentally determined. Nonstatistically significant differences of up to 0.7% were found when compared to the calculation-based factors listed in the AAPM's TG-51 protocol. General agreement between the relative

  16. Rheumatologists' perception of systemic lupus erythematosus quality indicators: significant interest and perceived barriers.

    Science.gov (United States)

    Casey, Carolyn; Chung, Cecilia P; Crofford, Leslie J; Barnado, April

    2017-01-01

    Differences in quality of care may contribute to health disparities in systemic lupus erythematosus (SLE). Studies show low physician adherence rates to the SLE quality indicators but do not assess physician perception of SLE quality indicators or quality improvement. Using a cross-sectional survey of rheumatologists in the southeastern USA, we assessed the perception and involvement of rheumatologists in quality improvement and the SLE quality indicators. Using electronic mail, an online survey of 32 questions was delivered to 568 rheumatologists. With a response rate of 19% (n = 106), the majority of participants were male, Caucasian, with over 20 years of experience, and seeing adult patients in an academic setting. Participants had a positive perception toward quality improvement (81%) with a majority responding that the SLE quality indicators would significantly impact quality of care (54%). While 66% of respondents were familiar with the SLE quality indicators, only 18% of respondents reported using them in everyday practice. The most commonly reported barrier to involvement in quality improvement and the SLE quality indicators was time. Rheumatologists had a positive perception of the SLE quality indicators and agreed that use of the quality indicators could improve quality of care in SLE; however, they identified time as a barrier to implementation. Future studies should investigate methods to increase use of the SLE quality indicators.

  17. Machine Protection and Beam Quality during the LHC Injection Process

    CERN Document Server

    Verena Kain, V K

    2005-01-01

    This thesis is concerned with the machine protection system for the LHC injection process, where the intensity of the injected beam is alreay more than one order of magnitude above the equipment damage level. It focuses on a detailed specification, description and performance validation of the protection systems for the transfer from the SPS and the injection into the LHC. Numerical simulations were used to design active (equipment monitoring to ensure correct settings) and passive (collimators and absorbers) protection systems, and to analyze their performance. The simulation methodology was based on two common computer codes: energy deposition simulations were done with FLUKA and particle tracking was done with the tracking module of MAD-X. Realistic machine states were set up for the failure simulations including geometrical and optical mismatch, orbit tolerances, mechanical tolerances, power converter ripples, misalignment of elements and trajectory correction. The equipment damage limit was derived and c...

  18. Perceptions of quality teaching and learning as indicators for staff ...

    African Journals Online (AJOL)

    In many ways, the Vaal Triangle Technikon is a typical South African institution. Global and local changes have impacted the institution and it has been transformed dramatically during the past decade. Amidst these changes, providing quality teaching and learning remained the key performance area for academic members ...

  19. Performance Indicators For Quality In Surgical And Laboratory ...

    African Journals Online (AJOL)

    Methodology: Hospital records were reviewed and information recorded for planned and postponed operations, laboratory equipment, reagents, laboratory tests and quality assurance programmes. Results: In the year 2001 a total of 4332 non-emergency operations were planned, 3313 operations were performed and 1019 ...

  20. Biochemical quality indices of sorghum genotypes from east Africa ...

    African Journals Online (AJOL)

    Ezedom Theresa

    2014-01-08

    Jan 8, 2014 ... for the yeasts during fermentation process leading to production of alcohol as the end product. The quantity of protein in sorghum has a significant effect on brewing. (FAO, 1995; Beta et al., 1995). There is need for a ba- lance between proteins and other biochemical parame- ters in sorghum grain for quality ...

  1. Evaluation Criteria and Indicators of Quality for Internet Resources.

    Science.gov (United States)

    Wilkinson, Gene L.; And Others

    1997-01-01

    Most Web site rating systems overemphasize technological "bells and whistles." The University of Georgia's information quality criteria address site access and usability; resource identification and documentation; author identification; authority of author; information structure and design; relevance and scope, validity, and accuracy and…

  2. Use of benthic macroinvertebrates as indicators of water quality in ...

    African Journals Online (AJOL)

    Unsustainable anthropogenic activities, including intensive agriculture and grazing along River Njoro has resulted in the deterioration of river water quality. This is mainly through runoff and increased effluent discharge to the river. The river is the most important source of freshwater for the riparian communities and Lake ...

  3. The Discussion of Subjective Quality of Working Life Indicators

    Czech Academy of Sciences Publication Activity Database

    Vinopal, Jiří

    2012-01-01

    Roč. 44, č. 3 (2012), s. 385-401 ISSN 0049-1225 Institutional support: RVO:68378025 Keywords : Job Satisfaction * Quality of Working Life * Work Satisfaction Subject RIV: AO - Sociology, Demography Impact factor: 0.240, year: 2012 http://www.sav.sk/journals/uploads/06251222Vinopal%203-2012.pdf

  4. Quality Improvement in Critical Care: Selection and Development of Quality Indicators

    Science.gov (United States)

    Martin, Claudio M.; Project, The Quality Improvement in Critical Care

    2016-01-01

    Background. Caring for critically ill patients is complex and resource intensive. An approach to monitor and compare the function of different intensive care units (ICUs) is needed to optimize outcomes for patients and the health system as a whole. Objective. To develop and implement quality indicators for comparing ICU characteristics and performance within and between ICUs and regions over time. Methods. Canadian jurisdictions with established ICU clinical databases were invited to participate in an iterative series of face-to-face meetings, teleconferences, and web conferences. Eighteen adult intensive care units across 14 hospitals and 5 provinces participated in the process. Results. Six domains of ICU function were identified: safe, timely, efficient, effective, patient/family satisfaction, and staff work life. Detailed operational definitions were developed for 22 quality indicators. The feasibility was demonstrated with the collection of 3.5 years of data. Statistical process control charts and graphs of composite measures were used for data display and comparisons. Medical and nursing leaders as well as administrators found the system to be an improvement over prior methods. Conclusions. Our process resulted in the selection and development of 22 indicators representing 6 domains of ICU function. We have demonstrated the feasibility of such a reporting system. This type of reporting system will demonstrate variation between units and jurisdictions to help identify and prioritize improvement efforts. PMID:27493476

  5. Novel imaging and quality assurance techniques for ion beam therapy a Monte Carlo study

    CERN Document Server

    Rinaldi, I; Jäkel, O; Mairani, A; Parodi, K

    2010-01-01

    Ion beams exhibit a finite and well defined range in matter together with an “inverted” depth-dose profile, the so-called Bragg peak. These favourable physical properties may enable superior tumour-dose conformality for high precision radiation therapy. On the other hand, they introduce the issue of sensitivity to range uncertainties in ion beam therapy. Although these uncertainties are typically taken into account when planning the treatment, correct delivery of the intended ion beam range has to be assured to prevent undesired underdosage of the tumour or overdosage of critical structures outside the target volume. Therefore, it is necessary to define dedicated Quality Assurance procedures to enable in-vivo range verification before or during therapeutic irradiation. For these purposes, Monte Carlo transport codes are very useful tools to support the development of novel imaging modalities for ion beam therapy. In the present work, we present calculations performed with the FLUKA Monte Carlo code and pr...

  6. Active and intelligent packaging: The indication of quality and safety.

    Science.gov (United States)

    Janjarasskul, Theeranun; Suppakul, Panuwat

    2018-03-24

    The food industry has been under growing pressure to feed an exponentially increasing world population and challenged to meet rigorous food safety law and regulation. The plethora of media consumption has provoked consumer demand for safe, sustainable, organic, and wholesome products with "clean" labels. The application of active and intelligent packaging has been commercially adopted by food and pharmaceutical industries as a solution for the future for extending shelf life and simplifying production processes; facilitating complex distribution logistics; reducing, if not eliminating the need for preservatives in food formulations; enabling restricted food packaging applications; providing convenience, improving quality, variety and marketing features; as well as providing essential information to ensure consumer safety. This chapter reviews innovations of active and intelligent packaging which advance packaging technology through both scavenging and releasing systems for shelf life extension, and through diagnostic and identification systems for communicating quality, tracking and brand protection.

  7. Gluten-Free Diet Indications, Safety, Quality, Labels, and Challenges

    OpenAIRE

    Rostami, Kamran; Bold, Justine; Parr, Alison; Johnson, Matt W.

    2017-01-01

    A gluten-free diet (GFD) is the safest treatment modality in patient with coeliac disease (CD) and other gluten-related disorders. Contamination and diet compliance are important factors behind persistent symptoms in patients with gluten related-disorders, in particular CD. How much gluten can be tolerated, how safe are the current gluten-free (GF) products, what are the benefits and side effects of GFD? Recent studies published in Nutrients on gluten-free products? quality, availability, saf...

  8. Use of Quality Models and Indicators for Evaluating Test Quality in an ESP Course

    Directory of Open Access Journals (Sweden)

    IEVA RUDZINSKA

    2013-12-01

    Full Text Available Qualitative methods of assessment play a decisive role in education in general and in language learning in particular. The necessity to perform a qualitative assessment comes from both increased student competition in higher education institutions (HEIs, and hence higher demands for fair assessment, and a growing public awareness on higher education issues, and therefore the need to account for a wider circle of stakeholders, including society as a whole. The aim of the present paper is to study the regulations and laws pertaining to the issue of assessment in Latvian HEIs, as well as to carry out literature sources analysis about assessment in language testing, seeking to select criteria characterizing the quality of English for Specific Purposes (ESP tests and to apply the model of evaluating the quality of a language test on an example of a test in sport English, developed in a Latvian higher education institution. An analysis of the regulations and laws about assessment in higher education and literature sources about tests in language courses has enabled the development of a test quality model, consisting of seven intrinsic quality criteria: clarity, adequacy, deep approach, attractiveness, originality/similarity, orientation towards student learning result/process, test scoring objectivity/subjectivity. Quality criteria comprise eleven indicators. The reliability of the given model is evaluated by means of the whole model, its criteria and indicator Cronbach’s alphas and point-biserial (item-total correlations or discrimination indexes DI. The test was taken by 63 participants, all of them 2nd year full time students attending a Latvian higher education institution. A statistical data analysis was performed with SPSS 17.0. The results show that, although test adequacy and clarity is sufficiently high, attractiveness and deep approach should be improved. Also the reliability of one version of the test is higher than that of the other one

  9. Groundwater quality assessment using the water quality pollution indices in Toyserkan Plain

    OpenAIRE

    Soheil Sobhanardakani; Lobat Taghavi; Behzad Shahmoradi; Amin Jahangard

    2017-01-01

    Background: Iran is located within the dry and semi dry regions, thus almost 90% of the required water is secured via the use of groundwater. Owing to the increasing pollution of water resources, this study was performed to evaluate water quality pollution indices for heavy metals (As, Zn, Pb and Cu) contamination monitoring in Toyserkan Plain during spring and summer in 2012. Methods: A total of 20 ground water wells were chosen randomly. The samples were filtered (0.45 μm) and ...

  10. Practical use of a plastic scintillator for quality assurance of electron beam therapy

    Science.gov (United States)

    Yogo, Katsunori; Tatsuno, Yuya; Tsuneda, Masato; Aono, Yuki; Mochizuki, Daiki; Fujisawa, Yoshiki; Matsushita, Akihiro; Ishigami, Minoru; Ishiyama, Hiromichi; Hayakawa, Kazushige

    2017-06-01

    Quality assurance (QA) of clinical electron beams is essential for performing accurate and safe radiation therapy. However, with advances in radiation therapy, QA has become increasingly labor-intensive and time-consuming. In this paper, we propose a tissue-equivalent plastic scintillator for quick and easy QA of clinical electron beams. The proposed tool comprises a plastic scintillator plate and a charge-coupled device camera that enable the scintillation light by electron beams to be recorded with high sensitivity and high spatial resolution. Further, the Cerenkov image is directly subtracted from the scintillation image to discriminate Cerenkov emissions and accurately measure the dose profiles of electron beams with high spatial resolution. Compared with conventional methods, discrepancies in the depth profile improved from 7% to 2% in the buildup region via subtractive corrections. Further, the output brightness showed good linearity with dose, good reproducibility (deviations below 1%), and dose rate independence (within 0.5%). The depth of 50% dose measured with the tool, an index of electron beam quality, was within  ±0.5 mm of that obtained with an ionization chamber. Lateral brightness profiles agreed with the lateral dose profiles to within 4% and no significant improvement was obtained using Cerenkov corrections. Field size agreed to within 0.5 mm with those obtained with ionization chamber. For clinical QA of electron boost treatment, a disk scintillator that mimics the shape of a patient’s breast is applied. The brightness distribution and dose, calculated using a treatment planning system, was generally acceptable for clinical use, except in limited zones. Overall, the proposed plastic scintillator plate tool efficiently performs QA for electron beam therapy and enables simultaneous verification of output constancy, beam quality, depth, and lateral dose profiles during monthly QAs at lower doses of irradiation (small monitor units, MUs).

  11. Practical use of a plastic scintillator for quality assurance of electron beam therapy.

    Science.gov (United States)

    Yogo, Katsunori; Tatsuno, Yuya; Tsuneda, Masato; Aono, Yuki; Mochizuki, Daiki; Fujisawa, Yoshiki; Matsushita, Akihiro; Ishigami, Minoru; Ishiyama, Hiromichi; Hayakawa, Kazushige

    2017-06-07

    Quality assurance (QA) of clinical electron beams is essential for performing accurate and safe radiation therapy. However, with advances in radiation therapy, QA has become increasingly labor-intensive and time-consuming. In this paper, we propose a tissue-equivalent plastic scintillator for quick and easy QA of clinical electron beams. The proposed tool comprises a plastic scintillator plate and a charge-coupled device camera that enable the scintillation light by electron beams to be recorded with high sensitivity and high spatial resolution. Further, the Cerenkov image is directly subtracted from the scintillation image to discriminate Cerenkov emissions and accurately measure the dose profiles of electron beams with high spatial resolution. Compared with conventional methods, discrepancies in the depth profile improved from 7% to 2% in the buildup region via subtractive corrections. Further, the output brightness showed good linearity with dose, good reproducibility (deviations below 1%), and dose rate independence (within 0.5%). The depth of 50% dose measured with the tool, an index of electron beam quality, was within  ±0.5 mm of that obtained with an ionization chamber. Lateral brightness profiles agreed with the lateral dose profiles to within 4% and no significant improvement was obtained using Cerenkov corrections. Field size agreed to within 0.5 mm with those obtained with ionization chamber. For clinical QA of electron boost treatment, a disk scintillator that mimics the shape of a patient's breast is applied. The brightness distribution and dose, calculated using a treatment planning system, was generally acceptable for clinical use, except in limited zones. Overall, the proposed plastic scintillator plate tool efficiently performs QA for electron beam therapy and enables simultaneous verification of output constancy, beam quality, depth, and lateral dose profiles during monthly QAs at lower doses of irradiation (small monitor units, MUs).

  12. Quality assurance of computed tomography scanner beams in diagnostic radiology

    International Nuclear Information System (INIS)

    Lindskoug, B.A.

    1989-01-01

    The number of computed tomography (CT) scanners in diagnostic radiology is increasing, to the extent that they are now found in relatively small hospitals. These hospitals do not have local physicists available and so methods must be developed to allow quality assurance to be carried out at distant laboratories. Several different types of solid water phantoms are available with various built-in test objects that may supply sufficient information about the many parameters that must be checked. The dose distributions, however, are usually not so well considered, although the connection between image quality and absorbed dose must be known for optimal use of a CT scanner. By introducing thermoluminescent dosemeters (TLDs) into a commercial phantom (RMI), it was possible to measure the absorbed dose profile and the line integral of the absorbed dose across the slit. The computer-guided readout of the TLDs gives the absorbed dose, the average dose and half maximum width, absorbed dose curve, and also the line integral of the peak. The only modification of the phantom was five holes, drilled at strategic positions, that did not influence the built-in test objects. This single measurement provides an appropriate monthly quality assurance check of the CT scanner with little extra effort. (author)

  13. Double compression system to increase beam quality in medical linear accelerators

    Science.gov (United States)

    Rajabi, A.; Shokri, B.; Ahmadizadeh, Y.

    2017-06-01

    The modern radiation therapy is now one of the most powerful tools for the treatment of tumors and cancers. During these treatments, the quality of the operation and the clinical requirements are critical. Here in the present work, based on the beam dynamics of the electrons in RF cavities, a new design for enhancing the quality of bunches is proposed. The simulation results show that the new design can increase the quality of the output bunches which consequently increase the quality of the radiotherapy treatment.

  14. Research Productivity and Patent Quality: Measurement with Multiple Indicators

    OpenAIRE

    Lanjouw, Jean O; Schankerman, Mark

    2002-01-01

    We analyse the determinants of the decline in measured research productivity (the patent/R&D ratio) using panel data on manufacturing firms in the U.S. for the period 1980-93. We focus on three factors: the level of demand, the quality of patents, and technological exhaustion. We first develop an index of patent ‘quality’ using detailed information on patents in the U.S. in seven technology fields. Using a factor model, we construct a minimum-variance index based on four patent characteristic...

  15. Long-term stability of beam quality and output of conventional X-ray units

    OpenAIRE

    Fukuda, Atsushi; Matsubara, Kosuke; Miyati, Toshiaki

    2015-01-01

    Conventional diagnostic X-ray units are used for radiographic imaging in many countries. For obtaining entrance surface doses, a numerical dose determination method has been applied in Japan. Although this technique is effective, it has to account for errors, particularly fluctuations, due to the beam quality and output of X-ray tubes. As a part of our quality control procedures, we recorded the entrance surface air kerma, tube voltage, and half-value layer measurements made for four diagnost...

  16. Biochemical quality indices of sorghum genotypes from east Africa ...

    African Journals Online (AJOL)

    Biochemical characteristics assayed for 131 sorghum [Sorghum bicolor (L) Moench] accessions included total starch, amylopectin, amylose, proteins, tannins contents, germination energy and germination capacity. Results indicate that starch contents ranged from 22.8 - 81.2%, amylose from 11.5 - 30.2% while the ...

  17. Propagation of low-quality laser beams in turbulent air: new fast simulation methods and experimental results

    Science.gov (United States)

    Hall, Thomas; Spindler, Gerhard; Becker, Peter; Grünewald, Karin; Pargmann, Carsten; Duschek, Frank

    2017-11-01

    Novel inherently fast methods basing upon fundamental Gaussian modes are presented to numerically simulate the propagation behavior of a low-quality laser beam, i.e., a beam characterized by a high quality factor M^2, in turbulent air. Actually, for a given initial diameter, beam wandering and spread at the target position is calculated. Test results are checked against respective simulations using higher-order mode beams having clearly defined quality factors and nearly perfect agreement is demonstrated. Experiments performed on the German Aerospace Center (DLR) laser test range at Lampoldshausen near Stuttgart satisfactorily accord with the predictions of the proposed simulation techniques.

  18. [Study on the optimization of monitoring indicators of drinking water quality during health supervision].

    Science.gov (United States)

    Ye, Bixiong; E, Xueli; Zhang, Lan

    2015-01-01

    To optimize non-regular drinking water quality indices (except Giardia and Cryptosporidium) of urban drinking water. Several methods including drinking water quality exceed the standard, the risk of exceeding standard, the frequency of detecting concentrations below the detection limit, water quality comprehensive index evaluation method, and attribute reduction algorithm of rough set theory were applied, redundancy factor of water quality indicators were eliminated, control factors that play a leading role in drinking water safety were found. Optimization results showed in 62 unconventional water quality monitoring indicators of urban drinking water, 42 water quality indicators could be optimized reduction by comprehensively evaluation combined with attribute reduction of rough set. Optimization of the water quality monitoring indicators and reduction of monitoring indicators and monitoring frequency could ensure the safety of drinking water quality while lowering monitoring costs and reducing monitoring pressure of the sanitation supervision departments.

  19. DOE CALiPER Program, Report 20.1 Subjective Evaluation of Beam Quality, Shadow Quality, and Color Quality for LED PAR38 Lamps

    Energy Technology Data Exchange (ETDEWEB)

    Royer, Michael P.; Poplawski, Michael E.; Miller, Naomi J.

    2013-10-01

    This report focuses on human-evaluated characteristics, including beam quality, shadow quality, and color quality. Using a questionnaire that included rank ordering, opinions on 27 of the Report 20 PAR38 lamps were gathered during a demonstration event for members of the local Illuminating Engineering Society (IES) chapter. This was not a rigorous scientific experiment, and the data should not be extrapolated beyond the scope of the demonstration. The results suggest that many of the LED products compared favorably to halogen PAR38 benchmarks in all attributes considered. LED lamps using a single-emitter design were generally preferred for their beam quality and shadow quality, and the IES members ranking of color quality did not always match the rank according to the color rendering index (CRI).

  20. CALiPER Report 20.1: Subjective Evaluation of Beam Quality, Shadow Quality, and Color Quality for LED PAR38 Lamps

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2013-11-07

    This report focuses on human-evaluated characteristics, including beam quality, shadow quality, and color quality. Using a questionnaire that included rank-ordering, opinions on 27 of the Report 20 PAR38 lamps were gathered during a demonstration event for members of the local Illuminating Engineering Society (IES) chapter. This was not a rigorous scientific experiment, and the data should not be extrapolated beyond the scope of the demonstration. The results suggest that many of the LED products compared favorably to halogen PAR38 benchmarks in all attributes considered. LED lamps using a single-emitter design were generally preferred for their beam quality and shadow quality, and the IES members' ranking of color quality did not always match the rank according to the color rendering index (CRI).

  1. Assessment of ecological quality of coastal lagoons with a combination of phytobenthic and water quality indices.

    Science.gov (United States)

    Christia, Chrysoula; Giordani, Gianmarco; Papastergiadou, Eva

    2014-09-15

    Coastal lagoons are ecotones between continents and the sea. Coastal lagoons of Western Greece, subjected to different human pressures, were classified into four different types based on their hydromorphological characteristics and monitored over a three year period for their biotic and abiotic features. Six ecological indices based on water quality parameters (TSI-Chl-a, TSI-TP, TRIX), benthic macrophytes (E-MaQI, EEI-c) and an integrated index TWQI, were applied to assess the ecological status of studied lagoons under real conditions. The trophic status ranged from oligotrophic to hypertrophic according to the index applied. The ecological quality of transitional water ecosystems can be better assessed by using indices based on benthic macrophytes as changes in abundance and diversity of sensitive and tolerant species are the first evidence of incoming eutrophication. The multi-parametric index TWQI can be considered appropriate for the ecological assessment of these ecosystems due to its robustness and the simple application procedure. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. The choice of indicators to assess the quality of educational services of the institution

    Directory of Open Access Journals (Sweden)

    Елена Егоровна Кулик

    2015-07-01

    Full Text Available On the basis of well-known international and national systems of indicators that make it possible to assess the development of the education system, educational system identified indicators to assess the quality of educational services to secondary schools. In the article the author formulated the original definition of concepts such as quality, quality of education, educational service, quality of education services and indicators of education.

  3. [Association between the percentages of typical forms, acrosome abnormalities and the multiple anomalies indices: potential quality indicators?].

    Science.gov (United States)

    Laudat, Antoine; Lecourbe, Karine; Joyeux, Claudine; Burc-Struxiano, Laurence

    2012-01-01

    In addition to NF EN ISO 15189, the second version of "GBEA AMP", published in the official journal of the French Republic, had set for "AMP" exams, the actions to be implemented in order to achieve an efficient quality management system. As part of continuous improvement of quality, and besides our external and internal quality systems, we have been developping indicators that will allow an early detection of potential drifts within operators performing sperm morphology testing. We have extracted nearly 1900 sperm morphology tests from our database. These tests were performed by three operators. The analysis of the data collected has shown a cross correlation between the percentages of typical forms, malformative acrosomes and "MAI". We have been using these correlations as quality indicators in our laboratory in order to highlight any potential drift in reading sperm morphology tests.

  4. CHEMICAL WATER QUALITY INDICATORS IN BASIN FOREST PARCZEW

    Directory of Open Access Journals (Sweden)

    Antoni Grzywna

    2014-10-01

    Full Text Available This paper presents the characteristics of the chemistry of surface and ground water in the bottom of the river valley reclaimed Ochoza. Drained grassland accounts for 20% of the total catchment area and are located on organic soils in the valley Tyśmienica classified to the Natura 2000 sites. Analysis of physico-chemical properties of water are to assess the effects of anthropogenic transformation and identify factors that influence water quality in the study area. Water samples were collected in the years 2011–2012 in several points. The walls were characterized by surface water stagnant in the trenches, in July, blueberry plantation. Characterized by the highest quality of surface water runoff river with the test object. Occurring here throughout the growing season water flow reed growing on the bed and temporary impoundment of water contribute to the self-cleaning effect of water. Conducted at different times of the growing season (winter, spring, summer, autumn of water chemistry analysis allows to assess the impact of vegetation on the process of self-purification of water. Based on the survey it was found that the river is reduced by 26% BOD 5, COD by 37%, 12% phosphate and potassium by 13%. Concurrently, an increase in the content of nitrogen compounds – ammonia at 27% and 15% nitrate. The increase in the content of nitrogen compounds is particularly evident in the bottom of the object, which is probably associated with the deep trench causing excessive drying of the soil. The highest values of pollutants were recorded mostly in the spring probably due to the outflow of water from the drans.

  5. A comparison of physical image quality indices and observer performance in the radiographic detection of nylon beads

    International Nuclear Information System (INIS)

    Loo, L.-N.D.; Doi, K.; Metz, C.E.

    1984-01-01

    Although various models have been proposed in an attempt to predict the usefulness of a radiographic image in terms of its physical characteristics, no previous work has shown whether a single physical image quality index, such as a signal-to-noise ratio, can reliably predict the performance of a human observer over a broad range of image characteristics. The authors studied the relationship between physical and visual image quality for the task of detecting nylon beads in radiographs. Thirty-seven imaging cases with different combinations of physical image characteristics were considered, including variations in object size and magnification, x-ray beam quality, screen-film system, screen-film contact, film density and illumination, and viewing distance. For each imaging case, visual image quality was quantified in terms of observer performance in a 2AFC visual detection experiment. Physical image quality indices were calculated according to eight different models of the detection process; these indices combined data regarding object size and attenuation, screen-film system MTF, film gradient, noise Wiener spectrum, and visual system response. The results of this work indicate that, for the conditions studied, human observer detection performance most closely resembles that of a sub-optimal statistical decision process. (author)

  6. A fuzzy-logic based decision-making approach for identification of groundwater quality based on groundwater quality indices.

    Science.gov (United States)

    Vadiati, M; Asghari-Moghaddam, A; Nakhaei, M; Adamowski, J; Akbarzadeh, A H

    2016-12-15

    Due to inherent uncertainties in measurement and analysis, groundwater quality assessment is a difficult task. Artificial intelligence techniques, specifically fuzzy inference systems, have proven useful in evaluating groundwater quality in uncertain and complex hydrogeological systems. In the present study, a Mamdani fuzzy-logic-based decision-making approach was developed to assess groundwater quality based on relevant indices. In an effort to develop a set of new hybrid fuzzy indices for groundwater quality assessment, a Mamdani fuzzy inference model was developed with widely-accepted groundwater quality indices: the Groundwater Quality Index (GQI), the Water Quality Index (WQI), and the Ground Water Quality Index (GWQI). In an effort to present generalized hybrid fuzzy indices a significant effort was made to employ well-known groundwater quality index acceptability ranges as fuzzy model output ranges rather than employing expert knowledge in the fuzzification of output parameters. The proposed approach was evaluated for its ability to assess the drinking water quality of 49 samples collected seasonally from groundwater resources in Iran's Sarab Plain during 2013-2014. Input membership functions were defined as "desirable", "acceptable" and "unacceptable" based on expert knowledge and the standard and permissible limits prescribed by the World Health Organization. Output data were categorized into multiple categories based on the GQI (5 categories), WQI (5 categories), and GWQI (3 categories). Given the potential of fuzzy models to minimize uncertainties, hybrid fuzzy-based indices produce significantly more accurate assessments of groundwater quality than traditional indices. The developed models' accuracy was assessed and a comparison of the performance indices demonstrated the Fuzzy Groundwater Quality Index model to be more accurate than both the Fuzzy Water Quality Index and Fuzzy Ground Water Quality Index models. This suggests that the new hybrid fuzzy

  7. Control of the offset printing image quality indices

    Science.gov (United States)

    Varepo, L. G.; Brazhnikov, A. Yu; Volinsky, A. A.; Nagornova, I. V.; Kondratov, A. P.

    2017-06-01

    The problem of assessing printing quality is urgent nowadays and requires informative adaptation and development methods. The study of “printing ink -substrate” boundary, taking into account a great variety of printing ink, is of high scientific and applied interest. The paper presents research results of the printouts made on the coated paper by the offset printing method. Visualization of the components distribution of offset ink in substrate surface and volumetric layers of the substrate is presented. Based on the scanning electron microscopy and energy dispersive spectra analysis of the printouts cross-sections, colorimetric parameters and the character of ink layers distribution in pores of the paper, coated layers of two coloured inks at different applications during printing, are compared. The tendency of bigger distortion of the required colour at higher depth of the ink penetration is observed. The obtained data can be used for the values of pre-distortions, predefined in the pre-press, so that the printing ink can be chosen depending on the required reproduction accuracy.

  8. Chlorophyll as an indicator of green tea quality

    Directory of Open Access Journals (Sweden)

    Martina Ošťádalová

    2014-01-01

    Full Text Available The objective of this work was to study the changes in chlorophyll contents in green teas stored under different conditions and to suggest the most suitable way and length of green tea storage. A secondary aim was to evaluate the possibility of using the chlorophyll content as an indicator of tea freshness. Samples for analysis were obtained from a range of tea-growing regions. Chlorophyll contents were measured using UV-vis spectrophotometry. Chlorophyll absorbance was measured at 642.5 and 660 nm. Prior to storage, chlorophyll concentration in teas ranged from 1.12 to 1.89 mg per 1 g of tea, which corresponded to data given by other authors. Storage was found to lead to a decline in chlorophyll concentration. From the 6th month of storage onwards, a significant decrease (P < 0.05 was observed in all samples, irrespective of storage conditions. Based on the findings of this study, original and metal packaging can be considered the most chlorophyll-friendly. On the other hand, glass and paper packaging stored in direct daylight were found to have the strongest impact on chlorophyll concentration. Overall, it can be concluded that the storage time can have a strong influence on oolong green tea colour as an important qualitative variable. Thus, the shelf-life of tea should be shorter than the 12 months claimed by most manufacturers. Once the relationship between changes in chlorophyll concentration and length of the storage period had been established, the chlorophyll content was suggested as an indicator of the storage time (freshness of a tea substance.

  9. Quality indicators for safe medication preparation and administration: a systematic review.

    Directory of Open Access Journals (Sweden)

    Marian Smeulers

    Full Text Available One-third of all medication errors causing harm to hospitalized patients occur in the medication preparation and administration phase, which is predominantly a nursing activity. To monitor, evaluate and improve the quality and safety of this process, evidence-based quality indicators can be used.The aim of study was to identify evidence-based quality indicators (structure, process and outcome for safe in-hospital medication preparation and administration.MEDLINE, EMBASE and CINAHL were searched for relevant studies published up to January 2015. Additionally, nine databases were searched to identify relevant grey literature. Two reviewers independently selected studies if (1 the method for quality indicator development combined a literature search with expert panel opinion, (2 the study contained quality indicators on medication safety, and (3 any of the quality indicators were applicable to hospital medication preparation and administration. A multidisciplinary team appraised the studies independently using the AIRE instrument, which contains four domains and 20 items. Quality indicators applicable to in-hospital medication preparation and administration were extracted using a structured form.The search identified 1683 studies, of which 64 were reviewed in detail and five met the inclusion criteria. Overall, according to the AIRE domains, all studies were clear on purpose; most of them applied stakeholder involvement and used evidence reasonably; usage of the indicator in practice was scarcely described. A total of 21 quality indicators were identified: 5 structure indicators (e.g. safety management and high alert medication, 11 process indicators (e.g. verification and protocols and 5 outcome indicators (e.g. harm and death. These quality indicators partially cover the 7 rights.Despite the relatively small number of included studies, the identified quality indicators can serve as an excellent starting point for further development of nursing

  10. Quality of 'Climax' blueberries after low dosage electron beam irradiation

    International Nuclear Information System (INIS)

    Miller, W.R.; McDonald, R.E.; McCollum, T.G.; Smittle, B.J.

    1994-01-01

    Fruit of 'Climax' rabbiteye blueberries (Vaccinium ashei Reade) were irradiated by a linear accelerator at 0, 0.25, 0.5, 0.75, 1.0, and 1.25 kGy and evaluated for various quality attributes after storage for 1, 3, 7, or 14 days at 1C plus 2 days at 15C, respectively. Weight loss increased during storage and averaged 4.2% after the final inspection and was not affected by irradiation dosage. About 5% of total berries were decayed after 14 days at 1C, about 6% after the final inspection at 15C, but decay was not affected by the level of irradiation. Electrolyte leakage, skin color, total soluble solids, acidity, and pH were also not affected by irradiation dosage. There was a significant decline in berry firmness, flavor, and texture as dosage increased. Berries treated at 1.0 kGy or above were softer and had lower flavor and texture preference scores than berries treated at lower dosages or nontreated berries

  11. Development of on package indicator sensor for real-time monitoring of meat quality

    Directory of Open Access Journals (Sweden)

    Vivek Shukla

    2015-03-01

    Full Text Available Aim: The aim was to develop an indicator sensor for real-time monitoring of meat quality and to compare the response of indicator sensor with meat quality parameters at ambient temperature. Materials and Methods: Indicator sensor was prepared using bromophenol blue (1% w/v as indicator solution and filter paper as indicator carrier. Indicator sensor was fabricated by coating indicator solution onto carrier by centrifugation. To observe the response of indicator sensor buffalo meat was packed in polystyrene foam trays covered with PVC film and indicator sensor was attached to the inner side of packaging film. The pattern of color change in indicator sensor was monitored and compared with meat quality parameters viz. total volatile basic nitrogen, D-glucose, standard plate count and tyrosine value to correlate ability of indicator sensor for its suitability to predict the meat quality and storage life. Results: The indicator sensor changed its color from yellow to blue starting from margins during the storage period of 24 h at ambient temperature and this correlated well with changes in meat quality parameters. Conclusions: The indicator sensor can be used for real-time monitoring of meat quality as the color of indicator sensor changed from yellow to blue starting from margins when meat deteriorates with advancement of the storage period. Thus by observing the color of indicator sensor quality of meat and shelf life can be predicted.

  12. Development of on package indicator sensor for real-time monitoring of meat quality

    Science.gov (United States)

    Shukla, Vivek; Kandeepan, G.; Vishnuraj, M. R.

    2015-01-01

    Aim: The aim was to develop an indicator sensor for real-time monitoring of meat quality and to compare the response of indicator sensor with meat quality parameters at ambient temperature. Materials and Methods: Indicator sensor was prepared using bromophenol blue (1% w/v) as indicator solution and filter paper as indicator carrier. Indicator sensor was fabricated by coating indicator solution onto carrier by centrifugation. To observe the response of indicator sensor buffalo meat was packed in polystyrene foam trays covered with PVC film and indicator sensor was attached to the inner side of packaging film. The pattern of color change in indicator sensor was monitored and compared with meat quality parameters viz. total volatile basic nitrogen, D-glucose, standard plate count and tyrosine value to correlate ability of indicator sensor for its suitability to predict the meat quality and storage life. Results: The indicator sensor changed its color from yellow to blue starting from margins during the storage period of 24 h at ambient temperature and this correlated well with changes in meat quality parameters. Conclusions: The indicator sensor can be used for real-time monitoring of meat quality as the color of indicator sensor changed from yellow to blue starting from margins when meat deteriorates with advancement of the storage period. Thus by observing the color of indicator sensor quality of meat and shelf life can be predicted. PMID:27047103

  13. Mixing layer height as an indicator for urban air quality?

    Science.gov (United States)

    Geiß, Alexander; Wiegner, Matthias; Bonn, Boris; Schäfer, Klaus; Forkel, Renate; von Schneidemesser, Erika; Münkel, Christoph; Chan, Ka Lok; Nothard, Rainer

    2017-08-01

    The mixing layer height (MLH) is a measure for the vertical turbulent exchange within the boundary layer, which is one of the controlling factors for the dilution of pollutants emitted near the ground. Based on continuous MLH measurements with a Vaisala CL51 ceilometer and measurements from an air quality network, the relationship between MLH and near-surface pollutant concentrations has been investigated. In this context the uncertainty of the MLH retrievals and the representativeness of ground-based in situ measurements are crucial. We have investigated this topic by using data from the BAERLIN2014 campaign in Berlin, Germany, conducted from June to August 2014. To derive the MLH, three versions of the proprietary software BL-VIEW and a novel approach COBOLT were compared. It was found that the overall agreement is reasonable if mean diurnal cycles are considered. The main advantage of COBOLT is the continuous detection of the MLH with a temporal resolution of 10 min and a lower number of cases when the residual layer is misinterpreted as mixing layer. We have calculated correlations between MLH as derived from the different retrievals and concentrations of pollutants (PM10, O3 and NOx) for different locations in the metropolitan area of Berlin. It was found that the correlations with PM10 are quite different for different sites without showing a clear pattern, whereas the correlation with NOx seems to depend on the vicinity of emission sources in main roads. In the case of ozone as a secondary pollutant, a clear correlation was found. We conclude that the effects of the heterogeneity of the emission sources, chemical processing and mixing during transport exceed the differences due to different MLH retrievals. Moreover, it seems to be unrealistic to find correlations between MLH and near-surface pollutant concentrations representative for a city like Berlin (flat terrain), in particular when traffic emissions are dominant. Nevertheless it is worthwhile to use

  14. Mixing layer height as an indicator for urban air quality?

    Directory of Open Access Journals (Sweden)

    A. Geiß

    2017-08-01

    Full Text Available The mixing layer height (MLH is a measure for the vertical turbulent exchange within the boundary layer, which is one of the controlling factors for the dilution of pollutants emitted near the ground. Based on continuous MLH measurements with a Vaisala CL51 ceilometer and measurements from an air quality network, the relationship between MLH and near-surface pollutant concentrations has been investigated. In this context the uncertainty of the MLH retrievals and the representativeness of ground-based in situ measurements are crucial. We have investigated this topic by using data from the BAERLIN2014 campaign in Berlin, Germany, conducted from June to August 2014. To derive the MLH, three versions of the proprietary software BL-VIEW and a novel approach COBOLT were compared. It was found that the overall agreement is reasonable if mean diurnal cycles are considered. The main advantage of COBOLT is the continuous detection of the MLH with a temporal resolution of 10 min and a lower number of cases when the residual layer is misinterpreted as mixing layer. We have calculated correlations between MLH as derived from the different retrievals and concentrations of pollutants (PM10, O3 and NOx for different locations in the metropolitan area of Berlin. It was found that the correlations with PM10 are quite different for different sites without showing a clear pattern, whereas the correlation with NOx seems to depend on the vicinity of emission sources in main roads. In the case of ozone as a secondary pollutant, a clear correlation was found. We conclude that the effects of the heterogeneity of the emission sources, chemical processing and mixing during transport exceed the differences due to different MLH retrievals. Moreover, it seems to be unrealistic to find correlations between MLH and near-surface pollutant concentrations representative for a city like Berlin (flat terrain, in particular when traffic emissions are dominant. Nevertheless it is

  15. Evaluation of various approaches for assessing dose indicators and patient organ doses resulting from radiotherapy cone-beam CT.

    Science.gov (United States)

    Rampado, Osvaldo; Giglioli, Francesca Romana; Rossetti, Veronica; Fiandra, Christian; Ragona, Riccardo; Ropolo, Roberto

    2016-05-01

    The aim of this study was to evaluate various approaches for assessing patient organ doses resulting from radiotherapy cone-beam CT (CBCT), by the use of thermoluminescent dosimeter (TLD) measurements in anthropomorphic phantoms, a Monte Carlo based dose calculation software, and different dose indicators as presently defined. Dose evaluations were performed on a CBCT Elekta XVI (Elekta, Crawley, UK) for different protocols and anatomical regions. The first part of the study focuses on using pcxmc software (pcxmc 2.0, STUK, Helsinki, Finland) for calculating organ doses, adapting the input parameters to simulate the exposure geometry, and beam dose distribution in an appropriate way. The calculated doses were compared to readouts of TLDs placed in an anthropomorphic Rando phantom. After this validation, the software was used for analyzing organ dose variability associated with patients' differences in size and gender. At the same time, various dose indicators were evaluated: kerma area product (KAP), cumulative air-kerma at the isocenter (Kair), cone-beam dose index, and central cumulative dose. The latter was evaluated in a single phantom and in a stack of three adjacent computed tomography dose index phantoms. Based on the different dose indicators, a set of coefficients was calculated to estimate organ doses for a range of patient morphologies, using their equivalent diameters. Maximum organ doses were about 1 mGy for head and neck and 25 mGy for chest and pelvis protocols. The differences between pcxmc and TLDs doses were generally below 10% for organs within the field of view and approximately 15% for organs at the boundaries of the radiation beam. When considering patient size and gender variability, differences in organ doses up to 40% were observed especially in the pelvic region; for the organs in the thorax, the maximum differences ranged between 20% and 30%. Phantom dose indexes provided better correlation with organ doses than Kair and KAP, with average

  16. Influence of yeast strain on Shiraz wine quality indicators.

    Science.gov (United States)

    Holt, Helen; Cozzolino, Daniel; McCarthy, Jane; Abrahamse, Caroline; Holt, Sylvester; Solomon, Mark; Smith, Paul; Chambers, Paul J; Curtin, Chris

    2013-08-01

    Wine styles are defined by complex and highly diverse chemical compositions. Evidence suggests that some of this complexity is determined by the choice of yeast strain used in fermentation. There are hundreds of different commercially available wine yeast strains that, potentially, provide a means by which winemakers can tailor their wines for different consumer market segments. In this study we evaluated the impacts of fermenting Shiraz must with different yeast strains, with a focus on chemical composition and tannin content of the finished wines. Principal Component Analysis (PCA) of the wines indicated that choice of yeast strain had a strong influence on a number of wine compositional parameters, including tannin. In three fermentation experiments, across two vintages and using different winemaking protocols, a compelling case for yeast strain 'signature' was evident. The results demonstrate that there is an opportunity to use commercial wine yeast diversity to modulate red wine composition and, by implication, the style of finished wines. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Gridded Population of the World, Version 4 (GPWv4): Data Quality Indicators

    Data.gov (United States)

    National Aeronautics and Space Administration — Gridded Population of the World, Version 4 (GPWv4) Data Quality Indicators consist of three data layers created to provide additional information about the quality...

  18. The impact of removing financial incentives from clinical quality indicators: longitudinal analysis of four Kaiser Permanente indicators.

    NARCIS (Netherlands)

    Lester, H.; Schmittdiel, J.; Selby, J.; Fireman, B.; Campbell, S.M.; Lee, J.; Whippy, A.; Madvig, P.

    2010-01-01

    OBJECTIVE: To evaluate the effect of financial incentives on four clinical quality indicators common to pay for performance plans in the United Kingdom and at Kaiser Permanente in California. DESIGN: Longitudinal analysis. SETTING: 35 medical facilities of Kaiser Permanente Northern California,

  19. Quality indicators in intensive care medicine for Germany – third edition 2017

    Directory of Open Access Journals (Sweden)

    Kumpf, Oliver

    2017-08-01

    Full Text Available Quality improvement in medicine is depending on measurement of relevant quality indicators. The quality indicators for intensive care medicine of the German Interdisciplinary Society of Intensive Care Medicine (DIVI from the year 2013 underwent a scheduled evaluation after three years. There were major changes in several indicators but also some indicators were changed only minimally. The focus on treatment processes like , , and , as well as the number of 10 indicators were not changed. Most topics remained except for which was introduced instead of . was added as an outcome indicator. These quality indicators are used in the peer review in intensive care, a method endorsed by the DIVI. A validity period of three years is planned for the quality indicators.

  20. 77 FR 32975 - AHRQ Workgroups on ICD-10-CM/PCS Conversion of Quality Indicators (QIs)

    Science.gov (United States)

    2012-06-04

    ...; Expertise in ICD-9-CM and/or ICD-10-CM/PCS coding; Expertise in hospital quality improvement, patient safety... Indicators (PQI), the Inpatient Quality Indicators, the Patient Safety Indicators (PSI), and the Pediatric... musculoskeletal disease, obstetrics and gynecologic disease, surgery, critical care and pulmonary disease...

  1. Quality of Life Indicators for Individuals with Intellectual Disabilities: Extending Current Practice

    Science.gov (United States)

    Brown, Ivan; Hatton, Chris; Emerson, Eric

    2013-01-01

    Quality of life is a social construct that is measured by what are considered to be its most appropriate indicators. Quality of life measurement in intellectual disability reflects a variety of indicators, often grouped under life domains. Subjective and objective methods of measuring indicators each have strengths and drawbacks, but it is…

  2. Pilot Quality Control Program for Audit RT External Beams at Mexican Hospitals

    International Nuclear Information System (INIS)

    Alvarez R, J T; Tovar M, V M

    2008-01-01

    A pilot quality control program for audit 18 radiotherapy RT external beams at 13 Mexican hospitals is described--for eleven 60 Co beams and seven photon beams of 6, 10 and 15 MV from accelerators. This program contains five parts: a) Preparation of the TLD-100 powder: washing, drying and annealing (one hour 400 deg. C plus 24 hrs 80 deg. C). b) Sending two IAEA type capsules to the hospitals for irradiation at the hospital to a nominal D W = 2 Gy·c) Preparation at the SSDL of ten calibration curves CC in the range of 0.5 Gy to 6 Gy in terms of absorbed dose to water D W for 60 Co with traceability to primary laboratory NRC (Canada), according to a window irradiation: 26/10/2007-7/12/2007. d) Reading all capsules that match their hospital time irradiation and the SSDL window irradiation. f) Evaluation of the Dw imparted by the hospitals

  3. Pilot Quality Control Program for Audit RT External Beams at Mexican Hospitals

    Science.gov (United States)

    Álvarez R., J. T.; Tovar M., V. M.

    2008-08-01

    A pilot quality control program for audit 18 radiotherapy RT external beams at 13 Mexican hospitals is described—for eleven 60 Co beams and seven photon beams of 6, 10 and 15 MV from accelerators. This program contains five parts: a) Preparation of the TLD-100 powder: washing, drying and annealing (one hour 400 °C plus 24 hrs 80 °C). b) Sending two IAEA type capsules to the hospitals for irradiation at the hospital to a nominal DW = 2 Gy ṡ c ) Preparation at the SSDL of ten calibration curves CC in the range of 0.5 Gy to 6 Gy in terms of absorbed dose to water DW for 60 Co with traceability to primary laboratory NRC (Canada), according to a window irradiation: 26/10/2007-7/12/2007. d) Reading all capsules that match their hospital time irradiation and the SSDL window irradiation. f) Evaluation of the Dw imparted by the hospitals.

  4. Development of disease-specific quality indicators for danish chiropractic patients with low back pain

    DEFF Research Database (Denmark)

    Sorensen, Line P; Krog, Birgitte R; Kongsted, Alice

    2011-01-01

    The purpose of this study is to develop disease-specific quality indicators for Danish chiropractic patients with low back pain (LBP) as an initial effort to include chiropractors in the Danish Health Care Quality Programme.......The purpose of this study is to develop disease-specific quality indicators for Danish chiropractic patients with low back pain (LBP) as an initial effort to include chiropractors in the Danish Health Care Quality Programme....

  5. Are trophic and diversity indices based on macrophyte communities pertinent tools to monitor water quality?

    Science.gov (United States)

    Thiebaut, Gabrielle; Guérold, François; Muller, Serge

    2002-08-01

    Diversity and trophic indices based on macrophyte communities were calculated to test their pertinence to monitoring water quality in the Northern Vosges (NE of France). Highly significant correlations were found between the four tested chemical variables (bicarbonate, calcium, phosphorus and ammonium nitrogen) and trophic indices and between them and abundance and richness. Trophic indices and McIntosh's index appeared to be more effective in predicting water quality than diversity indices. Diversity indices do not necessarily provide any direct information on the quality or degree of degradation of the environment from which the sample was taken, whereas trophic indices do.

  6. Influence of data quality on computed Dutch hospital quality indicators: a case study in colorectal cancer surgery

    NARCIS (Netherlands)

    Dentler, Kathrin; Cornet, Ronald; ten Teije, Annette; Tanis, Pieter; Klinkenbijl, Jean; Tytgat, Kristien; de Keizer, Nicolette

    2014-01-01

    Background: Our study aims to assess the influence of data quality on computed Dutch hospital quality indicators, and whether colorectal cancer surgery indicators can be computed reliably based on routinely recorded data from an electronic medical record (EMR). Methods: Cross-sectional study in a

  7. Application of Water Quality and Ecology Indices of Benthic Macroinvertebrate to Evaluate Water Quality of Tertiary Irrigation in Malang District

    Directory of Open Access Journals (Sweden)

    Desi Kartikasari

    2013-12-01

    Full Text Available This research aims to determine the water quality of tertiary irrigation in several subdistricts in Malang, namely Kepanjen, Karangploso, and Tumpang. The water quality depends on the water quality indices (National Sanitation Foundation’s-NSF Indices and O’Connor’s Indices based on variables TSS, TDS, pH, DO, and Nitrate concentrate and ecological indices of benthic macroinvertebrate (Diversity Indices Shannon-Wiener, Hilsenhof Biotic Indices-HBI, Average Score per Taxon-ASPT which is calculated by Biological Monitoring Working Party-BMWP, Ephemeroptera Indices, Plecoptera, Trichoptera-EPT. Observation of the physico-chemical water quality and benthic macroinvertebrate on May 2012 to April 2013. The sampling in each subdistrict was done at two selected stations in tertiary irrigation channel with three plot at each station. The data of physico-chemical quality of water were used to calculate the water quality indices, while the benthic macroinvertebrate data were used to calculate the ecological indices. The research findings showed that 27 taxa of benthic macroinvertebrates belong 10 classes were found in the three subdistrict. The pH, DO, Nitrate, TSS and TDS in six tertiary irrigation channels in Malang still met the water quality standards based on Government Regulation No. 82 of 2001 on Management of Water Quality and Water Pollution Control Class III. Based on NSF-WQI indices and O'Connor's Indices, water qualities in these irrigation channels were categorized into medium or moderate (yellow to good (green category. However, based on benthic macroinvertebrate communities which was used to determine the HBI, the water quality in the irrigation channels were categorized into the fair category (fairly significant organic pollution to fairly poor (significant organic pollution, while based on the value of ASPT, the water were categorized into probable moderate pollution to probable severe pollution. The irrigation water which was

  8. Image simulation and a model of noise power spectra across a range of mammographic beam qualities

    Energy Technology Data Exchange (ETDEWEB)

    Mackenzie, Alistair, E-mail: alistairmackenzie@nhs.net; Dance, David R.; Young, Kenneth C. [National Coordinating Centre for the Physics of Mammography, Royal Surrey County Hospital, Guildford GU2 7XX, United Kingdom and Department of Physics, University of Surrey, Guildford GU2 7XH (United Kingdom); Diaz, Oliver [Centre for Vision, Speech and Signal Processing, Faculty of Engineering and Physical Sciences, University of Surrey, Guildford GU2 7XH, United Kingdom and Computer Vision and Robotics Research Institute, University of Girona, Girona 17071 (Spain)

    2014-12-15

    Purpose: The aim of this work is to create a model to predict the noise power spectra (NPS) for a range of mammographic radiographic factors. The noise model was necessary to degrade images acquired on one system to match the image quality of different systems for a range of beam qualities. Methods: Five detectors and x-ray systems [Hologic Selenia (ASEh), Carestream computed radiography CR900 (CRc), GE Essential (CSI), Carestream NIP (NIPc), and Siemens Inspiration (ASEs)] were characterized for this study. The signal transfer property was measured as the pixel value against absorbed energy per unit area (E) at a reference beam quality of 28 kV, Mo/Mo or 29 kV, W/Rh with 45 mm polymethyl methacrylate (PMMA) at the tube head. The contributions of the three noise sources (electronic, quantum, and structure) to the NPS were calculated by fitting a quadratic at each spatial frequency of the NPS against E. A quantum noise correction factor which was dependent on beam quality was quantified using a set of images acquired over a range of radiographic factors with different thicknesses of PMMA. The noise model was tested for images acquired at 26 kV, Mo/Mo with 20 mm PMMA and 34 kV, Mo/Rh with 70 mm PMMA for three detectors (ASEh, CRc, and CSI) over a range of exposures. The NPS were modeled with and without the noise correction factor and compared with the measured NPS. A previous method for adapting an image to appear as if acquired on a different system was modified to allow the reference beam quality to be different from the beam quality of the image. The method was validated by adapting the ASEh flat field images with two thicknesses of PMMA (20 and 70 mm) to appear with the imaging characteristics of the CSI and CRc systems. Results: The quantum noise correction factor rises with higher beam qualities, except for CR systems at high spatial frequencies, where a flat response was found against mean photon energy. This is due to the dominance of secondary quantum noise

  9. Assessment of emergency general surgery care based on formally developed quality indicators.

    Science.gov (United States)

    Ingraham, Angela; Nathens, Avery; Peitzman, Andrew; Bode, Allison; Dorlac, Gina; Dorlac, Warren; Miller, Preston; Sadeghi, Mahsa; Wasserman, Deena D; Bilimoria, Karl

    2017-08-01

    Emergency general surgery outcomes vary widely across the United States. The utilization of quality indicators can reduce variation and assist providers in administering care aligned with established recommendations. Previous quality indicators have not focused on emergency general surgery patients. We identified indicators of high-quality emergency general surgery care and assessed patient- and hospital-level compliance with these indicators. We utilized a modified Delphi technique (RAND Appropriateness Methodology) to develop quality indicators. Through 2 rankings, an expert panel ranked potential quality indicators for validity. We then examined historic compliance with select quality indicators after 4 nonelective procedures (cholecystectomy, appendectomy, colectomy, small bowel resection) at 4 academic centers. Of 25 indicators rated as valid, 13 addressed patient-level quality and 12 addressed hospital-level quality. Adherence with 18 indicators was assessed. Compliance with performing a cholecystectomy for acute cholecystitis within 72 hours of symptom onset ranged from 45% to 76%. Compliance with surgery start times within 3 hours from the decision to operate for uncontained perforated viscus ranged from 20% to 100%. Compliance with exploration of patients with small bowel obstructions with ischemia/impending perforation within 3 hours of the decision to operate was 0% to 88%. For 3 quality indicators (auditing 30-day unplanned readmissions/operations for patients previously managed nonoperatively, monitoring time to source control for intra-abdominal infections, and having protocols for bypass/transfer), none of the hospitals were compliant. Developing indicators for providers to assess their performance provides a foundation for specific initiatives. Adherence to quality indicators may improve the quality of emergency general surgery care provided for which current outcomes are potentially modifiable. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Impact of coherent synchrotron radiation on beam qualities in a Chicane

    International Nuclear Information System (INIS)

    Xiang Dao; Huang Wenhui; He Xiaozhong

    2004-01-01

    When the bunch goes through a Chicane, the energy will be redistributed within the bunch due to CSR (coherent synchrotron radiation), which would cause nonlinearity. Present theory states that this nonlinearity would add a huge amount to emittance growth. Based on simulation results, this paper would point out that the theory is only valid under an ideal condition that the bunch initially has no nonlinearity and under some given parameters there could be a cancellation between the nonlinearity caused by CSR and the initial nonlinearity. So under these circumstances authors can expect CSR to improve the beam quality. This paper provides a brief information about CSR and a full estimation of effects of CSR on beam qualities

  11. TU-FG-BRB-12: Real-Time Visualization of Discrete Spot Scanning Proton Therapy Beam for Quality Assurance

    Energy Technology Data Exchange (ETDEWEB)

    Matsuzaki, Y [Proton Beam Therapy Center, Hokkaido University Hospital, Sapporo, Hokkaido (Japan); Jenkins, C; Yang, Y; Xing, L [Stanford University, Stanford, California (United States); Yoshimura, T; Fujii, Y [Hokkaido University Graduate School of Medicine, Sapporo, Hokkaido (Japan); Umegaki, K [Global Institution for Collaborative Research and Education (GI-CoRE), Hokkaido University, Sapporo, Hokkaido (Japan)

    2016-06-15

    Purpose: With the growing adoption of proton beam therapy there is an increasing need for effective and user-friendly tools for performing quality assurance (QA) measurements. The speed and versatility of spot-scanning proton beam (PB) therapy systems present unique challenges for traditional QA tools. To address these challenges a proof-of-concept system was developed to visualize, in real-time, the delivery of individual spots from a spot-scanning PB in order to perform QA measurements. Methods: The PB is directed toward a custom phantom with planar faces coated with a radioluminescent phosphor (Gd2O2s:Tb). As the proton beam passes through the phantom visible light is emitted from the coating and collected by a nearby CMOS camera. The images are processed to determine the locations at which the beam impinges on each face of the phantom. By so doing, the location of each beam can be determined relative to the phantom. The cameras are also used to capture images of the laser alignment system. The phantom contains x-ray fiducials so that it can be easily located with kV imagers. Using this data several quality assurance parameters can be evaluated. Results: The proof-of-concept system was able to visualize discrete PB spots with energies ranging from 70 MeV to 220 MeV. Images were obtained with integration times ranging from 20 to 0.019 milliseconds. If not limited by data transmission, this would correspond to a frame rate of 52,000 fps. Such frame rates enabled visualization of individual spots in real time. Spot locations were found to be highly correlated (R{sup 2}=0.99) with the nozzle-mounted spot position monitor indicating excellent spot positioning accuracy Conclusion: The system was shown to be capable of imaging individual spots for all clinical beam energies. Future development will focus on extending the image processing software to provide automated results for a variety of QA tests.

  12. TU-FG-BRB-12: Real-Time Visualization of Discrete Spot Scanning Proton Therapy Beam for Quality Assurance

    International Nuclear Information System (INIS)

    Matsuzaki, Y; Jenkins, C; Yang, Y; Xing, L; Yoshimura, T; Fujii, Y; Umegaki, K

    2016-01-01

    Purpose: With the growing adoption of proton beam therapy there is an increasing need for effective and user-friendly tools for performing quality assurance (QA) measurements. The speed and versatility of spot-scanning proton beam (PB) therapy systems present unique challenges for traditional QA tools. To address these challenges a proof-of-concept system was developed to visualize, in real-time, the delivery of individual spots from a spot-scanning PB in order to perform QA measurements. Methods: The PB is directed toward a custom phantom with planar faces coated with a radioluminescent phosphor (Gd2O2s:Tb). As the proton beam passes through the phantom visible light is emitted from the coating and collected by a nearby CMOS camera. The images are processed to determine the locations at which the beam impinges on each face of the phantom. By so doing, the location of each beam can be determined relative to the phantom. The cameras are also used to capture images of the laser alignment system. The phantom contains x-ray fiducials so that it can be easily located with kV imagers. Using this data several quality assurance parameters can be evaluated. Results: The proof-of-concept system was able to visualize discrete PB spots with energies ranging from 70 MeV to 220 MeV. Images were obtained with integration times ranging from 20 to 0.019 milliseconds. If not limited by data transmission, this would correspond to a frame rate of 52,000 fps. Such frame rates enabled visualization of individual spots in real time. Spot locations were found to be highly correlated (R 2 =0.99) with the nozzle-mounted spot position monitor indicating excellent spot positioning accuracy Conclusion: The system was shown to be capable of imaging individual spots for all clinical beam energies. Future development will focus on extending the image processing software to provide automated results for a variety of QA tests.

  13. The Global Streamflow Indices and Metadata Archive (GSIM) - Part 2: Quality control, time-series indices and homogeneity assessment

    Science.gov (United States)

    Gudmundsson, Lukas; Do, Hong Xuan; Leonard, Michael; Westra, Seth

    2018-04-01

    This is Part 2 of a two-paper series presenting the Global Streamflow Indices and Metadata Archive (GSIM), which is a collection of daily streamflow observations at more than 30 000 stations around the world. While Part 1 (Do et al., 2018a) describes the data collection process as well as the generation of auxiliary catchment data (e.g. catchment boundary, land cover, mean climate), Part 2 introduces a set of quality controlled time-series indices representing (i) the water balance, (ii) the seasonal cycle, (iii) low flows and (iv) floods. To this end we first consider the quality of individual daily records using a combination of quality flags from data providers and automated screening methods. Subsequently, streamflow time-series indices are computed for yearly, seasonal and monthly resolution. The paper provides a generalized assessment of the homogeneity of all generated streamflow time-series indices, which can be used to select time series that are suitable for a specific task. The newly generated global set of streamflow time-series indices is made freely available with an digital object identifier at https://doi.pangaea.de/10.1594/PANGAEA.887470 and is expected to foster global freshwater research, by acting as a ground truth for model validation or as a basis for assessing the role of human impacts on the terrestrial water cycle. It is hoped that a renewed interest in streamflow data at the global scale will foster efforts in the systematic assessment of data quality and provide momentum to overcome administrative barriers that lead to inconsistencies in global collections of relevant hydrological observations.

  14. Groundwater quality assessment using the water quality pollution indices in Toyserkan Plain

    Directory of Open Access Journals (Sweden)

    Soheil Sobhanardakani

    2017-03-01

    Full Text Available Background: Iran is located within the dry and semi dry regions, thus almost 90% of the required water is secured via the use of groundwater. Owing to the increasing pollution of water resources, this study was performed to evaluate water quality pollution indices for heavy metals (As, Zn, Pb and Cu contamination monitoring in Toyserkan Plain during spring and summer in 2012. Methods: A total of 20 ground water wells were chosen randomly. The samples were filtered (0.45 μm and kept cool in polyethylene bottles. Samples were taken for the analysis of metals, the former was acidified with HNO3 to pH lower than 2. Metal concentrations were determined using ICP-OES. Results: The results revealed that the mean values of contamination index (Cd, heavy metal pollution index (HPI and heavy metal evaluation index (HEI in samples for spring season were -2.81, 9.74 and 1.20, respectively and were -2.67, 9.51 and 1.32, respectively in samples for summer season and this indicates low contamination levels. Comparing the mean concentrations of the evaluated metals with WHO permissible limits demonstrated a significant difference (P < 0.05. Thus, the mean concentrations of the metals were significantly lower than the permissible limits. Conclusion: Although the heavy metal pollution of the ground water in Toyserkan Plain is not higher than permissible limits, the irregular and long-term utilization of agricultural inputs, use of wastewater and sewage sludge in agriculture, over utilization of organic fertilizers and establishment of pollutant industries can threaten the ground water, and cause irreversible damages in this area

  15. Quality indicators for the hospital transfusion chain : A national survey conducted in 100 dutch hospitals

    NARCIS (Netherlands)

    Zijlker-Jansen, Pauline Y.; Janssen, M. P.; van Tilborgh-de Jong, A. J W; Schipperus, M. R.; Wiersum-Osselton, J. C.

    2015-01-01

    Background: The 2011 Dutch Blood Transfusion Guideline for hospitals incorporates seven internal quality indicators for evaluation of the hospital transfusion chain. The indicators aim to measure guideline compliance as shown by the instatement of a hospital transfusion committee and transfusion

  16. EPHT air quality (county PM2.5 and Ozone) indicators, 2001-2006

    Data.gov (United States)

    California Environmental Health Tracking Program — The EPHT air quality indicator files are from a SAS program which calculates the air indicators as developed by CDC's Environmental Public Health Tracking (EPHT) Air...

  17. Application of electron-beam irradiation combined with antioxidants for fermented sausage and its quality characteristic

    Science.gov (United States)

    Lim, D. G.; Seol, K. H.; Jeon, H. J.; Jo, C.; Lee, M.

    2008-06-01

    The effects of various doses of electron-beam irradiation on the changes in microbiological attributes of fermented sausage and the combined effect of electron-beam irradiation and various antioxidants on the oxidative stability and sensory properties during cold storage were investigated. Results indicated that 2 kGy of irradiation was the most effective in manufacturing a fermented sausage, and the addition of rosemary extracts was effective in controlling the production of off-flavor and development of lipid oxidation during cold storage.

  18. High power, high beam quality solid state lasers for materials processing applications

    Energy Technology Data Exchange (ETDEWEB)

    Hackel, L.A.; Dane, C.B.; Hermann, M.R. [and others

    1994-08-01

    The Laser Science and Technology Department at Lawrence Livermore National Laboratory is developing solid state lasers with high average power and high beam quality. Specific systems include a laser to generate 10 to 14 {angstrom} x-rays for proximity print lithography, a 400 mJ, 500 Hz laser for 130 {angstrom} projection lithography and unique systems for speckle imaging, laser radars and medical treatments.

  19. Project outline of high quality electron beam generation at Waseda University

    International Nuclear Information System (INIS)

    Washio, M.; Hama, Y.; Kashiwagi, S.; Kuroda, R.; Kobuki, T.; Hirose, T.

    2000-01-01

    High quality electron beam generation project has been started at Waseda University under the grant of Ministry of Education, named High-Tech Research Center Project. In the project, we will install a laser photo-cathode RF Gun system with 1.6 accelerating structure cells of s-band and a stabilized RF power source. This RF Gun is expected to produce single electron bunch up to 1 or 2nC with around 10ps pulse duration. (author)

  20. SYNTHETIC ANALYSIS OF INDICATORS USED IN THE ANALYSIS OF PRODUCT QUALITY DIFFERENTIATED AND NON-DIFFERENTIATED ON QUALITY CLASSES

    Directory of Open Access Journals (Sweden)

    ECOBICI MIHAELA LOREDANA

    2016-12-01

    Full Text Available Product quality has been and will remain one of the most important indicators of increasing economic and financial performance of a company. Quality is that which ensures the greatest part of the competitiveness of a product or service, this being the result of some important aspects such as: products and services of quality to meet consumers requirements, low costs without affecting the quality level, the performance of contractual obligations, customer satisfaction and last but not least obtaining profit. Research and results concerning this issue will result in the prerequisites in the process for quality assurance that can develop both internally and externally. The purpose of this article lies in the approach and illustration of the aspects of products differentiated and non-differentiated in quality classes. In launching this research I will try to highlight some aspects that most efficiently the indicators mentioned above, indicators that read to what extent a certain product meets the characteristics specified to its destination.

  1. Quality control and radioprotection in dental cone beam computed tomography - case study

    International Nuclear Information System (INIS)

    Rodrigues, Ligiane C.N.; Ferreira, Nadya M.P.D.

    2011-01-01

    The radiological protection in medical and odontologic radiology follows The Order (Portaria) 453/98 of the Ministry of Health, which presents the minimum set of tests for the constancy X-ray equipment. These tests follow the procedures set forth in the Resolution no. 64, the National Agency for Sanitary Vigilance. This work aims to show a study on dental cone beam computed tomography (CBCT), evaluating the physical parameters that influence the performance and image quality and presenting the appropriate tests to this new system. The authors analyzed the tests specific for computed tomography (CT) of the Resolution no. 64, feasibility assessment of them and if their interpretations are compatible with CBCT. Once determined if testing is feasible, compare with those presented in the manual provided by the equipment manufacturer. The CT scanner used was the Mini-Cat Tomography Scanner Xoran Technologies of KAVO. In the study it was verified that four tests could be reproduced in CBCT: noise, accuracy and uniformity in the number of CT of water and spatial resolution. Considering experimental data, the methodology and tolerance of manufacturer for the first two tests were more appropriate. For the uniformity test of the CT number, we recommend using the phantom quality control. Three new tests were suggested to be made in the quality control of the Cone Beam: linearity, artifacts and alignment of the beam. (author)

  2. HON label and DISCERN as content quality indicators of health-related websites.

    Science.gov (United States)

    Khazaal, Yasser; Chatton, Anne; Zullino, Daniele; Khan, Riaz

    2012-03-01

    Content quality indicators are warranted in order to help patients and consumers to judge the content quality of health-related on-line information. The aim of the present study is to evaluate web-based information on health topics and to assess particular content quality indicators like HON (Health on the Net) and DISCERN. The present study is based on the analysis of data issued from six previous studies which assessed with a standardized tool the general and content quality (evidence-based health information) of health-related websites. Keywords related to Social phobia, bipolar disorders, pathological gambling as well as cannabis, alcohol and cocaine addiction were entered into popular World Wide Web search engines. Websites were assessed with a standardized proforma designed to rate sites on the basis of accountability, presentation, interactivity, readability and content quality (evidence-based information). "Health on the Net" (HON) quality label, and DISCERN scale scores were used to verify their efficiency as quality indicators. Of 874 websites identified, 388 were included. Despite an observed association with higher content quality scores, the HON label fails to predict good content quality websites when used in a multiple regression. Sensibility and specificity of a DISCERN score >40 in the detection of good content quality websites were, respectively, 0.45 and 0.96. The DISCERN is a potential quality indicator with a relatively high specificity. Further developments in this domain are warranted in order to facilitate the identification of high-quality information on the web by patients.

  3. 78 FR 13365 - Prospective Grant of Exclusive License: Food Quality Indicators

    Science.gov (United States)

    2013-02-27

    ... decision can be made about quality of food and its shelf life under the storage conditions used. Since the... quality that cannot accurately estimate shelf life of food products due to unreliable storage history... Exclusive License: Food Quality Indicators AGENCY: National Institutes of Health, Public Health Service, HHS...

  4. Formalization and Computation of Diabetes Quality Indicators with Patient Data from a Chinese Hospital

    NARCIS (Netherlands)

    Liu, Haitong; ten Teije, Annette; Dentler, Kathrin; Ma, Jingdong; Zhang, Shijing; Riaño, David; Lenz, Richard; Reichert, Manfred

    2017-01-01

    Clinical quality indicators are tools to measure the quality of healthcare and can be classified into structure-related, process-related and outcome-related indicators. The objective of this study is to investigate whether Electronic Medical Record (EMR) data from a Chinese diabetes specialty

  5. OECD Health Care Quality Indicator Project. The expert panel on primary care prevention and health promotion

    NARCIS (Netherlands)

    Marshall, Martin; Klazinga, Niek; Leatherman, Sheila; Hardy, Charlie; Bergmann, Eckhard; Pisco, Luis; Mattke, Soeren; Mainz, Jan

    2006-01-01

    PURPOSE: This article describes a project undertaken as part of the Organization for Economic Co-operation and Development (OECD)'s Healthcare Quality Indicator (HCQI) Project, which aimed to develop a set of quality indicators representing the domains of primary care, prevention and health

  6. Applying Quality Indicators to Single-Case Research Designs Used in Special Education: A Systematic Review

    Science.gov (United States)

    Moeller, Jeremy D.; Dattilo, John; Rusch, Frank

    2015-01-01

    This study examined how specific guidelines and heuristics have been used to identify methodological rigor associated with single-case research designs based on quality indicators developed by Horner et al. Specifically, this article describes how literature reviews have applied Horner et al.'s quality indicators and evidence-based criteria.…

  7. An Evaluation of the Technical Adequacy of a Revised Measure of Quality Indicators of Transition

    Science.gov (United States)

    Morningstar, Mary E.; Lee, Hyunjoo; Lattin, Dana L.; Murray, Angela K.

    2016-01-01

    This study confirmed the reliability and validity of the Quality Indicators of Exemplary Transition Programs Needs Assessment-2 (QI-2). Quality transition program indicators were identified through a systematic synthesis of transition research, policies, and program evaluation measures. To verify reliability and validity of the QI-2, we…

  8. Stakeholders' perspectives on quality indicators for diabetes care: a qualitative study

    NARCIS (Netherlands)

    Markhorst, J.; Martirosyan, L.; Calsbeek, H.; Braspenning, J.C.C.

    2012-01-01

    BACKGROUND: Transparency in diabetes care requires quality indicators that are of interest to stakeholders in order to optimise their usage. Indicator development is often focused on consensus, and little is known about stakeholders' preferences for information on quality. AIM: To explore the

  9. Stakeholders' perspectives on quality indicators for diabetes care: a qualitative study.

    Science.gov (United States)

    Markhorst, Joekie; Martirosyan, Liana; Calsbeek, Hiske; Braspenning, Jozé

    2012-01-01

    Transparency in diabetes care requires quality indicators that are of interest to stakeholders in order to optimise their usage. Indicator development is often focused on consensus, and little is known about stakeholders' preferences for information on quality. To explore the preferences of consumers, providers, purchasers and policy makers for different quality domains and indicators in relation to the intended use of quality indicators. Between June and December 2009, 14 semi-structured interviews were held with stakeholders who have a decisive vote in the selection of the national indicator set for diabetes care in the Netherlands. The following subjects were explored: (1) the aims of using information on quality; (2) the interpretation of and preferences for the quality domains of safety, timeliness, effectiveness and patient-centredness in relation to the user aims; and (3) the preferences for structure, process or outcome indicators. Content analysis was used to analyse qualitative data. Stakeholders had similar and different aims according to their roles. The interpretations of quality domains varied greatly between the stakeholders. Besides differences in interpretation, their preferences were similar. Most stakeholders prioritised patient-centredness above the other domains of quality, ranked in order of priority as safety, effectiveness and timeliness, whereas purchasers also prioritised efficiency. All stakeholders preferred to use process indicators or a mix of process and outcome indicators. The preferences of the stakeholders for quality indicators seem to be neither well-refined nor congruent. The implementation of an indicator set can probably be improved if the stakeholders' definitions and preferences for quality domains become more explicit during the selection process for indicators.

  10. Potential Quality Evaluation Method for Radix Astragali Based on Sweetness Indicators

    OpenAIRE

    Ke Li; Fanrong Gao; Zhenyu Li; Xuemei Qin; Haifeng Sun; Jie Xing; Lizeng Zhang; Guanhua Du

    2015-01-01

    Sweetness is a traditional sensory indicator used to evaluate the quality of the popular Chinese herb Radix Astragali (RA). RA roots with strong sweetness are considered to be of good quality. However, neither a thorough analysis of the component(s) contributing to RA sweetness, nor a scientific investigation of the reliability of this indicator has been conducted to date. In this study, seven kinds of sweetness components were identified in RA and a quality evaluation method based on these c...

  11. Quality indicators for diagnosis and treatment of respiratory tract infections in general practice:

    DEFF Research Database (Denmark)

    Plejdrup, Malene; Bjerrum, Lars; Gahrn-Hansen, Bente

    Objective: To develop a set of quality indicators focusing on the diagnosis and treatment of respiratory tract infections in general practice.  Material and methods: A modified 2-round Delphi study was conducted from April to July 2008. A panel of 27 experts (13 countries) comprising mainly general...... practitioners, clinical microbiologists and clinical pharmacologists was invited. A list of 59 quality indicators focusing on the quality of the diagnostic process, the antibiotic treatment and the choice of antibiotics was generated. A thorough literature review was carried out to ensure that all potential...... indicators were considered. The experts were asked to rate the relevance of 59 quality indicators with regard to reducing antimicrobial resistance and improving patient health. Consensus for a quality indicator was reached if ≥ 75 % of experts scored the item ≥ 5 on a 7-point Likert scale, ranging from 1...

  12. Characterization and evaluation of an integrated quality monitoring system for online quality assurance of external beam radiation therapy.

    Science.gov (United States)

    Hoffman, David; Chung, Eunah; Hess, Clayton; Stern, Robin; Benedict, Stanley

    2017-01-01

    The aim of this work was to comprehensively evaluate a new large field ion chamber transmission detector, Integral Quality Monitor (IQM), for online external photon beam verification and quality assurance. The device is designed to be mounted on the linac accessory tray to measure and verify photon energy, field shape, gantry position, and fluence before and during patient treatment. Our institution evaluated the newly developed ion chamber's effect on photon beam fluence, response to dose, detection of photon fluence modification, and the accuracy of the integrated barometer, thermometer, and inclinometer. The detection of photon fluence modifications was performed by measuring 6 MV with fields of 10 cm × 10 cm and 1 cm × 1 cm "correct" beam, and then altering the beam modifiers to simulate minor and major delivery deviations. The type and magnitude of the deviations selected for evaluation were based on the specifications for photon output and MLC position reported in AAPM Task Group Report 142. Additionally, the change in ion chamber signal caused by a simulated IMRT delivery error is evaluated. The device attenuated 6 MV, 10 MV, and 15 MV photon beams by 5.43 ± 0.02%, 4.60 ± 0.02%, and 4.21 ± 0.03%, respectively. Photon beam profiles were altered with the IQM by < 1.5% in the nonpenumbra regions of the beams. The photon beam profile for a 1 cm × 1 cm 2 fields were unchanged by the presence of the device. The large area ion chamber measurements were reproducible on the same day with a 0.14% standard deviation and stable over 4 weeks with a 0.47% SD. The ion chamber's dose-response was linear (R 2 = 0.99999). The integrated thermometer agreed to a calibrated thermometer to within 1.0 ± 0.7°C. The integrated barometer agreed to a mercury barometer to within 2.3 ± 0.4 mmHg. The integrated inclinometer gantry angle measurement agreed with the spirit level at 0 and 180 degrees within 0.03 ± 0.01 degrees and 0.27 ± 0.03 at 90 and 270 degrees. For the

  13. [Quality indicators in the storage and dispensing process in a Hospital Pharmacy].

    Science.gov (United States)

    Rabuñal-Álvarez, M T; Calvin-Lamas, M; Feal-Cortizas, B; Martínez-López, L M; Pedreira-Vázquez, I; Martín-Herranz, M I

    2014-01-01

    To establish indicators for the evaluation of the quality of the storage and dispensing processes related to semiautomatic vertical (SAVCS) and horizontal (SAHCS) carousel systems. Descriptive observational study conducted between January-December 2012. Definition of quality indicators, a target value is established and an obtained value is calculated for 2012. Five quality indicators in the process of storage and dispensing of drugs were defined and calculated: indicator 1, error filling unidose trolleys: target (dispensing drugs to be assessed. Copyright © 2014 SECA. Published by Elsevier Espana. All rights reserved.

  14. Standards of care and quality indicators for multidisciplinary care models for psoriatic arthritis in Spain.

    Science.gov (United States)

    Gratacós, Jordi; Luelmo, Jesús; Rodríguez, Jesús; Notario, Jaume; Marco, Teresa Navío; de la Cueva, Pablo; Busquets, Manel Pujol; Font, Mercè García; Joven, Beatriz; Rivera, Raquel; Vega, Jose Luis Alvarez; Álvarez, Antonio Javier Chaves; Parera, Ricardo Sánchez; Carrascosa, Jose Carlos Ruiz; Martínez, Fernando José Rodríguez; Sánchez, José Pardo; Olmos, Carlos Feced; Pujol, Conrad; Galindez, Eva; Barrio, Silvia Pérez; Arana, Ana Urruticoechea; Hergueta, Mercedes; Coto, Pablo; Queiro, Rubén

    2018-02-07

    To define and give priority to standards of care and quality indicators of multidisciplinary care for patients with psoriatic arthritis (PsA). A systematic literature review on PsA standards of care and quality indicators was performed. An expert panel of rheumatologists and dermatologists who provide multidisciplinary care was established. In a consensus meeting group, the experts discussed and developed the standards of care and quality indicators and graded their priority, agreement and also the feasibility (only for quality indicators) following qualitative methodology and a Delphi process. Afterwards, these results were discussed with 2 focus groups, 1 with patients, another with health managers. A descriptive analysis is presented. We obtained 25 standards of care (9 of structure, 9 of process, 7 of results) and 24 quality indicators (2 of structure, 5 of process, 17 of results). Standards of care include relevant aspects in the multidisciplinary care of PsA patients like an appropriate physical infrastructure and technical equipment, the access to nursing care, labs and imaging techniques, other health professionals and treatments, or the development of care plans. Regarding quality indicators, the definition of multidisciplinary care model objectives and referral criteria, the establishment of responsibilities and coordination among professionals and the active evaluation of patients and data collection were given a high priority. Patients considered all of them as important. This set of standards of care and quality indicators for the multidisciplinary care of patients with PsA should help improve quality of care in these patients.

  15. [Evaluation of the quality of performance of general practitioners. What is the problem with primary care quality indicators in Hungary?].

    Science.gov (United States)

    Kolozsvári, László Róbert; Rurik, Imre

    2016-02-28

    The Hungarian primary care quality indicator system has been introduced in 2009, and has been continuously developed since then. The system offers extra financing for family physicians who are achieving the expected levels of indicators. There are currently 16 indicators for adult and mixed practices and 8 indicators are used in paediatric care. Authors analysed the influencing factors of the indicators other than those related to the performance of family physicians. Expectations and compliance of patients, quality of outpatient (ambulatory) care services, insufficient flow of information, inadequate primary care softwares which need to be updated could be considered as the most important factors. The level of financial motivations should also be significantly increased besides changes in the reporting system. It is recommended, that decision makers in health policy and financing have to declare clearly their expectations, and professional bodies should find the proper solution. These indicators could contribute properly to the improvement of the quality of primary care services in Hungary.

  16. Assessing Quality in Graduate Programs: An Internal Quality Indicator. AIR Forum 1981 Paper.

    Science.gov (United States)

    DiBiasio, Daniel A.; And Others

    Four approaches to measuring quality in graduate education are reviewed, and the approach used at the graduate school at Ohio State University is assessed. Four approaches found in the literature are: measuring quality by reputation, by scholarly productivity, by correlating reputation and scholarly productivity, and by multiple measures. Ohio…

  17. Evaluation of various approaches for assessing dose indicators and patient organ doses resulting from radiotherapy cone-beam CT

    Energy Technology Data Exchange (ETDEWEB)

    Rampado, Osvaldo, E-mail: orampado@cittadellasalute.to.it; Giglioli, Francesca Romana; Rossetti, Veronica; Ropolo, Roberto [Struttura Complessa Fisica Sanitaria, Azienda Ospedaliero Universitaria Città della Salute e della Scienza, Corso Bramante 88, Torino 10126 (Italy); Fiandra, Christian; Ragona, Riccardo [Radiation Oncology Department, University of Turin, Torino 10126 (Italy)

    2016-05-15

    Purpose: The aim of this study was to evaluate various approaches for assessing patient organ doses resulting from radiotherapy cone-beam CT (CBCT), by the use of thermoluminescent dosimeter (TLD) measurements in anthropomorphic phantoms, a Monte Carlo based dose calculation software, and different dose indicators as presently defined. Methods: Dose evaluations were performed on a CBCT Elekta XVI (Elekta, Crawley, UK) for different protocols and anatomical regions. The first part of the study focuses on using PCXMC software (PCXMC 2.0, STUK, Helsinki, Finland) for calculating organ doses, adapting the input parameters to simulate the exposure geometry, and beam dose distribution in an appropriate way. The calculated doses were compared to readouts of TLDs placed in an anthropomorphic Rando phantom. After this validation, the software was used for analyzing organ dose variability associated with patients’ differences in size and gender. At the same time, various dose indicators were evaluated: kerma area product (KAP), cumulative air-kerma at the isocenter (K{sub air}), cone-beam dose index, and central cumulative dose. The latter was evaluated in a single phantom and in a stack of three adjacent computed tomography dose index phantoms. Based on the different dose indicators, a set of coefficients was calculated to estimate organ doses for a range of patient morphologies, using their equivalent diameters. Results: Maximum organ doses were about 1 mGy for head and neck and 25 mGy for chest and pelvis protocols. The differences between PCXMC and TLDs doses were generally below 10% for organs within the field of view and approximately 15% for organs at the boundaries of the radiation beam. When considering patient size and gender variability, differences in organ doses up to 40% were observed especially in the pelvic region; for the organs in the thorax, the maximum differences ranged between 20% and 30%. Phantom dose indexes provided better correlation with organ

  18. Concordance between nurse-reported quality of care and quality of care as publicly reported by nurse-sensitive indicators

    NARCIS (Netherlands)

    Stalpers, Dewi; Kieft, Renate A M M; Van Der Linden, Dimitri; Kaljouw, Marian J.; Schuurmans, Marieke J.

    2016-01-01

    Background: Nurse-sensitive indicators and nurses' satisfaction with the quality of care are two commonly used ways to measure quality of nursing care. However, little is known about the relationship between these kinds of measures. This study aimed to examine concordance between nurse-sensitive

  19. How to Assist Intensive Care Units in Improving Healthcare Quality. Development of Actionable Quality Indicators on Blood use

    NARCIS (Netherlands)

    Roos-Blom, Marie-José; Dongelmans, Dave; Arbous, M. Sesmu; de Jonge, Evert; de Keizer, Nicolette

    2015-01-01

    Previously developed quality indicators (QIs) for the intensive care did not give clues for quality improvement. We will improve this by developing new QIs that are actionable, reliable, valid and easy to register. Using a modified RAND technique we developed in three rounds new QIs for blood use at

  20. Concordance between nurse-reported quality of care and quality of care as publicly reported by nurse-sensitive indicators

    NARCIS (Netherlands)

    D. Stalpers (Dewi); R.A.M.M. Kieft (Renate A. M. M.); D. van der Linden (Dimitri); M.J. Kaljouw (Marian J.); M.J. Schuurmans (Marieke )

    2016-01-01

    textabstractBackground: Nurse-sensitive indicators and nurses' satisfaction with the quality of care are two commonly used ways to measure quality of nursing care. However, little is known about the relationship between these kinds of measures. This study aimed to examine concordance between

  1. Concordance between nurse-reported quality of care and quality of care as publicly reported by nurse-sensitive indicators

    NARCIS (Netherlands)

    Dewi Stalpers; Prof. Dr. Marieke J. Schuurmans; Marian J. Kaljouw; Renate A.M.M. Kieft; Dimitri van der Linden

    2016-01-01

    Background: Nurse-sensitive indicators and nurses’ satisfaction with the quality of care are two commonly used ways to measure quality of nursing care. However, little is known about the relationship between these kinds of measures. This study aimed to examine concordance between nurse-sensitive

  2. Prioritizing of performance indicators of quality - effectiveness areas of general hospitals using Analytic Hierarchy Process (AHP

    Directory of Open Access Journals (Sweden)

    hosein Jabbari Beyrami

    2014-06-01

    Full Text Available Background: Quality of health care includes some degree of services provided to individuals and communities to increase the likelihood of desired results and are updated in accordance with professional knowledge. To assess the quality of services provided in hospitals, indicators and performance standards are needed to be identified, because these indicators are the structure of the hospital evaluation. This study aimed to determine the performance indicators in general- public hospitals in area of quality and effectiveness and prioritization of these indicators. Materials and Methods: This descriptive-qualitative and practical research was done through a systematic review of literature and data were obtained from the hospital authorities. In order to prioritize public hospital performance indicators, Analytic Hierarchy Process (AHP was used and the results were analyzed by the Expert Choice software. Results: In the field of quality and effectiveness, 73 performance indicators were considering at various texts. Indicators such as the rate of hospital infections (100%, the incidence of hospital events (72%, Net hospital mortality(63%, Percentage of patients' satisfaction(53% selected as key performance indicators. Conclusion: Performance indicators in the field of quality and effectiveness has important place in health system and hospital organization. By evaluating the quality of services in health centers, the problems and shortcomings can be seen, and consequently analyzing information can lead to a try to reduce them.

  3. Combining Archetypes, Ontologies and Formalization Enables Automated Computation of Quality Indicators.

    Science.gov (United States)

    Legaz-García, María Del Carmen; Dentler, Kathrin; Fernández-Breis, Jesualdo Tomás; Cornet, Ronald

    2017-01-01

    ArchMS is a framework that represents clinical information and knowledge using ontologies in OWL, which facilitates semantic interoperability and thereby the exploitation and secondary use of clinical data. However, it does not yet support the automated assessment of quality of care. CLIF is a stepwise method to formalize quality indicators. The method has been implemented in the CLIF tool which supports its users in generating computable queries based on a patient data model which can be based on archetypes. To enable the automated computation of quality indicators using ontologies and archetypes, we tested whether ArchMS and the CLIF tool can be integrated. We successfully automated the process of generating SPARQL queries from quality indicators that have been formalized with CLIF and integrated them into ArchMS. Hence, ontologies and archetypes can be combined for the execution of formalized quality indicators.

  4. Canadian Association of Gastroenterology Consensus Guidelines on Safety and Quality Indicators in Endoscopy

    Directory of Open Access Journals (Sweden)

    David Armstrong

    2012-01-01

    Full Text Available Several organizations worldwide have developed procedure-based guidelines and/or position statements regarding various aspects of quality and safety indicators, and credentialing for endoscopy. Although important, they do not specifically address patient needs or provide a framework for their adoption in the context of endoscopy services. The consensus guidelines reported in this article, however, aimed to identify processes and indicators relevant to the provision of high-quality endoscopy services that will support ongoing quality improvement across many jurisdictions, specifically in the areas of ethics, facility standards and policies, quality assurance, training and education, reporting standards and patient perceptions.

  5. Soft X-ray generation via inverse compton scattering between high quality electron beam and high power laser

    International Nuclear Information System (INIS)

    Masakazu Washio; Kazuyuki Sakaue; Yoshimasa Hama; Yoshio Kamiya; Tomoko Gowa; Akihiko Masuda; Aki Murata; Ryo Moriyama; Shigeru Kashiwagi; Junji Urakawa

    2007-01-01

    High quality beam generation project based on High-Tech Research Center Project, which has been approved by Ministry of Education, Culture, Sports, Science and Technology in 1999, has been conducted by advance research institute for science and engineering, Waseda University. In the project, laser photo-cathode RF-gun has been selected for the high quality electron beam source. RF cavities with low dark current, which were made by diamond turning technique, have been successfully manufactured. The low emittance electron beam was realized by choosing the modified laser injection technique. The obtained normalized emmitance was about 3 m.mrad at 100 pC of electron charge. The soft x-ray beam generation with the energy of 370 eV, which is in the energy region of so-called water window, by inverse Compton scattering has been performed by the collision between IR laser and the low emmitance electron beams. (Author)

  6. Electron beam irradiation: a novel technology to enhance the quality of soybean seeds

    International Nuclear Information System (INIS)

    Bhalla, Shashi; Srinivasan, K.; Singh, Subadas; Thakur, Manju; Sharma, S.K.; Pramod, R.; Dwivedi, J.; Bapna, S.C.

    2010-01-01

    Soybean seeds, rich in protein and oil, maintain their germinability only for short durations under ambient conditions. Loss of viability of stored seeds often hampers soybean production in harsh environments worldwide. Physiological factors favored by high temperature and high moisture content accelerate the seed deterioration in the tropics. Several chemical and physical treatments are being used to enhance quality. Irradiation is a novel technology for food preservation and is gaining importance all over the world. Low doses of irradiation bring about improvement in quality of food/seeds, which can be beneficial in several ways. Electron Beam (EB) irradiation is a new approach in this area. The objective of present study was to investigate the effect of EB irradiation in enhancing the quality of low vigour soybean seeds

  7. Indications for total cutaneous electron beam radiation therapy of mycosis fungoides

    International Nuclear Information System (INIS)

    Le Bourgeois, J.P.; Haddad, E.; Marinello, G.; Marin, L.; Mazeron, J.J.; Ganem, G.

    1987-01-01

    From 1977 to 1984, we treated 34 patients with mycosis fungoides and 9 patients with B cutaneous lymphomas. Eighteen patients with mycosis fungoides were treated with total skin electron irradiation (TSEI) and had a minimum follow-up of 15 months (range 15 months to 7 years). The lowest electron energy of the linear accelerator was 8 MeV therefore we placed a plexiglas screen between the patient and the machine; the resulting electron energy was 4 MeV. The total dose was 30 Gy delivered in 12 fractions over 40 days. There were 8 males and 10 females. The median age was 48 years (ranging from 13 to 78 years). All patients were staged as follows: Stage A = superficial lesions covering less than 50% of the body surface; Stage B = superficial lesions covering more than 50% of the body surface; Stage C = tumors involving the skin, lymph nodes and/or visceral organs. Five patients with Stage A (5/5) and 5 patients with Stage B (5/5) had a complete remission, 1 stage A patient relapsed 6 months after completion of treatment. All the Stage B patients recurred between 3 and 15 months. The recurrences were localized to the skin and were well controlled with topical nitrogen mustard or puvatherapy. Among the Stage C patients, 3 did not respond to treatment and died of their disease; the remaining 5 patients achieved complete remission but they all relapsed from 2 to 9 months following completion of treatment. The median follow-up was 32 months and the average time for relapse was 6.5 months. All relapses except one (15 months) occurred within the first year. We feel that total skin electron irradiation is indicated in Stage A and B patients. However, we feel Stage C patients should receive TSEI for palliative purposes only

  8. LHCB: A LHCb-VELO module as beam quality monitor for proton therapy beam at the Clatterbridge Centre for Oncology

    CERN Multimedia

    Casse, G; Patel, G D; Smith, N A; Kacperek, A; Marsland, B

    2010-01-01

    The progress in detector technology, driven by the needs of particle tracking and vertexing in the present LHC and its upgrade (sLHC), has led to the design of silicon sensors with low mass, high granularity, high speed and unprecedented radiation hardness. The sensors designed for such a harsh environment can be profitably used for instrumenting the control systems of therapeutic hadron beams. The high granularity and readout clock speed are well suited for monitoring continuous beam currents. The low mass allows reduced interference with the beam whilst monitoring its profile with high precision. The high resolution and sensitivity to minimum ionising particles allows monitoring of the beam spot position by measurement of the halo in real time, without any interference with the beam spot used in therapy.

  9. Evaluation of Skin Dose and Image Quality on Cone Beam Computed Tomography

    International Nuclear Information System (INIS)

    Ahn, Jong Ho; Hong, Chae Seon; Kim, Jin Man; Jang, Jun Young

    2008-01-01

    Cone-beam CT using linear accelerator attached to on-board imager is a image guided therapy equipment. Because it is to check the patient's set-up error, correction, organ and target movement. But imaging dose should be cause of the secondary cancer when taking a image. The aim of this study is investigation of appropriate cone beam CT scan mode to compare and estimate the image quality and skin dose. Measurement by Thermoluminescence dosimeter (TLD-100, Harshaw) with using the Rando phantom are placed on each eight sites in separately H and N, thoracic, abdominal section. each 4 methods of scan modes of are measured the for skin dose in three time. Subsequently, obtained average value. Following image quality QA protocol of equipment manufacturers using the catphan 504 phantom, image quality of each scan mode is compared and analyzed. The results of the measured skin dose are described in here. The skin dose of Head and Neck are measured mode A: 8.96 cGy, mode B: 4.59 cGy, mode C: 3.46 cGy mode D: 1.76 cGy and thoracic mode A: 9.42 cGy, mode B: 4.58 cGy, mode C: 3.65 cGy, mode D: 1.85 cGy, and abdominal mode A: 9.97 cGy, mode B: 5.12 cGy, mode C: 4.03 cGy, mode D: 2.21 cGy. Approximately, dose of mode B are reduced 50%, mode C are reduced 60%, mode D are reduced 80% a point of reference dose of mode A. the results of analyzed HU reproducibility, low contrast resolution, spatial resolution (high contrast resolution), HU uniformity in evaluation item of image quality are within the tolerance value by recommended equipment manufacturer in all scan mode. Maintaining the image quality as well as reducing the image dose are very important in cone beam CT. In the result of this study, we are considered when to take mode A when interested in soft tissue. And we are considered to take mode D when interested in bone scan and we are considered to take mode B, C when standard scan. Increasing secondary cancer risk due to cone beam CT scan should be reduced by low m

  10. Quality indicators for treatment of respiratory tract infections? An assessment by Danish general practitioners

    DEFF Research Database (Denmark)

    Hansen, Malene Plejdrup; Bjerrum, Lars; Gahrn-Hansen, Bente

    2013-01-01

    Background: In 2008, a set of 41 quality indicators for antibiotic treatment of respiratory tract infections (RTIs) in general practice were developed in an international setting as part of the European project HAPPY AUDIT. Objectives: To investigate Danish general practitioners' (GPs') assessment...... of a set of internationally developed quality indicators and to explore if there is an association between the GPs' assessment of the indicators and their practice characteristics as well as their antibiotic prescription pattern. Methods: A total of 102 Danish GPs were invited to assess the 41 quality...

  11. WATER QUALITY ANALYSIS OF LOTIC ECOSYSTEMS FROM UPPER MUREŞ RIVER CATCHMENT AREA USING DIFFERENT BIOTIC INDICES

    Directory of Open Access Journals (Sweden)

    Milca PETROVICI

    2012-01-01

    Full Text Available Present paper approach the issue of assessing the water quality of tributaries located in the upper basin of the river Mureş, taking into account changes in the value of biotic indices. In this sense, have been selected the next five biotic indices: Ephemeroptera Plecoptera Trichoptera index (EPT, Total Invertebrates index (T, Chironomidae index (Ch, EPT / Total invertebrates index (EPT / T, EPT / Chironomidae index (EPT / Ch and % Chironomidae index (% Chironomidae. Considering all these indices, it was found existence of a medium to best quality water in Mureş tributaries from Harghita Mountains and a good quality water which comes from the Maramureş Mountains and Transylvania Plateau.

  12. An Overview of Key Indicators and Evaluation Tools for Assessing Housing Quality: A Literature Review

    Science.gov (United States)

    Sinha, Rajan Chandra; Sarkar, Satyaki; Mandal, Nikhil Ranjan

    2017-09-01

    The issue of the housing quality has been addressed for various stakeholders at different levels. There exist varied opinion about its measurability and possible applications. Thus the study is carried out to have an insight into the concept of housing quality and its relevance in the changing demographics, technological, socio-economic and socio-cultural conditions. This study attempts to summarize the literature that addresses past research concerned with factors related to housing quality, its measurement methodology and critically examines the broad key indicators identified to have impact upon enhancing the housing quality. This work discusses the recent techniques which are extensively used for analysis of housing quality.

  13. Image quality of two different mobile cone beam computed tomographs for maxillofacial surgery.

    Science.gov (United States)

    Seeberger, Robin; Buchgeister, Markus; Seethaler, Andreas C; Shiozawa, Thomas; Hoffmann, Juergen

    2012-12-01

    We evaluated two mobile cone beam computed tomographs (mCBCT) comparing image quality with respect to radiation dosage. Image quality was analyzed by using different scanning modes. The skulls of three human cadavers were scanned by use of conventional Computed Tomography (CT) as well as with two mobile cone beam computed tomographs (Siemens Arcadis Orbic 3D and Ziehm Vision Vario 3D). Six different acquisition modes with different radiation dosages were used. The axial views of all scans were evaluated by five medical doctors regarding image quality by identifying predefined anatomical structures of the skull. A five-point ranking scale was used. The inter-rater reliability was statistically depicted by Cohen's Kappa coefficient. A Wilcoxon signed rank test was used to evaluate the rater's results. For evaluating the signal-to-noise ratio (SNR) a Catphan 600 reference body with two different inlays was used. Comparing the mCBCTs, the image quality of the Siemens Arcadis Orbic 3D in high-dosage mode received the best score (median: 2.27). The inter-rater reliability was fair (Kappa=-0.030 to 0.328). The Wilcoxon test showed significant (p<0.05) different median rating values in 18 out of 21 imaging modes. The SNR was higher (better) in the high-dosage modes. Intra-operative 3D imaging by using mCBCT for maxillofacial surgery in low-dose mode acquisition is adequate in terms of signal-to-noise ratio and image quality. The image quality does not correlate in a linear manner with a higher radiation dosage. Surgeons using this technique should gather their own experience with the different acquisition modes. Copyright © 2012 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  14. Study of the selection of indicator parameters in marine water quality evaluation and the evaluation methodology

    Science.gov (United States)

    Zhang, Ying; Pan, Delu; Wang, Difeng; Fu, Dongyang

    2014-10-01

    In order to obtain the indicator types which must be introduced in marine water quality evaluation as well as the suitable evaluation methodology, GB3097-1997 National Marine Water Quality Standards is, in the first place, analyzed to establish a hypothetical sample which is consisting of 2000 stances, each stance containing the information of 21 indicators. And then a stepwise discriminant method is utilized to filter the 21 indicators in accordance with their water quality classification discriminant abilities. And finally, 6 indicators with significant discriminant ability, biochemical oxygen demand(BOD5), oil type(Oil), total phosphorus(P), cadmium(Cd), cyanide(HH) and chemical oxygen demand(COD), are selected and the water quality evaluation chart of the corresponding six indicators is also established. Theoretically, the water quality indicator types and the suitable evaluation methodology, which must be introduced when the water quality evaluation is done in all the waters under the jurisdiction of China, are discussed in this paper, providing theoretical basis for the subsequent marine water quality evaluation based on field observation.

  15. Dosimetry quality audit of high energy photon beams in greek radiotherapy centers

    International Nuclear Information System (INIS)

    Hourdakis, Constantine J.; Boziari, A.

    2008-01-01

    Background and purpose: Dosimetry quality audits and intercomparisons in radiotherapy centers is a useful tool in order to enhance the confidence for an accurate therapy and to explore and dissolve discrepancies in dose delivery. This is the first national comprehensive study that has been carried out in Greece. During 2002 - 2006 the Greek Atomic Energy Commission performed a dosimetry quality audit of high energy external photon beams in all (23) Greek radiotherapy centers, where 31 linacs and 13 Co-60 teletherapy units were assessed in terms of their mechanical performance characteristics and relative and absolute dosimetry. Materials and Methods: The quality audit in dosimetry of external photon beams took place by means of on-site visits, where certain parameters of the photon beams were measured, calculated and assessed according to a specific protocol and the IAEA TRS 398 dosimetry code of practice. In each radiotherapy unit (Linac or Co-60), certain functional parameters were measured and the results were compared to tolerance values and limits. Doses in water under reference and non reference conditions were measured and compared to the stated values. Also, the treatment planning systems (TPS) were evaluated with respect to irradiation time calculations. Results: The results of the mechanical tests, dosimetry measurements and TPS evaluation have been presented in this work and discussed in detail. This study showed that Co-60 units had worse performance mechanical characteristics than linacs. 28% of all irradiation units (23% of linacs and 42% of Co-60 units) exceeded the acceptance limit at least in one mechanical parameter. Dosimetry accuracy was much worse in Co60 units than in linacs. 61% of the Co60 units exhibited deviations outside ±3% and 31% outside ±5%. The relevant percentages for the linacs were 24% and 7% respectively. The results were grouped for each hospital and the sources of errors (functional and human) have been investigated and

  16. Dosimetry quality audit of high energy photon beams in greek radiotherapy centers.

    Science.gov (United States)

    Hourdakis, Constantine J; Boziari, A

    2008-04-01

    Dosimetry quality audits and intercomparisons in radiotherapy centers is a useful tool in order to enhance the confidence for an accurate therapy and to explore and dissolve discrepancies in dose delivery. This is the first national comprehensive study that has been carried out in Greece. During 2002--2006 the Greek Atomic Energy Commission performed a dosimetry quality audit of high energy external photon beams in all (23) Greek radiotherapy centers, where 31 linacs and 13 Co-60 teletherapy units were assessed in terms of their mechanical performance characteristics and relative and absolute dosimetry. The quality audit in dosimetry of external photon beams took place by means of on-site visits, where certain parameters of the photon beams were measured, calculated and assessed according to a specific protocol and the IAEA TRS 398 dosimetry code of practice. In each radiotherapy unit (Linac or Co-60), certain functional parameters were measured and the results were compared to tolerance values and limits. Doses in water under reference and non reference conditions were measured and compared to the stated values. Also, the treatment planning systems (TPS) were evaluated with respect to irradiation time calculations. The results of the mechanical tests, dosimetry measurements and TPS evaluation have been presented in this work and discussed in detail. This study showed that Co-60 units had worse performance mechanical characteristics than linacs. 28% of all irradiation units (23% of linacs and 42% of Co-60 units) exceeded the acceptance limit at least in one mechanical parameter. Dosimetry accuracy was much worse in Co60 units than in linacs. 61% of the Co60 units exhibited deviations outside +/-3% and 31% outside +/-5%. The relevant percentages for the linacs were 24% and 7% respectively. The results were grouped for each hospital and the sources of errors (functional and human) have been investigated and discussed in details. This quality audit proved to be a

  17. Linking clinical quality indicators to research evidence - a case study in asthma management for children.

    Science.gov (United States)

    Choong, Miew Keen; Tsafnat, Guy; Hibbert, Peter; Runciman, William B; Coiera, Enrico

    2017-07-21

    Clinical quality indicators are used to monitor the performance of healthcare services and should wherever possible be based on research evidence. Little is known however about the extent to which indicators in common use are based on research. The objective of this study is to measure the extent to which clinical quality indicators used in asthma management in children with outcome measurements can be linked to results in randomised controlled clinical trial (RCT) reports. This work is part of a broader research program to trial methods that improve the efficiency and accuracy of indicator development. National-level indicators for asthma management in children were extracted from the National Quality Measures Clearinghouse database and the National Institute for Health and Care Excellence quality standards by two independent appraisers. Outcome measures were extracted from all published English language RCT reports for asthma management in children below the age of 12 published between 2005 and 2014. The two sets were then linked by manually mapping both to a common set of Unified Medical Language System (UMLS) concepts. The analysis identified 39 indicators and 562 full text RCTs dealing with asthma management in children. About 95% (37/39) of the indicators could be linked to RCT outcome measures. It is possible to identify relevant RCT reports for the majority of indicators used to assess the quality of asthma management in childhood. The methods reported here could be automated to more generally support assessment of candidate indicators against the research evidence.

  18. Pork loin quality is not indicative of fresh belly or fresh and cured ham quality.

    Science.gov (United States)

    Arkfeld, E K; Wilson, K B; Overholt, M F; Harsh, B N; Lowell, J E; Hogan, E K; Klehm, B J; Bohrer, B M; Mohrhauser, D A; King, D A; Wheeler, T L; Dilger, A C; Shackelford, S D; Boler, D D

    2016-12-01

    The objective was to characterize the relationship between fresh loin quality with fresh belly or fresh and cured ham quality. Pigs raised in 8 barns representing 2 seasons [cold ( = 4,290) and hot ( = 3,394)] and 2 production focuses [lean ( = 3,627) and quality ( = 4,057)] were used. Carcass characteristics and other meat quality data were collected on 7,684 carcasses. All of the carcasses were evaluated for HCW, LM depth, tenth rib fat depth, leg (ham primal) weight, instrumental color on the gluteus medius and gluteus profundus of the ham face, and subjective loin quality. Instrumental loin color and ultimate pH (≥ 22 h postmortem) were collected on the ventral side of loins along with dimensions and firmness scores of fresh bellies from 50% of the carcasses. Ten percent of the boneless loins and fresh hams were evaluated for slice shear force (SSF) or cured ham characteristics. Correlation coefficients between traits were computed using the CORR procedure of SAS and considered significantly different from 0 at ≤ 0.05. Temperature decline, beginning at 31 min postmortem and concluding at 22 h postmortem, for the longissimus dorsi and semimembranosus muscles were evaluated on 10% of the carcasses. Ultimate loin pH was correlated with dimensional belly characteristics ( ≥ |0.07|; ham instrumental color ( ≥ |0.03|; ≤ 0.05), and semimembranosus ultimate pH ( = 0.33; hams. Instrumental L*on the ventral surface of the loin was related to L* on both muscles of the ham face ( ≤ 0.0001). Even though significant relationships between the loin, belly, and ham were detected, the variability in belly and ham quality explained by variability in loin quality was poor (≤ 22.09%). Compositional differences between the loin and belly may have contributed to those poor relationships. Additionally, differences in temperature declines during chilling between the loin and ham likely contributed to the weak nature of relationships. Equilibration of longissimus dorsi

  19. [Obsessive compulsive disorder and the internet. An evaluation of Dutch-language websites and quality indicators].

    Science.gov (United States)

    Serdobbel, Y; Pieters, G; Joos, S

    2006-01-01

    The Internet is an important source of information about health matters. The quality of the information about Obsessive Compulsive Disorder (OCD) has not been investigated. Possible indicators of quality are the DISCERN rating tool, Google PageRank and cooperation from health care professionals. To investigate the quality of the information given on Dutch-language websites relating to OCD and to determine whether the quality of the contents is correlated with site characteristics, scores on DISCERN and Google PageRank. We selected 27 Dutch-language websites via Google and Ixquick and investigated the correlation between the quality of the contents measured by 4 parameters and the presence of incorrect information, site characteristics, the DISCERN score and Google PageRank. The quality of the information was generally poor. The only investigated site characteristic that was found to be associated with basic criteria relating to symptoms and diagnosis was the size of the site. The DISCERN score was significantly correlated with the quality of the information. The occurrence of incorrect information was independent of the quality of the content, site characteristics, Google PageRank and DISCERN scores. The quality of Dutch-language websites on the subject of OCD is inadequate. Site characteristics and Google PageRank are not good predictors of the quality of information. The DISCERN rating tool is a potentially valuable indicator of content quality with regard to treatment options.

  20. Serengeti real estate: density vs. fitness-based indicators of lion habitat quality.

    Science.gov (United States)

    Mosser, Anna; Fryxell, John M; Eberly, Lynn; Packer, Craig

    2009-10-01

    Habitat quality is typically inferred by assuming a direct relationship between consumer density and resource abundance, although it has been suggested that consumer fitness may be a more accurate measure of habitat quality. We examined density vs. fitness-based measures of habitat quality for lions in the Serengeti National Park, Tanzania. A 40-year average of female reproductive success (yearling cubs per female) was best explained by proximity to river confluences, whereas patterns of productivity (yearling cubs per km(2)) and adult female density (individuals per km(2)) were associated with more general measures of habitat quality and areas of shelter in poor habitat. This suggests that density may not accurately distinguish between high-quality 'source' areas and low-quality sites that merely provide refuges for effectively non-reproductive individuals. Our results indicate that density may be a misleading indicator of real estate value, particularly for populations that do not conform to an ideal free distribution.

  1. Beam quality evaluation of 20/400 µm large-mode-area fiber based on mode decomposition and reconstruction

    Science.gov (United States)

    Bai, Gang; Chen, Xiaolong; Yang, Yifeng; Zheng, Ye; Zhao, Xiang; Liu, Kai; Zhao, Chun; Qi, Yunfeng; He, Bing; Zhou, Jun

    2018-02-01

    We implement a fast beam quality factor evaluation of a large-mode-area 20/400 µm fiber based on mode decomposition and reconstruction. Each transverse mode power weight factor and relative phase difference at the fiber output facet are estimated by the stochastic parallel gradient descent algorithm based simply on the instantaneous acquired charge coupled device near-field beam profile. The beam quality factor M 2 in two orthogonal directions can be analyzed in consideration of the complex amplitude of each transmission mode. The performance of our method is verified by applying it to the beam quality measurement of a 217.4 W high-power fiber laser. The calculated M 2 in two directions are 1.25 and 1.18, respectively, which is in good agreement with the measured results of 1.29 and 1.24. The proposed method could be helpful for beam quality evaluation of high-power fiber lasers and amplifiers, where the rapid change of the beam quality factor is difficult to detect due to mode instability.

  2. Cone-beam CT hepatic arteriography in chemoembolization for hepatocellular carcinoma: angiographic image quality and its determining factors.

    Science.gov (United States)

    Lee, In Joon; Chung, Jin Wook; Yin, Yong Hu; Kim, Hyo-Cheol; Kim, Young Il; Jae, Hwan Jun; Park, Jae Hyung

    2014-09-01

    To analyze image quality and the factors that determine it for cone-beam computed tomography (CT) hepatic arteriography in chemoembolization for hepatocellular carcinoma (HCC). From September 2009-December 2010, 399 consecutive patients referred for chemoembolization of HCC were scheduled for cone-beam CT scan. There were 12 patients (3%) excluded because of difficulty with breath-hold. Of the 387 patients who underwent cone-beam CT hepatic arteriography, 100 patients were ultimately included in the study according to inclusion criteria. Maximum intensity projection images were scored for image quality of each segmental hepatic artery. Potential determining factors for image quality were diaphragmatic motion, portal vein enhancement, and hepatic artery-to-parenchyma enhancement ratio. The flow rate of contrast media, x-ray delay, and location of the catheter tip were also evaluated. It was possible to trace at least subsegmental hepatic arteries in 625 of 700 segments (89.3%) on cone-beam CT hepatic arteriography. Diaphragmatic motion, prominent portal vein enhancement, and low hepatic artery-to-parenchyma enhancement ratio worsened image quality (P cone-beam CT hepatic arteriography images was good enough to trace subsegmental hepatic arteries at a minimum. Respiratory and cardiac motion, portal vein enhancement, and hepatic artery-to-parenchyma enhancement ratio significantly affected the image quality of cone-beam CT hepatic arteriography. Copyright © 2014 SIR. Published by Elsevier Inc. All rights reserved.

  3. Canadian Association of Gastroenterology consensus guidelines on safety and quality indicators in endoscopy.

    Science.gov (United States)

    Armstrong, David; Barkun, Alan; Bridges, Ron; Carter, Rose; de Gara, Chris; Dube, Catherine; Enns, Robert; Hollingworth, Roger; Macintosh, Donald; Borgaonkar, Mark; Forget, Sylviane; Leontiadis, Grigorios; Meddings, Jonathan; Cotton, Peter; Kuipers, Ernst J

    2012-01-01

    Increasing use of gastrointestinal endoscopy, particularly for colorectal cancer screening, and increasing emphasis on health care quality, highlight the need for clearly defined, evidence-based processes to support quality improvement in endoscopy. To identify processes and indicators of quality and safety relevant to high-quality endoscopy service delivery. A multidisciplinary group of 35 voting participants developed recommendation statements and performance indicators. Systematic literature searches generated 50 initial statements that were revised iteratively following a modified Delphi approach using a web-based evaluation and voting tool. Statement development and evidence evaluation followed the AGREE (Appraisal of Guidelines, REsearch and Evaluation) and GRADE (Grading of Recommendations, Assessment, Development and Evaluation) guidelines. At the consensus conference, participants voted anonymously on all statements using a 6-point scale. Subsequent web-based voting evaluated recommendations for specific, individual quality indicators, safety indicators and mandatory endoscopy reporting fields. Consensus was defined a priori as agreement by 80% of participants. Consensus was reached on 23 recommendation statements addressing the following: ethics (statement 1: agreement 100%), facility standards and policies (statements 2 to 9: 90% to 100%), quality assurance (statements 10 to 13: 94% to 100%), training, education, competency and privileges (statements 14 to 19: 97% to 100%), endoscopy reporting standards (statements 20 and 21: 97% to 100%) and patient perceptions (statements 22 and 23: 100%). Additionally, 18 quality indicators (agreement 83% to 100%), 20 safety indicators (agreement 77% to 100%) and 23 recommended endoscopy-reporting elements (agreement 91% to 100%) were identified. The consensus process identified a clear need for high-quality clinical and outcomes research to support quality improvement in the delivery of endoscopy services. The

  4. Comparative assessment of subjective image quality of cross-sectional cone-beam computed tomography scans

    International Nuclear Information System (INIS)

    Kamburoglu, K.; Murat, S.; Kolsuz, E.; Kurt, H.; Paksoy, C.; Yueksel, S.

    2011-01-01

    Since the introduction of cone-beam computed tomography (CBCT), several novel systems with different technical specifications and settings have become commercially available. Therefore, it is essential to evaluate CBCT systems for differences in the subjective quality of images obtained for various dental procedures. We evaluated the subjective image quality of cross-sectional scans obtained from various CBCT systems. Images of three cadaver mandibles were obtained from four different CBCT units: Veraviewepocs 3D 40 x 40 mm field of view (FOV) (voxel size: 0.125 x 0.125 x 0.125 mm), Iluma, low-resolution (voxel size: 0.3 x 0.3 x 0.3 mm), Kodak, 50 x 3.7 cm field of view (FOV) (voxel size: 0.076 x 0.076 x 0.076 mm), and Vatech 12 x 8.5 cm FOV (voxel size: 0.160 x 0.160 x 0.160 mm). We assessed subjective image quality and the visibility of 10 specific features, namely, caries, amalgam restoration, final implant drill, root canal filling, metal crown, mandibular canal, mental foramen, tooth (periodontal ligament space and lamina dura), trabecular pattern, and soft tissue. Images were viewed and scored by five calibrated observers, and image quality was ranked from best to worst. The Veraviewepocs 3D had the highest quality images for most of the assessed features, whereas the Iluma low-resolution scans were rated as the lowest quality images. (author)

  5. Development of Indicators to Assess Quality of Care for Prostate Cancer.

    Science.gov (United States)

    Nag, Nupur; Millar, Jeremy; Davis, Ian D; Costello, Shaun; Duthie, James B; Mark, Stephen; Delprado, Warick; Smith, David; Pryor, David; Galvin, David; Sullivan, Frank; Murphy, Áine C; Roder, David; Elsaleh, Hany; Currow, David; White, Craig; Skala, Marketa; Moretti, Kim L; Walker, Tony; De Ieso, Paolo; Brooks, Andrew; Heathcote, Peter; Frydenberg, Mark; Thavaseelan, Jeffery; Evans, Sue M

    2016-02-20

    The development, monitoring, and reporting of indicator measures that describe standard of care provide the gold standard for assessing quality of care and patient outcomes. Although indicator measures have been reported, little evidence of their use in measuring and benchmarking performance is available. A standard set, defining numerator, denominator, and risk adjustments, will enable global benchmarking of quality of care. To develop a set of indicators to enable assessment and reporting of quality of care for men with localised prostate cancer (PCa). Candidate indicators were identified from the literature. An international panel was invited to participate in a modified Delphi process. Teleconferences were held before and after each voting round to provide instruction and to review results. Panellists were asked to rate each proposed indicator on a Likert scale of 1-9 in a two-round iterative process. Calculations required to report on the endorsed indicators were evaluated and modified to reflect the data capture of the Prostate Cancer Outcomes Registry-Australia and New Zealand (PCOR-ANZ). A total of 97 candidate indicators were identified, of which 12 were endorsed. The set includes indicators covering pre-, intra-, and post-treatment of PCa care, within the limits of the data captured by PCOR-ANZ. The 12 endorsed quality measures enable international benchmarking on the quality of care of men with localised PCa. Reporting on these indicators enhances safety and efficacy of treatment, reduces variation in care, and can improve patient outcomes. PCa has the highest incidence of all cancers in men. Early diagnosis and relatively high survival rates mean issues of quality of care and best possible health outcomes for patients are important. This paper identifies 12 important measurable quality indicators in PCa care. Copyright © 2016 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  6. Prioritizing performance measurement for emergency department care: consensus on evidence-based quality of care indicators.

    Science.gov (United States)

    Schull, Michael J; Guttmann, Astrid; Leaver, Chad A; Vermeulen, Marian; Hatcher, Caroline M; Rowe, Brian H; Zwarenstein, Merrick; Anderson, Geoffrey M

    2011-09-01

    The evaluation of emergency department (ED) quality of care is hampered by the absence of consensus on appropriate measures. We sought to develop a consensus on a prioritized and parsimonious set of evidence-based quality of care indicators for EDs. The process was led by a nationally representative steering committee and expert panel (representatives from hospital administration, emergency medicine, health information, government, and provincial quality councils). A comprehensive review of the scientific literature was conducted to identify candidate indicators. The expert panel reviewed candidate indicators in a modified Delphi panel process using electronic surveys; final decisions on inclusion of indicators were made by the steering committee in a guided nominal group process with facilitated discussion. Indicators in the final set were ranked based on their priority for measurement. A gap analysis identified areas where future indicator development is needed. A feasibility study of measuring the final set of indicators using current Canadian administrative databases was conducted. A total of 170 candidate indicators were generated from the literature; these were assessed based on scientific soundness and their relevance or importance. Using predefined scoring criteria in two rounds of surveys, indicators were coded as "retained" (53), "discarded" (78), or "borderline" (39). A final set of 48 retained indicators was selected and grouped in nine categories (patient satisfaction, ED operations, patient safety, pain management, pediatrics, cardiac conditions, respiratory conditions, stroke, and sepsis or infection). Gap analysis suggested the need for new indicators in patient satisfaction, a healthy workplace, mental health and addiction, elder care, and community-hospital integration. Feasibility analysis found that 13 of 48 indicators (27%) can be measured using existing national administrative databases. A broadly representative modified Delphi panel process

  7. Indicators of Coastal Water Quality: Change in Chlorophyll-a Concentration 1998-2007

    Data.gov (United States)

    National Aeronautics and Space Administration — The Change in Chlorophyll-a Concentrations 1998-2007 component of the Indicators of Coastal Water Quality Collection represents a tabular time series of the...

  8. Indicators of Coastal Water Quality: Annual Chlorophyll-a Concentration 1998-2007

    Data.gov (United States)

    National Aeronautics and Space Administration — The Annual Chlorophyll-a Concentrations component of the Indicators of Coastal Water Quality Collection consists of gridded satellite measurements of chlorophyll-a...

  9. Quality indicators for screening colonoscopies and colonoscopist performance and the subsequent risk of interval bowel cancer

    DEFF Research Database (Denmark)

    Lund, Martin; Trads, Mette; Erichsen, Rune

    2017-01-01

    REVIEW QUESTION/OBJECTIVE:: The objective of this systematic review is to assess the association between quality indicators related to the individual colonoscopist's performance and subsequent interval cancers in patients participating in bowel cancer screening programs, following the JBI approach...

  10. Gridded Population of the World, Version 4 (GPWv4): Data Quality Indicators, Revision 10

    Data.gov (United States)

    National Aeronautics and Space Administration — Gridded Population of the World, Version 4 (GPWv4) Data Quality Indicators, Revision 10 consists of three data layers created to provide context for the population...

  11. Considerations on Beam Quality Control in MIT X-Ray FEL

    CERN Document Server

    Wang, Dong; Graves, William; Huang, Gang; Wang, Defa; Wu, Juhao; Zwart, Townsend

    2005-01-01

    The next generation of x-ray FEL requires very high quality electron beams for producing unprecedented x-ray radiations. In proposed x-ray FEL facilities, especially those that use multi-stage high gain high harmonic (HGHG) principle to obtain coherence in both transverse and longitudinal dimensions, the arrival timing of electron bunches must be very precise to ensure the seed laser overlap the desired sections of the electron bunch. A scheme is proposed to achieve 10s fs level of arrival timing control level.

  12. A service for monitoring the quality of intraoperative cone beam CT images

    Directory of Open Access Journals (Sweden)

    Heckel Frank

    2016-09-01

    Full Text Available In recent years, operating rooms (ORs have transformed into integrated operating rooms, where devices are able to communicate, exchange data, or even steer and control each other. However, image data processing is commonly done by dedicated workstations for specific clinical use-cases. In this paper, we propose a concept for a dynamic service component for image data processing on the example of automatic image quality assessment (AQUA of intraoperative cone beam computed tomography (CBCT images. The service is build using the Open Surgical Communication Protocol (OSCP and the standard for Digital Imaging and Communications in Medicine (DICOM. We have validated the proposed concept in an integrated demonstrator OR.

  13. EVALUATION OF QUALITY INDICATORS RELATED TO QUALITY BREAD WHEAT PROMISING LINES

    Directory of Open Access Journals (Sweden)

    Watson Munyanyi

    2014-01-01

    Full Text Available The bread waste is one of the important socio-economic's issues country now, the urgent need is feeling to improve the wheat quality. Therefore, using the methods of farming and breeding is necessary to improve the quality of this strategic product. As a result, tests of quality's traits in wheat promising lines in Isfahan climate took place. In this study, the choice 17 advanced lines of compare the performances,s experiments, an experiment was conducted for two consecutive cropping (2011-2012 at cultural experiment and research centre in Isfahan located in Kabutar Abad region. Randomized complete block designs with 3 replications were compared with Spring variety (for control. Traits including: 1000 grain weight, hectolitre weight, protein content, Zeleny sedimentation rate, bread volume, grain moisture content, grain hardness, water absorption, falling number, percentage of dry gluten, gluten index, sedimentation rates were SDS.The results of the combined analysis of variance qualitative characteristics,s for two consecutive cropping showed that treatments with compare together and control variety had significant influence in 1% probability.Correlation coefficients of two years showed that the compound test significant positive correlation within grain hardness index and protein content, wet gluten and dry deposition rates of SDS. Also, significant positive correlation with the percentage of protein content of dry gluten. In view of the high correlation with protein content of dry gluten (quantity. However, grain hardness and relatively high correlation with SDS sedimentation as an important measure of protein quality. Therefore, the test results of dry gluten grains can be tough to choose in order to improve the quality of wheat bread may be used.

  14. Teaching Quality Management Model for the Training of Innovation Ability and the Multilevel Decomposition Indicators

    Science.gov (United States)

    Lu, Xingjiang; Yao, Chen; Zheng, Jianmin

    2013-01-01

    This paper focuses on the training of undergraduate students' innovation ability. On top of the theoretical framework of the Quality Function Deployment (QFD), we propose a teaching quality management model. Based on this model, we establish a multilevel decomposition indicator system, which integrates innovation ability characterized by four…

  15. Quality indicators for safe medication preparation and administration: a systematic review

    NARCIS (Netherlands)

    Smeulers, Marian; Verweij, Lotte; Maaskant, Jolanda M.; de Boer, Monica; Krediet, C. T. Paul; Nieveen van Dijkum, Els J. M.; Vermeulen, Hester

    2015-01-01

    One-third of all medication errors causing harm to hospitalized patients occur in the medication preparation and administration phase, which is predominantly a nursing activity. To monitor, evaluate and improve the quality and safety of this process, evidence-based quality indicators can be used.

  16. Evaluation of quality indicators for Dutch community pharmacies using a comprehensive assessment framework

    NARCIS (Netherlands)

    Schoenmakers, T.W.A.; Teichert, M.; Braspenning, J.; Vunderink, L.; Smet, P.A.G.M. de; Wensing, M.

    2015-01-01

    BACKGROUND: In 2008, the Dutch Health Care Transparency Programme (Zichtbare Zorg) was set up to develop and apply quality indicators (QIs) for health care. These QIs serve a range of purposes and can be categorized into those for internal use--for meeting quality standards and to continuously

  17. Quality-indicators for palliative care: a review of the literature.

    NARCIS (Netherlands)

    Pasman, H.R.W.; Brandt, H.E.; Deliens, L.; Francke, A.L.

    2009-01-01

    Research has demonstrated a greater understanding of the needs of terminally ill patients and their families, but it also has been found that the palliative care is not optimal. Because of a lack of quality indicators in palliative care, the quality of the care is often not assessed. The aim of this

  18. Indices for the assessment of nutritional quality of meals: a systematic review

    NARCIS (Netherlands)

    Gorgulho, B.M.; Pot, G.K.; Sarti, F.M.; Marchioni, D.M.

    2016-01-01

    This systematic review aimed to synthesise information on indices developed to evaluate nutritional quality of meals. A strategy for systematic search of the literature was developed using keywords related to assessment of meal quality. Databases searched included ScienceDirect, PubMed, Lilacs,

  19. How Well Does Your IEP Measure Up?: Quality Indicators for Effective Service Delivery.

    Science.gov (United States)

    Twachtman-Cullen, Diane; Twachtman-Reilly, Jennifer

    This book is intended to offer guidance in writing individualized education programs (IEPs) that deliver high-quality, need-based educational programming for students with autism spectrum disorders. Following an introductory historical overview of special education law, the remaining chapters in part 1 address the quality indicators for each of…

  20. Home Care Quality Indicators (HCQIS) Based on the MDS-HC

    Science.gov (United States)

    Hirdes, John P.; Fries, Brant E.; Morris, John N.; Ikegami, Naoki; Zimmerman, David; Dalby, Dawn M.; Aliaga, Pablo; Hammer, Suzanne; Jones, Richard

    2004-01-01

    Purpose: This study aimed to develop home care quality indicators (HCQIs) to be used by a variety of audiences including consumers, agencies, regulators, and policy makers to support evidence-based decision making related to the quality of home care services. Design and Methods: Data from 3,041 Canadian and 11,252 U.S. home care clients assessed…

  1. Development of quality indicators based on a multidisciplinary, evidence-based guideline on pediatric constipation

    NARCIS (Netherlands)

    Stienen, J.J.C.; Tabbers, M.M.; Benninga, M.A.; Harmsen, M.; Ouwens, M.M.T.J.

    2011-01-01

    Several clinical guidelines for childhood functional constipation have been developed, but none of them is accompanied by a set of quality indicators. It is important to gain insight into the quality of care in daily practice in order to improve the implementation of clinical guidelines. This can be

  2. European Society of Gynaecologic Oncology Quality Indicators for Advanced Ovarian Cancer Surgery

    NARCIS (Netherlands)

    Querleu, Denis; Planchamp, Francois; Chiva, Luis; Fotopoulou, Christina; Barton, Desmond; Cibula, David; Aletti, Giovanni; Carinelli, Silvestro; Creutzberg, Carien; Davidson, Ben; Harter, Philip; Lundvall, Lene; Marth, Christian; Morice, Philippe; Rafii, Arash; Ray-Coquard, Isabelle; Rockall, Andrea; Sessa, Cristiana; van der Zee, Ate; Vergote, Ignace; du Bois, Andreas

    Objectives The surgical management of advanced ovarian cancer involves complex surgery. Implementation of a quality management program has a major impact on survival. The goal of this work was to develop a list of quality indicators (QIs) for advanced ovarian cancer surgery that can be used to audit

  3. In search of quality indicators for Down syndrome healthcare: a scoping review.

    Science.gov (United States)

    van den Driessen Mareeuw, Francine A; Hollegien, Mirjam I; Coppus, Antonia M W; Delnoij, Diana M J; de Vries, Esther

    2017-04-18

    The medical care chain around Down syndrome (DS) is complex, with many multidisciplinary challenges. The current quality of care is unknown. Outcome-oriented quality indicators have the potential to improve medical practice and evaluate whether innovations are successful. This is particularly interesting for the evolving care for people with DS and intellectual disabilities (ID). The aim of this study was to identify existing indicators for medical DS care, by reviewing the literature. We systematically searched six databases (PubMed, EMBASE, Web of Science, CINAHL, PsycINFO, Google Scholar) for studies concerning the development and implementation of quality indicators for DS and/or ID care, published until February 1 st 2015. The scoping review method was used, including systematic data extraction and stakeholder consultation. We identified 13 studies concerning quality indicators for ID care that obtained data originating from questionnaires (patient/family/staff), medical files and/or national databases. We did not find any indicator sets specifically for DS care. Consulted stakeholders did not come up with additional indicator sets. Existing indicators for ID care predominantly focus on support services. Indicators in care for people with ID targeting medical care are scarce. Of the 70 indicators within the 13 indicator sets, 10% are structure indicators, 34% process, 32% outcome and 24% mixed. Ten of the 13 sets include indicators on the WHO quality dimensions 'patient-centeredness', 'effectiveness' and 'efficiency' of care. 'Accessibility' is covered by nine sets, 'equitability' by six, and 'safety' by four. Most studies developed indicators in a multidisciplinary manner in a joint effort with all relevant stakeholders; some used focus groups to include people with ID. To our knowledge, this is the first review that searched for studies on quality indicators in DS care. Hence, the study contributes to existing knowledge on DS care as well as on measuring

  4. Effects of Grazing and Fire Frequency on Floristic Quality and its Relationship to Indicators of Soil Quality in Tallgrass Prairie

    Science.gov (United States)

    Manning, George C.; Baer, Sara G.; Blair, John M.

    2017-12-01

    Fire and grazing are widely used to manage grasslands for conservation purposes, but few studies have evaluated the effects of these drivers on the conservation value of plant communities measured by the floristic quality index (FQI). Further, the influence of fire and grazing on soil properties and functions are difficult for land managers and restoration practitioners to assess. The objectives of this study were to: (1) quantify the independent and interactive effects of grazing and fire frequency on floristic quality in native tallgrass prairie to provide potential benchmarks for community assessment, and (2) to explore whether floristic quality can serve as an indicator of soil structure and function for more holistic ecosystem assessments. A factorial combination of fire frequencies (1-2, 4, and 20 years return intervals) and grazing (by bison or ungrazed) treatments were sampled for plant species composition, and for several indicators of soil quality in lowland tallgrass prairie. Floristic quality, diversity, and richness were higher in grazed than ungrazed prairie over all fire frequencies ( P < 0.05). Available inorganic N, microbial biomass N, total N, and soil bulk density were also higher in grazed prairie soil over all fire frequencies ( P < 0.05). Microbial biomass C, total organic C, and total soil N were positively correlated with FQI ( P < 0.05). This study shows that floristic quality and soil N pools are more strongly influenced by grazing than fire and that floristic quality can be an indicator of total soil C and N stocks in never cultivated lowland prairie.

  5. Potential Quality Evaluation Method for Radix Astragali Based on Sweetness Indicators

    Directory of Open Access Journals (Sweden)

    Ke Li

    2015-02-01

    Full Text Available Sweetness is a traditional sensory indicator used to evaluate the quality of the popular Chinese herb Radix Astragali (RA. RA roots with strong sweetness are considered to be of good quality. However, neither a thorough analysis of the component(s contributing to RA sweetness, nor a scientific investigation of the reliability of this indicator has been conducted to date. In this study, seven kinds of sweetness components were identified in RA and a quality evaluation method based on these components was established and used to characterize the quality of 48 RA samples. The sweetness evaluation method of RA was first built based on the sweetness components, and a comprehensive evaluation index commonly used in quality control of RA was also derived, which was based on the contents of four indicators (astragaloside IV, calycosin glucoside, polysaccharides and extracts. After evaluating the correlation of these indexes the results showed that the level of sweetness exhibited a strong positive correlation with the proposed comprehensive index. Our results indicate that sweetness is one of the most important quality attributes of RA and thus provide a scientific basis for the utility of the sweetness indicator in quality assessment of this Chinese herb.

  6. Potential quality evaluation method for Radix Astragali based on sweetness indicators.

    Science.gov (United States)

    Li, Ke; Gao, Fanrong; Li, Zhenyu; Qin, Xuemei; Sun, Haifeng; Xing, Jie; Zhang, Lizeng; Du, Guanhua

    2015-02-13

    Sweetness is a traditional sensory indicator used to evaluate the quality of the popular Chinese herb Radix Astragali (RA). RA roots with strong sweetness are considered to be of good quality. However, neither a thorough analysis of the component(s) contributing to RA sweetness, nor a scientific investigation of the reliability of this indicator has been conducted to date. In this study, seven kinds of sweetness components were identified in RA and a quality evaluation method based on these components was established and used to characterize the quality of 48 RA samples. The sweetness evaluation method of RA was first built based on the sweetness components, and a comprehensive evaluation index commonly used in quality control of RA was also derived, which was based on the contents of four indicators (astragaloside IV, calycosin glucoside, polysaccharides and extracts). After evaluating the correlation of these indexes the results showed that the level of sweetness exhibited a strong positive correlation with the proposed comprehensive index. Our results indicate that sweetness is one of the most important quality attributes of RA and thus provide a scientific basis for the utility of the sweetness indicator in quality assessment of this Chinese herb.

  7. Dashboard report on performance on select quality indicators to cancer care providers.

    Science.gov (United States)

    Stattin, Pär; Sandin, Fredrik; Sandbäck, Torsten; Damber, Jan-Erik; Franck Lissbrant, Ingela; Robinson, David; Bratt, Ola; Lambe, Mats

    2016-01-01

    Cancer quality registers are attracting increasing attention as important, but still underutilized sources of clinical data. To optimize the use of registers in quality assurance and improvement, data have to be rapidly collected, collated and presented as actionable, at-a-glance information to the reporting departments. This article presents a dashboard performance report on select quality indicators to cancer care providers. Ten quality indicators registered on an individual patient level in the National Prostate Cancer Register of Sweden and recommended by the National Prostate Cancer Guidelines were selected. Data reported to the National Prostate Cancer Register are uploaded within 24 h to the Information Network for Cancer Care platform. Launched in 2014, "What''s Going On, Prostate Cancer" provides rapid, at-a-glance performance feedback to care providers. The indicators include time to report to the National Prostate Cancer Register, waiting times, designated clinical nurse specialist, multidisciplinary conference, adherence to guidelines for diagnostic work-up and treatment, and documentation and outcome of treatment. For each indicator, three performance levels were defined. What's Going On, a dashboard performance report on 10 selected quality indicators to cancer care providers, provides an example of how data in cancer quality registers can be transformed into condensed, at-a-glance information to be used as actionable metrics for quality assurance and improvement.

  8. The dissolved organic matter as a potential soil quality indicator in arable soils of Hungary.

    Science.gov (United States)

    Filep, Tibor; Draskovits, Eszter; Szabó, József; Koós, Sándor; László, Péter; Szalai, Zoltán

    2015-07-01

    Although several authors have suggested that the labile fraction of soils could be a potential soil quality indicator, the possibilities and limitations of using the dissolved organic matter (DOM) fraction for this purpose have not yet been investigated. The objective of this study was to evaluate the hypothesis that DOM is an adequate indicator of soil quality. To test this, the soil quality indices (SQI) of 190 arable soils from a Hungarian dataset were estimated, and these values were compared to DOM parameters (DOC and SUVA254). A clear difference in soil quality was found between the soil types, with low soil quality for arenosols (average SQI 0.5) and significantly higher values for gleysols, vertisols, regosols, solonetzes and chernozems. The SQI-DOC relationship could be described by non-linear regression, while a linear connection was observed between SQI and SUVA. The regression equations obtained for the dataset showed only one relatively weak significant correlation between the variables, for DOC (R (2) = 0.157(***); n = 190), while non-significant relationships were found for the DOC and SUVA254 values. However, an envelope curve operated with the datasets showed the robust potential of DOC to indicate soil quality changes, with a high R (2) value for the envelope curve regression equation. The limitations to using the DOM fraction of soils as a quality indicator are due to the contradictory processes which take place in soils in many cases.

  9. 100-watt fiber-based green laser with near diffraction-limited beam quality

    Science.gov (United States)

    Hu, Dan; Eisenberg, Eric; Brar, Khush; Yilmaz, Tolga; Honea, Eric

    2010-02-01

    An air-cooled, light-weight, fiber-based, high power green laser has been prototyped. The system consists of an all-fibercoupled IR pump laser at 1064 nm and a frequency-conversion module in a compact and flexible configuration. The IR laser operates in QCW mode, with 10 MHz pulse repetition frequency and 3-5 ns pulse width, to generate sufficient peak power for frequency doubling in the converter module. The IR laser can produce more than 200 W in a linearlypolarized diffraction-limited output beam with high spectral brightness for frequency conversion. The converter module has an input telescope and an oven with a nonlinear crystal to efficiently convert the 1064-nm IR fiber laser output to 532-nm green output. The IR laser and conversion module are connected via a stainless-steel protected delivery fiber for optical beam delivery and an electrical cable harness for electrical power delivery and system control. The beam quality of the 532 nm output remains near diffraction-limited, with M2green laser sources are expected to enable various scientific, defense and industrial applications.

  10. Evidence-based practice: a quality indicator analysis of peer-tutoring in adapted physical education.

    Science.gov (United States)

    Kalef, Laura; Reid, Greg; Macdonald, Cathy

    2013-09-01

    The purpose of the research was to conduct a quality indicator analysis of studies investigating peer-tutoring for students with a disability in adapted physical education. An electronic search was conducted among English journals published from 1960 to November 2012. Databases included ERIC, PsycINFO, and SPORTDiscus. Fifteen research studies employing group-experimental (Gersten et al., 2005) or single-subject designs (Horner et al., 2005) met inclusion criteria. Each study was assessed for the presence and clarity of quality indicators. Group designs met an average of 62.5% essential and 69% desirable indicators. An average of 80% of indicators was present for single-subject designs. Results suggest claims of peer-tutoring being an evidence-based practice are premature. Recommendations for clarifying and applying the quality indicators are offered. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. Air quality indicators from the Environmental Performance Index: potential use and limitations in South Africa

    Directory of Open Access Journals (Sweden)

    Rebecca M. Garland

    2017-06-01

    Full Text Available In responding to deteriorating air quality, many countries, including South Africa, have implemented national programmes that aim to manage and regulate ambient air quality, and the emissions of air pollutants. One aspect within these management strategies is effective communication to stakeholders, including the general public, with regard to the state and trend of ambient air quality in South Africa. Currently, information on ambient air quality is communicated through ambient mass concentration values, as well as number of exceedances of South African National Ambient Standards. However, these do not directly communicate the potential impact on human health and the ecosystem. To this end, the use of air quality indicators is seen as a potential way to achieve communication to stakeholders in a simplified, yet scientifically defensible manner. Air quality indicators and their source data from the Environmental Performance Index (EPI were interrogated to understand their potential use in South Africa. An assessment of four air quality indicators, together with their source data, showed improvements in air quality over the time period studied, though the input data do have uncertainties. The source data for the PM indicators, which came from a global dataset, underestimated the annual PM2.5 concentrations in the Highveld Priority Area and Vaal Triangle Airshed Priority Area over the time period studied (2009-2014 by ~3.7 times. This highlights a key limitation of national-scale indicators and input data, that while the data used by the EPI are a well-thought out estimate of a country’s air quality profile, they remain a generalised estimate. The assumptions and uncertainty inherent in such an ambitious global-wide attempt make the estimates inaccurate for countries without proper emissions tracking and accounting and few monitoring stations, such as South Africa. Thus, the inputs and resultant indicators should be used with caution until such

  12. Detection of Equipment Faults Before Beam Loss

    CERN Document Server

    Galambos, J.

    2016-01-01

    High-power hadron accelerators have strict limits on fractional beam loss. In principle, once a high-quality beam is set up in an acceptable state, beam loss should remain steady. However, in practice, there are many trips in operational machines, owing to excessive beam loss. This paper deals with monitoring equipment health to identify precursor signals that indicate an issue with equipment that will lead to unacceptable beam loss. To this end, a variety of equipment and beam signal measurements are described. In particular, several operational examples from the Spallation Neutron Source (SNS) of deteriorating equipment functionality leading to beam loss are reported.

  13. The quality and outcomes framework in the United kingdom: indicators in transition.

    Science.gov (United States)

    Ashworth, Mark

    2012-01-01

    The United Kingdom's pay-for-performance system, the Quality and Outcomes Framework, continues to evolve. Since its inception in 2004, the Quality and Outcomes Framework has provided a strong focus on evidence-based performance targets that remains a dominant theme. Strengthening of the evidence base has resulted in the appearance of several new clinical indicators. Increasingly, change has been driven by explicit public health goals with targets incentivized according to their potential for mortality reduction. In 2011, a new policy direction became apparent. New indicators accounting for almost 10% of the Quality and Outcomes Framework will be determined by achievement of targets reflecting the efficient use of health service resources.

  14. High quality atomically thin PtSe2 films grown by molecular beam epitaxy

    Science.gov (United States)

    Yan, Mingzhe; Wang, Eryin; Zhou, Xue; Zhang, Guangqi; Zhang, Hongyun; Zhang, Kenan; Yao, Wei; Lu, Nianpeng; Yang, Shuzhen; Wu, Shilong; Yoshikawa, Tomoki; Miyamoto, Koji; Okuda, Taichi; Wu, Yang; Yu, Pu; Duan, Wenhui; Zhou, Shuyun

    2017-12-01

    Atomically thin PtSe2 films have attracted extensive research interests for potential applications in high-speed electronics, spintronics and photodetectors. Obtaining high quality thin films with large size and controlled thickness is critical. Here we report the first successful epitaxial growth of high quality PtSe2 films by molecular beam epitaxy. Atomically thin films from 1 ML to 22 ML have been grown and characterized by low-energy electron diffraction, Raman spectroscopy and x-ray photoemission spectroscopy. Moreover, a systematic thickness dependent study of the electronic structure is revealed by angle-resolved photoemission spectroscopy (ARPES), and helical spin texture is revealed by spin-ARPES. Our work provides new opportunities for growing large size single crystalline films to investigate the physical properties and potential applications of PtSe2.

  15. [Correspondence analysis between traditional commercial specifications and quantitative quality indices of Notopterygii Rhizoma et Radix].

    Science.gov (United States)

    Jiang, Shun-Yuan; Sun, Hong-Bing; Sun, Hui; Ma, Yu-Ying; Chen, Hong-Yu; Zhu, Wen-Tao; Zhou, Yi

    2016-03-01

    This paper aims to explore a comprehensive assessment method combined traditional Chinese medicinal material specifications with quantitative quality indicators. Seventy-six samples of Notopterygii Rhizoma et Radix were collected on market and at producing areas. Traditional commercial specifications were described and assigned, and 10 chemical components and volatile oils were determined for each sample. Cluster analysis, Fisher discriminant analysis and correspondence analysis were used to establish the relationship between the traditional qualitative commercial specifications and quantitative chemical indices for comprehensive evaluating quality of medicinal materials, and quantitative classification of commercial grade and quality grade. A herb quality index (HQI) including traditional commercial specifications and chemical components for quantitative grade classification were established, and corresponding discriminant function were figured out for precise determination of quality grade and sub-grade of Notopterygii Rhizoma et Radix. The result showed that notopterol, isoimperatorin and volatile oil were the major components for determination of chemical quality, and their dividing values were specified for every grade and sub-grade of the commercial materials of Notopterygii Rhizoma et Radix. According to the result, essential relationship between traditional medicinal indicators, qualitative commercial specifications, and quantitative chemical composition indicators can be examined by K-mean cluster, Fisher discriminant analysis and correspondence analysis, which provide a new method for comprehensive quantitative evaluation of traditional Chinese medicine quality integrated traditional commodity specifications and quantitative modern chemical index. Copyright© by the Chinese Pharmaceutical Association.

  16. Characterization of groundwater quality using water evaluation indices, multivariate statistics and geostatistics in central Bangladesh

    Directory of Open Access Journals (Sweden)

    Md. Bodrud-Doza

    2016-04-01

    Full Text Available This study investigates the groundwater quality in the Faridpur district of central Bangladesh based on preselected 60 sample points. Water evaluation indices and a number of statistical approaches such as multivariate statistics and geostatistics are applied to characterize water quality, which is a major factor for controlling the groundwater quality in term of drinking purposes. The study reveal that EC, TDS, Ca2+, total As and Fe values of groundwater samples exceeded Bangladesh and international standards. Ground water quality index (GWQI exhibited that about 47% of the samples were belonging to good quality water for drinking purposes. The heavy metal pollution index (HPI, degree of contamination (Cd, heavy metal evaluation index (HEI reveal that most of the samples belong to low level of pollution. However, Cd provide better alternative than other indices. Principle component analysis (PCA suggests that groundwater quality is mainly related to geogenic (rock–water interaction and anthropogenic source (agrogenic and domestic sewage in the study area. Subsequently, the findings of cluster analysis (CA and correlation matrix (CM are also consistent with the PCA results. The spatial distributions of groundwater quality parameters are determined by geostatistical modeling. The exponential semivariagram model is validated as the best fitted models for most of the indices values. It is expected that outcomes of the study will provide insights for decision makers taking proper measures for groundwater quality management in central Bangladesh.

  17. POPULATION STUDIES OF QUALITY OF LIFE INDICATORS IN THE CITY OF KIZILURT

    Directory of Open Access Journals (Sweden)

    P. A. Bekshokova

    2015-01-01

    Full Text Available Aim. We studied quality of life indicators in the city of Kizilurt (Republic of Dagestan by representative sampling of 1,354 people aged from18 to 86 years (785 women and 569 men. Methods. The study was performed using the SF-36 Health Survey in accordance with the requirements of the International Quality of Life Assessment Project. Results. As the study showed, with age there is a decrease in quality of life among both male and female population. The most marked age-related decline of population quality of life is marked by physical functioning scale. The average values of life quality indicators, studied for 8 scales SF-36, ranged from 59.4 (the scale of general health to 80.5 (the scale of physical functioning. Quality of life of the male population is higher than that of the female on all rating scales of the survey. Thus, we revealed the biggest gender differences on the physical functioning scale, while the smallest on the social functioning scale. Conclusion. These population-based studies of life quality made possible to evaluate the effectiveness of the implementation of various medical and social and economic programs aimed at improving the quality of life and well-being. They can serve as indicators of the environmental component, significantly complementing the overall picture of environmental research. 

  18. Quality control of JEOL JBX-9500FSZ e-beam lithography system in a multi-user laboratory

    DEFF Research Database (Denmark)

    Greibe, Tine; Anhøj, Thomas Aarøe; Johansen, Leif

    2016-01-01

    designed quality control procedure characterized using a scanning electron microscope. We inspect position accuracy, dynamic focus, and dynamic astigmatism, as well as single and multi-pixel lines in thin resist. Beam shape quality is inspected in the corners of the writing field at 6 different beam...... currents between 2 and 60 nA. We use positive-tone resist AR-P6200 (CSAR 62) from All Resist. With our quality control procedure, we routinely write 11 nm lines on a 40 nm pitch, and obtain a field stitching accuracy better than 3 nm and overlay accuracy less than 7 nm....

  19. Effects of Grazing and Fire Frequency on Floristic Quality and its Relationship to Indicators of Soil Quality in Tallgrass Prairie.

    Science.gov (United States)

    Manning, George C; Baer, Sara G; Blair, John M

    2017-12-01

    Fire and grazing are widely used to manage grasslands for conservation purposes, but few studies have evaluated the effects of these drivers on the conservation value of plant communities measured by the floristic quality index (FQI). Further, the influence of fire and grazing on soil properties and functions are difficult for land managers and restoration practitioners to assess. The objectives of this study were to: (1) quantify the independent and interactive effects of grazing and fire frequency on floristic quality in native tallgrass prairie to provide potential benchmarks for community assessment, and (2) to explore whether floristic quality can serve as an indicator of soil structure and function for more holistic ecosystem assessments. A factorial combination of fire frequencies (1-2, 4, and 20 years return intervals) and grazing (by bison or ungrazed) treatments were sampled for plant species composition, and for several indicators of soil quality in lowland tallgrass prairie. Floristic quality, diversity, and richness were higher in grazed than ungrazed prairie over all fire frequencies (P soil bulk density were also higher in grazed prairie soil over all fire frequencies (P soil N were positively correlated with FQI (P soil N pools are more strongly influenced by grazing than fire and that floristic quality can be an indicator of total soil C and N stocks in never cultivated lowland prairie.

  20. INSTABILITY OF QUALITY WHITE AND RED WINES WITHOUT A GEOGRAPHICAL INDICATION MARKETED IN COMMERCIAL CHAINS

    Directory of Open Access Journals (Sweden)

    Peter Czako

    2013-02-01

    Full Text Available Wine in the quality category without geographical indications in consumer glass containers with a distinctive label are sold in the largest quantities in the lowest price level. These wines are the most prevalent in multinational trade chains. For this reason, we have focused on the quality and sustainability of quality of these wines on sale. Date of minimum durability is optional and voluntary indication for wines. In the sale, however, we meet as well with the wines, which are offered to the consumer, and are exposed at the point of even a few years. In our pursuit it has been clearly shown that the date of minimum expiration stated on the prepackaging wines without geographical indication would be justified and vouched by the consumer to the sustainability of quality wines.

  1. Usability Evaluation and Implementation of a Health Information Technology Dashboard of Evidence-Based Quality Indicators.

    Science.gov (United States)

    Schall, Mark Christopher; Cullen, Laura; Pennathur, Priyadarshini; Chen, Howard; Burrell, Keith; Matthews, Grace

    2017-06-01

    Health information technology dashboards that integrate evidence-based quality indicators can efficiently and accurately display patient risk information to promote early intervention and improve overall quality of patient care. We describe the process of developing, evaluating, and implementing a dashboard designed to promote quality care through display of evidence-based quality indicators within an electronic health record. Clinician feedback was sought throughout the process. Usability evaluations were provided by three nurse pairs and one physician from medical-surgical areas. Task completion times, error rates, and ratings of system usability were collected to compare the use of quality indicators displayed on the dashboard to the indicators displayed in a conventional electronic health record across eight experimental scenarios. Participants rated the dashboard as "highly usable" following System Usability Scale (mean, 87.5 [SD, 9.6]) and Poststudy System Usability Questionnaire (mean, 1.7 [SD, 0.5]) criteria. Use of the dashboard led to reduced task completion times and error rates in comparison to the conventional electronic health record for quality indicator-related tasks. Clinician responses to the dashboard display capabilities were positive, and a multifaceted implementation plan has been used. Results suggest application of the dashboard in the care environment may lead to improved patient care.

  2. Evaluation of the Beam Quality of Intraoral X-ray Equipment using Intraoral Standard Films

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sang Sub; Kwon, Hyok Rak; Sim, Woo Hyoun; Oh, Seung Hyoun; Lee, Ji Youn; Jeon, Kug Jin; Kim, Kee Deog; Park, Chang Seo [Dept. of Oral and Maxillofacial Radiology, College of Dentistry, Yensei University, Seoul (Korea, Republic of)

    2000-09-15

    This study was to evaluate the beam quality of intraoral X-ray equipment used at Yonsei University Dental Hospital (YUDH) using the half value layer (HVL) and the characteristic curve of intraoral standard X-ray film. The study was done using the intraoral X-ray equipment used at each clinical department at YUDH. Aluminum filter was used to determine the HVL. Intraoral standard film was used to get the characteristic curve of each intraoral X-ray equipment. Most of the HVLs of intraoral X-ray equipment were higher than the least recommended thickness, but the REX 601 model used at the operative dentistry department and the X-707 model used at the pediatric dentistry department had HVLs lower than the recommended thickness. The slopes of the characteristic curves of films taken using the PANPAS 601 model and REX 601 model at operative dentistry department, the X-70S model of prosthodontic dentistry department, and the REX 601 model at the student clinic were relatively low. HVL and the characteristic curve of X-ray film can be used to evaluate the beam quality of intraoral X-ray equipment. In order to get the best X-ray films with the least radiation exposure to patients and best diagnostic information in clinical dentistry, X-ray equipment should be managed in the planned and organized fashion.

  3. Evaluation of the Beam Quality of Intraoral X-ray Equipment using Intraoral Standard Films

    International Nuclear Information System (INIS)

    Lee, Sang Sub; Kwon, Hyok Rak; Sim, Woo Hyoun; Oh, Seung Hyoun; Lee, Ji Youn; Jeon, Kug Jin; Kim, Kee Deog; Park, Chang Seo

    2000-01-01

    This study was to evaluate the beam quality of intraoral X-ray equipment used at Yonsei University Dental Hospital (YUDH) using the half value layer (HVL) and the characteristic curve of intraoral standard X-ray film. The study was done using the intraoral X-ray equipment used at each clinical department at YUDH. Aluminum filter was used to determine the HVL. Intraoral standard film was used to get the characteristic curve of each intraoral X-ray equipment. Most of the HVLs of intraoral X-ray equipment were higher than the least recommended thickness, but the REX 601 model used at the operative dentistry department and the X-707 model used at the pediatric dentistry department had HVLs lower than the recommended thickness. The slopes of the characteristic curves of films taken using the PANPAS 601 model and REX 601 model at operative dentistry department, the X-70S model of prosthodontic dentistry department, and the REX 601 model at the student clinic were relatively low. HVL and the characteristic curve of X-ray film can be used to evaluate the beam quality of intraoral X-ray equipment. In order to get the best X-ray films with the least radiation exposure to patients and best diagnostic information in clinical dentistry, X-ray equipment should be managed in the planned and organized fashion.

  4. Key team physical and technical performance indicators indicative of team quality in the soccer Chinese super league.

    Science.gov (United States)

    Yang, Gai; Leicht, Anthony S; Lago, Carlos; Gómez, Miguel-Ángel

    2018-01-01

    The aim of this study was to identify the key physical and technical performance variables related to team quality in the Chinese Super League (CSL). Teams' performance variables were collected from 240 matches and analysed via analysis of variance between end-of-season-ranked groups and multinomial logistic regression. Significant physical performance differences between groups were identified for sprinting (top-ranked group vs. upper-middle-ranked group) and total distance covered without possession (upper and upper-middle-ranked groups and lower-ranked group). For technical performance, teams in the top-ranked group exhibited a significantly greater amount of possession in opponent's half, number of entry passes in the final 1/3 of the field and the Penalty Area, and 50-50 challenges than lower-ranked teams. Finally, time of possession increased the probability of a win compared with a draw. The current study identified key performance indicators that differentiated end-season team quality within the CSL.

  5. Clinical nursing leaders' perceptions of nutrition quality indicators in Swedish stroke wards: a national survey.

    Science.gov (United States)

    Persenius, Mona; Hall-Lord, Marie-Louise; Wilde-Larsson, Bodil; Carlsson, Eva

    2015-09-01

    To describe nursing leaders' perceptions of nutrition quality in Swedish stroke wards. A high risk of undernutrition places great demand on nutritional care in stroke wards. Evidence-based guidelines exist, but healthcare professionals have reported low interest in nutritional care. The Donabedian framework of structure, process and outcome is recommended to monitor and improve nutrition quality. Using a descriptive cross-sectional design, a web-based questionnaire regarding nutritional care quality was delivered to eligible participants. Most clinical nursing leaders reported structure indicators, e.g. access to dieticians. Among process indicators, regular assessment of patients' swallowing was most frequently reported in comprehensive stroke wards compared with other stroke wards. Use of outcomes to monitor nutrition quality was not routine. Wards using standard care plans showed significantly better results. Using the structure, process and outcome framework to examine nutrition quality, quality-improvement needs became visible. To provide high-quality nutrition, all three structure, process and outcome components must be addressed. The use of care pathways, standard care plans, the Senior Alert registry, as well as systematic use of outcome measures could improve nutrition quality. To assist clinical nursing leaders in managing all aspects of quality, structure, process and outcome can be a valuable framework. © 2013 John Wiley & Sons Ltd.

  6. A Comprehensive Real-Time Indoor Air-Quality Level Indicator

    Directory of Open Access Journals (Sweden)

    Jungho Kang

    2016-09-01

    Full Text Available The growing concern about Indoor Air-Quality has accelerated the development of small, low-cost air-quality monitoring systems. These systems are capable of monitoring various indoor air pollutants in real time, notifying users about the current air-quality status and gathering the information to the central server. However, most Internet of Things (IoT-based air-quality monitoring systems numerically present the sensed value per pollutant, making it difficult for general users to identify how polluted the air is. Therefore, in this paper, we first introduce a tiny air-quality monitoring system that we developed and, based on the system, we also test the applicability of the comprehensive Air-Quality Index (AQI, which is widely used all over the world, in terms of its capacity for a comprehensive indoor air-quality indication. We also develop design considerations for an IoT-based air-quality monitoring system and propose a real-time comprehensive indoor air-quality level indication method, which effectively copes with dynamic changes and is efficient in terms of processing and memory overhead.

  7. Race-Related Stress, Quality of Life Indicators, and Life Satisfaction among Elderly African Americans.

    Science.gov (United States)

    Utsey, Shawn O.; Payne, Yasser A.; Jackson, Ebonique S.; Jones, Antoine M.

    2002-01-01

    Examines the relationships among race-related stress, quality of life indicators, and life satisfaction among elderly African Americans. Results indicated that elderly African American men and women differed significantly with regard to institutional and collective racism-related stress. In addition, institutional racism-related stress was a…

  8. Assessment of water quality based on diatom indices in a small ...

    African Journals Online (AJOL)

    Canonical correspondence analysis (CCA) demonstrated that variations in the benthic diatom community structure were best explained by ammonium, nitrate, conductivity, pH, temperature, resistivity and water flow. OMNIDIA was used for calculation of selected diatom water quality indices. A number of the indices, e.g., the ...

  9. Postpartum haemorrhage in midwifery care in the Netherlands: validation of quality indicators for midwifery guidelines.

    Science.gov (United States)

    Smit, Marrit; Chan, Kar-Li L; Middeldorp, Johanna M; van Roosmalen, Jos

    2014-12-07

    Postpartum haemorrhage (PPH) is still one of the major causes of severe maternal morbidity and mortality worldwide. Currently, no guideline for PPH occurring in primary midwifery care in the Netherlands is available. A set of 25 quality indicators for prevention and management of PPH in primary care has been developed by an expert panel consisting of midwives, obstetricians, ambulance personal and representatives of the Royal Dutch College of Midwives (KNOV) and the Dutch Society of Obstetrics and Gynecology (NVOG). This study aims to assess the performance of these quality indicators as an assessment tool for midwifery care and suitability for incorporation in a professional midwifery guideline. From April 2008 to April 2010, midwives reported cases of PPH. Cases were assessed using the 25 earlier developed quality indicators. Quality criteria on applicability, feasibility, adherence to the indicator, and the indicator's potential to monitor improvement were assessed. 98 cases of PPH were reported during the study period, of which 94 were analysed. Eleven indicators were found to be applicable and feasible. Five of these indicators showed improvement potential: routine administration of uterotonics, quantifying blood loss by weighing, timely referral to secondary care in homebirth and treatment of PPH using catherisation, uterine massage and oxytocin and the use of oxygen. Eleven out of 25 indicators were found to be suitable as an assessment tool for midwifery care of PPH and are therefore suitable for incorporation in a professional midwifery guideline. Larger studies are necessary to confirm these results.

  10. [Assessing the balance of quality indicator sets of external quality assurance according to SGB V section 136].

    Science.gov (United States)

    Doebler, Klaus; Geraedts, Max

    2017-12-20

    The value and usefulness of the results of indicator-based performance measurement in healthcare for different purposes do not only depend on the methodological quality of the individual indicators but also on the composition of the indicator sets. So far, the balance of the currently used indicator sets of the German mandatory national performance measurement system for hospitals has not been systematically analyzed. Due to the lack of a methodological gold standard for the assessment of balance and orientation of indicator sets we adapted the OECD concept of quality dimensions and defined four categories: 1) "Achieving primary goals of treatment", 2) "Avoiding adverse events", 3) "Indication" and 4) "Patient-centeredness". We defined rules for the assignment to the categories and analyzed the distribution of the 239 indicators from 29 medical areas in relation to these categories. 63 indicators (26.4 %) were assigned to the category "Achieving primary goals of treatment", 153 (64.0 %) to the category "Avoiding adverse events", 18 (7.5 %) to the category "Indication", one indicator (0.4 %) to the category "Patient-centeredness". Four indicators (1.7 %) addressed documentation quality. 12 of the 29 indicator sets only covered one OECD quality dimension by at least one indicator. The current indicator sets seem to be unbalanced with a strong focus on the category "Avoiding adverse events". As regards the goal of monitoring the compliance with minimal safety standards and performing improvement interventions, the direction of the indicator sets seems to be appropriate. With respect to other goals, such as for example the identification of "excellence", further development efforts are required. One relevant reason for the dominant focus on the category "Avoiding adverse events" seems to be that data sources for a follow-up and for the inclusion of the patient perspective have not been available until recently. There is a strong demand for the consequent use of

  11. Developing Indicators of Service Quality Provided for Cardiovascular Patients Hospitalized in Cardiac Care Unit

    Directory of Open Access Journals (Sweden)

    Saber Azami-Aghdash

    2013-03-01

    Full Text Available Introduction: Cardiovascular diseases are among the most prevalent chronic diseases leading to high degrees of mortality and morbidity worldwide and in Iran. The aim of the current study was to determine and develop appropriate indicators for evaluating provided service quality for cardiovascular patients admitted to Cardiac Care Units (CCU in Iran. Methods: In order to determine the indicators for evaluating provided service quality, a four-stage process including reviewing systematic review articles in premier bibliographic databases, interview, performing two rounds of Delphi technique, and holding experts panel by attendance of experts in different fields was adopted. Finally, after recognizing relevant indicators in resources, these indicators were finalized during various stages using ideas of 27 experts in different fields. Results: Among 2800 found articles in the text reviewing phase, 21 articles, which had completely mentioned relevant indicators, were studied and 48 related indicators were extracted. After two interviews with a cardiologist and an epidemiologist, 32 items of the indicators were omitted and replaced by 27 indicators coping with the conditions of Iranian hospitals. Finally, 43 indicators were added into the Delphi phase and after 2 rounds of Delphi with 18 specialists, 7 cases were excluded due to their low scores of applicability. In the experts’ panel stage, 6 items were also omitted and 10 new indicators were developed to replace them. Eventually, 40 indicators were finalized. Conclusion: In this study, some proper indicators for evaluating provided service quality for CCU admissions in Iran were determined. Considering the informative richness of these indicators, they can be used by managers, policy makers, health service providers, and also insurance agencies in order to improve the quality of services, decisions, and policies.

  12. Should image rotation be addressed during routine cone-beam CT quality assurance?

    International Nuclear Information System (INIS)

    Ayan, Ahmet S; Lin Haibo; Yeager, Caitlyn; Deville, Curtiland; McDonough, James; Zhu, Timothy C; Anderson, Nathan; Ad, Voichita Bar; Both, Stefan; Lu, Hsiao-Ming

    2013-01-01

    The purpose of this study is to investigate whether quality assurance (QA) for cone-beam computed tomography (CBCT) image rotation is necessary in order to ensure the accuracy of CBCT based image-guided radiation therapy (IGRT) and adaptive radiotherapy (ART). Misregistration of angular coordinates during CBCT acquisition may lead to a rotated reconstructed image. If target localization is performed based on this image, an under- or over-dosage of the target volume (TV) and organs at risk (OARs) may occur. Therefore, patient CT image sets were rotated by 1° up to 3° and the treatment plans were recalculated to quantify changes in dose–volume histograms. A computer code in C++ was written to model the TV displacement and overlap area of an ellipse shape at the target and dose prescription levels corresponding to the image rotation. We investigated clinical scenarios in IGRT and ART in order to study the implications of image rotation on dose distributions for: (1) lateral TV and isocenter (SBRT), (2) central TV and isocenter (IMRT), (3) lateral TV and isocenter (IMRT). Mathematical analysis showed the dose coverage of TV depends on its shape, size, location, and orientation relative to the isocenter. Evaluation of three first scenario for θ = 1° showed variations in TV D95 in the context of IGRT and ART when compared to the original plan were within 2.7 ± 2.6% and 7.7 ± 6.9% respectively while variations in the second and third scenarios were less significant (<0.5%) for the angular range evaluated. However a larger degree of variation was found in terms of minimum and maximum doses for target and OARs. The rotation of CBCT image data sets may have significant dosimetric consequences in IGRT and ART. The TV's location relative to isocenter and shape determine the extent of alterations in dose indicators. Our findings suggest that a CBCT QA criterion of 1° would be a reasonable action level to ensure accurate dose delivery. (paper)

  13. SU-F-T-338: Flattening Filter Free Photon Beams Can Achieve the Same Plan Quality as Conventional Flattened Beams for Prostate Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Kolar, M; Szwedowski, R; Greskovich, J; Xia, P [Cleveland Clinic, Cleveland, OH (United States)

    2016-06-15

    Purpose: Some modern linear accelerators are equipped with one low energy flat beam and two flattening filter free (FFF) beams at high and low energies. The purpose of this study is to investigate whether the high energy FFF beam can produce the same plan quality as the conventional low energy flat beam, using a volumetric modulated arc (VMAT) technique for prostate patients. Methods: Ten prostate cancer patients were selected with a prescription of 78Gy. For each patient, three plans were created: (a) double arc flat 6MV plan used clinically; (b) double arc 10MV FFF plan; (c) single arc 10MV FFF plan. Each plan was prescribed so that at least 95% of the PTV received the prescription dose. The following dosimetric endpoints were evaluated: volume receiving 78Gy (V78) of the CTV and PTV, PTV conformality index (CI, ratio of prescription isodose volume to the PTV volume), bladder volume receiving 70Gy (V70) and 60Gy (V60), rectum volume receiving 70Gy (V70) and 50Gy (V50), dose to 10cc of the rectum, and volume of both femoral heads receiving 50Gy (V50). Total monitor units for each plan were recorded. Results: No significant difference was found for all dosimetric endpoints between all plans (p>0.05). Compared to the 6MV plans, monitor units were higher with the double arc 10MV FFF plans and lower with the single arc 10MV FFF plans, 29% and 4% respectively. Conclusion: Both single arc and double arc 10MV FFF VMAT can achieve equivalent plan quality as 6MV flat beam double arc treatment plans. With the gantry speed restriction, a high dose rate of 2400MU/min may allow the optimizer to use more MUs than actually needed. Single arc 10MV FFF VMAT plans are a reasonable alternative to double arc 6MV flat beam VMAT plans.

  14. Quality indicators for initial licensure and discipline in nursing laws in South Korea and North Carolina.

    Science.gov (United States)

    Kim, K K; Kjervik, D K; Foster, B

    2014-03-01

    The Korean regulatory framework of nursing licensure reflects that of the USA, but its content differs in some of the powers related to quality assurance. This article compares regulatory quality indicators and describes core standards in nursing regulations that are related to both initial licensure and discipline for three groups: the National Council of State Boards of Nursing, the North Carolina and the South of Korea. A descriptive, comparative law design is used to examine the differences and similarities in the quality indicators and core standards found in three documents: the National Council of State Boards of Nursing Model Act, the North Carolina Nursing Practice Act and the Korean Medical Service Act for registered nurses. The findings indicate that ten quality indicators and two standards appear in study objects. Although most of the quality indicators are common to all documents, some differences are found in terms of the scope of criminal background checks and the range of grounds for disciplinary action. These findings cannot be generalized in the USA because although the North Carolina nursing act was selected as an example of US nursing laws, nursing laws differ somewhat across states. This comparative study shows a clear opportunity to develop indicators that acknowledge the important areas of competence and good moral character and how they can improve patient safety in Korea. This study provides recommendations for Korean nursing legislative redesign and pointers for other jurisdictions to consider. © 2013 International Council of Nurses.

  15. [A set of quality and safety indicators for hospitals of the "Agencia Valenciana de Salud"].

    Science.gov (United States)

    Nebot-Marzal, C M; Mira-Solves, J J; Guilabert-Mora, M; Pérez-Jover, V; Pablo-Comeche, D; Quirós-Morató, T; Cuesta Peredo, D

    2014-01-01

    To prepare a set of quality and safety indicators for Hospitals of the «Agencia Valenciana de Salud». The qualitative technique Metaplan® was applied in order to gather proposals on sustainability and nursing. The catalogue of the «Spanish Society of Quality in Healthcare» was adopted as a starting point for clinical indicators. Using the Delphi technique, 207 professionals were invited to participate in the selecting the most reliable and feasible indicators. Lastly, the resulting proposal was validated with the managers of 12 hospitals, taking into account the variability, objectivity, feasibility, reliability and sensitivity, of the indicators. Participation rates varied between 66.67% and 80.71%. Of the 159 initial indicators, 68 were prioritized and selected (21 economic or management indicators, 22 nursing indicators, and 25 clinical or hospital indicators). Three of them were common to all three categories and two did not match the specified criteria during the validation phase, thus obtaining a final catalogue of 63 indicators. A set of quality and safety indicators for Hospitals was prepared. They are currently being monitored using the hospital information systems. Copyright © 2013 SECA. Published by Elsevier Espana. All rights reserved.

  16. Effects of Electron Beam Irradiation on Zearalenone and Ochratoxin A in Naturally Contaminated Corn and Corn Quality Parameters

    Directory of Open Access Journals (Sweden)

    Xiaohu Luo

    2017-02-01

    Full Text Available Zearalenone (ZEN and ochratoxin A (OTA are secondary toxic metabolites widely present in grains and grain products. In this study, the effects of electron beam irradiation (EBI on ZEN and OTA in corn and the quality of irradiated corn were investigated. Results indicated that EBI significantly affected ZEN and OTA. The degradation rates of ZEN and OTA at 10 kGy in solution were 65.6% and 75.2%, respectively. The initial amounts significantly affected the degradation rate. ZEN and OTA in corn were decreased by the irradiation dose, and their degradation rates at 50 kGy were 71.1% and 67.9%, respectively. ZEN and OTA were more easily degraded in corn kernel than in corn flour. Moisture content (MC played a vital role in ZEN and OTA degradation. High MC was attributed to high ZEN and OTA degradation. The quality of irradiated corn was evaluated on the basis of irradiation dose. L* value changed, but this change was not significant (p > 0.05. By contrast, a* and b* decreased significantly (p < 0.05 with irradiation dose. The fatty acid value increased significantly. The pasting properties, including peak, trough, breakdown, and final and setback viscosities, were also reduced significantly (p < 0.05 by irradiation. Our study verified that EBI could effectively degrade ZEN and OTA in corn. Irradiation could also affect corn quality.

  17. Comparison of the effects of gamma ray and e-beam irradiation on the quality of minced beef during storage

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jae Nam; Han, In Jun; Kim, Wang Geun; Song, Beom Seok; Kim, Jae Hun; Choi, Jong Il; Yoon, Yo Han; Byun, Myung Woo; Hwang, Han Joon; Lee, Ju Woon [Korea Atomic Energy Research Institte, Jeongeup (Korea, Republic of); Park, Jin Gyu [Korea University, Seoul (Korea, Republic of)

    2009-06-15

    This study was conducted to compare the microbiological and physicochemical qualities of minced beef irradiated with gamma ray of e-beam at the absorbed doses from 5 to 20 kGy. The total bacterial counts of minced beef were decreased depending upon the irradiation doses, but sterilizing effect of gamma irradiation was higher than that of e-beam irradiation. The contents of malondialdegyde of minced beef were increased depending upon irradiation doses as well as storage periods (p< 0.05). Volatile basic nitrogen in minced beef was constantly increased during storage, but the increasing rate were retarded by irradiation. The hunter's color values(L*, a* and b*) of gamma or e-beam irradiated minced beef were decreased as irradiation dose increasing. Meanwhile, the quality changes of gamma irradiated samples were faster than e-beam irradiated samples.

  18. Counter-crossing injection for stable high-quality electron beam generation via laser-plasma interaction

    Energy Technology Data Exchange (ETDEWEB)

    Kotaki, H; Daito, I; Hayashi, Y; Ma, J; Chen, L-M; Kando, M; Esirkepov, T Z; Fukuda, Y; Homma, T; Pirozhkov, A; Koga, J K; Nakajima, K; Daido, H; Bulanov, S V [Advanced Photon Research Center, Japan Atomic Energy Agency, Kizugawa, Kyoto (Japan)], E-mail: kotaki.hideyuki@jaea.go.jp

    2008-05-01

    Counter-crossing injection, which is a realistic setup for applications, by two sub-relativistic laser pulses colliding at an angle of 45 degrees is demonstrated. The collision of the two laser pulses generates a high-quality electron beam with high reproducibility. The generated monoenergetic electron beam has a peak energy of 14.4 MeV, an energy spread of 10.6%, a charge of 21.8 pC, a normalized emittance of 1.6 {pi} mm mrad, and a reproducibility of 50%. The electron beam generation is unfolded with two-dimensional-particle-in-cell simulations. The laser pulses in plasma are self-focused to higher intensity when the laser power is above the threshold for relativistic self-focusing. The collision of the self-focused laser pulses generates a high-quality electron beam with high reproducibility.

  19. SU-F-T-276: Source Modeling and VMAT Quality Assurance Referring to the TrueBeam Representative Beam Data for Eclipse

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Q [Beijing Hospital, Beijing (China)

    2016-06-15

    Purpose: To study quality assurance (QA) of volumetric modulated arc therapy (VMAT) after the 6MV and 10MV photon beam source modeling, referring to the Varian TrueBeam representative beam data for Eclipse. Methods: The source model needs specific measured beam data, such as PDDs and profiles, diagonal profile, output factors (OFs), and MLC transmission factor (TF) and dosimetric leaf gap (DLG), et al. We downloaded the representative data from myVarian website, which includes TrueBeam 4MV-15MV photon beam data and 6MeV-22MeV electron beam data in w2CAD file format for use with Eclipse and in Excel spreadsheet format for use in data comparison. The beam data in W2CAD format can be imported into the Eclipse system and calibrated for use, as appropriate. We used PTW MP3 water tank to measure the beam data in some typical field sizes, and compared the measured data with the representative data. We found that the PDDs, profiles and OFs are similar. However according to some papers and our measurements, we decided that our MLC TF and DLG are 1.58 and 1.33 (6MV), 1.79 and 1.57 (10MV), respectively. After we had configured the anisotropic analytical algorithm (AAA) with the representative data in Eclipse, we also have done dosimetric verification for 88 VMAT plans. Results: The end-to-end test procedures of VMAT were performed for 6MV and 10MV energy modes. The NE Farmer ion chamber mean measurements showed 1.2% (6MV, 38 cases) and 1.2% (10MV, 50 cases) between measurement and calculation; the Sun Nuclear ArcCheck mean measurements demonstrated gamma pass rates are as followings: 98.9%, 93.2%, 61.0% for 6MV, and 98.9%, 91.9%, 59.5% for 10MV, using 3%/3mm, 2%/2mm, 1%/1mm, 10% threshold criteria, respectively. Conclusion: The representative data is applicable to our TrueBeam for the VMAT plan, though our MLC factors are a little different, and its patientspecific QA is good.

  20. Tailoring the laser pulse shape to improve the quality of the self-injected electron beam in laser wakefield acceleration

    International Nuclear Information System (INIS)

    Upadhyay, Ajay K.; Samant, Sushil A.; Krishnagopal, S.

    2013-01-01

    In laser wakefield acceleration, tailoring the shape of the laser pulse is one way of influencing the laser-plasma interaction and, therefore, of improving the quality of the self-injected electron beam in the bubble regime. Using three-dimensional particle-in-cell simulations, the evolution dynamics of the laser pulse and the quality of the self-injected beam, for a Gaussian pulse, a positive skew pulse (i.e., one with sharp rise and slow fall), and a negative skew pulse (i.e., one with a slow rise and sharp fall) are studied. It is observed that with a negative skew laser pulse there is a substantial improvement in the emittance (by around a factor of two), and a modest improvement in the energy-spread, compared to Gaussian as well as positive skew pulses. However, the injected charge is less in the negative skew pulse compared to the other two. It is also found that there is an optimal propagation distance that gives the best beam quality; beyond this distance, though the energy increases, the beam quality deteriorates, but this deterioration is least for the negative skew pulse. Thus, the negative skew pulse gives an improvement in terms of beam quality (emittance and energy spread) over what one can get with a Gaussian or positive skew pulse. In part, this is because of the lesser injected charge, and the strong suppression of continuous injection for the negative skew pulse.

  1. Review article: what makes a good healthcare quality indicator? A systematic review and validation study.

    Science.gov (United States)

    Jones, Peter; Shepherd, Michael; Wells, Susan; Le Fevre, James; Ameratunga, Shanthi

    2014-04-01

    Indicators measuring aspects of performance to assess quality of care are often chosen arbitrarily. The present study aimed to determine what should be considered when selecting healthcare quality indicators, particularly focusing on the application to emergency medicine. Structured searches of electronic databases were supplemented by website searches of quality of care and benchmarking organisations, citation searches and discussions with experts. Candidate attributes of 'good' healthcare indicators were extracted independently by two authors. The validity of each attribute was independently assessed by 16 experts in quality of care and emergency medicine. Valid and reliable attributes were included in a critical appraisal tool for healthcare quality indicators, which was piloted by emergency medicine specialists. Twenty-three attributes were identified, and all were rated moderate to extremely important by an expert panel. The reliability was high: alpha = 0.98. Twelve existing tools explicitly stated a median (range) of 14 (8-17) attributes. A critical appraisal tool incorporating all the attributes was developed. This was piloted by four emergency medicine specialists who were asked to appraise and rank a set of six candidate indicators. Although using the tool took more time than implicit gestalt decision making: median (interquartile range) 190 (43-352) min versus 17.5 (3-34) min, their rankings changed after using the tool. To inform the appraisal of quality improvement indicators for emergency medicine, a comprehensive list of indicator attributes was identified, validated, developed into a tool and piloted. Although expert consensus is still required, this tool provides an explicit basis for discussions around indicator selection. © 2014 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.

  2. Assessing the validity of indicators of the quality of maternal and newborn health care in Kenya

    Directory of Open Access Journals (Sweden)

    Ann K Blanc 1

    2016-06-01

    Full Text Available The measurement of progress in maternal and newborn health often relies on data provided by women in surveys on the quality of care they received. The majority of these indicators, however, including the widely tracked “skilled attendance at birth” indicator, have not been validated. We assess the validity of a large set of maternal and newborn health indicators that are included or have the potential to be included in population–based surveys.

  3. The impact of removing financial incentives from clinical quality indicators: longitudinal analysis of four Kaiser Permanente indicators.

    Science.gov (United States)

    Lester, Helen; Schmittdiel, Julie; Selby, Joe; Fireman, Bruce; Campbell, Stephen; Lee, Janelle; Whippy, Alan; Madvig, Philip

    2010-05-11

    To evaluate the effect of financial incentives on four clinical quality indicators common to pay for performance plans in the United Kingdom and at Kaiser Permanente in California. Longitudinal analysis. 35 medical facilities of Kaiser Permanente Northern California, 1997-2007. 2 523 659 adult members of Kaiser Permanente Northern California. Main outcomes measures Yearly assessment of patient level glycaemic control (HbA(1c) financial incentives were attached to screening for diabetic retinopathy (1999-2003), the rate rose from 84.9% to 88.1%. This was followed by four years without incentives when the rate fell year on year to 80.5%. During the two initial years when financial incentives were attached to cervical cancer screening (1999-2000), the screening rate rose slightly, from 77.4% to 78.0%. During the next five years when financial incentives were removed, screening rates fell year on year to 74.3%. Incentives were then reattached for two years (2006-7) and screening rates began to increase. Across the 35 facilities, the removal of incentives was associated with a decrease in performance of about 3% per year on average for screening for diabetic retinopathy and about 1.6% per year for cervical cancer screening. Policy makers and clinicians should be aware that removing facility directed financial incentives from clinical indicators may mean that performance levels decline.

  4. Identifying individual changes in performance with composite quality indicators while accounting for regression to the mean.

    Science.gov (United States)

    Gajewski, Byron J; Dunton, Nancy

    2013-04-01

    Almost a decade ago Morton and Torgerson indicated that perceived medical benefits could be due to "regression to the mean." Despite this caution, the regression to the mean "effects on the identification of changes in institutional performance do not seem to have been considered previously in any depth" (Jones and Spiegelhalter). As a response, Jones and Spiegelhalter provide a methodology to adjust for regression to the mean when modeling recent changes in institutional performance for one-variable quality indicators. Therefore, in our view, Jones and Spiegelhalter provide a breakthrough methodology for performance measures. At the same time, in the interests of parsimony, it is useful to aggregate individual quality indicators into a composite score. Our question is, can we develop and demonstrate a methodology that extends the "regression to the mean" literature to allow for composite quality indicators? Using a latent variable modeling approach, we extend the methodology to the composite indicator case. We demonstrate the approach on 4 indicators collected by the National Database of Nursing Quality Indicators. A simulation study further demonstrates its "proof of concept."

  5. Health care quality indicators on the management of rheumatoid arthritis and osteoarthritis: a literature review.

    Science.gov (United States)

    Strömbeck, Britta; Petersson, Ingemar F; Vliet Vlieland, Theodora P M

    2013-02-01

    To make an inventory of quality and content of currently available and published sets of health care quality indicators (HCQIs) for RA and OA. A systematic review was performed for documents on the development and/or a description of HCQIs for the management of patients with RA and/or OA, using the PubMed, EMBASE, Web of Science, Cochrane and CINAHL databases up to 1 December 2010 and official websites of arthritis organizations. The following data were extracted: general characteristics, contents and quality of developmental process (six aspects related to the definition of target, target group and stakeholders, patient involvement, description of development and test of validity). The search yielded 498 potentially eligible references and two websites, with ultimately six original HCQI sets for RA and/or OA being identified (one for RA and OA, two for OA and three for RA). The number of HCQI ranged from 7 to 27, with the majority being process indicators. No conflicting indicators between the HCQI sets for one condition were seen. Concerning the quality of the developmental process, all six sets lacked patient involvement. Only a limited number of HCQI sets for the management of OA and RA are available, mainly including process indicators. The developmental process was methodologically suboptimal in all cases. As improvement of health care quality is an ongoing process, there is a need for development of HCQIs covering different aspects of health care quality (structure, process and outcome) and using appropriate methodology.

  6. A new approach to the identification of Landscape Quality Objectives (LQOs) as a set of indicators.

    Science.gov (United States)

    Sowińska-Świerkosz, Barbara Natalia; Chmielewski, Tadeusz J

    2016-12-15

    The objective of the paper is threefold: (1) to introduce Landscape Quality Objectives (LQOs) as a set of indicators; (2) to present a method of linking social and expert opinion in the process of the formulation of landscape indicators; and (3) to present a methodological framework for the identification of LQOs. The implementation of these goals adopted a six-stage procedure based on the use of landscape units: (1) GIS analysis; (2) classification; (3) social survey; (4) expert value judgement; (5) quality assessment; and (6) guidelines formulation. The essence of the research was the presentation of features that determine landscape quality according to public opinion as a set of indicators. The results showed that 80 such indicators were identified, of both a qualitative (49) and a quantitative character (31). Among the analysed units, 60% (18 objects) featured socially expected (and confirmed by experts) levels of landscape quality, and 20% (6 objects) required overall quality improvement in terms of both public and expert opinion. The adopted procedure provides a new tool for integrating social responsibility into environmental management. The advantage of the presented method is the possibility of its application in the territories of various European countries. It is flexible enough to be based on cartographic studies, landscape research methods, and environmental quality standards existing in a given country. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. A 2-1-1 research collaboration: participant accrual and service quality indicators.

    Science.gov (United States)

    Eddens, Katherine S; Alcaraz, Kassandra I; Kreuter, Matthew W; Rath, Suchitra; Greer, Regina

    2012-12-01

    In times of crises, 2-1-1 serves as a lifeline in many ways. These crises often cause a spike in call volume that can challenge 2-1-1's ability to meet its service quality standards. For researchers gathering data through 2-1-1s, a sudden increase in call volume might reduce accrual as 2-1-1 has less time to administer study protocols. Research activities imbedded in 2-1-1 systems may affect directly 2-1-1 service quality indicators. Using data from a 2-1-1 research collaboration, this paper examines the impact of crises on call volume to 2-1-1, how call volume affects research participant accrual through 2-1-1, and how research recruitment efforts affect 2-1-1 service quality indicators. t-tests were used to examine the effect of call volume on research participant accrual. Linear and logistic regressions were used to examine the effect of research participant accrual on 2-1-1 service quality indicators. Data were collected June 2010-December 2011; data were analyzed in 2012. Findings from this collaboration suggest that crises causing spikes in call volume adversely affect 2-1-1 service quality indicators as well as accrual of research participants. Administering a brief (2-3 minute) health risk assessment did not affect service quality negatively, but administering a longer (15-18 minute) survey had a modest adverse effect on these indicators. In 2-1-1 research collaborations, both partners need to understand the dynamic relationship among call volume, research accrual, and service quality and adjust expectations accordingly. If research goals include administering a longer survey, increased staffing of 2-1-1 call centers may be needed to avoid compromising service quality. Copyright © 2012 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  8. [Validation and adhesion to GESIDA quality indicators in patients with HIV infection].

    Science.gov (United States)

    Riera, Melchor; Esteban, Herminia; Suarez, Ignacio; Palacios, Rosario; Lozano, Fernando; Blanco, Jose R; Valencia, Eulalia; Ocampo, Antonio; Amador, Concha; Frontera, Guillem; vonWichmann-de Miguel, Miguel Angel

    2016-01-01

    The objective of the study is to validate the relevant GESIDA quality indicators for HIV infection, assessing the reliability, feasibility and adherence to them. The reliability was evaluated using the reproducibility of 6 indicators in peer review, with the second observer being an outsider. The feasibility and measurement of the level of adherence to the 22 indicators was conducted with annual fragmented retrospective collection of information from specific databases or the clinical charts of the nine participating hospitals. Reliability was very high, with interobserver agreement levels higher than 95% in 5 of the 6 indicators. The median time to achieve the indicators ranged between 5 and 600minutes, but could be achieved progressively from specific databases, enabling obtaining them automatically. As regards adherence to the indicators related with the initial evaluation of the patients, instructions and suitability of the guidelines for ART, adherence to ART, follow-up in clinics, and achieve an undetectable HIV by PCR at week 48 of the ART. Indicators of quality related to the prevention of opportunistic infections and control of comorbidities, the standards set were not achieved, and significant heterogeneity was observed between hospitals. The GESIDA quality indicators of HIV infection enabled the relevant indicators to be feasibly and reliably measured, and should be collected in all the units that care for patients with HIV infection. Copyright © 2015 Elsevier España, S.L.U. and Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.

  9. [Development of quality of care indicators to support chronic disease management].

    Science.gov (United States)

    Beaulieu, Marie-dominique; Pomey, Marie-pascale; Del Grande, Claudio; Côté, Brigitte; Tremblay, Éric; Ghorbel, Monia; Hua, Phuong

    2015-01-01

    This article presents the results of a project conducted by the Institut national d'excellence en santé et en services sociaux of Québec to develop quality of care indicators for the management of six chronic illnesses. Indicators were identified through literature searches and analysis of clinical practice guidelines (CPGs). Interdisciplinary expert panels assessed their validity and the strength of the evidence on which they were based. Representatives of patients (N = 19) and professionals (N = 29) were consulted on their relevance and acceptability. Indicators were categorized according to the Chronic Care Model (CCM). A total of 164 indicators were developed, 126 specific to the illnesses under study and 38 on processes and outcomes generic to the CCM. There was convergence between patients and professionals on the relevance of a majority of indicators. Professionals expressed concerns on the indicators measured by means of patient surveys that they considered to be too subjective. The importance given to CPGs as the main source of indicators resulted in a great number of indicators of the technical quality ofcare. Using the CCM contributed to a broader perspective of quality. The consultation process identified some of the concerns of professionals about indicator measurement, thusguidingfuture implementation initiatives.

  10. Cone beam computed tomography in implant dentistry: a systematic review focusing on guidelines, indications, and radiation dose risks.

    Science.gov (United States)

    Bornstein, Michael M; Scarfe, William C; Vaughn, Vida M; Jacobs, Reinhilde

    2014-01-01

    The aim of the paper is to identify, review, analyze, and summarize available evidence in three areas on the use of cross-sectional imaging, specifically maxillofacial cone beam computed tomography (CBCT) in pre- and postoperative dental implant therapy: (1) Available clinical use guidelines, (2) indications and contraindications for use, and (3) assessment of associated radiation dose risk. Three focused questions were developed to address the aims. A systematic literature review was performed using a PICO-based search strategy based on MeSH key words specific to each focused question of English-language publications indexed in the MEDLINE database retrospectively from October 31, 2012. These results were supplemented by a hand search and gray literature search. Twelve publications were identified providing guidelines for the use of cross-sectional radiography, particularly CBCT imaging, for the pre- and/or postoperative assessment of potential dental implant sites. The publications discovered by the PICO strategy (43 articles), hand (12), and gray literature searches (1) for the second focus question regarding indications and contraindications for CBCT use in implant dentistry were either cohort or case-controlled studies. For the third question on the assessment of associated radiation dose risk, a total of 22 articles were included. Publication characteristics and themes were summarized in tabular format. The reported indications for CBCT use in implant dentistry vary from preoperative analysis regarding specific anatomic considerations, site development using grafts, and computer-assisted treatment planning to postoperative evaluation focusing on complications due to damage of neurovascular structures. Effective doses for different CBCT devices exhibit a wide range with the lowest dose being almost 100 times less than the highest dose. Significant dose reduction can be achieved by adjusting operating parameters, including exposure factors and reducing the

  11. Competition and quality indicators in the health care sector: empirical evidence from the Dutch hospital sector.

    Science.gov (United States)

    Croes, R R; Krabbe-Alkemade, Y J F M; Mikkers, M C

    2018-01-01

    There is much debate about the effect of competition in healthcare and especially the effect of competition on the quality of healthcare, although empirical evidence on this subject is mixed. The Netherlands provides an interesting case in this debate. The Dutch system could be characterized as a system involving managed competition and mandatory healthcare insurance. Information about the quality of care provided by hospitals has been publicly available since 2008. In this paper, we evaluate the relationship between quality scores for three diagnosis groups and the market power indicators of hospitals. We estimate the impact of competition on quality in an environment of liberalized pricing. For this research, we used unique price and production data relating to three diagnosis groups (cataract, adenoid and tonsils, bladder tumor) produced by Dutch hospitals in the period 2008-2011. We also used the quality indicators relating to these diagnosis groups. We reveal a negative relationship between market share and quality score for two of the three diagnosis groups studied, meaning that hospitals in competitive markets have better quality scores than those in concentrated markets. We therefore conclude that more competition is associated with higher quality scores.

  12. Quality assurance in proton beam therapy using a plastic scintillator and a commercially available digital camera.

    Science.gov (United States)

    Almurayshid, Mansour; Helo, Yusuf; Kacperek, Andrzej; Griffiths, Jennifer; Hebden, Jem; Gibson, Adam

    2017-09-01

    In this article, we evaluate a plastic scintillation detector system for quality assurance in proton therapy using a BC-408 plastic scintillator, a commercial camera, and a computer. The basic characteristics of the system were assessed in a series of proton irradiations. The reproducibility and response to changes of dose, dose-rate, and proton energy were determined. Photographs of the scintillation light distributions were acquired, and compared with Geant4 Monte Carlo simulations and with depth-dose curves measured with an ionization chamber. A quenching effect was observed at the Bragg peak of the 60 MeV proton beam where less light was produced than expected. We developed an approach using Birks equation to correct for this quenching. We simulated the linear energy transfer (LET) as a function of depth in Geant4 and found Birks constant by comparing the calculated LET and measured scintillation light distribution. We then used the derived value of Birks constant to correct the measured scintillation light distribution for quenching using Geant4. The corrected light output from the scintillator increased linearly with dose. The system is stable and offers short-term reproducibility to within 0.80%. No dose rate dependency was observed in this work. This approach offers an effective way to correct for quenching, and could provide a method for rapid, convenient, routine quality assurance for clinical proton beams. Furthermore, the system has the advantage of providing 2D visualization of individual radiation fields, with potential application for quality assurance of complex, time-varying fields. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  13. A Critical Assessment of the Quality and Validity of Composite Indicators of Innovation

    Energy Technology Data Exchange (ETDEWEB)

    Vértesy, D.

    2016-07-01

    While it is generally accepted that monitoring innovation system performance requires a set of indicators, there is a constant debate on whether and how composite indices can be used to summarize them. This paper enters this discussion by assessing the validity and quality of the most commonly used composite indicators of innovation. In our framework, the validity of an index relates to the link between component indicators or aggregates and to the aspect(s) of national systems of innovation they seek to measure, while the quality of an indicator relates to its statistical properties. To better understand validity, we discuss how the evolution of the national system of innovation concept and its use in policy has shifted demand from an advocacy to more analytical functions of composite indicators of innovation.We next examine selected composite indicators of innovation (the WIPO-INSEAD’s Global Innovation Indicator, the Summary Innovation Index and Innovation Output Indicator of the European Commission and the Fraunhofer Innovation Index) in different contexts of external and internal validity and conduct global sensitivity analyses on them. Our policy-relevant findings highlight the need for analytically stronger composites of a more limited set of indicators.We also found significant quality differences across the indices, as some included components which explain little or none of the variance in composite scores, and were more sensitive to modeling choices. The indices studied differed in how validly they represented various innovation system functions and types of innovation, and showed information relevant for a broader or a more limited set of stakeholders. We argue that further development of innovation indicators should put more emphasis on identifying tradeoffs within innovation policy, and unintended consequences of innovative activities. (Author)

  14. [Implementation of nine quality indicators in a hospital emergency clinical laboratory].

    Science.gov (United States)

    Guzmán D, Ana María; Sánchez P, Tomás; DE LA Barra D, Ricardo; Madrid Q, Angélica; Quiroga G, Teresa

    2011-02-01

    Quality indicators are tools used to monitor specific activities within a process and improve it. In the area of clinical laboratories, the National Accreditation Standards for Providers of Health and the ISO 15189 standard recommend the implementation of indicators that monitor the test cycle with emphasis on those that contribute to a safer health care. To describe the implementation of nine indicators in a hospital clinical laboratory and their measurement during one year. The indicators implemented and measured were four of the pre-analytical phase (number of rejected samples, times of transport, blood culture contamination and blood cultures inoculated with adequate blood volumes), two of the analytical phase (coherence of Gram stains of blood culture with microorganism cultured and correct results in external quality control surveys) and three of the post-analytical phase (compliance with order to report lapse goals, corrected reports and alert values report). Two indicators of pre-analytical phase did not meet the per determined targets: number of rejected samples and blood cultures inoculated with adequate blood volume. All indicators of the analytical and post analytical phases were within the pre-determined targets. Coordinated work should be initiated especially with the nursing service to correct the two indicators that did not meet the target. The incorporation of quality indicators to monitor critical processes within the laboratory was undoubtedly an opportunity to identify areas for improvement.

  15. Utility of the computed tomography indices on cone beam computed tomography images in the diagnosis of osteoporosis in women

    International Nuclear Information System (INIS)

    Koh, Kwang Joon; Kim, Kyung A

    2011-01-01

    This study evaluated the potential use of the computed tomography indices (CTI) on cone beam CT (CBCT) images for an assessment of the bone mineral density (BMD) in postmenopausal osteoporotic women. Twenty-one postmenopausal osteoporotic women and 21 postmenopausal healthy women were enrolled as the subjects. The BMD of the lumbar vertebrae and femur were calculated by dual energy X-ray absorptiometry (DXA) using a DXA scanner. The CBCT images were obtained from the unilateral mental foramen region using a PSR-9000N Dental CT system. The axial, sagittal, and coronal images were reconstructed from the block images using OnDemend3D. The new term 'CTI' on CBCT images was proposed. The relationship between the CT measurements and BMDs were assessed and the intra-observer agreement was determined. There were significant differences between the normal and osteoporotic groups in the computed tomography mandibular index superior (CTI(S)), computed tomography mandibular index inferior (CTI(I)), and computed tomography cortical index (CTCI). On the other hand, there was no difference between the groups in the computed tomography mental index (CTMI: inferior cortical width). CTI(S), CTI(I), and CTCI on the CBCT images can be used to assess the osteoporotic women.

  16. Utility of the computed tomography indices on cone beam computed tomography images in the diagnosis of osteoporosis in women

    Energy Technology Data Exchange (ETDEWEB)

    Koh, Kwang Joon; Kim, Kyung A [School of Dentistry, Chonbuk National University, Jeonju (Korea, Republic of)

    2011-09-15

    This study evaluated the potential use of the computed tomography indices (CTI) on cone beam CT (CBCT) images for an assessment of the bone mineral density (BMD) in postmenopausal osteoporotic women. Twenty-one postmenopausal osteoporotic women and 21 postmenopausal healthy women were enrolled as the subjects. The BMD of the lumbar vertebrae and femur were calculated by dual energy X-ray absorptiometry (DXA) using a DXA scanner. The CBCT images were obtained from the unilateral mental foramen region using a PSR-9000N Dental CT system. The axial, sagittal, and coronal images were reconstructed from the block images using OnDemend3D. The new term 'CTI' on CBCT images was proposed. The relationship between the CT measurements and BMDs were assessed and the intra-observer agreement was determined. There were significant differences between the normal and osteoporotic groups in the computed tomography mandibular index superior (CTI(S)), computed tomography mandibular index inferior (CTI(I)), and computed tomography cortical index (CTCI). On the other hand, there was no difference between the groups in the computed tomography mental index (CTMI: inferior cortical width). CTI(S), CTI(I), and CTCI on the CBCT images can be used to assess the osteoporotic women.

  17. Indices of quality surface water bodies in the planning of water resources

    OpenAIRE

    Rodríguez-Miranda, Juan Pablo; Serna Mosquera, Jorge Antonio; Sánchez Céspedes, Juan Manuel

    2016-01-01

    This paper considers a review of the literature major and significant methods of quality indices of water applied in surface water bodies, used and proposed for assessing the significance of parameters of water quality in the assessment of surface water currents and they are usually used in making decisions for intervention and strategic prevention measures for those responsible for the conservation and preservation of watersheds where these water bodies belong. An exploratory methodology was...

  18. Evaluation of soil quality indicators in paddy soils under different crop rotation systems

    Science.gov (United States)

    Nadimi-Goki, Mandana; Bini, Claudio; Haefele, Stephan; Abooei, Monireh

    2013-04-01

    Evaluation of soil quality indicators in paddy soils under different crop rotation systems Soil quality, by definition, reflects the capacity to sustain plant and animal productivity, maintain or enhance water and air quality, and promote plant and animal health. Soil quality assessment is an essential issue in soil management for agriculture and natural resource protection. This study was conducted to detect the effects of four crop rotation systems (rice-rice-rice, soya-rice-rice, fallow-rice and pea-soya-rice) on soil quality indicators (soil moisture, porosity, bulk density, water-filled pore space, pH, extractable P, CEC, OC, OM, microbial respiration, active carbon) in paddy soils of Verona area, Northern Italy. Four adjacent plots which managed almost similarly, over five years were selected. Surface soil samples were collected from each four rotation systems in four times, during growing season. Each soil sample was a composite of sub-samples taken from 3 points within 350 m2 of agricultural land. A total of 48 samples were air-dried and passed through 2mm sieve, for some chemical, biological, and physical measurements. Statistical analysis was done using SPSS. Statistical results revealed that frequency distribution of most data was normal. The lowest CV% was related to pH. Analysis of variance (ANOVA) and comparison test showed that there are significant differences in soil quality indicators among crop rotation systems and sampling times. Results of multivariable regression analysis revealed that soil respiration had positively correlation coefficient with soil organic matter, soil moisture and cation exchange capacity. Overall results indicated that the rice rotation with legumes such as bean and soybean improved soil quality over a long time in comparison to rice-fallow rotation, and this is reflected in rice yield. Keywords: Soil quality, Crop Rotation System, Paddy Soils, Italy

  19. Chemical, biochemical and microbiological indicators to assess soil quality in temperate agro-ecosystems

    OpenAIRE

    Giacometti, Caterina

    2013-01-01

    Soil is a critically important component of the earth’s biosphere. Developing agricultural production systems able to conserve soil quality is essential to guarantee the current and future capacity of soil to provide goods and services. This study investigates the potential of microbial and biochemical parameters to be used as early and sensitive soil quality indicators. Their ability to differentiate plots under contrasting fertilization regimes is evaluated based also on their sensitivi...

  20. STUDY ON WATER QUALITY INDICATORS AT TAIA TREATMENT PLANT HUNDEDOARA COUNTY

    Directory of Open Access Journals (Sweden)

    Ramona Violeta CAZALBAŞU

    2017-05-01

    Full Text Available Water is consumed in its natural form or in a processed one. It is a well-known fact that enterprises, institutions, energy and agriculture consume it as processed water whereas the population consumes it as drinking water or wastewater. This paper presents the study of water quality indicators from the treatment plant Taia in Hunedoara County. The following quality indicators were determined: turbidity, hardness, alkalinity, chlorine oxide and organic substances. The determined quality indicators revealed that they fall within the limits set by legislation, with some exceptions. In each step of purification of organic substances there has been a continual reduction, this being carried out both biologically because of the biomass deposited on sand grains in the filter bed as well as especially during the oxidation step with active chlorine

  1. The variability of surface water quality indicators in relation to watercourse typology, Czech Republic.

    Science.gov (United States)

    Langhammer, Jakub; Hartvich, Filip; Mattas, Daniel; Rödlová, Sylva; Zbořil, Aleš

    2012-06-01

    This paper examines the relationships between watercourse typology and selected indicators of long-term surface water quality for rivers in the Czech Republic. The parameters used to define watercourse typology are in accord with the Water Framework Directive 2000/60/EC outlined by the European Commission. The relationships were tested using descriptive and multivariate statistical analysis, namely cluster analysis and canonical correspondence analysis. It was found that only some of the typological parameters have a close association with indicators of surface water quality. Specifically, the parameters of altitude and geology show clear relationships with pH, calcium content, and the saprobity index of macroinvertebrates. Conversely, parameters that are strongly influenced by anthropogenic pollution show weak relationships with indicators of surface water quality. These depend instead on the presence of pollution sources rather than on natural environmental conditions.

  2. Simulation and experiment studies of aberration effects on the measurement of laser beam quality factor (M2)

    Science.gov (United States)

    Meng, Lingqiang; Huang, Zheqiang; Han, Zhigang; Shen, Hua; Zhu, Rihong

    2018-01-01

    In the measurement system of beam quality factor, M2, wave-front and intensity aberrations caused by optical elements, thermal effects, residual pump light, etc., influence the measurement results. The influence was analyzed using the angular spectrum and the finite element methods. Simulation of the impact of different aberrations, thermal effects and residual pump light on the measurement of the M2 is provided. The M2 of a high-power fiber laser is measured by a beam quality analyzer when the laser transmits through a high absorption red glass with different output power. The results from the experiment and the simulation have good consistency. The simulation and experiment results can be applied for the designs of high-power laser, laser beam quality measurement, and laser-launching systems.

  3. TLD Postal service for quality audits of beams of Co-60 in reference conditions in Cuba

    International Nuclear Information System (INIS)

    Gutierrez L, S.; Walwyn S, G.; Alonso V, G.

    2006-01-01

    Purpose: To describe the methodology and experience of the Secondary Laboratory of Dosimetric Calibration of Cuba in the establishment of the TLD Postal Service for quality audits of beams of Co-60 in reference conditions. Materials and methods: Through the Coordinated Project of Research (Contract 10794) its was bought 200 solid thermoluminescent detectors of LiF: Mg, Ti (TLD-100) in micro bars form with dimensions of 6 x 1 x 1 mm and of the JR 1152F type manufactured in China. All these detectors were identified individually with a serial number on one of its faces, using a graphite fine sheet. Those detectors for its irradiation are introduced in cylindrical plastic capsules developed and used by the International Atomic Energy Agency (IAEA) in the Audit Postal Service of Dose IAEA/WHO, the capsules have one cavity equal to 3 mm for that is necessary to recover this cavity with a fine plastic tube so that the detectors remain immobile during the irradiation. The method used to determine the individual sensitivity of the thermoluminescent detectors is: to irradiate a detectors group (100 micro bars) 4 times in those same geometric conditions, with the same irradiation history and reading, then it is determine for each detector a sensitivity factor equal to the average of those readings obtained for the 4 irradiation cycles for each i detector among the average of all the reading values obtained during the 4 cycles. The thermoluminescent signal is obtained with a Harshaw 2000C/B reader manual. Results: The satisfactory results obtained in the verification of the calibration of the TLD system, using the reference irradiation service of the Seibersdorf Dosimetry Laboratory of the IAEA in three different years are shown. The results of the audits carried out to the different radiotherapy services of the country in different years are also presented. Conclusions: The experience with the detectors acquired in the project demonstrates that with an appropriate

  4. Quality indicators in headache care: an implementation study in six Italian specialist-care centres.

    Science.gov (United States)

    Pellesi, L; Benemei, S; Favoni, V; Lupi, C; Mampreso, E; Negro, A; Paolucci, M; Steiner, T J; Ulivi, M; Cevoli, S; Guerzoni, S

    2017-12-01

    Headache disorders are highly prevalent, and have a substantial and negative impact on health worldwide. They are largely treatable, but differences in structure, objectives, organization and delivery affect the quality of headache care. In order to recognize and remedy deficiencies in care, the Global Campaign against Headache, in collaboration with the European Headache Federation, recently developed a set of quality indicators for headache services. These require further assessment to demonstrate fitness for purpose. This is their first implementation to evaluate quality in headache care as a multicentre national study. Between September and December 2016, we applied the quality indicators in six Italian specialist headache centres (Bologna, Firenze, Modena, Padova, Roma Campus Bio-Medico and Roma Sapienza). We used five previously developed assessment instruments, translated into Italian according to Lifting The Burden's translation protocol for hybrid documents. We took data from 360 consecutive patients (60 per centre) by questionnaire and from their medical records, and by different questionnaires from their health-care providers (HCPs), including physicians, nurses, psychologists and nursing assistants. The findings, comparable between centres, confirmed the feasibility and practicability of using the quality indicators in Italian specialist headache centres. The questionnaires were easily understood by HCPs and patients, and were not unduly time-consuming. Diagnoses were almost all (> 97%) according to ICHD criteria, and routinely (100%) reviewed during follow-up. Diagnostic diaries were regularly used by 96% of physicians. Referral pathways from primary to specialist care existed in five of the six clinics, as did urgent referral pathways. Instruments to assess disability and quality of life were not used regularly, a deficiency that needs to be addressed. This Italy-wide survey confirmed in six specialist centres that the headache service quality

  5. High quality proton beams from hybrid integrated laser-driven ion acceleration systems

    Science.gov (United States)

    Sinigardi, Stefano; Turchetti, Giorgio; Rossi, Francesco; Londrillo, Pasquale; Giove, Dario; De Martinis, Carlo; Bolton, Paul R.

    2014-03-01

    We consider a hybrid acceleration scheme for protons where the laser generated beam is selected in energy and angle and injected into a compact linac, which raises the energy from 30 to 60 MeV. The laser acceleration regime is TNSA and the energy spectrum is determined by the cutoff energy and proton temperature. The dependence of the spectrum on the target properties and the incidence angle is investigated with 2D PIC simulations. We base our work on widely available technologies and on laser with a short pulse, having in mind a facility whose cost is approximately 15 M €. Using a recent experiment as the reference, we choose the laser pulse and target so that the energy spectrum obtained from the 3D PIC simulation is close to the one observed, whose cutoff energy was estimated to be over 50 MeV. Laser accelerated protons in the TNSA regime have wide energy spectrum and broad divergence. In this paper we compare three transport lines, designed to perform energy selection and beam collimation. They are based on a solenoid, a quadruplet of permanent magnetic quadrupoles and a chicane. To increase the maximum available energy, which is actually seen as an upper limit due to laser properties and available targets, we propose to inject protons into a small linac for post-acceleration. The number of selected and injected protons is the highest with the solenoid and lower by one and two orders of magnitude with the quadrupoles and the chicane respectively. Even though only the solenoid enables achieving to reach a final intensity at the threshold required for therapy with the highest beam quality, the other systems will be very likely used in the first experiments. Realistic start-to-end simulations, as the ones reported here, are relevant for the design of such experiments.

  6. High quality proton beams from hybrid integrated laser-driven ion acceleration systems

    International Nuclear Information System (INIS)

    Sinigardi, Stefano; Turchetti, Giorgio; Rossi, Francesco; Londrillo, Pasquale; Giove, Dario; De Martinis, Carlo; Bolton, Paul R.

    2014-01-01

    We consider a hybrid acceleration scheme for protons where the laser generated beam is selected in energy and angle and injected into a compact linac, which raises the energy from 30 to 60 MeV. The laser acceleration regime is TNSA and the energy spectrum is determined by the cutoff energy and proton temperature. The dependence of the spectrum on the target properties and the incidence angle is investigated with 2D PIC simulations. We base our work on widely available technologies and on laser with a short pulse, having in mind a facility whose cost is approximately 15M€. Using a recent experiment as the reference, we choose the laser pulse and target so that the energy spectrum obtained from the 3D PIC simulation is close to the one observed, whose cutoff energy was estimated to be over 50 MeV. Laser accelerated protons in the TNSA regime have wide energy spectrum and broad divergence. In this paper we compare three transport lines, designed to perform energy selection and beam collimation. They are based on a solenoid, a quadruplet of permanent magnetic quadrupoles and a chicane. To increase the maximum available energy, which is actually seen as an upper limit due to laser properties and available targets, we propose to inject protons into a small linac for post-acceleration. The number of selected and injected protons is the highest with the solenoid and lower by one and two orders of magnitude with the quadrupoles and the chicane respectively. Even though only the solenoid enables achieving to reach a final intensity at the threshold required for therapy with the highest beam quality, the other systems will be very likely used in the first experiments. Realistic start-to-end simulations, as the ones reported here, are relevant for the design of such experiments

  7. Quality control methodology and implementation of X-radiation standards beams, mammography level, following the standard IEC 61267

    International Nuclear Information System (INIS)

    Correa, Eduardo de Lima

    2010-01-01

    In this work it was developed and applied a quality control program of the X radiation system (160 kV, constant potential, target of tungsten) of the Calibration Laboratory of IPEN(LCI) in the energy range relative to mammography beams (from 25 kV to 35 kV). The X radiation standards beams, level mammography, using molybdenum and aluminum as additional filtration, were established after the application of this quality control program following national and international recommendations. The reference ionization chamber has traceability to PTB and was regularly submitted to quality control tests for evaluation and analysis of its performance. The radiation qualities emerging from the X-radiation assembly (RQR-M), based on a phantom made up of an aluminum added filter (RQA-M), narrow beam condition (RQN-M) and broad beam condition (RQB-M), following the recommendations of the international standard IEC 61267 (2005) and the IAEA code of practice, TRS 457 (2007) were established. For the implantation of RQN-M and RQB-M radiation qualities, two mammography phantoms were developed. The half-value layers found are those presented by the German primary laboratory PTB, and varied from 0.35 to 1.21 mm Al. The air kerma rates were obtained for all the 15 implanted qualities. (author)

  8. "Strangers in the ER": Quality indicators and third party interference in Dutch emergency care.

    Science.gov (United States)

    Moes, Floortje B; Houwaart, Eddy S; Delnoij, Diana M J; Horstman, Klasien

    2018-03-06

    This paper examines a remarkable dispute between Dutch insurers, hospitals, doctors, and patients about a set of quality indicators. In 2013, private insurers planned to drastically reform Dutch emergency care using quality indicators they had formulated drawing from clinical guidelines, RCTs, and systematic reviews. Insurers' plans caused much debate in the field of emergency care. As quality indicators have come to play a more central role in health care governance, the questions what constitutes good evidence for them, how they ought to be used, and who controls them have become politically and morally charged. This paper is a case study of how a Dutch public knowledge institution, the National Health Care Institute, intervened in this dispute and how they addressed these questions. We conducted ethnographic research into the knowledge work of the National Health Care Institute. Research entailed document analysis, participant observation, in-depth conversations, and formal interviews with 5 key-informants. The National Health Care Institute problematized not only the evidence supporting insurers' indicators, but also-and especially-the scope, purpose, and use of the indicators. Our analysis shows the institute's struggle to reconcile the technical rationality of quality indicators with their social and political implications in practice. The institute deconstructed quality indicators as national standards and, instead, promoted the use of indicators in dialogue with stakeholders and their local and contextual knowledge. Even if quality indicators are based on scientific evidence, they are not axiomatically good or useful. Both proponents and critics of Evidence-based Medicine always feared uncritical use of evidence by third parties. For non-medical parties who have no access to primary care processes, the type of standardized knowledge professed by Evidence-based Medicine provides the easiest way to gain insights into "what works" in clinical practice. This

  9. Paper 3: EUROCAT data quality indicators for population-based registries of congenital anomalies

    DEFF Research Database (Denmark)

    Loane, Maria; Dolk, Helen; Garne, Ester

    2011-01-01

    for fetal anomaly. EUROCAT's policy is to strive for high-quality data, while ensuring consistency and transparency across all member registries. A set of 30 data quality indicators (DQIs) was developed to assess five key elements of data quality: completeness of case ascertainment, accuracy of diagnosis...... for 2004-2008. This information is also available on the EUROCAT website for previous years. The EUROCAT DQIs allow registries to evaluate their performance in relation to other registries and allows appropriate interpretations to be made of the data collected. The DQIs provide direction for improving data...

  10. Use of biological indicators to assess water quality of the Ul River (Portugal).

    Science.gov (United States)

    Resende, Paula Cristina; Resende, Paulo; Pardal, Miguel; Almeida, Salomé; Azeiteiro, Ulisses

    2010-11-01

    Diatoms and macroinvertebrates have been extensively used as water quality indicators in Europe for the last two decades. In Portugal, the use of biological indicators to assess water quality in rivers has increased greatly. The aim of this work was to assess the water quality and ecological status of the Ul River in order to evaluate its ability for the establishment of a fluvial beach, using periphytic diatoms and macroinvertebrates as indicators. Four sites were selected along the Ul River. At each site, biological, physical, and chemical parameters were investigated. Epilithic diatoms and macroinvertebrates were sampled. The Specific Polluosensitivity Index and the Biological Diatom Index were applied to diatom data, while for macroinvertebrates, the Iberian Biological Monitoring Working Party (IBMWP) was used. According to the results obtained, it was possible to conclude that up to now, this river does not possess the ideal conditions for the establishment of a fluvial beach. We concluded that epilithic diatoms and macroinvertebrates provided consistent information on water quality assessment and can be used as biological indicators of the water quality in Ul River.

  11. Influence of the Integral Quality Monitor transmission detector on high energy photon beams. A multi-centre study

    Energy Technology Data Exchange (ETDEWEB)

    Casar, Bozidar [Institute of Oncology, Ljubljana (Slovenia). Dept. of Radiation Physics; Pasler, Marlies [Lake Constance Radiation Oncology Center, Singen and Friedrichshafen (Germany); Wegener, Sonja [Wuerzburg Univ. (Germany). Dept. of Radiation Oncology; and others

    2017-10-01

    The influence of the Integral Quality Monitor (IQM) transmission detector on photon beam properties was evaluated in a preclinical phase, using data from nine participating centres: (i) the change of beam quality (beam hardening), (ii) the influence on surface dose, and (iii) the attenuation of the IQM detector. For 6 different nominal photon energies (4 standard, 2 FFF) and square field sizes from 1 x 1 cm{sup 2} to 20 x 20 cm{sup 2}, the effect of IQM on beam quality was assessed from the PDD{sub 20,10} values obtained from the percentage dose depth (PDD) curves, measured with and without IQM in the beam path. The change in surface dose with/without IQM was assessed for all available energies and field sizes from 4 x 4 cm{sup 2} to 20 x 20 cm{sup 2}. The transmission factor was calculated by means of measured absorbed dose at 10 cm depth for all available energies and field sizes. (i) A small (0.11-0.53%) yet statistically significant beam hardening effect was observed, depending on photon beam energy. (ii) The increase in surface dose correlated with field size (p < 0.01) for all photon energies except for 18 MV. The change in surface dose was smaller than 3.3% in all cases except for the 20 x 20 cm{sup 2} field and 10 MV FFF beam, where it reached 8.1%. (iii) For standard beams, transmission of the IQM showed a weak dependence on the field size, and a pronounced dependence on the beam energy (0.9412 for 6 MV to 0.9578 for 18 MV and 0.9440 for 6 MV FFF; 0.9533 for 10 MV FFF). The effects of the IQM detector on photon beam properties were found to be small yet statistically significant. The magnitudes of changes which were found justify treating IQM either as tray factors within the treatment planning system (TPS) for a particular energy or alternatively as modified outputs for specific beam energy of linear accelerators, which eases the introduction of the IQM into clinical practice.

  12. Sound quality indicators for urban places in Paris cross-validated by Milan data.

    Science.gov (United States)

    Ricciardi, Paola; Delaitre, Pauline; Lavandier, Catherine; Torchia, Francesca; Aumond, Pierre

    2015-10-01

    A specific smartphone application was developed to collect perceptive and acoustic data in Paris. About 3400 questionnaires were analyzed, regarding the global sound environment characterization, the perceived loudness of some emergent sources and the presence time ratio of sources that do not emerge from the background. Sound pressure level was recorded each second from the mobile phone's microphone during a 10-min period. The aim of this study is to propose indicators of urban sound quality based on linear regressions with perceptive variables. A cross validation of the quality models extracted from Paris data was carried out by conducting the same survey in Milan. The proposed sound quality general model is correlated with the real perceived sound quality (72%). Another model without visual amenity and familiarity is 58% correlated with perceived sound quality. In order to improve the sound quality indicator, a site classification was performed by Kohonen's Artificial Neural Network algorithm, and seven specific class models were developed. These specific models attribute more importance on source events and are slightly closer to the individual data than the global model. In general, the Parisian models underestimate the sound quality of Milan environments assessed by Italian people.

  13. Quality indicators for the analysis of communication in an online course

    Directory of Open Access Journals (Sweden)

    Antonella Pezzotti

    2012-08-01

    Full Text Available This study describes the development and validation of quality indicators for analyzing forums interactions in an online course in biology teaching. The aim is to evaluate the quality of communication so as to strengthen the tutor’s role and help students learn fundamental biology concepts while enhancing their collaboration competencies. The indicators are used to analyze cognitive, metacognitive and relational aspects, drawing on a content analysis methodology. The model appears to have a wide range of possible applications in other online courses.

  14. Concordance and robustness of quality indicator sets for hospitals: an analysis of routine data.

    Science.gov (United States)

    Stausberg, Jürgen; Halim, Axel; Färber, Robert

    2011-05-18

    Hospitals are increasingly being evaluated with respect to the quality of provided care. In this setting, several indicator sets compete with one another for the assessment of effectiveness and safety. However, there have been few comparative investigations covering different sets. The objective of this study was to answer three questions: How concordant are different indicator sets on a hospital level? What is the effect of applying different reference values? How stable are the positions of a hospital ranking? Routine data were made available to three companies offering the Patient Safety Indicators, an indicator set from the HELIOS Hospital Group, and measurements based on Disease Staging™. Ten hospitals from North Rhine-Westphalia, comprising a total of 151,960 inpatients in 2006, volunteered to participate in this study. The companies provided standard quality reports for the ten hospitals. Composite measures were defined for strengths and weaknesses. In addition to the different indicator sets, different reference values for one set allowed the construction of several comparison groups. Concordance and robustness were analyzed using the non-parametric correlation coefficient and Kendall's W. Indicator sets differing only in the reference values of the indicators showed significant correlations in most of the pairs with respect to weaknesses (maximum r = 0.927, CI 0.714-0.983, p definition of quality, independent of their focus on patient safety, mortality, or length of stay. However, for most of the hospitals, changing the indicator set or the reference value resulted in a shift from the superior to the inferior half of the group or vice versa. Thus, while taken together the indicator sets offer the hospitals complementary pictures of their quality, on an individual basis they do not establish a reliable ranking.

  15. Benthic Diatom Based Indices for Water Quality Assessment in Two Subtropical Streams.

    Science.gov (United States)

    Tan, Xiang; Zhang, Quanfa; Burford, Michele A; Sheldon, Fran; Bunn, Stuart E

    2017-01-01

    Benthic diatoms have been universally used as indicators to assess water quality in lotic ecosystems. However, most diatom-based indices developed in Europe have not been widely used or tested in other continents such as Asia or Oceania. This study compared the performance of 14 widely-applied diatom indices in assessing ecological conditions in subtropical streams in South East Queensland (SEQ) in Australia and in the upper Han River in China. Most water quality variables in the upper Han River including dissolved organic carbon (DOC), total nitrogen (TN), and soluble reactive phosphorus (SRP) had strong relationships with at least one diatom index, with the exception of IDAP (Index Diatom Artois-Picardie), and TDI (Trophic Diatom Index). However, in SEQ, most of the environmental variables including DOC, ammonia nitrogen (NH 4 -N), TN, SRP, and electrical conductivity (EC) showed no significant relationships with diatom indices, and the DI-CH (Swiss Diatom Index) and WAT (Watanabe's Index) were unrelated to any of the variables examined. Only pH and nitrite or nitrate nitrogen (NO X -N) were significant predictors of several diatom indices in SEQ, especially TID (Rott trophic index). In the upper Han River, much of the spatial variation in most diatom indices was explained by proximate determinants alone, including EC, DOC, dissolved oxygen (DO) or SRP, or a combination of ultimate (canopy, forest) and proximate factors ( R 2 in most models> 0.75). Most diatom indices performed as predicted in the upper Han River where nutrient and organic matter pollution was relatively high, and variation in pH low. However, the indices performed poorly in SEQ where the water quality gradient was low and instead most responded to spatial variation in pH. This finding serves as a caution to the application of diatom indices in river basins that fall outside of the range of water quality values of the systems in which they originally developed.

  16. Application of water quality indices and analysis of the surface water quality monitoring network in semiarid North-Central Chile.

    Science.gov (United States)

    Espejo, Lesly; Kretschmer, Nicole; Oyarzún, Jorge; Meza, Francisco; Núñez, Jorge; Maturana, Hugo; Soto, Guido; Oyarzo, Paula; Garrido, Marcela; Suckel, Felipe; Amezaga, Jaime; Oyarzún, Ricardo

    2012-09-01

    Surface water quality has increasing importance worldwide and is particularly relevant in the semiarid North-Central Chile, where agriculture and mining activities are imposing heavy pressure on limited water resources. The current study presents the application of a water quality index in four watersheds of the 29°-33°S realm for the period 1999-2008, based on the Canadian Council of Ministers for the Environment approach and the Chilean regulation for irrigation water quality. In addition, two modifications to the index are tested and a comprehensive characterization of the existing monitoring network is performed through cluster analysis. The basins studied show fairly good water quality in the overall, specially the Limarí basin. On the other hand, the lower index values were obtained for the headwaters of Elqui, associated with the El Indio mining district. The first modification of the indicator (i.e., to consider parameters differentially according to their effect on human health or the environment) did not produce major differences with respect to the original index, given the generally good water quality. The second modification (i.e., to consider as threshold values the more restrictive figures derived from a set of regulations) yielded important differences in the indicator values. Finally, an adequate characterization of the monitoring network was obtained. The results presented spatial coherence and the information can be used as a basis for the optimization of the monitoring network if required.

  17. Concordance and robustness of quality indicator sets for hospitals: an analysis of routine data

    Directory of Open Access Journals (Sweden)

    Färber Robert

    2011-05-01

    Full Text Available Abstract Background Hospitals are increasingly being evaluated with respect to the quality of provided care. In this setting, several indicator sets compete with one another for the assessment of effectiveness and safety. However, there have been few comparative investigations covering different sets. The objective of this study was to answer three questions: How concordant are different indicator sets on a hospital level? What is the effect of applying different reference values? How stable are the positions of a hospital ranking? Methods Routine data were made available to three companies offering the Patient Safety Indicators, an indicator set from the HELIOS Hospital Group, and measurements based on Disease Staging™. Ten hospitals from North Rhine-Westphalia, comprising a total of 151,960 inpatients in 2006, volunteered to participate in this study. The companies provided standard quality reports for the ten hospitals. Composite measures were defined for strengths and weaknesses. In addition to the different indicator sets, different reference values for one set allowed the construction of several comparison groups. Concordance and robustness were analyzed using the non-parametric correlation coefficient and Kendall's W. Results Indicator sets differing only in the reference values of the indicators showed significant correlations in most of the pairs with respect to weaknesses (maximum r = 0.927, CI 0.714-0.983, p Conclusions Our results reveal an unsettling lack of concordance in estimates of hospital performance when different quality indicator sets are used. These findings underline the lack of consensus regarding optimal validated measures for judging hospital quality. The indicator sets shared a common definition of quality, independent of their focus on patient safety, mortality, or length of stay. However, for most of the hospitals, changing the indicator set or the reference value resulted in a shift from the superior to the

  18. Quality control in cone-beam computed tomography (CBCT) EFOMP-ESTRO-IAEA protocol (summary report).

    Science.gov (United States)

    de Las Heras Gala, Hugo; Torresin, Alberto; Dasu, Alexandru; Rampado, Osvaldo; Delis, Harry; Hernández Girón, Irene; Theodorakou, Chrysoula; Andersson, Jonas; Holroyd, John; Nilsson, Mats; Edyvean, Sue; Gershan, Vesna; Hadid-Beurrier, Lama; Hoog, Christopher; Delpon, Gregory; Sancho Kolster, Ismael; Peterlin, Primož; Garayoa Roca, Julia; Caprile, Paola; Zervides, Costas

    2017-07-01

    The aim of the guideline presented in this article is to unify the test parameters for image quality evaluation and radiation output in all types of cone-beam computed tomography (CBCT) systems. The applications of CBCT spread over dental and interventional radiology, guided surgery and radiotherapy. The chosen tests provide the means to objectively evaluate the performance and monitor the constancy of the imaging chain. Experience from all involved associations has been collected to achieve a consensus that is rigorous and helpful for the practice. The guideline recommends to assess image quality in terms of uniformity, geometrical precision, voxel density values (or Hounsfield units where available), noise, low contrast resolution and spatial resolution measurements. These tests usually require the use of a phantom and evaluation software. Radiation output can be determined with a kerma-area product meter attached to the tube case. Alternatively, a solid state dosimeter attached to the flat panel and a simple geometric relationship can be used to calculate the dose to the isocentre. Summary tables including action levels and recommended frequencies for each test, as well as relevant references, are provided. If the radiation output or image quality deviates from expected values, or exceeds documented action levels for a given system, a more in depth system analysis (using conventional tests) and corrective maintenance work may be required. Copyright © 2017. Published by Elsevier Ltd.

  19. Bowtie filter and water calibration in the improvement of cone beam CT image quality

    International Nuclear Information System (INIS)

    Li Minghui; Dai Jianrong; Zhang Ke

    2010-01-01

    Objective: To evaluate the improvement of cone beam CT (CBCT) image quality by using bewtie filter (F 1 ) and water calibration. Methods: First the multi-level gain calibration of the detector panel with the method of Cal 2 calibration was performed, and the CT images of CATPHAN503 with F 0 and bowtie filter were collected, respectively. Then the detector panel using water calibration kit was calibrated, and images were acquired again. Finally, the change of image quality after using F 1 and (or) water calibration method was observed. The observed indexes included low contrast visibility, spatial uniformity, ring artifact, spatial resolution and geometric accuracy. Results: Comparing with the traditional combination of F 0 filter and Cal 2 calibration, the combination of bowtie filter F 1 and water calibration improves low contrast visibility by 13.71%, and spatial uniformity by 54. 42%. Water calibration removes ring artifacts effectively. However, none of them improves spatial resolution and geometric accuracy. Conclusions: The combination of F 1 and water calibration improves CBCT image quality effectively. This improvement is aid to the registration of CBCT images and localization images. (authors)

  20. Instrument Psychometrics: Parental Satisfaction and Quality Indicators of Perinatal Palliative Care.

    Science.gov (United States)

    Wool, Charlotte

    2015-10-01

    Despite a life-limiting fetal diagnosis, prenatal attachment often occurs in varying degrees resulting in role identification by an individual as a parent. Parents recognize quality care and report their satisfaction when interfacing with health care providers. The aim was to test an instrument measuring parental satisfaction and quality indicators with parents electing to continue a pregnancy after learning of a life-limiting fetal diagnosis. A cross sectional survey design gathered data using a computer-mediated platform. Subjects were parents (n=405) who opted to continue a pregnancy affected by a life-limiting diagnosis. Factor analysis using principal component analysis with Varimax rotation was used to validate the instrument, evaluate components, and summarize the explained variance achieved among quality indicator items. The Prenatal Scale was reduced to 37 items with a three-component solution explaining 66.19% of the variance and internal consistency reliability of 0.98. The Intrapartum Scale included 37 items with a four-component solution explaining 66.93% of the variance and a Cronbach α of 0.977. The Postnatal Scale was reduced to 44 items with a six-component solution explaining 67.48% of the variance. Internal consistency reliability was 0.975. The Parental Satisfaction and Quality Indicators of Perinatal Palliative Care Instrument is a valid and reliable measure for parent-reported quality care and satisfaction. Use of this instrument will enable clinicians and researchers to measure quality indicators and parental satisfaction. The instrument is useful for assessing, analyzing, and reporting data on quality for care delivered during the prenatal, intrapartum, and postnatal periods.

  1. Quality of 'Sharpblue' blueberries after electron beam irradiation

    International Nuclear Information System (INIS)

    Miller, W.R.; McDonald, R.E.; Smittle, B.J.

    1995-01-01

    Freshly harvested 'Sharpblue' blueberries (Vaccinium spp.), a hybrid of complex parentage (Sharpe and Sherman, 1976), were irradiated by electron beam at 0, 0.25, 0.5, 0.75, or 1.0 kGy to determine its effects on condition and quality after treatment and subsequent storage. Berry firmness was not affected by increased doses following 1 or 3 days of storage at 1C, but it declined with higher doses when stored for 7 days at 1C. In general, berry flavor and texture declined as dosage increased; however, neither flavor nor texture were rated unacceptable by a sensory panel. Weight loss, decay, soluble solids concentration, acidity, pH, skin color, or waxy bloom were not affected by dosage or storage

  2. Examination of the properties of IMRT and VMAT beams and evaluation against pre-treatment quality assurance results

    International Nuclear Information System (INIS)

    Crowe, S B; Kairn, T; Langton, C M; Trapp, J V; Middlebrook, N; Sutherland, B; Hill, B; Kenny, J

    2015-01-01

    This study aimed to provide a detailed evaluation and comparison of a range of modulated beam evaluation metrics, in terms of their correlation with QA testing results and their variation between treatment sites, for a large number of treatments. Ten metrics including the modulation index (MI), fluence map complexity, modulation complexity score (MCS), mean aperture displacement (MAD) and small aperture score (SAS) were evaluated for 546 beams from 122 intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) treatment plans targeting the anus, rectum, endometrium, brain, head and neck and prostate. The calculated sets of metrics were evaluated in terms of their relationships to each other and their correlation with the results of electronic portal imaging based quality assurance (QA) evaluations of the treatment beams. Evaluation of the MI, MAD and SAS suggested that beams used in treatments of the anus, rectum, head and neck were more complex than the prostate and brain treatment beams. Seven of the ten beam complexity metrics were found to be strongly correlated with the results from QA testing of the IMRT beams (p < 0.00008). For example, values of SAS (with multileaf collimator apertures narrower than 10 mm defined as ‘small’) less than 0.2 also identified QA passing IMRT beams with 100% specificity. However, few of the metrics are correlated with the results from QA testing of the VMAT beams, whether they were evaluated as whole 360° arcs or as 60° sub-arcs. Select evaluation of beam complexity metrics (at least MI, MCS and SAS) is therefore recommended, as an intermediate step in the IMRT QA chain. Such evaluation may also be useful as a means of periodically reviewing VMAT planning or optimiser performance. (paper)

  3. Low-Bandwidth Channel Quality Indication for OFDMA Frequency Domain Packet Scheduling

    DEFF Research Database (Denmark)

    Kolding, Troels E.; Frederiksen, Frank; Pokhariyal, Akhilesh

    2007-01-01

     In this paper, we study methods for lowering the bandwidth needed for the UE to transmit channel quality indication (CQI) for time and frequency domain scheduling (FDPS) in OFDMA. We consider smart compression methods, such as threshold based indication, to only include scheduler-relevant inform...... In this paper, we study methods for lowering the bandwidth needed for the UE to transmit channel quality indication (CQI) for time and frequency domain scheduling (FDPS) in OFDMA. We consider smart compression methods, such as threshold based indication, to only include scheduler......-relevant information in the CQI. We find that a 60-70% CQI bandwidth reduction is possible with less than 5-10% impact on scheduling performance. Further, we consider the impact of lowering the CQI reporting rate on both mobility performance and increased measuring accuracy due to longer averaging interval. We find...

  4. The use of oxygen indicators - elements of intelligent packaging for monitoring of food quality

    Directory of Open Access Journals (Sweden)

    Renata Dobrucka

    2014-06-01

    Full Text Available Background: Producers and researchers are looking at not only the methods of protection against ingress of oxygen into the package, but also want to provide consumers with guarantees of quality food they buy. Therefore, large-scale studies are conducted and implementation of intelligent packaging. The operation of these packages is the use of interactive, the most colorful indicators to assess the quality of the packaged product. Methods: This article describes intelligent packaging technologies and presents research for different types of oxygen indicators. Results and conclusion: Indicators for the detection of oxygen allows the consumer to provide some information on the suitability of the product for consumption. Apart from that, they are a simple tool that allows you to reduce the costs associated with loss replacement, repair damaged products or their disposal. Construction of indicator contained in the package is related to the specific product and factor to be controlled.

  5. The Resident Assessment Instrument-Minimum Data Set 2.0 quality indicators: a systematic review

    Directory of Open Access Journals (Sweden)

    Squires Janet E

    2010-06-01

    Full Text Available Abstract Background The Resident Assessment Instrument-Minimum Data Set (RAI-MDS 2.0 is designed to collect the minimum amount of data to guide care planning and monitoring for residents in long-term care settings. These data have been used to compute indicators of care quality. Use of the quality indicators to inform quality improvement initiatives is contingent upon the validity and reliability of the indicators. The purpose of this review was to systematically examine published and grey research reports in order to assess the state of the science regarding the validity and reliability of the RAI-MDS 2.0 Quality Indicators (QIs. Methods We systematically reviewed the evidence for the validity and reliability of the RAI-MDS 2.0 QIs. A comprehensive literature search identified relevant original research published, in English, prior to December 2008. Fourteen articles and one report examining the validity and/or reliability of the RAI-MDS 2.0 QIs were included. Results The studies fell into two broad categories, those that examined individual quality indicators and those that examined multiple indicators. All studies were conducted in the United States and included from one to a total of 209 facilities. The number of residents included in the studies ranged from 109 to 5758. One study conducted under research conditions examined 38 chronic care QIs, of which strong evidence for the validity of 12 of the QIs was found. In response to these findings, the 12 QIs were recommended for public reporting purposes. However, a number of observational studies (n = 13, conducted in "real world" conditions, have tested the validity and/or reliability of individual QIs, with mixed results. Ten QIs have been studied in this manner, including falls, depression, depression without treatment, urinary incontinence, urinary tract infections, weight loss, bedfast, restraint, pressure ulcer, and pain. These studies have revealed the potential for systematic bias in

  6. ASSESSMENT OF LAND QUALITY USING ECOPEDOLOGICAL INDICATORS - JEBEL AREA, TIMIŞ COUNTY, ROMANIA

    Directory of Open Access Journals (Sweden)

    Costina Roxana URUIOC

    2012-01-01

    Full Text Available The studied area is placed in North-East Jebel locality. Based on the physical and chemical characteristics and soil morphology profile, the following types of soil were identified: typical preluvosol, typical and gleyic eutricambosols, luvic solonet, gleysol, gleyic vertisol and gleyic-stagnic vertisol. The assessment of land quality (fertility was determined by bonitation. For the notes of bonitation calculation, the following ecopedological indicatories have been used: annual medium temperature, annual medium precipitations, depth of the underground water, texture in Ap horizon, gleization, pseudogleization, salinization, edafic volume, porosity, soil reaction (pH, humus reserve and content of CaCO3. The way that these indicators influence the notes of bonitation is different from a type of soil to another and the use of land. Thus, for grassland, typical preluvosol, the note of bonitate is 81 and it’s included in class II of quality (favorability, luvic solonet with 63 points in class IV of quality, typical eutricambosols with 58 points and vertisol with 57 points, in class V of quality, gleysol with 32 points and gleyic eutricambosol with 36 points, in class VII of quality. In case of using the land for growing maize, we have the following: typical preluvosol with 90 points which is in class II of quality, typical eutricambosol with 54 points and gleyic vertisol with 60 points, in class V of quality, luvic solonet with 49 points in class VI of quality, gleyic-stagnic vertisol with 35 points, in class VII of quality, gleysol with 24 points and gleyic eutricambosol with 29 points, in class VIII of quality. The notes of bonitation calculation, including them in the favorability classes, showed up that lands from Jebel area are good and very good quality, exception those that develop on gleysol and gleyic eutricambosols soils.

  7. Long-term effects of soil management practices on selected indicators of chemical soil quality

    Directory of Open Access Journals (Sweden)

    Alicja Pecio

    2016-06-01

    Full Text Available The study was conducted in scope of Catch-C project “Compatibility of agricultural management practices and types of farming in the EU to enhance climate change mitigation and soil health” (7FP, realized in 2012–2014 by the consortium of partners from 10 European countries (http://www.catch-c.eu. This work reports the effects of soil management practices – under different soil and climatic conditions – on the selected soil chemical quality indicators, based on the analysis of data extracted from literature on long term experiments (LTEs in Europe, as well as from LTEs held by the Catch-C consortium partners. The dataset related to soil chemical quality indicators consisted of 1044 records and referred to 59 long-term trials. The following indicators of chemical soil quality were analyzed: pH, N total content, N total stock, C:N ratio, N mineral content, P and K availability. They are the most frequently used indicators in the European literature on long-term experiments collected in the Catch-C project database. Soil organic carbon, however, the most important indicator was not presented here, due to it was covered by a separate study on indicators for climate change mitigation. The indicators were analyzed using their response ratio (RR to a management practice. For a given treatment (management practice, this ratio was calculated as the quotient between the indicator value obtained in the treatment, and the indicator value in the reference treatment. The examples were: rotation (with cereals, with legume crops, with tuber or root crops, with grassland vs. adequate monoculture, catch/cover crops vs. no catch/cover crops, no-tillage and no-inversion tillage vs. conventional tillage, mineral fertilization vs. no fertilization, organic fertilization (compost, farmyard manure, slurry vs. mineral fertilization at the same available nitrogen input, crop residue incorporation vs. removal. All tested practices influenced soil chemical quality

  8. Performance Assesment of Bauchi Polytechnics and Technical Colleges Using Quality Assurance Indicators in Nigeria Qualification Framework

    Directory of Open Access Journals (Sweden)

    Idris Adamu

    2016-07-01

    Full Text Available Technical and Vocational Education emphases skill acquisition, Quality Assurance in vocational education is concept that is concerned with high performance involved activities with vocational education such as teaching, learning, infrastructures, student’s behavior and entire academic process. Good quality education is very necessary in the total development of staff and students which ensures proper development, job prospects and the realization of academic goals and objects. Enhanced and sustained to ensure accountability and improve performance. Higher educational institutions in Nigeria continue to experience carelessly attitude about the use of Quality Assurance to understand the risk they are exposed to poor standard. To address these issues, the study embarked upon to determine the level of performance and difference usability of Quality Assurance in Polytechnics and Technical Colleges in Bauchi state. Quantitative method technique was employed using survey questionnaires, 60 staff both senior and junior within these institutions were selected and a questionnaire distributed for their responses. The data were analysed using SPSS software. The result reveals that Federal Polytechnic Bauchi and State Polytechnic Bauchi has high level of Performance about Quality Assurance indicators while College of Education Azare has medium level of Performance. College of education Azare has highest mean rank of 29.87 and percentage of 31.8% obtained from the output result indicated that it has high usability to Quality Assurance, followed by Federal Polytechnic Bauchi with medium usability then State Polytechnic Bauchi has low usability to Quality Assurance. The study concluded by Quality Assurance Unit be made aware to each institution staff to enable recognize the benefits of it. Federal government should give more funding and employ staff to cater the need of Quality Assurance Unit in every institution so that it will help the students to develop

  9. [Quality management in a clinical research facility: Evaluation of changes in quality in-house figures and the appraisal of in-house quality indicators].

    Science.gov (United States)

    Aden, Bile; Allekotte, Silke; Mösges, Ralph

    2016-12-01

    For long-term maintenance and improvement of quality within a clinical research institute, the implementation and certification of a quality management system is suitable. Due to the implemented quality management system according to the still valid DIN EN ISO 9001:2008 desired quality objectives are achieved effectively. The evaluation of quality scores and the appraisal of in-house quality indicators make an important contribution in this regard. In order to achieve this and draw quality assurance conclusions, quality indicators as sensible and sensitive as possible are developed. For this, own key objectives, the retrospective evaluation of quality scores, a prospective follow-up and also discussions establish the basis. In the in-house clinical research institute the measures introduced by the quality management led to higher efficiency in work processes, improved staff skills, higher customer satisfaction and overall to more successful outcomes in relation to the self-defined key objectives. Copyright © 2016. Published by Elsevier GmbH.

  10. [The ATMO index: an air quality indicator for developed areas in France].

    Science.gov (United States)

    2003-05-01

    The LAURE (5) of 30 december, 1996, sets the preventive, monitoring, reduction or suppression of atmospheric pollution objectives and the goals for preserving air quality. Heading 1--Article 4 of the law states in particular that the right to information on air quality and its impact on the environment is recognised as the right of every person on French territory. The decree of 10 january, 2000, about the air-quality index is derived from this determination to information for all, stated as an important element in the policy for air-quality management. This decree provides definitions of the ATMO index with "standards 2000" and the recommendations required for its calculation. Previously (1992 and before), certain local agencies had developed their own index. Naturally these indices showed sizeable differences. The effort provided by the Ministry of the Environment, ADEME and the monitoring agencies, enabled the definition of a single index for the whole of the large urban areas (> 100,000 inhabitants). The index gives a common language to the non-specialist public, which can now understand the overall air quality in different urban areas. As all aggregate indicators of the same kind, the ATMO index is designed as a tool that makes it possible to translate in a quantitative and simple way the synthesis of numerous measurement data recorded daily by official air-quality monitoring agencies (AASQA).

  11. Quality indicators for acute myocardial infarction: A position paper of the Acute Cardiovascular Care Association.

    Science.gov (United States)

    Schiele, Francois; Gale, Chris P; Bonnefoy, Eric; Capuano, Frederic; Claeys, Marc J; Danchin, Nicolas; Fox, Keith Aa; Huber, Kurt; Iakobishvili, Zaza; Lettino, Maddalena; Quinn, Tom; Rubini Gimenez, Maria; Bøtker, Hans E; Swahn, Eva; Timmis, Adam; Tubaro, Marco; Vrints, Christiaan; Walker, David; Zahger, Doron; Zeymer, Uwe; Bueno, Hector

    2017-02-01

    Evaluation of quality of care is an integral part of modern healthcare, and has become an indispensable tool for health authorities, the public, the press and patients. However, measuring quality of care is difficult, because it is a multifactorial and multidimensional concept that cannot be estimated solely on the basis of patients' clinical outcomes. Thus, measuring the process of care through quality indicators (QIs) has become a widely used practice in this context. Other professional societies have published QIs for the evaluation of quality of care in the context of acute myocardial infarction (AMI), but no such indicators exist in Europe. In this context, the European Society of Cardiology (ESC) Acute Cardiovascular Care Association (ACCA) has reflected on the measurement of quality of care in the context of AMI (ST segment elevation myocardial infarction (STEMI) and non-ST segment elevation myocardial infarction (NSTEMI)) and created a set of QIs, with a view to developing programmes to improve quality of care for the management of AMI across Europe. We present here the list of QIs defined by the ACCA, with explanations of the methodology used, scientific justification and reasons for the choice for each measure.

  12. DNA Source Selection for Downstream Applications Based on DNA Quality Indicators Analysis

    Science.gov (United States)

    Lucena-Aguilar, Gema; Sánchez-López, Ana María; Barberán-Aceituno, Cristina; Carrillo-Ávila, José Antonio; López-Guerrero, José Antonio

    2016-01-01

    High-quality human DNA samples and associated information of individuals are necessary for biomedical research. Biobanks act as a support infrastructure for the scientific community by providing a large number of high-quality biological samples for specific downstream applications. For this purpose, biobank methods for sample preparation must ensure the usefulness and long-term functionality of the products obtained. Quality indicators are the tool to measure these parameters, the purity and integrity determination being those specifically used for DNA. This study analyzes the quality indicators in DNA samples derived from 118 frozen human tissues in optimal cutting temperature (OCT) reactive, 68 formalin-fixed paraffin-embedded (FFPE) tissues, 119 frozen blood samples, and 26 saliva samples. The results obtained for DNA quality are discussed in association with the usefulness for downstream applications and availability of the DNA source in the target study. In brief, if any material is valid, blood is the most approachable option of prospective collection of samples providing high-quality DNA. However, if diseased tissue is a requisite or samples are available, the recommended source of DNA would be frozen tissue. These conclusions will determine the best source of DNA, according to the planned downstream application. Furthermore our results support the conclusion that a complete procedure of DNA quantification and qualification is necessary to guarantee the appropriate management of the samples, avoiding low confidence results, high costs, and a waste of samples. PMID:27158753

  13. DNA Source Selection for Downstream Applications Based on DNA Quality Indicators Analysis.

    Science.gov (United States)

    Lucena-Aguilar, Gema; Sánchez-López, Ana María; Barberán-Aceituno, Cristina; Carrillo-Ávila, José Antonio; López-Guerrero, José Antonio; Aguilar-Quesada, Rocío

    2016-08-01

    High-quality human DNA samples and associated information of individuals are necessary for biomedical research. Biobanks act as a support infrastructure for the scientific community by providing a large number of high-quality biological samples for specific downstream applications. For this purpose, biobank methods for sample preparation must ensure the usefulness and long-term functionality of the products obtained. Quality indicators are the tool to measure these parameters, the purity and integrity determination being those specifically used for DNA. This study analyzes the quality indicators in DNA samples derived from 118 frozen human tissues in optimal cutting temperature (OCT) reactive, 68 formalin-fixed paraffin-embedded (FFPE) tissues, 119 frozen blood samples, and 26 saliva samples. The results obtained for DNA quality are discussed in association with the usefulness for downstream applications and availability of the DNA source in the target study. In brief, if any material is valid, blood is the most approachable option of prospective collection of samples providing high-quality DNA. However, if diseased tissue is a requisite or samples are available, the recommended source of DNA would be frozen tissue. These conclusions will determine the best source of DNA, according to the planned downstream application. Furthermore our results support the conclusion that a complete procedure of DNA quantification and qualification is necessary to guarantee the appropriate management of the samples, avoiding low confidence results, high costs, and a waste of samples.

  14. Image quality and dose for a multisource cone-beam CT extremity scanner.

    Science.gov (United States)

    Gang, Grace J; Zbijewski, Wojciech; Mahesh, Mahadevappa; Thawait, Gaurav; Packard, Nathan; Yorkston, John; Demehri, Shadpour; Siewerdsen, Jeffrey H

    2018-01-01

    This work investigates the dose characteristics and image quality of a multisource cone-beam CT scanner dedicated for extremity imaging. The scanner has an x-ray source with three separate anode-cathode units evenly distributed along the longitudinal direction. A nominal scan protocol fires the three sources sequentially, and a total of 600 projections (200 for each source) are acquired over a source-detector orbit of 210 o . Dose was measured using a Farmer chamber in three CTDI phantoms stacked end-to-end. Measurements were performed at the central and four peripheral locations of a CTDI phantom on the axial plane and repeated along the longitudinal direction. The extent of 3D sampling of the three-source configuration was assessed in the Fourier domain through noise power spectrum measurements from air scans and compared with that from a single-source scan. A modified Defrise phantom and anthropomorphic knee and hand phantoms were used for visual assessment of cone-beam artifacts in the reconstructed images. The dose distribution for the three-source configuration exhibits radial asymmetry on the axial plane consistent with a short-scan geometry. Along the longitudinal direction, the highest dose was measured at the central axial plane where the field of view (FOV) from all three sources overlaps and falls off more slowly toward the end compared to a single-source configuration. The extent of 3D sampling is improved throughout the FOV as each source compensates for missing frequencies from the adjacent source. As a result, the reduction in streak and shading artifacts is apparent in the reconstructed images of all three phantoms. The improvement in image quality from the three-source configuration is most pronounced in joint spaces farther from the central axial plane. Initial assessment of the multisource scanner demonstrated the advantages over single-source designs in a compact scanner with large longitudinal FOV. The reduction in cone-beam artifact is

  15. Quality indicators for the design and implementation of simulation experiences: a Delphi study.

    Science.gov (United States)

    Arthur, Carol; Levett-Jones, Tracy; Kable, Ashley

    2013-11-01

    Simulation is widely used in nursing education. Previous studies have examined the impact of simulation on the acquisition of psychomotor skills, knowledge, critical thinking and non-technical skills such as teamwork. Challenges associated with the integration of simulation into nursing curricula have also been examined, however only limited research addresses the most effective simulation design and teaching strategies for quality educational outcomes. This paper reports a Delphi study that synthesises expert opinion on the pedagogical principles and teaching strategies that are indicative of quality in simulation based learning activities. The resultant set of Quality Indicator Statements is presented and opportunities for application and further research are discussed. Copyright © 2012 Elsevier Ltd. All rights reserved.

  16. Quality indicators for physiotherapy care in hip and knee osteoarthritis: development and clinimetric properties

    NARCIS (Netherlands)

    Peter, W.F.; Wees, P.J. van der; Hendriks, E.J.; Bie, R.A. de; Verhoef, J.; Jong, Z. de; Bodegom-Vos, L. van; Hilberdink, W.K.H.A.; Vlieland, T.P.

    2013-01-01

    OBJECTIVE: The aim of the present study was to develop process quality indicators for physiotherapy care based on key recommendations of the Dutch physiotherapy guideline on hip and knee osteoarthritis (OA). METHODS: Guideline recommendations were rated for their relevance by an expert panel,

  17. Air quality indicators from the Environmental Performance Index: potential use and limitations in South Africa

    CSIR Research Space (South Africa)

    Garland, Rebecca M

    2017-05-01

    Full Text Available values, as well as number of exceedances of South African National Ambient Standards. However, these do not directly communicate the potential impact on human health and the ecosystem. To this end, the use of air quality indicators is seen as a potential...

  18. Indicators and standards of quality for the Schoodic Peninsula section of Acadia National Park, Maine

    Science.gov (United States)

    James Bacon; Robert Manning; Steven Lawson; William Valliere; Daniel Laven

    2003-01-01

    A multi-year research initiative was undertaken to inform park planning and management efforts at the Schoodic Peninsula Section of Acadia National Park, Maine. This research focused on developing information that will enable formulation of indicators and standards of quality. The first phase of research in the summer of 2000 obtained descriptive information on visitor...

  19. Key Performance Indicators of Public Universities Based on Quality Assessment Criteria in Thailand

    Science.gov (United States)

    Sukboonyasatit, Kritsana; Thanapaisarn, Chaiwit; Manmar, Lampang

    2011-01-01

    The research objective was to develop public universities' key performance indicators. Qualitative research and interviews were employed with each public university's senior executive and quality assessors. The sample group was selected by the office of the public sector development commission and Thailand's public universities can be separated…

  20. Environmental Learning Workshop: Lichen as Biological Indicator of Air Quality and Impact on Secondary Students' Performance

    Science.gov (United States)

    Samsudin, Mohd Wahid; Daik, Rusli; Abas, Azlan; Meerah, T. Subahan Mohd; Halim, Lilia

    2013-01-01

    In this study, the learning of science outside the classroom is believe to be an added value to science learning as well as it offers students to interact with the environment. This study presents data obtained from two days' workshop on Lichen as Biological Indicator for Air Quality. The aim of the workshop is for the students to gain an…

  1. Audit of cases with uterine rupture: A process indicator of quality of ...

    African Journals Online (AJOL)

    Audit of uterine rupture (UR) used as a process indicator, can identify factors considered avoidable to improve future quality of obstetric care. Records of UR cases at a referral maternity in Luanda were studied retrospectively (n=43) and prospectively (n=67) including basic obstetric information, maternal and foetal outcome, ...

  2. [Ressenya del llibre Landscape indicators: Assessing and monitoring landscape quality, de Claudia Cassatella, Attilia Peano (eds.)

    OpenAIRE

    Llausàs i Pascual, Albert

    2012-01-01

    Ressenya de 'Landscape indicators: assessing and monitoring landscape quality', un llibre que fa un repàs de l'estat de la qüestió dels indicadors del paisatge i formula propostes a partir d’experiències d’aplicació a la regió italiana del Piemonte

  3. Productivity as an Indication of Quality in Higher Education: The Views of Employed Graduates in Greece

    Science.gov (United States)

    Eliophotou Menon, Maria

    2016-01-01

    The paper investigates the views of Greek university graduates on the link between higher education and productivity in order to determine the extent to which productivity can be considered to be an indication of quality in higher education. It also investigates the perceived effect of the type and content of higher education on productivity;…

  4. Quality of life before and after lung transplantation in patients with emphysema versus other indications

    NARCIS (Netherlands)

    TenVergert, EM; Vermeulen, KM; van Enckevort, PJ

    2001-01-01

    Whether lung transplantation improves Health-related Quality of Life in patients with emphysema and other end-stage lung diseases before and after lung transplantation was examined. Between 1992 and 1999, 23 patients with emphysema and 19 patients with other indications completed self-administered

  5. Using the "Indicators of Engaged Learning Online" Framework to Evaluate Online Course Quality

    Science.gov (United States)

    Bigatel, Paula M.; Edel-Malizia, Stephanie

    2018-01-01

    This article is a case study of the use of the "Indicators of Engaged Learning Online" (IELO) framework (See Appendix 1) as a guide to evaluate the quality of online courses. The framework lends itself well to measures of engagement, particularly, in terms of online course design because of its comprehensiveness. Six online courses were…

  6. Water quality as bio-cultural screening indicator for the integrity of ...

    African Journals Online (AJOL)

    2016-10-04

    Oct 4, 2016 ... Water quality as bio-cultural screening indicator for the integrity of informal heritage sites. S Cawood1 and AT Vos2*. 1Centre for Africa Studies, University of the Free State, PO Box 339, Bloemfontein, 9300, South Africa. 2Centre for Environmental Management, University of the Free State, PO Box 339, ...

  7. Indicators of quality use of medicines in South-East Asian countries : a systematic review

    NARCIS (Netherlands)

    Nguyen, H. T.; Wirtz, V. J.; Haaijer-Ruskamp, F. M.; Taxis, K.

    2012-01-01

    Objectives To identify indicators of quality use of medicines used in South-East Asian region. Methods A systematic review was conducted searching MEDLINE, Embase and The International Network for Rational Use of Drugs (INRUD) and The World Health Organization (WHO) website. Original studies or

  8. Establishing Content Validity of the Quality Indicators for Classrooms Serving Students with Autism Spectrum Disorders Instrument

    Science.gov (United States)

    Pearl, Cynthia E.; Vasquez, Eleazar, III.; Marino, Matthew T.; Wienke, Wilfred; Donehower, Claire; Gourwitz, Jillian; Rosenberg, Michael S.; Duerr, Sunny R.

    2018-01-01

    The purpose of this study was to provide content validation for quality indicators included in an observation instrument developed to evaluate classrooms serving students with autism spectrum disorders (ASD). A panel of 103 subject-matter experts consisting of a mixture of field personnel (n = 64; 59 classroom teachers, five school administrators)…

  9. Guideline-based development of quality indicators for prevention and management of postpartum hemorrhage

    NARCIS (Netherlands)

    Woiski, M.D.; Scheepers, H.C.; Liefers, J.; Lance, M.; Middeldorp, J.M.; Lotgering, F.K.; Grol, R.P.; Hermens, R.P.M.G.

    2015-01-01

    INTRODUCTION: To systematically develop a set of guideline-based quality indicators for postpartum hemorrhage (PPH) as a tool to measure guideline adherence in actual PPH care. MATERIAL AND METHODS: A Rand-modified Delphi procedure was used to systematically achieve consensus among a panel of 22

  10. Postpartum haemorrhage in midwifery care in the Netherlands: validation of quality indicators for midwifery guidelines

    NARCIS (Netherlands)

    Smit, M.; Chan, K.L.L.; Middeldorp, J.M.; van Roosmalen, J.

    2014-01-01

    Background: Postpartum haemorrhage (PPH) is still one of the major causes of severe maternal morbidity and mortality worldwide. Currently, no guideline for PPH occurring in primary midwifery care in the Netherlands is available. A set of 25 quality indicators for prevention and management of PPH in

  11. Development of quality indicators for physiotherapy for patients with PAOD in the Netherlands: a Delphi study

    NARCIS (Netherlands)

    Gijsbers, H. J. H.; Lauret, G. J.; van Hofwegen, A.; van Dockum, T. A.; Teijink, J. A. W.; Hendriks, H. J. M.

    2016-01-01

    The aim of the study was to develop quality indicators (QIs) for physiotherapy management of patients with intermittent claudication (IC) in the Netherlands. As part of an international six-step method to develop QIs, an online survey Delphi-procedure was completed. After two Delphi-rounds a

  12. Comparison of indicators assessing the quality of drug prescribing for asthma

    NARCIS (Netherlands)

    Veninga, C.C.M.; Denig, P.; Pont, L.G.; Haaijer-Ruskamp, F.M.

    Objective. To compare different indicators for assessing the quality of drug prescribing and establish their agreement in identifying doctors who may not adhere to treatment guidelines. Data Sources/Study Setting. Data from 181 general practitioners (GPs) from The Netherlands. The case of asthma is

  13. Design of a Highly Stable, High-Conversion-Efficiency, Optical Parametric Chirped-Pulse Amplification System with Good Beam Quality

    International Nuclear Information System (INIS)

    Guardalben, M.J.; Keegan, J.; Waxer, L.J.; Bagnoud, V.; Begishev, I.A.; Puth, J.; Zuegel, J.D.

    2003-01-01

    OAK B204 An optical parametric chirped-pulse amplifier (OPCPA) design that provides 40% pump-to-signal conversion efficiency and over-500-mJ signal energy at 1054 nm for front-end injection into a Nd:glass amplifier chain is presented. This OPCPA system is currently being built as the prototype front end for the OMEGA EP (extended performance) laser system at the University of Rochester's Laboratory for Laser Energetics. Using a three-dimensional spatial and temporal numerical model, several design considerations necessary to achieve high conversion efficiency, good output stability, and good beam quality are discussed. The dependence of OPCPA output on the pump beam's spatiotemporal shape and the relative size of seed and pump beams is described. This includes the effects of pump intensity modulation and pump-signal walk-off. The trade-off among efficiency, stability, and low output beam intensity modulation is discussed

  14. IEC 61267: Feasibility of type 1100 aluminium and a copper/aluminium combination for RQA beam qualities.

    Science.gov (United States)

    Leong, David L; Rainford, Louise; Zhao, Wei; Brennan, Patrick C

    2016-01-01

    In the course of performance acceptance testing, benchmarking or quality control of X-ray imaging systems, it is sometimes necessary to harden the X-ray beam spectrum. IEC 61267 specifies materials and methods to accomplish beam hardening and, unfortunately, requires the use of 99.9% pure aluminium (Alloy 1190) for the RQA beam quality, which is expensive and difficult to obtain. Less expensive and more readily available filters, such as Alloy 1100 (99.0% pure) aluminium and copper/aluminium combinations, have been used clinically to produce RQA series without rigorous scientific investigation to support their use. In this paper, simulation and experimental methods are developed to determine the differences in beam quality using Alloy 1190 and Alloy 1100. Additional simulation investigated copper/aluminium combinations to produce RQA5 and outputs from this simulation are verified with laboratory tests using different filter samples. The results of the study demonstrate that although Alloy 1100 produces a harder beam spectrum compared to Alloy 1190, it is a reasonable substitute. A combination filter of 0.5 mm copper and 2 mm aluminium produced a spectrum closer to that of Alloy 1190 than Alloy 1100 with the added benefits of lower exposures and lower batch variability. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  15. Do treatment quality indicators predict cardiovascular outcomes in patients with diabetes?

    Directory of Open Access Journals (Sweden)

    Grigory Sidorenkov

    Full Text Available BACKGROUND: Landmark clinical trials have led to optimal treatment recommendations for patients with diabetes. Whether optimal treatment is actually delivered in practice is even more important than the efficacy of the drugs tested in trials. To this end, treatment quality indicators have been developed and tested against intermediate outcomes. No studies have tested whether these treatment quality indicators also predict hard patient outcomes. METHODS: A cohort study was conducted using data collected from >10.000 diabetes patients in the Groningen Initiative to Analyze Type 2 Treatment (GIANTT database and Dutch Hospital Data register. Included quality indicators measured glucose-, lipid-, blood pressure- and albuminuria-lowering treatment status and treatment intensification. Hard patient outcome was the composite of cardiovascular events and all-cause death. Associations were tested using Cox regression adjusting for confounding, reporting hazard ratios (HR with 95% confidence intervals. RESULTS: Lipid and albuminuria treatment status, but not blood pressure lowering treatment status, were associated with the composite outcome (HR = 0.77, 0.67-0.88; HR = 0.75, 0.59-0.94. Glucose lowering treatment status was associated with the composite outcome only in patients with an elevated HbA1c level (HR = 0.72, 0.56-0.93. Treatment intensification with glucose-lowering but not with lipid-, blood pressure- and albuminuria-lowering drugs was associated with the outcome (HR = 0.73, 0.60-0.89. CONCLUSION: Treatment quality indicators measuring lipid- and albuminuria-lowering treatment status are valid quality measures, since they predict a lower risk of cardiovascular events and mortality in patients with diabetes. The quality indicators for glucose-lowering treatment should only be used for restricted populations with elevated HbA1c levels. Intriguingly, the tested indicators for blood pressure-lowering treatment did not predict patient

  16. Compassionate collaborative care: an integrative review of quality indicators in end-of-life care.

    Science.gov (United States)

    Pfaff, Kathryn; Markaki, Adelais

    2017-12-01

    Compassion and collaborative practice are individually associated with high quality healthcare. When combined in a compassionate collaborative care (CCC) practice framework, they are reported to improve health, strengthen care provision, and control health costs. Little is known about how to integrate and measure CCC, yet it is fundamentally applied in palliative and end-of-life care settings. This study aimed to identify quality indicators of CCC by systematically reviewing and synthesizing the current state of the palliative and end-of-life care literature. An integrative review of the palliative and end-of-life care literature was conducted using Whittemore and Knafl's method. Donabedian's healthcare quality framework was applied in the data analysis phase to organize and display the data. The analysis involved an iterative process that applied a constant comparative method. The final literature sample included 25 articles. Patient and family-centered care emerged as a primary structure for CCC, with overarching values including empathy, sharing, respect, and partnership. The analysis revealed communication, shared decision-making, and goal setting as overarching processes for achieving CCC at end-of-life. Patient and family satisfaction, enhanced teamwork, decreased staff burnout, and organizational satisfaction are exemplars of outcomes that suggest high quality CCC. Specific quality indicators at the individual, team and organizational levels are reported with supporting exemplar data. CCC is inextricably linked to the inherent values, needs and expectations of patients, families and healthcare providers. Compassion and collaboration must be enacted and harmonized to fully operationalize and sustain patient and family-centered care in palliative and end-of-life practice settings. Towards that direction, the quality indicators that emerged from this integrative review provide a two-fold application in palliative and end-of-life care. First, to evaluate the

  17. Evaluation of quality indicators and disease damage in childhood-onset systemic lupus erythematosus patients.

    Science.gov (United States)

    Harris, Julia G; Maletta, Kristyn I; Kuhn, Evelyn M; Olson, Judyann C

    2017-02-01

    The aim of this study was to describe compliance with select quality indicators and assess organ-specific dysfunction in a childhood-onset systemic lupus erythematosus population by using a validated damage index and to evaluate associations between compliance with quality indicators and disease damage. A retrospective chart review was performed on patients diagnosed with systemic lupus erythematosus prior to age 18 followed at a single center in the USA from 1999 to 2012 (n = 75). Data regarding quality indicators and outcome variables, including the Systemic Lupus International Collaborating Clinics/American College of Rheumatology Damage Index, were collected. The median disease duration was 3.8 years. The proportion of patients or patient-years in which care complied with the proposed quality measures was 94.4% for hydroxychloroquine use, 84.3% for vitamin D recommendation,75.8% for influenza vaccination (patient-years), 67.2% for meningococcal vaccination, 49.0% for ophthalmologic examination (patient-years), 31.7% for pneumococcal vaccination, and 28.6% for bone mineral density evaluation. Disease damage was present in 41.3% of patients at last follow-up, with an average damage index score of 0.81. Disease damage at last follow-up was associated with minority race/ethnicity (p = 0.008), bone mineral density evaluation (p = 0.035), and vitamin D recommendation (p = 0.018). Adherence to quality indicators in a childhood-onset systemic lupus erythematosus population is varied, and disease damage is prevalent. This study highlights the importance of quality improvement initiatives aimed at optimizing care delivery to reduce disease damage in pediatric lupus patients.

  18. Experiences from the evaluation of two global quality indicators in a radiology service

    International Nuclear Information System (INIS)

    Hernandez Lopez, L. Y.; Valdes Arce, Y.; Fleitas Estevez, I.

    2013-01-01

    The main objective in radiology is to obtain images of good quality for certain diagnosis, without unnecessarily irradiating the patient. This paper shows the results of the reject films and clinical image quality evaluations in the radiology service of the Hospital 'Abel Santamaria Cuadrado', Pinar del Rio, Cuba. Data were collected during March and September of 2012. Reject films analysis was done for conventional and mammography studies. Clinical image quality evaluated following the European Guidelines on Quality Criteria. The results show that reject films rate decreased from 6% on March to 1.3% on September, after applying corrective actions; while chests studies have the highest reject rate. The mean causes for rejections were maladjustments in the collimation system, equipment faults, sub exposure and overexposure. For mammography studies the initial reject rate was 29.3% and decreased to 5.9% on September. Mean causes for rejection were related to faults in the automatic processor and the mammography x-ray unit. Image quality also improved: only 48.3% of chest images and 10% of mammography images were considered to be acceptable for diagnosis at the first moment; while these percentages increased to 68.3% and 70% for chest and mammography studies, respectively in the September's evaluation. The study demonstrated that the frequently evaluation of the quality's indicators allows to identify the main causes of the image's detriment to propose corrective actions. Still in situations of insufficient resources it is possible to improve quality with simple interventions on the main faults detected. (Author)

  19. Quality in cytopathology: an analysis of the internal quality monitoring indicators of the Instituto Nacional de Câncer

    Directory of Open Access Journals (Sweden)

    Mario Lucio C. Araujo Jr

    2015-04-01

    Full Text Available Introduction: Quality control programs are required to ensure the effectiveness of Pap smear, which still remain a key strategy for control of cervical cancer worldwide. Objective: This study was based on the retrospective and quantitative analysis of the post-analytical phase indicators from the internal quality monitoring (IQM program for cytopathology laboratories, such as: positivity rate, atypical squamous cell (ASC/satisfactory exams ratio, ASC/abnormal test results ratio, ASC/squamous intraepithelial lesions (SIL ratio, percentage of tests compatible with high-grade squamous intraepithelial lesion (HSIL, and total of false negative. Materials and methods: The information was extracted from the computerized system of the Section for Integrated Technology in Cytopathology (Seção Integrada de Tecnologia em Citopatologia [SITEC], a reference institution for cancer cytopathology, from July 2013 to June 2014. From a total of 156,888 Pap smears, 157,454 were considered satisfactory for indicator analysis and 566 were excluded because they were considered unsatisfactory and/or rejected for analysis. The data was organized in tables using Microsoft Excel 2010 software, and categorized as indicators. Results: The averages for the indicators were: 7.2% for positivity rate, 56.9 for ASC/abnormal test ratio, 4.1 for ASC/satisfactory tests ratio, 1.4 for ASC/SIL ratio, 0.6% percentage for tests compatible with HSIL, and 2.1% for false-negative rate. Conclusion: The results show that an Internal Quality Monitoring Program is essencial to ensure quality for cytopathology laboratories, and a randomized review of at least 10% of the negative exams, as recommended by the Brazilian Ministry of Health/Instituto Nacional de Câncer (INCA, since is an effective method, especially for large laboratories.

  20. Environmental quality indicators and financial development in Malaysia: unity in diversity.

    Science.gov (United States)

    Alam, Arif; Azam, Muhammad; Abdullah, Alias Bin; Malik, Ihtisham Abdul; Khan, Anwar; Hamzah, Tengku Adeline Adura Tengku; Faridullah; Khan, Muhammad Mushtaq; Zahoor, Hina; Zaman, Khalid

    2015-06-01

    Environmental quality indicators are crucial for responsive and cost-effective policies. The objective of the study is to examine the relationship between environmental quality indicators and financial development in Malaysia. For this purpose, the number of environmental quality indicators has been used, i.e., air pollution measured by carbon dioxide emissions, population density per square kilometer of land area, agricultural production measured by cereal production and livestock production, and energy resources considered by energy use and fossil fuel energy consumption, which placed an impact on the financial development of the country. The study used four main financial indicators, i.e., broad money supply (M2), domestic credit provided by the financial sector (DCFS), domestic credit to the private sector (DCPC), and inflation (CPI), which each financial indicator separately estimated with the environmental quality indicators, over a period of 1975-2013. The study used the generalized method of moments (GMM) technique to minimize the simultaneity from the model. The results show that carbon dioxide emissions exert the positive correlation with the M2, DCFC, and DCPC, while there is a negative correlation with the CPI. However, these results have been evaporated from the GMM estimates, where carbon emissions have no significant relationship with any of the four financial indicators in Malaysia. The GMM results show that population density has a negative relationship with the all four financial indicators; however, in case of M2, this relationship is insignificant to explain their result. Cereal production has a positive relationship with the DCPC, while there is a negative relationship with the CPI. Livestock production exerts the positive relationship with the all four financial indicators; however, this relationship with the CPI has a more elastic relationship, while the remaining relationship is less elastic with the three financial indicators in a country

  1. Assessing soil quality indicator under different land use and soil erosion using multivariate statistical techniques.

    Science.gov (United States)

    Nosrati, Kazem

    2013-04-01

    Soil degradation associated with soil erosion and land use is a critical problem in Iran and there is little or insufficient scientific information in assessing soil quality indicator. In this study, factor analysis (FA) and discriminant analysis (DA) were used to identify the most sensitive indicators of soil quality for evaluating land use and soil erosion within the Hiv catchment in Iran and subsequently compare soil quality assessment using expert opinion based on soil surface factors (SSF) form of Bureau of Land Management (BLM) method. Therefore, 19 soil physical, chemical, and biochemical properties were measured from 56 different sampling sites covering three land use/soil erosion categories (rangeland/surface erosion, orchard/surface erosion, and rangeland/stream bank erosion). FA identified four factors that explained for 82 % of the variation in soil properties. Three factors showed significant differences among the three land use/soil erosion categories. The results indicated that based upon backward-mode DA, dehydrogenase, silt, and manganese allowed more than 80 % of the samples to be correctly assigned to their land use and erosional status. Canonical scores of discriminant functions were significantly correlated to the six soil surface indices derived of BLM method. Stepwise linear regression revealed that soil surface indices: soil movement, surface litter, pedestalling, and sum of SSF were also positively related to the dehydrogenase and silt. This suggests that dehydrogenase and silt are most sensitive to land use and soil erosion.

  2. Using diatom indices for water quality assessment in a subtropical river, China.

    Science.gov (United States)

    Tan, Xiang; Sheldon, Fran; Bunn, Stuart E; Zhang, Quanfa

    2013-06-01

    Diatoms have been regularly used as bioindicators to assess water quality of surface waters. However, diatom-based indices developed for a specific geographic region may not be appropriate elsewhere. We sampled benthic diatom assemblages in the upper Han River, a subtropical river in China, to evaluate applicability of 14 diatom-based indices used worldwide for water quality assessment. A total of 194 taxa from 31 genera were identified in the dry season and 139 taxa from 23 genera in the wet season. During the dry season, significant relationships were found for all but one of the diatom-based indices (Index Diatom Artois-Picardie) with one or more physical and chemical variables including nutrients and ion concentrations in river waters. The Biological Diatom Index (IBD) and diatom-based eutrophication/pollution index (EPI-D) were strongly related to trophic status and ionic content, while Watanabe's Index was related to organic pollution and conductivity. Yet, the diatom indices showed weak relationships with physical and chemical variables during the wet season. It suggests that diatom-based indices developed in Europe can be applied with confidence as bioindicators of water quality in subtropical rivers of China, at least during base-flow conditions.

  3. Using Gambusia affinis growth and condition to assess estuarine habitat quality: A comparison of indices

    Science.gov (United States)

    Piazza, Bryan P.; La Peyre, M.K.

    2010-01-01

    Numerous indices have been used to estimate fish growth and condition however, differences in sensitivity and reliability of the methods have hampered efforts to identify appropriate indicators for routine evaluation of habitat quality in the field. We compared common morphometric (length, weight, somatic growth, length-weight condition) and biochemical (RNA:DNA ratio, relative DNA content, energy density) growth indices on the same wild-caught mosquitofish Gambusia affinis to examine their usefulness as indicators of habitat quality. A laboratory experiment was used to quantify growth rates of wild-caught G. affinis under different feeding treatments. Field studies consisted of both a short-term enclosure experiment (10 d) and weekly (7 wk) fish collections to compare growth indices in managed inflow and reference marshes during a winter/spring freshwater pulse event in upper Breton Sound, Louisiana, USA. Marshes flooded by restored freshwater pulses were capable of producing optimum growth (0.001 g DW d-1 DW = dry weight) and energetically valuable habitat (>6000 cal g-1 DW) for trophic transport. Because of differences in timing of response, morphometric and biochemical indices were generally not directly correlated, but there was clear agreement in direction and magnitude of response. The most striking difference in timing was that biochemical indices (RNA:DNA) responded more slowly to treatments than did morphometric growth indices. While gross patterns are comparable between indicators, differences in sensitivity and response time between indicators suggest that choice of indicator needs to be accounted for in interpretation and analysis of effects. ?? Inter-Research 2010, www.int-res.com.

  4. Quality indicators and specifications for key processes in clinical laboratories: a preliminary experience.

    Science.gov (United States)

    Kirchner, Maria Jesus Alsina; Funes, Virtudes Alvarez; Adzet, Carme Biosca; Clar, Maria Vicenta Doménech; Escuer, Mercè Ibarz; Girona, Joana Minchinela; Barellas, Rosa Maria Pastor; Alsina, Carmen Perich; Aguilá, Carmen Ricós; Isern, Gloria Trujillo; Navarro, Conrad Vilanova

    2007-01-01

    The aim of this study was to identify process indicators for the three phases of laboratory activity and their corresponding quality specifications in our setting (primary care centers, and second- and third-level hospitals that provide public healthcare services in Catalonia). Every 2 months, working group members met to present data obtained for quality indicators for the current processes in their laboratories. The results collected were for indicators recorded monthly from 2005 and for indicators recorded less frequently from 2004. The medians of the results obtained in all laboratories were calculated and the values obtained were established as the current specifications for the corresponding indicators. The laboratories participating in this working group use 12 indicators for the key processes (three for preanalytical steps, four for analytical steps and five for postanalytical steps). The preanalytical indicators are erroneous request, erroneous sample, and samples not taken, with specifications of 4.1%, 5.0% and 1.7%, respectively. A new indicator for the analytical step is the percentage of external controls exceeding the specification (0.8%); specifications for the other three well-recognized indicators (imprecision, bias and total error) are not the subject of this study. For the postanalytical phase, the indicators (and specifications) include duplicate hard copies of reports sent to centers or clinical units (1.6%), failure in critical value reporting (0.5%), reports exceeding delivery time (0.7%), reports from referred tests that exceed delivery time (8.9%), and incidents related to the data processing network between centers (25 events per year). The process indicators reflect the state-of-the-art of the laboratories comprising our working group. Current performance for the analytical phase is satisfactory because it is entirely in the hands of the laboratory, while the main problems in extra-analytical phases reside in activities performed outside

  5. A systematic review of diet quality indices in relation to obesity.

    Science.gov (United States)

    Asghari, Golaleh; Mirmiran, Parvin; Yuzbashian, Emad; Azizi, Fereidoun

    2017-04-01

    Tools, called 'diet/dietary quality indices', evaluate the level of adherence to a specified pattern or a set of recommendations in populations. Yet, there are no review studies providing unanimous comprehensive results of dietary indices on obesity. We reviewed observational studies, focusing on the association of diet quality indices with general obesity or abdominal obesity in adults. We systematically conducted a search in all English language publications available on MEDLINE, ISI Web of Science and Embase between January 1990 and January 2016. Among the wide variety of indices and weight-derived variables, studies with dietary-guideline-based indices and mean changes for weight gain or OR for general obesity and abdominal obesity were selected. From a total of 479 articles, thirty-four studies were selected for the current review, ten of which had prospective designs and twenty-six had cross-sectional designs. Associations of weight status with the original Healthy Eating Index (HEI) and other versions of the HEI including alternative HEI, HEI-2005 and HEI-05 were examined in thirteen studies, with ten studies revealing significant associations. The HEI was a better general obesity predictor in men than in women. Diet scores lacked efficacy in assessing overall diet quality and demonstrated no significant findings in developing countries, in comparison with US populations. In addition, indices based on dietary diversity scores were directly associated with weight gain. Despite the insufficient evidence to draw definitive conclusions about the relation between dietary indices and obesity, HEI was found to be inversely associated with obesity and diversity-based indices were positively associated with obesity.

  6. Protocol for a scoping review study to identify and classify patient-centred quality indicators.

    Science.gov (United States)

    Jolley, Rachel J; Lorenzetti, Diane L; Manalili, Kimberly; Lu, Mingshan; Quan, Hude; Santana, Maria J

    2017-01-05

    The concept of patient-centred care (PCC) is changing the way healthcare is understood, accepted and delivered. The Institute of Medicine has defined PCC as 1 of its 6 aims to improve healthcare quality. However, in Canada, there are currently no nationwide standards in place for measuring and evaluating healthcare from a patient-centred approach. In this paper, we outline our scoping review protocol to systematically review published and unpublished literature specific to patient-centred quality indicators that have been implemented and evaluated across various care settings. Arksey and O'Malley's scoping review methodology framework will guide the conduct of this scoping review. We will search electronic databases (MEDLINE, EMBASE, the Cochrane Library, Cumulative Index to Nursing and Allied Health Literature (CINAHL), PsycINFO, Social Work Abstracts, Social Services Abstracts), grey literature sources and the reference lists of key studies to identify studies appropriate for inclusion. 2 reviewers will independently screen all abstracts and full-text studies for inclusion. We will include any study which focuses on quality indicators in the context of PCC. All bibliographic data, study characteristics and indicators will be collected and analysed using a tool developed through an iterative process by the research team. Indicators will be classified according to a predefined conceptual framework and categorised and described using qualitative content analysis. The scoping review will synthesise patient-centred quality indicators and their characteristics as described in the literature. This review will be the first step to formally identify what quality indicators have been used to evaluate PCC across the healthcare continuum, and will be used to inform a stakeholder consensus process exploring the development of a generic set of patient-centred quality indicators applicable to multiple care settings. The results will be disseminated through a peer

  7. Long-term stability of beam quality and output of conventional X-ray units.

    Science.gov (United States)

    Fukuda, Atsushi; Matsubara, Kosuke; Miyati, Tosiaki

    2015-01-01

    Conventional diagnostic X-ray units are used for radiographic imaging in many countries. For obtaining entrance surface doses, a numerical dose determination method has been applied in Japan. Although this technique is effective, it has to account for errors, particularly fluctuations, due to the beam quality and output of X-ray tubes. As a part of our quality control procedures, we recorded the entrance surface air kerma, tube voltage, and half-value layer measurements made for four diagnostic X-ray tubes over a 103-week period. The entrance surface air kerma for one of the four X-ray tubes had increased significantly by 11.4 % over 1 year from its initial setting, whereas the tube voltages and half-value layers did not deviate significantly from their initial values. Medical physicists and radiological technologists should be aware of this fluctuation for diagnostic X-ray tubes and take it into consideration when calculating the entrance surface air kerma.

  8. Helium ion microscopy of graphene: beam damage, image quality and edge contrast

    Science.gov (United States)

    Fox, D.; Zhou, Y. B.; O'Neill, A.; Kumar, S.; Wang, J. J.; Coleman, J. N.; Duesberg, G. S.; Donegan, J. F.; Zhang, H. Z.

    2013-08-01

    A study to analyse beam damage, image quality and edge contrast in the helium ion microscope (HIM) has been undertaken. The sample investigated was graphene. Raman spectroscopy was used to quantify the disorder that can be introduced into the graphene as a function of helium ion dose. The effects of the dose on both freestanding and supported graphene were compared. These doses were then correlated directly to image quality by imaging graphene flakes at high magnification. It was found that a high magnification image with a good signal to noise ratio will introduce very significant sample damage. A safe imaging dose of the order of 1013 He+ cm-2 was established, with both graphene samples becoming highly defective at doses over 5 × 1014 He+ cm-2. The edge contrast of a freestanding graphene flake imaged in the HIM was then compared with the contrast of the same flake observed in a scanning electron microscope and a transmission electron microscope. Very strong edge sensitivity was observed in the HIM. This enhanced edge sensitivity over the other techniques investigated makes the HIM a powerful nanoscale dimensional metrology tool, with the capability of both fabricating and imaging features with sub-nanometre resolution.

  9. Evaluating Urban Quality: Indicators and Assessment Tools for Smart Sustainable Cities

    Directory of Open Access Journals (Sweden)

    Chiara Garau

    2018-02-01

    Full Text Available The analysis of urban sustainability is key to urban planning, and its usefulness extends to smart cities. Analyses of urban quality typically focus on applying methodologies that evaluate quality objectives at environmental, urban, and building levels. Research has shown that a system of indicators can be useful for developing qualitative and quantitative descriptors of urban environments. The first step in this study was to formulate a methodology to measure the quality of urban life based on investigative checklists and objective and subjective indicators, aggregated to develop an index to evaluate a city’s level of smart urban quality. The second step was to apply this methodology to evaluate the city of Cagliari (Italy at the neighbourhood scale, which is considered by literature the most suitable as a self-sufficient spatial unit for showing redevelopment results. In addition to sharing its research findings, this study aims to verify whether the methodology can be applied to similar urban contexts. The main outcomes of this research pertain to opportunities to numerically measure both objective and subjective aspects that affect urban quality. In this way, the most critical areas to be requalified have been highlighted in order to prepare policies congruent with the local context.

  10. Field Scale Studies on the Spatial Variability of Soil Quality Indicators in Washington State, USA

    Directory of Open Access Journals (Sweden)

    Jeffrey L. Smith

    2011-01-01

    Full Text Available Arable lands are needed for sustainable agricultural systems to support an ever-growing human population. Soil quality needs to be defined to assure that new land brought into crop production is sustainable. To evaluate soil quality, a number of soil attributes will need to be measured, evaluated, and integrated into a soil-quality index using the multivariable indicator kriging (MVIK procedure. This study was conducted to determine the spatial variability and correlation of indicator parameters on a field scale with respect to soil quality and suitability for use with MVIK. The variability of the biological parameters decreased in the order of respiration > enzyme assays and qCO2 > microbial biomass C. The distribution frequency of all parameters except respiration were normal although the spatial distribution across the landscape was highly variable. The biological parameters showed little correlation with each other when all data points were considered; however, when grouped in smaller sections, the correlations were more consistent with observed patterns across the field. To accurately assess soil quality, and arable land use, consideration of spatial and temporal variability, soil conditions, and other controlling factors must be taken into account.

  11. Comparing Effects of Forestland conversion to Tea Farming on Soil Quality Indices

    Science.gov (United States)

    Gholoubi, A.; Emami, H.; Alizadeh, A.; Jones, S. B.

    2017-12-01

    The effect of land use type on soil function within an ecosystem can be assessed and monitored using soil quality indices. The research examined effects of land use change from natural forest to tea farming (with the same physiography and parent materials) on soil properties in different regions of the Guilan province, northern Iran. Two universally-accepted methods of soil quality evaluation were used to understand soil conditions in these two land uses. Thirty-six soil samples (0 -30 cm) were randomly collected from six sites with 3 replications. The soil quality of forestland and tea farms was determined using the cumulative rating (CR) index and the Cornell Comprehensive Assessment of Soil Health (CASH) scoring functions. Effects of Land use change on soil quality or health were significant (P tea farm soils. forestland use affected most soil properties and thus their scores in both evaluation methods. Soil organic carbon and pH were the most important indicators reduced by land use change at all locations. There were significant correlations between these indicators and other soil chemical, physical and biological factors affected by changing forestland use.

  12. Malnutrition in Dutch health care: prevalence, prevention, treatment, and quality indicators.

    Science.gov (United States)

    Meijers, Judith M M; Halfens, Ruud J G; van Bokhorst-de van der Schueren, Marian A E; Dassen, Theo; Schols, Jos M G A

    2009-05-01

    In most health care organizations there is still insufficient awareness for recognizing and treating malnourished patients. To gain more insight into nutritional care policies in Dutch health care organizations, this study investigated screening, treatment, and other quality indicators of nutritional care. In 2007 a cross-sectional multicenter study was performed that included 20 255 patients (hospitals, n = 6021; nursing homes, n = 11 902; home care, n = 2332). A standardized questionnaire was used to study nutritional screening and treatment at the patient level and quality indicators at institutional and ward levels (e.g., malnutrition guidelines/protocols, nutritional education, and weighing policy). Nutritional screening was performed more often in nursing homes (60.2%) than in hospitals (40.3%) and home care (13.9%, P hospitals, and home care. At ward level nursing homes focused more on the quality of nutritional care than did hospitals and home care, especially with respect to controlling the use of nutritional guidelines (54.6%, P malnutrition is still a considerable problem in one of every five patients in all participating health care settings. It furthermore demonstrates that recognizing and treating malnutrition continues to be problematic. To target the problem of malnutrition adequately, more awareness is needed of the importance of nutritional screening, appropriate treatment, and other nutritional quality indicators.

  13. Measurements of kQ beam quality correction factors for the NE2611A chamber in high-energy photon beams using the NMi water calorimeter

    International Nuclear Information System (INIS)

    Pieksma, M.; Prez, L.A. de; Dijk, E. van; Aalbers, A.H.L.

    2002-01-01

    Full text: Recently published protocols for clinical reference dosimetry in external high-energy photon and electron beam radiotherapy by the AAPM and the IAEA are no longer based on traditional air-kerma standards, but have instead adopted absorbed dose to water as the key quantity. The most direct way to determine the absorbed dose to water is by employing a sealed-water type calorimeter. A number of national standards laboratories, among which the NMi, are presently conducting effort towards developing water calorimeters as the new standard for absorbed dose to water. The design of the NMi water calorimeter has several unique features. It is portable and compact, has radiation windows for both vertical and horizontal beams, and has a built-in waterproof ionization chamber, which can be used to determine experimental correction factors for the calorimeter lid, walls, etc. Thermistor probes operable at 4 deg. C are mounted in a sealed high-purity water cell. A high-quality water purifying system has been installed and integrated into a filling station for the water cell, including a bubbling stage to saturate the water with different gasses to control the well-known heat defect. A forthcoming revision of the NCS (Netherlands Commission on Radiation Dosimetry) protocols for dosimetry of high-energy photon and electron beams has direct relevance for the NMi water calorimeter. In accordance with the new AAPM and IAEA protocols, these revised protocols will also no longer be based on air kerma, but on absorbed dose to water instead. The NCS subcommittee 'Uniformity Dosimetry Protocols' is currently drafting new Codes of Practice for determining the absorbed dose to water for high-energy photon and electron beams used in radiotherapy institutes in the Netherlands and Belgium. Part of the new protocols will be a table of experimentally determined k Q beam quality correction factors for photon beam qualities and dosimetric equipment (graphite ionization chambers and

  14. Real-time determination of laser beam quality by modal decomposition.

    Science.gov (United States)

    Schmidt, Oliver A; Schulze, Christian; Flamm, Daniel; Brüning, Robert; Kaiser, Thomas; Schröter, Siegmund; Duparré, Michael

    2011-03-28

    We present a real-time method to determine the beam propagation ratio M2 of laser beams. The all-optical measurement of modal amplitudes yields M2 parameters conform to the ISO standard method. The experimental technique is simple and fast, which allows to investigate laser beams under conditions inaccessible to other methods.

  15. Dosimetric commissioning and quality assurance of scanned ion beams at the Italian National Center for Oncological Hadrontherapy

    Energy Technology Data Exchange (ETDEWEB)

    Mirandola, Alfredo, E-mail: mirandola@cnao.it; Molinelli, S.; Vilches Freixas, G.; Mairani, A.; Gallio, E.; Panizza, D.; Russo, S.; Ciocca, M. [Fondazione CNAO, strada Campeggi 53, Pavia 27100 (Italy); Donetti, M. [INFN, Torino 10125, Italy and Fondazione CNAO, strada Campeggi 53, Pavia 27100 (Italy); Magro, G. [INFN–Dipartimento di Fisica, Università degli Studi di Pavia, Via U. Bassi 6, Pavia 27100, Italy and Fondazione CNAO, strada Campeggi 53, Pavia 27100 (Italy); Giordanengo, S. [INFN, Torino 10125 (Italy); Orecchia, R. [Fondazione CNAO, strada Campeggi 53, Pavia 27100, Italy and Radiotherapy Division, European Institute of Oncology, Via Ripamonti 435, Milano 20141 (Italy)

    2015-09-15

    Purpose: To describe the dosimetric commissioning and quality assurance (QA) of the actively scanned proton and carbon ion beams at the Italian National Center for Oncological Hadrontherapy. Methods: The laterally integrated depth-dose-distributions (IDDs) were acquired with the PTW Peakfinder, a variable depth water column, equipped with two Bragg peak ionization chambers. FLUKA Monte Carlo code was used to generate the energy libraries, the IDDs in water, and the fragment spectra for carbon beams. EBT3 films were used for spot size measurements, beam position over the scan field, and homogeneity in 2D-fields. Beam monitor calibration was performed in terms of number of particles per monitor unit using both a Farmer-type and an Advanced Markus ionization chamber. The beam position at the isocenter, beam monitor calibration curve, dose constancy in the center of the spread-out-Bragg-peak, dose homogeneity in 2D-fields, beam energy, spot size, and spot position over the scan field are all checked on a daily basis for both protons and carbon ions and on all beam lines. Results: The simulated IDDs showed an excellent agreement with the measured experimental curves. The measured full width at half maximum (FWHM) of the pencil beam in air at the isocenter was energy-dependent for both particle species: in particular, for protons, the spot size ranged from 0.7 to 2.2 cm. For carbon ions, two sets of spot size are available: FWHM ranged from 0.4 to 0.8 cm (for the smaller spot size) and from 0.8 to 1.1 cm (for the larger one). The spot position was accurate to within ±1 mm over the whole 20 × 20 cm{sup 2} scan field; homogeneity in a uniform squared field was within ±5% for both particle types at any energy. QA results exceeding tolerance levels were rarely found. In the reporting period, the machine downtime was around 6%, of which 4.5% was due to planned maintenance shutdowns. Conclusions: After successful dosimetric beam commissioning, quality assurance measurements

  16. Quality Indicators to Assure and Improve Cancer Care in Spain Using the Delphi Technique.

    Science.gov (United States)

    Camps, Carlos; Albanell, Joan; Antón, Antonio; Aranda, Enrique; Carrato, Alfredo; Cassinello, Javier; Castellano, Daniel; Cruz, Juan J; Garrido, Pilar; Guillem, Vicente; Grávalos, Cristina; López, Guillermo; Llorente, César; Lorenzo, Antonio; Lluch, Ana; Ignacio, Emilio; Díaz-Rubio, Eduardo

    2016-05-01

    The quality of cancer care has become a priority for health care systems. The goal of this research was to develop a set of evidence-based quality indicators (QIs) for organization, palliative care, and colorectal, breast, and lung cancers for introducing a system of benchmarking in Spain. A comprehensive evidence-based literature search was performed to identify potential QIs. An expert panel (the health care quality promotion group) of 9 oncologists identified indicators and evaluated them. A Delphi process involving 58 physicians was used to rank QIs by clinical relevance (validity). The expert panel then evaluated the selected indicators in terms of the feasibility of measuring them in Spanish hospitals, their usefulness for comparisons, their degree of clinical relevance, and their sensitivity to the impact of health care improvements. From the literature review, 99 potential QIs were identified. The Delphi process shortened the list to 72 QIs. A final set of 57 QIs was established by the health care quality promotion group: 12 related to organizational issues, 11 to colorectal cancer, 11 to breast cancer, 12 to lung cancer, and 11 to palliative care. This final set included structure (n=2), process (n=36), and outcome (n=19) indicators. A set of QIs has been developed using a validated Delphi method, meaning that we can be confident of their validity, feasibility, sensitivity, and acceptability. These QIs are to serve as the basis of a strategy for benchmarking across oncology services in Spanish hospitals and should enable us to assure and improve the quality of cancer care. Copyright © 2016 by the National Comprehensive Cancer Network.

  17. Quality indicators for musculoskeletal injury management in the emergency department: a systematic review.

    Science.gov (United States)

    Strudwick, Kirsten; Nelson, Mark; Martin-Khan, Melinda; Bourke, Michael; Bell, Anthony; Russell, Trevor

    2015-02-01

    There is increasing importance placed on quality of health care for musculoskeletal injuries in emergency departments (EDs). This systematic review aimed to identify existing musculoskeletal quality indicators (QIs) developed for ED use and to critically evaluate their methodological quality. MEDLINE, EMBASE, CINAHL, and the gray literature, including relevant organizational websites, were searched in 2013. English-language articles were included that described the development of at least one QI related to the ED care of musculoskeletal injuries. Data extraction of each included article was conducted. A quality assessment was then performed by rating each relevant QI against the Appraisal of Indicators through Research and Evaluation (AIRE) Instrument. QIs with similar definitions were grouped together and categorized according to the health care quality frameworks of Donabedian and the Institute of Medicine. The search revealed 1,805 potentially relevant articles, of which 15 were finally included in the review. The number of relevant QIs per article ranged from one to 11, resulting in a total of 71 QIs overall. Pain (n = 17) and fracture management (n = 13) QIs were predominant. Ten QIs scored at least 50% across all AIRE Instrument domains, and these related to pain management and appropriate imaging of the spine. Methodological quality of the development of most QIs is poor. Recommendations for a core set of QIs that address the complete spectrum of musculoskeletal injury management in emergency medicine is not possible, and more work is needed. Currently, QIs with highest methodological quality are in the areas of pain management and medical imaging. © 2015 by the Society for Academic Emergency Medicine.

  18. Psychometric analysis of the TRANSIT quality indicators for cardiovascular disease prevention in primary care.

    Science.gov (United States)

    Khanji, Cynthia; Bareil, Céline; Hudon, Eveline; Goudreau, Johanne; Duhamel, Fabie; Lussier, Marie-Thérèse; Perreault, Sylvie; Lalonde, Gilles; Turcotte, Alain; Berbiche, Djamal; Martin, Élisabeth; Lévesque, Lise; Gagnon, Marie-Mireille; Lalonde, Lyne

    2017-12-01

    To assess a selection of psychometric properties of the TRANSIT indicators. Using medical records, indicators were documented retrospectively during the 14 months preceding the end of the TRANSIT study. Primary care in Quebec, Canada. Indicators were documented in a random subsample (n = 123 patients) of the TRANSIT study population (n = 759). For every patient, the mean compliance to all indicators of a category (subscale score) and to the complete set of indicators (overall scale score) were established. To evaluate test-retest and inter-rater reliabilities, indicators were applied twice, two months apart, by the same evaluator and independently by different evaluators, respectively. To evaluate convergent validity, correlations between TRANSIT indicators, Burge et al. indicators and Institut national d'excellence en santé et en services sociaux (INESSS) indicators were examined. Test-retest reliability, inter-rater reliability, and convergent validity. Test-retest reliability, as measured by intraclass correlation coefficients (ICCs) was equal to 0.99 (0.99-0.99) for the overall scale score while inter-rater reliability was equal to 0.95 (0.93-0.97) for the overall scale score. Convergent validity, as measured by Pearson's correlation coefficients, was equal to 0.77 (P TRANSIT indicators were compared to Burge et al. indicators and to 0.82 (P TRANSIT indicators were compared to INESSS indicators. Reliability was excellent except for eleven indicators while convergent validity was strong except for domains related to the management of CVD risk factors. © The Author 2017. Published by Oxford University Press in association with the International Society for Quality in Health Care. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  19. CRITERIA AND QUALITY INDICATORS OF INFORMATION AND COMMUNICATION TECHNOLOGIES OF LEARNING

    Directory of Open Access Journals (Sweden)

    Oleg M. Spirin

    2013-03-01

    Full Text Available In the article the concept of information and communication technology and information and communication technology of learning is specified. It is grounded an external and internal criteria of information and communication technologies of learning quality assessment based on experience of information and communication technology quality assessment of the methodical system of informatics teachers vocational training. There are considered the external indexes – design, structural, organizational, communicative and gnostic criteria, and internal – differentiation, individualization, intensification of teaching process and effectiveness of educational activity. There are presented the approaches to assess the indicators for determination of criteria demonstration degree.

  20. Turbidity as an Indicator of Water Quality in Diverse Watersheds of the Upper Pecos River Basin

    Directory of Open Access Journals (Sweden)

    Gregory M. Huey

    2010-06-01

    Full Text Available Microbial concentrations, total suspended solids (TSS and turbidity vary with stream hydrology and land use. Turbidity, TSS, and microbial concentrations, loads and yields from four watersheds were assessed: an unburned montane forest, a catastrophically burned montane forest, urban land use and rangeland prairie. Concentrations and loads for most water quality variables were greatest during storm events. Turbidity was an effective indicator of TSS, E. coli and Enterococci spp. The greatest threat to public health from microbial contamination occurs during storm runoff events. Efforts to manage surface runoff and erosion would likely improve water quality of the upper Pecos River basin in New Mexico, USA.

  1. 77 FR 40620 - AHRQ Workgroups on ICD-10-CM/PCS Conversion of Quality Indicators (QIs) - Extension Date for...

    Science.gov (United States)

    2012-07-10

    ..., patient safety, and/or clinical documentation improvement; --Familiarity with the AHRQ Quality Indicators... Indicators (PQI), the Inpatient Quality Indicators, the Patient Safety Indicators (PSI), and the Pediatric..., obstetrics and gynecologic disease, surgery, critical care and pulmonary disease, diabetes and endocrine...

  2. Use of cone beam computed tomography in implant dentistry: current concepts, indications and limitations for clinical practice and research.

    Science.gov (United States)

    Bornstein, Michael M; Horner, Keith; Jacobs, Reinhilde

    2017-02-01

    Diagnostic radiology is an essential component of treatment planning in the field of implant dentistry. This narrative review will present current concepts for the use of cone beam computed tomography imaging, before and after implant placement, in daily clinical practice and research. Guidelines for the selection of three-dimensional imaging will be discussed, and limitations will be highlighted. Current concepts of radiation dose optimization, including novel imaging modalities using low-dose protocols, will be presented. For preoperative cross-sectional imaging, data are still not available which demonstrate that cone beam computed tomography results in fewer intraoperative complications such as nerve damage or bleeding incidents, or that implants inserted using preoperative cone beam computed tomography data sets for planning purposes will exhibit higher survival or success rates. The use of cone beam computed tomography following the insertion of dental implants should be restricted to specific postoperative complications, such as damage of neurovascular structures or postoperative infections in relation to the maxillary sinus. Regarding peri-implantitis, the diagnosis and severity of the disease should be evaluated primarily based on clinical parameters and on radiological findings based on periapical radiographs (two dimensional). The use of cone beam computed tomography scans in clinical research might not yield any evident beneficial effect for the patient included. As many of the cone beam computed tomography scans performed for research have no direct therapeutic consequence, dose optimization measures should be implemented by using appropriate exposure parameters and by reducing the field of view to the actual region of interest. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Quality indicators in the treatment of patients with depression, bipolar disorder or schizophrenia. Consensus study.

    Science.gov (United States)

    Bernardo, Miquel; de Dios, Consuelo; Pérez, Víctor; Ignacio, Emilio; Serrano, Manuel; Vieta, Eduard; Mira, José Joaquín; Guilabert, Mercedes; Roca, Miquel

    To define a set of indicators for mental health care, monitoring quality assurance in schizophrenia, depression and bipolar disorders in Spain. Qualitative research. Consensus-based study involving 6 psychiatrists on the steering committee and a panel of 43 psychiatrists working in several health services in Spain. An initial proposal of 44 indicators for depression, 42 for schizophrenia and 58 for bipolar disorder was elaborated after reviewing the literature. This proposal was analysed by experts using the Delphi technique. The valuation of these indicators in successive rounds allowed those with less degree of consensus to be discarded. Feasibility, sensitivity and clinical relevance were considered. The study was carried out between July 2015 and March 2016. Seventy indicators were defined by consensus: 17 for major depression, 16 for schizophrenia, 17 for bipolar disorder and 20 common to all three pathologies. These indicators included measures related to adequacy, patient safety, exacerbation, mechanical restraint, suicidal behaviour, psychoeducation, adherence, mortality and physical health. This set of indicators allows quality monitoring in the treatment of patients with schizophrenia, depression or bipolar disorder. Mental health care authorities and professionals can use this proposal for developing a balanced scorecard adjusted to their priorities and welfare objectives. Copyright © 2017 SEP y SEPB. Publicado por Elsevier España, S.L.U. All rights reserved.

  4. Environmental indicator principium with case references to agricultural soil, water, and air qualities and model-derived indicators

    Science.gov (United States)

    Environmental indicators are powerful tools for tracking environmental changes, measuring environmental performance, and informing policy makers. With the ubiquitous nature of environmental assets and within the broad themes of environmental disciplines, many diverse environmental indicators, inclu...

  5. Reoperation for rhegmatogenous retinal detachment as quality indicator for disease management: a register study.

    Science.gov (United States)

    Hajari, Javad N; Christensen, Ulrik; Kiilgaard, Jens F; Bek, Toke; la Cour, Morten

    2015-09-01

    To establish a quality indicator that could be used in optimizing treatment for rhegmatogenous retinal detachment (RRD). The Danish National Patient Registry was used to identify surgery conducted in Denmark for RRD in the period 01 January 2001-31 December 2009. Cases were identified by diagnosis and surgical codes. A total of 6522 cases were operated for a primary RRD in the study period, and 22% (1434 patients) were reoperated for a redetachment. A Cox regression analysis showed that the risk of redetachment was equal to or less than detachment on the fellow eye 1 year after primary surgery with techniques not using silicone oil. The same was true 1.5 years after surgery for techniques using silicone oil. Based on this, we established a quality indicator defining failure as the need for operation for redetachment within 1 year from initial surgery when using techniques without oil and after 1.5 years for techniques using oil. Also the lack of oil removal within 1 year from initial surgery should be noted as an operational failure. We applied the quality indicators on the cohort of 6522 RRDs and found that in Denmark the need for redetachment surgery has decreased over time and also that high-volume departments have better outcome compared to smaller ones. The risk of reoperation for redetachment after initial surgery fulfils the criteria for a good quality indicator and can be used in RRD surgery. This indicator could aid in optimizing the management of RRD patients to minimize morbidity. © 2015 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  6. Stereotactic photon beam irradiation of uveal melanoma: indications and experience at the University of Vienna since 1997

    Energy Technology Data Exchange (ETDEWEB)

    Dieckmann, K.; Georg, D.; Rottenfusser, A.; Poetter, R. [Dept. of Radiotherapy, Univ. of Vienna (Austria); Zehetmayer, M. [Dept. of Ophthalmology, Univ. of Vienna (Austria)

    2007-12-15

    Most uveal melanomas are currently treated by eye-preserving radiotherapy. No advantage of enucleation of posterior uveal melanoma (< 12 mm) could be demonstrated in multiple studies (e.g.). Besides brachytherapy and highly conformal proton therapy advanced photon beam therapy techniques have been introduced during the last years. Since 1997, at the Medical University of Vienna, patients with uveal melanoma have been treated with 3D stereotactic photon beam radiotherapy. Special fixation- and eye-monitoring systems have been developed to perform a local treatment which provides high local tumor control with acceptable long term side effects. (orig.)

  7. Stereotactic photon beam irradiation of uveal melanoma: indications and experience at the University of Vienna since 1997

    International Nuclear Information System (INIS)

    Dieckmann, K.; Georg, D.; Rottenfusser, A.; Poetter, R.; Zehetmayer, M.

    2007-01-01

    Most uveal melanomas are currently treated by eye-preserving radiotherapy. No advantage of enucleation of posterior uveal melanoma (< 12 mm) could be demonstrated in multiple studies (e.g.). Besides brachytherapy and highly conformal proton therapy advanced photon beam therapy techniques have been introduced during the last years. Since 1997, at the Medical University of Vienna, patients with uveal melanoma have been treated with 3D stereotactic photon beam radiotherapy. Special fixation- and eye-monitoring systems have been developed to perform a local treatment which provides high local tumor control with acceptable long term side effects. (orig.)

  8. Quality and accuracy of cone beam computed tomography gated by active breathing control

    International Nuclear Information System (INIS)

    Thompson, Bria P.; Hugo, Geoffrey D.

    2008-01-01

    The purpose of this study was to evaluate the quality and accuracy of cone beam computed tomography (CBCT) gated by active breathing control (ABC), which may be useful for image guidance in the presence of respiration. Comparisons were made between conventional ABC-CBCT (stop and go), fast ABC-CBCT (a method to speed up the acquisition by slowing the gantry instead of stopping during free breathing), and free breathing respiration correlated CBCT. Image quality was assessed in phantom. Accuracy of reconstructed voxel intensity, uniformity, and root mean square error were evaluated. Registration accuracy (bony and soft tissue) was quantified with both an anthropomorphic and a quality assurance phantom. Gantry angle accuracy was measured with respect to gantry speed modulation. Conventional ABC-CBCT scan time ranged from 2.3 to 5.8 min. Fast ABC-CBCT scan time ranged from 1.4 to 1.8 min, and respiratory correlated CBCT scans took 2.1 min to complete. Voxel intensity value for ABC gated scans was accurate relative to a normal clinical scan with all projections. Uniformity and root mean square error performance degraded as the number of projections used in the reconstruction of the fast ABC-CBCT scans decreased (shortest breath hold, longest free breathing segment). Registration accuracy for small, large, and rotational corrections was within 1 mm and 1 degree sign . Gantry angle accuracy was within 1 degree sign for all scans. For high-contrast targets, performance for image-guidance purposes was similar for fast and conventional ABC-CBCT scans and respiration correlated CBCT.

  9. Development and validation of two phantoms for quality control in cone-beam CT

    International Nuclear Information System (INIS)

    Gomes B, W. O.

    2016-10-01

    The cone beam computed tomography (CBCT) was introduced into the market in the late 90 s and being a relatively new technology, also no well-established quality control protocols. There are currently projects to standardize the use of CBCT. The SEDENTEXCT project was created with the goal of developing guidelines for CBCT, including the development of a phantom for quality control it is proposed. This study aimed at the development and validation of the models of phantom: CQ I FBA 0 1 e CQ I FBA 0 2, the first filled with water and the second fully with solid structure in PMMA. Both models allow, otherwise the European phantom - SEDENTEXCT, its use in various models of CBCT, independent of the size of the field of view. The two phantoms used to evaluate seven parameters of quality control are: intensity or average value of pixels of five different plastics, signal to noise ratio, resolution, low contrast, spatial resolution, the accuracy of distances on the z axis, the geometric distortion and image uniformity. The spatial resolution is a critical parameter that differs significantly from the other types of scan, and in these two phantom can be evaluated by two different methods: MTF obtained by Fourier transformation of the function LSF (line spread function) and/or by analysis visual image to a pattern of bars up to 16 pl/cm. Validation was performed in three models CBCT: Kodak 9000, i-CAT Classical and Orthophos XG 3-dimensional. All imaging protocols were characterized dosimetric ally with solid state sensors to correlate with the perfect operation. These models were selected by different manufacturers have different characteristics as FOV, maximum voltage, slice thickness and patient positioning mode. The two of phantom models were viable and also showed compliance with the specifications and data available in the literature. We conclude the feasibility of the two phantom models, and model option will be linked to the practicality positioning equipment

  10. Regularization design for high-quality cone-beam CT of intracranial hemorrhage using statistical reconstruction

    Science.gov (United States)

    Dang, H.; Stayman, J. W.; Xu, J.; Sisniega, A.; Zbijewski, W.; Wang, X.; Foos, D. H.; Aygun, N.; Koliatsos, V. E.; Siewerdsen, J. H.

    2016-03-01

    Intracranial hemorrhage (ICH) is associated with pathologies such as hemorrhagic stroke and traumatic brain injury. Multi-detector CT is the current front-line imaging modality for detecting ICH (fresh blood contrast 40-80 HU, down to 1 mm). Flat-panel detector (FPD) cone-beam CT (CBCT) offers a potential alternative with a smaller scanner footprint, greater portability, and lower cost potentially well suited to deployment at the point of care outside standard diagnostic radiology and emergency room settings. Previous studies have suggested reliable detection of ICH down to 3 mm in CBCT using high-fidelity artifact correction and penalized weighted least-squared (PWLS) image reconstruction with a post-artifact-correction noise model. However, ICH reconstructed by traditional image regularization exhibits nonuniform spatial resolution and noise due to interaction between the statistical weights and regularization, which potentially degrades the detectability of ICH. In this work, we propose three regularization methods designed to overcome these challenges. The first two compute spatially varying certainty for uniform spatial resolution and noise, respectively. The third computes spatially varying regularization strength to achieve uniform "detectability," combining both spatial resolution and noise in a manner analogous to a delta-function detection task. Experiments were conducted on a CBCT test-bench, and image quality was evaluated for simulated ICH in different regions of an anthropomorphic head. The first two methods improved the uniformity in spatial resolution and noise compared to traditional regularization. The third exhibited the highest uniformity in detectability among all methods and best overall image quality. The proposed regularization provides a valuable means to achieve uniform image quality in CBCT of ICH and is being incorporated in a CBCT prototype for ICH imaging.

  11. Compliance with quality prescribing indicators in terms of their relationship to financial incentives.

    Science.gov (United States)

    Fernández Urrusuno, Rocío; Montero Balosa, Ma Carmen; Pérez Pérez, Pastora; Pascual de la Pisa, Beatriz

    2013-10-01

    To develop quality prescribing indicators for general practitioners (GPs) who are non-monitored and not included in pay-for-performance programs, and to determine compliance with incentivized and non-incentivized indicators. Descriptive cross sectional study. Aljarafe Primary Health Care Area (Andalusian Public Health Care Service, Spain), a rural and suburban area with a population of 323,857 inhabitants. Health assistance in this area is provided by 176 GPs in 37 health centers. Prescribing indicators were developed by a multidisciplinary group using a qualitative technique based on consensus. The members of the consensus group searched for updated recommendations focused on clinical evidence. Prescribing data were obtained from the computerised pharmacy records of reimbursed drugs and clinical data from the electronic clinical databases and hospital admission records. Fourteen indicators based on the selection of drugs of different therapeutic groups or linked to patient´s clinical information were designed. The compliance with indicators based on the selection of drugs linked to financial incentives was higher than that of indicators not linked to financial incentives. The compliance with indicators based on clinical information varied widely. Inappropriate prescribing ranged from 7 %, in the use of long-acting beta-agonists in asthma, to 86 % in the use of drugs for the prevention of osteoporotic fractures in young women. This study shows better compliance by GPs with indirect and incentivized quality prescribing indicators, included in pay-for-performance programs, compared with not-incentivized indicators based on the relative use of drugs and on the appropriateness prescribing.

  12. The Psychometric Properties and the Development of the Indicators of Quality Nursing Work Environments in Taiwan.

    Science.gov (United States)

    Lin, Chiou-Fen; Lu, Meei-Shiow; Huang, Hsiu-Ying

    2016-03-01

    The nursing shortage in medical institutions in Taiwan averaged 9% in 2012, considerably higher than the 5% indicated in the literature. As a result, many hospitals have been forced to close wards or reduce beds. Despite the acute need, the percentage of registered nurses who are employed as nurses in Taiwan (60.4%) is considerably lower than those in Canada or the United States. This low rate may be because of the poor working environment for nurses in Taiwan. This study aimed to develop a set of nursing work environment quality indicators for Taiwan and to test the reliability and validity of the resulting survey tool. Multiple methods were used in this study. In Phase 1, we organized an expert panel, reviewed the literature, and conducted seven rounds of expert panel discussion and six focus group discussions with nursing directors. The goal was to draft indicators representing a quality nursing work environment to fit current conditions in Taiwan. In Phase 2, we conducted an expert review for content validity, held three public hearings, and conducted a survey. Four hundred twenty-seven questionnaires were sent out, with 381 returned. The goal was to test the content validity, construct validity, and internal consistency reliability. The study produced a set of indicators of a quality nursing work environment with eight dimensions and 65 items. The content validity index for importance and suitability dimensions were 1.0, whereas the internal consistency was 0.91. The eight dimensions were safe practice environment (16 items), quality and quantity of staff (four items), salary and welfare (seven items), professional specialization and teamwork (seven items), work simplification (five items), informatics (five items), career development (nine items), and support and caring (12 items). The overall load for the indicators was 77.57%. The developed indicators may be used to evaluate the quality of nursing work environments. Furthermore, the indicators may be used

  13. Correction factors for photon beam quality for cylindrical ionization chambers: Monte Carlo calculations by using the PENELOPE code

    International Nuclear Information System (INIS)

    Barreras Caballero, A. A.; Hernandez Garcia, J.J.; Alfonso Laguardia, R.

    2009-01-01

    Were directly determined correction factors depending on the type camera beam quality, k, Q, and kQ, Qo, instead of the product (w, air p) Q, for three type cylindrical ionization chambers Pinpoint and divergent monoenergetic beams of photons in a wide range of energies (4-20 MV). The method of calculation used dispenses with the approaches taken in the classic procedure considered independent of braking power ratios and the factors disturbance of the camera. A detailed description of the geometry and materials chambers were supplied by the manufacturer and used as data input for the system 2006 of PENELOPE Monte Carlo calculation using a User code that includes correlated sampling, and forced interactions division of particles. We used a photon beam Co-60 as beam reference for calculating the correction factors for beam quality. No data exist for the cameras PTW 31014, 31015 and 31016 in the TRS-398 at they do not compare the results with data calculated or determined experimentally by other authors. (author)

  14. Quality control of radiotherapy centres in the Slovak Republic: a dosimetry intercomparison of photon and electron beams under reference conditions

    International Nuclear Information System (INIS)

    Gomola, I.; Kralik, G.; Laginova, V.; Van Dam, J.

    2001-01-01

    The aim of this paper is a dosimetry intercomparison of photon and electron beams under reference conditions as well as quality control of radiotherapy centres in the Slovak Republic. The results obtained in the first check shows that only about 60% of beams are within the acceptance limit. The reasons of discrepancies were traced, in some cases by an on site visit of experts from the NRC, and unacceptable deviations were corrected. The results clearly demonstrate the usefulness of the external dosimetry checks performed with the mailed thermoluminescent dosimeters. Standard deviation of the distribution of the results decreased from SD=4.3% to SD=I.8% for checked photon beams and from SD=8.6% to SD=2.4% for electron beams, respectively, at the end of the project. The dosimetry audits which are performed in regular intervals significantly decreasing a possibility of mistreatment (under-dosage or over-dosage ) of patients due to wrong calibration of radiation therapy beams. In order to keep the reached level of dosimetry precision, it is necessary to establish the external audit in radiotherapy at the national level based on postal TLD dosimetry by transferring the know-how from the international program on quality assurance in radiotherapy dosimetry with the assistance of the IAEA. (authors)

  15. Simulation study of the photon quality correction factors of ionization chambers for FiR 1 epithermal neutron beam

    International Nuclear Information System (INIS)

    Koivunoro, H.; Uusi-Simola, J.; Savolainen, S.; Kotiluoto, P.; Auterinen, I.; Kosunen, A.

    2006-01-01

    At FiR 1 BNCT facility in Finland, neutron-insensitive Mg(Ar) ionization chambers are used for photon dose measurements in an epithermal neutron beam. Previously, photon sensitivity factors for the chamber for the measurements in a water phantom in FiR 1 beam have been determined experimentally from measurements in 60 Co gamma and in a 6 MV clinical accelerator photon beams. However, the response of the ionization chamber in a water phantom depends on energy spectrum and angle of the photons and the secondary electrons created inside the phantom and may differ depending on type of the irradiation source (accelerator vs. an epithermal neutron beam). Also, the experimental sensitivity factor does not take into account the possible perturbations in the photon production in phantom caused by the ionization chamber materials. Therefore, it is necessary to determine the photon quality correction factors (k Qγ ) for the Mg(Ar) chamber at the FiR 1 beam through computer simulations. In this study, the k Qγ factors have been determined for Mg(Ar) chamber from Monte Carlo calculations of absorbed photon dose at two depths in a water phantom using MCNP code. The k qγ factors obtained with this method are compared to the sensitivity factors determined with measurements in an accelerator photon beam and to the k Qγ factors published previously. (author)

  16. The effect of thermal de-phasing on the beam quality of a high-power single-pass second harmonic generation

    Science.gov (United States)

    Sadat Hashemi, Somayeh; Ghavami Sabouri, Saeed; Khorsandi, Alireza

    2018-04-01

    We present a theoretical model in order to study the effect of a thermally loaded crystal on the quality of a second-harmonic (SH) beam generated in a high-power pumping regime. The model is provided based on using a particular structure of oven considered for MgO:PPsLT nonlinear crystal to compensate for the thermal de-phasing effect that as the pumping power reaches up to 50 W degrades the conversion efficiency and beam quality of the interacting beams. Hereupon, the quality of fundamental beam is involved in the modeling to investigate the final effect on the beam quality of generated SH beam. Beam quality evaluation is subsequently simulated using Hermite–Gaussian modal decomposition approach for a range of fundamental beam qualities varied from 1 to 3 and for different levels of input powers. To provide a meaningful comparison numerical simulation is correlated with real data deduced from a high-power SH generation (SHG) experimental device. It is found that when using the open-top oven scheme and fixing the fundamental M 2-factor at nearly 1, for a range of input powers changing from 15 to 30 W, the M 2-factor of SHG beam is degraded from 9% to 24%, respectively, confirming very good consistency with the reported experimental results.

  17. Improving Indicators in a Brazilian Hospital Through Quality-Improvement Programs Based on STS Database Reports

    Directory of Open Access Journals (Sweden)

    Pedro Gabriel Melo de Barros e Silva

    2015-12-01

    Full Text Available ABSTRACT OBJECTIVE: To report the initial changes after quality-improvement programs based on STS-database in a Brazilian hospital. METHODS: Since 2011 a Brazilian hospital has joined STS-Database and in 2012 multifaceted actions based on STS reports were implemented aiming reductions in the time of mechanical ventilation and in the intensive care stay and also improvements in evidence-based perioperative therapies among patients who underwent coronary artery bypass graft surgeries. RESULTS: All the 947 patients submitted to coronary artery bypass graft surgeries from July 2011 to June 2014 were analyzed and there was an improvement in all the three target endpoints after the implementation of the quality-improvement program but the reduction in time on mechanical ventilation was not statistically significant after adjusting for prognostic characteristics. CONCLUSION: The initial experience with STS registry in a Brazilian hospital was associated with improvement in most of targeted quality-indicators.

  18. Are Front of Pack Claims Indicators of Nutrition Quality? Evidence from 2 Product Categories.

    Science.gov (United States)

    Schaefer, Debra; Hooker, Neal H; Stanton, John L

    2016-01-01

    American grocery shoppers face an array of front of pack (FOP) nutrition and health claims when making food selections. Such systems have been categorized as summary or nutrient specific. Either type should help consumers make judgments about the nutrition quality of a product. This research tests if the type or quantity of FOP claims are indeed good indicators of objective nutrition quality. Claim and nutrition information from more than 2200 breakfast cereals and prepared meals launched between 2006 and 2010 were analyzed using binary and multinomial logistic regression models. Results suggest that no type or number of front of pack claims could distinguish "healthy" foods. However, some types and frequencies of FOP claims were significant predictors of higher or lower levels of certain key nutrients. Given the complex and crowded label environment in which these FOP claims reside, one may be concerned that such cues are not closely related to objective measures of nutrition quality. © 2015 Institute of Food Technologists®

  19. Quality indicators of preventable adverse drug events in patients with type 2 diabetes

    DEFF Research Database (Denmark)

    Thomsen, Linda Aagaard

    population receiving oral antihyperglycaemic treatment (9,791 persons) was set up, and indicator positives identified (Articles no. 2 and 3). The third step in the model consisted of a risk assessment of preventable adverse drug events, including an assessment of clinical areas that need quality improvement...... events are common in primary care, with many resulting in hospitalisation. Projected to a Danish setting, 216,000 patients will experience a preventable adverse drug event each year, and 162,000 of these patients will need hospital admission. Quality improvement interventions should target errors......Summary Background: Preventable adverse drug events are caused by errors in the medication use Preventable adverse drug events are caused by errors in the medication use process, and are of particular interest when designing interventions to improve the quality of medication therapy. Type 2...

  20. Quality of life and physical activity as indicators of health-preserving competence of teachers

    Directory of Open Access Journals (Sweden)

    Pavlova Iu.A.

    2012-03-01

    Full Text Available The quality of life and physical activity of teachers of physical culture, basic of health, labour, the defense of Motherland and pedagogue-organizers from secondary schools Lviv region (Ukraine were investigated. The 402 persons (age 24-78 years were surveyed with the use of questionnaires MOS SF 36 and IPAQ. The highest quality of life and level of physical activity have teachers of physical culture. It is considered the quality of life of teachers of other subjects similar to persons with chronic diseases. The level of physical activity in leisure time was particularly low for teachers of Basic of Health and pedagogue-organizers. The teachers spent no more than 433 MET-min/ week for moderate- and vigorous-intensity activity. The level of physical activity of teachers (besides the physical education teachers was insufficient to improve health and indicate about low level of health-preserving competence.

  1. Quality Indicators of End-of-Life Care in Patients With Cancer: What Rate Is Right?

    Science.gov (United States)

    Barbera, Lisa; Seow, Hsien; Sutradhar, Rinku; Chu, Anna; Burge, Fred; Fassbender, Konrad; McGrail, Kim; Lawson, Beverley; Liu, Ying; Pataky, Reka; Potapov, Alex

    2015-05-01

    To develop data-driven and achievable benchmark rates for end-of-life quality indicators using administrative data from four provinces in Canada. Indicators of end-of-life care were defined and measured using linked administrative data for 33 health regions across British Columbia, Alberta, Ontario, and Nova Scotia. These were emergency department use, intensive care unit admission, physician house calls and home care visits before death, and death in hospital. An empiric benchmark was defined using indicator rates from the top-ranked regions to include the top decile of patients overall. Funnel plots were used to graph each region's age- and sex-adjusted indicator rates along with the overall rate and 95% confidence limits. Rates varied approximately two- to four-fold across the regions, with physician house calls showing the greatest variation. Benchmark rates based on the top decile performers were emergency department use, 34%; intensive care unit admission, 2%; physician house calls, 34%; home care visits, 63%; and death in hospital, 38%. With the exception of intensive care unit admission, funnel plots demonstrated that overall indicator rates and their confidence limits were uniformly worse than benchmarks even after adjusting for age and sex. Few regions met the benchmark rates. There is significant variation in end-of-life quality indicators across regions in four provinces in Canada. Using this study's methods-deriving empiric benchmarks and funnel plots-regions can determine their relative performance with greater context that facilitates priority setting and resource deployment. Applying this study's methods can support quality improvement by decreasing variation and striving for a target. Copyright © 2015 by American Society of Clinical Oncology.

  2. SU-E-I-59: Image Quality and Dose Measurement for Partial Cone-Beam CT

    Energy Technology Data Exchange (ETDEWEB)

    Abouei, E; Ford, N [University of British Columbia, Vancouver, BC (Canada)

    2014-06-01

    Purpose: To characterize performance of cone beam CT (CBCT) used in dentistry investigating quantitatively the image quality and radiation dose during dental CBCT over different settings for partial rotation of the x-ray tube. Methods: Image quality and dose measurements were done on a variable field of view (FOV) dental CBCT (Carestream 9300). X-ray parameters for clinical settings were adjustable for 2–10 mA, 60–90 kVp, and two optional voxel size values, but time was fixed for each FOV. Image quality was assessed by scanning cylindrical poly-methyl methacrylate (PMMA) image quality phantom (SEDENTEXCT IQ), and then the images were analyzed using ImageJ to calculate image quality parameters such as noise, uniformity, and contrast to noise ratio (CNR). A protocol proposed by SEDENTEXCT, dose index 1 (DI1), was applied to dose measurements obtained using a thimble ionization chamber and cylindrical PMMA dose index phantom (SEDENTEXCT DI). Dose distributions were obtained using Gafchromic film. The phantoms were positioned in the FOV to imitate a clinical positioning. Results: The image noise was 6–12.5% which, when normalized to the difference of mean voxel value of PMMA and air, was comparable between different FOVs. Uniformity was 93.5ß 99.7% across the images. CNR was 1.7–4.2 and 6.3–14.3 for LDPE and Aluminum, respectively. Dose distributions were symmetric about the rotation angle's bisector. For large and medium FOVs at 4 mA and 80–90 kVp, DI1 values were in the range of 1.26–3.23 mGy. DI1 values were between 1.01–1.93 mGy for small FOV (5×5 cm{sup 2}) at 4–5 mA and 75–84 kVp. Conclusion: Noise decreased by increasing kVp, and the CNR increased for each FOV. When FOV size increased, image noise increased and CNR decreased. DI1 values were increased by increasing tube current (mA), tube voltage (kVp), and/or FOV. Funding for this project from NSERC Discovery grant, UBC Faculty of Dentistry Research Equipment Grant and UBC Faculty of

  3. A quality assurance framework for the fully automated and objective evaluation of image quality in cone-beam computed tomography.

    Science.gov (United States)

    Steiding, Christian; Kolditz, Daniel; Kalender, Willi A

    2014-03-01

    Thousands of cone-beam computed tomography (CBCT) scanners for vascular, maxillofacial, neurological, and body imaging are in clinical use today, but there is no consensus on uniform acceptance and constancy testing for image quality (IQ) and dose yet. The authors developed a quality assurance (QA) framework for fully automated and time-efficient performance evaluation of these systems. In addition, the dependence of objective Fourier-based IQ metrics on direction and position in 3D volumes was investigated for CBCT. The authors designed a dedicated QA phantom 10 cm in length consisting of five compartments, each with a diameter of 10 cm, and an optional extension ring 16 cm in diameter. A homogeneous section of water-equivalent material allows measuring CT value accuracy, image noise and uniformity, and multidimensional global and local noise power spectra (NPS). For the quantitative determination of 3D high-contrast spatial resolution, the modulation transfer function (MTF) of centrally and peripherally positioned aluminum spheres was computed from edge profiles. Additional in-plane and axial resolution patterns were used to assess resolution qualitatively. The characterization of low-contrast detectability as well as CT value linearity and artifact behavior was tested by utilizing sections with soft-tissue-equivalent and metallic inserts. For an automated QA procedure, a phantom detection algorithm was implemented. All tests used in the dedicated QA program were initially verified in simulation studies and experimentally confirmed on a clinical dental CBCT system. The automated IQ evaluation of volume data sets of the dental CBCT system was achieved with the proposed phantom requiring only one scan for the determination of all desired parameters. Typically, less than 5 min were needed for phantom set-up, scanning, and data analysis. Quantitative evaluation of system performance over time by comparison to previous examinations was also verified. The maximum

  4. A quality assurance framework for the fully automated and objective evaluation of image quality in cone-beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Steiding, Christian; Kolditz, Daniel; Kalender, Willi A., E-mail: willi.kalender@imp.uni-erlangen.de [Institute of Medical Physics, University of Erlangen-Nürnberg, Henkestraße 91, 91052 Erlangen, Germany and CT Imaging GmbH, 91052 Erlangen (Germany)

    2014-03-15

    Purpose: Thousands of cone-beam computed tomography (CBCT) scanners for vascular, maxillofacial, neurological, and body imaging are in clinical use today, but there is no consensus on uniform acceptance and constancy testing for image quality (IQ) and dose yet. The authors developed a quality assurance (QA) framework for fully automated and time-efficient performance evaluation of these systems. In addition,