WorldWideScience

Sample records for based beam control

  1. Beam based systems and controls

    CERN Document Server

    Jacquet, D

    2012-01-01

    This presentation will give a review from the operations team of the performance and issues of the beam based systems, namely RF, ADT, beam instrumentation, controls and injection systems. For each of these systems, statistics on performance and availability will be presented with the main issues encountered in 2012. The possible improvements for operational efficiency and safety will be discussed, with an attempt to answer the question "Are we ready for the new challenges brought by the 25ns beam and increased energy after LSI? ".

  2. Implementation of EPICS based Control System for Radioisotope Beam line

    International Nuclear Information System (INIS)

    Kim, Jae-Ha; Ahn, Tae-Sung; Song, Young-Gi; Kwon, Hyeok-Jung; Cho, Yong-Sub

    2015-01-01

    Korea Mult-purpose Accelerator Complex (KOMAC) has been operating 100 MeV proton linear accelerator . For operating 100 MeV linac, various control system has been implemented such as vacuum, power supply, RCCS and etc. KOMAC is operating two beam lines so that clients can use 100 MeV proton beam for their experiment. KOMAC sends beam to beam line and target room using two dipole magnets and several quadrupole magnets. As demand for experiments and Radius Isotope using beam is increased, another beam line is under construction and RI beam line control system is need. To synchronize with KOMAC control system, RI beam line control system is based on Experimental Physics and Industrial control System (EPICS) software. The beam is transported to RI beam line to control magnet power supply and vacuum. Implementation of RI beam line control system is presented and some preliminary results are reported. The base RI beam line control system is implemented. It can control beam direction and vacuum. Comparing archived data and current data, RI beam line and control system will be improved. In the future, scroll pump and gate control system will be implemented using programmable logic controller PLC. RI beam interlock sequence will be added to KOMAC interlock system to protect linac

  3. Beam closed orbit feedback based on PID control

    International Nuclear Information System (INIS)

    Xuan Ke; Wang Lin; Liu Gongfa; Li Weimin; Li Chuan; Wang Jigang; Bao Xun; Xu Hongliang

    2013-01-01

    The algorithm in the feedback system has important influence on the performance of the beam orbit. Good feedback algorithm can greatly improve the beam orbit stability. In this paper, the theory of beam closed orbit correction, the principle of PID control and the beam closed orbit feedback correction using PID control were introduced. The simulation results were given. Compared with least-square method, the PID feedback algorithm makes the steady-state error smaller and more accurate, and enhances the beam orbit stability. (authors)

  4. Fuzzy-logic-based active vibration control of beams using piezoelectric patches

    Science.gov (United States)

    Sharma, Manu; Singh, S. P.; Sachdeva, B. L.

    2003-10-01

    The present work presents a fuzzy logic based controller with a compact rule base, for active vibration control of beams. The controller was implemented experimentally on a test beam and the results were found satisfactory. The test system consists of a cantilevered beam with two piezoelectric patches mounted near its root in collocated fashion. This piezo-beam system was modelled using Finite Element Method. To derive the equations of motion, Hamilton's principle was used. Electro-mechanical interaction of the piezoelectric patch with the beam was modelled using linear constitutive equations for piezoceramics, which relate strain and electric displacement to stress and electric field. The fuzzy logic controller is based on modal velocity of the beam. The basis for generating the fuzzy logic rule base of this controller is obtained from negative velocity feedback control. Modal velocity of the beam acts as an input to the fuzzy controller and actuation force is the output from the inference engine. Linear decay of vibratory amplitude is observed in case of fuzzy logic controller as opposed to logarithmic decay in case of negative velocity feedback control Present controller has just three rules. This is an important achievement because bulky fuzzy logic controllers for active vibration control require fast processors for real time implementation (Kwak and Sciulli and Mayhan and Washington).

  5. Beam Techniques - Beam Control and Manipulation

    Energy Technology Data Exchange (ETDEWEB)

    Minty, Michiko G

    2003-04-24

    We describe commonly used strategies for the control of charged particle beams and the manipulation of their properties. Emphasis is placed on relativistic beams in linear accelerators and storage rings. After a brief review of linear optics, we discuss basic and advanced beam control techniques, such as transverse and longitudinal lattice diagnostics, matching, orbit correction and steering, beam-based alignment, and linac emittance preservation. A variety of methods for the manipulation of particle beam properties are also presented, for instance, bunch length and energy compression, bunch rotation, changes to the damping partition number, and beam collimation. The different procedures are illustrated by examples from various accelerators. Special topics include injection and extraction methods, beam cooling, spin transport and polarization.

  6. Neutral particle beam intensity controller

    Science.gov (United States)

    Dagenhart, W.K.

    1984-05-29

    The neutral beam intensity controller is based on selected magnetic defocusing of the ion beam prior to neutralization. The defocused portion of the beam is dumped onto a beam dump disposed perpendicular to the beam axis. Selective defocusing is accomplished by means of a magnetic field generator disposed about the neutralizer so that the field is transverse to the beam axis. The magnetic field intensity is varied to provide the selected partial beam defocusing of the ions prior to neutralization. The desired focused neutral beam portion passes along the beam path through a defining aperture in the beam dump, thereby controlling the desired fraction of neutral particles transmitted to a utilization device without altering the kinetic energy level of the desired neutral particle fraction. By proper selection of the magnetic field intensity, virtually zero through 100% intensity control of the neutral beam is achieved.

  7. A rule-based computer control system for PBX-M neutral beams

    International Nuclear Information System (INIS)

    Frank, K.T.; Kozub, T.A.; Kugel, H.W.

    1987-01-01

    The Princeton Beta Experiment (PBX) neutral beams have been routinely operated under automatic computer control. A major upgrade of the computer configuration was undertaken to coincide with the PBX machine modification. The primary tasks included in the computer control system are data acquisition, waveform reduction, automatic control and data storage. The portion of the system which will remain intact is the rule-based approach to automatic control. Increased computational and storage capability will allow the expansion of the knowledge base previously used. The hardware configuration supported by the PBX Neutral Beam (XNB) software includes a dedicated Microvax with five CAMAC crates and four process controllers. The control algorithms are rule-based and goal-driven. The automatic control system raises ion source electrical parameters to selected energy goals and maintains these levels until new goals are requested or faults are detected

  8. A Labview based FPGA data acquisition with integrated stage and beam transport control

    International Nuclear Information System (INIS)

    Laird, J.S.; Szymanski, R.; Ryan, C.G.; Gonzalez-Alvarez, I.

    2013-01-01

    We report on a new FPGA based data acquisition system developed for the CSIRO Nuclear Microprobe (NMP) which is tightly integrated with both target positioning and beam transport. The data acquisition system called MicrodaQ is based on National Instruments Labview FPGA and numerous instrumentation modules spread over several PC’s. Beam transport uses a feedback control loop to optimise current on target for long unmanned experiments. These upgrades are discussed in detail and an example of the systems use for μ-Particle Induced X-ray Emission (PIXE) analysis on a Doriri apatite is briefly described

  9. A Labview based FPGA data acquisition with integrated stage and beam transport control

    Science.gov (United States)

    Laird, J. S.; Szymanski, R.; Ryan, C. G.; Gonzalez-Alvarez, I.

    2013-07-01

    We report on a new FPGA based data acquisition system developed for the CSIRO Nuclear Microprobe (NMP) which is tightly integrated with both target positioning and beam transport. The data acquisition system called MicrodaQ is based on National Instruments Labview FPGA and numerous instrumentation modules spread over several PC's. Beam transport uses a feedback control loop to optimise current on target for long unmanned experiments. These upgrades are discussed in detail and an example of the systems use for μ-Particle Induced X-ray Emission (PIXE) analysis on a Doriri apatite is briefly described.

  10. Cyclotron radiation beam control

    International Nuclear Information System (INIS)

    Dominke, P.

    1983-01-01

    This patent application describes an apparatus for attenuating a beam of particulate radiation comprising a series of modules, each module being constituted by a sphere having a passage, a cupola covering said sphere and a base supporting said sphere, and means for causing movement of the spheres for aligning said passages with an axis of a beam line and arranging said passages out of alignment so as to attenuate the beam. (author)

  11. Electron beam control for barely separated beams

    Energy Technology Data Exchange (ETDEWEB)

    Douglas, David R.; Ament, Lucas J. P.

    2017-04-18

    A method for achieving independent control of multiple beams in close proximity to one another, such as in a multi-pass accelerator where coaxial beams are at different energies, but moving on a common axis, and need to be split into spatially separated beams for efficient recirculation transport. The method for independent control includes placing a magnet arrangement in the path of the barely separated beams with the magnet arrangement including at least two multipole magnets spaced closely together and having a multipole distribution including at least one odd multipole and one even multipole. The magnetic fields are then tuned to cancel out for a first of the barely separated beams to allow independent control of the second beam with common magnets. The magnetic fields may be tuned to cancel out either the dipole component or tuned to cancel out the quadrupole component in order to independently control the separate beams.

  12. Symmetric grey box identification and distributed beam-based controller design for free-electron lasers

    International Nuclear Information System (INIS)

    Pfeiffer, Sven

    2014-09-01

    The European X-ray Free-Electron Laser (XFEL) at the Deutsches Elektronen Synchtrotron (DESY) in Hamburg will, starting in 2015, open up completely new research opportunities for scientist and industrial users by exploiting ultrashort X-ray laser pulses. Bunches of electrons are accelerated by a radio frequency field inside superconducting cavities up to an energy of 17.5 GeV. A periodic arrangement of magnets forces the accelerated electrons onto a tight slalom path leading to a process in that the electrons emit extremely short and intense X-ray flashes. The generation of equidistant X-ray flashes with a constant intensity requires an extremely high precision field control in combination with beam-based signals. FLASH, which can be seen as a pilot test facility, allows to develop and test controller concepts even before the European XFEL is in operation. In this thesis it is shown that a physical white box model structure, which describes the behavior of each subsystem within the radio frequency field control loop, obeys as first-order approximation the special orthogonal group of dimension two (SO(2)). Presented is a grey box identification approach, which combines the physical model structure with general identification methods. The accelerator modules are operated in a pulsed mode. Thus, the excitation of the system and therefore the identification of the input-output behavior is only possible within a short time period. Developed is an adaptive identification approach with a specified SO(2) symmetric model structure. The proposed controller design strategy fulfills the requirements of a high precision field performance. Adapting the feedforward signal by using an iterative learning control (ILC) algorithm reduces remaining repetitive field errors from pulse to pulse. It is shown, that exploiting the SO(2) symmetric structure and using the developed tensor based ILC representation simplifies the feedforward update computation. Magnetic chicanes, so

  13. A LabVIEWTM-based scanning and control system for proton beam micromachining

    International Nuclear Information System (INIS)

    Bettiol, Andrew A.; Kan, J.A. van; Sum, T.C.; Watt, F.

    2001-01-01

    LabVIEW TM is steadily gaining in popularity as the programming language of choice for scientific data acquisition and control. This is due to the vast array of measurement instruments and data acquisition cards supported by the LabVIEW TM environment, and the relative ease with which advanced software can be programmed. Furthermore, virtual instruments that are designed for a given system can be easily ported to other LabVIEW TM platforms and hardware. This paper describes the new LabVIEW TM based scanning and control system developed specifically for proton beam micromachining (PBM) applications. The new system is capable of scanning figures at 16-bit resolution with improved sub-microsecond scan rates. Support for electrostatic beam blanking and external dose normalization using a TTL signal have been implemented. The new software incorporates a semi-automated dose calibration system, and a number of novel dose normalization methods. Limitations of the current beam scanning hardware are discussed in light of new results obtained from micromachining experiments performed in SU-8 photoresist

  14. Development of EPICS based beam-line experimental control employing motor controller for precision positioning

    International Nuclear Information System (INIS)

    Tuli, Anupriya; Jain, Rajiv; Vora, H.S.

    2015-01-01

    In a Synchrotron Radiation Source the beamline experiments are carried out in radiation prone environment, inside the hutch, which demands to conduct experiments remotely. These experiments involves instrument control and data acquisition from various devices. Another factor which attributes to system complexity is precise positioning of sample and placement of detectors. A large number of stepper motors are engaged for achieving the required precision positioning. This work is a result of development of Experimental Physics and Industrial Control System (EPICS) based control system to interface a stepper motor controller developed indigenously by Laser Electronics Support Division of RRCAT. EPICS is an internationally accepted open source software environment which follows toolkit approach and standard model paradigm. The operator interface for the control system software was implemented using CSS BOY. The system was successfully tested for Ethernet based remote access. The developed control software comprises of an OPI and alarm handler (EPICS ALH). Both OPI and ALH are linked with PV's defined in database files. The development process resulted into a set of EPICS based commands for controlling stepper motor. These commands are independent of operator interface, i.e. stepper motor can be controlled by using these set of commands directly on EPICS prompt. This command set is illustrated in the above table. EPICS Alarm Handler was also tested independently by running these commands on EPIC prompt. If not using ALH, operator can read the alarm status of a PV using 'SEVR' and 'STAT' attributes. (author)

  15. General beam position controlling method for 3D optical systems based on the method of solving ray matrix equations

    Science.gov (United States)

    Chen, Meixiong; Yuan, Jie; Long, Xingwu; Kang, Zhenglong; Wang, Zhiguo; Li, Yingying

    2013-12-01

    A general beam position controlling method for 3D optical systems based on the method of solving ray matrix equations has been proposed in this paper. As a typical 3D optical system, nonplanar ring resonator of Zero-Lock Laser Gyroscopes has been chosen as an example to show its application. The total mismatching error induced by Faraday-wedge in nonplanar ring resonator has been defined and eliminated quite accurately with the error less than 1 μm. Compared with the method proposed in Ref. [14], the precision of the beam position controlling has been improved by two orders of magnitude. The novel method can be used to implement automatic beam position controlling in 3D optical systems with servo circuit. All those results have been confirmed by related alignment experiments. The results in this paper are important for beam controlling, ray tracing, cavity design and alignment in 3D optical systems.

  16. Integrated control system for electron beam processes

    Science.gov (United States)

    Koleva, L.; Koleva, E.; Batchkova, I.; Mladenov, G.

    2018-03-01

    The ISO/IEC 62264 standard is widely used for integration of the business systems of a manufacturer with the corresponding manufacturing control systems based on hierarchical equipment models, functional data and manufacturing operations activity models. In order to achieve the integration of control systems, formal object communication models must be developed, together with manufacturing operations activity models, which coordinate the integration between different levels of control. In this article, the development of integrated control system for electron beam welding process is presented as part of a fully integrated control system of an electron beam plant, including also other additional processes: surface modification, electron beam evaporation, selective melting and electron beam diagnostics.

  17. Feedback control of laser welding based on frequency analysis of light emissions and adaptive beam shaping

    Czech Academy of Sciences Publication Activity Database

    Mrňa, Libor; Šarbort, Martin; Řeřucha, Šimon; Jedlička, Petr

    2012-01-01

    Roč. 39, NOV (2012), s. 784-791 ISSN 1875-3892. [LANE 2012. Laser Assisted Net Shape Engineering /7./ International Conference on Photonic Technologies. Fürth, 12.11.2012-15.12.2012] Institutional support: RVO:68081731 Keywords : laser weld ing * feedback control * frequency analysis * adaptive beam shaping Subject RIV: BH - Optics, Masers, Lasers

  18. Improved laser-based triangulation sensor with enhanced range and resolution through adaptive optics-based active beam control.

    Science.gov (United States)

    Reza, Syed Azer; Khwaja, Tariq Shamim; Mazhar, Mohsin Ali; Niazi, Haris Khan; Nawab, Rahma

    2017-07-20

    Various existing target ranging techniques are limited in terms of the dynamic range of operation and measurement resolution. These limitations arise as a result of a particular measurement methodology, the finite processing capability of the hardware components deployed within the sensor module, and the medium through which the target is viewed. Generally, improving the sensor range adversely affects its resolution and vice versa. Often, a distance sensor is designed for an optimal range/resolution setting depending on its intended application. Optical triangulation is broadly classified as a spatial-signal-processing-based ranging technique and measures target distance from the location of the reflected spot on a position sensitive detector (PSD). In most triangulation sensors that use lasers as a light source, beam divergence-which severely affects sensor measurement range-is often ignored in calculations. In this paper, we first discuss in detail the limitations to ranging imposed by beam divergence, which, in effect, sets the sensor dynamic range. Next, we show how the resolution of laser-based triangulation sensors is limited by the interpixel pitch of a finite-sized PSD. In this paper, through the use of tunable focus lenses (TFLs), we propose a novel design of a triangulation-based optical rangefinder that improves both the sensor resolution and its dynamic range through adaptive electronic control of beam propagation parameters. We present the theory and operation of the proposed sensor and clearly demonstrate a range and resolution improvement with the use of TFLs. Experimental results in support of our claims are shown to be in strong agreement with theory.

  19. Controlling Second Harmonic Efficiency of Laser Beam Interactions

    Science.gov (United States)

    Barnes, Norman P. (Inventor); Walsh, Brian M. (Inventor); Reichle, Donald J. (Inventor)

    2011-01-01

    A method is provided for controlling second harmonic efficiency of laser beam interactions. A laser system generates two laser beams (e.g., a laser beam with two polarizations) for incidence on a nonlinear crystal having a preferred direction of propagation. Prior to incidence on the crystal, the beams are optically processed based on the crystal's beam separation characteristics to thereby control a position in the crystal along the preferred direction of propagation at which the beams interact.

  20. Toward automated beam optics control

    International Nuclear Information System (INIS)

    Silbar, R.R.; Schultz, D.E.

    1987-01-01

    We have begun a program aiming toward automatic control of charged-particle beam optics using artificial intelligence programming techniques. In developing our prototype, we are working with LISP machines and the KEE expert system shell. Our first goal was to develop a ''mouseable'' representation of a typical beam line. This responds actively to changes entered from the mouse or keyboard, giving an updated display of the beam line itself, its optical properties, and the instrumentation and control devices as seen by the operater. We have incorporated TRANSPORT, written in Fortran but running as a callable procedure in the LISP environment, for simulation of the beam-line optics. This paper describes the experience gained in meeting our first goal and discusses plans to extend the work so that it is usable, in realtime, on an operating beam line. 11 refs

  1. Model-based beam control for illumination of remote objects, part II: laboratory testbed

    Science.gov (United States)

    Basu, Santasri; Voelz, David; Chandler, Susan M.; Lukesh, Gordon W.; Sjogren, Jon

    2004-10-01

    When a laser beam propagates through the atmosphere, it is subject to corrupting influences including mechanical vibrations, turbulence and tracker limitations. As a result, pointing errors can occur, causing loss of energy or signal at the target. Nukove Scientific Consulting has developed algorithms to estimate these pointing errors from the statistics of the return photons from the target. To prove the feasibility of this approach for real-time estimation, an analysis tool called RHINO was developed by Nukove. Associated with this effort, New Mexico State University developed a laboratory testbed, the ultimate objective being to test the estimation algorithms under controlled conditions and to stream data into RHINO to prove the feasibility of real-time operation. The present paper outlines the description of this testbed and the results obtained through RHINO when the testbed was used to test the estimation approach.

  2. Multi-Agent Based Beam Search for Real-Time Production Scheduling and Control Method, Software and Industrial Application

    CERN Document Server

    Kang, Shu Gang

    2013-01-01

    The Multi-Agent Based Beam Search (MABBS) method systematically integrates four major requirements of manufacturing production - representation capability, solution quality, computation efficiency, and implementation difficulty - within a unified framework to deal with the many challenges of complex real-world production planning and scheduling problems. Multi-agent Based Beam Search for Real-time Production Scheduling and Control introduces this method, together with its software implementation and industrial applications.  This book connects academic research with industrial practice, and develops a practical solution to production planning and scheduling problems. To simplify implementation, a reusable software platform is developed to build the MABBS method into a generic computation engine.  This engine is integrated with a script language, called the Embedded Extensible Application Script Language (EXASL), to provide a flexible and straightforward approach to representing complex real-world problems. ...

  3. The EPICS-based remote control system for muon beam line devices at J-PARC MUSE

    Energy Technology Data Exchange (ETDEWEB)

    Ito, T U; Higemoto, W [Advanced Science Research Center, Japan Atomic Energy Agency, Tokai, Ibaraki 319-1195 (Japan); Nakahara, K; Fujimori, H; Kobayashi, Y; Miyake, Y [Muon Science Laboratory, High Energy Accelerator Research Organization (KEK), Tsukuba, Ibaraki 305-0801 (Japan); Kawase, M, E-mail: ito.takashi15@jaea.go.j [J-PARC Center, Japan Atomic Energy Agency, Tokai, Ibaraki 319-1195 (Japan)

    2010-04-01

    The remote control system for muon beam line devices of J-PARC MUSE has been developed with the Experimental Physics and Industrial Control System (EPICS). The EPICS input/output controller was installed in standard Linux PCs for slow control of the devices. Power supplies for 21 magnetic elements and four slit controllers for the decay-surface muon beam line in the Materials and Life Science Experimental Facility are now accessible via Ethernet from a graphical user interface which has been composed using the Motif Editor and Display Manger.

  4. MPS beam control software architecture

    International Nuclear Information System (INIS)

    Krauter, K.; Crane, M.

    1993-04-01

    The new Machine Protection System (MPS) now being tested at SLAC has a beam control subsystem resident in processors located close to the beam monitoring devices within the machine. There are two types of beam control micros: Algorithm Processors (AP's) which collect and evaluate data from monitoring devices, and a Supervisor (SUPE) which collects and evaluates data from all the AP's. The SUPE also receives the global machine beamcode indicating beam presence, and passes it on to the AP's. The SUPE receives the beamcode pattern from the Master Pattern Generator (MPG) via a shared-memory communication link. MIL-1553 serial communication is used between the SUPE and the AP's, and between the AP's and the monitoring devices. Multitasking software is used to allow high priority handling of data evaluation and low priority handling of host/user interfacing and event reporting. Pipelining of data between acquisition and evaluation and reporting is used to accomodate the processing capacity, while still supporting full processing at the 360Hz broadcast rate of the beamcode pattern

  5. Beam based alignment at LEP

    CERN Document Server

    Dehning, Bernd; Mugnai, G; Reichel, I; Schmidt, R; Sonnemann, F; Tecker, F A

    2004-01-01

    We describe a beam-based method for finding the relative offset between beam position monitors (BPMs) and the magnetic centres of the adjacent quadrupole magnets. The strength of a given quadrupole is modulated and the induced closed orbit oscillation measured for different beam positions, reaching a minimum when the beam is centred in the quadrupole. The BPM reading at this point is a measure of its offset, which may be determined at LEP with an accuracy of ~40x10-6 m.

  6. LHC beam stability and feedback control

    Energy Technology Data Exchange (ETDEWEB)

    Steinhagen, Ralph

    2007-07-20

    This report presents the stability and the control of the Large Hadron Collider's (LHC) two beam orbits and their particle momenta using beam-based feedback systems. The aim of this report is to contribute to a safe and reliable LHC commissioning and machine operation. The first part of the analysis gives an estimate of the expected sources of orbit and energy perturbations that can be grouped into environmental sources, machine-inherent sources and machine element failures: the slowest perturbation due to ground motion, tides, temperature fluctuations of the tunnel and other environmental influences are described in this report by a propagation model that is both qualitatively and quantitatively supported by geophone and beam motion measurements at LEP and other CERN accelerators. The second part of this analysis deals with the control of the two LHC beams' orbit and energy through automated feedback systems. Based on the reading of the more than 1056 beam position monitors (BPMs) that are distributed over the machine, a central global feedback controller calculates new deflection strengths for the more than 1060 orbit corrector magnets (CODs) that are suitable to correct the orbit and momentum around their references. this report provides an analysis of the BPMs and CODs involved in the orbit and energy feedback. The BPMs are based on a wide-band time normaliser circuit that converts the transverse beam position reading of each individual particle bunch into two laser pulses that are separated by a time delay and transmitted through optical fibres to an acquisition card that converts the delay signals into a digital position. A simple error model has been tested and compared to the measurement accuracy of LHC type BPMs, obtained through beam-based measurements in the SPS. The average beam position is controlled through 1060 superconducting and individually powered corrector dipole magnets. The proposed correction in 'time-domain' consists of a

  7. Controlling field-effect mobility in pentacene-based transistors by supersonic molecular-beam deposition

    International Nuclear Information System (INIS)

    Toccoli, T.; Pallaoro, A.; Coppede, N.; Iannotta, S.; De Angelis, F.; Mariucci, L.; Fortunato, G.

    2006-01-01

    We show that pentacene field-effect transistors, fabricated by supersonic molecular beams, have a performance strongly depending on the precursor's kinetic energy (K E ). The major role played by K E is in achieving highly ordered and flat films. In the range K E ≅3.5-6.5 eV, the organic field effect transistor linear mobility increases of a factor ∼5. The highest value (1.0 cm 2 V -1 s -1 ) corresponds to very uniform and flat films (layer-by-layer type growth). The temperature dependence of mobility for films grown at K E >6 eV recalls that of single crystals (bandlike) and shows an opposite trend for films grown at K E ≤5.5 eV

  8. Beam screen cryogenic control improvements for the LHC run 2

    CERN Document Server

    AUTHOR|(CDS)2068353; Rogez, Edouard; Blanco Vinuela, Enrique; Ferlin, Gerard; Tovar-Gonzalez, Antonio

    2016-01-01

    This paper presents the improvements made on the cryogenic control system for the LHC beam screens. The regulation objective is to maintain an acceptable temperature range around 20 K which simultaneously ensures a good LHC beam vacuum and limits cryogenic heat loads. In total, through the 27 km of the LHC machine, there are 485 regulation loops affected by beam disturbances. Due to the increase of the LHC performance during Run 2, standard PID controllers cannot keeps the temperature transients of the beam screens within desired limits. Several alternative control techniques have been studied and validated using dynamic simulation and then deployed on the LHC cryogenic control system in 2015. The main contribution is the addition of a feed-forward control in order to compensate the beam effects on the beam screen temperature based on the main beam parameters of the machine in real time.

  9. Beam screen cryogenic control improvements for the LHC run 2

    Science.gov (United States)

    Bradu, B.; Rogez, E.; Blanco-Viñuela, E.; Ferlin, G.; Tovar-Gonzalez, A.

    2017-02-01

    This paper presents the improvements made on the cryogenic control system for the LHC beam screens. The regulation objective is to maintain an acceptable temperature range around 20 K which simultaneously ensures a good LHC beam vacuum and limits cryogenic heat loads. In total, through the 27 km of the LHC machine, there are 485 regulation loops affected by beam disturbances. Due to the increase of the LHC performance during Run 2, standard PID controllers cannot keeps the temperature transients of the beam screens within desired limits. Several alternative control techniques have been studied and validated using dynamic simulation and then deployed on the LHC cryogenic control system in 2015. The main contribution is the addition of a feed-forward control in order to compensate the beam effects on the beam screen temperature based on the main beam parameters of the machine in real time.

  10. Proton beam therapy control system

    Science.gov (United States)

    Baumann, Michael A [Riverside, CA; Beloussov, Alexandre V [Bernardino, CA; Bakir, Julide [Alta Loma, CA; Armon, Deganit [Redlands, CA; Olsen, Howard B [Colton, CA; Salem, Dana [Riverside, CA

    2008-07-08

    A tiered communications architecture for managing network traffic in a distributed system. Communication between client or control computers and a plurality of hardware devices is administered by agent and monitor devices whose activities are coordinated to reduce the number of open channels or sockets. The communications architecture also improves the transparency and scalability of the distributed system by reducing network mapping dependence. The architecture is desirably implemented in a proton beam therapy system to provide flexible security policies which improve patent safety and facilitate system maintenance and development.

  11. Beam-Based Procedures for RF Guns

    CERN Document Server

    Krasilnikov, Mikhail; Grabosch, H J; Hartrott, Michael; Hui Han, Jang; Miltchev, Velizar; Oppelt, Anne; Petrosyan, Bagrat; Staykov, Lazar; Stephan, Frank

    2005-01-01

    A wide range of rf photo injector parameters has to be optimized in order to achieve an electron source performance as required for linac based high gain FELs. Some of the machine parameters can not be precisely controlled by direct measurements, whereas the tolerance on them is extremely tight. Therefore, this should be met with beam-based techniques. Procedures for beam-based alignment (BBA) of the laser on the photo cathode as well as solenoid alignment have been developed. They were applied at the Photo Injector Test facility at DESY Zeuthen (PITZ) and at the photo injector of the VUV-FEL at DESY Hamburg. A field balance of the accelerating mode in the 1 ½ cell gun cavity is one of the key beam dynamics issues of the rf gun. Since no direct field measurement in the half and full cell of the cavity is available for the PITZ gun, a beam-based technique to determine the field balance has been proposed. A beam-based rf phase monitoring procedure has been developed as well.

  12. Phase measurement and control of bunched beams

    International Nuclear Information System (INIS)

    Lewis, R.N.

    1978-01-01

    An ion bean buncher was developed at ANL for bunching all ion species through a tandem accelerator. Transit time variations through the tandem, caused by ripple and fluctuations in the injection and lens power supplies and terminal voltage, and to varying voltage distributions in the accelerating tube, cause a beam-phase variation at the output of the tandem. A beam-phase measurement and control system was designed and installed in conjunction with the ion beam buncher to control beam phase at the tandem output. That system is described

  13. A compact control system to achieve stable voltage and low jitter trigger for repetitive intense electron-beam accelerator based on resonant charging

    Directory of Open Access Journals (Sweden)

    Yongfeng Qiu

    2017-08-01

    Full Text Available A compact control system based on Delphi and Field Programmable Gate Array(FPGA is developed for a repetitive intense electron-beam accelerator(IEBA, whose output power is 10GW and pulse duration is 160ns. The system uses both hardware and software solutions. It comprises a host computer, a communication module and a main control unit. A device independent applications programming interface, devised using Delphi, is installed on the host computer. Stability theory of voltage in repetitive mode is analyzed and a detailed overview of the hardware and software configuration is presented. High voltage experiment showed that the control system fulfilled the requests of remote operation and data-acquisition. The control system based on a time-sequence control method is used to keep constant of the voltage of the primary capacitor in every shot, which ensured the stable and reliable operation of the electron beam accelerator in the repetitive mode during the experiment. Compared with the former control system based on Labview and PIC micro-controller developed in our laboratory, the present one is more compact, and with higher precision in the time dimension. It is particularly useful for automatic control of IEBA in the high power microwave effects research experiments where pulse-to-pulse reproducibility is required.

  14. Beam extraction control systems of the fast-cycling synchrotron

    International Nuclear Information System (INIS)

    Toumanian, A.; Zapolski, N.; Nickogosian, V.; Ananian, A.; Kazarian, A.; Khoetsian, M.; Agababian, A.; Matevosian, A.

    1992-01-01

    A compact system controlling the extraction of different beams (gamma, electron, synchrotron radiation) in single and simultaneous operation modes at high electromagnetic disturbances level based on using one computer of IBM PC/AT type is described. (author)

  15. Automated beam steering using optimal control

    Energy Technology Data Exchange (ETDEWEB)

    Allen, C. K. (Christopher K.)

    2004-01-01

    We present a steering algorithm which, with the aid of a model, allows the user to specify beam behavior throughout a beamline, rather than just at specified beam position monitor (BPM) locations. The model is used primarily to compute the values of the beam phase vectors from BPM measurements, and to define cost functions that describe the steering objectives. The steering problem is formulated as constrained optimization problem; however, by applying optimal control theory we can reduce it to an unconstrained optimization whose dimension is the number of control signals.

  16. Rf beam control for the AGS Booster

    Energy Technology Data Exchange (ETDEWEB)

    Brennan, J.M.

    1994-09-26

    RF beam control systems for hadron synchrotrons have evolved over the past three decades into an essentially standard design. The key difference between hadron and lepton machines is the absence of radiation damping and existence of significant frequency variation in the case of hadrons. Although the motion of the hadron in the potential well of the rf wave is inherently stable it is not strongly damped. Damping must be provided by electronic feedback through the accelerating system. This feedback is typically called the phase loop. The technology of the rf beam control system for the AGS Booster synchrotron is described. First, the overall philosophy of the design is explained in terms of a conventional servo system that regulates the beam horizontal position in the vacuum chamber. The concept of beam transfer functions is fundamental to the mathematics of the design process and is reviewed. The beam transfer functions required for this design are derived from first principles. An overview of the beam signal pick-ups and high level rf equipment is given. The major subsystems, the frequency program, the heterodyne system, and beam feedback loops, are described in detail. Beyond accelerating the beam, the rf system must also synchronize the bunches in the Booster to the buckets in the AGS before transfer. The technical challenge in this process is heightened by the need to accomplish synchronization while the frequency is still changing. Details of the synchronization system are given. This report is intended to serve two purposes. One is to document the hardware and performance of the systems that have been built. The other is to serve as a tutorial vehicle from which the non-expert can not only learn the details of this system but also learn the principles of beam control that have led to the particular design choices made.

  17. Rf beam control for the AGS Booster

    International Nuclear Information System (INIS)

    Brennan, J.M.

    1994-01-01

    RF beam control systems for hadron synchrotrons have evolved over the past three decades into an essentially standard design. The key difference between hadron and lepton machines is the absence of radiation damping and existence of significant frequency variation in the case of hadrons. Although the motion of the hadron in the potential well of the rf wave is inherently stable it is not strongly damped. Damping must be provided by electronic feedback through the accelerating system. This feedback is typically called the phase loop. The technology of the rf beam control system for the AGS Booster synchrotron is described. First, the overall philosophy of the design is explained in terms of a conventional servo system that regulates the beam horizontal position in the vacuum chamber. The concept of beam transfer functions is fundamental to the mathematics of the design process and is reviewed. The beam transfer functions required for this design are derived from first principles. An overview of the beam signal pick-ups and high level rf equipment is given. The major subsystems, the frequency program, the heterodyne system, and beam feedback loops, are described in detail. Beyond accelerating the beam, the rf system must also synchronize the bunches in the Booster to the buckets in the AGS before transfer. The technical challenge in this process is heightened by the need to accomplish synchronization while the frequency is still changing. Details of the synchronization system are given. This report is intended to serve two purposes. One is to document the hardware and performance of the systems that have been built. The other is to serve as a tutorial vehicle from which the non-expert can not only learn the details of this system but also learn the principles of beam control that have led to the particular design choices made

  18. Beam based feedback for the Linac coherent light source

    International Nuclear Information System (INIS)

    Fairley, D.; Kim, K.; Luchini, K; Natampalli, P.; Piccoli, L.; Rogind, D.; Straumann, T.

    2012-01-01

    Beam-based feedback control loops are required by the Linac Coherent Light Source (LCLS) program in order to provide fast, single-pulse stabilization of beam parameters. Eight transverse feedback loops, a 6*6 longitudinal feedback loop, and a loop to maintain the electron bunch charge have been commissioned on the LCLS, and have been maintaining stability of the LCLS electron beam at beam rates up to 120 Hz. This paper will discuss the design, configuration and commissioning of the beam-based Fast Feedback System for LCLS. Topics include algorithms for 120 Hz feedback, multi-cast network performance, actuator and sensor performance for single-pulse control and sensor read back, and feedback configuration and run-time control. (authors)

  19. SU-F-T-221: An Assessment of the Potential for Improved Local Control of Skull- Base Chordomas Via Reduction of the Proton Beam Range Uncertainty

    Energy Technology Data Exchange (ETDEWEB)

    Muller, L; Soldner, A; Kirk, M; Fager, M; Solberg, T; Robert, L; Dolney, D [University of Pennsylvania, Philadelphia, PA (United States)

    2016-06-15

    Purpose: The beam range uncertainty presents a special challenge for proton therapy. Novel technologies currently under development offer strategies to reduce the range uncertainty [1,2]. This work quantifies the potential advantages that could be realized by such a reduction for dosimetrically challenging chordomas at the base of skull. Therapeutic improvement was assessed by evaluating tumor control probabilities (TCP) and normal tissue complication probabilities (NTCP). Methods: Treatment plans were made for a modulated-scanned proton delivery technique using the Eclipse treatment planning system. The prescription dose was 7920 cGy to the CTV. Three different range uncertainty scenarios were considered: 5 mm (3.5% of the beam range + 1 mm, representing current clinical practice, “Curr”), 2 mm (1.3%), and 1 mm (0.7%). For each of 4 patients, 3 different PTVs were defined via uniform expansion of the CTV by the value of the range uncertainty. Tumor control probability (TCP) and normal tissue complication probabilities (NTCPs) for organs-at-risk (OARs) were calculated using the Lyman-Kutcher-Burman[3] formalism and published model parameters [ref Terahara[4], quantec S10, Burman Red Journal v21 pp 123]. Our plan optimization strategy was to achieve PTV close to prescription while maintaining OAR NTCP values at or better than the Curr plan. Results: The average TCP values for the 5, 2, and 1 mm range uncertainty scenarios are 51%, 55% and 65%. The improvement in TCP for patients was between 4 and 30%, depending primarily on the proximity of the GTV to OAR. The average NTCPs for the brainstem and cord were about 4% and 1%, respectively, for all target margins. Conclusion: For base of skull chordomas, reduced target margins can substantially increase the TCP without increasing the NTCP. This work demonstrates the potential significance of a reduction in the range uncertainty for proton beams.

  20. The SPL-based Neutrino Super Beam

    CERN Document Server

    Baussan, E; Bobeth, C; Bouquerel, E; Caretta, O; Cupial, P; Davenne, T; Densham, C; Dracos, M; Fitton, M; Gaudiot, G; Kozien, M; Lacny, L; Lepers, B; Longhin, A; Loveridge, P; Osswald, F; Poussot, P; Rooney, M; Skoczen, B; Szybinski, B; Ustrzycka, A; Vassilopoulos, N; Wilcox, D; Wroblewski, A; Wurtz, J; Zeter, V; Zito, M

    2012-01-01

    The EUROnu Super Beam work package has studied a neutrino beam based on SPL at CERN and aimed at MEMPHYS, a large water Cherenkov detector, proposed for the Laboratoire Souterrain de Modane (Fr\\'ejus tunnel, France), with a baseline of 130 km. The aim of this proposed experiment is to study the CP violation in the neutrino sector. In the study reported here, we have developed the conceptual design of the neutrino beam, especially the target and the magnetic focusing device. Indeed, this beam present several unprecedented challenges, like the high primary proton beam power (4 MW), the high repetition rate (50 Hz) and the low energy of the protons (4.5 GeV). The design is completed by a study of all the main component of the system, starting from the transport system to guide the beam to the target up to the beam dump.

  1. Maritime Adaptive Optics Beam Control

    Science.gov (United States)

    2010-09-01

    Griot Helium Neon Class II laser with output power of 0.5 mW, operating at a wavelength of 633 nm. The science camera is an IDS uEye-2210SE CCD camera...produced by Edmund Optics, Newport/New Focus, Thor Labs, and CVI Melles Griot . Two computer controllers are used for the full experimental system. The

  2. Beam based measurement of beam position monitor electrode gains

    Directory of Open Access Journals (Sweden)

    D. L. Rubin

    2010-09-01

    Full Text Available Low emittance tuning at the Cornell Electron Storage Ring (CESR test accelerator depends on precision measurement of vertical dispersion and transverse coupling. The CESR beam position monitors (BPMs consist of four button electrodes, instrumented with electronics that allow acquisition of turn-by-turn data. The response to the beam will vary among the four electrodes due to differences in electronic gain and/or misalignment. This variation in the response of the BPM electrodes will couple real horizontal offset to apparent vertical position, and introduce spurious measurements of coupling and vertical dispersion. To alleviate this systematic effect, a beam based technique to measure the relative response of the four electrodes has been developed. With typical CESR parameters, simulations show that turn-by-turn BPM data can be used to determine electrode gains to within ∼0.1%.

  3. Beam current controller for laser ion source

    Science.gov (United States)

    Okamura, Masahiro

    2014-10-28

    The present invention relates to the design and use of an ion source with a rapid beam current controller for experimental and medicinal purposes. More particularly, the present invention relates to the design and use of a laser ion source with a magnetic field applied to confine a plasma flux caused by laser ablation.

  4. Electric field control of a Bragg diffraction optical beam splitter based on a cubic K(0.99)Li(0.01)Ta(0.63)Nb(0.37)O3 single crystal.

    Science.gov (United States)

    Gong, Dewei; Tian, Hao; Tan, Liying; Zhou, Zhongxiang

    2011-01-01

    We have realized an electric field controlled Bragg diffraction optical beam splitter based on a photorefractive Bragg diffraction grating. In our experiments, the splitter was produced by wave coupling (532.0 nm) with a potassium lithium tantalate niobate single crystal. In the process of splitting, the incident beam could be split into multioutput beams by the splitter. The influence of an externally applied electric field was studied, and the results show that the intensity of the Bragg diffraction could be controlled by the electric field. The polarization properties of the splitter are discussed.

  5. Tumour control in ion beam radiotherapy with different ions in the presence of hypoxia: an oxygen enhancement ratio model based on the microdosimetric kinetic model

    Science.gov (United States)

    Strigari, L.; Torriani, F.; Manganaro, L.; Inaniwa, T.; Dalmasso, F.; Cirio, R.; Attili, A.

    2018-03-01

    Few attempts have been made to include the oxygen enhancement ratio (OER) in treatment planning for ion beam therapy, and systematic studies to evaluate the impact of hypoxia in treatment with the beam of different ion species are sorely needed. The radiobiological models used to quantify the OER in such studies are mainly based on the dose-averaged LET estimates, and do not explicitly distinguish between the ion species and fractionation schemes. In this study, a new type of OER modelling, based on the microdosimetric kinetic model, taking into account the specificity of the different ions, LET spectra, tissues and fractionation schemes, has been developed. The model has been benchmarked with published in vitro data, HSG, V79 and CHO cells in aerobic and hypoxic conditions, for different ion irradiation. The model has been included in the simulation of treatments for a clinical case (brain tumour) using proton, lithium, helium, carbon and oxygen ion beams. A study of the tumour control probability (TCP) as a function of oxygen partial pressure, dose per fraction and primary ion type has been performed. The modelled OER depends on both the LET and ion type, also showing a decrease for an increased dose per fraction with a slope that depends on the LET and ion type, in good agreement with the experimental data. In the investigated clinical case, a significant increase in TCP has been found upon increasing the ion charge. Higher OER variations as a function of dose per fraction have also been found for low-LET ions (up to 15% varying from 2 to 8 Gy(RBE) for protons). This model could be exploited in the identification of treatment condition optimality in the presence of hypoxia, including fractionation and primary particle selection.

  6. Intelligent mirror monitor and controller for synchrotron radiation beam lines

    International Nuclear Information System (INIS)

    Xu, X.L.; Yang, J.

    1983-01-01

    A microprocessor-based, stand-alone mirror monitor and control system has been developed for synchrotron radiation beam lines. The operational requirements for mirror position and tilt angle, including the parameters for controlling the number of steps, direction, speed and acceleration of the driving motors, may be programmed into EPROMS. The instruction sequence to carry out critical motions will be stored in a program buffer. A manual control knob is also provided to fine tune the mirror position if desired. A synchronization scheme for the height and tilt motions maintains a fixed mirror angle during insertion. Absolute height and tilt angle are displayed. Electronic (or programmable) tilt angle limits are provided to protect against damage from misalignment of high power beams such as focussed wiggler beams. A description of mirror drives with a schematic diagram is presented. Although the controller is made for mirror movers, it can be used in other applications where multiple stepping motors perform complex synchronized motions

  7. Controllable light capsules employing modified Bessel-Gauss beams.

    Science.gov (United States)

    Gong, Lei; Liu, Weiwei; Zhao, Qian; Ren, Yuxuan; Qiu, Xingze; Zhong, Mincheng; Li, Yinmei

    2016-07-08

    We report, in theory and experiment, on a novel class of controlled light capsules with nearly perfect darkness, directly employing intrinsic properties of modified Bessel-Gauss beams. These beams are able to naturally create three-dimensional bottle-shaped region during propagation as long as the parameters are properly chosen. Remarkably, the optical bottle can be controlled to demonstrate various geometries through tuning the beam parameters, thereby leading to an adjustable light capsule. We provide a detailed insight into the theoretical origin and characteristics of the light capsule derived from modified Bessel-Gauss beams. Moreover, a binary digital micromirror device (DMD) based scheme is first employed to shape the bottle beams by precise amplitude and phase manipulation. Further, we demonstrate their ability for optical trapping of core-shell magnetic microparticles, which play a particular role in biomedical research, with holographic optical tweezers. Therefore, our observations provide a new route for generating and controlling bottle beams and will widen the potentials for micromanipulation of absorbing particles, aerosols or even individual atoms.

  8. Use of beam deflection to control an electron beam wire deposition process

    Science.gov (United States)

    Taminger, Karen M. (Inventor); Hofmeister, William H. (Inventor); Hafley, Robert A. (Inventor)

    2013-01-01

    A method for controlling an electron beam process wherein a wire is melted and deposited on a substrate as a molten pool comprises generating the electron beam with a complex raster pattern, and directing the beam onto an outer surface of the wire to thereby control a location of the wire with respect to the molten pool. Directing the beam selectively heats the outer surface of the wire and maintains the position of the wire with respect to the molten pool. An apparatus for controlling an electron beam process includes a beam gun adapted for generating the electron beam, and a controller adapted for providing the electron beam with a complex raster pattern and for directing the electron beam onto an outer surface of the wire to control a location of the wire with respect to the molten pool.

  9. Method and apparatus for laser-controlled proton beam radiology

    Science.gov (United States)

    Johnstone, Carol J.

    1998-01-01

    A proton beam radiology system provides cancer treatment and proton radiography. The system includes an accelerator for producing an H.sup.- beam and a laser source for generating a laser beam. A photodetachment module is located proximate the periphery of the accelerator. The photodetachment module combines the H.sup.- beam and laser beam to produce a neutral beam therefrom within a subsection of the H.sup.- beam. The photodetachment module emits the neutral beam along a trajectory defined by the laser beam. The photodetachment module includes a stripping foil which forms a proton beam from the neutral beam. The proton beam is delivered to a conveyance segment which transports the proton beam to a patient treatment station. The photodetachment module further includes a laser scanner which moves the laser beam along a path transverse to the cross-section of the H.sup.- beam in order to form the neutral beam in subsections of the H.sup.- beam. As the scanning laser moves across the H.sup.- beam, it similarly varies the trajectory of the proton beam emitted from the photodetachment module and in turn varies the target location of the proton beam upon the patient. Intensity modulation of the proton beam can also be achieved by controlling the output of the laser.

  10. Energy spectrum control for modulated proton beams

    International Nuclear Information System (INIS)

    Hsi, Wen C.; Moyers, Michael F.; Nichiporov, Dmitri; Anferov, Vladimir; Wolanski, Mark; Allgower, Chris E.; Farr, Jonathan B.; Mascia, Anthony E.; Schreuder, Andries N.

    2009-01-01

    In proton therapy delivered with range modulated beams, the energy spectrum of protons entering the delivery nozzle can affect the dose uniformity within the target region and the dose gradient around its periphery. For a cyclotron with a fixed extraction energy, a rangeshifter is used to change the energy but this produces increasing energy spreads for decreasing energies. This study investigated the magnitude of the effects of different energy spreads on dose uniformity and distal edge dose gradient and determined the limits for controlling the incident spectrum. A multilayer Faraday cup (MLFC) was calibrated against depth dose curves measured in water for nonmodulated beams with various incident spectra. Depth dose curves were measured in a water phantom and in a multilayer ionization chamber detector for modulated beams using different incident energy spreads. Some nozzle entrance energy spectra can produce unacceptable dose nonuniformities of up to ±21% over the modulated region. For modulated beams and small beam ranges, the width of the distal penumbra can vary by a factor of 2.5. When the energy spread was controlled within the defined limits, the dose nonuniformity was less than ±3%. To facilitate understanding of the results, the data were compared to the measured and Monte Carlo calculated data from a variable extraction energy synchrotron which has a narrow spectrum for all energies. Dose uniformity is only maintained within prescription limits when the energy spread is controlled. At low energies, a large spread can be beneficial for extending the energy range at which a single range modulator device can be used. An MLFC can be used as part of a feedback to provide specified energy spreads for different energies.

  11. Ribbon Ion Beam with Controlled Directionality and Local Reactive Chemistry

    Science.gov (United States)

    Biloiu, Costel; Gilchrist, Glen; Kontos, Alex; Basame, Solomon; Rockwell, Tyler; Campbell, Chris; Daniels, Kevin; Allen, Ernest; Wallace, Jay; Ballou, Jon; Hertel, Richard; Chen, Tsung-Liang; Liang, Shurong; Singh, Vikram

    2016-09-01

    A plasma processing technology designed for etch of 3D semiconductor structures is presented. The technology is characterized by controllable ion directionality and local reactive chemistry and it is based on proprietary Applied Materials - Varian Semiconductor Equipment ribbon ion beam architecture. It uses a combination of inert gas ion beam and injection of reactive chemical species at the Point-of-Use (PoU), i.e., at the wafer surface. The ion source uses an inductively coupled plasma source and a diode-type extraction optics. A beam shaping electrode allows extraction of two symmetrical ribbon-like beamlets. The ion beam has in situ controllable ion angular distribution in both mean angle and angular spread. The beam has a uniform distribution of beam current and angles over a waist exceeding 300 mm, allowing full wafer processing in one pass. Chemical compounds are delivered at PoU through linear shower heads. The reactive chemical compound delivered in this fashion maintains its molecular integrity. This result in protection of the trench side walls from deposition of etch residue and facilitates formation of volatile byproducts. The technology was used successfully for mitigation of Magnetic Tunel Junction etch residue. Other applications were this technology differentiate from present technologies are contact liner etch, Co recess, and 1D hole elongation.

  12. Control of beam halo-chaos using fuzzy logic controller

    International Nuclear Information System (INIS)

    Gao Yuan; Yuan Haiying; Tan Guangxing; Luo Wenguang

    2012-01-01

    Considering the ion beam with initial K-V distribution in the periodic focusing magnetic filed channels (PFCs) as a typical sample, a fuzzy control method for control- ling beam halo-chaos was studied. A fuzzy proportional controller, using output of fuzzy inference as a control factor, was presented for adjusting exterior focusing magnetic field. The stability of controlled system was proved by fuzzy phase plane analysis. The simulation results demonstrate that the chaotic radius of envelope can be controlled to the matched radius via controlling magnetic field. This method was also applied to the multi-particle model. Under the control condition, the beam halos and its regeneration can be eliminated effectively, and that both the compactness and the uniformity of ion beam are improved evidently. Since the exterior magnetic field can be rather easily adjusted by proportional control and the fuzzy logic controller is independent to the mathematical model, this method has adaptive ability and is easily realized in experiment. The research offers a valuable reference for the design of the PFCs in the high- current linear ion accelerators. (authors)

  13. Application of In-line Focused Beam Reflectance Measurement to Brivanib Alaninate Wet Granulation Process to Enable Scale-up and Attribute-based Monitoring and Control Strategies.

    Science.gov (United States)

    Narang, Ajit S; Stevens, Timothy; Macias, Kevin; Paruchuri, Srinivasa; Gao, Zhihui; Badawy, Sherif

    2017-01-01

    Application of in-line real-time process monitoring using a process analytical technology for granule size distribution can enable quality-by-design development of a drug product and enable attribute-based monitoring and control strategies. In this study, an in-line laser focused beam reflectance measurement (FBRM) C35 probe was used to investigate the effect of formulation and process parameters on the granule growth profile over time during the high shear wet granulation of a high drug load formulation of brivanib alaninate. The probe quantitatively captured changes in the granule chord length distribution (CLD) with the progress of granulation and delineated the impact of water concentration used during granulation. The results correlated well with offline particle size distribution measured by nested sieve analyses. An end point indication algorithm was developed that was able to successfully track the process time needed to reach the target CLD. Testing of the brivanib alaninate granulation through 25-fold scale-up of the batch process indicated that the FBRM CLD profile can provide a scale-independent granule attribute-based process fingerprint. These studies highlight the ability of FBRM to quantitate a granule attribute of interest during wet granulation that can be used as an attribute-based scale-up and process monitoring and control parameter. Copyright © 2016 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  14. Beam-based Feedback for the Linac Coherent Light Source

    Energy Technology Data Exchange (ETDEWEB)

    Fairley, D.; Allison, S.; Chevtsov, S.; Chu, P.; Decker, F.J.; Emma, P.; Frisch, J.; Himel, T.; Kim, K.; Krejcik, P.; Loos, H.; Lahey, T.; Natampalli, P.; Peng, S.; Rogind, D.; Shoaee, H.; Straumann, T.; Williams, E.; White, G.; Wu, J.; Zelazney, M.; /SLAC

    2010-02-11

    Beam-based feedback control loops are required by the Linac Coherent Light Source (LCLS) program in order to provide fast, single-pulse stabilization of beam parameters. Eight transverse feedback loops, a 6 x 6 longitudinal feedback loop, and a loop to maintain the electron bunch charge were successfully prototyped in MATLAB for the LCLS, and have been maintaining stability of the LCLS electron beam at beam rates up to 30Hz. In the final commissioning phase of LCLS the beam will be operating at up to 120Hz. In order to run the feedback loops at beam rate, the feedback loops will be implemented in EPICS IOCs with a dedicated ethernet multi-cast network. This paper will discuss the design of the beam-based Fast Feedback System for LCLS. Topics include MATLAB feedback prototyping, algorithm for 120Hz feedback, network design for fast data transport, actuator and sensor design for single-pulse control and sensor readback, and feedback configuration and runtime control.

  15. Exact Controllability and Perturbation Analysis for Elastic Beams

    International Nuclear Information System (INIS)

    Moreles, Miguel Angel

    2004-01-01

    The Rayleigh beam is a perturbation of the Bernoulli-Euler beam. We establish convergence of the solution of the Exact Controllability Problem for the Rayleigh beam to the corresponding solution of the Bernoulli-Euler beam. Convergence is related to a Singular Perturbation Problem. The main tool in solving this perturbation problem is a weak version of a lower bound for hyperbolic polynomials

  16. Active vibration control of a piezoelectric beam using PID controller: Experimental study

    Directory of Open Access Journals (Sweden)

    Najeeb ur Rahman

    Full Text Available Vibration suppression of smart beams using the piezoelectric patch structure is presented in the present work. The smart system consists of a beam as the host structure and piezoceramic patches as the actuation and sensing elements. An experimental set-up has been developed to obtain the active vibration suppression of smart beam. The set-up consists of a smart cantilever beam, the data acquisition system and a LabView based controller. Experiments are performed for different beam specimen. The coupled effcient layerwise (zigzag theory is used for theoretical finite element modeling. The finite element model is free of shear locking. The beam element has two nodes with four mechanical and a variable number of electric degrees of freedom at each node. In the thickness direction, the electric field is approximated as piecewise linear across an arbitrary number of sub-layers in the piezoelectric layers. Cubic Hermite interpolation is used for the deflection, and linear interpolation is used for the axial displacement and the shear rotation. Undamped Natural Frequencies are obtained by solving the Eigen Value problem using Subspace Iteration method for cantilever beam. A state space model characterizing the dynamics of the physical system is developed from experimental results using PID approach for the purpose of control law design. The experimental results obtained by using the active vibration control system have demonstrated the validity and effciency of PID controller. Experiments are conducted to compare the controlling of various cantilever beams of different sizes. It shows that the present actuator and sensor based control method is effective and the LabView control plots for various beams can be used as a benchmark for analytical work. The results are compared with ABAQUS software and 1D Finite element formulation based on zigzag theory.

  17. A PC-PCL-based control system for the high-voltage pulsed-power operation of the Intense Diagnostic Neutral Beam (IDNB) Experiment

    International Nuclear Information System (INIS)

    Gribble, R.

    1993-06-01

    A stand-alone, semiautomated control system for the high-voltage pulsed-power energy sources on the Intense Diagnostic Neutral Beam Experiment at Los Alamos National Laboratory using personal computer (PC) and programmable logic controller (PLC) technology has been developed and implemented. The control system, consisting of a PC with the graphic operator interface, the network connecting the PC to the PLC, the PLC, the PLC I/O modules, fiber-optic interfaces and software, is described

  18. Programmable controller--a versatile tool for neutral beam control

    International Nuclear Information System (INIS)

    Campbell, G.L.; Haskovec, J.S.; Moore, C.D.

    1983-01-01

    In neutral beam systems (NB) for the Doublet III fusion experiment at GA Technologies Inc., programmable controllers (PC) are successfully used both on the local and the central levels of control. The local level of control is concentrated in the control instrumentation station (CI), located near the neutral beam tank and its instrumentation. The CI station contains one PC which performs control functions for vacuum, hydrogen, cooling water, automatic cryopanel defrost and recovery from power failure. The CI PC provides interface functions to other local control devices as well as to the NB control computer and central level of control. On the central level the PC creates the main part of a mode control system (MC). It supports mode control panels which serve as global control interface to NB operator, coordinates the operation of NB power supplies, central timing system, neutral beam and tokamak control computers. After a brief exposition of typical functions the implication of requirements such as expandability, reliability and versatility on hardware configuration and program structure will be explained. Results of analysis and tests of time-critical functions will be presented. Finally some aspects of interfaces to different instruments and devices will be described

  19. Backstepping boundary control: an application to the suppression of flexible beam vibration

    Science.gov (United States)

    Boonkumkrong, Nipon; Asadamongkon, Pichai; Chinvorarat, Sinchai

    2018-01-01

    This paper presents a backstepping boundary control for vibration suppression of flexible beam. The applications are such as industrial robotic arms, space structures, etc. Most slender beams can be modelled using a shear beam. The shear beam is more complex than the conventional Euler-Bernoulli beam in that a shear deformation is additionally taken into account. At present, the application of this method in industry is rather limited, because the application of controllers to the beam is difficult. In this research, we use the shear beam with moving base as a model. The beam is cantilever type. This design method allows us to deal directly with the beam’s partial differential equations (PDEs) without resorting to approximations. An observer is used to estimate the deflections along the beam. Gain kernel of the system is calculated and then used in the control law design. The control setup is anti-collocation, i.e. a sensor is placed at the beam tip and an actuator is placed at the beam moving base. Finite difference equations are used to solve the PDEs and the partial integro-differential equations (PIDEs). Control parameters are varied to see their influences that affect the control performance. The results of the control are presented via computer simulation to verify that the control scheme is effective.

  20. Proton-beam writing channel based on an electrostatic accelerator

    Science.gov (United States)

    Lapin, A. S.; Rebrov, V. A.; Kolin'ko, S. V.; Salivon, V. F.; Ponomarev, A. G.

    2016-09-01

    We have described the structure of the proton-beam writing channel as a continuation of a nuclear scanning microprobe channel. The problem of the accuracy of positioning a probe by constructing a new high-frequency electrostatic scanning system has been solved. Special attention has been paid to designing the probe-forming system and its various configurations have been considered. The probe-forming system that best corresponds to the conditions of the lithographic process has been found based on solving the problem of optimizing proton beam formation. A system for controlling beam scanning using multifunctional module of integrated programmable logic systems has been developed.

  1. EPICS Controlled Collimator for Controlling Beam Sizes in HIPPO

    Energy Technology Data Exchange (ETDEWEB)

    Napolitano, Arthur Soriano [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Vogel, Sven C. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-08-03

    Controlling the beam spot size and shape in a diffraction experiment determines the probed sample volume. The HIPPO - High-Pressure-Preferred Orientation– neutron time-offlight diffractometer is located at the Lujan Neutron Scattering Center in Los Alamos National Laboratories. HIPPO characterizes microstructural parameters, such as phase composition, strains, grain size, or texture, of bulk (cm-sized) samples. In the current setup, the beam spot has a 10 mm diameter. Using a collimator, consisting of two pairs of neutron absorbing boron-nitride slabs, horizontal and vertical dimensions of a rectangular beam spot can be defined. Using the HIPPO robotic sample changer for sample motion, the collimator would enable scanning of e.g. cylindrical samples along the cylinder axis by probing slices of such samples. The project presented here describes implementation of such a collimator, in particular the motion control software. We utilized the EPICS (Experimental Physics Interface and Control System) software interface to integrate the collimator control into the HIPPO instrument control system. Using EPICS, commands are sent to commercial stepper motors that move the beam windows.

  2. An elementary presentation of the PS ''beam control'' system

    International Nuclear Information System (INIS)

    Boussard, D.

    1973-01-01

    The PS synchrotron control system is explained in general terms, covering the topics of frequency control, beam transfer, damping, stability, conservation of longitudinal emittance, and second order problems

  3. Adaptive robust control of longitudinal and transverse electron beam profiles

    Science.gov (United States)

    Rezaeizadeh, Amin; Schilcher, Thomas; Smith, Roy S.

    2016-05-01

    Feedback control of the longitudinal and transverse electron beam profiles are considered to be critical for beam control in accelerators. In the feedback scheme, the longitudinal or transverse beam profile is measured and compared to a desired profile to give an error estimate. The error is then used to act on the appropriate actuators to correct the profile. The role of the transverse feedback is to steer the beam in a particular trajectory, known as the "orbit." The common approach for orbit correction is based on approximately inverting the response matrix, and in the best case, involves regulating or filtering the singular values. In the current contribution, a more systematic and structured way of handling orbit correction is introduced giving robustness against uncertainties in the response matrix. Moreover, the input bounds are treated to avoid violating the limits of the corrector currents. The concept of the robust orbit correction has been successfully tested at the SwissFEL injector test facility. In the SwissFEL machine, a photo-injector laser system extracts electrons from a cathode and a similar robust control method is developed for the longitudinal feedback control of the current profile of the electron bunch. The method manipulates the angles of the crystals in the laser system to produce a desired charge distribution over the electron bunch length. This approach paves the way towards automation of laser pulse stacking.

  4. Beam Trajectory control of the future Compact LInear Collider beam

    CERN Document Server

    Balik, G; Bolzon, B; Brunetti, L; Caron, B; Deleglise, G; Jeremie, A; Le Breton, R; Lottin, J; Pacquet, L

    2011-01-01

    The future Compact LInear Collider (CLIC) currently under design at CERN (European Organization for Nuclear Research) would create high-energy particle collisions between electrons and positrons, and provide a tool for scientists to address many of the most compelling questions about the fundamental nature of matter, energy, space and time. In accelerating structure, it is well-established that vibrations generated by the ground motion constitute the main limiting factors for reaching the luminosity of 10^34 cm-2s-1. Several methods have been proposed to counteract this phenomena and active vibration controls based on the integration of mechatronic systems into the machine structure is probably one of the most promising. This paper studies the strategy of the vibration suppression. Active vibration control methods, such as optimized parameter of a numerical compensator, adaptive algorithm with real time control are investigated and implemented in the simulation layout. The requirement couldn’t be achieved w...

  5. QUADRUPOLE BEAM-BASED ALIGNMENT AT RHIC.

    Energy Technology Data Exchange (ETDEWEB)

    NIEDZIELA, J.; MONTAG, C.; SATOGATA, T.

    2005-05-16

    Successful implementation of a beam-based alignment algorithm, tailored to different types of quadrupoles at RHIC, provides significant benefits to machine operations for heavy ions and polarized protons. This algorithm was used to calibrate beam position monitor centers relative to interaction region quadrupoles to maximize aperture. This approach was also used to determine the optimal orbit through transition jump quadrupoles to minimize orbit changes during the transition jump for heavy ion acceleration. This paper provides background discussion and results from first measurements during the RHIC 2005 run.

  6. New control techniques for extraction of bevalac beams

    International Nuclear Information System (INIS)

    Nyman, M.; Chu, W.; Mehlman, B.; Mirer, W.; Oakley, H.; Renner, T.; Stover, G.; Tekawa, M.

    1985-05-01

    Beams of accelerated heavy ions can now be delivered as one-second-long dc pulses with minimal fluctuations in instantaneous flux. Pulse duration can be held constant to within 1% while keeping a high non-varying extraction efficiency which minimizes pulse-to-pulse position shift in the extracted beam. In addition, differing beam intensities over several orders of magnitude can be delivered. Computer adjustment of all measurement and control devices results in linear operation over three orders of magnitude of beam intensity. Control of beam structure is accomplished by a unique combination of dual slope integrators and phase forward ''predictive'' circuits in the feedback loop

  7. Semiautomatic beam-based LHC collimator alignment

    Directory of Open Access Journals (Sweden)

    Gianluca Valentino

    2012-05-01

    Full Text Available Full beam-based alignment of the LHC collimation system was a time-consuming procedure (up to 28 hours as the collimators were set up manually. A yearly alignment campaign has been sufficient for now, although in the future due to tighter tolerances this may lead to a decrease in the cleaning efficiency if machine parameters such as the beam orbit drift over time. Automating the collimator setup procedure can reduce the beam time for collimator setup and allow for more frequent alignments, therefore reducing the risk of performance degradation. This article describes the design and testing of a semiautomatic algorithm as a first step towards a fully automatic setup procedure. The parameters used to measure the accuracy and performance of the alignment are defined and determined from experimental data. A comparison of these measured parameters at 450 GeV and 3.5 TeV with manual and semiautomatic alignment is provided.

  8. Semiautomatic beam-based LHC collimator alignment

    Science.gov (United States)

    Valentino, Gianluca; Aßmann, Ralph; Bruce, Roderik; Redaelli, Stefano; Rossi, Adriana; Sammut, Nicholas; Wollmann, Daniel

    2012-05-01

    Full beam-based alignment of the LHC collimation system was a time-consuming procedure (up to 28 hours) as the collimators were set up manually. A yearly alignment campaign has been sufficient for now, although in the future due to tighter tolerances this may lead to a decrease in the cleaning efficiency if machine parameters such as the beam orbit drift over time. Automating the collimator setup procedure can reduce the beam time for collimator setup and allow for more frequent alignments, therefore reducing the risk of performance degradation. This article describes the design and testing of a semiautomatic algorithm as a first step towards a fully automatic setup procedure. The parameters used to measure the accuracy and performance of the alignment are defined and determined from experimental data. A comparison of these measured parameters at 450 GeV and 3.5 TeV with manual and semiautomatic alignment is provided.

  9. Semiautomatic beam-based LHC collimator alignment

    CERN Document Server

    Valentino, Gianluca; Bruce, Roderik; Wollmann, Daniel; Sammut, Nicholas; Rossi, Adriana; Redaelli, Stefano

    2012-01-01

    Full beam-based alignment of the LHC collimation system was a time-consuming procedure (up to 28 hours) as the collimators were set up manually. A yearly alignment campaign has been sufficient for now, although in the future due to tighter tolerances this may lead to a decrease in the cleaning efficiency if machine parameters such as the beam orbit drift over time. Automating the collimator setup procedure can reduce the beam time for collimator setup and allow for more frequent alignments, therefore reducing the risk of performance degradation. This article describes the design and testing of a semiautomatic algorithm as a first step towards a fully automatic setup procedure. The parameters used to measure the accuracy and performance of the alignment are defined and determined from experimental data. A comparison of these measured parameters at 450 GeV and 3.5 TeV with manual and semiautomatic alignment is provided.

  10. Experimental studies on active vibration control of a smart composite beam using a PID controller

    International Nuclear Information System (INIS)

    Jovanović, Miroslav M; Lukić, Nebojša S; Ilić, Slobodan S; Simonović, Aleksandar M; Zorić, Nemanja D; Stupar, Slobodan N

    2013-01-01

    This paper presents experimental verification of the active vibration control of a smart cantilever composite beam using a PID controller. In order to prevent negative occurrences in the derivative and integral terms in a PID controller, first-order low-pass filters are implemented in the derivative action and in the feedback of the integral action. The proposed application setup consists of a composite cantilever beam with a fiber-reinforced piezoelectric actuator and strain gage sensors. The beam is modeled using a finite element method based on third-order shear deformation theory. The experiment considers vibration control under periodic excitation and an initial static deflection. A control algorithm was implemented on a PIC32MX440F256H microcontroller. Experimental results corresponding to the proposed PID controller are compared with corresponding results using proportional (P) control, proportional–integral (PI) control and proportional–derivative (PD) control. Experimental results indicate that the proposed PID controller provides 8.93% more damping compared to a PD controller, 14.41% more damping compared to a PI controller and 19.04% more damping compared to a P controller in the case of vibration under periodic excitation. In the case of free vibration control, the proposed PID controller shows better performance (settling time 1.2 s) compared to the PD controller (settling time 1.5 s) and PI controller (settling time 2.5 s). (paper)

  11. Biological effect of penetration controlled irradiation with ion beams

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, Atsushi; Shimizu, Takashi; Kikuchi, Masahiro; Kobayashi, Yasuhiko; Watanabe, Hiroshi [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment; Yamashita, Takao

    1997-03-01

    To investigate the effect of local irradiation with ion beams on biological systems, technique for penetration controlled irradiation has been established. The range in a target was controlled by changing the distance from beam window in the atmosphere, and could be controlled linearly up to about 31 {mu}m in biological material. In addition, the effects of the penetration controlled irradiations with 1.5 MeV/u C and He ions were examined using tobacco pollen. The increased frequency of leaky pollen produced by ion beams suggests that the efficient pollen envelope damages would be induced at the range-end of ion beams. (author)

  12. Laser control of atomic beam motion and applications

    International Nuclear Information System (INIS)

    Balykin, V.I.; Letokhov, V.S.

    1987-01-01

    The authors present the results of an experimental investigation of the control of atomic beam motion by the light pressure of laser radiation. Collimation, focusing and reflection of the atomic beam are considered. Collimation of the atomic beam is achieved by the interaction of laser radiation with atoms, when the light pressure force depends only on the atom's velocity. A similar regime of atomic beam interaction with radiation was performed with transversal irradiation of a beam by the axis-symmetrical field. The axis-symmetrical field was formed by laser radiation reflected from the conical mirror surface of a reflecting axicon. The axis of the atomic beam coincided with that of the axicon. The collimation regime was reached under negative detuning of the laser radiation frequency from the atomic transition frequency by a value equal to several homogeneous widths. With positive detuning by the same value the regime of beam decollimation was observed. The density of atoms on the beam axis was changed by 10 3 times, when the collimation regime was replaced by that of decollimation. Focusing of the atomic beam was achieved by light pressure dependent on the atomic coordinate. Focusing was performed within the field configuration formed by divergent laser Gaussian beams propagating in the direction +- X, +- Y of a Cartesian coordinate system. Waists of the laser beams were an equal distance from the atomic beam axis. With an atomic beam propagating along the z axis, expressions for local distance and a formula for the laser lens were obtained. Focusing of the atomic beam was experimentally accomplished, and the image of the atomic beam was received. In this work they also investigated reflection of the atomic beam by laser radiation. The possibility of creating the optics of a neutral atomic beam is shown

  13. Recent improvements of the RF Beam control for LHC-type beams in the CERN PS

    CERN Document Server

    Damerau, H; Schokker, M

    2010-01-01

    To cope with the large variety of different beams for the LHC, the RF beam control in the CERN PS has evolved continuously to improve its flexibility and reliability. Single-bunch beams, several different multi-bunch beams with 25, 50 or 75 ns bunch spacing at ejection for LHC filling, as well as two lead-ion beam variants are now regularly produced in pulse-to-pulse operation. The multibunch beam control for protons can be easily re-adjusted from 0.25 · 1011 to 1.3 · 1011 particles per ejected bunch. Depending on the number of bunches injected from the PS Booster, the length of the ejected bunch train may vary from 8 to 72 bunches. This paper summarizes recent improvements in the low-level RF systems and gives an outlook on the future consolidation.

  14. Beam based measurement of beam position monitor electrode gains

    OpenAIRE

    D. L. Rubin; M. Billing; R. Meller; M. Palmer; M. Rendina; N. Rider; D. Sagan; J. Shanks; C. Strohman

    2010-01-01

    Low emittance tuning at the Cornell Electron Storage Ring (CESR) test accelerator depends on precision measurement of vertical dispersion and transverse coupling. The CESR beam position monitors (BPMs) consist of four button electrodes, instrumented with electronics that allow acquisition of turn-by-turn data. The response to the beam will vary among the four electrodes due to differences in electronic gain and/or misalignment. This variation in the response of the BPM electrodes will couple ...

  15. Optical Beam Jitter Control for the NPS HEL Beam Control Testbed

    Science.gov (United States)

    2011-11-01

    AZT z and ( ) ELT z are used to compute the FSM command and they have to be stable and causal. It is, however, possible to obtain a stable...functions ˆ ( )AZT z and ˆ ( ) ELT z were obtained as follows: ˆ ( ) 18.4592 ( ) ( )AZ IIR aveT z T z T z  (11) ˆ ( ) 20.7145 ( ) ( )EL IIR aveT...Use of least mean squares filter in control of optical beam jitter”, AIAA Journal of Guidance, Control, and Dynamics, 30(4), 2007. [8] Yoon, H

  16. Minimal requirements for quality controls in radiotherapy with external beams

    International Nuclear Information System (INIS)

    1999-01-01

    Physical dosimetric guidelines have been developed by the Italian National Institute of Health study group on quality assurance in radiotherapy to define protocols for quality controls in external beam radiotherapy. While the document does not determine strict rules or firm recommendations, it suggests minimal requirements for quality controls necessary to guarantee an adequate degree of accuracy in external beam radiotherapy [it

  17. Beam current control system for a high-voltage accelerator

    International Nuclear Information System (INIS)

    Razin, G.I.; Val'tman, D.S.; Timofeev, V.E.

    1979-01-01

    A flowsheet of the beam current control system for commercial accelerators is given. Setting and stabilization of a given beam current value are accomplished by the automatic change of a current of a diode electron gun heater or potential of a qrid of three-electrode gun. Beam current coming to an electron-optical converter generates a control signal supplying electron gun. The system operates in the beam current stabilization regime as well as in the radiation dose stabilization regime. The system response amounts to [ru

  18. Beam diagnostics and control for SLC

    International Nuclear Information System (INIS)

    Ross, M.C.

    1987-02-01

    Construction of the SLAC Linear Collider has posed some new problems in beam diagnostic device design. Typical beam sizes are small when compared with conventional storage rings, orbit tolerances are tighter and the pulsed nature of the machine means that signal to noise enhancement by averaging is not always possible. Thus the diagnostics must have high resolution, high absolute accuracy and must deliver data from a single pulse. In practice the required performance level depends on the function and dynamics of a given region in the collider. This paper reviews the major beam diagnostic systems and then discusses the global data acquisition schemes. Each system is described only in a very cursory fashion

  19. Accelerator Based Neutron Beams for Neutron Capture Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Yanch, Jacquelyn C.

    2003-04-11

    The DOE-funded accelerator BNCT program at the Massachusetts Institute of Technology has resulted in the only operating accelerator-based epithermal neutron beam facility capable of generating significant dose rates in the world. With five separate beamlines and two different epithermal neutron beam assemblies installed, we are currently capable of treating patients with rheumatoid arthritis in less than 15 minutes (knee joints) or 4 minutes (finger joints) or irradiating patients with shallow brain tumors to a healthy tissue dose of 12.6 Gy in 3.6 hours. The accelerator, designed by Newton scientific Incorporated, is located in dedicated laboratory space that MIT renovated specifically for this project. The Laboratory for Accelerator Beam Applications consists of an accelerator room, a control room, a shielded radiation vault, and additional laboratory space nearby. In addition to the design, construction and characterization of the tandem electrostatic accelerator, this program also resulted in other significant accomplishments. Assemblies for generating epithermal neutron beams were designed, constructed and experimentally evaluated using mixed-field dosimetry techniques. Strategies for target construction and target cooling were implemented and tested. We demonstrated that the method of submerged jet impingement using water as the coolant is capable of handling power densities of up to 6 x 10(sup 7) W/m(sup 2) with heat transfer coefficients of 10(sup 6)W/m(sup 2)-K. Experiments with the liquid metal gallium demonstrated its superiority compared with water with little effect on the neutronic properties of the epithermal beam. Monoenergetic proton beams generated using the accelerator were used to evaluate proton RBE as a function of LET and demonstrated a maximum RBE at approximately 30-40 keV/um, a finding consistent with results published by other researchers. We also developed an experimental approach to biological intercomparison of epithermal beams and

  20. Topology Control in Aerial Multi-Beam Directional Networks

    Science.gov (United States)

    2017-04-24

    Topology Control in Aerial Multi-Beam Directional Networks Brian Proulx, Nathaniel M. Jones, Jennifer Madiedo, Greg Kuperman {brian.proulx, njones...significant interference. Topology control (i.e., selecting a subset of neighbors to communicate with) is vital to reduce the interference. Good topology ...underlying challenges to topology control in multi-beam direction networks. Two topology control algorithms are developed: a centralized algorithm

  1. Beam Parameter Measurement and Control at the SNS Target

    CERN Document Server

    Plum, Michael; McManamy, Tom

    2005-01-01

    The spallation neutron production target at the SNS facility is designed for 1.4 MW beam power. Both beam position and profile must be carefully controlled within narrow margins to avoid damage to the target. The position must be within 2 mm of the target center, and 90% of the beam must be within the nominal 70 mm x 200 mm spot size, without exceeding 0.18 A/m2

  2. Acoustic beam control in biomimetic projector via velocity gradient

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Xiaowei; Dong, Erqian; Song, Zhongchang [Key Laboratory of Underwater Acoustic Communication and Marine Information Technology of the Ministry of Education, Xiamen University, Xiamen 361005 (China); Zhang, Yu, E-mail: yuzhang@xmu.edu.cn, E-mail: dzk@psu.edu; Tang, Liguo [Key Laboratory of Underwater Acoustic Communication and Marine Information Technology of the Ministry of Education, Xiamen University, Xiamen 361005 (China); State Key Laboratory of Marine Environmental Science, Xiamen University, Xiamen 361005 (China); Cao, Wenwu, E-mail: yuzhang@xmu.edu.cn, E-mail: dzk@psu.edu [Department of Mathematics and Materials Research Institute, The Pennsylvania State University, University Park, Pennsylvania 16802 (United States); Li, Songhai [Sanya Key Laboratory of Marin Mammal and Marine Bioacoustics, Sanya Institute of Deep-Sea Science and Engineering, Chinese Academy of Science, Sanya 57200 (China); Zhang, Sai [Faculty of Science, Jiangsu University, Zhenjiang 212013 (China)

    2016-07-04

    A biomimetic projector (BioP) based on computerized tomography of pygmy sperm whale's biosonar system has been designed using gradient-index (GRIN) material. The directivity of this BioP device was investigated as function of frequency and the velocity gradient of the GRIN material. A strong beam control over a broad bandwidth at the subwavelength scale has been achieved. Compared with a bare subwavelength source, the main lobe pressure of the BioP is about five times as high and the angular resolution is one order of magnitude better. Our results indicate that this BioP has excellent application potential in miniaturized underwater sonars.

  3. ALCBEAM - Neutral beam formation and propagation code for beam-based plasma diagnostics

    Science.gov (United States)

    Bespamyatnov, I. O.; Rowan, W. L.; Liao, K. T.

    2012-03-01

    ALCBEAM is a new three-dimensional neutral beam formation and propagation code. It was developed to support the beam-based diagnostics installed on the Alcator C-Mod tokamak. The purpose of the code is to provide reliable estimates of the local beam equilibrium parameters: such as beam energy fractions, density profiles and excitation populations. The code effectively unifies the ion beam formation, extraction and neutralization processes with beam attenuation and excitation in plasma and neutral gas and beam stopping by the beam apertures. This paper describes the physical processes interpreted and utilized by the code, along with exploited computational methods. The description is concluded by an example simulation of beam penetration into plasma of Alcator C-Mod. The code is successfully being used in Alcator C-Mod tokamak and expected to be valuable in the support of beam-based diagnostics in most other tokamak environments. Program summaryProgram title: ALCBEAM Catalogue identifier: AEKU_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AEKU_v1_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: Standard CPC licence, http://cpc.cs.qub.ac.uk/licence/licence.html No. of lines in distributed program, including test data, etc.: 66 459 No. of bytes in distributed program, including test data, etc.: 7 841 051 Distribution format: tar.gz Programming language: IDL Computer: Workstation, PC Operating system: Linux RAM: 1 GB Classification: 19.2 Nature of problem: Neutral beams are commonly used to heat and/or diagnose high-temperature magnetically-confined laboratory plasmas. An accurate neutral beam characterization is required for beam-based measurements of plasma properties. Beam parameters such as density distribution, energy composition, and atomic excited populations of the beam atoms need to be known. Solution method: A neutral beam is initially formed as an ion beam which is extracted from

  4. An Electronically Controlled 8-Element Switched Beam Planar Array

    KAUST Repository

    Sharawi, Mohammad S.

    2015-02-24

    An 8-element planar antenna array with electronically controlled switchable-beam pattern is proposed. The planar antenna array consists of patch elements and operates in the 2.45 GHz ISM band. The array is integrated with a digitally controlled feed network that provides the required phases to generate 8 fixed beams covering most of the upper hemisphere of the array. Unlike typical switchable beam antenna arrays, which operate only in one plane, the proposed design is the first to provide full 3D switchable beams with simple control. Only a 3-bit digital word is required for the generation of the 8 different beams. The integrated array is designed on a 3-layer PCB on a Taconic substrate (RF60A). The total dimensions of the fabricated array are 187.1 × 261.3 × 1.3mm3.

  5. Beam-based Feedback Simulations for the NLC Linac

    International Nuclear Information System (INIS)

    Hendrickson, Linda

    2000-01-01

    Extensive beam-based feedback systems are planned as an integral part of the Next Linear Collider (NLC) control system. Wakefield effects are a significant influence on the feedback design, imposing both architectural and algorithmic constraints. Studies are in progress to assure the optimal selection of devices and to refine and confirm the algorithms for the system design. The authors show the results of initial simulations, along with evaluations of system response for various conditions of ground motion and other operational disturbances

  6. Negative ion based neutral beams for plasma heating

    International Nuclear Information System (INIS)

    Prelec, K.

    1978-01-01

    Neutral beam systems based on negative ions have been considered because of a high expected power efficiency. Methods for the production, acceleration and neutralization of negative ions will be reviewed and possibilities for an application in neutral beam lines explored

  7. Self colliding beams ('migma') and controlled fusion

    CERN Document Server

    Maglic, Bogdan C; Mazarakis, M; Miller, R A; Nering, J; Powell, C; Treglio, J

    1975-01-01

    While much of the early work on colliding beams was done in the US, the lead on the development of this technique is now held by Europe. The most spectacular being the only colliding of nuclei in the intersecting storage rings at CERN. The idea of using colliding beams for fusion is nearly as old as is the interest in fusion as a source of power, but the problems of low reaction rate and high Coulomb scattering initially seemed insurmountable. The authors describe recent work done at the Fusion Energy Corporation which attempts to overcome these problems. (9 refs).

  8. The beam-beam limit in asymmetric colliders: Optimization of the B-factory parameter base

    International Nuclear Information System (INIS)

    Tennyson, J.L.

    1990-01-01

    This paper presents a general theory of the beam-beam limit in symmetric and asymmetric lepton ring colliders. It shows how the beam-beam limit in these accelerators affects the maximum attainable luminosity and presents a specific algorithm for parameter base optimization. It is shown that the special problems inherent in asymmetric colliders derive not from the asymmetry, but from the fact that the two beams must be in different rings. Computer simulation experiments are used to demonstrate the various phenomena discussed in the theory

  9. Controlled acceleration of superimposed Bessel beams

    CSIR Research Space (South Africa)

    Dudley, Angela L

    2013-06-01

    Full Text Available In this work we present a mechanism for generating superpositions of non-canonical, higherorder Bessel beams, which are characterized by the anisotropy of the optical vortex on the propagation axis, known as the morphology parameter. We implement a...

  10. A test beam upgrade based on the BEPC-LINAC

    International Nuclear Information System (INIS)

    Li Jiacai; Wu Yuanming; Cui Xiangzong; Zhang Liangsheng; Zhou Baoqing; Liu Zhengquan; Zhang Shaoping; Sun Changchun; Zhang Zhuxiang; Zhang Caidi; Zheng Linsheng; Liu Shixing; Shen Ji; Yin Zejie; Zhang Yongming; Chen Ziyu

    2004-01-01

    A total of three beam lines, E1, E2 and E3 have based on the LINAC of BEPC. The E1 beam is to be used for intense slow-positron facility. The E2 is a primary positron or electron beam with an energy of 1.3-1.5 GeV. The E3 is a secondary electron or pion test beam with a momentum can be adjustable continuously. The position accuracy of a detected particle is 0.2-0.4 mm with an event rate of 3 - 4 Hz. This beam has been successfully used for some detectors beam test. (author)

  11. Development of Microcontroller-Based Ball and Beam Trainer Kit

    Directory of Open Access Journals (Sweden)

    Gunawan Dewantoro

    2015-03-01

    Full Text Available Normal 0 false false false EN-US X-NONE X-NONE A ball and beam trainer kit based on microcontroller was developed for teaching control system course for the sophomore students. This specially-purposed kit consists of a ball located on a beam with a fixed axle at one of its end. At the other end, a servomotor was employed to control the position of the ball by adjusting the rotation angle of the servomotor. Seven predetermined positions were set to 10, 20, 30, 40, 50, 60, and 70 cm relative to the fixed axle of the beam. The Proportional-Integral-Derivative (PID scheme was then used to compensate the error. This kit is equipped with a user interface to configure controller coefficients, select the set points, plot the actual ball position, and display parameter values. The user interface program runs on PC or notebook connected to microcontroller via serial communications. A questionnaire-based assessment about the use of this kit was conducted by 17 students taking the course, giving a rating value of 94.12%.

  12. The simulation of the electron beam spot control

    Directory of Open Access Journals (Sweden)

    Stelian Emilian Oltean

    2011-12-01

    Full Text Available Electron beams have many special properties which make them particularly well suited for use in materials processing, wherever conventional techniques failed or proved to be inefficient. The entire process has a lot of time varying parameters, so using a distributed control system for 3d position of the electron beam spot may improve the quality of the material processing. Matlab environment was used for model implementation and simulations of the control system which contains the focusing and deflecting components. Due the nature of the process and knowing the electron beam equipment we proposed for the simulations scenarios with a 3D virtual surface.

  13. Electron backscattering for process control in electron beam welding

    International Nuclear Information System (INIS)

    Ardenne, T. von; Panzer, S.

    1983-01-01

    A number of solutions to the automation of electron beam welding is presented. On the basis of electron backscattering a complex system of process control has been developed. It allows an enlarged imaging of the material's surface, improved adjustment of the beam focusing and definite focus positioning. Furthermore, both manual and automated positioning of the electron beam before and during the welding process has become possible. Monitoring of the welding process for meeting standard welding requirements can be achieved with the aid of a control quantity derived from the results of electronic evaluation of the high-frequency electron backscattering

  14. Application of diamond based beam loss monitors

    Energy Technology Data Exchange (ETDEWEB)

    Hempel, Maria [Brandenburgische Technische Univ. Cottbus (Germany); DESY, Zeuthen (Germany); CERN, Geneva (Switzerland); Baer, Tobias [CERN, Geneva (Switzerland); Hamburg Univ. (Germany); Castro Carballo, Elena Maria [DESY, Zeuthen (Germany); Lohmann, Wolfgang [Brandenburgische Technische Univ. Cottbus (Germany); DESY, Zeuthen (Germany); Schmidt, Ruediger [CERN, Geneva (Switzerland)

    2013-07-01

    The LHC has an operational stored energy of 130MJ per beam. Only a small percentage of beam losses in the LHC equipment can damage material or lead to magnet quenches. Therefore, it is important to monitor different types of beam losses, e.g. scattering on residual gas particles, UFOs, collisions and injection losses. A detailed understanding of beam loss mechanisms is necessary to reduce them and ensure save operation. Two different beam loss monitors are installed in the LHC tunnel: ionization chambers and diamond sensors. Ionization chambers trigger a beam dump if beam losses exceed a certain threshold. They have a time resolution of 40um (half LHC turn) which is not sufficient to resolve bunch-by-bunch beam losses. Diamond sensors have a nanosecond time resolution and can therefore detect bunch-by-bunch beam losses. This time resolution allows an analysis of various types of beam losses and an understanding of the mechanisms. For the first time beam loss intensities were measured bunch-by-bunch caused by different origins of losses. Beam loss measurements using diamond sensors will be presented. The results are compared to simulations and good qualitative agreement was found. The potential of diamond sensors for LHC and experiment applications are discussed.

  15. ISOL based radioactive nuclear beam facilities

    International Nuclear Information System (INIS)

    Nomura, T.

    1991-07-01

    High-intensity and high-quality unstable nuclear beams can be realized by coupling an isotope separator on-line and a proper post accelerator in various primary beams. Some technical features and problems in the production of such beams are discussed. A brief description is given on 'Exotic Nuclei Arena' in Japanese Hadron Project. (author)

  16. Gaussian beam shooting algorithm based on iterative frame decomposition

    OpenAIRE

    Ghannoum, Ihssan; Letrou, Christine; Beauquet, Gilles

    2010-01-01

    International audience; Adaptive beam re-shooting is proposed as a solution to overcome essential limitations of the Gaussian Beam Shooting technique. The proposed algorithm is based on iterative frame decompositions of beam fields in situations where usual paraxial formulas fail to give accurate enough results, such as interactions with finite obstacle edges. Collimated beam fields are successively re-expanded on narrow and wide window frames, allowing for re-shooting and further propagation...

  17. A control and data acquisition system for use in relativistic neutral hydrogen beam studies

    International Nuclear Information System (INIS)

    Anderson, J.R.; Durocher, J.J.G.; Smith, G.R.; James, D.R.

    1987-01-01

    An experimental facility consisting of both hardware and software has been assembled for use in studies with 10 to 50 MeV H 0 beams. With a CAMAC/MBD hardware base, the system controls an optical monochrometer, monitors the H 0 beam, logs data and does preliminary analysis of the results. The system has been successfully adapted to use in other experiments requiring similar monitor and control functions

  18. Controlling FAMA by the Ptolemy II model of ion beam transport

    Energy Technology Data Exchange (ETDEWEB)

    Balvanovic, R. [Vinca Institute of Nuclear Sciences, P.O. Box 522, Belgrade 11001 (Serbia)], E-mail: broman@vinca.rs; Radenovic, B. [Institute of Physics, Pregrevica 118, Belgrade 11080 (Serbia); Belicev, P.; Neskovic, N. [Vinca Institute of Nuclear Sciences, P.O. Box 522, Belgrade 11001 (Serbia)

    2009-08-11

    FAMA is a facility for modification and analysis of materials with ion beams. Due to the wide range of ion beams and energies used in the facility and its future expansion, the need has arisen for faster tuning of ion beams transport control parameters. With this aim, a new approach to modeling ion-beam transport system was developed, based on the Ptolemy II modeling and design framework. A model in Ptolemy II is a hierarchical aggregation of components called actors, which communicate with other actors using tokens, or pieces of data. Each ion optical element is modeled by a composite actor implementing beam matrix transformation function, while tokens carry beam matrix data. A basic library of models of typical ion optical elements is developed, and a complex model of FAMA ion beam transport system is hierarchically integrated with bottom-up approach. The model is extended to include control functions. The developed model is modular, flexible and extensible. The results obtained by simulation on the model demonstrate easy and efficient tuning of beam line control parameters. Fine tuning of control parameters, due to uncertainties inherent to modeling, still has to be performed on-line.

  19. Dynamic Control of Collapse in a Vortex Airy Beam

    Science.gov (United States)

    Chen, Rui-Pin; Chew, Khian-Hooi; He, Sailing

    2013-01-01

    Here we study systematically the self-focusing dynamics and collapse of vortex Airy optical beams in a Kerr medium. The collapse is suppressed compared to a non-vortex Airy beam in a Kerr medium due to the existence of vortex fields. The locations of collapse depend sensitively on the initial power, vortex order, and modulation parameters. The collapse may occur in a position where the initial field is nearly zero, while no collapse appears in the region where the initial field is mainly distributed. Compared with a non-vortex Airy beam, the collapse of a vortex Airy beam can occur at a position away from the area of the initial field distribution. Our study shows the possibility of controlling and manipulating the collapse, especially the precise position of collapse, by purposely choosing appropriate initial power, vortex order or modulation parameters of a vortex Airy beam. PMID:23518858

  20. Computer controlled vacuum control system for synchrotron radiation beam lines

    International Nuclear Information System (INIS)

    Goldberg, S.M.; Wang, C.; Yang, J.

    1983-01-01

    The increasing number and complexity of vacuum control systems at the Stanford Synchrotron Radiation Laboratory has resulted in the need to computerize its operations in order to lower costs and increase efficiency of operation. Status signals are transmitted through digital and analog serial data links which use microprocessors to monitor vacuum status continuously. Each microprocessor has a unique address and up to 256 can be connected to the host computer over a single RS232 data line. A FORTRAN program on the host computer will request status messages and send control messages via only one RS232 line per beam line, signal the operator when a fault condition occurs, take automatic corrective actions, warn of impending valve failure, and keep a running log of all changes in vacuum status for later recall. Wiring costs are thus greatly reduced and more status conditions can be monitored without adding excessively to the complexity of the system. Operators can then obtain status reports at various locations in the lab quickly without having to read a large number of meter and LED's

  1. [External beam radiotherapy cone beam-computed tomography-based dose calculation].

    Science.gov (United States)

    Barateau, A; Céleste, M; Lafond, C; Henry, O; Couespel, S; Simon, A; Acosta, O; de Crevoisier, R; Périchon, N

    2018-02-01

    In external beam radiotherapy, the dose planning is currently based on computed tomography (CT) images. A relation between Hounsfield numbers and electron densities (or mass densities) is necessary for dose calculation taking heterogeneities into account. In image-guided radiotherapy process, the cone beam CT is classically used for tissue visualization and registration. Cone beam CT for dose calculation is also attractive in dose reporting/monitoring perspectives and particularly in a context of dose-guided adaptive radiotherapy. The accuracy of cone beam CT-based dose calculation is limited by image characteristics such as quality, Hounsfield numbers consistency and restrictive sizes of volume acquisition. The analysis of the literature identifies three kinds of strategies for cone beam CT-based dose calculation: establishment of Hounsfield numbers versus densities curves, density override to regions of interest, and deformable registration between CT and cone beam CT images. Literature results show that discrepancies between the reference CT-based dose calculation and the cone beam CT-based dose calculation are often lower than 3%, regardless of the method. However, they can also reach 10% with unsuitable method. Even if the accuracy of the cone beam CT-based dose calculation is independent of the method, some strategies are promising but need improvements in the automating process for a routine implementation. Copyright © 2017 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.

  2. Digital feed back control for radial beam position

    International Nuclear Information System (INIS)

    Mestha, L.K.

    1989-09-01

    In the development of wide spread large scale distributed digital control systems, there is a requirement to automate small processes like radial beam control which will not only improve the beam quality but will also add local intelligence. Hence use is made here of digital control principles for such applications. The work concerned with the radial beam control discussed in this report has been developed for ISIS at RAL. The structure of the report is hence inclined more towards the local hardware system. The general feed back loop techniques can also be implemented for other control purpose. For instance, the author has successfully tested similar techniques to minimise the RF cavity tuning error, where the improvement in performance could not be matched by the analogue loop. A description of the RF cavity tuning programme and the associated experimental results will be published as a local paper for ISIS division. (author)

  3. Torsion sensing based on patterned piezoelectric beams

    Science.gov (United States)

    Cha, Youngsu; You, Hangil

    2018-03-01

    In this study, we investigated the sensing characteristics of piezoelectric beams under torsional loads. We used partially patterned piezoelectric beams to sense torsion. In particular, the piezoelectric patches are located symmetrically with respect to the line of the shear center of the beam. The patterned piezoelectric beam is modeled as a slender beam, and its electrical responses are obtained by piezoelectric electromechanical equations. To validate the modeling framework, experiments are performed using a setup that forces pure torsional deformation. Three different geometric configurations of the patterned piezoelectric layer are used for the experiments. The frequency and amplitude of the forced torsional load are systematically varied in order to study the behavior of the piezoelectric sensor. Experimental results demonstrate that two voltage outputs of the piezoelectric beam are approximately out of phase with identical amplitude. Moreover, the length of the piezoelectric layers has a significant influence on the sensing properties. Our theoretical predictions using the model support the experimental findings.

  4. ISABELLE accelerator software, control system, and beam diagnostic philosophy

    International Nuclear Information System (INIS)

    Cornacchia, M.; Humphrey, J.W.; Niederer, J.; Poole, J.H.

    1981-01-01

    The ISABELLE Project combines two large proton accelerators with two storage rings in the same facility using superconducting magnet technology. This combination leads to severe constraints on beam loss in magnets and involves complex treatment of magnetic field imperfections and correction elements. The consequent demands placed upon beam diagnostics, accelerator model programs, and the computer oriented control system are discussed in terms of an illustrative operation scenario

  5. Advances in complexity of beam halo-chaos and its control methods for beam transport networks

    International Nuclear Information System (INIS)

    Fang Jinqing

    2004-11-01

    The complexity theory of beam halo-chaos in beam transport networks and its control methods for a new subject of high-tech field is discussed. It is pointed that in recent years, there has been growing interest in proton beams of high power linear accelerator due to its attractive features in possible breakthrough applications in national defense and industry. In particular, high-current accelerator driven clean activity nuclear power systems for various applications as energy resources has been one of the most focusing issues in the current research, because it provides a safer, cleaner and cheaper nuclear energy resource. However, halo-chaos in high-current beam transport networks become a key concerned issue because it can generate excessive radioactivity therefore significantly limits its applications. It is very important to study the complexity properties of beam halo-chaos and to understand the basic physical mechanisms for halo chaos formation as well as to develop effective control methods for its suppression. These are very challenging subjects for the current research. The main research advances in the subjects, including experimental investigation and the oretical research, especially some very efficient control methods developed through many years of efforts of authors are reviewed and summarized. Finally, some research outlooks are given. (author)

  6. Research on automatic correction of electronic beam path for distributed control

    International Nuclear Information System (INIS)

    Guo Xin; Su Haijun; Li Deming; Wang Shengli; Guo Honglei

    2014-01-01

    Background: Dynamitron, an electron irradiation accelerator of high-voltage, is used as a radiation source for industrial and agricultural production. The control system is an important component of dynamitron. Purpose: The aim is to improve the control system to meet the performance requirements of dynamitron for the stability. Methods: A distributed control system for the 1.5-MeV dynamitron is proposed to gain better performance. On this basis, an electron beam trajectory automatic correction method based on Cerebellar Model Articulation Controller and Proportional-Integral Derivative (CMAC-PID) controller is designed to improve the function of electron beam extraction system. Results: The distributed control system can meet the control requirements of the accelerator. The stability of the CMAC PID controller is better than that of conventional PID controller for the electron beam trajectory automatic correction system, and hence the CMAC-PID controller can provide better protection of dynamitron when electron beam deflection occurs. Conclusion: The distributed control system and the electron beam trajectory automatic correction method system can effectively improve the performance and reduce the failure probability of the accelerator, thereby enhancing the efficiency of the accelerator. (authors)

  7. Thermionic gun control system for the CEBAF [Continuous Electron Beam Accelerator Facility] injector

    International Nuclear Information System (INIS)

    Pico, R.; Diamond, B.; Fugitt, J.; Bork, R.

    1989-01-01

    The injector for the CEBAF accelerator must produce a high-quality electron beam to meet the overall accelerator specifications. A Hermosa electron gun with a 2 mm-diameter cathode and a control aperture has been chosen as the electron source. This must be controlled over a wide range of operating conditions to meet the beam specifications and to provide flexibility for accelerator commissioning. The gun is controlled using Computer Automated Measurement and Control (CAMAC IEEE-583) technology. The system employs the CAMAC-based control architecture developed at CEBAF. The control system has been tested, and early operating data on the electron gun and the injector beam transport system has been obtained. This system also allows gun parameters to be stored at the operator location, without paralyzing operation. This paper describes the use of this computer system in the control of the CEBAF electron gun. 2 refs., 6 figs., 1 tab

  8. Vibration attenuation and shape control of surface mounted, embedded smart beam

    Directory of Open Access Journals (Sweden)

    Vivek Rathi

    Full Text Available Active Vibration Control (AVC using smart structure is used to reduce the vibration of a system by automatic modification of the system structural response. AVC is widely used, because of its wide and broad frequency response range, low additional mass, high adaptability and good efficiency. A lot of research has been done on Finite Element (FE models for AVC based on Euler Bernoulli Beam Theory (EBT. In the present work Timoshenko Beam Theory (TBT is used to model a smart cantilever beam with surface mounted sensors / actuators. A Periodic Output Feedback (POF Controller has been designed and applied to control the first three modes of vibration of a flexible smart cantilever beam. The difficulties encountered in the usage of surface mounted piezoelectric patches in practical situations can be overcome by the use of embedded shear sensors / actuators. A mathematical model of a smart cantilever beam with embedded shear sensors and actuators is developed. A POF Controller has been designed and applied to control of vibration of a flexible smart cantilever beam and effect of actuator location on the performance of the controller is investigated. The mathematical modeling and control of a Multiple Input multiple Output (MIMO systems with two sensors and two actuators have also been considered.

  9. A beam monitor based on MPGD detectors for hadron therapy

    Science.gov (United States)

    Altieri, P. R.; Di Benedetto, D.; Galetta, G.; Intonti, R. A.; Mercadante, A.; Nuzzo, S.; Verwilligen, P.

    2018-02-01

    Remarkable scientific and technological progress during the last years has led to the construction of accelerator based facilities dedicated to hadron therapy. This kind of technology requires precise and continuous control of position, intensity and shape of the ions or protons used to irradiate cancers. Patient safety, accelerator operation and dose delivery should be optimized by a real time monitoring of beam intensity and profile during the treatment, by using non-destructive, high spatial resolution detectors. In the framework of AMIDERHA (AMIDERHA - Enhanced Radiotherapy with HAdron) project funded by the Ministero dell'Istruzione, dell'Università e della Ricerca (Italian Ministry of Education and Research) the authors are studying and developing an innovative beam monitor based on Micro Pattern Gaseous Detectors (MPDGs) characterized by a high spatial resolution and rate capability. The Monte Carlo simulation of the beam monitor prototype was carried out to optimize the geometrical set up and to predict the behavior of the detector. A first prototype has been constructed and successfully tested using 55Fe, 90Sr and also an X-ray tube. Preliminary results on both simulations and tests will be presented.

  10. Laser beam shaping design based on micromirror array

    Science.gov (United States)

    Fang, Han; Su, Bida; Liu, Jiaguo; Fan, Xiaoli; Jing, Wang

    2017-10-01

    In the practical application of the laser, it is necessary to use the laser beam shaping technology to shape the output beam of laser device to the uniform light intensity distribution. The shaping divergent optical system of compound eye integrator way is composed of beam expanding mirror group and lens array. Its working principle is to expand the output laser to a certain size of caliber, and then divide the beam with lens array into multiple sub beam, where the lens unit of lens array can control the divergence angle of sub beam through the design of focal length, with mutual superposition of the sub beam in far field, to make up for the nonuniformity of beam, so that the radiant exitance on the radiated surface may become uniform. In this paper, we use a reflective microlens array to realize the laser beam shaping. By through of the practical optical path model established, the ray tracing is carried out and the simulation results for single-mode Gaussian beam with noise circumstance is provided. The analysis results show that the laser beam shaping under different inputs can be effectively realized by use of microlens array. All the energy is within the signal window, with a high energy efficiency of more than 90%; The measured surface has a better uniformity, and the uniformity is better than 99.5% at 150m.

  11. Low power RF beam control electronics for the LEB

    International Nuclear Information System (INIS)

    Mestha, L.K.; Mangino, J.; Brouk, V.; Uher, T.; Webber, R.C.

    1993-05-01

    Beam Control Electronics for the Low Energy Booster (LEB) should provide a fine reference phase and frequency for the High Power RF System. Corrections applied on the frequency of the rf signal will reduce dipole synchrotron oscillations due to power supply regulation errors, errors in frequency source or errors in the cavity voltage. It will allow programmed beam radial position control throughout the LEB acceleration cycle. Furthermore the rf signal provides necessary connections during, adiabatic capture of the beam as injected into the LEB by the Linac and will guarantee LEB rf phase synchronism with the Medium Energy Booster (MEB) rf at a programmed time in the LEB cycle between a unique LEB bucket and a unique MEB bucket. We show in this paper a design and possible interfaces with other subsystems of the LEB such as the beam instrumentation, High Power RF Stations, global accelerator controls and the precision timing system. The outline of various components of the beam control system is also presented followed by some test results

  12. Logic and control module for the Fermilab booster beam damper

    International Nuclear Information System (INIS)

    Sandberg, B.R.

    1977-01-01

    A logic and control module is included in the electronic system of the booster superdamper. This module produces a 9-bit digital word that controls the delay of beam bunch position information in the Fermilab booster synchrotron so that it arrives at the damping electrodes at the same time as the bunch of beam to be corrected. This delay word generator also has an output feature that only allows delay time decreases as the booster synchrotron frequency program increases monotonically. Such a feature guards against low-index incidental FM from affecting the delay computations

  13. Simulations of S-band RF gun with RF beam control

    Science.gov (United States)

    Barnyakov, A. M.; Levichev, A. E.; Maltseva, M. V.; Nikiforov, D. A.

    2017-08-01

    The RF gun with RF control is discussed. It is based on the RF triode and two kinds of the cavities. The first cavity is a coaxial cavity with cathode-grid assembly where beam bunches are formed, the second one is an accelerating cavity. The features of such a gun are the following: bunched and relativistic beams in the output of the injector, absence of the back bombarding electrons, low energy spread and short length of the bunches. The scheme of the injector is shown. The electromagnetic field simulation and longitudinal beam dynamics are presented. The possible using of the injector is discussed.

  14. Resonant vibration control of rotating beams

    DEFF Research Database (Denmark)

    Svendsen, Martin Nymann; Krenk, Steen; Høgsberg, Jan Becker

    2011-01-01

    Rotatingstructures,like e.g.wind turbine blades, may be prone to vibrations associated with particular modes of vibration. It is demonstrated, how this type of vibrations can be reduced by using a collocated sensor–actuator system, governed by a resonant controller. The theory is here demonstrated...... modal connectivity, only very limited modal spill-over is generated. The controller acts by resonance and therefore has only a moderate energy consumption, and successfully reduces modal vibrations at the resonance frequency....

  15. Implementation to spanish protocol of quality control of accelerators to daily control of electron beams

    International Nuclear Information System (INIS)

    Adaimi Hernandez, P.; Ramirez Ros, J. C.; Casa de Julian, M. A. de la; Clemente Gutierrez, F.; Cabello Murillo, E.; Diaz Fuente, R.; Ferrando Sanchez, A.

    2011-01-01

    A revised procedure for daily control of the electron beams to make measurements more meaningful physically, having a better reproducibility and more in line with the recommendations of the Spanish Protocol for Quality Control in Electron Linear Accelerators Clinical Use. The daily quality control beams of high energy electrons that had been done so far was the finding that the record of a series of measures (symmetry, uniformity, stability, energy, beam central dose) were within tolerance values established. The amendment is to check the beam quality by directly measuring changes in absorption depth at which the dose is reduced to half its maximum value, R50.

  16. Applications of power beaming from space-based nuclear power stations. [Laser beaming to airplanes; microwave beaming to ground

    Energy Technology Data Exchange (ETDEWEB)

    Powell, J.R.; Botts, T.E.; Hertzberg, A.

    1981-01-01

    Power beaming from space-based reactor systems is examined using an advanced compact, lightweight Rotating Bed Reactor (RBR). Closed Brayton power conversion efficiencies in the range of 30 to 40% can be achieved with turbines, with reactor exit temperatures on the order of 2000/sup 0/K and a liquid drop radiator to reject heat at temperatures of approx. 500/sup 0/K. Higher RBR coolant temperatures (up to approx. 3000/sup 0/K) are possible, but gains in power conversion efficiency are minimal, due to lower expander efficiency (e.g., a MHD generator). Two power beaming applications are examined - laser beaming to airplanes and microwave beaming to fixed ground receivers. Use of the RBR greatly reduces system weight and cost, as compared to solar power sources. Payback times are a few years at present prices for power and airplane fuel.

  17. Excimer laser beam profile recording based on electrochemical etched polycarbonate

    International Nuclear Information System (INIS)

    Parvin, P.; Jaleh, B.; Zangeneh, H.R.; Zamanipour, Z.; Davoud-Abadi, Gh.R.

    2008-01-01

    There is no polymeric detector used to register the beam profile of UV lasers. Here, a method is proposed for the measurement of intensive UV beam pattern of the excimer lasers based on the photoablated polycarbonate detector after coherent UV exposure and the subsequent electrochemical etching. UV laser induced defects in the form of self-microstructuring on polycarbonate are developed to replicate the spatial intensity distribution as a beam profiler

  18. Nonlinear free vibration control of beams using acceleration delayed-feedback control

    International Nuclear Information System (INIS)

    Alhazza, Khaled A; Alajmi, Mohammed; Masoud, Ziyad N

    2008-01-01

    A single-mode delayed-feedback control strategy is developed to reduce the free vibrations of a flexible beam using a piezoelectric actuator. A nonlinear variational model of the beam based on the von Kàrmàn nonlinear type deformations is considered. Using Galerkin's method, the resulting governing partial differential equations of motion are reduced to a system of nonlinear ordinary differential equations. A linear model using the first mode is derived and is used to characterize the damping produced by the controller as a function of the controller's gain and delay. Three-dimensional figures showing the damping magnitude as a function of the controller gain and delay are presented. The characteristic damping of the controller as predicted by the linear model is compared to that calculated using direct long-time integration of a three-mode nonlinear model. Optimal values of the controller gain and delay using both methods are obtained, simulated and compared. To validate the single-mode approximation, numerical simulations are performed using a three-mode full nonlinear model. Results of the simulations demonstrate an excellent controller performance in mitigating the first-mode vibration

  19. Conceptual design of hollow electron lenses for beam halo control in the Large Hadron Collider

    Energy Technology Data Exchange (ETDEWEB)

    Stancari, Giulio [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Previtali, Valentina [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Valishev, Alexander [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Bruce, Roderik [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Redaelli, Stefano [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Rossi, Adriana [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Salvachua Ferrando, Belen [European Organization for Nuclear Research (CERN), Geneva (Switzerland)

    2014-06-26

    Collimation with hollow electron beams is a technique for halo control in high-power hadron beams. It is based on an electron beam (possibly pulsed or modulated in intensity) guided by strong axial magnetic fields which overlaps with the circulating beam in a short section of the ring. The concept was tested experimentally at the Fermilab Tevatron collider using a hollow electron gun installed in one of the Tevatron electron lenses. We are proposing a conceptual design for applying this technique to the Large Hadron Collider at CERN. A prototype hollow electron gun for the LHC was built and tested. The expected performance of the hollow electron beam collimator was based on Tevatron experiments and on numerical tracking simulations. Halo removal rates and enhancements of halo diffusivity were estimated as a function of beam and lattice parameters. Proton beam core lifetimes and emittance growth rates were checked to ensure that undesired effects were suppressed. Hardware specifications were based on the Tevatron devices and on preliminary engineering integration studies in the LHC machine. Required resources and a possible timeline were also outlined, together with a brief discussion of alternative halo-removal schemes and of other possible uses of electron lenses to improve the performance of the LHC.

  20. Parametric Design and Mechanical Analysis of Beams based on SINOVATION

    Science.gov (United States)

    Xu, Z. G.; Shen, W. D.; Yang, D. Y.; Liu, W. M.

    2017-07-01

    In engineering practice, engineer needs to carry out complicated calculation when the loads on the beam are complex. The processes of analysis and calculation take a lot of time and the results are unreliable. So VS2005 and ADK are used to develop a software for beams design based on the 3D CAD software SINOVATION with C ++ programming language. The software can realize the mechanical analysis and parameterized design of various types of beams and output the report of design in HTML format. Efficiency and reliability of design of beams are improved.

  1. Sound beam manipulation based on temperature gradients

    Energy Technology Data Exchange (ETDEWEB)

    Qian, Feng [Key Laboratory of Modern Acoustics, Institute of Acoustics and School of Physics, Collaborative Innovation Center of Advanced Microstructures, Nanjing University, Nanjing 210093 (China); School of Physics & Electronic Engineering, Changshu Institute of Technology, Changshu 215500 (China); Quan, Li; Liu, Xiaozhou, E-mail: xzliu@nju.edu.cn; Gong, Xiufen [Key Laboratory of Modern Acoustics, Institute of Acoustics and School of Physics, Collaborative Innovation Center of Advanced Microstructures, Nanjing University, Nanjing 210093 (China)

    2015-10-28

    Previous research with temperature gradients has shown the feasibility of controlling airborne sound propagation. Here, we present a temperature gradients based airborne sound manipulation schemes: a cylindrical acoustic omnidirectional absorber (AOA). The proposed AOA has high absorption performance which can almost completely absorb the incident wave. Geometric acoustics is used to obtain the refractive index distributions with different radii, which is then utilized to deduce the desired temperature gradients. Since resonant units are not applied in the scheme, its working bandwidth is expected to be broadband. The scheme is temperature-tuned and easy to realize, which is of potential interest to fields such as noise control or acoustic cloaking.

  2. Sound beam manipulation based on temperature gradients

    International Nuclear Information System (INIS)

    Qian, Feng; Quan, Li; Liu, Xiaozhou; Gong, Xiufen

    2015-01-01

    Previous research with temperature gradients has shown the feasibility of controlling airborne sound propagation. Here, we present a temperature gradients based airborne sound manipulation schemes: a cylindrical acoustic omnidirectional absorber (AOA). The proposed AOA has high absorption performance which can almost completely absorb the incident wave. Geometric acoustics is used to obtain the refractive index distributions with different radii, which is then utilized to deduce the desired temperature gradients. Since resonant units are not applied in the scheme, its working bandwidth is expected to be broadband. The scheme is temperature-tuned and easy to realize, which is of potential interest to fields such as noise control or acoustic cloaking

  3. Actuator Location and Voltages Optimization for Shape Control of Smart Beams Using Genetic Algorithms

    Directory of Open Access Journals (Sweden)

    Georgios E. Stavroulakis

    2013-10-01

    Full Text Available This paper presents a numerical study on optimal voltages and optimal placement of piezoelectric actuators for shape control of beam structures. A finite element model, based on Timoshenko beam theory, is developed to characterize the behavior of the structure and the actuators. This model accounted for the electromechanical coupling in the entire beam structure, due to the fact that the piezoelectric layers are treated as constituent parts of the entire structural system. A hybrid scheme is presented based on great deluge and genetic algorithm. The hybrid algorithm is implemented to calculate the optimal locations and optimal values of voltages, applied to the piezoelectric actuators glued in the structure, which minimize the error between the achieved and the desired shape. Results from numerical simulations demonstrate the capabilities and efficiency of the developed optimization algorithm in both clamped−free and clamped−clamped beam problems are presented.

  4. Multi-layered controllable stiffness beams for morphing: energy, actuation force, and material strain considerations

    International Nuclear Information System (INIS)

    Murray, Gabriel; Gandhi, Farhan

    2010-01-01

    Morphing aerospace structures could benefit from the ability of structural elements to transition from a stiff load-bearing state to a relatively compliant state that can undergo large deformation at low actuation cost. The present paper focuses on multi-layered beams with controllable flexural stiffness—comprising polymer layers affixed to the surfaces of a base beam and cover layers, in turn, affixed to the surfaces of the polymer layers. Heating the polymer through the glass transition reduces its shear modulus, decouples the cover layers from the base beam and reduces the overall flexural stiffness. Although the stiffness and actuation force required to bend the beam reduce, the energy required to heat the polymer layer must also be considered. Results show that for beams with low slenderness ratios, relatively thick polymer layers, and cover layers whose extensional stiffness is high, the decoupling of the cover layers through softening of the polymer layers can result in flexural stiffness reductions of over 95%. The energy savings are also highest for these configurations, and will increase as the deformation of the beam increases. The decoupling of the cover layers from the base beam through the softening of the polymer reduces the axial strains in the cover layers significantly; otherwise material failure would prevent large deformation. Results show that when the polymer layer is stiff, the cover layers are the dominant contributors to the total energy in the beam, and the energy in the polymer layers is predominantly axial strain energy. When the polymer layers are softened the energy in the cover layers is a small contributor to the total energy which is dominated by energy in the base beam and shear strain energy in the polymer layer

  5. A piezoelectric vibration harvester based on clamped-guided beams

    NARCIS (Netherlands)

    Wang, Z.; Matova, S.; Elfrink, R.; Jambunathan, M.; Nooijer, C. de; Schaijk, R. van; Vullers, R.J.M.

    2012-01-01

    The paper addresses the design, modeling, fabrication and experimental results of a piezoelectric energy harvester based on clamped-guided beams. The design is featured by shorter mass displacement and higher reliability than cantilever beams. Two separate sets of capacitors allow exploiting both

  6. Automatic learning-based beam angle selection for thoracic IMRT.

    Science.gov (United States)

    Amit, Guy; Purdie, Thomas G; Levinshtein, Alex; Hope, Andrew J; Lindsay, Patricia; Marshall, Andrea; Jaffray, David A; Pekar, Vladimir

    2015-04-01

    The treatment of thoracic cancer using external beam radiation requires an optimal selection of the radiation beam directions to ensure effective coverage of the target volume and to avoid unnecessary treatment of normal healthy tissues. Intensity modulated radiation therapy (IMRT) planning is a lengthy process, which requires the planner to iterate between choosing beam angles, specifying dose-volume objectives and executing IMRT optimization. In thorax treatment planning, where there are no class solutions for beam placement, beam angle selection is performed manually, based on the planner's clinical experience. The purpose of this work is to propose and study a computationally efficient framework that utilizes machine learning to automatically select treatment beam angles. Such a framework may be helpful for reducing the overall planning workload. The authors introduce an automated beam selection method, based on learning the relationships between beam angles and anatomical features. Using a large set of clinically approved IMRT plans, a random forest regression algorithm is trained to map a multitude of anatomical features into an individual beam score. An optimization scheme is then built to select and adjust the beam angles, considering the learned interbeam dependencies. The validity and quality of the automatically selected beams evaluated using the manually selected beams from the corresponding clinical plans as the ground truth. The analysis included 149 clinically approved thoracic IMRT plans. For a randomly selected test subset of 27 plans, IMRT plans were generated using automatically selected beams and compared to the clinical plans. The comparison of the predicted and the clinical beam angles demonstrated a good average correspondence between the two (angular distance 16.8° ± 10°, correlation 0.75 ± 0.2). The dose distributions of the semiautomatic and clinical plans were equivalent in terms of primary target volume coverage and organ at risk

  7. Conceptual design of hollow electron lenses for beam halo control in the Large Hadron Collider

    CERN Document Server

    Stancari, Giulio; Valishev, Alexander; Bruce, Roderik; Redaelli, Stefano; Rossi, Adriana; Salvachua Ferrando, Belen

    2014-01-01

    Collimation with hollow electron beams is a technique for halo control in high-power hadron beams. It is based on an electron beam (possibly pulsed or modulated in intensity) guided by strong axial magnetic fields which overlaps with the circulating beam in a short section of the ring. The concept was tested experimentally at the Fermilab Tevatron collider using a hollow electron gun installed in one of the Tevatron electron lenses. Within the US LHC Accelerator Research Program (LARP) and the European FP7 HiLumi LHC Design Study, we are proposing a conceptual design for applying this technique to the Large Hadron Collider at CERN. A prototype hollow electron gun for the LHC was built and tested. The expected performance of the hollow electron beam collimator was based on Tevatron experiments and on numerical tracking simulations. Halo removal rates and enhancements of halo diffusivity were estimated as a function of beam and lattice parameters. Proton beam core lifetimes and emittance growth rates were check...

  8. Development of aromatic VOC control technology by electron beam hybrid

    International Nuclear Information System (INIS)

    Kim, Jo-Chun; Kim, Ki-Joon

    2006-01-01

    As a fundamental study, the decomposition of volatile organic compounds (VOCs) using electron beam (EB) irradiation has been extensively investigated. EB treatments of VOCs such as toluene and styrene are discussed. The degradation characteristics were intensively investigated under various concentrations and irradiation doses to determine and improve VOC removal efficiencies. This work illustrates that the removal efficiencies of aromatic VOCs generally increase as their concentrations decrease and the irradiation doses increase. Based on these basic studies, it was found that by-products produced from EB irradiation of VOCs would cause a secondary pollution problem. Therefore, a novel hybrid technology has been applied to control aromatic VOC emissions by annexing the catalyst technique with conventional treatment study using EB technology. The experiments were carried out using a bench-scale at first, then a pilot-scale system was followed. Toluene was selected as a typical VOC for EB hybrid control to investigate by-products, effects of ceramic and catalyst, and factors affecting overall efficiency of degradation. It was concluded that VOCs could be destroyed more effectively by a novel hybrid system than single EB irradiation. (author)

  9. Magnet power supply and beam line control for a secondary beam line K6

    International Nuclear Information System (INIS)

    Suzuki, Y.; Takasaki, M.; Minakawa, M.; Ishii, H.; Kato, Y.; Ieiri, M.; Tanaka, K.H.; Noumi, H.; Yamanoi, Y.

    1992-01-01

    K6 is a secondary separated-beam line with momentum range up to 2.0 GeV/c in the north experimental hall at the KEK 12 GeV Proton Synchrotron (KEK-PS). On the construction, newly developed magnet power supplies (MPSs), in each of them a microprocessor is embedded, are introduced. The features of the MPS are as follows: 1, The MPS is connected to an upper-level beam line controller (BLC) by GPIB highway for exchanging simple messages. 2, All the operations of the MPS are supervised by the microprocessor, which has its individual parameters and fault messages. It reduces the load of the upper-level controller. 3, The MPS has functions to inspect itself and to report the result. It saves much time and labor of maintenance. (author)

  10. Beam control in the ETA-II linear induction accelerator

    International Nuclear Information System (INIS)

    Chen, Y.J.

    1992-01-01

    Corkscrew beam motion is caused by chromatic aberration and misalignment of a focusing system. We have taken some measures to control the corkscrew motion on the ETA-II induction accelerator. To minimize chromatic aberration, we have developed an energy compensation scheme which reduces energy sweep and differential phase advance within a beam pulse. To minimize the misalignment errors, we have developed a time-independent steering algorithm which minimizes the observed corkscrew amplitude averaged over the beam pulse. The steering algorithm can be used even if the monitor spacing is much greater than the system's cyclotron wavelength and the corkscrew motion caused by a given misaligned magnet is fully developed, i.e., the relative phase advance is greater than 2π. (Author) 5 figs., 11 refs

  11. Beam - and drive - controlled amplifier for the ISABELLE accelerating system

    International Nuclear Information System (INIS)

    Luccio, A.; Puglisi, M.

    1981-01-01

    The need of very low output impedance rf systems for heavy particle accelerators has led to the development of very sophisticated amplifier configurations. Among them, the use of a common-anode final amplifier seems most promising. If the output impedance is defined in the Thevenin Theorem sense, then class-A operation seems unavoidable. However, for particle dynamics only the voltage induced by the beam is of real concern and voltage requirements do not necessarily demand a time invariant output impedance. These considerations led to investigation of the conditions that must be met to obtain control over the beam-induced voltage. It was possible to demonstrate that in the common anode case the induced voltage can be largely independent of the bias applied to the final tube, if the beam loading is very strong

  12. Neutral beam control systems for the Tandem Mirror Experiment

    International Nuclear Information System (INIS)

    Ross, R.I.

    1979-01-01

    The Tandem Mirror Experiment (TMX) is presently developing the technology and approaches which will be used in larger fusion systems. This paper describes some of the designs which were used in creating the control system for the TMX neutral beams. To create a system of controls that would work near these large, rapid switching current sources required a mixture of different technologies: fiberoptic data transmission, printed circuit and wirewrap techniques, etc

  13. Randomized Control Trial: Evaluating Aluminum-Based Antiperspirant Use, Axilla Skin Toxicity, and Reported Quality of Life in Women Receiving External Beam Radiotherapy for Treatment of Stage 0, I, and II Breast Cancer

    International Nuclear Information System (INIS)

    Watson, Linda C.; Gies, Donna; Thompson, Emmanuel; Thomas, Bejoy

    2012-01-01

    Purpose: Standard skin care instructions regarding the use of antiperspirants during radiotherapy to the breast varies across North America. Women have articulated that when instructed to not use antiperspirant, the potential for body odor is distressing. Historical practices and individual opinions have often guided practice in this field. The present study had 2 purposes. To evaluate whether the use of aluminum-based antiperspirant while receiving external beam radiotherapy for stage 0, I, or II breast cancer will increase axilla skin toxicity and to evaluate whether the use of antiperspirant during external beam radiotherapy improves quality of life. Methods: A total of 198 participants were randomized to either the experimental group (antiperspirant) or control group (standard care-wash only). The skin reactions in both groups were measured weekly and 2 weeks after treatment using the National Cancer Institute Common Toxicity Criteria Adverse Events, version 3, toxicity grading criteria. Both groups completed the Functional Assessment for Chronic Illness Therapy’s questionnaire for the breast population quality of life assessment tool, with additional questions evaluating the effect of underarm antiperspirant use on quality of life before treatment, immediately after treatment, and 2 weeks after treatment during the study. Results: The skin reaction data were analyzed using the generalized estimating equation. No statistically significant difference was seen in the skin reaction between the 2 groups over time. The quality of life data also revealed no statistically significant difference between the 2 groups over time. Conclusions: Data analysis indicates that using antiperspirant routinely during external beam radiotherapy for Stage 0, I, or II breast cancer does not affect the intensity of the skin reaction or the self-reported quality of life. This evidence supports that in this particular population, there is no purpose to restrict these women from using

  14. Randomized Control Trial: Evaluating Aluminum-Based Antiperspirant Use, Axilla Skin Toxicity, and Reported Quality of Life in Women Receiving External Beam Radiotherapy for Treatment of Stage 0, I, and II Breast Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Watson, Linda C., E-mail: Linda.watson@albertahealthservices.ca [Department of Interdisciplinary Practice, Community Oncology, Alberta Health Services-Cancer Care, Calgary, AB (Canada); Gies, Donna [Department of Radiation Oncology Nursing, Tom Baker Cancer Centre, Alberta Health Services-Cancer Care, Calgary, AB (Canada); Thompson, Emmanuel [Department of Mathematics and Statistics, University of Calgary Faculty of Science, Calgary, AB (Canada); Thomas, Bejoy [Department of Psychosocial Resources, Tom Baker Cancer Centre, Alberta Health Services-Cancer Care, Calgary, AB (Canada); Department of Psychosocial Oncology, University of Calgary Faculty of Medicine, Calgary, AB (Canada)

    2012-05-01

    Purpose: Standard skin care instructions regarding the use of antiperspirants during radiotherapy to the breast varies across North America. Women have articulated that when instructed to not use antiperspirant, the potential for body odor is distressing. Historical practices and individual opinions have often guided practice in this field. The present study had 2 purposes. To evaluate whether the use of aluminum-based antiperspirant while receiving external beam radiotherapy for stage 0, I, or II breast cancer will increase axilla skin toxicity and to evaluate whether the use of antiperspirant during external beam radiotherapy improves quality of life. Methods: A total of 198 participants were randomized to either the experimental group (antiperspirant) or control group (standard care-wash only). The skin reactions in both groups were measured weekly and 2 weeks after treatment using the National Cancer Institute Common Toxicity Criteria Adverse Events, version 3, toxicity grading criteria. Both groups completed the Functional Assessment for Chronic Illness Therapy's questionnaire for the breast population quality of life assessment tool, with additional questions evaluating the effect of underarm antiperspirant use on quality of life before treatment, immediately after treatment, and 2 weeks after treatment during the study. Results: The skin reaction data were analyzed using the generalized estimating equation. No statistically significant difference was seen in the skin reaction between the 2 groups over time. The quality of life data also revealed no statistically significant difference between the 2 groups over time. Conclusions: Data analysis indicates that using antiperspirant routinely during external beam radiotherapy for Stage 0, I, or II breast cancer does not affect the intensity of the skin reaction or the self-reported quality of life. This evidence supports that in this particular population, there is no purpose to restrict these women from

  15. Beam Based RF Voltage Measurements and Longitudinal Beam Tomography at the Fermilab Booster

    Energy Technology Data Exchange (ETDEWEB)

    Bhat, C. M. [Fermilab; Bhat, S. [Fermilab

    2017-10-19

    Increasing proton beam power on neutrino production targets is one of the major goals of the Fermilab long term accelerator programs. In this effort, the Fermilab 8 GeV Booster synchrotron plays a critical role for at least the next two decades. Therefore, understanding the Booster in great detail is important as we continue to improve its performance. For example, it is important to know accurately the available RF power in the Booster by carrying out beam-based measurements in order to specify the needed upgrades to the Booster RF system. Since the Booster magnetic field is changing continuously measuring/calibrating the RF voltage is not a trivial task. Here, we present a beam based method for the RF voltage measurements. Data analysis is carried out using computer programs developed in Python and MATLAB. The method presented here is applicable to any RCS which do not have flat-bottom and flat-top in the acceleration magnetic ramps. We have also carried out longitudinal beam tomography at injection and extraction energies with the data used for RF voltage measurements. Beam based RF voltage measurements and beam tomography were never done before for the Fermilab Booster. The results from these investigations will be very useful in future intensity upgrades.

  16. Ionscan: scanning and control software for proton beam writing

    International Nuclear Information System (INIS)

    Bettiol, A.A.; Udalagama, C.N.B.; Kan, J.A. van; Watt, F.

    2005-01-01

    The proton beam writing technique relies on a precise beam scanning and control system that offers a simple yet flexible interface for the fabrication and design of microstructures. At the Centre for Ion Beam Applications, National University of Singapore, we have developed a suite of programs, collectively known as Ionscan, that cater for the specific needs of proton beam writing. The new version of Ionscan is developed using the Microsoft Visual C++. NET development environment in conjunction with a National Instruments analog output card and NI-DAQ drivers. With the benefit of the experience gained in proton beam writing over the years, numerous enhancements and new features have been added to the scanning software since the first version of the program that was developed using LabVIEW [A.A. Bettiol, J.A. van Khan, T.C. Sum, F. Watt, Nucl. Instr. and Meth. B 181 (2001) 49]. These include the ability to perform combined stage and magnetic (or electrostatic) scanning, which is particularly useful for the fabrication of long waveguides and microfluidic channels over lengths of up to 2.5 cm. Other enhancements include the addition of the Ionutils program which gives the user the ability to design basic structures using an ASCII file format that was developed. This format contains basic information on the shape to be irradiated including the way in which it is scanned

  17. Open-loop position tracking control of a piezoceramic flexible beam using a dynamic hysteresis compensator

    International Nuclear Information System (INIS)

    Nguyen, Phuong-Bac; Choi, Seung-Bok

    2010-01-01

    This paper proposes a novel hysteresis compensator to enhance control accuracy in open-loop position tracking control of a piezoceramic flexible beam. The proposed hysteresis compensator consists of two components: a rate-independent hysteresis compensator and a nonlinear filter. The compensator is formulated based on the inverse Preisach model, while the weight coefficients of the filter are identified adaptively using a recursive least square (RLS) algorithm. In this work, two dynamic hysteresis compensators (or rate-independent hysteresis compensators) are developed by adopting two different nonlinear filters: Volterra and bilinear filters. In order to demonstrate the improved control accuracy of the proposed dynamic compensators, a flexible beam associated with the piezoceramic actuator is modeled using the finite element method (FEM) and Euler–Bernoulli beam theory. The beam model is then integrated with the proposed hysteresis model to achieve accurate position tracking control at the tip of the beam. An experimental investigation on the tip position tracking control is undertaken by realizing three different hysteresis compensators: a rate-independent hysteresis compensator, a rate-dependent hysteresis compensator with a Volterra nonlinear filter and a rate-independent hysteresis compensator with a bilinear nonlinear filter. It is shown that the proposed dynamic hysteresis compensators can provide much better tracking control accuracy than conventional rate-independent hysteresis compensators

  18. An Electron Beam Profile Instrument Based on FBGs

    Directory of Open Access Journals (Sweden)

    Dan Sporea

    2014-08-01

    Full Text Available Along with the dose rate and the total irradiation dose measurements, the knowledge of the beam localization and the beam profile/energy distribution in the beam are parameters of interest for charged particle accelerator installations when they are used in scientific investigations, industrial applications or medical treatments. The transverse profile of the beam, its position, its centroid location, and its focus or flatness depend on the instrument operating conditions or on the beam exit setup. Proof-of-concept of a new type of charged particle beam diagnostics based on fiber Bragg gratings (FBGs was demonstrated. Its operating principle relies on the measurement of the peak wavelength changes for an array of FBG sensors as function of the temperature following the exposure to an electron beam. Periodically, the sensor irradiation is stopped and the FBG are force cooled to a reference temperature with which the temperature influencing each sensor during beam exposure is compared. Commercially available FBGs, and FBGs written in radiation resistant optical fibers, were tested under electron beam irradiation in order to study their possible use in this application.

  19. Characterization and control of femtosecond electron and X-ray beams at free-electron lasers

    Energy Technology Data Exchange (ETDEWEB)

    Behrens, Christopher

    2012-11-15

    X-ray free-electron lasers (FELs) open up new frontiers in photon science, and in order to take full advantage of these unique accelerator-based light sources, the characterization and control of the femtosecond electron and X-ray beams is essential. Within this cumulative thesis, recent results achieved within the active research field of femtosecond electron and X-ray beams at FELs are reported.The basic principles of X-ray FELs are described, and concepts of longitudinal electron beam diagnostics with femtosecond accuracy are covered. Experimental results obtained with a transverse deflecting structure (TDS) and spectroscopy of coherent terahertz radiation are presented, and the suppression of coherent optical radiation effects, required for diagnostics utilizing a TDS, is demonstrated. Control of the longitudinal phase space by using multiple radio frequencies for longitudinal electron beam tailoring is presented, and a new technique of reversible electron beam heating with two TDSs is described. For the characterization of femtosecond X-ray pulses, a novel method based on dedicated longitudinal phase space diagnostics for electron beams is introduced, and recent measurements with a streaking technique using external terahertz fields are presented.

  20. Characterization and control of femtosecond electron and X-ray beams at free-electron lasers

    International Nuclear Information System (INIS)

    Behrens, Christopher

    2012-11-01

    X-ray free-electron lasers (FELs) open up new frontiers in photon science, and in order to take full advantage of these unique accelerator-based light sources, the characterization and control of the femtosecond electron and X-ray beams is essential. Within this cumulative thesis, recent results achieved within the active research field of femtosecond electron and X-ray beams at FELs are reported.The basic principles of X-ray FELs are described, and concepts of longitudinal electron beam diagnostics with femtosecond accuracy are covered. Experimental results obtained with a transverse deflecting structure (TDS) and spectroscopy of coherent terahertz radiation are presented, and the suppression of coherent optical radiation effects, required for diagnostics utilizing a TDS, is demonstrated. Control of the longitudinal phase space by using multiple radio frequencies for longitudinal electron beam tailoring is presented, and a new technique of reversible electron beam heating with two TDSs is described. For the characterization of femtosecond X-ray pulses, a novel method based on dedicated longitudinal phase space diagnostics for electron beams is introduced, and recent measurements with a streaking technique using external terahertz fields are presented.

  1. DIII-D Neutral Beam control system operator interface

    International Nuclear Information System (INIS)

    Harris, J.J.; Campbell, G.L.

    1993-10-01

    A centralized graphical user interface has been added to the DIII-D Neutral Beam (NB) control systems for status monitoring and remote control applications. This user interface provides for automatic data acquisition, alarm detection and supervisory control of the four NB programmable logic controllers (PLC) as well as the Mode Control PLC. These PLCs are used for interlocking, control and status of the NB vacuum pumping, gas delivery, and water cooling systems as well as beam mode status and control. The system allows for both a friendly user interface as well as a safe and convenient method of communicating with remote hardware that formerly required interns to access. In the future, to enable high level of control of PLC subsystems, complete procedures is written and executed at the touch of a screen control panel button. The system consists of an IBM compatible 486 computer running the FIX DMACS trademark for Windows trademark data acquisition and control interface software, a Texas Instruments/Siemens communication card and Phoenix Digital optical communications modules. Communication is achieved via the TIWAY (Texas Instruments protocol link utilizing both fiber optic communications and a copper local area network (LAN). Hardware and software capabilities will be reviewed. Data and alarm reporting, extended monitoring and control capabilities will also be discussed

  2. Quadrupole beam-based alignment in the RHIC interaction regions

    Energy Technology Data Exchange (ETDEWEB)

    Ziegler, J.; Satogata, T.

    2011-03-28

    Continued beam-based alignment (BBA) efforts have provided significant benefit to both heavy ion and polarized proton operations at RHIC. Recent studies demonstrated previously unknown systematic beam position monitor (BPM) offset errors and produced accurate measurements of individual BPM offsets in the experiment interaction regions. Here we describe the algorithm used to collect and analyze data during the 2010 and early 2011 RHIC runs and the results of these measurements. BBA data has been collected over the past two runs for all three of the active experimental IRs at RHIC, updating results from the 2005 run which were taken with incorrectly installed offsets. The technique was successfully applied to expose a systematic misuse of the BPM survey offsets in the control system. This is likely to benefit polarized proton operations as polarization transmission through acceleration ramps depends on RMS orbit control in the arcs, but a quantitative understanding of its impact is still under active investigation. Data taking is ongoing as are refinements to the BBA technique aimed at reducing systematic errors and properly accounting for dispersive effects. Further development may focus on non-triplet BPMs such as those located near snakes, or arc quadrupoles that do not have individually shunted power supplies (a prerequisite for the current method) and as such, will require a modified procedure.

  3. Performance and perspectives of the diamond based Beam Condition Monitor for beam loss monitoring at CMS

    CERN Document Server

    AUTHOR|(CDS)2080862

    2015-01-01

    At CMS, a beam loss monitoring system is operated to protect the silicon detectors from high particle rates, arising from intense beam loss events. As detectors, poly-crystalline CVD diamond sensors are placed around the beam pipe at several locations inside CMS. In case of extremely high detector currents, the LHC beams are automatically extracted from the LHC rings.Diamond is the detector material of choice due to its radiation hardness. Predictions of the detector lifetime were made based on FLUKA monte-carlo simulations and irradiation test results from the RD42 collaboration, which attested no significant radiation damage over several years.During the LHC operational Run1 (2010 â?? 2013), the detector efficiencies were monitored. A signal decrease of about 50 times stronger than expectations was observed in the in-situ radiation environment. Electric field deformations due to charge carriers, trapped in radiation induced lattice defects, are responsible for this signal decrease. This so-called polarizat...

  4. Beam-based alignment of CLIC drive beam decelerator using girders movers

    CERN Document Server

    Sterbini, G

    2011-01-01

    The CLIC drive beams will provide the rf power to accelerate the colliding beams: in order to reach the design performance, an efficient transport of the drive beam has to be ensured in spite of its challenging energy spread and large current intensity. As shown in previous studies, the specifications can be met by coupling a convenient optics design with the state-of-the-art of pre-alignment and beambased alignment techniques. In this paper we consider a novel beam-based alignment scheme that does not require quadrupole movers or dipole correctors but uses the motors already foreseen for the pre-alignment system. This implies potential savings in terms of complexity and cost at the expense of the alignment flexibility: the performance, limitations and sensitivity to pre-alignment tolerances of this method are discussed.

  5. Simulation Studies of Beam-Beam Effects of a Ring-Ring Electron-Ion Collider Based on CEBAF

    Energy Technology Data Exchange (ETDEWEB)

    Yuhong Zhang,Ji Qiang

    2009-05-01

    The collective beam-beam effect can potentially cause a rapid growth of beam sizes and reduce the luminosity of a collider to an unacceptably low level. The ELIC, a proposed ultra high luminosity electron-ion collider based on CEBAF, employs high repetition rate crab crossing colliding beams with very small bunch transverse sizes and very short bunch lengths, and collides them at up to 4 interaction points with strong final focusing. All of these features can make the beam-beam effect challenging. In this paper, we present simulation studies of the beam-beam effect in ELIC using a self-consistent strong-strong beam-beam simulation code developed at Lawrence Berkeley National Laboratory. This simulation study is used for validating the ELIC design and for searching for an optimal parameter set.

  6. Equilibrium-Based Nonhomogeneous Anisotropic Beam Element

    DEFF Research Database (Denmark)

    Krenk, Steen; Couturier, Philippe

    2017-01-01

    The stiffness matrix and the nodal forces associated with distributed loads are obtained for a nonhomogeneous anisotropic elastic beam element by the use of complementary energy. The element flexibility matrix is obtained by integrating the complementary-energy density corresponding to six beam...... equilibrium states, and then inverted and expanded to provide the element-stiffness matrix. Distributed element loads are represented via corresponding internal-force distributions in local equilibrium with the loads. The element formulation does not depend on assumed shape functions and can, in principle......, include any variation of cross-sectional properties and load variation, provided that these are integrated with sufficient accuracy in the process. The ability to represent variable cross-sectional properties, coupling from anisotropic materials, and distributed element loads is illustrated by numerical...

  7. Reactor - and accelerator-based filtered beams

    International Nuclear Information System (INIS)

    Mill, A.J.; Harvey, J.R.

    1980-01-01

    The neutrons produced in high flux nuclear reactors and in accelerator, induced fission and spallation reactions, represent the most intense sources of neutrons available for research. However, the neutrons from these sources are not monoenergetic, covering the broad range extending from 10 -3 eV up to 10 7 eV or so. In order to make quantitative measurements of the effects of neutrons and their dependence on neutron energy it is desirable to have mono-energetic neutron sources. The paper describes briefly methods of obtaining mono-energetic neutrons and different methods of filtration. This is followed by more detailed discussion of neutron window filters and a summary of the filtered beam facilities using this technique. The review concludes with a discussion of the main applications of filtered beams and their present and future importance

  8. Image reconstruction of cyclotron beam based on Hopfield network

    Energy Technology Data Exchange (ETDEWEB)

    Okamura, Tetsuya; Murakami, Thoru; Tanizaki, Naoaki (Sumitomo Heavy Industries, Tanashi, Tokyo (Japan). Systems Engineering Lab.)

    1991-12-01

    This paper describes a beam image reconstruction method based on Hopfield neural networks. The images of beam emitted from cyclotrons are measured as three projection patterns by 3-wire beam sensors. The reconstruction of beam image is necessary because the measured projection patterns are not easy to understand for inexperienced operators. First, the energy function is defined using the measured projection patterns as constraints. Then surface tension terms, which make the surface area minimal, are added to it in order to generate smooth images. The weights of links of the Hopfield network are determined by the coefficients of the energy function. Through the convergence of the network, beam images which satisfy the projection patterns and look natural for human sense can be reconstructed. (author).

  9. Recent progress in tailoring trap-based positron beams

    Energy Technology Data Exchange (ETDEWEB)

    Natisin, M. R.; Hurst, N. C.; Danielson, J. R.; Surko, C. M. [Physics Department, University of California, San Diego La Jolla CA 92093-0319 (United States)

    2013-03-19

    Recent progress is described to implement two approaches to specially tailor trap-based positron beams. Experiments and simulations are presented to understand the limits on the energy spread and pulse duration of positron beams extracted from a Penning-Malmberg (PM) trap after the particles have been buffer-gas cooled (or heated) in the range of temperatures 1000 {>=} T {>=} 300 K. These simulations are also used to predict beam performance for cryogenically cooled positrons. Experiments and simulations are also presented to understand the properties of beams formed when plasmas are tailored in a PM trap in a 5 tesla magnetic field, then non-adiabatically extracted from the field using a specially designed high-permeability grid to create a new class of electrostatically guided beams.

  10. Halo control, beam matching, and new dynamical variables for beam distributions

    International Nuclear Information System (INIS)

    Lysenko, W.; Parsa, Z.

    1997-01-01

    We present the status of our work on physics models that relate release to the understanding and control of beam halo, which is a cause of particle loss in high power ion linear accelerators. We can minimize these particle losses, even in the presence of nonlinearities, by ensuring the beam is matched to high order. Our goal is to determine new dynamical variables that enable us to more directly solve for the evolution of the halo. We considered moments and several new variables, using a Lie-Poisson formulation whenever possible. Using symbolic techniques, we computed high-order matches and mode invariants (analogs of moment invariants) in the new variables. A promising new development developments is that of the variables we call weighted moments, which allow us to compute high-order nonlinear effects (like halos) while making use of well-developed existing results and computational techniques developed for studying first order effects. copyright 1997 American Institute of Physics

  11. Particle beam digital phase control system for COSY

    International Nuclear Information System (INIS)

    Schnase, A.

    1994-02-01

    Particle accelerators require that the orbit of the charged particles in the vacuum chamber is controlled to fulfil narrow limits. This is done by magnetic deflection systems and exactly adjusted rf-acceleration. Up to now the necessary control-functions were realised with analogue parts. This work describes a digital phase control system that works in real time and is used with the proton accelerator COSY. The physical design of the accelerator sets the accuracy-specifications of the revolution frequency (<1 Hz in the whole range from 400 kHz to 1.6 MHz), the phase-difference (<0.01 ), the signal-to-noise-ratio (<-60 dBc) and the update rate (<1 μs) of the parameters. In a typical operation the beam is first bunched and synchronised to the reference oscillator. After that the beam influences the rf-system with the help of charge detectors and now the rf-systems will be synchronised with the bunched beam. This control-loop is modelled and simulated with PSPICE. (orig.)

  12. Adaptive radiotherapy based on contrast enhanced cone beam CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Soevik, Aaste; Skogmo, Hege K. (Dept. of Companion Animal Clinical Sciences, Norwegian School of Veterinary Science, Oslo (Norway)), E-mail: aste.sovik@nvh.no; Roedal, Jan (Dept. of Companion Animal Clinical Sciences, Norwegian School of Veterinary Science, Oslo (Norway)); Lervaag, Christoffer; Eilertsen, Karsten; Malinen, Eirik (Dept. of Medical Physics, The Norwegian Radium Hospital, Oslo Univ. Hospital, Oslo (Norway))

    2010-10-15

    Cone beam CT (CBCT) imaging has become an integral part of radiation therapy, with images typically used for offline or online patient setup corrections based on bony anatomy co-registration. Ideally, the co-registration should be based on tumor localization. However, soft tissue contrast in CBCT images may be limited. In the present work, contrast enhanced CBCT (CECBCT) images were used for tumor visualization and treatment adaptation. Material and methods. A spontaneous canine maxillary tumor was subjected to repeated cone beam CT imaging during fractionated radiotherapy (10 fractions in total). At five of the treatment fractions, CECBCT images, employing an iodinated contrast agent, were acquired, as well as pre-contrast CBCT images. The tumor was clearly visible in post-contrast minus pre-contrast subtraction images, and these contrast images were used to delineate gross tumor volumes. IMRT dose plans were subsequently generated. Four different strategies were explored: 1) fully adapted planning based on each CECBCT image series, 2) planning based on images acquired at the first treatment fraction and patient repositioning following bony anatomy co-registration, 3) as for 2), but with patient repositioning based on co-registering contrast images, and 4) a strategy with no patient repositioning or treatment adaptation. The equivalent uniform dose (EUD) and tumor control probability (TCP) calculations to estimate treatment outcome for each strategy. Results. Similar translation vectors were found when bony anatomy and contrast enhancement co-registration were compared. Strategy 1 gave EUDs closest to the prescription dose and the highest TCP. Strategies 2 and 3 gave EUDs and TCPs close to that of strategy 1, with strategy 3 being slightly better than strategy 2. Even greater benefits from strategies 1 and 3 are expected with increasing tumor movement or deformation during treatment. The non-adaptive strategy 4 was clearly inferior to all three adaptive strategies

  13. Adaptive radiotherapy based on contrast enhanced cone beam CT imaging

    International Nuclear Information System (INIS)

    Soevik, Aaste; Skogmo, Hege K.; Roedal, Jan; Lervaag, Christoffer; Eilertsen, Karsten; Malinen, Eirik

    2010-01-01

    Cone beam CT (CBCT) imaging has become an integral part of radiation therapy, with images typically used for offline or online patient setup corrections based on bony anatomy co-registration. Ideally, the co-registration should be based on tumor localization. However, soft tissue contrast in CBCT images may be limited. In the present work, contrast enhanced CBCT (CECBCT) images were used for tumor visualization and treatment adaptation. Material and methods. A spontaneous canine maxillary tumor was subjected to repeated cone beam CT imaging during fractionated radiotherapy (10 fractions in total). At five of the treatment fractions, CECBCT images, employing an iodinated contrast agent, were acquired, as well as pre-contrast CBCT images. The tumor was clearly visible in post-contrast minus pre-contrast subtraction images, and these contrast images were used to delineate gross tumor volumes. IMRT dose plans were subsequently generated. Four different strategies were explored: 1) fully adapted planning based on each CECBCT image series, 2) planning based on images acquired at the first treatment fraction and patient repositioning following bony anatomy co-registration, 3) as for 2), but with patient repositioning based on co-registering contrast images, and 4) a strategy with no patient repositioning or treatment adaptation. The equivalent uniform dose (EUD) and tumor control probability (TCP) calculations to estimate treatment outcome for each strategy. Results. Similar translation vectors were found when bony anatomy and contrast enhancement co-registration were compared. Strategy 1 gave EUDs closest to the prescription dose and the highest TCP. Strategies 2 and 3 gave EUDs and TCPs close to that of strategy 1, with strategy 3 being slightly better than strategy 2. Even greater benefits from strategies 1 and 3 are expected with increasing tumor movement or deformation during treatment. The non-adaptive strategy 4 was clearly inferior to all three adaptive strategies

  14. Beam loss control on the ISIS synchrotron simulations, measurements, upgrades

    CERN Document Server

    Warsop, C M

    2003-01-01

    The ISIS 800 MeV proton synchrotron presently provides 2.5*10/sup 13/ protons per pulse at 50 Hz, corresponding to a mean power of 160 kW. A dual harmonic RF system upgrade, now being installed, is expected to increase the intensity and power to about 3.75*10/sup 13/ ppp and 240 kW respectively. This paper describes work presently underway to understand and optimise beam loss control, which is a dominant factor determining operational performance. The main features of the collimation system are described, and Monte Carlo simulations of the loss control process are used to understand variations of efficiency with beam loss mode (growth rate, plane). Results of simulations are compared with measurements and operational data. Improvements to measurements are also outlined.

  15. Effect of electron cyclotron beam width to neoclassical tearing mode stabilization by minimum seeking control in ITER

    Science.gov (United States)

    Park, Minho; Na, Yong-Su; Seo, Jaemin; Kim, M.; Kim, Kyungjin

    2018-01-01

    We report the effect of the electron cyclotron (EC) beam width on the full suppression time of neoclassical tearing mode (NTM) using the finite difference method (FDM) based minimum seeking controller in ITER. An integrated numerical system is setup for time-dependent simulations of the NTM evolution in ITER by solving the modified Rutherford equation together with the plasma equilibrium, transport, and EC heating and current drive. The calculated magnetic island width and growth rate is converted to the Mirnov diagnostic signal as an input to the controller to mimic the real experiment. In addition, 10% of the noise is enforced to this diagnostic signal to evaluate the robustness of the controller. To test the dependency of the NTM stabilization time on the EC beam width, the EC beam width scan is performed for a perfectly aligned case first, then for cases with the feedback control using the minimum seeking controller. When the EC beam is perfectly aligned, the narrower the EC beam width, the smaller the NTM stabilization time is observed. As the beam width increases, the required EC power increases exponentially. On the other hand, when the minimum seeking controller is applied, NTM stabilization sometimes fails as the EC beam width decreases. This is consistently observed in the simulation with various representations of the noise as well as without the noise in the Mirnov signal. The higher relative misalignment, misalignment divided by the beam width, is found to be the reason for the failure with the narrower beam widths. The EC stabilization effect can be lower for the narrower beam widths than the broader ones even at the same misalignment due to the smaller ECCD at the island O-point. On the other hand, if the EC beam is too wide, the NTM stabilization time takes too long. Accordingly, the optimal EC beam width range is revealed to exist in the feedback stabilization of NTM.

  16. Real-time beam tracing for control of the deposition location of electron cyclotron waves

    Energy Technology Data Exchange (ETDEWEB)

    Reich, M., E-mail: matthias.reich@ipp.mpg.de; Bilato, R.; Mszanowski, U.; Poli, E.; Rapson, C.; Stober, J.; Volpe, F.; Zille, R.

    2015-11-15

    Highlights: • We successfully integrated a real-time EC beam tracing code at ASDEX Upgrade. • The calculation of EC beam deposition location is fast enough for control purposes. • The accuracy of the deposition location calculation exceeds equivalent measurements. • The implementation method is by design portable to larger fusion devices. - Abstract: Plasma control techniques that use electron cyclotron (EC) resonance heating and current drive such as control of neoclassical tearing modes require accurate control of the deposition location of EC beams. ASDEX Upgrade has successfully implemented a real-time version of the beam-tracing code TORBEAM into its real-time diagnostic system to act as a globally available module that calculates current deposition location and its sensitivity from other real-time diagnostic measurements for all its moveable EC wave launchers. Based on a highly (100×) accelerated version of TORBEAM, the software implementation as a diagnostic process uses parallelization and achieves cycle times of 15–20 ms for determining the radial deposition location of 12 beams in the plasma. This cycle time includes data input–output overhead arising from the use of available real-time signals. The system is by design portable to other machines such as ITER.

  17. Tracking control of a flexible beam by nonlinear boundary feedback

    Directory of Open Access Journals (Sweden)

    Bao-Zhu Guo

    1995-01-01

    Full Text Available This paper is concerned with tracking control of a dynamic model consisting of a flexible beam rotated by a motor in a horizontal plane at the one end and a tip body rigidly attached at the free end. The well-posedness of the closed loop systems considering the dissipative nonlinear boundary feedback is discussed and the asymptotic stability about difference energy of the hybrid system is also investigated.

  18. Spatial Control of Laser Wakefield Accelerated Electron Beams

    Science.gov (United States)

    Maksimchuk, A.; Behm, K.; Zhao, T.; Joglekar, A. S.; Hussein, A.; Nees, J.; Thomas, A. G. R.; Krushelnick, K.; Elle, J.; Lucero, A.; Samarin, G. M.; Sarry, G.; Warwick, J.

    2017-10-01

    The laser wakefield experiments to study and control spatial properties of electron beams were performed using HERCULES laser at the University of Michigan at power of 100 TW. In the first experiment multi-electron beam generation was demonstrated using co-propagating, parallel laser beams with a π-phase shift mirror and showing that interaction between the wakefields can cause injection to occur for plasma and laser parameters in which a single wakefield displays no significant injection. In the second experiment a magnetic triplet quadrupole system was used to refocus and stabilize electron beams at the distance of 60 cm from the interaction region. This produced a 10-fold increase in remote gamma-ray activation of 63Cu using a lead converter. In the third experiment measurements of un-trapped electrons with high transverse momentum produce a 500 mrad (FWHM) ring. This ring is formed by electrons that receive a forward momentum boost by traversing behind the bubble and its size is inversely proportional to the plasma density. The characterization of divergence and charge of this electron ring may reveal information about the wakefield structure and trapping potential. Supported by U.S. Department of Energy and the National Nuclear Security Administration and Air Force Office of Scientific Research.

  19. First experiences of beam presence detection based on dedicated beam position monitors

    International Nuclear Information System (INIS)

    Jalal, A.; Gabourin, S.; Gasior, M.; Todd, B.

    2012-01-01

    High intensity particle beam injection into the LHC is only permitted when a low intensity pilot beam is already circulating in the LHC. This requirement addresses some of the risks associated with high intensity injection, and is enforced by a so-called Beam Presence Flag (BPF) system which is part of the interlock chain between the LHC and its injector complex. For the 2010 LHC run, the detection of the presence of this pilot beam was implemented using the LHC Fast Beam Current Transformer (FBCT) system. However, the primary function of the FBCTs, that is reliable measurement of beam currents, did not allow the BPF system to satisfy all quality requirements of the LHC Machine Protection System (MPS). Safety requirements associated with high intensity injections triggered the development of a dedicated system, based on Beam Position Monitors (BPM). This system was meant to work first in parallel with the FBCT BPF system and eventually replace it. At the end of 2010 and in 2011, this new BPF implementation based on BPMs was designed, built, tested and deployed. This paper reviews both the FBCT and BPM implementation of the BPF system, outlining the changes during the transition period. The paper briefly describes the testing methods, focuses on the results obtained from the tests performed during the end of 2010 LHC run and shows the changes made for the BPM BPF system deployment in LHC in 2011. Whilst the system has been proved to work with a threshold of 6*10 8 charges, it has been implemented with a threshold of 2*10 9 charges to protect the LHC. (authors)

  20. Performance based analysis of hidden beams in reinforced concrete structures

    Directory of Open Access Journals (Sweden)

    Helou Samir H.

    2014-01-01

    Full Text Available Local and perhaps regional vernacular reinforced concrete building construction leans heavily against designing slabs with imbedded hidden beams for flooring systems in most structures including major edifices. The practice is distinctive in both framed and in shear wall structures. Hidden beams are favoured structural elements due to their many inherent features that characterize them; they save on floor height clearance; they also save on formwork, labour and material cost. Moreover, hidden beams form an acceptable aesthetic appearance that does not hinder efficient interior space partitioning. Such beams have the added advantage of clearing the way for horizontal electromechanical ductwork. However, seismic considerations, in all likelihood, are seldom seriously addressed. The mentioned structural system of shallow beams is adopted in ribbed slabs, waffle slabs and at times with solid slabs. Ribbed slabs and waffle slabs are more prone to hidden beam inclusion due to the added effective height of the concrete section. Due to the presence of a relatively high reinforcement ratio at the joints the sections at such location tend to become less ductile with unreliable contribution to spandrel force resistance. In the following study the structural influence of hidden beams within slabs is investigated. With the primary focus on a performance based analysis of such elements within a structure. This is investigated with due attention to shear wall contribution to the overall behaviour of such structures. Numerical results point in the direction that the function of hidden beams is not as adequate as desired. Therefore it is strongly believed that they are generally superfluous and maybe eliminated altogether. Conversely, shallow beams seem to render the overall seismic capacity of the structure unreliable. Since such an argument is rarely manifested within the linear analysis domain; a pushover analysis exercise is thus mandatory for behaviour

  1. GEM-based beam profile monitors for the antiproton decelerator

    CERN Document Server

    Duarte Pinto, S.; Ropelewski, L.; Spanggaard, J.; Tranquille, G.

    2012-01-01

    The new beam profile measurement for the Antiproton Decelerator (AD) at CERN is based on a single Gas Electron Multiplier (GEM) with a 2D readout structure. This detector is very light, ~0.4% X0, as required by the low energy of the antiprotons, 5.3 MeV. This overcomes the problems previously encountered with multi-wire proportional chambers (MWPC) for the same purpose, where beam interactions with the detector severely affect the obtained profiles. A prototype was installed and successfully tested in late 2010, with another five detectors now installed in the ASACUSA and AEGIS beam lines. We will provide a detailed description of the detector and discuss the results obtained. The success of these detectors in the AD makes GEM-based detectors likely candidates for upgrade of the beam profile monitors in all experimental areas at CERN. The various types of MWPC currently in use are aging and becoming increasingly difficult to maintain.

  2. Quadrupole Beam-Based Alignment in the RHIC Interaction Regions

    Energy Technology Data Exchange (ETDEWEB)

    T. Satogata, J. Ziegler

    2011-03-01

    Continued beam-based alignment (BBA) efforts have provided significant benefit to both heavy ion and polarized proton operations at RHIC. Recent studies demonstrated previously unknown systematic beam position monitor (BPM) offset errors and produced accurate measurements of individual BPM offsets in the experiment interaction regions. Here we describe the algorithm used to collect and analyze data during the 2010 and early 2011 RHIC runs and the results of these measurements.

  3. Planar C-Band Antenna with Electronically Controllable Switched Beams

    Directory of Open Access Journals (Sweden)

    Mariano Barba

    2009-01-01

    Full Text Available The design, manufacturing, and measurements of a switchable-beam antenna at 3.5 GHz for WLL or Wimax base station antennas in planar technology are presented. This antenna performs a discrete beam scan of a 60∘ sector in azimuth and can be easily upgraded to 5 or more steps. The switching capabilities have been implemented by the inclusion of phase shifters based on PIN diodes in the feed network following a strategy that allows the reduction of the number of switches compared to a classic design. The measurements show that the design objectives have been achieved and encourage the application of the acquired experience in antennas for space applications, such as X-band SAR and Ku-band DBS.

  4. Simulation based optimized beam velocity in additive manufacturing

    Science.gov (United States)

    Vignat, Frédéric; Béraud, Nicolas; Villeneuve, François

    2017-08-01

    Manufacturing good parts with additive technologies rely on melt pool dimension and temperature and are controlled by manufacturing strategies often decided on machine side. Strategies are built on beam path and variable energy input. Beam path are often a mix of contour and hatching strategies filling the contours at each slice. Energy input depend on beam intensity and speed and is determined from simple thermal models to control melt pool dimensions and temperature and ensure porosity free material. These models take into account variation in thermal environment such as overhanging surfaces or back and forth hatching path. However not all the situations are correctly handled and precision is limited. This paper proposes new method to determine energy input from full built chamber 3D thermal simulation. Using the results of the simulation, energy is modified to keep melt pool temperature in a predetermined range. The paper present first an experimental method to determine the optimal range of temperature. In a second part the method to optimize the beam speed from the simulation results is presented. Finally, the optimized beam path is tested in the EBM machine and built part are compared with part built with ordinary beam path.

  5. Instrumentation for diagnostics and control of laser-accelerated proton (ion) beams.

    Science.gov (United States)

    Bolton, P R; Borghesi, M; Brenner, C; Carroll, D C; De Martinis, C; Fiorini, Francesca; Flacco, A; Floquet, V; Fuchs, J; Gallegos, P; Giove, D; Green, J S; Green, S; Jones, B; Kirby, D; McKenna, P; Neely, D; Nuesslin, F; Prasad, R; Reinhardt, S; Roth, M; Schramm, U; Scott, G G; Ter-Avetisyan, S; Tolley, M; Turchetti, G; Wilkens, J J

    2014-05-01

    Suitable instrumentation for laser-accelerated proton (ion) beams is critical for development of integrated, laser-driven ion accelerator systems. Instrumentation aimed at beam diagnostics and control must be applied to the driving laser pulse, the laser-plasma that forms at the target and the emergent proton (ion) bunch in a correlated way to develop these novel accelerators. This report is a brief overview of established diagnostic techniques and new developments based on material presented at the first workshop on 'Instrumentation for Diagnostics and Control of Laser-accelerated Proton (Ion) Beams' in Abingdon, UK. It includes radiochromic film (RCF), image plates (IP), micro-channel plates (MCP), Thomson spectrometers, prompt inline scintillators, time and space-resolved interferometry (TASRI) and nuclear activation schemes. Repetition-rated instrumentation requirements for target metrology are also addressed. Copyright © 2013 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  6. Controlled Transverse Blow-up of Highenergy Proton Beams for Aperture Measurements and Loss Maps

    CERN Document Server

    Hӧfle, W; Redaelli, S; Schmidt, R; Valuch, D; Wollmann, D; Zerlauth, M

    2012-01-01

    A technique was developed to blow-up transversely in a controlled way high energy proton beams in the LHC. The technique is based on band limited white noise excitation that is injected into the transverse damper feedback loop. The injected signal can be gated to selectively blow-up individual trains of bunches. The speed of transverse blow-up can be precisely controlled. This opens the possibility to perform safely and efficiently aperture measurements and loss maps with high intensity bunch trains well above stored beam energies that are considered to be safe. In particular, lengthy procedures for measurements at top energy, otherwise requiring multiple fills of individual bunches, can be avoided. In this paper, the method is presented and results from beam measurements are discussed and compared with alternative blowup methods.

  7. System control for the CLIC main beam quadrupole stabilization and nano-positioning

    CERN Document Server

    Janssens, S; Collette, E; Esposito, M; Fernandez Carmona, P; Guinchard, M; Hauviller, C; Kuzmin, A; Leuxe, R; Pfingstner, J; Schulte, D; Snuverink, J

    2011-01-01

    The conceptual design of the active stabilization and nano-positioning of the CLIC main beam quadrupoles was validated in models and experimentally demonstrated on test benches. Although the mechanical vibrations were reduced to within the specification of 1.5 nm at 1 Hz, additional input for the stabilization system control was received fromintegrated luminosity simulations that included the measured stabilization transfer functions. Studies are ongoing to obtain a transfer function which is more compatible with beam based orbit feedback; it concerns the controller layout, new sensors and their combination. In addition, the gain margin must be increased in order to reach the requirements froma higher vibration background. For this purpose, the mechanical support is adapted to raise the frequency of some resonances in the system and the implementation of force sensors is considered. Furthermore, this will increase the speed of repositioning the magnets between beam pulses. This paper describes the improvement...

  8. Laser beam pointing and stabilization by fractional-order PID control: Tuning rule and experiments

    KAUST Repository

    Al-Alwan, Asem Ibrahim Alwan

    2017-10-24

    This paper studies the problem of high-precision positioning of laser beams by using a robust Fractional-Order Proportional-Integral-Derivative (FOPID) controller. The control problem addressed in laser beams aims to maintain the position of the laser beam on a Position Sensing Device (PSD) despite the effects of noise and active disturbances. The FOPID controller is well known for its simplicity with better tuning flexibility along with robustness to noise and output disturbance rejections. Thus, a control strategy based on FOPID to achieve the control objectives has been proposed. The FOPID gains and differentiation orders are optimally tuned in order to fulfill the robustness design specifications by solving a nonlinear optimization problem. A comparison to the conventional Proportional-Integral-Derivative (PID) and robust PID is also provided from simulation and experiment set-up. Due to sensor noise, practical PID controllers that filter the position signal before taking the derivative have been also proposed. Experimental results show that the requirements are totally met for the laser beam platform to be stabilized.

  9. The RF beam control system for the Brookhaven AGS synchrotron

    Energy Technology Data Exchange (ETDEWEB)

    Brennan, J.M.

    1992-01-01

    The new 1.5 GeV Booster synchrotron completes the injector chain for the Relativistic Heavy Ion Collider, RHIC. It enables the AGS to accelerate all heavy ions to 14 GeV/c for collider operation and also in the intensity of the AGS for fixed-target experiments by a factor of four. The ultra-high vacuum enables acceleration of partially stripped ions from the Tandem Van de Graaff to energies sufficient for complete stripping. For high intensities, it accelerates the 200 MeV linac beam in four batches of three bunches per AGS cycle. At 1.5 {times} 10{sup 13} protons per batch, it has the same space charge tune spread as the AGS at 200 MeV. This variety of applications means the Booster must accommodate a very wide range of particle masses and intensities. Since it operates in a Pulse-by-Pulse Modulation mode at 7.5 Hz, the computer controlled functions of time and magnetic field, and the 64 timing triggers of the beam control system take on unique values for each of four PPM users. Beams of {sup 197}Au{sup +33} ions and protons have been accelerated in the same PPM cycle.

  10. The RF beam control system for the Brookhaven AGS synchrotron

    Energy Technology Data Exchange (ETDEWEB)

    Brennan, J.M.

    1992-09-01

    The new 1.5 GeV Booster synchrotron completes the injector chain for the Relativistic Heavy Ion Collider, RHIC. It enables the AGS to accelerate all heavy ions to 14 GeV/c for collider operation and also in the intensity of the AGS for fixed-target experiments by a factor of four. The ultra-high vacuum enables acceleration of partially stripped ions from the Tandem Van de Graaff to energies sufficient for complete stripping. For high intensities, it accelerates the 200 MeV linac beam in four batches of three bunches per AGS cycle. At 1.5 {times} 10{sup 13} protons per batch, it has the same space charge tune spread as the AGS at 200 MeV. This variety of applications means the Booster must accommodate a very wide range of particle masses and intensities. Since it operates in a Pulse-by-Pulse Modulation mode at 7.5 Hz, the computer controlled functions of time and magnetic field, and the 64 timing triggers of the beam control system take on unique values for each of four PPM users. Beams of {sup 197}Au{sup +33} ions and protons have been accelerated in the same PPM cycle.

  11. Active Nozzle Control and Integrated Design Optimization of a Beam Subject to Fluid-Dynamic Forces

    Science.gov (United States)

    Borglund, D.

    1999-02-01

    Active nozzle control is used to improve the stability of a beam subject to forces induced by fluid flow through attached pipes. The control system has a significant effect on the structural stability, making both flutter and divergence type of instabilities possible. The stability analysis is carried out using a state-variable approach based on a finite element formulation of the structural dynamics. The simultaneous design of the control system and the beam shape minimizing structural mass is performed using numerical optimization. The inclusion of the control system in the optimization gives a considerable reduction of the structural mass but results in an optimal design which is very sensitive to imperfections. Using a simple model of the control system uncertainties, a more robust design is obtained by solving a modified optimization problem. Throughout the study, the theoretical findings are verified by experiments.

  12. An embeddable optical strain gauge based on a buckled beam

    Science.gov (United States)

    Du, Yang; Chen, Yizheng; Zhu, Chen; Zhuang, Yiyang; Huang, Jie

    2017-11-01

    We report, for the first time, a low cost, compact, and novel mechanically designed extrinsic Fabry-Perot interferometer (EFPI)-based optical fiber sensor with a strain amplification mechanism for strain measurement. The fundamental design principle includes a buckled beam with a coated gold layer, mounted on two grips. A Fabry-Perot cavity is produced between the buckled beam and the endface of a single mode fiber (SMF). A ceramic ferrule is applied for supporting and orienting the SMF. The principal sensor elements are packaged and protected by two designed metal shells. The midpoint of the buckled beam will experience a deflection vertically when the beam is subjected to a horizontally/axially compressive displacement. It has been found that the vertical deflection of the beam at midpoint can be 6-17 times larger than the horizontal/axial displacement, which forms the basis of a strain amplification mechanism. The user-configurable buckling beam geometry-based strain amplification mechanism enables the strain sensor to achieve a wide range of strain measurement sensitivities. The designed EFPI was used to monitor shrinkage of a square brick of mortar. The strain was measured during the drying/curing stage. We envision that it could be a good strain sensor to be embedded in civil materials/structures under a harsh environment for a prolonged period of time.

  13. Progress in computer-assisted diagnosis and control of neutral beam lines

    International Nuclear Information System (INIS)

    Theil, E.; Elischer, V.; Fiddler, J.; Jacobs, N.J.D.; Jacobson, V.; Lawhorn, R.; Uber, D.; Wilner, D.

    1980-09-01

    This paper discusses the principles that have guided the development of a computerized diagnostic and control system for both the Neutral Beam Systems Test Facility at Lawrence Berkeley Laboratory and the Doublet III neutral beams at the General Atomic Company. The emphasis is not on the particular details of the implementation, but on general considerations which have influenced the design criteria for the system. Foremost among these are the requirements of an appropriate human interface to the system, and effective use of a relational data base. Examples are used to illustrate how these principles are carried out in practice. A systems view of diagnostic programs is suggested in the light of our experience

  14. Application of diamond based beam loss monitors at LHC

    International Nuclear Information System (INIS)

    Hempel, Maria

    2013-04-01

    collimators. Ionization chambers have a time resolution of 40 s that is a half LHC turn and in case of a large beam loss, they request a beam dump. Another type of beam loss monitors are diamond sensors because of a time resolution of about one nanosecond and high radiation hardness. One diamond detector system is located in the cleaning region of the LHC and is able to detect various types of beam losses. Another diamond detector system (BCM1F) is installed inside the CMS detector to protect the CMS from adverse beam conditions. BCM1F monitors also the luminosity during collisions and delivers important beam parameters. Additional condition monitors, based on the BCM1F system, are located next to CMS, near to LHCb and ALICE to measure large beam losses in the LHC ring. The process of a beam loss due to dust particles is explained, and additional simulations were done to understand these process in more detail. The result of the simulation are also given. Beam loss data recorded by the diamond sensors in the cleaning region and the BCM1F diamonds are presented.

  15. Application of diamond based beam loss monitors at LHC

    Energy Technology Data Exchange (ETDEWEB)

    Hempel, Maria

    2013-04-15

    the LHC, especially near each quadrupole and next to collimators. Ionization chambers have a time resolution of 40 s that is a half LHC turn and in case of a large beam loss, they request a beam dump. Another type of beam loss monitors are diamond sensors because of a time resolution of about one nanosecond and high radiation hardness. One diamond detector system is located in the cleaning region of the LHC and is able to detect various types of beam losses. Another diamond detector system (BCM1F) is installed inside the CMS detector to protect the CMS from adverse beam conditions. BCM1F monitors also the luminosity during collisions and delivers important beam parameters. Additional condition monitors, based on the BCM1F system, are located next to CMS, near to LHCb and ALICE to measure large beam losses in the LHC ring. The process of a beam loss due to dust particles is explained, and additional simulations were done to understand these process in more detail. The result of the simulation are also given. Beam loss data recorded by the diamond sensors in the cleaning region and the BCM1F diamonds are presented.

  16. Design of a neutrino source based on beta beams

    Directory of Open Access Journals (Sweden)

    E. Wildner

    2014-07-01

    Full Text Available “Beta beams” produce collimated pure electron (antineutrino beams by accelerating beta active ions to high energies and having them decay in a racetrack shaped storage ring of 7 km circumference, the decay ring. EUROnu beta beams are based on CERN infrastructures and existing machines. Using existing machines may be an advantage for the cost evaluation, but will also constrain the physics performance. The isotope pair of choice for the beta beam is ^{6}He and ^{18}Ne. However, before the EUROnu studies one of the required isotopes, ^{18}Ne, could not be produced in rates that satisfy the needs for physics of the beta beam. Therefore, studies of alternative beta emitters, ^{8}Li and ^{8}B, with properties interesting for a beta beam have been proposed and have been studied within EUROnu. These alternative isotopes could be produced by using a small storage ring, in which the beam traverses a target, creating the ^{8}Li and ^{8}B isotopes. This production ring, the injection linac and the target system have been evaluated. Measurements of the cross section of the reactions to produce the beta beam isotopes show interesting results. A device to collect the produced isotopes from the target has been developed and tested. However, the yields of ^{8}Li and ^{8}B, using the production ring for production of ^{8}Li and ^{8}B, is not yet, according to simulations, giving the rates of isotopes that would be needed. Therefore, a new method of producing the ^{18}Ne isotope has been developed and tested giving good production rates. A 60 GHz ECRIS prototype, the first in the world, was developed and tested for ion production with contributions from EUROnu. The decay ring lattices for the ^{8}Li and ^{8}B have been developed and the lattice for ^{6}He and ^{18}Ne has been optimized to ensure the high intensity ion beam stability.

  17. Modified source of a fast neutral atom beam with a controlled energy

    International Nuclear Information System (INIS)

    Gostev, V.A.; Elakhovskij, D.V.; Khakhaev, A.D.

    1980-01-01

    A source of a metastable helium atom beam with a controlled energy based on a phenomenon of resonant ion neutralization on the surface of a solid body is described. The neutral particle energy control is carried out by changing ion velocities before their transformation into metastable atoms. The results of experiments with a modified construction of atomic beam source are stated. These experiments were conducted to find the possibilities to control velocities of atoms in a flow as well as to elucidate the peculiarities of operation of a collimator-converter of this construction. Dependences of a halfwidth of the ion velocity distribution function on the ion source parameters have been investigated. The possibility for particle energy control in a collimated flow of fast neutral. atoms has been experimentally shown, it is also shown that a mean value of atom energy in a beam coincides with a value of mean energy of ions from which atoms are produced by the resonant neutralization method; the construction of the source provides the possibility to realize the method of ''overtaking beams'' for neutral atoms and as a result of this to give a possibility for studying atom-atom collisions in a wide energy range at relatively high densities of flows

  18. Control of laser-accelerated proton beams by modifying the target density with ASE

    Energy Technology Data Exchange (ETDEWEB)

    Yogo, A.; Kiriyama, H.; Mori, M.; Esirkepov, T.Zh.; Ogura, K.; Sagisaka, A.; Orimo, S.; Nishiuchi, M.; Pirozhkov, A.S.; Nakai, Y.; Shimomura, T.; Tanoue, M.; Akutsu, A.; Okada, H.; Motomura, T.; Kondo, S.; Kanazawa, S.; Bulanov, S.V.; Bolton, P.R.; Daido, H. [Photo-Medical Research Center and Advanced Photon Research Center, JAEA, Kyoto (Japan); Nagatomo, H. [Osaka Univ., Institute of Laser Engineering (Japan)

    2009-11-15

    We demonstrate laser-ion acceleration from a near-critical density plasma, using amplified spontaneous emission (ASE) to convert a solid foil target into a lower-density target. In order to investigate the target density dependence of the laser-ion acceleration, two cases were investigated for which the ASE intensity differed by three orders of magnitude. In the low contrast case the beam centre for higher energy protons is shifted closer to the laser-propagation direction of 45 degrees, while the centre of lower-energy beam remains near the target normal direction. We show that a near-critical density plasma can be used to control proton beam direction based on its energy. (authors)

  19. Fast control and data acquisition in the neutral beam test facility

    Energy Technology Data Exchange (ETDEWEB)

    Luchetta, A., E-mail: adriano.luchetta@igi.cnr.it; Manduchi, G.; Taliercio, C.

    2014-05-15

    Highlights: • The paper describes the fast control and data acquisition in the ITER neutral beam test facility. • The usage of real time control in ion beam generation and extraction is proposed. • Real time management of breakdowns is described. • The implementation of event-driven data acquisition is reported. - Abstract: Fast control and data acquisition are required in the ion source test bed of the ITER neutral beam test facility, referred to as SPIDER. Fast control will drive the operation of the power supply systems with particular reference to special asynchronous events, such as the breakdowns. These are short-circuits among grids or between grids and vessel that can occur repeatedly during beam operation. They are normal events and, as such, they will be managed by the fast control system. Cycle time associated to such fast control is down to hundreds of microseconds. Fast data acquisition is required when breakdowns occur. Event-driven data acquisition is triggered in real time by fast control at the occurrence of each breakdown. Pre- and post-event samples are acquired, allowing capturing information on transient phenomena in a whole time-window centered on the event. Sampling rate of event-driven data acquisition is up to 5 MS/s. Fast data acquisition may also be independent of breakdowns as in the case of the cavity ring-down spectroscopy where data chunks are acquired at 100 MS/s in bursts of 1.5 ms every 100 ms and are processed in real time to produce derived measurements. The paper after the description of the SPIDER fast control and data acquisition application will report the system design based on commercially available hardware and the MARTe and MDSplus software frameworks. The results obtained by running a full prototype of the fast control and data acquisition system are also reported and discussed. They demonstrate that all SPIDER fast control and data acquisition requirements can be met in the prototype solution.

  20. Experimental demonstration of dielectric structure based two beam acceleration

    International Nuclear Information System (INIS)

    Gai, W.; Conde, M. E.; Konecny, R.; Power, J. G.; Schoessow, P.; Sun, X.; Zou, P.

    2000-01-01

    We report on the experimental results of the dielectric based two beam accelerator (step-up transformer). By using a single high charge beam, we have generated and extracted a high power RF pulse from a 7.8 GHz primary dielectric structure and then subsequently transferred to a second accelerating structure with higher dielectric constant and smaller transverse dimensions. We have measured the energy change of a second (witness) beam passing through the acceleration stage. The measured gradient is >4 times the deceleration gradient. The detailed experiment of set-up and results of the measurements are dimmed. Future plans for the development of a 100 MeV demonstration accelerator based on this technique is presented

  1. Computer control of the beam transport system of the Chalk River electron test accelerator

    International Nuclear Information System (INIS)

    McMichael, G.E.; Kidner, S.H.; Fraser, J.S.

    1977-05-01

    The beam transport system of the Chalk River Electron Test Accelerator comprises steering coils and solenoidal focusing magnets driven by voltage-programmed, current-regulated power supplies. This report describes the beam transport and beam diagnostics systems presently in use. The computer controls all beam transport magnets from a single, allocatable control knob. The system is currently being expanded to two knobs and two readouts. (author)

  2. High energy beam line based on bent crystal

    International Nuclear Information System (INIS)

    Biryukov, V.M.; Chesnokov, Yu.A.; Greth, V.N.; Ivanov, A.A.; Kotov, V.I.; Selesnev, V.S.; Tarakanov, M.V.; Terekhov, V.I.; Tsarik, S.V.

    1995-01-01

    A peculiarities of the beam bent with crystals is the independence of the crystal deflector strength Θ=L D /R c ∼0.5 rad of the particle energy (L D is the dechanneling length, R c is the critical radius). The possibility of abrupt bending with crystal of a beam fraction at a large angle allows one to make over a short base a non-traditional beam line to carry out physical experiments. At IHEP, a 150 mrad bent crystal was used to create a test area, to work in parallel with other set-ups consuming practically no power. A 100 mm long Si crystal, placed in the halo of the intense extracted 70 GeV/c beam, extracts along the ∼20 m base 10 6 protons/sec beyond the 2-meter iron-concrete shield. The beam high quality (low emittance and high stability) allows one to carry out the program of the studies of channeling and testing the microstrip detectors. 2 refs.; 2 figs

  3. Application of ion beams for polymeric carbon based biomaterials

    Science.gov (United States)

    Evelyn, A. L.

    2001-07-01

    Ion beams have been shown to be quite suitable for the modification and analysis of carbon based biomaterials. Glassy polymeric carbon (GPC), made from cured phenolic resins, has a high chemical inertness that makes it useful as a biomaterial in medicine for drug delivery systems and for the manufacture of heart valves and other prosthetic devices. Low and high-energy ion beams have been used, with both partially and fully cured phenolic resins, to enhance biological cell/tissue growth on, and to increase tissue adhesion to GPC surfaces. Samples bombarded with energetic ion beams in the keV to MeV range exhibited increased surface roughness, measured using optical microscopy and atomic force microscopy. Ion beams were also used to perform nuclear reaction analyses of GPC encapsulated drugs for use in internal drug delivery systems. The results from the high energy bombardment were more dramatic and are shown in this paper. The interaction of energetic ions has demonstrated the useful application of ion beams to enhance the properties of carbon-based biomaterials.

  4. A unified analysis of FBP-based algorithms in helical cone-beam and circular cone- and fan-beam scans

    International Nuclear Information System (INIS)

    Pan Xiaochuan; Xia Dan; Zou Yu; Yu Lifeng

    2004-01-01

    A circular scanning trajectory is and will likely remain a popular choice of trajectory in computed tomography (CT) imaging because it is easy to implement and control. Filtered-backprojection (FBP)-based algorithms have been developed previously for approximate and exact reconstruction of the entire image or a region of interest within the image in circular cone-beam and fan-beam cases. Recently, we have developed a 3D FBP-based algorithm for image reconstruction on PI-line segments in a helical cone-beam scan. In this work, we demonstrated that the 3D FBP-based algorithm indeed provided a rather general formulation for image reconstruction from divergent projections (such as cone-beam and fan-beam projections). On the basis of this formulation we derived new approximate or exact algorithms for image reconstruction in circular cone-beam or fan-beam scans, which can be interpreted as special cases of the helical scan. Existing algorithms corresponding to the derived algorithms were identified. We also performed a preliminary numerical study to verify our theoretical results in each of the cases. The results in the work can readily be generalized to other non-circular trajectories

  5. Plasma based Ar+ beam assisted poly(dimethylsiloxane) surface modification

    International Nuclear Information System (INIS)

    Vladkova, T.G.; Keranov, I.L.; Dineff, P.D.; Youroukov, S.Y.; Avramova, I.A.; Krasteva, N.; Altankov, G.P.

    2005-01-01

    Plasma based Ar + beam performed in RF (13.56 MHz) low-pressure (200 mTorr) glow discharge (at 100 W, 1200 W and 2500 W) with a serial capacitance was employed for surface modification of poly(dimethylsiloxane) (PDMS) aimed at improvement of its interactions with living cells. The presence of a serial capacitance ensures arise of an ion-flow inside the plasma volume directed toward the treated sample and the vary of the discharge power ensures varied density of the ion-flow. XPS analysis was performed to study the changes in the surface chemical composition of the modified samples and the corresponding changes in the surface energy were monitored by contact angle measurements. We found that plasma based Ar + beam transforms the initially hydrophobic PDMS surface into a hydrophilic one mainly due to a raising of the polar component of the surface tension, this effect being most probably due to an enrichment of the modified surface layer with permanent dipoles of a [SiO x ]-based network and elimination of the original methyl groups. The initial adhesion of human fibroblast cells was studied on the described above plasma based Ar + beam modified and acrylic acid (AA) grafted or not fibronectin (FN) pre-coated or bare surfaces. The cell response seems to be related with the peculiar structure and wettability of the modified PDMS surface layer after plasma based Ar + beam treatment followed or not by AA grafting

  6. Synchrotron Radiation Beam Line of Piezoelectric Monochromator Control

    International Nuclear Information System (INIS)

    Ye Shengan; LIU Ping; Zheng Lifang

    2009-01-01

    It describes a Piezo Amplifier and Servo-controller module applied in the LN2-cooled Monochromator control system. The application of RS232 communication based on EPICS software environment and its software are implemented. (authors)

  7. National negative-ion-based neutral-beam development plan

    International Nuclear Information System (INIS)

    Cooper, W.S.; Pyle, R.V.

    1983-08-01

    The plan covers facilities required, program milestones, and decision points. It includes identification of applications, experiments, theoretical research areas, development of specific technologies and reactor development and demonstration facilities required to bring about the successful application of negative-ion-based neutral beams. Particular emphasis is placed on those activities leading to use on existing plasma confinement experiments or their upgrades

  8. Mimicking the cochlear amplifier in a cantilever beam using nonlinear velocity feedback control

    International Nuclear Information System (INIS)

    Joyce, Bryan S; Tarazaga, Pablo A

    2014-01-01

    The mammalian cochlea exhibits a nonlinear amplification which allows mammals to detect a large range of sound pressure levels while maintaining high frequency sensitivity. This work seeks to mimic the cochlea’s nonlinear amplification in a mechanical system. A nonlinear, velocity-based feedback control law is applied to a cantilever beam with piezoelectric actuators. The control law reduces the linear viscous damping of the system while introducing a cubic damping term. The result is a system which is positioned close to a Hopf bifurcation. Modelling and experimental results show that the beam with this control law undergoes a one-third amplitude scaling near the resonance frequency and an amplitude-dependent bandwidth. Both behaviors are characteristic of data obtained from the mammalian cochlea. This work could provide insight on the biological cochlea while producing bio-inspired sensors with a large dynamic range and sharp frequency sensitivity. (papers)

  9. Mimicking the cochlear amplifier in a cantilever beam using nonlinear velocity feedback control

    Science.gov (United States)

    Joyce, Bryan S.; Tarazaga, Pablo A.

    2014-07-01

    The mammalian cochlea exhibits a nonlinear amplification which allows mammals to detect a large range of sound pressure levels while maintaining high frequency sensitivity. This work seeks to mimic the cochlea’s nonlinear amplification in a mechanical system. A nonlinear, velocity-based feedback control law is applied to a cantilever beam with piezoelectric actuators. The control law reduces the linear viscous damping of the system while introducing a cubic damping term. The result is a system which is positioned close to a Hopf bifurcation. Modelling and experimental results show that the beam with this control law undergoes a one-third amplitude scaling near the resonance frequency and an amplitude-dependent bandwidth. Both behaviors are characteristic of data obtained from the mammalian cochlea. This work could provide insight on the biological cochlea while producing bio-inspired sensors with a large dynamic range and sharp frequency sensitivity.

  10. Update on MEMS-based scanned beam imager

    Science.gov (United States)

    James, Richard; Gibson, Greg; Metting, Frank; Davis, Wyatt; Drabe, Christian

    2007-01-01

    In 2004, Microvision presented "Scanned Beam Medical Imager" as an introduction to our MEMS-based, full color scanned beam imaging system. This presentation will provide an update of the technological advancements since this initial work from 2004. This recent work includes the development of functional prototypes that are much smaller than previous prototypes using a design architecture that is easily scalable. Performance has been significantly improved by increasing the optical field of views and video refresh rate. Real-time image processing capabilities have been developed to enhance the image quality and functionality over a wide range of operating conditions. Actual images of various objects will be presented.

  11. Network secure communications based on beam halo-chaos

    International Nuclear Information System (INIS)

    Liu Qiang; Fang Jinqing; Li Yong

    2010-01-01

    Based on beam halo-chaos synchronization in the beam transport network (line)with small-world effect, using three synchronization methods:the driver-response synchronization, small-world topology coupling synchronization and multi-local small-world topology coupling synchronization, three kinds of secure communication projects were designed respectively, and were studied numerically by the Simulink tool of the Matlab software. Numerical experimental results demonstrate that encryption and decryption of the original signal are realized successfully. It provides effective theoretical foundation and reference for the next engineering design and network experiment. (authors)

  12. Electron Beam Diagnostic Based on a Short Seeded FEL

    CERN Document Server

    Graves, W; Kaertner, Franz X; Zwart, T

    2005-01-01

    The optical properties of an FEL amplifier are sensitively dependent on the electron beam current profile, energy spread, and transverse emittance. In this paper we consider using a short FEL amplifier operating on a low harmonic of a visible-IR input seed as a mildly destructive electron beam diagnostic able to measure these properties for sub-ps time slices. The optical methods are described as well as a planned implementation of the device for the FERMI@Elettra XUV FEL under construction at Sincrotrone Trieste, including its fiber-based seed laser closely coupled with the facility timing system, undulator parameters, and requirements on the electron and FEL pulses. This diagnostic is conveniently integrated with a "laser heater" designed to increase the very low electron beam energy spread produced by a photoinjector in order to avoid space charge and coherent synchrotron radiation instabilities.

  13. Damping of Torsional Beam Vibrations by Control of Warping Displacement

    DEFF Research Database (Denmark)

    Høgsberg, Jan Becker; Hoffmeyer, David; Ejlersen, Christian

    2016-01-01

    Supplemental damping of torsional beam vibrations is considered by viscous bimoments acting on the axial warping displacement at the beam supports. The concept is illustrated by solving the governing eigenvalue problem for various support configurations with the applied bimoments represented...

  14. Status of the control and beam diagnostic systems of the CRYRING project

    International Nuclear Information System (INIS)

    Starker, J.; Engstroem, M.

    1992-01-01

    CRYRING is a facility for research in atomic, molecular and nuclear physics. It uses a cryogenic electron beam ion source, CRYSIS, together with an RFQ linear accelerator as injector into a synchrotron/storage ring for very highly charged, heavy ions. The first circulating beam was achieved in december 1990. The status of the systems for control and beam diagnostics are described. (author)

  15. Controlling multibunch beam breakup in TeV linear colliders

    International Nuclear Information System (INIS)

    Thompson, K.A.; Ruth, R.D.

    1989-01-01

    To obtain luminosities near 10 34 cm/sup /minus/2/sec/sup /minus/1/ in a TeV linear collider, it will probably be essential to accelerate many bunches per RF fill in order to increase the energy transfer efficiency. In this paper we study the transverse dynamics of multiple bunches in a linac, and we examine the effects of several methods of controlling the beam blow-up that would otherwise be induced by transverse dipole wake fields. The methods we study are: damping the transverse modes, adjusting the frequency of the dominant transverse modes so that bunches may be placed near zero-crossings of the transverse wake, and bunch-to-bunch variation of the transverse focusing. We study the utility of these cures in the main linacs of an example of a TeV collider. 16 refs., 4 figs., 2 tabs

  16. Arbitrary control of the polarization and intensity profiles of diffraction-attenuation-resistant beams along their propagation direction

    OpenAIRE

    Corato-Zanarella, Mateus; Dorrah, Ahmed H.; Zamboni-Rached, Michel; Mojahedi, Mo

    2017-01-01

    We report on the theory and experimental generation of a class of diffraction-attenuation-resistant beams with state of polarization (SoP) and intensity that can be controlled on demand along the propagation direction. This is achieved by a suitable superposition of Bessel beams, whose parameters are systematically chosen based on closed-form analytic expressions provided by the Frozen Waves (FWs) method. Using an amplitude-only spatial light modulator, we experimentally demonstrate three sce...

  17. Arduino based laser control

    OpenAIRE

    Bernal Muñoz, Ferran

    2015-01-01

    ARDUINO is a vey usefull platform for prototypes. In this project ARDUINO will be used for controling a Semiconductor Tuneable Laser. [ANGLÈS] Diode laser for communications control based on an Arduino board. Temperature control implementation. Software and hardware protection for the laser implementation. [CASTELLÀ] Control de un láser de comunicaciones ópticas desde el ordenador utilizando una placa Arduino. Implementación de un control de temperatura y protección software y hardware ...

  18. Beam control and diagnostic functions in the NIF transport spatial filter

    International Nuclear Information System (INIS)

    Holdener, F.R.; Ables, E.; Bliss, E.S.

    1996-10-01

    Beam control and diagnostic systems are required to align the National Ignition Facility (NIF) laser prior to a shot as well as to provide diagnostics on 192 beam lines at shot time. A design that allows each beam's large spatial filter lenses to also serve as objective lenses for beam control and diagnostic sensor packages helps to accomplish the task at a reasonable cost. However, this approach also causes a high concentration of small optics near the pinhole plane of the transport spatial filter (TSF) at the output of each beam. This paper describes the optomechanical design in and near the central vacuum vessel of the TSF

  19. Development of a nuclear data base for relativistic ion beams

    International Nuclear Information System (INIS)

    Townsend, L.W.; Wong, M.; Schimmerling, W.; Wilson, J.W.

    1987-01-01

    The primary limitation on the development of heavy ion beam transport methods is the lack of an accurate nuclear data base. Because of the large number of ion/target combinations, the complexity of the reaction products, and the broad range of energies required, it is unlikely that the data base will ever be compiled from experiments alone. For the last 15 years, relativistic heavy-ion accelerators have been available, but the experimental data base remains inadequate. However, theoretical models of heavy-ion reactions are being derived to provide cross section data for beam transport problems. A concurrent experimental program to provide sufficient experimental data to validate the model is also in progress. Model development and experimental results for model validation are discussed. The need for additional nuclear fragmentation data is identified

  20. Implementation of Accelerated Beam-Specific Matched-Filter-Based Optical Alignment

    Energy Technology Data Exchange (ETDEWEB)

    Awwal, A S; Rice, K L; Taha, T M

    2009-01-29

    Accurate automated alignment of laser beams in the National Ignition Facility (NIF) is essential for achieving extreme temperature and pressure required for inertial confinement fusion. The alignment achieved by the integrated control systems relies on algorithms processing video images to determine the position of the laser beam images in real-time. Alignment images that exhibit wide variations in beam quality require a matched-filter algorithm for position detection. One challenge in designing a matched-filter based algorithm is to construct a filter template that is resilient to variations in imaging conditions while guaranteeing accurate position determination. A second challenge is to process the image as fast as possible. This paper describes the development of a new analytical template that captures key recurring features present in the beam image to accurately estimate the beam position under good image quality conditions. Depending on the features present in a particular beam, the analytical template allows us to create a highly tailored template containing only those selected features. The second objective is achieved by exploiting the parallelism inherent in the algorithm to accelerate processing using parallel hardware that provides significant performance improvement over conventional processors. In particular, a Xilinx Virtex II Pro FPGA hardware implementation processing 32 templates provided a speed increase of about 253 times over an optimized software implementation running on a 2.0 GHz AMD Opteron core.

  1. Control of beam halo-chaos using neural network self-adaptation method

    International Nuclear Information System (INIS)

    Fang Jinqing; Huang Guoxian; Luo Xiaoshu

    2004-11-01

    Taking the advantages of neural network control method for nonlinear complex systems, control of beam halo-chaos in the periodic focusing channels (network) of high intensity accelerators is studied by feed-forward back-propagating neural network self-adaptation method. The envelope radius of high-intensity proton beam is reached to the matching beam radius by suitably selecting the control structure of neural network and the linear feedback coefficient, adjusted the right-coefficient of neural network. The beam halo-chaos is obviously suppressed and shaking size is much largely reduced after the neural network self-adaptation control is applied. (authors)

  2. Active Vibration damping of Smart composite beams based on system identification technique

    Science.gov (United States)

    Bendine, Kouider; Satla, Zouaoui; Boukhoulda, Farouk Benallel; Nouari, Mohammed

    2018-03-01

    In the present paper, the active vibration control of a composite beam using piezoelectric actuator is investigated. The space state equation is determined using system identification technique based on the structure input output response provided by ANSYS APDL finite element package. The Linear Quadratic (LQG) control law is designed and integrated into ANSYS APDL to perform closed loop simulations. Numerical examples for different types of excitation loads are presented to test the efficiency and the accuracy of the proposed model.

  3. Mitigation of beam fluctuation due to atmospheric turbulence and prediction of control quality using intelligent decision-making tools.

    Science.gov (United States)

    Raj, A Arockia Bazil; Selvi, J Arputha Vijaya; Kumar, D; Sivakumaran, N

    2014-06-10

    In free-space optical link (FSOL), atmospheric turbulence causes fluctuations in both intensity and phase of the received beam and impairing link performance. The beam motion is one of the main causes for major power loss. This paper presents an investigation on the performance of two types of controller designed for aiming a laser beam to be at a particular spot under dynamic disturbances. The multiple experiment observability nonlinear input-output data mapping is used as the principal components for controllers design. The first design is based on the Taguchi method while the second is artificial neural network method. These controllers process the beam location information from a static linear map of 2D plane: optoelectronic position detector, as observer, and then generate the necessary outputs to steer the beam with a microelectromechanical mirror: fast steering mirror. The beam centroid is computed using monopulse algorithm. Evidence of suitability and effectiveness of the proposed controllers are comprehensively assessed and quantitatively measured in terms of coefficient of correlation, correction speed, control exactness, centroid displacement, and stability of the receiver signal through the experimental results from the FSO link setup established for the horizontal range of 0.5 km at an altitude of 15.25 m. The test field type is open flat terrain, grass, and few isolated obstacles.

  4. Vibration Control of Sandwich Beams Using Electro-Rheological Fluids

    Science.gov (United States)

    Srikantha Phani, A.; Venkatraman, K.

    2003-09-01

    Electro-rheological (ER) fluids are a class of smart materials exhibiting significant reversible changes in their rheological and hence mechanical properties under the influence of an applied electric field. Efforts are in progress to embed ER fluids in various structural elements to mitigate vibration problems. The present work is an experimental investigation of the behaviour of a sandwich beam with ER fluid acting as the core material. A starch-silicone-oil-based ER fluid is used in the present study. Significant improvements in the damping properties are achieved in experiments and the damping contributions by viscous and non-viscous forces are estimated by force-state mapping (FSM) technique. With the increase in electric field across the ER fluid from 0 to 2 kV, an increase of 25-50% in equivalent viscous damping is observed. It is observed that as concentration of starch is increased, the ER effect grows stronger but eventually is overcome by applied stresses.

  5. Damage identification in beams by a response surface based technique

    Directory of Open Access Journals (Sweden)

    Teidj S.

    2014-01-01

    Full Text Available In this work, identification of damage in uniform homogeneous metallic beams was considered through the propagation of non dispersive elastic torsional waves. The proposed damage detection procedure consisted of the following sequence. Giving a localized torque excitation, having the form of a short half-sine pulse, the first step was calculating the transient solution of the resulting torsional wave. This torque could be generated in practice by means of asymmetric laser irradiation of the beam surface. Then, a localized defect assumed to be characterized by an abrupt reduction of beam section area with a given height and extent was placed at a known location of the beam. Next, the response in terms of transverse section rotation rate was obtained for a point situated afterwards the defect, where the sensor was positioned. This last could utilize in practice the concept of laser vibrometry. A parametric study has been conducted after that by using a full factorial design of experiments table and numerical simulations based on a finite difference characteristic scheme. This has enabled the derivation of a response surface model that was shown to represent adequately the response of the system in terms of the following factors: defect extent and severity. The final step was performing the inverse problem solution in order to identify the defect characteristics by using measurement.

  6. Ultra-low-frequency vertical vibration isolator based on a two-stage beam structure for absolute gravimetry

    Science.gov (United States)

    Wang, G.; Wu, K.; Hu, H.; Li, G.; Wang, L. J.

    2016-10-01

    To reduce seismic and environmental vibration noise, ultra-low-frequency vertical vibration isolation systems play an important role in absolute gravimetry. For this purpose, an isolator based on a two-stage beam structure is proposed and demonstrated. The isolator has a simpler and more robust structure than the present ultra-low-frequency vertical active vibration isolators. In the system, two beams are connected to a frame using flexural pivots. The upper beam is suspended from the frame with a normal hex spring and the lower beam is suspended from the upper one using a zero-length spring. The pivot of the upper beam is not vertically above the pivot of the lower beam. With this special design, the attachment points of the zero-length spring to the beams can be moved to adjust the effective stiffness. A photoelectric detector is used to detect the angle between the two beams, and a voice coil actuator attached to the upper beam is controlled by a feedback circuit to keep the angle at a fixed value. The system can achieve a natural period of 100 s by carefully moving the attachment points of the zero-length spring to the beams and tuning the feedback parameters. The system has been used as an inertial reference in the T-1 absolute gravimeter. The experiment results demonstrate that the system has significant vibration isolation performance that holds promise in applications such as absolute gravimeters.

  7. Electron Beam Energy Compensation by Controlling RF Pulse Shape

    CERN Document Server

    Kii, T; Kusukame, K; Masuda, K; Nakai, Y; Ohgaki, H; Yamazaki, T; Yoshikawa, K; Zen, H

    2005-01-01

    We have studied on improvement of electron beam macropulse properties from a thermionic RF gun. Though a thermionic RF gun has many salient features, there is a serious problem that back-bombardment effect worsens quality of the beam. To reduce beam energy degradation by this effect, we tried to feed non-flat RF power into the gun. As a result, we successfully obtained about 1.5 times longer macropulse and two times larger total charge per macropulse. On the other hand, we calculated transient evolution of RF power considering non-constant beam loading. The beam loading is evaluated from time evolution of cathode temperature, by use of one dimensional heat conduction model and electron trajectories' calculations by a particle simulation code. Then we found good agreement between the experimental and calculation results. Furthermore, with the same way, we studied the electron beam output dependence on the cathode radius.

  8. Evaluation of uncertainty in experimental active buckling control of a slender beam-column with disturbance forces using Weibull analysis

    Science.gov (United States)

    Enss, Georg C.; Platz, Roland

    2016-10-01

    Buckling of slender load-bearing beam-columns is a crucial failure scenario in light-weight structures as it may result in the collapse of the entire structure. If axial load and load capacity are unknown, stability becomes uncertain. To compensate this uncertainty, the authors successfully developed and evaluated an approach for active buckling control for a slender beam-column, clamped at the base and pinned at the upper end. Active lateral forces are applied with two piezoelectric stack actuators in opposing directions near the beam-column' clamped base to prevent buckling. A Linear Quadratic Regulator is designed and implemented on the experimental demonstrator and statistical tests are conducted to prove effectivity of the active approach. The load capacity of the beam-column could be increased by 40% and scatter of buckling occurrences for increasing axial loads is reduced. Weibull analysis is used to evaluate the increase of the load capacity and its related uncertainty compensation.

  9. Distributed CAN-bus Based Beam Diagnostic System for Pulse Race-Track Microtron

    Science.gov (United States)

    Chepurnov, Alexander

    Very compact 70 MeV pulse race-track microtron is under construction now. To acquire outputs of beam-current transformers on every orbit and pulses of high voltage and RF field a distributed multi-channel beam diagnostic system was developed. Each acquisition controller consists of four fast differential amplifiers and one DSP-based micro-controller with on-chip ADC and CAN-bus controller. Each amplifier is coupled with beam-current transformer and has bandwidth of up to 150MHz and gain of up to 10. One of four channels is acquired during a measurement cycle. Another channel could be selected between two following pulses. All the controllers are connected via optically coupled CAN-bus with a host diskless PC running under Linux with the RTLinux extension. Dedicated software of the system consists of low level acquisition software for DSP, network software for controllers and host PC, application software for PC to present date for operator and control system. Standard CAN application layers were considered but refused because of the closed character of the whole system and centralised synchronisation of the whole system. Dedicated software of the system consists from low level acquisition software for DSP, network software for controllers and host PC, application software for PC to present date for operator and control system. Standard CAN application layers were considered but refused because of closed character of the whole system and centralised synchronisation of the whole system.

  10. Adaptive Model Predictive Vibration Control of a Cantilever Beam with Real-Time Parameter Estimation

    Directory of Open Access Journals (Sweden)

    Gergely Takács

    2014-01-01

    Full Text Available This paper presents an adaptive-predictive vibration control system using extended Kalman filtering for the joint estimation of system states and model parameters. A fixed-free cantilever beam equipped with piezoceramic actuators serves as a test platform to validate the proposed control strategy. Deflection readings taken at the end of the beam have been used to reconstruct the position and velocity information for a second-order state-space model. In addition to the states, the dynamic system has been augmented by the unknown model parameters: stiffness, damping constant, and a voltage/force conversion constant, characterizing the actuating effect of the piezoceramic transducers. The states and parameters of this augmented system have been estimated in real time, using the hybrid extended Kalman filter. The estimated model parameters have been applied to define the continuous state-space model of the vibrating system, which in turn is discretized for the predictive controller. The model predictive control algorithm generates state predictions and dual-mode quadratic cost prediction matrices based on the updated discrete state-space models. The resulting cost function is then minimized using quadratic programming to find the sequence of optimal but constrained control inputs. The proposed active vibration control system is implemented and evaluated experimentally to investigate the viability of the control method.

  11. Modeling and control of plasma rotation for NSTX using neoclassical toroidal viscosity and neutral beam injection

    Energy Technology Data Exchange (ETDEWEB)

    Goumiri, I. R. [Princeton Univ., NJ (United States). Mechanical and Aerospace Dept.; Rowley, C. W. [Princeton Univ., NJ (United States). Mechanical and Aerospace Dept.; Sabbagh, S. A. [Columbia Univ., New York, NY (United States). Dept. of Applied Physics and Applied Mathematics; Gates, D. A. [Princeton Plasma Physics Lab. (PPPL), Princeton, NJ (United States); Gerhardt, S. P. [Princeton Plasma Physics Lab. (PPPL), Princeton, NJ (United States); Boyer, M. D. [Princeton Plasma Physics Lab. (PPPL), Princeton, NJ (United States); Andre, R. [Princeton Plasma Physics Lab. (PPPL), Princeton, NJ (United States); Kolemen, E. [Princeton Plasma Physics Lab. (PPPL), Princeton, NJ (United States); Taira, K. [Florida State Univ, Dept Mech Engn, Tallahassee, FL USA.

    2016-02-19

    A model-based feedback system is presented to control plasma rotation in a magnetically confined toroidal fusion device, to maintain plasma stability for long-pulse operation. This research uses experimental measurements from the National Spherical Torus Experiment (NSTX) and is aimed at controlling plasma rotation using two different types of actuation: momentum from injected neutral beams and neoclassical toroidal viscosity generated by three-dimensional applied magnetic fields. Based on the data-driven model obtained, a feedback controller is designed, and predictive simulations using the TRANSP plasma transport code show that the controller is able to attain desired plasma rotation profiles given practical constraints on the actuators and the available measurements of rotation.

  12. Construction and tests of an in-beam PET-like demonstrator for hadrontherapy beam ballistic control

    Energy Technology Data Exchange (ETDEWEB)

    Montarou, G., E-mail: montarou@clermont.in2p3.fr [Clermont University, Blaise Pascal University, CNRS/IN2P3, Laboratoire de Physique Corpusculaire, BP 10448, Clermont-Ferrand F-63000 (France); Bony, M.; Busato, E.; Chadelas, R. [Clermont University, Blaise Pascal University, CNRS/IN2P3, Laboratoire de Physique Corpusculaire, BP 10448, Clermont-Ferrand F-63000 (France); Donnarieix, D. [Centre Jean Perrin, Service de Physique Médicale, Clermont-Ferrand F-63000 (France); Force, P.; Guicheney, C.; Insa, C.; Lambert, D.; Lestand, L.; Magne, M.; Martin, F. [Clermont University, Blaise Pascal University, CNRS/IN2P3, Laboratoire de Physique Corpusculaire, BP 10448, Clermont-Ferrand F-63000 (France); Millardet, C. [Centre Jean Perrin, Service de Physique Médicale, Clermont-Ferrand F-63000 (France); Nivoix, M.; Podlyski, F.; Rozes, A. [Clermont University, Blaise Pascal University, CNRS/IN2P3, Laboratoire de Physique Corpusculaire, BP 10448, Clermont-Ferrand F-63000 (France)

    2017-02-11

    We present the first results obtained with a detector, called Large Area Pixelized Detector (LAPD), dedicated to the study the ballistic control of the beam delivered to the patient by in-beam and real time detection of secondary particles, emitted during its irradiation in the context of hadrontherapy. These particles are 511 keV γ from the annihilation of a positron issued from the β{sup +} emitters induced in the patient tissues along the beam path. The LAPD basic concepts are similar to a conventional PET camera. The 511 keV γ are detected and the reconstructed lines of response allow to measure the β{sup +} activity distribution. Nevertheless, when trying to use γ from positron annihilation for the ballistic control in hadrontherapy, the large prompt γ background should be taken into account and properly rejected. First reconstruction results, obtained with a phantom filled with a high intensity FDG source at the cancer research centre of Clermont-Ferrand are shown. We also report results of measurements performed at the Heidelberg Ion-Beam Therapy Centre with one third of the detector, using proton and carbon ion beams.

  13. An energy-based beam hardening model in tomography

    Energy Technology Data Exchange (ETDEWEB)

    Casteele, E van de; Dyck, D van; Sijbers, J; Raman, E [Vision Lab, Physics Departement, University of Antwerp (RUCA) (Belgium)

    2002-12-07

    As a consequence of the polychromatic x-ray source, used in micro-computer tomography ({mu}CT) and in medical CT, the attenuation is no longer a linear function of absorber thickness. If this nonlinear beam hardening effect is not compensated, the reconstructed images will be corrupted by cupping artefacts. In this paper, a bimodal energy model for the detected energy spectrum is presented, which can be used for reduction of artefacts caused by beam hardening in well-specified conditions. Based on the combination of the spectrum of the source and the detector efficiency, the assumption is made that there are two dominant energies which can describe the system. The validity of the proposed model is examined by fitting the model to the experimental datapoints obtained on a microtomograph for different materials and source voltages.

  14. Resolution and systematic limitations in beam based alignment

    Energy Technology Data Exchange (ETDEWEB)

    Tenenbaum, P.G.

    2000-03-15

    Beam based alignment of quadrupoles by variation of quadrupole strength is a widely-used technique in accelerators today. The authors describe the dominant systematic limitation of this technique, which arises from the change in the center position of the quadrupole as the strength is varied, and derive expressions for the resulting error. In addition, the authors derive an expression for the statistical resolution of such techniques in a periodic transport line, given knowledge of the line's transport matrices, the resolution of the beam position monitor system, and the details of the strength variation procedure. These results are applied to the Next Linear Collider main linear accelerator, an 11 kilometer accelerator containing 750 quadrupoles and 5,000 accelerator structures. The authors find that in principle a statistical resolution of 1 micron is easily achievable but the systematic error due to variation of the magnetic centers could be several times larger.

  15. High current nonlinear transmission line based electron beam driver

    Directory of Open Access Journals (Sweden)

    B. W. Hoff

    2017-10-01

    Full Text Available A gigawatt-class nonlinear transmission line based electron beam driver is experimentally demonstrated. Four experimental series, each with a different Marx bank charge voltage (15, 20, 25, and 30 kV, were completed. Within each experimental series, shots at peak frequencies ranging from 950 MHz to 1.45 GHz were performed. Peak amplitude modulations of the NLTL output voltage signal were found to range between 18% and 35% for the lowest frequency shots and between 5% and 20% for the highest frequency shots (higher modulation at higher Marx charge voltage. Peak amplitude modulations of the electron beam current were found to range between 10% and 20% for the lowest frequency shots and between 2% and 7% for the highest frequency shots (higher modulation at higher Marx charge voltage.

  16. Testing of a nuclear-reactor-based positron beam

    International Nuclear Information System (INIS)

    Van Veen, A.; Labohm, F.; Schut, H.; De Roode, J.; Heijenga, T.; Mijnarends, P.E.

    1997-01-01

    This paper describes the testing of a positron beam which is primarily based on copper activation near the core of a nuclear reactor and extraction of the positrons through a beam guide tube. An out-of-core test with a 22 Na source and an in-core test with the reactor at reduced power have been performed. Both tests indicated a high reflectivity of moderated positrons at the tungsten surfaces of the moderation discs which enhanced the expected yield. Secondary electrons generated in the source materials during the in-core test caused electrical field distortions in the electrode system of the system by charging of the insulators. At 100 kW reactor power during one hour, positrons were observed with an intensity of 4.4x10 4 e + s -1 of which 90% was due to positrons created by pair formation and 10% by copper activation

  17. An energy-based beam hardening model in tomography

    International Nuclear Information System (INIS)

    Casteele, E van de; Dyck, D van; Sijbers, J; Raman, E

    2002-01-01

    As a consequence of the polychromatic x-ray source, used in micro-computer tomography (μCT) and in medical CT, the attenuation is no longer a linear function of absorber thickness. If this nonlinear beam hardening effect is not compensated, the reconstructed images will be corrupted by cupping artefacts. In this paper, a bimodal energy model for the detected energy spectrum is presented, which can be used for reduction of artefacts caused by beam hardening in well-specified conditions. Based on the combination of the spectrum of the source and the detector efficiency, the assumption is made that there are two dominant energies which can describe the system. The validity of the proposed model is examined by fitting the model to the experimental datapoints obtained on a microtomograph for different materials and source voltages

  18. High current nonlinear transmission line based electron beam driver

    Science.gov (United States)

    Hoff, B. W.; French, D. M.; Simon, D. S.; Lepell, P. D.; Montoya, T.; Heidger, S. L.

    2017-10-01

    A gigawatt-class nonlinear transmission line based electron beam driver is experimentally demonstrated. Four experimental series, each with a different Marx bank charge voltage (15, 20, 25, and 30 kV), were completed. Within each experimental series, shots at peak frequencies ranging from 950 MHz to 1.45 GHz were performed. Peak amplitude modulations of the NLTL output voltage signal were found to range between 18% and 35% for the lowest frequency shots and between 5% and 20% for the highest frequency shots (higher modulation at higher Marx charge voltage). Peak amplitude modulations of the electron beam current were found to range between 10% and 20% for the lowest frequency shots and between 2% and 7% for the highest frequency shots (higher modulation at higher Marx charge voltage).

  19. Modeling FAMA ion beam diagnostics based on the Ptolemy II model

    Energy Technology Data Exchange (ETDEWEB)

    Balvanovic, R., E-mail: broman@vinca.rs [Laboratory of Physics, Vinca Institute of Nuclear Sciences, University of Belgrade, PO Box 522, 11001 Belgrade (Serbia); Belicev, P. [Laboratory of Physics, Vinca Institute of Nuclear Sciences, University of Belgrade, PO Box 522, 11001 Belgrade (Serbia); Radjenovic, B. [Institute of Physics, University of Belgrade, Pregrevica 118, 11080 Belgrade (Serbia)

    2012-10-21

    The previously developed model of ion beam transport control of the FAMA facility is further enhanced by equipping it with the model of ion beam diagnostics. The model of control, executing once, is adjusted so that it executes in iterative mode, where each iteration samples the input beam normally distributed over initial phase space and calculates a single trajectory through the facility beam lines. The model takes into account only the particles that manage to pass through all the beam line apertures, emulating in this way a Faraday cup and a beam profile meter. Generated are also beam phase space distributions and horizontal and vertical beam profiles at the end of the beam transport lines the FAMA facility consists of. By adding the model of ion beam diagnostics to the model of ion beam transport control, the process of determining optimal ion beam control parameters is eased and speeded up, and the understanding of influence of control parameters on the ion beam characteristics is improved.

  20. Performance of the HIMAC beam control system using multiple-energy synchrotron operation

    Science.gov (United States)

    Mizushima, K.; Furukawa, T.; Iwata, Y.; Hara, Y.; Saotome, N.; Saraya, Y.; Tansho, R.; Sato, S.; Fujimoto, T.; Shirai, T.; Noda, K.

    2017-09-01

    Multiple-energy synchrotron operation was developed to realize fast 3D scanning irradiation for carbon-ion radiotherapy. This type of operation can output various carbon-ion beams with different energies in a single synchrotron cycle. The beam control system used in this kind of operation was developed to quickly provide the beam energy and intensity required from the irradiation control system. The performance of the system was verified by experimental tests. The system could output beams of 197 different energies in 63 s. The beam intensity could be controlled for all the output beams without large ripples or overshooting. The experimental test of irradiation for prostate cancer treatment was also successfully performed, and the test results proved that our system can greatly reduce the irradiation time.

  1. From DNA Bases to Ultracold Atoms: Probing Ensembles Using Supersonic Beams

    Science.gov (United States)

    Smith, Valoris Reid

    This thesis discusses two ensembles, the study of which was dependent upon the controllable production of cold gas-phase samples using supersonic beams. The experiments on DNA bases and base clusters were carried out in Germany at the Max Born Institute. The experiments anticipating the construction of a molecular beam slower were carried out in the United States at the University of Texas at Austin. Femtosecond pump-probe techniques were employed to study the dynamics and electronic character of DNA bases, pairs and clusters in the gas phase. Experimentsnon DNA base monomers confirmed the dominance of a particular relaxation pathway, the npi* state. Competition between this state and another proposed relaxation pathway was demonstrated through observations of the DNA base pairs and base-water clusters, settling a recent controversy. Further, it was determined that the excited state dynamics in base pairs is due to intramolecular processes rather than intermolecular processes. Finally, results from base-water clusters confirm that microsolvation permits comparison with biologically relevant liquid phase experiments and with ab initio calculations, bridging a long-standing gap. A purely mechanical technique that does not rely upon quantum or electronic properties to produce very cold, very slow atoms and molecules would be more generally applicable than current approaches. The approach described here uses supersonic beam methods to produce a very cold beam of particles and a rotating paddle-wheel, or rotor, to slow the cold beam. Initial experiments testing the possibility of elastic scattering from a single crystal surface were conducted and the implications of these experiments are discussed.

  2. Beam position monitor multiplexer controller upgrade at the LAMPF proton storage ring

    International Nuclear Information System (INIS)

    Scarborough, W.K.; Cohen, S.

    1992-01-01

    The beam position monitor (BPM) is one of the primary diagnostic tools used for the tuning of the proton storage ring (PSR) at the Clinton P. Anderson Meson Physics Facility (LAMPF). A replacement for the existing, monolithic, wire-wrapped microprocessor-based BPM multiplexer controller has been built. The controller has been redesigned as a modular system retaining the same functionality of the original system built in 1981. Individual printed circuit cards are used for each controller function to insure greater maintainability and ease of keeping a spare parts inventory. Programmable logic device technology has substantially reduced the component count of the new controller. Diagnostic software was written to support the development of the upgraded controller. The new software actually uncovered some flaws in the original CAMAC interface. (author)

  3. Progress in computer-assisted diagnosis and control of neutral beam lines

    International Nuclear Information System (INIS)

    Theil, E.; Elischer, V.; Fiddler, J.; Jacobs, N.J.D.; Jacobson, V.; Lawhorn, R.; Uber, D.; Wilner, D.

    1981-01-01

    This paper discusses the principles that have guided the development of a computerized diagnostic and control system for both the Neutral Beam Systems Test Facility at Lawrence Berkeley Laboratory and the Doublet III neutral beams at the General Atomic Company. The emphasis is not on the particular details of the implementation, but on general considerations which have influenced the design criteria for the system. Foremost among these are the requirements of an appropriate human interface to the system, and effective use of a relational data base. Examples are used to illustrate how these principles are carried out in practice. A systems view of diagnostic programs is suggested in the light of our experience. (author)

  4. Apparatus and process for active pulse intensity control of laser beam

    Science.gov (United States)

    Wilcox, Russell B.

    1992-01-01

    An optically controlled laser pulse energy control apparatus and process is disclosed wherein variations in the energy of a portion of the laser beam are used to vary the resistance of a photodetector such as a photoresistor through which a control voltage is fed to a light intensity controlling device through which a second portion of the laser beam passes. Light attenuation means are provided to vary the intensity of the laser light used to control the resistance of the photodetector. An optical delay path is provided through which the second portion of the beam travels before reaching the light intensity controlling device. The control voltage is supplied by a variable power supply. The apparatus may be tuned to properly attenuate the laser beam passing through the intensity controlling device by adjusting the power supply, the optical delay path, or the light attenuating means.

  5. Beam-Based Error Identification and Correction Methods for Particle Accelerators

    CERN Document Server

    AUTHOR|(SzGeCERN)692826; Tomas, Rogelio; Nilsson, Thomas

    2014-06-10

    Modern particle accelerators have tight tolerances on the acceptable deviation from their desired machine parameters. The control of the parameters is of crucial importance for safe machine operation and performance. This thesis focuses on beam-based methods and algorithms to identify and correct errors in particle accelerators. The optics measurements and corrections of the Large Hadron Collider (LHC), which resulted in an unprecedented low β-beat for a hadron collider is described. The transverse coupling is another parameter which is of importance to control. Improvement in the reconstruction of the coupling from turn-by-turn data has resulted in a significant decrease of the measurement uncertainty. An automatic coupling correction method, which is based on the injected beam oscillations, has been successfully used in normal operation of the LHC. Furthermore, a new method to measure and correct chromatic coupling that was applied to the LHC, is described. It resulted in a decrease of the chromatic coupli...

  6. Fabrication and testing of SMA composite beam with shape control

    Science.gov (United States)

    Noolvi, Basavaraj; S, Raja; Nagaraj, Shanmukha; Mudradi, Varada Raj

    2017-07-01

    Smart materials are the advanced materials that have characteristics of sensing and actuation in response to the external stimuli like pressure, heat or electric charge etc. These materials can be integrated in to any structure to make it smart. From the different types of smart materials available, Shape Memory Alloy (SMA) is found to be more useful in designing new applications, which can offer more actuating speed, reduce the overall weight of the structure. The unique property of SMA is the ability to remember and recover from large strains of upto 8% without permanent deformation. Embedding the SMA wire/sheet in fiber-epoxy/flexible resin systems has many potential applications in Aerospace, Automobile, Medical, Robotics and various other fields. In this work the design, fabrication, and testing of smart SMA composite beam has been carried out. Two types of epoxy based resin systems namely LY 5210 resin system and EPOLAM 2063 resin system are used in fabricating the SMA composite specimens. An appropriate mould is designed and fabricated to retain the pre-strain of SMA wire during high temperature post curing of composite specimens. The specimens are fabricated using vacuum bag technique.

  7. Enhanced piezoelectric wind energy harvesting based on a buckled beam

    Science.gov (United States)

    Zhang, Jiantao; Zhang, Jia; Shu, Chang; Fang, Zhou

    2017-05-01

    In order to improve the wind energy conversion efficiency, this study entails a concept utilizing the buckling behavior of a buckled beam to induce large amplitude oscillations in a PVDF beam harvester. Specifically, when the buckled beam subjected to the buckling load is in an unstable condition, the wind load can trigger the drastic vibration of the PVDF beam harvester. Experimental results demonstrate that the output performances of the proposed harvester are improved dramatically compared with a traditional cantilever beam harvester.

  8. On models of layered piezoelectric beams for passive vibration control

    Science.gov (United States)

    Maurini, C.; dell'Isola, F.; Pouget, J.

    2004-06-01

    In this paper models of layered piezoelectric beams are discussed. The attention is focused on the analysis of the assumptions on transversal stress and strain distribution and their influence on the deduction of the beam constitutive equations from a three dimensional description. A model accounting for non trivial transversal interactions between different layers is deduced from a mixed variational formulation where non-local conditions on transversal stress are enforced by Lagrange multipliers method. The fully coupled electromechanical nature of the system is described. For a sandwich piezoelectric beam, analytical expressions of the beam constitutive coefficients are provided and comparisons to standard modelling approaches are presented. Finally, the fundamental features of the proposed model are highlighted by presenting the through-the-thickness distribution of the 3D state fields.

  9. Controllable diffraction of Gaussian beams with initial cross phase in nonlocal nonlinear media

    Science.gov (United States)

    Liang, Guo; Yang, Zhen-Jun

    2018-03-01

    An exact Gaussian beam solution with initial cross phase in nonlocal nonlinear media is presented in the strongly nonlocal limit. It is found that both the diffraction properties and the ellipticity of Gaussian beams closely depend on the cross-phase-front curvature. Because of the experimental controllability of the cross-phase-front curvature, the theoretical results pave the way to beam shaping in experiments.

  10. Improvements in or relating to the control of beams of electromagnetic radiation

    International Nuclear Information System (INIS)

    Cecil, M.M.; Michaelis, S.; Rumsby, P.T.

    1981-01-01

    A method of controlling the passage of a beam of laser radiation comprises generating in the beam path a transitory plasma of a density such as to prevent passage of the beam through the plasma. The apparatus comprises an evacuated chamber, with transparent walls and having means for generating at least 3 plasma plumes which coalesce in a localised region of the chamber. (U.K.)

  11. Cone-beam and fan-beam image reconstruction algorithms based on spherical and circular harmonics

    International Nuclear Information System (INIS)

    Zeng, Gengsheng L; Gullberg, Grant T

    2004-01-01

    A cone-beam image reconstruction algorithm using spherical harmonic expansions is proposed. The reconstruction algorithm is in the form of a summation of inner products of two discrete arrays of spherical harmonic expansion coefficients at each cone-beam point of acquisition. This form is different from the common filtered backprojection algorithm and the direct Fourier reconstruction algorithm. There is no re-sampling of the data, and spherical harmonic expansions are used instead of Fourier expansions. As a special case, a new fan-beam image reconstruction algorithm is also derived in terms of a circular harmonic expansion. Computer simulation results for both cone-beam and fan-beam algorithms are presented for circular planar orbit acquisitions. The algorithms give accurate reconstructions; however, the implementation of the cone-beam reconstruction algorithm is computationally intensive. A relatively efficient algorithm is proposed for reconstructing the central slice of the image when a circular scanning orbit is used

  12. 3D dictionary learning based iterative cone beam CT reconstruction

    Directory of Open Access Journals (Sweden)

    Ti Bai

    2014-03-01

    Full Text Available Purpose: This work is to develop a 3D dictionary learning based cone beam CT (CBCT reconstruction algorithm on graphic processing units (GPU to improve the quality of sparse-view CBCT reconstruction with high efficiency. Methods: A 3D dictionary containing 256 small volumes (atoms of 3 × 3 × 3 was trained from a large number of blocks extracted from a high quality volume image. On the basis, we utilized cholesky decomposition based orthogonal matching pursuit algorithm to find the sparse representation of each block. To accelerate the time-consuming sparse coding in the 3D case, we implemented the sparse coding in a parallel fashion by taking advantage of the tremendous computational power of GPU. Conjugate gradient least square algorithm was adopted to minimize the data fidelity term. Evaluations are performed based on a head-neck patient case. FDK reconstruction with full dataset of 364 projections is used as the reference. We compared the proposed 3D dictionary learning based method with tight frame (TF by performing reconstructions on a subset data of 121 projections. Results: Compared to TF based CBCT reconstruction that shows good overall performance, our experiments indicated that 3D dictionary learning based CBCT reconstruction is able to recover finer structures, remove more streaking artifacts and also induce less blocky artifacts. Conclusion: 3D dictionary learning based CBCT reconstruction algorithm is able to sense the structural information while suppress the noise, and hence to achieve high quality reconstruction under the case of sparse view. The GPU realization of the whole algorithm offers a significant efficiency enhancement, making this algorithm more feasible for potential clinical application.-------------------------------Cite this article as: Bai T, Yan H, Shi F, Jia X, Lou Y, Xu Q, Jiang S, Mou X. 3D dictionary learning based iterative cone beam CT reconstruction. Int J Cancer Ther Oncol 2014; 2(2:020240. DOI: 10

  13. A laser beam quality definition based on induced temperature rise.

    Science.gov (United States)

    Miller, Harold C

    2012-12-17

    Laser beam quality metrics like M(2) can be used to describe the spot sizes and propagation behavior of a wide variety of non-ideal laser beams. However, for beams that have been diffracted by limiting apertures in the near-field, or those with unusual near-field profiles, the conventional metrics can lead to an inconsistent or incomplete description of far-field performance. This paper motivates an alternative laser beam quality definition that can be used with any beam. The approach uses a consideration of the intrinsic ability of a laser beam profile to heat a material. Comparisons are made with conventional beam quality metrics. An analysis on an asymmetric Gaussian beam is used to establish a connection with the invariant beam propagation ratio.

  14. Control the length of beam trajectory with a quadruple triplet for heavy ion accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Zhan; Wei, Shaoqing; Lee, Sang Jin [Uiduk University, Gyeongju (Korea, Republic of); Kim, Do Gyun; Kim, Jang Youl [Rare Isotope Science Project, Institute for Basic Science, Daejeon (Korea, Republic of)

    2016-12-15

    Beam trajectory is needed to be controlled in heavy ion accelerator system. Quadruple magnets are widely used in heavy ion accelerator for focusing the transporting particles. A quadruple triplet system which consists of three consecutive quadrupoles, Q1, Q2 and Q3, is used to control beam trajectory at a focused position. Q1 and Q3 have symmetry with respect to Q2. The beam trajectory in magnet system is affected by higher order fields existed in real fields. For quadrupoles, the representation simulation of beam trajectory was carried out to study the beam trajectory and to estimate an effect of higher order field in triplet system. SCALA program was used to simulate the beam trajectory in OperaTM. SCALA can analyze a large number of beam trajectories at the same time by adjusting the size of finite element of the emitter. With OperaTM and MatlabTM programs, the position of focused beam spot in quadruple triplet system can be increased or decreased using evolution strategy (ES) method, therefore the length of triplet system can be controlled. Finally, the quadruple triplet system with the appropriate length and expected beam spot range was suggested in this paper.

  15. Arbitrary Control of Polarization and Intensity Profiles of Diffraction-Attenuation-Resistant Beams along the Propagation Direction

    Science.gov (United States)

    Corato-Zanarella, Mateus; Dorrah, Ahmed H.; Zamboni-Rached, Michel; Mojahedi, Mo

    2018-02-01

    We report on the theory and experimental generation of a class of diffraction-attenuation-resistant beams with state of polarization (SOP) and intensity that can be controlled on demand along the propagation direction. This control is achieved by a suitable superposition of Bessel beams, whose parameters are systematically chosen based on closed-form analytic expressions provided by the frozen waves method. Using an amplitude-only spatial light modulator, we experimentally demonstrate three scenarios. In the first, the SOP of a horizontally polarized beam evolves to radial polarization and is then changed to vertical polarization, with the beam intensity held constant. In the second, we simultaneously control the SOP and the longitudinal intensity profile, which is chosen such that the beam's central ring can be switched off over predefined space regions, thus generating multiple foci with different SOPs and at different intensity levels along the propagation. Finally, the ability to control the SOP while overcoming attenuation inside lossy fluids is shown experimentally. We envision our proposed method to be of great interest for many applications, such as optical tweezers, atom guiding, material processing, microscopy, and optical communications.

  16. Small, microcomputer-based CAMAC controller

    International Nuclear Information System (INIS)

    Juras, R.C.

    1979-01-01

    The beam buncher necessary to condition the beam from the Oak Ridge National Laboratory 25 MV tandem accelerator for post-acceleration by the Oak Ridge Isochronous Cyclotron is CAMAC-based and will be controlled via one of the serial highways of the accelerator control system. However, prior to integration into the accelerator system, the buncher requires testing, including runs on the model EN tandem at Oak Ridge. In order to facilitate testing and initial operation of the buncher, a microcomputer-based controller was assembled. The controller consists of a CAMAC crate, several CAMAC modules, a touch panel display, a controller box, and software. The controller box contains one shaft encoder and two switches. One of the switches is a coarse/fine selector. The other switch is assignable via the touch panel display and is used, for example, to turn devices on and off. Operation of the controller is described. It can be quickly assembled to control any small CAMAC-based system. 2 figures

  17. Size Control Technology of Silver Nanoparticles Using Electron Beam Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Hyun Suk; Kim, Byungnam; Kim, Hye Won; Koo, Yong Hwan; Lee, Byung Cheol [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Park, Ji Hyun [Univ. of Science and Technology, Daejeon (Korea, Republic of); Bae, Hyung Bin [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of); Park, Changmoon [Chungnam National Univ., Daejeon (Korea, Republic of)

    2013-12-15

    The manufacturing of silver nanoparticles using an electron beam is easy, fast, and highly productive, and it is possible at room temperature with no chemical residuals. Its various advantages therefore make this an important method for manufacturing nanoparticles such as silver, copper, and platinum. In particular, despite the use of electron beam irradiation, the results show that this method makes it possible to produce silver nanoparticles at low cost since low beam energy and low doses are used. This means that middle and high-energy electron beam accelerators are very expensive, but a low-energy electron beam accelerator has a relatively low cost of around 4-5 times, and mass production for a flow reaction without the need for extra radiation shielding is possible. Silver nanoparticles are of great interest to many researchers owing to their ability to be used in many applications such as catalysis, nanoelectronics, optical filters, electromagnetic interference shielding, surface Raman scattering, medical supplies, fabrics, cosmetics, hygiene and kitchen supplies, and electric home appliances.

  18. Size Control Technology of Silver Nanoparticles Using Electron Beam Irradiation

    International Nuclear Information System (INIS)

    Kang, Hyun Suk; Kim, Byungnam; Kim, Hye Won; Koo, Yong Hwan; Lee, Byung Cheol; Park, Ji Hyun; Bae, Hyung Bin; Park, Changmoon

    2013-01-01

    The manufacturing of silver nanoparticles using an electron beam is easy, fast, and highly productive, and it is possible at room temperature with no chemical residuals. Its various advantages therefore make this an important method for manufacturing nanoparticles such as silver, copper, and platinum. In particular, despite the use of electron beam irradiation, the results show that this method makes it possible to produce silver nanoparticles at low cost since low beam energy and low doses are used. This means that middle and high-energy electron beam accelerators are very expensive, but a low-energy electron beam accelerator has a relatively low cost of around 4-5 times, and mass production for a flow reaction without the need for extra radiation shielding is possible. Silver nanoparticles are of great interest to many researchers owing to their ability to be used in many applications such as catalysis, nanoelectronics, optical filters, electromagnetic interference shielding, surface Raman scattering, medical supplies, fabrics, cosmetics, hygiene and kitchen supplies, and electric home appliances

  19. A new electromagnetic shunt damping treatment and vibration control of beam structures

    International Nuclear Information System (INIS)

    Niu Hongpan; Zhang Xinong; Xie Shilin; Wang Pengpeng

    2009-01-01

    In this paper a new class of shunted electromagnetic damping treatment is proposed: a non-contact electromagnetic shunt damper (NC-EMSD). The NC-EMSD consists of an electromagnet attached to a host structure, a permanent magnet attached to the fixed boundary and an electrical impedance connected to the terminals of the electromagnet. The electromagnet and the shunt impedance constitute a closed circuit. When the structure vibrates, an induced electromotive force will be produced and results in the electromagnetic force as damping force, which can suppress the vibration of the structure. The model of NC-EMSD is built up based on the equivalent current method. The governing equations of the beam with NC-EMSD are established using Hamilton's principle. The capacitor-matching-inductance (CMI) method and the negative resistive capacitor-matching-inductance (NR-CMI) method are proposed, respectively. Then the vibration control of a cantilever beam with NC-EMSD is simulated and measured by CMI and NR-CMI control methods, respectively. The results show that both the CMI and NR-CMI can attenuate the vibration effectively, and the NR-CMI provides much better control performance than that by CMI. It is indicated as well from the studies that the decrease of either the gap between the magnet pair or the resistance of the shunt impedance contributes to the improvement of control performance

  20. Beam-Based Alignment of Magnetic Field in the Fermilab Electron Cooler Cooling Section

    International Nuclear Information System (INIS)

    Seletskiy, S. M.; Tupikov, V.

    2006-01-01

    The Fermilab Electron Cooling Project requires low effective anglular spread of electrons in the cooling section. One of the main components of the effective electron angles is an angle of electron beam centroid with respect to antiproton beam. This angle is caused by the poor quality of magnetic field in the 20 m long cooling section solenoid and by the mismatch of the beam centroid to the entrance of the cooling section. This paper focuses on the beam-based procedure of the alignment of the cooling section field and beam centroid matching. The discussed procedure allows to suppress the beam centroid angles below the critical value of 0.1 mrad

  1. Methodological demonstration of laser beam pointing control for space gravitational wave detection missions.

    Science.gov (United States)

    Dong, Yu-Hui; Liu, He-Shan; Luo, Zi-Ren; Li, Yu-Qiong; Jin, Gang

    2014-07-01

    In space laser interferometer gravitational wave (G.W.) detection missions, the stability of the laser beam pointing direction has to be kept at 10 nrad/√Hz. Otherwise, the beam pointing jitter noise will dominate the noise budget and make the detection of G.W. impossible. Disturbed by the residue non-conservative forces, the fluctuation of the laser beam pointing direction could be a few μrad/√Hz at frequencies from 0.1 mHz to 10 Hz. Therefore, the laser beam pointing control system is an essential requirement for those space G.W. detection missions. An on-ground test of such beam pointing control system is performed, where the Differential Wave-front Sensing technique is used to sense the beams pointing jitter. An active controlled steering mirror is employed to adjust the beam pointing direction to compensate the jitter. The experimental result shows that the pointing control system can be used for very large dynamic range up to 5 μrad. At the interested frequencies of space G.W. detection missions, between 1 mHz and 1 Hz, beam pointing stability of 6 nrad/√Hz is achieved.

  2. The Utrecht 850 kV cascade generator I. Beam deflection and energy control

    NARCIS (Netherlands)

    Braams, C.M.; Smith, P.B.

    The beam deflection magnet and energy control system of the Utrecht cascade generator are described. The uniform-field magnet has entrance and exit slits located outside the magnetic held. Since the cascade generator produces a vertical beam, the most convenient choice for the angle of deflection

  3. Control of the beam-internal target interaction at the nuclotron by means of light radiation

    Energy Technology Data Exchange (ETDEWEB)

    Artiomov, A.S. [Laboratory of High Energies, Joint Institute for Nuclear Research, Dubna 141980 (Russian Federation)]. E-mail: artiomov@moonhe.jinr.ru; Anisimov, Yu.S. [Laboratory of High Energies, Joint Institute for Nuclear Research, Dubna 141980 (Russian Federation); Afanasiev, S.V. [Laboratory of High Energies, Joint Institute for Nuclear Research, Dubna 141980 (Russian Federation); Bazilev, S.N. [Laboratory of High Energies, Joint Institute for Nuclear Research, Dubna 141980 (Russian Federation); Zolin, L.S. [Laboratory of High Energies, Joint Institute for Nuclear Research, Dubna 141980 (Russian Federation); Issinsky, I.B. [Laboratory of High Energies, Joint Institute for Nuclear Research, Dubna 141980 (Russian Federation); Kliman, J. [Laboratory of High Energies, Joint Institute for Nuclear Research, Dubna 141980 (Russian Federation); Institute of Physics, Slovak Academy of Sciences, Bratislava (Slovakia); Malakhov, A.I. [Laboratory of High Energies, Joint Institute for Nuclear Research, Dubna 141980 (Russian Federation); Matousek, V. [Institute of Physics, Slovak Academy of Sciences, Bratislava (Slovakia); Morhac, M. [Laboratory of High Energies, Joint Institute for Nuclear Research, Dubna 141980 (Russian Federation); Institute of Physics, Slovak Academy of Sciences, Bratislava (Slovakia); Nikitin, V.A. [Laboratory of High Energies, Joint Institute for Nuclear Research, Dubna 141980 (Russian Federation); Nikiforov, A.S. [Laboratory of High Energies, Joint Institute for Nuclear Research, Dubna 141980 (Russian Federation); Nomokonov, P.V. [Laboratory of High Energies, Joint Institute for Nuclear Research, Dubna 141980 (Russian Federation); Pilyar, A.V. [Laboratory of High Energies, Joint Institute for Nuclear Research, Dubna 141980 (Russian Federation); Turzo, I. [Institute of Physics, Slovak Academy of Sciences, Bratislava (Slovakia)

    2005-02-11

    The light radiation from various internal targets at the nuclotron can be utilized for the operative control and time optimization of the interaction intensity of the beam. The examples presented in the paper illustrate information about the space characteristics of the circulating beam during one cycle of the accelerator run at the stages of injection, acceleration and during the physical experiments, respectively.

  4. Methodological demonstration of laser beam pointing control for space gravitational wave detection missions

    Energy Technology Data Exchange (ETDEWEB)

    Dong, Yu-Hui; Liu, He-Shan [National Microgravity Laboratory (NML), Institute of Mechanics, Chinese Academy of Sciences, Beijing 100190 (China); University of Chinese Academy of Sciences, Beijing 100190 (China); Luo, Zi-Ren; Li, Yu-Qiong; Jin, Gang, E-mail: gajin@imech.ac.cn [National Microgravity Laboratory (NML), Institute of Mechanics, Chinese Academy of Sciences, Beijing 100190 (China)

    2014-07-15

    In space laser interferometer gravitational wave (G.W.) detection missions, the stability of the laser beam pointing direction has to be kept at 10 nrad/√Hz. Otherwise, the beam pointing jitter noise will dominate the noise budget and make the detection of G.W. impossible. Disturbed by the residue non-conservative forces, the fluctuation of the laser beam pointing direction could be a few μrad/√Hz at frequencies from 0.1 mHz to 10 Hz. Therefore, the laser beam pointing control system is an essential requirement for those space G.W. detection missions. An on-ground test of such beam pointing control system is performed, where the Differential Wave-front Sensing technique is used to sense the beams pointing jitter. An active controlled steering mirror is employed to adjust the beam pointing direction to compensate the jitter. The experimental result shows that the pointing control system can be used for very large dynamic range up to 5 μrad. At the interested frequencies of space G.W. detection missions, between 1 mHz and 1 Hz, beam pointing stability of 6 nrad/√Hz is achieved.

  5. Nanomanufacturing of titania interfaces with controlled structural and functional properties by supersonic cluster beam deposition

    Energy Technology Data Exchange (ETDEWEB)

    Podestà, Alessandro, E-mail: alessandro.podesta@mi.infn.it, E-mail: pmilani@mi.infn.it; Borghi, Francesca; Indrieri, Marco; Bovio, Simone; Piazzoni, Claudio; Milani, Paolo, E-mail: alessandro.podesta@mi.infn.it, E-mail: pmilani@mi.infn.it [Centro Interdisciplinare Materiali e Interfacce Nanostrutturati (C.I.Ma.I.Na.), Dipartimento di Fisica, Università degli Studi di Milano, via Celoria 16, 20133 Milano (Italy)

    2015-12-21

    Great emphasis is placed on the development of integrated approaches for the synthesis and the characterization of ad hoc nanostructured platforms, to be used as templates with controlled morphology and chemical properties for the investigation of specific phenomena of great relevance in interdisciplinary fields such as biotechnology, medicine, and advanced materials. Here, we discuss the crucial role and the advantages of thin film deposition strategies based on cluster-assembling from supersonic cluster beams. We select cluster-assembled nanostructured titania (ns-TiO{sub 2}) as a case study to demonstrate that accurate control over morphological parameters can be routinely achieved, and consequently, over several relevant interfacial properties and phenomena, like surface charging in a liquid electrolyte, and proteins and nanoparticles adsorption. In particular, we show that the very good control of nanoscale morphology is obtained by taking advantage of simple scaling laws governing the ballistic deposition regime of low-energy, mass-dispersed clusters with reduced surface mobility.

  6. Nanomanufacturing of titania interfaces with controlled structural and functional properties by supersonic cluster beam deposition

    International Nuclear Information System (INIS)

    Podestà, Alessandro; Borghi, Francesca; Indrieri, Marco; Bovio, Simone; Piazzoni, Claudio; Milani, Paolo

    2015-01-01

    Great emphasis is placed on the development of integrated approaches for the synthesis and the characterization of ad hoc nanostructured platforms, to be used as templates with controlled morphology and chemical properties for the investigation of specific phenomena of great relevance in interdisciplinary fields such as biotechnology, medicine, and advanced materials. Here, we discuss the crucial role and the advantages of thin film deposition strategies based on cluster-assembling from supersonic cluster beams. We select cluster-assembled nanostructured titania (ns-TiO 2 ) as a case study to demonstrate that accurate control over morphological parameters can be routinely achieved, and consequently, over several relevant interfacial properties and phenomena, like surface charging in a liquid electrolyte, and proteins and nanoparticles adsorption. In particular, we show that the very good control of nanoscale morphology is obtained by taking advantage of simple scaling laws governing the ballistic deposition regime of low-energy, mass-dispersed clusters with reduced surface mobility

  7. Operating experience with LAMPF main beam lines instrumentation and control system

    International Nuclear Information System (INIS)

    van Dyck, O.B.; Harvey, A.; Howard, H.H.; Roeder, D.L.

    1975-01-01

    Instrumentation and control (I and C) for the Los Alamos Clinton P. Anderson Meson Physics Facility (LAMPF) main beam line is based upon central computer control through remote stations which provide input and output to most devices. Operating experience shows that the ability of the computer to give high-quality graphical presentation of the measurements enhances operator performance and instrument usefulness. Experience also shows that operator efficiency degrades rapidly with increasing instrument response time, that is, with increasing delay between the time a control is changed and the result can be observed. For this reason, instrumentation upgrade includes speeding up data acquisition and display times to under 10 s. Similarly, television-viewed phosphors are being retained where possible since their instantaneous response is very useful. Other upgrading of the instrumentation system is planned to improve data accuracy, reliability, redundancy, and instrument radiation tolerance. Past experience is being applied in adding or relocating devices to simplify tuning procedures. (U.S.)

  8. Mask writing time explosion and its effect on CD control in e-beam lithography

    Science.gov (United States)

    Lee, Sang Hee; Choi, Jin; Min, Seong Jun; Kim, Hee Bom; Kim, Byung Gook; Woo, Sang-Gyun; Cho, Han-Ku

    2010-05-01

    As semiconductor features shrink in size and pitch, the extreme control of CD uniformity and MTT is needed for mask fabrication with e-beam lithography. And because of huge shot density of data, the writing time of e-beam lithography for mask fabrication will be increased rapidly in future design node. The beam drift caused by charging of optic system and current density drift can affect the beam size, position and exposure dose stability. From the empirical data, those are the function of writing time. Although e-beam lithography tool has the correction function which can be applied during writing, there are remained errors after correction which result in CD uniformity error. According to the writing time increasing, the residual error of correction will be more important and give the limit of CD uniformity and MTT. In this study, we study the beam size and exposure dose error as a function of time. Those are mainly caused by charging and current density drift. And we present the predicted writing time of e-beam lithography below 32nm node and estimate its effect on CD control error. From the relation between writing time and CD control error, we achieve the limit of CD uniformity with e-beam mask writer. And we suggest the method to achieve required CD uniformity at 22nm node and beyond.

  9. A micropulse monitor for control of cyclotron beams

    Science.gov (United States)

    Lind, D. A.; Peterson, R. J.; Da Silva, A. G.; Auler, L. T.; de Barros, S.

    1990-07-01

    A system using wall current monitors to observe the time structure of the individual beam current pulses of the Cyclotron Corp. CV28 cyclotron installed at the Instituto de Engenharia Nuclear of CNEN in Rio de Janeiro is described. The monitors are designed to give a faithful representation of the actual beam pulse, so the effects on the longitudinal phase space could be seen as the cyclotron parameters were changed. Beam pulses of width in the range of 1 to 4 ns and with a charge of 7 × 10-16 C or greater can be observed. With two units in the line transit times permit beam energy determination as well as charge distribution. For timing purposes a unit placed in front of a target is used to generate a start signal for time-of-flight measurements, and to monitor the effects of all parameters of the cyclotron tune. By measuring flight times in the beamlines of this machine, the energy for 28 MeV protons can be determined to about 50 keV and for the other available particles to about 30 keV.

  10. Micromirror-based manipulation of synchrotron x-ray beams

    Science.gov (United States)

    Walko, D. A.; Chen, Pice; Jung, I. W.; Lopez, D.; Schwartz, C. P.; Shenoy, G. K.; Wang, Jin

    2017-08-01

    Synchrotron beamlines typically use macroscopic, quasi-static optics to manipulate x-ray beams. We present the use of dynamic microelectromechanical systems-based optics (MEMS) to temporally modulate synchrotron x-ray beams. We demonstrate this concept using single-crystal torsional MEMS micromirrors oscillating at frequencies of 75 kHz. Such a MEMS micromirror, with lateral dimensions of a few hundred micrometers, can interact with x rays by operating in grazing-incidence reflection geometry; x rays are deflected only when an x-ray pulse is incident on the rotating micromirror under appropriate conditions, i.e., at an angle less than the critical angle for reflectivity. The time window for such deflections depends on the frequency and amplitude of the MEMS rotation. We demonstrate that reflection geometry can produce a time window of a few microseconds. We further demonstrate that MEMS optics can isolate x rays from a selected synchrotron bunch or group of bunches. With ray-trace simulations we explain the currently achievable time windows and suggest a path toward improvements.

  11. Beam Diagnostics for Laser Undulator Based on Compton Backward Scattering

    CERN Document Server

    Kuroda, R

    2005-01-01

    A compact soft X-ray source is required in various research fields such as material and biological science. The laser undulator based on Compton backward scattering has been developed as a compact soft X-ray source for the biological observation at Waseda University. It is performed in a water window region (250eV - 500 eV) using the interaction between 1047 nm Nd:YLF laser (10ps FWHM) and about 5 MeV high quality electron beam (10ps FWHM) generated from rf gun system. The range of X-ray energy in the water window region has K-shell absorption edges of Oxygen, Carbon and Nitrogen, which mainly constitute of living body. Since the absorption coefficient of water is much smaller than the protein's coefficient in this range, a dehydration of the specimens is not necessary. To generate the soft X-ray pulse stably, the electron beam diagnostics have been developed such as the emittance measurement using double slit scan technique, the bunch length measurement using two frequency analysis technique. In this confere...

  12. Control and monitoring systems for electron beam flue gas treatment technology

    International Nuclear Information System (INIS)

    Chmielewski, A.G.; Licki, J.; Mazurekc, J.; Nelskic, L.; Sobolewskic, L.

    2011-01-01

    The reliable and accurate measurements of gas parameters in essential points of industrial plant are necessary for its proper operation and control. Natural flue gases there are only at the inlet. At other points of plant gas parameters are strongly modified by process control system. The principal role of process monitoring system is to provide the Computer System for Monitoring and Control with continuous recording of process parameters. The main goal of control system is to obtain the optimal SO 2 and NO x removal efficiencies by control of amount of spray water at the spray cooler, amount of NH 3 injection to flue gas and adjustment of electron beam current. The structure of the process control system is based on algorithms describing functional dependence of SO 2 and NO x removal efficiencies. The best available techniques should be applied for measurements of flue gases parameters at essential points of installation and for digital control system to assist plant operators in the analysis and optimization of plant operation, including integrated emission control. (author)

  13. National Ignition Facility, subsystem design requirements beam control and laser diagnostics SSDR 1.7

    International Nuclear Information System (INIS)

    Bliss, E.

    1996-01-01

    This Subsystem Design Requirement document is a development specification that establishes the performance, design, development, and test requirements for the Alignment subsystem (WBS 1.7.1), Beam Diagnostics (WBS 1.7.2), and the Wavefront Control subsystem (WBS 1.7. 3) of the NIF Laser System (WBS 1.3). These three subsystems are collectively referred to as the Beam Control ampersand Laser Diagnostics Subsystem. The NIF is a multi-pass, 192-beam, high-power, neodymium-glass laser that meets requirements set forth in the NIF SDR 002 (Laser System). 3 figs., 3 tabs

  14. Materials of the Regional Training Course on Validation and Process Control for Electron Beam Radiation Processing

    International Nuclear Information System (INIS)

    Kaluska, I.; Gluszewski, W.

    2007-01-01

    Irradiation with electron beams is used in the polymer industry, food, pharmaceutical and medical device industries for sterilization of surfaces. About 20 lectures presented during the Course were devoted to all aspects of control and validation of low energy electron beam processes. They should help the product manufacturers better understand the application of the ANSI/AAMI/ISO 11137 norm, which defines the requirements and standard practices for validation of the irradiation process and the process controls required during routine processing

  15. Automatic beam position control at Los Alamos Spallation Radiation Effects Facility (LASREF)

    International Nuclear Information System (INIS)

    Oothoudt, M.; Pillai, C.; Zumbro, M.

    1997-01-01

    Historically the Los Alamos Spallation Radiation Effects Facility (LASREF) has used manual methods to control the position of the 800 kW, 800 MeV proton beam on targets. New experiments, however, require more stringent position control more frequently than can be done manually for long periods of time. Data from an existing harp is used to automatically adjust steering magnets to maintain beam position to required tolerances

  16. Spill control and intensity monitoring for the Bevatron--Bevalac external particle beams

    International Nuclear Information System (INIS)

    Barale, J.J.; Crebbin, K.C.

    1975-03-01

    Time-intensity modulation in beam spill can be of primary concern in some experiments. The major source of this beam structure is from main-guide field-magnet power supply ripple. If the time constants are appropriate, then final control of beam structure can be accomplished by closed loop control of the intensity of beam spill. The response characteristics of the feedback system will determine the final structure. At high beam fluxes signal to noise ratio of beam detectors, in the feedback loop, can be improved by at least four orders of magnitude by using photomultiplier tubes and a water Cherenkov counter in place of the normal secondary emission monitor. At beam fluxes below 10 10 particles per second (PPS), a plastic scintillator and photomultiplier tube are used in the feedback system. A plastic scintillator and photomultiplier are also used in the beam as intensity monitors. At intensities below about 10 7 PPS standard counting techniques are used. For intensities between 10 6 to 110 9 PPS, the photomultiplier is used as a current source driving an integrating circuit which is then calibrated to read the number of particles per pulse. (U.S.)

  17. Electron beam based transversal profile measurements of intense ion beams; Elektronenstrahl-Diagnostik zur Bestimmung vom transversalen Profil intensiver Ionenstrahlen

    Energy Technology Data Exchange (ETDEWEB)

    El Moussati, Said

    2014-11-03

    A non-invasive diagnostic method for the experimental determination of the transverse profile of an intense ion beam has been developed and investigated theoretically as well as experimentally within the framework of the present work. The method is based on the deflection of electrons when passing the electromagnetic field of an ion beam. To achieve this an electron beam is employed with a specifically prepared transversal profile. This distinguish this method from similar ones which use thin electron beams for scanning the electromagnetic field [Roy et al. 2005; Blockland10]. The diagnostic method presented in this work will be subsequently called ''Electron-Beam-Imaging'' (EBI). First of all the influence of the electromagnetic field of the ion beam on the electrons has been theoretically analyzed. It was found that the magnetic field causes only a shift of the electrons along the ion beam axis, while the electric field only causes a shift in a plane transverse to the ion beam. Moreover, in the non-relativistic case the magnetic force is significantly smaller than the Coulomb one and the electrons suffer due to the magnetic field just a shift and continue to move parallel to their initial trajectory. Under the influence of the electric field, the electrons move away from the ion beam axis, their resulting trajectory shows a specific angle compared to the original direction. This deflection angle practically depends just on the electric field of the ion beam. Thus the magnetic field has been neglected when analysing the experimental data. The theoretical model provides a relationship between the deflection angle of the electrons and the charge distribution in the cross section of the ion beam. The model however only can be applied for small deflection angles. This implies a relationship between the line-charge density of the ion beam and the initial kinetic energy of the electrons. Numerical investigations have been carried out to clarify the

  18. Optical Wireless Communications and Autonomous Beam Control Moving User Terminal

    OpenAIRE

    TANGTRONGBENCHASIL, Charoen; HAMADA, Yoichi; KATO, Toshihiro; NONAKA, Koji

    2007-01-01

    Optical wireless communications is a research topic of extreme interest since it offers high data rate (Gbps data rate), security, and RF interference immunity. However, optical wireless communications places severe restrictions on the communications paths; they must be direct beam connections. To increase the number of users and link robustness, optical wireless communications must be able to operate even when obstacles are placed between transmitters and receivers, so optical micro-cell (OM...

  19. Progress in control and data acquisition for the ITER neutral beam test facility

    Energy Technology Data Exchange (ETDEWEB)

    Luchetta, Adriano, E-mail: adriano.luchetta@igi.cnr.it [Consorzio RFX, Euratom-ENEA Association, Padova (Italy); Manduchi, Gabriele; Taliercio, Cesare; Soppelsa, Anton [Consorzio RFX, Euratom-ENEA Association, Padova (Italy); Paolucci, Francesco; Sartori, Filippo [Fusion for Energy, Barcelona (Spain); Barbato, Paolo; Capobianco, Roberto; Breda, Mauro; Molon, Federico; Moressa, Modesto; Polato, Sandro; Simionato, Paola; Zampiva, Enrico [Consorzio RFX, Euratom-ENEA Association, Padova (Italy)

    2013-10-15

    Highlights: ► An ion source experiment, referred to as SPIDER, is under construction in the ITER neutral beam test facility. ► The progress in designing and testing the SPIDER control and data acquisition system is reported. ► An original approach is proposed in using ITER CODAC and non-ITER CODAC technology. -- Abstract: SPIDER, the ion source test bed in the ITER neutral beam test facility, is under construction and its operation is expected to start in 2014. Control and data acquisition for SPIDER are undergoing final design. SPIDER CODAS, as the control and data acquisition system is referred to, is requested to manage 25 plant units, to acquire 1000 analogue signals with sampling rates ranging from a few S/s to 10 MS/s, to acquire images with up to 100 frames per second, to operate with long pulses lasting up to 1 h, and to sustain 200 MB/s data throughput into the data archive with an annual data storage amount of up to 50 TB. SPIDER CODAS software architecture integrates three open-source software frameworks each addressing specific system requirements. Slow control exploits the synergy among EPICS and Siemens S7 programmable controllers. Data handling is by MDSplus a data-centric framework that is geared towards the collection and organization of scientific data. Diagnostics based on imaging drive the design of data throughput and archive size. Fast control is implemented by using MARTe, a data-driven, object-oriented, real-time environment. The paper will describe in detail the progress of the system hardware and software architecture and will show how the software frameworks interact to provide the functions requested by SPIDER CODAS. The paper will focus on how the performance requirements can be met with the described SPIDER CODAS architecture, describing the progress achieved by carrying out prototyping activities.

  20. Monolithic millimeter-wave diode array beam controllers: Theory and experiment

    Science.gov (United States)

    Sjogren, L. B.; Liu, H.-X. L.; Wang, F.; Liu, T.; Wu, W.; Qin, X.-H.; Chung, E.; Domier, C. W.; Luhmann, N. C., Jr.; Maserjian, J.

    1992-01-01

    In the current work, multi-function beam control arrays have been fabricated and have successfully demonstrated amplitude control of transmitted beams in the W and D bands (75-170 GHz). While these arrays are designed to provide beam control under DC bias operation, new designs for high-speed electronic and optical control are under development. These arrays will fill a need for high-speed watt-level beam switches in pulsed reflectometer systems under development for magnetic fusion plasma diagnostics. A second experimental accomplishment of the current work is the demonstration in the 100-170 GHz (D band) frequency range of a new technique for the measurement of the transmission phase as well as amplitude. Transmission data can serve as a means to extract ('de-embed') the grid parameters; phase information provides more complete data to assist in this process. Additional functions of the array beam controller yet to be tested include electronically controlled steering and focusing of a reflected beam. These have application in the areas of millimeter-wave electronic scanning radar and reflectometry, respectively.

  1. Control of surface ripple amplitude in ion beam sputtered polycrystalline cobalt films

    Energy Technology Data Exchange (ETDEWEB)

    Colino, Jose M., E-mail: josemiguel.colino@uclm.es [Institute of Nanoscience, Nanotechnology and Molecular Materials, University of Castilla-La Mancha, Campus de la Fabrica de Armas, Toledo 45071 (Spain); Arranz, Miguel A. [Facultad de Ciencias Quimicas, University of Castilla-La Mancha, Ciudad Real 13071 (Spain)

    2011-02-15

    We have grown both polycrystalline and partially textured cobalt films by magnetron sputter deposition in the range of thickness (50-200 nm). Kinetic roughening of the growing film leads to a controlled rms surface roughness values (1-6 nm) increasing with the as-grown film thickness. Ion erosion of a low energy 1 keV Ar+ beam at glancing incidence (80{sup o}) on the cobalt film changes the surface morphology to a ripple pattern of nanometric wavelength. The wavelength evolution at relatively low fluency is strongly dependent on the initial surface topography (a wavelength selection mechanism hereby confirmed in polycrystalline rough surfaces and based on the shadowing instability). At sufficiently large fluency, the ripple wavelength steadily increases on a coarsening regime and does not recall the virgin surface morphology. Remarkably, the use of a rough virgin surface makes the ripple amplitude in the final pattern can be controllably increased without affecting the ripple wavelength.

  2. Adaptive Boundary Iterative Learning Control for an Euler-Bernoulli Beam System With Input Constraint.

    Science.gov (United States)

    He, Wei; Meng, Tingting; Huang, Deqing; Li, Xuefang

    2017-03-15

    This paper addresses the vibration control and the input constraint for an Euler-Bernoulli beam system under aperiodic distributed disturbance and aperiodic boundary disturbance. Hyperbolic tangent functions and saturation functions are adopted to tackle the input constraint. A restrained adaptive boundary iterative learning control (ABILC) law is proposed based on a time-weighted Lyapunov-Krasovskii-like composite energy function. In order to deal with the uncertainty of a system parameter and reject the external disturbances, three adaptive laws are designed and learned in the iteration domain. All the system states of the closed-loop system are proved to be bounded in each iteration. Along the iteration axis, the displacements asymptotically converge toward zero. Simulation results are provided to illustrate the effectiveness of the proposed ABILC scheme.

  3. Process qualification and control in electron beams--requirements, methods, new concepts and challenges

    International Nuclear Information System (INIS)

    Mittendorfer, J.; Gratzl, F.; Hanis, D.

    2004-01-01

    In this paper the status of process qualification and control in electron beam irradiation is analyzed in terms of requirements, concepts, methods and challenges for a state-of-the-art process control concept for medical device sterilization. Aspects from process qualification to routine process control are described together with the associated process variables. As a case study the 10 MeV beams at Mediscan GmbH are considered. Process control concepts like statistical process control (SPC) and a new concept to determine process capability is briefly discussed

  4. Radioactive nuclear beam facilities based on projectile fragmentation

    International Nuclear Information System (INIS)

    Sherrill, B.M.

    1992-01-01

    The production of radioactive beams using direct separation techniques is discussed. The reaction mechanisms which can be used to produce radioactive beams with these techniques can be broadly divided into three groups, projectile fragmentation, nucleon transfer, and Coulomb disassociation. Radioactive nuclei produced in these ways have large forward momenta with relatively sharp angular distributions peaked near zero degrees which are suitable for collection with magnetic devices. Secondary beam intensities of up to a few percent of the primary beam intensity are possible, although depending on the production mechanism the beam emittance may be poor. Further beam purification can be achieved using atomic processes with profiled energy degraders. The features of the production reaction mechanism, separation techniques, and a review of world wide efforts are presented. The advantages and disadvantages of the method are presented, with discussion of techniques to overcome some of the disadvantages. (Author)

  5. ROBUST MIXED H2/H8 ACTIVE VIBRATION CONTROLLER IN ATTENUATION OF SMART BEAM

    Directory of Open Access Journals (Sweden)

    Atta Oveisi

    2014-12-01

    Full Text Available The lack of robustness of the mechanical systems due to the unmodeled dynamics and the external disturbances withholds the performance and optimality of the structures. In this paper, this deficiency is obviated in order to reach the desired robust stability and performance on smart structures. For this purpose a multi-objective robust control strategy is proposed for vibration suppression of a clamped-free smart beam with piezoelectric actuator and vibrometer sensor in an LMI framework which is capable of handling weighted exogenous input signals and provides desired pole placement and robust performance at the same time. An accurate model of a homogeneous beam is derived by means of the finite element modal analysis. Then a low order modal system is considered as the nominal model and remaining modes are left as the multiplicative unstructured uncertainty. Next, a robust controller with a regional pole placement constraint is designed based on the augmented plant composed of the nominal model and its accompanied uncertainty by solving a convex optimization problem. Finally, the robustness of the uncertain closed-loop model and the effect of performance index weights on the system output are investigated both in simulation and practice.

  6. Particle beam technology for control of atomic-bonding state in materials

    Energy Technology Data Exchange (ETDEWEB)

    Ishikawa, Junzo [Kyoto Univ. (Japan). Faculty of Engineering

    1997-03-01

    The atomic-bonding state in materials can be controlled through `kinetic bonding` process by energetic particle beams which have a sufficient atomic kinetic energy. In order to clarify the `kinetic bonding` process the negative-ion beam deposition is considered as an ideal method because the negative ion has no additional active energies. Sputter type heavy negative-ion sources can be used for this purpose. Carbon films prepared by carbon negative-ion beam deposition have a strong dependency of the film properties on ion beam kinetic energy and have a quite high thermal conductivity which is comparable to that of the IIb diamond at a kinetic energy of 50-100 eV/atom. It suggests that new or metastable materials could be formed through the `kinetic bonding` process. Negative-ion beams can also be used for ion implantation, in which charging problems are perfectly reduced. (author)

  7. Accelerator development for a radioactive beam facility based on ATLAS

    International Nuclear Information System (INIS)

    Shepard, K. W.

    1998-01-01

    The existing superconducting linac ATLAS is in many respects an ideal secondary beam accelerator for an ISOL (Isotope separator on-line) type radioactive beam facility. Such a facility would require the addition of two major accelerator elements: a low charge state injector for the existing heavy ion linac, and a primary beam accelerator providing 220 MV of acceleration for protons and light ions. Development work for both of these elements, including the option of superconducting cavities for the primary beam accelerator is discussed

  8. Accelerator development for a radioactive beam facility based on ATLAS.

    Energy Technology Data Exchange (ETDEWEB)

    Shepard, K. W.

    1998-01-08

    The existing superconducting linac ATLAS is in many respects an ideal secondary beam accelerator for an ISOL (Isotope separator on-line) type radioactive beam facility. Such a facility would require the addition of two major accelerator elements: a low charge state injector for the existing heavy ion linac, and a primary beam accelerator providing 220 MV of acceleration for protons and light ions. Development work for both of these elements, including the option of superconducting cavities for the primary beam accelerator is discussed.

  9. Recent improvements to the DIII-D neutral beam instrumentation and control system

    International Nuclear Information System (INIS)

    Kellman, D.H.; Hong, R.

    1997-11-01

    The DIII-D neutral beam (NB) instrumentation and control (I and C) system provides for operational control and synchronization of the eight DIII-D neutral beam injection systems, as well as for pertinent data acquisition and safety interlocking. Recently, improvements were made to the I and C system. With the replacement of the NB control computers, new signal interfacing was required to accommodate the elimination of physical operator panels, in favor of graphical user interface control pages on computer terminal screens. The program in the mode control (MC) programmable logic controller (PLC), which serves as a logic-processing interface between the NB control computers and system hardware, was modified to improve the availability of NB heating of DIII-D plasmas in the event that one or more individual beam systems suddenly become unavailable while preparing for a tokamak experimental shot sequences. An upgraded computer platform was adopted for the NB control system operator interface and new graphical user interface pages were developed to more efficiently display system status data. A failure mode of the armor tile infrared thermometers (pyrometers), which serve to terminate beam pulsing if beam shine-through overheats wall thermal shielding inside the DIII-D tokamak, was characterized such that impending failures can be detected and repairs effected to mitigate beam system down-time. The hardware that controls gas flow to the beamline neutralizer cells was upgraded to reduce susceptibility to electromagnetic interference (EMI), and interlocking was provided to terminate beam pulsing in the event of insufficient neutralizer gas flow. Motivation, implementation, and results of these improvements are presented

  10. Differential correction system of laser beam directional dithering based on symmetrical beamsplitter

    Science.gov (United States)

    Hongwei, Yang; Wei, Tao; Xiaoqia, Yin; Hui, Zhao

    2018-02-01

    This paper proposes a differential correction system with a differential optical path and a symmetrical beamsplitter for correcting the directional dithering of the laser beams. This system can split a collimated laser beam into two laser beams with equal and opposite movements. Thus, the positional averages of the two split laser beams remain constant irrespective of the dithering angle. The symmetrical beamsplitter designed based on transfer matrix principle is to balance the optical paths and irradiances of the two laser beams. Experimental results show that the directional dithering is reduced to less than one-pixel value. Finally, two examples show that this system can be widely used in one-dimensional measurement.

  11. Risk-based configuration control

    International Nuclear Information System (INIS)

    Szikszai, T.

    1997-01-01

    The presentation discusses the following issues: The Configuration Control; The Risk-based Configuration Control (during power operation mode, and during shutdown mode). PSA requirements. Use of Risk-based Configuration Control System. Configuration Management (basic elements, benefits, information requirements)

  12. Control and data acquisition of the ITER full-scale ion source for the neutral beam test facility

    Energy Technology Data Exchange (ETDEWEB)

    Luchetta, Adriano, E-mail: adriano.luchetta@igi.cnr.it [Consorzio RFX (CNR, ENEA, INFN, Università di Padova, Acciaierie Venete SpA), Padova (Italy); Manduchi, Gabriele; Taliercio, Cesare [Consorzio RFX (CNR, ENEA, INFN, Università di Padova, Acciaierie Venete SpA), Padova (Italy); Paolucci, Francesco; Sartori, Filippo [Fusion for Energy, Barcelona (Spain); Svensson, Lennart [ITER Organization, Route de Vinon-sur-Verdon, CS 90046 St. Paul Lez Durance (France); Labate, Carmelo Vincenzo [Association ENEA-CREATE, Department of Engineering, University of Naples “Parthenope” (Italy); Breda, Mauro; Capobianco, Roberto; Molon, Federico; Moressa, Modesto; Simionato, Paola; Zampiva, Enrico; Barbato, Paolo; Polato, Sandro [Consorzio RFX (CNR, ENEA, INFN, Università di Padova, Acciaierie Venete SpA), Padova (Italy)

    2015-10-15

    Highlights: • This paper describes the requirements and architecture of the control and data acquisition system of the ITER full-ion source experiment in the neutral beam test facility. • The system architecture integrates various popular software frameworks. • Slow control is based on the EPICS (Experimental Physics and Industrial Control System) framework. • Fast control is based on the MARTe (Multi-threaded Application Real-Time executor) framework. • Data acquisition is based on the MDSplus framework. - Abstract: The neutral beam test facility, which is under construction in Padova, Italy, is developing the ITER full-scale ion source for the ITER heating neutral beam injectors, referred to as the SPIDER experiment, and the full-size prototype injector, referred to as MITICA. The SPIDER control and data acquisition system (CODAS) has been developed and its construction will start in 2014. Slow control and data acquisition will be based on the ITER CODAC core system software suite that has been designed to facilitate the integration of ITER plant systems with CODAC. Fast control and data acquisition will use solutions specific to the test facility, as the corresponding concepts are not ready-to-use in the ITER design. The ITER hardware catalog for fast control has been taken into consideration. The software development will be based on the integration of MDSplus and MARTe, two framework software packages that are well known in the fusion community, targeting data organization and fast real-time control, respectively. The paper revises the system requirements and the system design and shows the results already achieved in terms of system integration. In addition, the paper will report the experience in the usage of different cooperating software frameworks and in the integration of industrial procured plant systems.

  13. Use of the TACL [Thaumaturgic Automated Control Logic] system at CEBAF [Continuous Electron Beam Accelerator Facility] for control of the Cryogenic Test Facility

    International Nuclear Information System (INIS)

    Navarro, E.; Keesee, M.; Bork, R.; Grubb, C.; Lahti, G.; Sage, J.

    1989-01-01

    A logic-based control software system, called Thaumaturgic Automated Control Logic (TACL), is under development at the Continuous Electron Beam Accelerator Facility in Newport News, VA. The first version of the software was placed in service in November, 1987 for control of cryogenics during the first superconducting RF cavity tests at CEBAF. In August, 1988 the control system was installed at the Cryogenic Test Facility (CTF) at CEBAF. CTF generated liquid helium in September, 1988 and is now in full operation for the current round of cavity tests. TACL is providing a powerful and flexible controls environment for the operation of CTF. 3 refs

  14. Prestress Force Identification for Externally Prestressed Concrete Beam Based on Frequency Equation and Measured Frequencies

    Directory of Open Access Journals (Sweden)

    Luning Shi

    2014-01-01

    Full Text Available A prestress force identification method for externally prestressed concrete uniform beam based on the frequency equation and the measured frequencies is developed. For the purpose of the prestress force identification accuracy, we first look for the appropriate method to solve the free vibration equation of externally prestressed concrete beam and then combine the measured frequencies with frequency equation to identify the prestress force. To obtain the exact solution of the free vibration equation of multispan externally prestressed concrete beam, an analytical model of externally prestressed concrete beam is set up based on the Bernoulli-Euler beam theory and the function relation between prestress variation and vibration displacement is built. The multispan externally prestressed concrete beam is taken as the multiple single-span beams which must meet the bending moment and rotation angle boundary conditions, the free vibration equation is solved using sublevel simultaneous method and the semi-analytical solution of the free vibration equation which considered the influence of prestress on section rigidity and beam length is obtained. Taking simply supported concrete beam and two-span concrete beam with external tendons as examples, frequency function curves are obtained with the measured frequencies into it and the prestress force can be identified using the abscissa of the crosspoint of frequency functions. Identification value of the prestress force is in good agreement with the test results. The method can accurately identify prestress force of externally prestressed concrete beam and trace the trend of effective prestress force.

  15. Flexural Test of Fly Ash based Geopolimer Concrete Beams

    Directory of Open Access Journals (Sweden)

    Nindyawati

    2017-01-01

    Full Text Available Fly ash is a by-product from the coal industry, which is widely available in Indonesia. Fly ash contains quite high silicate and alumina. Silica and alumina reacts with alkaline solution to produce alumina silicate gel which binds the aggregate to produce geopolymer concrete. Geopolymer concrete is introduced as an environmental concrete with high compressive strength. The use of geopolymer concrete beams is a solution to reduce the effects of greenhouse gases. This research uses experimental designs. The data are obtained from the testing of 4 pieces of reinforced geopolymer concrete beams and reinforced ordinary concrete beams with a / d of 1.11 and 2.24. The results are obtained from the maximum load that can be accepted by the beam. The results of this study are: (1 Geopolymer concrete cylinder has 26.78% higher compressive strength than ordinary concrete cylinders (2 Ordinary concrete beams can withstand 34.8% load higher compared to the geopolymer concrete beam (3 Reinforced ordinary concrete beams experience bending shear collapse while reinforced geopolymer concrete beam experience pure bending collapse.

  16. Polystyrene as a zwitter resist in electron beam lithography based ...

    Indian Academy of Sciences (India)

    The resist action of polystyrene (w, 2,600,000) towards electroless deposition of gold on Si(100) surface following cross-linking by exposing to a 10 kV electron beam, has been investigated employing a scanning electron microscope equipped with electron beam lithography tool. With a low dose of electrons (21 C/cm2), ...

  17. ECR ion source based low energy ion beam facility

    Indian Academy of Sciences (India)

    Mass analyzed highly charged ion beams of energy ranging from a few keV to a few MeV plays an important role in various aspects of research in modern physics. In this paper a unique low energy ion beam facility (LEIBF) set up at Nuclear Science Centre (NSC) for providing low and medium energy multiply charged ion ...

  18. ECR ion source based low energy ion beam facility

    Indian Academy of Sciences (India)

    Abstract. Mass analyzed highly charged ion beams of energy ranging from a few keV to a few. MeV plays an important role in various aspects of research in modern physics. In this paper a unique low energy ion beam facility (LEIBF) set up at Nuclear Science Centre (NSC) for providing low and medium energy multiply ...

  19. Electron beam deflection control system of a welding and surface modification installation

    Science.gov (United States)

    Koleva, E.; Dzharov, V.; Gerasimov, V.; Tsvetkov, K.; Mladenov, G.

    2018-03-01

    In the present work, we examined the patterns of the electron beam motion when controlling the transverse with respect to the axis of the beam homogeneous magnetic field created by the coils of the deflection system the electron gun. During electron beam processes, the beam motion is determined the process type (welding, surface modification, etc.), the technological mode, the design dimensions of the electron gun and the shape of the processed samples. The electron beam motion is defined by the cumulative action of two cosine-like control signals generated by a functional generator. The signal control is related to changing the amplitudes, frequencies and phases (phase differences) of the generated voltages. We realized the motion control by applying a graphical user interface developed by us and an Arduino Uno programmable microcontroller. The signals generated were calibrated using experimental data from the available functional generator. The free and precise motion on arbitrary trajectories determines the possible applications of an electron beam process to carrying out various scientific research tasks in material processing.

  20. Two-color beam generation based on wakefield excitation

    Directory of Open Access Journals (Sweden)

    S. Bettoni

    2016-05-01

    Full Text Available Several beam manipulation methods have been studied and experimentally tested to generate two-color photon beams in free electron laser facilities to accommodate the user requests. We propose to use the interaction of the beam with an oscillating longitudinal wakefield source to obtain a suitable electron beam structure. The bunch generates two subpulses with different energies and delayed in time passing through a magnetic chicane after its longitudinal phase space has been modulated by the wakefield source. According to this approach the power of the emitted radiation is not degraded compared to the monochromatic beam, and the setup in the machine is quite simple because the bunch is manipulated only in the high energy section, where it is more rigid. We present the design applied to SwissFEL. We identified the parameters and the corresponding range of tunability of the time and energy separation among the two subbunches.

  1. A proportional-plus-integral controller for a particle beam weapon

    Science.gov (United States)

    Moose, W. J.

    1984-12-01

    The goal of this thesis is to design a proportional-plus-integral (PI) controller, for use with the Meer filter, to control a particle beam weapon. The device used to measure the beam produces a low signal rate, the Meer filter is used to produce an estimate of the beam position. A type-1, proportional-plus-integral controller is designed using LOG assumptions and dynamic programming to solve the cost function. A sensitivity analysis is performed to determine the system sensitivity to different parameters. A performance analysis is also performed to demonstrate the system robustness to unmodelled errors. The results of these analyses are compared to a type-0, proportional gain controller. In addition the PI controllers ability to regulate to a non-zero setpoint is demonstrated.

  2. Model-based expert systems for linac computer controls

    International Nuclear Information System (INIS)

    Lee, M.J.

    1988-09-01

    The use of machine modeling and beam simulation programs for the control of accelerator operation has become standard practice. The success of a model-based control operation depends on how the parameter to be controlled is measured, how the measured data is analyzed, how the result of the analysis is interpreted, and how a solution is implemented. There is considerable interest in applying expert systems technology that can automate all of these processes. The design of an expert system to control the beam trajectory in linear accelerators will be discussed as an illustration of this approach. 4 figs., 1 tab

  3. Developing an expert system to control a beam line at the Los Alamos Meson Physics Facility

    International Nuclear Information System (INIS)

    Clearwater, S.H.; Papcun, G.; Clark, D.A.

    1985-01-01

    High energy particle experiments require an accelerator as a source of high energy particles. To increase the productivity of an accelerator facility, we wish to develop an expert system to control beam lines. Expert Systems are a branch of Artificial Intelligence where a computer program performs tasks requiring human expertise. Unlike most expert systems we have a physical model underlying our beam line and this model can be used with the expert system to improve performance. The development of the expert system will lead to an increased understanding of the beam line as well as the possibility of state-of-the-art expert system building

  4. Beam Dynamics and Pulse Duration Control During Final Beam Bunching in Driver System for Heavy Ion Inertial Fusion

    CERN Document Server

    Kikuchi, Takashi; Katayama, Takeshi; Kawata, Shigeo; Nakajima, Mitsuo; Someya, Tetsuo

    2005-01-01

    Beam dynamics is investigated by multi-particle simulations during a final beam bunching in a driver system for heavy ion inertial fusion (HIF). The longitudinal bunch compression causes the beam instability induced by the strong space charge effect. The multi-particle simulation can indicate the emittance growth due to the longitudinal bunch compression. Dependence in the beam pulse duration is also investigated for effective pellet implosion in HIF. Not only the spatial nonuniformity of the beam illumination, but also the errors of the beam pulse duration cause changes of implosion dynamics. The allowable regime of the beam pulse duration for the effective fusion output becomes narrow with decreasing the input beam energy. The voltage accuracy requirement at the beam velocity modulator is also estimated for the final beam bunching. It is estimated that the integrated voltage error is allowable as a few percent.

  5. Broadband and high-efficiency vortex beam generator based on a hybrid helix array.

    Science.gov (United States)

    Fang, Chaoqun; Wu, Chao; Gong, Zhijie; Zhao, Song; Sun, Anqi; Wei, Zeyong; Li, Hongqiang

    2018-04-01

    The vortex beam which carries the orbital angular momentum has versatile applications, such as high-resolution imaging, optical communications, and particle manipulation. Generating vortex beams with the Pancharatnam-Berry (PB) phase has drawn considerable attention for its unique spin-to-orbital conversion features. Despite the PB phase being frequency independent, an optical element with broadband high-efficiency circular polarization conversion feature is still needed for the broadband high-efficiency vortex beam generation. In this work, a broadband and high-efficiency vortex beam generator based on the PB phase is built with a hybrid helix array. Such devices can generate vortex beams with arbitrary topological charge. Moreover, vortex beams with opposite topological charge can be generated with an opposite handedness incident beam that propagates backward. The measured efficiency of our device is above 65% for a wide frequency range, with the relative bandwidth of 46.5%.

  6. Development of a Laser-based Emittance Monitor for Negative Hydrogen Beams

    CERN Document Server

    AUTHOR|(CDS)2078368; Schmauss, Bernhard; Gibson, Stephen; Boorman, Gary; Bosco, Alessio

    High energy particle accelerators are designed to collide charged particle beams and thus study the collision products. Maximising the collision rate, to generate sufficient statistics for precise measurements of rare processes, is one of the key parameters for optimising the overall collider performance. The CERN Large Hadron Collider (LHC) Injectors Upgrade (LIU) includes the construction of LINAC4, a completely new machine working as a first linear acceleration stage for the LHC beam. By accelerating a negative hydrogen beam (H-) instead of protons, it aims to double the beam brightness via a more efficient transfer to the first circular accelerator and subsequently boost the LHC collision rate. To achieve this, a precise knowledge of the transverse beam characteristics in terms of beam emittance is essential. This thesis work covers the development of a laser-based monitor meant to measure non-destructively the LINAC4 beam transverse profile and emittance. This included the implementation of dif...

  7. A laser-based beam profile monitor for the SLC/SLD interaction region

    International Nuclear Information System (INIS)

    Alley, R.; Arnett, D.; Bong, E.; Colocho, W.; Frisch, J.; Horton-Smith, S.; Inman, W.; Jobe, K.; Kotseroglou, T.; McCormick, D.; Nelson, J.; Scheeff, M.; Wagner, S.; Ross, M.C.

    1996-01-01

    Beam size estimates made using beam-beam deflections are used for optimization of the Stanford linear collider (SLC) electron-positron beam sizes. Typical beam sizes and intensities expected for 1996 operations are 2.1 x 0.6 μm (x, y) at 4.0.10 10 particles per pulse. Conventional profile monitors, such as scanning wires, fail at charge densities well below this. The laser-based profile monitor uses a finely-focused 350-nm wavelength tripled YLF laser pulse that traverses the particle beam path about 29 cm away from the e + /e - IP. Compton scattered photons and degraded e + /e - are detected as the beam is steered across the laser pulse. The laser pulse has a transverse size of 380 nm and a Rayleigh range of about 5 μm. (orig.)

  8. Development and Optimisation of the SPS and LHC beam diagnostics based on Synchrotron Radiation monitors

    CERN Document Server

    AUTHOR|(CDS)2081364; Roncarolo, Federico

    Measuring the beam transverse emittance is fundamental in every accelerator, in particular for colliders, where its precise determination is essential to maximize the luminosity and thus the performance of the colliding beams.
 Synchrotron Radiation (SR) is a versatile tool for non-destructive beam diagnostics, since its characteristics are closely related to those of the source beam. At CERN, being the only available diagnostics at high beam intensity and energy, SR monitors are exploited as the proton beam size monitor of the two higher energy machines, the Super Proton Synchrotron (SPS) and the Large Hadron Collider (LHC). The thesis work documented in this report focused on the design, development, characterization and optimization of these beam size monitors. Such studies were based on a comprehensive set of theoretical calculations, numerical simulations and experiments. A powerful simulation tool has been developed combining conventional softwares for SR simulation and optics design, thus allowing t...

  9. Quality control methodology and implementation of X-radiation standards beams, mammography level, following the standard IEC 61267

    International Nuclear Information System (INIS)

    Correa, Eduardo de Lima

    2010-01-01

    In this work it was developed and applied a quality control program of the X radiation system (160 kV, constant potential, target of tungsten) of the Calibration Laboratory of IPEN(LCI) in the energy range relative to mammography beams (from 25 kV to 35 kV). The X radiation standards beams, level mammography, using molybdenum and aluminum as additional filtration, were established after the application of this quality control program following national and international recommendations. The reference ionization chamber has traceability to PTB and was regularly submitted to quality control tests for evaluation and analysis of its performance. The radiation qualities emerging from the X-radiation assembly (RQR-M), based on a phantom made up of an aluminum added filter (RQA-M), narrow beam condition (RQN-M) and broad beam condition (RQB-M), following the recommendations of the international standard IEC 61267 (2005) and the IAEA code of practice, TRS 457 (2007) were established. For the implantation of RQN-M and RQB-M radiation qualities, two mammography phantoms were developed. The half-value layers found are those presented by the German primary laboratory PTB, and varied from 0.35 to 1.21 mm Al. The air kerma rates were obtained for all the 15 implanted qualities. (author)

  10. Electron beam technology for multipollutant emissions control from heavy fuel oil-fired boiler.

    Science.gov (United States)

    Chmielewski, Andrzej G; Ostapczuk, Anna; Licki, Janusz

    2010-08-01

    The electron beam treatment technology for purification of exhaust gases from the burning of heavy fuel oil (HFO) mazout with sulfur content approximately 3 wt % was tested at the Institute of Nuclear Chemistry and Technology laboratory plant. The parametric study was conducted to determine the sulfur dioxide (SO2), oxides of nitrogen (NO(x)), and polycyclic aromatic hydrocarbon (PAH) removal efficiency as a function of temperature and humidity of irradiated gases, absorbed irradiation dose, and ammonia stoichiometry process parameters. In the test performed under optimal conditions with an irradiation dose of 12.4 kGy, simultaneous removal efficiencies of approximately 98% for SO2, and 80% for NO(x) were recorded. The simultaneous decrease of PAH and one-ringed aromatic hydrocarbon (benzene, toluene, and xylenes [BTX]) concentrations was observed in the irradiated flue gas. Overall removal efficiencies of approximately 42% for PAHs and 86% for BTXs were achieved with an irradiation dose 5.3 kGy. The decomposition ratio of these compounds increased with an increase of absorbed dose. The decrease of PAH and BTX concentrations was followed by the increase of oxygen-containing aromatic hydrocarbon concentrations. The PAH and BTX decomposition process was initialized through the reaction with hydroxyl radicals that formed in the electron beam irradiated flue gas. Their decomposition process is based on similar principles as the primary reaction concerning SO2 and NO(x) removal; that is, free radicals attack organic compound chains or rings, causing volatile organic compound decomposition. Thus, the electron beam flue gas treatment (EBFGT) technology ensures simultaneous removal of acid (SO2 and NO(x)) and organic (PAH and BTX) pollutants from flue gas emitted from burning of HFO. This technology is a multipollutant emission control technology that can be applied for treatment of flue gas emitted from coal-, lignite-, and HFO-fired boilers. Other thermal processes such

  11. Quality control of radiotherapy centres in the Slovak Republic: a dosimetry intercomparison of photon and electron beams under reference conditions

    International Nuclear Information System (INIS)

    Gomola, I.; Kralik, G.; Laginova, V.; Van Dam, J.

    2001-01-01

    The aim of this paper is a dosimetry intercomparison of photon and electron beams under reference conditions as well as quality control of radiotherapy centres in the Slovak Republic. The results obtained in the first check shows that only about 60% of beams are within the acceptance limit. The reasons of discrepancies were traced, in some cases by an on site visit of experts from the NRC, and unacceptable deviations were corrected. The results clearly demonstrate the usefulness of the external dosimetry checks performed with the mailed thermoluminescent dosimeters. Standard deviation of the distribution of the results decreased from SD=4.3% to SD=I.8% for checked photon beams and from SD=8.6% to SD=2.4% for electron beams, respectively, at the end of the project. The dosimetry audits which are performed in regular intervals significantly decreasing a possibility of mistreatment (under-dosage or over-dosage ) of patients due to wrong calibration of radiation therapy beams. In order to keep the reached level of dosimetry precision, it is necessary to establish the external audit in radiotherapy at the national level based on postal TLD dosimetry by transferring the know-how from the international program on quality assurance in radiotherapy dosimetry with the assistance of the IAEA. (authors)

  12. Mechanisms and control of beam halo formation in intense microwave sources and accelerators

    Science.gov (United States)

    Chen, C.; Pakter, R.

    2000-05-01

    Halo formation and control in space-charge-dominated electron and ion beams are investigated in parameter regimes relevant to the development of high-power microwave (HPM) sources and high-intensity electron and ion linear accelerators. In particular, a mechanism for electron beam halo formation is identified in high-power periodic permanent magnet (PPM) focusing klystron amplifiers. It is found in self-consistent simulations that large-amplitude current oscillations induce mismatched beam envelope oscillations and electron beam halo formation. Qualitative agreement is found between simulations and the 50 MW 11.4 GHz PPM focusing klystron experiment at Stanford Linear Accelerator Center (SLAC) (D. Sprehn, G. Caryotakis, E. Jongewaard, and R. M. Phillips, "Periodic permanent magnetic development for linear collider X-band klystrons," Proceedings of the XIXth International Linac Conference, Argonne National Laboratory Report ANL-98/28, 1998, p. 689). Moreover, a new class of cold-fluid corkscrewing elliptic beam equilibria is discovered for ultrahigh-brightness, space-charge dominated electron or ion beam propagation through a linear focusing channel consisting of uniform solenoidal magnetic focusing fields, periodic solenoidal magnetic focusing fields, and/or alternating-gradient quadrupole magnetic focusing fields in an arbitrary arrangement including field tapering. As an important application of such new cold-fluid corkscrewing elliptic beam equilibria, a technique is developed and demonstrated for controlling of halo formation and beam hollowing in a rms-matched ultrahigh-brightness ion beam as it is injected from an axisymmetric Pierce diode into an alternating-gradient magnetic quadrupole focusing channel.

  13. Automatically controlled correlation spectrometer with a bounded positron beam

    International Nuclear Information System (INIS)

    Grone, R.

    1991-01-01

    The spectrometer consists of a frame which carries a fixed arm with collimating slits and a pair of scintillator units positioned against each other, and a movable arm which moves in the horizontal plane and also holds collimating slits and two scintillator units positioned against each other. In the centre of the frame is a shielding cover with a chamber housing a slidable positron source. The end of the cover is fitted with a replaceable diaphragm against which a sample holder is positioned. The chamber with a bounded positron beam can be employed to measure a sample at preselected sites and thus gain information concerning various parts of the sample surface and its inhomogeneity. (M.D.). 3 figs

  14. The Tenability of Vibration Parameters of a Sandwich Beam Featuring Controllable Core: Experimental Investigation

    Directory of Open Access Journals (Sweden)

    Shreedhar Kolekar

    2017-01-01

    Full Text Available This study presents experimental results of the vibration parameters of a sandwich beam featuring magnetorheological (MR fluid as core material. For simplicity, the sandwich beam is considered as a single-degree-of-freedom (SDOF system and the governing equation is derived in time and frequency domains. Then, from the governing equation, the vibration parameters which can be controllable by external stimuli are defined or obtained. These are the field-dependent natural frequency, damping factor, loss factor, and quality factor of the sandwich beam. Subsequently, a sandwich beam incorporating with controllable MR fluid core is fabricated and tested to evaluate the vibration parameters. MR fluid is prepared using the engine oil, iron particles, and grease as an additive and it is filled into the void zone (core of the sandwich beam. The fabricated beam is then tested at four different conditions and the vibration parameters are numerically identified at each test. It is shown that both the natural frequency and damping property can be tuned by controlling the intensity of the magnetic field applied to MR fluid domain.

  15. Optimal shape control of piezolaminated beams with different boundary condition and loading using genetic algorithm

    Science.gov (United States)

    Bendine, Kouider; Wankhade, Rajan L.

    2017-12-01

    Piezoelectric actuators are effectively used to control the response of light weight structures in shape, vibration and buckling. Optimization for the shape control of piezoelectric beam is the recent challenge which requires proper numerical technique to perform. The shape control of a composite beam using surface-bounded piezoelectric actuators has been investigated in the present work. The mathematical model is developed using two-node Timoshenko beam element coupling with the theory of linear piezoelectricity. First-order shear deformation theory is employed in the formulation to consider the effect of shear. In the analysis, the effect of the actuators position for different set of boundary conditions is investigated. For different boundary conditions which include clamped-free-, clamped-clamped- and simply supported beam, optimisation of piezoelectric patch location is investigated. Moreover, a genetic algorithm is adopted and implemented to optimize the required voltage to maintain the desired shape of the beam. This optimization technique is applied to different cases of composite beams with varying the boundary condition.

  16. A nonlinear OPC technique for laser beam control in turbulent atmosphere

    Science.gov (United States)

    Markov, V.; Khizhnyak, A.; Sprangle, P.; Ting, A.; DeSandre, L.; Hafizi, B.

    2013-05-01

    A viable beam control technique is critical for effective laser beam transmission through turbulent atmosphere. Most of the established approaches require information on the impact of perturbations on wavefront propagated waves. Such information can be acquired by measuring the characteristics of the target-scattered light arriving from a small, preferably diffraction-limited, beacon. This paper discusses an innovative beam control approach that can support formation of a tight laser beacon in deep turbulence conditions. The technique employs Brillouin enhanced fourwave mixing (BEFWM) to generate a localized beacon spot on a remote image-resolved target. Formation of the tight beacon doesn't require a wavefront sensor, AO system, or predictive feedback algorithm. Unlike conventional adaptive optics methods which allow wavefront conjugation, the proposed total field conjugation technique is critical for beam control in the presence of strong turbulence and can be achieved by using this non-linear BEFWM technique. The phase information retrieved from the established beacon beam can then be used in conjunction with an AO system to propagate laser beams in deep turbulence.

  17. LabVIEW control software for scanning micro-beam X-ray fluorescence spectrometer.

    Science.gov (United States)

    Wrobel, Pawel; Czyzycki, Mateusz; Furman, Leszek; Kolasinski, Krzysztof; Lankosz, Marek; Mrenca, Alina; Samek, Lucyna; Wegrzynek, Dariusz

    2012-05-15

    Confocal micro-beam X-ray fluorescence microscope was constructed. The system was assembled from commercially available components - a low power X-ray tube source, polycapillary X-ray optics and silicon drift detector - controlled by an in-house developed LabVIEW software. A video camera coupled to optical microscope was utilized to display the area excited by X-ray beam. The camera image calibration and scan area definition software were also based entirely on LabVIEW code. Presently, the main area of application of the newly constructed spectrometer is 2-dimensional mapping of element distribution in environmental, biological and geological samples with micrometer spatial resolution. The hardware and the developed software can already handle volumetric 3-D confocal scans. In this work, a front panel graphical user interface as well as communication protocols between hardware components were described. Two applications of the spectrometer, to homogeneity testing of titanium layers and to imaging of various types of grains in air particulate matter collected on membrane filters, were presented. Copyright © 2012 Elsevier B.V. All rights reserved.

  18. A beam intensity profile monitor based on secondary electron emission

    International Nuclear Information System (INIS)

    Berdoz, A.R.; Birchall, J.; Campbell, J.R.; Davis, C.A.; Davison, N.E.; Mosscrop, D.R.; Page, S.A.; Ramsay, W.D.; Sekulovich, A.M.; Van Oers, W.T.H.; MIschke, R.E.

    1991-03-01

    Two dual function intensity profile monitors have been designed for a measurement of parity violation in antiproton-proton scattering at about 230 MeV using longitudinally polarized protons. Each device contains a set of split secondary electron emission (SEM) foils to determine the median of the beam current distribution (in x and y). The split foils, coupled through servoamplifiers and operational amplifiers to upstream air core steering magnets, have demonstrated the ability to hold the beam position stable to within ± 3 μm after one hour of data taking with a 100 nA, 15 mm FWHM Gaussian beam. (Author) 16 refs., 10 figs., tab

  19. Reconstruction of laser beam wavefronts based on mode analysis

    CSIR Research Space (South Africa)

    Schulze, C

    2013-07-01

    Full Text Available . Experimental Setup To measure the influence of defined Zernike aberra- tions on a laser beam, we used an experimental setup as outlined in Fig. 3. The beam of a helium–neon laser (10 mW power, 633 nm wavelength) was expanded and collimated [ f �L 1 � � 15 mm, f.... Insets depict the shapes of the corresponding aberrations. Fig. 3. Schematic of the experimental setup to modally decom- pose differently aberrated Gaussian beams. He–Ne, helium–neon laser; L 1–5 , lenses; M, mirror; SLM 1;2, spatial light modulator...

  20. Terahertz beam switching by electrical control of graphene-enabled tunable metasurface.

    Science.gov (United States)

    Zhang, Yin; Feng, Yijun; Zhao, Junming; Jiang, Tian; Zhu, Bo

    2017-10-26

    Controlling the terahertz wave, especially the dynamical and full control of terahertz wavefront, is highly demanded due to the increasing development of practical devices and application systems. Recently considerable efforts have been made to fill the 'terahertz gap' with the help of artificial metamaterial or metasurface incorporated with graphene material. Here, we propose a scheme to design tunable metasurface consisting of metallic patch array on a grounded polymer substrate embedded with graphene layers to electrically control the electromagnetic beam reflection at terahertz frequency. By adjusting geometric dimension of the patch elements, 360 degree reflection phase range may be achieved, thus abrupt phase shifts can be introduced along the metasurface for tailoring the reflected wavefront. Moreover, the reflective phase gradient over the metasurface can be switched between 90 and 360 degree by controlling the Fermi energy of the embedded graphene through voltage biasing, hence dynamically switching the reflective beam directions. Numerical simulations demonstrate that either single beam or dual beam dynamically switching between normal and oblique reflection angles can be well attained at working frequency. The proposed approach will bring much freedom in the design of beam manipulation devices and may be applied to terahertz radiation control.

  1. Experimental demonstration of Generalized Phase Contrast based Gaussian beam-shaper

    DEFF Research Database (Denmark)

    Tauro, Sandeep; Bañas, Andrew Rafael; Palima, Darwin

    2011-01-01

    -cost binary-phase optics fabricated using photolithography and chemical etching techniques can replace the SLM in static and high power beam shaping applications. The design parameters for the binary-phase elements of the module are chosen according to the results of our previously conducted analysis......We report the first experimental demonstration of Gaussian beam-shaping based on the Generalized Phase Contrast (GPC) approach. We show that, when using a dynamic spatial light modulator (SLM), this approach can rapidly generate arbitrarily shaped beams. Moreover, we demonstrate that low...... and numerical demonstrations [Opt. Express 15, 11971 (2007)]. Beams with a variety of cross-sections such as circular, rectangular and square, with near flat-top intensity distributions are demonstrated. GPC-based beam shaping is inherently speckle-free and the shaped beams maintain a flat output phase. The non...

  2. A fast beam hardening correction method incorporated in a filtered back-projection based MAP algorithm

    Science.gov (United States)

    Luo, Shouhua; Wu, Huazhen; Sun, Yi; Li, Jing; Li, Guang; Gu, Ning

    2017-03-01

    The beam hardening effect can induce strong artifacts in CT images, which result in severely deteriorated image quality with incorrect intensities (CT numbers). This paper develops an effective and efficient beam hardening correction algorithm incorporated in a filtered back-projection based maximum a posteriori (BHC-FMAP). In the proposed algorithm, the beam hardening effect is modeled and incorporated into the forward-projection of the MAP to suppress beam hardening induced artifacts, and the image update process is performed by Feldkamp-Davis-Kress method based back-projection to speed up the convergence. The proposed BHC-FMAP approach does not require information about the beam spectrum or the material properties, or any additional segmentation operation. The proposed method was qualitatively and quantitatively evaluated using both phantom and animal projection data. The experimental results demonstrate that the BHC-FMAP method can efficiently provide a good correction of beam hardening induced artefacts.

  3. Physical mechanism of beam splitting based on reflective embedded double-layer grating

    Science.gov (United States)

    Wang, Bo; Li, Hongtao; Shu, Wenhao; Li, Wenhua; Chen, Li; Lei, Liang; Zhou, Jinyun

    2016-12-01

    It is not easy to achieve high performance for conventional beam splitters, such as high efficiency, good uniformity, polarization-independence, and wide bandwidth. A reflective embedded double-layer grating is described for beam splitting. With optimized grating profiles, the novel beam splitter can diffract both TE and TM polarizations into two orders with high performance. For the easy production, the fabrication tolerance is investigated and given. Most importantly, efficiencies more than 45% can be split into two orders within the wide bandwidth of 1412-1647 nm for TE polarization. The beam splitter based on multilayer coatings is sensitive to the incident angle and wavelength. And the bandwidth needs to be improved for the beam splitter based on simple grating. The design is of benefit for the performance improvement of the beam splitter by new grating configuration compared with the conventional simple grating.

  4. Study of biomaterials by ion-beam based methods

    International Nuclear Information System (INIS)

    Racolta, Petru; Craciun, Liviu; Cincu, Emanuela; Voiculescu, Dana; Muresan, Ofelia; Serban, Alin; Filip, Andrei Ilie; Bunea, Danil; Antoniac, Vasile; Tudor, Tiberiu Laurian; Visan, Teodor; Visan, Sanda; Ibris, Neluta

    2002-01-01

    The extension lifetime of prosthetic devices, dental materials and orthodontic devices is one main goal of the international medical supply community. In the frame of an interdisciplinary national project, IFIN-HH has started experimentation on some alternative procedures to study the wear/corrosion phenomena of biological materials by using ion-beam based techniques. Since joint prostheses are mechanical bearings there are concerns over friction and wear just as there are with any bearing. These concerns date back to the early introduction of total hip prostheses and were shown to be justified by the early failures due to wear. Subsequently, changes in materials and designs reduced the incidence of wear failure to a low level at which failures due to other mechanisms became dominant. Interest turned to preventing femoral component fracture, reducing the rates of infection, and reducing the rates of loosening. Attention to wear as a mechanism of failure has recently increased. The failure rate for joint replacement at the hip or knee has been progressively reduced. The biologic effects of wear debris have been recognized; wearing out of the prosthesis is no longer a prerequisite for an adverse outcome. There is an active search for new materials with increased wear resistance. In the case of metallic component from hip, knee prostheses and dental alloys, we present the optimum nuclear reactions according with the main parameters of our U-120 Cyclotron (p, d, E max = 13 MeV and α particle, E max = 26 MeV). In the case of polymers, one of an articulating couple of the prosthetic devices, direct activation causes severe changes in its surface morphology and its structure (formation of defects and free radicals). We have developed an indirect activation mode using the principle of recoil ion implantation, applied to 56 Co radioactive ions generated by proton particle beams on a Fe target (thickness ∼ 10 mm). A thin target of elementary composition A is bombarded by

  5. Design of Data Acquisition and Control System for Indian Test Facility of Diagnostics Neutral Beam

    International Nuclear Information System (INIS)

    Soni, Jignesh; Tyagi, Himanshu; Yadav, Ratnakar; Rotti, Chandramouli; Bandyopadhyay, Mainak; Bansal, Gourab; Gahluat, Agrajit; Sudhir, Dass; Joshi, Jaydeep; Prasad, Rambilas; Pandya, Kaushal; Shah, Sejal; Parmar, Deepak; Chakraborty, Arun

    2015-01-01

    Highlights: • More than 900 channels Data Acquisition and Control System. • INTF DACS has been designed based on ITER-PCDH guidelines. • Separate Interlock and Safety system designed based on IEC 61508 standard. • Hardware selected from ITER slow controller and fast controller catalog. • Software framework based on ITER CODAC Core System and LabVIEW software. - Abstract: The Indian Test Facility (INTF) – a negative hydrogen ion based 100 kV, 60 A, 5 Hz modulated NBI system having 3 s ON/20 s OFF duty cycle. Prime objective of the facility is to install a full-scale test bed for the qualification of all Diagnostic Neutral Beam (DNB) parameters, prior to installation in ITER. The automated and safe operation of the INTF will require a reliable and rugged instrumentation and control system which provide control, data acquisition (DAQ), interlock and safety functions, referred as INTF-DACS. The INTF-DACS has been decided to be design based on the ITER CODAC architecture and ITER-PCDH guidelines since the technical understanding of CODAC technology gained from this will later be helpful in development of plant system I&C for DNB. For complete operation of the INTF, approximately 900 numbers of signals are required to be superintending by the DACS. In INTF conventional control loop time required is within the range of 5–100 ms and for DAQ except high-end diagnostics, required sampling rates in range of 5 sample per second (Sps) to 10 kSps; to fulfill these requirements hardware components have been selected from the ITER slow and fast controller catalogs. For high-end diagnostics required sampling rates up to 100 MSps normally in case of certain events, therefore event and burst based DAQ hardware has been finalized. Combined use of CODAC core software (CCS) and NI-LabVIEW has been finalized due to the fact that full required DAQ support is not available in present version of CCS. Interlock system for investment protection of facility and Safety system for

  6. Design of Data Acquisition and Control System for Indian Test Facility of Diagnostics Neutral Beam

    Energy Technology Data Exchange (ETDEWEB)

    Soni, Jignesh, E-mail: jsoni@ipr.res.in [Institute for Plasma Research, Bhat, Gandhinagar 382 428, Gujarat (India); Tyagi, Himanshu; Yadav, Ratnakar; Rotti, Chandramouli; Bandyopadhyay, Mainak [ITER-India, Institute for Plasma Research, Gandhinagar 380 025, Gujarat (India); Bansal, Gourab; Gahluat, Agrajit [Institute for Plasma Research, Bhat, Gandhinagar 382 428, Gujarat (India); Sudhir, Dass; Joshi, Jaydeep; Prasad, Rambilas [ITER-India, Institute for Plasma Research, Gandhinagar 380 025, Gujarat (India); Pandya, Kaushal [Institute for Plasma Research, Bhat, Gandhinagar 382 428, Gujarat (India); Shah, Sejal; Parmar, Deepak [ITER-India, Institute for Plasma Research, Gandhinagar 380 025, Gujarat (India); Chakraborty, Arun [Institute for Plasma Research, Bhat, Gandhinagar 382 428, Gujarat (India)

    2015-10-15

    Highlights: • More than 900 channels Data Acquisition and Control System. • INTF DACS has been designed based on ITER-PCDH guidelines. • Separate Interlock and Safety system designed based on IEC 61508 standard. • Hardware selected from ITER slow controller and fast controller catalog. • Software framework based on ITER CODAC Core System and LabVIEW software. - Abstract: The Indian Test Facility (INTF) – a negative hydrogen ion based 100 kV, 60 A, 5 Hz modulated NBI system having 3 s ON/20 s OFF duty cycle. Prime objective of the facility is to install a full-scale test bed for the qualification of all Diagnostic Neutral Beam (DNB) parameters, prior to installation in ITER. The automated and safe operation of the INTF will require a reliable and rugged instrumentation and control system which provide control, data acquisition (DAQ), interlock and safety functions, referred as INTF-DACS. The INTF-DACS has been decided to be design based on the ITER CODAC architecture and ITER-PCDH guidelines since the technical understanding of CODAC technology gained from this will later be helpful in development of plant system I&C for DNB. For complete operation of the INTF, approximately 900 numbers of signals are required to be superintending by the DACS. In INTF conventional control loop time required is within the range of 5–100 ms and for DAQ except high-end diagnostics, required sampling rates in range of 5 sample per second (Sps) to 10 kSps; to fulfill these requirements hardware components have been selected from the ITER slow and fast controller catalogs. For high-end diagnostics required sampling rates up to 100 MSps normally in case of certain events, therefore event and burst based DAQ hardware has been finalized. Combined use of CODAC core software (CCS) and NI-LabVIEW has been finalized due to the fact that full required DAQ support is not available in present version of CCS. Interlock system for investment protection of facility and Safety system for

  7. Synthesis of dynamic phase profile by the correlation technique for spatial control of optical beams in multiplexing and switching

    Science.gov (United States)

    Bugaychuk, Svitlana A.; Gnatovskyy, Vladimir O.; Sidorenko, Andrey V.; Pryadko, Igor I.; Negriyko, Anatoliy M.

    2015-11-01

    New approach for the correlation technique, which is based on multiple periodic structures to create a controllable angular spectrum, is proposed and investigated both theoretically and experimentally. The transformation of an initial laser beam occurs due to the actions of consecutive phase periodic structures, which may differ by their parameters. Then, after the Fourier transformation of a complex diffraction field, the output diffraction orders will be changed both by their intensities and by their spatial position. The controllable change of output angular spectrum is carried out by a simple control of the parameters of the periodic structures. We investigate several simple examples of such management.

  8. Negative-ion-based neutral beams for fusion

    International Nuclear Information System (INIS)

    Cooper, W.S.; Anderson, O.A.; Chan, C.F.

    1987-10-01

    To maximize the usefulness of an engineering test reactor (e.g., ITER, TIBER), it is highly desirable that it operate under steady-state conditions. The most attractive option for maintaining the circulating current needed in the center of the plasma is the injection of powerful beams of neutral deuterium atoms. The beam simultaneously heats the plasma. At the energies required, in excess of 500 keV, such beams can be made by accelerating D - ions and then removing the electron. Sources are being developed that generate the D - ions in the volume of a specially constructed plasma discharge, without the addition of cesium. These sources must operate with minimum gas flow, to avoid stripping the D - beam, and with minimum electron output. We are designing at LBL highly efficient electrostatic accelerators that combine electric strong-focusing with dc acceleration and offer the possibility of varying the beam energy at constant current while minimizing breakdown. Some form of rf acceleration may also be required. To minimize irradiation of the ion sources and accelerators, the D - beam can be transported through a maze in the neutron shielding. The D - ions can be converted to neutrals in a gas or plasma target, but advances in laser and mirror technology may make possible very efficient photodetachment systems by the time an ETR becomes operational. 9 refs., 4 figs

  9. 100-watt fiber-based green laser with near diffraction-limited beam quality

    Science.gov (United States)

    Hu, Dan; Eisenberg, Eric; Brar, Khush; Yilmaz, Tolga; Honea, Eric

    2010-02-01

    An air-cooled, light-weight, fiber-based, high power green laser has been prototyped. The system consists of an all-fibercoupled IR pump laser at 1064 nm and a frequency-conversion module in a compact and flexible configuration. The IR laser operates in QCW mode, with 10 MHz pulse repetition frequency and 3-5 ns pulse width, to generate sufficient peak power for frequency doubling in the converter module. The IR laser can produce more than 200 W in a linearlypolarized diffraction-limited output beam with high spectral brightness for frequency conversion. The converter module has an input telescope and an oven with a nonlinear crystal to efficiently convert the 1064-nm IR fiber laser output to 532-nm green output. The IR laser and conversion module are connected via a stainless-steel protected delivery fiber for optical beam delivery and an electrical cable harness for electrical power delivery and system control. The beam quality of the 532 nm output remains near diffraction-limited, with M2green laser sources are expected to enable various scientific, defense and industrial applications.

  10. Beam transient analyses of Accelerator Driven Subcritical Reactors based on neutron transport method

    Energy Technology Data Exchange (ETDEWEB)

    He, Mingtao; Wu, Hongchun [School of Nuclear Science and Technology, Xi’an Jiaotong University, Xi’an 710049, Shaanxi (China); Zheng, Youqi, E-mail: yqzheng@mail.xjtu.edu.cn [School of Nuclear Science and Technology, Xi’an Jiaotong University, Xi’an 710049, Shaanxi (China); Wang, Kunpeng [Nuclear and Radiation Safety Center, PO Box 8088, Beijing 100082 (China); Li, Xunzhao; Zhou, Shengcheng [School of Nuclear Science and Technology, Xi’an Jiaotong University, Xi’an 710049, Shaanxi (China)

    2015-12-15

    Highlights: • A transport-based kinetics code for Accelerator Driven Subcritical Reactors is developed. • The performance of different kinetics methods adapted to the ADSR is investigated. • The impacts of neutronic parameters deteriorating with fuel depletion are investigated. - Abstract: The Accelerator Driven Subcritical Reactor (ADSR) is almost external source dominated since there is no additional reactivity control mechanism in most designs. This paper focuses on beam-induced transients with an in-house developed dynamic analysis code. The performance of different kinetics methods adapted to the ADSR is investigated, including the point kinetics approximation and space–time kinetics methods. Then, the transient responds of beam trip and beam overpower are calculated and analyzed for an ADSR design dedicated for minor actinides transmutation. The impacts of some safety-related neutronics parameters deteriorating with fuel depletion are also investigated. The results show that the power distribution varying with burnup leads to large differences in temperature responds during transients, while the impacts of kinetic parameters and feedback coefficients are not very obvious. Classification: Core physic.

  11. Laser Induced Breakdown Spectroscopy Based on Single Beam Splitting and Geometric Configuration for Effective Signal Enhancement

    OpenAIRE

    Yang, Guang; Lin, Qingyu; Ding, Yu; Tian, Di; Duan, Yixiang

    2015-01-01

    A new laser induced breakdown spectroscopy (LIBS) based on single-beam-splitting (SBS) and proper optical geometric configuration has been initially explored in this work for effective signal enhancement. In order to improve the interaction efficiency of laser energy with the ablated material, a laser beam operated in pulse mode was divided into two streams to ablate/excite the target sample in different directions instead of the conventional one beam excitation in single pulse LIBS (SP-LIBS)...

  12. Development of a computerized tomographic system based on the FAN-BEAM technique

    International Nuclear Information System (INIS)

    Junqueira, M.M.; Santos, C.A.C.; Borges, J.C.

    1986-01-01

    The Nuclear Instrumentation Laboratory, at COPPE/UFRJ, concentrates its researches in the development of computerized tomographic systems, looking for applications in industrial and medical non destructive analysing techniques. In this work we have projected and constructed a tomographic prototype, based on the FAN-BEAM technique for irradiating the object under analysis. An algorithm previously developed to analyse parallel beams, was modified and adapted to the FAN-BEAM geometry. (Author) [pt

  13. SPES: A new cyclotron-based facility for research and applications with high-intensity beams

    Science.gov (United States)

    Maggiore, M.; Campo, D.; Antonini, P.; Lombardi, A.; Manzolaro, M.; Andrighetto, A.; Monetti, A.; Scarpa, D.; Esposito, J.; Silvestrin, L.

    2017-06-01

    In 2016, Laboratori Nazionali di Legnaro (Italy) started the commissioning of a new accelerator facility based on a high-power cyclotron able to deliver proton beams up to 70 MeV of energy and 700 μA current. Such a machine is the core of the Selective Production of Exotic Species (SPES) project whose main goal is to provide exotics beam for nuclear and astrophysics research and to deliver high-intensity proton beams for medical applications and neutrons generator.

  14. Active mode control of solid state laser using an intra-cavity beam shaper

    Science.gov (United States)

    Liu, Wenguang; Zhou, Qiong; Yan, Baozhu; Jiang, Zongfu

    2015-05-01

    In high power solid state lasers, thermal lens effect always give rise to the multi-modes oscillation in the resonator. The beam quality will deteriorate with the increase of output power. In this paper, an intra-cavity beam shaper is introduced to actively compensate the thermal lens in the laser resonator. One round trip ABCD matrix of the resonator with an intra-cavity beam shaper and thermal lens is calculated. The design parameters with wide stable zone are concluded through the ABCD matrix. The mode size and stability diagram of the resonator are calculated under different focal length of the thermal lens. The relationship between the adjustment of the intra-cavity beam shaper and the mode size under different thermal lenses are concluded, and general method to actively control the modes contents by adjusting the intra-cavity beam shaper is introduced. The effectiveness and performance of active mode control with the intra-cavity beam shaper are verified by simulations of the output modes of resonators. It shows that the M2 factor is well maintained below 1.6 even the focal length of the thermal lens changes from 5m to 0.5m.

  15. Recent Improvements to the Control of the CTF3 High-Current Drive Beam

    CERN Document Server

    Constance, B; Gamba, D; Skowronski, P K

    2013-01-01

    In order to demonstrate the feasibility of the CLIC multiTeV linear collider option, the drive beam complex at the CLIC Test Facility (CTF3) at CERN is providing highcurrent electron pulses for a number of related experiments. By means of a system of electron pulse compression and bunch frequency multiplication, a fully loaded, 120 MeV linac is used to generate 140 ns electron pulses of around 28 Amperes. Subsequent deceleration of this high-current drive beam demonstrates principles behind the CLIC acceleration scheme, and produces 12 GHz RF power for experimental purposes. As the facility has progressed toward routine operation, a number of studies aimed at improving the drive beam performance have been carried out. Additional feedbacks, automated steering programs, and improved control of optics and dispersion have contributed to a more stable, reproducible drive beam with consequent benefits for the experiments.

  16. Static deflection control of flexible beams by piezo-electric actuators

    Science.gov (United States)

    Baz, A. M.

    1986-01-01

    This study deals with the utilization of piezo-electric actuators in controlling the static deformation of flexible beams. An optimum design procedure is presented to enable the selection of the optimal location, thickness and excitation voltage of the piezo-electric actuators in a way that would minimize the deflection of the beam to which these actuators are bonded. Numerical examples are presented to illustrate the application of the developed optimization procedure in minimizing the structural deformation of beams of different materials when subjected to different loading and end conditions using ceramic or polymeric piezo-electric actuators. The results obtained emphasize the importance of the devised rational procedure in designing beam-actuator systems with minimal elastic distortions.

  17. Methods in Logic Based Control

    DEFF Research Database (Denmark)

    Christensen, Georg Kronborg

    1999-01-01

    Desing and theory of Logic Based Control systems.Boolean Algebra, Karnaugh Map, Quine McClusky's algorithm. Sequential control design. Logic Based Control Method, Cascade Control Method. Implementation techniques: relay, pneumatic, TTL/CMOS,PAL and PLC- and Soft_PLC implementation. PLC...

  18. Real-Time Beam Control at the LHC

    OpenAIRE

    Steinhagen, R

    2011-01-01

    At the LHC, real-time feedback systems continually control the orbit, tune, coupling, and chromaticity. Reliable and precise control of these parameters is essential for a safe and reliable machine operation. This contribution summarises the feedback performance during LHC’s first full year of operation.

  19. Current control of the electron beam formed in the magnetron gun with a secondary-emission cathode

    International Nuclear Information System (INIS)

    Dovbnya, A.N.; Reshetnyak, N.G.; Zakutin, V.V.; Chertishchev, I.A.; Romas'ko, V.P.; Dovbnyan, N.A.

    2013-01-01

    Data are reported on electron beam generation and beam current control in two types of secondary-emission cathode magnetron guns. The influence of the magnetic field value and field distribution on the formation of the beam and its parameters has been investigated in the electron energy range between 20 and 150 keV. The influence of local magnetic field variations on the cathode and the electron beam characteristics has been studied. The possibility to control the electron beam current in various ways has been demonstrated

  20. COFS 1: Beam dynamics and control technology overview

    Science.gov (United States)

    Allen, John L.

    1986-11-01

    The Control of Flexible Structures (COFS) 1 Project provides the invaluable opportunity to test, validate, and measure the effectiveness of theories, structural concepts, control systems, and flight certification processes for future missions through a research program focusing on multiple issues in large flexible structures, dynamics, and controls. The COFS 1 Project consists of a series of ground and flight activities building progressively from modeling and dynamic characterization of large space systems to the more complex issues of flexible-body control. The program objectives are to: determine the degree to which theory and ground testing can predict flight performance of next-generation low-frequency structures; evaluate structural fidelity of representative next-generation large deployable precision structure; assess math modeling requirements for large lightweight complex systems on which ground test results are questionable; determine degree to which scale model analysis and tests can be correlated to full-scale performance; evaluate system identification and state estimation algorithms on complex lightweight structures in the space environment; evaluate and verify controls/structures modeling capability; evaluate control laws and control systems; and evaluate damping effects in micro-g environment.

  1. Spatial solitons in a three-level atomic medium supported by a Laguerre-Gaussian control beam

    International Nuclear Information System (INIS)

    Hang Chao; Konotop, V. V.

    2011-01-01

    We investigate the existence and stability of various types of spatial solitons in a three-level atomic medium with Laguerre-Gaussian control beam. Radial and azimuthal modulations of the medium properties, introduced by the control beam, provide possibilities for existence of diverse soliton patterns and dynamics. Beam diffraction provides additional soliton controllability. All types of solitons can be generated at very low input energy at a few-photon level.

  2. An ion beam facility based on a 3 MV tandetron accelerator in Sichuan University, China

    Science.gov (United States)

    Han, Jifeng; An, Zhu; Zheng, Gaoqun; Bai, Fan; Li, Zhihui; Wang, Peng; Liao, Xiaodong; Liu, Mantian; Chen, Shunli; Song, Mingjiang; Zhang, Jun

    2018-03-01

    A new ion beam facility based on a 3 MV tandetron accelerator system has been installed in Sichuan University, China. The facility was developed by High Voltage Engineering Europa and consists of three high-energy beam lines including the ion beam analysis, ion implantation and nuclear physics experiment end stations, respectively. The terminal voltage stability of the accelerator is better than ±30 V, and the brightness of the proton beam is approximately 5.06 A/rad2/m2/eV. The system demonstrates a great application potential in fields such as nuclear, material and environmental studies.

  3. Development and Testing of Atomic Beam-Based Plasma Edge Diagnostics in the CIEMAT Fusion Devices

    International Nuclear Information System (INIS)

    Tafalla, D.; Tabares, F.L.; Ortiz, P.; Herrero, V.J.; Tanarro, I.

    1998-01-01

    In this report the development of plasma edge diagnostic based on atomic beam techniques fir their application in the CIEMAT fusion devices is described. The characterisation of the beams in laboratory experiments at the CSIC, together with first results in the Torsatron TJ-II are reported. Two types of beam diagnostics have been developed: a thermal (effusive) Li and a supersonic, pulsed He beams. This work has been carried out in collaboration between the institutions mentioned above under partial financial support by EURATOM. (Author) 17 refs

  4. Multi-beam synchronous measurement based on PSD phase detection using frequency-domain multiplexing

    Science.gov (United States)

    Duan, Ying; Qin, Lan; Xue, Lian; Xi, Feng; Mao, Jiubing

    2013-10-01

    According to the principle of centroid measurement, position-sensitive detectors (PSD) are commonly used for micro displacement detection. However, single-beam detection method cannot satisfy such tasks as multi-dimension position measurement, three dimension vision reconstruction, and robot precision positioning, which require synchronous measurement of multiple light beams. Consequently, we designed PSD phase detection method using frequency-domain multiplexing for synchronous detection of multiple modulated light beams. Compared to previous PSD amplitude detection method, the phase detection method using FDM has advantages of simplified measuring system, low cost, high capability of resistance to light interference as well as improved resolution. The feasibility of multi-beam synchronous measurement based on PSD phase detection using FDM was validated by multi-beam measuring experiments. The maximum non-linearity error of the multi-beam synchronous measurement is 6.62%.

  5. Application of Diamond Based Beam Loss Monitors at LHC

    CERN Document Server

    AUTHOR|(CDS)2080642; Lohmann, W; Rüdiger, S

    2013-05-14

    The Large Hadron Collider (LHC) was conceived in the 1980s and started the operation in 2008. It needed more than 20 years to plan and construct this accelerator and its experiments. Four main experiments are located around the ring, Compact Muon Solenoid (CMS), A Toroidal LHC Apparatus (ATLAS), A Large Ion Collider Experiment (ALICE) and LHC beauty (LHCb). Two beams that traveling in opposite direction in the LHC tunnel, collide in each of the experiments. The navigation of the beams is done by over 10000 magnets and each beam has a stored energy of 362MJ which correspond to the kinetic energy of a train like the TGV travelling of 150km/h. Only a small percentage of that energy can damage the material in the LHC ring or the magnets. This would mean a repair time of months or years, without taking any data. To avoid such a scenario, it is important to monitor the beam condition and measure the amount of losses of the beam. Such losses can for example happen due to dust particles in the vacuum chambers or due...

  6. Characterisation of metakaolin-based geopolymers using beam-based and conventional PALS

    Energy Technology Data Exchange (ETDEWEB)

    Guagliardo, P; Sergeant, A D; Howie, A; Wilkie, P; Williams, J; Samarin, S [Centre for Antimatter-Matter Studies, School of Physics, University of Western Australia, Crawley, WA, 6009 (Australia); Roberts, J; Weed, R; Went, M; Sullivan, J; Buckman, S [Centre for Antimatter-Matter Studies, Research School of Physical Sciences, Australian National University, Canberra, ACT, 2600 (Australia); Vance, E R, E-mail: guaglp01@student.uwa.edu.au [Institute for Materials Engineering, ANSTO, Menai, NSW, 2234 (Australia)

    2011-01-01

    The nano-porosity of metakaolin-based geopolymers and the effect of heat-treatment on porosity have been studied with conventional and beam-based positron annihilation lifetime spectroscopy (PALS). Conventional PALS found significant nano-porosity in the geopolymers, as indicated by the presence in the PALS spectrum of two long lifetime components, {tau}{sub 3} = 1.58 ns and {tau}{sub 4} = 47 ns, associated with pore diameters of approximately 0.5 and 3 nm respectively. The lifetime of the shorter component was found to decrease monotonically with successive heat treatments of 300{sup o}C and 600{sup o}C. Beam-based PALS, conducted at 5 keV, also indicated two long lifetime components, {tau}{sub 3} = 4.84 ns and {tau}{sub 4} = 54.6 ns. These are significantly longer than those observed by conventional PALS and the monotonic decrease of {tau}{sub 3} with successive heat treatments was not observed. As the beam-based PALS probed only the near-surface region, with an average implantation depth of about 350 nm, these results suggest that the near-surface structure may vary significantly from that of the bulk. This could be an inherent property of the samples or an artefact caused by surface effects or sample outgassing.

  7. Experimental control of the beam properties of laser-accelerated protons and carbon ions

    Energy Technology Data Exchange (ETDEWEB)

    Amin, Munib

    2008-12-15

    The laser generation of energetic high quality beams of protons and heavier ions has opened up the door to a plethora of applications. These beams are usually generated by the interaction of a short pulse high power laser with a thin metal foil target. They could already be applied to probe transient phenomena in plasmas and to produce warm dense matter by isochoric heating. Other applications such as the production of radioisotopes and tumour radiotherapy need further research to be put into practice. To meet the requirements of each application, the properties of the laser-accelerated particle beams have to be controlled precisely. In this thesis, experimental means to control the beam properties of laser-accelerated protons and carbon ions are investigated. The production and control of proton and carbon ion beams is studied using advanced ion source designs: Experiments concerning mass-limited (i.e. small and isolated) targets are conducted. These targets have the potential to increase both the number and the energy of laser-accelerated protons. Therefore, the influence of the size of a plane foil target on proton beam properties is measured. Furthermore, carbon ion sources are investigated. Carbon ions are of particular interest in the production of warm dense matter and in cancer radiotherapy. The possibility to focus carbon ion beams is investigated and a simple method for the production of quasi-monoenergetic carbon ion beams is presented. This thesis also provides an insight into the physical processes connected to the production and the control of laser-accelerated ions. For this purpose, laser-accelerated protons are employed to probe plasma phenomena on laser-irradiated targets. Electric fields evolving on the surface of laser-irradiated metal foils and hollow metal foil cylinders are investigated. Since these fields can be used to displace, collimate or focus proton beams, understanding their temporal and spatial evolution is crucial for the design of

  8. Experimental control of the beam properties of laser-accelerated protons and carbon ions

    International Nuclear Information System (INIS)

    Amin, Munib

    2008-12-01

    The laser generation of energetic high quality beams of protons and heavier ions has opened up the door to a plethora of applications. These beams are usually generated by the interaction of a short pulse high power laser with a thin metal foil target. They could already be applied to probe transient phenomena in plasmas and to produce warm dense matter by isochoric heating. Other applications such as the production of radioisotopes and tumour radiotherapy need further research to be put into practice. To meet the requirements of each application, the properties of the laser-accelerated particle beams have to be controlled precisely. In this thesis, experimental means to control the beam properties of laser-accelerated protons and carbon ions are investigated. The production and control of proton and carbon ion beams is studied using advanced ion source designs: Experiments concerning mass-limited (i.e. small and isolated) targets are conducted. These targets have the potential to increase both the number and the energy of laser-accelerated protons. Therefore, the influence of the size of a plane foil target on proton beam properties is measured. Furthermore, carbon ion sources are investigated. Carbon ions are of particular interest in the production of warm dense matter and in cancer radiotherapy. The possibility to focus carbon ion beams is investigated and a simple method for the production of quasi-monoenergetic carbon ion beams is presented. This thesis also provides an insight into the physical processes connected to the production and the control of laser-accelerated ions. For this purpose, laser-accelerated protons are employed to probe plasma phenomena on laser-irradiated targets. Electric fields evolving on the surface of laser-irradiated metal foils and hollow metal foil cylinders are investigated. Since these fields can be used to displace, collimate or focus proton beams, understanding their temporal and spatial evolution is crucial for the design of

  9. Instrumentation and control of the Doublet III Neutral Beam Injector System

    Energy Technology Data Exchange (ETDEWEB)

    Kohli, J.C.; Moore, C.D.; Drobnis, D.D.; Elischer, V.P.; Kilgore, R.; Uber, D.

    1980-03-01

    The hardware and software required for the operation of the Doublet III Neutral Beam Injector System (NBIS) are described. Development and implementation of this Instrumentation and Control System was divided between the major participants - General Atomic Company and Lawrence Berkeley Laboratory. The subdivision of responsibilities and the coordination of the participants' activities are described with reference to hardware and software requirements in support of the entire system. Included are a description of the operators' consoles, the interlock system and the CAMAC system. One feature of the control software is source modeling. This feature includes feedback on a shot to shot basis and adaptive control. Adaptive control permits the computer system to automatically adjust parameters after a shot, and to control the system to automatically compensate for time varying NBIS components. The Neutral Beam Power Supply features power supply modeling, fiber optic transmission of analog signals and digital control of power supply power-up/interlocks.

  10. Finite element analysis of rotating beams physics based interpolation

    CERN Document Server

    Ganguli, Ranjan

    2017-01-01

    This book addresses the solution of rotating beam free-vibration problems using the finite element method. It provides an introduction to the governing equation of a rotating beam, before outlining the solution procedures using Rayleigh-Ritz, Galerkin and finite element methods. The possibility of improving the convergence of finite element methods through a judicious selection of interpolation functions, which are closer to the problem physics, is also addressed. The book offers a valuable guide for students and researchers working on rotating beam problems – important engineering structures used in helicopter rotors, wind turbines, gas turbines, steam turbines and propellers – and their applications. It can also be used as a textbook for specialized graduate and professional courses on advanced applications of finite element analysis.

  11. The design of the electronic system on neutron beam monitor based on GEM

    International Nuclear Information System (INIS)

    Zuo Min; Zhuang Bao'an; Zhao Yubin; Chen Shaojia; Wang Na; Zhang Hongyu; Zhao Jingwei

    2012-01-01

    The Neutron Beam Monitor - a GEM based system used to monitor the neutron beams in real time - is introduced. The electronic parts are described in details, including the principles of the circuit, the system structure, the design of the Daughterboard and the logic and algorithm of the FPGA on the Monitor board. The test results are also given out in the final. (authors)

  12. SLC beam line error analysis using a model-based expert system

    International Nuclear Information System (INIS)

    Lee, M.; Kleban, S.

    1988-02-01

    Commissioning particle beam line is usually a very time-consuming and labor-intensive task for accelerator physicists. To aid in commissioning, we developed a model-based expert system that identifies error-free regions, as well as localizing beam line errors. This paper will give examples of the use of our system for the SLC commissioning. 8 refs., 5 figs

  13. Gas Transport and Density Control in the HYLIFE Heavy-Ion Beam Lines

    International Nuclear Information System (INIS)

    Debonnel, Christophe S.; Welch, Dale R.; Rose, David V.; Lawrence, Simon S.Yu; Peterson, Per F.

    2003-01-01

    The effective propagation and focusing of heavy-ion beams in the final-focus magnet region of inertial fusion target chambers require controlling the background gas density and pressure in the beam tubes. Liquid vortexes will coat the inside of the tubes next to the beam ports and will help eliminate the need for mechanical shutters to mitigate the venting of target chamber background gas into the final-focus magnet region. Before the neutralizing region, the beam space charge is high, and ablation and target debris deposition in the final-focus magnet region may cause voltage breakdown. Previous studies focused on evaluating the amount of target chamber debris reaching the entrance of the beam ports. The TSUNAMI code has now been used to assess the density, temperature, and velocity of the vortex debris transported ∼3 m up the beam tubes and reaching the final-focus magnet region, assuming that the liquid vortexes are perfectly absorbing surfaces. To further mitigate debris deposition in the final-focus magnet region, and prevent voltage breakdown, a 'magnetic shutter' has been envisaged to divert the debris out of the final-focus region. This shutter will prevent the hot ablation debris from reaching the magnet region and, coupled to some ionizing scheme, will conveniently suppress early ingression of debris into the final-focus magnet region

  14. Molecular beam detector on the MX7304 mass spectrometer base

    International Nuclear Information System (INIS)

    Akimov, V.M.; Rusin, L.Yu.; Tsyganov, F.A.

    1991-01-01

    A modified monitor for the MKh-7304 mass spectrometer installed in one of differentially evacuated chambers of the time-of-flight spectrometer. The limit vacuum under operational conditions is 10 -8 torr. The results of testing the molecular beams when recording time-of-flight spectra of Ar, Xe, N 2 are given. It is revealed that the vacuum system time conctant decrease as compared with the system with standard monitor gives an opportunity to register reliability the time-of-flight spectra of molecular beams

  15. Photovoltaic-Concentrator Based Power Beaming For Space Elevator Application

    International Nuclear Information System (INIS)

    Becker, Daniel E.; Chiang, Richard; Keys, Catherine C.; Lyjak, Andrew W.; Starch, Michael D.; Nees, John A.

    2010-01-01

    The MClimber team, at the Student Space Systems Fabrication Laboratory of the University of Michigan, has developed a prototype robotic climber for competition in the NASA sponsored Power Beaming Challenge. This paper describes the development of the system that utilizes a simple telescope to deliver an 8 kW beam to a photovoltaic panel in order to power a one kilometer climb. Its unique approach utilizes a precision GPS signal to track the panel. Fundamental systems of the project were implemented using a design strategy focusing on robustness and modularity. Development of this design and its results are presented.

  16. Dose calculation based on Cone Beam CT images

    DEFF Research Database (Denmark)

    Slot Thing, Rune

    Cone beam CT (CBCT) imaging is frequently used in modern radiotherapy to ensure the proper positioning of the patient prior to each treatment fraction. With the increasing use of CBCT imaging for image guidance, interest has grown in exploring the potential use of these 3– or 4–D medical images...... image lag, scatter within the CBCT detector assembly, x-ray beam hardening from the patient, and truncation of the CBCT field of view were implemented for clinical CBCT imaging of lung cancer patients. Through the artefact corrections, Hounsfield Units in the CBCT images were recovered and shown...

  17. Human response to individually controlled micro environment generated with localized chilled beam

    DEFF Research Database (Denmark)

    Uth, Simon C.; Nygaard, Linette; Bolashikov, Zhecho Dimitrov

    2014-01-01

    Indoor environment in a single-office room created by a localised chilled beam with individual control of the primary air flow was studied. Response of 24 human subjects when exposed to the environment generated by the chilled beam was collected via questionnaires under a 2-hour exposure including...... different work tasks at three locations in the room. Response of the subjects to the environment generated with a chilled ceiling combined with mixing air distribution was used for comparison. The air temperature in the room was kept at 26 or 28 °C. Results show no significant difference in the overall...... and local thermal sensation reported by the subjects with the two systems. Both systems were equally acceptable. At 26°C the individual control of the localised chilled beam lead to higher acceptability of the work environment. At 28°C the acceptability decreased with the two systems. It was not acceptable...

  18. A closed-loop photon beam control study for the Advanced Light Source

    International Nuclear Information System (INIS)

    Portmann, G.; Bengtsson, J.

    1993-05-01

    The third generation Advanced Light Source (ALS) will produce extremely bright photon beams using undulators and wigglers. In order to position the photon beams accurate to the micron level, a closed-loop feedback system is being developed. Using photon position monitors and dipole corrector magnets, a closed-loop system can automatically compensate for modeling uncertainties and exogenous disturbances. The following paper will present a dynamics model for the perturbations of the closed orbit of the electron beam in the ALS storage ring including the vacuum chamber magnetic field penetration effects. Using this reference model, two closed-loop feedback algorithms will be compared -- a classical PI controller and a two degree-of-freedom approach. The two degree-of-freedom method provides superior disturbance rejection while maintaining the desired performance goals. Both methods will address the need to gain schedule the controller due to the time varying dynamics introduced by changing field strengths when scanning the insertion devices

  19. Multi-image acquisition-based distance sensor using agile laser spot beam.

    Science.gov (United States)

    Riza, Nabeel A; Amin, M Junaid

    2014-09-01

    We present a novel laser-based distance measurement technique that uses multiple-image-based spatial processing to enable distance measurements. Compared with the first-generation distance sensor using spatial processing, the modified sensor is no longer hindered by the classic Rayleigh axial resolution limit for the propagating laser beam at its minimum beam waist location. The proposed high-resolution distance sensor design uses an electronically controlled variable focus lens (ECVFL) in combination with an optical imaging device, such as a charged-coupled device (CCD), to produce and capture different laser spot size images on a target with these beam spot sizes different from the minimal spot size possible at this target distance. By exploiting the unique relationship of the target located spot sizes with the varying ECVFL focal length for each target distance, the proposed distance sensor can compute the target distance with a distance measurement resolution better than the axial resolution via the Rayleigh resolution criterion. Using a 30 mW 633 nm He-Ne laser coupled with an electromagnetically actuated liquid ECVFL, along with a 20 cm focal length bias lens, and using five spot images captured per target position by a CCD-based Nikon camera, a proof-of-concept proposed distance sensor is successfully implemented in the laboratory over target ranges from 10 to 100 cm with a demonstrated sub-cm axial resolution, which is better than the axial Rayleigh resolution limit at these target distances. Applications for the proposed potentially cost-effective distance sensor are diverse and include industrial inspection and measurement and 3D object shape mapping and imaging.

  20. Computer control and monitoring of neutral beam injectors on the 2XIIB CTR experiment at LLL

    International Nuclear Information System (INIS)

    Pollock, G.G.

    1975-01-01

    The original manual control system for the 12 neutral beam injectors on the 2XIIB Machine is being integrated with a computer control system. This, in turn, is a part of a multiple computer network comprised of the three computers which are involved in the operation and instrumentation of the 2XIIB experiment. The computer control system simplifies neutral beam operation and centralizes it to a single operating position. A special purpose console utilizes computer generated graphics and interactive function entry buttons to optimize the human/machine interface. Through the facilities of the computer network, a high level control function will be implemented for the use of the experimenter in a remotely located experiment diagnositcs area. In addition to controlling the injectors in normal operation, the computer system provides automatic conditioning of the injectors, bringing rebuilt units back to full energy output with minimum loss of useful life. The computer system also provides detail archive data recording

  1. Beta Beams: an accelerator based facility to explore Neutrino oscillation physics

    CERN Document Server

    Wildner, E; Hansen, C; De Melo Mendonca, T; Stora, T; Payet, J; Chance, A; Zorin, V; Izotov, I; Rasin, S; Sidorov, A; Skalyga, V; De Angelis, G; Prete, G; Cinausero, M; Kravchuk, VL; Gramegna, F; Marchi, T; Collazuol, G; De Rosa, G; Delbar, T; Loiselet, M; Keutgen, T; Mitrofanov, S; Lamy, T; Latrasse, L; Marie-Jeanne, M; Sortais, P; Thuillier, T; Debray, F; Trophime, C; Hass, M; Hirsh, T; Berkovits, D; Stahl, A

    2011-01-01

    The discovery that the neutrino changes flavor as it travels through space has implications for the Standard Model of particle physics (SM)[1]. To know the contribution of neutrinos to the SM, needs precise measurements of the parameters governing the neutrino oscillations. This will require a high intensity beam-based neutrino oscillation facility. The EURONu Design Study will review three currently accepted methods of realizing this facility (the so-called Super-Beams, Beta Beams and Neutrino Factories) and perform a cost assessment that, coupled with the physics performance, will give means to the European research authorities to make a decision on the layout and construction of the future European neutrino oscillation facility. ”Beta Beams” produce collimated pure electron neutrino and antineutrino beams by accelerating beta active ions to high energies and letting them decay in a race-track shaped storage ring. EURONu Beta Beams are based on CERNs infrastructure and the fact that some of the already ...

  2. A Compactrio-Based Beam Loss Monitor For The SNS RF Test Cave

    International Nuclear Information System (INIS)

    Blokland, Willem; Armstrong, Gary A.

    2009-01-01

    An RF Test Cave has been built at the Spallation Neutron Source (SNS) to be able to test RF cavities without interfering the SNS accelerator operations. In addition to using thick concrete wall to minimize radiation exposure, a Beam Loss Monitor (BLM) must abort the operation within 100 usec when the integrated radiation within the cave exceeds a threshold. We choose the CompactRIO platform to implement the BLM based on its performance, cost-effectiveness, and rapid development. Each in/output module is connected through an FPGA to provide point-by-point processing. Every 10 usec the data is acquired analyzed and compared to the threshold. Data from the FPGA is transferred using DMA to the real-time controller, which communicates to a gateway PC to talk to the SNS control system. The system includes diagnostics to test the hardware and integrates the losses in real-time. In this paper we describe our design, implementation, and results

  3. Into the development of a model to assess beam shaping and polarization control effects on laser cutting

    Science.gov (United States)

    Rodrigues, Gonçalo C.; Duflou, Joost R.

    2018-02-01

    This paper offers an in-depth look into beam shaping and polarization control as two of the most promising techniques for improving industrial laser cutting of metal sheets. An assessment model is developed for the study of such effects. It is built upon several modifications to models as available in literature in order to evaluate the potential of a wide range of considered concepts. This includes different kinds of beam shaping (achieved by extra-cavity optical elements or asymmetric diode staking) and polarization control techniques (linear, cross, radial, azimuthal). A fully mathematical description and solution procedure are provided. Three case studies for direct diode lasers follow, containing both experimental data and parametric studies. In the first case study, linear polarization is analyzed for any given angle between the cutting direction and the electrical field. In the second case several polarization strategies are compared for similar cut conditions, evaluating, for example, the minimum number of spatial divisions of a segmented polarized laser beam to achieve a target performance. A novel strategy, based on a 12-division linear-to-radial polarization converter with an axis misalignment and capable of improving cutting efficiency with more than 60%, is proposed. The last case study reveals different insights in beam shaping techniques, with an example of a beam shape optimization path for a 30% improvement in cutting efficiency. The proposed techniques are not limited to this type of laser source, neither is the model dedicated to these specific case studies. Limitations of the model and opportunities are further discussed.

  4. Using a Neural Network Control Policy for Rapid Switching Between Beam Parameters in an FEL

    NARCIS (Netherlands)

    Edelen, A.L.; Biedron, S.G.; Edelen, J.P.; Milton, S.V.; van der Slot, P.J.M.

    2017-01-01

    FEL user facilities often must accommodate requests for a variety of beam parameters. This usually requires skilled operators to tune the machine, reducing the amount of available time for users. In principle, a neural network control policy that is trained on a broad range of operating states could

  5. Active control of bright electron beams with RF optics for femtosecond microscopy

    Directory of Open Access Journals (Sweden)

    J. Williams

    2017-07-01

    Full Text Available A frontier challenge in implementing femtosecond electron microscopy is to gain precise optical control of intense beams to mitigate collective space charge effects for significantly improving the throughput. Here, we explore the flexible uses of an RF cavity as a longitudinal lens in a high-intensity beam column for condensing the electron beams both temporally and spectrally, relevant to the design of ultrafast electron microscopy. Through the introduction of a novel atomic grating approach for characterization of electron bunch phase space and control optics, we elucidate the principles for predicting and controlling the phase space dynamics to reach optimal compressions at various electron densities and generating conditions. We provide strategies to identify high-brightness modes, achieving ∼100 fs and ∼1 eV resolutions with 106 electrons per bunch, and establish the scaling of performance for different bunch charges. These results benchmark the sensitivity and resolution from the fundamental beam brightness perspective and also validate the adaptive optics concept to enable delicate control of the density-dependent phase space structures to optimize the performance, including delivering ultrashort, monochromatic, high-dose, or coherent electron bunches.

  6. Coherent control of high efficiency metasurface beam deflectors with a back partial reflector

    Directory of Open Access Journals (Sweden)

    Shota Kita

    2017-04-01

    Full Text Available Recently, coherent control of absorption in metallic metasurfaces has been demonstrated, and this phenomenon was applied to intriguing light-by-light switching operation. Here we experimentally demonstrate coherent control of beam deflection by high-efficiency metasurfaces for the first time. Although the beam deflection efficiency by a metasurface is generally small, high-efficiency metasurfaces, which consist of a single layer metasurface with a back reflector, are known to exhibit significantly high deflection efficiency. A key point of our study is to replace the back reflector with a partial reflector instead, which enables light-by-light control of a high-efficiency metasurface with a pair of counter-propagating coherent beam inputs. By adjusting the partial reflector thickness appropriately, the proposed device outperforms ones without a reflector, especially for the deflection efficiency. We finally experimentally demonstrate the expected operation of the fabricated device at a visible wavelength, which reveals that the deflection efficiency of 45% (49% in theory. This result demonstrates highly efficient light-by-light control of the beam deflection by a metasurface, which opens up possible applications to ultrathin photonic devices for linear all-optical switching and logic functions.

  7. Possibility of designing television control system for welded joint formation on electron beam welding

    International Nuclear Information System (INIS)

    Lifshits, M.L.; Lobanova, N.G.

    1987-01-01

    Regression equations (models), connecting seam characteristics: width and depth with the welding bath leading front in joint gap and seam width respectively - are obtained at electron beam welding of circular articles with guaranteed clearance with application of television control system. Dispersion analysis showed the models adequancy to the process in the range, where they were identified

  8. Active control of bright electron beams with RF optics for femtosecond microscopy.

    Science.gov (United States)

    Williams, J; Zhou, F; Sun, T; Tao, Z; Chang, K; Makino, K; Berz, M; Duxbury, P M; Ruan, C-Y

    2017-07-01

    A frontier challenge in implementing femtosecond electron microscopy is to gain precise optical control of intense beams to mitigate collective space charge effects for significantly improving the throughput. Here, we explore the flexible uses of an RF cavity as a longitudinal lens in a high-intensity beam column for condensing the electron beams both temporally and spectrally, relevant to the design of ultrafast electron microscopy. Through the introduction of a novel atomic grating approach for characterization of electron bunch phase space and control optics, we elucidate the principles for predicting and controlling the phase space dynamics to reach optimal compressions at various electron densities and generating conditions. We provide strategies to identify high-brightness modes, achieving ∼100 fs and ∼1 eV resolutions with 10 6 electrons per bunch, and establish the scaling of performance for different bunch charges. These results benchmark the sensitivity and resolution from the fundamental beam brightness perspective and also validate the adaptive optics concept to enable delicate control of the density-dependent phase space structures to optimize the performance, including delivering ultrashort, monochromatic, high-dose, or coherent electron bunches.

  9. Design of active feedback controller used in the infrared beam line of SSRF

    International Nuclear Information System (INIS)

    Zhang Yongli; Tong Yajun; Zhang Zhaohong; Chen Min; Jiang Jianguo; Gong Peirong

    2014-01-01

    Background: The infrared beam line consists of many kinds of optical components that are susceptible to the external mechanical vibration, which will be further amplified by the long optical paths to seriously destroy the stability of infrared beam position. Purpose: The active feedback controller is used to stabilize the infrared beam position disturbed by the external environment. Methods: The design of the active feedback controller used in the infrared beam line of SSRF was proposed in this paper firstly, which included its background, light-path layout and operating process. Subsequently, the selections of the crucial components such as detector and actuator were discussed in details. Finally, the correction compensator design and its experimental test were also presented. The correction compensator design was realized by utilizing the frequency response method, and tested in time domain, frequency domain and mathematical model simulation of the controlled object. Results: The experimental tests included time domain step response signal of the controller, the time domain signal and its relevant magnitude spectrum in frequency domain due to the light source simulation vibration. Conclusion: The results show that the maximum effective operating band is 250 Hz and the maximum steady error is 5 μm. (authors)

  10. GENI: A graphical environment for model-based control

    International Nuclear Information System (INIS)

    Kleban, S.; Lee, M.; Zambre, Y.

    1989-10-01

    A new method to operate machine and beam simulation programs for accelerator control has been developed. Existing methods, although cumbersome, have been used in control systems for commissioning and operation of many machines. We developed GENI, a generalized graphical interface to these programs for model-based control. This ''object-oriented''-like environment is described and some typical applications are presented. 4 refs., 5 figs

  11. Influence of electron beam irradiation on growth of Phytophthora cinnamomi and its control in substrates

    International Nuclear Information System (INIS)

    MigdaŁ, Wojciech; Orlikowski, Leszek B.; Ptaszek, Magdalena; Gryczka, Urszula

    2012-01-01

    Very extensive production procedure, especially in plants growing under covering, require methods, which would allow quick elimination or substantial reduction of populations of specific pathogens without affecting the growth and development of the cultivated plants. Among soil-borne pathogens, the Phytophthora species are especially dangerous for horticultural plants. In this study, irradiation with electron beam was applied to control Phytophthora cinnamomi. The influence of irradiation dose on the reduction of in vitro growth and the population density of the pathogen in treated peat and its mixture with composted pine bark (1:1), as well as the health of Chamaecyparis lawsoniana and Lavandula angustifolia plants were evaluated. Application of irradiation at a dose of 1.5 kGy completely inhibited the in vitro development of P. cinnamomi. This irradiation effect was connected with the disintegration of the hyphae and spores of the species. Irradiation of peat and its mixture with composted pine bark with 10 kGy resulted in the inhibition of stem base rot development in Ch. lawsoniana. Symptoms of the disease were not observed when the substrates were treated with 15 kGy. In the case of L. angustifolia, stem root rot was not observed on cuttings transplanted to infected peat irradiated at a dose of 10 kGy. Irradiation of the horticultural substrates did not affect plant growth. - Highlights: ► Electron beam irradiation is effective against soil-borne pathogens. ► Application of irradiation at dose 1.5 kGy completely inhibited in vitro development of Phytophthora cinnamomi. ► Irradiation of horticultural substrata did not influence the growth of plants.

  12. Pascal software structures achieve definite control of the 24 MFTF sustaining neutral-beam power supplies

    International Nuclear Information System (INIS)

    Anon.

    1982-01-01

    Precise control of large, complex systems is not assured unless there is known to be no unintended interactions in the control system. The software controlling the sustaining neutral-beam power supplies of the Mirror Fusion Test Facility accomplishes this feat. The software structures comprise some 16,000 lines of commented Pascal code, distributed amoung 10 different tasks. Each task may control any of the 24 power supplies. All the tasks are strictly event-driven, and are not subject to any system mode. Since there is no global information in the software, we know that all the power supplies are controlled independently

  13. Ion beam-based characterization of multicomponent oxide thin films and thin film layered structures

    International Nuclear Information System (INIS)

    Krauss, A.R.; Rangaswamy, M.; Lin, Yuping; Gruen, D.M.; Schultz, J.A.; Schmidt, H.K.; Chang, R.P.H.

    1992-01-01

    Fabrication of thin film layered structures of multi-component materials such as high temperature superconductors, ferroelectric and electro-optic materials, and alloy semiconductors, and the development of hybrid materials requires understanding of film growth and interface properties. For High Temperature Superconductors, the superconducting coherence length is extremely short (5--15 Angstrom), and fabrication of reliable devices will require control of film properties at extremely sharp interfaces; it will be necessary to verify the integrity of thin layers and layered structure devices over thicknesses comparable to the atomic layer spacing. Analytical techniques which probe the first 1--2 atomic layers are therefore necessary for in-situ characterization of relevant thin film growth processes. However, most surface-analytical techniques are sensitive to a region within 10--40 Angstrom of the surface and are physically incompatible with thin film deposition and are typically restricted to ultra high vacuum conditions. A review of ion beam-based analytical methods for the characterization of thin film and multi-layered thin film structures incorporating layers of multicomponent oxides is presented. Particular attention will be paid to the use of time-of-flight techniques based on the use of 1- 15 key ion beams which show potential for use as nondestructive, real-time, in-situ surface diagnostics for the growth of multicomponent metal and metal oxide thin films

  14. Attosecond control of electron beams at dielectric and absorbing membranes

    Science.gov (United States)

    Morimoto, Yuya; Baum, Peter

    2018-03-01

    Ultrashort electron pulses are crucial for time-resolved electron diffraction and microscopy of the fundamental light-matter interaction. In this work, we study experimentally and theoretically the generation and characterization of attosecond electron pulses by optical-field-driven compression and streaking at dielectric or absorbing interaction elements. The achievable acceleration and deflection gradient depends on the laser-electron angle, the laser's electric and magnetic field directions, and the foil orientation. Electric and magnetic fields have similar contributions to the final effect and both need to be considered. Experiments and theory agree well and reveal the optimum conditions for highly efficient, velocity-matched electron-field interactions in the longitudinal or transverse direction. We find that metallic membranes are optimum for light-electron control at mid-infrared or terahertz wavelengths, but dielectric membranes are excellent in the visible and near-infrared regimes and are therefore ideal for the formation of attosecond electron pulses.

  15. Temperature control of a cyclotron magnet for stabilization of the JAERI AVF cyclotron beam

    International Nuclear Information System (INIS)

    Okumura, S.; Arakawa, K.; Fukuda, M.; Nakamura, Y.; Yokota, W.; Ishimoto, T.; Kurashima, S.; Ishibori, I.; Nara, T.; Agematsu, T.; Tamura, H.; Matsumura, A.; Sano, M.; Tachikawa, T.

    2001-01-01

    Frequent corrections of the magnetic field of the JAERI AVF cyclotron were required for keeping a beam current constant during long time operation. We observed correlation between the magnetic field and the temperature of the cyclotron magnet yoke by measuring the magnetic field with an NMR probe and the temperature with platinum resistance thermometers. As a result, this instability of a cyclotron beam was induced by temperature-change of the magnet yoke caused mainly by thermal conduction from the main coil. To restrain the thermal conduction to the yoke, we have inserted temperature-controlled copper plates between the yoke and the main coil. In addition, a temperature control system for the cooling water of the trim coils has been installed, which is independent of the total cooling system for controlling the pole tip temperature. An optimum condition of the temperature control systems for stabilizing the magnetic field has been investigated

  16. A novel beam focus control at the entrance to the ANU 14UD accelerator

    Directory of Open Access Journals (Sweden)

    De Cesare M.

    2013-12-01

    Full Text Available Tandem electrostatic accelerators often require the flexibility to operate at variety of terminal voltages to cater for various user needs. However beam transmission will only be optimal for a limited range of terminal voltages. This paper describes a focussing system that greatly expands the range of terminal voltages for optimal transmission. This is achieved by controlling the gradient of the entrance of the low-energy tube providing an additional controllable focusing element. Up to 150 kV is applied to the fifth electrode of the first unit of the accelerator tube giving control of the tube entrance lens strength. Beam tests to confirm the efficacy of the lens have been performed. These tests demonstrate that the entrance lens control eliminates the need to short out sections of the tube for low terminal voltage operation.

  17. VARIATIONALLY-BASED EFFECTIVE DYNAMIC THICKNESS FOR LAMINATED GLASS BEAMS

    Directory of Open Access Journals (Sweden)

    Jaroslav Schmidt

    2017-11-01

    Full Text Available Laminated glass, consisting of glass layers connected with transparent foils, has found its applications in civil, automotive, or marine engineering. Due to a high contrast in layer properties, mechanical response of laminated glass structures cannot be predicted using classical laminate theories. On the other hand, engineering applications demand easy-to-use formulas of acceptable accuracy. This contribution addresses such simplified models for free vibrations of laminated glass beams, with the goal to determine their natural frequencies and modal damping properties. Our strategy is to approximate the complex behavior of a laminated structure with that of an equivalent monolithic beam. Its effective thickness is determined by the variational method proposed by Galuppi and Royer-Carfagni for static problems, which we extended for modal analysis. We show that this new approach overcomes inaccuracies of the currently used dynamic effective thickness model by López-Aenlle and Pelayo.

  18. Pelletron-based MeV-range electron beam recirculation

    CERN Document Server

    Crawford, A C; Sharapa, A N; Shemyakin, A

    1999-01-01

    In this paper we describe the successful recirculation of a DC electron beam at energies 1-1.5 MeV and currents up to 0.7 A with typical relative losses of 5-20x10 sup - sup 6. Currents of 200 mA were maintained for periods of up to five hours without a single breakdown. We found that the aperture-limiting diaphragm in the gun anode significantly increased the stability of the recirculation. We also found that the stability depended strongly on vacuum pressure in the beamline. The performance of the collector with transverse magnetic fields was found to be adequate for beam currents up to 0.6 A, which is in agreement with our low-energy bench test results. (author)

  19. Beam shaping assembly optimization for (7)Li(p,n)(7)Be accelerator based BNCT.

    Science.gov (United States)

    Minsky, D M; Kreiner, A J

    2014-06-01

    Within the framework of accelerator-based BNCT, a project to develop a folded Tandem-ElectroStatic-Quadrupole accelerator is under way at the Atomic Energy Commission of Argentina. The proposed accelerator is conceived to deliver a proton beam of 30mA at about 2.5MeV. In this work we explore a Beam Shaping Assembly (BSA) design based on the (7)Li(p,n)(7)Be neutron production reaction to obtain neutron beams to treat deep seated tumors. © 2013 Elsevier Ltd. All rights reserved.

  20. Pilot Quality Control Program for Audit RT External Beams at Mexican Hospitals

    International Nuclear Information System (INIS)

    Alvarez R, J T; Tovar M, V M

    2008-01-01

    A pilot quality control program for audit 18 radiotherapy RT external beams at 13 Mexican hospitals is described--for eleven 60 Co beams and seven photon beams of 6, 10 and 15 MV from accelerators. This program contains five parts: a) Preparation of the TLD-100 powder: washing, drying and annealing (one hour 400 deg. C plus 24 hrs 80 deg. C). b) Sending two IAEA type capsules to the hospitals for irradiation at the hospital to a nominal D W = 2 Gy·c) Preparation at the SSDL of ten calibration curves CC in the range of 0.5 Gy to 6 Gy in terms of absorbed dose to water D W for 60 Co with traceability to primary laboratory NRC (Canada), according to a window irradiation: 26/10/2007-7/12/2007. d) Reading all capsules that match their hospital time irradiation and the SSDL window irradiation. f) Evaluation of the Dw imparted by the hospitals

  1. Pilot Quality Control Program for Audit RT External Beams at Mexican Hospitals

    Science.gov (United States)

    Álvarez R., J. T.; Tovar M., V. M.

    2008-08-01

    A pilot quality control program for audit 18 radiotherapy RT external beams at 13 Mexican hospitals is described—for eleven 60 Co beams and seven photon beams of 6, 10 and 15 MV from accelerators. This program contains five parts: a) Preparation of the TLD-100 powder: washing, drying and annealing (one hour 400 °C plus 24 hrs 80 °C). b) Sending two IAEA type capsules to the hospitals for irradiation at the hospital to a nominal DW = 2 Gy ṡ c ) Preparation at the SSDL of ten calibration curves CC in the range of 0.5 Gy to 6 Gy in terms of absorbed dose to water DW for 60 Co with traceability to primary laboratory NRC (Canada), according to a window irradiation: 26/10/2007-7/12/2007. d) Reading all capsules that match their hospital time irradiation and the SSDL window irradiation. f) Evaluation of the Dw imparted by the hospitals.

  2. Computational studies of impurity effects, impurity control, and neutral beam injection in large tokamaks

    Energy Technology Data Exchange (ETDEWEB)

    Post, D.E.; Goldston, R.J.; Grimm, R.C.

    1978-09-01

    Computational models have been constructed for the Princeton Large Torus (PLT), the Poloidal Divertor Experiment (PDX), and the Tokamak Fusion Test Reactor (TFTR). These models have been calibrated by comparison with current experiments and used to predict plasma parameters and delineate favorable modes of operation for future experiments. The models for PLT emphasize plasma transport and neutral beam injection heating. The models for PDX emphasize the capability of divertors for impurity and recycling control in intense neutral-beam-heated tokamaks, as well as optimization of the MHD properties of divertor-equipped tokamaks. The TFTR calculations stress the fusion aspects of a large, circular cross-section D-T tokamak with intense neutral beam injection.

  3. Height Control and Deposition Measurement for the Electron Beam Free Form Fabrication (EBF3) Process

    Science.gov (United States)

    Seufzer, William J. (Inventor); Hafley, Robert A. (Inventor)

    2017-01-01

    A method of controlling a height of an electron beam gun and wire feeder during an electron freeform fabrication process includes utilizing a camera to generate an image of the molten pool of material. The image generated by the camera is utilized to determine a measured height of the electron beam gun relative to the surface of the molten pool. The method further includes ensuring that the measured height is within the range of acceptable heights of the electron beam gun relative to the surface of the molten pool. The present invention also provides for measuring a height of a solid metal deposit formed upon cooling of a molten pool. The height of a single point can be measured, or a plurality of points can be measured to provide 2D or 3D surface height measurements.

  4. Beam profile control of line focus for x-ray laser experiment

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, G.Y.; Jitsuno, T.; Nakatsuka, M.; Daido, H.; Kato, Y.; Nakai, S. [Osaka Univ., Suita, Osaka (Japan). Inst. of Laser Engineering

    1995-12-31

    A high aspect ratio line focus on a target for the x-ray laser experiments is required for obtaining a high gain-length product. A new line focus system is developed to generate a uniform line focus. The system consists of a deformable mirror of a continuous faceplate type which provides an appropriate wavefront distribution for compensating an aberration of a line focus optics. The width and intensity distribution of 18.2mm long line focus have been improved on 2 times diffraction limit. As other application, a rectangular beam shaping from a circular defocused beam is investigated by the experiment and the diffraction calculation. The controllability of intensity distribution of laser beam by deformable mirror has been demonstrated.

  5. Signal shape registration in the JINR synchrophasotron slowly extracted beam parameter control system

    International Nuclear Information System (INIS)

    Volkov, V.I.; Kulikov, I.I.; Romanov, S.V.

    1982-01-01

    Signal shape registration in the JINR synchrophasotron slowly estracted beam parameter control system on-line with the ES-1010 computer is described. 32 input signals can be connected to the registrator. The maximum measurement rate of signal shape registration is about 38 kHz. The registrator consists of 32-channel analog multiplexer, 10-bit analog-to-digital converter, 1024-word buffer memory and control circuits. For information representation the colour TV monitor is used

  6. Global Accelerator Network, Control Systems And Beam Diagnostics

    CERN Document Server

    Raich, U

    2003-01-01

    Falling funds force all accelerator centers to look for new sources of financing and for the most efficient way of implementing new projects. This very often leads to collaborations between institutes scattered around the globe, a problem well known to big high energy physics experiments. The collaborations working on big detectors e.g. for LHC started thinking about detector acquisition and control systems which can be remotely used from their respective home institutes with minimal support on the spot. This idea was taken up by A. Wagner from DESY for the TESLA machine, who proposed the “Global Accelerator Network” (GAN) enabling users from around the world to run an accelerator remotely. Questions around this subject that immediately come to mind Is the GAN only relevant to big labs ? Or is it reasonable e.g. for operators or engineers in charge to do certain manipulations from home? Are our instruments ready for the GAN? Does the fact of being “GAN ready” increa...

  7. A Low-cost Beam Profiler Based On Cerium-doped Silica Fibers

    Science.gov (United States)

    Potkins, David Edward; Braccini, Saverio; Nesteruk, Konrad Pawel; Carzaniga, Tommaso Stefano; Vedda, Anna; Chiodini, Norberto; Timmermans, Jacob; Melanson, Stephane; Dehnel, Morgan Patrick

    A beam profiler called the Universal Beam Monitor (UniBEaM) has been developed by D-Pace Inc. (Canada) and the Albert Einstein Center for Fundamental Physics, Laboratory for High Energy Physics, University of Bern (Switzerland). The device is based on passing 100 to 600 micron cerium-doped optical fibers through a particle beam. Visible scintillation light from the sensor fibers is transmitted over distances of tens of meters to the light sensors with minimal signal loss and no susceptibility to electromagnetic fields. The probe has an insertion length of only 70 mm. The software plots the beam intensity distribution in the horizontal and vertical planes, and calculates the beam location and integrated profile area, which correlates well with total beam current. UniBEaM has a large dynamic range, operating with beam currents of ∼pA to mA, and a large range of particle kinetic energies of ∼keV to GeV, depending on the absorbed power density. Test data are presented for H- beams at 25keV for 500 μA, and H+ beams at 18MeV for 50pA to 10 μA. Maximum absorbed power density of the optical fiber before thermal damage is discussed in relation to dE/dx energy deposition as a function of particle type and kinetic energy. UniBEaM is well suited for a wide variety of beamlines including discovery science applications, radio-pharmaceutical production, hadron therapy, industrial ion beam applications including ion implantation, industrial electron beams, and ion source testing.

  8. A Plasma Based Beam Combiner for Very High Fluence and Energy

    Science.gov (United States)

    Kirkwood, Robert

    2017-10-01

    Recent work at NIF has demonstrated a plasma-based optic that combines the energy and fluence of many laser beams into a single bright beam, thus creating a new technique for designing future high energy density physics experiments. The technique uses the Cross Beam Energy Transfer (CBET) process and shows for the first time that a plasma can combine beams to produce a single beam that emerges with energy and fluence beyond that of any of those input for delivery to a range of experimental targets. In an initial demonstration multiple beams of the National Ignition Facility (NIF) laser have been combined in a plasma to produce a directed pulse of light with 4 +1 kJ of energy in its 1 ns duration which is 3.6 times the energy and 3.2 times the fluence of any of the incident beams during that period and is NIFs brightest 1ns duration beam of UV light. These enhancements are due to the non-linear interaction of the beams with a self-generated plasma diffractive optic which is far more damage resistant than existing solid state optics, and is inherently capable of producing much higher single beam fluence and radiance than solid state refractive or reflective optics can. The initial results are presently being used to further validate models of CBET which predict a larger number of non-resonant pump beams will scale up outputs still further. This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344.

  9. Multilanguage Package of slow control programs for the ATLAS Hadronic End-Cap Calorimeter Test Beam Experiment

    CERN Document Server

    Sytnik, V V

    1999-01-01

    In this article the package of slow control applications for the Liquid Argon (LAr) Hadronic End-Cap Calorimeter (HEC) test beam set-up is described. As compared to previous release, new applications have been included to fit needs of the experiment. New approaches were used to boost software reliability and to improve timing characteristics. In order to implement different part of the software the relevant programming languages were chosen: - software dealing with apparatus was implemented in Labview; - asynchronous slow control TCP server was implemented in C++; - Web monitoring of slow control system parameters was implemented in Java. The platform of slow control software is Microsoft Windows. The Java applet based monitoring of combined slow control data may also run on any platform using Netscape or Microsoft Internet Explorer.

  10. Development of an Efficient Steel Beam Section for Modular Construction Based on Six-Sigma

    Directory of Open Access Journals (Sweden)

    Tae-Hyu Ha

    2016-01-01

    Full Text Available This study presents a systematic approach for the development of an efficient steel beam section for modular construction based on Six-Sigma. Although the Six-Sigma is frequently implemented in manufacturing and other service industries, it is a relatively new concept in the area of building design and construction. As a first step in this approach, market studies and surveys are conducted to obtain the opinions of potential customers. Then the opinions of customers are converted into quality characteristics for the steel beam using the quality function deployment methodology. A steel hollow flanged channel is chosen as the main modular beam shape, and the design concept is derived and developed by applying the Pugh matrix methodology. A pilot test was performed to validate the effectiveness of the developed beam section. The results indicated that the developed channel beam section showed excellent performance and retained high accuracy in fabrication, thus resulting in a significant reduction of steel consumption.

  11. Realization of a scanning ion beam monitor; Realisation d'un dispositif de controle et d'imagerie de faisceaux balayes d'ions

    Energy Technology Data Exchange (ETDEWEB)

    Pautard, C

    2008-07-15

    During this thesis, a scanning ion beam monitor has been developed in order to measure on-line fluence spatial distributions. This monitor is composed of an ionization chamber, Hall Effect sensors and a scintillator. The ionization chamber set between the beam exit and the experiment measures the ion rate. The beam spot is localized thanks to the Hall Effect sensors set near the beam sweeping magnets. The scintillator is used with a photomultiplier tube to calibrate the ionization chamber and with an imaging device to calibrate the Hall Effect sensors. This monitor was developed to control the beam lines of a radiobiology dedicated experimentation room at GANIL. These experiments are held in the context of the research in hadron-therapy. As a matter of fact, this new cancer treatment technique is based on ion irradiations and therefore demands accurate knowledge about the relation between the dose deposit in biological samples and the induced effects. To be effective, these studies require an on-line control of the fluence. The monitor has been tested with different beams at GANIL. Fluence can be measured with a relative precision of {+-}4% for a dose rate ranging between 1 mGy/s and 2 Gy/s. Once permanently set on the beam lines dedicated to radiobiology at GANIL, this monitor will enable users to control the fluence spatial distribution for each irradiation. The scintillator and the imaging device are also used to control the position, the spot shape and the energy of different beams such as those used for hadron-therapy. (author)

  12. Device for continuous control of parameters of the beam extracted from a cyclotron

    International Nuclear Information System (INIS)

    Rezvov, V.A.; Yudin, L.I.

    1975-01-01

    A device has been developed for continuous monitoring of the parameters of an extracted cyclotron beam; the device is based on using two capacitive sensors with stroboscopic signal conversion, which are placed at the beginning of the ion duct and at its end in front of the target. The device allows a) determination of the shape of the microbunches, b) measurement of their duration and phase, and c) determination of the intensity and energy of the extracted beam. The threshold sensitivity of the device is approximately 20 nA for a signal-to-noise ratio of approximately 1. The intrinsic settling time of the signals is approximately 1 nsec

  13. Luminosity control and beam orbit stability with beta star leveling at LHC and HL-LHC

    CERN Document Server

    Gorzawski, Arkadiusz Andrzej; Wenninger, Jorg

    This thesis describes the wide subject of the luminosity leveling and its requirements for the LHC and the HL-LHC. We discuss the advantages and disadvantages of different leveling methods focusing the thesis on the beta star leveling technique. We review the beams offset build--up due to the environmental (i.e. natural ground motion) and mechanical (i.e. moving quadrupole) sources. We quantify the instrumentation requirements for the reliable and reproducible operation with small offsets at the interaction points. Last but not least, we propose a novel method for the beam offset stabilization at the collision point based on the feedback from the luminosity.

  14. An Overview of Brazilian Developments in Beamed Energy Aerospace Propulsion and Vehicle Performance Control

    International Nuclear Information System (INIS)

    Minucci, M. A. S.

    2008-01-01

    Beamed energy propulsion and beamed energy vehicle performance control concepts are equally promising and challenging. In Brazil, the two concepts are being currently investigated at the Prof Henry T Nagamatsu Laboratory of Aerothermodynamics and Hypersonics, of the Institute for Advanced Studies--IEAv, in collaboration with the Rensselaer Polytechnic Institute--RPI, Troy, NY, and the United States Air force Research Laboratory-AFRL. Until recently, only laser energy addition for hypersonic flow control was being investigated at the Laboratory using a 0.3 m nozzle exit diameter hypersonic shock tunnel, T2, and two 7 joule CO 2 TEA lasers. Flow visualization, model pressure and heat flux measurements of the laser energy addition perturbed flow around a model were produced as a result of this joint IEAv-RPI investigation. Presently, with the participation of AFRL and the newly commissioned 0.6 m. nozzle exit diameter hypersonic shock tunnel, T3, a more ambitious project is underway. Two 400 Joule Lumonics 620 CO 2 TEA lasers will deliver a 20 cm X 25 cm propulsive laser beam to a complete laser propelled air breather/rocket hypersonic engine, located inside T3 test section. Schlieren photographs of the flow inside de engine as well as surface and heat flux measurements will be performed for free stream Mach numbers ranging from 6 to 25. The present paper discusses past, present and future Brazilian activities on beamed energy propulsion and related technologies

  15. Simulation-based Investigations of Electrostatic Beam Energy Analysers

    CERN Document Server

    Pahl, Hannes

    2015-01-01

    An energy analyser is needed to measure the beam energy profile behind the REX-EBIS at ISOLDE. The device should be able to operate with an accuracy of 1 V at voltages up to 30 kV. In order to find a working concept for an electrostatic energy analyser different designs were evaluated with simulations. A spherical device and its design issues are presented. The potential deformation effects of grids at high voltages and their influence on the energy resolution were investigated. First tests were made with a grid-free ring electrode device and show promising results.

  16. Nonlinear lattice structures based on families of complex nondiffracting beams

    International Nuclear Information System (INIS)

    Rose, Patrick; Boguslawski, Martin; Denz, Cornelia

    2012-01-01

    We present a new concept for the generation of optical lattice waves. For all four families of nondiffracting beams, we are able to realize corresponding nondiffracting intensity patterns in a single setup. The potential of our approach is shown by demonstrating the optical induction of complex photonic discrete, Bessel, Mathieu and Weber lattices in a nonlinear photorefractive medium. However, our technique itself is very general and can be transferred to optical lattices in other fields such as atom optics or cold gases in order to add such complex optical potentials as a new concept to these areas as well. (paper)

  17. A surrogate-based metaheuristic global search method for beam angle selection in radiation treatment planning.

    Science.gov (United States)

    Zhang, H H; Gao, S; Chen, W; Shi, L; D'Souza, W D; Meyer, R R

    2013-03-21

    An important element of radiation treatment planning for cancer therapy is the selection of beam angles (out of all possible coplanar and non-coplanar angles in relation to the patient) in order to maximize the delivery of radiation to the tumor site and minimize radiation damage to nearby organs-at-risk. This category of combinatorial optimization problem is particularly difficult because direct evaluation of the quality of treatment corresponding to any proposed selection of beams requires the solution of a large-scale dose optimization problem involving many thousands of variables that represent doses delivered to volume elements (voxels) in the patient. However, if the quality of angle sets can be accurately estimated without expensive computation, a large number of angle sets can be considered, increasing the likelihood of identifying a very high quality set. Using a computationally efficient surrogate beam set evaluation procedure based on single-beam data extracted from plans employing equallyspaced beams (eplans), we have developed a global search metaheuristic process based on the nested partitions framework for this combinatorial optimization problem. The surrogate scoring mechanism allows us to assess thousands of beam set samples within a clinically acceptable time frame. Tests on difficult clinical cases demonstrate that the beam sets obtained via our method are of superior quality.

  18. A surrogate-based metaheuristic global search method for beam angle selection in radiation treatment planning

    International Nuclear Information System (INIS)

    Zhang, H H; D’Souza, W D; Gao, S; Shi, L; Chen, W; Meyer, R R

    2013-01-01

    An important element of radiation treatment planning for cancer therapy is the selection of beam angles (out of all possible coplanar and non-coplanar angles in relation to the patient) in order to maximize the delivery of radiation to the tumor site and minimize radiation damage to nearby organs-at-risk. This category of combinatorial optimization problem is particularly difficult because direct evaluation of the quality of treatment corresponding to any proposed selection of beams requires the solution of a large-scale dose optimization problem involving many thousands of variables that represent doses delivered to volume elements (voxels) in the patient. However, if the quality of angle sets can be accurately estimated without expensive computation, a large number of angle sets can be considered, increasing the likelihood of identifying a very high quality set. Using a computationally efficient surrogate beam set evaluation procedure based on single-beam data extracted from plans employing equally-spaced beams (eplans), we have developed a global search metaheuristic process based on the nested partitions framework for this combinatorial optimization problem. The surrogate scoring mechanism allows us to assess thousands of beam set samples within a clinically acceptable time frame. Tests on difficult clinical cases demonstrate that the beam sets obtained via our method are of superior quality. (paper)

  19. Strengthening of reinforced concrete beams with basalt-based FRP sheets: An analytical assessment

    International Nuclear Information System (INIS)

    Nerilli, Francesca; Vairo, Giuseppe

    2016-01-01

    In this paper the effectiveness of the flexural strengthening of RC beams through basalt fiber-reinforced sheets is investigated. The non-linear flexural response of RC beams strengthened with FRP composites applied at the traction side is described via an analytical formulation. Validation results and some comparative analyses confirm soundness and consistency of the proposed approach, and highlight the good mechanical performances (in terms of strength and ductility enhancement of the beam) produced by basalt-based reinforcements in comparison with traditional glass or carbon FRPs.

  20. Strengthening of reinforced concrete beams with basalt-based FRP sheets: An analytical assessment

    Energy Technology Data Exchange (ETDEWEB)

    Nerilli, Francesca [Unicusano - Università degli Studi Niccolò Cusano Telematica Roma, 00166 Rome (Italy); Vairo, Giuseppe [Università degli Studi di Roma “Tor Vergata”- (DICII), 00133 Rome (Italy)

    2016-06-08

    In this paper the effectiveness of the flexural strengthening of RC beams through basalt fiber-reinforced sheets is investigated. The non-linear flexural response of RC beams strengthened with FRP composites applied at the traction side is described via an analytical formulation. Validation results and some comparative analyses confirm soundness and consistency of the proposed approach, and highlight the good mechanical performances (in terms of strength and ductility enhancement of the beam) produced by basalt-based reinforcements in comparison with traditional glass or carbon FRPs.

  1. Modulation Transfer Function of a Gaussian Beam Based on the Generalized Modified Atmospheric Spectrum

    Directory of Open Access Journals (Sweden)

    Chao Gao

    2016-01-01

    Full Text Available This paper investigates the modulation transfer function of a Gaussian beam propagating through a horizontal path in weak-fluctuation non-Kolmogorov turbulence. Mathematical expressions are obtained based on the generalized modified atmospheric spectrum, which includes the spectral power law value of non-Kolmogorov turbulence, the finite inner and outer scales of turbulence, and other optical parameters of the Gaussian beam. The numerical results indicate that the atmospheric turbulence would produce less negative effects on the wireless optical communication system with an increase in the inner scale of turbulence. Additionally, the increased outer scale of turbulence makes a Gaussian beam influenced more seriously by the atmospheric turbulence.

  2. T-junction waveguide-based combining high power microwave beams

    International Nuclear Information System (INIS)

    Zhang Qiang; Yuan Chengwei; Liu Lie

    2011-01-01

    Waveguide-based combining microwave beams is an attractive technique for enhancing the output capacities of narrow-band high power microwave devices. A specific T-junction combiner is designed for combining the X/X band microwave beams, and the detailed combining method and experimental results are presented. In the experiments, two microwave sources which can generate gigawatt level microwaves are driven by a single accelerator simultaneously, and their operation frequencies are 9.41 and 9.60 GHz, respectively. The two microwave beams with durations of about 35 ns have been successfully combined, and no breakdown phenomenon occurs.

  3. Scanning laser beam displays based on a 2D MEMS

    Science.gov (United States)

    Niesten, Maarten; Masood, Taha; Miller, Josh; Tauscher, Jason

    2010-05-01

    The combination of laser light sources and MEMS technology enables a range of display systems such as ultra small projectors for mobile devices, head-up displays for vehicles, wearable near-eye displays and projection systems for 3D imaging. Images are created by scanning red, green and blue lasers horizontally and vertically with a single two-dimensional MEMS. Due to the excellent beam quality of laser beams, the optical designs are efficient and compact. In addition, the laser illumination enables saturated display colors that are desirable for augmented reality applications where a virtual image is used. With this technology, the smallest projector engine for high volume manufacturing to date has been developed. This projector module has a height of 7 mm and a volume of 5 cc. The resolution of this projector is WVGA. No additional projection optics is required, resulting in an infinite focus depth. Unlike with micro-display projection displays, an increase in resolution will not lead to an increase in size or a decrease in efficiency. Therefore future projectors can be developed that combine a higher resolution in an even smaller and thinner form factor with increased efficiencies that will lead to lower power consumption.

  4. Demonstration of cathode emittance dominated high bunch charge beams in a DC gun-based photoinjector

    Science.gov (United States)

    Gulliford, Colwyn; Bartnik, Adam; Bazarov, Ivan; Dunham, Bruce; Cultrera, Luca

    2015-03-01

    We present the results of transverse emittance and longitudinal current profile measurements of high bunch charge (≥100 pC) beams produced in the DC gun-based Cornell energy recovery linac photoinjector. In particular, we show that the cathode thermal and core beam emittances dominate the final 95% and core emittances measured at 9-9.5 MeV. Additionally, we demonstrate excellent agreement between optimized 3D space charge simulations and measurement, and show that the quality of the transverse laser distribution limits the optimal simulated and measured emittances. These results, previously thought achievable only with RF guns, demonstrate that DC gun based photoinjectors are capable of delivering beams with sufficient single bunch charge and beam quality suitable for many current and next generation accelerator projects such as Energy Recovery Linacs and Free Electron Lasers.

  5. Demonstration of cathode emittance dominated high bunch charge beams in a DC gun-based photoinjector

    Energy Technology Data Exchange (ETDEWEB)

    Gulliford, Colwyn, E-mail: cg248@cornell.edu; Bartnik, Adam, E-mail: acb20@cornell.edu; Bazarov, Ivan; Dunham, Bruce; Cultrera, Luca [CLASSE, Cornell University, 161 Synchrotron Drive Ithaca, New York 14853-8001 (United States)

    2015-03-02

    We present the results of transverse emittance and longitudinal current profile measurements of high bunch charge (≥100 pC) beams produced in the DC gun-based Cornell energy recovery linac photoinjector. In particular, we show that the cathode thermal and core beam emittances dominate the final 95% and core emittances measured at 9–9.5 MeV. Additionally, we demonstrate excellent agreement between optimized 3D space charge simulations and measurement, and show that the quality of the transverse laser distribution limits the optimal simulated and measured emittances. These results, previously thought achievable only with RF guns, demonstrate that DC gun based photoinjectors are capable of delivering beams with sufficient single bunch charge and beam quality suitable for many current and next generation accelerator projects such as Energy Recovery Linacs and Free Electron Lasers.

  6. Influence of electron beam irradiation on growth of Phytophthora cinnamomi and its control in substrates

    Science.gov (United States)

    MigdaŁ, Wojciech; Orlikowski, Leszek B.; Ptaszek, Magdalena; Gryczka, Urszula

    2012-08-01

    Very extensive production procedure, especially in plants growing under covering, require methods, which would allow quick elimination or substantial reduction of populations of specific pathogens without affecting the growth and development of the cultivated plants. Among soil-borne pathogens, the Phytophthora species are especially dangerous for horticultural plants. In this study, irradiation with electron beam was applied to control Phytophthora cinnamomi. The influence of irradiation dose on the reduction of in vitro growth and the population density of the pathogen in treated peat and its mixture with composted pine bark (1:1), as well as the health of Chamaecyparis lawsoniana and Lavandula angustifolia plants were evaluated. Application of irradiation at a dose of 1.5 kGy completely inhibited the in vitro development of P. cinnamomi. This irradiation effect was connected with the disintegration of the hyphae and spores of the species. Irradiation of peat and its mixture with composted pine bark with 10 kGy resulted in the inhibition of stem base rot development in Ch. lawsoniana. Symptoms of the disease were not observed when the substrates were treated with 15 kGy. In the case of L. angustifolia, stem root rot was not observed on cuttings transplanted to infected peat irradiated at a dose of 10 kGy. Irradiation of the horticultural substrates did not affect plant growth.

  7. MEMS Capacitive Micro Thermometer Based on Tip Deflection of Bimetallic Cantilever Beam

    Directory of Open Access Journals (Sweden)

    Shahriar Kouravand

    2006-08-01

    Full Text Available Thermometry is an interested field in physics and metrology. A capacitive micro thermometer based on the tip deflection of bimetallic cantilever beam was designed and described in this paper. The governing thermo mechanical equations were derived and solved analytically. The temperature rising was expressed with respect to capacitance change of a comb drive. The results of beam deflection were compared well with the existing results.

  8. Six-beam homodyne laser Doppler vibrometry based on silicon photonics technology.

    Science.gov (United States)

    Li, Yanlu; Zhu, Jinghao; Duperron, Matthieu; O'Brien, Peter; Schüler, Ralf; Aasmul, Soren; de Melis, Mirko; Kersemans, Mathias; Baets, Roel

    2018-02-05

    This paper describes an integrated six-beam homodyne laser Doppler vibrometry (LDV) system based on a silicon-on-insulator (SOI) full platform technology, with on-chip photo-diodes and phase modulators. Electronics and optics are also implemented around the integrated photonic circuit (PIC) to enable a simultaneous six-beam measurement. Measurement of a propagating guided elastic wave in an aluminum plate (speed ≈ 909 m/s @ 61.5 kHz) is demonstrated.

  9. SPS/LEP beam transfer equipment control using industrial automation components

    International Nuclear Information System (INIS)

    Aimar, A.; Berard, G.; Bretin, J.L.; Carlier, E.; Dieperink, J.H.; Laffin, M.; Mertens, V.; Verhagen, H.

    1992-01-01

    Several control systems for SPS and LEP beam transfer equipment have to be commissioned in the near future. Tools for fast software development, easy maintenance and modifications, compliance with industrial standards, and independence of specific suppliers are considered to be essential. A large fraction of the systems can be realized using off-the-shelf industrial automation components like industrial I/O systems, programmable logic controllers, or diskless PCs. Specific electronics built up in G-64 can be integrated. Diskless systems running UNIX and X Windows are foreseen as process controllers and local access media. (author)

  10. Theoretical and numerical studies on the transport of transverse beam quality in plasma-based accelerators

    International Nuclear Information System (INIS)

    Mehrling, Timon Johannes

    2014-11-01

    This work examines effects, which impact the transverse quality of electron-beams in plasma-based accelerators, by means of theoretical and numerical methods. Plasma-based acceleration is a promising candidate for future particle accelerator technologies. In plasma-based acceleration, highly intense laser beams or high-current relativistic particle beams are focused into a plasma to excite plasma-waves with extreme transverse and longitudinal electric fields. The amplitude of these fields exceed with 10-100 GV/m the ones in today's radio-frequency accelerators by several orders of magnitude, hence, in principle allowing for accordingly shorter and cheaper accelerators based on plasma. Despite the tremendous progress in the recent decade, beams from plasma accelerators are not yet achieving the quality as demanded for pivotal applications of relativistic electron-beams, e.g. free-electron lasers (FELs).Studies within this work examine how the quality can be optimized in the production of the beams and preserved during the acceleration and transport to the interaction region. Such studies cannot be approached purely analytical but necessitate numerical methods, such as the Particle-In-Cell (PIC) method, which can model kinetic, electrodynamic and relativistic plasma phenomena. However, this method is computationally too expensive for parameter-scans in three-dimensional geometries. Hence, a quasi-static PIC code was developed in connection with this work, which is significantly more effective than the full PIC method for a class of problems in plasma-based acceleration.The evolution of the emittance of beams which are injected into plasma modules was studied in this work by means of theoretical and the above numerical methods. It was shown that the beam parameters need to be matched accurately into the focusing plasma-channel in order to allow for beam-quality preservation. This suggested that new extraction and injection-techniques are required in staged plasma

  11. RF Beam control system for the Brookhaven relativistic heavy ion collider, RHIC

    International Nuclear Information System (INIS)

    Brennan, J.M.; Campbell, A.; Delong, J.; Hayes, T.; Onillon, E.; Rose, J.; Vetter, K.

    1998-01-01

    The Relativistic Heavy Ion Collider, RHIC, is two counter-rotating rings with six interaction points. The RF Beam Control system for each ring will control two 28 MHz cavities for acceleration, and five 197 MHz cavities for preserving the 5 ns bunch length during 10 hour beam stores. Digital technology is used extensively in: Direct Digital Synthesis of rf signals and Digital Signal Processing for, the realization of state-variable feedback loops, real-time calculation of rf frequency, and bunch-by-bunch phase measurement of the 120 bunches. DSP technology enables programming the parameters of the feedback loops in order to obtain closed-loop dynamics that are independent of synchrotron frequency

  12. Construction of the Faraday Cup based on fluorescent screen as an electron beam sensor

    International Nuclear Information System (INIS)

    Sutadi; Rany Saptaaji; Suhartono; Sukaryono

    2016-01-01

    The Faraday Cup based on fluorescent screen as an electron beam profile sensor at electron accelerator has been conducted. In the principle, the electron beam which obtained from the electron source and accelerated in the accelerator tube will obtain the light which can be observed visually when it interact with fluorescent material (phosphorescent). This Faraday Cup for electron beam sensor was made from the modified TV tube. The main component of this Faraday Cup construction includes: 17 inch TV tube, SS reducer flange and the vacuum adhesive. There are two kind of test has been conducted, that is the vacuum level test and the electron beam sensor test. The vacuum level test was conducted by measuring the final vacuum level that can be reach, while the electron beam sensor test was conducted by monitoring of the electron beam profile that was trapped by Faraday Cup visually. The test result shows that TV tube can be modified as the Faraday Cup to sensor electron beam in the electron accelerator. (author)

  13. Development and optimization of the LHC and the SPS beam diagnostics based on synchrotron radiation monitoring

    International Nuclear Information System (INIS)

    Trad, Georges

    2015-01-01

    Measuring the beam transverse emittance is fundamental in every accelerator, in particular for colliders, where its precise determination is essential to maximize the luminosity and thus the performance of the colliding beams. Synchrotron Radiation (SR) is a versatile tool for non-destructive beam diagnostics, since its characteristics are closely related to those of the source beam. At CERN, being the only available diagnostics at high beam intensity and energy, SR monitors are exploited as the proton beam size monitor of the two higher energy machines, the Super Proton Synchrotron (SPS) and the Large Hadron Collider (LHC). The thesis work documented in this report focused on the design, development, characterization and optimization of these beam size monitors. Such studies were based on a comprehensive set of theoretical calculations, numerical simulations and experiments. A powerful simulation tool has been developed combining conventional softwares for SR simulation and optics design, thus allowing the description of an SR monitor from its source up to the detector. The simulations were confirmed by direct observations, and a detailed performance studies of the operational SR imaging monitor in the LHC, where different techniques for experimentally validating the system were applied, such as cross-calibrations with the wire scanners at low intensity (that are considered as a reference) and direct comparison with beam sizes de-convoluted from the LHC luminosity measurements. In 2015, the beam sizes to be measured with the further increase of the LHC beam energy to 7 TeV will decrease down to ∼190 μm. In these conditions, the SR imaging technique was found at its limits of applicability since the error on the beam size determination is proportional to the ratio of the system resolution and the measured beam size. Therefore, various solutions were probed to improve the system's performance such as the choice of one light polarization, the reduction of

  14. Research into 2D Dynamics and Control of Small Oscillations of a Cross-Beam during Transportation by Two Overhead Cranes

    Directory of Open Access Journals (Sweden)

    Alexander V. Perig

    2017-01-01

    Full Text Available A new mathematical model of a 3DOF 2D mechanical system “transported cross-beam, two moving bridge cranes” has been proposed. Small system oscillations have been derived through the introduction of Lagrange equations. The numerical estimation of 3DOF system motion has been carried out with equation-based Modelica language. The present article uses the Lagrange method and numerical and optimization methods, realized with JModelica.org and Optimica freeware. The absolute swaying of the cross-beam with respect to the displacement of the two moving bridge cranes was estimated. The phase portraits of the 3DOF system for linear and angular coordinates were presented. An open loop optimal control problem was posed for the motion of the bridge cranes. A “bang-bang” control strategy was implemented for the derivation of an optimal control solution, which enables the travel of two bridge cranes at a prescribed distance for minimum time and minimum swaying of a heavy cross-beam. The derived results of the numerical simulation can be easily practically realized by crane operators with good agreement with simple engineering estimations. The proposed control strategy enables synchronous motion of two bridge cranes with a cross-beam that practically solves the posed problem of unwanted excessive oscillations of a heavy cross-beam during transportation.

  15. Impedance computations and beam-based measurements: A problem of discrepancy

    Science.gov (United States)

    Smaluk, Victor

    2018-04-01

    High intensity of particle beams is crucial for high-performance operation of modern electron-positron storage rings, both colliders and light sources. The beam intensity is limited by the interaction of the beam with self-induced electromagnetic fields (wake fields) proportional to the vacuum chamber impedance. For a new accelerator project, the total broadband impedance is computed by element-wise wake-field simulations using computer codes. For a machine in operation, the impedance can be measured experimentally using beam-based techniques. In this article, a comparative analysis of impedance computations and beam-based measurements is presented for 15 electron-positron storage rings. The measured data and the predictions based on the computed impedance budgets show a significant discrepancy. Three possible reasons for the discrepancy are discussed: interference of the wake fields excited by a beam in adjacent components of the vacuum chamber, effect of computation mesh size, and effect of insufficient bandwidth of the computed impedance.

  16. GANIL beam profile detectors

    International Nuclear Information System (INIS)

    Tribouillard, C.

    1997-01-01

    In the design phase of GANIL which started in 1977, one of the priorities of the project management was equipping the beamlines with a fast and efficient system for visualizing the beam position, thus making possible adjustment of the beam transport lines optics and facilitating beam control. The implantation of some thirty detectors was foreseen in the initial design. The assembly of installed detectors (around 190) proves the advantages of these detectors for displaying all the beams extracted from GANIL: transfer and transport lines, beam extracted from SISSI, very high intensity beam, secondary ion beams from the production target of the LISE and SPEG spectrometers, different SPIRAL project lines. All of these detectors are based on standard characteristics: - standard flange diameter (DN 160) with a standard booster for all the sensors; - identical analog electronics for all the detectors, with networking; - unique display system. The new micro-channel plate non-interceptive detectors (beam profile and ion packet lengths) make possible in-line control of the beam quality and accelerator stability. (author)

  17. Experiments on laser beam jitter control with applications to a shipboard free electron laser

    OpenAIRE

    Bateman, Brett E.

    2007-01-01

    A Free Electron Laser (FEL) shows potential as an effective defensive weapon for a naval ship against today's modern weapons such as supersonic anti-ship missiles. A laser can destroy these fast and highly maneuverable missiles at the speed of light. Several obstacles must be overcome to employ this weapon on a naval ship. This thesis discusses several methods for passive and active jitter control of a guided optical beam which might be employed in a FEL weapon system. Vibration experime...

  18. Nonlinear control via approximate input-output linearization - The ball and beam example

    Science.gov (United States)

    Hauser, John; Sastry, Shankar; Kokotovic, Petar

    1992-01-01

    A study is made of approximate input-output linearization of nonlinear systems which fail to have a well defined relative degree. For such systems, a method is provided for constructing approximate systems that are input-output linearizable. The analysis presented in this note is motivated through its application to a common undergraduate control laboratory experiment, the ball and beam system, where it is shown to be more effective for trajectory tracking than the standard Jacobian linearization.

  19. The Case for Muon-based Neutrino Beams

    Energy Technology Data Exchange (ETDEWEB)

    Huber, Patrick [Virginia Polytechnic Inst. and State Univ. (Virginia Tech), Blacksburg, VA (United States); Bross, Alan [Fermi National Accelerator Laboratory (FNAL), Batavia, IL (United States); Palmer, Mark [Fermi National Accelerator Laboratory (FNAL), Batavia, IL (United States)

    2014-11-03

    For the foreseeable future, high energy physics accelerator capabilities in the US will be deployed to study the physics of the neutrino sector. In this context, it is useful to explore the sensitivities and limiting systematic effects of the planned neutrino oscillation program, so that we can evaluate the issues that must be addressed in order to ensure the success of these efforts. It is only in this way that we will ultimately be able to elucidate the fundamental physics processes involved. We conclude that success can only be guaranteed by, at some point in the future, being able to deploy muon accelerator capabilities. Such capabilities provide the only route to precision neutrino beams with which to study and mitigate, at the sub-percent level, the limiting systematic issues of future oscillation measurements. Thus this analysis argues strongly for maintaining a viable accelerator research program towards future muon accelerator capabilities.

  20. FIRST BEAM TESTS OF THE APS MBA UPGRADE ORBIT FEEDBACK CONTROLLER

    Energy Technology Data Exchange (ETDEWEB)

    Sereno, N. S.; Arnold, N.; Brill, A.; Bui, H.; Carwardine, J.; Decker, G.; Deriy, B.; Emery, L.; Farnsworth, R.; Fors, T.; Keane, R.; Lenkszus, F.; Lill, R.; Paskvan, D.; Pietryla, A.; Shang, H.; Shoaf, S.; Veseli, S.; Wang, J.; Xu, S.; Yang, B.X.

    2017-03-25

    The new orbit feedback system required for the APS multi-bend acromat (MBA) ring must meet challenging beam stability requirements. The AC stability requirement is to correct rms beam motion to 10 % the rms beam size at the insertion device source points from 0.01 to 1000 Hz. The vertical plane represents the biggest challenge for AC stability which is required to be 400 nm rms for a 4 micron vertical beam size. In addition long term drift over a period of 7 days is required to be 1 micron or less at insertion de- vice BPMs and 2 microns for arc bpms. We present test re- sults of theMBA prototype orbit feedback controller (FBC) in the APS storage ring. In this test, four insertion device BPMs were configured to send data to the FBC for process- ing into four fast corrector setpoints. The configuration of four bpms and four fast correctors creates a 4-bump and the configuration of fast correctors is similar to what will be implemented in the MBA ring. We report on performance benefits of increasing the sampling rate by a factor of 15 to 22.6 kHz over the existing APS orbit feedback system, lim- itations due to existing storage ring hardware and extrapo- lation to theMBA orbit feedback design. FBC architecture, signal flow and processing design will also be discussed.

  1. Controlling the optical fiber output beam profile by focused ion beam machining of a phase hologram on fiber tip.

    Science.gov (United States)

    Han, Jiho; Sparkes, Martin; O'Neill, William

    2015-02-01

    A phase hologram was machined on an optical fiber tip using a focused ion beam (FIB) system so that a ring-shaped beam emerges from the fiber tip. The fiber used for this work was a commercial single-mode optical fiber patch cable for a design wavelength of 633 nm with a germanosilicate core. The ring-shaped beam was chosen to ensure a simple geometry in the required phase hologram, though the Gerchberg-Saxton algorithm can be used to calculate a hologram for an arbitrary beam shape. The FIB machining took approximately 45 min at 30 kV and 200 pA. The radius of the resulting ring beam was 0.083 m at 1 m standoff, as compared to 0.1 m as was initially desired. Results suggest that this imaging technique may provide a basis for a beam-shaping method with several advantages over the current commercial solutions, having permanent alignment, compactness, and mechanical robustness. However, it would appear that minimizing the speckle pattern will remain a critical challenge for this technique to become widely implemented.

  2. CONTROL SYSTEM FOR THE LITHIUM BEAM EDGE PLASMA CURRENT DENSITY DIAGNOSTIC ON THE DIII-D TOKAMAK

    International Nuclear Information System (INIS)

    PEAVY, J.J.; CARY, W.P; THOMAS, D.M; KELLMAN, D.H.; HOYT, D.M; DELAWARE, S.W.; PRONKO, S.G.E.; HARRIS, T.E.

    2004-03-01

    OAK-B135 An edge plasma current density diagnostic employing a neutralized lithium ion beam system has been installed on the DIII-D tokamak. The lithium beam control system is designed around a GE Fanuc 90-30 series PLC and Cimplicity(reg s ign) HMI (Human Machine Interface) software. The control system operates and supervises a collection of commercial and in-house designed high voltage power supplies for beam acceleration and focusing, filament and bias power supplies for ion creation, neutralization, vacuum, triggering, and safety interlocks. This paper provides an overview of the control system, while highlighting innovative aspects including its remote operation, pulsed source heating and pulsed neutralizer heating, optimizing beam regulation, and beam ramping, ending with a discussion of its performance

  3. Compensation of Hologram Distortion by Controlling Defocus Component in Reference Beam Wavefront for Angle Multiplexed Holograms

    Science.gov (United States)

    Muroi, T.; Kinoshita, N.; Ishii, N.; Kamijo, K.; Kawata, Y.; Kikuchi, H.

    2013-12-01

    Holographic memory has the potential to function as a recording system with a large capacity and high data-transfer-rate. Photopolymer materials are typically used as a write-once recording medium. When holograms are recorded on this medium, they can distort due to shrinkage or expansion of the materials, which degrades the reconstructed image and causes a higher bit error rate (bER) of the reproduced data. We propose optically compensating for hologram distortion by controlling aberration components in the reference beam wavefront while reproducing data, thereby improving the reproduced data quality. First, we investigated the relation between each aberration component of the reference beam and the signal to noise ratio (SNR) of the reproduced data using numerical simulation and found that horizontal tilt and the defocus component affect the SNR. Next, we experimentally evaluated the reproduced data by controlling the defocus component in the reference beam and found that the bER of the reproduced data could be decreased by controlling the defocus center with respect to the hologram position and phase modulation depth of the defocus component. Then, we investigated a practical control method of the defocus component using an evaluation value similar to the definition of the SNR for actual data reproduction from holograms. Using a defocus controlled wavefront enabled us to decrease the bER from 3.54 x 10^-3 with a plane wave to 3.14 x 10^-4. We also investigated how to reduce the bERs of reproduced data in angle multiplexed holograms. By using a defocus controlled wavefront to compensate for hologram distortion on the 40th data page in 80-page angle multiplexed holograms, the bERs of all pages could be decreased to less than 1x10^-3. We showed that controlling the defocus component is an effective way to compensate for hologram distortion and to decrease the bER of reproduced data in holographic memory.

  4. Verification of a pencil beam based treatment planning system: output factors for open photon beams shaped with MLC or blocks

    International Nuclear Information System (INIS)

    Hansson, H.

    1999-01-01

    The accuracy of monitor unit calculations from a pencil beam based, three-dimensional treatment planning system (3D TPS) has been evaluated for open irregularly shaped photon fields. The dose per monitor unit was measured in water and in air for x-ray beam qualities from 6 to 15 MV. The fields were shaped either with a multileaf collimator (MLC) or with customized alloy blocks. Calculations from the 3D TPS were compared with measurements. The agreement between calculated and measured dose per monitor unit depended on field size and the amount of blocking and was within 3% for the MLC-shaped fields. The deviation could be traced to limitations in head scatter modelling for the MLC. For fields shaped with alloy blocks, the dose per monitor unit was calculated to be within 1.6% of measured values for all fields studied. The measured and calculated relative phantom scatter for fields with the same equivalent field size were identical for MLC and alloy shaped fields. These results indicate that the accuracy in the TPS calculations for open irregular fields, shaped with MLC or blocks, is satisfactory for clinical situations. (author)

  5. Applications of power beaming from space-based nuclear power stations

    International Nuclear Information System (INIS)

    Powell, J.R.; Botts, T.E.; Hertzberg, A.

    1981-01-01

    Power beaming from space-based reactor systems is examined using an advanced compact, lightweight Rotating Bed Reactor (RBR). Closed Brayton power conversion efficiencies in the range of 30 to 40% can be achieved with turbines, with reactor exit temperatures on the order of 2000 0 K and a liquid drop radiator to reject heat at temperatures of approx. 500 0 K. Higher RBR coolant temperatures (up to approx. 3000 0 K) are possible, but gains in power conversion efficiency are minimal, due to lower expander efficiency (e.g., a MHD generator). Two power beaming applications are examined - laser beaming to airplanes and microwave beaming to fixed ground receivers. Use of the RBR greatly reduces system weight and cost, as compared to solar power sources. Payback times are a few years at present prices for power and airplane fuel

  6. Correction of Magnetic Optics and Beam Trajectory Using LOCO Based Algorithm with Expanded Experimental Data Sets

    Energy Technology Data Exchange (ETDEWEB)

    Romanov, A.; Edstrom, D.; Emanov, F. A.; Koop, I. A.; Perevedentsev, E. A.; Rogovsky, Yu. A.; Shwartz, D. B.; Valishev, A.

    2017-03-28

    Precise beam based measurement and correction of magnetic optics is essential for the successful operation of accelerators. The LOCO algorithm is a proven and reliable tool, which in some situations can be improved by using a broader class of experimental data. The standard data sets for LOCO include the closed orbit responses to dipole corrector variation, dispersion, and betatron tunes. This paper discusses the benefits from augmenting the data with four additional classes of experimental data: the beam shape measured with beam profile monitors; responses of closed orbit bumps to focusing field variations; betatron tune responses to focusing field variations; BPM-to-BPM betatron phase advances and beta functions in BPMs from turn-by-turn coordinates of kicked beam. All of the described features were implemented in the Sixdsimulation software that was used to correct the optics of the VEPP-2000 collider, the VEPP-5 injector booster ring, and the FAST linac.

  7. A Monte Carlo-based treatment-planning tool for ion beam therapy

    CERN Document Server

    Böhlen, T T; Dosanjh, M; Ferrari, A; Haberer, T; Parodi, K; Patera, V; Mairan, A

    2013-01-01

    Ion beam therapy, as an emerging radiation therapy modality, requires continuous efforts to develop and improve tools for patient treatment planning (TP) and research applications. Dose and fluence computation algorithms using the Monte Carlo (MC) technique have served for decades as reference tools for accurate dose computations for radiotherapy. In this work, a novel MC-based treatment-planning (MCTP) tool for ion beam therapy using the pencil beam scanning technique is presented. It allows single-field and simultaneous multiple-fields optimization for realistic patient treatment conditions and for dosimetric quality assurance for irradiation conditions at state-of-the-art ion beam therapy facilities. It employs iterative procedures that allow for the optimization of absorbed dose and relative biological effectiveness (RBE)-weighted dose using radiobiological input tables generated by external RBE models. Using a re-implementation of the local effect model (LEM), theMCTP tool is able to perform TP studies u...

  8. Design concept for a CAMAC based beam tuner for the pelletron accelerator

    International Nuclear Information System (INIS)

    Gore, J.A.; Kulkarni, S.; Tambwekar, V.V.; Bhagwat, P.V.

    2003-01-01

    The 14 UD Pelletron accelerator has been in operation since 1989. It is a tandem accelerator, where negative ions are injected at maximum -300 kV and after the stripper in the terminal, positive ions achieve a maximum energy of 14(q+ I) MeV. The beam is transported from the ion source up to the target area with the help of various beam optic devices like quadrupoles and steerers. In this process the magnetic field of the focusing and steering magnets is adjusted with the help of voltage or current power supplies. At present the beam tuning process is operator driven. This paper describes a design concept of a CAMAC based beam tuner card that is implemented using an FPGA and which is under development at the Pelletron accelerator facility

  9. Development of a negative ion-based neutral beam injector in Novosibirsk.

    Science.gov (United States)

    Ivanov, A A; Abdrashitov, G F; Anashin, V V; Belchenko, Yu I; Burdakov, A V; Davydenko, V I; Deichuli, P P; Dimov, G I; Dranichnikov, A N; Kapitonov, V A; Kolmogorov, V V; Kondakov, A A; Sanin, A L; Shikhovtsev, I V; Stupishin, N V; Sorokin, A V; Popov, S S; Tiunov, M A; Belov, V P; Gorbovsky, A I; Kobets, V V; Binderbauer, M; Putvinski, S; Smirnov, A; Sevier, L

    2014-02-01

    A 1000 keV, 5 MW, 1000 s neutral beam injector based on negative ions is being developed in the Budker Institute of Nuclear Physics, Novosibirsk in collaboration with Tri Alpha Energy, Inc. The innovative design of the injector features the spatially separated ion source and an electrostatic accelerator. Plasma or photon neutralizer and energy recuperation of the remaining ion species is employed in the injector to provide an overall energy efficiency of the system as high as 80%. A test stand for the beam acceleration is now under construction. A prototype of the negative ion beam source has been fabricated and installed at the test stand. The prototype ion source is designed to produce 120 keV, 1.5 A beam.

  10. Differential Quadrature Method Based Study of Vibrational Behaviour of Inclined Edge Cracked Beams

    Directory of Open Access Journals (Sweden)

    Srivastava Shivani

    2017-01-01

    Full Text Available The study of vibration behaviour of cracked system is an important area of research. In the present work we present a mathematical model to study the effect of inclination, location and size of the crack on the vibrational behavior of beam with different boundary conditions. The model is based on the assumption that the equivalent flexible rigidity of the cracked beam can be written in terms of the flexible rigidity of the uncracked beam, based on the energy approach as proposed by earlier researchers. In the present work the Differential Quadrature Method (DQM is used to solve equation of motion derived by using Euler’s beam theory. The primary interest of the paper is to study the effect of inclined crack on natural frequency. We have also studied the beam vibration with and without vertical edge crack as a special case to validate the model. The DQM results for the natural frequencies of cracked beams agree well with other literature values and ANSYS solutions.

  11. Beam shaping to improve holography techniques based on spatial light modulators

    Science.gov (United States)

    Laskin, Alexander; Laskin, Vadim

    2013-03-01

    Modern holographic techniques based on Spatial Light Modulators get serious benefits from providing uniform intensity distribution of a laser beam: more predictable and reliable operation, higher efficiency of laser energy usage, more simple mathematical description of diffraction transformations, etc. Conversion of Gaussian intensity distribution of TEM00 lasers to flattop one is successfully realized with refractive field mapping beam shapers like piShaper, which operational principle presumes transformation with high flatness of output wavefront, conserving of beam consistency, providing collimated output beam of low divergence, high transmittance, extended depth of field, negligible residual wave aberration, and achromatic design provides capability to work with several laser sources with different wavelengths simultaneously. Applying of these beam shapers brings serious benefits to the Spatial Light Modulator based techniques like Computer Generated Holography, Dot-Matrix mastering of security holograms, holographic data storage. This paper will describe some design basics of refractive beam shapers of the field mapping type and optical layouts of their applying in holographic systems. Examples of real implementations and experimental results will be presented as well.

  12. Nonlinear behavior of capacitive micro-beams based on strain gradient theory

    International Nuclear Information System (INIS)

    Fathalilou, Mohammad; Sadeghi, Morteza; Rezazadeh, Ghader

    2014-01-01

    This paper studies the size dependent behavior of materials in MEMS structures. This behavior becomes noticeable for a structure when the characteristic size such as thickness or diameter is close to its internal length-scale parameter and is insignificant for the high ratio of the characteristic size to the length-scale parameter, which is the case of the silicon base micro-beams. However, in some types of micro-beams like gold or nickel bases, the size dependent effect cannot be overlooked. In such cases, ignoring this behavior in modeling will lead to incorrect results. Some previous researchers have applied classic beam theory on their models and imposed a considerable hypothetical value of residual stress to match their theoretical results with the experimental ones. The equilibrium positions or fixed points of the gold and nickel micro-beams are obtained and shown that for a given DC voltage, there is a considerable difference between the obtained fixed points using classic beam theory, modified couple stress theory, and modified strain gradient theory. In addition, it is shown that the calculated static and dynamic pull-in voltages using higher order theories are much closer to the experimental results and are higher several times than those obtained by classic beam theory.

  13. SU-E-T-610: Phosphor-Based Fiber Optic Probes for Proton Beam Characterization

    Energy Technology Data Exchange (ETDEWEB)

    Darafsheh, A; Soldner, A; Liu, H; Kassaee, A; Zhu, T; Finlay, J [Univ Pennsylvania, Philadelphia, PA (United States)

    2015-06-15

    Purpose: To investigate feasibility of using fiber optics probes with rare-earth-based phosphor tips for proton beam radiation dosimetry. We designed and fabricated a fiber probe with submillimeter resolution (<0.5 mm3) based on TbF3 phosphors and evaluated its performance for measurement of proton beam including profiles and range. Methods: The fiber optic probe with TbF3 phosphor tip, embedded in tissue-mimicking phantoms was irradiated with double scattering proton beam with energy of 180 MeV. Luminescence spectroscopy was performed by a CCD-coupled spectrograph to analyze the emission spectra of the fiber tip. In order to measure the spatial beam profile and percentage depth dose, we used singular value decomposition method to spectrally separate the phosphors ionoluminescence signal from the background Cerenkov radiation signal. Results: The spectra of the TbF3 fiber probe showed characteristic ionoluminescence emission peaks at 489, 542, 586, and 620 nm. By using singular value decomposition we found the contribution of the ionoluminescence signal to measure the percentage depth dose in phantoms and compared that with measurements performed with ion chamber. We observed quenching effect at the spread out Bragg peak region, manifested as under-responding of the signal, due to the high LET of the beam. However, the beam profiles were not dramatically affected by the quenching effect. Conclusion: We have evaluated the performance of a fiber optic probe with submillimeter resolution for proton beam dosimetry. We demonstrated feasibility of spectral separation of the Cerenkov radiation from the collected signal. Such fiber probes can be used for measurements of proton beams profile and range. The experimental apparatus and spectroscopy method developed in this work provide a robust platform for characterization of proton-irradiated nanophosphor particles for ultralow fluence photodynamic therapy or molecular imaging applications.

  14. Closed-Loop Process Control for Electron Beam Freeform Fabrication and Deposition Processes

    Science.gov (United States)

    Taminger, Karen M. (Inventor); Hafley, Robert A. (Inventor); Martin, Richard E. (Inventor); Hofmeister, William H. (Inventor)

    2013-01-01

    A closed-loop control method for an electron beam freeform fabrication (EBF(sup 3)) process includes detecting a feature of interest during the process using a sensor(s), continuously evaluating the feature of interest to determine, in real time, a change occurring therein, and automatically modifying control parameters to control the EBF(sup 3) process. An apparatus provides closed-loop control method of the process, and includes an electron gun for generating an electron beam, a wire feeder for feeding a wire toward a substrate, wherein the wire is melted and progressively deposited in layers onto the substrate, a sensor(s), and a host machine. The sensor(s) measure the feature of interest during the process, and the host machine continuously evaluates the feature of interest to determine, in real time, a change occurring therein. The host machine automatically modifies control parameters to the EBF(sup 3) apparatus to control the EBF(sup 3) process in a closed-loop manner.

  15. Interlaminar Stresses by Refined Beam Theories and the Sinc Method Based on Interpolation of Highest Derivative

    Science.gov (United States)

    Slemp, Wesley C. H.; Kapania, Rakesh K.; Tessler, Alexander

    2010-01-01

    Computation of interlaminar stresses from the higher-order shear and normal deformable beam theory and the refined zigzag theory was performed using the Sinc method based on Interpolation of Highest Derivative. The Sinc method based on Interpolation of Highest Derivative was proposed as an efficient method for determining through-the-thickness variations of interlaminar stresses from one- and two-dimensional analysis by integration of the equilibrium equations of three-dimensional elasticity. However, the use of traditional equivalent single layer theories often results in inaccuracies near the boundaries and when the lamina have extremely large differences in material properties. Interlaminar stresses in symmetric cross-ply laminated beams were obtained by solving the higher-order shear and normal deformable beam theory and the refined zigzag theory with the Sinc method based on Interpolation of Highest Derivative. Interlaminar stresses and bending stresses from the present approach were compared with a detailed finite element solution obtained by ABAQUS/Standard. The results illustrate the ease with which the Sinc method based on Interpolation of Highest Derivative can be used to obtain the through-the-thickness distributions of interlaminar stresses from the beam theories. Moreover, the results indicate that the refined zigzag theory is a substantial improvement over the Timoshenko beam theory due to the piecewise continuous displacement field which more accurately represents interlaminar discontinuities in the strain field. The higher-order shear and normal deformable beam theory more accurately captures the interlaminar stresses at the ends of the beam because it allows transverse normal strain. However, the continuous nature of the displacement field requires a large number of monomial terms before the interlaminar stresses are computed as accurately as the refined zigzag theory.

  16. A novel process control method for a TT-300 E-Beam/X-Ray system

    Science.gov (United States)

    Mittendorfer, Josef; Gallnböck-Wagner, Bernhard

    2018-02-01

    This paper presents some aspects of the process control method for a TT-300 E-Beam/X-Ray system at Mediscan, Austria. The novelty of the approach is the seamless integration of routine monitoring dosimetry with process data. This allows to calculate a parametric dose for each production unit and consequently a fine grain and holistic process performance monitoring. Process performance is documented in process control charts for the analysis of individual runs as well as historic trending of runs of specific process categories over a specified time range.

  17. Optimal Placement of Piezoelectric Plates to Control Multimode Vibrations of a Beam

    Directory of Open Access Journals (Sweden)

    Fabio Botta

    2013-01-01

    Full Text Available Damping of vibrations is often required to improve both the performance and the integrity of engineering structures, for example, gas turbine blades. In this paper, we explore the possibility of using piezoelectric plates to control the multimode vibrations of a cantilever beam. To develop an effective control strategy and optimize the placement of the active piezoelectric elements in terms of vibrations amplitude reduction, a procedure has been developed and a new analytical solution has been proposed. The results obtained have been corroborated by comparison with the results from a multiphysics finite elements package (COMSOL, results available in the literature, and experimental investigations carried out by the authors.

  18. Operational amplifier based stretcher for stripline beam position monitors

    International Nuclear Information System (INIS)

    Sellyey, W.C.; Kruse, R.W.

    1991-01-01

    The stretcher amp was designed to accommodate existing instrumentation at the Boeing Free-Electron Laser (FEL) facility. The beam format for this system consists of two macropulses per second. Each macropulse contains several hundred micropulses separated by 462ns. Thus, 462ns is the upper limit to which the pulse can be stretched. The corresponding filter bandwidth would be about 3 Mhz. In the stripline data acquisition system, one of six striplines is switched to a single transient digitizer channel. Tektronix TSS46 microwave relay switches are used. The output of the TSS46 goes into stretcher amps described here. The resulting signals are digitized by Analytek 2004S or 2008S transient digitizers. The transient digitizer timing is such that it samples the negative peak of the stripline signal from each micropulse. Its analogue bandwidth is 300 Mhz. For good temperature stability and linearity, the stretcher bandwidth should be much less than 300MHz, for example 30Mhz. This defines a lower limit to the pulse width. 30Mhz was chosen for the filter bandwidth. Making the bandwidth smaller would have required more gain in the output amplifier. This would have resulted in too much noise at the output. Additionally, temperature drift and nonlinearity would also increase

  19. Dual circularly polarized broadside beam antenna based on metasurfaces

    Science.gov (United States)

    Tellechea, A.; Caminita, F.; Martini, E.; Ederra, I.; Teniente, J.; Iriarte, J. C.; Gonzalo, R.; Maci, S.

    2018-02-01

    Design details of a Ku band metasurface (MTS) antenna with dual circularly polarized (CP) broadside radiation is shown in this work. By means of the surface impedance tensor modulation, synchronized propagation of two transversal magnetic (TM) and transverse electric (TE) surface waves (SWs) is ensured in the structure, which contribute to the radiation in broadside direction by the generation of a CP leaky wave. The structure is implemented by elliptical subwavelength metallic elements with a cross-shaped aperture in the center, printed on top of a thin substrate with high permittivity (AD1000 with a thickness of λ0/17). For the experimental validation, the MTS prototype has been excited employing an orthomode transducer composed by a metallic stepped septum inside an air-filled waveguide. Two orthogonal TE11 modes excited with ±90° phase shift in the feed couple with the TM and TE SWs supported by the MTS and generate RHCP or LHCP broadside beam. Experimental results are compared with the simulation predictions. Finally, conclusions are drawn.

  20. Quality control and radioprotection in dental cone beam computed tomography - case study

    International Nuclear Information System (INIS)

    Rodrigues, Ligiane C.N.; Ferreira, Nadya M.P.D.

    2011-01-01

    The radiological protection in medical and odontologic radiology follows The Order (Portaria) 453/98 of the Ministry of Health, which presents the minimum set of tests for the constancy X-ray equipment. These tests follow the procedures set forth in the Resolution no. 64, the National Agency for Sanitary Vigilance. This work aims to show a study on dental cone beam computed tomography (CBCT), evaluating the physical parameters that influence the performance and image quality and presenting the appropriate tests to this new system. The authors analyzed the tests specific for computed tomography (CT) of the Resolution no. 64, feasibility assessment of them and if their interpretations are compatible with CBCT. Once determined if testing is feasible, compare with those presented in the manual provided by the equipment manufacturer. The CT scanner used was the Mini-Cat Tomography Scanner Xoran Technologies of KAVO. In the study it was verified that four tests could be reproduced in CBCT: noise, accuracy and uniformity in the number of CT of water and spatial resolution. Considering experimental data, the methodology and tolerance of manufacturer for the first two tests were more appropriate. For the uniformity test of the CT number, we recommend using the phantom quality control. Three new tests were suggested to be made in the quality control of the Cone Beam: linearity, artifacts and alignment of the beam. (author)

  1. Optical Beam Deflection Based AFM with Integrated Hardware and Software Platform for an Undergraduate Engineering Laboratory

    Directory of Open Access Journals (Sweden)

    Siu Hong Loh

    2017-02-01

    Full Text Available Atomic force microscopy (AFM has been used extensively in nanoscience research since its invention. Recently, many teaching laboratories in colleges, undergraduate institutions, and even high schools incorporate AFM as an effective teaching tool for nanoscience education. This paper presents an optical beam deflection (OBD based atomic force microscope, designed specifically for the undergraduate engineering laboratory as a teaching instrument. An electronic module for signal conditioning was built with components that are commonly available in an undergraduate electronic laboratory. In addition to off-the-shelf mechanical parts and optics, the design of custom-built mechanical parts waskept as simple as possible. Hence, the overall cost for the setup is greatly reduced. The AFM controller was developed using National Instruments Educational Laboratory Virtual Instrumentation Suite (NI ELVIS, an integrated hardware and software platform which can be programmed in LabVIEW. A simple yet effective control algorithm for scanning and feedback control was developed. Despite the use of an educational platform and low-cost components from the undergraduate laboratory, the developed AFM is capable of performing imaging in constant-force mode with submicron resolution and at reasonable scanning speed (approximately 18 min per image. Therefore, the AFM is suitable to be used as an educational tool for nanoscience. Moreover, the construction of the system can be a valuable educational experience for electronic and mechanical engineering students.

  2. Modeling feedback control of unstable separatrix location in beam-driven field-reversed configurations

    Science.gov (United States)

    Rath, N.; Onofri, M.; Dettrick, S. A.; Barnes, D. C.; Romero, J.

    2017-04-01

    We present a linear, one-parameter model for rigid displacement of a toroidally symmetric plasma. When the feedback control is feasible, plasma inertia can be neglected, and the instability growth rate is proportional to wall resistivity. We benchmark the linear model against non-linear, hybrid simulations of an axially unstable, beam-driven field-reversed configuration to fix the free parameter of the model. The resulting parameter-free model is validated using linear and non-linear closed-loop simulations with active feedback control by voltage-controlled coils. In closed loop simulations, the predictions of the parameter-free linear model agree satisfactory with the non-linear results. Implications for the feedback control of the positional instability in experiments are discussed. The presented model has been used to guide the design of the feedback control hardware in the C-2W experiment.

  3. Monitoring and control system for the beam-transport field in an induction linac

    International Nuclear Information System (INIS)

    Wang Huacen; Lai Qinggui; Zou Yong

    1998-12-01

    The monitoring and control system for the beam-transport field in the induction linac is presented. The system consists of a supervisory PC and single chip units built in the current regulators for the magnets connected via RS-485. The profile of the transport field is manipulated accurately by presetting and monitoring the currents through 12 bits A/D and D/A. Any faults of the regulators can be found in advance by the warning system. The optimum field profile may be preset automatically according to the measured beam characterization given an algorithm to the supervisory PC. The system has been used to operate the injector (2 MeV, 3 kA, 10 regulators) for more than one year and proved to be reliable, use-friendly

  4. Use of an optical digital reader for establishing criterion of quality control in clinical beams

    International Nuclear Information System (INIS)

    Genis S, R.

    1998-01-01

    The goal of this work is to present a procedure for realizing the control of the clinical radiation fields through typical radiographic film of verification in radiotherapy and showing the results of the analysis carried out in the expositions of reference fields for photons and electrons using an optical digital reader of high resolution (600 x 1200 dpi) named scanner and a computer program for images edition. It was possible to obtain the quantification of the following parameters: alinement of the radiation beam with the luminous beam, homogeneity or levelling of the radiation field, and self symmetry with respect to the center of the luminous field. With the purpose to compare the results versus an usual method it was realized measurements of the same images with a luminous photo densitometer with 1 mm collimation window. (Author)

  5. Synchronization and Control of Halo-Chaos in Beam Transport Network with Small World Topology

    International Nuclear Information System (INIS)

    Liu Qiang; Fang Jinqing; Li Yong

    2007-01-01

    The synchronous conditions of two kinds of the small-world (SW) network are studied. The small world topology can affect on dynamical behaviors of the beam transport network (BTN) largely, if the BTN is constructed with the SW topology, the global linear coupling and special linear feedback can realize the synchronization control of beam halo-chaos as well as periodic state in the BTN with the SW topology, respectively. This important result can provide an effective way for the experimental study and the engineering design of the BTN in the high-current accelerator driven radioactive clean nuclear power systems, and may have potential use in prospective applications for halo-chaos secure communication.

  6. Atomic layer deposition of HfO2 on graphene through controlled ion beam treatment

    International Nuclear Information System (INIS)

    Kim, Ki Seok; Oh, Il-Kwon; Jung, Hanearl; Kim, Hyungjun; Yeom, Geun Young; Kim, Kyong Nam

    2016-01-01

    The polymer residue generated during the graphene transfer process to the substrate tends to cause problems (e.g., a decrease in electron mobility, unwanted doping, and non-uniform deposition of the dielectric material). In this study, by using a controllable low-energy Ar + ion beam, we cleaned the polymer residue without damaging the graphene network. HfO 2 grown by atomic layer deposition on graphene cleaned using an Ar + ion beam showed a dense uniform structure, whereas that grown on the transferred graphene (before Ar + ion cleaning) showed a non-uniform structure. A graphene–HfO 2 –metal capacitor fabricated by growing 20-nm thick HfO 2 on graphene exhibited a very low leakage current (<10 −11 A/cm 2 ) for Ar + ion-cleaned graphene, whereas a similar capacitor grown using the transferred graphene showed high leakage current.

  7. On finding the analytic dependencies of the external field potential on the control function when optimizing the beam dynamics

    Science.gov (United States)

    Ovsyannikov, A. D.; Kozynchenko, S. A.; Kozynchenko, V. A.

    2017-12-01

    When developing a particle accelerator for generating the high-precision beams, the injection system design is of importance, because it largely determines the output characteristics of the beam. At the present paper we consider the injection systems consisting of electrodes with given potentials. The design of such systems requires carrying out simulation of beam dynamics in the electrostatic fields. For external field simulation we use the new approach, proposed by A.D. Ovsyannikov, which is based on analytical approximations, or finite difference method, taking into account the real geometry of the injection system. The software designed for solving the problems of beam dynamics simulation and optimization in the injection system for non-relativistic beams has been developed. Both beam dynamics and electric field simulations in the injection system which use analytical approach and finite difference method have been made and the results presented in this paper.

  8. Concept Modelling of Vehicle Joints and Beam-Like Structures through Dynamic FE-Based Methods

    Directory of Open Access Journals (Sweden)

    G. De Gaetano

    2014-01-01

    Full Text Available This paper presents dynamic methodologies able to obtain concept models of automotive beams and joints, which compare favourably with the existing literature methods, in terms of accuracy, easiness of implementation, and computational loads. For the concept beams, the proposed method is based on a dynamic finite element (FE approach, which estimates the stiffness characteristics of equivalent 1D beam elements using the natural frequencies, computed by a modal analysis of the detailed 3D FE model of the structure. Concept beams are then connected to each other by a concept joint, which is obtained through a dynamic reduction technique that makes use of its vibration normal modes. The joint reduction is improved through the application of a new interface beam-to-joint element, able to interpolate accurately the nodal displacements of the outer contour of the section, to obtain displacements and rotations of the central connection node. The proposed approach is validated through an application case that is typical in vehicle body engineering: the analysis of a structure formed by three spot-welded thin-walled beams, connected by a joint.

  9. Piezoelectric-based smart sensing system for I-beam structural health monitoring

    Science.gov (United States)

    Zhang, Chen; Zhang, Haifeng; Yu, Tzuyang; Wang, Xingwei

    2016-04-01

    In recent decades, the I-beam has become one of the most important engineering structural components being applied in areas such as mechanical, civil, and constructional engineering. To ensure safety and proper maintenance, an effective and accurate structural health monitoring method/system for I-beams is urgently needed. This paper proposes a smart sensing system for I-beam crack detection that is based on the energy diffusivity (attenuation) between two individual piezoelectric transducers (PZTs). Sensor (one of the PZTs) responses are analyzed and applied to characterize the health status of the I-beam. Lab experiments are carried out for effective evaluation of this approach in structural health monitoring. The characteristics of crack distribution are studied by calculating and analyzing the energy diffusivity variation of the sensor responses to artificially cuttings to the I-beam. Moreover, instead of utilizing an actuator and a sensor, the system employs a couple of PZTs sensors, which offer the potential for in-field, in situ sensing with the sensor arrays. This smart sensing system can be applied in railway, metro, and iron-steel structures for I-beam health monitoring applications.

  10. Investigation based on nano-electromechanical system double Si3N4 resonant beam pressure sensor.

    Science.gov (United States)

    Yang, Chuan; Guo, Can; Yuan, Xiaowei

    2011-12-01

    This paper presents a type of NEMS (Nano-Electromechanical System) double Si3N4 resonant beams pressure sensor. The mathematical models are established in allusion to the Si3N4 resonant beams and pressure sensitive diaphragm. The distribution state of stress has been analyzed theoretically based on the mathematical model of pressure sensitive diaphragm; from the analysis result, the position of the Si3N4 resonant beams above the pressure sensitive diaphragm was optimized and then the dominance observed after the double resonant beams are adopted is illustrated. From the analysis result, the position of the Si3N4 resonant beams above the pressure sensitive diaphragm is optimized, illustrating advantages in the adoption of double resonant beams. The capability of the optimized sensor was generally analyzed using the ANSYS software of finite element analysis. The range of measured pressure is 0-400 Kpa, the coefficient of linearity correlation is 0.99346, and the sensitivity of the sensor is 498.24 Hz/Kpa, higher than the traditional sensors. Finally the processing techniques of the sensor chip have been designed with sample being successfully processed.

  11. Quantitative image quality evaluation for kV cone-beam CT-based IGRT

    International Nuclear Information System (INIS)

    Lim, S Y; Zin, Hafiz M

    2017-01-01

    The objective of this study is to quantitatively evaluate the image quality of a kV cone-beam CT-based IGRT system (Elekta, XVI) using two commercial CT image quality phantoms, Catphan-600 and CIRS-062QA. Both phantoms consist of similar image quality test modules (uniformity, CT linearity and spatial resolution) but each phantom has different diameter and test pattern design. Each test module was imaged separately using an optimised cone-beam CT imaging parameter. The quality metrics of the reconstructed images were analysed using algorithms developed with MatLab. The image uniformity and the spatial resolution measured with Catphan were of 4% and 40% greater respectively, compared to those measured with CIRS phantom. The differences were due to the beam scattering and hardening originated from the CIRS phantom holder. The contrast-to-noise ratio (CNR) values measured with CIRS phantom were at least 2% higher than that of Catphan. The diameter of CIRS phantom is smaller and resulted in lower beam attenuation. The quantitative image quality assessment algorithms developed for both phantoms provided a phantom-specific set of reference values for a cone-beam CT imaging system as recommended by AAPM TG-142. Further investigation will be performed to resolve beam hardening issue arising from the CIRS phantom holder. (paper)

  12. Dosimetric study of RapidArc plans with flattened beam (FB and flattening filter-free (FFF beam for localized prostate cancer based on physical indices

    Directory of Open Access Journals (Sweden)

    Birendra Kumar Rout

    2014-12-01

    Full Text Available Purpose: To identify the continual diversity between flattening photon beam (FB and Flattening Filter Free (FFF photon beams for localized prostate cancer; and to determine potential benefits and drawbacks of using unflattened beam for this type of treatment.Methods: Eight prostate cases including seminal vesicles selected for this study. The primary planning target volume (PTVP and boost planning target volume (PTVB were contoured. The total prescription dose was 78 Gy (56 Gy to PTVP and an additional 22 Gy to PTVB. For all cases, treatment plans using 6MV with FB and FFF beams with identical dose-volume constraints, arc angles and number of arcs were developed. The dose volume histograms for both techniques were compared for primary target volume and critical structures.Results: A low Sigma index (FFF: 1.65 + 0.361; FB: 1.725 + 0.39 indicating improved dose homogeneity in FFF beam. Conformity index (FFF: 0.994 + 0.01; FB: 0.993 + 0.01 is comparable for both techniques. Minimal difference of Organ at risk mean dose was observed. Normal tissue integral dose in FB plan resulted 1.5% lower than FFF plan. All the plans displayed significant increase (1.18 times for PTVP and 1.11 for PTBB in the average number of necessary MU with FFF beam.Conclusion: Diversity between FB and FFF beam plans were found. FFF beam accelerator has been utilized to develop clinically acceptable Rapid Arc treatment plans for prostate cancer with 6 MV.---------------------------------Cite this article as: Rout BK, Muralidhar KR, Ali M, Shekar MC, Kumar A. Dosimetric study of RapidArc plans with flattened beam (FB and flattening filter-free (FFF beam for localized prostate cancer based on physical indices. Int J Cancer Ther Oncol 2014; 2(4:02046.  DOI: 10.14319/ijcto.0204.6

  13. The study of laser beam riding guided system based on 980nm diode laser

    Science.gov (United States)

    Qu, Zhou; Xu, Haifeng; Sui, Xin; Yang, Kun

    2015-10-01

    With the development of science and technology, precision-strike weapons has been considered to be important for winning victory in military field. Laser guidance is a major method to execute precision-strike in modern warfare. At present, the problems of primary stage of Laser guidance has been solved with endeavors of countries. Several technical aspects of laser-beam riding guided system have been mature, such as atmosphere penetration of laser beam, clutter inhibition on ground, laser irradiator, encoding and decoding of laser beam. Further, laser beam quality, equal output power and atmospheric transmission properties are qualified for warfare situation. Riding guidance instrument is a crucial element of Laser-beam riding guided system, and is also a vital element of airborne, vehicle-mounted and individual weapon. The optical system mainly consist of sighting module and laser-beam guided module. Photoelectric detector is the most important sensing device of seeker, and also the key to acquire the coordinate information of target space. Currently, in consideration of the 1.06 u m of wavelength applied in all the semi-active laser guided weapons systems, lithium drifting silicon photodiode which is sensitive to 1.06 u m of wavelength is used in photoelectric detector. Compared to Solid and gas laser, diode laser has many merits such as small volume, simple construction, light weight, long life, low lost and easy modulation. This article introduced the composition and operating principle of Laser-beam riding guided system based on 980 nm diode laser, and made a analysis of key technology; for instance, laser irradiator, modulating disk of component, laser zooming system. Through the use of laser diode, Laser-beam riding guided system is likely to have smaller shape and very light.

  14. Beam Structure Damage Identification Based on BP Neural Network and Support Vector Machine

    Directory of Open Access Journals (Sweden)

    Bo Yan

    2014-01-01

    Full Text Available It is not easy to find marine cracks of structures by directly manual testing. When the cracks of important components are extended under extreme offshore environment, the whole structure would lose efficacy, endanger the staff’s safety, and course a significant economic loss and marine environment pollution. Thus, early discovery of structure cracks is very important. In this paper, a beam structure damage identification model based on intelligent algorithm is firstly proposed to identify partial cracks in supported beams on ocean platform. In order to obtain the replacement mode and strain mode of the beams, the paper takes simple supported beam with single crack and double cracks as an example. The results show that the difference curves of strain mode change drastically only on the injured part and different degrees of injury would result in different mutation degrees of difference curve more or less. While the model based on support vector machine (SVM and BP neural network can identify cracks of supported beam intelligently, the methods can discern injured degrees of sound condition, single crack, and double cracks. Furthermore, the two methods are compared. The results show that the two methods presented in the paper have a preferable identification precision and adaptation. And damage identification based on support vector machine (SVM has smaller error results.

  15. Design and Performance of the H_infinity Controller for the Beam-Waveguide Antenna

    Science.gov (United States)

    Gawronski, W.

    2011-02-01

    The linear-quadratic-Gaussian (LQG) controllers are currently implemented at the beam-waveguide (BWG) antennas. Each BWG antenna has a different set of LQG coefficients, obtained by tuning and testing each controller individually. Individual coefficients for each antenna are necessary, since the antenna dynamics are not identical and the derivation of the LQG coefficients is a labor-intensive process. Hence, the process could be simplified by using single set of coefficients for all BWG antennas. The purpose of the work reported here is to develop a single set of servo coefficients for all BWG antennas. This is achieved by using the H_infinity controller approach and a robust design technique. In this article, the analysis of the H_infinity controller was performed, and the results obtained (by executing over 10,000 Monte Carlo simulations) showed that it is feasible to use a single set of the H_infinity controller coefficients at all BWG antennas, and that the H_infinity controller performance is similar to or exceeds the "standard" LQG controller performance, i.e., except for the DSS-25 antenna controller performance. Note that the latter controller was derived exceptionally strong. At the remaining antennas, the controller coefficients are weaker, and they represent the "standard" LQG performance. This approach simplifies the development of the controller coefficients for BWG antennas, and simplifies the servo performance evaluation, since the performance should be similar for all six BWG antennas.

  16. Simulation of electron beam from two strip electron guns and control of power density by rotation of gun

    International Nuclear Information System (INIS)

    Sahu, G K; Baruah, S; Thakur, K B

    2012-01-01

    Electron beam is preferably used for large scale evaporation of refractory materials. Material evaporation from a long and narrow source providing a well collimated wedge shaped atomic beam has applications in isotopic purification of metals relevant to nuclear industry. The electron beam from an electron gun with strip type filament provides a linear heating source. However, the high power density of the electron beam can lead to turbulence of the melt pool and undesirable splashing of molten metal. For obtaining quiet surface evaporation, the linear electron beam is generally scanned along its length. To further reduce the power density to maintain quiet evaporation the width of the vapour source can be controlled by rotating the electron gun on its plane, thereby scanning an inclined beam over the molten pool. The rotation of gun has further advantages. When multiple strip type electron guns are used for scaling up evaporation length, a dark zone appears between two beams due to physical separation of adjacent guns. This dark zone can be reduced by rotating the gun and thereby bringing two adjacent beams closer. The paper presented here provides the simulation results of the electron beam trajectory and incident power density originating from two strip electron guns by using in-house developed code. The effect of electron gun rotation on the electron beam trajectory and power density is studied. The simulation result is experimentally verified with the image of molten pool and heat affected zone taken after experiment. This technique can be gainfully utilized in controlling the time averaged power density of the electron beam and obtaining quiet evaporation from the metal molten pool.

  17. Structure and organization of automation subsystem for control of beam extraction from a fast-cycling synchrotron

    International Nuclear Information System (INIS)

    Agababyan, A.G.; Ananyan, S.G.; Grigiryan, V.G.

    1989-01-01

    The status of development of an automation subsystem for control of beam extraction from the Erevan synchrotron is described. The hardware complex of the subsystem contains the RPT-80 microcomputer, seven units of automated control for the beam extraction channel, a timer unit for synchronization of the accelerator output devices, a unit for monitoring status signals, an ADS, an interface with the synchrotron, a commutation line between RPT80 and the host ES1010 computer. As a result pilot operation the beam energy spread instability has been reduced 15 times. 5 refs.; 1 fig

  18. Integrating supervision, control and data acquisition—The ITER Neutral Beam Test Facility experience

    Energy Technology Data Exchange (ETDEWEB)

    Luchetta, A., E-mail: adriano.luchetta@igi.cnr.it; Manduchi, G.; Taliercio, C.; Breda, M.; Capobianco, R.; Molon, F.; Moressa, M.; Simionato, P.; Zampiva, E.

    2016-11-15

    Highlights: • The paper describes the experience gained in the integration of different systems for the control and data acquisition system of the ITER Neutral Beam Test Facility. • It describes the way the different frameworks have been integrated. • It reports some lessons learnt during system integration. • It reports some authors’ considerations about the development the ITER CODAC. - Abstract: The ITER Neutral Beam (NBI) Test Facility, under construction in Padova, Italy consists in the ITER full scale ion source for the heating neutral beam injector, referred to as SPIDER, and the full size prototype injector, referred to as MITICA. The Control and Data Acquisition System (CODAS) for SPIDER has been developed and is going to be in operation in 2016. The system is composed of four main components: Supervision, Slow Control, Fast Control and Data Acquisition. These components interact with each other to carry out the system operation and, since they represent a common pattern in fusion experiments, software frameworks have been used for each (set of) component. In order to reuse as far as possible the architecture developed for SPIDER, it is important to clearly define the boundaries and the interfaces among the system components so that the implementation of any component can be replaced without affecting the overall architecture. This work reports the experience gained in the development of SPIDER components, highlighting the importance in the definition of generic interfaces among component, showing how the specific solutions have been adapted to such interfaces and suggesting possible approaches for the development of other ITER subsystems.

  19. Data correlation based noise level estimation for cone beam projection data.

    Science.gov (United States)

    Bai, Ti; Yan, Hao; Ouyang, Luo; Staub, David; Wang, Jing; Jia, Xun; Jiang, Steve B; Mou, Xuanqin

    2017-01-01

    In regularized iterative reconstruction algorithms, the selection of regularization parameter depends on the noise level of cone beam projection data. Our aim is to propose an algorithm to estimate the noise level of cone beam projection data. We first derived the data correlation of cone beam projection data in the Fourier domain, based on which, the signal and the noise were decoupled. Then the noise was extracted and averaged for estimation. An adaptive regularization parameter selection strategy was introduced based on the estimated noise level. Simulation and real data studies were conducted for performance validation. There exists an approximately zero-energy double-wedge area in the 3D Fourier domain of cone beam projection data. As for the noise level estimation results, the averaged relative errors of the proposed algorithm in the analytical/MC/spotlight-mode simulation experiments were 0.8%, 0.14% and 0.24%, respectively, and outperformed the homogeneous area based as well as the transformation based algorithms. Real studies indicated that the estimated noise levels were inversely proportional to the exposure levels, i.e., the slopes in the log-log plot were -1.0197 and -1.049 with respect to the short-scan and half-fan modes. The introduced regularization parameter selection strategy could deliver promising reconstructed image qualities. Based on the data correlation of cone beam projection data in Fourier domain, the proposed algorithm could estimate the noise level of cone beam projection data accurately and robustly. The estimated noise level could be used to adaptively select the regularization parameter.

  20. Fuzzy logic based robotic controller

    Science.gov (United States)

    Attia, F.; Upadhyaya, M.

    1994-01-01

    Existing Proportional-Integral-Derivative (PID) robotic controllers rely on an inverse kinematic model to convert user-specified cartesian trajectory coordinates to joint variables. These joints experience friction, stiction, and gear backlash effects. Due to lack of proper linearization of these effects, modern control theory based on state space methods cannot provide adequate control for robotic systems. In the presence of loads, the dynamic behavior of robotic systems is complex and nonlinear, especially where mathematical modeling is evaluated for real-time operators. Fuzzy Logic Control is a fast emerging alternative to conventional control systems in situations where it may not be feasible to formulate an analytical model of the complex system. Fuzzy logic techniques track a user-defined trajectory without having the host computer to explicitly solve the nonlinear inverse kinematic equations. The goal is to provide a rule-based approach, which is closer to human reasoning. The approach used expresses end-point error, location of manipulator joints, and proximity to obstacles as fuzzy variables. The resulting decisions are based upon linguistic and non-numerical information. This paper presents a solution to the conventional robot controller which is independent of computationally intensive kinematic equations. Computer simulation results of this approach as obtained from software implementation are also discussed.

  1. On-column refractive-index detection based on retroreflected beam interference for capillary electrophoresis.

    Science.gov (United States)

    Deng, Y; Li, B

    1998-02-20

    A novel refractive-index detection scheme used for capillary electrophoresis detection, based on the interference of two retroreflected beams from the outer surface of a capillary tube illuminated by a focused laser beam, is described. A theoretical description and experimental measurement of the intensity profile of the interference fringe pattern in the detection plane are presented. The factors that limit the sensitivity of the proposed refractive-index detection scheme are discussed and compared with the transmitted beam interference and backscatter-based refractive-index detection configurations. The proposed refractive-index detector was used successfully for detection of capillary electrophoresis separations of saccharose, maltose, and lactose with a capillary tube of 50-mum inner diameter and a simple experimental setup.

  2. Development of educational software for beam loading analysis using pen-based user interfaces

    Directory of Open Access Journals (Sweden)

    Yong S. Suh

    2014-01-01

    Full Text Available Most engineering software tools use typical menu-based user interfaces, and they may not be suitable for learning tools because the solution processes are hidden and students can only see the results. An educational tool for simple beam analyses is developed using a pen-based user interface with a computer so students can write and sketch by hand. The geometry of beam sections is sketched, and a shape matching technique is used to recognize the sketch. Various beam loads are added by sketching gestures or writing singularity functions. Students sketch the distributions of the loadings by sketching the graphs, and they are automatically checked and the system provides aids in grading the graphs. Students receive interactive graphical feedback for better learning experiences while they are working on solving the problems.

  3. Polarization Beam Splitter Based on a Self-Collimation Michelson Interferometer in a Silicon Photonic Crystal

    International Nuclear Information System (INIS)

    Chen Xi-Yao; Lin Gui-Min; Li Jun-Jun; Xu Xiao-Fu; Jiang Jun-Zhen; Qiang Ze-Xuan; Qiu Yi-Shen; Li Hui

    2012-01-01

    A polarization beam splitter based on a self-collimation Michelson interferometer (SMI) in a hole-type silicon photonic crystal is proposed and numerically demonstrated. Utilizing the polarization dependence of the transmission spectra of the SMI and polarization peak matching method, the SMI can work as a polarization beam splitter (PBS) by selecting an appropriate path length difference in the structure. Based on its novel polarization beam splitting mechanics, the polarization extinction ratios (PERs) for TM and TE modes are as high as 18.4 dB and 24.3 dB, respectively. Since its dimensions are only several operating wavelengths, the PBS may have practical applications in photonic integrated circuits. (fundamental areas of phenomenology(including applications))

  4. Development of a beam test telescope based on the Alibava readout system

    International Nuclear Information System (INIS)

    Marco-Hernandez, R

    2011-01-01

    A telescope for a beam test have been developed as a result of a collaboration among the University of Liverpool, Centro Nacional de Microelectronica (CNM) of Barcelona and Instituto de Fisica Corpuscular (IFIC) of Valencia. This system is intended to carry out both analogue charge collection and spatial resolution measurements with different types of microstrip or pixel silicon detectors in a beam test environment. The telescope has four XY measurement as well as trigger planes (XYT board) and it can accommodate up to twelve devices under test (DUT board). The DUT board uses two Beetle ASICs for the readout of chilled silicon detectors. The board could operate in a self-triggering mode. The board features a temperature sensor and it can be mounted on a rotary stage. A peltier element is used for cooling the DUT. Each XYT board measures the track space points using two silicon strip detectors connected to two Beetle ASICs. It can also trigger on the particle tracks in the beam test. The board includes a CPLD which allows for the synchronization of the trigger signal to a common clock frequency, delaying and implementing coincidence with other XYT boards. An Alibava mother board is used to read out and to control each XYT/DUT board from a common trigger signal and a common clock signal. The Alibava board has a TDC on board to have a time stamp of each trigger. The data collected by each Alibava board is sent to a master card by means of a local data/address bus following a custom digital protocol. The master board distributes the trigger, clock and reset signals. It also merges the data streams from up to sixteen Alibava boards. The board has also a test channel for testing in a standard mode a XYT or DUT board. This board is implemented with a Xilinx development board and a custom patch board. The master board is connected with the DAQ software via 100M Ethernet. Track based alignment software has also been developed for the data obtained with the DAQ software.

  5. ECR ion source based low energy ion beam facility

    Indian Academy of Sciences (India)

    The extraction of the positive ions from the plasma is done by polarizing the source at a positive potential with respect to ground and pulling ... electrostatic quadrupoles, Faraday cups etc. are controlled via the serial ports. Field point modules are used for AD and DA conversions. The software is written in LabView for easy.

  6. ECR ion source based low energy ion beam facility

    Indian Academy of Sciences (India)

    All the electronic and vacuum systems related to the ECR source including 10 GHz ultra high frequency (UHF) transmitter, high voltage power supplies for extractor and Einzel lens are placed on a high voltage platform. All the equipments are controlled using a personal computer at ground potential through optical fibers for ...

  7. Development of beam monitoring system for proton pencil beam scanning using fiber-optic radiation sensor

    Science.gov (United States)

    Son, Jaeman; Koo, Jihye; Moon, Sunyoung; Yoon, Myonggeun; Jeong, Jonghwi; Kim, Sun-Young; Lim, Youngkyung; Lee, Se Byeong; Shin, Dongho; Kim, Meyoung; Kim, Dongwook

    2017-10-01

    We aimed to develop a beam monitoring system based on a fiber-optic radiation sensor (FORS), which can be used in real time in a beam control room, to monitor a beam in proton therapy, where patients are treated using a pencil beam scanning (PBS) mode, by measuring the beam spot width (BSW) and beam spot position (BSP) of the PBS. We developed two-dimensional detector arrays to monitor the PBS beam in the beam control room. We measured the BSW for five energies of the PBS beam and compared the measurements with those of Lynx and EBT3 film. In order to confirm the BSP, we compared the BSP values of the PBS calculated from radiation treatment planning (RTP), to five BSP values measured using FORS at 224.2 MeV. When comparing BSW values obtained using developed monitoring system to the measurements obtained using commercial EBT3 film, the average difference in BSW value of the PBS beam was 0.1 ± 0.1 mm. In the comparison of BSW values with the measurements obtained using Lynx, the average difference was 0.2 ± 0.1 mm. When comparing BSP measurements to the values calculated from RTP, the average difference was 0.4 ± 0.2 mm. The study results confirmed that the developed FORS-based beam monitoring system can monitor a PBS beam in real time in a beam control room, where proton beam is controlled for the patient.

  8. Performance Analysis of a Threshold-Based Parallel Multiple Beam Selection Scheme for WDM FSO Systems

    KAUST Repository

    Nam, Sung Sik

    2018-04-09

    In this paper, we statistically analyze the performance of a threshold-based parallel multiple beam selection scheme for a free-space optical (FSO) based system with wavelength division multiplexing (WDM) in cases where a pointing error has occurred under independent identically distributed Gamma-Gamma fading conditions. To simplify the mathematical analysis, we additionally consider Gamma turbulence conditions, which are a good approximation of Gamma-Gamma distribution. Specifically, we statistically analyze the characteristics in operation under conventional detection schemes (i.e., heterodyne detection (HD) and intensity modulation/direct detection (IM/DD) techniques) for both adaptive modulation (AM) case in addition to non-AM case (i.e., coherent/non-coherent binary modulation). Then, based on the statistically derived results, we evaluate the outage probability of a selected beam, the average spectral efficiency (ASE), the average number of selected beams (ANSB) and the average bit error rate (BER). Selected results show that we can obtain higher spectral efficiency and simultaneously reduce the potential for increasing the complexity of implementation caused by applying the selection-based beam selection scheme without considerable performance loss. Especially for the AM case, the ASE can be increased further compared to the non- AM cases. Our derived results based on the Gamma distribution as an approximation of the Gamma-Gamma distribution can be used as approximated performance measure bounds, especially, they may lead to lower bounds on the approximated considered performance measures.

  9. Considerations on Beam Quality Control in MIT X-Ray FEL

    CERN Document Server

    Wang, Dong; Graves, William; Huang, Gang; Wang, Defa; Wu, Juhao; Zwart, Townsend

    2005-01-01

    The next generation of x-ray FEL requires very high quality electron beams for producing unprecedented x-ray radiations. In proposed x-ray FEL facilities, especially those that use multi-stage high gain high harmonic (HGHG) principle to obtain coherence in both transverse and longitudinal dimensions, the arrival timing of electron bunches must be very precise to ensure the seed laser overlap the desired sections of the electron bunch. A scheme is proposed to achieve 10s fs level of arrival timing control level.

  10. Controlling laser ablation plasma with external electrodes. Application to sheath dynamics study and beam physics

    International Nuclear Information System (INIS)

    Isono, Fumika; Nakajima, Mitsuo; Hasegawa, Jun; Kawamura, Tohru; Horioka, Kazuhiko

    2013-01-01

    The potential of laser ablation plasma was controlled successfully by using external ring electrodes. We found that an electron sheath is formed at the plasma boundary, which plays an important role in the potential formation. When the positively biased plasma reaches a grounded grid, electrons in the plasma are turned away and ions are accelerated, which leads to the formation of a virtual anode between the grid and an ion probe. We think that this device which can raise the plasma potential up to order of kV can be applied to the study of sheath dynamics and to a new type of ion beam extraction. (author)

  11. A Cherenkov-based Beam Loss Scintillator system for beam, background and online luminosity monitoring at the LHCb experiment at CERN

    CERN Document Server

    Alessio, F; Jacobsson, R

    2013-01-01

    The installation of a scintillator-based system in the LHCb cavern was initially proposed in order to observe injection problems around the LHCb interaction region. Thanks to the fact that LHCb had already developed a custom-made electronics board (BPIM) for the LHCb beam pickups and global LHCb timing monitoring, a complete, inexpensive but flexible and robust system was quickly developed and installed few cm from the beam pipe just in front of the LHCb VELO detector in time for the very first beams injected in the LHC. The current and final system – commonly referred to as Beam Loss Scintillator (BLS) system - ultimately played a central role in the fast beam, background and online luminosity monitoring at LHCb. In this paper, the features of the detector – based on quartz radiator and Cherenkov light - are described, including the functionalities that the system acquired during the proton-proton physics programmes in 2009- 2013 thanks to its flexibility, reliability and sensitivity to beam hal...

  12. Leveraging Technology in Campus Change Initiatives: A Practice Brief Based on BEAMS Project Outcomes

    Science.gov (United States)

    Chough, Alex

    2008-01-01

    During 2003-07, the Building Engagement and Attainment for Minority Students (BEAMS) project fostered data-based campus change initiatives at more than 100 four-year Historically Black, Hispanic-Serving, and Tribal colleges and universities to increase student engagement and learning. This brief provides an overview of technology-driven strategies…

  13. Registration-based Reconstruction of Four-dimensional Cone Beam Computed Tomography

    DEFF Research Database (Denmark)

    Christoffersen, Christian; Hansen, David Christoffer; Poulsen, Per Rugaard

    2013-01-01

    We present a new method for reconstruction of four-dimensional (4D) cone beam computed tomography from an undersampled set of X-ray projections. The novelty of the proposed method lies in utilizing optical flow based registration to facilitate that each temporal phase is reconstructed from the full...

  14. Design of a beam shaping assembly for an accelerator-based BNCT system

    International Nuclear Information System (INIS)

    Stichelbaut, F.; Forton, E.; Jongen, Y.

    2006-01-01

    A complete BNCT system based on a high-intensity proton accelerator is developed by the IBA company. The neutron beam is produced via the 7 Li(p,n) 7 Be reaction using a solid lithium target. The neutron energy spectrum is tailored with a beam shaping assembly surrounding the target. This device is the object of an extensive R and D project and is fully designed with the Monte Carlo simulation code MCNPX. The emphasis is put on the treatment quality, notably the radiation dose at the skin level, and the achievable neutron flux. (author)

  15. Ion beam-based studies for tribological phenomena

    Science.gov (United States)

    Racolta, P. M.; Popa-Simil, L.; Alexandreanu, B.

    1996-06-01

    Custom-designed experiments based on the Thin Layer Activation technique (TLA) were completed, providing information on the wear level of some engine components with additional data on transfer and adhesion of material between metallic friction couples using the RBS method. RBS experimental results concerning material transfer for a steel-brass friction couple are presented and discussed in the paper. Also, the types and concentrations of the wear products in used lubricant oils were determined by in-air PIXE. A sequential lubricant filtering-based procedure for determining the dimension distribution of the resulting radioactive wear particles by low level γ-spectrometry is presented. Experimental XRF spectra showing the non-homogeneous distribution of the retained waste particles on the filtering paper are shown.

  16. Laser induced breakdown spectroscopy based on single beam splitting and geometric configuration for effective signal enhancement.

    Science.gov (United States)

    Yang, Guang; Lin, Qingyu; Ding, Yu; Tian, Di; Duan, Yixiang

    2015-01-05

    A new laser induced breakdown spectroscopy (LIBS) based on single-beam-splitting (SBS) and proper optical geometric configuration has been initially explored in this work for effective signal enhancement. In order to improve the interaction efficiency of laser energy with the ablated material, a laser beam operated in pulse mode was divided into two streams to ablate/excite the target sample in different directions instead of the conventional one beam excitation in single pulse LIBS (SP-LIBS). In spatial configuration, the laser beam geometry plays an important role in the emission signal enhancement. Thus, an adjustable geometric configuration with variable incident angle between the two splitted laser beams was constructed for achieving maximum signal enhancement. With the optimized angles of 60° and 70° for Al and Cu atomic emission lines at 396.15 nm and 324.75 nm respectively, about 5.6- and 4.8-folds signal enhancements were achieved for aluminum alloy and copper alloy samples compared to SP-LIBS. Furthermore, the temporal analysis, in which the intensity of atomic lines in SP-LIBS decayed at least ten times faster than the SBS-LIBS, proved that the energy coupling efficiency of SBS-LIBS was significantly higher than that of SP-LIBS.

  17. Laser Induced Breakdown Spectroscopy Based on Single Beam Splitting and Geometric Configuration for Effective Signal Enhancement

    Science.gov (United States)

    Yang, Guang; Lin, Qingyu; Ding, Yu; Tian, Di; Duan, Yixiang

    2015-01-01

    A new laser induced breakdown spectroscopy (LIBS) based on single-beam-splitting (SBS) and proper optical geometric configuration has been initially explored in this work for effective signal enhancement. In order to improve the interaction efficiency of laser energy with the ablated material, a laser beam operated in pulse mode was divided into two streams to ablate/excite the target sample in different directions instead of the conventional one beam excitation in single pulse LIBS (SP-LIBS). In spatial configuration, the laser beam geometry plays an important role in the emission signal enhancement. Thus, an adjustable geometric configuration with variable incident angle between the two splitted laser beams was constructed for achieving maximum signal enhancement. With the optimized angles of 60° and 70° for Al and Cu atomic emission lines at 396.15 nm and 324.75 nm respectively, about 5.6- and 4.8-folds signal enhancements were achieved for aluminum alloy and copper alloy samples compared to SP-LIBS. Furthermore, the temporal analysis, in which the intensity of atomic lines in SP-LIBS decayed at least ten times faster than the SBS-LIBS, proved that the energy coupling efficiency of SBS-LIBS was significantly higher than that of SP-LIBS. PMID:25557721

  18. Research of beam hardening correction method for CL system based on SART algorithm

    International Nuclear Information System (INIS)

    Cao Daquan; Wang Yaxiao; Que Jiemin; Sun Cuili; Wei Cunfeng; Wei Long

    2014-01-01

    Computed laminography (CL) is a non-destructive testing technique for large objects, especially for planar objects. Beam hardening artifacts were wildly observed in the CL system and significantly reduce the image quality. This study proposed a novel simultaneous algebraic reconstruction technique (SART) based beam hardening correction (BHC) method for the CL system, namely the SART-BHC algorithm in short. The SART-BHC algorithm took the polychromatic attenuation process in account to formulate the iterative reconstruction update. A novel projection matrix calculation method which was different from the conventional cone-beam or fan-beam geometry was also studied for the CL system. The proposed method was evaluated with simulation data and experimental data, which was generated using the Monte Carlo simulation toolkit Geant4 and a bench-top CL system, respectively. All projection data were reconstructed with SART-BHC algorithm and the standard filtered back projection (FBP) algorithm. The reconstructed images show that beam hardening artifacts are greatly reduced with the SART-BHC algorithm compared to the FBP algorithm. The SART-BHC algorithm doesn't need any prior know-ledge about the object or the X-ray spectrum and it can also mitigate the interlayer aliasing. (authors)

  19. Beam-based model of broad-band impedance of the Diamond Light Source

    Science.gov (United States)

    Smaluk, Victor; Martin, Ian; Fielder, Richard; Bartolini, Riccardo

    2015-06-01

    In an electron storage ring, the interaction between a single-bunch beam and a vacuum chamber impedance affects the beam parameters, which can be measured rather precisely. So we can develop beam-based numerical models of longitudinal and transverse impedances. At the Diamond Light Source (DLS) to get the model parameters, a set of measured data has been used including current-dependent shift of betatron tunes and synchronous phase, chromatic damping rates, and bunch lengthening. A matlab code for multiparticle tracking has been developed. The tracking results and analytical estimations are quite consistent with the measured data. Since Diamond has the shortest natural bunch length among all light sources in standard operation, the studies of collective effects with short bunches are relevant to many facilities including next generation of light sources.

  20. Beam-based model of broad-band impedance of the Diamond Light Source

    Directory of Open Access Journals (Sweden)

    Victor Smaluk

    2015-06-01

    Full Text Available In an electron storage ring, the interaction between a single-bunch beam and a vacuum chamber impedance affects the beam parameters, which can be measured rather precisely. So we can develop beam-based numerical models of longitudinal and transverse impedances. At the Diamond Light Source (DLS to get the model parameters, a set of measured data has been used including current-dependent shift of betatron tunes and synchronous phase, chromatic damping rates, and bunch lengthening. A matlab code for multiparticle tracking has been developed. The tracking results and analytical estimations are quite consistent with the measured data. Since Diamond has the shortest natural bunch length among all light sources in standard operation, the studies of collective effects with short bunches are relevant to many facilities including next generation of light sources.

  1. Study of low energy neutron beam formation based on GEANT4 simulations

    Science.gov (United States)

    Avagyan, R.; Avetisyan, R.; Ivanyan, V.; Kerobyan, I.

    2017-07-01

    The possibility of obtaining thermal/epithermal energy neutron beams using external protons from cyclotron C18/18 is studied based on GEANT4 simulations. This study will be the basis of the Beam Shaped Assembly (BSA) development for future Boron Neutron Capture Therapy (BNCT). Proton induced reactions on 9Be target are considered as a neutron source, and dependence of neutron yield on target thickness is investigated. The problem of reducing the ratio of gamma to neutron yields by inserting a lead sheet after the beryllium target is studied as well. By GEANT4 modeling the optimal thicknesses of 9Be target and lead absorber are determined and the design characteristics of beam shaping assembly, including the materials and thicknesses of reflector and moderator are considered.

  2. Spectrum shaping of accelerator-based neutron beams for BNCT

    CERN Document Server

    Montagnini, B; Esposito, J; Giusti, V; Mattioda, F; Varone, R

    2002-01-01

    We describe Monte Carlo simulations of three facilities for the production of epithermal neutrons for Boron Neutron Capture Therapy (BNCT) and examine general aspects and problems of designing the spectrum-shaping assemblies to be used with these neutron sources. The first facility is based on an accelerator-driven low-power subcritical reactor, operating as a neutron amplifier. The other two facilities have no amplifier and rely entirely on their primary sources, a D-T fusion reaction device and a conventional 2.5 MeV proton accelerator with a Li target, respectively.

  3. Coordinate transformation based cryo-correlative methods for electron tomography and focused ion beam milling

    International Nuclear Information System (INIS)

    Fukuda, Yoshiyuki; Schrod, Nikolas; Schaffer, Miroslava; Feng, Li Rebekah; Baumeister, Wolfgang; Lucic, Vladan

    2014-01-01

    Correlative microscopy allows imaging of the same feature over multiple length scales, combining light microscopy with high resolution information provided by electron microscopy. We demonstrate two procedures for coordinate transformation based correlative microscopy of vitrified biological samples applicable to different imaging modes. The first procedure aims at navigating cryo-electron tomography to cellular regions identified by fluorescent labels. The second procedure, allowing navigation of focused ion beam milling to fluorescently labeled molecules, is based on the introduction of an intermediate scanning electron microscopy imaging step to overcome the large difference between cryo-light microscopy and focused ion beam imaging modes. These methods make it possible to image fluorescently labeled macromolecular complexes in their natural environments by cryo-electron tomography, while minimizing exposure to the electron beam during the search for features of interest. - Highlights: • Correlative light microscopy and focused ion beam milling of vitrified samples. • Coordinate transformation based cryo-correlative method. • Improved correlative light microscopy and cryo-electron tomography

  4. A model-based analysis of a simplified beam-specific dose output in proton therapy with a single-ring wobbling system.

    Science.gov (United States)

    Kase, Yuki; Yamashita, Haruo; Numano, Masumi; Sakama, Makoto; Mizota, Manabu; Maeda, Yoshikazu; Tameshige, Yuji; Murayama, Shigeyuki

    2015-01-07

    In radiation therapy, it is necessary to preset a monitor unit in an irradiation control system to deliver a prescribed absolute dose to a reference point in the planning target volume. The purpose of this study was to develop a model-based monitor unit calculation method for proton-beam therapy with a single-ring wobbling system. The absorbed dose at a calibration point per monitor unit had been measured for each beam-specific measurement condition without a patient-specific collimator or range compensator before proton therapeutic irradiation at Shizuoka Cancer Center. In this paper, we propose a simplified dose output model to obtain the output ratio between a beam-specific dose and a reference field dose, from which a monitor unit for the proton treatment could be derived without beam-specific measurements. The model parameters were determined to fit some typical data measured in a proton treatment room, called a Gantry 1 course. Then, the model calculation was compared with 5456 dose output ratios that had been measured for 150-, 190- and 220 MeV therapeutic proton beams in two treatment rooms over the past decade. The mean value and standard deviation of the difference between the measurement and the model calculation were respectively 0.00% and 0.27% for the Gantry 1 course, and -0.25% and 0.35% for the Gantry 2 course. The model calculation was in good agreement with the measured beam-specific doses, within 1%, except for conditions less frequently used for treatment. The small variation for the various beam conditions shows the high long-term reproducibility of the measurement and high degree of compatibility of the two treatment rooms. Therefore, the model was expected to assure the setting value of the dose monitor for treatment, to save the effort required for beam-specific measurement, and to predict the dose output for new beam conditions in the future.

  5. Deflection control of functionally graded material beams with bonded piezoelectric sensors and actuators

    International Nuclear Information System (INIS)

    Gharib, Ahmad; Salehi, Manouchehr; Fazeli, Saeed

    2008-01-01

    An analytical solution is developed for analysis of functionally graded material (FGM) beams containing two layers of piezoelectric material, used as sensor and actuator. The properties of FGM layer are functionally graded in the thickness direction according to the volume fraction power law distribution. The equations of motion are derived by using Hamilton's principle, based on the first-order shear deformation theory. By using a displacement potential function, and assumption of harmonic vibration, the equations of motion have been solved analytically. Finally, the effects of FGM constituent volume fraction in the peak responses for various volume fraction indexes have been graphically illustrated

  6. Artificial intelligence research in particle accelerator control systems for beam line tuning

    Energy Technology Data Exchange (ETDEWEB)

    Pieck, Martin [Los Alamos National Laboratory

    2008-01-01

    Tuning particle accelerators is time consuming and expensive, with a number of inherently non-linear interactions between system components. Conventional control methods have not been successful in this domain and the result is constant and expensive monitoring of the systems by human operators. This is particularly true for the start-up and conditioning phase after a maintenance period or an unexpected fault. In turn, this often requires a step-by-step restart of the accelerator. Surprisingly few attempts have been made to apply intelligent accelerator control techniques to help with beam tuning, fault detection, and fault recovery problems. The reason for that might be that accelerator facilities are rare and difficult to understand systems that require detailed expert knowledge about the underlying physics as well as months if not years of experience to understand the relationship between individual components, particularly if they are geographically disjoint. This paper will give an overview about the research effort in the accelerator community that has been dedicated to the use of artificial intelligence methods for accelerator beam line tuning.

  7. Development of automatic control method for cryopump system for JT-60 neutral beam injector

    International Nuclear Information System (INIS)

    Shibanuma, Kiyoshi; Akino, Noboru; Dairaku, Masayuki; Ohuchi, Yutaka; Shibata, Takemasa

    1991-10-01

    A cryopump system for JT-60 neutral beam injector (NBI) is composed of 14 cryopumps with the largest total pumping speed of 20000 m 3 /s in the world, which are cooled by liquid helium through a long-distance liquid helium transferline of about 500 m from a helium refrigerator with the largest capacity of 3000 W at 3.6 K in Japan. An automatic control method of the cryopump system has been developed and tested. Features of the automatic control method are as follows. 1) Suppression control of the thermal imbalance in cooling-down of the 14 cryopumps. 2) Stable cooling control of the cryopump due to liquid helium supply to six cryopanels by natural circulation in steady-state mode. 3) Stable liquid helium supply control for the cryopumps from the liquid helium dewar in all operation modes of the cryopumps, considering the helium quantities held in respective components of the closed helium loop. 4) Stable control of the helium refrigerator for the fluctuation in thermal load from the cryopumps and the change of operation mode of the cryopumps. In the automatic operation of the cryopump system by the newly developed control method, the cryopump system including the refrigerator was stably operated for all operation modes of the cryopumps, so that the cool-down of 14 cryopumps was completed in 16 hours from the start of cool-down of the system and the cryopumps was stably cooled by natural circulation cooling in steady-state mode. (author)

  8. Direct atomic fabrication and dopant positioning in Si using electron beams with active real-time image-based feedback.

    Science.gov (United States)

    Jesse, Stephen; Hudak, Bethany M; Zarkadoula, Eva; Song, Jiaming; Maksov, Artem; Fuentes-Cabrera, Miguel; Ganesh, Panchapakesan; Kravchenko, Ivan; Snijders, Panchapakesan C; Lupini, Andrew R; Borisevich, Albina Y; Kalinin, Sergei V

    2018-06-22

    Semiconductor fabrication is a mainstay of modern civilization, enabling the myriad applications and technologies that underpin everyday life. However, while sub-10 nanometer devices are already entering the mainstream, the end of the Moore's law roadmap still lacks tools capable of bulk semiconductor fabrication on sub-nanometer and atomic levels, with probe-based manipulation being explored as the only known pathway. Here we demonstrate that the atomic-sized focused beam of a scanning transmission electron microscope can be used to manipulate semiconductors such as Si on the atomic level, inducing growth of crystalline Si from the amorphous phase, reentrant amorphization, milling, and dopant front motion. These phenomena are visualized in real-time with atomic resolution. We further implement active feedback control based on real-time image analytics to automatically control the e-beam motion, enabling shape control and providing a pathway for atom-by-atom correction of fabricated structures in the near future. These observations open a new epoch for atom-by-atom manufacturing in bulk, the long-held dream of nanotechnology.

  9. Bulk focused ion beam fabrication with three-dimensional shape control of nanoelectromechanical systems

    International Nuclear Information System (INIS)

    Vick, D; Sauer, V; Freeman, M R; Hiebert, W K; Fraser, A E

    2010-01-01

    Although focused ion beam (FIB) milling has previously been used for fabrication of compliant nanostructures and devices, few instances of FIB nanomachining of such devices out of bulk materials have been reported. We use FIB to fabricate nanoelectromechanical systems (NEMS) devices out of bulk materials. Ion impingement from multiple directions allows sculpting with considerable three-dimensional control of device shape, including tapering and notching. Finite-element modeling of device frequencies agrees with optical interferometric measurements, including for the effect of a localized notch. We envision that bulk FIB fabrication will be useful for NEMS prototyping, milling of tough-to-machine materials and generalized nanostructure fabrication with three-dimensional shape control

  10. Control of natural microorganisms in chamomile (Chamomilla recutita L.) by gamma ray and electron beam irradiation.

    Science.gov (United States)

    Al-Bachir, Mahfouz

    2017-01-01

    Microbial contamination levels and corresponding sensitivities to gamma rays (GR) and elec- tron beam (EB) irradiation were tested in chamomile (Chamomile recutta L.). Chamomile powders were treated with 10 and 20 kGy by GR and EB, respectively. Microbiological and chemical analyses were performed on controls and treated samples immediately after irradiation, and after 12 months of storage. The control samples of chamomile exhibited rather high microbiological contamination, exceeding the levels of 4 log10 CFU g-1   (CFU - colony forming units) reported by national and international authorities as the maximum permissible total count level. Irradiation with GR and EB was found to cause a reduction in microbial contamination proportionate to the dose delivered. The sterilizing effect of EB on microorganisms was higher than the GR one. A dose of 10 kGy of GR and EB significantly (p chamomile powder than gamma irradiation.

  11. Location specific solidification microstructure control in electron beam melting of Ti-6Al-4V

    Energy Technology Data Exchange (ETDEWEB)

    Narra, Sneha P.; Cunningham, Ross; Beuth, Jack; Rollett, Anthony D.

    2018-01-01

    Relationships between prior beta grain size in solidified Ti-6Al-4V and melting process parameters in the Electron Beam Melting (EBM) process are investigated. Samples are built by varying a machine-dependent proprietary speed function to cover the process space. Optical microscopy is used to measure prior beta grain widths and assess the number of prior beta grains present in a melt pool in the raster region of the build. Despite the complicated evolution of beta grain sizes, the beta grain width scales with melt pool width. The resulting understanding of the relationship between primary machine variables and prior beta grain widths is a key step toward enabling the location specific control of as-built microstructure in the EBM process. Control of grain width in separate specimens and within a single specimen is demonstrated.

  12. Cassette-based in-situ TEM sample inspection in the dual-beam FIB

    International Nuclear Information System (INIS)

    Kendrick, A B; Moore, T M; Zaykova-Feldman, L; Amador, G; Hammer, M

    2008-01-01

    A novel method is presented, combining site-specific TEM sample preparation and in-situ STEM analysis in a dual-beam microscope (FIB/SEM) fitted with a chamber mounted nano-manipulator. TEM samples are prepared using a modified in-situ, lift-out method, whereby the samples are thinned and oriented for immediate in-situ STEM analysis using the tilt, translation, and rotation capabilities of a FIB/SEM sample stage, a nano-manipulator, and a novel cassette. This cassette can provide a second tilt axis, orthogonal to the stage tilt axis, so that the STEM image contrast can be optimized to reveal the structural features of the sample (true STEM imaging in the FIB/SEM). The angles necessary for stage rotation and probe shaft rotation are calculated based on the position of the nano-manipulator relative to the stage and door and the stage tilt angle. A FIB/SEM instrument, equipped with a high resolution scanning electron column, can provide sufficiently high image resolution to enable many failure analysis and process control applications to be successfully carried out without requiring the use of a separate dedicated TEM/STEM instrument. The benefits of this novel approach are increased throughput and reduced cost per sample. Comparative analysis of different sample preparation methods is provided, and the STEM images obtained are shown.

  13. A self-adaptive metamaterial beam with digitally controlled resonators for subwavelength broadband flexural wave attenuation

    Science.gov (United States)

    Li, Xiaopeng; Chen, Yangyang; Hu, Gengkai; Huang, Guoliang

    2018-04-01

    Designing lightweight materials and/or structures for broadband low-frequency noise/vibration mitigation is an issue of fundamental importance both practically and theoretically. In this paper, by leveraging the concept of frequency-dependent effective stiffness control, we numerically and experimentally demonstrate, for the first time, a self-adaptive metamaterial beam with digital circuit controlled mechanical resonators for strong and broadband flexural wave attenuation at subwavelength scales. The digital controllers that are capable of feedback control of piezoelectric shunts are integrated into mechanical resonators in the metamaterial, and the transfer function is semi-analytically determined to realize an effective bending stiffness in a quadratic function of the wave frequency for adaptive band gaps. The digital as well as analog control circuits as the backbone of the system are experimentally realized with the guarantee stability of the whole electromechanical system in whole frequency regions, which is the most challenging problem so far. Our experimental results are in good agreement with numerical predictions and demonstrate the strong wave attenuation in almost a three times larger frequency region over the bandwidth of a passive metamaterial. The proposed metamaterial could be applied in a range of applications in the design of elastic wave control devices.

  14. On-chip free beam optics on a polymer-based photonic integration platform.

    Science.gov (United States)

    Happach, M; de Felipe, D; Conradi, H; Friedhoff, V N; Schwartz, E; Kleinert, M; Brinker, W; Zawadzki, C; Keil, N; Hofmann, W; Schell, M

    2017-10-30

    This paper presents on-chip free beam optics on polymer-based photonic components. Due to the circumstance that waveguide-based optics allows no direct beam access we use Gradient index (GRIN) lenses assembled into the chip to collimate the beam from the waveguides. This enables low loss power transmission over a length of 1432 µm. Even though the beam propagates through air it is possible to create a resonator with a wavelength shift of 0.002 nm/°C, hence the allowed deviations from the ITU-T grid (100 GHz) are met for ± 20 °C. In order to guarantee reliable laser stability, it is necessary to implement optical isolators at the output of the laser. This requires the insertion of bulk material into the chip and is realized by a 1050 µm thick coated glass. Due to the large gap of the free-space section, it is possible to combine different resonators together. This demonstrates the feasibility of an integrated wavelength-meter.

  15. Is the Schneiderian membrane thickness affected by periodontal disease? A cone beam computed tomography-based extended case series.

    Science.gov (United States)

    Dagassan-Berndt, Dorothea C; Zitzmann, Nicola U; Lambrecht, J Thomas; Weiger, Roland; Walter, Clemens

    2013-07-01

    The aim was to assess the thickness of Schneiderian membranes (SM) in patients with advanced periodontal disease. 17 dentate patients (DG) scheduled for periodontal surgery on maxillary molars were consecutively recruited and cone beam computed tomographies performed for preoperative diagnosis. Twenty-one patients (EG) requiring cone beam computed tomography-based planning of implant placement in the edentulous posterior maxilla served as controls. Schneiderian membrane thickness measured from cone beam computed tomography was significantly greater in the dentate group compared to the edentulous group, both in the first (p = 0.028) and second (p periodontal destruction (increased probing pocket depth or furcation involvement) were not associated with Schneiderian membrane thickness. Additional findings, such as periapical lesions (p = 0.008), and the distance between root tips and maxillary sinus revealed a significant association (p = 0.036) with Schneiderian membrane thickness. In molar regions with periodontal destruction, Schneiderian membrane thickening occurred, particularly in combination with small bone layers above the root tips or periapical lesions.

  16. Hypofractionated radiotherapy for lung tumors with online cone beam CT guidance and active breathing control

    Science.gov (United States)

    2010-01-01

    Background To study the set-up errors, PTV margin and toxicity of cone beam CT (CBCT) guided hypofractionated radiotherapy with active breathing control (ABC) for patients with non-small cell lung cancer (NSCLC) or metastatic tumors in lung. Methods 32 tumors in 20 patients were treated. Based on the location of tumor, dose per fraction given to tumor was divided into three groups: 12 Gy, 8 Gy and 6 Gy. ABC is applied for every patient. During each treatment, patients receive CBCT scan for online set-up correction. The pre- and post-correction setup errors between fractions, the interfractional and intrafractional, set-up errors, PTV margin as well as toxicity are analyzed. Results The pre-correction systematic and random errors in the left-right (LR), superior-inferior (SI), anterior-posterior (AP) directions were 3.7 mm and 5.3 mm, 3.1 mm and 2.1 mm, 3.7 mm and 2.8 mm, respectively, while the post-correction residual errors were 0.6 mm and 0.8 mm, 0.8 mm and 0.8 mm, 1.2 mm and 1.3 mm, respectively. There was an obvious intrafractional shift of tumor position. The pre-correction PTV margin was 9.5 mm in LR, 14.1 mm in SI and 8.2 mm in AP direction. After CBCT guided online correction, the PTV margin was markedly reduced in all three directions. The post-correction margins ranged 1.5 to 2.1 mm. The treatment was well tolerated by patients, of whom there were 4 (20%) grade1-2 acute pneumonitis, 3 (15%) grade1 acute esophagitis, 2 (10%) grade1 late pneumonitis and 1 (5%) grade 1 late esophagitis. Conclusion The positioning errors for lung SBRT using ABC were significant. Online correction with CBCT image guidance should be applied to reduce setup errors and PTV margin, which may reduce radiotherapy toxicity of tissues when ABC was used. PMID:20187962

  17. Hypofractionated radiotherapy for lung tumors with online cone beam CT guidance and active breathing control

    International Nuclear Information System (INIS)

    Shen, Yali; Zhang, Hong; Wang, Jin; Zhong, Renming; Jiang, Xiaoqing; Xu, Qinfeng; Wang, Xin; Bai, Sen; Xu, Feng

    2010-01-01

    To study the set-up errors, PTV margin and toxicity of cone beam CT (CBCT) guided hypofractionated radiotherapy with active breathing control (ABC) for patients with non-small cell lung cancer (NSCLC) or metastatic tumors in lung. 32 tumors in 20 patients were treated. Based on the location of tumor, dose per fraction given to tumor was divided into three groups: 12 Gy, 8 Gy and 6 Gy. ABC is applied for every patient. During each treatment, patients receive CBCT scan for online set-up correction. The pre- and post-correction setup errors between fractions, the interfractional and intrafractional, set-up errors, PTV margin as well as toxicity are analyzed. The pre-correction systematic and random errors in the left-right (LR), superior-inferior (SI), anterior-posterior (AP) directions were 3.7 mm and 5.3 mm, 3.1 mm and 2.1 mm, 3.7 mm and 2.8 mm, respectively, while the post-correction residual errors were 0.6 mm and 0.8 mm, 0.8 mm and 0.8 mm, 1.2 mm and 1.3 mm, respectively. There was an obvious intrafractional shift of tumor position. The pre-correction PTV margin was 9.5 mm in LR, 14.1 mm in SI and 8.2 mm in AP direction. After CBCT guided online correction, the PTV margin was markedly reduced in all three directions. The post-correction margins ranged 1.5 to 2.1 mm. The treatment was well tolerated by patients, of whom there were 4 (20%) grade1-2 acute pneumonitis, 3 (15%) grade1 acute esophagitis, 2 (10%) grade1 late pneumonitis and 1 (5%) grade 1 late esophagitis. The positioning errors for lung SBRT using ABC were significant. Online correction with CBCT image guidance should be applied to reduce setup errors and PTV margin, which may reduce radiotherapy toxicity of tissues when ABC was used

  18. Hypofractionated radiotherapy for lung tumors with online cone beam CT guidance and active breathing control

    Directory of Open Access Journals (Sweden)

    Wang Xin

    2010-02-01

    Full Text Available Abstract Background To study the set-up errors, PTV margin and toxicity of cone beam CT (CBCT guided hypofractionated radiotherapy with active breathing control (ABC for patients with non-small cell lung cancer (NSCLC or metastatic tumors in lung. Methods 32 tumors in 20 patients were treated. Based on the location of tumor, dose per fraction given to tumor was divided into three groups: 12 Gy, 8 Gy and 6 Gy. ABC is applied for every patient. During each treatment, patients receive CBCT scan for online set-up correction. The pre- and post-correction setup errors between fractions, the interfractional and intrafractional, set-up errors, PTV margin as well as toxicity are analyzed. Results The pre-correction systematic and random errors in the left-right (LR, superior-inferior (SI, anterior-posterior (AP directions were 3.7 mm and 5.3 mm, 3.1 mm and 2.1 mm, 3.7 mm and 2.8 mm, respectively, while the post-correction residual errors were 0.6 mm and 0.8 mm, 0.8 mm and 0.8 mm, 1.2 mm and 1.3 mm, respectively. There was an obvious intrafractional shift of tumor position. The pre-correction PTV margin was 9.5 mm in LR, 14.1 mm in SI and 8.2 mm in AP direction. After CBCT guided online correction, the PTV margin was markedly reduced in all three directions. The post-correction margins ranged 1.5 to 2.1 mm. The treatment was well tolerated by patients, of whom there were 4 (20% grade1-2 acute pneumonitis, 3 (15% grade1 acute esophagitis, 2 (10% grade1 late pneumonitis and 1 (5% grade 1 late esophagitis. Conclusion The positioning errors for lung SBRT using ABC were significant. Online correction with CBCT image guidance should be applied to reduce setup errors and PTV margin, which may reduce radiotherapy toxicity of tissues when ABC was used.

  19. Kr-86 Ion-Beam Irradiation of Hydrated DNA: Free Radical and Unaltered Base Yields

    Science.gov (United States)

    Becker, David; Adhikary, Amitava; Tetteh, Smedley T.; Bull, Arthur W.; Sevilla, Michael D.

    2012-01-01

    This work reports an ESR and product analysis investigation of Kr-86 ion-beam irradiation of hydrated DNA at 77 K. The irradiation results in the formation and trapping of both base radicals and sugar phosphate radicals (DNA backbone radicals). The absolute yields (G, μmol/J) of the base radicals are smaller than the yields found in similarly prepared γ-irradiated DNA samples, and the relative yields of backbone radicals relative to base radicals are much higher than that found in γ-irradiated samples. From these results, we have elaborated our radiation chemical model of the track structure for ion-beam irradiated DNA as it applies to krypton ion-beams. The base radicals, which are trapped as ion radicals or reversibly protonated or deprotonated ion radicals, are formed almost entirely in the track penumbra, a region in which radiation chemical effects are similar to those found in γ-irradiated samples. By comparing the yields of base radicals in ion-beam samples to the yields of the same radicals in γ-irradiated samples, the partition of energy between the low-LET region (penumbra) and the core is experimentally determined. The neutral sugar and other backbone radicals, which are not as susceptible to recombination as are ion radicals, are formed largely in the track core. The backbone radicals show a linear dose response up to very high doses. Unaltered base release yields in Kr-86 irradiated hydrated DNA are equal to sugar radical yields within experimental error limits, consistent with radiation-chemical processes in which all base release originates with sugar radicals. Two phosphorus-centered radicals from fragmentation of the DNA backbone are found in low yields. PMID:23106211

  20. Initial clinical evaluation of PET-based ion beam therapy monitoring under consideration of organ motion.

    Science.gov (United States)

    Kurz, Christopher; Bauer, Julia; Unholtz, Daniel; Richter, Daniel; Herfarth, Klaus; Debus, Jürgen; Parodi, Katia

    2016-02-01

    Intrafractional organ motion imposes considerable challenges to scanned ion beam therapy and demands for a thorough verification of the applied treatment. At the Heidelberg Ion-Beam Therapy Center (HIT), the scanned ion beam delivery is verified by means of postirradiation positron-emission-tomography (PET) imaging. This work presents a first clinical evaluation of PET-based treatment monitoring in ion beam therapy under consideration of target motion. Three patients with mobile liver lesions underwent scanned carbon ion irradiation at HIT and postirradiation PET/CT (x-ray-computed-tomography) imaging with a commercial scanner. Respiratory motion was recorded during irradiation and subsequent image acquisition. This enabled a time-resolved (4D) calculation of the expected irradiation-induced activity pattern and, for one patient where an additional 4D CT was acquired at the PET/CT scanner after treatment, a motion-compensated PET image reconstruction. For the other patients, PET data were reconstructed statically. To verify the treatment, calculated prediction and reconstructed measurement were compared with a focus on the ion beam range. Results in the current three patients suggest that for motion amplitudes in the order of 2 mm there is no benefit from incorporating respiratory motion information into PET-based treatment monitoring. For a target motion in the order of 10 mm, motion-related effects become more severe and a time-resolved modeling of the expected activity distribution can lead to an improved data interpretation if a sufficient number of true coincidences is detected. Benefits from motion-compensated PET image reconstruction could not be shown conclusively at the current stage. The feasibility of clinical PET-based treatment verification under consideration of organ motion has been shown for the first time. Improvements in noise-robust 4D PET image reconstruction are deemed necessary to enhance the clinical potential.

  1. Optimization and evaluation of multiple gating beam delivery in a synchrotron-based proton beam scanning system using a real-time imaging technique.

    Science.gov (United States)

    Yamada, Takahiro; Miyamoto, Naoki; Matsuura, Taeko; Takao, Seishin; Fujii, Yusuke; Matsuzaki, Yuka; Koyano, Hidenori; Umezawa, Masumi; Nihongi, Hideaki; Shimizu, Shinichi; Shirato, Hiroki; Umegaki, Kikuo

    2016-07-01

    To find the optimum parameter of a new beam control function installed in a synchrotron-based proton therapy system. A function enabling multiple gated irradiation in the flat top phase has been installed in a real-time-image gated proton beam therapy (RGPT) system. This function is realized by a waiting timer that monitors the elapsed time from the last gate-off signal in the flat top phase. The gated irradiation efficiency depends on the timer value, Tw. To find the optimum Tw value, gated irradiation efficiency was evaluated for each configurable Tw value. 271 gate signal data sets from 58 patients were used for the simulation. The highest mean efficiency 0.52 was obtained in TW=0.2s. The irradiation efficiency was approximately 21% higher than at TW=0s, which corresponds to ordinary synchrotron operation. The irradiation efficiency was improved in 154 (57%) of the 271 cases. The irradiation efficiency was reduced in 117 cases because the TW value was insufficient or the function introduced an unutilized wait time for the next gate-on signal in the flat top phase. In the actual treatment of a patient with a hepatic tumor at Tw=0.2s, 4.48GyE irradiation was completed within 250s. In contrast, the treatment time of ordinary synchrotron operation was estimated to be 420s. The results suggest that the multiple gated-irradiation function has potential to improve the gated irradiation efficiency and to reduce the treatment time. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  2. Knowledge rule base for the beam optics program TRACE 3-D

    International Nuclear Information System (INIS)

    Gillespie, G.H.; Van Staagen, P.K.; Hill, B.W.

    1993-01-01

    An expert system type of knowledge rule base has been developed for the input parameters used by the particle beam transport program TRACE 3-D. The goal has been to provide the program's user with adequate on-screen information to allow him to initially set up a problem with minimal open-quotes off-lineclose quotes calculations. The focus of this work has been in developing rules for the parameters which define the beam line transport elements. Ten global parameters, the particle mass and charge, beam energy, etc., are used to provide open-quotes expertclose quotes estimates of lower and upper limits for each of the transport element parameters. For example, the limits for the field strength of the quadrupole element are based on a water-cooled, iron-core electromagnet with dimensions derived from practical engineering constraints, and the upper limit for the effective length is scaled with the particle momenta so that initially parallel trajectories do not cross the axis inside the magnet. Limits for the quadrupole doublet and triplet parameters incorporate these rules and additional rules based on stable FODO lattices and bidirectional focusing requirements. The structure of the rule base is outlined and examples for the quadrupole singlet, doublet and triplet are described. The rule base has been implemented within the Shell for Particle Accelerator Related Codes (SPARC) graphical user interface (GUI)

  3. Electron beam controlled covalent attachment of small organic molecules to graphene.

    Science.gov (United States)

    Markevich, Alexander; Kurasch, Simon; Lehtinen, Ossi; Reimer, Oliver; Feng, Xinliang; Müllen, Klaus; Turchanin, Andrey; Khlobystov, Andrei N; Kaiser, Ute; Besley, Elena

    2016-02-07

    The electron beam induced functionalization of graphene through the formation of covalent bonds between free radicals of polyaromatic molecules and C=C bonds of pristine graphene surface has been explored using first principles calculations and high-resolution transmission electron microscopy. We show that the energetically strongest attachment of the radicals occurs along the armchair direction in graphene to carbon atoms residing in different graphene sub-lattices. The radicals tend to assume vertical position on graphene substrate irrespective of direction of the bonding and the initial configuration. The "standing up" molecules, covalently anchored to graphene, exhibit two types of oscillatory motion--bending and twisting--caused by the presence of acoustic phonons in graphene and dispersion attraction to the substrate. The theoretically derived mechanisms are confirmed by near atomic resolution imaging of individual perchlorocoronene (C24Cl12) molecules on graphene. Our results facilitate the understanding of controlled functionalization of graphene employing electron irradiation as well as mechanisms of attachment of impurities via the processing of graphene nanoelectronic devices by electron beam lithography.

  4. Chaos control in an electron beam with the supercritical current in the hydrodynamic model of the Pierce diode

    International Nuclear Information System (INIS)

    Koronovskij, A.A.; Rempen, I.S.; Khramov, A.E.

    2003-01-01

    The possibility of controlling the chaos in the electron beam with the supercritical current in the hydrodynamic model of the Pierce diode through the continuous feedback; the methodology of controlling the chaotic dynamics through stabilization of the unstable equilibrium state in the distributed active medium is proposed [ru

  5. Calibration of Eringen's small length scale coefficient for initially stressed vibrating nonlocal Euler beams based on microstructured beam model

    International Nuclear Information System (INIS)

    Wang, C M; Zhang, Z; Challamel, N; Duan, W H

    2013-01-01

    In this paper, we calibrate Eringen's small length scale coefficient e 0 for an initially stressed vibrating nonlocal Euler beam via a microstructured beam modelled by some repetitive cells comprising finite rigid segments and elastic rotational springs. By adopting the pseudo-differential operator and Padé's approximation, an analytical solution for the vibration frequency in terms of initial stress may be developed for the microstructured beam model. When comparing this analytical solution with the established exact vibration solution from the nonlocal beam theory, one finds that the calibrated Eringen's small length scale coefficient e 0 is given by e 0 = √(1/6)-(1/12)(σ 0 /σ-breve m ) where σ 0 is the initial stress and σ-breve m is the mth mode buckling stress of the corresponding local Euler beam. It is shown that e 0 varies with respect to the initial axial stress, from 1/√(12)∼0.289 at the buckling compressive stress to 1/√6∼0.408 when the axial stress is zero and it monotonically increases with increasing initial tensile stress. The small length scale coefficient e 0 , however, does not depend on the vibration/buckling mode considered. (paper)

  6. A method of beam control for NFZ-10 industrial irradiation linac

    International Nuclear Information System (INIS)

    Zhao Minghua

    2000-01-01

    Traditionally negative feedback coming from output beam is used to stabilize output beam by regulating filament voltage of bombarding diode electron gun. The authors analysed the shortcomings of the method in detail and put forward a new method of regulating bombarding high voltage in NFZ-10 industrial irradiation linac. Output beam with high stability and high accuracy was obtained

  7. Control of electron beam by using high-Z gas target in the laser-plasma acceleration

    International Nuclear Information System (INIS)

    Mori, Michiaki

    2012-01-01

    We investigate the pointing stability and the divergence of a quasi-monoenergetic electron beam generated in a self-injected laser-plasma acceleration regime using high-Z gas-jet target. Gas-jet targets have been irradiated with focused 40 fs laser pulses at the 4-TW peak power. A pointing stability and a beam divergence of electron beam were improved using argon target. These values were about three times smaller than at the optimum condition using helium. This stabilization method is available for another gas material such as nitrogen. At nitrogen gas-jet target, the pointing stability is more improved to two times smaller than that in argon gas-jet target and the peak energy is increased to >30 MeV. These results prove that this method not only stabilizes the e-beam but also allows controlling the electron energy. (author)

  8. Automated beam placement for breast radiotherapy using a support vector machine based algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Zhao Xuan; Kong, Dewen; Jozsef, Gabor; Chang, Jenghwa; Wong, Edward K.; Formenti, Silvia C.; Wang Yao [Department of Electrical and Computer Engineering, Polytechnic Institute of New York University, Brooklyn, New York 11201 (United States); Department of Radiation Oncology, School of Medicine, Langone Medical Center, New York University, New York, New York 10016 (United States); Department of Computer Science and Engineering, Polytechnic Institute of New York University, Brooklyn, New York 11201 (United States); Department of Radiation Oncology, School of Medicine, Langone Medical Center, New York University, New York, New York 10016 (United States); Department of Electrical and Computer Engineering, Polytechnic Institute of New York University, Brooklyn, New York 11201 (United States)

    2012-05-15

    Purpose: To develop an automated beam placement technique for whole breast radiotherapy using tangential beams. We seek to find optimal parameters for tangential beams to cover the whole ipsilateral breast (WB) and minimize the dose to the organs at risk (OARs). Methods: A support vector machine (SVM) based method is proposed to determine the optimal posterior plane of the tangential beams. Relative significances of including/avoiding the volumes of interests are incorporated into the cost function of the SVM. After finding the optimal 3-D plane that separates the whole breast (WB) and the included clinical target volumes (CTVs) from the OARs, the gantry angle, collimator angle, and posterior jaw size of the tangential beams are derived from the separating plane equation. Dosimetric measures of the treatment plans determined by the automated method are compared with those obtained by applying manual beam placement by the physicians. The method can be further extended to use multileaf collimator (MLC) blocking by optimizing posterior MLC positions. Results: The plans for 36 patients (23 prone- and 13 supine-treated) with left breast cancer were analyzed. Our algorithm reduced the volume of the heart that receives >500 cGy dose (V5) from 2.7 to 1.7 cm{sup 3} (p = 0.058) on average and the volume of the ipsilateral lung that receives >1000 cGy dose (V10) from 55.2 to 40.7 cm{sup 3} (p = 0.0013). The dose coverage as measured by volume receiving >95% of the prescription dose (V95%) of the WB without a 5 mm superficial layer decreases by only 0.74% (p = 0.0002) and the V95% for the tumor bed with 1.5 cm margin remains unchanged. Conclusions: This study has demonstrated the feasibility of using a SVM-based algorithm to determine optimal beam placement without a physician's intervention. The proposed method reduced the dose to OARs, especially for supine treated patients, without any relevant degradation of dose homogeneity and coverage in general.

  9. Evaluation of a GEM and CAT-based detector for radiation therapy beam monitoring

    International Nuclear Information System (INIS)

    Brahme, A.; Danielsson, M.; Iacobaeus, C.; Ostling, J.; Peskov, V.; Wallmark, M.

    2000-01-01

    We are developing a radiation therapy beam monitor for the Karolinska Institute. This monitor will consist of two consecutive detectors confined in one gas chamber: a 'keV-photon detector', which will allow diagnostic quality visualization of the patient, and a 'MeV-photon detector', that will measure the absolute intensity of the therapy beam and its position with respect to the patient. Both detectors are based on highly radiation resistant gas and solid photon to electron converters, combined with GEMs and a CAT as amplification structures. We have performed systematic studies of the high-rate characteristics of the GEM and the CAT, as well as tested the electron transfer through these electron multipliers and various types of converters. The tests show that the GEM and the CAT satisfy all requirements for the beam monitoring system. As a result of these studies we successfully developed and tested a full section of the beam monitor equipped with a MeV-photon converter placed between the GEM and the CAT

  10. Analyses of a cantilever-beam based instrument for evaluating the development of polymerization stresses.

    Science.gov (United States)

    Chiang, Martin Y M; Giuseppetti, Anthony A M; Qian, Jing; Dunkers, Joy P; Antonucci, Joseph M; Schumacher, Gary E; Gibson, Sheng-Lin

    2011-09-01

    This investigation was to generate (1) guidelines for designing a tensometer that satisfies the necessary accuracy and sensitivity requirements for measuring polymerization stress (PS), and (2) a formula for calculating PS. Polymerization stress remains one of the most critical properties of polymeric dental materials, yet methods that can accurately quantify PS have been limited in part due to the complexity of polymerization, and in part due to the instrumentation itself. In this study, we performed analytical and finite element analyses on a cantilever-beam based tensometer that is used to evaluate shrinkage stresses during the polymerization of dental restorative composites. The PS generated by a commercial dental composite determined using our new tensometer agrees with the predicted trend when the beam length and/or specimen height is varied. This work demonstrates the importance of beam dimension and component relative rigidity to the accuracy of PS evaluation. An analytical solution is also derived for the vertical beam deflection, which can be used for any combination of bending and shearing to properly calculate the PS. In addition, an easy-to-conduct calibration procedure is provided that is desirable for periodic tensometer recalibration. Published by Elsevier Ltd.

  11. Fabrication of phonon-based metamaterial structures using focused ion beam patterning

    Science.gov (United States)

    Bassim, Nabil D.; Giles, Alexander J.; Ocola, Leonidas E.; Caldwell, Joshua D.

    2018-02-01

    The focused ion beam (FIB) is a powerful tool for rapid prototyping and machining of functional nanodevices. It is employed regularly to fabricate test metamaterial structures but, to date, has been unsuccessful in fabricating metamaterial structures with features at the nanoscale that rely on surface phonons as opposed to surface plasmons because of the crystalline damage that occurs with the collision cascade associated with ion sputtering. In this study, we employ a simple technique of protecting the crystalline substrate in single-crystal 4H-SiC to design surface phonon polariton-based optical resonance structures. By coating the material surface with a thin film of chromium, we have placed a material of high sputter resistance on the surface, which essentially absorbs the energy in the beam tails. When the beam ultimately punches through the Cr film, the hard walls in the film have the effect of channeling the beam to create smooth sidewalls. This demonstration opens the possibility of further rapid-prototyping of metamaterials using FIB.

  12. Beam-hardening correction in CT based on basis image and TV model

    International Nuclear Information System (INIS)

    Li Qingliang; Yan Bin; Li Lei; Sun Hongsheng; Zhang Feng

    2012-01-01

    In X-ray computed tomography, the beam hardening leads to artifacts and reduces the image quality. It analyzes how beam hardening influences on original projection. According, it puts forward a kind of new beam-hardening correction method based on the basis images and TV model. Firstly, according to physical characteristics of the beam hardening an preliminary correction model with adjustable parameters is set up. Secondly, using different parameters, original projections are operated by the correction model. Thirdly, the projections are reconstructed to obtain a series of basis images. Finally, the linear combination of basis images is the final reconstruction image. Here, with total variation for the final reconstruction image as the cost function, the linear combination coefficients for the basis images are determined according to iterative method. To verify the effectiveness of the proposed method, the experiments are carried out on real phantom and industrial part. The results show that the algorithm significantly inhibits cup and strip artifacts in CT image. (authors)

  13. Development of plant-based resist materials in electron beam lithography

    Science.gov (United States)

    Takei, Satoshi; Oshima, Akihiro; Yanamori, Naomi; Sekiguchi, Atsushi; Kozawa, Takahiro; Tagawa, Seiichi

    2011-04-01

    Electron beam lithography has great potential for future production of nano-imprint templates, light-emitting diodes, solar cell devices, actuators, biosensors, and micro electro mechanical systems (MEMS) where continued success ultimately requires improvements in current processing technologies. Electron beam lithography is promising for advancing multiple electronic applications due to several advantages such as high resolution, deep depth of focus, flexibility in material design, and assumable cost. This study presents progress in the development of a new plant-based resist material (TPU-EBR1) to achieve high exposure sensitivity and lower film thickness shrinkage by electron beam irradiation. Highly efficient crosslinking properties and high quality patterning line images were provided by specific process conditions of 30 keV electron beam lithography. Lower film thickness shrinkage of the newly developed TPU-EBR than that of the referenced acrylate type resist material is one of key to achieve EB patterning. The validity of our approach using the developed TPU-EBR was confirmed experimentally. In addition, this new approach was demonstrated to apply glucose and dextrin derivatives as the eco-friendlier compounds to the resist materials in micro and nano-patterning processes for environmentally-compatible electronic device fabrications.

  14. A node-based smoothed point interpolation method for dynamic analysis of rotating flexible beams

    Science.gov (United States)

    Du, C. F.; Zhang, D. G.; Li, L.; Liu, G. R.

    2017-10-01

    We proposed a mesh-free method, the called node-based smoothed point interpolation method (NS-PIM), for dynamic analysis of rotating beams. A gradient smoothing technique is used, and the requirements on the consistence of the displacement functions are further weakened. In static problems, the beams with three types of boundary conditions are analyzed, and the results are compared with the exact solution, which shows the effectiveness of this method and can provide an upper bound solution for the deflection. This means that the NS-PIM makes the system soften. The NS-PIM is then further extended for solving a rigid-flexible coupled system dynamics problem, considering a rotating flexible cantilever beam. In this case, the rotating flexible cantilever beam considers not only the transverse deformations, but also the longitudinal deformations. The rigid-flexible coupled dynamic equations of the system are derived via employing Lagrange's equations of the second type. Simulation results of the NS-PIM are compared with those obtained using finite element method (FEM) and assumed mode method. It is found that compared with FEM, the NS-PIM has anti-ill solving ability under the same calculation conditions.

  15. Damage detection in multi-span beams based on the analysis of frequency changes

    International Nuclear Information System (INIS)

    Gillich, G R; Ntakpe, J L; Praisach, Z I; Mimis, M C; Abdel Wahab, M

    2017-01-01

    Crack identification in multi-span beams is performed to determine whether the structure is healthy or not. Among all crack identification methods, these based on measured natural frequency changes present the advantage of simplicity and easy to use in practical engineering. To accurately identify the cracks characteristics for multi-span beam structure, a mathematical model is established, which can predict frequency changes for any boundary conditions, the intermediate supports being hinges. This relation is based on the modal strain energy concept. Since frequency changes are relative small, to obtain natural frequencies with high resolution, a signal processing algorithm based on superposing of numerous spectra is also proposed, which overcomes the disadvantage of Fast Fourier Transform in the aspect of frequency resolution. Based on above-mentioned mathematical model and signal processing algorithm, the method of identifying cracks on multi-span beams is presented. To verify the accuracy of this identification method, experimental examples are conducted on a two-span structure. The results demonstrate that the method proposed in this paper can accurately identify the crack position and depth. (paper)

  16. Near-diffraction-limited segmented broad area diode laser based on off-axis spectral beam combining

    DEFF Research Database (Denmark)

    Jensen, O.B.; Thestrup Nielsen, Birgitte; Andersen, Peter E.

    2006-01-01

    The beam quality of a 500-mu m-wide broad area diode laser with five active segments has been improved beyond the beam quality of the individual segments. The principle of this new laser system is based on off-axis feedback in combination with spectral beam combining. By using a double......-feedback scheme we are able to improve the beam quality of the laser by a factor of 23 from M-2 = 55 for the free-running diode laser to M-2 = 2.4 for the laser with feedback at a drive current of 2.2 A. The improved M-2 value is a factor of 3.4 below M-2 = 8.2 for a single free-running segment. This is the first...... time that the beam quality of a segmented broad area diode laser has been improved beyond the beam quality of the individual segments....

  17. The earthing system of the PRIMA Neutral Beam Test Facility based on the Mesh Common Bonding Network topology

    International Nuclear Information System (INIS)

    Pomaro, Nicola; Boldrin, Marco; Lazzaro, Gabriele

    2015-01-01

    Highlights: • We designed a high performance earthing system for the ITER Neutral Beam Test Facility. • The system is based on the Mesh Common Bonded Network topology. • Careful bonding of all metallic structures allowed to obtain a well meshed system. • Special care was dedicated to improve EMC performance of critical areas like control rooms. • The facility experimental results will be representative also of the ITER situation. - Abstract: PRIMA is a large experimental facility under realization in Padova, aimed at developing and testing the Neutral Beam Injectors for ITER. The operation of these devices involves high RF power and voltage up to 1 MV. Frequent and high voltage electrical breakdowns inside the beam sources occur regularly. The presence of a distributed carefully optimized earthing system is of paramount importance to achieve a satisfying disturbances immunity for equipment and diagnostics. The paper describes the design and the realization of the earthing system of the PRIMA facility, which is based on the MESH-Common Bonding Network (MESH-CBN) topology, as recommended by IEC and IEEE standards for installations with high levels of Electromagnetic Interferences (EMI). The principles of the MESH-CBN approach were adapted to the PRIMA layout, which is composed by several buildings, that are independent for seismic and architectural reasons, but are linked by many electrical conduits and hydraulic pipelines. The availability of huge foundations, with a large number of poles and pillars, was taken into account; building parts dedicated to host control rooms and sensitive equipment were treated with particular care. Moreover, the lightning protection system was integrated and harmonized with the earthing system.

  18. Progress of the Hard-wired Instrumentation and Control Works for the Neutral Beam Test Stand at KAERI

    International Nuclear Information System (INIS)

    Jung, Ki Sok

    2005-12-01

    Progress of the hard-wired instrumentation and control works for the neutral beam test stand(NB-TS) has been existed for the past one year period. Details of the installed arc detector circuit are explained. LN 2 level and temperature control during the cryosorption pumping operation are explained with an emphasis on its control circuit. With an expectation of more accurate and sensitive measurement of temperatures than the thermocouple utilization during the calorimeter operation, PT-100 resistance temperature detector(RTD) utilization is initiated and the results are described. During the ion beam experiment, physical measurements are made with some delayed time than the beam extraction, and thus a delayed trigger pulse generator was fabricated and installed to the system. Underlying principles of the electronic circuits for the interlock implementation and optical signal transmission are introduced. These are basically the application of operational amplifier circuits. A cautious aspect of the SMPS(switch mode power supply) utilization is also give

  19. THE AGS-BASED SUPER NEUTRINO BEAM FACILITY CONCEPTUAL DESIGN REPORT

    Energy Technology Data Exchange (ETDEWEB)

    WENG,W.T.; DIWAN,M.; RAPARIA,D.

    2004-10-08

    After more than 40 years of operation, the AGS is still at the heart of the Brookhaven hadron accelerator complex. This system of accelerators presently comprises a 200 MeV linac for the pre-acceleration of high intensity and polarized protons, two Tandem Van der Graaffs for the pre-acceleration of heavy ion beams, a versatile Booster that allows for efficient injection of all three types of beams into the AGS and, most recently, the two RHIC collider rings that produce high luminosity heavy ion and polarized proton collisions. For several years now, the AGS has held the world intensity record with more than 7 x 10{sup 13} protons accelerated in a single pulse. The requirements for the proton beam for the super neutrino beam are summarized and a schematic of the upgraded AGS is shown. Since the present number of protons per fill is already close to the required number, the upgrade is based on increasing the repetition rate and reducing beam losses (to avoid excessive shielding requirements and to maintain activation of the machine components at workable level). It is also important to preserve all the present capabilities of the AGS, in particular its role as injector to RHIC. The AGS Booster was built not only to allow the injection of any species of heavy ion into the AGS but to allow a fourfold increase of the AGS intensity. It is one-quarter the circumference of the AGS with the same aperture. However, the accumulation of four Booster loads in the AGS takes about 0.6 s, and is therefore not well suited for high average beam power operation. To minimize the injection time to about 1 ms, a 1.2 GeV linac will be used instead. This linac consists of the existing warm linac of 200 MeV and a new superconducting linac of 1.0 GeV. The multi-turn H{sup -} injection from a source of 30 mA and 720 {micro}s pulse width is sufficient to accumulate 9 x 10{sup 13} particle per pulse in the AGS[10]. The minimum ramp time of the AGS to full energy is presently 0.5 s; this must

  20. Control of stopping position of radioactive ion beam in superfluid helium for laser spectroscopy experiments

    Energy Technology Data Exchange (ETDEWEB)

    Yang, X.F., E-mail: yangxf@ribf.riken.jp [School of Physics, Peking University, Chengfu Road, Haidian District, Beijing 100871 (China); RIKEN Nishina Center, 2-1 Hirosawa, Wako, Saitama 351-0198 (Japan); Furukawa, T. [Dept. of Physics, Tokyo Metropolitan University, 1-1 Minami-Osawa, Hachioji, Tokyo 192-0397 (Japan); Wakui, T. [Cyclotron and Radioisotope Center Tohoku University, 6-3 Aoba, Aramaki, Aoba-ku, Sendai, Miyagi 980-8578 (Japan); Imamura, K. [Dept. of Physics, Meiji University, 1-1-1 Higashi-Mita, Tama-ku, Kawasaki, Kanagawa 214-8571 (Japan); Tetsuka, H. [Dept. of Physics, Tokyo Gakugei University, 4-1-1 Nukuikitamachi, Koganei, Tokyo 184-8501 (Japan); Fujita, T. [Dept. of Physics, Osaka University, 1-1 Machikaneyama, Toyonaka, Osaka 560-0043 (Japan); Yamaguchi, Y. [Dept. of Physics, Meiji University, 1-1-1 Higashi-Mita, Tama-ku, Kawasaki, Kanagawa 214-8571 (Japan); Tsutsui, Y. [Dept. of Physics, Tokyo Gakugei University, 4-1-1 Nukuikitamachi, Koganei, Tokyo 184-8501 (Japan); Mitsuya, Y. [Dept. of Physics, Meiji University, 1-1-1 Higashi-Mita, Tama-ku, Kawasaki, Kanagawa 214-8571 (Japan); Ichikawa, Y. [Dept. of Physics, Tokyo Institute of Technology, 2-12-1 O-Okayama, Meguro, Tokyo152-8551 (Japan); Ishibashi, Y. [RIKEN Nishina Center, 2-1 Hirosawa, Wako, Saitama 351-0198 (Japan); Dept. of Physics, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8571 (Japan); Yoshida, N.; Shirai, H. [Dept. of Physics, Tokyo Institute of Technology, 2-12-1 O-Okayama, Meguro, Tokyo152-8551 (Japan); Ebara, Y.; Hayasaka, M. [Dept. of Physics, Tokyo Gakugei University, 4-1-1 Nukuikitamachi, Koganei, Tokyo 184-8501 (Japan); Arai, S.; Muramoto, S. [Dept. of Physics, Meiji University, 1-1-1 Higashi-Mita, Tama-ku, Kawasaki, Kanagawa 214-8571 (Japan); Hatakeyama, A. [Dept. of Applied Physics, Tokyo University of Agriculture and Technology, 2-24-16 Naka-cho, Koganei, Tokyo 184-8588 (Japan); Wada, M.; Sonoda, T. [RIKEN Nishina Center, 2-1 Hirosawa, Wako, Saitama 351-0198 (Japan); and others

    2013-12-15

    In order to investigate the structure of exotic nuclei with extremely low yields by measuring nuclear spins and moments, a new laser spectroscopy technique – “OROCHI” (Optical Radioisotopes Observation in Condensed Helium as Ion-catcher) has been proposed in recent years. The feasibility of this technique has been demonstrated by means of a considerable amount of offline and online studies of various atoms in superfluid helium. For in-situ laser spectroscopy of atoms in He II, trapping atoms in the observation region of laser is a key step. Therefore, a method which enables us to trap accelerated atoms at a precise position in He II is highly needed for performing experiment. In this work, a technique making use of a degrader, two plastic scintillators and a photon detection system is established for checking the stopping position of beam based on the LISE++ calculation. The method has been tested and verified by on-line experiments with the {sup 84,85,87}Rb beam. Details of the experimental setup, working procedure and testing results of this method are presented.