WorldWideScience

Sample records for beam control system

  1. Proton beam therapy control system

    Science.gov (United States)

    Baumann, Michael A.; Beloussov, Alexandre V.; Bakir, Julide; Armon, Deganit; Olsen, Howard B.; Salem, Dana

    2008-07-08

    A tiered communications architecture for managing network traffic in a distributed system. Communication between client or control computers and a plurality of hardware devices is administered by agent and monitor devices whose activities are coordinated to reduce the number of open channels or sockets. The communications architecture also improves the transparency and scalability of the distributed system by reducing network mapping dependence. The architecture is desirably implemented in a proton beam therapy system to provide flexible security policies which improve patent safety and facilitate system maintenance and development.

  2. The elettra beam line control system

    International Nuclear Information System (INIS)

    Elettra is a third generation Synchrotron Light Source located in Trieste (Italy). It consists of a full energy linac injector and a storage ring with beam energies between 1.5 and 2 GeV. The facility is scheduled to be operational by end 1993. For the whole project 22 beam lines from insertion devices are foreseen, each of them is composed of a large number of measurement and controls instruments, most of them embedded in intelligent devices; in addition each beam line can be considered unique compared to the others, having been designed to provide a different kind of synchrotron radiation. This results in a large not homogenous environment where more than 200,000 physical points have to be controlled. A joint team composed of Softeco Sismat and Digital Equipment has developed a fully automated beam line control system able to give full remote controls, with different kind of access rights, to beam line users and beam line specialists as well as a full integration with experiment control systems. ((orig.))

  3. Electron beam accelerator energy control system

    International Nuclear Information System (INIS)

    A control system has been developed for the energy control of the electron beam accelerator using PLC. The accelerating voltage of 3 MV has been obtained by using parallel coupled voltage multiplier circuit. A autotransformer controlled variable 0-10 KV DC is fed to a tube based push pull oscillator to generate 120 Khz, 10 KV AC. Oscillator output voltage is stepped up to 0-300 KV/AC using a transformer. 0-300 KVAC is fed to the voltage multiplier column to generate the accelerating voltage at the dome 0-3 MV/DC. The control system has been designed to maintain the accelerator voltage same throughout the operation by adjusting the input voltage in close loop. Whenever there is any change in the output voltage either because of beam loading or arcing in the accelerator. The instantaneous accelerator voltage or energy is a direct proportional to 0-10 KVDC obtained from autotransformer. A PLC based control system with user settable energy level has been installed for 3 MeV, EB accelerator. The PLC takes the user defined energy value through a touch screen and compares it to the actual accelerating voltage (obtained using resistive divider). Depending upon the error the PLC generates the pulses to adjust the autotransformer to bring the actual voltage to the set value within the window of error (presently set to +/- 0.1%). (author)

  4. Beam kicker control system for CSR project in Lanzhou

    International Nuclear Information System (INIS)

    The beam kicker system is a key part for beam extraction and injection in ring-like accelerator, which works under high voltage and huge current. This paper introduces the kicker control system based on ARM+DSP+FPGA for CSR project in Lanzhou, which has nanosecond timing precision. ARM mainly completes the control signals with the network communication, and the time control precision for the beam kicker system is performed mainly by FPGA and DSP. The sequence control signals through the optic fiber transmission, synchronous to kicker power supply the voltage to assign uses the signal isolators and ferrites to suppress the disturbance pulses. Scene test has proved that this system can meet beam kicker control's request and work safely and stably. The control system has extracted and injected the CSR beam successfully in October 2007. (authors)

  5. Control system for the text diagnostic neutral beam source

    International Nuclear Information System (INIS)

    A diagnostic neutral beam source (DNB) has been designed, built, and installed on the Texas Experimental Tokamak (TEXT). The control system, presented in this paper, coordinates the functioning of all associated subsystems necessary for neutral beam operation. These include the modulator/regulator, the capacitor bank charging system, the arc and filament supplies, the biased snubber supply, the deflection magnet supply, the suppressor switch, and the Culham vacuum system. The control system architecture is a hierarchical, decentralized, hardwired logic system designed to meet criteria of reliability, modularity, and flexibility

  6. ISABELLE accelerator software, control system, and beam diagnostic philosophy

    International Nuclear Information System (INIS)

    The ISABELLE Project combines two large proton accelerators with two storage rings in the same facility using superconducting magnet technology. This combination leads to severe constraints on beam loss in magnets and involves complex treatment of magnetic field imperfections and correction elements. The consequent demands placed upon beam diagnostics, accelerator model programs, and the computer oriented control system are discussed in terms of an illustrative operation scenario

  7. Neutral beam control systems for the Tandem Mirror Experiment

    International Nuclear Information System (INIS)

    The Tandem Mirror Experiment (TMX) is presently developing the technology and approaches which will be used in larger fusion systems. This paper describes some of the designs which were used in creating the control system for the TMX neutral beams. To create a system of controls that would work near these large, rapid switching current sources required a mixture of different technologies: fiberoptic data transmission, printed circuit and wirewrap techniques, etc

  8. Model calibration and beam control systems for storage rings

    International Nuclear Information System (INIS)

    Electron beam storage rings and linear accelerators are rapidly gaining worldwide popularity as scientific devices for the production of high-brightness synchrotron radiation. Today, everybody agrees that there is a premium on calibrating the storage ring model and determining errors in the machine as soon as possible after the beam is injected. In addition, the accurate optics model enables machine operators to predictably adjust key performance parameters, and allows reliable identification of new errors that occur during operation of the machine. Since the need for model calibration and beam control systems is common to all storage rings, software packages should be made that are portable between different machines. In this paper, we report on work directed toward achieving in-situ calibration of the optics model, detection of alignment errors, and orbit control techniques, with an emphasis on developing a portable system incorporating these tools

  9. DIII-D Neutral Beam control system operator interface

    International Nuclear Information System (INIS)

    A centralized graphical user interface has been added to the DIII-D Neutral Beam (NB) control systems for status monitoring and remote control applications. This user interface provides for automatic data acquisition, alarm detection and supervisory control of the four NB programmable logic controllers (PLC) as well as the Mode Control PLC. These PLCs are used for interlocking, control and status of the NB vacuum pumping, gas delivery, and water cooling systems as well as beam mode status and control. The system allows for both a friendly user interface as well as a safe and convenient method of communicating with remote hardware that formerly required interns to access. In the future, to enable high level of control of PLC subsystems, complete procedures is written and executed at the touch of a screen control panel button. The system consists of an IBM compatible 486 computer running the FIX DMACS trademark for Windows trademark data acquisition and control interface software, a Texas Instruments/Siemens communication card and Phoenix Digital optical communications modules. Communication is achieved via the TIWAY (Texas Instruments protocol link utilizing both fiber optic communications and a copper local area network (LAN). Hardware and software capabilities will be reviewed. Data and alarm reporting, extended monitoring and control capabilities will also be discussed

  10. The system of RF beam control for electron gun

    Science.gov (United States)

    Barnyakov, A. M.; Chernousov, Yu. D.; Ivannikov, V. I.; Levichev, A. E.; Shebolaev, I. V.

    2015-06-01

    The system of RF control of three-electrode electron gun current is described. It consists of a source of microwave signal, coaxial line, coaxial RF switch and RF antenna lead. The system allows one to get the electron beam in the form of bunches with the frequency of the accelerating section to achieve the capture of particles in the acceleration mode close to 100%. The results of calculation and analysis of the elements of the system are presented. Characteristics of the devices are obtained experimentally. The results of using RF control in three-electrode electron gun at electron linear accelerator are described.

  11. The system of RF beam control for electron gun

    International Nuclear Information System (INIS)

    The system of RF control of three-electrode electron gun current is described. It consists of a source of microwave signal, coaxial line, coaxial RF switch and RF antenna lead. The system allows one to get the electron beam in the form of bunches with the frequency of the accelerating section to achieve the capture of particles in the acceleration mode close to 100%. The results of calculation and analysis of the elements of the system are presented. Characteristics of the devices are obtained experimentally. The results of using RF control in three-electrode electron gun at electron linear accelerator are described

  12. Particle beam digital phase control system for COSY

    International Nuclear Information System (INIS)

    Particle accelerators require that the orbit of the charged particles in the vacuum chamber is controlled to fulfil narrow limits. This is done by magnetic deflection systems and exactly adjusted rf-acceleration. Up to now the necessary control-functions were realised with analogue parts. This work describes a digital phase control system that works in real time and is used with the proton accelerator COSY. The physical design of the accelerator sets the accuracy-specifications of the revolution frequency (<1 Hz in the whole range from 400 kHz to 1.6 MHz), the phase-difference (<0.01 ), the signal-to-noise-ratio (<-60 dBc) and the update rate (<1 μs) of the parameters. In a typical operation the beam is first bunched and synchronised to the reference oscillator. After that the beam influences the rf-system with the help of charge detectors and now the rf-systems will be synchronised with the bunched beam. This control-loop is modelled and simulated with PSPICE. (orig.)

  13. Development of beam current control system in RF-knockout slow extraction

    Energy Technology Data Exchange (ETDEWEB)

    Mizushima, K., E-mail: mizshima@nirs.go.jp [Department of Accelerator and Medical Physics, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Graduate School of Science and Technology, Chiba University, Yayoi-cho, Inage-ku, Chiba 263-8522 (Japan); Sato, S.; Shirai, T.; Furukawa, T.; Katagiri, K.; Takeshita, E.; Iwata, Y.; Himukai, T.; Noda, K. [Department of Accelerator and Medical Physics, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan)

    2011-12-15

    A raster scanning method has been developed for cancer therapy at NIRS-HIMAC. This method requires a high-accuracy beam current control and fast beam-on/off switching. We have developed a feedback control system of the beam current with the RF-knockout slow extraction method. The system has allowed a stable response to beam-on/off switching using a feedback control delay function with a beam-current ripple of 7%.

  14. Design of Main Control Console Software in EAST Neutral Beam Injector's Control System for the First Beam Line

    Science.gov (United States)

    Wu, De-Yun; Hu, Chun-Dong; Sheng, Peng; Zhao, Yuan-Zhe; Zhang, Xiao-Dan; Cui, Qing-Long

    2013-10-01

    Neutral beam injector is one of the main plasma heating and plasma current driving methods for experimental advanced superconducting tokomaks (EAST). In order to realize visual operation of EAST neutral beam injector's control system (NBICS), main control console (MCC) is developed to work as the human-machine interface between the NBICS and physical operator. It can meet the requirements of visual control of NBICS by providing a user graphic interface. With the specific algorithms, the setup of power supply sequence is relatively independent and simple. Displaying the real-time feedback of the subsystems provides a reference for operators to monitor the status of the system. The MCC software runs on a Windows system and uses C++ language code while using client/server (C/S) mode, multithreading and cyclic redundancy check technology. The experimental results have proved that MCC provides a stability and reliability operation of NBICS and works as an effective man-machine interface at the same time.

  15. Fluorescent beam profile measurement and control system in HIRFL-CSR

    International Nuclear Information System (INIS)

    The paper introduced the development of fluorescent driving controller and video signal for switching controller based on micro-computer technology in improvement of the beam diagnostic system at HIRFL-CSR. The design structure of the distributed beam profile measurement system based on Web control technique was depicted. (authors)

  16. Control and monitoring system for internal beam diagnostics facility of SCC

    International Nuclear Information System (INIS)

    The first Ion beam will be accelerated in K-500 Superconducting Cyclotron at VECC soon. The acceleration zone employs Main probe and Beam viewer probe for internal beam diagnostics. The ion beam, during acceleration inside the cyclotron, is needed to be maintained in median plane. The deviation of beam at various radial positions is to be monitored by Main-Probe head. The characteristics of beam e.g. size and shape information is required at the time of beam tuning. A Beam Viewer Probe, made of a borescope fitted with a fluorescent plate is used to display the beam characteristics. High resolution probe head driving systems are developed along with VB GUI to control both the drives and monitor the beam properties (e.g. magnitude, deviation, size, shape). This paper describes the control instrumentation and monitoring scheme for main probe and viewer probe. (author)

  17. The CEBAF [Continuous Electron Beam Accelerator Facility] control system architecture

    International Nuclear Information System (INIS)

    The focus of this paper is on CEBAF's computer control system. This control system will utilize computers in a distributed, networked configuration. The architecture, networking and operating system of the computers, and preliminary performance data are presented. We will also discuss the design of the operator consoles and the interfacing between the computers and CEBAF's instrumentation and operating equipment

  18. Indus-2 beam line front end controls using real time operating system

    International Nuclear Information System (INIS)

    Beam Line Front Ends (BLFE) are crucial interfaces between machine user beam lines and INDUS-2 synchrotron radiation source. Twenty-seven beam lines are proposed in INDUS-2 synchrotron facility out of which some are operational by now and many more are about to come. The purpose of these BLFE's is essentially to protect the machine vacuum from beam line failures and vice versa and allow a well co-ordinated and safe usage of machine by its users. For controlling these beam lines, BLFE control system is implemented. The BLFE control system is based on three-layer architecture with equipments connected ate the layer three, Layer two serves the purpose of metadata storage, layer one serves as operator console (GUI). This paper discusses the scheme and architecture of layer two and layer three implementation using RTOS OS-9. The diagnostic features incorporated in the architecture increases the system uptime by quick diagnosis of system faults. (author)

  19. Thermionic gun control system for the CEBAF [Continuous Electron Beam Accelerator Facility] injector

    International Nuclear Information System (INIS)

    The injector for the CEBAF accelerator must produce a high-quality electron beam to meet the overall accelerator specifications. A Hermosa electron gun with a 2 mm-diameter cathode and a control aperture has been chosen as the electron source. This must be controlled over a wide range of operating conditions to meet the beam specifications and to provide flexibility for accelerator commissioning. The gun is controlled using Computer Automated Measurement and Control (CAMAC IEEE-583) technology. The system employs the CAMAC-based control architecture developed at CEBAF. The control system has been tested, and early operating data on the electron gun and the injector beam transport system has been obtained. This system also allows gun parameters to be stored at the operator location, without paralyzing operation. This paper describes the use of this computer system in the control of the CEBAF electron gun. 2 refs., 6 figs., 1 tab

  20. Developing an expert system to control a beam line at the Los Alamos Meson Physics Facility

    International Nuclear Information System (INIS)

    High energy particle experiments require an accelerator as a source of high energy particles. To increase the productivity of an accelerator facility, we wish to develop an expert system to control beam lines. Expert Systems are a branch of Artificial Intelligence where a computer program performs tasks requiring human expertise. Unlike most expert systems we have a physical model underlying our beam line and this model can be used with the expert system to improve performance. The development of the expert system will lead to an increased understanding of the beam line as well as the possibility of state-of-the-art expert system building

  1. Beam transport experiment with a new kicker control system on the HIRFL-CSR

    CERN Document Server

    Wang, Yan-Yu; Luo, Jin-Fu; Zhang, Jian-Chuan; Zhou, Wen-Xiong; Ni, Fa-Fu; Yin, Jun; Yin, Jia; Yuan, You-Jin; Shang-Guan, Jin-Bin

    2015-01-01

    The kicker control system was used for beam extraction and injection between two cooling storage rings (CSRs) at the Heavy Ion Research Facility in Lanzhou (HIRFL). To meet the requirements of special physics experiments, the kicker controller was upgraded. The new controller was designed based on ARM+DSP+FPGA technology and monolithic circuit architecture, which can achieve a precision time delay of 2.5 ns. In September 2014, the new kicker control system was installed in the kicker field, and the test experiment using the system was completed. In addition, a pre-trigger signal was provided by the controller, which was designed to synchronize the beam diagnostic system and physics experiments. Experimental results indicate that the phenomena of "missed kick" and "inefficient kick" were not observed, and the multichannel trigger signals' delay could be adjusted individually for kick power supplies in digitization; thus, the beam transport efficiency was improved compared with that of the original system. The ...

  2. Enhancement of beam pulse controllability for a single-pulse formation system of a cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Kurashima, Satoshi, E-mail: kurashima.satoshi@jaea.go.jp; Miyawaki, Nobumasa; Kashiwagi, Hirotsugu; Okumura, Susumu [Takasaki Advanced Radiation Research Institute, Japan Atomic Energy Agency, 1233 Watanuki, Takasaki, Gunma 370-1292 (Japan); Taguchi, Mitsumasa [Quantum Beam Science Center, Japan Atomic Energy Agency, 1233 Watanuki, Takasaki, Gunma 370-1292 (Japan); Fukuda, Mitsuhiro [Research Center for Nuclear Physics, Osaka University, 10-1 Mihogaoka, Ibaraki, Osaka 567-0047 (Japan)

    2015-07-15

    The single-pulse formation technique using a beam chopping system consisting of two types of high-voltage beam kickers was improved to enhance the quality and intensity of the single-pulse beam with a pulse interval over 1 μs at the Japan Atomic Energy Agency cyclotron facility. A contamination rate of neighboring beam bunches in the single-pulse beam was reduced to less than 0.1%. Long-term purification of the single pulse beam was guaranteed by the well-controlled magnetic field stabilization system for the cyclotron magnet. Reduction of the multi-turn extraction number for suppressing the neighboring beam bunch contamination was achieved by restriction of a beam phase width and precise optimization of a particle acceleration phase. In addition, the single-pulse beam intensity was increased by a factor of two or more by a combination of two types of beam bunchers using sinusoidal and saw-tooth voltage waveforms. Provision of the high quality intense single-pulse beam contributed to improve the accuracy of experiments for investigation of scintillation light time-profile and for neutron energy measurement by a time-of-flight method.

  3. Enhancement of beam pulse controllability for a single-pulse formation system of a cyclotron

    International Nuclear Information System (INIS)

    The single-pulse formation technique using a beam chopping system consisting of two types of high-voltage beam kickers was improved to enhance the quality and intensity of the single-pulse beam with a pulse interval over 1 μs at the Japan Atomic Energy Agency cyclotron facility. A contamination rate of neighboring beam bunches in the single-pulse beam was reduced to less than 0.1%. Long-term purification of the single pulse beam was guaranteed by the well-controlled magnetic field stabilization system for the cyclotron magnet. Reduction of the multi-turn extraction number for suppressing the neighboring beam bunch contamination was achieved by restriction of a beam phase width and precise optimization of a particle acceleration phase. In addition, the single-pulse beam intensity was increased by a factor of two or more by a combination of two types of beam bunchers using sinusoidal and saw-tooth voltage waveforms. Provision of the high quality intense single-pulse beam contributed to improve the accuracy of experiments for investigation of scintillation light time-profile and for neutron energy measurement by a time-of-flight method

  4. Development of a Computer Control System for Heavy Ion Beam Probes

    Science.gov (United States)

    Andersen, J. K.; Roberts, S. L.; Westervelt, E. R.; Schoch, P. M.; Schatz, J. G.

    1996-11-01

    Enhanced computer control of heavy ion beam probes would increase the reproducability of experimental conditions by automation and feedback control of some system parameters. Also, operation from a remote site would then be feasible. Computer control has been implemented on a variety of Rensselaer heavy ion beam probe systems. However, no system to date has allowed complete remote operation. This has been primarily due to the limitations of the user interface. The next generation of HIBP control systems software is being created with National Instruments' graphical language, LabVIEW. The virtual instruments allow detailed monitoring and control of the injected beam conditions. The control and monitoring of the ion beam, including filament current and Pierce, focusing, quadrupole lens, and sweep electrodes' voltages has been tested on RPI's vertical test stand. A feedback routine to focus the beam using the quadrupole lens is currently being developed. When this capability is available, it will be implemented on a heavy ion beam probe diagnostic operating on a magnetic confinement device.

  5. The on-line beam control and diagnosis system of TARN

    International Nuclear Information System (INIS)

    The computer network in TARN is composed of a central main frame computer, two different minicomputers and several microprocessors. It has been used for the beam control and the beam diagnosis; support for adjustment of elements of the transport line and the ring, generation of RF voltage function, measurement of beam profile at RF stacking, on-line measurement of ν:value, and observation of Schottky signal. By the use of this computer system, the operation of TARN has been effectively and steadily performed, and additionally it has contributed to measuring the beam characteristics precisely in the ring. (author)

  6. Computer based diagnostic and control system for a 120 keV neutral beam test stand

    International Nuclear Information System (INIS)

    The computer based system provides data acquisition, analysis, display, archival, and control functions for the 120 KEV test stand IIIa at Lawrence Berkeley Laboratory. The system supports calorimeter arrays and spectrometer diagnostics, controls all power supplies and provides 7 modes of control ranging from manual control with computer monitor to full auto conditioning with an auto sweep capability for parameter variation studies. This paper describes the software structure, I/O techniques, control algorithms, hardware configuration, and system performance. Conclusions based on system performance provide useful insight for design of neutral beam control systems for use on large plasma devices

  7. Control system of magnetic optical element power supplies for some beam channels

    International Nuclear Information System (INIS)

    The control system of the magnetic optical element power supplies for some beam channels of the IHEP accelerator, based on the micro-computer ''Elektronika-60'' and its software are described. The remote control is supplied with three Multidrop Serial Busses (31 consumer per bus). The number of controlled elements can be increased by adding one or more serial busses

  8. Design of Control Server Application Software for Neutral Beam Injection System

    International Nuclear Information System (INIS)

    For the remote control of a neutral beam injection (NBI) system, a software NBIcsw is developed to work on the control server. It can meet the requirements of data transmission and operation-control between the NBI measurement and control layer (MCL) and the remote monitoring layer (RML). The NBIcsw runs on a Linux system, developed with client/server (C/S) mode and multithreading technology. It is shown through application that the software is with good efficiency.

  9. Active trajectory control for a heavy ion beam probe on the compact helical system

    International Nuclear Information System (INIS)

    A 200 keV heavy ion beam probe (HIBP) on the Compact Helical System torsatron/heliotron uses a newly proposed method in order to control complicated beam trajectories in non-axisymmetrical devices. As a result, the HIBP has successfully measured potential profiles of the toroidal helical plasma. The article will describe the results of the potential profile measurements, together with the HIBP hardware system and procedures to realize the method. (author)

  10. Data acquisition and control system for steady state neutral beam injector

    International Nuclear Information System (INIS)

    This paper presents the control system overview, hardware, software and network for Data acquisition and Control system for steady state neutral beam injector (NBIDACS) to be used for heating of plasma in steady state superconducting tokamak (SST-1). The task for NBIDACS is not only to safely deliver 1.7 MW of neutral beams at 55 keV H deg. a period of 1000 s with 16.7% duty cycle but also to acquire the data related to house keeping of the system and its auxiliaries and diagnostics which determine the quality and parameters of the beam. Major issues concerning the design of the system stem from operation duty cycle of 1000 s ON/5000 s OFF. This calls for use of intelligent techniques not only for managing a large amount (100 MB) of data per shot but also to obtain failsafe, reliable control system and to archive the recorded data

  11. A Monitor and Control System for the Synchrotron Radiation Beam Lines at DAΦNE

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    Three synchrotron radiation beam lines have been built on DAΦNE,the Frascati electron-positron accelerator.It is Possible to monitor and control all the elements on the beam lines using a modular network distributed I/O system by National Instrunments (FieldPoint) with Bridge VIEW/Lab VIEW programs,Two of these beam lines have radiation safety problems solved by two independent and redundant systems,using mechanical switches ,and S7-200 PLC's by Siemens.In this article our solution will be described in details.

  12. Global Accelerator Network, Control Systems And Beam Diagnostics

    CERN Document Server

    Raich, U

    2003-01-01

    Falling funds force all accelerator centers to look for new sources of financing and for the most efficient way of implementing new projects. This very often leads to collaborations between institutes scattered around the globe, a problem well known to big high energy physics experiments. The collaborations working on big detectors e.g. for LHC started thinking about detector acquisition and control systems which can be remotely used from their respective home institutes with minimal support on the spot. This idea was taken up by A. Wagner from DESY for the TESLA machine, who proposed the “Global Accelerator Network” (GAN) enabling users from around the world to run an accelerator remotely. Questions around this subject that immediately come to mind Is the GAN only relevant to big labs ? Or is it reasonable e.g. for operators or engineers in charge to do certain manipulations from home? Are our instruments ready for the GAN? Does the fact of being “GAN ready” increa...

  13. Application of object oriented techniques in the TRIUMF beam line 2C control system

    International Nuclear Information System (INIS)

    The KAON Factory central control system study employed a uniform approach to requirements analysis, architectural design and programming based on well established object oriented principles. These principles were applied to the successful analysis, design and implementation of the control system for the TRIUMF Beam Line 2C Solid Target Facility. The specification for this control system was created in collaboration with Beam Line 2C equipment management experts and, once the analysis models were validated, an approach was developed for the direct translation of these models into C code. A commercial real time database was central to this translation, as inter-object data and control flows are implemented by channels in the database. This paper focuses on the experience gained in the use of object oriented techniques during the complete analysis-design-implementation cycle of a working control system and on the utility of implementing such a system using a commercial real time database and graphical interface. (author)

  14. Dynamic boundary controls of a rotating body-beam system with time-varying angular velocity

    OpenAIRE

    Boumediène Chentouf

    2004-01-01

    This paper deals with feedback stabilization of a flexible beam clamped at a rigid body and free at the other end. We assume that there is no damping and the rigid body rotates with a nonconstant angular velocity. To stabilize this system, we propose a feedback law which consists of a control torque applied on the rigid body and either a dynamic boundary control moment or a dynamic boundary control force or both of them applied at the free end of the beam. Then it is ...

  15. Propagation properties of controllable dark-hollow beams through fractional Fourier transform systems

    Institute of Scientific and Technical Information of China (English)

    TANG Bin; LI Rui-peng; JIN Yi; JIANG Mei-ping

    2012-01-01

    Based on the definition of fractional Fourier transform (FrFT) in the cylindrical coordinate system,the propagation properties of a controllable dark-hollow beam (CDHB) are investigated in detail.An analytical formula is derived for the FrFT of a CDHB.By using the derived formula,the properties of a CDHB in the FrFT plane are illustrated numerically.The results show that the properties of the intensity of the beam in the FrFT are closely related to not only the fractional order but also initial beam parameter,beam order and the lens focal length of the optical system for performing FrFT.The derived formula provides an effective and convenient way for analyzing and calculating the FrFT ofa CDHB.

  16. Development of an on-line control system for the RF separated hadron beams to BEBC

    International Nuclear Information System (INIS)

    An on-line control system to tune and monitor separated particle beams to the Big European Bubble Chamber is described. The system includes controls of magnetic elements, collimators, rf-separators, multiwire proportional chambers and scintillation counters. Based on a PDP-8/e computer, the development of this system from a small satellite computer linked to a PDP-15 to a disc-based operating system is described. The hardware layout of the controls and the structure of the employed software are discussed. (Auth.)

  17. Beam transport experiment with a new kicker control system on the HIRFL

    Science.gov (United States)

    Yan-Yu, Wang; De-Tai, Zhou; Jin-Fu, Luo; Jian-Chuan, Zhang; Wen-Xiong, Zhou; Fa-Fu, Ni; Jun, Yin; Jia, Yin; You-Jin, Yuan; Jing-Bin, Shang-Guan

    2016-04-01

    A kicker control system is used for beam extraction and injection between two cooling storage rings (CSRs) at the Heavy Ion Research Facility in Lanzhou (HIRFL). To meet the requirements of special physics experiments, the kicker controller has been upgraded, with a new controller designed based on ARM+DSP+FPGA technology and monolithic circuit architecture, which can achieve a precision time delay of 2.5 ns. In September 2014, the new kicker control system was installed in the kicker field, and the test experiment using the system was completed. In addition, a pre-trigger signal was provided by the controller, which was designed to synchronize the beam diagnostic system and physics experiments. Experimental results indicate that the phenomena of “missed kick” and “inefficient kick” were not observed, and the multichannel trigger signal delay could be adjusted individually for kick power supplies in digitization; thus, the beam transport efficiency was improved compared with that of the original system. The fast extraction and injection experiment was successfully completed based on the new kicker control systems for HIRFL. Supported by National Natural Science Foundation of China (U1232123)

  18. Optimal tracking control of a flexible hub-beam system with time delay

    International Nuclear Information System (INIS)

    In this paper, a new technique of time-delay compensation is proposed for active control of a flexible hub-beam system. The first-order approximation coupling (FOAC) model proposed recently for dynamics of hub-beam systems is used to verify the applicability of this technique. The FOAC model is first linearized to obtain a linearized equation. The linearized equation with time delay is then transformed into a standard form with no time delay by a particular integral transformation. The time-delay controller is designed based on this standard equation using the classical optimal tracking control theory. Since the controller is a function of modal coordinates, a modal filter is presented to estimate the modal coordinates from physical sensor measurements. The effectiveness of the proposed technique for time delay is demonstrated by numerical simulations. Simulation results indicate that a very small time delay may result in instability of the control system if it is not compensated in control design. The proposed time-delay controller is effective in controlling the system even when the maximum time delay for stability without time-delay compensation is greatly exceeded. Moreover, for the system without time delay, the proposed time-delay controller may possibly obtain much better control effectiveness than the controller without time delay

  19. Beam line control system for BARC-TIFR super conducting linac booster

    International Nuclear Information System (INIS)

    LINAC control system is a distributed control system. Hardware is distributed geometrically for RF control and monitoring with four nodes for RF control. Systematic distribution is applied by addition of different node for Beam line instrument control (BLS) which consists of different focussing magnets, steerers and beam diagnostics devices (Faraday cups and BPMs) and magnetic field measurement devices hall probes. All the focussing and diagnostics devices have their built-in microprocessor based electronic interfaces, which can be remotely accessed by RS 232/RS 422 link. The serial devices are connected to three different 16 port RS232 to Ethernet converter switch, which are connected to LINAC lab by Ethernet link. Multilevel software is developed in JAVA, with useful and attractive virtual panel interface provided by monitor and keyboard. (author)

  20. Single-beam water vapor detection system with automatic photoelectric conversion gain control

    Science.gov (United States)

    Zhu, C. G.; Chang, J.; Wang, P. P.; Wang, Q.; Wei, W.; Liu, Z.; Zhang, S. S.

    2014-11-01

    A single-beam optical sensor system with automatic photoelectric conversion gain control is proposed for doing high reliability water vapor detection under relatively rough environmental conditions. Comparing to a dual-beam system, it can distinguish the finer photocurrent variations caused by the optical power drift and provide timely compensation by automatically adjusting the photoelectric conversion gain. This system can be rarely affected by the optical power drift caused by fluctuating ambient temperature or variation of fiber bending loss. The deviation of the single-beam system is below 1.11% when photocurrent decays due to fiber bending loss for bending radius of 5 mm, which is obviously lower than the dual-beam system (8.82%). We also demonstrate the long-term stability of the single-beam system by monitoring a 660 ppm by volume (ppmv) water vapor sample continuously for 24 h. The maximum deviation of the measured concentration during the whole testing period does not exceed 10 ppmv. Experiments have shown that the new system features better reliability and is more apt for remote sensing application which is often subject to light transmission loss.

  1. Thermomagnetic recording and magneto-optic playback system having constant intensity laser beam control

    Science.gov (United States)

    Lewicki, G. W.; Guisinger, J. E. (Inventor)

    1973-01-01

    A system is developed for maintaining the intensity of a laser beam at a constant level in a thermomagnetic recording and magneto-optic playback system in which an isotropic film is heated along a continuous path by the laser beam for recording. As each successive area of the path is heated locally to the vicinity of its Curie point in the presence of a controlled magnetic field, a magneto-optic density is produced proportional to the amplitude of the controlled magnetic field. To play back the recorded signal, the intensity of the laser beam is reduced and a Faraday or Kerr effect analyzer is used, with a photodetector, as a transducer for producing an output signal.

  2. The Supervisory Control System for the HL-2A Neutral Beam Injector

    International Nuclear Information System (INIS)

    Supervisory control and protection system of the neutral beam injector (NBI) in the HL-2A tokamak is presented. The system is used for a safe coordination of all the main NBI subsystems. Because the system is based on computer networks with its transmission medium of optical fiber, its advantages in high operational stability, reliability, security and flexible functional expandability are clearly shown during the NBI commissioning and heating experiment in HL-2A.

  3. Robust Control Design for Vibration Isolation of an Electron Beam Projection Lithography System

    Science.gov (United States)

    Wang, Fu-Cheng; Hong, Min-Feng; Yen, Jia-Yush

    2010-06-01

    This paper describes vibration control for an electron beam projection lithography (EPL) system. Two kinds of disturbances should be considered for an EPL: load disturbances from the machine and ground disturbances from the environment. However, the suspension settings for insulating these two disturbances conflict with each other. Therefore, we propose a double-layer optical table and apply disturbance response decomposing (DRD) techniques to independently control the disturbances. We use a passive control structure to isolate the ground disturbances, and an active control structure to suppress load disturbances. In addition, symmetric transformation is applied to decouple a full optical table into bounce/pitch and roll/warp half-table models, which can be further decoupled into quarter-table models to simplify controller design. Finally, we apply robust control techniques to design active controllers. From both simulation and experimental results, the designed H∞ robust controllers are proven effective in reducing EPL system vibrations.

  4. TJ-II neutral beam injectors control and data acquisition system

    International Nuclear Information System (INIS)

    The Control and Data Acquisition System for the Neutral Beam Injectors of TJ-II are described in this paper. The DAQ and Control architecture is based on a distributed system including VME-OS9 real-time computers and personal computers (PCs) with Linux and Windows NT. One OS9-VME local computer located near each injector performs the timing, local signal processing, signal interlock, and operation of the injector mechanical and electrical components. A main OS9-VME interfaces and controls some peripheral systems, such as the high voltage power supplies, water cooling, safety and protection systems. Control is performed from the OS9-VME machines, in which the software elements are basically C/C++ programs performing real time processing and a web server enabling access to the HTML pages acting as user graphic interface

  5. Development of Distributed Control System for Neutral Beam Injector on EAST

    Science.gov (United States)

    Sheng, Peng; Hu, Chundong; Cui, Qinglong; Zhao, Yuanzhe; Zhang, Xiaodan; Zhang, Rui; Lin, Yulian; Yu, Shan; Gao, Yangyang

    2015-07-01

    A distributed control system of Neutral Beam Injector (NBI) on the Experimental Advanced Superconducting Tokamak (EAST-NBI) is briefly presented in this paper. The control system is developed in accordance with the experimental operational characteristics of the EAST-NBI. The NBI control system (NBICS), which is based on the computer network technologies and classified according to the control levels, consists of three levels: a remote monitoring layer, a server control layer, and a field control layer. The 3-layer architecture is capable of extending the system functions and upgrading devices. The timing system provides the reference clock of the synchronization and interlock for the EAST-NBI system. An interlock system ensures the safety of the experiment operators and field devices. Both of the ion sources of the beamline are designed to operate independently. This lays an important foundation for developing a control system for the second beamline on EAST. Experimental results demonstrate that the NBICS meets functional requirements of the EAST-NBI control, and makes experimental operations visual and automatic. supported by the National Magnetic Confinement Fusion Science Program of China (No. 2013GB101001)

  6. Use of object-oriented techniques in a beam-line control system

    International Nuclear Information System (INIS)

    The authors describe the use of object-oriented programming in the control and data-acquisition system for the upgraded CERN neutrino beam-line. C++ in conjunction with Posix threads running under Lynx-OS have been used in several front-end PCs. These communicate using Remote Procedure Calls over ethernet with a workstation running the commercial supervisory package, FactoryLink

  7. A LabVIEWTM-based scanning and control system for proton beam micromachining

    International Nuclear Information System (INIS)

    LabVIEWTM is steadily gaining in popularity as the programming language of choice for scientific data acquisition and control. This is due to the vast array of measurement instruments and data acquisition cards supported by the LabVIEWTM environment, and the relative ease with which advanced software can be programmed. Furthermore, virtual instruments that are designed for a given system can be easily ported to other LabVIEWTM platforms and hardware. This paper describes the new LabVIEWTM based scanning and control system developed specifically for proton beam micromachining (PBM) applications. The new system is capable of scanning figures at 16-bit resolution with improved sub-microsecond scan rates. Support for electrostatic beam blanking and external dose normalization using a TTL signal have been implemented. The new software incorporates a semi-automated dose calibration system, and a number of novel dose normalization methods. Limitations of the current beam scanning hardware are discussed in light of new results obtained from micromachining experiments performed in SU-8 photoresist

  8. A LabVIEW{sup TM}-based scanning and control system for proton beam micromachining

    Energy Technology Data Exchange (ETDEWEB)

    Bettiol, Andrew A. E-mail: phybaa@nus.edu.sg; Kan, J.A. van; Sum, T.C.; Watt, F

    2001-07-01

    LabVIEW{sup TM} is steadily gaining in popularity as the programming language of choice for scientific data acquisition and control. This is due to the vast array of measurement instruments and data acquisition cards supported by the LabVIEW{sup TM} environment, and the relative ease with which advanced software can be programmed. Furthermore, virtual instruments that are designed for a given system can be easily ported to other LabVIEW{sup TM} platforms and hardware. This paper describes the new LabVIEW{sup TM} based scanning and control system developed specifically for proton beam micromachining (PBM) applications. The new system is capable of scanning figures at 16-bit resolution with improved sub-microsecond scan rates. Support for electrostatic beam blanking and external dose normalization using a TTL signal have been implemented. The new software incorporates a semi-automated dose calibration system, and a number of novel dose normalization methods. Limitations of the current beam scanning hardware are discussed in light of new results obtained from micromachining experiments performed in SU-8 photoresist.

  9. The Application of Disturbance Response Decoupling to the Vibration Control of an Electron Beam Lithography System

    Science.gov (United States)

    Wang, Fu-Cheng; Tsao, Yu-Chia; Yen, Jia-Yush

    2009-06-01

    This paper demonstrates a method to control an electron beam lithography (EBL) system's vibrations with a newly developed technique called disturbance response decoupling (DRD). Resolution requirements make the vibration control of EBL systems increasingly important. Satisfying performance criteria requires considering two kinds of disturbances, load disturbances from the machine and ground disturbances from the environment, in EBL systems. Controlling lithography tools' vibrations has been studied for many years; however, designing controllers by traditional approaches can be very complicated because of these two types of disturbances' conflicting requirements. Therefore, DRD techniques were applied for this paper to deal independently with these performance requirements. The DRD control method was initially proposed in 2001 to address vehicle suspension control problems. This paper proposes a generalized and experimentally realized DRD control structure to suppress an EBL system's vibrations. The work was carried out in three parts. First, passive isolators were used to isolate ground disturbances. Second, active components were applied to improve the system's responses to load disturbances. Finally, the system was integrated to verify its overall performance. Simulations and experiments verify the proposed control strategies' effectiveness.

  10. Quality control beam of radiation through imaging system using a flat panel (ILD)

    International Nuclear Information System (INIS)

    The daily quality checks of the accelerator include, among others, checks of the daily calibration, symmetry and uniformity of the radiation beam. Usually verification systems daily are used for this purpose, which employ arrays of detectors of solid-state or ionization chambers. This paper intends to carry out the control of quality through the irradiation of a number of fields in the portal imaging system and its subsequent analysis in software's own creation, as well as the comparison of results with the daily verification system. (Author)

  11. RF Beam control system for the Brookhaven relativistic heavy ion collider, RHIC

    International Nuclear Information System (INIS)

    The Relativistic Heavy Ion Collider, RHIC, is two counter-rotating rings with six interaction points. The RF Beam Control system for each ring will control two 28 MHz cavities for acceleration, and five 197 MHz cavities for preserving the 5 ns bunch length during 10 hour beam stores. Digital technology is used extensively in: Direct Digital Synthesis of rf signals and Digital Signal Processing for, the realization of state-variable feedback loops, real-time calculation of rf frequency, and bunch-by-bunch phase measurement of the 120 bunches. DSP technology enables programming the parameters of the feedback loops in order to obtain closed-loop dynamics that are independent of synchrotron frequency

  12. Development of PLC based chiller control system for 3 MeV DC electron beam accelerator

    International Nuclear Information System (INIS)

    A 3 MeV DC electron beam accelerator is under development at Electron beam center, Kharghar, Navi Mumbai. The accelerator has various sections, where heat is generated during operation due to factors contributed by efficiency. The areas that produce heat such as beam dump, HV oscillator, scan horn region etc need to be cooled. A 5TR chiller unit has been installed in a room in the vicinity of the accelerator. Standard chiller unit available in the market do not provide a remote control interface, instead they provide on panel local controllers for the operation of the system. A PLC based interlock has been developed to control all the chiller components such as Cooling tower fan, cooling tower pump, ON/OFF operation of compressor etc. All the components used in chiller unit are interfaced to PLC besides temperature sensor. All machine safety interlock have been introduced by using suitable hardware such as antifreeze coil used to trip compressor in case of control failure may make the ice of water being cooled. The operating point of the chiller has been set to provide water 22-24 degree C. The PLC has been programmed using ladder logic programming method. The system is fully automatic. The system can be operated by setting the set temperature say 22 degree C and temperature hysteresis say 2 degree C. Pressing start button operates different units of the system automatically. Its starts the compressor when the water temperature is 22+2 degree C and stops the compressor when temp reaches at 22 degree C. Any unexpected failure such as 3Phase sequence change/phase failure, over load relay trip, excess temp are indicated by a hooter sound along with fault display on the HMI. A touch screen panel has been provided for human machine interface. This development of control system for chiller sub-system of accelerator has helped us in bringing the chiller unit control from the control room using Ethernet link using Modbus TCP-IP. The implementation of PLC controlled chiller

  13. Toward automated beam optics control

    International Nuclear Information System (INIS)

    We have begun a program aiming toward automatic control of charged-particle beam optics using artificial intelligence programming techniques. In developing our prototype, we are working with LISP machines and the KEE expert system shell. Our first goal was to develop a ''mouseable'' representation of a typical beam line. This responds actively to changes entered from the mouse or keyboard, giving an updated display of the beam line itself, its optical properties, and the instrumentation and control devices as seen by the operater. We have incorporated TRANSPORT, written in Fortran but running as a callable procedure in the LISP environment, for simulation of the beam-line optics. This paper describes the experience gained in meeting our first goal and discusses plans to extend the work so that it is usable, in realtime, on an operating beam line. 11 refs

  14. Modeling and simulation of control system for electron beam machine (EBM) using programmable automation controller (PAC)

    International Nuclear Information System (INIS)

    An EBM electronic model is designed to simulate the control system of the Nissin EBM, which is located at Block 43, MINT complex of Jalan Dengkil with maximum output of 3 MeV, 30 mA using a Programmable Automation Controllers (PAC). This model operates likes a real EBM system where all the start-up, interlocking and stopping procedures are fully followed. It also involves formulating the mathematical models to relate certain output with the input parameters using data from actual operation on EB machine. The simulation involves a set of PAC system consisting of the digital and analogue input/output modules. The program code is written using Labview software (real-time version) on a PC and then downloaded into the PAC stand-alone memory. All the 23 interlocking signals required by the EB machine are manually controlled by mechanical switches and represented by LEDs. The EB parameters are manually controlled by potentiometers and displayed on analogue and digital meters. All these signals are then interfaced to the PC via a wifi wireless communication built-in at the PAC controller. The program is developed in accordance to the specifications and requirement of the original real EB system and displays them on the panel of the model and also on the PC monitor. All possible chances from human errors, hardware and software malfunctions, including the worst-case conditions will be tested, evaluated and modified. We hope that the performance of our model complies the requirements of operating the EB machine. It also hopes that this electronic model can replace the original PC interfacing being utilized in the Nissin EBM in the near future. The system can also be used to study the fault tolerance analysis and automatic re-configuration for advanced control of the EB system. (Author)

  15. Artificial intelligence research in particle accelerator control systems for beam line tuning

    Energy Technology Data Exchange (ETDEWEB)

    Pieck, Martin [Los Alamos National Laboratory

    2008-01-01

    Tuning particle accelerators is time consuming and expensive, with a number of inherently non-linear interactions between system components. Conventional control methods have not been successful in this domain and the result is constant and expensive monitoring of the systems by human operators. This is particularly true for the start-up and conditioning phase after a maintenance period or an unexpected fault. In turn, this often requires a step-by-step restart of the accelerator. Surprisingly few attempts have been made to apply intelligent accelerator control techniques to help with beam tuning, fault detection, and fault recovery problems. The reason for that might be that accelerator facilities are rare and difficult to understand systems that require detailed expert knowledge about the underlying physics as well as months if not years of experience to understand the relationship between individual components, particularly if they are geographically disjoint. This paper will give an overview about the research effort in the accelerator community that has been dedicated to the use of artificial intelligence methods for accelerator beam line tuning.

  16. The EPICS-based remote control system for muon beam line devices at J-PARC MUSE

    Energy Technology Data Exchange (ETDEWEB)

    Ito, T U; Higemoto, W [Advanced Science Research Center, Japan Atomic Energy Agency, Tokai, Ibaraki 319-1195 (Japan); Nakahara, K; Fujimori, H; Kobayashi, Y; Miyake, Y [Muon Science Laboratory, High Energy Accelerator Research Organization (KEK), Tsukuba, Ibaraki 305-0801 (Japan); Kawase, M, E-mail: ito.takashi15@jaea.go.j [J-PARC Center, Japan Atomic Energy Agency, Tokai, Ibaraki 319-1195 (Japan)

    2010-04-01

    The remote control system for muon beam line devices of J-PARC MUSE has been developed with the Experimental Physics and Industrial Control System (EPICS). The EPICS input/output controller was installed in standard Linux PCs for slow control of the devices. Power supplies for 21 magnetic elements and four slit controllers for the decay-surface muon beam line in the Materials and Life Science Experimental Facility are now accessible via Ethernet from a graphical user interface which has been composed using the Motif Editor and Display Manger.

  17. The EPICS-based remote control system for muon beam line devices at J-PARC MUSE

    International Nuclear Information System (INIS)

    The remote control system for muon beam line devices of J-PARC MUSE has been developed with the Experimental Physics and Industrial Control System (EPICS). The EPICS input/output controller was installed in standard Linux PCs for slow control of the devices. Power supplies for 21 magnetic elements and four slit controllers for the decay-surface muon beam line in the Materials and Life Science Experimental Facility are now accessible via Ethernet from a graphical user interface which has been composed using the Motif Editor and Display Manger.

  18. Real-time depth monitoring and control of laser machining through scanning beam delivery system

    Science.gov (United States)

    Ji, Yang; Grindal, Alexander W.; Webster, Paul J. L.; Fraser, James M.

    2015-04-01

    Scanning optics enable many laser applications in manufacturing because their low inertia allows rapid movement of the process beam across the sample. We describe our method of inline coherent imaging for real-time (up to 230 kHz) micron-scale (7-8 µm axial resolution) tracking and control of laser machining depth through a scanning galvo-telecentric beam delivery system. For 1 cm trench etching in stainless steel, we collect high speed intrapulse and interpulse morphology which is useful for further understanding underlying mechanisms or comparison with numerical models. We also collect overall sweep-to-sweep depth penetration which can be used for feedback depth control. For trench etching in silicon, we show the relationship of etch rate with average power and scan speed by computer processing of depth information without destructive sample post-processing. We also achieve three-dimensional infrared continuous wave (modulated) laser machining of a 3.96 × 3.96 × 0.5 mm3 (length × width × maximum depth) pattern on steel with depth feedback. To the best of our knowledge, this is the first successful demonstration of direct real-time depth monitoring and control of laser machining with scanning optics.

  19. Real-time depth monitoring and control of laser machining through scanning beam delivery system

    International Nuclear Information System (INIS)

    Scanning optics enable many laser applications in manufacturing because their low inertia allows rapid movement of the process beam across the sample. We describe our method of inline coherent imaging for real-time (up to 230 kHz) micron-scale (7–8 µm axial resolution) tracking and control of laser machining depth through a scanning galvo-telecentric beam delivery system. For 1 cm trench etching in stainless steel, we collect high speed intrapulse and interpulse morphology which is useful for further understanding underlying mechanisms or comparison with numerical models. We also collect overall sweep-to-sweep depth penetration which can be used for feedback depth control. For trench etching in silicon, we show the relationship of etch rate with average power and scan speed by computer processing of depth information without destructive sample post-processing. We also achieve three-dimensional infrared continuous wave (modulated) laser machining of a 3.96 × 3.96 × 0.5 mm3 (length × width × maximum depth) pattern on steel with depth feedback. To the best of our knowledge, this is the first successful demonstration of direct real-time depth monitoring and control of laser machining with scanning optics. (paper)

  20. Electron beam focusing system

    Energy Technology Data Exchange (ETDEWEB)

    Dikansky, N.; Nagaitsev, S.; Parkhomchuk, V.

    1997-09-01

    The high energy electron cooling requires a very cold electron beam. Thus, the electron beam focusing system is very important for the performance of electron cooling. A system with and without longitudinal magnetic field is presented for discussion. Interaction of electron beam with the vacuum chamber as well as with the background ions and stored antiprotons can cause the coherent electron beam instabilities. Focusing system requirements needed to suppress these instabilities are presented.

  1. Feedback control and beam diagnostic algorithms for a multiprocessor DSP system

    International Nuclear Information System (INIS)

    The multibunch longitudinal feedback system developed for use by PEP-II, ALS, and DAΦNE uses a parallel array of digital signal processors (DSPs) to calculate the feedback signals from measurements of beam motion. The system is designed with general-purpose programmable elements which allow many feedback operating modes as well as system diagnostics, calibrations, and accelerator measurements. The overall signal processing architecture of the system is illustrated. The real-time DSP algorithms and off-line postprocessing tools are presented. The problems in managing 320k samples of data collected in one beam transient measurement are discussed and our solutions are presented. Example software structures are presented showing the beam feedback process, techniques for modal analysis of beam motion (used to quantify growth and damping rates of instabilities), and diagnostic functions (such as timing adjustment of beam pick-up and kicker components). These operating techniques are illustrated with example results obtained from the system installed at the Advanced Light Source at LBL. copyright 1997 American Institute of Physics

  2. Depth-controlled Bessel beams

    CERN Document Server

    Müller, Angelina; Wallrabe, Ulrike

    2016-01-01

    We present a ring aperture with independently switchable segments for the three-dimensional control of quasi propagation invariant beams. We demonstrate that our liquid crystal design concept preserves coherence and generates the Bessel beam structure.

  3. Beam alignment system

    International Nuclear Information System (INIS)

    A patent is claimed for the invention of a beam alignment system. The aim of the invention is the obtention of an accurate monitoring of the beam position and direction. It is of great interest in the nuclear industry. The invention can be applied in an infrared laser beam for welding operations. An auxiliar radiation source is incorporated to the device. The system's configuration allows a simultaneous and separated utilisation of two beams. The description and the design of the proposed system are provided

  4. Arc and filament heater current control system for 5 MW ion source of neutral beam injector for SST1

    International Nuclear Information System (INIS)

    This paper presents control system used in managing power system deployed on 1.7 MW neutral beam injector at 80 kV. Power system consists of 24 arc discharge current power supplies (120 V, 80 A, DC), 8 filament heater power supplies (200V, 10 A, 400 Hz, AC) and one highly regulated high voltage power supply (80 kV, 60ADC)

  5. MPS beam control software architecture

    International Nuclear Information System (INIS)

    The new Machine Protection System (MPS) now being tested at SLAC has a beam control subsystem resident in processors located close to the beam monitoring devices within the machine. There are two types of beam control micros: Algorithm Processors (AP's) which collect and evaluate data from monitoring devices, and a Supervisor (SUPE) which collects and evaluates data from all the AP's. The SUPE also receives the global machine beamcode indicating beam presence, and passes it on to the AP's. The SUPE receives the beamcode pattern from the Master Pattern Generator (MPG) via a shared-memory communication link. MIL-1553 serial communication is used between the SUPE and the AP's, and between the AP's and the monitoring devices. Multitasking software is used to allow high priority handling of data evaluation and low priority handling of host/user interfacing and event reporting. Pipelining of data between acquisition and evaluation and reporting is used to accommodate the processing capacity, while still supporting full processing at the 36OHz broadcast rate of the beamcode pattern

  6. MPS beam control software architecture

    International Nuclear Information System (INIS)

    The new Machine Protection System (MPS) now being tested at SLAC has a beam control subsystem resident in processors located close to the beam monitoring devices within the machine. There are two types of beam control micros: Algorithm Processors (AP's) which collect and evaluate data from monitoring devices, and a Supervisor (SUPE) which collects and evaluates data from all the AP's. The SUPE also receives the global machine beamcode indicating beam presence, and passes it on to the AP's. The SUPE receives the beamcode pattern from the Master Pattern Generator (MPG) via a shared-memory communication link. MIL-1553 serial communication is used between the SUPE and the AP's, and between the AP's and the monitoring devices. Multitasking software is used to allow high priority handling of data evaluation and low priority handling of host/user interfacing and event reporting. Pipelining of data between acquisition and evaluation and reporting is used to accomodate the processing capacity, while still supporting full processing at the 360Hz broadcast rate of the beamcode pattern

  7. Cyclotron radiation beam control

    International Nuclear Information System (INIS)

    This patent application describes an apparatus for attenuating a beam of particulate radiation comprising a series of modules, each module being constituted by a sphere having a passage, a cupola covering said sphere and a base supporting said sphere, and means for causing movement of the spheres for aligning said passages with an axis of a beam line and arranging said passages out of alignment so as to attenuate the beam. (author)

  8. Beam control and Dosimetry in Proton Therapy

    International Nuclear Information System (INIS)

    This thesis deals with beam control devices for scanned proton beams. The IBA society (Ion Beam Applications) has developed a new dynamic beam delivery system called Pencil Beam Scanning. IBA needed a monitor unit to equip its proton beam lines dedicated to the PBS system and called upon the medical applications group of the Laboratoire de Physique Corpusculaire de Caen. In 2008, this group realized, in collaboration with IBA, an ionization chamber monitor IC2/3 for the IBA dedicated PBS nozzle. This device verifies the agreement between planned and delivered particular fluence. The first part of this thesis focused on the characterization of this monitor unit. Proton beams of different clinical energies, positions and dose rates were used to check the specifications requested by IBA. After the introduction about the Proton Therapy, the validation step of IC2/3 is exposed. Information provided by IC2/3 makes it possible beam control in terms of fluence but does not ensure quality control in terms of spatial dose distribution. The second part of the work was devoted to the conception of a beam control device for scanned proton beams. Called Compass PT, it will allow a reconstruction of the spatial dose distribution delivered to the patient. The specifications definition and the conception studies are presented in this thesis. All this work has led to recommendations for the realization of this device and new research prospects. (author)

  9. Use of the TACL [Thaumaturgic Automated Control Logic] system at CEBAF [Continuous Electron Beam Accelerator Facility] for control of the Cryogenic Test Facility

    International Nuclear Information System (INIS)

    A logic-based control software system, called Thaumaturgic Automated Control Logic (TACL), is under development at the Continuous Electron Beam Accelerator Facility in Newport News, VA. The first version of the software was placed in service in November, 1987 for control of cryogenics during the first superconducting RF cavity tests at CEBAF. In August, 1988 the control system was installed at the Cryogenic Test Facility (CTF) at CEBAF. CTF generated liquid helium in September, 1988 and is now in full operation for the current round of cavity tests. TACL is providing a powerful and flexible controls environment for the operation of CTF. 3 refs

  10. A wireless control system for the HTS-ECRIS, PKDELIS and low energy beam transport

    International Nuclear Information System (INIS)

    The 18 GHz High Temperature Superconducting ECR ion source at the Inter University Accelerator Centre (IUAC), New Delhi is the first High Temperature ECR Ion source designed for operation on a 400 kV high voltage platform as part of the High Current Injector development programme. For automation of source operation and control of source parameters, a wireless control system has been developed. Connection to the Ethernet based central control system has been provided. (author)

  11. Programmable logic controller system in neutral beam injector's ion source test stand

    International Nuclear Information System (INIS)

    Due to the real-time monitoring requirement of field devices in EAST-NBI ion source test stand, this paper introduces a programmable logic controller (PLC) system based on Profibus protocol. The hardware configuration of PLC system can be determined according to the requirement of test stand, a Profibus-DP network with single-master workstation make a distributed I/O system. The PLC system can monitor the field devices' status in real time, exchange data with NBI control system and instruct field devices work stably. In addition, full graphical user interface can realize the visualization of system operation, data storage and display in real-time, which will provide a basis for experimental analysis for physical operator. The whole PLC system is reliable,reproducible, well compatible and scalable, which can be used to monitor and control the field devices in EAST-NBI test stand. (authors)

  12. Controlling Second Harmonic Efficiency of Laser Beam Interactions

    Science.gov (United States)

    Barnes, Norman P. (Inventor); Walsh, Brian M. (Inventor); Reichle, Donald J. (Inventor)

    2011-01-01

    A method is provided for controlling second harmonic efficiency of laser beam interactions. A laser system generates two laser beams (e.g., a laser beam with two polarizations) for incidence on a nonlinear crystal having a preferred direction of propagation. Prior to incidence on the crystal, the beams are optically processed based on the crystal's beam separation characteristics to thereby control a position in the crystal along the preferred direction of propagation at which the beams interact.

  13. A beam diagnostic and control module

    International Nuclear Information System (INIS)

    A Beam Diagnostic and Control Module based on MSC1210 mixed-signal processor was developed in IMP. It used OPA128, an ultra-low bias current monolithic operational amplifier, as preamplifier, a high accuracy 24-bit ADC on MSC1210 for weak beam current read out. It also has digital I/O function and relays for beam diagnostic components control. It is a stand-alone meter, can communicate with computer through RS-232 or RS-485 communication ports. The display panel is an 8-digit LCD. The modules are now used in HIRFL-CSR beam diagnostic and control system. It plays an important role in whole HIRFL-CSR control system. (author)

  14. Rf beam control for the AGS Booster

    International Nuclear Information System (INIS)

    RF beam control systems for hadron synchrotrons have evolved over the past three decades into an essentially standard design. The key difference between hadron and lepton machines is the absence of radiation damping and existence of significant frequency variation in the case of hadrons. Although the motion of the hadron in the potential well of the rf wave is inherently stable it is not strongly damped. Damping must be provided by electronic feedback through the accelerating system. This feedback is typically called the phase loop. The technology of the rf beam control system for the AGS Booster synchrotron is described. First, the overall philosophy of the design is explained in terms of a conventional servo system that regulates the beam horizontal position in the vacuum chamber. The concept of beam transfer functions is fundamental to the mathematics of the design process and is reviewed. The beam transfer functions required for this design are derived from first principles. An overview of the beam signal pick-ups and high level rf equipment is given. The major subsystems, the frequency program, the heterodyne system, and beam feedback loops, are described in detail. Beyond accelerating the beam, the rf system must also synchronize the bunches in the Booster to the buckets in the AGS before transfer. The technical challenge in this process is heightened by the need to accomplish synchronization while the frequency is still changing. Details of the synchronization system are given. This report is intended to serve two purposes. One is to document the hardware and performance of the systems that have been built. The other is to serve as a tutorial vehicle from which the non-expert can not only learn the details of this system but also learn the principles of beam control that have led to the particular design choices made

  15. Pre Design of Beam Parameter Control System for Electron Beam Machine (EBM) 350 keV/10 mA in the Center for Accelerator and Material Process Technology - BATAN Yogyakarta

    International Nuclear Information System (INIS)

    Pre design of beam parameter control system for Electron Beam Machine (EBM) 350 keV/10 mA had an objective to find a control system algorithm for EBM in The Center For Accelerator and Material Process Technology (Pusat Teknologi dan Proses Bahan/PTAPB) - BATAN Yogyakarta. The design was based on the beam parameter model of EBM. The model shown a relationship between the dose parameter setting and the beam energy setting which it was being a problem in setting the beam parameters.The control system algorithm was found by getting compensator equations from the beam parameter model of EBM. The equations would omit the relation between the radiation dose parameter and beam energy parameter, so that the parameters could be adjusted easily. The result of the control system algorithm examine based on simulation shown that the setting of beam parameter value could be done by giving the accelerating voltage value and the filament current value as the operator had determined the value. The value of radiation dose and beam energy would be adjusted as its function of the filament current value and the accelerating voltage value. (author)

  16. ITER Neutral Beam Injection System

    International Nuclear Information System (INIS)

    A Japanese design proposal of the ITER Neutral Beam Injection System (NBS) which is consistent with the ITER common design requirements is described. The injection system is required to deliver a neutral deuterium beam of 75MW at 1.3MeV to the reactor plasma and utilized not only for plasma heating but also for current drive and current profile control. The injection system is composed of 9 modules, each of which is designed so as to inject a 1.3MeV, 10MW neutral beam. The most important point in the design is that the injection system is based on the utilization of a cesium-seeded volume negative ion source which can produce an intense negative ion beam with high current density at a low source operating pressure. The design value of the source is based on the experimental values achieved at JAERI. The utilization of the cesium-seeded volume source is essential to the design of an efficient and compact neutral beam injection system which satisfies the ITER common design requirements. The critical components to realize this design are the 1.3MeV, 17A electrostatic accelerator and the high voltage DC acceleration power supply, whose performances must be demonstrated prior to the construction of ITER NBI system. (author)

  17. LHC beam instrumentation detectors and acquisition systems

    International Nuclear Information System (INIS)

    An overview of some of the detectors and acquisition systems being developed for measuring and controlling beam parameters in the LHC. The two largest systems concern the measurement of beam position, with over 1000 monitors, and beam loss, with over 3000 monitors. For the beam position system a novel wide band time normaliser has been developed to allow bunch-by-bunch 40MHz acquisitions with a dynamic range greater than 30dB and an overall linearity of better than 1%. Also mentioned will be the acquisition system for the fast beam current transformers and the development of CdTe detectors for luminosity monitoring. [author

  18. ITER neutral beam system

    International Nuclear Information System (INIS)

    The Neutral Beam (NB) system for the International Thermonuclear Experimental Reactor (ITER) has reached a high degree of integration with the tokamak and with the rest of the plant. Operational requirements and maintainability have been considered in the design. The paper considers the integration with the tokamak, discusses design improvements which appear necessary and finally notes R and D progress in key areas. (author)

  19. Electron beam processing system

    International Nuclear Information System (INIS)

    Electron beam Processing Systems (EPS) are used as useful and powerful tools in many industrial application fields such as the production of cross-linked wire, rubber tire, heat shrinkable film and tubing, curing, degradation of polymers, sterilization and environmental application. In this paper, the feature and application fields, the selection of machine ratings and safety measures of EPS will be described. (author)

  20. Neutral beam data systems at ORNL

    International Nuclear Information System (INIS)

    A control system for neutral injection beam lines has been designed, implemented, and used with much success. Despite the problems with very high power levels this system is very successful in relieving the operators burdens of slow conditioning, data recording, and mode switching. The use of computer control with multiple beam lines now appears very promising

  1. Control and data acquisition system for Beam Line C and HRS

    International Nuclear Information System (INIS)

    The High Resolution Spectrometer (HRS) at LAMPF is a multimillion dollar facility intended for the study of proton induced reactions and scattering with 100 to 800 MeV protons. It will be used by research scientists from universities and other national laboratories throughout the United States. The design resolution of +-1.5:10-5 is better than any similar system ever attempted in this energy range. To obtain this quality as well as fully realize the research potential of the facility, a rather sophisticated computer control and data acquisition system is required. The facility, based on a general multiuser, multitask, multiprocessor system, is described

  2. WELD FORMATION CONTROL AT ELECTRON BEAM WELDING WITH BEAM OSCILLATIONS

    OpenAIRE

    Trushnikov, Dmitriy; Koleva, Elena; Mladenov, Georgy; Shcherbakov, A.

    2014-01-01

    Electron beam welding is used extensively to produce essential machine parts. The control of the basic beam parameters beam power or beam current at constant accelerating voltage, welding speed, current of focusing lens and distance between electron gun and welded sample surface is not enough to obtain at most of the regimes sound welds. Control of the focus position using analysis of the high frequency component of the current, collected by plasma, at periodic interactions on the beam (the o...

  3. Upgrade of beam steering system components and controls for the NSLS storage rings

    International Nuclear Information System (INIS)

    The installation of the new insertion devices and new experiments on the NSLS storage rings has increased the demand for better stability of the electron orbit. This, in turn, increased the demand for better stability and resolution as well as larger bandwidth of the orbit correction system. All of the orbit correcting dipoles now have new low-hysteresis laminated steel cores. The magnets are excited by commercial wide-band (1 kHz) current regulated power supplies. The input circuits of the new power supplies permit a summation of analog inputs from orbit stabilization systems with set-point inputs digitally controlled by the operator. This paper describes the design of the new system and summarizes its present performance. 2 refs., 8 figs., 1 tab

  4. Supervisory control software for MFTF neutral beams

    International Nuclear Information System (INIS)

    We describe the software structures that control the operation of MFTF Sustaining Neutral Beam Power Supplies (SNBPS). These components of the Supervisory Control and Diagnostics System (SCDS) comprise ten distinct tasks that exist in the SCDS system environment. The codes total about 16,000 lines of commented Pascal code and occupy 240 kbytes of memory. The controls have been running since March 1981, and at this writing are being integrated to the Local Control System and to the power supply Pulse Power Module Controller

  5. Quality control of JEOL JBX-9500FSZ e-beam lithography system in a multi-user laboratory

    DEFF Research Database (Denmark)

    Greibe, Tine; Anhøj, Thomas Aarøe; Johansen, Leif; Han, Anpan

    2016-01-01

    designed quality control procedure characterized using a scanning electron microscope. We inspect position accuracy, dynamic focus, and dynamic astigmatism, as well as single and multi-pixel lines in thin resist. Beam shape quality is inspected in the corners of the writing field at 6 different beam...

  6. Method and apparatus for laser-controlled proton beam radiology

    Science.gov (United States)

    Johnstone, Carol J.

    1998-01-01

    A proton beam radiology system provides cancer treatment and proton radiography. The system includes an accelerator for producing an H.sup.- beam and a laser source for generating a laser beam. A photodetachment module is located proximate the periphery of the accelerator. The photodetachment module combines the H.sup.- beam and laser beam to produce a neutral beam therefrom within a subsection of the H.sup.- beam. The photodetachment module emits the neutral beam along a trajectory defined by the laser beam. The photodetachment module includes a stripping foil which forms a proton beam from the neutral beam. The proton beam is delivered to a conveyance segment which transports the proton beam to a patient treatment station. The photodetachment module further includes a laser scanner which moves the laser beam along a path transverse to the cross-section of the H.sup.- beam in order to form the neutral beam in subsections of the H.sup.- beam. As the scanning laser moves across the H.sup.- beam, it similarly varies the trajectory of the proton beam emitted from the photodetachment module and in turn varies the target location of the proton beam upon the patient. Intensity modulation of the proton beam can also be achieved by controlling the output of the laser.

  7. Design for controllable optofluidic beam splitter

    Science.gov (United States)

    Tang, Xionggui; Liang, Shan; Li, Rujian

    2016-01-01

    A novel configuration for controllable optofluidic beam splitter is proposed, which consists of the asymmetric Y-branch waveguide and the microfluidic channel filled with fluid mixture. The beam propagation method (BPM) is employed to numerically investigate the optical performance of device in our layout. The simulated results demonstrate that arbitrary splitting ratio and low optical loss for both TE and TM mode can be easily achieved, with a low dependence of wavelength and polarization. Particularly, the optofluidic beam splitter has advantages such as compact structure and large fabrication tolerance. The proposed device provides a new way to manipulate the optical power splitting, and has wide potential applications in integrated optofluidic system.

  8. Control And Transport Of Intense Electron Beams

    CERN Document Server

    Li, H

    2004-01-01

    The transport of intense beams for advanced accelerator applications with high-intensity beams such as heavy-ion inertial fusion, spallation neutron sources, and intense light sources requires tight control of beam characteristics over long distances. The University of Maryland Electron Ring (UMER), which uses low energy, high current electron beams to model the transport physics of intense space-charge-dominated beams, employs real-time beam characterization and control in order to optimize beam quality throughout the strong focusing lattice. We describe in this dissertation the main beam control techniques used in UMER, which include optimal beam steering by quadrupole scans, beam rotation correction using a skew corrector, rms envelope matching and optimization, empirical envelope matching, beam injection, and phase space reconstruction using a tomographic method. Using these control techniques, we achieved the design goals for UMER. The procedure is not only indispensable for optimum beam transport over l...

  9. BEAM CONTAINMENT SYSTEM FOR NSLS-II

    International Nuclear Information System (INIS)

    The shielding design for the NSLS-II will provide adequate protection for the full injected beam loss in two periods of the ring around the injection point, but the remainder of the ring is shielded for lower losses of (le) 10% full beam. This will require a system to insure that beam losses don't exceed these levels for a period of time that could cause excessive radiation levels outside the shield walls. This beam containment system will measure, provide a level of control and alarm indication of the beam power losses along the beam path from the source (e-gun, linac) thru the injection system and the storage ring. This system will consist of collimators that will provide limits to (and potentially to measure) the beam miss-steering and control the loss points of the charge and monitors that will measure the average beam current losses along the beam path and alarm when this beam power loss exceeds the level set by the shielding specifications. This will require some new ideas in beam loss detection capability and collimation. The initial planning and R and D program will be presented.

  10. Design of DC Motor Driver as a Control System Actuator for Electron Source in Electron Beam Machine

    International Nuclear Information System (INIS)

    A DC motor driver has been contracted using chopper DC circuit. The DC motor driver consists of an inverting amplifier, a comparator, and a DC chopper unit. The DC chopper circuit is based on H hybrid circuit, so that the polarization and angular velocity of DC motor can be regulated similar with the polarization and value of input signal. The result showed, that the DC motor driver circuit can be used as actuator on the electron source of electron beam machine. The maximum (duty cycle value = 1/2) angular velocity has same value for 10-1 - 10-2 Hertz oscillator frequency range. The increase of angular velocity will be proportional to the oscillator frequency at the constant duty cycle. If this characteristic is related with respond time of the control system, so the control system respond time is dependence on oscillator frequency being used. The use of control system with PC can be realized, because the input signal use low voltage, where the measurement shows that it has 3 - 10 Volt voltage range. (author)

  11. Automatic control and monitoring of the MIT fission converter beam

    International Nuclear Information System (INIS)

    An automated control and monitoring system for the new MIT high intensity epithermal neutron irradiation facility has been designed and constructed. The neutron beam is monitored with fission counters located at the periphery of the beam near the patient position. Control of the beam is accomplished with redundant Programmable Logic Controllers (PLCs). These industrial controllers open and close the three shutters of the Fission Converter Beam. The control system uses a series of robust components to assure that the prescribed fluence is delivered. This paper discusses the design and implementation of this system. (author)

  12. A PC-PCL-based control system for the high-voltage pulsed-power operation of the Intense Diagnostic Neutral Beam (IDNB) Experiment

    International Nuclear Information System (INIS)

    A stand-alone, semiautomated control system for the high-voltage pulsed-power energy sources on the Intense Diagnostic Neutral Beam Experiment at Los Alamos National Laboratory using personal computer (PC) and programmable logic controller (PLC) technology has been developed and implemented. The control system, consisting of a PC with the graphic operator interface, the network connecting the PC to the PLC, the PLC, the PLC I/O modules, fiber-optic interfaces and software, is described

  13. LHC beam stability and feedback control

    Energy Technology Data Exchange (ETDEWEB)

    Steinhagen, Ralph

    2007-07-20

    This report presents the stability and the control of the Large Hadron Collider's (LHC) two beam orbits and their particle momenta using beam-based feedback systems. The aim of this report is to contribute to a safe and reliable LHC commissioning and machine operation. The first part of the analysis gives an estimate of the expected sources of orbit and energy perturbations that can be grouped into environmental sources, machine-inherent sources and machine element failures: the slowest perturbation due to ground motion, tides, temperature fluctuations of the tunnel and other environmental influences are described in this report by a propagation model that is both qualitatively and quantitatively supported by geophone and beam motion measurements at LEP and other CERN accelerators. The second part of this analysis deals with the control of the two LHC beams' orbit and energy through automated feedback systems. Based on the reading of the more than 1056 beam position monitors (BPMs) that are distributed over the machine, a central global feedback controller calculates new deflection strengths for the more than 1060 orbit corrector magnets (CODs) that are suitable to correct the orbit and momentum around their references. this report provides an analysis of the BPMs and CODs involved in the orbit and energy feedback. The BPMs are based on a wide-band time normaliser circuit that converts the transverse beam position reading of each individual particle bunch into two laser pulses that are separated by a time delay and transmitted through optical fibres to an acquisition card that converts the delay signals into a digital position. A simple error model has been tested and compared to the measurement accuracy of LHC type BPMs, obtained through beam-based measurements in the SPS. The average beam position is controlled through 1060 superconducting and individually powered corrector dipole magnets. The proposed correction in 'time-domain' consists of a

  14. LHC beam stability and feedback control

    International Nuclear Information System (INIS)

    This report presents the stability and the control of the Large Hadron Collider's (LHC) two beam orbits and their particle momenta using beam-based feedback systems. The aim of this report is to contribute to a safe and reliable LHC commissioning and machine operation. The first part of the analysis gives an estimate of the expected sources of orbit and energy perturbations that can be grouped into environmental sources, machine-inherent sources and machine element failures: the slowest perturbation due to ground motion, tides, temperature fluctuations of the tunnel and other environmental influences are described in this report by a propagation model that is both qualitatively and quantitatively supported by geophone and beam motion measurements at LEP and other CERN accelerators. The second part of this analysis deals with the control of the two LHC beams' orbit and energy through automated feedback systems. Based on the reading of the more than 1056 beam position monitors (BPMs) that are distributed over the machine, a central global feedback controller calculates new deflection strengths for the more than 1060 orbit corrector magnets (CODs) that are suitable to correct the orbit and momentum around their references. this report provides an analysis of the BPMs and CODs involved in the orbit and energy feedback. The BPMs are based on a wide-band time normaliser circuit that converts the transverse beam position reading of each individual particle bunch into two laser pulses that are separated by a time delay and transmitted through optical fibres to an acquisition card that converts the delay signals into a digital position. A simple error model has been tested and compared to the measurement accuracy of LHC type BPMs, obtained through beam-based measurements in the SPS. The average beam position is controlled through 1060 superconducting and individually powered corrector dipole magnets. The proposed correction in 'time-domain' consists of a proportional

  15. Self-Tuning Active Vibration Control of Flexible Beam Structures

    OpenAIRE

    M.O. Tokhi; Hossain, M A

    1994-01-01

    This paper presents the design and performance evaluation of an adaptive active control mechanism for vibration suppression in flexible beam structures. A cantilever beam system in transverse vibration is considered. First order control finite difference methods are used to study the behaviour of the beam and develop a suitable test and verification platform. An active vibration control algorithm is developed within an adaptive control framework for broadband cancellation of vibration along t...

  16. Beam screen cryogenic control improvements for the LHC run 2

    CERN Document Server

    Bradu, Benjamin; Blanco Vinuela, Enrique; Ferlin, Gerard; Tovar-Gonzalez, Antonio

    2016-01-01

    This paper presents the improvements performed on the cryogenic control system for the LHC beam screens. The regulation objective is to maintain an acceptable temperature range around 20 K that ensures a good LHC beam vacuum and that limits cryogenic heat loads. In total, there are 485 regulation loops around the 27 km of the LHC machine affected by these beam disturbances. Due to the increase of the LHC performance during the run 2, standard PID controllers manage with difficulties the temperature transients of the beam screens. Several alternative control techniques have been studied and validated using dynamic simulation and then deployed on the LHC cryogenic control system in 2015. The main contribution is the addition of a feed-forward control in order to compensate the beam effects on the beam screen temperature based on the main beam parameters of the machine in real time.

  17. Control of beam halo-chaos using fuzzy logic controller

    International Nuclear Information System (INIS)

    Considering the ion beam with initial K-V distribution in the periodic focusing magnetic filed channels (PFCs) as a typical sample, a fuzzy control method for control- ling beam halo-chaos was studied. A fuzzy proportional controller, using output of fuzzy inference as a control factor, was presented for adjusting exterior focusing magnetic field. The stability of controlled system was proved by fuzzy phase plane analysis. The simulation results demonstrate that the chaotic radius of envelope can be controlled to the matched radius via controlling magnetic field. This method was also applied to the multi-particle model. Under the control condition, the beam halos and its regeneration can be eliminated effectively, and that both the compactness and the uniformity of ion beam are improved evidently. Since the exterior magnetic field can be rather easily adjusted by proportional control and the fuzzy logic controller is independent to the mathematical model, this method has adaptive ability and is easily realized in experiment. The research offers a valuable reference for the design of the PFCs in the high- current linear ion accelerators. (authors)

  18. Beam alignment system for laser welding system

    International Nuclear Information System (INIS)

    The patent describes a beam alignment system for laser welding work pieces, such as fuel rod grids for nuclear fuel assemblies. The apparatus for performing various laser-machining comprises a beam alignment system including alignment target means, as well as means for emitting, directing and focusing the laser beam. (U.K.)

  19. Control and measurement of ion-energy distributions in a beam-plasma system

    Science.gov (United States)

    Zi-An, Wei; Jin-Xiu, Ma; CAS Key Laboratory of Geospace Environment; Department of Modern Physics Team

    2015-11-01

    A double plasma device is divided by two grids separating source and experimental chambers. Ions are accelerated by the voltage drop between two grids. To study the ion-energy in the experimental region, the ion distribution function (IDF) was probed using a retarding field energy analyzer, also the correlation between the IDF and discharge parameters was studied. It is shown that the IDF in the experimental region exhibits a double-peak structure containing a background and a high-energy streaming-ion groups. The proportion of the ion groups can be controlled by the filament current. Supported by the National Natural Science Foundation of China (Grant Nos. 11175177 and J1103207).

  20. Advanced Light Source beam diagnostics systems

    International Nuclear Information System (INIS)

    The Advanced Light Source (ALS), a third-generation synchrotron light source, has been recently commissioned. Beam diagnostics were very important to the success of the operation. Each diagnostic system is described in this paper along with detailed discussion of its performance. Some of the systems have been in operation for two years. Others, in the storage ring, have not yet been fully commissioned. These systems were, however, working well enough to provide the essential information needed to store beam. The devices described in this paper include wall current monitors, a beam charge monitor, a 50 ohm Faraday cup, DC current transformers, broad-hand striplines, fluorescence screens, beam collimators and scrapers, and beam position monitors. Also, the means by which waveforms are digitized and displayed in the control room is discussed

  1. Biological effect of penetration controlled irradiation with ion beams

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, Atsushi; Shimizu, Takashi; Kikuchi, Masahiro; Kobayashi, Yasuhiko; Watanabe, Hiroshi [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment; Yamashita, Takao

    1997-03-01

    To investigate the effect of local irradiation with ion beams on biological systems, technique for penetration controlled irradiation has been established. The range in a target was controlled by changing the distance from beam window in the atmosphere, and could be controlled linearly up to about 31 {mu}m in biological material. In addition, the effects of the penetration controlled irradiations with 1.5 MeV/u C and He ions were examined using tobacco pollen. The increased frequency of leaky pollen produced by ion beams suggests that the efficient pollen envelope damages would be induced at the range-end of ion beams. (author)

  2. Antares beam-alignment-system performance

    International Nuclear Information System (INIS)

    The beam alignment system for the 24-beam-sector Antares CO2 fusion laser automatically aligns more than 200 optical elements. A visible-wavelength alignment technique is employed which uses a telescope/TV system to view point-light sources appropriately located down the beamline. The centroids of the light spots are determined by a video tracker, which generates error signals used by the computer control system to move appropriate mirrors in a closed-loop system. Final touch-up alignment is accomplished by projecting a CO2 alignment laser beam through the system and sensing its position at the target location. The techniques and control algorithms employed have resulted in alignment accuracies exceeding design requirements. By employing video processing to determine the centroids of diffraction images and by averaging over multiple TV frames, we achieve alignment accuracies better than 0.1 times system diffraction limits in the presence of air turbulence

  3. Beam Loss Control for the Fermilab Main Injector

    CERN Document Server

    Brown, Bruce C

    2013-01-01

    From 2005 through 2012, the Fermilab Main Injector provided intense beams of 120 GeV protons to produce neutrino beams and antiprotons. Hardware improvements in conjunction with improved diagnostics allowed the system to reach sustained operation at 400 kW beam power. Losses were at or near the 8 GeV injection energy where 95% beam transmission results in about 1.5 kW of beam loss. By minimizing and localizing loss, residual radiation levels fell while beam power was doubled. Lost beam was directed to either the collimation system or to the beam abort. Critical apertures were increased while improved instrumentation allowed optimal use of available apertures. We will summarize the impact of various loss control tools and the status and trends in residual radiation in the Main Injector.

  4. Precision digital control systems

    Science.gov (United States)

    Vyskub, V. G.; Rozov, B. S.; Savelev, V. I.

    This book is concerned with the characteristics of digital control systems of great accuracy. A classification of such systems is considered along with aspects of stabilization, programmable control applications, digital tracking systems and servomechanisms, and precision systems for the control of a scanning laser beam. Other topics explored are related to systems of proportional control, linear devices and methods for increasing precision, approaches for further decreasing the response time in the case of high-speed operation, possibilities for the implementation of a logical control law, and methods for the study of precision digital control systems. A description is presented of precision automatic control systems which make use of electronic computers, taking into account the existing possibilities for an employment of computers in automatic control systems, approaches and studies required for including a computer in such control systems, and an analysis of the structure of automatic control systems with computers. Attention is also given to functional blocks in the considered systems.

  5. PEP instrumentation and control system

    International Nuclear Information System (INIS)

    This paper describes the operating characteristics of the primary components that form the PEP Instrumentation and Control System. Descriptions are provided for the computer control system, beam monitors, and other support systems

  6. TFTR neutral beam injection system conceptual design

    International Nuclear Information System (INIS)

    Three subsystems are described in the following chapters: (1) Neutral Beam Injection Line; (2) Power Supplies; and (3) Controls. Each chapter contains two sections: (1) Functions and Design Requirements; this is a brief listing of the requirements of components of the subsystem. (2) Design Description; this section describes the design and cost estimates. The overall performance requirements of the neutral beam injection system are summarized. (MOW)

  7. Design of Control System Device for Electron Gun Power Supply of 350 keV/10 mA Electron Beam Machine

    International Nuclear Information System (INIS)

    The electron gun power supply control system of electron beam machine has been designed. Using this design regulator device for the electron gun power supply will be constructed. This regulator device was designed that it can be operated manually or automatically. Beside that, this was also provided with the safety system which is useful to scram the MBE when something wrong happened. The main components of the device are remote data communication system using infra red and fiber optic module, DC motor driver system, regulated transformer coupled by DC motor and operation panel system. (author)

  8. Maritime adaptive optics beam control

    OpenAIRE

    Corley, Melissa S.

    2010-01-01

    The Navy is interested in developing systems for horizontal, near ocean surface, high-energy laser propagation through the atmosphere. Laser propagation in the maritime environment requires adaptive optics control of aberrations caused by atmospheric distortion. In this research, a multichannel transverse adaptive filter is formulated in Matlab's Simulink environment and compared to a complex lattice filter that has previously been implemented in large system simulations. The adaptive fil...

  9. Beam Cleaning and Collimation Systems

    CERN Document Server

    Redaelli, S

    2016-01-01

    Collimation systems in particle accelerators are designed to dispose of unavoidable losses safely and efficiently during beam operation. Different roles are required for different types of accelerator. The present state of the art in beam collimation is exemplified in high-intensity, high-energy superconducting hadron colliders, like the CERN Large Hadron Collider (LHC), where stored beam energies reach levels up to several orders of magnitude higher than the tiny energies required to quench cold magnets. Collimation systems are essential systems for the daily operation of these modern machines. In this document, the design of a multistage collimation system is reviewed, taking the LHC as an example case study. In this case, unprecedented cleaning performance has been achieved, together with a system complexity comparable to no other accelerator. Aspects related to collimator design and operational challenges of large collimation systems are also addressed.

  10. Beam steering system

    Science.gov (United States)

    Bowhill, S. A.; Merewether, K. O.

    1986-01-01

    A simple technique for steering the beam of a multimodule phased array MST (mesosphere, stratosphere, troposphere) radar antenna is described. It is desirable to be able to point the antenna in multiple directions, so as to derive all components of the horizontal velocity. This was done on an experimental basis by adding parallel wire line to the feed and achieving a southward tilt of the antenna. It is proved possible to steer the beam through most of the available range without adversely affecting the VSWR seen from the transmitter. Calibrating the antenna direction can be accomplished by observing radio sources, though there are an inadequate number to cover all directions. For various assumed values of the aspect sensitivity in dB/deg, and the calculated antenna pattern, it is possible to calculate the effective pointing angle of the antenna, defined as that angle which would give an identical location for the centroid of the power spectrum if aspect sensitivity were absent. Using averaged apparent steering directions, eastward and northward winds were calculated for special radar runs simultaneous with 14 balloon launches at Peoria and results are presented.

  11. The SSC beam scraper system

    Energy Technology Data Exchange (ETDEWEB)

    Maslov, M.A.; Mokhov, N.V.; Yazynin (Superconducting Super Collider Lab., Dallas, TX (United States) Institut Fiziki Vysokikh Ehnergij, Protvino (USSR))

    1991-06-01

    In this paper we present the results of a full-scale study of a beam scraping system that is designed to guarantee reliable operation of the SSC throughout the whole cycle and for minimum background for experiments at the interaction regions. The machine aperture limits and beam loss formation are analyzed. Simulation programs and a calculational model are described. The physics of beam scraping is explored, and measures to increase significantly the system efficiency are determined. A tolerable scraping rate, taking into account scraper material integrity, quench limits in downstream superconducting magnets, radiation shielding requirements, and minimal beam halo levels at the IPs are also determined. Finally, a complete multi-component scraper system in the SSC East Cluster is proposed. Throughout the paper we define a scraper as a primary absorber consisting of precise movable jaws that have a flat inner edge along the circulation beam and which may be forced to touch the beam halo in horizontal or vertical planes. Secondary absorbers -- collimators -- are destined to intercept outscattered protons and other particles produced in scraper material. All these are surrounded with a radiation shielding. 15 refs., 50 figs., 13 tabs.

  12. Resonant vibration control of rotating beams

    DEFF Research Database (Denmark)

    Svendsen, Martin Nymann; Krenk, Steen; Høgsberg, Jan Becker

    2011-01-01

    by an active strut, connecting two cross-sections of a rotating beam. The structure is modeled by beam elements in a rotating frame of reference following the beam. The geometric stiffness is derived in a compact form from an initial stress formulation in terms of section forces and moments. The...... stiffness, and there by the natural frequencies, of the beam depend on the rotation speed and the controller is tuned to current rotation speed to match the resonance frequency of the selected mode. It is demonstrated that resonant control leads to introduction of the intended level of damping in the...

  13. Beam position monitoring electronics system for LEHIPA

    International Nuclear Information System (INIS)

    The primary function of beam position monitoring system (BPM) is to determine the position of the beam with respect to the centre of beam pipe. The present system is VME based and mainly consists of two VME boards one Analog and one Digital. The system has been developed for 352.21 MHz Low Energy High Intensity Proton Accelerator (LEHIPA). The electronic system processes the signals coming from the sensor which incorporates four button pick-ups placed orthogonally around the beam pipe. The fundamental component of the beam signal is extracted from the signals from the sensor and amplified with gain stabilized amplifiers on the analog board. Offset tone based technique has been used for the stabilization of the gain of the amplifiers against changes in temperature, power supply, etc. The filtered and amplified signals are given to the digital board for digitization and further processing. The signal processing consists of demodulation in I-Q domain followed by CORDIC which gives the signal information in the form of amplitude and phase. The stabilization of the gain is also carried out in the digital domain. The phase information can be utilized for energy gain measurements. The amplitudes give the position of the beam which is calculated online in FPGA using difference over sum method. The EPICS system has been chosen as the basic framework for command control. The hardware architecture is as per standard VME crate. (author)

  14. Development of a postal system for dosimetry quality control performed in photon beams produced by linear accelerators of clinical use

    International Nuclear Information System (INIS)

    In this work a different system is proposed which is able to verify the absorbed depth dose given at two different depths, the irradiation field homogeneity and its coincidence with the light field of the machine, the source to surface distance used and the beam nominal energy. These radiation field parameters are very important in the tumour treatment and they may help in the determination of the error sources of the absorbed depth dose. The system developed uses a water phantom, LiF thermoluminescent dosemeters and a radiographic film to evaluate such parameters. The postal system developed in this work has been tested in linear accelerators of 4 to 18 MV with good results. (author)

  15. Plasma Charge Current for Controlling and Monitoring Electron Beam Welding with Beam Oscillation

    Science.gov (United States)

    Trushnikov, Dmitriy; Belenkiy, Vladimir; Shchavlev, Valeriy; Piskunov, Anatoliy; Abdullin, Aleksandr; Mladenov, Georgy

    2012-01-01

    Electron beam welding (EBW) shows certain problems with the control of focus regime. The electron beam focus can be controlled in electron-beam welding based on the parameters of a secondary signal. In this case, the parameters like secondary emissions and focus coil current have extreme relationships. There are two values of focus coil current which provide equal value signal parameters. Therefore, adaptive systems of electron beam focus control use low-frequency scanning of focus, which substantially limits the operation speed of these systems and has a negative effect on weld joint quality. The purpose of this study is to develop a method for operational control of the electron beam focus during welding in the deep penetration mode. The method uses the plasma charge current signal as an additional informational parameter. This parameter allows identification of the electron beam focus regime in electron-beam welding without application of additional low-frequency scanning of focus. It can be used for working out operational electron beam control methods focusing exactly on the welding. In addition, use of this parameter allows one to observe the shape of the keyhole during the welding process. PMID:23242276

  16. Antiproton source beam position system

    International Nuclear Information System (INIS)

    The TeV I Beam Position Monitor (BPM) system is designed to provide a useful diagnostic tool during the commissioning and operational phases of the antiproton source. Simply stated the design goal is to provide single turn position information for intensities of > 1x109 particles, and multi-turn (clocked orbit) information for beam intensities of > 1x107 particles, both with sub-millimeter resolution. It is anticipated that the system will be used during commissioning for establishing the first turn through the Debuncher and Accumulator, for aligning injection orbits, for providing information necessary to correct closed orbits, and for measuring various machine parameters (e.g. tunes, dispersion, aperture, chromaticity). During normal antiproton operation the system will be used to monitor the beam position throughout the accumulation process

  17. Active Vibration Control of Piezolaminated Smart Beams

    Directory of Open Access Journals (Sweden)

    V. Balamurugan

    2001-04-01

    Full Text Available This paper deals with the active vibration control of beam like structures with distributed piezoelectric sensor and actuator layers bonded on top and bottom surfaces of the beam. A finite element model based on Euler-Bernoulli beam theory has been developed. The contribution of the piezoelectric sensor and actuator layers on the mass and stiffness of the beam is considered. Three types of classical control strategies, namely direct proportional feedback, constant-gain negative velocity feedback and Lyapunov feedback and an optimal control strategy, linear quadratic regulator (LQR scheme are applied to study their control effectiveness. Also, the control performance with different types of loading, such as impulse loading, step loading, harmonic and random loading is studied

  18. Investigations of e-beam controlled diffuse discharges

    International Nuclear Information System (INIS)

    Externally controlled diffuse discharges have attracted considerable interest as submicrosecond opening switches for inductive energy storage systems. Their performance is strongly determined by the basic fill gas parameters and their dependence on the reduced field strength E/N. An electron-beam controlled diffuse discharge system was constructed to study the behavior of pulsed discharges in various gas mixtures under repetitive operation. The 200 kV, 400 A e-beam gun with thermionic cathode is designed as a tetrode. The control grid is pulsed to generate several successive e-beam pulses of 100 ns duration and variable pulse separation. Experiments were performed with 1 atm N/sub 2/ and small additives of attachers as fill gas in the e-beam controlled switch. The experimental results are compared with numerical values, obtained from a code which allows modeling of the discharge voltage-current characteristic and its transient behavior in a discharge circuit

  19. Step Motor Control System

    Institute of Scientific and Technical Information of China (English)

    ZhangShuochengt; WangDan; QiaoWeimin; JingLan

    2003-01-01

    All kinds of step motors and servomotors are widely used in CSR control system, such as many vacuum valves control that set on the HIRFL-CSR; all kinds of electric switches and knobs of ECR Ion Source; equipment of CSR Beam Diagnostics and a lot of large equipment like Inside Gun Toroid and Collector Toroid of HIRFL. A typical control system include up to 32 16-I/O Control boards, and each 16-I/O Control board can control 4 motors at the same time (including 8 Limit Switches).

  20. ATF neutral beam injection system

    International Nuclear Information System (INIS)

    The Advanced Toroidal Facility is a stellarator torsatron being built at Oak Ridge National Laboratory to investigate improved plasma confinement schemes. Plasmas heating will be carried out predominantly by means of neutral beam injection. This paper describes the basic parameters of the injection system. Numerical calculations were done to optimize the aiming of the injectors. The results of these calculations and their implications on the neutral power to the machine are elaborated. The effects of improving the beam optics and altering the focal length on the power transmitted to the plasma are discussed

  1. Automated beam steering using optimal control

    International Nuclear Information System (INIS)

    We present a steering algorithm which, with the aid of a model, allows the user to specify beam behavior throughout a beamline, rather than just at specified beam position monitor (BPM) locations. The model is used primarily to compute the values of the beam phase vectors from BPM measurements, and to define cost functions that describe the steering objectives. The steering problem is formulated as constrained optimization problem; however, by applying optimal control theory we can reduce it to an unconstrained optimization whose dimension is the number of control signals.

  2. Beam systems without failures - What can be done?

    International Nuclear Information System (INIS)

    The beam dumps at 3.5 TeV triggered by interlocks not related to the magnet powering are discussed. This concerns the systems like the RF, the transverse feedbacks, beam instrumentation, beam dumping system, collimators and control systems. An analysis of the reasons of these dumps is presented together with a possible strategy to mitigate the effect of these failures. It is very important to notice that no system has been identified to have any structural problem

  3. Beam Instrumentation Using BPM System of the SPring-8 Linac

    CERN Document Server

    Yanagida, K; Dewa, H; Hanaki, H; Kobayashi, T; Mizuno, A; Suzuki, S; Taniuchi, T; Tomizawa, H

    2004-01-01

    A beam position monitor (BPM) system of the SPring-8 linac has been operated since 2002. The following upgrade programs have been carried out during this period: The BPMs were installed in the linac's dispersive sections. A synchronized accumulation of beam position data into the database system started. A feedback control of steering magnets for beam position stabilization has been under development. In this conference the authors report a performance of the BPM system, and discuss its usefulness for beam diagnostics, machine diagnostics and beam stabilization.

  4. The Saturne beam measurement system for orbit corrections and high and low intensity beam acceleration

    International Nuclear Information System (INIS)

    This paper summarizes the dipolar and multipolar correction system and the main beam diagnostics of Saturne II: wide-band RF electrostatic pick-up electrode for observation of bunches, beam position and tune measurement systems, special electrodes for observation of emittance blow-up when particles cross a resonance line. For low intensity beams, special electrodes and electronics have been developed. All this instrumentation is computer controlled

  5. The N8 channel beam loss monitor system

    International Nuclear Information System (INIS)

    High intensity 70 GeV proton beam loss monitor system architecture in the area of single beam pass is described. The main system components choosing as detectors recording and controlling electronics are grounded on. There are list of the main system monitoring tasks and some experimental results. 12 refs.; 6 figs

  6. A simple method for the quality control of the isocenter of cone beam CT for Elekta Accelerator system Synery; Un metodo sencillo para el control de calidad del isocentro del sistema Cone Beam CT para un acelerador Elekta Synery

    Energy Technology Data Exchange (ETDEWEB)

    Clemente Gutierrez, F.; Perez Vara, C.; Prieto Villacorta, M.

    2013-07-01

    Techniques of image-guided radiation therapy has been spreading over the past years. Cone-beam tomography systems constitute a particular case. As any team that employs ionizing radiation in the diagnosis or treatment of patients, such a system must be seen within a guarantee program of quality according to the recommendations and regulations. In particular, between geometric proofs referred to in such a program for these systems, must be referred to the verification of the coincidence between the isocentres of the treatment unit and the team's image. This work includes the weekly procedure followed for such verification. (Author)

  7. Toward design of the Collider Beam Collimation System

    International Nuclear Information System (INIS)

    A multi-component beam collimation system for the Superconducting Super Collider is described. System choice justification and design requirements are presented. System consists of targets, scrapers, and collimators with appropriate cooling and radiation shielding. Each component has an independent control for positioning and aligning with respect to the beam. Results of beam loss distribution, energy deposition calculations, and thermal analyses, as well as cost estimate, are presented

  8. Digital feed back control for radial beam position

    International Nuclear Information System (INIS)

    In the development of wide spread large scale distributed digital control systems, there is a requirement to automate small processes like radial beam control which will not only improve the beam quality but will also add local intelligence. Hence use is made here of digital control principles for such applications. The work concerned with the radial beam control discussed in this report has been developed for ISIS at RAL. The structure of the report is hence inclined more towards the local hardware system. The general feed back loop techniques can also be implemented for other control purpose. For instance, the author has successfully tested similar techniques to minimise the RF cavity tuning error, where the improvement in performance could not be matched by the analogue loop. A description of the RF cavity tuning programme and the associated experimental results will be published as a local paper for ISIS division. (author)

  9. KTeV beam systems design report

    Energy Technology Data Exchange (ETDEWEB)

    Bocean, V.; Childress, S.; Coleman, R. [and others

    1997-09-01

    The primary and secondary beams for the KTeV experiments E799-II and E832 are discussed. The specifications are presented and justified. The technical details of the implementation of the primary beam transport and stability are detailed. The target, beam dump, and radiation safety issues are discussed. The details of the collimation system for the pair of secondary beams are presented.

  10. KTeV beam systems design report

    International Nuclear Information System (INIS)

    The primary and secondary beams for the KTeV experiments E799-II and E832 are discussed. The specifications are presented and justified. The technical details of the implementation of the primary beam transport and stability are detailed. The target, beam dump, and radiation safety issues are discussed. The details of the collimation system for the pair of secondary beams are presented

  11. RHIC beam loss monitor system design

    International Nuclear Information System (INIS)

    The Beam Loss Monitor (BLM) System is designed to prevent the quenching of RHIC magnets due to beam loss, provide quantitative loss data, and the loss history in the event of a beam abort. The system uses 400 ion chambers of a modified Tevatron design. To satisfy fast (single turn) and slow (100 msec) loss beam criteria and provide sensitivity for studies measurements, a range of over 8 decades is needed. An RC pre-integrator reduces the dynamic range for a low current amplifier. This is digitized for data logging. The output is also applied to an analog multiplier which compensates the energy dependence, extending the range of the abort comparators. High and low pass filters separate the signal to dual comparators with independent programmable trip levels. Up to 64 channels, on 8 VME boards, are controlled by a micro-controller based VME module, decoupling it from the front-end computer (FEC) for real-time operation. Results with the detectors in the RHIC Sextant Test and the electronics in the AGS-to-RHIC (AtR) transfer line will be presented

  12. High power neutral beam systems

    International Nuclear Information System (INIS)

    Spurred by the requirement to supply megawatts of power to heat magnetically confined plasmas to temperatures of interest for fusion research, a new class of low energy, high power accelerators termed neutral beam injectors has been developed. Industry has played an important role in building upon technology advances at the national laboratories to engineer neutral beam injectors to meet the needs of specific users. A brief retrospective of the field is presented, with emphasis upon one particular application, that of DIII-D, a large tokamak at General Atomics. In this instance, the role of industry has been especially extensive because the user/system integrator is itself an industrial concern. 4 refs., 7 figs., 2 tabs

  13. Requirements of CLIC Beam Loss Monitoring System

    CERN Document Server

    Sapinski, M; Holzer, EB; Jonker, M; Mallows, S; Otto, T; Welsch, C

    2010-01-01

    The Compact Linear Collider (CLIC) [1] is a proposed multi-TeV linear electron-positron collider being designed by a world-wide collaboration. It is based on a novel twobeam acceleration scheme in which two beams (drive and main beam) are placed in parallel to each other and energy is transferred from the drive beam to the main one. Beam losses on either of them can have catastrophic consequences for the machine, because of high intensity (drive beam) or high energy and small emittance (main beam). In the framework of machine protection, a Beam Loss Monitoring (BLM) system has to be put in place. This paper discusses the requirements for the beam loss system in terms of detector sensitivity, resolution, dynamic range and ability to distinguish losses originating from various sources. The two-beam module where the protection from beam losses is particularly challenging and important, is studied.

  14. Digital test objects (D.T.O.) for treatment planning systems quality control in external beam radiotherapy

    International Nuclear Information System (INIS)

    This work presents the conception and implementation of new automatic and quantitative quality assessment methods for geometric treatment planning in external radiotherapy. Treatment planning Systems (T.P.S.) quality control is mandatory in France and in the world because of encountered risks but the physical tools recommended to lead this quality control are not adapted to the situation. We present a new methodology for control quality based on the definition of Digital Test Objects (D.T.O.) that are directly introduced in the T.P.S. without acquisition device. These D.T.O. are consistently defined in a continuous and discrete modes. The T.P.S. responses to input D.T.O. are compared to theoretical results thanks to figures of merit specifically designed for each elementary control. The tests we carried out during this study allow to validate our solutions for the quality assessment of the auto-contouring, auto-margining, isocenter computation, collimator conformation and digitally reconstructed radiograph generation tools, as well as our solutions for marker positioning, collimator and displayed bean rotation, incidence, divergence and dimensions. Quality assessment solutions we propose are then fast and effective (no acquisition by the device, reduced manipulations), and more precise thanks to the continuous-discrete equivalence realized at the beginning of the modelling

  15. Development of KSTAR Neutral Beam Heating System

    Energy Technology Data Exchange (ETDEWEB)

    Oh, B. H.; Song, W. S.; Yoon, B. J. (and others)

    2007-10-15

    The prototype components of a neutral beam injection (NBI) system have been developed for the KSTAR, and a capability of the manufactured components has been tested. High power ion source, acceleration power supply, other ion source power supplies, neutralizer, bending magnet for ion beam separation, calorimeter, and cryo-sorption pump have been developed by using the domestic technologies and tested for a neutral beam injection of 8 MW per beamline with a pulse duration of 300 seconds. The developed components have been continuously upgraded to achieve the design requirements. The development technology of high power and long pulse neutral beam injection system has been proved with the achievement of 5.2 MW output for a short pulse length and 1.6 MW output for a pulse length of 300 seconds. Using these development technologies, the domestic NB technology has been stabilized under the development of high power ion source, NB beamline components, high voltage and current power supplies, NB diagnostics, NB system operation and control.

  16. Neutral particle beam distributed data acquisition system

    Energy Technology Data Exchange (ETDEWEB)

    Daly, R.T.; Kraimer, M.R.; Novick, A.H.

    1987-01-01

    A distributed data acquisition system has been designed to support experiments at the Argonne Neutral Particle Beam Accelerator. The system uses a host VAXstation II/GPX computer acting as an experimenter's station linked via Ethernet with multiple MicroVAX IIs and rtVAXs dedicated to acquiring data and controlling hardware at remote sites. This paper describes the hardware design of the system, the applications support software on the host and target computers, and the real-time performance.

  17. The beam delivery modeling and error sources analysis of beam stabilization system for lithography

    Science.gov (United States)

    Wang, Jun; Huang, Lihua; Hou, Liying; He, Guojun; Ren, Bingqiang; Zeng, Aijun; Huang, Huijie

    2013-12-01

    Beam stabilization system is one of the most important units for lithography, which can accomplish displacement and pointing detection and control and includes beam measurement unit(BMU) and beam steering unit(BSU). Our group has set up a beam stabilization system and verified preliminarily beam stabilization algorithm of precise control beam position and angle. In the article, we establish beam delivery mathematic model and analyze the system inherent error. This shows that the reason why image rotation effect arises at the output plane of beam stabilization is the fast steering mirror (FSM) rotation of BSU in the process of beam stabilization. Two FSMs rotation around 45o axis of FSM make the most contribution to image rotation which rotates 1.414 mrad as two FSMs rotation angle difference changes 1 mrad. It is found that error sources include three key points: FSM accuracy; measurement noise and beam translation by passing through of beam splitters changing as the ambient temperature changing. FSM accuracy leads to the maximum 13.2μm displacement error and 24.49μrad angle error. Measurement inaccuracy as a result of 5μm measurement noise results in the maximum 0.126mm displacement error and 57.2μrad angle error. Beam translation errors can be negligible if temperature is unchanged. We have achieved beam stability of about 15.5μrad for angle and 28μm for displacement (both 1σ) after correcting 2mm initial displacement deviation and 5mrad initial angle deviation with regard to the system rebuilt due to practical requirements.

  18. Low power RF beam control electronics for the LEB

    International Nuclear Information System (INIS)

    Beam Control Electronics for the Low Energy Booster (LEB) should provide a fine reference phase and frequency for the High Power RF System. Corrections applied on the frequency of the rf signal will reduce dipole synchrotron oscillations due to power supply regulation errors, errors in frequency source or errors in the cavity voltage. It will allow programmed beam radial position control throughout the LEB acceleration cycle. Furthermore the rf signal provides necessary connections during, adiabatic capture of the beam as injected into the LEB by the Linac and will guarantee LEB rf phase synchronism with the Medium Energy Booster (MEB) rf at a programmed time in the LEB cycle between a unique LEB bucket and a unique MEB bucket. We show in this paper a design and possible interfaces with other subsystems of the LEB such as the beam instrumentation, High Power RF Stations, global accelerator controls and the precision timing system. The outline of various components of the beam control system is also presented followed by some test results

  19. Low power RF beam control electronics for the LEB

    Energy Technology Data Exchange (ETDEWEB)

    Mestha, L.K.; Mangino, J.; Brouk, V.; Uher, T.; Webber, R.C.

    1993-05-01

    Beam Control Electronics for the Low Energy Booster (LEB) should provide a fine reference phase and frequency for the High Power RF System. Corrections applied on the frequency of the rf signal will reduce dipole synchrotron oscillations due to power supply regulation errors, errors in frequency source or errors in the cavity voltage. It will allow programmed beam radial position control throughout the LEB acceleration cycle. Furthermore the rf signal provides necessary connections during, adiabatic capture of the beam as injected into the LEB by the Linac and will guarantee LEB rf phase synchronism with the Medium Energy Booster (MEB) rf at a programmed time in the LEB cycle between a unique LEB bucket and a unique MEB bucket. We show in this paper a design and possible interfaces with other subsystems of the LEB such as the beam instrumentation, High Power RF Stations, global accelerator controls and the precision timing system. The outline of various components of the beam control system is also presented followed by some test results.

  20. Neutral Beam Power System for TPX

    International Nuclear Information System (INIS)

    The Tokamak Physics Experiment (TPX) will utilize to the maximum extent the existing Tokamak Fusion Test Reactor (TFTR) equipment and facilities. This is particularly true for the TFTR Neutral Beam (NB) system. Most of the NB hardware, plant facilities, auxiliary sub-systems, power systems, service infrastructure, and control systems can be used as is. The major changes in the NB hardware are driven by the new operating duty cycle. The TFTR Neutral Beam was designed for operation of the Sources for 2 seconds every 150 seconds. The TPX requires operation for 1000 seconds every 4500 seconds. During the Conceptual Design Phase of TPX every component of the TFTR NB Electrical Power System was analyzed to verify whether the equipment can meet the new operational requirements with our without modifications. The Power System converts 13.8 kV prime power to controlled pulsed power required at the NB sources. The major equipment involved are circuit breakers, auto and rectifier transformers surge suppression components, power tetrodes, HV Decks, and HVDC power transmission to sources. Thermal models were developed for the power transformers to simulate the new operational requirements. Heat runs were conducted for the power tetrodes to verify capability. Other components were analyzed to verify their thermal limitations. This paper describes the details of the evaluation and redesign of the electrical power system components to meet the TPX operational requirements

  1. Quality control beam of radiation through imaging system using a flat panel (ILD); Control de calidad de haz de radiacion mediante un sistema de imagen de panel plano (EPID)

    Energy Technology Data Exchange (ETDEWEB)

    Benitez Serrano, J. A.; Gomez Barrado, A.; Sanchez-Reyes, A.

    2013-07-01

    The daily quality checks of the accelerator include, among others, checks of the daily calibration, symmetry and uniformity of the radiation beam. Usually verification systems daily are used for this purpose, which employ arrays of detectors of solid-state or ionization chambers. This paper intends to carry out the control of quality through the irradiation of a number of fields in the portal imaging system and its subsequent analysis in software's own creation, as well as the comparison of results with the daily verification system. (Author)

  2. PLS linac instrument and control system

    International Nuclear Information System (INIS)

    A plan for the instrument and control system of the PLS (Pohang Light Source) 2 GeV linear accelerator is described. Major beam diagnostic instruments consist of 2 ns beam current monitors, beam profile monitors, and beam loss monitors. The control system will adopt the VME bus. For the timing system, the basic timing pulses will be obtained from the storage ring's RF master oscillator and distributed to the gun pulser and klystrons through the time delay electronic modules

  3. Data acquisition system for KOMAC beam monitoring using EPICS middleware

    Science.gov (United States)

    Song, Young-Gi

    2015-10-01

    The beam diagnostics instrument used to measure the beam properties is one of the important devices for the 100-MeV proton linear accelerator of the KOrea Multi-purpose Accelerator Complex (KOMAC). A data acquisition system (DAQ) is required to collect the output beam signals conditioned in the analog front-end circuitry of a beam loss monitor (BLM) and a beam position monitor (BPM). The electrical beam signal must be digitized, and the sampling has to be synchronized to a global timing system that produces a pulse signal for the pulsed beam operation. The digitized data must be accessible by the experimental physics and industrial control system (EPICS)-based control system, which manages all accelerator control. An input output controller (IOC), which runs Linux on a central process unit (CPU) module with a peripheral component interconnect (PCI) express-based Analog-to-digital converter (ADC) card, has been adopted to satisfy the requirements. An associated Linux driver and EPICS device support module have also been developed. The IOC meets the requirements, and the development and maintenance of software for the IOC is very efficient. In this paper, the details of the DAQ system for the BLM and the BPM with the introduction of the KOMAC beam-diagnostics devices, along with the performance, are described.

  4. Reliability Analysis of the new Link between the Beam Interlock System and the LHC Beam Dumping System Zuverlässigkeitsanalyse der neuen Verbindung zwischen dem Beam Interlock System und dem LHC Beam Dumping System

    CERN Document Server

    Vatansever, Volkan

    The nominal stored energy in each LHC beam is 360 MJ, surpassing the beam energy of other accelerators by orders of magnitude. This energy threatens to damage accelerator components in case of uncontrolled beam losses To avoid damage of accelerator equipment due to impacting beam, the controlled removal of the LHC beams from the collider rings towards the dump block must be guaranteed at all times. Therefore, the LHC Beam Dumping System was built according to high reliability standards. To further reduce the risk of incapability to dump the beams in case of correlated failures in the redundant system, a new direct link from the LHC Beam Interlock System to the Re-triggering Lines of the LHC Beam Dumping System will be implemented for the startup with beam in 2015. This link represents a diverse redundancy to the current implementation, which should neither significantly increase the risk for so-called Asynchronous Beam Dumps nor compromise machine availability. Therefore, a reliability analysis down to the co...

  5. Computer control system in RIBLL

    International Nuclear Information System (INIS)

    The Computer Control System applied in the Radioactive Ion Beam Line Lanzhou (RIBLL) is introduced. Accurate motion and position of ion beam diagnosing devices and detecting elements controlled by computer are emphatically described. It consists of the characteristics and working principle of step motor model 86BYG450B-02. Its computer interface circuit, and controlling program flow coded in Microsoft Visual C++ based on Windows NT or Windows 95 are introduced as well

  6. Ion beam figuring system in NUDT

    Science.gov (United States)

    Zhou, Lin; Xie, Xuhui; Dai, Yifan; Jiao, Changjun; Li, Shengyi

    2007-12-01

    Ion beam figuring (IBF) is an optical fabrication technique that provides highly deterministic process to correct surface figure error of previously polished surfaces by using a directed, inert and neutralized ion beam to physically sputter material from the optic surface. Recently, an ion beam figuring system KDIFS-500 has been designed and built in National University of Defense Technology (NUDT) of the P.R. China. KDIFS-500 is capable of processing workpiece up to Φ500mm. Line scanning process was discussed in detail for estimating the parameters of the beam removal function (BRF) in process. Experiments were conducted to demonstrate that the BRF increases gradually in process and by employing a stability control, the BRF can be kept stable in process. Finally, a Φ95 mm plano optical sample of CVD coated SiC substrate has been figured in two process iterations for demonstrating the correction capability of the KDIFS-500. Their figure convergence ratios reached 5.8 and 2.1 respectively. The actual figure residual errors were basically consistent with the predicted error. These consistencies indicated that the IBF processes on KDIFS-500 are predictable deterministic processes.

  7. Spiral kicker for the beam abort system

    Energy Technology Data Exchange (ETDEWEB)

    Martin, R.L.

    1983-01-01

    A brief study was carried out to determine the feasibility of a special kicker to produce a damped spiral beam at the beam dump for the beam abort system. There appears to be no problem with realizing this concept at a reasonably low cost.

  8. Optimal centralized and decentralized velocity feedback control on a beam

    International Nuclear Information System (INIS)

    This paper considers the optimization of a velocity feedback controller with a collocated force actuator, to minimize the kinetic energy of a simply supported beam. If the beam is excited at a single location, the optimum feedback gain varies with the position of the control system. It is shown that this variation depends partly on the location of the control force relative to the exciting force. If a distributed excitation is assumed, that is random in both time and space, a unique optimum value of the feedback gain can be found for a given control location. The effect of the control location on performance and the optimal feedback gain can then be examined and is found to be limited provided the control locations are not close to the ends of the beam. The optimization can also be performed for a multichannel velocity feedback system. Both a centralized and a decentralized controller are considered. It is shown that the difference in performance between a centralized and a decentralized controller is small, unless the control locations are closely spaced. In this case the centralized controller effectively feeds back a moment proportional to angular velocity as well as a force proportional to a velocity. It is also shown that the optimal feedback gain can be approximated on the basis of a limited model and that similar results can be achieved

  9. Sensor enabled closed-loop bending control of soft beams

    Science.gov (United States)

    Case, Jennifer C.; White, Edward L.; Kramer, Rebecca K.

    2016-04-01

    Control of soft-bodied systems is challenging, as the absence of rigidity typically implies distributed deformations and infinite degrees-of-freedom. In this paper, we demonstrate closed-loop control of three elastomer beams that vary in bending stiffness. The most stiff beam is comprised of a single prismatic structure made from a single elastomer. In the next beam, increased flexibility is introduced via an indentation in the elastomer, forming a joint. The most flexible beam uses a softer elastomer in the joint section, along with an indentation. An antagonistic pair of actuators bend the joint while a pair of liquid-metal-embedded strain sensors provide angle feedback to a control loop. We were able to achieve control of the system with a proportional-integral-derivative control algorithm. The procedure we demonstrate in this work is not dependent on actuator and sensor choice and could be applied to to other hardware systems, as well as more complex multi-joint robotic structures in the future.

  10. Beaconless adaptive-optics technique for HEL beam control

    Science.gov (United States)

    Khizhnyak, Anatoliy; Markov, Vladimir

    2016-05-01

    Effective performance of forthcoming laser systems capable of power delivery on a distant target requires an adaptive optics system to correct atmospheric perturbations on the laser beam. The turbulence-induced effects are responsible for beam wobbling, wandering, and intensity scintillation, resulting in degradation of the beam quality and power density on the target. Adaptive optics methods are used to compensate for these negative effects. In its turn, operation of the AOS system requires a reference wave that can be generated by the beacon on the target. This report discusses a beaconless approach for wavefront correction with its performance based on the detection of the target-scattered light. Postprocessing of the beacon-generated light field enables retrieval and detailed characterization of the turbulence-perturbed wavefront -data that is essential to control the adaptive optics module of a high-power laser system.

  11. Internally shielded beam transport and support system

    International Nuclear Information System (INIS)

    Due to environmental concerns, the Advanced Photon Source has a policy that disallows any exposed lead within the facility. This creates a real problem for the beam transport system, not so much for the pipe but for the flexible coupling (bellows) sections. A complete internally shielded x-ray transport system, consisting of long transport lines joined by flexible coupling sections, has been designed for CARS sector 14 to operate either at high vacuum or as a helium flight tube. It can effectively shield against air scattering of wiggler or undulator white beam with proper placement of apertures, collimators, and masks for direct beam control. The system makes use of male- and female-style fittings that create a labyrinth allowing for continuous shielding through the flexible coupling sections. These parts are precision machined from a ternary hypereutectic lead alloy (cast under 15 inches of head pressure to assure a pinhole-free casting) then pressed into either end (rotatable vacuum flanges) of the bellows assembly. The transport pipe itself consists of a four part construction using a stepped transition ring (Z-ring) to connect an inner tube to the vacuum flange and also to a protective and supportive outer tube. The inner tube is wrapped with 1/16 double-prime pure lead sheet to a predetermined thickness following the shape of the stepped transition ring for continuous shielding. This design has been prototyped and radiation tested. copyright 1996 American Institute of Physics

  12. Switched steerable multiple beam antenna system

    Science.gov (United States)

    Iwasaki, Richard S.

    1988-09-01

    A steerable multibeam five element cross-feed cluster antenna system is described. The feed power is divided into five branches. Each branch includes a switching network comprised of a plurality of time delay elements each individually controlled by a respective electromagnetic latching switch. Frequency independent individual two-dimensional beam steering at intermediate (IF) scanning frequencies is thereby provided wherein discrete incremental time delays are introduced by the switching networks into each branch and the signals recombined thereafter to form each beam. The electromagnetic latched switching reduces power consumption and permits higher power switching and reciprocal coincident tranmsit and receive operation. Frequency independence due to incremental time delay switching permits coincident reciprocal operation and steering for transmit-receive signal paths carrying different transmit-receive frequencies. Diagonal quarter wave plates in the waveguides alter polarization from the circular to orthogonal linear to provide transmitter-receiver isolation.

  13. A simple electron-beam lithography system

    DEFF Research Database (Denmark)

    Mølhave, Kristian; Madsen, Dorte Nørgaard; Bøggild, Peter

    2005-01-01

    A large number of applications of electron-beam lithography (EBL) systems in nanotechnology have been demonstrated in recent years. In this paper we present a simple and general-purpose EBL system constructed by insertion of an electrostatic deflector plate system at the electron-beam exit of the...... be used to write three-dimensional nanostructures by electron-beam deposition. (C) 2004 Elsevier B.V. All rights reserved....

  14. High precision electron beam diagnostic system for high current long pulse beams

    International Nuclear Information System (INIS)

    As part of the effort to develop a multi-axis electron beam transport system using stripline kicker technology for DARHT II applications, it is necessary to precisely determine the position and extent of long high energy beams (6-40 MeV, 1-4 kA, 2 microseconds) for accurate position control. The kicker positioning system utilizes shot-to-shot adjustments for reduction of relatively slow (<20 MHz) motion of the beam centroid. The electron beams passing through the diagnostic systems have the potential for large halo effects that tend to corrupt measurements performed using capacitive pick-off probes. Likewise, transmission line traveling wave probes have problems with multi-bounce effects due to these longer pulse widths. Finally, the high energy densities experienced in these applications distort typical foil beam position measurements

  15. Control System Segmentation

    International Nuclear Information System (INIS)

    Over the past seven years, the Jefferson Lab's control system has grown to include more than two hundred distributed computers running over a complex segmented network, controlling a number of semi-independent operational plants. Several of the plants, including that used for running beam for physics users, operate around the clock with only brief, scheduled interruptions for machine repairs. Because of this, high control system availability is critical. Dividing computing resources into distinct sections, called fiefdoms, improves availability of the control system for each plant while facilitating periodic maintenance. In order to maximize uptime, each fiefdom operates as a completely independent control system consisting of a file server machine with a complete set of control system software and files, a local network, operator consoles and computers to execute high and low level control programs. The fiefdoms are isolated using network hardware, while still allowing limited communication between them. By segmenting the control system in this manner, the effect of a computer failure is minimized and machines can be taken down for periodic maintenance and upgrades without disabling other controls capabilities for the site

  16. THz beam steering by optical coherent control

    OpenAIRE

    Füser, Heiko; Bieler, Mark

    2013-01-01

    We demonstrate optical coherent control of the emission direction of THz radiation. Femtosecond laser pulses are used to excite different types of ultrafast photocurrents along different directions in a bulk GaAs sample. The overall emission pattern can be modified by changing the phase of the optical excitation. With this method, THz beam steering of about 8 degrees is realized. A simple dipole-based model allows us to relate the size of the steering effect to the amplitude ratio between the...

  17. X-ray beam deflection control with a flexible capillary

    International Nuclear Information System (INIS)

    X-ray beam deflection control method using a single flexible glass capillary is proposed to illuminate a fixed sample at a target position with different incidence angle. A 700 mm-long capillary with a bore diameter of 50 micron and an outer diameter of 2 mm, which gives suitable flexibility for the critical curvature, was employed for the test experiment in SPring-8. The X-ray beam with a wavelength of 0.1 nm was introduced into the capillary, whose axis at the input side was finely adjusted to be parallel to the X-ray beam axis with swivel-, rotation- and translation stages. The divergence angle of output beam was measured and is 1–2 mrad. By moving the output-side capillary-support transversely to the beam axis, the beam deflection angle was changed over the range of about 80 mrad. The maximum throughput was larger than 60 % in efficiency, and 8 × 1010 photons/s in flux. Mapping with the beam deflection system has also been demonstrated for X-ray absorption measurement of a test sample composed of copper and nickel films. The materials were identified by changing the X-ray photon energy around their absorption edges.

  18. LHC Beam Stability and Feedback Control - Orbit and Energy -

    CERN Document Server

    Steinhagen, R J

    2007-01-01

    This report presents the stability and control of the Large Hadron Collider's (LHC) two beam orbits and their particle momenta using beam-based feedback systems. The LHC, presently being built at CERN, will store, accelerate and provide particle collisions with a maximum particle momentum of 7TeV/c and a nominal luminosity of L = 10^34 cm^−2s^−1. The presence of two beams, with both high intensity as well as high particle energies, requires excellent control of particle losses inside a superconducting environment, which will be provided by the LHC Cleaning and Machine Protection System. The performance and function of this and other systems depends critically on the stability of the beam and may eventually limit the LHC performance. Environmental and accelerator-inherent sources as well as failure of magnets and their power converters may perturb and reduce beam stability and may consequently lead to an increase of particle loss inside the cryogenic mass. In order to counteract these disturbances, c...

  19. Use of beam deflection to control an electron beam wire deposition process

    Science.gov (United States)

    Taminger, Karen M. (Inventor); Hofmeister, William H. (Inventor); Hafley, Robert A. (Inventor)

    2013-01-01

    A method for controlling an electron beam process wherein a wire is melted and deposited on a substrate as a molten pool comprises generating the electron beam with a complex raster pattern, and directing the beam onto an outer surface of the wire to thereby control a location of the wire with respect to the molten pool. Directing the beam selectively heats the outer surface of the wire and maintains the position of the wire with respect to the molten pool. An apparatus for controlling an electron beam process includes a beam gun adapted for generating the electron beam, and a controller adapted for providing the electron beam with a complex raster pattern and for directing the electron beam onto an outer surface of the wire to control a location of the wire with respect to the molten pool.

  20. IGISOL control system modernization

    Science.gov (United States)

    Koponen, J.; Hakala, J.

    2016-06-01

    Since 2010, the IGISOL research facility at the Accelerator laboratory of the University of Jyväskylä has gone through major changes. Comparing the new IGISOL4 facility to the former IGISOL3 setup, the size of the facility has more than doubled, the length of the ion transport line has grown to about 50 m with several measurement setups and extension capabilities, and the accelerated ions can be fed to the facility from two different cyclotrons. The facility has evolved to a system comprising hundreds of manual, pneumatic and electronic devices. These changes have prompted the need to modernize also the facility control system taking care of monitoring and transporting the ion beams. In addition, the control system is also used for some scientific data acquisition tasks. Basic guidelines for the IGISOL control system update have been remote control, safety, usability, reliability and maintainability. Legacy components have had a major significance in the control system hardware and for the renewed control system software the Experimental Physics and Industrial Control System (EPICS) has been chosen as the architectural backbone.

  1. Adaptive robust control of longitudinal and transverse electron beam profiles

    Science.gov (United States)

    Rezaeizadeh, Amin; Schilcher, Thomas; Smith, Roy S.

    2016-05-01

    Feedback control of the longitudinal and transverse electron beam profiles are considered to be critical for beam control in accelerators. In the feedback scheme, the longitudinal or transverse beam profile is measured and compared to a desired profile to give an error estimate. The error is then used to act on the appropriate actuators to correct the profile. The role of the transverse feedback is to steer the beam in a particular trajectory, known as the "orbit." The common approach for orbit correction is based on approximately inverting the response matrix, and in the best case, involves regulating or filtering the singular values. In the current contribution, a more systematic and structured way of handling orbit correction is introduced giving robustness against uncertainties in the response matrix. Moreover, the input bounds are treated to avoid violating the limits of the corrector currents. The concept of the robust orbit correction has been successfully tested at the SwissFEL injector test facility. In the SwissFEL machine, a photo-injector laser system extracts electrons from a cathode and a similar robust control method is developed for the longitudinal feedback control of the current profile of the electron bunch. The method manipulates the angles of the crystals in the laser system to produce a desired charge distribution over the electron bunch length. This approach paves the way towards automation of laser pulse stacking.

  2. Integrated control system for LEHIPA

    International Nuclear Information System (INIS)

    The Low Energy High Intensity Proton Accelerator (LEHIPA) is a 20 MeV 30 mA proton accelerator which will be achieved in multiple stages. LEHIPA consists of several sub systems/devices located at different positions of the beam path which includes ION source, RF Power, RF Protection Interlock System, Low Conductivity Water plant, Low Level RF Control Systems, Vacuum System, Beam Diagnostics and Beam Line Devices. All these subsystems have their own local control systems (LCS) which will coordinate the operation of the corresponding subsystem. The control system for LEHIPA is thus being designed as a Distributed Control System with different teams developing each LCS. The control system will assist the operator to achieve a beam of desired characteristics by interacting with various sub systems of the accelerator in a seamless manner, protect the various parts of machine by generating the necessary interlocks, keep track of various parameters monitored periodically by suitably archiving them, alarms annunciation and trouble shoot from the control room. This paper describes approach to system design of ICS. (author)

  3. Tracking control of a flexible beam by nonlinear boundary feedback

    Directory of Open Access Journals (Sweden)

    Bao-Zhu Guo

    1995-01-01

    Full Text Available This paper is concerned with tracking control of a dynamic model consisting of a flexible beam rotated by a motor in a horizontal plane at the one end and a tip body rigidly attached at the free end. The well-posedness of the closed loop systems considering the dissipative nonlinear boundary feedback is discussed and the asymptotic stability about difference energy of the hybrid system is also investigated.

  4. Beam control in the ETA-II linear induction accelerator

    International Nuclear Information System (INIS)

    Corkscrew beam motion is caused by chromatic aberration and misalignment of a focusing system. We have taken some measures to control the corkscrew motion on the ETA-II induction accelerator. To minimize chromatic aberration, we have developed an energy compensation scheme which reduces energy sweep and differential phase advance within a beam pulse. To minimize the misalignment errors, we have developed a time-independent steering algorithm which minimizes the observed corkscrew amplitude averaged over the beam pulse. The steering algorithm can be used even if the monitor spacing is much greater than the system's cyclotron wavelength and the corkscrew motion caused by a given misaligned magnet is fully developed, i.e., the relative phase advance is greater than 2π. (Author) 5 figs., 11 refs

  5. Suppression of beam halo-chaos using nonlinear feedback discrete control method

    CERN Document Server

    Fang Jin Qing; Chen Guan Rong; Luo Xiao Shu; Weng Jia Qiang

    2002-01-01

    Based on nonlinear feedback control method, wavelet-based feedback controller as a especial nonlinear feedback function is designed for controlling beam halo-chaos in high-current accelerators of driven clean nuclear power system. PIC simulations show that suppression of beam halo-chaos are realized effectively after discrete control of wavelet-based feed-back is applied to five kinds of the initial proton beam distributions, respectively. The beam halo strength factor is quickly reduced to zero, and other statistical physical quantities of beam halo-chaos are more than doubly reduced. These performed PIC simulation results demonstrate that the developed methods are very effective for control of beam halo-chaos. Potential application of the beam halo-chaos control methods is discussed finally

  6. Digital Controller For Laser-Beam-Steering Subsystem: Part 2

    Science.gov (United States)

    Ansari, Homayoon; Voisinet, Leeann

    1995-01-01

    A report presents additional information about laser-beam-steering apparatus described in "Digital Controller for Laser-Beam-Steering Subsystem" (NPO-19193) and "More About Beam-Steering Subsystem for Laser Communication" (NPO-19381). Reiterates basic principles of operation of beam-steering subsystem, with emphasis on modes of operation, basic design concepts, and initial experiments on partial prototype of apparatus.

  7. Measurement system with high accuracy for laser beam quality.

    Science.gov (United States)

    Ke, Yi; Zeng, Ciling; Xie, Peiyuan; Jiang, Qingshan; Liang, Ke; Yang, Zhenyu; Zhao, Ming

    2015-05-20

    Presently, most of the laser beam quality measurement system collimates the optical path manually with low efficiency and low repeatability. To solve these problems, this paper proposed a new collimated method to improve the reliability and accuracy of the measurement results. The system accuracy controlled the position of the mirror to change laser beam propagation direction, which can realize the beam perpendicularly incident to the photosurface of camera. The experiment results show that the proposed system has good repeatability and the measuring deviation of M2 factor is less than 0.6%. PMID:26192526

  8. A beam waveguide linearly polarized KU band feed system

    Science.gov (United States)

    Flannery, J. B.

    The linearly polarized KU band beam waveguide feed system considered was designed for use with large Cassegrain antennas typical of those associated with satellite comunications earth stations. The beam waveguide technique permits fixed ground installations of the transmitters and low noise receivers and eliminates the large equipment room usually mounted behind the reflector vertex. The feed system consists of a tapered corrugated wall horn, a matching network, a TE21 mode coupler, three differential phase shifters, a choke coupled rotatable, orthogonal mode transducer, and a servo amplifier system. Attention is given to TE21 mode coupler operation, TE21 mode coupling and directivity, a horn description, a beam wave description, and polarization control.

  9. System for programmable micromachining by means of submicron ion beam

    International Nuclear Information System (INIS)

    A system with submicron ion beam is described. Very bright ion beams are generated by electrohydrodynamic source and are focused in electrostatic ion-optical column. An octupole deflector is used for astigmatism correction and beam deviation. Stabilized power supply of all elements is ensured. Lines of 0.1 μm minimum width are obtained. The micromachining process is controlled by an automated system in CAMAC standard on line with Odrenok computer. Specific features of programmable micromachining and operation of the system in the mode of scanning ion microscope are considered

  10. Simulation studies for ion beam extraction systems

    Energy Technology Data Exchange (ETDEWEB)

    Abdelrahman, M.M.; Zakhary, S.G. [Atomic Energy, Cairo (Egypt). Nuclear Research Center. Accelerators and Ion Sources Dept.], e-mail: moustafa82003@yahoo.com

    2009-06-15

    The characteristics of the ion beam extracted from an ion sources were investigated using computer code SIMION 3 D Version 7.0. It has been used to evaluate the extraction system in order to produce an ion beam with high current and low beam emittance. The results show that the shape of the extraction electrode plays an important role in ion beam formation. Comparison has been made between two extraction systems, Pierce extraction electrode and spherical extraction electrode. The results show that the spherical extraction system yields ion extraction beam with lower emittance and radius than that the Pierce system. The simulation can provide the basis for optimizing the extraction system and the acceleration gap for ion source. (author)

  11. Low energy beam transport system developments

    International Nuclear Information System (INIS)

    For high brightness beam production it is important to preserve the brightness in the low energy beam transport system (LEBT) used to transport and match the ion beams to the next stage of acceleration, usually an RFQ. While electrostatic focusing can be problematic for high current beam transport, reliable electrostatic LEBT operation has been demonstrated with H− beams up to 60 mA. Now, however, it is commonly accepted that an optimal LEBT for high current accelerator applications consists of focusing solenoids with space charge compensation. Two-solenoid LEBTs are successfully used for high current (>100 mA) proton beam transport. Preservation of low emittances (~0.15 π mm-mrad) requires the addition of a heavy gas (Xe, Kr), which causes ~5% of proton loss in a 1 m long LEBT. Similar Xe densities would be required to preserve low emittances of H− beams, but such gas densities cause unacceptably high H− beam losses. A short LEBT with only one short solenoid, movable for RFQ matching, can be used for reduced negative ion stripping. A strong electrostatic-focusing LEBT has been successfully adopted for transport of high current H− beams in the SNS Front End. Some modifications of such electrostatic LEBTs are expected to improve the reliable transport of intense positive and negative ion beams without greatly degrading their low emittances. We concentrate on processes that determine the beam brightness degradation and on their prevention. Proposed improvements to the SNS electrostatic LEBT are discussed

  12. Low energy beam transport system developments

    Science.gov (United States)

    Dudnikov, V.; Han, B.; Stockli, M.; Welton, R.; Dudnikova, G.

    2015-04-01

    For high brightness beam production it is important to preserve the brightness in the low energy beam transport system (LEBT) used to transport and match the ion beams to the next stage of acceleration, usually an RFQ. While electrostatic focusing can be problematic for high current beam transport, reliable electrostatic LEBT operation has been demonstrated with H- beams up to 60 mA. Now, however, it is commonly accepted that an optimal LEBT for high current accelerator applications consists of focusing solenoids with space charge compensation. Two-solenoid LEBTs are successfully used for high current (>100 mA) proton beam transport. Preservation of low emittances (~0.15 π mm-mrad) requires the addition of a heavy gas (Xe, Kr), which causes ~5% of proton loss in a 1 m long LEBT. Similar Xe densities would be required to preserve low emittances of H- beams, but such gas densities cause unacceptably high H- beam losses. A short LEBT with only one short solenoid, movable for RFQ matching, can be used for reduced negative ion stripping. A strong electrostatic-focusing LEBT has been successfully adopted for transport of high current H- beams in the SNS Front End. Some modifications of such electrostatic LEBTs are expected to improve the reliable transport of intense positive and negative ion beams without greatly degrading their low emittances. We concentrate on processes that determine the beam brightness degradation and on their prevention. Proposed improvements to the SNS electrostatic LEBT are discussed.

  13. Gamma beam system at ELI-NP

    Energy Technology Data Exchange (ETDEWEB)

    Ur, Calin Alexandru, E-mail: calin.ur@eli-np.ro [Extreme Light Infrastructure, IFIN-HH, Magurele-Bucharest (Romania)

    2015-02-24

    The Gamma Beam System of ELI-NP will produce brilliant, quasi-monochromatic gamma-ray beams via Inverse Compton Scattering of short laser pulses on relativistic electron beam pulses. The scattered radiation is Doppler upshifted by more than 1,000,000 times and is forward focused in a narrow, polarized, tunable, laser-like beam. The gamma-ray beam at ELI-NP will be characterized by large spectral density of about 10{sup 4} photons/s/eV, narrow bandwidth (< 0.5%) and tunable energy from 200 keV up to about 20 MeV. The Gamma Beam System is a state-of-the-art equipment employing techniques and technologies at the limits of the present-day's knowledge.

  14. THz beam steering by optical coherent control

    CERN Document Server

    Füser, Heiko

    2013-01-01

    We demonstrate optical coherent control of the emission direction of THz radiation. Femtosecond laser pulses are used to excite different types of ultrafast photocurrents along different directions in a bulk GaAs sample. The overall emission pattern can be modified by changing the phase of the optical excitation. With this method, THz beam steering of about 8 degrees is realized. A simple dipole-based model allows us to relate the size of the steering effect to the amplitude ratio between the different photocurrent contributions and to diffraction effects resulting from the excitation spot size.

  15. Progress of beam diagnosis system for EAST neutral beam injector

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Y. J., E-mail: yjxu@ipp.ac.cn; Hu, C. D.; Yu, L.; Liang, L. Z.; Zhang, W. T.; Chen, Y.; Li, X. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China)

    2016-02-15

    Neutral beam injection has been recognized as one of the most effective means for plasma heating. According to the research plan of the EAST physics experiment, two sets of neutral beam injector (NBI) were built and operational in 2014. The paper presents the development of beam diagnosis system for EAST NBI and the latest experiment results obtained on the test-stand and EAST-NBI-1 and 2. The results show that the optimal divergence angle is (0.62°, 1.57°) and the full energy particle is up to 77%. They indicate that EAST NBI work properly and all targets reach or almost reach the design targets. All these lay a solid foundation for the achievement of high quality plasma heating for EAST.

  16. Modified read-out system of the beam phase measurement system for CSNS

    International Nuclear Information System (INIS)

    The customized beam phase measurement system can meet the requirement of beam loss control of the radio-frequency quadrupole (RFQ). However, its read-out part cannot satisfy the requirement of China Spallation Neutron Source (CSNS). CSNS uses the Experimental Physics and Industrial Control System (EPICS) as its control system. So it is necessary to develop the EPICS read-out system consisting of EPICS IOC databases, driver support and OPIs. The new system has been successfully tested in the RFQ. In the future, it will be applied to the beam diagnostics of CSNS. (authors)

  17. Robust Collimation Control of Laser-Generated Ion Beam

    CERN Document Server

    Kawata, S; Kamiyama, D; Nagashima, T; Barada, D; Gu, Y J; Li, X; Yu, Q; Kong, Q; Wang, P X

    2015-01-01

    The robustness of a structured collimation device is discussed for an intense-laser-produced ion beam. In this paper the ion beam collimation is realized by the solid structured collimation device, which produces the transverse electric field; the electric field contributes to reduce the ion beam transverse velocity and collimate the ion beam. Our 2.5 dimensional particle-in cell simulations demonstrate that the collimation device is rather robust against the changes in the laser parameters and the collimation target sizes. The intense short-pulse lasers are now available, and are used to generate an ion beam. The issues in the laser ion acceleration include an ion beam collimation, ion energy spectrum control, ion production efficiency, ion energy control, ion beam bunching, etc. The laser-produced ion beam tends to expand in the transverse and longitudinal directions during the ion beam propagation. The ion beam collimation is focused in this paper.

  18. Beam propagation considerations in the Aurora laser system

    International Nuclear Information System (INIS)

    Aurora is a high-power KrF laser system now being constructed for inertial confinement fusion (ICF) studies. It will use optical angular multiplexing and serial amplification by electron-beam-driven KrF amplifiers to deliver a stacked, multikilojoule 5-ns-duration laser pulse to ICF targets. The requirements of angular multiplexing KrF lasers at the multikilojoule level dictate path lengths on the order of 1 km. The inherent complicated path crossings produced by angular multiplexing and pulse stacking do not allow isolation of individual beam lines, so the optical quality of the long beam paths must be controlled. Propagation of the 248-nm light beams over long paths in air is affected by scattering, absorption thermal gradients and turbulence, beam alignment, and control and optical component figure errors

  19. Controlling Beam Halo-Chaos via Time-Delayed Feedback

    Institute of Scientific and Technical Information of China (English)

    FANG Jin-Qing; WENG Jia-Qiang; ZHU Lun-Wu; LUO Xiao-Shu

    2004-01-01

    The study of controlling high-current proton beam halo-chaos has become a key concerned issue for many important applications. In this paper, time-delayed feedback control method is proposed for beam halo-chaos. Particle in cell simulation results show that the method is very effective and has some advantages for high-current beam experiments and engineering.

  20. Beam Orbit Diagnostics and Control in CANDLE Storage Ring

    CERN Document Server

    Amatuni, Gayane A; Mikaelyan, Raphael; Tsakanov, Vasili M; Vardanyan, Ashot

    2005-01-01

    Stability requirements for the CANDLE light source are the consequence of a small electron beam size and a tolerable photon beam parameters. In a real machine, the components of the storage ring have static and dynamic imperfections, which cause disturbance of the electron beam and consequently photon beams parameters. In the present paper the basic approaches to the beam diagnostics, control and correction issues for the CANDLE facility are given. The algorithms, electronics and processing hardware are described.

  1. Vibrations and stability of complex beam systems

    CERN Document Server

    Stojanović, Vladimir

    2015-01-01

     This book reports on solved problems concerning vibrations and stability of complex beam systems. The complexity of a system is considered from two points of view: the complexity originating from the nature of the structure, in the case of two or more elastically connected beams; and the complexity derived from the dynamic behavior of the system, in the case of a damaged single beam, resulting from the harm done to its simple structure. Furthermore, the book describes the analytical derivation of equations of two or more elastically connected beams, using four different theories (Euler, Rayleigh, Timoshenko and Reddy-Bickford). It also reports on a new, improved p-version of the finite element method for geometrically nonlinear vibrations. The new method provides more accurate approximations of solutions, while also allowing us to analyze geometrically nonlinear vibrations. The book describes the appearance of longitudinal vibrations of damaged clamped-clamped beams as a result of discontinuity (damage). It...

  2. The Fermilab Main Injector: high intensity operation and beam loss control

    CERN Document Server

    Brown, Bruce C; Capista, David; Chou, Weiren; Kourbanis, Ioanis; Morris, Denton K; Seiya, Kiyomi; Wu, Guan Hong; Yang, Ming-Jen

    2013-01-01

    From 2005 through 2012, the Fermilab Main Injector provided intense beams of 120 GeV protons to produce neutrino beams and antiprotons. Hardware improvements in conjunction with improved diagnostics allowed the system to reach sustained operation at ~400 kW beam power. Transmission was very high except for beam lost at or near the 8 GeV injection energy where 95% beam transmission results in about 1.5 kW of beam loss. By minimizing and localizing loss, residual radiation levels fell while beam power was doubled. Lost beam was directed to either the collimation system or to the beam abort. Critical apertures were increased while improved instrumentation allowed optimal use of available apertures. We will summarize the improvements required to achieve high intensity, the impact of various loss control tools and the status and trends in residual radiation in the Main Injector.

  3. Controlling beam halo-chaos via backstepping design

    Institute of Scientific and Technical Information of China (English)

    Gao Yuan; Kong Feng

    2008-01-01

    A backstepping control method is proposed for controlling beam halo-chaos in the periodic focusing channels PFCs) of high-current ion accelerator. The analysis and numerical results show that the method, via adjusting an exterior magnetic field, is effective to control beam halo chaos with five types of initial distribution ion beams, all statistical quantities of the beam halo-chaos are largely reduced, and the uniformity of ion beam is improved. This control method has an important value of application, for the exterior magnetic field can be easily adjusted in the periodical magnetic focusing channels in experiment.

  4. Neutral beam injection system design for KSTAR tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Choi, B.H.; Lee, K.W.; Chung, K.S.; Oh, B.H.; Cho, Y.S.; Bae, Y.D.; Han, J.M. [Korea Atomic Energy Research Institute, Taejon (Korea)

    1998-06-01

    The NBI system for KSTAR (Korean Superconducting Tokamak Advanced Research) has been designed based on conventional positive ion beam technology. One beam line consists of three ion sources, three neutralizers, one bending magnet, and one drift tube. This system will deliver 8 MW deuterium beam to KSTAR plasma in normal operation to support the advanced experiments on heating, current drive and profile control. The key technical issues in this design were high power ion source(120 kV, 65 A), long pulse operation (300 seconds; world record is 30 sec), and beam rotation from vertical to horizontal direction. The suggested important R and D points on ion source and beam line components are also included. (author). 7 refs., 27 figs., 1 tab.

  5. National TLD network for beam calibration quality control in Colombia

    International Nuclear Information System (INIS)

    Full text: Colombia counts now with 16 linear accelerators and 24 cobalt units used for radiation therapy treatments, with a total of 60 radiation beams, and the country takes part in the IAEA/WHO International Network of Postal Dosimetry, as well as in the IAEA/WHO SSDL network. Since the country has technical capacities to develop a national quality control program, based on the SSLD and other dosimetry laboratories, with the support of the IAEA through a coordinated research project, a national network for radiotherapy beam calibration quality control was created. The network is supported by the technical infrastructure of the SSDL and the thermoluminescence dosimetry laboratory of the Nuclear Safety and Radiation Protection Unit of INGEOMINAS and an External Audit Group (EAG) conformed by 5 medical physicists, joined to radiotherapy centers of different regions of the country. The objective of the network is mainly the development of procedures for the evaluation of the beam calibration by means of thermoluminiscent (TL) powdered detectors, through the system of capsules used by the IAEA/WHO postal dosimetry audit program. The TL powder contained in the capsules is divided in 20 mg samples which are placed in metallic minicapsules for their reading. As a result of the work carried out up to now, we have established the procedures for dosimetric evaluation using a HARSHAW 4500 reader. The performance of the system and procedures were evaluated by internal trials using the secondary standard of the SSDL and with irradiation set-ups corresponding to the reference conditions for beam calibration. An uncertainty of the final result better than 2% for evaluation of doses near 2 Gy was obtained. The results of the first dosimetry quality audit exercise to national level, for evaluation of high energy photon beam calibration, are presented. The problems detected, concerning the fill-in of the forms with the information about beam calibration and capsules irradiation

  6. Beam monitor system for high-energy beam transportation at HIMAC

    International Nuclear Information System (INIS)

    Heavy-Ion Medical Accelerator in Chiba (HIMAC) provides ion beams for radiotherapy of cancers and for other basic researches. High-energy beam transport lines deliver the beams to three treatment rooms and two experiment rooms with the aid of 41 beam monitor units. Each monitor unit consists of a wire grid as a profile monitor, or a combined unit in which the wire grid and a parallel plate ionization chamber are united for an additional measurement of a beam intensity. They are operated in a mixed gas of 80% Ar and 20% CO2. The gas gain of the wire grid achieves about 8000 at an applied voltage of -2700 V. Dynamic ranges of the wire gird and the parallel plate ionization chamber were measured to be 8x105 and 1x106 in test using ion beams, respectively. A control system of these monitor units offers easy operation, so that operators are almost free from miss-operations. The monitor units are interlocked with a system which protects patients from the undesired irradiation. Five wire grids are used for continuously monitoring the beam during treatments, which play a role in keeping qualities of the treatments. The monitor system has been designed to meet requirements for medical uses, and works in a stable and reliable manner and satisfies the requirements. (author)

  7. Beam Position and Phase Monitor - Wire Mapping System

    Energy Technology Data Exchange (ETDEWEB)

    Watkins, Heath A [Los Alamos National Laboratory; Shurter, Robert B. [Los Alamos National Laboratory; Gilpatrick, John D. [Los Alamos National Laboratory; Kutac, Vincent G. [Los Alamos National Laboratory; Martinez, Derwin [Los Alamos National Laboratory

    2012-04-10

    The Los Alamos Neutron Science Center (LANSCE) deploys many cylindrical beam position and phase monitors (BPPM) throughout the linac to measure the beam central position, phase and bunched-beam current. Each monitor is calibrated and qualified prior to installation to insure it meets LANSCE requirements. The BPPM wire mapping system is used to map the BPPM electrode offset, sensitivity and higher order coefficients. This system uses a three-axis motion table to position the wire antenna structure within the cavity, simulating the beam excitation of a BPPM at a fundamental frequency of 201.25 MHz. RF signal strength is measured and recorded for the four electrodes as the antenna position is updated. An effort is underway to extend the systems service to the LANSCE facility by replacing obsolete electronic hardware and taking advantage of software enhancements. This paper describes the upgraded wire positioning system's new hardware and software capabilities including its revised antenna structure, motion control interface, RF measurement equipment and Labview software upgrades. The main purpose of the wire mapping system at LANSCE is to characterize the amplitude response versus beam central position of BPPMs before they are installed in the beam line. The wire mapping system is able to simulate a beam using a thin wire and measure the signal response as the wire position is varied within the BPPM aperture.

  8. An automatic beam steering system for the NSLS X-17T beam line using closed orbit feedback

    International Nuclear Information System (INIS)

    Initial observations of motion of the undulator radiation in the NSLS X-17T beam line clearly indicated that the beam had to be stabilized in both directions to be usable for the planned soft X-ray imaging experiments. The low frequency spectra of beam motion contained peaks in the range from dc to 60 Hz and at higher frequencies. A beam steering system employing closed orbit feedback has been designed and installed to stabilize the beam in both planes. In each plane of motion, beam position is measured with a beam position detector and a correction signal is fed back to a local four magnet orbit bump to dynamically control the angle of the radiation at the source. This paper describes the design and performance of the beam steering system

  9. Instrumentation architecture for ITER diagnostic neutral beam power supply system

    International Nuclear Information System (INIS)

    A Neutral Beam (NB) Injection system is used for heating or diagnostics of the plasma in a Tokamak. The Diagnostics Neutral Beam (DNB) system for ITER (International Thermonuclear Experimental Reactor) based on acceleration of negative ions; injects a neutral (H0) beam at 100 KeV with specified modulation into the plasma for charge exchange recombination spectroscopy. DNB Power Supply (DNBPS) system consists of various high voltage power supplies, high current power supplies and RF Generators. The system operates in a given operating sequence; very high electromagnetic transients are intrinsically generated during frequent short circuit at the accelerator grid (breakdowns) and sudden loss of load (Beam off). Instrumentation is to be provided to operate the DNBPS system remotely with required control and protection in synchronisation with ITER operation as directed by CODAC (COntrol Data Access and Communication); the central control system for ITER. Instrumentation functionality includes 1. Operation and control of DNBPS subsystems and associated auxiliaries 2. Protection of DNB components and power supplies using interlock system, 3. To ensure safe operation of high voltage hazardous systems 4. Acquisition of injector performance parameters and 5. To facilitate test and maintenance of individual subsystem. This paper discusses about proposed DNBPS instrumentation architecture. The design generally follows the protocols from the ITER- Plant Control Design Handbook (PCDH). (author)

  10. A beam radiation monitoring and protection system for AGS secondary beams

    International Nuclear Information System (INIS)

    A commercially available radiation monitor using a scintillation detector was modified for charged particle beam monitoring. The device controls access to secondary beams of the AGS and limits beam intensity

  11. Detection systems for radioactive ion beams

    International Nuclear Information System (INIS)

    Two main methods are used to produce radioactive ion beams: -) the ISOL method (isotope separation on-line) in which the stable beam interacts with a thick target, the reaction products diffuse outside the target and are transferred to a source where they are ionized, a mass separator and a post-accelerator drive the selected radioactive ions to the right energy; -) the in-flight fragmentation method in which the stable beam interacts with a thin target, the reaction products are emitted from the target with a restricted angular distribution and a velocity close to that of the incident beam, the experimenter has to take advantage from the reaction kinetics to get the right particle beam. Characteristic time is far longer with the ISOL method but the beam intensity is much better because of the use of a post-accelerator. In both cases, the beam intensity is lower by several orders of magnitude than in the case of a stable beam. This article presents all the constraints imposed by radioactive beams to the detection systems of the reaction products and gives new technical solutions according to the type of nuclear reaction studied. (A.C.)

  12. Beam control and diagnostic functions in the NIF transport spatial filter

    International Nuclear Information System (INIS)

    Beam control and diagnostic systems are required to align the National Ignition Facility (NIF) laser prior to a shot as well as to provide diagnostics on 192 beam lines at shot time. A design that allows each beam's large spatial filter lenses to also serve as objective lenses for beam control and diagnostic sensor packages helps to accomplish the task at a reasonable cost. However, this approach also causes a high concentration of small optics near the pinhole plane of the transport spatial filter (TSF) at the output of each beam. This paper describes the optomechanical design in and near the central vacuum vessel of the TSF

  13. Walking beam pumping unit system efficiency measurements

    International Nuclear Information System (INIS)

    The cost of electricity used by walking beam pumping units is a major expense in producing crude oil. However, only very limited information is available on the efficiency of beam pumping systems and less is known about the efficiency of the various components of the pumping units. This paper presents and discusses measurements that have been made on wells at several Shell locations and on a specially designed walking beam pump test stand at Lufkin Industries. These measurements were made in order to determine the overall system efficiency and efficiency of individual components. The results of this work show that the overall beam pumping system efficiency is normally between 48 and 58 percent. This is primarily dependent on the motor size, motor type, gearbox size, system's age, production, pump size, tubing size, and rod sizes

  14. MEMS-Based Optical Beam Steering System for Quantum Information Processing in 2D Atomic Systems

    OpenAIRE

    Knoernschild, Caleb; Kim, Changsoon; Liu, Bin; Lu, Felix P.; Kim, Jungsang

    2007-01-01

    In order to provide scalability to quantum information processors utilizing trapped atoms or ions as quantum bits (qubits), the capability to address multiple individual qubits in a large array is needed. Micro-electromechanical systems (MEMS) technology can be used to create a flexible and scalable optical system to direct the necessary laser beams to multiple qubit locations. We developed beam steering optics using controllable MEMS mirrors that enable one laser beam to address multiple qub...

  15. A micromechanical beam-steering device for terahertz systems

    OpenAIRE

    Drysdale, T.D.; Cumming, D.R.S.

    2004-01-01

    Beam-steering techniques are required to fully exploit terahertz imaging systems. We propose and model a device employing artificial dielectric techniques to provide a variable phase-control medium. The device consists of two interlocking artificial dielectric surfaces that are initially aligned parallel to each other. By mechanically introducing a relative tilt between the plates, a transmitted wave is subjected to a graded phase delay and thus the beam is steered away from the normal. Conti...

  16. Ultra-precise holographic beam shaping for microscopic quantum control

    Science.gov (United States)

    Zupancic, Philip; Preiss, Philipp M.; Ma, Ruichao; Lukin, Alexander; Eric Tai, M.; Rispoli, Matthew; Islam, Rajibul; Greiner, Markus

    2016-06-01

    High-resolution addressing of individual ultracold atoms, trapped ions or solid state emitters allows for exquisite control in quantum optics experiments. This becomes possible through large aperture magnifying optics that project microscopic light patterns with diffraction limited performance. We use programmable amplitude holograms generated on a digital micromirror device to create arbitrary microscopic beam shapes with full phase and amplitude control. The system self-corrects for aberrations of up to several $\\lambda$ and reduces them to $\\lambda/50$, leading to light patterns with a precision on the $10^{-4}$ level. We demonstrate aberration-compensated beam shaping in an optical lattice experiment and perform single-site addressing in a quantum gas microscope for $^{87}$Rb.

  17. Ultra-precise holographic beam shaping for microscopic quantum control.

    Science.gov (United States)

    Zupancic, Philip; Preiss, Philipp M; Ma, Ruichao; Lukin, Alexander; Eric Tai, M; Rispoli, Matthew; Islam, Rajibul; Greiner, Markus

    2016-06-27

    High-resolution addressing of individual ultracold atoms, trapped ions or solid state emitters allows for exquisite control in quantum optics experiments. This becomes possible through large aperture magnifying optics that project microscopic light patterns with diffraction limited performance. We use programmable amplitude holograms generated on a digital micromirror device to create arbitrary microscopic beam shapes with full phase and amplitude control. The system self-corrects for aberrations of up to several λ and reduces them to λ/50, leading to light patterns with a precision on the 10-4 level. We demonstrate aberration-compensated beam shaping in an optical lattice experiment and perform single-site addressing in a quantum gas microscope for 87Rb. PMID:27410551

  18. Ultra-precise holographic beam shaping for microscopic quantum control

    CERN Document Server

    Zupancic, Philip; Ma, Ruichao; Lukin, Alexander; Tai, M Eric; Rispoli, Matthew; Islam, Rajibul; Greiner, Markus

    2016-01-01

    High-resolution addressing of single ultracold atoms, trapped ions or solid state emitters allows for exquisite control in quantum optics experiments. This becomes possible through large aperture magnifying optics that project microscopic light patterns with diffraction limited performance. We use programmable amplitude holograms generated on a digital micromirror device to create arbitrary microscopic beam shapes with full phase and amplitude control. The system self-corrects for aberrations of up to several $\\lambda$ and reduces them to $\\lambda/50$, leading to light patterns with a precision on the $10^{-4}$ level. We demonstrate aberration-compensated beam shaping in an optical lattice experiment and perform single-site addressing in a quantum gas microscope for $^{87}$Rb.

  19. Low energy beam transport system developments

    Energy Technology Data Exchange (ETDEWEB)

    Dudnikov, V., E-mail: vadim@muonsinc.com [Muons, Inc., Batavia, IL 60510 (United States); Han, B.; Stockli, M.; Welton, R. [ORNL, Oak Ridge, TN 37831 (United States); Dudnikova, G. [University of Maryland, College Park, MD 3261 (United States); Institute of Computational Technologies SBRAS, Novosibirsk (Russian Federation)

    2015-04-08

    For high brightness beam production it is important to preserve the brightness in the low energy beam transport system (LEBT) used to transport and match the ion beams to the next stage of acceleration, usually an RFQ. While electrostatic focusing can be problematic for high current beam transport, reliable electrostatic LEBT operation has been demonstrated with H{sup −} beams up to 60 mA. Now, however, it is commonly accepted that an optimal LEBT for high current accelerator applications consists of focusing solenoids with space charge compensation. Two-solenoid LEBTs are successfully used for high current (>100 mA) proton beam transport. Preservation of low emittances (~0.15 π mm-mrad) requires the addition of a heavy gas (Xe, Kr), which causes ~5% of proton loss in a 1 m long LEBT. Similar Xe densities would be required to preserve low emittances of H{sup −} beams, but such gas densities cause unacceptably high H{sup −} beam losses. A short LEBT with only one short solenoid, movable for RFQ matching, can be used for reduced negative ion stripping. A strong electrostatic-focusing LEBT has been successfully adopted for transport of high current H{sup −} beams in the SNS Front End. Some modifications of such electrostatic LEBTs are expected to improve the reliable transport of intense positive and negative ion beams without greatly degrading their low emittances. We concentrate on processes that determine the beam brightness degradation and on their prevention. Proposed improvements to the SNS electrostatic LEBT are discussed.

  20. Optimal control methods for vertical and horizontal beam dynamics

    International Nuclear Information System (INIS)

    An application of the Macro Fiber Composite (MFC) actuators for damping of a composite beam is presented in this paper. The effectiveness of vibration reduction by a selected control method is tested for vertical and horizontal position of the beam. The original model has been studied numerically by using Galerkin's discretisation method. The numerical results for the vertical and horizontal beams are compared.

  1. Feedback control of optical beam spatial profiles using thermal lensing

    CERN Document Server

    Liu, Zhanwei; Arain, Muzammil A; Williams, Luke; Mueller, Guido; Tanner, David B; Reitze, David H

    2013-01-01

    A method for active control of the spatial profile of a laser beam using adaptive thermal lensing is described. A segmented electrical heater was used to generate thermal gradients across a transmissive optical element, resulting in a controllable thermal lens. The segmented heater also allows the generation of cylindrical lenses, and provides the capability to steer the beam in both horizontal and vertical planes. Using this device as an actuator, a feedback control loop was developed to stabilize the beam size and position.

  2. Design of control system for accelerator

    International Nuclear Information System (INIS)

    Laboratory of Nuclear Science in Tohoku University has made a plan to construct a pulse beam stretcher boostering (STB) the fiscal year from 1995 to 1996. STB has two characteristic functions, one of them is pulse beam stretcher function to change 250 MeV pulse electron beam from Linac to direct current' beam and another is booster ring one to increase from 250 MeV to 1.2 GeV beam. Today, the detailed design is going to proceed. The subjects of control system are the direct current electromagnet, the pulse electromagnet, RF system, the vacuum system, the beam monitor system, the triggered system and the inter rock system. We will construct a control program of our own making. Another characteristic function is to adopt the directional object data base. The construction of hardware and software and the future planning are explained. (S.Y.)

  3. Adaptive-robust Control of a Smart Beam with Support Excitation Using Piezoelectric Layers

    Directory of Open Access Journals (Sweden)

    Mohammad Azadi

    2013-04-01

    Full Text Available In this paper, vibrations of a beam with support excitation and a tip mass are suppressed using piezoelectric layers. The beam is fixed to a motion support from one end and the other end is free with an attached mass. The beam is considered as an Euler-Bernoulli beam. The governing equations of motion are derived based on the generalized function theory and Lagrange-Rayleigh-Ritz technique. An adaptive-robust control scheme is applied to control the vibrations of the beam. The mathematical modelling of the beam with control algorithm is derived and in purpose to study the effect of the amount of tip mass, size and location of the piezoelectric layers and the type of the support excitation on the beam vibrations, the system is simulated. Finally, the results of simulation are presented.

  4. Constrained modes in control theory - Transmission zeros of uniform beams

    Science.gov (United States)

    Williams, T.

    1992-01-01

    Mathematical arguments are presented demonstrating that the well-established control system concept of the transmission zero is very closely related to the structural concept of the constrained mode. It is shown that the transmission zeros of a flexible structure form a set of constrained natural frequencies for it, with the constraints depending explicitly on the locations and the types of sensors and actuators used for control. Based on this formulation, an algorithm is derived and used to produce dimensionless plots of the zero of a uniform beam with a compatible sensor/actuator pair.

  5. Active vibration control of clamped beams using positive position feedback controllers with moment pair

    International Nuclear Information System (INIS)

    This paper investigates the active vibration control of clamp beams using positive position feedback (PPF) controllers with a sensor/ moment pair actuator. The sensor/moment pair actuator which is the non-collocated configuration leads to instability of the control system when using the direct velocity feedback (DVFB) control. To alleviate the instability problem, a PPF controller is considered in this paper. A parametric study of the control system with PPF controller is first conducted to characterize the effects of the design parameters (gain and damping ratio in this paper) on the stability and performance. The gain of the controller is found to affect only the relative stability. Increasing the damping ratio of the controller slightly improves the stability condition while the performance gets worse. In addition, the higher mode tuned PPF controller affects the system response at the lower modes significantly. Based on the characteristics of PPF controllers, a multi-mode controllable SISO PPF controller is then considered and tuned to different modes (in this case, three lowest modes) numerically and experimentally. The multi-mode PPF controller can be achieved to have a high gain margin. Moreover, it reduces the vibration of the beam significantly. The vibration levels at the tuned modes are reduced by about 11 dB

  6. A simple electron-beam lithography system

    DEFF Research Database (Denmark)

    Mølhave, Kristian; Madsen, Dorte Nørgaard; Bøggild, Peter

    2005-01-01

    A large number of applications of electron-beam lithography (EBL) systems in nanotechnology have been demonstrated in recent years. In this paper we present a simple and general-purpose EBL system constructed by insertion of an electrostatic deflector plate system at the electron-beam exit of the...... column of a scanning electron microscope (SEM). The system can easily be mounted on most standard SEM systems. The tested setup allows an area of up to about 50 x 50 pm to be scanned, if the upper limit for acceptable reduction of the SEM resolution is set to 10 run. We demonstrate how the EBL system can...... be used to write three-dimensional nanostructures by electron-beam deposition. (C) 2004 Elsevier B.V. All rights reserved....

  7. New control techniques for extraction of bevalac beams

    International Nuclear Information System (INIS)

    Beams of accelerated heavy ions can now be delivered as one-second-long dc pulses with minimal fluctuations in instantaneous flux. Pulse duration can be held constant to within 1% while keeping a high non-varying extraction efficiency which minimizes pulse-to-pulse position shift in the extracted beam. In addition, differing beam intensities over several orders of magnitude can be delivered. Computer adjustment of all measurement and control devices results in linear operation over three orders of magnitude of beam intensity. Control of beam structure is accomplished by a unique combination of dual slope integrators and phase forward ''predictive'' circuits in the feedback loop

  8. Fast beam steering with full polarization control using a galvanometric optical scanner and polarization controller

    CERN Document Server

    Jofre, M; Steinlechner, F; Oliverio, N; Torres, J P; Pruneri, V; Mitchell, M W; 10.1364/OE.20.012247

    2012-01-01

    Optical beam steering is a key element in many industrial and scientific applications like in material processing, information technologies, medical imaging and laser display. Even though galvanometer-based scanners offer flexibility, speed and accuracy at a relatively low cost, they still lack the necessary control over the polarization required for certain applications. We report on the development of a polarization steerable system assembled with a fiber polarization controller and a galvanometric scanner, both controlled by a digital signal processor board. The system implements control of the polarization decoupled from the pointing direction through a feed-forward control scheme. This enables to direct optical beams to a desired direction without affecting its initial polarization state. When considering the full working field of view, we are able to compensate polarization angle errors larger than 0.2 rad, in a temporal window of less than $\\sim 20$ ms. Given the unification of components to fully cont...

  9. Development of KOMAC Beam Monitoring System Using EPICS

    International Nuclear Information System (INIS)

    The beam loss signals must be digitized and the sampling has to be synchronized to a reference signal which is an external trigger for beam operation. The digitized data must be accessible by the Experimental Physics and Industrial Control System (EPICS)-based control system, which manages the whole accelerator control. In order to satisfy the requirement, an Input /Output Controller (IOC), which runs Linux on a CPU module with PCI express based Analog to Digital Converter (ADC) modules, has been adopted. An associated linux driver and EPICS device support module also have been developed. The IOC meets the requirements and the development and maintenance of the software for the IOC is considerably efficient. The data acquisition system running EPICS will be used in increasing phase of KOrea Multi-purpose Accelerator Complex (KOMAC) beam power. The beam monitoring system integrates BLM and BPM signals into control system and offers real-time data to operators. The IOC, which is implemented with Linux and PCI driver, has supported data acquisition as a very flexible solution

  10. Development of KOMAC Beam Monitoring System Using EPICS

    Energy Technology Data Exchange (ETDEWEB)

    Song, Young-Gi; Yun, Sang-Pil; Kim, Han-Sung; Kwon, Hyeok-Jung; Cho, Yong-Sub [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-10-15

    The beam loss signals must be digitized and the sampling has to be synchronized to a reference signal which is an external trigger for beam operation. The digitized data must be accessible by the Experimental Physics and Industrial Control System (EPICS)-based control system, which manages the whole accelerator control. In order to satisfy the requirement, an Input /Output Controller (IOC), which runs Linux on a CPU module with PCI express based Analog to Digital Converter (ADC) modules, has been adopted. An associated linux driver and EPICS device support module also have been developed. The IOC meets the requirements and the development and maintenance of the software for the IOC is considerably efficient. The data acquisition system running EPICS will be used in increasing phase of KOrea Multi-purpose Accelerator Complex (KOMAC) beam power. The beam monitoring system integrates BLM and BPM signals into control system and offers real-time data to operators. The IOC, which is implemented with Linux and PCI driver, has supported data acquisition as a very flexible solution.

  11. Active Vibration Control of Elastic Beam by Means of Shape Memory Alloy Layers

    Science.gov (United States)

    Chen, Q.; Levy, C.

    1996-01-01

    The mathematical model of a flexible beam covered with shape memory alloy (SMA) layers is presented. The SMA layers are used as actuators, which are capable of changing their elastic modulus and recovery stress, thus changing the natural frequency of, and adjusting the excitation to, the vibrating beam. The frequency factor variation as a function of SMA Young's modulus, SMA layer thickness and beam thickness is discussed. Also control of the beam employing an optimal linear control law is evaluated. The control results indicate how the system reacts to various levels of excitation input through the non-homogeneous recovery shear term of the governing differential equation.

  12. The ATLAS Detector Control System

    Science.gov (United States)

    Lantzsch, K.; Arfaoui, S.; Franz, S.; Gutzwiller, O.; Schlenker, S.; Tsarouchas, C. A.; Mindur, B.; Hartert, J.; Zimmermann, S.; Talyshev, A.; Oliveira Damazio, D.; Poblaguev, A.; Braun, H.; Hirschbuehl, D.; Kersten, S.; Martin, T.; Thompson, P. D.; Caforio, D.; Sbarra, C.; Hoffmann, D.; Nemecek, S.; Robichaud-Veronneau, A.; Wynne, B.; Banas, E.; Hajduk, Z.; Olszowska, J.; Stanecka, E.; Bindi, M.; Polini, A.; Deliyergiyev, M.; Mandic, I.; Ertel, E.; Marques Vinagre, F.; Ribeiro, G.; Santos, H. F.; Barillari, T.; Habring, J.; Huber, J.; Arabidze, G.; Boterenbrood, H.; Hart, R.; Iakovidis, G.; Karakostas, K.; Leontsinis, S.; Mountricha, E.; Ntekas, K.; Filimonov, V.; Khomutnikov, V.; Kovalenko, S.; Grassi, V.; Mitrevski, J.; Phillips, P.; Chekulaev, S.; D'Auria, S.; Nagai, K.; Tartarelli, G. F.; Aielli, G.; Marchese, F.; Lafarguette, P.; Brenner, R.

    2012-12-01

    The ATLAS experiment is one of the multi-purpose experiments at the Large Hadron Collider (LHC) at CERN, constructed to study elementary particle interactions in collisions of high-energy proton beams. Twelve different sub detectors as well as the common experimental infrastructure are controlled and monitored by the Detector Control System (DCS) using a highly distributed system of 140 server machines running the industrial SCADA product PVSS. Higher level control system layers allow for automatic control procedures, efficient error recognition and handling, manage the communication with external systems such as the LHC controls, and provide a synchronization mechanism with the ATLAS data acquisition system. Different databases are used to store the online parameters of the experiment, replicate a subset used for physics reconstruction, and store the configuration parameters of the systems. This contribution describes the computing architecture and software tools to handle this complex and highly interconnected control system.

  13. [Advanced development of particle beam probe diagnostic system

    International Nuclear Information System (INIS)

    This progress report under DOE Grant DE-FG02-85ER3211 covers the period 15 December 1992 through 15 October 1993. The major accomplishments of this period are summarized below: The basic TEXT heavy ion beam probe including the primary beam line, the upper secondary beam line with the old 500 keV analyzer, and the lower secondary beam line with the new 2 MeV analyzer is operational and system shake-down is now beginning. Several subsystems of the complete system design are still under development, including secondary beam line sweeps, primary beam detectors, the digital control and data acquisition system. The lower analyzer entrance aperture and detector plates also have very limited capabilities to make it possible to more rapidly obtain satisfactory initial alignment and calibration conditions. We have performed a variety of high voltage tests that establish the basic efficacy of the 2 MeV analyzer design. We have upgraded the ion optics and added vacuum chambers in our vertical test stand facility to allow us to test the 2 MeV analyzers. We have also constructed a facility for testing ion source characteristics. We analyzed data on primary beam modulation taken during the last run period and confirmed the accuracy of our simulation code. Analysis of magnetic field measurements continued

  14. Construction of ion beam pulse radiolysis system

    Energy Technology Data Exchange (ETDEWEB)

    Chitose, Norihisa; Katsumura, Yosuke; Domae, Masafumi; Ishigure, Kenkichi; Murakami, Takeshi [Tokyo Univ. (Japan)

    1996-10-01

    An ion beam pulse radiolysis system has been constructed at HIMAC facility. Ion beam of 24 MeV He{sup 2+} with the duration longer than 1 {mu}s is available for irradiation. Three kinds of aqueous solutions, (C{sub 6}H{sub 5}){sub 2}CO, NaHCO{sub 3} and KSCN, were irradiated and the absorption signals were observed. (author)

  15. Research on automatic correction of electronic beam path for distributed control

    International Nuclear Information System (INIS)

    Background: Dynamitron, an electron irradiation accelerator of high-voltage, is used as a radiation source for industrial and agricultural production. The control system is an important component of dynamitron. Purpose: The aim is to improve the control system to meet the performance requirements of dynamitron for the stability. Methods: A distributed control system for the 1.5-MeV dynamitron is proposed to gain better performance. On this basis, an electron beam trajectory automatic correction method based on Cerebellar Model Articulation Controller and Proportional-Integral Derivative (CMAC-PID) controller is designed to improve the function of electron beam extraction system. Results: The distributed control system can meet the control requirements of the accelerator. The stability of the CMAC PID controller is better than that of conventional PID controller for the electron beam trajectory automatic correction system, and hence the CMAC-PID controller can provide better protection of dynamitron when electron beam deflection occurs. Conclusion: The distributed control system and the electron beam trajectory automatic correction method system can effectively improve the performance and reduce the failure probability of the accelerator, thereby enhancing the efficiency of the accelerator. (authors)

  16. ADAPTIVE CONTROL OF FLEXIBLE BEAM WITH UNKNOWN DEAD-ZONE IN THE DRIVING MOTOR

    Institute of Scientific and Technical Information of China (English)

    Wang Xingsong; Hong Henry; Su Chunyi

    2004-01-01

    Adaptive control of a flexible beam system preceded by an unknown dead-zone in the driving motor is investigated in state space form. By introducing an important lemma for simplifying error equation between the flexible beam model and the matching reference model, a robust adaptive control scheme is developed by involving the dead-zone inverse terms. The new adaptive control law ensures global stability of the entire system and achieves desired tracking precision even when the slopes of the dead-zone are not equal. Simulations performed on a typical flexible beam system illustrate and clarify the validity of this approach.

  17. Controllable Airy-like beams induced by tunable phase patterns

    Science.gov (United States)

    Li, D.; Qian, Y.

    2016-01-01

    We propose and experimentally observe a novel family of Airy-like beams. First, we theoretically investigate the physical generation of our proposed controllable Airy-like beams by introducing a rotation angle factor into the phase function, which can regulate and flexibly control the beam wavefront. Meanwhile we can also readily control the main lobes of these beams to follow appointed parabolic trajectories using the rotation angle factor. We also demonstrate that the controllable Airy-like beams lack the properties of being diffraction-free and self-healing. The experiments are performed and the results are in accord with the theoretical simulations. We believe that the intriguing characteristics of our proposed Airy-like beams could provide more degrees of freedom, and are likely to give rise to new applications and lend versatility to the emerging field.

  18. Nova laser alignment control system

    International Nuclear Information System (INIS)

    Alignment of the Nova laser requires control of hundreds of optical components in the ten beam paths. Extensive application of computer technology makes daily alignment practical. The control system is designed in a manner which provides both centralized and local manual operator controls integrated with automatic closed loop alignment. Menudriven operator consoles using high resolution color graphics displays overlaid with transport touch panels allow laser personnel to interact efficiently with the computer system. Automatic alignment is accomplished by using image analysis techniques to determine beam references points from video images acquired along the laser chain. A major goal of the design is to contribute substantially to rapid experimental turnaround and consistent alignment results. This paper describes the computer-based control structure and the software methods developed for aligning this large laser system

  19. Beam monitor system for high-energy beam transportation at HIMAC

    CERN Document Server

    Torikoshi, M; Takada, E; Kanai, T; Yamada, S; Ogawa, H; Okumura, K; Narita, K; Ueda, K; Mizobata, M

    1999-01-01

    Heavy-Ion Medical Accelerator in Chiba (HIMAC) provides ion beams for radiotherapy of cancers and for other basic researches. High-energy beam transport lines deliver the beams to three treatment rooms and two experiment rooms with the aid of 41 beam monitor units. Each monitor unit consists of a wire grid as a profile monitor, or a combined unit in which the wire grid and a parallel plate ionization chamber are united for an additional measurement of a beam intensity. They are operated in a mixed gas of 80% Ar and 20% CO sub 2. The gas gain of the wire grid achieves about 8000 at an applied voltage of -2700 V. Dynamic ranges of the wire gird and the parallel plate ionization chamber were measured to be 8x10 sup 5 and 1x10 sup 6 in test using ion beams, respectively. A control system of these monitor units offers easy operation, so that operators are almost free from miss-operations. The monitor units are interlocked with a system which protects patients from the undesired irradiation. Five wire grids are use...

  20. The AGS Booster Beam Position Monitor system

    International Nuclear Information System (INIS)

    To accelerate both protons and heavy ions, the AGS Booster requires a broadband (multi-octave) beam position monitoring system with a dynamic range spanning several orders of magnitude (2 x 1010 to 1.5 x 1013 particles per pulse). System requirements include the ability to acquire single turn trajectory and average orbit information with ± 0.1 mm resolution. The design goal of ± 0.5 mm corrected accuracy requires that the detectors have repeatable linear performance after periodic bakeout at 300 degree C. The system design and capabilities of the Booster Beam Position Monitor will be described, and initial results presented. 7 refs., 5 figs

  1. ROBUST POSITIONING OF LASER BEAMS USING PROPORTIONAL INTEGRAL DERIVATIVE AND BASED OBSERVER-FEEDBACK CONTROL

    Directory of Open Access Journals (Sweden)

    Kwabena A. Konadu

    2013-01-01

    Full Text Available High-precision positioning of laser beams has been a great challenge in industry due to inevitable existence of noise and disturbance. The work presented in this study addresses this problem by employing two different control strategies: Proportional Integral Derivative (PID control and state feedback control with an observer. The control strategies are intended to stabilize the position of a laser beam on a Position Sensing Device (PSD located on a Laser Beam Stabilization (or, laser beam system system. The laser beam system consists of a laser source, a Fast Steering Mirror (FSM, a PSD and a vibrating platform to generate active disturbance. The traditional PID controller is widely used in industry due to its satisfactory performance, various available tuning methods and relatively straightforward design processes. However, design of filters to obtain the derivative signal is challenging and can unexpectedly distort the dynamics of the system being controlled. As an alternative, use of an Observer-Based State Feedback (OBSF method is proposed and implemented. The state-space model of the laser beam system is utilized and an observer is applied to estimate the state of the system, since all the state variables cannot be measured directly. For observer design, eigenvalue assignment and optimal design methods are used and compared in terms of system performance. Also a comparative analysis between the PID and OBSF controllers is provided. Simulations and experimental results show that the OBSF controller rejects disturbance better and has a simpler design procedure.

  2. Distributed control system for LEHIPA

    International Nuclear Information System (INIS)

    Accelerator Driven System (ADS) has spurred tremendous interest in developing high intensity proton accelerator and set challenging demands in terms of developing high current and high intensity proton accelerator. LEHIPA is the the first stage in the development of ADS purpose and portable (MS/ Windows and LINUX) Operator Interface for Low Energy High Intensity Proton Accelerator (LEHIPA) is designed and developed. This operator interface is already deployed in the field for control of Low Energy Beam Tube section of the LEHIPA. This paper discusses the salient points and features of the operator interface for LEHIPA. LEHIPA will have several subsystems. All subsystems will have their respective control and instrumentation system with required protection. All subsystems will be connected to a centralized control system. To meet the the requirement of phased development and various sub system integration the control system is a distributed system. The paper will describe the distributed control systems features and selected architecture for LEHIPA. (author)

  3. Control of Beam Halo-Chaos Based on Self-Field-Intensity of Particle Beam

    Institute of Scientific and Technical Information of China (English)

    YU Hai-Jun; BAI Long; WENG Jia-Qiang; LUO Xiao-Shu

    2008-01-01

    @@ The KV beam through an axisymmetric periodic-focusing magnetic field is studied using the particle-core model.A new variable of the self-field-intensity of particle beam is selected,and an idea of self-field feedback controller is proposed based on the variable for controlling the halo-chaos.We perform multiparticle simulation to control the halo by using the self-field feedback controller.

  4. Minimal requirements for quality controls in radiotherapy with external beams

    International Nuclear Information System (INIS)

    Physical dosimetric guidelines have been developed by the Italian National Institute of Health study group on quality assurance in radiotherapy to define protocols for quality controls in external beam radiotherapy. While the document does not determine strict rules or firm recommendations, it suggests minimal requirements for quality controls necessary to guarantee an adequate degree of accuracy in external beam radiotherapy

  5. Upgrading of the beam diagnostic system of U-70 beam transfer lines

    CERN Document Server

    Kovaltsov, V I; Matyushin, A T; Milyutkin, V; Romanov, I; Seleznev, V; Sytin, A N; Clausen, M

    2001-01-01

    The beam diagnostic system of U-70 beam transfer lines (beam profiles, intensity and beam losses measurements) was designed in the beginning of 80-th on the base of 8-bit microprocessor, SUMMA hardware and home made serial communication link. Because of the maintenance problems the decision was taken to upgrade the hardware and software parts of the system.

  6. Fast beam steering with full polarization control using a galvanometric optical scanner and polarization controller

    OpenAIRE

    Jofre M.; Anzolin G.; Steinlechner F.; Oliverio N.; Torres J. P.; Pruneri V.; Mitchell M.W.

    2012-01-01

    Optical beam steering is a key element in many industrial and scientific applications like in material processing, information technologies, medical imaging and laser display. Even though galvanometer-based scanners offer flexibility, speed and accuracy at a relatively low cost, they still lack the necessary control over the polarization required for certain applications. We report on the development of a polarization steerable system assembled with a fiber polarization controller and a galva...

  7. Robotics Methods for Beam Line Instrument Simulation and Control

    International Nuclear Information System (INIS)

    The majority of sample positioning systems in use at neutron and synchrotron beam line facilities around the world, may be accurately described as serial robot manipulators, i.e. they comprise a series of rotating or translating links connected together in a chain, with the tool or sample that is to be manipulated attached to one end. This characterization suggests that the methods of serial robot kinematic modeling might be usefully applied to the task of simulating and controlling beam line positioning systems. We describe how this approach is being developed within the planning, simulation and control software, SScanSS. The advantages of using the robotics approach are shown to include the ability to: (1) model any number of disparate positioning systems from within one software (and hence one user interface), with a minimum of instrument specific code, (2) accurately and speedily position and orientate samples of arbitrary complexity, and (3) provide options for automatically optimizing other important experimental parameters, such as the measurement count time. The possible extension of this technique to include parallel robotic systems, such as Stewart Platforms, is also discussed

  8. Beam developments for the Harwell microprobe system

    International Nuclear Information System (INIS)

    A consequence of the rapid development of micron and submicron size electronic devices is the diminished applicability of high energy ion microprobes with their present resolution limitations to the study of such components. Although submicron beams have been reported the available beam current is barely sufficiently for PIXE and is not adequate for RBS. This lack of lateral resolution is due to low beam brightness at the microprobe object and aberrations in the focussing elements. As part of a program to address these problems the Harwell microprobe lens has been relocated on a new 5 MV Laddertron accelerator. The increased brightness and improved stability of this facility has so far led to a reduction in beam size from 3x3 μm2 to about 2x2 μm2. The feasibility of using a liquid metal ion source has been examined with a view to achieving more substantial increases in brightness. While such sources have brightness approximately 105 times greater than conventional gaseous sources the highly divergent nature of the beam presents problems for the beam transport system. The use of a liquid metal source on the accelerator has been successfully demonstrated but it indicates the need for a special low aberration injection lens if brightness is to be maintained. (orig.)

  9. Beam developments for the Harwell microprobe system

    International Nuclear Information System (INIS)

    A consequence of the rapid development of micron and submicron size electronic devices is the diminished applicability of high energy ion microprobes with their present resolution limitations to the study of such components. Although submicron beams have been reported the available beam current is barely sufficiently for PIXE and is not adequate for RBS. This lack of lateral resolution is due to low beam brightness at the microprobe object and aberrations in the focusing elements. As part of a program to address these problems the Harwell microprobe lens has been relocated on a new 5 MV Laddertron accelerator. The increased brightness and improved stability of this facility has so far led to a reduction in beam size from 3 x 3 μm2 to about 2 x 2 μm2. The feasibility of using a liquid metal ion source has been examined with a view to achieving more substantial increases in brightness. While such sources have brightness approximately 105 times greater than conventional gaseous sources the highly divergent nature of the beam presents problems for the beam transport system. The use of a liquid metal source on the accelerator has been successfully demonstrated but it indicates the need for a special low aberration injection lens if brightness is to be maintained

  10. Acoustic beam control in biomimetic projector via velocity gradient

    Science.gov (United States)

    Gao, Xiaowei; Zhang, Yu; Cao, Wenwu; Dong, Erqian; Song, Zhongchang; Li, Songhai; Tang, Liguo; Zhang, Sai

    2016-07-01

    A biomimetic projector (BioP) based on computerized tomography of pygmy sperm whale's biosonar system has been designed using gradient-index (GRIN) material. The directivity of this BioP device was investigated as function of frequency and the velocity gradient of the GRIN material. A strong beam control over a broad bandwidth at the subwavelength scale has been achieved. Compared with a bare subwavelength source, the main lobe pressure of the BioP is about five times as high and the angular resolution is one order of magnitude better. Our results indicate that this BioP has excellent application potential in miniaturized underwater sonars.

  11. The AGS Booster beam loss monitor system

    International Nuclear Information System (INIS)

    A beam loss monitor system has been developed for the Brookhaven National Laboratory Booster accelerator, and is designed for use with intensities of up to 1.5 x 1013 protons and carbon to gold ions at 50-3 x 109 ions per pulse. This system is a significant advance over the present AGS system by improving the sensitivity, dynamic range, and data acquisition. In addition to the large dynamic range achievable, it is adaptively shifted when high losses are detected. The system uses up to 80 argon filled ion chambers as detectors, as well as newly designed electronics for processing and digitizing detector outputs. The hardware simultaneously integrates each detector output, interfaces to the beam interrupt systems, and digitizes all 80 channels to 21 bits at 170 KHz. This paper discuses the design, construction, and operation of the system. 4 refs., 2 figs

  12. Beam loss monitor system for the SSC

    International Nuclear Information System (INIS)

    At full intensity the energy contained in each beam of the Superconducting Super Collider (SSC) is 400 MJ. The loss of a small fraction of that beam has the potential to cause magnet quenches or even severe damage to Collider components. To help protect the machine a sensitive and reliable beam loss monitor (BLM) system must be designed and built. In fact, BLM systems will be needed for all the accelerators of the SSC. The BLM system requirements for each of these accelerators will be discussed, but emphasis will be placed on the Collider. The discussion will include the preliminary design of BLM systems, the considerations that led to these designs, the calculations that were performed in development of the designs, and the problems that remain to be solved. A major tool in the design process has been a series of Monte Carlo calculations that were used to estimate beam loss distributions for the Collider arcs, the interaction regions, and the west utility region. These calculations were also used to study the fluence as a function of energy, the particle content, and the dose rate at selected positions. Detailed considerations such as detector spacing and sensitivity, loss fluctuations, reliability, and maintainability will be discussed. The proposed preliminary BLM system design for the Collider uses a radiation-hard, solid-state ionization detector and fast analog-to-digital conversion. Details of this design and relevant options will be discussed

  13. The Utrecht 850 kV cascade generator I. Beam deflection and energy control

    NARCIS (Netherlands)

    Braams, C.M.; Smith, P.B.

    1960-01-01

    The beam deflection magnet and energy control system of the Utrecht cascade generator are described. The uniform-field magnet has entrance and exit slits located outside the magnetic held. Since the cascade generator produces a vertical beam, the most convenient choice for the angle of deflection wa

  14. Design and testing of a hybrid polymeric electrostrictive/piezoelectric beam with bang bang control

    Science.gov (United States)

    Tzou, H. S.; Chai, W. K.

    2007-01-01

    Electrostrictive materials, hard ceramics and soft polymers, have been used as precision actuators in many engineering applications. This study is to examine bang-bang control performance of a hybrid Plexiglas beam laminated with polymeric electrostrictive (RTV 270) actuator and piezoelectric polyvinylidene fluoride (PVDF) sensor layers using both analytical and experimental techniques. Material characteristics are calibrated via static testing first; a hybrid beam model is then fabricated and an experiment set-up, consisting of a bang-bang controller, high-voltage amplifier, data acquisition system and the hybrid beam system, is designed to evaluate vibration control characteristics (i.e., damping ratio estimation) of the hybrid beam subjected to various control conditions. Due to the quadratic behaviour of electrostrictive materials, the controller activates the electrostrictive actuator only in upward motion of the beam, with reference to signals generated from the piezoelectric sensor. Base on constitutive equations and dynamic/control characteristics, a mathematic hybrid beam model is also derived from the electrostrictive thin shell theory and its dynamic responses, based on the finite difference discretization, are simulated to predict damping ratios resulting from control forces induced by the electrostrictive actuators. Dynamic responses (with and without control) of the physical beam model are measured and compared with simulation results. Favourable comparison suggests that the mathematical model describes the experimental model very well and its application to other advanced structures can be proceeded.

  15. ISR internal beam-dumping system

    CERN Multimedia

    1970-01-01

    Parts of the internal beam-dumping system. In the ring on the right are shown the four tanks containing the vertically deflecting magnets and in the ring on the left is the absorber block. Identical parts are on opposite sides in the other half of this intersection region.

  16. Systems analysis on laser beamed power

    Science.gov (United States)

    Zeiders, Glenn W., Jr.

    1993-01-01

    The NASA SELENE power beaming program is intended to supply cost-effective power to space assets via Earth-based lasers and active optics systems. Key elements of the program are analyzed, the overall effort is reviewed, and recommendations are presented.

  17. Beam spill control with frequency modulation in electron synchrotron

    International Nuclear Information System (INIS)

    The new method has been applied to the beam spill control of the INS electron synchrotron. In this method, the RF operating frequency is slowly increased at the final stage of the accelerating period. Then the equilibrium orbit shrinks and the beam hits the radiator gradually, staying in the stable phase. The new method gives the uniform beam spill in the energy region below 700 MeV where the old method has not been successful enough. (author)

  18. Configuration and Validation of the LHC Beam Loss Monitoring System

    CERN Document Server

    Zamantzas, C; Emery, J; Fitzek, J; Follin, F; Jackson, S; Kain, V; Kruk, G; Misiowiec, M; Roderick, C; Sapinski, M

    2009-01-01

    The LHC Beam Loss Monitoring (BLM) system is one of the most complex instrumentation systems deployed in the LHC. As well as protecting the machine, the system is also used as a means of diagnosing machine faults, and providing feedback of losses to the control room and several systems such as the Collimation, the Beam Dump and the Post-Mortem. The system has to transmit and process signals from over 4’000 monitors, and has approaching 3 million configurable parameters. This paper describes the types of configuration data needed, the means used to store and deploy all the parameters in such a distributed system and how operators are able to alter the operating parameters of the system, particularly with regard to the loss threshold values. The various security mechanisms put in place, both at the hardware and software level, to avoid accidental or malicious modification of these BLM parameters are also shown for each case.

  19. Development of beam flattening system using non-linear beam optics at J-PARC/JSNS

    International Nuclear Information System (INIS)

    As increasing in the beam power, the damage of the target becomes serious. Especially for a target for high power short pulse spallation neutron source, the damage due to the proton beam on the target vessel for liquid metal target such as mercury is reported to be proportional of 4th power of the peak intensity of the proton beam. Reduction of the peak intensity is important for the beam injection system. At the JSNS, beam profile can be described by the clear Gaussian functions. To reduce peak intensity, we have developed a beam transport system by non-linear beam optics using octupole magnets. (author)

  20. Ion beam pulse radiolysis system at HIMAC

    Energy Technology Data Exchange (ETDEWEB)

    Chitose, N.; Katsumura, Y.; Domae, M.; Ishigure, K. [Tokyo Univ. (Japan); Murakami, T.

    1997-03-01

    An ion beam pulse radiolysis system has been constructed at HIMAC facility. Ion beam of 24MeV He{sup 2+} with the duration longer than 1 {mu}s is available for irradiation. Three kinds of aqueous solutions, (C{sub 6}H{sub 5}){sub 2}CO, NaHCO{sub 3}, and KSCN, were irradiated and the absorption signals corresponding to (C{sub 6}H{sub 5}){sub 2}CO{sup -}, CO{sub 3}{sup -}, and (SCN){sub 2}{sup -} respectively were observed. Ghost signals which interfere with the measurement are also discussed. (author)

  1. CRionScan: A stand-alone real time controller designed to perform ion beam imaging, dose controlled irradiation and proton beam writing

    International Nuclear Information System (INIS)

    High resolution ion microbeams, usually used to perform elemental mapping, low dose targeted irradiation or ion beam lithography needs a very flexible beam control system. For this purpose, we have developed a dedicated system (called “CRionScan”), on the AIFIRA facility (Applications Interdisciplinaires des Faisceaux d’Ions en Région Aquitaine). It consists of a stand-alone real-time scanning and imaging instrument based on a Compact Reconfigurable Input/Output (Compact RIO) device from National Instruments™. It is based on a real-time controller, a Field Programmable Gate Array (FPGA), input/output modules and Ethernet connectivity. We have implemented a fast and deterministic beam scanning system interfaced with our commercial data acquisition system without any hardware development. CRionScan is built under LabVIEW™ and has been used on AIFIRA’s nanobeam line since 2009 (Barberet et al., 2009, 2011) [1,2]. A Graphical User Interface (GUI) embedded in the Compact RIO as a web page is used to control the scanning parameters. In addition, a fast electrostatic beam blanking trigger has been included in the FPGA and high speed counters (15 MHz) have been implemented to perform dose controlled irradiation and on-line images on the GUI. Analog to Digital converters are used for the beam current measurement and in the near future for secondary electrons imaging. Other functionalities have been integrated in this controller like LED lighting using Pulse Width Modulation and a “NIM Wilkinson ADC” data acquisition

  2. The CMS Beam Halo Monitor Detector System

    CERN Document Server

    CMS Collaboration

    2015-01-01

    A new Beam Halo Monitor (BHM) detector system has been installed in the CMS cavern to measure the machine-induced background (MIB) from the LHC. This background originates from interactions of the LHC beam halo with the final set of collimators before the CMS experiment and from beam gas interactions. The BHM detector uses the directional nature of Cherenkov radiation and event timing to select particles coming from the direction of the beam and to suppress those originating from the interaction point. It consists of 40 quartz rods, placed on each side of the CMS detector, coupled to UV sensitive PMTs. For each bunch crossing the PMT signal is digitized by a charge integrating ASIC and the arrival time of the signal is recorded. The data are processed in real time to yield a precise measurement of per-bunch-crossing background rate. This measurement is made available to CMS and the LHC, to provide real-time feedback on the beam quality and to improve the efficiency of data taking. In this talk we will describ...

  3. The CMS Beam Halo Monitor Detector System

    CERN Document Server

    Stifter, Kelly Marie

    2015-01-01

    A new Beam Halo Monitor (BHM) detector system has been installed in the CMS cavern to measure the machine-induced background (MIB) from the LHC. This background originates from interactions of the LHC beam halo with the final set of collimators before the CMS experiment and from beam gas interactions. The BHM detector uses the directional nature of Cherenkov radiation and event timing to select particles coming from the direction of the beam and to supress those originating from the interaction point. It consists of 40 quartz rods, placed on each side of the CMS detector, coupled to UV sensitive PMTs. For each bunch crossing the PMT signal is digitized by a charge integrating ASIC and the arrival time of the signal is recorded. The data are processed in real time to yield a precise measurement of per-bunch-crossing background rate. This measurement is made available to CMS and the LHC, to provide real-time feedback on the beam quality and to improve the efficiency of data taking. In this talk we will descri...

  4. The CMS Beam Halo Monitor Detector System

    CERN Document Server

    Stifter, Kelly

    2015-01-01

    A new Beam Halo Monitor (BHM) detector system has been installed in the CMS cavern to measure the machine-induced background (MIB) from the LHC. This background originates from interactions of the LHC beam halo with the final set of collimators before the CMS experiment and from beam gas interactions. The BHM detector uses the directional nature of Cherenkov radiation and event timing to select particles coming from the direction of the beam and to suppress those originating from the interaction point. It consists of 40 quartz rods, placed on each side of the CMS detector, coupled to UV sensitive PMTs. For each bunch crossing the PMT signal is digitized by a charge integrating ASIC and the arrival time of the signal is recorded. The data are processed in real time to yield a precise measurement of per-bunch-crossing background rate. This measurement is made available to CMS and the LHC, to provide real-time feedback on the beam quality and to improve the efficiency of data taking. Here, I present the detector...

  5. Ion beam polarization in storage rings. Production, controlling and preservation

    Energy Technology Data Exchange (ETDEWEB)

    Prozorov, A. [St. Petersburg State Univ. (Russian Federation). V.A. Fock Research Institute for Physics; Labzowsky, L. [St. Petersburg State Univ. (Russian Federation). V.A. Fock Research Institute for Physics]|[St. Petersburg Nuclear Physics Institute (Russian Federation); Plunien, G. [Technische Univ. Dresden (Germany). Inst. fuer Theoretische Physik; Liesen, D. [Gesellschaft fuer Schwerionenforschung mbH, Darmstadt (Germany)]|[Heidelberg Univ. (Germany). Physikalisches Inst.; Bosch, F. [Gesellschaft fuer Schwerionenforschung mbH, Darmstadt (Germany); Fritzsche, S. [Gesellschaft fuer Schwerionenforschung mbH, Darmstadt (Germany)]|[Heidelberg Univ. (Germany). Physikalisches Inst.]|[Max-Planck Insitute of Nuclear Physics, Heidelberg (Germany); Surzhykov, A. [Max-Planck Insitute of Nuclear Physics, Heidelberg (Germany)

    2008-03-15

    The present paper reports on the actual status of the theoretical concepts for the production of polarized heavy ion beams in storage rings and for methods to control online the degree of polarization as well as investigations of the preservation of the polarization during the ion movement across the magnetic system of the ring. It is argued that for hydrogen-like ions beam polarization can be built up efficiently by optical pumping of the Zeeman sublevels of ground-state hyperfine levels and that the maximal achievable nuclear polarization exceeds 90%. Of special interest are polarized helium-like ions which can be produced by the capture of one electron, because in selected cases parity nonconservation effects are found to be of unprecedented size in Atomic Physics. The measurements of these effects require online-diagnostics of the degree of the ion beam polarization. It is shown that this can be accomplished by an online-detection of the linear polarization of the X-rays which are emitted with the capture of the electron. In order to investigate the preservation of the polarization of the ions stored in the ring, the concept of an instantaneous quantization axis is introduced. The dynamics of this axis and the behaviour of the polarization with respect to it are explored in detail. (orig.)

  6. Quality control and patient dosimetry in dental cone beam CT

    International Nuclear Information System (INIS)

    This paper presents the initial experience in performing quality control and patient dose measurements in a cone beam computed tomography (CT) scanner (ILUMATM Ultra, IMTEC Imaging, USA) for oral and maxillofacial radiology. The X-ray tube and the generator were tested first, including the kVp accuracy and precision, and the half-value layer (HVL). The following tests specific for panoramic dental systems were also performed: tube output, beam size and beam alignment to the detector. The tests specific for CT included measurements of noise and CT numbers in water and in air, as well as the homogeneity of CT numbers. The most appropriate dose quantity was found to be the air kerma-area product (KAP) measured with a KAP-metre installed at the tube exit. KAP values were found to vary from 110 to 185 μGy m2 for available adult protocols and to be 54 μGy m2 for the paediatric protocol. The effective dose calculated with the software PCXMC (STUK (Finland)) was 0.05 mSv for children and 0.09-0.16 mSv for adults. (authors)

  7. J-PARC muon control system

    Energy Technology Data Exchange (ETDEWEB)

    Higemoto, W. [Japan Atomic Energy Agency, Ibaraki 319-1195 (Japan)], E-mail: higemoto.wataru@jaea.go.jp; Shimomura, K.; Kobayashi, Y.; Makimura, S.; Miyake, Y. [High Energy Accelerator Research Organization, Ibaraki 305-0801 (Japan); Kai, T.; Sakai, K. [Japan Atomic Energy Agency, Ibaraki 319-1195 (Japan)

    2009-02-21

    At the J-PARC MLF muon science facility (MUSE), muon experimental instruments are operated by means of a Muon Control System. The following are subject to the Muon Control System: (1) Muon production target and the beam scrapers, (2) M1/M2 line air-conditioning system, (3) Cryogenic system for the superconducting solenoid magnet, (4) Muon secondary line vacuum system, (5) Muon secondary line magnets, and (6) Muon beam blockers and related safety instruments. Details of the muon control system are described below.

  8. Methodological demonstration of laser beam pointing control for space gravitational wave detection missions

    International Nuclear Information System (INIS)

    In space laser interferometer gravitational wave (G.W.) detection missions, the stability of the laser beam pointing direction has to be kept at 10 nrad/√Hz. Otherwise, the beam pointing jitter noise will dominate the noise budget and make the detection of G.W. impossible. Disturbed by the residue non-conservative forces, the fluctuation of the laser beam pointing direction could be a few μrad/√Hz at frequencies from 0.1 mHz to 10 Hz. Therefore, the laser beam pointing control system is an essential requirement for those space G.W. detection missions. An on-ground test of such beam pointing control system is performed, where the Differential Wave-front Sensing technique is used to sense the beams pointing jitter. An active controlled steering mirror is employed to adjust the beam pointing direction to compensate the jitter. The experimental result shows that the pointing control system can be used for very large dynamic range up to 5 μrad. At the interested frequencies of space G.W. detection missions, between 1 mHz and 1 Hz, beam pointing stability of 6 nrad/√Hz is achieved

  9. Reproducible and controllable induction voltage adder for scaled beam experiments.

    Science.gov (United States)

    Sakai, Yasuo; Nakajima, Mitsuo; Horioka, Kazuhiko

    2016-08-01

    A reproducible and controllable induction adder was developed using solid-state switching devices and Finemet cores for scaled beam compression experiments. A gate controlled MOSFET circuit was developed for the controllable voltage driver. The MOSFET circuit drove the induction adder at low magnetization levels of the cores which enabled us to form reproducible modulation voltages with jitter less than 0.3 ns. Preliminary beam compression experiments indicated that the induction adder can improve the reproducibility of modulation voltages and advance the beam physics experiments. PMID:27587112

  10. TECHNICAL NOTE: Fuzzy control of vibration of a smart CFRP laminated beam

    Science.gov (United States)

    Takawa, Takeshi; Fukuda, Takehito; Nakashima, Koichiro

    2000-04-01

    In the present study, the fuzzy control of vibration is investigated for a hybrid smart composite beam actuated by piezoceramics and electro-rheological fluids (ERFs) actuators. A carbon fiber reinforced plastics cantilevered beam containing ERF with bonded piezoceramics is vibrated under forced sinusoidal external excitation. A fuzzy model of the controlled element containing two actuators is formed because the application of a linear control theory to the vibration control is difficult due to intense nonlinearity in the ERF actuator. The parameters of the fuzzy model are identified by using a hybrid neuro-fuzzy system. The fuzzy controller for vibration suppression of the composite beam designed is based on the fuzzy model by using modern control theory. The effect of the vibration control system with a fuzzy controller is verified by simulation and experiment.

  11. Digital Controller For Laser-Beam-Steering Subsystem

    Science.gov (United States)

    Ansari, Homayoon

    1995-01-01

    Report presents additional information about proposed apparatus described in "Beam-Steering Subsystem for Laser Communication" (NPO-19069). Discusses design of digital beam-steering control subsystem and, in particular, that part of design pertaining to digital compensation for frequency response of steering mirror.

  12. Instrumentation control system

    International Nuclear Information System (INIS)

    This book explains instrumentation control system, which mentions summary, basic theory, kinds, control device, and design of each instrumentation system. The contents of this book are introduction of instrumentation system, temperature detector, pressure sensor, flow detector, level detector, ingredient detector, signal convert and transmission, instructions, record and control of instrumentation system, PID controller control valve of instrumentation system, instrumentation equipment of water system, instrumentation facility of thermal power plant, examples of advance instrumentation facility and install and design of instrumentation system.

  13. JT-60 plasma control system

    International Nuclear Information System (INIS)

    JT-60 plasma control can be performed by the supervisory controller, the measurement system and actuators such as the poloidal field coil power supplies, gas injectors, neutral beam injection (NBI) heating system and radio frequency (RF) heating system. One of the most important characteristics of this system is a perfect digital control one composed of mini-computers, fast array processors and CAMAC modules, and it has large flexibility and few troubles to adjust the system. This system started to be operated in April 1985, after the six-year-long design, construction and testing, and have been operated and improved many times for two years. In this paper, the final system specification and its performance are presented aiming at the technological aspect of hardware and software. In addition, and experienced troubles are also presented. (author)

  14. LINAC control automation system

    International Nuclear Information System (INIS)

    A 7 MeV Electron Beam Linear Accelerator (LINAC) being used for pulse radiolysis experiments at RC and CDD, B.A.R.C. has been automated with a PLC based control panel designed and developed by Computer Division, B.A.R.C.. The control panel after power on switches ON various units in a pre-defined sequence and intervals on a single turn of START key from OFF to ON position. The control panel also generates various ramp signals in a pre-defined sequence and rate and steady values and feeds to the LINAC bringing it to the ready for experiment condition. Similarly on a single turn of STOP key from OFF to ON position, the panel ramps down the various signals in pre-defined manners and makes OFF the various units in predefined sequence and timing providing safety to the machine. The steady values for various signals are on line settable as and when required so. This automation system relieves the operator from fatigue of time consuming manual ramping up or down of various signals and running around in four rooms for switching ON or OFF the various units enhancing efficiency and safety. This also facilitates the user scientist to do start up and shutdown operation in the absence of skilled operators and thus adds flexibility for working up to extended timing. This unit has been working satisfactorily since August 2002. For extraordinary condition automation to manual or vice versa change over has been provided. (author)

  15. Controllable circular Airy beams via dynamic linear potential

    CERN Document Server

    Zhong, Hua; Belić, Milivoj R; Li, Changbiao; Wen, Feng; Zhang, Zhaoyang; Zhang, Yanpeng

    2016-01-01

    We investigate controllable spatial modulation of circular autofocusing Airy beams, under action of different dynamic linear potentials, both theoretically and numerically. We introduce a novel treatment method in which the circular Airy beam is represented as a superposition of narrow azimuthally-modulated one-dimensional Airy beams that can be analytically treated. The dynamic linear potentials are appropriately designed, so that the autofocusing effect can either be weakened or even eliminated when the linear potential exerts a "pulling" effect on the beam, or if the linear potential exerts a "pushing" effect, the autofocusing effect can be greatly strengthened. Numerical simulations agree with the theoretical results very well.

  16. NOVANET: communications network for a control system

    International Nuclear Information System (INIS)

    NOVANET is a control system oriented fiber optic local area network that was designed to meet the unique and often conflicting requirements of the Nova laser control system which will begin operation in 1984. The computers and data acquisition devices that form the distributed control system for a large laser fusion research facility need reliable, high speed communications. Both control/status messages and experimental data must be handled. A subset of NOVANET is currently operating on the two beam Novette laser system

  17. National Ignition Facility, subsystem design requirements beam control and laser diagnostics SSDR 1.7

    International Nuclear Information System (INIS)

    This Subsystem Design Requirement document is a development specification that establishes the performance, design, development, and test requirements for the Alignment subsystem (WBS 1.7.1), Beam Diagnostics (WBS 1.7.2), and the Wavefront Control subsystem (WBS 1.7. 3) of the NIF Laser System (WBS 1.3). These three subsystems are collectively referred to as the Beam Control ampersand Laser Diagnostics Subsystem. The NIF is a multi-pass, 192-beam, high-power, neodymium-glass laser that meets requirements set forth in the NIF SDR 002 (Laser System). 3 figs., 3 tabs

  18. A long-range polarization-controlled optical tractor beam

    Science.gov (United States)

    Shvedov, Vladlen; Davoyan, Arthur R.; Hnatovsky, Cyril; Engheta, Nader; Krolikowski, Wieslaw

    2014-11-01

    The laser beam has become an indispensable tool for the controllable manipulation and transport of microscopic objects in biology, physical chemistry and condensed matter physics. In particular, ‘tractor’ laser beams can draw matter towards a laser source and perform, for instance, all-optical remote sampling. Recent advances in lightwave technology have already led to small-scale experimental demonstrations of tractor beams. However, the realization of long-range tractor beams has not gone beyond the realm of theoretical investigations. Here, we demonstrate the stable transfer of gold-coated hollow glass spheres against the power flow of a single inhomogeneously polarized laser beam over tens of centimetres. Additionally, by varying the polarization state of the beam we can stop the spheres or reverse the direction of their motion at will.

  19. Creating High-Harmonic Beams with Controlled Orbital Angular Momentum

    Science.gov (United States)

    Boyd, Robert W.

    A beam of light with an angle-dependent phase Φ = lϕ , where ϕ is the azimuthal coordinate, about the beam axis carries an orbital angular momentum (OAM) of lℏ per photon. Such beams have been exploited to provide superresolution in visible-light microscopy. The ability to create extreme ultraviolet or soft-x-ray beams with controllable OAM would be a critical step towards extending superresolution methods to extremely small feature size. Here we show that OAM is conserved during the process of high-harmonic generation (HHG). Experimentally, we use a fundamental beam with l = 1 and interferometrically determine that the q-th harmonic has an OAM quantum number l equal to its harmonic order q. We also show theoretically how to couple an arbitrary low value of the OAM quantum number l to any harmonic order q in a controlled manner. Our results open a route to microscopy on the molecular, or even submolecular, scale.

  20. Controllable light capsules employing modified Bessel-Gauss beams

    CERN Document Server

    Gong, Lei; Zhao, Qian; Ren, Yuxuan; Qiu, Xingze; Zhong, Mincheng; Li, Yinmei

    2016-01-01

    We report, in theory and experiment, on a novel class of controlled light capsules with nearly perfect darkness, directly employing intrinsic properties of modified Bessel-Gauss beams. These beams are able to naturally create three-dimensional bottle-shaped region during propagation as long as the parameters are properly chosen. Remarkably, the optical bottle can be controlled to demonstrate various geometries through tuning the beam parameters, thereby leading to an adjustable light capsule. We provide a detailed insight into the theoretical origin and characteristics of the light capsule derived from modified Bessel-Gauss beams. Moreover, a binary digital micromirror device (DMD) based scheme is first employed to shape the bottle beams by precise amplitude and phase manipulation. Further, we demonstrate their ability for optical trapping of core-shell magnetic microparticles, which play a particular role in biomedical research, with holographic optical tweezers. Therefore, our observations provide a new rou...

  1. Tuning of Graphene Properties via Controlled Exposure to Electron Beams

    OpenAIRE

    Liu, G; Teweldebrhan, D.; Balandin, A. A.

    2010-01-01

    Controlled modification of graphene properties is essential for its proposed electronic applications. Here we describe a possibility of tuning electrical properties of graphene via electron beam irradiation. We show that by controlling the irradiation dose one can change the carrier mobility and increase the resistance at the minimum conduction point in the single layer graphene. The bilayer graphene is less susceptible to the electron beam irradiation. The modification of graphene properties...

  2. Ball on a beam: stabilization under saturated input control with large basin of attraction

    CERN Document Server

    Aoustin, Yannick; 10.1007/s11044-008-9128-0

    2010-01-01

    This article is devoted to the stabilization of two underactuated planar systems, the well-known straight beam-and-ball system and an original circular beam-and-ball system. The feedback control for each system is designed, using the Jordan form of its model, linearized near the unstable equilibrium. The limits on the voltage, fed to the motor, are taken into account explicitly. The straight beam-and-ball system has one unstable mode in the motion near the equilibrium point. The proposed control law ensures that the basin of attraction coincides with the controllability domain. The circular beam-and-ball system has two unstable modes near the equilibrium point. Therefore, this device, never considered in the past, is much more difficult to control than the straight beam-and-ball system. The main contribution is to propose a simple new control law, which ensures by adjusting its gain parameters that the basin of attraction arbitrarily can approach the controllability domain for the linear case. For both nonlin...

  3. Ramsey-type phase control of free electron beams

    CERN Document Server

    Echternkamp, Katharina E; Schäfer, Sascha; Ropers, Claus

    2016-01-01

    Interference between multiple distinct paths is a defining property of quantum physics, where "paths" may involve actual physical trajectories, as in interferometry, or transitions between different internal (e.g. spin) states, or both. A hallmark of quantum coherent evolution is the possibility to interact with a system multiple times in a phase-preserving manner. This principle underpins powerful multi-dimensional optical and nuclear magnetic resonance spectroscopies and related techniques, including Ramsey's method of separated oscillatory fields used in atomic clocks. Previously established for atomic, molecular and quantum dot systems, recent developments in the optical quantum state preparation of free electron beams suggest a transfer of such concepts to the realm of ultrafast electron imaging and spectroscopy. Here, we demonstrate the sequential coherent interaction of free electron states with two spatially separated, phase-controlled optical near-fields. Ultrashort electron pulses are acted upon in ...

  4. Indexing system for optical beam steering

    Science.gov (United States)

    Sullivan, Mark T.; Cannon, David M.; Debra, Daniel B.; Young, Jeffrey A.; Mansfield, Joseph A.; Carmichael, Roger E.; Lissol, Peter S.; Pryor, G. M.; Miklosy, Les G.; Lee, Jeffrey H.

    1990-01-01

    This paper describes the design and testing of an indexing system for optical-beam steering. The cryogenic beam-steering mechanism is a 360-degree rotation device capable of discrete, high-precision alignment positions. It uses low-precision components for its rough alignment and kinematic design to meet its stringent repeatability and stability requirements (of about 5 arcsec). The principal advantages of this design include a decoupling of the low-precision, large angular motion from the high-precision alignment, and a power-off alignment position that potentially extends the life or hold time of cryogenic systems. An alternate design, which takes advantage of these attributes while reducing overall motion, is also presented. Preliminary test results show the kinematic mount capable of sub-arc second repeatability.

  5. Beam dynamics in the SLC final focus system

    International Nuclear Information System (INIS)

    The SLC luminosity is reached by colliding beams focused to about 2 μm transverse sizes. The Final Focus System (FFS) must enable, beyond its basic optical design, the detection and correction of errors accumulated in the system. In this paper, after summarizing the design, we review the sensitivity to such errors and the ability to correct them. The overall tuning strategy involves three phases: single beam spot minimization, steering the beams in collision and luminosity optimization with beam-beam effects

  6. Beam diagnostics and data acquisition system for ion beam transport line used in applied research

    International Nuclear Information System (INIS)

    Ion beam transport line for applied research on U-400 cyclotron, beam diagnostics and data acquisition system for condensed matter studies are described. The main features of Windows-based real time program are considered

  7. Control system design method

    Science.gov (United States)

    Wilson, David G.; Robinett, III, Rush D.

    2012-02-21

    A control system design method and concomitant control system comprising representing a physical apparatus to be controlled as a Hamiltonian system, determining elements of the Hamiltonian system representation which are power generators, power dissipators, and power storage devices, analyzing stability and performance of the Hamiltonian system based on the results of the determining step and determining necessary and sufficient conditions for stability of the Hamiltonian system, creating a stable control system based on the results of the analyzing step, and employing the resulting control system to control the physical apparatus.

  8. Colliding beam fusion reactor space propulsion system

    Science.gov (United States)

    Wessel, Frank J.; Binderbauer, Michl W.; Rostoker, Norman; Rahman, Hafiz Ur; O'Toole, Joseph

    2000-01-01

    We describe a space propulsion system based on the Colliding Beam Fusion Reactor (CBFR). The CBFR is a high-beta, field-reversed, magnetic configuration with ion energies in the range of hundreds of keV. Repetitively-pulsed ion beams sustain the plasma distribution and provide current drive. The confinement physics is based on the Vlasov-Maxwell equation, including a Fokker Planck collision operator and all sources and sinks for energy and particle flow. The mean azimuthal velocities and temperatures of the fuel ion species are equal and the plasma current is unneutralized by the electrons. The resulting distribution functions are thermal in a moving frame of reference. The ion gyro-orbit radius is comparable to the dimensions of the confinement system, hence classical transport of the particles and energy is expected and the device is scaleable. We have analyzed the design over a range of 106-109 Watts of output power (0.15-150 Newtons thrust) with a specific impulse of, Isp~106 sec. A 50 MW propulsion system might involve the following parameters: 4-meters diameter×10-meters length, magnetic field ~7 Tesla, ion beam current ~10 A, and fuels of either D-He3,P-B11,P-Li6,D-Li6, etc. .

  9. The ATLAS Detector Control System

    CERN Document Server

    Schlenker, S; Kersten, S; Hirschbuehl, D; Braun, H; Poblaguev, A; Oliveira Damazio, D; Talyshev, A; Zimmermann, S; Franz, S; Gutzwiller, O; Hartert, J; Mindur, B; Tsarouchas, CA; Caforio, D; Sbarra, C; Olszowska, J; Hajduk, Z; Banas, E; Wynne, B; Robichaud-Veronneau, A; Nemecek, S; Thompson, PD; Mandic, I; Deliyergiyev, M; Polini, A; Kovalenko, S; Khomutnikov, V; Filimonov, V; Bindi, M; Stanecka, E; Martin, T; Lantzsch, K; Hoffmann, D; Huber, J; Mountricha, E; Santos, HF; Ribeiro, G; Barillari, T; Habring, J; Arabidze, G; Boterenbrood, H; Hart, R; Marques Vinagre, F; Lafarguette, P; Tartarelli, GF; Nagai, K; D'Auria, S; Chekulaev, S; Phillips, P; Ertel, E; Brenner, R; Leontsinis, S; Mitrevski, J; Grassi, V; Karakostas, K; Iakovidis, G.; Marchese, F; Aielli, G

    2011-01-01

    The ATLAS experiment is one of the multi-purpose experiments at the Large Hadron Collider (LHC), constructed to study elementary particle interactions in collisions of high-energy proton beams. Twelve different sub-detectors as well as the common experimental infrastructure are supervised by the Detector Control System (DCS). The DCS enables equipment supervision of all ATLAS sub-detectors by using a system of >130 server machines running the industrial SCADA product PVSS. This highly distributed system reads, processes and archives of the order of 106 operational parameters. Higher level control system layers allow for automatic control procedures, efficient error recognition and handling, and manage the communication with external systems such as the LHC. This contribution firstly describes the status of the ATLAS DCS and the experience gained during the LHC commissioning and the first physics data taking operation period. Secondly, the future evolution and maintenance constraints for the coming years an...

  10. Active steering system for the neutral beam injector for ITER

    International Nuclear Information System (INIS)

    ITER requires an additional power injection of 33 MW from neutral beams, which can be provided by two injectors, delivering 16.5 MW each, having an ion current of 40 A and an accelerating voltage of 1 MV. The requirement of on-axis and off-axis injection into ITER is presently accomplished by mechanical tilting of the injector source. To preserve the integrity of the beam line components, on the horizontal plane, very tight misalignment is tolerable (±3 mrad); such accuracy requires precise installation of the components. Breaking the vacuum and executing a long series of operations is required to provide proper beam alignment. It would be helpful if such alignments could be performed remotely. A study has been conducted on the possibility of steering the negative ions by suitable magnetic fields, generated by dedicated coils located at the exit of the accelerator. It results that the magnetic system can meet the requirements in terms of beam alignment. The steering system will heavily affect the trajectory of the electrons extracted from the accelerator and can be used to deflect the electrons onto suitable dump plates. The system can steer the ions and dump the electrons in a controlled way, even in case of modulation of the acceleration voltage; a flexible beam aiming system can be used to adapt the power deposition profile in ITER to the plasma characteristics; active steering can provide a suitable way to control the power deposition with respect to the possibility of exciting Alfven eigenmodes, which can reduce the performances of ITER plasmas. The present contribution reviews the preliminary design of the active steering system and provides an analysis of advantages and disadvantages. (author)

  11. Microcontroller based two axis microtron beam extraction system

    International Nuclear Information System (INIS)

    Microtron is an electron accelerator which is used to accelerate the electron beam. The Microtron consists of electro magnet with two poles separated by yoke for completion of path for magnetic flux lines. A compact Microtron capable of accelerating electrons up to 12 MeV has been developed in RRCAT. The beam from the Microtron has to be extracted from various orbits depending upon the user requirement (X-Y stage is built with an accuracy of 100 μm). This paper describes the design and development of microcontroller based two axis beam extraction system for Microtron, with a resolution of 50 μm to position the extraction tube with respect to selected orbit. Two axis motion controller is developed using current controlled micro-stepping driver mechanism, which uses Bipolar Chopper Drive for driving stepper motors. Each phase has 2A continuous driving capability. The system is provided with user selectable controls like speed, steps, direction, and mode. This system is provided with RS-232 interface, to accept commands from PC. This system also has local keyboard and LCD interface to use in Stand-alone mode (local Mode). (author)

  12. GCFR plant control system

    International Nuclear Information System (INIS)

    A plant control system is being designed for a gas-cooled fast breeder reactor (GCFR) demonstration plant. Control analysis is being performed as an integral part of the plant design process to ensure that control requirements are satisfied as the plant design evolves. The load control portion of the plant control system provides stable automatic (closed-loop) control of the plant over the 25% to 100% load range. Simulation results are presented to demonstrate load control system performance. The results show that the plant is controllable at full load with the control system structure selected, but gain scheduling is required to achieve desired performance over the load range

  13. Electrowetting-Controlled Dual Liquid Prism for Adaptive Beam Steering

    Science.gov (United States)

    Cheng, Jiangtao

    2015-03-01

    The use of concentrating photovoltaic (CPV) technology has been the most promising method of harvesting solar radiation. These CPV systems often require motor-driven tracking devices to steer the sun's beams onto solar cells. The cost of maintaining these tracking systems is the primary inhibitor for widespread application. We aim to overcome the need for mechanical trackers through the use of an electrowetting-driven solar tracking (EWST) system. The electrowetting-driven solar tracking system consists of an array of novel electrowetting-controlled dual liquid prisms, which are filled with immiscible fluids that have large differences in refractive indices. The naturally formed meniscus between the fluids can function as a dynamic optical prism. Via the full-range modulation of the liquid prisms, incident sunlight can be adaptively tracked, steered, and focused onto CPV cells through a fixed optical condenser. Furthermore, unlike the conventional and cumbersome motor-driven tracking systems used today, the liquid prism system would be suitable for rooftop applications. The results of this project reveal that the EWST system has the potential to generate ~ 70% more green energy at 50% of the conventional capital cost.

  14. Active buckling control of beams using piezoelectric actuators and strain gauge sensors

    International Nuclear Information System (INIS)

    In this paper, a finite element model incorporating active control techniques has been developed to stabilize the first two buckling modes of both a simply supported and a cantilevered beam. The goal is to increase the corresponding beam buckling loads by using piezoelectric actuators along with optimal feedback control. The uniform beams are bonded with two pairs of segmented piezoelectric actuators at the top and bottom. Resistive strain gauges are attached to the centres of the actuators as sensors. Measurements are taken using these, to estimate the system states. The beams are simply supported or cantilevered and subjected to a slowly increasing axial compressive load. Finite element formulations based on the classical Euler–Bernoulli beam theory and linear piezoelectric constitutive equations for the actuators are presented. The associated reduced-order modal equations and the state-space equations are derived for the design of a standard linear quadratic regulator (LQR). The finite element analysis and the active control simulation results are consistent with both theoretical analysis results and experimental data. The designed full state feedback LQR controller is shown to be successful in stabilizing the first two buckling modes of the beams. Also the control simulation shows that the present optimally located segmented actuator pairs along the beam are more effective for buckling control

  15. Design of CMS Beam Halo Monitor system

    CERN Document Server

    AUTHOR|(CDS)2078842

    2015-01-01

    A fast and directional monitoring system for the CMS experiment is designed to provide an online, bunch-by-bunch measurement of beam background induced by beam halo interactions, separately for each beam. The background detection is based on Cherenkov radiation produced in synthetic fused silica read out by a fast, UV sensitive photomultiplier tube. Twenty detector units per end will be azimuthally distributed around the rotating shielding of CMS, covering ~408 cm2 at 20.6m from the interaction point, at a radius of ~180 cm. The directional and fast response of the system allows the discrimination of the background particles from the dominant flux in the cavern induced by pp collision debris, produced within the 25 ns bunch spacing. A robust multi-layered shielding will enclose each detector unit to protect the photomultiplier tube from the magnetic field and to eliminate the occupancy from low energy particles. The design of the front-end units is validated by experimental results. An overview of the new sy...

  16. Internal Control System

    OpenAIRE

    Pavésková, Ivana

    2009-01-01

    This thesis is focused on internal control system. The aim of this thesis is to analyse the development and elements of internal control system, and then demonstrate the possible form of the internal control system in practice. The thesis is divided into two parts -- theoretical and practical. The beginning of the theoretical part is devoted to characteristics of internal controls and their relation to internal control, attention is also paid to economic crimes which the internal control syst...

  17. Electron beam irradiation in polymeric systems

    International Nuclear Information System (INIS)

    The electron beam applications in the chemistry of polymers, such as the production of acrylamide polymers, which are of great interest in the treatment of waste industrial waters are given. These products have unique properties: the required dose is smaller by a factor of 10 to 50 as compared to the dose requirement for other polymeric materials and they are used in aqueous solutions in a concentration of one or two magnitude orders smaller than the conventional inorganic flocculants. The acrylamide polymers technologies was first developed at semi-industrial scale with IETI 10000 gamma rays source and then transferred to the ALIN-10 electron linear accelerator. The operation of the ALIN-10 built in the Accelerator Laboratory from the Institute of Atomic Physics is presented. An original feature of this accelerator, using an electron gun of the diode type is its capability to obtain programmed beam single shots and pulse trains. It is particularly useful for the automatic control of irradiation processing in order to provide the maximum efficiency of the electron beam application. The preliminary results obtained by ALIN-10 lead to the assumption that the low output power high energy linacs are economically attractive for the commercial production of acrylamide type polymers. (Author) 7 Figs. 2 Tabs., 10 Refs

  18. An interactive beam position monitor system simulator

    International Nuclear Information System (INIS)

    A system simulator has been implemented to aid the development of the RHIC position monitor system. Based on the LabVIEW software package by National Instruments, this simulator allows engineers and technicians to interactively explore the parameter space of a system during the design phase. Adjustable parameters are divided into three categories: beam, pickup, and electronics. The simulator uses these parameters in simple formulas to produce results in both time-domain and frequencydomain. During the prototyping phase, these simulated results can be compared to test data acquired with the same software package. The RHIC position monitor system is presented as an example, but the software is applicable to several other systems as well

  19. Beam position monitor system of J-PARC RCS

    International Nuclear Information System (INIS)

    The J-PARC RCS is a 25 Hz Rapid-Cycling proton Synchrotron and its designed beam power is 1 MW. The beam position monitor (BPM) system at J-PARC RCS is described in this paper. The pre-defined diameter of the BPM detectors is larger than 250 mm, however, the system has to measure the beam position very accurately. In addition, it is necessary to have a large dynamic range. The system should work not only for the high intensity but also for low intensity, such as during beam commissioning, when the intensity is below 1% of the design intensity. There are 54 BPM detectors around the ring and most of them are placed inside steering magnets because of quite limited space. The BPM detector is an electro-static type and it has four electrodes, and a pair of electrodes gives a good linear response with a diagonal cut shape to detect the charge center precisely. The signal processing units, which are equipped with 14-bit 40 MS/s ADC and 600 MHz DSP, have been developed. They are accessed via shared memory space and controlled by EPICS. Such a processing unit is capable of recording the full 25 Hz pulse data for the so-called “COD mode” (averaged beam position calculation) and it can also store the whole waveform data for further analysis, like turn-by-turn position calculation. The resolution was estimated to be 20μm for “COD mode” and to be 0.3 mm for the turn-by-turn mode with relatively low intensity of 8×1011ppp. The position accuracy is estimated to be about 0.5 mm using a newly developed Beam Based Alignment (BBA) method.

  20. Sagnac Interferometer Based Generation of Controllable Cylindrical Vector Beams

    Directory of Open Access Journals (Sweden)

    Cristian Acevedo

    2016-01-01

    Full Text Available We report on a novel experimental geometry to generate cylindrical vector beams in a very robust manner. Continuous control of beams’ properties is obtained using an optically addressable spatial light modulator incorporated into a Sagnac interferometer. Forked computer-generated holograms allow introducing different topological charges while orthogonally polarized beams within the interferometer permit encoding the spatial distribution of polarization. We also demonstrate the generation of complex waveforms obtained by combining two orthogonal beams having both radial modulations and azimuthal dislocations.

  1. Beam Intensity and Energy Control for the SPIRAL2 Facility

    OpenAIRE

    Jamet, C.; André, T.; Ducoudret, B.; Doutressoulles, C.; Le Coz, W.; Ledu, G.; Leloir, S.; Loret, S.

    2012-01-01

    TUPB029 - ISBN 878-3-95450-122-9 International audience The first part of the SPIRAL2 facility, which entered last year in the construction phase at GANIL in France, consists of an ion source, a deuteron and a proton source, a RFQ and a superconducting linear accelerator delivering high intensities, up to 5 mA and 40 MeV for the deuteron beams. Diagnostic developments have been done to control both beam intensity and energy by non-interceptive methods at the linac exit. The beam current...

  2. Multiplexed broadband beam steering system utilizing high speed MEMS mirrors

    OpenAIRE

    Knoernschild, Caleb; Kim, Changsoon; Lu, Felix P.; Kim, Jungsang

    2009-01-01

    We present a beam steering system based on micro-electromechanical systems technology that features high speed steering of multiple laser beams over a broad wavelength range. By utilizing high speed micromirrors with a broadband metallic coating, our system has the flexibility to simultaneously incorporate a wide range of wavelengths and multiple beams. We demonstrate reconfiguration of two independent beams at different wavelengths (780 and 635 nm) across a common 5x5 array with 4 us settlin...

  3. GENERATION AND CONTROL OF HIGH PRECISION BEAMS AT LEPTON ACCELERATORS

    Energy Technology Data Exchange (ETDEWEB)

    Yu-Chiu Chao

    2007-06-25

    Parity violation experiments require precision manipulation of helicity-correlated beam coordinates on target at the nm/nrad-level. Achieving this unprecedented level of control requires a detailed understanding of the particle optics and careful tuning of the beam transport to keep anomalies from compromising the design adiabatic damping. Such efforts are often hindered by machine configuration and instrumentation limitations at the low energy end. A technique has been developed at CEBAF including high precision measurements, Mathematica-based analysis for obtaining corrective solutions, and control hardware/software developments for realizing such level of control at energies up to 5 GeV.

  4. Controllable light capsules employing modified Bessel-Gauss beams.

    Science.gov (United States)

    Gong, Lei; Liu, Weiwei; Zhao, Qian; Ren, Yuxuan; Qiu, Xingze; Zhong, Mincheng; Li, Yinmei

    2016-01-01

    We report, in theory and experiment, on a novel class of controlled light capsules with nearly perfect darkness, directly employing intrinsic properties of modified Bessel-Gauss beams. These beams are able to naturally create three-dimensional bottle-shaped region during propagation as long as the parameters are properly chosen. Remarkably, the optical bottle can be controlled to demonstrate various geometries through tuning the beam parameters, thereby leading to an adjustable light capsule. We provide a detailed insight into the theoretical origin and characteristics of the light capsule derived from modified Bessel-Gauss beams. Moreover, a binary digital micromirror device (DMD) based scheme is first employed to shape the bottle beams by precise amplitude and phase manipulation. Further, we demonstrate their ability for optical trapping of core-shell magnetic microparticles, which play a particular role in biomedical research, with holographic optical tweezers. Therefore, our observations provide a new route for generating and controlling bottle beams and will widen the potentials for micromanipulation of absorbing particles, aerosols or even individual atoms. PMID:27388558

  5. Adaptive shared control system

    OpenAIRE

    Sanders, David

    2009-01-01

    A control system to aid mobility is presented that is intended to assist living independently and that provides physical guidance. The system has two levels: a human machine interface and an adaptive shared controller.

  6. LHCb: Beam and Background Monitoring and the Upgrade of the Timing and Fast Control System of the LHCb experiment at CERN

    CERN Multimedia

    Alessio, F

    2009-01-01

    The LHCb experiment at CERN is preparing for first real data taking, foreseen by the end of the year 2009 with the start-up of the LHC. A large amount of work of commissioning, tests and improvements of the full detector has been done in order to optimize its performance. During my first year as a Doctoral Student at CERN, I have been working on the timing and readout control of the LHCb experiment in the frame of the LHCb Online group. The group is responsible for the full data acquisition of the LHCb experiment, from the Front-End Electronics (FEE) to the storage of the data for offline analysis, as well as the Timing and Fast Control (TFC) system. The latter controls and distributes centrally timing and trigger information, as well as synchronous and asynchronous commands to the readout system. It is also responsible for receiving and adjusting the bunch and orbit clocks of the LHC machine and distributing it to the electronics of the whole experiment. It is of vital importance to assure that the timing o...

  7. Electronic system for optical shutter control

    Science.gov (United States)

    Viljoen, H. C.; Gaylord, T. K.

    1976-01-01

    The paper describes a precise and versatile electronic system for shutter control in light beam experiments. Digital and analog circuitry is used to provide automatic timing, exposure control, manual operation, and remote programmability. A block diagram of the system is presented and the individual circuits - the timer control circuit, the clock control circuit, the comparator circuit, the exposure (integrator) circuit, and the shutter drive circuit are discussed in detail and diagrams are provided.

  8. On Controlled P Systems

    OpenAIRE

    Krithivasan, Kamala; Paun, Gheorghe; Ramanujan, Ajeesh; Research Group on Natural Computing (Universidad de Sevilla) (Coordinador)

    2013-01-01

    We introduce and brie y investigate P systems with controlled computations. First, P systems with label restricted transitions are considered (in each step, all rules used have either the same label, or, possibly, the empty label, ), then P systems with the computations controlled by languages (as in context-free controlled grammars). The relationships between the families of sets of numbers computed by the various classes of controlled P systems are investigated, also comp...

  9. Dosimetric precision of an ion beam tracking system

    International Nuclear Information System (INIS)

    Scanned ion beam therapy of intra-fractionally moving tumors requires motion mitigation. GSI proposed beam tracking and performed several experimental studies to analyse the dosimetric precision of the system for scanned carbon beams. A beam tracking system has been developed and integrated in the scanned carbon ion beam therapy unit at GSI. The system adapts pencil beam positions and beam energy according to target motion. Motion compensation performance of the beam tracking system was assessed by measurements with radiographic films, a range telescope, a 3D array of 24 ionization chambers, and cell samples for biological dosimetry. Measurements were performed for stationary detectors and moving detectors using the beam tracking system. All detector systems showed comparable data for a moving setup when using beam tracking and the corresponding stationary setup. Within the target volume the mean relative differences of ionization chamber measurements were 0.3% (1.5% standard deviation, 3.7% maximum). Film responses demonstrated preserved lateral dose gradients. Measurements with the range telescope showed agreement of Bragg peak depth under motion induced range variations. Cell survival experiments showed a mean relative difference of -5% (-3%) between measurements and calculations within the target volume for beam tracking (stationary) measurements. The beam tracking system has been successfully integrated. Full functionality has been validated dosimetrically in experiments with several detector types including biological cell systems

  10. Dosimetric precision of an ion beam tracking system

    Directory of Open Access Journals (Sweden)

    Kraft Gerhard

    2010-06-01

    Full Text Available Abstract Background Scanned ion beam therapy of intra-fractionally moving tumors requires motion mitigation. GSI proposed beam tracking and performed several experimental studies to analyse the dosimetric precision of the system for scanned carbon beams. Methods A beam tracking system has been developed and integrated in the scanned carbon ion beam therapy unit at GSI. The system adapts pencil beam positions and beam energy according to target motion. Motion compensation performance of the beam tracking system was assessed by measurements with radiographic films, a range telescope, a 3D array of 24 ionization chambers, and cell samples for biological dosimetry. Measurements were performed for stationary detectors and moving detectors using the beam tracking system. Results All detector systems showed comparable data for a moving setup when using beam tracking and the corresponding stationary setup. Within the target volume the mean relative differences of ionization chamber measurements were 0.3% (1.5% standard deviation, 3.7% maximum. Film responses demonstrated preserved lateral dose gradients. Measurements with the range telescope showed agreement of Bragg peak depth under motion induced range variations. Cell survival experiments showed a mean relative difference of -5% (-3% between measurements and calculations within the target volume for beam tracking (stationary measurements. Conclusions The beam tracking system has been successfully integrated. Full functionality has been validated dosimetrically in experiments with several detector types including biological cell systems.

  11. Active vibration suppression in a flexible cantilever beam using fuzzy logic controllers

    International Nuclear Information System (INIS)

    This paper presents a novel control system to find suitable solution for addressing the vibration problems in fixed-free cantilever beam system structures. The solution n is generated using fuzzy logic controller (FLC) utilizing single and multiple control actuators. The fuzzy controller employs the error (between a reference model output and the cantilever response) and error change to generate the control input increment in order to preserve the desired reference model performance. The controller is tested within a simulation environment. Results show that an excellent control performance is possible. (author). 14 refs. 3 tab., 15 figs

  12. Non-Linear Beam Transport System for the LENS 7 MeV Proton Beam

    CERN Document Server

    Jones, William P; Derenchuk, Vladimir Peter; Rinckel, Thomas; Solberg, Keith

    2005-01-01

    A beam transport system has been designed to carry a high-intensity low-emittance proton beam from the exit of the RFQ-DTL acceleration system of the Indiana University Low Energy Neutron System (LENS)* to the neutron production target. The goal of the design was to provide a beam of uniform density over a 3cm by 3cm area at the target. Two octupole magnets** are employed in the beam line to provide the necessary beam phase space manipulations to achieve this goal. First order calculations were done using TRANSPORT and second order calculations have been performed using TURTLE. Second order simulations have been done using both a Gaussian beam distribution and a particle set generated by calculations of beam transport through the RFQ-DTL using PARMILA. Comparison of the design characteristics with initial measurements from the LENS commissioning process will be made.

  13. LHC Beam Loss Monitoring System Verification Applications

    CERN Document Server

    Dehning, B; Zamantzas, C; Jackson, S

    2011-01-01

    The LHC Beam Loss Mon­i­tor­ing (BLM) sys­tem is one of the most com­plex in­stru­men­ta­tion sys­tems de­ployed in the LHC. In ad­di­tion to protecting the col­lid­er, the sys­tem also needs to pro­vide a means of di­ag­nos­ing ma­chine faults and de­liv­er a feed­back of loss­es to the control room as well as to sev­er­al sys­tems for their setup and analysis. It has to trans­mit and pro­cess sig­nals from al­most 4’000 mon­i­tors, and has near­ly 3 mil­lion con­fig­urable pa­ram­e­ters. The system was de­signed with re­li­a­bil­i­ty and avail­abil­i­ty in mind. The spec­i­fied op­er­a­tion and the fail-safe­ty stan­dards must be guar­an­teed for the sys­tem to per­form its func­tion in pre­vent­ing su­per­con­duc­tive mag­net de­struc­tion caused by par­ti­cle flux. Main­tain­ing the ex­pect­ed re­li­a­bil­i­ty re­quires ex­ten­sive test­ing and ver­i­fi­ca­tion. In this paper we re­port our most re­cent ad­di­t...

  14. A disturbance observer-based adaptive control approach for flexure beam nano manipulators.

    Science.gov (United States)

    Zhang, Yangming; Yan, Peng; Zhang, Zhen

    2016-01-01

    This paper presents a systematic modeling and control methodology for a two-dimensional flexure beam-based servo stage supporting micro/nano manipulations. Compared with conventional mechatronic systems, such systems have major control challenges including cross-axis coupling, dynamical uncertainties, as well as input saturations, which may have adverse effects on system performance unless effectively eliminated. A novel disturbance observer-based adaptive backstepping-like control approach is developed for high precision servo manipulation purposes, which effectively accommodates model uncertainties and coupling dynamics. An auxiliary system is also introduced, on top of the proposed control scheme, to compensate the input saturations. The proposed control architecture is deployed on a customized-designed nano manipulating system featured with a flexure beam structure and voice coil actuators (VCA). Real time experiments on various manipulating tasks, such as trajectory/contour tracking, demonstrate precision errors of less than 1%. PMID:26546099

  15. Photorefractive beam-steering system that uses energy transfer in a BaTiO3 crystal for a fiber-array interconnect

    OpenAIRE

    Mathey, Pierre; Mercier, Raymond; Pauliat, Gilles; Roosen, Gérald; Gravey, Philippe

    1995-01-01

    Abeam-control system to write gratings on a holographic plane is studied. The arrangement is designed to interconnect two 1024 monomode fiber arrays. The beam-control system is composed of two subsystems: a beam steerer, which deflects one incident beam toward 1024 positions, and a collimating system, which adapts the shape of the deflected beam to the holographic plane. The collimating system was studied only after the beam steerer had been fully built and tested. It is based on the photoref...

  16. Implementation to spanish protocol of quality control of accelerators to daily control of electron beams

    International Nuclear Information System (INIS)

    A revised procedure for daily control of the electron beams to make measurements more meaningful physically, having a better reproducibility and more in line with the recommendations of the Spanish Protocol for Quality Control in Electron Linear Accelerators Clinical Use. The daily quality control beams of high energy electrons that had been done so far was the finding that the record of a series of measures (symmetry, uniformity, stability, energy, beam central dose) were within tolerance values established. The amendment is to check the beam quality by directly measuring changes in absorption depth at which the dose is reduced to half its maximum value, R50.

  17. Feasibility test to control algal bloom using electron beam irradiation

    International Nuclear Information System (INIS)

    Efforts were made to assess the feasibility to control algal growth using electron beam irradiation. Fresh water algae (e.g. Chlorella sp., Scenedesmus sp., Microcystis sp., Anabaena sp., Oscillatoria sp.) and sea water red algae (e.g. Procentrium minimum, Lingulodinium polyedra, Cochlodinium polykrikoides, Scrippsiella trochoidea, Procentrium micans) were cultured in laboratory and irradiated at different dose of 1.0-10kGy by ELV-4 model electron beam accelerator. The results indicated that in spite of low dose, electron beam irradiation have a great effect on the algal photosynthetic activity; especially for sea water red algae, approximately 40% reduction in chlorophyll-a concentration was observed right after electron beam irradiation at 1.0kGy. Decrease in photosynthetic activity of sea water red algae was more pronounced than that of fresh water algae. With regard to fresh water algae, blue green algae(e.g. Microcystis sp., Oscillatoria sp.) was more vulnerable to electron beam exposure than green algae(e.g. Chlorella sp., Scenedesmus sp.). It is interesting to observe that complete bioflocculation marked by cell aggregation and rapid settling of fresh water algae occurred within 2 days after electron beam irradiation. Continuous mixing was one of the important factors to induce algal bioflocculation. Algal removal and settleable matter production were found to be proportional to irradiation dose and mixing intensity. It is likely that electron beam irradiation damages cell contents including chlorophyll-a, releasing extracellular biopolymer that can be used for inducing bioflocculation. (author)

  18. Monolithic millimeter-wave diode array beam controllers: Theory and experiment

    Science.gov (United States)

    Sjogren, L. B.; Liu, H.-X. L.; Wang, F.; Liu, T.; Wu, W.; Qin, X.-H.; Chung, E.; Domier, C. W.; Luhmann, N. C., Jr.; Maserjian, J.

    1992-01-01

    In the current work, multi-function beam control arrays have been fabricated and have successfully demonstrated amplitude control of transmitted beams in the W and D bands (75-170 GHz). While these arrays are designed to provide beam control under DC bias operation, new designs for high-speed electronic and optical control are under development. These arrays will fill a need for high-speed watt-level beam switches in pulsed reflectometer systems under development for magnetic fusion plasma diagnostics. A second experimental accomplishment of the current work is the demonstration in the 100-170 GHz (D band) frequency range of a new technique for the measurement of the transmission phase as well as amplitude. Transmission data can serve as a means to extract ('de-embed') the grid parameters; phase information provides more complete data to assist in this process. Additional functions of the array beam controller yet to be tested include electronically controlled steering and focusing of a reflected beam. These have application in the areas of millimeter-wave electronic scanning radar and reflectometry, respectively.

  19. Conceptual Design of Neutral Beam Injection System for EAST

    Science.gov (United States)

    Hu, Chundong; NBI Team

    2012-06-01

    Neutral beam injection (NBI) system with two neutral beam injections will be constructed on the Experimental Advanced Superconducting Tokamak (EAST) in two stages for high power auxiliary plasmas heating and non-inductive current drive. Each NBI can deliver 2~4 MW beam power with 50~80 keV beam energy in 10~100 s pulse length. Each elements of the NBI system are presented in this contribution.

  20. The fast beam interlock system for JET neutral injection

    International Nuclear Information System (INIS)

    The JET Neutral Beam Injection (NBI) system poses severe interlock problems with the possibility of unsafe conditions arising on a fast timescale. In order to cope with this the high-security Fast Beam Interlock System (FBIS) has been developed. It is used to turn off the beams in a failsafe manner when a condition arises which could damage the beam line or torus on a timescale too short to be dealt with by the JET Central Interlock and Safety System (CISS). FBIS interfaces signals from many JET safety systems and processes them to act directly on the Neutral Beam power supplies. The interfaces and the fail safety operation of FBIS are described. It is presently planned to upgrade the system to include a real-time comparison of the ion beam deflection magnet currents and the beam extraction voltage and a system which will compensate for the effects of the Tokamak stray fields on the NBI beamlines

  1. Current status of electron beam processing system and its applications

    International Nuclear Information System (INIS)

    The feature and application fields of electron beam processing systems (EPS), the selection of machine ratings and safety measures for EPS are described. EPS has the various features: a) Chemical reactions occurs independent of the temperature, b) it occurs without any added substances such as catalysts, c) mass productivity, d) easy operation, as is exemplified by switch ON and OFF, and e) easy maintenance, compared with radioisotope sources. After briefly explaining acceleration type (DC or AC), power supply (Van-de-Graaf or Cockcroft-walton and others), beam scanning to be used for large area irradiation, and some typical applications (cross-linking, radical polymerization, the paper describes necessary safety measures such as X-ray shielding, ozone control including ozone generation and its disposal, interlock system, warning buzzer, and monitoring and measuring. (S. Ohno)

  2. Experimental study of delayed positive feedback control for a flexible beam

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    Recently, some researches indicate that positive feedback can benefit the control if appropriate time delay is intentionally introduced into control system. However, most work is theoretical one but few are experimental. This paper presents theoretical and experimental studies of delayed positive feedback control technique using a flexible beam as research object. The positive feedback weighting coefficient is designed by using the optimal control method. The available time delay is determined by analyzing ...

  3. Instrumentation for diagnostics and control of laser-accelerated proton (ion) beams

    OpenAIRE

    Bolton, P. R.; Borghesi, M. (Massimo); Brenner, C.; Carroll, D C; Martinis, C.; Fiorini, F.; Flacco, A.; Floquet, V; J. Fuchs; Gallegos, P.; Giove, D.; Green, J S; Green, S; Jones, B.; Kirby, D.

    2014-01-01

    Suitable instrumentation for laser-accelerated proton (ion) beams is critical for development of integrated, laser-driven ion accelerator systems. Instrumentation aimed at beam diagnostics and control must be applied to the driving laser pulse, the laser-plasma that forms at the target and the emergent proton (ion) bunch in a correlated way to develop these novel accelerators. This report is a brief overview of established diagnostic techniques and new developments based on material presented...

  4. Beam Tests of a Prototype Stripline Beam Position Monitoring System for the Drive Beam of the CLIC Two-beam Module at CTF3

    CERN Document Server

    Benot-Morell, Alfonso; Nappa, Jean-Marc; Vilalte, Sebastien; Wendt, Manfred

    2016-01-01

    In collaboration with LAPP and IFIC, two units of a prototype stripline Beam Position Monitor (BPM) for the CLIC Drive Beam (DB), and its associated readout electronics have been successfully installed and tested in the Two-Beam-Module (TBM) at the CLIC Test Facility 3 (CTF3) at CERN. This paper gives a short overview of the BPM system and presents the performance measured under different Drive Beam configurations.

  5. Implementation of visualization system for beam service time in RIBF

    International Nuclear Information System (INIS)

    Beam availability is one important factor affecting research productivity of accelerator facilities. In RI Beam Factory (RIBF), the beam availability is defined simply as the ratio of actual beam service time to scheduled beam service time. The availability was previously estimated based on the down time of beam service recorded in our log-books of the paper medium. However, manual estimation of actual beam service time has limitation in its accuracy especially in case of hardware trouble. Hence, in order to realize labor-saving and accurate recording of down time, we have developed a visualization system that automatically records down time by using insertion status of Faraday cups. Implementation of the system has been completed and the system has been successfully operated in recent beam services performed in RIBF. (author)

  6. Development of the beam extraction synchronization system at the Fermilab Booster

    International Nuclear Information System (INIS)

    The new beam extraction synchronization control system called “Magnetic Cogging” was developed at the Fermilab Booster and it replaces a system called “RF Cogging” as part of the Proton Improvement Plan (PIP).[1] The flux throughput goal for the PIP is 2.2×1017 protons per hour, which is double the present flux. The flux increase will be accomplished by doubling the number of beam cycles which, in turn, will double the beam loss in the Booster accelerator if nothing else is done. The Booster accelerates beam from 400 MeV to 8 GeV and extracts it to the Main Injector (MI) or Recycler Ring (RR). Cogging controls the beam extraction gap position which is created early in the Booster cycle and synchronizes the gap to the rising edge of the Booster extraction kicker and the MI/RR injection kicker. The RF Cogging system controls the gap position by changing only the radial position of the beam thus limiting the beam aperture and creating beam loss due to beam scraping. The Magnetic Cogging system controls the gap position with the magnetic field of the dipole correctors while the radial position feedback keeps the beam on a central orbit. Also with Magnetic Cogging the gap creation can occur earlier in the Booster cycle when the removed particles are at a lower energy. Thus Magnetic Cogging reduces the deposited energy of the lost particles (beam energy loss) and results in less beam loss activation. Energy loss was reduced by 40% by moving the gap creation energy from 700 MeV to 400 MeV when the Booster Cogging system was switched from RF Cogging to Magnetic Cogging in March 2015

  7. Development of the beam extraction synchronization system at the Fermilab Booster

    Science.gov (United States)

    Seiya, K.; Chaurize, S.; Drennan, C. C.; Pellico, W.; Sullivan, T.; Triplett, A. K.; Waller, A. M.

    2015-11-01

    The new beam extraction synchronization control system called "Magnetic Cogging" was developed at the Fermilab Booster and it replaces a system called "RF Cogging" as part of the Proton Improvement Plan (PIP).[1] The flux throughput goal for the PIP is 2.2×1017 protons per hour, which is double the present flux. The flux increase will be accomplished by doubling the number of beam cycles which, in turn, will double the beam loss in the Booster accelerator if nothing else is done. The Booster accelerates beam from 400 MeV to 8 GeV and extracts it to the Main Injector (MI) or Recycler Ring (RR). Cogging controls the beam extraction gap position which is created early in the Booster cycle and synchronizes the gap to the rising edge of the Booster extraction kicker and the MI/RR injection kicker. The RF Cogging system controls the gap position by changing only the radial position of the beam thus limiting the beam aperture and creating beam loss due to beam scraping. The Magnetic Cogging system controls the gap position with the magnetic field of the dipole correctors while the radial position feedback keeps the beam on a central orbit. Also with Magnetic Cogging the gap creation can occur earlier in the Booster cycle when the removed particles are at a lower energy. Thus Magnetic Cogging reduces the deposited energy of the lost particles (beam energy loss) and results in less beam loss activation. Energy loss was reduced by 40% by moving the gap creation energy from 700 MeV to 400 MeV when the Booster Cogging system was switched from RF Cogging to Magnetic Cogging in March 2015.

  8. Pascal software structures achieve definite control of the 24 MFTF sustaining neutral-beam power supplies

    International Nuclear Information System (INIS)

    Precise control of large, complex systems is not assured unless there is known to be no unintended interactions in the control system. The software controlling the sustaining neutral-beam power supplies of the Mirror Fusion Test Facility accomplishes this feat. The software structures comprise some 16,000 lines of commented Pascal code, distributed amoung 10 different tasks. Each task may control any of the 24 power supplies. All the tasks are strictly event-driven, and are not subject to any system mode. Since there is no global information in the software, we know that all the power supplies are controlled independently

  9. Development of fast beam-stop system using RF chopper

    International Nuclear Information System (INIS)

    To avoid heat damage and radioactivation by beam loss of the J-PARC accelerator, Machine Protection System (MPS) has been developed. Actually, high responsibility and high reliability have been achieved in J-PARC. Beam-stop method in addition to a way of RFQ OFF has been requested in order to avoid damage to the RFQ. Therefore, we have been developing a fast beam-stop system by using a RF chopper. The fast beam-stop system, including beam test, is described in this paper. (author)

  10. Controls and Beam Diagnostics for Therapy-Accelerators

    CERN Document Server

    Eickhoff, H

    2000-01-01

    During the last four years GSI has developed a new procedure for cancer treatment by means of the intensity controlled rasterscan-method. This method includes active variations of beam parameters during the treatment session and the integration of 'on-line' PET monitoring. Starting in 1997 several patients have been successfully treated within this GSI experimental cancer treatment program; within this program about 350 patients shall be treated in the next 5 years. The developments and experiences of this program accompanied by intensive discussions with the medical community led to a proposal for a hospital based light ion accelerator facility for the clinic in Heidelberg. An essential part for patients treatments is the measurement of the beam properties within acceptance and constancy tests and especially for the rasterscan method during the treatment sessions. The presented description of the accelerator controls and beam diagnostic devices mainly covers the requests for the active scanning method, which...

  11. Improved beam spot measurements in the 2nd generation proton beam writing system

    International Nuclear Information System (INIS)

    Nanosized ion beams (especially proton and helium) play a pivotal role in the field of ion beam lithography and ion beam analysis. Proton beam writing has shown lithographic details down to the 20 nm level, limited by the proton beam spot size. Introducing a smaller spot size will allow smaller lithographic features. Smaller probe sizes, will also drastically improve the spatial resolution for ion beam analysis techniques. Among many other requirements, having an ideal resolution standard, used for beam focusing and a reliable focusing method, is an important pre-requisite for sub-10 nm beam spot focusing. In this paper we present the fabrication processes of a free-standing resolution standard with reduced side-wall projection and high side-wall verticality. The resulting grid is orthogonal (90.0° ± 0.1), has smooth edges with better than 6 nm side-wall projection. The new resolution standard has been used in focusing a 2 MeV H2+ beam in the 2nd generation PBW system at Center for Ion Beam Applications, NUS. The beam size has been characterized using on- and off-axis scanning transmission ion microscopy (STIM) and ion induced secondary electron detection, carried out with a newly installed micro channel plate electron detector. The latter has been shown to be a realistic alternative to STIM measurements, as the drawback of PIN diode detector damage is alleviated. With these improvements we show reproducible beam focusing down to 14 nm

  12. Expert system to control a fusion energy experiment

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, R.R.; Canales, T.; Lager, D.

    1986-01-01

    This paper describes a system that automates neutral beam source conditioning. The system achieves this with artificial intelligence techniques by encoding the behavior of several experts as a set of if-then rules in an expert system. One of the functions of the expert system is to control an adaptive controller that, in turn, controls the neutral beam source. The architecture of the system is presented followed by a description of its performance.

  13. Expert system to control a fusion energy experiment

    International Nuclear Information System (INIS)

    This paper describes a system that automates neutral beam source conditioning. The system achieves this with artificial intelligence techniques by encoding the behavior of several experts as a set of if-then rules in an expert system. One of the functions of the expert system is to control an adaptive controller that, in turn, controls the neutral beam source. The architecture of the system is presented followed by a description of its performance

  14. RFI hydrogen beam source system for materials testing

    International Nuclear Information System (INIS)

    A Radio Frequency Induction (RFI) ion source system has been designed, constructed and tested for integration as a fast rise time (≅100μsec), long pulse to CW heat source for the Sandia National Laboratories Plasma and Materials Test Facility (PMTF). The ion source system to be described is capable of producing a 40kV, 20A hydrogen beam and providing a uniform heat flux of up to 2.0 kWatt/cm/sup 2/ at targets, with areas in excess of 100cm/sup 2/, located ≅4. meters from the accelerator. An intense plasma is produced in the RFI ion source by inductive coupling of RF energy at a frequency of 1.5MHz to plasma electrons which are collisionally heated and maintain the discharge. Since no hot cathode structures are required with this plasma production techniques, source impurities are reduced and system control and reliability is enhanced. Source current density and extracted beam current is determined for a given source geometry, solely by the quantity of RF power coupled to the source. The beam current is thus controlled by the amplitude to the low level oscillator feeding the PA. Previous RFI sources we have built have been operated to extractable hydrogen or deuterium current densities of up to 500mA/cm/sup 2/ and have provided measured beam species fractions of 72/17/11% for H/sup +//H/sub 2//sup +//H/sub 3//sup +/, respectively, during 80k Volt extraction tests at LBL

  15. ALFA Detector Control System

    CERN Document Server

    Oleiro Seabra, Luis Filipe; The ATLAS collaboration

    2015-01-01

    ALFA (Absolute Luminosity For ATLAS) is one of the sub-detectors of ATLAS (A Toroidal LHC Apparatus). The ALFA system is composed by four stations installed in the LHC tunnel 240 m away from the ATLAS interaction point. Each station has a vacuum and ventilation system, movement control and all the required electronics for signal processing. The Detector Control System (DCS) provides control and monitoring of several components and ensures the safe operation of the detector contributing to good Data Quality. This paper describes the ALFA DCS system including a detector overview, operation aspects and hardware control through a SCADA system, WinCC OA.

  16. ALFA Detector Control System

    CERN Document Server

    Oleiro Seabra, Luis Filipe; The ATLAS collaboration

    2015-01-01

    ALFA (Absolute Luminosity For ATLAS) is one of the sub-detectors of ATLAS/LHC. The ALFA system is composed by two stations installed in the LHC tunnel 240 m away from each side of the ATLAS interaction point. Each station has a vacuum and ventilation system, movement control and all the required electronic for signal processing. The Detector Control System (DCS) provides control and monitoring of several components and ensures the safe operation of the detector contributing to good Data Quality. This paper describes the ALFA DCS system including a detector overview, operation aspects and hardware control through a SCADA system, WinCC OA.

  17. Beam extraction system in AIC-144 automatic isochronous cyclotron

    International Nuclear Information System (INIS)

    Project of beam extraction system in Cracow AIC-144 cyclotron is described. The problems of increase of beam emittance, and change of the magnetic field in the cyclotron chamber are discussed. Expected extraction coefficient of the beam is about 0.7. (S.B.)

  18. Beam characterisation of the KIRAMS electron microbeam system

    International Nuclear Information System (INIS)

    An electron microbeam system has been installed at the Korea Inst. of Radiological and Medical Sciences (KIRAMS) for use in radiation biology studies. The electron beam is produced from a commercial electron gun, and the beam size is defined by a 5 μm diameter pinhole. Beam energy can be varied in the range of 1-100 keV, covering a range of linear energy transfer from 0.4 to 12.1 keV μm-1. The micrometer-sized electron beam selectively irradiates cells cultured in a Mylar-bottomed dish. The positioning of target cells one by one onto the beam exit is automated, as is beam shooting. The electron beam entering the target cells has been calibrated using a Passivated Implanted Planar Silicon (PIPS) detector. This paper describes the KIRAMS microbeam cell irradiation system and its beam characteristics. (authors)

  19. Commissioning and Initial Performance of the LHC Beam-Based Feedback Systems

    CERN Document Server

    Boccardi, A; Calvo Giraldo, E; Denz, R; Gasior, M; Gonzalez, JL; Jackson, S; Jensen, LK; Jones, OR; King, Q; Kruk, G; Lamont, M; Page, S; Steinhagen, RJ; Wenninger, J

    2010-01-01

    The LHC deploys a comprehensive suite of beam-based feedbacks for safe and reliable machine operation. This contribution summarises the commissioning and early results of the LHC feedback control systems on orbit, tune, chromaticity, and energy. Their performance – strongly linked to the associated beam instrumentation, external beam perturbation sources and optics uncertainties – is evaluated and compared with the initial feedback design assumptions

  20. A matrix theory of the motion of an ellipsoidal bunch in a beam control system with a rectlinear optical axis and with space charge

    International Nuclear Information System (INIS)

    The motion of a 3-dimensional ellipsoidal bunch of charged particles in an arbitrary external electromagnetic field is considered taking into account the effect of space charge. The first approximation of the electromagnetic field within the bunch due to space charge has been found. The nonlinear matrix equation in the envelope variable space is written. An effective recursive computational method for the solution of the nonlinear beam envelope evolution is proposed

  1. Development of Adaptive Feedback Control System of Both Spatial and Temporal Beam Shaping for UV-Laser Light Source for RF Gun

    CERN Document Server

    Tomizawa, H; Dewa, H; Hanaki, H; Kobayashi, T; Mizuno, A; Suzuki, S; Taniuchi, T; Yanagida, K

    2004-01-01

    The ideal spatial and temporal profiles of a shot-by-shot single laser pulse are essential to suppress the emittance growth of the electron beam from a photo-cathode rf gun. We have been developing highly qualified UV-laser pulse as a light source of the rf gun for an injector candidate of future light sources. The gun cavity is a single-cell pillbox, and the copper inner wall is used as a photo cathode. The electron beam was accelerated up to 4.1 MeV at the maximum electric field on the cathode surface of 175 MV/m. For emittance compensation, two solenoid coils were used. As the first test run, with a microlens array as a simple spatial shaper, we obtained a minimum emittance value of 2 π·mm·mrad with a beam energy of 3.1 MeV, holding its charge to 0.1 nC/bunch. In the next test run, we prepared a deformable mirror for spatial shaping, and a spatial light modulator based on fused-silica plates for temporal shaping. We applied the both adaptive optics to automatically shape the bot...

  2. The LCLS Undulator Beam Loss Monitor Readout System

    Energy Technology Data Exchange (ETDEWEB)

    Dusatko, John; Browne, M.; Fisher, A.S.; Kotturi, D.; Norum, S.; Olsen, J.; /SLAC

    2012-07-23

    The LCLS Undulator Beam Loss Monitor System is required to detect any loss radiation seen by the FEL undulators. The undulator segments consist of permanent magnets which are very sensitive to radiation damage. The operational goal is to keep demagnetization below 0.01% over the life of the LCLS. The BLM system is designed to help achieve this goal by detecting any loss radiation and indicating a fault condition if the radiation level exceeds a certain threshold. Upon reception of this fault signal, the LCLS Machine Protection System takes appropriate action by either halting or rate limiting the beam. The BLM detector consists of a PMT coupled to a Cherenkov radiator located near the upstream end of each undulator segment. There are 33 BLMs in the system, one per segment. The detectors are read out by a dedicated system that is integrated directly into the LCLS MPS. The BLM readout system provides monitoring of radiation levels, computation of integrated doses, detection of radiation excursions beyond set thresholds, fault reporting and control of BLM system functions. This paper describes the design, construction and operational performance of the BLM readout system.

  3. Energy harvesting from controlled buckling of piezoelectric beams

    Science.gov (United States)

    Ansari, M. H.; Karami, M. Amin

    2015-11-01

    A piezoelectric vibration energy harvester is presented that can generate electricity from the weight of passing cars or crowds. The energy harvester consists of a piezoelectric beam, which buckles when the device is stepped on. The energy harvester can have a horizontal or vertical configuration. In the vertical (direct) configuration, the piezoelectric beam is vertical and directly sustains the weight of the vehicles or people. In the horizontal (indirect) configuration, the vertical weight is transferred to a horizontal axial force through a scissor-like mechanism. Buckling of the beam results in significant stresses and, thus, large power production. However, if the beam’s buckling is not controlled, the beam will fracture. To prevent this, the axial deformation is constrained to limit the deformations of the beam. In this paper, the energy harvester is analytically modeled. The considered piezoelectric beam is a general non-uniform beam. The natural frequencies, mode shapes, and the critical buckling force corresponding to each mode shape are calculated. The electro-mechanical coupling and the geometric nonlinearities are included in the model. The design criteria for the device are discussed. It is demonstrated that a device, realized with commonly used piezoelectric patches, can generate tens of milliwatts of power from passing car traffic. The proposed device could also be implemented in the sidewalks or integrated in shoe soles for energy generation. One of the key features of the device is its frequency up-conversion characteristics. The piezoelectric beam undergoes free vibrations each time the weight is applied to or removed from the energy harvester. The frequency of the free vibrations is orders of magnitude larger than the frequency of the load. The device is, thus, both efficient and insensitive to the frequency of the force excitations.

  4. The CERN SPS Control System

    CERN Multimedia

    CERN Neyrac Films

    2012-01-01

    Part of the series of films produced by CERN about the SPS. Names, facts and credits added on the 1975 version by Bengt Sagnell, Meyrin, Oct 2012. The project leader for the SPS accelerator (with 400 staff) was John Adams - later Sir John. The group responsible for the design and installation of the control system was led by Michael Crowley-Milling. 00:02:14 Bernard Sutton00:02:48 Michael Crowley-Milling, Head of the Controls Group00:03:01 Designed in the Controls Group, this was probably the first use of touch screens in an industrial control system00:04:37 Louis Burnod, Section leader, Beam Instrumentation00:05:36 Claes Frisk, Computer technician 00:06:03 The system contained 24 Norsk Data NORD-10 16-bit mini computers with 16-64 kB of magnetic core memory and external hard disks of from 5MB to 256 MB in size00:06:23 Frank Beck, Section leader, Central Controls00:06:26 Véronique Frammery, Programmer 00:06:31 Hans-Karl Kuhn, Power Supply Controls00:07:55 Raymond Rausch, Control electronics00:10:23 Paul Acti...

  5. Temperature Controlled Cathode Heating in Electron Beam Welding Machine

    Czech Academy of Sciences Publication Activity Database

    Horáček, Miroslav; Dupák, Jan

    2001-01-01

    Roč. 62, 2-3 (2001), s. 165-169. ISSN 0042-207X R&D Projects: GA AV ČR IBS2065015 Institutional research plan: CEZ:AV0Z2065902 Keywords : Electron beam welding machine * cathode heating * temperature control Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 0.541, year: 2001

  6. A modular control system

    International Nuclear Information System (INIS)

    The main objective of the modular control system is to provide the requirements to most of the processes supervision and control applications within the industrial automatization area. The design is based on distribution, modulation and expansion concepts. (Author)

  7. Motion control systems

    CERN Document Server

    Sabanovic, Asif

    2011-01-01

    "Presents a unified approach to the fundamental issues in motion control, starting from the basics and moving through single degree of freedom and multi-degree of freedom systems In Motion Control Systems, Šabanovic and Ohnishi present a unified approach to very diverse issues covered in motion control systems, offering know-how accumulated through work on very diverse problems into a comprehensive, integrated approach suitable for application in high demanding high-tech products. It covers material from single degree of freedom systems to complex multi-body non-redundant and redundant systems. The discussion of the main subject is based on original research results and will give treatment of the issues in motion control in the framework of the acceleration control method with disturbance rejection technique. This allows consistent unification of different issues in motion control ranging from simple trajectory tracking to topics related to haptics and bilateral control without and with delay in the measure...

  8. An electrostatic beam rocking system on the Surrey nuclear microprobe

    International Nuclear Information System (INIS)

    The use of two sets of magnetic dipoles, producing opposite fields, to rock a focused MeV ion beam over the surface of a crystalline sample is now well established in several nuclear microprobe laboratories. Such a 'beam rocking' system allows ion channeling analysis from micron-size regions of the sample to be measured, with a beam displacement over the sample surface as small as a few microns, and no requirements for an automated goniometer. While magnetic beam rocking systems are ideal for many applications, they are limited in the speed at which the beam can be rocked in angle owing to hysteresis effects. This may also cause problems of non-reproducibility of the beam displacement on a micron scale. Also, heavier ions are more difficult to rock through a given angle using a magnetic beam rocking system, whereas an electrostatic beam rocking system gives a rocking angle which is independent of the ion mass. This paper describes the construction and uses of a fast electrostatic beam rocking system, which uses two sets of high voltage plates driven in opposition at high frequencies. Ion optics simulations are used to model the performance of the system. The optics of this beam rocking system, in which both sets of deflection plates are located before the quadruplet lens formation are discussed. The uses of this system to rapidly image the location of crystal planes and axes, and to carry out rapid channeling analysis are presented

  9. Applied Control Systems Design

    CERN Document Server

    Mahmoud, Magdi S

    2012-01-01

    Applied Control System Design examines several methods for building up systems models based on real experimental data from typical industrial processes and incorporating system identification techniques. The text takes a comparative approach to the models derived in this way judging their suitability for use in different systems and under different operational circumstances. A broad spectrum of control methods including various forms of filtering, feedback and feedforward control is applied to the models and the guidelines derived from the closed-loop responses are then composed into a concrete self-tested recipe to serve as a check-list for industrial engineers or control designers. System identification and control design are given equal weight in model derivation and testing to reflect their equality of importance in the proper design and optimization of high-performance control systems. Readers’ assimilation of the material discussed is assisted by the provision of problems and examples. Most of these e...

  10. Particle beam injector system and method

    Science.gov (United States)

    Guethlein, Gary

    2013-06-18

    Methods and devices enable coupling of a charged particle beam to a radio frequency quadrupole accelerator. Coupling of the charged particle beam is accomplished, at least in-part, by relying on of sensitivity of the input phase space acceptance of the radio frequency quadrupole to the angle of the input charged particle beam. A first electric field across a beam deflector deflects the particle beam at an angle that is beyond the acceptance angle of the radio frequency quadrupole. By momentarily reversing or reducing the established electric field, a narrow portion of the charged particle beam is deflected at an angle within the acceptance angle of the radio frequency quadrupole. In another configuration, beam is directed at an angle within the acceptance angle of the radio frequency quadrupole by the first electric field and is deflected beyond the acceptance angle of the radio frequency quadrupole due to the second electric field.

  11. Implementation of the DIAC control system

    International Nuclear Information System (INIS)

    DIAC (Daejeon Ion Accelerator Complex) system was developed, and operated at JAEA of Japan by KEK team with a name of TRIAC (Tokai Radioactive Ion Accelerator Complex) during 2004 to 2010. The TRIAC control system was based on LabView and had two independent control units for ion source and accelerator. To be an efficient system, it is necessary to have an integrated control capability. And the control software, which had implemented by using LabView at TRIAC, will be changed with EPICS in order to give an effective beam service to the users. In this presentation, the old TRIAC control system is described, and a new control system for DIAC is discussed. The control system of DIAC is based on TRIAC. But it is gradually improved performance using EPICS toolkits and changing some digital interface hardware of it. Details of the control system will be demonstrated during the conference

  12. Control and optimization system

    Science.gov (United States)

    Xinsheng, Lou

    2013-02-12

    A system for optimizing a power plant includes a chemical loop having an input for receiving an input parameter (270) and an output for outputting an output parameter (280), a control system operably connected to the chemical loop and having a multiple controller part (230) comprising a model-free controller. The control system receives the output parameter (280), optimizes the input parameter (270) based on the received output parameter (280), and outputs an optimized input parameter (270) to the input of the chemical loop to control a process of the chemical loop in an optimized manner.

  13. The ILC control system

    International Nuclear Information System (INIS)

    Since the last ICALEPCS, a small multi-region team has developed a reference design model for a control system for the International Linear Collider as part of the ILC Global Design Effort. The scale and performance parameters of the ILC accelerator require new thinking in regards to control system design. Technical challenges include the large number of accelerator systems to be controlled, the large scale of the accelerator facility, the high degree of automation needed during accelerator operations, and control system equipment requiring 'Five Nines' availability. The R and D path for high availability touches the control system hardware, software, and overall architecture, and extends beyond traditional interfaces into the technical systems. Software considerations for HA include fault detection through exhaustive out-of-band monitoring and automatic state migration to redundant systems, while the telecom industry's emerging ATCA standard - conceived, specified, and designed for High Availability - is being evaluated for suitability for ILC front-end electronics.

  14. Design of optic system for 500 keV/10 mA electron beam machine

    International Nuclear Information System (INIS)

    In the 1995/1996 Research Year design of Electron Beam Machine components i.e. : Electron Source, High Voltage Supply, Accelerator Tube, Focussing System, Steering System, Scanning System, Vacuum System, Radiation Facility and Conveyer System also Electronics and Control System was carried out. This paper describes the design of Focussing, Steering and Scanning System. The Focussing System was an iron sheathed solenoid the Steering System was two sets of electromagnet placed perpendicular each other and the Scanning System was a set of alternating current electromagnet. The first Focussing System was designed to have 1 m focus distance for electron beam of 10 keV energy the second Focussing System was designed to have 1 m focus distance for electron beam of 1 MeV energy, the Steering System was designed to have 30o deflection angle for electron beam of 1 MeV energy and the Scanning System was designed to have 120 cm deflection distance and 20o deflection angle for electron beam of 1 MeV. Using these systems the 500 keV/10 mA Electron Beam Machine could be controlled. (author)

  15. Interaction between beam control and rf feedback loops for high Q cavities an heavy beam loading. Revision A

    International Nuclear Information System (INIS)

    An open-loop state space model of all the major low-level rf feedback control loops is derived. The model has control and state variables for fast-cycling machines to apply modern multivariable feedback techniques. A condition is derived to know when exactly we can cross the boundaries between time-varying and time-invariant approaches for a fast-cycling machine like the Low Energy Booster (LEB). The conditions are dependent on the Q of the cavity and the rate at which the frequency changes with time. Apart from capturing the time-variant characteristics, the errors in the magnetic field are accounted in the model to study the effects on synchronization with the Medium Energy Booster (MEB). The control model is useful to study the effects on beam control due to heavy beam loading at high intensities, voltage transients just after injection especially due to time-varying voltages, instability thresholds created by the cavity tuning feedback system, cross coupling between feedback loops with and without direct rf feedback etc. As a special case we have shown that the model agrees with the well known Pedersen model derived for the CERN PS booster. As an application of the model we undertook a detailed study of the cross coupling between the loops by considering all of them at once for varying time, Q and beam intensities. A discussion of the method to identify the coupling is shown. At the end a summary of the identified loop interactions is presented

  16. The upgraded rf system for the AGS and high intensity proton beams

    Energy Technology Data Exchange (ETDEWEB)

    Brennan, J.M. [Brookhaven National Lab., Upton, NY (United States). AGS Dept.

    1995-05-01

    The AGS has been upgraded over the past three years to produce a record beam intensity of 6 {times} 10{sup 13} protons per pulse for the fixed-target physics program. The major elements of the upgrade are: the new 1.5 GeV Booster synchrotron, the main magnet power supply, a high frequency longitudinal dilution cavity, a feedback damper for transverse instabilities, a fast gamma transition jump system, and a new high-power rf system. The new rf system and its role in achieving the high intensity goal are the subjects of this report. The rf system is heavily beam loaded, with 7 Amps of rf current in the beam and a peak power of 0.75 MW delivered to the beam by ten cavities. As an example of the scale of beam loading, at one point in the acceleration cycle the cavities are operated at 1.5 kV/gap; whereas, were it not for the new power amplifiers, the beam-induced voltage on the cavities would be over 25 kV/gap. The upgraded rf system, comprising: new power amplifiers, wide band rf feedback, improved cavities, and new low-level beam control electronics, is described. Results of measurements with beam, which characterize the system`s performance, are presented. A typical high intensity acceleration cycle is described with emphasis on the key challenges of beam loading.

  17. Human response to individually controlled micro environment generated with localized chilled beam

    DEFF Research Database (Denmark)

    Uth, Simon C.; Nygaard, Linette; Bolashikov, Zhecho Dimitrov;

    2014-01-01

    Indoor environment in a single-office room created by a localised chilled beam with individual control of the primary air flow was studied. Response of 24 human subjects when exposed to the environment generated by the chilled beam was collected via questionnaires under a 2-hour exposure including...... different work tasks at three locations in the room. Response of the subjects to the environment generated with a chilled ceiling combined with mixing air distribution was used for comparison. The air temperature in the room was kept at 26 or 28 °C. Results show no significant difference in the overall and...... local thermal sensation reported by the subjects with the two systems. Both systems were equally acceptable. At 26°C the individual control of the localised chilled beam lead to higher acceptability of the work environment. At 28°C the acceptability decreased with the two systems. It was not acceptable...

  18. Nonlinear control via approximate input-output linearization - The ball and beam example

    Science.gov (United States)

    Hauser, John; Sastry, Shankar; Kokotovic, Petar

    1992-01-01

    A study is made of approximate input-output linearization of nonlinear systems which fail to have a well defined relative degree. For such systems, a method is provided for constructing approximate systems that are input-output linearizable. The analysis presented in this note is motivated through its application to a common undergraduate control laboratory experiment, the ball and beam system, where it is shown to be more effective for trajectory tracking than the standard Jacobian linearization.

  19. Demonstration of the importance of a dedicated neutron beam monitoring system for BNCT facility.

    Science.gov (United States)

    Chao, Der-Sheng; Liu, Yuan-Hao; Jiang, Shiang-Huei

    2016-01-01

    The neutron beam monitoring system is indispensable to BNCT facility in order to achieve an accurate patient dose delivery. The neutron beam monitoring of a reactor-based BNCT (RB-BNCT) facility can be implemented through the instrumentation and control system of a reactor provided that the reactor power level remains constant during reactor operation. However, since the neutron flux in reactor core is highly correlative to complicated reactor kinetics resulting from such as fuel depletion, poison production, and control blade movement, some extent of variation may occur in the spatial distribution of neutron flux in reactor core. Therefore, a dedicated neutron beam monitoring system is needed to be installed in the vicinity of the beam path close to the beam exit of the RB-BNCT facility, where it can measure the BNCT beam intensity as closely as possible and be free from the influence of the objects present around the beam exit. In this study, in order to demonstrate the importance of a dedicated BNCT neutron beam monitoring system, the signals originating from the two in-core neutron detectors installed at THOR were extracted and compared with the three dedicated neutron beam monitors of the THOR BNCT facility. The correlation of the readings between the in-core neutron detectors and the BNCT neutron beam monitors was established to evaluate the improvable quality of the beam intensity measurement inferred by the in-core neutron detectors. In 29 sampled intervals within 16 days of measurement, the fluctuations in the mean value of the normalized ratios between readings of the three BNCT neutron beam monitors lay within 0.2%. However, the normalized ratios of readings of the two in-core neutron detectors to one of the BNCT neutron beam monitors show great fluctuations of 5.9% and 17.5%, respectively. PMID:26595774

  20. Torque control system

    Science.gov (United States)

    Studenick, D. K.; Tyler, A. L.; Squillari, W.

    1975-01-01

    System stabilizes aximuth of gondolas which are carried by high-altitude balloons as platforms for tracking telescopes. When telescopes must be constantly aimed at specific targets, control system stabilizes gondola to within 5 arc-seconds.

  1. A Labview based FPGA data acquisition with integrated stage and beam transport control

    International Nuclear Information System (INIS)

    We report on a new FPGA based data acquisition system developed for the CSIRO Nuclear Microprobe (NMP) which is tightly integrated with both target positioning and beam transport. The data acquisition system called MicrodaQ is based on National Instruments Labview FPGA and numerous instrumentation modules spread over several PC’s. Beam transport uses a feedback control loop to optimise current on target for long unmanned experiments. These upgrades are discussed in detail and an example of the systems use for μ-Particle Induced X-ray Emission (PIXE) analysis on a Doriri apatite is briefly described

  2. Discrete control systems

    CERN Document Server

    Okuyama, Yoshifumi

    2014-01-01

    Discrete Control Systems establishes a basis for the analysis and design of discretized/quantized control systemsfor continuous physical systems. Beginning with the necessary mathematical foundations and system-model descriptions, the text moves on to derive a robust stability condition. To keep a practical perspective on the uncertain physical systems considered, most of the methods treated are carried out in the frequency domain. As part of the design procedure, modified Nyquist–Hall and Nichols diagrams are presented and discretized proportional–integral–derivative control schemes are reconsidered. Schemes for model-reference feedback and discrete-type observers are proposed. Although single-loop feedback systems form the core of the text, some consideration is given to multiple loops and nonlinearities. The robust control performance and stability of interval systems (with multiple uncertainties) are outlined. Finally, the monograph describes the relationship between feedback-control and discrete ev...

  3. Upgrade of kek linac control network system

    International Nuclear Information System (INIS)

    KEK Linac has been supplying a stable beam to the ring four different. In order to provide a highly available beam over a long period of time, a stable network communication between the server computer and the local control device is essential. By the Great East Japan Earthquake of 2011, part of the network system were damaged. Further, because it promotes the advancement of injector toward SuperKEKB, was performed updates to the network system with high reliability and high performance. In this paper, I will report more information about network monitoring system and update of network system. (author)

  4. The upgraded rf system for the AGS and high intensity proton beams

    International Nuclear Information System (INIS)

    The AGS has been upgraded over the past three years to produce a record beam intensity of 6 x 1013 protons per pulse for the fixed-target physics program. The major elements of the upgrade are: the new 1.5 GeV Booster synchrotron, the main magnet power supply, a high frequency longitudinal dilution cavity, a feedback damper for transverse instabilities, a fast gamma transition jump system, and a new high-power rf system. The new rf system and its role in achieving the high intensity goal are the subjects of this report. The rf system is heavily beam loaded, with 7 Amps of rf current in the beam and a peak power of 0.75 MW delivered to the beam by ten cavities. As an example of the scale of beam loading, at one point in the acceleration cycle the cavities are operated at 1.5 kV/gap; whereas, were it not for the new power amplifiers, the beam-induced voltage on the cavities would be over 25 kV/gap. The upgraded rf system, comprising: new power amplifiers, wide band rf feedback, improved cavities, and new low-level beam control electronics, is described. Results of measurements with beam, which characterize the system's performance, are presented. A typical high intensity acceleration cycle is described with emphasis on the key challenges of beam loading

  5. SPS/LEP beam transfer equipment control using industrial automation components

    International Nuclear Information System (INIS)

    Several control systems for SPS and LEP beam transfer equipment have to be commissioned in the near future. Tools for fast software development, easy maintenance and modifications, compliance with industrial standards, and independence of specific suppliers are considered to be essential. A large fraction of the systems can be realized using off-the-shelf industrial automation components like industrial I/O systems, programmable logic controllers, or diskless PCs. Specific electronics built up in G-64 can be integrated. Diskless systems running UNIX and X Windows are foreseen as process controllers and local access media. (author)

  6. Control system design guide

    Energy Technology Data Exchange (ETDEWEB)

    Sellers, David; Friedman, Hannah; Haasl, Tudi; Bourassa, Norman; Piette, Mary Ann

    2003-05-01

    The ''Control System Design Guide'' (Design Guide) provides methods and recommendations for the control system design process and control point selection and installation. Control systems are often the most problematic system in a building. A good design process that takes into account maintenance, operation, and commissioning can lead to a smoothly operating and efficient building. To this end, the Design Guide provides a toolbox of templates for improving control system design and specification. HVAC designers are the primary audience for the Design Guide. The control design process it presents will help produce well-designed control systems that achieve efficient and robust operation. The spreadsheet examples for control valve schedules, damper schedules, and points lists can streamline the use of the control system design concepts set forth in the Design Guide by providing convenient starting points from which designers can build. Although each reader brings their own unique questions to the text, the Design Guide contains information that designers, commissioning providers, operators, and owners will find useful.

  7. BeamOptics : a Symbolic Platform for Modeling and the Solution of Beam Optics System

    International Nuclear Information System (INIS)

    BeamOptics [1] is a Mathematica-based computing platform devoted to the following objectives: (1) Structured representation and manipulation of particle beam optics systems with symbolic capabilities, (2) Analytical and numerical modeling of beam optics system behaviors, (3) Solution to specific beam optical or general accelerator system problems, in algebraic form in certain cases, through customized algorithms. Taking advantage of and conforming to the highly formal and self-contained structure of Mathematica, BeamOptics provides a unique platform for developing accelerator design and analysis programs. The feature of symbolic computation and the ability to manipulate the beam optics system at the programming language level enable the user to solve or optimize his system with considerably more efficiency, rigour and insight than can be easily achieved with passive modeling or numerical simulation methods. BeamOptics is developed with continuous evolution in mind. New features and algorithms from diverse sources can be incorporated without major modification, due to its formal and generic structure. In this report, a survey is given of the basic structure and methodology of BeamOptics, as well as a demonstration of some of its more specialized applications, and possible direction of evolution

  8. Spacecraft momentum control systems

    CERN Document Server

    Leve, Frederick A; Peck, Mason A

    2015-01-01

    The goal of this book is to serve both as a practical technical reference and a resource for gaining a fuller understanding of the state of the art of spacecraft momentum control systems, specifically looking at control moment gyroscopes (CMGs). As a result, the subject matter includes theory, technology, and systems engineering. The authors combine material on system-level architecture of spacecraft that feature momentum-control systems with material about the momentum-control hardware and software. This also encompasses material on the theoretical and algorithmic approaches to the control of space vehicles with CMGs. In essence, CMGs are the attitude-control actuators that make contemporary highly agile spacecraft possible. The rise of commercial Earth imaging, the advances in privately built spacecraft (including small satellites), and the growing popularity of the subject matter in academic circles over the past decade argues that now is the time for an in-depth treatment of the topic. CMGs are augmented ...

  9. Control system of ATF

    International Nuclear Information System (INIS)

    A computer control system of Accelerator Test Facility(ATF) is described in detail. The ATF presently consists of 60MeV electron injector linac and two klystron Lest stands, and is controlled by a workstation computer with CAMAC interfaces. For its nature of R and D accelerator aimed to realize TeV region linear collider, the control system also should have a flexibility in both hardware and software. Programmable sequence controllers are introduced in the electron gun system and klystron modulator systems and their performances are tested. The control software which is coded using FORTRAN consists in many independent programs. Each program can access to full functions of a specified device or can control the function which is common to many devices

  10. Phase control and beam steering of semiconductor laser arrays

    Science.gov (United States)

    Katz, J.

    1982-01-01

    The operational principles and a possible device configuration of one dimensional monolithically integrated semiconductor laser arrays are described. The output beam of the array can be electronically steered. Devices of the type can find applications in optical communication systems where the power levels needed are above the capability of a single laser device.

  11. Mead photovoltaic system controller

    Energy Technology Data Exchange (ETDEWEB)

    Millner, A.R.

    1979-01-31

    A system controller has been designed, built, tested, and in operation for one year at MIT/Lincoln Laboratory's 25-kW-peak Solar Photovoltaic Power System located at Mead, Nebraska. The controller allows the site to operate without human intervention, and has brought to light some of the problems of charge-control algorithms in a deep-discharge environment.

  12. Interlock system of electron beam machine GJ-2

    International Nuclear Information System (INIS)

    As an irradiation installation facility, the electron beam machine (EBM) irradiation facility which use radionuclide as radiation source. There are three safety aspects to be considered in the facility i.e the safeties for human, machines, and samples to be irradiated. The safety aspect for human is to the radiation hazard and the safety aspect for machine and sample is to the damage as the result of operating failure. In the EBM GJ-2 (made in China) twelve interlock system parameter are installed to keep all of the safety aspects. Each interlock system consist transducer that controls a certain switch, a magnetic relay, and visible and audible interlock indicators to improve the reliability of interlock systems a method called redundancy method is applied to the systems of operation of high voltage. (author)

  13. Modeling and control of a two-axis fast steering mirror with piezoelectric stack actuators for laser beam tracking

    Science.gov (United States)

    Zhu, Wei; Bian, Leixiang; An, Yi; Chen, Gangli; Rui, Xiaoting

    2015-07-01

    This paper outlines an optical beam steering system built using a two-axis fast steering mirror (FSM) with piezoelectric stack actuators to maintain precise pointing control. A novel mathematical model of the FSM is put forward by using a transfer matrix method of a multibody system to describe the dynamics characteristics and a hysteresis model to represent the hysteresis. Based on the proposed model, a model-based hybrid control is applied to force the output angle of the FSM to track the laser beam accurately thereafter. The experimental results are in accordance with the theoretical analysis. The results highlight significantly improved accuracy in the beam tracking control of the FSM.

  14. Common Control System Vulnerability

    Energy Technology Data Exchange (ETDEWEB)

    Trent Nelson

    2005-12-01

    The Control Systems Security Program and other programs within the Idaho National Laboratory have discovered a vulnerability common to control systems in all sectors that allows an attacker to penetrate most control systems, spoof the operator, and gain full control of targeted system elements. This vulnerability has been identified on several systems that have been evaluated at INL, and in each case a 100% success rate of completing the attack paths that lead to full system compromise was observed. Since these systems are employed in multiple critical infrastructure sectors, this vulnerability is deemed common to control systems in all sectors. Modern control systems architectures can be considered analogous to today's information networks, and as such are usually approached by attackers using a common attack methodology to penetrate deeper and deeper into the network. This approach often is composed of several phases, including gaining access to the control network, reconnaissance, profiling of vulnerabilities, launching attacks, escalating privilege, maintaining access, and obscuring or removing information that indicates that an intruder was on the system. With irrefutable proof that an external attack can lead to a compromise of a computing resource on the organization's business local area network (LAN), access to the control network is usually considered the first phase in the attack plan. Once the attacker gains access to the control network through direct connections and/or the business LAN, the second phase of reconnaissance begins with traffic analysis within the control domain. Thus, the communications between the workstations and the field device controllers can be monitored and evaluated, allowing an attacker to capture, analyze, and evaluate the commands sent among the control equipment. Through manipulation of the communication protocols of control systems (a process generally referred to as ''reverse engineering''), an

  15. A closed-loop photon beam control study for the Advanced Light Source

    International Nuclear Information System (INIS)

    The third generation Advanced Light Source (ALS) will produce extremely bright photon beams using undulators and wigglers. In order to position the photon beams accurate to the micron level, a closed-loop feedback system is being developed. Using photon position monitors and dipole corrector magnets, a closed-loop system can automatically compensate for modeling uncertainties and exogenous disturbances. The following paper will present a dynamics model for the perturbations of the closed orbit of the electron beam in the ALS storage ring including the vacuum chamber magnetic field penetration effects. Using this reference model, two closed-loop feedback algorithms will be compared -- a classical PI controller and a two degree-of-freedom approach. The two degree-of-freedom method provides superior disturbance rejection while maintaining the desired performance goals. Both methods will address the need to gain schedule the controller due to the time varying dynamics introduced by changing field strengths when scanning the insertion devices

  16. Fast control and data acquisition in the neutral beam test facility

    Energy Technology Data Exchange (ETDEWEB)

    Luchetta, A., E-mail: adriano.luchetta@igi.cnr.it; Manduchi, G.; Taliercio, C.

    2014-05-15

    Highlights: • The paper describes the fast control and data acquisition in the ITER neutral beam test facility. • The usage of real time control in ion beam generation and extraction is proposed. • Real time management of breakdowns is described. • The implementation of event-driven data acquisition is reported. - Abstract: Fast control and data acquisition are required in the ion source test bed of the ITER neutral beam test facility, referred to as SPIDER. Fast control will drive the operation of the power supply systems with particular reference to special asynchronous events, such as the breakdowns. These are short-circuits among grids or between grids and vessel that can occur repeatedly during beam operation. They are normal events and, as such, they will be managed by the fast control system. Cycle time associated to such fast control is down to hundreds of microseconds. Fast data acquisition is required when breakdowns occur. Event-driven data acquisition is triggered in real time by fast control at the occurrence of each breakdown. Pre- and post-event samples are acquired, allowing capturing information on transient phenomena in a whole time-window centered on the event. Sampling rate of event-driven data acquisition is up to 5 MS/s. Fast data acquisition may also be independent of breakdowns as in the case of the cavity ring-down spectroscopy where data chunks are acquired at 100 MS/s in bursts of 1.5 ms every 100 ms and are processed in real time to produce derived measurements. The paper after the description of the SPIDER fast control and data acquisition application will report the system design based on commercially available hardware and the MARTe and MDSplus software frameworks. The results obtained by running a full prototype of the fast control and data acquisition system are also reported and discussed. They demonstrate that all SPIDER fast control and data acquisition requirements can be met in the prototype solution.

  17. Fast control and data acquisition in the neutral beam test facility

    International Nuclear Information System (INIS)

    Highlights: • The paper describes the fast control and data acquisition in the ITER neutral beam test facility. • The usage of real time control in ion beam generation and extraction is proposed. • Real time management of breakdowns is described. • The implementation of event-driven data acquisition is reported. - Abstract: Fast control and data acquisition are required in the ion source test bed of the ITER neutral beam test facility, referred to as SPIDER. Fast control will drive the operation of the power supply systems with particular reference to special asynchronous events, such as the breakdowns. These are short-circuits among grids or between grids and vessel that can occur repeatedly during beam operation. They are normal events and, as such, they will be managed by the fast control system. Cycle time associated to such fast control is down to hundreds of microseconds. Fast data acquisition is required when breakdowns occur. Event-driven data acquisition is triggered in real time by fast control at the occurrence of each breakdown. Pre- and post-event samples are acquired, allowing capturing information on transient phenomena in a whole time-window centered on the event. Sampling rate of event-driven data acquisition is up to 5 MS/s. Fast data acquisition may also be independent of breakdowns as in the case of the cavity ring-down spectroscopy where data chunks are acquired at 100 MS/s in bursts of 1.5 ms every 100 ms and are processed in real time to produce derived measurements. The paper after the description of the SPIDER fast control and data acquisition application will report the system design based on commercially available hardware and the MARTe and MDSplus software frameworks. The results obtained by running a full prototype of the fast control and data acquisition system are also reported and discussed. They demonstrate that all SPIDER fast control and data acquisition requirements can be met in the prototype solution

  18. Drone Control System

    Science.gov (United States)

    1983-01-01

    Drones, subscale vehicles like the Firebees, and full scale retired military aircraft are used to test air defense missile systems. The DFCS (Drone Formation Control System) computer, developed by IBM (International Business Machines) Federal Systems Division, can track ten drones at once. A program called ORACLS is used to generate software to track and control Drones. It was originally developed by Langley and supplied by COSMIC (Computer Software Management and Information Center). The program saved the company both time and money.

  19. Magnetic spectrometer control system

    International Nuclear Information System (INIS)

    The design and implementation of a new computerized control system for the several devices of the magnetic spectrometer at TANDAR Laboratory is described. This system, as a main difference from the preexisting one, is compatible with almost any operating systems of wide spread use available in PC. This allows on-line measurement and control of all signals from any terminal of a computer network. (author)

  20. Beam shaping in high-power laser systems with using refractive beam shapers

    Science.gov (United States)

    Laskin, Alexander; Laskin, Vadim

    2012-06-01

    Beam Shaping of the spatial (transverse) profile of laser beams is highly desirable by building optical systems of high-power lasers as well in various applications with these lasers. Pumping of the crystals of Ti:Sapphire lasers by the laser radiation with uniform (flattop) intensity profile improves performance of these ultrashort pulse high-power lasers in terms of achievable efficiency, peak-power and stability, output beam profile. Specifications of the solid-state lasers built according to MOPA configuration can be also improved when radiation of the master oscillator is homogenized and then is amplified by the power amplifier. Features of building these high power lasers require that a beam shaping solution should be capable to work with single mode and multimode beams, provide flattop and super-Gauss intensity distributions, the consistency and divergence of a beam after the intensity re-distribution should be conserved and low absorption provided. These specific conditions are perfectly fulfilled by the refractive field mapping beam shapers due to their unique features: almost lossless intensity profile transformation, low output divergence, high transmittance and flatness of output beam profile, extended depth of field, adaptability to real intensity profiles of TEM00 and multimode laser sources. Combining of the refractive field mapping beam shapers with other optical components, like beam-expanders, relay imaging lenses, anamorphic optics makes it possible to generate the laser spots of necessary shape, size and intensity distribution. There are plenty of applications of high-power lasers where beam shaping bring benefits: irradiating photocathode of Free Electron Lasers (FEL), material ablation, micromachining, annealing in display making techniques, cladding, heat treating and others. This paper will describe some design basics of refractive beam shapers of the field mapping type, with emphasis on the features important for building and applications

  1. System control and communication

    International Nuclear Information System (INIS)

    Rapid and ongoing development in the energy sector has consequences for system control at all levels. In relation to system control and communication the control system is challenged in five important ways: 1) Expectations for security of supply, robustness and vulnerability are becoming more stringent, and the control system plays a big part in meeting these expectations. 2) Services are becoming increasingly based on markets that involve the transmission system operators (TSOs), generators and distribution companies. Timely, accurate and secure communication is essential to the smooth running of the markets. 3) Adding large amounts of renewable energy (RE) to the mix is a challenge for control systems because of the intermittent availability of many RE sources. 4) Increasing the number of active components in the system, such as small CHP plants, micro-CHP and intelligent loads, means that the system control will be much more complex. 5) In the future it is likely that power, heat, gas, transport and communication systems will be tighter coupled and interact much more. (au)

  2. Study of Electron Beam Curing Process Using Epoxy Resin System

    International Nuclear Information System (INIS)

    The competition among industries in the current globalization system has required a systematic cost reduction without affecting the quality of the final product. This fact has encouraged the use of new technologies application on productive process, especially on polymeric composites, to assure the competitiveness. The possibility of producing a new type of carbon fiber reinforced composite by radiation process with excellent thermal and mechanical properties, has been researched since 90's and it can be a potential application in aerospace, marine and automobile industries. The polymeric composites cured by thermal process (furnace or autoclave) are an example of long curing cycles, which requires time and energy consumption. Electron beam curing technology allows the process at room temperature and reduces curing time; consequently, it becomes the main difference of this technology over thermal curing process. The aim of this work was to study electron beam curable epoxy formulation for filament winding process, as well as to investigate the electron beam curing process parameters using a DC 1500/25 - Job 188 Dynamitron model linear accelerator as radiation source, with 0.5 to 1.5 MeV, 0.1 to 25 mA and 60 to 120 cm scanning electron beam. The resin system consists of commercial epoxy resin (diglycidyl ether of bisphenol A - DGEBA) and cationic initiator (diaryliodonium hexafluoantimonate) and the polymerization carried out at room temperature with controlled dose rate. Thermal post cure took part of the process to improve the degree of cure and glass transition temperature (Tg) similar to thermal curable resin properties

  3. The control system

    International Nuclear Information System (INIS)

    The present control system has matured both in terms of age and capacity. Thus a new system based on a local area network (LAN) is being developed. A pilot project has been started but, owing to difficulties encountered with the present operating system used with the microprocessors, it has become necessary to reconsider the choice of operating system. A recently-released multi-tasking operating system that runs on the existing hardware has been chosen. 1 fig

  4. Connection for dose rate control of betatron gamma beam

    International Nuclear Information System (INIS)

    The connection is based on a single-channel controller consisting of a microcomputer which prior to the start of control will find the region of the absolute maximum dose rate of the betatron gamma beam. In the course of control it will evaluate data on the level of dose rate from the betatron, and on the basis of a comparison of the previous and current condition will change the moment of injecting electrons into the acceleration chamber by one step. The control algorithm is described. The heating cathode current of the injection gun is adjusted manually. The controller may be connected to the betatron without any adjustments to the control console. The described connection allows to achieve good stability of maximum dose rate values. (J.B.). 2 figs

  5. Aspects of input processing in the numerical control of electron beam machines

    International Nuclear Information System (INIS)

    A high-performance Numerical Control has been developed for an Electron Beam Machine. The system is structured into 3 hierarchial levels: Input Processing, Realtime Processing (such as Geometry Interpolation) and the Interfaces to the Electron Beam Machine. The author considers the Input Processing. In conventional Numerical Controls the Interfaces to the control is given by the control language as defined in DIN 66025. State of the art in NC-technology offers programming systems of differing competence covering the spectra between manual programming in the control language to highly sophisticated systems such as APT. This software interface has been used to define an Input Processor that in cooperation with the Hostcomputer meets the requirements of a sophisticated NC-system but at the same time provides a modest stand-alone system with all the basic functions such as interactive program-editing, program storage, program execution simultaneous with the development of another program, etc. Software aspects such as adapting DIN 66025 for Electron Beam Machining, organisation and modularisation of Input Processor Software has been considered and solutions have been proposed. Hardware aspects considered are interconnections of the Input Processor with the Host and the Realtime Processors. Because of economical and development-time considerations, available software and hardware has been liberally used and own development has been kept to a minimum. The proposed system is modular in software and hardware and therefore very flexible and open-ended to future expansion. (Auth.)

  6. The CEBAF control system

    International Nuclear Information System (INIS)

    CEBAF has recently upgraded its accelerator control system to use EPICS, a control system toolkit being developed by a collaboration among laboratories in the US and Europe. The migration to EPICS has taken place during a year of intense commissioning activity, with new and old control systems operating concurrently. Existing CAMAC hardware was preserved by adding a CAMAC serial highway link to VME; newer hardware developments are now primarily in VME. Software is distributed among three tiers of computers: first, workstations and X terminals for operator interfaces and high level applications; second, VME single board computers for distributed access to hardware and for local control processing; third, embedded processors where needed for faster closed loop operation. This system has demonstrated the ability to scale EPICS to controlling thousands of devices, including hundreds of embedded processors, with control distributed among dozens of VME processors executing more than 125,000 EPICS database records. To deal with the large size of the control system, CEBAF has integrated an object oriented database, providing data management capabilities for both low level I/O and high level machine modeling. A new callable interface which is control system independent permits access to live EPICS data, data in other Unix processes, and data contained in the object oriented database

  7. ISTTOK control system upgrade

    International Nuclear Information System (INIS)

    Highlights: •ISTTOK fast controller. •All real-time diagnostic and actuators were integrated in the control platform. •100 μs control cycle under the MARTe framework. •The ISTTOK control system upgrade provides reliable operation with an improved operational space. -- Abstract: The ISTTOK tokamak (Ip = 4 kA, BT = 0.5 T, R = 0.46 m, a = 0.085 m) is one of the few tokamaks with regular alternate plasma current (AC) discharges scientific programme. In order to improve the discharge stability and to increase the number of AC discharge cycles a novel control system was developed. The controller acquires data from 50 analog-to-digital converter (ADC) channels of real-time diagnostics and measurements: tomography, Mirnov coils, interferometer, electric probes, sine and cosine probes, bolometer, current delivered by the power supplies, loop voltage and plasma current. The system has a control cycle of 100 μs during which it reads all the diagnostics connected to the advanced telecommunications computing architecture (ATCA) digitizers and sends the control reference to ISTTOK actuators. The controller algorithms are executed on an Intel® Q8200 chip with 4 cores running at 2.33 GHz and connected to the I/O interfaces through an ATCA based environment. The real-time control system was programmed in C++ on top of the Multi-threaded Application Real-Time executor (MARTe). To extend the duration of the AC discharges and the plasma stability a new magnetising field power supply was commissioned and the horizontal and vertical field power supplies were also upgraded. The new system also features a user-friendly interface based on HyperText Markup Language (HTML) and Javascript to configure the controller parameters. This paper presents the ISTTOK control system and the consequent update of real-time diagnostics and actuators

  8. ISTTOK control system upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, Ivo S., E-mail: ivoc@ipfn.ist.utl.pt; Duarte, Paulo; Fernandes, Horácio; Valcárcel, Daniel F.; Carvalho, Pedro J.; Silva, Carlos; Duarte, André S.; Neto, André; Sousa, Jorge; Batista, António J.N.; Carvalho, Bernardo B.

    2013-10-15

    Highlights: •ISTTOK fast controller. •All real-time diagnostic and actuators were integrated in the control platform. •100 μs control cycle under the MARTe framework. •The ISTTOK control system upgrade provides reliable operation with an improved operational space. -- Abstract: The ISTTOK tokamak (Ip = 4 kA, BT = 0.5 T, R = 0.46 m, a = 0.085 m) is one of the few tokamaks with regular alternate plasma current (AC) discharges scientific programme. In order to improve the discharge stability and to increase the number of AC discharge cycles a novel control system was developed. The controller acquires data from 50 analog-to-digital converter (ADC) channels of real-time diagnostics and measurements: tomography, Mirnov coils, interferometer, electric probes, sine and cosine probes, bolometer, current delivered by the power supplies, loop voltage and plasma current. The system has a control cycle of 100 μs during which it reads all the diagnostics connected to the advanced telecommunications computing architecture (ATCA) digitizers and sends the control reference to ISTTOK actuators. The controller algorithms are executed on an Intel{sup ®} Q8200 chip with 4 cores running at 2.33 GHz and connected to the I/O interfaces through an ATCA based environment. The real-time control system was programmed in C++ on top of the Multi-threaded Application Real-Time executor (MARTe). To extend the duration of the AC discharges and the plasma stability a new magnetising field power supply was commissioned and the horizontal and vertical field power supplies were also upgraded. The new system also features a user-friendly interface based on HyperText Markup Language (HTML) and Javascript to configure the controller parameters. This paper presents the ISTTOK control system and the consequent update of real-time diagnostics and actuators.

  9. Load Control System Reliability

    Energy Technology Data Exchange (ETDEWEB)

    Trudnowski, Daniel [Montana Tech of the Univ. of Montana, Butte, MT (United States)

    2015-04-03

    This report summarizes the results of the Load Control System Reliability project (DOE Award DE-FC26-06NT42750). The original grant was awarded to Montana Tech April 2006. Follow-on DOE awards and expansions to the project scope occurred August 2007, January 2009, April 2011, and April 2013. In addition to the DOE monies, the project also consisted of matching funds from the states of Montana and Wyoming. Project participants included Montana Tech; the University of Wyoming; Montana State University; NorthWestern Energy, Inc., and MSE. Research focused on two areas: real-time power-system load control methodologies; and, power-system measurement-based stability-assessment operation and control tools. The majority of effort was focused on area 2. Results from the research includes: development of fundamental power-system dynamic concepts, control schemes, and signal-processing algorithms; many papers (including two prize papers) in leading journals and conferences and leadership of IEEE activities; one patent; participation in major actual-system testing in the western North American power system; prototype power-system operation and control software installed and tested at three major North American control centers; and, the incubation of a new commercial-grade operation and control software tool. Work under this grant certainly supported the DOE-OE goals in the area of “Real Time Grid Reliability Management.”

  10. Recent Improvements to the Control of the CTF3 High-Current Drive Beam

    CERN Document Server

    Constance, B; Gamba, D; Skowronski, P K

    2013-01-01

    In order to demonstrate the feasibility of the CLIC multiTeV linear collider option, the drive beam complex at the CLIC Test Facility (CTF3) at CERN is providing highcurrent electron pulses for a number of related experiments. By means of a system of electron pulse compression and bunch frequency multiplication, a fully loaded, 120 MeV linac is used to generate 140 ns electron pulses of around 28 Amperes. Subsequent deceleration of this high-current drive beam demonstrates principles behind the CLIC acceleration scheme, and produces 12 GHz RF power for experimental purposes. As the facility has progressed toward routine operation, a number of studies aimed at improving the drive beam performance have been carried out. Additional feedbacks, automated steering programs, and improved control of optics and dispersion have contributed to a more stable, reproducible drive beam with consequent benefits for the experiments.

  11. Sharing control system software

    International Nuclear Information System (INIS)

    Building a custom accelerator control system requires effort in the range of 30-100 person-years. This represents a significant investment of time, effort, and risk, as well as challenges for management. Even when the system is successful, the software has not yet been applied to the particular project; no custom control algorithms, either engineering or physics-based, have been implemented; and the system has not been documented for long-term maintenance and use. This paper reviews the requirements for sharing software between accelerator control system projects. It also reviews the three mechanisms by which control system software has been shared in the past and is being shared now, as well as some of the experiences. After reviewing the mechanisms and experiences, one can conclude there is no one best solution. The right software sharing mechanism depends upon the needs of the client site, the client resources available, and the services the provider can give

  12. RHIC beam permit and quench detection communications system

    International Nuclear Information System (INIS)

    A beam permit module has been developed to concentrate RHIC, subsystem sensor outputs, permit beam, and initiate emergency shutdowns. The modules accept inputs from the vacuum, cryogenic, power supply, beam loss, and superconducting magnet quench detection systems. Modules are located at equipment locations around the RHIC ring. The modules are connected by three fiberoptic communications links; a beam permit link, and two magnet power supply interlock links. During operation, carrier presence allows beam. If a RHIC subsystem detects a fault, the beam permit carrier terminates - initiating a beam dump. If the fault was a superconducting magnet quench, a power supply interlock carrier terminates - initiating an emergency magnet power dump. In addition, the master module triggers an event to cause remote sensors to log and hold data at the time-of-failure

  13. ROV Motion Control Systems

    OpenAIRE

    Dukan, Fredrik

    2014-01-01

    This thesis is about automatic motion control systems for remotely operated vehicles (ROV). The work has focused on topics within guidance and navigation. In addition, a motion control system has been developed, implemented, tested and used on two ROVs in sea trials.The main motivation for the work has been the need to automate ROV tasks in order to make the ROV a more efficient tool for exploring the ocean space. Many parts of a motion control system for a ROV is similar to that of surface v...

  14. Control system integration

    CERN Document Server

    Shea, T J

    2008-01-01

    This lecture begins with a definition of an accelerator control system, and then reviews the control system architectures that have been deployed at the larger accelerator facilities. This discussion naturally leads to identification of the major subsystems and their interfaces. We shall explore general strategies for integrating intelligent devices and signal processing subsystems based on gate arrays and programmable DSPs. The following topics will also be covered: physical packaging; timing and synchronization; local and global communication technologies; interfacing to machine protection systems; remote debugging; configuration management and source code control; and integration of commercial software tools. Several practical realizations will be presented.

  15. LHC Beam Dump System: Analysis of beam commissioning, performance and the consequences of abnormal operation

    CERN Document Server

    Kramer, Thomas

    2011-01-01

    The LHC accelerates proton beams to a momentum of up to 7 TeV/c. At this energy level and with nominal beam intensity the stored energy of 360 MJ per beam is sufficient to melt 500 kg of copper. In addition up to 10 GJ are stored within the LHC magnet system at top energy. It is obvious that such a machine needs well designed safety and protection systems. The LHC Beam Dump System (LBDS) is such a system and one of the most critical once concerning machine protection and safe operation. It is used to dispose of high intensity beams between 450 GeV and 7 TeV and is thus designed to fast extract beam in a loss free way and to transfer it to an external absorber. For each ring systems of 15 horizontal fast kicker magnets (MKD), 15 vertically deflecting magnetic septa (MSD) and 10 diluter kicker magnets (MKB) are installed. This thesis is concerned with the analysis of the LBDS performance under normal operating parameters as well as under abnormal conditions like in the event of asynchronous beam abort or missin...

  16. Medium and high energy electron beam processing system

    International Nuclear Information System (INIS)

    Electron Beam Processing System (EPS) is a useful and powerful tool for industrial irradiation process. The specification of EPS is decided by consideration to irradiate what material with how thick and wide, how much dose, how to handle, in what atmosphere. In designing an EPS, it is necessary to consider safety measure such as x-ray shielding, ozone control and interlock system. The initial costs to install typical EPS are estimated for acceleration voltages from 500 kV to 5 MV, including following items; those are electron beam machine, x-ray shielding, auxiliary equipment, material handling, survey for installation, ozone exhaust duct, cooling water system, wiring and piping. These prices are reference only because the price should be changed for each case. The price of x-ray shielding should be changed by construction cost. Auxiliary equipment includes window, cooling blower, ozone exhaust blower and SF6 gas handling equipment. In installation work at site, actual workers of 3 - 4 persons for 2 months are necessary. Material handling system is considered only rolls provided in the shielding room as reference. In addition to the initial installation, operators and workers may be required to wear a personal radiation monitor. An x-ray monitor of suitable design should be installed outside the shield room to monitor x-ray level in the working area. (Y. Tanaka)

  17. Present state of the MAMI control system

    International Nuclear Information System (INIS)

    MAMI (Mainz Microtron) is an electron accelerator consisting of a cascade of three race-track microtrons, with an output electron beam of 855 MeV and 100 μA cw. The first two stages (output energy 180 MeV) were operative for nuclear-physics experiments from 1983 to 1987 and have since been transferred to a new building. They will serve as an injector for the third stage, now under construction. The control system for MAMI was based on a versatile process communication software system for a network of processors with multiprocess operating systems. This system has previously proved very successful, so we decided to rely on it as control system for the new, upgraded accelerator, replacing the control computers (instead of two HP1000s, now one MicroVAX-II) and making several changes and extensions. We strictly unified the communication interface to the processes. Accordingly, a set of display, steering, measuring and optimization processes can be used in a flexible manner: for example, emittance measurements at several points of the beam line and automatic beam-position optimization in the beam line and in the microtrons. Using a portable compiler generator, we were able to develop a BASIC-like interpreter for high-level control purposes in a very short time (one man-month). In addition to the MicroVAX we are planning to operate other processors as well (VME and single-board computers), coupled via Ethernet, using our communication software. (orig.)

  18. Control systems under attack?

    CERN Document Server

    Lüders, Stefan

    2005-01-01

    The enormous growth of the Internet during the last decade offers new means to share and distribute both information and data. In Industry, this results in a rapprochement of the production facilities, i.e. their Process Control and Automation Systems, and the data warehouses. At CERN, the Internet opens the possibility to monitor and even control (parts of) the LHC and its four experiments remotely from anywhere in the world. However, the adoption of standard IT technologies to Distributed Process Control and Automation Systems exposes inherent vulnerabilities to the world. The Teststand On Control System Security at CERN (TOCSSiC) is dedicated to explore the vulnerabilities of arbitrary Commercial-Of-The-Shelf hardware devices connected to standard Ethernet. As such, TOCSSiC should discover their vulnerabilities, point out areas of lack of security, and address areas of improvement which can then be confidentially communicated to manufacturers. This paper points out risks of accessing the Control and Automa...

  19. Adding PCs to SLC Control System

    International Nuclear Information System (INIS)

    The SLAC Controls Department has interfaced IBM-Compatible PCs to the SLC Control System, for use by the Final Focus Test Beam (FFTB) experimenters, who are building new accelerator equipment and developing and testing it at their home institutions. They will bring the equipment to SLAC and integrate it into the control system using a new software package. The machine physicists and operators will use the existing SLC control system applications and database device types to control and monitor the equipment. The PCs support a limited control environment: they run DOS and exchange messages with the existing control system via TCP/IP over ethernet, using the new SLC Area Message Service. This mechanism will also allow SLC to implement other commercial device controllers that can communicate over ethernet and run the same software interface code

  20. Infrared free electron laser magnet power supply control system

    International Nuclear Information System (INIS)

    An infrared free-electron laser (IR-FEL) is under development at Materials and Advanced Accelerator Sciences Division, RRCAT, Indore, for the investigation of materials using an electron beam. This system consists of a 90 keV electron gun as an electron source, a linear accelerator (LINAC) which accelerates the beam to energy in the range of 15-25 MeV, beam transport line and an undulator. Beam transport line consists of dipoles, quadrupoles and steering magnets for transporting beam from the LINAC exit to the entrance of the undulator. In this paper we are presenting the development of control system for these precision power supplies

  1. Reset Control Systems

    CERN Document Server

    Baños, Alfonso

    2012-01-01

    Reset Control Systems addresses the analysis for reset control treating both its basic form which requires only that the state of the controller be reinitialized to zero (the reset action) each time the tracking error crosses zero (the reset condition), and some useful variations of the reset action (partial reset with fixed or variable reset percentage) and of the reset condition (fixed or variable reset band and anticipative reset). The issues regarding reset control – concepts and motivation; analysis tools; and the application of design methodologies to real-world examples – are given comprehensive coverage. The text opens with an historical perspective which moves from the seminal work of the Clegg integrator and Horowitz FORE to more recent approaches based on impulsive/hybrid control systems and explains the motivation for reset compensation. Preliminary material dealing with notation, basic definitions and results, and with the definition of the control problem under study is also included. The fo...

  2. Control and Information Systems

    Directory of Open Access Journals (Sweden)

    Jiri Zahradnik

    2003-01-01

    Full Text Available The article deals with main tends of scientific research activities of Department of Control and Information Systems at the Faculty of Electrical Engineering of University of Zilina and its perspectives in this area.

  3. Mimicking the cochlear amplifier in a cantilever beam using nonlinear velocity feedback control

    International Nuclear Information System (INIS)

    The mammalian cochlea exhibits a nonlinear amplification which allows mammals to detect a large range of sound pressure levels while maintaining high frequency sensitivity. This work seeks to mimic the cochlea’s nonlinear amplification in a mechanical system. A nonlinear, velocity-based feedback control law is applied to a cantilever beam with piezoelectric actuators. The control law reduces the linear viscous damping of the system while introducing a cubic damping term. The result is a system which is positioned close to a Hopf bifurcation. Modelling and experimental results show that the beam with this control law undergoes a one-third amplitude scaling near the resonance frequency and an amplitude-dependent bandwidth. Both behaviors are characteristic of data obtained from the mammalian cochlea. This work could provide insight on the biological cochlea while producing bio-inspired sensors with a large dynamic range and sharp frequency sensitivity. (papers)

  4. Advanced access control system

    International Nuclear Information System (INIS)

    A prototype voice verification system has been installed which provides the required positive identification at the main site access control point. This system compares an individual's file voice print with a sample voice print obtained from the individual when an attempt is made to enter the site. The voice system transmits the individual's identify to a central processor. The system installed at the Barnwell Nuclear Fuel Plant is described

  5. The Epicure Control System

    International Nuclear Information System (INIS)

    The Epicure Control System supports the Fermilab fixed target physics program. The system is distributed across a network of many different types of components. The use of multiple layers on interfaces for communication between logical tasks fits the client-server model. Physical devices are read and controlled using symbolic references entered into a database with an editor utility. The database system consists of a central portion containing all device information and optimized portions distributed among many nodes. Updates to the database are available throughout the system within minutes after being requested

  6. Controllability of nilpotent systems

    International Nuclear Information System (INIS)

    The purpose of this paper is to investigate algebraic conditions which give information about the controllability of invariant control systems on nilpotent Lie groups. With the same purpose, the authors use the co-adjoint representation and define the concept of symplectic vectors. We study the existence of these objects to analyze the controllability. In particular, we obtain a characterization when G is simply connected. (author). 9 refs

  7. Reactor limit control system

    International Nuclear Information System (INIS)

    The very extensive use of limitations in the operational field between protection system and closed-loop controls is an important feature of German understanding of operational safety. The design of limitations is based on very large activities in the computational field but mostly on the high level of the plant-wide own commissioning experience of a turnkey contractor. Limitations combine intelligence features of closed-loop controls with the high availability of protection systems. (orig.)

  8. Beam interlock system and safe machine parameters system 2010 and beyond

    CERN Document Server

    Todd, B

    2010-01-01

    The Beam Interlock System (BIS) and Safe Machine Parameters (SMP) system are central to the protection of the Large Hadron Collider (LHC) machine. The BIS has been critical for the safe operation of LHC from the first day of operation. It has been installed and commissioned, only minor enhancements are required in order to accommodate all future LHC machine protection requirements. At reduced intensity, the SMP system is less critical for LHC operation. As such, the current system satisfies the 2010 operational requirements. Further developments are required, both at the SMP Controller level, and at the system level, in order to accommodate the requirements of the LHC beyond 2010.

  9. Adaptive Inflow Control System

    CERN Document Server

    Volkov, Vasily Y; Zhuravlev, Oleg N; Nukhaev, Marat T; Shchelushkin, Roman V

    2014-01-01

    This article presents the idea and realization for the unique Adaptive Inflow Control System being a part of well completion, able to adjust to the changing in time production conditions. This system allows to limit the flow rate from each interval at a certain level, which solves the problem of water and gas breakthroughs. We present the results of laboratory tests and numerical calculations obtaining the characteristics of the experimental setup with dual-in-position valves as parts of adaptive inflow control system, depending on the operating conditions. The flow distribution in the system was also studied with the help of three-dimensional computer model. The control ranges dependences are determined, an influence of the individual elements on the entire system is revealed.

  10. Business opportunities in the SSCL global control system

    International Nuclear Information System (INIS)

    The SSC consists of a series of six accelerators: an injector complex made up of a LINAC, a Low Energy Booster (LEB), a Medium Energy Booster (MEB), and High Energy Booster (HEB), as well as two storage rings together known as the open-quotes Collider.close quotes Although controls requirements and issues related to this complex of accelerators are not inherently different from those of other large accelerator laboratories, some special problems result from the large number of control points involved (greater than 500,000), the great distances between the various components (up to 100 Km), and the very high reliability required (0.986 availability for the global control system). The SSCL will employ an integrated control system, which at the highest level is called the Global Accelerator Control System (GACS). The GACS is defined as that system which provides the infrastructure and environment in which all systems directly affecting the accelerated beam are integrated, operated and controlled. The GACS is divided into two primary subsystems. Beam Controls and Process Controls. Beam Controls are those required to operate systems which directly support beam acceleration, steering, focusing and diagnostics. The precisely timed and synchronized, high speed, high quality Beam Controls are required only during beam operations. In contrast, the Process Controls operate independently, update at slower rates and do not require precise timing or synchronization

  11. Business opportunities in the SSCL Global Control System

    International Nuclear Information System (INIS)

    The SSC consists of a series of six accelerators: an injector complex made up of a LINAC, a Low Energy Booster (LEB), a Medium Energy Booster (MEB), and High Energy Booster (HEB), as well as two storage rings together known as the ''Collider.'' Although controls requirements and issues related to this complex of accelerators are not inherently different from those of other large accelerator laboratories, some special problems result from the large number of control points involved (greater than 500,000), the great distances between the various components (up to 100 Km), and the very high reliability required (.986 availability for the global control system). The SSCL will employ an integrated control system, which at the highest level is called the Global Accelerator Control System (GACS). The GACS is defined as that system which provides the infrastructure and environment in which all systems directly affecting the accelerated beam are integrated, operated and controlled. The GACS is divided into two primary subsystems, Beam Controls and Process Controls. Beam Controls are those required to operate systems which directly support beam acceleration, steering, focusing and diagnostics. The precisely timed and synchronized, high speed, high quality Beam Controls are required only during beam operations. In contrast, the Process Controls operate independently, update at slower and do not require precise timing or synchronization

  12. ROBUST POSITIONING OF LASER BEAMS USING PROPORTIONAL INTEGRAL DERIVATIVE AND BASED OBSERVER-FEEDBACK CONTROL

    OpenAIRE

    Kwabena A. Konadu; Sun Yi; Wonchang Choi; Taher Abu-Lebdeh

    2013-01-01

    High-precision positioning of laser beams has been a great challenge in industry due to inevitable existence of noise and disturbance. The work presented in this study addresses this problem by employing two different control strategies: Proportional Integral Derivative (PID) control and state feedback control with an observer. The control strategies are intended to stabilize the position of a laser beam on a Position Sensing Device (PSD) located on a Laser Beam Stabilization (or, laser beam ...

  13. Instrumentation for diagnostics and control of laser-accelerated proton (ion) beams.

    Science.gov (United States)

    Bolton, P R; Borghesi, M; Brenner, C; Carroll, D C; De Martinis, C; Fiorini, Francesca; Flacco, A; Floquet, V; Fuchs, J; Gallegos, P; Giove, D; Green, J S; Green, S; Jones, B; Kirby, D; McKenna, P; Neely, D; Nuesslin, F; Prasad, R; Reinhardt, S; Roth, M; Schramm, U; Scott, G G; Ter-Avetisyan, S; Tolley, M; Turchetti, G; Wilkens, J J

    2014-05-01

    Suitable instrumentation for laser-accelerated proton (ion) beams is critical for development of integrated, laser-driven ion accelerator systems. Instrumentation aimed at beam diagnostics and control must be applied to the driving laser pulse, the laser-plasma that forms at the target and the emergent proton (ion) bunch in a correlated way to develop these novel accelerators. This report is a brief overview of established diagnostic techniques and new developments based on material presented at the first workshop on 'Instrumentation for Diagnostics and Control of Laser-accelerated Proton (Ion) Beams' in Abingdon, UK. It includes radiochromic film (RCF), image plates (IP), micro-channel plates (MCP), Thomson spectrometers, prompt inline scintillators, time and space-resolved interferometry (TASRI) and nuclear activation schemes. Repetition-rated instrumentation requirements for target metrology are also addressed. PMID:24100298

  14. Design and Application of phased array radar beam control system%相控阵发雷达波束控制系统的设计与应用

    Institute of Scientific and Technical Information of China (English)

    王明辉

    2009-01-01

    相控阵雷达波束控制系统的主要功能是实现天线波束指向的定位控制.同时,该系统的性能优劣直接影响到雷迭的性能指标,所以其自身还应具备脱机检测和联机监测功能.本文重点讲述了采型号雷达的波束控制系统的设计原理及应用.%Steering the beam direction is the main function of beam steering system of phased array radar, besides, out-line-testing and online monitoring should be performed by itself because capability of this system directly influenced performance index of radar. It is mostly introduced in this paper that the design principle and application of beam steering system of certain type radar.

  15. Adaptive Model Predictive Vibration Control of a Cantilever Beam with Real-Time Parameter Estimation

    Directory of Open Access Journals (Sweden)

    Gergely Takács

    2014-01-01

    Full Text Available This paper presents an adaptive-predictive vibration control system using extended Kalman filtering for the joint estimation of system states and model parameters. A fixed-free cantilever beam equipped with piezoceramic actuators serves as a test platform to validate the proposed control strategy. Deflection readings taken at the end of the beam have been used to reconstruct the position and velocity information for a second-order state-space model. In addition to the states, the dynamic system has been augmented by the unknown model parameters: stiffness, damping constant, and a voltage/force conversion constant, characterizing the actuating effect of the piezoceramic transducers. The states and parameters of this augmented system have been estimated in real time, using the hybrid extended Kalman filter. The estimated model parameters have been applied to define the continuous state-space model of the vibrating system, which in turn is discretized for the predictive controller. The model predictive control algorithm generates state predictions and dual-mode quadratic cost prediction matrices based on the updated discrete state-space models. The resulting cost function is then minimized using quadratic programming to find the sequence of optimal but constrained control inputs. The proposed active vibration control system is implemented and evaluated experimentally to investigate the viability of the control method.

  16. Beam transfer functions and beam stabilisation in a double RF system

    CERN Document Server

    Shaposhnikova, Elena; Linnecar, Trevor Paul R

    2005-01-01

    The high intensity proton beam for LHC accelerated in the CERN SPS is stabilised against coupled-bunch instabilities by a 4th harmonic RF system in bunch-shortening mode. Bunch-lengthening mode, which could also be useful to reduce peak line density and alleviate problems from e-cloud and kicker heating, does not give desirable results for beam stability. In this paper an analysis of the limitations of these two different modes of operation is presented together with measurements of the Beam Transfer Function for the double RF system. As predicted by theory, for sufficiently long bunches with the same noise excitation, the measured amplitude of the beam response in bunchlengthening mode is an order of magnitude higher than that for bunch-shortening mode or for a single RF system.

  17. The ISOLDE control system

    Science.gov (United States)

    Deloose, I.; Pace, A.

    1994-12-01

    The two CERN isotope separators named ISOLDE have been running on the new Personal Computer (PC) based control system since April 1992. The new architecture that makes heavy use of the commercial software and hardware of the PC market has been implemented on the 1700 geographically distributed control channels of the two separators and their experimental area. Eleven MSDOS Intel-based PCs with approximately 80 acquisition and control boards are used to access the equipment and are controlled from three PCs running Microsoft Windows used as consoles through a Novell Local Area Network. This paper describes the interesting solutions found and discusses the reduced programming workload and costs that have been obtained.

  18. MFTF supervisory control system

    International Nuclear Information System (INIS)

    A computerized supervisory control system is being developed for the Mirror Fusion Test Facility. The system includes nine Perkin-Elmer 7/32 and 8/32 computers connected by a block of common core memory (128 kilobytes). The network is a disk designed for reliability and redundancy. If one computer goes down, the local-control micro-processors that it controls are switched to another computer in a matter of seconds. The control consoles permit operators to open and close valves, start or stop pumps, and adjust operating levels. The experiment is controlled by two superconsoles and five satellite consoles. The software, written in PASCAL, contains such subsystems as organizing the computers into a network, operating the consoles and accessing the data base

  19. FMIT facility control system

    International Nuclear Information System (INIS)

    The control system for the Fusion Materials Irradiation Test (FMIT) Facility, under construction at Richland, Washington, uses current techniques in distributed processing to achieve responsiveness, maintainability and reliability. Developmental experience with the system on the FMIT Prototype Accelerator (FPA) being designed at the Los Alamos National Laboratory is described as a function of the system's design goals and details. The functional requirements of the FMIT control system dictated the use of a highly operator-responsive, display-oriented structure, using state-of-the-art console devices for man-machine communications. Further, current technology has allowed the movement of device-dependent tasks into the area traditionally occupied by remote input-output equipment; the system's dual central process computers communicate with remote communications nodes containing microcomputers that are architecturally similar to the top-level machines. The system has been designed to take advantage of commercially available hardware and software

  20. Synchrotron Radiation Beam Line of Piezoelectric Monochromator Control

    International Nuclear Information System (INIS)

    It describes a Piezo Amplifier and Servo-controller module applied in the LN2-cooled Monochromator control system. The application of RS232 communication based on EPICS software environment and its software are implemented. (authors)

  1. CNEOST Control Software System

    Science.gov (United States)

    Wang, Xin; Zhao, Hai-bin; Xia, Yan; Lu, Hao; Li, Bin

    2016-01-01

    In 2013, CNEOST (China Near Earth Object Survey Telescope) adapted its hardware system for the new CCD camera. Based on the new system architecture, the control software is re-designed and implemented. The software system adopts the messaging mechanism based on the WebSocket protocol, and possesses good flexibility and expansibility. The user interface based on the responsive web design has realized the remote observations under both desktop and mobile devices. The stable operation of the software system has greatly enhanced the operation efficiency while reducing the complexity, and has also made a successful attempt for the future system design of telescope and telescope cloud.

  2. Beam position monitoring and feedback steering system at the photon factory

    International Nuclear Information System (INIS)

    A version of the beam steering servo system was used to vertically position and stabilize the synchrotron radiation beam at the Photon Factory. System components included a photon beam position monitor located 12 m from the bend magnet source point, a servo controller containing frequency compensation and gain circuits, and a 3-magnet orbital bump steering system. Two types of position monitor, one an ion chamber and the other on in-vacuum device, were used in the system. Vertical beam position noise spectra obtained from these monitors showed predominant peaks occurring at 14.5 Hz, 50 Hz, and at several other frequencies in the 1 to 100 Hz range. The closed-loop system was able to reduce low frequency positional offsets (< 0.1 Hz) by a factor of 1000, and the 14.5 Hz oscillation by a factor of 6

  3. Application of Energy Finite Element Method in Active Vibration Control of Piezoelectric Intelligent Beam

    Directory of Open Access Journals (Sweden)

    Jinhua Xie

    2012-01-01

    Full Text Available Based on the transmission and equilibrium relationship of vibration energy in beam-like structures, the Galerkin weighted residual method was applied to equation discretization. An equivalent transformation of feedback element was suggested to develop the Energy Finite Element model of a composite piezoelectric cantilever beam driven by harmonic excitation on lateral direction, with both systems with and without time delay being studied and the power input estimation of harmonic excitation was discussed for the resolution of Energy Finite Element function. Then the energy density solutions of the piezoelectric coupling beam through Energy Finite Element Method (EFEM and classical wave theory were compared to verify the EFEM model, which presented a good accordance. Further investigation was undertaken about the influence of control parameters including the feedback gain and arrangement of piezoelectric patches on characteristics of system energy density distribution.

  4. Transverse oscillations of an underwater beam-cable system

    OpenAIRE

    Blanco, Max; Wilson, P.A.

    2010-01-01

    An Autonomous Underwater Vehicle refuel station is proposed. The power source is located on board a surface vessel, while the AUV is serviced at depth. The structure which connects the two craft is modelled as a cable-beam. Transverse oscillations of this cable-beam system are investigated through a fourth-order differential equation.

  5. Mechanical engineering problems in the TFTR neutral beam system

    International Nuclear Information System (INIS)

    A conceptual design of a prototype beam line for the TFTR Neutral Beam System has been developed. The basic components have been defined, cost estimates prepared, and the necessary development programs identified. Four major mechanical engineering problems, potential solutions and the required development programs are discussed

  6. TMX magnet control system

    International Nuclear Information System (INIS)

    A control system utilizing a microcomputer has been developed that controls the power supplies driving the Tandem Mirror Experiment (TMX) magnet set and monitors magnet coil operation. The magnet set consists of 18 magnet coils that are driven by 26 dc power supplies. There are two possible modes of operation with this system: a pulse mode where the coils are pulsed on for several seconds with a dc power consumption of 16 MW; and a continuous mode where the coils can run steady state at 10 percent of maximum current ratings. The processor has been given an active control role and serves as an interface between the operator and electronic circuitry that controls the magnet power supplies. This microcomputer also collects and processes data from many analog singal monitors in the coil circuits and numerous status signals from the supplies. Placing the microcomputer in an active control role has yielded a compact, cost effective system that simplifies the magnet system operation and has proven to be very reliable. This paper will describe the TMX magnet control sytem and discuss its development

  7. A wire scanner system for characterizing the BNL energy recovery LINAC beam position monitor system

    Energy Technology Data Exchange (ETDEWEB)

    Michnoff R.; Biscardi, C.; Cerniglia, P.; Degen, C.; Gassner, D.; Hoff, L.; Hulsart, R.

    2012-04-15

    A stepper motor controlled wire scanner system has recently been modified to support testing of the Brookhaven National Laboratory (BNL) Collider-Accelerator department's Energy Recovery Linac (ERL) beam position monitor (BPM) system. The ERL BPM consists of four 9.33 mm diameter buttons mounted at 90 degree spacing in a cube with 1.875 inch inside diameter. The buttons were designed by BNL and fabricated by Times Microwave Systems. Libera brilliance single pass BPM electronic modules with 700 MHz bandpass filter, manufactured by Instrumentation Technologies, will be used to measure the transverse beam positions at 14 locations around the ERL. The wire scanner assembly provides the ability to measure the BPM button response to a pulsed wire, and evaluate and calibrate the Libera position measurement electronics. A description of the wire scanner system and test result data will be presented.

  8. Asynchronous interactive control systems

    Science.gov (United States)

    Vuskovic, M. I.; Heer, E.

    1980-01-01

    A class of interactive control systems is derived by generalizing interactive manipulator control systems. The general structural properties of such systems are discussed and an appropriate general software implementation is proposed. This is based on the fact that tasks of interactive control systems can be represented as a network of a finite set of actions which have specific operational characteristics and specific resource requirements, and which are of limited duration. This has enabled the decomposition of the overall control algorithm into a set of subalgorithms, called subcontrollers, which can operate simultaneously and asynchronously. Coordinate transformations of sensor feedback data and actuator set-points have enabled the further simplification of the subcontrollers and have reduced their conflicting resource requirements. The modules of the decomposed control system are implemented as parallel processes with disjoint memory space communicating only by I/O. The synchronization mechanisms for dynamic resource allocation among subcontrollers and other synchronization mechanisms are also discussed in this paper. Such a software organization is suitable for the general form of multiprocessing using computer networks with distributed storage.

  9. Conception and realisation of a system for the automatic alignment of a CO2 laser beam

    International Nuclear Information System (INIS)

    The present paper deals with the continuous control of the direction of a CO2 laser beam, with a view to laser machining. Slow deviations, due to the cavity instability, move away the beam from the focusing system axis. An automatic alignment device acting on the last flat mirror of the optical line has been designed. This mirror is actuated by 2 motors which vary its inclination in 2 directions x,y. The first part of the present paper deals with the alignment principle worked according to the specific constraints to be faced and to the characteristics of the beam. It uses the revolution symmetry of the energy distribution of the beam: 4 thermocouples surrounding the beam on a same circumference yield equals signals if the beam is centered onto the 4 sensors. An angular displacement is characterised by the difference between the signals of 2 opposed detectors. The second part presents the digital feedback system: the divergence or the beam is computed from the differential signal by a coefficient K experimentally valued. The motor commands proceed from optical geometry laws. The filtering of the thermocouple signals is necessary in order to sort the slowly changing signal related to the beam displacement, from the higher frequency signal related to the laser system instability. The system has been implemented on a 16 bit microprocessor. (author)

  10. The holographic optical micro-manipulation system based on counter-propagating beams

    International Nuclear Information System (INIS)

    We present a system employing a dynamic diffractive optical element to control properties of two counter-propagating beams overlapping within a sample chamber. This system allows us to eliminate optical aberrations along both beam pathways and arbitrarily switch between various numbers of laser beams and their spatial profiles (i.e. Gaussian, Laguerre-Gaussian, Bessel beams, etc.). We successfully tested various counter-propagating dual-beam configurations including optical manipulation of both high and low index particles in water or air, particle delivery in an optical conveyor belt and the formation of colloidal solitons by optical binding. Furthermore, we realized a novel optical mixer created by particles spiraling in counter-propagating interfering optical vortices and a new tool for optical tomography or localized spectroscopy enabling sterile contactless rotation and reorientation of a trapped living cell

  11. Initial investigation using statistical process control for quality control of accelerator beam steering

    OpenAIRE

    Able Charles M; Hampton Carnell J; Baydush Alan H; Munley Michael T

    2011-01-01

    Abstract Background This study seeks to increase clinical operational efficiency and accelerator beam consistency by retrospectively investigating the application of statistical process control (SPC) to linear accelerator beam steering parameters to determine the utility of such a methodology in detecting changes prior to equipment failure (interlocks actuated). Methods Steering coil currents (SCC) for the transverse and radial planes are set such that a reproducibly useful photon or electron...

  12. A novel beam focus control at the entrance to the ANU 14UD accelerator

    International Nuclear Information System (INIS)

    Tandem electrostatic accelerators often require the flexibility to operate at variety of terminal voltages to cater for various user needs. However beam transmission will only be optimal for a limited range of terminal voltages. This paper describes a focussing system that greatly expands the range of terminal voltages for optimal transmission. This is achieved by controlling the gradient of the entrance of the low-energy tube providing an additional controllable focusing element. Up to 150 kV is applied to the fifth electrode of the first unit of the accelerator tube giving control of the tube entrance lens strength. Beam tests to confirm the efficacy of the lens have been performed. These tests demonstrate that the entrance lens control eliminates the need to short out sections of the tube for low terminal voltage operation. (authors)

  13. A novel beam focus control at the entrance to the ANU 14UD accelerator

    Directory of Open Access Journals (Sweden)

    De Cesare M.

    2013-12-01

    Full Text Available Tandem electrostatic accelerators often require the flexibility to operate at variety of terminal voltages to cater for various user needs. However beam transmission will only be optimal for a limited range of terminal voltages. This paper describes a focussing system that greatly expands the range of terminal voltages for optimal transmission. This is achieved by controlling the gradient of the entrance of the low-energy tube providing an additional controllable focusing element. Up to 150 kV is applied to the fifth electrode of the first unit of the accelerator tube giving control of the tube entrance lens strength. Beam tests to confirm the efficacy of the lens have been performed. These tests demonstrate that the entrance lens control eliminates the need to short out sections of the tube for low terminal voltage operation.

  14. A novel beam focus control at the entrance to the ANU 14UD accelerator

    Science.gov (United States)

    De Cesare, M.; Weisser, D. C.; Fifield, L. K.; Tunningley, T. B.; Lobanov, N. R.

    2013-12-01

    Tandem electrostatic accelerators often require the flexibility to operate at variety of terminal voltages to cater for various user needs. However beam transmission will only be optimal for a limited range of terminal voltages. This paper describes a focussing system that greatly expands the range of terminal voltages for optimal transmission. This is achieved by controlling the gradient of the entrance of the low-energy tube providing an additional controllable focusing element. Up to 150 kV is applied to the fifth electrode of the first unit of the accelerator tube giving control of the tube entrance lens strength. Beam tests to confirm the efficacy of the lens have been performed. These tests demonstrate that the entrance lens control eliminates the need to short out sections of the tube for low terminal voltage operation.

  15. A Fuzzy Logic Based Controller for the Automated Alignment of a Laser-beam-smoothing Spatial Filter

    Science.gov (United States)

    Krasowski, M. J.; Dickens, D. E.

    1992-01-01

    A fuzzy logic based controller for a laser-beam-smoothing spatial filter is described. It is demonstrated that a human operator's alignment actions can easily be described by a system of fuzzy rules of inference. The final configuration uses inexpensive, off-the-shelf hardware and allows for a compact, readily implemented embedded control system.

  16. Control Systems with Friction

    OpenAIRE

    Olsson, Henrik

    1996-01-01

    Friction-related problems are frequently encountered in control systems. This thesis treats three aspects of such problems: modeling, analysis, and friction compensation. A new dynamic friction model is presented and investigated. The model is described by a first order nonlinear differential equation with a reasonable number of parameters, yet it captures most of the experimentally observed friction phenomena. The model is suitable both for simulation purposes and control design. Analysis of...

  17. Computerized treatment planning systems for external photon beam radiotherapy

    International Nuclear Information System (INIS)

    Computerized treatment planning systems (TPSs) are used in external beam radiotherapy to generate beam shapes and dose distributions with the intent to maximize tumour control and minimize normal tissue complications. Patient anatomy and tumour targets can be represented as 3-D models. The entire process of treatment planning involves many steps and the medical physicist is responsible for the overall integrity of the computerized TPS to accurately and reliably produce dose distributions and associated calculations for external beam radiotherapy. The planning itself is most commonly carried out by a dosimetrist, and the plan must be approved by a radiation oncologist before implementation in actual patient treatments. Treatment planning prior to the 1970s was generally carried out through the manual manipulation of standard isodose charts on to patient body contours that were generated by direct tracing or lead wire representation, and relied heavily on the judicious choice of beam weight and wedging by an experienced dosimetrist. The simultaneous development of computed tomography (CT), along with the advent of readily accessible computing power from the 1970s on, led to the development of CT based computerized treatment planning, providing the ability to view dose distributions directly superimposed upon a patient's axial anatomy. The entire treatment planning process involves many steps, beginning from beam data acquisition and entry into the computerized TPS, through patient data acquisition, to treatment plan generation and the final transfer of data to the treatment machine. Successive improvements in treatment planning hardware and software have been most notable in the graphics, calculation and optimization aspects of current systems. Systems encompassing the 'Virtual Patient' are able to display beam's eye views (BEVs) of radiation beams and digitally reconstructed radiographs (DRRs) for arbitrary dose distributions. Dose calculations have evolved from

  18. Chattering-free fuzzy adaptive robust sliding-mode vibration control of a smart flexible beam

    International Nuclear Information System (INIS)

    Chattering is an undesired phenomenon associated with classical sliding-mode control. The discontinuous bang–bang robust controller causes chattering near the equilibrium. To attenuate the chattering, in this paper, a fuzzy logic smooth switch system is integrated with the adaptive robust sliding-mode control to form a fuzzy adaptive robust sliding-mode control for the active vibration control of a smart flexible beam integrated with piezoceramic actuators and sensors. The asymptotical stability proof of the proposed fuzzy adaptive robust sliding-mode controller is provided by Lyapunov's direct method. The experimental results show that the proposed fuzzy adaptive robust sliding-mode controller quickly suppresses the vibration. Additionally, with the fuzzy switch system, the chattering is successfully attenuated

  19. Development of compact quantum beam generation system and the application

    International Nuclear Information System (INIS)

    After the approval of the project as the 'High-Tech Research Center Project' conducted by MEXT at Waseda University, the laser driven photo-cathode RF-Gun (RF-Gun) has been developed very extensively. The system was developed to obtain the stable and high quality (i.e. very low emittance) electron beam in conjunction with the system stabilization such as RF power source and laser system for the electron emission. The high quality electron beams have been applied for the development of novel beam diagnostic system. At the same time, the beams (electron and laser) are applied for the inverse Compton scattering experiment for the generation of soft-X-ray with quasi-monochromatic energy and short time structure, and for the pump probe experiment (the pico-second pulse radiolysis) as the very compact system. (author)

  20. Robust Laser Beam Tracking Control using Micro/Nano Dual-Stage Manipulators

    OpenAIRE

    Amari, Nabil; Folio, David; Ferreira, Antoine

    2013-01-01

    International audience This paper presents a study of the control problem of a laser beam illuminating and focusing a microobject subjected to dynamic disturbances using light intensity for feedback only. The main idea is to guide and track the beam with a hybrid micro/nanomanipulator which is driven by a control signal generated by processing the beam intensity sensed by a four-quadrant photodiode. Since the pointing location of the beam depends on real-time control issues related to temp...

  1. Stability Analysis of Nonlinear Feedback Control Methods for Beam Halo-chaos

    Institute of Scientific and Technical Information of China (English)

    WANGZhong-sheng; FANGJin-qing; CHENGuan-rong

    2003-01-01

    Control of beam halo-chaos has been a more challenge subject in recent years, in which nonlinear feedback method for beam halo-chaos has been developed for control of beam halo-chaos in high-current proton linear accelerators. However, stability analysis of nonlinear feedback control methods for beam halo-chaos has still been an open and important topic in this field. In this letter.

  2. Scanning system for charged and neutral particle beams

    International Nuclear Information System (INIS)

    The present invention aims at providing a simple and reliable method and a reliable device for irradiating a confined volume of matter, preferably at great depth, with a beam of high energy charged or neutral particles. The basic feature of the invention is that the particle beam coming from a radiation source of charged particles is scanned electrically in two orthogonal directions, and that the beam scanned in one plane is deflected in space. For most practical purposes it is important that the radiation source is of small extension. Such a radiation source is realized by means of a beam optical system that includes two scanning magnets each of which admits scanning of the particle beam in one of two orthogonal planes. The beam scanned in one of the planes leaves the associated scanning magnet from an effective scanning centre. The optical system also includes a deflection magnet disposed between the scanning magnets for deflecting the path of the beam in space. By utilizing the optical properties of the deflection magnet in such a way that the deflection magnet produces an image of the effective scanning centre of the first scanning magnet which coincides with the effective scanning centre of the second scanning magnet, the beam scanned in two orthogonal planes will radiate isotropically from the scanning centre of the second scanning magnet. By using the deflection magnet a compact scanning system with a small distance between the scanning centres of the scanning magnets is obtained

  3. Multi-electron beam system for high resolution electron beam induced deposition

    OpenAIRE

    Van Bruggen, M.J.

    2008-01-01

    The development of a multi-electron beam system is described which is dedicated for electron beam induced deposition (EBID) with sub-10 nm resolution. EBID is a promising mask-less nanolithography technique which has the potential to become a viable technique for the fabrication of 20-2 nm structures after 2013, as described by the International Technology Roadmap for Semiconductors (ITRS), or can be used for rapid prototyping in research applications. The key point is to combine the throughp...

  4. Antenna systems with beam forming and beam steering capabilities for HF skywave radars

    OpenAIRE

    Uluışık, Çağatay

    2010-01-01

    Radiation characteristics of linearly phased, periodic, planar dipole arrays, which can be used as transmitting/ receiving antenna systems for HF skywave radars, are investigated. Rectangular, triangular and trapezoidal arrays are proposed in obtaining different beam shapes in the desired directions. Beam steering is achieved by adjusting the inter-element phase increments coherently. The effects of vertical array-tilt with a desired take-off angle (TOA) α are presented by a number of radiati...

  5. Antenna systems with beam forming and beam steering capabilities for HF skywave radars

    OpenAIRE

    ULUIŞIK, Çağatay

    2010-01-01

    Radiation characteristics of linearly phased, periodic, planar dipole arrays, which can be used as transmitting/receiving antenna systems for HF skywave radars, are investigated. Rectangular, triangular and trapezoidal arrays are proposed in obtaining different beam shapes in the desired directions. Beam steering is achieved by adjusting the inter-element phase increments coherently. The effects of vertical array-tilt with a desired take-off angle (TOA) a are presented by a number o...

  6. neural control system

    International Nuclear Information System (INIS)

    Automatic power stabilization control is the desired objective for any reactor operation , especially, nuclear power plants. A major problem in this area is inevitable gap between a real plant ant the theory of conventional analysis and the synthesis of linear time invariant systems. in particular, the trajectory tracking control of a nonlinear plant is a class of problems in which the classical linear transfer function methods break down because no transfer function can represent the system over the entire operating region . there is a considerable amount of research on the model-inverse approach using feedback linearization technique. however, this method requires a prices plant model to implement the exact linearizing feedback, for nuclear reactor systems, this approach is not an easy task because of the uncertainty in the plant parameters and un-measurable state variables . therefore, artificial neural network (ANN) is used either in self-tuning control or in improving the conventional rule-based exper system.the main objective of this thesis is to suggest an ANN, based self-learning controller structure . this method is capable of on-line reinforcement learning and control for a nuclear reactor with a totally unknown dynamics model. previously, researches are based on back- propagation algorithm . back -propagation (BP), fast back -propagation (FBP), and levenberg-marquardt (LM), algorithms are discussed and compared for reinforcement learning. it is found that, LM algorithm is quite superior

  7. A device for a proton beam energy control for radiotherapy

    International Nuclear Information System (INIS)

    A Medical-Technical Facility for hadron radiotherapy based on the JINR DLNP phasotron has been constructed and put into operation. Upgrading of methods, hardware and software for radiotherapy is one of the main tasks for further development of the Facility. This article concerns one of the fields of this work, that is the development of equipment for dynamic irradiation of a deep lying target - the construction of a device for the proton beam energy control and measurement of its depth-dose curve in a treatment room. (author)

  8. Model of rotary-actuated flexible beam with notch filter vibration suppression controller and torque feedforward load compensation controller

    International Nuclear Information System (INIS)

    This paper describes ORNL's development of an environment for the simulation of robotic manipulators. Simulation includes the modeling of kinematics, dynamics, sensors, actuators, control systems, operators, and environments. Models will be used for manipulator design, proposal evaluation, control system design and analysis, graphical preview of proposed motions, safety system development, and training. Of particular interest is the development of models for robotic manipulators having at least one flexible link. As a first application, models have been developed for the Pacific Northwest Laboratory's Flexible Beam Test Bed (PNL FBTB), which is a 1-Degree-of-Freedom, flexible arm with a hydraulic base actuator. ORNL transferred control algorithms developed for the PNL FBTB to controlling IGRIP models. A robust notch filter is running in IGRIP controlling a full dynamics model of the PNL test bed. Model results provide a reasonable match to the experimental results (quantitative results are being determined) and can run on ORNL's Onyx machine in approximately realtime. The flexible beam is modeled as six rigid sections with torsional springs between each segment. The spring constants were adjusted to match the physical response of the flexible beam model to the experimental results. The controller is able to improve performance on the model similar to the improvement seen on the experimental system. Some differences are apparent, most notably because the IGRIP model presently uses a different trajectory planner than the one used by ORNL on the PNL test bed. In the future, the trajectory planner will be modified so that the experiments and models are the same. The successful completion of this work provides the ability to link C code with IGRIP, thus allowing controllers to be developed, tested, and tuned in simulation and then ported directly to hardware systems using the C language

  9. Control of spiking in partial penetration of electron beam welds. Final report, 1 October 1969--1 October 1976

    International Nuclear Information System (INIS)

    An investigation of the penetration mechanism of high energy density electron beams and an evaluation of electron beam deflection as a method of penetration control are presented. A discussion of electron beam mechanics including several penetration theories is presented in the introduction and background. Slur radiographs made using a pinhole x-ray camera are evaluated to determine velocity and acceleration of the point of beam impingement. Methods of cavity closure are discussed with possible causes of surface sealing of the beam cavity. A method of penetration, after the cavity has closed, based on the curves relating velocity and acceleration to penetration distance is considered. An estimate of cavity pressure is made from the maximum acceleration of the beam-metal interface. A system using an x-ray detector coupled with a beam deflecting device is detailed and evaluated. As this is the first attempt at penetration control by beam deflection the investigation seeks only to determine the feasibility of the idea without attempting a thorough analysis of range of abilities or quality of welds made by such devices. Based on several specimens which are presented beam deflection appears capable of controlling penetration depth. It is hoped that the ideas presented here will inspire future research along these lines

  10. The Ganil computer control system renewal

    International Nuclear Information System (INIS)

    Since 1982 the GANIL heavy ion accelerator has been under the control of 16-bit minicomputers MITRA, programmable logic controllers and microprocessorized Camac controllers, structured into a partially centralized system. This control system has to be renewed to meet the increasing demands of the accelerator operation which aims to provide higher quality ion beams under more reliable conditions. This paper gives a brief description of the existing control system and then discusses the main issues of the design and the implementation of the future control system: distributed powerful processors federated through Ethernet and flexible network-wide database access, VME standard and front-end microprocessors, enhanced color graphic tools and workstation based operator interface

  11. Real time management of the AD Schottky/BTF beam measurement system

    CERN Document Server

    Ludwig, M

    2003-01-01

    The AD Schottky and BTF system relies on rapid acquisition and analysis of beam quantisation noise during the AD cycle which is based on an embedded receiver and digital signal processing board hosted in a VME system. The software running in the VME sets up the embedded system and amplifiers, interfaces to the RF and control system, manages the execution speed and sequence constraints with respect to the various operating modes, schedules measurements during the AD cycle and performs post processing taking into account the beam conditions in an autonomous way. The operating modes of the instrument dynamically depend on a detailed configuration, the beam parameters during the AD cycle and optional user interaction. Various subsets of the processed data are available on line and in quasi real time for beam intensity, momentum spread and several spectrum types, which form an important part of AD operation today.

  12. Development of a raster electronics system for expanding the APT proton beam

    Energy Technology Data Exchange (ETDEWEB)

    Chapelle, S.; Hubbard, E.L.; Smith, T.L. [General Atomics, San Diego, CA (United States); Schulze, M.E.; Shafer, R.E. [General Atomics, Los Alamos, NM (United States)

    1998-12-31

    A 1700 MeV, 100 mA proton linear accelerator is being designed for Accelerator Production of Tritium (APT). A beam expansion system is required to uniformly irradiate a 19 x 190 cm tritium production target. This paper describes a beam expansion system consisting of eight ferrite dipole magnets to raster the beam in the x- and y-planes and also describes the salient features of the design of the electronics that are unique to the expander. Eight Insulated Gate Bipolar Transistor (IGBT)-based modulators drive the raster magnets with triangular current waveforms that are synchronized using phase-locked loops (PLLs) and voltage controlled crystal oscillators (VCXOs). Fault detection circuitry shuts down the beam before the target can be damaged by a failure of the raster system. Test data are presented for the prototype system.

  13. The control and diagnostics system for the CEBAF injector

    International Nuclear Information System (INIS)

    The authors present the first experience with the CEBAF injector control and diagnostics system. The computer architecture of the control system has been described elsewhere. The injector system is a model for the CEBAF controls. A computer system controls the gun, the steering magnets, and the focusing elements, and in the near future also the injector rf system. The beam parameters such as current, position, and emittance are measured by various monitors and are automatically analyzed by the computer. 5 refs., 11 figs

  14. Data Acquisition and Uesr Interface of Beam Instrumentation System at SRRC

    OpenAIRE

    Chen, Jenny; Wang, C J; Kuo, C. H.; Hu, K. H.; Chen, C S; Hsu, K. T.

    2001-01-01

    Data acquisition systems for the accelerator complex at SRRC composed various hardware and software components. Beam signals are processed by related processing electronics, and connect to control system by various type of interfaces in data acquisition front-end. These front-end include VME crates, personal computers and instruments bus adapters. Fast Ethernet connected all elements together with control consoles. User interface is running on control console. Real-time data capture; display ...

  15. Therminoic gun control system for the CEBAF injector

    International Nuclear Information System (INIS)

    The injector for the CEBAF accelerator must produce a high-quality electron beam to meet the overall accelerator specifications. A Hermosa electron gun with a 2 mm-diameter cathode and a control aperture has been chosen as the electron source. This must be controlled over a wide range of operating conditions to meet the beam specifications and to provide flexibility for accelerator commissioning. The gun is controlled using Computer Automated Measurement and Control (CAMAC IEEE-583) technology. The system employs the CAMAC-based control architecture developed at CEBAF. The control system has been tested, and early operating data on the electron gun and the injector beam transport system has been obtained. This system also allows gun parameters to be stored at the operator location, without paralyzing operation. This paper describes the use of this computer system in the control of the CEBAF electron gun. 2 refs., 6 figs., 1 tab

  16. Electron beam charge measurement on PHIL photo-injector using a microcontroller based system

    International Nuclear Information System (INIS)

    PHIL [1] is an electron beam accelerator at LAL. It produces low energy (E < 5 MeV) and high current (maximum 2nC/bunch, 10 ps duration) electron bunch at a repetition frequency of 5Hz. The beam charge measurements are performed by two Faraday Cups (FC) at both ends of the beam line and also with two Integrating Current Transformer (ICT), installed immediately after the RF gun and at the end of the straight beam line (see figure 1). Extracted signals from the ICT and FC, are processed by electronic circuits, displayed on an oscilloscope, and used to calculate the beam charge manually using the oscilloscope features. This operation is not accurate, does't permit to follow and save the temporal evolution of the charge and cannot be integrated in the control command system. To overcome this problem, a new approach was adopted, based on two systems: - An electronic back-end to integrate the signal from coming the charge measurement systems (20ns large pulse), and outputs a large duration signal (around 400μs) whose amplitude is proportional to the beam charge. - A microcontroller is used to acquire the integrated signal with a repetition rate of 5Hz, make the analog-digital conversion, and calculate the mean beam charge. The output signal can be sent to the control command system for displaying and to automate other process, especially the measurements of the beam charge versus RF/Laser phase. This system offers good accuracy, with a resolution of around 1pC, and can be easily integrated in the control command system

  17. Control of complex systems

    CERN Document Server

    Albertos, Pedro; Blanke, Mogens; Isidori, Alberto; Schaufelberger, Walter; Sanz, Ricardo

    2001-01-01

    The world of artificial systems is reaching complexity levels that es­ cape human understanding. Surface traffic, electricity distribution, air­ planes, mobile communications, etc. , are examples that demonstrate that we are running into problems that are beyond classical scientific or engi­ neering knowledge. There is an ongoing world-wide effort to understand these systems and develop models that can capture its behavior. The reason for this work is clear, if our lack of understanding deepens, we will lose our capability to control these systems and make they behave as we want. Researchers from many different fields are trying to understand and develop theories for complex man-made systems. This book presents re­ search from the perspective of control and systems theory. The book has grown out of activities in the research program Control of Complex Systems (COSY). The program has been sponsored by the Eu­ ropean Science Foundation (ESF) which for 25 years has been one of the leading players in stimula...

  18. Internal beam abort system for the Tevatron upgrade

    International Nuclear Information System (INIS)

    In this paper, the authors examine the properties of an internal beam dump system for the Tevatron running in the p bar p collider mode. The authors assume that the beam energy can be as high as 1.8 TeV. The motivation behind this report comes from the fact that the present proton abort system is a single-turn fast-extraction system, which becomes progressively more difficult to perform as the beam energy is raised without lengthening the straight section. The authors examine three different designs. The first is a system comprised of two beam dumps at each end of the existing straight section, the second dump acting as an absorber for the secondary particles produced in the primary dump as well as functioning as the primary dump for the particles of the opposite sign

  19. The beam handling system of the Oslo Cyclotron

    International Nuclear Information System (INIS)

    The beam optic system of the Oslo Cyclotron is described. A computer program for the calculation of optimal settings of quadropoles is presented. The reliability of the computer program is confirmed by experimental data

  20. Statistical control of the spectral quality index in electron beams

    International Nuclear Information System (INIS)

    Background and purpose: In radiotherapy with electron linear accelerators, it is mandatory to guarantee the stability of beam output spectra. In this work we study the quality control of the magnitude that provides the beam spectral quality, by following statistical techniques usual in industry process. Methods: We establish the differences between the measurement of the reference quality index, R50,ion, which involves usually a costly procedure, and that of the index used for the statistical control, which can be done in an easier way and with a higher frequency. The methodology developed is applied to a Siemens Mevatron KDS electron linear accelerator, specifically for the 6, 12 and 18 MeV modes. The uncertainties of both procedures are evaluated and are correlated. A retrospective analysis of the data registered during more than 13 years is carried out using CUSUM algorithmic and moving range charts. Results: The larger uncertainties in R50,ion come from the measurement device and the observer. The uncertainty in the measurement of the statistical control variable, which is mainly due to the geometry setup, is negligible against its intrinsic variability. The application of CUSUM charts pointed out different out of control situations linked in much cases to assignable causes. In addition, moving range charts showed up situations of anomalous functioning of the LINAC. Conclusions: Algorithmic CUSUM charts permit a nice monitoring of R50,ion. If the variability is not controlled, by using charts such as the moving range ones, the number of false alarms could increase without a change in the mean value of R50,ion.

  1. Optical manipulation with two beam traps in microfluidic polymer systems

    DEFF Research Database (Denmark)

    Khoury Arvelo, Maria; Matteucci, Marco; Sørensen, Kristian Tølbøl; Bilenberg, Brian; Vannahme, Christoph; Kristensen, Anders; Berg-Sørensen, Kirstine

    2015-01-01

    An optical trapping system with two opposing laser beams, also known as the optical stretcher, are naturally constructed inside a microfluidic lab-on-chip system. We present and compare two approaches to combine a simple microfluidic system with either waveguides directly written in the microflui......An optical trapping system with two opposing laser beams, also known as the optical stretcher, are naturally constructed inside a microfluidic lab-on-chip system. We present and compare two approaches to combine a simple microfluidic system with either waveguides directly written in the...... microfluidic chip or with optical fibers mounted in the chip....

  2. Design and performance of a video-based laser beam automatic alignment system

    Institute of Scientific and Technical Information of China (English)

    Daizhong Liu(刘代中); Renfang Xu(徐仁芳); Dianyuan Fan(范滇元)

    2004-01-01

    @@ A laser alignment system is applied to a high power laser facility for inertial confinement fusion.A designof the automated,close-loop laser beam alignment system is described.Its function is to sense beamalignment errors in a laser beam transport system and automatically steer mirrors preceding the sensorlocation as required to maintain beam alignment.The laser beam is sampled by a sensor package,whichuses video cameras to sense pointing and centering errors.The camera outputs are fed to a personalcomputer,which includes video digitizers and uses image storage and software to sense the centroid of theimage.Signals are sent through the computer to a stepper motor controller,which drives stepper motorson mirror mounts preceding the beam sampling location to return the beam alignment to the prescribedcondition.Its optical principles and key techniques are given.The pointing and centering sensitivities ofthe beam aligmnent sensor package are analyzed.The system has been verified on the multi-pass amplifier experimental system.

  3. Evolution and Control of 2219 Aluminum Microstructural Features through Electron Beam Freeform Fabrication

    Science.gov (United States)

    Taminger, Karen M.; Hafley, Robert A.; Domack, Marcia S.

    2006-01-01

    Electron beam freeform fabrication (EBF3) is a new layer-additive process that has been developed for near-net shape fabrication of complex structures. EBF3 uses an electron beam to create a molten pool on the surface of a substrate. Wire is fed into the molten pool and the part translated with respect to the beam to build up a 3-dimensional structure one layer at a time. Unlike many other freeform fabrication processes, the energy coupling of the electron beam is extremely well suited to processing of aluminum alloys. The layer-additive nature of the EBF3 process results in a tortuous thermal path producing complex microstructures including: small homogeneous equiaxed grains; dendritic growth contained within larger grains; and/or pervasive dendritic formation in the interpass regions of the deposits. Several process control variables contribute to the formation of these different microstructures, including translation speed, wire feed rate, beam current and accelerating voltage. In electron beam processing, higher accelerating voltages embed the energy deeper below the surface of the substrate. Two EBF3 systems have been established at NASA Langley, one with a low-voltage (10-30kV) and the other a high-voltage (30-60 kV) electron beam gun. Aluminum alloy 2219 was processed over a range of different variables to explore the design space and correlate the resultant microstructures with the processing parameters. This report is specifically exploring the impact of accelerating voltage. Of particular interest is correlating energy to the resultant material characteristics to determine the potential of achieving microstructural control through precise management of the heat flux and cooling rates during deposition.

  4. Electric turbocompound control system

    Science.gov (United States)

    Algrain, Marcelo C.

    2007-02-13

    Turbocompound systems can be used to affect engine operation using the energy in exhaust gas that is driving the available turbocharger. A first electrical device acts as a generator in response to turbocharger rotation. A second electrical device acts as a motor to put mechanical power into the engine, typically at the crankshaft. Apparatus, systems, steps, and methods are described to control the generator and motor operations to control the amount of power being recovered. This can control engine operation closer to desirable parameters for given engine-related operating conditions compared to actual. The electrical devices can also operate in "reverse," going between motor and generator functions. This permits the electrical device associated with the crankshaft to drive the electrical device associated with the turbocharger as a motor, overcoming deficient engine operating conditions such as associated with turbocharger lag.

  5. An advanced beam steering system for the SRS at Daresbury

    International Nuclear Information System (INIS)

    The Daresbury SRS is a 2 GeV electron storage ring dedicated to providing synchrotron radiation to approximately 32 stations on 10 beamlines. The storage ring beam steering systems are being replaced to allow automatic real time correction of the electron beam position. The stability problem and the proposed solutions are briefly summarized. Progress on development of the constituent systems is reviewed and some data from early performance trials is presented. (author) 7 refs.; 7 figs

  6. A beam guide system for laser-surgery

    International Nuclear Information System (INIS)

    A beam guide system for medical application is described. Using rotatable dielectric mirrors the transmission of the system is very high and the beam quality is not debased. A special end tube suitable for surgery in the nasal cavity is presented solving the problems of a clean optical end face. The instrument was applied clinically to surgery of the lower human turbinates using an argon ion laser with a power up to 4 W. (Author)

  7. Transient Beam Loading in the ALS Harmonic RF System

    International Nuclear Information System (INIS)

    We report on the commissioning of a higher harmonic radiofrequency system at the Advanced Light Source, designed to improve the beam lifetime. We have achieved an increase above a factor of two in our best results up to now. Transient beam loading of the harmonic cavities, due to the unequal fill patterns, creates the greatest limitations on lifetime improvement. We also describe several interesting effects on the operation of the longitudinal and transverse multibunch feedback systems

  8. Alignment of the SLC Final Focus system using beam orbits

    International Nuclear Information System (INIS)

    Beam based alignment is being routinely applied in the SLC Final Focus and has proved to be a very useful tool for determining the quality of the zeroth order orbit as defined by various beam line elements. Given the stringent requirement on the beam quality at the interaction point, a well aligned beam line is essential in that it minimizes the confusion which would otherwise arise in the higher order optics, the demand called on the correctors which also serve as optical knobs, and the problem associated with the background radiation. In the SLC final focus we have been relying on an interplay between the field survey and the orbit analysis to achieve this purpose. Mechanical alignment generally provides coordinate information of various beam line elements and offset values inferred from these data and the model of the beam line. Beam based alignment is done mainly by recording the beam orbit under controlled experiment where optical elements or orbit conditions are varied. Due to the complexity of the beamline layout and special power supply configuration in the SLC Final Focus, the latter method is useful only when coupled with off-line analysis which disentangles the data taken at each measurement. In this report we describe the techniques used and the underlying principle, the procedure as applied in the Final Focus, the outcome of this exercise and some problems encountered. 6 figs

  9. BECOLA Beam Line Construction and Laser System

    Science.gov (United States)

    Pedicini, Eowyn; Minamisono, Kei; Barquest, Brad; Bollen, Georg; Klose, Andrew; Mantica, Paul; Morrissey, Dave; Ringle, Ryan; Schwarz, Stefan; Vinnikova, Sophia

    2010-11-01

    The BECOLA (BEam COoler and LAser spectroscopy) facility is being installed at NSCL for experiments on radioactive nuclides.ootnotetextK. Minamisono et al, Proc. Inst. Nucl. Theory 16, 180 (2009). Low energy ion beams will be cooled/bunched in an RFQ ion trap and then extracted to a max of 60 kV. The ion beam will be neutralized through a charge exchange cell (CEC), and remaining ions will be removed by a deflector and collected in a Faraday cup. Collinear laser spectroscopy will be used to measure the atomic hyperfine structure, and nuclear properties will be extracted. The assembly, vacuum testing, and optical alignment of the CEC have been completed and the ion deflector and Faraday cup were also assembled. Stabilization of the Ti:sapphire laser to be used for spectroscopy is achieved through a feedback loop using a precision wavelength meter that is calibrated by a stabilized He-Ne laser. Coupling the He-Ne laser into a single-mode optical fiber was optimized for stable operation of the feedback loop. Finally, a wall chart of nuclear moments was prepared to view trends in μ and Q for nuclear ground states for planning future measurements.

  10. Image processing system for electron linac beam diagnosis

    International Nuclear Information System (INIS)

    For diagnosis of electron linac beams, image signals from a TV camera viewing a ceramic screen monitor were processed and analyzed using a waveform digitizer and a personal computer. The black-and-white TV camera used has a zoom lens with a remote-controllable iris; the automatic gain control circuit was switched off to obtain tolerable linearity of the output video signal against the brightness of the beam spot on the screen. The video signals are taken by the waveform digitizer with a sampling rate of 4 MHz; the digitized picture is transmitted to the personal computer via the GPIB and is analyzed to derive spatial intensity distribution of the beam. The sync signal of the TV camera is externally synchronized with the electron linac beam timing

  11. Control of beam halo-chaos by delayed self-controlling feedback

    CERN Document Server

    Zhu Lun Wu; Gao Yuan; Fang Jin Qing

    2002-01-01

    The delayed self-controlling feedback method is used to control beam halo-chaos in high-intensity accelerator effectively under five different initial distributions of protons. A brief theoretic analysis is presented. This method, considering its linear controller and weak feedback, has the advantage in technology realizability and cost saving. It cna be a good reference in the application to high-intensity accelerators

  12. A beam-synchronous gated peak-detector for the LHC beam observation system

    CERN Document Server

    Levens, T E; Wehrle, U

    2013-01-01

    Measurements of the bunch peak amplitude using the longitudinal wideband wall-current monitor are a vital tool used in the Large Hadron Collider (LHC) beam observation system. These peak-detected measurements can be used to diagnose bunch shape oscillations, for example coherent quadrupole oscillations, that occur at injection and during beam manipulations. Peak-detected Schottky diagnostics can also be used to obtain the synchrotron frequency distribution and other parameters from a bunched beam under stable conditions. For the LHC a beam-synchronous gated peak detector has been developed to allow individual bunches to be monitored without the influence of other bunches circulating in the machine. The requirement for the observation of both low intensity pilot bunches and high intensity bunches for physics requires a detector front-end with a high bandwidth and a large dynamic range while the usage for Schottky measurements requires low noise electronics. This paper will present the design of this detector s...

  13. Telerobot control system

    Science.gov (United States)

    Backes, Paul G.; Tso, Kam S.

    1993-07-01

    This invention relates to an operator interface for controlling a telerobot to perform tasks in a poorly modeled environment and/or within unplanned scenarios. The telerobot control system includes a remote robot manipulator linked to an operator interface. The operator interface includes a setup terminal, simulation terminal, and execution terminal for the control of the graphics simulator and local robot actuator as well as the remote robot actuator. These terminals may be combined in a single terminal. Complex tasks are developed from sequential combinations of parameterized task primitives and recorded teleoperations, and are tested by execution on a graphics simulator and/or local robot actuator, together with adjustable time delays. The novel features of this invention include the shared and supervisory control of the remote robot manipulator via operator interface by pretested complex tasks sequences based on sequences of parameterized task primitives combined with further teleoperation and run-time binding of parameters based on task context.

  14. UV laser beam switching system for Yb trapped ion quantum information processing

    Science.gov (United States)

    Scherer, David R.; Hensley, Joel M.; Parameswaran, Krishnan R.; Bamford, Douglas J.; Mount, Emily; Crain, Stephen; Kim, Jungsang

    2012-02-01

    Qubits based on trapped ions are being investigated as a promising platform for scalable quantum information processing. One challenge associated with the scalability of such a multi-qubit trapped ion system is the need for an ultraviolet (UV) laser beam switching and control system to independently modulate and address large qubit arrays. In this work, we propose and experimentally demonstrate a novel architecture for a laser beam control system for trapped ion quantum computing based on fast electro-optic amplitude switching and high-fidelity electromechanical beam shuttering using a microelectromechanical systems (MEMS) deflector coupled into a single-mode optical fiber. We achieve a rise/fall time of 5 ns, power extinction of -31 dB, and pulse width repeatability of > 99.95% using an electrooptic switch based on a β-BaB2O4 (BBO) Pockels cell. A tilting MEMS mirror fabricated using a commercial foundry was used to steer UV light into a single-mode optical fiber, resulting in an electromechanical beam shutter that demonstrated a power extinction of -52 dB and a switching time of 2 μs. The combination of these two technologies allows for high-fidelity power extinction using a platform that does not suffer from temperature-induced beam steering due to changes in modulation duty cycle. The overall system is capable of UV laser beam switching to create the resolved sideband Raman cooling pulses, algorithm pulses, and read-out pulses required for quantum computing applications.

  15. Exponential stabilization of a Rayleigh beam using collocated control

    NARCIS (Netherlands)

    Weiss, George; Curtain, Ruth F.

    2008-01-01

    We consider a hinged elastic beam described by the Rayleigh beam equation on the interval [0, pi]. We assume the presence of two sensors: one measures the angular velocity of the beam at a point xi is an element of [0, pi] and the other measures the bending (curvature) of the beam at the same point.

  16. An Energy Saving System for a Beam Pumping Unit.

    Science.gov (United States)

    Lv, Hongqiang; Liu, Jun; Han, Jiuqiang; Jiang, An

    2016-01-01

    Beam pumping units are widely used in the oil production industry, but the energy efficiency of this artificial lift machinery is generally low, especially for the low-production well and high-production well in the later stage. There are a number of ways for energy savings in pumping units, with the periodic adjustment of stroke speed and rectification of balance deviation being two important methods. In the paper, an energy saving system for a beam pumping unit (ESS-BPU) based on the Internet of Things (IoT) was proposed. A total of four types of sensors, including load sensor, angle sensor, voltage sensor, and current sensor, were used to detect the operating conditions of the pumping unit. Data from these sensors was fed into a controller installed in an oilfield to adjust the stroke speed automatically and estimate the degree of balance in real-time. Additionally, remote supervision could be fulfilled using a browser on a computer or smartphone. Furthermore, the data from a practical application was recorded and analyzed, and it can be seen that ESS-BPU is helpful in reducing energy loss caused by unnecessarily high stroke speed and a poor degree of balance. PMID:27187402

  17. An Energy Saving System for a Beam Pumping Unit

    Science.gov (United States)

    Lv, Hongqiang; Liu, Jun; Han, Jiuqiang; Jiang, An

    2016-01-01

    Beam pumping units are widely used in the oil production industry, but the energy efficiency of this artificial lift machinery is generally low, especially for the low-production well and high-production well in the later stage. There are a number of ways for energy savings in pumping units, with the periodic adjustment of stroke speed and rectification of balance deviation being two important methods. In the paper, an energy saving system for a beam pumping unit (ESS-BPU) based on the Internet of Things (IoT) was proposed. A total of four types of sensors, including load sensor, angle sensor, voltage sensor, and current sensor, were used to detect the operating conditions of the pumping unit. Data from these sensors was fed into a controller installed in an oilfield to adjust the stroke speed automatically and estimate the degree of balance in real-time. Additionally, remote supervision could be fulfilled using a browser on a computer or smartphone. Furthermore, the data from a practical application was recorded and analyzed, and it can be seen that ESS-BPU is helpful in reducing energy loss caused by unnecessarily high stroke speed and a poor degree of balance. PMID:27187402

  18. Software architecture considerations for ion source control systems

    International Nuclear Information System (INIS)

    General characteristics of distributed control system software tools are examined from the perspective of ion source control system requirements. Emphasis is placed on strategies for building extensible, distributed systems in which the ion source element is one component of a larger system. Vsystem, a commercial software tool kit from Vista Control Systems was utilized extensively in the control system upgrade of the Holifield Radioactive Ion Beam Facility. Part of the control system is described and the characteristics of Vsystem are examined and compared with those of EPICS, the Experimental Physics and Industrial Control System

  19. System for beaming power from earth to a high altitude platform

    Science.gov (United States)

    Friedman, Herbert W.; Porter, Terry J.

    2002-01-01

    Power is transmitted to a high altitude platform by an array of diode pumped solid state lasers each operated at a single range of laser wavelengths outside of infrared and without using adaptive optics. Each laser produces a beam with a desired arrival spot size. An aircraft avoidance system uses a radar system for automatic control of the shutters of the lasers.

  20. Laser beam riding guided system principle and design research

    Science.gov (United States)

    Qu, Zhou; Jin, Yi; Xu, Zhou; Xing, Hao

    2016-01-01

    With the development of science and technology, precision-strike weapons has been considered to be important for winning victory in military field. Laser guidance is a major method to execute precision-strike in modern warfare. At present, the problems of primary stage of Laser guidance has been solved with endeavors of countries. Several technical aspects of laser-beam riding guided system have been mature, such as atmosphere penetration of laser beam, clutter inhibition on ground, laser irradiator, encoding and decoding of laser beam. Further, laser beam quality, equal output power and atmospheric transmission properties are qualified for warfare situation. Riding guidance instrument is a crucial element of Laser-beam riding guided system, and is also a vital element of airborne, vehicle-mounted and individual weapon. The optical system mainly consist of sighting module and laser-beam guided module. Photoelectric detector is the most important sensing device of seeker, and also the key to acquire the coordinate information of target space. Currently, in consideration of the 1.06 u m of wavelength applied in all the semi-active laser guided weapons systems, lithium drifting silicon photodiode which is sensitive to 1.06 u m of wavelength is used in photoelectric detector. Compared to Solid and gas laser, diode laser has many merits such as small volume, simple construction, light weight, long life, low lost and easy modulation. This article introduced the composition and operating principle of Laser-beam riding guided system based on 980 nm diode laser, and made a analysis of key technology; for instance, laser irradiator, modulating disk of component, laser zooming system. Through the use of laser diode, Laser-beam riding guided system is likely to have smaller shape and very light.

  1. Advanced access control system

    International Nuclear Information System (INIS)

    A prototype voice verification system has been installed which provides the required positive identification at the main site access control point. This system compares an individual's file voice print with a sample voice print obtained from the individual when an attempt is made to enter the site. The voice system transmits the individual's identity to a central processor. The central processor associates that individual's authorization file with a card-key obtained at the access point. The system generates a record of personnel movement, provides a personnel inventory on a real-time basis, and it can retrieve a record of all prior events. The system installed at the Barnwell Nuclear Fuel Plant is described

  2. Beam Tracking in Switched-Beam Antenna System for V2V Communication

    Directory of Open Access Journals (Sweden)

    Settawit Poochaya

    2016-01-01

    Full Text Available This paper presents the proposed switched beam antenna system for V2V communication including optimum antenna half power beamwidth determination in urban road environments. SQP optimization method is selected for the computation of optimum antenna half power beamwidth. In addition, beam tracking algorithm is applied to guarantee the best beam selection with maximum RSSI. The results present the success of the proposed system with the increasing of V2V performance metrics. Also, V2V data dissemination via the proposed system introduces the enhancement of V2V link in terms of RSSI, PER, BER, Tsafe, and Rsafe. The results indicate the improvement of V2V link reliability. Consequently, the road safety is improved.

  3. Beam forming system modernization at the MMF linac proton injector

    CERN Document Server

    Derbilov, V I; Nikulin, E S; Frolov, O T

    2001-01-01

    The isolation improvements of the beam forming system (BFS) of the MMF linac proton injector ion source are reported. The mean beam current and,accordingly, BFS electrode heating were increased when the MMF linac has began to operate regularly in long beam sessions with 50 Hz pulse repetition rate. That is why the BFS electrode high-voltage isolation that was made previously as two consequently and rigidly glued solid cylinder insulators has lost mechanical and electric durability. The substitution of large (160 mm) diameter cylinder insulator for four small diameter (20 mm) tubular rods has improved vacuum conditions in the space of beam forming and has allowed to operate without failures when beam currents being up to 250 mA and extraction and focusing voltage being up to 25 and 40 kV respectively. Moreover,the construction provides the opportunity of electrode axial move. The insulators are free from electrode thermal expansion mechanical efforts in a transverse direction.

  4. Vibration Analysis and Control of Flexible Beam by Using Smart Damping Structures

    Science.gov (United States)

    Chen, Q.; Levy, C.

    1999-01-01

    The temperature effects on frequency, loss factor and control of a flexible beam with a constrained viscoelastic layer and shape memory alloy layer (SMA) are discussed. It is shown that the temperature in the SMA (actuation) layer is very important in the determination of frequency and loss factor of such a structure. The effects of damping layer shear modulus and damping layer height as affected by the temperature are also discussed. As temperature plays such an important role, it is, therefore, imperative to evaluate temperature effects on the control of the system as well. Results with and without active control are discussed.

  5. The next generation control system of GANIL

    International Nuclear Information System (INIS)

    The existing computer control system of GANIL is being renewed to fulfil the increasing requirements of the accelerator operation. This medium term major improvement is aiming at providing the physicists with a wider range of ion beams of higher quality under more flexible and reliable conditions. This paper gives a short description of the new control system envisioned. It consists of a three layer distributed architecture federating a VAX6000-410/VMS host computer, a real time control system made up of a dual host VAX3800 and workstation based operator consoles, and at the frontend segment: VME and CAMAC processors running under the VAXELN operating system, and programmable logic controllers for local controls. The basic issues with regard to architecture, human interface, information management, ... are discussed. Lastly, first implementations and operation results are presented. (author)

  6. The new accelerator control system of GANIL

    International Nuclear Information System (INIS)

    The new computer control system is conducting the heavy ion accelerator GANIL from the beginning of 1993 and has reached a state of routine operation. It was carried out to supersede the obsolete initial system and to cope with the harsh experimental conditions required by the very high intensity beams envisioned for the next future. Hardware and software implementations, as well as human interface, are presented. Emphasis is placed on the three-layer distributed architecture adopted. An ETHERNET local area network (LAN) links the basic components: a VAX/VMS cluster, XWINDOWS interfaced operator consoles, VAXELN driven CAMAC crate controllers and programmable logic controllers for front end controls. Also data management with the INGRES relational database management system (RDBMS), as well as operating software written in ADA language, are described. First experience with the new control system is reported. Finally, trend considerations are addressed. (author) 8 refs., 6 figs

  7. An Object-Oriented linac control system

    International Nuclear Information System (INIS)

    The ESRF linac has been working since the start of its commissioning (1991) with an industrial turnkey Control System which was not giving reliable service and was difficult to interface to the ESRF machine control system (MCS). It was decided in 1992 to redesign the entire linac electronic interface, using ESRF standards. Following this, it was decided to redesign the control system and to integrate it as part of the proven ESRF distributed control system [W.D. Klotz, Proc. Int. Conf. on Accelerator and Large Physics Experiments (ICALEPS-91), Tsukuba, Japan]. Preparation of the software began in spring 93. The installation and commissioning of the hardware and software has been carried out during a six week summer shutdown. The linac delivered its first beam on schedule using the complete control software. ((orig.))

  8. Ion beam induced fluorescence imaging in biological systems

    Science.gov (United States)

    Bettiol, Andrew A.; Mi, Zhaohong; Vanga, Sudheer Kumar; Chen, Ce-belle; Tao, Ye; Watt, Frank

    2015-04-01

    Imaging fluorescence generated by MeV ions in biological systems such as cells and tissue sections requires a high resolution beam (system and a fluorescent probe that has a high quantum efficiency and low bleaching rate. For cutting edge applications in bioimaging, the fluorescence imaging technique needs to break the optical diffraction limit allowing for sub-cellular structure to be visualized, leading to a better understanding of cellular function. In a nuclear microprobe this resolution requirement can be readily achieved utilizing low beam current techniques such as Scanning Transmission Ion Microscopy (STIM). In recent times, we have been able to extend this capability to fluorescence imaging through the development of a new high efficiency fluorescence detection system, and through the use of new novel fluorescent probes that are resistant to ion beam damage (bleaching). In this paper we demonstrate ion beam induced fluorescence imaging in several biological samples, highlighting the advantages and challenges associated with using this technique.

  9. Rf control system for a rocket-borne accelerator

    International Nuclear Information System (INIS)

    The Beam Experiments Aboard Rockets (BEAR) accelerator experiment imposes several nonstandard requirements on the rf control system. The experiment is entirely hands-off and must operate under local computer control. The rf control system must be extremely reliable, which implies excellence in design and fabrication as well as redundancy whenever possible. This paper describes the design of the frequency-source, frequency-control, and amplitude-control systems for the BEAR experiment

  10. High beam current shut-off systems in the APS linac and low energy transfer line

    International Nuclear Information System (INIS)

    Two independent high beam current shut-off current monitoring systems (BESOCM) have been installed in the APS linac and the low energy transport line to provide personnel safety protection in the event of acceleration of excessive beam currents. Beam current is monitored by a fast current transformer (FCT) and fully redundant supervisory circuits connected to the Access Control Interlock System (ACIS) for beam intensity related shutdowns of the linac. One FCT is located at the end of the positron linac and the other in the low energy transport line, which directs beam to the positron accumulator ring (PAR). To ensure a high degree of reliability, both systems employ a continuous self-checking function, which injects a test pulse to a single-turn test winding after each ''real'' beam pulse to verify that the system is fully functional. The system is designed to be fail-safe for all possible system faults, such as loss of power, open or shorted signal or test cables, loss of external trigger, malfunction of gated integrator, etc. The system has been successfully commissioned and is now a reliable part of the total ACIS

  11. Experiments on laser beam jitter control with applications to a shipboard free electron laser

    OpenAIRE

    Bateman, Brett E.

    2007-01-01

    A Free Electron Laser (FEL) shows potential as an effective defensive weapon for a naval ship against today's modern weapons such as supersonic anti-ship missiles. A laser can destroy these fast and highly maneuverable missiles at the speed of light. Several obstacles must be overcome to employ this weapon on a naval ship. This thesis discusses several methods for passive and active jitter control of a guided optical beam which might be employed in a FEL weapon system. Vibration experime...

  12. Development of the electron gun control system of SSRF

    International Nuclear Information System (INIS)

    An electron gun is the key part of a linac, the beam quality of which depends on beam quality of the electron gun, hence the need of a stable control system of the electron gun to ensure its safe operation.In this paper, we report our progresses in developing the linac's electron gun control system of Shanghai Synchrotron Radiation Facility (SSRF). It uses PLC as the device controllers, with the monitoring software developed on EPICS. The whole system is connected by Ethernet. The PLC and Ethernet technology ensures good reliability and easy maintenance of the electron gun control system. (authors)

  13. Diagnostic Lithium Beam System for COMPASS Tokamak

    Czech Academy of Sciences Publication Activity Database

    Háček, P.; Weinzettl, Vladimír; Stöckel, Jan; Anda, G.; Veres, G.; Zoletnik, S.; Berta, M.

    Prague : MATFYZPRESS, 2011 - (Šafránková, J.; Pavlů, J.), s. 215-220 ISBN 978-80-7378-185-9. - (WDS. 2). [WDS 2011 - Annual Conference of Doctoral Students /20./. Prague (CZ), 31.05.2011-03.06.2011] R&D Projects: GA ČR GA202/09/1467 Institutional research plan: CEZ:AV0Z20430508 Keywords : plasma diagnostics * tokamak, COMPASS * beam diagnostics Subject RIV: BL - Plasma and Gas Discharge Physics http:// server .ipp.cas.cz/~vwei/work/wds2010_201_f2.pdf

  14. Supervision Software for the Integration of the Beam Interlock System with the CERN Accelerator Complex

    CERN Document Server

    Audrain, M; Dragu, M; Fuchsberger, K; Garnier, JC; Gorzawski, AA; Koza, M; Krol, K; Moscatelli, A; Puccio, B; Stamos, K; Zerlauth, M

    2014-01-01

    The Accelerator complex at the European Organisation for Nuclear Research (CERN) is composed of many systems which are required to function in a valid state to ensure safe beam operation. One key component of machine protection, the Beam Interlock System (BIS), was designed to interface critical systems around the accelerator chain, provide fast and reliable transmission of beam dump requests and trigger beam extraction in case of malfunctioning of equipment systems or beam losses. Numerous upgrades of accelerator and controls components during the Long Shutdown 1 (LS1) are followed by subsequent software updates that need to be thoroughly validated before the restart of beam operation in 2015. In parallel, the ongoing deployments of the BIS hardware in the PS booster (PSB) and the future LINAC4 give rise to new requirements for the related controls and monitoring software due to their fast cycle times. This paper describes the current status and ongoing work as well as the long-term vision for the integratio...

  15. Embedded remote control of time-resolved OTR measurement system

    International Nuclear Information System (INIS)

    The on-line measurement system based on OTR can be used to measure the parameters of the intense electron beam, such as beam energy, divergence and emittance, and it has characteristics of ultra-fast response and high special resolution. With the embedded remote controll system, the time-resolved OTR measurement has been implemented successfully. The computer controll system receives the photoelectric video frequency signal, transmits real time image, and gets the dynamic image. This work removes the difficulties of strong disturbance in the beam measurement of intense LIA. (authors)

  16. Development of a magnetic beam guiding system for tumor-specific radiotherapy using heavy, charged particles

    International Nuclear Information System (INIS)

    An active, magnetic beam guiding system was developed and tested for the purpose of enhanced and tumor-specific irradiation of irregularly shaped target volumina. Combining intensity-controlled wobbling in rapidly changing magnetic fields with the heavy-ion synchrotron's capacity of fast energy variation achieved a new technique allowing good range modulation. This technique allows the calculated dose distribution to be exactly matched to target contours, and at the same time guarantees best possible quality of the radiation beam, since there is no need for use of mechanical beam shaping members. The components of the scanning system and a specifically designed instrumentation and control concept for this configuration were integrated into the synchrotron's control system, so that there is now a system available offering free selection of beam characteristics combined with energy variation along with the pulsed operation of the accelerator. The system was tested at the biophysical measuring unit of the GSI implementing an elaborated irradiation method at this unit equipped with tools for physico-technical irradiation planning and performance. Methods were designed and tested for optimizing the beam path within a given contour, the optimization taking into account the effects of transmission functions of the scanner components on the results of radiation treatments. (orig.)

  17. Preliminary results, obtained by using a proton beam, for an active scanning system to installed on the KHIMA

    Science.gov (United States)

    Kim, Chang Hyeuk; Lee, Hwa-Ryun; Jang, Sea Duk; Kim, Hyunyong; Hahn, Garam; Kim, Jeong Hwan; Jang, Hong Suk; Park, Dong Wook; Hwang, Won Taek; Yang, Tae-Keun

    2015-08-01

    The active scanning technique is a pencil beam delivery method in particle therapy. The active scanning beam delivery system consists of a beam scanner, beam monitor, energy modulator, and related programs, such as the irradiation control and planning programs. A proposed prototype active scanning system was designed and installed on MC-50 at the Korea Institute of Radiological and Medical Science (KIRAMS) with a 45-MeV proton beam. The laminated magnetic yoke of the scanning magnet supported fast ramping. The beam intensity and the beam profile monitors were designed for measuring the beam's properties. Both the range shifter and the ridge filter modulate the incoming beam energy. The LabVIEW®-based beam-irradiation-control program operates the system in a sequential operation manner for use with the MC-50 cyclotron. In addition, an in-housecoded irradiation-planning program generates an optimal irradiation path. A scanning experiment was successfully completed to print the logo of the Korea Heavy Ion Medical Accelerator (KHIMA) on GaF film. Moreover, the beam's position accuracy was measured as 0.62 mm in the x-direction and as 0.83 mm in the y-direction.

  18. Fault Tolerant Control Systems

    DEFF Research Database (Denmark)

    Bøgh, S.A.

    from this study highlights requirements for a dedicated software environment for fault tolerant control systems design. The second detailed study addressed the detection of a fault event and determination of the failed component. A variety of algorithms were compared, based on two fault scenarios in...... faults, but also that the research field still misses a systematic approach to handle realistic problems such as low sampling rate and nonlinear characteristics of the system. The thesis contributed with methods to detect both faults and specifically with a novel algorithm for the actuator fault...... detection that is superior in terms of performance and complexity to the other algorithms in the comparative study....

  19. JET neutral beam injection system, construction and component tests

    International Nuclear Information System (INIS)

    The two neutral injection systems for JET are each determined by 40 mw beam power extracted from eight sources during 10 s pulses. Under the existing spatial restrictions, this has led to a complex beam-line system design. The applied manufacturing techniques and the approach to quality assurance are discussed. The beam sources have been operated at 80 kv, 60 a, 5 s in hydrogen. Plasma source development has increased the H+ yield to approximately 84%. Beamlet steering by aperture offset has experimentally been adjusted to the values required for the restricted tokamak entrance geometry. A beam source has also been operated at 160 kv, 37 a in deuterium. At the tokamak the 7 m high injector vacuum box has been installed incorporating a fast shutter and a cryopump. This LHE cooled pump with 40 m2 entrance area and 45% pumping efficiency has successfully been tested as well as the flexible cryoliquid transfer-lines. The bakeable valve between injector box and tokamak vacuum (1.1 m x 0.5 m gate cross-section) has been operated with leak rates <10-9 mbar1/s. The sub-system commissioning is completed by short-pulse operation of the beam sources with their final power supplies in situ at the tokamak and, in parallel to this, testing of the beam-line system in the neutral injection testbed

  20. Incoherent control of locally controllable quantum systems

    International Nuclear Information System (INIS)

    An incoherent control scheme for state control of locally controllable quantum systems is proposed. This scheme includes three steps: (1) amplitude amplification of the initial state by a suitable unitary transformation, (2) projective measurement of the amplified state, and (3) final optimization by a unitary controlled transformation. The first step increases the amplitudes of some desired eigenstates and the corresponding probability of observing these eigenstates, the second step projects, with high probability, the amplified state into a desired eigenstate, and the last step steers this eigenstate into the target state. Within this scheme, two control algorithms are presented for two classes of quantum systems. As an example, the incoherent control scheme is applied to the control of a hydrogen atom by an external field. The results support the suggestion that projective measurements can serve as an effective control and local controllability information can be used to design control laws for quantum systems. Thus, this scheme establishes a subtle connection between control design and controllability analysis of quantum systems and provides an effective engineering approach in controlling quantum systems with partial controllability information.

  1. Wave Propagation in an Ion Beam-Plasma System

    DEFF Research Database (Denmark)

    Jensen, T. D.; Michelsen, Poul; Juul Rasmussen, Jens

    1979-01-01

    The spatial evolution of a velocity- or density-modulated ion beam is calculated for stable and unstable ion beam plasma systems, using the linearized Vlasov-Poisson equations. The propagation properties are found to be strongly dependent on the form of modulation. In the case of velocity...... modulation, the perturbation grows initially and then shows a periodic change of amplitude along the beam, while in the case of a density modulation only an instability causes growth. The findings are in agreement with experimental results obtained by SATO et al. (1977)....

  2. VME applications to the Daresbury SRS control system

    International Nuclear Information System (INIS)

    The control system for the Daresbury SRS has recently been extended with a VME based alarm system which is operational. A further development is a steering system to provide servo control of the electron beam orbit position in the storage ring. (author)

  3. Molecular beam sampling system with very high beam-to-background ratio: The rotating skimmer concept

    International Nuclear Information System (INIS)

    A novel method of reducing the background pressure in a vacuum system used for sampling a molecular beam from a high pressure region is presented. A triple differential pumping stage is constructed with a chopper with rotating skimmer within the first pumping stage, which serves effectively as a valve separating periodically the vacuum system from the ambient environment. The mass spectrometry measurement of the species in the molecular beam show an excellent beam-to-background ratio of 14 and a detection limit below 1 ppm. The potential of this method for detection of low density reactive species in atmospheric pressure plasmas is demonstrated for the detection of oxygen atoms generated in an atmospheric pressure microplasma source.

  4. Modular thyristor controlled series capacitor control system

    Energy Technology Data Exchange (ETDEWEB)

    Clark, K.; Larsen, E.V.; Wegner, C.A.; Piwko, R.J.

    1995-06-13

    A modular thyristor controlled series capacitor (TCSC) system, including a method and apparatus, uses phase controlled firing based on monitored capacitor voltage and line current. For vernier operation, the TCSC system predicts an upcoming firing angle for switching a thyristor controlled commutating circuit to bypass line current around a series capacitor. Each bypass current pulse changes the capacitor voltage proportionally to the integrated value of the current pulse. The TCSC system promptly responds to an offset command from a higher-level controller to control bypass thyristor duty to minimize thyristor damage, and to prevent capacitor voltage drift during line current disturbances. In a multi-module TCSC system, the higher level controller accommodates competing objectives of various system demands, including minimizing losses in scheduling control, stabilizing transients, damping subsynchronous resonance (SSR) oscillations, damping direct current (DC) offset, and damping power-swings. 67 figs.

  5. Characterizing and Controlling Beam Losses at the LANSCE Facility

    Energy Technology Data Exchange (ETDEWEB)

    Rybarcyk, Lawrence J. [Los Alamos National Laboratory

    2012-09-12

    The Los Alamos Neutron Science Center (LANSCE) currently provides 100-MeV H{sup +} and 800-MeV H{sup -} beams to several user facilities that have distinct beam requirements, e.g. intensity, micropulse pattern, duty factor, etc. Minimizing beam loss is critical to achieving good performance and reliable operation, but can be challenging in the context of simultaneous multi-beam delivery. This presentation will discuss various aspects related to the observation, characterization and minimization of beam loss associated with normal production beam operations in the linac.

  6. A large distributed digital camera system for accelerator beam diagnostics

    Science.gov (United States)

    Catani, L.; Cianchi, A.; Di Pirro, G.; Honkavaara, K.

    2005-07-01

    Optical diagnostics, providing images of accelerated particle beams using radiation emitted by particles impinging a radiator, typically a fluorescent screen, has been extensively used, especially on electron linacs, since the 1970's. Higher intensity beams available in the last decade allow extending the use of beam imaging techniques to perform precise measurements of important beam parameters such as emittance, energy, and energy spread using optical transition radiation (OTR). OTR-based diagnostics systems are extensively used on the superconducting TESLA Test Facility (TTF) linac driving the vacuum ultraviolet free electron laser (VUV-FEL) at the Deutsches Elektronen-Synchrotron facility. Up to 30 optical diagnostic stations have been installed at various positions along the 250-m-long linac, each equipped with a high-performance digital camera. This paper describes the new approach to the design of the hardware and software setups required by the complex topology of such a distributed camera system.

  7. A large distributed digital camera system for accelerator beam diagnostics

    International Nuclear Information System (INIS)

    Optical diagnostics, providing images of accelerated particle beams using radiation emitted by particles impinging a radiator, typically a fluorescent screen, has been extensively used, especially on electron linacs, since the 1970's. Higher intensity beams available in the last decade allow extending the use of beam imaging techniques to perform precise measurements of important beam parameters such as emittance, energy, and energy spread using optical transition radiation (OTR). OTR-based diagnostics systems are extensively used on the superconducting TESLA Test Facility (TTF) linac driving the vacuum ultraviolet free electron laser (VUV-FEL) at the Deutsches Elektronen-Synchrotron facility. Up to 30 optical diagnostic stations have been installed at various positions along the 250-m-long linac, each equipped with a high-performance digital camera. This paper describes the new approach to the design of the hardware and software setups required by the complex topology of such a distributed camera system

  8. Telerobotic virtual control system

    Science.gov (United States)

    Zhai, Shumin; Milgram, Paul

    1992-03-01

    A project to develop a telerobotic `virtual control' capability, currently underway at the University of Toronto, is described. The project centers on a new mode of interactive telerobotic control based on the technology of combining computer generated stereographic images with remotely transmitted stereoscopic video images. A virtual measurement technique, in conjunction with a basic level of digital image processing, comprising zooming, parallax adjustment, edge enhancement, and edge detection has been developed to assist the human operator in visualization of the remote environment and in spatial reasoning. The aim is to maintain target recognition, tactical planning, and high-level control functions in the hands of the human operator with the computer performing low-level computation and control. Control commands initiated by the operator are implemented through manipulation of a virtual image of the robot system, merged with a live video image of the remote scene. This paper discusses the philosophy and objectives of the project, with emphasis on the underlying human factor considerations in the design, and reports the progress made to date in this effort.

  9. Control rod drive system

    International Nuclear Information System (INIS)

    The present invention concerns an electromotive driving-type control rod driving system of a BWR type reactor, for which sliding resistance (friction) test can be performed of a movable portion of the control rod driving mechanisms. Namely, a hydraulic pressure control unit has following constitutions in addition to a conventional constitution as a sliding resistance test performing function. (1) A restricting valve is disposed downstream of the scram valve of scram pipelines to control flow rate and pressure of pressurized water flown in the pipelines. (2) A pressure gauge detects a pressure between the scram valve and the restricting valve. (3) A flow meter detects the flow rate of pipelines controlled by the restricting valve. (4) A recording pressure detector detects the pressure at the downstream of the restricting valve. (5) The recording device is attached when the sliding resistant test is performed for tracing the pressure measured by the pressure detection device. Further, the scram valve sends electric signals to a central operation chamber when it is fully closed. The central operation chamber has a function of fully opening the restricting valve by way of the electric signals. (I.S.)

  10. Upgrade of Beam Energy Measurement System at BEPC-II

    CERN Document Server

    Zhang, Jian-Yong; Mo, Xiao-Hu; Guo, Di-Zhou; Wang, Jian-Li; Liu, Bai-Qi; Achasov, M N; Krasnov, A A; Muchnoi, N Yu; Pyata, E E; Mamoshkina, E V; Harris, F A

    2015-01-01

    The beam energy measurement system is of great importance and profit for both BEPC-II accelerator and BES-III detector. The system is based on measuring the energies of Compton back-scattered photons. Many advanced techniques and precise instruments are employed to realize the highly accurate measurement of positron/electron beam energy. During five year's running period, in order to meet the requirement of data taking and improve the capacity of measurement itself, the upgradation of system is continued, which involve the component reformation of laser and optics subsystem, replacement of view-port of the laser to vacuum insertion subsystem, the purchase of electric cooling system for high purity germanium detector, and the improvement of data acquisition and processing subsystem. The upgrading of system guarantees the smooth and efficient measuring of beam energy at BEPC-II and accommodates the accurate offline energy values for further physics analysis at BES-III.

  11. Observations and control of beam instabilities due to higher order modes in Indus-2

    International Nuclear Information System (INIS)

    In a synchrotron radiation source (SRS), the interaction between electron beam spectra and Higher Order Modes (HOMs) of RF cavities may give rise to coupled bunch instabilities. These instabilities may limit beam current and beam lifetime. Indus-2 SRS has four RF cavities equipped with precision temperature controller of cooling system and Higher Order Mode Frequency Shifter (HOMFS) to avoid harmful HOMs. Offline (i.e. without beam) and Online (i.e. with beam) measurements, observations and analysis of HOMs have been performed. Some of the Longitudinal modes such as L1 (∼ 950 MHz), L3 (∼ 1432 MHz), L4 (∼ 1521 MHz), L5 (∼1628 MHz) were observed to be quite prominent at specific operating conditions. Based on these studies, harmful HOMs were identified and suitable methods were evolved to avoid these HOMs. Experiments were performed to achieve high beam current in Indus-2. The precision chiller temperatures and HOMFS positions were set as per theoretical estimates and were further optimized in fine steps during experiments. With the optimized settings, beam current around 200 mA at Injection energy (550 MeV) and 157 mA at 2.5 GeV has been successfully achieved. At these settings of RF cavity water temperature and HOMFS, harmful HOMs were within safe limits during regular operation of Indus-2 at 2.5 GeV/100 mA in user mode for more than one year. In this paper, important observations, analysis and experiments to avoid harmful HOMs of RF cavities are presented. (author)

  12. Combined hydrogen and lithium beam emission spectroscopy observation system for Korea Superconducting Tokamak Advanced Research.

    Science.gov (United States)

    Lampert, M; Anda, G; Czopf, A; Erdei, G; Guszejnov, D; Kovácsik, Á; Pokol, G I; Réfy, D; Nam, Y U; Zoletnik, S

    2015-07-01

    A novel beam emission spectroscopy observation system was designed, built, and installed onto the Korea Superconducting Tokamak Advanced Research tokamak. The system is designed in a way to be capable of measuring beam emission either from a heating deuterium or from a diagnostic lithium beam. The two beams have somewhat complementary capabilities: edge density profile and turbulence measurement with the lithium beam and two dimensional turbulence measurement with the heating beam. Two detectors can be used in parallel: a CMOS camera provides overview of the scene and lithium beam light intensity distribution at maximum few hundred Hz frame rate, while a 4 × 16 pixel avalanche photo-diode (APD) camera gives 500 kHz bandwidth data from a 4 cm × 16 cm region. The optics use direct imaging through lenses and mirrors from the observation window to the detectors, thus avoid the use of costly and inflexible fiber guides. Remotely controlled mechanisms allow adjustment of the APD camera's measurement location on a shot-to-shot basis, while temperature stabilized filter holders provide selection of either the Doppler shifted deuterium alpha or lithium resonance line. The capabilities of the system are illustrated by measurements of basic plasma turbulence properties. PMID:26233377

  13. Combined hydrogen and lithium beam emission spectroscopy observation system for Korea Superconducting Tokamak Advanced Research

    International Nuclear Information System (INIS)

    A novel beam emission spectroscopy observation system was designed, built, and installed onto the Korea Superconducting Tokamak Advanced Research tokamak. The system is designed in a way to be capable of measuring beam emission either from a heating deuterium or from a diagnostic lithium beam. The two beams have somewhat complementary capabilities: edge density profile and turbulence measurement with the lithium beam and two dimensional turbulence measurement with the heating beam. Two detectors can be used in parallel: a CMOS camera provides overview of the scene and lithium beam light intensity distribution at maximum few hundred Hz frame rate, while a 4 × 16 pixel avalanche photo-diode (APD) camera gives 500 kHz bandwidth data from a 4 cm × 16 cm region. The optics use direct imaging through lenses and mirrors from the observation window to the detectors, thus avoid the use of costly and inflexible fiber guides. Remotely controlled mechanisms allow adjustment of the APD camera’s measurement location on a shot-to-shot basis, while temperature stabilized filter holders provide selection of either the Doppler shifted deuterium alpha or lithium resonance line. The capabilities of the system are illustrated by measurements of basic plasma turbulence properties

  14. Combined hydrogen and lithium beam emission spectroscopy observation system for Korea Superconducting Tokamak Advanced Research

    Energy Technology Data Exchange (ETDEWEB)

    Lampert, M. [Wigner RCP, Euratom Association-HAS, Budapest (Hungary); BME NTI, Budapest (Hungary); Anda, G.; Réfy, D.; Zoletnik, S. [Wigner RCP, Euratom Association-HAS, Budapest (Hungary); Czopf, A.; Erdei, G. [Department of Atomic Physics, BME IOP, Budapest (Hungary); Guszejnov, D.; Kovácsik, Á.; Pokol, G. I. [BME NTI, Budapest (Hungary); Nam, Y. U. [National Fusion Research Institute, Daejeon (Korea, Republic of)

    2015-07-15

    A novel beam emission spectroscopy observation system was designed, built, and installed onto the Korea Superconducting Tokamak Advanced Research tokamak. The system is designed in a way to be capable of measuring beam emission either from a heating deuterium or from a diagnostic lithium beam. The two beams have somewhat complementary capabilities: edge density profile and turbulence measurement with the lithium beam and two dimensional turbulence measurement with the heating beam. Two detectors can be used in parallel: a CMOS camera provides overview of the scene and lithium beam light intensity distribution at maximum few hundred Hz frame rate, while a 4 × 16 pixel avalanche photo-diode (APD) camera gives 500 kHz bandwidth data from a 4 cm × 16 cm region. The optics use direct imaging through lenses and mirrors from the observation window to the detectors, thus avoid the use of costly and inflexible fiber guides. Remotely controlled mechanisms allow adjustment of the APD camera’s measurement location on a shot-to-shot basis, while temperature stabilized filter holders provide selection of either the Doppler shifted deuterium alpha or lithium resonance line. The capabilities of the system are illustrated by measurements of basic plasma turbulence properties.

  15. Electron beam diagnostic system using computed tomography and an annular sensor

    Energy Technology Data Exchange (ETDEWEB)

    Elmer, John W.; Teruya, Alan T.

    2015-08-11

    A system for analyzing an electron beam including a circular electron beam diagnostic sensor adapted to receive the electron beam, the circular electron beam diagnostic sensor having a central axis; an annular sensor structure operatively connected to the circular electron beam diagnostic sensor, wherein the sensor structure receives the electron beam; a system for sweeping the electron beam radially outward from the central axis of the circular electron beam diagnostic sensor to the annular sensor structure wherein the electron beam is intercepted by the annular sensor structure; and a device for measuring the electron beam that is intercepted by the annular sensor structure.

  16. Electron beam diagnostic system using computed tomography and an annular sensor

    Science.gov (United States)

    Elmer, John W.; Teruya, Alan T.

    2014-07-29

    A system for analyzing an electron beam including a circular electron beam diagnostic sensor adapted to receive the electron beam, the circular electron beam diagnostic sensor having a central axis; an annular sensor structure operatively connected to the circular electron beam diagnostic sensor, wherein the sensor structure receives the electron beam; a system for sweeping the electron beam radially outward from the central axis of the circular electron beam diagnostic sensor to the annular sensor structure wherein the electron beam is intercepted by the annular sensor structure; and a device for measuring the electron beam that is intercepted by the annular sensor structure.

  17. Beam transport optics for high-power laser systems

    International Nuclear Information System (INIS)

    Beam transport optics receive output energy from the laser cavity and deliver it to the work site. Depending on the application, this may require a few simple elements or large complex systems. Collection of the laser energy depends on the spatial and temporal energy distribution as well as the wavelength and polarization of the laser cavity and output coupler. Transport optics can perform a variety of functions, including beam formatting, frequency doubling, and distribution to one or more work sites while maintaining or even improving the beam quality. The beam may be delivered to work sites as focused spots or images, projected to distant targets, or propagated through various media for sensing or photochemical processing. Design may involve optical modeling of the system, including diffraction effects and thermal management. A Gaussian beam profile is often used for convenience in modeling. When deviations from this ideal profile need to be considered, it is necessary to characterize the laser beam in detail. Design of the transport system requires understanding of the interaction of the laser energy with optical materials and components. Practical considerations include mounting the optics without stress and with the stability suitable for the intended application. Requirements for beam direction, stability, size, shape, and quality dictate the design approach for each specific situation. Attention also must be given to reliability, environmental, and commercial requirements. Damage to optics in high-power laser systems is a common concern. Environmental problems such as atmospheric turbulence, contamination by dust or vapor from the work site or other sources, or absorption of water vapor can directly degrade beam quality. Other potentially significant optical performance effects may result from instability and aging of the optics, temperature, humidity, pressure, transmitted vibration, and contamination from the work site or other sources

  18. Beam commissioning of KEKB crab cavity RF system

    International Nuclear Information System (INIS)

    KEKB started the first crab crossing operation in February 2007 with two superconducting crab cavities. After four months operation dedicated for machine tuning, physics run with high-current beams resumed in October with the crab crossing. The crab cavities have been working stably for one and a half years. The crab cavity RF system, commissioning process and performance of the crab cavities with high-current beams are presented. (author)

  19. Electron beam energy stabilization using a neural network hybrid controller at the Australian Synchrotron Linac

    International Nuclear Information System (INIS)

    This paper describes the implementation of a neural network hybrid controller for energy stabilization at the Australian Synchrotron Linac. The structure of the controller consists of a neural network (NNET) feed forward control, augmented by a conventional Proportional-Integral (PI) feedback controller to ensure stability of the system. The system is provided with past states of the machine in order to predict its future state, and therefore apply appropriate feed forward control. The NNET is able to cancel multiple frequency jitter in real-time. When it is not performing optimally due to jitter changes, the system can successfully be augmented by the PI controller to attenuate the remaining perturbations. With a view to control the energy and bunch length at the FERMI(at)Elettra Free Electron Laser (FEL), the present study considers a neural network hybrid feed forward-feedback type of control to rectify limitations related to feedback systems, such as poor response for high jitter frequencies or limited bandwidth, while ensuring robustness of control. The Australian Synchrotron Linac is equipped with a beam position monitor (BPM), that was provided by Sincrotrone Trieste from a former transport line thus allowing energy measurements and energy control experiments. The present study will consequently focus on correcting energy jitter induced by variations in klystron phase and voltage.

  20. Electron beam energy stabilization using a neural network hybrid controller at the Australian Synchrotron Linac.

    Energy Technology Data Exchange (ETDEWEB)

    Meier, E.; Morgan, M. J.; Biedron, S. G.; LeBlanc, G.; Wu, J. (OTD-ESE); (Monash Univ.); (Australian Synchrotron Project); (SLAC National Accelerator Lab.)

    2009-01-01

    This paper describes the implementation of a neural network hybrid controller for energy stabilization at the Australian Synchrotron Linac. The structure of the controller consists of a neural network (NNET) feed forward control, augmented by a conventional Proportional-Integral (PI) feedback controller to ensure stability of the system. The system is provided with past states of the machine in order to predict its future state, and therefore apply appropriate feed forward control. The NNET is able to cancel multiple frequency jitter in real-time. When it is not performing optimally due to jitter changes, the system can successfully be augmented by the PI controller to attenuate the remaining perturbations. With a view to control the energy and bunch length at the FERMI{at}Elettra Free Electron Laser (FEL), the present study considers a neural network hybrid feed forward-feedback type of control to rectify limitations related to feedback systems, such as poor response for high jitter frequencies or limited bandwidth, while ensuring robustness of control. The Australian Synchrotron Linac is equipped with a beam position monitor (BPM), that was provided by Sincrotrone Trieste from a former transport line thus allowing energy measurements and energy control experiments. The present study will consequently focus on correcting energy jitter induced by variations in klystron phase and voltage.