WorldWideScience

Sample records for beam adjustment method

  1. Drive Beam Quadrupoles for the CLIC Project: a Novel Method of Fiducialisation and a New Micrometric Adjustment System

    CERN Document Server

    AUTHOR|(SzGeCERN)411678; Duquenne, Mathieu; Sandomierski, Jacek; Sosin, Mateusz; Rude, Vivien

    2014-01-01

    This paper presents a new method of fiducialisation applied to determine the magnetic axis of the Drive Beam quadrupole of the CLIC project with respect to external alignment fiducials, within a micrometric accuracy and precision. It introduces also a new micrometric adjustment system along 5 Degrees of Freedom, developed for the same Drive Beam quadrupole. The combination of both developments opens very interesting perspectives to get a more simple and accurate alignment of the quadrupoles.

  2. Adjustable magnification anamorphic beam expander

    Science.gov (United States)

    Escobar, S. R.

    1990-08-01

    A visible laser diode package is proposed to substitute a Krpton-Ion laser for alignment purposes. The proposed system uses 5 Melles Griot AR coated stock lenses. Tests performed to the optics reveal some undesirable properties, such as, astigmatism and spherical aberration; however, the interference pattern and star test reveals what seems to be a good quality wavefront. The interference fringes seem to be very good, but there still is a small presence of a comalike aberration at the fringes extreme. The star test revealed the system to be about 3 times diffraction limited. The system has yet to be tested in an alignment situation. As for now, it is ready to be tested with some minor alignment adjustments necessary for a good wavefront quality. A safety memo was written for testing the prototype system at the alignment lab. The initial laser diode system alignment method suggested, uses a reverse alignment procedure. In this procedure, the expected output (30 mm diameter beam) is input into the system output and alignment is performed by moving the components until the desired system input is found; an elliptical beam with 1 mm in the horizontal axis and 4 mm in the vertical axis. Once this reverse alignment procedure is completed the laser diode is placed at the system input. Fine alignment is done with the help of shear plate interference patterns in both, the 1 mm axis and 4 mm axis. The proposed final opto-mechanical packaging of this system is formed with squared adapter plates that are connected by means of four support rods where the center of the plate becomes the optical axis. These components are commercially available and provide high mechanical stability.

  3. Adjustable hollow-cone output x-ray beam from an ellipsoidal monocapillary with a pinhole and a beam stop.

    Science.gov (United States)

    Sun, Xue-Peng; Liu, Zhi-Gou; Yi, Long-Tao; Sun, Wei-Yun; Li, Fang-Zou; Jiang, Bo-Wen; Ma, Yong-Zhong; Sun, Tian-Xi

    2015-12-10

    A combined shading system (CSS) consisting of a beam stop and a pinhole is proposed to be used between an ellipsoidal monocapillary (EM) and a conventional laboratory x-ray source to obtain an adjustable hollow-cone output beam for different experiments with no need for changing the EM. The CSS can change the incident x-ray beam on the EM by adjusting the position of the beam stop and the pinhole, with the corresponding change of the output beam of the EM. In this study, the adjustable hollow-cone output x-ray beam of an 80-mm-long EM with a CSS was studied in detail with a laboratory Cu x-ray generator with a focal spot diameter of 50 μm. The adjustable range of the focal spot size of the EM was from 8.6 to 58.7 μm. The adjustable range of the gain of the focal spot of the EM was from 0 to 1350. The beam divergence of the hollow-cone output beam of the EM ranged from 6 to 16.75 mrad. The illumination angle of the hollow-cone output beam of the EM ranged from 0 to 5.95 mrad. In addition, the potential application of the proposed adjusting method in testing the performance of the EM is briefly discussed.

  4. Dwell time adjustment for focused ion beam machining

    International Nuclear Information System (INIS)

    Taniguchi, Jun; Satake, Shin-ichi; Oosumi, Takaki; Fukushige, Akihisa; Kogo, Yasuo

    2013-01-01

    Focused ion beam (FIB) machining is potentially useful for micro/nano fabrication of hard brittle materials, because the removal method involves physical sputtering. Usually, micro/nano scale patterning of hard brittle materials is very difficult to achieve by mechanical polishing or dry etching. Furthermore, in most reported examples, FIB machining has been applied to silicon substrates in a limited range of shapes. Therefore, a versatile method for FIB machining is required. We previously established the dwell time adjustment for mechanical polishing. The dwell time adjustment is calculated by using a convolution model derived from Preston’s hypothesis. More specifically, the target removal shape is a convolution of the unit removal shape, and the dwell time is calculated by means of one of four algorithms. We investigate these algorithms for dwell time adjustment in FIB machining, and we found that a combination a fast Fourier transform calculation technique and a constraint-type calculation is suitable. By applying this algorithm, we succeeded in machining a spherical lens shape with a diameter of 2.93 μm and a depth of 203 nm in a glassy carbon substrate by means of FIB with dwell time adjustment

  5. Method for energy recovery of spent ERL beams

    Energy Technology Data Exchange (ETDEWEB)

    Marhauser, Frank; Hannon, Fay; Rimmer, Robert; Whitney, R. Roy

    2018-01-16

    A method for recovering energy from spent energy recovered linac (ERL) beams. The method includes adding a plurality of passive decelerating cavities at the beam dump of the ERL, adding one or more coupling waveguides between the passive decelerating cavities, setting an adequate external Q (Qext) to adjust to the beam loading situation, and extracting the RF energy through the coupling waveguides.

  6. Systems and methods of varying charged particle beam spot size

    Science.gov (United States)

    Chen, Yu-Jiuan

    2014-09-02

    Methods and devices enable shaping of a charged particle beam. A modified dielectric wall accelerator includes a high gradient lens section and a main section. The high gradient lens section can be dynamically adjusted to establish the desired electric fields to minimize undesirable transverse defocusing fields at the entrance to the dielectric wall accelerator. Once a baseline setting with desirable output beam characteristic is established, the output beam can be dynamically modified to vary the output beam characteristics. The output beam can be modified by slightly adjusting the electric fields established across different sections of the modified dielectric wall accelerator. Additional control over the shape of the output beam can be excreted by introducing intentional timing de-synchronization offsets and producing an injected beam that is not fully matched to the entrance of the modified dielectric accelerator.

  7. Electron Beam Adjustment in PLATO RTS 2 Including the Effect of Air Gaps

    CERN Document Server

    Lopes, M C; Trindade, A; Rodrigues, P; Peralta, L

    2002-01-01

    Background and Purpose: Beam characterization for electron dose calculations in PLATO RTS 2 treatment planning system requires the tuning of two adjustment parameters: sqx (the initial angular spread) and FMCS (a "fudge" multiple Coulomb scattering parameter). This work provides a set of suggestions to optimise electron dose calculations with PLATO, taking into account the effect of air gaps between the electron applicator and the patient skin. Material and Methods: Two adjustment criteria have been followed: one which uses just one input data set corresponding to the standard (null) air gap and another one that takes into account the whole range of clinically used distances between the electron applicator and the patient surface. The adjusted values of sqx were compared with experimental data and GEANT3 Monte Carlo code results. A systematic study has been carried out of the effect of both adjustment parameters on electron dose calculations in water. Comparisons of dose distributions and point dose values ha...

  8. Simple method for generating adjustable trains of picosecond electron bunches

    Directory of Open Access Journals (Sweden)

    P. Muggli

    2010-05-01

    Full Text Available A simple, passive method for producing an adjustable train of picosecond electron bunches is demonstrated. The key component of this method is an electron beam mask consisting of an array of parallel wires that selectively spoils the beam emittance. This mask is positioned in a high magnetic dispersion, low beta-function region of the beam line. The incoming electron beam striking the mask has a time/energy correlation that corresponds to a time/position correlation at the mask location. The mask pattern is transformed into a time pattern or train of bunches when the dispersion is brought back to zero downstream of the mask. Results are presented of a proof-of-principle experiment demonstrating this novel technique that was performed at the Brookhaven National Laboratory Accelerator Test Facility. This technique allows for easy tailoring of the bunch train for a particular application, including varying the bunch width and spacing, and enabling the generation of a trailing witness bunch.

  9. Planar Heating Element Adjusted by Electron Beam Micromachining

    Czech Academy of Sciences Publication Activity Database

    Dupák, Libor; Dupák, Jan

    2009-01-01

    Roč. 44, 5-6 (2009), s. 82-84 ISSN 0861-4717 Institutional research plan: CEZ:AV0Z20650511 Keywords : electron beam machining * heating element Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering

  10. Modeling of an Adjustable Beam Solid State Light

    Data.gov (United States)

    National Aeronautics and Space Administration — This proposal is for the development of a computational model of a prototype variable beam light source using optical modeling software, Zemax OpticStudio ®. The...

  11. Methods of generation of molecular beams

    International Nuclear Information System (INIS)

    Kudryavtsev, N.N.; Mazyar, O.A.; Sukhov, A.M.

    1993-01-01

    In the work are reviewed methods of generation of molecular beams. Traditional effusive and gasodynamical sources of molecular beams are examined in detail, there is given their comparative analysis. Methods to obtain high-energy beams (>1 eV) intensively developing now are discussed in detail. A special attention is drawn to fast molecular beams containing atomic oxygen and applied for the study of physo-chemical processes on the solid surface

  12. Faraday cup with nanosecond response and adjustable impedance for fast electron beam characterization

    International Nuclear Information System (INIS)

    Hu Jing; Rovey, Joshua L.

    2011-01-01

    A movable Faraday cup design with simple structure and adjustable impedance is described in this work. This Faraday cup has external adjustable shunt resistance for self-biased measurement setup and 50 Ω characteristic impedance to match with 50 Ω standard BNC coaxial cable and vacuum feedthroughs for nanosecond-level pulse signal measurements. Adjustable shunt resistance allows self-biased measurements to be quickly acquired to determine the electron energy distribution function. The performance of the Faraday cup is validated by tests of response time and amplitude of output signal. When compared with a reference source, the percent difference of the Faraday cup signal fall time is less than 10% for fall times greater than 10 ns. The percent difference of the Faraday cup signal pulse width is below 6.7% for pulse widths greater than 10 ns. A pseudospark-generated electron beam is used to compare the amplitude of the Faraday cup signal with a calibrated F-70 commercial current transformer. The error of the Faraday cup output amplitude is below 10% for the 4-14 kV tested pseudospark voltages. The main benefit of this Faraday cup is demonstrated by adjusting the external shunt resistance and performing the self-biased method for obtaining the electron energy distribution function. Results from a 4 kV pseudospark discharge indicate a ''double-humped'' energy distribution.

  13. METHOD OF ELECTRON BEAM PROCESSING

    DEFF Research Database (Denmark)

    2003-01-01

    As a rule, electron beam welding takes place in a vacuum. However, this means that the workpieces in question have to be placed in a vacuum chamber and have to be removed therefrom after welding. This is time−consuming and a serious limitation of a process the greatest advantage of which is the o......As a rule, electron beam welding takes place in a vacuum. However, this means that the workpieces in question have to be placed in a vacuum chamber and have to be removed therefrom after welding. This is time−consuming and a serious limitation of a process the greatest advantage of which...... is the option of welding workpieces of large thicknesses. Therefore the idea is to guide the electron beam (2) to the workpiece via a hollow wire, said wire thereby acting as a prolongation of the vacuum chamber (4) down to workpiece. Thus, a workpiece need not be placed inside the vacuum chamber, thereby...... exploiting the potential of electron beam processing to a greater degree than previously possible, for example by means of electron beam welding...

  14. Ion beam sputter implantation method

    International Nuclear Information System (INIS)

    King, W.J.

    1978-01-01

    By means of ion beam atomizing or sputtering an integrally composed coating, the composition of which continuously changes from 100% of the substrate to 100% of the coating, can be surfaced on a substrate (e.g. molten quartz on plastic lenses). In order to do this in the facility there is directed a primary beam of accelerated noble gas ions on a target from the group of the following materials: SiO 2 , Al 2 O 3 , Corning Glass 7070, Corning Glass 7740 or borosilicate glass. The particles leaving the target are directed on the substrate by means of an acceleration potential of up to 10 KV. There may, however, be coated also metal layers (Ni, Co) on a mylar film resulting in a semireflecting metal film. (RW) [de

  15. 2D potential measurements by applying automatic beam adjustment system to heavy ion beam probe diagnostic on the Large Helical Device

    International Nuclear Information System (INIS)

    Shimizu, A.; Ido, T.; Kato, S.; Hamada, Y.; Kurachi, M.; Makino, R.; Nishiura, M.; Nishizawa, A.

    2014-01-01

    Two-dimensional potential profiles in the Large Helical Device (LHD) were measured with heavy ion beam probe (HIBP). To measure the two-dimensional profile, the probe beam energy has to be changed. However, this task is not easy, because the beam transport line of LHD-HIBP system is very long (∼20 m), and the required beam adjustment consumes much time. To reduce the probe beam energy adjustment time, an automatic beam adjustment system has been developed. Using this system, required time to change the probe beam energy is dramatically reduced, such that two-dimensional potential profiles were able to be successfully measured with HIBP by changing the probe beam energy shot to shot

  16. Method for Adjusting the Anger Camera

    International Nuclear Information System (INIS)

    Oberhausen, E.; Neumann, K. J.; Schiffler, W.

    1969-01-01

    The uniformity of the Anger camera is a basic condition for the interpretation of scintiphotos and its importance increases with the accuracy of the evaluation method used for the interpretation of the scintiphotos. This is especially true for the use of three-dimensional multichannel-analysers with quantitative data output. With the standard method, used until now, all photo multipliers are tuned to give the same coun t-ra te when the crystal close to the centre of each photomultiplier is irradiatedby a collimated source. If there after the crystal is irradiated by a uniform flux of gamma rays, the density of the dots increases from the centre of the scintiphoto towards the outer edge. This means that uniformity has not been achieved. In clinical use hot spots would be simulated for those parts of an organ that are visualized at the outer part of the crystal. By using the magnetic core memory of a multichannel analyser for quantitative evaluation of the scintiphotos, we developed a method by which the photomultipliers are tuned with respect to their geometrical position. Thus, it is possible to achieve a uniformity within a few per cent over the whole crystal. The method and its theory are discussed. Data for the resolution of the Anger camera after this tuning process are given. (author)

  17. Ion-optical studies for a range adaptation method in ion beam therapy using a static wedge degrader combined with magnetic beam deflection

    International Nuclear Information System (INIS)

    Chaudhri, Naved; Saito, Nami; Bert, Christoph; Franczak, Bernhard; Steidl, Peter; Durante, Marco; Schardt, Dieter; Rietzel, Eike

    2010-01-01

    Fast radiological range adaptation of the ion beam is essential when target motion is mitigated by beam tracking using scanned ion beams for dose delivery. Electromagnetically controlled deflection of a well-focused ion beam on a small static wedge degrader positioned between two dipole magnets, inside the beam delivery system, has been considered as a fast range adaptation method. The principle of the range adaptation method was tested in experiments and Monte Carlo simulations for the therapy beam line at the GSI Helmholtz Centre for Heavy Ions Research. Based on the simulations, ion optical settings of beam deflection and realignment of the adapted beam were experimentally applied to the beam line, and additional tuning was manually performed. Different degrader shapes were employed for the energy adaptation. Measured and simulated beam profiles, i.e. lateral distribution and range in water at isocentre, were analysed and compared with the therapy beam values for beam scanning. Deflected beam positions of up to ±28 mm on degrader were performed which resulted in a range adaptation of up to ±15 mm water equivalence (WE). The maximum deviation between the measured adapted range from the nominal range adaptation was below 0.4 mm WE. In experiments, the width of the adapted beam at the isocentre was adjustable between 5 and 11 mm full width at half maximum. The results demonstrate the feasibility/proof of the proposed range adaptation method for beam tracking from the beam quality point of view.

  18. Ion-optical studies for a range adaptation method in ion beam therapy using a static wedge degrader combined with magnetic beam deflection

    Science.gov (United States)

    Chaudhri, Naved; Saito, Nami; Bert, Christoph; Franczak, Bernhard; Steidl, Peter; Durante, Marco; Rietzel, Eike; Schardt, Dieter

    2010-06-01

    Fast radiological range adaptation of the ion beam is essential when target motion is mitigated by beam tracking using scanned ion beams for dose delivery. Electromagnetically controlled deflection of a well-focused ion beam on a small static wedge degrader positioned between two dipole magnets, inside the beam delivery system, has been considered as a fast range adaptation method. The principle of the range adaptation method was tested in experiments and Monte Carlo simulations for the therapy beam line at the GSI Helmholtz Centre for Heavy Ions Research. Based on the simulations, ion optical settings of beam deflection and realignment of the adapted beam were experimentally applied to the beam line, and additional tuning was manually performed. Different degrader shapes were employed for the energy adaptation. Measured and simulated beam profiles, i.e. lateral distribution and range in water at isocentre, were analysed and compared with the therapy beam values for beam scanning. Deflected beam positions of up to ±28 mm on degrader were performed which resulted in a range adaptation of up to ±15 mm water equivalence (WE). The maximum deviation between the measured adapted range from the nominal range adaptation was below 0.4 mm WE. In experiments, the width of the adapted beam at the isocentre was adjustable between 5 and 11 mm full width at half maximum. The results demonstrate the feasibility/proof of the proposed range adaptation method for beam tracking from the beam quality point of view.

  19. Adjustable static and dynamic actuation of clamped-guided beams using electrothermal axial loads

    KAUST Repository

    Alcheikh, Nouha

    2018-02-14

    The paper presents adjustable static and dynamic actuations of in-plane clamped-guided beams. The structures, of variable stiffness, can be used as highly tunable resonators and actuators. Axial loads are applied through electrothermal U-shaped and flexure beams actuators stacked near the edges of curved (arch) beams. The electrothermal actuators can be configurred in various ways to adjust as desired the mechanical stiffness of the structures; thereby controlling their deformation stroke as actuators and their operating resonance frequency as resonators. The experimental and finite element results demonstrate the flexibility of the designs in terms of static displacements and resonance frequencies of the first and second symmetric modes of the arches. The results show considerable increase in the resonance frequency and deflection of the microbeam upon changing end actuation conditions, which can be promising for low voltage actuation and tunable resonators applications, such as filters and memory devices. As case studies of potential device configurations of the proposed design, we demonstrate eight possibilities of achieving new static and dynamic behaviors, which produce various resonance frequencies and static displacement curves. The ability to actively shift the entire frequency response curve of a device is desirable for several applications to compensate for in-use anchor degradations and deformations. As an example, we experimentally demonstrate using the device as a resonant logic gate, with active resonance tuning, showing fundamental 2-bit logic functions, such as AND,XOR, and NOR.

  20. An updated method for risk adjustment in outcomes research.

    Science.gov (United States)

    Doi, Suhail A R; Barendregt, Jan J; Rao, Chalapati

    2014-07-01

    To demonstrate why meta-analytic methods need modification before they can be used to aggregate rates or effect sizes in outcomes research, under the constraint of no common underlying effect or rate. Studies are presented that require different types of risk adjustment. First, we demonstrate using rates that external risk adjustment through standardization can be achieved using modified meta-analytic methods, but only with a model that allows input of user-defined weights. Next, we extend these observations to internal risk adjustment of comparative effect sizes. We show that this procedure produces identical results to conventional age standardization if a rate is being standardized for age. We also demonstrate that risk adjustment of effect sizes can be achieved with this modified method but cannot be done using standard meta-analysis. We conclude that this method allows risk adjustment to be performed in situations in which currently the fixed- or random-effects methods of meta-analysis are inappropriately used. The latter should be avoided when the underlying aim is risk adjustment rather than meta-analysis. Copyright © 2014 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  1. Control of beam halo-chaos using neural network self-adaptation method

    International Nuclear Information System (INIS)

    Fang Jinqing; Huang Guoxian; Luo Xiaoshu

    2004-11-01

    Taking the advantages of neural network control method for nonlinear complex systems, control of beam halo-chaos in the periodic focusing channels (network) of high intensity accelerators is studied by feed-forward back-propagating neural network self-adaptation method. The envelope radius of high-intensity proton beam is reached to the matching beam radius by suitably selecting the control structure of neural network and the linear feedback coefficient, adjusted the right-coefficient of neural network. The beam halo-chaos is obviously suppressed and shaking size is much largely reduced after the neural network self-adaptation control is applied. (authors)

  2. The tension adjuster used at the work line of electron beam radiation cross-linking wire and cable

    International Nuclear Information System (INIS)

    Zhang Yingfa; Liu Zhenhao; Yin Xuejun

    1999-01-01

    The tension adjuster is an important equipment in the transport system at the work line of electron beam radiation cross-linking wire and cable to realize the velocity synchronism. There are many kinds of the adjuster. By putting various adjusters together properly, the authors can keep the line work stable and raise the quality of the product. Two kinds of standing adjuster and their mechanism are introduced. Also the corresponding figures and formulas are shown

  3. Beam imaging sensor and method for using same

    Science.gov (United States)

    McAninch, Michael D.; Root, Jeffrey J.

    2017-01-03

    The present invention relates generally to the field of sensors for beam imaging and, in particular, to a new and useful beam imaging sensor for use in determining, for example, the power density distribution of a beam including, but not limited to, an electron beam or an ion beam. In one embodiment, the beam imaging sensor of the present invention comprises, among other items, a circumferential slit that is either circular, elliptical or polygonal in nature. In another embodiment, the beam imaging sensor of the present invention comprises, among other things, a discontinuous partially circumferential slit. Also disclosed is a method for using the various beams sensor embodiments of the present invention.

  4. Seasonal adjustment methods and real time trend-cycle estimation

    CERN Document Server

    Bee Dagum, Estela

    2016-01-01

    This book explores widely used seasonal adjustment methods and recent developments in real time trend-cycle estimation. It discusses in detail the properties and limitations of X12ARIMA, TRAMO-SEATS and STAMP - the main seasonal adjustment methods used by statistical agencies. Several real-world cases illustrate each method and real data examples can be followed throughout the text. The trend-cycle estimation is presented using nonparametric techniques based on moving averages, linear filters and reproducing kernel Hilbert spaces, taking recent advances into account. The book provides a systematical treatment of results that to date have been scattered throughout the literature. Seasonal adjustment and real time trend-cycle prediction play an essential part at all levels of activity in modern economies. They are used by governments to counteract cyclical recessions, by central banks to control inflation, by decision makers for better modeling and planning and by hospitals, manufacturers, builders, transportat...

  5. Arsenic and Obesity: A Comparison of Urine Dilution Adjustment Methods.

    Science.gov (United States)

    Bulka, Catherine M; Mabila, Sithembile L; Lash, James P; Turyk, Mary E; Argos, Maria

    2017-08-28

    A commonly used approach to adjust for urine dilution in analyses of biomarkers is to adjust for urinary creatinine. However, creatinine is a product of muscle mass and is therefore associated with body mass. In studies of urinary analytes and obesity or obesity-related outcomes, controlling for creatinine could induce collider stratification bias. We illustrate this phenomenon with an analysis of urinary arsenic. We aimed to evaluate various approaches of adjustment for urinary dilution on the associations between urinary arsenic concentration and measures of obesity. Using data from the National Health and Nutrition Examination Survey, we regressed body mass index (BMI) and waist-to-height ratios on urinary arsenic concentrations. We compared eight approaches to account for urine dilution, including standardization by urinary creatinine, osmolality, and flow rates, and inclusion of these metrics as independent covariates. We also used a recently proposed method known as covariate-adjusted standardization. Inverse associations between urinary arsenic concentration with BMI and waist-to-height ratio were observed when either creatinine or osmolality were used to standardize or as covariates. Not adjusting for dilution, standardizing or adjusting for urinary flow rate, and using covariate-adjusted standardization resulted in null associations observed between arsenic concentration in relation to BMI and waist-to-height ratio. Our findings suggest that arsenic exposure is not associated with obesity, and that urinary creatinine and osmolality may be colliders on the causal pathway from arsenic exposure to obesity, as common descendants of hydration and body composition. In studies of urinary biomarkers and obesity or obesity-related outcomes, alternative metrics such as urinary flow rate or analytic strategies such as covariate-adjusted standardization should be considered. https://doi.org/10.1289/EHP1202.

  6. Analytical N beam position monitor method

    Science.gov (United States)

    Wegscheider, A.; Langner, A.; Tomás, R.; Franchi, A.

    2017-11-01

    Measurement and correction of focusing errors is of great importance for performance and machine protection of circular accelerators. Furthermore LHC needs to provide equal luminosities to the experiments ATLAS and CMS. High demands are also set on the speed of the optics commissioning, as the foreseen operation with β*-leveling on luminosity will require many operational optics. A fast measurement of the β -function around a storage ring is usually done by using the measured phase advance between three consecutive beam position monitors (BPMs). A recent extension of this established technique, called the N-BPM method, was successfully applied for optics measurements at CERN, ALBA, and ESRF. We present here an improved algorithm that uses analytical calculations for both random and systematic errors and takes into account the presence of quadrupole, sextupole, and BPM misalignments, in addition to quadrupolar field errors. This new scheme, called the analytical N-BPM method, is much faster, further improves the measurement accuracy, and is applicable to very pushed beam optics where the existing numerical N-BPM method tends to fail.

  7. Method for surface treatment by electron beams

    International Nuclear Information System (INIS)

    Panzer, S.; Doehler, H.; Bartel, R.; Ardenne, T. von.

    1985-01-01

    The invention has been aimed at simplifying the technology and saving energy in modifying surfaces with the aid of electron beams. The described beam-object geometry allows to abandon additional heat treatments. It can be used for surface hardening

  8. Stability Analysis of Nonuniform Rectangular Beams Using Homotopy Perturbation Method

    Directory of Open Access Journals (Sweden)

    Seval Pinarbasi

    2012-01-01

    Full Text Available The design of slender beams, that is, beams with large laterally unsupported lengths, is commonly controlled by stability limit states. Beam buckling, also called “lateral torsional buckling,” is different from column buckling in that a beam not only displaces laterally but also twists about its axis during buckling. The coupling between twist and lateral displacement makes stability analysis of beams more complex than that of columns. For this reason, most of the analytical studies in the literature on beam stability are concentrated on simple cases: uniform beams with ideal boundary conditions and simple loadings. This paper shows that complex beam stability problems, such as lateral torsional buckling of rectangular beams with variable cross-sections, can successfully be solved using homotopy perturbation method (HPM.

  9. Electron beam directed energy device and methods of using same

    Science.gov (United States)

    Retsky, Michael W.

    2007-10-16

    A method and apparatus is disclosed for an electron beam directed energy device. The device consists of an electron gun with one or more electron beams. The device includes one or more accelerating plates with holes aligned for beam passage. The plates may be flat or preferably shaped to direct each electron beam to exit the electron gun at a predetermined orientation. In one preferred application, the device is located in outer space with individual beams that are directed to focus at a distant target to be used to impact and destroy missiles. The aimings of the separate beams are designed to overcome Coulomb repulsion. A method is also presented for directing the beams to a target considering the variable terrestrial magnetic field. In another preferred application, the electron beam is directed into the ground to produce a subsurface x-ray source to locate and/or destroy buried or otherwise hidden objects including explosive devices.

  10. Survey and adjustment methods applied on an 11 axes high performance reflectometer for synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Eggenstein, F., E-mail: Frank.Eggenstein@helmholtz-berlin.de; Bischoff, P.; Schäfers, F.; Schroeter, T.; Senf, F.; Sokolov, A.; Zeschke, T.; Erko, A. [Helmholtz-Zentrum Berlin, Albert-Einstein-Str. 15, Berlin, Germany, D-12489 (Germany)

    2016-07-27

    At BESSY-II a new UV-and XUV optics beamline [1] has recently been setup with an in-house developed versatile reflectometer [2], [3], [4] for at-wavelength metrology on reflective and diffractive optical elements up to 4 kg mass. High precision measurements of the reflection and polarization properties are feasible by a 360° azimuthal rotation of the sample around the beam of light, where samples can be adjusted reproducibly with a novel UHV-Tripod within arc sec and μm precision. The azimuthal rotation requires an extremely high precision adjustment of the goniometer axis with respect to the incident light beam. Here we describe sophisticated methods with which we achieve nearly perfect agreement of the azimuthal rotation axis and the synchrotron beam in the 30 arc sec range. By using geodetic instruments (lasertracker, theodolite, autocollimator) the quality of the reflectometer UHV-mechanics has been characterized with respect to stiffness and radial run out with highest precision [5].

  11. Beam divergence correction method for neutron resonance spin echo spectroscope

    International Nuclear Information System (INIS)

    Maruyama, Ryuji; Tasaki, Seiji; Hino, Masahiro; Kitaguchi, Masaaki; Kawabata, Yuji; Ebisawa, Toru

    2005-01-01

    A beam divergence correction method for Neutron resonance spin echo (NRSE) spectroscope was proposed and the effectiveness is evaluated by simulation. When a beam divergence correction coil was introduced into NRSE spectroscope and the optimum magnetic field was given, the visibility of spin echo signal was recovered by controlling scattering of phase difference generated by beam divergence. The effectiveness of the correction method was proved by the above result. Principle of NRSE spectroscopy, decrease of spin polarization rate by beam divergence and its correction method, structure of divergence angle correction coil and the magnetic field calculation and result of simulation are described. (S.Y.)

  12. Gas flow parameter determination by molecular beam method

    International Nuclear Information System (INIS)

    Zarvin, A.E.; Sharafutdinov, R.G.

    1977-01-01

    This paper describes a molecular-beam system intended for studying nonequilibrium processes in supersonic rarefied gas flows. The system represented is a small molecular beam source placed inside the low intensity wind tunnel of the Institute of Thermophysics, Siberian Branch of the USSR Academy of Sciences. The time-of-flight method is used for measuring molecular velocity distribution functions on molecular beam axis. (Auth.)

  13. Information bias in health research: definition, pitfalls, and adjustment methods.

    Science.gov (United States)

    Althubaiti, Alaa

    2016-01-01

    As with other fields, medical sciences are subject to different sources of bias. While understanding sources of bias is a key element for drawing valid conclusions, bias in health research continues to be a very sensitive issue that can affect the focus and outcome of investigations. Information bias, otherwise known as misclassification, is one of the most common sources of bias that affects the validity of health research. It originates from the approach that is utilized to obtain or confirm study measurements. This paper seeks to raise awareness of information bias in observational and experimental research study designs as well as to enrich discussions concerning bias problems. Specifying the types of bias can be essential to limit its effects and, the use of adjustment methods might serve to improve clinical evaluation and health care practice.

  14. Control of quasi-monoenergetic electron beams from laser-plasma accelerators by adjusting shock density profile

    Science.gov (United States)

    Tsai, Hai-En; Swanson, Kelly K.; Lehe, Remi; Barber, Sam K.; Isono, Fumika; Otero, Jorge G.; Liu, Xinyao; Mao, Hann-Shin; Steinke, Sven; Tilborg, Jeroen Van; Geddes, Cameron G. R.; Leemans, Wim

    2017-10-01

    High-level control of a laser-plasma accelerator (LPA) using a shock injector was demonstrated by systematically varying the shock injector profile, including the shock angle, up-ramp width and shock position. Particle-in-cell (PIC) simulation explored how variations in the shock profile impacted the injection process and confirmed results obtained through acceleration experiments. These results establish that, by adjusting shock position, up-ramp, and angle, beam energy, energy spread, and pointing can be controlled. As a result, e-beam were highly tunable from 25 to 300 MeV with Administration, Defense Nuclear Nonproliferation R&D (NA22).

  15. Transverse Beam Profile Measurements Using Optical Methods

    CERN Document Server

    Peters, A; Weiss, A; Bank, A

    2001-01-01

    Two different systems are currently under development at GSI's heavy ion facility to measure transverse beam profiles using optical emitters. At the GSI-LINAC for energies up to 15 MeV/u residual gas fluorescence is investigated for pulsed high current beams. The fluorescence of N2 is monitored by an image intensified CCD camera. For all ion species with energies above 50 MeV/u slowly extracted from the synchrotron SIS a classical viewing screen system is used. Three different target materials have been investigated and their behavior concerning efficiency, saturation and timing performance is evaluated. Both systems (will) use CCD cameras with a digital read out using the IEEE 1394 standard.

  16. Method of determining the position of an irradiated electron beam

    International Nuclear Information System (INIS)

    Fukuda, Wataru.

    1967-01-01

    The present invention relates to the method of determining the position of a radiated electron beam, in particular, the method of detecting the position of a p-n junction by a novel method when irradiating the electron beam on to the semi-conductor wafer, controlling the position of the electron beam from said junction. When the electron beam is irradiated on to the semi-conductor wafer which possesses the p-n junction, the position of the p-n junction may be ascertained to determine the position of the irradiated electron beam by detecting the electromotive force resulting from said p-n junction with a metal disposed in the proximity of but without mechanical contact with said semi-conductor wafer. Furthermore, as far as a semi-conductor wafer having at least one p-n junction is concerned, the present invention allows said p-n junction to be used to determine the position of an irradiated electron beam. Thus, according to the present invention, the electromotive force of the electron beam resulting from the p-n junction may easily be detected by electrostatic coupling, enabling the position of the irradiated electron beam to be accurately determined. (Masui, R.)

  17. Large variation finite element method for beams with stochastic stiffness

    CERN Document Server

    Rollot, O

    2003-01-01

    The behavior of beams with stochastic stiffness subjected to either deterministic or stochastic loading is studied via finite element method. The results are contrasted with exact solution to check the accuracy of the FEM for the case of large variations. It represents a generalization of the previous study in which the stiffness matrix was decomposed as a product of three matrices, two of which are numerical ones and the third matrix involves the uncertain stiffness analytically. To illustrate the proposed method, we evaluate the mean and the auto-correlation functions of the displacement of beams under various boundary conditions. Two statically determinate beams (clamped-free or simply-supported) and two statically indeterminate beams (clamped-simply-supported or clamped are both ends) are investigated in this study. The beams are subjected to a deterministic uniform pressure or a stochastic excitation.

  18. Large variation finite element method for beams with stochastic stiffness

    International Nuclear Information System (INIS)

    Rollot, Olivier; Elishakoff, Isaac

    2003-01-01

    The behavior of beams with stochastic stiffness subjected to either deterministic or stochastic loading is studied via finite element method. The results are contrasted with exact solution to check the accuracy of the FEM for the case of large variations. It represents a generalization of the previous study in which the stiffness matrix was decomposed as a product of three matrices, two of which are numerical ones and the third matrix involves the uncertain stiffness analytically. To illustrate the proposed method, we evaluate the mean and the auto-correlation functions of the displacement of beams under various boundary conditions. Two statically determinate beams (clamped-free or simply-supported) and two statically indeterminate beams (clamped-simply-supported or clamped are both ends) are investigated in this study. The beams are subjected to a deterministic uniform pressure or a stochastic excitation

  19. Analytical Evaluation of Beam Deformation Problem Using Approximate Methods

    DEFF Research Database (Denmark)

    Barari, Amin; Kimiaeifar, A.; Domairry, G.

    2010-01-01

    The beam deformation equation has very wide applications in structural engineering. As a differential equation, it has its own problem concerning existence, uniqueness and methods of solutions. Often, original forms of governing differential equations used in engineering problems are simplified...

  20. LSL: a logarithmic least-squares adjustment method

    International Nuclear Information System (INIS)

    Stallmann, F.W.

    1982-01-01

    To meet regulatory requirements, spectral unfolding codes must not only provide reliable estimates for spectral parameters, but must also be able to determine the uncertainties associated with these parameters. The newer codes, which are more appropriately called adjustment codes, use the least squares principle to determine estimates and uncertainties. The principle is simple and straightforward, but there are several different mathematical models to describe the unfolding problem. In addition to a sound mathematical model, ease of use and range of options are important considerations in the construction of adjustment codes. Based on these considerations, a least squares adjustment code for neutron spectrum unfolding has been constructed some time ago and tentatively named LSL

  1. Differential quadrature method of nonlinear bending of functionally graded beam

    Science.gov (United States)

    Gangnian, Xu; Liansheng, Ma; Wang, Youzhi; Quan, Yuan; Weijie, You

    2018-02-01

    Using the third-order shear deflection beam theory (TBT), nonlinear bending of functionally graded (FG) beams composed with various amounts of ceramic and metal is analyzed utilizing the differential quadrature method (DQM). The properties of beam material are supposed to accord with the power law index along to thickness. First, according to the principle of stationary potential energy, the partial differential control formulae of the FG beams subjected to a distributed lateral force are derived. To obtain numerical results of the nonlinear bending, non-dimensional boundary conditions and control formulae are dispersed by applying the DQM. To verify the present solution, several examples are analyzed for nonlinear bending of homogeneous beams with various edges. A minute parametric research is in progress about the effect of the law index, transverse shear deformation, distributed lateral force and boundary conditions.

  2. High Energy Beam Impacts on Beam Intercepting Devices: Advanced Numerical Methods and Experimental Set-Up

    CERN Document Server

    Bertarelli, A; Carra, F; Cerutti, F; Dallocchio, A; Mariani, N; Timmins, M; Peroni, L; Scapin, M

    2011-01-01

    Beam Intercepting Devices are potentially exposed to severe accidental events triggered by direct impacts of energetic particle beams. State-of-the-art numerical methods are required to simulate the behaviour of affected components. A review of the different dynamic response regimes is presented, along with an indication of the most suited tools to treat each of them. The consequences on LHC tungsten collimators of a number of beam abort scenarios were extensively studied, resorting to a novel category of numerical explicit methods, named Hydrocodes. Full shower simulations were performed providing the energy deposition distribution. Structural dynamics and shock wave propagation analyses were carried out with varying beam parameters, identifying important thresholds for collimator operation, ranging from the onset of permanent damage up to catastrophic failure. Since the main limitation of these tools lies in the limited information available on constitutive material models under extreme conditions, a dedica...

  3. High Energy Beam Impacts on Beam Intercepting Devices: Advanced Numerical Methods and Experimental Set-up

    CERN Document Server

    Bertarelli, A; Carra, F; Cerutti, F; Dallocchio, A; Mariani, N; Timmins, M; Peroni, L; Scapin, M

    2011-01-01

    Beam Intercepting Devices are potentially exposed to severe accidental events triggered by direct impacts of energetic particle beams. State-of-the-art numerical methods are required to simulate the behaviour of affected components. A review of the different dynamic response regimes is presented, along with an indication of the most suited tools to treat each of them. The consequences on LHC tungsten collimators of a number of beam abort scenarios were extensively studied, resorting to a novel category of numerical explicit methods, named Hydrocodes. Full shower simulations were performed providing the energy deposition distribution. Structural dynamics and shock wave propagation analyses were carried out with varying beam parameters, identifying important thresholds for collimator operation, ranging from the onset of permanent damage up to catastrophic failure. Since the main limitation of these tools lies in the limited information available on constitutive material models under extreme conditions, a dedica...

  4. New method of beam bunching in free-ion lasers

    Energy Technology Data Exchange (ETDEWEB)

    Bessonov, E.G. [Lebedev Physics Institute, Moscow (Russian Federation)

    1995-12-31

    An effective ion beam bunching method is suggested. This method is based on a selective interaction of line spectrum laser light (e.g. axial mode structure light) with non-fully stripped ion beam cooled in a storage rings, arranging the ion beam in layers in radial direction of an energy-longitudinal coordinate plane and following rotation of the beam at the right angle after switching on the RF cavity or undulator grouper/buncher. Laser cooling of the ion beam can be used at this position after switching off the resonator to decrease the energy spread caused by accelerating field of the resonator. A relativistic multilayer ion mirror will be produced this way. Both monochromatic laser beams and intermediate monochromaticity and bandwidth light sources of spontaneous incoherent radiation can be used for production of hard and high power electromagnetic radiation by reflection from this mirror. The reflectivity of the mirror is rather high because of the cross-section of the backward Rayleigh scattering of photon light by non-fully stripped relativistic ions ({approximately}{lambda}{sup 2}) is much greater ({approximately} 10{divided_by}15 orders) then Thompson one ({approximately} r{sub e}{sup 2}). This position is valid even in the case of non-monochromatic laser light ({Delta}{omega}/{omega} {approximately} 10{sup -4}). Ion cooling both in longitudinal plane and three-dimensional radiation ion cooling had been proposed based on this observation. The using of these cooling techniques will permit to store high current and low emittance relativistic ion beams in storage rings. The bunched ion beam can be used in ordinary Free-Ion Lasers as well. After bunching the ion beam can be extracted from the storage ring in this case. Storage rings with zero momentum compaction function will permit to keep bunching of the ion beam for a long time.

  5. A method for hardening or curing adhesives for flocking thermally sensitive substrata by means of an electron-beam

    International Nuclear Information System (INIS)

    Nablo, S.V.; Fussa, A.D.

    1975-01-01

    The invention relates to a method for hardening or curing adhesives for flocking thermally sensitive substrata by means of an electron-beam. That method consists in accurately adjusting the parameters of irradiation by an electron-beam and the beam velocity so as to obtain, a very rapid hardening of adhesives used for fixing flocking materials, or the like, to thermally sensitive substrate. That can be applied to hardening or curing adhesives for flocking thermally-sensitive substrata which normally restrict the hardening rate [fr

  6. Advances in complexity of beam halo-chaos and its control methods for beam transport networks

    International Nuclear Information System (INIS)

    Fang Jinqing

    2004-11-01

    The complexity theory of beam halo-chaos in beam transport networks and its control methods for a new subject of high-tech field is discussed. It is pointed that in recent years, there has been growing interest in proton beams of high power linear accelerator due to its attractive features in possible breakthrough applications in national defense and industry. In particular, high-current accelerator driven clean activity nuclear power systems for various applications as energy resources has been one of the most focusing issues in the current research, because it provides a safer, cleaner and cheaper nuclear energy resource. However, halo-chaos in high-current beam transport networks become a key concerned issue because it can generate excessive radioactivity therefore significantly limits its applications. It is very important to study the complexity properties of beam halo-chaos and to understand the basic physical mechanisms for halo chaos formation as well as to develop effective control methods for its suppression. These are very challenging subjects for the current research. The main research advances in the subjects, including experimental investigation and the oretical research, especially some very efficient control methods developed through many years of efforts of authors are reviewed and summarized. Finally, some research outlooks are given. (author)

  7. A SIMPLE METHOD FOR MEASURING THE ELECTRON-BEAM MAGNETIZATION

    Energy Technology Data Exchange (ETDEWEB)

    Halavanau, A. [Fermilab; Qiang, G. [Tsinghua U., Beijing, Dept. Eng. Phys.; Wisniewski, E. [Argonne; Ha, G. [POSTECH, Pohang; Power, J. [Argonne; Piot, P. [Fermilab

    2016-10-18

    There are a number of projects that require magnetized beams, such as electron cooling or aiding in “flat” beam transforms. Here we explore a simple technique to characterize the magnetization, observed through the angular momentum of magnetized beams. These beams are produced through photoemission. The generating drive laser first passes through microlens arrays (fly-eye light condensers) to form a transversely modulated pulse incident on the photocathode surface [1]. The resulting charge distribution is then accelerated from the photocathode. We explore the evolution of the pattern via the relative shearing of the beamlets, providing information about the angular momentum. This method is illustrated through numerical simulations and preliminary measurements carried out at the Argonne Wakefield Accelerator (AWA) facility are presented.

  8. Kinematic adjustments during succesful and unsuccessful wolf jumps on the balance beam

    OpenAIRE

    Mauz, Danica; Jensen, Randall; Naundorf, Falk; Richter, Chris; Vieten, Manfred

    2013-01-01

    The current study examined differences in the kinematics between successful and failed landings of a wolf jump on the balance beam. Subjects were 35 elite level gymnasts performing in competition. Discrete point analysis and Analysis of Characterizing Phases found that failed landings involved higher initial longitudinal component of the inertia tensor, body angle in the anterior-posterior direction at takeoff and landing, and the medial-lateral component of angular velocity during the descen...

  9. Calibration method of parallel projection beams for 3D profile measurement

    Science.gov (United States)

    Lee, Shuo-Jen; Fan, Tienjung

    1996-10-01

    3D profile measurement of work-piece by non-contact optical methods has been studied extensively because of its importance in the automated manufacturing processes and quality control of components. In this paper, a projection method and its calibration algorithm of parallel projection means for 3D profile measurement system was presented. The proposed method used the pin-hole theory. An arc light which was assumed to be a point light source was positioned in the focal point of a parabolic mirror. After it was reflected by the parabolic mirror, uniform parallel light beams were projected. Using alignment collimator and telescope, the best positions of all of the optical elements in the system can be adjusted. Parameters of CCD lens, image center, arc light source and their relative positional relationship were also calibrated. This ensures the overall accuracy of the projection system. For most of the structured light optical methods, the size and shape of the dot laser beam or the length and width of a line laser beam of the projected slits were functions of the measurement range. A lot of efforts and caution have been conducted int he calibration process and mathematical manipulations are required to assure the measurement accuracy. The proposed parallel projection beam method eliminates above mentioned difficulty. It could be a robust and efficient non-contact optical method for the measurement of 3D profile.

  10. The improved design method of shear strength of reinforced concrete beams without transverse reinforcement

    Directory of Open Access Journals (Sweden)

    Vegera Pavlo

    2017-12-01

    Full Text Available In this article, results of experimental testing of reinforced concrete beams without transverse shear reinforcement are given. Three prototypes for improved testing methods were tested. The testing variable parameter was the shear span to the effective depth ratio. In the result of the tests we noticed that bearing capacity of RC beams is increased with the decreasing shear span to the effective depth ratio. The design method according to current codes was applied to test samples and it showed a significant discrepancy results. Than we proposed the improved design method using the adjusted value of shear strength of concrete CRd,c. The results obtained by the improved design method showed satisfactory reproducibility.

  11. Modern map methods in particle beam physics

    CERN Document Server

    Berz, Martin

    1999-01-01

    Advances in Imaging & Electron Physics merges two long-running serials--Advances in Electronics & Electron Physics and Advances in Optical & Electron Microscopy. The series features extended articles on the physics of electron devices (especially semiconductor devices), particle optics at high and low energies, microlithography, image science and digital image processing, electromagnetic wave propagation, electron microscopy, and the computing methods used in all these domains.

  12. A Comparison of Methods of Least Squares Adjustment of Traverses.

    Science.gov (United States)

    1984-12-01

    Experience course in October 1983. All of the known station positions and azimuths (Table II) were adjusted by the Coast and Geodetic Survey by third...MM*0. >S N0 MxZ 10%. . ...- N-0- N I >-- 0-Z0 00 Z-M >- 0 0N 0t - <<> 0’ 4 0 0r\\ - N- -> 10-- 1 1 co -- 1 11 Clif - fill X: N 0x C. 0 * 0 > -X o *>Xy... Coast and Geodetic Survey Horizontal Control Data uad 361214, Stations 1037, U5U-B70g1, -NEU-TU6 -70, 6 3. 7. Mikhail, Edward M., and Gracie, Gordon

  13. Design of a low-temperature plasma (LTP) probe with adjustable output temperature and variable beam diameter for the direct detection of organic molecules.

    Science.gov (United States)

    Martínez-Jarquín, Sandra; Winkler, Robert

    2013-03-15

    The direct detection of organic molecules by mass spectrometry requires ionization methods which are compatible with ambient conditions. A relatively new strategy is the use of a free low-temperature plasma beam for ionization. The objective is to design a safe and adjustable plasma beam to enable optimal ionization and desorption parameters for specific molecules. A plasma probe based on a dielectric barrier discharge was designed, where the plasma is guided through an internal second tube. This setup permits different beam diameter settings and the control of the plasma temperature. The ionization and desorption of pure organic compounds, as well as their direct detection from roasted coffee beans, were tested. The presented plasma probe provides improved safety with respect to arcing, ozone generation and electric shock, compared with conventional designs. The functionality of previously reported devices is expanded. A defined plasma diameter can be set by choosing the appropriate insert, while the input voltage controls the plasma temperature. The variation of measurement parameters enables the optimized direct detection of target compounds from roasted coffee beans, such as caffeine, guaiacol and vanillin. The presented low-temperature plasma probe allows the fine-tuning of ionization and desorption parameters, according to the target molecules. Possible applications include: (1) The ambient ionization and desorption of organic compounds with different volatility and (2) The direct analysis of food products such as roasted coffee beans. Copyright © 2013 John Wiley & Sons, Ltd.

  14. Energy resolution methods efficiency depending on beam source ...

    Indian Academy of Sciences (India)

    2015-11-27

    Nov 27, 2015 ... Home; Journals; Pramana – Journal of Physics; Volume 69; Issue 3. Energy resolution methods efficiency depending on beam source position of potassium clusters in time-of-flight mass spectrometer. Ş Şentürk F Demiray O Özsoy. Research Articles Volume 69 Issue 3 September 2007 pp 459-465 ...

  15. New Combined Electron-Beam Methods of Wastewater Purification

    International Nuclear Information System (INIS)

    Pikaev, A.K.; Makarov, I.E.; Ponomarev, A.V.; Kartasheva, L.I.; Podzorova, E.A.; Chulkov, V.N.; Han, B.; Kim, D.K.

    1999-01-01

    The paper is a brief review of the results obtained with the participation of the authors from the study on combined electron-beam methods for purification of some wastewaters. The data on purification of wastewaters containing dyes or hydrogen peroxide and municipal wastewater in the aerosol flow are considered

  16. Method and apparatus to monitor a beam of ionizing radiation

    Science.gov (United States)

    Blackburn, Brandon W.; Chichester, David L.; Watson, Scott M.; Johnson, James T.; Kinlaw, Mathew T.

    2015-06-02

    Methods and apparatus to capture images of fluorescence generated by ionizing radiation and determine a position of a beam of ionizing radiation generating the fluorescence from the captured images. In one embodiment, the fluorescence is the result of ionization and recombination of nitrogen in air.

  17. Melting and purification methods in electron beam furnaces. Pt. 1

    International Nuclear Information System (INIS)

    Stephan, H.

    1975-01-01

    After a general review on the market of electron beam furnaces, the melting methods and their variations are discussed in detail. The purification effects shown in a table allow a view on the main application. The losses of volatile alloy elements and the chances of compensation are specially discussed. (orig.) [de

  18. Optimum adjusting method of fuel in a reactor

    International Nuclear Information System (INIS)

    Otsuji, Niro; Shirakawa, Toshihisa; Toyoshi, Isamu; Tatemichi, Shin-ichiro; Mukai, Hideyuki.

    1976-01-01

    Object: To effectively select an intermediate pattern of a control rod to thereby shorten time required to adjust the fuel. Structure: Control rods are divided into several regions in concentric and circular fashion or the like within a core. A control rod position satisfied with a thermal limit value in a maximal power level is preset as a target position by a three dimensional nuclear hydrothermal force counting code or the like. Next, an intermediate pattern of the control rods in each region is determined on the basis of the target position, and while judging operational condition, a part of fuel rods is maintained for a given period of time in a level more than power density of the target position with the power increased within the range not to produce interaction between pellet and cladding material (PCI), so that said power density may be learned. Thereafter, the power is rapidly decreased. Similar operation may be applied to the other fuel rods, after which the control rod may be set the target position to obtain the maximum power level. (Ikeda, J.)

  19. A practical attenuation compensation method for cone beam spect

    International Nuclear Information System (INIS)

    Manglos, S.H.; Jaszczak, R.J.; Floyd, C.E.; Greer, K.L.; Coleman, R.E.

    1987-01-01

    An algorithm for attenuation compensation of cone beam SPECT images has been developed and implemented. The algorithm is based on a multiplicative post-processing method previously used for parallel and fan beam geometries. This method computes the compensation from the estimated average attenuation of photons originating from each image pixel. In the present development, a uniform attenuation coefficient inside of the body contour is assumed, although the method could be extended to include a non-uniform attenuation map. The algorithm is tested with experimental projections of a phantom obtained using a cone beam collimator. Profiles through the reconstructed images are presented as a quantitative test of the improvement due to the compensation. The algorithm provides adequate compensation for attenuation in a simple uniform cylindrical phantom, and the computational time is short compared to that expected for iterative reconstruction techniques. Also observed are image distortions in some reconstructed slices when the source distribution extends beyond the edge of the cone beam axial field-of-view

  20. 48 CFR 52.222-31 - Davis-Bacon Act-Price Adjustment (Percentage Method).

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 2 2010-10-01 2010-10-01 false Davis-Bacon Act-Price... Provisions and Clauses 52.222-31 Davis-Bacon Act—Price Adjustment (Percentage Method). As prescribed in 22.407(f), insert the following clause: Davis-Bacon Act—Price Adjustment (Percentage Method) (DEC 2001...

  1. An Illustration to Assist in Comparing and Remembering Several Multiplicity Adjustment Methods

    Science.gov (United States)

    Hasler, Mario

    2017-01-01

    There are many well-known or new methods to adjust statistical tests for multiplicity. This article provides an illustration helping lecturers or consultants to remember the differences of three important multiplicity adjustment methods and to explain them to non-statisticians.

  2. Geometry calibration method for a cone-beam CT system.

    Science.gov (United States)

    Yang, Hongkai; Kang, Kejun; Xing, Yuxiang

    2017-05-01

    The positioning accuracy of each component is important to ensure the image quality of cone-beam CT. However, accurate positioning is not easy and requires experience and time. The option is to calibrate the geometric parameters and then plug them into a reconstruction algorithm which is the preferred solution in practice. In this case, the image quality is determined by the accuracy and precision of the calibration method. This work describes a method to independently calibrate an imaging system in each pose (projection angle) for a cone-beam CT with a nonideal circular trajectory. The calibration method uses a phantom with 12 beads on 2 planes that are observed on the radiographic images. This pose-independent calibration method (PIC) can decorrelate the relationships among the geometric parameters so that the parameters can be estimated one-by-one. This simplifies the calibration process. Besides the pose-independent calibration method, this paper also describes an extended calibration method with additional constraints on the system geometry. Both methods are validated with numerical simulations and then experimentally on a practical system with a scanning object loosely supported by rotating wheels. The object rotates during the CT data acquisition. The angular and pose information of the CT system are not accurately known a priori in this case. The numerical simulations and the experiments both provide satisfactory results. The relative error of the calibrated source-to-detector distance in the simulation is less than 0.1%. The errors in the calibrated roll, pitch, and yaw angles are less than 0.04°. A sensitivity study using various bead position uncertainties in random directions shows that the pose-independent calibration method is robust to measurement errors. Tests were also done with a nonideal circular trajectory for further validation. Images reconstructed using the geometric parameters from both the pose-independent and the extended calibration

  3. Optimization method for electron beam melting and refining of metals

    Science.gov (United States)

    Donchev, Veliko; Vutova, Katia

    2014-03-01

    Pure metals and special alloys obtained by electron beam melting and refining (EBMR) in vacuum, using electron beams as a heating source, have a lot of applications in nuclear and airspace industries, electronics, medicine, etc. An analytical optimization problem for the EBMR process based on mathematical heat model is proposed. The used criterion is integral functional minimization of a partial derivative of the temperature in the metal sample. The investigated technological parameters are the electron beam power, beam radius, the metal casting velocity, etc. The optimization problem is discretized using a non-stationary heat model and corresponding adapted Pismen-Rekford numerical scheme, developed by us and multidimensional trapezional rule. Thus a discrete optimization problem is built where the criterion is a function of technological process parameters. The discrete optimization problem is heuristically solved by cluster optimization method. Corresponding software for the optimization task is developed. The proposed optimization scheme can be applied for quality improvement of the pure metals (Ta, Ti, Cu, etc.) produced by the modern and ecological-friendly EBMR process.

  4. A general exact method for synthesizing parallel-beam projections from cone-beam projections via filtered backprojection

    International Nuclear Information System (INIS)

    Li Liang; Chen Zhiqiang; Xing Yuxiang; Zhang Li; Kang Kejun; Wang Ge

    2006-01-01

    In recent years, image reconstruction methods for cone-beam computed tomography (CT) have been extensively studied. However, few of these studies discussed computing parallel-beam projections from cone-beam projections. In this paper, we focus on the exact synthesis of complete or incomplete parallel-beam projections from cone-beam projections. First, an extended central slice theorem is described to establish a relationship between the Radon space and the Fourier space. Then, data sufficiency conditions are proposed for computing parallel-beam projection data from cone-beam data. Using these results, a general filtered backprojection algorithm is formulated that can exactly synthesize parallel-beam projection data from cone-beam projection data. As an example, we prove that parallel-beam projections can be exactly synthesized in an angular range in the case of circular cone-beam scanning. Interestingly, this angular range is larger than that derived in the Feldkamp reconstruction framework. Numerical experiments are performed in the circular scanning case to verify our method

  5. Method and apparatus for laser-controlled proton beam radiology

    Science.gov (United States)

    Johnstone, Carol J.

    1998-01-01

    A proton beam radiology system provides cancer treatment and proton radiography. The system includes an accelerator for producing an H.sup.- beam and a laser source for generating a laser beam. A photodetachment module is located proximate the periphery of the accelerator. The photodetachment module combines the H.sup.- beam and laser beam to produce a neutral beam therefrom within a subsection of the H.sup.- beam. The photodetachment module emits the neutral beam along a trajectory defined by the laser beam. The photodetachment module includes a stripping foil which forms a proton beam from the neutral beam. The proton beam is delivered to a conveyance segment which transports the proton beam to a patient treatment station. The photodetachment module further includes a laser scanner which moves the laser beam along a path transverse to the cross-section of the H.sup.- beam in order to form the neutral beam in subsections of the H.sup.- beam. As the scanning laser moves across the H.sup.- beam, it similarly varies the trajectory of the proton beam emitted from the photodetachment module and in turn varies the target location of the proton beam upon the patient. Intensity modulation of the proton beam can also be achieved by controlling the output of the laser.

  6. Method to render second order beam optics programs symplectic

    International Nuclear Information System (INIS)

    Douglas, D.; Servranckx, R.V.

    1984-10-01

    We present evidence that second order matrix-based beam optics programs violate the symplectic condition. A simple method to avoid this difficulty, based on a generating function approach to evaluating transfer maps, is described. A simple example illustrating the non-symplectricity of second order matrix methods, and the effectiveness of our solution to the problem, is provided. We conclude that it is in fact possible to bring second order matrix optics methods to a canonical form. The procedure for doing so has been implemented in the program DIMAT, and could be implemented in programs such as TRANSPORT and TURTLE, making them useful in multiturn applications. 15 refs

  7. Adjustable mounting device for high-volume production of beam-shaping systems for high-power diode lasers

    Science.gov (United States)

    Haag, Sebastian; Bernhardt, Henning; Rübenach, Olaf; Haverkamp, Tobias; Müller, Tobias; Zontar, Daniel; Brecher, Christian

    2015-02-01

    In many applications for high-power diode lasers, the production of beam-shaping and homogenizing optical systems experience rising volumes and dynamical market demands. The automation of assembly processes on flexible and reconfigurable machines can contribute to a more responsive and scalable production. The paper presents a flexible mounting device designed for the challenging assembly of side-tab based optical systems. It provides design elements for precisely referencing and fixating two optical elements in a well-defined geometric relation. Side tabs are presented to the machine allowing the application of glue and a rotating mechanism allows the attachment to the optical elements. The device can be adjusted to fit different form factors and it can be used in high-volume assembly machines. The paper shows the utilization of the device for a collimation module consisting of a fast-axis and a slow-axis collimation lens. Results regarding the repeatability and process capability of bonding side tab assemblies as well as estimates from 3D simulation for overall performance indicators achieved such as cycle time and throughput will be discussed.

  8. Material-Point Method Analysis of Bending in Elastic Beams

    DEFF Research Database (Denmark)

    Andersen, Søren Mikkel; Andersen, Lars

    2007-01-01

    The aim of this paper is to test different types of spatial interpolation for the material-point method. The interpolations include quadratic elements and cubic splines. A brief introduction to the material-point method is given. Simple liner-elastic problems are tested, including the classical...... cantilevered beam problem. As shown in the paper, the use of negative shape functions is not consistent with the material-point method in its current form, necessitating other types of interpolation such as cubic splines in order to obtain smoother representations of field quantities. It is shown...... that the smoother field representation using the cubic splines yields a physically more realistic behaviour for impact problems than the traditional linear interpolation....

  9. Material-point Method Analysis of Bending in Elastic Beams

    DEFF Research Database (Denmark)

    Andersen, Søren Mikkel; Andersen, Lars

    The aim of this paper is to test different types of spatial interpolation for the materialpoint method. The interpolations include quadratic elements and cubic splines. A brief introduction to the material-point method is given. Simple liner-elastic problems are tested, including the classical...... cantilevered beam problem. As shown in the paper, the use of negative shape functions is not consistent with the material-point method in its current form, necessitating other types of interpolation such as cubic splines in order to obtain smoother representations of field quantities. It is shown...... that the smoother field representation using the cubic splines yields a physically more realistic behaviour for impact problems than the traditional linear interpolation....

  10. A numerical method for free vibration analysis of beams

    Directory of Open Access Journals (Sweden)

    A. Prokić

    Full Text Available In this paper, a numerical method for solution of the free vibration of beams governed by a set of second-order ordinary differential equations of variable coefficients, with arbitrary boundary conditions, is presented. The method is based on numerical integration rather than the numerical differentiation since the highest derivatives of governing functions are chosen as the basic unknown quantities. The kernelsof integral equations turn out to be Green's function of corresponding equation with homogeneous boundary conditions. The accuracy of the proposed method is demonstrated by comparing the calculated results with those available in the literature. It is shown that good accuracy can be obtained even with a relatively small number of nodes.

  11. Analysis of concrete beams using applied element method

    Science.gov (United States)

    Lincy Christy, D.; Madhavan Pillai, T. M.; Nagarajan, Praveen

    2018-03-01

    The Applied Element Method (AEM) is a displacement based method of structural analysis. Some of its features are similar to that of Finite Element Method (FEM). In AEM, the structure is analysed by dividing it into several elements similar to FEM. But, in AEM, elements are connected by springs instead of nodes as in the case of FEM. In this paper, background to AEM is discussed and necessary equations are derived. For illustrating the application of AEM, it has been used to analyse plain concrete beam of fixed support condition. The analysis is limited to the analysis of 2-dimensional structures. It was found that the number of springs has no much influence on the results. AEM could predict deflection and reactions with reasonable degree of accuracy.

  12. An effective method for trapping ion beams in superfluid helium for laser spectroscopy experiments

    Directory of Open Access Journals (Sweden)

    Yang X.F

    2014-03-01

    Full Text Available A novel laser spectroscopy technique -“OROCHI” (Optical Radioisotopes Observation in Condensed Helium as Ion-catcher has been proposed. This method aimed to investigate the structure of exotic nuclei systematically by measuring nuclear spins and moments. For in-situ laser spectroscopy of atoms in He II, a method to trap atoms precisely at the observation region of laser is highly needed. In this work, a setup composed of a degrader, two plastic scintillators and a photon detection system is further tested and verified for adjusting and checking the stopping position of 84–87Rb beam. Details of the current setup, experimental results using this method are presented.

  13. Active Beam Shaping System and Method Using Sequential Deformable Mirrors

    Science.gov (United States)

    Norman, Colin A. (Inventor); Pueyo, Laurent A. (Inventor)

    2015-01-01

    An active optical beam shaping system includes a first deformable mirror arranged to at least partially intercept an entrance beam of light and to provide a first reflected beam of light, a second deformable mirror arranged to at least partially intercept the first reflected beam of light from the first deformable mirror and to provide a second reflected beam of light, and a signal processing and control system configured to communicate with the first and second deformable mirrors. The first deformable mirror, the second deformable mirror and the signal processing and control system together provide a large amplitude light modulation range to provide an actively shaped optical beam.

  14. Numerical solution method of nonlinear guided modes with a finite difference complex axis beam propagation method

    NARCIS (Netherlands)

    Wijnands, F.H.G.M.; Wijnands, Frank; Hoekstra, Hugo; Krijnen, Gijsbertus J.M.; de Ridder, R.M.

    A method to construct modal fields for an arbitrary one- or two-dimensional intensity dependent refractive index structure is described. An arbitrary starting field is propagated along an imaginary axis using the Finite Difference Beam Propagation Method (FDBPM) based upon the Slowly Varying

  15. A method of beam control for NFZ-10 industrial irradiation linac

    International Nuclear Information System (INIS)

    Zhao Minghua

    2000-01-01

    Traditionally negative feedback coming from output beam is used to stabilize output beam by regulating filament voltage of bombarding diode electron gun. The authors analysed the shortcomings of the method in detail and put forward a new method of regulating bombarding high voltage in NFZ-10 industrial irradiation linac. Output beam with high stability and high accuracy was obtained

  16. Underwater Environment SDAP Method Using Multi Single-Beam Sonars

    Directory of Open Access Journals (Sweden)

    Zheping Yan

    2013-01-01

    Full Text Available A new autopilot system for unmanned underwater vehicle (UUV using multi-single-beam sonars is proposed for environmental exploration. The proposed autopilot system is known as simultaneous detection and patrolling (SDAP, which addresses two fundamental challenges: autonomous guidance and control. Autonomous guidance, autonomous path planning, and target tracking are based on the desired reference path which is reconstructed from the sonar data collected from the environmental contour with the predefined safety distance. The reference path is first estimated by using a support vector clustering inertia method and then refined by Bézier curves in order to satisfy the inertia property of the UUV. Differential geometry feedback linearization method is used to guide the vehicle entering into the predefined path while finite predictive stable inversion control algorithm is employed for autonomous target approaching. The experimental results from sea trials have demonstrated that the proposed system can provide satisfactory performance implying its great potential for future underwater exploration tasks.

  17. Early Parental Positive Behavior Support and Childhood Adjustment: Addressing Enduring Questions with New Methods

    OpenAIRE

    Waller, Rebecca; Gardner, Frances; Dishion, Thomas; Sitnick, Stephanie L.; Shaw, Daniel S.; Winter, Charlotte E.; Wilson, Melvin

    2014-01-01

    A large literature provides strong empirical support for the influence of parenting on child outcomes. The current study addresses enduring research questions testing the importance of early parenting behavior to children’s adjustment. Specifically, we developed and tested a novel multi-method observational measure of parental positive behavior support at age 2. Next, we tested whether early parental positive behavior support was related to child adjustment at school age, within a multi-agent...

  18. SU-E-J-126: An Online Replanning Method for FFF Beams Without Couch Shift

    Energy Technology Data Exchange (ETDEWEB)

    Ahunbay, E; Ates, O; Li, X [Medical College of Wisconsin, Milwaukee, WI (United States)

    2015-06-15

    Purpose: In a situation that couch shift for patient positioning is not preferred or prohibited (e.g., MR-Linac), segment aperture morphing (SAM) can address target dislocation and deformation. For IMRT/VMAT with flattening filter free (FFF) beams, however, SAM method would lead to an adverse translational dose effect due to the beam unflattening. Here we propose a new 2-step process to address both the translational effect of FFF beams and the target deformation. Methods: The replanning method consists of an offline and an online steps. The offline step is to create a series of pre-shifted plans (PSP) obtained by a so called “warm start” optimization (starting optimization from the original plan, rather from scratch) at a series of isocenter shifts with fixed distance (e.g. 2 cm, at x,y,z = 2,0,0 ; 2,2,0 ; 0,2,0; …;− 2,0,0). The PSPs all have the same number of segments with very similar shapes, since the warm-start optimization only adjusts the MLC positions instead of regenerating them. In the online step, a new plan is obtained by linearly interpolating the MLC positions and the monitor units of the closest PSPs for the shift determined from the image of the day. This two-step process is completely automated, and instantaneously fast (no optimization or dose calculation needed). The previously-developed SAM algorithm is then applied for daily deformation. We tested the method on sample prostate and pancreas cases. Results: The two-step interpolation method can account for the adverse dose effects from FFF beams, while SAM corrects for the target deformation. The whole process takes the same time as the previously reported SAM process (5–10 min). Conclusion: The new two-step method plus SAM can address both the translation effects of FFF beams and target deformation, and can be executed in full automation requiring no additional time from the SAM process. This research was supported by Elekta inc. (Crawley, UK)

  19. A new method for beam stacking in storage rings

    Energy Technology Data Exchange (ETDEWEB)

    Bhat, C.M.; /Fermilab

    2008-06-01

    Recently, I developed a new beam stacking scheme for synchrotron storage rings called 'longitudinal phase-space coating' (LPSC). This scheme has been convincingly validated by multi-particle beam dynamics simulations and has been demonstrated with beam experiments at the Fermilab Recycler. Here, I present the results from both simulations and experiments. The beam stacking scheme presented here is the first of its kind.

  20. A New Scale Factor Adjustment Method for Magnetic Force Feedback Accelerometer

    Directory of Open Access Journals (Sweden)

    Xiangqing Huang

    2017-10-01

    Full Text Available A new and simple method to adjust the scale factor of a magnetic force feedback accelerometer is presented, which could be used in developing a rotating accelerometer gravity gradient instrument (GGI. Adjusting and matching the acceleration-to-current transfer function of the four accelerometers automatically is one of the basic and necessary technologies for rejecting the common mode accelerations in the development of GGI. In order to adjust the scale factor of the magnetic force rebalance accelerometer, an external current is injected and combined with the normal feedback current; they are then applied together to the torque coil of the magnetic actuator. The injected current could be varied proportionally according to the external adjustment needs, and the change in the acceleration-to-current transfer function then realized dynamically. The new adjustment method has the advantages of no extra assembly and ease of operation. Changes in the scale factors range from 33% smaller to 100% larger are verified experimentally by adjusting the different external coefficients. The static noise of the used accelerometer is compared under conditions with and without the injecting current, and the experimental results find no change at the current noise level, which further confirms the validity of the presented method.

  1. Self-adjusting grid methods for one-dimensional hyperbolic conservation laws

    Science.gov (United States)

    Harten, A.; Hyman, J. M.

    1983-01-01

    The automatic adjustment of a grid which follows the dynamics of the numerical solution of hyperbolic conservation laws is given. The grid motion is determined by averaging the local characteristic velocities of the equations with respect to the amplitudes of the signals. The resulting algorithm is a simple extension of many currently popular Godunov-type methods. Computer codes using one of these methods can be easily modified to add the moving mesh as an option. Numerical examples are given that illustrate the improved accuracy of Godunov's and Roe's methods on a self-adjusting mesh. Previously announced in STAR as N83-15008

  2. A method to adjust radiation dose-response relationships for clinical risk factors

    DEFF Research Database (Denmark)

    Appelt, Ane Lindegaard; Vogelius, Ivan R

    2012-01-01

    Several clinical risk factors for radiation induced toxicity have been identified in the literature. Here, we present a method to quantify the effect of clinical risk factors on radiation dose-response curves and apply the method to adjust the dose-response for radiation pneumonitis for patients...

  3. Adjustable collimator

    International Nuclear Information System (INIS)

    Carlson, R.W.; Covic, J.; Leininger, G.

    1981-01-01

    In a rotating fan beam tomographic scanner there is included an adjustable collimator and shutter assembly. The assembly includes a fan angle collimation cylinder having a plurality of different length slots through which the beam may pass for adjusting the fan angle of the beam. It also includes a beam thickness cylinder having a plurality of slots of different widths for adjusting the thickness of the beam. Further, some of the slots have filter materials mounted therein so that the operator may select from a plurality of filters. Also disclosed is a servo motor system which allows the operator to select the desired fan angle, beam thickness and filter from a remote location. An additional feature is a failsafe shutter assembly which includes a spring biased shutter cylinder mounted in the collimation cylinders. The servo motor control circuit checks several system conditions before the shutter is rendered openable. Further, the circuit cuts off the radiation if the shutter fails to open or close properly. A still further feature is a reference radiation intensity monitor which includes a tuning-fork shaped light conducting element having a scintillation crystal mounted on each tine. The monitor is placed adjacent the collimator between it and the source with the pair of crystals to either side of the fan beam

  4. Uniform irradiation system using beam scanning method for cyclotron

    International Nuclear Information System (INIS)

    Agematsu, Takashi; Okumura, Susumu; Arakawa, Kazuo

    1994-03-01

    JAERI AVF-cyclotron is equipped with an ion beam scanner for large area irradiation. The two-dimensional fluence distribution of ion beam obtained using cellulose triacetate film dosimeter was not uniform. This is resulted from the distortion of excitation current for electromagnet of the scanner. So, the beam scanning condition, i.e., the relation between the ion species, the beam profile and the scanning width, was extremely limited to make a good uniformity. We have developed a beam scanning simulator to get fluence distributions by calculation and then compared the simulated distributions with the measured ones. It was revealed that the both of them are in good agreement and the beam scanning condition to get good uniformity was led by using this simulator. On the basis of these results, the power supply of scanner was improved. A good uniformity of beam distribution was available. (author)

  5. An adjustment method for active reflector of large high-frequency antennas considering gain and boresight

    Science.gov (United States)

    Wang, Cong-Si; Xiao, Lan; Wang, Wei; Xu, Qian; Xiang, Bin-Bin; Zhong, Jian-Feng; Jiang, Li; Bao, Hong; Wang, Na

    2017-04-01

    The design of the Qitai 110 m Radio Telescope (QTT) with large aperture and very high working frequency (115 GHz) was investigated in Xinjiang, China. The results lead to a main reflector with high surface precision and high pointing precision. In this paper, the properties of active surface adjustment in a deformed parabolic reflector antenna are analyzed. To assure the performance of large reflector antennas such as gain and boresight, which can be obtained by utilizing an electromechanical coupling model, and satisfy them simultaneously, research on active surface adjustment applied to a new parabolic reflector as target surface has been done. Based on the initial position of actuators and the relationship between adjustment points and target points, a novel mathematical model and a program that directly calculates the movements of actuators have been developed for guiding the active surface adjustment of large reflector antennas. This adjustment method is applied to an 8 m reflector antenna, in which we only consider gravity deformation. The results show that this method is more efficient in adjusting the surface and improving the working performance.

  6. The adaptive problems of female teenage refugees and their behavioral adjustment methods for coping

    Directory of Open Access Journals (Sweden)

    Mhaidat F

    2016-04-01

    Full Text Available Fatin Mhaidat Department of Educational Psychology, Faculty of Educational Sciences, The Hashemite University, Zarqa, Jordan Abstract: This study aimed at identifying the levels of adaptive problems among teenage female refugees in the government schools and explored the behavioral methods that were used to cope with the problems. The sample was composed of 220 Syrian female students (seventh to first secondary grades enrolled at government schools within the Zarqa Directorate and who came to Jordan due to the war conditions in their home country. The study used the scale of adaptive problems that consists of four dimensions (depression, anger and hostility, low self-esteem, and feeling insecure and a questionnaire of the behavioral adjustment methods for dealing with the problem of asylum. The results indicated that the Syrian teenage female refugees suffer a moderate degree of adaptation problems, and the positive adjustment methods they have used are more than the negatives. Keywords: adaptive problems, female teenage refugees, behavioral adjustment

  7. Modeling of Cracked Beams by the Experimental Design Method

    Directory of Open Access Journals (Sweden)

    M. Serier

    Full Text Available Abstract The understanding of phenomena, no matter their nature is based on the experimental results found. In the most cases, this requires an important number of tests in order to put a reliable and useful observation served into solving the technical problems subsequently. This paper is based on independent and variables combination resulting from experimentation in a mathematical formulation. Indeed, mathematical modeling gives us the advantage to optimize and predict the right choices without passing each case by the experiment. In this work we plan to apply the experimental design method on the experimental results found by (Deokar, A, 2011, concerning the effect of the size and position of a crack on the measured frequency of a beam console, and validating the mathematical model to predict other frequencies

  8. Experimental device for measurement of dielectronic recombination cross section of C3+: method of confluent beam method

    International Nuclear Information System (INIS)

    Menier, A.

    1985-09-01

    Description of an instrumental device allowing dielectronic recombination cross section measurement is presented. Recombination of C 3+ for high quantum number is studied. This device, using the confluent beam method, entailed the development of an electron gun producing weakly divergent beam. A detector of highly excited ion allowing a quick and accurate measurement of ion beam energy is described in detail. Beam-residual gas interaction mechanisms are studied and instrumental incertitudes are calculated [fr

  9. A novel method to survey parameters of an ion beam and its interaction with a target

    Science.gov (United States)

    Long, J. D.; Yang, Z.; Li, J.; Wang, X. H.; Wang, T.; Lan, C. H.; Dong, P.; Li, X.; He, J. L.; Zheng, L.; Liu, P.

    2017-09-01

    Beam profile and composition of the pulsed ion beam from a vacuum arc source are valuable information for designing a high-intensity deuterium-tritium neutron generator. Traditional methods are notoriously difficult to obtain the information at the same time. A novel off-line diagnostic method is presented, which can obtain the transverse beam profile with high resolution as well as species of the ions in the beam. The method is using a silicon target with high purity to interact with the ion beam, and then use secondary ion mass spectrometry (SIMS) to analyze the interaction zone of the target to get the beam information. More information on beam-target interaction could get simultaneously. Proof-of-principle simulation and experimental works have demonstrated this method is practical.

  10. Adjust the method of the FMEA to the requirements of the aviation industry

    Directory of Open Access Journals (Sweden)

    Andrzej FELLNER

    2015-12-01

    Full Text Available The article presents a summary of current methods used in aviation and rail transport. It also contains a proposal to adjust the method of the FMEA to the latest requirements of the airline industry. The authors suggested tables of indicators Zn, Pr and Dt necessary to implement FMEA method of risk analysis taking into account current achievements aerospace and rail safety. Also proposed acceptable limits of the RPN number which allows you to classify threats.

  11. Adjusted Empirical Likelihood Method in the Presence of Nuisance Parameters with Application to the Sharpe Ratio

    Directory of Open Access Journals (Sweden)

    Yuejiao Fu

    2018-04-01

    Full Text Available The Sharpe ratio is a widely used risk-adjusted performance measurement in economics and finance. Most of the known statistical inferential methods devoted to the Sharpe ratio are based on the assumption that the data are normally distributed. In this article, without making any distributional assumption on the data, we develop the adjusted empirical likelihood method to obtain inference for a parameter of interest in the presence of nuisance parameters. We show that the log adjusted empirical likelihood ratio statistic is asymptotically distributed as the chi-square distribution. The proposed method is applied to obtain inference for the Sharpe ratio. Simulation results illustrate that the proposed method is comparable to Jobson and Korkie’s method (1981 and outperforms the empirical likelihood method when the data are from a symmetric distribution. In addition, when the data are from a skewed distribution, the proposed method significantly outperforms all other existing methods. A real-data example is analyzed to exemplify the application of the proposed method.

  12. A comparison of methods to adjust for continuous covariates in the analysis of randomised trials

    Directory of Open Access Journals (Sweden)

    Brennan C. Kahan

    2016-04-01

    Full Text Available Abstract Background Although covariate adjustment in the analysis of randomised trials can be beneficial, adjustment for continuous covariates is complicated by the fact that the association between covariate and outcome must be specified. Misspecification of this association can lead to reduced power, and potentially incorrect conclusions regarding treatment efficacy. Methods We compared several methods of adjustment to determine which is best when the association between covariate and outcome is unknown. We assessed (a dichotomisation or categorisation; (b assuming a linear association with outcome; (c using fractional polynomials with one (FP1 or two (FP2 polynomial terms; and (d using restricted cubic splines with 3 or 5 knots. We evaluated each method using simulation and through a re-analysis of trial datasets. Results Methods which kept covariates as continuous typically had higher power than methods which used categorisation. Dichotomisation, categorisation, and assuming a linear association all led to large reductions in power when the true association was non-linear. FP2 models and restricted cubic splines with 3 or 5 knots performed best overall. Conclusions For the analysis of randomised trials we recommend (1 adjusting for continuous covariates even if their association with outcome is unknown; (2 keeping covariates as continuous; and (3 using fractional polynomials with two polynomial terms or restricted cubic splines with 3 to 5 knots when a linear association is in doubt.

  13. An online replanning method using warm start optimization and aperture morphing for flattening-filter-free beams.

    Science.gov (United States)

    Ahunbay, Ergun E; Ates, O; Li, X A

    2016-08-01

    In a situation where a couch shift for patient positioning is not preferred or prohibited (e.g., MR-linac), segment aperture morphing (SAM) can address target dislocation and deformation. For IMRT/VMAT with flattening-filter-free (FFF) beams, however, SAM method would lead to an adverse translational dose effect due to the beam unflattening. Here the authors propose a new two-step process to address both the translational effect of FFF beams and the target deformation. The replanning method consists of an offline and an online step. The offline step is to create a series of preshifted-plans (PSPs) obtained by a so-called "warm start" optimization (starting optimization from the original plan, rather than from scratch) at a series of isocenter shifts. The PSPs all have the same number of segments with very similar shapes, since the warm start optimization only adjusts the MLC positions instead of regenerating them. In the online step, a new plan is obtained by picking the closest PSP or linearly interpolating the MLC positions and the monitor units of the closest PSPs for the shift determined from the image of the day. This two-step process is completely automated and almost instantaneous (no optimization or dose calculation needed). The previously developed SAM algorithm is then applied for daily deformation. The authors tested the method on sample prostate and pancreas cases. The two-step interpolation method can account for the adverse dose effects from FFF beams, while SAM corrects for the target deformation. Plan interpolation method is effective in diminishing the unflat beam effect and may allow reducing the required number of PSPs. The whole process takes the same time as the previously reported SAM process (5-10 min). The new two-step method plus SAM can address both the translation effects of FFF beams and target deformation, and can be executed in full automation except the delineation of target contour required by the SAM process.

  14. Simultaneous determination of electron beam profile and material response using self-consistent iterative method

    Science.gov (United States)

    Kandel, Yudhishthir; Denbeaux, Gregory

    2016-08-01

    We develop a novel iterative method to accurately measure electron beam shape (current density distribution) and monotonic material response as a function of position. A common method is to scan an electron beam across a knife edge along many angles to give an approximate measure of the beam profile, however such scans are not easy to obtain in all systems. The present work uses only an electron beam and multiple exposed regions of a thin film of photoresist to measure the complete beam profile for any beam shape, where the material response is characterized externally. This simplifies the setup of new experimental tools. We solve for self-consistent photoresist thickness loss response to dose and the electron beam profile simultaneously by optimizing a novel functional iteratively. We also show the successful implementation of the method in a real world data set corrupted by noise and other experimental variabilities.

  15. Effective and efficient method of calculating Bessel beam fields

    CSIR Research Space (South Africa)

    Litvin, IA

    2005-01-01

    Full Text Available beams for SRS applications. However, to model the self reconstruction property of Bessel beams, it is necessary to calculate the field at all points in space before and after the obstacle – a computationally intensive task give the large spatial...

  16. Overdiagnosis associated with breast cancer screening: A simulation study to compare lead-time adjustment methods.

    Science.gov (United States)

    Seigneurin, A; Labarère, J; Duffy, S W; Colonna, M

    2015-12-01

    Estimating overdiagnosis associated with breast cancer screening may use annual incidence rates of cancer. We simulated populations invited to screening programmes to assess two lead-time adjustment methods. Overdiagnosis estimates were computed using the compensatory drop method, which considered the decrease in incidence of cancers among older age groups no longer offered screening, and the method based on the decrease in incidence of late-stage cancers. The true value of overdiagnosis was 0% in all the data sets simulated. The compensatory drop method yielded an overdiagnosis estimate of -0.1% (95% credibility interval -0.5% to 0.5%) when participation rates among the population and risk of cancers were constant. However, if participation rates increased with calendar year as well as risk of cancer with birth cohorts, the overdiagnosis estimated was 11.0% (10.5-11.6%). Using the method based on the incidence of early- and late-stage cancers, overdiagnosis estimates were 8.9% (8.5-9.3%) and 17.6% (17.4-17.9%) when participation rates and risks of cancer were constant or increased with time, respectively. Adjustment for lead time based on the compensatory drop method is accurate only when participation rates and risks of cancer remain constant, whereas the adjustment method based on the incidence of early- and late-stage cancers results in overestimating overdiagnosis regardless of stability of participation rates and breast cancer risk. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Realistic PIC modelling of laser-plasma interaction: a direct implicit method with adjustable damping and high order weight functions

    International Nuclear Information System (INIS)

    Drouin, M.

    2009-11-01

    This research thesis proposes a new formulation of the relativistic implicit direct method, based on the weak formulation of the wave equation which is solved by means of a Newton algorithm. The first part of this thesis deals with the properties of the explicit particle-in-cell (PIC) methods: properties and limitations of an explicit PIC code, linear analysis of a numerical plasma, numerical heating phenomenon, interest of a higher order interpolation function, and presentation of two applications in high density relativistic laser-plasma interaction. The second and main part of this report deals with adapting the direct implicit method to laser-plasma interaction: presentation of the state of the art, formulating of the direct implicit method, resolution of the wave equation. The third part concerns various numerical and physical validations of the ELIXIRS code: case of laser wave propagation in vacuum, demonstration of the adjustable damping which is a characteristic of the proposed algorithm, influence of space-time discretization on energy conservation, expansion of a thermal plasma in vacuum, two cases of plasma-beam unsteadiness in relativistic regime, and then a case of the overcritical laser-plasma interaction

  18. IC layout adjustment method and tool for improving dielectric reliability at interconnects

    Energy Technology Data Exchange (ETDEWEB)

    Kahng, Andrew B.; Chan, Tuck Boon

    2018-03-20

    Method for adjusting a layout used in making an integrated circuit includes one or more interconnects in the layout that are susceptible to dielectric breakdown are selected. One or more selected interconnects are adjusted to increase via to wire spacing with respect to at least one via and one wire of the one or more selected interconnects. Preferably, the selecting analyzes signal patterns of interconnects, and estimates the stress ratio based on state probability of routed signal nets in the layout. An annotated layout is provided that describes distances by which one or more via or wire segment edges are to be shifted. Adjustments can include thinning and shifting of wire segments, and rotation of vias.

  19. Study of spectral response of a neutron filter. Design of a method to adjust spectra

    International Nuclear Information System (INIS)

    Colomb-Dolci, F.

    1999-02-01

    The first part of this thesis describes an experimental method which intends to determine a neutron spectrum in the epithermal range [1 eV -10 keV]. Based on measurements of reaction rates provided by activation foils, it gives flux level in each energy range corresponding to each probe. This method can be used in any reactor location or in a neutron beam. It can determine scepter on eight energy groups, five groups in the epithermal range. The second part of this thesis presents a study of an epithermal neutron beam design, in the frame of Neutron Capture Therapy. A beam tube was specially built to test filters made up of different materials. Its geometry was designed to favour epithermal neutron crossing and to cut thermal and fast neutrons. A code scheme was validated to simulate the device response with a Monte Carlo code. Measurements were made at ISIS reactor and experimental spectra were compared to calculated ones. This validated code scheme was used to simulate different materials usable as shields in the tube. A study of these shields is presented at the end of this thesis. (author)

  20. Monte Carlo Method with Heuristic Adjustment for Irregularly Shaped Food Product Volume Measurement

    Directory of Open Access Journals (Sweden)

    Joko Siswantoro

    2014-01-01

    Full Text Available Volume measurement plays an important role in the production and processing of food products. Various methods have been proposed to measure the volume of food products with irregular shapes based on 3D reconstruction. However, 3D reconstruction comes with a high-priced computational cost. Furthermore, some of the volume measurement methods based on 3D reconstruction have a low accuracy. Another method for measuring volume of objects uses Monte Carlo method. Monte Carlo method performs volume measurements using random points. Monte Carlo method only requires information regarding whether random points fall inside or outside an object and does not require a 3D reconstruction. This paper proposes volume measurement using a computer vision system for irregularly shaped food products without 3D reconstruction based on Monte Carlo method with heuristic adjustment. Five images of food product were captured using five cameras and processed to produce binary images. Monte Carlo integration with heuristic adjustment was performed to measure the volume based on the information extracted from binary images. The experimental results show that the proposed method provided high accuracy and precision compared to the water displacement method. In addition, the proposed method is more accurate and faster than the space carving method.

  1. Monte Carlo method with heuristic adjustment for irregularly shaped food product volume measurement.

    Science.gov (United States)

    Siswantoro, Joko; Prabuwono, Anton Satria; Abdullah, Azizi; Idrus, Bahari

    2014-01-01

    Volume measurement plays an important role in the production and processing of food products. Various methods have been proposed to measure the volume of food products with irregular shapes based on 3D reconstruction. However, 3D reconstruction comes with a high-priced computational cost. Furthermore, some of the volume measurement methods based on 3D reconstruction have a low accuracy. Another method for measuring volume of objects uses Monte Carlo method. Monte Carlo method performs volume measurements using random points. Monte Carlo method only requires information regarding whether random points fall inside or outside an object and does not require a 3D reconstruction. This paper proposes volume measurement using a computer vision system for irregularly shaped food products without 3D reconstruction based on Monte Carlo method with heuristic adjustment. Five images of food product were captured using five cameras and processed to produce binary images. Monte Carlo integration with heuristic adjustment was performed to measure the volume based on the information extracted from binary images. The experimental results show that the proposed method provided high accuracy and precision compared to the water displacement method. In addition, the proposed method is more accurate and faster than the space carving method.

  2. Study of biomaterials by ion-beam based methods

    International Nuclear Information System (INIS)

    Racolta, Petru; Craciun, Liviu; Cincu, Emanuela; Voiculescu, Dana; Muresan, Ofelia; Serban, Alin; Filip, Andrei Ilie; Bunea, Danil; Antoniac, Vasile; Tudor, Tiberiu Laurian; Visan, Teodor; Visan, Sanda; Ibris, Neluta

    2002-01-01

    the primary beam and is activated following the nuclear reaction A(a,b)B. Some generated radioactive heavy ions B acquire sufficient kinetic energy to recoil out of the target and be implanted in the material. The nuclear reaction 56 Fe(p,n) 56 Co has been chosen to apply the UTLA (Ultra Thin Layer Activation) method because of its high cross section. Moreover, the half-life T= 77.1 days and the 846 keV gamma ray of the 56 Co radioelement is well suited for this study. The radioactive ions are implanted into the near surface (a few hundred nanometers). Wear/corrosion rate of the component by using tribological testers is observed via the variation of its activity caused by the loss of material. The layout of the experimental setup is presented as well as the angular distribution of the implanted recoil ions. In case of direct method the nuclear reaction occurs on the material surface. In order to obtain supplementary data concerning radiation influence on polyethylene samples doses up to 100 kGy were used. The advantages of this technique is the possibility to extend its applicability to any kind of solid material: plastics, ceramics, semiconductors , and metals. (authors)

  3. Method of active charge and current neutralization of intense ion beams for ICF

    International Nuclear Information System (INIS)

    Guiragossian, Z.G.T.; Orthel, J.L.; Lemons, D.S.; Thode, L.E.

    1981-01-01

    Methods of generating the beam neutralization electrons with required properties are given in the context of a Light Ion Fusion Experiment (LIFE) designed accelerator. Recently derived envelope equations for neutralized and ballistically focused intense ion beams are applied to the LIFE geometry in which 10 MeV He + multiple beamlets coalesce and undergo 45:1 radial compression while beam pulses experience a 20:1 axial compression in the propagation range of 10 m. Both active and auto-neutralization methods are examined and found to produce initial electron temperatures consistent with the requirement of the envelope equation for both radial and axial adiabatic beam pulse compressions. The stability of neutralized beam propagation is also examined concerning the Pierce type electrostatic instability and for the case of LIFE beams it is found to have insignificant effect. A scaled experimental setup is presented which can serve to perform near term tests on the ballistically focused propagation of neutralized light ion beams

  4. Analytical examination of a spiral beam scanning method for uniform irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Fukuda, Mitsuhiro; Okumura, Susumu; Arakawa, Kazuo [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

    1997-03-01

    A new circular beam scanning method for uniform irradiation of high-energy, intense ion beams over a large area has been developed. A sweeping speed and a trajectory density in a radial direction are kept constant to obtain uniform fluence distribution. A radial position of a beam spot on a target and an angular frequency of the circular motion are expressed by an irrational function of time. The beam is swept continuously, and a beam trajectory becomes spiral. More than 90 % uniformity of the fluence distribution can been achieved over a large area. (author)

  5. Radioactive ion beam production by the ISOL method for SPIRAL

    International Nuclear Information System (INIS)

    Landre-Pellemoine, Frederique

    2001-01-01

    This work is directly related to the SPIRAL project (Systeme de Production d'Ions Radioactifs Acceleres en Lignes) of which the start up will begin in September 2001 at GANIL (Grand Accelerateur National d'Ions Lourds) in Caen. This thesis primarily concerns the development of radioactive ion production systems (target/ion source) by the thorough study of each production stage of the ISOL (Isotopic Separation On Line) method: target and/or projectile fragmentation production, diffusion out of target material, effusion into the ion source and finally the ionization of the radioactive atoms. A bibliographical research and thermal simulations allowed us to optimize materials and the shape of the production and diffusion targets. A first target was optimized and made reliable for the radioactive noble gases production (argon, neon...). A second target dedicated to the radioactive helium production was entirely designed and realised (from the specifications to the 'off line' and 'on line' tests). Finally, a third target source system was defined for singly-charged radioactive alkaline production. The intensities of secondary beams planned for SPIRAL are presented here. A detailed study of the diffusion effusion efficiency for these various targets showed that the use of a fine microstructure carbon (grain size of 1 μm) improved the diffusion and showed the importance of thickness of the lamella for the short lived isotope effusion. (author) [fr

  6. LHCb: A novel method for an absolute luminosity measurement at LHCb using beam-gas imaging

    CERN Multimedia

    Barschel, C

    2013-01-01

    A novel technique to measure the absolute luminosity at the Large Hadron Collider (LHC) using beam-gas interactions has been successfully used in the LHCb experiment. A gas injection device (SMOG) has been installed in the LHCb experiment to increase the pressure around the interaction point during dedicated fills. The Beam Gas Imaging method (BGI) has now the potential to surpass the accuracy of the commonly used van der Meer scan method (VDM). This poster presents the principles of the Beam Gas Imaging method used to measure the beam overlap integral. Furthermore the gas injection increased the accuracy measurement of the so-called ghost charges and also intensities per bunch.

  7. Some adjustments to the human capital and the friction cost methods.

    Science.gov (United States)

    Targoutzidis, Antonis

    2018-03-21

    The cost of lost output is a major component of the total cost of illness estimates, especially those for the cost of workplace accidents and diseases. The two main methods for estimating this output, namely the human capital and the friction cost method, lead to very different results, particularly for cases of long-term absence, which makes the choice of method a critical dilemma. Two hidden assumptions, one for each method, are identified in this paper: for human capital method, the assumption that had the accident not happened the individual would remain alive, healthy and employed until retirement, and for friction cost method, the assumption that any created vacancy is covered by an unemployed person. Relevant adjustments to compensate for their impact are proposed: (a) to depreciate the estimates of the human capital method for the risks of premature death, disability or unemployment and (b) to multiply the estimates of the friction cost method with the expected number of job shifts that will be caused by a disability. The impact of these adjustments on the final estimates is very important in terms of magnitude and can lead to better results for each method.

  8. Electrostatic dispersion lenses and ion beam dispersion methods

    Science.gov (United States)

    Dahl, David A [Idaho Falls, ID; Appelhans, Anthony D [Idaho Falls, ID

    2010-12-28

    An EDL includes a case surface and at least one electrode surface. The EDL is configured to receive through the EDL a plurality of ion beams, to generate an electrostatic field between the one electrode surface and either the case surface or another electrode surface, and to increase the separation between the beams using the field. Other than an optional mid-plane intended to contain trajectories of the beams, the electrode surface or surfaces do not exhibit a plane of symmetry through which any beam received through the EDL must pass. In addition or in the alternative, the one electrode surface and either the case surface or the other electrode surface have geometries configured to shape the field to exhibit a less abrupt entrance and/or exit field transition in comparison to another electrostatic field shaped by two nested, one-quarter section, right cylindrical electrode surfaces with a constant gap width.

  9. CRIS: A new method in isomeric beam production

    Directory of Open Access Journals (Sweden)

    Lynch K.M.

    2013-12-01

    Full Text Available The Collinear Resonance Ionization Spectroscopy (CRIS experiment at ISOLDE, CERN, uses laser radiation to stepwise excite and ionize an atomic beam for the purpose of ultra-sensitive detection of rare isotopes, and hyperfine-structure measurements. The technique also offers the ability to purify an ion beam that is heavily contaminated with radioactive isobars, including the ground state of an isotope from its isomer, allowing decay spectroscopy on nuclear isomeric states to be performed. The isomeric ion beam is selected by resonantly exciting one of its hyperfine structure levels, and subsequently ionizing it. This selectively ionized beam is deflected to a decay spectroscopy station (DSS. This consists of a rotating wheel implantation system for alpha- and beta-decay spectroscopy, and up to three germanium detectors around the implantation site for gamma-ray detection. Resonance ionization spectroscopy and the new technique of laser assisted nuclear decay spectroscopy have recently been performed at the CRIS beam line on the neutron-deficient francium isotopes. Here an overview of the two techniques will be presented, alongside a description of the CRIS beam line and DSS.

  10. A fast beam hardening correction method incorporated in a filtered back-projection based MAP algorithm

    Science.gov (United States)

    Luo, Shouhua; Wu, Huazhen; Sun, Yi; Li, Jing; Li, Guang; Gu, Ning

    2017-03-01

    The beam hardening effect can induce strong artifacts in CT images, which result in severely deteriorated image quality with incorrect intensities (CT numbers). This paper develops an effective and efficient beam hardening correction algorithm incorporated in a filtered back-projection based maximum a posteriori (BHC-FMAP). In the proposed algorithm, the beam hardening effect is modeled and incorporated into the forward-projection of the MAP to suppress beam hardening induced artifacts, and the image update process is performed by Feldkamp-Davis-Kress method based back-projection to speed up the convergence. The proposed BHC-FMAP approach does not require information about the beam spectrum or the material properties, or any additional segmentation operation. The proposed method was qualitatively and quantitatively evaluated using both phantom and animal projection data. The experimental results demonstrate that the BHC-FMAP method can efficiently provide a good correction of beam hardening induced artefacts.

  11. CALCULATION METHODS OF OPTIMAL ADJUSTMENT OF CONTROL SYSTEM THROUGH DISTURBANCE CHANNEL

    Directory of Open Access Journals (Sweden)

    I. M. Golinko

    2014-01-01

    Full Text Available In the process of automatic control system debugging the great attention is paid to determining formulas’ parameters of optimal dynamic adjustment of regulators, taking into account the dynamics of Objects control. In most cases the known formulas are oriented on design of automatic control system through channel “input-output definition”. But practically in all continuous processes the main task of all regulators is stabilization of output parameters. The Methods of parameters calculation for dynamic adjustment of regulations were developed. These methods allow to optimize the analog and digital regulators, taking into account minimization of regulated influences. There were suggested to use the fact of detuning and maximum value of regulated influence. As the automatic control system optimization with proportional plus reset controllers on disturbance channel is an unimodal task, the main algorithm of optimization is realized by Hooke – Jeeves method. For controllers optimization through channel external disturbance there were obtained functional dependences of parameters calculations of dynamic proportional plus reset controllers from dynamic characteristics of Object control. The obtained dependences allow to improve the work of controllers (regulators of automatic control on external disturbance channel and so it allows to improve the quality of regulation of transient processes. Calculation formulas provide high accuracy and convenience in usage. In suggested method there are no nomographs and this fact expels subjectivity of investigation in determination of parameters of dynamic adjustment of proportional plus reset controllers. Functional dependences can be used for calculation of adjustment of PR controllers in a great range of change of dynamic characteristics of Objects control.

  12. A Cross-Section Adjustment Method for Double Heterogeneity Problem in VHTGR Analysis

    International Nuclear Information System (INIS)

    Yun, Sung Hwan; Cho, Nam Zin

    2011-01-01

    Very High Temperature Gas-Cooled Reactors (VHTGRs) draw strong interest as candidates for a Gen-IV reactor concept, in which TRISO (tristructuralisotropic) fuel is employed to enhance the fuel performance. However, randomly dispersed TRISO fuel particles in a graphite matrix induce the so-called double heterogeneity problem. For design and analysis of such reactors with the double heterogeneity problem, the Monte Carlo method is widely used due to its complex geometry and continuous-energy capabilities. However, its huge computational burden, even in the modern high computing power, is still problematic to perform wholecore analysis in reactor design procedure. To address the double heterogeneity problem using conventional lattice codes, the RPT (Reactivityequivalent Physical Transformation) method considers a homogenized fuel region that is geometrically transformed to provide equivalent self-shielding effect. Another method is the coupled Monte Carlo/Collision Probability method, in which the absorption and nu-fission resonance cross-section libraries in the deterministic CPM3 lattice code are modified group-wise by the double heterogeneity factors determined by Monte Carlo results. In this paper, a new two-step Monte Carlo homogenization method is described as an alternative to those methods above. In the new method, a single cross-section adjustment factor is introduced to provide self-shielding effect equivalent to the self-shielding in heterogeneous geometry for a unit cell of compact fuel. Then, the homogenized fuel compact material with the equivalent cross-section adjustment factor is used in continuous-energy Monte Carlo calculation for various types of fuel blocks (or assemblies). The procedure of cross-section adjustment is implemented in the MCNP5 code

  13. Method Based on Confidence Radius to Adjust the Location of Mobile Terminals

    DEFF Research Database (Denmark)

    García-Fernández, Juan Antonio; Jurado-Navas, Antonio; Fernández-Navarro, Mariano

    2017-01-01

    of the geographical positions associated to all reported mobile terminals will be remarkable improved independent on the geolocation technique employed. The proposed method will move each position estimate towards a previously calculated area of confidence in a smart manner. This reduced area of confidence......The present paper details a technique for adjusting in a smart manner the position estimates of any user equipment given by different geolocation/positioning methods in a wireless radiofrequency communication network based on different strategies (observed time difference of arrival , angle...... is generated to guarantee that the real position of any mobile terminal is inside it with a (Formula presented.) of probability of certainty....

  14. Analysis of beam propagation characteristics in gain-guided, index antiguided fibers with the beam propagation method.

    Science.gov (United States)

    Ai, Fei; Qian, Jianqiang; Shi, Junfeng; Zhang, Machi

    2017-10-10

    The transmission properties of beams in gain fibers are studied with the complex refractive index beam propagation method (CRI-BPM). The method is checked by comparison with an analytic method. The behavior of a gain-guided, index antiguided (GG-IAG) fiber with different gain coefficients is studied. The simulation results show that the signal can transfer in the fiber with almost no loss when the gain coefficient reaches the threshold of the fundamental mode, and the shape of output spot will have no major changes when the gain coefficient is over the thresholds of high-order modes, even when the mode competition is not obvious. The CRI-BPM can predict the changes in light power and light mode at the same time, and will be very useful in the designing of fiber amplifiers and lasers with complex structures. More factors will be considered in this method to provide reference for practical application in our further research.

  15. Method and apparatus for real time imaging and monitoring of radiotherapy beams

    Science.gov (United States)

    Majewski, Stanislaw [Yorktown, VA; Proffitt, James [Newport News, VA; Macey, Daniel J [Birmingham, AL; Weisenberger, Andrew G [Yorktown, VA

    2011-11-01

    A method and apparatus for real time imaging and monitoring of radiation therapy beams is designed to preferentially distinguish and image low energy radiation from high energy secondary radiation emitted from a target as the result of therapeutic beam deposition. A detector having low sensitivity to high energy photons combined with a collimator designed to dynamically image in the region of the therapeutic beam target is used.

  16. Adjusting the Parameters of Metal Oxide Gapless Surge Arresters’ Equivalent Circuits Using the Harmony Search Method

    Directory of Open Access Journals (Sweden)

    Christos A. Christodoulou

    2017-12-01

    Full Text Available The appropriate circuit modeling of metal oxide gapless surge arresters is critical for insulation coordination studies. Metal oxide arresters present a dynamic behavior for fast front surges; namely, their residual voltage is dependent on the peak value, as well as the duration of the injected impulse current, and should therefore not only be represented by non-linear elements. The aim of the current work is to adjust the parameters of the most frequently used surge arresters’ circuit models by considering the magnitude of the residual voltage, as well as the dissipated energy for given pulses. In this aim, the harmony search method is implemented to adjust parameter values of the arrester equivalent circuit models. This functions by minimizing a defined objective function that compares the simulation outcomes with the manufacturer’s data and the results obtained from previous methodologies.

  17. Comparative study of beam losses and heat loads reduction methods in MITICA beam source

    Energy Technology Data Exchange (ETDEWEB)

    Sartori, E., E-mail: emanuele.sartori@igi.cnr.it; Agostinetti, P.; Dal Bello, S.; Marcuzzi, D.; Serianni, G.; Veltri, P. [Consorzio RFX, Euratom-ENEA association, C.so Stati Uniti 4, 35127 Padova (Italy); Sonato, P. [Consorzio RFX, Euratom-ENEA association, C.so Stati Uniti 4, 35127 Padova (Italy); Dipartimento di Ingegneria Elettrica, Padova University, Via Gradenigo 6/a, 35131 Padova (Italy)

    2014-02-15

    In negative ion electrostatic accelerators a considerable fraction of extracted ions is lost by collision processes causing efficiency loss and heat deposition over the components. Stripping is proportional to the local density of gas, which is steadily injected in the plasma source; its pumping from the extraction and acceleration stages is a key functionality for the prototype of the ITER Neutral Beam Injector, and it can be simulated with the 3D code AVOCADO. Different geometric solutions were tested aiming at the reduction of the gas density. The parameter space considered is limited by constraints given by optics, aiming, voltage holding, beam uniformity, and mechanical feasibility. The guidelines of the optimization process are presented together with the proposed solutions and the results of numerical simulations.

  18. Ultraviolet and electron beams: energy efficient methods of curing

    International Nuclear Information System (INIS)

    O'Hara, K.

    1982-01-01

    The use of ultraviolet or electron beam radiation for the curing of surface coatings is described. Examples are taken from a number of industries, particular attention being paid to the paper varnishing and printed circuit industries. The components of the coatings used in these processes and toxicology and safety aspects are considered. (author)

  19. Radiogram enhancement and linearization using the beam hardening correction method

    Czech Academy of Sciences Publication Activity Database

    Vavřík, Daniel; Jakůbek, J.

    2009-01-01

    Roč. 607, - (2009), s. 212-214 ISSN 0168-9002. [International Workshop on Radiation Imaging Detectors. Helsinky, 29.06.2008-03.07.2008] Institutional research plan: CEZ:AV0Z20710524 Keywords : beam hardening correction * flat-field correction * digital radiography Subject RIV: JB - Sensors, Measurment, Regulation Impact factor: 1.317, year: 2009

  20. Method and apparatus for rapid adjustment of process gas inventory in gaseous diffusion cascades

    International Nuclear Information System (INIS)

    Dyer, R.H.; Fowler, A.H.; Vanstrum, P.R.

    1977-01-01

    The invention relates to an improved method and system for making relatively large and rapid adjustments in the process gas inventory of an electrically powered gaseous diffusion cascade in order to accommodate scheduled changes in the electrical power available for cascade operation. In the preferred form of the invention, the cascade is readied for a decrease in electrical input by simultaneously withdrawing substreams of the cascade B stream into respective process-gas-freezing and storage zones while decreasing the datum-pressure inputs to the positioning systems for the cascade control valves in proportion to the weight of process gas so removed. Consequently, the control valve positions are substantially unchanged by the reduction in invention, and there is minimal disturbance of the cascade isotopic gradient. The cascade is readied for restoration of the power cut by simultaneously evaporating the solids in the freezing zones to regenerate the process gas substreams and introducing them to the cascade A stream while increasing the aforementioned datum pressure inputs in proportion to the weight of process gas so returned. In the preferred form of the system for accomplishing these operations, heat exchangers are provided for freezing, storing, and evaporating the various substreams. Preferably, the heat exchangers are connected to use existing cascade auxiliary systems as a heat sink. A common control is employed to adjust and coordinate the necessary process gas transfers and datum pressure adjustments

  1. High-speed fan-beam reconstruction using direct two-dimensional Fourier transform method

    International Nuclear Information System (INIS)

    Niki, Noboru; Mizutani, Toshio; Takahashi, Yoshizo; Inouye, Tamon.

    1984-01-01

    Since the first development of X-ray computer tomography (CT), various efforts have been made to obtain high quality of high-speed image. However, the development of high resolution CT and the ultra-high speed CT to be applied to hearts is still desired. The X-ray beam scanning method was already changed from the parallel beam system to the fan-beam system in order to greatly shorten the scanning time. Also, the filtered back projection (DFBP) method has been employed to directly processing fan-beam projection data as reconstruction method. Although the two-dimensional Fourier transform (TFT) method significantly faster than FBP method was proposed, it has not been sufficiently examined for fan-beam projection data. Thus, the ITFT method was investigated, which first executes rebinning algorithm to convert the fan-beam projection data to the parallel beam projection data, thereafter, uses two-dimensional Fourier transform. By this method, although high speed is expected, the reconstructed images might be degraded due to the adoption of rebinning algorithm. Therefore, the effect of the interpolation error of rebinning algorithm on the reconstructed images has been analyzed theoretically, and finally, the result of the employment of spline interpolation which allows the acquisition of high quality images with less errors has been shown by the numerical and visual evaluation based on simulation and actual data. Computation time was reduced to 1/15 for the image matrix of 512 and to 1/30 for doubled matrix. (Wakatsuki, Y.)

  2. A simple method for boosting the beam quality of commercial DPL

    Science.gov (United States)

    Zhang, Guang-Yin; Jiao, Zhi-Yong; Yan, Cai-Fan; Ding, Xin; Zhang, Chao-Bo; Zhang, Xiao-Hua; Gu, Xue-Wen; Song, Feng

    2003-12-01

    A simple method for boosting the beam quality of a commercial laser diode pumped laser (DPL) is put forward. By keeping one of the mirrors unchanged and the moving the other mirror a proper distance away from the laser rod, high beam quality laser output is realized.

  3. More on analyzing the reflection of a laser beam by a deformed highly reflective volume Bragg grating using iteration of the beam propagation method.

    Science.gov (United States)

    Shu, Hong; Mokhov, Sergiy; Zeldovich, Boris Ya; Bass, Michael

    2009-01-01

    A further extension of the iteration method for beam propagation calculation is presented that can be applied for volume Bragg gratings (VBGs) with extremely large grating strength. A reformulation of the beam propagation formulation is presented for analyzing the reflection of a laser beam by a deformed VBG. These methods will be shown to be very accurate and efficient. A VBG with generic z-dependent distortion has been analyzed using these methods.

  4. Creation of biomaterials using the dual beam IBAD methods

    International Nuclear Information System (INIS)

    Rajchel, B.; Jaworska, L.; Proniewicz, L.M.

    2001-01-01

    The Dual Beam Ion Assisted Deposition technique (IBAD) application for creation of the hard, biocompatible coating layers has been presented and discussed. As substrate the stainless steel, Ti, special titanium alloys, the Al 2 O 3 or other solid materials can be used. Presently, the biocompatible coating layers such as DLC (Diamond Like Coating), β-SiC, TiC, hydroxyapatite and thin coating layer based on Ca, P, O, H have been prepared and investigated

  5. The Aristotle score: a complexity-adjusted method to evaluate surgical results.

    Science.gov (United States)

    Lacour-Gayet, F; Clarke, D; Jacobs, J; Comas, J; Daebritz, S; Daenen, W; Gaynor, W; Hamilton, L; Jacobs, M; Maruszsewski, B; Pozzi, M; Spray, T; Stellin, G; Tchervenkov, C; Mavroudis And, C

    2004-06-01

    Quality control is difficult to achieve in Congenital Heart Surgery (CHS) because of the diversity of the procedures. It is particularly needed, considering the potential adverse outcomes associated with complex cases. The aim of this project was to develop a new method based on the complexity of the procedures. The Aristotle project, involving a panel of expert surgeons, started in 1999 and included 50 pediatric surgeons from 23 countries, representing the EACTS, STS, ECHSA and CHSS. The complexity was based on the procedures as defined by the STS/EACTS International Nomenclature and was undertaken in two steps: the first step was establishing the Basic Score, which adjusts only the complexity of the procedures. It is based on three factors: the potential for mortality, the potential for morbidity and the anticipated technical difficulty. A questionnaire was completed by the 50 centers. The second step was the development of the Comprehensive Aristotle Score, which further adjusts the complexity according to the specific patient characteristics. It includes two categories of complexity factors, the procedure dependent and independent factors. After considering the relationship between complexity and performance, the Aristotle Committee is proposing that: Performance = Complexity x Outcome. The Aristotle score, allows precise scoring of the complexity for 145 CHS procedures. One interesting notion coming out of this study is that complexity is a constant value for a given patient regardless of the center where he is operated. The Aristotle complexity score was further applied to 26 centers reporting to the EACTS congenital database. A new display of centers is presented based on the comparison of hospital survival to complexity and to our proposed definition of performance. A complexity-adjusted method named the Aristotle Score, based on the complexity of the surgical procedures has been developed by an international group of experts. The Aristotle score

  6. Dynamic analysis of an axially moving beam subject to inner pressure using finite element method

    Energy Technology Data Exchange (ETDEWEB)

    Hua, Hongliang; Qiu, Ming; Liao, Zhenqiang [Nanjing University of Science and Technology, Nanjing (China)

    2017-06-15

    A dynamic model of an axially moving flexible beam subject to an inner pressure is present. The coupling principle between a flexible beam and inner pressure is analyzed first, and the potential energy of the inner pressure due to the beam bending is derived using the principle of virtual work. A 1D hollow beam element contain inner pressure is established. The finite element method and Lagrange’s equation are used to derive the motion equations of the axially moving system. The dynamic responses are analyzed by Newmark-β time integration method. Based on the computed dynamic responses, the effects of inner pressure on beam dynamics are discussed. Some interesting phenomenon is observed.

  7. An online replanning method using warm start optimization and aperture morphing for flattening-filter-free beams

    International Nuclear Information System (INIS)

    Ahunbay, Ergun E.; Ates, O.; Li, X. A.

    2016-01-01

    Purpose: In a situation where a couch shift for patient positioning is not preferred or prohibited (e.g., MR-linac), segment aperture morphing (SAM) can address target dislocation and deformation. For IMRT/VMAT with flattening-filter-free (FFF) beams, however, SAM method would lead to an adverse translational dose effect due to the beam unflattening. Here the authors propose a new two-step process to address both the translational effect of FFF beams and the target deformation. Methods: The replanning method consists of an offline and an online step. The offline step is to create a series of preshifted-plans (PSPs) obtained by a so-called “warm start” optimization (starting optimization from the original plan, rather than from scratch) at a series of isocenter shifts. The PSPs all have the same number of segments with very similar shapes, since the warm start optimization only adjusts the MLC positions instead of regenerating them. In the online step, a new plan is obtained by picking the closest PSP or linearly interpolating the MLC positions and the monitor units of the closest PSPs for the shift determined from the image of the day. This two-step process is completely automated and almost instantaneous (no optimization or dose calculation needed). The previously developed SAM algorithm is then applied for daily deformation. The authors tested the method on sample prostate and pancreas cases. Results: The two-step interpolation method can account for the adverse dose effects from FFF beams, while SAM corrects for the target deformation. Plan interpolation method is effective in diminishing the unflat beam effect and may allow reducing the required number of PSPs. The whole process takes the same time as the previously reported SAM process (5–10 min). Conclusions: The new two-step method plus SAM can address both the translation effects of FFF beams and target deformation, and can be executed in full automation except the delineation of target contour

  8. General beam position controlling method for 3D optical systems based on the method of solving ray matrix equations

    Science.gov (United States)

    Chen, Meixiong; Yuan, Jie; Long, Xingwu; Kang, Zhenglong; Wang, Zhiguo; Li, Yingying

    2013-12-01

    A general beam position controlling method for 3D optical systems based on the method of solving ray matrix equations has been proposed in this paper. As a typical 3D optical system, nonplanar ring resonator of Zero-Lock Laser Gyroscopes has been chosen as an example to show its application. The total mismatching error induced by Faraday-wedge in nonplanar ring resonator has been defined and eliminated quite accurately with the error less than 1 μm. Compared with the method proposed in Ref. [14], the precision of the beam position controlling has been improved by two orders of magnitude. The novel method can be used to implement automatic beam position controlling in 3D optical systems with servo circuit. All those results have been confirmed by related alignment experiments. The results in this paper are important for beam controlling, ray tracing, cavity design and alignment in 3D optical systems.

  9. A new method for improving beam quality of LINAC

    International Nuclear Information System (INIS)

    Xie Jialin; Li Fengtian; Wang Yanshan; Wang Bosi

    1999-01-01

    The principle of the self-adaptive feed-forward (SAFF) control to improve the beam quality of linac is introduced. the analytical procedure for calculating the control signals, the structure of a practical control system, and applications of SAFF in klystron, RF gun, and linac are presented, especially the application in the thermionic gun whose response is non-linear, time-variant and of large time-delay. The described control system is operational and some primary experimental results have been obtained, including the control of amplitude and phase fluctuations of the klystron output, the microwave field in the gun cavity and linac

  10. Beam Energy Measurement by Resonant Depolarization Method at VEPP-4M

    CERN Document Server

    Blinov, V E; Kaminskiy, V V; Kudryavtsev, V N; Nikitin, S A; Nikolaev, I B; Shekhtman, L I

    2017-01-01

    Experiments on high precision mass measurement of particles require precise beam energy calibration. The most accurate method of beam energy measurement is the resonant depolarization technique. This article describes the beam energy measurement at the VEPP-4M storage ring using this method together with a Touschek polarimeter. The accuracy achieved is about 10−6. More than thousand energy calibrations were used in the KEDR detector for the precise experiments on the measurement of J/ψ, ψ(2S), ψ(3770), D+, D0 meson and τ lepton masses.

  11. Modeling laser beam diffraction and propagation by the mode-expansion method.

    Science.gov (United States)

    Snyder, James J

    2007-08-01

    In the mode-expansion method for modeling propagation of a diffracted beam, the beam at the aperture can be expanded as a weighted set of orthogonal modes. The parameters of the expansion modes are chosen to maximize the weighting coefficient of the lowest-order mode. As the beam propagates, its field distribution can be reconstructed from the set of weighting coefficients and the Gouy phase of the lowest-order mode. We have developed a simple procedure to implement the mode-expansion method for propagation through an arbitrary ABCD matrix, and we have demonstrated that it is accurate in comparison with direct calculations of diffraction integrals and much faster.

  12. A Newton-Raphson Method Approach to Adjusting Multi-Source Solar Simulators

    Science.gov (United States)

    Snyder, David B.; Wolford, David S.

    2012-01-01

    NASA Glenn Research Center has been using an in house designed X25 based multi-source solar simulator since 2003. The simulator is set up for triple junction solar cells prior to measurements b y adjusting the three sources to produce the correct short circuit current, lsc, in each of three AM0 calibrated sub-cells. The past practice has been to adjust one source on one sub-cell at a time, iterating until all the sub-cells have the calibrated Isc. The new approach is to create a matrix of measured lsc for small source changes on each sub-cell. A matrix, A, is produced. This is normalized to unit changes in the sources so that Ax(delta)s = (delta)isc. This matrix can now be inverted and used with the known Isc differences from the AM0 calibrated values to indicate changes in the source settings, (delta)s = A ·'x.(delta)isc This approach is still an iterative one, but all sources are changed during each iteration step. It typically takes four to six steps to converge on the calibrated lsc values. Even though the source lamps may degrade over time, the initial matrix evaluation i s not performed each time, since measurement matrix needs to be only approximate. Because an iterative approach is used the method will still continue to be valid. This method may become more important as state-of-the-art solar cell junction responses overlap the sources of the simulator. Also, as the number of cell junctions and sources increase, this method should remain applicable.

  13. Radioactive ion beams of 111In using ECR plasma sputtering method

    Science.gov (United States)

    Naik, Vaishali; Bhattacharjee, Mahuwa; Kumar, D. Lavanya; Karmakar, Prasanta; Das, S. K.; Banerjee, Debashis; Chattopadhyay, Sankha; Barua, Luna; Das, Sujata Saha; Pal, Asit Kumar; Bandyopadhyay, Arup; Chakrabarti, Alok

    2017-06-01

    Radioactive ion beams of 111In (indium-111, half-life 2.8 days) have been produced using the plasma sputtering method in an electron cyclotron resonance (ECR) ion source at the Variable Energy Cyclotron Centre RIB facility. Indium isotopes were first produced by bombarding a natural silver target with a 32 MeV, 40 μ A alpha particle beam from the K-130 cyclotron. After radio-chemical separation, about 25 mCi In-chloride was deposited on an aluminum electrode and inserted in the plasma chamber of the ECR. Indium ions produced by ion induced sputtering in the plasma were extracted from the ion source, isotopically separated, and a pure 111In beam was measured at the focal plane of the separator. The measured 111In beam intensity was 2.67 × 105 particles/s for a beam energy of 5 keV.

  14. Methods for increasing the etching uniformity of ion beam multiple mask

    Science.gov (United States)

    Zhang, Xiaobo; Xiong, Ying; Liu, Qiang; Tian, Yangchao

    2009-05-01

    With uniform illumination, multi-step diffractive optical elements (DOE) are fabricated with ion beam multiple mask etching technology. According to the technical process of ion beam multiple mask etching on DOE, a distribution of surface error based on LKJ-150 ion beam etching machine is presented. Numerical analysis indicates that the surface distribution of etching error results in lower performance of multi-step DOE, which consumedly reduces the uniformity of target field with uniform illumination. After each etching process, the sample i.e, multi-step DOE fabricated by LKJ-150 ion beam etching machine is measured. Through measurement data, we get the etching error. On the basis of etching error, the mask can be made. Numerical analysis shows this method can reduce the impact of surface error on the performance of DOE and increase the etching uniformity of. ion beam multiple mask

  15. A method for measuring the time structure of synchrotron x-ray beams

    International Nuclear Information System (INIS)

    Moses, W.W.; Derenzo, S.E.

    1989-08-01

    We describe a method employing a plastic scintillator coupled to a fast photomultiplier tube to generate a timing pulse from the x-ray bursts emitted from a synchrotron radiation source. This technique is useful for performing synchrotron experiments where detailed knowledge of the timing distribution is necessary, such as time resolved spectroscopy or fluorescence lifetime experiments. By digitizing the time difference between the timing signal generated on one beam crossing with the timing signal generated on the next beam crossing, the time structure of a synchrotron beam can be analyzed. Using this technique, we have investigated the single bunch time structure at the National Synchrotron Light Source (NSLS) during pilot runs in January, 1989, and found that the majority of the beam (96%) is contained in one rf bucket, while the remainder of the beam (4%) is contained in satellite rf buckets preceeding and following the main rf bucket by 19 ns. 1 ref., 4 figs

  16. [Effect of 2 methods of occlusion adjustment on occlusal balance and muscles of mastication in patient with implant restoration].

    Science.gov (United States)

    Wang, Rong; Xu, Xin

    2015-12-01

    To compare the effect of 2 methods of occlusion adjustment on occlusal balance and muscles of mastication in patients with dental implant restoration. Twenty patients, each with a single edentulous posterior dentition with no distal dentition were selected, and divided into 2 groups. Patients in group A underwent original occlusion adjustment method and patients in group B underwent occlusal plane reduction technique. Ankylos implants were implanted in the edentulous space in each patient and restored with fixed prosthodontics single unit crown. Occlusion was adjusted in each restoration accordingly. Electromyograms were conducted to determine the effect of adjustment methods on occlusion and muscles of mastication 3 months and 6 months after initial restoration and adjustment. Data was collected and measurements for balanced occlusal measuring standards were obtained, including central occlusion force (COF), asymmetry index of molar occlusal force(AMOF). Balanced muscles of mastication measuring standards were also obtained including measurements from electromyogram for the muscles of mastication and the anterior bundle of the temporalis muscle at the mandibular rest position, average electromyogram measurements of the anterior bundle of the temporalis muscle at the intercuspal position(ICP), Astot, masseter muscle asymmetry index, and anterior temporalis asymmetry index (ASTA). Statistical analysis was performed using Student 's t test with SPSS 18.0 software package. Three months after occlusion adjustment, parameters of the original occlusion adjustment method were significantly different between group A and group B in balanced occlusal measuring standards and balanced muscles of mastication measuring standards. Six months after occlusion adjustment, parameters of the original occlusion adjustment methods were significantly different between group A and group B in balanced muscles of mastication measuring standards, but was no significant difference in balanced

  17. Diffraction-free, self-reconstructing Bessel beam generation using thermal nonlinear optical effect

    Science.gov (United States)

    Zhang, Q.; Cheng, X. M.; Chen, H. W.; He, B.; Ren, Z. Y.; Zhang, Y.; Bai, J. T.

    2017-10-01

    We propose a method to generate a Bessel beam using cross-phase modulation based on the thermal nonlinear optical effect. The thermal nonlinear medium is shown to have the ability to vary a Gaussian beam (probe beam) into a hollow beam when the medium is illuminated with a counter-propagating Gaussian beam (pump beam). It is demonstrated that this method has no restriction to the probe beam wavelength. Moreover, the generated Bessel beam exhibits superior non-diffraction properties during propagation and self-healing after encountering an obstruction on the beam path. The parameters of the beam can be easily adjusted by both the pump beam power and the sample concentration. The merits of variable parameters, no requirement for input beam wavelengths, simple setup, and low-cost would make this method significant in a variety of applications, especially in those areas where the parameters of the Bessel beam need to be easily adjusted without changing the setup.

  18. Analysis method of beam pointing stability based on optical transmission matrix

    Science.gov (United States)

    Wang, Chuanchuan; Huang, PingXian; Li, Xiaotong; Cen, Zhaofen

    2016-10-01

    Quite a lot of factors will make effects on beam pointing stability of an optical system, Among them, the element tolerance is one of the most important and common factors. In some large laser systems, it will make final micro beams spot on the image plane deviate obviously. So it is essential for us to achieve effective and accurate analysis theoretically on element tolerance. In order to make the analysis of beam pointing stability convenient and theoretical, we consider transmission of a single chief ray rather than beams approximately to stand for the whole spot deviation. According to optical matrix, we also simplify this complex process of light transmission to multiplication of many matrices. So that we can set up element tolerance model, namely having mathematical expression to illustrate spot deviation in an optical system with element tolerance. In this way, we can realize quantitative analysis of beam pointing stability theoretically. In second half of the paper, we design an experiment to get the spot deviation in a multipass optical system caused by element tolerance, then we adjust the tolerance step by step and compare the results with the datum got from tolerance model, finally prove the correction of tolerance model successfully.

  19. Optical method for mapping the transverse phase space of a charged particle beam

    International Nuclear Information System (INIS)

    Fiorito, R.B.; Shkvarunets, A.G.; O'Shea, P.G.

    2002-01-01

    We are developing an all optical method to map the transverse phase space map of a charged particle beam. Our technique employs OTR interferometry (OTRI) in combination with a scanning pinhole to make local orthogonal (x,y) divergence and trajectory angle measurements as function of position within the transverse profile of the beam. The localized data allows a reconstruction of the horizontal and vertical phase spaces of the beam. We have also demonstrated how single and multiple pinholes can in principle be used to make such measurements simultaneously

  20. Beam-pointing error compensation method of phased array radar seeker with phantom-bit technology

    Directory of Open Access Journals (Sweden)

    Qiuqiu WEN

    2017-06-01

    Full Text Available A phased array radar seeker (PARS must be able to effectively decouple body motion and accurately extract the line-of-sight (LOS rate for target missile tracking. In this study, the real-time two-channel beam pointing error (BPE compensation method of PARS for LOS rate extraction is designed. The PARS discrete beam motion principium is analyzed, and the mathematical model of beam scanning control is finished. According to the principle of the antenna element shift phase, both the antenna element shift phase law and the causes of beam-pointing error under phantom-bit conditions are analyzed, and the effect of BPE caused by phantom-bit technology (PBT on the extraction accuracy of the LOS rate is examined. A compensation method is given, which includes coordinate transforms, beam angle margin compensation, and detector dislocation angle calculation. When the method is used, the beam angle margin in the pitch and yaw directions is calculated to reduce the effect of the missile body disturbance and to improve LOS rate extraction precision by compensating for the detector dislocation angle. The simulation results validate the proposed method.

  1. Apparatus for and method of correcting for aberrations in a light beam

    International Nuclear Information System (INIS)

    Sawicki, R.H.

    1996-01-01

    A technique for adjustably correcting for aberrations in a light beam is disclosed herein. This technique utilizes first means which defines a flat, circular light reflecting surface having opposite reinforced circumferential edges and a central post and which is resiliently distortable, to a limited extent, into different concave and/or convex curvatures, which may be Gaussian-like, about the central axis, and second means acting on the first means for adjustably distorting the light reflecting surface into a particular selected one of the different curvatures depending upon the aberrations to be corrected for and for fixedly maintaining the curvature selected. In the embodiment disclosed, the light reflecting surface is adjustably distorted into the selected curvature by application of particular axial moments to the central post on the opposite side from the light reflecting surface and lateral moments to the circumference of the reflecting surface. 8 figs

  2. Material-Point Method Analysis of Bending in Elastic Beams

    DEFF Research Database (Denmark)

    Andersen, Søren Mikkel; Andersen, Lars

    2007-01-01

    The aim of this paper is to rest different kinds of spatial interpolation for the material-point method.......The aim of this paper is to rest different kinds of spatial interpolation for the material-point method....

  3. Accurate finite difference beam propagation method for complex integrated optical structures

    DEFF Research Database (Denmark)

    Rasmussen, Thomas; Povlsen, Jørn Hedegaard; Bjarklev, Anders Overgaard

    1993-01-01

    A simple and effective finite-difference beam propagation method in a z-varying nonuniform mesh is developed. The accuracy and computation time for this method are compared with a standard finite-difference method for both the 3-D and 2-D versions...

  4. The adjusting method of γ-ray diffraction equipment for analyzing the crystal mosaic of neutron monochromator

    International Nuclear Information System (INIS)

    Yang Zunyong; Xu Jiayun; Yao Zhenqiang; Yao Maoying; Wang Mingqiu; Xie Chaomei; Wang Xiaoying

    2011-01-01

    Gamma diffraction can be used for analyzing the crystal mosaic of neutron monochromator. As γ ray wavelength is short and high resolution is required for the analysis of crystal mosaic distribution, a elaborate geometric composition of γ-ray diffraction equipment is essential, and such a equipment can be achieved only through adjusting precisely the placement and orientation of all parts of the experiment. The adjusting methods are proposed. Through adjusting experiment according to the methods, the mosaic distribution of Ge single crystal monochromator was measured by γ-ray diffraction successfully with using a radioactive 198 Au source of 2 curies. (authors)

  5. System and method for dose verification and gamma ray imaging in ion beam therapy

    Energy Technology Data Exchange (ETDEWEB)

    Mihailescu, Lucian

    2017-12-26

    This disclosure provides systems, methods, and apparatus related to ion beam therapy. In one aspect, a system includes a position sensitive detector and a collimator. The position sensitive detector configured to detect gamma rays generated by an ion beam interacting with a target. The collimator is positioned between the target and the position sensitive detector. The collimator includes a plurality of knife-edge slits, with a first knife-edge slit intersecting with a second knife-edge slit.

  6. A Method for Eliminating Beam Steering Error for the Modulated Absorption-Emission Thermometry Technique

    Science.gov (United States)

    2015-01-01

    Beam Steering Error for the Modulated Absorption-Emission Thermometry Technique 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d...Jan 2015. PA#14562. 14. ABSTRACT Modulated absorption-emission thermometry (MAET) is a non-intrusive, radiometric technique for measuring line-of...ANSI Std. 239.18 1 Integrity  Service  Excellence A Method for Eliminating Beam Steering Error for Modulated Absorption- Emission Thermometry

  7. Numerical solution of reinforced concrete beam using arc-length method

    Directory of Open Access Journals (Sweden)

    Piotr Smarzewski

    2016-03-01

    Full Text Available This article discusses numerical solution of a reinforced concrete beam. The modelling was conducted with the rules of the finite element method (FEM. In order to verify the correctness of the assumed material’s models: concrete and reinforcing steel, the results obtained with the arc‑length method finite analysis were compared with experimental data. The method had been verified in the beam spatial model, in which concrete crushing at compressive and concrete stiffening at tensile are dominant phenomena. The arc-length method is the only one to offer the possibility of obtaining a complete load‑deflection curve with local and global softening.[b]Keywords[/b]: mechanics of concrete structures, finite element method, reinforced concrete beam, arc‑length algorithm

  8. Risk adjustment methods for Home Care Quality Indicators (HCQIs based on the minimum data set for home care

    Directory of Open Access Journals (Sweden)

    Hirdes John P

    2005-01-01

    Full Text Available Abstract Background There has been increasing interest in enhancing accountability in health care. As such, several methods have been developed to compare the quality of home care services. These comparisons can be problematic if client populations vary across providers and no adjustment is made to account for these differences. The current paper explores the effects of risk adjustment for a set of home care quality indicators (HCQIs based on the Minimum Data Set for Home Care (MDS-HC. Methods A total of 22 home care providers in Ontario and the Winnipeg Regional Health Authority (WRHA in Manitoba, Canada, gathered data on their clients using the MDS-HC. These assessment data were used to generate HCQIs for each agency and for the two regions. Three types of risk adjustment methods were contrasted: a client covariates only; b client covariates plus an "Agency Intake Profile" (AIP to adjust for ascertainment and selection bias by the agency; and c client covariates plus the intake Case Mix Index (CMI. Results The mean age and gender distribution in the two populations was very similar. Across the 19 risk-adjusted HCQIs, Ontario CCACs had a significantly higher AIP adjustment value for eight HCQIs, indicating a greater propensity to trigger on these quality issues on admission. On average, Ontario had unadjusted rates that were 0.3% higher than the WRHA. Following risk adjustment with the AIP covariate, Ontario rates were, on average, 1.5% lower than the WRHA. In the WRHA, individual agencies were likely to experience a decline in their standing, whereby they were more likely to be ranked among the worst performers following risk adjustment. The opposite was true for sites in Ontario. Conclusions Risk adjustment is essential when comparing quality of care across providers when home care agencies provide services to populations with different characteristics. While such adjustment had a relatively small effect for the two regions, it did

  9. Risk adjustment methods for Home Care Quality Indicators (HCQIs) based on the minimum data set for home care

    Science.gov (United States)

    Dalby, Dawn M; Hirdes, John P; Fries, Brant E

    2005-01-01

    Background There has been increasing interest in enhancing accountability in health care. As such, several methods have been developed to compare the quality of home care services. These comparisons can be problematic if client populations vary across providers and no adjustment is made to account for these differences. The current paper explores the effects of risk adjustment for a set of home care quality indicators (HCQIs) based on the Minimum Data Set for Home Care (MDS-HC). Methods A total of 22 home care providers in Ontario and the Winnipeg Regional Health Authority (WRHA) in Manitoba, Canada, gathered data on their clients using the MDS-HC. These assessment data were used to generate HCQIs for each agency and for the two regions. Three types of risk adjustment methods were contrasted: a) client covariates only; b) client covariates plus an "Agency Intake Profile" (AIP) to adjust for ascertainment and selection bias by the agency; and c) client covariates plus the intake Case Mix Index (CMI). Results The mean age and gender distribution in the two populations was very similar. Across the 19 risk-adjusted HCQIs, Ontario CCACs had a significantly higher AIP adjustment value for eight HCQIs, indicating a greater propensity to trigger on these quality issues on admission. On average, Ontario had unadjusted rates that were 0.3% higher than the WRHA. Following risk adjustment with the AIP covariate, Ontario rates were, on average, 1.5% lower than the WRHA. In the WRHA, individual agencies were likely to experience a decline in their standing, whereby they were more likely to be ranked among the worst performers following risk adjustment. The opposite was true for sites in Ontario. Conclusions Risk adjustment is essential when comparing quality of care across providers when home care agencies provide services to populations with different characteristics. While such adjustment had a relatively small effect for the two regions, it did substantially affect the

  10. Efficient Training of Supervised Spiking Neural Network via Accurate Synaptic-Efficiency Adjustment Method.

    Science.gov (United States)

    Xie, Xiurui; Qu, Hong; Yi, Zhang; Kurths, Jurgen

    2017-06-01

    The spiking neural network (SNN) is the third generation of neural networks and performs remarkably well in cognitive tasks, such as pattern recognition. The temporal neural encode mechanism found in biological hippocampus enables SNN to possess more powerful computation capability than networks with other encoding schemes. However, this temporal encoding approach requires neurons to process information serially on time, which reduces learning efficiency significantly. To keep the powerful computation capability of the temporal encoding mechanism and to overcome its low efficiency in the training of SNNs, a new training algorithm, the accurate synaptic-efficiency adjustment method is proposed in this paper. Inspired by the selective attention mechanism of the primate visual system, our algorithm selects only the target spike time as attention areas, and ignores voltage states of the untarget ones, resulting in a significant reduction of training time. Besides, our algorithm employs a cost function based on the voltage difference between the potential of the output neuron and the firing threshold of the SNN, instead of the traditional precise firing time distance. A normalized spike-timing-dependent-plasticity learning window is applied to assigning this error to different synapses for instructing their training. Comprehensive simulations are conducted to investigate the learning properties of our algorithm, with input neurons emitting both single spike and multiple spikes. Simulation results indicate that our algorithm possesses higher learning performance than the existing other methods and achieves the state-of-the-art efficiency in the training of SNN.

  11. Calculation of Credit Valuation Adjustment Based on Least Square Monte Carlo Methods

    Directory of Open Access Journals (Sweden)

    Qian Liu

    2015-01-01

    Full Text Available Counterparty credit risk has become one of the highest-profile risks facing participants in the financial markets. Despite this, relatively little is known about how counterparty credit risk is actually priced mathematically. We examine this issue using interest rate swaps. This largely traded financial product allows us to well identify the risk profiles of both institutions and their counterparties. Concretely, Hull-White model for rate and mean-reverting model for default intensity have proven to be in correspondence with the reality and to be well suited for financial institutions. Besides, we find that least square Monte Carlo method is quite efficient in the calculation of credit valuation adjustment (CVA, for short as it avoids the redundant step to generate inner scenarios. As a result, it accelerates the convergence speed of the CVA estimators. In the second part, we propose a new method to calculate bilateral CVA to avoid double counting in the existing bibliographies, where several copula functions are adopted to describe the dependence of two first to default times.

  12. A surrogate-based metaheuristic global search method for beam angle selection in radiation treatment planning.

    Science.gov (United States)

    Zhang, H H; Gao, S; Chen, W; Shi, L; D'Souza, W D; Meyer, R R

    2013-03-21

    An important element of radiation treatment planning for cancer therapy is the selection of beam angles (out of all possible coplanar and non-coplanar angles in relation to the patient) in order to maximize the delivery of radiation to the tumor site and minimize radiation damage to nearby organs-at-risk. This category of combinatorial optimization problem is particularly difficult because direct evaluation of the quality of treatment corresponding to any proposed selection of beams requires the solution of a large-scale dose optimization problem involving many thousands of variables that represent doses delivered to volume elements (voxels) in the patient. However, if the quality of angle sets can be accurately estimated without expensive computation, a large number of angle sets can be considered, increasing the likelihood of identifying a very high quality set. Using a computationally efficient surrogate beam set evaluation procedure based on single-beam data extracted from plans employing equallyspaced beams (eplans), we have developed a global search metaheuristic process based on the nested partitions framework for this combinatorial optimization problem. The surrogate scoring mechanism allows us to assess thousands of beam set samples within a clinically acceptable time frame. Tests on difficult clinical cases demonstrate that the beam sets obtained via our method are of superior quality.

  13. A surrogate-based metaheuristic global search method for beam angle selection in radiation treatment planning

    International Nuclear Information System (INIS)

    Zhang, H H; D’Souza, W D; Gao, S; Shi, L; Chen, W; Meyer, R R

    2013-01-01

    An important element of radiation treatment planning for cancer therapy is the selection of beam angles (out of all possible coplanar and non-coplanar angles in relation to the patient) in order to maximize the delivery of radiation to the tumor site and minimize radiation damage to nearby organs-at-risk. This category of combinatorial optimization problem is particularly difficult because direct evaluation of the quality of treatment corresponding to any proposed selection of beams requires the solution of a large-scale dose optimization problem involving many thousands of variables that represent doses delivered to volume elements (voxels) in the patient. However, if the quality of angle sets can be accurately estimated without expensive computation, a large number of angle sets can be considered, increasing the likelihood of identifying a very high quality set. Using a computationally efficient surrogate beam set evaluation procedure based on single-beam data extracted from plans employing equally-spaced beams (eplans), we have developed a global search metaheuristic process based on the nested partitions framework for this combinatorial optimization problem. The surrogate scoring mechanism allows us to assess thousands of beam set samples within a clinically acceptable time frame. Tests on difficult clinical cases demonstrate that the beam sets obtained via our method are of superior quality. (paper)

  14. Research of the Processing Method to Improve Joining Quality of Adjustable Cylindrical Adhesive Joints

    Directory of Open Access Journals (Sweden)

    A. V. Ignatov

    2017-01-01

    Full Text Available The BMSTU has solved a task of developing an original processing method to join cylindrical adhesive joints, which allows joining quality improvement. A key point of the method is that joining is vertically arranged and a forced air supply with a given amount of the airflow pressure and temperature is directed from the bottom end towards upper one. This method allows locking the adhesive composition in the gap and arrangement of conditions for curing an adhesive composition without its outflow. In this case it is possible to adjust mutual bracing of joining pieces to reach a specified joining accuracy till the cure of adhesive composition.To study a new method of joining, the BMSTU has built an experimental unit and carried out a set of experiments with an anaerobic adhesive composition Loctite 638 with varying the gap in the join within the range from 0.1 to 0.7 mm. In the course of experiments an empirical dependence of the critical shearing force on the gap value in the join has been derived, as well as the recommended conditions for air quality to hold the adhesive compositions depending on viscosity has been revealed. As a result of experimental research, it is found that for adhesive composition of low-viscosity from 20 to 1000 cSt, a range of air quality for holding the adhesive composition in the assembly gap is from 9.8 to 196 Pa; for adhesive composition of middle-viscosity from 1000 to 2000 cSt, the recommended conditions lie in the range from 197 to 735.5 Pa; for adhesive composition of high-viscosity from 2000 to 5000 cSt, the recommended assembly conditions are from 736 to 1471 Pa. The realized studies have shown that using a new joining method, the amount of used adhesive composition is by about 25% less, the labor hours of the joining process are two times decreased, and the joining strength obtained is increased on average by 10-15% as compared to the traditional assembly methods of the adhesive cylindrical joint. This method

  15. Interlaminar Stresses by Refined Beam Theories and the Sinc Method Based on Interpolation of Highest Derivative

    Science.gov (United States)

    Slemp, Wesley C. H.; Kapania, Rakesh K.; Tessler, Alexander

    2010-01-01

    Computation of interlaminar stresses from the higher-order shear and normal deformable beam theory and the refined zigzag theory was performed using the Sinc method based on Interpolation of Highest Derivative. The Sinc method based on Interpolation of Highest Derivative was proposed as an efficient method for determining through-the-thickness variations of interlaminar stresses from one- and two-dimensional analysis by integration of the equilibrium equations of three-dimensional elasticity. However, the use of traditional equivalent single layer theories often results in inaccuracies near the boundaries and when the lamina have extremely large differences in material properties. Interlaminar stresses in symmetric cross-ply laminated beams were obtained by solving the higher-order shear and normal deformable beam theory and the refined zigzag theory with the Sinc method based on Interpolation of Highest Derivative. Interlaminar stresses and bending stresses from the present approach were compared with a detailed finite element solution obtained by ABAQUS/Standard. The results illustrate the ease with which the Sinc method based on Interpolation of Highest Derivative can be used to obtain the through-the-thickness distributions of interlaminar stresses from the beam theories. Moreover, the results indicate that the refined zigzag theory is a substantial improvement over the Timoshenko beam theory due to the piecewise continuous displacement field which more accurately represents interlaminar discontinuities in the strain field. The higher-order shear and normal deformable beam theory more accurately captures the interlaminar stresses at the ends of the beam because it allows transverse normal strain. However, the continuous nature of the displacement field requires a large number of monomial terms before the interlaminar stresses are computed as accurately as the refined zigzag theory.

  16. Short term load forecasting technique based on the seasonal exponential adjustment method and the regression model

    International Nuclear Information System (INIS)

    Wu, Jie; Wang, Jianzhou; Lu, Haiyan; Dong, Yao; Lu, Xiaoxiao

    2013-01-01

    Highlights: ► The seasonal and trend items of the data series are forecasted separately. ► Seasonal item in the data series is verified by the Kendall τ correlation testing. ► Different regression models are applied to the trend item forecasting. ► We examine the superiority of the combined models by the quartile value comparison. ► Paired-sample T test is utilized to confirm the superiority of the combined models. - Abstract: For an energy-limited economy system, it is crucial to forecast load demand accurately. This paper devotes to 1-week-ahead daily load forecasting approach in which load demand series are predicted by employing the information of days before being similar to that of the forecast day. As well as in many nonlinear systems, seasonal item and trend item are coexisting in load demand datasets. In this paper, the existing of the seasonal item in the load demand data series is firstly verified according to the Kendall τ correlation testing method. Then in the belief of the separate forecasting to the seasonal item and the trend item would improve the forecasting accuracy, hybrid models by combining seasonal exponential adjustment method (SEAM) with the regression methods are proposed in this paper, where SEAM and the regression models are employed to seasonal and trend items forecasting respectively. Comparisons of the quartile values as well as the mean absolute percentage error values demonstrate this forecasting technique can significantly improve the accuracy though models applied to the trend item forecasting are eleven different ones. This superior performance of this separate forecasting technique is further confirmed by the paired-sample T tests

  17. Concept Modelling of Vehicle Joints and Beam-Like Structures through Dynamic FE-Based Methods

    Directory of Open Access Journals (Sweden)

    G. De Gaetano

    2014-01-01

    Full Text Available This paper presents dynamic methodologies able to obtain concept models of automotive beams and joints, which compare favourably with the existing literature methods, in terms of accuracy, easiness of implementation, and computational loads. For the concept beams, the proposed method is based on a dynamic finite element (FE approach, which estimates the stiffness characteristics of equivalent 1D beam elements using the natural frequencies, computed by a modal analysis of the detailed 3D FE model of the structure. Concept beams are then connected to each other by a concept joint, which is obtained through a dynamic reduction technique that makes use of its vibration normal modes. The joint reduction is improved through the application of a new interface beam-to-joint element, able to interpolate accurately the nodal displacements of the outer contour of the section, to obtain displacements and rotations of the central connection node. The proposed approach is validated through an application case that is typical in vehicle body engineering: the analysis of a structure formed by three spot-welded thin-walled beams, connected by a joint.

  18. Calculations for Adjusting Endogenous Biomarker Levels During Analytical Recovery Assessments for Ligand-Binding Assay Bioanalytical Method Validation.

    Science.gov (United States)

    Marcelletti, John F; Evans, Cindy L; Saxena, Manju; Lopez, Adriana E

    2015-07-01

    It is often necessary to adjust for detectable endogenous biomarker levels in spiked validation samples (VS) and in selectivity determinations during bioanalytical method validation for ligand-binding assays (LBA) with a matrix like normal human serum (NHS). Described herein are case studies of biomarker analyses using multiplex LBA which highlight the challenges associated with such adjustments when calculating percent analytical recovery (%AR). The LBA test methods were the Meso Scale Discovery V-PLEX® proinflammatory and cytokine panels with NHS as test matrix. The NHS matrix blank exhibited varied endogenous content of the 20 individual cytokines before spiking, ranging from undetectable to readily quantifiable. Addition and subtraction methods for adjusting endogenous cytokine levels in %AR calculations are both used in the bioanalytical field. The two methods were compared in %AR calculations following spiking and analysis of VS for cytokines having detectable endogenous levels in NHS. Calculations for %AR obtained by subtracting quantifiable endogenous biomarker concentrations from the respective total analytical VS values yielded reproducible and credible conclusions. The addition method, in contrast, yielded %AR conclusions that were frequently unreliable and discordant with values obtained with the subtraction adjustment method. It is shown that subtraction of assay signal attributable to matrix is a feasible alternative when endogenous biomarkers levels are below the limit of quantitation, but above the limit of detection. These analyses confirm that the subtraction method is preferable over that using addition to adjust for detectable endogenous biomarker levels when calculating %AR for biomarker LBA.

  19. On Approximate Analytical Solutions of Nonlinear Vibrations of Inextensible Beams using Parameter-Expansion Method

    DEFF Research Database (Denmark)

    Kimiaeifar, Amin; Lund, Erik; Thomsen, Ole Thybo

    2010-01-01

    In this work, an analytical method, which is referred to as Parameter-expansion Method is used to obtain the exact solution for the problem of nonlinear vibrations of an inextensible beam. It is shown that one term in the series expansion is sufficient to obtain a highly accurate solution, which...

  20. An angular multigrid method for computing mono-energetic particle beams in Flatland

    Science.gov (United States)

    Börgers, Christoph; MacLachlan, Scott

    2010-04-01

    Beams of microscopic particles penetrating scattering background matter play an important role in several applications. The parameter choices made here are motivated by the problem of electron-beam cancer therapy planning. Mathematically, a steady particle beam penetrating matter, or a configuration of several such beams, is modeled by a boundary value problem for a Boltzmann equation. Grid-based discretization of such a problem leads to a system of algebraic equations. This system is typically very large because of the large number of independent variables in the Boltzmann equation—six if no dimension-reducing assumptions other than time independence are made. If grid-based methods are to be practical for these problems, it is therefore necessary to develop very fast solvers for the discretized problems. For beams of mono-energetic particles interacting with a passive background, but not with each other, in two space dimensions, the first author proposed such a solver, based on angular domain decomposition, some time ago. Here, we propose and test an angular multigrid algorithm for the same model problem. Our numerical experiments show rapid, grid-independent convergence. For high-resolution calculations, our method is substantially more efficient than the angular domain decomposition method. In addition, unlike angular domain decomposition, the angular multigrid method works well even when the angular diffusion coefficient is fairly large.

  1. X-ray beam method for displacement measurement in hostile environments

    Science.gov (United States)

    Jordan, Eric H.; Pease, D. M.; Canistraro, H.; Brew, Dale

    1989-01-01

    A new method of extensometry using an X-ray beam was devised, and the results of current testing reveal it to be highly feasible. This technique has been shown to provide a non-contacting system that is immune to problems associated with density variations in gaseous environments, that plague currently available optical methods. This advantage is a result of the non-refracting penetrating nature of X-rays. The method is based on X-ray-induced X-ray fluorescence of targets, which subsequently serve as fudicial markers. Some target materials have melting points over 1600 degrees C which will facilitate measurement at extremely high temperatures. A highly focused intense X-ray beam, which is produced using a Johansen 'bent crystal', is then scanned across the target, which responds by fluorescing X-rays when stimulated by the incident beam. This secondary radiation is monitored using a detector. By carefully measuring beam orientation, change in target edge position can be determined. Many variations on this basic theme are now possible such as two targets demarcating a gage length, or a beam shadowing method using opaque targets.

  2. Application of the inverse estimation method of current distribution from magnetic fields using genetic algorithm to beam profile measurement

    International Nuclear Information System (INIS)

    Kishimoto, M.; Sakasai, K.; Ara, K.

    1994-01-01

    In this paper, the new type of non-invasive beam profile monitor for intense ion accelerator using high-temperature superconductor. We regard the inverse estimation problem of beam profile as the optimum allocation problem of the currents into the cross-section of the beam vacuum pipe and applied genetic algorithm to solve this optimization problem. And we carried out the computer simulation to verify the effectiveness of this inverse estimation method of beam profile. (author)

  3. Comparison of Force Reconstruction Methods for a Lumped Mass Beam

    Directory of Open Access Journals (Sweden)

    Vesta I. Bateman

    1997-01-01

    Full Text Available Two extensions of the force reconstruction method, the sum of weighted accelerations technique (SWAT, are presented in this article. SWAT requires the use of the structure’s elastic mode shapes for reconstruction of the applied force. Although based on the same theory, the two new techniques do not rely on mode shapes to reconstruct the applied force and may be applied to structures whose mode shapes are not available. One technique uses the measured force and acceleration responses with the rigid body mode shapes to calculate the scalar weighting vector, so the technique is called SWAT-CAL (SWAT using a calibrated force input. The second technique uses the free-decay time response of the structure with the rigid body mode shapes to calculate the scalar weighting vector and is called SWAT-TEEM (SWAT using time eliminated elastic modes. All three methods are used to reconstruct forces for a simple structure.

  4. Research of beam hardening correction method for CL system based on SART algorithm

    International Nuclear Information System (INIS)

    Cao Daquan; Wang Yaxiao; Que Jiemin; Sun Cuili; Wei Cunfeng; Wei Long

    2014-01-01

    Computed laminography (CL) is a non-destructive testing technique for large objects, especially for planar objects. Beam hardening artifacts were wildly observed in the CL system and significantly reduce the image quality. This study proposed a novel simultaneous algebraic reconstruction technique (SART) based beam hardening correction (BHC) method for the CL system, namely the SART-BHC algorithm in short. The SART-BHC algorithm took the polychromatic attenuation process in account to formulate the iterative reconstruction update. A novel projection matrix calculation method which was different from the conventional cone-beam or fan-beam geometry was also studied for the CL system. The proposed method was evaluated with simulation data and experimental data, which was generated using the Monte Carlo simulation toolkit Geant4 and a bench-top CL system, respectively. All projection data were reconstructed with SART-BHC algorithm and the standard filtered back projection (FBP) algorithm. The reconstructed images show that beam hardening artifacts are greatly reduced with the SART-BHC algorithm compared to the FBP algorithm. The SART-BHC algorithm doesn't need any prior know-ledge about the object or the X-ray spectrum and it can also mitigate the interlayer aliasing. (authors)

  5. System and method for sonic wave measurements using an acoustic beam source

    Science.gov (United States)

    Vu, Cung Khac; Sinha, Dipen N.; Pantea, Cristian

    2015-08-11

    A method and system for investigating structure near a borehole are described herein. The method includes generating an acoustic beam by an acoustic source; directing at one or more azimuthal angles the acoustic beam towards a selected location in a vicinity of a borehole; receiving at one or more receivers an acoustic signal, the acoustic signal originating from a reflection or a refraction of the acoustic wave by a material at the selected location; and analyzing the received acoustic signal to characterize features of the material around the borehole.

  6. A finite element beam propagation method for simulation of liquid crystal devices.

    Science.gov (United States)

    Vanbrabant, Pieter J M; Beeckman, Jeroen; Neyts, Kristiaan; James, Richard; Fernandez, F Anibal

    2009-06-22

    An efficient full-vectorial finite element beam propagation method is presented that uses higher order vector elements to calculate the wide angle propagation of an optical field through inhomogeneous, anisotropic optical materials such as liquid crystals. The full dielectric permittivity tensor is considered in solving Maxwell's equations. The wide applicability of the method is illustrated with different examples: the propagation of a laser beam in a uniaxial medium, the tunability of a directional coupler based on liquid crystals and the near-field diffraction of a plane wave in a structure containing micrometer scale variations in the transverse refractive index, similar to the pixels of a spatial light modulator.

  7. Equivalent circuit study of beam-loading using a moment method

    International Nuclear Information System (INIS)

    Wang, T.F.; Machida, S.; Mori, Y.; Ohmori, C.

    1997-01-01

    In this work, we present a formalism by considering the perturbations in the moments of a bunched beam for the equivalent circuit model to include all harmonics of the synchroton oscillation in a beam-cavity interaction system. The linear coupling among all longitudinal modes under the influence of narrow-band impedance can be naturally incorporated in this new approach. We used this method to re-examine the coupling between the dipole and the quadrupole modes. The dispersion relation obtained by this new method was compared with that derived from the linearized Vlasov equation up to the second harmonic of the synchrotron motion. We found excellent qualitative agreements between two approaches

  8. Differential Quadrature Method Based Study of Vibrational Behaviour of Inclined Edge Cracked Beams

    Directory of Open Access Journals (Sweden)

    Srivastava Shivani

    2017-01-01

    Full Text Available The study of vibration behaviour of cracked system is an important area of research. In the present work we present a mathematical model to study the effect of inclination, location and size of the crack on the vibrational behavior of beam with different boundary conditions. The model is based on the assumption that the equivalent flexible rigidity of the cracked beam can be written in terms of the flexible rigidity of the uncracked beam, based on the energy approach as proposed by earlier researchers. In the present work the Differential Quadrature Method (DQM is used to solve equation of motion derived by using Euler’s beam theory. The primary interest of the paper is to study the effect of inclined crack on natural frequency. We have also studied the beam vibration with and without vertical edge crack as a special case to validate the model. The DQM results for the natural frequencies of cracked beams agree well with other literature values and ANSYS solutions.

  9. Device and method for generating a beam of acoustic energy from a borehole, and applications thereof

    Science.gov (United States)

    Vu, Cung Khac; Sinha, Dipen N.; Pantea, Cristian; Nihei, Kurt T.; Schmitt, Denis P.; Skelt, Chirstopher

    2013-10-15

    In some aspects of the invention, a method of generating a beam of acoustic energy in a borehole is disclosed. The method includes generating a first acoustic wave at a first frequency; generating a second acoustic wave at a second frequency different than the first frequency, wherein the first acoustic wave and second acoustic wave are generated by at least one transducer carried by a tool located within the borehole; transmitting the first and the second acoustic waves into an acoustically non-linear medium, wherein the composition of the non-linear medium produces a collimated beam by a non-linear mixing of the first and second acoustic waves, wherein the collimated beam has a frequency based upon a difference between the first frequency range and the second frequency, and wherein the non-linear medium has a velocity of sound between 100 m/s and 800 m/s.

  10. The two-dimensional Gaussian beam synthetic method: Testing and application

    Science.gov (United States)

    Nowack, R.; Aki, K.

    1984-09-01

    The Gaussian beam method of Červený et al. (1982) is an asymptotic method for the computation of wave fields in inhomogeneous media. The method consists of tracing rays and then solving the wave equation in "ray-centered coordinates." The parabolic approximation is applied to find the asymptotic local solution in the neighborhod of each ray. The approximate global solution for a given source is then constructed by a superposition of Gaussian beams along nearby rays. The Gaussian beam method is tested in a two-dimensional inhomogeneous medium using two approaches. One is the application of the reciprocal theorem for Green's functions in an arbitrarily heterogeneous medium. The discrepancy between synthetic seismograms for reciprocal cases is considered as a measure of the error. The other approach is to apply Gaussian beam synthesis to cases for which solutions are known by other approximate methods. This includes the soft basin problem that has been studied by finite difference, finite element, discrete wavenumber, and glorified optics. We found that the results of these tests were in general satisfactory. We have used the Gaussian beam method for two applications. First, the method is used to study volcanic earthquakes at Mount Saint Helens. The observed large differences in amplitude and arrival time between a station inside the crater and stations on the flanks can be explained by the combined effects of an anomalous velocity structure and a shallow focal depth. The method is also applied to scattering of teleseismic P waves by a lithosphere with randomly fluctuating velocities.

  11. Treatment of liquid separated from sludge by the method using electron beam and ozone in combination

    International Nuclear Information System (INIS)

    Hosono, Masakazu; Arai, Hidehiko; Aizawa, Masaki; Shimooka, Toshio; Shimizu, Ken; Sugiyama, Masashi.

    1995-01-01

    Since the liquid separated from sludge in the dehydration or concentration process of sewer sludge contains considerable amount of organic compositions that are hard to be decomposed by microorganisms, it has become difficult to be treated by conventional activated sludge process. In the case of discharging the separated liquid into closed water areas, the higher quality treatment is required. The method of using electron beam irradiation and ozone oxidation in combination for cleaning the liquid separated from sludge was examined, therefore, the results are reported. The water quality of the sample from the sludge treatment plant in A City is shown. The method of bio-pretreatment, the treatment method by using electron beam and ozone in combination, and the method of analyzing the water quality are described. The effect of the treatment by activated sludge process, as the effect of the treatment by the combined use of electron beam and ozone, the change of COD and TOC, the change of chromaticity, the change of gel chromatogram, and the reaction mechanism are reported. In this paper, only the basic concept on the model plant for applying the method of the combined use of electron beam and ozone to the treatment of the liquid separated from sludge is discussed. (K.I.)

  12. A node-based smoothed point interpolation method for dynamic analysis of rotating flexible beams

    Science.gov (United States)

    Du, C. F.; Zhang, D. G.; Li, L.; Liu, G. R.

    2017-10-01

    We proposed a mesh-free method, the called node-based smoothed point interpolation method (NS-PIM), for dynamic analysis of rotating beams. A gradient smoothing technique is used, and the requirements on the consistence of the displacement functions are further weakened. In static problems, the beams with three types of boundary conditions are analyzed, and the results are compared with the exact solution, which shows the effectiveness of this method and can provide an upper bound solution for the deflection. This means that the NS-PIM makes the system soften. The NS-PIM is then further extended for solving a rigid-flexible coupled system dynamics problem, considering a rotating flexible cantilever beam. In this case, the rotating flexible cantilever beam considers not only the transverse deformations, but also the longitudinal deformations. The rigid-flexible coupled dynamic equations of the system are derived via employing Lagrange's equations of the second type. Simulation results of the NS-PIM are compared with those obtained using finite element method (FEM) and assumed mode method. It is found that compared with FEM, the NS-PIM has anti-ill solving ability under the same calculation conditions.

  13. Numerical computation methods for magnet design of spectrometer, accelerator and beam transport systems

    International Nuclear Information System (INIS)

    Fan Mingwu; Maio Yixin

    1986-01-01

    High calculation accuracy is expected in the design of spectrometer, accelerator or beam transport systems. Three dimensional electromagnetic field computation is needed in some cases. In solving these problems, numerical computation methods have been dominating in the area. Advantages and disadvantages among the methods are discussed and errors between computed and measured values are analysised. The application of making full use of these methods is discussed based on some practical models

  14. SU-F-P-28: A Method of Maximize the Noncoplanar Beam Orientations and Assure the Beam Delivery Clearance for Stereotactic Body Radiation Therapy (SBRT)

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, J [Presence St. Joseph Medical Ctr., Joliet, IL (United States)

    2016-06-15

    Purpose: Develop a method to maximize the noncoplanar beam orientations and assure the beam delivery clearance for SBRT, therefore, optimize the dose conformality to the target, increase the dose sparing to the critical normal organs and reduce the hot spots in the body. Methods: A SBRT body frame (Elekta, Stockholm, Sweden) was used for patient immobilization and target localization. The SBRT body frame has CT fiducials on its side frames. After patient’s CT scan, the radiation treatment isocenter was defined and its coordinators referring to the body frame was calculated in the radiation treatment planning process. Meanwhile, initial beam orientations were designed based on the patient target and critical organ anatomy. The body frame was put on the linear accelerator couch and positioned to the calculated isocenter. Initially designed beam orientations were manually measured by tuning the body frame position on the couch, the gantry and couch angles. The finalized beam orientations were put into the treatment planning for dosimetric calculations. Results: Without patient presence, an optimal set of beam orientations were designed and validated. The radiation treatment plan was optimized and guaranteed for delivery clearance. Conclusion: The developed method is beneficial and effective in SBRT treatment planning for individual patient. It first allows maximizing the achievable noncoplanar beam orientation space, therefore, optimize the treatment plan for specific patient. It eliminates the risk that a plan needs to be modified due to the gantry and couch collision during patient setup.

  15. Determining shear modulus of thin wood composite materials using a cantilever beam vibration method

    Science.gov (United States)

    Cheng Guan; Houjiang Zhang; John F. Hunt; Haicheng Yan

    2016-01-01

    Shear modulus (G) of thin wood composite materials is one of several important indicators that characterizes mechanical properties. However, there is not an easy method to obtain this value. This study presents the use of a newly developed cantilever beam free vibration test apparatus to detect in-plane G of thin wood composite...

  16. Reconstruction of electron beam distribution in phase space by using parallel maximum entropy method

    International Nuclear Information System (INIS)

    Hajima, R.; Hirotsu, T.; Kondo, S.

    1997-01-01

    Reconstruction of electron beam distribution in six-dimensional phase space by tomographic approach is presented. Maximum entropy method (MENT) is applied to the reconstruction and compared with filtered back-projection. Finally, MENT is adapted to parallel computing environment with PVM. (orig.)

  17. Beam shaping and its solution with the use of an optimization method.

    Science.gov (United States)

    Cong, W X; Chen, N X; Gu, B Y

    1998-07-10

    We present an exact mathematical description of beam shaping and indicate that a rigorous solution does not exist: only an optimal solution can be found. An optimization method is proposed to search for the solution. The simulation results for an example are given in detail.

  18. Moving gantry method for electron beam dose profile measurement at extended source-to-surface distances.

    Science.gov (United States)

    Fekete, Gábor; Fodor, Emese; Pesznyák, Csilla

    2015-03-08

    A novel method has been put forward for very large electron beam profile measurement. With this method, absorbed dose profiles can be measured at any depth in a solid phantom for total skin electron therapy. Electron beam dose profiles were collected with two different methods. Profile measurements were performed at 0.2 and 1.2 cm depths with a parallel plate and a thimble chamber, respectively. 108cm × 108 cm and 45 cm × 45 cm projected size electron beams were scanned by vertically moving phantom and detector at 300 cm source-to-surface distance with 90° and 270° gantry angles. The profiles collected this way were used as reference. Afterwards, the phantom was fixed on the central axis and the gantry was rotated with certain angular steps. After applying correction for the different source-to-detector distances and incidence of angle, the profiles measured in the two different setups were compared. Correction formalism has been developed. The agreement between the cross profiles taken at the depth of maximum dose with the 'classical' scanning and with the new moving gantry method was better than 0.5 % in the measuring range from zero to 71.9 cm. Inverse square and attenuation corrections had to be applied. The profiles measured with the parallel plate chamber agree better than 1%, except for the penumbra region, where the maximum difference is 1.5%. With the moving gantry method, very large electron field profiles can be measured at any depth in a solid phantom with high accuracy and reproducibility and with much less time per step. No special instrumentation is needed. The method can be used for commissioning of very large electron beams for computer-assisted treatment planning, for designing beam modifiers to improve dose uniformity, and for verification of computed dose profiles.

  19. Process qualification and control in electron beams--requirements, methods, new concepts and challenges

    International Nuclear Information System (INIS)

    Mittendorfer, J.; Gratzl, F.; Hanis, D.

    2004-01-01

    In this paper the status of process qualification and control in electron beam irradiation is analyzed in terms of requirements, concepts, methods and challenges for a state-of-the-art process control concept for medical device sterilization. Aspects from process qualification to routine process control are described together with the associated process variables. As a case study the 10 MeV beams at Mediscan GmbH are considered. Process control concepts like statistical process control (SPC) and a new concept to determine process capability is briefly discussed

  20. Simple emittance measurement of negative hydrogen ion beam using pepper-pot method

    Energy Technology Data Exchange (ETDEWEB)

    Hamabe, M.; Tsumori, K.; Takeiri, Y.; Kaneko, O.; Asano, E.; Kawamoto, T.; Kuroda, T. [National Inst. for Fusion Science, Nagoya (Japan); Guharay, S.K.

    1997-02-01

    A simple apparatus for emittance measurement using pepper-pot method is developed. The pepper-pot patterns are directly exposed and recorded on a Kapton foil. Using this apparatus, emittance was measured in the case of the negative hydrogen (H{sup -}) beam from the large negative ion source, which is the 1/3 scaled test device for the negative-ion-based neutral beam injection (N-NBI) on the Large Helical Device (LHD). As the consequence of the first trial, the 95% normalized emittance value is measured as 0.59 mm mrad. (author)

  1. Adaptive Laguerre-Gaussian variant of the Gaussian beam expansion method.

    Science.gov (United States)

    Cagniot, Emmanuel; Fromager, Michael; Ait-Ameur, Kamel

    2009-11-01

    A variant of the Gaussian beam expansion method consists in expanding the Bessel function J0 appearing in the Fresnel-Kirchhoff integral into a finite sum of complex Gaussian functions to derive an analytical expression for a Laguerre-Gaussian beam diffracted through a hard-edge aperture. However, the validity range of the approximation depends on the number of expansion coefficients that are obtained by optimization-computation directly. We propose another solution consisting in expanding J0 onto a set of collimated Laguerre-Gaussian functions whose waist depends on their number and then, depending on its argument, predicting the suitable number of expansion functions to calculate the integral recursively.

  2. Fractal Two-Level Finite Element Method For Free Vibration of Cracked Beams

    Directory of Open Access Journals (Sweden)

    A.Y.T. Leung

    1998-01-01

    Full Text Available The fractal two-level finite element method is extended to the free vibration behavior of cracked beams for various end boundary conditions. A cracked beam is separated into its singular and regular regions. Within the singular region, infinite number of finite elements are virturally generated by fractal geometry to model the singular behavior of the crack tip. The corresponding numerous degrees of freedom are reduced to a small set of generalized displacements by fractal transformation technique. The solution time and computer storage can be remarkably reduced without sacrifying accuracy. The resonant frequencies and mode shapes computed compared well with the results from a commercial program.

  3. Dynamic Analysis of a Timoshenko Beam Subjected to an Accelerating Mass Using Spectral Element Method

    Directory of Open Access Journals (Sweden)

    Guangsong Chen

    2014-01-01

    Full Text Available This paper presents formulations for a Timoshenko beam subjected to an accelerating mass using spectral element method in time domain (TSEM. Vertical displacement and bending rotation of the beam were interpolated by Lagrange polynomials supported on the Gauss-Lobatto-Legendre (GLL points. By using GLL integration rule, the mass matrix was diagonal and the dynamic responses can be obtained efficiently and accurately. The results were compared with those obtained in the literature to verify the correctness. The variation of the vibration frequencies of the Timoshenko and moving mass system was researched. The effects of inertial force, centrifugal force, Coriolis force, and tangential force on a Timoshenko beam subjected to an accelerating mass were investigated.

  4. The FLUKA code for application of Monte Carlo methods to promote high precision ion beam therapy

    CERN Document Server

    Parodi, K; Cerutti, F; Ferrari, A; Mairani, A; Paganetti, H; Sommerer, F

    2010-01-01

    Monte Carlo (MC) methods are increasingly being utilized to support several aspects of commissioning and clinical operation of ion beam therapy facilities. In this contribution two emerging areas of MC applications are outlined. The value of MC modeling to promote accurate treatment planning is addressed via examples of application of the FLUKA code to proton and carbon ion therapy at the Heidelberg Ion Beam Therapy Center in Heidelberg, Germany, and at the Proton Therapy Center of Massachusetts General Hospital (MGH) Boston, USA. These include generation of basic data for input into the treatment planning system (TPS) and validation of the TPS analytical pencil-beam dose computations. Moreover, we review the implementation of PET/CT (Positron-Emission-Tomography / Computed- Tomography) imaging for in-vivo verification of proton therapy at MGH. Here, MC is used to calculate irradiation-induced positron-emitter production in tissue for comparison with the +-activity measurement in order to infer indirect infor...

  5. Real-time dose compensation methods for scanned ion beam therapy of moving tumors

    International Nuclear Information System (INIS)

    Luechtenborg, Robert

    2012-01-01

    Scanned ion beam therapy provides highly tumor-conformal treatments. So far, only tumors showing no considerable motion during therapy have been treated as tumor motion and dynamic beam delivery interfere, causing dose deteriorations. One proposed technique to mitigate these deteriorations is beam tracking (BT), which adapts the beam position to the moving tumor. Despite application of BT, dose deviations can occur in the case of non-translational motion. In this work, real-time dose compensation combined with beam tracking (RDBT) has been implemented into the control system to compensate these dose changes by adaptation of nominal particle numbers during irradiation. Compared to BT, significantly reduced dose deviations were measured using RDBT. Treatment planning studies for lung cancer patients including the increased biological effectiveness of ions revealed a significantly reduced over-dose level (3/5 patients) as well as significantly improved dose homogeneity (4/5 patients) for RDBT. Based on these findings, real-time dose compensated re-scanning (RDRS) has been proposed that potentially supersedes the technically complex fast energy adaptation necessary for BT and RDBT. Significantly improved conformity compared to re-scanning, i.e., averaging of dose deviations by repeated irradiation, was measured in film irradiations. Simulations comparing RDRS to BT revealed reduced under- and overdoses of the former method.

  6. 48 CFR 52.222-32 - Davis-Bacon Act-Price Adjustment (Actual Method).

    Science.gov (United States)

    2010-10-01

    ... option to extend the term of the contract; or (2) Incorporation of a Davis-Bacon Act wage determination otherwise applied to the contract by operation of law. (d) Any adjustment will be limited to increases or... ACQUISITION REGULATION (CONTINUED) CLAUSES AND FORMS SOLICITATION PROVISIONS AND CONTRACT CLAUSES Text of...

  7. A novel suture method to place and adjust peripheral nerve catheters

    DEFF Research Database (Denmark)

    Rothe, C.; Steen-Hansen, C.; Madsen, M. H.

    2015-01-01

    We have developed a peripheral nerve catheter, attached to a needle, which works like an adjustable suture. We used in-plane ultrasound guidance to place 45 catheters close to the femoral, saphenous, sciatic and distal tibial nerves in cadaver legs. We displaced catheters after their initial...

  8. Fabrication of photonic crystals on several kinds of semiconductor materials by using focused-ion beam method

    International Nuclear Information System (INIS)

    Xu Xingsheng; Chen Hongda; Xiong Zhigang; Jin Aizi; Gu Changzhi; Cheng Bingying; Zhang Daozhong

    2007-01-01

    In this paper, we introduced the fabrication of photonic crystals on several kinds of semiconductor materials by using focused-ion beam machine, it shows that the method of focused-ion beam can fabricate two-dimensional photonic crystal and photonic crystal device efficiently, and the quality of the fabricated photonic crystal is high. Using the focused-ion beam method, we fabricate photonic crystal wavelength division multiplexer, and its characteristics are analyzed

  9. Characterization of strained InGaAs single quantum well structures by ion beam methods

    International Nuclear Information System (INIS)

    Yu, K.M.; Chan, K.T.

    1990-01-01

    We have investigated strained InGaAs single quantum well structures using MeV ion beam methods. The structural properties of these structures, including composition and well size, have been studied. It has been found that the composition obtained by Rutherford backscattering spectrometry and particle-induced x-ray emission techniques agrees very well with that obtained by the ion channeling method

  10. The method ADAMONT v1.0 for statistical adjustment of climate projections applicable to energy balance land surface models

    Directory of Open Access Journals (Sweden)

    D. Verfaillie

    2017-11-01

    Full Text Available We introduce the method ADAMONT v1.0 to adjust and disaggregate daily climate projections from a regional climate model (RCM using an observational dataset at hourly time resolution. The method uses a refined quantile mapping approach for statistical adjustment and an analogous method for sub-daily disaggregation. The method ultimately produces adjusted hourly time series of temperature, precipitation, wind speed, humidity, and short- and longwave radiation, which can in turn be used to force any energy balance land surface model. While the method is generic and can be employed for any appropriate observation time series, here we focus on the description and evaluation of the method in the French mountainous regions. The observational dataset used here is the SAFRAN meteorological reanalysis, which covers the entire French Alps split into 23 massifs, within which meteorological conditions are provided for several 300 m elevation bands. In order to evaluate the skills of the method itself, it is applied to the ALADIN-Climate v5 RCM using the ERA-Interim reanalysis as boundary conditions, for the time period from 1980 to 2010. Results of the ADAMONT method are compared to the SAFRAN reanalysis itself. Various evaluation criteria are used for temperature and precipitation but also snow depth, which is computed by the SURFEX/ISBA-Crocus model using the meteorological driving data from either the adjusted RCM data or the SAFRAN reanalysis itself. The evaluation addresses in particular the time transferability of the method (using various learning/application time periods, the impact of the RCM grid point selection procedure for each massif/altitude band configuration, and the intervariable consistency of the adjusted meteorological data generated by the method. Results show that the performance of the method is satisfactory, with similar or even better evaluation metrics than alternative methods. However, results for air temperature are generally

  11. The method ADAMONT v1.0 for statistical adjustment of climate projections applicable to energy balance land surface models

    Science.gov (United States)

    Verfaillie, Deborah; Déqué, Michel; Morin, Samuel; Lafaysse, Matthieu

    2017-11-01

    We introduce the method ADAMONT v1.0 to adjust and disaggregate daily climate projections from a regional climate model (RCM) using an observational dataset at hourly time resolution. The method uses a refined quantile mapping approach for statistical adjustment and an analogous method for sub-daily disaggregation. The method ultimately produces adjusted hourly time series of temperature, precipitation, wind speed, humidity, and short- and longwave radiation, which can in turn be used to force any energy balance land surface model. While the method is generic and can be employed for any appropriate observation time series, here we focus on the description and evaluation of the method in the French mountainous regions. The observational dataset used here is the SAFRAN meteorological reanalysis, which covers the entire French Alps split into 23 massifs, within which meteorological conditions are provided for several 300 m elevation bands. In order to evaluate the skills of the method itself, it is applied to the ALADIN-Climate v5 RCM using the ERA-Interim reanalysis as boundary conditions, for the time period from 1980 to 2010. Results of the ADAMONT method are compared to the SAFRAN reanalysis itself. Various evaluation criteria are used for temperature and precipitation but also snow depth, which is computed by the SURFEX/ISBA-Crocus model using the meteorological driving data from either the adjusted RCM data or the SAFRAN reanalysis itself. The evaluation addresses in particular the time transferability of the method (using various learning/application time periods), the impact of the RCM grid point selection procedure for each massif/altitude band configuration, and the intervariable consistency of the adjusted meteorological data generated by the method. Results show that the performance of the method is satisfactory, with similar or even better evaluation metrics than alternative methods. However, results for air temperature are generally better than for

  12. SU-E-T-626: Practical Method to Implement Arc Therapy Using Scanned Particle Beams

    Energy Technology Data Exchange (ETDEWEB)

    Eley, J; Mehta, M; Molitoris, J; Langner, U; Langen, K [University of Maryland School of Medicine, Baltimore, MD (United States)

    2015-06-15

    Purpose: The purpose of this study was to propose a method to implement arc therapy that is compatible with existing particle therapy systems having gantries and pencil-beam scanning capacities. Furthermore, we sought to demonstrate expected benefits of this method for selected clival chordoma patients. Methods: We propose that a desired particle arc treatment plan can be discretized into a finite number of fixed beams and that only one (or a subset) of these beams be delivered in any single treatment fraction; the target should receive uniform dose during each fraction. For 3 clival-chordoma patients, robust-optimized, scanned proton beams were simulated to deliver 78 Gy (RBE) to clinical target volumes (CTVs), using either a single-field plan with a posterior-anterior (PA) beam or a discrete-arc plan with 16 beams that were equally spaced throughout a 360-degree axial arc. Dose-volume metrics were compared with emphasis on the brainstem, since risk of radiation necrosis there can often restrict application of tumoricidal doses for chordomas. Results: The mean volume of brainstem receiving a dose of 60 Gy (RBE) or higher (V60Gy) was 10.3±0.9 cm{sup 3} for the single-field plan and 4.7±1.8 cm{sup 3} for the discrete-arc plan, a reduction of 55% in favor of arcs. The mean dose to the brainstem was also reduced using arcs, by 18%, while the maximum dose was nearly identical for both methods. For the whole brain, V60Gy was reduced by 23%, in favor of arcs. Mean dose to the CTVs were nearly identical for both strategies, within 0.3%. Conclusion: Discrete arc treatments can be implemented using existing scanned particle-beam facilities. Aside from the physical advantages, the biological uncertainties of particle therapy, particularly high in the distal edge, can be reduced by arc therapy via rotational smearing, which may be of benefit for tumors near the brainstem.

  13. Coordinate transformation based cryo-correlative methods for electron tomography and focused ion beam milling

    International Nuclear Information System (INIS)

    Fukuda, Yoshiyuki; Schrod, Nikolas; Schaffer, Miroslava; Feng, Li Rebekah; Baumeister, Wolfgang; Lucic, Vladan

    2014-01-01

    Correlative microscopy allows imaging of the same feature over multiple length scales, combining light microscopy with high resolution information provided by electron microscopy. We demonstrate two procedures for coordinate transformation based correlative microscopy of vitrified biological samples applicable to different imaging modes. The first procedure aims at navigating cryo-electron tomography to cellular regions identified by fluorescent labels. The second procedure, allowing navigation of focused ion beam milling to fluorescently labeled molecules, is based on the introduction of an intermediate scanning electron microscopy imaging step to overcome the large difference between cryo-light microscopy and focused ion beam imaging modes. These methods make it possible to image fluorescently labeled macromolecular complexes in their natural environments by cryo-electron tomography, while minimizing exposure to the electron beam during the search for features of interest. - Highlights: • Correlative light microscopy and focused ion beam milling of vitrified samples. • Coordinate transformation based cryo-correlative method. • Improved correlative light microscopy and cryo-electron tomography

  14. Beam-Based Error Identification and Correction Methods for Particle Accelerators

    CERN Document Server

    AUTHOR|(SzGeCERN)692826; Tomas, Rogelio; Nilsson, Thomas

    2014-06-10

    Modern particle accelerators have tight tolerances on the acceptable deviation from their desired machine parameters. The control of the parameters is of crucial importance for safe machine operation and performance. This thesis focuses on beam-based methods and algorithms to identify and correct errors in particle accelerators. The optics measurements and corrections of the Large Hadron Collider (LHC), which resulted in an unprecedented low β-beat for a hadron collider is described. The transverse coupling is another parameter which is of importance to control. Improvement in the reconstruction of the coupling from turn-by-turn data has resulted in a significant decrease of the measurement uncertainty. An automatic coupling correction method, which is based on the injected beam oscillations, has been successfully used in normal operation of the LHC. Furthermore, a new method to measure and correct chromatic coupling that was applied to the LHC, is described. It resulted in a decrease of the chromatic coupli...

  15. SU-F-T-176: Therapeutic Proton Beam Range Measurement Method with EBT3 Film

    Energy Technology Data Exchange (ETDEWEB)

    Lee, N [National Cancer Center, Goyang-si, Gyeonggi-do (Korea, Republic of)

    2016-06-15

    Purpose: Ocular proton therapy has the following advantages: i) sparing optic nerve, ii) the minimal dose is delivered to surrounding normal tissues. Since the proton therapy center was opened in 2007, 30 patients with ocular tumor have been treated at National Cancer Center using single scattering technique. To develop a solid eye phantom which can verify the output and the beam range with EBT3 film for independent patient QA in ocular proton therapy. Methods: The proton therapy is very effective to treat ocular tumor, because of the Bragg peak feature. In general, the beam shape of eye treatment is about 3 cm in diameter and the beam range is under 5 cm. However, proton therapy has uncertainty of beam range problem due to various stopping power of normal tissue, bone, air and so on, so that we should verify the beam range before treatment. For this purpose, a new PMMA phantom with wedge has been developed to use the film dosimetry and the ionization chamber. It is able to place a film on the slope of the phantom, which the spread out Bragg Peak by the water equivalent thickness value of PMMA can be made on the film. We considered to relation with quenching effect of proton energy and range for simple second check. In addition, the ionization chamber (Pin-point chamber, PTW 31014) can be inserted into a hole in the phantom to measure the absolute dose. Results: The output difference and beam range difference were less than 2% and 1.0 mm, respectively, between the measurement and the plan. Conclusion: An eye phantom was developed and its performance was evaluated successfully and it was useful to verify the output. Also with EBT3 film with the quenching effect for measurement depth-dose profile, range to patient QA.

  16. A Water Hammer Protection Method for Mine Drainage System Based on Velocity Adjustment of Hydraulic Control Valve

    Directory of Open Access Journals (Sweden)

    Yanfei Kou

    2016-01-01

    Full Text Available Water hammer analysis is a fundamental work of pipeline systems design process for water distribution networks. The main characteristics for mine drainage system are the limited space and high cost of equipment and pipeline changing. In order to solve the protection problem of valve-closing water hammer for mine drainage system, a water hammer protection method for mine drainage system based on velocity adjustment of HCV (Hydraulic Control Valve is proposed in this paper. The mathematic model of water hammer fluctuations is established based on the characteristic line method. Then, boundary conditions of water hammer controlling for mine drainage system are determined and its simplex model is established. The optimization adjustment strategy is solved from the mathematic model of multistage valve-closing. Taking a mine drainage system as an example, compared results between simulations and experiments show that the proposed method and the optimized valve-closing strategy are effective.

  17. Assimilation of satellite cloud data into the DAO finite volume Data Assimilation System using a parameter adjustment method

    Science.gov (United States)

    Norris, P.; da Silva, A.

    2003-04-01

    Cloud fraction and optical depth data from the International Satellite Cloud Climatology Project (ISCCP) and cloud liquid water path retrievals from the Special Sensor Microwave/Imager (SSM/I) instrument are assimilated into the NASA Data Assimilation Office finite volume Data Assimilation System (fvDAS) using a parameter adjustment method. The rationale behind this adjustment method is that there are several empirical parameters in the model cloud/radiation parameterizations (e.g., ``critical relative humidity'') that are not in-fact universal but have remaining spatial and temporal dependencies. These parameters can be slowly adjusted in space and time to improve the model's representation of cloud properties. In this study, the Slingo-type relative-humidity-based diagnostic cloud fraction of the Community Climate Model (CCM3) is generalized to a two parameter S-shaped dependence of cloud fraction on relative humidity. These two parameters are adjusted in both low and mid-high cloud bands using observed cloud fractions in these bands derived from ISCCP DX data. This procedure greatly improves the representation of cloud fraction in the model as compared with ISCCP data. It also significantly improves mid-latitude longwave cloud radiative forcing, as independently validated against Clouds and the Earth's Radiant Energy System (CERES) data, and mid-latitude column-averaged liquid water path (LWP) over ocean, as validated against TRMM Microwave Imager (TMI) data. The cloud fraction assimilation, by itself, degrades the shortwave cloud radiative forcing at the top-of-atmosphere, but this is recovered (as validated against CERES) by assimilating SSM/I LWP and ISCCP optical depth data via adjustment of the CCM3 diagnostic cloud liquid water parameterization and the dependence of the CCM3 column optical depth on layer cloud fractions. The net effect of this promising cloud data assimilation method is to improve forecast skill for cloud cover and optical depth. Other

  18. Practical assessment of magnetic methods for corrosion detection in an adjacent precast, prestressed concrete box-beam bridge

    Science.gov (United States)

    Fernandes, Bertrand; Titus, Michael; Nims, Douglas Karl; Ghorbanpoor, Al; Devabhaktuni, Vijay Kumar

    2013-06-01

    Magnetic methods are progressing in the detection of corrosion in prestressing strands in adjacent precast, prestressed concrete box-beam bridges. This study is the first field trial of magnetic strand defect detection systems on an adjacent box-beam bridge. A bridge in Fayette County, Ohio, which was scheduled for demolition, was inspected. Damage to prestressed box-beams is often due to corrosion of the prestressing strands. The corroded strands show discontinuities and a reduced cross-sectional area. These changes, due to corrosion, are reflected in the magnetic signatures of the prestressing steel. Corrosion in the prestressing steel was detected using two magnetic methods, namely the 'magnetic flux leakage' (MFL) and the 'induced magnetic field'. The purpose of these tests was to demonstrate the ability of the magnetic methods to detect hidden corrosion in box-beams in the field and tackle the logistic problem of inspecting box-beams from the bottom. The inspections were validated by dissecting the bottom of the box-beams after the inspections. The results showed that the MFL method can detect hidden corrosion and strand breaks. Both magnetic field methods were also able to estimate corrosion by detecting the effective cross-sectional area of the strand in sections of the beams. Thus, it was shown that the magnetic methods can be used to predict hidden corrosion in prestressing strands of box-beams.

  19. Gaussian-to-top-hat beam shaping: an overview of parameters, methods, and applications

    Science.gov (United States)

    Homburg, O.; Mitra, T.

    2012-02-01

    Direct laser patterning of various materials is today widely used in several micro-system production lines like inkjet printing, solar cell technology, flat-panel display production, LEDs, OLEDs, semiconductors and medicine. Typically single-mode solid state lasers and their higher harmonics (e. g. 266, 355, 532 and 1064 nm) are used especially for machining of holes and grooves. The striking advantages of flat top intensity distributions compared to Gaussian beam profiles with respect to the efficiency and quality of these processes were already demonstrated. Here we will give an overview of parameters, methods and applications of Gaussian-to-top-hat beam shaping. The top hat field size can start from about 30 μm with no upper size limitation in the far field of the optics. Beam shaping for various wavelengths were realized with field geometries of squares, rectangles and circles. With LIMO's compact Gaussian-to-top-hat converter an inhomogeneity better than 5% contrast was reached. Special focus is put on the integration of Gaussian-to-top-hat beam shapers in fast scanning systems employing Galvo mirrors and a specially developed f-Theta lens to avoid destruction of the top hat profile within the scan field. Results with a 50x50μm2 top hat size (inhomogeneity down to solar panels.

  20. Damage Detection of Axially Loaded Beam: A Frequency-Based Method

    Directory of Open Access Journals (Sweden)

    Omid Rezaifar

    2016-06-01

    Full Text Available The present study utilizes an analytical method to formulate the three lowest modal frequencies of axially-loaded notched beam through both crack location and load level in a specific format that can be used in existing frequency-based crack-identification methods. The proposed formula provides a basis to shift into two states, one with axial loading and the other without any loading whatsoever. When any two natural frequencies in simply-supported beam with an open crack, subjected to axial load, are measured, crack position and extent can be determined, using a characteristic equation, which is a function of crack location, sectional flexibility, and eigenvalue (natural frequency. Theoretical results show high accuracy for service axial loads. In this range, errors for crack location and extent are less than 12% and 10%, respectively.

  1. SU-F-E-19: A Novel Method for TrueBeam Jaw Calibration

    Energy Technology Data Exchange (ETDEWEB)

    Corns, R; Zhao, Y; Huang, V [Fraser Valley Cancer Centre - BC Cancer Agency, Surrey, BC (United Kingdom)

    2016-06-15

    Purpose: A simple jaw calibration method is proposed for Varian TrueBeam using an EPID-Encoder combination that gives accurate fields sizes and a homogeneous junction dose. This benefits clinical applications such as mono-isocentric half-beam block breast cancer or head and neck cancer treatment with junction/field matching. Methods: We use EPID imager with pixel size 0.392 mm × 0.392 mm to determine the radiation jaw position as measured from radio-opaque markers aligned with the crosshair. We acquire two images with different symmetric field sizes and record each individual jaw encoder values. A linear relationship between each jaw’s position and its encoder value is established, from which we predict the encoder values that produce the jaw positions required by TrueBeam’s calibration procedure. During TrueBeam’s jaw calibration procedure, we move the jaw with the pendant to set the jaw into position using the predicted encoder value. The overall accuracy is under 0.1 mm. Results: Our in-house software analyses images and provides sub-pixel accuracy to determine field centre and radiation edges (50% dose of the profile). We verified the TrueBeam encoder provides a reliable linear relationship for each individual jaw position (R{sup 2}>0.9999) from which the encoder values necessary to set jaw calibration points (1 cm and 19 cm) are predicted. Junction matching dose inhomogeneities were improved from >±20% to <±6% using this new calibration protocol. However, one technical challenge exists for junction matching, if the collimator walkout is large. Conclusion: Our new TrueBeam jaw calibration method can systematically calibrate the jaws to crosshair within sub-pixel accuracy and provides both good junction doses and field sizes. This method does not compensate for a larger collimator walkout, but can be used as the underlying foundation for addressing the walkout issue.

  2. Method of middle-intensive electron beams diagnostics by means of transient radiation

    Directory of Open Access Journals (Sweden)

    Vorobyov G. S.

    2010-10-01

    Full Text Available The general method of diagnostics of transient radiation of ribbon-shaped and axially-symmetric electron beams of small section and high power density is described. A comparative analysis of different types of receivers of a transient radiation is carried out for the first time. Advantages and disadvantages of each of receivers of radiation, which must be taken into account at the analysis of concrete object of researches, are indicated.

  3. An improved finite-difference beam propagation method and its application in arrayed waveguide grating

    Science.gov (United States)

    Liu, Xin; Liu, De-ming; Wu, Wei

    2008-11-01

    Finite-Difference Beam Propagation Method (FD-BPM) in conventional is modified, according to more accurate Helmholtz equation, a new arithmetic is advanced. By using the new arithmetic and the old arithmetic in calculating slab waveguide and calculate the parameter which scales the precision of the method and the calculating time, we prove that the accuracy of the new arithmetic is improved without affecting time performance. At last we calculate the transmission mode in the AWG by the new method to show the practical value of the modified arithmetic.

  4. Splitting of high power, cw proton beams

    Directory of Open Access Journals (Sweden)

    Alberto Facco

    2007-09-01

    Full Text Available A simple method for splitting a high power, continuous wave (cw proton beam in two or more branches with low losses has been developed in the framework of the EURISOL (European Isotope Separation On-Line Radioactive Ion Beam Facility design study. The aim of the system is to deliver up to 4 MW of H^{-} beam to the main radioactive ion beam production target, and up to 100 kW of proton beams to three more targets, simultaneously. A three-step method is used, which includes magnetic neutralization of a fraction of the main H^{-} beam, magnetic splitting of H^{-} and H^{0}, and stripping of H^{0} to H^{+}. The method allows slow raising and individual fine adjustment of the beam intensity in each branch.

  5. Inspection Mechanism and Experimental Study of Prestressed Reverse Tension Method under PC Beam Bridge Anchorage

    Science.gov (United States)

    Peng, Zhang

    2018-03-01

    the prestress under anchorage is directly related to the structural security and performance of PC beam bridge. The reverse tension method is a kind of inspection which confirms the prestress by exerting reversed tension load on the exposed prestressing tendon of beam bridge anchoring system. The thesis elaborately expounds the inspection mechanism and mechanical effect of reverse tension method, theoretically analyzes the influential elements of inspection like tool anchorage deformation, compression of conjuncture, device glide, friction of anchorage loop mouth and elastic compression of concrete, and then presents the following formula to calculate prestress under anchorage. On the basis of model experiment, the thesis systematically studies some key issues during the reverse tension process of PC beam bridge anchorage system like the formation of stress-elongation curve, influential factors, judgment method of prestress under anchorage, variation trend and compensation scale, verifies the accuracy of mechanism analysis and demonstrates: the prestress under anchorage is less than or equal to 75% of the ultimate strength of prestressing tendon, the error of inspect result is less than 1%, which can meet with the demands of construction. The research result has provided theoretical basis and technical foundation for the promotion and application of reverse tension in bridge construction.

  6. Beam transient analyses of Accelerator Driven Subcritical Reactors based on neutron transport method

    Energy Technology Data Exchange (ETDEWEB)

    He, Mingtao; Wu, Hongchun [School of Nuclear Science and Technology, Xi’an Jiaotong University, Xi’an 710049, Shaanxi (China); Zheng, Youqi, E-mail: yqzheng@mail.xjtu.edu.cn [School of Nuclear Science and Technology, Xi’an Jiaotong University, Xi’an 710049, Shaanxi (China); Wang, Kunpeng [Nuclear and Radiation Safety Center, PO Box 8088, Beijing 100082 (China); Li, Xunzhao; Zhou, Shengcheng [School of Nuclear Science and Technology, Xi’an Jiaotong University, Xi’an 710049, Shaanxi (China)

    2015-12-15

    Highlights: • A transport-based kinetics code for Accelerator Driven Subcritical Reactors is developed. • The performance of different kinetics methods adapted to the ADSR is investigated. • The impacts of neutronic parameters deteriorating with fuel depletion are investigated. - Abstract: The Accelerator Driven Subcritical Reactor (ADSR) is almost external source dominated since there is no additional reactivity control mechanism in most designs. This paper focuses on beam-induced transients with an in-house developed dynamic analysis code. The performance of different kinetics methods adapted to the ADSR is investigated, including the point kinetics approximation and space–time kinetics methods. Then, the transient responds of beam trip and beam overpower are calculated and analyzed for an ADSR design dedicated for minor actinides transmutation. The impacts of some safety-related neutronics parameters deteriorating with fuel depletion are also investigated. The results show that the power distribution varying with burnup leads to large differences in temperature responds during transients, while the impacts of kinetic parameters and feedback coefficients are not very obvious. Classification: Core physic.

  7. Target-ion source unit ionization efficiency measurement by method of stable ion beam implantation

    CERN Document Server

    Panteleev, V.N; Fedorov, D.V; Moroz, F.V; Orlov, S.Yu; Volkov, Yu.M

    The ionization efficiency is one of the most important parameters of an on-line used target-ion source system exploited for production of exotic radioactive beams. The ionization efficiency value determination as a characteristic of a target-ion source unit in the stage of its normalizing before on-line use is a very important step in the course of the preparation for an on-line experiment. At the IRIS facility (Petersburg Nuclear Physics Institute, Gatchina) a reliable and rather precise method of the target-ion source unit ionization efficiency measurement by the method of stable beam implantation has been developed. The method worked out exploits an off-line mass-separator for the implantation of the ion beams of selected stable isotopes of different elements into a tantalum foil placed inside the Faraday cup in the focal plane of the mass-separator. The amount of implanted ions has been measured with a high accuracy by the current integrator connected to the Faraday cup. After the implantation of needed a...

  8. System and method of adjusting the equilibrium temperature of an inductively-heated susceptor

    Science.gov (United States)

    Matsen, Marc R; Negley, Mark A; Geren, William Preston

    2015-02-24

    A system for inductively heating a workpiece may include an induction coil, at least one susceptor face sheet, and a current controller coupled. The induction coil may be configured to conduct an alternating current and generate a magnetic field in response to the alternating current. The susceptor face sheet may be configured to have a workpiece positioned therewith. The susceptor face sheet may be formed of a ferromagnetic alloy having a Curie temperature and being inductively heatable to an equilibrium temperature approaching the Curie temperature in response to the magnetic field. The current controller may be coupled to the induction coil and may be configured to adjust the alternating current in a manner causing a change in at least one heating parameter of the susceptor face sheet.

  9. Method for optimum determination of adjustable parameters in the boiling water reactor core simulator using operating data on flux distribution

    International Nuclear Information System (INIS)

    Kiguchi, T.; Kawai, T.

    1975-01-01

    A method has been developed to optimally and automatically determine the adjustable parameters of the boiling water reactor three-dimensional core simulator FLARE. The steepest gradient method is adopted for the optimization. The parameters are adjusted to best fit the operating data on power distribution measured by traversing in-core probes (TIP). The average error in the calculated TIP readings normalized by the core average is 0.053 at the rated power. The k-infinity correction term has also been derived theoretically to reduce the relatively large error in the calculated TIP readings near the tips of control rods, which is induced by the coarseness of mesh points. By introducing this correction, the average error decreases to 0.047. The void-quality relation is recognized as a function of coolant flow rate. The relation is estimated to fit the measured distributions of TIP reading at the partial power states

  10. Weight-adjusted discontinuous Galerkin methods: Matrix-valued weights and elastic wave propagation in heterogeneous media

    Science.gov (United States)

    Chan, Jesse

    2018-03-01

    Weight-adjusted inner products are easily invertible approximations to weighted $L^2$ inner products. These approximations can be paired with a discontinuous Galerkin (DG) discretization to produce a time-domain method for wave propagation which is low storage, energy stable, and high order accurate for arbitrary heterogeneous media and curvilinear meshes. In this work, we extend weight-adjusted DG (WADG) methods to the case of matrix-valued weights, with the linear elastic wave equation as an application. We present a DG formulation of the symmetric form of the linear elastic wave equation, with upwind-like dissipation incorporated through simple penalty fluxes. A semi-discrete convergence analysis is given, and numerical results confirm the stability and high order accuracy of WADG for several problems in elastic wave propagation.

  11. Adjusting for treatment switching in randomised controlled trials - A simulation study and a simplified two-stage method.

    Science.gov (United States)

    Latimer, Nicholas R; Abrams, K R; Lambert, P C; Crowther, M J; Wailoo, A J; Morden, J P; Akehurst, R L; Campbell, M J

    2017-04-01

    Estimates of the overall survival benefit of new cancer treatments are often confounded by treatment switching in randomised controlled trials (RCTs) - whereby patients randomised to the control group are permitted to switch onto the experimental treatment upon disease progression. In health technology assessment, estimates of the unconfounded overall survival benefit associated with the new treatment are needed. Several switching adjustment methods have been advocated in the literature, some of which have been used in health technology assessment. However, it is unclear which methods are likely to produce least bias in realistic RCT-based scenarios. We simulated RCTs in which switching, associated with patient prognosis, was permitted. Treatment effect size and time dependency, switching proportions and disease severity were varied across scenarios. We assessed the performance of alternative adjustment methods based upon bias, coverage and mean squared error, related to the estimation of true restricted mean survival in the absence of switching in the control group. We found that when the treatment effect was not time-dependent, rank preserving structural failure time models (RPSFTM) and iterative parameter estimation methods produced low levels of bias. However, in the presence of a time-dependent treatment effect, these methods produced higher levels of bias, similar to those produced by an inverse probability of censoring weights method. The inverse probability of censoring weights and structural nested models produced high levels of bias when switching proportions exceeded 85%. A simplified two-stage Weibull method produced low bias across all scenarios and provided the treatment switching mechanism is suitable, represents an appropriate adjustment method.

  12. Development and Testing of a Decision Making Based Method to Adjust Automatically the Harrowing Intensity

    Directory of Open Access Journals (Sweden)

    Roland Gerhards

    2013-05-01

    Full Text Available Harrowing is often used to reduce weed competition, generally using a constant intensity across a whole field. The efficacy of weed harrowing in wheat and barley can be optimized, if site-specific conditions of soil, weed infestation and crop growth stage are taken into account. This study aimed to develop and test an algorithm to automatically adjust the harrowing intensity by varying the tine angle and number of passes. The field variability of crop leaf cover, weed density and soil density was acquired with geo-referenced sensors to investigate the harrowing selectivity and crop recovery. Crop leaf cover and weed density were assessed using bispectral cameras through differential images analysis. The draught force of the soil opposite to the direction of travel was measured with electronic load cell sensor connected to a rigid tine mounted in front of the harrow. Optimal harrowing intensity levels were derived in previously implemented experiments, based on the weed control efficacy and yield gain. The assessments of crop leaf cover, weed density and soil density were combined via rules with the aforementioned optimal intensities, in a linguistic fuzzy inference system (LFIS. The system was evaluated in two field experiments that compared constant intensities with variable intensities inferred by the system. A higher weed density reduction could be achieved when the harrowing intensity was not kept constant along the cultivated plot. Varying the intensity tended to reduce the crop leaf cover, though slightly improving crop yield. A real-time intensity adjustment with this system is achievable, if the cameras are attached in the front and at the rear or sides of the harrow.

  13. Reduction of system matrices of planar beam in ANCF by component mode synthesis method

    International Nuclear Information System (INIS)

    Kobayashi, Nobuyuki; Wago, Tsubasa; Sugawara, Yoshiki

    2011-01-01

    A method of reducing the system matrices of a planar flexible beam described by an absolute nodal coordinate formulation (ANCF) is presented. In this method, we focus that the bending stiffness matrix expressed by adopting a continuum mechanics approach to the ANCF beam element is constant when the axial strain is not very large. This feature allows to apply the Craig–Bampton method to the equation of motion that is composed of the independent coordinates when the constraint forces are eliminated. Four numerical examples that compare the proposed method and the conventional ANCF are demonstrated to verify the performance and accuracy of the proposed method. From these examples, it is verified that the proposed method can describe the large deformation effects such as dynamic stiffening due to the centrifugal force, as well as the conventional ANCF does. The use of this method also reduces the computing time, while maintaining an acceptable degree of accuracy for the expression characteristics of the conventional ANCF when the modal truncation number is adequately employed. This reduction in CPU time particularly pronounced in the case of a large element number and small modal truncation number; the reduction can be verified not only in the case of small deformation but also in the case of a fair bit large deformation.

  14. Propagation of low-quality laser beams in turbulent air: new fast simulation methods and experimental results

    Science.gov (United States)

    Hall, Thomas; Spindler, Gerhard; Becker, Peter; Grünewald, Karin; Pargmann, Carsten; Duschek, Frank

    2017-11-01

    Novel inherently fast methods basing upon fundamental Gaussian modes are presented to numerically simulate the propagation behavior of a low-quality laser beam, i.e., a beam characterized by a high quality factor M^2, in turbulent air. Actually, for a given initial diameter, beam wandering and spread at the target position is calculated. Test results are checked against respective simulations using higher-order mode beams having clearly defined quality factors and nearly perfect agreement is demonstrated. Experiments performed on the German Aerospace Center (DLR) laser test range at Lampoldshausen near Stuttgart satisfactorily accord with the predictions of the proposed simulation techniques.

  15. Business Management Adjusting - an integrated method to optimize business workflow. Holistic, flexible control systems; Business Management Adjusting - ein integrierter Ansatz. Ganzheitliches, flexibles Steuerungssystem

    Energy Technology Data Exchange (ETDEWEB)

    Wiedmann, K.P. [Hannover Univ. (Germany). Fachbereich Wirtschaftswissenschaften; Schlichting, R. [Isuma Consulting GmbH, Mannheim (Germany)

    2002-04-08

    The fields associated with energy supply companies change much faster. Constant changes are required for successful participation in market events. With business management adjusting (BMA), service companies receive effective instruments for the constant optimisation of their commercial processes. BMA processes in several places in the organization simultaneously. By providing management objectives and numerous options for fine adjustment, upper level managements acquires an intelligent control system. Companies-specific needs and the experiences of the employees are constantly being considered. (orig.) [German] Das Umfeld der Energieversorgungsunternehmen aendert sich immer schneller. Fuer eine erfolgreiche Teilnahme am Marktgeschehen sind stetige Veraenderungen erforderlich. Mit business management adjusting (BMA) bekommen Dienstleistungsunternehmen ein wirksames Instrumentarium zur stetigen Optimierung ihrer Geschaeftsprozesse. Dabei setzt BMA an mehreren Stellen gleichzeitig an. Durch Zielsetzungen und zahlreiche Moeglichkeiten der Feinjustierung erhalten die Fuehrungsebenen ein >>sich selbst immer weiter schaerfendes Steuerungssystem<<. Unternehmensspezifische Besonderheiten und die Erfahrungen der Mitarbeiter werden konsequent beruecksichtigt. (orig.)

  16. A novel method for megavoltage scatter correction in cone-beam CT acquired concurrent with rotational irradiation

    NARCIS (Netherlands)

    van Herk, Marcel; Ploeger, Lennert; Sonke, Jan-Jakob

    2011-01-01

    Acquisition of cone-beam CT (CBCT) concurrent with VMAT results in scatter of the megavoltage (MV) beam onto the kilovoltage (kV) detector deteriorating CBCT image quality. The aim of this paper is to develop a method to estimate and correct for MV scatter reaching the kV panel. The correction

  17. The Adjusted Net Asset Valuation Method – Connecting the dots between Theory and Practice

    Directory of Open Access Journals (Sweden)

    Silvia Ghiță-Mitrescu

    2016-01-01

    The goal of this paper is to present the theoretical background of this method as well as itspractical application. We will first analyze the main theoretical issues regarding the correctionsthat need to be performed in order to transform the book value of assets and liabilities to theirmarket value, afterwards proceeding to an example on how this method is applied to the balancesheet of a company. Finally, we will conclude on the importance of the method for a company’sevaluation process.

  18. A new method of measurement of trace elements by using particle beams

    International Nuclear Information System (INIS)

    Matsumoto, Shinji

    1982-01-01

    A new method of measurement of light elements by using the particle beam from an accelerator was developed. This paper reports on the results of analyses of N-15 and O-18. The tandem accelerator of University of Tokyo was used to accelerate proton beam. The energy of protons was determined from the excitation curves of elastic scattering by N-15, O-18 and O-16. The scattering by O-16 was background count. Therefore, The measurement was made at the energy of small background and large true counting. Biological samples were examined. The linearity of counts with the concentration of N-15 and O-18 was confirmed. The cells which contain glycine (O-18, 71.8 percent) and methionine (N-15, 95 percent) were analyzed. The peaks of N-15 and O-18 were well separated from teh peaks by N-14 and O-16. The natural amounts of N-15 in adenine and O-18 in glucose were also measured. The resonance reaction method of measurement by using particle beam was developed. (Kato, T.)

  19. An evaluation of the sandwich beam compression test method for composites

    Science.gov (United States)

    Shuart, M. J.

    1981-01-01

    The sandwich beam in a four-point bending compressive test method for advanced composites is evaluated. Young's modulus and Poisson's ratio were obtained for graphite/polyimide beam specimens tested at 117 K, room temperature, and 589 K. Tensile elastic properties obtained from the specimens were assumed to be equal to the compressive elastic properties and were used in the analysis. Strain gages were used to record strain data. A three-dimensional finite-element model was used to examine the effects of the honeycomb core on measured composite mechanical properties. Results of the analysis led to the following conclusions: (1) a near uniaxial compressive stress state existed in the top cover and essentially all the compressive load was carried by the top cover; (2) laminate orientation, test temperature, and type of honeycomb core material were shown to affect the type of beam failure; and (3) the test method can be used to obtain compressive elastic constants over the temperature range 117 to 589 K.

  20. New Density Estimation Methods for Charged Particle Beams With Applications to Microbunching Instability

    Energy Technology Data Exchange (ETDEWEB)

    Balsa Terzic, Gabriele Bassi

    2011-07-01

    In this paper we discuss representations of charge particle densities in particle-in-cell (PIC) simulations, analyze the sources and profiles of the intrinsic numerical noise, and present efficient methods for their removal. We devise two alternative estimation methods for charged particle distribution which represent significant improvement over the Monte Carlo cosine expansion used in the 2d code of Bassi, designed to simulate coherent synchrotron radiation (CSR) in charged particle beams. The improvement is achieved by employing an alternative beam density estimation to the Monte Carlo cosine expansion. The representation is first binned onto a finite grid, after which two grid-based methods are employed to approximate particle distributions: (i) truncated fast cosine transform (TFCT); and (ii) thresholded wavelet transform (TWT). We demonstrate that these alternative methods represent a staggering upgrade over the original Monte Carlo cosine expansion in terms of efficiency, while the TWT approximation also provides an appreciable improvement in accuracy. The improvement in accuracy comes from a judicious removal of the numerical noise enabled by the wavelet formulation. The TWT method is then integrated into Bassi's CSR code, and benchmarked against the original version. We show that the new density estimation method provides a superior performance in terms of efficiency and spatial resolution, thus enabling high-fidelity simulations of CSR effects, including microbunching instability.

  1. Study of corrosion behavior of carbon steel under seawater film using the wire beam electrode method

    International Nuclear Information System (INIS)

    Liu, Zaijian; Wang, Wei; Wang, Jia; Peng, Xin; Wang, Yanhua; Zhang, Penghui; Wang, Haijie; Gao, Congjie

    2014-01-01

    Corrosion behavior of carbon steel under seawater film with various thickness was investigated by the wire beam electrode (WBE) method. It was found that the corrosion rate of carbon steel increased significantly under thin seawater film than it was immersed in seawater. The current variation under seawater film indicated that the thickness of diffusion layer of oxygen was about 500 μm, and the maximal current appeared around 40 μm, at which corrosion rate transited from cathodic control to anodic control. The results suggest that WBE method is helpful to study the corrosion process under thin electrolyte film

  2. A Self-Adjusting Method to Resist Bus Bunching Based on Boarding Limits

    Directory of Open Access Journals (Sweden)

    Shuzhi Zhao

    2016-01-01

    Full Text Available Bus bunching is one of the most serious problems of urban bus systems. Bus bunching increases waiting and travel time of passengers. Many bus systems use schedules to reach equal headways. Compared to the idea of schedules and the target headway introduced later, we propose a new method to improve the efficiency of a bus system and avoid bus bunching by boarding limits. Our solution can be effectively implemented when buses cannot travel as planned because of bad road conditions and dynamic demands at bus stops. Besides, using our method, bus headways reach the state with equal headways dynamically and spontaneously without drivers’ explicit intervention. Moreover, the method can improve the level of the bus service and reduce total travel time of passengers. We verify our method using an ideal bus route and a real bus route, both showing the success of the proposed method.

  3. Determination of the total neutron cross section using average energy shift method for filtered neutron beam

    Directory of Open Access Journals (Sweden)

    О. О. Gritzay

    2016-12-01

    Full Text Available Development of the technique for determination of the total neutron cross sections from the measurements of sample transmission by filtered neutrons, scattered on hydrogen is described. One of the methods of the transmission determination TH52Cr from the measurements of 52Cr sample, using average energy shift method for filtered neutron beam is presented. Using two methods of the experimental data processing, one of which is presented in this paper (another in [1], there is presented a set of transmissions, obtained for different samples and for different measurement angles. Two methods are fundamentally different; therefore, we can consider the obtained processing results, using these methods as independent. In future, obtained set of transmissions is planned to be used for determination of the parameters E0, Гn and R/ of the resonance 52Cr at the energy of 50 keV.

  4. A method of mounting multiple otoliths for beam-based microchemical analyses

    Science.gov (United States)

    Donohoe, C.J.; Zimmerman, C.E.

    2010-01-01

    Beam-based analytical methods are widely used to measure the concentrations of elements and isotopes in otoliths. These methods usually require that otoliths be individually mounted and prepared to properly expose the desired growth region to the analytical beam. Most analytical instruments, such as LA-ICPMS and ion and electron microprobes, have sample holders that will accept only one to six slides or mounts at a time. We describe a method of mounting otoliths that allows for easy transfer of many otoliths to a single mount after they have been prepared. Such an approach increases the number of otoliths that can be analyzed in a single session by reducing the need open the sample chamber to exchange slides-a particularly time consuming step on instruments that operate under vacuum. For ion and electron microprobes, the method also greatly reduces the number of slides that must be coated with an electrical conductor prior to analysis. In this method, a narrow strip of cover glass is first glued at one end to a standard microscope slide. The otolith is then mounted in thermoplastic resin on the opposite, free end of the strip. The otolith can then be ground and flipped, if needed, by reheating the mounting medium. After otolith preparation is complete, the cover glass is cut with a scribe to free the otolith and up to 20 small otoliths can be arranged on a single petrographic slide. ?? 2010 The Author(s).

  5. An analytical geometric calibration method for circular cone-beam geometry.

    Science.gov (United States)

    Xu, Jingyan; Tsui, Benjamin M W

    2013-09-01

    This work is a continuation of our previous work on geometric calibration in the circular cone-beam geometry. It is well known that seven parameters completely describe such a geometry in either flat-panel X-ray computed tomography or single pinhole SPECT imaging. Previously we developed a graphical procedure to determine the detector in-plane rotation angle independently of the other six parameters. Using the discovered geometrical relationships, in this paper we determine the remaining six parameters using the cone-beam projections of a minimum of three point objects. Our method is analytical. It makes use of the parameters of the fitted ellipse from the calibration data. The parameter estimation is accurate in the noise-free case or when there is moderate projection data truncation or shorter calibration scan range ( ≤ 360°). We perform numerical evaluations to study the robustness of the proposed method under different projection noise levels and using different data acquisition ranges. Using a full 360° scan range, the estimation accuracy and precision of our method are comparable or superior to previous methods. Using a shorter acquisition range, there may be bias in the ellipse parameters obtained by simple algebraic fitting methods. This bias will propagate to the estimated geometric parameters. Such bias can be mostly eliminated by using a more sophisticated fitting algorithm. At the same noise level, the geometric parameter estimation accuracies are comparable, but the estimation precision degrades, as the acquisition range becomes shorter.

  6. Kinetic methods for measuring the temperature of clusters and nanoparticles in molecular beams

    International Nuclear Information System (INIS)

    Makarov, Grigorii N

    2011-01-01

    The temperature (internal energy) of clusters and nanoparticles is an important physical parameter which affects many of their properties and the character of processes they are involved in. At the same time, determining the temperature of free clusters and nanoparticles in molecular beams is a rather complicated problem because the temperature of small particles depends on their size. In this paper, recently developed kinetic methods for measuring the temperature of clusters and nanoparticles in molecular beams are reviewed. The definition of temperature in the present context is given, and how the temperature affects the properties of and the processes involving the particles is discussed. The temperature behavior of clusters and nanoparticles near a phase transition point is analyzed. Early methods for measuring the temperature of large clusters are briefly described. It is shown that, compared to other methods, new kinetic methods are more universal and applicable for determining the temperature of clusters and nanoparticles of practically any size and composition. The future development and applications of these methods are outlined. (reviews of topical problems)

  7. Simulation of the Beam-Beam Effects in e+e- Storage Rings with a Method of Reducing the Region of Mesh

    Energy Technology Data Exchange (ETDEWEB)

    Cai, Yunhai

    2000-08-31

    A highly accurate self-consistent particle code to simulate the beam-beam collision in e{sup +}e{sup -} storage rings has been developed. It adopts a method of solving the Poisson equation with an open boundary. The method consists of two steps: assigning the potential on a finite boundary using the Green's function, and then solving the potential inside the boundary with a fast Poisson solver. Since the solution of the Poisson's equation is unique, the authors solution is exactly the same as the one obtained by simply using the Green's function. The method allows us to select much smaller region of mesh and therefore increase the resolution of the solver. The better resolution makes more accurate the calculation of the dynamics in the core of the beams. The luminosity simulated with this method agrees quantitatively with the measurement for the PEP-II B-factory ring in the linear and nonlinear beam current regimes, demonstrating its predictive capability in detail.

  8. An MLC-based version for the ecliptic method for the determination of backscatter into the beam monitor chambers in photon beams of medical accelerators

    International Nuclear Information System (INIS)

    Nelli, Flavio Enrico

    2016-01-01

    A very simple method to measure the effect of the backscatter from secondary collimators into the beam monitor chambers in linear accelerators equipped with multi-leaf collimators (MLC) is presented here. The backscatter to the monitor chambers from the upper jaws of the secondary collimator was measured on three beam-matched linacs by means of three methods: this new methodology, the ecliptic method, and assessing the variation of the beam-on time per monitor unit with dose rate feedback disabled. This new methodology was used to assess the backscatter characteristics of asymmetric over-traveling jaws. Excellent agreement between the backscatter values measured using the new methodology introduced here and the ones obtained using the other two methods was established. The experimental values reported here differ by less than 1 % from published data. The sensitivity of this novel technique allowed differences in backscatter due to the same opening of the jaws, when placed at different positions on the beam path, to be resolved. The introduction of the ecliptic method has made the determination of the backscatter to the monitor chambers an easy procedure. The method presented here for machines equipped with MLCs makes the determination of backscatter to the beam monitor chambers even easier, and suitable to characterize linacs equipped with over-traveling asymmetric secondary collimators. This experimental procedure could be simply implemented to fully characterize the backscatter output factor constituent when detailed dosimetric modeling of the machine’s head is required. The methodology proved to be uncomplicated, accurate and suitable for clinical or experimental environments.

  9. A Novel Adjustment Method for Shearer Traction Speed through Integration of T-S Cloud Inference Network and Improved PSO

    Directory of Open Access Journals (Sweden)

    Lei Si

    2014-01-01

    Full Text Available In order to efficiently and accurately adjust the shearer traction speed, a novel approach based on Takagi-Sugeno (T-S cloud inference network (CIN and improved particle swarm optimization (IPSO is proposed. The T-S CIN is built through the combination of cloud model and T-S fuzzy neural network. Moreover, the IPSO algorithm employs parameter automation adjustment strategy and velocity resetting to significantly improve the performance of basic PSO algorithm in global search and fine-tuning of the solutions, and the flowchart of proposed approach is designed. Furthermore, some simulation examples are carried out and comparison results indicate that the proposed method is feasible, efficient, and is outperforming others. Finally, an industrial application example of coal mining face is demonstrated to specify the effect of proposed system.

  10. A method to adjust for ascertainment bias in the evaluation of cancer registry data.

    Science.gov (United States)

    Fallah, Mahdi; Kharazmi, Elham

    2007-01-01

    Using the trend of age-standardized incidence rate of cancers (ASR) is inaccurate for registration with incomplete reporting, especially in developing registries. The relative age-standardized ratio (RASR) is a new measure that takes ascertainment bias of registration into account. RASR is calculated from the ASR for each cancer divided by the ASR for leukemia. Leukemia was chosen as the reference because its ASR is rather constant over time in valid registries. The adjusted relative age-standardized rate (ARASR with same unit as ASR) is calculated by multiplying the RASR for a specific cancer in a particular year by the sum of ASRs of that cancer over the years for which a trend is being determined and then dividing result by the sum of RASRs of the cancer for those years. Two likely assumptions are behind use of ARASR, first, constant ASR of leukemia over time, second, if under/over-registration occurs, it happens for all cancers to the same extent (random under/over-reporting). Using the ARASR with empirical data of valid Finnish and SEER cancer registries proved that trend of ASRs for each cancer is almost equal to its ARASR. Using trends of ARASRs instead of ASRs in a registry with incomplete data collection in first years of registration demonstrated more realistic results. In conclusion, the ARASR is more accurate than the ASR for studying cancer incidence trends in registries with incomplete reporting. ARASRs in different countries or different times are comparable since they are age-standardized. Moreover, comparison between trends of ASRs and ARASRs can be used as a test for validity of registration.

  11. Shaft adjuster

    Science.gov (United States)

    Harry, Herbert H.

    1989-01-01

    Apparatus and method for the adjustment and alignment of shafts in high power devices. A plurality of adjacent rotatable angled cylinders are positioned between a base and the shaft to be aligned which when rotated introduce an axial offset. The apparatus is electrically conductive and constructed of a structurally rigid material. The angled cylinders allow the shaft such as the center conductor in a pulse line machine to be offset in any desired alignment position within the range of the apparatus.

  12. Characterization for Ceramic-coated magnets using E-beam and thermal annealing methods

    International Nuclear Information System (INIS)

    Kim, Hyug Jong; Kim, Hee Gyu; Kang, In Gu; Kim, Min Wan; Yang, Ki Ho; Lee, Byung Cheol; Choi, Byung Ho

    2009-01-01

    Hard magnet was usually used by coating SiO 2 ceramic thick films followed by the thermal annealing process. In this work, the alternative annealing process for NdFeB magnets using e-beam sources(1∼2 MeV, 50∼400 kGy) was investigated. NdFeB magnets was coated with ceramic thick films using the spray method. The optimal annealing parameter for e-beam source reveals to be 1 MeV and 300 kGy. The sample prepared at 1 MeV and 300 kGy was characterized by the analysis of the surface morphology, film hardness, adhesion and chemical stability. The mechanical property of thick film, especially film hardness, is better than that of thermal annealed samples at 180 .deg. C. As a result, e-beam annealing process will be one of candidate and attractive heat treatment process. In future, manufacturing process will be carried out in cooperation with the magnet company

  13. An Efficient Estimation Method for Reducing the Axial Intensity Drop in Circular Cone-Beam CT

    Directory of Open Access Journals (Sweden)

    Lei Zhu

    2008-01-01

    Full Text Available Reconstruction algorithms for circular cone-beam (CB scans have been extensively studied in the literature. Since insufficient data are measured, an exact reconstruction is impossible for such a geometry. If the reconstruction algorithm assumes zeros for the missing data, such as the standard FDK algorithm, a major type of resulting CB artifacts is the intensity drop along the axial direction. Many algorithms have been proposed to improve image quality when faced with this problem of data missing; however, development of an effective and computationally efficient algorithm remains a major challenge. In this work, we propose a novel method for estimating the unmeasured data and reducing the intensity drop artifacts. Each CB projection is analyzed in the Radon space via Grangeat's first derivative. Assuming the CB projection is taken from a parallel beam geometry, we extract those data that reside in the unmeasured region of the Radon space. These data are then used as in a parallel beam geometry to calculate a correction term, which is added together with Hu’s correction term to the FDK result to form a final reconstruction. More approximations are then made on the calculation of the additional term, and the final formula is implemented very efficiently. The algorithm performance is evaluated using computer simulations on analytical phantoms. The reconstruction comparison with results using other existing algorithms shows that the proposed algorithm achieves a superior performance on the reduction of axial intensity drop artifacts with a high computation efficiency.

  14. An Algebraic Method of Synchronous Pulsewidth Modulation for Converters for Adjustable Speed Drives

    DEFF Research Database (Denmark)

    Oleschuk, Valentin; Blaabjerg, Frede

    2002-01-01

    This paper describes the basic peculiarities of a new method of feedforward synchronous pulsewidth modulation (PWM) of the output voltage of converters, based on one-stage closed-form strategy of PWM with pure algebraic control dependencies. It is applied to voltage source inverters with a contin......This paper describes the basic peculiarities of a new method of feedforward synchronous pulsewidth modulation (PWM) of the output voltage of converters, based on one-stage closed-form strategy of PWM with pure algebraic control dependencies. It is applied to voltage source inverters...... with a continuous scheme of conventional voltage space vector modulation and with two basic variants of symmetrical discontinuous PWM. Simulations give the behaviour of the proposed method and show the advantage of algebraic synchronous PWM compared with the typical asynchronous, for low indices of the frequency...

  15. Adjustment of a rapid method for quantification of Fusarium spp. spore suspensions in plant pathology.

    Science.gov (United States)

    Caligiore-Gei, Pablo F; Valdez, Jorge G

    2015-01-01

    The use of a Neubauer chamber is a broadly employed method when cell suspensions need to be quantified. However, this technique may take a long time and needs trained personnel. Spectrophotometry has proved to be a rapid, simple and accurate method to estimate the concentration of spore suspensions of isolates of the genus Fusarium. In this work we present a linear formula to relate absorbance measurements at 530nm with the number of microconidia/ml in a suspension. Copyright © 2014 Asociación Argentina de Microbiología. Publicado por Elsevier España, S.L.U. All rights reserved.

  16. A real-time automatic contrast adjustment method for high-bit-depth cameras based on histogram variance analysis

    Science.gov (United States)

    Zhao, Jun; Lu, Jun

    2015-10-01

    In this paper we propose an efficient method to enhance contrast in real time in digital video streams by exploiting histogram variances and adaptively adjusting gamma curves. The proposed method aims to overcome the limitations of the conventional histogram equalization method, which often produces noisy, unrealistic effects in images. To improve visual quality, we use gamma correction technique and choose different gamma curves according to the histogram variance of the images. By using this scheme, the details of an image can be enhanced while the mean brightness level is kept. Experiment results demonstrate that our method is simple and efficient, and robust for both low and high dynamic scenes, and hence well suited for real-time, high-bit-depth video acquisitions.

  17. Analytical Investigation of Beam Deformation Equation using Perturbation, Homotopy Perturbation, Variational Iteration and Optimal Homotopy Asymptotic Methods

    DEFF Research Database (Denmark)

    Farrokhzad, F.; Mowlaee, P.; Barari, Amin

    2011-01-01

    The beam deformation equation has very wide applications in structural engineering. As a differential equation, it has its own problem concerning existence, uniqueness and methods of solutions. Often, original forms of governing differential equations used in engineering problems are simplified, ...

  18. Beam cooling

    OpenAIRE

    Danared, H

    2006-01-01

    Beam cooling is the technique of reducing the momentum spread and increasing the phase-space density of stored particle beams. This paper gives an introduction to beam cooling and Liouville’s theorem, and then it describes the three methods of active beam cooling that have been proven to work so far, namely electron cooling, stochastic cooling, and laser cooling. Ionization cooling is also mentioned briefly.

  19. A Self-Adjusting Method to Resist Bus Bunching Based on Boarding Limits

    OpenAIRE

    Zhao, Shuzhi; Lu, Chunxiu; Liang, Shidong; Liu, Huasheng

    2016-01-01

    Bus bunching is one of the most serious problems of urban bus systems. Bus bunching increases waiting and travel time of passengers. Many bus systems use schedules to reach equal headways. Compared to the idea of schedules and the target headway introduced later, we propose a new method to improve the efficiency of a bus system and avoid bus bunching by boarding limits. Our solution can be effectively implemented when buses cannot travel as planned because of bad road conditions and dynamic d...

  20. Reaction mechanism of oxygen atoms with unsaturated hydrocarbons by the crossed molecular beams method

    Energy Technology Data Exchange (ETDEWEB)

    Buss, R.J.; Baseman, R.J.; Guozhong, H.; Lee, Y.T.

    1982-04-01

    From a series of studies of the reaction of oxygen atoms with unsaturated hydrocarbons using the crossed molecular beam method, the dominant reaction mechanisms were found to be the simple substitution reactions with oxygen atoms replacing H, Cl, Br atom or alkyl groups. Complication due to secondary reaction was avoided by carrying out experiments under single collisions and observing primary products directly. Primary products were identified by measuring the angular and velocity distributions of products at all the mass numbers which could be detected by the mass spectrometer, and from comparison of these distributions, applying the requirement of energy and momentum conservation.

  1. A comparison of residual stresses in built-up steel beams using hole-drilling method

    International Nuclear Information System (INIS)

    Nawafleh, M. A.; Hunaiti, Y. M.; Younes, R. M.

    2009-01-01

    Residual stresses have a significant effect on the stability resistance of metal building systems. An experimental program was conducted to measure these stresses in built-up steel beams using incremental hole-drilling method. The experimental results reveal that the predicted residual stress type of pattern for built-up I-sections with fillet welds on one side of the web is not the same as the pattern of residual stresses in built-up I-sections with fillet welds on both sides of the web

  2. A novel process control method for a TT-300 E-Beam/X-Ray system

    Science.gov (United States)

    Mittendorfer, Josef; Gallnböck-Wagner, Bernhard

    2018-02-01

    This paper presents some aspects of the process control method for a TT-300 E-Beam/X-Ray system at Mediscan, Austria. The novelty of the approach is the seamless integration of routine monitoring dosimetry with process data. This allows to calculate a parametric dose for each production unit and consequently a fine grain and holistic process performance monitoring. Process performance is documented in process control charts for the analysis of individual runs as well as historic trending of runs of specific process categories over a specified time range.

  3. Resistive wall impedance of the LHC beam screen without slots calculated by boundary element method

    CERN Document Server

    Tsutsui, H

    2002-01-01

    In order to calculate the resistive wall impedance of the LHC beam screen without slots, the Boundary Element Method (BEM) is used. The result at 1 GHz is Re(ZL/L) = 6.689×10−3 Ω/m, Re(Zx/L) = 1.251 Ω/m2, Re(Zy/L) = 1.776 Ω/m2, andRe(2Z0,2 cos/kL) = −0.525 Ω/m2, assuming σ = 5.8 × 109 /Ωm.

  4. Reaction Mechanism of Oxygen Atoms with Unsaturated Hydrocarbons by the Crossed-Molecular-Beams Method

    Science.gov (United States)

    Buss, R. J.; Baseman, R. J.; Guozhong, H.; Lee, Y. T.

    1982-04-01

    From a series of studies of the reaction of oxygen atoms with unsaturated hydrocarbons using the crossed molecular beam method, the dominant reaction mechanisms were found to be the simple substitution reactions with oxygen atoms replacing H, Cl, Br atom or alkyl groups. Complication due to secondary reaction was avoided by carrying out experiments under single collisions and observing primary products directly. Primary products were identified by measuring the angular and velocity distributions of products at all the mass numbers which could be detected by the mass spectrometer, and from comparison of these distributions, applying the requirement of energy and momentum conservation.

  5. A thermography-based method for fatigue behavior evaluation of coupling beam damper

    Directory of Open Access Journals (Sweden)

    Zhe Zhang

    2017-04-01

    Full Text Available Under cyclic load, local fatigue damage will occur in the metal damper widely used in the shear wall. This will deteriorate the stiffness of damper and weaken the hysteresis behaviour. The present paper proposed a new and easy method to manufacture kinds of coupling beam dampers. A thermography-based experiment was used to study the energy dissipation and damage accumulation during fatigue process of the metal damper. Based on the temperature variation related to fatigue damage process, the relationship between the plastic deformation and thermal energy dissipation was quantitatively established. Besides, the relationships between the temperature increase to damage accumulation and mechanical load were analyzed systematically.

  6. Diffracted beam-transmitted beam Borrmann X-ray topography in copper. A novel method of stereo depth topography

    International Nuclear Information System (INIS)

    Hamill, G.P.; Vreeland, T. Jr.

    1979-01-01

    The observed depths of dislocations, as measured from the exit surface of a copper single crystal, are within a region of the crystal where μd, the kinematic linear absorption coefficient times the depth, is less than or approximately equal to unity. Splitting of the Borrmann wave into its diffracted and transmitted beam components is indicated in relatively perfect portions of the crystal near the exit surface. (Auth.)

  7. A novel method to adjust efficacy estimates for uptake of other active treatments in long-term clinical trials.

    Directory of Open Access Journals (Sweden)

    John Simes

    2010-01-01

    Full Text Available When rates of uptake of other drugs differ between treatment arms in long-term trials, the true benefit or harm of the treatment may be underestimated. Methods to allow for such contamination have often been limited by failing to preserve the randomization comparisons. In the Fenofibrate Intervention and Event Lowering in Diabetes (FIELD study, patients were randomized to fenofibrate or placebo, but during the trial many started additional drugs, particularly statins, more so in the placebo group. The effects of fenofibrate estimated by intention-to-treat were likely to have been attenuated. We aimed to quantify this effect and to develop a method for use in other long-term trials.We applied efficacies of statins and other cardiovascular drugs from meta-analyses of randomized trials to adjust the effect of fenofibrate in a penalized Cox model. We assumed that future cardiovascular disease events were reduced by an average of 24% by statins, and 20% by a first other major cardiovascular drug. We applied these estimates to each patient who took these drugs for the period they were on them. We also adjusted the analysis by the rate of discontinuing fenofibrate. Among 4,900 placebo patients, average statin use was 16% over five years. Among 4,895 assigned fenofibrate, statin use was 8% and nonuse of fenofibrate was 10%. In placebo patients, use of cardiovascular drugs was 1% to 3% higher. Before adjustment, fenofibrate was associated with an 11% reduction in coronary events (coronary heart disease death or myocardial infarction (P = 0.16 and an 11% reduction in cardiovascular disease events (P = 0.04. After adjustment, the effects of fenofibrate on coronary events and cardiovascular disease events were 16% (P = 0.06 and 15% (P = 0.008, respectively.This novel application of a penalized Cox model for adjustment of a trial estimate of treatment efficacy incorporates evidence-based estimates for other therapies, preserves comparisons between the

  8. MANGO – Modal Analysis for Grid Operation: A Method for Damping Improvement through Operating Point Adjustment

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Zhenyu; Zhou, Ning; Tuffner, Francis K.; Chen, Yousu; Trudnowski, Daniel J.; Diao, Ruisheng; Fuller, Jason C.; Mittelstadt, William A.; Hauer, John F.; Dagle, Jeffery E.

    2010-10-18

    Small signal stability problems are one of the major threats to grid stability and reliability in the U.S. power grid. An undamped mode can cause large-amplitude oscillations and may result in system breakups and large-scale blackouts. There have been several incidents of system-wide oscillations. Of those incidents, the most notable is the August 10, 1996 western system breakup, a result of undamped system-wide oscillations. Significant efforts have been devoted to monitoring system oscillatory behaviors from measurements in the past 20 years. The deployment of phasor measurement units (PMU) provides high-precision, time-synchronized data needed for detecting oscillation modes. Measurement-based modal analysis, also known as ModeMeter, uses real-time phasor measurements to identify system oscillation modes and their damping. Low damping indicates potential system stability issues. Modal analysis has been demonstrated with phasor measurements to have the capability of estimating system modes from both oscillation signals and ambient data. With more and more phasor measurements available and ModeMeter techniques maturing, there is yet a need for methods to bring modal analysis from monitoring to actions. The methods should be able to associate low damping with grid operating conditions, so operators or automated operation schemes can respond when low damping is observed. The work presented in this report aims to develop such a method and establish a Modal Analysis for Grid Operation (MANGO) procedure to aid grid operation decision making to increase inter-area modal damping. The procedure can provide operation suggestions (such as increasing generation or decreasing load) for mitigating inter-area oscillations.

  9. A Dynamic Localized Adjustable Force Field Method for Real-Time Assistive Non-Holonomic Mobile Robotics

    Directory of Open Access Journals (Sweden)

    Michael Gillham

    2015-10-01

    Full Text Available Providing an assistive navigation system that augments rather than usurps user control of a powered wheelchair represents a significant technical challenge. This paper evaluates an assistive collision avoidance method for a powered wheelchair that allows the user to navigate safely whilst maintaining their overall governance of the platform motion. The paper shows that by shaping, switching and adjusting localized potential fields we are able to negotiate different obstacles by generating a more intuitively natural trajectory, one that does not deviate significantly from the operator in the loop desired-trajectory. It can also be seen that this method does not suffer from the local minima problem, or narrow corridor and proximity oscillation, which are common problems that occur when using potential fields. Furthermore this localized method enables the robotic platform to pass very close to obstacles, such as when negotiating a narrow passage or doorway.

  10. Method to evaluate the L/D ratio of neutron imaging beams

    Energy Technology Data Exchange (ETDEWEB)

    Pugliesi, R.; Pereira, M.A. Stanojev; Schoueri, R.M., E-mail: pugliesi@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2017-04-01

    An alternative simple method to evaluate the L/D ratio of neutron imaging beams is proposed. It is based on the behavior of the ratio 'x/Ut', which asymptotically tends to L/D for large values of the parameter 'x', that corresponds to the distance separating a gadolinium test object to the scintillator plane, where its image is formed. The method was applied to the neutron imaging equipment of the Nuclear and Energy Research Institute IPEN/CNEN-SP and the obtained result was L/D = (104 ± 4). The consistency of the proposed method was verified by comparing this value with those ones obtained by a well - known and established procedure. (author)

  11. Dual axis translation apparatus and system for translating an optical beam and related method

    Science.gov (United States)

    Cassidy, Kelly

    1991-01-01

    A dual axis translation device and system in accordance with this invention, for translating an optical beam along both an x-axis and a y-axis which are perpendicular to one another, has a beam directing means acting on said optical beam for directing the beam along a particular path transverse to said x and y axes. An arrangement supporting said beam directing means for movement in the x and y direction within a given plane is provided. The arrangement includes a first means for translating said beam directing means along the x-axis in said given plane in order to translate the beam along said x-axis. The arrangement comprises a second means for translating said beam directing means along the y-axis in said given plane in order to translate the beam along said y-axis.

  12. Towards a Generic Method for Building-Parcel Vector Data Adjustment by Least Squares

    Science.gov (United States)

    Méneroux, Y.; Brasebin, M.

    2015-08-01

    Being able to merge high quality and complete building models with parcel data is of a paramount importance for any application dealing with urban planning. However since parcel boundaries often stand for the legal reference frame, the whole correction will be exclusively done on building features. Then a major task is to identify spatial relationships and properties that buildings should keep through the conflation process. The purpose of this paper is to describe a method based on least squares approach to ensure that buildings fit consistently into parcels while abiding by a set of standard constraints that may concern most of urban applications. An important asset of our model is that it can be easily extended to comply with more specific constraints. In addition, results analysis also demonstrates that it provides significantly better output than a basic algorithm relying on an individual correction of features, especially regarding conservation of metrics and topological relationships between buildings. In the future, we would like to include more specific constraints to retrieve the actual positions of buildings relatively to parcel borders and we plan to assess the contribution of our algorithm on the quality of urban application outputs.

  13. Method and apparatus for rapid adjustment of process gas inventory in gaseous diffusion cascades

    International Nuclear Information System (INIS)

    1980-01-01

    A method is specified for the operation of a gaseous diffusion cascade wherein electrically driven compressors circulate a process gas through a plurality of serially connected gaseous diffusion stages to establish first and second countercurrently flowing cascade streams of process gas, one of the streams being at a relatively low pressure and enriched in a component of the process gas and the other being at a higher pressure and depleted in the same, and wherein automatic control systems maintain the stage process gas pressures by positioning process gas flow control valve openings at values which are functions of the difference between reference-signal inputs to the systems, and signal inputs proportional to the process gas pressures in the gaseous diffusion stages associated with the systems, the cascade process gas inventory being altered, while the cascade is operating, by simultaneously directing into separate process-gas freezing zones a plurality of substreams derived from one of the first and second streams at different points along the lengths thereof to solidify approximately equal weights of process gas in the zone while reducing the reference-signal inputs to maintain the positions of the control valves substantially unchanged despite the removal of process gas inventory via the substreams. (author)

  14. Normalized impact factor (NIF): an adjusted method for calculating the citation rate of biomedical journals.

    Science.gov (United States)

    Owlia, P; Vasei, M; Goliaei, B; Nassiri, I

    2011-04-01

    The interests in journal impact factor (JIF) in scientific communities have grown over the last decades. The JIFs are used to evaluate journals quality and the papers published therein. JIF is a discipline specific measure and the comparison between the JIF dedicated to different disciplines is inadequate, unless a normalization process is performed. In this study, normalized impact factor (NIF) was introduced as a relatively simple method enabling the JIFs to be used when evaluating the quality of journals and research works in different disciplines. The NIF index was established based on the multiplication of JIF by a constant factor. The constants were calculated for all 54 disciplines of biomedical field during 2005, 2006, 2007, 2008 and 2009 years. Also, ranking of 393 journals in different biomedical disciplines according to the NIF and JIF were compared to illustrate how the NIF index can be used for the evaluation of publications in different disciplines. The findings prove that the use of the NIF enhances the equality in assessing the quality of research works produced by researchers who work in different disciplines. Copyright © 2010 Elsevier Inc. All rights reserved.

  15. [Structural adjustment, cultural adjustment?].

    Science.gov (United States)

    Dujardin, B; Dujardin, M; Hermans, I

    2003-12-01

    Over the last two decades, multiple studies have been conducted and many articles published about Structural Adjustment Programmes (SAPs). These studies mainly describe the characteristics of SAPs and analyse their economic consequences as well as their effects upon a variety of sectors: health, education, agriculture and environment. However, very few focus on the sociological and cultural effects of SAPs. Following a summary of SAP's content and characteristics, the paper briefly discusses the historical course of SAPs and the different critiques which have been made. The cultural consequences of SAPs are introduced and are described on four different levels: political, community, familial, and individual. These levels are analysed through examples from the literature and individual testimonies from people in the Southern Hemisphere. The paper concludes that SAPs, alongside economic globalisation processes, are responsible for an acute breakdown of social and cultural structures in societies in the South. It should be a priority, not only to better understand the situation and its determining factors, but also to intervene and act with strategies that support and reinvest in the social and cultural sectors, which is vital in order to allow for individuals and communities in the South to strengthen their autonomy and identify.

  16. Eigensensitivity analysis of rotating clamped uniform beams with the asymptotic numerical method

    Science.gov (United States)

    Bekhoucha, F.; Rechak, S.; Cadou, J. M.

    2016-12-01

    In this paper, free vibrations of a rotating clamped Euler-Bernoulli beams with uniform cross section are studied using continuation method, namely asymptotic numerical method. The governing equations of motion are derived using Lagrange's method. The kinetic and strain energy expression are derived from Rayleigh-Ritz method using a set of hybrid variables and based on a linear deflection assumption. The derived equations are transformed in two eigenvalue problems, where the first is a linear gyroscopic eigenvalue problem and presents the coupled lagging and stretch motions through gyroscopic terms. While the second is standard eigenvalue problem and corresponds to the flapping motion. Those two eigenvalue problems are transformed into two functionals treated by continuation method, the Asymptotic Numerical Method. New method proposed for the solution of the linear gyroscopic system based on an augmented system, which transforms the original problem to a standard form with real symmetric matrices. By using some techniques to resolve these singular problems by the continuation method, evolution curves of the natural frequencies against dimensionless angular velocity are determined. At high angular velocity, some singular points, due to the linear elastic assumption, are computed. Numerical tests of convergence are conducted and the obtained results are compared to the exact values. Results obtained by continuation are compared to those computed with discrete eigenvalue problem.

  17. The nuclear interaction analysis methods for diagnostics of high power ion beam technologies

    International Nuclear Information System (INIS)

    Ryzhkov, V.A.; Grushin, I.I.; Remnev, G.E.

    1996-01-01

    The complex of Nuclear Interaction Analysis Methods including charged particle activation analysis (CPAA and HIAA), spectrometry of ion induced gamma-emission (PIGE and HIIGE) , characteristic X-ray emission (PIXE), and Rutherford Backscattering Spectrometry (RBS), have been used for diagnostics of the High Power Ion Beam (HPIB) assisted technologies. Accelerated ion beams from the EG-2.5 electrostatic generator and U-120 cyclotron were used for implementation of the techniques. The complex allows a lot of problems of elemental and isotopic analysis to be addressed. First, it is the determination of micro- and macrocomponents of modified materials; second, determination of surface density of thin films, multilayers and coatings, total surface gaseous contamination and amounts of the elements implanted in specimens; third, measurement of concentration depth profiles of the elements. Experiments have shown that the preferable application of nuclear analysis methods allows us to avoid the considerable errors arising when the concentration depth profiles of elements are measured by SIMS or AES in studies of mass transfer processes induced by HPIBs. (author). 1 tab., 2 figs., 3 refs

  18. SU-F-T-242: A Method for Collision Avoidance in External Beam Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Buzurovic, I; Cormack, R [Dana-Farber/Brigham and Women’s Cancer Center, Harvard Medical School, Boston, MA (United States)

    2016-06-15

    Purpose: We proposed a method for collision avoidance (CA) in external beam radiation therapy (EBRT). The method encompasses the analysis of all positions of the moving components of the beam delivery system such as the treatment table and gantry, including patient specific information obtained from the CT images. This method eliminates the need for time-consuming dry-runs prior to the actual treatments. Methods: The QA procedure for EBRT requires that the collision should be checked prior to treatment. We developed a system capable of a rigorous computer simulation of all moving components including positions of the couch and gantry during the delivery, position of the patients, and imaging equipment. By running this treatment simulation it is possible to quantify and graphically represent all positions and corresponding trajectories of all points of the moving parts during the treatment delivery. The development of the workflow for implementation of the CA includes several steps: a) derivation of combined dynamic equation of motion of the EBRT delivery systems, b) developing the simulation model capable of drawing the motion trajectories of the specific points, c) developing the interface between the model and the treatment plan parameters such as couch and gantry parameters for each field. Results: The patient CT images were registered to the treatment couch so the patient dimensions were included into the simulation. The treatment field parameters were structured in the xml-file which was used as the input into the dynamic equations. The trajectories of the moving components were plotted on the same graph using the dynamic equations. If the trajectories intersect that was the signal that collision exists. Conclusion: This CA method was proved to be effective in the simulation of treatment delivery. The proper implementation of this system can potentially improve the QA program and increase the efficacy in the clinical setup.

  19. Qualitative Analysis of Chang'e-1 γ-ray Spectrometer Spectra Using Noise Adjusted Singular Value Decomposition Method

    International Nuclear Information System (INIS)

    Yang Jia; Ge Liangquan; Xiong Shengqing

    2010-01-01

    From the features of spectra shape of Chang'e-1 γ-ray spectrometer(CE1-GRS) data, it is difficult to determine elemental compositions on the lunar surface. Aimed at this problem, this paper proposes using noise adjusted singular value decomposition (NASVD) method to extract orthogonal spectral components from CE1-GRS data. Then the peak signals in the spectra of lower-order layers corresponding to the observed spectrum of each lunar region are respectively analyzed. Elemental compositions of each lunar region can be determined based upon whether the energy corresponding to each peak signal equals to the energy corresponding to the characteristic gamma-ray line emissions of specific elements. The result shows that a number of elements such as U, Th, K, Fe, Ti, Si, O, Al, Mg, Ca and Na are qualitatively determined by this method. (authors)

  20. An efficient and accurate method for computation of energy release rates in beam structures with longitudinal cracks

    DEFF Research Database (Denmark)

    Blasques, José Pedro Albergaria Amaral; Bitsche, Robert

    2015-01-01

    This paper proposes a novel, efficient, and accurate framework for fracture analysis of beam structures with longitudinal cracks. The three-dimensional local stress field is determined using a high-fidelity beam model incorporating a finite element based cross section analysis tool. The Virtual...... Crack Closure Technique is used for computation of strain energy release rates. The devised framework was employed for analysis of cracks in beams with different cross section geometries. The results show that the accuracy of the proposed method is comparable to that of conventional three...

  1. Bartlett-type corrections and bootstrap adjustments of likelihood-based inference methods for network meta-analysis.

    Science.gov (United States)

    Noma, Hisashi; Nagashima, Kengo; Maruo, Kazushi; Gosho, Masahiko; Furukawa, Toshi A

    2018-03-30

    In network meta-analyses that synthesize direct and indirect comparison evidence concerning multiple treatments, multivariate random effects models have been routinely used for addressing between-studies heterogeneities. Although their standard inference methods depend on large sample approximations (eg, restricted maximum likelihood estimation) for the number of trials synthesized, the numbers of trials are often moderate or small. In these situations, standard estimators cannot be expected to behave in accordance with asymptotic theory; in particular, confidence intervals cannot be assumed to exhibit their nominal coverage probabilities (also, the type I error probabilities of the corresponding tests cannot be retained). The invalidity issue may seriously influence the overall conclusions of network meta-analyses. In this article, we develop several improved inference methods for network meta-analyses to resolve these problems. We first introduce 2 efficient likelihood-based inference methods, the likelihood ratio test-based and efficient score test-based methods, in a general framework of network meta-analysis. Then, to improve the small-sample inferences, we developed improved higher-order asymptotic methods using Bartlett-type corrections and bootstrap adjustment methods. The proposed methods adopt Monte Carlo approaches using parametric bootstraps to effectively circumvent complicated analytical calculations of case-by-case analyses and to permit flexible application to various statistical models network meta-analyses. These methods can also be straightforwardly applied to multivariate meta-regression analyses and to tests for the evaluation of inconsistency. In numerical evaluations via simulations, the proposed methods generally performed well compared with the ordinary restricted maximum likelihood-based inference method. Applications to 2 network meta-analysis datasets are provided. Copyright © 2017 John Wiley & Sons, Ltd.

  2. Interactive Analysis of General Beam Configurations using Finite Element Methods and JavaScript

    Science.gov (United States)

    Hernandez, Christopher

    Advancements in computer technology have contributed to the widespread practice of modelling and solving engineering problems through the use of specialized software. The wide use of engineering software comes with the disadvantage to the user of costs from the required purchase of software licenses. The creation of accurate, trusted, and freely available applications capable of conducting meaningful analysis of engineering problems is a way to mitigate to the costs associated with every-day engineering computations. Writing applications in the JavaScript programming language allows the applications to run within any computer browser, without the need to install specialized software, since all internet browsers are equipped with virtual machines (VM) that allow the browsers to execute JavaScript code. The objective of this work is the development of an application that performs the analysis of a completely general beam through use of the finite element method. The app is written in JavaScript and embedded in a web page so it can be downloaded and executed by a user with an internet connection. This application allows the user to analyze any uniform or non-uniform beam, with any combination of applied forces, moments, distributed loads, and boundary conditions. Outputs for this application include lists the beam deformations and slopes, as well as lateral and slope deformation graphs, bending stress distributions, and shear and a moment diagrams. To validate the methodology of the GBeam finite element app, its results are verified using the results from obtained from two other established finite element solvers for fifteen separate test cases.

  3. An optimized calibration method for surface measurements with MOSFETs in shaped-beam radiosurgery.

    Science.gov (United States)

    Sors, A; Cassol, E; Latorzeff, I; Duthil, P; Sabatier, J; Lotterie, J A; Redon, A; Berry, I; Franceries, X

    2014-02-01

    Nowadays MOSFET dosimeters are widely used for dose verification in radiotherapy procedures. Although their sensitive area satisfies size requirements for small field dosimetry, their use in radiosurgery has rarely been reported. The aim of this study is to propose and optimize a calibration method to perform surface measurements in 6 MV shaped-beam radiosurgery for field sizes down to 18 × 18 mm(2). The effect of different parameters such as recovery time between 2 readings, batch uniformity and build-up cap attenuation was studied. Batch uniformity was found to be within 2% and isocenter dose attenuation due to the build-up cap over the MOSFET was near 2% irrespective of field size. Two sets of sensitivity coefficients (SC) were determined for TN-502RD MOSFET dosimeters using experimental and calculated calibration; the latter being developed using an inverse square law model. Validation measurements were performed on a realistic head phantom in irregular fields. MOSFET dose values obtained by applying either measured or calculated SC were compared. For calibration, optimal results were obtained for an inter-measurement time lapse of 5 min. We also found that fitting the SC values with the inverse square law reduced the number of measurements required for calibration. The study demonstrated that combining inverse square law and Sterling-Worthley formula resulted in an underestimation of up to 4% of the dose measured by MOSFETs for complex beam geometries. With the inverse square law, it is possible to reduce the number of measurements required for calibration for multiple field-SSD combinations. Our results suggested that MOSFETs are suitable sensors for dosimetry when used at the surface in shaped-beam radiosurgery down to 18 × 18 mm(2). Copyright © 2013 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  4. A visualization method for probing grain boundaries of single layer graphene via molecular beam epitaxy

    Science.gov (United States)

    Zhan, Linjie; Wan, Wen; Zhu, Zhenwei; Zhao, Zhijuan; Zhang, Zhenhan; Shih, Tien-Mo; Cai, Weiwei

    2017-07-01

    Graphene, a member of layered two-dimensional (2D) materials, possesses high carrier mobility, mechanical flexibility, and optical transparency, as well as enjoying a wide range of promising applications in electronics. Adopting the chemical vaporization deposition method, the majority of investigators have ubiquitously grown single layer graphene (SLG), which inevitably involves polycrystalline properties. Here we demonstrate a simple method for the direct visualization of arbitrarily large-size SLG domains by synthesizing one-hundred-nm-scale MoS2 single crystals via a high-vacuum molecular beam epitaxy process. The present study based on epitaxial growth provides a guide for probing the grain boundaries of various 2D materials and implements higher potentials for the next-generation electronic devices.

  5. Beam Based Measurements of Field Multipoles in the RHIC Low Beta Insertions and Extrapolation of the Method to the LHC

    CERN Document Server

    Koutchouk, Jean-Pierre; Ptitsyn, V I

    2001-01-01

    The multipolar content of the dipoles and quadrupoles is known to limit the stability of the beam dynamics in super-conducting machines like RHIC and even more in LHC. The low-beta quadrupoles are thus equipped with correcting coils up to the dodecapole order. The correction is planned to rely on magnetic measurements. We show that a relatively simple method allows an accurate measurement of the multipolar field aberrations using the beam. The principle is to displace the beam in the non-linear fields by local closed orbit bumps and to measure the variation of sensitive beam observable. The resolution and robustness of the method are found appropriate. Experimentation at RHIC showed clearly the presence of normal and skew sextupolar field components in addition to a skew quadrupolar component in the interaction regions. Higher-order components up to decapole order appear as well.

  6. Structural single and multiple crack detection in cantilever beams using a hybrid Cuckoo-Nelder-Mead optimization method

    Science.gov (United States)

    Moezi, Seyed Alireza; Zakeri, Ehsan; Zare, Amin

    2018-01-01

    In this study, the number, location and depth of cracks created in several Euler-Bernoulli beams, such as a simple beam and a more complex multi-step beam are investigated. The location and depth of the created cracks are determined using the hybrid Cuckoo-Nelder-Mead Optimization Algorithm (COA-NM) with high accuracy. The natural frequencies of the cracked beams are determined by solving frequency response equations, and performing modal test experiments. Results of COA-NM show a higher accuracy and convergence speed compared with other methods such as GA-NM, PSO-NM, GA, PSO, COA and several previous studies. Amount of calculations performed by COA-NM to achieve this accuracy is much less compared to other methods.

  7. Cone Beam X-Ray Luminescence Tomography Imaging Based on KA-FEM Method for Small Animals.

    Science.gov (United States)

    Chen, Dongmei; Meng, Fanzhen; Zhao, Fengjun; Xu, Cao

    2016-01-01

    Cone beam X-ray luminescence tomography can realize fast X-ray luminescence tomography imaging with relatively low scanning time compared with narrow beam X-ray luminescence tomography. However, cone beam X-ray luminescence tomography suffers from an ill-posed reconstruction problem. First, the feasibility of experiments with different penetration and multispectra in small animal has been tested using nanophosphor material. Then, the hybrid reconstruction algorithm with KA-FEM method has been applied in cone beam X-ray luminescence tomography for small animals to overcome the ill-posed reconstruction problem, whose advantage and property have been demonstrated in fluorescence tomography imaging. The in vivo mouse experiment proved the feasibility of the proposed method.

  8. Accuracy and reliability of a novel method for fusion of digital dental casts and cone beam computed tomography scans

    NARCIS (Netherlands)

    Rangel, F.A.; Maal, T.J.J.; Bronkhorst, E.M.; Breuning, K.H.; Schols, J.G.J.H.; Berge, S.J.; Kuijpers-Jagtman, A.M.

    2013-01-01

    Several methods have been proposed to integrate digital models into Cone Beam Computed Tomography scans. Since all these methods have some drawbacks such as radiation exposure, soft tissue deformation and time-consuming digital handling processes, we propose a new method to integrate digital dental

  9. Advanced methods for the computation of particle beam transport and the computation of electromagnetic fields and beam-cavity interactions. Progress report, July 1993--August 1994

    International Nuclear Information System (INIS)

    Dragt, A.J.; Gluckstern, R.L.

    1994-08-01

    The University of Maryland Dynamical Systems and Accelerator Theory Group has been carrying out long-term research work in the general area of Dynamical Systems with a particular emphasis on applications to Accelerator Physics. This work is broadly divided into two tasks: the computation of charged particle beam transport and the computation of electromagnetic fields and beam-cavity interactions. Each of these tasks is described briefly. Work is devoted both to the development of new methods and the application of these methods to problems of current interest in accelerator physics including the theoretical performance of present and proposed high energy machines. In addition to its research effort, the Dynamical Systems and Accelerator Theory Group is actively engaged in the education of students and postdoctoral research associates. Substantial progress in research has been made during the past year. These achievements are summarized in the following report

  10. Direct fourier methods in 3D-reconstruction from cone-beam data

    International Nuclear Information System (INIS)

    Axelsson, C.

    1994-01-01

    The problem of 3D-reconstruction is encountered in both medical and industrial applications of X-ray tomography. A method able to utilize a complete set of projections complying with Tuys condition was proposed by Grangeat. His method is mathematically exact and consists of two distinct phases. In phase 1 cone-beam projection data are used to produce the derivative of the radon transform. In phase 2, after interpolation, the radon transform data are used to reconstruct the three-dimensional object function. To a large extent our method is an extension of the Grangeat method. Our aim is to reduce the computational complexity, i.e. to produce a faster method. The most taxing procedure during phase 1 is computation of line-integrals in the detector plane. By applying the direct Fourier method in reverse for this computation, we reduce the complexity of phase 1 from O(N 4 ) to O(N 3 logN). Phase 2 can be performed either as a straight 3D-reconstruction or as a sequence of two 2D-reconstructions in vertical and horizontal planes, respectively. Direct Fourier methods can be applied for the 2D- and for the 3D-reconstruction, which reduces the complexity of phase 2 from O(N 4 ) to O(N 3 logN) as well. In both cases, linogram techniques are applied. For 3D-reconstruction the inversion formula contains the second derivative filter instead of the well-known ramp-filter employed in the 2D-case. The derivative filter is more well-behaved than the 2D ramp-filter. This implies that less zeropadding is necessary which brings about a further reduction of the computational efforts. The method has been verified by experiments on simulated data. The image quality is satisfactory and independent of cone-beam angles. For a 512 3 volume we estimate that our method is ten times faster than Grangeats method

  11. A manual beaming device: an improved method for warp winding in ...

    African Journals Online (AJOL)

    Challenges with broadloom beaming that affect the weaving process and eventually the woven fabric aspect, could be as a result of the great bulk of yarns attached to the weighted box for tensioning. This project sought to construct a beaming device that maintains even tension of warp yarn at beaming by reducing the ...

  12. Fabrication of oriented crystals as force measurement tips via focused ion beam and microlithography methods

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Zhigang [School of Science, North University of China, Shanxi 030051 China; Chun, Jaehun [Physical and Computational Sciences Directorate, Pacific Northwest National Laboratory, WA USA; Chatterjee, Sayandev [Energy and Environment Directorate, Pacific Northwest National Laboratory, WA USA; Li, Dongsheng [Physical and Computational Sciences Directorate, Pacific Northwest National Laboratory, WA USA

    2017-11-09

    Detailed knowledge of the forces between nanocrystals is very crucial for understanding many generic (e.g., random aggregation/assembly and rheology) and specific (e.g., oriented attachment) phenomena at macroscopic length scales, especially considering the additional complexities involved in nanocrystals such as crystal orientation and corresponding orientation-dependent physicochemical properties. Because there are a limited number of methods to directly measure the forces, little is known about the forces that drive the various emergent phenomena. Here we report on two methods of preparing crystals as force measurement tips used in an atomic force microscope (AFM): the focused ion beam method and microlithography method. The desired crystals are fabricated using these two methods and are fixed to the AFM probe using platinum deposition, ultraviolet epoxy, or resin, which allows for the orientation-dependent force measurements. These two methods can be used to attach virtually any solid particles (from the size of a few hundreds of nanometers to millimeters). We demonstrate the force measurements between aqueous media under different conditions such as pH.

  13. Laser and Electron Beam Additive Manufacturing Methods of Fabricating Titanium Bone Implants

    Directory of Open Access Journals (Sweden)

    Bartłomiej Wysocki

    2017-06-01

    Full Text Available Additive Manufacturing (AM methods are generally used to produce an early sample or near net-shape elements based on three-dimensional geometrical modules. To date, publications on AM of metal implants have mainly focused on knee and hip replacements or bone scaffolds for tissue engineering. The direct fabrication of metallic implants can be achieved by methods, such as Selective Laser Melting (SLM or Electron Beam Melting (EBM. This work compares the SLM and EBM methods used in the fabrication of titanium bone implants by analyzing the microstructure, mechanical properties and cytotoxicity. The SLM process was conducted in an environmental chamber using 0.4–0.6 vol % of oxygen to enhance the mechanical properties of a Ti-6Al-4V alloy. SLM processed material had high anisotropy of mechanical properties and superior UTS (1246–1421 MPa when compared to the EBM (972–976 MPa and the wrought material (933–942 MPa. The microstructure and phase composition depended on the used fabrication method. The AM methods caused the formation of long epitaxial grains of the prior β phase. The equilibrium phases (α + β and non-equilibrium α’ martensite was obtained after EBM and SLM, respectively. Although it was found that the heat transfer that occurs during the layer by layer generation of the component caused aluminum content deviations, neither methods generated any cytotoxic effects. Furthermore, in contrast to SLM, the EBM fabricated material met the ASTMF136 standard for surgical implant applications.

  14. Free vibration of functionally graded beams and frameworks using the dynamic stiffness method

    Science.gov (United States)

    Banerjee, J. R.; Ananthapuvirajah, A.

    2018-05-01

    The free vibration analysis of functionally graded beams (FGBs) and frameworks containing FGBs is carried out by applying the dynamic stiffness method and deriving the elements of the dynamic stiffness matrix in explicit algebraic form. The usually adopted rule that the material properties of the FGB vary continuously through the thickness according to a power law forms the fundamental basis of the governing differential equations of motion in free vibration. The differential equations are solved in closed analytical form when the free vibratory motion is harmonic. The dynamic stiffness matrix is then formulated by relating the amplitudes of forces to those of the displacements at the two ends of the beam. Next, the explicit algebraic expressions for the dynamic stiffness elements are derived with the help of symbolic computation. Finally the Wittrick-Williams algorithm is applied as solution technique to solve the free vibration problems of FGBs with uniform cross-section, stepped FGBs and frameworks consisting of FGBs. Some numerical results are validated against published results, but in the absence of published results for frameworks containing FGBs, consistency checks on the reliability of results are performed. The paper closes with discussion of results and conclusions.

  15. The suggestion of droplets generation prevention method of CNx coating by ion beam assisted deposition

    International Nuclear Information System (INIS)

    Yagi, Yuji; Tokoroyama, Takayuki; Kousaka, Hiroyuki; Umehara, Noritsugu; Fuwa, Yoshio; Manabe, Kazuyoshi

    2013-01-01

    It has been reported that the carbon nitride (CNx) coating was the super-low friction in which friction coefficient was less than 0.01, and it attracts attention as a high wear resistance and low friction material. When synthesizing a CNx coating with Ion Beam Assisted Deposition (IBAD) method, it was clear that the small asperities called droplets was generated onto the CNx coating surface with increasing thickness, and these droplets generated high friction. Therefore, it is necessary to clarify droplets generation mechanism to reduce droplets. To establish optimal coating conditions for controlling droplets were clarified by paying attention to the energy of an electron beam and the shape of a carbon target. First of all, 300 nm thickness CNx coatings were synthesized with five different filament current densities to clarify the relationship between the filament current density and droplet heights. Secondly, the effect of carbon target shape on droplets generation was confirmed with normal and processed carbon target. Finally, friction coefficient of these surfaces was measured by friction tests under PAO lubrication. (author)

  16. Application of adjusted subpixel method (ASM) in HRCT measurements of the bronchi in bronchial asthma patients and healthy individuals.

    Science.gov (United States)

    Mincewicz, Grzegorz; Rumiński, Jacek; Krzykowski, Grzegorz

    2012-02-01

    Recently, we described a model system which included corrections of high-resolution computed tomography (HRCT) bronchial measurements based on the adjusted subpixel method (ASM). To verify the clinical application of ASM by comparing bronchial measurements obtained by means of the traditional eye-driven method, subpixel method alone and ASM in a group comprised of bronchial asthma patients and healthy individuals. The study included 30 bronchial asthma patients and the control group comprised of 20 volunteers with no symptoms of asthma. The lowest internal and external diameters of the bronchial cross-sections (ID and ED) and their derivative parameters were determined in HRCT scans using: (1) traditional eye-driven method, (2) subpixel technique, and (3) ASM. In the case of the eye-driven method, lower ID values along with lower bronchial lumen area and its percentage ratio to total bronchial area were basic parameters that differed between asthma patients and healthy controls. In the case of the subpixel method and ASM, both groups were not significantly different in terms of ID. Significant differences were observed in values of ED and total bronchial area with both parameters being significantly higher in asthma patients. Compared to ASM, the eye-driven method overstated the values of ID and ED by about 30% and 10% respectively, while understating bronchial wall thickness by about 18%. Results obtained in this study suggest that the traditional eye-driven method of HRCT-based measurement of bronchial tree components probably overstates the degree of bronchial patency in asthma patients. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  17. Diaphragm flange and method for lowering particle beam impedance at connected beam tubes of a particle accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Biallas, George Herman

    2017-07-04

    A diaphragm flange for connecting the tubes in a particle accelerator while minimizing beamline impedance. The diaphragm flange includes an outer flange and a thin diaphragm integral with the outer flange. Bolt holes in the outer flange provide a means for bolting the diaphragm flange to an adjacent flange or beam tube having a mating bolt-hole pattern. The diaphragm flange includes a first surface for connection to the tube of a particle accelerator beamline and a second surface for connection to a CF flange. The second surface includes a recessed surface therein and a knife-edge on the recessed surface. The diaphragm includes a thickness that enables flexing of the integral diaphragm during assembly of beamline components. The knife-edge enables compression of a soft metal gasket to provide a leak-tight seal.

  18. Comparison of two methods of therapy level calibration at 60Co gamma beams

    International Nuclear Information System (INIS)

    Bjerke, H.; Jaervinen, H.; Grimbergen, T.W.M.; Grindborg, J.E.; Chauvenet, B.; Czap, L.; Ennow, K.; Moretti, C.; Rocha, P.

    1998-01-01

    The accuracy and traceability of the calibration of radiotherapy dosimeters is of great concern to those involved in the delivery of radiotherapy. It has been proposed that calibration should be carried out directly in terms of absorbed dose to water, instead of using the conventional and widely applied quantity of air kerma. In this study, the faithfulness in disseminating standards of both air kerma and absorbed dose to water were evaluated, through comparison of both types of calibration for three types of commonly used radiotherapy dosimeters at 60 Co gamma beams at a few secondary and primary standard dosimetry laboratories (SSDLs and PSDLs). A supplementary aim was to demonstrate the impact which the change in the method of calibration would have on clinical dose measurements at the reference point. Within the estimated uncertainties, both the air kerma and absorbed dose to water calibration factors obtained at different laboratories were regarded as consistent. As might be expected, between the SSDLs traceable to the same PSDL the observed differences were smaller (less than 0.5%) than between PSDLs or SSDLs traceable to different PSDLs (up to 1.5%). This can mainly be attributed to the reported differences between the primary standards. The calibration factors obtained by the two methods differed by up to about 1.5% depending on the primary standards involved and on the parameters of calculation used for 60 Co gamma radiation. It is concluded that this discrepancy should be settled before the new method of calibration at 60 Co gamma beams in terms of absorbed dose to water is taken into routine use. (author)

  19. Comparison of two methods of therapy level calibration at 60Co gamma beams

    International Nuclear Information System (INIS)

    Bjerke, H; Jaervinen, H; Grimbergen, T W M; Grindborg, J-E; Chauvenet, B; Czap, L; Ennow, K; Moretti, C; Rocha, P

    1998-01-01

    The accuracy and traceability of the calibration of radiotherapy dosimeters is of great concern to those involved in the delivery of radiotherapy. It has been proposed that calibration should be carried out directly in terms of absorbed dose to water, instead of using the conventional and widely applied quantity of air kerma. In this study, the faithfulness in disseminating standards of both air kerma and absorbed dose to water were evaluated, through comparison of both types of calibration for three types of commonly used radiotherapy dosimeters at 60 Co gamma beams at a few secondary and primary standard dosimetry laboratories (SSDLs and PSDLs). A supplementary aim was to demonstrate the impact which the change in the method of calibration would have on clinical dose measurements at the reference point. Within the estimated uncertainties, both the air kerma and absorbed dose to water calibration factors obtained at different laboratories were regarded as consistent. As might be expected, between the SSDLs traceable to the same PSDL the observed differences were smaller (less than 0.5%) than between PSDLs or SSDLs traceable to different PSDLs (up to 1.5%). This can mainly be attributed to the reported differences between the primary standards. The calibration factors obtained by the two methods differed by up to about 1.5% depending on the primary standards involved and on the parameters of calculation used for 60 Co gamma radiation. It is concluded that this discrepancy should be settled before the new method of calibration at 60 Co gamma beams in terms of absorbed dose to water is taken into routine use

  20. Deflection monitoring for a box girder based on a modified conjugate beam method

    Science.gov (United States)

    Chen, Shi-Zhi; Wu, Gang; Xing, Tuo

    2017-08-01

    After several years of operation, a box girder bridge would commonly experience excessive deflection, which endangers the bridge’s life span as well as the safety of vehicles travelling on it. In order to avoid potential risks, it is essential to constantly monitor the defection of box girders. However, currently, the direct deflection monitoring methods are limited by the complicated environments beneath the bridges, such as rivers or other traffic lanes, which severely impede the layouts of the sensors. The other indirect deflection monitoring methods mostly do not thoroughly consider the inherent shear lag effect and shear deformation in the box girder, resulting in a rather large error. Under these circumstances, a deflection monitoring method suiting box girders is proposed in this article, based on the conjugate beam method and distributed long-gauge fibre Bragg grating (FBG) sensor. A lab experiment was conducted to verify the reliability and feasibility of this method under practical application. Further, the serviceability under different span-depth ratios and web thicknesses was examined through a finite element model.

  1. Empirical comparison of four baseline covariate adjustment methods in analysis of continuous outcomes in randomized controlled trials

    Directory of Open Access Journals (Sweden)

    Zhang S

    2014-07-01

    Full Text Available Shiyuan Zhang,1 James Paul,2 Manyat Nantha-Aree,2 Norman Buckley,2 Uswa Shahzad,2 Ji Cheng,2 Justin DeBeer,5 Mitchell Winemaker,5 David Wismer,5 Dinshaw Punthakee,5 Victoria Avram,5 Lehana Thabane1–41Department of Clinical Epidemiology and Biostatistics, 2Department of Anesthesia, McMaster University, Hamilton, ON, Canada; 3Biostatistics Unit/Centre for Evaluation of Medicines, St Joseph's Healthcare - Hamilton, Hamilton, ON, Canada; 4Population Health Research Institute, Hamilton Health Science/McMaster University, 5Department of Surgery, Division of Orthopaedics, McMaster University, Hamilton, ON, CanadaBackground: Although seemingly straightforward, the statistical comparison of a continuous variable in a randomized controlled trial that has both a pre- and posttreatment score presents an interesting challenge for trialists. We present here empirical application of four statistical methods (posttreatment scores with analysis of variance, analysis of covariance, change in scores, and percent change in scores, using data from a randomized controlled trial of postoperative pain in patients following total joint arthroplasty (the Morphine COnsumption in Joint Replacement Patients, With and Without GaBapentin Treatment, a RandomIzed ControlLEd Study [MOBILE] trials.Methods: Analysis of covariance (ANCOVA was used to adjust for baseline measures and to provide an unbiased estimate of the mean group difference of the 1-year postoperative knee flexion scores in knee arthroplasty patients. Robustness tests were done by comparing ANCOVA with three comparative methods: the posttreatment scores, change in scores, and percentage change from baseline.Results: All four methods showed similar direction of effect; however, ANCOVA (-3.9; 95% confidence interval [CI]: -9.5, 1.6; P=0.15 and the posttreatment score (-4.3; 95% CI: -9.8, 1.2; P=0.12 method provided the highest precision of estimate compared with the change score (-3.0; 95% CI: -9.9, 3.8; P=0

  2. Method of measuring a profile of the density of charged particles in a particle beam

    International Nuclear Information System (INIS)

    Hyman, L.G.; Jankowski, D.J.

    1975-01-01

    A profile of the relative density of charged particles in a beam is obtained by disposing a number of rods parallel to each other in a plane perpendicular to the beam and shadowing the beam. A second number of rods is disposed perpendicular to the first rods in a plane perpendicular to the beam and also shadowing the beam. Irradiation of the rods by the beam of charged particles creates radioactive isotopes in a quantity proportional to the number of charged particles incident upon the rods. Measurement of the radioactivity of each of the rods provides a measure of the quantity of radioactive material generated thereby and, together with the location of the rods, provides information sufficient to identify a profile of the density of charged particles in the beam

  3. Method and split cavity oscillator/modulator to generate pulsed particle beams and electromagnetic fields

    Science.gov (United States)

    Clark, M. Collins; Coleman, P. Dale; Marder, Barry M.

    1993-01-01

    A compact device called the split cavity modulator whose self-generated oscillating electromagnetic field converts a steady particle beam into a modulated particle beam. The particle beam experiences both signs of the oscillating electric field during the transit through the split cavity modulator. The modulated particle beam can then be used to generate microwaves at that frequency and through the use of extractors, high efficiency extraction of microwave power is enabled. The modulated beam and the microwave frequency can be varied by the placement of resistive wires at nodes of oscillation within the cavity. The short beam travel length through the cavity permit higher currents because both space charge and pinching limitations are reduced. The need for an applied magnetic field to control the beam has been eliminated.

  4. Laser systems configured to output a spectrally-consolidated laser beam and related methods

    Science.gov (United States)

    Koplow, Jeffrey P [San Ramon, CA

    2012-01-10

    A laser apparatus includes a plurality of pumps each of which is configured to emit a corresponding pump laser beam having a unique peak wavelength. The laser apparatus includes a spectral beam combiner configured to combine the corresponding pump laser beams into a substantially spatially-coherent pump laser beam having a pump spectrum that includes the unique peak wavelengths, and first and second selectively reflective elements spaced from each other to define a lasing cavity including a lasing medium therein. The lasing medium generates a plurality of gain spectra responsive to absorbing the pump laser beam. Each gain spectrum corresponds to a respective one of the unique peak wavelengths of the substantially spatially-coherent pump laser beam and partially overlaps with all other ones of the gain spectra. The reflective elements are configured to promote emission of a laser beam from the lasing medium with a peak wavelength common to each gain spectrum.

  5. A novel method and error analysis for beam optics measurements and corrections at the Large Hadron Collider

    Energy Technology Data Exchange (ETDEWEB)

    Langner, Andy Sven

    2017-02-03

    The Large Hadron Collider (LHC) is currently the world's largest particle accelerator with the highest center of mass energy in particle collision experiments. The control of the particle beam focusing is essential for the performance reach of such an accelerator. For the characterization of the focusing properties at the LHC, turn-by-turn beam position data is simultaneously recorded at numerous measurement devices (BPMs) along the accelerator, while an oscillation is excited on the beam. A novel analysis method for these measurements (N-BPM method) is developed here, which is based on a detailed analysis of systematic and statistical error sources and their correlations. It has been applied during the commissioning of the LHC for operation at an unprecedented energy of 6.5TeV. In this process a stronger focusing than its design specifications has been achieved. This results in smaller transverse beam sizes at the collision points and allows for a higher rate of particle collisions. For the derivation of the focusing parameters at many synchrotron light sources, the change of the beam orbit is observed, which is induced by deliberate changes of magnetic fields (orbit response matrix). In contrast, the analysis of turn-by-turn beam position measurements is for many of these machines less precise due to the distance between two BPMs. The N-BPM method overcomes this limitation by allowing to include the measurement data from more BPMs in the analysis. It has been applied at the ALBA synchrotron light source and compared to the orbit response method. The significantly faster measurement with the N-BPM method is a considerable advantage in this case. Finally, an outlook is given to the challenges which lie ahead for the control of the beam focusing at the HL-LHC, which is a future major upgrade of the LHC.

  6. Laser beam uniformity and stability using homogenizer-based fiber optic launch method: square core fiber delivery

    Science.gov (United States)

    Lizotte, Todd E.

    2011-03-01

    Over the years, technological achievements within the laser medical diagnostic, treatment, and therapy markets have led to ever increasing requirements for greater control of critical laser beam parameters. Increased laser power/energy stabilization, temporal and spatial beam shaping and flexible laser beam delivery systems with ergonomic focusing or imaging lens systems are sought by leading medical laser system producers. With medical procedures that utilize laser energy, there is a constant emphasis on reducing adverse effects that come about by the laser itself or its optical system, but even when these variables are well controlled the medical professional will still need to deal with the multivariate nature of the human body. Focusing on the variables that can be controlled, such as accurate placement of the laser beam where it will expose a surface being treated as well as laser beam shape and uniformity is critical to minimizing adverse conditions. This paper covers the use of fiber optic beam delivery as a means of defining the beam shape (intensity/power distribution uniformity) at the target plane as well as the use of fiber delivery as a means to allow more flexible articulation of the laser beam over the surface being treated. The paper will present a new concept of using a square core fiber beam delivery design utilizing a unique micro lens array (MLA) launch method that improves the overall stability of the system, by minimizing the impact of the laser instability. The resulting performance of the prototype is presented to demonstrate its stability in comparison to simple lens launch techniques, with an emphasis on homogenization and articulated fiber delivery.

  7. Silicon-based photonic crystals fabricated using proton beam writing combined with electrochemical etching method.

    Science.gov (United States)

    Dang, Zhiya; Breese, Mark Bh; Recio-Sánchez, Gonzalo; Azimi, Sara; Song, Jiao; Liang, Haidong; Banas, Agnieszka; Torres-Costa, Vicente; Martín-Palma, Raúl José

    2012-07-23

    A method for fabrication of three-dimensional (3D) silicon nanostructures based on selective formation of porous silicon using ion beam irradiation of bulk p-type silicon followed by electrochemical etching is shown. It opens a route towards the fabrication of two-dimensional (2D) and 3D silicon-based photonic crystals with high flexibility and industrial compatibility. In this work, we present the fabrication of 2D photonic lattice and photonic slab structures and propose a process for the fabrication of 3D woodpile photonic crystals based on this approach. Simulated results of photonic band structures for the fabricated 2D photonic crystals show the presence of TE or TM gap in mid-infrared range.

  8. A comparison of two methods for estimating the technical costs of external beam radiation therapy

    International Nuclear Information System (INIS)

    Hayman, James A.; Lash, Kathy A.; Tao, May L.; Halman, Marc A.

    2000-01-01

    Purpose: To accurately assess the cost-effectiveness of treatment with external beam radiation, it is necessary to have accurate estimates of its cost. One of the most common methods for estimating technical costs has been to convert Medicare charges into costs using Medicare Cost-to-Charge Ratios (CCR). More recently, health care organizations have begun to invest in sophisticated cost-accounting systems (CAS) that are capable of providing procedure-specific cost estimates. The purpose of this study was to examine whether these competing approaches result in similar cost estimates for four typical courses of external beam radiation therapy (EBRT). Methods and Materials: Technical costs were estimated for the following treatment courses: 1) a palliative 'simple' course of 10 fractions using a single field without blocks; 2) a palliative 'complex' course of 10 fractions using two opposed fields with custom blocks; 3) a curative course of 30 fractions for breast cancer using tangent fields followed by an electron beam boost; and 4) a curative course of 35 fractions for prostate cancer using CT-planning and a 4-field technique. Costs were estimated using the CCR approach by multiplying the number of units of each procedure billed by its Medicare charge and CCR and then summing these costs. Procedure-specific cost estimates were obtained from a cost-accounting system, and overall costs were then estimated for the CAS approach by multiplying the number of units billed by the appropriate unit cost estimate and then summing these costs. All costs were estimated using data from 1997. The analysis was also repeated using data from another academic institution to estimate their costs using the CCR and CAS methods, as well as the appropriate relative value units (RVUs) and conversion factor from the 1997 Medicare Fee Schedule to estimate Medicare reimbursement for the four treatment courses. Results: The estimated technical costs for the CCR vs. CAS approaches for the four

  9. Method of phase space beam dilution utilizing bounded chaos generated by rf phase modulation

    Directory of Open Access Journals (Sweden)

    Alfonse N. Pham

    2015-12-01

    Full Text Available This paper explores the physics of chaos in a localized phase-space region produced by rf phase modulation applied to a double rf system. The study can be exploited to produce rapid particle bunch broadening exhibiting longitudinal particle distribution uniformity. Hamiltonian models and particle-tracking simulations are introduced to understand the mechanism and applicability of controlled particle diffusion. When phase modulation is applied to the double rf system, regions of localized chaos are produced through the disruption and overlapping of parametric resonant islands and configured to be bounded by well-behaved invariant tori to prevent particle loss. The condition of chaoticity and the degree of particle dilution can be controlled by the rf parameters. The method has applications in alleviating adverse space-charge effects in high-intensity beams, particle bunch distribution uniformization, and industrial radiation-effects experiments.

  10. Method of improving photoelectric efficiency for laser power beaming based on photovoltaic cell layout optimization

    Science.gov (United States)

    Li, Beibei; Li, Xiaojiang

    2017-02-01

    In accordance with the high impact of the uneven distribution of laser beam power on the photovoltaic efficiency of photovoltaic cell (PV) array, a method based on PV layout optimization is proposed to improve the photovoltaic efficiency. First of all, a mathematical model of series-parallel PV array is built, and by analyzing the influencing factors on photovoltaic efficiency, the idea and scheme to improve the photovoltaic efficiency based on PV layout optimization is provided; then, the MATLAB/Simulink simulation tool is used to simulate the effects of improving photoelectric efficiency. The simulation results show that compared to the traditional PV array, the optimized PV array can obtain higher photovoltaic efficiency, and compared to the situation with uneven temperature distribution, the array efficiency has higher efficiency under even temperature distribution.

  11. Efficient design of a truss beam by applying first order optimization method

    Science.gov (United States)

    Fedorik, Filip

    2013-10-01

    Applications of optimization procedures in structural designs are widely discussed problems, which are caused by currently still-increasing demands on structures. Using of optimization methods in efficient designs passes through great development, especially in duplicate production where even small savings might lead to considerable reduction of total costs. The presented paper deals with application and analysis of the First Order optimization technique, which is implemented in the Design Optimization module that uses the main features of multi-physical FEM program ANSYS, in steel truss-beam design. Constraints of the design are stated by EN 1993 Eurocode 3, for uniform compression forces in compression members and tensile resistance moments in tension members. Furthermore, a minimum frequency of the first natural modal shape of the structure is determined. The aim of the solution is minimizing the weight of the structure by changing members' cross-section properties.

  12. A method for selection of beam angles robust to intra-fractional motion in proton therapy of lung cancer

    DEFF Research Database (Denmark)

    Casares-Magaz, Oscar; Toftegaard, Jakob; Muren, Ludvig P.

    2014-01-01

    WEPL variations caused by breathing-induced motion for all possible beam angles in a series of lung cancer patients. By studying the association between measures for WEPL variation and breathing-induced target dose degradation we aimed to develop and explore a tool to identify beam angles...... that are robust to patient-specific patterns of intra-fractional motion. Material and methods. Using four-dimensional computed tomography (4DCT) images of three lung cancer patients we evaluated the impact of the WEPL changes on target dose coverage for a series of coplanar single-beam plans. The plans were...... reduction was associated with the mean difference between the WEPL and the phase-averaged WEPL computed for all beam rays across all possible gantry-couch angle combinations. Results. The gantry-couch angle maps showed areas of both high and low WEPL variation, with overall quite similar patterns yet...

  13. Analysis of Beams with Transversal Gradations of the Young's Modulus and Variable Depths by the Meshless Method

    Directory of Open Access Journals (Sweden)

    Sátor Ladislav

    2014-03-01

    Full Text Available A numerical analysis based on the meshless local Petrov- Galerkin (MLPG method is proposed for a functionally graded material FGM (FGMfunctionally graded material beam. The planar bending of the beam is considered with a transversal gradation of Young's modulus and a variable depth of the beam. The collocation formulation is constructed from the equilibrium equations for the mechanical fields. Dirac's delta function is employed as a test function in the derivation of a strong formulation. The Moving Least Squares (MLS approximation technique is applied for an approximation of the spatial variations of all the physical quantities. An investigation of the accuracy, the convergence of the accuracy, the computational efficiency and the effect of the level of the gradation of Young's modulus on the behaviour of coupled mechanical fields is presented in various boundary value problems for a rectangular beam with a functionally graded Young's modulus.

  14. Prior event rate ratio adjustment: numerical studies of a statistical method to address unrecognized confounding in observational studies.

    Science.gov (United States)

    Yu, Menggang; Xie, Dawei; Wang, Xingmei; Weiner, Mark G; Tannen, Richard L

    2012-05-01

    The purpose of this study was to evaluate a statistical method, prior event rate ratio (PERR) adjustment, and an alternative, PERR-ALT, both of which have the potential to overcome "unmeasured confounding," both analytically and via simulation. Formulae were derived for the target estimates of both PERR methods, which were compared with results from simulations to ensure their validity. In addition to the theoretical insights gained, relative biases of both PERR methods for estimating exposure effects were also investigated via simulation studies and compared empirically with electronic medical record database study results. Theoretical derivations closely matched simulated results. In simulation studies, both PERR methods significantly reduce bias from unmeasured confounding compared with the standard Cox model. When there is no interaction between unmeasured confounders and time intervals, the estimate from PERR-ALT is unbiased, whereas the estimate from PERR has well-controlled relative bias. When interactions exist, relative biases tend to increase but not greatly, especially when the exposure effect is relatively large in comparison with the interaction effects. When the event rate is low and the sample size is limited, PERR is more computationally stable than PERR-ALT. In empiric study comparisons with randomized controlled trials, both PERR methods show potential to reduce bias from the standard Cox model similarly when unmeasured confounding is present. Extensive simulation studies and theoretical derivation show that PERR-based methods may reduce bias from unmeasured confounders when the exposure effect is relatively large in comparison with confounder-exposure interaction. The rare study event situation warrants further investigation. Copyright © 2012 John Wiley & Sons, Ltd.

  15. A level set method for cupping artifact correction in cone-beam CT

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Shipeng; Li, Haibo; Ge, Qi [College of Telecommunications and Information Engineering, Nanjing University of Posts and Telecommunications, Nanjing, Jiangsu 210003 (China); Li, Chunming, E-mail: li-chunming@hotmail.com [School of Electronic Engineering, University of Electronic Science and Technology of China (UESTC), Chengdu, Sichuan 611731 (China)

    2015-08-15

    Purpose: To reduce cupping artifacts and improve the contrast-to-noise ratio in cone-beam computed tomography (CBCT). Methods: A level set method is proposed to reduce cupping artifacts in the reconstructed image of CBCT. The authors derive a local intensity clustering property of the CBCT image and define a local clustering criterion function of the image intensities in a neighborhood of each point. This criterion function defines an energy in terms of the level set functions, which represent a segmentation result and the cupping artifacts. The cupping artifacts are estimated as a result of minimizing this energy. Results: The cupping artifacts in CBCT are reduced by an average of 90%. The results indicate that the level set-based algorithm is practical and effective for reducing the cupping artifacts and preserving the quality of the reconstructed image. Conclusions: The proposed method focuses on the reconstructed image without requiring any additional physical equipment, is easily implemented, and provides cupping correction through a single-scan acquisition. The experimental results demonstrate that the proposed method successfully reduces the cupping artifacts.

  16. Power secant method applied to natural frequency extraction of Timoshenko beam structures

    Directory of Open Access Journals (Sweden)

    C.A.N. Dias

    Full Text Available This work deals with an improved plane frame formulation whose exact dynamic stiffness matrix (DSM presents, uniquely, null determinant for the natural frequencies. In comparison with the classical DSM, the formulation herein presented has some major advantages: local mode shapes are preserved in the formulation so that, for any positive frequency, the DSM will never be ill-conditioned; in the absence of poles, it is possible to employ the secant method in order to have a more computationally efficient eigenvalue extraction procedure. Applying the procedure to the more general case of Timoshenko beams, we introduce a new technique, named "power deflation", that makes the secant method suitable for the transcendental nonlinear eigenvalue problems based on the improved DSM. In order to avoid overflow occurrences that can hinder the secant method iterations, limiting frequencies are formulated, with scaling also applied to the eigenvalue problem. Comparisons with results available in the literature demonstrate the strength of the proposed method. Computational efficiency is compared with solutions obtained both by FEM and by the Wittrick-Williams algorithm.

  17. A comparison of two methods for estimating the technical costs of external beam radiation therapy.

    Science.gov (United States)

    Hayman, J A; Lash, K A; Tao, M L; Halman, M A

    2000-05-01

    To accurately assess the cost-effectiveness of treatment with external beam radiation, it is necessary to have accurate estimates of its cost. One of the most common methods for estimating technical costs has been to convert Medicare charges into costs using Medicare Cost-to-Charge Ratios (CCR). More recently, health care organizations have begun to invest in sophisticated cost-accounting systems (CAS) that are capable of providing procedure-specific cost estimates. The purpose of this study was to examine whether these competing approaches result in similar cost estimates for four typical courses of external beam radiation therapy (EBRT). Technical costs were estimated for the following treatment courses: 1) a palliative "simple" course of 10 fractions using a single field without blocks; 2) a palliative "complex" course of 10 fractions using two opposed fields with custom blocks; 3) a curative course of 30 fractions for breast cancer using tangent fields followed by an electron beam boost; and 4) a curative course of 35 fractions for prostate cancer using CT-planning and a 4-field technique. Costs were estimated using the CCR approach by multiplying the number of units of each procedure billed by its Medicare charge and CCR and then summing these costs. Procedure-specific cost estimates were obtained from a cost-accounting system, and overall costs were then estimated for the CAS approach by multiplying the number of units billed by the appropriate unit cost estimate and then summing these costs. All costs were estimated using data from 1997. The analysis was also repeated using data from another academic institution to estimate their costs using the CCR and CAS methods, as well as the appropriate relative value units (RVUs) and conversion factor from the 1997 Medicare Fee Schedule to estimate Medicare reimbursement for the four treatment courses. The estimated technical costs for the CCR vs. CAS approaches for the four treatment courses were as follows

  18. Branch switching at Hopf bifurcation analysis via asymptotic numerical method: Application to nonlinear free vibrations of rotating beams

    Science.gov (United States)

    Bekhoucha, Ferhat; Rechak, Said; Duigou, Laëtitia; Cadou, Jean-Marc

    2015-05-01

    This paper deals with the computation of backbone curves bifurcated from a Hopf bifurcation point in the framework of nonlinear free vibrations of a rotating flexible beams. The intrinsic and geometrical equations of motion for anisotropic beams subjected to large displacements are used and transformed with Galerkin and harmonic balance methods to one quadratic algebraic equation involving one parameter, the pulsation. The latter is treated with the asymptotic numerical method using Padé approximants. An algorithm, equivalent to the Lyapunov-Schmidt reduction is proposed, to compute the bifurcated branches accurately from a Hopf bifurcation point, with singularity of co-rank 2, related to a conservative and gyroscopic dynamical system steady state, toward a nonlinear periodic state. Numerical tests dealing with clamped, isotropic and composite, rotating beams show the reliability of the proposed method reinforced by accurate results.

  19. Crack identification method in beam-like structures using changes in experimentally measured frequencies and Particle Swarm Optimization

    Science.gov (United States)

    Khatir, Samir; Dekemele, Kevin; Loccufier, Mia; Khatir, Tawfiq; Abdel Wahab, Magd

    2018-02-01

    In this paper, a technique is presented for the detection and localization of an open crack in beam-like structures using experimentally measured natural frequencies and the Particle Swarm Optimization (PSO) method. The technique considers the variation in local flexibility near the crack. The natural frequencies of a cracked beam are determined experimentally and numerically using the Finite Element Method (FEM). The optimization algorithm is programmed in MATLAB. The algorithm is used to estimate the location and severity of a crack by minimizing the differences between measured and calculated frequencies. The method is verified using experimentally measured data on a cantilever steel beam. The Fourier transform is adopted to improve the frequency resolution. The results demonstrate the good accuracy of the proposed technique.

  20. Assessment of Structural Behavior of Non-corroded and Corroded RCC Beams Using Finite Element Method

    Directory of Open Access Journals (Sweden)

    Anand Parande

    2008-09-01

    Full Text Available A three dimensional finite element model is developed to examine the structural behaviour of corroded reinforced concrete beam and non corroded reinforced concrete beam. Non linear finite element analysis is performed using the ANSYS program. SOLID 65, LINK 8 element represent concrete and discrete reinforcing steel bars, based on each component actual characteristics, non linear material properties are defined for both elements. The effect of corrosion in reinforced concrete is studied by finite element analysis; an approach is developed to model the corrosion product expansion causing concrete cover cracking for this, beam has been modeled using ANSYS and using this data the beam has been casted with M20 concrete after 28 days the beam will be tested for flexural strength. The comparison between ANSYS prediction and field data are made in terms of deflection, stress, strain, bond strength and crack pattern of concrete beam.

  1. A new method for x-ray scatter correction: first assessment on a cone-beam CT experimental setup

    Energy Technology Data Exchange (ETDEWEB)

    Rinkel, J [CEA-LETI MINATEC, Division of Micro Technologies for Biology and Healthcare, 38054 Grenoble Cedex 09 (France); Gerfault, L [CEA-LETI MINATEC, Division of Micro Technologies for Biology and Healthcare, 38054 Grenoble Cedex 09 (France); Esteve, F [INSERM U647-RSRM, ESRF, BP200, 38043 Grenoble Cedex 09 (France); Dinten, J-M [CEA-LETI MINATEC, Division of Micro Technologies for Biology and Healthcare, 38054 Grenoble Cedex 09 (France)

    2007-08-07

    Cone-beam computed tomography (CBCT) enables three-dimensional imaging with isotropic resolution and a shorter acquisition time compared to a helical CT scanner. Because a larger object volume is exposed for each projection, scatter levels are much higher than in collimated fan-beam systems, resulting in cupping artifacts, streaks and quantification inaccuracies. In this paper, a general method to correct for scatter in CBCT, without supplementary on-line acquisition, is presented. This method is based on scatter calibration through off-line acquisition combined with on-line analytical transformation based on physical equations, to adapt calibration to the object observed. The method was tested on a PMMA phantom and on an anthropomorphic thorax phantom. The results were validated by comparison to simulation for the PMMA phantom and by comparison to scans obtained on a commercial multi-slice CT scanner for the thorax phantom. Finally, the improvements achieved with the new method were compared to those obtained using a standard beam-stop method. The new method provided results that closely agreed with the simulation and with the conventional CT scanner, eliminating cupping artifacts and significantly improving quantification. Compared to the beam-stop method, lower x-ray doses and shorter acquisition times were needed, both divided by a factor of 9 for the same scatter estimation accuracy.

  2. Stress-Based Finite Element Methods for Dynamics Analysis of Euler-Bernoulli Beams with Various Boundary Conditions

    Directory of Open Access Journals (Sweden)

    Majid Gholampour

    Full Text Available Abstract In this research, two stress-based finite element methods including the curvature-based finite element method (CFE and the curvature-derivative-based finite element method (CDFE are developed for dynamics analysis of Euler-Bernoulli beams with different boundary conditions. In CFE, the curvature distribution of the Euler-Bernoulli beams is approximated by its nodal curvatures then the displacement distribution is obtained by its integration. In CDFE, the displacement distribution is approximated in terms of nodal curvature derivatives by integration of the curvature derivative distribution. In the introduced methods, compared with displacement-based finite element method (DFE, not only the required number of degrees of freedom is reduced, but also the continuity of stress at nodal points is satisfied. In this paper, the natural frequencies of beams with different type of boundary conditions are obtained using both CFE and CDFE methods. Furthermore, some numerical examples for the static and dynamic response of some beams are solved and compared with those obtained by DFE method.

  3. Convexity Adjustments

    DEFF Research Database (Denmark)

    M. Gaspar, Raquel; Murgoci, Agatha

    2010-01-01

    A convexity adjustment (or convexity correction) in fixed income markets arises when one uses prices of standard (plain vanilla) products plus an adjustment to price nonstandard products. We explain the basic and appealing idea behind the use of convexity adjustments and focus on the situations...

  4. Method and system for automatically correcting aberrations of a beam of charged particles

    International Nuclear Information System (INIS)

    1975-01-01

    The location of a beam of charged particles within a deflection field is determined by its orthogonal deflection voltages. With the location of the beam in the field, correction currents are supplied to a focus coil and to each of a pair of stigmator coils to correct for change of focal length and astigmatism due to the beam being deflected away from the center of its deflection field

  5. Development of automatic control method for cryopump system for JT-60 neutral beam injector

    International Nuclear Information System (INIS)

    Shibanuma, Kiyoshi; Akino, Noboru; Dairaku, Masayuki; Ohuchi, Yutaka; Shibata, Takemasa

    1991-10-01

    A cryopump system for JT-60 neutral beam injector (NBI) is composed of 14 cryopumps with the largest total pumping speed of 20000 m 3 /s in the world, which are cooled by liquid helium through a long-distance liquid helium transferline of about 500 m from a helium refrigerator with the largest capacity of 3000 W at 3.6 K in Japan. An automatic control method of the cryopump system has been developed and tested. Features of the automatic control method are as follows. 1) Suppression control of the thermal imbalance in cooling-down of the 14 cryopumps. 2) Stable cooling control of the cryopump due to liquid helium supply to six cryopanels by natural circulation in steady-state mode. 3) Stable liquid helium supply control for the cryopumps from the liquid helium dewar in all operation modes of the cryopumps, considering the helium quantities held in respective components of the closed helium loop. 4) Stable control of the helium refrigerator for the fluctuation in thermal load from the cryopumps and the change of operation mode of the cryopumps. In the automatic operation of the cryopump system by the newly developed control method, the cryopump system including the refrigerator was stably operated for all operation modes of the cryopumps, so that the cool-down of 14 cryopumps was completed in 16 hours from the start of cool-down of the system and the cryopumps was stably cooled by natural circulation cooling in steady-state mode. (author)

  6. Inelastic analysis of piping systems. A beam-type method for creep and plasticity

    International Nuclear Information System (INIS)

    Roche, R.L.; Hoffmann, A.; Millard, A.

    1979-01-01

    Since many years, piping systems are designed and calculated under elasticity assumptions, using a beam-type method. Thus, the analysis of large systems may be performed at a relatively low cost, using a finite element program. However such a method can not account for inelastic phenomena like plastic deformations or creep. The application of refined three-dimensional shell type method is possible for local components such as curved sections but leads to prohibitive costs for complete piping systems. Therefore simplified methods have been developed, based on a 'global plasticity or creep model'. Following the conventional elastic approach, the pipe element is characterized by variables associated with the center line in the following way: generalized stresses are obtained by integration of local stresses giving way to hoop and tension stresses and to bending and torsional moments; the conjugated strains are identified with uniform hoop and longitudinal strains and variations in neutral axis curvatuves. For plasticity problems, the yield surface is defined by a diagonal quadratic function in terms of the generalized stresses and work hardening parameters. By addition of the Hill's principle and a hardening rule, the formulation is similar to the one commonly used in finite element method. Geometric non linearity due to important deformations of the cross section (often termed 'ovalization') may be treated simultaneously with material non linearity. For this purpose the displacement normal to the pipe surface is represented by trigonometric series expansion, the coefficients of which are determined by minimizing the strain energy over the cross section. The method presented is believed to be a simple economical and accurate tool, for dimensioning computations of large piping systems

  7. Impact of urine concentration adjustment method on associations between urine metals and estimated glomerular filtration rates (eGFR) in adolescents

    International Nuclear Information System (INIS)

    Weaver, Virginia M.; Vargas, Gonzalo García; Silbergeld, Ellen K.; Rothenberg, Stephen J.; Fadrowski, Jeffrey J.; Rubio-Andrade, Marisela; Parsons, Patrick J.; Steuerwald, Amy J.

    2014-01-01

    Positive associations between urine toxicant levels and measures of glomerular filtration rate (GFR) have been reported recently in a range of populations. The explanation for these associations, in a direction opposite that of traditional nephrotoxicity, is uncertain. Variation in associations by urine concentration adjustment approach has also been observed. Associations of urine cadmium, thallium and uranium in models of serum creatinine- and cystatin-C-based estimated GFR (eGFR) were examined using multiple linear regression in a cross-sectional study of adolescents residing near a lead smelter complex. Urine concentration adjustment approaches compared included urine creatinine, urine osmolality and no adjustment. Median age, blood lead and urine cadmium, thallium and uranium were 13.9 years, 4.0 μg/dL, 0.22, 0.27 and 0.04 g/g creatinine, respectively, in 512 adolescents. Urine cadmium and thallium were positively associated with serum creatinine-based eGFR only when urine creatinine was used to adjust for urine concentration (β coefficient=3.1 mL/min/1.73 m 2 ; 95% confidence interval=1.4, 4.8 per each doubling of urine cadmium). Weaker positive associations, also only with urine creatinine adjustment, were observed between these metals and serum cystatin-C-based eGFR and between urine uranium and serum creatinine-based eGFR. Additional research using non-creatinine-based methods of adjustment for urine concentration is necessary. - Highlights: • Positive associations between urine metals and creatinine-based eGFR are unexpected. • Optimal approach to urine concentration adjustment for urine biomarkers uncertain. • We compared urine concentration adjustment methods. • Positive associations observed only with urine creatinine adjustment. • Additional research using non-creatinine-based methods of adjustment needed

  8. Impact of urine concentration adjustment method on associations between urine metals and estimated glomerular filtration rates (eGFR) in adolescents

    Energy Technology Data Exchange (ETDEWEB)

    Weaver, Virginia M., E-mail: vweaver@jhsph.edu [Department of Environmental Health Sciences, Johns Hopkins Bloomberg School of Public Health, Johns Hopkins University, Baltimore, MD (United States); Johns Hopkins University School of Medicine, Baltimore, MD (United States); Welch Center for Prevention, Epidemiology, and Clinical Research, Johns Hopkins Bloomberg School of Public Health, Johns Hopkins University, Baltimore, MD (United States); Vargas, Gonzalo García [Faculty of Medicine, University of Juárez of Durango State, Durango (Mexico); Secretaría de Salud del Estado de Coahuila, Coahuila, México (Mexico); Silbergeld, Ellen K. [Department of Environmental Health Sciences, Johns Hopkins Bloomberg School of Public Health, Johns Hopkins University, Baltimore, MD (United States); Rothenberg, Stephen J. [Instituto Nacional de Salud Publica, Centro de Investigacion en Salud Poblacional, Cuernavaca, Morelos (Mexico); Fadrowski, Jeffrey J. [Johns Hopkins University School of Medicine, Baltimore, MD (United States); Welch Center for Prevention, Epidemiology, and Clinical Research, Johns Hopkins Bloomberg School of Public Health, Johns Hopkins University, Baltimore, MD (United States); Rubio-Andrade, Marisela [Faculty of Medicine, University of Juárez of Durango State, Durango (Mexico); Parsons, Patrick J. [Laboratory of Inorganic and Nuclear Chemistry, Wadsworth Center, New York State Department of Health, Albany, NY (United States); Department of Environmental Health Sciences, School of Public Health, University at Albany, Albany, NY (United States); Steuerwald, Amy J. [Laboratory of Inorganic and Nuclear Chemistry, Wadsworth Center, New York State Department of Health, Albany, NY (United States); and others

    2014-07-15

    Positive associations between urine toxicant levels and measures of glomerular filtration rate (GFR) have been reported recently in a range of populations. The explanation for these associations, in a direction opposite that of traditional nephrotoxicity, is uncertain. Variation in associations by urine concentration adjustment approach has also been observed. Associations of urine cadmium, thallium and uranium in models of serum creatinine- and cystatin-C-based estimated GFR (eGFR) were examined using multiple linear regression in a cross-sectional study of adolescents residing near a lead smelter complex. Urine concentration adjustment approaches compared included urine creatinine, urine osmolality and no adjustment. Median age, blood lead and urine cadmium, thallium and uranium were 13.9 years, 4.0 μg/dL, 0.22, 0.27 and 0.04 g/g creatinine, respectively, in 512 adolescents. Urine cadmium and thallium were positively associated with serum creatinine-based eGFR only when urine creatinine was used to adjust for urine concentration (β coefficient=3.1 mL/min/1.73 m{sup 2}; 95% confidence interval=1.4, 4.8 per each doubling of urine cadmium). Weaker positive associations, also only with urine creatinine adjustment, were observed between these metals and serum cystatin-C-based eGFR and between urine uranium and serum creatinine-based eGFR. Additional research using non-creatinine-based methods of adjustment for urine concentration is necessary. - Highlights: • Positive associations between urine metals and creatinine-based eGFR are unexpected. • Optimal approach to urine concentration adjustment for urine biomarkers uncertain. • We compared urine concentration adjustment methods. • Positive associations observed only with urine creatinine adjustment. • Additional research using non-creatinine-based methods of adjustment needed.

  9. Numerical studies of laser beam propagation with phase screen method using Non-Kolmogorov atmospheric turbulence

    Science.gov (United States)

    Yıldız, Fehmiye; Kurt, Hamza

    2017-09-01

    It is well known that atmospheric turbulence severely limits the applications based on the laser propagation though the atmosphere. The most common disturbances occurring due to the atmospheric turbulence are beam spreading, beam wandering, and scintillation. These effects are continuously changing in response to atmospheric conditions. In this study, we create a Non-Kolmogorov turbulence model which is based on the geometrical optics approximation and the property of Gamma function and integrate with in Gaussian beam analytically. This approach helps us to understand the propagation of the laser beam at different wavelengths in the atmospheric turbulence.

  10. Improvement of GaN epilayer by gradient layer method with molecular-beam epitaxy

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Yen-Liang [Department of Physics, Institute of Material Science and Engineering, Center for Nanoscience and Nanotechnology, National Sun Yat-Sen University, Kaohsiung 80424, Taiwan, ROC (China); Lo, Ikai, E-mail: ikailo@mail.phys.nsysu.edu.tw [Department of Physics, Institute of Material Science and Engineering, Center for Nanoscience and Nanotechnology, National Sun Yat-Sen University, Kaohsiung 80424, Taiwan, ROC (China); Gau, Ming-Hong; Hsieh, Chia-Ho; Sham, Meng-Wei; Pang, Wen-Yuan; Hsu, Yu-Chi [Department of Physics, Institute of Material Science and Engineering, Center for Nanoscience and Nanotechnology, National Sun Yat-Sen University, Kaohsiung 80424, Taiwan, ROC (China); Tsai, Jenn-Kai [Department of Electronics Engineering, National Formosa University, Hu-Wei, Yun-Lin County 63208, Taiwan, ROC (China); Schuber, Ralf; Schaadt, Daniel [Institute of Applied Physics/DFG-Center for Functional Nanostructures (CFN), Karlsruhe Institute of Technology (KIT), Karlsruhe (Germany)

    2012-07-31

    We demonstrated a molecular beam epitaxy method to resolve the dilemma between structural and morphological quality in growth of the GaN epilayer. A gradient buffer layer was grown in such a way that the N/Ga ratio was gradually changed from nitrogen-rich to gallium-rich. The GaN epitaxial layer was then grown on the gradient buffer layer. In the X-ray diffraction analysis of GaN(002) rocking curves, we found that the full width at half-maximum was improved from 531.69 Double-Prime to 59.43 Double-Prime for the sample with a gradient buffer layer as compared to a purely gallium-rich grown sample. Atomic force microscopy analysis showed that the root-mean-square roughness of the surface was improved from 18.28 nm to 1.62 nm over an area of 5 Multiplication-Sign 5 {mu}m{sup 2} with respect to a purely nitrogen-rich grown sample. Raman scattering showed the presence of a slightly tilted plane in the gradient layer. Furthermore we showed that the gradient layer can also slash the strain force caused by either Ga-rich GaN epitaxial layer or AlN buffer layer. - Highlights: Black-Right-Pointing-Pointer The samples were grown by plasma-assisted molecular beam epitaxy. Black-Right-Pointing-Pointer The GaN epilayer was grown on sapphire substrate. Black-Right-Pointing-Pointer The samples were characterized by X-ray diffraction and atomic force microscopy. Black-Right-Pointing-Pointer The sample quality was improved by gradient buffer layer.

  11. Study on method to simulate light propagation on tissue with characteristics of radial-beam LED based on Monte-Carlo method.

    Science.gov (United States)

    Song, Sangha; Elgezua, Inko; Kobayashi, Yo; Fujie, Masakatsu G

    2013-01-01

    In biomedical, Monte-carlo simulation is commonly used for simulation of light diffusion in tissue. But, most of previous studies did not consider a radial beam LED as light source. Therefore, we considered characteristics of a radial beam LED and applied them on MC simulation as light source. In this paper, we consider 3 characteristics of radial beam LED. The first is an initial launch area of photons. The second is an incident angle of a photon at an initial photon launching area. The third is the refraction effect according to contact area between LED and a turbid medium. For the verification of the MC simulation, we compared simulation and experimental results. The average of the correlation coefficient between simulation and experimental results is 0.9954. Through this study, we show an effective method to simulate light diffusion on tissue with characteristics for radial beam LED based on MC simulation.

  12. A comparison of two sleep spindle detection methods based on all night averages: individually adjusted versus fixed frequencies

    Directory of Open Access Journals (Sweden)

    Péter Przemyslaw Ujma

    2015-02-01

    Full Text Available Sleep spindles are frequently studied for their relationship with state and trait cognitive variables, and they are thought to play an important role in sleep-related memory consolidation. Due to their frequent occurrence in NREM sleep, the detection of sleep spindles is only feasible using automatic algorithms, of which a large number is available. We compared subject averages of the spindle parameters computed by a fixed frequency (11-13 Hz for slow spindles, 13-15 Hz for fast spindles automatic detection algorithm and the individual adjustment method (IAM, which uses individual frequency bands for sleep spindle detection. Fast spindle duration and amplitude are strongly correlated in the two algorithms, but there is little overlap in fast spindle density and slow spindle parameters in general. The agreement between fixed and manually determined sleep spindle frequencies is limited, especially in case of slow spindles. This is the most likely reason for the poor agreement between the two detection methods in case of slow spindle parameters. Our results suggest that while various algorithms may reliably detect fast spindles, a more sophisticated algorithm primed to individual spindle frequencies is necessary for the detection of slow spindles as well as individual variations in the number of spindles in general.

  13. A spectrum-compatible earthquake simulation method with simultaneous adjustment to a typical earthquake energy time distribution

    International Nuclear Information System (INIS)

    Alvarez, L.M.

    1993-01-01

    There are several aspects of the structural dynamic design, such as soil structure interaction phenomena, seismic qualification of structural and mechanic components and non-linear dynamic behaviour of special components under a strong seismic excitation, which are advantageously analyzed in the Time Domain. A proper application of this method requires an extensive and comprehensive data base of real and/or simulated earthquake records, conveniently scaled to satisfy the Target Response Spectrum. Most of the present methods for synthetic earthquake records generation are only limited to adjust the ordinates of a Target Response Spectrum in a statistical way and do not take into account the time distribution of the energy content of real earthquakes. This paper proposes a method for the generation of artificial earthquake records based on a linear combination of a set of damped sinusoidal waves, whose control variables are amplitude, frequency and time shifting from the beginning of each individual wave to the record origin. By means of a very simple algorithm, based on the superposition of the time distribution of the energy content in every single wave, a simultaneous fitting of a Target Response Spectrum and of a statistical time distribution of earthquake energy has been achieved. The time energy distribution has been evaluated, statistically, by means of the average time distribution of the well-known Arias Intensity Integral on a set of more than one hundred different real earthquake records. The proposed method ensures a more realistic definition of the influence of a simulated earthquake upon a real structure because it can generate acceleration records with stationary or non-stationary frequency contents. It can also provide a real time distribution to the earthquake total energy content, which can be advantageously used for the analysis of the development of structural ductility, that -in turn- is closely related to earthquakes' time energy distribution

  14. Justification and implementation of the coordinate method among potentially possible precise methods for measuring angles between axes of small-angle beams

    Science.gov (United States)

    Kudryavtsev, M. D.

    2017-08-01

    A series of studies devoted to the theoretical justification and development of methods and tools for angular measurements based on the use of multiple sources of optical beams with a small angular aperture is continued. The source used in this study is a holographic prism: a fluorite single crystal with a system of superimposed holograms recorded in its bulk, which generates a series of diffracted small-angle beams in the form of a flat fan under illumination by a reference laser. This fan has a high spatial stability, including constancy of angles between any pair of fan beams in a wide range of external conditions. Based on the previously introduced notion of an effective beam axis, potential exact methods for measuring angles between fan beams are considered, and a coordinate method using a coordinate measuring machine and a CCD recorder is substantiated and implemented. The accuracy of the proposed method is analyzed. It is shown that its errors can potentially be reduced to a level of 1″ or even less.

  15. SU-E-T-446: Group-Sparsity Based Angle Generation Method for Beam Angle Optimization

    International Nuclear Information System (INIS)

    Gao, H

    2015-01-01

    Purpose: This work is to develop the effective algorithm for beam angle optimization (BAO), with the emphasis on enabling further improvement from existing treatment-dependent templates based on clinical knowledge and experience. Methods: The proposed BAO algorithm utilizes a priori beam angle templates as the initial guess, and iteratively generates angular updates for this initial set, namely angle generation method, with improved dose conformality that is quantitatively measured by the objective function. That is, during each iteration, we select “the test angle” in the initial set, and use group-sparsity based fluence map optimization to identify “the candidate angle” for updating “the test angle”, for which all the angles in the initial set except “the test angle”, namely “the fixed set”, are set free, i.e., with no group-sparsity penalty, and the rest of angles including “the test angle” during this iteration are in “the working set”. And then “the candidate angle” is selected with the smallest objective function value from the angles in “the working set” with locally maximal group sparsity, and replaces “the test angle” if “the fixed set” with “the candidate angle” has a smaller objective function value by solving the standard fluence map optimization (with no group-sparsity regularization). Similarly other angles in the initial set are in turn selected as “the test angle” for angular updates and this chain of updates is iterated until no further new angular update is identified for a full loop. Results: The tests using the MGH public prostate dataset demonstrated the effectiveness of the proposed BAO algorithm. For example, the optimized angular set from the proposed BAO algorithm was better the MGH template. Conclusion: A new BAO algorithm is proposed based on the angle generation method via group sparsity, with improved dose conformality from the given template. Hao Gao was partially supported by the

  16. Comparison of LHC Beam Loss Maps Using the Transverse Damper Blow Up and Tune Resonance Crossing Methods

    CERN Document Server

    Moens, V; Redaelli, S; Salvachua, B; Valentino, G

    2013-01-01

    The LHC collimator settings are qualified regularly via beam loss maps. In this procedure, the beam is artificially excited to create abnormal loss rates. The transverse damper blow up (ADT) and tune resonance crossing methods (QT) are used to increase the betatron amplitude of particles and verify the efficiency of the collimation cleaning hierarchy in IR7. This paper presents a quantitative comparison of the methods, for the qualification of the collimator settings at different operating points in the LHC machine cycle. The analysis is done using Beam Loss Monitor (BLM) with integration times of 1.3 s and 80 ms, the latter being available as from the 2012 run onwards. We present here the use of the faster BLM data (80 ms) to study the time evolution of the losses in IR3 and IR7 during offmomentum loss maps.

  17. Methods and approaches to provide feedback from nuclear and covariance data adjustment for improvement of nuclear data files. SG39 meeting, December 2016

    International Nuclear Information System (INIS)

    Cabellos, Oscar; ); PELLONI, Sandro; Ivanov, Evgeny; Sobes, Vladimir; Fukushima, M.; Yokoyama, Kenji; Palmiotti, Giuseppe; Kodeli, Ivo

    2016-12-01

    The aim of WPEC subgroup 39 'Methods and approaches to provide feedback from nuclear and covariance data adjustment for improvement of nuclear data files' is to provide criteria and practical approaches to use effectively the results of sensitivity analyses and cross section adjustments for feedback to evaluators and differential measurement experimentalists in order to improve the knowledge of neutron cross sections, uncertainties, and correlations to be used in a wide range of applications. This document is the proceedings of the eighth Subgroup 39 meeting, held at the OECD NEA, Boulogne-Billancourt, France, on 1-2 December 2016. It comprises all the available presentations (slides) given by the participants: A - Presentations: Welcome and actions review (Oscar CABELLOS); B - Methods: - Detailed comparison of Progressive Incremental Adjustment (PIA) sequence results involving adjustments of spectral indices and coolant density effects on the basis of the SG33 benchmark (Sandro PELLONI); - ND assessment alternatives: Validation matrix vs XS adjustment (Evgeny IVANOV); - Implementation of Resonance Parameter Sensitivity Coefficients Calculation in CE TSUNAMI-3D (Vladimir SOBES); C - Experiment analysis, sensitivity calculations and benchmarks: - Benchmark tests of ENDF/B-VIII.0 beta 1 using sodium void reactivity worth of FCA-XXVII-1 assembly (M. FUKUSHIMA, Kenji YOKOYAMA); D - Adjustments: - Cross-section adjustment based on JENDL-4.0 using new experiments on the basis of the SG33 benchmark (Kenji YOKOYAMA); - Comparison of adjustment trends with the Cielo evaluation (Sandro PELLONI); - Expanded adjustment in support of CIELO initiative (Giuseppe PALMIOTTI); - First preliminary results of the adjustment exercise using ASPIS Fe88 and SNEAK-7A/7B k eff and b eff benchmarks (Ivo KODELI); E - Future actions, deliverables: - Discussion on future of SG39 and possible new subgroup (Giuseppe PALMIOTTI); - WPEC sub-group proposal: Investigation of Covariance Data

  18. Device and method for generating a beam of acoustic energy from a borehole, and applications thereof

    Science.gov (United States)

    Vu, Cung Khac; Sinha, Dipen N; Pantea, Cristian; Nihei, Kurt T; Schmitt, Denis P; Skelt, Christopher

    2013-10-01

    In some aspects of the invention, a method of generating a beam of acoustic energy in a borehole is disclosed. The method includes generating a first broad-band acoustic pulse at a first broad-band frequency range having a first central frequency and a first bandwidth spread; generating a second broad-band acoustic pulse at a second broad-band frequency range different than the first frequency range having a second central frequency and a second bandwidth spread, wherein the first acoustic pulse and second acoustic pulse are generated by at least one transducer arranged on a tool located within the borehole; and transmitting the first and the second broad-band acoustic pulses into an acoustically non-linear medium, wherein the composition of the non-linear medium produces a collimated pulse by a non-linear mixing of the first and second acoustic pulses, wherein the collimated pulse has a frequency equal to the difference in frequencies between the first central frequency and the second central frequency and a bandwidth spread equal to the sum of the first bandwidth spread and the second bandwidth spread.

  19. Methods for calculating energy and current requirements for industrial electron beam processing

    International Nuclear Information System (INIS)

    Cleland, M.R.; Farrell, J.P.

    1976-01-01

    The practical problems of determining electron beam parameters for industrial irradiation processes are discussed. To assist the radiation engineer in this task, the physical aspects of electron beam absorption are briefly described. Formulas are derived for calculating the surface dose in the treated material using the electron energy, beam current and the area thruput rate of the conveyor. For thick absorbers electron transport results are used to obtain the depth-dose distributions. From these the average dose in the material, anti D, and the beam power utilization efficiency, F/sub p/, can be found by integration over the distributions. These concepts can be used to relate the electron beam power to the mass thruput rate. Qualitatively, the thickness of the material determines the beam energy, the area thruput rate and surface dose determine the beam current while the mass thruput rate and average depth-dose determine the beam power requirements. Graphs are presented showing these relationships as a function of electron energy from 0.2 to 4.0 MeV for polystyrene. With this information, the determination of electron energy and current requirements is a relatively simple procedure

  20. The parameters effect on the structural performance of damaged steel box beam using Taguchi method

    Science.gov (United States)

    El-taly, Boshra A.; Abd El Hameed, Mohamed F.

    2018-01-01

    In the current study, the influence of notch or opening parameters and the positions of the applied load on the structural performance of steel box beams up to failure was investigated using Finite Element analysis program, ANSYS. The Taguchi-based design of experiments technique was used to plan the current study. The plan included 12 box steel beams; three intact beams, and nine damaged beams (with opening) in the beams web. The numerical studies were conducted under varying the spacing between the two concentrated point loads (location of applied loads), the notch (opening) position, and the ratio between depth and width of the notch with a constant notch area. According to Taguchi analysis, factor X (location of the applied loads) was found the highest contributing parameters for the variation of the ultimate load, vertical deformation, shear stresses, and the compressive normal stresses.

  1. Physical principles of the surface plasma method for producing beams of negative ions

    International Nuclear Information System (INIS)

    Bel'chenko, Yu.I.; Dimov, G.I.; Dudnikov, V.G.

    1977-01-01

    The processes which are important for the production of intense beams of negative ions from surface plasma sources (SPS) are examined. The formation of negative ions when atomic particles interact with a surface is analyzed on the basis of both experimental results obtained when a surface was bombarded with beams and recently developed theoretical considerations of reflection, scattering, and electron exchange. The characteristic features of these processes in SPS, when a surface is bombarded with intense fluxes of plasma particles, are revealed in special experiments. The characteristics of generation and acceleration of the bombarding particles in a gas discharge SPS plasma, the characteristics of transportation of negative ions through the plasma toward the beam forming system, the role of cesium in SPS, and the characteristics of formation of the intense negative ion beams as well as the removal of parasite electrons from the beam

  2. A method for robust segmentation of arbitrarily shaped radiopaque structures in cone-beam CT projections.

    Science.gov (United States)

    Poulsen, Per Rugaard; Fledelius, Walther; Keall, Paul J; Weiss, Elisabeth; Lu, Jun; Brackbill, Emily; Hugo, Geoffrey D

    2011-04-01

    Implanted markers are commonly used in radiotherapy for x-ray based target localization. The projected marker position in a series of cone-beam CT (CBCT) projections can be used to estimate the three dimensional (3D) target trajectory during the CBCT acquisition. This has important applications in tumor motion management such as motion inclusive, gating, and tumor tracking strategies. However, for irregularly shaped markers, reliable segmentation is challenged by large variations in the marker shape with projection angle. The purpose of this study was to develop a semiautomated method for robust and reliable segmentation of arbitrarily shaped radiopaque markers in CBCT projections. The segmentation method involved the following three steps: (1) Threshold based segmentation of the marker in three to six selected projections with large angular separation, good marker contrast, and uniform background; (2) construction of a 3D marker model by coalignment and backprojection of the threshold-based segmentations; and (3) construction of marker templates at all imaging angles by projection of the 3D model and use of these templates for template-based segmentation. The versatility of the segmentation method was demonstrated by segmentation of the following structures in the projections from two clinical CBCT scans: (1) Three linear fiducial markers (Visicoil) implanted in or near a lung tumor and (2) an artificial cardiac valve in a lung cancer patient. Automatic marker segmentation was obtained in more than 99.9% of the cases. The segmentation failed in a few cases where the marker was either close to a structure of similar appearance or hidden behind a dense structure (data cable). A robust template-based method for segmentation of arbitrarily shaped radiopaque markers in CBCT projections was developed.

  3. Method of determining characteristics of a high-energy neutral beam and facility for performing the method

    International Nuclear Information System (INIS)

    Fink, J.H.

    1979-01-01

    The ion beam consisting of H, D, T and He serves to supply energy to a plasma. For monitoring the beam and certain characteristics it is passed through a neutralizing chamber containing a neutralizing gas, and the current, generated in circuits by ions drifting to the wall, is measured. For this purpose the chamber is subdivided into longitudinal or transversal segments being electrically insulated from each other. Each segment is part of a separate current-measuring device, the direction of propagation of the ion beam thus being also susceptible to measurement. (DG) [de

  4. Methods to adjust for misclassification in the quantiles for the generalized linear model with measurement error in continuous exposures.

    Science.gov (United States)

    Wang, Ching-Yun; Tapsoba, Jean De Dieu; Duggan, Catherine; Campbell, Kristin L; McTiernan, Anne

    2016-05-10

    In many biomedical studies, covariates of interest may be measured with errors. However, frequently in a regression analysis, the quantiles of the exposure variable are often used as the covariates in the regression analysis. Because of measurement errors in the continuous exposure variable, there could be misclassification in the quantiles for the exposure variable. Misclassification in the quantiles could lead to bias estimation in the association between the exposure variable and the outcome variable. Adjustment for misclassification will be challenging when the gold standard variables are not available. In this paper, we develop two regression calibration estimators to reduce bias in effect estimation. The first estimator is normal likelihood-based. The second estimator is linearization-based, and it provides a simple and practical correction. Finite sample performance is examined via a simulation study. We apply the methods to a four-arm randomized clinical trial that tested exercise and weight loss interventions in women aged 50-75 years. Copyright © 2015 John Wiley & Sons, Ltd.

  5. A single-beam titration method for the quantification of open-path Fourier transform infrared spectroscopy

    International Nuclear Information System (INIS)

    Sung, Lung-Yu; Lu, Chia-Jung

    2014-01-01

    This study introduced a quantitative method that can be used to measure the concentration of analytes directly from a single-beam spectrum of open-path Fourier Transform Infrared Spectroscopy (OP-FTIR). The peak shapes of the analytes in a single-beam spectrum were gradually canceled (i.e., “titrated”) by dividing an aliquot of a standard transmittance spectrum with a known concentration, and the sum of the squared differential synthetic spectrum was calculated as an indicator for the end point of this titration. The quantity of a standard transmittance spectrum that is needed to reach the end point can be used to calculate the concentrations of the analytes. A NIST traceable gas standard containing six known compounds was used to compare the quantitative accuracy of both this titration method and that of a classic least square (CLS) using a closed-cell FTIR spectrum. The continuous FTIR analysis of industrial exhausting stack showed that concentration trends were consistent between the CLS and titration methods. The titration method allowed the quantification to be performed without the need of a clean single-beam background spectrum, which was beneficial for the field measurement of OP-FTIR. Persistent constituents of the atmosphere, such as NH 3 , CH 4 and CO, were successfully quantified using the single-beam titration method with OP-FTIR data that is normally inaccurate when using the CLS method due to the lack of a suitable background spectrum. Also, the synthetic spectrum at the titration end point contained virtually no peaks of analytes, but it did contain the remaining information needed to provide an alternative means of obtaining an ideal single-beam background for OP-FTIR. - Highlights: • Establish single beam titration quantification method for OP-FTIR. • Define the indicator for the end-point of spectrum titration. • An ideal background spectrum can be obtained using single beam titration. • Compare the quantification between titration

  6. Investigation of the HU-density conversion method and comparison of dose distribution for dose calculation on MV cone beam CT images

    International Nuclear Information System (INIS)

    Kim, Min Joo; Lee, Seu Ran; Suh, Tae Suk

    2011-01-01

    Modern radiation therapy techniques, such as Image-guided radiation therapy (IGRT), Adaptive radiation therapy (ART) has become a routine clinical practice on linear accelerators for the increase the tumor dose conformity and improvement of normal tissue sparing at the same time. For these highly developed techniques, megavoltage cone beam computed tomography (MVCBCT) system produce volumetric images at just one rotation of the x-ray beam source and detector on the bottom of conventional linear accelerator for real-time application of patient condition into treatment planning. MV CBCT image scan be directly registered to a reference CT data set which is usually kilo-voltage fan-beam computed tomography (kVFBCT) on treatment planning system and the registered image scan be used to adjust patient set-up error. However, to use MV CBCT images in radiotherapy, reliable electron density (ED) distribution are required. Patients scattering, beam hardening and softening effect caused by different energy application between kVCT, MV CBCT can cause cupping artifacts in MV CBCT images and distortion of Houns field Unit (HU) to ED conversion. The goal of this study, for reliable application of MV CBCT images into dose calculation, MV CBCT images was modified to correct distortion of HU to ED using the relationship of HU and ED from kV FBCT and MV CBCT images. The HU-density conversion was performed on MV CBCT image set using Dose difference map was showing in Figure 1. Finally, percentage differences above 3% were reduced depending on applying density calibration method. As a result, total error co uld be reduced to under 3%. The present study demonstrates that dose calculation accuracy using MV CBCT image set can be improved my applying HU-density conversion method. The dose calculation and comparison of dose distribution from MV CBCT image set with/without HU-density conversion method was performed. An advantage of this study compared to other approaches is that HU

  7. Investigation of the HU-density conversion method and comparison of dose distribution for dose calculation on MV cone beam CT images

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Min Joo; Lee, Seu Ran; Suh, Tae Suk [Dept. of Biomedical Engineering, The Catholic University of Korea, Bucheon (Korea, Republic of)

    2011-11-15

    Modern radiation therapy techniques, such as Image-guided radiation therapy (IGRT), Adaptive radiation therapy (ART) has become a routine clinical practice on linear accelerators for the increase the tumor dose conformity and improvement of normal tissue sparing at the same time. For these highly developed techniques, megavoltage cone beam computed tomography (MVCBCT) system produce volumetric images at just one rotation of the x-ray beam source and detector on the bottom of conventional linear accelerator for real-time application of patient condition into treatment planning. MV CBCT image scan be directly registered to a reference CT data set which is usually kilo-voltage fan-beam computed tomography (kVFBCT) on treatment planning system and the registered image scan be used to adjust patient set-up error. However, to use MV CBCT images in radiotherapy, reliable electron density (ED) distribution are required. Patients scattering, beam hardening and softening effect caused by different energy application between kVCT, MV CBCT can cause cupping artifacts in MV CBCT images and distortion of Houns field Unit (HU) to ED conversion. The goal of this study, for reliable application of MV CBCT images into dose calculation, MV CBCT images was modified to correct distortion of HU to ED using the relationship of HU and ED from kV FBCT and MV CBCT images. The HU-density conversion was performed on MV CBCT image set using Dose difference map was showing in Figure 1. Finally, percentage differences above 3% were reduced depending on applying density calibration method. As a result, total error co uld be reduced to under 3%. The present study demonstrates that dose calculation accuracy using MV CBCT image set can be improved my applying HU-density conversion method. The dose calculation and comparison of dose distribution from MV CBCT image set with/without HU-density conversion method was performed. An advantage of this study compared to other approaches is that HU

  8. Substrate bias effect on crystallinity of polycrystalline silicon thin films prepared by pulsed ion-beam evaporation method

    International Nuclear Information System (INIS)

    Ali, Fazlat; Gunji, Michiharu; Yang, Sung-Chae; Suzuki, Tsuneo; Suematsu, Hisayuki; Jiang, Weihua; Yatsui, Kiyoshi

    2002-01-01

    The deposition of polycrystalline silicon thin films has been tried by a pulsed ion-beam evaporation method, where high crystallinity and deposition rate have been achieved without heating the substrate. The crystallinity and the deposition rate were improved by applying bias voltage to the substrate, where instantaneous substrate heating might have occurred by ion-bombardment. (author)

  9. High resolution acoustic measurement system and beam pattern reconstruction method for bat echolocation emissions.

    Science.gov (United States)

    Gaudette, Jason E; Kloepper, Laura N; Warnecke, Michaela; Simmons, James A

    2014-01-01

    Measurements of the transmit beam patterns emitted by echolocating bats have previously been limited to cross-sectional planes or averaged over multiple signals using sparse microphone arrays. To date, no high-resolution measurements of individual bat transmit beams have been reported in the literature. Recent studies indicate that bats may change the time-frequency structure of their calls depending on the task, and suggest that their beam patterns are more dynamic than previously thought. To investigate beam pattern dynamics in a variety of bat species, a high-density reconfigurable microphone array was designed and constructed using low-cost ultrasonic microphones and custom electronic circuitry. The planar array is 1.83 m wide by 1.42 m tall with microphones positioned on a 2.54 cm square grid. The system can capture up to 228 channels simultaneously at a 500 kHz sampling rate. Beam patterns are reconstructed in azimuth, elevation, and frequency for visualization and further analysis. Validation of the array measurement system and post-processing functions is shown by reconstructing the beam pattern of a transducer with a fixed circular aperture and comparing the result with a theoretical model. To demonstrate the system in use, transmit beam patterns of the big brown bat, Eptesicus fuscus, are shown.

  10. Evaluation of a simple method for chopping Penning surface-plasma source H- beams

    International Nuclear Information System (INIS)

    Smith, H.V. Jr.; Allison, P.; Schneider, J.D.; Stelzer, J.E.; Stevens, R.R. Jr.

    1995-01-01

    Accumulator rings proposed for use in high-intensity spallation-neutron sources require a chopped beam with ∼100-ns-wide particle-free gaps at 1--2 MHz rates, with fall and rise times ≤20 ns. Chopping the beam directly in the ion source may be an attractive way to provide the desired beam structure. Previous measurements showed that placing a grounded collar in the drift region just before the emission aperture lowers the e - /H - ratio in the Penning surface-plasma source H - beam. We electrically isolated the collar and biased it to modulate the extracted H - current. Positive collar bias decreases the H - beam by up to 90%. The fastest H - current fall and rise times achieved to date are 400 ns and 2 μs, respectively. The current fall time is close to the 300-ns pulser rise time. The current rise time is considerably longer than the 500-ns pulser fall time. Negative collar bias lowers the H - beam by up to 50%. Simulations indicate that the beam time structure will be preserved in transport from the ion source to the radio-frequency quadrupole entrance

  11. Simulation of therapeutic electron beam tracking through a non-uniform magnetic field using finite element method.

    Science.gov (United States)

    Tahmasebibirgani, Mohammad Javad; Maskani, Reza; Behrooz, Mohammad Ali; Zabihzadeh, Mansour; Shahbazian, Hojatollah; Fatahiasl, Jafar; Chegeni, Nahid

    2017-04-01

    In radiotherapy, megaelectron volt (MeV) electrons are employed for treatment of superficial cancers. Magnetic fields can be used for deflection and deformation of the electron flow. A magnetic field is composed of non-uniform permanent magnets. The primary electrons are not mono-energetic and completely parallel. Calculation of electron beam deflection requires using complex mathematical methods. In this study, a device was made to apply a magnetic field to an electron beam and the path of electrons was simulated in the magnetic field using finite element method. A mini-applicator equipped with two neodymium permanent magnets was designed that enables tuning the distance between magnets. This device was placed in a standard applicator of Varian 2100 CD linear accelerator. The mini-applicator was simulated in CST Studio finite element software. Deflection angle and displacement of the electron beam was calculated after passing through the magnetic field. By determining a 2 to 5cm distance between two poles, various intensities of transverse magnetic field was created. The accelerator head was turned so that the deflected electrons became vertical to the water surface. To measure the displacement of the electron beam, EBT2 GafChromic films were employed. After being exposed, the films were scanned using HP G3010 reflection scanner and their optical density was extracted using programming in MATLAB environment. Displacement of the electron beam was compared with results of simulation after applying the magnetic field. Simulation results of the magnetic field showed good agreement with measured values. Maximum deflection angle for a 12 MeV beam was 32.9° and minimum deflection for 15 MeV was 12.1°. Measurement with the film showed precision of simulation in predicting the amount of displacement in the electron beam. A magnetic mini-applicator was made and simulated using finite element method. Deflection angle and displacement of electron beam were calculated. With

  12. Corrections in the gold foil activation method for determination of neutron beam density

    DEFF Research Database (Denmark)

    Als-Nielsen, Jens Aage

    1967-01-01

    A finite foil thickness and deviation in the cross section from the 1ν law imply corrections in the determination of neutron beam densities by means of foil activation. These corrections, which depend on the neutron velocity distribution, have been examined in general and are given in a specific...... example for a reactor beam transmitted through a 30 cm Bi filter. The effective cross section differs 0.5% from the capture cross section at 2200 m/s. For a 20 mg/cm2 Au foil the correction for beam attenuation and hardening through the foil is 0.7% and the activity correction is 1.5%....

  13. Comparison of infrared laser beam shaping by diffractive and refractive methods

    CSIR Research Space (South Africa)

    Forbes, A

    2005-08-01

    Full Text Available . These potential errors are simulated for the DOE. 3.2.1 Input beam profile dependence To model the impact of this potential problem on the performance of the DOE, a “mixed” beam was introduced, consisting of a combination of TEM01, and a “donut” mode made from... a combination of TEM10 and TEM00 modes. The mix was created using 1 part of the donut mode (combination of the TEM01 and TEM10), with n parts (referred to as the mixture value) of the TEM00 mode. This beam was propagated through the DOE...

  14. Fabrication of Si surface pattern by Ar beam irradiation and annealing method

    International Nuclear Information System (INIS)

    Zhang, J.; Momota, S.; Maeda, K.; Terauchi, H.; Furuta, M.; Kawaharamura, T.; Nitta, N.; Wang, D.

    2012-01-01

    The fabrication process of crater structures on Si crystal has been studied by an irradiation of Ar beam and a thermal annealing at 600 °C. The fabricated surface was measured by field emission scanning electron microscope and atomic force microscope. The results have shown the controllability of specifications of crater formation such as density, diameter and depth by changing two irradiation parameters, fluence and energy of Ar ions. By changing the fluence over a range of 1 ∼ 10 × 10 16 /cm 2 , we could control a density of crater 0 ∼ 39 counts/100μm 2 . By changing the energy over a range of 90 ∼ 270 keV, we could control a diameter and a depth of crater in 0.8 ∼ 4.1μm and 99 ∼ 229nm, respectively. The present result is consistent with the previously proposed model that the crater structure would be arising from an exfoliated surface layer of silicon. The present result has indicated the possibility of the crater production phenomena as a hopeful method to fabricate the surface pattern on a micro-nano meter scale.

  15. A fast 4D cone beam CT reconstruction method based on the OSC-TV algorithm.

    Science.gov (United States)

    Mascolo-Fortin, Julia; Matenine, Dmitri; Archambault, Louis; Després, Philippe

    2018-01-01

    Four-dimensional cone beam computed tomography allows for temporally resolved imaging with useful applications in radiotherapy, but raises particular challenges in terms of image quality and computation time. The purpose of this work is to develop a fast and accurate 4D algorithm by adapting a GPU-accelerated ordered subsets convex algorithm (OSC), combined with the total variation minimization regularization technique (TV). Different initialization schemes were studied to adapt the OSC-TV algorithm to 4D reconstruction: each respiratory phase was initialized either with a 3D reconstruction or a blank image. Reconstruction algorithms were tested on a dynamic numerical phantom and on a clinical dataset. 4D iterations were implemented for a cluster of 8 GPUs. All developed methods allowed for an adequate visualization of the respiratory movement and compared favorably to the McKinnon-Bates and adaptive steepest descent projection onto convex sets algorithms, while the 4D reconstructions initialized from a prior 3D reconstruction led to better overall image quality. The most suitable adaptation of OSC-TV to 4D CBCT was found to be a combination of a prior FDK reconstruction and a 4D OSC-TV reconstruction with a reconstruction time of 4.5 minutes. This relatively short reconstruction time could facilitate a clinical use.

  16. Electron Energy Resolution of the ATLAS TILECAL Modules with Flat Filter Method (July 2002 test beam)

    CERN Document Server

    Kulchitskii, Yu A; Vinogradov, V B

    2005-01-01

    The constructed ATLAS detector at the LHC will have the great physics discovery potential, in particular in the detection of a heavy Higgs boson. Calorimeters will play a crucial role in it. It is necessary to have confidence that the calorimeters will perform as expected. With the aim of understanding of performance of the ATLAS Tile hadronic calorimeter to electrons 12\\% of modules have been exposed in electron beams with various energies by three possible ways: cell-scan at $\\theta =20^o$ at the centers of the front face cells, $\\eta$-scan and tilerow scan at $\\theta = 90^o$ for the module side cells. We have extracted the electron energy resolutions of the $EBM-$ (ANL-44), $EBM+$ (IFA-42) and $BM$ (JINR-55) Modules of the ATLAS Tile Calorimeter at energies E = 10, 20, 50, 100 and 180 GeV and $\\theta = 20^o$ and $90^o $ and $\\eta$ scan from the July 2002 testbeam run data using the flat filter method of the PMT signal reconstruction. We have determined the statistical and constant terms for the electron en...

  17. Electron Energy Resolution of the ATLAS TILECAL Modules with Fit Filter Method (July 2002 test beam)

    CERN Document Server

    Kulchitskii, Yu A; Vinogradov, V B

    2006-01-01

    The constructed ATLAS detector at the LHC will have the great physics discovery potential, in particular in the detection of a heavy Higgs boson. Calorimeters will play a crucial role in it. It is necessary to have confidence that the calorimeters will perform as expected. With the aim of understanding of performance of the ATLAS Tile hadronic calorimeter to electrons 12\\% of modules have been exposed in electron beams with various energies by three possible ways: cell-scan at $\\theta =20^o$ at the centers of the front face cells, $\\eta$-scan and tilerow scan at $\\theta = 90^o$ for the module side cells. We have extracted the electron energy resolutions of the $EBM-$ (ANL-44), $EBM+$ (IFA-42) and $BM$ (JINR-55) Modules of the ATLAS Tile Calorimeter at energies E = 10, 20, 50, 100 and 180 GeV and $\\theta = 20^o$ and $90^o $ and $\\eta$ scan from the July 2002 testbeam run data using the fit filter method of the PMT signal reconstruction. We have determined the statistical and constant terms for the electron ene...

  18. Disinfection of sewage sludge by gamma radiation, electron beams and alternative methods

    International Nuclear Information System (INIS)

    Lessel, T.

    1997-01-01

    Sewage sludges generally contain high concentrations of pathogens, even after digestion or other conventional treatments for stabilization. Disinfection can be effected by irradiation (e.g. gamma or electron beam), by heat treatment (pasteurization or thermophilic stabilization), and by changing the pH (lime treatment). Irradiation is a simple and reliable process for disinfection with special advantages and favorable side-effects. Irradiation can be combined with oxygenation, heat or other treatments, with favorable synergistic effects. The total costs for the irradiation treatment of sewage sludges are comparable to those of alternative disinfection methods. Most of the worldwide practical experience has been obtained at the sewage-sludge irradiation plant in Geiselbullach (10 km west of Munich, Germany), which was continuously in operation from 1973 to 1993. A multidisciplinary research programme was conducted during the first 8 years. In subsequent years, the plant was operated commercially for sewage-sludge disinfection, without public funds. Other demonstration or research plants for sewage-sludge irradiation have been reported in the USA, India, Russia, Japan, Austria, Germany and Hungary. (author)

  19. DEVICE FOR MEASURING OF THERMAL LENS PARAMETERS IN LASER ACTIVE ELEMENTS WITH A PROBE BEAM METHOD

    Directory of Open Access Journals (Sweden)

    A. N. Zakharova

    2015-01-01

    Full Text Available We have developed a device for measuring of parameters of thermal lens (TL in laser active elements under longitudinal diode pumping. The measurements are based on the probe beam method. This device allows one to determine sign and optical power of the lens in the principal meridional planes, its sensitivity factor with respect to the absorbed pump power and astigmatism degree, fractional heat loading which make it possible to estimate integral impact of the photoelastic effect to the formation of TL in the laser element. The measurements are performed in a linearly polarized light at the wavelength of 532 nm. Pumping of the laser element is performed at 960 nm that makes it possible to study laser materials doped with Yb3+ and (Er3+, Yb3+ ions. The precision of measurements: for sensitivity factor of TL – 0,1 m-1/W, for astigmatism degree – 0,2 m-1/W, for fractional heat loading – 5 %, for the impact of the photoelastic effect – 0,5 × 10-6 K-1. This device is used for characterization of thermal lens in the laser active element from an yttrium vanadate crystal, Er3+,Yb3+:YVO .

  20. Comparison of surface detection methods to evaluate cone beam computed tomography data for three dimensional metrology

    International Nuclear Information System (INIS)

    Heinzl, Ch.; Kastner, J.; Georgi, B.; Lettenbauer, H.

    2007-01-01

    X-ray computed tomography (CT) is a well established method for non-destructive testing. In recent years the application of CT for three dimensional measurements and variance comparison became more and more important, since CT can measure both outer and inner geometries within a rather short time. Because of the much higher measurement speed and thus lower costs especially cone beam CT is an important issue of research in the field of dimensional metrology. One of the biggest challenges for the application of CT for metrology is the accurate detection of the surface between material and air or the interface between two different materials. By using a test-body various algorithms and data evaluation methods are compared and discussed within this paper. The investigated methods are: 1. Common methods: Otsu global threshold and an empirically determined best iso-surface. 2. Pipeline model: The pipeline model uses common 3D image processing filters and consists of three major steps: a.) an edge preserving diffusion filter to reduce noise without blurring the edges of the specimen. b.) A watershed segmentation filter is applied to the gradient image of the dataset to extract a fully connected binary volume. c.) The object surface is constructed using elastic surface nets. 3. Calypso R : Evaluation of inspection features by introduction of additional geometry information. The geometrical value is directly derived from the volume data without extracting a surface model, supposing a predefined geometry of a feature. For this purpose the commercial software Calypso R was used. By defining a geometrical feature e.g. a diameter or a distance optimised algorithms evaluate the CT - volume data to get the geometrical feature without a transformation to surface data. Common methods usually lead to no satisfactory results. The achieved accuracy is rather low, if the material thickness in the sample changes. The pipeline model and CT- Calypso R lead to much better results. Using

  1. Study of Thermo-Mechanical Effects Induced in Solids by High Energy Particle Beams: Analytical and Numerical Methods

    CERN Document Server

    Dallocchio, Alessandro; Kurtyka, T; Bertarelli, A

    2008-01-01

    Requirements of modern nuclear physics entail big efforts in the field of particle accelerator technology in order to build powerful machines providing particle beams at higher and higher energies; in this context, the Large Hadron Collider represents the future for particle physics. The LHC stores 360 MJ for each circulating beam; this large amount of energy is potentially destructive for accelerator equipments having direct interaction with particles; the need to handle high thermal loads bestows strategic importance to the study of thermo-mechanical problems in accelerator devices. The aim of this work is the study of thermo-mechanical effects induced in solids by high energy particle beams. Development of facilities devoted to the experimental test of accelerator equipments in real working conditions presents several technical difficulties and high cost; the importance of developing reliable methods and accurate models that could be efficiently applied during the design phase of the most critical particle...

  2. Semi-empirical equivalent field method for dose determination in midline block fields for cobalt - 60 beam

    International Nuclear Information System (INIS)

    Tagoe, S.N.A.; Nani, E.K.; Yarney, J.; Edusa, C.; Quayson-Sackey, K.; Nyamadi, K.M.; Sasu, E.

    2012-01-01

    For teletherapy treatment time calculations, midline block fields are resolved into two fields, but neglecting scattering from other fields, the effective equivalent square field size of the midline block is assumed to the resultant field. Such approach is underestimation, and may be detrimental in achieving the recommended uncertainty of ± 5 % for patient's radiation dose delivery. By comparison, the deviations of effective equivalent square field sizes by calculations and experiments were within 13.2 % for cobalt 60 beams of GWGP80 cobalt 60 teletherapy. Therefore, a modified method incorporating the scatter contributions was adopted to estimate the effective equivalent square field size for midline block field. The measured outputs of radiation beams with the block were compared with outputs of square fields without the blocks (only the block tray) at depths of 5 and 10 cm for the teletherapy machine employing isocentric technique, and the accuracy was within ± 3 % for the cobalt 60 beams. (au)

  3. APPLICATION OF FINITE ELEMENT METHOD TAKING INTO ACCOUNT PHYSICAL AND GEOMETRIC NONLINEARITY FOR THE CALCULATION OF PRESTRESSED REINFORCED CONCRETE BEAMS

    Directory of Open Access Journals (Sweden)

    Vladimir P. Agapov

    2017-01-01

    Full Text Available Abstract. Objectives Modern building codes prescribe the calculation of building structures taking into account the nonlinearity of deformation. To achieve this goal, the task is to develop a methodology for calculating prestressed reinforced concrete beams, taking into account physical and geometric nonlinearity. Methods The methodology is based on nonlinear calculation algorithms implemented and tested in the computation complex PRINS (a program for calculating engineering constructions for other types of construction. As a tool for solving this problem, the finite element method is used. Non-linear calculation of constructions is carried out by the PRINS computational complex using the stepwise iterative method. In this case, an equation is constructed and solved at the loading step, using modified Lagrangian coordinates. Results The basic formulas necessary for both the formation and the solution of a system of nonlinear algebraic equations by the stepwise iteration method are given, taking into account the loading, unloading and possible additional loading. A method for simulating prestressing is described by setting the temperature action on the reinforcement and stressing steel rod. Different approaches to accounting for physical and geometric nonlinearity of reinforced concrete beam rods are considered. A calculation example of a flat beam is given, in which the behaviour of the beam is analysed at various stages of its loading up to destruction. Conclusion A program is developed for the calculation of flat and spatially reinforced concrete beams taking into account the nonlinearity of deformation. The program is adapted to the computational complex PRINS and as part of this complex is available to a wide range of engineering, scientific and technical specialists. 

  4. Evaluation of ion chamber dependent correction factors for ionisation chamber dosimetry in proton beams using a Monte Carlo method

    International Nuclear Information System (INIS)

    Palmans, H.; Verhaegen, F.

    1995-01-01

    In the last decade, several clinical proton beam therapy facilities have been developed. To satisfy the demand for uniformity in clinical (routine) proton beam dosimetry two dosimetry protocols (ECHED and AAPM) have been published. Both protocols neglect the influence of ion chamber dependent parameters on dose determination in proton beams because of the scatter properties of these beams, although the problem has not been studied thoroughly yet. A comparison between water calorimetry and ionisation chamber dosimetry showed a discrepancy of 2.6% between the former method and ionometry following the ECHED protocol. Possibly, a small part of this difference can be attributed to chamber dependent correction factors. Indications for this possibility are found in ionometry measurements. To allow the simulation of complex geometries with different media necessary for the study of those corrections, an existing proton Monte Carlo code (PTRAN, Berger) has been modified. The original code, that applies Mollire's multiple scattering theory and Vavilov's energy straggling theory, calculates depth dose profiles, energy distributions and radial distributions for pencil beams in water. Comparisons with measurements and calculations reported in the literature are done to test the program's accuracy. Preliminary results of the influence of chamber design and chamber materials on dose to water determination are presented

  5. Evaluation of ion chamber dependent correction factors for ionisation chamber dosimetry in proton beams using a Monte Carlo method

    Energy Technology Data Exchange (ETDEWEB)

    Palmans, H. [Ghent Univ. (Belgium). Dept. of Biomedical Physics; Verhaegen, F.

    1995-12-01

    In the last decade, several clinical proton beam therapy facilities have been developed. To satisfy the demand for uniformity in clinical (routine) proton beam dosimetry two dosimetry protocols (ECHED and AAPM) have been published. Both protocols neglect the influence of ion chamber dependent parameters on dose determination in proton beams because of the scatter properties of these beams, although the problem has not been studied thoroughly yet. A comparison between water calorimetry and ionisation chamber dosimetry showed a discrepancy of 2.6% between the former method and ionometry following the ECHED protocol. Possibly, a small part of this difference can be attributed to chamber dependent correction factors. Indications for this possibility are found in ionometry measurements. To allow the simulation of complex geometries with different media necessary for the study of those corrections, an existing proton Monte Carlo code (PTRAN, Berger) has been modified. The original code, that applies Mollire`s multiple scattering theory and Vavilov`s energy straggling theory, calculates depth dose profiles, energy distributions and radial distributions for pencil beams in water. Comparisons with measurements and calculations reported in the literature are done to test the program`s accuracy. Preliminary results of the influence of chamber design and chamber materials on dose to water determination are presented.

  6. A new method to determine the projected coordinate origin of a cone-beam CT system using elliptical projection

    International Nuclear Information System (INIS)

    Yang Min; Li Baolei; Jin Xuling

    2010-01-01

    In order to determine the projected coordinate origin in the cone-beam CT scanning system with respect to the Feldkamp-Davis-Kress (FDK) algorithm,we propose a simple yet feasible method to accurately measure the projected coordinate origin. This method was established on the basis of the theory that the projection of a spherical object in the cone-beam field is an ellipse. We first utilized image processing and the least square estimation method to get each major axis of the elliptical Digital Radiography (DR) projections of a group of spherical objects. Then we determined the intersection point of the group of major axis by solving an over-determined equation set that was composed by the major axis equations of all the elliptical projections. Based on the experimental results,this new method was proved to be easy to implement in practical scanning systems with high accuracy and anti-noise capability. (authors)

  7. Evaluation of a method to shield a welding electron beam from magnetic interference

    Science.gov (United States)

    Wall, W. A.

    1976-01-01

    It is known that electron beams are easily deflected by magnetic and electrostatic fields. Therefore, to prevent weld defects, stray electromagnetic fields are avoided in electron beam welding chambers if at all possible. The successful results of tests conducted at MSFC to evaluate a simple magnetic shield made from steel tubing are reported. Tests indicate that this shield was up to 85 percent effective in reducing magnetic effects on the electron beam of a welding machine. In addition, residual magnetic fields within the shield were so nearly uniform that the net effect on the beam alignment was negligible. It is concluded that the shield, with the addition of a tungsten liner, could be used in production welding.

  8. Dynamics of infrared multiphonon dissociation of SF6 by molecular beam method

    International Nuclear Information System (INIS)

    Grant, E.R.; Coggiola, M.J.; Lee, Y.T.; Schulz, P.A.; Shen, Y.R.

    1977-01-01

    A crossed molecular beam apparatus has been adapted to study the dynamics of excitation and dissociation of polyatomic molecules in intense IR laser fields. Initial experiments have involved the study of the dissociation of SF 6 by CO 2 laser radiation at 10.6 μm. A molecular beam of SF 6 was formed by supersonic expansion using three stages of differential pumping. A grating tuned pulsed CO 2 TEA laser was used as the excitation source. The laser beam was focused by a 25 cm focal length ZnSe lens, and crossed the molecular beam near its focal point. The fragments produced by multiphonon dissociation of SF 6 within the small interaction region were detected as a function of recoil angle and velocity. (Auth.)

  9. The development of a curved beam element model applied to finite elements method

    International Nuclear Information System (INIS)

    Bento Filho, A.

    1980-01-01

    A procedure for the evaluation of the stiffness matrix for a thick curved beam element is developed, by means of the minimum potential energy principle, applied to finite elements. The displacement field is prescribed through polynomial expansions, and the interpolation model is determined by comparison of results obtained by the use of a sample of different expansions. As a limiting case of the curved beam, three cases of straight beams, with different dimensional ratios are analised, employing the approach proposed. Finally, an interpolation model is proposed and applied to a curved beam with great curvature. Desplacements and internal stresses are determined and the results are compared with those found in the literature. (Author) [pt

  10. Static and free vibration analysis of carbon nano wires based on Timoshenko beam theory using differential quadrature method

    Directory of Open Access Journals (Sweden)

    Maziar Janghorban

    Full Text Available Static and free vibration analysis of carbon nano wires with rectangular cross section based on Timoshenko beam theory is studied in this research. Differential quadrature method (DQM is employed to solve the governing equations. From the knowledge of author, it is the first time that free vibration of nano wires is investigated. It is also the first time that differential quadrature method is used for bending analysis of nano wires.

  11. Enhancement of image quality with a fast iterative scatter and beam hardening correction method for kV CBCT

    Energy Technology Data Exchange (ETDEWEB)

    Reitz, Irmtraud; Hesse, Bernd-Michael; Nill, Simeon; Tuecking, Thomas; Oelfke, Uwe [DKFZ, Heidelberg (Germany)

    2009-07-01

    The problem of the enormous amount of scattered radiation in kV CBCT (kilo voltage cone beam computer tomography) is addressed. Scatter causes undesirable streak- and cup-artifacts and results in a quantitative inaccuracy of reconstructed CT numbers, so that an accurate dose calculation might be impossible. Image contrast is also significantly reduced. Therefore we checked whether an appropriate implementation of the fast iterative scatter correction algorithm we have developed for MV (mega voltage) CBCT reduces the scatter contribution in a kV CBCT as well. This scatter correction method is based on a superposition of pre-calculated Monte Carlo generated pencil beam scatter kernels. The algorithm requires only a system calibration by measuring homogeneous slab phantoms with known water-equivalent thicknesses. In this study we compare scatter corrected CBCT images of several phantoms to the fan beam CT images acquired with a reduced cone angle (a slice-thickness of 14 mm in the isocenter) at the same system. Additional measurements at a different CBCT system were made (different energy spectrum and phantom-to-detector distance) and a first order approach of a fast beam hardening correction will be introduced. The observed, image quality of the scatter corrected CBCT images is comparable concerning resolution, noise and contrast-to-noise ratio to the images acquired in fan beam geometry. Compared to the CBCT without any corrections the contrast of the contrast-and-resolution phantom with scatter correction and additional beam hardening correction is improved by a factor of about 1.5. The reconstructed attenuation coefficients and the CT numbers of the scatter corrected CBCT images are close to the values of the images acquired in fan beam geometry for the most pronounced tissue types. Only for extreme dense tissue types like cortical bone we see a difference in CT numbers of 5.2%, which can be improved to 4.4% with the additional beam hardening correction. Cupping

  12. Methods and approaches to provide feedback from nuclear and covariance data adjustment for improvement of nuclear data files. SG39 meeting, November 2013

    International Nuclear Information System (INIS)

    De Saint Jean, C.; Dupont, E.; ); Dyrda, J.; Hursin, M.; Pelloni, S.; Ishikawa, M.; Ivanov, E.; Ivanova, T.; Kim, D.H.; Ee, Y.O.; Kodeli, I.; Leal, L.; Leichtle, D.; Palmiotti, G.; Salvatores, M.; Pronyaev, V.; Simakov, S.; )

    2013-11-01

    The aim of WPEC subgroup 39 'Methods and approaches to provide feedback from nuclear and covariance data adjustment for improvement of nuclear data files' is to provide criteria and practical approaches to use effectively the results of sensitivity analyses and cross section adjustments for feedback to evaluators and differential measurement experimentalists in order to improve the knowledge of neutron cross sections, uncertainties, and correlations to be used in a wide range of applications. This document is the proceedings of the first formal Subgroup 39 meeting held at the NEA, Issy-les-Moulineaux, France, on 28-29 November 2013. It comprises a Summary Record of the meeting and all the available presentations (slides) given by the participants: A - Recent data adjustments performances and trends: 1 - Recommendations from ADJ2010 adjustment (M. Ishikawa); 2 - Feedback on CIELO isotopes from ENDF/B-VII.0 adjustment (G. Palmiotti); 3 - Sensitivity and uncertainty results on FLATTOP-Pu (I. Kodeli); 4 - SG33 benchmark: Comparative adjustment results (S. Pelloni) 5 - Integral benchmarks for data assimilation: selection of a consistent set and establishment of integral correlations (E. Ivanov); 6 - PROTEUS experimental data (M. Hursin); 7 - Additional information on High Conversion Light Water Reactor (HCLWR aka FDWR-II) experiments (14 January 2014); 8 - Data assimilation of benchmark experiments for homogenous thermal/epithermal uranium systems (J. Dyrda); B - Methodology issues: 1 - Adjustment methodology issues (G. Palmiotti); 2 - Marginalisation, methodology issues and nuclear data parameter adjustment (C. De Saint Jean); 3 - Nuclear data parameter adjustment (G. Palmiotti). A list of issues and actions conclude the document

  13. A method to combine three dimensional dose distributions for external beam and brachytherapy radiation treatments for gynecological neoplasms

    International Nuclear Information System (INIS)

    Narayana, V.; Sahijdak, W.M.; Orton, C.G.

    1997-01-01

    Purpose: Radiation treatment of gynecological neoplasms, such as cervical carcinoma, usually combines external radiation therapy with one or more intracavitary brachytherapy applications. Although the dose from external beam radiation therapy and brachytherapy can be calculated and displayed in 3D individually, the dose distributions are not combined. At most, combined point doses are calculated for select points using various time-dose models. In this study, we present a methodology to combine external beam and brachytherapy treatments for gynecological neoplasms. Material and Methods: Three dimensional bio-effect treatment planning to obtain complication probability has been outlined. CT scans of the patient's pelvis with the gynecological applicator in place are used to outline normal tissue and tumor volumes. 3D external beam and brachytherapy treatment plans are developed separately and an external beam dose matrix and a brachytherapy dose matrix was calculated. The dose in each voxel was assumed to be homogeneous. The physical dose in each voxel of the dose matrix was then converted into extrapolated response dose (ERD) based on the linear quadratic model that accounts for the dose per fraction, number of fractions, dose rate, and complete or incomplete repair of sublethal damage (time between fractions). The net biological dose delivered was obtained by summing the ERD grids from external beam and brachytherapy since there was complete repair of sublethal damage between external beam and brachytherapy treatments. The normal tissue complication probability and tumor control probability were obtained using the biological dose matrix based on the critical element model. Results: The outlined method of combining external beam and brachytherapy treatments was implemented on gynecological treatments using an applicator for brachytherapy treatments. Conclusion: Implementation of the biological dose calculation that combine different modalities is extremely useful

  14. Beam divergence scaling in neutral beam injectors

    International Nuclear Information System (INIS)

    Holmes, A.J.T.

    1976-01-01

    One of the main considerations in the design of neutral beam injectors is to monimize the divergence of the primary ion beam and hence maximize the beam transport and minimize the input of thermal gas. Experimental measurements of the divergence of a cylindrical ion beam are presented and these measurements are used to analyze the major components of ion beam divergence, namely: space charge expansion, gas-ion scattering, emittance and optical aberrations. The implication of these divergence components in the design of a neutral beam injector system is discussed and a method of maximizing the beam current is described for a given area of source plasma

  15. A Novel Method and Error Analysis for Beam Optics Measurements and Corrections at the Large Hadron Collider

    CERN Document Server

    Langner, Andy Sven; Rossbach, Jörg; Tomás, Rogelio

    2017-02-17

    The Large Hadron Collider (LHC) is currently the world's largest particle accelerator with the highest center of mass energy in particle collision experiments. The control of the particle beam focusing is essential for the performance reach of such an accelerator. For the characterization of the focusing properties at the LHC, turn-by-turn beam position data is simultaneously recorded at numerous measurement devices (BPMs) along the accelerator, while an oscillation is excited on the beam. A novel analysis method for these measurements ($N$-BPM method) is developed here, which is based on a detailed analysis of systematic and statistical error sources and their correlations. It has been applied during the commissioning of the LHC for operation at an unprecedented energy of 6.5 TeV. In this process a stronger focusing than its design specifications has been achieved. This results in smaller transverse beam sizes at the collision points and allows for a higher rate of particle collisions. For the derivation of ...

  16. Multi-Agent Based Beam Search for Real-Time Production Scheduling and Control Method, Software and Industrial Application

    CERN Document Server

    Kang, Shu Gang

    2013-01-01

    The Multi-Agent Based Beam Search (MABBS) method systematically integrates four major requirements of manufacturing production - representation capability, solution quality, computation efficiency, and implementation difficulty - within a unified framework to deal with the many challenges of complex real-world production planning and scheduling problems. Multi-agent Based Beam Search for Real-time Production Scheduling and Control introduces this method, together with its software implementation and industrial applications.  This book connects academic research with industrial practice, and develops a practical solution to production planning and scheduling problems. To simplify implementation, a reusable software platform is developed to build the MABBS method into a generic computation engine.  This engine is integrated with a script language, called the Embedded Extensible Application Script Language (EXASL), to provide a flexible and straightforward approach to representing complex real-world problems. ...

  17. A Corotational Finite Element Method Combined with Floating Frame Method for Large Steady-State Deformation and Free Vibration Analysis of a Rotating-Inclined Beam

    Directory of Open Access Journals (Sweden)

    Ming Hsu Tsai

    2011-01-01

    Full Text Available A corotational finite element method combined with floating frame method and a numerical procedure is proposed to investigate large steady-state deformation and infinitesimal-free vibrationaround the steady-state deformation of a rotating-inclined Euler beam at constant angular velocity. The element nodal forces are derived using the consistent second-order linearization of the nonlinear beam theory, the d'Alembert principle, and the virtual work principle in a current inertia element coordinates, which is coincident with a rotating element coordinate system constructed at the current configuration of the beam element. The governing equations for linear vibration are obtained by the first-order Taylor series expansion of the equation of motion at the position of steady-state deformation. Numerical examples are studied to demonstrate the accuracy and efficiency of the proposed method and to investigate the steady-state deformation and natural frequency of the rotating beam with different inclined angle, angular velocities, radius of the hub, and slenderness ratios.

  18. Chiropractic Adjustment

    Science.gov (United States)

    ... Results Chiropractic adjustment can be effective in treating low back pain, although much of the research done shows only a modest benefit — similar to the results of more conventional treatments. Some studies suggest that spinal manipulation also may ...

  19. Chiropractic Adjustment

    Science.gov (United States)

    ... How you prepare No special preparation is required before a chiropractic adjustment. Chiropractic treatment may require a series of visits to your chiropractor. Ask your care provider about the frequency of visits and be ...

  20. A Projection Quality-Driven Tube Current Modulation Method in Cone-Beam CT for IGRT: Proof of Concept.

    Science.gov (United States)

    Men, Kuo; Dai, Jianrong

    2017-12-01

    To develop a projection quality-driven tube current modulation method in cone-beam computed tomography for image-guided radiotherapy based on the prior attenuation information obtained by the planning computed tomography and then evaluate its effect on a reduction in the imaging dose. The QCKV-1 phantom with different thicknesses (0-400 mm) of solid water upon it was used to simulate different attenuation (μ). Projections were acquired with a series of tube current-exposure time product (mAs) settings, and a 2-dimensional contrast to noise ratio was analyzed for each projection to create a lookup table of mAs versus 2-dimensional contrast to noise ratio, μ. Before a patient underwent computed tomography, the maximum attenuation [Formula: see text] within the 95% range of each projection angle (θ) was estimated according to the planning computed tomography images. Then, a desired 2-dimensional contrast to noise ratio value was selected, and the mAs setting at θ was calculated with the lookup table of mAs versus 2-dimensional contrast to noise ratio,[Formula: see text]. Three-dimensional cone-beam computed tomography images were reconstructed using the projections acquired with the selected mAs. The imaging dose was evaluated with a polymethyl methacrylate dosimetry phantom in terms of volume computed tomography dose index. Image quality was analyzed using a Catphan 503 phantom with an oval body annulus and a pelvis phantom. For the Catphan 503 phantom, the cone-beam computed tomography image obtained by the projection quality-driven tube current modulation method had a similar quality to that of conventional cone-beam computed tomography . However, the proposed method could reduce the imaging dose by 16% to 33% to achieve an equivalent contrast to noise ratio value. For the pelvis phantom, the structural similarity index was 0.992 with a dose reduction of 39.7% for the projection quality-driven tube current modulation method. The proposed method could reduce the

  1. Environmental assessment of disinfection methods by electron beam, UV and ozone using LCA

    International Nuclear Information System (INIS)

    Lee, Kun Mo; Jeong, In Tae; Choi, Yo Han; Kim, Jin Yong; Puruitichaiwiboon, Phirada; Park, Jeong Gun; Baek, Chun Youl; Chun, Yoon Young

    2008-02-01

    It is a research to compare E-Beam radiation as a disinfection facility of effluent from wastewater treatment facility and other type of existing disinfection facility from environmental aspect. Research process: International Standard ISO14044:2006 Life Cycle Assessment Methodology: Eco-indicator 99 Methodology Software: SimaPro 7.1.2(PRe consultant, Netherland) Database: IDEMAT 2001, Ecoinvent system process, Ecoinvent unit process, BUWAL 250 Comparison disinfection facility: UltraViolet disinfection facility, Ozone disinfection facility Result: - E-Beam radiation disinfection facility has superior environmental performance in 7 environmental impact category such as carcinogenic effects, respiratory effects caused by organic substances, respiratory effects caused by inorganic substances, climate change, ozone layer depletion, ecological toxicity and acidification/eutrofication. - The result shows that environmental impact of E-Beam radiation disinfection facility is the smallest among disinfection facilities while 20yrs is given as life time. - The energy used in use stage is key environmental issue. E-beam radiation disinfection facility consumes 320 times less than others in order to achieve reference disinfection ratio (95.4%) with reference flow rate (100,000m 3 /day) condition. - Therefore, more increasing design life time of disinfection facility, superior environmental and economic performance of E-Beam radiation disinfection facility than those of other disinfection facilities

  2. A method for determination of parameters of the initial electron beam hitting the target in linac

    Science.gov (United States)

    Tai, D. T.; Son, N. D.; Loan, T. T. H.; Tuan, H. D.

    2017-05-01

    Detailed characteristics of the electron beam incident on the target of the Linac are almost impossible to be measured. With Monte Carlo technique it is possible to simulate the transport of radiation through the accelerator head and find out the initial beam parameters. These parameters, such as energy spectrum and spatial distribution can be ascertained by matching the simulated dose distributions with the measured dose distributions using trial and error. In this work, a Monte Carlo modeling of the HPD Siemens Primus linear accelerator in 6 MV photon beams at Dong Nai general hospital was performed. The simulated Percent depth doses (PDD) and beam profiles (OCR) were then compared with the measured ones. Excellent agreements were obtained between simulations and measurements with an average difference of 0.7% for PDD less than 2% for OCR. The percentage gamma passing rate is 100% with 1% dose difference and 1 mm distance to agreement as acceptance criteria. The best suited energy and radius of the electron beam incident on the target were found at 6.04 MeV and at FWHM = 1.2 mm respectively.

  3. Systems and methods for detecting an image of an object by use of an X-ray beam having a polychromatic distribution

    Science.gov (United States)

    Parham, Christopher; Zhong, Zhong; Pisano, Etta; Connor, Dean; Chapman, Leroy D.

    2010-06-22

    Systems and methods for detecting an image of an object using an X-ray beam having a polychromatic energy distribution are disclosed. According to one aspect, a method can include detecting an image of an object. The method can include generating a first X-ray beam having a polychromatic energy distribution. Further, the method can include positioning a single monochromator crystal in a predetermined position to directly intercept the first X-ray beam such that a second X-ray beam having a predetermined energy level is produced. Further, an object can be positioned in the path of the second X-ray beam for transmission of the second X-ray beam through the object and emission from the object as a transmitted X-ray beam. The transmitted X-ray beam can be directed at an angle of incidence upon a crystal analyzer. Further, an image of the object can be detected from a beam diffracted from the analyzer crystal.

  4. Isotope separation using tuned laser and electron beam

    International Nuclear Information System (INIS)

    Trajmar, S.

    1987-01-01

    The method for producing and separating a stream of a selected isotope from an atomic beam containing a mixture of isotopes is described comprising the steps of: (a) producing an atomic beam containing the isotope of interest and other isotopes; (b) producing a magnetic field to broaden the energy domain of the individual magnetic sublevels of the isotope of interest and having the atomic beam passing therethrough; (c) producing a laser beam; (d) adjusting the polarization of the laser beam to further maximize the activation of only individual magnetic sublevels of the isotope of interest; (e) aiming the laser beam to strike the atomic beam within the magnetic field and traverse the path of the atomic beam; (f) producing a collimated and high intensity beam of electrons within the magnetic field aimed to strike the atomic beam; and, (g) disposing deflection means to have the atomic beam pass therethrough after being struck by the electron beam and deflect the ionized isotope from the remainder of the beam to form a separate stream composed only of the isotope of interest

  5. Thermal diffusivity measurement in thin metallic filaments using the mirage method with multiple probe beams and a digital camera

    Science.gov (United States)

    Vargas, E.; Cifuentes, A.; Alvarado, S.; Cabrera, H.; Delgado, O.; Calderón, A.; Marín, E.

    2018-02-01

    Photothermal beam deflection is a well-established technique for measuring thermal diffusivity. In this technique, a pump laser beam generates temperature variations on the surface of the sample to be studied. These variations transfer heat to the surrounding medium, which may be air or any other fluid. The medium in turn experiences a change in the refractive index, which will be proportional to the temperature field on the sample surface when the distance to this surface is small. A probe laser beam will suffer a deflection due to the refractive index periodical changes, which is usually monitored by means of a quadrant photodetector or a similar device aided by lock-in amplification. A linear relationship that arises in this technique is that given by the phase lag of the thermal wave as a function of the distance to a punctual heat source when unidimensional heat diffusion can be guaranteed. This relationship is useful in the calculation of the sample's thermal diffusivity, which can be obtained straightforwardly by the so-called slope method, if the pump beam modulation frequency is well-known. The measurement procedure requires the experimenter to displace the probe beam at a given distance from the heat source, measure the phase lag at that offset, and repeat this for as many points as desired. This process can be quite lengthy in dependence of the number points. In this paper, we propose a detection scheme, which overcomes this limitation and simplifies the experimental setup using a digital camera that substitutes all detection hardware utilizing motion detection techniques and software digital signal lock-in post-processing. In this work, the method is demonstrated using thin metallic filaments as samples.

  6. An effective method for detection and analysis of DNA damage induced by heavy-ion beams

    International Nuclear Information System (INIS)

    Kazama, Y.; Saito, H.; Fujiwara, M.; Matsuyama, T.; Hayashi, Y.; Ryuto, H.; Fukunishi, N.; Abe, T.

    2007-01-01

    We have developed an efficient system to detect and analyze DNA mutations induced by heavy-ion beams in Arabidopsis thaliana. In this system, a stable transgenic Arabidopsis line that constitutively expresses a yellow fluorescent protein (YFP) by a single-copy gene at a genomic locus was constructed and irradiated with heavy-ion beams. The YFP gene is a target of mutagenesis, and its loss of function or expression can easily be detected by the disappearance of YFP signals in planta under microscopy. With this system, a sup(12)Csup(6+)- induced mutant with single deletion and multiple base changes was isolated

  7. RELIABILITY ANALYSIS OF A STEEL BEAM USING THE MONTE CARLO METHOD

    OpenAIRE

    Klink, Beatriz Gonçalves; da Silva, Lara Alves

    2017-01-01

    paper aims to show the feasibility of structural analysis in steel beams, basedon the precepts of reliability. We assessed the reliability and security of a steel I-beam profile (I 254 (10”) x 37,7), MR250, subject to an applied bending moment. The purpose was to evaluate the appropriateness of the component in handling specific project stresses. First we provide a dimensioning analysis based on Brazilian structural standards and then a verification of the beam’s relative safety, in terms of ...

  8. Two-Screen Method for Determining Electron Beam Energy and Deflection from Laser Wakefield Acceleration

    Energy Technology Data Exchange (ETDEWEB)

    Pollock, B B; Ross, J S; Tynan, G R; Divol, L; Glenzer, S H; Leurent, V; Palastro, J P; Ralph, J E; Froula, D H; Clayton, C E; Marsh, K A; Pak, A E; Wang, T L; Joshi, C

    2009-04-24

    Laser Wakefield Acceleration (LWFA) experiments have been performed at the Jupiter Laser Facility, Lawrence Livermore National Laboratory. In order to unambiguously determine the output electron beam energy and deflection angle at the plasma exit, we have implemented a two-screen electron spectrometer. This system is comprised of a dipole magnet followed by two image plates. By measuring the electron beam deviation from the laser axis on each plate, both the energy and deflection angle at the plasma exit are determined through the relativistic equation of motion.

  9. Spot-scanning beam delivery with laterally- and longitudinally-mixed spot size pencil beams in heavy ion radiotherapy

    Science.gov (United States)

    Yan, Yuan-Lin; Liu, Xin-Guo; Dai, Zhong-Ying; Ma, Yuan-Yuan; He, Peng-Bo; Shen, Guo-Sheng; Ji, Teng-Fei; Zhang, Hui; Li, Qiang

    2017-09-01

    The three-dimensional (3D) spot-scanning method is one of the most commonly used irradiation methods in charged particle beam radiotherapy. Generally, spot-scanning beam delivery utilizes the same size pencil beam to irradiate the tumor targets. Here we propose a spot-scanning beam delivery method with laterally- and longitudinally-mixed size pencil beams for heavy ion radiotherapy. This uses pencil beams with a bigger spot size in the lateral direction and wider mini spread-out Bragg peak (mini-SOBP) to irradiate the inner part of a target volume, and pencil beams with a smaller spot size in the lateral direction and narrower mini-SOBP to irradiate the peripheral part of the target volume. Instead of being controlled by the accelerator, the lateral size of the pencil beam was adjusted by inserting Ta scatterers in the beam delivery line. The longitudinal size of the pencil beam (i.e. the width of the mini-SOBP) was adjusted by tilting mini ridge filters along the beam direction. The new spot-scanning beam delivery using carbon ions was investigated theoretically and compared with traditional spot-scanning beam delivery. Our results show that the new spot-scanning beam delivery has smaller lateral penumbra, steeper distal dose fall-off and the dose homogeneity (1-standard deviation/mean) in the target volume is better than 95%. Supported by Key Project of National Natural Science Foundation of China (U1232207), National Key Technology Support Program of the Ministry of Science and Technology of China (2015BAI01B11), National Key Research and Development Program of the Ministry of Science and Technology of China (2016YFC0904602) and National Natural Science Foundation of China (11075191, 11205217, 11475231, 11505249)

  10. Beam geometry selection using sequential beam addition

    Energy Technology Data Exchange (ETDEWEB)

    Popple, Richard A., E-mail: rpopple@uabmc.edu; Brezovich, Ivan A.; Fiveash, John B. [Department of Radiation Oncology, The University of Alabama at Birmingham, 1720 2nd Avenue South, Birmingham, Alabama 35294 (United States)

    2014-05-15

    Purpose: The selection of optimal beam geometry has been of interest since the inception of conformal radiotherapy. The authors report on sequential beam addition, a simple beam geometry selection method, for intensity modulated radiation therapy. Methods: The sequential beam addition algorithm (SBA) requires definition of an objective function (score) and a set of candidate beam geometries (pool). In the first iteration, the optimal score is determined for each beam in the pool and the beam with the best score selected. In the next iteration, the optimal score is calculated for each beam remaining in the pool combined with the beam selected in the first iteration, and the best scoring beam is selected. The process is repeated until the desired number of beams is reached. The authors selected three treatment sites, breast, lung, and brain, and determined beam arrangements for up to 11 beams from a pool comprised of 25 equiangular transverse beams. For the brain, arrangements were additionally selected from a pool of 22 noncoplanar beams. Scores were determined for geometries comprised equiangular transverse beams (EQA), as well as two tangential beams for the breast case. Results: In all cases, SBA resulted in scores superior to EQA. The breast case had the strongest dependence on beam geometry, for which only the 7-beam EQA geometry had a score better than the two tangential beams, whereas all SBA geometries with more than two beams were superior. In the lung case, EQA and SBA scores monotonically improved with increasing number of beams; however, SBA required fewer beams to achieve scores equivalent to EQA. For the brain case, SBA with a coplanar pool was equivalent to EQA, while the noncoplanar pool resulted in slightly better scores; however, the dose-volume histograms demonstrated that the differences were not clinically significant. Conclusions: For situations in which beam geometry has a significant effect on the objective function, SBA can identify

  11. Histological validation of cone-beam computed tomography versus laser fluorescence and conventional diagnostic methods for occlusal caries detection.

    Science.gov (United States)

    Ozturk, Elif; Sinanoglu, Alper

    2015-02-01

    The purpose of this study was to compare the validity of visual (VE), radiological (RE), cone beam computed tomography (CBCT), and laser fluorescence (LFE) examination methods for the detection of the occlusal noncavitated caries in permanent posterior teeth. Two examiners assessed 121 selected sites on the occlusal surfaces of 44 molar teeth by visual (International Caries Assessment and Detection System II [ICDAS]), radiographic (bite-wing projection) cone-beam computed tomography, and laser fluorescence (DIAGNOdent Pen) examination methods. After a 1-week interval, each measurement was repeated by two examiners. Then, the teeth were sectioned, and histological evaluation was performed, which serves as the gold standard. The lesion depths were classified and correlated with the methods evaluated for validation. The intra- and inter-examiner reliability (sensitivity, specificity) and reproducibility of all examination methods were calculated using a weighted Cohen's κ statistic. The correlation between the examination methods was determined using receiver operating characteristic (ROC) analysis indicating the area under the curve (AUC). CBCT exhibited excellent intra-examiner (0.76 for examiner 1, 0.78 for examiner 2) and fair to good inter-examiner (0.63 for the first, 0.64 for the second measurements) reproducibility. The intra-examiner reproducibility was excellent for the LFE method according to the weighted κ values of examiners 1 (0.90) and 2 (0.79). Among the combined methods, the highest AUC values (0.81-0.95) were obtained for the CBCT examination method performed by the two examiners at both the first and second measurements. Cone beam computed tomography showed better performance than other diagnostic methods.

  12. Evaluation of paediatric cardiosurgical model in Croatia by using the Aristotle basic complexity score and the risk adjustment for congenital cardiac surgery-1 method.

    Science.gov (United States)

    Dilber, Daniel; Malcic, Ivan

    2010-08-01

    The Aristotle basic complexity score and the risk adjustment in congenital cardiac surgery-1 method were developed and used to compare outcomes of congenital cardiac surgery. Both methods were used to compare results of procedures performed on our patients in Croatian cardiosurgical centres and results of procedures were taken abroad. The study population consisted of all patients with congenital cardiac disease born to Croatian residents between 1 October, 2002 and 1 October, 2007 undergoing a cardiovascular operation during this period. Of the 556 operations, the Aristotle basic complexity score could be assigned to 553 operations and the risk adjustment in congenital cardiac surgery-1 method to 536 operations. Procedures were performed in two institutions in Croatia and seven institutions abroad. The average complexity for cardiac procedures performed in Croatia was significantly lower. With both systems, along with the increase in complexity, there is also an increase in mortality before discharge and postoperative length of stay. Only after the adjustment for complexity there are marked differences in mortality and occurrence of postoperative complications. Both, the Aristotle basic complexity score and the risk adjustment in congenital cardiac surgery-1 method were predictive of in-hospital mortality as well as prolonged postoperative length to stay, and can be used as a tool in our country to evaluate a cardiosurgical model and recognise potential problems.

  13. Longwall mining “cutting cantilever beam theory” and 110 mining method in China—The third mining science innovation

    OpenAIRE

    Manchao He; Guolong Zhu; Zhibiao Guo

    2015-01-01

    With the third innovation in science and technology worldwide, China has also experienced this marvelous progress. Concerning the longwall mining in China, the “masonry beam theory” (MBT) was first proposed in the 1960s, illustrating that the transmission and equilibrium method of overburden pressure using reserved coal pillar in mined-out areas can be realized. This forms the so-called “121 mining method”, which lays a solid foundation for development of mining science and technology in Chin...

  14. Two methods to improve the accuracy of target-strength estimates for horizontal beaming

    Czech Academy of Sciences Publication Activity Database

    Rakowitz, G.; Herold, W.; Fesl, Ch.; Keckeis, H.; Kubečka, Jan; Balk, H.

    2008-01-01

    Roč. 93, č. 3 (2008), s. 324-331 ISSN 0165-7836 Institutional research plan: CEZ:AV0Z60170517 Keywords : shallow water acoustics * horizontal beaming * target strength variability * flash-effect * side-aspect * Cyprinids Subject RIV: GL - Fishing Impact factor: 1.434, year: 2008

  15. New method of contour image processing based on the formalism of spiral light beams

    Energy Technology Data Exchange (ETDEWEB)

    Volostnikov, Vladimir G; Kishkin, S A; Kotova, S P [Samara Branch of the P.N. Lebedev Physical Institute, Russian Academy of Sciences, Samara (Russian Federation)

    2013-07-31

    The possibility of applying the mathematical formalism of spiral light beams to the problems of contour image recognition is theoretically studied. The advantages and disadvantages of the proposed approach are evaluated; the results of numerical modelling are presented. (optical image processing)

  16. Wavefront-sensor-induced beam size error: physical mechanism, sensitivity-analysis and correction method

    NARCIS (Netherlands)

    Koek, W.D.; Zwet, E.J. van

    2015-01-01

    When using a commonly-used quadri-wave lateral shearing interferometer wavefront sensor (QWLSI WFS) for beam size measurements on a high power CO2 laser, artefacts have been observed in the measured irradiance distribution. The grating in the QWLSI WFS not only generates the diffracted first orders

  17. Corrections in the gold foil activation method for determination of neutron beam density

    DEFF Research Database (Denmark)

    Als-Nielsen, Jens Aage

    1967-01-01

    A finite foil thickness and deviation in the cross section from the 1ν law imply corrections in the determination of neutron beam densities by means of foil activation. These corrections, which depend on the neutron velocity distribution, have been examined in general and are given in a specific...

  18. Modified knife-edge method for current density distribution measurements in e-beam writers

    Czech Academy of Sciences Publication Activity Database

    Bok, Jan; Kolařík, Vladimír; Horáček, Miroslav; Matějka, Milan; Matějka, František

    2013-01-01

    Roč. 31, č. 3 (2013), 031603:1-6 ISSN 1071-1023 R&D Projects: GA MŠk ED0017/01/01; GA TA ČR TE01020118 Institutional support: RVO:68081731 Keywords : electron-beam * intensity distribution * aperture * detector * profile * size Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 1.358, year: 2013

  19. A Novel Location-Awareness Method Using CubeSats for Locating the Spot Beam Emitters of Geostationary Communications Satellites

    Directory of Open Access Journals (Sweden)

    Weicai Yang

    2018-01-01

    Full Text Available As more spacecraft are launched into the Geostationary Earth Orbit (GEO belt, the possibility of fatal collisions or unnecessary interference between spacecraft increases. In this paper, a new location-awareness method that uses CubeSats is proposed to assist with radiofrequency (RF domain verification by means of awareness and identification of the positions of the spot beam emitters of communications satellites in geostationary orbit. By flying a CubeSat (or a constellation of CubeSats through the coverage area of a spot beam, the spot beam emitter’s position is identified and the spot beam’s pattern knowledge is characterized. The geometry, the equations of motion of the spacecraft, the measurement process, and the filtering equations in a location system are addressed with respect to the location methods investigated in this study. A realistic scenario in which a CubeSat receives signals from GEO communications satellites is simulated using the Systems Tool Kit (STK. The results of the simulation and the analysis presented in this study provide a thorough verification of the performance of the location-awareness method.

  20. Beam geometry selection using sequential beam addition.

    Science.gov (United States)

    Popple, Richard A; Brezovich, Ivan A; Fiveash, John B

    2014-05-01

    The selection of optimal beam geometry has been of interest since the inception of conformal radiotherapy. The authors report on sequential beam addition, a simple beam geometry selection method, for intensity modulated radiation therapy. The sequential beam addition algorithm (SBA) requires definition of an objective function (score) and a set of candidate beam geometries (pool). In the first iteration, the optimal score is determined for each beam in the pool and the beam with the best score selected. In the next iteration, the optimal score is calculated for each beam remaining in the pool combined with the beam selected in the first iteration, and the best scoring beam is selected. The process is repeated until the desired number of beams is reached. The authors selected three treatment sites, breast, lung, and brain, and determined beam arrangements for up to 11 beams from a pool comprised of 25 equiangular transverse beams. For the brain, arrangements were additionally selected from a pool of 22 noncoplanar beams. Scores were determined for geometries comprised equiangular transverse beams (EQA), as well as two tangential beams for the breast case. In all cases, SBA resulted in scores superior to EQA. The breast case had the strongest dependence on beam geometry, for which only the 7-beam EQA geometry had a score better than the two tangential beams, whereas all SBA geometries with more than two beams were superior. In the lung case, EQA and SBA scores monotonically improved with increasing number of beams; however, SBA required fewer beams to achieve scores equivalent to EQA. For the brain case, SBA with a coplanar pool was equivalent to EQA, while the noncoplanar pool resulted in slightly better scores; however, the dose-volume histograms demonstrated that the differences were not clinically significant. For situations in which beam geometry has a significant effect on the objective function, SBA can identify arrangements equivalent to equiangular

  1. Improving the Process of Adjusting the Parameters of Finite Element Models of Healthy Human Intervertebral Discs by the Multi-Response Surface Method

    Science.gov (United States)

    Somovilla Gómez, Fátima

    2017-01-01

    The kinematic behavior of models that are based on the finite element method (FEM) for modeling the human body depends greatly on an accurate estimate of the parameters that define such models. This task is complex, and any small difference between the actual biomaterial model and the simulation model based on FEM can be amplified enormously in the presence of nonlinearities. The current paper attempts to demonstrate how a combination of the FEM and the MRS methods with desirability functions can be used to obtain the material parameters that are most appropriate for use in defining the behavior of Finite Element (FE) models of the healthy human lumbar intervertebral disc (IVD). The FE model parameters were adjusted on the basis of experimental data from selected standard tests (compression, flexion, extension, shear, lateral bending, and torsion) and were developed as follows: First, three-dimensional parameterized FE models were generated on the basis of the mentioned standard tests. Then, 11 parameters were selected to define the proposed parameterized FE models. For each of the standard tests, regression models were generated using MRS to model the six stiffness and nine bulges of the healthy IVD models that were created by changing the parameters of the FE models. The optimal combination of the 11 parameters was based on three different adjustment criteria. The latter, in turn, were based on the combination of stiffness and bulges that were obtained from the standard test FE simulations. The first adjustment criteria considered stiffness and bulges to be equally important in the adjustment of FE model parameters. The second adjustment criteria considered stiffness as most important, whereas the third considered the bulges to be most important. The proposed adjustment methods were applied to a medium-sized human IVD that corresponded to the L3–L4 lumbar level with standard dimensions of width = 50 mm, depth = 35 mm, and height = 10 mm. Agreement between the

  2. Methods and approaches to provide feedback from nuclear and covariance data adjustment for improvement of nuclear data files. SG39 meeting, May 2014

    International Nuclear Information System (INIS)

    Aliberti, G.; Archier, P.; Dunn, M.; Dupont, E.; Hill, I.; ); Garcia, A.; Hursin, M.; Pelloni, S.; Ivanova, T.; Kodeli, I.; Palmiotti, G.; Salvatores, M.; Touran, N.; Wenming, Wang; Yokoyama, K.

    2014-05-01

    The aim of WPEC subgroup 39 'Methods and approaches to provide feedback from nuclear and covariance data adjustment for improvement of nuclear data files' is to provide criteria and practical approaches to use effectively the results of sensitivity analyses and cross section adjustments for feedback to evaluators and differential measurement experimentalists in order to improve the knowledge of neutron cross sections, uncertainties, and correlations to be used in a wide range of applications. This document is the proceedings of the second Subgroup meeting, held at the NEA, Issy-les-Moulineaux, France, on 13 May 2014. It comprises a Summary Record of the meeting and all the available presentations (slides) given by the participants: A - Welcome: Review of actions (M. Salvatores); B - Inter-comparison of sensitivity coefficients: 1 - Sensitivity Computation with Monte Carlo Methods (T. Ivanova); 2 - Sensitivity analysis of FLATTOP-Pu (I. Kodeli); 3 - Sensitivity coefficients by means of SERPENT-2 (S. Pelloni); 4 - Demonstration - Database for ICSBEP (DICE) and Database and Analysis Tool for IRPhE (IDAT) (I. Hill); C - Specific new experiments: 1 - PROTEUS FDWR-II (HCLWR) program summary (M. Hursin); 2 - STEK and SEG Experiments, M. Salvatores 3 - Experiments related to 235 U, 238 U, 56 Fe and 23 Na, G. Palmiotti); 4 - Validation of Iron Cross Sections against ASPIS Experiments (JEF/DOC-420) (I. Kodeli); 5 - Benchmark analysis of Iron Cross-sections (EFFDOC-1221) (I. Kodeli 6 - Integral Beta-effective Measurements (K. Yokoyama on behalf of M. Ishikawa); D - Adjustment results: 1 - Impacts of Covariance Data and Interpretation of Adjustment Trends of ADJ2010, (K. Yokoyama); 2 - Revised Recommendations from ADJ2010 Adjustment (K. Yokoyama); 3 - Comparisons and Discussions on Adjustment trends from JEFF (CEA) (P. Archier); 4 - Feedback on CIELO Isotopes from ENDF/B-VII.0 Adjustment (G. Palmiotti); 5 - Demonstration - Plot comparisons of participants

  3. The application of Monte Carlo method to electron and photon beams transport; Zastosowanie metody Monte Carlo do analizy transportu elektronow i fotonow

    Energy Technology Data Exchange (ETDEWEB)

    Zychor, I. [Soltan Inst. for Nuclear Studies, Otwock-Swierk (Poland)

    1994-12-31

    The application of a Monte Carlo method to study a transport in matter of electron and photon beams is presented, especially for electrons with energies up to 18 MeV. The SHOWME Monte Carlo code, a modified version of GEANT3 code, was used on the CONVEX C3210 computer at Swierk. It was assumed that an electron beam is mono directional and monoenergetic. Arbitrary user-defined, complex geometries made of any element or material can be used in calculation. All principal phenomena occurring when electron beam penetrates the matter are taken into account. The use of calculation for a therapeutic electron beam collimation is presented. (author). 20 refs, 29 figs.

  4. Identifying the contents of a type 1 diabetes outpatient care program based on the self-adjustment of insulin using the Delphi method.

    Science.gov (United States)

    Kubota, Mutsuko; Shindo, Yukari; Kawaharada, Mariko

    2014-10-01

    The objective of this study is to identify the items necessary for an outpatient care program based on the self-adjustment of insulin for type 1 diabetes patients. Two surveys based on the Delphi method were conducted. The survey participants were 41 certified diabetes nurses in Japan. An outpatient care program based on the self-adjustment of insulin was developed based on pertinent published work and expert opinions. There were a total of 87 survey items in the questionnaire, which was developed based on the care program mentioned earlier, covering matters such as the establishment of prerequisites and a cooperative relationship, the basics of blood glucose pattern management, learning and practice sessions for the self-adjustment of insulin, the implementation of the self-adjustment of insulin, and feedback. The participants' approval on items in the questionnaires was defined at 70%. Participants agreed on all of the items in the first survey. Four new parameters were added to make a total of 91 items for the second survey and participants agreed on the inclusion of 84 of them. Items necessary for a type 1 diabetes outpatient care program based on self-adjustment of insulin were subsequently selected. It is believed that this care program received a fairly strong approval from certified diabetes nurses; however, it will be necessary to have the program further evaluated in conjunction with intervention studies in the future. © 2014 The Authors. Japan Journal of Nursing Science © 2014 Japan Academy of Nursing Science.

  5. Principles of alignment of multi-beam lasers for thermonuclear purposes

    International Nuclear Information System (INIS)

    Basov, N.G.; Belyan, B.F.; Zhilkin, G.P.

    1978-01-01

    The problems of methods and equipment for power pulse laser adjustment, as well as the problem of adjustment automatization are considered. The adjustment of a power 12-channel ''Dolphin'' laser installation on the neodymium glass is taken as a concrete object. The adjustment objects are optical track of laser installation, guidance and laser radiation focusing system on the target, the system of target delivery to the focal volume, control system of element optical quality of laser installation and laser beams, as well as target radiation conditions in vacuum chamber. List of requirements of adjustment beams, possible sources of adjustment beams, equipment complex and laser installation adjustment methods are considered. The principles and scheme solutions of automatic adjustment of optical elements are discussed and the description of working samples of automatic joints is given. The problem of working laser beams imitation by adjusting and the possibilities of automatization of laser radiation space-angle characteristics control are considered. The control scheme of adjustment processes with computer as well as the switching on of adjustment automatic subsystem in the general automatization scheme of the ''Dolphin'' installation are discussed

  6. Influence of the beam energy on the sensitivity of the PIXE methods applied to the detection of Pb in air

    International Nuclear Information System (INIS)

    Caridi, Aurora; Debray, Mario; Hojman, Daniel; Kreiner, A.J.; Santos, Daniel

    1989-01-01

    The air pollution by lead at the downtown area of Buenos Aires city was studied applying the PIXE method. The samples were collected at different seasons of the year. An appreciable reduction of the Pb content was observed on holidays and in summer when there is a lot less of cars in the streets. The influence of the beam energy on the Bremsstrahlung background was studied in order to optimize the sensitivity of the method. The C-12 beam energy was varied from 54 MeV to 30 MeV. The maximum Bremsstrahlung energy of secondary electrons decreased from 10 keV to 5.5 keV. Simultaneously the background radiation was appreciably reduced in the whole spectrum for the lowest beam energy whereas the values for the cross section of X ray production in the Pb L shell were no substantially modified. It is concluded that it is possible to analyze those elements whose characteristic X rays have an energy larger than 5.5 keV. (Author) [es

  7. Application of Microwave Methods for Characterization of NEG Coatings and Obstacle Detection in Accelerator Beam-pipes

    CERN Document Server

    Seebacher, David

    2009-01-01

    In many particle accelerators, including the LHC at the European Organization for Nuclear Research CERN, NEG coatings are used to improve vacuum performance. In other particle accelerators there have been hints that those coatings could have a relevant impact on the beam coupling impedance, however the data available is contradictory. To clarify the possible impact of NEG coatings the electromagnetic properties have been measured. The measurements have been carried out by means of cavity perturbation method. The second part of this thesis deals with the microwave waveguide reflectometer developed at CERN several years ago, which is used as part of the quality assurance test program for the LHC assembly. To ensure optimum operation and to avoid an expensive removal of any foreign object from inside the LHC beam-screen after its completion, microwave reflectometry is performed. Until now several objects have been found by means of reflectometry, but so far neither precise data about the reflections of different...

  8. Synthesis and structure of Ag-Si nanoparticles obtained by the electron-beam evaporation/condensation method

    Science.gov (United States)

    Nomoev, A. V.; Bardakhanov, S. P.

    2012-04-01

    Metal-semiconductor composite Ag-Si nanostructures, including Ag/Si core-shell nanoparticles, have been synthesized for the first time by a high-efficiency evaporation/condensation method using relativistic electron beam. In the Ag/Si core-shell nanoparticles, the core is crystalline, while the shell consists of amorphous silicon. It is found that the synthesis of these particles requires taking into account the difference in the saturated vapor pressures of evaporated components. The dependences of the particle size on the electron beam power at the evaporation stage and the pressure of argon at the condensation stage have been studied. It is established that (i) the main process of Ag/Si nanoparticle formation is coagulation and (ii) the Si shell formation decreases the size of particles.

  9. Beam-beam effects in the Tevatron

    Energy Technology Data Exchange (ETDEWEB)

    Shiltsev, V.; Alexahin, Y.; Lebedev, V.; Lebrun, P.; Moore, R.S.; Sen, T.; Tollestrup, A.; Valishev, A.; Zhang, X.L.; /Fermilab

    2005-01-01

    The Tevatron in Collider Run II (2001-present) is operating with 6 times more bunches, many times higher beam intensities and luminosities than in Run I (1992-1995). Electromagnetic long-range and head-on interactions of high intensity proton and antiproton beams have been significant sources of beam loss and lifetime limitations. We present observations of the beam-beam phenomena in the Tevatron and results of relevant beam studies. We analyze the data and various methods employed in operations, predict the performance for planned luminosity upgrades, and discuss ways to improve it.

  10. Method and apparatus for secondary laser pumping by electron beam excitation

    Science.gov (United States)

    George, E. Victor; Krupke, William F.; Murray, John R.; Powell, Howard T.; Swingle, James C.; Turner, Jr., Charles E.; Rhodes, Charles K.

    1978-01-01

    An electron beam of energy typically 100 keV excites a fluorescer gas which emits ultraviolet radiation. This radiation excites and drives an adjacent laser gas by optical pumping or photolytic dissociation to produce high efficiency pulses. The invention described herein was made in the course of, or under, United States Energy Research and Development Administration Contract No. W-7405-Eng-48 with the University of California.

  11. Graft-copolymerization of polyethersulfone microporous membrane with electron beam simultaneous irradiation method

    International Nuclear Information System (INIS)

    Han Zhaolei; Meng Fanxia; Wang Yongxia; Liu Xiaoguang; Wang Rong

    2010-01-01

    Polyethersulfone(PES) microporous membrane was grafted with methacrylic acid under electron beam irradiation. Controlling the monomer concentration or the absorbed dose, the relationships of the degree of grafting with the monomer concentration and the absorbed dose were obtained for optimum the monomer concentration and absorbed dose. The grafted membrane was characterized by FT-IR and SEM, and the hydrophilicity contact angle of the membrane was tested. (authors)

  12. Comparing Free-Free and Shaker Table Model Correlation Methods Using Jim Beam

    Science.gov (United States)

    Ristow, James; Smith, Kenneth Wayne, Jr.; Johnson, Nathaniel; Kinney, Jackson

    2018-01-01

    Finite element model correlation as part of a spacecraft program has always been a challenge. For any NASA mission, the coupled system response of the spacecraft and launch vehicle can be determined analytically through a Coupled Loads Analysis (CLA), as it is not possible to test the spacecraft and launch vehicle coupled system before launch. The value of the CLA is highly dependent on the accuracy of the frequencies and mode shapes extracted from the spacecraft model. NASA standards require the spacecraft model used in the final Verification Loads Cycle to be correlated by either a modal test or by comparison of the model with Frequency Response Functions (FRFs) obtained during the environmental qualification test. Due to budgetary and time constraints, most programs opt to correlate the spacecraft dynamic model during the environmental qualification test, conducted on a large shaker table. For any model correlation effort, the key has always been finding a proper definition of the boundary conditions. This paper is a correlation case study to investigate the difference in responses of a simple structure using a free-free boundary, a fixed boundary on the shaker table, and a base-drive vibration test, all using identical instrumentation. The NAVCON Jim Beam test structure, featured in the IMAC round robin modal test of 2009, was selected as a simple, well recognized and well characterized structure to conduct this investigation. First, a free-free impact modal test of the Jim Beam was done as an experimental control. Second, the Jim Beam was mounted to a large 20,000 lbf shaker, and an impact modal test in this fixed configuration was conducted. Lastly, a vibration test of the Jim Beam was conducted on the shaker table. The free-free impact test, the fixed impact test, and the base-drive test were used to assess the effect of the shaker modes, evaluate the validity of fixed-base modeling assumptions, and compare final model correlation results between these

  13. Analytic methods to find beating transitions of asymmetric Gaussian beams in GNLS equations

    Science.gov (United States)

    Ianetz, David; Schiff, Jeremy

    2018-01-01

    In a simple model of propagation of asymmetric Gaussian beams in nonlinear waveguides, described by a reduction to ordinary differential equations of generalized nonlinear Schrödinger equations with cubic-quintic (CQ) and saturable (SAT) nonlinearities and a graded-index profile, the beam widths exhibit two different types of beating behavior, with transitions between them. We present an analytic model to explain these phenomena, which originate in a 1:1 resonance in a 2 degree-of-freedom Hamiltonian system. We show how small oscillations near a fixed point close to 1:1 resonance in such a system can be approximated using an integrable Hamiltonian and, ultimately, a single first order differential equation. In particular, the beating transitions can be located from coincidences of roots of a pair of quadratic equations, with coefficients determined (in a highly complex manner) by the internal parameters and initial conditions of the original system. The results of the analytic model agree with the numerics of the original system over large parameter ranges, and allow new predictions that can be verified directly. In the CQ case, we identify a band of beam energies for which there is only a single beating transition (as opposed to 0 or 2) as the eccentricity is increased. In the SAT case, we explain the sudden (dis)appearance of beating transitions for certain values of the other parameters as the grade-index is changed.

  14. Evaluation of Algebraic Iterative Image Reconstruction Methods for Tetrahedron Beam Computed Tomography Systems

    Directory of Open Access Journals (Sweden)

    Joshua Kim

    2013-01-01

    Full Text Available Tetrahedron beam computed tomography (TBCT performs volumetric imaging using a stack of fan beams generated by a multiple pixel X-ray source. While the TBCT system was designed to overcome the scatter and detector issues faced by cone beam computed tomography (CBCT, it still suffers the same large cone angle artifacts as CBCT due to the use of approximate reconstruction algorithms. It has been shown that iterative reconstruction algorithms are better able to model irregular system geometries and that algebraic iterative algorithms in particular have been able to reduce cone artifacts appearing at large cone angles. In this paper, the SART algorithm is modified for the use with the different TBCT geometries and is tested using both simulated projection data and data acquired using the TBCT benchtop system. The modified SART reconstruction algorithms were able to mitigate the effects of using data generated at large cone angles and were also able to reconstruct CT images without the introduction of artifacts due to either the longitudinal or transverse truncation in the data sets. Algebraic iterative reconstruction can be especially useful for dual-source dual-detector TBCT, wherein the cone angle is the largest in the center of the field of view.

  15. Dynamic analysis of smart composite beams by using the frequency domain spectral element method

    Energy Technology Data Exchange (ETDEWEB)

    Park, Il Wook; Lee, Usik [Inha Univ., Incheon (Korea, Republic of)

    2012-08-15

    To excite or measure the dynamic responses of a laminated composite structure for the active controls of vibrations or noises, wafertype piezoelectric transducers are often bonded on the surface of the composite structure to form a multi layer smart composite structure. Thus, for such smart composite structures, it is very important to develop and use a very reliable mathematical and/or computational model for predicting accurate dynamic characteristics. In this paper, the axial-bending coupled equations of motion and boundary conditions are derived for two layer smart composite beams by using the Hamilton's principle with Lagrange multipliers. The spectral element model is then formulated in the frequency domain by using the variation approach. Through some numerical examples, the extremely high accuracy of the present spectral element model is verified by comparing with the solutions by the conventional finite element model provided in this paper. The effects of the lay up of composite laminates and surface bonded wafer type piezoelectric (PZT) layer on the dynamics and wave characteristics of smart composite beams are investigated. The effective constraint forces at the interface between the base beam and PZT layer are also investigated via Lagrange multipliers.

  16. Analytic methods to find beating transitions of asymmetric Gaussian beams in GNLS equations.

    Science.gov (United States)

    Ianetz, David; Schiff, Jeremy

    2018-01-01

    In a simple model of propagation of asymmetric Gaussian beams in nonlinear waveguides, described by a reduction to ordinary differential equations of generalized nonlinear Schrödinger equations with cubic-quintic (CQ) and saturable (SAT) nonlinearities and a graded-index profile, the beam widths exhibit two different types of beating behavior, with transitions between them. We present an analytic model to explain these phenomena, which originate in a 1:1 resonance in a 2 degree-of-freedom Hamiltonian system. We show how small oscillations near a fixed point close to 1:1 resonance in such a system can be approximated using an integrable Hamiltonian and, ultimately, a single first order differential equation. In particular, the beating transitions can be located from coincidences of roots of a pair of quadratic equations, with coefficients determined (in a highly complex manner) by the internal parameters and initial conditions of the original system. The results of the analytic model agree with the numerics of the original system over large parameter ranges, and allow new predictions that can be verified directly. In the CQ case, we identify a band of beam energies for which there is only a single beating transition (as opposed to 0 or 2) as the eccentricity is increased. In the SAT case, we explain the sudden (dis)appearance of beating transitions for certain values of the other parameters as the grade-index is changed.

  17. Salary adjustments

    CERN Multimedia

    HR Department

    2008-01-01

    In accordance with decisions taken by the Finance Committee and Council in December 2007, salaries are adjusted with effect from 1 January 2008. Scale of basic salaries and scale of stipends paid to fellows (Annex R A 5 and R A 6 respectively): increased by 0.71% with effect from 1 January 2008. As a result of the stability of the Geneva consumer price index, following elements do not increase: a) Family Allowance, Child Allowance and Infant Allowance (Annex R A 3). b) Reimbursement of education fees: maximum amounts of reimbursement (Annex R A 4.01) for the academic year 2007/2008. Related adjustments will be implemented, wherever applicable, to Paid Associates and Students. As in the past, the actual percentage increase of each salary position may vary, due to the application of a constant step value and the rounding effects. Human Resources Department Tel. 73566

  18. Salary adjustments

    CERN Multimedia

    HR Department

    2008-01-01

    In accordance with decisions taken by the Finance Committee and Council in December 2007, salaries are adjusted with effect from 1 January 2008. Scale of basic salaries and scale of stipends paid to fellows (Annex R A 5 and R A 6 respectively): increased by 0.71% with effect from 1 January 2008. As a result of the stability of the Geneva consumer price index, the following elements do not increase: a)\tFamily Allowance, Child Allowance and Infant Allowance (Annex R A 3); b)\tReimbursement of education fees: maximum amounts of reimbursement (Annex R A 4.01) for the academic year 2007/2008. Related adjustments will be applied, wherever applicable, to Paid Associates and Students. As in the past, the actual percentage increase of each salary position may vary, due to the application of a constant step value and rounding effects. Human Resources Department Tel. 73566

  19. Labor productivity adjustment factors. A method for estimating labor construction costs associated with physical modifications to nuclear power plants

    International Nuclear Information System (INIS)

    Riordan, B.J.

    1986-03-01

    This report develops quantitative labor productivity adjustment factors for the performance of regulatory impact analyses (RIAs). These factors will allow analysts to modify ''new construction'' labor costs to account for changes in labor productivity due to differing work environments at operating reactors and at reactors with construction in progress. The technique developed in this paper relies on the Energy Economic Data Base (EEDB) for baseline estimates of the direct labor hours and/or labor costs required to perform specific tasks in a new construction environment. The labor productivity cost factors adjust for constraining conditions such as working in a radiation environment, poor access, congestion and interference, etc., which typically occur on construction tasks at operating reactors and can occur under certain circumstances at reactors under construction. While the results do not portray all aspects of labor productivity, they encompass the major work place conditions generally discernible by the NRC analysts and assign values that appear to be reasonable within the context of industry experience. 18 refs

  20. Primary length standard adjustment

    Science.gov (United States)

    Ševčík, Robert; Guttenová, Jana

    2007-04-01

    This paper deals with problems and techniques connected with primary length standard adjusting, which includes disassembling of the device and by use of the secondary laser with collimated beam and diffraction laws successively reassembling of the laser. In the reassembling process the device was enhanced with substituting the thermal grease cooling of cold finger by copper socket cooler. This improved external cooling system enables more effective cooling of molecular iodine in the cell, which allows better pressure stability of iodine vapor and easier readjustment of the system.

  1. Statistical methods for transverse beam position diagnostics with higher order modes in third harmonic 3.9 GHz superconducting accelerating cavities at FLASH

    CERN Document Server

    Zhang, P; Jones, R M

    2014-01-01

    Beam-excited higher order modes (HOM) can be used to provide beam diagnostics. Here we focus on 3.9 GHz superconducting accelerating cavities. In particular we study dipole mode excitation and its application to beam position determinations. In order to extract beam position information, linear regression can be used. Due to a large number of sampling points in the waveforms, statistical methods are used to effectively reduce the dimension of the system, such as singular value decomposition (SVD) and k-means clustering. These are compared with the direct linear regression (DLR) on the entire waveforms. A cross-validation technique is used to study the sample independent precisions of the position predictions given by these three methods. A RMS prediction error in the beam position of approximately 50 micron can be achieved by DLR and SVD, while k-means clustering suggests 70 micron.

  2. Beam-transport system for high-resolution heavy-ion spectroscopy

    International Nuclear Information System (INIS)

    Roussel, P.; Kashy, E.

    1980-01-01

    A method is given to adjust a beam-transport system to the requirements of high-energy resolution heavy-ion spectroscopy. The results of a test experiment performed on a MP tandem with a 12 C beam are shown. A drastic improvement in energy resolution is obtained for a kinematical factor K=1/p dp/dtheta=0.12 [fr

  3. Response-only method for damage detection of beam-like structures using high accuracy frequencies with auxiliary mass spatial probing

    Science.gov (United States)

    Zhong, Shuncong; Oyadiji, S. Olutunde; Ding, Kang

    2008-04-01

    This paper proposes a new approach based on auxiliary mass spatial probing using spectral centre correction method (SCCM), to provide a simple solution for damage detection by just using the response time history of beam-like structures. The natural frequencies of a damaged beam with a traversing auxiliary mass change due to change in the inertia of the beam as the auxiliary mass is traversed along the beam, as well as the point-to-point variations in the flexibility of the beam. Therefore the auxiliary mass can enhance the effects of the crack on the dynamics of the beam and, therefore, facilitate the identification and location of damage in the beam. That is, the auxiliary mass can be used to probe the dynamic characteristic of the beam by traversing the mass from one end of the beam to the other. However, it is impossible to obtain accurate modal frequencies by the direct operation of the fast Fourier transform (FFT) of the response data of the structure because the frequency spectrum can be only calculated from limited sampled time data which results in the well-known leakage effect. SCCM is identical to the energy centrobaric correction method (ECCM) which is a practical and effective method used in rotating mechanical fault diagnosis and which resolves the shortcoming of FFT and can provide high accuracy estimate of frequency, amplitude and phase. In the present work, the modal responses of damaged simply supported beams with auxiliary mass are computed using the finite element method (FEM). The graphical plots of the natural frequencies calculated by SCCM versus axial location of auxiliary mass are obtained. However, it is difficult to locate the crack directly from the curve of natural frequencies. A simple and fast method, the derivatives of natural frequency curve, is proposed in the paper which can provide crack information for damage detection of beam-like structures. The efficiency and practicability of the proposed method is illustrated via numerical

  4. DETERMINATION OF STRESS-STRAIN STATE OF A THREE-LAYER BEAM WITH APPLICATION OF CONTACT LAYER METHOD

    Directory of Open Access Journals (Sweden)

    Andreev Vladimir Igorevich

    2016-04-01

    Full Text Available The article deals with the solution for the stress-strain state of a multilayer composite beam with rectangular cross-section, which is bended by normally distributed load. The intermolecular interaction between layers is accomplished by the contact layer, in which the substances of adhesive and substrate are mixed. We consider the contact layer as a transversal anisotropic medium with such parameters that it can be represented as a set of short elastic rods, which are not connected to each other. For simplicity, we assume that the rods are normally oriented to the contact surface. The contact layer method allows us to solve the problem of determining the concentration of tangential stresses arising at the boundaries between the layers and the corner points, their changes, as well as to determine the physical properties of the contact layer basing on experimental data. Resolving the equations obtained in this article can be used for the solution of many problems of the theory of layered substances. These equations were derived from the fundamental laws of the theory of elasticity and generally accepted hypotheses of the theory of plates for the general case of the bending problem of a multilayer beam with any number of layers. The article deals with the example of the numerical solution of the problem of bending of a three-layer beam. On the basis of this solution the curves were obtained, which reflect the stress-strain state of one of the layers. All these curves have a narrow area of the edge effect. The edge effect is associated with a large gradient tangential stresses in the contact layer. The experimental data suggest that in this zone the destruction of the samples occurs. This fact allows us to say that the equations obtained in this article can be used to construct a theory of the strength layered beams under bending.

  5. Single-shot measurements of low emittance beams from laser-plasma accelerators comparing two triggered injection methods

    Science.gov (United States)

    van Tilborg, Jeroen

    2017-10-01

    The success of laser plasma accelerator (LPA) based applications, such as a compact x-ray free electron laser (FEL), relies on the ability to produce electron beams with excellent 6D brightness, where brightness is defined as the ratio of charge to the product of the three normalized emittances. As such, parametric studies of the emittance of LPA generated electron beams are essential. Profiting from a stable and tunable LPA setup, combined with a carefully designed single-shot energy-dispersed emittance diagnostic, we present a direct comparison of charge dependent emittance measurements of electron beams generated by two different injection mechanisms: ionization injection and shock-induced density down-ramp injection. Both injection mechanisms have gained in popularity in recent years due to their demonstrated stable LPA performance. For the down-ramp injection configuration, normalized emittances a factor of two lower were recorded: less than 1 micron at spectral charge densities up to 2 pC/MeV. For both injection mechanisms, a contributing correlation of space charge to the emittance was identified. This measurement technique in general, and these results specifically, are critical to the evaluation of LPA injection methods and development of high-quality LPA beam lines worldwide. This work is supported by the U.S. DOE under Contract No. DE-AC02-05CH11231, by the U.S. DOE NNSA, DNN R&D (NA22), by the National Science Foundation under Grant No. PHY-1415596, and by the Gordon and Betty Moore Foundation under Grant ID GBMF4898.

  6. IA method for measuring the amount of hoar frost formation in the recuperation channels of ventilation systems using the adjustable mathematical model of this process

    Directory of Open Access Journals (Sweden)

    Shilin Aleksandr

    2017-01-01

    Full Text Available The paper presents a method for measuring the amount of hoar frost formation in the recuperation channels of ventilation systems using the adjustable mathematical model of the hoar frost process. The principle is based on the fact that the contour of the adjustment of the hoar frost model is included in the measurement in accordance with the measured pressure drop, which is proportional to the amount of hoar frost. Unlike the known measurement methods, it is proposed to use the state variables of the mathematical model as the measured value. These state variables are not subject to non-deterministic interferences and random influences. The paper presents simulation results confirming the adequacy of the dynamic model. In conclusion, an example of the use of a recuperation channel in the defrost management system is given.

  7. On the feasibility of the Chevron Notch Beam method to measure fracture toughness of fine-grained zirconia ceramics.

    Science.gov (United States)

    Kailer, Andreas; Stephan, Marc

    2016-10-01

    The fracture toughness determination of fine-grained zirconia ceramics using the chevron notched beam method (CNB) was investigated to assess the feasibility of this method for quality assurance and material characterization. CNB tests were performed using four different yttria-stabilized zirconia ceramics under various testing modes and conditions, including displacement-controlled and load-rate-controlled four point bending to assess the influence of slow crack growth and identify most suitable test parameters. For comparison, tests using single-edge V-notch beams (SEVNB) were conducted. It was observed that the CNB method yields well-reproducible results. However, slow crack growth effects significantly affect the measured KIC values, especially when slow loading rates are used. To minimize the effect of slow crack growth, the application of high loading rates is recommended. Despite a certain effort needed for setting up a sample preparation routine, the CNB method is considered to be very useful for measuring and controlling the fracture toughness of zirconia ceramics. Copyright © 2016 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  8. Analysis of residual stresses on the transverse beam of a casting stand by means of drilling method

    Directory of Open Access Journals (Sweden)

    P. Frankovský

    2014-10-01

    Full Text Available The presented paper demonstrates the application of drilling method in the analysis of residual stresses on the transverse beam of a casting stand. In the initial stage of the analysis the determination of strains was done for individual steps of drilling in the area which was determined by means of numerical analysis. The drilling was carried out gradually by 0,5 mm up to the depth of 5 mm, while the diameter of the drilled hole was 3,2 mm. During the analysis we used the drilling device RS-200, strain indicator P3 and SGD 1-RY21-3/120. The paper presents the development of residual stresses throughout the depth of the drilled hole which were determined according to standard ASTM E837-01, by means of integral method, power series method and by means of Power Series method.

  9. Effective X-ray beam size measurements of an X-ray tube and polycapillary X-ray lens system using a scanning X-ray fluorescence method

    Energy Technology Data Exchange (ETDEWEB)

    Gherase, Mihai R., E-mail: mgherase@csufresno.edu; Vargas, Andres Felipe

    2017-03-15

    Size measurements of an X-ray beam produced by an integrated polycapillary X-ray lens (PXL) and X-ray tube system were performed by means of a scanning X-ray fluorescence (SXRF) method using three different metallic wires. The beam size was obtained by fitting the SXRF data with the analytical convolution between a Gaussian and a constant functions. For each chemical element in the wire an effective energy was calculated based on the incident X-ray spectrum and its photoelectric cross section. The proposed method can be used to measure the effective X-ray beam size in XRF microscopy studies.

  10. Experimental methods in radioactive ion-beam target/ion source development and characterization

    International Nuclear Information System (INIS)

    Welton, R.F.; Alton, G.D.; Cui, B.; Murray, S.N.

    1998-01-01

    We have developed off-line experimental techniques and apparatuses that permit direct measurement of effusive-flow delay times and ionization efficiencies for nearly any chemically reactive element in high-temperature target/ion sources (TIS) commonly used for on-line radioactive ion-beam (RIB) generation. The apparatuses include a hot Ta valve for effusive-flow delay-time measurements, a cooled molecular injection system for determination of ionization efficiencies, and a gas flow measurement/control system for introducing very low, well-defined molecular flows into the TIS. Measurements are performed on a test stand using molecular feed compounds containing stable complements of the radioactive nuclei of interest delivered to the TIS at flow rates commensurate with on-line RIB generation. In this article, the general techniques are described and effusive-flow delay times and ionization efficiency measurements are reported for fluorine in an electron-beam plasma target/ion source developed for RIB generation and operated in both positive- and negative-ion extraction modes. copyright 1998 American Institute of Physics

  11. A beam energy measurement system at NIRS-930 cyclotron

    International Nuclear Information System (INIS)

    Hojo, S.; Honma, T.; Sakamoto, Y.; Miyahara, N.; Okada, T.; Komatsu, K.; Tsuji, N.; Yamada, S.

    2005-01-01

    A beam energy measurement system employing a set of capacitive probes has been developed at NIRS-930 cyclotron. Principle of the measurement is applying a modified-TOF method, so that the two proves are installed at one of the straight section in the beam transport line. Usually they are separated about 5.8 m, which is equivalent to the almost final path length of the beam extracted in the cyclotron. In the measurement, two beam signals are superimposed by adjusting a position of the downstream-probe along the beam direction with watching an oscilloscope screen roughly. In order to determine the beam energy accurately the signals are processed by MCA with suitable electric module. (author)

  12. Adjustment of a direct method for the determination of man body burden in Pu-239 on by X-ray detection of U-235

    International Nuclear Information System (INIS)

    Boulay, P.

    1968-04-01

    The use of Pu-239 on a larger scale sets a problem about the contamination measurement by aerosol at lung level. A method of direct measurement of Pu-239 lung burden is possible, thanks to the use of a large area window proportional counter. A counter of such pattern, has been especially carried out for this purpose. The adjustment of the apparatus allows an adequate sensibility to detect a contamination at the maximum permissible body burden level. Besides, a method for individual 'internal calibration', with a plutonium mock: the protactinium-233, is reported. (author) [fr

  13. On the accuracy of homotopy perturbation and variational iteration methods for lateral broadening of a monoenergetic proton beam

    Energy Technology Data Exchange (ETDEWEB)

    Noshad, Houshyar, E-mail: hnoshad@aut.ac.ir [Department of Energy Engineering and Physics, Amirkabir University of Technology (Tehran Polytechnic), P.O. Box 15875-4413, Hafez Avenue, Tehran (Iran, Islamic Republic of); Bahador, Seyyedeh Samira; Mohammadi, Saeed [Department of Physics, Payame Noor University, P.O. BOX 19395-3697, Tehran (Iran, Islamic Republic of)

    2013-10-01

    In this article, dispersion of a 60 MeV proton pencil beam at various depths in a muscle tissue was numerically investigated via solving a three dimensional Fokker–Planck equation using homotopy perturbation method (HPM) and variational iteration method (VIM). The accuracy of these methods was benchmarked by comparison the radial flux distribution of protons traversing different depths in the tissue with the data of the High Charge and Energy Transport (HZETRN) model and Monte Carlo simulations. Furthermore, the computed depth dose distributions obtained from the HPM and VIM for monoenergetic protons passing through a medium were compared with the results of GEANT4.5.2 code as well as the experimental data reported in the literature. The satisfactory agreement obtained from our computations shows the reliability and applicability of the HPM and VIM in our analysis.

  14. Methods for assisting recovery of damaged brain and spinal cord and treating various diseases using arrays of x-ray microplanar beams

    Energy Technology Data Exchange (ETDEWEB)

    Dilmanian, F Avraham [Yaphank, NY; Anchel, David J [Rocky Point, NY; Gaudette, Glenn [Holden, MA; Romanelli, Pantaleo [Monteroduni, IT; Hainfeld, James [Shoreham, NY

    2010-06-29

    A method of assisting recovery of an injury site of the central nervous system (CNS) or treating a disease includes providing a therapeutic dose of X-ray radiation to a target volume through an array of parallel microplanar beams. The dose to treat CNS injury temporarily removes regeneration inhibitors from the irradiated site. Substantially unirradiated cells surviving between beams migrate to the in-beam portion and assist recovery. The dose may be staggered in fractions over sessions using angle-variable intersecting microbeam arrays (AVIMA). Additional doses are administered by varying the orientation of the beams. The method is enhanced by injecting stem cells into the injury site. One array or the AVIMA method is applied to ablate selected cells in a target volume associated with disease for palliative or curative effect. Atrial fibrillation is treated by irradiating the atrial wall to destroy myocardial cells while continuously rotating the subject.

  15. Evaluation of 6 and 8 MeV clinical electron beams for NEPTUN 10PC linear accelerator using Monte Carlo Method

    International Nuclear Information System (INIS)

    Jabbari, N.; Hashemi Malayeri, B.; Farajollahi, A.; Kazemnejad, A.; Shafaei, A.; Jabbari, Sh.

    2007-01-01

    Electron beams are widely used in radiation therapy. Since the nominal electron energy value is not quite meaningful for physics or dosimetry purposes in treatment planning, depth dose data for electron beams must be determined and used. The purpose of this study was to obtain the depth dose data for the 6 and 8 MeV electron beams of a NEPTUN 10PC linac and evaluating its beam characteristics using Monte Carlo method. The linac electron beams were modeled using the BEAMnrc code. The DOSXYZnrc code was also used for the simulation of RFA 300 water phantom. The central axis depth dose and the beam profiles were calculated for the beam energies at the 10 x 10 cm 2 field size. The R 1 00, R q , R 8 5, R 5 0 and R p , parameters were extracted from the normalized depth-dose curves. The calculated results were compared with the experimental data, where the agreement between them was very good. Since different linacs from the same manufacturer and model usually have the same structures, it seems that it can be possible to model different linacs based on a particular one from the same manufacturer by defining their energy spectra and the beam quality indexes. In addition, using this method enables us to assess the characteristics of the electron beam at the exit of the linac and the effects of every part of the linacs head structure on the electron beams. It may also be possible to study and evaluate the final dose distribution

  16. Reliability of engineering methods of assessment the critical buckling load of steel beams

    Science.gov (United States)

    Rzeszut, Katarzyna; Folta, Wiktor; Garstecki, Andrzej

    2018-01-01

    In this paper the reliability assessment of buckling resistance of steel beam is presented. A number of parameters such as: the boundary conditions, the section height to width ratio, the thickness and the span are considered. The examples are solved using FEM procedures and formulas proposed in the literature and standards. In the case of the numerical models the following parameters are investigated: support conditions, mesh size, load conditions, steel grade. The numerical results are compared with approximate solutions calculated according to the standard formulas. It was observed that for high slenderness section the deformation of the cross-section had to be described by the following modes: longitudinal and transverse displacement, warping, rotation and distortion of the cross section shape. In this case we face interactive buckling problem. Unfortunately, neither the EN Standards nor the subject literature give close-form formulas to solve these problems. For this reason the reliability of the critical bending moment calculations is discussed.

  17. Comparison between different methods of magnetic field diagnostics in beam emission spectroscopy

    International Nuclear Information System (INIS)

    Voslamber, D.

    1995-01-01

    Magnetic field diagnostics in tokamaks using the motional Stark effect in fast neutral beams have been based on two kinds of polarimetry which are called 'static' and 'dynamic'. It is shown that static polarimetry presents a number of advantages over dynamic polarimetry, provided it is made complete in the sense that a sufficient number of polarisation analysers is installed and different parts of the spectrum are explored to yield full information on the set of unknowns inherent in the problem. A detailed scheme of self-calibrating static polarimetry is proposed, including the case where an in-vessel mirror with changing characteristics (coating by impurities) is placed in front of the optical detection system. (author) 5 refs.; 2 figs

  18. Accuracy and Reliability of a Novel Method for Fusion of Digital Dental Casts and Cone Beam Computed Tomography Scans

    Science.gov (United States)

    Rangel, Frits A.; Maal, Thomas J. J.; Bronkhorst, Ewald M.; Breuning, K. Hero; Schols, Jan G. J. H.; Bergé, Stefaan J.; Kuijpers-Jagtman, Anne Marie

    2013-01-01

    Several methods have been proposed to integrate digital models into Cone Beam Computed Tomography scans. Since all these methods have some drawbacks such as radiation exposure, soft tissue deformation and time-consuming digital handling processes, we propose a new method to integrate digital dental casts into Cone Beam Computed Tomography scans. Plaster casts of 10 patients were randomly selected and 5 titanium markers were glued to the upper and lower plaster cast. The plaster models were scanned, impressions were taken from the plaster models and the impressions were also scanned. Linear measurements were performed on all three models, to assess accuracy and reproducibility. Besides that, matching of the scanned plaster models and scanned impressions was done, to assess the accuracy of the matching procedure. Results show that all measurement errors are smaller than 0.2 mm, and that 81% is smaller than 0.1 mm. Matching of the scanned plaster casts and scanned impressions show a mean error between the two surfaces of the upper arch of 0.14 mm and for the lower arch of 0.18 mm. The time needed for reconstructing the CBCT scans to a digital patient, where the impressions are integrated into the CBCT scan of the patient takes about 15 minutes, with little variance between patients. In conclusion, we can state that this new method is a reliable method to integrate digital dental casts into CBCT scans. As far as radiation exposure, soft tissue deformation and digital handling processes are concerned, it is a significant improvement compared to the previously published methods. PMID:23527111

  19. Electron beam control for barely separated beams

    Energy Technology Data Exchange (ETDEWEB)

    Douglas, David R.; Ament, Lucas J. P.

    2017-04-18

    A method for achieving independent control of multiple beams in close proximity to one another, such as in a multi-pass accelerator where coaxial beams are at different energies, but moving on a common axis, and need to be split into spatially separated beams for efficient recirculation transport. The method for independent control includes placing a magnet arrangement in the path of the barely separated beams with the magnet arrangement including at least two multipole magnets spaced closely together and having a multipole distribution including at least one odd multipole and one even multipole. The magnetic fields are then tuned to cancel out for a first of the barely separated beams to allow independent control of the second beam with common magnets. The magnetic fields may be tuned to cancel out either the dipole component or tuned to cancel out the quadrupole component in order to independently control the separate beams.

  20. Beam Techniques - Beam Control and Manipulation

    Energy Technology Data Exchange (ETDEWEB)

    Minty, Michiko G

    2003-04-24

    We describe commonly used strategies for the control of charged particle beams and the manipulation of their properties. Emphasis is placed on relativistic beams in linear accelerators and storage rings. After a brief review of linear optics, we discuss basic and advanced beam control techniques, such as transverse and longitudinal lattice diagnostics, matching, orbit correction and steering, beam-based alignment, and linac emittance preservation. A variety of methods for the manipulation of particle beam properties are also presented, for instance, bunch length and energy compression, bunch rotation, changes to the damping partition number, and beam collimation. The different procedures are illustrated by examples from various accelerators. Special topics include injection and extraction methods, beam cooling, spin transport and polarization.

  1. Methods and approaches to provide feedback from nuclear and covariance data adjustment for improvement of nuclear data files. SG39 meeting, May 2016

    International Nuclear Information System (INIS)

    Herman, Michal Wladyslaw; Cabellos De Francisco, Oscar; Beck, Bret; Ignatyuk, Anatoly V.; Palmiotti, Giuseppe; Grudzevich, Oleg T.; Salvatores, Massimo; Chadwick, Mark; Pelloni, Sandro; Diez De La Obra, Carlos Javier; Wu, Haicheng; Sobes, Vladimir; Rearden, Bradley T.; Yokoyama, Kenji; Hursin, Mathieu; Penttila, Heikki; Kodeli, Ivan-Alexander; Plevnik, Lucijan; Plompen, Arjan; Gabrielli, Fabrizio; Leal, Luiz Carlos; Aufiero, Manuele; Fiorito, Luca; Hummel, Andrew; Siefman, Daniel; Leconte, Pierre

    2016-05-01

    The aim of WPEC subgroup 39 'Methods and approaches to provide feedback from nuclear and covariance data adjustment for improvement of nuclear data files' is to provide criteria and practical approaches to use effectively the results of sensitivity analyses and cross section adjustments for feedback to evaluators and differential measurement experimentalists in order to improve the knowledge of neutron cross sections, uncertainties, and correlations to be used in a wide range of applications. WPEC subgroup 40-CIELO (Collaborative International Evaluated Library Organization) provides a new working paradigm to facilitate evaluated nuclear reaction data advances. It brings together experts from across the international nuclear reaction data community to identify and document discrepancies among existing evaluated data libraries, measured data, and model calculation interpretations, and aims to make progress in reconciling these discrepancies to create more accurate ENDF-formatted files. SG40-CIELO focusses on 6 important isotopes: 1 H, 16 O, 56 Fe, 235,238 U, 239 Pu. This document is the proceedings of the seventh formal Subgroup 39 meeting and of the Joint SG39+SG40 Session held at the NEA, OECD Conference Center, Paris, France on 10-11 May 2016. It comprises a Summary Record of the meeting, and all the available presentations (slides) given by the participants: A - Welcome and actions review (Oscar CABELLOS); B - Methods: - XGPT: uncertainty propagation and data assimilation from continuous energy covariance matrix and resonance parameters covariances (Manuele AUFIERO); - Optimal experiment utilization (REWINDing PIA), (G. Palmiotti); C - Experiment analysis, sensitivity calculations and benchmarks: - Tripoli-4 analysis of SEG experiments (Andrew HUMMEL); - Tripoli-4 analysis of BERENICE experiments (P. DUFAY, Cyrille DE SAINT JEAN); - Preparation of sensitivities of k-eff, beta-eff and shielding benchmarks for adjustment exercise (Ivo KODELI); - SA and

  2. Study of different registration methods for on-line kilovoltage cone-beam CT guided lung cancer radiation

    International Nuclear Information System (INIS)

    Wang Yanyang; Fu Xiaolong; Xia Bing; Wu Zhengqin; Fan Min; Yang Huanjun; Xu Zhiyong; Jiang Guoliang

    2009-01-01

    Objective: To select the optimal registration method for on-line kilovoltage cone-beam CT (KVCBCT) guided lung cancer radiation and evaluate the reproducibility of the selected method. Methods: Sixteen patients with non-small cell lung cancer were enrolled into this study. A total of 96 pretreatment KVCBCT images from the 16 patients were available for the analysis. Image registration methods were bone-based automatic registration, gray-based automatic registration, manual registration and semi-automatic registration. All registrations were accomplished by one physician. Another physician blindly evaluated the results of each registration, then selected the optimal registration method and evaluated its reproducibility. Results: The average score of the bone-based automatic registration, gray-based automatic registration, manual registration and semi-automatic registration methods was 2.4, 2.7, 3.0 and 3.7, respectively. The score of the four different groups had statistics significant difference (F=42.20, P<0.001). Using the semi-automatic registration method, the probability of the difference between two registration results more than 3 mm in the left-right, superior-inferior, and anterior-posterior directions was 0, 3% and 6% by the same physician, 0, 14% and 0 by different physicians, and 8%, 14% and 8% by physician and radiation therapist. Conclusions: Semi-automatic registration method, possessing the highest score and accepted reproducibility, is appropriate for KVCBCT guided lung cancer radiation. (authors)

  3. The $1^{+}\\to n^{+}$ charge breeding method for the production of radioactive and stable continuous /pulsed multi-chargedion beams

    CERN Document Server

    Chauvin, N; Bouly, J L; Curdy, Jean Claude; Geller, R; Lamy, T; Solé, P; Sortais, P

    1999-01-01

    The principle of the 1+ -> n+ charge breeding method by injecting a mono-charged ion beam in an Electron Cyclotron Resonance Ion Source is recalled. Some 1+ ->n+ breeding efficiencies in continuous mode are given, like 9% for Ar1+ ->Ar8+ and 5% for Rb1+->Rb15+. The global capture efficiency is deduced from the whole charge state distribution spectrum. The ECRIT (ECR Ion Trap) mode that allows to produce a pulsed multi-charged beam is explained. The n+ ions are extracted in a 20 ms pulse. The breeding-bunching efficiencies are measured for Rb1+->Rb15+ (2.2%) and Pb1+->Pb22+ (1.3 %). Ion trapping time in the ECRIT plasma is evaluated to some hundreds of ms. A new application of the 1+->n+ method is developed: the production of multi-charged natural metallic ions. First experiments have been done on uranium: a 500 nA continuous current of U26+ has been measured. Finally, the future developments on the 1+->n+ experiment are discussed. A description of a 1+ ->n+ dedicated high performance ECRIS named PHOENIX (Prod...

  4. A proposed method for accurate 3D analysis of cochlear implant migration using fusion of cone beam CT

    Directory of Open Access Journals (Sweden)

    Guido eDees

    2016-01-01

    Full Text Available IntroductionThe goal of this investigation was to compare fusion of sequential cone beam CT volumes to the gold standard (fiducial registration in order to be able to analyze clinical CI migration with high accuracy in three dimensions. Materials and MethodsPaired time-lapsed cone beam CT volumes were performed on five human cadaver temporal bones and one human subject. These volumes were fused using 3D Slicer 4 and BRAINSFit software. Using a gold standard fiducial technique, the accuracy, robustness and performance time of the fusion process were assessed.Results This proposed fusion protocol achieves a sub voxel mean Euclidean distance of 0.05 millimeter in human cadaver temporal bones and 0.16 millimeter when applied to the described in vivo human synthetic data set in over 95% of all fusions. Performance times are less than two minutes.ConclusionHere a new and validated method based on existing techniques is described which could be used to accurately quantify migration of cochlear implant electrodes.

  5. Methods and approaches to provide feedback from nuclear and covariance data adjustment for improvement of nuclear data files. SG39 meeting, November 2014

    International Nuclear Information System (INIS)

    Aufiero, Manuele; Ivanov, Evgeny; Hoefer, Axel; Yokoyama, Kenji; Da Cruz, Dirceu Ferreira; KODELI, Ivan-Alexander; Hursin, Mathieu; Pelloni, Sandro; Palmiotti, Giuseppe; Salvatores, Massimo; Barnes, Andrew; Cabellos De Francisco, Oscar; ); Ivanova, Tatiana; )

    2014-11-01

    The aim of WPEC subgroup 39 'Methods and approaches to provide feedback from nuclear and covariance data adjustment for improvement of nuclear data files' is to provide criteria and practical approaches to use effectively the results of sensitivity analyses and cross section adjustments for feedback to evaluators and differential measurement experimentalists in order to improve the knowledge of neutron cross sections, uncertainties, and correlations to be used in a wide range of applications. This document is the proceedings of the third formal Subgroup meeting held at the NEA, Issy-les-Moulineaux, France, on 27-28 November 2014. It comprises a Summary Record of the meeting and all the available presentations (slides) given by the participants: A - Sensitivity methods: 1 - Perturbation/sensitivity calculations with Serpent (M. Aufiero); 2 - Comparison of deterministic and Monte Carlo sensitivity analysis of SNEAK-7A and FLATTOP-Pu Benchmarks (I. Kodeli); B - Integral experiments: 1 - PROTEUS experiments: selected experiments sensitivity profiles and availability, (M. Hursin, M. Salvatores - PROTEUS Experiments, HCLWR configurations); 2 - SINBAD Benchmark Database and FNS/JAEA Liquid Oxygen TOF Experiment Analysis (I. Kodeli); 3 - STEK experiment Opportunity for Validation of Fission Products Nuclear Data (D. Da Cruz); 4 - SEG (tailored adjoint flux shapes) (M. Savatores - comments) 5 - IPPE transmission experiments (Fe, 238 U) (T. Ivanova); 6 - RPI semi-integral (Fe, 238 U) (G. Palmiotti - comments); 7 - New experiments, e.g. in connection with the new NSC Expert Group on 'Improvement of Integral Experiments Data for Minor Actinide Management' (G. Palmiotti - Some comments from the Expert Group) 8 - Additional PSI adjustment studies accounting for nonlinearity (S. Pelloni); 9 - Adjustment methodology issues (G. Palmiotti); C - Am-241 and fission product issues: 1 - Am-241 validation for criticality-safety calculations (A. Barnes - Visio

  6. The digital structural analysis of cadmium selenide crystals by a method of ion beam thinning for high resolution electron microscopy

    International Nuclear Information System (INIS)

    Kanaya, Koichi; Baba, Norio; Naka, Michiaki; Kitagawa, Yukihisa; Suzuki, Kunio

    1986-01-01

    A digital processing method using a scanning densitometer system for structural analysis of electron micrographs was successfully applied to a study of cadmium selenide crystals, which were prepared by an argon-ion beam thinning method. Based on Fourier techniques for structural analysis from a computer-generated diffractogram, it was demonstrated that when cadmium selenide crystals were sufficiently thin to display the higher order diffraction spots at a high resolution approaching the atomic level, they constitute an alternative hexagonal lattice of imperfect wurtzite phase from a superposition of individual harmonic images by the enhanced scattering amplitude and corrected phase. From the structural analysis data, a Fourier synthetic lattice image was reconstructed, representing the precise location and three-dimensional arrangement of each of the atoms in the unit cell. Extensively enhanced lattice defect images of dislocations and stacking faults were also derived and shown graphically. (author)

  7. Ion beam analysis - development and application of nuclear reaction analysis methods, in particular at a nuclear microprobe

    International Nuclear Information System (INIS)

    Sjoeland, K.A.

    1996-11-01

    This thesis treats the development of Ion Beam Analysis methods, principally for the analysis of light elements at a nuclear microprobe. The light elements in this context are defined as having an atomic number less than approx. 13. The work reported is to a large extent based on multiparameter methods. Several signals are recorded simultaneously, and the data can be effectively analyzed to reveal structures that can not be observed through one-parameter collection. The different techniques are combined in a new set-up at the Lund Nuclear Microprobe. The various detectors for reaction products are arranged in such a way that they can be used for the simultaneous analysis of hydrogen, lithium, boron and fluorine together with traditional PIXE analysis and Scanning Transmission Ion Microscopy as well as photon-tagged Nuclear Reaction Analysis. 48 refs

  8. Ion beam analysis - development and application of nuclear reaction analysis methods, in particular at a nuclear microprobe

    Energy Technology Data Exchange (ETDEWEB)

    Sjoeland, K.A.

    1996-11-01

    This thesis treats the development of Ion Beam Analysis methods, principally for the analysis of light elements at a nuclear microprobe. The light elements in this context are defined as having an atomic number less than approx. 13. The work reported is to a large extent based on multiparameter methods. Several signals are recorded simultaneously, and the data can be effectively analyzed to reveal structures that can not be observed through one-parameter collection. The different techniques are combined in a new set-up at the Lund Nuclear Microprobe. The various detectors for reaction products are arranged in such a way that they can be used for the simultaneous analysis of hydrogen, lithium, boron and fluorine together with traditional PIXE analysis and Scanning Transmission Ion Microscopy as well as photon-tagged Nuclear Reaction Analysis. 48 refs.

  9. A line fiducial method for geometric calibration of cone-beam CT systems with diverse scan trajectories

    Science.gov (United States)

    Jacobson, M. W.; Ketcha, M. D.; Capostagno, S.; Martin, A.; Uneri, A.; Goerres, J.; De Silva, T.; Reaungamornrat, S.; Han, R.; Manbachi, A.; Stayman, J. W.; Vogt, S.; Kleinszig, G.; Siewerdsen, J. H.

    2018-01-01

    Modern cone-beam CT systems, especially C-arms, are capable of diverse source-detector orbits. However, geometric calibration of these systems using conventional configurations of spherical fiducials (BBs) may be challenged for novel source-detector orbits and system geometries. In part, this is because the BB configurations are designed with careful forethought regarding the intended orbit so that BB marker projections do not overlap in projection views. Examples include helical arrangements of BBs (Rougee et al 1993 Proc. SPIE 1897 161-9) such that markers do not overlap in projections acquired from a circular orbit and circular arrangements of BBs (Cho et al 2005 Med. Phys. 32 968-83). As a more general alternative, this work proposes a calibration method based on an array of line-shaped, radio-opaque wire segments. With this method, geometric parameter estimation is accomplished by relating the 3D line equations representing the wires to the 2D line equations of their projections. The use of line fiducials simplifies many challenges with fiducial recognition and extraction in an orbit-independent manner. For example, their projections can overlap only mildly, for any gantry pose, as long as the wires are mutually non-coplanar in 3D. The method was tested in application to circular and non-circular trajectories in simulation and in real orbits executed using a mobile C-arm prototype for cone-beam CT. Results indicated high calibration accuracy, as measured by forward and backprojection/triangulation error metrics. Triangulation errors on the order of microns and backprojected ray deviations uniformly less than 0.2 mm were observed in both real and simulated orbits. Mean forward projection errors less than 0.1 mm were observed in a comprehensive sweep of different C-arm gantry angulations. Finally, successful integration of the method into a CT imaging chain was demonstrated in head phantom scans.

  10. Strength on cut edge and ground edge glass beams with the failure analysis method

    Directory of Open Access Journals (Sweden)

    Stefano Agnetti

    2013-10-01

    Full Text Available The aim of this work is the study of the effect of the finishing of the edge of glass when it has a structural function. Experimental investigations carried out for glass specimens are presented. Various series of annealed glass beam were tested, with cut edge and with ground edge. The glass specimens are tested in four-point bending performing flaw detection on the tested specimens after failure, in order to determine glass strength. As a result, bending strength values are obtained for each specimen. Determining some physical parameter as the depth of the flaw and the mirror radius of the fracture, after the failure of a glass element, it could be possible to calculate the failure strength of that.The experimental results were analyzed with the LEFM theory and the glass strength was analyzed with a statistical study using two-parameter Weibull distribution fitting quite well the failure stress data. The results obtained constitute a validation of the theoretical models and show the influence of the edge processing on the failure strength of the glass. Furthermore, series with different sizes were tested in order to evaluate the size effect.

  11. Method to measure composition modifications in polyethylene terephthalate during ion beam irradiation

    Science.gov (United States)

    Abdesselam, M.; Stoquert, J. P.; Chami, S.; Djebara, M.; Chami, A. C.; Siad, M.

    2009-01-01

    Matter losses of polyethylene terephthalate (PET, Mylar) films induced by 1600 keV deuteron beams have been investigated in situ simultaneously by nuclear reaction analysis (NRA), deuteron forward elastic scattering (DFES) and hydrogen elastic recoil detection (HERD) in the fluence range from 1 × 10 14 to 9 × 10 16 cm -2. Volatile degradation products escape from the polymeric film, mostly as hydrogen-, oxygen- and carbon-containing molecules. Appropriate experimental conditions for observing the composition and thickness changes during irradiation are determined. 16O(d,p 0) 17O, 16O(d,p 1) 17O and 12C(d,p 0) 13C nuclear reactions were used to monitor the oxygen and carbon content as a function of deuteron fluence. Hydrogen release was determined simultaneously by H(d,d)H DFES and H(d,H)d HERD. Comparisons between NRA, DFES and HERD measurements show that the polymer carbonizes at high fluences because most of the oxygen and hydrogen depletion has already occured below a fluence of 3 × 10 16 cm -2. Release curves for each element are determined. Experimental results are consistent with the bulk molecular recombination (BMR) model.

  12. Evaluation of a method for correction of scatter radiation in thorax cone beam CT; Evaluation d'une methode de correction du rayonnement diffuse en tomographie du thorax avec faisceau conique

    Energy Technology Data Exchange (ETDEWEB)

    Rinkel, J.; Dinten, J.M. [CEA Grenoble (DTBS/STD), Lab. d' Electronique et de Technologie de l' Informatique, LETI, 38 (France); Esteve, F. [European Synchrotron Radiation Facility (ESRF), 38 - Grenoble (France)

    2004-07-01

    Purpose: Cone beam CT (CBCT) enables three-dimensional imaging with isotropic resolution. X-ray scatter estimation is a big challenge for quantitative CBCT imaging of thorax: scatter level is significantly higher on cone beam systems compared to collimated fan beam systems. The effects of this scattered radiation are cupping artefacts, streaks, and quantification inaccuracies. The beam stops conventional scatter estimation approach can be used for CBCT but leads to a significant increase in terms of dose and acquisition time. At CEA-LETI has been developed an original scatter management process without supplementary acquisition. Methods and Materials: This Analytical Plus Indexing-based method (API) of scatter correction in CBCT is based on scatter calibration through offline acquisitions with beam stops on lucite plates, combined to an analytical transformation issued from physical equations. This approach has been applied with success in bone densitometry and mammography. To evaluate this method in CBCT, acquisitions from a thorax phantom with and without beam stops have been performed. To compare different scatter correction approaches, Feldkamp algorithm has been applied on rough data corrected from scatter by API and by beam stops approaches. Results: The API method provides results in good agreement with the beam stops array approach, suppressing cupping artefact. Otherwise influence of the scatter correction method on the noise in the reconstructed images has been evaluated. Conclusion: The results indicate that the API method is effective for quantitative CBCT imaging of thorax. Compared to a beam stops array method it needs a lower x-ray dose and shortens acquisition time. (authors)

  13. Methods and approaches to provide feedback from nuclear and covariance data adjustment for improvement of nuclear data files. SG39 meeting, May 2015

    International Nuclear Information System (INIS)

    Wang, Wenming; Yokoyama, Kenji; Kim, Do Heon; Kodeli, Ivan-Alexander; Hursin, Mathieu; Pelloni, Sandro; Palmiotti, Giuseppe; Salvatores, Massimo; Touran, Nicholas; Cabellos De Francisco, Oscar; )

    2015-05-01

    The aim of WPEC subgroup 39 'Methods and approaches to provide feedback from nuclear and covariance data adjustment for improvement of nuclear data files' is to provide criteria and practical approaches to use effectively the results of sensitivity analyses and cross section adjustments for feedback to evaluators and differential measurement experimentalists in order to improve the knowledge of neutron cross sections, uncertainties, and correlations to be used in a wide range of applications. This document is the proceedings of the fourth Subgroup meeting, held at the NEA, Issy-les-Moulineaux, France, on 19-20 May 2015. It comprises a Summary Record of the meeting, two papers on deliverables and all the available presentations (slides) given by the participants: 1 - Status of Deliverables: '1. Methodology' (K. Yokoyama); 2 - Status of Deliverables: '2. Comments on covariance data' (K. Yokoyama); 3 - PROTEUS HCLWR Experiments (M. Hursin); 4 - Preliminary UQ Efforts for TWR Design (N. Touran); 5 - Potential use of beta-eff and other benchmark for adjustment (I. Kodeli); 6 - k eff uncertainties for a simple case of Am 241 using different codes and evaluated files (I. Kodeli); 7 - k eff uncertainties for a simple case of Am 241 using TSUNAMI (O. Cabellos); 8 - REWIND: Ranking Experiments by Weighting to Improve Nuclear Data (G. Palmiotti); 9 - Recent analysis on NUDUNA/MOCABA applications to reactor physics parameters (E. Castro); 10 - INL exploratory study for SEG (A. Hummel); 11 - The Development of Nuclear Data Adjustment Code at CNDC (H. Wu); 12 - SG39 Perspectives (M. Salvatores). A list of issues and actions conclude the document

  14. Estimating the biomass of unevenly distributed aquatic vegetation in a lake using the normalized water-adjusted vegetation index and scale transformation method.

    Science.gov (United States)

    Gao, Yongnian; Gao, Junfeng; Wang, Jing; Wang, Shuangshuang; Li, Qin; Zhai, Shuhua; Zhou, Ya

    2017-12-01

    Satellite remote sensing is advantageous for the mapping and monitoring of aquatic vegetation biomass at large spatial scales. We proposed a scale transformation (CT) method of converting the field sampling-site biomass from the quadrat to pixel scale and a new normalized water-adjusted vegetation index (NWAVI) based on remotely sensed imagery for the biomass estimation of aquatic vegetation (excluding emergent vegetation). We used a modeling approach based on the proposed CT method and NWAVI as well as statistical analyses including linear, quadratic, logarithmic, cubic, exponential, inverse and power regression to estimate the aquatic vegetation biomass, and we evaluated the performance of the biomass estimation. We mapped the spatial distribution and temporal change of the aquatic vegetation biomass using a geographic information system in a test lake in different months. The exponential regression models based on CT and the NWAVI had optimal adjusted R 2 , F and Sig. values in both May and August 2013. The scatter plots of the observed versus the predicted biomass showed that most of the validated field sites were near the 1:1 line. The RMSE, ARE and RE values were small. The spatial distribution and change of the aquatic vegetation biomass in the study area showed clear variability. Among the NWAVI-based and other vegetation index-based models, the CT and NWAVI-based models had the largest adjusted R 2 , F and the smallest ARE values in both tests. The proposed modeling scheme is effective for the biomass estimation of aquatic vegetation in lakes. It indicated that the proposed method can provide a most accurate spatial distribution map of aquatic vegetation biomass for lake ecological management. More accurate biomass maps of aquatic vegetation are essential for implementing conservation policy and for reducing uncertainties in our understanding of the lake carbon cycle. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Comparison of a new laser beam wound camera and a digital photoplanimetry-based method for wound measurement in horses.

    Science.gov (United States)

    Van Hecke, L L; De Mil, T A; Haspeslagh, M; Chiers, K; Martens, A M

    2015-03-01

    The aim of this study was to compare the accuracy, precision, inter- and intra-operator reliability of a new laser beam (LB) wound camera and a digital photoplanimetry-based (DPB) method for measuring the dimensions of equine wounds. Forty-one wounds were created on equine cadavers. The area, circumference, maximum depth and volume of each wound were measured four times with both techniques by two operators. A silicone cast was made of each wound and served as the reference standard to measure the wound dimensions. The DPB method had a higher accuracy and precision in determining the wound volume compared with the LB camera, which had a higher accuracy in determining the wound area and maximum depth and better precision in determining the area and circumference. The LB camera also had a significantly higher overall inter-operator reliability for measuring the wound area, circumference and volume. In contrast, the DPB method had poor intra-operator reliability for the wound circumference. The LB camera was more user-friendly than the DPB method. The LB wound camera is recommended as the better objective method to assess the dimensions of wounds in horses, despite its poorer performance for the measurement of wound volume. However, if the wound measurements are performed by one operator on cadavers or animals under general anaesthesia, the DPB method is a less expensive and valid alternative. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Double-beam optical method and apparatus for measuring thermal diffusivity and other molecular dynamic processes in utilizing the transient thermal lens effect

    International Nuclear Information System (INIS)

    Gupta, A.; Hong, S.; Moacanin, J.

    1981-01-01

    A method and apparatus for measuring thermal diffusivity and molecular relaxation processes in a sample material utilizing two light beams, one being a pulsed laser light beam for forming a thermal lens in the sample material, and the other being a relatively low power probe light beam for measuring changes in the refractive index of the sample material during formation and dissipation of the thermal lens. More specifically, a sample material is irradiated by relatively high power, short pulses from a dye laser. Energy from the pulses is absorbed by the sample material, thereby forming a thermal lens in the area of absorption. The pulse repetition rate is chosen so that the thermal lens is substantially dissipated by the time the next pulse reaches the sample material. A probe light beam, which in a specific embodiment is a relatively low power, continuous wave (Cw) laser beam, irradiates the thermal lens formed in the sample material. The intensity characteristics of the probe light beam subsequent to irradiation of the thermal lens is related to changes in the refractive index of the sample material as the thermal lens is formed and dissipated. A plot of the changes in refractive index as a function of time during formation of the thermal lens as reflected by changes in intensity of the probe beam, provides a curve related to molecular relaxation characteristics of the material, and a plot during dissipation of the thermal lens provides a curve related to the thermal diffusivity of the sample material

  17. Novel information theory based method for superimposition of lateral head radiographs and cone beam computed tomography images

    Science.gov (United States)

    Jacquet, W; Nyssen, E; Bottenberg, P; de Groen, P; Vande Vannet, B

    2010-01-01

    Objectives The aim was to introduce a novel alignment criterion, focus mutual information (FMI), for the superimposition of lateral cephalometric radiographs and three dimensional (3D) cone beam computed images as well as the assessment of the alignment characteristics of the new method and comparison of the novel methodology with the region of interest (ROI) approach. Methods Implementation of a FMI criterion-based methodology that only requires the approximate indication of stable structures in one single image. The robustness of the method was first addressed in a phantom experiment comparing the new technique with a ROI approach. Two consecutive cephalometric radiographs were then obtained, one before and one after functional twin block application. These images were then superimposed using alignment by FMI where the following were focused on, in several ways: (1) cranial base and acoustic meatus, (2) palatal plane and (3) mandibular symphysis. The superimposed images were subtracted and coloured. The applicability to cone beam CT (CBCT) is illustrated by the alignment of CBCT images acquired before and after craniofacial surgery. Results The phantom experiment clearly shows superior alignment when compared to the ROI approach (Wilcoxon n = 17, Z = −3.290, and P = 0.001), and robustness with respect to the choice of parameters (one-sample t-test n = 50, t = −12.355, and P = 0.000). The treatment effects are revealed clearly in the subtraction image of well-aligned cephalometric radiographs. The colouring scheme of the subtraction image emphasises the areas of change and visualizes the remodelling of the soft tissue. Conclusions FMI allows for cephalometry without tracing, it avoids the error inherent to the use of landmarks and the interaction of the practitioner is kept to a minimum. The robustness to focal distribution variations limits the influence of possible examiner inaccuracy. PMID:20395459

  18. An Electromagnetic Beam Converter

    DEFF Research Database (Denmark)

    2009-01-01

    The present invention relates to an electromagnetic beam converter and a method for conversion of an input beam of electromagnetic radiation having a bell shaped intensity profile a(x,y) into an output beam having a prescribed target intensity profile l(x',y') based on a further development...

  19. A dental implant-based registration method for measuring mandibular kinematics using cone beam computed tomography-based fluoroscopy.

    Science.gov (United States)

    Lin, Cheng-Chung; Chen, Chien-Chih; Chen, Yunn-Jy; Lu, Tung-Wu; Hong, Shih-Wun

    2014-01-01

    This study aimed to develop and evaluate experimentally an implant-based registration method for measuring three-dimensional (3D) kinematics of the mandible and dental implants in the mandible based on dental cone beam computed tomography (CBCT), modified to include fluoroscopic function. The proposed implant-based registration method was based on the registration of CBCT data of implants/bones with single-plane fluoroscopy images. Seven registration conditions that included one to three implants were evaluated experimentally for their performance in a cadaveric porcine headmodel. The implant-based registration method was shown to have measurement errors (SD) of less than -0.2 (0.3) mm, 1.1 (2.2) mm, and 0.7 degrees (1.3 degrees) for the in-plane translation, out-of-plane translation, and all angular components, respectively, regardless of the number of implants used. The corresponding errors were reduced to less than -0.1 (0.1) mm, -0.3 (1.7) mm, and 0.5 degree (0.4 degree) when three implants were used. An implant-based registration method was developed to measure the 3D kinematics of the mandible/implants. With its high accuracy and reliability, the new method will be useful for measuring the 3D motion of the bones/implants for relevant applications.

  20. A general framework and review of scatter correction methods in cone beam CT. Part 2: Scatter estimation approaches

    International Nuclear Information System (INIS)

    Ruehrnschopf and, Ernst-Peter; Klingenbeck, Klaus

    2011-01-01

    The main components of scatter correction procedures are scatter estimation and a scatter compensation algorithm. This paper completes a previous paper where a general framework for scatter compensation was presented under the prerequisite that a scatter estimation method is already available. In the current paper, the authors give a systematic review of the variety of scatter estimation approaches. Scatter estimation methods are based on measurements, mathematical-physical models, or combinations of both. For completeness they present an overview of measurement-based methods, but the main topic is the theoretically more demanding models, as analytical, Monte-Carlo, and hybrid models. Further classifications are 3D image-based and 2D projection-based approaches. The authors present a system-theoretic framework, which allows to proceed top-down from a general 3D formulation, by successive approximations, to efficient 2D approaches. A widely useful method is the beam-scatter-kernel superposition approach. Together with the review of standard methods, the authors discuss their limitations and how to take into account the issues of object dependency, spatial variance, deformation of scatter kernels, external and internal absorbers. Open questions for further investigations are indicated. Finally, the authors refer on some special issues and applications, such as bow-tie filter, offset detector, truncated data, and dual-source CT.

  1. Discussion of the Improved Methods for Analyzing a Cantilever Beam Carrying a Tip-Mass under Base Excitation

    Directory of Open Access Journals (Sweden)

    Wang Hongjin

    2014-01-01

    Full Text Available Two improved analytical methods of calculations for natural frequencies and mode shapes of a uniform cantilever beam carrying a tip-mass under base excitation are presented based on forced vibration theory and the method of separation of variables, respectively. The cantilever model is simplified in detail by replacing the tip-mass with an equivalent inertial force and inertial moment acting at the free end of the cantilever based on D’Alembert’s principle. The concentrated equivalent inertial force and inertial moment are further represented as distributed loads using Dirac Delta Function. In this case, some typical natural frequencies and mode shapes of the cantilever model are calculated by the improved and unimproved analytical methods. The comparing results show that, after improvement, these two methods are in extremely good agreement with each other even the offset distance between the gravity center of the tip-mass and the attachment point is large. As further verification, the transient and steady displacement responses of the cantilever system under a sine base excitation are presented in which two improved methods are separately utilized. Finally, an experimental cantilever system is fabricated and the theoretical displacement responses are validated by the experimental measurements successfully.

  2. SU-D-206-03: Segmentation Assisted Fast Iterative Reconstruction Method for Cone-Beam CT

    International Nuclear Information System (INIS)

    Wu, P; Mao, T; Gong, S; Wang, J; Niu, T; Sheng, K; Xie, Y

    2016-01-01

    Purpose: Total Variation (TV) based iterative reconstruction (IR) methods enable accurate CT image reconstruction from low-dose measurements with sparse projection acquisition, due to the sparsifiable feature of most CT images using gradient operator. However, conventional solutions require large amount of iterations to generate a decent reconstructed image. One major reason is that the expected piecewise constant property is not taken into consideration at the optimization starting point. In this work, we propose an iterative reconstruction method for cone-beam CT (CBCT) using image segmentation to guide the optimization path more efficiently on the regularization term at the beginning of the optimization trajectory. Methods: Our method applies general knowledge that one tissue component in the CT image contains relatively uniform distribution of CT number. This general knowledge is incorporated into the proposed reconstruction using image segmentation technique to generate the piecewise constant template on the first-pass low-quality CT image reconstructed using analytical algorithm. The template image is applied as an initial value into the optimization process. Results: The proposed method is evaluated on the Shepp-Logan phantom of low and high noise levels, and a head patient. The number of iterations is reduced by overall 40%. Moreover, our proposed method tends to generate a smoother reconstructed image with the same TV value. Conclusion: We propose a computationally efficient iterative reconstruction method for CBCT imaging. Our method achieves a better optimization trajectory and a faster convergence behavior. It does not rely on prior information and can be readily incorporated into existing iterative reconstruction framework. Our method is thus practical and attractive as a general solution to CBCT iterative reconstruction. This work is supported by the Zhejiang Provincial Natural Science Foundation of China (Grant No. LR16F010001), National High-tech R

  3. A method of adjusting SUV for injection-acquisition time differences in {sup 18}F-FDG PET Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Laffon, Eric [Hopital du Haut Leveque, CHU de Bordeaux, Pessac (France); Centre de Recherche Cardio-Thoracique, Bordeaux (France); Hopital du Haut-Leveque, Service de Medecine Nucleaire, Pessac (France); Clermont, Henri de [Hopital du Haut Leveque, CHU de Bordeaux, Pessac (France); Marthan, Roger [Hopital du Haut Leveque, CHU de Bordeaux, Pessac (France); Centre de Recherche Cardio-Thoracique, Bordeaux (France)

    2011-11-15

    A time normalisation method of tumour SUVs in {sup 18}F-FDG PET imaging is proposed that has been verified in lung cancer patients. A two-compartment model analysis showed that, when SUV is not corrected for {sup 18}F physical decay (SUV{sub uncorr}), its value is within 5% of its peak value (t = 79 min) between 55 and 110 min after injection, in each individual patient. In 10 patients, each with 1 or more malignant lesions (n = 15), two PET acquisitions were performed within this time delay, and the maximal SUV of each lesion, both corrected and uncorrected, was assessed. No significant difference was found between the two uncorrected SUVs, whereas there was a significant difference between the two corrected ones: mean differences were 0.04 {+-} 0.22 and 3.24 {+-} 0.75 g.ml{sup -1}, respectively (95% confidence intervals). Therefore, a simple normalisation of decay-corrected SUV for time differences after injection is proposed: SUV{sub N} = 1.66*SUV{sub uncorr}, where the factor 1.66 arises from decay correction at t = 79 min. When {sup 18}F-FDG PET imaging is performed within the range 55-110 min after injection, a simple SUV normalisation for time differences after injection has been verified in patients with lung cancer, with a {+-}2.5% relative measurement uncertainty. (orig.)

  4. Assessment of Two Analytical Methods in Solving the Linear and Nonlinear Elastic Beam Deformation Problems

    DEFF Research Database (Denmark)

    Barari, Amin; Ganjavi, B.; Jeloudar, M. Ghanbari

    2010-01-01

    Purpose – In the last two decades with the rapid development of nonlinear science, there has appeared ever-increasing interest of scientists and engineers in the analytical techniques for nonlinear problems. This paper considers linear and nonlinear systems that are not only regarded as general...... boundary value problems, but also are used as mathematical models in viscoelastic and inelastic flows. The purpose of this paper is to present the application of the homotopy-perturbation method (HPM) and variational iteration method (VIM) to solve some boundary value problems in structural engineering...... and fluid mechanics. Design/methodology/approach – Two new but powerful analytical methods, namely, He's VIM and HPM, are introduced to solve some boundary value problems in structural engineering and fluid mechanics. Findings – Analytical solutions often fit under classical perturbation methods. However...

  5. SU-E-T-353: Decoding the Beam Complexity in Intensity-Modulated Radiation Therapy Plans

    International Nuclear Information System (INIS)

    Du, W; Cho, S; Zhang, X; Hoffman, K; Kudchadker, R

    2014-01-01

    Purpose: Modern IMRT relies on computers to generate treatment plans of varied complexity. A highly complex treatment plan may use a large number of small and irregular beam apertures in order to achieve high dose conformity. However, excessive beam complexity can increase dosimetric uncertainty, prolong treatment time, and increase susceptibility to target or organ motion. In this study we sought to develop metrics to assess the complexity of IMRT beams and plans. Methods: Based the information of leaf positions and MU for each beam segment, we calculated the following beam complexity metrics: aperture area, shape irregularity, and beam modulation. Then these beam complexity metrics were averaged to obtain the corresponding plan complexity metrics, using the beam MUs as weighting factors. We evaluated and compared the beam and plan complexity scores for 65 IMRT plans from 3 sites (prostate, head and neck, and spine). We also studied how the plan complexity scores were affected by adjusting inverse planning parameters. Results: For prostate IMRT, the lateral beams had large MUs and smaller shape irregularity, while the anterior or posterior beams had larger modulation values. On average, the prostate IMRT plans had the smallest shape irregularity and beam modulation; the HN IMRT plans had the largest aperture area, shape irregularity, and beam modulation; and the spine stereotactic IMRT plans often had small aperture area, which may be associated with relatively large discrepancies between calculated and measures doses. The plan complexity increased as the number of optimization iterations and the number of beam segments increased and as the minimum segment area decreased. Conclusion: Complexity of IMRT beams and plans were quantified in terms of aperture area, shape irregularity and beam modulation. The complexity metrics varied among IMRT plans for different disease sites and were affected when the planning parameters were adjusted

  6. The significance of amlodipine on autonomic nervous system adjustment (ANSA method: A new approach in the treatment of hypertension

    Directory of Open Access Journals (Sweden)

    Milovanović Branislav

    2009-01-01

    Full Text Available Introduction. Cardiovascular autonomic modulation is altered in patients with essential hypertension. Objective To evaluate acute and long-term effects of amlodipine on cardiovascular autonomic function and haemodynamic status in patients with mild essential hypertension. Methods. Ninety patients (43 male, mean age 52.12 ±10.7 years with mild hypertension were tested before, 30 minutes after the first 5 mg oral dose of amlodipine and three weeks after monotherapy with amlodipine. A comprehensive study protocol was done including finger blood pressure variability (BPV and heart rate variability (HRV beat-to-beat analysis with impedance cardiography, ECG with software short-term HRV and nonlinear analysis, 24-hour Holter ECG monitoring with QT and HRV analysis, 24-hour blood pressure (BP monitoring with systolic and diastolic BPV analysis, cardiovascular autonomic reflex tests, cold pressure test, mental stress test. The patients were also divided into sympathetic and parasympathetic groups, depending on predominance in short time spectral analysis of sympathovagal balance according to low frequency and high frequency values. Results. We confirmed a significant systolic and diastolic BP reduction, and a reduction of pulse pressure during day, night and early morning hours. The reduction of supraventricular and ventricular ectopic beats during the night was also achieved with therapy, but without statistical significance. The increment of sympathetic activity in early phase of amlodipine therapy was without statistical significance and persistence of sympathetic predominance after a few weeks of therapy detected based on the results of short-term spectral HRV analysis. All time domain parameters of long-term HRV analysis were decreased and low frequency amongst spectral parameters. Amlodipne reduced baroreflex sensitivity after three weeks of therapy, but increased it immediately after the administration of the first dose. Conclusion. The results

  7. Brain tumors and synchrotron radiation: new methods for mini-beams radiation therapy and treatment follow-up by functional imaging

    International Nuclear Information System (INIS)

    Deman, P.

    2012-01-01

    An innovative method of synchrotron radiation therapy, called mini-beams, was proposed by A. Dilmanian et al. in 2006. Mini-beams consists in tumor irradiation with monochromatic sub-millimetric x-ray beams spatially fractionated produced by a synchrotron source. To obtain a homogeneous dose in the target volume, an interleaving is realized using two orthogonal incidences. Adjacent healthy tissue is only partially irradiated by mini-beams, the areas between the beams only receive scattered radiation and therefore the energy deposited is 10 to 15 times lower than on one mini-beam axis, leading to a sparing effect of healthy tissue even when a high dose is deposited in the target volume. The thesis project is the development of this experimental method of monochromatic mini-beams, which involves the control of the irradiation geometry, the control of dosimetry and its modeling by Monte Carlo simulations. To evaluate the method, preclinical experiments on models of brain tumors implanted in rats (F98) are performed. Follow-up by anatomical and functional imaging is carried out to evaluate the effectiveness of the treatment. Functional imaging of cerebral perfusion (volume and cerebral blood flow, mean transit time of heavy elements) appears to be associated in the literature as a relevant method for monitoring prognostic. The key parameters of the cerebral vasculature are mainly studied in magnetic resonance imaging (MRI), because of the harmlessness of this imaging modality. The relation between MRI signal and contrast agent concentration is very complex and no quantitative relationship is well known. Synchrotron Radiation Computed Tomography (SRCT) is an imaging modality with performances to measure absolute contrast agent concentration very close to the theoretical limits and can be used as gold-standard. The used pharmacokinetic models need as input parameters a contrast agent concentration versus time. A comparison of perfusion measurements between MRI and SRCT

  8. Comparison of two methods for minimizing the effect of delayed charge on the dose delivered with a synchrotron based discrete spot scanning proton beam

    International Nuclear Information System (INIS)

    Whitaker, Thomas J.; Beltran, Chris; Tryggestad, Erik; Kruse, Jon J.; Remmes, Nicholas B.; Tasson, Alexandria; Herman, Michael G.; Bues, Martin

    2014-01-01

    Purpose: Delayed charge is a small amount of charge that is delivered to the patient after the planned irradiation is halted, which may degrade the quality of the treatment by delivering unwarranted dose to the patient. This study compares two methods for minimizing the effect of delayed charge on the dose delivered with a synchrotron based discrete spot scanning proton beam. Methods: The delivery of several treatment plans was simulated by applying a normally distributed value of delayed charge, with a mean of 0.001(SD 0.00025) MU, to each spot. Two correction methods were used to account for the delayed charge. Method one (CM1), which is in active clinical use, accounts for the delayed charge by adjusting the MU of the current spot based on the cumulative MU. Method two (CM2) in addition reduces the planned MU by a predicted value. Every fraction of a treatment was simulated using each method and then recomputed in the treatment planning system. The dose difference between the original plan and the sum of the simulated fractions was evaluated. Both methods were tested in a water phantom with a single beam and simple target geometry. Two separate phantom tests were performed. In one test the dose per fraction was varied from 0.5 to 2 Gy using 25 fractions per plan. In the other test the number fractions were varied from 1 to 25, using 2 Gy per fraction. Three patient plans were used to determine the effect of delayed charge on the delivered dose under realistic clinical conditions. The order of spot delivery using CM1 was investigated by randomly selecting the starting spot for each layer, and by alternating per layer the starting spot from first to last. Only discrete spot scanning was considered in this study. Results: Using the phantom setup and varying the dose per fraction, the maximum dose difference for each plan of 25 fractions was 0.37–0.39 Gy and 0.03–0.05 Gy for CM1 and CM2, respectively. While varying the total number of fractions, the maximum dose

  9. Ultrasonic lateral modulation imaging, speckle reduction, and displacement vector measurements using simple single-beam scanning or plural crossed-beam scanning with new spectra frequency division processing methods

    Directory of Open Access Journals (Sweden)

    Sumi C

    2012-10-01

    Full Text Available Chikayoshi Sumi, Yousuke IshiiDepartment of Information and Communication Sciences, Faculty of Science and Technology, Sophia University, Tokyo, JapanAbstract: The development of effective ultrasonic tissue displacement measurement methods increases the number of possible applications for various tissue displacement and strain measurements. These applications include measurements of spontaneous motions/deformations generated by heart motion; pulsations from phenomena such as blood flow (intracardiac, intravascular, and carotid; heart, blood vessel, and liver motion; and motion from artificial sources such as motions/deformations generated by applying static compression/stretching forces, vibration or acoustic radiation forces (breast and liver. For arbitrary orthogonal coordinate systems obtained using arbitrary transducer types (eg, linear, convex, sector, arc, or radial array types, or single aperture types with a mechanical scan, several lateral modulation (LM methods (eg, scanning with plural crossed or steered beams over a region of interest have been developed that can be used with new echo imaging methods for tissue displacement/deformation measurements. Specifically, by using such beamforming methods, in addition to highly accurate displacement vector and lateral displacement measurements, LM echo imaging with a high lateral carrier frequency and a high lateral resolution has been developed. Another new beamforming method, referred to as “a steering angle (ASTA method,” ie, scanning with a defined steering angle, is also described. In addition to conventional non-steered-beam scanning (ie, a version of ASTA and conventional steered-beam scanning with a variable steering angle (eg, sector, arc, radial scan, a simple, single-beam scanning method also permits the use of LM, which yields an accurate displacement vector measurement with fewer calculations than the original LM methods. This is accomplished by using a previously developed

  10. Terascale Beam-Beam Simulations for Tevatron, RHIC and LHC

    Energy Technology Data Exchange (ETDEWEB)

    Qiang, J.

    2005-05-16

    In this paper, we report on recent advances in terascale simulations of the beam-beam interaction in Tevatron, RHIC and LHC.Computational methods for self consistent calculation of beam-beam forces are reviewed. New method for solving the two-dimensional Poisson equation with open boundary conditions is proposed and tested. This new spectral-finite difference method is a factor of four faster than the widely used FFT based Green function method for beam-beam interaction on axis. We also present applications to the study of antiproton losses during the injection stage at Tevatron, to the study of multiple bunch coherent beam-beam modes at RHIC, and to the study of beam-beam driven emittance growth at LHC.

  11. Terascale Beam-Beam Simulations for Tevatron, RHIC and LHC

    International Nuclear Information System (INIS)

    Qiang, J.

    2005-01-01

    In this paper, we report on recent advances in terascale simulations of the beam-beam interaction in Tevatron, RHIC and LHC.Computational methods for self consistent calculation of beam-beam forces are reviewed. New method for solving the two-dimensional Poisson equation with open boundary conditions is proposed and tested. This new spectral-finite difference method is a factor of four faster than the widely used FFT based Green function method for beam-beam interaction on axis. We also present applications to the study of antiproton losses during the injection stage at Tevatron, to the study of multiple bunch coherent beam-beam modes at RHIC, and to the study of beam-beam driven emittance growth at LHC

  12. MO-F-CAMPUS-I-04: Characterization of Fan Beam Coded Aperture Coherent Scatter Spectral Imaging Methods for Differentiation of Normal and Neoplastic Breast Structures

    Energy Technology Data Exchange (ETDEWEB)

    Morris, R; Albanese, K; Lakshmanan, M; Greenberg, J; Kapadia, A [Duke University Medical Center, Durham, NC, Carl E Ravin Advanced Imaging Laboratories, Durham, NC (United States)

    2015-06-15

    Purpose: This study intends to characterize the spectral and spatial resolution limits of various fan beam geometries for differentiation of normal and neoplastic breast structures via coded aperture coherent scatter spectral imaging techniques. In previous studies, pencil beam raster scanning methods using coherent scatter computed tomography and selected volume tomography have yielded excellent results for tumor discrimination. However, these methods don’t readily conform to clinical constraints; primarily prolonged scan times and excessive dose to the patient. Here, we refine a fan beam coded aperture coherent scatter imaging system to characterize the tradeoffs between dose, scan time and image quality for breast tumor discrimination. Methods: An X-ray tube (125kVp, 400mAs) illuminated the sample with collimated fan beams of varying widths (3mm to 25mm). Scatter data was collected via two linear-array energy-sensitive detectors oriented parallel and perpendicular to the beam plane. An iterative reconstruction algorithm yields images of the sample’s spatial distribution and respective spectral data for each location. To model in-vivo tumor analysis, surgically resected breast tumor samples were used in conjunction with lard, which has a form factor comparable to adipose (fat). Results: Quantitative analysis with current setup geometry indicated optimal performance for beams up to 10mm wide, with wider beams producing poorer spatial resolution. Scan time for a fixed volume was reduced by a factor of 6 when scanned with a 10mm fan beam compared to a 1.5mm pencil beam. Conclusion: The study demonstrates the utility of fan beam coherent scatter spectral imaging for differentiation of normal and neoplastic breast tissues has successfully reduced dose and scan times whilst sufficiently preserving spectral and spatial resolution. Future work to alter the coded aperture and detector geometries could potentially allow the use of even wider fans, thereby making coded

  13. Methods and approaches to provide feedback from nuclear and covariance data adjustment for improvement of nuclear data files. SG39 meeting, December 2015

    International Nuclear Information System (INIS)

    Cabellos, Oscar; De Saint Jean, Cyrille; Hursin, Mathieu; Pelloni, Sandro; Ivanov, Evgeny; Kodeli, Ivan; Leconte, Pierre; Palmiotti, Giuseppe; Salvatores, Massimo; Sobes, Vladimir; Yokoyama, Kenji

    2015-12-01

    The aim of WPEC subgroup 39 'Methods and approaches to provide feedback from nuclear and covariance data adjustment for improvement of nuclear data files' is to provide criteria and practical approaches to use effectively the results of sensitivity analyses and cross section adjustments for feedback to evaluators and differential measurement experimentalists in order to improve the knowledge of neutron cross sections, uncertainties, and correlations to be used in a wide range of applications. This document is the proceedings of the fifth formal Subgroup 39 meeting held at the Institute Curie, Paris, France, on 4 December 2015. It comprises a Summary Record of the meeting, and all the available presentations (slides) given by the participants: A - Sensitivity methods: - 1: Short update on deliverables (K. Yokoyama); - 2: Does one shot Bayesian is equivalent to successive update? Bayesian inference: some matrix linear algebra (C. De Saint Jean); - 3: Progress in Methodology (G. Palmiotti); - SG39-3: Use of PIA approach. Possible application to neutron propagation experiments (S. Pelloni); - 4: Update on sensitivity coefficient methods (E. Ivanov); - 5: Stress test for U-235 fission (H. Wu); - 6: Methods and approaches development at ORNL for providing feedback from integral benchmark experiments for improvement of nuclear data files (V. Sobes); B - Integral experiments: - 7a: Update on SEG analysis (G. Palmiotti); - 7b:Status of MANTRA (G. Palmiotti); - 7c: Possible new experiments at NRAD (G. Palmiotti); - 8: B-eff experiments (I. Kodeli); - 9: On going CEA activities related to dedicated integral experiments for nuclear date validation in the Fast energy range (P. Leconte); - 10: PROTEUS Experiments: an update (M. Hursin); - 11: Short updates on neutron propagation experiments, STEK, CIELO status (O. Cabellos)

  14. Method of generating intense nuclear polarized beams by selective photodetachment of negative ions

    International Nuclear Information System (INIS)

    Hershcovitch, A.

    1986-01-01

    A novel method for production of nuclear polarized negative hydrogen ions by selective neutralization with a laser of negative hydrogen ions in a magnetic field is described. This selectivity is possible since a final state of the neutralized atom, and hence the neutralization energy, depends on its nuclear polarization. The main advantages of this scheme are the availability of multi-ampere negative ion sources and the possibility of neutralizing negative ions with very high efficiency. An assessment of the required laser power indicates that this method is in principle feasible with today's technology

  15. Developing and setting up optical methods to study the speckle patterns created by optical beam smoothing

    International Nuclear Information System (INIS)

    Surville, J.

    2005-12-01

    We have developed three main optical methods to study the speckles generated by a smoothed laser source. The first method addresses the measurement of the temporal and spatial correlation functions of the source, with a modified Michelson interferometer. The second one is a pump-probe technique created to shoot a picture of a speckle pattern generated at a set time. And the third one is an evolution of the second method dedicated to time-frequency coding, thanks to a frequency chirped probe pulse. Thus, the speckles can be followed in time and their motion can be described. According to these three methods, the average size and duration of the speckles can be measured. It is also possible to measure the size and the duration of each of them and mostly their velocity in a given direction. All the results obtained have been confronted to the different existing theories. We show that the statistical distributions of the measured speckles'size and speckles'intensity agree satisfactorily with theoretical values

  16. A NEW METHOD FOR MEASURING NEUTRON-SKIN THICKNESS IN RARE ISOTOPE BEAMS

    NARCIS (Netherlands)

    Krasznahorkay, A.; Csatlos, M.; Stuhl, L.; Algora, A.; Gulyas, J.; Timar, J.; Paar, N.; Vretenar, D.; Harakeh, M. N.

    A new method, based on the excitation of the anti-analog giant dipole resonance (AGDR) in (p, n) reaction, for measuring the neutron-skin thickness has been tested. The gamma-decay of the AGDR to the isobaric analog state (IAS) has been measured. The difference in excitation energy of the AGDR and

  17. Ray tracing method for simulation of laser beam interaction with random packings of powders

    Science.gov (United States)

    Kovalev, O. B.; Kovaleva, I. O.; Belyaev, V. V.

    2018-03-01

    Selective laser sintering is a technology of rapid manufacturing of a free form that is created as a solid object by selectively fusing successive layers of powder using a laser. The motivation of this study is due to the currently insufficient understanding of the processes and phenomena of selective laser melting of powders whose time scales differ by orders of magnitude. To construct random packings from mono- and polydispersed solid spheres, the algorithm of their generation based on the discrete element method is used. A numerical method of ray tracing is proposed that is used to simulate the interaction of laser radiation with a random bulk packing of spherical particles and to predict the optical properties of the granular layer, the extinction and absorption coefficients, depending on the optical properties of a powder material.

  18. Method of targeted delivery of laser beam to isolated retinal rods by fiber optics.

    Science.gov (United States)

    Sim, Nigel; Bessarab, Dmitri; Jones, C Michael; Krivitsky, Leonid

    2011-11-01

    A method of controllable light delivery to retinal rod cells using an optical fiber is described. Photo-induced current of the living rod cells was measured with the suction electrode technique. The approach was tested with measurements relating the spatial distribution of the light intensity to photo-induced current. In addition, the ion current responses of rod cells to polarized light at two different orientation geometries of the cells were studied.

  19. Development of laser-ion beam photodissociation methods. Progress report, December 1, 1992--November 30, 1993

    Energy Technology Data Exchange (ETDEWEB)

    Russell, D.H.

    1992-08-01

    Research efforts were concentrated on developing the tandem magnetic sector (EB)/reflection-time-of-flight (TOF) instrument, preliminary experiments with tandem TOF/TOF instruments, developing method for performing photodissociation with pulsed lasers, experiments with laser ionization of aerosol particles, matrix-assisted laser desorption ionization (MALDI), and ion-molecule reaction chemistry of ground and excited state transition metal ions. This progress report is divided into: photodissociation, MALDI (including aerosols), and ion chemistry fundamentals.

  20. Moment method analysis of linearly tapered slot antennas: Low loss components for switched beam radiometers

    Science.gov (United States)

    Koeksal, Adnan; Trew, Robert J.; Kauffman, J. Frank

    1992-01-01

    A Moment Method Model for the radiation pattern characterization of single Linearly Tapered Slot Antennas (LTSA) in air or on a dielectric substrate is developed. This characterization consists of: (1) finding the radiated far-fields of the antenna; (2) determining the E-Plane and H-Plane beamwidths and sidelobe levels; and (3) determining the D-Plane beamwidth and cross polarization levels, as antenna parameters length, height, taper angle, substrate thickness, and the relative substrate permittivity vary. The LTSA geometry does not lend itself to analytical solution with the given parameter ranges. Therefore, a computer modeling scheme and a code are necessary to analyze the problem. This necessity imposes some further objectives or requirements on the solution method (modeling) and tool (computer code). These may be listed as follows: (1) a good approximation to the real antenna geometry; and (2) feasible computer storage and time requirements. According to these requirements, the work is concentrated on the development of efficient modeling schemes for these type of problems and on reducing the central processing unit (CPU) time required from the computer code. A Method of Moments (MoM) code is developed for the analysis of LTSA's within the parameter ranges given.

  1. Ion beam-induced luminescence as method of characterization of radiation damage in polycrystalline materials

    Energy Technology Data Exchange (ETDEWEB)

    Jozwik, Iwona, E-mail: iwona.jozwik@itme.edu.pl [Institute of Electronic Materials Technology, Wolczynska 133, 01-919 Warsaw (Poland); Jagielski, Jacek [Institute of Electronic Materials Technology, Wolczynska 133, 01-919 Warsaw (Poland); National Centre for Nuclear Research, Soltana 7, 05-400 Otwock/Swierk (Poland); Gawlik, Grzegorz [Institute of Electronic Materials Technology, Wolczynska 133, 01-919 Warsaw (Poland); Panczer, Gerard [Institut Lumière Matière ILM, UMR5306 Université Lyon 1-CNRS, Université de Lyon, Villeurbanne (France); Moncoffre, Nathalie [Institut de Physique Nucléaire de Lyon IPNL, Université de Lyon, Université Lyon 1, CNRS/IN2P3, UMR 5822, Villeurbanne (France); Ratajczak, Renata [National Centre for Nuclear Research, Soltana 7, 05-400 Otwock/Swierk (Poland); Jozwik, Przemyslaw [Institute of Electronic Materials Technology, Wolczynska 133, 01-919 Warsaw (Poland); National Centre for Nuclear Research, Soltana 7, 05-400 Otwock/Swierk (Poland); Wajler, Anna; Sidorowicz, Agata [Institute of Electronic Materials Technology, Wolczynska 133, 01-919 Warsaw (Poland); Thomé, Lionel [Centre de Spectrometrie Nucleaire et de Spectrometrie de Masse, CNRS/IN2P3, Universite Paris-Sud, Bat. 108, F-91405 Orsay (France)

    2015-12-15

    The problem of information about damage build-up, intensively studied for single crystals, poses many difficulties for polycrystalline materials. The Rutherford Backscattering/Channeling (RBS/C) technique could be applied for single crystals only, but its use is excluded in polycrystalline materials. Therefore the development of a quantitative method well suited for the evaluation of damage level in polycrystalline materials is a must, and still constitutes a major challenge in materials analysis. A comparative study of damage accumulation in magnesium aluminate spinel (MgAl{sub 2}O{sub 4}) has been conducted using ionoluminescence (IL) and RBS/C techniques. The results obtained by both methods, demonstrate a two-step character of damage build-up process. The values of the cross-section on the damage creation in each case were estimated using MSDA model. The results presented here confirm the huge potential of the luminescence techniques for damage analysis in single- and polycrystalline samples, and ability of the IL method to perform fast, in situ analysis of damage accumulation process.

  2. A method for measuring coherent elastic neutrino-nucleus scattering at a far off-axis high-energy neutrino beam target

    Energy Technology Data Exchange (ETDEWEB)

    Brice, S. J. [Fermilab; Cooper, R. L. [Indiana U.; DeJongh, F. [Fermilab; Empl, A. [Houston U.; Garrison, L. M. [Indiana U.; Hime, A. [Los Alamos; Hungerford, E. [Houston U.; Kobilarcik, T. [Fermilab; Loer, B. [Fermilab; Mariani, C. [Virginia Tech.; Mocko, M. [Los Alamos; Muhrer, G. [Los Alamos; Pattie, R. [North Carolina State U.; Pavlovic, Z. [Los Alamos; Ramberg, E. [Fermilab; Scholberg, K. [Duke U.; Tayloe, R. [Indiana U.; Thornton, R. T. [Indiana U.; Yoo, J. [Fermilab; Young, A. [North Carolina State U.

    2014-04-03

    We present an experimental method for measuring the process of coherent elastic neutrino-nucleus scattering (CENNS). This method uses a detector situated transverse to a high-energy neutrino beam production target. This detector would be sensitive to the low-energy neutrinos arising from decay-at-rest pions in the target. We discuss the physics motivation for making this measurement and outline the predicted backgrounds and sensitivities using this approach. We report a measurement of neutron backgrounds as found in an off-axis surface location of the Fermilab Booster Neutrino Beam (BNB) target. The results indicate that the Fermilab BNB target is a favorable location for a CENNS experiment.

  3. High Energy Laser Beam Propagation in the Atmosphere: The Integral Invariants of the Nonlinear Parabolic Equation and the Method of Moments

    Science.gov (United States)

    Manning, Robert M.

    2012-01-01

    The method of moments is used to define and derive expressions for laser beam deflection and beam radius broadening for high-energy propagation through the Earth s atmosphere. These expressions are augmented with the integral invariants of the corresponding nonlinear parabolic equation that describes the electric field of high-energy laser beam to propagation to yield universal equations for the aforementioned quantities; the beam deflection is a linear function of the propagation distance whereas the beam broadening is a quadratic function of distance. The coefficients of these expressions are then derived from a thin screen approximation solution of the nonlinear parabolic equation to give corresponding analytical expressions for a target located outside the Earth s atmospheric layer. These equations, which are graphically presented for a host of propagation scenarios, as well as the thin screen model, are easily amenable to the phase expansions of the wave front for the specification and design of adaptive optics algorithms to correct for the inherent phase aberrations. This work finds application in, for example, the analysis of beamed energy propulsion for space-based vehicles.

  4. The Heating Curve Adjustment Method

    NARCIS (Netherlands)

    Kornaat, W.; Peitsman, H.C.

    1995-01-01

    In apartment buildings with a collective heating system usually a weather compensator is used for controlling the heat delivery to the various apartments. With this weather compensator the supply water temperature to the apartments is regulated depending on the outside air temperature. With

  5. The effect of marriage on young adult heavy drinking and its mediators: results from two methods of adjusting for selection into marriage.

    Science.gov (United States)

    Lee, Matthew R; Chassin, Laurie; Mackinnon, David

    2010-12-01

    This study tested the effect of marriage on young adult heavy drinking and tested whether this effect was mediated by involvement in social activities, religiosity, and self-control reasons for limiting drinking. The sample of 508 young adults was taken from an ongoing longitudinal study of familial alcoholism that over-sampled children of alcoholics (Chassin, Rogosch, & Barrera, 1991). In order to distinguish role socialization effects of marriage from confounding effects of role selection into marriage, analyses used both the analysis of covariance (ANCOVA) method and the change score method of adjusting for pre-marriage levels of heavy drinking and the mediators. Results showed role socialization effects of marriage on post-marriage declines in heavy drinking. This effect was mediated by involvement in social activities such that marriage predicted decreased involvement in social activities, which in turn predicted decreased heavy drinking. There were no statistically significant mediated effects of religiosity. The mediated effect of self-control reasons for limiting drinking was supported by the ANCOVA method only, and further investigation suggested that this result was detected erroneously due to violation of an assumption of the ANCOVA method that is not shared by the change score method. Findings from this study offer an explanation for the maturing out of heavy drinking that takes place for some individuals over the course of young adulthood. Methodologically, results suggest that the ANCOVA method should be employed with caution, and that the change score method is a viable approach to confirming results from the ANCOVA method. (PsycINFO Database Record (c) 2010 APA, all rights reserved).

  6. Set up of a method for the adjustment of resonance parameters on integral experiments; Mise au point d`une methode d`ajustement des parametres de resonance sur des experiences integrales

    Energy Technology Data Exchange (ETDEWEB)

    Blaise, P.

    1996-12-18

    Resonance parameters for actinides play a significant role in the neutronic characteristics of all reactor types. All the major integral parameters strongly depend on the nuclear data of the isotopes in the resonance-energy regions.The author sets up a method for the adjustment of resonance parameters taking into account the self-shielding effects and restricting the cross section deconvolution problem to a limited energy region. (N.T.).

  7. Fourier continuation methods for high-fidelity simulation of nonlinear acoustic beams.

    Science.gov (United States)

    Albin, Nathan; Bruno, Oscar P; Cheung, Theresa Y; Cleveland, Robin O

    2012-10-01

    On the basis of recently developed Fourier continuation (FC) methods and associated efficient parallelization techniques, this text introduces numerical algorithms that, due to very low dispersive errors, can accurately and efficiently solve the types of nonlinear partial differential equation (PDE) models of nonlinear acoustics in hundred-wavelength domains as arise in the simulation of focused medical ultrasound. As demonstrated in the examples presented in this text, the FC approach can be used to produce solutions to nonlinear acoustics PDEs models with significantly reduced discretization requirements over those associated with finite-difference, finite-element and finite-volume methods, especially in cases involving waves that travel distances that are orders of magnitude longer than their respective wavelengths. In these examples, the FC methodology is shown to lead to improvements in computing times by factors of hundreds and even thousands over those required by the standard approaches. A variety of one-and two-dimensional examples presented in this text demonstrate the power and capabilities of the proposed methodology, including an example containing a number of scattering centers and nonlinear multiple-scattering events.

  8. A walk-free centroid method for lifetime measurements with pulsed beams

    International Nuclear Information System (INIS)

    Julin, R.; Kantele, J.; Luontama, M.; Passoja, A.; Poikolainen, T.

    1977-09-01

    A delayed-coincidence lifetime measurement method based on a comparison of walk-free centroids of time spectra is presented. The time is measured between the cyclotron RF signal and the pulse from a plastic scintillation detector followed by a fixed energy selection. The events to be time-analyzed are selected from the associated charge-particle spectrum of a silicon detector which is operated in coincidence with the scintillator, i.e., independently of the formation of the signal containing the time information. With this technique, with the micropulse FWHM of typically 500 to 700 ps, half-lives down to the 10 ps region can be measured. The following half-lives are obtained with the new method: 160+-6 ps for the 2032 keV level in 209 Pb; 45+-10 ps and 160+-20 ps for the 1756.8 keV (0 2 + ) and 2027.3 keV (0 3 + ) levels in 116 Sn, respectively. (author)

  9. Development of laser-ion beam photodissociation methods. Progress report, December 1991--November 1994

    Energy Technology Data Exchange (ETDEWEB)

    Russell, D.H.

    1994-06-01

    This project emphasizes the development of laser mass spectrometry methods for fundamental and applied studies of gas-phase processes. The current studies are focussed on the photochemistry and photophysics of peptides and other biological molecules. Matrix-assisted laser desorption ionization (MALDI) is used to produce ions that are subsequently subjected to photoexcitation and dissociation. MALDI is still very much in the developmental stages, thus a significant portion of this research focusses on fundamental studies of the MALDI ion formation/energy transfer process. The authors view is that excited state H+-transfer reactions play an important role in MALDI, consequently a significant portion of their research activities are focussed on such studies. Fundamental studies of the role of the matrix in MALDI are an integral part of this project. A new MALDI experiment, MALDI of aerosol particles generated from solutions, has been demonstrated and new developmental research in this area is planned. The authors are also actively pursuing a research program on gas-phase H+-transfer processes that mimic the MALDI process. In addition, they are developing photodissociation experiments, based on tandem time-of-flight mass spectrometers, for structural characterization of complex organic molecules. The photodissociation studies use MALDI as the ionization method. These research areas involve the development of new instrumentation, new instrument methodologies, and data processing.

  10. SU-D-207-04: GPU-Based 4D Cone-Beam CT Reconstruction Using Adaptive Meshing Method

    International Nuclear Information System (INIS)

    Zhong, Z; Gu, X; Iyengar, P; Mao, W; Wang, J; Guo, X

    2015-01-01

    Purpose: Due to the limited number of projections at each phase, the image quality of a four-dimensional cone-beam CT (4D-CBCT) is often degraded, which decreases the accuracy of subsequent motion modeling. One of the promising methods is the simultaneous motion estimation and image reconstruction (SMEIR) approach. The objective of this work is to enhance the computational speed of the SMEIR algorithm using adaptive feature-based tetrahedral meshing and GPU-based parallelization. Methods: The first step is to generate the tetrahedral mesh based on the features of a reference phase 4D-CBCT, so that the deformation can be well captured and accurately diffused from the mesh vertices to voxels of the image volume. After the mesh generation, the updated motion model and other phases of 4D-CBCT can be obtained by matching the 4D-CBCT projection images at each phase with the corresponding forward projections of the deformed reference phase of 4D-CBCT. The entire process of this 4D-CBCT reconstruction method is implemented on GPU, resulting in significantly increasing the computational efficiency due to its tremendous parallel computing ability. Results: A 4D XCAT digital phantom was used to test the proposed mesh-based image reconstruction algorithm. The image Result shows both bone structures and inside of the lung are well-preserved and the tumor position can be well captured. Compared to the previous voxel-based CPU implementation of SMEIR, the proposed method is about 157 times faster for reconstructing a 10 -phase 4D-CBCT with dimension 256×256×150. Conclusion: The GPU-based parallel 4D CBCT reconstruction method uses the feature-based mesh for estimating motion model and demonstrates equivalent image Result with previous voxel-based SMEIR approach, with significantly improved computational speed

  11. GANIL beam profile detectors

    International Nuclear Information System (INIS)

    Tribouillard, C.

    1997-01-01

    In the design phase of GANIL which started in 1977, one of the priorities of the project management was equipping the beamlines with a fast and efficient system for visualizing the beam position, thus making possible adjustment of the beam transport lines optics and facilitating beam control. The implantation of some thirty detectors was foreseen in the initial design. The assembly of installed detectors (around 190) proves the advantages of these detectors for displaying all the beams extracted from GANIL: transfer and transport lines, beam extracted from SISSI, very high intensity beam, secondary ion beams from the production target of the LISE and SPEG spectrometers, different SPIRAL project lines. All of these detectors are based on standard characteristics: - standard flange diameter (DN 160) with a standard booster for all the sensors; - identical analog electronics for all the detectors, with networking; - unique display system. The new micro-channel plate non-interceptive detectors (beam profile and ion packet lengths) make possible in-line control of the beam quality and accelerator stability. (author)

  12. A GRAMMATICAL ADJUSTMENT ANALYSIS OF STATISTICAL MACHINE TRANSLATION METHOD USED BY GOOGLE TRANSLATE COMPARED TO HUMAN TRANSLATION IN TRANSLATING ENGLISH TEXT TO INDONESIAN

    Directory of Open Access Journals (Sweden)

    Eko Pujianto

    2017-04-01

    Full Text Available Google translate is a program which provides fast, free and effortless translating service. This service uses a unique method to translate. The system is called ―Statistical Machine Translation‖, the newest method in automatic translation. Machine translation (MT is an area of many kinds of different subjects of study and technique from linguistics, computers science, artificial intelligent (AI, translation theory, and statistics. SMT works by using statistical methods and mathematics to process the training data. The training data is corpus-based. It is a compilation of sentences and words of the languages (SL and TL from translation done by human. By using this method, Google let their machine discovers the rules for themselves. They do this by analyzing millions of documents that have already been translated by human translators and then generate the result based on the corpus/training data. However, questions arise when the results of the automatic translation prove to be unreliable in some extent. This paper questions the dependability of Google translate in comparison with grammatical adjustment that naturally characterizes human translators' specific advantage. The attempt is manifested through the analysis of the TL of some texts translated by the SMT. It is expected that by using the sample of TL produced by SMT we can learn the potential flaws of the translation. If such exists, the partial of more substantial undependability of SMT may open more windows to the debates of whether this service may suffice the users‘ need.

  13. SU-F-T-225: Is It Time to Have Pre-Configured Therapeutic Beams Available in Commercial Treatment Planning Systems?

    International Nuclear Information System (INIS)

    Ding, G

    2016-01-01

    Purpose: Commissioning radiation beams requires considerable effort to obtain the beam data for beam configuration in a commercial treatment planning system. With the advances in technology, the manufacturer of accelerators now has the ability to adjust radiation beam parameters to meet pre-determined specifications with high precision. This study aims to illustrate the feasibility of making pre-configured radiation beams available in commercial treatment planning systems. Methods: In recent years, Varian has made a set of measured beam data from the TrueBeam accelerator available to users. Although the beam data are provided as “suggestive data” without warranty, the commissioned data measured by users have been shown to be in excellent agreement with the data set provided when the beams from the installed Linacs were adjusted to meet the beam specifications. An unofficial survey among Varian Linac TrueBeam users shows that the suggestive data set has been used with validation by users in some clinics. This indicates that radiation beams from a specified Linac can be standardized and pre-configured in a treatment planning system. Results: Two newly installed Varian TrueBeam accelerators at two different centers were examined in which one set of commissioned beam data was obtained from measurements performed by an independent physics consulting company and the other was measured by local physicists in the department. All beams from both accelerators were tuned to meet the manufacturer’s specifications. Discrepancies of less than 1% were found between the commissioned beam data from both accelerators and the suggestive data set provided by Varian. Conclusion: It may be feasible that radiation beams can be pre-configured in commercial treatment planning systems. The radiation beam users will perform the beam validation and end-to-end tests instead of configuring beams. This framework can increase both the efficiency and the accuracy in commercial radiation

  14. High gradient lens for charged particle beam

    Science.gov (United States)

    Chen, Yu-Jiuan

    2014-04-29

    Methods and devices enable shaping of a charged particle beam. A dynamically adjustable electric lens includes a series of alternating a series of alternating layers of insulators and conductors with a hollow center. The series of alternating layers when stacked together form a high gradient insulator (HGI) tube to allow propagation of the charged particle beam through the hollow center of the HGI tube. A plurality of transmission lines are connected to a plurality of sections of the HGI tube, and one or more voltage sources are provided to supply an adjustable voltage value to each transmission line of the plurality of transmission lines. By changing the voltage values supplied to each section of the HGI tube, any desired electric field can be established across the HGI tube. This way various functionalities including focusing, defocusing, acceleration, deceleration, intensity modulation and others can be effectuated on a time varying basis.

  15. A method of determining acoustical physical constants for piezoelectric materials by line-focus-beam acoustic microscopy.

    Science.gov (United States)

    Takanaga, Izumi; Kushibiki, Jun-ichi

    2002-07-01

    We developed a new method of determining acoustical physical constants (elastic constant, piezoelectric constant, dielectric constant, and density) of piezoelectric materials with high accuracy. This method acquires velocities of leaky surface acoustic waves (LSAWs) excited on the water-loaded specimen surface, measured by line-focus-beam (LFB) acoustic microscopy, and bulk velocities of longitudinal and shear waves, measured with plane-wave transducers replacing the LFB device in the same system, together with the dielectric constants and density measured independently, for a small number of specimens. For LiNbO3 and LiTaO3 crystals, we demonstrated that we could accurately determine the constants by choosing proper propagation directions of LSAWs and bulk waves for three principal X-, Y-, and Z-cut specimens and one rotated Y-cut specimen [(104) plate for LiNbO3 and (012) plate for LiTaOa]. The accuracy is nearly the same as that for the constants determined only from the bulk wave velocities.

  16. Accuracy of radiotherapy dose calculations based on cone-beam CT: comparison of deformable registration and image correction based methods

    Science.gov (United States)

    Marchant, T. E.; Joshi, K. D.; Moore, C. J.

    2018-03-01

    Radiotherapy dose calculations based on cone-beam CT (CBCT) images can be inaccurate due to unreliable Hounsfield units (HU) in the CBCT. Deformable image registration of planning CT images to CBCT, and direct correction of CBCT image values are two methods proposed to allow heterogeneity corrected dose calculations based on CBCT. In this paper we compare the accuracy and robustness of these two approaches. CBCT images for 44 patients were used including pelvis, lung and head & neck sites. CBCT HU were corrected using a ‘shading correction’ algorithm and via deformable registration of planning CT to CBCT using either Elastix or Niftyreg. Radiotherapy dose distributions were re-calculated with heterogeneity correction based on the corrected CBCT and several relevant dose metrics for target and OAR volumes were calculated. Accuracy of CBCT based dose metrics was determined using an ‘override ratio’ method where the ratio of the dose metric to that calculated on a bulk-density assigned version of the same image is assumed to be constant for each patient, allowing comparison to the patient’s planning CT as a gold standard. Similar performance is achieved by shading corrected CBCT and both deformable registration algorithms, with mean and standard deviation of dose metric error less than 1% for all sites studied. For lung images, use of deformed CT leads to slightly larger standard deviation of dose metric error than shading corrected CBCT with more dose metric errors greater than 2% observed (7% versus 1%).

  17. Analysis of adhesion test methods and the evaluation of their use for ion-beam-mixed metal/ceramic systems

    Energy Technology Data Exchange (ETDEWEB)

    Pawel, J.E.

    1988-07-01

    Several thin film adhesion tests have been examined to determine which provides the most reliable method for the measurement of the adhesion of thin metallic films to ceramic substrate. An attempt was made to use the testing techniques described to measure adhesion changes caused by ion beam mixing for a variety of metal/ceramic systems. The techniques analyzed were the scratch test, the acoustic-emission test, and the pull test. The major variables of the scratch test include film thickness, substrate hardness, and stylus radius, but it is not known precisely what effects changes in these have on the measurement of adhesion. The scratch analyses methods discussed in the literature, each describing a load or stress on the system that is presumed to cause de-adhesion, do not always hold because none of the analyses account for both plastic and elastic deformation or incorporate many of the important parameters. The scratch test was much more likely to reveal a critical value for de-adhesion for relatively brittle films such as chromium than for ductile films such as nickel. 65 refs, 29 figs, 17 tabs.

  18. A method to determine the detector locations of the cone-beam projection of the balls’ centers

    International Nuclear Information System (INIS)

    Deng, Lin; Xi, Xiaoqi; Li, Lei; Han, Yu; Yan, Bin

    2015-01-01

    In geometric calibration of cone-beam computed tomography (CBCT), sphere-like objects such as balls are widely imaged, the positioning information of which is obtained to determine the unknown geometric parameters. In this process, the accuracy of the detector location of CB projection of the center of the ball, which we call the center projection, is very important, since geometric calibration is sensitive to errors in the positioning information. Currently in almost all the geometric calibration using balls, the center projection is invariably estimated by the center of the support of the projection or the centroid of the intensity values inside the support approximately. Clackdoyle’s work indicates that the center projection is not always at the center of the support or the centroid of the intensity values inside, and has given a quantitative analysis of the maximum errors in evaluating the center projection by the centroid. In this paper, an exact method is proposed to calculate the center projection, utilizing both the detector location of the ellipse center and the two axis lengths of the ellipse. Numerical simulation results have demonstrated the precision and the robustness of the proposed method. Finally there are some comments on this work with non-uniform density balls, as well as the effect by the error occurred in the evaluation for the location of the orthogonal projection of the cone vertex onto the detector. (paper)

  19. Investigation of accelerated neutral atom beams created from gas cluster ion beams

    Science.gov (United States)

    Kirkpatrick, A.; Kirkpatrick, S.; Walsh, M.; Chau, S.; Mack, M.; Harrison, S.; Svrluga, R.; Khoury, J.

    2013-07-01

    A new concept for ultra-shallow processing of surfaces known as accelerated neutral atom beam (ANAB) technique employs conversion of energetic gas cluster ions produced by the gas cluster ion beam (GCIB) method into intense collimated beams of coincident neutral gas atoms having controllable average energies from less than 10 eV per atom to beyond 100 eV per atom. A beam of accelerated gas cluster ions is first produced as is usual in GCIB, but conditions within the source ionizer and extraction regions are adjusted such that immediately after ionization and acceleration the clusters undergo collisions with non-ionized gas atoms. Energy transfer during these collisions causes the energetic cluster ions to release many of their constituent atoms. An electrostatic deflector is then used to eliminate charged species, leaving the released neutral atoms to still travel collectively at the same velocities they had as bonded components of their parent clusters. Upon target impact, the accelerated neutral atom beams produce effects similar to those normally associated with GCIB, but to shallower depths, with less surface damage and with superior subsurface interfaces. The paper discusses generation and characterization of the accelerated neutral atom beams, describes interactions of the beams with target surfaces, and presents examples of ongoing work on applications for biomedical devices.

  20. Correct treatment of covers in adjustment of epithermal neutron spectra

    International Nuclear Information System (INIS)

    Seren, Tom; Kotiluoto, Petri; Auterinen, Iiro

    2006-01-01

    In activation measurements of strongly epithermal neutron fields, such as those encountered in BNCT, one frequently obtains higher reaction rates with covers (such as Cd or Gd) than without them for some reactions. This is due to downscatter of neutrons into energy regions with strong resonances. This effect cannot be accounted for with traditional methods for treating cover effects. A more proper way to handle the problem is to model the two neutron fields (with and without cover) separately and perform simultaneous adjustment of two correlated neutron fields. Unfortunately many adjustment codes cannot handle this situation. As an example adjustments of the neutron spectrum in the FiR 1 epithermal BNCT beam with the LSL-M2 code are presented and compared. (author)

  1. Beam-beam limit in e+e- circular colliders

    International Nuclear Information System (INIS)

    Ohmi, K.; Tawada, M.; Kamada, S.; Oide, K.; Cai, Y.; Qiang, J.

    2004-01-01

    Beam-beam effects limit the luminosity of circular colliders. Once the bunch population exceeds a threshold, the luminosity increases at a slower rate. This phenomenon is called the beam-beam limit. Onset of the beam-beam limit has been analyzed with various simulation methods based on the weak-strong and strong-strong models. We have observed that an incoherent phenomenon is mainly concerned in the beam-beam limit. The simulation have shown that equilibrium distributions of the two colliding beams are distorted from Gaussians when the luminosity is limited. The beam-beam limit is estimated to be ξ∼0.1 for a B factory with damping time of several thousand turns

  2. A novel method for quantification of beam's-eye-view tumor tracking performance.

    Science.gov (United States)

    Hu, Yue-Houng; Myronakis, Marios; Rottmann, Joerg; Wang, Adam; Morf, Daniel; Shedlock, Daniel; Baturin, Paul; Star-Lack, Josh; Berbeco, Ross

    2017-11-01

    In-treatment imaging using an electronic portal imaging device (EPID) can be used to confirm patient and tumor positioning. Real-time tumor tracking performance using current digital megavolt (MV) imagers is hindered by poor image quality. Novel EPID designs may help to improve quantum noise response, while also preserving the high spatial resolution of the current clinical detector. Recently investigated EPID design improvements include but are not limited to multi-layer imager (MLI) architecture, thick crystalline and amorphous scintillators, and phosphor pixilation and focusing. The goal of the present study was to provide a method of quantitating improvement in tracking performance as well as to reveal the physical underpinnings of detector design that impact tracking quality. The study employs a generalizable ideal observer methodology for the quantification of tumor tracking performance. The analysis is applied to study both the effect of increasing scintillator thickness on a standard, single-layer imager (SLI) design as well as the effect of MLI architecture on tracking performance. The present study uses the ideal observer signal-to-noise ratio (d') as a surrogate for tracking performance. We employ functions which model clinically relevant tasks and generalized frequency-domain imaging metrics to connect image quality with tumor tracking. A detection task for relevant Cartesian shapes (i.e., spheres and cylinders) was used to quantitate trackability of cases employing fiducial markers. Automated lung tumor tracking algorithms often leverage the differences in benign and malignant lung tissue textures. These types of algorithms (e.g., soft-tissue localization - STiL) were simulated by designing a discrimination task, which quantifies the differentiation of tissue textures, measured experimentally and fit as a power-law in trend (with exponent β) using a cohort of MV images of patient lungs. The modeled MTF and NPS were used to investigate the effect of

  3. Estimation of CT cone-beam geometry using a novel method insensitive to phantom fabrication inaccuracy: Implications for isocenter localization accuracy

    Science.gov (United States)

    Chetley Ford, J.; Zheng, Dandan; Williamson, Jeffrey F.

    2011-01-01

    Purpose: Mechanical instabilities that occur during gantry rotation of on-board cone-beam computed tomography (CBCT) imaging systems limit the efficacy of image-guided radiotherapy. Various methods for calibrating the CBCT geometry and correcting errors have been proposed, including some that utilize dedicated fiducial phantoms. The purpose of this work was to investigate the role of phantom fabrication imprecision on the accuracy of a particular CT cone-beam geometry estimate and to test a new method to mitigate errors in beam geometry arising from imperfectly fabricated phantoms. Methods: The authors implemented a fiducial phantom-based beam geometry estimation following the one described by Cho et al. [Med Phys 32(4), 968–983 (2005)]. The algorithm utilizes as input projection images of the phantom at various gantry angles and provides a full nine parameter beam geometry characterization of the source and detector position and detector orientation versus gantry angle. A method was developed for recalculating the beam geometry in a coordinate system with origin at the source trajectory center and aligned with the axis of gantry rotation, thus making the beam geometry estimation independent of the placement of the phantom. A second CBCT scan with the phantom rotated 180° about its long axis was averaged with the first scan to mitigate errors from phantom imprecision. Computer simulations were performed to assess the effect of 2D fiducial marker positional error on the projections due to image discretization, as well as 3D fiducial marker position error due to phantom fabrication imprecision. Experimental CBCT images of a fiducial phantom were obtained and the algorithm used to measure beam geometry for a Varian Trilogy with an on-board CBCT. Results: Both simulations and experimental results reveal large sinusoidal oscillations in the calculated beam geometry parameters with gantry angle due to displacement of the phantom from CBCT isocenter and misalignment

  4. Comparison of 2 root surface area measurement methods: 3-dimensional laser scanning and cone-beam computed tomography

    International Nuclear Information System (INIS)

    Tasanapanont, Jintana; Apisariyakul, Janya; Wattanachai, Tanapan; Jotikasthira, Dhirawat; Sriwilas, Patiyut; Midtboe, Marit

    2017-01-01

    The aim of this study was to compare the use of 3-dimensional (3D) laser scanning and cone-beam computed tomography (CBCT) as methods of root surface measurement. Thirty teeth (15 maxillary first premolars and 15 mandibular first premolars) from 8 patients who required extractions for orthodontic treatment were selected. Before extraction, pre-treatment CBCT images of all the patients were recorded. First, a CBCT image was imported into simulation software (Mimics version 15.01; Materialise, Leuven, Belgium) and the root surface area of each tooth was calculated using 3-Matic (version 7.01, Materialise, Leuven, Belgium). After extraction, all the teeth were scanned and the root surface area of each extracted tooth was calculated. The root surface areas calculated using these 2 measurement methods were analyzed using the paired t-test (P<.05). Correlations between the 2 methods were determined by calculating the Pearson correlation coefficient. The intraclass correlation coefficient (ICC) was used to assess intraobserver reliability. The root surface area measurements (230.11±41.97 mm 2 ) obtained using CBCT were slightly greater than those (229.31±42.46 mm2) obtained using 3D laser scanning, but not significantly (P=.425). A high Pearson correlation coefficient was found between the CBCT and the 3D laser scanner measurements. The intraobserver ICC was 1.000 for 3D laser scanning and 0.990 for CBCT. This study presents a novel CBCT approach for measuring the root surface area; this technique can be used for estimating the root surface area of non-extracted teeth

  5. Comparison of 2 root surface area measurement methods: 3-dimensional laser scanning and cone-beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Tasanapanont, Jintana; Apisariyakul, Janya; Wattanachai, Tanapan; Jotikasthira, Dhirawat [Dept. of Orthodontics and Pediatric Dentistry, Faculty of Dentistry, Chiang Mai University, Chiang Mai (Thailand); Sriwilas, Patiyut [Dept. of Radiology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok (Thailand); Midtboe, Marit [Dept. of Clinical Dentistry - Orthodontics, Faculty of Medicine and Dentistry, University of Bergen, Bergen (Norway)

    2017-06-15

    The aim of this study was to compare the use of 3-dimensional (3D) laser scanning and cone-beam computed tomography (CBCT) as methods of root surface measurement. Thirty teeth (15 maxillary first premolars and 15 mandibular first premolars) from 8 patients who required extractions for orthodontic treatment were selected. Before extraction, pre-treatment CBCT images of all the patients were recorded. First, a CBCT image was imported into simulation software (Mimics version 15.01; Materialise, Leuven, Belgium) and the root surface area of each tooth was calculated using 3-Matic (version 7.01, Materialise, Leuven, Belgium). After extraction, all the teeth were scanned and the root surface area of each extracted tooth was calculated. The root surface areas calculated using these 2 measurement methods were analyzed using the paired t-test (P<.05). Correlations between the 2 methods were determined by calculating the Pearson correlation coefficient. The intraclass correlation coefficient (ICC) was used to assess intraobserver reliability. The root surface area measurements (230.11±41.97 mm{sup 2}) obtained using CBCT were slightly greater than those (229.31±42.46 mm2) obtained using 3D laser scanning, but not significantly (P=.425). A high Pearson correlation coefficient was found between the CBCT and the 3D laser scanner measurements. The intraobserver ICC was 1.000 for 3D laser scanning and 0.990 for CBCT. This study presents a novel CBCT approach for measuring the root surface area; this technique can be used for estimating the root surface area of non-extracted teeth.

  6. Optimal design and fabrication method for antireflection coatings for P-polarized 193 nm laser beam at large angles of incidence (68°-74°).

    Science.gov (United States)

    Jin, Jingcheng; Jin, Chunshui; Li, Chun; Deng, Wenyuan; Chang, Yanhe

    2013-09-01

    Most of the optical axes in modern systems are bent for optomechanical considerations. Antireflection (AR) coatings for polarized light at oblique incidence are widely used in optical surfaces like prisms or multiform lenses to suppress undesirable reflections. The optimal design and fabrication method for AR coatings with large-angle range (68°-74°) for a P-polarized 193 nm laser beam is discussed in detail. Experimental results showed that after coating, the reflection loss of a P-polarized laser beam at large angles of incidence on the optical surfaces is reduced dramatically, which could greatly improve the output efficiency of the optical components in the deep ultraviolet vacuum range.

  7. Beam-beam diagnostics from closed-orbit distortion

    Energy Technology Data Exchange (ETDEWEB)

    Furman, M.; Chin, Y.H.; Eden, J. [Lawrence Berkeley Lab., CA (United States); Kozanecki, W. [DAPNIA/SPP, CEN Saclay Gif-sur-Yvette, (FR)]|[Stanford Linear Accelerator Center, Menlo Park, CA (United States); Tennyson, J.; Ziemann, V. [Stanford Linear Accelerator Center, Menlo Park, CA (United States)

    1992-07-01

    We study the applicability of beam-beam deflection techniques as a tuning tool for asymmetric B factories, focusing on PEP-II as an example. Assuming that the closed orbits of the two beams are separated vertically at the interaction point by a local orbit bump that is nominally closed, we calculate the residual beam orbit distortions due to the beam-beam interaction. Difference orbit measurements, performed at points conveniently distant from the interaction point (IP), provide distinct signatures that can be used to maintain the beams in collision and perform detailed optical diagnostics at the IP. A proposal to test this method experimentally at the TRISTAN ring is briefly discussed.

  8. Enhanced activity and interfacial durability study of ultra low Pt based electrocatalysts prepared by ion beam assisted deposition (IBAD) method

    International Nuclear Information System (INIS)

    Ramaswamy, N.; Arruda, T.M.; Wen, W.; Hakim, N.; Saha, M.; Gulla, A.; Mukerjee, S.

    2009-01-01

    Ultra low loading noble metal (0.04-0.12 mg Pt /cm 2 ) based electrodes were obtained by direct metallization of non-catalyzed gas diffusion layers via dual ion beam assisted deposition (IBAD) method. Fuel cell performance results reported earlier indicate significant improvements in terms of mass specific power density of 0.297 g Pt /kW with 250 A thick IBAD deposit (0.04 mg Pt /cm 2 for a total MEA loading of 0.08 mg Pt /cm 2 ) at 0.65 V in contrast to the state of the art power density of 1.18 g Pt /kW using 1 mg Pt(MEA) /cm 2 at 0.65 V. In this article we report the peroxide radical initiated attack of the membrane electrode assembly utilizing IBAD electrodes in comparison to commercially available E-TEK (now BASF Fuel Cell GmbH) electrodes and find the pathway of membrane degradation as well. A novel segmented fuel cell is used for this purpose to relate membrane degradation to peroxide generation at the electrode/electrolyte interface by means of systematic pre and post analyses of the membrane are presented. Also, we present the results of in situ X-ray absorption spectroscopy (XAS) experiments to elucidate the structure/property relationships of these electrodes that lead to superior performance in terms of gravimetric power density obtained during fuel cell operation.

  9. Clinical implementation of a GPU-based simplified Monte Carlo method for a treatment planning system of proton beam therapy.

    Science.gov (United States)

    Kohno, R; Hotta, K; Nishioka, S; Matsubara, K; Tansho, R; Suzuki, T

    2011-11-21

    We implemented the simplified Monte Carlo (SMC) method on graphics processing unit (GPU) architecture under the computer-unified device architecture platform developed by NVIDIA. The GPU-based SMC was clinically applied for four patients with head and neck, lung, or prostate cancer. The results were compared to those obtained by a traditional CPU-based SMC with respect to the computation time and discrepancy. In the CPU- and GPU-based SMC calculations, the estimated mean statistical errors of the calculated doses in the planning target volume region were within 0.5% rms. The dose distributions calculated by the GPU- and CPU-based SMCs were similar, within statistical errors. The GPU-based SMC showed 12.30-16.00 times faster performance than the CPU-based SMC. The computation time per beam arrangement using the GPU-based SMC for the clinical cases ranged 9-67 s. The results demonstrate the successful application of the GPU-based SMC to a clinical proton treatment planning.

  10. Focused beam reflectance method as an innovative (PAT) tool to monitor in-line granulation process in fluidized bed.

    Science.gov (United States)

    Alshihabi, Firas; Vandamme, Thierry; Betz, Gabriele

    2013-02-01

    Fluidized bed granulation is a commonly used unit operation in the pharmaceutical industry. But still to obtain and control the desired granule size is challenging due to many process variables affecting the final product. Focused beam reflectance measurement (FBRM, Mettler-Toledo, Switzerland) is an increasingly popular particle growth analysis technique. FBRM tool was installed in two different locations inside a fluidized bed granulator (GPCG2, Glatt, Binzen) in order to monitor the granulation growth kinetics. An experimental design was created to study the effect of process variables using FBRM probe and comparing the results with the one's measured by sieve analysis. The probe location is of major importance to get smooth and robust curves. The excess feeding of binder solution might lead to agglomeration and thus to process collapse, however this phenomenon was clearly detected with FBRM method. On the other hand, the process variables at certain levels might affect the FBRM efficiency by blocking the probe window with sticky particles. A good correlation was obtained (R(2) = 0.95) between FBRM and sieve analysis mean particle size. The proposed in-line monitoring tool enables the operator to select appropriate process parameters and control the wet granulation process more efficiently.

  11. Coherent beam-beam effects

    International Nuclear Information System (INIS)

    Chao, A.W.

    1992-01-01

    There are two physical pictures that describe the beam-beam interaction in a storage ring collider: The weak-strong and the strong-strong pictures. Both pictures play a role in determining the beam-beam behavior. This review addresses only the strong-strong picture. The corresponding beam dynamical effects are referred to as the coherent beam-beam effects. Some basic knowledge of the weak-strong picture is assumed. To be specific, two beams of opposite charges are considered. (orig.)

  12. An improvement of a beam search method for warehouse storage allocation planning problems minimizing the number of operations and the aggregated number of products for each customer

    Science.gov (United States)

    Nishi, Tatsushi; Yamamoto, Shinichiro; Konishi, Masami

    The storage allocation planning problem in warehouse management is to determine the allocation of products to the storage space and intermediate operations for retrieving products so as to minimize the number of operations, and maximize the collected number of products for each customer when the sequence of requests for inlet and retrieval operations are given. In this paper, we propose an efficient beam search method for generating a near optimal solution with a reasonable computation time. A heuristic procedure is also proposed in order to reduce a search space in the beam search method by using the information of subsequent inlet and retrieving requests. The validity of the proposed method is confirmed by comparing the results with the optimal solution derived by solving an MILP problem. The effectiveness of the proposed method is demonstrated by solving an actual large-sized problem consisting of more than 3000 operations.

  13. An Approximate Treatment of Reflection Coefficient in the Phased Beam Tracing Method for the Simulation of Enclosed Sound Fields at Medium Frequencies

    DEFF Research Database (Denmark)

    Jeong, Cheol-Ho; Ih, Jeong-Guon; Rindel, Jens Holger

    2008-01-01

    The phased beam tracing method (PBTM) was suggested as a medium-frequency simulation technique for the calculation of impulse response, although main assumptions of geometric acoustics still hold. The phased method needs the reflection coefficient for characterizing the acoustic property of a sur......The phased beam tracing method (PBTM) was suggested as a medium-frequency simulation technique for the calculation of impulse response, although main assumptions of geometric acoustics still hold. The phased method needs the reflection coefficient for characterizing the acoustic property...... of a surface and the complex wave number for describing the propagation characteristics. In this study, two types of approximate real reflection coefficients derived from the measured absorption coefficient were tested for a practical applicability. As a test example, pressure impulse responses and energy...

  14. Testing of full-size reinforced concrete beams strengthened with FRP composites : experimental results and design methods verification(appendices)

    Science.gov (United States)

    2000-06-01

    In 1997, a load rating of an historic reinforced concrete bridge in Oregon, Horsetail Creek Bridge, indicated substandard shear and moment capacities of the beams. As a result, the Bridge was strengthened with fiber reinforced polymer composites as a...

  15. Testing of full-size reinforced concrete beams strengthened with FRP composites : experimental results and design methods verification

    Science.gov (United States)

    2000-06-01

    In 1997, a load rating of an historic reinforced concrete bridge in Oregon, Horsetail Creek Bridge, indicated substandard shear and moment capacities of the beams. As a result, the Bridge was strengthened with fiber reinforced : polymer composites as...

  16. Laser beam shaping optical system design methods and their application in edge-emitting semiconductor laser-based LIDAR systems

    Science.gov (United States)

    Serkan, Mert

    LIDAR (Light Detection And Ranging) systems are employed for numerous applications such as remote sensing, military applications, optical data storage, display technology, and material processing. Furthermore, they are superior to other active remote sensing tools such as RADAR systems, considering their higher accuracy and more precise resolution due to their much shorter wavelengths and narrower beamwidth. Several types of lasers can be utilized as the radiation source of several LIDAR systems. Semiconductor laser-based LIDAR systems have several advantages such as low cost, compactness, broad range of wavelengths, and high PRFs (Pulse Repetition Frequency). However, semiconductor lasers have different origins and angles of divergence in the two transverse directions, resulting in the inherent astigmatism and elliptical beam shape. Specifically, elliptical beam shape is not desirable for several laser-based applications including LIDAR systems specifically designed to operate in the far-field region. In this dissertation, two mirror-based and two lens-based beam shapers are designed to circularize, collimate, and expand an edge-emitting semiconductor laser beam to a desired beam diameter for possible application in LIDAR systems. Additionally, most laser beams including semiconductor laser beams have Gaussian irradiance distribution. For applications that require uniform illumination of an extended target area, Gaussian irradiance distribution is undesirable. Therefore, a specific beam shaper is designed to transform the irradiance distribution from Gaussian to uniform in addition to circularizing, collimating, and expanding the semiconductor laser beam. For the design of beam shapers, aperture sizes of the surfaces are preset for desired power transmission and allowed diffraction level, surface parameters of the optical components and the distances between these surfaces are determined. Design equations specific to these beam shaping optical systems are

  17. Titanium dioxide fine structures by RF magnetron sputter method deposited on an electron-beam resist mask

    Science.gov (United States)

    Hashiba, Hideomi; Miyazaki, Yuta; Matsushita, Sachiko

    2013-09-01

    Titanium dioxide (TiO2) has been draw attention for wide range of applications from photonic crystals for visible light range by its catalytic characteristics to tera-hertz range by its high refractive index. We present an experimental study of fabrication of fine structures of TiO2 with a ZEP electron beam resist mask followed by Ti sputter deposition techniques. A TiO2 thin layer of 150 nm thick was grown on an FTO glass substrate with a fine patterned ZEP resist mask by a conventional RF magnetron sputter method with Ti target. The deposition was carried out with argon-oxygen gases at a pressure of 5.0 x 10 -1 Pa in a chamber. During the deposition, ratio of Ar-O2 gas was kept to the ratio of 2:1 and the deposition ratio was around 0.5 Å/s to ensure enough oxygen to form TiO2 and low temperature to avoid deformation of fine pattern of the ZPU resist mask. Deposited TiO2 layers are white-transparent, amorphous, and those roughnesses are around 7 nm. Fabricated TiO2 PCs have wider TiO2 slabs of 112 nm width leaving periodic 410 x 410 nm2 air gaps. We also studied transformation of TiO2 layers and TiO2 fine structures by baking at 500 °C. XRD measurement for TiO2 shows that the amorphous TiO2 transforms to rutile and anatase forms by the baking while keeping the same profile of the fine structures. Our fabrication method can be one of a promising technique to optic devices on researches and industrial area.

  18. Superresolution beams

    CSIR Research Space (South Africa)

    Ngcobo, S

    2011-11-01

    Full Text Available zones capable of introducing a phase shift of zero or p on the alternately out of phase rings of the TEMp0 beams into a unified phase and then focusing the rectified beam to generate a high resolution beam which has a Gaussian beam intensity distribution...

  19. Generic method for automatic bladder segmentation on cone beam CT using a patient-specific bladder shape model

    International Nuclear Information System (INIS)

    Schoot, A. J. A. J. van de; Schooneveldt, G.; Wognum, S.; Stalpers, L. J. A.; Rasch, C. R. N.; Bel, A.; Hoogeman, M. S.; Chai, X.

    2014-01-01

    Purpose: The aim of this study is to develop and validate a generic method for automatic bladder segmentation on cone beam computed tomography (CBCT), independent of gender and treatment position (prone or supine), using only pretreatment imaging data. Methods: Data of 20 patients, treated for tumors in the pelvic region with the entire bladder visible on CT and CBCT, were divided into four equally sized groups based on gender and treatment position. The full and empty bladder contour, that can be acquired with pretreatment CT imaging, were used to generate a patient-specific bladder shape model. This model was used to guide the segmentation process on CBCT. To obtain the bladder segmentation, the reference bladder contour was deformed iteratively by maximizing the cross-correlation between directional grey value gradients over the reference and CBCT bladder edge. To overcome incorrect segmentations caused by CBCT image artifacts, automatic adaptations were implemented. Moreover, locally incorrect segmentations could be adapted manually. After each adapted segmentation, the bladder shape model was expanded and new shape patterns were calculated for following segmentations. All available CBCTs were used to validate the segmentation algorithm. The bladder segmentations were validated by comparison with the manual delineations and the segmentation performance was quantified using the Dice similarity coefficient (DSC), surface distance error (SDE) and SD of contour-to-contour distances. Also, bladder volumes obtained by manual delineations and segmentations were compared using a Bland-Altman error analysis. Results: The mean DSC, mean SDE, and mean SD of contour-to-contour distances between segmentations and manual delineations were 0.87, 0.27 cm and 0.22 cm (female, prone), 0.85, 0.28 cm and 0.22 cm (female, supine), 0.89, 0.21 cm and 0.17 cm (male, supine) and 0.88, 0.23 cm and 0.17 cm (male, prone), respectively. Manual local adaptations improved the segmentation

  20. The development of a postal method to assess X-ray beam parameters and image quality in dental radiology

    International Nuclear Information System (INIS)

    Fenton, D.M.

    1994-10-01

    Intraoral radiographs are an extremely valuable diagnostic tool in dentistry. Radiography permits the early detection and diagnosis of dental disease and consequently is used extensively. However, public concern about radiation exposure has increased in recent times. This concern is reflected in national and international law, to the extent that, the basic principles of radiological protection, that is, justification, optimisation and dose limitation are written into law. Furthermore, in Ireland, the regulations, as outlined in the Code of Practice for Radiological Protection in Dentistry, require intraoral dental X-ray machines to perform to certain standards. A report of a direct survey of 164 intraoral dental X-ray machines is given in this study. The survey covered mechanical, electrical as well as radiation safety. Inadequacies with respect to focus to skin distance and timer accuracy were found in 45% and 42% of the machines surveyed. Ninety eight machines were assessed for electrical safety in which 48% were found to be unsafe. The results indicate that a complete assessment of the performance of dental X-ray units in Ireland is required. However, as there are in excess of 800 dental X-ray machines located throughout the country, such an assessment would be very costly for the regulatory authority. The development of a postal method for the assessment of the performance of dental X-ray machines is described in this study. This postal method provides information on the kV, total filtration, beam width and timer linearity and is undertaken by means of a penetrameter and film envelopes for exposure to the X-ray set under examination, together with a questionnaire that requests information on environment in which the machine is located. Using this method an accuracy of +-5% of the actual value was achieved in the measurement of kVp. The penetrameter was also used to assess whether or not the filtration of a particular machine complies with the regulations. This