WorldWideScience

Sample records for beam deflection measurement

  1. Towards a mechanistic analysis of Benkelman beam deflection measurements

    NARCIS (Netherlands)

    Visser, A.F.H.M.; Priambodo Koesrindartono, D.

    2000-01-01

    This paper introduces and describes the Benkelman beam deflection test. Furthermore Benkelman beam tests are simulated using two multi-layer programs, based on an elastic and visco-elastic material model for asphalt. The results of these two programs are compared with each other. Finally, using the

  2. Direct measurement of the beam deflection angle using the axial B-dot field

    Directory of Open Access Journals (Sweden)

    Xiaozhong He

    2011-05-01

    Full Text Available Beam position monitors are an important diagnostics tool for particle accelerator operation and related beam dynamics research. The measurement of the beam deflection angle, or moving direction of a charged particle beam with respect to the beam pipe axis, can provide useful additional information. Beam monitors sensitive to the beam’s azimuthal B-dot field (sometimes referred as B dots are used to measure the displacement (position of the beam centroid, as the beam generates a dipole term of the azimuthal magnetic field. Similarly, a dipole term of the axial magnetic field will be generated by the beam moving in a direction not parallel to the axis of the beam pipe. In this paper, a new method using the axial B-dot field is presented to measure the beam deflection angle directly, including the theoretical background. Simulations using the MAFIA numerical code have been performed, demonstrating a good agreement to the new established analytical model.

  3. Measurement of ultra-low ion energy of decelerated ion beam using a deflecting electric field

    Energy Technology Data Exchange (ETDEWEB)

    Thopan, P.; Suwannakachorn, D.; Tippawan, U. [Plasma and Beam Physics Research Facility, Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Yu, L.D., E-mail: yuld@thep-center.org [Plasma and Beam Physics Research Facility, Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Thailand Center of Excellence in Physics, Commission on Higher Education, 328 Si Ayutthaya Road, Bangkok 10400 (Thailand)

    2015-12-15

    In investigation on ultra-low-energy ion bombardment effect on DNA, an ion beam deceleration lens was developed for high-quality ultra-low-energy ion beam. Measurement of the ion energy after deceleration was necessary to confirm the ion beam really decelerated as theoretically predicted. In contrast to conventional methods, this work used a simple deflecting electrostatic field after the deceleration lens to bend the ion beam. The beam bending distance depended on the ion energy and was described and simulated. A system for the measurement of the ion beam energy was constructed. It consisted of a pair of parallel electrode plates to generate the deflecting electrical field, a copper rod measurement piece to detect ion beam current, a vernier caliper to mark the beam position, a stepping motor to translate the measurement rod, and a webcam-camera to read the beam bending distance. The entire system was installed after the ion-beam deceleration lens inside the large chamber of the bioengineering vertical ion beam line. Moving the measurement rod across the decelerated ion beam enabled to obtain beam profiles, from which the beam bending distance could be known and the ion beam energy could be calculated. The measurement results were in good agreement with theoretical and simulated results.

  4. Measurement of ultra-low ion energy of decelerated ion beam using a deflecting electric field

    Science.gov (United States)

    Thopan, P.; Suwannakachorn, D.; Tippawan, U.; Yu, L. D.

    2015-12-01

    In investigation on ultra-low-energy ion bombardment effect on DNA, an ion beam deceleration lens was developed for high-quality ultra-low-energy ion beam. Measurement of the ion energy after deceleration was necessary to confirm the ion beam really decelerated as theoretically predicted. In contrast to conventional methods, this work used a simple deflecting electrostatic field after the deceleration lens to bend the ion beam. The beam bending distance depended on the ion energy and was described and simulated. A system for the measurement of the ion beam energy was constructed. It consisted of a pair of parallel electrode plates to generate the deflecting electrical field, a copper rod measurement piece to detect ion beam current, a vernier caliper to mark the beam position, a stepping motor to translate the measurement rod, and a webcam-camera to read the beam bending distance. The entire system was installed after the ion-beam deceleration lens inside the large chamber of the bioengineering vertical ion beam line. Moving the measurement rod across the decelerated ion beam enabled to obtain beam profiles, from which the beam bending distance could be known and the ion beam energy could be calculated. The measurement results were in good agreement with theoretical and simulated results.

  5. Systematic characterization of optical beam deflection measurement system for micro and nanomechanical systems

    NARCIS (Netherlands)

    Herfst, R.W.; Klop, W.A.; Eschen, M.; Dool, T.C. van den; Koster, N.B.; Sadeghian Marnani, H.

    2014-01-01

    Optical beam deflection (OBD) measurement method is very popular in various types of scanning probe microscopy (SPM) and micro/nanomechanical sensors to measure a mechanical motion. This paper reports the detail design and implementation of a very low drift (2 nm over 1000 s), high bandwidth (40 MHz

  6. Systematic characterization of optical beam deflection measurement system for micro and nanomechanical systems

    NARCIS (Netherlands)

    Herfst, R.W.; Klop, W.A.; Eschen, M.; Dool, T.C. van den; Koster, N.B.; Sadeghian Marnani, H.

    2014-01-01

    Optical beam deflection (OBD) measurement method is very popular in various types of scanning probe microscopy (SPM) and micro/nanomechanical sensors to measure a mechanical motion. This paper reports the detail design and implementation of a very low drift (2 nm over 1000 s), high bandwidth (40

  7. Vertical dynamic deflection measurement in concrete beams with the Microsoft Kinect.

    Science.gov (United States)

    Qi, Xiaojuan; Lichti, Derek; El-Badry, Mamdouh; Chow, Jacky; Ang, Kathleen

    2014-02-19

    The Microsoft Kinect is arguably the most popular RGB-D camera currently on the market, partially due to its low cost. It offers many advantages for the measurement of dynamic phenomena since it can directly measure three-dimensional coordinates of objects at video frame rate using a single sensor. This paper presents the results of an investigation into the development of a Microsoft Kinect-based system for measuring the deflection of reinforced concrete beams subjected to cyclic loads. New segmentation methods for object extraction from the Kinect's depth imagery and vertical displacement reconstruction algorithms have been developed and implemented to reconstruct the time-dependent displacement of concrete beams tested in laboratory conditions. The results demonstrate that the amplitude and frequency of the vertical displacements can be reconstructed with submillimetre and milliHz-level precision and accuracy, respectively.

  8. Measurement of Deflection in Concrete Beams During Fatigue Loading Test Using the Microsoft Kinect 2.0

    Science.gov (United States)

    Lahamy, Herve; Lichti, Derek D.; Steward, Jeremy; El-Badry, Mamdouh; Moravvej, Mohammad

    2016-03-01

    This study focuses on 3 Hz fatigue load testing of a reinforced concrete beam in laboratory conditions. Three-dimensional (3D) image time series of the beam's top surface were captured with the Microsoft time-of-flight Kinect 2.0 sensor. To estimate the beam deflection, the imagery was first segmented to extract the top surface of the beam. The centre line was then modeled using third-order B-splines. The deflection of the beam as a function of time was estimated from the modeled centre line and, following past practice, also at several witness plates attached to the side of the beam. Subsequent correlation of the peak displacement with the applied loading cycles permitted estimation of fatigue in the beam. The accuracy of the deflections was evaluated by comparison with the measurements obtained using a Keyence LK-G407 laser displacement sensors. The results indicate that the deflections can be recovered with sub-millimetre accuracy using the centreline profile modelling method.

  9. Three-dimensional thermal-conductivity-tensor measurement of a polymer crystal by photothermal probe-beam deflection

    Science.gov (United States)

    Quelin, Xavier; Perrin, Bernard; Louis, Gérard; Peretti, Pierre

    1993-08-01

    Using Fourier transforms we have calculated the solutions of the three-dimensional (3D) thermal-conduction equation in an anisotropic medium. The temperature distribution at the surface of the sample and a 3D thermal-conductivity tensor is measured by the photothermal-probe-beam-deflection technique. We show that the expression for the deflection angle can be the same as in an isotropic medium, provided that an effective thermal conductivity relative to the polymeric-chain axis and a rescaled sample thickness are considered. This theoretical model is found to be in good agreement with the experimental data for an orthorhombic polydiacetylene sample (4BCMU).

  10. Deflection of elastic beam with SMA wires eccentrically inserted

    Science.gov (United States)

    Jamian, S.; Nik Mohamed, N. A.; Ihsan, A. K. A. Mohd; Ismail, A. E.; Nor, M. K. Mohd; Kamarudin, K. A.; Nor, N. H. Muhd

    2017-08-01

    This research is intended to investigate the ability of shape memory alloys (SMA), through its activation, in generating loads to control beam deflection. An elastic beam is formed by sandwiching eccentrically SMA wires between two elastic plates. SMA wires are activated by electrical current from the power supply. Laser displacement meter (LDM) is used to measures deflection of sample. Results show that the deflection of the beam is dependent on the temperature change. The temperature-deflection response also shows the existence of hysteresis.

  11. Linearizing Intra-Train Beam-Beam Deflection Feedback

    Energy Technology Data Exchange (ETDEWEB)

    Smith, S.R.; /SLAC

    2006-02-22

    Beam-beam deflection feedback acting within the crossing time of a single bunch train may be needed to keep linear collider beams colliding at high luminosity. In a short-pulse machine such as the Next Linear Collider (NLC) this feedback must converge quickly to be useful. The non-linear nature of beam-beam deflection vs. beam-beam offset in these machines precludes obtaining both rapid convergence and a stable steady-state lock to beam offsets with a linear feedback algorithm. We show that a simply realizable programmable non-linear amplifier in the feedback loop can linearize the feedback loop, approximately compensating the beam-beam deflection non-linearity. Performance of a prototype non-linear amplifier is shown. Improvement of convergence and stability of the beam-beam feedback loop is simulated.

  12. Observation of Beam-beam Deflections with LHC Orbit Data

    CERN Document Server

    Kozanecki, W; Wenninger, J

    2013-01-01

    The LHC luminosity is calibrated in dedicated fills with van der Meer scans (vdM) of the beams that are performed repeatedly in both planes. During vdM scans the relative separation of the two LHC beams is scanned in a range of ±6 sigma , where sigma is the single beam size, probing the beam-beam deflection over a relatively large range. Orbit data logged parasitically during those scans were analysed and the beam-beam deflections at the IP being scanned could be reconstructed from orbit fits in the LHC arcs surrounding the IP. Despite the small size of the kicks (≤ 1μrad) the coherent beam-beam deflections are clearly resolved. The beam parameters that are extracted from the fit to the beam-beam deflection data were compared to luminosity data fits and they were found to be in good agreement. The closed orbit shift due to the beam-beam kick is also clearly observed in the beam position interpolation at the collision point.

  13. Optimized frequency dependent photothermal beam deflection spectroscopy

    Science.gov (United States)

    Korte, D.; Cabrera, H.; Toro, J.; Grima, P.; Leal, C.; Villabona, A.; Franko, M.

    2016-12-01

    In the letter the optimization of the experimental setup for photothermal beam deflection spectroscopy is performed by analyzing the influence of its geometrical parameters (detector and sample position, probe beam radius and its waist position etc) on the detected signal. Furthermore, the effects of the fluid’s thermo-optical properties, for optimized geometrical configuration, on the measurement sensitivity and uncertainty determination of sample thermal properties is also studied. The examined sample is a recently developed CuFeInTe3 material. It is seen from the obtained results, that it is a complex problem to choose the proper geometrical configuration as well as sensing fluid to enhance the sensitivity of the method. A signal enhancement is observed at low modulation frequencies by placing the sample in acetonitrile (ACN), while at high modulation frequencies the sensitivity is higher for measurements made in air. For both, detection in air and acetonitrile the determination of CuFeInTe3 thermal properties is performed. The determined values of thermal diffusivity and thermal conductivity are (0.048  ±  0.002)  ×  10-4 m2 s-1 and 4.6  ±  0.2 W m-1 K-1 and (0.056  ±  0.005)  ×  10-4 m2 s-1 and 4.8  ±  0.4 W m-1 K-1 for ACN and air, respectively. It is seen, that the determined values agree well within the range of their measurement uncertainties for both cases, although the measurement uncertainty is two times lower for the measurements in ACN providing more accurate results. The analysis is performed by the use of recently developed theoretical description based on the complex geometrical optics. It is also shown, how the presented work fits into the current status of photothermal beam deflection spectroscopy.

  14. Measurement of Wigner function via atomic beam deflection in Raman- Nath regime

    CERN Document Server

    Khosa, A H; Khosa, Ashfaq Hussain

    2002-01-01

    We propose a method for the reconstruction of photon statistics and hence the Wigner function of a quantized cavity field. The method is based on the measurement of momentum distribution of two level atoms after atom- field interaction in Raman-Nath regime. We reconstruct the photon statistics of the cavity field both the cases of resonant and off- resonant atom field interaction.. For the measurement of Wigner function we propose to displace the photon statistics of the cavity field. We successfully reconstruct the Wigner function of the Schrodinger-cat state in a straightforward manner by employing the proposed method without much mathematical manipulation of the experimental data.

  15. Deflection of proton beams by crystal miscut surface

    CERN Document Server

    Babaev, A A; Dabagov, S B

    2014-01-01

    First computer experiment results on proton beam deflection by the crystal miscut surface are presented. The phenomenology of proton channeling and quasichanneling has been applied to describe new features of the beam deflection. The analysis predicts efficient beam deflection by the acute crystal end due to repelling miscut potential.

  16. Cold beam of isotopically pure Yb atoms by deflection using 1D-optical molasses

    Science.gov (United States)

    Rathod, K. D.; Singh, P. K.; Natarajan, Vasant

    2014-09-01

    We demonstrate generation of an isotopically pure beam of laser-cooled Yb atoms by deflection using 1D-optical molasses. Atoms in a collimated thermal beam are first slowed using a Zeeman Slower. They are then subjected to a pair of molasses beams inclined at $45^\\circ$ with respect to the slowed atomic beam. The slowed atoms are deflected and probed at a distance of 160 mm. We demonstrate selective deflection of the bosonic isotope $^{174}$Yb, and the fermionic isotope $^{171}$Yb. Using a transient measurement after the molasses beams are turned on, we find a longitudinal temperature of 41 mK.

  17. Cold beam of isotopically pure Yb atoms by deflection using 1D-optical molasses

    Indian Academy of Sciences (India)

    K D Rathod; P K Singh; Vasant Natarajan

    2014-09-01

    We demonstrate the generation of an isotopically pure beam of laser-cooled Yb atoms by deflection using 1D-optical molasses. Atoms in a collimated thermal beam are first slowed using a Zeeman slower. They are then subjected to a pair of molasses beams inclined at 45° with respect to the slowed atomic beam. The slowed atoms are deflected and probed at a distance of 160 mm. We demonstrate the selective deflection of the bosonic isotope 174Yb and the fermionic isotope 171Yb. Using a transient measurement after the molasses beams are turned on, we find a longitudinal temperature of 41 mK.

  18. Directed energy deflection laboratory measurements

    Science.gov (United States)

    Brashears, Travis; Lubin, Phillip; Hughes, Gary B.; Meinhold, Peter; Suen, Jonathan; Batliner, Payton; Motta, Caio; Griswold, Janelle; Kangas, Miikka; Johansson, Isbella; Alnawakhtha, Yusuf; Prater, Kenyon; Lang, Alex; Madajian, Jonathan

    2015-09-01

    We report on laboratory studies of the effectiveness of directed energy planetary defense as a part of the DESTAR (Directed Energy System for Targeting of Asteroids and exploRation) program. DE-STAR [1][5][6] and DE-STARLITE [2][5][6] are directed energy "stand-off" and "stand-on" programs, respectively. These systems consist of a modular array of kilowatt-class lasers powered by photovoltaics, and are capable of heating a spot on the surface of an asteroid to the point of vaporization. Mass ejection, as a plume of evaporated material, creates a reactionary thrust capable of diverting the asteroid's orbit. In a series of papers, we have developed a theoretical basis and described numerical simulations for determining the thrust produced by material evaporating from the surface of an asteroid [1][2][3][4][5][6]. In the DE-STAR concept, the asteroid itself is used as the deflection "propellant". This study presents results of experiments designed to measure the thrust created by evaporation from a laser directed energy spot. We constructed a vacuum chamber to simulate space conditions, and installed a torsion balance that holds an "asteroid" sample. The sample is illuminated with a fiber array laser with flux levels up to 60 MW/m2 which allows us to simulate a mission level flux but on a small scale. We use a separate laser as well as a position sensitive centroid detector to readout the angular motion of the torsion balance and can thus determine the thrust. We compare the measured thrust to the models. Our theoretical models indicate a coupling coefficient well in excess of 100 μN/Woptical, though we assume a more conservative value of 80 μN/Woptical and then degrade this with an optical "encircled energy" efficiency of 0.75 to 60 μN/Woptical in our deflection modeling. Our measurements discussed here yield about 45 μN/Wabsorbed as a reasonable lower limit to the thrust per optical watt absorbed.

  19. Ion Beam Shepherd for Asteroid Deflection

    CERN Document Server

    Bombardelli, C

    2011-01-01

    We present a novel concept to impart a continuous thrust to an Earth threatening asteroid from a hovering spacecraft without need for physical attachment nor gravitational interaction with the asteroid. The concept involves an ion thruster placed at a distance of a few asteroid diameters directing a stream of quasi-neutral plasma against the asteroid surface resulting into a net transferred momentum. As the transmitted force is independent of the asteroid mass and size the method allows deflecting subkilometer asteroids with a spacecraft much lighter when compared to a gravity tractor spacecraft of equal deflection capability. The finding could make low-cost asteroid deflection missions possible in the coming years.

  20. New results from the CERN-SPS beam deflection experiments with bent crystals

    Science.gov (United States)

    Baurichter, A.; Kirsebom, K.; Medenwaldt, R.; Møller, S. P.; Worm, T.; Uggerhøj, E.; Mikkelsen, U.; Graftström, P.; Gatignon, L.; Elsener, K.; Doble, N.; Biino, C.; Freund, A.; Vilakazi, Z.; Hage-Ali, M.; Siffert, P.; Clément, M.

    1996-10-01

    Results from five distinct bending experiments performed recently in the H8 beam at CERN are presented. Firstly, deflection of a positive pion beam at 200 GeV/c is compared to the "standard" 450-GeV/c proton beam for a bending angle of 3.1 mrad along the (111) plane in a 50 mm silicon crystal. Second, deflection of negative pions at 200 GeV/c is investigated for the same crystal, for incidence along the (111) plane as well as the axis. Small deflection effects are seen, but no negative particles are bent through the full bending angle of the crystal. Third, the first results from beam deflection at high energy using a germanium crystal are shown. Slightly higher deflection efficiencies than for silicon are seen for large bending angles, but significantly smaller than expected for such a crystal with higher atomic number. Fourth, deflection efficiencies using a strongly irradiated silicon crystal have been measured for the first time, and a small reduction in efficiency is seen in the irradiated region. Finally, deflection of positive particles using axial alignment of a bent silicon crystal has been investigated at 450 GeV/c. Qualitatively similar behaviour as in previous experiments at 12 GeV/c is seen; the beam splits into several beams corresponding to the different planes, and even weak planes are observed.

  1. Effect of layer length on deflection in sandwich beams

    Science.gov (United States)

    Abbu, Muthanna A.; AL-Ameri, Riyadh

    2017-09-01

    A theoretical study has been carried out on sandwich beams strengthened mechanically by two external steel plates attached to their tension and compression sides with so-called "shear connectors ". This study is based on the individual behaviour of each component of the composite sandwich section (i.e. reinforced concrete beam and upper steel plate and lower steel plate). The approach has been developed to simulate the behaviour of such beams, and is based on neglecting the separation between the three layers; i.e., the deflections are equal in each element through the same section. The differential equations reached were solved analytically. Deflection was calculated by using the approach for several beams, tested in two series, and close agreements were obtained with the experimental values. Furthermore, the interaction efficiency between the three elements in a composite sandwich beam has been considered thoroughly, from which the effect of some parameters, such as plate length upon the behaviour of such beams, were studied.

  2. Ultrafast optical beam deflection in a pump probe configuration

    Science.gov (United States)

    Liang, Lingliang; Tian, Jinshou; Wang, Tao; Wu, Shengli; Li, Fuli; Wang, Junfeng; Gao, Guilong

    2016-09-01

    Propagation of a signal beam in an AlGaAs/GaAs waveguide multiple-prism light deflector is theoretically investigated by solving the scalar Helmholtz equation to obtain the dependences of the temporal and spatial resolvable characteristics of the ultrafast deflector on the material dispersion of GaAs including group velocity dispersion and angular dispersion, interface reflection, and interface scattering of multiple-prism deflector. Furthermore, we experimentally confirm that, in this ultrafast beam deflection device, the deflecting angle of the signal light beam is linear with the pump fluence and the temporal resolution of the ultrafast deflection is 10 ps. Our results show that the improvement of the temporal and spatial resolvable performances is possible by properly choosing the structural parameters and enhancing the quality of the device. Project supported by the National Natural Science Foundation of China (Grant Nos. 11274377 and 61176006) and the State Major Research Equipment Project, China (Grant No. ZDY2011-2).

  3. Large deflection analysis of cantilever beam under end point and distributed load

    DEFF Research Database (Denmark)

    Kimiaeifar, Amin; Tolou, N; Barari, Amin;

    2014-01-01

    Although the deflection of beams has been studied for decades, the solutions were either linearized (i.e. small deflection) or based on elliptic integrals or functions (large deflection). The latter one includes the geometric nonlinearity but calculation of the deflection along the beam length re...

  4. Analytical Approach to Predict Pre–Camber Deflection of the Pre-stressed Glulam Beams

    Directory of Open Access Journals (Sweden)

    Anshari B.

    2015-01-01

    Full Text Available A new approach to reinforce glulam timber beams using compressed wood (CW has been developed by the Author. The compressed wood blocks are inserted into pre-cut holes on the top of glulam beams to produce pre-camber and to generate initial tensile and compressive stresses on the top and on the bottom extreme fiber of the glulam beam, respectively. A simple analytical approach has been developed to predict pre-camber deflections of the beams reinforced with three CW blocks. Assuming that moisture-dependent expansion of the CW block creates an interactive linear pressure between the glulam beam and the CW block, this would generate a pair of eccentric force away from the neutral axis of the beam. It is shown that the pre-camber deflection predicted at midspan of the short beams with various reinforcing arrangements give good agreement with the measured pre-camber from previous experimental results.

  5. Deflection unit for multi-beam mask making

    Science.gov (United States)

    Letzkus, Florian; Butschke, Joerg; Irmscher, Mathias; Jurisch, Michael; Klingler, Wolfram; Platzgummer, Elmar; Klein, Christof; Loeschner, Hans; Springer, Reinhard

    2008-10-01

    Two main challenges of future mask making are the decreasing throughput of the pattern generators and the insufficient line edge roughness of the resist structures. The increasing design complexity with smaller feature sizes combined with additional pattern elements of the Optical Proximity Correction generates huge data volumes which reduce correspondingly the throughput of conventional single e-beam pattern generators. On the other hand the achievable line edge roughness when using sensitive chemically amplified resists does not fulfill the future requirements. The application of less sensitive resists may provide an improved roughness, however on account of throughput, as well. To overcome this challenge a proton multi-beam pattern generator is developed [1]. Starting with a highly parallel broad beam, an aperture-plate is used to generate thousands of separate spot beams. These beams pass through a blanking-plate unit, based on a CMOS device for de-multiplexing the writing data and equipped with electrodes placed around the apertures switching the beams "on" or "off", dependent on the desired pattern. The beam array is demagnified by a 200x reduction optics and the exposure of the entire substrate is done by a continuous moving stage. One major challenge is the fabrication of the required high aspect deflection electrodes and their connection to the CMOS device. One approach is to combine a post-processed CMOS chip with a MEMS component containing the deflection electrodes and to realize the electrical connection of both by vertical integration techniques. For the evaluation and assessment of this considered scheme and fabrication technique, a proof-of-concept deflection unit has been realized and tested. Our design is based on the generation of the deflection electrodes in a silicon membrane by etching trenches and oxide filling afterwards. In a 5mm x 5mm area 43,000 apertures with the corresponding electrodes have been structured and wired individually or in

  6. Experimental Estimating Deflection of a Simple Beam Bridge Model Using Grating Eddy Current Sensors

    Directory of Open Access Journals (Sweden)

    Hui Zhao

    2012-07-01

    Full Text Available A novel three-point method using a grating eddy current absolute position sensor (GECS for bridge deflection estimation is proposed in this paper. Real spatial positions of the measuring points along the span axis are directly used as relative reference points of each other rather than using any other auxiliary static reference points for measuring devices in a conventional method. Every three adjacent measuring points are defined as a measuring unit and a straight connecting bar with a GECS fixed on the center section of it links the two endpoints. In each measuring unit, the displacement of the mid-measuring point relative to the connecting bar measured by the GECS is defined as the relative deflection. Absolute deflections of each measuring point can be calculated from the relative deflections of all the measuring units directly without any correcting approaches. Principles of the three-point method and displacement measurement of the GECS are introduced in detail. Both static and dynamic experiments have been carried out on a simple beam bridge model, which demonstrate that the three-point deflection estimation method using the GECS is effective and offers a reliable way for bridge deflection estimation, especially for long-term monitoring.

  7. Theory of using magnetic deflections to combine charged particle beams

    Energy Technology Data Exchange (ETDEWEB)

    Steckbeck, Mackenzie K. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Doyle, Barney Lee [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-09-01

    Several radiation effects projects in the Ion Beam Lab (IBL) have recently required two disparate charged particle beams to simultaneously strike a single sample through a single port of the target chamber. Because these beams have vastly different mass–energy products (MEP), the low-MEP beam requires a large angle of deflection toward the sample by a bending electromagnet. A second electromagnet located further upstream provides a means to compensate for the small angle deflection experienced by the high-MEP beam during its path through the bending magnet. This paper derives the equations used to select the magnetic fields required by these two magnets to achieve uniting both beams at the target sample. A simple result was obtained when the separation of the two magnets was equivalent to the distance from the bending magnet to the sample, and the equation is given by: Bs= 1/2(rc/rs) Bc, where Bs and Bc are the magnetic fields in the steering and bending magnet and rc/rs is the ratio of the radii of the bending magnet to that of the steering magnet. This result is not dependent upon the parameters of the high MEP beam, i.e. energy, mass, charge state. Therefore, once the field of the bending magnet is set for the low-MEP beam, and the field in the steering magnet is set as indicted in the equation, the trajectory path of any high-MEP beam will be directed into the sample.

  8. Quasi first-order Hermite Gaussian beam for enhanced sensitivity in Sagnac interferometer photothermal deflection spectroscopy.

    Science.gov (United States)

    Shiokawa, Naoyuki; Tokunaga, Eiji

    2016-05-30

    The detection sensitivity of a Sagnac interferometer photothermal deflection spectroscopy was enhanced by changing the probe beam pattern from zero-order to a quasi-first-order Hermite Gaussian (QHG) beam. The nature of the higher order HG mode, where the beam pattern is preserved during propagation with an increased field gradient, is utilized to enhance the measurement sensitivity. In this spectroscopy, the lateral beam deflection due to the photothermal effect is sensitively detected as a change in the interference light intensity. The change in intensity is amplified due to the higher field gradient of the QHG(1,0) beam at the photodetector. This amplification effect was both numerically and experimentally demonstrated to obtain twofold improvement in the signal-to-noise ratio.

  9. Large deflection of flexible tapered functionally graded beam

    Institute of Scientific and Technical Information of China (English)

    A.R.Davoodinik; G.H.Rahimi

    2011-01-01

    In this paper the semi-analytical analyses of the flexible cantilever tapered functionally graded beam under combined inclined end loading and intermediate loading are studied.In order to derive the fully non-linear equations governing the non-linear deformation,a curvilinear coordinate system is introduced.A general non-linear second order differential equation that governs the shape of a deflected beam is derived based on the geometric nonlinearities,infinitesimal local displacements and local rotation concepts with remarkable physical properties of functionally graded materials.The solutions obtained from semi-analytical methods are numerically compared with the existing elliptic integral solution for the case of a flexible uniform cantilever functionally graded beam.The effects of taper ratio,inclined end load angle and material property gradient on large deflection of the beam are evaluated.The Adomian decomposition method will be useful toward the design of tapered functionally graded compliant mechanisms driven by smart actuators.

  10. Electrostatic deflection of a molecular beam of massive neutral particles: Fully field-oriented polar molecules within superfluid nanodroplets

    CERN Document Server

    Merthe, Daniel J

    2016-01-01

    Electric deflection measurements on liquid helium nanodroplets doped with individual polar molecules demonstrate that the cold superfluid matrix enables full orientation of the molecular dipole along the external field. This translates into a deflection force which is increased enormously by comparison with typical deflection experiments, and it becomes possible to measurably deflect neutral doped droplets with masses of tens to hundreds of thousands of Daltons. This approach permits preparation and study of continuous fluxes of fully oriented polar molecules and is broadly and generally applicable, including to complex and biological molecules. It is shown that the dipole moments of internally cryogenically cold molecules can be directly determined from a deflection measurement on the doped nanodroplet beam.

  11. Application of artificial neural networks to predict the deflections of reinforced concrete beams

    Science.gov (United States)

    Kaczmarek, Mateusz; Szymańska, Agnieszka

    2016-06-01

    Nonlinear structural mechanics should be taken into account in the practical design of reinforced concrete structures. Cracking is one of the major sources of nonlinearity. Description of deflection of reinforced concrete elements is a computational problem, mainly because of the difficulties in modelling the nonlinear stress-strain relationship of concrete and steel. In design practise, in accordance with technical rules (e.g., Eurocode 2), a simplified approach for reinforced concrete is used, but the results of simplified calculations differ from the results of experimental studies. Artificial neural network is a versatile modelling tool capable of making predictions of values that are difficult to obtain in numerical analysis. This paper describes the creation and operation of a neural network for making predictions of deflections of reinforced concrete beams at different load levels. In order to obtain a database of results, that is necessary for training and testing the neural network, a research on measurement of deflections in reinforced concrete beams was conducted by the authors in the Certified Research Laboratory of the Building Engineering Institute at Wrocław University of Science and Technology. The use of artificial neural networks is an innovation and an alternative to traditional methods of solving the problem of calculating the deflections of reinforced concrete elements. The results show the effectiveness of using artificial neural network for predicting the deflection of reinforced concrete beams, compared with the results of calculations conducted in accordance with Eurocode 2. The neural network model presented in this paper can acquire new data and be used for further analysis, with availability of more research results.

  12. Characterization of acoustic effects on flame structures by beam deflection technique

    Energy Technology Data Exchange (ETDEWEB)

    Bedat, B.; Kostiuk, L.W.; Cheng, R.K.

    1993-10-01

    This work shows that the acoustic effects are the causes of the small amplitude flame wrinkling and movements seen in all the different gravitational conditions. The comparison between the acoustic velocity and beam deflection spectra for the two conditions studied (glass beads and fiber glass) demonstrates clearly this flame/acoustic coupling. This acoustic study shows that the burner behaves like a Helmholtz resonator. The estimated resonance frequency corresponds well to the experimental measurements. The fiber glass damps the level of the resonance frequency and the flame motion. The changes shown in normalized beam deflection spectra give further support of this damping. This work demonstrates that the acoustics has a direct influence on flame structure in the laminar case and the preliminary results in turbulent case also show a strong coupling. The nature of this flame/acoustic coupling are still not well understood. Further investigation should include determining the frequency limits and the sensitivity of the flame to acoustic perturbations.

  13. Evaluation of disparate laser beam deflection technologies by means of number and rate of resolvable spots.

    Science.gov (United States)

    Bechtold, Peter; Hohenstein, Ralph; Schmidt, Michael

    2013-08-15

    We introduce a method to objectively evaluate systems of differing beam deflection technologies that commonly are described by disparate technical specifications. Using our new approach based on resolvable spots we will compare commercially available random-access beam deflection technologies, namely galvanometer scanners, piezo scanners, MEMS scanners, acousto-optic deflectors, and electro-optic deflectors.

  14. Improvements of the undulator spectral performance by compensating the backing beam deflection

    CERN Document Server

    Wang, C; Chang, L H; Chang, C H; Fan, T C; Bach, H; Blomqvist, I

    2002-01-01

    This study thoroughly examines how the backing beam deflection affects the undulator spectral performance. Reduction of the undulator spectral intensity owing to backing beam deflection is analytically evaluated based on plane-wave approximation. The results reveal that the amplitude and the slope of the backing beam deflection affect the undulator spectral performance. Provided is a novel figure-of-merit, rms of the regressed accumulated gap deviation, to determine the backing beam deflection budget. An example of a 3.9 m undulator supporting carriage mounted with 50-mm period length undulator magnet (U5) under a maximum magnetic loading of 5 metric tons at a minimum operating gap of 14 mm, is provided. Its mechanical features are first examined via 3D commercial finite element code ANSYS that concludes the backing beam deflection is influenced heavily by the rigidity of the undulator support frames. Examining the corresponding spectral performance shows that significantly diminishing the undulator spectral ...

  15. Maximum Stress Estimation Model for Multi-Span Waler Beams with Deflections at the Supports Using Average Strains

    Directory of Open Access Journals (Sweden)

    Sung Woo Park

    2015-03-01

    Full Text Available The safety of a multi-span waler beam subjected simultaneously to a distributed load and deflections at its supports can be secured by limiting the maximum stress of the beam to a specific value to prevent the beam from reaching a limit state for failure or collapse. Despite the fact that the vast majority of accidents on construction sites occur at waler beams in retaining wall systems, no safety monitoring model that can consider deflections at the supports of the beam is available. In this paper, a maximum stress estimation model for a waler beam based on average strains measured from vibrating wire strain gauges (VWSGs, the most frequently used sensors in construction field, is presented. The model is derived by defining the relationship between the maximum stress and the average strains measured from VWSGs. In addition to the maximum stress, support reactions, deflections at supports, and the magnitudes of distributed loads for the beam structure can be identified by the estimation model using the average strains. Using simulation tests on two multi-span beams, the performance of the model is evaluated by estimating maximum stress, deflections at supports, support reactions, and the magnitudes of distributed loads.

  16. Comparative Studies on Effects of Acid Solutions on Aquatic Plants by Beam Deflection and Absorbance Spectroscopy Methods.

    Science.gov (United States)

    Wu, Xing-Zheng; Nie, Liangjiao; Inoue, Tomomi

    2015-01-01

    The beam deflection method and absorbance spectroscopy were applied to study effects of acid solutions on aquatic plants, and their results were compared. Aquatic plants Egeria densa and Ceratophyllum demersum L were used as model plants. In absorbance experiments, a piece of the plants was put in a beaker with 20 mL HCl solution, and absorbance of the HCl solution was measured every 30 min. In beam deflection experiments, a probe beam from a He-Ne laser was focused to a vicinity of the plants in a culture dish with HCl solution by an objective lens, and deflection signals of the probe beam were monitored by a position sensor. Absorbance spectra of the HCl solutions with immersing of the plants showed absorbance below 410 nm, suggesting that some compounds leaked from the plants into the HCl solutions. Changes of absorbance and deflection signals with immersion time were examined for different pH levels. The changing trends of the absorbance and deflection signals with time were similar, but the absorbance changes were delayed for about 2 - 3 h. The absorbance method could not detect the effect of the pH 5.0 HCl solutions on the aquatic plants, while the deflection method could.

  17. First Observation of the Deflection of a 33 TeV Pb Ion Beam in a Bent Silicon Crystal

    Science.gov (United States)

    Elsener, K.; Biino, C.; Clement, M.; Doble, N.; Gatignon, L.; Grafstrom, P.; Mikkelsen, U.; Taratin, A.; Møller, S. P.; Uggerhøj, E.

    1997-05-01

    The deflection of an ultra-relativistic, fully stripped Pb(82+) ion beam in a bent silicon crystal has been observed for the first time. The ions were provided by the CERN-SPS in the H4 beam at a momentum of 400 GeV/c/Z. A 60 mm long silicon crystal, bent over 50 mm to give a 4 mrad deflection angle, was used in this experiment. The measured Pb ion deflection efficiencies are comparable to the ones obtained with protons at an equivalent ratio p/Z, and are found to be about 15% for a beam with a divergence of 50 microradians (FWHM). The interaction rate observed in a background counter is reduced by about the same 15% when the crystal is well aligned with the beam. This corroborates further the channeling model, which predicts that channeled ions are steered away from regions of high electron densities as well as from the nuclei in the crystal.

  18. All-optical optoacoustic microscopy system based on probe beam deflection technique

    Science.gov (United States)

    Maswadi, Saher M.; Tsyboulskic, Dmitri; Roth, Caleb C.; Glickman, Randolph D.; Beier, Hope T.; Oraevsky, Alexander A.; Ibey, Bennett L.

    2016-03-01

    It is difficult to achieve sub-micron resolution in backward mode OA microscopy using conventional piezoelectric detectors, because of wavefront distortions caused by components placed in the optical path, between the sample and the objective lens, that are required to separate the acoustic wave from the optical beam. As an alternate approach, an optoacoustic microscope (OAM) was constructed using the probe beam deflection technique (PBDT) to detect laserinduced acoustic signals. The all-optical OAM detects laser-generated pressure waves using a probe beam passing through a coupling medium, such as water, filling the space between the microscope objective lens and sample. The acoustic waves generated in the sample propagate through the coupling medium, causing transient changes in the refractive index that deflect the probe beam. These deflections are measured with a high-speed, balanced photodiode position detector. The deflection amplitude is directly proportional to the magnitude of the acoustic pressure wave, and provides the data required for image reconstruction. The sensitivity of the PBDT detector expressed as noise equivalent pressure was 12 Pa, comparable to that of existing high-performance ultrasound detectors. Because of the unimpeded working distance, a high numerical aperture objective lens, i.e. NA = 1, was employed in the OAM to achieve near diffraction-limited lateral resolution of 0.5 μm at 532nm. The all-optical OAM provides several benefits over current piezoelectric detector-based systems, such as increased lateral and axial resolution, higher sensitivity, robustness, and potentially more compatibility with multimodal instruments.

  19. A nonlinear mathematical model for large deflection of incompressible saturated poroelastic beams

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Nonlinear governing equations are established for large deflection of incompressible fluid saturated poroelastic beams under constraint that diffusion of the pore fluid is only in the axial direction of the deformed beams. Then, the nonlinear bending of a saturated poroelastic cantilever beam with fixed end impermeable and free end permeable, subjected to a suddenly applied constant concentrated transverse load at its free end, is examined with the Galerkin truncation method. The curves of deflections and bending moments of the beam skeleton and the equivalent couples of the pore fluid pressure are shown in figures. The results of the large deflection and the small deflection theories of the cantilever poroelastic beam are compared, and the differences between them are revealed. It is shown that the results of the large deflection theory are less than those of the corresponding small deflection theory, and the times needed to approach its stationary states for the large deflection theory are much less than those of the small deflection theory.

  20. Large deflection angle, high-power adaptive fiber optics collimator with preserved near-diffraction-limited beam quality.

    Science.gov (United States)

    Zhi, Dong; Ma, Yanxing; Chen, Zilun; Wang, Xiaolin; Zhou, Pu; Si, Lei

    2016-05-15

    We report on the development of a monolithic adaptive fiber optics collimator, with a large deflection angle and preserved near-diffraction-limited beam quality, that has been tested at a maximal output power at the 300 W level. Additionally, a new measurement method of beam quality (M2 factor) is developed. Experimental results show that the deflection angle of the collimated beam is in the range of 0-0.27 mrad in the X direction and 0-0.19 mrad in the Y direction. The effective working frequency of the device is about 710 Hz. By employing the new measurement method of the M2 factor, we calculate that the beam quality is Mx2=1.35 and My2=1.24, which is in agreement with the result from the beam propagation analyzer and is preserved well with the increasing output power.

  1. Deflection measurements of LABAN canister sections in horizontal attitude

    Energy Technology Data Exchange (ETDEWEB)

    Wakeman, W.

    1985-01-08

    Deflection measurements made on the LABAN canister sections indicate that the apparent stiffness of its frames, with all the diagnostics experiments installed, is not significantly different from the stiffness of the bare frames.

  2. Large deflection and rotation of Timoshenko beams with frictional end supports under three-point bending

    Science.gov (United States)

    Li, Dao-Kui; Li, Xian-Fang

    2016-08-01

    Three-point bending of a beam is studied based on the Timoshenko beam theory. Large deflection and large rotation of a beam resting on simple supports with friction are calculated for a concentrated force acting at the midspan. Using the Lagrangian kinematic relations, a system of non-linear differential equations are obtained for a prismatic shear-deformable Timoshenko beam. Exact solutions for the deflection, horizontal displacement, and rotation of cross-section are derived analytically. Two deflections of small and large scale exist under three-point bending. The solutions corresponding to linearized model coincide with the well-known solutions to the classical Timoshenko beams. Numerical calculations are carried out to show the effect of the important parameters such as shear rigidity of the beam and the coefficient of friction at the contact position between the beam and supports on the deflection. The load-deflection curves are graphically presented. A comparison of large deflections and large rotations with their classical counterparts and with experimental data is made. The obtained results are useful in safety design of linear and non-linear beams subject to three-point bending.

  3. Laser heating of a cavity versus a plane surface for metal targets utilizing photothermal deflection measurements

    Science.gov (United States)

    Jeong, S. H.; Greif, R.; Russo, R. E.

    1996-08-01

    The effects of a cylindrical cavity in a metal surface on the energy coupling of a laser beam with the solid were investigated by using a photothermal deflection technique. The photothermal deflection of a probe beam over the cavity was measured while the bottom of the cavity was heated with a Nd-YAG laser with a wavelength of 1064 nm. Cavities in three different materials and with two different aspect ratios were used for the experiment. Temperature distributions in the solid and the surrounding air were computed numerically and used to calculate photothermal deflections for cavity heating and for plane surface heating. Reflection of the heating laser beam inside the cavity increased the photothermal deflection amplitude significantly with larger increases for materials with larger thermal diffusivity. The computed photothermal deflections agreed more closely with the experimental results when reflection of the heating laser beam inside the cavity was included in the numerical model. The overall energy coupling between a heating laser and a solid is enhanced by a cavity.

  4. An improved small-deflection electromechanical model for piezoelectric bending beam actuators and energy harvesters

    Science.gov (United States)

    Tabesh, Ahmadreza; Fréchette, Luc G.

    2008-10-01

    The analytical model presented in this paper describes the energy conversion mechanism of a piezoelectric beam (bimorph) under small-deflection static and vibrating conditions. The model provides an improved approach to design and analyze the performance of piezoelectric actuators and energy harvesters (sensors). Conventional models assume a linear voltage distribution over the piezoelectric beam thickness, which is shown here to be invalid. The proposed modeling method improves accuracy by using a quadratic voltage distribution. The equivalent capacitance of a beam shows a 40% discrepancy between a conventional model and the proposed model for PZT5A material. This inaccuracy level is not negligible, especially when the design of micro-power electrical energy harvesting is concerned. The method solves simultaneously the solid mechanics and Maxwell's equations with the constitutive equations for piezoelectric materials. The paper also proposes a phasor-based procedure for measuring the damping of a piezoelectric beam. An experimental setup is developed to verify the validity of the model. The experimental results confirm the accuracy of the improved model and also reveal limitations in using models for small deflections.

  5. Laser-driven deflection arrangements and methods involving charged particle beams

    Science.gov (United States)

    Plettner, Tomas [San Ramon, CA; Byer, Robert L [Stanford, CA

    2011-08-09

    Systems, methods, devices and apparatus are implemented for producing controllable charged particle beams. In one implementation, an apparatus provides a deflection force to a charged particle beam. A source produces an electromagnetic wave. A structure, that is substantially transparent to the electromagnetic wave, includes a physical structure having a repeating pattern with a period L and a tilted angle .alpha., relative to a direction of travel of the charged particle beam, the pattern affects the force of the electromagnetic wave upon the charged particle beam. A direction device introduces the electromagnetic wave to the structure to provide a phase-synchronous deflection force to the charged particle beam.

  6. Mission Analysis For the Ion Beam Deflection of Fictitious Asteroid 2015PDC

    CERN Document Server

    Bombardelli, Claudio; Cano, Juan Luis

    2015-01-01

    A realistic mission scenario for the deflection of fictitious asteroid 2015PDC is investigated that makes use of the ion beam shepherd concept as primary deflection technique. The article deals with the design of a low thrust rendezvous trajectory to the asteroid, the estimation of the propagated covariance ellipsoid and the outcome of a slow-push deflection starting from three worst case scenarios (impacts in New Delhi, Dhaka and Teheran). Displacing the impact point towards very low populated areas, as opposed to full deflection, is found to be the simplest and most effective mitigation approach. Mission design, technical and political aspects are discussed.

  7. Photonic-based laser driven electron beam deflection and focusing structures

    Directory of Open Access Journals (Sweden)

    T. Plettner

    2009-10-01

    Full Text Available We propose a dielectric photonic structure for ultrafast deflection and focusing of relativistic charged particle beams. The structure is designed to transform a free-space laser beam into a deflection force that acts on the free particles with the same optical phase over a distance of travel that is much greater than the laser wavelength. The proposed structure has a two-dimensional geometry and is compatible with existing nanofabrication methods. Deflection fields of GV/m magnitude and subfemtosecond switching speeds are expected to be possible from these dielectric structures. With these elements a submeter scale extreme ultraviolet synchrotron source seems feasible.

  8. The 1919 measurement of the deflection of light

    CERN Document Server

    Will, Clifford M

    2014-01-01

    The measurement of the deflection of starlight during a total solar eclipse on May 29, 1919 was the first verification of general relativity by an external team of scientists, brought Einstein and his theory to the attention of the general public, and left a legacy of experimental testing that continues today. The discovery of gravitational lenses turned Einstein's deflection into an important tool for astronomy and cosmology. This article reviews the history of the 1919 measurement and other eclipse measurements, describes modern measurements of the effect using radio astronomy, and of its cousin, the Shapiro time delay, and discusses gravitational lenses.

  9. Record Deflection Efficiencies Measured for High Energy Protons in a Bent Germanium Crystal

    Science.gov (United States)

    Elsener, K.; Biino, C.; Clement, M.; Doble, N.; Gatignon, L.; Grafstrom, P.; Mikkelsen, U.; Kirsebom, K.; Møller, S. P.; Uggerhøj, E.; Worm, T.; Freund, A.

    1997-05-01

    New experimental results on the deflection of 450 GeV/c and 200 GeV/c protons in a bent Ge crystal are presented. At 450 GeV/c, the 50 mm long crystal gave record deflection efficiencies up to 60% for small angles (1 mrad), while at angles as large as 12 mrad, the efficiency is about 25 times larger than for a silicon crystal of the same size. Measurements up to 20 mrad deflection angle have been performed at 200 GeV/c as well as 450 GeV/c - the lower bending dechanneling leads to a rather slow decrease in efficiency at lower momenta, and 15% of the 200 GeV/c beam hitting the crystal are still deflected at the largest angles measured. These experimental results are in good agreement with a model for channeling deflection developed by Ellison and give confidence in extrapolations to higher energies (e.g. to LHC), other crystal materials or different deflection angles.

  10. Pulsed-laser Pumped Photothermal Deflection Spectroscopy for Liquid Thermal Diffusivity Measurement

    Institute of Scientific and Technical Information of China (English)

    XIAO Liantuan; LI Changyong; ZHANG Linjie; ZHAO Yanting; JIA Suotang; ZHOU Guosheng

    2000-01-01

    The pulsed-laser pumped photothermal deflection spectroscopy (PPDS) is applied to measure liquid thermal diffusivity in a modified collinear configuration. Here the pulsed beam is regarded as in the form of a Dirac delta function. The experiment setup used is described. Measurement result for the thermal diffusivity of a liquid sample(magnta/ethanol saturated solution) is reported. The measurement error is less than 3%.

  11. Invariant electro-optical system for deflection measurement of floating docks

    Science.gov (United States)

    Gorbachev, Alexey A.; Hoang, Anh Phuong

    2017-06-01

    An electro-optical system for deflection measurement of floating docks is represented in this paper. This system contains a base unit with two measurement channels observing opposite directions of the dock. It also includes a set of reference marks and an industrial computer. The measurement unit contains of a camera with long focal-length lens and a beam splitter. The effect of the beam splitter turning point on the image position of the reference mark on the camera is analyzed as well in this paper.

  12. Measurement of Large Forces and Deflections in Microstructures

    CERN Document Server

    Hals, Kai Axel; Chen, Xuyuan

    2008-01-01

    Properties of typical MEMS materials have been widely investigated. Mechanical properties of MEMS structures depend not only on the bulk material properties, but also structural factors. A measurement system has been made to measure force/deflection on microstructures to examine some of the structural properties. This is a stylus setup integrated with a load cell and a linear actuator. First, the requirements for the measurement system were established. Then the system was built up and characterized. We have successfully made measurements on a typical micromechanical structure, a cantilever accelerometer design. The stylus placement accuracy, the spring constant along the proof mass, analysis of the force/deflection curve shape and destructive tests on the cantilever have been investigated in our experiment and will be presented in this paper.

  13. Beam deflection induced by E×B near a linear filament cathode

    Science.gov (United States)

    Zhang, Huashun; Jiang, Jiasheng

    2017-02-01

    Beam deflection induced by E×B near a linear filament cathode in a two grid electron gun is presented theoretically and experimentally. The experimental results are consistent with the calculation based on the theoretical equations. The influences upon performance and design of electron gun with linear filament cathode, which is used broadly in electrocurtain accelerators, are discussed in detail.

  14. A geometrically non-linear formulation of a three-dimensional beam element for solving large deflection multibody system problems

    NARCIS (Netherlands)

    Jonker, J.B.; Meijaard, J.P.

    2013-01-01

    A beam finite element formulation for large deflection problems in the analysis of flexible multibody systems has been proposed. In this formulation, a set of independent discrete deformation modes are defined for each element which are related to conventional small deflection beam theory in a co-ro

  15. Estimation of the deflection of the vertical using gravity measurements

    Science.gov (United States)

    Manoussakis, Gerassimos; Korakitis, Romylos; Milas, Paraskevas

    2017-04-01

    We present a method to estimate the deflection of the vertical at a point P on the Earth's physical surface by forming a small network of three points around point P, with known geodetic coordinates (φ, λ, h) and by obtaining gravity measurements at all points. In the first step, the gravity values are used to form the Eötvös matrix of the actual gravity potential W at point P. In the second step, the gravity differences and the components of the Eötvös matrix are used to form a linear system of three algebraic equations with three unknowns, which are the first order partial derivatives of the actual potential W. The solution of the system enables us to determine the components ξ and η of the deflection of the vertical at the chosen point P. Finally, we present a numerical simulation, using several points scattered on a wide area of the Earth's surface.

  16. System for deflection measurements of floating dry docks

    Science.gov (United States)

    Gorbachev, Alexey A.; Pantyushin, Anton V.; Serikova, Mariya G.; Korotaev, Valery V.; Timofeev, Aleksandr N.

    2015-05-01

    In this paper we introduce a system for deflection measurement of floating dry docks. The system contains two measurement channels observing opposite directions of the dock. It also includes set of reference marks, an industrial computer and a display. Each channel contains CMOS camera with long focal-length lens. Reference marks are implemented as IR LED arrays with 940 nm working wavelength for better performance within bad weather conditions (e.g. fog, rain, high humidity etc.). In the paper we demonstrate results of an analysis of different optical schemes for coupling the oppositely directed channels of the measurement unit and show that the scheme with two image sensors with separated lenses is an optimal option, because it allows usage of nonequidistant location of reference marks and demonstrates the least value of parasitic shift caused by rotations of the measuring unit. The developed system was tested both on specially-designed setup and in real infrastructure of a floating dry dock. The conducted tests proved that a measuring error of the system is smaller than +/- 1.5 mm within the measurement range of +/- 150 mm when deflection of 100 m dock is measured. Obtained results showed that the system demonstrates an ability to work in a harsh environment including poor weather conditions.

  17. Assessment of the beam path deflection for a vertically installed microwave interferometer in SUNIST

    Science.gov (United States)

    Zhong, H.; Ling, B. L.; Tan, Y.; Gao, Z.

    2016-08-01

    Microwave interferometry has been widely employed to provide reliable line averaged electron density measurement on plasma devices. For a vertically installed interferometer on a tokamak, the refraction problem, which distorts the beam path and aggravates power loss at the receiving antenna, may become significant if taking the cross section shape into account. Increasing the frequency of the probing microwave can alleviate the distortion, but at the expense of losing the density resolution. To seek for an optimized frequency, previous calculations are mainly based on the cylindrical column geometry which grossly underestimates the deflection of the beam path induced by the plasma shape, and empirical suggestions indicating ne0/nc = 1/2 ˜ 1/3 may not always be the appropriate option. Here a single ray tracing method is applied to estimate the final horizontal deviation at the receiving antenna, which is supposed to represent the level of power loss. The calculation is carried out under the real tokamak geometry in Sino-UNIted Spherical Tokamak (SUNIST) with the cross section parameters obtained from the equilibrium reconstruction, and the result indicates that for a target density of 1.2 × 1019 m-3, a frequency of at least 100 GHz is desirable to reduce the power loss to an acceptable level. This would be helpful for the design of a vertically installed interferometer on SUNIST.

  18. The effects of transverse plasma flow on laser beam deflection and of ultra-intense laser beam filamentation on channel formation

    Science.gov (United States)

    Hinkel, D. E.

    1997-11-01

    Recent experiments conducted at Lawrence Livermore National Laboratory (LLNL) with the Nova and Janus lasers demonstrate deflection of the laser beam in plasma with flow transverse to the beam. In gas-filled hohlraum experiments(S. G. Glendinning et al.), the laser spot on the hohlraum wall is ~ 100 μm closer to the laser entrance hole (LEH) than in empty hohlraum experiments, which degrades drive symmetry. In a series of exploding foil experiments(J. D. Moody et al.), Phys. Rev. Lett. 77, 1294 (1996)., intensity dependent deflection of the transmitted beam is observed, and interferometric measurements of laser-produced channels in preformed plasma(P. E. Young et al.), to be submitted to Phys. Rev. Lett., 1997. show beam deflection in the presence of near-sonic transverse flow. Theoretical analysis(D. E. Hinkel et al.), Phys. Rev. Lett. 77, 1298 (1996). yields simple scaling laws for the formation of ponderomotively (or thermally) created density depressions downstream from the laser beam's high intensity regions, into which the light is refracted. An integrated approach that utilizes plasma parameters from the hydrocode Lasnex, detailed knowledge of the beam structure, and plasma physics analysis and modelling with F3D(R. L. Berger et al.), Phys. Fluids B 5, 2243 (1993)., has been used to develop a predictive capability that successfully quantifies the amount of beam deflection occurring in experiments. Related physics of beam self-focussing and filamentation is of relevance to the Fast Ignitor(M. Tabak et al.), Phys. Plasmas 1, 1626 (1994).. In channeling experiments performed on the 100 TW laser at LLNL, the f/3 laser beam, which has a 15 μm waist at best focus, has intensities in excess of IL = 1 × 10^17 W/cm^2. Modelling of these high intensity experiments indicates that channel formation occurs over a wide range of cone angles for an idealized (Gaussian) beam. However, when beam structure is taken into consideration, channel formation in the underdense

  19. Direct measurement of Vorticella contraction force by micropipette deflection.

    Science.gov (United States)

    France, Danielle; Tejada, Jonathan; Matsudaira, Paul

    2017-02-01

    The ciliated protozoan Vorticella convallaria is noted for its exceptionally fast adenosine triphosphate-independent cellular contraction, but direct measurements of contractile force have proven difficult given the length scale, speed, and forces involved. We used high-speed video microscopy to image live Vorticella stalled in midcontraction by deflection of an attached micropipette. Stall forces correlate with both distance contracted and the resting stalk length. Estimated isometric forces range from 95 to 177 nanonewtons (nN), or 1.12 nN·μm(-1) of the stalk. Maximum velocity and work are also proportional to distance contracted. These parameters constrain proposed biochemical/physical models of the contractile mechanism.

  20. Dielectric properties of isolated clusters beam deflection studies

    CERN Document Server

    Heiles, Sven

    2013-01-01

    A broad range of state-of-the-art methods to determine properties of clusters are presented. The experimental setup and underlying physical concepts of these experiments are described. Furthermore, existing theoretical models to explain the experimental observations are introduced and the possibility to deduce structural information from measurements of dielectric properties is discussed. Additional case studies are presented in the book to emphasize the possibilities but also drawbacks of the methods.

  1. A Modified Model for Deflection Calculation of Reinforced Concrete Beam with Deformed GFRP Rebar

    Directory of Open Access Journals (Sweden)

    Minkwan Ju

    2016-01-01

    Full Text Available The authors carried out experimental and analytical research to evaluate the flexural capacity and the moment-deflection relationship of concrete beams reinforced with GFRP bars. The proposed model to predict the effective moment of inertia for R/C beam with GFRP bars was developed empirically, based on Branson’s equation to have better accuracy and a familiar approach to a structural engineer. For better prediction of the moment-deflection relationship until the ultimate strength is reached, a nonlinear parameter (k was also considered. This parameter was introduced to reduce the effect of the cracked moment of inertia for the reinforced concrete member, including a lower reinforcement ratio and modulus of elasticity of the GFRP bar. In a comparative study using six equations suggested by others, the proposed model showed better agreement with the experimental test results. It was confirmed that the empirical modification based on Branson’s equation was valid for predicting the effective moment of inertia of R/C beams with GFRP bar in this study. To evaluate the generality of the proposed model, a comparative study using previous test results from the literature and the results from this study was carried out. It was found that the proposed model had better accuracy and was a familiar approach to structural engineers to predict and evaluate the deflection behavior.

  2. Proton beam deflection in MRI fields: Implications for MRI-guided proton therapy.

    Science.gov (United States)

    Oborn, B M; Dowdell, S; Metcalfe, P E; Crozier, S; Mohan, R; Keall, P J

    2015-05-01

    This paper investigates, via magnetic modeling and Monte Carlo simulation, the ability to deliver proton beams to the treatment zone inside a split-bore MRI-guided proton therapy system. Field maps from a split-bore 1 T MRI-Linac system are used as input to geant4 Monte Carlo simulations which model the trajectory of proton beams during their paths to the isocenter of the treatment area. Both inline (along the MRI bore) and perpendicular (through the split-bore gap) orientations are simulated. Monoenergetic parallel and diverging beams of energy 90, 195, and 300 MeV starting from 1.5 and 5 m above isocenter are modeled. A phase space file detailing a 2D calibration pattern is used to set the particle starting positions, and their spatial location as they cross isocenter is recorded. No beam scattering, collimation, or modulation of the proton beams is modeled. In the inline orientation, the radial symmetry of the solenoidal style fringe field acts to rotate the protons around the beam's central axis. For protons starting at 1.5 m from isocenter, this rotation is 19° (90 MeV) and 9.8° (300 MeV). A minor focusing toward the beam's central axis is also seen, but only significant, i.e., 2 mm shift at 150 mm off-axis, for 90 MeV protons. For the perpendicular orientation, the main MRI field and near fringe field act as the strongest to deflect the protons in a consistent direction. When starting from 1.5 m above isocenter shifts of 135 mm (90 MeV) and 65 mm (300 MeV) were observed. Further to this, off-axis protons are slightly deflected toward or away from the central axis in the direction perpendicular to the main deflection direction. This leads to a distortion of the phase space pattern, not just a shift. This distortion increases from zero at the central axis to 10 mm (90 MeV) and 5 mm (300 MeV) for a proton 150 mm off-axis. In both orientations, there is a small but subtle difference in the deflection and distortion pattern between protons fired parallel to the

  3. Self-contained instrument for measuring subterranean tunnel wall deflection

    Science.gov (United States)

    Rasmussen, Donald Edgar; Hof, Jr., Peter John

    1978-01-01

    The deflection of a subterranean tunnel is measured with a rod-like, self-contained instrument that is adapted to be inserted into a radially extending bore of the tunnel adjacent an end of the tunnel where the tunnel is being dug. One end of the instrument is anchored at the end of the bore remote from the tunnel wall, while the other end of the intrument is anchored adjacent the end of the wall in proximity to the tunnel wall. The two ends of the instrument are linearly displaceable relative to each other; the displacement is measured by a transducer means mounted on the instrument. Included in the instrument is a data storage means including a paper tape recorder periodically responsive to a parallel binary signal indicative of the measured displacement.

  4. Maximum Stress Estimation Model for Multi-Span Waler Beams with Deflections at the Supports Using Average Strains

    OpenAIRE

    Sung Woo Park; Byung Kwan Oh; Hyo Seon Park

    2015-01-01

    The safety of a multi-span waler beam subjected simultaneously to a distributed load and deflections at its supports can be secured by limiting the maximum stress of the beam to a specific value to prevent the beam from reaching a limit state for failure or collapse. Despite the fact that the vast majority of accidents on construction sites occur at waler beams in retaining wall systems, no safety monitoring model that can consider deflections at the supports of the beam is available. In this...

  5. Deflection monitoring for a box girder based on a modified conjugate beam method

    Science.gov (United States)

    Chen, Shi-Zhi; Wu, Gang; Xing, Tuo

    2017-08-01

    After several years of operation, a box girder bridge would commonly experience excessive deflection, which endangers the bridge’s life span as well as the safety of vehicles travelling on it. In order to avoid potential risks, it is essential to constantly monitor the defection of box girders. However, currently, the direct deflection monitoring methods are limited by the complicated environments beneath the bridges, such as rivers or other traffic lanes, which severely impede the layouts of the sensors. The other indirect deflection monitoring methods mostly do not thoroughly consider the inherent shear lag effect and shear deformation in the box girder, resulting in a rather large error. Under these circumstances, a deflection monitoring method suiting box girders is proposed in this article, based on the conjugate beam method and distributed long-gauge fibre Bragg grating (FBG) sensor. A lab experiment was conducted to verify the reliability and feasibility of this method under practical application. Further, the serviceability under different span-depth ratios and web thicknesses was examined through a finite element model.

  6. Static deflection control of flexible beams by piezo-electric actuators

    Science.gov (United States)

    Baz, A. M.

    1986-01-01

    This study deals with the utilization of piezo-electric actuators in controlling the static deformation of flexible beams. An optimum design procedure is presented to enable the selection of the optimal location, thickness and excitation voltage of the piezo-electric actuators in a way that would minimize the deflection of the beam to which these actuators are bonded. Numerical examples are presented to illustrate the application of the developed optimization procedure in minimizing the structural deformation of beams of different materials when subjected to different loading and end conditions using ceramic or polymeric piezo-electric actuators. The results obtained emphasize the importance of the devised rational procedure in designing beam-actuator systems with minimal elastic distortions.

  7. Determination of Kinetic Parameters and Metal Ions in Urea-Urease System Based on the Biochemical Reaction Heat Induced Laser Beam Deflection

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    A new analytical method for the determination of urea-urease system based on biochemical reaction heat induced laser beam deflection is presented in this paper. With the method, the Michaelis constant (Km) of urease and apparent inhibition constant (Ki) of some metal ion inhibitors were measured respectively. This method was also used for the quantitative determination of metal ions with satisfactory result.

  8. The Influence of Radiation Damage on the Deflection of High-Energy Beams in Bent Silicon Crystals

    CERN Document Server

    Biino, C; Doble, Niels T; Elsener, K; Gatignon, L; Grafström, P; Mikkelsen, U; Kirsebom, K; Møller, S P; Uggerhøj, Erik; Worm, T

    1996-01-01

    Experimental results obtained for deflection of 450 GeV/c protons channeling along the {111} planes in a bent, strongly irradiated silicon crystal are presented. A comparison between the deflection efficiencies in irradiated areas and non-irradiated areas in the crystal shows that irradiation by 2.4 · 1020 protons/cm2 leads to a reduction of around 30 % in deflection efficiency. As a consequence, beam-splitting and extraction from an accelerator by means of a bent crystal are feasible solutions at high energies even for intense beams and during long periods.

  9. Study of tunable resonances in laser beam divergence and beam deflection

    CERN Document Server

    Kohazi-Kis, A; Gorbe, M; Nagy, P

    2012-01-01

    New, fundamental resonant properties of laser resonators are theoretically predicted and experimentally demonstrated. These resonances occur either in the time dependence of the beam width and that of beam radius of curvature of the wavefront or in the time dependent pointing and position stability of the output light beam of a laser resonator. The resonant frequency can be tuned continuously from zero to the round-trip frequency in the first case; and from zero to the half of the round-trip frequency in the second case, by for example, moving one of the mirrors of the resonator. In both cases besides a resonant frequency its complementary frequency to the round-trip frequency is also resonant, and their shifted frequencies by multiples of the round-trip frequency are also resonant. In our experimental demonstration we measured the radiofrequency noise spectrum of the output laser beam, that was partially blocked by a knife-edge. We observed increased noise at the theoretically predicted frequencies. Similar ...

  10. Beam steering and deflecting device using step-based micro-blazed grating

    Science.gov (United States)

    Yang, Junbo; Su, Xianyu; Xu, Ping; Gu, Zheng

    2008-08-01

    The rapidly evolving demands of optical communications and optical switching systems have created a new market for high capacity all-optical beam steering and deflecting techniques. One technology potentially capable of realizing such systems uses the multistep micro-blazed grating optical beam deflectors based on binary and multiple-phase modulation methods. The micro-optical element has been fabricated by introducing very large scale integration (VLSI), stepping photolithography and reactive ion etching (RIE), which can realize beam steering, deflecting, splitting, and switching in free space, and its diffraction properties are determined by the blazed-grating parameters, such as the number of steps, grating depth, grating period, as well as blazed profile. The theoretical analysis and primarily experimental result show that this phase-type element has the advantages of high diffractive efficiency, low cross talk, small feature size, and high reliability due to nonmechanical beam steering without any moving parts. Hence it is ideally suited to applications in optical communication and optical interconnection network.

  11. Fibre-Coupling Zig-Zag Beam Deflection Technology for Investigation of Attenuation Process of Laser-Induced Shock Waves

    Institute of Scientific and Technical Information of China (English)

    ZHANG Ping; BIAN Bao-Min; LI Zhen-Hua

    2005-01-01

    @@ A novel fibre-coupling zig-zag beam deflection technology is developed to investigate the attenuation process of laser-induced shock waves in air. Utilizing ordinal reflections of probe beams by a pair of parallel mirrors,a zig-zag beam field is formed, which has eleven probe beams in the horizontal plane. When a laser-induced shock wave propagates through the testing field, it causes eleven deflection signals one after another. The whole attenuation process of the shock wave in air can be detected and illuminated clearly on one experimental curve.

  12. Implementation of Radio-Frequency Deflecting Devices for Comprehensive High-Energy Electron Beam Diagnosis

    Science.gov (United States)

    Craievich, Paolo; Petronio, Marco; Biedron, Sandra G.; Castronovo, Davide; Dal Forno, Massimo; Di Mitri, Simone; Faure, Nicolas; La Civita, Daniele; Penco, Giuseppe; Rumiz, Luca; Sturari, Luca; Vescovo, Roberto; Wang, Defa

    2015-02-01

    In next-generation light sources, high-brightness electron beams are used in a free-electron laser configuration to produce light for use by scientists and engineers in numerous fields of research. High-brightness beams are described for such light sources as having low transverse and longitudinal emittances, high peak currents, and low slice emittance and energy spread. The optimal generation and preservation of such high-brightness electron beams during the acceleration process and propagation to and through the photon-producing element is imperative to the quality and performance of the light source. To understand the electron beam's phase space in the accelerating section of a next-generation light source machine, we employed radio-frequency cavities operating in a deflecting mode in conjunction with a magnetic spectrometer and imaging system for both low (250 MeV) and high (1.2 GeV) electron energies. This high-resolution, high-energy system is an essential diagnostic for the optimization and control of the electron beam in the FERMI light source generating fully transversely and longitudinally coherent light in the VUV to soft x-ray wavelength regimes. This device is located at the end of the linear accelerator in order to provide the longitudinal phase space nearest to the entrance of the photon-producing beam-lines. Here, we describe the design, fabrication, characterization, commissioning, and operational implementation of this transverse deflecting cavity structure diagnostic system for the high-energy (1.2 GeV) regime.

  13. Implementation of a beam deflection system for studies of liquid interfaces on beamline I07 at Diamond.

    Science.gov (United States)

    Arnold, Thomas; Nicklin, Chris; Rawle, Jonathan; Sutter, John; Bates, Trevor; Nutter, Brian; McIntyre, Gary; Burt, Martin

    2012-05-01

    X-ray optics, based on a double-crystal deflection scheme, that enable reflectivity measurements from liquid surfaces/interfaces have been designed, built and commissioned on beamline I07 at Diamond Light Source. This system is able to deflect the beam onto a fixed sample position located at the centre of a five-circle diffractometer. Thus the incident angle can be easily varied without moving the sample, and the reflected beam is tracked either by a moving Pilatus 100K detector mounted on the diffractometer arm or by a stationary Pilatus 2M detector positioned appropriately for small-angle scattering. Thus the system can easily combine measurements of the reflectivity from liquid interfaces (Q(z) > 1 Å(-1)) with off-specular data collection, both in the form of grazing-incidence small-angle X-ray scattering (GISAXS) or wider-angle grazing-incidence X-ray diffraction (GIXD). The device allows operation over the energy range 10-28 keV.

  14. Directed energy deflection laboratory measurements of common space based targets

    Science.gov (United States)

    Brashears, Travis; Lubin, Philip; Hughes, Gary B.; Meinhold, Peter; Batliner, Payton; Motta, Caio; Madajian, Jonathan; Mercer, Whitaker; Knowles, Patrick

    2016-09-01

    We report on laboratory studies of the effectiveness of directed energy planetary defense as a part of the DE-STAR (Directed Energy System for Targeting of Asteroids and exploRation) program. DE-STAR and DE-STARLITE are directed energy "stand-off" and "stand-on" programs, respectively. These systems consist of a modular array of kilowatt-class lasers powered by photovoltaics, and are capable of heating a spot on the surface of an asteroid to the point of vaporization. Mass ejection, as a plume of evaporated material, creates a reactionary thrust capable of diverting the asteroid's orbit. In a series of papers, we have developed a theoretical basis and described numerical simulations for determining the thrust produced by material evaporating from the surface of an asteroid. In the DESTAR concept, the asteroid itself is used as the deflection "propellant". This study presents results of experiments designed to measure the thrust created by evaporation from a laser directed energy spot. We constructed a vacuum chamber to simulate space conditions, and installed a torsion balance that holds a common space target sample. The sample is illuminated with a fiber array laser with flux levels up to 60 MW/m2 , which allows us to simulate a mission level flux but on a small scale. We use a separate laser as well as a position sensitive centroid detector to readout the angular motion of the torsion balance and can thus determine the thrust. We compare the measured thrust to the models. Our theoretical models indicate a coupling coefficient well in excess of 100 μN/Woptical, though we assume a more conservative value of 80 μN/Woptical and then degrade this with an optical "encircled energy" efficiency of 0.75 to 60 μN/Woptical in our deflection modeling. Our measurements discussed here yield about 45 μN/Wabsorbed as a reasonable lower limit to the thrust per optical watt absorbed. Results vary depending on the material tested and are limited to measurements of 1 axis, so

  15. Directed Energy Deflection Laboratory Measurements of Asteroids and Space Debris

    Science.gov (United States)

    Brashears, T.; Lubin, P. M.

    2016-12-01

    We report on laboratory studies of the effectiveness of directed energy planetary and space defense as a part of the DE-STAR (Directed Energy System for Targeting of Asteroids and exploRation) program. DE-STAR [1][5][6] and DE-STARLITE [2][5][6] are directed energy "stand-off" and "stand-on" programs, respectively. These systems consist of a modular array of kilowatt-class lasers powered by photovoltaics, and are capable of heating a spot on the surface of an asteroid to the point of vaporization. Mass ejection, as a plume of evaporated material, creates a reactionary thrust capable of diverting the asteroid's orbit. In a series of papers, we have developed a theoretical basis and described numerical simulations for determining the thrust produced by material evaporating from the surface of an asteroid [1][2][3][4][5][6]. In the DE-STAR concept, the asteroid itself is used as the deflection "propellant". This study presents results of experiments designed to measure the thrust created by evaporation from a laser directed energy spot. We constructed a vacuum chamber to simulate space conditions, and installed a torsion balance that holds an "asteroid" or a space debris sample. The sample is illuminated with a fiber array laser with flux levels up to 60 MW/m2 which allows us to simulate a mission level flux but on a small scale. We use a separate laser as well as a position sensitive centroid detector to readout the angular motion of the torsion balance and can thus determine the thrust. We compare the measured thrust to the models. Our theoretical models indicate a coupling coefficient well in excess of 100 µN/Woptical, though we assume a more conservative value of 80 µN/Woptical and then degrade this with an optical "encircled energy" efficiency of 0.75 to 60 µN/Woptical in our deflection modeling. Our measurements discussed here yield about 60 µN/Wabsorbed as a reasonable lower limit to the thrust per optical watt absorbed.

  16. Pull-in analysis of non-uniform microcantilever beams under large deflection

    Science.gov (United States)

    Singh, Sajal Sagar; Pal, Prem; Pandey, Ashok Kumar

    2015-11-01

    Cantilever beams under the influence of electrostatic force form an important subclass of microelectromechanical system (MEMS) and nanoelectromechanical system. Most of the studies concerning these micro-nano resonators are centered around uniform cantilever beams. In this paper, we have investigated another class of micro-resonators consisting of non-uniform cantilever beams. The study is focused around investigating pull-in voltage and resonance frequency of non-uniform cantilever beams when they operate in the linear regime about different static equilibriums. In this paper, we term this frequency as "linear frequency." Calculation of the linear frequency is done at different static equilibriums corresponding to different DC voltages. We have studied two classes of beams, one with increasing cross sectional area from the clamped edge (diverging beam) and other with decreasing cross sectional area from the clamped edge (converging beam). Within each class, we have investigated beams with linear as well as quartic variation in width. We start by obtaining Euler beam equation for non-uniform cantilever beams considering large deflection and their corresponding exact mode shapes from the linear equation. Subsequently, using the Galerkin method based on single mode approximation, we obtain static and dynamic modal equations for finding pull-in voltage and resonance frequency as a function of DC voltage, respectively. We found that the linear frequency of converging beams increases with increase in non-uniform parameter (α) while those of diverging beams decreases with α. A similar trend is observed for pull-in voltage. Within the converging class, beams with quartic variation in width show significant increase in both frequency and pull-in voltage as compared to corresponding linearly tapered beams. In quantitative terms, converging beams with quartic variation in width and α=-0.6 showed an increase in linear frequency by a factor of 2.5 times and pull-in voltage

  17. ESTIMATION OF VERTICAL DEFLECTIONS IN CONCRETE BEAMS THROUGH DIGITAL CLOSE RANGE PHOTOGRAMMETRY

    Directory of Open Access Journals (Sweden)

    I. Detchev

    2012-09-01

    Full Text Available Deformation monitoring, and in general structural health monitoring, of civil infrastructure systems is important in terms of both safety and serviceability. Traditionally, large structures have been monitored using surveying techniques, while fine-scale monitoring of structural components has been done with geotechnical instrumentation. This paper reviews the advantages and disadvantages of using remote sensing methods, such as terrestrial laser scanning and digital close range photogrammetry, for the purposes of precise 3D reconstruction and the estimation of deflections in structural materials. It is also shown how a low-cost setup of multiple digital cameras and projectors can be used for the monitoring of concrete beams subjected to different loading conditions by a hydraulic actuator. The photogrammetric system used does not require any physical targets other than for the purposes of establishing the relative orientation between the involved cameras. The setup was tested in two experiments, and the beam deflections resulted from the photogrammetric system were compared to the ones from a set of one-dimensional laser transducers and a terrestrial laser scanner. The experiments proved that it was possible to detect sub-millimetre level deformations given the used equipment and the geometry of the setup.

  18. Exploring the Spatial Resolution of the Photothermal Beam Deflection Technique in the Infrared Region

    CERN Document Server

    Seidel, Wolfgang

    2004-01-01

    In photothermal beam deflection spectroscopy (PTBD) generating and detection of thermal waves occur generally in the sub-millimeter length scale. Therefore, PTBD provides spatial information about the surface of the sample and permits imaging and/or microspectrometry. Recent results of PTBD experiments are presented with a high spatial resolution which is near the diffraction limit of the infrared pump beam (CLIO-FEL). We investigated germanium substrates showing restricted O+-doped regions with an infrared absorption line at a wavelength around 11.6 microns. The spatial resolution was obtained by strongly focusing the probe beam (i.e. a HeNe laser) on a sufficiently small spot. The strong divergence makes it necessary to refocus the probe beam in front of the position detector. The influence of the focusing elements on spatial resolution and signal-to-noise ratio is discussed. In future studies we expect an enhanced spatial resolution due to an extreme focusing of the probe beam leading to a highly sensitive...

  19. Refraction of $e^-$ beams due to plasma lensing at a plasma-vacuum interface -- applied to beam deflection in a Copper cell with electrical RF-breakdown plasma

    CERN Document Server

    Sahai, Aakash A

    2014-01-01

    We formulate a possible description of the deflection of a relativistic $e^-$ beam in an inhomogeneous copper plasma, encountered by the beam when propagating through a accelerating cell that has undergone a high electric-field RF-breakdown. It is well known that an inhomogeneous plasma forms and may last for up to a few micro-seconds, until recombination in an accelerating structure where a field-emission triggers melting and ionization of RF-cell wall deformity. We present a preliminary model for the beam deflection due to collective plasma response based upon the beam density, plasma density and interaction length.

  20. Disruption effects on the beam size measurement

    Energy Technology Data Exchange (ETDEWEB)

    Raimondi, P.; Decker, F.J.; Chen, P.

    1995-06-01

    At the SLC Final Focus with higher currents and smaller beam sizes, the disruption parameter D{sub y} is close to one and so the pinch effect should produce a luminosity enhancement. Since a flat beam-beam function is fit to deflection scan data to measure the beam size, disruption can affect the measurement. Here the authors discuss the quantitative effects of disruption for typical SLC beam parameters. With 3.5 10{sup 10} particles per pulse, bunch length of 0.8 mm and beam sizes of 2.1 {mu}m horizontally and 0.55 {mu}m vertically, the measured vertical size can be as much as 25% bigger than the real one. Furthermore during the collision the spot size actually decrease, producing an enhancement factor H{sub D} of about 1.25. This would yield to a true luminosity which is 1.6 times that which is estimated from the beam-beam deflection fit.

  1. A systematic analysis of the influence of the surrounding media in the photothermal beam deflection signal

    Energy Technology Data Exchange (ETDEWEB)

    Goeren, A; Prior, P; Macedo, F, E-mail: fmacedo@fisica.uminho.p [Physics Department, University of Minho, Campus de Gualtar, 4710-057 Braga (Portugal)

    2010-03-01

    The photothermal beam deflection (PDS) technique was tested for low thermal diffusivity materials. The effect of using different liquids as surrounding media was studied in a systematic way. The fundamental experimental parameters, like the pump beam power and the modulation frequency were also studied in order to find out the best combination that still allows us to get good signals. Due to the complexity of the optical alignment required, the usual mirage setup was adapted in order to allow the decoupling of the alignment of the cell containing the liquid and the sample holder. Simple, straightforward methods (like e.g. the phase method) were used for the thermal diffusivity determination of solids once the thermal diffusivity of the liquids used is always much lower than that of solids. The obtained values for the thermal diffusivity of test samples allow us to conclude that besides being possible to use any of the studied liquids as surrounding medium, ethanol is clearly the best choice, avoiding health problems related to CCl{sub 4}, which is the standard choice for PDS and PDS spectroscopy experiments, and technical/physical problems related to water and acetone. Modulation frequencies around 8 Hz combined with a pump beam power below 15 mW were proved to be the ideal conditions for this kind of experiment. The very low pump beam power required is also an important issue when talking about non-destructive analysis.

  2. Cantilever deflection measurement and actuation by an nterdigitated transducer

    NARCIS (Netherlands)

    Strambini, E.; Piazza, V.; Pingue, P.; Biasiol, G.; Sorba, L.; Beltram, F.

    2010-01-01

    A scheme that allows all-electrical high-bandwidth readout of a cantilever deflection by means of an integrated interdigitated transducer is presented. The present approach takes advantage of the piezoelectricity of the chosen cantilever substrate material to generate and detect surface-acoustic-wav

  3. Comparing deflection measurements of a magnetically steerable catheter using optical imaging and MRI

    Energy Technology Data Exchange (ETDEWEB)

    Lillaney, Prasheel, E-mail: Prasheel.Lillaney@ucsf.edu; Caton, Curtis; Martin, Alastair J.; Losey, Aaron D.; Evans, Leland; Saeed, Maythem; Cooke, Daniel L.; Wilson, Mark W.; Hetts, Steven W. [Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California 94143 (United States)

    2014-02-15

    Purpose: Magnetic resonance imaging (MRI) is an emerging modality for interventional radiology, giving clinicians another tool for minimally invasive image-guided interventional procedures. Difficulties associated with endovascular catheter navigation using MRI guidance led to the development of a magnetically steerable catheter. The focus of this study was to mechanically characterize deflections of two different prototypes of the magnetically steerable catheterin vitro to better understand their efficacy. Methods: A mathematical model for deflection of the magnetically steerable catheter is formulated based on the principle that at equilibrium the mechanical and magnetic torques are equal to each other. Furthermore, two different image based methods for empirically measuring the catheter deflection angle are presented. The first, referred to as the absolute tip method, measures the angle of the line that is tangential to the catheter tip. The second, referred to the base to tip method, is an approximation that is used when it is not possible to measure the angle of the tangent line. Optical images of the catheter deflection are analyzed using the absolute tip method to quantitatively validate the predicted deflections from the mathematical model. Optical images of the catheter deflection are also analyzed using the base to tip method to quantitatively determine the differences between the absolute tip and base to tip methods. Finally, the optical images are compared to MR images using the base to tip method to determine the accuracy of measuring the catheter deflection using MR. Results: The optical catheter deflection angles measured for both catheter prototypes using the absolute tip method fit very well to the mathematical model (R{sup 2} = 0.91 and 0.86 for each prototype, respectively). It was found that the angles measured using the base to tip method were consistently smaller than those measured using the absolute tip method. The deflection angles measured

  4. Beam Measurements in Storage Rings

    Science.gov (United States)

    Hofmann, Albert

    1996-05-01

    Beam measurements in storage rings are made to diagnose performance limitations and to gain knowledge of the beam behavior in view of improvements and to the benefit for other machines. In beam optics the measurement of the orbit or the trajectory with beam position monitors distributed around the ring reveals deflection errors. The overall focusing is checked by measuring the betatron frequency (tune) using a pulse or continuous excitation of the oscillation. Observing this oscillation with all the beam position monitors around the ring the beta function and the betatron phase advance are obtained. This measurement done for different momenta, i.e. RF-frequencies, gives the local chromaticity and its correction. The tune dependence on quadrupole strength gives the value of the local beta function. Synchrotron radiation is a powerful diagnostics tool and can give the beam cross section. Beam instabilities are investigated with similar methods. The growth or damping rates and frequencies of betatron and synchrotron oscillations, observed as a function of intensity, give a convolution of the resistive and reactive part of the transverse and longitudinal impedance with the spectrum of the oscillation mode. Coupled bunch instabilities are caused by narrow band impedances at particular frequencies while single traversal effects, including energy loss and bunch lengthening, are due to a broad band impedance. A model of the impedance can be constructed from such measurements done with different bunch lengths, tunes and other parameters. In some cases the element causing an instability can be identified. The dependence of the orbit and phase advance around the ring on intensity can give the location of impedances. To probe the impedance at very high frequencies the effects on very short bunches or the energy loss of a continuous beam due to its Schottky noise are measured. The beam energy, usually known from magnetic measurements, can be obtained directly with high

  5. Study of laser-induced plasma shock waves by the probe beam deflection technique

    Institute of Scientific and Technical Information of China (English)

    Yan Qian; Jian Lu; Xiaowu Ni

    2009-01-01

    Laser probe beam deflection technique is used for the analysis of laser-induced plasma shock waves in air and distilled water.The temporal and spatial variations of the parameters on shock fronts are studied as funotions of focal lens position and laser energy.The influences of the characteristics of media are investigated on the well-designed experimental setup.It is found that the shock wave in distilled water attenuates to an acoustic wave faster than in air under the same laser energy.Good agreement is obtained between our experimental results and those attained with other techniques.This technique is versatile,economic,and simple to implement,being a pronmising diagnostic tool for pulsed laser processing.

  6. Approximations for Large Deflection of a Cantilever Beam under a Terminal Follower Force and Nonlinear Pendulum

    Directory of Open Access Journals (Sweden)

    H. Vázquez-Leal

    2013-01-01

    Full Text Available In theoretical mechanics field, solution methods for nonlinear differential equations are very important because many problems are modelled using such equations. In particular, large deflection of a cantilever beam under a terminal follower force and nonlinear pendulum problem can be described by the same nonlinear differential equation. Therefore, in this work, we propose some approximate solutions for both problems using nonlinearities distribution homotopy perturbation method, homotopy perturbation method, and combinations with Laplace-Padé posttreatment. We will show the high accuracy of the proposed cantilever solutions, which are in good agreement with other reported solutions. Finally, for the pendulum case, the proposed approximation was useful to predict, accurately, the period for an angle up to 179.99999999∘ yielding a relative error of 0.01222747.

  7. Ludwig-Soret effect of non-ionic surfactant aqueous solution studied by beam deflection method

    Science.gov (United States)

    Maeda, Kousaku; Kita, Rio; Shinyashiki, Naoki; Yagihara, Shin

    2013-02-01

    We have studied the thermal diffusion of non-ionic surfactant aqueous solutions by a beam deflection method. The thermal diffusion of pentaethylene glycol monododecyl ether (C12E5) and hexaethylene glycol monododecyl ether (C12E6) is studied in the concentration range of 1.0-99.0 wt% and in the temperature range of 20.0-35.0 °C. A stable temperature gradient is applied to the solution, where solute molecules shift to the cold side of the solution for lowconcentration samples. The concentration dependence of the Soret coefficient ST of the C12E6 aqueous solution shows a sign inversion behavior. At all concentrations, the developed concentration gradient is proportionally related to the applied temperature gradient. The results confirm that the magnitude of ST has no temperature gradient dependence under the studied experimental conditions.

  8. Large deflections and vibrations of a tip pulled beam with variable transversal section

    Science.gov (United States)

    Kurka, P.; Izuka, J.; Gonzalez, P.; Teixeira, L. H.

    2016-10-01

    The use of long flexible probes in outdoors exploration vehicles, as opposed to short and rigid arms, is a convenient way to grant easier access to regions of scientific interest such as terrain slopes and cliff sides. Longer and taller arms can also provide information from a wider exploration horizon. The drawback of employing long and flexible exploration probes is the fact that its vibration is not easily controlled in real time operation by means of a simple analytic linear dynamic model. The numerical model required to describe the dynamics of a very long and flexible structure is often very large and of slow computational convergence. The present work proposes a simplified numerical model of a long flexible beam with variable cross section, which is statically deflected by a pulling cable. The paper compares the proposed simplified model with experimental data regarding the static and dynamic characteristics of a beam with variable cross section. The simulations show the effectiveness of the simplified dynamic model employed in an active control loop to suppress tip vibrations of the beam.

  9. Relativistic Stern-Gerlach Deflection

    CERN Document Server

    Talman, Richard

    2016-01-01

    Modern advances in polarized beam control should make it possible to accurately measure Stern-Gerlach (S-G) deflection of relativistic beams. Toward this end a relativistically covariant S-G formalism is developed that respects the opposite behavior under inversion of electric and magnetic fields. Not at all radical, or even new, this introduces a distinction between electric and magnetic fields that is not otherwise present in pure Maxwell theory. Experimental configurations (mainly using polarized electron beams passing through magnetic or electric quadrupoles) are described. Electron beam preparation and experimental methods needed to detect the extremely small deflections are discussed.

  10. Influence of incoherent scattering on stochastic deflection of high-energy negative particle beams in bent crystals

    Energy Technology Data Exchange (ETDEWEB)

    Kirillin, I.V. [Akhiezer Institute for Theoretical Physics, National Science Center ' ' Kharkov Institute of Physics and Technology' ' , Kharkov (Ukraine); Shul' ga, N.F. [Akhiezer Institute for Theoretical Physics, National Science Center ' ' Kharkov Institute of Physics and Technology' ' , Kharkov (Ukraine); V.N. Karazin Kharkov National University, Kharkov (Ukraine); Bandiera, L. [INFN Sezione di Ferrara, Ferrara (Italy); Guidi, V.; Mazzolari, A. [INFN Sezione di Ferrara, Ferrara (Italy); Universita degli Studi di Ferrara, Dipartimento di Fisica e Scienze della Terra, Ferrara (Italy)

    2017-02-15

    An investigation on stochastic deflection of high-energy negatively charged particles in a bent crystal was carried out. On the basis of analytical calculation and numerical simulation it was shown that there is a maximum angle at which most of the beam is deflected. The existence of a maximum, which is taken in the correspondence of the optimal radius of curvature, is a novelty with respect to the case of positively charged particles, for which the deflection angle can be freely increased by increasing the crystal length. This difference has to be ascribed to the stronger contribution of incoherent scattering affecting the dynamics of negative particles that move closer to atomic nuclei and electrons. We therefore identified the ideal parameters for the exploitation of axial confinement for negatively charged particle beam manipulation in future high-energy accelerators, e.g., ILC or muon colliders. (orig.)

  11. Nonlinear flexural waves and chaos behavior in finite-deflection Timoshenko beam

    Institute of Scientific and Technical Information of China (English)

    Shan-yuan ZHANG; Zhi-fang LIU

    2010-01-01

    Based on the Timoshenko beam theory,the finite-deflection and the axial inertia are taken into account,and the nonlinear partial differential equations for flexural waves in a beam are derived. Using the traveling wave method and integration skills,the nonlinear partial differential equations can be converted into an ordinary differential equation. The qualitative analysis indicates that the corresponding dynamic system has a heteroclinic orbit under a certain condition. An exact periodic solution of the nonlinear wave equation is obtained using the Jacobi elliptic function expansion. When the modulus of the Jacobi elliptic function tends to one in the degenerate case,a shock wave solution is given. The small perturbations are further introduced,arising from the damping and the external load to an original Hamilton system,and the threshold condition of the existence of the transverse heteroclinic point is obtained using Melnikov's method. It is shown that the perturbed system has a chaotic property under the Smale horseshoe transform.

  12. All-optical optoacoustic microscopy based on probe beam deflection technique

    Directory of Open Access Journals (Sweden)

    Saher M. Maswadi

    2016-09-01

    Full Text Available Optoacoustic (OA microscopy using an all-optical system based on the probe beam deflection technique (PBDT for detection of laser-induced acoustic signals was investigated as an alternative to conventional piezoelectric transducers. PBDT provides a number of advantages for OA microscopy including (i efficient coupling of laser excitation energy to the samples being imaged through the probing laser beam, (ii undistorted coupling of acoustic waves to the detector without the need for separation of the optical and acoustic paths, (iii high sensitivity and (iv ultrawide bandwidth. Because of the unimpeded optical path in PBDT, diffraction-limited lateral resolution can be readily achieved. The sensitivity of the current PBDT sensor of 22 μV/Pa and its noise equivalent pressure (NEP of 11.4 Pa are comparable with these parameters of the optical micro-ring resonator and commercial piezoelectric ultrasonic transducers. Benefits of the present prototype OA microscope were demonstrated by successfully resolving micron-size details in histological sections of cardiac muscle.

  13. Analysis of Deflection Problems of Large-span Continuous Rigid Frame Bridge and Prevention Measures

    Directory of Open Access Journals (Sweden)

    Chen Dong

    2015-01-01

    Full Text Available The large-span continuous rigid frame bridge is a kind of common structural form in long-span bridges of our country, but one of the main diseases of these bridges is the excessive deflection in the mid-span, which seriously affects the safety of the structure. This paper makes a comprehensive analysis for the causes of the excessive deflection, and lists the commonly-used control measures in engineering. Simultaneously, new improvement measures and the comparative analysis of before-and-after improvements are put forward on this basis. However, these measures can be used to inhibit deflection in a certain extent, but cannot avoid the occurrence of deflection completely.

  14. A surface work function measurement technique utilizing constant deflected grazing electron trajectories: oxygen uptake on Cu(001).

    Science.gov (United States)

    Ermakov, A V; Ciftlikli, E Z; Syssoev, S E; Shuttleworth, I G; Hinch, B J

    2010-10-01

    We report on the application of a novel nondestructive in-vacuum technique for relative work function measurements, employing a grazing incidence electron deflection above a sample with a planar surface. Two deflected electron beam detectors are used as a position sensitive detector to control feedback to the sample potential as the sample work function changes. With feedback the sample potential exactly follows the surface sample-size averaged work function variation, so that the deflected beam trajectory remains stable. We also discuss methods to optimize the initial electron trajectories for this method, so as to minimize unwanted effects such as from uncontrolled external magnetic fields. As the electron beam does not impinge on the surface in this new technique electron induced desorption, ionization, dissociation, and/or decomposition is not induced at the interface. Importantly also the technique allows for free access to the surfaces enabling simultaneous deposition/evaporation and/or application of other surface characterization methods. We demonstrate its application in concurrent measurements of helium atom reflectivity and work function changes taking place during molecular oxygen exposure of a Cu(001) surface. A work function measurement sensitivity and stability is demonstrated at ∼10 mV at a sampling rate of 1 Hz and after application of an ∼7 s smoothing routine. In comparison to the helium atom reflectivity measurements, the work function measurements are more sensitive to the initial O uptake, and less so to the final coverage variations and possible surface reordering at higher O coverages.

  15. Probe beam deflection studies of nanostructured catalyst materials for fuel cells.

    Science.gov (United States)

    García, G; Bruno, M M; Planes, G A; Rodriguez, J L; Barbero, C A; Pastor, E

    2008-11-28

    Probe beam deflection (PBD) techniques, both as cyclic voltadeflectometry (CVD) and chronodeflectometry (CD), were applied for the first time to the study of the electrochemistry of nanostructured Pt materials which are commonly used as electrocatalysts in fuel cells. The electrochemical surface reactions, including faradaic processes, double layer charging and specific anion adsorption were easily detected. Quantitative analysis of the chronodeflectometric data made possible to elucidate the dynamics of double layer charging in such materials and to determine the potential of zero charge (pzc) of the metal present either as a monolithic mesoporous material or as metal nanoparticles supported on carbon. The electro-oxidation of CO, adsorbed on nanostructured Pt, was also studied by CVD and CD being able to detect the formation of CO2 and H3O+ related with the nucleation and growth process which controls the rate of CO stripping. The interplay of Pt oxide formation and COad electrooxidation, both in potential and time, was detected indicating possible application of the technique to other electrocatalysts.

  16. Optical Beam Deflection Based AFM with Integrated Hardware and Software Platform for an Undergraduate Engineering Laboratory

    Directory of Open Access Journals (Sweden)

    Siu Hong Loh

    2017-02-01

    Full Text Available Atomic force microscopy (AFM has been used extensively in nanoscience research since its invention. Recently, many teaching laboratories in colleges, undergraduate institutions, and even high schools incorporate AFM as an effective teaching tool for nanoscience education. This paper presents an optical beam deflection (OBD based atomic force microscope, designed specifically for the undergraduate engineering laboratory as a teaching instrument. An electronic module for signal conditioning was built with components that are commonly available in an undergraduate electronic laboratory. In addition to off-the-shelf mechanical parts and optics, the design of custom-built mechanical parts waskept as simple as possible. Hence, the overall cost for the setup is greatly reduced. The AFM controller was developed using National Instruments Educational Laboratory Virtual Instrumentation Suite (NI ELVIS, an integrated hardware and software platform which can be programmed in LabVIEW. A simple yet effective control algorithm for scanning and feedback control was developed. Despite the use of an educational platform and low-cost components from the undergraduate laboratory, the developed AFM is capable of performing imaging in constant-force mode with submicron resolution and at reasonable scanning speed (approximately 18 min per image. Therefore, the AFM is suitable to be used as an educational tool for nanoscience. Moreover, the construction of the system can be a valuable educational experience for electronic and mechanical engineering students.

  17. LIGHT SOURCE: RF deflecting cavity for bunch length measurement in Tsinghua Thomson scattering X-ray source

    Science.gov (United States)

    Shi, Jia-Ru; Chen, Huai-Bi; Tang, Chuan-Xiang; Huang, Wen-Hui; Du, Ying-Chao; Zheng, Shu-Xin; Ren, Li

    2009-06-01

    An RF deflecting cavity used for bunch length measurement has been designed and fabricated at Tsinghua University for the Thomson Scattering X-Ray Source. The cavity is a 2856 MHz, π-mode, 3-cell standing-wave cavity, to diagnose the 3.5 MeV beam produced by photocathode electron gun. With a larger power source, the same cavity will again be used to measure the accelerated beam with energy of 50 MeV before colliding with the laser pulse. The RF design using MAFIA for both the cavity shape and the power coupler is reviewed, followed by presenting the fabrication procedure and bench measurement results of two cavities.

  18. Investigation of beam deflection reduction and multi-beamlet focus at a large-area negative ion source for a neutral beam injector with 3-D beam trajectory simulation

    CERN Document Server

    Tanaka, M; Asano, E; Oka, Y; Osakabe, M; Tsumori, K; Kaneko, O; Yamashita, Y

    2000-01-01

    We investigated the reduction of ion beam deflection caused by electron deflection magnets, and focus of multi-beamlets at a large-area negative ion source of a neutral beam injector (NBI) in order to reduce beam loss during long-distance beam transport (>10 m) and beam injection into a nuclear fusion device. The electrostatic lens effect by displacement of the beam extraction aperture of a grounded grid (GG) was utilized for the beam deflection reduction and the multi-beamlet focus. We proposed an analysis process to adjust the aperture displacement which avoids beam collision with the GG by too much displacement. The analysis process includes a 3-D beam trajectory simulation used for analyzing the beam deflection angle and beam radius as well as theoretical calculations, which are used to calculate the aperture displacement based on the 3-D simulation results. Applicability of the analysis process was examined for a large-area high-current H sup - ion source of an NBI (0.25 mx1.25 m, 40 A, 180 keV). The ana...

  19. Simultaneous Optical Measurements of Axial and Tangential Steady-State Blade Deflections

    Science.gov (United States)

    Kurkov, Anatole P.; Dhadwal, Harbans S.

    1999-01-01

    Currently, the majority of fiber-optic blade instrumentation is being designed and manufactured by aircraft-engine companies for their own use. The most commonly employed probe for optical blade deflection measurements is the spot probe. One of its characteristics is that the incident spot on a blade is not fixed relative to the blade, but changes depending on the blade deformation associated with centrifugal and aerodynamic loading. While there are geometrically more complicated optical probe designs in use by different engine companies, this paper offers an alternate solution derived from a probe-mount design feature that allows one to change the probe axial position until the incident spot contacts either a leading or a trailing edge. By tracing the axial position of either blade edge one is essentially extending the deflection measurement to two dimensions, axial and tangential. The blade deflection measurements were obtained during a wind tunnel test of a fan prototype.

  20. The deflection of light induced by the Sun's gravitational field and measured with geodetic VLBI

    CERN Document Server

    Titov, O

    2015-01-01

    The Sun's gravitational field deflects the apparent positions of close objects in accordance with the formulae of general relativity. Optical astrometry is used to test the prediction, but only with the stars close to the Sun and only during total Solar eclipses. Geodetic Very Long Baseline Interferometry (VLBI) is capable of measuring the deflection of the light from distant radio sources anytime and across the whole sky. We show that the effect of light deflection is equivalent to the gravitational delay calculated during the reduction of VLBI data. All reference radio sources display an annual circular motion with the magnitude proportional to their ecliptic latitude. In particular, radio sources near the ecliptic pole draw an annual circle with magnitude of 4 mas. This effect could be easily measured with the current precision of the geodetic VLBI data.

  1. Sagnac interferometer for photothermal deflection spectroscopy.

    Science.gov (United States)

    Shiokawa, Naoyuki; Mizuno, Yuki; Tsuchiya, Harumasa; Tokunaga, Eiji

    2012-07-01

    Photothermal deflection spectroscopy is combined with a Sagnac interferometer to enhance the sensitivity of the absorption measurement by converting the photothermal beam deflection effect into the light intensity change by the interference effect. Because of stable light interference due to the common path, the signal intensity can be amplified without increasing the noise by extending the optical path length between a sample and a photodetector. The sensitivity is further improved by the use of focusing optics and double-pass geometry. This makes photothermal deflection spectroscopy applicable to any kind of material in the whole visible region with a xenon lamp for excitation and water or air as a deflection medium.

  2. Dynamic Modeling of Pavements with Application to Deflection Measurements

    DEFF Research Database (Denmark)

    Madsen, Stine Skov

    Pavement surface deflection measurements are the primary means of evaluating the bearing capacity of a pavement. The most common type of device used for measuring pavement surface deflections is the Falling Weight Deflectometer (FWD). However, increasing attention has been given to the Rolling Wheel...... Deflectometer (RWD) type of device due to its ability to measure deflections continuously while driving at traffic speed. To be able to properly interpret deflection measurements from an RWD device, more knowledge about the structural behavior of a pavement when subjected to transient dynamic loads moving...

  3. New deflected-beam gauge for pressures below 10/sup -12/ Torr

    CERN Document Server

    Blechschmidt, Diether

    1975-01-01

    A new ionization gauge for measurement of total gas pressures between 10/sup -12/ torr and 10/sup -14/ torr is described. The gauge's main features are a pair of collimating slots below the grid structure, two concentric hemi-spherical deflecting electrodes and a channel electron multiplier which detects low-energy ions passing through the deflector system. The detection of low-energy ions allows discrimination against desorbed ions (which are more energetic), while spurious signals due to X-rays may also be rejected. The channel electron multiplier leads to gauge sensitivities which are much higher than those of ordinary ionization gauges. The gauge has been tested down to 4*10/sup -13/ torr and found to have sensitivities of 1.5*10/sup 17/ and 8*10/sup 16 / counts/s.A.torr for N/sub 2/ and H/sub 2/ respectively. For a channel electron multiplier gain of 10/sup 7/ the gauge sensitivity is thus approximately=10/sup 5//torr. (17 refs).

  4. A Novel Deflection Method for Measuring the Growth Stress of Thermally Growing Oxide Scales

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    A kind of new deflection technique has been developed for measuring the growth stress of thermally growing oxide scales duringhigh temperature oxidation of alloys. The average growth stresses in oxide scales such as Al2O3, NiO and Cr2O3 formed onthe surface of the superalloys can be investigated by this technique. Unlike the comventional deflection method, the novelmethod does not need to apply a coating for preventing one main face of thin strip specimen from oxidizing and can be usedunaer tne condition of longer time and higher temperature.

  5. Teach Deflection Concepts with Hacksaw Blades and Rubber Bands

    Science.gov (United States)

    Roman, Harry T.

    2013-01-01

    Technology and engineering educators can use a simple hacksaw blade to help students learn about deflection, as that which occurs in a beam. Here the beam is fixed at one end and allowed to deflect in a manner that is easy to see and measure--the hacksaw blade represents a cantilever, an overhanging structure. This simple and very inexpensive…

  6. Comparative research on the methods for measuring the mode deflection angle of cylindrical resonator gyroscope

    Science.gov (United States)

    Wang, Kai; Fan, Zhenfang; Wang, Dongya; Wang, Yanyan; Pan, Yao; Qu, Tianliang; Xu, Guangming

    2016-10-01

    The existence of mode deflection angle in the cylindrical resonator gyroscope (CRG) leads to the signal drift on the detecting nodes of the gyro vibration and significantly decreases the performance of the CRG. Measuring the mode deflection angle efficiently is the foundation of tuning for the imperfect cylindrical shell resonator. In this paper, an optical method based on the measuring gyroscopic resonator's vibration amplitude with the laser Doppler vibrometer and an electrical method based on measuring the output voltage of the electrodes on the resonator are both presented to measure the mode deflection angle. Comparative experiments were implemented to verify the methodology and the results show that both of the two methods could recognize the mode deflection angle efficiently. The precision of the optical method relies on the number and position of testing points distributed on the resonator. The electrical method with simple circuit shows high accuracy of measuring in a less time compared to the optical method and its error source arises from the influence of circuit noise as well as the inconsistent distribution of the piezoelectric electrodes.

  7. DEFLECTION OF A HETEROGENEOUS WIDE-BEAM UNDER UNIFORM PRESSURE LOAD

    Energy Technology Data Exchange (ETDEWEB)

    T. V. Holschuh; T. K. Howard; W. R. Marcum

    2014-07-01

    Oregon State University (OSU) and the Idaho National Laboratory (INL) are currently collaborating on a test program which entails hydro-mechanical testing of a generic plate type fuel element, or generic test plate assembly (GTPA), for the purpose of qualitatively demonstrating mechanical integrity of uranium-molybdenum monolithic plates as compared to that of uranium aluminum dispersion, and aluminum fuel plates onset by hydraulic forces. This test program supports ongoing work conducted for/by the Global Threat Reduction Initiative (GTRI) Fuels Development Program. This study’s focus supports the ongoing collaborative effort by detailing the derivation of an analytic solution for deflection of a heterogeneous plate under a uniform, distributed load in order to predict the deflection of test plates in the GTPA. The resulting analytical solutions for three specific boundary condition sets are then presented against several test cases of a homogeneous plate. In all test cases considered, the results for both homogeneous and heterogeneous plates are numerically identical to one another, demonstrating correct derivation of the heterogeneous solution. Two additional problems are presents herein that provide a representative deflection profile for the plates under consideration within the GTPA. Furthermore, qualitative observations are made about the influence of a more-rigid internal fuel-meat region and its influence on the overall deflection profile of a plate. Present work is being directed to experimentally confirm the analytical solution’s results using select materials.

  8. The adhesive potential of dentin bonding systems assessed using cuspal deflection measurements and cervical microleakage scores.

    Science.gov (United States)

    Sultan, Ahmed; Moorthy, Advan; Fleming, Garry J P

    2014-10-01

    To assess the cuspal deflection and cervical microleakage of standardized mesio-occluso-distal (MOD) cavities restored with a dimethacrylate resin-based-composite (RBC) placed with one 3-step, one 2-step and three 1-step bonding systems and compared with the unbound condition. Forty-eight sound maxillary premolar teeth with standardized MOD cavities were randomly allocated to six groups. Restoration was performed in eight oblique increments using a quartz-tungsten-halogen (QTH) light curing unit (LCU) with the bonding condition as the dependent variable. Buccal and palatal cuspal deflections were recorded post-irradiation using a twin channel deflection measuring gauge at 0, 30, 60 and 180s. Following restoration, the teeth were thermocycled, immersed in a 0.2% basic fuchsin dye for 24h, sectioned and examined for cervical microleakage assessment. The mean total cuspal deflection measurements with the one 3-step, one 2-step and three 1-step bonding systems were 11.26 (2.56), 10.95 (2.16), 10.03 (2.05) (Futurabond(®) DC SingleDose), 6.37 (1.37) (Adper™ Prompt™ L-Pop™), 8.98 (1.34) μm (All-Bond SE(®)), respectively when compared with the unbound condition (6.46 (1.88) μm) The one-way ANOVA of the total cuspal deflection measurements identified statistical differences (pbonding system although differences between the bonding systems were evident (pbonding technologies available to practitioners for RBCs. Poorly performing adhesives can be identified which indicated the technique may be useful as a screening tool for assessing existing and new bonding technologies which offers the potential to limit complications routinely encountered with Class II RBC restorations. Copyright © 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  9. Deflection analysis of reinforced concrete beams strengthened with carbon fibre reinforced polymer under long-term load action

    Institute of Scientific and Technical Information of China (English)

    Mykolas DAUGEVI(C)IUS; Juozas VALIVONIS; Gediminas MAR(C)IUKAITIS

    2012-01-01

    This paper presents the results of an experimental research on reinforced concrete beams strengthened with an external carbon fibre reinforced polymer (CFRP) layer under long-term load action that lasted for 330 d.We describe the characteristics of deflection development of the beams strengthened with different additional anchorages of the external carbon fibre composite layer during the period of interest.The conducted experiments showed that the additional anchorage influences the slip of the extemal layer with respect to the strengthened element.Thus,concrete and carbon fibre composite interface stiffness decreases with a long-term load action.Therefore,the proposed method of analysis based on the built-up-bars theory can be used to estimate concrete and carbon fibre composite interface stiffness in the case of long-term load.

  10. Enthalpy changes during photosynthetic water oxidation tracked by time-resolved calorimetry using a photothermal beam deflection technique.

    Science.gov (United States)

    Krivanek, Roland; Dau, Holger; Haumann, Michael

    2008-03-01

    The energetics of the individual reaction steps in the catalytic cycle of photosynthetic water oxidation at the Mn(4)Ca complex of photosystem II (PSII) are of prime interest. We studied the electron transfer reactions in oxygen-evolving PSII membrane particles from spinach by a photothermal beam deflection technique, allowing for time-resolved calorimetry in the micro- to millisecond domain. For an ideal quantum yield of 100%, the enthalpy change, DeltaH, coupled to the formation of the radical pair Y(Z)(.+)Q(A)(-) (where Y(Z) is Tyr-161 of the D1 subunit of PSII) is estimated as -820 +/- 250 meV. For a lower quantum yield of 70%, the enthalpy change is estimated to be -400 +/- 250 meV. The observed nonthermal signal possibly is due to a contraction of the PSII protein volume (apparent DeltaV of about -13 A(3)). For the first time, the enthalpy change of the O(2)-evolving transition of the S-state cycle was monitored directly. Surprisingly, the reaction is only slightly exergonic. A value of DeltaH(S(3)-->S(0)) of -210 meV is estimated, but also an enthalpy change of zero is within the error range. A prominent nonthermal photothermal beam deflection signal (apparent DeltaV of about +42 A(3)) may reflect O(2) and proton release from the manganese complex, but also reorganization of the protein matrix.

  11. Neutron beam measurement dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Amaro, C.R. [Idaho National Engineering Lab., Idaho Falls, ID (United States)

    1995-11-01

    This report describes animal dosimetry studies and phantom measurements. During 1994, 12 dogs were irradiated at BMRR as part of a 4 fraction dose tolerance study. The animals were first infused with BSH and irradiated daily for 4 consecutive days. BNL irradiated 2 beagles as part of their dose tolerance study using BPA fructose. In addition, a dog at WSU was irradiated at BMRR after an infusion of BPA fructose. During 1994, the INEL BNCT dosimetry team measured neutron flux and gamma dose profiles in two phantoms exposed to the epithermal neutron beam at the BMRR. These measurements were performed as a preparatory step to the commencement of human clinical trials in progress at the BMRR.

  12. Picoradian deflection measurement with an interferometric quasi-autocollimator using weak value amplification.

    Science.gov (United States)

    Turner, Matthew D; Hagedorn, Charles A; Schlamminger, Stephan; Gundlach, Jens H

    2011-04-15

    We present an "interferometric quasi-autocollimator" that employs weak value amplification to measure angular deflections of a target mirror. The device has been designed to be insensitive to all translations of the target. We present a conceptual explanation of the amplification effect used by the device. An implementation of the device demonstrates sensitivities better than 10 picoradians per root hertz between 10 and 200 Hz.

  13. Deflection measurement system for the hybrid iii six-year-old biofidelic abdomen.

    Science.gov (United States)

    Gregory, T Stan; Howes, Meghan K; Rouhana, Stephen W; Hardy, Warren N

    2012-01-01

    Motor vehicle collisions are the leading cause of death for children ages 5 to 14. Enhancement of child occupant protection is partly dependent on the ability to accurately assess the interaction of child-size occupants with restraint systems. Booster seat design and belt fit are evaluated using child anthropomorphic test devices, such as the Hybrid III 6-year-old dummy., A biofidelic abdomen for the Hybrid III 6-year-old dummy is being developed by the Ford Motor Company to enhance the dummy’s ability to assess injury risk and further quantify submarining risk by measuring abdominal deflection. A practical measurement system for the biofidelic abdominal insert has been developed and demonstrated for three dimensional determination of abdominal deflection. Quantification of insert deflection is achieved via differential signal measurement using electrodes mounted within a conductive medium. Signal amplitude is proportional to the distance between the electrodes. A microcontroller is used to calculate distances between ventral electrodes and a dorsal electrode in three dimensions. This system has been calibrated statically, and its performance demonstrated in a series of sled tests. Deflection measurements from the instrumented abdominal insert indicate performance differences between two booster seat designs, yielding an average peak anterior to posterior displacement of the abdomen of 1.0 ± 3.4 mm and 31.2 ± 7.2 mm for the seats, respectively. Implementation of a 6-year-old abdominal insert with the ability to evaluate submarining potential will likely help safety researchers further enhance booster seat design and interaction with vehicle restraint systems , and help to further understand child occupant injury risk in automobile collisions.

  14. Deflection and Supporting Force Analysis of a Slender Beam under Combined Transverse and Tensile Axial Loads

    Science.gov (United States)

    2016-05-01

    facility. The static pressure pipe was modelled as a slender propped cantilever beam (fixed at one end and roller-supported at the other) that is...Technology Group Transonic Wind Tunnel test facility. The static pressure pipe analysed herein was modelled as a slender propped cantilever beam...25 APPENDIX B: VBA FUNCTIONS FOR STATIC SOLUTION OF PROPPED CANTILEVER BEAM SUBJECTED TO COMBINED TRANSVERSE AND AXIAL LOADING

  15. An analytical model for shape memory alloy fiber-reinforced composite thin-walled beam undergoing large deflection

    Directory of Open Access Journals (Sweden)

    Yongsheng Ren

    2015-03-01

    Full Text Available The structural model of the thin-walled laminated beams with integral shape memory alloy active fibers and accounting for geometrically nonlinear is presented in this article. The structural modeling is split into two parts: a two-dimensional analysis over the cross section and a geometrically nonlinear analysis of a beam along the beam span. The variational asymptotic method is used to formulate the force–deformation relationship equations taking into account the presence of active shape memory alloy fibers distributed along the cross section of the beam. The geometrically nonlinear governing equations are derived using variational principle and based on the von Kármán-type nonlinear strain–displacement relations. The equations are then solved using Galerkin’s method and an incremental Newton–Raphson method. The validation for the proposed model has been carried out by comparison of the present results with those available in the literature. The results show that significant extension, bending, and twisting coupled nonlinear deflections occur during the phase transformation due to shape memory alloy actuation. The effects of the volume fraction of the shape memory alloy fiber and ply angle are also addressed.

  16. Geometric formula for prism deflection

    Indian Academy of Sciences (India)

    Apoorva G Wagh; Veer Chand Rakhecha

    2004-08-01

    While studying neutron deflections produced by a magnetic prism, we have stumbled upon a simple `geometric' formula. For a prism of refractive index close to unity, the deflection simply equals the product of the refractive power − 1 and the base-to-height ratio of the prism, regardless of the apex angle. The base and height of the prism are measured respectively along and perpendicular to the direction of beam propagation within the prism. The geometric formula greatly simplifies the optimisation of prism parameters to suit any specific experiment.

  17. Plasma Beam Measurements

    Science.gov (United States)

    1991-08-01

    GUN PLASMA BEAM / ,I 21 cm diameter = 0 GLASS DRIFT TUBE 50 cm diameter MCP CAMERA CLASS CROSSES (a) Gun muzzle /"- PLASA BEAM / TAROT z = 10 m MCP...discusses some of the hydrodynamic issues related to the calcula- tions. The reader may well wonder why hydrodynamics should be an issue in a 116 WL-TR-90...answer is yes for the slow beam cases and no for the fast beam cases. This is explained further. 118 WL-TR-90-83 The reader will recall the

  18. Slice emittance measurement for photocathode RF gun with solenoid scanning and RF deflecting cavity

    Science.gov (United States)

    Li, Chen; Huang, WenHui; Du, YingChao; Yan, LiXin; Tang, ChuanXiang

    2011-12-01

    The radiation of high-gain short-wavelength free-electron laser depends on the slice transverse emittance of the electron bunch. This essay introduces the method of slice emittance measurement, and shows the brief setup of this experiment using the solenoid scanning and RF deflecting cavity at Tsinghua University. The preliminary experimental results show that the slice rms emittance of the electron bunch generated by photocathode RF gun has considerable variations along the bunch and is typically less than 0.55 mm mrad for the laser rms radius of 0.4 mm.

  19. Slice emittance measurement for photocathode RF gun with solenoid scanning and RF deflecting cavity

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    The radiation of high-gain short-wavelength free-electron laser depends on the slice transverse emittance of the electron bunch. This essay introduces the method of slice emittance measurement, and shows the brief setup of this experiment using the solenoid scanning and RF deflecting cavity at Tsinghua University. The preliminary experimental results show that the slice rms emittance of the electron bunch generated by photocathode RF gun has considerable variations along the bunch and is typically less than 0.55 mm mrad for the laser rms radius of 0.4 mm.

  20. Beam emittance measurements at Fermilab

    Energy Technology Data Exchange (ETDEWEB)

    Wendt, Manfred; Eddy, Nathan; Hu, Martin; Scarpine, Victor; Syphers, Mike; Tassotto, Gianni; Thurman-Keup, Randy; Yang, Ming-Jen; Zagel, James; /Fermilab

    2008-01-01

    We give short overview of various beam emittance measurement methods, currently applied at different machine locations for the Run II collider physics program at Fermilab. All these methods are based on beam profile measurements, and we give some examples of the related instrumentation techniques. At the end we introduce a multi-megawatt proton source project, currently under investigation at Fermilab, with respect to the beam instrumentation challenges.

  1. LARGE DEFLECTION ANALYSIS OF A SATURATED POROELASTIC TIMOSHENKO BEAM%饱和多孔弹性Timoshenko梁的大挠度分析

    Institute of Scientific and Technical Information of China (English)

    杨骁; 吕新华

    2012-01-01

    基于微观不可压饱和多孔介质理论和弹性梁的大挠度变形假设,考虑梁剪切变形效应,在梁轴线不可伸长和孔隙流体仅沿轴向扩散的限定下,建立了饱和多孔弹性Timoshenko梁大挠度弯曲变形的非线性数学模型.在此基础上,利用Galerkin截断法,研究了两端可渗透简支饱和多孔Timoshenko梁在突加均布横向载荷作用下的拟静态弯曲,给出了饱和多孔 Timoshenko梁弯曲变形时固相挠度、弯矩和孔隙流体压力等效力偶等随时间的响应.比较了饱和多孔Timoshenko梁非线性大挠度和线性小挠度理论以及饱和多孔 Euler-Bernoulli梁非线性大挠度理论的结果,揭示了他们间的差异,指出当无量纲载荷参数q>l0时,应采用饱和多孔Timoshenko梁或Euler-Bernoulli梁的大挠度数学模型进行分析,特别的,当梁长细比λ<30时,应采用饱和多孔Timoshenko梁大挠度数学模型进行分析.%Based on the theory of microscopic incompressible saturated porous media and the hypothesis of large deflection deformation of the elastic beam, with the effect of shear deformation of the beam, a nonlinear mathematical model is presented for large deflection bending of saturated poroelastic Timoshenko beams under constraints of the inextensibility of the axial line and the diffusion of the pore fluid only in the axial direction of beams. Then,the nonlinear quasi-static bending of a simply supported saturated poroelastic Timoshenko beam with two ends permeable,subjected to a uniform transverse step load.is investigated with the Galerkin truncation method. The curves of deflections,bending moments of the beam skeleton and the equivalent couples of the pore fluid pressure are given. The results of the nonlinear large deflection and the linear small deflection theories of the saturated poroelastic Timoshenko beam as well as the nonlinear large deflection theory of the saturated poroelastic Euler-Bernoulli beam are compared,and the

  2. Component mode synthesis and large deflection vibration of complex structures. Volume 2: Single-mode large deflection vibrations of beams and plates using finite element method

    Science.gov (United States)

    Mei, Chuh

    1987-01-01

    A finite element method is presented for the large amplitude vibrations of complex structures that can be modelled with beam and rectangular plate elements subjected to harmonic excitation. Both inplane deformation and inertia are considered in the formulation. Derivation of the harmonic force and nonlinear stiffness matrices for a beam and a rectangular plate element are presented. Solution procedures and convergence characteristics of the finite element method are described. Nonlinear response to uniform and concentrated harmonic loadings and improved nonlinear free vibration results are presented for beams and rectangular plates of various boundary conditions.

  3. Study on the causes and methods of influencing concrete deflection

    Science.gov (United States)

    Zhou, Ying; Zhou, Xiang; Tang, Jinyu

    2017-09-01

    Under the long-term effect of static load on reinforced concrete beam, the stiffness decreases and the deformation increases with time. Therefore, the calculation of deflection is more complicated. According to the domestic and foreign research results by experiment the flexural deflection of reinforced concrete, creep, age, the thickness of the protective layer, the relative slip, the combination of steel yielding factors of reinforced concrete deflection are summarized, analyzed the advantages and disadvantages of the traditional direct measurement of deflection, that by increasing the beam height, increasing the moment of inertia, ncrease prestressed reinforcement ratio, arching, reduce the load, and other measures to reduce the deflection of prestressed construction, improve the reliability of structure.

  4. RF Phase Scan for Beam Energy Measurement of KOMAC DTL

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hansung; Kwon, Hyeokjung; Kim, Seonggu; Lee, Seokgeun; Cho, Yongsub [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    The energy gain through the drift tube linac is a function of the synchronous phase, therefore, the output beam energy from DTL can be affected by the RF phase setting in low-level RF (LLRF) system. The DTL at Korea Multi-purpose Accelerator Complex (KOMAC) consists of 11 tanks and the RF phase setting in each tank should be matched for synchronous acceleration in successive tanks. That means a proper setting of RF phase in each DTL tank is critical for efficient and loss-free operation. The matching RF phase can be determined based on the output energy measurement from the DTL tank. The beam energy can be measured by several methods. For example, we can use a bending magnet to determine the beam energy because the higher momentum of beam means the less deflection angle in the fixed magnetic field. By measuring the range of proton beam through a material with known stopping power also can be utilized to determine the beam energy. We used a well-known time-of-flight method to determine the output beam energy from the DTL tank by measuring beam phase with a beam position monitor (BPM). Based on the energy measurement results, proper RF operating point could be obtained. We performed a RF phase scan to determine the output beam energy from KOMAC DTL by using a time-of-flight method and to set RF operating point precisely. The measured beam energy was compared with a beam dynamics simulation and showed a good agreement. RF phase setting is critical issue for the efficient operation of the proton accelerator, we have a plan to implement and integrate the RF phase measurement system into an accelerator control system for future need.

  5. LEDA beam diagnostics instrumentation: Beam current measurement

    Science.gov (United States)

    Barr, D.; Day, L.; Gilpatrick, J. D.; Kasemir, K.-U.; Martinez, D.; Power, J. F.; Shurter, R.; Stettler, M.

    2000-11-01

    The Low Energy Demonstration Accelerator (LEDA) facility located at Los Alamos National Laboratory (LANL) accelerates protons to an energy of 6.7 MeV and current of 100 mA operating in either a pulsed or cw mode. Two types of current measurements are used. The first is an AC or pulsed-current measurement which uses three LANL built toroids. They are placed in the beamline in such a way as to measure important transmission parameters and act as a differential current-loss machine protection system. The second system is a DC current measurement used to measure cw beam characteristics and uses toroids from Bergoz Inc. There are two of these systems, so they can also be used for transmission measurements. The AC system uses custom processing electronics whereas the DC system uses a modified Bergoz® electronics system. Both systems feature data acquisition via a series of custom TMS320C40 Digital Signal Processing (DSP) boards. Of special interest to this paper is the operation of these systems, the calibration technique, the differential current loss measurements and fast-protection processing, current droop characteristics for the AC system, and existing system noise levels. This paper will also cover the DSP system operations and their interaction with the main accelerator control system.

  6. Effect of Tensile Reinforcement Ratio on the Effective Moment of Inertia of Reinforced Lightweight Concrete Beams for Short Term Deflection Calculation

    Directory of Open Access Journals (Sweden)

    Akmaluddin

    2011-11-01

    Full Text Available This paper presents an improvement model of the effective moment of inertia to predict the short term deflection of reinforced lightweight concrete beam. The models were developed using 9 beams of reinforced pumice-lightweight concrete tested under two symmetrical-point loads. The presence of steel reinforcement in the beam was taken into consideration in the developed model. The models were verified by test carried out on other 9 beams. Those beams subjected to various-point loads and compressive strength. The results of investigation revealed that crack moment of inertia increased with the increased tensile reinforcement ratio. Thus, the reinforcement ratio significantly affects the value of effective moment of inertia of reinforced lightweight concrete beam. All the beam test results produced considerable deflection in comparison to that obtained using current Codes either ACI or SNI. The proposed model demonstrated a good agreement to the experimental results and in some cases have similar trend to that of the ACI or SNI prediction.

  7. Bandedge optical properties of MBE grown GaAsBi films measured by photoluminescence and photothermal deflection spectroscopy

    Science.gov (United States)

    Beaudoin, M.; Lewis, R. B.; Andrews, J. J.; Bahrami-Yekta, V.; Masnadi-Shirazi, M.; O'Leary, S. K.; Tiedje, T.

    2015-09-01

    The bandedge optical properties of GaAsBi films, as thick as 470 nm, with Bi content varying from 0.7% Bi to 2.8% Bi grown by molecular beam epitaxy on GaAs substrates are measured by photoluminescence (PL) and photothermal deflection spectroscopy (PDS). The PDS spectra were fit with a modified Fernelius model which takes into account multiple reflections within the GaAsBi layer and GaAs substrate. Three undoped samples and two samples that are degenerately doped with silicon are studied. The undoped samples show a clear Urbach absorption edge with a composition dependent bandgap that decreases by 56 meV/% Bi and a composition independent Urbach slope parameter of 25 meV due to absorption by Bi cluster states near the valence band. The doped samples show a long absorption tail possibly due to absorption by gap states and free carriers in addition to a Burstein-Moss bandgap shift. PL of the undoped samples shows a lower energy emission peak due to defects not observed in the usually available thin samples (50 nm or less) grown under similar conditions.

  8. Blade Deflection Measurements of a Full-Scale UH-60A Rotor System

    Science.gov (United States)

    Olson, Lawrence E.; Abrego, Anita; Barrows, Danny A.; Burner, Alpheus W.

    2010-01-01

    Blade deflection (BD) measurements using stereo photogrammetry have been made during the individual blade control (IBC) testing of a UH-60A 4-bladed rotor system in the 40 by 80-foot test section of the National Full-Scale Aerodynamic Complex (NFAC). Measurements were made in quadrants one and two, encompassing advance ratios from 0.15 to 0.40, thrust coefficient/solidities from 0.05 to 0.12 and rotor-system drive shaft angles from 0.0 to -9.6 deg. The experiment represents a significant step toward providing benchmark databases to be utilized by theoreticians in the development and validation of rotorcraft prediction techniques. In addition to describing the stereo measurement technique and reporting on preliminary measurements made to date, the intent of this paper is to encourage feedback from the rotorcraft community concerning continued analysis of acquired data and to solicit suggestions for improved test technique and areas of emphasis for measurements in the upcoming UH-60A Airloads test at the NFAC.

  9. Large deflections of non-prismatic nonlinearly elastic cantilever beams subjected to non-uniform continuous load and a concentrated load at the free end

    Institute of Scientific and Technical Information of China (English)

    Miha Brojan; Matjaz Cebron; Franc Kosel

    2012-01-01

    This work studies large deflections of slender,non-prismatic cantilever beams subjected to a combined loading which consists of a non-uniformly distributed continuous load and a concentrated load at the free end of the beam.The material of the cantilever is assumed to be nonlinearly elastic.Different nonlinear relations between stress and strain in tensile and compressive domain are considered.The accuracy of numerical solutions is evaluated by comparing them with results from previous studies and with a laboratory experiment.

  10. Measuring Starlight Deflection during the 2017 Eclipse: Repeating the Experiment that made Einstein Famous

    Science.gov (United States)

    Bruns, Donald

    2016-05-01

    In 1919, astronomers performed an experiment during a solar eclipse, attempting to measure the deflection of stars near the sun, in order to verify Einstein's theory of general relativity. The experiment was very difficult and the results were marginal, but the success made Albert Einstein famous around the world. Astronomers last repeated the experiment in 1973, achieving an error of 11%. In 2017, using amateur equipment and modern technology, I plan to repeat the experiment and achieve a 1% error. The best available star catalog will be used for star positions. Corrections for optical distortion and atmospheric refraction are better than 0.01 arcsec. During totality, I expect 7 or 8 measurable stars down to magnitude 9.5, based on analysis of previous eclipse measurements taken by amateurs. Reference images, taken near the sun during totality, will be used for precise calibration. Preliminary test runs performed during twilight in April 2016 and April 2017 can accurately simulate the sky conditions during totality, providing an accurate estimate of the final uncertainty.

  11. The Deflection Plate Analyzer: A Technique for Space Plasma Measurements Under Highly Disturbed Conditions

    Science.gov (United States)

    Wright, Kenneth H., Jr.; Dutton, Ken; Martinez, Nelson; Smith, Dennis; Stone, Nobie H.

    2004-01-01

    A technique has been developed to measure the characteristics of space plasmas under highly disturbed conditions; e.g., non-Maxwellian plasmas with strong drifting populations and plasmas contaminated by spacecraft outgassing. The present method is an extension of the capabilities of the Differential Ion Flux Probe (DIFP) to include a mass measurement that does not include either high voltage or contamination sensitive devices such as channeltron electron multipliers or microchannel plates. This reduces the complexity and expense of instrument fabrication, testing, and integration of flight hardware as compared to classical mass analyzers. The new instrument design is called the Deflection Plate Analyzer (DPA) and can deconvolve multiple ion streams and analyze each stream for ion flux intensity (density), velocity (including direction of motion), mass, and temperature (or energy distribution). The basic functionality of the DPA is discussed. The performance characteristics of a flight instrument as built for an electrodynamic tether mission, the Propulsive Small Expendable Deployer System (ProSEDS), and the instrument s role in measuring key experimental conditions are also discussed.

  12. Beam instability induced by rf deflectors in the combiner ring of the CLIC test facility and mitigation by damped deflecting structures

    CERN Document Server

    Alesini, D; Biscari, C; Ghigo, A; Corsini, R

    2011-01-01

    In the CTF3 (CLIC test facility 3) run of November 2007, a vertical beam instability has been found in the combiner ring during operation. After a careful analysis, the source of the instability has been identified in the vertical deflecting modes trapped in the rf deflectors and excited by the beam passage. A dedicated tracking code that includes the induced transverse wakefield and the multibunch multipassage effects has been written and the results of the beam dynamics analysis are presented in the paper. The mechanism of the instability was similar to the beam breakup in a linear accelerator or in an energy recovery linac. The results of the code allowed identifying the main key parameters driving such instability and allowed finding the main knobs to mitigate it. To completely suppress such beam instability, two new rf deflectors have been designed, constructed, and installed in the ring. In the new structures the frequency separation between the vertical and horizontal deflecting modes has been increase...

  13. Measurement Error Effects of Beam Parameters Determined by Beam Profiles

    CERN Document Server

    Jang, Ji-Ho; Jeon, Dong-O

    2015-01-01

    A conventional method to determine beam parameters is using the profile measurements and converting them into the values of twiss parameters and beam emittance at a specified position. The beam information can be used to improve transverse beam matching between two different beam lines or accelerating structures. This work is related with the measurement error effects of the beam parameters and the optimal number of profile monitors in a section between MEBT (medium energy beam transport) and QWR (quarter wave resonator) of RAON linear accelerator.

  14. Wire Scanner Beam Profile Measurements: LANSCE Facility Beam Development

    Energy Technology Data Exchange (ETDEWEB)

    Gilpatrick, John D. [Los Alamos National Laboratory; Batygin, Yuri K. [Los Alamos National Laboratory; Gonzales, Fermin [Los Alamos National Laboratory; Gruchalla, Michael E. [Los Alamos National Laboratory; Kutac, Vincent G. [Los Alamos National Laboratory; Martinez, Derwin [Los Alamos National Laboratory; Sedillo, James Daniel [Los Alamos National Laboratory; Pillai, Chandra [Los Alamos National Laboratory; Rodriguez Esparza, Sergio [Los Alamos National Laboratory; Smith, Brian G. [Los Alamos National Laboratory

    2012-05-15

    The Los Alamos Neutron Science Center (LANSCE) is replacing Wire Scanner (WS) beam profile measurement systems. Three beam development tests have taken place to test the new wire scanners under beam conditions. These beam development tests have integrated the WS actuator, cable plant, electronics processors and associated software and have used H{sup -} beams of different beam energy and current conditions. In addition, the WS measurement-system beam tests verified actuator control systems for minimum profile bin repeatability and speed, checked for actuator backlash and positional stability, tested the replacement of simple broadband potentiometers with narrow band resolvers, and tested resolver use with National Instruments Compact Reconfigurable Input and Output (cRIO) Virtual Instrumentation. These beam tests also have verified how trans-impedance amplifiers react with various types of beam line background noise and how noise currents were not generated. This paper will describe these beam development tests and show some resulting data.

  15. Lifetime measurement of excited atomic and ionic states of some noble gases using the high-frequency deflection technique

    Indian Academy of Sciences (India)

    M B Das; S Karmakar

    2005-12-01

    High-frequency deflection (HFD) technique with a delayed coincidence single photon counting arrangement is an efficient technique for radiative lifetime measurement. An apparatus for measurement of the radiative lifetime of atoms and molecules has been developed in our laboratory and measurements have been performed with great success in a large number of atoms and ions. The present version of the apparatus is described in this paper together with a brief description of the basic features and performance.

  16. Deflection of high-intensity pulsed ion beam in focusing magnetically insulated ion diode with a passive anode

    Science.gov (United States)

    Zhu, X. P.; Zhang, Q.; Ding, L.; Zhang, Z. C.; Yu, N.; Pushkarev, A.; Lei, M. K.

    2016-12-01

    The focused high-intensity pulsed ion beam (HIPIB) of 100 ns order pulse is generated with respect to its spatial stability in two types of magnetically insulated ion diodes (MIDs) with geometrical focusing configuration using the passive anode, i.e., insulation of electrons with an external magnetic-field and a self-magnetic field, respectively. Anode plasma formation for the ion beam generation is based on different processes in the two types of MIDs, as the surface breakdown on the polymer-coated anode operated in the unipolar pulse mode for the external-magnetic field MID and the explosive electron emission on the graphite anode in the bipolar-pulse mode for the self-magnetic field MID. Typical energy density per pulse is in the range of 3-6 J/cm2, at an accelerating voltage of 200-300 kV with a pulse duration of 120-150 ns. The spatial deviations of the HIPIB is evaluated by measuring the energy density distribution by using an infrared diagnostic method considering neutralizing during the ion beam propagation to the focal plane with a spatial resolution of 1 mm. The ion beam deviation is about ±1.5 mm for the external-magnetic field MID and ±2.5 mm for the self-magnetic field MID, leading to a fluctuation in the energy density of 1%-12%, and 9%-27% within a 10 mm range at the focal point, respectively. It is revealed that the displacement of different parts of a beam spot occurs nonsynchronously, mainly attributable to the intrinsic diode processes of plasma generation and expansion, and ion beam extraction from the anode-cathode gap, while the influence of magnetic field in the transportation region is negligible. The ion beam spatial deviation has a major influence on the shot-to-shot stability of ion beam, and it is suggested that the stability can be enhanced via diode process improvement.

  17. 蜂窝梁应力和挠度计算方法%Stress and deflection calculation methods of castellated beams

    Institute of Scientific and Technical Information of China (English)

    李鹏飞; 姚谦峰

    2011-01-01

    In order to study the stress and deflection calculation methods, the stress characteristics of castellated beams were obtained through overall and local stability analysis by ANSYS.Based on the stress distribution and the structural characteristics of castellated beams, the practical formulas for stress calculation were deduced on the hypothesis of open-web truss theory.The deflection formulas were derived according to the web openings characteristics of castellated beams and the unit force method.By comparing the formula calculation results with finite element analysis results, the correctness of open-web truss theory hypothesis and precision of the formulas for stress and deflection were verified.%为了研究蜂窝梁应力和挠度的计算方法,应用有限元软件ANSYS对蜂窝梁进行了整体和局部分析,得出蜂窝梁的受力特点.结合蜂窝梁应力分布特点和自身结构特征,以空腹桁架理论为基础,对蜂窝梁力学行为进行分析,推导均布荷载作用下蜂窝梁应力的计算公式.根据蜂窝梁腹板开孔的结构特点,以单位力法为基础,推导蜂窝梁挠度的计算公式.对不同蜂窝梁进行数值分析和理论计算,将应力和挠度的公式计算结果与有限元分析结果进行对比,验证了空腹桁架计算假定的正确性以及应力和挠度计算公式的准确性.

  18. 压电复合材料梁和板的变形控制问题%Deflection Control of Laminated Beams and Plates with Piezoelectric Patches

    Institute of Scientific and Technical Information of China (English)

    程立平; 高存法; 刘磊

    2011-01-01

    由于具有良好的结构、力学性能,复合材料层合板在现代飞行器上大量应用;而压电复合材料,作为一种新兴的智能材料,由于其独特的力电耦合性能得到了人们更多的关注.本文研究含有压电片的复合材料梁和板在电场作用下的变形控制问题.基于经典的梁理论和层合板理论,分别研究了下列问题:(1)双压电片布置的悬臂梁的变形;(2)含有压电层的层合板变形控制问题;(3)含有一对压电片的层合板的变形控制问题.针对上述问题,分别给出了理论解和数值解,并进行了相关讨论分析.结果表明压电材料可对结构进行精确控制,因此本文的结果可对复合材料梁和板在电场作用下的变形控制问题提供工程参考.%Laminated plates of composite materials,duo to their excellent structure and mechanics properties, have found wide application in modern aircrafts. Especially, piezoelectric composites, as a new kind of smart materials with good properties of electro-mechanical coupling, have been received more interests in engineering. The deflection control of laminated composite beams and plates was studied with piezoelectric patches under electric field. Based on the classical theories of beam and plate, the present work deals with the following problems: (1) the deflection control of a cantilever beam with one pair of piezoelectric patches, (2) the deflection control of piezoelectric laminated plates,and (3) the deflection control of laminated plates with one pair of piezoelectric patches. For the above cases, the theoretical results and numerical examples were presented, respectively,and the related discussions were also given. It shows that the piezoelectric material can be used in precise control of structures and thus the outcome in the present work can be useful to the problems of shape control for laminated beams and plates under electric field.

  19. FEM Calculation of Space Timoshenko Beam of Large Deflection%空间大挠度Timoshenko梁的有限元计算方法

    Institute of Scientific and Technical Information of China (English)

    刘小会; 王家林; 严波

    2013-01-01

    A variation principle for Timoshenko beams of large deflection with geometrical non-linearity is presented.And the space beam element stiffness matrix of large deflection can be deduced from this variation principle,considering the effect of the shear deformation.To improve the computational precision and efficiency for the large displacement and rotation of beam,a finite element method based on the moment-curvature relationship of beam section is presented.The method calculated by node coordinates of the beam element is applied to calculate the internal nodal forces.A nonlinear finite element code is then developed which considers the effects of large rotations,large displacements and shear deformations.Numerical examples are provided in order to verify the feasibility and effectivity of the presented method.%解析了几何非线性的大挠度Timoshenko梁的变分原理,建立了考虑横向剪切应变的大挠度梁的空间单元刚度矩阵;采用基于梁截面弯矩-曲率关系的宏观有限元方法,直接通过节点坐标系计算内部节点力,提高了大位移、大转动梁的计算精度及效率;编制了考虑单元大转角、大位移和剪切变形影响的非线性有限元程序;通过数值算例验证了该程序的可行性和有效性.

  20. Real-Time Deflection Monitoring for Milling of a Thin-Walled Workpiece by Using PVDF Thin-Film Sensors with a Cantilevered Beam as a Case Study

    National Research Council Canada - National Science Library

    Luo, Ming; Liu, Dongsheng; Luo, Huan

    2016-01-01

    .... To understand the workpiece deflection behavior in a machining process, a new real-time nonintrusive method for deflection monitoring is presented, and a detailed analysis of workpiece deflection...

  1. Novel Method of Measuring Cantilever Deflection during an AFM Force Measurement

    Science.gov (United States)

    Hlady, V.; Pierce, M.; Pungor, A.

    2012-01-01

    A combination of a reflection interference contrast microscope (RICM) and the atomic force microscope (AFM) was used to monitor the cantilever–surface separation distance during force measurements using the streptavidin–biotin recognition pairs. The RICM showed that the cantilever loses contact with the surface before the final rupture of the adhesive bonds is measured by the AFM detection system. This finding suggests that the immobilization of biotin by physisorbed albumin and subsequent binding of streptavidin might have created a cross-linked protein network whose cohesion is tested by the AFM cantilever with the immobilized biotin ligands. PMID:25132721

  2. A transverse emittance and acceptance measurement system in a low-energy beam transport line

    Energy Technology Data Exchange (ETDEWEB)

    Kashiwagi, H., E-mail: kashiwagi.hirotsugu@jaea.go.jp; Miyawaki, N.; Kurashima, S.; Okumura, S. [Department of Advanced Radiation Technology, Japan Atomic Energy Agency, 1233 Watanuki, Takasaki, Gunma 370-1292 (Japan)

    2014-02-15

    A transverse beam emittance and acceptance measurement system has been developed to visualize the relationship between the injected beam emittance and the acceptance of a cyclotron. The system is composed of a steering magnet, two pairs of slits to limit the horizontal and vertical phase-space, a beam intensity detector just behind the slits for the emittance measurement, and a beam intensity detector in the cyclotron for the acceptance measurement. The emittance is obtained by scanning the slits and measuring the beam intensity distribution. The acceptance is obtained by measuring the distribution of relative beam transmission by injecting small emittance beams at various positions in a transverse phase-space using the slits. In the acceptance measurement, the beam from an ion source is deflected to the defined region by the slits using the steering magnet so that measurable acceptance area covers a region outside the injection beam emittance. Measurement tests were carried out under the condition of accelerating a beam of {sup 16}O{sup 6+} from 50.2 keV to 160 MeV. The emittance of the injected beam and the acceptance for accelerating and transporting the beam to the entrance of the extraction deflector were successfully measured. The relationship between the emittance and acceptance is visualized by displaying the results in the same phase-plane.

  3. LHC Beam Instrumentation: Beam Profile Measurements (2/3)

    CERN Document Server

    CERN. Geneva

    2014-01-01

    The LHC is equipped with a full suite of sophisticated beam instrumentation which has been essential for rapid commissioning, the safe increase in total stored beam power and the understanding of machine optics and accelerator physics phenomena. These lectures will introduce these systems and comment on their contributions to the various stages of beam operation. They will include details on: the beam position system and its use for real-time global orbit feedback; the beam loss system and its role in machine protection; total and bunch by bunch intensity measurements; tune measurement and feedback; diagnostics for transverse beam size measurements, abort gap monitoring and longitudinal density measurements. Issues and problems encountered along the way will also be discussed together with the prospect for future upgrades.

  4. Prediction and compensation of magnetic beam deflection in MR-integrated proton therapy: a method optimized regarding accuracy, versatility and speed

    Science.gov (United States)

    Schellhammer, Sonja M.; Hoffmann, Aswin L.

    2017-02-01

    The integration of magnetic resonance imaging (MRI) and proton therapy for on-line image-guidance is expected to reduce dose delivery uncertainties during treatment. Yet, the proton beam experiences a Lorentz force induced deflection inside the magnetic field of the MRI scanner, and several methods have been proposed to quantify this effect. We analyze their structural differences and compare results of both analytical and Monte Carlo models. We find that existing analytical models are limited in accuracy and applicability due to critical approximations, especially including the assumption of a uniform magnetic field. As Monte Carlo simulations are too time-consuming for routine treatment planning and on-line plan adaption, we introduce a new method to quantify and correct for the beam deflection, which is optimized regarding accuracy, versatility and speed. We use it to predict the trajectory of a mono-energetic proton beam of energy E 0 traversing a water phantom behind an air gap within an omnipresent uniform transverse magnetic flux density B 0. The magnetic field induced dislocation of the Bragg peak is calculated as function of E 0 and B 0 and compared to results obtained with existing analytical and Monte Carlo methods. The deviation from the Bragg peak position predicted by Monte Carlo simulations is smaller for the new model than for the analytical models by up to 2 cm. The model is faster than Monte Carlo methods, less assumptive than the analytical models and applicable to realistic magnetic fields. To compensate for the predicted Bragg peak dislocation, a numerical optimization strategy is introduced and evaluated. It includes an adjustment of both the proton beam entrance angle and energy of up to 25° and 5 MeV, depending on E 0 and B 0. This strategy is shown to effectively reposition the Bragg peak to its intended location in the presence of a magnetic field.

  5. Prediction and compensation of magnetic beam deflection in MR-integrated proton therapy: a method optimized regarding accuracy, versatility and speed.

    Science.gov (United States)

    Schellhammer, Sonja M; Hoffmann, Aswin L

    2017-02-21

    The integration of magnetic resonance imaging (MRI) and proton therapy for on-line image-guidance is expected to reduce dose delivery uncertainties during treatment. Yet, the proton beam experiences a Lorentz force induced deflection inside the magnetic field of the MRI scanner, and several methods have been proposed to quantify this effect. We analyze their structural differences and compare results of both analytical and Monte Carlo models. We find that existing analytical models are limited in accuracy and applicability due to critical approximations, especially including the assumption of a uniform magnetic field. As Monte Carlo simulations are too time-consuming for routine treatment planning and on-line plan adaption, we introduce a new method to quantify and correct for the beam deflection, which is optimized regarding accuracy, versatility and speed. We use it to predict the trajectory of a mono-energetic proton beam of energy E 0 traversing a water phantom behind an air gap within an omnipresent uniform transverse magnetic flux density B 0. The magnetic field induced dislocation of the Bragg peak is calculated as function of E 0 and B 0 and compared to results obtained with existing analytical and Monte Carlo methods. The deviation from the Bragg peak position predicted by Monte Carlo simulations is smaller for the new model than for the analytical models by up to 2 cm. The model is faster than Monte Carlo methods, less assumptive than the analytical models and applicable to realistic magnetic fields. To compensate for the predicted Bragg peak dislocation, a numerical optimization strategy is introduced and evaluated. It includes an adjustment of both the proton beam entrance angle and energy of up to 25° and 5 MeV, depending on E 0 and B 0. This strategy is shown to effectively reposition the Bragg peak to its intended location in the presence of a magnetic field.

  6. Beam energy online measurement of BEPCII LINAC

    CERN Document Server

    Wang, Shao-Zhe; Chi, Yun-Long

    2015-01-01

    This paper describes beam energy online measurement of BEPCII linac, presents the calculation formula and some of the results. The method mentioned here measures the beam energy by acquiring beam positions in the horizontal direction with three beam position monitors (BPM) eliminating the effect of orbit fluctuation, which is much better than the one using the single BPM. The error analysis indicates that this online measurement has further potential usage such as a part of beam energy feedback system. The reliability of this method is also discussed and demonstrated in the end of this paper.

  7. SPEAKING IN LIGHT - Jupiter radio signals as deflections of light-emitting electron beams in a vacuum chamber

    Science.gov (United States)

    Petrovic, K.

    2015-10-01

    Light emitting electron beam generated in a vacuum chamber is used as a medium for visualizing Jupiter's electromagnetic radiation. Dual dipole array antenna is receiving HF radio signals that are next amplified to radiate a strong electromagnetic field capable of influencing the propagation of electron beam in plasma. Installation aims to provide a platform for observing the characteristics of light emitting beam in 3D, as opposed to the experiments with cathode ray tubes in 2-dimensional television screens. Gas giant 'speaking' to us by radio waves bends the light in the tube, allowing us to see and hear the messages of Jupiter - God of light and sky.

  8. Sensitive beam current measurement for FAIR

    Energy Technology Data Exchange (ETDEWEB)

    Schwickert, Marcus; Kurian, Febin; Reeg, Hansjoerg [GSI Helmholtzzentrum fuer Schwerionenforschung GmbH, Darmstadt (Germany); Seidel, Paul; Neubert, Ralf [Friedrich-Schiller-Universitaet Jena (Germany); Geithner, Rene; Vodel, Wolfgang [Helmholtz-Institut Jena (Germany)

    2012-07-01

    Presently FAIR, the Facility for Antiproton and Ion Research, entered the final planning phase at GSI. The new accelerator facility requires precise devices for beam current measurements due to the large dynamics in beam intensities for the various synchrotrons, transport lines and storage rings. We report on the actual developments of beam diagnostic devices for the measurement of beam intensities ranging from 5 x 10{sup 11} uranium ions down to the detection of less than 10{sup 4} antiprotons. This contribution gives an overview of the planned instruments with a focus on non-intercepting beam current transformers, and summarizes the on-going development of a cryogenic current comparator.

  9. Quantitative measurements of electromechanical response with a combined optical beam and interferometric atomic force microscope

    Energy Technology Data Exchange (ETDEWEB)

    Labuda, Aleksander; Proksch, Roger [Asylum Research an Oxford Instruments Company, Santa Barbara, California 93117 (United States)

    2015-06-22

    An ongoing challenge in atomic force microscope (AFM) experiments is the quantitative measurement of cantilever motion. The vast majority of AFMs use the optical beam deflection (OBD) method to infer the deflection of the cantilever. The OBD method is easy to implement, has impressive noise performance, and tends to be mechanically robust. However, it represents an indirect measurement of the cantilever displacement, since it is fundamentally an angular rather than a displacement measurement. Here, we demonstrate a metrological AFM that combines an OBD sensor with a laser Doppler vibrometer (LDV) to enable accurate measurements of the cantilever velocity and displacement. The OBD/LDV AFM allows a host of quantitative measurements to be performed, including in-situ measurements of cantilever oscillation modes in piezoresponse force microscopy. As an example application, we demonstrate how this instrument can be used for accurate quantification of piezoelectric sensitivity—a longstanding goal in the electromechanical community.

  10. Two-mode polarized traveling wave deflecting structure

    Institute of Scientific and Technical Information of China (English)

    谭建豪; 顾强; 方文程; 童德春; 赵振堂

    2015-01-01

    In this paper, we propose a two-mode polarizable deflecting structure, as a new concept for bunch measure-ment and beam control. With two modes of HEM11 and HEM12 operating in the same structure on horizontal and vertical directions, respectively, the operation status can be switched between the two polarization modes. They can be operated simultaneously with two independent input power sources. With two-mode deflecting structure, the bunch distortion caused by the geometric wake-fields in the accelerating structure can be mea-sured by one structure.

  11. Free vibration analysis of pre-stressed FGM Timoshenko beams under large transverse deflection by a variational method

    Directory of Open Access Journals (Sweden)

    Amlan Paul

    2016-06-01

    Full Text Available A theoretical study on free vibration behavior of pre-stressed functionally graded material (FGM beam is carried out. Power law variation of volume fraction along the thickness direction is considered. Geometric non-linearity is incorporated through von Kármán non-linear strain–displacement relationship. The governing equation for the static problem is obtained using minimum potential energy principle. The dynamic problem for the pre-stressed beam is formulated as an eigenvalue problem using Hamilton's principle. Three classical boundary conditions with immovable ends are considered for the present work, namely clamped–clamped, simply supported–simply supported and clamped–simply supported. Four different FGM beams, namely Stainless Steel–Silicon Nitride, Stainless Steel–Zirconia, Stainless Steel–Alumina and Titanium alloy–Zirconia, are considered for generation of results. Numerical results for non-dimensional frequency parameters of undeformed beam are presented. The results are presented in non-dimensional pressure-displacement plane for the static problem and in non-dimensional frequency-displacement plane for the dynamic problem. Comparative frequency-displacement plots are presented for different FGMs and also for different volume fraction indices.

  12. The differential equations defining deflection of particles of ion beam from axial trajectory in electric and magnetic fields

    Energy Technology Data Exchange (ETDEWEB)

    Baisanov, O.A. [Military Institute of Air Defense Forces, Aktobe (Kazakhstan); Doskeyev, G.A.; Doskeyev, T.G. [Aktobe State University named after K. Zhubanov, Aktobe (Kazakhstan); Spivak-Lavrov, I.F., E-mail: spivakif@rambler.ru [Aktobe State University named after K. Zhubanov, Aktobe (Kazakhstan)

    2011-07-21

    The exact differential equations defining deviations of the paths of charged particles from the axial trajectory are derived in curvilinear coordinates. These equations are in a form suited for carrying out relativistically correct numerical calculations of the dynamics of charged particle beams.

  13. Beam based measurement of beam position monitor electrode gains

    Directory of Open Access Journals (Sweden)

    D. L. Rubin

    2010-09-01

    Full Text Available Low emittance tuning at the Cornell Electron Storage Ring (CESR test accelerator depends on precision measurement of vertical dispersion and transverse coupling. The CESR beam position monitors (BPMs consist of four button electrodes, instrumented with electronics that allow acquisition of turn-by-turn data. The response to the beam will vary among the four electrodes due to differences in electronic gain and/or misalignment. This variation in the response of the BPM electrodes will couple real horizontal offset to apparent vertical position, and introduce spurious measurements of coupling and vertical dispersion. To alleviate this systematic effect, a beam based technique to measure the relative response of the four electrodes has been developed. With typical CESR parameters, simulations show that turn-by-turn BPM data can be used to determine electrode gains to within ∼0.1%.

  14. A device for measuring electron beam characteristics

    Directory of Open Access Journals (Sweden)

    M. Andreev

    2017-01-01

    Full Text Available This paper presents a device intended for diagnostics of electron beams and the results obtained with this device. The device comprises a rotating double probe operating in conjunction with an automated probe signal collection and processing system. This provides for measuring and estimating the electron beam characteristics such as radius, current density, power density, convergence angle, and brightness.

  15. The Deflection Question

    Science.gov (United States)

    Greenberg, A. H.; Nesvold, E.; van Heerden, E.; Erasmus, N.; Marchis, F.

    2016-12-01

    On 15 February, 2013, a 15 m diameter asteroid entered the Earth's atmosphere over Russia. The resulting shockwave injured nearly 1500 people, and incurred 33 million (USD) in infrastructure damages. The Chelyabinsk meteor served as a forceful demonstration of the threat posed to Earth by the hundreds of potentially hazardous objects (PHOs) that pass near the Earth every year. Although no objects have yet been discovered on an impact course for Earth, an impact is virtually statistically guaranteed at some point in the future. While many impactor deflection technologies have been proposed, humanity has yet to demonstrate the ability to divert an impactor when one is found. Developing and testing any single proposed technology will require significant research time and funding. This leaves open an obvious question - towards which technologies should funding and research be directed, in order to maximize our preparedness for when an impactor is eventually found? To help answer this question, we have created a detailed framework for analyzing various deflection technologies and their effectiveness. Using an n-body integrator (REBOUND), we have simulated the attempted deflections of a population of Earth-impacting objects with a variety of velocity perturbations (∂Vs), and measured the effects that these perturbations had on impact probability. We then mapped the ∂Vs applied in the orbital simulations to the technologies capable of achieving those perturbations, and analyzed which set of technologies would be most effective at preventing a PHO from impacting the earth. As a final step, we used the results of these simulations to train a machine learning algorithm. This algorithm, combined with a simulated PHO population, can predict which technologies are most likely to be needed. The algorithm can also reveal which impactor observables (mass, spin, orbit, etc.) have the greatest effect on the choice of deflection technology. These results can be used as a tool to

  16. Overview of LHC Beam Loss Measurements

    CERN Document Server

    Dehning, B; Effinger, E; Emery, J; Fadakis, E; Holzer, E B; Jackson, S; Kruk, G; Kurfuerst, C; Marsili, A; Misiowiec, M; Nebot Del Busto, E; Nordt, A; Priebe, A; Roderick, C; Sapinski, M; Zamantzas, C; Grishin, V; Griesmayer, E

    2011-01-01

    The LHC beam loss monitoring system provides measurements with an update rate of 1 Hz and high time resolution data by event triggering. These informations are used for the initiation of beam aborts, fixed displays and the off line analysis. The analysis of fast and localized loss events resulted in the determination of its rate, duration, peak amplitudes, its scaling with intensity, number of bunches and beam energy. The calibration of the secondary shower beam loss signal in respect to the needed beam energy deposition to quench the magnet coil is addressed at 450GeV and 3.5T eV . The adjustment of collimators is checked my measuring the loss pattern and its variation in the collimation regions of the LHC. Loss pattern changes during a fill allow the observation of non typical fill parameters.

  17. Real-Time Deflection Monitoring for Milling of a Thin-Walled Workpiece by Using PVDF Thin-Film Sensors with a Cantilevered Beam as a Case Study

    Directory of Open Access Journals (Sweden)

    Ming Luo

    2016-09-01

    Full Text Available Thin-walled workpieces, such as aero-engine blisks and casings, are usually made of hard-to-cut materials. The wall thickness is very small and it is easy to deflect during milling process under dynamic cutting forces, leading to inaccurate workpiece dimensions and poor surface integrity. To understand the workpiece deflection behavior in a machining process, a new real-time nonintrusive method for deflection monitoring is presented, and a detailed analysis of workpiece deflection for different machining stages of the whole machining process is discussed. The thin-film polyvinylidene fluoride (PVDF sensor is attached to the non-machining surface of the workpiece to copy the deflection excited by the dynamic cutting force. The relationship between the input deflection and the output voltage of the monitoring system is calibrated by testing. Monitored workpiece deflection results show that the workpiece experiences obvious vibration during the cutter entering the workpiece stage, and vibration during the machining process can be easily tracked by monitoring the deflection of the workpiece. During the cutter exiting the workpiece stage, the workpiece experiences forced vibration firstly, and free vibration exists until the amplitude reduces to zero after the cutter exits the workpiece. Machining results confirmed the suitability of the deflection monitoring system for machining thin-walled workpieces with the application of PVDF sensors.

  18. Real-Time Deflection Monitoring for Milling of a Thin-Walled Workpiece by Using PVDF Thin-Film Sensors with a Cantilevered Beam as a Case Study.

    Science.gov (United States)

    Luo, Ming; Liu, Dongsheng; Luo, Huan

    2016-09-10

    Thin-walled workpieces, such as aero-engine blisks and casings, are usually made of hard-to-cut materials. The wall thickness is very small and it is easy to deflect during milling process under dynamic cutting forces, leading to inaccurate workpiece dimensions and poor surface integrity. To understand the workpiece deflection behavior in a machining process, a new real-time nonintrusive method for deflection monitoring is presented, and a detailed analysis of workpiece deflection for different machining stages of the whole machining process is discussed. The thin-film polyvinylidene fluoride (PVDF) sensor is attached to the non-machining surface of the workpiece to copy the deflection excited by the dynamic cutting force. The relationship between the input deflection and the output voltage of the monitoring system is calibrated by testing. Monitored workpiece deflection results show that the workpiece experiences obvious vibration during the cutter entering the workpiece stage, and vibration during the machining process can be easily tracked by monitoring the deflection of the workpiece. During the cutter exiting the workpiece stage, the workpiece experiences forced vibration firstly, and free vibration exists until the amplitude reduces to zero after the cutter exits the workpiece. Machining results confirmed the suitability of the deflection monitoring system for machining thin-walled workpieces with the application of PVDF sensors.

  19. Measurements of aperture and beam lifetime using movable beam scrapers in Indus-2 electron storage ring

    Science.gov (United States)

    Kumar, Pradeep; Ghodke, A. D.; Karnewar, A. K.; Holikatti, A. C.; Yadav, S.; Puntambekar, T. A.; Singh, G.; Singh, P.

    2013-12-01

    In this paper, the measurements of vertical and horizontal aperture which are available for stable beam motion in Indus-2 at beam energy 2.5 GeV using movable beam scrapers are presented. These beam scrapers are installed in one of the long straight sections in the ring. With the movement of beam scrapers towards the beam centre, the beam lifetime is measured. The beam lifetime data obtained from the movement of vertical and horizontal beam scrapers are analyzed. The contribution of beam loss due to beam-gas scattering (vacuum lifetime) and electron-electron scattering within a beam bunch (Touschek lifetime) is separated from the measured beam lifetime at different positions of the beam scrapers. Vertical and horizontal beam sizes at scrapers location are estimated from the scraper movement towards the beam centre in quantum lifetime limit and their values closely agree with measured value obtained using X-ray diagnostic beamline.

  20. Measurements of aperture and beam lifetime using movable beam scrapers in Indus-2 electron storage ring.

    Science.gov (United States)

    Kumar, Pradeep; Ghodke, A D; Karnewar, A K; Holikatti, A C; Yadav, S; Puntambekar, T A; Singh, G; Singh, P

    2013-12-01

    In this paper, the measurements of vertical and horizontal aperture which are available for stable beam motion in Indus-2 at beam energy 2.5 GeV using movable beam scrapers are presented. These beam scrapers are installed in one of the long straight sections in the ring. With the movement of beam scrapers towards the beam centre, the beam lifetime is measured. The beam lifetime data obtained from the movement of vertical and horizontal beam scrapers are analyzed. The contribution of beam loss due to beam-gas scattering (vacuum lifetime) and electron-electron scattering within a beam bunch (Touschek lifetime) is separated from the measured beam lifetime at different positions of the beam scrapers. Vertical and horizontal beam sizes at scrapers location are estimated from the scraper movement towards the beam centre in quantum lifetime limit and their values closely agree with measured value obtained using X-ray diagnostic beamline.

  1. A Comparative Study of the Applied Methods for Estimating Deflection of the Vertical in Terrestrial Geodetic Measurements

    Directory of Open Access Journals (Sweden)

    Luca Vittuari

    2016-04-01

    Full Text Available This paper compares three different methods capable of estimating the deflection of the vertical (DoV: one is based on the joint use of high precision spirit leveling and Global Navigation Satellite Systems (GNSS, a second uses astro-geodetic measurements and the third gravimetric geoid models. The working data sets refer to the geodetic International Terrestrial Reference Frame (ITRF co-location sites of Medicina (Northern, Italy and Noto (Sicily, these latter being excellent test beds for our investigations. The measurements were planned and realized to estimate the DoV with a level of precision comparable to the angular accuracy achievable in high precision network measured by modern high-end total stations. The three methods are in excellent agreement, with an operational supremacy of the astro-geodetic method, being faster and more precise than the others. The method that combines leveling and GNSS has slightly larger standard deviations; although well within the 1 arcsec level, which was assumed as threshold. Finally, the geoid model based method, whose 2.5 arcsec standard deviations exceed this threshold, is also statistically consistent with the others and should be used to determine the DoV components where local ad hoc measurements are lacking.

  2. Nuclear Astrophysics Measurements with Radioactive Beams

    Science.gov (United States)

    Smith, Michael S.; Ernst Rehm, K.

    Radioactive nuclei play an important role in a diverse range of astrophysical phenomena including the early universe, the sun, red giant stars, nova explosions, X-ray bursts, supernova explosions, and supermassive stars. Measurements of reactions with beams of short-lived radioactive nuclei can, for the first time, probe the nuclear reactions occurring in these cosmic phenomena. This article describes the astrophysical motivation for experiments with radioactive beams, the techniques to produce these beams and perform astrophysically relevant measurements, results from recent experiments, and plans for future facilities.

  3. Cross-Sectional Measuring of Optical Beam

    Directory of Open Access Journals (Sweden)

    Tomas David

    2011-01-01

    Full Text Available This article deals with problematic of measuring of optical beam in free space optics (FSO. The professional FSO link was created between two buildings standing 1,5 kilometers apart from each other. Signal passing through the atmospheric media between optical heads is affected. This happens due to effects in atmospheric media. This article describes creating of the device for measuring the intensity of optical beam in 2D space and its subsequent rendering into 3D graph.

  4. Electro-optical approach to pavement deflection management

    Science.gov (United States)

    Rish, Jeff W., III; Adcock, Avery D.; Tuan, Christopher Y.; Baker, Samuel L.; Welker, Hugh W., II; Johnson, Roger F.

    1995-07-01

    A prototype continuous deflection device, referred to as a rolling weight deflectometer (RWD), has been developed as a nondestructive evaluation tool for airfield pavements. The system consists of a rigid trailer equipped with specially designed optical triangulation pavement sensors, a high-speed data acquisition system, and a high-pressure tire/load platform assembly. Pavement sensors are mounted on a rigid box beam equipped with an internal sensor system that corrects, in real time, the relative pavement height position measurements for displacements induced in the beam by mechanical vibrations, changes in temperature, or nonuniform dynamic loads at points where the beam attaches to the frame. The device produces continuous deflection profiles that show pavement response to a moving loaded wheel along the path of travel. These deflection profiles, combined with multiple passes along a lane, provide a far more detailed picture of the pavement structural integrity than has ever before been possible, because existing evaluation tools only produce response information at discrete points. Preliminary results show deflections measured by the RWD are in general agreement with the expected pavement response for various loads. A discussion of the device configuration, preliminary data, and potential as a pavement management tool is presented.

  5. Test Beam Measurements on Picosec Gaseous Detector.

    CERN Document Server

    Sohl, Lukas

    2017-01-01

    In the Picosec project micro pattern gaseous detectors with a time resolution of some ten picoseconds are developed. The detectors are based on Micromegas detectors. With a cherenkov window and a photocathode the time jitter from different position of the primary ionization clusters can be substituted. This reports describes the beam setup and measurements of different Picosec prototypes. A time resolution of under 30 ps has been measured during the test beam. This report gives an overview of my work as a Summer Student. I set up and operated a triple-GEM tracker and a trigger system for the beam. During the beam I measured different prototypes of Picosec detectors and analysed the data.

  6. Beam emittance measurements on multicusp ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Sarstedt, M.; Lee, Y.; Leung, K.N.; Perkins, L.T.; Pickard, D.S.; Weber, M.; Williams, M.D.

    1995-08-01

    Multicusp ion sources are used for various applications. Presently, the implementation of this type of ion source is planned for the development of an ion beam lithography machine, which will be used for the projection of sub-0.2 micron patterns onto a wafer substrate. Since, for this application, a very good beam quality and a small ion energy spread are required, emittance measurements have been performed on a multicusp ion source for various source conditions. It is shown that the installation of proper capacitors between the extraction electrodes is necessary to avoid rf-pickup, which otherwise leads to a distortion of the beam emittance. The influence of the magnetic filter field on the beam emittance has been investigated, and the beam emittance of a dc filament-discharge plasma has also been compared to that of an rf-generated plasma.

  7. Beam emittance measurements on multicusp ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Sarstedt, M.; Lee, Y.; Leung, K.N. [and others

    1995-08-01

    Multicusp ion sources are used for various applications. Presently, the implementation of this type of ion source planned for the development of an ion beam lithography machine, which will be used for the projection of sub-0.2 {mu}m patterns onto a wafer substrate. Since, for this application, a very good beam quality and a small ion energy spread are required, emittance measurements have been performed on a multicusp ion source for various source conditions. It is shown that the installation of proper capacitors between the extraction electrodes is necessary to avoid rf-pickup, which otherwise leads to a distortion of the beam emittance. The influence of the magnetic filter field on the beam emittance has been investigated, and the beam emittance of a dc filament-discharge plasma has also been compared to that of an rf-generated plasma.

  8. Beam emittance measurements on multicusp ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Sarstedt, M.; Lee, Y.; Leung, K.N.; Perkins, L.T.; Pickard, D.S.; Weber, M.; Williams, M.D. [Lawrence Berkeley National Laboratory, University of California, Berkeley, California 94720 (United States)

    1996-03-01

    Multicusp ion sources are used for various applications. Presently, the implementation of this type of ion source is planned for the development of an ion beam lithography machine, which will be used for the projection of sub-0.2 {mu}m patterns onto a wafer substrate. Since, for this application, a very good beam quality and a small ion energy spread are required, emittance measurements have been performed on a multicusp ion source for various source conditions. It is shown that the installation of proper capacitors between the extraction electrodes is necessary to avoid rf pickup, which otherwise leads to a distortion of the beam emittance. The influence of the magnetic filter field on the beam emittance has been investigated, and the beam emittance of a dc filament-discharge plasma has also been compared to that of a rf-generated plasma. {copyright} {ital 1996 American Institute of Physics.}

  9. Beam emittance measurements on multicusp ion sources

    Science.gov (United States)

    Sarstedt, M.; Lee, Y.; Leung, K. N.; Perkins, L. T.; Pickard, D. S.; Weber, M.; Williams, M. D.

    1996-03-01

    Multicusp ion sources are used for various applications. Presently, the implementation of this type of ion source is planned for the development of an ion beam lithography machine, which will be used for the projection of sub-0.2 μm patterns onto a wafer substrate. Since, for this application, a very good beam quality and a small ion energy spread are required, emittance measurements have been performed on a multicusp ion source for various source conditions. It is shown that the installation of proper capacitors between the extraction electrodes is necessary to avoid rf pickup, which otherwise leads to a distortion of the beam emittance. The influence of the magnetic filter field on the beam emittance has been investigated, and the beam emittance of a dc filament-discharge plasma has also been compared to that of a rf-generated plasma.

  10. Measurement of initial absorption of fused silica at 193nm using laser induced deflection technique (LID)

    Science.gov (United States)

    Schönfeld, Dörte; Klett, Ursula; Mühlig, Christian; Thomas, Stephan

    2008-01-01

    The ongoing development in microlithography towards further miniaturization of structures creates a strong demand for lens material with nearly ideal optical properties. Beside the highly demanding requirements on homogeneity and stress induced birefringence (SIB), low absorption is a key factor. Even a small absorption is associated with a temperature increase and results in thermally induced local variations of refractive index and SIB. This could affect the achievable resolution of the lithographic process. The total absorption of the material is composed of initial absorption and of absorption induced during irradiation. Thus, the optimization of both improves the lifetime of the material. In principal, it is possible to measure transmission and scattering with a suitable spectrometer assembly and calculate absorption from them. However, owing to the influence of sample surfaces and errors of measurement, these methods usually do not provide satisfactory results for highly light-transmissive fused silica. Therefore, it is most desirable to find a technique that is capable of directly measuring absorption coefficients in the range of (1...10)•10 -4 cm -1 (base 10) directly. We report our first results for fused silica achieved with the LID technique. Besides a fused silica grade designed for 193 nm applications, grades with higher absorption at 193 nm were measured to test the LID technique. A special focus was set on the possibility of measuring initial absorption without the influence of degradation effects.

  11. Resonant cavity monitors for charged beam measurements.

    Science.gov (United States)

    Rutledge, Gary A.

    2003-04-01

    The G_zero experiment at Jefferson Lab, will measure the strange quark content of the proton as it contributes to the proton's charge and magnetic properties. Parity violating elastic electron scattering is being used to measure the physics asymmetry to better than 1 part in 10^7. Helicity correlated properties of the electron beam used in this experiment must be measured to better than 1 in 10^7 over the course of the experiment. G_zero employs two types of beam monitors for this purpose. Standard, 4-wire, ``strip-line'' monitors measure beam positions with a resolution of 20microns. Another type of monitor, Beam Resonant Cavities are being tested. Two sets of three cavities are used to measure beam position in X and Y, as well as beam current. Presented will be the performance and evaluation of these cavities including their theoretical versus actual operation, their noise characteristics, and signal resolution. These cavities can be paired with either linear or logarithmic amplifier electronics. Overall performance of these cavity systems including amplifiers will be compared with standard 'strip-line' monitors.

  12. Deflection of 450 GeV protons by planar channeling in a bent silicon crystal

    Science.gov (United States)

    Jensen, B. N.; Møller, S. P.; Uggerhøj, E.; Worm, T.; Atherton, H. W.; Clément, M.; Doble, N.; Elsener, K.; Gatignon, L.; Grafström, P.; Jeanneret, J. B.; Hage-Ali, M.; Siffert, P.

    1992-08-01

    A 450 GeV proton beam has been bent by various angles from 4 to 14 mrad using planar channeling in a (111) silicon crystal. Detailed investigations of the deflected beam as well as the unbent and scattered particles have been performed. The incident beam had a divergence of about 35 μrad (FWHM). 20% of the protons hitting the crystal front face were found to be initially channeled. The measured bending efficiencies range from 5 to 2% (for increasing deflection angles) are compared to theoretical estimates including surface acceptance and dechanneling in bent silicon crystals.

  13. Deflection of 450 GeV protons by planar channeling in a bent silicon crystal

    Energy Technology Data Exchange (ETDEWEB)

    Jensen, B.N.; Moeller, S.P.; Uggerhoej, E.; Worm, T. (Inst. for Synchrotron Radiation, Aarhus Univ. (Denmark)); Atherton, H.W.; Clement, M.; Doble, N.; Elsener, K.; Gatignon, L.; Grafstroem, P.; Jeanneret, J.B. (European Organization for Nuclear Research (CERN), Geneva (Switzerland)); Hage-Ali, M.; Siffert, P. (Centre de Recherches Nucleaires, 67 - Strasbourg (France))

    1992-08-01

    A 450 GeV proton beam has been bent by various angles from 4 to 14 mrad using planar channeling in a (111) silicon crystal. Detailed investigations of the deflected beam as well as the unbent and scattered particles have been performed. The incident beam had a divergence of about 35 [mu]rad (FWHM). 20% of the protons hitting the crystal front face were found to be initially channeled. The measured bending efficiencies range from 5 to 2% (for increasing deflection angles) and are compared to theoretical estimates including surface acceptance and dechanneling in bent silicon crystals. (orig.).

  14. Validity of a taekwondo specific test to measure vo2peak and the heart rate deflection point.

    Science.gov (United States)

    Sant'Ana, Jader; Franchini, Emerson; Murias, Juan; Diefenthaeler, Fernando

    2017-07-19

    This study investigated whether the progressive specific taekwondo test (PSTT) is a valid test to measure peak oxygen consumption (VO2PEAK) and the heart rate deflection point (HRDP) in taekwondo athletes. Eighteen male black belt athletes (25.3 ± 4.8 years; 8.2 ± 4.7 years of practice; 171.8 ± 4.7 cm; 76.1 ± 8.2 kg, and 13.1 ± 2.9% body fat) involved in regional and national level competitions performed the PSTT and an incremental treadmill test (IT). The following variables were analyzed: VO2PEAK, respiratory quotient, oxygen consumption at the HRDP (VO2HRDP), peak heart rate (HRPEAK), HRDP, and peak post-test blood lactate concentration. During the PSTT the peak kick frequency (FKPEAK) and kick frequency at the HRDP (FKHRDP) was also obtained. During the IT, the peak speed and the speed at the HRDP were identified by the DMAX method (the first and last points of the curve were connected by a straight line and the most distant point of the curve to the line was considered as the heart rate deflection point). No differences were observed between VO2 responses during the PSTT and IT (p>0.05). VO2PEAK and VO2HRDP presented bias (1.3 ml·kg·min and -0.78 ml·kg·min, respectively) derived from the Bland & Altman plots, with the 95% limits of agreement indicating that the differences between the two measures can reach 11% for VO2PEAK and 17% for VO2HRDP. The PSTT is a valid tool to assess aerobic power and capacity in taekwondo athletes based on direct comparisons to a treadmill test. The test presents more specific variables for the assessment and training of taekwondo athletes, such as FKPEAK and FKHRDP, which can be used to determine and control the effects of training and help coaches in prescribing training programs.

  15. High-efficiency deflection of high energy protons due to channeling along the axis of a bent silicon crystal

    Science.gov (United States)

    Scandale, W.; Arduini, G.; Butcher, M.; Cerutti, F.; Garattini, M.; Gilardoni, S.; Lechner, A.; Masi, A.; Mirarchi, D.; Montesano, S.; Redaelli, S.; Rossi, R.; Smirnov, G.; Breton, D.; Burmistrov, L.; Chaumat, V.; Dubos, S.; Maalmi, J.; Puill, V.; Stocchi, A.; Bagli, E.; Bandiera, L.; Germogli, G.; Guidi, V.; Mazzolari, A.; Dabagov, S.; Murtas, F.; Addesa, F.; Cavoto, G.; Iacoangeli, F.; Galluccio, F.; Afonin, A. G.; Chesnokov, Yu. A.; Durum, A. A.; Maisheev, V. A.; Sandomirskiy, Yu. E.; Yanovich, A. A.; Kovalenko, A. D.; Taratin, A. M.; Denisov, A. S.; Gavrikov, Yu. A.; Ivanov, Yu. M.; Lapina, L. P.; Malyarenko, L. G.; Skorobogatov, V. V.; James, T.; Hall, G.; Pesaresi, M.; Raymond, M.

    2016-09-01

    A deflection efficiency of about 61% was observed for 400 GeV/c protons due to channeling, most strongly along the axis of a bent silicon crystal. It is comparable with the deflection efficiency in planar channeling and considerably larger than in the case of the axis. The measured probability of inelastic nuclear interactions of protons in channeling along the axis is only about 10% of its amorphous level whereas in channeling along the (110) planes it is about 25%. High efficiency deflection and small beam losses make this axial orientation of a silicon crystal a useful tool for the beam steering of high energy charged particles.

  16. Bending and rotational behaviour of semi-continuous composite beams

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Stresses and deflections were measured in various semi-continuous composite beams.The bending and rotational capacities of the composite connections were measured in terms of beam curvatures and deflections by using two full-scale semi-rigid composite frames with monotonic loadings.The effect of semi-rigid connections on the performance of composite beams with various loadings was compared with predictions and codes.The tests show that the semi-continuous composite beams are more economic and effective than the simple or continuous composite beams.The semi-rigid connections affect the bending capacities and beam deflections,so the connection behavior should be considered in the design of composite beams.Yielding analysis of the steel beam bottom flange has some influence on the deflection calculation of composite beams.

  17. Photothermal deflection spectroscopy for the study of thin films and optical coatings: measurements of absorption losses and detection of photoinduced changes

    Science.gov (United States)

    Commandre, Mireille; Roche, Pierre J.; Albrand, Gerard; Pelletier, Emile P.

    1990-08-01

    Photothermal deflection has been used to map the absorption characteristics of thin film optical coatings. Our experimental set-up can give low level absorption coefficient down to 1 ppm, with a spatial resolution limited by the excitating laser beam diameter (100 tim). On single layer films, we can calculate extinction coefficient of the deposited material with a detectivity of a few i07. We present a study of absorption losses in single layer titania films and in TiOWSiO2 Fabry-Perot filters prepared in our laboratory by electron beam evaporation, ion assisted deposition and ion plating. Local variations of absorption on the sample surface can be very large especially in lowly absorbing samples; high absorption sites may be related to local defects responsible for laser damage. Furthermore, we show that some titania films can present photoinduced instabilities. Photothermal deflection spectroscopy is a good way to study absorption evolution under illumination. In Ti02/Si02 Fabry-Perot filters, we have observed that these absorption changes are associated with important drifts of transmission curves. So these instabilities can be explained by a change of the value of the complex index Ii = n - ik. Results lead to the conclusion that stability under illumination is strongly correlated to the deposition technique and also to the deposition conditions: unstable samples are mostly prepared by electron beam evaporation.

  18. Seven steps of alternating electron and proton transfer in photosystem II water oxidation traced by time-resolved photothermal beam deflection at improved sensitivity.

    Science.gov (United States)

    Klauss, André; Haumann, Michael; Dau, Holger

    2015-02-12

    The intricate orchestration of electron transfer (ET) and proton transfer (PT) at the Mn4CaOn-cluster of photosystem II (PSII) is mechanistically pivotal but clearly insufficiently understood. Preparations of PSII membrane particles were investigated using a kinetically competent and sensitive method, photothermal beam deflection (PBD), to monitor apparent volume changes of the PSII protein. Driven by nanosecond laser flashes, the PSII was synchronously stepped through its water-oxidation cycle involving four (semi)stable states (S0, S1, S2, and S3) and minimally three additional transiently formed intermediates. The PBD approach was optimized as compared to our previous experiments, resulting in superior signal quality and resolution of more reaction steps. Now seven transitions were detected and attributed, according to the H/D-exchange, temperature, and pH effects on their time constants, to ET or PT events. The ET steps oxidizing the Mn4CaOn cluster in the S2 → S3 and S0 → S1 transitions, a biphasic PT prior to the O2-evolving reaction, as well as the reoxidation of the primary quinone acceptor (QA(-)) at the PSII acceptor side were detected for the first time by PBD. The associated volume changes involve (i) initial formation of charged groups resulting in contraction assignable to electrostriction, (ii) volume contraction explainable by reduced metal-ligand distances upon manganese oxidation, and (iii) charge-compensating proton removal resulting in volume expansion due to electrostriction reversal. These results support a reaction cycle of water oxidation exhibiting alternate ET and PT steps. An extended kinetic scheme for the O2-evolving S3 ⇒ S0 transition is proposed, which includes crucial structural and protonic events.

  19. Vertical Beam Size Measurement by Streak Camera under Colliding and Single Beam Conditions in KEKB

    CERN Document Server

    Ikeda, Hitomi; Fukuma, Hitoshi; Funakoshi, Yoshihiro; Hiramatsu, Shigenori; Mitsuhashi, Toshiyuki; Ohmi, Kazuhito; Uehara, Sadaharu

    2005-01-01

    Beam behavior of KEKB was studied by measurement of the beam size using a streak camera. Effect of the electron-cloud and the parasitic collision on the vertical beam size was examined in beam collision. We intentionally injected a test bunch of positrons after 2 rf buckets of a bunch to enhance the electron cloud effect and changed electron beam conditions to see the beam-beam effect. The beam size was also measured with a single positron beam and compared with that during collision. The result of the measurement is reported in this paper.

  20. Beam Loss Diagnostics Based on Pressure Measurements

    CERN Document Server

    Weinrich, U

    2003-01-01

    The GSI is operating a heavy ion synchrotron, which is currently undergoing an upgrade towards higher beam intensities. It was discovered that beam losses induce a significant pressure increase in the vacuum system. In order to detect the time constants of the pressure increase and decrease, fast total pressure measurements were put into operation. With the recently installed partial pressure diagnostics it is also possible to follow up which types of molecules are released. The presentation will focus on the different techniques applied as well as on some measurement results. The potential and difficulties of this diagnostic tool will also be discussed.

  1. Energy-spread measurement of triple-pulse electron beams based on the magnetic dispersion principle

    CERN Document Server

    Wang, Yi; Yang, Zhiyong; Zhang, Huang; Ding, Hengsong; Yang, Anmin; Wang, Minhong

    2016-01-01

    The energy-spread of the triple-pulse electron beam generated by the Dragon-II linear induction accelerator is measured using the method of energy dispersion in the magnetic field. A sector magnet is applied for energy analyzing of the electron beam, which has a bending radius of 300 mm and a deflection angle of 90 degrees. For each pulse, both the time-resolved and the integral images of the electron position at the output port of the bending beam line are recorded by a streak camera and a CCD camera, respectively. Experimental results demonstrate an energy-spread of less than +-2.0% for the electron pulses. The cavity voltage waveforms obtained by different detectors are also analyzed for comparison.

  2. Transverse beam shape measurements of intense proton beams using optical transition radiation

    Energy Technology Data Exchange (ETDEWEB)

    Scarpine, Victor E.; /Fermilab

    2012-03-01

    A number of particle physics experiments are being proposed as part of the Department of Energy HEP Intensity Frontier. Many of these experiments will utilize megawatt level proton beams onto targets to form secondary beams of muons, kaons and neutrinos. These experiments require transverse size measurements of the incident proton beam onto target for each beam spill. Because of the high power levels, most beam intercepting profiling techniques will not work at full beam intensity. The possibility of utilizing optical transition radiation (OTR) for high intensity proton beam profiling is discussed. In addition, previous measurements of OTR beam profiles from the NuMI beamline are presented.

  3. Diffusion measurement from observed transverse beam echoes

    Science.gov (United States)

    Sen, Tanaji; Fischer, Wolfram

    2017-01-01

    We study the measurement of transverse diffusion through beam echoes. We revisit earlier observations of echoes in the Relativistic Heavy Ion Collider and apply an updated theoretical model to these measurements. We consider three possible models for the diffusion coefficient and show that only one is consistent with measured echo amplitudes and pulse widths. This model allows us to parameterize the diffusion coefficients as functions of the bunch charge. We demonstrate that echoes can be used to measure diffusion much quicker than present methods and could be useful to a variety of hadron synchrotrons.

  4. The Asteroid Impact Mission (AIM): Studying the geophysics of small binaries, measuring asteroid deflection and studying impact physics

    Science.gov (United States)

    Kueppers, Michael; Michel, Patrick; AIM Team

    2016-10-01

    Binary asteroids and their formation mechanisms are of particular interest for understanding the evolution of the small bodies in the solar system. Also, hazards to Earth from impact of near-Earth asteroids and their mitigation have drawn considerable interest over the last decades.Those subjects are both addressed by ESA's Asteroid Impact mission, which is part of the Asteroid Impact & Deflection Assessment (AIDA) currently under study in collaboration between NASA and ESA. NASA's DART mission will impact a projectile into the minor component of the binary near-Earth asteroid (65803) Didymos in 2022. The basic idea is to demonstrate the effect of the impact on the orbital period of the secondary around the primary. ESA's AIM will monitor the Didymos system for several months around the DART impact time.AIM will be launched in aurumn 2020. It is foreseen to arrive at Didymos in April 2022. The mission takes advantage of a close approach of Didymos to Earth. The next opportunity would arise in 2040 only.AIM will stay near Didymos for approximately 6 months. Most of the time it will be placed on the illuminated side of the system, at distances of approximately 35 km and 10 km. AIM is expected to move away from Didymos for some time around the DART impact.The reference payload for AIM includes two visual imagers, a hyperspectral camera, a lidar, a thermal infrared imager, a monostatic high frequency radar, and a bistatic low frequency radar. In addition, AIM will deploy a small lander on the secondary asteroid, and two cubesats that will be used for additional, more risky investigations close to or on the surface of the asteroid.Major contributions from AIM are expected in the study of the geophysics of small asteroids (including for the first time, radar measurements of an interior structure), the formation of binary asteroids, the momentum enhancement factor from the DART impact (through measuring the mass and the change of orbit of the seondary), and impact physics

  5. Application of photothermal deflection spectroscopy to electrochemical interfaces

    Energy Technology Data Exchange (ETDEWEB)

    Rudnicki, J.D.; McLarnon, F.R.; Cairns, E.J.

    1992-03-01

    This dissertation discusses the theory and practice of Photothermal Deflection Spectroscopy (PDS, which is also known as probe beam deflection spectroscopy, PBDS, probe deflection technique, and mirage effect spectroscopy) with respect to electrochemical systems. Much of the discussion is also relevant to non-electrochemical systems. PDS can measure the optical absorption spectrum of interfaces and concentration gradients in the electrolyte adjacent to the electrode. These measurements can be made on a wide variety of electrode surfaces and can be performed under dynamic conditions. The first three chapters discuss the theory of the phenomena that can be detected by PDS, and the equipment used in a PDS system. A ``secondary gradient technique`` is proposed, which places the probe beam on the back of an electrode. The results of a numerical model yield a method for determining the offset of the probe beam from the electrode surface based on the frequency response of the PDS signal. The origin and control of noise in the PDS signal are discussed. A majority of the signal noise appears to be acoustic in origin. The electrochemical oxidation of platinum is used to demonstrate that PDS has sub-monolayer sensitivity necessary to study interfacial chemistry. The results allow us to propose a two-reaction oxidation mechanism: the platinum is electrochemically oxidized to form platinum dihydroxide and dehydrated by a non-electrochemical second-order reaction. The final chapter discusses the relation of PDS to similar and competing techniques, and considers possibilities for the future of the technique.

  6. LEDA beam diagnostics instrumentation: Measurement comparisons and operational experience

    Science.gov (United States)

    Gilpatrick, J. D.; Barr, D.; Bruhn, D.; Day, L. A.; Kasemir, K. U.; Kamperschroer, J. H.; Ledford, J.; Lysenko, W.; Madsen, D. W.; Martinez, D. G.; O'Hara, J. F.; Pieck, M.; Power, J. F.; Sellyey, W.; Shurter, R. B.; Stettler, M. W.

    2000-11-01

    The Low Energy Demonstration Accelerator (LEDA) facility has been used to characterize the pulsed- and cw-beam performance of a 6.7 MeV, 100 mA radio frequency quadrupole (RFQ). Diagnostic instrumentation, primarily located in a short beam transport downstream of the RFQ, allow facility commissioners and operators to measure and monitor the RFQ's accelerated and total beam transmission, beam loss, bunched beam current, beam energy and output phase, and beam position. Transverse beam profile measurements are acquired under both low and high duty-factor pulsed beam conditions using a slow wire scanner and a camera that images beam-induced fluorescence. The wire scanner is also used to acquire transverse beam emittance information using a technique known as a "quad scan". This paper reviews the measurement performance and discusses the resulting data.

  7. Measurement of HL-2A NBI Beam Profile and Beam Power

    Institute of Scientific and Technical Information of China (English)

    LIU He; CAO Jianyong; JIANG Shaofeng; LUO Cuiwen; TANG Lixin; LEI Guangjiu; RAO Jun; LI Bo

    2009-01-01

    To optimize the operation parameters of the beam line of NBI on HL-2A,features of the beam line,including the beam profile and the power deposited on components and injected into the tokamak plasma,were measured.The operational parameters of the four sources on the beam line were optimized with the monitor of the beam profile and beam power,and the transmission efficiency of the NBI injected power was therefore increased.A beam diagnostic system for the beam line of the NBI system on HL-2A as well as the diagnosed results was also presented.

  8. Definition and measurement of the beam propagation factor M2 for chromatic laser beams

    Institute of Scientific and Technical Information of China (English)

    Tao Fang; Xin Ye; Jinfu Niu; Jianqiu Xu

    2006-01-01

    The concept of the beam propagation factor M2 is extended for chromatic laser beams. The definition of the beam propagation factor can be generalized with the weighted effective wavelength. Using the new definition of factor M2, the propagation of chromatic beams can be analyzed by the beam propagation factor M2 as same as that of monochromatic beams. A simple method to measure the chromatic beam factor M2 is demonstrated. The chromatic factor M2 is found invariable while the laser beam propagates through the dispersion-free ABCD system.

  9. Impact of beam-beam effects on precision luminosity measurements at the ILC

    CERN Document Server

    Rimbault, C; Mönig, K; Schulte, D

    2007-01-01

    In this paper, the impact of beam-beam effects on the precision luminosity measurement at the International Linear Collider is investigated quantitatively for the first time. GUINEA-PIG, a beam-beam interaction simulation tool, is adapted to treat the space charge effects affecting the Bhabha events used in this measurement. The biases due to the resulting changes in kinematics are evaluated for different center-of-mass energies and beam parameters.

  10. Turbulence measurements using six lidar beams

    DEFF Research Database (Denmark)

    Sathe, Ameya; Mann, Jakob

    2012-01-01

    The use of wind lidars for measuring wind has increased significantly for wind energy purposes. The mean wind speed measurement using the velocity azimuth display (VAD) technique can now be carried out as reliably as the traditional instruments like the cup and sonic anemometers. Using the VAD...... technique the turbulence measurements are far from being reliable. Two mechanisms contribute to systematic errors in the measurement of turbulence. One is the averaging of small scales of turbulence due to the volume within which lidars measure wind speed. The other is the contamination by the cross...... components of the Reynolds stress tensor, which arises because, in a VAD scan the lidar beams are combined to obtain different components of the wind field. In this work we demonstrate theoretically, how the contamination by the cross components can be avoided by using the measured variances of the line...

  11. Research on static measuring method of wire saw deflection angle%绳锯线弓角静态测量方法的研究

    Institute of Scientific and Technical Information of China (English)

    金闪闪; 邹航; 郭桦

    2016-01-01

    When diamond wire saw cuts circular arc ,wire saw deflection angle will be formed due to resistance in the feed direction .If the bending is serious enough ,the center of the circular plate will be cut excessively and leads to material scrap .In order to solve the problem ,wire saw deflection angle is defined .The static measuring methodology of wire saw deflection angle was proposed .This methodology was based on cantilever type axis force sensor .Through the axis force sensor ,voltage values were output and recorded to calculate wire saw deflection angle . Static measuring experiments were carried out in the physical equipment designed and built by au‐thors .In the experiments ,the steel rope was used to simulate diamond wire saw and created wire saw deflection angle .T he static measuring experiments w ere carried out to study the relationship between the force of guide wheel and wire saw deflection angle .It was found that ,the measured angle was close to the theoretical angle with the increase of initial tension within certain range . Therefore ,when the edge of guide wheel whose axis assembles the force sensor is just contacted with steel cable ,the wire saw deflection angle can be measured relative accurately by this meth‐od .%金刚石绳锯在切割圆弧板材时,受到进给方向的阻力,形成“线弓角”,使板材中部产生“过切”,严重时导致材料报废。为解决这一问题,提出了线弓角的概念,从理论上提出了一种基于悬臂式力传感器的绳锯线弓角的静态测量方法,通过轴力传感器输出的电压值计算出线弓角度。试验在自行设计和搭建的绳锯线弓角测量平台上进行,用钢丝绳模拟串珠绳产生线弓角,并进行导轮受力与线弓角关系的静态测量试验分析,以验证该方法测量线弓角的可行性。试验结果表明:在一定范围内,串珠绳初始张紧力越大,线弓角的计算值越接近理论值。因此,

  12. Beam Emittance Measurement with Laser Wire Scanners in the ILC Beam Delivery System

    Energy Technology Data Exchange (ETDEWEB)

    Agapov, I.; /CERN; Blair, G.A.; /Royal Holloway, U. of London; Woodley, M.; /SLAC

    2008-02-01

    Accurate measurement of the beam phase-space is essential for the next generation of electron accelerators. A scheme for beam optics optimization and beam matrix reconstruction algorithms for the diagnostics section of the beam delivery system of the International Linear Collider based on laser-wire beam profile monitors are discussed. Possible modes of operation of the laser-wire system together with their corresponding performance are presented. Based on these results, prospects for reconstructing the ILC beam emittance from representative laser-wire beam size measurements are evaluated.

  13. Research on Brightness Measurement of Intense Electron Beam

    CERN Document Server

    Wang, Yuan; Zhang, Huang; Yang, GuoJun; Li, YiDing; Li, Jin

    2015-01-01

    The mostly research fasten on high emission density of injector to study electron beam's brightness in LIA. Using the injector(2MeV) was built to research brightness of multi-pulsed high current(KA) electron beam, and researchs three measurement method (the pepper-pot method, beam collimator without magnetic field, beam collimator with magnetic field method) to detect beam's brightness with time-resolved measurement system.

  14. Residual Strains in a Nanometer Thick Cr Film Measured on Micromachined Beams

    Institute of Scientific and Technical Information of China (English)

    Z.M. Zhou; Yong Zhou; Ying Cao; Haiping Mao

    2009-01-01

    A Cr film with a 75 nm thickness sputtered on a Si substrate was used to fabricate microbridge and microcan-tilever samples with the MEMS (microelectromechanical system) technique. The profile of the buckled beams was measured by using the interference technique with white light and fitted with a theoretical result. The uniform residual strain in the bridge samples was deduced from the variation of buckling amplitude with the beam length. On the other hand, the gradient residual strain was determined from the deflection profile of the cantilever. The residual uniform and gradient strain in the Cr film are about 4.96×10-3 and 4.2967×10-5, respectively.

  15. Commissioning experience and beam physics measurements at the SwissFEL Injector Test Facility

    Directory of Open Access Journals (Sweden)

    T. Schietinger

    2016-10-01

    Full Text Available The SwissFEL Injector Test Facility operated at the Paul Scherrer Institute between 2010 and 2014, serving as a pilot plant and test bed for the development and realization of SwissFEL, the x-ray Free-Electron Laser facility under construction at the same institute. The test facility consisted of a laser-driven rf electron gun followed by an S-band booster linac, a magnetic bunch compression chicane and a diagnostic section including a transverse deflecting rf cavity. It delivered electron bunches of up to 200 pC charge and up to 250 MeV beam energy at a repetition rate of 10 Hz. The measurements performed at the test facility not only demonstrated the beam parameters required to drive the first stage of an FEL facility, but also led to significant advances in instrumentation technologies, beam characterization methods and the generation, transport and compression of ultralow-emittance beams. We give a comprehensive overview of the commissioning experience of the principal subsystems and the beam physics measurements performed during the operation of the test facility, including the results of the test of an in-vacuum undulator prototype generating radiation in the vacuum ultraviolet and optical range.

  16. Microstructure cantilever beam for current measurement

    Directory of Open Access Journals (Sweden)

    M.T.E. Khan

    2010-01-01

    Full Text Available Most microelectromechanical systems (MEMS sensors are based on the microcantilever technology, which uses a broad range of design materials and structures. The benefit ofMEMStechnology is in developing devices with a lower cost, lower power consumption, higher performance and greater integration. A free-end cantilever beam with a magnetic material mass has been designed using MEMS software tools. The magnetic material was used to improve the sensitivity of the cantilever beam to an externally-applied magnetic field. The cantilever was designed to form a capacitance transducer, which consisted of variable capacitance where electrical and mechanical energies were exchanged. The aim of this paper was to analyse the system design of the microcantilever when subjected to a magnetic field produced by a current-carrying conductor. When the signal, a sinusoidal current with a constant frequency, was applied, the cantilever beam exhibited a vibration motion along the vertical axis when placed closer to the line current. This motion created corresponding capacitance changes and generated a voltage output proportional to the capacitive change in the signal-processing circuitry attached to the microcantilever. The equivalent massspring system theory was used to describe and analyse the effect of the natural frequency of the system vibrations and motion due to the applied magnetic field, in a single-degree of freedom. The main application of this microcantilever is in current measurements to develop a non-contact current sensor mote.

  17. Measurement of / values using proton beam

    Indian Academy of Sciences (India)

    G A V Ramanamurthy; K Ramachandra Rao; Y Rama Krishna; P Venkateswarlu; K Bhaskara Rao; P V Ramana Rao; S Venkata Ratnam; V Seshagiri Rao; G J Nagaraju; S Bhuloka Reddy

    2001-05-01

    The / intensity ratios are measured in some 3 shell elements by using a 2 MeV proton beam along with a high resolution Si(Li) detector. The present / intensity ratios are in good agreement with Scofield modified theoretical values, thus supporting the basic assumptions in that theory. From the present / intensity ratios, it is evident that due to chemical effects, the experimental / intensity ratios will be increased while they will be decreased due to the presence of simultaneous -shell vacancies which are produced due to proton excitation.

  18. Preservation of beam loss induced quenches, beam lifetime and beam loss measurements with the HERAp beam-loss-monitor system

    Science.gov (United States)

    Wittenburg, Kay

    1994-06-01

    The beam-loss-monitors (BLMs) in the HERA-proton-ring (HERAp) must fulfill the following requirements: They have to measure losses sensitive and fast enough to prevent the superconducting magnets from beam loss induced quenching; the dynamic range of the monitors must exceed several decades in order to measure losses during beam lifetimes of hundreds of hours as well as the much stronger losses that may quench superconducting magnets; they have to be insensitive to the synchrotron radiation of the adjacent electron-ring (HERAe); and their radiation hardness must allow a monitor-lifetime of a few years of HERA operation. These requirements are well satisfied by the HERAp-BLM-System.

  19. PERMEABILITY OF SALTSTONE MEASUREMENT BY BEAM BENDING

    Energy Technology Data Exchange (ETDEWEB)

    Harbour, J; Tommy Edwards, T; Vickie Williams, V

    2008-01-30

    One of the goals of the Saltstone variability study is to identify (and, quantify the impact of) the operational and compositional variables that control or influence the important processing and performance properties of Saltstone mixes. A performance property for Saltstone mixes that is important but not routinely measured is the liquid permeability or saturated hydraulic conductivity of the cured Saltstone mix. The value for the saturated hydraulic conductivity is an input into the Performance Assessment for the SRS Z-Area vaults. Therefore, it is important to have a method available that allows for an accurate and reproducible measurement of permeability quickly and inexpensively. One such method that could potentially meet these requirements for the measurement of saturated hydraulic conductivity is the technique of beam bending, developed by Professor George Scherer at Princeton University. In order to determine the feasibility of this technique for Saltstone mixes, a summer student, David Feliciano, was hired to work at Princeton under the direction of George Scherer. This report details the results of this study which demonstrated the feasibility and applicability of the beam bending method to measurement of permeability of Saltstone samples. This research effort used samples made at Princeton from a Modular Caustic side solvent extraction Unit based simulant (MCU) and premix at a water to premix ratio of 0.60. The saturated hydraulic conductivities for these mixes were measured by the beam bending technique and the values determined were of the order of 1.4 to 3.4 x 10{sup -9} cm/sec. These values of hydraulic conductivity are consistent with independently measured values of this property on similar MCU based mixes by Dixon and Phifer. These values are also consistent with the hydraulic conductivity of a generic Saltstone mix measured by Langton in 1985. The high water to premix ratio used for Saltstone along with the relatively low degree of hydration for

  20. Deflecting cavity dynamics for time-resolved machine studies of SXFEL user facility

    CERN Document Server

    Song, Minghao; Liu, Bo; Wang, Dong

    2016-01-01

    Radio frequency deflectors are widely used for time-resolved electron beam energy, emittance and radiation profile measurements in modern free electron laser facilities. In this paper, we present the beam dynamics aspects of the deflecting cavity of SXFEL user facility, which is located at the exit of the undulator. With a targeted time resolution around 10 fs, it is expected to be an important tool for time-resolved commissioning and machine studies for SXFEL user facility.

  1. Laser beam complex amplitude measurement by phase diversity.

    Science.gov (United States)

    Védrenne, Nicolas; Mugnier, Laurent M; Michau, Vincent; Velluet, Marie-Thérèse; Bierent, Rudolph

    2014-02-24

    The control of the optical quality of a laser beam requires a complex amplitude measurement able to deal with strong modulus variations and potentially highly perturbed wavefronts. The method proposed here consists in an extension of phase diversity to complex amplitude measurements that is effective for highly perturbed beams. Named camelot for Complex Amplitude MEasurement by a Likelihood Optimization Tool, it relies on the acquisition and processing of few images of the beam section taken along the optical path. The complex amplitude of the beam is retrieved from the images by the minimization of a Maximum a Posteriori error metric between the images and a model of the beam propagation. The analytical formalism of the method and its experimental validation are presented. The modulus of the beam is compared to a measurement of the beam profile, the phase of the beam is compared to a conventional phase diversity estimate. The precision of the experimental measurements is investigated by numerical simulations.

  2. Commissioning experience and beam physics measurements at the SwissFEL Injector test Facility

    CERN Document Server

    Schietinger, T.; Aiba, M.; Arsov, V.; Bettoni, S.; Beutner, B.; Calvi, M.; Craievich, P.; Dehler, M.; Frei, F.; Ganter, R.; Hauri, C. P.; Ischebeck, R.; Ivanisenko, Y.; Janousch, M.; Kaiser, M.; Keil, B.; Löhl, F.; Orlandi, G. L.; Ozkan Loch, C.; Peier, P.; Prat, E.; Raguin, J.-Y.; Reiche, S.; Schilcher, T.; Wiegand, P.; Zimoch, E.; Anicic, D.; Armstrong, D.; Baldinger, M.; Baldinger, R.; Bertrand, A.; Bitterli, K.; Bopp, M.; Brands, H.; Braun, H. H.; Brönnimann, M.; Brunnenkant, I.; Chevtsov, P.; Chrin, J.; Citterio, A.; Csatari Divall, M.; Dach, M.; Dax, A.; Ditter, R.; Divall, E.; Falone, A.; Fitze, H.; Geiselhart, C.; Guetg, M. W.; Hämmerli, F.; Hauff, A.; Heiniger, M.; Higgs, C.; Hugentobler, W.; Hunziker, S.; Janser, G.; Kalantari, B.; Kalt, R.; Kim, Y.; Koprek, W.; Korhonen, T.; Krempaska, R.; Laznovsky, M.; Lehner, S.; Le Pimpec, F.; Lippuner, T.; Lutz, H.; Mair, S.; Marcellini, F.; Marinkovic, G.; Menzel, R.; Milas, N.; Pal, T.; Pollet, P.; Portmann, W.; Rezaeizadeh, A.; Ritt, S.; Rohrer, M.; Schär, M.; Schebacher, L.; Scherrer, St.; Schlott, V.; Schmidt, T.; Schulz, L.; Smit, B.; Stadler, M.; Steffen, Bernd; Stingelin, L.; Sturzenegger, W.; Treyer, D. M.; Trisorio, A.; Tron, W.; Vicario, C.; Zennaro, R.; Zimoch, D.

    2016-10-26

    The SwissFEL Injector Test Facility operated at the Paul Scherrer Institute between 2010 and 2014, serving as a pilot plant and test bed for the development and realization of SwissFEL, the x-ray Free Electron Laser facility under construction at the same institute. The test facility consisted of a laser-driven rf electron gun followed by an S-band booster linac, a magnetic bunch compression chicane and a diagnostic section including atransverse deflecting rf cavity. It delivered electron bunchesof up to200 pC chargeand up to 250 MeV beam energy at a repetition rate of 10 Hz. The measurements performed at the test facility not only demonstrated the beam parameters required to drive the first stage of a FEL facility, but also led to significant advances in instrumentation technologies, beam characterization methods and the generation, transport and compression of ultralow-emittance beams. We give a comprehensive overview of the commissioning experience of the principal subsystems and the beam physics measureme...

  3. Commissioning experience and beam physics measurements at the SwissFEL Injector Test Facility

    CERN Document Server

    Schietinger, T; Aiba, M; Arsov, V; Bettoni, S; Beutner, B; Calvi, M; Craievich, P; Dehler, M; Frei, F; Ganter, R; Hauri, C P; Ischebeck, R; Ivanisenko, Y; Janousch, M; Kaiser, M; Keil, B; Löhl, F; Orlandi, G L; Loch, C Ozkan; Peier, P; Prat, E; Raguin, J -Y; Reiche, S; Schilcher, T; Wiegand, P; Zimoch, E; Anicic, D; Armstrong, D; Baldinger, M; Baldinger, R; Bertrand, A; Bitterli, K; Bopp, M; Brands, H; Braun, H H; Brönnimann, M; Brunnenkant, I; Chevtsov, P; Chrin, J; Citterio, A; Divall, M Csatari; Dach, M; Dax, A; Ditter, R; Divall, E; Falone, A; Fitze, H; Geiselhart, C; Guetg, M W; Hämmerli, F; Hauff, A; Heiniger, M; Higgs, C; Hugentobler, W; Hunziker, S; Janser, G; Kalantari, B; Kalt, R; Kim, Y; Koprek, W; Korhonen, T; Krempaska, R; Laznovsky, M; Lehner, S; Pimpec, F Le; Lippuner, T; Lutz, H; Mair, S; Marcellini, F; Marinkovic, G; Menzel, R; Milas, N; Pal, T; Pollet, P; Portmann, W; Rezaeizadeh, A; Ritt, S; Rohrer, M; Schär, M; Schebacher, L; Scherrer, St; Schmidt, V Schlott T; Schulz, L; Smit, B; Stadler, M; Steffen, B; Stingelin, L; Sturzenegger, W; Treyer, D M; Trisorio, A; Tron, W; Vicario, C; Zennaro, R; Zimoch, D

    2016-01-01

    The SwissFEL Injector Test Facility operated at the Paul Scherrer Institute between 2010 and 2014, serving as a pilot plant and testbed for the development and realization of SwissFEL, the X-ray Free-Electron Laser facility under construction at the same institute. The test facility consisted of a laser-driven rf electron gun followed by an S-band booster linac, a magnetic bunch compression chicane and a diagnostic section including a transverse deflecting rf cavity. It delivered electron bunches of up to 200 pC charge and up to 250 MeV beam energy at a repetition rate of 10 Hz. The measurements performed at the test facility not only demonstrated the beam parameters required to drive the first stage of an FEL facility, but also led to significant advances in instrumentation technologies, beam characterization methods and the generation, transport and compression of ultra-low-emittance beams. We give a comprehensive overview of the commissioning experience of the principal subsystems and the beam physics meas...

  4. Investigation of average growth stresses in Cr2O3 scales measured by a novel deflection method

    Institute of Scientific and Technical Information of China (English)

    钱余海; 李美栓; 刘光明; 辛丽

    2002-01-01

    The stress in the oxide film plays an important role to keep it intact so it is necessary to determine the stress in the oxide scale. Average growth stresses in Cr2O3 scales formed on Ni-base alloy (Ni80Cr20) at 1000℃ in air were investigated by a novel deflection technique. It is found that the growth stress in the oxide scale is basically compressive and its average order is 100MPa. The stress values are high for the thin scales and become low for thick scales after oxidized for 10h. The planar stress distribution in metals is complex. It is both compressive and tensile at the beginning of oxidation procedure, and then become only tensile during further oxidation.

  5. Faraday Cup - it is used to measure beam intensities at low energy beams.

    CERN Multimedia

    Maximilien Brice

    2005-01-01

    A Faraday Cup is used to measure beam intensities at low energy beams. An electrically isolated metallic electrode intercepts the beam and captures all its charges. These charges are integrated using an current sensitive amplifier. When the beam impinges onto the electrode surface low energy electrons are liberated. In order to prevent these electrons from escaping the cup and thus falsifying the measurement, a repeller electrode with negative potential pushes the electrons back onto the electrode.

  6. Emittance measurements of the CLIO electron beam

    Science.gov (United States)

    Chaput, R.; Devanz, G.; Joly, P.; Kergosien, B.; Lesrel, J.

    1997-02-01

    We have designed a setup to measure the transverse emittance at the CLIO accelerator exit, based on the "3 gradients" method. The beam transverse size is measured simply by scanning it with a steering coil across a fixed jaw and recording the transmitted current, at various quadrupole strengths. A code then performs a complete calculation of the emittance using the transfer matrix of the quadrupole instead of the usual classical lens approximation. We have studied the influence of various parameters on the emittance: Magnetic field on the e-gun and the peak current. We have also improved a little the emittance by replacing a mismatched pipe between the buncher and accelerating section to avoid wake-field effects; The resulting improvements of the emittance have led to an increase in the FEL emitted power.

  7. Ion beam measurements at the superconducting ECR ion source SECRAL

    Energy Technology Data Exchange (ETDEWEB)

    Maeder, Jan; Rossbach, Jon; Lang, Ralf; Maimone, Fabio; Spaedtke, Peter; Tinschert, Klaus [Gesellschaft fuer Schwerionenforschung mbH, Darmstadt (Germany); Sun, Liangting; Cao, Yun; Zhao, Hongwei [Institute of Modern Physics, Lanzhou, GS (China)

    2009-08-15

    Measurement of the charge-state distribution, the beam profile, the beam emittance of the named ion source are presented. Furthermore computer simulations of the magnetic flux-density distribution in this source are described. (HSI)

  8. Paraffin oil thermal diffusivity determination using a photothermal deflection setup with a 2.3{mu}m pump: a first step towards methane detection

    Energy Technology Data Exchange (ETDEWEB)

    Hamdi, A; Yacoubi, N [Equipe de Photothermie de Nabeul 99/UR/13-22, IPEIN, Mrezka-8000 (Tunisia); Rouillard, Y; Vicet, A [Universite de Montpellier II IES-UMR CNRS 5214/Place Eugene Bataillon - cc 067-F-34095 Montpellier cedex 5 (France); Genty, F, E-mail: abdelwaheb_hamdi@yahoo.f

    2010-03-01

    The photothermal deflection technique, also known as 'mirage effect', is a nondestructive method of evaluating thermal properties of solid, liquid or gaseous species. This technique will be used to detect pollutant absorption. As the deflection is stronger in liquids than gases, we will first consider the deflection in paraffin oil. We consider a medium that is heated by a modulated laser diode beam, and we measure the deflection of the probe beam passing through the heated region as a function of the distance between the axes of the beams. After some theoretical considerations and numerical simulations, we present the application of this method to the experimental determination of the thermal diffusivity of a liquid sample in excellent agreement with previously known values.

  9. Deflections of Nanowires with Consideration of Surface Effects

    Institute of Scientific and Technical Information of China (English)

    LI He; YANG Zhou; ZHANG Yi-Min; WEN Bang-Chun

    2010-01-01

    @@ The elementary beam model is modified to include the surface effects and used to analyze the deflections of nanowires under different boundary conditions.The results show that compared to deflections of nanowires without consideration of surface effects,the surface effects can enlarge or reduce deflections of nanowires,and nanowire buckling occurs under certaJn conditions.This study might be helpful for design of nanowire-based nanoelectromechanical systems.

  10. Beam Phase Measurements in the AGOR Cyclotron

    CERN Document Server

    Brandenburg, S; Van Asselt, W K

    2003-01-01

    Beamphase measurement to optimize the isochronism is an essential part of the diagnostics in multi-particle, multi-energy cyclotrons. In the AGOR cyclotron an array of 13 nondestructive beamphase pick-ups is installed. To reduce the large disturbances from the RF-system the measurements are traditionally performed at the 2nd harmonic of the RF-frequency. To further improve the sensitivity intensity modulation of the beam has been introduced. This creates side-bands in the Fourier spectrum, that are completely free of interference from the RF-system. These side-bands contain information on both the beamphase with respect to the accelerating voltage and the number of revolutions up to the radius of the measurement. A specific case is intensity modulation at the orbital frequency, where the side-bands contain only information on the beamphase. Measurements with the different methods will be presented, demonstrating that the intensity modulation strongly improves the sensitivity of the measurement. Useful beampha...

  11. Alternative techniques for beam halo measurements

    CERN Document Server

    Welsch, CP; Burel, B; Lefèvre, T; Chapman, T; Pilon, MJ

    2006-01-01

    In future high intensity, high energy accelerators it must be ensured that particle losses are minimized, as activation of the vacuum chambers or other components makes maintenance and upgrade work time consuming and costly. It is imperative to have a clear understanding of the mechanisms that can lead to halo formation and to have the possibility to test available theoretical models with an adequate experimental setup. Measurements based on optical transition radiation (OTR) are a well-established technique for measurements of the transverse beam profile. However, in order to be suitable for halo measurements as well, the dynamic range of the final image acquisition system needs to be high, being able to cover at least five orders of magnitude in intensity changes. Here, the performance of a standard acquisition system as it is used in the CLIC test facility (CTF3) is compared to a step-by-step measurement with a small movable photo multiplier tube and an innovative camera system based on charge injection de...

  12. Electron beam based transversal profile measurements of intense ion beams; Elektronenstrahl-Diagnostik zur Bestimmung vom transversalen Profil intensiver Ionenstrahlen

    Energy Technology Data Exchange (ETDEWEB)

    El Moussati, Said

    2014-11-03

    A non-invasive diagnostic method for the experimental determination of the transverse profile of an intense ion beam has been developed and investigated theoretically as well as experimentally within the framework of the present work. The method is based on the deflection of electrons when passing the electromagnetic field of an ion beam. To achieve this an electron beam is employed with a specifically prepared transversal profile. This distinguish this method from similar ones which use thin electron beams for scanning the electromagnetic field [Roy et al. 2005; Blockland10]. The diagnostic method presented in this work will be subsequently called ''Electron-Beam-Imaging'' (EBI). First of all the influence of the electromagnetic field of the ion beam on the electrons has been theoretically analyzed. It was found that the magnetic field causes only a shift of the electrons along the ion beam axis, while the electric field only causes a shift in a plane transverse to the ion beam. Moreover, in the non-relativistic case the magnetic force is significantly smaller than the Coulomb one and the electrons suffer due to the magnetic field just a shift and continue to move parallel to their initial trajectory. Under the influence of the electric field, the electrons move away from the ion beam axis, their resulting trajectory shows a specific angle compared to the original direction. This deflection angle practically depends just on the electric field of the ion beam. Thus the magnetic field has been neglected when analysing the experimental data. The theoretical model provides a relationship between the deflection angle of the electrons and the charge distribution in the cross section of the ion beam. The model however only can be applied for small deflection angles. This implies a relationship between the line-charge density of the ion beam and the initial kinetic energy of the electrons. Numerical investigations have been carried out to clarify the

  13. Beam distribution reconstruction simulation for electron beam probe

    CERN Document Server

    Feng, Yongchun; Li, Peng; Kang, Xincai; Yin, Yan; Liu, Tong; You, Yaoyao; Chen, Yucong; Zhao, Tiecheng; Xu, Zhiguo; Wang, Yanyu; Yuan, Youjin

    2016-01-01

    Electron beam probe (EBP) is a new principle detector, which makes use of a low-intensity and low-energy electron beam to measure the transverse profile, bunch shape, beam neutralization and beam wake field of an intense beam with small dimensions. While can be applied to many aspects, we limit our analysis to beam distribution reconstruction. This kind of detector is almost non-interceptive for all of the beam and does not disturb the machine environment. In this paper, we present the theoretical aspects behind this technique for beam distribution measurement and some simulation results of the detector involved. First, a method to obtain parallel electron beam is introduced and a simulation code is developed. And then, EBP as a profile monitor for dense beam is simulated using fast scan method under various target beam profile, such as KV distribution, waterbag distribution, parabolic distribution, Gaussian distribution and halo distribution. Profile reconstruction from the deflected electron beam trajectory...

  14. Observation of high deflection efficiency and narrow energy loss distributions for 450 GeV protons channeled in a bent silicon crystal

    Science.gov (United States)

    Møller, S. P.; Worm, T.; Clément, M.; Doble, N.; Elsener, K.; Gatignon, L.; Grafström, P.; Uggerhøj, E.; Hage-Ali, M.; Siffert, P.

    1994-03-01

    A 450 GeV proton beam has been deflected by various angles from 1 to 11 mrad using planar channeling in a (111) silicon crystal which was mechanically bent to achieve the desired beam deflection. High deflection efficiencies of up to 50% have been measured, in good agreement with present theoretical estimates. It is shown that bent crystals are also a unique tool for measurements of energy loss and straggling of channeled particles, without any influence from random particles: Selecting protons which are deflected by increasing angles corresponds to decreasing the transverse energy at the crystal entrance. With this technique energy loss and straggling was measured for protons channeled in the wide and narrow (111) planes in silicon for the first time.

  15. Deflection of high energy protons by multiple volume reflections in a modified multi-strip silicon deflector

    CERN Document Server

    Scandale, W; Butcher, M.; Cerutti, F.; Gilardoni, S.; Lari, L.; Lechner, A.; Losito, R.; Masi, A.; Mereghetti, A.; Metral, E.; Mirarchi, D.; Montesano, S.; Redaelli, S.; Schoofs, P.; Smirnov, G.; Bagli, E.; Bandiera, L.; Baricordi, S.; Dalpiaz, P.; Guidi, V.; Mazzolari, A.; Vincenzi, D.; Claps, G.; Dabagov, S.; Hampai, D.; Murtas, F.; Cavoto, G.; Garattini, M.; Iacoangeli, F.; Ludovici, L.; Santacesaria, R.; Valente, P.; Galluccio, F.; Afonin, A.G.; Chesnokov, Yu.A.; Maisheev, V.A.; Sandomirskiy, Yu.E.; Yanovich, A.A.; Yazynin, I.A.; Kovalenko, A.D.; Taratin, A.M.; Gavrikov, Yu.A.; Ivanov, Yu.M.; Lapina, L.P.; Ferguson, W.; Fulcher, J.; Hall, G.; Pesaresi, M.; Raymond, M.; Previtali, V.

    2014-01-01

    The effect of multiple volume reflections in one crystal was observed in each of several bent silicon strips for 400 GeV/c protons. This considerably increased the particle deflections. Some particles were also deflected due to channeling in one of the subsequent strips. As a result, the incident beam was strongly spread because of opposite directions of the deflections. A modified multi-strip deflector produced by periodic grooves on the surface of a thick silicon plate was used for these measurements. This technique provides perfect mutual alignment between crystal strips. Such multi-strip deflector may be effective for collider beam halo collimation and a study is planned at the CERN SPS circulating beam.

  16. Measurement of deflection on germanium and gold prisms using 1.7 MeV laser Compton scattering γ-rays

    Science.gov (United States)

    Kawasaki, T.; Naito, S.; Sano, Y.; Hayakawa, T.; Shizuma, T.; Hajima, R.; Miyamoto, S.

    2017-09-01

    We measured the refractive index of germanium and gold prisms at 1.7 MeV to explore if there are refractive index enhancements to 6th power of atomic number due to high order nonlinear process of Delbrück scattering in quantum electrodynamics. We measured the deflection by prisms using imaging plates and laser Compton scattering γ-rays with linear and random polarization. We used crystal and polycrystalline prisms for Au. The measured upper limit of the refractive index, δ, for crystal Ge, crystal Au, or polycrystal Au prisms is 4.0 ×10-8, 2.9 ×10-7, or 2.4 ×10-7. We could not find any signature for high order nonlinear process. This result does not support the hypothesis suggested by Habs et al. (2012) [3].

  17. Beam-Beam Scans Within a Linear Collider Bunch-Train Crossing

    Energy Technology Data Exchange (ETDEWEB)

    Smith, S.R.; /SLAC

    2006-02-22

    Beam-beam deflection scans provide important beam diagnostics at the interaction point of a linear collider. Beam properties such as spot sizes, alignment, and waists are measured by sweeping one beam across the other. Proposed linear colliders use trains of bunches; if beam-beam scans can be done within the time of a bunch-train crossing rather than integrating over the bunch train, the acquisition rate of diagnostic information can be increased and the sensitivity of the scan to pulse-to-pulse jitter and slow drifts reduced. The existence of intra-train deflection feedback provides most of the hardware needed to implement intra-train beam-beam scans for diagnostic purposes. A conceptual design is presented for such beam-beam scans at the Next Linear Collider (NLC).

  18. 华盟售楼部钢梁挠度过大的分析与加固%On analysis and consolidation of excessive deflection of steel beam of Huameng House Selling Office

    Institute of Scientific and Technical Information of China (English)

    陈伟松; 陈春红; 刘若瀚

    2012-01-01

    According to the factual engineering examples,the paper analyzes the reasons for the recessive deflection of a 15 m steel beam,selects the consolidation method by enlarging the cross-section by comparison,illustrates the implementation schemes and the construction sequence in the section enlargement method,and proves by the practice that the consolidation method is easy to undertake and have better effect.%通过具体工程实例,对一根15 m跨钢梁挠度过大的原因展开了分析,经比较选择增大截面的加固方法,在此具体阐述了增大截面法的实施方案及施工顺序,实践证明,该加固方法简单易行,效果良好。

  19. AIDA: Asteroid Impact & Deflection Assessment

    Science.gov (United States)

    Cheng, A. F.; Galvez, A.; Carnelli, I.; Michel, P.; Rivkin, A.; Reed, C.

    2012-12-01

    To protect the Earth from a hazardous asteroid impact, various mitigation methods have been proposed, including deflection of the asteroid by a spacecraft impact. AIDA, consisting of two mission elements, the Double Asteroid Redirection Test (DART) and the Asteroid Impact Monitoring (AIM) mission, is a demonstration of asteroid deflection. To date, there has been no such demonstration, and there is major uncertainty in the result of a spacecraft impact onto an asteroid, that is, the amount of deflection produced by a given momentum input from the impact. This uncertainty is in part due to unknown physical properties of the asteroid surface, such as porosity and strength, and in part due to poorly understood impact physics such that the momentum carried off by ejecta is highly uncertain. A first mission to demonstrate asteroid deflection would not only be a major step towards gaining the capability to mitigate an asteroid hazard, but in addition it would return unique information on an asteroid's strength, other surface properties, and internal structure. This information return would be highly relevant to future human exploration of asteroids. We report initial results of the AIDA joint mission concept study undertaken by the Johns Hopkins Applied Physics Laboratory and ESA with support from NASA centers including Goddard, Johnson and Jet Propulsion Laboratory. For AIDA, the DART spacecraft impactor study is coordinated with an ESA study of the AIM mission, which would rendezvous with the same asteroid to measure effects of the impact. Unlike the previous Don Quijote mission study performed by ESA in 2005-2007, DART envisions an impactor spacecraft to intercept the secondary member of a binary near-Earth asteroid. DART includes ground-based observations to measure the deflection independently of the rendezvous spacecraft observations from AIM, which also measures deflection and provides detailed characterization of the target asteroid. The joint mission AIDA

  20. Linac4 low energy beam measurements with negative hydrogen ions.

    Science.gov (United States)

    Scrivens, R; Bellodi, G; Crettiez, O; Dimov, V; Gerard, D; Granemann Souza, E; Guida, R; Hansen, J; Lallement, J-B; Lettry, J; Lombardi, A; Midttun, Ø; Pasquino, C; Raich, U; Riffaud, B; Roncarolo, F; Valerio-Lizarraga, C A; Wallner, J; Yarmohammadi Satri, M; Zickler, T

    2014-02-01

    Linac4, a 160 MeV normal-conducting H(-) linear accelerator, is the first step in the upgrade of the beam intensity available from the LHC proton injectors at CERN. The Linac4 Low Energy Beam Transport (LEBT) line from the pulsed 2 MHz RF driven ion source, to the 352 MHz RFQ (Radiofrequency Quadrupole) has been built and installed at a test stand, and has been used to transport and match to the RFQ a pulsed 14 mA H(-) beam at 45 keV. A temporary slit-and-grid emittance measurement system has been put in place to characterize the beam delivered to the RFQ. In this paper a description of the LEBT and its beam diagnostics is given, and the results of beam emittance measurements and beam transmission measurements through the RFQ are compared with the expectation from simulations.

  1. Linac4 Low Energy Beam Measurements with Negative Hydrogen

    CERN Document Server

    Scrivens, R; Crettiez, O; Dimov, V; Gerard, D; Granemann Souza, E; Guida, R; Hansen, J; Lallement, J B; Lettry, J; Lombardi, A; Midttun, O; Pasquino, C; Raich, U; Riffaud, B; Roncarolo, F; Valerio-Lizarraga, C A; Wallner, J; Yarmohammadi Satri, M; Zickler, T

    2014-01-01

    Linac4, a 160 MeV normal-conducting H- linear accelerator, is the first step in the upgrade of the beam intensity available from the LHC proton injectors at CERN. The Linac4 Low Energy Beam Transport (LEBT) line from the pulsed 2 MHz RF driven ion source, to the 352 MHz RFQ has been built and installed at a test stand, and has been used to transport and match to the RFQ a pulsed 14 mA H- beam at 45 keV. A temporary slit-and-grid emittance measurement system has been put in place to characterize the beam delivered to the RFQ. In this paper a description of the LEBT and its beam diagnostics is given, and the results of beam emittance measurements and beam transmission measurements through the RFQ are compared with the expectation from simulations.

  2. Linac4 low energy beam measurements with negative hydrogen ions

    Energy Technology Data Exchange (ETDEWEB)

    Scrivens, R., E-mail: richard.scrivens@cern.ch; Bellodi, G.; Crettiez, O.; Dimov, V.; Gerard, D.; Granemann Souza, E.; Guida, R.; Hansen, J.; Lallement, J.-B.; Lettry, J.; Lombardi, A.; Midttun, Ø.; Pasquino, C.; Raich, U.; Riffaud, B.; Roncarolo, F.; Valerio-Lizarraga, C. A.; Wallner, J.; Yarmohammadi Satri, M.; Zickler, T. [CERN, 1211 Geneva 23 (Switzerland)

    2014-02-15

    Linac4, a 160 MeV normal-conducting H{sup −} linear accelerator, is the first step in the upgrade of the beam intensity available from the LHC proton injectors at CERN. The Linac4 Low Energy Beam Transport (LEBT) line from the pulsed 2 MHz RF driven ion source, to the 352 MHz RFQ (Radiofrequency Quadrupole) has been built and installed at a test stand, and has been used to transport and match to the RFQ a pulsed 14 mA H{sup −} beam at 45 keV. A temporary slit-and-grid emittance measurement system has been put in place to characterize the beam delivered to the RFQ. In this paper a description of the LEBT and its beam diagnostics is given, and the results of beam emittance measurements and beam transmission measurements through the RFQ are compared with the expectation from simulations.

  3. LHC Beam Instrumentation: Beam Loss and Tune Measurements (3/3)

    CERN Document Server

    CERN. Geneva

    2014-01-01

    The LHC is equipped with a full suite of sophisticated beam instrumentation which has been essential for rapid commissioning, the safe increase in total stored beam power and the understanding of machine optics and accelerator physics phenomena. These lectures will introduce these systems and comment on their contributions to the various stages of beam operation. They will include details on: the beam position system and its use for real-time global orbit feedback; the beam loss system and its role in machine protection; total and bunch by bunch intensity measurements; tune measurement and feedback; diagnostics for transverse beam size measurements, abort gap monitoring and longitudinal density measurements. Issues and problems encountered along the way will also be discussed together with the prospect for future upgrades.

  4. LHC Beam Instrumentation: Beam Position and Intensity Measurements (1/3)

    CERN Document Server

    CERN. Geneva

    2014-01-01

    The LHC is equipped with a full suite of sophisticated beam instrumentation which has been essential for rapid commissioning, the safe increase in total stored beam power and the understanding of machine optics and accelerator physics phenomena. These lectures will introduce these systems and comment on their contributions to the various stages of beam operation. They will include details on: the beam position system and its use for real-time global orbit feedback; the beam loss system and its role in machine protection; total and bunch by bunch intensity measurements; tune measurement and feedback; diagnostics for transverse beam size measurements, abort gap monitoring and longitudinal density measurements. Issues and problems encountered along the way will also be discussed together with the prospect for future upgrades.

  5. rf breakdown measurements in electron beam driven 200 GHz copper and copper-silver accelerating structures

    Science.gov (United States)

    Dal Forno, Massimo; Dolgashev, Valery; Bowden, Gordon; Clarke, Christine; Hogan, Mark; McCormick, Doug; Novokhatski, Alexander; O'Shea, Brendan; Spataro, Bruno; Weathersby, Stephen; Tantawi, Sami G.

    2016-11-01

    This paper explores the physics of vacuum rf breakdowns in subterahertz high-gradient traveling-wave accelerating structures. We present the experimental results of rf tests of 200 GHz metallic accelerating structures, made of copper and copper-silver. These experiments were carried out at the Facility for Advanced Accelerator Experimental Tests (FACET) at the SLAC National Accelerator Laboratory. The rf fields were excited by the FACET ultrarelativistic electron beam. The traveling-wave structure is an open geometry, 10 cm long, composed of two halves separated by a gap. The rf frequency of the fundamental accelerating mode depends on the gap size and can be changed from 160 to 235 GHz. When the beam travels off axis, a deflecting field is induced in addition to the longitudinal field. We measure the deflecting forces by observing the displacement of the electron bunch and use this measurement to verify the expected accelerating gradient. Furthermore, we present the first quantitative measurement of rf breakdown rates in 200 GHz metallic accelerating structures. The breakdown rate of the copper structure is 10-2 per pulse, with a peak surface electric field of 500 MV /m and a rf pulse length of 0.3 ns, which at a relatively large gap of 1.5 mm, or one wavelength, corresponds to an accelerating gradient of 56 MV /m . For the same breakdown rate, the copper-silver structure has a peak electric field of 320 MV /m at a pulse length of 0.5 ns. For a gap of 1.1 mm, or 0.74 wavelengths, this corresponds to an accelerating gradient of 50 MV /m .

  6. Beam induced vacuum measurement error in BEPC II

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    When the beam in BEPCII storage ring aborts suddenly, the measured pressure of cold cathode gauges and ion pumps will drop suddenly and decrease to the base pressure gradually. This shows that there is a beam induced positive error in the pressure measurement during beam operation. The error is the difference between measured and real pressures. Right after the beam aborts, the error will disappear immediately and the measured pressure will then be equal to real pressure. For one gauge, we can fit a non-linear pressure-time curve with its measured pressure data 20 seconds after a sudden beam abortion. From this negative exponential decay pumping-down curve, real pressure at the time when the beam starts aborting is extrapolated. With the data of several sudden beam abortions we have got the errors of that gauge in different beam currents and found that the error is directly proportional to the beam current, as expected. And a linear data-fitting gives the proportion coefficient of the equation, which we derived to evaluate the real pressure all the time when the beam with varied currents is on.

  7. AEgIS experiment: Towards antihydrogen beam production for antimatter gravity measurements

    CERN Document Server

    Mariazzi, Sebastiano; Amsler, Claude; Ariga, Akitaka; Ariga, Tomoko; Belov, Alexandre S; Bonomi, Germano; Bräunig, Philippe; Brusa, Roberto S; Bremer, Johan; Cabaret, Louis; Canali, Carlo; Caravita, Ruggero; Castelli, Fabrizio; Cerchiari, Giovanni; Cialdi, Simone; Comparat, Daniel; Consolati, Giovanni; Dassa, Luca; Derking, Jan Hendrik; Di Domizio, Sergio; Di Noto, Lea; Doser, Michael; Dudarev, Alexey; Ereditato, Antonio; Ferragut, Rafael; Fontana, Andrea; Genova, Pablo; Giammarchi, Marco; Gligorova, Angela; Gninenko, Sergei N; Hogan, Stephen D; Haider, Stefan; Jordan, Elena; Jørgensen, Lars V; Kaltenbacher, Thomas; Kawada, Jiro; Kellerbauer, Alban; Kimura, Mitsuhiro; Knecht, Andreas; Krasnický, Daniel; Lagomarsino, Vittorio; Lehner, Sebastian; Malbrunot, Chloe; Matveev, Viktor A; Merkt, Frederic; Moia, Fabio; Nebbia, Giancarlo; Nédélec, Patrick; Oberthaler, Markus K; Pacifico, Nicola; Petráček, Vojtech; Pistillo, Ciro; Prelz, Francesco; Prevedelli, Marco; Regenfus, Christian; Riccardi, Cristina; Røhne, Ole; Rotondi, Alberto; Sandaker, Heidi; Scampoli, Paola; Storey, James; Subieta Vasquez, Martin A.; Spaček, Michal; Czech Technical U. in Prague - FNSPE - B\\oehova 7 - 11519 - Praha 1 - Czech Aff25 Testera, Gemma; Vaccarone, Renzo; Villa, Fabio; Widmann, Eberhard; Zavatarelli, Sandra; Zmeskal, Johann

    2014-01-01

    AEgIS (Antimatter Experiment: Gravity, Interferometry, Spectroscopy) is an experiment that aims to perform the first direct measurement of the gravitational acceleration g of antihydrogen in the Earth’s field. A cold antihydrogen beam will be produced by charge exchange reaction between cold antiprotons and positronium excited in Rydberg states. Rydberg positronium (with quantum number n between 20 and 30) will be produced by a two steps laser excitation. The antihydrogen beam, after being accelerated by Stark effect, will fly through the gratings of a moir ́ e deflectometer. The deflection of the horizontal beam due to its free fall will be measured by a position sensitive detector. It is estimated that the detection of about 10 3 antihydrogen atoms is required to determine the gravitational acceleration with a precision of 1%. In this report an overview of the AEgIS experiment is presented and its current status is described. Details on the production of slow positronium and its excitation with lasers ar...

  8. Application of photothermal deflection spectroscopy to electrochemical interfaces

    Energy Technology Data Exchange (ETDEWEB)

    Rudnicki, J.D.; McLarnon, F.R.; Cairns, E.J.

    1992-03-01

    This dissertation discusses the theory and practice of Photothermal Deflection Spectroscopy (PDS, which is also known as probe beam deflection spectroscopy, PBDS, probe deflection technique, and mirage effect spectroscopy) with respect to electrochemical systems. Much of the discussion is also relevant to non-electrochemical systems. PDS can measure the optical absorption spectrum of interfaces and concentration gradients in the electrolyte adjacent to the electrode. These measurements can be made on a wide variety of electrode surfaces and can be performed under dynamic conditions. The first three chapters discuss the theory of the phenomena that can be detected by PDS, and the equipment used in a PDS system. A secondary gradient technique'' is proposed, which places the probe beam on the back of an electrode. The results of a numerical model yield a method for determining the offset of the probe beam from the electrode surface based on the frequency response of the PDS signal. The origin and control of noise in the PDS signal are discussed. A majority of the signal noise appears to be acoustic in origin. The electrochemical oxidation of platinum is used to demonstrate that PDS has sub-monolayer sensitivity necessary to study interfacial chemistry. The results allow us to propose a two-reaction oxidation mechanism: the platinum is electrochemically oxidized to form platinum dihydroxide and dehydrated by a non-electrochemical second-order reaction. The final chapter discusses the relation of PDS to similar and competing techniques, and considers possibilities for the future of the technique.

  9. Beam position and phase measurements of microampere beams at the Michigan State University REA3 facility

    CERN Document Server

    Crisp, J; Durickovic, B; Kiupel, G; Krause, S; Leitner, D; Nash, S; Rodriguez, J A; Russo, T; Webber, R; Wittmer, W; Eddy, N; Briegel, C; Fellenz, B; Slimmer, D; Wendt, M

    2013-01-01

    A high power CW, heavy ion linac will be the driver accelerator for the Facility for Rare Isotope Beams (FRIB) being designed at Michigan State University (MSU). The linac requires a Beam Position Monitoring (BPM) system with better than 100 micron resolution at 100 microamperes beam current. A low beam current test of the candidate technology, button pick-ups and direct digital down-conversion signal processing, was conducted in the ReA3 re-accelerated beam facility at Michigan State University. The test is described. Beam position and phase measurement results, demonstrating ~250 micron and ~1.5 degree resolution in a 45 kHz bandwidth for a 1.0 microampere beam current, are reported.

  10. Creep functions of dental ceramics measured in a beam-bending viscometer.

    Science.gov (United States)

    DeHoff, Paul H; Anusavice, Kenneth J

    2004-03-01

    To characterize the high temperature viscoelastic properties of several dental ceramics by the determination of creep functions based on mid-span deflections measured in a beam-bending viscometer (BBV). Six groups of beam specimens (58 x 5.5 x 2.5 mm) were made from the following materials: (1) IPS Empress2 body--a glass veneer ceramic (E2V); (2) an experimental glass veneer (EXV); (3) Vita VMK 68 feldspathic body porcelain--a low-expansion body porcelain (VB); (4) Will-Ceram feldspathic body porcelain--a high-expansion body porcelain (WCB); (5) Vita feldspathic opaque porcelain--a medium-expansion opaque porcelain (VO); and (6) Will-Ceram feldspathic opaque porcelain--a high-expansion opaque porcelain (WCO). Midpoint deflections for each specimen were measured in a BBV under isothermal conditions at furnace temperatures ranging from 450 to 675 degrees C. Non-linear regression and linear regression analyses were used to determine creep functions and shear viscosities, respectively, for each material at each temperature. The shear viscosities of each group of dental ceramics exhibited bilinear Arrhenius behavior with the slope ratios (x) ranging from 0.19 for WCB to 0.71 for EXV. At the higher temperature ranges, activation energies ranged from 363 kJ/mol for VO to 386 kJ/mol for E2V. The viscoelastic properties of dental ceramics at high temperatures are important factors in understanding how residual stresses develop in all-ceramic and metal-ceramic dental restorations.

  11. Beam-Profile Instrumentation for a Beam-Halo Measurement Overall Description, Operation, and Beam Data

    CERN Document Server

    Gilpatrick, J D; Day, L; Kerstiens, D; Stettler, M; Valdiviez, R

    2001-01-01

    The halo experiment presently being conducted at the Low Energy Demonstration Accelerator (LEDA) at Los Alamos National Laboratory (LANL) has specific instruments that acquire horizontally and vertically projected particle-density beam distributions out to greater than 105:1 dynamic range. We measure the core of the distributions using traditional wire scanners, and the tails of the distribution using water-cooled graphite scraping devices. The wire scanner and halo scrapers are mounted on the same moving frame whose location is controlled with stepper motors. A sequence within the Experimental Physics and Industrial Control System (EPICS) software communicates with a National Instrument LabVIEW virtual instrument to control the movement and location of the scanner/scraper assembly. Secondary electrons from the wire scanner 33 μm carbon wire and protons impinging on the scraper are both detected with a lossy-integrator electronic circuit. Algorithms implemented within EPICS and in Research Systems Interactiv...

  12. Component mode synthesis and large deflection vibration of complex structures. Volume 3: Multiple-mode nonlinear free and forced vibrations of beams using finite element method

    Science.gov (United States)

    Mei, Chuh; Shen, Mo-How

    1987-01-01

    Multiple-mode nonlinear forced vibration of a beam was analyzed by the finite element method. Inplane (longitudinal) displacement and inertia (IDI) are considered in the formulation. By combining the finite element method and nonlinear theory, more realistic models of structural response are obtained more easily and faster.

  13. Luminosity measurement and beam condition monitoring at CMS

    Energy Technology Data Exchange (ETDEWEB)

    Leonard, Jessica Lynn [DESY, Zeuthen (Germany)

    2015-07-01

    The BRIL system of CMS consists of instrumentation to measure the luminosity online and offline, and to monitor the LHC beam conditions inside CMS. An accurate luminosity measurement is essential to the CMS physics program, and measurement of the beam background is necessary to ensure safe operation of CMS. In expectation of higher luminosity and denser proton bunch spacing during LHC Run II, many of the BRIL subsystems are being upgraded and others are being added to complement the existing measurements. The beam condition monitor (BCM) consists of several sets of diamond sensors used to measure online luminosity and beam background with a single-bunch-crossing resolution. The BCM also detects when beam conditions become unfavorable for CMS running and may trigger a beam abort to protect the detector. The beam halo monitor (BHM) uses quartz bars to measure the background of the incoming beams at larger radii. The pixel luminosity telescope (PLT) consists of telescopes of silicon sensors designed to provide a CMS online and offline luminosity measurement. In addition, the forward hadronic calorimeter (HF) will deliver an independent luminosity measurement, making the whole system robust and allowing for cross-checks of the systematics. Data from each of the subsystems will be collected and combined in the BRIL DAQ framework, which will publish it to CMS and LHC. The current status of installation and commissioning results for the BRIL subsystems are given.

  14. On the way to high dynamic range beam profile measurements

    Energy Technology Data Exchange (ETDEWEB)

    Egberts, Jan; Artikova, Sayyora [Max-Planck-Institut fuer Kernphysik (Germany); Welsch, Carsten [University of Liverpool (United Kingdom); Cockcroft Institute of Accelerator Science and Technology (United Kingdom)

    2009-07-01

    A thorough understanding of halo formation and its possible control is highly desirable for essentially all particle accelerators. Particles outside the beam core are not only lost for further experiments, they are also likely to hit the drift chamber and thereby activate the beam pipe, which makes work on the accelerator costly and time consuming. A well-established technique for transverse beam profile measurements is synchrotron radiation (SR) for high energy and high luminosity accelerators like the LHC or CTF3. At much lower beam energies, an alternative for transverse beam profile measurements based on the direct measurement of light is optical transition radiation (OTR) or the insertion of a luminescent screen. What applies for essentially all these light generation processes, is that the light intensity is over a wide range proportional to the particle density, which makes the optical analysis of such light an ideal tool for beam profile measurements. A particular challenge, however, is to distinguish the particles in the tail regions of the beam distribution from the much more intense beam core. In this contribution, we present results from laboratory measurements on two different devices that might form the technical base of a future beam halo monitor: the novel SpectraCam XDR camera system and a flexible masking technique based on a DMD micro mirror array.

  15. Measurement of beam energy spread in a space-charge dominated electron beam

    Directory of Open Access Journals (Sweden)

    Y. Cui

    2004-07-01

    Full Text Available Characterization of beam energy spread in a space-charge dominated beam is very important to understanding the physics of intense beams. It is believed that coupling between the transverse and longitudinal directions via Coulomb collisions will cause an increase of the beam longitudinal energy spread. At the University of Maryland, experiments have been carried out to study the energy evolution in such intense beams with a high-resolution retarding field energy analyzer. The temporal beam energy profile along the beam pulse has been characterized at the distance of 25 cm from the anode of a gridded thermionic electron gun. The mean energy of the pulsed beams including the head and tail is reported here. The measured rms energy spread is in good agreement with the predictions of the intrabeam scattering theory. As an application of the beam energy measurement, the input impedance between the cathode and the grid due to beam loading can be calculated and the impedance number is found to be a constant in the operation region of the gun.

  16. Beam diffusion measurements using collimator scans in the LHC

    CERN Document Server

    Valentino, Gianluca; Bruce, Roderik; Burkart, Florian; Previtali, Valentina; Redaelli, Stefano; Salvachua, Belen; Stancari, Giuliov; Valishev, Alexander

    2013-01-01

    The time evolution of beam losses during a collimator scan provides information on halo diffusion and population. This is an essential input for machine performance characterization and for the design of collimation systems. Beam halo measurements in the CERN Large Hadron Collider were conducted through collimator scrapings in a dedicated beam study for the first time at 4 TeV. Four scans were performed with two collimators, in the vertical plane for beam 1 and horizontally for beam 2, before and after bringing the beams into collisions. Inward and outward steps were performed. A diffusion model was used to interpret the observed loss rate evolution in response to the collimator steps. With this technique, diffusion coefficients were estimated as a function of betatron oscillation amplitude from approximately 3 to 7 standard deviations of the transverse beam distribution. A comparison of halo diffusion and core emittance growth rates is also presented.

  17. Theoretical analysis of some problems in the measurement of beam divergence angle for EAST neutral beam injector

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    Beam angular divergence is one of the indicators to evaluate the beam quality. Operating parameters of the beam extraction system could be adjusted to gain better beam quality following the measurement results, which will be helpful not only to study the transmission characteristics of the beam and the power distribution on the heat load components, but also to understand the real-time working condition of the ion source and beam extraction system. This study includes: (1) the theoretical analysis of beam extraction pulse duration for measurement of beam angular divergence; (2) the theoretical analysis of beam intensity distribution during beam transmission for Experimental Advanced Superconducting Tokomak (EAST) neutral beam injector. Those theoretical analyses could point the way to the measurement of beam divergence angle for EAST neutral beam injector.

  18. Beam Forming HF Radar Beam Pattern Measurements and Phase Offset Calibration Using a UAV

    Science.gov (United States)

    Cahl, D.; Voulgaris, G.

    2016-12-01

    It has been shown that measuring antenna patterns for direction finding radars improves surface current measurements. For beam forming radars, the beam pattern of the receive array is assumed to be similar to that derived using theoretical calculations. However, local environmental conditions may lead to deviations (i.e., larger sidelobes and beamwidth) from this idealized beam pattern. This becomes particularly important for wave measurements that are sensitive to interference from sidelobes. Common techniques for beam forming HF radar phase calibration include "cross calibration", using a secondary beam forming site as the signal source, or calibration using a ship. The former method is limited to only one direction; on straight coastlines this is often at a large angle from the radar bore site where the beam width and uncertainty in phase calibration might be large. The latter technique requires chartering a ship with an appropriate reflector or transmitter, or the identification of ships of opportunity. Recent advances in UAV technology combined with an easement of FAA restrictions (Part 107) allows phase calibrations and beam pattern measurements to be completed on an HF radar site using a small transmitter attached to a UAV. This presentation describes the use of a UAV and the development of a method for beam forming phase calibration and beam pattern measurements. This method uses the UAV as a moving signal source to provide true sidelobe and beamwidth measurements. Results are shown from a calibration carried out at a beam forming (WERA) radar site (8.3 MHz) located in Georgetown, SC and are compared with results from a cross calibration. Phase calibrations acquired by the UAV showed a dependence on azimuthal angle from the radar bore site. Also, the beam patterns obtained were found to be narrower than those derived using the stationary source method. The effect of the new phase values derived using this method on the accuracy of radial velocities will be

  19. 贝克曼梁法测试水泥砼路面弯沉及路面持荷能力评价%Backman Beam Method Test of Cement Concrete Pavement Deflection and Pavement Loading Capacity Evaluation

    Institute of Scientific and Technical Information of China (English)

    2013-01-01

    Backman beam method for detection of the cement concrete pavement is widely used at home and abroad, and it is the main method of cement concrete pavement strength of our survey, there are a lot of the joint of cement concrete pavement, in the long-term running effect and infiltration of rainwater ef-fect, very easy to cause the void beneath slab. According to the Backman beam method detection deflection data, this paper pr-oposes treatment scheme on the plate considering the road blo-ck bearing capacity, load transfer capability, and verifies.%  贝克曼梁法检测水泥混凝土路面板底脱空是国内外广泛使用的方法,也是我国水泥混凝土路面路面强度调查的主要方法,水泥混凝土路面有很多接缝,在长期行车作用及雨水渗入作用下,很容易造成板底脱空。本文根据贝克曼梁法检测的弯沉数据,在综合考虑路面板块承载能力、传荷能力的情况对板块提出了处理方案,并进行了实例验证。

  20. Measurements and simulations of focused beam for orthovoltage therapy

    Energy Technology Data Exchange (ETDEWEB)

    Abbas, Hassan, E-mail: Hassan.Abbas@Yale.Edu [Department of Therapeutic Radiology, Yale University School of Medicine, Yale-New Haven Hospital, New Haven, 344 Lane Street Hamden, Connecticut 06514 (United States); Mahato, Dip N., E-mail: dip.n.mahato@intel.com [Intel Corporation, Mail-Stop RA3-410, 2501 NW 229th Avenue, Hillsboro, Oregon 97124 (United States); Satti, Jahangir, E-mail: sattij@mail.amc.edu [Department of Radiation Oncology, Albany Medical Center, 43 New Scotland Avenue, Albany, New York 12208 (United States); MacDonald, C. A., E-mail: c.macdonald@albany.edu [Department of Physics, University at Albany, SUNY, 1400 Washington Avenue, Albany, New York 12222 (United States)

    2014-04-15

    Purpose: Megavoltage photon beams are typically used for therapy because of their skin-sparing effect. However, a focused low-energy x-ray beam would also be skin sparing, and would have a higher dose concentration at the focal spot. Such a beam can be produced with polycapillary optics. MCNP5 was used to model dose profiles for a scanned focused beam, using measured beam parameters. The potential of low energy focused x-ray beams for radiation therapy was assessed. Methods: A polycapillary optic was used to focus the x-ray beam from a tungsten source. The optic was characterized and measurements were performed at 50 kV. PMMA blocks of varying thicknesses were placed between optic and the focal spot to observe any variation in the focusing of the beam after passing through the tissue-equivalent material. The measured energy spectrum was used to model the focused beam in MCNP5. A source card (SDEF) in MCNP5 was used to simulate the converging x-ray beam. Dose calculations were performed inside a breast tissue phantom. Results: The measured focal spot size for the polycapillary optic was 0.2 mm with a depth of field of 5 mm. The measured focal spot remained unchanged through 40 mm of phantom thickness. The calculated depth dose curve inside the breast tissue showed a dose peak several centimeters below the skin with a sharp dose fall off around the focus. The percent dose falls below 10% within 5 mm of the focus. It was shown that rotating the optic during scanning would preserve the skin-sparing effect of the focused beam. Conclusions: Low energy focused x-ray beams could be used to irradiate tumors inside soft tissue within 5 cm of the surface.

  1. Measuring the electron beam energy in a magnetic bunch compressor

    Energy Technology Data Exchange (ETDEWEB)

    Hacker, Kirsten

    2010-09-15

    Within this thesis, work was carried out in and around the first bunch compressor chicane of the FLASH (Free-electron LASer in Hamburg) linear accelerator in which two distinct systems were developed for the measurement of an electron beams' position with sub-5 {mu}m precision over a 10 cm range. One of these two systems utilized RF techniques to measure the difference between the arrival-times of two broadband electrical pulses generated by the passage of the electron beam adjacent to a pickup antenna. The other system measured the arrival-times of the pulses from the pickup with an optical technique dependent on the delivery of laser pulses which are synchronized to the RF reference of the machine. The relative advantages and disadvantages of these two techniques are explored and compared to other available approaches to measure the same beam property, including a time-of-flight measurement with two beam arrival-time monitors and a synchrotron light monitor with two photomultiplier tubes. The electron beam position measurement is required as part of a measurement of the electron beam energy and could be used in an intra-bunch-train beam-based feedback system that would stabilize the amplitude of the accelerating field. By stabilizing the accelerating field amplitude, the arrival-time of the electron beam can be made more stable. By stabilizing the electron beam arrival-time relative to a stable reference, diagnostic, seeding, and beam-manipulation lasers can be synchronized to the beam. (orig.)

  2. Measurement of diagnostic neutral beam parameters on J-TEXT

    Science.gov (United States)

    Wang, J. R.; Cheng, Z. F.; Li, Z.; Li, Y.; Luo, J.; Zhang, X. L.; Zhuang, G.

    2016-11-01

    A Doppler frequency shift spectrum (DFSS) system composed of two spectrometers has been developed for the joint Texas experimental tokamak to measure diagnostic neutral beam parameters including the beam energy fractions, intensity distributions, and divergences. The beam energy fractions are derived from measurements of H-alpha (Hα) emission using collisional excitation cross sections. The beam intensity distributions are obtained using an 11-channel measurement with a reconstruction technique. The beam divergences are obtained from spectrum broadening and geometric calculations. The results of preliminary investigations indicate that the DFSS system works well and can be used to obtain all of these parameters simultaneously. According to the preliminary experiment, the one-third energy fraction has the largest proportion (about 45%) of the beam energy and the full energy fraction is about 10%. The beam diameter is about 8.1 cm at a distance of 2.04 m from the accelerator. The beam divergence angle is about 3.3°. The current beam parameters are insufficient for charge-exchange measurements.

  3. Beam Parameters Measurement Based On Tv Methods

    CERN Document Server

    Klimenkov, E; Milichenko, Yu; Voevodin, V

    2004-01-01

    The paper describes hardware and software used to control TV-cameras and to process TV-images of luminescent screens placed along the beam transfer lines. Industrial devices manually control the movements and focusing of the cameras. All devices are linked to PC via PCI interfaces with homemade drivers for Linux OS and provide both selection of camera and digitizing of video signal synchronized with beam. One part of software provides means to set initial parameters using PC consol. Thus an operator can choose contrast, brightness, some number of significant points on TV-image to calculate beam position and its size. Second part supports remote TV controls and data processing from Control Rooms of U-70 complex using set initial parameters. First experience and results of the method realization are discussed.

  4. Electron beam based transversal profile measurements of intense ion beams; Elektronenstrahl-Diagnostik zur Bestimmung vom transversalen Profil intensiver Ionenstrahlen

    Energy Technology Data Exchange (ETDEWEB)

    El Moussati, Said

    2014-11-03

    A non-invasive diagnostic method for the experimental determination of the transverse profile of an intense ion beam has been developed and investigated theoretically as well as experimentally within the framework of the present work. The method is based on the deflection of electrons when passing the electromagnetic field of an ion beam. To achieve this an electron beam is employed with a specifically prepared transversal profile. This distinguish this method from similar ones which use thin electron beams for scanning the electromagnetic field [Roy et al. 2005; Blockland10]. The diagnostic method presented in this work will be subsequently called ''Electron-Beam-Imaging'' (EBI). First of all the influence of the electromagnetic field of the ion beam on the electrons has been theoretically analyzed. It was found that the magnetic field causes only a shift of the electrons along the ion beam axis, while the electric field only causes a shift in a plane transverse to the ion beam. Moreover, in the non-relativistic case the magnetic force is significantly smaller than the Coulomb one and the electrons suffer due to the magnetic field just a shift and continue to move parallel to their initial trajectory. Under the influence of the electric field, the electrons move away from the ion beam axis, their resulting trajectory shows a specific angle compared to the original direction. This deflection angle practically depends just on the electric field of the ion beam. Thus the magnetic field has been neglected when analysing the experimental data. The theoretical model provides a relationship between the deflection angle of the electrons and the charge distribution in the cross section of the ion beam. The model however only can be applied for small deflection angles. This implies a relationship between the line-charge density of the ion beam and the initial kinetic energy of the electrons. Numerical investigations have been carried out to clarify the

  5. Generating and measuring nondiffracting vector Bessel beams

    CSIR Research Space (South Africa)

    Dudley, Angela L

    2013-09-01

    Full Text Available modulator and an azimuthally varying birefringent plate, known as a q-plate. We extend our control of both the geometric and dynamic phases to perform a polarization and modal decomposition on the vector field. We study both single-charged Bessel beams...

  6. Electron Beam Lifetime in SPEAR3: Measurement and Simulation

    Energy Technology Data Exchange (ETDEWEB)

    Corbett, J.; Huang, X.; Lee, M.; Lui, P.; /SLAC; Sayyar-Rodsari, B.; /Pavilon Tech., Austin

    2007-12-19

    In this paper we report on electron beam lifetime measurements as a function of scraper position, RF voltage and bunch fill pattern in SPEAR3. We then outline development of an empirical, macroscopic model using the beam-loss rate equation. By identifying the dependence of loss coefficients on accelerator and beam parameters, a numerically-integrating simulator can be constructed to compute beam decay with time. In a companion paper, the simulator is used to train a parametric, non-linear dynamics model for the system [1].

  7. Measuring the Orbital Angular Momentum of Electron Beams

    CERN Document Server

    Guzzinati, Giulio; Béché, Armand; Verbeeck, Jo

    2014-01-01

    The recent demonstration of electron vortex beams has opened up the new possibility of studying orbital angular momentum (OAM) in the interaction between electron beams and matter. To this aim, methods to analyze the OAM of an electron beam are fundamentally important and a necessary next step. We demonstrate the measurement of electron beam OAM through a variety of techniques. The use of forked holographic masks, diffraction from geometric apertures, diffraction from a knife-edge and the application of an astigmatic lens are all experimentally demonstrated. The viability and limitations of each are discussed with supporting numerical simulations.

  8. Compact Measurement Station for Low Energy Proton Beams

    CERN Document Server

    Yildiz, H.

    2017-01-01

    A compact, remote controlled, cost efficient diagnostic station has been developed to measure the charge, the profile and the emittance for low energy proton beams. It has been installed and tested in the proton beam line of the Project Prometheus at SANAEM of the Turkish Atomic Energy Authority.

  9. Laser Beam Caustic Measurement with Focal Spot Analyser

    DEFF Research Database (Denmark)

    Olsen, Flemming Ove; Gong, Hui; Bagger, Claus

    2005-01-01

    In industrial applications of high power CO2-lasers the caustic characteristics of the laser beam have great effects on the performance of the lasers. A welldefined high intense focused spot is essential for reliable production results. This paper presents a focal spot analyser that is developed...... for measuring the beam profiles of focused high power CO2-lasers....

  10. Beam Loss Patterns at the LHC Collimators Measurements & Simulations

    CERN Document Server

    Böhlen, Till Tobias

    2008-01-01

    The Beam Loss Monitoring (BLM) system of the Large Hadron Collider (LHC) detects particle losses of circulating beams and initiates an emergency extraction of the beam in case that the BLM thresholds are exceeded. This protection is required as energy deposition in the accelerator equipment due to secondary shower particles can reach critical levels; causing damage to the beam-line components and quenches of superconducting magnets. Robust and movable beam line elements, so-called collimators, are the aperture limitations of the LHC. Consequently, they are exposed to the excess of lost beam particles and their showers. Proton loss patterns at LHC collimators have to be determined to interpret the signal of the BLM detectors and to set adequate BLM thresholds for the protection of collimators and other equipment in case of unacceptably increased loss rates. The first part of this work investigates the agreement of BLM detector measurements with simulations for an LHC-like collimation setup. The setup consists ...

  11. Beta Beams for Precision Measurements of Neutrino Oscillation Parameters

    CERN Document Server

    Wildner, E; Hansen, C; De Melo Mendonca, T; Stora, T; Damjanovic, S; Payet, J; Chancé, A; Zorin, V; Izotov, I; Rasin, S; Sidorov, A; Skalyga, V; De Angelis, G; Prete, G; Cinausero, M; Kravchuk, V; Gramegna, F; Marchi, T; Collazuol, G; Mezzetto, M; Delbar, T; Loiselet, M; Keutgen, T; Mitrofanov, S; Burt, G; Dexter, A; Lamy, T; Latrasse, L; Marie-Jeanne, M; Sortais, P; Thuillier, T; Debray, F; Trophime, C; Hass, M; Hirsh, T; Berkovits, D; Stahl, A; Vardaci, E; Di Nitto, A; Brondi, A; La Rana, G; Moro, R; De Rosa, G; Palladino, V

    2012-01-01

    Neutrino oscillations have implications for the Standard Model of particle physics. The CERN Beta Beam has outstanding capabilities to contribute to precision measurements of the parameters governing neutrino oscillations. The FP7 collaboration EUROnu (2008-2012) is a design study that will review three facilities (Super-Beams, Beta Beams and Neutrino Factories) and perform a cost assessment that, coupled with the physics performance, will give means to the European research authorities to make decisions on future European neutrino oscillation facilities. ”Beta Beams” produce collimated pure electron (anti)neutrinos by accelerating beta active ions to high energies and having them decay in a storage ring. Using existing machines and infrastructure is an advantage for the cost evaluation; however, this choice is also constraining the Beta Beams. Recent work to make the Beta Beam facility a solid option will be described: production of Beta Beam isotopes, the 60 GHz pulsed ECR source development, integratio...

  12. Beam diagnostics measurements at 3 MeV of the LINAC4 H- beam at CERN

    CERN Document Server

    Zocca, F; Duraffourg, M; Focker, G J; Gerard, D; Kolad, B; Lenardon, F; Ludwig, M; Raich, U; Roncarolo, F; Sordet, M; Tan, J; Tassan-Viol, J; Vuitton, C; Feshenko, A

    2014-01-01

    As part of the CERN LHC injector chain upgrade, LINAC4 [1, 2] will accelerate H- ions to 160 MeV, replacing the old 50 MeV proton linac. The ion source, the Low Energy Beam Transfer (LEBT) line, the 3 MeV Radio Frequency Quadrupole and the Medium Energy Beam Transfer (MEBT) line hosting a chopper, have been commissioned in the LINAC4 tunnel. Diagnostic devices are installed in the LEBT and MEBT line and in a movable diagnostics test bench which is temporarily added to the MEBT exit. The paper gives an overview of all the instruments used, including beam current transformers, beam position monitors, wire scanners and wire grids for transverse profile measurements, a longitudinal bunch shape monitor and a slit-and-grid emittance meter. The instrumentation performance is discussed and the measurement results that allowed characterizing the 3 MeV beam in the LINAC4 tunnel are summarized.

  13. Surface effects on large deflection of nanowires

    Institute of Scientific and Technical Information of China (English)

    杨帆

    2015-01-01

    Surface effects play an important role in the mechanical behavior of nanosized structural elements owing to the increased ratio of surface area to volume. The surface effects on the large deflection of nanowires were considered. Both geometric nonlinearity in finite deformation and surface effects at nanoscale were taken into account to analyze the bending of nanowires subjected to a concentrated force. For simply supported beams and clamped-clamped beams, the influence of surface effects and geometric nonlinearity were discussed in detail. It is found that both surface effects and geometric nonlinearity tend to decrease the deflection of bending nanowires and thus increase the effective elastic modulus of nanowires. Surface effects yield the size dependent behavior of nanowires.

  14. Innovative real-time and non-destructive method of beam profile measurement under large beam current irradiation for BNCT

    Energy Technology Data Exchange (ETDEWEB)

    Takada, M., E-mail: m_takada@nirs.go.jp [National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Kamada, S.; Suda, M. [National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Fujii, R.; Nakamura, M. [Cancer Intelligence Care Systems, Inc., 3-5-7 Ariake, Koto-ku, Tokyo 135-0063 (Japan); Hoshi, M. [Research Institute for Radiation Biology and Medicine, Hiroshima University, 1-2-3 kasumi, Minami-ku, Hiroshima 734-8553 (Japan); Sato, H. [Ibaraki Prefectural University of Health Sciences, 4669-2, Ami Ami-Cho, Inashiki-gun, Ibaraki 300-0394 (Japan); Endo, S. [Quantum Energy Applications, Graduate School of Engineering, Hiroshima University, 1-4-1 Kagamiyama, Higashi-Hiroshima 739-8527 (Japan); Hamano, T. [National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Arai, S.; Higashimata, A. [Sanki Industry Co., 318-6, Sannoh, Inage-ku, Chiba 263-0002 (Japan)

    2012-10-11

    We developed a real-time and non-destructive method of beam profile measurement on a target under large beam current irradiation, and without any complex radiation detectors or electrical circuits. We measured the beam profiles on a target by observing the target temperature using an infrared-radiation thermometer camera. The target temperatures were increased and decreased quickly by starting and stopping the beam irradiation within 1 s in response speed. Our method could trace beam movements rapidly. The beam size and position were calibrated by measuring O-ring heat on the target. Our method has the potential to measure beam profiles at beam current over 1 mA for proton and deuteron with the energy around 3 MeV and allows accelerator operators to adjust the beam location during beam irradiation experiments without decreasing the beam current.

  15. Production, Characterization, and Measurement of H(D) Beams on the ORNL Merged-Beams Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, J. D. [University of Toledo, Toledo, OH; Kvale, Thomas Jay [University of Toledo, Toledo, OH; Strasser, S. M. [Albion College; Seely, D. G. [Albion College; Havener, Charles C [ORNL

    2009-01-01

    Total cross section measurements of electron capture processes are being studied for low-energy, Aq++H(D) collisions using the Ion-Atom Merged-Beams apparatus at the Multicharged Ion Research Facility (MIRF) at Oak Ridge National Laboratory (ORNL). On this apparatus, a modified Faraday cup detector is used to measure the intensity of the neutral beam. The conversion of the measured electrical current to the true neutral particle beam current is necessary to accurately determine the true cross section values. Inherent in this conversion process is the number of secondary electrons (gamma) emitted from the surface of the detector upon impact of an atom. The method employed to determine gamma and its role in the absolute electron capture measurements at ORNL-MIRF are presented. With a recent upgrade to the apparatus, the neutral beam H(D) production technique has been improved and is discussed in detail in this paper.

  16. Analysis Of Factors Affecting Gravity-Induced Deflection For Large And Thin Wafers In Flatness Measurement Using Three-Point-Support Method

    Directory of Open Access Journals (Sweden)

    Liu Haijun

    2015-12-01

    Full Text Available Accurate flatness measurement of silicon wafers is affected greatly by the gravity-induced deflection (GID of the wafers, especially for large and thin wafers. The three-point-support method is a preferred method for the measurement, in which the GID uniquely determined by the positions of the supports could be calculated and subtracted. The accurate calculation of GID is affected by the initial stress of the wafer and the positioning errors of the supports. In this paper, a finite element model (FEM including the effect of initial stress was developed to calculate GID. The influence of the initial stress of the wafer on GID calculation was investigated and verified by experiment. A systematic study of the effects of positioning errors of the support ball and the wafer on GID calculation was conducted. The results showed that the effect of the initial stress could not be neglected for ground wafers. The wafer positioning error and the circumferential error of the support were the most influential factors while the effect of the vertical positioning error was negligible in GID calculation.

  17. Scale factor correction for Gaussian beam truncation in second moment beam radius measurements

    Science.gov (United States)

    Hofer, Lucas R.; Dragone, Rocco V.; MacGregor, Andrew D.

    2017-04-01

    Charged-couple devices (CCD) and complementary metal oxide semiconductor (CMOS) image sensors, in conjunction with the second moment radius analysis method, are effective tools for determining the radius of a laser beam. However, the second moment method heavily weights sensor noise, which must be dealt with using a thresholding algorithm and a software aperture. While these noise reduction methods lower the random error due to noise, they simultaneously generate systematic error by truncating the Gaussian beam's edges. A scale factor that is invariant to beam ellipticity and corrects for the truncation of the Gaussian beam due to thresholding and the software aperture has been derived. In particular, simulations showed an order of magnitude reduction in measured beam radius error when using the scale factor-irrespective of beam ellipticity-and further testing with real beam data demonstrated that radii corrected by the scale factor are independent of the noise reduction parameters. Thus, through use of the scale factor, the accuracy of beam radius measurements made with a CCD or CMOS sensor and the second moment are significantly improved.

  18. Beam Optics Measurements Through Turn by Turn Beam Position Data in the SLS

    CERN Document Server

    Zisopoulos, P; Streun, A; Ziemann, v

    2013-01-01

    Refined Fourier analysis of turn-by-turn (TBT) transverse position data measurements can be used for determining several beam properties of a ring, such as transverse tunes, optics functions, phases, chromatic properties and coupling. In particular, the Numerical Analysis of Fundamental Frequencies (NAFF) algorithm is used to analyse TBT data from the Swiss Light Source (SLS) storage ring in order to estimate on and off-momentum beam characteristics. Of particular interest is the potential of using the full position information within one turn in order to measure beam optics properties.

  19. Beam Emittance Measurement for PLS-II Linac

    CERN Document Server

    Lee, Byung-Joon; Park, Chong do; Chunjarean, SomJai; Kim, Changbum

    2016-01-01

    The PLS-II has a 100 MeV pre-injector for the 3 GeV Linac. A thermionic gun produces electron charge of 200 pC with a bunch duration of 500 ps by a 250 ps triggering pulser. At the pre-injector, one of the most important beam parameters to identify the beam quality is a transverse emittance of electron bunches. Therefore we measure the beam emittance and twiss functions at 100 MeV in order to match the beam optics to beam transport line and go through it to the storage ring. To get the transverse emittance measurement, well-known technique, quadrupole scan, is used at the pre-injector. The emittance were 0.591 mm-mrad in horizontal and 0.774 mm-mrad in vertical direction.

  20. Viscoelastic Modelling of Road Deflections for use with the Traffic Speed Deflectometer

    DEFF Research Database (Denmark)

    Pedersen, Louis

    This Ph.D. study is at its core about how asphalt and road structures responds to dynamic loads. Existing models for the deflections under a moving load using beam equations are revisited and it is concluded they leave room for improvement for the particular setup and problem at hand. Then a diff......This Ph.D. study is at its core about how asphalt and road structures responds to dynamic loads. Existing models for the deflections under a moving load using beam equations are revisited and it is concluded they leave room for improvement for the particular setup and problem at hand...... of a generalized Maxwell model. Validations by comparison to ViscoRoute simulations are also made. This justifies the use of the Laplace FEM for generating simulated data using a Huet-Sayegh model for the visco-elastic behaviour of asphalt. These simulated data, along with measured data, are then used to suggest...

  1. Measurements of Terahertz Generation in a Metallic, Corrugated Beam Pipe

    CERN Document Server

    Bane, K L F; Fedurin, M; Kusche, K; Swinson, C; Xiang, D

    2016-01-01

    A method for producing narrow-band THz radiation proposes passing an ultra-relativistic beam through a metallic pipe with small periodic corrugations. We present results of a measurement of such an arrangement at Brookhaven's Accelerator Test Facility (ATF). Our pipe was copper and was 5 cm long; the aperture was cylindrically symmetric, with a 1 mm (radius) bore and a corrugation depth (peak-to-peak) of 60 um. In the experiment we measured both the effect on the beam of the structure wakefield and the spectral properties of the radiation excited by the beam. We began by injecting a relatively long beam compared to the wavelength of the radiation to excite the structure, and then used a downstream spectrometer to infer the radiation wavelength. This was followed by injecting a shorter bunch, and then using an interferometer (also downstream of the corrugated pipe) to measure the spectrum of the induced THz radiation.

  2. Measurements of Beam Ion Loss from the Compact Helical System

    Energy Technology Data Exchange (ETDEWEB)

    D. S. Darrow, M. Isobe, Takashi Kondo, M. Sasao, and the CHS Group National Institute for Fusion Science, Toki, Gifu, Japan

    2010-02-03

    Beam ion loss from the Compact Helical System (CHS) has been measured with a scintillator-type probe. The total loss to the probe, and the pitch angle and gyroradius distributions of that loss, have been measured as various plasma parameters were scanned. Three classes of beam ion loss were observed at the probe position: passing ions with pitch angles within 10o of those of transition orbits, ions on transition orbits, and ions on trapped orbits, typically 15o or more from transition orbits. Some orbit calculations in this geometry have been performed in order to understand the characteristics of the loss. Simulation of the detector signal based upon the following of orbits from realistic beam deposition profiles is not able to reproduce the pitch angle distribution of the losses measured. Consequently it is inferred that internal plasma processes, whether magnetohydrodynamic modes, radial electric fields, or plasma turbulence, move previously confined beam ions to transition orbits, resulting in their loss.

  3. Employing Beam-Gas Interaction Vertices for Transverse Profile Measurements

    CERN Document Server

    Rihl, Mariana; Baglin, Vincent; Barschel, Colin; Bay, Aurelio; Blanc, Frederic; Bravin, Enrico; Bregliozzi, Giuseppe; Chritin, Nicolas; Dehning, Bernd; Ferro-Luzzi, Massimiliano; Gaspar, Clara; Gianì, Sebastiana; Giovannozzi, Massimo; Greim, Roman; Haefeli, Guido; Hopchev, Plamen; Jacobsson, Richard; Jensen, Lars; Jones, Owain Rhodri; Jurado, Nicolas; Kain, Verena; Karpinski, Waclaw; Kirn, Thomas; Kuhn, Maria; Luthi, Berengere; Magagnin, Paolo; Matev, Rosen; Nakada, Tatsuya; Neufeld, Niko; Panman, Jaap; Rakotomiaramanana, Barinjaka; Salustino Guimaraes, Valdir; Salvant, Benoit; Schael, Stefan; Schneider, Olivier; Schwering, Georg; Tobin, Mark; Veness, Raymond; Veyrat, Quentin; Vlachos, Sotiris; Wlochal, Michael; Xu, Zhirui; von Dratzig, Arndt

    2016-01-01

    Interactions of high-energy beam particles with residual gas offer a unique opportunity to measure the beam profile in a non-intrusive fashion. Such a method was successfully pioneered* at the LHCb experiment using a silicon microstrip vertex detector. During the recent Large Hadron Collider shutdown at CERN, a demonstrator Beam-Gas Vertexing system based on eight scintillating-fibre modules was designed**, constructed and installed on Ring 2 to be operated as a pure beam diagnostics device. The detector signals are read out and collected with LHCb-type front-end electronics and a DAQ system consisting of a CPU farm. Tracks and vertices will be reconstructed to obtain a beam profile in real time. Here, first commissioning results are reported. The advantages and potential for future applications of this technique are discussed.

  4. Transverse Schottky and beam transfer function measurements in space charge affected coasting ion beams

    Directory of Open Access Journals (Sweden)

    Stefan Paret

    2010-02-01

    Full Text Available Transverse Schottky spectra and beam transfer functions (BTFs of coasting ion beams were measured in the heavy ion synchrotron SIS-18 in order to study the impact of space charge on the transverse beam dynamics. The particle number in the beam was varied to investigate the intensity dependence of the space-charge effect. No cooling was applied to the beams throughout the experiment. The expected deformation of the Schottky spectra and BTFs is observed. An analytic model with linear space charge is employed to describe the deformed Schottky and BTF signals. In this model, the incoherent space-charge force and the coherent forces due to impedances are treated separately. Using the model, the space-charge induced tune shift is evaluated both from the position and the form of the signals. The data are well described by the model, only in the high-intensity BTFs deviations are observed. The stability diagrams are shifted according to the space-charge parameter obtained from the BTFs. In addition, the tune shift is estimated by virtue of measured beam profiles and particle numbers. The estimated tune shift is of the same order of magnitude but smaller than the measured one. Possible explanations for deviations between the measurements, the model, and the estimation are discussed.

  5. Nonlinear Strain Measures, Shape Functions and Beam Elements for Dynamics of Flexible Beams

    Energy Technology Data Exchange (ETDEWEB)

    Sharf, I. [University of Victoria, Department of Mechanical Engineering (Canada)

    1999-05-15

    In this paper, we examine several aspects of the development of an explicit geometrically nonlinear beam element. These are: (i) linearization of the displacement field; (ii) the effect of a commonly adopted approximation for the nonlinear Lagrangian strain; and (iii) use of different-order shape functions for discretization. The issue of rigid-body check for a nonlinear beam element is also considered. An approximate check is introduced for an element based on an (approximate) intermediate strain measure. Several numerical examples are presented to support the analysis. The paper concludes with a discussion on the use of explicit nonlinear beam elements for multibody dynamics simulation.

  6. Simulation and Measurements of Beam Losses on LHC Collimators During Beam Abort Failures

    CERN Document Server

    Lari, L; Bruce, R; Goddard, B; Redaelli, S; Salvachua, B; Valentino, G; Faus-Golfe, A

    2013-01-01

    One of the main purposes of tracking simulations for collimation studies is to produce loss maps along the LHC ring, in order to identify the level of local beam losses during nominal and abnormal operation scenarios. The SixTrack program is the standard tracking tool used at CERN to perform these studies. Recently, it was expanded in order to evaluate the proton load on different collimators in case of fast beam failures. Simulations are compared with beam measurements at 4 TeV. Combined failures are assumed which provide worst-case scenarios of the load on tungsten tertiary collimators.

  7. Laser alignment measurement model with double beam

    Science.gov (United States)

    Mo, Changtao; Zhang, Lili; Hou, Xianglin; Wang, Ming; Lv, Jia; Du, Xin; He, Ping

    2012-10-01

    Double LD-Double PSD schedule.employ a symmetric structure and there are a laser and a PSD receiver on each axis. The Double LD-Double PSD is used, and the rectangular coordinate system is set up by use of the relationship of arbitrary two points coordinates, and then the parameter formula is deduced by the knowledge of solid geometry. Using the data acquisition system and the data processing model of laser alignment meter with double laser beam and two detector , basing on the installation parameter of the computer, we can have the state parameter between the two shafts by more complicated calculation and correction. The correcting data of the four under chassis of the adjusted apparatus moving on the level and the vertical plane can be calculated using the computer. This will instruct us to move the apparatus to align the shafts.

  8. Characterization of Detectors for Beam Loss Measurements

    CERN Document Server

    Panniello, M; Finocchiaro, P; Mallows, S; Welsch, C P

    2012-01-01

    Silicon Photomultipliers (SiPMs) are a good candidate for use as beam loss detectors in an accelerator due to their insensitivity to magnetic fields, compactness and relatively low voltage working regime. Furthermore, when used in large numbers, they are significantly cheaper to be mass-produced than more conventional detectors, such as Ionization Chambers. To be able to evaluate the application potential of SiPMs in an accelerator, it is necessary to quantify their fundamental parameters as light detectors, as well as in combination with an optical fiber used for signal generation. In this contribution an experimental and analytical study to determine the time resolution, light sensitivity and dynamic range of a Cherenkov light detector, based on SiPMs, is presented.

  9. A Bridge Deflection Monitoring System Based on CCD

    Directory of Open Access Journals (Sweden)

    Baohua Shan

    2016-01-01

    Full Text Available For long-term monitoring of the midspan deflection of Songjiazhuang cloverleaf junction on 309 national roads in Zibo city, this paper proposes Zhang’s calibration-based DIC deflection monitoring method. CCD cameras are used to track the change of targets’ position, Zhang’s calibration algorithm is introduced to acquire the intrinsic and extrinsic parameters of CCD cameras, and the DIC method is combined with Zhang’s calibration algorithm to measure bridge deflection. The comparative test between Zhang’s calibration and scale calibration is conducted in lab, and experimental results indicate that the proposed method has higher precision. According to the deflection monitoring scheme, the deflection monitoring software for Songjiazhuang cloverleaf junction is developed by MATLAB, and a 4-channel CCD deflection monitoring system for Songjiazhuang cloverleaf junction is integrated in this paper. This deflection monitoring system includes functions such as image preview, simultaneous collection, camera calibration, deflection display, and data storage. In situ deflection curves show a consistent trend; this suggests that the proposed method is reliable and is suitable for the long-term monitoring of bridge deflection.

  10. Measurement and simulation of the TRR BNCT beam parameters

    Science.gov (United States)

    Bavarnegin, Elham; Sadremomtaz, Alireza; Khalafi, Hossein; Kasesaz, Yaser; Golshanian, Mohadeseh; Ghods, Hossein; Ezzati, Arsalan; Keyvani, Mehdi; Haddadi, Mohammad

    2016-09-01

    Recently, the configuration of the Tehran Research Reactor (TRR) thermal column has been modified and a proper thermal neutron beam for preclinical Boron Neutron Capture Therapy (BNCT) has been obtained. In this study, simulations and experimental measurements have been carried out to identify the BNCT beam parameters including the beam uniformity, the distribution of the thermal neutron dose, boron dose, gamma dose in a phantom and also the Therapeutic Gain (TG). To do this, the entire TRR structure including the reactor core, pool, the thermal column and beam tubes have been modeled using MCNPX Monte Carlo code. To measure in-phantom dose distribution a special head phantom has been constructed and foil activation techniques and TLD700 dosimeter have been used. The results show that there is enough uniformity in TRR thermal BNCT beam. TG parameter has the maximum value of 5.7 at the depth of 1 cm from the surface of the phantom, confirming that TRR thermal neutron beam has potential for being used in treatment of superficial brain tumors. For the purpose of a clinical trial, more modifications need to be done at the reactor, as, for example design, and construction of a treatment room at the beam exit which is our plan for future. To date, this beam is usable for biological studies and animal trials. There is a relatively good agreement between simulation and measurement especially within a diameter of 10 cm which is the dimension of usual BNCT beam ports. This relatively good agreement enables a more precise prediction of the irradiation conditions needed for future experiments.

  11. Measurement and simulation of the TRR BNCT beam parameters

    Energy Technology Data Exchange (ETDEWEB)

    Bavarnegin, Elham [Nuclear Science and Technology Research Institute (NSTRI), Tehran (Iran, Islamic Republic of); Department of Physics, University of Guilan, Rasht (Iran, Islamic Republic of); Sadremomtaz, Alireza [Department of Physics, University of Guilan, Rasht (Iran, Islamic Republic of); Khalafi, Hossein [Nuclear Science and Technology Research Institute (NSTRI), Tehran (Iran, Islamic Republic of); Kasesaz, Yaser, E-mail: ykasesaz@aeoi.org.ir [Nuclear Science and Technology Research Institute (NSTRI), Tehran (Iran, Islamic Republic of); Golshanian, Mohadeseh; Ghods, Hossein; Ezzati, Arsalan; Keyvani, Mehdi; Haddadi, Mohammad [Nuclear Science and Technology Research Institute (NSTRI), Tehran (Iran, Islamic Republic of)

    2016-09-11

    Recently, the configuration of the Tehran Research Reactor (TRR) thermal column has been modified and a proper thermal neutron beam for preclinical Boron Neutron Capture Therapy (BNCT) has been obtained. In this study, simulations and experimental measurements have been carried out to identify the BNCT beam parameters including the beam uniformity, the distribution of the thermal neutron dose, boron dose, gamma dose in a phantom and also the Therapeutic Gain (TG). To do this, the entire TRR structure including the reactor core, pool, the thermal column and beam tubes have been modeled using MCNPX Monte Carlo code. To measure in-phantom dose distribution a special head phantom has been constructed and foil activation techniques and TLD700 dosimeter have been used. The results show that there is enough uniformity in TRR thermal BNCT beam. TG parameter has the maximum value of 5.7 at the depth of 1 cm from the surface of the phantom, confirming that TRR thermal neutron beam has potential for being used in treatment of superficial brain tumors. For the purpose of a clinical trial, more modifications need to be done at the reactor, as, for example design, and construction of a treatment room at the beam exit which is our plan for future. To date, this beam is usable for biological studies and animal trials. There is a relatively good agreement between simulation and measurement especially within a diameter of 10 cm which is the dimension of usual BNCT beam ports. This relatively good agreement enables a more precise prediction of the irradiation conditions needed for future experiments.

  12. Upgrade of Beam Energy Measurement System at BEPC-II

    CERN Document Server

    Zhang, Jian-Yong; Mo, Xiao-Hu; Guo, Di-Zhou; Wang, Jian-Li; Liu, Bai-Qi; Achasov, M N; Krasnov, A A; Muchnoi, N Yu; Pyata, E E; Mamoshkina, E V; Harris, F A

    2015-01-01

    The beam energy measurement system is of great importance and profit for both BEPC-II accelerator and BES-III detector. The system is based on measuring the energies of Compton back-scattered photons. Many advanced techniques and precise instruments are employed to realize the highly accurate measurement of positron/electron beam energy. During five year's running period, in order to meet the requirement of data taking and improve the capacity of measurement itself, the upgradation of system is continued, which involve the component reformation of laser and optics subsystem, replacement of view-port of the laser to vacuum insertion subsystem, the purchase of electric cooling system for high purity germanium detector, and the improvement of data acquisition and processing subsystem. The upgrading of system guarantees the smooth and efficient measuring of beam energy at BEPC-II and accommodates the accurate offline energy values for further physics analysis at BES-III.

  13. Deflection estimation of a wind turbine blade using FBG sensors embedded in the blade bonding line

    Science.gov (United States)

    Kim, Sang-Woo; Kang, Woo-Ram; Jeong, Min-Soo; Lee, In; Kwon, Il-Bum

    2013-12-01

    Estimating the deflection of flexible composite wind turbine blades is very important to prevent the blades from hitting the tower. Several researchers have used fiber Bragg grating (FBG) sensors—a type of optical fiber sensor (OFS)—to monitor the structural behavior of the blades. They can be installed on the surface and/or embedded in the interior of composites. However, the typical installation positions of OFSs present several problems, including delamination of sensing probes and a higher risk of fiber breakage during installation. In this study, we proposed using the bonding line between the shear web and spar cap as a new installation position of embedded OFSs for estimating the deflection of the blades. Laboratory coupon tests were undertaken preliminarily to confirm the strain measuring capability of embedded FBG sensors in adhesive layers, and the obtained values were verified by comparison with results obtained by electrical strain gauges and finite element analysis. We performed static loading tests on a 100 kW composite wind turbine blade to evaluate its deflections using embedded FBG sensors positioned in the bonding line. The deflections were estimated by classical beam theory considering a rigid body rotation near the tip of the blade. The evaluated tip deflections closely matched those measured by a linear variable differential transformer. Therefore, we verified the capability of embedded FBG sensors for evaluating the deflections of wind turbine blades. In addition, we confirmed that the bonding line between the shear web and spar cap is a practical location to embed the FBG sensors.

  14. Effective shielding to measure beam current from an ion source

    Energy Technology Data Exchange (ETDEWEB)

    Bayle, H., E-mail: bayle@bergoz.com [Bergoz Instrumentation, Saint-Genis-Pouilly (France); Delferrière, O.; Gobin, R.; Harrault, F.; Marroncle, J.; Senée, F.; Simon, C.; Tuske, O. [CEA, Saclay (France)

    2014-02-15

    To avoid saturation, beam current transformers must be shielded from solenoid, quad, and RFQ high stray fields. Good understanding of field distribution, shielding materials, and techniques is required. Space availability imposes compact shields along the beam pipe. This paper describes compact effective concatenated magnetic shields for IFMIF-EVEDA LIPAc LEBT and MEBT and for FAIR Proton Linac injector. They protect the ACCT Current Transformers beyond 37 mT radial external fields. Measurements made at Saclay on the SILHI source are presented.

  15. Turbulence measurement with a two-beam nacelle lidar

    OpenAIRE

    Wagner, Rozenn; Sathe, Ameya; Mioullet, A.; Courtney, Michael

    2013-01-01

    The analysis of the turbulence intensity measurement is performed for a lidar measuring horizontally with two beams. First the turbulence intensity measured by such a system was evaluated theoretically. The Mann model of turbulence was used to evaluate the true value of the turbulence intensity of the wind speed and the main effects of the lidar measurement principles on turbulence intensity measurement were modeled:- A lidar senses the wind speed over the probe volume acting as a low pass-fi...

  16. Correction of beam-beam effects in luminosity measurement in the forward region at CLIC

    CERN Document Server

    Lukic, Strahinja

    2013-01-01

    Procedures for correcting the beam-beam effects in luminosity measurement at CLIC at 3 TeV CM energy are described and tested using Monte Carlo simulations: -> Correction of the angular counting loss due to the combined Beamstrahlung and initial-state radiation (ISR) effects, based on the reconstructed velocity of the collision frame of the Bhabha scattering. -> Deconvolution of the luminosity spectrum distortion due to the ISR emission. -> Correction of the counting bias due to the finite calorimeter energy resolution. All procedures were tested by simulation. Bhabha events were generated using BHLUMI, and used in Guinea-PIG to simulate the outgoing momenta of Bhabha particles in the bunch collisions at CLIC. Residual uncertainties after correction are listed in a table in the conclusions. The beam-beam related systematic counting uncertainty in the luminosity peak can be reduced to the order of permille.

  17. Correction of beam-beam effects in luminosity measurement in the forward region at CLIC

    CERN Document Server

    Lukic, Strahinja

    2013-01-01

    Procedures for correcting the beam-beam effects in luminosity measurement at CLIC at 3 TeV CM energy are described and tested using Monte Carlo simulations: - Correction of the angular counting loss due to the combined Beamstrahlung and initial-state radiation (ISR) effects, based on the reconstructed velocity of the collision frame of the Bhabha scattering. - Deconvolution of the luminosity spectrum distortion due to the ISR emission. - Correction of the counting bias due to the finite calorimeter energy resolution. All procedures were tested by simulation. Bhabha events were generated using BHLUMI, and used in Guinea-PIG to simulate the outgoing momenta of Bhabha particles in the bunch collisions at CLIC. Residual uncertainties after correction are listed in a table in the conclusions. The beam-beam related systematic counting uncertainty in the luminosity peak can be reduced to the order of permille.

  18. Deflection and Extraction of Pb Ions up to 33 TeV/c by a Bent Silicon Crystal

    Energy Technology Data Exchange (ETDEWEB)

    Arduini, G.; Biino, C.; Clement, M.; Cornelis, K.; Doble, N.; Elsener, K.; Ferioli, G.; Fidecaro, G.; Gatignon, L.; Grafstroem, P.; Gyr, M.; Herr, W.; Klem, J.; Mikkelsen, U.; Weisse, E. [SL Division, CERN, CH-1211 Geneva 23 (Switzerland); Mo/ller, S.P.; Uggerho/j, E. [ISA, Aarhus University (Denmark); Taratin, A. [JINR, Dubna (Russia); Freund, A. [ESRF, Grenoble (France); Keppler, P.; Major, J. [MPI fuer Metallforschung, Stuttgart (Germany)

    1997-11-01

    The first results from an experiment to deflect a beam of fully stripped, ultrarelativistic Pb{sup 82+} ions of 400 GeV/c per unit of charge, equivalent to 33 TeV/c , by means of a bent crystal are reported. Deflection efficiencies are as high as 14{percent}, in agreement with theoretical estimates. In a second experiment a bent crystal was used to extract 270 GeV/c -per-charge Pb{sup 82+} (22 TeV/c) ions from a coasting beam in the CERN-SPS, and a high extraction efficiency of up to 10{percent} was found. These represent the first measurements to demonstrate applications of bent crystals in high energy heavy ion beams. {copyright} {ital 1997} {ital The American Physical Society}

  19. Deflection and Extraction of Pb Ions up to 33 TeV/c by a Bent Silicon Crystal

    Science.gov (United States)

    Arduini, G.; Biino, C.; Clément, M.; Cornelis, K.; Doble, N.; Elsener, K.; Ferioli, G.; Fidecaro, G.; Gatignon, L.; Grafström, P.; Gyr, M.; Herr, W.; Klem, J.; Mikkelsen, U.; Weisse, E.; Møller, S. P.; Uggerhøj, E.; Taratin, A.; Freund, A.; Keppler, P.; Major, J.

    1997-11-01

    The first results from an experiment to deflect a beam of fully stripped, ultrarelativistic Pb82+ ions of 400 GeV/c per unit of charge, equivalent to 33 TeV/c, by means of a bent crystal are reported. Deflection efficiencies are as high as 14%, in agreement with theoretical estimates. In a second experiment a bent crystal was used to extract 270 GeV/c-per-charge Pb82+ \\(22 TeV/c\\) ions from a coasting beam in the CERN-SPS, and a high extraction efficiency of up to 10% was found. These represent the first measurements to demonstrate applications of bent crystals in high energy heavy ion beams.

  20. Deflection and extraction of Pb ions up to 33 TeV/c by a bent silicon crystal

    CERN Document Server

    Arduini, Gianluigi; Clément, M; Cornelis, Karel; Doble, Niels T; Elsener, K; Ferioli, G; Fidecaro, Giuseppe; Freund, A; Gatignon, L; Grafström, P; Gyr, Marcel; Herr, Werner; Keppler, P; Klem, J T; Major, J V; Mikkelsen, U; Møller, S P; Taratin, A M; Uggerhøj, Erik; Weisse, E

    1997-01-01

    The first results from an experiment to deflect a beam of fully stripped, ulta-relativistic Pb ions of 400 GeV/c per unit of charge, equivalent to 33 TeV/c, by means of a bent crystal are reported. Deflection efficiencies are as high as 14%, in agreement with theoretical predictions. In a second experiment a bent crsytal was used to extract 270 GeV/c per charge Pb82+ (22 TeV/c) ions from a coasting beam in the CERN-SPS, and a high extraction efficiency of up to 10% was found. These represent the first measurements to demonstrate applications of bent crystals in high energy heavy ion beams.

  1. ILC beam energy measurement by means of laser Compton backscattering

    Energy Technology Data Exchange (ETDEWEB)

    Muchnoi, N. [Budker Inst. for Nuclear Physics, Novosibirsk (Russian Federation); Schreiber, H.J.; Viti, M. [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany)

    2008-10-15

    A novel, non-invasive method of measuring the beam energy at the International Linear Collider is proposed. Laser light collides head-on with beam particles and either the energy of the Compton scattered electrons near the kinematic end-point is measured or the positions of the Compton backscattered {gamma}-rays, the edge electrons and the unscattered beam particles are recorded. A compact layout for the Compton spectrometer is suggested. It consists of a bending magnet and position sensitive detectors operating in a large radiation environment. Several options for high spatial resolution detectors are discussed. Simulation studies support the use of an infrared or green laser and quartz fiber detectors to monitor the backscattered photons and edge electrons. Employing a cavity monitor, the beam particle position downstream of the magnet can be recorded with submicrometer precision. Such a scheme provides a feasible and promising method to access the incident beam energy with precisions of 10{sup -4} or better on a bunch-to-bunch basis while the electron and positron beams are in collision. (orig.)

  2. Beam parametr measurements for the SLAC linear collider

    Energy Technology Data Exchange (ETDEWEB)

    Clendenin, J.E.; Blocker, C.; Breidenbach, M.

    1981-01-01

    A stable, closely-controlled, high-intensity, single-bunch beam will be required for the SLAC Linear Collider. The characteristics of short-pulse, low-intensity beams in the SLAC linac have been studied. A new, high-intensity thermionic gun, subharmonic buncher and S-band buncher/accelerator section were installed recently at SLAC. With these components, up to 10/sup 11/ electrons in a single S-band bunch are available for injection into the linac. the first 100-m accelerator sector has been modified to allow control of short-pulse beams by a model-driven computer program. Additional instrumentation, including a computerized energy analyzer and emittance monitor have been added at the end of the 100-m sector. The beam intensity, energy spectrum, emittance, charge distribution and the effect of wake fields in the first accelerator sector have been measured. The new source and beam control system are described and the most recent results of the beam parameter measurements are discussed.

  3. Experiments on Deflecting & Oscillating Waterjet

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    A new type jet,the oscillating & deflecting jet ,is put forward and its oscillating and deflecting characteristics are investigated.The nozzle of the self-oscillating & deflecting water jet consists of an upstream nozzle,a downstream nozzle,an oscillating chamber and two switches,It is experimentally shown that the deflective angle may reach 9.53 degeree,the generated pressure fluctuation is very regular and the jet can efficiently increase the ability for bradking and cutting by eliminating the water cushion effect associated with a continuous jet.

  4. Antiproton beam profile measurements using Gas Electron Multipliers

    CERN Document Server

    Pinto, Serge Duarte; Spanggaard, Jens; Tranquille, Gerard

    2011-01-01

    The new beam profile measurement for the Antiproton Decelerator (AD) at CERN is based on a single Gas Electron Multiplier (GEM) with a 2D readout structure. This detector is very light, ~0.4% X_0, as required by the low energy of the antiprotons, 5.3 MeV. This overcomes the problems previously encountered with multi-wire proportional chambers (MWPC) for the same purpose, where beam interactions with the detector severely affect the obtained profiles. A prototype was installed and successfully tested in late 2010, with another five detectors now installed in the ASACUSA and AEgIS beam lines. We will provide a detailed description of the detector and discuss the results obtained. The success of these detectors in the AD makes GEM-based detectors likely candidates for upgrade of the beam profile monitors in all experimental areas at CERN. The various types of MWPC currently in use are aging and becoming increasingly difficult to maintain.

  5. Measurement of stopping beam distributions in the PIBETA detector

    CERN Document Server

    Frlez, E; Li, W; Pocanic, D

    2006-01-01

    Precise calculation of the geometrical acceptance of a large solid angle detector with an integrated stopping target relies on precise knowledge of the beam geometry. We describe four alternative methods that we used to measure the beam stopping distributions in the PIBETA detector active target: (i) light response of segmented target elements to incident beam particles, (ii) back-tracking of charged particles from pi+ and mu+ decays using multi-wire proportional chambers, (iii) volume distribution of the Dalitz decay (pi0->gamma e+e-) event vertices, and (iv) the opening angle distribution of two pi0 photons originating from the beta decay of pi+ at rest. We demonstrate consistent results obtained by these four independent approaches and show how particular beam stopping distributions affect the detector's geometrical acceptance.

  6. Cherenkov Detector for Beam Quality Measurement

    CERN Document Server

    Orfanelli, Stella

    2015-01-01

    A new detector to measure the machine induced background at larger radiihas been developed and installed in the CMS experiment at LHC. Itconsists of 40 modules, each comprising a quartz bar read out by aphotomultiplier. Since Cerenkov radiation is emitted in a forward conearound the charged particle trajectory, these detectors can distinguishthe directions of the machine induced background.The back-end consists of a microTCA readout with excellent time resolution.The performance of the detector modules measured in several test-beamcampaigns will be reported. The installation in CMS will be described, andfirst results about operating the detector during data taking will begiven.

  7. Polystyrene calorimeter for electron beam dose measurements

    DEFF Research Database (Denmark)

    Miller, A.

    1995-01-01

    Calorimeters from polystrene have been constructed for dose measurement at 4-10 MeV electron accelerators. These calorimeters have been used successfully for a few years, and polystyrene calorimeters for use at energies down to 1 MeV and being tested. Advantage of polystyrene as the absorbing...

  8. Absolute beam emittance measurements at RHIC using ionization profile monitors

    Energy Technology Data Exchange (ETDEWEB)

    Minty, M. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Connolly, R [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Liu, C. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Summers, T. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Tepikian, S. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.

    2014-08-15

    In the past, comparisons between emittance measurements obtained using ionization profile monitors, Vernier scans (using as input the measured rates from the zero degree counters, or ZDCs), the polarimeters and the Schottky detectors evidenced significant variations of up to 100%. In this report we present studies of the RHIC ionization profile monitors (IPMs). After identifying and correcting for two systematic instrumental errors in the beam size measurements, we present experimental results showing that the remaining dominant error in beam emittance measurements at RHIC using the IPMs was imprecise knowledge of the local beta functions. After removal of the systematic errors and implementation of measured beta functions, precise emittance measurements result. Also, consistency between the emittances measured by the IPMs and those derived from the ZDCs was demonstrated.

  9. Nanosecond pulsed laser ablation of Ge investigated by employing photoacoustic deflection technique and SEM analysis

    Energy Technology Data Exchange (ETDEWEB)

    Yaseen, Nazish; Bashir, Shazia; Shabbir, Muhammad Kaif; Jalil, Sohail Abdul; Akram, Mahreen; Hayat, Asma; Mahmood, Khaliq; Haq, Faizan-ul; Ahmad, Riaz; Hussain, Tousif

    2016-06-01

    Nanosecond pulsed laser ablation phenomena of single crystal Ge (100) has been investigated by employing photoacoustic deflection as well as SEM analysis techniques. Nd: YAG laser (1064 nm, 10 ns, 1–10 Hz) at various laser fluences ranging from 0.2 to 11 J cm{sup −2} is employed as pump beam to ablate Ge targets. In order to evaluate in-situe ablation threshold fluence of Ge by photoacoustic deflection technique, Continuous Wave (CW) He–Ne laser (632 nm, power 10 mW) is employed as a probe beam. It travels parallel to the target surface at a distance of 3 mm and after passing through Ge plasma it causes deflection due to density gradient of acoustic waves. The deflected signal is detected by photodiode and is recorded by oscilloscope. The threshold fluence of Ge, the velocity of ablated species and the amplitude of the deflected signal are evaluated. The threshold fluence of Ge comes out to be 0.5 J cm{sup −2} and is comparable with the analytical value. In order to compare the estimated value of threshold with ex-situe measurements, the quantitative analysis of laser irradiated Ge is performed by using SEM analysis. For this purpose Ge is exposed to single and multiple shots of 5, 10, 50 and 100 at various laser fluences ranging from 0.2 to 11 J cm{sup −2}. The threshold fluence for single and multiple shots as well as incubation coefficients are evaluated. It is observed that the value of incubation co-efficient decreases with increasing number of pulses and is therefore responsible for lowering the threshold fluence of Ge. SEM analysis also reveals the growth of various features such as porous structures, non-uniform ripples and blisters on the laser irradiated Ge. It is observed that both the fluence as well as number of laser shots plays a significant role for the growth of these structures.

  10. Nanosecond pulsed laser ablation of Ge investigated by employing photoacoustic deflection technique and SEM analysis

    Science.gov (United States)

    Yaseen, Nazish; Bashir, Shazia; Shabbir, Muhammad Kaif; Jalil, Sohail Abdul; Akram, Mahreen; Hayat, Asma; Mahmood, Khaliq; Haq, Faizan-ul; Ahmad, Riaz; Hussain, Tousif

    2016-06-01

    Nanosecond pulsed laser ablation phenomena of single crystal Ge (100) has been investigated by employing photoacoustic deflection as well as SEM analysis techniques. Nd: YAG laser (1064 nm, 10 ns, 1-10 Hz) at various laser fluences ranging from 0.2 to 11 J cm-2 is employed as pump beam to ablate Ge targets. In order to evaluate in-situe ablation threshold fluence of Ge by photoacoustic deflection technique, Continuous Wave (CW) He-Ne laser (632 nm, power 10 mW) is employed as a probe beam. It travels parallel to the target surface at a distance of 3 mm and after passing through Ge plasma it causes deflection due to density gradient of acoustic waves. The deflected signal is detected by photodiode and is recorded by oscilloscope. The threshold fluence of Ge, the velocity of ablated species and the amplitude of the deflected signal are evaluated. The threshold fluence of Ge comes out to be 0.5 J cm-2 and is comparable with the analytical value. In order to compare the estimated value of threshold with ex-situe measurements, the quantitative analysis of laser irradiated Ge is performed by using SEM analysis. For this purpose Ge is exposed to single and multiple shots of 5, 10, 50 and 100 at various laser fluences ranging from 0.2 to 11 J cm-2. The threshold fluence for single and multiple shots as well as incubation coefficients are evaluated. It is observed that the value of incubation co-efficient decreases with increasing number of pulses and is therefore responsible for lowering the threshold fluence of Ge. SEM analysis also reveals the growth of various features such as porous structures, non-uniform ripples and blisters on the laser irradiated Ge. It is observed that both the fluence as well as number of laser shots plays a significant role for the growth of these structures.

  11. Measuring the phase of the scattering amplitude with vortex beams

    CERN Document Server

    Ivanov, I P

    2012-01-01

    We show that colliding vortex beams instead of (approximate) plane waves can lead to a direct measurement of how the overall phase of the scattering amplitude changes with the scattering angle. Since the overall phase is inaccessible in a plane wave collision, this measurement would be of great importance for a number of topics in hadronic physics, for example, for meson production in the resonance region and for the physics of nucleon resonances. Although the required parameters of the vortex beams have not yet been achieved experimentally, they deserves further dedicated experimental research due to the high expected physics pay-off.

  12. Performance of the beam phase measurement system for LEDA

    Science.gov (United States)

    Power, J. F.; Barr, D.; Gilpatrick, J. D.; Kasemir, K.; Shurter, R. B.; Stettler, M.

    2000-11-01

    The Low Energy Demonstration Accelerator (LEDA) facility diagnostics include beam phase measurements [1]. Beam signals at 350 MHz from capacitive probes are down-converted to 2 MHz for processing. The phase measurement process includes amplitude leveling, digital sampling of the I and Q vectors, DSP filtering and calibration, and serving of the data to the network. All hardware is fielded in the VXI format and controlled with a PC. Running under Windows NT, a LabVIEW® program controls the operation of the system and serves the data, via channel access, to the EPICS control system. The design and operational performance to date of the system is described.

  13. Three-dimensional measurement of a tightly focused laser beam

    Directory of Open Access Journals (Sweden)

    Xiangsheng Xie

    2013-02-01

    Full Text Available The spatial structure of a tightly focused light field is measured with a double knife-edge scanning method. The measurement method is based on the use of a high-quality double knife-edge fabricated from a right-angled silicon fragment mounted on a photodetector. The reconstruction of the three-dimensional structures of tightly focused spots is carried out with both uniform and partially obstructed linearly polarized incident light beams. The optical field distribution is found to deviate substantially from the input beam profile in the tightly focused region, which is in good agreement with the results of numerical simulations.

  14. Design of measurement equipment for high power laser beam shapes

    DEFF Research Database (Denmark)

    Hansen, K. S.; Olsen, F. O.; Kristiansen, Morten

    2013-01-01

    To analyse advanced high power beam patterns, a method, which is capable of analysing the intensity distribution in 3D is needed. Further a measuring of scattered light in the same system is preferred. This requires a high signal to noise ratio. Such a system can be realised by a CCD-chip impleme......To analyse advanced high power beam patterns, a method, which is capable of analysing the intensity distribution in 3D is needed. Further a measuring of scattered light in the same system is preferred. This requires a high signal to noise ratio. Such a system can be realised by a CCD...

  15. Calibration of Laser Beam Direction for Inner Diameter Measuring Device

    Directory of Open Access Journals (Sweden)

    Tongyu Yang

    2017-02-01

    Full Text Available The laser triangulation method is one of the most advanced methods for large inner diameter measurement. Our research group proposed a kind of inner diameter measuring device that is principally composed of three laser displacement sensors known to be fixed in the same plane measurement position. It is necessary to calibrate the direction of the laser beams that are emitted by laser displacement sensors because they do not meet the theoretical model accurately. For the purpose of calibrating the direction of laser beams, a calibration method and mathematical model were proposed. The inner diameter measuring device is equipped with the spindle of the machine tool. The laser beams rotate and translate in the plane and constitute the rotary rays which are driven to scan the inner surface of the ring gauge. The direction calibration of the laser beams can be completed by the sensors’ distance information and corresponding data processing method. The corresponding error sources are analyzed and the validity of the method is verified. After the calibration, the measurement error of the inner diameter measuring device reduced from ± 25 μ m to ± 15 μ m and the relative error was not more than 0.011%.

  16. Coupler induced monopole component and its minimization in deflecting cavities

    Directory of Open Access Journals (Sweden)

    P. K. Ambattu

    2013-06-01

    Full Text Available Deflecting cavities are used in particle accelerators for the manipulation of charged particles by deflecting or crabbing (rotating them. For short deflectors, the effect of the power coupler on the deflecting field can become significant. The particular power coupler type can introduce multipole rf field components and coupler-specific wakefields. Coupler types that would normally be considered like standard on-cell coupler, waveguide coupler, or mode-launcher coupler could have one or two rf feeds. The major advantage of a dual-feed coupler is the absence of monopole and quadrupole rf field components in the deflecting structure. However, a dual-feed coupler is mechanically more complex than a typical single-feed coupler and needs a splitter. For most applications, deflecting structures are placed in regions where there is small space hence reducing the size of the structure is very desirable. This paper investigates the multipole field components of the deflecting mode in single-feed couplers and ways to overcome the effect of the monopole component on the beam. Significant advances in performance have been demonstrated. Additionally, a novel coupler design is introduced which has no monopole field component to the deflecting mode and is more compact than the conventional dual-feed coupler.

  17. Electric Deflection of Rotating Molecules

    CERN Document Server

    Gershnabel, E

    2010-01-01

    We provide a theory of the deflection of polar and non-polar rotating molecules by inhomogeneous static electric field. Rainbow-like features in the angular distribution of the scattered molecules are analyzed in detail. Furthermore, we demonstrate that one may efficiently control the deflection process with the help of short and strong femtosecond laser pulses. In particular the deflection process may by turned-off by a proper excitation, and the angular dispersion of the deflected molecules can be substantially reduced. We study the problem both classically and quantum mechanically, taking into account the effects of strong deflecting field on the molecular rotations. In both treatments we arrive at the same conclusions. The suggested control scheme paves the way for many applications involving molecular focusing, guiding, and trapping by inhomogeneous fields.

  18. High-efficiency deflection of high energy protons due to channeling along the 〈110〉 axis of a bent silicon crystal

    Directory of Open Access Journals (Sweden)

    W. Scandale

    2016-09-01

    Full Text Available A deflection efficiency of about 61% was observed for 400 GeV/c protons due to channeling, most strongly along the 〈110〉 axis of a bent silicon crystal. It is comparable with the deflection efficiency in planar channeling and considerably larger than in the case of the 〈111〉 axis. The measured probability of inelastic nuclear interactions of protons in channeling along the 〈110〉 axis is only about 10% of its amorphous level whereas in channeling along the (110 planes it is about 25%. High efficiency deflection and small beam losses make this axial orientation of a silicon crystal a useful tool for the beam steering of high energy charged particles.

  19. Effect of beam quality on tilt measurement using cyclic interferometer

    Science.gov (United States)

    Pretheesh Kumar, V. C.; Ganesan, A. R.; Joenathan, C.; Somasundaram, U.

    2016-08-01

    Accurate measurement of angles is extremely important in various metrological applications. Interferometry has always been an excellent technique for accurate measurements. Several methods have been proposed for accurate tilt measurement using interferometric techniques. Almost all of them use the Michelson configuration which is extremely sensitive to environmental vibrations and turbulences. We know that a cyclic interferometer is extremely stable. Even though it is not sensitive to displacement changes, it is twice sensitive to tilt compared to that of a Michelson interferometer. We have enhanced the sensitivity to measure tilt using multiple reflections in a cyclic interferometer. Since the input beam is collimated, we have studied the effect of aberration of the input beam on the accuracy of tilt measurement. Experimental results on this study are presented in this paper.

  20. Random coincidences during in-beam PET measurements at microbunched therapeutic ion beams

    Science.gov (United States)

    Parodi, K.; Crespo, P.; Eickhoff, H.; Haberer, T.; Pawelke, J.; Schardt, D.; Enghardt, W.

    2005-06-01

    At the experimental carbon ion tumour therapy facility at GSI Darmstadt, in-beam positron emission tomography (PET) is used to monitor the dose delivery precision. A dual head positron camera has been assembled from commercial detector components in order to measure the β+-activity, induced by the irradiation, simultaneously to the dose application. Despite the positive clinical impact, the image quality is limited by the low counting statistics, orders of magnitude below that in standard PET applications to nuclear medicine. This paper investigates the origin for the noisy acquisition during particle extraction from the synchrotron of GSI. The results demonstrate the failure of standard random correction techniques due to a γ-ray background correlated in time with the carbon ion beam microstructure. This prevents the use of data acquired during beam extraction for imaging. The loss of counting statistics is expected to rise further at the future hospital-based facility at Heidelberg, due to a more efficient utilisation of the accelerator resulting in shorter beam pauses and a reduced treatment time. In this respect, this paper provides the basis for a new data acquisition concept tailored to the unconventional application of in-beam PET imaging to therapy monitoring at radiofrequency pulsed radiation sources.

  1. Emittance Measurements of Space Charge Dominated Electron Beam.

    Science.gov (United States)

    2014-09-26

    measurement 2,3 have been introduced in the past, especially in particle accelerator physics. In free space, the envelope of a non -neutral charged...density no and thickness 2d is located on the y-axis. Let us assume that the velocity space distribution is a Maxwellian with a temperature T and the beam

  2. Beam phase measurement in the AGOR-cyclotron

    NARCIS (Netherlands)

    Brandenburg, S; Roobol, LP; Schreuder, HW; de Vries, L; Laune, B; Baron, E.; Lieuvin, M.

    1999-01-01

    The AGOR cyclotron is equipped with thirteen phase probes for optimization of the isochronism The beam phase is measured at the 2(nd) harmonic of the RF frequency, in order to be able to suppress the large RF interference from the nearby resonators. At low RF frequencies a phase accuracy of 1 deg. i

  3. Beam asymmetry $\\Sigma$ measurements on the $\\pi^-$ photoproduction off neutrons

    CERN Document Server

    Mandaglio, G; Manganaro, M; Bellini, V; Bocquet, J P; Casano, L; D'Angelo, A; Di Salvo, R; Fantini, A; Franco, D; Gervino, G; Ghio, F; Giardina, G; Girolami, B; Giusa, A; Ignatov, A; Lapik, A; Sandri, P Levi; Lleres, A; Moricciani, D; Mushkarenkov, A N; Nedorezov, V; Randieri, C; Rebreyend, D; Rudnev, N V; Russo, G; Schaerf, C; Sperduto, M L; Sutera, M C; Turinge, A; Vegna, V; Briscoe, W J; Strakovsky, I I

    2010-01-01

    The $\\Sigma$ beam asymmetry in the photoproduction of negative pions from quasi-free neutrons in a deuterium target was measured at Graal in the energy interval 700 - 1500 MeV and a wide angular range, using polarized and tagged photons. The results are compared with recent partial wave analyses.

  4. Beam Current Measurement and Adjustment System on AMS

    Institute of Scientific and Technical Information of China (English)

    WUShao-yong; HEMING; SUSheng-yong; WANGZhen-jun; JIANGShan

    2003-01-01

    The beam current measurement and adjustment system of HI-13 tandem accelerator mass spectrometry detector system is consisted of the faraday cup, fluorescent target and a series of adjustable vertical slits(Fig. 1). The system's operation is very complicated and the transmission is low for the old system. A new system is instalated for improvement. We put the adjustable vertical slit, Faraday cup.

  5. Development of a photothermal double beam laser scanning system in biopharmaceutical applications

    Energy Technology Data Exchange (ETDEWEB)

    Faubel, W; Heissler, St; Schlegel, M [Institute of Functional Interfaces, Karlsruhe Institute of Technology, Herrmann- von-Helmholtz-Platz 1, D-76344 Eggenstein-Leopoldshafen (Germany); Gotter, B; Neubert, R H H, E-mail: werner.faubel@kit.ed [Institute of Pharmacy, Martin-Luther-University, Wolfgang-Langenbeck-Str. 4, D-06120 Halle/Saale (Germany)

    2010-03-01

    Photothermal beam deflection (PDS) has been applied to obtain information regarding the penetration of methylorange (MO) and ditranol (DI) into artificial membranes. The measurable depth range is 56 {mu}m. Photothermal beam deflection allows on the one hand depth resolved investigations by the use of a frequency modulation of the excitation beam to reach deeper regions even in opaque sample, and on the other hand lateral imaging. To explore the potential use of a novel photothermal double beam laser scanning system, measurements in drug delivery analysis have been used for depth profiling and imaging into an artificial membrane, which represents stratum corneum or bovine hoof, appropriately.

  6. A real-time, nonintrusive trace gas detector based on laser photothermal deflection

    Science.gov (United States)

    de Vries, H. S. M.; Dam, N.; van Lieshout, M. R.; Sikkens, C.; Harren, F. J. M.; Reuss, J.

    1995-09-01

    We present the layout and technical details of a trace gas monitor based on photothermal deflection. The operating principle of this instrument, i.e., the deflection of a (weak) probe laser beam by the thermal refractive index gradient induced by trace gas absorption of an intense pump laser beam, allows nonintrusive measurements with good space and time resolution. An intra-cavity CO2 laser is used as the pump beam and a red HeNe laser as the probe. The latter runs perpendicular to the pump beam to optimize spatial resolution. To increase sensitivity, the probe laser is incorporated in a multipass setup. The instrument is demonstrated by the localization of ethylene emission sites on a cherry tomato and by monitoring ammonia production due to nitrogen fixation by cyanobacteria. Both C2H4 and NH3 can be detected at the 1-3 ppb level, at a spatial resolution of 2 mm (along the pump laser)×0.6 mm (perpendicular to it), and a response time of 0.1 s (without background correction) or 15 s (including background correction). Sensitivity can be increased at the expense of spatial resolution, and vice versa. In principle, this instrument is applicable to all those gases possessing a characteristic (``fingerprint'') spectrum in the CO2 laser range. The great advantage of the photothermal deflection technique with respect to other trace gas detection schemes lies in the nonintrusive character of the measurements. There is no need to enclose the sample in a vessel or to suck large volumes of air into the detector; measurements can be performed in open air and in real time. This should prove especially useful where sticky (polar) gases, like H2O, NH3, CH3OH, etc., are to be detected quantitatively. Main applications include air quality monitoring, especially concerning dry deposition rate measurements using the eddy correlation technique, and the study of volatile metabolite emission of biological samples.

  7. Emittance Measurements For Future LHC Beams Using The PS Booster Measurement Line

    CERN Document Server

    Abelleira, Jose; Mikulec, Bettina; Di Giovanni, Gian Piero; CERN. Geneva. ATS Department

    2017-01-01

    The CERN PS Booster measurement line contains three pairs of SEM grids separated by drift space that measures the beam size in both planes. The combined analysis of these grids allows calculating a value for the transverse beam emittances. The precision of such a measurement depends on the ratio of RMS beam size and wire spacing. Within the LIU-PSB upgrade the extraction kinetic energy of the PSB will be increased from the current 1.4 GeV to 2.0 GeV. This will result in smaller transverse beam sizes for some of the future beams. The present layout of the transverse emittance measurement line is reviewed to verify if it will satisfy future requirements.

  8. Novel deflecting cavity design for eRHIC

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Q.; Belomestnykh, S.; Ben-Zvi, I.

    2011-07-25

    To prevent significant loss of the luminosity due to large crossing angle in the future ERL based Electron Ion Collider at BNL (eRHIC), there is a demand for crab cavities. In this article, we will present a novel design of the deflecting/crabbing 181 MHz superconducting RF cavity that will fulfil the requirements of eRHIC. The quarter-wave resonator structure of the new cavity possesses many advantages, such as compact size, high R{sub t}/Q, the absence of the same order mode and lower order mode, and easy higher order mode damping. We will present the properties and characteristics of the new cavity in detail. As the accelerator systems grow in complexity, developing compact and efficient deflecting cavities is of great interest. Such cavities will benefit situations where the beam line space is limited. The future linac-ring type electron-ion collider requires implementation of a crab-crossing scheme for both beams at the interaction region. The ion beam has a long bunches and high rigidity. Therefore, it requires a low frequency, large kicking angle deflector. The frequency of the deflecting mode for the current collider design is 181 MHz, and the deflecting angle is {approx}5 mrad for each beam. At such low frequency, the previous designs of the crab cavities will have very large dimensions, and also will be confronted by typical problems of damping the Lower Order Mode (LOM), the Same Order Mode (SOM), and as usual, the Higher Order Modes (HOM). In this paper we describe how one can use the concept of a quarter-wave (QW) resonator for a deflecting/crabbing cavity, and use its fundamental mode to deflect the beam. The simplicity of the cavity geometry and the large separation between its fundamental mode and the first HOM make it very attractive.

  9. Noninterceptive beam energy measurements in line D of the Los Alamos Meson Physics Facility

    Energy Technology Data Exchange (ETDEWEB)

    Gilpatrick, J.D.; Carter, H.; Plum, M.; Power, J.F.; Rose, C.R.; Shurter, R.B. [Los Alamos National Laboratory, M. S. H808, Los Alamos, New Mexico 87545 (United States)

    1995-05-05

    Several members of the Accelerator and Operations Technology (AOT) division beam-diagnostics team performed time-of-flight (TOF) beam-energy measurements in line D of the Los Alamos Meson Physics Facility (LAMPF) using developmental beam time. These measurements provided information for a final design of an on-line beam energy measurement. The following paper discusses these measurements and how they apply to the final beam energy measurement design. {copyright} {ital 1995} {ital American} {ital Institute} {ital of} {ital Physics}.

  10. Noninterceptive beam energy measurements in line D of the Los Alamos Meson Physics Facility

    Science.gov (United States)

    Gilpatrick, J. D.; Carter, H.; Plum, M.; Power, J. F.; Rose, C. R.; Shurter, R. B.

    1995-05-01

    Several members of the Accelerator and Operations Technology (AOT) division beam-diagnostics team performed time-of-flight (TOF) beam-energy measurements in line D of the Los Alamos Meson Physics Facility (LAMPF) using developmental beam time. These measurements provided information for a final design of an on-line beam energy measurement. The following paper discusses these measurements and how they apply to the final beam energy measurement design.

  11. Noninterceptive beam energy measurements in line D of the Los Alamos Meson Physics Facility

    Energy Technology Data Exchange (ETDEWEB)

    Gilpatrick, J.D.; Carter, H.; Plum, M.; Power, J.F.; Rose, C.R.; Shurter, R.B.

    1995-12-31

    Several members of the Accelerator and Operations Technology (AOT) division beam-diagnostics team performed time-of-flight (TOF) beam-energy measurements in line D of the Los Alamos Meson Physics Facility (LAMPF) using developmental beam time. These measurements provided information for a final design of an on-line beam energy measurement. The following paper discusses these measurements and how they apply to the final beam energy measurement design.

  12. Pulsed beams as field probes for precision measurement

    OpenAIRE

    Hudson, J. J.; Ashworth, H. T.; Kara, D. M.; Tarbutt, M. R.; Sauer, B.E.; Hinds, E. A.

    2007-01-01

    We describe a technique for mapping the spatial variation of static electric, static magnetic, and rf magnetic fields using a pulsed atomic or molecular beam. The method is demonstrated using a beam designed to measure the electric dipole moment of the electron. We present maps of the interaction region, showing sensitivity to (i) electric field variation of 1.5 V/cm at 3.3 kV/cm with a spatial resolution of 15 mm; (ii) magnetic field variation of 5 nT with 25 mm resolution; (iii) radio-frequ...

  13. Imaging and Measuring Electron Beam Dose Distributions Using Holographic Interferometry

    DEFF Research Database (Denmark)

    Miller, Arne; McLaughlin, W. L.

    1975-01-01

    Holographic interferometry was used to image and measure ionizing radiation depth-dose and isodose distributions in transparent liquids. Both broad and narrowly collimated electron beams from accelerators (2–10 MeV) provided short irradiation times of 30 ns to 0.6 s. Holographic images and measur......Holographic interferometry was used to image and measure ionizing radiation depth-dose and isodose distributions in transparent liquids. Both broad and narrowly collimated electron beams from accelerators (2–10 MeV) provided short irradiation times of 30 ns to 0.6 s. Holographic images...... and measurements of absorbed dose distributions were achieved in liquids of various densities and thermal properties and in water layers thinner than the electron range and with backings of materials of various densities and atomic numbers. The lowest detectable dose in some liquids was of the order of a few k...

  14. A Measure of Flow Vorticity with Helical Beams of Light

    CERN Document Server

    Rosales-Guzmán, Aniceto Belmonte Carmelo

    2015-01-01

    Vorticity describes the spinning motion of a fluid, i.e., the tendency to rotate, at every point in a flow. The interest in performing accurate and localized measurements of vorticity reflects the fact that many of the quantities that characterize the dynamics of fluids are intimately bound together in the vorticity field, being an efficient descriptor of the velocity statistics in many flow regimes. It describes the coherent structures and vortex interactions that are at the leading edge of laminar, transitional, and turbulent flows in nature. The measurement of vorticity is of paramount importance in many research fields as diverse as biology microfluidics, complex motions in the oceanic and atmospheric boundary layers, and wake turbulence on fluid aerodynamics. However, the precise measurement of flow vorticity is difficult. Here we put forward an optical sensing technique to obtain a direct measurement of vorticity in fluids using Laguerre-Gauss (LG) beams, optical beams which show an azimuthal phase vari...

  15. Research into the sampling methods of digital beam position measurement

    Institute of Scientific and Technical Information of China (English)

    邬维浩; 赵雷; 陈二雷; 刘树彬; 安琪

    2015-01-01

    A fully digital beam position monitoring system (DBPM) has been designed for SSRF (Shanghai Synchrotron Radiation Facility). As analog-to-digital converter (ADC) is a crucial part in the DBPM system, the sampling methods should be studied to achieve optimum performance. Different sampling modes were used and com-pared through tests. Long term variation among four sampling channels, which would introduce errors in beam position measurement, is investigated. An interleaved distribution scheme was designed to address this issue. To evaluate the sampling methods, in-beam tests were conducted in SSRF. Test results indicate that with proper sampling methods, a turn-by-turn (TBT) position resolution better than 1 µm is achieved, and the slow-acquisition (SA) position resolution is improved from 4.28 µm to 0.17 µm.

  16. Development of High Intensity Beam Emittance Measurement Unit

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    Three sets of High Intensity Beam Emittance Measurement Units (HIBEMUs) are being developed at Peking University. They are HIBEMU-2 (slit-wire type, one direction), HIBEMU-3 (Allison scanner type, one direction) and HIBEMU-4 (slit-wire type, two directions). For HIBEMU-2 and HIBEMU-3, more recent work has been done on software redesign in order to measure beam emittance and to draw phase diagram more efficiently and precisely. Software for control and data processing of them were developed in Labveiw environment, trying to improve calculation rationality and to offer user-friendly interface. Mechanical modification was also done for HIBEMU-3, mainly concentrating on the protection of Faraday cups from being overheated by the high intensity beam and also from interference of secondary electrons. This paper will also cover the mechanical structure as well as the software development of HIBEMU-4, which is a two-direction emittance scanner newly designed and manufactured for the high energy beam transport (HEBT) of Peking University Neutron Imaging FaciliTY (PKUNIFTY). At the end of this paper, comparison and analysis of the three HIBEMUs are given to draw forth better design of the future emittance measurement facility.

  17. Characterization of beam position monitors for measurement of second moment

    Energy Technology Data Exchange (ETDEWEB)

    Russell, S.J.; Gilpatrick, J.D.; Power, J.F.; Shurter, R.B.

    1995-05-01

    A dual-axis beam position monitor (BPM) consists of four electrodes placed at 90{degree} intervals around the probe aperture. The response signals of these lobes can be expressed as a sum of moments. The first order moment gives the centroid of the beam. The second order moment contains information about the rms size of the beam. It has been shown previously that the second order moment can be used to determine beam emittance. To make this measurement, the authors must characterize the BPM appropriately. The approach to this problem is to use a pulsed wire test fixture. By using the principle of superposition, they can build up a diffuse beam by taking the signals from different wire positions and summing them. This is done two ways: first by physically moving a wire about the aperture and building individual distributions, and, second, by taking a two dimensional grid of wire positions versus signal and using a computer to interpolate between the grid points to get arbitrary wire positions and, therefore, distributions. The authors present the current results of this effort.

  18. Simple red-beam attenuation meter for sea truth measurements

    Energy Technology Data Exchange (ETDEWEB)

    Haltrin, V.I.; Lee, M.E.; Martynov, O.V. [Naval Research Lab., Stennis Space Center, MS (United States)

    1996-11-01

    Red beam attenuation is useful in analyzing profiles of remotely sensed hydrooptical parameters and for accurate resolution of the vertical structure of chlorophyll and suspended particles. Hence, the development of a probing red beam attenuation meter has practical interest. Auto-collimating optical schematics with a cat`s eye have been used in the meter developed. The instrument is intended for application both as an independent device and as a module for oceanographic systems. High accuracy with minimal size and power consumption are realized by using electro-optical semiconductors. The dual beam principle of stabilization with negative optical feedback for the light emitting diode (LED) is applied. The exponential shape of LED modulated impulses causes the instrument output to be proportional to beam attenuation. By placing the optical attenuator into the reference beam one can compensate for pure water absorption and measure the volume scattering coefficient. The optical base of the cat`s eye can be varied from 50 cm on down. The device is not sensitive to ambient light. 12 refs., 2 figs., 1 tab.

  19. Measurement of microwave radiation from electron beam in the atmosphere

    Energy Technology Data Exchange (ETDEWEB)

    Ohta, I.S.; Akimune, H. [Faculty of Science and Engineering, Konan University, Kobe 658-8501 (Japan); Fukushima, M.; Ikeda, D. [Institute of Cosmic Ray Research, University of Tokyo, Kashiwa, Chiba 277-8582 (Japan); Inome, Y. [Faculty of Science and Engineering, Konan University, Kobe 658-8501 (Japan); Matthews, J.N. [University of Utah, Salt Lake City, UT 4112-0830 (United States); Ogio, S. [Graduate School of Science, Osaka City University, Osaka 558-8585 (Japan); Sagawa, H. [Institute of Cosmic Ray Research, University of Tokyo, Kashiwa, Chiba 277-8582 (Japan); Sako, T. [Solar-Terrestrial Environment Laboratory, Nagoya University, Nagoya 464-8601 (Japan); Shibata, T. [High Energy Accelerator Research Organization (KEK), Tsukuba 305-0801 (Japan); Yamamoto, T., E-mail: tokonatu@konan-u.ac.jp [Faculty of Science and Engineering, Konan University, Kobe 658-8501 (Japan)

    2016-02-21

    We report the use of an electron light source (ELS) located at the Telescope Array Observatory in Utah, USA, to measure the isotropic microwave radiation from air showers. To simulate extensive air showers, the ELS emits an electron beam into the atmosphere and a parabola antenna system for the satellite communication is used to measure the microwave radiation from the electron beam. Based on this measurement, an upper limit on the intensity of a 12.5 GHz microwave radiation at 0.5 m from a 10{sup 18} eV air shower was estimated to be 3.96×10{sup −16} W m{sup −2} Hz{sup −1} with a 95% confidence level.

  20. Beam Measurement Systems for the CERN Antiproton Decelerator (AD)

    CERN Document Server

    Angoletta, Maria Elena; Ludwig, M; Marqversen, O; Odier, P; Pedersen, F; Raich, U; Søby, L; Tranquille, G; Spickermann, T

    2001-01-01

    The new, low-energy antiproton physics facility at CERN has been successfully commissioned and has been delivering decelerated antiprotons at 100 MeV/c since July 2000. The AD consists of one ring where the 3.5 GeV/c antiprotons produced from a production target are injected, rf manipulated, stochastically cooled, decelerated (with further stages involving additional stochastic and electron cooling and rf manipulation) and extracted at 100 MeV/c. While proton test beams of sufficient intensity could be used for certain procedures in AD commissioning, this was not possible for setting-up and routine operation. Hence, special diagnostics systems had to be developed to obtain the beam and accelerator characteristics using the weak antiproton beams of a few 10E7 particles at all momenta from 3.5 GeV/c down to 100 MeV/c. These include systems for position measurement, intensity, beam size measurements using transverse aperture limiters and scintillators and Schottky-based tools. This paper gives an overall view of...

  1. Orthogonally interdigitated shielded serpentine travelling wave cathode ray tube deflection structure

    Science.gov (United States)

    Hagen, Edward C.; Hudson, Charles L.

    1995-01-01

    A new deflection structure (12) which deflects a beam of charged particles, uch as an electron beam (15), includes a serpentine set (20) for transmitting a deflection field, and a shielding frame (25) for housing the serpentine set (20). The serpentine set (20) includes a vertical serpentine deflection element (22) and a horizontal serpentine deflection element (24). These deflection elements (22, 24) are identical, and are interdigitatedly and orthogonally disposed relative to each other, for forming a central transmission passage (75), through which the electron beam (15) passes, and is deflected by the deflection field, so as to minimize drift space signal distortion. The shielding frame (25) includes a plurality of ground blocks (26, 28, 30, 32), and forms an internal serpentine trough (77) within these ground blocks, for housing the serpentine set (20). The deflection structure (12) further includes a plurality of feedthrough connectors (35, 37, 35I, 37I), which are inserted through the shielding frame (25), and which are electrically connected to the serpentine set (20).

  2. Turbulence measurement with a two-beam nacelle lidar

    DEFF Research Database (Denmark)

    Wagner, Rozenn; Sathe, Ameya; Mioullet, A.

    The analysis of the turbulence intensity measurement is performed for a lidar measuring horizontally with two beams. First the turbulence intensity measured by such a system was evaluated theoretically. The Mann model of turbulence was used to evaluate the true value of the turbulence intensity...... of the wind speed and the main effects of the lidar measurement principles on turbulence intensity measurement were modeled: - A lidar senses the wind speed over the probe volume acting as a low pass-filter and thus cannot resolve high frequency turbulence; - The horizontal wind speed is retrieved from...... the combination of the radial speeds measured along two line-of-sights with different orientations; this results in the contamination of the lidar turbulence intensity measurement from the transverse component of the wind field. Secondly, the theoretical results were compared to experimental measurements. A two...

  3. Deflection of Light by Gravity: A Physical Approach.

    Science.gov (United States)

    Diamond, Joshua B.

    1982-01-01

    Einstein's equivalence principle relates effects seen by an accelerating observer to those experienced by an observer in a gravitational field, providing an explanation of bending of a light beam by gravity. Because the calculations lead to results one-half the value found experimentally, obtaining the correct light deflection is discussed.…

  4. Beam splitting target reflector based compensation for angular drift of laser beam in laser autocollimation of measuring small angle deviations.

    Science.gov (United States)

    Zhu, Fan; Tan, Jiubin; Cui, Jiwen

    2013-06-01

    Beam splitting target reflector based compensation for the angular drift of laser beam in laser autocollimation is proposed in this article to improve the measurement accuracy and stability of small angle deviations. A beam splitting target reflector is used to replace the plane mirror in laser autocollimation to generate a reference beam when returning the measurement beam. The reference beam and measurement beam have the same angular drift, but have different sensitivities to the rotation angle of the reflector due to the unique characteristics of the reflector. Thus, the angular drift of laser beam in laser autocollimation can be compensated in real time by using the drift of reference beam. Experimental results indicate that an output stability of 0.085 arc sec in 2 h can be achieved after compensation. And a measurement accuracy of ±0.032 arc sec can be obtained over the range of ±1190 arc sec with an effective resolution of 0.006 arc sec. It is confirmed that the compensation method for the angular drift of laser beam is necessary for improving the measurement accuracy and stability in laser autocollimation.

  5. Beam splitting target reflector based compensation for angular drift of laser beam in laser autocollimation of measuring small angle deviations

    Energy Technology Data Exchange (ETDEWEB)

    Zhu Fan; Tan Jiubin; Cui Jiwen [Center of Ultra-precision Optoelectronic Instrument Engineering, Harbin Institute of Technology, Harbin 150080 (China)

    2013-06-15

    Beam splitting target reflector based compensation for the angular drift of laser beam in laser autocollimation is proposed in this article to improve the measurement accuracy and stability of small angle deviations. A beam splitting target reflector is used to replace the plane mirror in laser autocollimation to generate a reference beam when returning the measurement beam. The reference beam and measurement beam have the same angular drift, but have different sensitivities to the rotation angle of the reflector due to the unique characteristics of the reflector. Thus, the angular drift of laser beam in laser autocollimation can be compensated in real time by using the drift of reference beam. Experimental results indicate that an output stability of 0.085 arc sec in 2 h can be achieved after compensation. And a measurement accuracy of {+-}0.032 arc sec can be obtained over the range of {+-}1190 arc sec with an effective resolution of 0.006 arc sec. It is confirmed that the compensation method for the angular drift of laser beam is necessary for improving the measurement accuracy and stability in laser autocollimation.

  6. Measurement of neutron excitation functions using wide energy neutron beams

    Energy Technology Data Exchange (ETDEWEB)

    Loevestam, Goeran [EC-JRC-Institute for Reference Materials and Measurements (IRMM), Retieseweg 111, B-2440 Geel (Belgium)], E-mail: goeran.loevestam@ec.europa.eu; Hult, Mikael; Fessler, Andreas; Gamboni, Thierry; Gasparro, Joel; Geerts, Wouter; Jaime, Ricardo; Lindahl, Patric; Oberstedt, Stephan [EC-JRC-Institute for Reference Materials and Measurements (IRMM), Retieseweg 111, B-2440 Geel (Belgium); Tagziria, Hamid [EC-JRC-Institute for the Protection and the Security of the Citizen (IPSC), Via E. Fermi 1, I-21020 Ispra (Italy)

    2007-10-11

    A technique for measuring neutron excitation functions using wide energy neutron beams is explored. Samples are activated with a set of neutron fields, each covering a relatively wide energy interval and created using an ion accelerator and conventional nuclear reactions. Measured activities are determined using gamma-ray spectrometry and reduced to excitation curves using spectrum unfolding. The technique is demonstrated on the measurement of the excitation function curve up to 5.6 MeV for {sup 113}In(n,n'){sup 113}In{sup m} using the {sup 115}In(n,n'){sup 115}In{sup m} reaction as an internal standard.

  7. Beam Property Measurements on the KU-FEL Linac

    CERN Document Server

    Masuda, Kai; Kii, Toshiteru; Murakami, Shio; Ohgaki, Hideaki; Yamazaki, Tetsuo; Yoshikawa, Kiyoshi; Zen, Heishun

    2004-01-01

    An infrared FEL facility is under construction for advanced energy researches [1]. Electron beams of around 30 MeV have been obtained by an S-band 4.5-cell rf gun with a thermionic cathode, and a recently installed 3-m accelerating tube. A 180 degree arc consisting of three bending magnets have been also set up for bunch compression, and beam property measurements are under way. Transverse phase space distributions and resultant emittances have been obtained through the tomographic technique [2] by use of a quadrupole magnet, an alumina phosphor screen and a CCD camera. An OTR screen is being prepared for a higher spatial resolution as well as for longitudinal bunch shape measurements by use of a streak camera of 0.2 psec resolution. Comparison with the start-to-end simulation results [3] will be also presented.

  8. Galvanometer deflection: a precision high-speed system.

    Science.gov (United States)

    Jablonowski, D P; Raamot, J

    1976-06-01

    An X-Y galvanometer deflection system capable of high precision in a random access mode of operation is described. Beam positional information in digitized form is obtained by employing a Ronchi grating with a sophisticated optical detection scheme. This information is used in a control interface to locate the beam to the required precision. The system is characterized by high accuracy at maximum speed and is designed for operation in a variable environment, with particular attention placed on thermal insensitivity.

  9. Upgraded Fast Beam Conditions Monitor for CMS online luminosity measurement

    CERN Document Server

    Leonard, Jessica Lynn

    2014-01-01

    The CMS beam and radiation monitoring subsystem BCM1F during LHC Run I consisted of 8 individual diamond sensors situated around the beam pipe within the tracker detector volume, for the purpose of fast monitoring of beam background and collision products. Effort is ongoing to develop the use of BCM1F as an online bunch-by-bunch luminosity monitor. BCM1F will be running whenever there is beam in LHC, and its data acquisition is independent from the data acquisition of the CMS detector, hence it delivers luminosity even when CMS is not taking data. To prepare for the expected increase in the LHC luminosity and the change from 50 ns to 25 ns bunch separation, several changes to the system are required, including a higher number of sensors and upgraded electronics. In particular, a new real-time digitizer with large memory was developed and is being integrated into a multi-subsystem framework for luminosity measurement. Current results from Run II preparation will be shown, including results from the January 201...

  10. Upgraded Fast Beam Conditions Monitor for CMS online luminosity measurement

    CERN Document Server

    Leonard, Jessica Lynn; Hempel, Maria; Henschel, Hans; Karacheban, Olena; Lange, Wolfgang; Lohmann, Wolfgang; Novgorodova, Olga; Penno, Marek; Walsh, Roberval; Dabrowski, Anne; Guthoff, Moritz; Loos, R; Ryjov, Vladimir; Burtowy, Piotr; Lokhovitskiy, Arkady; Odell, Nathaniel; Przyborowski, Dominik; Stickland, David P; Zagozdzinska, Agnieszka

    2014-01-01

    The CMS beam condition monitoring subsystem BCM1F during LHC Run I consisted of 8 individual diamond sensors situated around the beam pipe within the tracker detector volume, for the purpose of fast monitoring of beam background and collision products. Effort is ongoing to develop the use of BCM1F as an online bunch-by-bunch luminosity monitor. BCM1F will be running whenever there is beam in LHC, and its data acquisition is independent from the data acquisition of the CMS detector, hence it delivers luminosity even when CMS is not taking data. To prepare for the expected increase in the LHC luminosity and the change from 50 ns to 25 ns bunch separation, several changes to the system are required, including a higher number of sensors and upgraded electronics. In particular, a new real-time digitizer with large memory was developed and is being integrated into a multi-subsystem framework for luminosity measurement. Current results from Run II preparation will be discussed, including results from the January 201...

  11. Measurements of the $^{12}$C Ion Beam Microdosimetric Characteristics

    CERN Document Server

    Molokanov, A G

    2005-01-01

    The results of experimental studies of the $^{12}$C ion beam with the primary energy of 500 MeV/amu from the JINR Nuclotron are presented. Depth-dose distributions have been measured by means of a diamond detector. The spectra of the linear energy transfer (LET) were studied at various beam penetration depths at several points from the beam entrance up to the region behind the Bragg peak by means of chemically etched track detectors. The track parameters were measured by means of an automatic optical image analyzer LUCIA-G based on a Leitz microscope. The value of the relative biological weighted effectiveness (RBWE), characterizing the value of the RBE during tumours radiotherapy, was calculated from the measured LET spectra on the basis of a biological weighting function. RBWE increases with the depth in the phantom, reaching the maximum value of about 3 just before the Bragg peak. Afterwards it decreases rather rapidly, which is to be considered when extended tumours are to be treated.

  12. Biomechanics of hair cell kinocilia: experimental measurement of kinocilium shaft stiffness and base rotational stiffness with Euler-Bernoulli and Timoshenko beam analysis.

    Science.gov (United States)

    Spoon, Corrie; Grant, Wally

    2011-03-01

    Vestibular hair cell bundles in the inner ear contain a single kinocilium composed of a 9+2 microtubule structure. Kinocilia play a crucial role in transmitting movement of the overlying mass, otoconial membrane or cupula to the mechanotransducing portion of the hair cell bundle. Little is known regarding the mechanical deformation properties of the kinocilium. Using a force-deflection technique, we measured two important mechanical properties of kinocilia in the utricle of a turtle, Trachemys (Pseudemys) scripta elegans. First, we measured the stiffness of kinocilia with different heights. These kinocilia were assumed to be homogenous cylindrical rods and were modeled as both isotropic Euler-Bernoulli beams and transversely isotropic Timoshenko beams. Two mechanical properties of the kinocilia were derived from the beam analysis: flexural rigidity (EI) and shear rigidity (kGA). The Timoshenko model produced a better fit to the experimental data, predicting EI=10,400 pN μm(2) and kGA=247 pN. Assuming a homogenous rod, the shear modulus (G=1.9 kPa) was four orders of magnitude less than Young's modulus (E=14.1 MPa), indicating that significant shear deformation occurs within deflected kinocilia. When analyzed as an Euler-Bernoulli beam, which neglects translational shear, EI increased linearly with kinocilium height, giving underestimates of EI for shorter kinocilia. Second, we measured the rotational stiffness of the kinocilium insertion (κ) into the hair cell's apical surface. Following BAPTA treatment to break the kinocilial links, the kinocilia remained upright, and κ was measured as 177±47 pN μm rad(-1). The mechanical parameters we quantified are important for understanding how forces arising from head movement are transduced and encoded by hair cells.

  13. Current Measurements of Low-Intensity Beams at CRYRING

    CERN Document Server

    Paál, A; Källberg, A

    2003-01-01

    The demand for new ion species leads to an increasing number of cases in which the ions can only be produced in small quantities. Thus, weak ion currents quite often have to be handled in low energy ion storage ring, like CRYRING. Various detector systems have been developed to measure such low intensity coasting and bunched beams by using the overlapping ranges of those systems. We have extended the RMS resolution to 1 nA of the Bergoz Beam Charge Monitor (BCM) by using a low noise 60 dB preamplifier for the Integrating Current Transformer. The sum signal of a capacitive pick-up is integrated by a second gated integrator and the BCM output signal is used for calibration. The RMS resolution is about 100 pA.. To measure the coasting beam intensity, neutral particle detectors have been built. The fast Microchannel plate detector can handle 1 Mc/s, and a 50 Mc/s Secondary Electron Multiplier based detector is under construction. On the magnetic flat top, a time of 100 ms is available to calibrate the count r...

  14. Flow sensing by buckling monitoring of electrothermally actuated double-clamped micro beams

    CERN Document Server

    Kessler, Yoav; Liberzon, Alex

    2016-01-01

    We report on a flow sensing approach based on deflection monitoring of micro beams buckled by the compressive thermal stress due to electrothermal Joules heating. The air stream convectively cooling the device affects both the critical buckling values of the electric current and the postbuckling deflections of the structure. After calibration, the flow velocity was obtained from the deflections measurements. The quasi-static responses of 2000 microns long, 10 microns wide and 30 microns high single crystal silicon beam transduced using image processing were consistent with the prediction of the reduced order model, which couples thermoelectric, thermofluidic and structural domains. The deflection sensitivity of 1.5 microns/(m/s) and the critical current sensitivity of 0.4 mA/(m/s) were registered in the experiments. Our model and experimental results collectively demonstrate feasibility of the sensing approach and further suggest that simple, robust and potentially downscalable beam-type devices may have use ...

  15. Online measurement of fluence and position for protontherapy beams

    Science.gov (United States)

    Benati, C.; Boriano, A.; Bourhaleb, F.; Cirio, R.; Cirrone, G. A. P.; Cornelius, I.; Cuttone, G.; Donetti, M.; Garelli, E.; Giordanengo, S.; Guérin, L.; La Rosa, A.; Luparia, A.; Marchetto, F.; Martin, F.; Meyroneinc, S.; Peroni, C.; Pittà, G.; Raffaele, L.; Sabini, M. G.; Valastro, L.

    2004-09-01

    Tumour therapy with proton beams has been used for several decades in many centres with very good results in terms of local control and overall survival. Typical pathologies treated with this technique are located in head and neck, eye, prostate and in general at big depths or close to critical organs. The Experimental Physics Department of the University of Turin and the local Section of INFN, in collaboration with INFN Laboratori Nazionali del Sud Catania and Centre de Protontherapie de Orsay Paris, have developed detector systems that allow the measurement of beam position and fluence, obtained in real time during beam delivery. The centre in Catania (CATANA: Centro di AdroTerapia ed Applicazioni Nucleari Avanzate) has been treating patients with eye pathologies since spring 2002 using a superconducting cyclotron accelerating protons up to 62 MeV.This kind of treatments need high-resolution monitor systems and for this reason we have developed a 256-strip segmented ionisation chamber, each strip being 400 μm wide, with a total sensitive area 13×13 cm2. The Centre de Protontherapie de Orsay (CPO) has been operational since 1991 and features a synchrocyclotron used for eye and head and neck tumours with proton beams up to 200 MeV. The monitor system has to work on a large surface and for this purpose we have designed a pixel-segmented ionisation chamber, each pixel being 5×5 mm2, for a total active area of 16×16 cm2. The results obtained with two prototypes of the pixel and strip chambers demonstrate that the detectors allow the measurement of fluence and centre of gravity as requested by clinical specifications.

  16. Dynamic steering beams for efficient force measurement in optical manipulation

    Institute of Scientific and Technical Information of China (English)

    Xiaocong Yuan; Yuquan Zhang; Rui Cao; Xing Zhao; Jing Bu; Siwei Zhu

    2011-01-01

    @@ An efficient and inexpensive method that uses a glass plate mounted onto a motorized rotating stage as a beam-steering device for the generation of dynamic optical traps is reported.Force analysis reveals that there are drag and trapping forces imposed on the bead in the opposite directions, respectively, in a viscous medium.The trapped bead will be rotated following the beam's motion before it reaches the critical escape velocity when the drag force is equal to the optical trapping force.The equilibrium condition facilitates the experimental measurement of the drag force with potential extensions to the determination of the viscosity of the medium or the refractive index of the bead.The proposed technique can easily be integrated into conventional optical microscopic systems with minimum modifications.%An efficient and inexpensive method that uses a glass plate mounted onto a motorized rotating stage as a beam-steering device for the generation of dynamic optical traps is reported. Force analysis reveals that there are drag and trapping forces imposed on the bead in the opposite directions, respectively, in a viscous medium. The trapped bead will be rotated following the beam's motion before it reaches the critical escape velocity when the drag force is equal to the optical trapping force. The equilibrium condition facilitates the experimental measurement of the drag force with potential extensions to the determination of the viscosity of the medium or the refractive index of the bead. The proposed technique can easily be integrated into conventional optical microscopic systems with minimum modifications.

  17. DC proton beam measurements in a single-solenoid low-energy beam transport system

    Energy Technology Data Exchange (ETDEWEB)

    Stevens, R.R. Jr.; Schafstall, P.; Schneider, J.D.; Sherman, J.; Zaugg, T. [Los Alamos National Lab., NM (United States); Taylor, T. [AECL Research, Chalk River, Ontario (Canada). Chalk River Labs.

    1994-09-01

    High current, CW proton accelerators are being considered for a number of applications including disposition of nuclear wastes, reduction of fissionable nuclear material inventories, safe production of critical nuclear materials, and energy production. All these applications require the development of high current, reliable, hydrogen ion injectors. In 1986, a program using CW RFQ technology was undertaken at CRL in collaboration with LANL and was continued there until 1993. During this time, an accelerator was built which produced 600 keV, 75 mA and 1,250 keV, 55 mA CW proton beams. The present program at Los Alamos using this accelerator is aimed at continuing the CRL work to demonstrate long-term reliability. In the present work, the authors are seeking to determine the optimal match to and the current limit of the 1,250-keV RFQ. This paper discusses the characterization of the 50 keV beams at the exit of the single-solenoid LEBT and presents both the experimental measurements and the beam simulations done to model this system.

  18. Beam lifetime measurement and analysis in Indus-2 electron storage ring

    Indian Academy of Sciences (India)

    Pradeep Kumar; A D Ghodke; Gurnam Singh

    2013-05-01

    In this paper, the beam lifetime measurement and its theoretical analysis are presented using measured vacuum pressure and applied radio frequency (RF) cavity voltage in Indus-2 electron storage ring at 2 GeV beam energy. Experimental studies of the effect of RF cavity voltage and bunched beam filling pattern on beam lifetime are also presented. An equation of stable beam current decay is evolved and this equation closely follows the observed beam current decay pattern. It shows that the beam is stable and the beam current decay is due to the beam–residual gas interaction (vacuum lifetime) and electron–electron interaction within a bunch (Touschek lifetime). The estimated vacuum, Touschek and total beam lifetimes from analytical formulations are also compared with the measured beam lifetime.

  19. Measuring g with a beam of antihydrogen (AEgIS)

    CERN Document Server

    Canali, C

    2011-01-01

    The gravitational interaction between matter and antimatter has never been tested experimentally. According to some attempts to unify gravity with the other forces, the possibility that $g(p) 6= g\\bar{(p)}$ cannot be excluded 1 . The AEGIS experiment 2 intends to measure for the first time the gravitational acceleration of antimatter using cold antihydrogen atoms. Antihydrogen atoms will be obtained trough a charge exchange process between Rydberg positronium atoms and antiprotons. Once $\\bar{H}$ are accelerated to form a horizontal beam, they travel through a Moire deflectometer, able to measure the vertical displacement of atoms due to gravity. Knowing the velocity of the antiatoms from the time of flight measurement and the length of the flight path allows to estimate the gravity acceleration g for antihydrogen. With this setup an initial precision on the measure of g of 1% is expected.

  20. Performance measurement of broadband, wide-angle polarizing beam splitter

    Institute of Scientific and Technical Information of China (English)

    CHEN Wei-bin; ZHENG Zhen-rong; GU Pei-fu; ZHANG Yue-guang

    2007-01-01

    Polarizing beam splitter (PBS) is a critical optical component in projection display system because PBS performance greatly influences the contrast and brightness of the system. PBS performance is usually measured by spectrophotometer after coating and cementing, but the measured result cannot represent the actual performance in practice because people usually change the incident angle in one plane (horizontal plane) and do not consider the other plane (vertical plane). Geometrical polarization rotation occurring at reduced F-number influences the measuring precision of s-polarization transmittance (Ts) and p-polarization reflectance (Rp). A more accurate and practical way to measure the performance of broadband, wide-angle PBS is presented in this paper.

  1. Nondestructive Measurement of Orbital Angular Momentum for an Electron Beam

    Science.gov (United States)

    Larocque, Hugo; Bouchard, Frédéric; Grillo, Vincenzo; Sit, Alicia; Frabboni, Stefano; Dunin-Borkowski, Rafal E.; Padgett, Miles J.; Boyd, Robert W.; Karimi, Ebrahim

    2016-10-01

    Free electrons with a helical phase front, referred to as "twisted" electrons, possess an orbital angular momentum (OAM) and, hence, a quantized magnetic dipole moment along their propagation direction. This intrinsic magnetic moment can be used to probe material properties. Twisted electrons thus have numerous potential applications in materials science. Measuring this quantity often relies on a series of projective measurements that subsequently change the OAM carried by the electrons. In this Letter, we propose a nondestructive way of measuring an electron beam's OAM through the interaction of this associated magnetic dipole with a conductive loop. Such an interaction results in the generation of induced currents within the loop, which are found to be directly proportional to the electron's OAM value. Moreover, the electron experiences no OAM variations and only minimal energy losses upon the measurement, and, hence, the nondestructive nature of the proposed technique.

  2. Substrate heating measurements in pulsed ion beam film deposition

    Energy Technology Data Exchange (ETDEWEB)

    Olson, J.C.; Davis, H.A.; Rej, D.J.; Waganaar, W.J. [Los Alamos National Lab., NM (United States); Tallant, D.R. [Cornell Univ., Ithaca, NY (United States). Materials Science and Engineering Dept.; Thompson, M.O. [Sandia National Labs., Albuquerque, NM (United States)

    1995-05-01

    Diamond-like Carbon (DLC) films have been deposited at Los Alamos National Laboratory by pulsed ion beam ablation of graphite targets. The targets were illuminated by an intense beam of hydrogen, carbon, and oxygen ions at a fluence of 15-45 J/cm{sup 2}. Ion energies were on the order of 350 keV, with beam current rising to 35 kA over a 400 ns ion current pulse. Raman spectra of the deposited films indicate an increasing ratio of sp{sup 3} to sp{sup 2} bonding as the substrate is moved further away from the target and further off the target normal. Using a thin film platinum resistor at varying positions, we have measured the heating of the substrate surface due to the kinetic energy and heat of condensation of the ablated material. This information is used to determine if substrate heating is responsible for the lack of DLC in positions close to the target and near the target normal. Latest data and analysis will be presented.

  3. In vacuum diamond sensor scanner for beam halo measurements in the beam line at the KEK Accelerator Test Facility

    Science.gov (United States)

    Liu, S.; Bogard, F.; Cornebise, P.; Faus-Golfe, A.; Fuster-Martínez, N.; Griesmayer, E.; Guler, H.; Kubytskyi, V.; Sylvia, C.; Tauchi, T.; Terunuma, N.; Bambade, P.

    2016-10-01

    The investigation of beam halo transverse distributions is important for the understanding of beam losses and the control of backgrounds in Future Linear Colliders (FLC). A novel in vacuum diamond sensor (DSv) scanner with four strips has been designed and developed for the investigation of the beam halo transverse distributions and also for the diagnostics of Compton recoil electrons after the interaction point (IP) of ATF2, a low energy (1.3 GeV) prototype of the final focus system for the ILC and CLIC linear collider projects. Using the DSv, a dynamic range of ∼106 has been successfully demonstrated and confirmed for the first time in simultaneous beam core (∼109 electrons) and beam halo (∼103 electrons) measurements at ATF2. This report presents the characterization, performance studies and tests of diamond sensors using an α source, as well as using the electron beams at PHIL, a low energy < 5 MeV photo-injector at LAL, and at ATF2. First beam halo measurement results using the DSv at ATF2 with different beam intensities and vacuum levels are also presented. Such measurements not only allow one to evaluate the different sources of beam halo generation but also to define the requirements for a suitable collimation system to be installed at ATF2, as well as to optimize its performance during future operation.

  4. Measurement of the Vector and Tensor Polarisation of Proton and Deuteron Beams

    CERN Document Server

    Lesiak, M; Budzanowski, A; Chatterjee, A; Ernst, J; Gebel, R; Hawranek, P; Jahn, R; Jha, V; Kilian, K; Kliczewski, S; Kirillov, Da; Kirillov, Di; Kolev, D; Kravcikova, M; Kutsarova, T; Lieb, J; Machner, H; Magiera, A; Maier, R; Martinská, G; Nedev, S; Piskunov, N; Prasuhn, D; Protic, D; Rossen, P; Roy, B J; Sitnik, I; Siudak, R; Tsenov, R V; Ulicny, M; Urbán, J; Vankova, G; Wilkin, C

    2005-01-01

    Measurement of the d + d -> 4He + eta reaction using vector and tensor polarised beam has been performed at COSY using Big Karl magnetic spectrograph. The beam polarisation necessary for obtaining the vector and tensor analysing power for this reaction was measured. The method and the results of the tensor polarisation measurement of the deuteron beam are presented.

  5. Benchmarking Asteroid-Deflection Experiment

    Science.gov (United States)

    Remington, Tane; Bruck Syal, Megan; Owen, John Michael; Miller, Paul L.

    2016-10-01

    An asteroid impacting Earth could have devastating consequences. In preparation to deflect or disrupt one before it reaches Earth, it is imperative to have modeling capabilities that adequately simulate the deflection actions. Code validation is key to ensuring full confidence in simulation results used in an asteroid-mitigation plan. We are benchmarking well-known impact experiments using Spheral, an adaptive smoothed-particle hydrodynamics code, to validate our modeling of asteroid deflection. We describe our simulation results, compare them with experimental data, and discuss what we have learned from our work. This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344. LLNL-ABS-695540

  6. Process nano scale mechanical properties measurement of thin metal films using a novel paddle cantilever test structure

    CERN Document Server

    Tong, Chi-Jia

    2008-01-01

    A new technique was developed for studying the mechanical behavior of nano-scale thin metal films on substrate is presented. The test structure was designed on a novel "paddle" cantilever beam specimens with dimensions as few hundred nanometers to less than 10 nanometers. This beam is in triangle shape in order to provide uniform plane strain distribution. Standard clean room processing was used to prepare the paddle sample. The experiment can be operated by using the electrostatic deflection on the paddle uniform distributed stress cantilever beam and then measure the deposited thin metal film materials on top of it. A capacitance technique was used to measurement on the other side of the deflected plate to measure its deflection with respect to the force. The measured strain was converted through the capacitance measurement for the deflection of the cantilever. System performance on the residual stress measurement of thin films are calculated with three different forces on the "paddle" cantilever beam, incl...

  7. Measuring Atomic and Molecular Species in the Upper Atmosphere up to 1000 km with the Free-Fall Mass Spectrometer and the Small Deflection Energy Analyzer

    Science.gov (United States)

    Herrero, F.; Nicholas, A.

    2007-05-01

    Atomic oxygen (O), the major constituent of the Earth's thermosphere above 200 km altitude is both a driver and a tracer of atmospheric motions in the thermosphere and plays a pivotal role in interactions with the ionosphere through ion-drag and chemical reactions. At altitudes above 400 to 500 km, the energies and composition may reveal interactions with the magnetosphere. In addition, satellites in low-Earth orbit require knowledge of O densities to address engineering issues in low-Earth-orbit missions. The major difficulties in O measurements involve ambiguities due to the recombination of O in the sensor surfaces to yield O2 which is then measured with a mass spectrometer; similar difficulties exist for atomic hydrogen H and nitrogen N. In this paper we describe the use of our new charged particle spectrometers to measure relative densities and energies of the neutral and ion constituents in the upper atmosphere and into the exosphere to about 1000 km altitude. Neutral atoms are ionized before striking internal surfaces and surface-accommodated atoms and molecules are discriminated from incident ones according to their energies. Our ion source sensitivity is about 1.3x10-4/s per microAmp electron beam current for a number density of 1/cm3. Thus, operating with 1 mA emission (about 0.2W cathode power), signals of 100/s with integration period of 1 second correspond to a neutral atom density of about 103/cm3 with 10% variance. At very high altitudes, the lowest densities occur with the coldest thermopause - a 750K thermopause having an O density of about 150/cm3 at 1000 km, much higher densities for H and He, and much lower for O2 and N2. Total power for the spectrometer suite is less than 0.5 W with a mass of about 0.5 kg, based on our current versions. We plan to propose development of the sensor suite for two missions; one at 400 km and one at 830 km.

  8. Beam Spin Asymmetry Measurements for Two Pion Photoproduction at CLAS

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, Mark D. [Univ. of Glasgow, Scotland (United Kingdom)

    2015-09-01

    The overarching goal of this analysis, and many like it, is to develop our understanding of the strong force interactions within the nucleon by examining the nature of their excitation spectra. As the resonances of these spectra have very short lifetimes (tau = 1x10-23 s) and often have very similar masses, it is often impossible to directly observe resonances in the excitation spectra of nucleons. Polarization observables allow us to study the resonances by looking at how they affect the spin state of final state particles. The beam asymmetry is a polarization observable that allows us to detect the sensitivity of these resonances, and other transition mechanisms, to the electric vector orientation of incident photons. Presented in this thesis are first measurements of the beam asymmetries in the resonant region for the reaction channel pgamma p --> p π+ π-focusing on the intermediate mesonic states rho^0 and f^0, and the final state pions. The analysis used data from the g8b experiment undertaken at the Thomas Jefferson National Accelerator Facility (JLab), the first experiment at JLab to use a linearly polarized photon beam. Using the coherent Bremsstrahlung facility and the CLAS detector of Hall B at JLab allowed for many multi-channel reactions to be detected and the first measurements of many polarization observables including those presented here. A brief overview of the theoretical framework used to undertake this analysis is given, followed by a description of the experimental details of the facilities used, then a description of the calibration of the Bremsstrahlung tagging facility which the author undertook, and finally the analysis is presented and the resulting measurements.

  9. Measurement and Simulation of Beam Centering on CYCIAE-10

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    The beam centering is very important for the compact cyclotron, especially for the cyclotrons with the axial injection. It is critical that the cyclotron has a good beam centering to increase the beam current and reduce the beam loss. In the accelerating process,

  10. LIF Diagnostic for Measuring Beam-Transport Magnetic Fields

    Science.gov (United States)

    Jones, T. G.; Hinshelwood, D. D.; Neri, J. M.; Ottinger, P. F.; Noonan, W. A.

    1997-11-01

    A novel, spatially-resolved diagnostic is being developed to measure magnetic fields associated with intense ion beam propagation through a low-pressure gas, as is envisioned for light ion-driven ICF. The diagnostic technique uses laser-induced fluorescence (LIF) spectroscopy, and can be varied to measure either small or large fields. Small fields, as expected in ballistic transport with solenoidal lens focusing using ~ 1 Torr gas, produce Zeeman shifts, Δ λ_Z, smaller than the transition linewidth, Δ λ. High sensitivity to measure these shifts is achieved by a variation on the Babcock technique.^1 Large fields, as expected in self-pinched transport using 1--100 mTorr gas, produce Δ λZ larger than Δ λ. These Δ λZ will be resolved using an etalon as a narrowband, high-throughput optical filter. Available results from benchtop experiments using calibrated B-fields for both the small- and large-field techniques, and progress in fielding this diagnostic on the Gamble-II accelerator for beam-transport studies will be presented. Work supported by DOE through Sandia National Laboratories. ^ National Research Council Research Associate. ^ Present address University of Maryland, College Park, MD. ^1 W.A. Noonan, et al., Rev. Sci. Instrum. 68, 1032 (1997).

  11. Scintillation screen materials for beam profile measurements of high energy ion beams

    Energy Technology Data Exchange (ETDEWEB)

    Krishnakumar, Renuka

    2016-06-22

    For the application as a transverse ion beam diagnostics device, various scintillation screen materials were analysed. The properties of the materials such as light output, image reproduction and radiation stability were investigated with the ion beams extracted from heavy ion synchrotron SIS-18. The ion species (C, Ne, Ar, Ta and U) were chosen to cover the large range of elements in the periodic table. The ions were accelerated to the kinetic energies of 200 MeV/u and 300 MeV/u extracted with 300 ms pulse duration and applied to the screens. The particle intensity of the ion beam was varied from 10{sup 4} to 10{sup 9} particles per pulse. The screens were irradiated with typically 40 beam pulses and the scintillation light was captured using a CCD camera followed by characterization of the beam spot. The radiation hardness of the screens was estimated with high intensity Uranium ion irradiation. In the study, a linear light output for 5 orders of magnitude of particle intensities was observed from sensitive scintillators and ceramic screens such as Al{sub 2}O{sub 3}:Cr and Al{sub 2}O{sub 3}. The highest light output was recorded by CsI:Tl and the lowest one by Herasil. At higher beam intensity saturation of light output was noticed from Y and Mg doped ZrO{sub 2} screens. The light output from the screen depends not only on the particle intensity but also on the ion species used for irradiation. The light yield (i.e. the light intensity normalised to the energy deposition in the material by the ion) is calculated from the experimental data for each ion beam setting. It is shown that the light yield for light ions is about a factor 2 larger than the one of heavy ions. The image widths recorded exhibit a dependence on the screens material and differences up to 50 % were registered. On radiation stability analysis with high particle intensity of Uranium ions of about 6 x 10{sup 8} ppp, a stable performance in light output and image reproduction was documented from Al

  12. The Deflection of Charged Particles in an Electric Dodecapole Field

    Energy Technology Data Exchange (ETDEWEB)

    Seely, D. G.; Chalut, K.; Thompson, J. S.; Kvale, T. J.

    1997-10-10

    The properties of an ion-optical device consisting of twelve long parallel rods placed equidistantly on a circle are briefly reviewed. The use of this device in its dodecapole configuration to deflect ions in a plane perpendicular to the axis of the dodecapole is discussed. Results of trajectory computations made with the SIMION ion-optics computer program demonstrate that the device works remarkably well in separating the constituents of a multiply-charged ion beam. The use of this device to merge an ion beam with an optical beam is proposed.

  13. [Pliability and deflection of diagnostic catheters].

    Science.gov (United States)

    Pelyhe, Liza; Bognár, Eszter

    2014-09-28

    The cardiac catheter is an intravascular catheter, which is introduced or implanted into the heart for diagnostic or therapeutic reasons. The catheters may break or king during their introduction and/or removal. The aim of the authors was to study the pliability of two catheters with the same material but different diameters according to the Food and Drug Administration's recommendation. The bending points, diameter decrease, deflection, and their correlation and dependence on the distance from the tip, as well as the influence of the initial diameter of the catheters were determined. The bending of catheters was performed on 9 bending points (120-280 mm from the tip by 20 mm) on 16 gauges with different radius (10-2.5 mm by 0.5 mm). A linear dependency between the diameter decrease and deflection was observed, which was independent from the placement of the measurement in both catheters examined. The larger initial diameter had significant (p = 0.05) greater diameter decrease than the smaller, but the curves characteristic of the diameter decrease and deflection were similar. The applied method seems to be useful for the examination of weak points of cardiac catheters.

  14. Measurements of the luminosity and normalised beam-induced background using the CMS Fast Beam Condition Monitor

    CERN Document Server

    Odell, Nathaniel Jay

    2012-01-01

    The CMS Beam Conditions and Radiation Monitoring system (BRM) is installed to protect the CMS detector from high beam losses and to provide feedback to the LHC and CMS on the beam conditions. The Fast Beam Condition Monitor (BCM1F), one of the sub-detectors in the BRM system, is installed inside the pixel volume close to the beam pipe and consists of two planes of 4 modules each located 1.8 m away from the IP, on both ends. It uses single-crystal CVD diamond sensors, radiation hard front-end electronics and an optical transmission of the signal. It is designed for single particle rate measurements, detecting both machine induced beam background and collision products on a bunch-by-bunch basis. Presented is the implementation of the normalized online beam-induced background measurement and the online instantaneous luminosity measurement. The method for determining the luminosity from the measured rates, including the absolute calibration using the Van der Meer scan, and the measurement performance will be d...

  15. Deflecting another Tunguska

    Science.gov (United States)

    Williamson, Mark

    2009-07-01

    In October 2008 astronomers in the US discovered an asteroid measuring a few metres across that appeared to be on a collision course for Earth. The astronomers, based at the Catalina Sky Survey near Tucson, Arizona, calculated that it would impact the atmosphere in just 19 hours. Sure enough, the asteroid - named 2008 TC3 - hit the atmosphere over northern Sudan early the next morning, producing what NASA called "a brilliant fireball", with an estimated energy equivalent to a kilotonne of TNT.

  16. Analysis of the Influence of Fibre Diameter on Wirescanner Beam Profile Measurements

    CERN Document Server

    King, Quentin

    1988-01-01

    It is often important to be able to measure beam profiles in regions where the beam size is very small. Following concern that the profile measurement might be affected by having a beam size of the same order as the diameter of the wirescanner fibre, the effect was analysed numerically, and the results are presented.

  17. Beam Measurements of a CLOUD (Cosmics Leaving OUtdoor Droplets) Chamber

    CERN Document Server

    Kirkby, Jasper

    2001-01-01

    A striking correlation has recently been observed between global cloud cover and the flux of incident cosmic rays. The effect of natural variations in the cosmic ray flux is large, causing estimated changes in the Earth's energy radiation balance that are comparable to those attributed to greenhouse gases from the burning of fossil fuels since the Industrial Revolution. However a direct link between cosmic rays and cloud formation has not been unambiguously established. We therefore propose to experimentally measure cloud (water droplet) formation under controlled conditions in a test beam at CERN with a CLOUD chamber, duplicating the conditions prevailing in the troposphere. These data, which have never been previously obtained, will allow a detailed understanding of the possible effects of cosmic rays on clouds and confirm, or otherwise, a direct link between cosmic rays, global cloud cover and the Earth's climate. The measurements will, in turn, allow more reliable calculations to be made of the residual e...

  18. Method and apparatus for measuring properties of particle beams using thermo-resistive material properties

    Science.gov (United States)

    Degtiarenko, Pavel V.; Dotson, Danny Wayne

    2007-10-09

    A beam position detector for measuring the properties of a charged particle beam, including the beam's position, size, shape, and intensity. One or more absorbers are constructed of thermo-resistive material and positioned to intercept and absorb a portion of the incoming beam power, thereby causing local heating of each absorber. The local temperature increase distribution across the absorber, or the distribution between different absorbers, will depend on the intensity, size, and position of the beam. The absorbers are constructed of a material having a strong dependence of electrical resistivity on temperature. The beam position detector has no moving parts in the vicinity of the beam and is especially suited to beam areas having high ionizing radiation dose rates or poor beam quality, including beams dispersed in the transverse direction and in their time radio frequency structure.

  19. Observations And Measurements of Anomalous Hollow Electron Beams in a Storage Ring

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Y.K.; Li, J.; /Duke U.; Wu, J.; /SLAC

    2006-02-06

    Anomalous hollow electron beams have been recently observed in the Duke storage ring. With a single bunch beam in a lattice with a negative chromaticity, a hollow beam can be created. This beam consists of a solid core beam inside and a large ring beam outside. In this paper, we report the measurements of the hollow beam phenomenon, including its distinct image pattern and spectrum signature, and its evolution with time. By capturing the post-instability bursting beam, the hollow beam is a unique model system for studying transverse instabilities, in particular, the interplay of the wakefield and lattice nonlinearity. The hollow beam can also be used as a tool to study linear and nonlinear particle dynamics in the storage ring.

  20. Measuring the self-healing of the spatially inhomogeneous states of polarization of vector Bessel beams

    CSIR Research Space (South Africa)

    Milione, G

    2015-02-01

    Full Text Available We experimentally measured the self-healing of the spatially inhomogeneous states of polarization of vector Bessel beams. Radially and azimuthally polarized vector Bessel beams were experimentally generated via a digital version of Durnin's method...

  1. Beam Spot Measurement on a 400 keV Electron Accelerator

    DEFF Research Database (Denmark)

    Miller, Arne

    1979-01-01

    A line probe is used to measure the beam spot radius and beam divergence at a 400 keV ICT electron accelerator, and a method is shown for reducing the line probe data in order to get the radial function.......A line probe is used to measure the beam spot radius and beam divergence at a 400 keV ICT electron accelerator, and a method is shown for reducing the line probe data in order to get the radial function....

  2. Investigations in CO2 laser beam caustics measuring techniques

    DEFF Research Database (Denmark)

    Olsen, Flemming Ove; Bagger, Claus

    2004-01-01

    The performance of an industrial laser is very much depending upon the characteristics of the laser beam. The ISO standards 11146 and 11154 which are describing test methods for laser beam parameters have been approved.......The performance of an industrial laser is very much depending upon the characteristics of the laser beam. The ISO standards 11146 and 11154 which are describing test methods for laser beam parameters have been approved....

  3. Investigations in CO2 laser beam caustics measuring techniques

    DEFF Research Database (Denmark)

    Olsen, Flemming Ove; Bagger, Claus

    2004-01-01

    The performance of an industrial laser is very much depending upon the characteristics of the laser beam. The ISO standards 11146 and 11154 which are describing test methods for laser beam parameters have been approved.......The performance of an industrial laser is very much depending upon the characteristics of the laser beam. The ISO standards 11146 and 11154 which are describing test methods for laser beam parameters have been approved....

  4. Linac3 LEBT beam measurements during the 2014-2015 Argon ion run

    CERN Document Server

    Bellodi, Giulia; Maintrot, Marc; Toivanen, Ville Aleksi; CERN. Geneva. ATS Department

    2016-01-01

    Between Spring 2014 and Spring 2015, LINAC3 delivered a beam of Argon ions. A campaign of beam studies was launched with the aim of better understanding the present limitations in the machine performance in the framework of the requested intensity goals as defined by the LHC Injectors Upgrade project. Measurements were mostly focused on beam characterization in the low energy part of Linac3 (LEBT), where performance in operation is mostly limited (in terms of beam transmission). Systematic quadrupole scans provided indirect measurement of the beam transverse emittance and were used as input to improve and refine the accelerator and beam description parameters used in simulations. IBSimu studies of beam formation and extraction at the source were interfaced with particle tracking with the 3D code PATH, and the resulting predictions found good validation in the beam measurements taken during this campaign.

  5. A fast chopper for medium energy beams

    Energy Technology Data Exchange (ETDEWEB)

    Madrak, R. [Fermilab; Wildman, D. [Fermilab

    2014-10-30

    The key elements have been constructed for a fast chopper system capable of removing single 2.5 MeV proton bunches spaced at 325 MHz. The average chopping rate is ~ 1 MHz. The components include a pulse delaying microstrip structure for deflecting the beam, high voltage (1.2 kV) fast (ns rise time) pulsers, and an associated wideband combiner. Various designs for the deflecting structures have been studied. Measurements of the microstrip structures' coverage factors and pulse shapes are presented.

  6. Deflection determination of concrete structures considering nonlinearity based on long-gauge strain sensors

    Science.gov (United States)

    Hong, Wan; Lv, Kui; Li, Bing; Jiang, Yuchen; Hu, Xiamin; Qu, Qizhong

    2017-10-01

    Deflection determination of concrete structures using distributed long-gauge strain sensors is investigated in this paper. Firstly, the relationship between deflection and distributed long-gauge strain of concrete beams is presented, and the method is independent of external load and takes account of structural nonlinearity. The deflection distribution along the span of a beam-like structure can be predicted from strain response for the whole process of loading (elastic stage, concrete cracking stage and steel yielding stage). Secondly, experiment of a reinforced concrete beam has been conducted to verify the accuracy of the method. Experimental results show that the relative error between the estimated and actual deflection can be controlled within about 5% while the error can reach up to about 70% if structural nonlinearity is not considered. Finally, the influence of error of material parameters and sensor gauge length on deflection estimation has been analyzed. The error of concrete compression strength has a limited influence on deflection prediction while the contribution of tensile concrete should be considered before concrete cracking. The error of area of tensile bars will affect the deflection accuracy after concrete cracking.

  7. Plunger lifetime measurements after Coulomb excitation at intermediate beam energies

    Energy Technology Data Exchange (ETDEWEB)

    Hackstein, Matthias; Dewald, Alfred; Fransen, Christoph; Ilie, Gabriela; Jolie, Jan; Melon, Barbara; Pissulla, Thomas; Rother, Wolfram; Zell, Karl-Oskar [University of Cologne (Germany); Petkov, Pavel [University of Cologne (Germany); INRNE (Bulgaria); Chester, Aaron; Adrich, Przemyslaw; Bazin, Daniel; Bowen, Matt; Gade, Alexandra; Glasmacher, Thomas; Miller, Dave; Moeller, Victoria; Starosta, Krzysztof; Stolz, Andreas; Vaman, Constantin; Voss, Philip; Weissharr, Dirk [Michigan State Univerity (United States); Moeller, Oliver [TU Darmstadt (Germany)

    2008-07-01

    Two recoil-distance-doppler-shift (RDDS) experiments were performed at the NSCL/MSU using Coulomb excitations of the projectile nuclei {sup 110}Pd, {sup 114}Pd at beam energies of 54 MeV/u in order to investigate the evolution of deformation of neutron rich paladium isotopes. The experimental set-up consisted of a dedicated plunger device, developed at the University of Cologne, the SEGA Ge-array and the S800 spectrometer. Lifetimes of the 2{sub 1}{sup +}-states in {sup 110}Pd and {sup 114}Pd were derived from the analysis of the {gamma}-line-shapes as well as from the measured decay-curves. Special features of the data analysis, e.g. features originating from the very high recoil velocities, are discussed.

  8. Basic oscillation measurables in the neutrino pair beam

    Directory of Open Access Journals (Sweden)

    T. Asaka

    2016-09-01

    Full Text Available It was recently shown that the neutrino-pair emission may occur with large rates, their energy being extended to GeV region, if appropriate heavy ions are circulated in a quantum state of mixture. In the present work it is further demonstrated that the vector current contribution of neutrino interaction with electrons in ion, not necessarily suppressed in high atomic number ions, gives rise to the oscillating component, even when a single neutrino is detected alone. On the other hand, the single neutrino detection in Z-boson decay does not show the oscillating component, as known for some time. CP violation measurements in the neutrino pair beam may become a possibility, along with determination of mass hierarchical patterns.

  9. Direct-current proton-beam measurements at Los Alamos

    Energy Technology Data Exchange (ETDEWEB)

    Sherman, J.; Stevens, R.R.; Schneider, J.D.; Zaugg, T.

    1994-08-01

    Recently, a CW proton accelerator complex was moved from Chalk River Laboratories (CRL) to Los Alamos National Laboratory. This includes a 50-keV dc proton injector with a single-solenoid low-energy beam transport system (LEBT) and a CW 1.25-MeV, 267-MHz radiofrequency quadrupole (RFQ). The move was completed after CRL had achieved 55-mA CW operation at 1.25 MeV using 250-kW klystrode tubes to power the RFQ. These accelerator components are prototypes for the front end of a CW linac required for an accelerator-driven transmutation linac, and they provide early confirmation of some CW accelerator components. The injector (ion source and LEBT) and emittance measuring unit are installed and operational at Los Alamos. The dc microwave ion source has been operated routinely at 50-keV, 75-mA hydrogen-ion current. This ion source has demonstrated very good discharge and H{sub 2} gas efficiencies, and sufficient reliability to complete CW RFQ measurements at CRL. Proton fraction of 75% has been measured with 550-W discharge power. This high proton fraction removes the need for an analyzing magnet. Proton LEBT emittance measurements completed at Los Alamos suggest that improved transmission through the RFQ may be achieved by increasing the solenoid focusing current. Status of the final CW RFQ operation at CRL and the installation of the RFQ at Los Alamos is given.

  10. Elevator deflections on the icing process

    Science.gov (United States)

    Britton, Randall K.

    1990-01-01

    The effect of elevator deflection of the horizontal stabilizer for certain icing parameters is investigated. Elevator deflection can severely change the lower and upper leading-edge impingement limits, and ice can accrete on the elevator itself. Also, elevator deflection had practically no effect on the maximum local collection efficiency. It is shown that for severe icing conditions (large water droplets), elevator deflections that increase the projected height of the airfoil can significantly increase the total collection efficiency of the airfoil.

  11. Beam Commissioning and Performance Characterisation of the LHC Beam Dump Kicker Systems

    CERN Document Server

    Uythoven, J; Ducimetière, L; Goddard, B; Kain, V; Magnin, N

    2010-01-01

    The LHC beam dump system was commissioned with beam in 2009. This paper describes the operational experience with the kicker systems and the tests and measurements to qualify them for operation. The kicker performance was characterized with beam by measurements of the deflection angles, using bunches extracted at different times along the kicker sweep. The kicker performance was also continuously monitored for each dump with measurement and analysis of all kick pulses, allowing diagnostic of errors and of long-term drifts. The results are described and compared to the expectations.

  12. Characterisation of a Mechanical Deflection Sensor

    CSIR Research Space (South Africa)

    Miyambo, M

    2012-10-01

    Full Text Available ). REFERENCES Snyman, I.M. and Reinecke, J.D. 2006. Measuring the impulse from an explosive charge, Ballistics Symposium South Africa, Denel-OTB, Bredasdorp, 15?16 Aug 2006. Miyambo, M.E. and Pandelani, T. 2012. The Mechanical Deflection Sensor Test... Mechanical Defl ection Sensor M MIYAMBO AND T PANDELANI CSIR Defence, Peace, Safety and Security, PO Box 395, Pretoria, South Africa, 0001 Email: mmiyambo@csir.co.za ? www.csir.co.za INTRODUCTION The CSIR Defence, Peace, Safety and Security (DPSS...

  13. In vacuum diamond sensor scanner for beam halo measurements in the beam line at the KEK Accelerator Test Facility

    CERN Document Server

    Liu, Shan; Cornebise, Patrick; Faus-Golfe, Angeles; Fuster-Martínez, Nuria; Griesmayer, Erich; Guler, Hayg; Kubytskyi, Viacheslav; Sylvia, Christophe; Toshiaki, Tauchi; Terunuma, Nobuhiro; Bambade, Philip

    2015-01-01

    The investigation of beam halo transverse distributions is important for the understanding of beam losses and the control of backgrounds in Future Linear Colliders (FLC). A novel in vacuum diamond sensor (DSv) scanner with four strips has been designed and developed for the investigation of the beam halo transverse distributions and also for the diagnostics of Compton recoil electrons after the interaction point (IP) of ATF2, a low energy (1.3 GeV) prototype of the final focus system for the ILC and CLIC linear collider projects. Using the DSv, a dynamic range of $\\sim10^6$ has been successfully demonstrated and confirmed for the first time by simultaneous beam core ($\\sim10^9$ electrons) and beam halo ($\\sim10^3$ electrons) measurements at ATF2. This report presents the characterization, performance studies and tests of the diamond sensors using an $\\alpha$ source as well as using the electron beams at PHIL, a low energy ($< 10$ MeV) photo-injector at LAL, and at ATF2. First beam halo measurement results ...

  14. Investigation of the phase space distribution of electron bunches at the FLASH-linac using a transverse deflecting structure

    Energy Technology Data Exchange (ETDEWEB)

    Roehrs, M.

    2008-06-15

    The operation of a high-gain free-electron laser (FEL) puts stringent demands on the peak current, transverse emittance and energy spread of the electron beam. At the Free Electron Laser in Hamburg (FLASH), a transverse deflecting structure (TDS) has been installed to investigate these electron beam parameters. The radio-frequency electromagnetic field in the TDS is utilized to deflect the beam electrons vertically as a function of time so that the charge distribution in the longitudinal-horizontal plane can be imaged with optical transition radiation screens. Using this technique, the single-bunch current profile was measured with an unprecedented resolution of about 10 {mu}m (30 fs) under FEL operating conditions. A precise single-shot measurement of the energy distribution along a bunch was accomplished by using the TDS in combination with an energy spectrometer. Appropriate variations of the focal strengths of quadrupole magnets allowed for the measurement of the horizontal emittance as a function of the longitudinal position within a bunch (slice emittance) with a longitudinal resolution in the order of 10 {mu}m. While the slice emittance in the peak current region was measured to be significantly larger than deduced from properties of the FEL radiation, tomographic methods revealed a bunch region of small horizontal emittance and high current. The observed increase in slice emittance in the peak current region was found to be caused by coherent emission of synchrotron radiation within bending magnets. (orig.)

  15. Measuring the polarization of a rapidly precessing deuteron beam

    Science.gov (United States)

    Bagdasarian, Z.; Bertelli, S.; Chiladze, D.; Ciullo, G.; Dietrich, J.; Dymov, S.; Eversmann, D.; Fanourakis, G.; Gaisser, M.; Gebel, R.; Gou, B.; Guidoboni, G.; Hejny, V.; Kacharava, A.; Kamerdzhiev, V.; Lehrach, A.; Lenisa, P.; Lorentz, B.; Magallanes, L.; Maier, R.; Mchedlishvili, D.; Morse, W. M.; Nass, A.; Oellers, D.; Pesce, A.; Prasuhn, D.; Pretz, J.; Rathmann, F.; Shmakova, V.; Semertzidis, Y. K.; Stephenson, E. J.; Stockhorst, H.; Ströher, H.; Talman, R.; Thörngren Engblom, P.; Valdau, Yu.; Weidemann, C.; Wüstner, P.

    2014-05-01

    This paper describes a time-marking system that enables a measurement of the in-plane (horizontal) polarization of a 0.97-GeV/c deuteron beam circulating in the Cooler Synchrotron (COSY) at the Forschungszentrum Jülich. The clock time of each polarimeter event is used to unfold the 120-kHz spin precession and assign events to bins according to the direction of the horizontal polarization. After accumulation for one or more seconds, the down-up scattering asymmetry can be calculated for each direction and matched to a sinusoidal function whose magnitude is proportional to the horizontal polarization. This requires prior knowledge of the spin tune or polarization precession rate. An initial estimate is refined by resorting the events as the spin tune is adjusted across a narrow range and searching for the maximum polarization magnitude. The result is biased toward polarization values that are too large, in part because of statistical fluctuations but also because sinusoidal fits to even random data will produce sizable magnitudes when the phase is left free to vary. An analysis procedure is described that matches the time dependence of the horizontal polarization to templates based on emittance-driven polarization loss while correcting for the positive bias. This information will be used to study ways to extend the horizontal polarization lifetime by correcting spin tune spread using ring sextupole fields and thereby to support the feasibility of searching for an intrinsic electric dipole moment using polarized beams in a storage ring. This paper is a combined effort of the Storage Ring EDM collaboration and the JEDI collaboration.

  16. Measurements of an ion beam diameter extracted into air through a glass capillary

    Energy Technology Data Exchange (ETDEWEB)

    Fujita, Natsuko, E-mail: fujita.natsuko@jaea.go.jp [Graduate School of Humanities and Sciences, Nara Women’s University, Nara, 630 8506 (Japan); Yamaki, Atsuko [Graduate School of Humanities and Sciences, Nara Women’s University, Nara, 630 8506 (Japan); Ishii, Kunikazu; Ogawa, Hidemi [Department of Physics, Nara Women’s University, Nara, 630 8506 (Japan)

    2013-11-15

    To establish techniques for in-air materials analysis using a glass capillary, we studied the beam distribution extracted in air as a function of the distance between the exit of the capillary and the target. We measured three-dimensional intensity distributions of the extracted beams, and compared the observed results with the model calculation. The comparison showed that the glass capillary technique is designed to reduce a divergence of the beam extracted into the air by a beam-focusing effect.

  17. Beam Parameter Measurement and Control at the SNS Target

    CERN Document Server

    Plum, Michael; McManamy, Tom

    2005-01-01

    The spallation neutron production target at the SNS facility is designed for 1.4 MW beam power. Both beam position and profile must be carefully controlled within narrow margins to avoid damage to the target. The position must be within 2 mm of the target center, and 90% of the beam must be within the nominal 70 mm x 200 mm spot size, without exceeding 0.18 A/m2

  18. Space Charge Correction on Emittance Measurement of Low Energy Electron Beams

    Energy Technology Data Exchange (ETDEWEB)

    Treado, Colleen J.; /Massachusetts U., Amherst

    2012-09-07

    The goal of any particle accelerator is to optimize the transport of a charged particle beam along a set path by confining the beam to a small region close to the design trajectory and directing it accurately along the beamline. To do so in the simplest fashion, accelerators use a system of magnets that exert approximately linear electromagnetic forces on the charged beam. These electromagnets bend the beam along the desired path, in the case of bending magnets, and constrain the beam to the desired area through alternating focusing and defocusing effects, in the case of quadrupole magnets. We can model the transport of such a beam through transfer matrices representing the actions of the various beamline elements. However, space charge effects, produced from self electric fields within the beam, defocus the beam and must be accounted for in the calculation of beam emittance. We present below the preliminary results of a MATLAB code built to model the transport of a charged particle beam through an accelerator and measure the emittance under the influence of space charge effects. We demonstrate the method of correctly calculating the emittance of a beam under space charge effects using a least square fit to determine the initial properties of the beam given the beam size measured at a specific point after transport.

  19. LogAmp electronics and optical transmission for the new SPS beam position measurement system

    Science.gov (United States)

    Bogey, T.; Deplano, C.; Gonzalez, J. L.; Savioz, J. J.

    2013-12-01

    A new front-end board is under development for the CERN SPS Multi ORbit Position System (MOPOS). Based on logarithmic amplifiers, it measures the beam position over a large dynamic range of beam intensities and resolves the multi-batch structure of the SPS beams. Analogue data are digitized at 10 MS/s, packed in frames by an FPGA and on every turn sent to the readout board, via a 2.4 Gb/s optical transmission link. A first prototype has been successfully tested with several SPS beams. This paper presents an overall description of the system and its capabilities highlighted by the first beam measurements.

  20. LogAmp electronics and Optical Transmission for the new SPS Beam Position Measurement System

    CERN Document Server

    Deplano, C; Gonzalez, J L; Savioz, J J

    2013-01-01

    A new front-end board is under development for the CERN SPS Multi ORbit Position System (MOPOS). Based on logarithmic amplifiers, it measures the beam position over a large dynamic range of beam intensities and resolves the multi-batch structure of the SPS beams. Analogue data are digitized at 10 MS/s, packed in frames by an FPGA and on every turn sent to the readout board, via a 2.4 Gb/s optical transmission link. A first prototype has been successfully tested with several SPS beams. This paper presents an overall description of the system and its capabilities highlighted by the first beam measurements.

  1. Non-perturbative measurement of low-intensity charged particle beams

    Science.gov (United States)

    Fernandes, M.; Geithner, R.; Golm, J.; Neubert, R.; Schwickert, M.; Stöhlker, T.; Tan, J.; Welsch, C. P.

    2017-01-01

    Non-perturbative measurements of low-intensity charged particle beams are particularly challenging to beam diagnostics due to the low amplitude of the induced electromagnetic fields. In the low-energy antiproton decelerator (AD) and the future extra low energy antiproton rings at CERN, an absolute measurement of the beam intensity is essential to monitor the operation efficiency. Superconducting quantum interference device (SQUID) based cryogenic current comparators (CCC) have been used for measuring slow charged beams in the nA range, showing a very good current resolution. But these were unable to measure fast bunched beams, due to the slew-rate limitation of SQUID devices and presented a strong susceptibility to external perturbations. Here, we present a CCC system developed for the AD machine, which was optimised in terms of its current resolution, system stability, ability to cope with short bunched beams, and immunity to mechanical vibrations. This paper presents the monitor design and the first results from measurements with a low energy antiproton beam obtained in the AD in 2015. These are the first CCC beam current measurements ever performed in a synchrotron machine with both coasting and short bunched beams. It is shown that the system is able to stably measure the AD beam throughout the entire cycle, with a current resolution of 30 {nA}.

  2. Measurement of Velocity Distribution in Atomic Beam by Diode Laser with Narrow Line width

    Institute of Scientific and Technical Information of China (English)

    CHEN Jingbiao; WANG Fengzhi; YANG Donghai; WANG YiQiu

    2001-01-01

    In this paper, by using the detecting laser beam interacts with the atomic beam at a sharp angle and the Doppler frequency shift effect, the velocity distribution in cesium atomic beam is measured with a diode laser of narrow linewidth of 1 MHz. The effects of the atomic natural line width and cycling transition detecting factor on the measured results have been analyzed. Finally, the measured results have been compared with the theoretical calculation.

  3. First Measurement of Beam-Recoil Observables Cx and Cz

    Energy Technology Data Exchange (ETDEWEB)

    R. Bradford; R.A. Schumacher; G. Adams; M.J. Amaryan; P. Ambrozewicz; E. Anciant; M. Anghinolfi; B. Asavapibhop; G. Asryan; G. Audit; H. Avakian; H. Bagdasaryan; N. Baillie; J.P. Ball; N.A. Baltzell; S. Barrow; V. Batourine; M. Battaglieri; K. Beard; I. Bedlinskiy; M. Bektasoglu; M. Bellis; N. Benmouna; B.L. Berman; N. Bianchi; A.S. Biselli; B.E. Bonner; S. Bouchigny; S. Boiarinov; D. Branford; W.J. Briscoe; W.K. Brooks; S. B¨ultmann; V.D. Burkert; C. Butuceanu; J.R. Calarco; S.L. Careccia; D.S. Carman; B. Carnahan; S. Chen; P.L. Cole; A. Coleman; P. Collins; P. Coltharp; D. Cords; † P. Corvisiero; D. Crabb; H. Crannell; V. Crede; J.P. Cummings; R. De Masi; E. De Sanctis; R. De Vita; P.V. Degtyarenko; H. Denizli; L. Dennis; A. Deur; K.V. Dharmawardane; R. Dickson; C. Djalali; G.E. Dodge; J. Donnelly; D. Doughty; P. Dragovitsch; M. Dugger; S. Dytman; O.P. Dzyubak; H. Egiyan; ; K.S. Egiyan; L. El Fassi; L. Elouadrhiri; A. Empl; P. Eugenio; R. Fatemi; G. Fedotov; G. Feldman; R.J. Feuerbach; T.A. Forest; H. Funsten; M. Garcon; G. Gavalian; ; G.P. Gilfoyle; K.L. Giovanetti; F.X. Girod; J.T. Goetz; A. Gonenc; R.W. Gothe; K.A. Griffioen; M. Guidal; M. Guillo; N. Guler; L. Guo; V. Gyurjyan; C. Hadjidakis; K. Hafidi; H. Hakobyan; R.S. Hakobyan; J. Hardie; D. Heddle; F.W. Hersman; K. Hicks; I. Hleiqawi; M. Holtrop; J. Hu; M. Huertas; C.E. Hyde-Wright; Y. Ilieva; D.G. Ireland; B.S. Ishkhanov; E.L. Isupov; M.M. Ito; D. Jenkins; H.S. Jo; K. Joo; H.G. Juengst; N. Kalantarians; J.D. Kellie; M. Khandaker; K.Y. Kim; K. Kim; W. Kim; A. Klein; F.J. Klein; M. Klusman; M. Kossov; L.H. Kramer; V. Kubarovsky; J. Kuhn; S.E. Kuhn; S.V. Kuleshov; J. Lachniet; J.M. Laget; J. Langheinrich; D. Lawrence; A.C.S. Lima; K. Livingston; H.Y. Lu; K. Lukashin; M. MacCormick; J.J. Manak; C. Marchand; N. Markov; S. McAleer; B. McKinnon; J.W.C. McNabb; B.A. Mecking; M.D. Mestayer; C.A. Meyer; T. Mibe; K. Mikhailov; M. Mirazita; R. Miskimen; V. Mokeev; K. Moriya; S.A. Morrow; M. Moteabbed; V. Muccifora; J. Mueller; G.S. Mutchler; P. Nadel-Turonski; J. Napolitano; R. Nasseripour; N. Natasha; S. Niccolai; G. Niculescu; I. Niculescu; B.B. Niczyporuk; M.R. Niroula; R.A. Niyazov; M. Nozar; G.V. O’Rielly; M. Osipenko; A.I. Ostrovidov; K. Park; E. Pasyuk; C. Paterson; S.A. Philips; J. Pierce; N. Pivnyuk; D. Pocanic; O. Pogorelko; E. Polli; I. Popa; S. Pozdniakov; B.M. Preedom; J.W. Price; Y. Prok; D. Protopopescu; L.M. Qin; B.P. Quinn; B.A. Raue; G. Riccardi; G. Ricco; M. Ripani; B.G. Ritchie; F. Ronchetti; G. Rosner; P. Rossi; D. Rowntree; P.D. Rubin; F. Sabatie; J. Salamanca; C. Salgado; J.P. Santoro; ; V. Sapunenko; V.S. Serov; A. Shafi; Y.G. Sharabian; J. Shaw; N.V. Shvedunov; S. Simionatto; A.V. Skabelin; E.S. Smith; L.C. Smith; D.I. Sober; D. Sokhan; M. Spraker; A. Stavinsky; S.S. Stepanyan; S. Stepanyan; B.E. Stokes; P. Stoler; I.I. Strakovsky; S. Strauch; M. Taiuti; S. Taylor; D.J. Tedeschi; U. Thoma; R. Thompson; A. Tkabladze; S. Tkachenko; L. Todor; C. Tur; M. Ungaro; M.F. Vineyard; A.V. Vlassov; K. Wang; D.P. Watts; L.B. Weinstein; H. Weller; D.P. Weygand; M. Williams; E. Wolin; M.H. Wood; A. Yegneswaran; J. Yun; L. Zana; J. Zhang; B. Zhao; and Z.W. Zhao

    2007-03-01

    Spin transfer from circularly polarized real photons to recoiling hyperons has been measured for the reactions $\\vec\\gamma + p \\to K^+ + \\vec\\Lambda$ and $\\vec\\gamma + p \\to K^+ + \\vec\\Sigma^0$. The data were obtained using the CLAS detector at Jefferson Lab for center-of-mass energies $W$ between 1.6 and 2.53 GeV, and for $-0.85<\\cos\\theta_{K^+}^{c.m.}< +0.95$. For the $\\Lambda$, the polarization transfer coefficient along the photon momentum axis, $C_z$, was found to be near unity for a wide range of energy and kaon production angles. The associated transverse polarization coefficient, $C_x$, is smaller than $C_z$ by a roughly constant difference of unity. Most significantly, the {\\it total} $\\Lambda$ polarization vector, including the induced polarization $P$, has magnitude consistent with unity at all measured energies and production angles when the beam is fully polarized. For the $\\Sigma^0$ this simple phenomenology does not hold. All existing hadrodynamic models are in poor agreement with these results.

  4. Measuring Broadband IR Irradiance in the Direct Solar Beam (Poster)

    Energy Technology Data Exchange (ETDEWEB)

    Reda, I.; Konings, J.; Xie, Y.; Dooraghi, M.; Sengupta, M.

    2015-03-01

    Solar and atmospheric science radiometers, e.g. pyranometers, pyrheliometers, and photovoltaic cells are calibrated with traceability to a consensus reference, which is maintained by Absolute Cavity Radiometers (ACRs). The ACR is an open cavity with no window, developed to measure extended broadband direct solar irradiance beyond the ultraviolet and infrared bands below and above 0.2 micrometers and 50 micrometers, respectively. On the other hand, pyranometers and pyrheliometers are developed to measure broadband shortwave irradiance from approximately 0.3 micrometers to 3 micrcometers, while the present photovoltaic cells are limited to approximately 0.3 micrometers to 1 micrometers. The broadband mismatch of ACR versus such radiometers causes discrepancy in radiometers' calibration methods that has not been discussed or addressed in the solar and atmospheric science literature. Pyrgeometers are also used for solar and atmospheric science applications and calibrated with traceability to consensus reference, yet calibrated during nighttime only, because no consensus reference has yet been established for the daytime longwave irradiance. This poster shows a method to measure the broadband IR irradiance in the direct solar beam from 3 micrometers to 50 micrometers, as first step that might be used to help develop calibration methods to address the mismatch between broadband ACR and shortwave radiometers, and the lack of a daytime reference for pyrgeometers. The irradiance was measured from sunrise to sunset for 5 days when the sun disk was cloudless; the irradiance varied from approximately 1 Wm-2 to 16 Wm-2 for solar zenith angle from 80 degres to 16 degrees respectively; estimated uncertainty is 1.5 Wm-2.

  5. Measuring Broadband IR Irradiance in the Direct Solar Beam (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Reda, I.

    2015-03-01

    Solar and atmospheric science radiometers, e.g. pyranometers, pyrheliometers, and photovoltaic cells are calibrated with traceability to a consensus reference, which is maintained by Absolute Cavity Radiometers (ACRs). The ACR is an open cavity with no window, developed to measure extended broadband direct solar irradiance beyond the ultraviolet and infrared bands below and above 0.2 um and 50 um, respectively. On the other hand, pyranometers and pyrheliometers are developed to measure broadband shortwave irradiance from approximately 0.3 um to 3 um, while the present photovoltaic cells are limited to approximately 0.3 um to 1 um. The broadband mismatch of ACR versus such radiometers causes discrepancy in radiometers' calibration methods that has not been discussed or addressed in the solar and atmospheric science literature. Pyrgeometers are also used for solar and atmospheric science applications and are calibrated with traceability to consensus reference, yet are calibrated during nighttime only, because no consensus reference has yet been established for the daytime longwave irradiance. This poster shows a method to measure the broadband IR irradiance in the direct solar beam from 3 um to 50 um, as a first step that might be used to help develop calibration methods to address the mismatch between broadband ACR and shortwave radiometers, and the lack of a daytime reference for pyrgeometers. The irradiance was measured from sunrise to sunset for 5 days when the sun disk was cloudless; the irradiance varied from approximately 1 Wm-2 to 16 Wm-2 for solar zenith angle from 80 degrees to 16 degrees respectively; estimated uncertainty is 1.5 Wm-2.

  6. Subtraction of beam-associated background in R measurement

    CERN Document Server

    Yan Wen Biao; Chi Shao Peng; Huang Guang Shun; Zhang Lei; Zhang Li; Zhao Zheng Gu; Dai Yu Mei; Li Hui; Wang Zhi Yong

    2002-01-01

    Using R scan data collected at BES II detector, the authors study the character of beam-associated background. The authors use the method of f factor and the fitting of event vertices to subtract the residual beam-associated background. The difference between the R values obtained by using these two methods is between 0.3% and 2.3%

  7. Beam-quality measurements using a spatial light modulator

    CSIR Research Space (South Africa)

    Schulze, C

    2012-11-01

    Full Text Available depicts the experimen- tal setup, which is fairly simple, consisting only of the beam source (helium neon laser, λ � 633 nm, 2 mW), whose beam was expanded to approximate a plane wave (diameter 10 mm), the SLM (Holoeye PLUTO, reflective liquid crystal...

  8. Measurement of the polarisation of a high energy muon beam

    Energy Technology Data Exchange (ETDEWEB)

    Adeva, B.; Ahmad, S.; Arvidson, A.; Badelek, B.; Ballintijn, M.K.; Bardin, G.; Baum, G.; Berglund, P.; Betev, L.; Bird, I.G.; Birsa, R.; Bjoerkholm, P.; Bonner, B.E.; Botton, N. de; Boutemeur, M.; Bradamante, F.; Bressan, A.; Bruell, A.; Buchanan, J.; Bueltmann, S.; Burtin, E.; Cavata, C.; Chen, J.P.; Clement, J.; Clocchiatti, M.; Corcoran, M.D.; Crabb, D.; Cranshaw, J.; Cuhadar, T.; Dalla Torre, S.; Dantzig, R. van; Day, D.; Demolis, J.M.; Dhawan, S.; Dulya, C.; Dupont, J.; Dyring, A.; Eichblatt, S.; Faivre, J.C.; Fasching, D.; Feinstein, F.; Fernandez, C.; Frois, B.; Garabatos, C.; Garzon, J.A.; Gatignon, L.; Gaussiran, T.; Giorgi, M.; Goeler, E. von; Gomez, A.; Gracia, G.; Grosse Perdekamp, M.; Harrach, D. von; Hasegawa, T.; Hayashi, N.; Heusch, C.A.; Horikawa, N.; Hughes, V.W.; Igo, G.; Ishimoto, S.; Iwata, T.; Jong, M. de; Kabuss, E.M.; Kaiser, R.; Karev, A.; Kessler, H.J.; Ketel, T.J.; Kishi, A.; Kisselev, Yu.; Klostermann, L.; Krivokhijine, V.; Kukhtin, V.; Kyynaeraeinen, J.; La; Spin Muon Collaboration (SMC)

    1994-04-11

    A muon beam polarimeter has been built for the SMC experiment at the CERN SPS, for muon energies of 100 to 200 GeV. The beam polarisation is determined from the energy spectrum of positrons from the decay [mu][sup +][yields]e[sup +][nu][sub e] anti [nu][sub [mu

  9. A viscoelastic orthotropic Timoshenko beam subjected to general transverse loading

    Directory of Open Access Journals (Sweden)

    Adámek V.

    2008-12-01

    Full Text Available The investigation of lateral vibrations of a simply supported thin beam is the aim of this work. The analytical solution of the problem is derived based on the approximate Timoshenko beam theory for a general continuous loading acting on the upper beam face over the whole beam width and perpendicular to the beam axis. The material of the beam studied is assumed linear orthotropic viscoelastic. The generalized standard viscoelastic solid is chosen for representing of viscoelastic beam behaviour. Final system of partial integro-differential equations is solved by the standard method of integral transforms and resulting relations describing beam deflection, slope of the beam and corresponding stress and strain components are presented. Moreover, the derivation of final functions of beam deflection and slope of the beam for a specific impulse loading is presented and analytical results are compared with results obtained using numerical simulation in 2D (FEM. This confrontation shows very good agreement between results obtained. Furthermore, it was shown that the measure of agreement depends not only on the beam geometry.

  10. Multipole Field Effects for the Superconducting Parallel-Bar Deflecting/Crabbing Cavities

    Energy Technology Data Exchange (ETDEWEB)

    De Silva, Payagalage Subashini Uddika [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States) and Old Dominion University, Norfolk, VA (United States); Delayen, Jean Roger [Old Dominion University, Norfolk, VA (United States)

    2012-09-01

    The superconducting parallel-bar deflecting/crabbing cavity is currently being considered as one of the design options in rf separation for the Jefferson Lab 12 GeV upgrade and for the crabbing cavity for the proposed LHC luminosity upgrade. Knowledge of multipole field effects is important for accurate beam dynamics study of rf structures. The multipole components can be accurately determined numerically using the electromagnetic surface field data in the rf structure. This paper discusses the detailed analysis of those components for the fundamental deflecting/crabbing mode and higher order modes in the parallel-bar deflecting/crabbing cavity.

  11. Influence of tool deflection on micro channel pattern of 6:4 brass with rectangular tool

    Institute of Scientific and Technical Information of China (English)

    Tae-Jin JE; Kang-Won LEE; Sang-Cheon PARK; Jae-Gu KIM; Doo-Sun CHOI; Kyoung-Taik PARK; Kyung-Hyun WHANG

    2009-01-01

    Machining experiment of micro channel structure with 6:4 brass was carried out by shaping process using a single crystal diamond tool. FEM simulation using solid cantilever beam model was analyzed. In result of experiment, tool deflection is observed as machining characteristics through result of experiments such as surface roughness, cutting force and burr formations. And the influence of tool deflection is experimentally proved.

  12. Electron Cloud Density Measurements in Accelerator Beam-pipe Using Resonant Microwave Excitation

    CERN Document Server

    Sikora, John P

    2013-01-01

    An accelerator beam can generate low energy electrons in the beam-pipe, generally called electron cloud, that can produce instabilities in a positively charged beam. One method of measuring the electron cloud density is by coupling microwaves into and out of the beam-pipe and observing the response of the microwaves to the presence of the electron cloud. This paper describes a technique in which the beam-pipe is resonantly excited with microwaves and the electron cloud density calculated from the change that it produces in the resonant frequency of the beam-pipe. The resonant technique has the advantage that measurements can be localized to sections of beam-pipe that are a meter or less in length, as well as greatly improving the signal to noise ratio.

  13. Prestress Force Identification for Externally Prestressed Concrete Beam Based on Frequency Equation and Measured Frequencies

    Directory of Open Access Journals (Sweden)

    Luning Shi

    2014-01-01

    Full Text Available A prestress force identification method for externally prestressed concrete uniform beam based on the frequency equation and the measured frequencies is developed. For the purpose of the prestress force identification accuracy, we first look for the appropriate method to solve the free vibration equation of externally prestressed concrete beam and then combine the measured frequencies with frequency equation to identify the prestress force. To obtain the exact solution of the free vibration equation of multispan externally prestressed concrete beam, an analytical model of externally prestressed concrete beam is set up based on the Bernoulli-Euler beam theory and the function relation between prestress variation and vibration displacement is built. The multispan externally prestressed concrete beam is taken as the multiple single-span beams which must meet the bending moment and rotation angle boundary conditions, the free vibration equation is solved using sublevel simultaneous method and the semi-analytical solution of the free vibration equation which considered the influence of prestress on section rigidity and beam length is obtained. Taking simply supported concrete beam and two-span concrete beam with external tendons as examples, frequency function curves are obtained with the measured frequencies into it and the prestress force can be identified using the abscissa of the crosspoint of frequency functions. Identification value of the prestress force is in good agreement with the test results. The method can accurately identify prestress force of externally prestressed concrete beam and trace the trend of effective prestress force.

  14. Studies on space charge neutralization and emittance measurement of beam from microwave ion source

    Energy Technology Data Exchange (ETDEWEB)

    Misra, Anuraag; Goswami, A.; Sing Babu, P.; Srivastava, S.; Pandit, V. S., E-mail: pandit@vecc.gov.in, E-mail: vspandit12@gmail.com [Variable Energy Cyclotron Centre, 1-AF, Bidhannagar, Kolkata 700 064 (India)

    2015-11-15

    A 2.45 GHz microwave ion source together with a beam transport system has been developed at VECC to study the problems related with the injection of high current beam into a compact cyclotron. This paper presents the results of beam profile measurement of high current proton beam at different degrees of space charge neutralisation with the introduction of neon gas in the beam line using a fine leak valve. The beam profiles have been measured at different pressures in the beam line by capturing the residual gas fluorescence using a CCD camera. It has been found that with space charge compensation at the present current level (∼5 mA at 75 keV), it is possible to reduce the beam spot size by ∼34%. We have measured the variation of beam profile as a function of the current in the solenoid magnet under the neutralised condition and used these data to estimate the rms emittance of the beam. Simulations performed using equivalent Kapchinsky-Vladimirsky beam envelope equations with space charge neutralization factor are also presented to interpret the experimental results.

  15. Measuring the Polarization of a Rapidly Precessing Deuteron Beam

    CERN Document Server

    Bagdasarian, Z; Chiladze, D; Ciullo, G; Dietrich, J; Dymov, S; Eversmann, D; Fanourakis, G; Gaisser, M; Gebel, R; Gou, B; Guidoboni, G; Hejny, V; Kacharava, A; Kamerdzhiev, V; Lehrach, A; Lenisa, P; Lorentz, B; Magallanes, L; Maier, R; Mchedlishvili, D; Morse, W M; Nass, A; Oellers, D; Pesce, A; Prasuhn, D; Pretz, J; Rathmann, F; Shmakova, V; Semertzidis, Y K; Stephenson, E J; Stockhorst, H; Ströher, H; Talman, R; Engblom, P Thörngren; Valdau, Yu; Weidemann, C; Wüstner, P

    2014-01-01

    This paper describes a time-marking system that enables a measurement of the in-plane (horizontal) polarization of a 0.97-GeV/c deuteron beam circulating in the Cooler Synchrotron (COSY) at the Forschungszentrum J\\"ulich. The clock time of each polarimeter event is used to unfold the 120-kHz spin precession and assign events to bins according to the direction of the horizontal polarization. After accumulation for one or more seconds, the down-up scattering asymmetry can be calculated for each direction and matched to a sinusoidal function whose magnitude is proportional to the horizontal polarization. This requires prior knowledge of the spin tune or polarization precession rate. An initial estimate is refined by re-sorting the events as the spin tune is adjusted across a narrow range and searching for the maximum polarization magnitude. The result is biased toward polarization values that are too large, in part because of statistical fluctuations but also because sinusoidal fits to even random data will prod...

  16. Direct reaction measurements with a 132Sn radioactive ion beam

    CERN Document Server

    Jones, K L; Bardayan, D W; Blackmon, J C; Chae, K Y; Chipps, K A; Cizewski, J A; Erikson, L; Harlin, C; Hatarik, R; Kapler, R; Kozub, R L; Liang, J F; Livesay, R; Ma, Z; Moazen, B H; Nesaraja, C D; Nunes, F M; Pain, S D; Patterson, N P; Shapira, D; Shriner, J F; Smith, M S; Swan, T P; Thomas, J S

    2011-01-01

    The (d,p) neutron transfer and (d,d) elastic scattering reactions were measured in inverse kinematics using a radioactive ion beam of 132Sn at 630 MeV. The elastic scattering data were taken in a region where Rutherford scattering dominated the reaction, and nuclear effects account for less than 8% of the cross section. The magnitude of the nuclear effects was found to be independent of the optical potential used, allowing the transfer data to be normalized in a reliable manner. The neutron-transfer reaction populated a previously unmeasured state at 1363 keV, which is most likely the single-particle 3p1/2 state expected above the N=82 shell closure. The data were analyzed using finite range adiabatic wave calculations and the results compared with the previous analysis using the distorted wave Born approximation. Angular distributions for the ground and first excited states are consistent with the previous tentative spin and parity assignments. Spectroscopic factors extracted from the differential cross sect...

  17. Transverse Beam Halo Measurements at High Intensity Neutrino Source (HINS) using Vibrating Wire Monitor

    Energy Technology Data Exchange (ETDEWEB)

    Chung, M.; Hanna, B.; Scarpine, V.; Shiltsev, V.; Steimel, J.; Artinian, S.; Arutunian, S.

    2015-02-26

    The measurement and control of beam halos will be critical for the applications of future high-intensity hadron linacs. In particular, beam profile monitors require a very high dynamic range when used for the transverse beam halo measurements. In this study, the Vibrating Wire Monitor (VWM) with aperture 60 mm was installed at the High Intensity Neutrino Source (HINS) front-end to measure the transverse beam halo. A vibrating wire is excited at its resonance frequency with the help of a magnetic feedback loop, and the vibrating and sensitive wires are connected through a balanced arm. The sensitive wire is moved into the beam halo region by a stepper motor controlled translational stage. We study the feasibility of the vibrating wire for the transverse beam halo measurements in the low-energy front-end of the proton linac.

  18. Deflection load characteristics of laser-welded orthodontic wires.

    Science.gov (United States)

    Watanabe, Etsuko; Stigall, Garrett; Elshahawy, Waleed; Watanabe, Ikuya

    2012-07-01

    To compare the deflection load characteristics of homogeneous and heterogeneous joints made by laser welding using various types of orthodontic wires. Four kinds of straight orthodontic rectangular wires (0.017 inch × 0.025 inch) were used: stainless-steel (SS), cobalt-chromium-nickel (Co-Cr-Ni), beta-titanium alloy (β-Ti), and nickel-titanium (Ni-Ti). Homogeneous and heterogeneous end-to-end joints (12 mm long each) were made by Nd:YAG laser welding. Two types of welding methods were used: two-point welding and four-point welding. Nonwelded wires were also used as a control. Deflection load (N) was measured by conducting the three-point bending test. The data (n  =  5) were statistically analyzed using analysis of variance/Tukey test (P welded specimens showed lower deflection loads compared to corresponding control wires and exhibited higher deflection loads compared to heterogeneously welded combinations. For homogeneous combinations, Co-Cr-Ni/Co-Cr-Ni showed a significantly (P welded groups. In heterogeneous combinations, SS/Co-Cr-Ni and β-Ti/Ni-Ti showed higher deflection loads than those of the remaining heterogeneously welded combinations (significantly higher for SS/Co-Cr-Ni). Significance (P welding method). However, no significant difference in deflection load was found between four-point and two-point welding in each homogeneous or heterogeneous combination. Heterogeneously laser-welded SS/Co-Cr-Ni and β-Ti/Ni-Ti wires provide a deflection load that is comparable to that of homogeneously welded orthodontic wires.

  19. Linearly polarised photon beams at ELSA and measurement of the beam asymmetry in pi^0-photoproduction off the proton

    CERN Document Server

    Elsner, D; Bartholomy, O; Bayadilov, D E; Beck, R; Beloglasov, Yu A; Castelijns, R; Credé, V; Ehmanns, A; Essig, K; Ewald, R; Fabry, I; Fornet-Ponse, K; Fuchs, M; Funke, C; Gridnev, A B; Gutz, E; Hoeffgen, S; Hoffmeister, P; Horn, I; Jaegle, I; Junkersfeld, J; Kalinowsky, H; Klein, Frank; Klein, Friedrich; Klempt, E; Konrad, M; Kotulla, M; Krusche, B; Löhner, H; Lopatin, I V; Lotz, J; Lugert, S; Menze, D; Mertens, T; Messchendorp, J G; Metag, V; Morales, C; Nanova, M; Novinski, D V; Novotny, R; Ostrick, M; Pant, L M; Van Pee, H; Pfeiffer, M; Sarantsev, A V; Schmidt, C; Schmieden, H; Schoch, B; Shende, S; Suele, A; Sumachev, V V; Szczepanek, T; Thoma, U; Trnka, D; Walther, D; Weinheimer, C; Wendel, C

    2008-01-01

    At the electron accelerator ELSA a linearly polarised tagged photon beam is produced by coherent bremsstrahlung off a diamond crystal. Orientation and energy range of the linear polarisation can be deliberately chosen by accurate positioning of the crystal with a goniometer. The degree of polarisation is determined by the form of the scattered electron spectrum. Good agreement between experiment and expectations on basis of the experimental conditions is obtained. Polarisation degrees of P = 40% are typically achieved at half of the primary electron energy. The determination of P is confirmed by measuring the beam asymmetry, \\Sigma, in pi^0 photoproduction and a comparison of the results to independent measurements using laser backscattering.

  20. Electron beam dispersion measurements in nitrogen using two-dimensional imaging of N2(+) fluorescence

    Science.gov (United States)

    Clapp, L. H.; Twiss, R. G.; Cattolica, R. J.

    Experimental results are presented related to the radial spread of fluorescence excited by 10 and 20 KeV electron beams passing through nonflowing rarefied nitrogen at 293 K. An imaging technique for obtaining species distributions from measured beam-excited fluorescence is described, based on a signal inversion scheme mathematically equivalent to the inversion of the Abel integral equation. From fluorescence image data, measurements of beam radius, integrated signal intensity, and spatially resolved distributions of N2(+) first-negative-band fluorescence-emitting species have been made. Data are compared with earlier measurements and with an heuristic beam spread model.

  1. LHCb: A novel method for an absolute luminosity measurement at LHCb using beam-gas imaging

    CERN Multimedia

    Barschel, C

    2013-01-01

    A novel technique to measure the absolute luminosity at the Large Hadron Collider (LHC) using beam-gas interactions has been successfully used in the LHCb experiment. A gas injection device (SMOG) has been installed in the LHCb experiment to increase the pressure around the interaction point during dedicated fills. The Beam Gas Imaging method (BGI) has now the potential to surpass the accuracy of the commonly used van der Meer scan method (VDM). This poster presents the principles of the Beam Gas Imaging method used to measure the beam overlap integral. Furthermore the gas injection increased the accuracy measurement of the so-called ghost charges and also intensities per bunch.

  2. ElectroOptical measurements of ultrashort 45 MeV electron beam bunch

    CERN Document Server

    Nikas, D; Kowalski, L A; Larsen, R; Lazarus, D M; Ozben, C; Semertzidis, Y K; Tsang, Thomas; Srinivasan-Rao, T

    2001-01-01

    We have made an observation of 45 MeV electron beam bunches using the nondestructive electro-optical (EO) technique. The amplitude of the EO modulation was found to increase linearly with electron beam charge and decrease inversely with the optical beam path distance from the electron beam. The risetime of the signal was bandwidth limited by our detection system to \\~70ps. An EO signal due to ionization caused by the electrons traversing the EO crystal was also observed. The EO technique may be ideal for the measurement of bunch structure with femtosecond resolution of relativistic charged particle beam bunches.

  3. Fluorescence-based knife-edge beam diameter measurement to characterize X-ray beam profiles in reflection geometry

    Science.gov (United States)

    Bassel, Léna; Tauzin, Xavier; Queffelec, Alain; Ferrier, Catherine; Lacanette, Delphine; Chapoulie, Rémy; Bousquet, Bruno

    2016-04-01

    The diameter of an X-ray beam was determined, using the knife-edge technique, widely applied for beam profiling, by taking advantage of the fluorescence emission generated by the X-ray beam. The knife-edge has to be appropriate to the configuration of the device, in our case a double-material target made of plastic and cardboard was scanned in a transversal plane compared to the beam propagation direction. Along the scanning axis, for each position, the intensity of the Kα line of chlorine was recorded. The first derivative of the intensity evolution as a function of the edge position, fitted by a Gaussian function, makes it possible to obtain the beam diameter along the scan direction. We measured a slightly elliptic diameter close to 3 mm. In this note we underline the significance of the knife-edge technique which represents a useful tool, easy to be set up, to control X-ray beam dimensions in portable devices often routinely used by non-specialists.

  4. Measurement of the muon beam direction and muon flux for the T2K neutrino experiment

    CERN Document Server

    Suzuki, K; Ariga, A; Ariga, T; Bay, F; Bronner, C; Ereditato, A; Friend, M; Hartz, M; Hiraki, T; Ichikawa, A K; Ishida, T; Ishii, T; Juget, F; Kikawa, T; Kobayashi, T; Kubo, H; Matsuoka, K; Maruyama, T; Minamino, A; Murakami, A; Nakadaira, T; Nakaya, T; Nakayoshi, K; Oyama, Y; Pistillo, C; Sakashita, K; Sekiguchi, T; Suzuki, S Y; Tada, S; Yamada, Y; Yamamoto, K; Yokoyama, M

    2014-01-01

    The Tokai-to-Kamioka (T2K) neutrino experiment measures neutrino oscillations by using an almost pure muon neutrino beam produced at the J-PARC accelerator facility. The T2K muon monitor was installed to measure the direction and stability of the muon beam which is produced together with the muon neutrino beam. The systematic error in the muon beam direction measurement was estimated, using data and MC simulation, to be 0.28 mrad. During beam operation, the proton beam has been controlled using measurements from the muon monitor and the direction of the neutrino beam has been tuned to within 0.3 mrad with respect to the designed beam-axis. In order to understand the muon beam properties,measurement of the absolute muon yield at the muon monitor was conducted with an emulsion detector. The number of muon tracks was measured to be $(4.06\\pm0.05)\\times10^4$ cm$^{-2}$ normalized with $4\\times10^{11}$ protons on target with 250 kA horn operation. The result is in agreement with the prediction which is corrected ba...

  5. Crack-closing of cement mortar beams using NiTi cold-drawn SMA short fibers

    Science.gov (United States)

    Choi, Eunsoo; Kim, Dong Joo; Chung, Young-Soo; Kim, Hee Sun; Jung, Chungsung

    2015-01-01

    In this study, crack-closing tests of mortar beams reinforced by shape memory alloy (SMA) short fibers were performed. For this purpose, NiTi SMA fibers with a diameter of 0.965 mm and a length of 30 mm were made from SMA wires of 1.0 mm diameter by cold drawing. Four types of SMA fibers were prepared, namely, straight and dog-bone-shaped fiber and the two types of fibers with paper wrapping in the middle of the fibers. The paper provides an unbonded length of 15 mm. For bending tests, six types of mortar beams with the dimensions of 40 mm × 40 mm × 160 mm (B×H×L) were prepared. The SMA fibers were placed at the bottom center of the beams along with an artificial crack of 10 mm depth and 1 mm thickness. This study investigated the influence of SMA fibers on the flexural strength of the beams from the measured force- deflection curves. After cracking, the beams were heated at the bottom by fire to activate the SMA fibers. Then, the beams recovered the deflection, and the cracks were closed. This study evaluated crack-closing capacity using the degree of crack recovery and deflection-recovery factor. The first factor is estimated from the crack-width before and after crack-closing, and the second one is obtained from the downward deflection due to loading and the upward deflection due to the closing force of the SMA fibers.

  6. Installation status of the electron beam profiler for the Fermilab Main Injector

    CERN Document Server

    Thurman-Keup, R; Fitzgerald, J; Lundberg, C; Prieto, P; Roberts, M; Zagel, J; Blokland, W

    2015-01-01

    The planned neutrino program at Fermilab requires large proton beam intensities in excess of 2 MW. Measuring the transverse profiles of these high intensity beams is challenging and often depends on non-invasive techniques. One such technique involves measuring the deflection of a probe beam of electrons with a trajectory perpendicular to the proton beam. A device such as this is already in use at the Spallation Neutron Source at ORNL and the installation of a similar device is underway in the Main Injector at Fermilab. The present installation status of the electron beam profiler for the Main Injector will be discussed together with some simulations and test stand results.

  7. Installation Status of the Electron Beam Profiler for the Fermilab Main Injector

    Energy Technology Data Exchange (ETDEWEB)

    Thurman-Keup, R.; Alvarez, M.; Fitzgerald, J.; Lundberg, C.; Prieto, P.; Roberts, M.; Zagel, J.; Blokland, W.

    2015-11-06

    The planned neutrino program at Fermilab requires large proton beam intensities in excess of 2 MW. Measuring the transverse profiles of these high intensity beams is challenging and often depends on non-invasive techniques. One such technique involves measuring the deflection of a probe beam of electrons with a trajectory perpendicular to the proton beam. A device such as this is already in use at the Spallation Neutron Source at ORNL and the installation of a similar device is underway in the Main Injector at Fermilab. The present installation status of the electron beam profiler for the Main Injector will be discussed together with some simulations and test stand results.

  8. Needle deflection estimation using fusion of electromagnetic trackers.

    Science.gov (United States)

    Sadjadi, H; Hashtrudi-Zaad, K; Fichtinger, G

    2012-01-01

    We present a needle deflection estimation method to compensate for needle bending during insertion into deformable tissue. We combine a kinematic needle deflection estimation model, electromagnetic (EM) trackers, and a Kalman filter (KF). We reduce the impact of error from the needle deflection estimation model by using the fusion of two EM trackers to report the approximate needle tip position in real-time. One reliable EM tracker is installed on the needle base, and estimates the needle tip position using the kinematic needle deflection model. A smaller but much less reliable EM tracker is installed on the needle tip, and estimates the needle tip position through direct noisy measurements. Using a KF, the sensory information from both EM trackers is fused to provide a reliable estimate of the needle tip position with much reduced variance in the estimation error. We then implement this method to compensate for needle deflection during simulated prostate cancer brachytherapy needle insertion. At a typical maximum insertion depth of 15 cm, needle tip mean estimation error was reduced from 2.39 mm to 0.31 mm, which demonstrates the effectiveness of our method, offering a clinically practical solution.

  9. Field distribution analysis in deflecting structures

    Energy Technology Data Exchange (ETDEWEB)

    Paramonov, V.V. [Joint Inst. for Nuclear Research, Moscow (Russian Federation)

    2013-02-15

    Deflecting structures are used now manly for bunch rotation in emittance exchange concepts, bunch diagnostics and to increase the luminosity. The bunch rotation is a transformation of a particles distribution in the six dimensional phase space. Together with the expected transformations, deflecting structures introduce distortions due to particularities - aberrations - in the deflecting field distribution. The distributions of deflecting fields are considered with respect to non linear additions, which provide emittance deteriorations during a transformation. The deflecting field is treated as combination of hybrid waves HE{sub 1} and HM{sub 1}. The criteria for selection and formation of deflecting structures with minimized level of aberrations are formulated and applied to known structures. Results of the study are confirmed by comparison with results of numerical simulations.

  10. UWB Wind Turbine Blade Deflection Sensing for Wind Energy Cost Reduction

    DEFF Research Database (Denmark)

    Zhang, Shuai; Jensen, Tobias Lindstrøm; Franek, Ondrej

    2015-01-01

    A new application of utilizing ultra-wideband (UWB) technology to sense wind turbine blade deflections is introduced in this paper for wind energy cost reduction. The lower UWB band of 3.1–5.3 GHz is applied. On each blade, there will be one UWB blade deflection sensing system, which consists...... is always of sufficient quality for accurate estimations under different deflections. The measured results reveal that the blade tip-root distance and blade deflection can be accurately estimated in the complicated and lossy wireless channels around a wind turbine blade. Some future research topics...

  11. Comparison of beam simulations with measurements for a 1.25-MeV, CW RFQ

    Energy Technology Data Exchange (ETDEWEB)

    Smith, H.V. Jr.; Bolme, G.O.; Sherman, J.D.; Stevens, R.R. Jr.; Young, L.M.; Zaugg, T.J.

    1998-12-31

    The Low-Energy Demonstration Accelerator (LEDA) injector is tested using the Chalk River Injector Test Stand (CRITS) radio-frequency quadrupole (RFQ) as a diagnostic instrument. Fifty-keV, dc proton beams are injected into the 1.25-MeV, CW RFQ and transported to a beamstop. Computer-simulation-code predictions of the expected beam performance are compared with the measured beam currents and beam profiles. Good agreement is obtained between the measurements and the simulations at the 75-mA design RFQ output current.

  12. Measurements of an ion beam diameter extracted into air through a large-bore metal capillary

    Energy Technology Data Exchange (ETDEWEB)

    Hirano, Y.; Umigishi, M. [Graduate School of Humanities and Sciences, Nara Women’s University, Nara 630-8506 (Japan); Ishii, K.; Ogawa, H. [Department of Physics, Nara Women’s University, Nara 630-8506 (Japan)

    2015-07-01

    To extract an ion beam into air, the technique using a single macro-capillary has been paid attention. We have expanded the bore of the metal capillary up to 500 μm∅ inlet diameter to increase the beam intensity and have measured the intensity distributions of the extracted 3 MeV proton beam. Furthermore, we have tilted the capillary angle and measured the intensity distributions of the ion beam. In this article, we will present the experimental results together with the simulation which takes the tilt angles of the capillary into account.

  13. Beam Coupling Impedance Localization Technique Validation and Measurements in the CERN Machines

    CERN Document Server

    Biancacci, N; Argyropoulos, T; Bartosik, H; Calaga, R; Cornelis, K; Gilardoni, S; Métral, E; Mounet, N; Papaphilippou, Y; Persichelli, S; Rumolo, G; Salvant, B; Sterbini, G; Tomàs, R; Wasef, R; Migliorati, M; Palumbo, L

    2013-01-01

    The beam coupling impedance could lead to limitations in beam brightness and quality, and therefore it needs accurate quantification and continuous monitoring in order to detect and mitigate high impedance sources. In the CERN machines, for example, kickers and collimators are expected to be important contributors to the total imaginary part of the transverse impedance. In order to detect the other sources, a beam based measurement was developed: from the variation of betatron phase beating with intensity, it is possible to detect the locations of main impedance sources. In this work we present the application of the method with beam measurements in the CERN PS, SPS and LHC.

  14. ABRUPT DEFLECTED SUPERCRITICAL WATER FLOW IN SLOPED CHANNELS

    Institute of Scientific and Technical Information of China (English)

    LIU Ya-kun; NI Han-gen

    2008-01-01

    The effect of the bottom slope on abrupt deflected supercritical water flow was experimentally and theoretically studied. Model tests were conducted in a flume of 1.2 m wide and 2.6 m long with sloped bottom at an angle 35.54o, its length of deflector was 0.2 m and the deflection angles were 15o and 30o. An approximate method for calculatjng the shock wave angle and depth ratio of the abrupt deflected supercritical water flow was suggested, and a correction coefficient for the hydrodynamic pressure was introduced to generalize the momentum equation in the direction perpendicular to the shock front. It must be noticed that in the sloped channel the shock wave angle and the depth ratio are no longer constant as those in the horizontal channels, but slowly change along the shock front. The calculated results are in good agreement with measured data.

  15. Multiplexed Force and Deflection Sensing Shell Membranes for Robotic Manipulators

    Science.gov (United States)

    Park, Yong-Lae; Black, Richard; Moslehi, Behzad; Cutkosky, Mark; Chau, Kelvin

    2012-01-01

    Force sensing is an essential requirement for dexterous robot manipulation, e.g., for extravehicular robots making vehicle repairs. Although strain gauges have been widely used, a new sensing approach is desirable for applications that require greater robustness, design flexibility including a high degree of multiplexibility, and immunity to electromagnetic noise. This invention is a force and deflection sensor a flexible shell formed with an elastomer having passageways formed by apertures in the shell, with an optical fiber having one or more Bragg gratings positioned in the passageways for the measurement of force and deflection.

  16. SU-E-T-146: Beam Energy Spread Estimate Based On Bragg Peak Measurement

    Energy Technology Data Exchange (ETDEWEB)

    Anferov, V; Derenchuk, V; Moore, R [ProNova Solutions, Knoxville, TN (United States); Schreuder, A [Provision Healthcare Partners, Knoxville, TN (United States)

    2015-06-15

    Purpose: ProNova is installing and commissioning a two room proton therapy system in Knoxville, TN. Beam energy out of the 230MeV cyclotron was measured on Jan 24, 2015. Cyclotron beam was delivered into a Zebra multi layered IC detector calibrated in terms of penetration range in water. The analysis of the measured Bragg peak determines penetration range in water which can be subsequently converted into proton beam energy. We extended this analysis to obtain an estimate of the beam energy spread out of the cyclotron. Methods: Using Monte Carlo simulations we established the correlation between Bragg peak shape parameters (width at 50% and 80% dose levels, distal falloff) and penetration range for a monoenergetic proton beam. For large uniform field impinging on a small area detector, we observed linear dependence of each Bragg peak parameter on beam penetration range as shown in Figure A. Then we studied how this correlation changes when the shape of Bragg peak is distorted by the beam focusing conditions. As shown in Figure B, small field size or diverging beam cause Bragg peak deformation predominantly in the proximal region. The distal shape of the renormalized Bragg peaks stays nearly constant. This excludes usage of Bragg peak width parameters for energy spread estimates. Results: The measured Bragg peaks had an average distal falloff of 4.86mm, which corresponds to an effective range of 35.5cm for a monoenergetic beam. The 32.7cm measured penetration range is 2.8cm less. Passage of a 230MeV proton beam through a 2.8cm thick slab of water results in a ±0.56MeV energy spread. As a final check, we confirmed agreement between shapes of the measured Bragg peak and one generated by Monte-Carlo code for proton beam with 0.56 MeV energy spread. Conclusion: Proton beam energy spread can be estimated using Bragg peak analysis.

  17. Measurements of effective total macroscopic cross sections and effective energy of continuum beam

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Hisao [Rikkyo Univ., Yokosuka, Kanagawa (Japan). Inst. for Atomic Energy

    1998-03-01

    Two practically useful quantities are introduced in this study to characterize a continuum neutron beam and to describe transmission phenomena of the beam in field of quantitative neutron radiography: an effective energy instead of a peak energy or a mean energy of the spectrum and an effective total macroscopic (ETM) cross section instead of a total macroscopic (TM) cross section defined at the monochromatic energy. The effective energy was evaluated by means of energy dependence of ETM cross section. To realize the method a beam quality indicator (BQI) has been proposed recently. Several effective energies were measured for non-filtered, filtered neutron beams, and outputs of neutron guide tubes in world by the BQI. A thermal neutron beam and three beams modulated by Pb filters with different thicknesses are studied to measure ETM cross sections for various materials and summarized in a table. Validity of the effective energy determined by the BQI is discussed relating with ETM cross sections of materials. (author)

  18. Comparison between measured and simulated beam loss patterns in the CERN SPS

    CERN Document Server

    Redaelli, S; Assmann, R W; Robert-Démolaize, G

    2006-01-01

    A prototype of an LHC collimator has been tested with proton beams at the CERN SPS. The interaction of the circulating proton beam with the carbon collimator jaws generated secondary proton beams that were lost in the downstream SPS aperture. The measured beam loss patterns are compared with the results of dedicated loss simulations. The simulation package includes (1) a 6D particle tracking through the SPS lattice; (2) the scattering interaction of protons with the collimator jaw material; (3) the timedependent displacement of the collimator jaws with respect to the beam orbit; (4) a detailed aperture model of the full SPS ring. It is shown that the simulation tools can reliably predict the measured location of losses. This provides an important assessment of the simulation tools in view of the beam loss studies for the Large Hadron Collider (LHC).

  19. Measuring coalignment of retroreflectors with large lateral incoming-outgoing beam offset

    Energy Technology Data Exchange (ETDEWEB)

    Schütze, Daniel, E-mail: Daniel.Schuetze@aei.mpg.de; Sheard, Benjamin S.; Heinzel, Gerhard; Danzmann, Karsten [Max Planck Institute for Gravitational Physics (Albert Einstein Institute) and Institute for Gravitational Physics, Leibniz Universität Hannover, Callinstr. 38, 30167 Hanover (Germany); Farrant, David [Commonwealth Scientific and Industrial Research Organisation, Bradfield Road, Lindfield, NSW 2070 (Australia); Shaddock, Daniel A. [Centre for Gravitational Physics, Australian National University, Acton, ACT 0200 (Australia)

    2014-03-15

    A method based on phase-shifting Fizeau interferometry is presented with which retroreflectors with large incoming-outgoing beam separations can be tested. The method relies on a flat Reference Bar that is used to align two auxiliary mirrors parallel to each other to extend the aperture of the interferometer. The method is applied to measure the beam coalignment of a prototype Triple Mirror Assembly of the GRACE Follow-On Laser Ranging Interferometer, a future satellite-to-satellite tracking device for Earth gravimetry. The Triple Mirror Assembly features a lateral beam offset of incoming and outgoing beam of 600 mm, whereas the acceptance angle for the incoming beam is only about ±2 mrad. With the developed method, the beam coalignment of the prototype Triple Mirror Assembly was measured to be 9 μrad with a repeatability of below 1 μrad.

  20. Compensations of beamlet deflections for 1 MeV accelerator of ITER NBI

    Science.gov (United States)

    Kashiwagi, Mieko; Taniguchi, Masaki; Umeda, Naotaka; Dairaku, Masayuki; Tobari, Hiroyuki; Yamanaka, Haruhiko; Watanabe, Kazuhiro; Inoue, Takashi; de Esch, H. P. L.; Grisham, Larry R.; Boilson, Deirdre; Hemsworth, Ronald S.; Tanaka, Masanobu

    2013-02-01

    Compensation methods of beamlet deflections have been studied in a three dimensional (3D) beam analysis using OPERA-3d code for 1 MeV accelerator of the ITER neutral beam injector (NBI). The beamlet deflection is caused by i) magnetic field generated by permanent magnets embedded in the extraction grid (EXG) for electron suppression and ii) space charge repulsion between the beamlets and beam groups. Moreover, the beamlet deflection is caused due to electric field distortion formed by a grid support structure. In order to compensate the beamlet deflections due to i) and ii), an aperture offset of 0.6 mm was applied in the electron suppression grid (ESG) and a metal bar with 3 mm in thickness, so-called a kerb, was attached around the aperture area at the back side of the ESG, respectively. Detailed configuration of the compensation methods was also considered so as to suppress the beam spread due to the electric field distortion and to lower electric field concentrations at the edge of the kerb. For the beamlets near the grid support structure, the beamlet deflection due to the space charge repulsion could be negated due to the electric field distortion formed by the grid support structure.

  1. Measurements of Variable-Shaped Electron Beams with Solid-State Detector and Scattering Aperture

    Science.gov (United States)

    Sakakibara, Makoto; Ohta, Hiroya; Kanosue, Tadashi; Sohda, Yasunari; Ban, Naoma

    2007-09-01

    A highly accurate method for measuring beam properties in a variable-shaped electron beam (VSB) system has been developed. This method is based on a knife-edge method with a solid-state detector (SSD) and scattering apertures. In VSB system, it is necessary to measure both beam profile and beam position for a long time. To meet this requirement, many aperture marks on a silicon membrane were prepared in a measurement unit. Using this unit, the accuracy and stability of beam-size and beam position measurements were evaluated in VBS system (HL-7000D, Hitachi-HITEC). As a result, the repeatability error for beam size was obtained to be smaller than 2 nm (3σ) and the repeatability error for beam position was obtained to be 0.82 nm (3σ). Moreover, a multitude of repeat experiments showed that this measurement unit can be used for more than ten years. Consequently, it was confirmed that this measurement method is useful for the high accuracy of a VSB system.

  2. Deflection Control in Rigid Pavements

    Science.gov (United States)

    Varunkrishna, Nulu; Jayasankar, R.

    2017-07-01

    The need for modern transportation systems together with the high demand for perpetual pavements under the drastically increasing applied loads has led to a great deal of research on concrete as a pavement material worldwide. This research indeed instigated many modifications in concrete aiming for improving the concrete properties. Pavement Quality Concrete requires higher flexural strength and fewer deflections in hardened state. Fiber reinforcement and latex modification are two reliable approaches serving the required purposes. The concrete made with these two modifications is called Polymer-modified Fiber-reinforced concrete. The present study deals with the usage of polypropylene as fiber and SBR (Styrene Butadiene Rubber) Latex as polymer. M30 grade concrete was modified by replacing cement with two different percentages of fiber (0.5%, 1.0% of weight of cement) and with three different percentages of SBR latex (10%, 15% & 20% of weight of cement).

  3. Measurement of the Beam Size and Emittance for the CRC Cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sae Hoon; Kim, Yu Seok [Dongguk University, Gyeongju (Korea, Republic of)

    2012-05-15

    The purpose of the present study was to confirm beam property for regional Cyclotron Research Center (CRC) installed at Chosun University Hospital. The regional CRC has been developed to produce radioisotope for positron emission tomography (PET). The original radioisotope production cyclotron had a large beam size, which need to be reduced by collimator. In order to construct the proton-induced X-ray emission and proton-induced gamma-ray emission (PIXE-PIGE) beam line, ion beam will be transported to PIXE-PIGE chamber that we have identified the beam size decreased by collimator and beam emittance. There are several methods to measure the emittace, such as the slit and collector method, the pepper-pot method, and the quad scan method. These methods use a slit and monitor to measure the beam profiles, which depend on the field gradient of the quadrupole magnet. In this study, we did not use magnet and monitor. The emittance calculation based on simulated data by previously proven program is approached to consider various methods. Beam emittance was calculated in two methods. The two methods were classical method and ion beam position with divergence method. We found that the beam sizes of x, y-direction are reduced very well

  4. Generating and measuring non-diffracting vector Bessel beams

    CSIR Research Space (South Africa)

    Dudley, Angela L

    2014-03-01

    Full Text Available ,” Adv. Opt. Photon 1, 1 (2009). [2] Brown, T. G. and Zhan, Q., “Introduction: Unconventional Polarization States of Light Focus Issue,” Opt. Express 18, 10775 (2010). [3] Hasman, E., Biener, G., Niv, A. and Kleiner, V., [Space-variant polarization... manipulation], Elsevier, 215-289 (2005). [4] Brown, T. G., [Unconventional polarization states: beam propagation, focusing and imaging], Elsevier, 8-129 (2011). [5] Beckley, A. M., Brown, T. G., and Alonso, M. A., “Full Poincare beams,”Opt. Express 18...

  5. A new measurement method of electrode gains for orthogonal symmetric type beam position monitor

    CERN Document Server

    Zou, J Y; Yang, Y L; Sun, B G; Zhou, Z R; Luo, Q; Lu, P; Xu, H L

    2014-01-01

    The new beam position monitor (BPM) system of the injector at the upgrade project of Hefei Light Source (HLS II) has 19 stripline beam position monitors. Most consist of four orthogonal symmetric stripline electrodes. The differences in electronic gain and mismachining tolerance can cause the change of the beam response of the BPM electrodes. This variation will couple the two measured horizontal positions in order to bring the measuring error. To alleviate this effect, a new technique to measure the relative response of the four electrodes has been developed. It is irrelevant to the beam charge and the related coefficient can be theoretical calculated. The effect of electrodes coupling on this technique is analyzed. The calibration data is used to fit the gain for all 19 injector beam position monitors. The results show the standard deviation of the distribution of measured gains is about 5%.

  6. Analytic modeling, simulation and interpretation of broadband beam coupling impedance bench measurements

    Energy Technology Data Exchange (ETDEWEB)

    Niedermayer, U., E-mail: niedermayer@temf.tu-darmstadt.de [Institut für Theorie Elektromagnetischer Felder (TEMF), Technische Universität Darmstadt, Schloßgartenstraße 8, 64289 Darmstadt (Germany); Eidam, L. [Institut für Theorie Elektromagnetischer Felder (TEMF), Technische Universität Darmstadt, Schloßgartenstraße 8, 64289 Darmstadt (Germany); Boine-Frankenheim, O. [Institut für Theorie Elektromagnetischer Felder (TEMF), Technische Universität Darmstadt, Schloßgartenstraße 8, 64289 Darmstadt (Germany); GSI Helmholzzentrum für Schwerionenforschung, Planckstraße 1, 64291 Darmstadt (Germany)

    2015-03-11

    First, a generalized theoretical approach towards beam coupling impedances and stretched-wire measurements is introduced. Applied to a circular symmetric setup, this approach allows to compare beam and wire impedances. The conversion formulas for TEM scattering parameters from measurements to impedances are thoroughly analyzed and compared to the analytical beam impedance solution. A proof of validity for the distributed impedance formula is given. The interaction of the beam or the TEM wave with dispersive material such as ferrite is discussed. The dependence of the obtained beam impedance on the relativistic velocity β is investigated and found as material property dependent. Second, numerical simulations of wakefields and scattering parameters are compared. The applicability of scattering parameter conversion formulas for finite device length is investigated. Laboratory measurement results for a circularly symmetric test setup, i.e. a ferrite ring, are shown and compared to analytic and numeric models. The optimization of the measurement process and error reduction strategies are discussed.

  7. Transverse Beam Emittance Measurements of a 16 MeV Linac at the Idaho Accelerator Center

    Energy Technology Data Exchange (ETDEWEB)

    S. Setiniyaz, T.A. Forest, K. Chouffani, Y. Kim, A. Freyberger

    2012-07-01

    A beam emittance measurement of the 16 MeV S-band High Repetition Rate Linac (HRRL) was performed at Idaho State University's Idaho Accelerator Center (IAC). The HRRL linac structure was upgraded beyond the capabilities of a typical medical linac so it can achieve a repetition rate of 1 kHz. Measurements of the HRRL transverse beam emittance are underway that will be used to optimize the production of positrons using HRRL's intense electron beam on a tungsten converter. In this paper, we describe a beam imaging system using on an OTR screen and a digital CCD camera, a MATLAB tool to extract beamsize and emittance, detailed measurement procedures, and the measured transverse emittances for an arbitrary beam energy of 15 MeV.

  8. Multipass beam position, profile, and polarization measurements using intense photon target

    Energy Technology Data Exchange (ETDEWEB)

    Karabekov, I.P.; Neil, G.R. [Continuous Electron Beam Accelerator Facility, Newport News, VA (United States); Karabekian, S.; Musakhanian, V. [Yerevan Physics Inst., Erevan (Armenia)

    1994-05-01

    The Compton scattering of a circularly polarized laser beam condensed by an optical resonator can be used for multipass measurement of beam profile, position, and polarization in CEBAF`s 250-m-long linac straight sections. The position and profile of the beam will be measured with an accuracy of {approximately}10 {mu}m in about 200 seconds and beam polarization with 10% accuracy in 100 seconds when the lowest beam energy is 500 MeV and the beam current is 100 {mu}A. For higher energies the times for measurement are much less. The photon target is within an optical resonator having a quality factor of 50. The Nd:Yag 5 W CW laser photon beam at wavelength {lambda} = 0.532 nm will have a waist {omega}{sub o} {approximately}30 {mu}m and a Rayleigh range of about 10 mm. Scanning the electron beams in the linac sections by this photon beam at a crossing angle of 0.1 rad will send to a proportional detector installed after the spreader magnet scattered photons with energies sharply correlated with the energy of the electrons.

  9. Pulse-mode measurement of electron beam halo using diamond-based detector

    Science.gov (United States)

    Aoyagi, Hideki; Asano, Yoshihiro; Itoga, Toshiro; Nariyama, Nobuteru; Bizen, Teruhiko; Tanaka, Takashi; Kitamura, Hideo

    2012-02-01

    Using a diamond-based detector, the electron beam halo in a high-energy accelerator can be measured with a lower detection limit than that using other instruments, such as a core monitor, a dose meter, or an optical fiber. We have successfully measured an electron beam halo using diamond-based detectors operating in the ionization mode, which were installed in the beam duct to measure the intensity of the beam halo directly. Pulse-by-pulse measurements were adopted to suppress the background noise efficiently. Feasibility tests on the diamond-based detector and beam halo monitor were performed in the beam dump area of the 8 GeV SPring-8 synchrotron booster and at the 250 MeV SPring-8 Compact SASE Source test accelerator for the SPring-8 Angstrom Compact free electron LAser (SACLA), respectively. We achieved a lower detection limit of 2×103electrons/pulse for single-shot measurement, which corresponds to a ratio of about 10-6 relative to the typical charge of the beam core of 0.3 pC. We also confirmed the feasibility of the electron beam halo monitor for use as an interlock sensor to protect undulator permanent magnets used in SACLA from radiation damage.

  10. Pulse-mode measurement of electron beam halo using diamond-based detector

    Directory of Open Access Journals (Sweden)

    Hideki Aoyagi

    2012-02-01

    Full Text Available Using a diamond-based detector, the electron beam halo in a high-energy accelerator can be measured with a lower detection limit than that using other instruments, such as a core monitor, a dose meter, or an optical fiber. We have successfully measured an electron beam halo using diamond-based detectors operating in the ionization mode, which were installed in the beam duct to measure the intensity of the beam halo directly. Pulse-by-pulse measurements were adopted to suppress the background noise efficiently. Feasibility tests on the diamond-based detector and beam halo monitor were performed in the beam dump area of the 8 GeV SPring-8 synchrotron booster and at the 250 MeV SPring-8 Compact SASE Source test accelerator for the SPring-8 Angstrom Compact free electron LAser (SACLA, respectively. We achieved a lower detection limit of 2×10^{3}  electrons/pulse for single-shot measurement, which corresponds to a ratio of about 10^{-6} relative to the typical charge of the beam core of 0.3 pC. We also confirmed the feasibility of the electron beam halo monitor for use as an interlock sensor to protect undulator permanent magnets used in SACLA from radiation damage.

  11. Improving Multi-Beam Echo Sounder Depth Measurements

    NARCIS (Netherlands)

    Snellen, M.; Ameele, J.J.P. van den; Biersteker, R.; Simons, D.G.

    2006-01-01

    An important research question is how to adequately correct multi-beam echo sounder (MBES) bathymetric data for refraction effects. This is especially relevant for survey areas, like the Maasgeul area off the Dutch coast, where the water column properties and thus the prevailing sound speed profile

  12. Measurement of Beam Loss at the Australian Synchrotron

    CERN Document Server

    Holzer, EB; Kastriotou, M; Boland, MJ; Jackson, PD; Rasool, RP; Schmidt, J; Welsch, CP

    2014-01-01

    The unprecedented requirements that new machines are setting on their diagnostic systems is leading to the development of new generation of devices with large dynamic range, sensitivity and time resolution. Beam loss detection is particularly challenging due to the large extension of new facilities that need to be covered with localized detector. Candidates to mitigate this problem consist of systems in which the sensitive part of the radiation detectors can be extended over long distance of beam lines. In this document we study the feasibility of a BLM system based on optical fiber as an active detector for an electron storage ring. The Australian Synchrotron (AS) comprises a 216m ring that stores electrons up to 3GeV. The Accelerator has recently claimed the world record ultra low transverse emittance (below pm rad) and its surroundings are rich in synchrotron radiation. Therefore, the AS provides beam conditions very similar to those expected in the CLIC/ILC damping rings. A qualitative benchmark of beam l...

  13. Short-term and long-term deflection of reinforced hollow core ...

    African Journals Online (AJOL)

    Short-term and long-term deflection of reinforced hollow core concrete slab systems. ... AFRICAN JOURNALS ONLINE (AJOL) · Journals · Advanced Search ... For the prediction of the long-term deflection, a measured ratio of long-term ...

  14. Maximum entropy algorithm and its implementation for the neutral beam profile measurement

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seung Wook; Cho, Gyu Seong [Korea Advanced Institute of Science and Technology, Taejon (Korea, Republic of); Cho, Yong Sub [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1997-12-31

    A tomography algorithm to maximize the entropy of image using Lagrangian multiplier technique and conjugate gradient method has been designed for the measurement of 2D spatial distribution of intense neutral beams of KSTAR NBI (Korea Superconducting Tokamak Advanced Research Neutral Beam Injector), which is now being designed. A possible detection system was assumed and a numerical simulation has been implemented to test the reconstruction quality of given beam profiles. This algorithm has the good applicability for sparse projection data and thus, can be used for the neutral beam tomography. 8 refs., 3 figs. (Author)

  15. Muon $g-2$ measurements and non-commutative geometry of quantum beams

    Indian Academy of Sciences (India)

    Y Srivastava; A Widom

    2004-03-01

    We discuss a completely quantum mechanical treatment of the measurement of the anomalous magnetic moment of the muon. A beam of muons move in a strong uniform magnetic field and a weak focusing electrostatic field. Errors in the classical beam analysis are exposed. In the Dirac quantum beam analysis, an important role is played by non-commutative muon beam coordinates leading to a discrepancy between the classical and quantum theories. We obtain a quantum limit to the accuracy achievable in BNL type experiments. Some implications of the quantum corrected data analysis for supersymmetry are briefly mentioned.

  16. The use of radiochromic films to measure and analyze the beam profile of charged particle accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Avila-Rodriguez, M.A. [Edmonton PET Centre, Cross Cancer Institute, 11560 University Ave, Edmonton, AB T6G 1Z2 (Canada); Unidad PET/CT-Ciclotron, Facultad de Medicina, Universidad Nacional Autonoma de Mexico (Mexico)], E-mail: avilarod@uwalumni.com; Wilson, J.S.; McQuarrie, S.A. [Edmonton PET Centre, Cross Cancer Institute, 11560 University Ave, Edmonton, AB T6G 1Z2 (Canada)

    2009-11-15

    The use of radiochromic films as a simple and inexpensive tool to accurately measure and analyze the beam profile of charged particle accelerators is described. In this study, metallic foils of different materials and thicknesses were irradiated with 17.8 MeV protons and autoradiographic images of the beam strike were acquired by exposing pieces of RCF in direct contact with the irradiated foils. The films were digitalized using a conventional scanner and images were analyzed using DoseLab. Beam intensity distributions, isodose curves and linear beam profiles of the digitalized images were acquired.

  17. The use of radiochromic films to measure and analyze the beam profile of charged particle accelerators.

    Science.gov (United States)

    Avila-Rodriguez, M A; Wilson, J S; McQuarrie, S A

    2009-11-01

    The use of radiochromic films as a simple and inexpensive tool to accurately measure and analyze the beam profile of charged particle accelerators is described. In this study, metallic foils of different materials and thicknesses were irradiated with 17.8MeV protons and autoradiographic images of the beam strike were acquired by exposing pieces of RCF in direct contact with the irradiated foils. The films were digitalized using a conventional scanner and images were analyzed using DoseLab. Beam intensity distributions, isodose curves and linear beam profiles of the digitalized images were acquired.

  18. Impact of beam ions on α-particle measurements by collective Thomson scattering in ITER

    DEFF Research Database (Denmark)

    Egedal, J.; Bindslev, H.; Budny, R.V.

    2005-01-01

    Collective Thomson scattering (CTS) has been proposed as a viable diagnostic for characterizing fusion born a-distributions in ITER. However, the velocities of the planned 1 MeV deuterium heating beam ions in 1TER are similar to that of fusion born a-particles and may therefore mask...... the measurements of the fusion products. We apply a new technique for calculating the orbit averaged source, (S), of beam ions for various ITER scenarios. With the known (S) Fokker-Planck modelling is applied to characterize the beam ions during the slowing down process. Theoretical CTS signals for both beam ions...

  19. Modelling and calibration of the laser beam-scanning triangulation measurement system

    NARCIS (Netherlands)

    Wang, Guoyu; Zheng, Bing; Li, Xin; Houkes, Z.; Regtien, P.P.L.

    2002-01-01

    We present an approach of modelling and calibration of an active laser beam-scanning triangulation measurement system. The system works with the pattern of two-dimensional beam-scanning illumination and one-dimensional slit-scanning detection with a photo-multiplier tube instead of a CCD camera. By

  20. Measurement of M²-Curve for Asymmetric Beams by Self-Referencing Interferometer Wavefront Sensor.

    Science.gov (United States)

    Du, Yongzhao

    2016-11-29

    For asymmetric laser beams, the values of beam quality factor M x 2 and M y 2 are inconsistent if one selects a different coordinate system or measures beam quality with different experimental conditionals, even when analyzing the same beam. To overcome this non-uniqueness, a new beam quality characterization method named as M²-curve is developed. The M²-curve not only contains the beam quality factor M x 2 and M y 2 in the x-direction and y-direction, respectively; but also introduces a curve of M x α 2 versus rotation angle α of coordinate axis. Moreover, we also present a real-time measurement method to demonstrate beam propagation factor M²-curve with a modified self-referencing Mach-Zehnder interferometer based-wavefront sensor (henceforth SRI-WFS). The feasibility of the proposed method is demonstrated with the theoretical analysis and experiment in multimode beams. The experimental results showed that the proposed measurement method is simple, fast, and a single-shot measurement procedure without movable parts.

  1. Modelling and calibration of the laser beam-scanning triangulation measurement system

    NARCIS (Netherlands)

    Wang, G.Y.; Zheng, Bing; Li, Xin; Houkes, Z.; Regtien, Paulus P.L.

    2002-01-01

    We present an approach of modelling and calibration of an active laser beam-scanning triangulation measurement system. The system works with the pattern of two-dimensional beam-scanning illumination and one-dimensional slit-scanning detection with a photo-multiplier tube instead of a CCD camera. By

  2. Development of atomic-beam resonance method to measure the nuclear moments of unstable nuclei

    Energy Technology Data Exchange (ETDEWEB)

    Sugimoto, T., E-mail: sugimoto@ribf.riken.jp [SPring-8 (Japan); Asahi, K. [Tokyo Institute of Technology, Department of Physics (Japan); Kawamura, H.; Murata, J. [Rikkyo University, Department of Physics (Japan); Nagae, D.; Shimada, K. [Tokyo Institute of Technology, Department of Physics (Japan); Ueno, H.; Yoshimi, A. [RIKEN Nishina Center (Japan)

    2008-01-15

    We have been working on the development of a new technique of atomic-beam resonance method to measure the nuclear moments of unstable nuclei. In the present study, an ion-guiding system to be used as an atomic-beam source have been developed.

  3. Measurement of the beam asymmetry in eta photoproduction off the proton

    NARCIS (Netherlands)

    Elsner, D.; Anisovich, A. V.; Anton, G.; Bacelar, J. C. S.; Bantes, B.; Bartholomy, O.; Bayadilov, D. E.; Beck, R.; Beloglazov, Y. A.; Bogendoerfer, R.; Castelijns, R.; Crede, V.; Dutz, H.; Ehmanns, A.; Essig, K.; Ewald, R.; Fabry, I.; Flemming, H.; Fornet-Ponse, K.; Fuchs, M.; Funke, C.; Gothe, R.; Gregor, R.; Gridnev, A. B.; Gutz, E.; Hoeffgen, S.; Hoffmeister, P.; Horn, I.; Hoessl, J.; Jaegle, I.; Junkersfeld, J.; Kammer, H. Kalinowsky S.; Klein, V. Kleber Frank; Klein, Friedrich; Klempt, E.; Koch, H.; Konrad, M.; Kopf, B.; Kotulla, M.; Krusche, B.; Lang, M.; Langheinrich, J.; Löhner, H.; Lopatin, I. V.; Lotz, J.; Ay, S. Lugert H. Matth; Menze, D.; Mertens, T.; Messchendorp, J. G.; Metag, V.; Morales, C.; Nanova, M.; Nikonov, V. A.; Novinski, D. V.; Novotny, R.; Ostrick, M.; Pant, L. M.; Van Pee, H.; Pfeiffer, M.; Radkov, A. K.; Sarantsev, A. V.; Schadmand, S.; Schmidt, C.; Schmieden, H.; Schoch, B.; Shende, S.; Ule, A. S.; Sumachev, V. V.; Szczepanek, T.; Thoma, U.; Trnka, D.; Walther, D.; Weinheimer, C.; Wendel, C.; Suft, G.; Suele, A.; Sumachev, V. V.; Szczepanek, T.; Thoma, U.; Trnka, D.; Walther, D.; Weinheimer, C.; Wendel, C.

    2007-01-01

    The beam asymmetry, Sigma, was measured at ELSA in the reaction gamma p -> eta p using linearly polarised tagged photon beams, produced by coherent bremsstrahlung o ff a diamond. The crystal was oriented to provide polarised photons in the energy range E-gamma = 800 to 1400MeV with the maximum polar

  4. Measurement of M2-Curve for Asymmetric Beams by Self-Referencing Interferometer Wavefront Sensor

    Directory of Open Access Journals (Sweden)

    Yongzhao Du

    2016-11-01

    Full Text Available For asymmetric laser beams, the values of beam quality factor M x 2 and M y 2 are inconsistent if one selects a different coordinate system or measures beam quality with different experimental conditionals, even when analyzing the same beam. To overcome this non-uniqueness, a new beam quality characterization method named as M2-curve is developed. The M2-curve not only contains the beam quality factor M x 2 and M y 2 in the x-direction and y-direction, respectively; but also introduces a curve of M x α 2 versus rotation angle α of coordinate axis. Moreover, we also present a real-time measurement method to demonstrate beam propagation factor M2-curve with a modified self-referencing Mach-Zehnder interferometer based-wavefront sensor (henceforth SRI-WFS. The feasibility of the proposed method is demonstrated with the theoretical analysis and experiment in multimode beams. The experimental results showed that the proposed measurement method is simple, fast, and a single-shot measurement procedure without movable parts.

  5. Energy Dissipation Capacity of Reinforced Concrete Beams Strengthened with CFRP Strips

    Science.gov (United States)

    Hong, Sungnam; Park, Sun-Kyu

    2016-05-01

    Cyclic loading tests were performed to investigate the energy dissipation capacities of reinforced concrete (RC) beams strengthened with carbon-fiber-reinforced polymer (CFRP) strips. Four RC beams were manufactured and three-point loaded. Responses of the strengthened beams to the cyclic loadings were measured, including deflections at the center of their span and strains of the CFRP strips and reinforcing steel rebars. Based on test results, the energy dissipation capacity of the strengthened beams were evaluated in comparison with that of an unstrengthened control beam.

  6. Modeled and Measured Dynamics of a Composite Beam with Periodically Varying Foam Core

    Science.gov (United States)

    Cabell, Randolph H.; Cano, Roberto J.; Schiller, Noah H.; Roberts Gary D.

    2012-01-01

    The dynamics of a sandwich beam with carbon fiber composite facesheets and foam core with periodic variations in material properties are studied. The purpose of the study is to compare finite element predictions with experimental measurements on fabricated beam specimens. For the study, three beams were fabricated: one with a compliant foam core, a second with a stiffer core, and a third with the two cores alternating down the length of the beam to create a periodic variation in properties. This periodic variation produces a bandgap in the frequency domain where vibrational energy does not readily propagate down the length of the beam. Mode shapes and natural frequencies are compared, as well as frequency responses from point force input to velocity response at the opposite end of the beam.

  7. Interferometric measurement of the beam size in the compact storage ring

    CERN Document Server

    Yamamoto, Y; Mitsuhashi, T; Amano, D; Iwasaki, H

    2001-01-01

    The beam size in the compact superconducting storage ring AURORA at Ritsumeikan University was measured using the SR-interferometer. The radiation beam from the bending magnet was passed through the double-slit and an interferogram formed in the visible spectral region was recorded using a CCD camera. The spatial coherence of the beam was derived from the analysis of the intensity profile and its dependence on the spatial frequency has yielded the beam size of 10.5 mu m in the vertical direction. It is unexpectedly small, indicating a high accuracy in the design of magnetic field in the magnet. The beam size could be varied by applying an rf kick electric field and the dependence of the beam lifetime on the size has shown that it is primarily governed by the Tauschek effect.

  8. Residual stress in Ta2O5-SiO2 composite thin-film rugate filters prepared by radio frequency ion-beam sputtering.

    Science.gov (United States)

    Tang, Chien-Jen; Jaing, Cheng-Chung; Lee, Kuan-Shiang; Lee, Cheng-Chung

    2008-05-01

    Ta-Si oxide composite thin-film rugate filters were prepared by radio frequency ion-beam sputtering and their residual stress and substrate deflections were measured. The residual stress and substrate deflection of these composite film rugate filters were less than that of notch filters made from a series of discrete quarter-wave layers with alternate high and low indices because of the smooth modulation of composition and no interface structure of the rugate filter.

  9. A 128-channel picoammeter system and its application on charged particle beam current distribution measurements

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Deyang, E-mail: d.yu@impcas.ac.cn; Liu, Junliang; Xue, Yingli; Zhang, Mingwu; Cai, Xiaohong; Hu, Jianjun; Dong, Jinmei [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); Li, Xin [School of Nuclear Science and Technology, Lanzhou University, Lanzhou 730000 (China)

    2015-11-15

    A 128-channel picoammeter system is constructed based on instrumentation amplifiers. Taking advantage of a high electric potential and narrow bandwidth in DC energetic charged beam measurements, a current resolution better than 5 fA can be achieved. Two sets of 128-channel strip electrodes are implemented on printed circuit boards and are employed for ion and electron beam current distribution measurements. Tests with 60 keV O{sup 3+} ions and 2 keV electrons show that it can provide exact boundaries when a positive charged particle beam current distribution is measured.

  10. Four-dimensional transverse beam matrix measurement using the multiple-quadrupole scan technique

    Directory of Open Access Journals (Sweden)

    Eduard Prat

    2014-05-01

    Full Text Available Accurate measurements of the transverse beam properties are essential to understand and optimize particle beams. We present an optimized method that uses three quadrupole magnets and one profile monitor to measure the full 4D transverse matrix of the beam. The method has been applied to the SwissFEL Injector Test Facility (SITF at the Paul Scherrer Institute (Villigen. The SITF is the principal test bed and demonstration plant for the SwissFEL project, which aims at realizing a hard-x-ray free-electron laser in 2017. Simulations, measurements, and results of cross-plane coupling correction are presented.

  11. Measurements of Linac4 H(-) ion source beam with a magnetized Einzel lens electron dump.

    Science.gov (United States)

    Midttun, Øystein; Lettry, Jacques; Scrivens, Richard

    2014-02-01

    Linac4 is a part of the upgrade of CERN's accelerator complex for increased luminosity in the Large Hadron Collider (LHC). A new system to extract the ion beam from the plasma generator has been designed and tested, in order to improve the reliability and beam optics of the pulsed H(-) ion source. This paper presents the successfully implemented extraction system and three different beam measurements. The simulations compare well to the measurements and show that the plasma density was too low for the extraction system design during the measurements.

  12. Measurements of Linac4 H$^{-}$ ion source beam with a magnetized Einzel lens electron dump

    CERN Document Server

    Midttun, O; Scrivens, R

    2014-01-01

    Linac4 is a part of the upgrade of CERN’s accelerator complex for increased luminosity in the LHC. A new system to extract the ion beam from the plasma generator has been designed and tested, in order to improve the reliability and beam optics of the pulsed H- ion source. This paper presents the successfully implemented extraction system and three different beam measurements. The simulations compare well to the measurements and show that the plasma density was too low for the extraction system design during the measurements.

  13. A 128-channel picoammeter system and its application on charged particle beam current distribution measurements

    CERN Document Server

    Yu, Deyang; Xue, Yingli; Zhang, Mingwu; Cai, Xiaohong; Hu, Jianjun; Dong, Jinmei; Li, Xin

    2015-01-01

    A 128-channel picoammeter system is constructed based on instrumentation amplifiers. Taking the advantages of high electric potential and narrow bandwidth in DC energetic charged beam measurements, current resolution better than 5 fA can be achieved. Two 128-channel Faraday cup arrays are built, and are employed for ion and electron beam current distribution measurements. Tests with 60 keV O3+ ions and 2 keV electrons show that it can provide exact boundaries when a positive charged particle beam current distribution is measured.

  14. Multi turn beam extraction from synchrotron

    Energy Technology Data Exchange (ETDEWEB)

    Tsoupas, Nicholaos

    2017-01-24

    This disclosure relates to apparatuses and methods for the extraction of particle beams while maintaining the energy levels and precision of the particles and the particle beam. Apparatuses and methods for extracting a charged particle beam from a central orbit in a synchrotron are provided, in which a particle beam is deflected from the central orbit. Parts of the deflected particle beam passes through a stripping foil placed in at least parts of the deflected path such that the particles that pass through the foil are stripped of at least one electron. The electron stripped particles and the non-stripped particles may be separated magnetically.

  15. Observation of Femtosecond Bunch Length Using a Transverse Deflecting Structure

    Energy Technology Data Exchange (ETDEWEB)

    Huning, M.; Bolzmann, A.; Schlarb, H.; /DESY; Frisch, J.; McCormick, D.; Ross, M.; Smith, T.; /SLAC; Rossbach, J.; /Hamburg U.

    2005-12-14

    The design of the VUV-FEL at DESY demands bunch lengths in the order of 50 fs and below. For the diagnostic of such very short bunches a transverse deflecting RF structure (LOLA) has been installed which streaks the beam according to the longitudinal distribution. Tests in the VUV-FEL yielded a rich substructure of the bunches. The most pronounced peak in the has a rms length of approximately 50 fs during FEL operation and below 20 fs FWHM at maximum compression. Depending on the transverse focusing a resolution well below 50 fs was achieved.

  16. Linearly polarised photon beams at ELSA and measurement of the beam asymmetry in π0_{} photoproduction off the proton

    Science.gov (United States)

    Elsner, D.; Bantes, B.; Bartholomy, O.; Bayadilov, D. E.; Beck, R.; Beloglazov, Y. A.; Castelijns, R.; Crede, V.; Ehmanns, A.; Essig, K.; Ewald, R.; Fabry, I.; Frommberger, F.; Fornet-Ponse, K.; Fuchs, M.; Funke, C.; Gridnev, A. B.; Gutz, E.; Hillert, W.; Höffgen, S.; Hoffmeister, P.; Horn, I.; Jaegle, I.; Junkersfeld, J.; Kalinowsky, H.; Klein, Frank; Klein, Friedrich; Klempt, E.; Konrad, M.; Kotulla, M.; Krusche, B.; Löhner, H.; Lopatin, I. V.; Lotz, J.; Lugert, S.; Menze, D.; Mertens, T.; Messchendorp, J. G.; Metag, V.; Morales, C.; Nanova, M.; Novinski, D. V.; Novotny, R.; Ostrick, M.; Pant, L. M.; van Pee, H.; Pfeiffer, M.; Sarantsev, A. V.; Schmidt, C.; Schmieden, H.; Schoch, B.; Shende, S.; Süle, A.; Sumachev, V. V.; Szczepanek, T.; Thoma, U.; Trnka, D.; Walther, D.; Weinheimer, C.; Wendel, C.

    2009-03-01

    At the electron accelerator ELSA a linearly polarised tagged photon beam is produced by coherent bremsstrahlung off a diamond crystal. Orientation and energy range of the linear polarisation can be deliberately chosen by accurate positioning of the crystal with a goniometer. The degree of polarisation is determined by the form of the scattered electron spectrum. Good agreement between experiment and expectations on the basis of the experimental conditions is obtained. Polarisation degrees of ensuremath P_{γ}=40 % are typically achieved at half of the primary electron energy. The determination of ensuremath P_{γ} is confirmed by measuring the beam asymmetry, Σ , in π0_{} photoproduction and by a comparison of the results to independent measurements using laser backscattering.

  17. A small-gap electrostatic micro-actuator for large deflections.

    Science.gov (United States)

    Conrad, Holger; Schenk, Harald; Kaiser, Bert; Langa, Sergiu; Gaudet, Matthieu; Schimmanz, Klaus; Stolz, Michael; Lenz, Miriam

    2015-12-11

    Common quasi-static electrostatic micro actuators have significant limitations in deflection due to electrode separation and unstable drive regions. State-of-the-art electrostatic actuators achieve maximum deflections of approximately one third of the electrode separation. Large electrode separation and high driving voltages are normally required to achieve large actuator movements. Here we report on an electrostatic actuator class, fabricated in a CMOS-compatible process, which allows high deflections with small electrode separation. The concept presented makes the huge electrostatic forces within nanometre small electrode separation accessible for large deflections. Electrostatic actuations that are larger than the electrode separation were measured. An analytical theory is compared with measurement and simulation results and enables closer understanding of these actuators. The scaling behaviour discussed indicates significant future improvement on actuator deflection. The presented driving concept enables the investigation and development of novel micro systems with a high potential for improved device and system performance.

  18. Analisis Struktur Balok Non Prismatis Menggunakan Metode Persamaan Slope – Deflection

    Directory of Open Access Journals (Sweden)

    Agus Setiawan

    2011-12-01

    Full Text Available Slope – deflection equation method is an analysis method to solve statically indeterminate structure. This method is a simple technique to analyze continuous beam, either prismatic or non prismatic. The technique for analyzing non prismatic beam is based on the prismatic beam concept, but with the introduce of some modification coefficient. These coefficients are available in some textbook discussing about structural analysis. This research has an objective to compare the analysis result of a continuous non prismatic beam, with slope – deflection equation method, and result from a structural analysis program (i.e. SAP 2000 v.11.00. The internal moment at the joints produced from this two method will be compared each other. The results show that there is a small difference resulted in internal moment, obtained from hand calculation with slope – deflection method and from software output. The differences resulted from this two techniques are 2 up to 6%. Based on this result it can be stated that slope-deflection method can be used to analyze statically indeterminate nonprismatic beam with some modification factors. The result obtained is nearly the same with one obtained from commercial softwares. 

  19. Wide-aperture laser beam measurement using transmission diffuser: errors modeling

    Science.gov (United States)

    Matsak, Ivan S.

    2015-06-01

    Instrumental errors of measurement wide-aperture laser beam diameter were modeled to build measurement setup and justify its metrological characteristics. Modeled setup is based on CCD camera and transmission diffuser. This method is appropriate for precision measurement of large laser beam width from 10 mm up to 1000 mm. It is impossible to measure such beams with other methods based on slit, pinhole, knife edge or direct CCD camera measurement. The method is suitable for continuous and pulsed laser irradiation. However, transmission diffuser method has poor metrological justification required in field of wide aperture beam forming system verification. Considering the fact of non-availability of a standard of wide-aperture flat top beam modelling is preferred way to provide basic reference points for development measurement system. Modelling was conducted in MathCAD. Super-Lorentz distribution with shape parameter 6-12 was used as a model of the beam. Using theoretical evaluations there was found that the key parameters influencing on error are: relative beam size, spatial non-uniformity of the diffuser, lens distortion, physical vignetting, CCD spatial resolution and, effective camera ADC resolution. Errors were modeled for 90% of power beam diameter criteria. 12-order Super-Lorentz distribution was primary model, because it precisely meets experimental distribution at the output of test beam forming system, although other orders were also used. The analytic expressions were obtained analyzing the modelling results for each influencing data. Attainability of <1% error based on choice of parameters of expression was shown. The choice was based on parameters of commercially available components of the setup. The method can provide up to 0.1% error in case of using calibration procedures and multiple measurements.

  20. Beam emittance measurements and simulations of injector line for radio frequency quadrupole

    Science.gov (United States)

    Mathew, Jose V.; Rao, S. V. L. S.; Pande, Rajni; Singh, P.

    2015-07-01

    A 400 keV deuteron (D+) radio frequency quadrupole (RFQ) accelerator has been designed, built, and commissioned at the Bhabha Atomic Research Centre, India. A beam line has been developed for injecting deuterons into the 400 keV RFQ. This comprises of a RF plasma ion source and a low energy beam transport (LEBT) system, consisting of two solenoid magnets and two steerer magnets. The ion source is characterized in terms of transverse beam emittance. A slit-wire scanner based emittance measurement setup has been developed for the transverse emittance measurements of H+ and D+ beams. The measured emittance values are found to be well within the acceptance value for the RFQ. These measured emittance parameters are used to optimize the solenoid fields in LEBT to match the beam from the ion source to RFQ. TRACEWIN simulation code is used for the beam transport simulations. The simulations show 99% transmission of D+ beam through the RFQ, while 95% transmission has been measured experimentally.

  1. Single-pulse and multipulse longitudinal phase space and temperature measurements of an intense ion beam

    Science.gov (United States)

    Coleman, J. E.; Seidl, P. A.; Bieniosek, F. M.; Leitner, M. A.; Lidia, S. M.; Vay, J. L.; Waldron, W. L.; Grote, D. P.; Welch, D. R.

    2012-07-01

    Longitudinal phase space and temperature measurements were conducted on a 2-3μs long, singly charged K+ ion bunch with an ion energy of ˜0.3MeV and current of 30 mA. The principal objective of these experiments was to measure the longitudinal beam dynamics and study the limits of axial compression. The differences between the measured beam energy, longitudinal beam dynamics, and the amplitude and time history of the Marx voltage waveform were all quantified. Longitudinal phase space measurements indicate a slight chromaticity (<1%) in the beam from head to tail. Record low longitudinal temperatures of Tz=2-4×10-2eV were measured for a beam bunch of this intensity with negligible effects from neutralizing the beam space charge with a background plasma. A qualitative comparison of experimental and calculated results are presented, which include time resolved longitudinal distributions, and phase space of the beam at 430 cm.

  2. Extending Bragg peak of heavy ion beam and melanoma cell inactivation measurement

    Institute of Scientific and Technical Information of China (English)

    LiQiang; WeiZeng-Quan; 等

    1998-01-01

    A rotating range modulator was designed and manufactured.which is applied to extend Bragg peak of heavy ion beam.Bragg curves of 75MeV/u 16O and 75MeV/u 12C ion beams through this range modulator were measured respectively and two evident spread-out Bragg peaks corresponding to the modulated beams above are shown.In addition,inactivation effect of the modulated 75MeV/u 16O ion beam at nine different penetration depths on melanoma cells(B16) was measured.Results indicate that lethal effects at the spread-out Bragg peak region are larger than at the plateau of the particle beam entrance.

  3. Nonparaxial multi-Gaussian beam models and measurement models for phased array transducers.

    Science.gov (United States)

    Zhao, Xinyu; Gang, Tie

    2009-01-01

    A nonparaxial multi-Gaussian beam model is proposed in order to overcome the limitation that paraxial Gaussian beam models lose accuracy in simulating the beam steering behavior of phased array transducers. Using this nonparaxial multi-Gaussian beam model, the focusing and steering sound fields generated by an ultrasonic linear phased array transducer are calculated and compared with the corresponding results obtained by paraxial multi-Gaussian beam model and more exact Rayleigh-Sommerfeld integral model. In addition, with help of this novel nonparaxial method, an ultrasonic measurement model is provided to investigate the sensitivity of linear phased array transducers versus steering angles. Also the comparisons of model predictions with experimental results are presented to certify the accuracy of this provided measurement model.

  4. Electro-optical Measurements of Ultrashort 45 MeV Electron Beam Bunches

    CERN Document Server

    Tsang, Thomas; Kowalski, L A; Larsen, R; Lazarus, D M; Nikas, D; Ozben, C; Semertzidis, Y K; Srinivasan-Rao, T

    2000-01-01

    We have measured the temporal duration of 45 MeV picosecond electron beam bunches using a noninvasive electro-optical (EO) technique. The amplitude of the EO modulation was found to increase linearly with electron beam charge and decrease inversely with distance from the electron beam. The risetime of the temporal signal was limited by our detection system to ~70ps. The EO signal due to ionization caused by the electrons traversing the EO crystal was also observed. It has a distinctively long decay time constant and signal polarity opposite to that due to the field induced by the electron beam. The electro-optical technique may be ideal for the measurement of bunch length of femtosecond, relativistic, high energy, charged, particle beams.

  5. Strength Modeling of Reinforced Concrete Beam with Externally Bonded FRP Reinforcement

    Directory of Open Access Journals (Sweden)

    N. Pannirselvam

    2008-01-01

    Full Text Available This research study presents the evaluation of the structural behaviour of reinforced concrete beams with externally bonded Fibre Reinforced Polymer (FRP reinforcements. Three different steel ratios with two different Glass Fibre Reinforced Polymer (GFRP types and two different thicknesses in each type of GFRP were used. Totally fifteen rectangular beams of 3 m length were cast. Three rectangular beams were used as reference beam (Control Beams and the remaining were fixed with GFRP laminates on the soffit of the rectangular beam. The variables considered for the study includes longitudinal steel ratio, type of GFRP laminates, thickness of GFRP laminates and composite ratios. Flexural test, using simple beam with third-point loading was adopted to study the performance of FRP plated beams interms flexural strength, deflection, ductility and was compared with the unplated beams. The test results show that the beams strengthened with GFRP laminates exhibit better performance. The flexural strength and ductility increase with increase in thickness of GFRP plate. The increase in first crack loads was up to 88.89% for 3 mm thick WRGFRP plates and 100.00% for 5 mm WRGFRP plated beams and increase in ductility interms of energy and deflection was found to be 56.01 and 64.69% respectively with 5 mm thick GFRP plated beam. Strength models were developed for predicting the flexural strength (ultimate load, service load and ductility of FRP beams. The strength model developed give prediction matching the measurements.

  6. Electrical shielding box measurement of the negative hydrogen beam from Penning ion gauge ion source.

    Science.gov (United States)

    Wang, T; Yang, Z; Dong, P; long, J D; He, X Z; Wang, X; Zhang, K Z; Zhang, L W

    2012-06-01

    The cold-cathode Penning ion gauge (PIG) type ion source has been used for generation of negative hydrogen (H(-)) ions as the internal ion source of a compact cyclotron. A novel method called electrical shielding box dc beam measurement is described in this paper, and the beam intensity was measured under dc extraction inside an electrical shielding box. The results of the trajectory simulation and dc H(-) beam extraction measurement were presented. The effect of gas flow rate, magnetic field strength, arc current, and extraction voltage were also discussed. In conclusion, the dc H(-) beam current of about 4 mA from the PIG ion source with the puller voltage of 40 kV and arc current of 1.31 A was extrapolated from the measurement at low extraction dc voltages.

  7. Measured Radiation and Background Levels During Transmission of Megawatt Electron Beams Through Millimeter Apertures

    Energy Technology Data Exchange (ETDEWEB)

    Alarcon, Ricardo [Arizona State University, Glendale, AZ (United States); Balascuta, S. [Arizona State University, Glendale, AZ (United States); Benson, Stephen V. [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Bertozzi, William [Massachusetts Institute of Technology, Cambridge, MA (United States); Boyce, James R. [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Cowan, Ray [Massachusetts Institute of Technology, Cambridge, MA (United States); Douglas, David R. [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Evtushenko, Pavel [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Fisher, P. [Massachusetts Institute of Technology, Cambridge, MA (United States); Ihloff, Ernest E. [Hampton University, Hampton, VA (United States); Kalantarians, Narbe [Hampton University, Hampton, VA (United States); Kelleher, Aidan Michael [Massachusetts Institute of Technology, Cambridge, MA (United States); Krossler, W. J. [William and Mary College, Williamsburg, VA (United States); Legg, Robert A. [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Long, Elena [University of New Hampshire, Durham, NH (United States); Milner, Richard [Massachusetts Institute of Technology, Cambridge, MA (United States); Neil, George R. [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Ou, Longwu [Massachusetts Institute of Technology, Cambridge, MA (United States); Schmookler, Barack Abraham [Massachusetts Institute of Technology, Cambridge, MA (United States); Tennant, Christopher D. [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Tschalar, C. [Massachusetts Institute of Technology, Cambridge, MA (United States); Williams, Gwyn P. [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Zhang, Shukui [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States)

    2013-11-01

    We report measurements of photon and neutron radiation levels observed while transmitting a 0.43 MW electron beam through millimeter-sized apertures and during beam-off, but accelerating gradient RF-on, operation. These measurements were conducted at the Free-Electron Laser (FEL) facility of the Jefferson National Accelerator Laboratory (JLab) using a 100 MeV electron beam from an energy-recovery linear accelerator. The beam was directed successively through 6 mm, 4 mm, and 2 mm diameter apertures of length 127 mm in aluminum at a maximum current of 4.3 mA (430 kW beam power). This study was conducted to characterize radiation levels for experiments that need to operate in this environment, such as the proposed DarkLight Experiment. We find that sustained transmission of a 430 kW continuous-wave (CW) beam through a 2 mm aperture is feasible with manageable beam-related backgrounds. We also find that during beam-off, RF-on operation, multipactoring inside the niobium cavities of the accelerator cryomodules is the primary source of ambient radiation when the machine is tuned for 130 MeV operation.

  8. Measured Radiation and Background Levels During Transmission of Megawatt Electron Beams Through Millimeter Apertures

    CERN Document Server

    Alarcon, R; Benson, S.V.; Bertozzi, W.; Boyce, J.R.; Cowan, R.; Douglas, D.; Evtushenko, P.; Fisher, P.; Ihloff, E.; Kalantarians, N.; Kelleher, A.; Kossler, W.J.; Legg, R.; Long, E.; Milner, R.G.; Neil, G.R.; Ou, L.; Schmookler, B.; Tennant, C.; TschaläR, C.; Williams, G.P.; Zhang, S.

    2013-01-01

    We report measurements of photon and neutron radiation levels observed while transmitting a 0.43 MW electron beam through millimeter-sized apertures and during beam-off, but accelerating gradient RF-on, operation. These measurements were conducted at the Free-Electron Laser (FEL) facility of the Jefferson National Accelerator Laboratory (JLab) using a 100 MeV electron beam from an energy-recovery linear accelerator. The beam was directed successively through 6 mm, 4 mm, and 2 mm diameter apertures of length 127 mm in aluminum at a maximum current of 4.3 mA (430 kW beam power). This study was conducted to characterize radiation levels for experiments that need to operate in this environment, such as the proposed DarkLight Experiment. We find that sustained transmission of a 430 kW continuous-wave (CW) beam through a 2 mm aperture is feasible with manageable beam-related backgrounds. We also find that during beam-off, RF-on operation, multipactoring inside the niobium cavities of the accelerator cryomodules is ...

  9. Optical measurement of torque exerted on an elongated object by a non-circular laser beam

    CERN Document Server

    Parkin, S J; Heckenberg, N R; Rubinsztein-Dunlop, H; Parkin, Simon J.; Nieminen, Timo A.; Heckenberg, Norman R.; Rubinsztein-Dunlop, Halina

    2004-01-01

    We have developed a scheme to measure the optical torque, exerted by a laser beam on a phase object, by measuring the orbital angular momentum of the transmitted beam. The experiment is a macroscopic simulation of a situation in optical tweezers, as orbital angular momentum has been widely used to apply torque to microscopic objects. A hologram designed to generate LG02 modes and a CCD camera are used to detect the orbital component of the beam. Experimental results agree with theoretical numerical calculations, and the strength of the orbital component suggest its usefulness in optical tweezers for micromanipulation.

  10. Absorbed dose measurements in the build-up region of flattened versus unflattened megavoltage photon beams.

    Science.gov (United States)

    De Puysseleyr, Annemieke; Lechner, Wolfgang; De Neve, Wilfried; Georg, Dietmar; De Wagter, Carlos

    2016-06-01

    This study evaluated absorbed dose measurements in the build-up region of conventional (FF) versus flattening filter-free (FFF) photon beams. The absorbed dose in the build-up region of static 6 and 10MV FF and FFF beams was measured using radiochromic film and extrapolation chamber dosimetry for single beams with a variety of field sizes, shapes and positions relative to the central axis. Removing the flattening filter generally resulted in slightly higher relative build-up doses. No considerable impact on the depth of maximum dose was found. Copyright © 2016. Published by Elsevier GmbH.

  11. Noninvasive measurement of micron electron beam size of high energy using diffraction radiation

    CERN Document Server

    Naumenko, G A

    2003-01-01

    Treatments of the usage of diffraction radiation from the relativistic electrons moving though a conductive slit for the transverse beam size measurement encounter hard limitation of the method sensitivity for the electron energy larger than 1 GeV. We consider in this article a possibility of application of the artificial phase shift, which can take place when transverse electron position varies. This allows us to realize the measurements of transverse size of supper-relativistic electron beams with the small emittance.

  12. Velocity distribution measurements in atomic beams generated using laser induced back-ablation

    CERN Document Server

    Denning, A; Lee, S; Ammonson, M; Bergeson, S D

    2008-01-01

    We present measurements of the velocity distribution of calcium atoms in an atomic beam generated using a dual-stage laser back-ablation apparatus. Distributions are measured using a velocity selective Doppler time-of-flight technique. They are Boltzmann-like with rms velocities corresponding to temperatures above the melting point for calcium. Contrary to a recent report in the literature, this method does not generate a sub-thermal atomic beam.

  13. Large Deflections of Elastic Rectangular Plates

    Science.gov (United States)

    Razdolsky, A. G.

    2015-11-01

    It is known that elastic large deflections of thin plates are governed by von Karman nonlinear equations. The analytical solution of these equations in the general case is unfeasible. Samuel Levy, in 1942, showed that large deflections of the rectangular plate can be expressed as a double series of sine-shaped harmonics (deflection harmonics). However, this method gave no way of creating the computer algorithm of solving the problem. The stress function expression taken in the Levy's method must be revised to find the approach that takes into account of all possible products of deflection coefficients. The algorithm of solving the problem for the rectangular plate with an arbitrary aspect ratio under the action of the lateral distributed load is reported in this paper. The approximation of the plate deflection is taken in the form of double series proposed by Samuel Levy. However, the expression for the stress function is presented in the form that incorporates products of deflection coefficients in the explicit form in distinction to the Levy's expression. The number of harmonics in the deflection expression may be arbitrary. The algorithm provides composing the system of governing cubic equations, which includes the deflection coefficients in the explicit form. Solving the equation system is based on using the principle of minimum potential energy. A method of the gradient descent is applied to find the equilibrium state of the plate as the minimum point of the potential energy. A computer program is developed on the basis of the present algorithm. Numerical examples carried out for the plate model with 16 deflection harmonics illustrate the potentialities of the program. The results of solving the examples are presented in the graphical form for the plates with a different aspect ratio and may be used under designing thin-walled elements of airplane and ship structures.

  14. Development of High Power Electron Beam Measuring and Analyzing System for Microwave Vacuum Electron Devices

    Science.gov (United States)

    Ruan, C. J.; Wu, X. L.; Li, Q. S.; Li, C. S.

    The measurement and analysis of high power electron beam during its formation and transmission are the basic scientific problems and key techniques for the development of high performance microwave vacuum electron devices, which are widely used in the fields of military weapon, microwave system and scientific instruments. In this paper, the dynamic parameters measurement and analysis system being built in Institute of Electronics, Chinese Academy of Sciences (IECAS) recently are introduced. The instrument are designed to determine the cross-section, the current density, and the energy resolution of the high power electron beam during its formation and transmission process, which are available both for the electron gun and the electron optics system respectively. Then the three dimension trajectory images of the electron beam can be rebuilt and display with computer controlled data acquisition and processing system easily. Thus, much more complicated structures are considered and solved completely to achieve its detection and analysis, such as big chamber with 10-6 Pa high vacuum system, the controlled detector movement system in axis direction with distance of 600 mm inside the vacuum chamber, the electron beam energy analysis system with high resolution of 0.5%, and the electron beam cross-section and density detector using the YAG: Ce crystal and CCD imaging system et al. At present, the key parts of the instrument have been finished, the cross-section experiment of the electron beam have been performed successfully. Hereafter, the instrument will be used to measure and analyze the electron beam with the electron gun and electron optics system for the single beam and multiple beam klystron, gyrotron, sheet beam device, and traveling wave tube etc. thoroughly.

  15. Numerical Simulation Study on the Surface Deflection of Cylindrical Shallow Shell

    Institute of Scientific and Technical Information of China (English)

    XING Zhongwen; BAO Jun; LIU Zhongyuan; YANG Yuying; SUN Zhenzhong

    2006-01-01

    The increasing applications of new materials such as high strength low alloy (HSAL) steels and aluminum alloy sheets have lead to greater focus on the surface deflections of auto body panels in the automobile industry in recent years. The finite element models of cylindrical shallow shell that can represent auto body panels are established. Numerical simulations of forming and unloading of cylindrical shallow shell are carried out. And a measurement and evaluation method of the surface deflection is introduced. The simulations of surface deflections with various blank holding forces (BHF) show great agreement with the experimental results. The influence laws of sheet thickness and material properties such as yield strength σs, strain-hardening exponent n, anisotropy parameter r and strength coefficient k on the surface deflection are achieved by simulations, which give a basic reference for controlling surface deflections.

  16. Ocean Lidar Measurements of Beam Attenuation and a Roadmap to Accurate Phytoplankton Biomass Estimates

    Directory of Open Access Journals (Sweden)

    Hu Yongxiang

    2016-01-01

    On July 17, 2014, the CALIPSO satellite was tilted 30° off-nadir for one nighttime orbit in order to minimize ocean surface backscatter and demonstrate the lidar ocean subsurface measurement concept from space. Depolarization ratios of ocean subsurface backscatter are measured accurately. Beam attenuation coefficients computed from the depolarization ratio measurements compare well with empirical estimates from ocean color measurements. We further verify the beam attenuation coefficient retrievals using aircraft-based high spectral resolution lidar (HSRL data that are collocated with in-water optical measurements.

  17. High resolution acoustic measurement system and beam pattern reconstruction method for bat echolocation emissions.

    Science.gov (United States)

    Gaudette, Jason E; Kloepper, Laura N; Warnecke, Michaela; Simmons, James A

    2014-01-01

    Measurements of the transmit beam patterns emitted by echolocating bats have previously been limited to cross-sectional planes or averaged over multiple signals using sparse microphone arrays. To date, no high-resolution measurements of individual bat transmit beams have been reported in the literature. Recent studies indicate that bats may change the time-frequency structure of their calls depending on the task, and suggest that their beam patterns are more dynamic than previously thought. To investigate beam pattern dynamics in a variety of bat species, a high-density reconfigurable microphone array was designed and constructed using low-cost ultrasonic microphones and custom electronic circuitry. The planar array is 1.83 m wide by 1.42 m tall with microphones positioned on a 2.54 cm square grid. The system can capture up to 228 channels simultaneously at a 500 kHz sampling rate. Beam patterns are reconstructed in azimuth, elevation, and frequency for visualization and further analysis. Validation of the array measurement system and post-processing functions is shown by reconstructing the beam pattern of a transducer with a fixed circular aperture and comparing the result with a theoretical model. To demonstrate the system in use, transmit beam patterns of the big brown bat, Eptesicus fuscus, are shown.

  18. Optics measurement and correction during beam acceleration in the Relativistic Heavy Ion Collider

    Energy Technology Data Exchange (ETDEWEB)

    Liu, C. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Marusic, A. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Minty, M. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.

    2014-09-09

    To minimize operational complexities, setup of collisions in high energy circular colliders typically involves acceleration with near constant β-functions followed by application of strong focusing quadrupoles at the interaction points (IPs) for the final beta-squeeze. At the Relativistic Heavy Ion Collider (RHIC) beam acceleration and optics squeeze are performed simultaneously. In the past, beam optics correction at RHIC has taken place at injection and at final energy with some interpolation of corrections into the acceleration cycle. Recent measurements of the beam optics during acceleration and squeeze have evidenced significant beta-beats which if corrected could minimize undesirable emittance dilutions and maximize the spin polarization of polarized proton beams by avoidance of higher-order multipole fields sampled by particles within the bunch. In this report the methodology now operational at RHIC for beam optics corrections during acceleration with simultaneous beta-squeeze will be presented together with measurements which conclusively demonstrate the superior beam control. As a valuable by-product, the corrections have minimized the beta-beat at the profile monitors so reducing the dominant error in and providing more precise measurements of the evolution of the beam emittances during acceleration.

  19. Beam dumping ghost signals in electric sweep scanners

    Energy Technology Data Exchange (ETDEWEB)

    Stockli, M.P.; /SNS Project, Oak Ridge /Tennessee U.; Leitner, M.; /LBL, Berkeley; Moehs, D.P.; /Fermilab; Keller, R.; /LBL, Berkeley; Welton, R.F.; /SNS Project, Oak Ridge

    2004-12-01

    Over the last 20 years many labs started to use Allison scanners to measure low-energy ion beam emittances. We show that large trajectory angles produce ghost signals due to the impact of the beamlet on the electric deflection plates. The strength of the ghost signal is proportional to the amount of beam entering the scanner. Depending on the ions and their velocity, ghost signals can have the opposite polarity as the main beam signals or the same polarity. These ghost signals are easily overlooked because they partly overlap the real signals, they are mostly below the 1% level, and they are often hidden in the noise. However, they cause significant errors in emittance estimates because they are associated with large trajectory angles. The strength of ghost signals, and the associated errors, can be drastically reduced with a simple modification of the deflection plates.

  20. Remote Estimation of Collimator Jaw Damages With Sounds Measurements During Beam Impacts

    CERN Document Server

    Deboy, D; Aberle, O; Carra, F; Cauchi, M; Lendaro, J; Masi, A; Redaelli, S

    2013-01-01

    Irregular hits of high-intensity LHC beams on collimators can lead to severe damage of the collimator jaws. The identification of damaged collimator jaws by observation of beam measurements is challenging: online loss measurements at the moment of the impacts can be tricky and degradation of the overall performance from single collimator damage can be difficult to measure. Visual inspections are excluded because collimator jaws are enclosed in vacuum tanks without windows. However, the sound generated during the beam impact can be used to give an estimate of the damage level. In 2012, high-intensity beam comparable to a full nominal LHC bunch at 7 TeV was shot on a tertiary type LHC collimator at the HiRadMat test facility at CERN. The paper presents results from sound recordings of this experiment.

  1. Arc Deflection Length Affected by Transverse Rotating Magnetic Field with Lateral Gas

    Science.gov (United States)

    Shiino, Toru; Ishii, Yoko; Yamamoto, Shinji; Iwao, Toru; High Current Energy Laboratory (HiCEL) Team

    2016-10-01

    Gas metal arc welding using shielding gas is often used in the welding industry. However, the arc deflection affected by lateral gas is problem because of inappropriate heat transfer. Shielding gas is used in order to prevent the instability affected by the arc deflection. However, the shielding gas causes turbulence, then blowhole of weld defect occurs because the arc affected by the instability is contaminated by the air. Thus, the magnetic field is applied to the arc in order to stabilize the arc using low amount of shielding gas. The method of applying the transverse rotating magnetic field (RMF) to the arc is one of the methods to prevent the arc instability. The RMF drives the arc because of electromagnetic force. The driven arc is considered to be prevented to arc deflection of lateral gas because the arc is restrained by the magnetic field because of the driven arc. In addition, it is assume the RMF prevented to the arc deflection of lateral gas from the multiple directions. In this paper, the arc deflection length affected by the RMF with lateral gas was elucidated in order to know the effect of the RMF for arc stabilization. Specifically, the arc deflection length affected by the magnetic frequency and the magnetic flux density is measured by high speed video camera. As a result, the arc deflection length decreases with increasing magnetic frequency, and the arc deflection length increases with increasing the magnetic flux density.

  2. An alpha particle measurement system using an energetic neutral helium beam in ITER (invited).

    Science.gov (United States)

    Sasao, M; Kisaki, M; Kobuchi, T; Tsumori, K; Tanaka, N; Terai, K; Okamoto, A; Kitajima, S; Kaneko, O; Shinto, K; Wada, M

    2012-02-01

    An energetic helium neutral beam is involved in the beam neutralization measurement system of alpha particles confined in a DT fusion plasma. A full size strong-focusing He(+) ion source (2 A, the beam radius of 11.3 mm, the beam energy less than 20 keV). Present strong-focusing He(+) ion source shows an emittance diagram separated for each beamlet of multiple apertures without phase space mixing, despite the space charge of a beamlet is asymmetric and the beam flow is non-laminar. The emittance of beamlets in the peripheral region was larger than that of center. The heat load to the plasma electrode was studied to estimate the duty factor for the ITER application.

  3. Polarized neutron beam properties for measuring parity-violating spin rotation in liquid {sup 4}He

    Energy Technology Data Exchange (ETDEWEB)

    Micherdzinska, A.M., E-mail: amicherd@gwu.ed [Indiana University/IU Center for Exploration of Energy and Matter, Bloomington, IN 47408 (United States); George Washington University, Washington, DC 20052 (United States); Bass, C.D. [Indiana University/IU Center for Exploration of Energy and Matter, Bloomington, IN 47408 (United States); National Institute of Standards and Technology, Gaithersburg, MD 20899 (United States); Bass, T.D. [Indiana University/IU Center for Exploration of Energy and Matter, Bloomington, IN 47408 (United States); Gan, K. [George Washington University, Washington, DC 20052 (United States); Luo, D. [Indiana University/IU Center for Exploration of Energy and Matter, Bloomington, IN 47408 (United States); Markoff, D.M. [North Carolina Central University, Durham, NC 27707 (United States); Mumm, H.P.; Nico, J.S. [National Institute of Standards and Technology, Gaithersburg, MD 20899 (United States); Opper, A.K. [George Washington University, Washington, DC 20052 (United States); Sharapov, E.I. [Joint Institute for Nuclear Research, Dubna 141980 (Russian Federation); Snow, W.M. [Indiana University/IU Center for Exploration of Energy and Matter, Bloomington, IN 47408 (United States); Swanson, H.E. [University of Washington/CENPA, Seattle, WA 98195 (United States); Zhumabekova, V. [Al-Farabi Kazakh National University, Al-Farabi Ave. 71, 050038 Almaty (Kazakhstan)

    2011-03-01

    Measurements of parity-violating neutron spin rotation can provide insight into the poorly understood nucleon-nucleon weak interaction. Because the expected rotation angle per unit length is small (10{sup -7} rad/m), several properties of the polarized cold neutron beam phase space and the neutron optical elements of the polarimeter must be measured to quantify possible systematic effects. This paper presents (1) an analysis of a class of possible systematic uncertainties in neutron spin rotation measurements associated with the neutron polarimetry, and (2) measurements of the relevant neutron beam properties (intensity distribution, energy spectrum, and the product of the neutron beam polarization and the analyzing power as a function of the beam phase space properties) on the NG-6 cold neutron beam-line at the National Institute of Standards and Technology Center for Neutron Research. We conclude that the phase space nonuniformities of the polarimeter in this beam are small enough that a parity-violating neutron spin rotation measurement in n-{sup 4}He with systematic uncertainties at the 10{sup -7} rad/m level is possible.

  4. Polarization measurement of Cs using the pump laser beam

    CERN Document Server

    Fang, Jiancheng; Duan, Lihong; Fan, Wenfeng; Jiang, Liwei

    2015-01-01

    In the optical pumping systems based on the pump-probe arrangement, the spin polarization of the atoms is generally monitored utilizing the probe laser beam, in which way an extra perturbation must be introduced and thus affects the normal operation of the sensors. By investigating the absorption rate of the circularly polarized pump laser, here we demonstrate the feasibility of extracting the electron-spin polarization from the transmitted pump laser intensity. We experimentally validate the method in a spin-exchange relaxation free (SERF) magnetometer and the results are in excellent agreement with the theory. The scheme operates in a silent mode and features a real-time observation. We also study the corresponding magnetic field response of the SERF magnetometer and a term arising from the diffusion effects has been added to the original model to explain the discrepancy of the response.

  5. Orbital deflection of fragments produced through peripheral reactions of heavy nuclei at 290 MeV/nucleon

    Science.gov (United States)

    Momota, S.; Kanazawa, M.; Kitagawa, A.; Sato, S.

    2017-02-01

    The orbital deflection phenomenon of reaction products formed through peripheral reactions of heavy nuclei at intermediate energy is studied to examine the contributions of the Coulomb potential and nuclear potential that act between the projectile and target nuclei. The angular distributions of fragments produced in 1-nucleon removal and exchange reactions of 40Ar and 84Kr beams with C, Al, Nb, Tb, and Au targets at 290 MeV/nucleon were observed. A significant deflection effect was successfully identified in observed angular distributions at energies as low as Ei = 100 MeV/nucleon. The deflection effect increases with the atomic number of the target nuclei. The observed deflection effect is consistently explainable using the classical deflection angle, which is obtained with respect to a simple framework of the Coulomb potential and the real part of the energy-dependent nuclear potential, and the characteristic impact parameter between the projectile and target nuclei.

  6. The Australian MRI-Linac Program: measuring profiles and PDD in a horizontal beam

    Science.gov (United States)

    Begg, J.; George, A.; Alnaghy, S. J.; Causer, T.; Alharthi, T.; Glaubes, L.; Dong, B.; Goozee, G.; Liney, G.; Holloway, L.; Keall, P.

    2017-02-01

    The Australian MRI-Linac consists of a fixed horizontal photon beam combined with a MRI. Commissioning required PDD and profiles measured in a horizontal set-up using a combination of water tank measurements and gafchromic film. To validate the methodology, measurements were performed comparing PDD and profiles measured with the gantry angle set to 0 and 90° on a conventional linac. Results showed agreement to within 2.0% for PDD measured using both film and the water tank at gantry 90° relative to PDD acquired using gantry 0°. Profiles acquired using a water tank at both gantry 0 and 90° showed agreement in FWHM to within 1 mm. The agreement for both PDD and profiles measured at gantry 90° relative to gantry 0° curves indicates that the methodology described can be used to acquire the necessary beam data for horizontal beam lines and in particular, commissioning the Australian MRI-linac.

  7. Full in-beam PET measurements of 62 MeV protons onto a PMMA target

    Energy Technology Data Exchange (ETDEWEB)

    Sportelli, G., E-mail: giancarlo.sportelli@pi.infn.it [Department of Physics “E. Fermi”, University of Pisa, Largo B. Pontecorvo 3, I-56127 Pisa (Italy); Istituto Nazionale di Fisica Nucleare, Sezione di Pisa, Largo B. Pontecorvo 3, I-56127 Pisa (Italy); Straub, K.; Aiello, M.; Attanasi, F.; Belcari, N.; Camarlinghi, N. [Department of Physics “E. Fermi”, University of Pisa, Largo B. Pontecorvo 3, I-56127 Pisa (Italy); Istituto Nazionale di Fisica Nucleare, Sezione di Pisa, Largo B. Pontecorvo 3, I-56127 Pisa (Italy); Cirrone, G.A.P.; Cuttone, G. [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali del Sud, Via S. Sofia 62, I-95125 Catania (Italy); Ferretti, S. [Department of Physics “E. Fermi”, University of Pisa, Largo B. Pontecorvo 3, I-56127 Pisa (Italy); Istituto Nazionale di Fisica Nucleare, Sezione di Pisa, Largo B. Pontecorvo 3, I-56127 Pisa (Italy); Marino, N. [Department of Physics “E. Fermi”, University of Pisa, Largo B. Pontecorvo 3, I-56127 Pisa (Italy); Istituto Nazionale di Fisica Nucleare, Sezione di Pisa, Largo B. Pontecorvo 3, I-56127 Pisa (Italy); Department of Information Engineering, University of Pisa, Via G. Caruso 16, I-56122 Pisa (Italy); Nicolosi, D. [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali del Sud, Via S. Sofia 62, I-95125 Catania (Italy); Romano, F. [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali del Sud, Via S. Sofia 62, I-95125 Catania (Italy); Museo Storico della Fisica e Centro Studi e Ricerche “E. Fermi”, I-00184 Roma Italy (Italy); and others

    2013-08-01

    Positron emission tomography (PET) is a valuable technique to monitor in situ and non-invasively the particle range in ion beam therapy exploiting the beta+ activity produced in nuclear interactions along the beam path within the target volume. Due to the high random rates and dead-time losses induced by the particle spills, as of to date data are usually acquired during beam pauses or after the irradiation. We have developed a new PET prototype with a faster photon discrimination component that reduces the front-end dead time, and a modularized acquisition system that parallelizes the sensitive detector area, so as to enable data acquisition also during therapeutic irradiation (full in-beam measurement). The PET system has been able to sustain the single photon count rates and acquire coincidences during the beam, in conditions of sub-clinical beam currents. A study on the paralyzation conditions and dead time losses under different beam currents is presented and the feasibility of a full in-beam PET scanner is discussed.

  8. Analysis of balance beam deformation in the inertial mass measurement experiment

    Science.gov (United States)

    Fu, Zhuang; Zhang, Zhonghua; Li, Zhengkun; Li, Shisong

    2017-09-01

    This paper provides an analysis of mechanical balance beam deformation in the inertial mass measurement experiment since 2012. The relation between the applied test masses and three types of mechanical elastic deformation of the balance beam, i.e. the changes of rotational inertia, beam length and mass center, are discussed. It is found that changes in the rotational inertia and beam length are high order small quantities of the test mass, and a mechanically optimized balance beam which has good mechanical strength and a light structure is adopted to decrease the influence of the two types of deformation. The mass center change, being proportional to the test mass, has the most impact and can be compensated by a novel mass center compensation approach. Simulations and experiments confirm the effectiveness of the new balance beam and the mass center compensation method. It is emphasized that the analysis of the beam deformation in this paper can also be applied in other experiments where mechanical deformation of the balance beam needs to be considered.

  9. Alaska North-South Deflections (DEFLEC96)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This 2' x 4' surface deflection of the vertical grid for Alaska is the DEFLEC96 model. The computation used about 1.1 million terrestrial and marine gravity data...

  10. Mexico East-West Deflections (DMEX97)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This 2' surface deflection of the vertical grid for Mexico, and North-Central is the DMEX97 model. The computation used about one million terrestrial and marine...

  11. Alaska East-West Deflections (DEFLEC96)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This 2' x 4' surface deflection of the vertical grid for Alaska is the DEFLEC96 model. The computation used about 1.1 millionterrestrial and marine gravity data held...

  12. Mexico North-South Deflections (DMEX97)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This 2' surface deflection of the vertical grid for Mexico, and North-Central is the DMEX97 model. The computation used about one million terrestrial and marine...

  13. Procedure for wind turbine power performance measurement with a two-beam nacelle lidar

    OpenAIRE

    Wagner, Rozenn; Rivera, Rebeca L.; Antoniou, Ioannis; Davoust, Samuel; Friis Pedersen, Troels; Courtney, Michael; Diznabi, Babak

    2013-01-01

    This report describes the main steps to use a two-beam nacelle mounted lidar to measure a wind turbine power curve including the preparation of the measurement campaign, the installation of the lidar on the turbine na-celle, the measurement of the wind speed and the wind direction, and the reporting.

  14. Procedure for wind turbine power performance measurement with a two-beam nacelle lidar

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, R.; Rivera, R.L.; Antoniou, I.; Davoust, S.; Pedersen, Troels F.; Courtney, M.; Diznabi, B.

    2013-01-15

    This report describes the main steps to use a two-beam nacelle mounted lidar to measure a wind turbine power curve including the preparation of the measurement campaign, the installation of the lidar on the turbine nacelle, the measurement of the wind speed and the wind direction, and the reporting. (Author)

  15. Procedure for wind turbine power performance measurement with a two-beam nacelle lidar

    DEFF Research Database (Denmark)

    Wagner, Rozenn; Rivera, Rebeca L.; Antoniou, Ioannis;

    This report describes the main steps to use a two-beam nacelle mounted lidar to measure a wind turbine power curve including the preparation of the measurement campaign, the installation of the lidar on the turbine na-celle, the measurement of the wind speed and the wind direction......, and the reporting....

  16. Flexible core masking technique for beam halo measurements with high dynamic range

    Energy Technology Data Exchange (ETDEWEB)

    Egberts, J [Max Planck Institute for Nuclear Physics, Saupfercheckweg 1, D-69117 Heidelberg (Germany); Welsch, C P, E-mail: Carsten.Welsch@quasar-group.co [Cockcroft Institute, Daresbury Science and Innovation Campus, WA4 4AD Warrington (United Kingdom)

    2010-04-15

    A thorough understanding of halo formation and its possible control is highly desirable for essentially all particle accelerators. Particles outside the beam core are not only lost for further experiments, they are also likely to hit the beam pipe, and activate this, as well as accelerator and experimental components in close proximity, which makes work on the accelerator costly and time consuming. Well established techniques for transverse beam profile measurements of electron or high energy hadron beams are the observation of synchrotron radiation, optical transition radiation or the like. A particular challenge, however, is the detection of particles in the tail regions of the beam distribution in close proximity of the very intense beam core. Results from laboratory measurements on two different devices are presented that might form the technical base of a future beam halo monitor: the novel SpectraCam XDR camera system which has an intrinsically high dynamic range due to its unique pixel design, and a flexible masking technique based on a DMD micro mirror array which allows for a fast mask generation to blank out the central core.

  17. Initial Emittance Measurements of the Fermilab Linac Beam Using the MTA Beamline

    CERN Document Server

    Johnstone, C

    2012-01-01

    The MTA beam line has been specifically designed to facilitate measurements of the Fermilab Linac beam emittance and properties utilizing a long, 10m, element-free straight. Linac beam is extracted downstream of the 400-MeV electrostatic chopper located in the Booster injection line. This chopper cannot be utilized for MTA beam, and therefore the entire Linac beam pulse is directed into the MTA beamline. Pulse length manipulation is provided by the 750-keV electrostatic chopper at the upstream end of the Linac and, using this device, beam can be delivered from 8 {\\mu}sec up to the full 50 {\\mu}sec Linac pulse length. The 10 m emittance measurement straight exploits and begins at the 12' shield wall that separates the MTA Experimental Hall and beamline stub from the Linac enclosure. A quadrupole triplet has been installed upstream of the shield wall in order to focus a large, 1.5-2" (~95% width) beam through the shield wall and onto a profile monitor located at the exit of the shielding. Another profile monito...

  18. Proof of concept demonstration for coherent beam pattern measurements of KID detectors

    Science.gov (United States)

    Davis, Kristina K.; Baryshev, Andrey M.; Jellema, Willem; Yates, Stephen J. C.; Ferrari, Lorenza; Baselmans, Jochem J. A.

    2016-07-01

    Here we summarize the initial results from a complex field radiation pattern measurement of a kinetic inductance detector instrument. These detectors are phase insensitive and have thus been limited to scalar, or amplitude-only, beam measurements. Vector beam scans, of both amplitude and phase, double the information received in comparison to scalar beam scans. Scalar beam measurements require multiple scans at varying distances along the optical path of the receiver to fully constrain the divergence angle of the optical system and locate the primary focus. Vector scans provide this information with a single scan, reducing the total measurement time required for new systems and also limiting the influence of system instabilities. The vector scan can be taken at any point along the optical axis of the system including the near-field, which makes beam measurements possible for large systems at high frequencies where these measurements may be inconceivable to be tested in-situ. Therefore, the methodology presented here should enable common heterodyne analysis for direct detector instruments. In principle, this coherent measurement strategy allows phase dependent analysis to be performed on any direct-detect receiver instrument.

  19. Direct measurement of refracted trajectory of transmitting electron cyclotron beam through plasma on the Large Helical Device

    Directory of Open Access Journals (Sweden)

    Takahashi Hiromi

    2015-01-01

    Full Text Available The electron-cyclotron (EC -beam refraction due to the presence of plasma was investigated in the Large Helical Device. The transmitted-EC-beam measurement system was constructed and the beam pattern on the opposite side of the irradiated surface was measured using an IR camera. Clear dependence of the EC-beam refraction on the electron density was observed and the beam shift in the toroidal direction showed good agreement with the ray-trace calculation of TRAVIS. The influence of the peripheral density profile and the thermal effect on the beam refraction were discussed.

  20. Simultaneous scintillation measurements of coherent and partially coherent beams in an open atmosphere experiment

    Science.gov (United States)

    Efimov, Anatoly; Velizhanin, Kirill; Gelikonov, Grigory

    2014-03-01

    Scintillation indices, probability distribution functions and signal spectra are measured simultaneously for spatially coherent and partially coherent optical beams propagating through various distances in an open atmosphere. The partially coherent beam is produced by coupling the broadband output of a superluminescent diode to a multimode optical fiber. A simple system to adjust the coherence radius by controlling the numerical aperture at the fiber output is implemented. Substantial reduction of the scintillation index and signal fade probability as compared to a slightly diverging coherent Gaussian beam are observed at all propagation distances studied up to 6.5 km.