WorldWideScience

Sample records for baseline blood glucose

  1. Gcg-XTEN: an improved glucagon capable of preventing hypoglycemia without increasing baseline blood glucose.

    Directory of Open Access Journals (Sweden)

    Nathan C Geething

    Full Text Available OBJECTIVE: While the majority of current diabetes treatments focus on reducing blood glucose levels, hypoglycemia represents a significant risk associated with insulin treatment. Glucagon plays a major regulatory role in controlling hypoglycemia in vivo, but its short half-life and hyperglycemic effects prevent its therapeutic use for non-acute applications. The goal of this study was to identify a modified form of glucagon suitable for prophylactic treatment of hypoglycemia without increasing baseline blood glucose levels. METHODOLOGY/PRINCIPAL FINDINGS: Through application of the XTEN technology, we report the construction of a glucagon fusion protein with an extended exposure profile (Gcg-XTEN. The in vivo half-life of the construct was tuned to support nightly dosing through design and testing in cynomolgus monkeys. Efficacy of the construct was assessed in beagle dogs using an insulin challenge to induce hypoglycemia. Dose ranging of Gcg-XTEN in fasted beagle dogs demonstrated that the compound was biologically active with a pharmacodynamic profile consistent with the designed half-life. Prophylactic administration of 0.6 nmol/kg Gcg-XTEN to dogs conferred resistance to a hypoglycemic challenge at 6 hours post-dose without affecting baseline blood glucose levels. Consistent with the designed pharmacokinetic profile, hypoglycemia resistance was not observed at 12 hours post-dose. Importantly, the solubility and stability of the glucagon peptide were also significantly improved by fusion to XTEN. CONCLUSIONS/SIGNIFICANCE: The data show that Gcg-XTEN is effective in preventing hypoglycemia without the associated hyperglycemia expected for unmodified glucagon. While the plasma clearance of this Gcg-XTEN has been optimized for overnight dosing, specifically for the treatment of nocturnal hypoglycemia, constructs with significantly longer exposure profiles are feasible. Such constructs may have multiple applications such as allowing for more

  2. Low Blood Glucose (Hypoglycemia)

    Science.gov (United States)

    ... Other Dental Problems Diabetic Eye Disease Low Blood Glucose (Hypoglycemia) What is hypoglycemia? Hypoglycemia, also called low ... actions can also help prevent hypoglycemia: Check blood glucose levels Knowing your blood glucose level can help ...

  3. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools To Know Your Risk Alert Day ... DKA (Ketoacidosis) & Ketones Kidney Disease (Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose Testing ...

  4. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... symptoms include the following: High blood glucose High levels of sugar in the urine Frequent urination Increased ... you should check and what your blood glucose levels should be. Checking your blood and then treating ...

  5. Blood Test: Glucose

    Science.gov (United States)

    ... Things to Know About Zika & Pregnancy Blood Test: Glucose KidsHealth > For Parents > Blood Test: Glucose Print A A A Text Size What's in ... de sangre: glucosa What It Is A blood glucose test measures the amount of glucose (the main ...

  6. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... how often you should check and what your blood glucose levels should be. Checking your blood and then treating ... I Treat Hyperglycemia? You can often lower your blood glucose level by exercising. However, if your blood glucose is ...

  7. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... and eAG Hypoglycemia (Low blood glucose) Hyperglycemia (High blood glucose) Dawn Phenomenon Checking for Ketones Tight Diabetes Control donate en -- Diabetes Must Be Stopped - 2016-06-donation- ...

  8. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Health Step On Up Treatment & Care Blood Glucose Testing Medication Doctors, Nurses & More Oral Health & Hygiene Women ... Living With Diabetes > Treatment and Care > Blood Glucose Testing Share: Print Page Text Size: A A A ...

  9. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... by Mail Close www.diabetes.org > Living With Diabetes > Treatment and Care > Blood Glucose Testing Share: Print Page Text Size: ... and-how-tos, In this section Living With Diabetes Treatment and Care Blood Glucose Testing Checking Your Blood Glucose A1C ...

  10. Hyperglycemia (High Blood Glucose)

    Science.gov (United States)

    ... by Mail Close www.diabetes.org > Living With Diabetes > Treatment and Care > Blood Glucose Testing Share: Print Page Text Size: ... and-how-tos, In this section Living With Diabetes Treatment and Care Blood Glucose Testing Checking Your Blood Glucose A1C ...

  11. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... but it is not as effective as it should be. You ate more than planned or exercised ... glucose often. Ask your doctor how often you should check and what your blood glucose levels should ...

  12. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Complications DKA (Ketoacidosis) & Ketones Kidney Disease (Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose ... glucose) Dawn Phenomenon Checking for Ketones Tight Diabetes Control donate en -- Your Gift for Research Doubled - 2016- ...

  13. Monitor blood glucose - slideshow

    Science.gov (United States)

    ... medlineplus.gov/ency/presentations/100220.htm Monitoring blood glucose - Series—Monitoring blood glucose: Using a self-test meter To use the ... A.M. Editorial team. Related MedlinePlus Health Topics Blood Sugar A.D.A.M., Inc. is accredited by ...

  14. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... by Mail Close www.diabetes.org > Living With Diabetes > Treatment and Care > Blood Glucose Testing Share: Print Page ... and-how-tos, In this section Living With Diabetes Treatment and Care Blood Glucose Testing Checking Your Blood ...

  15. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose Testing Medication Doctors, Nurses & More Oral Health & Hygiene Women A1C Insulin Pregnancy ...

  16. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Disease (Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose Testing Medication Doctors, Nurses & More Oral Health & Hygiene Women A1C Insulin ...

  17. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools To Know Your Risk Alert Day Diabetes Basics Home Symptoms Diagnosis America's Diabetes Challenge Type 1 Type 2 Facts About Type 2 Enroll ...

  18. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools To ... Index Low-Calorie Sweeteners Sugar and Desserts Fitness Exercise & Type 1 Diabetes Get Started Safely Get And ...

  19. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... today can fund critical diabetes research and support vital diabetes education services that improve the ... of Hyperglycemia? The signs and symptoms include the following: High blood glucose ...

  20. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... today can fund critical diabetes research and support vital diabetes education services that improve the lives of ... m.). What are the Symptoms of Hyperglycemia? The signs and symptoms include the following: High blood glucose ...

  1. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... On Up Treatment & Care Blood Glucose Testing Medication Doctors, Nurses & More Oral Health & Hygiene Women A1C Insulin ... Diabetes Pro: Professional Resources Online We Support Your Doctor Clinical Practice Guidelines Patient Education Materials Scientific Sessions ...

  2. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... avoid problems associated with hyperglycemia. How Do I Treat Hyperglycemia? You can often lower your blood glucose ... be a serious problem if you don't treat it, so it's important to treat as soon ...

  3. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Up Treatment & Care Blood Glucose Testing Medication Doctors, Nurses & More Oral Health & Hygiene Women A1C Insulin Pregnancy ... for Professionals Professional Books Patient Access to Research Student Resources History of Diabetes Resources for School Projects ...

  4. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose Testing Medication Doctors, Nurses & More Oral ... 2 Diabetes Know Your Rights Employment Discrimination Health Care Professionals Law Enforcement Driver's License For Lawyers Food & ...

  5. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose Testing Medication Doctors, Nurses & More Oral Health & Hygiene Women A1C Insulin Pregnancy 8 Tips for Caregivers ...

  6. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Care Blood Glucose Testing Medication Doctors, Nurses & More Oral ... someone new is diagnosed. Diabetes causes more deaths a year than breast cancer and AIDS combined. Your gift today will help ...

  7. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Hispanic Heritage Month African American Programs Latino Programs Asian Americans, Native Hawaiians and Pacific Islanders American Indian/ ... High blood glucose happens when the body has too little insulin or when the body can't ...

  8. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Disease (Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose Testing Medication Doctors, Nurses & More ... us get closer to curing diabetes and better treatments for those living with diabetes. Other Ways to ...

  9. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Complications DKA (Ketoacidosis) & Ketones Kidney Disease (Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose ... Find Your Local Office Find your local diabetes education program Calendar of Events Wellness Lives Here Drive ...

  10. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... the urine Frequent urination Increased thirst Part of managing your diabetes is checking your blood glucose often. ... Blog Online Community Site Menu Are You at Risk? Diagnosis Lower Your Risk Risk Test Alert Day ...

  11. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... the urine Frequent urination Increased thirst Part of managing your diabetes is checking your blood glucose often. ... events, such as eating breakfast, take on exaggerated importance. It's a world where a person needs a ...

  12. Human blood glucose dynamics

    OpenAIRE

    Rahaghi, Farbod N.

    2007-01-01

    The control of blood glucose concentration has become central to the prevention of morbidity in diabetes. Currently sensors are becoming available to make available near continuous measurements of tissue glucose concentrations. Frequently measured values provide an opportunity to analyze the dynamics of these measurements in addition to statistical analysis. The dynamics can be used to verify sensor validity, to provide a physiologic control target, and serve as a tool to diagnose and monitor...

  13. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... In Memory In Honor Become a Member En Español Type 1 Type 2 About Us Online Community ... Page Text Size: A A A Listen En Español Hyperglycemia (High Blood Glucose) Hyperglycemia is the technical ...

  14. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... produces daily around 4:00 a.m. to 5:00 a.m.). What are the Symptoms of Hyperglycemia? The signs and symptoms include the following: High blood glucose High levels of sugar in the urine Frequent urination Increased ...

  15. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Complications DKA (Ketoacidosis) & Ketones Kidney Disease (Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose Testing ... html Learn More Join Ryan Reed & Drive Your Health Access tools to help actively manage your diabetes. ... .survey-alert-wrap').remove(); if (data.submitSurveyResponse.success == 'false') { $('.survey-form'). ...

  16. Blood glucose monitoring.

    Science.gov (United States)

    Davey, Sarah

    2014-06-10

    I found the CPD article on blood glucose monitoring and management in acute stroke care interesting and informative. As I am a mental health nursing student, my knowledge of chronic physical conditions is limited, so I learned a lot. PMID:24894257

  17. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Size: A A A Listen En Español Hyperglycemia (High Blood Glucose) Hyperglycemia is the technical term for ... diabetes. Learn More: Stories of Courage, Love and Resilience - 2016-08-blog.html Learn More Stories of ...

  18. How to monitor blood glucose.

    Science.gov (United States)

    Dunning, Trisha

    2016-01-27

    Rationale and key points Capillary blood glucose monitoring is an essential component of diabetes care. Blood glucose tests provide important information about how the body is controlling blood glucose metabolism, and the effect of glucose-lowering medicines, illness and stress. ▶ The nurse should consider the rationale for testing blood glucose each time they perform a test, and reflect on the result, taking into consideration the patient's blood glucose target range and recommended care guidelines. ▶ Blood glucose testing times and testing frequency should be planned to suit the glucose-lowering medicine regimen and the clinical situation. Reflective activity Clinical skills articles can help update your practice and ensure it remains evidence based. Apply this article to your practice. Reflect on and write a short account of: 1. What you have gained from this article. 2. How this article will influence your practice when monitoring blood glucose. Subscribers can upload their reflective accounts at: rcni.com/portfolio . PMID:26967884

  19. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... little insulin or when the body can't use insulin properly. What Causes Hyperglycemia? A number of ... enough insulin. Without insulin, your body can't use glucose for fuel, so your body breaks down ...

  20. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Us in the Fight for a Cure Your tax-deductible gift today can fund critical diabetes research ... t use glucose for fuel, so your body breaks down fats to use for energy. When your ...

  1. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Doctors, Nurses & More Oral Health & Hygiene Women A1C Insulin Pregnancy 8 Tips for Caregivers Health Insurance Health ... glucose happens when the body has too little insulin or when the body can't use insulin ...

  2. Blood Glucose Monitoring Devices

    Science.gov (United States)

    ... Glucose NIH Medline Plus - Diabetes Spotlight FDA permits marketing of first system of mobile medical apps for ... feeds Follow FDA on Twitter Follow FDA on Facebook View FDA videos on YouTube View FDA photos ...

  3. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... critical diabetes research and support vital diabetes education services that improve the lives of those with diabetes. $ ... glucose level. Cutting down on the amount of food you eat might also help. Work with your ...

  4. Blood glucose in acute stroke

    DEFF Research Database (Denmark)

    Olsen, Tom Skyhøj

    2009-01-01

    Blood glucose is often elevated in acute stroke, and higher admission glucose levels are associated with larger lesions, greater mortality and poorer functional outcome. In patients treated with thrombolysis, hyperglycemia is associated with an increased risk of hemorrhagic transformation of...... infarcts. For a number of years, tight glycemic control has been regarded as beneficial in critically illness, but recent research has been unable to support this notion. The only completed randomized study on glucose-lowering therapy in stroke has failed to demonstrate effect, and concerns relating to the...... risk of inducing potentially harmful hypoglycemia has been raised. Still, basic and observational research is overwhelmingly in support of a causal relationship between blood glucose and stroke outcome and further research on glucose-lowering therapy in acute stroke is highly warranted....

  5. Is Low Blood Glucose (Hypoglycemia) Dangerous?

    Science.gov (United States)

    ... Diabetes Sign Up forJoslin Newsletters Is Low Blood Glucose (Hypoglycemia) Dangerous? Low blood glucose or hypoglycemia is one of the most common ... In general, hypoglycemia is defined as a blood glucose level below 70 mg/dl. Low blood glucose ...

  6. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Type 2 Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High ... Diabetes Meal Plans Create Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart- ...

  7. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Type 2 Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High ... the Guesswork out of Planning Meals! Find the healthy eating plan that works for you and your diabetes. ...

  8. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Student Resources History of Diabetes Resources for School Projects How to Reference Our Site Diabetes Basics Myths ... blood, which can lead to ketoacidosis. Ketoacidosis is life-threatening and needs immediate treatment. Symptoms include: Shortness ...

  9. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... you avoid problems associated with hyperglycemia. How Do I Treat Hyperglycemia? You can often lower your blood ... record for use in an emergency. How Can I Prevent Hyperglycemia? Your best bet is to practice ...

  10. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Professional Books Patient Access to Research Student Resources History of Diabetes Resources for School Projects How to ... blood, which can lead to ketoacidosis. Ketoacidosis is life-threatening and needs immediate treatment. Symptoms include: Shortness ...

  11. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... 2 Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High ... Complications Neuropathy Foot Complications DKA (Ketoacidosis) & Ketones Kidney Disease (Nephropathy) Gastroparesis Mental Health Step On Up Treatment & ...

  12. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... 2 Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High ... What Can I Drink? Fruit Dairy Food Tips Eating Out Quick Meal Ideas Snacks Nutrient Content Claims ...

  13. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... and-a1c-hyperglycemia,tips-and-how-tos, In this section Living With Diabetes Treatment and Care Blood ... ensureArray(data.submitSurveyResponse.errors); $.each(surveyErrors, function () { if (this.errorField) { $('input[name="' + this.errorField + '"]').closest('.form-group') . ...

  14. Breakfast, blood glucose, and cognition.

    Science.gov (United States)

    Benton, D; Parker, P Y

    1998-04-01

    This article compares the findings of three studies that explored the role of increased blood glucose in improving memory function for subjects who ate breakfast. An initial improvement in memory function for these subjects was found to correlate with blood glucose concentrations. In subsequent studies, morning fasting was found to adversely affect the ability to recall a word list and a story read aloud, as well as recall items while counting backwards. Failure to eat breakfast did not affect performance on an intelligence test. It was concluded that breakfast consumption preferentially influences tasks requiring aspects of memory. In the case of both word list recall and memory while counting backwards, the decline in performance associated with not eating breakfast was reversed by the consumption of a glucose-supplemented drink. Although a morning fast also affected the ability to recall a story read aloud, the glucose drink did not reverse this decline. It appears that breakfast consumption influences cognition via several mechanisms, including an increase in blood glucose. PMID:9537627

  15. What is a normal blood glucose?

    Science.gov (United States)

    Güemes, Maria; Rahman, Sofia A; Hussain, Khalid

    2016-06-01

    Glucose is the key metabolic substrate for tissue energy production. In the perinatal period the mother supplies glucose to the fetus and for most of the gestational period the normal lower limit of fetal glucose concentration is around 3 mmol/L. Just after birth, for the first few hours of life in a normal term neonate appropriate for gestational age, blood glucose levels can range between 1.4 mmol/L and 6.2 mmol/L but by about 72 h of age fasting blood glucose levels reach normal infant, child and adult values (3.5-5.5 mmol/L). Normal blood glucose levels are maintained within this narrow range by factors which control glucose production and glucose utilisation. The key hormones which regulate glucose homoeostasis include insulin, glucagon, epinephrine, norepinephrine, cortisol and growth hormone. Pathological states that affect either glucose production or utilisation will lead to hypoglycaemia. Although hypoglycaemia is a common biochemical finding in children (especially in the newborn) it is not possible to define by a single (or a range of) blood glucose value/s. It can be defined as the concentration of glucose in the blood or plasma at which the individual demonstrates a unique response to the abnormal milieu caused by the inadequate delivery of glucose to a target organ (eg, the brain). Hypoglycaemia should therefore be considered as a continuum and the blood glucose level should be interpreted within the clinical scenario and with respect to the counter-regulatory hormonal responses and intermediate metabolites. PMID:26369574

  16. Prediction Methods for Blood Glucose Concentration

    DEFF Research Database (Denmark)

    Freckmann et al. discusses performance metrics used to characterize the accuracy of continuous glucose measurement devices. This topic is highly relevant for prediction models since many of them rely on the data given by the continuous sensors which are previously calibrated with blood glucose meter...... on the net effect of meals on the blood glucose concentration. By assuming that all major unexplained glycemic excursions can be vi Preface attributed to oral glucose ingestion, a meal vector is estimated which significantly improves the mathematical model. Results are shown on three patients during...... intrasubject variability by using the concept of interval pre-dictions. Instead of predicting a single blood glucose value in the future, a whole solution envelope is determined. With the presented theory it can be guaranteed that the real value is always inside of the envelope and moreover the envelope...

  17. Blood glucose response to pea fiber

    DEFF Research Database (Denmark)

    Hamberg, O; Rumessen, J J; Gudmand-Høyer, E

    1989-01-01

    Two new fiber types, pea fiber (PF) and sugar beet fiber (BF), were compared with wheat bran (WB) to investigate the effect on postprandial blood glucose and serum insulin responses in normal subjects. The control meal consisted of 150 g ground beef mixed with 50 g glucose and 20 g lactulose. Only...... addition of PF (15 g pure fiber) reduced the area under the incremental blood glucose curve significantly (by 65%, p less than 0.05). None of the fibers affected the area under the insulin-response curve significantly although it was reduced by all fibers. Mouth-to-cecum transit time, assessed by the...

  18. Non-Invasive Optical Blood Glucose Measurement

    Directory of Open Access Journals (Sweden)

    Megha C.Pande

    2013-07-01

    Full Text Available The method for noninvasively blood glucose monitoring system is discussed in this paper. Lot of research work has been done in developing the device which is completely noninvasive to avoid the pros & cons because of frequent pricking. In this paper we are trying to analyze the noninvasive blood glucose measurement study in the near infrared region which is the most suitable region for blood glucose measurement. For this purpose we use a technique which is similar to pulseoximetry based on near infrared spectrometry .An infrared light of particular wavelength is passed through fingertip containing an arterial pulse component are derived,thus minimizing influences of basal components such as resting blood volume,skin, muscle and bone.

  19. Recent developments in blood glucose sensors

    Directory of Open Access Journals (Sweden)

    Hui-Chen Wang

    2015-06-01

    Full Text Available Diabetes has recently become a leading cause of death worldwide. To date, although there is no means to cure or prevent diabetes, appropriate medication and blood sugar monitoring can enhance treatment efficiency, alleviate the symptoms, and diminish the complications of the condition. This review article deals with current growth areas in the market for blood glucose sensors and possible future alternatives, which are generally considered to be the point sample test and the continuous glucose monitor (CGM. Most glucose sensors are enzyme-based, whereas others are enzyme-free. The former class is sensitive and some products are extensively employed for daily self-sensing and in hospital environments as reliable diagnostic tools. The latter class, particularly the boronic acid fluorescent sensor, is facile and extremely promising. Practicality demands that all types of sensors offer accuracy, specificity, and real-time detection.

  20. Random blood glucose testing in dental practice

    DEFF Research Database (Denmark)

    Barasch, Andrei; Safford, Monika M; Qvist, Vibeke;

    2012-01-01

    The prevalence of diabetes mellitus (DM) has been increasing. Instances of patients' not having received a diagnosis have been reported widely, as have instances of poor control of DM or prediabetes among patient's who have the disease. These facts indicate that blood glucose screening is needed....

  1. Blood glucose and nocturnal blood pressure in African and caucasian men: the SABPA study

    OpenAIRE

    Lammertyn, Leandi; Schutte, Aletta Elisabeth; Schutte, Rudolph

    2011-01-01

    To investigate the relationship between nocturnal blood pressure and chronically elevated blood glucose to determine if these elevated blood glucose concentrations contribute to a non-dipping blood pressure, especially in high-risk groups such as Africans.

  2. Blood glucose control and monitoring in the critically ill

    NARCIS (Netherlands)

    R.T.M. van Hooijdonk

    2015-01-01

    This thesis deals with blood glucose control and blood glucose monitoring in intensive care unit (ICU) patients: two important aspects of care for and monitoring of critically ill patients. While the precise targets of blood glucose control in ICU patients remain a matter of debate, currently many,

  3. Blood Glucose Measurement Using Bioimpedance Technique

    OpenAIRE

    Kamat, D. K.; Dhanashri Bagul; Patil, P. M.

    2014-01-01

    Bioimpedance measurement is gaining importance in wide field of bioresearch and biomedical systems due to its noninvasive nature. Noninvasive measurement method is very important to decrease infection and physical injuries which result due to invasive measurement. This paper presents basic principle of bioimpedance along with its application for blood glucose analysis and effect of frequency on impedance measurement. Input from bioimpedance sensor is given to amplifier and signal conditioner ...

  4. Prediction Methods for Blood Glucose Concentration

    DEFF Research Database (Denmark)

    “Meta-Learning Based Blood Glucose Predictor for DiabeticSmartphone App” by Valeriya Naumova et al. demonstrates how a highly sophisticated glucose prediction model can be ported from a development language running on a PC to a format such that it can be used conveniently by the patients. A unique...... Continuous EEG Monitoring” by Claus Borg Juhl et al. shows how to use EEG signals to predict upcoming hypoglycemic situations in real-time by employing artificial neural networks. The results of a 30-day long clinical study with the implanted device and the developed algorithm are presented. The chapter......-Based Linear Multistep Predictors” by Marzia Cescon et al. uses data-based methods to develop individualized prediction models. The model can be considered as a combination of physiological models to precompute the rate of appearance of injected insulin and ingested carbohydrates in the bloodstream and of data...

  5. Blood Glucose Measurement Using Bioimpedance Technique

    Directory of Open Access Journals (Sweden)

    D. K. Kamat

    2014-01-01

    Full Text Available Bioimpedance measurement is gaining importance in wide field of bioresearch and biomedical systems due to its noninvasive nature. Noninvasive measurement method is very important to decrease infection and physical injuries which result due to invasive measurement. This paper presents basic principle of bioimpedance along with its application for blood glucose analysis and effect of frequency on impedance measurement. Input from bioimpedance sensor is given to amplifier and signal conditioner AD5933. AD5933 is then interfaced with microcontroller LPC1768 using I2C bus for displaying reading on LCD. Results can also be stored in database using UART interface of LPC1768.

  6. Intraoperative blood glucose levels in neurosurgical patients : an evaluation of two fluid regimens.

    Directory of Open Access Journals (Sweden)

    Swamy M

    2001-10-01

    Full Text Available Based on the evidence that hyperglycaemia aggravates ischaemic cerebral injury, it has been suggested that blood glucose levels be kept within 200 mg/dL during intracranial neurosurgery. Hypoglycaemia, however, can be a serious problem if glucose-containing solutions are avoided during the first four hours, as suggested in some studies. In order to explore the possibility of administering glucose in moderation so that the blood glucose levels are within acceptable limits, but at the same time the risk of hyoglycaemia is eliminated, we compared two intraoperative fluid regimens. Of the 52 neurosurgical patients studied, 32 patients received alternately 500 ml of 5% dextrose in normal saline and Ringer′s lactate (DNS/RL Group and 18 patients received alternately 500 ml of Ringer′s lactate and normal saline (RL/NS Group. Blood glucose concentrations were determined at the end of each unit of fluid, until the patient received 4 units of fluid. In the DNS/RL group, blood glucose values peaked with the administration of each unit of DNS and tended to return towards the baseline with the subsequent RL, but remained higher than the previous control value. In the RL/NS group, there was a progressive increase in blood glucose values throughout the study period, but the increase was not statistically significant. The blood glucose levels were significantly different between the two groups after each unit of fluid except at the end of the fourth unit. Two patients in the RL/NS group had hypoglycaemia. In conclusion, the DNS/RL regimen maintains blood glucose levels within acceptable limits while avoiding the risk of hyperglycaemia. Withholding glucose completely, lowers blood glucose levels, but carries a risk of hypoglycaemia in some patients.

  7. The effects of food deprivation and incentive motivation on blood glucose levels and cognitive function.

    Science.gov (United States)

    Green, M W; Elliman, N A; Rogers, P J

    1997-11-01

    The current study investigated the relationships between blood glucose levels, mild food deprivation, sympathetic arousal, and cognitive processing efficiency. Subjects (n = 82) were randomly assigned to four experimental conditions, comprising combined manipulations of food deprivation and incentive motivation. Baseline and mid-session measurements of blood glucose, blood pressure and pulse rate were taken. Subjects completed a number of measures of cognitive processing efficiency and self report measures of affective and somatic state. Although glucose levels were lowered following food deprivation, there was no significant detrimental effect of food deprivation on task performance. However, improved recognition memory processing times were associated with deprivation. Incentive motivation was associated with faster simple reaction times and higher diastolic blood pressure. There were no significant relationships between glucose levels and task performance, further supporting the hypothesis that the brain is relatively invulnerable to short food deprivation. PMID:9399371

  8. Blood flow is an important determinant of forearm glucose uptake following a mixed meal.

    Science.gov (United States)

    Fugmann, A; Sarabi, M; Karlström, B; Berne, C; Lithell, H; Lind, L

    2003-09-01

    Insulin-mediated vasodilation has been suggested to be of importance for glucose uptake during normoglycemic hyperinsulinemia. If this also is valid after an ordinary mixed meal remains to be evaluated. Forearm blood flow (FBF) and forearm glucose uptake change (evaluated by venous occlusion plethysmography) and glucose arteriovenous differences were evaluated over 120 minutes in 10 healthy volunteers following an ordinary mixed meal (700-900 kcal, 34% of energy from fat). Fasting arterial glucose level was 4.9+/-0.9 mmol/l, and the maximum glucose level was reached 30 minutes after the start of ingestion (6.6+/-0.8 mmol/l, p<0.0001). Plasma insulin levels were increased four-fold. FBF increased rapidly within 20 minutes after the start of ingestion and reached its maximum after 50 minutes (94% higher than baseline level, p<0.01). After 2 hours FBF was still substantially elevated (75% above baseline level, p<0.01). Forearm glucose uptake increased fivefold already after 20 minutes ( p<0.01). During the 2 hours, the increase in FBF contributed to 41% of the forearm glucose uptake ( p<0.05). The present study showed that the increase in FBF seen after an ordinary mixed meal is important for the change in forearm glucose uptake. These results support the view that modulation of limb blood flow is a determinant of glucose uptake. PMID:14605966

  9. Accuracy of handheld blood glucose meters at high altitude.

    Directory of Open Access Journals (Sweden)

    Pieter de Mol

    Full Text Available BACKGROUND: Due to increasing numbers of people with diabetes taking part in extreme sports (e.g., high-altitude trekking, reliable handheld blood glucose meters (BGMs are necessary. Accurate blood glucose measurement under extreme conditions is paramount for safe recreation at altitude. Prior studies reported bias in blood glucose measurements using different BGMs at high altitude. We hypothesized that glucose-oxidase based BGMs are more influenced by the lower atmospheric oxygen pressure at altitude than glucose dehydrogenase based BGMs. METHODOLOGY/PRINCIPAL FINDINGS: Glucose measurements at simulated altitude of nine BGMs (six glucose dehydrogenase and three glucose oxidase BGMs were compared to glucose measurement on a similar BGM at sea level and to a laboratory glucose reference method. Venous blood samples of four different glucose levels were used. Moreover, two glucose oxidase and two glucose dehydrogenase based BGMs were evaluated at different altitudes on Mount Kilimanjaro. Accuracy criteria were set at a bias 6.5 mmol/L and <1 mmol/L from reference glucose (when <6.5 mmol/L. No significant difference was observed between measurements at simulated altitude and sea level for either glucose oxidase based BGMs or glucose dehydrogenase based BGMs as a group phenomenon. Two GDH based BGMs did not meet set performance criteria. Most BGMs are generally overestimating true glucose concentration at high altitude. CONCLUSION: At simulated high altitude all tested BGMs, including glucose oxidase based BGMs, did not show influence of low atmospheric oxygen pressure. All BGMs, except for two GDH based BGMs, performed within predefined criteria. At true high altitude one GDH based BGM had best precision and accuracy.

  10. Optical coherence tomography for blood glucose monitoring through signal attenuation

    Science.gov (United States)

    De Pretto, Lucas R.; Yoshimura, Tania M.; Ribeiro, Martha S.; de Freitas, Anderson Z.

    2016-03-01

    Development of non-invasive techniques for glucose monitoring is crucial to improve glucose control and treatment adherence in patients with diabetes. Hereafter, Optical Coherence Tomography (OCT) may offer a good alternative for portable glucometers, since it uses light to probe samples. Changes in the object of interest can alter the intensity of light returning from the sample and, through it, one can estimate the sample's attenuation coefficient (μt) of light. In this work, we aimed to explore the behavior of μt of mouse's blood under increasing glucose concentrations. Different samples were prepared in four glucose concentrations using a mixture of heparinized blood, phosphate buffer saline and glucose. Blood glucose concentrations were measured with a blood glucometer, for reference. We have also prepared other samples diluting the blood in isotonic saline solution to check the effect of a higher multiple-scattering component on the ability of the technique to differentiate glucose levels based on μt. The OCT system used was a commercial Spectral Radar OCT with 930 nm central wavelength and spectral bandwidth (FWHM) of 100 nm. The system proved to be sensitive for all blood glucose concentrations tested, with good correlations with the obtained attenuation coefficients. A linear tendency was observed, with an increase in attenuation with higher values of glucose. Statistical difference was observed between all groups (pcontrol, which eliminates the use of analytes and/or test strips, as in the case with commercially available glucometers.

  11. Towards a Wearable Non-invasive Blood Glucose Monitoring Device

    International Nuclear Information System (INIS)

    Every day, about 150 Million people worldwide face the problem of diabetic metabolic control. Both the hypo- and hyper- glycaemic conditions of patients have fatal consequences and warrant blood glucose monitoring at regular interval. Existing blood glucose monitors can be widely classified into three classes viz., invasive, minimally invasive, and noninvasive. Invasive monitoring requires small volume of blood and are inappropriate for continuous monitoring of blood glucose. Minimally invasive monitors analyze tissue fluid or extract few micro litre of blood only. Also the skin injury is minimal. On the other hand, noninvasive devices are painless and void of any skin injury. We use an indigenously developed polarization sensitive Optical Coherence Tomography to measure the blood glucose levels. Current trends and recent results with the device are discussed.

  12. Tracking blood glucose and predicting prediabetes in Chinese children and adolescents: a prospective twin study.

    Directory of Open Access Journals (Sweden)

    Guoying Wang

    Full Text Available We examined the tracking of blood glucose, the development of prediabetes, and estimated their genetic contributions in a prospective, healthy, rural Chinese twin cohort. This report includes 1,766 subjects (998 males, 768 females aged 6-21 years at baseline who completed a 6-year follow-up study. Oral glucose tolerance test was performed for all subjects at both baseline and follow-up. We found that subjects with low fasting plasma glucose (FPG or 2 h post-load glucose (PG levels at baseline tended to remain at the low level at follow-up. Subjects in the top tertile of baseline plasma glucose tended to have a higher risk of developing prediabetes at follow-up compared to the low tertile: in males, 37.6% vs. 27.6% for FPG and 37.2% vs. 25.7% for 2hPG, respectively; in females, 31.0% vs. 15.4% for FPG and 28.9% vs. 15.1% for 2 h PG, respectively. Genetic factors explained 43% and 41% of the variance of FPG, and 72% and 47% for impaired fasting glucose for males and females, respectively; environmental factors substantially contribute to 2hPG status and impaired glucose tolerance. In conclusion, in this cohort of healthy rural Chinese children and adolescents, we demonstrated that both FPG and 2hPG tracked well and was a strong predictor of prediabetes. The high proportion of children with top tertile of blood glucose progressed to prediabetes, and the incidence of prediabetes has a male predominance. Genetic factors play more important role in fasting than postload status, most of which was explained by unique environmental factors.

  13. Home blood glucose concentrations in maturity-onset diabetes.

    OpenAIRE

    Paisey, R B; Bradshaw, P; Hartog, M.

    1980-01-01

    Blood glucose concentrations during normal daily activities were measured in 106 patients with maturity-onset diabetes from capillary blood samples collected on to filter paper. Samples were taken before and two hours after main meals, before going to bed, and, in 51 cases, during the night. Fasting and mid-morning values were closely correlated with the mean values over 24 hours irrespective of the type of anti-diabetic treatment being given. Postprandial blood glucose concentrations remaine...

  14. High Blood Glucose: What It Means and How To Treat It

    Science.gov (United States)

    ... Blood Glucose: What It Means and How To Treat It What is high blood glucose? People who ... to keep your blood glucose under control, and treat hyperglycemia when it occurs. What are the symptoms ...

  15. DIASTOLIC BLOOD PRESSURE OR ACTUALLY IT IS BASELINE SYSTOLIC BLOOD PRESSURE?

    Directory of Open Access Journals (Sweden)

    R.Vinodh Rajkumar

    2015-08-01

    Full Text Available Blood pressure measuring represents a routine investigation in general medicine. Nokolai Korotkoff was only 31 years old when he made a short presentation to the Scientific Meeting of the Military Hospital of the Academy on 5 November 1905 concerning an easy non-invasive method of blood pressure (BP measurement, entitled ‘Concerning the problems of the methods of blood pressure measurement’. If the pressure in the cuff is relieved, blood starts coming through the compressed arterial segment during systole and causes auscultatory sound and, the first sound, which, in Korotkoff’s opinion, is a measurement of systolic blood pressure. In the same BP measurement, when normal blood flow is fully restored, the auscultatory sounds disappear and, the last sound, which, in Korotkoff's opinion is a measurement of diastolic blood pressure. Listening to Korotkoff sounds (K-sounds to determine systolic and diastolic blood pressure (BP has been the standard for noninvasive BP measurement in medical practices for nearly 100 years and it is the essential tool used for evaluation and assessment of patients with hypertension and risks of cardiovascular diseases (CVD by physicians and nurses despite limited understanding of the nature of K-sounds. This article focuses particularly on the cardiovascular biomechanics of the first and last auscultatory sound and suggests two new terminologies; Highest systolic blood pressure and Baseline systolic blood pressure to represent the systolic pressure and diastolic pressure, respectively. Experimenting blood pressures on the basis of these two new suggested terminologies may reveal various additional undiscovered aspects of normal BP and abnormal BP. KEY WORDS: Highest systolic blood pressure, Baseline systolic blood pressure, Korotkoff sounds

  16. INTERNET-BASED CONTINGENCY MANAGEMENT TO IMPROVE ADHERENCE WITH BLOOD GLUCOSE TESTING RECOMMENDATIONS FOR TEENS WITH TYPE 1 DIABETES

    OpenAIRE

    Raiff, Bethany R.; Dallery, Jesse

    2010-01-01

    The current study used Internet-based contingency management (CM) to increase adherence with blood glucose testing to at least 4 times daily. Four teens diagnosed with Type 1 diabetes earned vouchers for submitting blood glucose testing videos over a Web site. Participants submitted a mean of 1.7 and 3.1 blood glucose tests per day during the 2 baseline conditions, respectively, compared to 5.7 tests per day during the intervention. Participants and their guardians rated the program favorably...

  17. Optical coherence tomography for blood glucose monitoring through signal attenuation

    Science.gov (United States)

    De Pretto, Lucas R.; Yoshimura, Tania M.; Ribeiro, Martha S.; de Freitas, Anderson Z.

    2016-03-01

    Development of non-invasive techniques for glucose monitoring is crucial to improve glucose control and treatment adherence in patients with diabetes. Hereafter, Optical Coherence Tomography (OCT) may offer a good alternative for portable glucometers, since it uses light to probe samples. Changes in the object of interest can alter the intensity of light returning from the sample and, through it, one can estimate the sample's attenuation coefficient (μt) of light. In this work, we aimed to explore the behavior of μt of mouse's blood under increasing glucose concentrations. Different samples were prepared in four glucose concentrations using a mixture of heparinized blood, phosphate buffer saline and glucose. Blood glucose concentrations were measured with a blood glucometer, for reference. We have also prepared other samples diluting the blood in isotonic saline solution to check the effect of a higher multiple-scattering component on the ability of the technique to differentiate glucose levels based on μt. The OCT system used was a commercial Spectral Radar OCT with 930 nm central wavelength and spectral bandwidth (FWHM) of 100 nm. The system proved to be sensitive for all blood glucose concentrations tested, with good correlations with the obtained attenuation coefficients. A linear tendency was observed, with an increase in attenuation with higher values of glucose. Statistical difference was observed between all groups (p<0.001). This work opens the possibility towards a non-invasive diagnostic modality using OCT for glycemic control, which eliminates the use of analytes and/or test strips, as in the case with commercially available glucometers.

  18. A data driven nonlinear stochastic model for blood glucose dynamics.

    Science.gov (United States)

    Zhang, Yan; Holt, Tim A; Khovanova, Natalia

    2016-03-01

    The development of adequate mathematical models for blood glucose dynamics may improve early diagnosis and control of diabetes mellitus (DM). We have developed a stochastic nonlinear second order differential equation to describe the response of blood glucose concentration to food intake using continuous glucose monitoring (CGM) data. A variational Bayesian learning scheme was applied to define the number and values of the system's parameters by iterative optimisation of free energy. The model has the minimal order and number of parameters to successfully describe blood glucose dynamics in people with and without DM. The model accounts for the nonlinearity and stochasticity of the underlying glucose-insulin dynamic process. Being data-driven, it takes full advantage of available CGM data and, at the same time, reflects the intrinsic characteristics of the glucose-insulin system without detailed knowledge of the physiological mechanisms. We have shown that the dynamics of some postprandial blood glucose excursions can be described by a reduced (linear) model, previously seen in the literature. A comprehensive analysis demonstrates that deterministic system parameters belong to different ranges for diabetes and controls. Implications for clinical practice are discussed. This is the first study introducing a continuous data-driven nonlinear stochastic model capable of describing both DM and non-DM profiles. PMID:26707373

  19. Prediction methods for blood glucose concentration design, use and evaluation

    CERN Document Server

    Jørgensen, John; Renard, Eric; Re, Luigi

    2016-01-01

    This book tackles the problem of overshoot and undershoot in blood glucose levels caused by delay in the effects of carbohydrate consumption and insulin administration. The ideas presented here will be very important in maintaining the welfare of insulin-dependent diabetics and avoiding the damaging effects of unpredicted swings in blood glucose – accurate prediction enables the implementation of counter-measures. The glucose prediction algorithms described are also a key and critical ingredient of automated insulin delivery systems, the so-called “artificial pancreas”. The authors address the topic of blood-glucose prediction from medical, scientific and technological points of view. Simulation studies are utilized for complementary analysis but the primary focus of this book is on real applications, using clinical data from diabetic subjects. The text details the current state of the art by surveying prediction algorithms, and then moves beyond it with the most recent advances in data-based modeling o...

  20. Temperature influence on non-invasive blood glucose measurement

    Science.gov (United States)

    Zhang, Xiqin; Yeo, Joon Hock

    2009-02-01

    Regular monitoring of blood sugar level is important for the management of diabetes. The Near-Infra-Red (NIR) spectroscopy method is a promising approach and this involves some form of contact with the body skin. It is noted that the skin temperature does fluctuate with the environment and physiological conditions and the temperature has an influence on the glucose measurement. In this paper, in-vitro and in-vivo investigations on the temperature influence on blood glucose measurement were studied. The in-vitro results from FTIR spectrometer show that sample temperature has significant influence on water absorption, which significantly affects the glucose absorption measurement. The in-vivo results show that when skin temperature around the measurement site is taken into consideration, the prediction of blood glucose level greatly improves.

  1. Use of a blood glucose meter for radiochromic film analysis in blood irradiation

    International Nuclear Information System (INIS)

    The use of a diabetic blood glucose meter for radiochromic film dosimetry in blood irradiation using x-ray beams on a medical linear accelerator has been investigated. The glucose meter provides optical density analysis in the visible and infrared region using a reflectance measurement technique. By comparing the 'blood sugar' level output with standard calibration gafchromic films a calibration curve is produced for quantitative analysis. Results show that a reproducible dose to meter output curve can be fitted using a second order polynomial function and that blood irradiation doses in vitro were measured to within 7.9% mean error (as compared to ionization chamber results) using the blood glucose meter. This level of accuracy falls below that measured with a standard densitometer (4.3%); however, results show that the blood glucose meter, which would be available in any haematology department, produces an adequate measure of gafchromic film optical density for blood irradiation dosimetry. (author)

  2. Using statistical quality control techniques to monitor blood glucose levels.

    OpenAIRE

    Oniki, T. A.; Clemmer, T. P.; Arthur, L. K.; Linford, L. H.

    1995-01-01

    Continuous Quality Improvement techniques developed in industry are increasingly being applied to the medical field. Statistical process control charts are a CQI technique aimed at monitoring a process and its variability. At our hospital, statistical quality control charts are being constructed from laboratory blood glucose measurements of patients receiving enteral or parenteral nutrition. The charts will be used to monitor glucose levels, reveal variations, and illustrate the effects of ne...

  3. Inhaled insulin for controlling blood glucose in patients with diabetes

    Directory of Open Access Journals (Sweden)

    Bernard L Silverman

    2008-01-01

    Full Text Available Bernard L Silverman1, Christopher J Barnes2, Barbara N Campaigne3, Douglas B Muchmore31Alkermes, Inc, Cambridge, MA, USA; 2i3 Statprobe, Ann Arbor, MI; 3Eli Lilly and Company, Indianapolis, IN, USAAbstract: Diabetes mellitus is a significant worldwide health problem, with the incidence of type 2 diabetes increasing at alarming rates. Insulin resistance and dysregulated blood glucose control are established risk factors for microvascular complications and cardiovascular disease. Despite the recognition of diabetes as a major health issue and the availability of a growing number of medications designed to counteract its detrimental effects, real and perceived barriers remain that prevent patients from achieving optimal blood glucose control. The development and utilization of inhaled insulin as a novel insulin delivery system may positively influence patient treatment adherence and optimal glycemic control, potentially leading to a reduction in cardiovascular complications in patients with diabetes.Keywords: diabetes, inhaled insulin, cardiovascular disease, blood glucose

  4. Whole blood glucose analysis based on smartphone camera module.

    Science.gov (United States)

    Devadhasan, Jasmine Pramila; Oh, Hyunhee; Choi, Cheol Soo; Kim, Sanghyo

    2015-11-01

    Complementary metal oxide semiconductor (CMOS) image sensors have received great attention for their high efficiency in biological applications. The present work describes a CMOS image sensor-based whole blood glucose monitoring system through a point-of-care (POC) approach. A simple poly-ethylene terephthalate (PET) chip was developed to carry out the enzyme kinetic reaction at various concentrations (110–586 mg∕dL) of mouse blood glucose. In this technique, assay reagent is immobilized onto amine functionalized silica (AFSiO2) nanoparticles as an electrostatic attraction in order to achieve glucose oxidation on the chip. The assay reagent immobilized AFSiO2 nanoparticles develop a semi-transparent reaction platform, which is technically a suitable chip to analyze by a camera module. The oxidized glucose then produces a green color according to the glucose concentration and is analyzed by the camera module as a photon detection technique; the photon number decreases when the glucose concentration increases. The combination of these components, the CMOS image sensor and enzyme immobilized PET film chip, constitute a compact, accurate, inexpensive, precise, digital, highly sensitive, specific, and optical glucose-sensing approach for POC diagnosis. PMID:26524683

  5. Whole blood glucose analysis based on smartphone camera module

    Science.gov (United States)

    Devadhasan, Jasmine Pramila; Oh, Hyunhee; Choi, Cheol Soo; Kim, Sanghyo

    2015-11-01

    Complementary metal oxide semiconductor (CMOS) image sensors have received great attention for their high efficiency in biological applications. The present work describes a CMOS image sensor-based whole blood glucose monitoring system through a point-of-care (POC) approach. A simple poly-ethylene terephthalate (PET) chip was developed to carry out the enzyme kinetic reaction at various concentrations (110-586 mg/dL) of mouse blood glucose. In this technique, assay reagent is immobilized onto amine functionalized silica (AFSiO2) nanoparticles as an electrostatic attraction in order to achieve glucose oxidation on the chip. The assay reagent immobilized AFSiO2 nanoparticles develop a semi-transparent reaction platform, which is technically a suitable chip to analyze by a camera module. The oxidized glucose then produces a green color according to the glucose concentration and is analyzed by the camera module as a photon detection technique; the photon number decreases when the glucose concentration increases. The combination of these components, the CMOS image sensor and enzyme immobilized PET film chip, constitute a compact, accurate, inexpensive, precise, digital, highly sensitive, specific, and optical glucose-sensing approach for POC diagnosis.

  6. Predicting Mortality of Critically Ill Patients by Blood Glucose Levels

    Directory of Open Access Journals (Sweden)

    Byung Sam Park

    2013-10-01

    Full Text Available BackgroundThe aim of this study is to observe the outcome of critically ill patients in relation to blood glucose level at admission and to determine the optimal range of blood glucose at admission predicting lower hospital mortality among critically ill patients.MethodsWe conducted a retrospective cohort study of a total 1,224 subjects (males, 798; females, 426 admitted to intensive care unit (ICU from 1 January 2009 to 31 December 2010. Blood glucose levels at admission were categorized into four groups (group 1, <100 mg/dL; group 2, 100 to 199 mg/dL; group 3, 200 to 299 mg/dL; and group 4, ≥300 mg/dL.ResultsAmong 1,224 patients, 319 patients were already known diabetics, and 296 patients died in ICU. Five hundred fifty-seven subjects received insulin therapy, and 118 received oral hypoglycemic agents. The overall mortality rate was 24.2% (296 patients. The causes of death and mortality rates of diabetic patients were not different from nondiabetic subjects. The mortality curve showed J shape, and there were significant differences in mortality between the groups of blood glucose levels at admission. Group 2 had the lowest mortality rate (P<0.05.ConclusionThese results suggest that serum glucose levels upon admission into ICU is associated with clinical outcomes in ICU patients. Blood glucose level between 100 and 199 mg/dL at the time of ICU admission could predict lower hospital mortality among critically ill patients.

  7. High and Low Glycemic Index Mixed Meals and Blood Glucose in Youth with Type 2 Diabetes or Impaired Glucose Tolerance

    OpenAIRE

    Gellar, Lauren; Nansel, Tonja R.

    2009-01-01

    This cross-over pilot study tested blood glucose response to low and high glycemic index meals in 12 obese youth with type 2 diabetes or impaired glucose tolerance. Participants demonstrated significantly lower mean daytime blood glucose and a trend toward lower variability, suggesting a clinically relevant impact of reducing glycemic index.

  8. Effects of MDMA on blood glucose levels and brain glucose metabolism

    Energy Technology Data Exchange (ETDEWEB)

    Soto-Montenegro, M.L.; Vaquero, J.J.; Garcia-Barreno, P.; Desco, M. [Hospital General Universitario Gregorio Maranon, Laboratorio de Imagen, Medicina Experimental, Madrid (Spain); Arango, C. [Hospital General Gregorio Maranon, Departamento de Psiquiatria, Madrid (Spain); Ricaurte, G. [Johns Hopkins University School of Medicine, Department of Neurology, Baltimore, MD (United States)

    2007-06-15

    This study was designed to assess changes in glucose metabolism in rats administered single or repeated doses of MDMA. Two different experiments were performed: (1) A single-dose study with four groups receiving 20 mg/kg, 40 mg/kg, saline or heat, and (2) a repeated-dose study with two groups receiving three doses, at intervals of 2 h, of 5 mg/kg or saline. Rats were imaged using a dedicated small-animal PET scanner 1 h after single-dose administration or 7 days after repeated doses. Glucose metabolism was measured in 12 cerebral regions of interest. Rectal temperature and blood glucose were monitored. Peak body temperature was reached 1 h after MDMA administration. Blood glucose levels decreased significantly after MDMA administration. In the single-dose experiment, brain glucose metabolism showed hyperactivation in cerebellum and hypo-activation in the hippocampus, amygdala and auditory cortex. In the repeated-dose experiment, brain glucose metabolism did not show any significant change at day 7. These results are the first to indicate that MDMA has the potential to produce significant hypoglycaemia. In addition, they show that MDMA alters glucose metabolism in components of the motor, limbic and somatosensory systems acutely but not on a long-term basis. (orig.)

  9. Effects of MDMA on blood glucose levels and brain glucose metabolism

    International Nuclear Information System (INIS)

    This study was designed to assess changes in glucose metabolism in rats administered single or repeated doses of MDMA. Two different experiments were performed: (1) A single-dose study with four groups receiving 20 mg/kg, 40 mg/kg, saline or heat, and (2) a repeated-dose study with two groups receiving three doses, at intervals of 2 h, of 5 mg/kg or saline. Rats were imaged using a dedicated small-animal PET scanner 1 h after single-dose administration or 7 days after repeated doses. Glucose metabolism was measured in 12 cerebral regions of interest. Rectal temperature and blood glucose were monitored. Peak body temperature was reached 1 h after MDMA administration. Blood glucose levels decreased significantly after MDMA administration. In the single-dose experiment, brain glucose metabolism showed hyperactivation in cerebellum and hypo-activation in the hippocampus, amygdala and auditory cortex. In the repeated-dose experiment, brain glucose metabolism did not show any significant change at day 7. These results are the first to indicate that MDMA has the potential to produce significant hypoglycaemia. In addition, they show that MDMA alters glucose metabolism in components of the motor, limbic and somatosensory systems acutely but not on a long-term basis. (orig.)

  10. Exposure-based treatment to control excessive blood glucose monitoring.

    OpenAIRE

    Allen, K D; Evans, J. H.

    2001-01-01

    We investigated an exposure-based procedure for reducing excessive checking of blood glucose by a child with diabetes. In a changing criterion design, an exposure-based procedure was implemented by systematically exposing the child to decreasing amounts of information about blood sugar levels (checking) and thereby increasing exposure to potential hypoglycemia. Access to information was reduced in graduated increments, with the parents setting criteria to levels at which they were willing to ...

  11. Hybrid CARS for Non-Invasive Blood Glucose Monitoring

    Science.gov (United States)

    Wang, Xi; Pestov, Dmitry; Zhang, Aihua; Murawski, Robert; Sokolov, Alexei; Welch, George; Laane, Jaan; Scully, Marlan

    2007-10-01

    We develop a spectroscopy technique that combines the advantages of both the frequency-resolved coherent anti-Stokes Raman scattering (CARS) and the time-resolved CARS. We use broadband preparation pulses to get an instantaneous coherent excitation of multiplex molecular vibration levels and subsequent optically shaped time-delayed narrowband probing pulse to detect these vibrations. This technique can suppress the nonresonant background and retrieve the molecular fingerprint signal efficiently and rapidly. We employ this technique to glucose detection, the final goal of which is accurate, non-invasive (i.e. painless) and continuous monitoring of blood glucose concentration in the Diabetes diagnosis to replace the current glucose measurement process, which requires painful fingerpricks and therefore cannot be performed more than a few times a day. We have gotten the CARS spectra of glucose aqueous solution down to 2 mM.

  12. Predictors of Daily Blood Glucose Monitoring in Appalachian Ohio

    Science.gov (United States)

    Raffle, Holly; Ware, Lezlee J.; Ruhil, Anirudh V. S.; Hamel-Lambert, Jane; Denham, Sharon A.

    2012-01-01

    Objective: To determine factors contributing to successful diabetes self-management in Appalachia, as evidenced by daily blood glucose monitoring. Methods: A telephone survey (N = 3841) was conducted to assess health status and health care access. The current investigation is limited to the subset of this sample who report having diabetes (N =…

  13. Dynamical Analysis in the Mathematical Modelling of Human Blood Glucose

    Science.gov (United States)

    Bae, Saebyok; Kang, Byungmin

    2012-01-01

    We want to apply the geometrical method to a dynamical system of human blood glucose. Due to the educational importance of model building, we show a relatively general modelling process using observational facts. Next, two models of some concrete forms are analysed in the phase plane by means of linear stability, phase portrait and vector…

  14. Urinary phthalate metabolite concentrations and blood glucose levels during pregnancy

    Science.gov (United States)

    Robledo, Candace A.; Peck, Jennifer D.; Stoner, Julie; Calafat, Antonia M.; Carabin, Hélène; Cowan, Linda; Goodman, Jean R.

    2016-01-01

    Purpose To examine associations between phthalate metabolite urinary concentrations during early pregnancy and blood glucose levels obtained at the time of screening for gestational diabetes mellitus (GDM). Methods Upon initiation of prenatal care, women with a mean gestational age of 12.8 weeks were recruited for a study of environmental chemical exposures (n = 110) and provided a spot urinary specimen. Blood glucose concentrations (mg/dl) were obtained from the electronic medical record for those patients who did not experience a pregnancy loss and did not transfer care to another facility prior to glucose screening (n = 72). Urinary concentrations of nine phthalate metabolites and creatinine were measured at the US Centers for Disease Control and Prevention. Associations between tertiles of phthalate metabolites concentrations and blood glucose levels were estimated using linear regression. Results Compared to pregnant women in the lowest concentration tertile, women with the highest urinary concentrations (≥3rd tertile) of mono-iso-butyl phthalate (tertile: ≥15.3 μg/l, β = −18.3, 95% CI: −35.4, −1.2) and monobenzyl phthalate (tertile: ≥30.3 μg/l, β = −17.3, 95% CI: −34.1, −0.4) had lower blood glucose levels at the time of GDM screening after adjustment for urinary creatinine and demographic covariates. Conclusion Because maternal glucose levels increase during pregnancy to provide adequate nutrition for fetal growth and development, these findings may have implications for fetal health. However, given the limitations of our study, findings should be interpreted cautiously. PMID:25726127

  15. Effect of n-3 fatty acid supplementation on blood glucose, lipid profile and cytokines in humans: A pilot study

    OpenAIRE

    Raghu, B.; Venkatesan, P

    2008-01-01

    This study was undertaken to evaluate the effects of n-3 fatty acid supplementation on blood glucose, lipid profile and cytokines in humans. Twenty adult healthy subjects were supplemented with 1g/day fish oil concentrate capsules for 2 weeks. Fasting blood samples were taken at baseline and again after 2 week intervention. Fish oil supplementation significantly lowered fasting serum concentrations of total cholesterol, triacylglycerol, very low density lipoprotein and low density lipoprotein...

  16. Electroacupuncture for control of blood glucose in diabetes: literature review.

    Science.gov (United States)

    Peplow, Philip V; Baxter, G David

    2012-02-01

    Electrical stimulation at acupuncture points (acupoints) has been investigated for its utility in lowering blood glucose in hyperglycemic humans and animal models. Only two studies were found using electroacupuncture in human subjects, and in both of these, the participants were normal (nondiabetic) and electrical stimulation was carried out at several acupoints. It had a hypoglycemic effect in obese women with calorific restriction diet using electrical stimulation of 2 Hz for 30 minutes/day for 20 days, but no change occurred in blood glucose of fasted patients in the other study using 1 Hz for 15 minutes. Fourteen animal studies were found, of which, 11 were performed in diabetic and normal rats. A hypoglycemic effect was observed in fasted type 1 diabetic rats using the Zusanli (ST36) leg acupoint with electrical stimulation of 15 Hz for 30 minutes and 60 minutes. In fasted type 2 diabetic rats, blood glucose was lowered using the Zusanli acupoint with electrical stimulation parameters of 15 Hz and 10 mA for 30 minutes. Also, using the Zhongwan (CV12) abdomen acupoint with electrical stimulation parameters of 15 Hz and 10 mA for 90 minutes had a hypoglycemic effect in fasted type 2 diabetic rats. In fasted normal rats, electrical stimulation of 2 Hz or 15 Hz for 30 minutes at the Zusanli or Zhongwan acupoint caused a decrease in blood glucose. Future studies are required in fasted diabetic rats to determine the effect of electroacupuncture on blood levels of insulin, lipids, fatty acids and β-endorphin, and blood flow and nerve conduction velocity. Studies with fasted normal and diabetic human subjects treated by electroacupuncture are warranted using data from animal experiments to inform such studies. PMID:22309901

  17. Influence of Artificial Sweetener on Human Blood Glucose Concentration

    Directory of Open Access Journals (Sweden)

    Ilse Skokan

    2007-01-01

    Full Text Available Artificial sweeteners, such as saccharin or cyclamic acid are synthetically manufactured sweetenings. Known for their low energetic value they serve especially diabetic and adipose patients as sugar substitutes. It has been hypothesized that the substitution of sugar with artificial sweeteners may induce a decrease of the blood glucose. The aim of this study was to determine the reliability of this hypothesis by comparing the influence of regular table sugar and artificial sweeteners on the blood glucose concentration. In this pilot-study 16 patients were included suffering from adiposity, pre-diabetes and hypertension. In the sense of a cross-over design, three test trials were performed at intervals of several weeks. Each trial was followed by a test free interval. Within one test trial each patient consumed 150 ml test solution (water that contained either 6 g of table sugar (“Kandisin” with sweetener free serving as control group. Tests were performed within 1 hr after lunch to ensure conditions comparable to patients having a desert. Every participant had to determine their blood glucose concentration immediately before and 5, 15, 30 and 60 minutes after the intake of the test solution. For statistics an analysis of variance was performed. The data showed no significant changes in the blood glucose concentration. Neither the application of sugar (F4;60 = 1.645; p = .175 nor the consumption of an artificial sweetener (F2.068;31.023 = 1.551; p > .05 caused significant fluctuations in the blood sugar levels. Over a time frame of 60 minutes in the control group a significant decrease of the blood sugar concentration was found (F2.457;36.849 = 4.005; p = .020 as a physiological reaction during lunch digestion.

  18. Near-infrared spectral methods for noninvasively measuring blood glucose

    Science.gov (United States)

    Fei, Sun; Kong, Deyi; Mei, Tao; Tao, Yongchun

    2004-05-01

    Determination of blood glucose concentrations in diabetic patients is a frequently occurring procedure and an important tool for diabetes management. Use of noninvasive detection techniques can relieve patients from the pain of frequent finger pokes and avoid the infection of disease via blood. This thesis discusses current research and analyzes the advantages and shortages of different measurement methods, including: optical methods (Transmission, Polarimetry and scattering), then, we give emphasis to analyze the technology of near-infrared (NIR) spectra. NIR spectral range 700 nm ~2300 nm was used because of its good transparency for biological tissue and presence of glucose absorption band. In this work, we present an outline of noninvasive blood glucose measurement. A near-infrared light beam is passed through the finger, and the spectral components of the emergent beam are measured using spectroscopic techniques. The device includes light sources having the wavelengths of 600 nm - 1800 nm to illuminate the tissue. Receptors associated with the light sources for receiving light and generating a transmission signal representing the light transmitted are also provided. Once a transmission signal is received by receptors, and the high and low values from each of the signals are stored in the device. The averaged values are then analyzed to determine the glucose concentration, which is displayed on the device.

  19. Noninvasive biosensor and wireless interrogating system for glucose in blood

    Science.gov (United States)

    Varadan, Vijay K.; Whitchurch, Ashwin K.; Sarukesi, K.

    2003-07-01

    Hypoglycemia-abnormal decrease in blood sugar-is a major obstacle in the management of diabetes and prevention of long-term complications, and it may impose serious effects on the brain, including impairment of memory and other cognitive functions. This paper presents the development of a non-invasive sensor with miniaturized telemetry device in a wrist-watch for monitoring glucose concentration in blood. The sensor concept is based on optical chirality of glucose level in the interstitial fluid. The wrist watch consists of a laser power source of the wavelength compatible with the glucose. A nanofilm with specific chirality is placed at the bottom of the watch. The light then passes through the film and illuminates a small area on the skin. It has been documented that there is certain concentration of sugar level is taken by the intertitial fluid from the blood stream and deposit a portion of it at the dead skin. The wrist-watch when in contact with the outer skin of the human will thus monitor the glucose concentration. A wireless monitoring system in the watch then downloads the data from the watch to a Palm or a laptop computer.

  20. Nanostructured gold electrodes for determination of glucose in blood

    Czech Academy of Sciences Publication Activity Database

    Farka, Z.; Juřík, T.; Kovář, D.; Podešva, Pavel; Foret, František; Skladal, P.

    Brno: Ústav analytické chemie AV ČR, v. v. i, 2015 - (Foret, F.; Křenková, J.; Drobníková, I.; Klepárník, K.), s. 54-57 ISBN 978-80-904959-3-7. [CECE 2015. International Interdisciplinary Meeting on Bioanalysis /12./. Brno (CZ), 21.09.2015-23.09.2015] Institutional support: RVO:68081715 Keywords : monitoring of glucose * glucometers * non-enzymatic glucose determination * human blood serum Subject RIV: CB - Analytical Chemistry, Separation http://www.ce-ce.org/CECE2015/CECE%202015%20proceedings_full.pdf

  1. Nanostructured gold electrodes for determination of glucose in blood

    Czech Academy of Sciences Publication Activity Database

    Farka, Z.; Juřík, T.; Kovář, D.; Podešva, Pavel; Foret, František; Skladal, P.

    Brno : Ústav analytické chemie AV ČR, v. v. i, 2015 - (Foret, F.; Křenková, J.; Drobníková, I.; Klepárník, K.), s. 54-57 ISBN 978-80-904959-3-7. [CECE 2015. International Interdisciplinary Meeting on Bioanalysis /12./. Brno (CZ), 21.09.2015-23.09.2015] Institutional support: RVO:68081715 Keywords : monitoring of glucose * glucometers * non-enzymatic glucose determination * human blood serum Subject RIV: CB - Analytical Chemistry, Separation http://www.ce-ce.org/CECE2015/CECE%202015%20proceedings_full.pdf

  2. Facilitated transport of glucose from blood to brain in man and the effect of moderate hypoglycaemia on cerebral glucose utilization

    International Nuclear Information System (INIS)

    The effect of steady-state moderate hypoglycaemia on human brain homeostasis has been studied with positron emission tomography using D-glucose 11C(ul) as tracer. To rule out any effects of insulin, the plasma insulin concentration was maintained at the same level under normo- and hypoglycaemic conditions. Reduction of blood glucose by 55% increased the glucose clearance through the blood-brain barrier by 50% and reduced brain glucose consumption by 40%. Blood flow was not affected. The results are consistent with facilitated transport of glucose from blood to brain in humans. The maximal transport rate of glucose from blood to brain was found to be 62±19 (mean±SEM) μmol hg-1 min-1, and the half-saturation constant was found to be 4.1±3.2 mM. (orig.)

  3. Pre-exercise glucose ingestion at different time periods and blood glucose concentration during exercise.

    Science.gov (United States)

    Tokmakidis, S P; Volaklis, K A

    2000-08-01

    The purpose of this study was to investigate the effects of glucose ingestion (GI) at different time periods prior to exercise on blood glucose (BG) levels during prolonged treadmill running. Eight subjects (X+/-SD), age 20+/-0.5yr, bodymass 70.7+/-4.1 kg, height 177+/-4 cm, VO2max 52.8+/-7.8 ml x kg(-1) x min(-1) who underwent different experimental conditions ingested a glucose solution (1 g/kg at 350 ml) 30 min (gl-30), 60 min (gl-60), 90 min (gl-90), and a placebo one 60 min (pl-60) prior to exercise in a counterbalanced design. Afterwards they ran at 65% of VO2max for 1 hour and then at 75 % of VO2max till exhaustion. Fingertip blood samples (10 microl) were drawn every 15 min before and during exercise for the determination of BG levels. Oxygen uptake (VO2), heart rate (HR), and blood lactate (La) were also measured every 15 min during exercise. Peak BG values were reached within 30 min after GI but were different (p affect the duration of treadmill running. The La levels were higher (p affecting the duration of running performance at 75% VO2max. Thus, in order to maintain normoglycaemic levels, pre-exercise glucose supplementation should be given 30 min before the onset of exercise. PMID:10961522

  4. Inhaled insulin for controlling blood glucose in patients with diabetes

    OpenAIRE

    Silverman, Bernard L; Barnes, Christopher J.; Campaigne, Barbara N.; Muchmore, Douglas B.

    2007-01-01

    Diabetes mellitus is a significant worldwide health problem, with the incidence of type 2 diabetes increasing at alarming rates. Insulin resistance and dysregulated blood glucose control are established risk factors for microvascular complications and cardiovascular disease. Despite the recognition of diabetes as a major health issue and the availability of a growing number of medications designed to counteract its detrimental effects, real and perceived barriers remain that prevent patients ...

  5. Influence of Artificial Sweetener on Human Blood Glucose Concentration

    OpenAIRE

    Ilse Skokan; P. Christian Endler; Beatrix Wulkersdorfer; Dieter Magometschnigg; Heinz Spranger

    2007-01-01

    Artificial sweeteners, such as saccharin or cyclamic acid are synthetically manufactured sweetenings. Known for their low energetic value they serve especially diabetic and adipose patients as sugar substitutes. It has been hypothesized that the substitution of sugar with artificial sweeteners may induce a decrease of the blood glucose. The aim of this study was to determine the reliability of this hypothesis by comparing the influence of regular table sugar and artificial sweeteners on the b...

  6. Perioperative control of blood glucose level in cardiac surgery.

    OpenAIRE

    Minakata, Kenji; Sakata, Ryuzo

    2013-01-01

    It is well recognized that poor perioperative blood glucose (BG) control can increase the risk of infection, cardiovascular accidents, and even death in patients undergoing cardiac surgery. Since it has been reported that tight BG control (80-110 mg/dL) yields better outcomes in critically ill patients, it became a standard of care to control BG using intravenous insulin infusion in ICU. However, it has been debated in terms of the optimal target range whether a strict control with intensive ...

  7. Evaluation of the appropriateness of using glucometers for measuring the blood glucose levels in mice.

    Science.gov (United States)

    Togashi, Yu; Shirakawa, Jun; Okuyama, Tomoko; Yamazaki, Shunsuke; Kyohara, Mayu; Miyazawa, Ayumi; Suzuki, Takafumi; Hamada, Mari; Terauchi, Yasuo

    2016-01-01

    Glucometers are also widely used in diabetes research conducted using animal models. However, the appropriateness of measuring blood glucose levels using glucometers in animal models remains unclear. In this study, we evaluated the consistency between the blood glucose levels measured by 11 models of glucometers and plasma glucose levels measured by a laboratory biochemical test in blood samples collected by retro-orbital sinus puncture or tail-tip amputation. In both blood samples obtained by retro-orbital sinus puncture and those obtained by tail-tip amputation, 10 of the 11 models of glucometers yielded higher glucose values, while 1 yielded lower glucose values, than the plasma glucose values yielded by the laboratory test, the differences being in direct proportion to the plasma glucose values. Most glucometers recorded higher blood glucose levels after glucose loading and lower blood glucose levels after insulin loading in retro-orbital sinus blood as compared to tail vein blood. Our data suggest that the blood glucose levels measured by glucometers in mice tended to be higher than the plasma glucose levels yielded by the biochemical test under the hyperglycemic state, and that differences in the measured levels were observed according to the blood collection method depending on the glycemia status. PMID:27151424

  8. Splanchnic blood flow and hepatic glucose production in exercising humans

    DEFF Research Database (Denmark)

    Bergeron, R; Kjaer, M; Simonsen, L;

    2001-01-01

    The study examined the implication of the renin-angiotensin system (RAS) in regulation of splanchnic blood flow and glucose production in exercising humans. Subjects cycled for 40 min at 50% maximal O(2) consumption (VO(2 max)) followed by 30 min at 70% VO(2 max) either with [angiotensin-converti......The study examined the implication of the renin-angiotensin system (RAS) in regulation of splanchnic blood flow and glucose production in exercising humans. Subjects cycled for 40 min at 50% maximal O(2) consumption (VO(2 max)) followed by 30 min at 70% VO(2 max) either with [angiotensin......-converting enzyme (ACE) blockade] or without (control) administration of the ACE inhibitor enalapril (10 mg iv). Splanchnic blood flow was estimated by indocyanine green, and splanchnic substrate exchange was determined by the arteriohepatic venous difference. Exercise led to an approximately 20-fold increase (P ...-blockade group vs. the control group, hormones, metabolites, VO(2), and RER followed the same pattern of changes in ACE-blockade and control groups during exercise. Splanchnic blood flow (at rest: 1.67 +/- 0.12, ACE blockade; 1.59 +/- 0.18 l/min, control) decreased during moderate exercise (0.78 +/- 0.07, ACE...

  9. Capillary Bedside Blood Glucose Measurement in Neonates: Missing a Diagnosis of Galactosemia

    OpenAIRE

    Özbek, Mehmet Nuri; Öcal, Murat; Tanrıverdi, Sibel; Baysal, Birsen; Deniz, Ahmet; Öncel, Kahraman; Demirbilek, Hüseyin

    2015-01-01

    A number of factors may lead to inaccuracy in measurement of capillary blood glucose with a glucometer. Measurement of other carbohydrate molecules such as galactose and fructose along with glucose can potentially be a cause of error. We report a newborn patient who was referred to our hospital with conjugated bilirubinemia, hepatomegaly and high capillary blood glucose levels measured with a glucometer. Simultaneous biochemical measurements revealed normal blood glucose levels. Further inves...

  10. Assessment of Self-Monitored Blood Glucose Results Using a Reflectance Meter with Memory and Microcomputer

    OpenAIRE

    Kuykendall, V.G.; Michaels, D W; Hartmann, K.G.

    1985-01-01

    A microcomputer software package for diabetes patient care utilizing self-monitoring of blood glucose (SMBG) has been developed. The software facilitates the collection, storage, analysis, and presentation of blood glucose/time information. Data entry is accomplished automatically via interface to hand held blood glucose reflectance instruments which retain up to 339 glucose/time results in internal RAM. The times of other significant clinical events may also be stored in the meter and upload...

  11. Development of a fluorescent method for simultaneous measurement of glucose concentrations in interstitial fluid and blood

    International Nuclear Information System (INIS)

    Continuous blood glucose monitoring is of great clinical significance to patients with diabetes. One of the effective methods to monitor blood glucose is to measure glucose concentrations of interstitial fluid (ISF). However, a time-delay problem exists between ISF and blood glucose concentrations, which results in difficulty in indicating real-time blood glucose concentrations. Therefore, we developed a fluorescent method to verify the accuracy and reliability of simultaneous ISF and blood glucose measurement, especially incorporating it into research on the delay relationship between blood and ISF glucose changes. This method is based on a competitive reaction among borate polymer, alizarin and glucose. When glucose molecules combine with borate polymers in alizarin–borate polymer competitively, changes in fluorescence intensity demonstrate changes in glucose concentrations. By applying the measured results to the blood and ISF glucose delay relationship, we were able to calculate the time delay as an average of 2.16 ± 2.05 min for ISF glucose changes with reference to blood glucose concentrations. (paper)

  12. Effect of local corticosteroid injection of the hand and wrist on blood glucose in patients with diabetes mellitus.

    Science.gov (United States)

    Catalano, Louis W; Glickel, Steven Z; Barron, O Alton; Harrison, Richard; Marshall, Astrid; Purcelli-Lafer, Marissa

    2012-12-01

    Locally administered corticosteroids are a common therapy in many hand and wrist disorders. Corticosteroids pose a theoretical risk to patients with diabetes mellitus by potentially raising blood glucose to hyperglycemic levels. Although oral corticosteroids are known to have an effect on blood glucose control, limited data exist on extra-articular administration. The purpose of this study was to examine the systemic impact of extra-articularly administered corticosteroids in the hand and wrist on serum glucose concentration in patients with diabetes mellitus.Twenty-three patients with diabetes mellitus received a 1-mL triamcinolone acetonide injection for de Quervain's tenosynovitis, trigger finger, flexor carpi ulnaris tendonitis, or carpal tunnel syndrome. Patients recorded their daily morning blood glucose levels for 1 week before injection and for 4 weeks after injection. Average blood glucose levels increased slightly from baseline after injection, reaching statistical significance 1, 5, and 6 days after injection, but were not clinically significant (average increase, 14.2, 9.7, and 32.7 mg/dL, respectively). Isolated increases more than 2 times the standard deviation of preinjection values occurred at least once in the majority of patients. The frequency of hyperglycemic episodes increased after injection, but the proportions of patients with at least 1 hyperglycemic episode before and after injection were not significantly different.These results suggest that local corticosteroid injections are a clinically safe treatment option for inflammatory processes of the hand and wrist in patients with diabetes mellitus. On average, patients experienced slight increases in blood glucose after receiving an injection. Most experienced isolated increases substantially beyond baseline and isolated hyperglycemic effects, but these did not pose an apparent clinical risk. PMID:23218632

  13. Detection of protein biomarker using a blood glucose meter.

    Science.gov (United States)

    Lan, Tian; Xiang, Yu; Lu, Yi

    2015-01-01

    mHeath technologies are recognized to play important roles in the future of personal care and medicine. However, their full potentials have not been reached, as most of current technologies are restricted to monitoring physical and behavioral parameters, such as body temperature, heart rate, blood pressure, and physical movement, while direct monitoring of biomarkers in body fluids can provide much more accurate and useful information for medical diagnostics. A major barrier to realizing the full potential of mHealth is the high costs and long cycles of developing mHealth devices capable of monitoring biomarkers in body fluids. To lower the costs and shorten the developmental cycle, we have demonstrated the leveraging of the most successful portable medical monitoring device on the market, the blood glucose meter (BGM), with FDA-approved smartphone technologies that allow for wireless transmission and remote monitoring of a wide range of non-glucose targets. In this protocol, an aptamer-based assay for quantification of interferon-γ (IFN-γ) using an off-the-shelf BGM is described. In this assay, an aptamer-based target recognition system is employed. When IFN-γ binds to the aptamer, it triggers the release of a reporter enzyme, invertase, which can catalyze the conversion of sucrose (not detected by BGM) to glucose. The glucose being produced is then detected using a BGM. The system mimics a competitive enzyme-linked immunosorbent assay (ELISA), where the traditional immunoassay is replaced by an aptamer binding assay; the reporter protein is replaced by invertase, and finally the optical or fluorescence detector is replaced with widely available BGMs. PMID:25626534

  14. Capillary bedside blood glucose measurement in neonates: missing a diagnosis of galactosemia.

    Science.gov (United States)

    Özbek, Mehmet Nuri; Öcal, Murat; Tanrıverdi, Sibel; Baysal, Birsen; Deniz, Ahmet; Öncel, Kahraman; Demirbilek, Hüseyin

    2015-03-01

    A number of factors may lead to inaccuracy in measurement of capillary blood glucose with a glucometer. Measurement of other carbohydrate molecules such as galactose and fructose along with glucose can potentially be a cause of error. We report a newborn patient who was referred to our hospital with conjugated bilirubinemia, hepatomegaly and high capillary blood glucose levels measured with a glucometer. Simultaneous biochemical measurements revealed normal blood glucose levels. Further investigation led to a diagnosis of classical galactosemia. Capillary blood glucose level measured with glucometer also dropped to normal values following cessation of breastfeeding and initiation of feeding with a lactose-free formula. PMID:25800483

  15. BASELINE LEVELS OF TRACE METALS IN BLOOD OF CAPTIVE ASIAN ELEPHANTS (ELEPHAS MAXIMUS)

    OpenAIRE

    Wiedner, Ellen B.; Takeuchi, Noel Y.; Isaza, Ramiro; Barber, David

    2011-01-01

    Whole blood from 33 healthy captive Asian elephants (Elephas maximus) was analyzed for 12 trace elements: aluminum, chromium, manganese, cobalt, nickel, copper, zinc, arsenic, selenium, cadmium, mercury, and lead for the purpose of estimating preliminary baseline population parameters for these minerals. Metals were quantified by inductively coupled plasma mass spectroscopy. Baseline ranges for all animals and for all trace elements were comparable to normal concentrations reported in other s...

  16. [Research of Outlier Samples Elimination Methods for Near-Infrared Spectral Analysis of Blood Glucose].

    Science.gov (United States)

    Lin, Yongzhong; Li, Lina; Lin, Tianliang

    2015-12-01

    For the near-infrared (NIR) spectral analysis of the concentration of blood glucose, the calibration accuracy can be affected because of the existing of outlier samples. In this research, a Monte-Carlo cross validation (MCCV) method is constructed for eliminating outlier samples. The human blood plasma experiment in vitro and the human body experiment in vivo were introduced to evaluate the MCCV method for its application effect in NIR spectral analysis of blood glucose. And the uninformative sample elimination method based on modified uninformative variable elimination (MUVE-USE) was employed in this study for the comparison with MCCV. The results indicated that, like the MUVE-USE method, the outlier samples elimination method based on MCCV could be used to eliminate the outlier samples which came from gross errors (such as bad sample) or system errors (such as baseline drift). In addition, the outlier samples from the random errors of uncertain causes which affect model accuracy can be eliminated simultaneously by MCCV. The elimination of multiple outlier samples is beneficial to the improvement of prediction accuracy of calibration model. PMID:27079108

  17. Modeling and Measurement of Correlation between Blood and Interstitial Glucose Changes

    Science.gov (United States)

    Shi, Ting; Li, Dachao; Li, Guoqing; Zhang, Yiming; Xu, Kexin; Lu, Luo

    2016-01-01

    One of the most effective methods for continuous blood glucose monitoring is to continuously measure glucose in the interstitial fluid (ISF). However, multiple physiological factors can modulate glucose concentrations and affect the lag phase between blood and ISF glucose changes. This study aims to develop a compensatory tool for measuring the delay in ISF glucose variations in reference to blood glucose changes. A theoretical model was developed based on biophysics and physiology of glucose transport in the microcirculation system. Blood and interstitial fluid glucose changes were measured in mice and rats by fluorescent and isotope methods, respectively. Computer simulation mimicked curves were fitted with data resulting from fluorescent measurements of mice and isotope measurements of rats, indicating that there were lag times for ISF glucose changes. It also showed that there was a required diffusion distance for glucose to travel from center of capillaries to interstitial space in both mouse and rat models. We conclude that it is feasible with the developed model to continuously monitor dynamic changes of blood glucose concentration through measuring glucose changes in ISF with high accuracy, which requires correct parameters for determining and compensating for the delay time of glucose changes in ISF.

  18. Baseline blood levels of manganese, lead, cadmium, copper, and zinc in residents of Beijing suburb

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Long-Lian, E-mail: Longlian57@163.com [Department of Occupational Diseases Control and Prevention, Fengtai Center for Disease Control and Prevention, Beijing 100071 (China); Lu, Ling [Department of Occupational Diseases Control and Prevention, Fengtai Center for Disease Control and Prevention, Beijing 100071 (China); Pan, Ya-Juan; Ding, Chun-Guang [Institute for Occupational Health and Poison Control in China Center for Disease Prevention and Control, Beijing 100050 (China); Xu, Da-Yong [Department of Occupational Diseases Control and Prevention, Fengtai Center for Disease Control and Prevention, Beijing 100071 (China); Huang, Chuan-Feng; Pan, Xing-Fu [Institute for Occupational Health and Poison Control in China Center for Disease Prevention and Control, Beijing 100050 (China); Zheng, Wei, E-mail: wzheng@purdue.edu [School of Health Sciences, Purdue University, West Lafayette, IN 47907 (United States)

    2015-07-15

    Baseline blood concentrations of metals are important references for monitoring metal exposure in environmental and occupational settings. The purpose of this study was to determine the blood levels of manganese (Mn), copper (Cu), zinc (Zn), lead (Pb), and cadmium (Cd) among the residents (aged 12–60 years old) living in the suburb southwest of Beijing in China and to compare the outcomes with reported values in various developed countries. Blood samples were collected from 648 subjects from March 2009 to February 2010. Metal concentrations in the whole blood were determined by ICP-MS. The geometric means of blood levels of Mn, Cu, Zn, Pb and Cd were 11.4, 802.4, 4665, 42.6, and 0.68 µg/L, respectively. Male subjects had higher blood Pb than the females, while the females had higher blood Mn and Cu than the males. There was no gender difference for blood Cd and Zn. Smokers had higher blood Cu, Zn, and Cd than nonsmokers. There were significant age-related differences in blood levels of all metals studied; subjects in the 17–30 age group had higher blood levels of Mn, Pb, Cu, and Zn, while those in the 46–60 age group had higher Cd than the other age groups. A remarkably lower blood level of Cu and Zn in this population as compared with residents of other developed countries was noticed. Based on the current study, the normal reference ranges for the blood Mn were estimated to be 5.80–25.2 μg/L; for blood Cu, 541–1475 μg/L; for blood Zn, 2349–9492 μg/L; for blood Pb, <100 μg/L; and for blood Cd, <5.30 μg/L in the general population living in Beijing suburbs. - Highlights: • Baseline blood levels of metals in residents of Beijing suburb are investigated. • BMn and BPb in this cohort are higher than those in other developed countries. • Remarkably lower blood levels of Cu and Zn in this Chinese cohort are noticed. • The reference values for blood levels of Mn, Cu, Zn, Pb, and Cd are established.

  19. Baseline blood levels of manganese, lead, cadmium, copper, and zinc in residents of Beijing suburb

    International Nuclear Information System (INIS)

    Baseline blood concentrations of metals are important references for monitoring metal exposure in environmental and occupational settings. The purpose of this study was to determine the blood levels of manganese (Mn), copper (Cu), zinc (Zn), lead (Pb), and cadmium (Cd) among the residents (aged 12–60 years old) living in the suburb southwest of Beijing in China and to compare the outcomes with reported values in various developed countries. Blood samples were collected from 648 subjects from March 2009 to February 2010. Metal concentrations in the whole blood were determined by ICP-MS. The geometric means of blood levels of Mn, Cu, Zn, Pb and Cd were 11.4, 802.4, 4665, 42.6, and 0.68 µg/L, respectively. Male subjects had higher blood Pb than the females, while the females had higher blood Mn and Cu than the males. There was no gender difference for blood Cd and Zn. Smokers had higher blood Cu, Zn, and Cd than nonsmokers. There were significant age-related differences in blood levels of all metals studied; subjects in the 17–30 age group had higher blood levels of Mn, Pb, Cu, and Zn, while those in the 46–60 age group had higher Cd than the other age groups. A remarkably lower blood level of Cu and Zn in this population as compared with residents of other developed countries was noticed. Based on the current study, the normal reference ranges for the blood Mn were estimated to be 5.80–25.2 μg/L; for blood Cu, 541–1475 μg/L; for blood Zn, 2349–9492 μg/L; for blood Pb, <100 μg/L; and for blood Cd, <5.30 μg/L in the general population living in Beijing suburbs. - Highlights: • Baseline blood levels of metals in residents of Beijing suburb are investigated. • BMn and BPb in this cohort are higher than those in other developed countries. • Remarkably lower blood levels of Cu and Zn in this Chinese cohort are noticed. • The reference values for blood levels of Mn, Cu, Zn, Pb, and Cd are established

  20. DIASTOLIC BLOOD PRESSURE OR ACTUALLY IT IS BASELINE SYSTOLIC BLOOD PRESSURE?

    OpenAIRE

    R.Vinodh Rajkumar

    2015-01-01

    Blood pressure measuring represents a routine investigation in general medicine. Nokolai Korotkoff was only 31 years old when he made a short presentation to the Scientific Meeting of the Military Hospital of the Academy on 5 November 1905 concerning an easy non-invasive method of blood pressure (BP) measurement, entitled ‘Concerning the problems of the methods of blood pressure measurement’. If the pressure in the cuff is relieved, blood starts coming through the compressed arterial segment...

  1. A Simple Laboratory Experiment to Determine the Kinetics of Mutarotation of D-Glucose Using a Blood Glucose Meter

    Science.gov (United States)

    Perles, Carlos E.; Volpe, Pedro L. O.

    2008-01-01

    A simple commercial blood glucose meter is used to follow the kinetics of mutarotation of D-glucose in aqueous solution. The results may be compared with those obtained using an automatic polarimeter, if this is available This experiment is proposed for use by students in a general chemistry, biology, organic chemistry, and physical chemistry…

  2. Early blood glucose profile and neurodevelopmental outcome at two years in neonatal hypoxic-ischaemic encephalopathy

    OpenAIRE

    Dempsey Eugene M; Boylan Geraldine B; Murray Deirdre M; Nadeem Montasser; Ryan Cornelius A

    2011-01-01

    Abstract Background To examine the blood glucose profile and the relationship between blood glucose levels and neurodevelopmental outcome in term infants with hypoxic-ischaemic encephalopathy. Methods Blood glucose values within 72 hours of birth were collected from 52 term infants with hypoxic-ischaemic encephalopathy. Hypoglycaemia [ 150 mg/dL (8.3 mmol/L)] were correlated to neurodevelopmental outcome at 24 months of age. Results Four fifths ...

  3. EFFECT OF FIBER SUPPLEMENT ON BLOOD GLUCOSE LEVEL OF NIDDM SUBJECTS

    OpenAIRE

    Seema V Medhe* and Mangal V Medhe

    2013-01-01

    An investigation was undertaken to assess effect of fiber rich supplement on blood glucose level of type 2 diabetic patients. Fiber rich supplement was tested on eleven type 2 diabetic subjects for blood glucose lowering effect by undertaking an intervention of two months feeding trials. Results with respect to two months supplementation indicated that the fiber rich supplement was helpful in significantly reducing the fasting and postprandial blood glucose level of subjects. The reduction in...

  4. Age-related memory impairments due to reduced blood glucose responses to epinephrine

    OpenAIRE

    Morris, Ken A.; Chang, Qing; Mohler, Eric G.; Gold, Paul E.

    2009-01-01

    Increases in blood glucose levels are an important component of the mechanisms by which epinephrine enhances memory formation. The present experiments addressed the hypothesis that a dysfunction in the blood glucose response to circulating epinephrine contributes to age-related memory impairments. Doses of epinephrine and glucagon that significantly increased blood glucose levels in young adult rats were far less effective at doing so in two-year-old rats. In young rats, epinephrine and gluco...

  5. The Effects of Blood Glucose Levels on Cognitive Performance: A Review of the Literature

    Science.gov (United States)

    Feldman, Jolene; Barshi, Immanuel

    2007-01-01

    The purpose of this review paper is to discuss the research literature on the effects of blood glucose levels on executive and non-executive functions in humans. The review begins with a brief description of blood glucose, how it has been studied, previous syntheses of prior studies, and basic results regarding the role of blood glucose on cognitive functioning. The following sections describe work that investigated the effect of blood glucose on both non-executive and executive functions (e.g., sensory processing, psychomotor functioning, attention, vigilance, memory, language and communication, judgement and decision-making, and complex task performance). Within each section, summaries of the findings and challenges to the literature are included. Measurement conversions of blood glucose levels, blood glucose values, and associated symptoms are depicted. References to the types of tests used to investigate blood glucose and cognitive performance are provided. For more detailed descriptions of references within (and in addition to) this paper, an annotated bibliography is also provided. Several moderator variables including individual differences and contextual variables related to the effects of blood glucose levels on performance (e.g., age, gender, time of day, familiarity with the task and symptom awareness, expectancy effects, dose dependent effects, time dependent effects, task specific effects, rising and falling blood glucose levels, and speed and/or accuracy trade-offs) are addressed later in the paper. Some suggestions for future experimental methodologies are also made.

  6. A comprehensive compartmental model of blood glucose regulation for healthy and type 2 diabetic subjects

    DEFF Research Database (Denmark)

    Vahidi, O; Kwok, K E; Gopaluni, R B;

    2016-01-01

    We have expanded a former compartmental model of blood glucose regulation for healthy and type 2 diabetic subjects. The former model was a detailed physiological model which considered the interactions of three substances, glucose, insulin and glucagon on regulating the blood sugar. The main...... drawback of the former model was its restriction on the route of glucose entrance to the body which was limited to the intravenous glucose injection. To handle the oral glucose intake, we have added a model of glucose absorption in the gastrointestinal tract to the former model to address the resultant...... variations of blood glucose concentrations following an oral glucose intake. Another model representing the incretins production in the gastrointestinal tract along with their hormonal effects on boosting pancreatic insulin production is also added to the former model. We have used two sets of clinical data...

  7. Application of transcutaneous diffuse reflectance spectroscopy in the measurement of blood glucose concentration

    Institute of Scientific and Technical Information of China (English)

    Wenliang Chen(陈文亮); Rong Liu(刘蓉); Houxin Cui(崔厚欣); Kexin Xu(徐可欣); Lina Lü(吕丽娜)

    2004-01-01

    In this paper, the propagation characteristics of near-infrared (NIR) light in the palm tissue are analyzed,and the principle and feasibility of using transcutaneous diffuse reflectance spectroscopy for non-invasive blood glucose detection are presented. An optical probe suitable for measuring the diffuse reflectance spectrum of human palm and a non-invasive blood glucose detection system using NIR spectroscopy are designed. Based on this system, oral glucose tolerance tests are performed to measure the blood glucose concentrations of two young healthy volunteers. The partial least square calibration model is then constructed by all individual experimental data. The final result shows that correlation coefficients of the two experiments between the predicted blood glucose concentrations and the reference blood glucose concentrations are 0.9870 and 0.9854, respectively. The root mean square errors of prediction of full cross validation are 0.54 and 0.52 mmol/1, respectively.

  8. Parsimonious model for blood glucose level monitoring in type 2 diabetes patients.

    Science.gov (United States)

    Zhao, Fang; Ma, Yan Fen; Wen, Jing Xiao; DU, Yan Fang; Li, Chun Lin; Li, Guang Wei

    2014-07-01

    To establish the parsimonious model for blood glucose monitoring in patients with type 2 diabetes receiving oral hypoglycemic agent treatment. One hundred and fifty-nine adult Chinese type 2 diabetes patients were randomized to receive rapid-acting or sustained-release gliclazide therapy for 12 weeks. Their blood glucose levels were measured at 10 time points in a 24 h period before and after treatment, and the 24 h mean blood glucose levels were measured. Contribution of blood glucose levels to the mean blood glucose level and HbA1c was assessed by multiple regression analysis. The correlation coefficients of blood glucose level measured at 10 time points to the daily MBG were 0.58-0.74 and 0.59-0.79, respectively, before and after treatment (P<0.0001). The multiple stepwise regression analysis showed that the blood glucose levels measured at 6 of the 10 time points could explain 95% and 97% of the changes in MBG before and after treatment. The three blood glucose levels, which were measured at fasting, 2 h after breakfast and before dinner, of the 10 time points could explain 84% and 86% of the changes in MBG before and after treatment, but could only explain 36% and 26% of the changes in HbA1c before and after treatment, and they had a poorer correlation with the HbA1c than with the 24 h MBG. The blood glucose levels measured at fasting, 2 h after breakfast and before dinner truly reflected the change 24 h blood glucose level, suggesting that they are appropriate for the self-monitoring of blood glucose levels in diabetes patients receiving oral anti-diabetes therapy. PMID:25073916

  9. Dietary thylakoids suppress blood glucose and modulate appetite-regulating hormones in pigs exposed to oral glucose tolerance test

    DEFF Research Database (Denmark)

    Montelius, Caroline; Szwiec, Katarzyna; Kardas, Marek;

    2014-01-01

    , either with or without addition of 0.5 g/kg body weight of thylakoid powder. RESULTS: The supplementation of thylakoids to the oral glucose tolerance test resulted in decreased blood glucose concentrations during the first hour, increased plasma cholecystokinin concentrations during the first two hours......BACKGROUND & AIMS: Dietary chloroplast thylakoids have previously been found to reduce food intake and body weight in animal models, and to change metabolic profiles in humans in mixed-food meal studies. The aim of this study was to investigate the modulatory effects of thylakoids on glucose...... metabolism and appetite-regulating hormones during an oral glucose tolerance test in pigs fed a high fat diet. METHODS: Six pigs were fed a high fat diet (36 energy% fat) for one month before oral glucose tolerance test (1 g/kg d-glucose) was performed. The experiment was designed as a cross-over study...

  10. 75 FR 2549 - Clinical Accuracy Requirements for Point of Care Blood Glucose Meters; Public Meeting; Request...

    Science.gov (United States)

    2010-01-15

    ...) Clinical accuracy for blood glucose meters, (2) tight glycemic control in clinical settings, and (3... allow for better glycemic control by diabetics than in the past. Glucose meters are not only used by... evaluated by FDA. For example, glucose meters are increasingly being used to achieve tight glycemic...

  11. Elective Percutaneous Coronary Intervention: The Relationship between Preprocedural Blood Glucose Levels and Periprocedural Myocardial Injury

    OpenAIRE

    Madani, Mohsen; Alizadeh, Keivan; Ghazaee, Sepideh Parchami; Zavarehee, Abbas; Abdi, Seifollah; Shakerian, Farshad; salehi, Negar; Firouzi, Ata

    2013-01-01

    Regardless of the diabetic status of patients with coronary artery disease, hyperglycemia and hypoglycemia are adversely associated with cardiovascular events. The relationship between glucose levels and increased mortality risk in acute myocardial infarction has been shown through various glucose metrics; however, there is a dearth of multivariate analysis of the relationship between elective coronary angioplasty and preprocedural blood glucose levels.

  12. Effects of Gongronema latifolium on blood lipids, lipoproteins and glucose values in adult Nigerians

    Directory of Open Access Journals (Sweden)

    Rosemary Adamma Analike

    2015-04-01

    Full Text Available Background: The study evaluates the beneficial effects or otherwise of Gongronema latifolium (utazi consumption on plasma lipid profile and blood glucose in healthy subjects. Methods: The study was conducted on twenty (20 apparently healthy subjects (10 males and 10 females, within the age range of 20-55years who were randomly recruited from Nnamdi Azikiwe University Teaching Hospital (NAUTH staff and medical students in Nnewi Campus. Twenty experimental subjects (10 males and 10 females were fed with 5g/day of fresh Gongronema latifolium leaves for six weeks. Blood samples were collected at baseline and every week for six weeks and the biochemical parameters analyzed using standard laboratory methods. Results: There were significant reductions in the levels of plasma glucose (3.85 +/- 0.14 vs. 4.92 +/- 0.31 mmol/l, cholesterol (3.60 +/- 0.43 vs. 4.56 +/- 0.67 mmol/l, triglycerides (0.73 +/- 0.19 vs. 0.96 +/- 0.20 mmol/l, Low Density Lipoprotein Cholesterol (LDL-C (1.97 +/- 0.48 vs. 2.70 +/- 0.67 mmol/l and LDL-C/High Density Lipoprotein Cholesterol (HDL-C ratio (1.32 +/- 0.44 vs. 2.11 +/- 0.72 mmol/l of the subjects that were fed with Gongronema latifolium leaves for six weeks compared with their baseline values; all P <0.05. Conclusion: The result of this study showed that Gongronema latifolium has hypoglycemic and hypolipidemic effect on healthy subjects and might be beneficial for the management of diabetes mellitus and cardiovascular diseases. [Int J Res Med Sci 2015; 3(4.000: 891-895

  13. Carbon dot based non enzymatic approach for the detection and estimation of glucose in blood serum

    Science.gov (United States)

    Shanti Krishna, A.; Nair, Priya A.; Radhakumary, C.; Sreenivasan, K.

    2016-05-01

    In this study we generated a simple, reliable and selective approach based on carbon dots (CDs) and 4-cyanophenylboronic acid (CPBA) for blood glucose sensing. The methodology relies on the quenching of the emission of CDs by CPBA followed by its recovery by glucose. The system consisting of CDs and CPBA was characterised by Fourier transform infra red spectrum, transmissions electron microscopic, dynamic light scattering instrument, UV–visible and fluorescence techniques. The response of the probe, CD-BA in presence of different concentrations of glucose was assessed. Linear range was obtained for glucose concentrations ranging from 1 to 30 mM. Interferences by other saccharides and various biomolecules coexisting in blood serum were negligible. The chemo sensor thus developed has been successfully used for the estimation of glucose in human blood serum. The system being sensitive, efficient and easy to perform is a promising platform for blood glucose sensing.

  14. Self-monitoring of tear glucose: the development of a tear based glucose sensor as an alternative to self-monitoring of blood glucose.

    Science.gov (United States)

    La Belle, Jeffrey T; Adams, Anngela; Lin, Chi-En; Engelschall, Erica; Pratt, Breanna; Cook, Curtiss B

    2016-07-28

    Tear glucose sensing for diabetes management has long been sought as an alternative to more invasive self-monitoring of blood glucose (SMBG). However, tear glucose sensors were known to have limitations, including correlation issues with blood glucose due to low sample volume, low concentration of glucose in the tear fluid, and evaporation of the tear sample. An engineering design approach to solve these problems led to the development of an integrated device capable of collecting the tear sample from the ocular surface with little to no stress on the eye, with an extremely low limit of detection, broad dynamic range, and rapid detection and analysis of sample. Here we present the development of a prototypical self-monitoring of tear glucose (SMTG) sensor, summarizing bench studies on the enzymes and their specificity, the development of the fluid capture device and its manufacture and performance and results of system testing in an animal study where safety, lag time and tear glucose to blood glucose correlation were assessed. PMID:27327531

  15. A switching control strategy for the attenuation of blood glucose disturbances

    OpenAIRE

    Markakis, Mihalis G.; Mitsis, Georgios D.; Papavassilopoulos, George P.; Ioannou, Petros A.; Marmarelis, Vasilis Z.

    2011-01-01

    In this computational study we consider a generalized minimal model structure for the intravenously infused insulin–blood glucose dynamics, which can represent a wide variety of diabetic patients, and augment this model structure with a glucose rate disturbance signal that captures the aggregate effects of various internal and external factors on blood glucose. Then we develop a model-based, switching controller, which attempts to balance between optimal performance, reduced computational com...

  16. Dielectric properties of glucose solutions in the millimetre-wave range and control of glucose content in blood

    Science.gov (United States)

    Meriakri, V. V.; Chigrai, E. E.; Kim, D.; Nikitin, I. P.; Pangonis, L. I.; Parkhomenko, M. P.; Won, J. H.

    2007-04-01

    The measurement of the dielectric properties of sugar solutions, as well as blood imitators and blood, in the millimetre-wave range allows one to obtain valuable information on the possibility of real-time control of glucose concentration in blood. These measurements are also of interest for other applications, for example in the wine industry and for the determination of water content in oil, oil products and other liquids.

  17. A Meta-Analysis of Blood Glucose Effects on Human Decision Making

    DEFF Research Database (Denmark)

    Orquin, Jacob Lund; Kurzban, Robert

    2016-01-01

    identified 42 studies relating to 4 dimensions of decision making: willingness to pay, willingness to work, time discounting, and decision style. We did not find a uniform influence of blood glucose on decision making. Instead, we found that low levels of blood glucose increase the willingness to pay and...... willingness to work when a situation is food related, but decrease willingness to pay and work in all other situations. Low levels of blood glucose increase the future discount rate for food; that is, decision makers become more impatient, and to a lesser extent increase the future discount rate for money....... Low levels of blood glucose also increase the tendency to make more intuitive rather than deliberate decisions. However, this effect was only observed in situations unrelated to food. We conclude that blood glucose has domain-specific effects, influencing decision making differently depending on the...

  18. Blood glucose distribution and prevalence of diabetes in Hanoi (Vietnam).

    Science.gov (United States)

    Quoc, P S; Charles, M A; Cuong, N H; Lieu, L H; Tuan, N A; Thomas, M; Balkau, B; Simon, D

    1994-04-01

    Few epidemiologic surveys have been performed to assess the prevalence of diabetes in representative samples, and few data are available on the epidemiologic features of diabetes in Southeast Asia. We report the results of a 1990 study performed in the Hanoi area (Vietnam) on 4,912 subjects (95.0% of the eligible population), aged 15 years or over, selected by a stratified random cluster procedure using the 1989 census list. A two-step design was used: 1) screening for diabetes by measuring capillary blood glucose (CBG) before dinner with a Glucometer II device; and 2) for subjects with a CBG measurement of > or = 105 mg/dl, a diagnostic test on the following morning, using a 75-g oral glucose tolerance test and World Health Organization criteria (93.9% of the positive screenees took this test). CBG values before dinner were unimodally distributed and skewed to the right, increasing with age in both sexes. Women had a significantly higher level of age-adjusted CBG than did men before dinner (p or = 27 kg/m2. The subjects living in the urban areas had higher levels of fasting and 2-hour CBG and a higher diabetes prevalence than did the rural inhabitants (relative risk = 1.3; 95% CI 1.04-3.23). Diabetes appears to be a rare disease in the Hanoi area (1.4% for subjects aged 30-64 years, after age standardization using the Segi distribution), affecting women two times as often as men. Typical insulin-dependent (type I) or obese non-insulin-dependent (type II) diabetes mellitus patients are uncommon. PMID:8166132

  19. Blood Glucose Control Using a Novel Continuous Blood Glucose Monitor and Repetitive Intravenous Insulin Boluses: Exploiting Natural Insulin Pulsatility as a Principle for a Future Artificial Pancreas

    Directory of Open Access Journals (Sweden)

    Nils K. Skjaervold

    2013-01-01

    Full Text Available The aim of this study was to construct a glucose regulatory algorithm by employing the natural pulsatile pattern of insulin secretion and the oscillatory pattern of resting blood glucose levels and further to regulate the blood glucose level in diabetic pigs by this method. We developed a control algorithm based on repetitive intravenous bolus injections of insulin and combined this with an intravascular blood glucose monitor. Four anesthetized pigs were used in the study. The animals developed a mildly diabetic state from streptozotocin pretreatment. They were steadily brought within the blood glucose target range of 4.5–6.0 mmol/L in 21 to 121 min and kept within that range for 128 to 238 min (hypoglycemic values varied from 2.9 to 51.1 min. The study confirmed our hypotheses regarding the feasibility of this new principle for blood glucose control, and the algorithm was constantly improved during the study to produce the best results in the last animals. The main obstacles were the drift of the IvS-1 sensor and problems with the calibration procedure, which calls for an improvement in the sensor stability before this method can be applied fully in new studies in animals and humans.

  20. THE EFFECT OF AVOCADO (PERSEA AMERICANA MILL.) LEAVES EXTRACT TOWARDS THE MOUSE'S BLOOD GLUCOSE DECREASE WITH THE GLUCOSE TOLERANCE METHOD

    OpenAIRE

    Shirly Kumala*, Hesty Utami and Wahyu Kartika Sari

    2013-01-01

    Decrease in blood glucose level test with the use of oral glucose tolerance method from Avocado leaves was carried out. Swiss Webster male mice were divided randomly into five groups. They were negative control, positive control (Glipizide 0.013 mg/20 g BW) and three test groups treated with dosage of avocado leaves ethanol extract 0.490 g/kg, 0.980 g/kg and 1.960 g /BW respectively. Experiment was begun with feeding the mice with the test solution followed by feeding glucose solution (1.5 g/...

  1. Pulsed photoacoustic techniques and glucose determination in human blood and tissue

    OpenAIRE

    Zhao, Z.

    2002-01-01

    Abstract Determination of blood glucose level is a frequently occurring procedure in diabetes care. As the most common method involves collecting blood drops for chemical analysis, it is invasive and liable to afflict a degree of pain and cause a skin injury. To eliminate these disadvantages, this thesis focuses on pulsed photoacoustic techniques, which have potential ability in non-invasive blood glucose measurement. The fundamental theory of photoacoustics in liquid and soft tissue ...

  2. Evaluation of the Capillary Blood Glucose Self-monitoring Program

    Directory of Open Access Journals (Sweden)

    Mariana Cristina Augusto

    2014-10-01

    Full Text Available OBJECTIVE: to evaluate the structure, process and results of the Capillary Blood Glucose Self-monitoring Program in a Brazilian city.METHOD: epidemiological, cross-sectional study. The methodological framework of Donabedian was used to construct indicators of structure, process and outcome. A random sample (n = 288 of users enrolled and 96 health professionals who worked in the program was studied. Two questionnaires were used that were constructed for this study, one for professionals and one for users, both containing data for the evaluation of structure, process and outcome. Anthropometric measures and laboratory results were collected by consulting the patients' health records. The analysis involved descriptive statistics.RESULTS: most of the professionals were not qualified to work in the program and were not knowledgeable about the set of criteria for patient registration. None of the patients received complete and correct orientations about the program and the percentage with skills to perform conducts autonomously was 10%. As regards the result indicators, 86.4% of the patients and 81.3% of the professionals evaluated the program positively.CONCLUSION: the evaluation indicators designed revealed that one of the main objectives of the program, self-care skills, has not been achieved.

  3. Effect and potential mechanism of action of sea cucumber saponins on postprandial blood glucose in mice.

    Science.gov (United States)

    Fu, Xueyuan; Wen, Min; Han, Xiuqing; Yanagita, Teruyoshi; Xue, Yong; Wang, Jingfeng; Xue, Changhu; Wang, Yuming

    2016-06-01

    Postprandial blood glucose control is the major goal in the treatment of diabetes. Here, we investigated the effect of sea cucumber saponins (SCSs) on postprandial blood glucose levels. SCS inhibited yeast as well as rat intestinal α-glucosidase activity in a dose-dependent manner and showed better inhibition of yeast α-glucosidases compared to the positive control. Further studies were performed using ICR mice treated with SCS and starch or SCS alone by oral gavage. Unexpectedly, SCS increased postprandial blood glucose levels a short time (1 h) after oral gavage. The serum corticosterone (CORT) level showed a consistent correlation with glucose levels. In vitro experiments confirmed that SCS treatment increased the secretion of CORT in the Y1 adrenal cell line. Overall, these studies demonstrated that SCS gavage could inhibit α-glucosidase activity but cannot attenuate postprandial blood glucose level within short time periods. The underlying mechanisms are probably related to increased serum CORT levels. PMID:26932154

  4. High activity enables life on a high-sugar diet: blood glucose regulation in nectar-feeding bats

    OpenAIRE

    Kelm, Detlev H.; Simon, Ralph; Kuhlow, Doreen; Voigt, Christian C.; Ristow, Michael

    2011-01-01

    High blood glucose levels caused by excessive sugar consumption are detrimental to mammalian health and life expectancy. Despite consuming vast quantities of sugar-rich floral nectar, nectar-feeding bats are long-lived, provoking the question of how they regulate blood glucose. We investigated blood glucose levels in nectar-feeding bats (Glossophaga soricina) in experiments in which we varied the amount of dietary sugar or flight time. Blood glucose levels increased with the quantity of gluco...

  5. The Food and Drug Administration Is Now Preparing to Establish Tighter Performance Requirements for Blood Glucose Monitors

    OpenAIRE

    Klonoff, David C.

    2010-01-01

    On March 16 and 17, 2010, the Food and Drug Administration (FDA) presented a public meeting about blood glucose monitoring at the Gaithersberg Hilton Hotel. The meeting was intended to present expert opinions and solicit input from the public about whether to develop new regulatory policies for blood glucose monitors. The meeting was divided into three sections: (1) Clinical Accuracy Requirements for Blood Glucose Monitors, (2) Interferences and Limitations of Blood Glucose Monitors, and (3) ...

  6. The Coupling of Cerebral Metabolic Rate of Glucose and Cerebral Blood Flow In Vivo

    DEFF Research Database (Denmark)

    Hasselbalch, Steen; Paulson, Olaf Bjarne

    2012-01-01

    The energy supplied to the brain by metabolic substrate is largely utilized for maintaining synaptic transmission. In this regulation cerebral blood flow and glucose consumption is tightly coupled as well in the resting condition as during activation. Quantification of cerebral blood flow and...... not used for aerobic metabolism. Although some of the excess glucose uptake can be explained by lactate production, this phenomenon can still not account for the excess glucose uptake. Thus, more complex metabolic patterns in the brain might be reflected in the excess glucose uptake during activation...

  7. Glucagon-like peptide-1 inhibits blood-brain glucose transfer in humans

    DEFF Research Database (Denmark)

    Lerche, Susanne; Brock, Birgitte; Rungby, Jørgen;

    2008-01-01

    demonstrated that a hormone involved in postprandial glucose regulation also limits glucose delivery to brain tissue and hence provides a possible regulatory mechanism for the link between plasma glucose and brain glucose. Because GLP-1 reduces glucose uptake across the intact blood-brain barrier at normal...... glycemia, GLP-1 may also protect the brain by limiting intracerebral glucose fluctuation when plasma glucose is increased.......OBJECTIVE: Glucagon-like peptide-1 (GLP-1) has many effects on glucose homeostasis, and GLP-1 receptors are broadly represented in many tissues including the brain. Recent research in rodents suggests a protective effect of GLP-1 on brain tissue. The mechanism is unknown. We therefore tested...

  8. Internet-Based Contingency Management to Improve Adherence with Blood Glucose Testing Recommendations for Teens with Type 1 Diabetes

    Science.gov (United States)

    Raiff, Bethany R.; Dallery, Jesse

    2010-01-01

    The current study used Internet-based contingency management (CM) to increase adherence with blood glucose testing to at least 4 times daily. Four teens diagnosed with Type 1 diabetes earned vouchers for submitting blood glucose testing videos over a Web site. Participants submitted a mean of 1.7 and 3.1 blood glucose tests per day during the 2…

  9. High glucose impairs superoxide production from isolated blood neutrophils

    DEFF Research Database (Denmark)

    Perner, A; Nielsen, S E; Rask-Madsen, J

    2003-01-01

    Superoxide (O(2)(-)), a key antimicrobial agent in phagocytes, is produced by the activity of NADPH oxidase. High glucose concentrations may, however, impair the production of O(2)(-) through inhibition of glucose-6-phosphate dehydrogenase (G6PD), which catalyzes the formation of NADPH. This stud...... measured the acute effects of high glucose or the G6PD inhibitor dehydroepiandrosterone (DHEA) on the production of O(2)(-) from isolated human neutrophils....

  10. Application of optical lens of a CD writer for detecting the blood glucose semi-invasively

    Science.gov (United States)

    Meshram, N. D.; Dahikar, P. B.

    2014-10-01

    Recent technological advancements in the photonics industry have led to a resurgence of interest in optical glucose sensing and to realistic progress toward the development of an optical glucose sensor. Such a sensor has the potential to significantly improve the quality of life for the estimated 16 million diabetics in this country by making routine glucose measurements more convenient. Currently over 100 small companies and universities are working to develop noninvasive or minimally invasive glucose sensing technologies, and optical methods play a large role in these efforts. It has become overwhelmingly clear that frequent monitoring and tight control of blood sugar levels are requisite for effective management of Diabetes mellitus and reduction of the complications associated with this disease. The pain and trouble associated with current "finger-stick" methods for blood glucose monitoring result in decreased patient compliance and a failure to control blood sugar levels. Thus, the development of a convenient noninvasive blood glucose monitor holds the potential to significantly reduce the morbidity and mortality associated with Diabetes. A method and apparatus for noninvasive measurement of blood glucose concentration based on transilluminated laser beam via the Index Finger has been reported in this paper. This method depends on photodiode based laser operating at 632.8 nm wavelength. During measurement, the index finger is inserted into the glucose sensing unit, the transilluminated optical signal is converted into an electrical signal, compared with the reference electrical signal, and the obtained difference signal is processed by signal processing unit which presents the results in the form of blood glucose concentration. This method would enable the monitoring blood glucose level of the diabetic patient continuously, safely and noninvasively..

  11. Application of optical lens of a CD writer for detecting the blood glucose semi-invasively

    International Nuclear Information System (INIS)

    Recent technological advancements in the photonics industry have led to a resurgence of interest in optical glucose sensing and to realistic progress toward the development of an optical glucose sensor. Such a sensor has the potential to significantly improve the quality of life for the estimated 16 million diabetics in this country by making routine glucose measurements more convenient. Currently over 100 small companies and universities are working to develop noninvasive or minimally invasive glucose sensing technologies, and optical methods play a large role in these efforts. It has become overwhelmingly clear that frequent monitoring and tight control of blood sugar levels are requisite for effective management of Diabetes mellitus and reduction of the complications associated with this disease. The pain and trouble associated with current “finger-stick” methods for blood glucose monitoring result in decreased patient compliance and a failure to control blood sugar levels. Thus, the development of a convenient noninvasive blood glucose monitor holds the potential to significantly reduce the morbidity and mortality associated with Diabetes. A method and apparatus for noninvasive measurement of blood glucose concentration based on transilluminated laser beam via the Index Finger has been reported in this paper. This method depends on photodiode based laser operating at 632.8 nm wavelength. During measurement, the index finger is inserted into the glucose sensing unit, the transilluminated optical signal is converted into an electrical signal, compared with the reference electrical signal, and the obtained difference signal is processed by signal processing unit which presents the results in the form of blood glucose concentration. This method would enable the monitoring blood glucose level of the diabetic patient continuously, safely and noninvasively.

  12. Application of optical lens of a CD writer for detecting the blood glucose semi-invasively

    Energy Technology Data Exchange (ETDEWEB)

    Meshram, N. D., E-mail: meshramnileshsd@gmail.com [Mathuradas Mohota College of Sciences, Nagpur-440009 (India); Dahikar, P. B., E-mail: pbdahikar@rediffmail.com [Kamla Nehru Mahavidyalaya, Sakkardara Square, Nagpur-440009 (India)

    2014-10-15

    Recent technological advancements in the photonics industry have led to a resurgence of interest in optical glucose sensing and to realistic progress toward the development of an optical glucose sensor. Such a sensor has the potential to significantly improve the quality of life for the estimated 16 million diabetics in this country by making routine glucose measurements more convenient. Currently over 100 small companies and universities are working to develop noninvasive or minimally invasive glucose sensing technologies, and optical methods play a large role in these efforts. It has become overwhelmingly clear that frequent monitoring and tight control of blood sugar levels are requisite for effective management of Diabetes mellitus and reduction of the complications associated with this disease. The pain and trouble associated with current “finger-stick” methods for blood glucose monitoring result in decreased patient compliance and a failure to control blood sugar levels. Thus, the development of a convenient noninvasive blood glucose monitor holds the potential to significantly reduce the morbidity and mortality associated with Diabetes. A method and apparatus for noninvasive measurement of blood glucose concentration based on transilluminated laser beam via the Index Finger has been reported in this paper. This method depends on photodiode based laser operating at 632.8 nm wavelength. During measurement, the index finger is inserted into the glucose sensing unit, the transilluminated optical signal is converted into an electrical signal, compared with the reference electrical signal, and the obtained difference signal is processed by signal processing unit which presents the results in the form of blood glucose concentration. This method would enable the monitoring blood glucose level of the diabetic patient continuously, safely and noninvasively.

  13. The modulatory role of spinally located histamine receptors in the regulation of the blood glucose level in d-glucose-fed mice.

    Science.gov (United States)

    Sim, Yun-Beom; Park, Soo-Hyun; Kim, Sung-Su; Kim, Chea-Ha; Kim, Su-Jin; Lim, Su-Min; Jung, Jun-Sub; Ryu, Ohk-Hyun; Choi, Moon-Gi; Suh, Hong-Won

    2014-02-01

    The possible roles of spinal histamine receptors in the regulation of the blood glucose level were studied in ICR mice. Mice were intrathecally (i.t.) treated with histamine 1 (H1) receptor agonist (2-pyridylethylamine) or antagonist (cetirizine), histamine 2 (H2) receptor agonist (dimaprit) or antagonist (ranitidine), histamine 3 (H3) receptor agonist (α-methylhistamine) or antagonist (carcinine) and histamine 4 (H4) receptor agonist (VUF 8430) or antagonist (JNJ 7777120), and the blood glucose level was measured at 30, 60 and 120 min after i.t. administration. The i.t. injection with α-methylhistamine, but not carcinine slightly caused an elevation of the blood glucose level. In addition, histamine H1, H2, and H4 receptor agonists and antagonists did not affect the blood glucose level. In D-glucose-fed model, i.t. pretreatment with cetirizine enhanced the blood glucose level, whereas 2-pyridylethylamine did not affect. The i.t. pretreatment with dimaprit, but not ranitidine, enhanced the blood glucose level in D-glucose-fed model. In addition, α-methylhistamine, but not carcinine, slightly but significantly enhanced the blood glucose level D-glucose-fed model. Finally, i.t. pretreatment with JNJ 7777120, but not VUF 8430, slightly but significantly increased the blood glucose level. Although histamine receptors themselves located at the spinal cord do not exert any effect on the regulation of the blood glucose level, our results suggest that the activation of spinal histamine H2 receptors and the blockade of spinal histamine H1 or H3 receptors may play modulatory roles for up-regulation and down-regulation, respectively, of the blood glucose level in D-glucose fed model. PMID:24634595

  14. Effect of sucrose-containing snacks on blood glucose control.

    Science.gov (United States)

    Wise, J E; Keim, K S; Huisinga, J L; Willmann, P A

    1989-06-01

    To determine whether ingestion of sucrose-containing snacks would affect blood glucose (BG) control, 16 subjects with insulin-dependent diabetes mellitus participated in a 5-day double-blind study at a diabetes camp. Eight subjects in the sucrose group ate sucrose-sweetened snacks twice a day, and 8 subjects in the control group ingested snacks that were sweetened with aspartame. The percentage of total daily calories derived from added sucrose was 7% for the sucrose group and 1% for the control group. Metabolic control was assessed by daily capillary BG measurements obtained before meals and the bedtime snack and by determination of serum fructosamine (F) concentrations on arrival at camp (day 0) and after 5 days on the study protocol (day 5). No significant difference was seen between the groups on day 0 (sucrose group [mean +/- SD]: BG 9.9 +/- 3.6 mM, F 3.54 +/- 0.38 mM; control group: BG 9.1 +/- 2.8 mM, F 3.74 +/- 0.71 mM) or day 5 (sucrose group: BG 8.8 +/- 2.6 mM, F 2.94 +/- 0.32 mM; control group: BG 7.4 +/- 2.8 mM, F 2.92 +/- 0.59 mM). We conclude that ingestion of sucrose, added to snacks in an amount up to 7% of total energy intake, does not adversely affect short-term BG control. PMID:2659302

  15. Blood glucose fluctuation accelerates renal injury involved to inhibit the AKT signaling pathway in diabetic rats.

    Science.gov (United States)

    Ying, Changjiang; Zhou, Xiaoyan; Chang, Zhenzhen; Ling, Hongwei; Cheng, Xingbo; Li, Wei

    2016-07-01

    Blood glucose fluctuation is associated with diabetic nephropathy. However, the mechanism by which blood glucose fluctuation accelerates renal injury is not fully understood. The aim of the present study was to assess the effects of blood glucose fluctuation on diabetic nephropathy in rats and investigate its underlying mechanism. Diabetes in the rats was induced by a high sugar, high-fat diet, and a single dose of STZ (35 mg/kg)-injected intraperitoneally. Unstable blood sugar models were induced by subcutaneous insulin injection and intravenous glucose injection alternately. Body weight, glycosylated hemoglobin A1c (HbAlc), blood urea nitrogen (BUN), serum creatinine (Scr), and Creatinine clearance (Ccr) were assessed. T-SOD activity and MDA level were measured by assay kit. Change in renal tissue ultrastructure was observed by light microscopy and electron microscopy. Phosphorylated ser/thr protein kinase (p-AKT) (phosphor-Ser473), phosphorylated glycogen synthase kinase-3 beta (p-GSK-3β) (phosphor-Ser9), Bcl-2-associated X protein (BAX), B cell lymphoma/leukemia 2 (BCL-2), and cleaved-cysteinyl aspartate-specific proteinase-3 (caspase-3) levels were detected by immunohistochemistry and Western blot. We observed that BUN and Scr were increased in diabetic rats, and Ccr was decreased. Furthermore, blood glucose fluctuations could exacerbate the Ccr changes. Renal tissue ultrastructure was also seriously injured by glucose variability in diabetic rats. In addition, glucose fluctuation increased the oxidative stress of renal tissue. Moreover, fluctuating blood glucose decreased p-AKT level and BCL-2, and increased p-GSK-3β, BAX, cleaved-caspase-3 levels, and ratio of BAX/BCL-2 in the kidneys of diabetic rats. In conclusion, these results suggest that blood glucose fluctuation accelerated renal injury is due, at least in part to its oxidative stress promoting and inhibiting the AKT signaling pathway in diabetic rats. PMID:26860515

  16. Dextrose in the banked blood products does not seem to affect the blood glucose levels in patients undergoing liver transplantation

    OpenAIRE

    Cheng, Kwok-Wai; Chen, Chao-Long; Cheng, Yu-Fan; Tseng, Chia-Chih; Wang, Chih-Hsien; Chen, Yaw-Sen; Wang, Chih-Chi; Huang, Tung-Liang; Eng, Hock-Liew; Chiu, King-Wah; Wang, Shih-Hor; Lin, Chih-Che; Lin, Tsan-Shiun; Liu, Yueh-Wei; Jawan, Bruno

    2005-01-01

    AIM: Hyperglycemia commonly seen in liver transplantation (LT) has often been attributed to the dextrose in the storage solution of blood transfusion products. The purpose of the study is to compare the changes of the blood glucose levels in transfused and non-transfused patients during LT.

  17. Effect of pertussis toxin pretreated centrally on blood glucose level induced by stress.

    Science.gov (United States)

    Suh, Hong-Won; Sim, Yun-Beom; Park, Soo-Hyun; Sharma, Naveen; Im, Hyun-Ju; Hong, Jae-Seung

    2016-09-01

    In the present study, we examined the effect of pertussis toxin (PTX) administered centrally in a variety of stress-induced blood glucose level. Mice were exposed to stress after the pretreatment of PTX (0.05 or 0.1 µg) i.c.v. or i.t. once for 6 days. Blood glucose level was measured at 0, 30, 60 and 120 min after stress stimulation. The blood glucose level was increased in all stress groups. The blood glucose level reached at maximum level after 30 min of stress stimulation and returned to a normal level after 2 h of stress stimulation in restraint stress, physical, and emotional stress groups. The blood glucose level induced by cold-water swimming stress was gradually increased up to 1 h and returned to the normal level. The intracerebroventricular (i.c.v.) or intrathecal (i.t.) pretreatment with PTX, a Gi inhibitor, alone produced a hypoglycemia and almost abolished the elevation of the blood level induced by stress stimulation. The central pretreatment with PTX caused a reduction of plasma insulin level, whereas plasma corticosterone level was further up-regulated in all stress models. Our results suggest that the hyperglycemia produced by physical stress, emotional stress, restraint stress, and the cold-water swimming stress appear to be mediated by activation of centrally located PTX-sensitive G proteins. The reduction of blood glucose level by PTX appears to due to the reduction of plasma insulin level. The reduction of blood glucose level by PTX was accompanied by the reduction of plasma insulin level. Plasma corticosterone level up-regulation by PTX in stress models may be due to a blood glucose homeostatic mechanism. PMID:27610033

  18. The effect of euglucaemic hyperinsulinaemia on forearm blood flow and glucose uptake in the human forearm.

    Science.gov (United States)

    Fugmann, A; Lind, L; Andersson, P E; Millgård, J; Hänni, A; Berne, C; Lithell, H

    1998-12-01

    Insulin-mediated stimulation of blood flow to skeletal muscle has been proposed to be of major importance for insulin-mediated glucose uptake. The aim of this study was to investigate the relative importance of blood flow and glucose extraction as determinants of insulin-mediated glucose uptake in the human forearm. Forearm blood flow (FBF), glucose extraction and oxygen consumption were evaluated for 100 min during the euglycaemic hyperinsulinaemic clamp (92 mU/l) in nine healthy subjects. FBF was measured by venous occlusion plethysmography. Forearm glucose uptake increased sevenfold during the hyperinsulinaemia (P<0.001). Forearm glucose extraction showed a minor increase during the first 10 min of hyperinsulinaemia, but the most marked increase took place between 10 and 20 min (+170%). Thereafter, only a minor further increase was seen. During the first 10 min of hyperinsulinaemia FBF was unchanged. Thereafter, FBF increased steadily to a plateau reached after 60 min (+50%, P<0.001). A close relationship between whole body glucose uptake and FBF was seen at the end of the clamp (r = 0.75, P<0.02), but at this time the relationship between whole body glucose uptake and forearm glucose extraction was not significant. The modest increase in O2 consumption seen at the beginning of the clamp (+19%) was not related to FBF during the early phase of the clamp. In conclusion, the early course of insulin-mediated glucose uptake in the human forearm was mainly due to an increase in glucose extraction. However, with time the insulin-mediated increase in blood flow increased in importance and after 100 min of hyperinsulinaemia FBF was the major determinant of glucose uptake. PMID:9934819

  19. Impact of Epidemic Rates of Diabetes on the Chinese Blood Glucose Testing Market

    OpenAIRE

    Hu, Jamie; Zhang, Xian-En

    2011-01-01

    China has become the country with the largest diabetes mellitus population in the world since the 1990s. About 100 million diabetes cases have been diagnosed since 2008. Handheld blood glucose meters and test strips are urgently needed for daily patient measurement. The glucose monitor with a screen-printed carbon-based glucose electrode has been in commercial production since 1994. Since then, approximately 20 companies have been involved in manufacturing and marketing meters and test strips...

  20. Fingertip Blood Capillary Whole Blood Glucose and Venous Plasma Glucose test Results Contrast Analysis%指尖毛细血管全血糖与静脉血浆血糖检测结果对比分析

    Institute of Scientific and Technical Information of China (English)

    邢美荣

    2016-01-01

    Objective To compare the blood glucose and blood glucose in the blood glucose and blood glucose of the finger tip blood glucose and to explore the accuracy of blood glucose detection in the blood glucose of finger tip capillary. Meth-ods From January 2014 to October 2015, 200 cases of blood glucose detection in the center of the disease control depart-ment of our CDC were studied. According to their blood glucose levels, the patients were divided into low blood sugar group, normal group, abnormal glucose tolerance group and diabetic group. Blood glucose was detected by using the automatic bio-chemical analyzer to measure blood glucose of blood and blood glucose in the blood and blood of the finger tip, which were collected from 200 cases of the patients. Results There were no significant differences in blood glucose levels between the blood glucose test results of the blood glucose test of the blood glucose and the blood glucose in the blood glucose of the patients with low blood glucose, glucose tolerance and glucose tolerance test in the patients with low blood glucose and glu-cose tolerance. Conclusion The method of blood glucose detection in blood glucose of finger tip has a high accuracy, and it is close to that of venous blood glucose detection. It can effectively reflect the blood glucose level of the subjects, and can be used as an effective method for the monitoring and management of the community and family.%目的:对比分析指尖毛细血管全血血糖与静脉血浆血糖的检测结果,以探讨指尖毛细血管全血糖检测血糖的准确性。方法于2014年1月-2015年10月,选取在该疾控中心体检科进行血糖检测的200例受检者进行研究,按照其血糖情况进行分组,分为低血糖组、血糖正常组、糖耐量异常组、糖尿病组。分别于空腹状态时和餐后2 h,采集这200例受检者的指尖毛细血管全血和外周静脉血液,使用全自动生化分析仪进行血糖测定,对比指尖毛细血

  1. Polarization Sensitive Optical Coherence Tomography for Blood Glucose Monitoring in Human Subjects

    CERN Document Server

    Solanki, Jitendra; Sen, Pratima; Andrews, Joseph Thomas

    2012-01-01

    A device based on Polarization sensitive optical coherence tomography is developed to monitor blood glucose levels in human subjects. The device was initially tested with tissue phantom. The measurements with human subjects for various glucose concentration levels are found to be linearly dependent on the degree of circular polarization obtainable from the PS-OCT.

  2. Kinetic Parameters for the Noncatalyzed and Enzyme-Catalyzed Mutarotation of Glucose Using a Blood Glucometer

    Science.gov (United States)

    Hardee, John R.; Delgado, Bryan; Jones, Wray

    2011-01-01

    The kinetic parameters for the conversion of alpha-D-glucose to beta-D-glucose were measured using a blood glucometer. The reaction order, rate constant, and Arrhenius activation energy are reported for the noncatalyzed reaction and turnover number and Michaelis constant are reported for the reaction catalyzed by porcine kidney mutarotase. The…

  3. Modelling, verification, and calibration of a photoacoustics based continuous non-invasive blood glucose monitoring system

    Science.gov (United States)

    Pai, Praful P.; Sanki, Pradyut K.; Sarangi, Satyabrata; Banerjee, Swapna

    2015-06-01

    This paper examines the use of photoacoustic spectroscopy (PAS) at an excitation wavelength of 905 nm for making continuous non-invasive blood glucose measurements. The theoretical background of the measurement technique is verified through simulation. An apparatus is fabricated for performing photoacoustic measurements in vitro on glucose solutions and in vivo on human subjects. The amplitude of the photoacoustic signals measured from glucose solutions is observed to increase with the solution concentration, while photoacoustic amplitude obtained from in vivo measurements follows the blood glucose concentration of the subjects, indicating a direct proportionality between the two quantities. A linear calibration method is applied separately on measurements obtained from each individual in order to estimate the blood glucose concentration. The estimated glucose values are compared to reference glucose concentrations measured using a standard glucose meter. A plot of 196 measurement pairs taken over 30 normal subjects on a Clarke error grid gives a point distribution of 82.65% and 17.35% over zones A and B of the grid with a mean absolute relative deviation (MARD) of 11.78% and a mean absolute difference (MAD) of 15.27 mg/dl (0.85 mmol/l). The results obtained are better than or comparable to those obtained using photoacoustic spectroscopy based methods or other non-invasive measurement techniques available. The accuracy levels obtained are also comparable to commercially available continuous glucose monitoring systems.

  4. One session treatment for pediatric blood-injection-injury phobia: A controlled multiple baseline trial.

    Science.gov (United States)

    Oar, Ella L; Farrell, Lara J; Waters, Allison M; Conlon, Elizabeth G; Ollendick, Thomas H

    2015-10-01

    The present study evaluated the effectiveness of a modified One Session Treatment (OST), which included an e-therapy homework maintenance program over 4 weeks for Blood-Injection-Injury (BII) phobia in children and adolescents. Using a single case, non-concurrent multiple-baseline design, 24 children and adolescents (8-18 years; 7 males, 17 females) with a primary diagnosis of BII phobia were randomly assigned to a one, two or three week baseline prior to receiving OST. Primary outcome measures included diagnostic severity, diagnostic status, and child and parent fear ratings. Secondary outcome measures included avoidance during behavioural avoidance tasks (BAT), global functioning and self and parent reported anxiety, fear and depression. Efficacy was assessed at post-treatment, 1-month, and 3-month follow-up. BII symptoms and diagnostic severity remained relatively stable during the baseline periods and then significantly improved following implementation of the intervention. Treatment response was supported by changes across multiple measures, including child, parent and independent clinician ratings. At post-treatment 8 of the 24 (33.33%) children were BII diagnosis free. Treatment gains improved at follow-ups with 14 (58.33%) children diagnosis free at 1-month follow-up and 15 (62.5%) diagnosis free at 3-month follow-up. Preliminary findings support the effectiveness of a modified OST approach for BII phobic youth with treatment outcomes improving over follow-up intervals. PMID:26313620

  5. Base-line O2 extraction influences cerebral blood flow response to hematocrit

    International Nuclear Information System (INIS)

    The authors have shown that the fall in cerebral blood flow (CBF) as hematocrit (Hct) rises is due to the independent effects of increasing red blood cell (RBC) concentration and arterial O2 content (CaO2). In the present study, they tested the hypothesis that the magnitude of the effect of RBC concentration depends on the base-line cerebral fractional oxygen extraction (E). Pentobarbital-anesthetized 1- to 7-day-old sheep were first exchange transfused with plasma to lower Hct to 20%. Base-line E was set to either high or low levels by induction of hypocarbia, or hypercarbia. A second isovolemic exchange transfusion with pure methemoglobin-containing adult sheep red cells then raised Hct with no significant increase in CaO2. PaCO2 was maintained and other variables with potential effect on CBF did not change. CBF corrected for any individual alteration in CMRo2. This study supports the hypothesis that the magnitude of the decline in CBF secondary to an increase in RBC concentration depends on the initial E. The effect of RBC concentration on CBF is greatest when E is low

  6. Optical coherence tomography for glucose monitoring in blood

    Science.gov (United States)

    Ullah, Hafeez; Hussain, Fayyaz; Ikram, Masroor

    2015-08-01

    In this review, we have discussed the potential application of the emerging imaging modality, i.e., optical coherence tomography (OCT) for glucose monitoring in biological tissues. OCT provides monitoring of glucose diffusion in different fibrous tissues like in sclera by determining the permeability rate with acceptable accuracy both in type 1 and in type 2 diabetes. The maximum precision of glucose measurement in Intralipid suspensions, for example, with the OCT technique yields the accuracy up to 4.4 mM for 10 % Intralipid and 2.2 mM for 3 % Intralipid.

  7. Diabetes and puberty : studies on hormonal factors of importance to the blood glucose control

    OpenAIRE

    Zachrisson, Ingmar

    2000-01-01

    It is well known that, in children with type 1 diabetes, metabolic control often deteriorates during puberty. Better understanding of the mechanisms that cause deterioration of blood glucose control can lead to improved therapeutic approaches. Preliminary observations suggest that one component of the impaired glycemic control is a large variation in blood glucose. Several of the hormonal changes during puberty affect insulin sensitivity and could, in addition to lifestyle f...

  8. How to compare adequacy of algorithms to control blood glucose in the intensive care unit?

    OpenAIRE

    Van den Berghe , Greet

    2004-01-01

    Vogelzang et al. retrospectively assessed a derivative marker of blood glucose control over time in the intensive care unit (ICU), "the hyperglycemic index" (HGI), in relation to outcome. The HGI predicted mortality better than other indices of blood glucose control that do not take the duration of hyperglycemia into account. This provided further support to the concept of maintaining normoglycemia with insulin throughout intensive care in order to improve outcome. The HGI was also proposed a...

  9. Clinical implication of blood glucose monitoring in general dental offices: the Ehime Dental Diabetes Study

    OpenAIRE

    Harase, Tadahiro; Nishida, Wataru; Hamakawa, Tomohiro; Hino, Satoshi; Shigematsu, Kenji; Kobayashi, Satoru; Sako, Hirofumi; Ito, Shirou; Murakami, Hajime; Nishida, Kei; Inoue, Hiroshi; Fujisawa, Masahito; Yoshizu, Hiroshi; Kawamura, Ryoichi; Takata, Yasunori

    2015-01-01

    Objective We examined whether general dentists can contribute to the detection of patients with undiagnosed diabetes and prediabetes by monitoring blood glucose in dental clinics. Research design and methods A total of 716 patients who visited clinics for dental treatment were enrolled and classified into 3 groups (mild, moderate, and severe) according to Kornman's criteria for periodontitis. The correlations between the casual blood glucose level, presence or absence of the history of diabet...

  10. Effect of Collaborative Care System (CCS) on Blood Glucose Levels in Type 2 Diabetes Mellitus Outpatient

    OpenAIRE

    Nuryati Kuman; Bangunawati Rahajeng

    2016-01-01

    Some health system in various countries in the world is highly fragmented and is unable to resolve health problems. With collaborative care system, it is expected that DM patients can be managed well. We conducted a study to determine the effect of collaborative care system on blood glucose levels of patients with type 2 diabetes mellitus. This study uses a quasi-experimental design. Data was obtained by measuring random blood glucose levels in patients with type 2 diabetes mellitus. The samp...

  11. Scale Space Methods for Analysis of Type 2 Diabetes Patients' Blood Glucose Values

    OpenAIRE

    Stein Olav Skrøvseth; Fred Godtliebsen

    2011-01-01

    We describe how scale space methods can be used for quantitative analysis of blood glucose concentrations from type 2 diabetes patients. Blood glucose values were recorded voluntarily by the patients over one full year as part of a self-management process, where the time and frequency of the recordings are decided by the patients. This makes a unique dataset in its extent, though with a large variation in reliability of the recordings. Scale space and frequency space techniques are suited to ...

  12. Blood Glucose Alterations in Spinal versus General anesthesia in those undergoing Cesarean Section Delivery

    OpenAIRE

    Alireza Manafi; Habibollah Zakeri; Fatemeh Salahyan; Marzieh Tavassoli; Fahimeh Shekoohi; Roya Kokabi; Sahar Khazforoosh

    2015-01-01

    Introduction: Major body injury or surgery is associated with reproducible metabolic and hormonal responses. Alteration of blood glucose levels is one of the necessary metabolic changes to surgical stress. Surgical techniques and different methods of anesthesia are factors that can help to control and balance the body’s hormones. One of the most effective ways for decline the endocrine-metabolic response is local anesthesia. We conducted this study to compare the measurement of blood glucose ...

  13. System Accuracy Evaluation of the GlucoRx Nexus Voice TD-4280 Blood Glucose Monitoring System

    OpenAIRE

    Muhammad Khan; Keith Broadbent; Mike Morris; David Ewins; Franklin Joseph

    2014-01-01

    Use of blood glucose (BG) meters in the self-monitoring of blood glucose (SMBG) significantly lowers the risk of diabetic complications. With several BG meters now commercially available, the International Organization for Standardization (ISO) ensures that each BG meter conforms to a set degree of accuracy. Although adherence to ISO guidelines is a prerequisite for commercialization in Europe, several BG meters claim to meet the ISO guidelines yet fail to do so on internal validation. We con...

  14. Effect of Sulfonylureas Administered Centrally on the Blood Glucose Level in Immobilization Stress Model

    OpenAIRE

    Sharma, Naveen; Sim, Yun-Beom; Park, Soo-hyun; Lim, Su-Min; Kim, Sung-Su; Jung, Jun-Sub; Hong, Jae-Seung; Suh, Hong-Won

    2015-01-01

    Sulfonylureas are widely used as an antidiabetic drug. In the present study, the effects of sulfonylurea administered supraspinally on immobilization stress-induced blood glucose level were studied in ICR mice. Mice were once enforced into immobilization stress for 30 min and returned to the cage. The blood glucose level was measured 30, 60, and 120 min after immobilization stress initiation. We found that intracerebroventricular (i.c.v.) injection with 30 µg of glyburide, glipizide, glimepir...

  15. Improvements on Noninvasive Blood Glucose Biosensors Using Wavelets for Quick Fault Detection

    OpenAIRE

    Germán Campetelli; David Zumoffen; Marta Basualdo

    2011-01-01

    Noninvasive blood glucose sensors are still under development stage considering that they are far from being suitable for use in anartificial pancreas. The latter has three main parts: the blood glucose sensor, the insulin pump and the controller. However, for the biosensor analyzed here, some common failures such as signal shifts and unreal picks were found. They must be taken into account, for computing the correct insulin dosage for diabetic persons. Hence, a fault det...

  16. Self-monitoring of blood glucose improved glycaemic control and 10-year coronary heart disease risk profile of type 2 diabetic patients

    Institute of Scientific and Technical Information of China (English)

    Ezenwaka Chidum; JonesLeCointe Altheia; Dimgba Agbai; Okali Fidelis; Skinner Teppany; Rodriguez Martina; Extavour Rian; Davis Verdine; Spencer Alida; Mayers Hasina

    2011-01-01

    Background The debate over the overall benefits of self-monitoring of blood glucose in type 2 diabetes patients is still continuing.We aimed to assess the difference in glycaemic control and coronary heart disease (CHD) risk levels of experimental type 2 diabetes patients provided with facilities for self-monitoring blood glucose and their counterparts without such facilities.Methods Sixty-one patients who had no prior experience in using glucometers were studied as intervention (n=30) and control (n=31) groups.The intervention group was trained in self-monitoring of blood glucose and documentation.Baseline blood glucose and fasting blood glucose were measured and the intervention patients were provided with glucometers and advised to self-monitor their fasting and postprandial blood glucose over six months.The 10-year CHD risk levels were determined with the United Kingdom Prospective Diabetes Study-derived risk engine calculator.Results The age and diabetes duration were similar in the two groups (P >0.05).The majority of the patients were unemployed or retired females with only a primary level education.After 3 months,the haemogolbin A1c (HbA1c) levels of the control patients remained unchanged ((7.8±0.3)% vs.(7.9±0.4)%,P >0.05) whereas the HbA1c levels of the intervention patients were significantly reduced from the baseline at three ((9.6±0.3)% vs.(7.8±0.3)%,P <0.001) and six ((9.2±0.4)% vs.(7.5±0.3)%,P <0.001) months.Interestingly,while the 10-year CHD risk level of the control group remained unchanged after three months,that of the intervention group was remarkably reduced at three and six months from the baseline level ((7.4±1.3)% vs.(4.5±0.9)%,P=0.056).Conclusion Self-monitoring of blood glucose in type 2 diabetes patients significantly improved glycaemic control and the CHD risk profile,suggesting that type 2 diabetes patients will potentially benefit from inclusion of glucose meters and testing strips in their health-care package.

  17. The rate-limiting step for glucose transport into the hypothalamus is across the blood-hypothalamus interface

    OpenAIRE

    Poitry-Yamate, Carole; Lei, Hongxia; Gruetter, Rolf

    2009-01-01

    Specialized glucosensing neurons are present in the hypothalamus, some of which neighbor the median eminence, where the blood-brain barrier has been reported leaky. A leaky blood-brain barrier implies high tissue glucose levels and obviates a role for endothelial glucose transporters in the control of hypothalamic glucose concentration, important in understanding the mechanisms of glucose sensing We therefore addressed the question of blood-brain barrier integrity at the hypothalamus for gluc...

  18. Insoluble Fiber in Young Barley Leaf Suppresses the Increment of Postprandial Blood Glucose Level by Increasing the Digesta Viscosity

    Directory of Open Access Journals (Sweden)

    Akira Takano

    2013-01-01

    Full Text Available Barley (Hordeum vulgare L. is a well-known cereal plant. Young barley leaf is consumed as a popular green-colored drink, which is named “Aojiru” in Japan. We examined the effects of barley leaf powder (BLP and insoluble fibers derived from BLP on postprandial blood glucose in rats and healthy Japanese volunteers. BLP and insoluble fibers derived from BLP suppressed the increment of postprandial blood glucose levels in rats (, and increased the viscosity of their digesta. The insoluble fibers present in BLP might play a role in controlling blood glucose level by increasing digesta viscosity. In human, BLP suppressed the increment of postprandial blood glucose level only in those which exhibited higher blood glucose levels after meals (. BLP might suppress the increment of postprandial blood glucose level by increasing digesta viscosity in both of rats and humans who require blood glucose monitoring.

  19. THE EFFECT OF AVOCADO (PERSEA AMERICANA MILL. LEAVES EXTRACT TOWARDS THE MOUSE'S BLOOD GLUCOSE DECREASE WITH THE GLUCOSE TOLERANCE METHOD

    Directory of Open Access Journals (Sweden)

    Shirly Kumala*, Hesty Utami and Wahyu Kartika Sari

    2013-02-01

    Full Text Available Decrease in blood glucose level test with the use of oral glucose tolerance method from Avocado leaves was carried out. Swiss Webster male mice were divided randomly into five groups. They were negative control, positive control (Glipizide 0.013 mg/20 g BW and three test groups treated with dosage of avocado leaves ethanol extract 0.490 g/kg, 0.980 g/kg and 1.960 g /BW respectively. Experiment was begun with feeding the mice with the test solution followed by feeding glucose solution (1.5 g/kg BW 30 minutes later. Blood glucose levels were assessed using glucometer kit, from zero to 3 hours, at ½ hourly interval. These results analysed by one way ANOVA showed there were significant difference (p<0.05 between Ethanol extract of avocado leaves treated with mice (0.490, 0.980 g/kg BW and control groups. Furthermore, when Tukey’s test was performed, avocado treated mice (1.960g/kg BW reduce glucose level to 64.27%. The effectiveness of this treatment was not significantly different to those treated with glipizide (68.50%.

  20. Blood glucose regulation mechanism in depressive disorder animal model during hyperglycemic states.

    Science.gov (United States)

    Lim, Su-Min; Park, Soo-Hyun; Sharma, Naveen; Kim, Sung-Su; Lee, Jae-Ryeong; Jung, Jun-Sub; Suh, Hong-Won

    2016-06-01

    Depression is more common among diabetes people than in the general population. In the present study, blood glucose change in depression animal model was characterized by various types of hyperglycemia models such as d-glucose-fed-, immobilization stress-, and drug-induced hyperglycemia models. First, the ICR mice were enforced into chronic restraint stress for 2h daily for 2 weeks to produce depression animal model. The animals were fed with d-glucose (2g/kg), forced into restraint stress for 30min, or administered with clonidine (5μg/5μl) supraspinally or spinally to produce hyperglycemia. The blood glucose level in depression group was down-regulated compared to that observed in the normal group in d-glucose-fed-, restraint stress-, and clonidine-induced hyperglycemia models. The up-regulated corticosterone level induced by d-glucose feeding or restraint stress was reduced in the depression group while the up-regulation of plasma corticosterone level is further elevated after i.t. or i.c.v. clonidine administration in the depression group. The up-regulated insulin level induced by d-glucose feeding or restraint stress was reduced in the depression group. On the other hand, blood corticosterone level in depression group was up-regulated compared to the normal group after i.t. or i.c.v. clonidine administration. Whereas the insulin level in depression group was not altered when mice were administered clonidine i.t. or i.c.v. Our results suggest that the blood glucose level in depression group is down-regulated compared to the normal group during d-glucose-fed-, immobilization stress-, and clonidine-induced hyperglycemia in mice. The down-regulation of the blood glucose level might be one of the important pathophysiologic changes in depression. PMID:27034116

  1. Diurnal variation in baseline human regional cerebral blood flow demonstrated by PET

    Energy Technology Data Exchange (ETDEWEB)

    Diehl, D.J.; Mintun, M.A.; Moore, R.Y. [Univ. of Pittsburgh, PA (United States)] [and others

    1994-05-01

    We have previously described the diurnal variation in regional cerebral blood flow (rCBF) response to bright light in human subjects as demonstrated by the positron emission tomography (PET) activation method. In this abstract, we report the differences in rCBF (an indicator of differences in regional neuronal activity) between the evening and midday dim light baseline scans which served as the control states in the above bright light activation study. Five right-handed, healthy volunteers underwent both an evening (8pm) and a midday (12N) O-15 water PET scanning session. Each scanning session was preceded by one hour of dim light adaptation (50 lux) and consisted of six rCBF scans at three different light intensities in an AABBCC sequence (A=50 lux, B=2500 lux, C=7000lux). Significant differences in rCBF between the evening and midday 50 lux states were identified using the statistical parametric mapping method developed by Friston et al (p<.001). The evening scans demonstrated areas of greater relative blood flow in the pineal gland, the lateral temporal cortex bilaterally, the right lateral prefrontal cortex, the superior aspect of the anterior cingulate, and the left thalamus. The midday scans showed areas of greater relative blood flow in the visual cortex, the left lateral prefrontal cortex. the inferior aspect of the anterior cingulate, the left parietal cortex and the cerebellum. Our results demonstrate an extensive diurnal variation in baseline human rCBF. This indicates that time of day may be an important variable in conducting and interpreting functional brain imaging studies. Furthermore, these results suggest possible neuroanatomical substrates through which the circadian system may regulate the various physiologic and behavioral processes that manifest circadian rhythms.

  2. Alanine aminotransferase is associated with an adverse nocturnal blood glucose profile in individuals with normal glucose regulation.

    Directory of Open Access Journals (Sweden)

    Jian Zhou

    Full Text Available OBJECTIVE: Although the association between alanine aminotransferase (ALT levels and risk of type 2 diabetes is well-studied, the effects of slightly increased ALT levels within the normal range on the temporal normal glucose profile remains poorly understood. METHODS: A total of 322 Chinese subjects without impaired glucose tolerance or previous diagnoses of diabetes were recruited for study from 10 hospitals in urban areas across China. All subjects wore a continuous glucose monitoring (CGM system for three consecutive days. The diurnal (06∶00-20∶00 and nocturnal (20∶00-06∶00 mean blood glucose (MBG levels were calculated. Subjects were stratified by ALT quartile level and correlation analyses were performed. RESULTS: The median ALT level was 17 IU/L, and subjects with ALT ≥17 IU/L had higher nocturnal MBG level than those with ALT 0.05. Multivariate stepwise regression analysis of elevated nocturnal MBG identified increased HOMA-IR, elevated ALT levels, and decreased homeostatic model assessment of ß-cell function as independent factors (all, P<0.05. CONCLUSIONS: Mildly elevated ALT levels, within the normal range, are associated with unfavorable nocturnal glucose profiles in Chinese subjects with normal glucose regulation.

  3. Alanine Aminotransferase Is Associated with an Adverse Nocturnal Blood Glucose Profile in Individuals with Normal Glucose Regulation

    Science.gov (United States)

    Li, Hong; Ran, Xingwu; Yang, Wenying; Li, Qiang; Peng, Yongde; Li, Yanbing; Gao, Xin; Luan, Xiaojun; Wang, Weiqing; Jia, Weiping

    2013-01-01

    Objective Although the association between alanine aminotransferase (ALT) levels and risk of type 2 diabetes is well-studied, the effects of slightly increased ALT levels within the normal range on the temporal normal glucose profile remains poorly understood. Methods A total of 322 Chinese subjects without impaired glucose tolerance or previous diagnoses of diabetes were recruited for study from 10 hospitals in urban areas across China. All subjects wore a continuous glucose monitoring (CGM) system for three consecutive days. The diurnal (06∶00–20∶00) and nocturnal (20∶00–06∶00) mean blood glucose (MBG) levels were calculated. Subjects were stratified by ALT quartile level and correlation analyses were performed. Results The median ALT level was 17 IU/L, and subjects with ALT ≥17 IU/L had higher nocturnal MBG level than those with ALT 0.05). Multivariate stepwise regression analysis of elevated nocturnal MBG identified increased HOMA-IR, elevated ALT levels, and decreased homeostatic model assessment of ß-cell function as independent factors (all, P<0.05). Conclusions Mildly elevated ALT levels, within the normal range, are associated with unfavorable nocturnal glucose profiles in Chinese subjects with normal glucose regulation. PMID:23424646

  4. A vitamin, mineral, herb dietary supplement effect on blood glucose in uncontrolled type II diabetic subjects.

    Science.gov (United States)

    González, Michael J; Ricart, Carlos M; Miranda-Massari, Jorge

    2004-06-01

    We tested a dietary supplement formulated with a synergistic combination of vitamins, minerals, herbals in a group of 15 patients with uncontrolled diabetes type II. The supplement was given for 30 days. Fasting blood glucose was measured prior to the supplementation and at the end of the 30 days treatment period. Blood glucose was significantly reduced in all patients with no adverse effects. This orthomolecular correction of faulty glucose metabolism with a combination of nontoxic, safe and fairly inexpensive nutraceuticals needs to be further substantiated. Nervertheless the idea of correcting metabolism with micronutrients is a new concept of genetic nutritioneering that seems appealing and cost effective. PMID:15377060

  5. Using meta-differential evolution to enhance a calculation of a continuous blood glucose level.

    Science.gov (United States)

    Koutny, Tomas

    2016-09-01

    We developed a new model of glucose dynamics. The model calculates blood glucose level as a function of transcapillary glucose transport. In previous studies, we validated the model with animal experiments. We used analytical method to determine model parameters. In this study, we validate the model with subjects with type 1 diabetes. In addition, we combine the analytic method with meta-differential evolution. To validate the model with human patients, we obtained a data set of type 1 diabetes study that was coordinated by Jaeb Center for Health Research. We calculated a continuous blood glucose level from continuously measured interstitial fluid glucose level. We used 6 different scenarios to ensure robust validation of the calculation. Over 96% of calculated blood glucose levels fit A+B zones of the Clarke Error Grid. No data set required any correction of model parameters during the time course of measuring. We successfully verified the possibility of calculating a continuous blood glucose level of subjects with type 1 diabetes. This study signals a successful transition of our research from an animal experiment to a human patient. Researchers can test our model with their data on-line at https://diabetes.zcu.cz. PMID:27393799

  6. Energized by love: thinking about romantic relationships increases positive affect and blood glucose levels.

    Science.gov (United States)

    Stanton, Sarah C E; Campbell, Lorne; Loving, Timothy J

    2014-10-01

    We assessed the impact of thinking of a current romantic partner on acute blood glucose responses and positive affect over a short period of time. Participants in romantic relationships were randomly assigned to reflect on their partner, an opposite-sex friend, or their morning routine. Blood glucose levels were assessed prior to reflection, as well as at 10 and 25 min postreflection. Results revealed that individuals in the routine and friend conditions exhibited a decline in glucose over time, whereas individuals in the partner condition did not exhibit this decline (rather, a slight increase) in glucose over time. Reported positive affect following reflection was positively associated with increases in glucose, but only for individuals who reflected on their partner, suggesting this physiological response reflects eustress. These findings add to the literature on eustress in relationships and have implications for relationship processes. PMID:24924647

  7. Control of Blood Glucose for People with Type 1 Diabetes: an in Vivo Study

    DEFF Research Database (Denmark)

    Boiroux, Dimitri; Schmidt, Signe; Duun-Henriksen, Anne Katrine;

    2012-01-01

    Since continuous glucose monitoring (CGM) technology and insulin pumps have improved recent years, a strong interest in a closed-loop articial pancreas for people with type 1 diabetes has arisen. Presently, a fully automated controller of blood glucose must face many challenges, such as daily...... variations of patient's physiology and lack of accuracy of glucose sensors. In this paper we design and discuss an algorithm for overnight closed-loop control of blood glucose in people with type 1 diabetes. The algorithm is based on Model Predictive Control (MPC). We use an oset-free autoregressive model...... with exogenous input and moving average (ARMAX) to model the patient. Observer design and a time-varying glucose reference signal improve robustness of the algorithm. We test the algorithm in two clinical studies conducted at Hvidovre Hospital. The rst study took place overnight, and the second one...

  8. Association between whole blood mercury and glucose intolerance among adult Inuit in Greenland

    DEFF Research Database (Denmark)

    Jeppesen, Charlotte; Valera, Beatriz; Nielsen, Nina O; Bjerregaard, Peter; Jørgensen, Marit E

    OBJECTIVES: The Arctic diet is partly constituted by traditional food characterized by top predator animals such as whales, walrus, and seals with high mercury content. Mercury exposure has been associated with glucose intolerance in Western populations. We studied the association between whole...... blood mercury and glucose intolerance in a highly exposed non-Western population METHODS: Cross-sectional study of 2640 Inuit (18+ years) with information on ancestry, smoking, waist circumference, total energy intake, and physical activity. Mercury, fasting- and 2-h plasma glucose, insulin, and c......-peptide were measured in blood. Fasting participants without diabetes were classified into normal glucose tolerance, impaired glucose tolerance, impaired fasting glycemia, or type 2 diabetes. We calculated hepatic insulin resistance with homoeostatic model assessment - insulin resistance index, peripheral...

  9. Photoacoustic blood glucose and skin measurement based on optical scattering effect

    Science.gov (United States)

    Zhao, Zuomin; Myllyla, Risto A.

    2002-07-01

    Non-invasive blood glucose determination has been investigated by more than 100 research groups in the world during the past fifteen years. The commonly optical methods are based on the capacity of near-IR light to penetrate a few hundreds micrometers or a few millimeters into human tissue where it interacts with glucose. A change of glucose concentration may modify the optical parameters in tissue, with the result that its glucose concentration can be extracted by analyzing the received optical signals. This paper demonstrates that glucose affects on the scattering coefficient of human blood, by applying the streak camera and pulsed photoacoustic techniques; and drinking water seems also affecting on PA signal from skin surface.

  10. Development of portable health monitoring system for automatic self-blood glucose measurement

    Science.gov (United States)

    Kim, Huijun; Mizuno, Yoshihumi; Nakamachi, Eiji; Morita, Yusuke

    2010-02-01

    In this study, a new HMS (Health Monitoring System) device is developed for diabetic patient. This device mainly consists of I) 3D blood vessel searching unit and II) automatic blood glucose measurement (ABGM) unit. This device has features such as 1)3D blood vessel location search 2) laptop type, 3) puncturing a blood vessel by using a minimally invasive micro-needle, 4) very little blood sampling (10μl), and 5) automatic blood extraction and blood glucose measurement. In this study, ABGM unit is described in detail. It employs a syringe type's blood extraction mechanism because of its high accuracy. And it consists of the syringe component and the driving component. The syringe component consists of a syringe itself, a piston, a magnet, a ratchet and a micro-needle whose inner diameter is about 80μm. And the syringe component is disposable. The driving component consists of body parts, a linear stepping motor, a glucose enzyme sensor and a slider for accurate positioning control. The driving component has the all-in-one mechanism with a glucose enzyme sensor for compact size and stable blood transfer. On designing, required thrust force to drive the slider is designed to be greater than the value of the blood extraction force. Further, only one linear stepping motor is employed for blood extraction and transportation processes. The experimental result showed more than 80% of volume ratio under the piston speed 2.4mm/s. Further, the blood glucose was measured successfully by using the prototype unit. Finally, the availability of our ABGM unit was confirmed.

  11. Stochastic and Optimization Programming for Blood Glucose & Insulin Regulatory Systems of Type-2 Diabetes

    Directory of Open Access Journals (Sweden)

    P. Tirupathi Rao

    2012-11-01

    Full Text Available In this paper a stochastic modeling and optimization problem is developed for blood glucose and insulin regulatory system suitable for management of type-2 diabetes patients. The rates of arrival and consumption of glucose and insulin in the blood are assumed as Poisson parameters and developed a model through stochastic processes. A stochastic programming problem for maintaining the optimized glucose and insulin levels of the blood is developed. An objective function for maximizing the energy release subject to the constraints on the consumption of glucose is formulated. Sensitivity analysis was carried out and observed the model behaviour through influencing parameters. Enhancing the developed programming problem as desk top automation system will make this work more accessible to the decision makers of Health care industry.

  12. Evaluation of two methods of rapid blood-glucose monitoring by unskilled personnel during surgery

    DEFF Research Database (Denmark)

    Madsbad, S; Adelhøj, B; Bigler, Dennis Richard;

    1984-01-01

    % of the readings below laboratory values -20%. All situations with severe hypoglycaemia were detected with both strips. The study also demonstrates the ineffectiveness of s.c. insulin regimens during surgery. Only 47% of the measured blood glucose values were within the range of 5.5-10 mmol/l and two......The accuracy of two rapid methods of blood-glucose monitoring without (Haemo-glucotest 1-44) and with a reflectance meter (Hypocount B) was compared using a laboratory method. The assessment was carried out by personnel with no previous experience in measuring blood glucose. Eighty-five percent of...... the 92 measurements obtained with the hypocount B were within +/- 20% of the laboratory glucose values. Using haemo-glucotest 1-44 strips, 74% of the readings were within +/- 20% of the reference laboratory values. For values below 5.5 mmol/l, there was a tendency for results to be too low, with 77...

  13. Measurement of tissue optical properties with optical coherence tomography: Implication for noninvasive blood glucose concentration monitoring

    Science.gov (United States)

    Larin, Kirill V.

    Approximately 14 million people in the USA and more than 140 million people worldwide suffer from diabetes mellitus. The current glucose sensing technique involves a finger puncture several times a day to obtain a droplet of blood for analysis. There have been enormous efforts by many scientific groups and companies to quantify glucose concentration noninvasively using different optical techniques. However, these techniques face limitations associated with low sensitivity, accuracy, and insufficient specificity of glucose concentrations over a physiological range. Optical coherence tomography (OCT), a new technology, is being applied for noninvasive imaging in tissues with high resolution. OCT utilizes sensitive detection of photons coherently scattered from tissue. The high resolution of this technique allows for exceptionally accurate measurement of tissue scattering from a specific layer of skin compared with other optical techniques and, therefore, may provide noninvasive and continuous monitoring of blood glucose concentration with high accuracy. In this dissertation work I experimentally and theoretically investigate feasibility of noninvasive, real-time, sensitive, and specific monitoring of blood glucose concentration using an OCT-based biosensor. The studies were performed in scattering media with stable optical properties (aqueous suspensions of polystyrene microspheres and milk), animals (New Zealand white rabbits and Yucatan micropigs), and normal subjects (during oral glucose tolerance tests). The results of these studies demonstrated: (1) capability of the OCT technique to detect changes in scattering coefficient with the accuracy of about 1.5%; (2) a sharp and linear decrease of the OCT signal slope in the dermis with the increase of blood glucose concentration; (3) the change in the OCT signal slope measured during bolus glucose injection experiments (characterized by a sharp increase of blood glucose concentration) is higher than that measured in

  14. Continuous monitoring of blood glucose in the practice of endocrinologist

    Directory of Open Access Journals (Sweden)

    Yu I Philippov

    2012-12-01

    Full Text Available Continuous glucose monitoring - an important diagnostic, teaching and treatment tool for patients with diabetes mellitus, which is increasingly becoming a part of routine clinical practice in endocrinology. This article presents an overview of modern techniques, their advantages and disadvantages, evidence basis and place in everyday clinical practice. The article discusses the key factors affecting the efficiency, indications, contraindications, conditions of use of the continuous glucose monitoring systems in patients with diabetes mellitus, gives an algorithm for the application of this technique in clinical practice.

  15. Self-Blood Glucose Monitoring in Diabetes Mellitus (Beyond the Basics)

    Science.gov (United States)

    ... Use ©2016 UpToDate, Inc. Patient education: Self-blood glucose monitoring in diabetes mellitus (Beyond the Basics) Author ... 2016. | This topic last updated: Oct 19, 2015. BLOOD SUGAR TESTING OVERVIEW — If you have diabetes, you have ...

  16. Quality assessment of patients’ self-monitoring of blood glucose in community pharmacies

    Directory of Open Access Journals (Sweden)

    Kjome RL

    2010-03-01

    Full Text Available Objective: To evaluate diabetes patients’ self-monitoring of blood glucose using a community pharmacy-based quality assurance procedure, to investigate whether the procedure improved the quality of the patient performance of self monitoring of blood glucose, and to examine the opinions of the patients taking part in the study. Methods: The results of patient blood glucose measurements were compared to the results obtained with HemoCue Glucose 201+ by pharmacy employees in 16 Norwegian community pharmacies. Patient performance was monitored using an eight item checklist. Patients whose blood glucose measurements differed from pharmacy measurements by more than 20% were instructed in the correct use of their glucometer. The patients then re-measured their blood glucose. If the results were still outside the set limits, the control procedure was repeated with a new lot of glucometer strips, and then with a new glucometer. The patients returned for a follow-up visit after three months. Results: During the first visit, 5% of the 338 patients had measurements that deviated from pharmacy blood glucose values by more than 20% and user errors were observed for 50% of the patients. At the second visit, there was no significant change in the analytical quality of patient measurements, but the percentage of patients who made user errors had decreased to 29% (p < 0.001. Eighty-five percent of the patients reported that they used their blood glucose results to adjust medication, exercise or meals. Fifty-one percent of the patients reported a greater trust in their measurements after the second visit. Eighty percent of patients wished to have their measurements assessed yearly. Of these patients, 83% preferred to have the assessment done at the community pharmacy. Conclusion: A community pharmacy-based quality assessment procedure of patients’ self monitoring of blood glucose significantly reduced the number of user errors. The analytical quality of the

  17. Correlation of salivary glucose, blood glucose and oral candidal carriage in the saliva of type 2 diabetics: A case-control study

    OpenAIRE

    Satish Kumar; Padmashree, S.; Rema Jayalekshmi

    2014-01-01

    Objectives: To study the correlation between blood glucose levels and salivary glucose levels in type 2 diabetic patients, to study the relationship between salivary glucose levels and oral candidal carriage in type 2 diabetic patients and to determine whether salivary glucose levels could be used as a noninvasive tool for the measurement of glycemic control in type 2 diabetics. Study Design: The study population consisted of three groups: Group 1 consisted of 30 controlled diabetics and Grou...

  18. Tunable laser diode system for noninvasive blood glucose measurements.

    Science.gov (United States)

    Olesberg, Jonathon T; Arnold, Mark A; Mermelstein, Carmen; Schmitz, Johannes; Wagner, Joachim

    2005-12-01

    Optical sensing of glucose would allow more frequent monitoring and tighter glucose control for people with diabetes. The key to a successful optical noninvasive measurement of glucose is the collection of an optical spectrum with a very high signal-to-noise ratio in a spectral region with significant glucose absorption. Unfortunately, the optical throughput of skin is low due to absorption and scattering. To overcome these difficulties, we have developed a high-brightness tunable laser system for measurements in the 2.0-2.5 microm wavelength range. The system is based on a 2.3 microm wavelength, strained quantum-well laser diode incorporating GaInAsSb wells and AlGaAsSb barrier and cladding layers. Wavelength control is provided by coupling the laser diode to an external cavity that includes an acousto-optic tunable filter. Tuning ranges of greater than 110 nm have been obtained. Because the tunable filter has no moving parts, scans can be completed very quickly, typically in less than 10 ms. We describe the performance of the present laser system and avenues for extending the tuning range beyond 400 nm. PMID:16390586

  19. Study on optical measurement conditions for noninvasive blood glucose sensing

    Science.gov (United States)

    Xu, Kexin; Chen, Wenliang; Jiang, Jingying; Qiu, Qingjun

    2004-05-01

    Utilizing Near-infrared Spectroscopy for non-invasive glucose concentration sensing has been a focusing topic in biomedical optics applications. In this paper study on measuring conditions of spectroscopy on human body is carried out and a series of experiments on glucose concentration sensing are conducted. First, Monte Carlo method is applied to simulate and calculate photons" penetration depth within skin tissues at 1600 nm. The simulation results indicate that applying our designed optical probe, the detected photons can penetrate epidermis of the palm and meet the glucose sensing requirements within the dermis. Second, we analyze the influence of the measured position variations and the contact pressure between the optical fiber probe and the measured position on the measured spectrum during spectroscopic measurement of a human body. And, a measurement conditions reproduction system is introduced to enhance the measurement repeatability. Furthermore, through a series of transmittance experiments on glucose aqueous solutions sensing from simple to complex we found that though some absorption variation information of glucose can be obtained from measurements using NIR spectroscopy, while under the same measuring conditions and with the same modeling method, choices toward measured components reduce when complication degree of components increases, and this causes a decreased prediction accuracy. Finally, OGTT experiments were performed, and a PLS (Partial Least Square) mathematical model for a single experiment was built. We can easily get a prediction expressed as RMSEP (Root Mean Square Error of Prediction) with a value of 0.5-0.8mmol/dl. But the model"s extended application and reliability need more investigation.

  20. The associations of a marine diet with plasma lipids, blood glucose, blood pressure and obesity among the inuit in Greenland

    DEFF Research Database (Denmark)

    Bjerregaard, P; Pedersen, H S; Mulvad, G

    2000-01-01

    OBJECTIVE: To analyse the associations between the intake of fish and marine mammals and risk factors for cardiovascular disease, ie lipid profile, fasting blood glucose, blood pressure and obesity, in a population whose average consumption of n-3 fatty acids is high compared with Western countries...... statistically significant. The pattern was similar within groups with low, medium and high consumption of marine food. CONCLUSIONS: There are statistically significant associations between the consumption of marine food and certain lipid fractions in the blood also in this population with a very high average...... intake of marine food. The observation that blood glucose is positively associated with marine diet in a population survey is new and should be repeated. There was good agreement between the results for the reported consumption of seal and those for the biomarkers. SPONSORSHIP: The study was financially...

  1. The fluctuation of blood glucose, insulin and glucagon concentrations before and after insulin therapy in type 1 diabetes

    Science.gov (United States)

    Arif, Idam; Nasir, Zulfa

    2015-09-01

    A dynamical-systems model of plasma glucose, insulin and glucagon concentrations has been developed to investigate the effects of insulin therapy on blood glucose, insulin and glucagon regulations in type 1 diabetic patients. Simulation results show that the normal regulation of blood glucose concentration depends on insulin and glucagon concentrations. On type 1 diabetic case, the role of insulin on regulating blood glucose is not optimal because of the destruction of β cells in pancreas. These β cells destructions cause hyperglycemic episode affecting the whole body metabolism. To get over this, type 1 diabetic patients need insulin therapy to control the blood glucose level. This research has been done by using rapid acting insulin (lispro), long-acting insulin (glargine) and the combination between them to know the effects of insulin therapy on blood glucose, insulin and glucagon concentrations. Simulation results show that these different types of insulin have different effects on blood glucose concentration. Insulin therapy using lispro shows better blood glucose control after consumption of meals. Glargin gives better blood glucose control between meals and during sleep. Combination between lispro and glargine shows better glycemic control for whole day blood glucose level.

  2. A novel automated discontinuous venous blood monitoring system for ex vivo glucose determination in humans.

    Science.gov (United States)

    Schaller, R; Feichtner, F; Köhler, H; Bodenlenz, M; Plank, J; Wutte, A; Mader, J K; Ellmerer, M; Hellmich, R; Wedig, H; Hainisch, R; Pieber, T R; Schaupp, L

    2009-03-15

    Intensive insulin therapy reduces mortality and morbidity in critically ill patients but imposes great demands on medical staff who must take frequent blood samples for the determination of glucose levels. A solution to this resourcing problem would be provided by an automated blood monitoring system. The aim of the present clinical study was to evaluate such a system comprising an automatic blood sampling unit linked to a glucose biosensor. Our approach was to determine the correlation and system error of the sampling unit alone and of the combined system with respect to reference levels over 12h in humans. Two venous cannulae were inserted to connect the automatic and reference systems to the subjects. Blood samples were taken at 15 and 30 min intervals. The median Pearson coefficient of correlation between manually and automatically withdrawn blood samples was 0.982 for the sampling unit alone and 0.950 for the complete system. The biosensor had a linear range up to 20 mmoll(-1) and a 95% response time of Titration Error Grid analysis suggested an acceptable treatment in 99.56% of cases. Implementation of a "Keep Vein Open" saline infusion into the automated blood sampling system reduced blood withdrawal failures through occluded catheters fourfold. In summary, automated blood sampling from a peripheral vein coupled with automatic glucose determination is a promising alternative to frequent manual blood sampling. PMID:19135351

  3. Local cerebral blood flow and glucose metabolism during seizure in spontaneously epileptic El mice

    International Nuclear Information System (INIS)

    Local cerebral blood flow and glucose metabolism were examined in spontaneously epileptic El mice using autoradiography with 125I-IMP and 14C-DG in the interictal phase and during seizure. El (+) mice that developed generalized tonic-clonic convulsions and El (-) mice that received no stimulation and had no history of epileptic seizures were examined. The seizure non-susceptible, maternal strain ddY mice were used as control. Uptake ratios for IMP and DG in mouse brain were calculated using the autoradiographic density. In the interictal phase, the pattern of local cerebral blood flow of El (+) mice was similar to that of ddY and El (-) mice, and glucose metabolism in the hippocampus was higher in El (+) mice than in El (-) and ddY mice, but flow and metabolism were nearly matched. During seizure, no significant changed blood flow and increased glucose metabolism in the hippocampus, the epileptic focus, and no markedly changed blood flow and depressed glucose metabolism in other brain regions were observed and considered to be flow-metabolism uncoupling. These observations have never been reported in clinical or experimental studies of epilepsy. Seizures did not cause large regional differences in cerebral blood flow. Therefore, only glucose metabolism is useful for detection of the focus of secondary generalized seizures in El mice, and appeared possibly to be related to the pathophysiology of secondary generalized epilepsy in El mice. (author)

  4. Patient self-monitoring of blood glucose and refinements of conventional insulin treatment.

    Science.gov (United States)

    Tattersall, R; Gale, E

    1981-01-01

    The compelling evidence that blood glucose control will slow or prevent microvascular complications has stimulated research to find better ways of managing insulin-dependent diabetes. The excellent results obtained with "open loop" insulin infusion systems suggest that the relative failure of conventional treatment is the result of (1) a lack of appropriate feedback to the patient and (2) the use of insulin regimens which do not mimic physiologic insulinemia, particularly in the basal state. Doctors regard blood glucose measurements as an essential part of diabetic management and extension of this technology to patients has added a new dimension, particularly in the assessment of control. Nevertheless, home blood-glucose monitoring will not necessarily improve diabetic control; the best results have been obtained when it has been offered as part of a package deal which includes more investment of time and interest by patients and doctor together with joint discussions of problems and changes in treatment. The biggest problem with conventional twice daily insulin regimens is to sustain constant basal insulin levels during the night. Attempts to obtain fasting normoglycemia with an injection before supper often result in nocturnal hyperinsulinemia and hypoglycemia. This can usually be resolved by changing to a three times daily regimen with an extra injection of NPH insulin at bedtime. Three times daily insulin injections with feedback from home blood-glucose monitoring give as good blood glucose control as infusion systems and are cheaper and more acceptable to patients. PMID:7006390

  5. How Effective is Swedish Massage on Blood Glucose Level in Children with Diabetes Mellitus?

    Directory of Open Access Journals (Sweden)

    Firoozeh Sajedi

    2011-09-01

    Full Text Available "nThis study was conducted to determine the effect of Swedish massage on blood glucose level in children with diabetes mellitus (DM. It was prospective randomized controlled trial study that conducted on 36 children, 6-12 years old with DM, recruited from a hospital in Qom City, Iran. The children were randomly assigned to intervention and control groups. Swedish massage was performed 15 minutes, 3 times a week, for 3 months in intervention group. The blood glucose levels were evaluated immediately after every session of massage in two groups. The mean ages of children in the intervention (n=18 and control (n=18 groups were 9.05 ± 1.55 and 9.83 ±2.03 years respectively. There was statistically no significant difference in blood glucose levels before intervention between two groups (P=0.586, but the blood glucose levels were lower significantly in intervention group in comparison with control group after intervention (P<0.0001. Addition of Swedish massage to daily routines; exercise, diet and medication regimens, is an effective intervention to reduce blood glucose level in diabetic children.

  6. Dextrose in the banked blood products does not seem to affect the blood glucose levels in patients undergoing liver transplantation

    Institute of Scientific and Technical Information of China (English)

    Kwok-Wai Cheng; King-Wah Chiu; Shih-Hor Wang; Chih-Che Lin; Tsan-Shiun Lin; Yueh-Wei Liu; Bruno Jawan; Chao-Long Chen; Yu-Fan Cheng; Chia-chih Tseng; Chih-Hsien Wang; Yaw-Sen Chen; Chih-Chi Wang; Tung Liang Huang; Hock-Liew Eng

    2005-01-01

    AIM: Hyperglycemia commonly seen in liver transplantation (LT) has often been attributed to the dextrose in the storage solution of blood transfusion products. The purpose of the study is to compare the changes of the blood glucose levels in transfused and non-transfused patients during LT. METHODS: A retrospective study on 60 biliary pediatric patients and 16 adult patients undergoing LT was carried out. Transfused pediatric patients were included in Group Ⅰ (GI), those not transfused in Group Ⅱ (GⅡ). Twelve adult patients were not given transfusion and assigned to Group Ⅲ (GⅢ); whereas, four adult patients who received massive transfusion were assigned to Group Ⅳ (GⅣ). The blood glucose levels, volume of blood transfused, and the volume of crystalloid infused were recorded, compared and analyzed. RESULTS: Results showed that the changes in bloodglucose levels during LT for both non-transfused and minimally transfused pediatric groups and non-transfused and massively-transfused adult groups were almost the same. CONCLUSION: We conclude that blood transfusion does not cause significant changes in the blood glucose levels inthis study.

  7. Alterations in blood glucose levels under hyperinsulinemia affect accumbens dopamine

    OpenAIRE

    Bello, Nicholas T.; Hajnal, Andras

    2006-01-01

    Dopaminergic systems have been implicated in diabetes and obesity. Notwithstanding, the most basic relationship between dopamine and plasma insulin as well as glucose levels yet remains unknown. The present experiments were designed to investigate the effects of acute hyperinsulinemia on basal dopamine levels in the nucleus accumbens of the rat under chloral hydrate anesthesia using acute microdialysis in combination with the hyperinsulinemic-glycemic clamping procedure. In Experiment 1, each...

  8. Relationship of endothelial nitric oxide synthase gene polymorphism with blood pressure,lipid profile and blood glucose level

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    To study the relationship of the polymorphism of endothelial nitric oxide synthase(eNOS)gene and blood pressure,lipid profiles and blood glucose level.By using PCR-RFLP,the eNOS Glu298Asp gene polymorphism was detected in 184 patients with essential hypertension and 196 matched healthy individuals with normal blood pressure.Taking into account eNOS Glu298Asp polymorphisms,the relationship of blood pressure with triglycerides(TG),total cholesterol(TC),high density lipoprotein(HDL),low density lipoprotein(LDL)and blood glucose level was analyzed.The distribution of eNOS Glu298Asp polymorphism had no significant difference between different blood pressure groups and gender groups,but there was a significant difference between different age groups,diastolic blood pressure groups or BMI groups(P<0.05).Asp/Asp genotype significantly increased the risk of hypertension in individuals with serum TC above 5.4 mmol/L(P=0.03,OR=2.65).eNOSGlu298Asp polymorphism and serum lipid could synergistically modulate the blood pressure,eNOS Asp/Asp genotype could significantly increase the risk of hypertension in individuals with serum TC over 5.4 mmol/L,eNOS Glu298Asp in combination with serum TC could be used to predict the risk of hypertension.

  9. Profile of blood glucose and ultrastucture of beta cells pancreatic islet in alloxan compound induced rats

    OpenAIRE

    I Nyoman Suarsana; Priosoeryanto, B P; M. Bintang; T. Wresdiyati

    2010-01-01

    Diabetes is marked by elevated levels of blood glucose, and progressive changes of the structure of pancreatic islet histopathology. The objective of this research was to analyse the glucose level and histophatological feature in pancreatic islet in alloxan compound induced rats. A total of ten male Spraque Dawley rats of 2 months old were used in this study. The rats were divided into two groups: (1) negative control group (K-), and (2) positif induced alloxan group (diabetic group =DM). The...

  10. Blood Glucose Control in Type 1 Diabetes With a Bihormonal Bionic Endocrine Pancreas

    OpenAIRE

    Russell, Steven J.; El-Khatib, Firas H.; Nathan, David M.; Magyar, Kendra L.; Jiang, John; Damiano, Edward R.

    2012-01-01

    OBJECTIVE To test whether safe and effective glycemic control could be achieved in type 1 diabetes using a bihormonal bionic endocrine pancreas driven by a continuous glucose monitor in experiments lasting more than two days and including six high-carbohydrate meals and exercise as challenges to glycemic control. RESEARCH DESIGN AND METHODS Six subjects with type 1 diabetes and no endogenous insulin secretion participated in two 51-h experiments. Blood glucose was managed with a bionic endocr...

  11. The Association between Concentrations of Green Tea and Blood Glucose Levels

    OpenAIRE

    Maruyama, Koutatsu; ISO, Hiroyasu; Sasaki, Satoshi; Fukino, Yoko

    2008-01-01

    Our objective was to examine whether habitual green tea consumption is associated with blood glucose levels and other biomarkers of glucose metabolism. We conducted a cross-sectional study of 35 male volunteers, 23–63 years old and residing in Shizuoka Prefecture in Japan. Biochemical data were measured and we conducted a questionnaire survey on health, lifestyle, and nutrition, as well as frequency of consumption and concentrations (1%, 2%, and 3%) of green tea. Men who consumed a 3% concent...

  12. Cerebral blood flow, oxygen and glucose metabolism with PET in progressive supranuclear palsy

    Energy Technology Data Exchange (ETDEWEB)

    Otsuka, Makoto; Ichiya, Yuici; Kuwabara, Yasuo (Kyushu Univ., Fukuoka (Japan). Faculty of Medicine) (and others)

    1989-11-01

    Cerebral blood flow, cerebral oxygen metabolic rate and cerebral glucose metabolic rate were measured with positron emission tomography (PET) in four patients with progressive supranuclear palsy (PSP). Decreased blood flow and hypometabolism of oxygen and glucose were found in both subcortical and cortical regions, particularly in the striatum including the head of the caudate nucleus and the frontal cortex. The coupling between blood flow and metabolism was preserved even in the regions which showed decreased blood flow and hypometabolism. These findings indicated the hypofunction, as revealed by decreased blood flow and hypometablolism on PET, both in the striatum and the frontal cortex, and which may underlie the pathophysiological mechanism of motor and mental disturbance in PSP. (author).

  13. Cerebral blood flow, oxygen and glucose metabolism with PET in progressive supranuclear palsy

    International Nuclear Information System (INIS)

    Cerebral blood flow, cerebral oxygen metabolic rate and cerebral glucose metabolic rate were measured with positron emission tomography (PET) in four patients with progressive supranuclear palsy (PSP). Decreased blood flow and hypometabolism of oxygen and glucose were found in both subcortical and cortical regions, particularly in the striatum including the head of the caudate nucleus and the frontal cortex. The coupling between blood flow and metabolism was preserved even in the regions which showed decreased blood flow and hypometabolism. These findings indicated the hypofunction, as revealed by decreased blood flow and hypometablolism on PET, both in the striatum and the frontal cortex, and which may underlie the pathophysiological mechanism of motor and mental disturbance in PSP. (author)

  14. Mango Supplementation Improves Blood Glucose in Obese Individuals

    OpenAIRE

    Evans, Shirley F; Maureen Meister; Maryam Mahmood; Heba Eldoumi; Sandra Peterson; Penelope Perkins-Veazie; Clarke, Stephen L.; Mark Payton; Smith, Brenda J; Edralin A. Lucas

    2014-01-01

    This pilot study examined the effects of freeze-dried mango (Mangifera indica L.) supplementation on anthropometrics, body composition, and biochemical parameters in obese individuals. Twenty obese adults (11 males and 9 females) ages 20- to 50-years old, received 10 g/day of ground freeze-dried mango pulp for 12 weeks. Anthropometrics, biochemical parameters, and body composition were assessed at baseline and final visits of the study. After 12 weeks, mango supplementation significantly redu...

  15. The efficacy of karkadeh tea in controlling post-prandial blood glucose levels

    DEFF Research Database (Denmark)

    Harrison, Adrian Paul; Cooper, Ross Gordon; Suliman, Moustafa Ahmed;

    2009-01-01

    obesity. Approach: In order to investigate the efficacy of "karkadeh" Roselle-Hibiscus sabdariffa tea as a means of reducing post-prandial blood glucose levels in human subjects, 10g of dried karkadeh was brewed in 500ml of water, allowed to infuse for 60 min and imbibed along with a high glycemic index...... food. Results: Data show that in one individual, karkadeh tea taken in connection with a carbohydrate based breakfast meal resulted in a significant increase (17%; p<0.01) in blood glucose level cf. an ordinary breakfast tea 60 min after ingestion. Moreover, in a study involving eight individuals, a...... slower rise to maximum levels and a greater Area Under the Curve (AUC) in terms of blood glucose was noted for the karkadeh tea plus a high glycemic index food cf. that of water imbibition with an identical high glycemic food. Conclusions/Recommendations: Karkadeh tea appears to have an efffect in terms...

  16. Diabetes mellitus, fasting blood glucose concentration, and risk of vascular disease

    DEFF Research Database (Denmark)

    Sarwar, N; Gao, P; Seshasai, S R Kondapally;

    2010-01-01

    BACKGROUND: Uncertainties persist about the magnitude of associations of diabetes mellitus and fasting glucose concentration with risk of coronary heart disease and major stroke subtypes. We aimed to quantify these associations for a wide range of circumstances. METHODS: We undertook a meta...... markers. HRs for coronary heart disease were higher in women than in men, at 40-59 years than at 70 years and older, and with fatal than with non-fatal disease. At an adult population-wide prevalence of 10%, diabetes was estimated to account for 11% (10-12%) of vascular deaths. Fasting blood glucose......-analysis of individual records of diabetes, fasting blood glucose concentration, and other risk factors in people without initial vascular disease from studies in the Emerging Risk Factors Collaboration. We combined within-study regressions that were adjusted for age, sex, smoking, systolic blood pressure...

  17. Disposable glucose test strip for whole blood with integrated sensing/diffusion-limiting layer

    Energy Technology Data Exchange (ETDEWEB)

    Chen Zhencheng [Department of Biomedical Engineering, School of Info-Physics and Geomatics Engineering, Central South University, Changsha 410083 (China); Fang Cheng, E-mail: fangpingchuan@163.co [Department of Biomedical Engineering, School of Info-Physics and Geomatics Engineering, Central South University, Changsha 410083 (China); Wang Hongyan; He Jishan [Department of Biomedical Engineering, School of Info-Physics and Geomatics Engineering, Central South University, Changsha 410083 (China)

    2009-12-30

    A disposable glucose test strip with an integrated sensing/diffusion-limiting layer was developed. A formulation containing filler, glucose oxidase and electronic mediator was screen-printed over two carbon electrodes to form an integrated sensing/diffusion-limiting layer. On rehydration, the integrated layer does not break up, but swells to form a gelled and three-dimensional meshy reaction zone on the surface of the underlying conductive elements in which reactants and mediator move freely, but interfering species such as red blood cells containing oxygenated hemoglobin are excluded. On the same time, the integrated layer maintains a rate of permeation of the analyte through it with a variation of less than 10% at temperatures ranging from 15 deg. C to 42 deg. C. This biosensor is substantially insensitive to interferents and essentially independent to relevant temperature, which provides a more reliable reading of actual blood glucose value in human whole blood.

  18. Specificity of noninvasive blood glucose sensing using optical coherence tomography technique: a pilot study

    International Nuclear Information System (INIS)

    Noninvasive monitoring of blood glucose concentration in diabetic patients would significantly reduce complications and mortality associated with this disease. In this paper, we experimentally and theoretically studied specificity of noninvasive blood glucose monitoring with the optical coherence tomography (OCT) technique. OCT images and signals were obtained from skin of Yucatan micropigs and New Zealand rabbits. Obtained results demonstrate that: (1) several body osmolytes may change the refractive index mismatch between the interstitial fluid (ISF) and scattering centres in tissue, however the effect of the glucose is approximately one to two orders of magnitude higher; (2) an increase of the ISF glucose concentration in the physiological range (3-30 mM) may decrease the scattering coefficient by 0.22% mM-1 due to cell volume change; (3) stability of the OCT signal slope is dependent on tissue heterogeneity and motion artefacts; and (4) moderate skin temperature fluctuations (±1 deg. C) do not decrease accuracy and specificity of the OCT-based glucose sensor, however substantial skin heating or cooling (several deg. C) significantly change the OCT signal slope. These results suggest that the OCT technique may provide blood glucose concentration monitoring with sufficient specificity under normal physiological conditions

  19. Blood glucose responses of diabetes mellitus type II patients to some local fruits.

    Science.gov (United States)

    Guevarra, M T; Panlasigui, L N

    2000-12-01

    To determine the glucose responses of diabetes mellitus type II subjects to fruits, four locally available fruits (containing 25 g of available carbohydrates per serving portion) of chico, mango, pineapple, and papaya were tested among ten type II diabetic subjects, using wheat bread as the control. Results of the in vivo test indicated that chico and mango had significantly lower (P ≤ 0.05) blood glucose areas compared to wheat bread. Chico and mango also had a much lower glycemic index (GI), 57 and 59, respectively, compared to pineapple, 73 and papaya, 86. Differences in glucose responses to fruits and their varying GI are attributed to the amount of fiber, type and amount of sugars found, presence of antinutrients, acidity and physical characteristics of the fruits when chewed. The high fiber content of chico (7.9%), its fructose content (5.3%), its grainy texture when chewed and the presence of antinutrients (saponin, sapotin and achrasaponin) may contribute to its slow digestion and absorption. The low GI and blood glucose response of mango may be because of its fructose content (3.0%), acidity content (malic, citric and tartaric) and its phytic acid content (0.03%). Furthermore, starch, which is a possible factor contributing to low GI, is present in chico (0.8%) and mango (0.3%). Pineapple and papaya, the test fruits that elicited higher blood glucose responses and GI, have much lower fiber contents, less acids and contain glucose and sucrose sugars. PMID:24394507

  20. Investigating pipeline and state of the art blood glucose biosensors to formulate next steps.

    Science.gov (United States)

    Aggidis, Anthony G A; Newman, Jeffrey D; Aggidis, George A

    2015-12-15

    Ten years on from a review in the twentieth issue of this journal, this contribution assess the direction research in the field of glucose sensing for diabetes is headed and various technologies to be seen in the future. The emphasis of this review was placed on the home blood glucose testing market. After an introduction to diabetes and glucose sensing, this review analyses state of the art and pipeline devices; in particular their user friendliness and technological advancement. This review complements conventional reviews based on scholarly published papers in journals. PMID:26143465

  1. Impact of epidemic rates of diabetes on the Chinese blood glucose testing market.

    Science.gov (United States)

    Hu, Jamie; Zhang, Xian-En

    2011-09-01

    China has become the country with the largest diabetes mellitus population in the world since the 1990s. About 100 million diabetes cases have been diagnosed since 2008. Handheld blood glucose meters and test strips are urgently needed for daily patient measurement. The glucose monitor with a screen-printed carbon-based glucose electrode has been in commercial production since 1994. Since then, approximately 20 companies have been involved in manufacturing and marketing meters and test strips in China. The current market and production volume and updates on technology issues are discussed in this article. PMID:22027332

  2. Low Red Blood Cell Vitamin C Concentrations Induce Red Blood Cell Fragility: A Link to Diabetes Via Glucose, Glucose Transporters, and Dehydroascorbic Acid

    Directory of Open Access Journals (Sweden)

    Hongbin Tu

    2015-11-01

    Full Text Available Strategies to prevent diabetic microvascular angiopathy focus on the vascular endothelium. Because red blood cells (RBCs are less deformable in diabetes, we explored an original concept linking decreased RBC deformability to RBC ascorbate and hyperglycemia. We characterized ascorbate concentrations from human and mouse RBCs and plasma, and showed an inverse relationship between RBC ascorbate concentrations and deformability, measured by osmotic fragility. RBCs from ascorbate deficient mice were osmotically sensitive, appeared as spherocytes, and had decreased β-spectrin. These aberrancies reversed with ascorbate repletion in vivo. Under physiologic conditions, only ascorbate's oxidation product dehydroascorbic acid (DHA, a substrate for facilitated glucose transporters, was transported into mouse and human RBCs, with immediate intracellular reduction to ascorbate. In vitro, glucose inhibited entry of physiologic concentrations of dehydroascorbic acid into mouse and human RBCs. In vivo, plasma glucose concentrations in normal and diabetic mice and humans were inversely related to respective RBC ascorbate concentrations, as was osmotic fragility. Human RBC β-spectrin declined as diabetes worsened. Taken together, hyperglycemia in diabetes produced lower RBC ascorbate with increased RBC rigidity, a candidate to drive microvascular angiopathy. Because glucose transporter expression, DHA transport, and its inhibition by glucose differed for mouse versus human RBCs, human experimentation is indicated.

  3. A comprehensive evaluation of strip performance in multiple blood glucose monitoring systems.

    Science.gov (United States)

    Katz, Laurence B; Macleod, Kirsty; Grady, Mike; Cameron, Hilary; Pfützner, Andreas; Setford, Steven

    2015-05-01

    Accurate self-monitoring of blood glucose is a key component of effective self-management of glycemic control. Accurate self-monitoring of blood glucose results are required for optimal insulin dosing and detection of hypoglycemia. However, blood glucose monitoring systems may be susceptible to error from test strip, user, environmental and pharmacological factors. This report evaluated 5 blood glucose monitoring systems that each use Verio glucose test strips for precision, effect of hematocrit and interferences in laboratory testing, and lay user and system accuracy in clinical testing according to the guidelines in ISO15197:2013(E). Performance of OneTouch(®) VerioVue™ met or exceeded standards described in ISO15197:2013 for precision, hematocrit performance and interference testing in a laboratory setting. Performance of OneTouch(®) Verio IQ™, OneTouch(®) Verio Pro™, OneTouch(®) Verio™, OneTouch(®) VerioVue™ and Omni Pod each met or exceeded accuracy standards for user performance and system accuracy in a clinical setting set forth in ISO15197:2013(E). PMID:25702769

  4. Effect of cinnamon extract on blood glucose level and lipid profile in alloxan induced diabetic rats

    International Nuclear Information System (INIS)

    Background: Cinnamon has been shown to potentiate the hypoglycaemic effect of insulin through up regulation of the glucose uptake in cultured adipocytes of rats. This study tried to find out the effect of Cinnamon alone or in combination with Insulin in diabetic albino rats. Methods: Thirty rats were divided into three groups, A and B. Group A were given cinnamon extract 200 mg/Kg body weight daily orally and group B rats were given cinnamon extract 400 mg/Kg body weight daily. After six weeks blood glucose and lipid profile levels were evaluated in all the groups. Results: Group of rats given 200 mg cinnamon extract showed significant decrease of blood glucose concentration but there was slight or no change in the level of lipid parameters including serum cholesterol, triglyceride and lipoproteins (HDL, LDL-chol). On the other hand group of rats given 400 mg extract of cinnamon showed a better but non significant change in level of lipid related parameter while blood glucose level was significantly decreased. Conclusion: The cinnamon at a dose of 400 mg showed same effects on blood glucose level but better effects on lipid profiles especially of serum cholesterol level of group of rats compared to 200 mg of cinnamon extract. Cinnamon may be recommended as hypoglycaemic herb but not as hypolipidaemic herb. (author)

  5. System accuracy of blood glucose monitoring systems: impact of use by patients and ambient conditions.

    Science.gov (United States)

    Schmid, Christina; Haug, Cornelia; Heinemann, Lutz; Freckmann, Guido

    2013-10-01

    For self-monitoring of blood glucose by people with diabetes, the reliability of the measured blood glucose values is a prerequisite in order to ensure correct therapeutic decisions. Requirements for system accuracy are defined by the International Organization for Standardization (ISO) in the standard EN ISO 15197:2003. However, even a system with high analytical quality is not a guarantee for accurate and reliable measurement results. Under routine life conditions, blood glucose measurement results are affected by several factors. First, the act of performing measurements as well as the handling of the system may entail numerous possible error sources, such as traces of glucose-containing products on the fingertips, the use of deteriorated test strips, or the incorrect storage of test strips. Second, ambient and sampling conditions such as high altitude, partial pressure of oxygen, ambient temperature, and the use of alternate test sites can have an influence on measurement results. Therefore, the user-friendliness of a system and the quality of the manufacturer's labeling to reduce the risk of handling errors are also important aspects in ensuring reliable and accurate measurement results. In addition, the analytical performance of systems should be less prone to user errors and ambient conditions. Finally, people with diabetes must be aware of the information and instructions in the manufacturer's labeling and must be able to measure and interpret blood glucose results correctly. PMID:23883407

  6. Short-term application of low-dose growth hormone in surgical patients: Effects on nitrogen balance and blood glucose

    Institute of Scientific and Technical Information of China (English)

    Ming-Ming Zhang; Xiao-Ting Wu; Yong Zhou; Kun Qian; Ya-Min Zheng

    2007-01-01

    AIM: To investigate the effectiveness and safety of recombinant human growth hormone (rhGH) in postoperative patients.METHODS: A total of 48 consecutive patients undergoing abdominal operations were randomized to receive either subcutaneous rhGH (0.15 IU/kg) or placebo (menstruum) injections daily for 7 d after surgery. The two groups had similar nutritional intake. Blood samples for serum fibronectin, albumin, prealbumin, transferrin and the total lymphocyte count, as well as glucose levels were collected to study the rhGH effect. Basal laboratory evaluation, and nutritional status were estimated on d 1before as baseline and d 3 and 10 after operation using standard laboratory techniques. Nitrogen balance was measured from d 3 to 9 after operation.RESULTS: The cumulative nitrogen balance was significantly improved in rhGH group compared with the placebo group (11.37±16.82 vs -9.11±17.52, P = 0.0003).Serum fibronectin was also significantly higher in the rhGH group than in the placebo group (104.77±19.94vs 93.03±16.03, P<0.05), whereas changes in serum albumin, prealbumin, transferrin and total lymphocyte counts were not statistically significant. Mean blood glucose levels were significantly higher in the rhGH group from d 3 to 6 after operation.CONCLUSION: If blood glucose can be controlled, lowdose growth hormone together with hypocaloric nutrition is effective on improving positive nitrogen balance and protein conservation and safe is in postoperative patients.

  7. Lanthanides' enhancing absorption of insulin and reduction of blood glucose of rat by pulmonary administration

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    To explore the possibility of lanthanides as the enhancer of insulin absorption, the promoting effects of lanthanide ions on the absorption of intrapulmonary delivered insulin and reduction of blood glucose were investigated by means of two approaches, preadministration and coadministration of lanthanide ions with insulin. The results indicate that, compared with the results of those given insulin only, lanthanide ions can effectively enhance the level of insulin and the reduction of glucose level in blood. These effects are dependent on lanthanide species and their concentrations. The mechanism was discussed.

  8. Clinical utility and accuracy of a blood glucose meter for the detection of neonatal hypoglycemia

    International Nuclear Information System (INIS)

    Objective: To determine the accuracy and reliability of a glucometer in comparison to hexokinase method in detecting neonatal hypoglycemia. Subjects and Methods: All neonates presenting with known risk factors or suggestive clinical features were screened for hypoglycemia by using capillary blood on Accutrend alpha glucometer. Simultaneously the venous blood glucose values were done on Hitachi 902 autoanalyser by hexokinase method. A level of 40 mg/dl or less was taken as neonatal hypoglycemia. Results: A total of 292-paired samples were taken from 223 neonates. Hypoglycemia was detected in 112 samples (38.4%). Correlation of glucometer values with laboratory values of blood glucose levels was excellent throughout the range with coefficient of correlation (r) of 0.976 (p-value < 0.001). For blood glucose values equal or less than 40 mg/dl, r was 0.547 (p-value < 0.001). The instrument used showed a sensitivity of 98% and specificity of 93% to detect neonatal hypoglycemia (equal or less than 40 mg/dl) with a positive predictive value of 88% and negative predictive value 99%. Conclusion: The blood glucose reflectance meter can be a useful and accurate instrument for screening and detecting neonatal hypoglycemia in symptomatic babies under stress. All low values by glucometer should be promptly analyzed and confirmed by chemical laboratory. (author)

  9. Low perfusion index affects the difference in glucose level between capillary and venous blood

    Directory of Open Access Journals (Sweden)

    Acar N

    2014-11-01

    Full Text Available Nurdan Acar,1 Hamit Ozcelik,1 Arif Alper Cevik,1 Engin Ozakin,1 Goknur Yorulmaz,2 Nur Kebapci,2 Ugur Bilge,3 Muzaffer Bilgin4 1Emergency Department, 2Endocrinology Department, 3Family Medicine Department, 4Biostatistics Department, Medical School, Eskisehir Osmangazi University, Eskisehir, Turkey Aim: In emergency cases, finger stick testing is primarily used to check the blood glucose value of patients since it takes longer to obtain the venous value. In critical patients, under conditions that cause an increase in metabolic state and level of stress, there occurs considerable difference in glucose levels between capillary and venous measurements. This study aimed to investigate the comparability of capillary and venous glucose values, according to the perfusion index level obtained with the Masimo Radical-7® device, in critical patients aged 18 years and over.Method: We conducted this prospective and observational study in the emergency department of the Eskisehir Osmangazi University hospital between November 3, 2008 and February 2, 2009.Results: The blood glucose of 300 critical patients was checked by finger stick in the emergency unit. The participants with normal vital signs had perfusion index between 0 and 5; the results obtained by the two methods were more consistent for perfusion index values of 6 and over. The results were most consistent in aged participants with normal vital sign findings and low perfusion index and in young patients with high perfusion index. In the cases where at least one of the vital signs was abnormal, the glucose values obtained by the two methods were more consistent when the perfusion index was 6 or over. In this group, independently from the perfusion index value, the consistency was higher in younger patients compared with aged patients.Conclusion: In the emergency department, perfusion index value measured by Masimo Radical-7 and capillary blood glucose levels can serve in blood sugar management in

  10. Blood glucose levels and cortical thinning in cognitively normal, middle-aged adults.

    Science.gov (United States)

    Wennberg, Alexandra M V; Spira, Adam P; Pettigrew, Corinne; Soldan, Anja; Zipunnikov, Vadim; Rebok, George W; Roses, Allen D; Lutz, Michael W; Miller, Michael M; Thambisetty, Madhav; Albert, Marilyn S

    2016-06-15

    Type II diabetes mellitus (DM) increases risk for cognitive decline and is associated with brain atrophy in older demented and non-demented individuals. We investigated (1) the cross-sectional association between fasting blood glucose level and cortical thickness in a sample of largely middle-aged, cognitively normal adults, and (2) whether these associations were modified by genes associated with both lipid processing and dementia. To explore possible modifications by genetic status, we investigated the interaction between blood glucose levels and the apolipoprotein E (APOE) ε4 allele and the translocase of the outer mitochondrial membrane (TOMM) 40 '523 genotype on cortical thickness. Cortical thickness measures were based on mean thickness in a subset of a priori-selected brain regions hypothesized to be vulnerable to atrophy in Alzheimer's disease (AD) (i.e., 'AD vulnerable regions'). Participants included 233 cognitively normal subjects in the BIOCARD study who had a measure of fasting blood glucose and cortical thickness measures, quantified by magnetic resonance imaging (MRI) scans. After adjustment for age, sex, race, education, depression, and medical conditions, higher blood glucose was associated with thinner parahippocampal gyri (B=-0.002; 95% CI -0.004, -0.0004) and temporal pole (B=-0.002; 95% CI -0.004, -0.0001), as well as reduced average thickness over AD vulnerable regions (B=-0.001; 95% CI -0.002, -0.0001). There was no evidence for greater cortical thinning in ε4 carriers of the APOE gene or in APOE ε3/3 individuals carrying the TOMM40 VL/VL genotypes. When individuals with glucose levels in the diabetic range (≥126mg/dL), were excluded from the analysis, the associations between glucose levels and cortical thickness were no longer significant. These findings suggest that glucose levels in the diabetic range are associated with reduced cortical thickness in AD vulnerable regions as early as middle age. PMID:27206882

  11. Effects of MDMA on blood glucose levels and brain glucose metabolism

    OpenAIRE

    Soto-Montenegro, M L; Vaquero, Juan José; Arango, C.; Ricaurte, G.; García-Barreno, P; Desco, Manuel

    2007-01-01

    Purpose This study was designed to assess changes in glucose metabolism in rats administered single or repeated doses of MDMA. Methods Two different experiments were performed: (1) A single-dose study with four groups receiving 20 mg/kg, 40 mg/kg, saline or heat, and (2) a repeated-dose study with two groups receiving three doses, at intervals of 2 h, of 5 mg/kg or saline. Rats were imaged using a dedicated small-animal PET scanner 1 h after single-dose administration or 7 days after repeated...

  12. Optimal Control of Blood Glucose: The Diabetic Patient or the Machine?

    OpenAIRE

    Brown, Larry; Edelman, Elazer R.

    2010-01-01

    In this issue of Science Translational Medicine, El-Khatib et al. describe a “closed-loop” bi-hormonal artificial pancreas, designed to avert episodes of low blood sugar in patients with insulin-dependent diabetes. We discuss the benefits and challenges of therapy directed at tight control of blood glucose and ask whether this and similar technological breakthroughs can address as yet unanswered questions in the biology of diabetes.

  13. Changes in blood pressure and body weight over ten years in men selected for glucose intolerance.

    OpenAIRE

    Jarrett, R J; Keen, H; Murrells, T

    1987-01-01

    Relative changes in body weight and blood pressure over ten years of observation are reported in men recruited for a trial of therapy in relation to the natural history of glucose intolerance. Half were recommended a diet restricting carbohydrate to 120 g daily (diet group) and half were recommended to 'limit use of table sugar' (no diet). In both groups average weight and blood pressure fell over the 12 to 18 months after treatment allocation, the decline being proportionately greater for bo...

  14. Melatonin Signaling Controls the Daily Rhythm in Blood Glucose Levels Independent of Peripheral Clocks.

    Directory of Open Access Journals (Sweden)

    Sharon Owino

    Full Text Available Melatonin is rhythmically secreted by both the pineal gland and retina in a circadian fashion, with its peak synthesis occurring during the night. Once synthesized, melatonin exerts its effects by binding to two specific G-protein coupled receptors-melatonin receptor type 1(MT1 and melatonin receptor type 2(MT2. Recent studies suggest the involvement of MT1 and MT2 in the regulation of glucose homeostasis; however the ability of melatonin signaling to impart timing cues on glucose metabolism remains poorly understood. Here we report that the removal of MT1 or MT2 in mice abolishes the daily rhythm in blood glucose levels. Interestingly, removal of melatonin receptors produced small effects on the rhythmic expression patterns of clock genes within skeletal muscle, liver, and adipose tissue. Taken together, our data suggest that the loss of the daily rhythm in blood glucose observed in MT1(-/- and MT2(-/- mice does not occur as a consequence of 'disrupted' clocks within insulin sensitive tissues. Finally our results highlight a diurnal contribution of melatonin receptor signaling in the daily regulation of blood glucose levels.

  15. Lithium modulates the chronic stress-induced effect on blood glucose level of male rats

    Directory of Open Access Journals (Sweden)

    Popović Nataša

    2010-01-01

    Full Text Available In the present study we examined gross changes in the mass of whole adrenal glands and that of the adrenal cortex, as well as the serum corticosterone and glucose level of mature male Wistar rats subjected to three different treatments: animals subjected to chronic restraint-stress, animals injected with lithium (Li and chronically stressed rats treated with Li. Under all three conditions we observed hypertrophy of whole adrenals, as well as the adrenal cortices. Chronic restraint stress, solely or in combination with Li treatment, significantly elevated the corticosterone level, but did not change the blood glucose level. Animals treated only with Li exhibited an elevated serum corticosterone level and blood glucose level. The aim of our study was to investigate the modulation of the chronic stress-induced effect on the blood glucose level by lithium, as a possible mechanism of avoiding the damage caused by chronic stress. Our results showed that lithium is an agent of choice which may help to reduce stress-elevated corticosterone and replenish exhausted glucose storages in an organism.

  16. Early blood glucose profile and neurodevelopmental outcome at two years in neonatal hypoxic-ischaemic encephalopathy

    LENUS (Irish Health Repository)

    Nadeem, Montasser

    2011-02-04

    Abstract Background To examine the blood glucose profile and the relationship between blood glucose levels and neurodevelopmental outcome in term infants with hypoxic-ischaemic encephalopathy. Methods Blood glucose values within 72 hours of birth were collected from 52 term infants with hypoxic-ischaemic encephalopathy. Hypoglycaemia [< 46.8 mg\\/dL (2.6 mmol\\/L)] and hyperglycaemia [> 150 mg\\/dL (8.3 mmol\\/L)] were correlated to neurodevelopmental outcome at 24 months of age. Results Four fifths of the 468 blood samples were in the normoglycaemic range (392\\/468:83.8%). Of the remaining 76 samples, 51.3% were in the hypoglycaemic range and (48.7%) were hyperglycaemic. A quarter of the hypoglycaemic samples (28.2%:11\\/39) and a third of the hyperglycaemic samples (32.4%:12\\/37) were recorded within the first 30 minutes of life. Mean (SD) blood glucose values did not differ between infants with normal and abnormal outcomes [4.89(2.28) mmol\\/L and 5.02(2.35) mmol\\/L, p value = 0.15] respectively. In term infants with hypoxic-ischaemic encephalopathy, early hypoglycaemia (between 0-6 hours of life) was associated with adverse outcome at 24 months of age [OR = 5.8, CI = 1.04-32)]. On multivariate analysis to adjust for grade of HIE this association was not statistically significant. Late hypoglycaemia (6-72 hours of life) was not associated with abnormal outcome [OR = 0.22, CI (0.04-1.14)]. The occurrence of hyperglycaemia was not associated with adverse outcome. Conclusion During the first 72 hours of life, blood glucose profile in infants with hypoxic-ischaemic encephalopathy varies widely despite a management protocol. Early hypoglycaemia (0-6 hours of life) was associated with severe HIE, and thereby; adverse outcome.

  17. Early blood glucose profile and neurodevelopmental outcome at two years in neonatal hypoxic-ischaemic encephalopathy.

    LENUS (Irish Health Repository)

    Nadeem, Montasser

    2012-01-31

    BACKGROUND: To examine the blood glucose profile and the relationship between blood glucose levels and neurodevelopmental outcome in term infants with hypoxic-ischaemic encephalopathy. METHODS: Blood glucose values within 72 hours of birth were collected from 52 term infants with hypoxic-ischaemic encephalopathy. Hypoglycaemia [< 46.8 mg\\/dL (2.6 mmol\\/L)] and hyperglycaemia [> 150 mg\\/dL (8.3 mmol\\/L)] were correlated to neurodevelopmental outcome at 24 months of age. RESULTS: Four fifths of the 468 blood samples were in the normoglycaemic range (392\\/468:83.8%). Of the remaining 76 samples, 51.3% were in the hypoglycaemic range and (48.7%) were hyperglycaemic. A quarter of the hypoglycaemic samples (28.2%:11\\/39) and a third of the hyperglycaemic samples (32.4%:12\\/37) were recorded within the first 30 minutes of life. Mean (SD) blood glucose values did not differ between infants with normal and abnormal outcomes [4.89(2.28) mmol\\/L and 5.02(2.35) mmol\\/L, p value = 0.15] respectively. In term infants with hypoxic-ischaemic encephalopathy, early hypoglycaemia (between 0-6 hours of life) was associated with adverse outcome at 24 months of age [OR = 5.8, CI = 1.04-32)]. On multivariate analysis to adjust for grade of HIE this association was not statistically significant. Late hypoglycaemia (6-72 hours of life) was not associated with abnormal outcome [OR = 0.22, CI (0.04-1.14)]. The occurrence of hyperglycaemia was not associated with adverse outcome. CONCLUSION: During the first 72 hours of life, blood glucose profile in infants with hypoxic-ischaemic encephalopathy varies widely despite a management protocol. Early hypoglycaemia (0-6 hours of life) was associated with severe HIE, and thereby; adverse outcome.

  18. Higher blood glucose level associated with body mass index and gut microbiota in elderly people

    Science.gov (United States)

    Sepp, Epp; Kolk, Helgi; Lõivukene, Krista; Mikelsaar, Marika

    2014-01-01

    Background Some dominant bacterial divisions of the intestines have been linked to metabolic diseases such as overweight and diabetes. Objective A pilot study aimed to evaluate the relations between the culturable intestinal bacteria with body mass index (BMI) and some principal cellular and metabolic markers of blood in people older than 65. Design Altogether 38 generally healthy elderly people were recruited: ambulatory (n=19) and orthopedic surgery (n=19). Questionnaires on general health, anthropometric measurements, routine clinical and laboratory data, and quantitative composition of cultivable gut microbiota were performed. Results Blood glucose level was positively correlated with BMI (r=0.402; p=0.014). Higher blood glucose level had negative correlation with relative share of intestinal anaerobic bacteria such as bacteroides (r=−0.434; p=0.0076) and gram-positive anaerobic cocci (r=−0.364; p=0.027). In contrast, the relative share of bifidobacteria (r=0.383; p=0.019) and staphylococci (r=0.433; p=0.008) was positively correlated to blood glucose level. In elderly people, a higher blood glucose concentration was predicted by the reduction of the anaerobes’ proportion (adj. sex, age, and BMI R2=0.192, p=0.028) and that of Bacteroides sp. (adj. R2=0.309, p=0.016). Conclusion A tight interplay between increased BMI, level of blood glucose, and the reduced proportion of cultivable bacteroides is taking place in the gut microbiota of elderly people. PMID:24936169

  19. Higher blood glucose level associated with body mass index and gut microbiota in elderly people

    Directory of Open Access Journals (Sweden)

    Epp Sepp

    2014-06-01

    Full Text Available Background: Some dominant bacterial divisions of the intestines have been linked to metabolic diseases such as overweight and diabetes. Objective: A pilot study aimed to evaluate the relations between the culturable intestinal bacteria with body mass index (BMI and some principal cellular and metabolic markers of blood in people older than 65. Design: Altogether 38 generally healthy elderly people were recruited: ambulatory (n=19 and orthopedic surgery (n=19. Questionnaires on general health, anthropometric measurements, routine clinical and laboratory data, and quantitative composition of cultivable gut microbiota were performed. Results: Blood glucose level was positively correlated with BMI (r=0.402; p=0.014. Higher blood glucose level had negative correlation with relative share of intestinal anaerobic bacteria such as bacteroides (r=−0.434; p=0.0076 and gram-positive anaerobic cocci (r=−0.364; p=0.027. In contrast, the relative share of bifidobacteria (r=0.383; p=0.019 and staphylococci (r=0.433; p=0.008 was positively correlated to blood glucose level. In elderly people, a higher blood glucose concentration was predicted by the reduction of the anaerobes’ proportion (adj. sex, age, and BMI R2=0.192, p=0.028 and that of Bacteroides sp. (adj. R2=0.309, p=0.016. Conclusion: A tight interplay between increased BMI, level of blood glucose, and the reduced proportion of cultivable bacteroides is taking place in the gut microbiota of elderly people.

  20. Non-invasive blood glucose monitoring with Raman spectroscopy: prospects for device miniaturization

    Science.gov (United States)

    Wróbel, M. S.

    2016-01-01

    The number of patients with diabetes has reached over 350 million, and still continues to increase. The need for regular blood glucose monitoring sparks the interest in the development of modern detection technologies. One of those methods, which allows for noninvasive measurements, is Raman spectroscopy. The ability of infrared light to penetrate deep into tissues allows for obtaining measurements through the skin without its perforation. This paper presents the limitations and possibilities of non-invasive blood glucose monitoring with Raman spectroscopy. Especially focusing on the possibilities for device miniaturization. Such device incorporates a Raman spectrometer, a fiber-optical probe, and a computing device (microcontroller, smartphone, etc.) which calculates the glucose concentration using specialized algorithms. Simplification of device design, as well as turbidity correction technique and a new proposed method of synchronized detection are described.

  1. Correlation of salivary glucose, blood glucose and oral candidal carriage in the saliva of type 2 diabetics: A case-control study

    Directory of Open Access Journals (Sweden)

    Satish Kumar

    2014-01-01

    Full Text Available Objectives: To study the correlation between blood glucose levels and salivary glucose levels in type 2 diabetic patients, to study the relationship between salivary glucose levels and oral candidal carriage in type 2 diabetic patients and to determine whether salivary glucose levels could be used as a noninvasive tool for the measurement of glycemic control in type 2 diabetics. Study Design: The study population consisted of three groups: Group 1 consisted of 30 controlled diabetics and Group 2 consisted of 30 uncontrolled diabetics based on their random nonfasting plasma glucose levels. Group 3 consisted of 30 healthy controls. Two milliliters of peripheral blood was collected for the estimation of random nonfasting plasma glucose levels and glycosylated hemoglobin (HbA1c. Unstimulated saliva was collected for the estimation of salivary glucose. Saliva was collected by the oral rinse technique for the estimation of candidal counts. Results: The salivary glucose levels were significantly higher in controlled and uncontrolled diabetics when compared with controls. The salivary candidal carriage was also significantly higher in uncontrolled diabetics when compared with controlled diabetics and nondiabetic controls. The salivary glucose levels showed a significant correlation with blood glucose levels, suggesting that salivary glucose levels can be used as a monitoring tool for predicting glycemic control in diabetic patients. Conclusion: The present study found that estimation of salivary glucose levels can be used as a noninvasive, painless technique for the measurement of diabetic status of a patient in a dental set up. Increased salivary glucose levels leads to increased oral candidal carriage; therefore, oral diagnosticians are advised to screen the diabetic patients for any oral fungal infections and further management.

  2. Bihormonal control of blood glucose in people with type 1 diabetes

    DEFF Research Database (Denmark)

    Batora, Vladimir; Tárnik, Marían; Murgaš, Ján;

    2015-01-01

    This paper presents a bihormonal artificial pancreas (AP) for people with type 1 diabetes (T1D) designed to provide a safe blood glucose control with minimal use of glucagon. The control algorithm uses insulin as well as glucagon to prevent hyper- and hypoglycemia. We employ a novel prediction...... predicts hypoglycemia. Predictions utilize an ARMAX model describing glucose-insulin and glucose-glucagon dynamics. The model parameters are estimated from basic patient-specific data. A continuous glucose monitor provides feedback. We test the control algorithm using a simulation model with time......-based activation of glucagon administration. The control algorithm consists of a Kalman filter, an insulin infusion model predictive controller (MPC), a proportional-derivative (PD) controller for glucagon infusion, and a meal time insulin bolus calculator. The PD controller is activated if the Kalman filter...

  3. The Effect of Blood Glucose Self-Monitoring Among Inmates With Diabetes.

    Science.gov (United States)

    Hunter Buskey, Robin N; Mathieson, Kathleen; Leafman, Joan S; Feinglos, Mark N

    2015-10-01

    The increasing prevalence and risk of complications from diabetes necessitate patient participation and attentiveness to select appropriate foods, perform regular physical activity, and be active in diabetes management and self-maintenance. Diabetes is often largely asymptomatic; consequently, early diagnosis and treatment are necessary. Inmates are a unique population challenged by the increased prevalence of chronic conditions including diabetes. Diabetes standards for inmates contain diagnostic and treatment management guidelines that incorporate personal glucose monitoring for insulin users. In December 2009, the Federal Bureau of Prisons initiated a program to distribute glucose meters to insulin-dependent inmates to facilitate self-monitoring blood glucose. The purpose of this study was to evaluate the effect of these glucose meters on hemoglobin A1c levels. PMID:26276137

  4. Visual detection of blood glucose based on peroxidase-like activity of WS2 nanosheets.

    Science.gov (United States)

    Lin, Tianran; Zhong, Liangshuang; Song, Zhiping; Guo, Liangqia; Wu, Hanyin; Guo, Qingquan; Chen, Ying; Fu, FengFu; Chen, Guonan

    2014-12-15

    Tungsten disulfide (WS2) nanosheets were discovered to possess intrinsic peroxidase-like activity and catalyze the peroxidase substrate 3,3',5,5'-tetramethylbenzidine (TMB) to produce a color reaction in the presence of H2O2. Based on this finding, a colorimetric method and a portable test kit for the visual detection of blood glucose have been developed by using glucose oxidase (GOx) and WS2 nanosheets-catalyzed reactions. The linear range for glucose was ranged from 5 to 300 μM (R(2)=0.999) with the detection limit of 2.9 μM. The portable test kit was successfully evaluated glucose levels in serum samples from normal persons and diabetes persons by the observable color change from pale yellow to yellow-green, blue-green. PMID:25032681

  5. Feasibility of non-invasive optical blood-glucose detection using overtone circular dichroism

    CERN Document Server

    Hokr, Brett H; Meng, Zhaokai; Petrov, Georgi I; Yakovlev, Vladislav V

    2016-01-01

    Diabetes is one of the most debilitating and costly diseases currently plaguing humanity. It is a leading cause of death and dismemberment in the world, and we know how to treat it. Accurate, continuous monitoring and control of blood glucose levels via insulin treatments are widely known to mitigate the majority of detrimental effects caused by the disease. The primary limitation of continuous glucose monitoring is patient non-compliance due to the unpleasant nature of "finger-stick" testing methods. This limitation can be largely, or even completely, removed by non-invasive testing methods. In this report, we demonstrate the vibrational overtone circular dichroism properties of glucose and analyze its use as a method of non-invasive glucose monitoring, capable of assuaging this trillion dollar scourge.

  6. A Method for Manipulating Blood Glucose and Measuring Resulting Changes in Cognitive Accessibility of Target Stimuli.

    Science.gov (United States)

    Prokosch, Marjorie L; Hill, Sarah E

    2016-01-01

    Much research in social psychology has investigated the impact of bodily energy need on cognition and decision-making. As such, blood glucose, the body's primary energy source, has been of special interest to researchers for years. Fluctuations in blood glucose have been linked to a variety of changes in cognitive and behavioral processes, such as self-control, political attitudes, and eating behavior. To help meet growing interest in the links between bodily energy need and these processes, this manuscript offers a simple methodology to experimentally manipulate blood glucose using a fasting procedure followed by administration of a sugar-sweetened, unsweetened, or artificially-sweetened beverage. This is followed by presentation of a method for measuring resulting changes in implicit cognition using a lexical decision-task. In this task, participants are asked to identify whether strings of letters are words or non-words and response latencies are recorded. Sample results from a recent publication are presented as an example of the applications for the experimental manipulation of blood glucose and the lexical decision task measures. PMID:27585282

  7. Cinnamon intake lowers fasting blood glucose: an updated meta-analysis

    Science.gov (United States)

    OBJECTIVE – To determine if meta-analysis of recent clinical studies of cinnamon intake by people with Type II diabetes and/or prediabetes resulted in significant changes in fasting blood glucose. RESEARCH DESIGN AND METHODS -- Published clinical studies were identified using a literature search (P...

  8. What do professionals recommend regarding the frequency of self-monitoring of blood glucose?

    NARCIS (Netherlands)

    Hortensius, J.; Kleefstra, N.; Houweling, S. T.; van der Bijl, J. J.; Gans, R. O. B.; Bilo, H. J. G.

    2012-01-01

    Background: Patients' adherence to guidelines regarding self-monitoring of blood glucose (SMBG) is limited. However, there are no previous reports about the recommendations that are given in clinical practice concerning SMBG. The aim of this study was to investigate what healthcare providers recomme

  9. Blood Glucose Monitoring as a Teaching Tool for Endocrinology: A New Perspective

    Science.gov (United States)

    Moats, Robert K., II

    2009-01-01

    The education of new allied health professionals and nurses in proper endocrine evaluation and care has become critical in recent years, especially considering the greatly increased prevalence of diabetes in adults and children. The evaluation of blood glucose levels in human volunteers over time is a powerful teaching tool for endocrinology that…

  10. Higher Blood Glucose within the Normal Range Is Associated with More Severe Strokes

    DEFF Research Database (Denmark)

    Martin, Rolf J; Ratan, Rajiv R; Reding, Michael J;

    2012-01-01

    Background. Higher fasting blood glucose (FBG) concentrations in the hyperglycemic range are associated with more severe strokes. Whether this association also extends into patients with FBG in the normoglycemic range is unclear. We studied the association of stroke severity and FBG in normoglyce...

  11. Comprehensive Experiment--Clinical Biochemistry: Determination of Blood Glucose and Triglycerides in Normal and Diabetic Rats

    Science.gov (United States)

    Jiao, Li; Xiujuan, Shi; Juan, Wang; Song, Jia; Lei, Xu; Guotong, Xu; Lixia, Lu

    2015-01-01

    For second year medical students, we redesigned an original laboratory experiment and developed a combined research-teaching clinical biochemistry experiment. Using an established diabetic rat model to detect blood glucose and triglycerides, the students participate in the entire experimental process, which is not normally experienced during a…

  12. Impairment of brain endothelial glucose transporter by methamphetamine causes blood-brain barrier dysfunction

    Directory of Open Access Journals (Sweden)

    Murrin L Charles

    2011-03-01

    Full Text Available Abstract Background Methamphetamine (METH, an addictive psycho-stimulant drug with euphoric effect is known to cause neurotoxicity due to oxidative stress, dopamine accumulation and glial cell activation. Here we hypothesized that METH-induced interference of glucose uptake and transport at the endothelium can disrupt the energy requirement of the blood-brain barrier (BBB function and integrity. We undertake this study because there is no report of METH effects on glucose uptake and transport across the blood-brain barrier (BBB to date. Results In this study, we demonstrate that METH-induced disruption of glucose uptake by endothelium lead to BBB dysfunction. Our data indicate that a low concentration of METH (20 μM increased the expression of glucose transporter protein-1 (GLUT1 in primary human brain endothelial cell (hBEC, main component of BBB without affecting the glucose uptake. A high concentration of 200 μM of METH decreased both the glucose uptake and GLUT1 protein levels in hBEC culture. Transcription process appeared to regulate the changes in METH-induced GLUT1 expression. METH-induced decrease in GLUT1 protein level was associated with reduction in BBB tight junction protein occludin and zonula occludens-1. Functional assessment of the trans-endothelial electrical resistance of the cell monolayers and permeability of dye tracers in animal model validated the pharmacokinetics and molecular findings that inhibition of glucose uptake by GLUT1 inhibitor cytochalasin B (CB aggravated the METH-induced disruption of the BBB integrity. Application of acetyl-L-carnitine suppressed the effects of METH on glucose uptake and BBB function. Conclusion Our findings suggest that impairment of GLUT1 at the brain endothelium by METH may contribute to energy-associated disruption of tight junction assembly and loss of BBB integrity.

  13. Baseline heavy metals and metalloid values in blood of loggerhead turtles (Caretta caretta) from Baja California Sur, Mexico

    International Nuclear Information System (INIS)

    Highlights: → We report baseline levels of selected heavy metals in blood of Pacific loggerhead turtles. → Blood was used to measure in a relatively non-invasive way baseline values of heavy metals. → Zn and Cd were found in high concentrations compared to levels reported in other parts of the world. → Cu concentrations in blood are high as they relate to concentrations in muscle. → No correlations were found between of heavy metals and metalloids analyzed and the size of the turtles. - Abstract: Environmental pollution due to heavy metals is having an increased impact on marine wildlife accentuated by anthropogenic changes in the planet including overfishing, agricultural runoff and marine emerging infectious diseases. Sea turtles are considered sentinels of ecological health in marine ecosystems. The objective of this study was to determine baseline concentrations of zinc, cadmium, copper, nickel, selenium, manganese, mercury and lead in blood of 22 clinically healthy, loggerhead turtles (Caretta caretta), captured for several reasons in Puerto Lopez Mateos, Baja California Sur, Mexico. Zinc was the most prevalent metal in blood (41.89 μg g-1), followed by Selenium (10.92 μg g-1). The mean concentration of toxic metal Cadmium was 6.12 μg g-1 and 1.01 μg g-1 respectively. Mean concentrations of metals followed this pattern: Zn > Se > Ni > Cu > Mn > Cd > Pb and Hg. We can conclude that blood is an excellent tissue to measure in relatively non-invasive way baseline values of heavy metals in Caretta caretta.

  14. The effect of food with different glycaemic index on the blood glucose level

    Directory of Open Access Journals (Sweden)

    Lenka Kouřimská

    2015-08-01

    Full Text Available Blood glucose levels are affected by many factors including the type of foods consumed, processing technology and cooking method. Hormone insulin lowers blood glucose to its constant level, while glucagon, growth hormone, adrenalin and glucocorticoids have the opposite effect. High steepness of the blood glucose level rise after meals may be unfavourable for the organism. Sugars are transferred into the blood at different speeds according to the type of food. Therefore the aim of this study was to confirm experimentally the effect of food on blood glucose levels in men and women of different ages. Two types of low, medium and high-glycaemic index (GI foods were given to 4 men and 4 women of different age (from 35 to 65 years. All volunteers were healthy, slightly overweight, and without any regular sporting activity. None of them had any idea about their daily carbohydrates consumption and what the term glycaemic index meant. The volunteers came to the GI determination fasted in the morning. Their rise in blood glucose level was monitored by glucometer before the meal and after 1 and 2 hours of the consumption of baked potatoes (GI 85, white bread bun (GI 70, boiled potatoes (GI 64, rye bread (GI 62, potato dumplings (GI 52 and white cooked spaghetti (GI 41. Fasting blood sugar levels of volunteers highly depended on their age (p <0.0001 and gender (p <0.0001. The blood glucose values increased with age and were higher in men than in women. Significant influence of food GI on blood glucose levels in both men and women in all the age categories was observed (p <0.0001. An interaction between age and gender was also statistically highly significant (p <0.0001. One hour after consuming food the blood glucose values were significantly different from the values of fasting (p = 0.0035. The differences of these values did not depend on the age (p = 0.0574 and sex (p = 0.8256 of volunteers, but there was a significant difference on the GI value of food

  15. PREANALITIC AND INTERPRETATION BLOOD GLUCOSE FOR DIAGNOSE DIABETIC MELITUS

    Directory of Open Access Journals (Sweden)

    Ida Bagus Wayan Kardika

    2013-10-01

    Full Text Available Normal 0 false false false EN-US X-NONE X-NONE Diabetes mellitus (DM is a metabolic disorder disease which has been characterised by chronic hyperglycemia as well as abnormalities in the metabolism of carbohydrates, fats and proteins caused by abnormalities of insulin secretion, insulin resistance or both. The Diagnoses of diabetes mellitus in addition based on the clinical aspects of which include anamnesis, physical examination and diagnoses is required in the form of investigations the laboratory examination. The simplest laboratory examination is the examination of blood sugar. The stages of preanalitic and the interpretation of results examination of the blood sugar is worth noting in order to obtain meaningful results so that a diagnosis of diabetes mellitus can be enforced and for monitoring treatment outcomes. /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;}

  16. Baseline Systolic Blood Pressure Response to Exercise Stress Test Can Predict Exercise Indices following Cardiac Rehabilitation Program

    Directory of Open Access Journals (Sweden)

    Akram Sardari

    2010-11-01

    Full Text Available Background: Systolic blood pressure recovery (rSBP is of prognostic value for predicting the survival and co-morbidity rate in patients with coronary artery disease (CAD. This study investigated the association between rSBP and exercise indices after complete cardiac rehabilitation program (CR in a population-based sample of patients undergoing coronary artery bypass grafting (CABG.Methods: The sample population consisted of 352 patients who underwent pure CABG. The patients underwent standard symptom-limited exercise testing immediately before and also after the completion of the CR sessions. rSBP was defined as the ratio of the systolic blood pressure at 3 minutes in recovery to the systolic blood pressure at peak exercise.Results: An abnormal baseline rSBP after exercise was a strong predictor of exercise parameters in the last session, including metabolic equivalents (β = -0.617, SE = 0.127, p value < 0.001 and peak O2 consumption (β = -1.950, SE = 0.363, p value < 0.001 measured in the last session adjusted for baseline exercise characteristics, demographics, function class, and left ventricular ejection fraction.Conclusion: The current study strongly emphasizes the predictive role of baseline rSBP after exercise in evaluating exercise parameters following CR. This baseline index can predict abnormal METs value, peak O2 consumption, post-exercise heart rate, and heart rate recovery after a 24-session CR program.

  17. Blood concentrations of lactate, glucose and corticosterone in dispersing hatchling sea turtles

    Directory of Open Access Journals (Sweden)

    Carla M. Pereira

    2012-11-01

    Natal dispersal of sea turtles is an energetically demanding activity that is fuelled primarily by aerobic metabolism. However, during intense exercise reptiles can use anaerobic metabolism to supplement their energy requirements. We assessed anaerobic metabolism in dispersing hatchling loggerhead and flatback turtles by measuring the concentrations of blood lactate during crawling and at different times during the first four hours of their frenzy swim. We also measured concentrations of blood glucose and corticosterone. Blood lactate (12.13 to 2.03 mmol/L, glucose (6.25 to 3.8 mmol/L and corticosterone (8.13 to 2.01 ng/mL concentrations decreased significantly over time in both loggerhead and flatback hatchlings and no significant differences were found between the species. These results indicate that anaerobic metabolism makes a significant contribution to the dispersal phase of hatchling sea turtles during the beach crawl and the first few hours of the frenzy swim.

  18. A signal processing application for evaluating self-monitoring blood glucose strategies in a software agent model.

    Science.gov (United States)

    Wang, Zhanle; Paranjape, Raman

    2015-07-01

    We propose the signal processing technique of calculating a cross-correlation function and an average deviation between the continuous blood glucose and the interpolation of limited blood glucose samples to evaluate blood glucose monitoring frequency in a self-aware patient software agent model. The diabetic patient software agent model [1] is a 24-h circadian, self-aware, stochastic model of a diabetic patient's blood glucose levels in a software agent environment. The purpose of this work is to apply a signal processing technique to assist patients and physicians in understanding the extent of a patient's illness using a limited number of blood glucose samples. A second purpose of this work is to determine an appropriate blood glucose monitoring frequency in order to have a minimum number of samples taken that still provide a good understanding of the patient's blood glucose levels. For society in general, the monitoring cost of diabetes is an extremely important issue, and these costs can vary tremendously depending on monitoring approaches and monitoring frequencies. Due to the cost and discomfort associated with blood glucose monitoring, today, patients expect monitoring frequencies specific to their health profile. The proposed method quantitatively assesses various monitoring protocols (from 6 times per day to 1 time per week) in nine predefined categories of patient agents in terms of risk factors of health status and age. Simulation results show that sampling 6 times per day is excessive, and not necessary for understanding the dynamics of the continuous signal in the experiments. In addition, patient agents in certain conditions only need to sample their blood glucose 1 time per week to have a good understanding of the characteristics of their blood glucose. Finally, an evaluation scenario is developed to visualize this concept, in which appropriate monitoring frequencies are shown based on the particular conditions of patient agents. This base line can

  19. Glucose tolerance, blood lipid, insulin and glucagon concentration after single or continuous administration of aspartame in diabetics.

    Science.gov (United States)

    Okuno, G; Kawakami, F; Tako, H; Kashihara, T; Shibamoto, S; Yamazaki, T; Yamamoto, K; Saeki, M

    1986-04-01

    A nutritive sweetener, aspartame (L-aspartyl-L-phenylalanine methylester) was administered orally to normal controls and diabetic patients in order to evaluate effects on blood glucose, lipids and pancreatic hormone secretion. An oral glucose tolerance test was also performed in the same subjects as a control study of aspartame administration. In 7 normal controls and 22 untreated diabetics, a single dose of 500 mg aspartame, equivalent to 100 g glucose in sweetness, induced no increase in blood glucose concentration. Rather, a small but significant decrease in blood glucose was noticed 2 or 3 h after administration. The decrease in blood glucose was found to be smallest in the control and became greater as the diabetes increased in severity. No significant change in blood insulin or glucagon concentration during a 3-h period was observed in either the controls or the diabetics. The second study was designed to determine the effects of 2 weeks' continuous administration of 125 mg aspartame, equal in sweetness to the mean daily consumption of sugar (20-30 g) in Japan, to 9 hospitalized diabetics with steady-state glycemic control. The glucose tolerance showed no significant change after 2 weeks' administration. Fasting, 1 h and 2 h postprandial blood glucose, blood cholesterol, triglyceride and HDL-cholesterol were also unaffected. From these and other published results, aspartame would seem to be a useful alternative nutrient sweetener for patients with diabetes mellitus. PMID:3522147

  20. Monitoring of glucose, salt and pure water in human whole blood: An in vitro study.

    Science.gov (United States)

    Imran, Muhammad; Ullah, Hafeez; Akhtar, Munir; Sial, Muhammad Aslam; Ahmed, Ejaz; Durr-E-Sabeeh; Ahmad, Mukhtar; Hussain, Fayyaz

    2016-07-01

    Designing and implementation of non-invasive methods for glucose monitoring in blood is main focus of biomedical scientists to provide a relief from skin puncturing of diabete patient. The objective of this research work is to investigate the shape deformations and the aggregation of red blood cells (RBCs) in the human blood after addition of three different analytes i) (0mM-400mM: Range) of glucose (C(6)H(12)O(6)), ii) (0mM-400mM: range) of pure salt (NaCl) and iii) (0mM- 350mM: range) of pure water (H(2)O). We have observed that the changes in the shape of individual cells from biconcave discs to spherical shapes and eventually the lysis of the cells at optimum concentration of glucose, salts and pure water. This demonstration also provides a base line to facilitate diabetes during partial diagnosis and monitoring of the glucose levels qualitatively both in research laboratories and clinical environment. PMID:27393437

  1. Blood glucose lowering effect of ophiopogonis tuber extract and mechanism of anti-insulin-resistance

    Directory of Open Access Journals (Sweden)

    Meng NING

    2013-01-01

    Full Text Available Objective  To study the hypoglycemic effect and insulin sensitization mechanism of ophiopogonis tuber extracts on the 3T3-L1-induced adipocytes, and also in rats with reproduction of type 2 diabetes mellitus (T2DM. Methods  3T3-L1 cells were induced and differentiated into adipocytes. After the intervention with ophiopogonpolysaccharide (OPSR and ophiopogonin (OPG, glucose consuming rate was detected for screening the extracts which may have effective hypoglycemic effects. The insulin resistance (IR adipocyte model was established by dexamethasone induction, and then it was treated with OPSR. The protein expression levels of leptin, adiponectin and resistin were detected by Western blotting. The T2DM rat model was reproduced and then treated with OPSR for 4 weeks. Body weight (BW, triglyeride (TG, fasting blood glucose (FBG and fasting insulin (FINs of the rats were measured respectively. Results  OPSR in dosage of 0.5-50mg/L promoted glucose consumption of adipocytes in a dose-dependent manner, the glucose consumption ratios were 32.27%, 75.14% and 90.47% respectively. OPG of 50mg/L showed very weak activity with glucose consumption ratio of only 8.49%. OPSR could significantly promote the protein expression of leptin and adiponectin, and showed an inhibitory effect on the protein expression of resistin (P<0.05. After treatment with OPSR for 4 weeks, the BW of rats increased obviously, while TG, FBG and HOMA-IR decreased significantly (P<0.05 or P<0.01. Conclusions  OPSR may promote glucose transport and utilization of adipocytes, decrease the level of FBG and TG, and improve the condition of IR in T2DM rats. The mechanism of blood glucose lowering effect may be attributed to secretion of adipokines, such as leptin, adiponectin and resistin by IR adipocytes.

  2. Determination of Blood Glucose Concentration by Using Wavelet Transform and Neural Networks

    Directory of Open Access Journals (Sweden)

    Vajravelu Ashok

    2013-03-01

    Full Text Available Background: Early and non-invasive determination of blood glucose level is of great importance. We aimed to present a new technique to accurately infer the blood glucose concentration in peripheral blood flow using non-invasive optical monitoring system.Methods: The data for the research were obtained from 900 individuals. Of them, 750 people had diabetes mellitus (DM. The system was designed using a helium neon laser source of 632.8 nm wavelength with 5mW power, photo detectors and digital storage oscilloscope. The laser beam was directed through a single optical fiber to the index finger and the scattered beams were collected by the photo detectors placed circumferentially to the transmitting fiber. The received signals were filtered using band pass filter and finally sent to a digital storage oscilloscope. These signals were then decomposed into approximation and detail coefficients using modified Haar Wavelet Transform. Back propagation neural and radial basis functions were employed for the prediction of blood glucose concentration.Results: The data of 450 patients were randomly used for training, 225 for testing and the rest for validation. The data showed that outputs from radial basis function were nearer to the clinical value. Significant variations could be seen from signals obtained from patients with DM and those without DM.Conclusion: The proposed non-invasive optical glucose monitoring system is able to predict the glucose concentration by proving that there is a definite variation in hematological distribution between patients with DM and those without DM.

  3. Effect of guar crispbread with cereal products and leguminous seeds on blood glucose concentrations of diabetics.

    OpenAIRE

    Jenkins, D J; Wolever, T M; Taylor, R H; Barker, H M; Fielden, H; Jenkins, A. L.

    1980-01-01

    To compare the effect on blood glucose concentrations of guar incorporated into crispbreads with that of unprocessed high-fibre foods groups of four to six diabetics took a total of seven test breakfasts on separate days. By comparison with a breakfast of wholemeal bread and cheese, guar crispbread combined with bread reduced the area under the glucose response curve to 51% (p < 0.05); bread and soya beans reduced the area to 65% (p < 0.05); guar crispbread with soya beans to 25% (p < 0.002);...

  4. Fluorescent blood glucose monitor by hemin-functionalized graphene quantum dots based sensing system

    Energy Technology Data Exchange (ETDEWEB)

    He, Yuezhen; Wang, Xiaoxun; Sun, Jian; Jiao, Shoufeng; Chen, Hongqi; Gao, Feng; Wang, Lun, E-mail: wanglun@mail.ahnu.edu.cn

    2014-01-31

    Graphical abstract: -- Highlights: •Hemin is assembled onto the surfaces of graphene quantum dots (GQDs). •With the aid of hemin, H{sub 2}O{sub 2} could quench the FL signal of GQDs obviously. •Based on this effect, a fluorescent platform is proposed for the sensing of glucose. •The proposed method provides a new pathway to explore practical application of GQDs. -- Abstract: In the present work, a highly sensitive and specific fluorescent biosensor for blood glucose monitoring is developed based on hemin-functionalized graphene quantum dots (GQDs) and glucose oxidase (GOx) system. The GQDs which are simply prepared by pyrolyzing citric acid exhibit strong fluorescence and good water-solubility. Due to the noncovalent assembly between hemin and GQDs, the addition of hemin can make hydrogen peroxide (H{sub 2}O{sub 2}) to destroy the passivated surface of GQDs, leading to significant fluorescence quenching of GQDs. Based on this effect, a novel fluorescent platform is proposed for the sensing of glucose. Under the optimized conditions, the linear range of glucose is from 9 to 300 μM, and the limit of detection is 0.1 μM. As unique properties of GQDs, the proposed biosensor is green, simple, cost-efficient, and it is successfully applied to the determination of glucose in human serum. In addition, the proposed method provides a new pathway to further design the biosensors based on the assembly of GQDs with hemin for detection of biomolecules.

  5. Clinical significance of determination of serum leptin, insulin levels and blood sugar in pregnant women with glucose metabolism disturbances

    International Nuclear Information System (INIS)

    Objective: To investigate the changes of serum leptin, insulin levels and blood sugar contents in pregnant women with gestational glucose metabolism disturbances. Methods: Fasting and 3h after oral 50g glucose serum levels of leptin were measured with RIA in 36 pregnant women with glucose metabolism disturbances (gestational diabetes mellitus or gestational impaired glucose tolerance) and 34 controls. Also, fasting serum insulin levels (with CLIA) and blood sugar contents 1h after oral 50 glucose (with glucose oxidase method) were determined in all these subjects. Results: 1. Serum levels of leptin in pregnant women with glucose metabolism disturbances were 14.9 ± 4.3 μg/L (vs controls 9.8 ± 1.7 μg/L, P<0.01). 2. The serum levels of insulin and 1 h post - 50g glucose blood sugar contents in pregnant women with glucose metabolism disturbances were 12.9±4.3mU/L and 11.0±1.4mmol/L respectively, which were both significantly positively correlated with the serum leptin levels (r=0.835, r=0.758 respectively) (vs levels in controls: 8.45±3.0mU/L and 7.84±1.3mmol/L). Conclusion: Elevation of fasting serum levels of leptin was demonstrated in pregnant women with glucose metabolism disturbances and the level of leptin was positively correlated with that of insulin and blood sugar. (authors)

  6. Study of the Effect of Garlic on Serum Lipids and Blood Glucose Levels in Type 2 Diabetic Patients

    OpenAIRE

    M Afkhami - Ardekani; AR Kamali - Ardakani

    2005-01-01

    Introduction: Hyperlipidemia and diabetes are common risk factors for ischemic heart disease, which is the main cause of mortality in diabetic patients. Strict control of blood glucose and other risk factors in diabetics has led to prevention of complications. Garlic has received particular attention for control of blood glucose and decrease in blood lipid levels. At present, several studies have been carried out in order to prove advantages of garlic. Methods: In this study, effects of garsi...

  7. Performance Evaluation and Labeling Comprehension of a New Blood Glucose Monitoring System with Integrated Information Management

    Science.gov (United States)

    List, Susan M; Starks, Nykole; Baum, John; Greene, Carmine; Pardo, Scott; Parkes, Joan L; Schachner, Holly C; Cuddihy, Robert

    2011-01-01

    Background This study evaluated performance and product labeling of CONTOUR® USB, a new blood glucose monitoring system (BGMS) with integrated diabetes management software and a universal serial bus (USB) port, in the hands of untrained lay users and health care professionals (HCPs). Method Subjects and HCPs tested subject's finger stick capillary blood in parallel using CONTOUR USB meters; deep finger stick blood was tested on a Yellow Springs Instruments (YSI) glucose analyzer for reference. Duplicate results by both subjects and HCPs were obtained to assess system precision. System accuracy was assessed according to International Organization for Standardization (ISO) 15197:2003 guidelines [within ±15 mg/dl of mean YSI results (samples system features and ease-of-use were evaluated by subject questionnaires. Results All subjects who completed the study (N = 74) successfully performed blood glucose measurements, connected the meter to a laptop computer, and used key features of the system. The system was accurate; 98.6% (146/148) of subject results and 96.6% (143/148) of HCP results exceeded ISO 15197:2003 criteria. All subject and HCP results were clinically accurate (97.3%; zone A) or associated with benign errors (2.7%; zone B). The majority of subjects rated features of the BGMS as “very good” or “excellent.” Conclusions CONTOUR USB exceeded ISO 15197:2003 system performance criteria in the hands of untrained lay users. Subjects understood the product labeling, found the system easy to use, and successfully performed blood glucose testing. PMID:22027308

  8. Molecular Weight Dependent Glucose Lowering Effect of Low Molecular Weight Chitosan Oligosaccharide (GO2KA1 on Postprandial Blood Glucose Level in SD Rats Model

    Directory of Open Access Journals (Sweden)

    Emmanouil Apostolidis

    2013-07-01

    Full Text Available This research investigated the effect of enzymatically digested low molecular weight (MW chitosan oligosaccharide on type 2 diabetes prevention. Three different chitosan oligosaccharide samples with varying MW were evaluated in vitro for inhibition of rat small intestinal α-glucosidase and porcine pancreatic α-amylase (GO2KA1; 10,000 Da. The in vitro results showed that all tested samples had similar rat α-glucosidase inhibitory and porcine α-amylase inhibitory activity. Based on these observations, we decided to further investigate the effect of all three samples at a dose of 0.1 g/kg, on reducing postprandial blood glucose levels in Sprague-Dawley (SD rat model after sucrose loading test. In the animal trial, all tested samples had postprandial blood glucose reduction effect, when compared to control, however GO2KA1 supplementation had the strongest effect. The glucose peak (Cmax for GO2KA1 and control was 152 mg/dL and 193 mg/dL, respectively. The area under the blood glucose-time curve (AUC for GO2KA1 and control was 262 h mg/dL and 305 h mg/dL, respectively. Furthermore, the time of peak plasma concentration of blood glucose (Tmax for GO2KA1 was significantly delayed (0.9 h compared to control (0.5 h. These results suggest that GO2KA1 could have a beneficial effect for blood glucose management relevant to diabetes prevention in normal and pre-diabetic individuals. The suggested mechanism of action is via inhibition of the carbohydrate hydrolysis enzyme α-glucosidase and since GO2KA1 (MW < 1000 Da had higher in vivo effect, we hypothesize that it is more readily absorbed and might exert further biological effect once it is absorbed in the blood stream, relevant to blood glucose management.

  9. Detection accuracy of three glucose meters estimated by capillary blood glucose measurements compared with venous blood evaluated by the diabetes unit of the Hospital Evangélico de Curitiba, Brazil

    Directory of Open Access Journals (Sweden)

    Camacho SL

    2012-05-01

    Full Text Available Mirnaluci Paulino Ribeiro Gama, Camile Fiorese Cruzeta, Ana Carolina Ossowski, Marina Rech Bay, Mariella Muller Michaelis, Stênio Lujan CamachoEndocrinology and Diabetes Service, Hospital Universitário Evangélico de Curitiba, BrazilObjective: To compare capillary blood glucose measurements between three different glucose meters and with the serum glucose values of inpatients at the diabetes unit of Hospital Universitário Evangélico de Curitiba, Brazil.Materials and methods: A total of 132 non-intensive care unit patients admitted for medical and surgical pathologies were evaluated. All patients reported a previous diagnosis of diabetes mellitus, were under 60 years of age, had no hematocrit alterations, remained hemodynamically stable during the time of data collection, and were given no ascorbic acid, acetaminophen, dopamine, or mannitol during follow-up. Capillary and serum blood glucose samples were collected simultaneously by finger-stick and venipuncture 2 hours after lunch, by the same observer, who was blinded to the serum glucose results. First, between July and November 2009, capillary glucose levels were measured using the blood glucose meters OneTouch SureStep® and MediSense Optium®. Between November 2009 and February 2010, capillary blood glucose levels were measured on the glucose meters OneTouch SureStep and Optium Xceed®. The capillary glucose readings were analyzed between meters and also in relation to the serum blood glucose values by the t-test for paired samples and the Mood two-sample test.Results: The patients’ mean age was 50.45 years. The blood glucose means obtained using the meters OneTouch SureStep, MediSense Optium, and Optium Xceed were, respectively, 183.87 mg/dL, 178.49 mg/dL, and 192.73 mg/dL, and the mean for the serum glucose values was 174.58 mg/dL. A significant difference was found between the capillary measurements taken by the glucose meters and the serum glucose measurements (P < 0.05, and no

  10. Overnight Control of Blood Glucose in People with Type 1 Diabetes

    DEFF Research Database (Denmark)

    Boiroux, Dimitri; Duun-Henriksen, Anne Katrine; Schmidt, Signe;

    2012-01-01

    In this paper, we develop and test a Model Predictive Controller (MPC) for overnight stabilization of blood glucose in people with type 1 diabetes. The controller uses glucose measurements from a continuous glucose monitor (CGM) and its decisions are implemented by a continuous subcutaneous insulin...... infusion (CSII) pump. Based on a priori patient information, we propose a systematic method for computation of the model parameters in the MPC. Safety layers improve the controller robustness and reduce the risk of hypoglycemia. The controller is evaluated in silico on a cohort of 100 randomly generated...... patients with a representative intersubject variability. This cohort is simulated overnight with realistic variations in the insulin sensitivities and needs. Finally, we provide results for the first tests of this controller in a real clinic....

  11. Correlation between baseline blood pressure and the brainstem FMRI response to isometric forearm contraction in human volunteers: a pilot study.

    Science.gov (United States)

    Coulson, J M; Murphy, K; Harris, A D; Fjodorova, M; Cockcroft, J R; Wise, R G

    2015-07-01

    It has been shown previously that changes in brainstem neural activity correlate with changes in both mean arterial pressure (MAP) and muscle sympathetic nerve activity (MSNA) during static handgrip (SHG). However, the relationship between baseline MAP and brainstem neural activity is unclear. We investigated changes in blood oxygen level-dependent (BOLD) signal induced by SHG in 12 young adults using BOLD functional magnetic resonance imaging (FMRI). An estimation of the blood pressure response to SHG was obtained in seven subjects during a session outside the MRI scanner and was used to model the blood pressure response to SHG inside the scanner. SHG at 40% of maximum grip increased MAP (mean ± s.d.) at the end of the 180-s squeeze from 85 ± 6 mm Hg to 108 ± 15 mm Hg, P = 0.0001. The brainstem BOLD signal change associated with SHG was localised to the ventrolateral medulla. This regional BOLD signal change negatively correlated with baseline MAP, r = -0.61, P = 0.01. This relationship between baseline MAP and brainstem FMRI responses to forearm contraction is suggestive of a possible role for brainstem activity in the control of MAP and may provide mechanistic insights into neurogenic hypertension. PMID:25391759

  12. Intraoperative blood glucose management: impact of a real-time decision support system on adherence to institutional protocol.

    Science.gov (United States)

    Nair, Bala G; Grunzweig, Katherine; Peterson, Gene N; Horibe, Mayumi; Neradilek, Moni B; Newman, Shu-Fang; Van Norman, Gail; Schwid, Howard A; Hao, Wei; Hirsch, Irl B; Patchen Dellinger, E

    2016-06-01

    Poor perioperative glycemic management can lead to negative surgical outcome. Improved compliance to glucose control protocol could lead to better glucose management. An Anesthesia Information Management System based decision support system-Smart Anesthesia Manager™ (SAM) was used to generate real-time reminders to the anesthesia providers to closely adhere to our institutional glucose management protocol. Compliance to hourly glucose measurements and correct insulin dose adjustments was compared for the baseline period (12 months) without SAM and the intervention period (12 months) with SAM decision support. Additionally, glucose management parameters were compared for the baseline and intervention periods. A total of 1587 cases during baseline and 1997 cases during intervention met the criteria for glucose management (diabetic patients or non-diabetic patients with glucose level >140 mg/dL). Among the intervention cases anesthesia providers chose to use SAM reminders 48.7 % of the time primarily for patients who had diabetes, higher HbA1C or body mass index, while disabling the system for the remaining cases. Compliance to hourly glucose measurement and correct insulin doses increased significantly during the intervention period when compared with the baseline (from 52.6 to 71.2 % and from 13.5 to 24.4 %, respectively). In spite of improved compliance to institutional protocol, the mean glucose levels and other glycemic management parameters did not show significant improvement with SAM reminders. Real-time electronic reminders improved intraoperative compliance to institutional glucose management protocol though glycemic parameters did not improve even when there was greater compliance to the protocol. PMID:26067402

  13. Effects of long duration exercise on cognitive function, blood glucose, and counterregulatory hormones in male cyclists.

    Science.gov (United States)

    Grego, Fabien; Vallier, Jean-Marc; Collardeau, Maya; Bermon, Stéphane; Ferrari, Patricia; Candito, Mirande; Bayer, Pascale; Magnié, Marie-Noëlle; Brisswalter, Jeanick

    2004-07-01

    Electrocortical effects of long duration exercise on cognitive function were investigated by analyzing P300 amplitude and latency changes during a 3-h cycling exercise. P300 components were measured in 12 well-trained cyclists and blood glucose, cortisol, insulin, glycerol, and free fatty acids (FFAs) epinephrine and norepinephrine were analyzed. Results indicated that P300 components were affected by exercise with a temporary increase in amplitude between the 1st and the 2nd hour and an increase in latency after 2 h of exercise concomitant with some hormonal changes, including an increase in cortisol and epinephrine and a decrease in blood glucose. These findings suggest a combined effect of arousal and central fatigue on electrocortical indices of cognitive function during acute physical exercise. PMID:15196681

  14. Frequency and motives of blood glucose self-monitoring in type 1 diabetes

    DEFF Research Database (Denmark)

    Hansen, M V; Pedersen-Bjergaard, U; Heller, S R;

    2009-01-01

    AIMS: Recommendations for self-monitoring of blood glucose (SMBG) from the DCCT have not been implemented with the same rigour as recommendations for intensifying insulin therapy. We assessed the frequency of and motives for SMBG and compared SMBG behaviour with clinical, behavioural and demograp......AIMS: Recommendations for self-monitoring of blood glucose (SMBG) from the DCCT have not been implemented with the same rigour as recommendations for intensifying insulin therapy. We assessed the frequency of and motives for SMBG and compared SMBG behaviour with clinical, behavioural and...... hypoglycaemia and awareness of hypoglycaemia were independently associated with testing behaviour, whereas the presence of late diabetic complications was not. Lower HbA1c was associated with more frequent testing. CONCLUSION: Patient compliance regarding SMBG is limited. Thus, almost two thirds of the patients...

  15. Scale Space Methods for Analysis of Type 2 Diabetes Patients' Blood Glucose Values

    Directory of Open Access Journals (Sweden)

    Stein Olav Skrøvseth

    2011-01-01

    Full Text Available We describe how scale space methods can be used for quantitative analysis of blood glucose concentrations from type 2 diabetes patients. Blood glucose values were recorded voluntarily by the patients over one full year as part of a self-management process, where the time and frequency of the recordings are decided by the patients. This makes a unique dataset in its extent, though with a large variation in reliability of the recordings. Scale space and frequency space techniques are suited to reveal important features of unevenly sampled data, and useful for identifying medically relevant features for use both by patients as part of their self-management process, and provide useful information for physicians.

  16. Scale space methods for analysis of type 2 diabetes patients' blood glucose values.

    Science.gov (United States)

    Skrøvseth, Stein Olav; Godtliebsen, Fred

    2011-01-01

    We describe how scale space methods can be used for quantitative analysis of blood glucose concentrations from type 2 diabetes patients. Blood glucose values were recorded voluntarily by the patients over one full year as part of a self-management process, where the time and frequency of the recordings are decided by the patients. This makes a unique dataset in its extent, though with a large variation in reliability of the recordings. Scale space and frequency space techniques are suited to reveal important features of unevenly sampled data, and useful for identifying medically relevant features for use both by patients as part of their self-management process, and provide useful information for physicians. PMID:21436873

  17. Semiquantitative imaging measurement of baseline and vasomodulated normal prostatic blood flow using sildenafil

    OpenAIRE

    Haaga, JR; Exner, A; Fei, B; Seftel, AD

    2006-01-01

    The physiologic variability of blood flow to the prostate has not been studied until this time. We report the vasoactive effects of sildenafil and phenylephrine on blood flow of the normal prostate. Sildenafil increases prostate blood flow by approximately 75% and phenylephrine reduces the flow incrementally. Administration of these drugs with dynamic contrast-enhanced magnetic resonance imaging may improve the diagnosis of cancerous tissue because according to the literature, tumor angiogeni...

  18. Blood Flow and Glucose Metabolism in Stage IV Breast Cancer: Heterogeneity of Response During Chemotherapy

    OpenAIRE

    Krak, Nanda; Hoeven, John; Hoekstra, Otto; Twisk, Jos; Wall, Ernst; Lammertsma, A. A.

    2008-01-01

    textabstractObjective: The purpose of the study was to compare early changes in blood flow (BF) and glucose metabolism (MRglu) in metastatic breast cancer lesions of patients treated with chemotherapy. Methods: Eleven women with stage IV cancer and lesions in breast, lymph nodes, liver, and bone were scanned before treatment and after the first course of chemotherapy. BF, distribution volume of water (Vd), MRglu/BF ratio, MRgluand its corresponding rate constants K1and k3were compared per tum...

  19. Poorly Regulated Blood Glucose in Diabetic Patients–predictor of Acute Infections

    OpenAIRE

    Burekovic, Azra; Dizdarevic–Bostandzic, Amela; Godinjak, Amina

    2014-01-01

    Introduction: Diabetes mellitus, the most frequent endocrinology disease is a predisposing factor for infections. Diabetic patients have 4,4 times greater risk of systemic infection than non diabetics. Aim: a) To determine the prevalence and characteristics of acute infectious diseases in hospitalized diabetics; b) To correlate values of blood glucose levels and HbA1c with acute infections in hospitalized diabetics; c) To identify the etiology of infectious diseases. Material and methods: The...

  20. Non-invasive detection of fasting blood glucose level via electrochemical measurement of saliva

    OpenAIRE

    Malik, Sarul; Khadgawat, Rajesh; Anand, Sneh; Gupta, Shalini

    2016-01-01

    Machine learning techniques such as logistic regression (LR), support vector machine (SVM) and artificial neural network (ANN) were used to detect fasting blood glucose levels (FBGL) in a mixed population of healthy and diseased individuals in an Indian population. The occurrence of elevated FBGL was estimated in a non-invasive manner from the status of an individual’s salivary electrochemical parameters such as pH, redox potential, conductivity and concentration of sodium, potassium and calc...

  1. Effect of Different Isoenergetic Breakfast Compositions on Blood Glucose Regulation, Energy Allocation and Satiety

    Directory of Open Access Journals (Sweden)

    Aloys Berg

    2014-08-01

    Full Text Available "Background and purpose: The increasing prevalence of overweight and obesity among adults, demands improved dietary strategies for weight management and metabolic competence. Hence, the objective of this study was to assess the short-term effects of breakfasts with varying macronutrient composition on blood glucose regulation, energy metabolism and satiety. Methods: This study examined ten healthy males (25.6 ± 4.4 yrs; BMI 23.2 ± 0.9 kg/m2 fed isoenergetic breakfasts rich in either Carbohydrate [CH] (68% of energy, Fat [Fat] (64% of energy or Protein [P] (35% of energy or a breakfast which reflected the individuals Normal [N] breakfast composition. Blood glucose and lactate, resting oxygen consumption (VO2, Respiratory Quotient (RQ and satiety feeling were measured. All breakfasts with the exception of the individual normal breakfast variant were isoenergetic and all contained the same amount of dietary fiber. As a non-dietary control, subjects drank 200 ml water on one test day, with the same metabolic parameters measured. Results: Compared with the water control day, there was a significant macronutrient-induced change in the metabolic parameters. The most significant increases in blood glucose were found after the Carbohydrate breakfast and the individual normal breakfast, whereas the Fat and Protein-rich breakfasts induced comparatively smaller blood glucose responses. Only the Proteinrich breakfast led to significant increases in resting VO2 (up to 30% without changes in RQ. Finally, the Protein-rich breakfast induced the highest satiety feeling. Conclusions: Although the Protein-induced effects may initially appear minor, the combination of a reduced glycemic response, increased VO2, a proportionately high fat oxidation and a stronger satiety effect may support the use of this dietary approach for healthy weight management in normal weight men."

  2. Effects of Yogic Exercises on Life Stress and Blood Glucose Levels in Nursing Students

    OpenAIRE

    Kim, Sang Dol

    2014-01-01

    [Purpose] This study was performed to investigate the effects of yogic exercises on life stress and blood glucose levels in nursing students. [Subjects and Methods] The study was a randomized controlled trial. Twenty-seven undergraduate nursing students were randomly selected, with 12 assigned to an exercise group and 15 assigned to a control group. The yogic exercises intervention was undertaken for 60 minutes one day a week for 12 weeks. It consisted of physical exercise (surya namaskara) c...

  3. Diabetes Automata For Diabetes-Related Applications: Software Engine For Blood Glucose Level Simulation

    OpenAIRE

    Agafonov, Aleksandr

    2015-01-01

    Diabetes Automata is a try of concept in the complex research-field of blood glucose simulation and prediction in experimental medical informatics, an experimental research project in software engineering combined with experimental health science. The project integrates together topics such as software system design and development, object-oriented programming, mobile application development, experimental health informatics and electronic health in general and mobile health in particular, and...

  4. Impact of admission blood glucose level on outcomes in community-acquired pneumonia in older adults

    OpenAIRE

    Bhattacharya RK; Mahnken JD; Rigler SK

    2013-01-01

    Rajib K Bhattacharya, Jonathan D Mahnken, Sally K RiglerUniversity of Kansas School of Medicine, Kansas City, KS, USABackground: Community-acquired pneumonia (CAP) is a common cause of morbidity and mortality in older adults. Although diabetes mellitus is a risk factor for pneumonia, the clinical impact of blood glucose level at the time of admission is not clear. Our goal was to examine the association between admission hyperglycemia and subsequent mortality, length of stay, and readmission ...

  5. Blood glucose may be an alternative to cholesterol in CVD risk prediction charts

    OpenAIRE

    Braun, Julia; Bopp, Matthias; Faeh, David

    2013-01-01

    Background Established risk models for the prediction of cardiovascular disease (CVD) include blood pressure, smoking and cholesterol parameters. The use of total cholesterol for CVD risk prediction has been questioned, particularly for primary prevention. We evaluated whether glucose could be used instead of total cholesterol for prediction of fatal CVD using data with long follow-up. Methods We followed-up 6,095 men and women aged ≥16 years who participated 1977-79 in a community based heal...

  6. Do Currently Available Blood Glucose Monitors Meet Regulatory Standards? 1-Day Public Meeting in Arlington, Virginia

    OpenAIRE

    Klonoff, David C.; Reyes, Juliet S.

    2013-01-01

    Blood glucose monitors (BGMs) are approved by regulatory agencies based on their performance during strict testing conducted by their manufacturers. However, after approval, there is uncertainty whether BGMs maintain the accuracy levels that were achieved in the initial data. The availability of inaccurate BGM systems pose a public health problem because their readings serve as a basis for treatment decisions that can be incorrect. Several articles have concluded that BGMs in the marketplace ...

  7. Aging, Vascular Risk and Cognition: Blood Glucose, Pulse Pressure, and Cognitive Performance in Healthy Adults

    OpenAIRE

    Dahle, Cheryl L.; Jacobs, Bradley S.; Raz, Naftali

    2009-01-01

    Advanced age is associated with decline in many areas of cognition as well as increased frequency of vascular disease. Well-described risk factors for vascular disease such as diabetes and arterial hypertension have been linked to cognitive deficits beyond those associated with aging. To examine whether vascular health indices such as fasting blood glucose levels and arterial pulse pressure can predict subtle deficits in age-sensitive abilities, we studied 104 healthy adults (age 18 to 78 yea...

  8. What is the optimal blood glucose target in critically ill patients? A nested cohort study

    OpenAIRE

    Ashraf Al-Tarifi; Nabil Abou-Shala; Tamim, Hani M; Rishu, Asgar H.; Yaseen M. Arabi

    2011-01-01

    Aims: There is an uncertainty about what constitutes an optimal level of blood glucose (BG) in critically ill patients. The objective of this study is to identify the optimal BG target for glycemic control in critically ill patients that is associated with survival benefit with the least hypoglycemia risk. Setting and Design: This is a nested cohort study within a randomized control trial conducted in a tertiary care center in King Abdulaziz Medical City, Riyadh, Kingdom of Saudi Arabia. ...

  9. Dioscorea alata L. Reduces Body Weight by Reducing Food Intake and Fasting Blood Glucose Level

    OpenAIRE

    Helen, Olubobokun Titilope; Olusola, Aluko Esther; Eghosa E, Iyare; Bond, Anyaehie Ugochukwu

    2013-01-01

    Aims: The prevalence of type 2 diabetes may be most likely linked to obesity and its prevalence appears to have increased as the prevalence of obesity increased. Dioscorea alata L. has been observed to possess flavonoids which induce antidiabetic effect and phenolic compounds which could help in weight management. It has been postulated that any therapeutic regimes that can limit weight gain while simultaneously controlling blood glucose levels will be effective in managing diabetes. This stu...

  10. Low perfusion index affects the difference in glucose level between capillary and venous blood

    OpenAIRE

    Acar N; Ozcelik H; Cevik AA; Ozakin E; Yorulmaz G; Kebapci N; Bilge U; Bilgin M

    2014-01-01

    Nurdan Acar,1 Hamit Ozcelik,1 Arif Alper Cevik,1 Engin Ozakin,1 Goknur Yorulmaz,2 Nur Kebapci,2 Ugur Bilge,3 Muzaffer Bilgin4 1Emergency Department, 2Endocrinology Department, 3Family Medicine Department, 4Biostatistics Department, Medical School, Eskisehir Osmangazi University, Eskisehir, Turkey Aim: In emergency cases, finger stick testing is primarily used to check the blood glucose value of patients since it takes longer to obtain the venous value. In critical patients, under conditions ...

  11. Diabetes screening and the distribution of blood glucose levels in rural areas of North India

    OpenAIRE

    Tomi Thomas; Shalini Prabhata; Sameer Valsangkar

    2015-01-01

    Background and Objectives: Genetics and environment have both been implicated in the exponential rise in the prevalence of diabetes mellitus that affects 65.1 million people, and leads to a mortality of 1 million people every year in India. This study was devised to obtain the trends of the distribution of blood glucose, and sociodemographic characteristics in rural areas of a North Indian state. Materials and Methods: A cross-sectional study was conducted at eight centers in five districts. ...

  12. Blood glucose regulation in diabetics. A flatness based nonlinear control simulation study

    Science.gov (United States)

    Cocha, Guillermo; Podestá, Melina; Mazzadi, Alejandro; Amorena, Carlos; D’Atellis, Carlos

    2016-04-01

    Flat systems are a generalization of linear systems, but the techniques used for controlling flat systems are much different than many of the existing techniques for linear systems. In this paper we present the flatness-based control of blood glucose regulation in human system. A non-near model, he Bergman Minimal Model, is used o represent he dynamics of blood regulation in humans and because of the flatness property, he system variables can be expressed as functions of he at output and heir time derivatives and a control aw developed.

  13. Effects of breakfast with different calorigenic amounts on blood glucose, insulin and glucagon levels

    Institute of Scientific and Technical Information of China (English)

    HUANG Su-xia(黄素霞); FU Yun-xing(傅运兴); WANG Hui-ming(王慧铭); GIANG Sylvia

    2003-01-01

    This study was aimed to investigate the relationship between breakfast and serum glucose, insulin and glucagon concentrations in order to establish a model breakfast appropriate for Chinese. Twenty-four volunteers were randomly assigned to four study groups: high carbohydrate breakfast, high fat and protein breakfast, the typical breakfast and fasting. Each subject had serum and urine samples collected while fasting and at 1,2 and 3.5 hours following the meal. The concentration of serum glucose, insulin and glucagon was measured. The levels of serum glucose in group A,B and C differed significantly at 1 and 2 hour after meal compared to those at fasting (P<0.05). The serum glucose in group A increased insignificantly after meal. The serum insulin levels were in group A,B and C significant different compared with control group(P<0.05).Those peaked at 1 hour after meal ,with group C rising the furthest. Compared with the fasting group, the serum glucagons rose and maintained the increase after breakfast in group A,B and C (P<0.05).The data suggested that various diets with different calorigenic amounts increased hormone concentration to various extents. We found that a breakfast rich in carbohydrates could maintain proper blood glucose level.

  14. Effects of breakfast with different calorigenic amounts on blood glucose, insulin and glucagon levels

    Institute of Scientific and Technical Information of China (English)

    黄素霞; 傅运兴; 王慧铭; GIANGSylvia

    2003-01-01

    This study was aimed to investigate the relationship between breakfast and serum glucose, insulin and glueagon concentrations in order to establish a model breakfast appropriate for Chinese. Twenty-four vol-unteers were randomly assigned to four study groups: high carbohydrate breakfast, high fat and protein break-fast, the typical breakfast and fasting. Each subject had serum and urine samples collected while fasting andat 1,2 and 3.5 hours following the meal. The concentration of serum glucose, insulin and glucagon was mea-sured. The levels of serum glucose in group A, B and C differed significantly at 1 and 2 hour after meal com-pared to those at fasting ( P < 0.05) . The serum glucose in group A increased insignificantly after meal. The serum insulin levels were in group A, B and C significant different compared with control group( P < 0.05) .Those peaked at 1 hour after meal ,with group C rising the furthest. Compared with the fasting group, the se-rum glueagons rose and maintained the increase after breakfast in group A, B and C (P < 0.05).The data suggested that various diets with different ealorigenie amounts increased hormone concentration to various extents. We found that a breakfast rich in carbohydrates could maintain proper blood glucose level.

  15. Alcohol decreases baseline brain glucose metabolism more in heavy drinkers than controls but has no effect on stimulation-induced metabolic increases

    International Nuclear Information System (INIS)

    During alcohol intoxication the human brain increases metabolism of acetate and decreases metabolism of glucose as energy substrate. Here we hypothesized that chronic heavy drinking facilitates this energy substrate shift both for baseline and stimulation conditions. To test this hypothesis we compared the effects of alcohol intoxication (0.75g/kg alcohol versus placebo) on brain glucose metabolism during video-stimulation (VS) versus when given with no-stimulation (NS), in 25 heavy drinkers (HD) and 23 healthy controls each of whom underwent four PET-18FDG scans. We showed that resting whole-brain glucose metabolism (placebo-NS) was lower in HD than controls (13%, p=0.04); that alcohol (compared to placebo) decreased metabolism more in HD (20±13%) than controls (9±11%, p=0.005) and in proportion to daily alcohol consumption (r=0.36, p=0.01) but found that alcohol did not reduce the metabolic increases in visual cortex from VS in either group. Instead, VS reduced alcohol-induced decreases in whole-brain glucose metabolism (10±12%) compared to NS in both groups (15±13%, p=0.04), consistent with stimulation-related glucose metabolism enhancement. These findings corroborate our hypothesis that heavy alcohol consumption facilitates use of alternative energy substrates (i.e. acetate) for resting activity during intoxication, which might persist through early sobriety, but indicate that glucose is still favored as energy substrate during brain stimulation. Our findings are consistent with reduced reliance on glucose as the main energy substrate for resting brain metabolism during intoxication (presumably shifting to acetate or other ketones) and a priming of this shift in heavy drinkers, which might make them vulnerable to energy deficits during withdrawal

  16. Effects of laser acupoint irradiation on blood glucose and glycosylated hemoglobin in type 2 diabetes mellitus

    Science.gov (United States)

    Hui-Hui, Liu; Guo-Xin, Xiong; Li-Ping, Zhang

    2016-06-01

    To investigate the effects of semiconductor laser acupoint irradiation on blood glucose, glycosylated hemoglobin and physical fitness in type 2 diabetes mellitus, 44 cases of type 2 diabetic patients were randomly divided into a control group and a treatment group. All patients in both groups were given a drug treatment. The Hegu, Quchi and Zusanli acupoints of patients in the treatment group were then irradiated daily for 15 d with a 10 MW semiconductor laser. Before and after treatment, patients in both groups underwent a variety of tests and measurements: a two-hour postprandial blood glucose test; a glycosylated hemoglobin test and body mass index (BMI), waist-to-hip ratio (WHR) and body fat percentage (BFP) measurements. The data detected after treatment greatly decreased in the treatment group and was significantly different from that in the control group. It is shown that the acupoint irradiation with a semiconductor laser can improve two-hour postprandial blood glucose, glycosylated hemoglobin and some physical fitness measurements in type 2 diabetes mellitus patients.

  17. Effect of Iranian Honey bee (Apis Mellifera Venom on Blood Glucose and Insulin in Diabetic Rats

    Directory of Open Access Journals (Sweden)

    Seyyedeh Mahbubeh Mousavi

    2012-12-01

    Full Text Available Background: Diabetes is an important disease. This disease is a metabolic disorder characterized by hyperglycemia resulting from perturbation in insulin secretion, insulin action or both. Honey bee venom contains a wide range of polypeptide agents. The principle components of bee venom are mellitin and phospholipase A2. These components increase insulin secretion from the β-cells of pancreas. This study was conducted to show the hypoglycemic effect of honey bee venom on alloxan induced diabetic male rats.Methods: Eighteen adult male rats weighting 200±20 g were placed into 3 randomly groups: control, alloxan monohy­drate-induced diabetic rat and treated group that received honey bee venom daily before their nutrition for four months. Forty eight hours after the last injection, blood was collected from their heart, serum was dissented and blood glucose, insulin, triglyceride and total cholesterol were determined.Results: Glucose serum, triglyceride and total cholesterol level in treated group in comparison with diabetic group was significantly decreased (P< 0.01. On the other hand, using bee venom causes increase in insulin serum in com­parison with diabetic group (P< 0.05.Conclusion: Honeybee venom (apitoxin can be used as therapeutic option to lower blood glucose and lipids in dia­betic rats.

  18. System Accuracy Evaluation of the GlucoRx Nexus Voice TD-4280 Blood Glucose Monitoring System

    Directory of Open Access Journals (Sweden)

    Muhammad Khan

    2014-01-01

    Full Text Available Use of blood glucose (BG meters in the self-monitoring of blood glucose (SMBG significantly lowers the risk of diabetic complications. With several BG meters now commercially available, the International Organization for Standardization (ISO ensures that each BG meter conforms to a set degree of accuracy. Although adherence to ISO guidelines is a prerequisite for commercialization in Europe, several BG meters claim to meet the ISO guidelines yet fail to do so on internal validation. We conducted a study to determine whether the accuracy of the GlucoRx Nexus TD-4280 meter, utilized by our department for its cost-effectiveness, complied with ISO guidelines. 105 patients requiring laboratory blood glucose analysis were randomly selected and reference measurements were determined by the UniCel DxC 800 clinical system. Overall the BG meter failed to adhere to the ≥95% accuracy criterion required by both the 15197:2003 (overall accuracy 92.4% and 15197:2013 protocol (overall accuracy 86.7%. Inaccurate meters have an inherent risk of over- and/or underestimating the true BG concentration, thereby risking patients to incorrect therapeutic interventions. Our study demonstrates the importance of internally validating the accuracy of BG meters to ensure that its accuracy is accepted by standardized guidelines.

  19. Glucagon-like peptide-1 (GLP-1) raises blood-brain glucose transfer capacity and hexokinase activity in human brain

    DEFF Research Database (Denmark)

    Jensen, Michael Gejl; Lerche, Susanne; Egefjord, Lærke; Brock, Birgitte; Møller, Niels; Vang, Kim; Rodell, Anders B; Bibby, Bo M; Holst, Jens Juul; Rungby, Jørgen; Gjedde, Albert

    2013-01-01

    phosphorylation velocity (V max) in the gray matter regions of cerebral cortex, thalamus, and cerebellum, as well as increased blood-brain glucose transport capacity (T max) in gray matter, white matter, cortex, thalamus, and cerebellum. In hypoglycemia, GLP-1 had no effects on net glucose metabolism, brain......In hyperglycemia, glucagon-like peptide-1 (GLP-1) lowers brain glucose concentration together with increased net blood-brain clearance and brain metabolism, but it is not known whether this effect depends on the prevailing plasma glucose (PG) concentration. In hypoglycemia, glucose depletion...... potentially impairs brain function. Here, we test the hypothesis that GLP-1 exacerbates the effect of hypoglycemia. To test the hypothesis, we determined glucose transport and consumption rates in seven healthy men in a randomized, double-blinded placebo-controlled cross-over experimental design. The acute...

  20. 社区老年人血糖水平与MMSE得分关系%Relation between blood glucose and MMSE score among older people in community

    Institute of Scientific and Technical Information of China (English)

    杨敬源; 黄文湧; 杨星; 汪俊华; 蔡毅媛

    2011-01-01

    Objective To research the effect of different blood glucose level on the score of mini mental state exmination(MMSE) among older people and to provide scientific advice for prevention of cognitive decline in the elderly. Methods Baseline information were collected in 2003 among older people in communities of Guiyang city and the follow-up was conducted in 2008. The relation between different blood glucose level and score of MMSE was analyzed. Results Single factor analysis showed that sex, age, education level were related to MMSE score. At the baseline survey, the MMSE score was 29,28.5, and 28 for people with normal blood glucose, impaired fasting glucose (IFG) and diabetes mitllitus (DM) ,respectively, with significant difference among the three groups. In the follow-up survey, the MMSE score was 27,27 ,and 26 for people with normal blood glucose, IFG, and DM,respectively,with significant differences among the three groups. There was no significant difference in the decrease of MMSE score among the people with different blood glucose during the follow-uP(x2 = 2.28, P < 0. 05 ). Multifactor analysis showed that there was a significant correlation between fasting glucose and baseline MMSE score and the decrease of MMSE score during the follow-up. Conclusion Abnormal blood glucose could lead to the decline of cognition in older people.%目的 探讨不同血糖水平对老年人简单智能量表(mini mental state examination,MMSE)得分影响,为预防老年人认知功能下降提供科学依据.方法 于2003年对贵州省贵阳市老年人空腹血糖及MMSE得分进行调查,2008年进行随访;分析基线、随访时不同血糖水平与MMSE得分的关系,以及不同血糖值与随访期间MMSE得分下降的关系.结果 单因素方差分析结果表明,不同性别、年龄、文化程度、血糖不同水平的MMES得分差异有统计学意义;基线时血糖正常者MMSE得分29,空腹血糖受损(IFG)者为28.5,糖尿病者(DM)为28,3组

  1. Prevalence of glucose-6-phosphate dehydrogenase deficiency and sickle cell trait among blood donors in Riyadh

    Directory of Open Access Journals (Sweden)

    Alabdulaali Mohammed

    2010-01-01

    Full Text Available Background and Aims: Blood donation from glucose-6-phosphate dehydrogenase (G6PD-deficient and sickle cell trait (SCT donors might alter the quality of the donated blood during processing, storage or in the recipient′s circulatory system. The aim of this study was to determine the prevalence of G6PD deficiency and SCT among blood donors coming to King Khalid University Hospital (KKUH in Riyadh. It was also reviewed the benefits and risks of transfusing blood from these blood donors. Materials and Methods: This cross-sectional study was conducted on 1150 blood samples obtained from blood donors that presented to KKUH blood bank during the period April 2006 to May 2006. All samples were tested for Hb-S by solubility test, alkaline gel electrophoresis; and for G6PD deficiency, by fluorescent spot test. Results: Out of the 1150 donors, 23 (2% were diagnosed for SCT, 9 (0.78% for G6PD deficiency and 4 (0.35% for both conditions. Our prevalence of SCT and G6PD deficiency is higher than that of the general population of Riyadh. Conclusion: We recommend to screen all units for G6PD deficiency and sickle cell trait and to defer donations from donors with either of these conditions, unless if needed for special blood group compatibility, platelet apheresis or if these are likely to affect the blood bank inventory. If such blood is to be used, special precautions need to be undertaken to avoid complications in high-risk recipients.

  2. Association between maternal diet factors and hemoglobin levels, glucose tolerance, blood pressure and gestational age in a Hispanic population.

    Science.gov (United States)

    Soto, Roxana; Guilloty, Natacha; Anzalota, Liza; Rosario, Zaira; Cordero, José F; Palacios, Cristina

    2015-06-01

    The aim of this study was to describe the dietary patterns of pregnant women in northern Puerto Rico and explore associations between diet factors with pregnancy related measurements. This analysis is based on the Puerto Rico Testsite for Exploring Contamination Threats (PROTECT), a prospective cohort that is studying environmental risk factors for preterm births in PR. Participants completed a food frequency questionnaire (FFQ) around 20-28 weeks of gestation. The following pregnancy related measures were collected from the medical records: hemoglobin, blood glucose, blood pressure and gestational age. Potential associations between diet factors and pregnancy measures were assessed using chi square analysis with SPSS. A total of 180 participants completed the FFQ; low hemoglobin levels was found in 19.2%, high blood glucose levels was found in 21.1% by fasting blood glucose test and 24.6%by 1-hour 50 g oral glucose screening test, high blood pressure was found in 2.9% (systolic) and 6.5% (diastolic), and pre-term birth was found in 10.4% of the participants. High consumption of rice, desserts and sweets was associated with higher levels of fasting blood glucose levels (p desserts, can lead to high levels of blood glucose and can be a potential predictor of other pregnancy complications during pregnancy in these study participants, such as gestational diabetes. PMID:26817380

  3. Role of SGK1 in Salt Sensitivity of Blood Pressure and Peripheral Glucose Uptake: Studies in Knockout Mice

    OpenAIRE

    Boini, Krishna Murthy

    2006-01-01

    Excess salt intake increases blood pressure particularly during states of hyperinsulinism and insulin resistance. Insulin is presumably effective through activation of ENaC. Excess salt intake further decreases peripheral glucose uptake thus impairing glucose tolerance. Stimulation of both, the epithelial Na+ channel ENaC and of cellular glucose uptake involves phosphatidylinositide 3-kinase (PI-3K) which signals through protein kinase B (Akt/PKB) and all three members of the serum and glucoc...

  4. Investigation the effect of Commiphora mukul on blood glucose and Serum lipid profile in diabetic rats

    Directory of Open Access Journals (Sweden)

    leila Shirazi

    2015-01-01

    Full Text Available Background & aim: The decrease of serum glucose level and lipids in diabetic patients is clinically significant. The purpose of this study was to determine the effect of Commiphora mukul extract on blood sugar and lipid profile in diabetic rats. Methods: In the present experimental study, thirty-two male Wistar rats were randomly divided into four groups: control, control treated with the extract, diabetic and diabetic treated with the extract. Diabetes was induced by intraperitoneal injection of Streptozotocin. In an eight week period, the control group of normal saline and the control group and diabetic recipient extract of CM oleo gum blue resin was given by gavage. Treatment resumed eight weeks with onset of hyperglycemia. The control and diabetic control groups received normal saline orally. Extract treated control and extract treated diabetic groups received extract of Commiphora mukul gum (300 mg/kg P.O. daily by gavage. At the end of this period, blood samples were collected from each rat and biochemical tests for investigation of glucose level and lipid profile was performed. One- way analysis of variance (ANOVA statistical test and Post-hoc test Tukey’s were used for data analysis Results: The study indicated that diabetes increases the serum levels of glucose, cholesterol, triglycerides, LDL and HDL. Administration of Commiphora mukul gum extract in diabetic groups significantly decreased the serum level of glucose, cholesterol(p<0.01 and triglyceride and LDL(p<0.001 and increased HDL(p<0.01. Conclusion: Commiphora mukul gum extract may well improve undesirable effects of diabetes on serum level of glucose, cholesterol, triglyceride, LDL and HDL.

  5. Blood glucose may be an alternative to cholesterol in CVD risk prediction charts

    Science.gov (United States)

    2013-01-01

    Background Established risk models for the prediction of cardiovascular disease (CVD) include blood pressure, smoking and cholesterol parameters. The use of total cholesterol for CVD risk prediction has been questioned, particularly for primary prevention. We evaluated whether glucose could be used instead of total cholesterol for prediction of fatal CVD using data with long follow-up. Methods We followed-up 6,095 men and women aged ≥16 years who participated 1977-79 in a community based health study and were anonymously linked with the Swiss National Cohort until the end of 2008. During follow-up, 727 participants died of CVD. Based on the ESC SCORE methodology (Weibull regression), we used age, sex, blood pressure, smoking, and fasting glucose or total cholesterol. The mean Brier score (BS), area under the receiver-operating characteristic curve (AUC) and integrated discrimination improvement (IDI) were used for model comparison. We validated our models internally using cross-validation and externally using another data set. Results In our models, the p-value of total cholesterol was 0.046, that of glucose was p < 0.001. The model with glucose had a slightly better predictive capacity (BS: 2216x10-5 vs. 2232x10-5; AUC: 0.9181 vs. 0.9169, IDI: 0.009 with p-value 0.026) and could well discriminate the overall risk of persons with high and low concentrations. The external validation confirmed these findings. Conclusions Our study suggests that instead of total cholesterol glucose can be used in models predicting overall CVD mortality risk. PMID:23351551

  6. Altered baseline blood volume and the norepinephrine response to stress in humans

    Science.gov (United States)

    Vernikos, J.; Convertino, V. A.

    1992-01-01

    A hypothesis is proposed that a primary physiological purpose of the neural and endocrine response to stressors is the preservation of the blood volume/blood pressure relationship. Changes in blood volume caused by an adaptation to the environmental challenge serve to modulate the neural and endocrine responsiveness to stress. Relationships between changes in vascular volume, vasoconstriction, and norepinephrine (NE) responses during acute and chronic exposure to various stressors are examined. It is noted that the hypothesis is based on numerous observations rather than definitive cause-effect experiments and further investigation is required to prove it.

  7. Performance of two updated blood glucose monitoring systems: an evaluation following ISO 15197:2013.

    Science.gov (United States)

    Pleus, Stefan; Baumstark, Annette; Rittmeyer, Delia; Jendrike, Nina; Haug, Cornelia; Freckmann, Guido

    2016-05-01

    Objective For patients with diabetes, regular self-monitoring of blood glucose (SMBG) is essential to ensure adequate glycemic control. Therefore, accurate and reliable blood glucose measurements with SMBG systems are necessary. The international standard ISO 15197 describes requirements for SMBG systems, such as limits within which 95% of glucose results have to fall to reach acceptable system accuracy. The 2013 version of this standard sets higher demands, especially regarding system accuracy, than the currently still valid edition. ISO 15197 can be applied by manufacturers to receive a CE mark for their system. Research design and methods This study was an accuracy evaluation following ISO 15197:2013 section 6.3 of two recently updated SMBG systems (Contour * and Contour TS; Bayer Consumer Care AG, Basel, Switzerland) with an improved algorithm to investigate whether the systems fulfill the requirements of the new standard. For this purpose, capillary blood samples of approximately 100 participants were measured with three test strip lots of both systems and deviations from glucose values obtained with a hexokinase-based comparison method (Cobas Integra † 400 plus; Roche Instrument Center, Rotkreuz, Switzerland) were determined. Percentages of values within the acceptance criteria of ISO 15197:2013 were calculated. This study was registered at clinicaltrials.gov (NCT02358408). Main outcome Both updated systems fulfilled the system accuracy requirements of ISO 15197:2013 as 98.5% to 100% of the results were within the stipulated limits. Furthermore, all results were within the clinically non-critical zones A and B of the consensus error grid for type 1 diabetes. Conclusions The technical improvement of the systems ensured compliance with ISO 15197 in the hands of healthcare professionals even in its more stringent 2013 version. Alternative presentation of system accuracy results in radar plots provides additional information with certain advantages. In addition

  8. Simultaneous measurement of blood flow and glucose metabolism by autoradiographic techniques

    Energy Technology Data Exchange (ETDEWEB)

    Mies, G.; Niebuhr, I.; Hossmann, K.A.

    A double tracer autoradiographic technique using 131I-iodo-antipyrine and 14C-deoxyglucose is presented for the simultaneous measurement of blood flow and cerebral glucose utilization in the same animal. 131I is a gamma emitting isotope with a half life of 8.06 days and can be detected with adequate resolution on standard autoradiographic films. Autoradiograms are made before and after decay of 131I; the time interval between the 2 exposures and the concentration of the 2 tracers is adjusted to avoid significant cross-contamination. In this way, 2 film exposures are obtained which can be processed quantitatively like single tracer autoradiograms. The validity of the method for the investigation of local coupling of flow and metabolism was tested under various physiological and pathophysiological conditions. Coupling was tight in barbiturate-anesthetized healthy animals, but not under halothane anesthesia where uncoupling occurred in various subcortical structures. Focal seizures induced by topical application of penicillin on the cortical surface led to a coupled increase of metabolism and flow in thalamic relay nuclei but not at the site of penicillin administration where increased glucose utilization was not accompanied by similar increase in blood flow. Both coupled and uncoupled increases in local glucose utilization were observed in spreading depression and in circumscribed areas of experimental brain tumors. The results obtained demonstrate that double tracer autoradiography allows allows the very precise local assessment of cerebral blood flow and glucose utilization, and, therefore, is particularly suited to the study of regional coupling processes under various experimental conditions.

  9. Simultaneous measurement of blood flow and glucose metabolism by autoradiographic techniques

    International Nuclear Information System (INIS)

    A double tracer autoradiographic technique using 131I-iodo-antipyrine and 14C-deoxyglucose is presented for the simultaneous measurement of blood flow and cerebral glucose utilization in the same animal. 131I is a gamma emitting isotope with a half life of 8.06 days and can be detected with adequate resolution on standard autoradiographic films. Autoradiograms are made before and after decay of 131I; the time interval between the 2 exposures and the concentration of the 2 tracers is adjusted to avoid significant cross-contamination. In this way, 2 film exposures are obtained which can be processed quantitatively like single tracer autoradiograms. The validity of the method for the investigation of local coupling of flow and metabolism was tested under various physiological and pathophysiological conditions. Coupling was tight in barbiturate-anesthetized healthy animals, but not under halothane anesthesia where uncoupling occurred in various subcortical structures. Focal seizures induced by topical application of penicillin on the cortical surface led to a coupled increase of metabolism and flow in thalamic relay nuclei but not at the site of penicillin administration where increased glucose utilization was not accompanied by similar increase in blood flow. Both coupled and uncoupled increases in local glucose utilization were observed in spreading depression and in circumscribed areas of experimental brain tumors. The results obtained demonstrate that double tracer autoradiography allows allows the very precise local assessment of cerebral blood flow and glucose utilization, and, therefore, is particularly suited to the study of regional coupling processes under various experimental conditions

  10. Impaired first-phase insulin response predicts postprandial blood glucose increment in patients with recently diagnosed type 2 diabetes

    DEFF Research Database (Denmark)

    Gredal, C; Rosenfalck, A M; Dejgaard, Anders;

    2007-01-01

    The aim of the study was to evaluate the relationship between postprandial blood glucose and first-phase insulin response and, furthermore, to assess whether the intravenous glucagon stimulation test can be used as a predictor for increased postprandial glucose in patients with recently diagnosed...... type 2 diabetes....

  11. Effect of glucose on photoacoustic signals at the wavelengths of 1064 and 532 nm in pig blood and intralipid

    International Nuclear Information System (INIS)

    Non-invasive glucose monitoring is one of the most active areas in biomedical research. Various techniques have been developed over the years to meet the clinical requirements of non-invasive monitoring in the physiologically relevant glucose concentration range, but without a breakthrough. This paper used the pulsed photoacoustic (PA) technique to study glucose-induced changes in pig whole blood and 1% IntralipidTM using an Nd : YAG laser with wavelengths of 1064 and 532 nm as the optical energy source. Scattering properties of the sample significantly affect the laser-induced pressure waves. Glucose was found to affect both the scattering and the absorption properties of the samples. The results showed an increase of 11.4%/500 mg dl-1 added glucose in the peak-to-peak value of the PA signal in blood at 1064 nm, whereas the corresponding increase was only 1.35%/500 mg dl-1 in 1% IntralipidTM. At a wavelength of 532 nm, the glucose increased the peak-to-peak value of the PA signal by 6.0%/500 mg dl-1 added glucose in blood. On the whole, the pulsed PA technique proved to be an efficient tool for the study of glucose-induced changes in blood and tissue phantoms in vitro

  12. A Comparative Study of Blood Glucose Measurements Using Glucometer Readings and the Standard Method in the Diagnosis of Neonatal Hypoglycemia

    Directory of Open Access Journals (Sweden)

    Mohammad Torkaman

    2016-03-01

    Full Text Available Background: Hypoglycemia is one of the most common neonatal disorders, associated with severe complications. There has been a great deal of controversy regarding the definition and screening of hypoglycemia. Therefore, in this study, we aimed to determine a cut-off value for blood glucose level in glucometer readings. Methods: This cross-sectional study was conducted on 238 newborns at risk of hypoglycemia, admitted to Baqiyatallah Hospital of Tehran, Iran in 2012; the subjects were selected via simple sampling. After obtaining informed consents from the newborns’ parents, 1 cc blood samples were sent to the laboratory for measuring the blood glucose level. Moreover, venous blood samples, as well as heel-stick blood samples, were obtained for glucometer measurements. Blood glucose measurements were used to determine the cut-off value by the receiver operating characteristic (ROC curve and make comparisons with the diagnostic criteria for hypoglycemia in the literature. Results: A total of 238 infants with the mean weight of 2869±821.9 g were enrolled in this study. The mean (±SD blood glucose levels were 65.1±22.9, 82.9±24.7, and 84.4±24.8 mg/dl, based on the standard laboratory method, glucometer reading of venous blood samples, and glucometer reading of heel-stick capillary blood samples, respectively. The optimal cut-off point for hypoglycemia was determined as 65 mg/dl, using glucometer-based assessment of heel-stick blood samples. Conclusion: The significant difference in blood glucose levels measured by the laboratory method and outpatient glucometer readings highlights the importance of a cut-off value for rapid assessment and control of blood glucose and timely detection of hypoglycemia. In fact, the cut-off value introduced in the present study could facilitate such measurements.

  13. An enzymatic glucose/O2 biofuel cell operating in human blood.

    Science.gov (United States)

    Cadet, Marine; Gounel, Sébastien; Stines-Chaumeil, Claire; Brilland, Xavier; Rouhana, Jad; Louerat, Frédéric; Mano, Nicolas

    2016-09-15

    Enzymatic biofuel cells (BFCs) may power implanted medical devices and will rely on the use of glucose and O2 available in human bodily fluids. Other than well-established experiments in aqueous buffer, little work has been performed in whole human blood because it contains numerous inhibiting molecules. Here, we tested our BFCs in 30 anonymized, random and disease-free whole human blood samples. We show that by designing our anodic and cathodic bioelectrocatalysts with osmium based redox polymers and home-made enzymes we could reach a high selectivity and biofunctionnality. After optimization, BFCs generate power densities directly proportional to the glycaemia of human blood and reached a maximum power density of 129µWcm(-2) at 0.38V vs. Ag/AgCl at 8.22mM glucose. This is to our knowledge the highest power density attained so far in human blood and open the way for the powering of integrated medical feedback loops. PMID:27107143

  14. The Effect of Abelmoschus Esculentus on Blood Levels of Glucose in Diabetes Mellitus

    Science.gov (United States)

    Khosrozadeh, Maryam; Heydari, Naval; Abootalebi, Malihe

    2016-01-01

    Background: Diabetes mellitus is a metabolic disorder that results in hyperglycemia. According to the statistics of the International Diabetes Federation (IDF), this problem has a fast growing prevalence and, unfortunately, leaves permanent complications on different body systems. For this reasons, nowadays attentions has been paid to the traditional medicine such as Okra (Abelmoscus esculentus). The aim of this study was the evaluation of the effect of Okra (Abelmoscus esculentus) on blood levels of glucose in diabetes. Methods: This is a review article, which was obtained by a search in databases such as PubMed, Google Scholar, and Magiran by using keywords such as diabetes, Okra, and hypoglycemic effect. Results: Various studies on Okra (Abelmoscus esculentus) showed that Abelmoscus esculentus (AE)/Okra extract has a hypoglycemic effect that helps decrease blood glucose level. Its properties can be a useful remedy to manage diabetes mellitus. In addition, it leads to inhibition of cholesterol absorption and subsequently decreases the level of lipid and fat in the blood. The results of an investigation on diabetic mice by using this material has shown the same effect and confirmed this conclusion. Conclusion: Based on the positive effects of Okra on reducing blood sugar level, the widespread use of this plant is recommended. Clearly, further research is required.

  15. Glucose Tests

    Science.gov (United States)

    ... be limited. Home Visit Global Sites Search Help? Glucose Tests Share this page: Was this page helpful? ... the meaning of other test results. Fasting Blood Glucose Glucose Level Indication From 70 to 99 mg/ ...

  16. Analysis Article on the Performance Analysis of the OneTouch® UltraVue™ Blood Glucose Monitoring System

    OpenAIRE

    Solnica, Bogdan

    2009-01-01

    In this issue of Journal of Diabetes Science and Technology, Chang and colleagues present the analytical performance evaluation of the OneTouch® UltraVue™ blood glucose meter. This device is an advanced construction with a color display, used-strip ejector, no-button interface, and short assay time. Accuracy studies were performed using a YSI 2300 analyzer, considered the reference. Altogether, 349 pairs of results covering a wide range of blood glucose concentrations were analyzed. Patients ...

  17. Patterns of self-monitoring of blood glucose in insulin-treated diabetes: analysis of a Scottish population over time.

    Science.gov (United States)

    Cameron, D; Harris, F M; Evans, J M M

    2016-07-01

    Analysis of a diabetes clinical information system in Tayside, Scotland, shows that a significant proportion of insulin-treated patients with diabetes are not self-monitoring blood glucose according to current clinical guidance and recommendations, with some not self-monitoring their blood glucose at all. Although there has been an increase in the number of reagent strips dispensed over the past decade, this increase is mainly accounted for by increased testing frequency among people with diabetes already testing. PMID:26990502

  18. Effects of Mad Honey on Blood Glucose and Lipid Levels in Rats With Streptozocin-Induced Diabetes

    OpenAIRE

    ÖZTAŞAN, Nuray

    2005-01-01

    This study investigated whether mad honey affects blood glucose and lipid levels in experimental animals. It was found that mad honey caused significant decreases in blood glucose and lipid levels in animals with streptozocin-induced diabetes mellitus (n = 10) and controls (n = 10). These decreases may be due to grayanotoxins in the mad honey causing the islets of Langerhans in the pancreas to secrete insulin by stimulating the parasympathetic nervous system or M2-muscarinic receptors.

  19. Effects of exposure to electromagnetic field radiation (EMFR) generated by activated mobile phones on fasting blood glucose

    OpenAIRE

    Sultan Ayoub Meo; Khalid Al Rubeaan

    2013-01-01

    Objective: Extensive use of mobile phones has been accompanied by a common public debate about possible adverse effects on human health. No study has been published so far to establish any association between the fastest growing innovation of mobile phone and fasting blood glucose. The aim was to determine the effects of exposure to electromagnetic field radiation generated by mobile phones on fasting blood glucose in Wistar Albino rats. Materials and Methods: 40 Male Albino rats (Wistar Stra...

  20. Blood Glucose as a Predictor of Mortality in Children Admitted to the Hospital with Febrile Illness in Tanzania

    OpenAIRE

    Nadjm, Behzad; Mtove, George; Amos, Ben; Hildenwall, Helena; Najjuka, Anne; Mtei, Frank; Todd, Jim; Reyburn, Hugh

    2013-01-01

    Data from a prospective study of 3,319 children ages 2 months to 5 years admitted with febrile illness to a Tanzanian district hospital were analyzed to determine the relationship of blood glucose and mortality. Hypoglycemia (blood sugar < 2.5 mmol/L and < 45 mg/dL) was found in 105 of 3,319 (3.2%) children at admission, and low-normal blood glucose (2.5-5 mmol/L and 45-90 mg/dL) was found in 773 of 3,319 (23.3%) children. Mortality was inversely related to admission blood sugar; compared wit...

  1. Diabetes screening and the distribution of blood glucose levels in rural areas of North India

    Directory of Open Access Journals (Sweden)

    Tomi Thomas

    2015-01-01

    Full Text Available Background and Objectives: Genetics and environment have both been implicated in the exponential rise in the prevalence of diabetes mellitus that affects 65.1 million people, and leads to a mortality of 1 million people every year in India. This study was devised to obtain the trends of the distribution of blood glucose, and sociodemographic characteristics in rural areas of a North Indian state. Materials and Methods: A cross-sectional study was conducted at eight centers in five districts. A camp-based approach was followed in the diabetes screening conducted in rural areas. Blood glucose measurements were obtained after informed consent by trained staff using a reflectance photometer instrument. Descriptive statistics, distribution curves, log transformations, and tests for bimodality were obtained. Results: 45,318 participants consisting of 44.4% males and 55.6% females were screened. Ages ranged from 18 to 98 years with the mean age of 39.9 ± 14.44 years. 86.5% were normal (random blood sugar [RBS] 200 mg/dl. The median blood glucose level steadily rose with increasing age. The prediabetic to diabetic ratio was 4:1. The distribution curve of RBS was right skewed. A log transformation was applied, and bimodality was tested using the Hartigan′s dip test. The dip statistic (D was 0.0162 with a simulated P < 0.001. Conclusion: Mass screening for diabetes provides benefits from a clinical standpoint by helping to estimate the prevalence (diabetes and the hidden burden of the disease (prediabetes. Screening programs can strengthen healthcare system initiatives and reduce the growing burden of diabetes in India.

  2. Emotional arousal, blood glucose levels, and memory modulation: three laboratory exercises in cognitive neuroscience.

    Science.gov (United States)

    Flint, Robert W

    2004-01-01

    The relationships between emotional arousal and cognition in humans represent an important field in cognitive neuroscience. Studies examining the characteristics of emotion-induced memory enhancement and the mechanisms through which these effects occur are becoming increasingly common. This article describes three affordable laboratory exercises of relevance to the growing interest in this field. Specifically, Experiment one reviews a protocol for examining memory, hypermnesia, reminiscence, and primacy/recency effects for emotional and neutral words. Experiments two and three provide opportunities to examine the relationships between blood glucose level and memory for either a list of pictures or the spatial location of pictures. Each laboratory exercise contains a certain amount of flexibility and is malleable to the specific needs of the instructor. For example, the use of blood glucose monitoring may be of value to a variety of different exercises examining stress and/or emotional arousal and the stimuli used in each of the protocols may be varied, creating opportunities for a number of different novel exercises. A series of questions have been provided at the end of each exercise in order to help stimulate inclass discussion. The potential application of this line of research in cognitive neuroscience is conveyed through a list of references where glucose has been used to attenuate cognitive deficits in Alzheimer's disease, age-related cognitive decline, and other neuropsychological conditions. PMID:23493939

  3. Low blood glucose levels and other complications during growth hormone supplementation in sepsis

    Directory of Open Access Journals (Sweden)

    Faintuch Joel

    1999-01-01

    Full Text Available Blood glucose levels in the high normal range or even moderate hyperglycemia is the expected profile in septic postoperative patients receiving high-calorie enteral alimentation. The addition of growth hormone as an anabolic agent should additionally reinforce this tendency. In a cancer patient undergoing partial gastrectomy with lymphadenectomy and suffering from postoperative subphrenic abscess and prolonged sepsis, tube feeding (38.3 kcal/kg/day and growth hormone (0.17 IU/kg/day were simultaneously administered for 25 days. Blood glucose levels were in the lower limits of the normal range before growth hormone introduction, and continued with a similar tendency during most of the therapeutic period. Two additional complications, namely heart arrest and peripheral edema, were documented during the same period. It is concluded that sepsis was the most likely mechanism for low glucose values, and that high-calorie enteral diet and growth hormone supplementation did not prevent that result. It is uncertain whether heart arrest was due to the drug, but its association with peripheral edema is well documented in clinical series.

  4. Profile of blood glucose and ultrastucture of beta cells pancreatic islet in alloxan compound induced rats

    Directory of Open Access Journals (Sweden)

    I Nyoman Suarsana

    2010-06-01

    Full Text Available Diabetes is marked by elevated levels of blood glucose, and progressive changes of the structure of pancreatic islet histopathology. The objective of this research was to analyse the glucose level and histophatological feature in pancreatic islet in alloxan compound induced rats. A total of ten male Spraque Dawley rats of 2 months old were used in this study. The rats were divided into two groups: (1 negative control group (K-, and (2 positif induced alloxan group (diabetic group =DM. The rats were induced by a single dose intraperitonial injection of alloxan compound 120 mg/kg of body weight. The treatment was conducted for 28 days. Blood glucose levels of rats were analysed at 0, 4, 7, 14, 21, and 28 days following treatment. At the end of the experiment, rats were sacrificed by cervical dislocation. Pancreas was collected for analysis of histopathological study by Immunohistochemical technique, and ultrastructural study using transmission electron microscope (TEM. The result showed that Langerhans islet of diabetic rat (rat of DM group showed a marked reduction of size, number of Langerhans islet of diabetic rat decrease, and characterized by hyperglycemic condition. By using TEM, beta cells of DM group showed the rupture of mitochondrial membrane, the lost of cisternal structure of inner membrane of mitocondria, reduction of insulin secretory granules, linkage between cells acinar with free Langerhans islet, and the caryopicnotic of nucleus.

  5. Bihormonal model predictive control of blood glucose in people with type 1 diabetes

    DEFF Research Database (Denmark)

    Batora, Vladimir; Tarnik, Marian; Murgas, Jan;

    2014-01-01

    In this paper we present a bihormonal control system that controls blood glucose in people with type 1 diabetes (T1D). We use insulin together with glucagon to mitigate the negative effects of hyper- and hypoglycemia. The system consists of a Kalman filter, a micro-bolus insulin and glucagon...... with an identical insulin MPC, but a glucagon PD controller. The key contribution of the bihormonal MPC is the efficiency of glucagon use. We consider scenarios where the meals are estimated correctly or overestimated and where the insulin sensitivity increases. Both solutions provide tight glucose...... infusion MPC, a mealtime bolus calculator and a CGM providing feedback to the controller. The controller employs a patient data-based prediction model with ARMAX structure. We test the controller using a bihormonal model with time-varying parameters for 3 subjects and compare its performance to a system...

  6. Effect of guar crispbread with cereal products and leguminous seeds on blood glucose concentrations of diabetics.

    Science.gov (United States)

    Jenkins, D J; Wolever, T M; Taylor, R H; Barker, H M; Fielden, H; Jenkins, A L

    1980-11-01

    To compare the effect on blood glucose concentrations of guar incorporated into crispbreads with that of unprocessed high-fibre foods groups of four to six diabetics took a total of seven test breakfasts on separate days. By comparison with a breakfast of wholemeal bread and cheese, guar crispbread combined with bread reduced the area under the glucose response curve to 51% (p soya beans reduced the area to 65% (p soya beans to 25% (p soya beans with lentils to 29% (p < 0.002). Porridge and cornflake breakfasts showed no difference. The favourable results with leguminous seeds may not make such meals more acceptable than meals of guar products, but a combination of leguminous seeds and guar may allow smaller and more acceptable amounts of both to be used. PMID:6253021

  7. Cerebral oxygen and glucose metabolism and blood flow in mitochondrial encephalomyopathy: a PET study

    International Nuclear Information System (INIS)

    Cerebral blood flow (CBF), oxygen metabolism (CMRO2), and glucose metabolism (CMRGlc) were measured using positron emission tomography in five patients diagnosed as having mitochondrial encephalomyopathy. The molar ratio between the oxygen and glucose consumptions was reduced diffusely, as CMRO2 was markedly decreased and CMRGlc was slightly reduced. The CBF showed less changes. The CBF increase on hypercapnia was smaller than normal, though this was not significant. CBF with hypocapnia demonstrated a significant reduction compared with the normal. These results suggest that oxidative metabolism is impaired and anaerobic glycolysis relatively stimulated, due to a primary defect of mitochondrial function, and that mild lactic acidosis occurs in brain tissue because of impaired utilisation of pyruvate in the TCA cycle. As these findings appear to indicate directly a characteristic of this disease, such measurements may be a useful tool for assessment of the pathophysiology and for diagnosis of mitochondrial encephalomyopathy. (orig.). With 1 fig., 4 tabs

  8. Effects of Cinnamomum zeylanicum (Ceylon cinnamon) on blood glucose and lipids in a diabetic and healthy rat model

    OpenAIRE

    Priyanga Ranasinghe; Sanja Perera; Mangala Gunatilake; Eranga Abeywardene; Nuwan Gunapala; Sirimal Premakumara; Kamal Perera; Dilani Lokuhetty; Prasad Katulanda

    2012-01-01

    Objectives: To evaluate short- and long-term effects of Cinnamomum zeylanicum on food consumption, body weight, glycemic control, and lipids in healthy and diabetes-induced rats. Materials and Methods: The study was conducted in two phases (Phase I and Phase II), using Sprague-Dawley rats in four groups. Phase I evaluated acute effects on fasting blood glucose (FBG) (Groups 1 and 2) and on post-oral glucose (Groups 3 and 4) blood glucose. Groups 1 and 3 received distilled-water and Groups 2 a...

  9. Breath acetone concentration decreases with blood glucose concentration in type I diabetes mellitus patients during hypoglycaemic clamps

    OpenAIRE

    Turner, Claire; Walton, Christopher; Hoashi, Shu; Evans, Mark

    2009-01-01

    Conventional wisdom is that breath acetone may be markedly elevated in type 1 diabetes, but that this only occurs during poor blood glucose control and/or intercurrent illness. In contrast, little is known about breath acetone at more representative everyday blood glucose levels in diabetes. We used selected ion flow tube mass spectrometry (SIFT-MS) to monitor the breath of 8 patients with type 1 diabetes mellitus during “insulin clamp” studies in which insulin and glucose were infused into p...

  10. EFFECT OF VITAMIN C ON BLOOD GLUCOSE LEVEL IN RABBITS AND ITS POSSIBLE INTERACTION WITH COMMONLY USED ANTI DIABETIC AGENTS.

    Directory of Open Access Journals (Sweden)

    Chandra Veer Singh

    2015-03-01

    Full Text Available A Effect of Vitamin C on blood glucose and its possible interactions with oral Antidiabetic agents (i.e. Glimepiride, Gliclazide and Metformin in rabbits have been reported in the present study. The study was performed on albino rabbits in which hyperglycemia was induced by giving glucose. We observed that vit.C significantly lowered the blood glucose level but on co-administration with oral antidiabetic agents it antagonized the effect of the latter drugs. It is therefore advisable not to give inadvertent amount of vit.C to diabetic patients just in a belief that antioxidants are helpful to diabetics and do not produce adverse effects.

  11. Investigation of the Blood Glucose Lowering Potential of the Jamaican Momordica charantia (Cerasee) Fruit in Sprague-Dawley Rats.

    Science.gov (United States)

    Burnett, A; McKoy, M L; Singh, P

    2015-09-01

    The Momordica charantia (MC) fruit has been documented to possess antidiabetic properties. However, these studies were not without controversy surrounding the blood glucose-lowering ability and the mechanism of action in diabetes therapy. In an effort to evaluate such claims in the Jamaican MC species known as cerasee, aqueous extracts of the unripe fruit were studied in normal and diabetic rats. Normal male Sprague-Dawley rats were divided into groups (n = 6) orally administered distilled water, 10% dimethyl sulfoxide (DMSO) solution, the aqueous extract (400 mg/kg body weight) and glibenclamide (15 mg/kg body weight), respectively prior to assessment of fasting blood glucose (FBG) concentration. The oral glucose tolerance test (OGTT) was conducted in normoglycaemic rats orally administered distilled water, 10% DMSO solution, glibenclamide (15 mg/kg body weight) or aqueous extracts of the fruit (200 and 400 mg/kg body weight). Blood glucose concentration was also monitored in streptozotocin-induced diabetic rats administered the aqueous extract (250 mg/kg body weight) or water vehicle after an overnight fast. The aqueous extracts showed no hypoglycaemic or antidiabetic activity. However, the administration of the aqueous extracts (200 and 400 mg/kg body weight) resulted in significant improvement in glucose tolerance of glucose-primed normoglycaemic rats during the OGTT. These data suggest that the glucose-lowering mechanism of the Jamaican MC fruit species likely involves altered glucose absorption across the gastrointestinal tract. PMID:26624580

  12. Alternate Immersion in an External Glucose Solution Differentially Affects Blood Sugar Values in Older Versus Younger Zebrafish Adults.

    Science.gov (United States)

    Connaughton, Victoria P; Baker, Cassandra; Fonde, Lauren; Gerardi, Emily; Slack, Carly

    2016-04-01

    Recently, zebrafish have been used to examine hyperglycemia-induced complications (retinopathy and neuropathy), as would occur in individuals with diabetes. Current models to induce hyperglycemia in zebrafish include glucose immersion and streptozotocin injections. Both are effective, although neither is reported to elevate blood sugar values for more than 1 month. In this article, we report differences in hyperglycemia induction and maintenance in young (4-11 months) versus old (1-3 years) zebrafish adults. In particular, older fish immersed in an alternating constant external glucose solution (2%) for 2 months displayed elevated blood glucose levels for the entire experimental duration. In contrast, younger adults displayed only transient hyperglycemia, suggesting the fish were acclimating to the glucose exposure protocol. However, modifying the immersion protocol to include a stepwise increasing glucose concentration (from 1% → 2%→3%) resulted in maintained hyperglycemia in younger zebrafish adults for up to 2 months. Glucose-exposed younger fish collected after 8 weeks of exposure also displayed a significant decrease in wet weight. Taken together, these data suggest different susceptibilities to hyperglycemia in older and younger fish and that stepwise increasing glucose concentrations of 1% are required for maintenance of hyperglycemia in younger adults, with higher concentrations of glucose resulting in greater increases in blood sugar values. PMID:26771444

  13. Cerebral blood flow, glucose use, and CSF ionic regulation in potassium-depleted rats

    International Nuclear Information System (INIS)

    Rats were kept on a low-K+ diet for 25 or 70 days. Local cerebral blood flow (LCBF) and local cerebral glucose utilization (LCGU) were measured in 31 different structures of the brain by means of the [14C]iodoantipyrine and [14C]2-deoxy-D-glucose method. After 25 and 70 days of K+ depletion LCBF was decreased significantly in 27 and 30 structures, respectively, the average decrease being 19 and 25%. In contrast, average LCGU was not changed. Cisternal cerebrospinal fluid (CSF) K+ concentration decreased significantly from 2.65 ± 0.02 mM in controls to 2.55 ± 0.02 mM and 2.47 ± 0.02 mM in the two treated groups. CSF [HCO3-], pH, and Pco2 were increased in K+-depleted animals. These data show that K+ depletion induces an increase in CSF pH and a decrease in CSF K+ concentration, both of which cause a reduction in cerebral blood flow. The increased CSF Pco2 is secondary to the reduction of blood flow, since brain metabolism and arterial Pco2 remained constant

  14. GUAR GUM EFFECTS ON BLOOD SERUM LIPIDS AND GLUCOSE CONCENTRATIONS OF WISTAR DIABETIC RATS1

    Directory of Open Access Journals (Sweden)

    DARIO FRIAS Andrea

    1998-01-01

    Full Text Available The effects of guar gum derived from the endosperm of Cyamopsis tetragonoloba (75% soluble fiber, 7.6% insoluble fiber, 2.16% crude protein, 0.78% total lipids, 0.54% ash and 9.55% moisture on diabetic rats were studied concerning food intake, body weight gain, blood serum cholesterol, triacylglycerols, glucose, LDL-, and HDL-cholesterol concentrations. The effect of gum on indexes of protein absorption and utilization was also investigated. Diets containing 0%, 10% and 20% (w/w guar gum were fed to diabetic rats for 28 days. In spite of the fact that diabetes elevated blood lipids in all animals, guar gum diet significantly decreased (p <0.05 serum concentrations of cholesterol and triacylglycerols. Furthermore, a concomitant increase in HDL-cholesterol with a substancial elevation of the HDL/LDL cholesterol ratio was found. The most significant result in this assay was the drastic reduction of blood glucose in diabetic rats treated with guar gum diet. The gum promoted a general improvement in the condition of the diabetic rats, in body weight gain and indexes of protein absorption and utilization. The results of this research suggest that guar gum, at concentrations equal to or higher than 10%, should be effective in the treatment of hypercholesterolemia and diabetes, in humans.

  15. Association between DNA Methylation in Whole Blood and Measures of Glucose Metabolism: KORA F4 Study

    Science.gov (United States)

    Wahl, Simone; Kunze, Sonja; Molnos, Sophie; Volkova, Nadezda; Schramm, Katharina; Carstensen-Kirberg, Maren; Waldenberger, Melanie; Gieger, Christian; Peters, Annette; Illig, Thomas; Prokisch, Holger; Roden, Michael; Grallert, Harald

    2016-01-01

    Epigenetic regulation has been postulated to affect glucose metabolism, insulin sensitivity and the risk of type 2 diabetes. Therefore, we performed an epigenome-wide association study for measures of glucose metabolism in whole blood samples of the population-based Cooperative Health Research in the Region of Augsburg F4 study using the Illumina HumanMethylation 450 BeadChip. We identified a total of 31 CpG sites where methylation level was associated with measures of glucose metabolism after adjustment for age, sex, smoking, and estimated white blood cell proportions and correction for multiple testing using the Benjamini-Hochberg (B-H) method (four for fasting glucose, seven for fasting insulin, 25 for homeostasis model assessment-insulin resistance [HOMA-IR]; B-H-adjusted p-values between 9.2x10-5 and 0.047). In addition, DNA methylation at cg06500161 (annotated to ABCG1) was associated with all the aforementioned phenotypes and 2-hour glucose (B-H-adjusted p-values between 9.2x10-5 and 3.0x10-3). Methylation status of additional three CpG sites showed an association with fasting insulin only after additional adjustment for body mass index (BMI) (B-H-adjusted p-values = 0.047). Overall, effect strengths were reduced by around 30% after additional adjustment for BMI, suggesting that this variable has an influence on the investigated phenotypes. Furthermore, we found significant associations between methylation status of 21 of the aforementioned CpG sites and 2-hour insulin in a subset of samples with seven significant associations persisting after additional adjustment for BMI. In a subset of 533 participants, methylation of the CpG site cg06500161 (ABCG1) was inversely associated with ABCG1 gene expression (B-H-adjusted p-value = 1.5x10-9). Additionally, we observed an enrichment of the top 1,000 CpG sites for diabetes-related canonical pathways using Ingenuity Pathway Analysis. In conclusion, our study indicates that DNA methylation and diabetes-related traits

  16. Effects of short term changes in the blood glucose level on the autofluorescence lifetime of the human retina in healthy volunteers

    Science.gov (United States)

    Klemm, Matthias; Nagel, Edgar; Schweitzer, Dietrich; Schramm, Stefan; Haueisen, Jens

    2016-03-01

    Purpose: Fluorescence lifetime imaging ophthalmoscopy (FLIO) provides in vivo metabolic mapping of the ocular fundus. Changes in FLIO have been found in e.g. diabetes patients. The influence of short term metabolic changes caused by blood glucose level changes on is unknown. Aim of this work is the detection of short-term changes in fundus autofluorescence lifetime during an oral glucose tolerance test. Methods: FLIO was performed in 10 healthy volunteers (29+/-4 years, fasting for 12h) using a scanning laser ophthalmoscope (30° fundus, 34μm resolution, excitation with 473nm diode laser with 70 ps pulses at 80 MHz repetition rate, detection in two spectral channels 500-560nm (ch1) and 560-720nm (ch2) using the timecorrelated single photon counting method). The blood glucose level (BGL) was measured by an Accu-Chek® Aviva self-monitoring device. Before and after a glucose drink (300ml solution, containing 75g of glucose (Accu-Chek® Dextrose O.G.T.), BGL and FLIO were measured every 15min. The FLIMX software package was applied to compute the average fluorescence lifetime τ on the inner ring of the ETDRS grid using a modified 3-exponential approach. Results: The results are given as mean +/- standard deviation over all volunteers in ch1. Baseline measurement: BGL: 5.3+/-0.4 mmol/l, τ1: 49+/-6ps. A significant reduction (α=5% Wilcoxon rank-sum test) in τ1 is detected after 15min (BGL: 8.4+/-1.1 mmol/l, τ1: 44+/-5ps) and after 90min (BGL: 6.3+/-1.4 mmol/l, τ1: 41+/-5ps). Results of ch2 show smaller reductions in the fluorescence lifetimes over time.

  17. Patient and healthcare professional satisfaction with a new, high accuracy blood glucose meter with color range indicator and wireless connectivity.

    Science.gov (United States)

    Katz, Laurence B; Grady, Mike; Stewart, Lorna; Cameron, Hilary

    2016-07-01

    Accurate self-monitoring of blood glucose is a key component of effective self-management of glycemic control. The OneTouch VerioFlex(™) (OTVF) blood glucose monitoring system (BGMS) was evaluated for accuracy in a clinical setting. Patients also used OTVF for a 1-wk trial period and reported their level of satisfaction with meter features. In a separate study, healthcare professionals used an on-line simulator of the BGMS and answered questions about its potential utility to their patients. OTVF was accurate over a wide glucose range and met lay user and system accuracy blood glucose standards described in ISO15197:2013 as well as the accuracy requirements to fulfill US FDA expectations for 510(k) clearance of BGMS. Patients and healthcare professionals felt the features of OTVF, which has the capability to connect wirelessly to mobile devices and interact wirelessly with diabetes management software, could provide significant benefits to them or their patients. PMID:27232211

  18. Studies on glucose metabolism and blood perfusion in childhood partial seizure by positron emission CT

    International Nuclear Information System (INIS)

    To investigate the glucose metabolism and blood perfusion of the interictal epileptic focus, 15 positron emission tomography (PET) measurements were performed in 14 children with partial seizures (2 with simple partial seizures, 2 with complex partial seizures, and 10 with partial seizures evolving to secondary generalized seizures), comprising 7 males and 7 females aged 1 to 12 years old at the onset of the epileptic seizures. The intervals between the seizure onset and PET examinations were 1 month to 7 years (mean 3 1/4 years). Radiopharmaceuticals such as 11C-glucose, 11CO2 and 11CO were used as indicators of local cerebral glucose metabolism, blood perfusion and blood flow, respectively. Apart from 2 cases, none of the patients showed abnormal x-ray computed tomographic scans (X-CT). The abnormal X-CT findings included cortical atrophy of the cerebrum apart from the epiletic focus in one case and cavum vergae in the other. Hypometabolism and hypoperfusion at the epileptic focus were observed in 10 patients undergoing single examinations who had suffered from epileptic seizures for more than 1 year. Out of 4 patients who had suffered from epileptic seizures for 1 year or less, one revealed a zone of hypometabolism and hypoperfusion in the epileptic focus and expanded region larger than that of the epileptic focus on the electroencephalogram. Two other patients revealed a zone of hypometabolism and hypoperfusion in an area contralateral to the epileptic focus. In the remaining one patient, PET examinations were performed twice. The initial PET pictures one year after seizure onset revealed a zone of hypermetabolism and hyperperfusion in the cerebellum ipsilateral to the epileptic focus, and the second PET at 6 months after the initial examination revealed hypometabolism and hypoperfusion in the focus, similarly to the 10 cases mentioned above. (J.P.N.)

  19. Evaluation of Glucose-6-Phosphate Dehydrogenase stability in stored blood samples

    OpenAIRE

    Jalil, Norunaluwar; Azma, Raja Zahratul; Mohamed, Emida; Ithnin, Azlin; Alauddin, Hafiza; Baya, Siti Noor; Othman, Ainoon

    2016-01-01

    Glucose-6-Phosphate Dehydrogenase (G6PD) deficiency is the commonest cause of neonatal jaundice in Malaysia. Recently, OSMMR2000-D G6PD Assay Kit has been introduced to quantitate the level of G6PD activity in newborns delivered in Universiti Kebangsaan Malaysia Medical Centre (UKMMC). As duration of sample storage prior to analysis is one of the matters of concern, this study was conducted to identify the stability of G6PD enzyme during storage. A total of 188 cord blood samples from normal ...

  20. A Soluble Activin Receptor Type IIB Does Not Improve Blood Glucose in Streptozotocin-Treated Mice

    OpenAIRE

    Wang, Qian; Guo, Tingqing; Portas, Jennifer; McPherron, Alexandra C.

    2015-01-01

    Type 1 diabetes mellitus (T1DM), or insulin dependent DM, is accompanied by decreased muscle mass. The growth factor myostatin (MSTN) is a negative regulator of muscle growth, and a loss of MSTN signaling has been shown to increase muscle mass and prevent the development of obesity, insulin resistance and lipodystrophic diabetes in mice. The effects of MSTN inhibition in a T1DM model on muscle mass and blood glucose are unknown. We asked whether MSTN inhibition would increase muscle mass and ...

  1. Integrated Self-Monitoring of Blood Glucose System: Handling Step Analysis

    OpenAIRE

    Freckmann, Guido; Schmid, Christina; Ruhland, Katharina; Baumstark, Annette; Haug, Cornelia

    2012-01-01

    Self-monitoring of blood glucose (SMBG) implicates a number of handling steps with the meter and the lancing device. Numerous user errors can occur during SMBG, and each step adds to the complexity of use. This report compares the required steps to perform SMBG of one fully integrated (the second generation of the Accu-Chek® Mobile), three partly integrated (Accu-Chek Compact Plus, Ascensia® Breeze®2, and Accu-Chek Aviva), and six conventional (Bayer Contour®, Bayer Contour USB, BGStar™, Free...

  2. Frequency and motives of blood glucose self-monitoring in type 1 diabetes

    DEFF Research Database (Denmark)

    Hansen, M.V.; Pedersen-Bjergaard, U.; Heller, S.R.;

    2009-01-01

    AIMS: Recommendations for self-monitoring of blood glucose (SMBG) from the DCCT have not been implemented with the same rigour as recommendations for intensifying insulin therapy. We assessed the frequency of and motives for SMBG and compared SMBG behaviour with clinical, behavioural and...... hypoglycaemia and awareness of hypoglycaemia were independently associated with testing behaviour, whereas the presence of late diabetic complications was not. Lower HbA1c was associated with more frequent testing. CONCLUSION: Patient compliance regarding SMBG is limited. Thus, almost two thirds of the patients...

  3. Baseline blood Pb levels of black-necked stilts on the upper Texas coast

    Science.gov (United States)

    Riecke, Thomas V.; Conway, Warren C.; Haukos, David A.; Moon, Jena A.; Comer, Christopher E.

    2015-01-01

    There are no known biological requirements for lead (Pb), and elevated Pb levels in birds can cause a variety of sub-lethal effects and mortality. Historic and current levels of Pb in mottled ducks (Anas fulvigula) suggest that environmental sources of Pb remain available on the upper Texas coast. Because of potential risks of Pb exposure among coexisting marsh birds, black-necked stilt (Himantopus mexicanus) blood Pb concentrations were measured during the breeding season. Almost 80 % (n = 120) of 152 sampled stilts exceeded the background threshold (>20 μg/dL) for Pb exposure. However, blood Pb concentrations did not vary by age or gender, and toxic or potentially lethal concentrations were rare (Pb concentrations of black-necked stilts in this study suggest the presence of readily bioavailable sources of Pb, although potential impacts on local stilt populations remain unclear.

  4. The impact of high-dose vitamin C on blood glucose testing in ¹⁸F-FDG PET imaging.

    Science.gov (United States)

    Bahr, Rebekah L; Wilson, Don C

    2015-03-01

    Complementary and alternative therapies in addition to standard oncology protocols are commonly sought by cancer patients; however, few patients disclose their complementary treatments to their cancer care team. A lack of communication may result in unforeseen side effects and the potential for some alternative therapies to interfere with or inhibit conventional treatment. High-dose vitamin C therapy, in particular, may lead to an inability to measure a patient's blood glucose level before (18)F-FDG injection for PET/CT scanning. We report a case of a 52-y-old woman referred for (18)F-FDG PET/CT to evaluate the extent of recurrent colorectal cancer. The PET/CT scan immediately followed a single intravenous dose of 25 g of ascorbic acid from her naturopath. A glucometer that applies the glucose oxidase method for measuring fasting blood glucose was used, for which high doses of vitamin C are listed as a contraindication. The high concentration of ascorbic acid in the patient's blood sample interfered with the chemical reaction on the glucose strip, and therefore no blood glucose measurement could be attained. With more patients receiving alternative and complementary cancer therapies, it is important to know what the implications of orthomolecular therapy might be on routine blood glucose testing for (18)F-FDG PET scans. (18)F-FDG is in direct competition with glucose; therefore, elevated blood glucose levels will cause a decrease in (18)F-FDG absorption and may lead to a false-negative scan. PMID:25104819

  5. Blood glucose meter with biochemical analyzer blood glucose than on analysis%血糖仪与生化分析仪测定血糖的比对分析

    Institute of Scientific and Technical Information of China (English)

    秦亚军; 张保龙; 杨笑琼

    2013-01-01

      目的:探讨血糖仪与生化分析仪测定血糖的比对情况,为合理选择血糖检测方法提供参考。方法:选择2009年2月~2012年8月在我院门诊住院患者糖尿病人员共120例,上肢肘静脉和手指末端分别采血进行生化分析仪与血糖仪检测。结果:经过检测,生化分析仪检测的血糖值为(6.30±0.22)mmol/L,血糖仪检测的血糖值为(6.25±1.89)mmol/L,两种方法检测值对比无明显差异(P>0.05)。但是血糖仪检测的重复性不强,导致s值比较大。结论:血糖仪在糖尿病患者的血糖监测中有很大的局限性,在临床中要将血糖仪的监测和医院血糖检测结合使用,才能达到良好的血糖控制目的。%Objective:To investigate the blood glucose meter and biochemical analyzer than on blood sugar, and provide a reference for the reasonable choice of blood glucose testing method. Methods:From February 2009 to August 2012, a total of 120 cases of staff in our hospital hospitalized patients with diabetes, venous and finger blood samples were collected at the end of the upper limb elbow biochemical analyzer and blood glucose meter testing. Results:After testing, the the biochemical analyzer blood sugar value of (6.30± 0.22)mmol/L, blood glucose meter testing blood sugar value of (6.25±1.89)mmol/L, two methods for detecting the value of contrast was no significant difference(P>0.05). However, the reproducibility of the blood glucose meter detecting is not strong, resulting in the value of s is relatively large. Conclusion: The blood glucose meter glucose monitoring in diabetes has many limitations, combined To glucometer monitoring and hospital blood glucose testing in clinical use, in order to achieve good glycemic control purposes.

  6. Addition of sitagliptin or metformin to insulin monotherapy improves blood glucose control via different effects on insulin and glucagon secretion in hyperglycemic Japanese patients with type 2 diabetes.

    Science.gov (United States)

    Otsuka, Yuichiro; Yamaguchi, Suguru; Furukawa, Asami; Kosuda, Minami; Nakazaki, Mitsuhiro; Ishihara, Hisamitsu

    2015-01-01

    This study aimed to explore the effects of the dipeptidyl peptidase-4 inhibitor sitagliptin and the biguanide metformin on the secretion of insulin and glucagon, as well as incretin levels, in Japanese subjects with type 2 diabetes mellitus poorly controlled with insulin monotherapy. This was a single-center, randomized, open-label, parallel group study, enrolling 25 subjects. Eleven patients (hemoglobin A1c [HbA1c] 8.40 ± 0.96%) and 10 patients (8.10 ± 0.54%) on insulin monotherapy completed 12-week treatment with sitagliptin (50 mg) and metformin (750 mg), respectively. Before and after treatment, each subject underwent a meal tolerance test. The plasma glucose, glucagon-like peptide-1 (GLP-1), glucose-dependent insulinotropic polypeptide (GIP), C-peptide, and glucagon responses to a meal challenge were measured. HbA1c reductions were similar in patients treated with sitagliptin (0.76 ± 0.18%) and metformin (0.77 ± 0.17%). In the sitagliptin group, glucose excursion during a meal tolerance test was reduced and accompanied by elevations in active GLP-1 and active GIP concentrations. C-peptide levels were unaltered despite reduced glucose responses, while glucagon responses were significantly suppressed (-7.93 ± 1.95% of baseline). In the metformin group, glucose excursion and incretin responses were unaltered. C-peptide levels were slightly increased but glucagon responses were unchanged. Our data indicate that sitagliptin and metformin exert different effects on islet hormone secretion in Japanese type 2 diabetic patients on insulin monotherapy. A glucagon suppressing effect of sitagliptin could be one of the factors improving blood glucose control in patients inadequately controlled with insulin therapy. PMID:25328079

  7. Design of a prospective clinical study on the agreement between the Continuous GlucoseMonitor, a novel device for CONTinuous ASSessment of blood GLUcose levels, and the RAPIDLab® 1265 blood gas analyser: The CONTASSGLU study

    Directory of Open Access Journals (Sweden)

    Zimmermann Johannes B

    2012-09-01

    Full Text Available Abstract Background Although a device is needed to continuously measure blood glucose levels within an intensive care setting, and several large-scale prospective studies have shown that patients might benefit from intensive insulin, potassium, or glucose therapy during intensive care, no devices are currently available to continuously assess blood glucose levels in critically ill patients. We conceived the study described here to evaluate the clinical use of the Continuous Glucose Monitor (CGM performed via a central vein, and to determine the impact of phenomena, such as drift and shift, on the agreement between the CGM and a RAPIDLab® 1265 blood gas analyser (BGA. Methods/design In the CONTinuous ASSessment of blood GLUcose (CONTASSGLU study, up to 130 patients under intensive care will be fitted with the CGM, an ex vivo device that continuously measures blood glucose and lactate levels. Readings from the device taken 8 h after initial placement and calibration will be compared with values measured by a BGA. For this study, we chose the BGA as it is an established standard point-of-care device, instead of the devices used in certified central laboratories. Nevertheless, we will also independently compare the results from the point-of-care BGA with those determined by a central laboratory-based device. Blood samples will be collected from each patient from the same site in which the CGM will measure blood glucose. Consequently, each participant will serve as their own control, and no randomisation is necessary. The 95% limits of agreement and the corresponding confidence intervals will be calculated and compared with a prespecified clinically acceptable relative difference of 20%. Discussion Several attempts have been made to develop a device to continuously measure blood glucose levels within an intensive care setting or to use the devices that were originally designed for diabetes management, as several of these devices are already

  8. Alanine Aminotransferase Is Associated with an Adverse Nocturnal Blood Glucose Profile in Individuals with Normal Glucose Regulation

    OpenAIRE

    Zhou, Jian; Mo, Yifei; Li, Hong; Ran, Xingwu; Yang, Wenying; LI Qiang; Peng, Yongde; Li, Yanbing; Gao, Xin; Luan, Xiaojun; Wang, Weiqing; Jia, Weiping

    2013-01-01

    Objective Although the association between alanine aminotransferase (ALT) levels and risk of type 2 diabetes is well-studied, the effects of slightly increased ALT levels within the normal range on the temporal normal glucose profile remains poorly understood. Methods A total of 322 Chinese subjects without impaired glucose tolerance or previous diagnoses of diabetes were recruited for study from 10 hospitals in urban areas across China. All subjects wore a continuous glucose monitoring (CGM)...

  9. Evaluation of Glucose-6-Phosphate Dehydrogenase stability in stored blood samples.

    Science.gov (United States)

    Jalil, Norunaluwar; Azma, Raja Zahratul; Mohamed, Emida; Ithnin, Azlin; Alauddin, Hafiza; Baya, Siti Noor; Othman, Ainoon

    2016-01-01

    Glucose-6-Phosphate Dehydrogenase (G6PD) deficiency is the commonest cause of neonatal jaundice in Malaysia. Recently, OSMMR2000-D G6PD Assay Kit has been introduced to quantitate the level of G6PD activity in newborns delivered in Universiti Kebangsaan Malaysia Medical Centre (UKMMC). As duration of sample storage prior to analysis is one of the matters of concern, this study was conducted to identify the stability of G6PD enzyme during storage. A total of 188 cord blood samples from normal term newborns delivered at UKMMC were selected for this study. The cord bloods samples were collected in ethylene-diamine-tetra-acetic acid (EDTA) tubes and refrigerated at 2-8 °C. In addition, 32 out of 188 cord blood samples were spotted on chromatography paper, air-dried and stored at room temperature. G6PD enzyme activities were measured daily for 7 days using the OSMMR2000-D G6PD Assay Kit on both the EDTA blood and dried blood samples. The mean value for G6PD activity was compared between days of analysis using Student Paired T-Test. In this study, 172 out of 188 cord blood samples showed normal enzyme levels while 16 had levels corresponding to severe enzyme deficiency. The daily mean G6PD activity for EDTA blood samples of newborns with normal G6PD activity showed a significant drop on the fourth day of storage (p deficient G6PD activity, significant drop was seen on third day of storage (p = 0.002). Analysis of dried cord blood showed a significant reduction in enzyme activity as early as the second day of storage (p = 0.001). It was also noted that mean G6PD activity for spotted blood samples were lower compared to those in EDTA tubes for all days (p = 0.001). Thus, EDTA blood samples stored at 2-8 °C appeared to have better stability in terms of their G6PD enzyme level as compared to dried blood samples on filter paper, giving a storage time of up to 3 days. PMID:27103895

  10. Diabetes Technology: Markers, Monitoring, Assessment, and Control of Blood Glucose Fluctuations in Diabetes

    Directory of Open Access Journals (Sweden)

    Boris P. Kovatchev

    2012-01-01

    Full Text Available People with diabetes face a life-long optimization problem: to maintain strict glycemic control without increasing their risk for hypoglycemia. Since the discovery of insulin in 1921, the external regulation of diabetes by engineering means has became a hallmark of this optimization. Diabetes technology has progressed remarkably over the past 50 years—a progress that includes the development of markers for diabetes control, sophisticated monitoring techniques, mathematical models, assessment procedures, and control algorithms. Continuous glucose monitoring (CGM was introduced in 1999 and has evolved from means for retroactive review of blood glucose profiles to versatile reliable devices, which monitor the course of glucose fluctuations in real time and provide interactive feedback to the patient. Technology integrating CGM with insulin pumps is now available, opening the field for automated closed-loop control, known as the artificial pancreas. Following a number of in-clinic trials, the quest for a wearable ambulatory artificial pancreas is under way, with a first prototype tested in outpatient setting during the past year. This paper discusses key milestones of diabetes technology development, focusing on the progress in the past 10 years and on the artificial pancreas—still not a cure, but arguably the most promising treatment of diabetes to date.

  11. Effect of Syzygium Aromaticum (CLOVE) Extract on Blood Glucose Level in Streptozotocin induced Diabetic Rats

    International Nuclear Information System (INIS)

    Objective: To evaluate the glucose lowering effect of 50% ethanol extract of Syzygium aromaticum in comparison with that of standard insulin in streptozotocin induced diabetic rats. Study Design: Randomized control trial. Place and Duration of Study: National Institute of Health Islamabad. Jul 2011- Dec 2011 Material and Methods: It was carried out on 48 adult rats of Sprague dawley specie. Rats were equally divided into 6 groups (I-VI). Group - I served as control. Diabetes was induced by giving single intraperitoneal injection of STZ in Group II to VI. Group-II served as diabetic control, while groups III, IV, V and VI served as experimental groups. Group III, IV and V rats received 50% ethanol extract of Syzygium aromaticum at a dose of 250, 500 and 750 mg/kg body weight respectively for sixty days. Group VI (standard) received humulin insulin 70/30 at dose of 0.6 units<-kg body weight subcutaneously bid for sixty days. Fasting blood samples were taken at zero day, 15 day, 30 day and 60 day after giving injection STZ. Although Syzygium aromaticum with the doses of 250, 500 and 750 mg/kg body weight and insulin reduced the level of glucose in rats but on comparison Syzygium aromaticum 750 mg=kg dose reduced glucose more effectively than 250 and 500 mg/kg dose. While in group III, IV subjects, blood glucose levels remained above normal level. In group VI receiving insulin the level of this parameter remained almost closer to group IV rats. On studying the weight of the animals after receiving STZ there was initial reduction in the weight of all the experimental groups but after receiving the extract of plant improvement was seen and the weight of group V getting 750 mg=kg/body weight of Syzygium aromaticum became almost closer to the weight of control group. Conclusion: Syzygium aromaticum extract has glucose lowering effect in STZ induced diabetic rats and this effect is dose related and the dose of 750 mg/kg body weight has produced maximum effect. (author)

  12. Effects of Cinnamomum zeylanicum (Ceylon cinnamon on blood glucose and lipids in a diabetic and healthy rat model

    Directory of Open Access Journals (Sweden)

    Priyanga Ranasinghe

    2012-01-01

    Full Text Available Objectives: To evaluate short- and long-term effects of Cinnamomum zeylanicum on food consumption, body weight, glycemic control, and lipids in healthy and diabetes-induced rats. Materials and Methods: The study was conducted in two phases (Phase I and Phase II, using Sprague-Dawley rats in four groups. Phase I evaluated acute effects on fasting blood glucose (FBG (Groups 1 and 2 and on post-oral glucose (Groups 3 and 4 blood glucose. Groups 1 and 3 received distilled-water and Groups 2 and 4 received cinnamon-extracts. Phase II evaluated effects on food consumption, body weight, blood glucose, and lipids over 1 month. Group A (n = 8, distilled-water and Group B (n = 8, cinnamon-extracts were healthy rats, while Group C (n = 5, distilled-water and Group D (n = 5, cinnamon-extracts were diabetes-induced rats. Serum lipid profile and HbA1c were measured on D-0 and D-30. FBG, 2-h post-prandial blood glucose, body weight, and food consumption were measured on every fifth day. Results: Phase I: There was no significant difference in serial blood glucose values in cinnamon-treated group from time 0 (P > 0.05. Following oral glucose, the cinnamon group demonstrated a faster decline in blood glucose compared to controls (P < 0.05. Phase II: Between D0 and D30, the difference in food consumption was shown only in diabetes-induced rats (P < 0.001. Similarly, the significant difference following cinnamon-extracts in FBG and 2-h post-prandial blood glucose from D0 to D30 was shown only in diabetes-induced rats. In cinnamon-extracts administered groups, total and LDL cholesterol levels were lower on D30 in both healthy and diabetes-induced animals (P < 0.001. Conclusions: C. zeylanicum lowered blood glucose, reduced food intake, and improved lipid parameters in diabetes-induced rats.

  13. Effect of Cnidoscolus aconitifolius leaf extract on the blood glucose and insulin levels of inbred type 2 diabetic mice.

    Science.gov (United States)

    Oladeinde, F O; Kinyua, A M; Laditan, A A; Michelin, R; Bryant, J L; Denaro, F; Makinde, J M; Williams, A L; Kennedy, A P; Bronner, Y

    2007-01-01

    The effects of Cnidoscolus aconitifolius (CA) leaf extract and chlorpropamide on blood glucose and insulin levels in the inbred type 2 diabetic mice are reported. After treatment with CA, the glucose levels were measured at 0 and 2-hour intervals in experimental groups and controls. Group I received no treatment and served as control; Group II was the reference and it received chlorpropamide; Groups I-III were moderately diabetic, 100-300 mg/dL blood glucose levels while Group IV were severely diabetic (> 300 mg/dL). Groups III and IV received CA and served as test groups. There was no significant difference between the blood glucose levels at 0 and 2 hours for the control group, (P>0.23) but there were statistically significant differences for Group II (P<0.0002); Group III (P<0.002) and Group IV (P<0.0001). For moderately diabetic mice, CA and chlorpropamide decreased the glucose levels by 25.6% and 16.3% respectively while for the severely diabetic mice CA decreased the blood glucose by 43.7%. It is proposed that CA has an insulinogenic property that possibly stimulated dormant beta-cells to secrete insulin. The histopathology of several organs in the treated animals was found to differ from the expected. The islets of Langerhans for example were found to be preserved in the time frame examined. Also the liver and kidney were found to display milder pathology in the treated groups. PMID:17531147

  14. Alteration of blood glucose levels in the rat following exposure to hyperbaric oxygen.

    Science.gov (United States)

    Eynan, Mirit; Mullokandov, Michael; Krinsky, Nitzan; Biram, Adi; Arieli, Yehuda

    2015-09-01

    Findings regarding blood glucose level (BGL) on exposure to hyperbaric oxygen (HBO) are contradictory. We investigated the influence of HBO on BGL, and of BGL on latency to central nervous system oxygen toxicity (CNS-OT). The study was conducted on five groups of rats: Group 1, exposure to oxygen at 2.5 atmospheres absolute (ATA), 90 min/day for 7 days; Group 2, exposure to oxygen once a week from 2 to 6 ATA in increments of 1 ATA/wk, for a period of time calculated as 60% of the latency to CNS-OT (no convulsions); Group 3, exposure to 6 ATA breathing a gas mixture with a pO2 of 0.21; Group 4, received 10 U/kg insulin to induce hypoglycemia before exposure to HBO; Group 5, received 33% glucose to induce hyperglycemia before exposure to HBO. Blood samples were drawn before and after exposures for measurement of BGL. No change was observed in BGL after exposure to oxygen at 2.5 ATA, 90 min/day for 7 days. BGL was significantly elevated after exposure to oxygen at 6 ATA until the appearance of convulsions, and following exposure to 4, 5, and 6 ATA without convulsions (P HBO exposure on elevation of BGL, starting at 4 ATA. This implies that BGL may serve as a marker for the generation of CNS-OT. PMID:26183474

  15. The management of blood glucose in ICU%ICU血糖监测和管理

    Institute of Scientific and Technical Information of China (English)

    钱娟; 王莹

    2012-01-01

    Hyper glycemia and hypoglycemia are associated with poor outcome of critically ill patients.No consistent evidence shows that intensive insulin strategy improves health outcomes in hospitalized patients.Because of its potentially harmful and life-threatening consequences,hypoglycemia represents the main limit to the development of a tight blood glucose control strategy in critical illness.Hypoglycemia-related neurological signs may be masked.The occurrence of hypoglycemia in critical illness,especially severe hypoglycemia,is associated with a poor prognosis.So it is necessary to closely detect glycemic variability and control the blood glucose in proper level.%ICU患儿出现高血糖和低血糖均与不良预后相关.在应激性高血糖管理中,目前并不提倡“严格血糖控制策略”,以避免低血糖等不良事件发生.在危重病患儿中低血糖相关的神经系统症状往往被掩盖,严重低血糖与不良预后、高病死率相关.因此ICU患儿密切监测血糖尤为重要,及时发现血糖异常变化予以正确处理.

  16. EFFECT OF REGULAR GARLIC INGESTION ON BODY WEIGHT AND BLOOD GLUCOSE: A CASE STUDY IN MICE

    Directory of Open Access Journals (Sweden)

    F.T. Djankpa, A. Osonuga*, J. Ekpale, C.E. Quaye, P. Otoo, O.A. Osonuga and S.K. Amoah

    2012-05-01

    Full Text Available Garlic a perennial erect plant is known to have sulphur-containing compounds that act on the hypothalamus increasing the sensitivity of the hypothalamus to leptin which alters the set point at which satiety is reached causing an organism to eat less. Nine mice (six of which were obese were used in this study and grouped into three. Groups A and B were made of 3 obese mice each whereas group C consisted of 3 non-obese mice. For group A and group C mice, 20 ml aqueous garlic extract was added to their feed daily whereas no garlic was added to the feed of group B mice. The study was carried out over a period of 44 days. The weight and blood glucose was measured weekly and the average for each group was computed. Results indicated that Group A mice recorded a reduction in mean body weight by 46.5% (p<0.05. Group B mice had significant increase in mean body weight by 46.2% (p<0.05. The blood glucose level dropped significantly by 18.5% (p<0.05 in group A mice. Garlic had weight loss and hypoglycemic effect in obese mice. These effects were absent in non-obese mice.

  17. A moderate elevation of blood glucose level increases the effectiveness of thermoradiotherapy in a rat tumor model I. relative contributions of glucose and heating to tumor acidification

    International Nuclear Information System (INIS)

    Purpose: To establish dose-effect relationships for tumor acidification induced by heat and glucose as a basis for testing the value of adding glucose administration to combined heat and x-ray treatment at clinically achievable glucose and temperature levels. Methods and Materials: Rhabdomyosarcoma BA1112 was grown s.c. in the upper leg of 16-20-week-old Wag/Rij rats. Animals were given 2 consecutive 100-min periods of saline (S) or glucose (G) infusion, while keeping tumor temperature at 37 deg., 42 deg., or 43 deg. C for 1 or 2 periods, in various combinations, each involving 6 animals. Glucose was infused i.v. as a 20% solution at 2.4-3 g/kg/h. Tumors were heated using 2,450-MHz electromagnetic radiation, and tumor pH was measured using a 0.7 mm fiberoptic probe. Results: Mean overall baseline pH was 7.00 (SD 0.10). The change induced by G37G43 (i.e., glucose infusion for a full 200 min, first 100 min at 37 deg. C, final 100 min at 43 deg. C) was -0.48±0.03 (SEM) pH units, and -0.17 ± 0.03 for S37S43. The effect of G37G42 was -0.37±0.03 pH units, compared with -0.08±0.02 for S37S42 and -0.28±0.04 for glucose alone (G37G37). Glucose was less effective when given after or fully parallel to heating: -0.21±0.02 pH units for S43G37 and -0.37±0.02 for G43G43. Conclusion: The glucose-induced tumor pH drop is much more pronounced than that induced by heat, both of which are dose dependent. The effects of glucose and heat seem additive if heating is started when glucose-induced acidification has reached its plateau level, but the overall effect is diminished if administration is fully simultaneous or in reversed order. Schedule G37G43 is optimal with respect to tumor acidification. Its predicted superiority in thermoradiotherapy as compared with S37S42, S37S43, and G37G42 treatment regimens was confirmed in a subsequent experimental tumor control study

  18. Impact of admission blood glucose level on outcomes in community-acquired pneumonia in older adults

    Directory of Open Access Journals (Sweden)

    Bhattacharya RK

    2013-05-01

    Full Text Available Rajib K Bhattacharya, Jonathan D Mahnken, Sally K RiglerUniversity of Kansas School of Medicine, Kansas City, KS, USABackground: Community-acquired pneumonia (CAP is a common cause of morbidity and mortality in older adults. Although diabetes mellitus is a risk factor for pneumonia, the clinical impact of blood glucose level at the time of admission is not clear. Our goal was to examine the association between admission hyperglycemia and subsequent mortality, length of stay, and readmission outcomes in older adults with CAP.Methods: A retrospective observational study was conducted using hospital data for community-acquired pneumonia admissions in 857 persons from January 1, 2008 to December 31, 2010. We examined the effects of admission glucose level on mortality, length of stay, and 30 day readmission, adjusted for demographic factors and comorbidity.Results: The mean age of the sample was 64 years, and 51% of the subjects were female. Inpatient mortality occurred in 4.6% and the median length of stay was 5 days (interquartile range 3–9 days. Readmission within 30 days occurred in 17%. We found little impact of first glucose measures on in-hospital mortality (P = 0.94, length of stay (P = 0.95, and 30-day readmission (P = 0.56. Subjects 65 years and older trended towards higher in-hospital mortality. Older age, cancer, heart failure, and cirrhosis were associated with adverse outcomes.Conclusion: Glucose level upon admission for community-acquired pneumonia was not associated with adverse outcomes within 30 days in older adults.Keywords: community-acquired pneumonia, hyperglycemia, readmission rates, hospital mortality

  19. Bedside monitoring of subcutaneous interstitial glucose in type 1 diabetic subjects using microdialysis and infrared spectrometry with optimal correlation to blood glucose concentrations

    Science.gov (United States)

    Heise, H. Michael; Damm, Uwe; Kondepati, Venkata R.; Mader, J. K.; Ellmerer, M.

    2007-02-01

    Infrared spectroscopy has been successfully employed in multi-component assays for the study of various biomedical samples. Two areas have found particular interest, i.e. in-vitro analysis in the clinical laboratory and point-of-care applications. With regard to the latter field, in-vivo blood glucose monitoring is an important topic for improving glycemic control in critically ill patients with non-adequate blood glucose regulation, similar to the situation faced for diabetic patients. For such application, a continuously operated mid-infrared spectroscopic system in combination with a subcutaneously implanted microdialysis probe and coupled by micro-fluidics has been developed. Using the dialysis process, the interstitial fluid matrix can be significantly simplified, since high molecular mass compounds such as proteins are separated. However, the micro-dialysis recovery rate is variable over time, so that a simultaneous determination of this parameter was implemented using the losses of an acetate marker from the perfusate across the dialysis membrane. Clinical measurements were carried out on type 1 diabetic subjects, with experiments lasting up to 28 hours. The concentrations of glucose, acetate and other components in the dialysates from interstitial body fluids were investigated. Two different multivariate calibration strategies, i.e. partial least squares (PLS) and classical least squares (CLS) regressions were applied. The results led to excellent correlation of the subcutaneous interstitial concentrations with those of laboratory blood glucose readings. Clarke-Error-Grid evaluations were employed for assessing the clinical applicability of the method.

  20. A paper disk equipped with graphene/polyaniline/Au nanoparticles/glucose oxidase biocomposite modified screen-printed electrode: toward whole blood glucose determination.

    Science.gov (United States)

    Kong, Fen-Ying; Gu, Sai-Xi; Li, Wei-Wei; Chen, Ting-Ting; Xu, Qin; Wang, Wei

    2014-06-15

    In this work, a convenient, fast, low cost, small sample volume and in situ detection of glucose in human whole blood has been developed by using a disposable screen-printed carbon electrode (SPCE) coupled with a paper disk. To perform the assay, the SPCE was modified with graphene/polyaniline/Au nanoparticles/glucose oxidase (Gr/PANI/AuNPs/GOD) biocomposite and then covered by a paper disk impregnated with the sample. After introducing PBS on the paper disk, the electrochemical measurement was carried out. The assay was based on measuring the current decrease of flavin adenine dinucleotide (FAD) in GOD provoked by the enzyme-substrate reaction using differential pulse voltammetry (DPV). The analytical performance was comparable to conventional methods, and covered the full range of clinically relevant concentrations of glucose in whole blood. This new paper-based electrochemical glucose sensor shows promise in applying point-of-care (POC) device in whole blood tests, and particularly being appropriate for use in the developing world and in resource-limited settings. PMID:24469540

  1. Analysis of fasting blood glucose and glucose tolerance in 1 157 subjects%1157例体检者空腹血糖及糖耐量分析

    Institute of Scientific and Technical Information of China (English)

    王进

    2012-01-01

    Objective To analyze the fasting blood glucose(FBG) and glucose tolerance in 1 157 subjects accepting health examination to understand level and metabolism of blood glucose of local residents. Methods Adopting the method of population proportional sampling(PPS) , 1 157 subjects of all residents accepting health examination were randomly selected and divided into three groups according to economic conditions for the detection of FBG, among which 926 cases were detected for glucose tolerance by determination of blood glucose level 2 hours after oral intaking of 75 g glucose. Results 198 cases with high level of blood glucose and 117 cases with impaired glucose tolerance, accounting for 12. 63% , were demonstrated, and the prevalence of diabetes mellitus was 4. 86%. Conclusion The situation and prevalence of diabetes mellitus was serious in this region. Prevention of diabetes mellitus should be carried out from unban with better economic condition to other regions until the whole region.%目的 对1 157例体检者空腹血糖及糖耐量分析,掌握该区居民的血糖及其代谢情况.方法 采用人口成比例抽样(PPS)的方法,按经济条件分成3个层次,随机抽取1 157例研究对象采用葡萄糖氧化酶法测定空腹血糖,其中926例口服75 g无水葡萄糖2 h后测量血糖.结果 共计检出高血糖患者198例,检出糖耐量受损者117例,占12.63%,糖尿病患病率则为4.86%.结论 该区糖尿病患者及潜在者形势严峻,该区当前糖尿病防治应以经济较好的市区为重点向开发区辐射直至全区.

  2. Evaluation of blood glucose and thyroid function in Sudanese diabetic patients

    International Nuclear Information System (INIS)

    This study composes of two parts. The first one is a survey of thyroid abnormalities, and the second one is experiment to estimate the level of thyroid hormones (T4, T3, TSH) among diabetic population and the relationship between the level of glucose, thyroid hormones and lipid profile (TC, LDL, TG, HDL) and comparison of the results with non diabetic group. The survey part of the study to determine the thyroid abnormalities, hypothyroidism or hyperthyroidism clinical or subclinical. Also the study group was divided in to two groups according to insulin requirement. Type I is insulin-dependent diabetes mellitus and type II is non insulin-dependent diabetes mellitus. The study subjects selected for this study consist of one hundred Sudanese diabetic patients, they had mean age of 46.51±10.672 years, a mean height of 162.06±10.77 cm and a mean weight of 73.47±14.91 kg. Fifty healthy non-diabetic people without endocrine disease were chosen as controls. Glucose, and thyroid hormones, thyroxine and triiodothyronine (total T4 and T3) and thyroid stimulating hormone (TSH) were measured. In addition hemoglobin (Hb), total cholesterol (TC), triglyceride (TG), high-density lipoproteins (HDL) were also measured in both groups. Low-density lipoprotein (LDL) was calculated for each sample. Physical examinations such as height, weight, and history of diabetes, family history, treatment were recorded in both groups. Determination of serum hormones concentration was carried out using highly sensitive RIA technique. While determination of blood glucose, hemoglobin, and lipid profile was carried out using enzymatic colorimetric method. The results of this study showed that: 13 patients of the population screened had thyroid disease. The commonest diagnosis was sub clinical hyperthyroidism (6%), followed by sub clinical hypothyroidism (5%) and hyperthyroidism (2%). Female patients with diabetes had the highest annual risk of developing thyroid disease but all patient groups had a

  3. Effect of Punica granatum Linn. (flowers) on blood glucose level in normal and alloxan-induced diabetic rats.

    Science.gov (United States)

    Jafri, M A; Aslam, M; Javed, K; Singh, S

    2000-06-01

    'Gulnar farsi', male abortive flowers of Punica granatum L., are used for the treatment of diabetes mellitus in Unani medicine. Oral administration of its aqueous-ethanolic (50%, v/v) extract led to significant blood glucose lowering effect in normal, glucose-fed hyperglycaemic and alloxan-induced diabetic rats. This effect of the extract was maximum at 400 mg/kg, b.w. PMID:10837992

  4. Effects of telephone follow-up on blood glucose levels and postpartum screening in mothers with Gestational Diabetes Mellitus

    OpenAIRE

    Khorshidi Roozbahani, Rezvan; Geranmayeh, Mehrnaz; Hantoushzadeh, Sedigheh; Mehran, Abbas

    2015-01-01

    Background: Gestational diabetes mellitus (GDM) is a form of diabetes that occurs in pregnancy. GDM, defined as glucose intolerance, first diagnosed or initiated during pregnancy affects 1-14% of pregnancies based on various studies. Screening and early diagnosis and appropriate glycemic control can improve prenatal outcomes. Telephone follow-up seems to be a reasonable way for pregnant women follow-up. The present study evaluated the effects of telephone follow-up on blood glucose level duri...

  5. Effect of commercial rye whole-meal bread on postprandial blood glucose and gastric emptying in healthy subjects

    OpenAIRE

    Darwich Gassan; Björgell Ola; Lindstedt Sandra; Jönsson Jenny; Hlebowicz Joanna; Almér Lars-Olof

    2009-01-01

    Abstract Background The intake of dietary fibre has been shown to reduce the risk of developing diabetes mellitus. The aim of this study was to compare the effects of commercial rye whole-meal bread containing whole kernels and white wheat bread on the rate of gastric emptying and postprandial glucose response in healthy subjects. Methods Ten healthy subjects took part in a blinded crossover trial. Blood glucose level and gastric emptying rate (GER) were determined after the ingestion of 150 ...

  6. Combining insulins for optimal blood glucose control in type 1 and 2 diabetes: Focus on insulin glulisine

    OpenAIRE

    Ulrich, Heather; Snyder, Benjamin; K Garg, Satish

    2007-01-01

    Normalization of blood glucose is essential for the prevention of diabetes mellitus (DM)-related microvascular and macrovascular complications. Despite substantial literature to support the benefits of glucose lowering and clear treatment targets, glycemic control remains suboptimal for most people with DM in the United States. Pharmacokinetic limitations of conventional insulins have been a barrier to achieving treatment targets secondary to adverse effects such as hypoglycemia and weight ga...

  7. Effects of the extract from roasted chicory (Cichorium intybus L.) root containing inulin-type fructans on blood glucose, lipid metabolism, and fecal properties.

    Science.gov (United States)

    Nishimura, Mie; Ohkawara, Tatsuya; Kanayama, Toshiyuki; Kitagawa, Kazuya; Nishimura, Hiroyuki; Nishihira, Jun

    2015-07-01

    The extract from roasted chicory (Cichorium intybus L.; jú jù) root (chicory root extract), which contains inulin-type fructans, has favorable effects including antihyperglycemic and antidyslipidemic effects and the improvement of bowel movement. In this study, we examined the effects of chicory root extract on blood glucose, lipid metabolism, and fecal properties in 47 healthy adult participants in a randomized, double-blind, placebo-controlled study. The participants were divided into a test group that drank chicory root extract and a placebo group that drank nonchicory root extract (ingesting 300 mL daily for 4 weeks). We performed hematological examinations and body composition measurements, and administered a visual analog scale (VAS) questionnaire for fecal properties at the baseline (Week 0) and after the intervention (Week 4) for the two groups. Although no significant differences in fasting plasma glucose or insulin were observed, hemoglobin A1c was found to decrease by ingesting chicory root extract. No intergroup differences in the levels of lipid metabolism parameters were observed. However, the level of adiponectin was significantly improved in the chicory root extract group when the baseline and postintervention values were compared. In addition, chicory root extract tends to improve the VAS score for fecal properties. These results suggest that chicory root extract could delay or prevent the early onset of diabetes mellitus and improve bowel movements. PMID:26151029

  8. In-situ monitoring of blood glucose level for dialysis machine by AAA-battery-size ATR Fourier spectroscopy

    Science.gov (United States)

    Hosono, Satsuki; Sato, Shun; Ishida, Akane; Suzuki, Yo; Inohara, Daichi; Nogo, Kosuke; Abeygunawardhana, Pradeep K.; Suzuki, Satoru; Nishiyama, Akira; Wada, Kenji; Ishimaru, Ichiro

    2015-07-01

    For blood glucose level measurement of dialysis machines, we proposed AAA-battery-size ATR (Attenuated total reflection) Fourier spectroscopy in middle infrared light region. The proposed one-shot Fourier spectroscopic imaging is a near-common path and spatial phase-shift interferometer with high time resolution. Because numerous number of spectral data that is 60 (= camera frame rare e.g. 60[Hz]) multiplied by pixel number could be obtained in 1[sec.], statistical-averaging improvement realize high-accurate spectral measurement. We evaluated the quantitative accuracy of our proposed method for measuring glucose concentration in near-infrared light region with liquid cells. We confirmed that absorbance at 1600[nm] had high correlations with glucose concentrations (correlation coefficient: 0.92). But to measure whole-blood, complex light phenomenon caused from red blood cells, that is scattering and multiple reflection or so, deteriorate spectral data. Thus, we also proposed the ultrasound-assisted spectroscopic imaging that traps particles at standing-wave node. Thus, if ATR prism is oscillated mechanically, anti-node area is generated around evanescent light field on prism surface. By elimination complex light phenomenon of red blood cells, glucose concentration in whole-blood will be quantify with high accuracy. In this report, we successfully trapped red blood cells in normal saline solution with ultrasonic standing wave (frequency: 2[MHz]).

  9. Improving Detection of Prediabetes in Children and Adults: Using Combinations of Blood Glucose Tests

    Directory of Open Access Journals (Sweden)

    Ike Solomon Okosun

    2015-11-01

    Full Text Available Aim: To determine combinations of blood glucose tests: oral glucose tolerance (OGT, fasting plasma glucose (FBG and hemoglobin A1C (HbA1C that are associated with highest diagnostic rates of prediabetes in non-diabetic American children and adults.Methods: The 2007-2008 U.S. National Health and Nutrition Examination Surveys data were used for this study. Overall and specific prevalence of prediabetes (defined using OGT+FPG, OGT+HbA1C, HbA1C+FPG and OGT+FPG+HbA1C tests were determined across age, race/ethnicity, sex and BMI categories.Results: FPG+HbA1C test was associated with significantly higher diagnostic rates of prediabetes across age, race/ethnicity and BMI. Estimates of overall prevalence of prediabetes using OGT+FPG, OGT+HbA1C, HbA1C+FPG and OGT+FPG+HbA1C tests were 20.3%, 24.2%, 33% and 34.3%, respectively. Compared to OGT+FPG, the use of HbA1C+FPG test in screening was associated with 44.8%, 135%, 38.6% and 35.9% increased prevalence of prediabetes in non-Hispanic White, non-Hispanic Black, Mexican-American and other racial/ethnic men, respectively. The corresponding values in women were 67.8%, 140%, 37.2% and 42.6%, respectively. Combined use of all blood glucose tests did not improve the overall and gender-specific prediabetes prevalence beyond what was observed using HbA1C+FPG test.Conclusions: HbA1C criteria were associated with higher diagnosis rates of prediabetes than FPG and OGT tests in non-diabetic American children and adults. Using a combination of HbA1C and FPG test in screening for prediabetes reduces intrinsic systematic bias in using just HbA1C testing and offers the benefits of each test. A well-defined HbA1C that takes into consideration race/ethnicity, gender, age and body mass index may improve detection of prediabetes in population and clinical settings.

  10. Influence of glutathione-s-transferase (GSTT1 and GSTM1 polymorphism on baseline micronuclei frequency in peripheral blood lymphocytes

    Directory of Open Access Journals (Sweden)

    Stošić Ivana

    2014-01-01

    Full Text Available We have analyzed impact of polymorphism in GSTT1 and GSTM1 genes on the micronuclei (MN frequency in peripheral blood lymphocytes (PBLs. A total 134 women from central Serbia were enrolled in the study. Polymorphisms of GST genes were genotyped by performing a multiplex polymerase chain reaction (PCR and cytokinesis block micronucleus (CBMN test was used to assess MN frequency. GSTT1 null and GSTM1 null genotype carriers had higher MN frequencies as compared to positive counterparts but without statistical significance. Carriers of dual GSTT1/GSTM1 null genotypes had significantly higher MN frequency than positive/positive, positive/null and null/positive. Smokers and women >45 years old with GSTT1 null genotype and GSTT1null/GSTM1null genotypes have statistically higher MN frequency than positive counterparts. Results suggest possible influence of dual null genotypes of GSTT1/GSTM1 on the baseline MN frequency, as well influence on the level of MN in smokers and in women age >45 years. GSTT1 null genotype may have the potential to influence the baseline MN frequency in PBLs of smokers, as well as in women age >45 years. [Projekat Ministarstva nauke Republike Srbije, br. 41010

  11. Investigation on the correlationship between plasma homocysteine and blood glucose, insulin levels in patients with type 2 diabetes mellitus

    International Nuclear Information System (INIS)

    Objective: To explore the correlationship between plasma homocysteine and blood glucose, insulin levels in patients with type 2 diabetes mellitus. Methods: Plasma homocysteine (with ELISA), blood glucose (with hexokinase method) and insulin (with RIA) levels were measured in 66 patients with type 2 diabetes mellitus as well as in 35 controls. Results: Plasma homocysteine levels in the diabetic patients (n=66) were significantly higher than those in controls (P<0.01), especially in those patients complicated with nephropathy (n=32). The homocysteine levels were positively correlated with those of blood glucose and insulin (r=0.3515, r=0.3486, both P<0.01). Conclusion: Plasma homocysteine is an independent risk factor for vascular diseases. The levels of plasma cysteine are significantly increased in patients with type 2 diabetes mellitus, especially in those complicated with nephropathy. Therefore, monitoring of plasma homocysteine level changes is clinically useful. (authors)

  12. Effect of whey on blood glucose and insulin responses to composite breakfast and lunch meals in type 2 diabetic subjects

    DEFF Research Database (Denmark)

    Frid, Anders H; Nilsson, Mikael; Holst, Jens Juul;

    2005-01-01

    breakfast and lunch meals were supplemented with whey on one day; whey was exchanged for lean ham and lactose on another day. Venous blood samples were drawn before and during 4 h after breakfast and 3 h after lunch for the measurement of blood glucose, serum insulin, glucose-dependent insulinotropic......BACKGROUND: Whey proteins have insulinotropic effects and reduce the postprandial glycemia in healthy subjects. The mechanism is not known, but insulinogenic amino acids and the incretin hormones seem to be involved. OBJECTIVE: The aim was to evaluate whether supplementation of meals with a high...... glycemic index (GI) with whey proteins may increase insulin secretion and improve blood glucose control in type 2 diabetic subjects. DESIGN: Fourteen diet-treated subjects with type 2 diabetes were served a high-GI breakfast (white bread) and subsequent high-GI lunch (mashed potatoes with meatballs). The...

  13. The use of Fourier-transform infrared spectroscopy for the quantitative determination of glucose concentration in whole blood.

    Science.gov (United States)

    Shen, Y C; Davies, A G; Linfleld, E H; Elsey, T S; Taday, P F; Arnone, D D

    2003-07-01

    Fourier-transform infrared transmission spectroscopy has been used for the determination of glucose concentration in whole blood samples from 28 patients. A 4-vector partial least-squares calibration model, using the spectral range 950-1200 cm(-1), yielded a standard-error-of-prediction of 0.59 mM for an independent test set. For blood samples from a single patient, we found that the glucose concentration was proportional to the difference between the values of the second derivative spectrum at 1082 cm(-1) and 1093 cm(-1). This indicates that spectroscopy at these two specific wavenumbers alone could be used to determine the glucose concentration in blood plasma samples from a single patient, with a prediction error of 0.95 mM. PMID:12884933

  14. Evaluation of OneTouch Verio(®), a new blood glucose self-monitoring system for patients with diabetes

    DEFF Research Database (Denmark)

    Littmann, Karin; Petersen, Eva; Pussinen, Christel;

    2013-01-01

    Introduction. Self-monitoring of blood glucose (SMBG) is important in diabetes management. Reliable and user-friendly instruments are essential. OneTouch Verio(®) is a new blood glucose concentration-measuring system designed to be used by patients with diabetes and healthcare professionals. The...... objective of the present study was to evaluate the analytical performance of the OneTouch Verio(®). Method. The OneTouch Verio(®) was evaluated by the Scandinavian evaluation of laboratory equipment for primary healthcare (SKUP) according to a protocol based on ISO 15197 and the American Diabetes...... routine method, imprecision and bias were calculated. User-friendliness was evaluated with a questionnaire. Results. Quality specifications for blood glucose concentration monitoring systems according to ISO 15197 were fulfilled. The mean coefficients of variation (CV%) of repeatability was 3.4% when...

  15. Effect of Blood Glucose Fluctuation on Some Trace Elements and Aldosterone Hormone among Type II Diabetic Patients with Metabolic Syndrome

    International Nuclear Information System (INIS)

    There is accumulating evidence determine that the metabolism of some trace elements is altered in diabetes mellitus (DM) type II. The current study aimed to evaluate the effect of serum blood glucose fluctuation during (Random, Fasting and Postprandial 2 hours state) on some trace elements such as Cadmium (Cd), Chromium (Cr), Manganese (Mn), Magnesium (Mg), Zinc (Zn), Copper (Cu), Sodium (Na), Potassium (K), and Aldosterone hormone in type II Diabetic patients associated with metabolic syndrome in comparison with healthy volunteers. The International Diabetes Federation (IFD) consensus the diagnosis of metabolic syndrome according to central obesity, lipid profile, blood glucose level and blood pressure. A significant change was observed in trace elements level (Cd, Cr, Mg, Mn, Zn, Cu, Na, and K) and Aldosterone hormone as a result of glucose fluctuation among type II diabetic patients.

  16. Glucose 6-phosphate dehydrogenase deficient subjects may be better "storers" than donors of red blood cells.

    Science.gov (United States)

    Tzounakas, Vassilis L; Kriebardis, Anastasios G; Georgatzakou, Hara T; Foudoulaki-Paparizos, Leontini E; Dzieciatkowska, Monika; Wither, Matthew J; Nemkov, Travis; Hansen, Kirk C; Papassideri, Issidora S; D'Alessandro, Angelo; Antonelou, Marianna H

    2016-07-01

    Storage of packed red blood cells (RBCs) is associated with progressive accumulation of lesions, mostly triggered by energy and oxidative stresses, which potentially compromise the effectiveness of the transfusion therapy. Concerns arise as to whether glucose 6-phosphate dehydrogenase deficient subjects (G6PD(-)), ~5% of the population in the Mediterranean area, should be accepted as routine donors in the light of the increased oxidative stress their RBCs suffer from. To address this question, we first performed morphology (scanning electron microscopy), physiology and omics (proteomics and metabolomics) analyses on stored RBCs from healthy or G6PD(-) donors. We then used an in vitro model of transfusion to simulate transfusion outcomes involving G6PD(-) donors or recipients, by reconstituting G6PD(-) stored or fresh blood with fresh or stored blood from healthy volunteers, respectively, at body temperature. We found that G6PD(-) cells store well in relation to energy, calcium and morphology related parameters, though at the expenses of a compromised anti-oxidant system. Additional stimuli, mimicking post-transfusion conditions (37°C, reconstitution with fresh healthy blood, incubation with oxidants) promoted hemolysis and oxidative lesions in stored G6PD(-) cells in comparison to controls. On the other hand, stored healthy RBC units showed better oxidative parameters and lower removal signaling when reconstituted with G6PD(-) fresh blood compared to control. Although the measured parameters of stored RBCs from the G6PD deficient donors appeared to be acceptable, the results from the in vitro model of transfusion suggest that G6PD(-) RBCs could be more susceptible to hemolysis and oxidative stresses post-transfusion. On the other hand, their chronic exposure to oxidative stress might make them good recipients, as they better tolerate exposure to oxidatively damaged long stored healthy RBCs. PMID:27094493

  17. Effect of Fasting Blood Glucose Level on Heart Rate Variability of Healthy Young Adults.

    Directory of Open Access Journals (Sweden)

    Mohamed Faisal Lutfi

    Full Text Available Previous studies reported increased risk of cardiac events in subjects with fasting blood glucose (FBG levels lower than the diagnostic threshold of diabetes mellitus. However, whether increased cardiac events in those with upper normal FBG is secondary to the shift of their cardiac sympathovagal balance towards sympathetic predominance is unknown.To assess the association between FBG levels and cardiac autonomic modulation (CAM in euglycaemic healthy subjects based on heart rate variability (HRV derived indices.The study enrolled 42 healthy young adults. Following sociodemographic and clinical assessment, blood samples were collected to measure FBG levels. Five minutes ECG recordings were performed to all participants to obtain frequency domain HRV measurements, namely the natural logarithm (Ln of total power (LnTP, very low frequency (LnVLF, low frequency (LnLF and high frequency (LnHF, low frequency/ high frequency ratio (LnLF/HF, normalized low frequency (LF Norm and high frequency (HF Norm.FBG levels correlated positively with LnHF (r = 0.33, P = 0.031 and HF Norm (r = 0.35, P = 0.025 and negatively with LF Norm (r = -0.35, P = 0.025 and LnLF/HF (r = -0.33, P = 0.035. LnHF and HF Norm were significantly decreased in subjects with the lower (4.00 (1.34 ms2/Hz and 33.12 (11.94 n.u compared to those with the upper FBG quartile (5.64 (1.63 ms2/Hz and 49.43 (17.73 n.u, P = 0.013 and 0.032 respectively. LF Norm and LnLF/HF were significantly increased in subjects with the lower (66.88 (11.94 n.u and 0.73 (0.53 compared to those with the higher FBG quartile (50.58 (17.83 n.u and 0.03 (0.79, P = 0.032 and 0.038 respectively.The present study is the first to demonstrate that rise of blood glucose concentration, within physiological range, is associated with higher parasympathetic, but lower sympathetic CAM. Further researches are needed to set out the glycemic threshold beyond which further increase in glucose level readjusts sympathovagal balance

  18. Effect of Fasting Blood Glucose Level on Heart Rate Variability of Healthy Young Adults

    Science.gov (United States)

    Lutfi, Mohamed Faisal; Elhakeem, Ramaze Farouke

    2016-01-01

    Background Previous studies reported increased risk of cardiac events in subjects with fasting blood glucose (FBG) levels lower than the diagnostic threshold of diabetes mellitus. However, whether increased cardiac events in those with upper normal FBG is secondary to the shift of their cardiac sympathovagal balance towards sympathetic predominance is unknown. Aims To assess the association between FBG levels and cardiac autonomic modulation (CAM) in euglycaemic healthy subjects based on heart rate variability (HRV) derived indices. Subjects and Methods The study enrolled 42 healthy young adults. Following sociodemographic and clinical assessment, blood samples were collected to measure FBG levels. Five minutes ECG recordings were performed to all participants to obtain frequency domain HRV measurements, namely the natural logarithm (Ln) of total power (LnTP), very low frequency (LnVLF), low frequency (LnLF) and high frequency (LnHF), low frequency/ high frequency ratio (LnLF/HF), normalized low frequency (LF Norm) and high frequency (HF Norm). Results FBG levels correlated positively with LnHF (r = 0.33, P = 0.031) and HF Norm (r = 0.35, P = 0.025) and negatively with LF Norm (r = -0.35, P = 0.025) and LnLF/HF (r = -0.33, P = 0.035). LnHF and HF Norm were significantly decreased in subjects with the lower (4.00 (1.34) ms2/Hz and 33.12 (11.94) n.u) compared to those with the upper FBG quartile (5.64 (1.63) ms2/Hz and 49.43 (17.73) n.u, P = 0.013 and 0.032 respectively). LF Norm and LnLF/HF were significantly increased in subjects with the lower (66.88 (11.94) n.u and 0.73 (0.53)) compared to those with the higher FBG quartile (50.58 (17.83) n.u and 0.03 (0.79), P = 0.032 and 0.038 respectively). Conclusion The present study is the first to demonstrate that rise of blood glucose concentration, within physiological range, is associated with higher parasympathetic, but lower sympathetic CAM. Further researches are needed to set out the glycemic threshold beyond which

  19. Effect of Full Correction Versus Partial Correction of Elevated Blood Glucose in the Emergency Department on Hospital Length of Stay.

    Science.gov (United States)

    Johnson-Clague, Michaela; DiLeo, Jessica; Katz, Michael D; Patanwala, Asad E

    2016-01-01

    There is limited information to guide the extent to which asymptomatic hyperglycemia needs to be corrected in patients presenting to the emergency department (ED) with unrelated complaints. The objective of this study was to compare full correction (FC) versus partial correction (PC) of elevated blood glucose in the ED on hospital length of stay. This was a retrospective cohort study conducted in an academic ED in the United States. Adult diabetic patients with hyperglycemia (blood glucose >200 mg/dL) in the ED who were treated with subcutaneous insulin were included. Patients were categorized based on the level of blood glucose control achieved within the first 24 hours from triage: (1) FC group for whom blood glucose hospital length of stay between groups. A total of 161 patients were included in this study (FC = 81, PC = 80). There was no significant difference between hospital length of stay in the FC [3 days (interquartile range, 1-5 days)] and PC [3 days (interquartile range, 2-6 days)] groups (P = 0.159). In the multivariate analysis, after adjusting for potential confounders, there was no significant association between level of correction and hospital length of stay (log-transformed) (coefficient 0.238; 95% confidence interval, -0.062 to 0.537; P = 0.119; R = 13%). The extent of glucose correction was not associated with a decrease in hospital length of stay in diabetic patients with hyperglycemia in the ED. PMID:25187094

  20. Postprandial blood glucose control in type 1 diabetes for carbohydrates with varying glycemic index foods.

    Science.gov (United States)

    Hashimoto, Shogo; Noguchi, Claudia Cecilia Yamamoto; Furutani, Eiko

    2014-01-01

    Treatment of type 1 diabetes consists of maintaining postprandial normoglycemia using the correct prandial insulin dose according to food intake. Nonetheless, it is hardly achieved in practice, which results in several diabetes-related complications. In this study we present a feedforward plus feedback blood glucose control system that considers the glycemic index of foods. It consists of a preprandial insulin bolus whose optimal bolus dose and timing are stated as a minimization problem, which is followed by a postprandial closed-loop control based on model predictive control. Simulation results show that, for a representative carbohydrate intake of 50 g, the present control system is able to maintain postprandial glycemia below 140 mg/dL while preventing postprandial hypoglycemia as well. PMID:25571074

  1. Study of the Effect of Garlic on Serum Lipids and Blood Glucose Levels in Type 2 Diabetic Patients

    Directory of Open Access Journals (Sweden)

    M Afkhami - Ardekani

    2005-04-01

    Full Text Available Introduction: Hyperlipidemia and diabetes are common risk factors for ischemic heart disease, which is the main cause of mortality in diabetic patients. Strict control of blood glucose and other risk factors in diabetics has led to prevention of complications. Garlic has received particular attention for control of blood glucose and decrease in blood lipid levels. At present, several studies have been carried out in order to prove advantages of garlic. Methods: In this study, effects of garsin (a derivative of garlic present in our country on serum lipids and blood glucose levels in diabetes mellitus type 2 patients was observed. Forty-five type 2 diabetics who had hyperlipidemia were selected. These patients were kept on treatment with 3 tablets of Garsin / day for 4 weeks. Serum lipids and blood glucose levels were measured prior to and at the end of treatment. Results: Relationship between sex and response to treatment in this study was meaningful, such that Gsarsin led to decrease in LDL-C and increase in HDL in females. Conclusion: Therefore, Garsin can be used as an adjunct to treatment in diabetes type 2 patients with hyperlipidemia.

  2. Blood glucose control in patients with severe sepsis and septic shock

    Institute of Scientific and Technical Information of China (English)

    Hiroyuki Hirasawa; Shigeto Oda; Masataka Nakamura

    2009-01-01

    The main pathophysiological feature of sepsis is the uncontrollable activation of both pro- and anti-inflammatory responses arising from the overwhelming production of mediators such as pro- and anti-inflammatory cytokines. Such an uncontrollable inflammatory response would cause many kinds of metabolic derangements.One such metabolic derangement is hyperglycemia.Accordingly, control of hyperglycemia in sepsis is considered to be a very effective therapeutic approach. However, despite the initial enthusiasm, recent studies reported that tight glycemic control with intensive insulin therapy failed to show a beneficial effect on mortality of patients with severe sepsis and septic shock. One of the main reasons for this disappointing result is the incidence of harmful hypoglycemia during intensive insulin therapy. Therefore, avoidance of hypoglycemia during intensive insulin therapy may be a key issue in effective tight glycemic control.It is generally accepted that glycemic control aimed at a blood glucose level of 80-100 mg/dL, as initially proposed by van den Berghe, seems to be too tight and that such a level of tight glycemic control puts septic patients at increased risk of hypoglycemia. Therefore,now many researchers suggest less strict glycemic control with a target blood glucose level of 140-180 mg/dL.Also specific targeting of glycemic control in diabetic patients should be considered. Since there is a significant correlation between success rate of glycemic control and the degree of hypercytokinemia in septic patients,some countermeasures to hypercytokinemia may be an important aspect of successful glycemic control. Thus,in future, use of an artificial pancreas to avoid hypoglycemia during insulin therapy, special consideration of septic diabetic patients, and control of hypercytokinemia should be considered for more effective glycemic control in patients with severe sepsis and septic shock.

  3. Effects of Flavonoids in Morus indica on Blood Lipids and Glucose in Hyperlipidemia-diabetic Rats

    Institute of Scientific and Technical Information of China (English)

    MA Dong-qing; JIANG Zheng-ju; XU Shi-qiang; YU Xing; HU Xia-min; PAN Hong-yan

    2012-01-01

    Objective To investigate the effect and possible mechanism of flavonoids extracted from Morus indica(FMI)on blood lipids and glucose.Methods The experimental hyperlipidemia-diabetic rats were induced by high-fat diet(HFD)and low dose of Streptozotocin(STZ).Flavonoids-treated rats were pretreated with FMI(50,100,and 200 mg/kg).The plasma,skeletal muscle,and livers were isolated for biochemical assays,HE staining,immunohistochemistry,and Western blotting analysis.Results The results showed that the body weight in flavonoidstreated(100 and 200 mg/kg)rats was reduced(P<0.05,0.01)compared to HFD-fed rats.FMI obviously reduced total cholesterol(P<0.01),triglycerides(P<0.05),and low-density lipoprotein cholesterol(P<0.05),increased high-density lipoprotein(P<0.05),and significantly decreased the atherosclerosis index(P<0.01);FMI(100 and 200 mg/kg)also down-regulated the elevation of blood glucose induced by STZ(P<0.05,0.01);At the meantime,FMI increased hepatic superoxide dismutase(SOD)activity and reduced hepatic malondialdehyde(MDA)content obviously.In addition,the results showed that the expression of hepatic CYP2E1 was markedly decreased while the expression of GLUT-4 in skeletal muscles was increased by FMI.Conclusion The above results demonstrate that the effect of FMI is related to its up-regulation of hepatic SOD activity,reduction of hepatic MDA content,down-regulation of hepatic CYP2E1 expression,and increase of GLUT-4 expression in skeletal muscle,which suggests that FMI may prevent or improve hyperlipidemia and hyperglycemia caused by an excessive HFD.

  4. Wine grape pomace flour improves blood pressure, fasting glucose and protein damage in humans: a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Inés Urquiaga

    2015-01-01

    Full Text Available BACKGROUND: The Mediterranean diet is a healthy diet with positive scientific evidence of preventing chronic diseases. Bioactive components support the healthy properties of the Mediterranean diet. Antioxidants and fiber, two components of the Mediterranean diet, are key functional nutrients for healthy eating and nutrition. Wine grape pomace is a rich source of these dietary constituents and may be beneficial for human health. Our hypothesis was that the intake of red wine grape pomace flour (WGPF prepared from red wine grapes (Cabernet Sauvignon variety reduced the metabolic syndrome in humans. To evaluate the effect of WGPF on components of metabolic syndrome we design a 16-week longitudinal intervention study. Thirty-eight males, 30-65 years of age, with at least one component of metabolic syndrome, were randomly assigned to either the intervention group (n = 25 or the control group (n = 13. At lunch, the intervention group was given 20 g of WGPF per day, which contained 10 g of dietary fiber, 822 mg of polyphenols and an antioxidant capacity of 7258 ORAC units. Both groups were asked to maintain their regular eating habits and lifestyles. Clinical evaluation, anthropometric measurements and biochemical blood analyses were done at the beginning and the end of the study. RESULTS: WGPF intake significantly decreased systolic and diastolic blood pressure as well as fasting glucose levels. Plasma γ-tocopherol and δ-tocopherol increased and carbonyl group in plasma protein decreased in WGPT group, significantly. No significant effect was observed for waist circumference, HDL cholesterol, triglycerides, total antioxidant capacity and vitamin C in and between groups. The group-dependent magnitude of the differences between the baseline and final postprandial insulin values and γ-tocopherol concentrations was statistically significant. CONCLUSIONS: The consumption of WGPF-rich in fiber and polyphenol antioxidants, as a food supplement in a

  5. The impact of brief high-intensity exercise on blood glucose levels

    Directory of Open Access Journals (Sweden)

    Adams OP

    2013-02-01

    Full Text Available O Peter AdamsFaculty of Medical Sciences, the University of the West Indies, Cave Hill Campus, St Michael, BarbadosBackground: Moderate-intensity exercise improves blood glucose (BG, but most people fail to achieve the required exercise volume. High-intensity exercise (HIE protocols vary. Maximal cycle ergometer sprint interval training typically requires only 2.5 minutes of HIE and a total training time commitment (including rest and warm up of 25 minutes per session. The effect of brief high-intensity exercise on blood glucose levels of people with and without diabetes is reviewed.Methods: HIE (≥80% maximal oxygen uptake, VO2max studies with ≤15 minutes HIE per session were reviewed.Results: Six studies of nondiabetics (51 males, 14 females requiring 7.5 to 20 minutes/week of HIE are reviewed. Two weeks of sprint interval training increased insulin sensitivity up to 3 days postintervention. Twelve weeks near maximal interval running (total exercise time 40 minutes/week improved BG to a similar extent as running at 65% VO2max for 150 minutes/week. Eight studies of diabetics (41 type 1 and 22 type 2 subjects were reviewed. Six were of a single exercise session with 44 seconds to 13 minutes of HIE, and the others were 2 and 7 weeks duration with 20 and 2 minutes/week HIE, respectively. With type 1 and 2 diabetes, BG was generally higher during and up to 2 hours after HIE compared to controls. With type 1 diabetics, BG decreased from midnight to 6 AM following HIE the previous morning. With type 2 diabetes, a single session improved postprandial BG for 24 hours, while a 2-week program reduced the average BG by 13% at 48 to 72 hours after exercise and also increased GLUT4 by 369%.Conclusion: Very brief HIE improves BG 1 to 3 days postexercise in both diabetics and nondiabetics. HIE is unlikely to cause hypoglycemia during and immediately after exercise. Larger and longer randomized studies are needed to determine the safety, acceptability, long

  6. Clinical significance of serum carbohydrate antigen 19-9 and its relationship with blood glucose in patients with type 2 diabetes

    Institute of Scientific and Technical Information of China (English)

    武秀玲

    2013-01-01

    Objective To study the relationship between serum carbohydrate antigen 19-9 (CA19-9) and blood glucose level in patients with type 2 diabetes (T2DM) .Methods Totally 784 T2DM patients and 197 healthy controls were enrolled in this study.Age,duration,body mass index (BMI) ,systolic blood pressure (SBP) ,diastolic blood pressure (DBP) ,levels of fasting blood glucose (FBG) ,postprandial blood glucose (PBG) ,hemoglobin A1c (HbA1c) ,total cholesterol (TC) ,triglyceride (TG) ,

  7. The Effect of Trans-Chalcone on Amylase Activity, Blood Glucose and Lipid Levels in Diabetic and Non Diabetic Rats

    OpenAIRE

    Najafian, M.; Ebrahim-Habibi, A.; P Yaghmaei; Parivar, K.; Larijani, B.

    2011-01-01

    Introduction & Objective: Alpha amylase is the most important decomposing enzyme in starch. Digestion and absorption of starch in the intestine can be prevented and also the blood sugar levels can be controlled by restrain and control of alpha amylase. The aim of this study was to evaluate the effect of trans-chalcone on amylase activity, blood glucose and lipid levels in diabetic and non diabetic rats. Materials & Methods: This experimental study was conducted in 1388 at Tehran Universit...

  8. Effect of Cucurbita ficifolia and Probiotic Yogurt Consumption on Blood Glucose, Lipid Profile, and Inflammatory Marker in Type 2 Diabetes

    OpenAIRE

    Azade Bayat; Fatemeh Azizi-Soleiman; Motahar Heidari-Beni; Awat Feizi; Bijan Iraj; Reza Ghiasvand; Gholamreza Askari

    2016-01-01

    Background: Control of blood sugar, hypertension, and dyslipidemia are key factors in diabetes management. Cucurbita ficifolia (pumpkin) is a vegetable which has been used traditionally as a remedy for diabetes in Iran. In addition, consumption of probiotics may have beneficial effects on people with Type 2 diabetes. The aim of this study was an investigation of the effects of C. ficifolia and probiotic yogurt consumption alone or at the same time on blood glucose and serum lipids in diabetic...

  9. Early and progressive impairment of spinal blood flow–glucose metabolism coupling in motor neuron degeneration of ALS model mice

    OpenAIRE

    Miyazaki, Kazunori; Masamoto, Kazuto; Morimoto, Nobutoshi; Kurata, Tomoko; Mimoto, Takahumi; Obata, Takayuki; Kanno, Iwao; Abe, Koji

    2011-01-01

    The exact mechanism of selective motor neuron death in amyotrophic lateral sclerosis (ALS) remains still unclear. In the present study, we performed in vivo capillary imaging, directly measured spinal blood flow (SBF) and glucose metabolism, and analyzed whether if a possible flow–metabolism coupling is disturbed in motor neuron degeneration of ALS model mice. In vivo capillary imaging showed progressive decrease of capillary diameter, capillary density, and red blood cell speed during the di...

  10. Reliable long-term continuous blood glucose monitoring for patients in critical care using microdialysis and infrared spectrometry

    Science.gov (United States)

    Heise, H. Michael; Damm, Uwe; Kondepati, Venkata R.

    2006-02-01

    For clinical research, in-vivo blood glucose monitoring is an ongoing important topic to improve glycemic control in patients with non-adequate blood glucose regulation. Critically ill patients received much interest, since the intensive insulin therapy treatment, as established for diabetics, reduces mortality significantly. Despite the existence of commercially available, mainly amperometric biosensors, continued interest is in infrared spectroscopic techniques for reagent-free glucose monitoring. For stable long-term operation, avoiding also sensor recalibration, a bed-side device coupled to a micro-dialysis probe was developed for quasi-continuous glucose monitoring. Multivariate calibration is required for glucose concentration prediction due to the complex composition of dialysates from interstitial body fluid. Measurements were carried out with different test persons, each experiment lasting for more than 8 hours. Owing to low dialysis recovery rates, glucose concentrations in the dialysates were between 0.83 and 4.44 mM. Standard errors of prediction (SEP) obtained with Partial Least Squares (PLS) calibration and different cross-validation strategies were mainly between 0.13 and 0.18 mM based on either full interval data or specially selected spectral variables.

  11. Antihypertensive medications and sexual function in women: Baseline data from the Systolic Blood Pressure Intervention Trial (SPRINT)

    Science.gov (United States)

    Thomas, Holly N.; Evans, Gregory W.; Berlowtiz, Dan R.; Chertow, Glenn M.; Conroy, Molly B.; Foy, Capri G.; Glasser, Stephen P.; Lewis, Cora E.; Riley, William T.; Russell, Laurie; Williams, Olubunmi; Hess, Rachel

    2016-01-01

    Objectives Hypertension is a risk factor for the development of cardiovascular and kidney disease, but treatment can substantially reduce risks. Many patients avoid antihypertensive medications due to fear of side effects. While associations between antihypertensives and sexual dysfunction in men have been documented, it remains unclear whether antihypertensives are associated with sexual dysfunction in women. We conducted a cross-sectional analysis of baseline data from women in the Systolic Blood Pressure Intervention Trial (SPRINT) to evaluate the relations among class of antihypertensive medication and the outcomes (a) sexual activity and (b) sexual function. Methods SPRINT enrolled individuals 50 and older with hypertension at high risk for cardiovascular disease. A subset of participants completed questionnaires regarding quality of life (QoL), including sexual function. Antihypertensive class was determined by medications taken at baseline. Results Of 690 women in the QoL subset of SPRINT, 183 (26.5%) were sexually active. There were no significant differences in sexual activity among women taking one or more antihypertensives and women not taking any. Women taking an angiotensin-converting enzyme inhibitor or angiotensin receptor blocker (ACEI/ARB) had higher odds of sexual activity [OR 1.66 (1.12-4.27), p=0.011]. Among sexually active women, the prevalence of sexual dysfunction was high (52.5%). No class of medication was associated with sexual dysfunction in the multivariable model. Conclusions ACEI/ARB use was associated with higher odds of sexual activity. While prevalence of sexual dysfunction was high, no single class of antihypertensive medication was associated with sexual dysfunction. PMID:27032074

  12. Hollow optical-fiber based infrared spectroscopy for measurement of blood glucose level by using multi-reflection prism.

    Science.gov (United States)

    Kino, Saiko; Omori, Suguru; Katagiri, Takashi; Matsuura, Yuji

    2016-02-01

    A mid-infrared attenuated total reflection (ATR) spectroscopy system employing hollow optical fibers and a trapezoidal multi-reflection ATR prism has been developed to measure blood glucose levels. Using a multi-reflection prism brought about higher sensitivity, and the flat and wide contact surface of the prism resulted in higher measurement reproducibility. An analysis of in vivo measurements of human inner lip mucosa revealed clear signatures of glucose in the difference spectra between ones taken during the fasting state and ones taken after ingestion of glucose solutions. A calibration plot based on the absorption peak at 1155 cm(-1) that originates from the pyranose ring structure of glucose gave measurement errors less than 20%. PMID:26977373

  13. Changes of hemoglobin content and glucose levels in the blood of Rattus norvegicus by water extracts of Azadirachta indica

    Institute of Scientific and Technical Information of China (English)

    Shori; Amal Bakr

    2012-01-01

    Presently,there is a growing interest in herbal remedies.Neem (Azadirachta indica) has been used in traditional medicine over centuries.In the present study,the effects of water extracts of Azadirachta indica seeds,stems,flowers and bark on the changes of hemoglobin content (Hb) and glucose levels in the blood of Rattus norvegicus were investigated.Different doses of A.indica water extracts of seeds,stems,flowers and bark were injected to the tested animals every 48 h for 14 days.Significant decrease in both hemoglobin content and glucose levels in the blood samples in all groups of injected rats were compared to control group.However,in all groups higher decrease was shown in the rats injected with 1 g·mL-1 ofA.indica water extracts.In addition,the present study showed no significant relationship between decreased hemoglobin content and glucose levels in blood samples,and increased doses injected.In conclusion,A.indica has the potential to decrease both hemoglobin content and blood glucose levels.

  14. Effects of L-lysine monohydrochloride on insulin and blood glucose levels in spinal cord injured rats

    Institute of Scientific and Technical Information of China (English)

    ZHANG Tian-ling; ZHAO Yu-wu; LIU Xue-yuan; DING Su-ju

    2010-01-01

    Background Hyperglycemia in brain and spinal cord could aggravate neurologic impairment. Recent studies showed that L-lysine monohydrochlonde (LMH) could increase the insulin secretion and regulate the blood glucose level. The aim of the present study was to investigate the effects of LMH on pancreatic islet B cells, the levels of endogenous insulin and blood glucose in spinal cord injured rats.Methods Forty male Wistar rats were divided into four groups, namely, normal control group, model group, high-dose LMH group (621.5 mg/kg equal to LMH 1/8 LD50), and low-dose LMH group (310.8 mg/kg equal to LMH 1/16 LD50). The model of spinal cord injured rat was established by hemi-transection at the lower right thoracic spinal cord. LMH was administered via intraperitoneal injection once spinal cord injury was produced in rats. All rats were sacrificed 48 hours after spinal cord injured. The effects of LMH on pancreatic islet B cells, the content of endogenous insulin, end the level of blood glucose were observed with immunohistochemical method, radioimmunoassay method, end biochemical analyzer, respectively. Results The insulin immunohistochemical intensities of islet B cells were significantly weaker in model group then those in normal control group (P 0.05). Conclusion LMH, but dose-dependent, might participate in the regulation of pancreatic islet B cells, and then reduce the blood glucose levels in the spinal cord injured rats.

  15. Laboratory Exercise: Study of Digestive and Regulatory Processes through the Exploration of Fasted and Postprandial Blood Glucose

    Science.gov (United States)

    Hopper, Mari K.; Maurer, Luke W.

    2013-01-01

    Digestive physiology laboratory exercises often explore the regulation of enzyme action rather than systems physiology. This laboratory exercise provides a systems approach to digestive and regulatory processes through the exploration of postprandial blood glucose levels. In the present exercise, students enrolled in an undergraduate animal…

  16. Reliability of point-of-care hematocrit, blood gas, electrolyte, lactate and glucose measurement during cardiopulmonary bypass.

    NARCIS (Netherlands)

    Steinfelder-Visscher, J.; Weerwind, P.W.; Teerenstra, S.; Brouwer, M.H.J.

    2006-01-01

    BACKGROUND: Recently, the GEM Premier blood gas analyser was upgraded to the GEM Premier 3000. In addition to pH, pCO2, pO2, Na+, K+, Ca2+, and hematocrit measurement, glucose and lactate can be measured on the GEM Premier 3000. In this prospective clinical study, the analytical performance of the G

  17. [Comparative analysis of dependence of saliva sorbitol and fructosamine levels on blood glucose level in patients with diabetes].

    Science.gov (United States)

    Morenkova, S A

    2004-01-01

    The possibility of determination of sorbitol and fructosamine in saliva has been studied in healthy volunteers and patients with diabetes. The dependence of these metabolites levels in saliva on blood glucose level was demonstrated. It is concluded that saliva sorbitol and fructosamine levels measurements may be used as diagnostic tests in diabetes and serve as indicators of efficacy of therapy in diabetes. PMID:15707277

  18. EVALUATION OF THE EFFECT OF âWAKOUBA '' ON THE LIPID PROFILE, SYSTOLIC BLOOD PRESSURE (SBP) DIASTOLIC (DBP) AND BLOOD GLUCOSE IN HYPERTENSIVE RABBITS

    OpenAIRE

    Tiekpa Wawa J; Bahi C; N’guessan J.D; Koutou A

    2014-01-01

    This study aims at evaluating the effects of Wakouba, an extract of the fronds of oil palm tree Elaeis guineensis (Jacq) traditionally used in the treatment of high blood pressure, on lipid profile, urea, creatinine, blood glucose, systolic blood pressure (SBP), diastolic (DBP) and heart rate (HR) in hypertensive rabbits. Methods: Twenty four rabbits (24) divided into six (06) groups of four rabbits each weighing between 1.5 ±3.0 to 2± 1.5 kg were used. Group 1 served as witness, group 2 sick...

  19. Blood glucose testing and primary prevention of diabetes mellitus type 2 - evaluation of the effect of evidence based patient information

    Directory of Open Access Journals (Sweden)

    Giani Guido

    2010-01-01

    Full Text Available Abstract Background Evidence-based patient information (EBPI has been recognised as important tool for informed choice in particular in the matter of preventive options. An objective, on the best scientific evidence-based consumer information about subthreshold elevated blood glucose levels (impaired fasting glucose and impaired glucose tolerance and primary prevention of diabetes, is not available yet. Thus we developed a web-based EBPI and aim to evaluate its effects on informed decision making in people 50 years or older. Methods/Design We conduct a web-based randomised-controlled trial to evaluate the effect of information about elevated blood glucose levels and diabetes primary prevention on five specific outcomes: (i knowledge of elevated blood glucose level-related issues (primary outcome; (ii attitudes to a metabolic testing; (iii intention to undergo a metabolic testing; (iv decision conflict; (v satisfaction with the information. The intervention group receives a specially developed EBPI about subthreshold elevated blood glucose levels and diabetes primary prevention, the control group information about this topic, available in the internet. The study population consists of people between 50 and 69 years of age without known diabetes. Participants will be recruited via the internet page of the cooperating health insurance company, Techniker Krankenkasse (TK, and the internet page of the German Diabetes Centre. Outcomes will be measured through online questionnaires. We expect better informed participants in the intervention group. Discussion The design of this study may be a prototype for other web-based prevention information and their evaluation. Trial registration Current Controlled Trial: ISRCTN22060616.

  20. Review of Blood Glucose Detective Methods%血糖检测方法的研究现状

    Institute of Scientific and Technical Information of China (English)

    王阳; 张松; 杨琳

    2011-01-01

    The control of the blood glucose is an important way for understanding pathogenic condition and evaluating treatment effects of mellitus diabetes. In this paper, the invasive, minimally invasive and non-invasive blood glucose detecting techniques in clinic are summarized respectively. Advantages and disadvantages of these techniques are compared and analyzed from the technical aspect. The technical principles of the current blood glucose monitoring instruments are analyzed. Non-invasive detection methods and their development foreground are specially introduced. Although there are many types of non-invasive blood glucose detectors, there is a lack of a non-invasive, continuous, dynamic, accurate, good- repeatability product, which can be widely used in home health care, and replace the traditional invasive blood glucose detector. At present, every one of the invasive, minimally invasive or non-invasive blood glucose detecting technique has its characteristic, can not be substituted each other. The non-invasive technique is the future of blood glucose detector, which still needs studied in a multi-interdisciplinary subject.%掌握血糖的变化是了解糖尿病病情和评价治疗效果的重要途径.本文从有创、微创和无创三个方面对血糖检测方法及存在问题进行了陈述;从技术方面对目前的血糖仪进行分析,着重介绍了无创检测方式的原理及发展前景.虽然无创血糖检测方法很多,但目前仍然缺乏一种无创伤、连续、动态、准确、重复性良好的方法,使之能够广泛应用于家庭保健,并取代传统的有创血糖检测仪.有创、微创、无创血糖检测方法目前各有优劣,尚无法相互取代,而无创血糖检测是未来血糖检测技术发展的方向,有待于多学科的综合研究.

  1. A tripeptide Diapin effectively lowers blood glucose levels in male type 2 diabetes mice by increasing blood levels of insulin and GLP-1.

    Directory of Open Access Journals (Sweden)

    Jifeng Zhang

    Full Text Available The prevalence of type 2 diabetes (T2D is rapidly increasing worldwide. Effective therapies, such as insulin and Glucagon-like peptide-1 (GLP-1, require injections, which are costly and result in less patient compliance. Here, we report the identification of a tripeptide with significant potential to treat T2D. The peptide, referred to as Diapin, is comprised of three natural L-amino acids, GlyGlyLeu. Glucose tolerance tests showed that oral administration of Diapin effectively lowered blood glucose after oral glucose loading in both normal C57BL/6J mice and T2D mouse models, including KKay, db/db, ob/ob mice, and high fat diet-induced obesity/T2D mice. In addition, Diapin treatment significantly reduced casual blood glucose in KKay diabetic mice in a time-dependent manner without causing hypoglycemia. Furthermore, we found that plasma GLP-1 and insulin levels in diabetic models were significantly increased with Diapin treatment compared to that in the controls. In summary, our findings establish that a peptide with minimum of three amino acids can improve glucose homeostasis and Diapin shows promise as a novel pharmaceutical agent to treat patients with T2D through its dual effects on GLP-1 and insulin secretion.

  2. Bio-enhancing effect of Piperine with Metformin on lowering blood glucose level in Alloxan induced diabetic mice

    Directory of Open Access Journals (Sweden)

    Shubham Atal

    2016-01-01

    Full Text Available Background: Diabetes mellitus is the most rampant metabolic pandemic of the 21 st century. Piperine, the chief alkaloid of Piper nigrum (black pepper is widely used in alternative and complementary therapies has been extensively studied for its bio-enhancing property. Objective: To evaluate the bio-enhancing effect of piperine with metformin in lowering blood glucose levels in alloxan-induced diabetic mice. Materials and Methods: Piperine was isolated from an extract of fruits of P. nigrum. Alloxan-induced (150 mg/kg intraperitoneal diabetic mice were divided into four groups. Group I (control 2% gum acacia 2 g/100 mL, Group II (metformin 250 mg/kg, Group III (metformin and piperine 250 mg/kg + 10 mg/kg, and Group IV (metformin and piperine 125 mg/kg + 10 mg/kg. All the drugs were administered orally once daily for 28 days. Blood glucose levels were estimated at day 0, day 14, and end of the study (day 28. Results: The combination of piperine with therapeutic dose of metformin (10 mg/kg + 250 mg/kg showed significantly more lowering of blood glucose level as compared to metformin alone on both 14 th and 28 th day (P < 0.05. Piperine in combination with sub-therapeutic dose of metformin (10 mg/kg + 125 mg/kg showed significantly more lowering of blood glucose as compared to control group and also showed greater lowering of blood glucose as compared to metformin (250 mg/kg alone. Conclusion: Piperine has the potential to be used as a bio-enhancing agent in combination with metformin which can help reduce the dose of metformin and its adverse effects.

  3. Effects of exposure to electromagnetic field radiation (EMFR generated by activated mobile phones on fasting blood glucose

    Directory of Open Access Journals (Sweden)

    Sultan Ayoub Meo

    2013-04-01

    Full Text Available Objective: Extensive use of mobile phones has been accompanied by a common public debate about possible adverse effects on human health. No study has been published so far to establish any association between the fastest growing innovation of mobile phone and fasting blood glucose. The aim was to determine the effects of exposure to electromagnetic field radiation generated by mobile phones on fasting blood glucose in Wistar Albino rats. Materials and Methods: 40 Male Albino rats (Wistar Strain were divided into 5 equally numerous groups. Group A served as the control one, group B received mobile phone radiation for less than 15 min/day, group C: 15-30 min/day, group D: 31-45 min/day, and group E: 46-60 min/day for a total period of 3 months. Fasting blood glucose was determined by using Spectrophotometer and serum insulin by Enzyme-linked Immunosorbent Assay (ELISA. The Homeostatic Model (HOMA-B was applied for the assessment of β-cell function and (HOMA-IR for resistance to insulin. Results: Wister Albino rats exposed to mobile phone radiation for longer than 15 min a day for a total period of 3 months had significantly higher fasting blood glucose (p < 0.015 and serum insulin (p < 0.01 compared to the control group. HOMA-IR for insulin resistance was significantly increased (p < 0.003 in the groups that were exposed for 15-30 and 46-60 min/day compared to the control rats. Conclusion: The results of the present study show an association between long-term exposure to activated mobile phones and increase in fasting blood glucose and serum insulin in Albino rats.

  4. [Multicenter evaluation of the reliability of five blood glucose monitoring systems].

    Science.gov (United States)

    Jday-Daly, Ismahen; Augereau-Vacher, Christine; De Curraize, Claire; Fonfrède, Michèle; Lefevre, Guillaume; Lacour, Bernard; Hennequin-Le Meur, Carole

    2011-01-01

    As part of a tender AP-HP Paris Hospitals, an assessment of the reliability record of five blood glucose monitoring systems (BGMSs) (Optium Xceed (Abbott), Contour TS (Bayer), One Touch Ultra (Lifescan), Stat Strip Xpress (Nova) and Accu Check (Roche) and an evaluation of their sensitivity to changes in hematocrit were conducted in 4 hospitals of Paris. In terms of inaccuracy, all BGMSs have submitted CV repetability under the limits of acceptability. One BGMS (Lifescan) presented a CV of reproducibility outside limit of acceptability (13.1%). The inaccuracy was measured by a comparison method on multiparameter analyser relative to the hexokinase method for two sites, the glucose oxidase for the two others. The coefficients of correlation varied from 0.8405 to 0.9303. However, according to both defined acceptability criteria (absolute value difference between the result acquired on analyzer and those determined with the BGMS), the percentage of results outside acceptability was above 20% for two BGMSs (Abbott and Lifescan). Similarly, a net effect of changes in hematocrit was observed on the results of those two BGMSs. BGMS Nova was the most reliable, because of the correction device for hematocrit and blank substractions owed to interferences. In terms of expertise, BGMSs Nova and Roche have been selected with the best analytical performance and practicability satisfactory. In the future, accreditation with standard NF/EN 22870 requested for point of care testing, will require a close collaboration between biologists and clinicians to establish a system of strict quality control to detect deviations of these BGMSs. PMID:21463996

  5. Additional benefit of higher dose green tea in lowering postprandial blood glucose

    Directory of Open Access Journals (Sweden)

    Rita Lahirin

    2015-07-01

    Full Text Available Background: Green tea contains catechins that have inhibitory effects on amylase, sucrase, and sodium-dependent glucose transporter (SGLT which result in lowering of postprandial blood glucose (PBG. This beneficial effect has been widely demonstrated using the usual dose (UD of green tea preparation. Our study was aimed to explore futher lowering of PBG using high dose (HD of green tea in healthy adolescents.Methods: 24 subjects received 100 mL infusion of either 0.67 or 3.33 grams of green tea with test meal. Fasting, PBG at 30, 60, 120 minutes were measured. Subjects were cross-overed after wash out. PBG and its incremental area under the curve (IAUC difference between groups were analyzed with paired T-test. Cathecin contents of tea were measured using high-performance liquid chromatography (HPLC.Results: The PBG of HD group was lower compared to UD (at 60 minutes =113.70 ± 13.20 vs 124.16 ± 8.17 mg/dL, p = 0.005; at 120 minutes = 88.95 ± 6.13 vs 105.25 ± 13.85 mg/dL, p < 0.001. The IAUC of HD was also found to be lower compared to UD (2055.0 vs 3411.9 min.mg/dL, p < 0.001.Conclusion: Additional benefit of lowering PBG can be achieved by using higher dose of green tea. This study recommends preparing higher dose of green tea drinks for better control of PBG.

  6. Effects of Sesame Oil on Blood Glucose and Lipid Profile in Type II Diabetic Patients Referring to The Yazd Diabetes Research Center.

    Directory of Open Access Journals (Sweden)

    F Hoseini

    2008-07-01

    Full Text Available Introduction: Type II Diabetes is one of the most prevalent endocrine diseases in the world that results from a combination of insulin resistance and ß-cell failure. Regarding importance of nutritional factors in management of diabetes, this study was designed to explore the effect of sesame oil on blood glucose and lipid profile in type II diabetic patients at Yazd Diabetes Research Center in 2007. Methods: A quasi-experimental study was conducted on 25 patients with type II diabetes mellitus (age: 51.5±6.28y; BMI:27.3±3kg/m2; disease duration:7.08±5.03y; Fasting blood glucose level: 181±51.9mg/dl. Subjects received 30 g/day sesame oil for 6 weeks. Sesame oil was supplied to the patients, who were instructed to use it in place of other cooking oils for 42 days. Plasma glucose, glycated hemoglobin (HbA1c, lipid profiles [Total cholesterol (TC, low-density lipoprotein cholesterol (LDL-C, high-density lipoprotein cholesterol (HDL-C and triglycerides (TG] were measured at baseline and after 45 days of sesame oil substitution. 24 hours dietary recalls were obtained at the start , middle and end of study. Data was analyzed using analysis of variance with repeated measures and paired t-test. Results: Following 42 days intake of sesame oil, there were significant decrease in FBS (181±51.93 vs 154±39.65 mg/dl, HbA1c (9.64 ± 2 vs 8.4 ± 1.74 percent, TC (226.68 ± 31.4 vs 199.8 ± 37.87 mg/dl, LDL-c (123.9 ± 34.56 vs 95.53 ± 32.54 mg/dl compared to pre-treatment values. (P <0.05 . Blood TG level decreased after intake of sesame oil but this difference was not significant (P=0.2.Also, the changes of HDL-c levels were not significant (P=0.1. Conclusion: Sesame oil consumption results in considerable decrease in blood sugar, HbA1c and blood lipid levels (TC and LDL-C in type II diabetics.

  7. Glucose test (image)

    Science.gov (United States)

    ... person with diabetes constantly manages their blood's sugar (glucose) levels. After a blood sample is taken and tested, it is determined whether the glucose levels are low or high. If glucose levels ...

  8. Suspension properties of whole blood and its components under glucose influence studied in patients with acute coronary syndrome

    Science.gov (United States)

    Malinova, Lidia I.; Simonenko, Georgy V.; Denisova, Tatyana P.; Dovgalevsky, Pavel Y.; Tuchin, Valery V.

    2004-05-01

    The protocol of our study includes men with acute myocardial infarction, stable angina pectoris of II and III functional classes and unstable angina pectoris. Patients with arterial hypertension, disorders in carbohydrate metabolism were excluded from the study. Blood samples taken under standardized conditions, were stabilized with citrate sodium 3,8% (1:9). Erythrocytes and platelets aggregation activity under glucose influence (in vitro) was studied by means of computer aided microphotometer -- a visual analyzer. Erythrocyte and platelets were united in special subsystem of whole blood. Temporal and functional characteristics of their aggregation were analyzed by creation of phase patterns fragments. The received data testify to interrelation of erythrocytes and platelets processes of aggregation under conditions of increasing of glucose concentration of the incubatory environment, which temporal and functional characteristics may be used for diagnostics and the prognosis of destabilization coronary blood flow at an acute coronary syndrome.

  9. Evaluation of OneTouch Verio, a new blood glucose self-monitoring system for patients with diabetes

    DEFF Research Database (Denmark)

    Littman, Karin; Petersen, Eva R.B.; Pussinen, Christel;

    2013-01-01

    Introduction. Self-monitoring of blood glucose (SMBG) is important in diabetes management. Reliable and user-friendly instruments are essential. OneTouch Verio® is a new blood glucose concentration-measuring system designed to be used by patients with diabetes and healthcare professionals. The...... objective of the present study was to evaluate the analytical performance of the OneTouch Verio®. Method. The OneTouch Verio® was evaluated by the Scandinavian evaluation of laboratory equipment for primary healthcare (SKUP) according to a protocol based on ISO 15197 and the American Diabetes Association...... (ADA) quality goals. Blood samples were collected and measured on the OneTouch Verio® by laboratory personnel and patients with diabetes (n = 91, randomized into groups receiving personal training or mail instructions for the OneTouch Verio® system). Results were compared to a validated routine method...

  10. ACUTE EFFECT OF FLUCONAZOLE, ITRACONAZOLE AND VORICONAZOLE ON BLOOD GLUCOSE IN NORMOGLYCEAMIC & DIABETIC RATS: AN EXPERIMENTAL STUDY

    Directory of Open Access Journals (Sweden)

    Jadhav Amol, Nayak BB, Vakade Kiran P, Sanghishetti Vijay Prasad, Vijay Kumar AN, Vrushali Nibrad, Raul AR

    2015-01-01

    Full Text Available Anti-fungal and antimicrobials are frequently co-prescribed either to manage or treat either the secondary complications or other diseases. Among antifungal drugs Fluconazole, Itraconazole & Voriconazole are most commonly used. The present study was undertaken to further confirm the effect of Voriconazole as well as other antifungal drugs on blood Glucose level. Aim & Objectives: 1. To Study the effect of Fluconazole, Itraconazole & Voriaconazole in Normoglycemic & Diabetic Rats on Blood Glucose. 2. To compare the effects between all drugs. Material & Methodology: Grouping: Animals divided into 8 groups in each group 6 animals. Group 1- 4: Normoglycemic rats, Group 5-8 Diabetic rats (alloxan induced Group 1,5: received vehicle (Normal saline Group 2,6: received Fluconazole (18mg/kg BW, Group 3,7 received Itraconazole (18mg/kg BW Group 4,8 received Voriconazole (18mg/kg BW. The glucose levels were estimated by Glucometer method (Accu-check active at the interval of 0, ½ hr, 1hrs, 2hrs & 4hrs after drug administration. Results: Effect on blood glucose in Normoglycemic Rats: Voriconazole had a significant hypoglycaemic effect which appeared after 1 hr (‘p’ value= 0.0102 of administration & persisted up to 2 hrs (‘p’ value=0.0001. However effect of Voriconzole was found to be declined after 2 hrs. There was no significant change in blood glucose in normoglycemic rats with Fluconazole & Itraconazole. Effect on blood glucose in Diabetic Rats: (Table 2: Voriconazole had a significant hypoglycaemic effect which appeared after 1 hr (‘p’ value=0.013 of administration & persisted up to 2 hrs (‘p’ value=0.001 in acute studies. However effect of Voriconzole was found to be declined after 2 hrs. There was no significant change in blood glucose in diabetic rats with Fluconazole & Itraconazole treated. Conclusion: Itraconazole, Fluconazole can be safely used in diabetic with fungal infections. Voriconazole should be avoided in diabetics to

  11. Related research of blood glucose, blood lipid and serum cystatin C and lower-extremity arterial disease in type 2 diabetic mellitus

    Institute of Scientific and Technical Information of China (English)

    Juan Zeng; Jie Ou; Yun-Mei He; Chun-Yu Cai

    2016-01-01

    Objective:To explore the relationship between levels of blood glucose, blood lipid and serum cystatin C and lower-extremity arterial disease in type 2 diabetic mellitus so as to provide the basis for the prevention and treatment of the disease.Methods:A total of 240 cases of patients with type 2 diabetic mellitus receiving physical examinations in our hospital from March 2014 to March 2015 were selected and divided into three groups. The control group was consisted of type 2 diabetes patients without lower-extremity arterial disease, the observation group 1 included type 2 diabetes patients with mild or moderate lower-extremity arterial disease, and the observation group 2 was formed by type 2 diabetes patients with severe lower-extremity arterial disease. Each group contained 80 cases. Then, the heights, weights, waist and hip circumferences of patients in the three groups were determined and the body mass index (BMI) and waist to hip ratio (WHR) were calculated; the fasting blood glucose (FBG), fasting insulin (FINS), insulin resistance index (HOMA-IR), 2 h postprandial blood glucose (2 h PG) and glycosylated hemoglobin (HBA1c) in two groups were detected; and the levels of serum total cholesterol(TC), triglyceride (TG), low density lipoprotein cholesterol (LDL-C), high density lipoprotein cholesterol (HDL-C), apolipoprotein A1 (apoA1), apolipoprotein B (apoB) and cystatin C (CysC) in two groups were also tested.Results:Compared with the control group, the WHR, FBG, HOMA-IR, 2 h PG, HBA1c, LDL-C, apoB and CysC all increased significantly, and the differences were statistically significant. Besides, there were statistically significances existing between the observation groups 1 and 2. What’s more, the serum levels of TC, HDL-C, TG and apoA1 in the observation groups were not significantly different from those of the control group.Conclusions: There is a close relationship between blood glucose, blood lipid, serum cystatin C level and lower-extremity arterial

  12. Aqueous extract ofOcimum tenuiflorum decreases levels of blood glucose in induced hyperglycemic tilapia (Oreochromis niloticus)

    Institute of Scientific and Technical Information of China (English)

    Amilcar Arenal; Leonardo Martn; Nestor M Castillo; Dainier de la Torre; Ubaldo Torres; Reinaldo Gonzlez

    2012-01-01

    Objective:To evaluate, in hyperglycemic tilapia [Oreochromis niloticus (O. niloticus)], the effect of this aqueous extract on blood glucose levels.Methods:The hyperglycemia inO. niloticus was induced by adding glucose to fish pond water.An aqueous extract ofOcimum tenuiflorum (O. tenuiflorum) was prepared by boiling fresh leaves and the doses of0,40,80,200 and400 mg per liter of pond water were tested.Results:The blood sugar concentration for tilapia with hyperglycemic induced was an average of50% higher than the control group.The blood glucose levels in tilapia after the induction of hyperglycemia were higher than the control group for 90 min after the treatment.The treatment with the aqueous extract ofO. tenuiflorum dropped the serum glucose level of hyperglycemic tilapia until it was similar to that of the control group and was dose dependent.Conclusions:The results indicated that O. tenuiflorum was endowed with anti-hyperglycemic activity.To our knowledge, this is the first report on the use of fish as a diabetes model to test natural extracts from plants.

  13. Effects of Zinc Supplementation on the Anthropometric Measurements, Lipid Profiles and Fasting Blood Glucose in the Healthy Obese Adults

    Directory of Open Access Journals (Sweden)

    Sepide Mahluji

    2013-02-01

    Full Text Available Purpose: The aim of this study was to assess the effects of zinc supplementation on anthropometric measures, improving lipid profile biomarkers, and fasting blood glucose level in obese people. Methods: This randomized, double- blind clinical trial was carried out on 60 obese participants in the 18-45 age range for one month. The participants were randomly divided into the intervention group, who received 30 mg/d zinc gluconate, and the placebo group who received 30mg/d starch. Anthropometric measurements (body mass index (BMI, weight and waist circumference were recorded before and at the end of study. Lipid profile biomarkers and fasting blood glucose were determined using enzymatic procedure. Analysis of Covariance (ANCOVA test was run to compare the post-treatment values of the two groups, and t-test was conducted to compare within group changes. Results: Serum zinc concentration was increased significantly in intervention group (p=0.024. BMI and body weight was significantly decreased (p=0.030 and p=0.020, respectively. Lipid profile biomarkers and fating blood glucose did not change significantly but triglyceride level was significantly decreased (p=0.006 in the intervention group. Conclusion: The obtained results indicate that zinc supplementation improves BMI, body weight, and triglyceride concentration without considerable effects on lipid profile and glucose level. Zinc can be suggested as a suitable supplementation therapy for obese people, but more studies are needed to verify the results.

  14. Effect of commercial rye whole-meal bread on postprandial blood glucose and gastric emptying in healthy subjects

    Directory of Open Access Journals (Sweden)

    Darwich Gassan

    2009-06-01

    Full Text Available Abstract Background The intake of dietary fibre has been shown to reduce the risk of developing diabetes mellitus. The aim of this study was to compare the effects of commercial rye whole-meal bread containing whole kernels and white wheat bread on the rate of gastric emptying and postprandial glucose response in healthy subjects. Methods Ten healthy subjects took part in a blinded crossover trial. Blood glucose level and gastric emptying rate (GER were determined after the ingestion of 150 g white wheat bread or 150 g whole-meal rye bread on two different occasions after fasting overnight. The GER was measured using real-time ultrasonography, and was calculated as the percentage change in antral cross-sectional area 15 and 90 minutes after completing the meal. Results No statistically significant difference was found between the GER values or the blood glucose levels following the two meals when evaluated with the Wilcoxon signed rank sum test. Conclusion The present study revealed no difference in postprandial blood glucose response or gastric emptying after the ingestion of rye whole-meal bread compared with white wheat bread. Trial registration NCT00779298

  15. High dose flaxseed oil supplementation may affect fasting blood serum glucose management in human type 2 diabetics.

    Science.gov (United States)

    Barre, Douglas E; Mizier-Barre, Kazimiera A; Griscti, Odette; Hafez, Kevin

    2008-01-01

    Type 2 diabetes is characterized partially by elevated fasting blood serum glucose and insulin concentrations and the percentage of hemoglobin as HbA1c. It was hypothesized that each of blood glucose and its co-factors insulin and HbA1c and would show a more favorable profile as the result of flaxseed oil supplementation. Patients were recruited at random from a population pool responding to a recruitment advertisement in the local newspaper and 2 area physicians. Completing the trial were 10 flaxseed oil males, 8 flaxseed oil females, 8 safflower (placebo) oil males and 6 safflower oil females. Patients visited on two pre-treatment occasions each three months apart (visits 1 and 2). At visit 2 subjects were randomly assigned in double blind fashion and in equal gender numbers to take flaxseed oil or safflower oil for three further months until visit 3. Oil consumption in both groups was approximately 10 g/d. ALA intake in the intervention group was approximately 5.5 g/d. Power was 0.80 to see a difference of 1 mmol of glucose /L using 12 subjects per group with a p impact on fasting blood serum glucose, insulin or HbA1c levels. It is concluded that high doses of flaxseed oil have no effect on glycemic control in type 2 diabetics. PMID:18391475

  16. Glucose supplementation has minimal effects on blood neutrophil functionand gene expression in vitro

    Science.gov (United States)

    During early lactation, glucose availability is low and the effect of glucose supply on bovine polymorphonuclear leukocyte (PMNL) function is poorly understood. The objective of this study was to determine the effect of glucose supplementation on the function and transcriptomic inflammatory respons...

  17. Intensive blood glucose control and vascular outcomes in patients with type 2 diabetes

    NARCIS (Netherlands)

    Patel, A.; MacMahon, S.; Chalmers, J.; Neal, B.; Billot, L.; Woodward, M.; Marre, M.; Cooper, M.; Glasziou, P.; Grobbee, D.; Hamet, P.; Harrap, S.; Heller, S.; Liu, L.; Mancia, G.; Mogensen, C.E.; Pan, C.; Poulter, N.; Rodgers, A.; Williams, B.; Bompoint, S.; Galan, B.E. de; Joshi, R.; Travert, F.

    2008-01-01

    BACKGROUND: In patients with type 2 diabetes, the effects of intensive glucose control on vascular outcomes remain uncertain. METHODS: We randomly assigned 11,140 patients with type 2 diabetes to undergo either standard glucose control or intensive glucose control, defined as the use of gliclazide (

  18. Determination of total creatine kinase activity in blood serum using an amperometric biosensor based on glucose oxidase and hexokinase.

    Science.gov (United States)

    Kucherenko, I S; Soldatkin, O O; Lagarde, F; Jaffrezic-Renault, N; Dzyadevych, S V; Soldatkin, A P

    2015-11-01

    Creatine kinase (CK: adenosine-5-triphosphate-creatine phosphotransferase) is an important enzyme of muscle cells; the presence of a large amount of the enzyme in blood serum is a biomarker of muscular injuries, such as acute myocardial infarction. This work describes a bi-enzyme (glucose oxidase and hexokinase based) biosensor for rapid and convenient determination of CK activity by measuring the rate of ATP production by this enzyme. Simultaneously the biosensor determines glucose concentration in the sample. Platinum disk electrodes were used as amperometric transducers. Glucose oxidase and hexokinase were co-immobilized via cross-linking with BSA by glutaraldehyde and served as a biorecognition element of the biosensor. The biosensor work at different concentrations of CK substrates (ADP and creatine phosphate) was investigated; optimal concentration of ADP was 1mM, and creatine phosphate - 10 mM. The reproducibility of the biosensor responses to glucose, ATP and CK during a day was tested (relative standard deviation of 15 responses to glucose was 2%, to ATP - 6%, to CK - 7-18% depending on concentration of the CK). Total time of CK analysis was 10 min. The measurements of creatine kinase in blood serum samples were carried out (at 20-fold sample dilution). Twentyfold dilution of serum samples was chosen as optimal for CK determination. The biosensor could distinguish healthy and ill people and evaluate the level of CK increase. Thus, the biosensor can be used as a test-system for CK analysis in blood serum or serve as a component of multibiosensors for determination of important blood substances. Determination of activity of other kinases by the developed biosensor is also possible for research purposes. PMID:26452867

  19. Reducing risk of closed loop control of blood glucose in artificial pancreas using fractional calculus.

    Science.gov (United States)

    Ghorbani, Mahboobeh; Bogdan, Paul

    2014-01-01

    Healthcare costs in the US are among the highest in the world. Chronic diseases such as diabetes significantly contribute to these extensive costs. Despite technological advances to improve sensing and actuation devices, we still lack a coherent theory that facilitates the design and optimization of efficient and robust medical cyber-physical systems for managing chronic diseases. In this paper, we propose a mathematical model for capturing the complex dynamics of blood glucose time series (e.g., time dependent and fractal behavior) observed in real world measurements via fractional calculus concepts. Building upon our time dependent fractal model, we propose a novel model predictive controller for an artificial pancreas that regulates insulin injection. We verify the accuracy of our controller by comparing it to conventional non-fractal models using real world measurements and show how the nonlinear optimal controller based on fractal calculus concepts is superior to non-fractal controllers in terms of average risk index and prediction accuracy. PMID:25571075

  20. A soluble activin receptor type IIB does not improve blood glucose in streptozotocin-treated mice.

    Science.gov (United States)

    Wang, Qian; Guo, Tingqing; Portas, Jennifer; McPherron, Alexandra C

    2015-01-01

    Type 1 diabetes mellitus (T1DM), or insulin dependent DM, is accompanied by decreased muscle mass. The growth factor myostatin (MSTN) is a negative regulator of muscle growth, and a loss of MSTN signaling has been shown to increase muscle mass and prevent the development of obesity, insulin resistance and lipodystrophic diabetes in mice. The effects of MSTN inhibition in a T1DM model on muscle mass and blood glucose are unknown. We asked whether MSTN inhibition would increase muscle mass and decrease hyperglycemia in mice treated with streptozotocin (STZ) to destroy pancreatic beta cells. After diabetes developed, mice were treated with a soluble MSTN/activin receptor fused to Fc (ACVR2B:Fc). ACVR2B:Fc increased body weight and muscle mass compared to vehicle treated mice. Unexpectedly, ACVR2B:Fc reproducibly exacerbated hyperglycemia within approximately one week of administration. ACVR2B:Fc treatment also elevated serum levels of the glucocorticoid corticosterone. These results suggest that although MSTN/activin inhibitors increased muscle mass, they may be counterproductive in improving health in patients with T1DM. PMID:25561902

  1. Non-invasive detection of fasting blood glucose level via electrochemical measurement of saliva.

    Science.gov (United States)

    Malik, Sarul; Khadgawat, Rajesh; Anand, Sneh; Gupta, Shalini

    2016-01-01

    Machine learning techniques such as logistic regression (LR), support vector machine (SVM) and artificial neural network (ANN) were used to detect fasting blood glucose levels (FBGL) in a mixed population of healthy and diseased individuals in an Indian population. The occurrence of elevated FBGL was estimated in a non-invasive manner from the status of an individual's salivary electrochemical parameters such as pH, redox potential, conductivity and concentration of sodium, potassium and calcium ions. The samples were obtained from 175 randomly selected volunteers comprising half healthy and half diabetic patients. The models were trained using 70 % of the total data, and tested upon the remaining set. For each algorithm, data points were cross-validated by randomly shuffling them three times prior to implementing the model. The performance of the machine learning technique was reported in terms of four statistically significant parameters-accuracy, precision, sensitivity and F1 score. SVM using RBF kernel showed the best performance for classifying high FBGLs with approximately 85 % accuracy, 84 % precision, 85 % sensitivity and 85 % F1 score. This study has been approved by the ethical committee of All India Institute of Medical Sciences, New Delhi, India with the reference number: IEC/NP-278/01-08-2014, RP-29/2014. PMID:27350930

  2. Do currently available blood glucose monitors meet regulatory standards? 1-day public meeting in Arlington, Virginia.

    Science.gov (United States)

    Klonoff, David C; Reyes, Juliet S

    2013-07-01

    Blood glucose monitors (BGMs) are approved by regulatory agencies based on their performance during strict testing conducted by their manufacturers. However, after approval, there is uncertainty whether BGMs maintain the accuracy levels that were achieved in the initial data. The availability of inaccurate BGM systems pose a public health problem because their readings serve as a basis for treatment decisions that can be incorrect. Several articles have concluded that BGMs in the marketplace may not consistently provide accurate results in accordance with the regulatory standards that led to approval. To address this growing concern, Diabetes Technology Society organized and conducted a 1-day public meeting on May 21, 2013, in Arlington, VA, presided by its president, David Klonoff, M.D., FACP, Fellow AIMBE, to determine whether BGMs on the market meet regulatory standards. The meeting consisted of four sessions in which Food and Drug Administration diabetes experts as well as leading academic clinicians and clinical chemists participated: (1) How is BGM performance determined? (2) Do approved BGMs perform according to International Organization for Standardization standards? (3) How do approved BGMs perform when used by patients and health care professionals? (4) What could be the consequence of poor BGM performance? PMID:23911191

  3. Examining the causal association of fasting glucose with blood pressure in healthy children and adolescents

    DEFF Research Database (Denmark)

    Goharian, T S; Andersen, Lars Bo; Franks, P W;

    2015-01-01

    The aim of the study was to determine whether genetically raised fasting glucose (FG) levels are associated with blood pressure (BP) in healthy children and adolescents. We used 11 common genetic variants of FG discovered in genome-wide association studies (GWAS), including the rs560887 single...... increase of 0.08 mmol l(-1) (P=2.4 × 10(-8)). FG was associated with BP, independent of other important determinants of BP in conventional multivariable analysis (systolic BP z-score: 0.32 s.d. per increase in mmol l(-1) (95% confidence interval (CI) 0.20-0.44, P=1.9 × 10(-7)), diastolic BP z-score: 0.13 s...... study could not support a causal association between FG and BP in healthy children and adolescents; however, it is possible that rs560887 has pleiotropic effects on unknown factors with a BP lowering effect or that these results were due to a lack of statistical power.Journal of Human Hypertension...

  4. Influence of the blood glucose level on the development of retinopathy of prematurity in extremely premature children

    Directory of Open Access Journals (Sweden)

    Galina V. Nicolaeva

    2015-08-01

    Full Text Available ABSTRACTPurpose:To investigate the influence of the blood glucose level on the development of retinopathy of prematurity (ROP in extremely premature infants.Methods:Sixty-four premature infants with a gestational age of less than 30 weeks and a birth weight of less than 1500 g were included in the study. Children without ROP were allocated to Group 1 (n=14, gestational age 28.6 ± 1.4 weeks, birth weight 1162 ± 322 g, and children with spontaneous regression of ROP were allocated to Group 2 (n=32, gestational age 26.5 ± 1.2 weeks, birth weight 905 ± 224 g. Children with progressive ROP who underwent laser treatment were included in Group 3 (n=18, gestational age 25.4 ± 0.7 weeks, birth weight 763 ± 138 g. The glucose level in the capillary blood of the premature infants was monitored daily during the first 3 weeks of life. A complete ophthalmological screening was performed from the age of 1 month. The nonparametric signed-rank Wilcoxon-Mann-Whitney test was used for statistical analysis.Results:The mean blood glucose level was 7.43 ± 2.6 mmol/L in Group 1, 7.8 ± 2.7 mmol/L in Group 2, and 6.7 ± 2.6 mmol/L in Group 3. There were no significant differences in the blood glucose levels between children with and without ROP, and also between children with spontaneously regressing ROP and progressive ROP (p>0.05. Additionally, there were no significant differences in the blood glucose levels measured at the first, second, and third weeks of life (p>0.05.Conclusion:The blood glucose level is not related to the development of ROP nor with its progression or regression. The glycemic level cannot be considered as a risk factor for ROP, but reflects the severity of newborns’ somatic condition and morphofunctional immaturity.

  5. The juice of fresh leaves of Catharanthus roseus Linn. reduces blood glucose in normal and alloxan diabetic rabbits

    Directory of Open Access Journals (Sweden)

    Lodagala Srinivas D

    2003-09-01

    Full Text Available Abstract Background The leaf juice or water decoction of Catharanthus roseus L. (Apocyanaceae is used as a folk medicine for the treatment of diabetes all over the world. In the present investigation, the leaf juice of C. roseus has been evaluated for its hypoglycemic activity in normal and alloxan-induced diabetic rabbits. Methods The blood glucose lowering activity of the leaf juice was studied in normal and alloxan-induced (100 mg/kg, i.v. diabetic rabbits, after oral administration at doses of 0.5, 0.75 and 1.0 ml/kg body weight. Blood samples were collected from the marginal ear vein before and also at 4, 6, 8, 10, 12, 16, 18, 20 & 24 h after drug administration and blood glucose was analyzed by Nelson-Somogyi's method using a visible spectrophotometer. The data was compared statistically by using Student's t-test. Results The leaf juice of C. roseus produced dose-dependent reduction in blood glucose of both normal and diabetic rabbits and comparable with that of the standard drug, glibenclamide. The results indicate a prolonged action in reduction of blood glucose by C. roseus and the mode of action of the active compound(s of C. roseus is probably mediated through enhance secretion of insulin from the β-cells of Langerhans or through extrapancreatic mechanism. Conclusions The present study clearly indicated a significant antidiabetic activity with the leaf juice of Catharanthus roseus and supports the traditional usage of the fresh leaves by Ayurvedic physicians for the control of diabetes.

  6. The juice of fresh leaves of Catharanthus roseus Linn. reduces blood glucose in normal and alloxan diabetic rabbits

    Science.gov (United States)

    Nammi, Srinivas; Boini, Murthy K; Lodagala, Srinivas D; Behara, Ravindra Babu S

    2003-01-01

    Background The leaf juice or water decoction of Catharanthus roseus L. (Apocyanaceae) is used as a folk medicine for the treatment of diabetes all over the world. In the present investigation, the leaf juice of C. roseus has been evaluated for its hypoglycemic activity in normal and alloxan-induced diabetic rabbits. Methods The blood glucose lowering activity of the leaf juice was studied in normal and alloxan-induced (100 mg/kg, i.v.) diabetic rabbits, after oral administration at doses of 0.5, 0.75 and 1.0 ml/kg body weight. Blood samples were collected from the marginal ear vein before and also at 4, 6, 8, 10, 12, 16, 18, 20 & 24 h after drug administration and blood glucose was analyzed by Nelson-Somogyi's method using a visible spectrophotometer. The data was compared statistically by using Student's t-test. Results The leaf juice of C. roseus produced dose-dependent reduction in blood glucose of both normal and diabetic rabbits and comparable with that of the standard drug, glibenclamide. The results indicate a prolonged action in reduction of blood glucose by C. roseus and the mode of action of the active compound(s) of C. roseus is probably mediated through enhance secretion of insulin from the β-cells of Langerhans or through extrapancreatic mechanism. Conclusions The present study clearly indicated a significant antidiabetic activity with the leaf juice of Catharanthus roseus and supports the traditional usage of the fresh leaves by Ayurvedic physicians for the control of diabetes. PMID:12950994

  7. Intravenous glucagon-like peptide 1 normalizes blood glucose after major surgery in patients with type 2 diabetes

    DEFF Research Database (Denmark)

    Meier, Juris J; Weyhe, Dirk; Michaely, Mark;

    2004-01-01

    GLP-1 (1.2 pmol x kg x min) and placebo over 8 hrs, each administered in randomized order in the fasting state. C-reactive protein concentrations of 4.9+/-4.2 mg/dL indicated a systemic inflammation. Blood was drawn in 30-min intervals for glucose (glucose oxidase), insulin, C-peptide, glucagon, and......OBJECTIVE: Hyperglycemia is a major risk factor for a poor outcome after major surgery in patients with type 2 diabetes. Intensive insulin treatment aiming at normoglycemia can markedly improve the survival of critically ill patients, but the broad clinical application is limited by its...... practicability and the risk of hypoglycemia. Therefore, the glucose-lowering effect of the incretin hormone glucagon-like peptide 1 (GLP-1) was investigated in patients with type 2 diabetes after major surgery. DESIGN: Randomised clinical study. SETTING: A surgical unit of a university hospital. PATIENTS AND...

  8. Relation between admission blood glucose levels and in-hospital and one year mortality in non-diabetic acute myocardial infarction patients

    Directory of Open Access Journals (Sweden)

    A Andishmand

    2006-01-01

    Full Text Available Introduction: Several studies have evaluated the association of admission blood glucose levels and short and long term mortality after myocardial infarction and have had different results. The aim of this study was evaluation of association between admission blood glucose levels and in-hospital and one year mortality in non-diabetic patients with AMI. Methods: In this study, demographic, clinical and Para clinical data of 120 non-diabetic patients with AMI on admission was collected and analyzed. The patients were followed for one year. Blood glucose level ≥ 140 mg/dl was defined as hyperglycemia. Results: 78% of patients were men. The mean age and admission blood glucose level was 63+13 years and 146+76mg/dl, respectively. Death due to cardio vascular causes was seen in 20% of patients in hospital and 9.8% during the one year follow up. The mean admission blood glucose level in patients who died in hospital was significantly more than live patients and also had an influence on the in-hospital outcome. Every 100mg/dl increase in blood glucose level was associated with 11% increase in in-hospital mortality risk in non-diabetic patients. Conclusion: Our results demonstrate that admission blood glucose level is a good marker for diagnosing patients with worse prognosis after AMI. We suggest that later studies should focus on optimal control of hyperglycemia with insulin in patients with AMI.

  9. RELATIONSHIP BETWEEN HEMOGLOBIN A1C AND BLOOD GLUCOSE THROUGHOUT THE DAY IN WELL-GLYCEMIC CONTROLLED MEDICAL NUTRITION THERAPY ALONE TYPE 2 DIABETIC PATIENTS

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    Objective To investigate the relationship between glycosylated hemoglobin A1 c ( HbA1 c) and blood glucose levels of eight different points throughout the day in well-glycemic-controlled medical nutrition therapy (MNT) alone type 2 diabetic patients.Methods Data were collected as capillary blood glucose value of eight different sample points among sixteen observing days in thirty MNT alone type 2 diabetic patients. The correlation between HbA1 c and capillary blood glucose value was evaluated by Pearson's correlation method.Results The r-values between HbA1 c and capillary blood glucose of 3: 00, 6: 00, and bedtime (22:00-23:00)were 0. 81,0. 79, and 0. 78, respectively(P<0.001). The best correlation was found between the mean value of 8-point blood glucose value throughout the day and HbA1 c (r=0.84, P<0.001).Conclusion Fasting blood glucose and postabsorptive blood glucose have better correlations with HbA1 c compared with other points in this group of well-glycemic-controlled MNT alone type 2 diabetic patients.

  10. Toothbrushing, Blood Glucose and HbA1c: Findings from a Random Survey in Chinese Population.

    Science.gov (United States)

    Su, Lingyu; Liu, Wenzhao; Xie, Bingwu; Dou, Lei; Sun, Jun; Wan, Wenjuan; Fu, Xiaoming; Li, Guangyue; Huang, Jiao; Xu, Ling

    2016-01-01

    Both diabetes and periodontal disease are prevalent in China. Poor oral hygiene practice is the major cause of periodontal disease. An association between oral hygiene practice and blood glucose level was reported in individuals with diabetes, but not in the general population. We examined the association in a population-based random survey recruiting 2,105 adults without previously diagnosed diabetes in Chongqing city, China. Plasma glucose and hemoglobin A1c (HbA1c) were measured, and a 2-hour oral glucose tolerance test was conducted for each respondent. Self-reported toothbrushing frequency was used as a proxy for oral hygiene practice. In a linear model controlling for potential confounders (demographic characteristics, socio-economic status, lifestyle risk factors, BMI, dental visit frequency, etc.), urban residents who barely brushed their teeth had an increase of 0.50 (95% CI: 0.10-0.90) mmol/L in fasting plasma glucose, and an increase of 0.26% (0.04-0.47%) in HbA1c, relative to those brushing ≥twice daily; for rural residents, the effects were 0.26 (0.05-0.48) mmol/L in fasting plasma glucose and 0.20% (0.09-0.31%) in HbA1c. Individuals with better oral practice tended to have lower level of blood glucose and HbA1c. Establishing good oral health behavioral habits may be conducive to diabetes prevention and control in the general population. PMID:27385509

  11. Toothbrushing, Blood Glucose and HbA1c: Findings from a Random Survey in Chinese Population

    Science.gov (United States)

    Su, Lingyu; Liu, Wenzhao; Xie, Bingwu; Dou, Lei; Sun, Jun; Wan, Wenjuan; Fu, Xiaoming; Li, Guangyue; Huang, Jiao; Xu, Ling

    2016-01-01

    Both diabetes and periodontal disease are prevalent in China. Poor oral hygiene practice is the major cause of periodontal disease. An association between oral hygiene practice and blood glucose level was reported in individuals with diabetes, but not in the general population. We examined the association in a population-based random survey recruiting 2,105 adults without previously diagnosed diabetes in Chongqing city, China. Plasma glucose and hemoglobin A1c (HbA1c) were measured, and a 2-hour oral glucose tolerance test was conducted for each respondent. Self-reported toothbrushing frequency was used as a proxy for oral hygiene practice. In a linear model controlling for potential confounders (demographic characteristics, socio-economic status, lifestyle risk factors, BMI, dental visit frequency, etc.), urban residents who barely brushed their teeth had an increase of 0.50 (95% CI: 0.10–0.90) mmol/L in fasting plasma glucose, and an increase of 0.26% (0.04–0.47%) in HbA1c, relative to those brushing ≥twice daily; for rural residents, the effects were 0.26 (0.05–0.48) mmol/L in fasting plasma glucose and 0.20% (0.09–0.31%) in HbA1c. Individuals with better oral practice tended to have lower level of blood glucose and HbA1c. Establishing good oral health behavioral habits may be conducive to diabetes prevention and control in the general population. PMID:27385509

  12. The Role of Untimed Blood Glucose in Screening for Gestational Diabetes Mellitus in a High Prevalent Diabetic Population

    Science.gov (United States)

    Cuschieri, Sarah; Craus, Johann; Savona-Ventura, Charles

    2016-01-01

    Global prevalence increase of diabetes type 2 and gestational diabetes (GDM) has led to increased awareness and screening of pregnant women for GDM. Ideally screening for GDM should be done by an oral glucose tolerance test (oGTT), which is laborious and time consuming. A randomized glucose test incorporated with anthropomorphic characteristics may be an appropriate cost-effective combined clinical and biochemical screening protocol for clinical practice as well as cutting down on oGTTs. A retrospective observational study was performed on a randomized sample of pregnant women who required an OGTT during their pregnancy. Biochemical and anthropomorphic data along with obstetric outcomes were statistically analyzed. Backward stepwise logistic regression and receiver operating characteristics curves were used to obtain a suitable predictor for GDM without an oGTT and formulate a screening protocol. Significant GDM predictive variables were fasting blood glucose (p = 0.0001) and random blood glucose (p = 0.012). Different RBG and FBG cutoff points with anthropomorphic characteristics were compared to carbohydrate metabolic status to diagnose GDM without oGTT, leading to a screening protocol. A screening protocol incorporating IADPSG diagnostic criteria, BMI, and different RBG and FBG criteria would help predict GDM among high-risk populations earlier and reduce the need for oGTT test. PMID:26998382

  13. The Role of Untimed Blood Glucose in Screening for Gestational Diabetes Mellitus in a High Prevalent Diabetic Population

    Directory of Open Access Journals (Sweden)

    Sarah Cuschieri

    2016-01-01

    Full Text Available Global prevalence increase of diabetes type 2 and gestational diabetes (GDM has led to increased awareness and screening of pregnant women for GDM. Ideally screening for GDM should be done by an oral glucose tolerance test (oGTT, which is laborious and time consuming. A randomized glucose test incorporated with anthropomorphic characteristics may be an appropriate cost-effective combined clinical and biochemical screening protocol for clinical practice as well as cutting down on oGTTs. A retrospective observational study was performed on a randomized sample of pregnant women who required an OGTT during their pregnancy. Biochemical and anthropomorphic data along with obstetric outcomes were statistically analyzed. Backward stepwise logistic regression and receiver operating characteristics curves were used to obtain a suitable predictor for GDM without an oGTT and formulate a screening protocol. Significant GDM predictive variables were fasting blood glucose (p=0.0001 and random blood glucose (p=0.012. Different RBG and FBG cutoff points with anthropomorphic characteristics were compared to carbohydrate metabolic status to diagnose GDM without oGTT, leading to a screening protocol. A screening protocol incorporating IADPSG diagnostic criteria, BMI, and different RBG and FBG criteria would help predict GDM among high-risk populations earlier and reduce the need for oGTT test.

  14. Bats: Body mass index, forearm mass index, blood glucose levels and SLC2A2 genes for diabetes.

    Science.gov (United States)

    Meng, Fanxing; Zhu, Lei; Huang, Wenjie; Irwin, David M; Zhang, Shuyi

    2016-01-01

    Bats have an unusually large volume of endocrine tissue, with a large population of beta cells, and an elevated sensitivity to glucose and insulin. This makes them excellent animal models for studying diabetes mellitus. We evaluated bats as models for diabetes in terms of lifestyle and genetic factors. For lifestyle factors, we generated data sets of 149 body mass index (BMI) and 860 forearm mass index (FMI) measurements for different species of bats. Both showed negative inter-species correlations with blood glucose levels in sixteen bats examined. The negative inter-species correlations may reflect adaptation of a small insectivorous ancestor to a larger frugivore. We identified an 11 bp deletion in the proximal promoter of SLC2A2 that we predicted would disrupt binding sites for the transcription repressor ZNF354C. In frugivorous bats this could explain the relatively high expression of this gene, resulting in a better capacity to absorb glucose and decrease blood glucose levels. PMID:27439361

  15. Bats: Body mass index, forearm mass index, blood glucose levels and SLC2A2 genes for diabetes

    Science.gov (United States)

    Meng, Fanxing; Zhu, Lei; Huang, Wenjie; Irwin, David M.; Zhang, Shuyi

    2016-01-01

    Bats have an unusually large volume of endocrine tissue, with a large population of beta cells, and an elevated sensitivity to glucose and insulin. This makes them excellent animal models for studying diabetes mellitus. We evaluated bats as models for diabetes in terms of lifestyle and genetic factors. For lifestyle factors, we generated data sets of 149 body mass index (BMI) and 860 forearm mass index (FMI) measurements for different species of bats. Both showed negative inter-species correlations with blood glucose levels in sixteen bats examined. The negative inter-species correlations may reflect adaptation of a small insectivorous ancestor to a larger frugivore. We identified an 11 bp deletion in the proximal promoter of SLC2A2 that we predicted would disrupt binding sites for the transcription repressor ZNF354C. In frugivorous bats this could explain the relatively high expression of this gene, resulting in a better capacity to absorb glucose and decrease blood glucose levels. PMID:27439361

  16. The Relationship Between Baseline Blood Pressure and Computed Tomography Findings in Acute Stroke Data From the Tinzaparin in Acute Ischaemic Stroke Trial (TAIST)

    DEFF Research Database (Denmark)

    Sare, G.M.; Bath, P.M.W.; Gray, L.J.;

    2009-01-01

    Background and Purpose-High blood pressure (BP) is present in approximate to 80% of patients with acute ischemic stroke and is independently associated with poor outcome. There are few data examining the relationship between admission BP and acute CT findings. Methods-TAIST was a randomized...... associated with baseline BP. Conclusion-Although high baseline BP is independently associated with a poor outcome after stroke, this was not shown to be through an association with increased hemorrhagic transformation, cerebral edema, or mass effect; trial design may be suboptimal to detect this. Higher SBP...

  17. Blood Glucose Levels and Performance in a Sports Camp for Adolescents with Type 1 Diabetes Mellitus: A Field Study

    OpenAIRE

    Dylan Kelly; Hamilton, Jill K.; Michael C Riddell

    2010-01-01

    Background. Acute hypo- and hyperglycemia causes cognitive and psychomotor impairment in individuals with type 1 diabetes mellitus (T1DM) that may affect sports performance. Objective. To quantify the effect of concurrent and antecedent blood glucose concentrations on sports skills and cognitive performance in youth with T1DM attending a sports camp. Design/Methods. 28 youth (ages 6–17 years) attending a sports camp carried out multiple skill-based tests (tennis, basketball, or soccer skills)...

  18. Community pharmacy-based intervention to improve self-monitoring of blood glucose in type 2 diabetic patients

    Directory of Open Access Journals (Sweden)

    Müller U

    2006-12-01

    Full Text Available Self-monitoring of blood glucose (SMBG is clearly correlated with increased life expectancy and quality of life in type 2 diabetic patients. Objective: The objective of our study was to record and assess the errors patients make in preparing, performing, and processing self-monitoring of blood glucose (SMBG. Furthermore, the study aimed to determine to what extent a single standardized SMBG instruction session in a community pharmacy might reduce the number of patients making errors or the number of errors per patient. Methods: Between May and October 2005, SMBG of 462 randomly selected patients with type 2 diabetes was monitored in 32 pharmacies specialized in diabetes care. The patients performed blood glucose self-tests using their own blood glucose meters. Self-testing was monitored using a standardized documentation sheet on which any error made during the performance of the test was recorded. If necessary, patients were instructed in the accurate operation of their meter and the use of the necessary equipment. Additionally, patients obtained written instructions. Six weeks later, assessment of the quality of patient’s SMBG was repeated.Results: During the first observation, 383 patients (83% made at least one mistake performing SMBG. By the time of the second observation, this frequency had fallen to 189 (41% (p<0.001. The average number of mistakes fell from 3.1 to 0.8 per patient. Mistakes that may potentially have led to inaccurate readings were initially recorded for 283 (61% and at study end for 110 (24% patients (p<0.001. Conclusion: It is important to periodically instruct type 2 diabetic patients in the proper SMBG technique in order to ensure accurate measurements. In this study it was shown that community pharmacies specialized in diabetes care can provide this service effectively.

  19. Hypothalamic Food Intake Regulating Areas are Involved in the Homeostasis of Blood Glucose and Plasma FFA Levels

    OpenAIRE

    Steffens, A.B.; Scheurink, A.J.W.; Luiten, P.G.M.; BOHUS, B

    1988-01-01

    The hypothalamus fulfills multiple functions, e.g., integration of food and water ingestion, various forms of social behavior and physiological neuroendocrine activities. Hypothalamic areas, particularly the ventromedial, lateral and paraventricular areas (VMH, LHA and PVN respectively), that contribute to the regulation of food intake are also involved in the regulation of blood glucose and plasma free fatty acid (FFA) levels. This regulation is controlled both directly via neural pathways a...

  20. Effects of Zinc Supplementation on the Anthropometric Measurements, Lipid Profiles and Fasting Blood Glucose in the Healthy Obese Adults

    OpenAIRE

    Sepide Mahluji; Mohammad Asghari Jafarabadi; Nazila Farrin; Yaser Khaje Bishak; Majid Mobasseri; Alireza Ostadrahimi; Laleh Payahoo

    2013-01-01

    Purpose: The aim of this study was to assess the effects of zinc supplementation on anthropometric measures, improving lipid profile biomarkers, and fasting blood glucose level in obese people. Methods: This randomized, double- blind clinical trial was carried out on 60 obese participants in the 18-45 age range for one month. The participants were randomly divided into the intervention group, who received 30 mg/d zinc gluconate, and the placebo group who received 30mg/d starch. Anthropo...

  1. The effects of hydroalcoholic extract of dracocephalum kotschyi on blood glucose and lipid profile in diabetic rats

    Directory of Open Access Journals (Sweden)

    Majid Eskandari

    2016-03-01

    Full Text Available Background & Objective: Diabetes mellitus has different side effects on various tissues of the body. This study was conducted to determine the effect of hydroalcoholic extract of Dracocephalum kotschyi on blood glucose and lipid profile of streptozotocin-induced diabetic rats. Materials & Methods: In this experimental study, 48 male Wistar rats (200-250 g randomly divided into 6 equal groups. Normal control and control diabetic received distilled water, whereas the control group received the hydroalcoholic extract of Dracocephalum kotschyi (120 mg/Kg bw. Three treatment diabetic groups received 40, 80 and 120 mg/Kg bw of hydroalcoholic extract of Dracocephalum kotschyi, respectively. All rats were treated orally by gavage which continued daily for 21 days. The level of blood glucose and lipid profile was measured at the end of the study in different groups. Results: The Mean blood glucose in the extract treatment groups decreased significantly compared to the diabetic control. The mean of total cholesterol in the treatment groups with 80 and 120 mg/Kg bw of the extract were 105.8±9.73 and 102.73±8.75 mg/dl respectively, that reduced significantly compared to the diabetic control (135.2±12.15 mg/dl. The mean of triglyceride in the treatment groups with 80 and 120 mg/Kg bw of the extract were 177.81±13.47 and 164.86±12.53 mg/dl that reduced significantly compared to the diabetic control (206.75±17.42 mg/dl. Conclusion: The extract of Dracocephalum kotschyi probably has reduced the blood glucose and lipid profile in diabetic mellitus.

  2. Timing of Peak Blood Glucose after Breakfast Meals of Different Glycemic Index in Women with Gestational Diabetes

    OpenAIRE

    Deborah Foote; Jennie C. Brand-Miller; Glynis P. Ross; Tania P. Markovic; Jimmy Chun Yu Louie

    2012-01-01

    This study aims to determine the peak timing of postprandial blood glucose level (PBGL) of two breakfasts with different glycemic index (GI) in gestational diabetes mellitus (GDM). Ten women with diet-controlled GDM who were between 30 and 32 weeks of gestation were enrolled in the study. They consumed two carbohydrate controlled, macronutrient matched bread-based breakfasts with different GI (low vs. high) on two separate occasions in a random order after an overnight fast. PBGLs were assess...

  3. A Comparative Study of Blood Glucose Measurements Using Glucometer Readings and the Standard Method in the Diagnosis of Neonatal Hypoglycemia

    OpenAIRE

    Mohammad Torkaman; Gholamreza Bagheri; Ahmad Ahmadi; Amin Saburi

    2016-01-01

    Background: Hypoglycemia is one of the most common neonatal disorders, associated with severe complications. There has been a great deal of controversy regarding the definition and screening of hypoglycemia. Therefore, in this study, we aimed to determine a cut-off value for blood glucose level in glucometer readings. Methods: This cross-sectional study was conducted on 238 newborns at risk of hypoglycemia, admitted to Baqiyatallah Hospital of Tehran, Iran in 2012; the subjects were selected ...

  4. Optimal blood glucose control in severely burned patients: a long way to go, but one step closer

    OpenAIRE

    Kamolz, Lars-Peter; Pieber, Thomas; Smolle-Jüttner, Freyja M; Lumenta, David B

    2013-01-01

    Over the past years there has been a significant decrease in mortality and morbidity in patients suffering from severe burns due to improved burn wound management and approaches in critical care. Survival is no longer the exception, but unfortunately death still occurs. One of the key elements concerning state-of-the-art burn care is blood glucose control and insulin therapy; it is well known that burn-induced hyperglycaemia is associated with adverse clinical outcomes. However, controversy f...

  5. Effect of low glycemic index food and postprandial exercise on blood glucose level, oxidative stress and antioxidant capacity

    OpenAIRE

    糟谷, 憲明; 太田, 昌一郎; 髙波, 嘉一; Kawai, Yukari; 井上, 裕; 村田, 勇; 金本, 郁男

    2015-01-01

    Low glycemic index (GI) food and postprandial exercise are non?drug therapies for improving postprandial hyperglycemia. The present randomized, crossover study investigated the effect of low GI food combined with postprandial exercise on postprandial blood glucose level, oxidative stress and antioxidant capacity. A total of 13 healthy subjects were each used in four experiments: i) rice only (control), ii) salad prior to rice (LGI), iii) exercise following rice (EX) and iv) salad prior to ric...

  6. Effect of low glycemic index food and postprandial exercise on blood glucose level, oxidative stress and antioxidant capacity

    OpenAIRE

    KASUYA, NORIAKI; Ohta, Shoichiro; TAKANAMI, YOSHIKAZU; Kawai, Yukari; Inoue, Yutaka; MURATA, ISAMU; Kanamoto, Ikuo

    2015-01-01

    Low glycemic index (GI) food and postprandial exercise are non-drug therapies for improving postprandial hyperglycemia. The present randomized, crossover study investigated the effect of low GI food combined with postprandial exercise on postprandial blood glucose level, oxidative stress and antioxidant capacity. A total of 13 healthy subjects were each used in four experiments: i) rice only (control), ii) salad prior to rice (LGI), iii) exercise following rice (EX) and iv) salad prior to ric...

  7. Determination of total creatine kinase activity in blood serum using an amperometric biosensor based on glucose oxidase and hexokinase

    OpenAIRE

    Kucherenko, Ivan S; Soldatkin, Oleksandr O; Lagarde, Florence; Jaffrezic-Renault, Nicole; Dzyadevych, S.V.; Soldatkin, A.P.

    2015-01-01

    International audience Creatine kinase (CK: adenosine-5-triphosphate-creatine phosphotransferase) is an important enzyme of muscle cells; the presence of a large amount of the enzyme in blood serum is a biomarker of muscular injuries, such as acute myocardial infarction. This work describes a bi-enzyme (glucose oxidase and hexokinase based) biosensor for rapid and convenient determination of CK activity by measuring the rate of ATP production by this enzyme. Simultaneously the biosensor de...

  8. THE EPPECT OF 8- WEEK AEROBIC EXERCISE ON BLOOD GLUCOSE AND BODY MASS IN FEMALE DIABETES II PATIENTS

    OpenAIRE

    Seyed Mohammad Marandi; Fahimeh Esfarjani; Fatemeh Rashidi

    2011-01-01

    This study aims at finding the effect of 8-week aerobic exercise on blood glucose and bodymass in female diabetes II patients. Thirty Five women with type II diabetes were purposefullyselected and divided to a control group (n=17) and an exercise group (n=18). The trainingprogram which continued three times a week for eight weeks included 60-minute aerobicexercises with the intensity of 65 to 70 percent of maximal heart rate. The results of the dataanalysis indicated that there is significant...

  9. MAINTAINING PHYSIOLOGICAL STATE FOR EXCEPTIONAL SURVIVAL: WHAT IS THE NORMAL LEVEL OF BLOOD GLUCOSE AND DOES IT CHANGE WITH AGE?

    OpenAIRE

    Yashin, Anatoli I.; Ukraintseva, Svetlana V.; Arbeev, Konstantin G.; Akushevich, Igor; Arbeeva, Liubov S.; Kulminski, Alexander M.

    2009-01-01

    The levels of blood glucose (BG) in humans tend to increase with age deviating from the norm specified for the young adults. Such elevation is often considered as a factor contributing to an increase in risks of disease and death. The proper use of intervention strategies coping with or preventing consequences of BG elevation requires understanding the roles of external forces and intrinsic senescence in this process. To address these issues, we performed analyses of longitudinal data on BG c...

  10. Liver kinetics of glucose analogs measured in pigs by PET: importance of dual-input blood sampling

    DEFF Research Database (Denmark)

    Munk, O L; Bass, L; Roelsgaard, K; Bender, D; Hansen, S B; Keiding, S

    2001-01-01

    parameters, because of ignorance of the dual blood supply from the hepatic artery and the portal vein to the liver. METHODS: Six pigs underwent PET after [15O]carbon monoxide inhalation, 3-O-[11C]methylglucose (MG) injection, and [18F]FDG injection. For the glucose scans, PET data were acquired for 90 min......Metabolic processes studied by PET are quantified traditionally using compartmental models, which relate the time course of the tracer concentration in tissue to that in arterial blood. For liver studies, the use of arterial input may, however, cause systematic errors to the estimated kinetic....... Hepatic arterial and portal venous blood samples and flows were measured during the scan. The dual-input function was calculated as the flow-weighted input. RESULTS: For both MG and FDG, the compartmental analysis using arterial input led to systematic underestimation of the rate constants for rapid blood...

  11. Pharmaceutical care in diabetes: quantifying and evaluating community pharmacy’s support to patients performing blood glucose self-monitoring

    OpenAIRE

    Storimans, M.J.

    2006-01-01

    The high prevalence and incidence of diabetes mellitus and its complications have led to a serious growth in the demand for diabetes-related health care in the Netherlands. Since self-management by the patient is a cornerstone of the treatment plan, self-management education has become an important part of diabetes care. One aspect of self-management education is self-monitoring of blood glucose (SMBG). SMBG is a technique that enables patients to monitor and react to changes in their blood g...

  12. Effect of basal insulin combined with acarbose on blood glucose level and complications in patients with newly diagnosed elderly diabetes

    Institute of Scientific and Technical Information of China (English)

    Yu-Qing Guo; Chen-Ru Zhang; Ai-Ge Yang; Fan Liu; Shan-Shan Dong; Yan Kang

    2016-01-01

    Objective:To analyze the effect of basal insulin combined with acarbose on blood glucose level and complications in patients with newly diagnosed elderly diabetes.Methods:A total of 135 cases of patients with newly diagnosed elderly diabetes who were treated in our hospital from July 2012 to January 2015 were enrolled as research subjects and divided into observation group 66 cases and control group 69 cases according to different treatment methods. Control group received acarbose therapy alone, observation group received basal insulin combined with acarbose therapy, and then differences in blood glucose level, oxidative stress indicators, nerve conduction velocity, vascular injury and inflammatory factor levels of two groups were compared.Results:FPG, 2hPG and HbA1C levels of observation group after treatment were lower than those of control group; AGE-P, MDA and NADPH levels were lower than those of control group, and SOD level was higher than that of control group; median MNCV, ulnar MNCV, tibial MNCV, median SNCV and sural SNCV levels were higher than those of control group; sVCAM-1, hs-CRP and IL-6 levels were lower than those of control group. Conclusion:Basal insulin combined with acarbose therapy for patients with newly diagnosed elderly diabetes can effectively optimize the levels of blood glucose and complication-related factors, and it has active clinical significance.

  13. Influence of blood glucose level, age and fasting period on non-pathological FDG uptake in heart and gut

    Energy Technology Data Exchange (ETDEWEB)

    Groot, Michel de; Meeuwis, Antoi P.W.; Kok, Peter J.M.; Corstens, Frans H.M.; Oyen, Wim J.G. [University Medical Center Nijmegen, Department of Nuclear Medicine (565), Nijmegen (Netherlands)

    2005-01-01

    Increased, non-pathological FDG uptake in myocardium, stomach and bowel is frequently observed while performing clinical positron emission tomography (PET) studies. This ''physiological'' increased FDG uptake is not related to (oncological) disease and is unwanted since it may interfere with correct image reading. We evaluated the role of several patient-related factors that may have an influence on this phenomenon. One hundred and seventy-five non-diabetic patients with malignant diseases, referred to our department for routine whole-body FDG-PET, were retrospectively evaluated. Age, blood glucose levels and duration of the fasting period were recorded. FDG uptake in myocardium, bowel and stomach was visually graded. Statistical analysis showed that increased FDG uptake in myocardium, bowel and stomach was not significantly correlated to blood glucose level, age or duration of fasting. Most patients who underwent repeated PET scans (92 scans in 25 patients), showed no or minor changes in uptake in bowel and stomach on the consecutive scans, while myocardial uptake was more variable. Age, fasting period and blood glucose levels did not influence physiological uptake. However, there seemed to be a patient-specific pattern for stomach and bowel uptake. (orig.)

  14. The Comparative Evaluation of the Effect of the Foods with Different Glycemic Indices on Blood Glucose and Serum Free Fatty Acids in Cycling, Male Athletes

    Directory of Open Access Journals (Sweden)

    Asadi, J. (PhD

    2014-05-01

    Full Text Available Background and Objective: Carbohydrates are considered as the major source of energy in physical activity. Studies show that consumption of carbohydrate foods before exercise can balance blood glucose and free fatty acids and increase athletes’ performance. In this study , we compared the effect of three kinds of foods with different glycemic indices on blood glucose (BG and serum free fatty acids (FFA in cycling ,male athletes. Material and Methods: In this clinical trial, 21 members of national cycling team randomly allocated to three equal groups of glucose (low glycemic index ، lentil (low glycemic index and potato (high glycemic index. First, Fasting blood samples (5ml were obtained to measure BG and FFA . Then the subjects were asked to eat their foods. After 45 mins of rest, they pedaled with maximal oxygen consumption VO2max for two hours and again their blood samples were taken to compare with the levels of before interventions. Results: Glucose consumption resulted in a significant decrease in FFA level after 2 hours of pedaling (P = 0.01 but no significant change in BG level. Plasma glucose was higher after eating lentil than that of potato (P<0.05, but it was not true for FFA level of both groups. Conclusion: Based on the results, the pre-exercise use of low glycemic index (lentil compared to high glycemic index (potato can better lead to increased blood glucose during exercise. Keywords: Glycemic Index; Blood Glucose; Serum Free Fatty Acids; Cyclists

  15. Basal insulin therapy strategy is superior to premixed insulin therapy in the perioperative period blood glucose management

    Institute of Scientific and Technical Information of China (English)

    HUANG Qing-xian; LOU Fu-chen; WANG Ping; LIU Qian; WANG Kun; ZHANG Li; ZHU Lei

    2013-01-01

    Background The probability and risk of operations increase in patients with type 2 diabetes mellitus.For diabetic patients,blood glucose control is a key factor to improving the prognosis of surgery.During perioperative period,insulin therapy is usually advised to be used for surgical patients with type 2 diabetes.However,the insulin regimen which one is better remains controversial.In this study,we estimated the efficacy,safety and advantage of different insulin therapy strategy during perioperative period.Methods A total of 1086 cases of surgical patients with type 2 diabetes mellitus enrolled in the present study.According to the glucose level at admission,all patients were divided into relatively high glucose group (group A,fasting blood glucose (FBG) <13.9 mmol/L) and higher glucose group (group B,FBG >13.9 mmol/L).Patients in group A randomly accepted premixed insulin twice a day,or basal insulin plus oral medications,and were divided into group A1 and A2 respectively.Patients in group B randomly received premixed insulin twice daily,basal insulin plus oral hypoglycemic agents,or basal insulin plus preprandial insulin,and were divided into group B1,B2 and B3 respectively.The data of the preoperative preparation time,the daily doses of insulin used in different periods,postoperative incision healed installments,hypoglycemic events,the total hospitalization time,postoperative complications were all collected and statistically analyzed.Results Compared the main outcome measures in groups treated by premixed insulin therapy,both in preoperative preparation and postoperative period,the daily insulin dosage and the frequency of hypoglycemic events were decreased in groups treated by basal insulin therapy (P <0.05).The preoperative preparation time and the total hospitalization time in groups with basal insulin therapy were shorter than that in groups with premixed insulin therapy (P <0.05).The incision healing rate of stage Ⅰ,Ⅱ and Ⅲ among different

  16. The long term oral regulation of blood glucose in diabetic patients by using of Escherichia coli Nissle 1917 expressing CTB-IGF-1 hybrid protein.

    Science.gov (United States)

    Bazi, Zahra; Jalili, Mahsa; Hekmatdoost, Azita

    2013-11-01

    Regarding to the high prevalence and comorbidities of chronic high blood glucose in diabetic patients and the limited efficacy and current painful treatments. It is necessary to improve new treatments that are non-invasive and long-term for controlling blood glucose. Recent studies have shown that the healthy microflora in different body organs can perform as the gene vectors for expressing different types of gene therapies in situ. We have proposed that by constructing a recombinant Escherichia coli Nissle 1917 that expresses CTB-IGF-1 hybrid gene under control of ompC glucose sensitive promoter, the intestinal glucose level can be regulated. This method in comparison with other methods is a non-invasive way to control the blood glucose orally and it can be used for all types of diabetes. PMID:24074833

  17. Dioscorea dumetorum-Fed Rats Exhibited Decreased Body Weight, Blood Glucose, and Insulin in STZ-induced Diabetes

    Directory of Open Access Journals (Sweden)

    Henrietta Aritetsoma Ogbunugafor

    2014-02-01

    Full Text Available Background: Preventive measures that could slow down the rising incidences of diabetes mellitus are essential. The use of neglected local foods, which have effects on this chronic disease beyond basic nutrition as dietary controls, is desirable. Objective: The effect of Dioscorea dumetorum (Kunth Pax (Dioscoreaceae feed on satiety, weight, blood glucose, and insulin levels were investigated in streptozotocin-induced diabetic rats. Methods: Twenty adult male rats in four groups of five were used for the experiment. Three groups – D. dumetorum, glibenclamide, and standard pellet-fed rats were induced with diabetes by i.p. administration of 50mg kg-1 streptozotocin, while the fouth group (? served as a nondiabetic control. D. dumetorum was fed at 15g daily for ten days before induction, and after induction, feeding continued. Glibenclamide was orally administered 5mg kg-1 daily. Both the untreated and non-diabetic rats were kept on standard rat pellets. Feed intake, weight, and blood glucose concentration were monitored daily, while insulin level was measured on day two and day six after inductions. Results: Average feed intake for non-diabetic rats was 15g for D. dumetorum per day, which dropped to 10.3g after induction of diabetes. Weight of normal non-diabetic rats consistently increased (142.61 ± 4.37g – 169.43 ± 8.61g for the duration (17 days of the experiment. The D. dumetorum-fed rats showed weight reduction of 5.4%, glibenclamide 4.0%, and untreated diabetic 6.15%. Non-diabetic rats blood glucose levels ranged between 70 to 100mg dL-1 .Functional Foods in Health and Disease 2014; 4(2:87- 97 Page 88 of 97 Streptozotocin (STZ (i.p. administration increased blood glucose levels from 370% to 626% in the rats. D. dumetorum-fed rats showed reduced (p<0.05 blood glucose levels of 22.6%. Glibenclamide had 5.5% reduction (p<0.05. Insulin was absent in D. dumetorum-fed rats, whereas 0.95ng ml-1 of insulin was detected in glibenclamide

  18. Does self monitoring of blood glucose as opposed to urinalysis provide additional benefit in patients newly diagnosed with type 2 diabetes receiving structured education? The DESMOND SMBG randomised controlled trial protocol

    Directory of Open Access Journals (Sweden)

    Dallosso Helen M

    2012-03-01

    Full Text Available Abstract Background The benefit of self-monitoring of blood glucose (SMBG in people with type 2 diabetes on diet or oral agents other than sulphonylureas remains uncertain. Trials of interventions incorporating education about self-monitoring of blood glucose have reported mixed results. A recent systematic review concluded that SMBG was not cost-effective. However, what was unclear was whether a cheaper method of self-monitoring (such as urine glucose monitoring could produce comparable benefit and patient acceptability for less cost. Methods/Design The DESMOND SMBG trial is comparing two monitoring strategies (blood glucose monitoring and urine testing over 18 months when incorporated into a comprehensive self-management structured education programme. It is a multi-site cluster randomised controlled trial, conducted across 8 sites (7 primary care trusts in England, UK involving individuals with newly diagnosed Type 2 diabetes. The trial has 80% power to demonstrate equivalence in mean HbA1c (the primary end-point at 18 months of within ± 0.5% assuming 20% drop out and 20% non-consent. Secondary end-points include blood pressure, lipids, body weight and psychosocial measures as well as a qualitative sub-study. Practices were randomised to one of two arms: participants attend a DESMOND programme incorporating a module on self-monitoring of either urine or blood glucose. The programme is delivered by accredited educators who received specific training about equipoise. Biomedical data are collected and psychosocial scales completed at baseline, and 6, 12, and 18 months post programme. Qualitative research with participants and educators will explore views and experiences of the trial and preferences for methods of monitoring. Discussion The DESMOND SMBG trial is designed to provide evidence to inform the debate about the value of self-monitoring of blood glucose in people with newly diagnosed type 2 diabetes. Strengths include a setting in

  19. An experimental research of the individual correlation between saliva glucose and blood glucose%唾液葡萄糖与血糖个体相关性的研究

    Institute of Scientific and Technical Information of China (English)

    刘琳琳; 李玲; 李蒙; 项贵明; 蒲晓允

    2011-01-01

    目的 探讨不同个体唾液葡萄糖和血糖值的相关性及重复性,为制定血糖个性化监测化方案奠定基础.方法 选取临床确诊糖尿病患者为研究对象,用自制2,4,6-三溴-3-羟基苯甲酸为显色底物,在Hitachi-7150上测定不同个体餐前唾液葡萄糖与血糖浓度,计算不同个体两者的关系数.结果 不同糖尿病患者唾液葡萄糖与血糖相关系数有较大差别,餐前相关系数平均为0.85,餐后相关系数平均为0.79,餐前相关系数3个月内的变异系数CV<5%.结论 糖尿病患者餐前唾液葡萄糖浓度与血糖浓度相关系数较高,而且比较稳定,可用餐前唾液葡萄糖浓度替代血糖浓度,开展无创快速检测.%Objective To explore the individual correlation between saliva glucose and blood glucose and its reproducibility to establish foundation for formulate individual monitoring scheme of blood glucose. Methods Patients with definitely diagnosis of diabetes mellitus were enrolled and the levels of fasting saliva glucose and fasting blood glucose were detected on Hitachi7150, using self-made 2,4,6-tribromo-3-hydroxybenzoic acid(TBHBA) as chromogenic substrate. The correlation coefficient between saliva and blood glucose were calculated for every subjects. Results The individual correlation coefficients between saliva glucose and blood glucose varies greatly between different patients. The average fasting correlation coefficient was 0. 85,the average postprandial correlation coefficient was 0. 79 and the coefficient of variability of fasting correlation coefficient was less than 5% within three months. Conclusion The individual fasting correlation coefficient between saliva glucose and blood glucose could be relatively high and stable. Fasting blood glucose could be replaced by fasting saliva glucose for the noninvasive and fast detection.

  20. Consensus report: the current role of self-monitoring of blood glucose in non-insulin-treated type 2 diabetes.

    Science.gov (United States)

    Klonoff, David C; Blonde, Lawrence; Cembrowski, George; Chacra, Antonio Roberto; Charpentier, Guillaume; Colagiuri, Stephen; Dailey, George; Gabbay, Robert A; Heinemann, Lutz; Kerr, David; Nicolucci, Antonio; Polonsky, William; Schnell, Oliver; Vigersky, Robert; Yale, Jean-François

    2011-11-01

    The Coalition for Clinical Research--Self-Monitoring of Blood Glucose Scientific Board convened a meeting in San Francisco, CA, July 20-21, 2011, to discuss the current practice of self-monitoring of blood glucose (SMBG) in non-insulin-treated (NIT) type 2 diabetes mellitus (T2DM). Twelve physician panel members from academia, practice, and government attended this meeting. These experts came from the United States, Brazil, Canada, France, Germany, Italy, and the United Kingdom. In addition, three consultants from Australia, Germany, and the United States contributed to the group's final report. This coalition was organized by Diabetes Technology Society. Self-monitoring of blood glucose was studied from eight perspectives related to patients with NIT T2DM: (1) epidemiological studies; (2) randomized controlled trials (RCT)s and meta-analyses; (3) targets, timing, and frequency of SMBG use; (4) incidence and role of SMBG in preventing hypoglycemia with single-drug regimens and combination regimens consisting of antihyperglycemic agents other than secretagogues and insulin; (5) comparison of SMBG with continuous glucose monitoring; (6) technological capabilities and limitations of SMBG; (7) barriers to appropriate use of SMBG; and (8) methods and end points for appropriate future clinical trials. The panel emphasized recent studies, which reflect the current approach for applying this intervention. Among the participants there was consensus that: SMBG is an established practice for patients with NIT T2DM, and to be most effective, it should be performed in a structured format where information obtained from this measurement is used to guide treatment; New, high-quality efficacy data from RCTs have demonstrated efficacy of SMBG in NIT T2DM in trials reported since 2008; Both patients and health care professionals require education on how to respond to the data for SMBG to be effective; and Additional well-defined studies are needed to assess the benefits and costs of

  1. Perspectives of patients with type 1 or insulintreated type 2 diabetes on self-monitoring of blood glucose : a qualitative study

    NARCIS (Netherlands)

    Hortensius, Johanna; Kars, Marijke C.; Wierenga, Willem S.; Kleefstra, Nanne; Bilo, Henk J. G.; van der Bijl, Jaap J.

    2012-01-01

    Background: Self-monitoring of blood glucose (SMBG), including self-regulation, is an important tool to achieve good glycemic control. However, many patients measure their glucose concentrations less often than is recommended. This study investigates patients' perspectives of SMBG and all relevant a

  2. Thyroid hormone stimulated glucose uptake in human mononuclear blood cells from normal persons and from patients with non-insulin-dependent diabetes mellitus

    DEFF Research Database (Denmark)

    Kvetny, J; Matzen, L

    1989-01-01

    Thyroxine and T3 induced oxygen consumption and glucose uptake were studied in vitro in mononuclear blood cells isolated from patients with non-insulin-dependent diabetes mellitus (NIDDM) and from non-diabetic control persons. Cellular oxygen consumption and glucose uptake were promptly increased...

  3. Relationship between blood glucose and carotid intima media thickness: A meta-analysis

    Directory of Open Access Journals (Sweden)

    Einarson Thomas R

    2010-08-01

    Full Text Available Abstract Background Increased coronary intima media thickness (CIMT has been associated with adverse cardiovascular outcomes, as have increased glucose levels. The link has not been established between glucose and CIMT; therefore, we sought to assess the relationship between glucose and CIMT. Methods Medline, EMBASE, Scopus, and Cochrane databases were searched from inception through 2009 for original research reporting both postprandial glucose levels and CIMT measurements. Glucose was classified as normal, impaired, or diabetic. Outputs included inverse variance weighted effect size and also average correlation (using the Wang and Bushman approach. Data were combined using a random effects meta-analytic model. Heterogeneity as assessed using χ2 and I2; bias was examined using Egger plots and Begg-Mazumdar tau. Polynomial functions (i.e., linear, quadratic, cubic, quartic were fit to the data and the Akaike Information Criteria were used to select the optimal model. Results We identified 172 papers; 161 were rejected (19 inappropriate design, 8 had selected patients, 101 inappropriate outcomes leaving 11 accepted. We used data from 15,592 patients (8250 normals, 3013 impaired glucose, 4329 diabetics. There was no evidence of heterogeneity or publication bias. The overall correlation was 0.082 (CI95%:0.066-0.098; the overall effect size was 0.294 (0.245-0.343 between diabetics and normals and 0.137 (0.072-0.202 between normals and those with impaired glucose. The equation of best fit was linear (CIMT = 0.828 + 0.009*glucose. Conclusions There is a small but significant relationship between postprandial glucose levels and CIMT, which have both been associated with adverse cardiovascular outcomes.

  4. Comprehensive investigation of postmortem glucose levels in blood and body fluids with regard to the cause of death in forensic autopsy cases.

    Science.gov (United States)

    Chen, Jian-Hua; Michiue, Tomomi; Inamori-Kawamoto, Osamu; Ikeda, Sayuko; Ishikawa, Takaki; Maeda, Hitoshi

    2015-11-01

    The serum glucose level is regulated within a narrow range by multiple factors under physiological conditions, but is greatly modified in the death process and after death. The present study comprehensively investigated glucose levels in blood and body fluids, including pericardial fluid (PCF), cerebrospinal fluid (CSF) and vitreous humor, reviewing forensic autopsy cases (n=672). Right heart blood glucose level was often higher than at other sites, and the CSF glucose level was the lowest, showing greater dissociation in acute/subacute death cases. The glucose level was higher in the diabetic (high HbA1c) than in the non-diabetic (low HbA1c) group at each site (pdeath due to ischemic heart disease. Fatal methamphetamine (MA) abuse, sepsis, malnutrition (starvation) and hypoglycemia due to antidiabetics showed markedly lower blood glucose levels. Ketones in bilateral cardiac blood and PCF were increased in diabetic ketoacidosis and fatal alcohol abuse as well as in most cases of hyperthermia (heatstroke), hypothermia (cold exposure) and malnutrition. These findings suggest that combined analysis of glucose, HbA1c and ketones in blood and body fluids is useful to investigate not only fatal diabetic metabolic disorders but also death processes due to other causes, including alcohol and MA abuse, as well as thermal disorders, sepsis and malnutrition. PMID:26593993

  5. An artificial pancreas for automated blood glucose control in patients with Type 1 diabetes

    DEFF Research Database (Denmark)

    Schmidt, Signe; Boiroux, Dimitri; Ranjan, Ajenthen;

    2015-01-01

    Automated glucose control in patients with Type 1 diabetes is much-coveted by patients, relatives and healthcare professionals. It is the expectation that a system for automated control, also know as an artificial pancreas, will improve glucose control, reduce the risk of diabetes complications...... and markedly improve patient quality of life. An artificial pancreas consists of portable devices for glucose sensing and insulin delivery which are controlled by an algorithm residing on a computer. The technology is still under development and currently no artificial pancreas is commercially available....... This review gives an introduction to recent progress, challenges and future prospects within the field of artificial pancreas research....

  6. Effects of a checklist on self-assessment of blood glucose level by a memory-impaired woman with diabetes mellitus.

    OpenAIRE

    Wong, S E; Seroka, P L; Ogisi, J

    2000-01-01

    This study evaluated effects of a checklist on the accuracy of self-assessment of blood glucose level by a diabetic woman with memory impairments caused by viral encephalitis. The checklist consisted of 54 steps for operating an electronic glucometer, which the subject performed in sequence and checked off when completed. Following introduction of the checklist, the percentage of steps completed correctly increased in simulated and actual blood glucose tests and yielded clinically useful info...

  7. Blood glucose and meal patterns in time-blinded males, after aspartame, carbohydrate, and fat consumption, in relation to sweetness perception.

    Science.gov (United States)

    Melanson, K J; Westerterp-Plantenga, M S; Campfield, L A; Saris, W H

    1999-12-01

    In a study of the impact of aspartame, fat, and carbohydrate on appetite, we monitored blood glucose continuously for 431 (SE 16) min. Ten healthy males (19-31 years) participated in three time-blinded visits. As blood glucose was monitored, appetite ratings were scored at randomized times. On the first meal initiation, volunteers consumed one of three isovolumetric drinks (aspartame, 1 MJ simple carbohydrate, and 1 MJ high-fat; randomized order). High-fat and high-carbohydrate foods were available ad libitum subsequently. Blood glucose patterns following the carbohydrate drink (+1.78 (SE 0.28) mmol/l in 38 (SE 3) min) and high-fat drink (+0.83 (SE 0.28) mmol/l in 49 (SE 6) min) were predictive of the next intermeal interval (R 0.64 and R 0.97 respectively). Aspartame ingestion was followed by blood glucose declines (40% of subjects), increases (20%), or stability (40%). These patterns were related to the volunteers' perception of sweetness of the drink (R 0.81, P = 0.014), and were predictive of subsequent intakes (R -0.71, P = 0.048). For all drinks combined, declines in blood glucose and meal initiation were significantly associated (chi 2 16.8, P blood glucose responses and intermeal intervals correlated significantly (R 0.715, P = 0.0001), and sweetness perception correlated negatively with hunger suppression (R -0.471, P = 0.015). Effects of fat, carbohydrate, and aspartame on meal initiation, meal size, and intermeal interval relate to blood glucose patterns. Varied blood glucose responses after aspartame support the controversy over its effects, and may relate to sweetness perception. PMID:10690159

  8. Relation between admission blood glucose levels and in-hospital and one year mortality in non-diabetic acute myocardial infarction patients

    OpenAIRE

    A Andishmand; MH Soltani; Emami, M; Shariat, N; L. Bahadorzadeh; M Rafiei; M Sadr-Bafghi; M Motafaker; Namayandeh, M.

    2006-01-01

    Introduction: Several studies have evaluated the association of admission blood glucose levels and short and long term mortality after myocardial infarction and have had different results. The aim of this study was evaluation of association between admission blood glucose levels and in-hospital and one year mortality in non-diabetic patients with AMI. Methods: In this study, demographic, clinical and Para clinical data of 120 non-diabetic patients with AMI on admission was collected and analy...

  9. Quantitative classification of HbA1C and blood glucose level for diabetes diagnosis using neural networks

    International Nuclear Information System (INIS)

    In this study, artificial neural network structures were used for the quantitative classification of Haemoglobin A1C and blood glucose level for diabetes diagnosis as a non-invasive measurement technique. The neural network structures make inferences from the relationship between the palm perspiration and blood data values. For this purpose, feed forward multilayer, Elman, and radial basis neural network structures were used. The quartz crystal microbalance type and humidity sensors were used for the detection of palm perspiration rates. Total 297 volunteer's data is used in this study. Three quarters of the data was used to train the neural networks. The remaining data were used as test data. The best results for the quantitative classification were obtained from the feed forward NN structure for the detection of the glucose and HbA1C level quantities. And, the performances of all neural networks for the HbA1C value were better than the performances of these neural networks for the glucose level.

  10. Sodium-glucose cotransporter-2 inhibitors and blood pressure decrease: a valuable effect of a novel antidiabetic class?

    Science.gov (United States)

    Imprialos, Konstantinos P; Sarafidis, Pantelis A; Karagiannis, Asterios I

    2015-11-01

    Diabetes mellitus is a major issue of public health, affecting more than 300 million people worldwide. Inhibitors of the sodium-glucose cotransporter-2 (SGLT-2) in the renal proximal tubule are a novel class of agents for the treatment of type 2 diabetes mellitus. Inhibition of the SGLT-2 results in reduced glucose reabsorption and improvement in glycemic control. Alongside glucose excretion, SGLT-2 inhibitors also have mild natriuretic and diuretic effects, combining actions of a proximal tubule diuretic and an osmotic diuretic; these properties are expected to lead to small blood pressure (BP) reductions. Clinical studies with dapagliflozin, canagliflozin, empagliflozin, ipragliflozin, luseogliflozin, and tofogliflozin used either as monotherapy or add-on therapy and compared with placebo or active treatment have also examined the effect of these agents on BP as a secondary endpoint. Although with some differences between individual agents, all of the approved SGLT-2 inhibitors provided a mild but meaningful reduction in office SBP and DBP. Recent studies with the use of ambulatory blood pressure monitoring suggest that the magnitude of this BP reduction can be even greater. The aim of this review is to systematically summarize and present the studies reporting the effect of approved SGLT-2 inhibitors on BP. PMID:26372321

  11. Insulin therapy for blood glucose fluctuation in diabetes%糖尿病血糖波动的胰岛素治疗

    Institute of Scientific and Technical Information of China (English)

    张新霞; 童南伟

    2009-01-01

    For different individuals with diabetes,blood glucose control varies. In the blood glucose controlling,blood glucose levels are sometimes higher than the target, sometimes the diabetic patients may develop hypoglycemia. In insulin therapy for blood glucose fluctuations, the most important thing is to avoid hypoglycemia. Finding out regular patterns of blood glucose fluctuations,then according to that,we need to choose the right insulin preparations to treat the condition. For the patients with irregular fluctuations of blood glucose,insulin pump therapy should be a proper choice.%血糖控制因人而异.在血糖控制中,血糖水平有时会明显高于靶目标,有时会发生低血糖.胰岛素干预血糖波动最重要的是不发生低血糖.摸清血糖波动的规律,依据血糖波动情况选择合理的胰岛素制剂.对于无规律的血糖波动等情况宜选择胰岛素泵(CSII)治疗.

  12. Comparing the Effect of a Single-Session Aerobic and Resistance Exercise on Blood Glucose in Women with Type 2 Diabetes

    Directory of Open Access Journals (Sweden)

    A Ravasi

    2012-01-01

    Full Text Available Introduction: Type 2 diabetes is a common disease in the world. Exercise has consistently been shown to improve glucose control. The purpose of this study was to compare the effect of a single-session aerobic and resistance exercise on blood glucose in women with type 2 diabetes. Methods: Twenty four women with type 2 diabetes were voluntarily and randomly selected and divided into aerobic exercise, resistance exercise and control groups. Aerobic exercise(rhythmic exercise was performed for 40 min at 60% HRmax and resistance exercise(weight lifting for 40 min utilizing 60% of 1-RM. Blood samples were collected before and after exercise. Results: Results of paired sample t-test showed a single-session aerobic and resistance exercise significantly decreased blood glucose(p<0.05. ANOVA test found a significant difference in blood glucose among three groups(p<0.05. Conclusion: A single-session aerobic and resistance exercise could decrease blood glucose in women with type 2 diabetes. However, a single-session aerobic exercise is more effective than resistance exercise on decreasing blood glucose.

  13. EVALUATION OF THE EFFECT OF “WAKOUBA '' ON THE LIPID PROFILE, SYSTOLIC BLOOD PRESSURE (SBP DIASTOLIC (DBP AND BLOOD GLUCOSE IN HYPERTENSIVE RABBITS

    Directory of Open Access Journals (Sweden)

    Tiekpa Wawa J

    2014-11-01

    Full Text Available This study aims at evaluating the effects of Wakouba, an extract of the fronds of oil palm tree Elaeis guineensis (Jacq traditionally used in the treatment of high blood pressure, on lipid profile, urea, creatinine, blood glucose, systolic blood pressure (SBP, diastolic (DBP and heart rate (HR in hypertensive rabbits. Methods: Twenty four rabbits (24 divided into six (06 groups of four rabbits each weighing between 1.5 ±3.0 to 2± 1.5 kg were used. Group 1 served as witness, group 2 sick and untreated control, groups 3, 4, 5, and 6 were used as experimental groups (sick+treatment. Throughout the experiment the witness group received distilled water; adrenaline was administered to the sick control group. After 10 days of adrenaline injection, hypertension has been stabilized in sick groups (group 2 to 6 and blood was taken for the determination of urea, creatinine, and lipids. Four (04 of the five (05 groups of hypertensive rabbits were treated with two (2 doses of " Wakouba " 950 and 2500 mg / kg bw and two ( 02 doses of ténordate 10 and 20 mg / kg BW, two(2 group by two(2 group . After ten (10 days of treatment, the SBP and DBP and HR were measured, blood was collected for determination of the same biochemical parameters. Results: The study of the effect of Wakouba and ternodate on the changes in systolic blood pressure SBP, DBP and heart rate (HR showed a significant decrease (P up to normalization of these parameters after 10 days of treatment. Similarly, the measurement of serum lipid profile in hypertensive rabbits treated with Wakouba (950mg / kg bw and tenordate (20 mg / kg bw showed a significant reduction in (P values of total cholesterol, LDL cholesterol and triglycerides in contrast to HDL cholesterol which has increased significantly compared to the control group. Same doses also normalize serum glucose, urea and creatinine. Histological sections performed on the kidney and the heart of hypertensive rabbit showed congestion of

  14. Blood-brain transport of new glucose analogs and their effect on yeast hexokinase

    International Nuclear Information System (INIS)

    Dihalogen derivates of D-glucal were formed by the direct addition of halogen to the unsaturated double-bond between C atoms 1 and 2 in D-glucal. 82Br-glucal and 36Cl-glucal were injected into the carotid artery of rats and brain uptake studied and compared with uptake for D-glucose and 2-deoxy-D-glucose. Investigations with enzymes have shown D-glucal dihalides to be good substrates for hexokinase. (U.K.)

  15. Melatonin Signaling Controls the Daily Rhythm in Blood Glucose Levels Independent of Peripheral Clocks

    OpenAIRE

    Owino, Sharon; Contreras-Alcantara, Susana; Baba, Kenkichi; Tosini, Gianluca

    2016-01-01

    Melatonin is rhythmically secreted by both the pineal gland and retina in a circadian fashion, with its peak synthesis occurring during the night. Once synthesized, melatonin exerts its effects by binding to two specific G-protein coupled receptors–melatonin receptor type 1(MT1) and melatonin receptor type 2(MT2). Recent studies suggest the involvement of MT1 and MT2 in the regulation of glucose homeostasis; however the ability of melatonin signaling to impart timing cues on glucose metabolis...

  16. Self-Reported Discrimination, Diabetes Distress, and Continuous Blood Glucose in Women with Type 2 Diabetes

    OpenAIRE

    Wagner, Julie A.; Tennen, Howard; Feinn, Richard; Osborn, Chandra Y

    2015-01-01

    We investigated whether self-reported racial discrimination was associated with continuous glucose levels and variability in individuals with diabetes, and whether diabetes distress mediated these associations. Seventy-four Black and White women with type 2 diabetes completed the Experience of Discrimination scale, a measure of lifetime racial discrimination, and the Problem Areas in Diabetes, a measure of diabetes distress. Participants wore a continuous glucose monitor for 24 h after 8 h of...

  17. The postprandial blood glucose concentration : as influenced by some changes in type and amount of carbohydrate in the meal and by post meal slow walking

    OpenAIRE

    2012-01-01

    Background The burden of obesity, type 2 diabetes (T2D) and cardio-vascular diseases (CVD) is rapidly increasing worldwide. Impaired glucose tolerance (IGT), in which the blood glucose level is higher than normal but not as high as in diabetes, is also a major public health problem. People with IGT have a higher risk of developing T2D and CVD, and especially the magnitude and duration of the postprandial blood glucose concentration (PPG) seems of crucial importance. In Norway, immigrants from...

  18. Effect of insulin in combination with selenium on blood glucose and GLUT4 expression in skeletal muscle of streptozotocin-induced diabetic rats

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    Objective To evaluate the effect of low-dose insulin [1 U/(kg·d)] in combination with selenium [180 g/(kg·d)] on general physiological parameters and glucose transporter (GLUT4) level in skeletal muscle of streptozotocin (STZ)-induced diabetic rats. Methods Diabetic rats were treated with insulin,selenium,and insulin and selenium in combination for four weeks. The level of blood glucose was determined using One Touch SureStep Blood Glucose meter and the level of GLUT4 in skeletal muscle was examined by immu...

  19. Aliskiren in combination with losartan reduces albuminuria independent of baseline blood pressure in patients with type 2 diabetes and nephropathy

    DEFF Research Database (Denmark)

    Persson, Frederik; Lewis, Julia B; Lewis, Edmund J;

    2011-01-01

    Elevated BP contributes to development and progression of proteinuria and decline in renal function in patients with type 2 diabetes. Our post hoc analysis assessed the baseline BP influence on the antiproteinuric effect in the Aliskiren in the Evaluation of Proteinuria in Diabetes (AVOID) study....

  20. A sodium-glucose co-transporter 2 inhibitor empagliflozin prevents abnormality of circadian rhythm of blood pressure in salt-treated obese rats.

    Science.gov (United States)

    Takeshige, Yui; Fujisawa, Yoshihide; Rahman, Asadur; Kittikulsuth, Wararat; Nakano, Daisuke; Mori, Hirohito; Masaki, Tsutomu; Ohmori, Koji; Kohno, Masakazu; Ogata, Hiroaki; Nishiyama, Akira

    2016-06-01

    Studies were performed to examine the effects of the selective sodium-glucose co-transporter 2 (SGLT2) inhibitor empagliflozin on urinary sodium excretion and circadian blood pressure in salt-treated obese Otsuka Long Evans Tokushima Fatty (OLETF) rats. Fifteen-week-old obese OLETF rats were treated with 1% NaCl (in drinking water), and vehicle (0.5% carboxymethylcellulose, n=10) or empagliflozin (10 mg kg(-1)per day, p.o., n=11) for 5 weeks. Blood pressure was continuously measured by telemetry system. Glucose metabolism and urinary sodium excretion were evaluated by oral glucose tolerance test and high salt challenge test, respectively. Vehicle-treated OLETF rats developed non-dipper type blood pressure elevation with glucose intolerance and insulin resistance. Compared with vehicle-treated animals, empagliflozin-treated OLETF rats showed an approximately 1000-fold increase in urinary glucose excretion and improved glucose metabolism and insulin resistance. Furthermore, empagliflozin prevented the development of blood pressure elevation with normalization of its circadian rhythm to a dipper profile, which was associated with increased urinary sodium excretion. These data suggest that empagliflozin elicits beneficial effects on both glucose homeostasis and hypertension in salt-replete obese states. PMID:26818652

  1. Sepsis does not alter red blood cell glucose metabolism or Na+ concentration: A 2H-, 23Na-NMR study

    International Nuclear Information System (INIS)

    The effects of sepsis on intracellular Na+ concentration ([Na+]i) and glucose metabolism were examined in rat red blood cells (RBCs) by using 23Na- and 2H-nuclear magnetic resonance (NMR) spectroscopy. Sepsis was induced in 15 halothane-anesthetized female Sprague-Dawley rats by using the cecal ligation and perforation technique; 14 control rats underwent cecal manipulation without ligation. The animals were fasted for 36 h, but allowed free access to water. At 36 h postsurgery, RBCs were examined by 23Na-NMR by using dysprosium tripolyphosphate as a chemical shift reagent. Human RBCs from 17 critically ill nonseptic patients and from 7 patients who were diagnosed as septic were also examined for [Na+]i. Five rat RBC specimens had [Na+]i determined by both 23Na-NMR and inductively coupled plasma-atomic emission spectroscopy (ICP-AES). For glucose metabolism studies, RBCs from septic and control rats were suspended in modified Krebs-Henseleit buffer containing [6,6-2H2]glucose and examined by 2H-NMR. No significant differences in [Na+]i or glucose utilization were found in RBCs from control or septic rats. There were no differences in [Na+]i in the two groups of patients. The [Na+]i determined by NMR spectroscopy agreed closely with measurements using ICP-AES and establish that 100% of the [Na+]i of the RBC is visible by NMR. Glucose measurements determined by 2H-NMR correlated closely (correlation coefficient = 0.93) with enzymatic analysis. These studies showed no evidence that sepsis disturbed RBC membrane function or metabolism

  2. Diminished insulin-mediated forearm blood flow and muscle glucose uptake in young men with low birth weight

    DEFF Research Database (Denmark)

    Sonne, M P; Højbjerre, L; Alibegovic, A C; Vaag, A; Stallknecht, B; Dela, F

    2009-01-01

    BACKGROUND: Low birth weight (LBW) is associated with increased risk of type 2 diabetes and cardiovascular disease. We studied endothelial function and insulin sensitivity in young men with LBW (n = 22) and controls (n = 22). METHODS: Insulin sensitivity and endothelial function was studied with...... venous occlusion plethysmography and intra-arterial infusions of adenosine and acetylcholine, before and during a hyperinsulinemic isoglycemic clamp. RESULTS: Forearm blood flow response to systemic hyperinsulinemia was diminished in LBW compared to controls (p < 0.05). Fractional arteriovenous glucose...

  3. Effect of oral administration of bark extracts of Pterocarpus santalinus L. on blood glucose level in experimental animals.

    Science.gov (United States)

    Kameswara Rao, B; Giri, R; Kesavulu, M M; Apparao, C

    2001-01-01

    The effect of administration of different doses of Pterocarpus santalinus L. bark extracts in normal and diabetic rats, on blood glucose levels was evaluated in this study. Among the three fractions (aqueous, ethanol and hexane), ethanolic fraction at the dose of 0.25 g/kg body weight showed maximum antihyperglycemic activity. The same dose did not cause any hypoglycemic activity in normal rats. The results were compared with the diabetic rats treated with glibenclamide and the antihyperglycemic activity of ethanolic extract of PS bark at the dose of 0.25 g/kg b.w. was found to be more effective than that of glibenclamide. PMID:11137350

  4. Effects of Electroacupuncture at Weiwanxiashu and Zusanli Points on Blood Glucose and Plasma Pancreatic Glucagon Contents in Diabetic Rabbits

    Institute of Scientific and Technical Information of China (English)

    曾志勇; 李永义

    2002-01-01

    The Effects of electroacupuncture (EA) at Weiwanxiashu (EX-B3) and Zusanli (ST 36) points on blood glucose (BG) and plasma pancreatic glucagon (PG) contents were dynamically observed in diabetic rabbits induced by Alloxan. It is found that acupuncture at Weiwanxiashu point can significantly lower the BG content and inhibit release of PG; no significant changes in BG and PG are found when acupuncture is given at Zusanli (ST 36) point alone, however BG and PG contents decrease more obviously when acupuncture employed at both Zusanli and Weiwanxiashu, suggesting that Zusanli has a marked synergetic action with Weiwanxiashu.

  5. The juice of fresh leaves of Catharanthus roseus Linn. reduces blood glucose in normal and alloxan diabetic rabbits

    OpenAIRE

    Lodagala Srinivas D; Boini Murthy K; Nammi Srinivas; Behara Ravindra Babu S

    2003-01-01

    Abstract Background The leaf juice or water decoction of Catharanthus roseus L. (Apocyanaceae) is used as a folk medicine for the treatment of diabetes all over the world. In the present investigation, the leaf juice of C. roseus has been evaluated for its hypoglycemic activity in normal and alloxan-induced diabetic rabbits. Methods The blood glucose lowering activity of the leaf juice was studied in normal and alloxan-induced (100 mg/kg, i.v.) diabetic rabbits, after oral administration at d...

  6. The Effect of Family-centered Care on Management of Blood Glucose Levels in Adolescents with Diabetes

    OpenAIRE

    Cheraghi, Fatemeh; Shamsaei, Farshid; Mortazavi, Sayyedeh Zohreh; Moghimbeigi, Abbas

    2015-01-01

    Background Responsibility for diabetes management tasks must shift from caregivers to adolescents as adolescents grow older. Also, family-centered care is a way to provide efficient care for them at home. This study aimed to identify the effect of family-centered care on management of blood glucose levels in adolescents with type 1 diabetes mellitus (T1DM). Methods This is a Pre-experimental study with a pre- and post-test design. The participants consisted of forty adolescents with T1DM, age...

  7. Second-meal effects of pulses on blood glucose and subjective appetite following a standardized meal 2 h later.

    Science.gov (United States)

    Mollard, Rebecca C; Wong, Christina L; Luhovyy, Bohdan L; Cho, France; Anderson, G Harvey

    2014-07-01

    This study investigated whether pulses (chickpeas, yellow peas, navy beans, lentils) have an effect on blood glucose (BG) and appetite following a fixed-size meal 2 h later. Over the following 2 h, all pulses lowered BG area under the curve (AUC) and lentils reduced appetite AUC compared with white bread (p < 0.05). Following the meal, BG was lower after lentils and chickpeas at 150 and 165 min, and AUC was lower after lentils compared with white bread (p < 0.05). PMID:24797207

  8. What is the optimal blood glucose target in critically ill patients? A nested cohort study

    Directory of Open Access Journals (Sweden)

    Ashraf Al-Tarifi

    2011-01-01

    Full Text Available Aims: There is an uncertainty about what constitutes an optimal level of blood glucose (BG in critically ill patients. The objective of this study is to identify the optimal BG target for glycemic control in critically ill patients that is associated with survival benefit with the least hypoglycemia risk. Setting and Design: This is a nested cohort study within a randomized control trial conducted in a tertiary care center in King Abdulaziz Medical City, Riyadh, Kingdom of Saudi Arabia. Methods: The study was carried out in a single center to assess the effect of intensive insulin therapy [IIT; target BG 4.4-6.1 mmol/L (80-110 mg/dL] versus conventional insulin therapy [CIT; target BG 10-11.1 mmol/L (180-200 mg/dL] in a medical/surgical ICU. All patients were divided into six groups based on the mean daily BG levels. A logistic regression model was used to determine the association of BG and ICU mortality. We compared different outcomes below and above different BG thresholds of 0.1 mmol/L (2 mg/dL increments using multivariate analyses. Statistical Analysis: Data are presented as mean ± SD or median with interquartile ranges, unless otherwise indicated. Differences between the six groups were assessed using the c΂ test. A P-value equal or less than 0.05 was considered to indicate statistical significance. The results were expressed as adjusted odds ratio (aOR and 95% confidence intervals (CI. Statistical analyses were carried out using the Statistical Analysis Software (SAS, release 8, SAS Institute Inc., Cary, NC, USA. Results: Among six groups, the ICU mortality was least in patients with BG <8.7 mmol/L (<157 mg/dL compared with patients with BG ≥8.7 mmol/L (≥157 mg/dL [11.5% vs. 21.5%, P = 0.002]. When analyzed using 0.1 mmol increments in average BG, we found that mortality remained unchanged by increasing thresholds of BG up to 8.0 mmol/L (144 mg/dL and started to rise with thresholds of BG of 8.1 mmol/L (146 mg/dL and above. The

  9. Practice of standardized management of the portable blood glucose meter%便携式血糖仪的规范化管理实践

    Institute of Scientific and Technical Information of China (English)

    常玉锋

    2014-01-01

    Objective: To apply the norms of the portable blood glucose meter in clinic and improve the quality and level of blood glucose detection. Methods:The management organization of the portable blood glucose meter was established. The organization understudied the working principles and the advantages and disadvantages of blood glucose meter. The model of the portable blood glucose meter was unified in a medical unit. The performance of the portable blood glucose meter and the biochemical analyzer was compared. The organization established standard operating procedures, strengthen personnel training. The clinical staff takes quality control regular. Results:The qualified rate of the use, the maintenance and the results detection was increased. Conclusion:The standardized management system guarantees the detection result of the portable blood glucose meter.%目的:规范便携式血糖仪在临床中的应用,提高血糖检测质量和检测水平。方法:成立统一的便携式血糖仪管理小组,同一医疗单元的便携式血糖仪统一型号,并进行全面的生化比对分析,使用中制定统一的标准操作规程,加强使用人员的培训,定期进行室内及室间质控。结果:医院人员的便携式血糖仪知识掌握率、操作使用合格率及结果检查合格率均大幅上升。结论:规范的管理体系为便携式血糖仪检测结果的可靠性提供了保障。

  10. Effects of previous protein intake on rectal temperature, blood glucose, plasma thyroid hormone and minerals by laying hens during a forced molt

    International Nuclear Information System (INIS)

    The effects of forced molting on blood glucose, rectal temperature, plasma T4, T3 and minerals were studied in hens previously fed rations with different protein contents (14, 17 and 20% crude protein). Blood samples were obtained from brachial veins for blood glucose, T4 and T3 were measured by radioimmunoassay, and plasma minerals were determined by atomic absorption spectroscopy. Blood glucose and rectal temperature were reduced during fasting regardless of previous protein intake. Pre molting T4 plasma level was higher in laying hens fed higher protein ration, but feed deprivation reduced T4 and T3 concentrations irrespective of protein intake, except T4 level for 14% crude protein fed birds that increased during fasting. The data obtained in this experiment suggest that previous protein intake does not interfere with the metabolic changes during forced molt. (author). 19 refs, 1 fig, 4 tabs

  11. Optimizing insulin injection technique and its effect on blood glucose control

    Directory of Open Access Journals (Sweden)

    Giorgio Grassi, MD

    2014-12-01

    Conclusions: Targeted individualized training in IT, including the switch to a 4 mm needle, is associated with improved glucose control, greater satisfaction with therapy, better and simpler injection practices and possibly lower consumption of insulin after only a three month period.

  12. Effect of meals with varying glycemic index on blood glucose response in type 2 diabetes mellitus

    Directory of Open Access Journals (Sweden)

    Maulik S. Nayak

    2016-08-01

    Conclusions: It was concluded in the study that Plasma Glucose shows a positive response to high GI foods and this may aggravate the hyperglycemia already present in Type 2 DM. Low GI diets may be helpful in reducing risks related to Type 2 DM. [Int J Res Med Sci 2016; 4(8.000: 3444-3448

  13. [Effect of a dehydrated extract of nopal (Opuntia ficus indica Mill.) on blood glucose].

    Science.gov (United States)

    Frati-Munari, A C; de León, C; Ariza-Andraca, R; Bañales-Ham, M B; López-Ledesma, R; Lozoya, X

    1989-01-01

    To assess if a dehydrated extract of nopal stems retains the effect on glycemia of the entire nopal stems two experiments were performed. A. Six patients with type II diabetes mellitus in fasting condition received 30 capsules containing 10.1 +/- 0.3 g of the extract, and serum glucose levels were measured hourly from 0 to 180 minutes. B. Six healthy volunteers received 30 capsules with the extract followed by 74 g of dextrose orally. Serum glucose measurements were made in a similar fashion. In each experiment a control test with empty capsules was performed. Nopal extract did not reduce fasting glycemia in diabetic subjects. Nevertheless, the extract diminished the increase of serum glucose which followed a dextrose load. Peak serum glucose was 20.3 +/- 18.2 mg/dl (X +/- SD) lower in the test with nopal than in the control one (P less than 0.025). Dehydrated extract of nopal (Opuntia ficus-indica Mill) did not show acute hypoglycemic effect, although could attenuate postprandial hyperglycemia. PMID:2561256

  14. Diabetes Numeracy and Blood Glucose Control: Association With Type of Diabetes and Source of Care

    OpenAIRE

    Zaugg, Stephanie D.; Dogbey, Godwin; Collins, Karen; Reynolds, Sharon; Batista, Carter; Brannan, Grace; Shubrook, Jay H.

    2014-01-01

    Limited diabetes numeracy may be an important factor affecting diabetes care and treatment adherence. This study assessed the relationship between the Diabetes Numeracy Test (DNT-15 score) and patient and treatment variables. Patients who had type 1 diabetes and those who received care from specialty centers had higher levels of numeracy, but this did not translate into improved glucose control.

  15. Chronic obstructive pulmonary disease and blood glucose%慢性阻塞性肺疾病和血糖

    Institute of Scientific and Technical Information of China (English)

    高惠丽; 姚婉贞

    2008-01-01

    To analyze Chinese and foreign advancement documents recently published for the association between chronic obstructive pulmonary disease(COPD) and blood glucose. COPD and asthma influenced differently with glucose. COPD patients are discussed with changes such as inflammatory factor,erythrocyte alterations,glucose metabolism, hypoxemia, dyscrasia ect. Hyperglycaemia more emerges with in COPD patients than other patients. Hyperglycaemia is a risk factor of acute exacerbation COPD.%分析近期发表的中外文献,研究慢性阻塞性肺疾病(chronic obstructive pulmonary disease,COPD)和血糖的相互关系.COPD和支气管哮喘对血糖的不同影响.COPD患者中炎症因子、红细胞改变、葡萄糖的代谢、低氧血症和恶液质等改变进行论证,阐明COPD易出现高血糖.高血糖是COPD急性加重的独立危险因素之一.

  16. Transforming the blood glucose meter into a general healthcare meter for in vitro diagnostics in mobile health.

    Science.gov (United States)

    Lan, Tian; Zhang, Jingjing; Lu, Yi

    2016-01-01

    Recent advances in mobile network and smartphones have provided an enormous opportunity for transforming in vitro diagnostics (IVD) from central labs to home or other points of care (POC). A major challenge to achieving the goal is a long time and high costs associated with developing POC IVD devices in mobile Health (mHealth). Instead of developing a new POC device for every new IVD target, we and others are taking advantage of decades of research, development, engineering and continuous improvement of the blood glucose meter (BGM), including those already integrated with smartphones, and transforming the BGM into a general healthcare meter for POC IVDs of a wide range of biomarkers, therapeutic drugs and other analytical targets. In this review, we summarize methods to transduce and amplify selective binding of targets by antibodies, DNA/RNA aptamers, DNAzyme/ribozymes and protein enzymes into signals such as glucose or NADH that can be measured by commercially available BGM, making it possible to adapt many clinical assays performed in central labs, such as immunoassays, aptamer/DNAzyme assays, molecular diagnostic assays, and enzymatic activity assays onto BGM platform for quantification of non-glucose targets for a wide variety of IVDs in mHealth. PMID:26946282

  17. Clinical trial of Cecropia obtusifolia and Marrubium vulgare leaf extracts on blood glucose and serum lipids in type 2 diabetics.

    Science.gov (United States)

    Herrera-Arellano, A; Aguilar-Santamaría, L; García-Hernández, B; Nicasio-Torres, P; Tortoriello, J

    2004-11-01

    Cecropia obtusifolia and Marrubium vulgare have been widely used in Mexican traditional medicine for the control of type 2 diabetes. In order to evaluate the clinical effect produced by the aqueous extract from these species on type 2 non-controlled diabetes mellitus, a total of 43 outpatients were included. Based on the European NIDDM (policy group) criteria, only patients with poor response to the conventional treatment were selected. All patients maintained their medical treatment and also received a prepared infusion of the dry leaves of the plant treatment for 21 days. In a double-blind manner, the patients were randomly grouped as follows: 22 patients were treated with C. obtusifolia and 21 with M. vulgare. The fasting blood glucose values were reduced by 15.25% on patients treated with C. obtusifolia, while cholesterol and triglycerides were decreased by 14.62% and 42.0%, respectively (ANOVA pvulgare, the plasma glucose level was reduced by 0.64% and cholesterol and triglycerides by 4.16% and 5.78%, respectively. When the results were compared between groups, significant differences in glucose and cholesterol diminution were found. The obtained results showed that the infusion prepared with the leaves of C. obtusifolia (containing 2.99+/-0.14mg of chlorogenic acid/g of dried plant) produced beneficial effects on carbohydrate and lipid metabolisms when it was administered as an adjunct on patients with type 2 diabetes with poor response to conventional medical treatment. PMID:15636168

  18. Reduction of the interferences of biochemicals and hematocrit ratio on the determination of whole blood glucose using multiple screen-printed carbon electrode test strips.

    Science.gov (United States)

    Lin, Yueh-Hui; Shen, Thomas Y; Chang, C Allen

    2007-11-01

    A practical approach to reduce the interferences of biochemicals and hematocrit ratio (Hct%) in the determination of whole blood glucose using multiple screen-printed carbon electrode (SPCE) test strips is described. SPCE test strips with and without glucose oxidase [i.e., GOD(+)-SPCEs and GOD(-)-SPCEs] were used and the chronoamperometric currents of test glucose solutions with various spiked uric acid concentrations and Hct% were measured. By establishing the interference relationships between glucose concentrations and uric acid concentrations as well as Hct% values and with appropriate corrections, the whole blood glucose determinations could be made to be more accurate and comparable to those determined by the reference YSI method. Specifically, the use of the DeltaI value, i.e., the current difference between GOD(+)-SPCE and GOD(-)-SPCE measurements, would reduce most of the uric acid/biochemical interferences. An interpolation method was also established to correct for the glucose determinations with Hct% interferences. The Hct% corrections using the interpolation method are especially important and necessary for those blood samples with glucose concentrations higher than 110 mg dL(-1) and Hct% values lower than 35%. This approach should also be applicable to other biochemical determinations using similar electrochemical techniques. PMID:17912503

  19. Physical and mathematical aspects of blood-glucose- and insulin-level kinetics in patients with coronary heart disease and high risk of its development

    Science.gov (United States)

    Denisova, Tatyana P.; Malinova, Lidia I.; Malinov, Igor A.

    2001-05-01

    The intravenous glucose tolerance test was performed to estimate the kinetics of blood glucose and insulin levels. Glucose was injected in individual standardized dose (0.5 g. per 1 kg of body weight). Three groups of patients were checked up: 1) patients with coronary heart disease verified by cicatricial alterations in myocardium found by electrocardiographic and echocardiographic methods; 2) children of patients with transmural myocardial infarction practically healthy at the moment of study; 3) persons practically healthy at the moment of study without any indications on cardiovascular diseases and non-insulin dependent diabetes mellitus among all ancestors and relatives who frequently were long-livers. Last groups didn't differ by age and sex. Peripheral blood glucose level, immunoreactive and free insulin (tested by muscular tissue) were studied just before glucose injection (on an empty stomach) and 4 times after it. The received discrete data were approximated by high degree polynomials, the estimation of blood glucose and insulin time functions symmetric was performed. The deceleration of degradation of insulin circulating in peripheral blood and the time decrease of second phase of insulin secretion were analytically established. This fact proves the complicated mechanism of insulin alterations in atherosclerosis, consisting not only of insulin resistance of peripheral tissues but of decrease of plastic processes in insulin- generating cells.

  20. Oligosaccharide and Creatine Supplementation on Glucose and Urea Nitrogen in Blood and Serum Creatine Kinase in Basketball Athletes

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

    The effects of oligosaccharide and creatine (Cr) supplementation on glucose, lactic acid and urea nitrogen levels in blood and activity of serum creatine kinase (CK) were explored. Twenty CUBA male athletes were divided into 4 groups: group A (supplementation of Cr alone), group B (supplementation of oligosaccharide), group C (supplementation of oligosaccharide and Cr) and group D (placebo control group). By using orthogonal L4 table (23), the experiment was performed. There were factors including oligosaccharide (carbohydrate, CHO), Cr and their correlation. Each factor had two levels: supplementation and no-supplementation. The results showed that the supplementation of CHO or Cr alone, combined supplementation of CHO and Cr could significantly reduce the glucose, urea nitrogen levels in blood and serum CK activity after competition in the athletes. Moreover, the effects of combined supplementation of CHO and Cr were more satisfactory. It was concluded that supplementation of CHO and Cr could promote the recovery of physical performance and athletic abilities after athletics in basketball athletes.